Science.gov

Sample records for 3he ionization chambers

  1. Fast-Neutron Spectrometry Using a 3He Ionization Chamber and Digital Pulse Shape Analysis

    SciTech Connect

    D. L. Chichester; J. T. Johnson; E. H. Seabury

    2010-05-01

    Digital pulse shape analysis (dPSA) has been used with a Cuttler-Shalev type 3He proportional counter to measure the fast neutron spectra of bare 252Cf and 241AmBe neutron sources. Measurements have also been made to determine the attenuated fast neutron spectra of 252Cf shielded by several materials including water, graphite, liquid nitrogen, magnesium, and tungsten. Rise-time dPSA has been employed using the common rise-time approach for analyzing n +3He ? 1H + 3H ionization events and a new approach has been developed to improve the fidelity of these measurements. Simulations have been performed for the different experimental arrangements and are compared, demonstrating general agreement between the dPSA processed fast neutron spectra and predictions.

  2. IONIZATION CHAMBER

    DOEpatents

    Redman, W.C.; Shonka, F.R.

    1958-02-18

    This patent describes a novel ionization chamber which is well suited to measuring the radioactivity of the various portions of a wire as the wire is moved at a uniform speed, in order to produce the neutron flux traverse pattern of a reactor in which the wire was previously exposed to neutron radiation. The ionization chamber of the present invention is characterized by the construction wherein the wire is passed through a tubular, straight electrode and radiation shielding material is disposed along the wire except at an intermediate, narrow area where the second electrode of the chamber is located.

  3. Ionization chamber

    DOEpatents

    Walenta, Albert H.

    1981-01-01

    An ionization chamber has separate drift and detection regions electrically isolated from each other by a fine wire grid. A relatively weak electric field can be maintained in the drift region when the grid and another electrode in the chamber are connected to a high voltage source. A much stronger electric field can be provided in the detection region by connecting wire electrodes therein to another high voltage source. The detection region can thus be operated in a proportional mode when a suitable gas is contained in the chamber. High resolution output pulse waveforms are provided across a resistor connected to the detection region anode, after ionizing radiation enters the drift region and ionize the gas.

  4. Ionization chamber

    DOEpatents

    Walenta, A.H.

    An ionization chamber is described which has separate drift and detection regions electrically isolated from each other by a fine wire grid. A relatively weak electric field can be maintained in the drift region when the grid and another electrode in the chamber are connected to a high voltage source. A much stronger electric field can be provided in the detection region by connecting wire electrodes therein to another high voltage source. The detection region can thus be operated in a proportional mode when a suitable gas is contained in the chamber. High resolution output pulse waveforms are provided across a resistor connected to the detection region anode, after ionizing radiation enters the drift region and ionizes the gas.

  5. Multi-anode ionization chamber

    DOEpatents

    Bolotnikov, Aleksey E.; Smith, Graham; Mahler, George J.; Vanier, Peter E.

    2010-12-28

    The present invention includes a high-energy detector having a cathode chamber, a support member, and anode segments. The cathode chamber extends along a longitudinal axis. The support member is fixed within the cathode chamber and extends from the first end of the cathode chamber to the second end of the cathode chamber. The anode segments are supported by the support member and are spaced along the longitudinal surface of the support member. The anode segments are configured to generate at least a first electrical signal in response to electrons impinging thereon.

  6. Ionization-chamber smoke detector system

    DOEpatents

    Roe, Robert F.

    1976-10-19

    This invention relates to an improved smoke-detection system of the ionization-chamber type. In the preferred embodiment, the system utilizes a conventional detector head comprising a measuring ionization chamber, a reference ionization chamber, and a normally non-conductive gas triode for discharging when a threshold concentration of airborne particulates is present in the measuring chamber. The improved system is designed to reduce false alarms caused by fluctuations in ambient temperature. Means are provided for periodically firing the gas discharge triode and each time recording the triggering voltage required. A computer compares each triggering voltage with its predecessor. The computer is programmed to energize an alarm if the difference between the two compared voltages is a relatively large value indicative of particulates in the measuring chamber and to disregard smaller differences typically resulting from changes in ambient temperature.

  7. The GODDESS ionization chamber: developing robust windows

    NASA Astrophysics Data System (ADS)

    Blanchard, Rose; Baugher, Travis; Cizewski, Jolie; Pain, Steven; Ratkiewicz, Andrew; Goddess Collaboration

    2015-10-01

    Reaction studies of nuclei far from stability require high-efficiency arrays of detectors and the ability to identify beam-like particles, especially when the beam is a cocktail beam. The Gammasphere ORRUBA Dual Detectors for Experimental Structure Studies (GODDESS) is made up of the Oak Ridge-Rutgers University Barrel Array (ORRUBA) of silicon detectors for charged particles inside of the gamma-ray detector array Gammasphere. A high-rate ionization chamber is being developed to identify beam-like particles. Consisting of twenty-one alternating anode and cathode grids, the ionization chamber sits downstream of the target chamber and is used to measure the energy loss of recoiling ions. A critical component of the system is a thin and robust mylar window which serves to separate the gas-filled ionization chamber from the vacuum of the target chamber with minimal energy loss. After construction, windows were tested to assure that they would not break below the required pressure, causing harm to the wire grids. This presentation will summarize the status of the ionization chamber and the results of the first tests with beams. This work is supported in part by the U.S. Department of Energy and National Science Foundation.

  8. Making MUSIC: A multiple sampling ionization chamber

    NASA Astrophysics Data System (ADS)

    Shumard, B.; Henderson, D. J.; Rehm, K. E.; Tang, X. D.

    2007-08-01

    A multiple sampling ionization chamber (MUSIC) was developed for use in conjunction with the Atlas scattering chamber (ATSCAT). This chamber was developed to study the (α, p) reaction in stable and radioactive beams. The gas filled ionization chamber is used as a target and detector for both particles in the outgoing channel (p + beam particles for elastic scattering or p + residual nucleus for (α, p) reactions). The MUSIC detector is followed by a Si array to provide a trigger for anode events. The anode events are gated by a gating grid so that only (α, p) reactions where the proton reaches the Si detector result in an anode event. The MUSIC detector is a segmented ionization chamber. The active length of the chamber is 11.95 in. and is divided into 16 equal anode segments (3.5 in. × 0.70 in. with 0.3 in. spacing between pads). The dead area of the chamber was reduced by the addition of a Delrin snout that extends 0.875 in. into the chamber from the front face, to which a mylar window is affixed. 0.5 in. above the anode is a Frisch grid that is held at ground potential. 0.5 in. above the Frisch grid is a gating grid. The gating grid functions as a drift electron barrier, effectively halting the gathering of signals. Setting two sets of alternating wires at differing potentials creates a lateral electric field which traps the drift electrons, stopping the collection of anode signals. The chamber also has a reinforced mylar exit window separating the Si array from the target gas. This allows protons from the (α, p) reaction to be detected. The detection of these protons opens the gating grid to allow the drift electrons released from the ionizing gas during the (α, p) reaction to reach the anode segment below the reaction.

  9. A model for electron/ion recombination in ionization chambers

    SciTech Connect

    Sailor, W.C.

    1988-05-01

    The recombination of free electrons and positive ions along charged particle tracks in gases has been modeled using electron tranport equations, which assume homogeneous distribution in the vicinity of the tracks. The equations include space charge terms, which have been negelected in previous models. A formula for the electron yield as a function of detector applied potential is obtained from a perturbation solution valid when the ratio of the Debye length to the charge column radius is larger then unity. When this ratio is very large, the formula reduces to that of previous models. Pulse height measurements in a /sup 3/He ionization chamber indicate 2% to 30% losses to recombination which vary with applied field, particle type, and energy. Using reasonable values for the electron transport coefficients, the calculated loss of signal to recommendation is generally in agreement with experiment, but the variation with applied bias is stronger in the experiment.

  10. Nuclear Fission Investigation with Twin Ionization Chamber

    SciTech Connect

    Zeynalova, O.; Zeynalov, Sh.; Nazarenko, M.; Hambsch, F.-J.; Oberstedt, S.

    2011-11-29

    The purpose of the present paper was to report the recent results, obtained in development of digital pulse processing mathematics for prompt fission neutron (PFN) investigation using twin ionization chamber (TIC) along with fast neutron time-of-flight detector (ND). Due to well known ambiguities in literature (see refs. [4, 6, 9 and 11]), concerning a pulse induction on TIC electrodes by FF ionization, we first presented detailed mathematical analysis of fission fragment (FF) signal formation on TIC anode. The analysis was done using Ramo-Shockley theorem, which gives relation between charged particle motion between TIC electrodes and so called weighting potential. Weighting potential was calculated by direct numerical solution of Laplace equation (neglecting space charge) for the TIC geometry and ionization, caused by FF. Formulae for grid inefficiency (GI) correction and digital pulse processing algorithms for PFN time-of-flight measurements and pulse shape analysis are presented and discussed.

  11. Characterization of a homemade ionization chamber for radiotherapy beams.

    PubMed

    Neves, Lucio P; Perini, Ana P; dos Santos, Gelson P; Xavier, Marcos; Khoury, Helen J; Caldas, Linda V E

    2012-07-01

    A homemade cylindrical ionization chamber was studied for routine use in therapy beams of (60)Co and X-rays. Several characterization tests were performed: leakage current, saturation, ion collection efficiency, polarity effect, stability, stabilization time, chamber orientation and energy dependence. All results obtained were within international recommendations. Therefore the homemade ionization chamber presents usefulness for routine dosimetric procedures in radiotherapy beams. PMID:22153889

  12. Development of an optical digital ionization chamber

    SciTech Connect

    Turner, J.E.; Hunter, S.R.; Hamm, R.N.; Wright, H.A.; Hurst, G.S.; Gibson, W.A.

    1988-01-01

    We are developing a new device for optically detecting and imaging the track of a charged particle in a gas. The electrons in the particle track are made to oscillate rapidly by the application of an external, short-duration, high-voltage, RF electric field. The excited electrons produce additional ionization and electronic excitation of the gas molecules in their immediate vicinity, leading to copious light emission (fluorescence) from the selected gas, allowing the location of the electrons along the track to be determined. Two digital cameras simultaneously scan the emitted light across two perpendicular planes outside the chamber containing gas. The information thus obtained for a given track can be used to infer relevant quantities for microdosimetry and dosimetry, e.g., energy deposited, LET, and track structure in the gas. The design of such a device now being constructed and methods of obtaining the dosimetric data from the digital output will be described. 4 refs., 4 figs.

  13. A new ring-shaped graphite monitor ionization chamber

    NASA Astrophysics Data System (ADS)

    Yoshizumi, M. T.; Caldas, L. V. E.

    2010-07-01

    A ring-shaped monitor ionization chamber was developed at the Instituto de Pesquisas Energéticas e Nucleares. This ionization chamber presents an entrance window of aluminized polyester foil. The guard ring and collecting electrode are made of graphite coated Lucite plates. The main difference between this new ionization chamber and commercial monitor chambers is its ring-shaped design. The new monitor chamber has a central hole, allowing the passage of the direct radiation beam without attenuation; only the penumbra radiation is measured by the sensitive volume. This kind of ionization chamber design has already been tested, but using aluminium electrodes. By changing the electrode material from aluminium to a graphite coating, an improvement in the chamber response stability was expected. The pre-operational tests, as saturation curve, recombination loss and polarity effect showed satisfactory results. The repeatability and the long-term stability tests were also evaluated, showing good agreement with international recommendations.

  14. A Fast Ionization Chamber for GODDESS

    NASA Astrophysics Data System (ADS)

    Lumb, R. T.; Lipman, A. S.; Baugher, T.; Cizewski, J. A.; Ratkiewicz, A.; Pain, S. D.; Kozub, R. L.

    2014-09-01

    Transfer reactions are among the main methods used in nuclear physics to probe the structure of nuclei. Such information is needed to constrain nuclear models and to understand various nucleosynthesis processes. In many cases, the nuclear level densities are too high to be resolved in transfer reactions via charged particle detection alone. This problem and issues arising from contaminants in radioactive beams can be addressed by using particle- γ coincidence techniques along with heavy recoil identification in inverse kinematics. A device to accomplish these tasks is Gammasphere ORRUBA: Dual Detectors for Experimental Structure Studies (GODDESS), currently being commissioned for the ATLAS facility at ANL. We are currently building a compact, tilted grid ionization chamber for GODDESS to detect and identify beam-like recoils near zero degrees in the lab. The tilt (30 degrees off normal to the beam) helps the ion pairs to be detected quickly, after drifting only a short distance away from the beam axis. This reduces the response time, allowing counting rates of ~500,000/s. The design and current status of the project will be presented. Research supported by the U. S. DOE.

  15. The n3He Experiment: Current Status

    NASA Astrophysics Data System (ADS)

    McCrea, Mark; n3He Collaboration

    2014-09-01

    The n3He experiment aims to make a high precision measurement of the hadronic weak interaction in the reaction n-> +3 He --> p + T by measuring the parity violating asymmetry in the direction of proton emission relative to the neutron polarization direction. As the weak interaction is the only interaction to violate parity this allows us to extract the much smaller weak interaction effects from the larger strong interaction effects. The range of the asymmetry is estimated to be (- 9 . 5 --> 2 . 5) ×10-8 . The goal is to measure this asymmetry with an accuracy of 2 ×10-8 to provide a benchmark for modern effective field theory calculations. n3He will run at the SNS Fundamental Neutron Physics Beamline. The combined target and detector is a multiwire 3He ionization chamber. A super mirror polarizer will be used to polarize the incoming cold neutron beam, and a spin flipper will reverse the spin in a sequence to control for systematic effects.

  16. The Analysis of Ionization Chambers Used for Detecting Smoke Particles

    NASA Astrophysics Data System (ADS)

    Turlej, Z. (Bish).

    Ionization type cells using a radioactive source of primary ions have been used as fire detectors for many years. They have proven sufficiently sensitive to give an alarm when exposed to the relatively small concentration of smoke particles that occur during the early stages of combustion when control of a fire is still possible. In this work the charging of smoke particles in ionization chambers such as typically employed in ionization smoke detectors are investigated theoretically and experimentally. The ionization chambers investigated in this work have parallel plate and spherical electrode geometries. In the absence of smoke particles, the ionization chambers were operated at some ambient electrode current, which depends upon the ion generation rate, the electrode geometries, the potential difference between the electrodes, and the thermodynamic properties of the gas within the chamber volume. When smoke particles are introduced into the ionization chamber they act as an additional sink for the ions, so that the ion current is reduced. The smoke particles in the experiment performed in this work were transferred from the particle generator to the volume surrounding the ionization chamber and allowed to diffuse inside the ionization chamber. An Aitken nuclei counter was employed to measure the concentration of smoke particles inside the ionization chamber. The electric current flowing through the ionization chamber was recorded as a function of time and concentration of the smoke particles inside the chamber. The current loss due to the particles present inside the chamber was calculated and compared with the experimental results. It was found that at the certain level of ambient electrode current, the current loss due to the smoke particles assumes a maximum value. This optimum operating electrode current was predicted by the mathematical model employed in this work. In the light of this model experimental ionization chambers of both parallel and spherical

  17. Radiation damage to tetramethlysilane and tetramethlygermanium ionization chambers

    NASA Astrophysics Data System (ADS)

    Hoshi, Y.; Higuchi, M.; Oyama, K.; Akaishi, H.; Yuta, H.; Abe, K.; Hasegawa, K.; Suekane, F.; Nagamine, T.; Kawamura, N.

    1994-08-01

    Two detector media suitable for a warm liquid, ionization chamber filled with tetramethylsilane(TMS) and tetramethylgermanium(TMG) were exposed to y radiation from a (sup 60)Co source up to dose 579Gray and 902Gray, respectively. The electron lifetimes and the free ion yields were measured as a function of accumulated radiation dose. A similar behavior of the electron lifetimes and the free ion yields with increasing radiation dose was observed between the TMS and TMG ionization chambers.

  18. RADIATION MONITOR CONTAINING TWO CONCENTRIC IONIZATION CHAMBERS AND MEANS FOR INSULATING THE SEPARATE CHAMBERS

    DOEpatents

    Braestrup, C.B.; Mooney, R.T.

    1964-01-21

    This invention relates to a portable radiation monitor containing two concentric ionization chambers which permit the use of standard charging and reading devices. It is particularly adapted as a personnel x-ray dosimeter and to this end comprises a small thin walled, cylindrical conductor forming an inner energy dependent chamber, a small thin walled, cylindrical conductor forming an outer energy independent chamber, and polymeric insulation means which insulates said chambers from each other and holds the chambers together with exposed connections in a simple, trouble-free, and compact assembly substantially without variation in directional response. (AEC)

  19. Construction and commissioning of a position-sensitive ionization chamber

    NASA Astrophysics Data System (ADS)

    Kwag, M. S.; Chae, K. Y.; Cha, S. M.; Kim, A.; Kim, M. J.; Lee, E. J.; Lee, J. H.

    2016-05-01

    A position-sensitive ionization chamber has been constructed and commissioned at the Physics Department of Sungkyunkwan University to extract position information on incident charged particles for future nuclear reaction measurements. By utilizing the newly-designed position-sensitive anodes and the previously-commissioned portable gas-filled ionization chamber by Chae et al., position information on incident particles could be obtained. The device was tested with an 241Am α-emitting source, and the standard deviation of the fitted Gaussian distribution was measured to be 1.76 mm when a collimator with a 2 mm hole was used.

  20. The response of ionization chambers to relativistic heavy nuclei

    NASA Technical Reports Server (NTRS)

    Newport, B. J.; Stone, E. C.; Waddington, C. J.; Binns, W. R.; Fixsen, D. J.; Garrard, T. L.; Grimm, G.; Israel, M. H.; Klarmann, J.

    1985-01-01

    The LBL Bevalac for the Heavy Nuclei Experiment on HEAO-3, compared the response of a set of laboratory ionization chambers to beams of 26Fe, 36Kr, 54Xe, 67 Ho, and 79Au nuclei at maximum energies ranging from 1666 MeV/amu for Fe to 1049 MeV/amu for Au. The response of these chambers shows a significant deviation from the expected energy dependence, but only a slight deviation from Z sq scaling.

  1. Direct experimental determination of Frisch grid inefficiency in ionization chamber

    NASA Astrophysics Data System (ADS)

    Khriachkov, V. A.; Goverdovski, A. A.; Ketlerov, V. V.; Mitrofanov, V. F.; Semenova, N. N.

    1997-07-01

    The present work describes the method of direct experimental determination of the Frisch grid inefficiency in an ionization chamber. The method is based on analysis of the anode signal after Waveform Digitizer. It is shown that the calculated grid inefficiency value can differ much from the measured ones.

  2. A multiple sampling ionization chamber for the External Target Facility

    NASA Astrophysics Data System (ADS)

    Zhang, X. H.; Tang, S. W.; Ma, P.; Lu, C. G.; Yang, H. R.; Wang, S. T.; Yu, Y. H.; Yue, K.; Fang, F.; Yan, D.; Zhou, Y.; Wang, Z. M.; Sun, Y.; Sun, Z. Y.; Duan, L. M.; Sun, B. H.

    2015-09-01

    A multiple sampling ionization chamber used as a particle identification device for high energy heavy ions has been developed for the External Target Facility. The performance of this detector was tested with a 239Pu α source and RI beams. A Z resolution (FWHM) of 0.4-0.6 was achieved for nuclear fragments of 18O at 400 AMeV.

  3. HPXe ionization chambers for γ spectrometry at room temperature

    NASA Astrophysics Data System (ADS)

    Ottini-Hustache, S.; Monsanglant-Louvet, C.; Haan, S.; Dmitrenko, V.; Grachev, V.; Ulin, S.

    2004-01-01

    High pressure xenon (HPXe) ionization chambers exhibit many characteristics which make them particularly suitable for industrial γ spectrometry at room or higher temperature. The use of a gas as detection medium allows one to reach very large effective volumes and makes these chambers relatively insensitive to radiation damage. Further, the high atomic number of xenon ( Z=54) enhances the total absorption of incident photons and provides, combined to high pressure, a good enough detection efficiency with respect to solid state detectors. Furthermore, such ionization chambers with Frisch grid appear to be very stable over wide periods (e.g. a research prototype has been used aboard MIR orbital station for several years) and temperature range (up to 180°), without maintenance. The characteristics of different prototypes are presented. Their detection efficiency and energy resolution are studied as a function of incident γ ray energy. New developments in electronics and signal processing are also investigated to improve their performances.

  4. The response of ionization chambers to relativistic heavy nuclei

    NASA Technical Reports Server (NTRS)

    Newport, B. J.; Stone, E. C.; Waddington, C. J.; Binns, W. R.; Fixsen, D. J.; Garrard, T. L.; Grimm, G.; Israel, M. H.; Klarmann, J.

    1985-01-01

    As part of a recent calibration at the LBL Bevalac for the Heavy Nuclei Experiment on HEAO-3, the response of a set of laboratory ionization chambers were compared to beams of 26Fe, 36 Kr, 54Xe, 67 Ho, and 79 Au nuclei at maximum energies ranging from 1666 MeV/amu for Fe to 1049 MeV/amu for Au. The response of these chambers shows a significant deviation from the expected energy dependence, but only a slight deviation from Z squared scaling.

  5. Ionization chamber for measurements of high-level tritium gas

    SciTech Connect

    Carstens, D.H.W.; David, W.R.

    1980-01-01

    The construction and calibration of a simple ionization-chamber apparatus for measurement of high level tritium gas is described. The apparatus uses an easily constructed but rugged chamber containing the unknown gas and an inexpensive digital multimeter for measuring the ion current. The equipment after calibration is suitable for measuring 0.01 to 100% tritium gas in hydrogen-helium mixes with an accuracy of a few percent. At both the high and low limits of measurements deviations from the predicted theoretical current are observed. These are briefly discussed.

  6. Ionization chamber response in intensity-modulated radiotherapy beams

    NASA Astrophysics Data System (ADS)

    Markovic, Alexander

    The response of ionization chambers in IMRT fields has been investigated. Differences between measured and calculated values of average chamber dose associated with chamber position, volume averaging and low monitor unit effects were assessed with regards to patient specific IMRT quality assurance (QA). Calculations were performed with a commercially available treatment planning system (TPS). Inaccuracy of chamber positioning during QA was shown to adversely affect measurements due to steep dose gradients in the vicinity of penumbras generated by MLC leaf-tips. The measurement error was inversely related to chamber size. The Exradin A12 chamber showed errors of 4.1% and 9.6% in its short (0.61 cm) and long dimensions (2.2 cm) while the Exradin T14 Microchamber showed an error of 15.4% in its useful dimension (0.1 cm). A QA phantom was designed to improve positional accuracy and reproducibility. Setup reproducibility results showed a standard deviation of 0.93 and 1.1 mm in the longitudinal and lateral directions through the use of this phantom. The effect of leaf shadowing of a measurement chamber during IMRT QA was correlated to the error in point dose results. The error between calculation and measurement increased with a higher degree of chamber shadowing, which indicated that point dose results could be improved by placing the chamber in areas where the effect of shadowing was minimized. A linear systems approach was utilized to determine the chamber response function of three chambers for subsequent implementation in a TPS. Improvement in dose calculation accuracy was expected. The response functions were used in a TPS to design special chambers that had the same averaging properties as exhibited during water phantom measurements. Results were improved over using a chamber represented by a perfect cylinder, but spatial resolution limitations prevented optimal results. Another chamber design that was based on a heuristic approach yielded desired results with

  7. Development of a portable gas-filled ionization chamber

    NASA Astrophysics Data System (ADS)

    Chae, K. Y.; Cha, S. M.; Gwak, M. S.

    2014-02-01

    A new portable gas-filled ionization chamber has been designed and constructed at the Physics Department of Sung Kyun Kwan University. To overcome the maximum count rate of ˜105 particles per second of a conventional ionization chamber, which utilizes a Frisch grid, and to enhance the portability of a detector, we adopted the design of multiple electrodes and modified it from the original designs by Kimura et al. and Chae et al. The new design utilizes a stack of multiple electrodes installed perpendicular to the optical beam axis. This configuration provides a fast response time for the detector, which is essential for high-rate counting. The device has been tested with a 241Am ( t 1/2 = 432.2 years) radioactive α source, which mainly emits 5.486-MeV (branching ratio of 85%) and 5.443-MeV (branching ratio of 13%) α particles. An energy resolution of 6.3% was achieved.

  8. An ionization chamber shower detector for the LHC Luminosity Monitor

    SciTech Connect

    Speziali, V.; Beche, J.F.; Burks, M.T.; Datte, P.S.; Haguenauer, M.; manfredi, P.F.; Millaud, J.E.; Placidi, M.; Ratti, L.; Re, V.; Riot, V.J.; Schmickler, H.; Turner, W.C.

    2000-10-01

    The front IR quadrupole absorbers (TAS) and the IR neutral particle absorbers (TAN) in the high luminosity insertions of the Large Hadron Collider (LHC) each absorb approximately 1.8 TeV of forward collision products on average per pp interaction (~;;235W at design luminosity 1034cm-2s-1). This secondary particle flux can be exploited to provide a useful storage ring operations tool for optimization of luminosity. A novel segmented, multi-gap, pressurized gas ionization chamber is being developed for sampling the energy deposited near the maxima of the hadronic/ electromagnetic showers in these absorbers. The system design choices have been strongly influenced by optimization of signal to noise ratio and by the very high radiation environment. The ionization chambers are instrumented with low noise, fast, pulse shaping electronics to be capable of resolving individual bunch crossings at 40 MHz. Data on each bunch are to be separately accumulated over multiple bunch crossings until the desired statistical accuracy is obtained. At design luminosity approximately 2x103 bunch crossings will suffice for a 1percent luminosity measurement. In this paper we report the first experimental results of the ionization chamber and analog electronics. Single 450GeV protons from the SPS at CERN are used to simulate the hadronic/electromagnetic showers produced by the forward collision products from the interaction regions of the LHC.

  9. Two-dimensional position sensitive ionization chamber with GEM

    NASA Astrophysics Data System (ADS)

    Kitamura, Noritaka; Noro, Tetsuo; Sakaguchi, Satoshi; Takao, Hideaki; Nishio, Yasutaka

    2014-09-01

    We have been developing a multi-anode ionization chamber for Accelerator Mass Spectrometry (AMS) at Kyushu University. Furthermore, we are planning to construct a neutron detector with high position resolution by combining the chamber with Gas Electron Multiplier (GEM) and a neutron converter. One of purposes is the measurement of p-> , pn knockout reaction from unstable nuclei. The multi-anode ionization chamber is composed of subdivided multiple anodes, a cathode to produce an uniform electric field, and a Frisch grid. The chamber must have position sensitivity because obtaining a beam profile is required for AMS measurements, where counting loss should be avoided. Also in the case of the neutron detector, it is necessary to measure the position to deduce the scattering angles. We have recently established a two-dimensional position readout system by the following methods: the measurement of horizontal position is enabled by trimming some anodes into wedge-like shape, and vertical position can be determined by the ratio of induced charge on the grid to the total charge on anodes. In addition, improvement of S/N ratio is important for isotope separation and position resolution. We installed a rectangular-shaped GEM and tried improving S/N ratio by electron amplification.

  10. Development of a multi-anode ionization chamber

    NASA Astrophysics Data System (ADS)

    Makino, Hiroki; Morikawa, Tsuneyasu; Noro, Tetsuo; Maeda, Toyokazu

    2009-10-01

    A multi-anode ionization chamber with a Frisch grid has been developed. An immediate purpose is the use in accelerator mass spectrometry (AMS), but the system will also be applied to measurements in heavy-ion nuclear physics. In order to identify the incident heavy ions, the anode is divided into 16 sections so that the ionization distribution along the ion trajectory (Bragg curve) can be analyzed. Layout of the electrodes, for field shaping, has been determined based on calculations by using a computer code, Poisson-Superfish. A good discrimination of ^36Cl ions from background ^36S ions has been shown by the Monte Carlo simulation. For the signal readout, an originally designed charge-sensitive preamplifier was newly made by using conventional operational amplifiers so as to integrate the ionization charge and interface the shaped signal to the electronic modules of existing data acquisition system. These developments are still in progress. In the meeting, the overall performance of the ionization-chamber system investigated by using accelerated heavy ion beams will be presented.

  11. Response of ionization chamber based pocket dosimeter to beta radiation.

    PubMed

    Kumar, Munish; Gupta, Anil; Pradhan, S M; Bakshi, A K; Chougaonkar, M P; Babu, D A R

    2013-12-01

    Quantitative estimate of the response of ionization chamber based pocket dosimeters (DRDs) to various beta sources was performed. It has been established that the ionization chamber based pocket dosimeters do not respond to beta particles having energy (Emax)<1 MeV and same was verified using (147)Pm, (85)Kr and (204)Tl beta sources. However, for beta particles having energy >1 MeV, the DRDs exhibit measureable response and the values are ~8%, ~14% and ~27% per mSv for natural uranium, (90)Sr/(90)Y and (106)Ru/(106)Rh beta sources respectively. As the energy of the beta particles increases, the response also increases. The response of DRDs to beta particles having energy>1 MeV arises due to the fact that the thickness of the chamber walls is less than the maximum range of beta particles. This may also be one of the reasons for disparity between doses measured with passive/legal dosimeters (TLDs) and DRDs in those situations in which radiation workers are exposed to mixed field of gamma photons and beta particles especially at uranium processing plants, nuclear (power and research) reactors, waste management facilities and fuel reprocessing plants etc. The paper provides the reason (technical) for disparity between the doses recorded by TLDs and DRDs in mixed field of photons and beta particles. PMID:23978508

  12. Developing a fast ionization chamber for transfer reaction studies

    NASA Astrophysics Data System (ADS)

    Chae, K. Y.; Bardayan, D. W.; Smith, M. S.; Schmitt, K. T.; Ahn, S. H.; Peters, W. A.; Strauss, S.

    2011-10-01

    Detection of beam and beam like recoils at far forward angles is often critical for radioactive beam measurements in inverse kinematics. Gas-filled ionization chambers are well suited for these applications, since they have moderately good energy resolution and can take prolonged exposure to beam compared to fragile semiconductor detectors. Conventional ion counters using a Frisch grid, however, have slow response times because the ionized electrons must travel long distances to the anodes. To reduce response times, a fast ion counter using a tilted window and tilted electrodes was developed and tested at ORNL's Holifield Radioactive Ion Beam Facility, modified from an original design by Kimura et al.. The maximum counting rate and energy resolution, along with future plans for using the new ion counter, will be presented. This work was sponsored by the Office of Nuclear Physics, U.S. Department of Energy.

  13. Fast-neutron spectrometry using a ³He ionization chamber and digital pulse shape analysis.

    PubMed

    Chichester, D L; Johnson, J T; Seabury, E H

    2012-08-01

    Digital pulse shape analysis (dPSA) has been used with a Cuttler-Shalev type (3)He ionization chamber to measure the fast-neutron spectra of a deuterium-deuterium electronic neutron generator, a bare (252)Cf spontaneous fission neutron source, and of the transmitted fast neutron spectra of a (252)Cf source attenuated by water, graphite, liquid nitrogen, and magnesium. Rise-time dPSA has been employed using the common approach for analyzing n +(3)He→(1)H+(3)H ionization events and improved to account for wall-effect and pile-up events, increasing the fidelity of these measurements. Simulations have been performed of the different experimental arrangements and compared with the measurements, demonstrating general agreement between the dPSA-processed fast-neutron spectra and predictions. The fast-neutron resonance features of the attenuation cross sections of the attenuating materials are clearly visible within the resolution limits of the electronics used for the measurements, and the potential applications of high-resolution fast-neutron spectrometry for nuclear nonproliferation and safeguards measurements are discussed. PMID:22728128

  14. Performance parameters of a liquid filled ionization chamber array

    SciTech Connect

    Poppe, B.; Stelljes, T. S.; Looe, H. K.; Chofor, N.; Harder, D.; Willborn, K.

    2013-08-15

    Purpose: In this work, the properties of the two-dimensional liquid filled ionization chamber array Octavius 1000SRS (PTW-Freiburg, Germany) for use in clinical photon-beam dosimetry are investigated.Methods: Measurements were carried out at an Elekta Synergy and Siemens Primus accelerator. For measurements of stability, linearity, and saturation effects of the 1000SRS array a Semiflex 31013 ionization chamber (PTW-Freiburg, Germany) was used as a reference. The effective point of measurement was determined by TPR measurements of the array in comparison with a Roos chamber (type 31004, PTW-Freiburg, Germany). The response of the array with varying field size and depth of measurement was evaluated using a Semiflex 31010 ionization chamber as a reference. Output factor measurements were carried out with a Semiflex 31010 ionization chamber, a diode (type 60012, PTW-Freiburg, Germany), and the detector array under investigation. The dose response function for a single detector of the array was determined by measuring 1 cm wide slit-beam dose profiles and comparing them against diode-measured profiles. Theoretical aspects of the low pass properties and of the sampling frequency of the detector array were evaluated. Dose profiles measured with the array and the diode detector were compared, and an intensity modulated radiation therapy (IMRT) field was verified using the Gamma-Index method and the visualization of line dose profiles.Results: The array showed a short and long term stability better than 0.1% and 0.2%, respectively. Fluctuations in linearity were found to be within ±0.2% for the vendor specified dose range. Saturation effects were found to be similar to those reported in other studies for liquid-filled ionization chambers. The detector's relative response varied with field size and depth of measurement, showing a small energy dependence accounting for maximum signal deviations of ±2.6% from the reference condition for the setup used. The σ-values of the

  15. ^3He Spin Pump

    NASA Astrophysics Data System (ADS)

    Yamaguchi, A.; Ishimoto, H.; Kojima, H.

    2009-03-01

    The superfluid component of ^3He A1 phase is spin-polarized. The process of forcing the superfluid component through a spin filtering structure, in a manner of mechano-magnetic effect, can be used to increase the spin polarization beyond the equilibrium under a given applied magnetic field. We have constructed a test cell in which a glass capillary array acts as the spin (and entropy) filter and an electrostatically actuated diaphragm forces the superfluid flow through it. Preliminary results show that a maximum relative increase of polarization by 50 % could be achieved. The maximum increase in polarization appears to be limited by the critical superfluid flow through the channels in the glass capillary array. The dependence of the observed effects on temperature, pressure and magnetic field will be presented.

  16. NIST Ionization Chamber “A” Sample-Height Corrections

    PubMed Central

    Fitzgerald, Ryan

    2012-01-01

    For over 30 years scientists in the NIST radioactivity group have been using their pressurized ionization chamber “A” (PIC “A”) to make measurements of radioactivity and radioactive half-lives. We now have evidence that some of those reported measurements were incorrect due to slippage of the source positioning ring over time. The temporal change in the holder caused an error in the source-height within the chamber, which was thought to be invariant. This unaccounted-for height change caused a change in the detector response and thus a relative error in measured activity on the order of 10−5 to 10−3 per year, depending on the radionuclide. The drifting detector response affected calibration factors and half-life determinations. After discovering the problem, we carried out historic research and new sensitivity tests. As a result, we have created a quantitative model of the effect and have used that model to estimate corrections to some of the past measurement results from PIC “A”. In this paper we report the details and results of that model. Meanwhile, we have fixed the positioning ring and are recalibrating the detector using primary measurement methods and enhanced quality control measures. PMID:26900515

  17. Ionization collection efficiencies of some ionization chambers in pulsed and continuous radiation beams.

    PubMed

    Holt, J G; Stanton, R E; Sell, R E

    1978-01-01

    The most commonly used method of calibrating high-energy photon or electron beams consists in converting cavity ionization to dose by the application of the appropriate Clambda or CE multipled by the 60Co correction factor. The correct interpretation of calibration data for pulsed photon or electron beams requires a knowledge of the charge collection efficiencies of the ionization chambers used. The results are presented of efficiency measurements for both pulsed and continuous beams made with these chambers: 0.6-cm3 Farmer, 0.5-cm3 Spokas, 3-cm3 Shonka, 1-cm3 PTW, and 1-cm3 Memorial pancake. The dependence of collection efficiency on collection voltage, dose rate, and dose per pulse is demonstrated. These results are shown to agree with Boag's formulas for collection efficiency. Attention is drawn to the fact that several kinds of dosimeters provide only minimal collection voltages for efficient collection of charge at high dose rates, especially in Linac electron beams. It is recommended to check the collection efficiency of chambers which are to be used at high dose rates, and a simple method for this purpose is described. PMID:683147

  18. Polarity correction factor for flattening filter free photon beams in several cylindrical ionization chambers.

    PubMed

    Ogata, Toshiyuki; Uehara, Kazuyuki; Nakayama, Masao; Tsudou, Shinji; Masutani, Takashi; Okayama, Takanobu

    2016-07-01

    In this study, we aimed to compare the polarity correction factor in ionization chambers for flattening filter free (FFF) photon beams and flattening filter (FF) beams. Measurements were performed with both 6 and 10 MV FFF and FF beams. Five commercial ionization chambers were evaluated: PTW TN30013; IBA Dosimetry CC01, CC04, and CC13; and Exradin A12S. Except for the CC01 ionization chamber, the other four chambers showed less than a 0.3 % difference in the polarity effect between the FFF and the FF beams. The CC01 chamber showed a strong field-size-dependence, unlike the other chambers. The polarity effect for all chambers with FFF beams did not change with the dose rate. Except in the case of the CC01 chamber, the difference in the polarity effect between FFF and FF beams was not significant. PMID:26873138

  19. Evaluation of Gas-filled Ionization Chamber Method for Radon Measurement at Two Reference Facilities

    SciTech Connect

    Ishikawa, Tetsuo; Tokonami, Shinji; Kobayashi, Yosuke; Sorimachi, Atsuyuki; Yatabe, Yoshinori; Miyahara, Nobuyuki

    2008-08-07

    For quality assurance, gas-filled ionization chamber method was tested at two reference facilities for radon calibration: EML (USA) and PTB (Germany). Consequently, the radon concentrations estimated by the ionization chamber method were in good agreement with the reference radon concentrations provided by EML as well as PTB.

  20. Investigation of electric field distribution on FAC-IR-300 ionization chamber

    NASA Astrophysics Data System (ADS)

    Mohammadi, S. M.; Tavakoli-Anbaran, H.; Zeinali, H. Z.

    2016-07-01

    One of the important parameters for establishing charge particle equilibrium (CPE) conditions of free-air ionization chamber is an electric field distribution. In this paper, electric field distribution inside the ionization chamber was investigated by finite element method. For this purpose, the effects of adding guard plate and guard strips on the electric field distribution in the ionization chamber were studied. it is necessary to apply a lead box around the ionization chamber body to avoid of scattered radiation effects on the ionization chamber operation, but the lead box changes the electric field distribution. In the following, the effect of lead box on the electric field distribution was studied. Finally, electric field distribution factor (kfield) was calculated by the simulation. The results of the simulation showed that presence of the guard plate and guard strips, and applying a suitable potential to lead box, a convergence of kfield to 1 was achieved.

  1. High spatial resolution dosimetric response maps for radiotherapy ionization chambers measured using kilovoltage synchrotron radiation

    NASA Astrophysics Data System (ADS)

    Butler, D. J.; Stevenson, A. W.; Wright, T. E.; Harty, P. D.; Lehmann, J.; Livingstone, J.; Crosbie, J. C.

    2015-11-01

    Small circular beams of synchrotron radiation (0.1 mm and 0.4 mm in diameter) were used to irradiate ionization chambers of the types commonly used in radiotherapy. By scanning the chamber through the beam and measuring the ionization current, a spatial map of the dosimetric response of the chamber was recorded. The technique is able to distinguish contributions to the large-field ionization current from the chamber walls, central electrode and chamber stem. Scans were recorded for the NE 2571 Farmer chamber, the PTW 30013, IBA FC65-G Farmer-type chambers, the NE 2611A and IBA CC13 thimble chambers, the PTW 31006 and 31014 pinpoint chambers, the PTW Roos and Advanced Markus plane-parallel chambers, and the PTW 23342 thin-window soft x-ray chamber. In all cases, large contributions to the response arise from areas where the incident beam grazes the cavity surfaces. Quantitative as well as qualitative information about the relative chamber response was extracted from the maps, including the relative contribution of the central electrode. Line scans using monochromatic beams show the effect of the photon energy on the chamber response. For Farmer-type chambers, a simple Monte Carlo model was in good agreement with the measured response.

  2. High spatial resolution dosimetric response maps for radiotherapy ionization chambers measured using kilovoltage synchrotron radiation.

    PubMed

    Butler, D J; Stevenson, A W; Wright, T E; Harty, P D; Lehmann, J; Livingstone, J; Crosbie, J C

    2015-11-21

    Small circular beams of synchrotron radiation (0.1 mm and 0.4 mm in diameter) were used to irradiate ionization chambers of the types commonly used in radiotherapy. By scanning the chamber through the beam and measuring the ionization current, a spatial map of the dosimetric response of the chamber was recorded. The technique is able to distinguish contributions to the large-field ionization current from the chamber walls, central electrode and chamber stem. Scans were recorded for the NE 2571 Farmer chamber, the PTW 30013, IBA FC65-G Farmer-type chambers, the NE 2611A and IBA CC13 thimble chambers, the PTW 31006 and 31014 pinpoint chambers, the PTW Roos and Advanced Markus plane-parallel chambers, and the PTW 23342 thin-window soft x-ray chamber. In all cases, large contributions to the response arise from areas where the incident beam grazes the cavity surfaces. Quantitative as well as qualitative information about the relative chamber response was extracted from the maps, including the relative contribution of the central electrode. Line scans using monochromatic beams show the effect of the photon energy on the chamber response. For Farmer-type chambers, a simple Monte Carlo model was in good agreement with the measured response. PMID:26510214

  3. Characterization tests of a homemade ionization chamber in mammography standard radiation beams

    NASA Astrophysics Data System (ADS)

    Silva, J. O.; Nonato, F. B. C.; Caldas, L. V. E.

    2014-02-01

    A mammography homemade ionization chamber was developed to be applied for mammography energy range dosimetry. This chamber has a sensitive volume of 6 cm3 and is made of a Lucite body and graphite coated collecting electrode. Characteristics such as saturation, ion collection efficiency, linearity of chamber response versus air kerma rate and energy dependence were determined. The results obtained with the mammography homemade ionization chamber are within the limits stated in international recommendations. This chamber can be used in quality control programs in the diagnostic radiology area. All measurements were carried out at the Calibration Laboratory of IPEN.

  4. A new mini gas ionization chamber for IBA applications

    NASA Astrophysics Data System (ADS)

    Müller, A. M.; Cassimi, A.; Döbeli, M.; Mallepell, M.; Monnet, I.; Simon, M. J.; Suter, M.; Synal, H.-A.

    2011-12-01

    Novel prototypes of high resolution gas ionization chambers ( GIC) were designed with increased compactness and simplicity of the setup. They have no Frisch-grid and a simple anode wire. Under certain operating conditions these mini detectors have an energy resolution comparable with that of state-of-the-art GICs of much higher complexity. They can be operated both under vacuum and atmospheric pressure. First measurements were made with protons in the energy range of 0.3-1.0 MeV. For protons at 0.3 MeV an energy resolution of about 12 keV was achieved. With a 72 MeV 129Xe beam a relative resolution of 1.4% was obtained. Due to their versatility and reduced size the detectors can easily be applied in the field of ion beam analysis ( IBA) and accelerator mass spectrometry ( AMS) . Since they are almost completely insensitive to radiation damage they are especially suited for use in high fluence applications such as scanning transmission ion microscopy ( STIM). A comparison of the radiation hardness of the mini GIC with a Si PIN diode was therefore performed. The GIC showed no peak shift or change in energy resolution at all after collecting 10 15 protons per cm 2 while the performance of the Si detector clearly started to degrade at 10 12 particles per cm 2.

  5. Coplanar anode implementation in compressed xenon ionization chambers

    NASA Astrophysics Data System (ADS)

    Kiff, Scott Douglas

    This dissertation examines the problem of microphonic degradation of high-pressure xenon ionization chambers' energy spectra. A detector design that utilizes coplanar anodes is proposed to mitigate this problem, and an optimization study finds the best geometry given some constraints on the system. A radial position-sensing method is developed from theory and implemented in experiments, demonstrating usefulness in the areas of hardware diagnostics and energy spectrum enhancement. Detailed simulations quantify the effects of various physical processes on the measured energy spectrum; the processes that degrade the photopeak most severely also show promise for improvement via design and operational changes. Simulations show multiple-site events are undesirable due to resolution degradation. A hydrogen cooling admixture is implemented to improve energy resolution after detailed simulations predict advantageous performance changes. The detector linearity is shown to be quite good over the range tested, 80-1330 keV. The best measured energy resolution is 4.2% FWHM at 662 keV, which is near the range that would be considered competitive with the less-rugged detectors employing Frisch grids.

  6. Simulation of detector signals in n+3 He --> p + t

    NASA Astrophysics Data System (ADS)

    Coppola, Christopher; n3He Collaboration

    2015-10-01

    The parity violating proton directional asymmetry from the capture of polarized neutrons on 3He is being measured with a pulsed neutron beam at the Spallation Neutron Source at Oak Ridge National Laboratory. The target is an ion chamber with 3He at approximately half an atmosphere. Signal wires at different locations in the chamber have different sensitivities to the physics asymmetry, which are determined by the geometry and configuration of the experiment. These geometry factors must be determined by simulation. In addition, a simulation can estimate the statistical precision of the experiment, optimize configuration variables, and assist with error analysis. To achieve the most accurate simulation of the detector signals, a custom simulation was written in C++ using weighted variables and taking advantage of parallel execution. The inputs used to construct the simulation came from measurements of the neutron phase space, ENDF cross sections, and PSTAR ionization data. A cell model was used to combine this physics to produce an accurate simulation of the experimental data. This simulation can be used to calculate accurate and tunable geometry factors, and to produce desired quanities for use in optimization and analysis.

  7. Monte Carlo calculation of energy deposition in ionization chambers for tritium measurements

    NASA Astrophysics Data System (ADS)

    Zhilin, Chen; Shuming, Peng; Dan, Meng; Yuehong, He; Heyi, Wang

    2014-10-01

    Energy deposition in ionization chambers for tritium measurements has been theoretically studied using Monte Carlo code MCNP 5. The influence of many factors, including carrier gas, chamber size, wall materials and gas pressure, has been evaluated in the simulations. It is found that β rays emitted by tritium deposit much more energy into chambers flowing through with argon than with deuterium in them, as much as 2.7 times higher at pressure 100 Pa. As chamber size gets smaller, energy deposition decreases sharply. For an ionization chamber of 1 mL, β rays deposit less than 1% of their energy at pressure 100 Pa and only 84% even if gas pressure is as high as 100 kPa. It also indicates that gold plated ionization chamber results in the highest deposition ratio while aluminum one leads to the lowest. In addition, simulations were validated by comparison with experimental data. Results show that simulations agree well with experimental data.

  8. On the Frisch-Grid signal in ionization chambers

    NASA Astrophysics Data System (ADS)

    Al-Adili, A.; Hambsch, F.-J.; Bencardino, R.; Pomp, S.; Oberstedt, S.; Zeynalov, Sh.

    2012-04-01

    A recent theoretical approach concerning the grid-inefficiency (GI) problem in Twin Frisch-Grid Ionization Chambers was validated experimentally. The experimental verification focused on the induced signal on the anode plate. In this work the investigation was extended by studying the grid signal. The aim was to verify the grid-signal dependency on the grid inefficiency σ. The measurements were made with fission fragments from Cf(sf)252, using two different grids, with 1 and 2 mm wire distances, leading to the GI values: σ=0.031 and σ=0.083, respectively. The theoretical grid signal was confirmed because the detected grid pulse-height distribution was smaller for the larger σ. By applying the additive GI correction approach, the two grid pulse heights were consistent. In the second part of the work, the corrected grid signal was used to deduce emission angles of the fission fragments. It is inconvenient to treat the grid signal by means of conventional analogue electronics, because of its bipolarity. Therefore, the anode and grid signals were summed to create a unipolar, angle-dependent pulse height. Until now the so-called summing method has been the well-established approach to deduce the angle from the grid signal. However, this operation relies strongly on an accurate and stable calibration between the two summed signals. By application of digital-signal processing, the grid signal's bipolarity is no longer an issue. Hence one can bypass the intermediate summation step of the two different pre-amplifier signals, which leads to higher stability. In this work the grid approach was compared to the summing method in three cases: Cf(sf)252, U(n,f)235 and U(n,f)234. By using the grid directly, the angular resolution was found equally good in the first case but gave 7% and 20% improvements, respectively, in the latter cases.

  9. The 3He Supply Problem

    SciTech Connect

    Kouzes, Richard T.

    2009-05-01

    One of the main uses for 3He is in gas proportional counters for neutron detection. Radiation portal monitors deployed for homeland security and non-proliferation use such detectors. Other uses of 3He are for research detectors, commercial instruments, well logging detectors, dilution refrigerators, for targets or cooling in nuclear research, and for basic research in condensed matter physics. The US supply of 3He comes almost entirely from the decay of tritium used in nuclear weapons by the US and Russia. A few other countries contribute a small amount to the world’s 3He supply. Due to the large increase in use of 3He for homeland security, the supply has dwindled, and can no longer meet the demand. This white paper reviews the problems of supply, utilization, and alternatives.

  10. Construction of an ionization chamber for the measurement of dose of low energy x-rays

    SciTech Connect

    Perez, Y. B. Alcantara; Jimenez, F. J. Ramirez

    2008-08-11

    We designed and constructed the prototype of an ionization chamber to measure the dose of an X-ray tube with Molybdenum anode. This X-ray tube is located in the Physics department at CINVESTAV and is used for medical physics purposes in the imaging area. The ionization chamber is designed to measure doses on biological samples exposed to X-rays and will be applied in radiation protection studies.

  11. Pencil beam proton radiography using a multilayer ionization chamber.

    PubMed

    Farace, Paolo; Righetto, Roberto; Meijers, Arturs

    2016-06-01

    A pencil beam proton radiography (PR) method, using a commercial multilayer ionization chamber (MLIC) integrated with a treatment planning system (TPS) was developed. A Giraffe (IBA Dosimetry) MLIC (±0.5 mm accuracy) was used to obtain pencil beam PR by delivering spots uniformly positioned at a 5.0 mm distance in a 9  ×  9 square of spots. PRs of an electron-density (with tissue-equivalent inserts) phantom and a head phantom were acquired. The integral depth dose (IDD) curves of the delivered spots were computed by the TPS in a volume of water simulating the MLIC, and virtually added to the CT at the exit side of the phantoms. For each spot, measured and calculated IDD were overlapped in order to compute a map of range errors. On the head-phantom, the maximum dose from PR acquisition was estimated. Additionally, on the head phantom the impact on the range errors map was estimated in case of a 1 mm position misalignment. In the electron-density phantom, range errors were within 1 mm in the soft-tissue rods, but greater in the dense-rod. In the head-phantom the range errors were  -0.9  ±  2.7 mm on the whole map and within 1 mm in the brain area. On both phantoms greater errors were observed at inhomogeneity interfaces, due to sensitivity to small misalignment, and inaccurate TPS dose computation. The effect of the 1 mm misalignment was clearly visible on the range error map and produced an increased spread of range errors (-1.0  ±  3.8 mm on the whole map). The dose to the patient for such PR acquisitions would be acceptable as the maximum dose to the head phantom was  <2cGyE. By the described 2D method, allowing to discriminate misalignments, range verification can be performed in selected areas to implement an in vivo quality assurance program. PMID:27164479

  12. Pencil beam proton radiography using a multilayer ionization chamber

    NASA Astrophysics Data System (ADS)

    Farace, Paolo; Righetto, Roberto; Meijers, Arturs

    2016-06-01

    A pencil beam proton radiography (PR) method, using a commercial multilayer ionization chamber (MLIC) integrated with a treatment planning system (TPS) was developed. A Giraffe (IBA Dosimetry) MLIC (±0.5 mm accuracy) was used to obtain pencil beam PR by delivering spots uniformly positioned at a 5.0 mm distance in a 9  ×  9 square of spots. PRs of an electron-density (with tissue-equivalent inserts) phantom and a head phantom were acquired. The integral depth dose (IDD) curves of the delivered spots were computed by the TPS in a volume of water simulating the MLIC, and virtually added to the CT at the exit side of the phantoms. For each spot, measured and calculated IDD were overlapped in order to compute a map of range errors. On the head-phantom, the maximum dose from PR acquisition was estimated. Additionally, on the head phantom the impact on the range errors map was estimated in case of a 1 mm position misalignment. In the electron-density phantom, range errors were within 1 mm in the soft-tissue rods, but greater in the dense-rod. In the head-phantom the range errors were  ‑0.9  ±  2.7 mm on the whole map and within 1 mm in the brain area. On both phantoms greater errors were observed at inhomogeneity interfaces, due to sensitivity to small misalignment, and inaccurate TPS dose computation. The effect of the 1 mm misalignment was clearly visible on the range error map and produced an increased spread of range errors (‑1.0  ±  3.8 mm on the whole map). The dose to the patient for such PR acquisitions would be acceptable as the maximum dose to the head phantom was  <2cGyE. By the described 2D method, allowing to discriminate misalignments, range verification can be performed in selected areas to implement an in vivo quality assurance program.

  13. Possibility of using cylindrical ionization chambers for percent depth-dose measurements in clinical electron beams

    SciTech Connect

    Ono, Takeshi; Araki, Fujio; Yoshiyama, Fumiaki

    2011-08-15

    Purpose: This study investigated the possibility of using cylindrical ionization chambers for percent depth-dose (PDD) measurements in high-energy clinical electron beams. Methods: The cavity correction factor, P{sub cav}, for cylindrical chambers with various diameters was calculated as a function of depth from the surface to R{sub 50}, in the energy range of 6-18 MeV electrons with the EGSnrc C ++ -based user-code CAVITY. The results were compared with those for IBA NACP-02 and PTW Roos parallel-plate ionization chambers. The effective point of measurement (EPOM) for the cylindrical chamber and the parallel-plate chamber was positioned according to the IAEA TRS-398 code of practice. The overall correction factor, P{sub Q}, and the percent depth-ionization (PDI) curve for a PTW30013 Farmer-type chamber were also compared with those of NACP-02 and Roos chambers. Results: The P{sub cav} values at depths between the surface and R{sub 50} for cylindrical chambers were all lower than those with parallel-plate chambers. However, the variation in depth for cylindrical chambers equal to or less than 4 mm in diameter was equivalent to or smaller than that for parallel-plate chambers. The P{sub Q} values for the PTW30013 chamber mainly depended on P{sub cav}, and for parallel-plate chambers depended on the wall correction factor, P{sub wall}, rather than P{sub cav}. P{sub Q} at depths from the surface to R{sub 50} for the PTW30013 chamber was consequently a lower value than that with parallel-plate chambers. However, the variation in depth was equivalent to that of parallel-plate chambers at electron energies equal to or greater than 9 MeV. The shift to match calculated PDI curves for the PTW30013 chamber and water (perturbation free) varied from 0.65 to 0 mm between 6 and 18 MeV beams. Similarly, the shifts for NACP-02 and Roos chambers were 0.5-0.6 mm and 0.2-0.3 mm, respectively, and were nearly independent of electron energy. Conclusions: Calculated PDI curves for PTW

  14. Ionization statistics and diffusion: analytical estimate of their contribution to spatial resolution of drift chambers

    SciTech Connect

    Tarnopolsky, G.J.

    1983-01-01

    The spatial resolution of a drift chamber often is the foremost design parameter. The calculation described here - a design tool - permits us to estimate the contributions of ionization statistics and diffusion to the spatial resolution when actually sampling the drift pulse waveform. Useful formulae are derived for the cylindrical and jet-chamber cell geometries.

  15. IEC-^3He Breeder for D-^3He Satellite Systems.

    NASA Astrophysics Data System (ADS)

    Chacon, L.; Miley, G. H.

    1996-11-01

    D-^3He fusion minimizes neutrons and maximizes charged fusion products, enabling increased energy recovery efficiency by direct conversion. However, scarce ^3He terrestrial resources have deterred R&D on this alternative. Here, we explore ^3He production through Inertial Electrostatic Confinement^1 (IEC) D-breeders, which supply ^3He to FRC D-^3He satellite reactors.^2 Favorable features for the IEC breeder include simplicity, low cost, easy extraction of fusion products, and compatibility with direct conversion. The breeder-satellite system energy balance is analyzed taking the net energy gain of the overall system, Q_N, as the figure of merit. Breeding is applicable for systems where the satellite Q-value, Q_S, > the breeder Q-value, Q_B. For improved performance, i.e., for high Q_N, QS >= QB >> 1 is needed; however, lower QB values (typical of the IEC) are permissible and still offer sufficient Q_N. An economic study determined breeding produces ^3He at a cost comparable to lunar ^3He, already shown to lead to competitive power.^3 The cost of electricity (COE) for the breeder-satellite complex was compared with the ARTEMIS COE,^4 using lunar ^3He fuel: assuming one satellite (1000 MWe)/breeder (170 MWe), the ratio of the breeding system COE to the lunar mining base COE is ~ 1.2. However, economic breeding is driven by large IEC breeder powers, i.e., increased ^3He breeding rates. Thus, the COE ratio approaches unity with two or three satellites/breeder, requiring increased breeder size and power (340 MWe for 2 satellites, 510 MWe for 3 satellites). Such systems potentially provide a ``bridge'' to a future lunar ^3He economy. 1. G.H. Miley et al., Dense Z-pinches, AIP Conf. 299, AIP Press, 675-689 (1994). 2. G.H. Miley, Nucl. Instrum. Methods, A271, 197-202 (1988). 3. L.J. Wittenberg et al., Fusion Technol., 10, 167-178 (1986). 4. H. Momota et al., Fusion Technol., 21, 2307-2323 (1992).

  16. Beam tests of ionization chambers for the NuMI neutrino beam

    SciTech Connect

    Robert M. Zwaska et al.

    2003-09-25

    We have conducted tests at the Fermilab Booster of ionization chambers to be used as monitors of the NuMI neutrino beamline. The chambers were exposed to proton fluxes of up to 10{sup 12} particles/cm{sup 2}/1.56 {micro}s. We studied space charge effects which can reduce signal collection from the chambers at large charged particle beam intensities.

  17. Investigation of the applicability of a special parallel-plate ionization chamber for x-ray beam dosimetry

    NASA Astrophysics Data System (ADS)

    Perini, Ana P.; P. Neves, Lucio; E. Caldas, Linda V.

    2014-02-01

    Diagnostic x-rays are the greatest source of exposition to ionizing radiation of the population worldwide. In order to obtain accurate and lower-cost dosimeters for quality control assurance of medical x-ray facilities, a special ionization chamber was designed at the Calibration Laboratory of the IPEN, for dosimetry in diagnostic radiology beams. For the chamber characterization some tests were undertaken. Monte Carlo simulations were proposed to evaluate the distribution of the deposited energy in the sensitive volume of the ionization chamber and the collecting electrode effect on the chamber response. According to the obtained results, this special ionization chamber presents potential use for dosimetry of conventional diagnostic radiology beams.

  18. Relaxation time of 3He

    NASA Astrophysics Data System (ADS)

    Gao, Hayian

    2004-10-01

    The next generation of searches for the neutron electric dipole moment using ultra cold neutrons will use polarized ^3He as a co-magnetometer. The first such experiment has been proposed, with a goal of improving the current limit on the neutron EDM by two orders of magnitude. This experiment requires a systematic study of the properties of polarized ^3He at cryogenic temperatures under actual experimental conditions. These experimental conditions include polarized ^3He mixed in a bath of superfluid ^4He in low magnetic field and held in an acrylic cell which is coated with deuterated TetraphenylButadiene . Parts of these systematic studies will be done at Duke University using a newly built, novel refillable double cell ^3 He polarizer based on spin exchange optical pumping with Rubidium vapor. The polarimetry for this apparatus is done with a NMR polarimeter using the adiabatic fast passage method. An alternate polarimeter using free induction decay method is also being built. This apparatus is being used to study the relaxation time and other critical properties of polarized ^3He at temperatures ranging from 2.3 - 4.2 K, under simulated experimental conditions. We will present details about this novel polarizer and show preliminary results of our measurements.

  19. Absolute dosimetry on a dynamically scanned sample for synchrotron radiotherapy using graphite calorimetry and ionization chambers

    NASA Astrophysics Data System (ADS)

    Lye, J. E.; Harty, P. D.; Butler, D. J.; Crosbie, J. C.; Livingstone, J.; Poole, C. M.; Ramanathan, G.; Wright, T.; Stevenson, A. W.

    2016-06-01

    The absolute dose delivered to a dynamically scanned sample in the Imaging and Medical Beamline (IMBL) on the Australian Synchrotron was measured with a graphite calorimeter anticipated to be established as a primary standard for synchrotron dosimetry. The calorimetry was compared to measurements using a free-air chamber (FAC), a PTW 31 014 Pinpoint ionization chamber, and a PTW 34 001 Roos ionization chamber. The IMBL beam height is limited to approximately 2 mm. To produce clinically useful beams of a few centimetres the beam must be scanned in the vertical direction. In practice it is the patient/detector that is scanned and the scanning velocity defines the dose that is delivered. The calorimeter, FAC, and Roos chamber measure the dose area product which is then converted to central axis dose with the scanned beam area derived from Monte Carlo (MC) simulations and film measurements. The Pinpoint chamber measures the central axis dose directly and does not require beam area measurements. The calorimeter and FAC measure dose from first principles. The calorimetry requires conversion of the measured absorbed dose to graphite to absorbed dose to water using MC calculations with the EGSnrc code. Air kerma measurements from the free air chamber were converted to absorbed dose to water using the AAPM TG-61 protocol. The two ionization chambers are secondary standards requiring calibration with kilovoltage x-ray tubes. The Roos and Pinpoint chambers were calibrated against the Australian primary standard for air kerma at the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA). Agreement of order 2% or better was obtained between the calorimetry and ionization chambers. The FAC measured a dose 3–5% higher than the calorimetry, within the stated uncertainties.

  20. Absolute dosimetry on a dynamically scanned sample for synchrotron radiotherapy using graphite calorimetry and ionization chambers.

    PubMed

    Lye, J E; Harty, P D; Butler, D J; Crosbie, J C; Livingstone, J; Poole, C M; Ramanathan, G; Wright, T; Stevenson, A W

    2016-06-01

    The absolute dose delivered to a dynamically scanned sample in the Imaging and Medical Beamline (IMBL) on the Australian Synchrotron was measured with a graphite calorimeter anticipated to be established as a primary standard for synchrotron dosimetry. The calorimetry was compared to measurements using a free-air chamber (FAC), a PTW 31 014 Pinpoint ionization chamber, and a PTW 34 001 Roos ionization chamber. The IMBL beam height is limited to approximately 2 mm. To produce clinically useful beams of a few centimetres the beam must be scanned in the vertical direction. In practice it is the patient/detector that is scanned and the scanning velocity defines the dose that is delivered. The calorimeter, FAC, and Roos chamber measure the dose area product which is then converted to central axis dose with the scanned beam area derived from Monte Carlo (MC) simulations and film measurements. The Pinpoint chamber measures the central axis dose directly and does not require beam area measurements. The calorimeter and FAC measure dose from first principles. The calorimetry requires conversion of the measured absorbed dose to graphite to absorbed dose to water using MC calculations with the EGSnrc code. Air kerma measurements from the free air chamber were converted to absorbed dose to water using the AAPM TG-61 protocol. The two ionization chambers are secondary standards requiring calibration with kilovoltage x-ray tubes. The Roos and Pinpoint chambers were calibrated against the Australian primary standard for air kerma at the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA). Agreement of order 2% or better was obtained between the calorimetry and ionization chambers. The FAC measured a dose 3-5% higher than the calorimetry, within the stated uncertainties. PMID:27192396

  1. Theoretical study of energy deposition in ionization chambers for tritium measurements

    NASA Astrophysics Data System (ADS)

    Chen, Zhilin; Peng, Shuming; Meng, Dan; He, Yuehong; Wang, Heyi

    2013-10-01

    Energy deposition in ionization chambers has been theoretically studied for tritium measurements in gaseous form. A one-dimension model is introduced to establish the quantitative relationship between energy deposition rate and many factors, including carrier gas, gas pressure, wall material, chamber size, and gas temperature. Energy deposition rate has been calculated at pressure varying from 5 kPa to 500 kPa based on some approximations. It is found that energy deposition rate varies greatly for different parameters, especially at low gas pressure. For the same chamber, energy deposition rate in argon is much higher than in deuterium, as much as 70.7% higher at 5 kPa. Gold plated chamber gives highest energy deposition rate in the calculations while aluminum chamber results in the lowest. As chamber size gets smaller, β ray emitted by tritium will deposit less energy in the sensitive region of the chamber. For chambers flowing through with the same gas, energy deposition rate in a 10 L chamber is 23.9% higher than in a 0.05 L chamber at 5 kPa. Gas temperature also places slight influence on energy deposition rate, and 373 K will lead to 6.7% lower deposition rate than 233 K at 5 kPa. In addition, experiments have been performed to obtain energy deposition rate in a gold plated chamber, which show good accordance with theoretical calculations.

  2. Theoretical study of energy deposition in ionization chambers for tritium measurements

    SciTech Connect

    Chen, Zhilin; Peng, Shuming; Meng, Dan; He, Yuehong; Wang, Heyi

    2013-10-15

    Energy deposition in ionization chambers has been theoretically studied for tritium measurements in gaseous form. A one-dimension model is introduced to establish the quantitative relationship between energy deposition rate and many factors, including carrier gas, gas pressure, wall material, chamber size, and gas temperature. Energy deposition rate has been calculated at pressure varying from 5 kPa to 500 kPa based on some approximations. It is found that energy deposition rate varies greatly for different parameters, especially at low gas pressure. For the same chamber, energy deposition rate in argon is much higher than in deuterium, as much as 70.7% higher at 5 kPa. Gold plated chamber gives highest energy deposition rate in the calculations while aluminum chamber results in the lowest. As chamber size gets smaller, β ray emitted by tritium will deposit less energy in the sensitive region of the chamber. For chambers flowing through with the same gas, energy deposition rate in a 10 L chamber is 23.9% higher than in a 0.05 L chamber at 5 kPa. Gas temperature also places slight influence on energy deposition rate, and 373 K will lead to 6.7% lower deposition rate than 233 K at 5 kPa. In addition, experiments have been performed to obtain energy deposition rate in a gold plated chamber, which show good accordance with theoretical calculations.

  3. Dosimetric application of a special pencil ionization chamber in radiotherapy X-ray beams

    NASA Astrophysics Data System (ADS)

    Neves, Lucio P.; Perini, Ana P.; Fernández-Varea, José M.; Cassola, Vagner F.; Kramer, Richard; Khoury, Helen J.; Caldas, Linda V. E.

    2014-02-01

    The aim of this work was to study the performance of a pencil ionization chamber with a sensitive volume of only 1.06 cm3 and a length of 3.0 cm, developed at the Calibration Laboratory of the IPEN, in very low-energy radiotherapy X-ray beams. These beams are still used for certain skin cancer treatments due to their rapid attenuation in tissue. The dosimeter performance was evaluated in some tests proposed by the IEC 60731 standard: short- and long-term stability and linearity of response. For a complete analysis of the dosimeter response, the EGSnrc Monte Carlo simulation was utilized to investigate the influence of its different parts on the ionization chamber response. All results of the tests were in accordance with the recommended limits, and this work shows that it is possible to extend the application of this pencil-type ionization chamber developed at the LCI.

  4. Virtual Frisch-grid ionization chambers filled with high-pressure Xe

    NASA Astrophysics Data System (ADS)

    Bolotnikov, Aleksey E.; Austin, Robert; Bolozdynya, Alexander; Richards, John D.

    2004-10-01

    New approaches to the design of high-pressure Xe (HPXe) ionization chambers are described. HPXe ionization chambers represent a well-known technique for detecting gamma rays in the energy range between 50 keV and 3 MeV. Since the HPXe detector is an electron-only carrier device, its commonly accepted design includes a Frisch-grid-a metal mesh employed for the electrostatic shielding from the immobile positive ions. The grid is a key element of the device"s design which provides good energy resolution of the detector, typically 2-3% FWHM at 662 keV. However, the grid makes the design more complex and less rugged, especially for field applications. Recently, we developed several designs of HPXe ionization chambers without shielding grids. The results obtained from the testing of these devices are presented here.

  5. Performance of three pencil-type ionization chambers (10 cm) in computed tomography standard beams

    NASA Astrophysics Data System (ADS)

    de Castro, Maysa C.; Xavier, Marcos; Caldas, Linda V. E.

    2016-07-01

    The use of computed tomography (CT) has increased over the years, thus generating a concern about the doses received by patients undergoing this procedure. Therefore, it is necessary to perform routinely beam dosimetry with the use of a pencil-type ionization chamber. This detector is the most utilized in the procedures of quality control tests on this kind of equipment. The objective of this work was to perform some characterization tests in standard CT beams, as the saturation curve, polarity effect, ion collection efficiency and linearity of response, using three ionization chambers, one commercial and two developed at the IPEN.

  6. Characterization of a free air ionization chamber for low energy X-rays

    NASA Astrophysics Data System (ADS)

    Silva, N. F.; Xavier, M.; Vivolo, V.; Caldas, L. V. E.

    2016-07-01

    Free air ionization chambers are used by most primary metrology laboratories as primary standards of the quantities air kerma and exposure in X-ray beams. The free air ionization chamber for low energies of the Calibration Laboratory (LCI) of IPEN showed in a characterization test a problem in the set responsible for the variation of its sensitive volume. After a modification in the support of the micrometers used for the movement of the internal cylinder and the establishment of a new alignment system protocol, the tests were redone. The objective of this work was to present the results obtained in the new condition.

  7. Response and Monte Carlo evaluation of a reference ionization chamber for radioprotection level at calibration laboratories

    NASA Astrophysics Data System (ADS)

    Neves, Lucio P.; Vivolo, Vitor; Perini, Ana P.; Caldas, Linda V. E.

    2015-07-01

    A special parallel plate ionization chamber, inserted in a slab phantom for the personal dose equivalent Hp(10) determination, was developed and characterized in this work. This ionization chamber has collecting electrodes and window made of graphite, and the walls and phantom made of PMMA. The tests comprise experimental evaluation following international standards and Monte Carlo simulations, employing the PENELOPE code to evaluate the design of this new dosimeter. The experimental tests were conducted employing the radioprotection level quality N-60 established at the IPEN, and all results were within the recommended standards.

  8. A multiple sampling time projection ionization chamber for nuclear fragment tracking and charge measurement

    NASA Astrophysics Data System (ADS)

    Bauer, G.; Bieser, F.; Brady, F. P.; Chance, J. C.; Christie, W. F.; Gilkes, M.; Lindenstruth, V.; Lynen, U.; Müller, Walter F. J.; Romero, J. L.; Sann, H.; Tull, C. E.; Warren, P.

    1997-02-01

    A detector has been developed for the tracking and charge measurement of the projectile fragment nuclei produced in relativistic nuclear collisions. This device, MUSIC II, is a second generation Multiple Sampling Ionization Chamber (MUSIC), and employs the principles of ionization and time projection chambers. It provides unique charge determination for charges Z≥6, and excellent track position measurement. MUSIC II has been used most recently with the EOS (Equation of State) TPC and other EOS Collaboration detectors. Earlier it was used with other systems in experiments at the Heavy Ion Superconducting Spectrometer (HISS) facility at Lawrence Berkeley Laboratory and the ALADIN spectrometer at GSI.

  9. Pulse mode readout techniques for use with non-gridded industrial ionization chambers

    SciTech Connect

    Popov, Vladimir E.; Degtiarenko, Pavel V.

    2011-10-01

    Highly sensitive readout technique for precision long-term radiation measurements has been developed and tested in the Radiation Control Department at Jefferson Lab. The new electronics design is used to retrieve ionization data in a pulse mode. The dedicated data acquisition system works with M=Audio Audiophile 192 High-Definition 24-bit/192 kHz audio cards, taking data in continuous waveform recording mode. The on-line data processing algorithms extract signals of the ionization events from the data flow and measure the ionization value for each event. Two different ion chambers are evaluated. The first is a Reuter-Stokes Argon-filled (at 25 atm) High Pressure Ionization Chamber (HPIC), commonly used as a detector part in many GE Reuter-Stokes instruments of the RSS series. The second is a VacuTec Model 70181, 5 atm Xenon-filled ionization chamber. Results for both chambers indicate that the techniques allow using industrial ICs for high sensitivity and precision long-term radiation measurements, while at the same time providing information about spectral characteristics of the radiation fields.

  10. Assessment of small volume ionization chambers as reference dosimeters in high-energy photon beams

    NASA Astrophysics Data System (ADS)

    Le Roy, M.; de Carlan, L.; Delaunay, F.; Donois, M.; Fournier, P.; Ostrowsky, A.; Vouillaume, A.; Bordy, J. M.

    2011-09-01

    LNE-LNHB is involved in a European project aiming at establishing absorbed dose-to-water standards for photon-radiation fields down to 2 × 2 cm2. This requires the calibration of reference ionization chambers of small volume. Twenty-four ionization chambers of eight different types with volume ranging from 0.007 to 0.057 cm3 were tested in a 60Co beam. For each chamber, two major characteristics were investigated: (1) the stability of the measured current as a function of the irradiation time under continuous irradiation. At LNE-LNHB, the variation of the current should be less than ±0.1% in comparison with its first value (over a 16 h irradiation time); (2) the variation of the ionization current with the applied polarizing voltage and polarity. Leakage currents were also measured. Results show that (1) every tested PTW (31015, 31016 and 31014) and Exradin A1SL chambers demonstrate a satisfying stability under irradiation. Other types of chambers have a stability complying with the stability criterion for some or none of them. (2) IBA CC01, IBA CC04 and Exradin A1SL show a proper response as a function of applied voltage for both polarities. PTW, Exradin A14SL and Exradin A16 do not. Only three types of chambers were deemed suitable as reference chambers according to LNE-LNHB requirements and specifications from McEwen (2010 Med. Phys. 37 2179-93): Exradin A1SL chambers (3/3), IBA CC04 (2/3) and IBA CC01 (1/3). The Exradin A1SL type with an applied polarizing voltage of 150 V was chosen as an LNE-LNHB reference chamber type in 2 × 2 cm2 radiation fields.

  11. Breast in vivo dosimetry by a portal ionization chamber

    SciTech Connect

    Grimaldi, Luca; D'Onofrio, Guido; Cilla, Savino; Fidanzio, Andrea; Stimato, Gerardina; Azario, Luigi; Deodato, Francesco; Macchia, Gabriella; Morganti, Alessio; Piermattei, Angelo

    2007-03-15

    This work reports a practical method for the determination of the in vivo breast middle dose value, D{sub m}, on the beam central axis, using a signal S{sub t}, obtained by a small thimble ion chamber positioned at the center of the electronic portal imaging device, and irradiated by the x-ray beam transmitted through the patient. The use of a stable ion chamber reduces many of the disadvantages associated with the use of diodes as their periodic recalibration and positioning is time consuming. The method makes use of a set of correlation functions obtained by the ratios S{sub t}/D{sub m}, determined by irradiating cylindrical water phantoms with different diameters. The method proposed here is based on the determination of the water-equivalent thickness of the patient, along the beam central axis, by the treatment planning system that makes use of the electron densities obtained by a computed tomography scanner. The method has been applied for the breast in vivo dosimetry of ten patients treated with a manual intensity modulation with four asymmetric beams. In particular, two tangential rectangular fields were first delivered, thereafter a fraction of the dose (typically less than 10%) was delivered with two multi leaf-shaped beams which included only the mammarian tissue. Only the two rectangular fields were tested and for every checked field five measurements were carried out. Applying a continuous quality assurance program based on the tests of patient setup, machine settings and dose planning, the proposed method is able to verify agreements between the computed dose D{sub m,TPS} and the in vivo dose value D{sub m}, within 4%.

  12. Source geometry factors for HDR 192Ir brachytherapy secondary standard well-type ionization chamber calibrations

    NASA Astrophysics Data System (ADS)

    Shipley, D. R.; Sander, T.; Nutbrown, R. F.

    2015-03-01

    Well-type ionization chambers are used for measuring the source strength of radioactive brachytherapy sources before clinical use. Initially, the well chambers are calibrated against a suitable national standard. For high dose rate (HDR) 192Ir, this calibration is usually a two-step process. Firstly, the calibration source is traceably calibrated against an air kerma primary standard in terms of either reference air kerma rate or air kerma strength. The calibrated 192Ir source is then used to calibrate the secondary standard well-type ionization chamber. Calibration laboratories are usually only equipped with one type of HDR 192Ir source. If the clinical source type is different from that used for the calibration of the well chamber at the standards laboratory, a source geometry factor, ksg, is required to correct the calibration coefficient for any change of the well chamber response due to geometric differences between the sources. In this work we present source geometry factors for six different HDR 192Ir brachytherapy sources which have been determined using Monte Carlo techniques for a specific ionization chamber, the Standard Imaging HDR 1000 Plus well chamber with a type 70010 HDR iridium source holder. The calculated correction factors were normalized to the old and new type of calibration source used at the National Physical Laboratory. With the old Nucletron microSelectron-v1 (classic) HDR 192Ir calibration source, ksg was found to be in the range 0.983 to 0.999 and with the new Isodose Control HDR 192Ir Flexisource ksg was found to be in the range 0.987 to 1.004 with a relative uncertainty of 0.4% (k = 2). Source geometry factors for different combinations of calibration sources, clinical sources, well chambers and associated source holders, can be calculated with the formalism discussed in this paper.

  13. Stability of A-150 plastic ionization chamber response over a ~30 year period

    SciTech Connect

    Kroc, Thomas K.; Lennox, Arlene J.; /Fermilab

    2007-08-01

    At the NIU Institute for Neutron Therapy at Fermilab, the clinical tissue-equivalent ionization chamber response is measured every treatment day using a cesium source that was configured to match readings obtained at the National Bureau of Standards. Daily measurements are performed in air using the air-to-tissue dose conversion factors given in AAPM Report no. 7. The measured exposure calibration factors have been tabulated and graphed as a function of time from 1978 to present. For A-150 plastic ionization chambers, these factors exhibit a sinusoidal variation with a period of approximately one year and amplitude of {+-} 1%. This variation, attributable to the hygroscopic nature of A-150 plastic, is correlated with the relative humidity of the facility, and is greater than the humidity corrections for gas described in the literature. Our data suggest that chamber calibration should be performed at least weekly to accommodate these variations.

  14. High-resolution ion pulse ionization chamber with air filling for the 222Rn decays detection

    NASA Astrophysics Data System (ADS)

    Gavrilyuk, Yu. M.; Gangapshev, A. M.; Gezhaev, A. M.; Etezov, R. A.; Kazalov, V. V.; Kuzminov, V. V.; Panasenko, S. I.; Ratkevich, S. S.; Tekueva, D. A.; Yakimenko, S. P.

    2015-11-01

    The construction and characteristics of the cylindrical ion pulse ionization chamber (CIPIC) with a working volume of 3.2 L are described. The chamber is intended to register α-particles from the 222Rn and its daughter's decays in the filled air sample. The detector is less sensitive to electromagnetic pick-ups and mechanical noises. The digital pulse processing method is proposed to improve the energy resolution of the ion pulse ionization chamber. An energy resolution of 1.6% has been achieved for the 5.49 MeV α-line. The dependence of the energy resolution on high voltage and working media pressure has been investigated and the results are presented.

  15. On 3He bolometer systems

    NASA Technical Reports Server (NTRS)

    Houck, J. R.

    1983-01-01

    A 3He cryostat which was constructed to cool a germanium bolometer for use as an infrared detector at submillimeter wavelength is discussed. The system had better sensitivity than any other existing system for these wavelengths; the system could be improved if better optical coupling could be achieved between the bolometer and the incoming photon stream. Considerable effort was expended to improve this coupling. Even the best results however, fell short of an ideal system by a factor of nearly 5 in coupling efficiency.

  16. A multipurpose 3He refrigerator

    NASA Astrophysics Data System (ADS)

    Pizzo, L.; Dall'Oglio, G.; Martinis, L.; Sabbatini, L.

    2006-10-01

    We introduce a mini 3He refrigerator, operating at ˜300 mK starting from 4.2 K without pumping on the main 4He bath. The innovative idea is that the present one is suitable for a very fast operation; for its use, it is sufficient a storage 4He Dewar. In this way we drastically reduce the time required to cool it down, because there is no need for a classic cryostat. This prototype is particularly aimed for all those operations in which it is necessary to test a large number of samples that do not require long duration measurements at low temperature.

  17. Determination of ion recombination correction factors for a liquid ionization chamber in megavoltage photon beams

    NASA Astrophysics Data System (ADS)

    Choi, Sang Hyoun; Kim, Kum-Bae; Ji, Young Hoon; Kim, Chan Hyeong; Kim, Seonghoon; Huh, Hyun Do

    2015-05-01

    The aim of this study is to determine the ion recombination correction factor for a liquid ionization chamber in a high energy photon beam by using our experimental method. The ion recombination correction factors were determined by using our experimental method and were compared with theoretical and experimental methods proposed by using the theoretical method (Greening, Johansson) and the two-dose rate method in a cobalt beam and a high energy photon beam. In order to apply the liquid ionization chamber in a reference and small field dosimetry, we acquired the absorbed dose to water correction coefficient, the beam quality correction factor, and the influence quantities for the microLion chamber according to the TRS-398 protocol and applied the results to a high energy photon beam used in clinical fields. As a result, our experimental method for ion recombination in a cobalt beam agreed with the results from the heoretical method (Greening theory) better than it did with the results from the two-dose rate method. For high energy photon beams, the two-dose rate and our experimental methods were in good agreement, less than 2% deviation, while the theoretical general collection efficiency (Johansson et al.) deviated greatly from the experimental values. When we applied the factors for the absorbed dose to water measurement, the absorbed dose to water for the microLion chamber was in good agreement, within 1%, compared with the values for the PTW 30013 chamber in 6 and 10 MV Clinac iX and 6 and 15 MV Oncor impression. With these results, not only can the microLion ionization chamber be used to measure the absorbed dose to water in a reference condition, it can also be used to a the chamber for small, non-standard field dosimetry.

  18. Towards reference dosimetry for the MR-linac: magnetic field correction of the ionization chamber reading

    NASA Astrophysics Data System (ADS)

    Smit, K.; van Asselen, B.; Kok, J. G. M.; Aalbers, A. H. L.; Lagendijk, J. J. W.; Raaymakers, B. W.

    2013-09-01

    In the UMC Utrecht a prototype MR-linac has been installed. The system consists of a 6 MV Elekta (Crawley, UK) linear accelerator and a 1.5 T Philips (Best, The Netherlands) Achieva MRI system. This paper investigates the feasibility to correct the ionization chamber reading for the magnetic field within the dosimetry calibration method described by Almond et al (1999 Med. Phys. 26 1847-70). Firstly, the feasibility of using an ionization chamber in an MR-linac was assessed by investigating possible influences of the magnetic field on NE2571 Farmer-type ionization chamber characteristics: linearity, repeatability, orientation in the magnetic field; and AAPM TG51 correction factor for voltage polarity and ion recombination. We found that these AAPM correction factors for the NE2571 chamber were not influenced by the magnetic field. Secondly, the influence of the permanent 1.5 T magnetic field on the NE2571 chamber reading was quantified. The reading is influenced by the magnetic field; therefore, a correction factor has been added. For the standardized setup used in this paper, the NE2571 chamber reading increases by 4.9% (± 0.2%) due to the transverse 1.5 T magnetic field. Dosimetry measurements in an MR-linac are feasible, if a setup-specific magnetic field correction factor (P1.5 T) for the charge reading is introduced. For the setup investigated in this paper, the P1.5 T has a value of 0.953.

  19. Towards reference dosimetry for the MR-linac: magnetic field correction of the ionization chamber reading.

    PubMed

    Smit, K; van Asselen, B; Kok, J G M; Aalbers, A H L; Lagendijk, J J W; Raaymakers, B W

    2013-09-01

    In the UMC Utrecht a prototype MR-linac has been installed. The system consists of a 6 MV Elekta (Crawley, UK) linear accelerator and a 1.5 T Philips (Best, The Netherlands) Achieva MRI system. This paper investigates the feasibility to correct the ionization chamber reading for the magnetic field within the dosimetry calibration method described by Almond et al (1999 Med. Phys. 26 1847-70). Firstly, the feasibility of using an ionization chamber in an MR-linac was assessed by investigating possible influences of the magnetic field on NE2571 Farmer-type ionization chamber characteristics: linearity, repeatability, orientation in the magnetic field; and AAPM TG51 correction factor for voltage polarity and ion recombination. We found that these AAPM correction factors for the NE2571 chamber were not influenced by the magnetic field. Secondly, the influence of the permanent 1.5 T magnetic field on the NE2571 chamber reading was quantified. The reading is influenced by the magnetic field; therefore, a correction factor has been added. For the standardized setup used in this paper, the NE2571 chamber reading increases by 4.9% (± 0.2%) due to the transverse 1.5 T magnetic field. Dosimetry measurements in an MR-linac are feasible, if a setup-specific magnetic field correction factor (P1.5 T) for the charge reading is introduced. For the setup investigated in this paper, the P1.5 T has a value of 0.953. PMID:23938362

  20. Improving the accuracy of ionization chamber dosimetry in small megavoltage x-ray fields

    NASA Astrophysics Data System (ADS)

    McNiven, Andrea L.

    The dosimetry of small x-ray fields is difficult, but important, in many radiation therapy delivery methods. The accuracy of ion chambers for small field applications, however, is limited due to the relatively large size of the chamber with respect to the field size, leading to partial volume effects, lateral electronic disequilibrium and calibration difficulties. The goal of this dissertation was to investigate the use of ionization chambers for the purpose of dosimetry in small megavoltage photon beams with the aim of improving clinical dose measurements in stereotactic radiotherapy and helical tomotherapy. A new method for the direct determination of the sensitive volume of small-volume ion chambers using micro computed tomography (muCT) was investigated using four nominally identical small-volume (0.56 cm3) cylindrical ion chambers. Agreement between their measured relative volume and ionization measurements (within 2%) demonstrated the feasibility of volume determination through muCT. Cavity-gas calibration coefficients were also determined, demonstrating the promise for accurate ion chamber calibration based partially on muCT. The accuracy of relative dose factor measurements in 6MV stereotactic x-ray fields (5 to 40mm diameter) was investigated using a set of prototype plane-parallel ionization chambers (diameters of 2, 4, 10 and 20mm). Chamber and field size specific correction factors ( CSFQ ), that account for perturbation of the secondary electron fluence, were calculated using Monte Carlo simulation methods (BEAM/EGSnrc simulations). These correction factors (e.g. CSFQ = 1.76 (2mm chamber, 5mm field) allow for accurate relative dose factor (RDF) measurement when applied to ionization readings, under conditions of electronic disequilibrium. With respect to the dosimetry of helical tomotherapy, a novel application of the ion chambers was developed to characterize the fan beam size and effective dose rate. Characterization was based on an adaptation of the

  1. Hard Photodisintegration of 3He

    NASA Astrophysics Data System (ADS)

    Granados, Carlos

    2011-02-01

    Large angle photodisintegration of two nucleons from the 3He nucleus is studied within the framework of the hard rescattering model (HRM). In the HRM the incoming photon is absorbed by one nucleon's valence quark that then undergoes a hard rescattering reaction with a valence quark from the second nucleon producing two nucleons emerging at large transverse momentum . Parameter free cross sections for pp and pn break up channels are calculated through the input of experimental cross sections on pp and pn elastic scattering. The calculated cross section for pp breakup and its predicted energy dependency are in good agreement with recent experimental data. Predictions on spectator momentum distributions and helicity transfer are also presented.

  2. A liquid xenon ionization chamber in an all-fluoropolymer vessel

    NASA Astrophysics Data System (ADS)

    LePort, F.; Pocar, A.; Bartoszek, L.; DeVoe, R.; Fierlinger, P.; Flatt, B.; Gratta, G.; Green, M.; Koffas, T.; Montero Díez, M.; Neilson, R.; O'Sullivan, K.; Waldman, S.; Wodin, J.; Woisard, D.; Baussan, E.; Breidenbach, M.; Conley, R.; Fairbank, W.; Farine, J.; Hall, C.; Hall, K.; Hallman, D.; Hargrove, C.; Hodgson, J.; Jeng, S.; Leonard, D. S.; Mackay, D.; Martin, Y.; Odian, A.; Ounalli, L.; Piepke, A.; Prescott, C. Y.; Rowson, P. C.; Skarpaas, K.; Schenker, D.; Sinclair, D.; Stekhanov, V.; Strickland, V.; Virtue, C.; Vuilleumier, J.-L.; Vuilleumier, J.-M.; Wamba, K.; Weber, P.

    2007-08-01

    A novel technique has been developed to build vessels for liquid xenon ionization detectors entirely out of an ultra-clean fluoropolymer. One such detector was operated inside a welded, He leak tight, all-fluoropolymer chamber. The measured energy resolution for 570 keV gamma rays is σ/E=5.1% at a drift field of 1.5 kV/cm, in line with the best values obtained for ionization only detectors run in LXe using conventional, metal vessels.

  3. Total diesel exhaust particulate length measurements using a modified household smoke alarm ionization chamber.

    PubMed

    Vojtisek-Lom, Michal

    2011-02-01

    To evaluate the effectiveness of various means to combat the negative health effects of ultrafine particles emitted by internal combustion engines, a reliable, low-cost instrument for dynamic measurements of the exhaust emissions of ultrafine particulate matter (PM) is needed. In this study, an ordinary ionization-type building smoke detector was modified to serve as a measuring ionization chamber and utilized for dynamic measurements of PM emissions from diesel engines. When used with diluted exhaust, the readings show an excellent correlation with total particulate length. The instrument worked well with raw and diluted exhaust and with varying emission levels and is well suitable for on-board use. PMID:21387930

  4. Validation of the neutron and gamma fields in the JSI TRIGA reactor using in-core fission and ionization chambers.

    PubMed

    Žerovnik, Gašper; Kaiba, Tanja; Radulović, Vladimir; Jazbec, Anže; Rupnik, Sebastjan; Barbot, Loïc; Fourmentel, Damien; Snoj, Luka

    2015-02-01

    CEA developed fission chambers and ionization chambers were utilized at the JSI TRIGA reactor to measure neutron and gamma fields. The measured axial fission rate distributions in the reactor core are generally in good agreement with the calculated values using the Monte Carlo model of the reactor thus verifying both the computational model and the fission chambers. In future, multiple absolutely calibrated fission chambers could be used for more accurate online reactor thermal power monitoring. PMID:25479432

  5. Simulations of ^12C Break Up In A Twin Ionization Chamber

    NASA Astrophysics Data System (ADS)

    Segal, C. B.; Patel, N. R.; Greife, U.; Rehm, K. E.; Deibel, C. M.; Greene, J.; Henderson, D.; Jiang, C. L.; Kay, B. P.; Lee, H. Y.; Pardo, R.; Notani, M.; Marley, S. T.; Tang, X. D.

    2008-10-01

    In stellar explosions the triple α decay process is key to forming the life-giving ^12C . This experiment is to further investigate the energy region in ^12C around 10 MeV where a theoretically predicted 2^+ state has yet to be observed. The motivation for studying this is to better understand the ^12C nucleosynthesis process that occurs in red giant stars where the short lived ^8Be interacts with alphas at extreme temperature and pressure scenarios which then in turn creates ^12C. We study the particle-unbound states by implanting ^12B into a twin Frisch grid ionization chamber and following the decay into ^12C and subsequently into three α particles. The response of this ionization chamber to the detection of multiple α particles was studied using various simulation programs. Results of these simulations and limits for the predicted 2^+ state will be presented.

  6. Neutron and gamma detector using an ionization chamber with an integrated body and moderator

    DOEpatents

    Ianakiev, Kiril D.; Swinhoe, Martyn T.; Lestone, John Paul

    2006-07-18

    A detector for detecting neutrons and gamma radiation includes a cathode that defines an interior surface and an interior volume. A conductive neutron-capturing layer is disposed on the interior surface of the cathode and a plastic housing surrounds the cathode. A plastic lid is attached to the housing and encloses the interior volume of the cathode forming an ionization chamber, into the center of which an anode extends from the plastic lid. A working gas is disposed within the ionization chamber and a high biasing voltage is connected to the cathode. Processing electronics are coupled to the anode and process current pulses which are converted into Gaussian pulses, which are either counted as neutrons or integrated as gammas, in response to whether pulse amplitude crosses a neutron threshold. The detector according to the invention may be readily fabricated into single or multilayer detector arrays.

  7. Hard disk drive based microsecond X-ray chopper for characterization of ionization chambers and photodiodes.

    PubMed

    Müller, O; Lützenkirchen-Hecht, D; Frahm, R

    2015-03-01

    A fast X-ray chopper capable of producing ms long X-ray pulses with a typical rise time of few μs was realized. It is ideally suited to investigate the temporal response of X-ray detectors with response times of the order of μs to ms, in particular, any kind of ionization chambers and large area photo diodes. The drive mechanism consists of a brushless DC motor and driver electronics from a common hard disk drive, keeping the cost at an absolute minimum. Due to its simple construction and small dimensions, this chopper operates at home lab based X-ray tubes and synchrotron radiation sources as well. The dynamics of the most important detectors used in time resolved X-ray absorption spectroscopy, namely, ionization chambers and Passivated Implanted Planar Silicon photodiodes, were investigated in detail. The results emphasize the applicability of this X-ray chopper. PMID:25832273

  8. Hard disk drive based microsecond x-ray chopper for characterization of ionization chambers and photodiodes

    SciTech Connect

    Müller, O. Lützenkirchen-Hecht, D.; Frahm, R.

    2015-03-15

    A fast X-ray chopper capable of producing ms long X-ray pulses with a typical rise time of few μs was realized. It is ideally suited to investigate the temporal response of X-ray detectors with response times of the order of μs to ms, in particular, any kind of ionization chambers and large area photo diodes. The drive mechanism consists of a brushless DC motor and driver electronics from a common hard disk drive, keeping the cost at an absolute minimum. Due to its simple construction and small dimensions, this chopper operates at home lab based X-ray tubes and synchrotron radiation sources as well. The dynamics of the most important detectors used in time resolved X-ray absorption spectroscopy, namely, ionization chambers and Passivated Implanted Planar Silicon photodiodes, were investigated in detail. The results emphasize the applicability of this X-ray chopper.

  9. Application of the Shockley-Ramo theorem on the grid inefficiency of Frisch grid ionization chambers

    NASA Astrophysics Data System (ADS)

    Göök, A.; Hambsch, F.-J.; Oberstedt, A.; Oberstedt, S.

    2012-02-01

    The concept of grid inefficiency in Frisch grid ionization chambers and its influence on the anode pulse shape is explained in terms of the Shockley-Ramo theorem for induced charges. The grid inefficiency correction is deduced from numerically calculated weighting potentials. A method to determine the correction factor experimentally is also presented. Experimental and calculated values of the correction factor are shown to be in good agreement.

  10. Study of the replacement correction factors for ionization chamber dosimetry by Monte Carlo simulations

    NASA Astrophysics Data System (ADS)

    Wang, Lilie

    In ionization chamber radiation dosimetry, the introduction of the ion chamber into medium will unavoidably distort the radiation field near the chamber because the chamber cavity material (air) is different from the medium. A replacement correction factor, Prepl was introduced in order to correct the chamber readings to give an accurate radiation dose in the medium without the presence of the chamber. Generally it is very hard to measure the values of Prepl since they are intertwined with the chamber wall effect. In addition, the P repl values always come together with the stopping-power ratio of the two media involved. This makes the problem of determining the P repl values even more complicated. Monte Carlo simulation is an ideal method to investigate the replacement correction factors. In this study, four different methods of calculating the values of Prepl by Monte Carlo simulation are discussed. Two of the methods are designated as 'direct' methods in the sense that the evaluation of the stopping-power ratio is not necessary. The systematic uncertainties of the two direct methods are estimated to be about 0.1-0.2% which comes from the ambiguous definition of the energy cutoff Delta used in the Spencer-Attix cavity theory. The two direct methods are used to calculate the values of P repl for both plane-parallel chambers and cylindrical thimble chambers in either electron beams or photon beams. The calculation results are compared to measurements. For electron beams, good agreements are obtained. For thimble chambers in photon beams, significant discrepancies are observed between calculations and measurements. The experiments are thus investigated and the procedures are simulated by the Monte Carlo method. It is found that the interpretation of the measured data as the replacement correction factors in dosimetry protocols are not correct. In applying the calculation to the BIPM graphite chamber in a 60Co beam, the calculated values of P repl differ from those

  11. Dosimetric characteristics of the novel 2D ionization chamber array OCTAVIUS Detector 1500

    SciTech Connect

    Stelljes, T. S. Looe, H. K.; Chofor, N.; Poppe, B.; Harmeyer, A.; Reuter, J.; Harder, D.

    2015-04-15

    Purpose: The dosimetric properties of the OCTAVIUS Detector 1500 (OD1500) ionization chamber array (PTW-Freiburg, Freiburg, Germany) have been investigated. A comparative study was carried out with the OCTAVIUS Detector 729 and OCTAVIUS Detector 1000 SRS arrays. Methods: The OD1500 array is an air vented ionization chamber array with 1405 detectors in a 27 × 27 cm{sup 2} measurement area arranged in a checkerboard pattern with a chamber-to-chamber distance of 10 mm in each row. A sampling step width of 5 mm can be achieved by merging two measurements shifted by 5 mm, thus fulfilling the Nyquist theorem for intensity modulated dose distributions. The stability, linearity, and dose per pulse dependence were investigated using a Semiflex 31013 chamber (PTW-Freiburg, Freiburg, Germany) as a reference detector. The effective depth of measurement was determined by measuring TPR curves with the array and a Roos chamber type 31004 (PTW-Freiburg, Freiburg, Germany). Comparative output factor measurements were performed with the array, the Semiflex 31010 ionization chamber and the Diode 60012 (both PTW-Freiburg, Freiburg, Germany). The energy dependence of the OD1500 was measured by comparing the array’s readings to those of a Semiflex 31010 ionization chamber for varying mean photon energies at the depth of measurement, applying to the Semiflex chamber readings the correction factor k{sub NR} for nonreference conditions. The Gaussian lateral dose response function of a single array detector was determined by searching the convolution kernel suitable to convert the slit beam profiles measured with a Diode 60012 into those measured with the array’s central chamber. An intensity modulated dose distribution measured with the array was verified by comparing a OD1500 measurement to TPS calculations and film measurements. Results: The stability and interchamber sensitivity variation of the OD1500 array were within ±0.2% and ±0.58%, respectively. Dose linearity was within 1

  12. Comparative study of ionization chamber detectors vis-a-vis a CCD detector for dispersive XAS measurement in transmission geometry

    SciTech Connect

    Poswal, A. K.; Agrawal, A.; Bhattachryya, D.; Jha, S. N.; Sahoo, N. K.

    2013-02-05

    We have designed and fabricated parallel plate ionization chamber detectors and voltage vs. current characteristics (V-I curve) of the detectors were recorded with synchrotron radiation to qualify for use in X-ray Absorption Spectroscopy (XAS) measurements. After qualifying the ionization chambers, the detectors were used in the dispersive EXAFS beamline (BL-08) at INDUS-2 SRS in Turbo-XAS geometry. Using the same setup and under the same setting, XAS spectra were also recorded with a CCD detector and the observation on relative performance of the ionization chamber vis-a-vis the CCD detector is presented in this paper.

  13. Comparative study of ionization chamber detectors vis-à-vis a CCD detector for dispersive XAS measurement in transmission geometry

    NASA Astrophysics Data System (ADS)

    Poswal, A. K.; Agrawal, A.; Bhattachryya, D.; Jha, S. N.; Sahoo, N. K.

    2013-02-01

    We have designed and fabricated parallel plate ionization chamber detectors and voltage vs. current characteristics (V-I curve) of the detectors were recorded with synchrotron radiation to qualify for use in X-ray Absorption Spectroscopy (XAS) measurements. After qualifying the ionization chambers, the detectors were used in the dispersive EXAFS beamline (BL-08) at INDUS-2 SRS in Turbo-XAS geometry. Using the same setup and under the same setting, XAS spectra were also recorded with a CCD detector and the observation on relative performance of the ionization chamber vis-a-vis the CCD detector is presented in this paper.

  14. A position-sensitive twin ionization chamber for fission fragment and prompt neutron correlation experiments

    NASA Astrophysics Data System (ADS)

    Göök, A.; Geerts, W.; Hambsch, F.-J.; Oberstedt, S.; Vidali, M.; Zeynalov, Sh.

    2016-09-01

    A twin position-sensitive Frisch grid ionization chamber, intended as a fission fragment detector in experiments to study prompt fission neutron correlations with fission fragment properties, is presented. Fission fragment mass and energies are determined by means of the double kinetic energy technique, based on conservation of mass and linear momentum. The position sensitivity is achieved by replacing each anode plate in the standard twin ionization chamber by a wire plane and a strip anode, both readout by means of resistive charge division. This provides information about the fission axis orientation, which is necessary to reconstruct the neutron emission process in the fully accelerated fragment rest-frame. The energy resolution compared to the standard twin ionization chamber is found not to be affected by the modification. The angular resolution of the detector relative to an arbitrarily oriented axis is better than 7° FWHM. Results on prompt fission neutron angular distributions in 235U(n,f) obtained with the detector in combination with an array of neutron scintillation detectors is presented as a proof of principle.

  15. An evaluation of ionization chambers for the relative dosimetry of kilovoltage x-ray beams

    SciTech Connect

    Hill, Robin; Mo Zhao; Haque, Mamoon; Baldock, Clive

    2009-09-15

    In this work, the authors have evaluated ten different ionization chambers for the relative dosimetry of kilovoltage x-ray beams in the energy range of 50-280 kVp. Percentage depth doses in water and relative detector response (in Solid Water and in air) were measured for each of the x-ray beams studied using a number of chambers. Measured depth dose data were compared with Monte Carlo calculated depth doses using the EGSnrc Monte Carlo package and the BEAMnrc user code. The accuracy of the phase space files generated by BEAMnrc was verified by calculating the half-value layer and comparing with the measured half-value layer of each x-ray beam. The results indicate that the Advanced Markus, Markus, NACP, and Roos parallel plate ionization chambers were suitable for the measurement of depth dose data in this beam quality range with an uncertainty of less than 3%, including in the regions close to the water surface. While the relative detector response of the Farmer and scanning thimble chambers exhibited a better energy response, they were not suitable for depth dose measurements in the first 5 mm below the water surface with differences of up to 12% in the surface dose measurement for the 50 kVp x-ray beam. These differences were due to dose artifacts generated by the chamber size and the dose gradient. However, at depths greater than 5 mm, the Farmer and thimble scanning chambers gave uncertainties of less than 3% for the depth dose measurements for all beam energies. The PTW PinPoint 31006 chamber was found to give varying dose differences of up to 8% depending on the x-ray beam energy; this was attributed to the steel central electrode. The authors recommend that one of the parallel plate ionization chambers investigated be used to determine depth dose data for kilovoltage x-ray beams in the energy range studied and give correct dose information close to the surface and at depth in the water phantom.

  16. An ionization chamber with Frisch grids for studies of high-energy neutron-induced fission

    NASA Astrophysics Data System (ADS)

    Tutin, G. A.; Ryzhov, I. V.; Eismont, V. P.; Kireev, A. V.; Condé, H.; Elmgren, K.; Olsson, N.; Renberg, P.-U.

    2001-01-01

    A gridded ionization chamber for fission fragment detection is described. The chamber has been specially designed for use at the quasi-monoenergetic 7Li(p, n) neutron source at the The Svedberg Laboratory, Uppsala, Sweden. The detector permits measurements of fission fragment energy and emission angle for two targets with diameter of up to 10 cm. The time response of the chamber (⩽5 ns FWHM) is adequate to apply time-of-flight discrimination against background events induced by non-peak neutrons. Results of angular anisotropy measurements for the 232Th (n, f) and 238U(n, f) reactions in the 20-160 MeV energy range are given.

  17. Theoretical study of Jesse effect in tritium measurements using ionization chambers

    NASA Astrophysics Data System (ADS)

    Chen, Zhilin; Peng, Shuming; Lu, Hanghang; Tan, Zhaoyi; Wang, Heyi; Long, Xingui; Masao, Matsuyama

    2016-01-01

    Jesse effect caused by impurities in helium might enhance the output signal significantly in tritium measurements with ionization chamber, which will lead to overestimation of tritium concentration in experiments. A theoretical method was proposed to evaluate Jesse effect quantitatively. Results indicate that besides Penning ionization, sub-excitation electrons also place very important influence on ionization enhancement by Jesse effect. An experiential expression about the relationship between enhancement factor and impurity concentration was established, in which second order of it fits experimental results very well. Theoretical calculation method in this paper is also applicable to evaluate Jesse effect in other kinds of mixtures besides hydrogen as impurities in helium. In addition, Jesse effects about tritium molecules as impurities have also been investigated.

  18. An online proton beam monitor for cancer therapy based on ionization chambers with micro pattern readout

    NASA Astrophysics Data System (ADS)

    Basile, E.; Carloni, A.; Castelluccio, D. M.; Cisbani, E.; Colilli, S.; De Angelis, G.; Fratoni, R.; Frullani, S.; Giuliani, F.; Gricia, M.; Lucentini, M.; Santavenere, F.; Vacca, G.

    2012-03-01

    A unique compact LINAC accelerator for proton therapy is under development in Italy within the TOP-IMPLART project. The proton beam will reach the kinetic energy of 230 MeV, it will have a widely variable current intensity (0.1-10 μA, with average up to 3.5 nA) associated with a high pulse repetition frequency (1-3.5 μs long pulses at 10-100 Hz). The TOP-IMPLART system will provide a fully active 3+1D dose delivery, that is longitudinal (energy modulation), transverse active spot scanning, and current intensity modulation. These accelerator features will permit a highly conformational dose distribution, which therefore requires an effective, online, beam monitor system with wide dynamic range, good sensitivity, adequate spatial resolution and rapid response. In order to fulfill these requisites a new device is under development for the monitoring of the beam intensity profile, its centroid and direction; it is based on transmission, segmented, ionization chambers with typical active area of 100 × 100 mm2. Micro pattern x/y pad like design has been used for the readout plane in order to maximize the field uniformity, reduce the chamber thickness and obtain both beam coordinates on a single chamber. The chamber prototype operates in ionization region to minimize saturation and discharge effects. Simulations (based on FLUKA) have been carried on to study the perturbation of the chamber on the beam parameters and the effects on the delivered dose (on a water phantom). The charge collected in each channel is integrated by dedicated auto-ranging readout electronics: an original scheme has been developed in order to have an input dynamic range greater than 104 with sensitivity better than 3%. This is achieved by a dynamical adjustment of the integrating capacitance to the signal intensity.

  19. Large-angle ionization chambers for brachytherapy air-kerma-strength measurements

    NASA Astrophysics Data System (ADS)

    Culberson, Wesley S.

    There has been a significant increase in the use of low-energy photon-emitting radionuclides in the past decade to treat cancer with a special form of radiation therapy called brachytherapy. For treating prostate cancer, brachytherapy sources are approximately the size of a grain of rice and are normally radioactive 125I or 103Pd sources encapsulated in titanium or plastic. Although these sources have proven effective in the treatment of cancer, the clinical dosimetry is difficult due to the unique varieties available and their typically. A large-angle free-air chamber at the National Institute of Standards and Technology (NIST) called the Wide-Angle Free-Air Chamber (WAFAC) is the current standard for measuring the strength of low-energy photon-emitting radionuclides for brachytherapy. This chamber has served the clinical medical physics community well and is a significant improvement over previous standards. However, it has some shortcomings. This thesis describes the development of a new large-angle ionization chamber at the University of Wisconsin called the Variable-Aperture Free-Air Chamber (VAFAC) to measure brachytherapy sources with extended capabilities. This chamber is constructed to explore characteristics in the calibration of brachytherapy seeds by quantifying potential variations caused by anisotropy and the change in response with integration angle. In addition, the characterization of yet another large-angle free-air chamber called the Grossvolumen Extrapolationskammer (GROVEX) in the German national standards institute Physikalisch-Technische Bundesanstalt (PTB) is also presented. The objective of this thesis is to present improved measurement techniques with free-air ionization chambers that will improve the accuracy of the dose delivered to patients. First, it will be shown that the UW VAFAC is capable of measuring conventional 125I or 103Pd seeds as well as longer sources, coiled sources, and miniature x-ray tubes. Additionally, the VAFAC

  20. Ion recombination corrections of ionization chambers in flattening filter-free photon radiation.

    PubMed

    Wang, Yuenan; Easterling, Stephen B; Ting, Joseph Y

    2012-01-01

    The flattening filter free (FFF) X-rays can provide much higher dose rate at the treatment target compared to the conventional flattened X-rays. However, the substantial increase of dose rate for FFF beams may affect the ion recombination correction factor, which is required for accurate measurements using ionization chambers in clinical dosimetry. The purpose of this work is to investigate the ion recombination of three types of commonly used ion chambers (Farmer, PinPoint and plane-parallel) in the FFF photon radiation. Both 6 MV and 10 MV flattened and FFF beams were fully commissioned on a Varian TrueBeam linear accelerator. The ion recombination correction factor, P(ion), was determined using the two-voltage technique for a 0.6 cc Farmer chamber, a 0.015 cc PinPoint chamber, and a 0.02 cc parallel-plate chamber at different source-to-axis distances (SAD) in a solid water phantom or water tank phantom at a depth of 10 cm in a 10 × 10 cm(2) field. Good repeatability of measurements was demonstrated. Less than 1% difference in P(ion) between the flattened and FFF photons for all three ion chambers was observed. At a SAD of 100 cm and a depth of 10 cm for a 10 × 10 cm(2) field, P(ion) for the Farmer chamber was 1.004 and 1.008 for the 6 MV flattened and FFF beams, respectively. At the same setup using the Farmer chamber, P(ion) was 1.002 and 1.015 for the 10MV flattened and FFF beams, respectively. All P(ion) results for the Farmer, PinPoint, or parallel plate chamber in the 6 MV and 10 MV flattened and FFF beams were within 2% from the unity (1 ≤ P(ion) < 1.02). The P(ion) ratio of the FFF to flattened beams was 0.99~1.01 for both 6 MV and 10 MV photons. The ion recombination effect of the Farmer, PinPoint, and plane-parallel chamber in the FFF beams is not substantially different from that in the conventional flattened beams. PMID:22955642

  1. Use of relativistic rise in ionization chambers for measurement of high energy heavy nuclei

    NASA Technical Reports Server (NTRS)

    Barthelmy, S. D.; Israel, M. H.; Klarmann, J.; Vogel, J. S.

    1983-01-01

    A balloon-borne instrument has been constructed to measure the energy spectra of cosmic-ray heavy nuclei in the range of about 0.3 to about 100 GeV/amu. It makes use of the relativistic rise portion of the Bethe-Bloch curve in ionization chambers for energy determination in the 10- to 100-GeV/amu interval. The instrument consists of six layers of dual-gap ionization chambers for energy determination above 10 GeV/amu. Charge is determined with a NE114 scintillator and a Pilot 425 plastic Cerenkov counter. A CO2 gas Cerenkov detector (1 atm; threshold of 30 GeV/amu) calibrates the ion chambers in the relativistic rise region. The main emphasis of the instrument is the determination of the change of the ratio of Iron (26) to the Iron secondaries (21-25) in the energy range of 10 to 100 GeV/amu. Preliminary data from a balloon flight in the fall of 1982 from Palestine, TX is presented.

  2. Influence of field size on a PTW type 23342 plane-parallel ionization chamber's response

    SciTech Connect

    Austerlitz, C.; Villar, H.P.; Santos, M.A.P.

    2004-12-01

    The response of a PTW type 23342 plane-parallel ionization chamber, both in air and in phantom, was evaluated for x-ray tube potentials between 30 and 100 kV and radiation field diameters ranging from 30 to 70 mm. The experiments were performed with a calibrated Pantak x-ray machine and made use of the same set of x-ray qualities adopted by the PTB primary laboratory for the calibration of such chambers. A Plexiglas registered phantom (1.18 g cm{sup -3}) 110 mm long, 110 mm wide, and 80 mm deep was used for phantom measurements. X-ray qualities were characterized by using 99.99% pure aluminum filters. On the basis of the IAEA's TRS 398, the article discusses the dependence of the plane-parallel ionization chamber readings with field size in air and in phantom, its implication with regard to clinical dosimetry, cross-calibration, and dissemination of calibration factors.

  3. Measurement of photon flux with a miniature gas ionization chamber in a Material Testing Reactor

    NASA Astrophysics Data System (ADS)

    Fourmentel, D.; Filliatre, P.; Villard, J. F.; Lyoussi, A.; Reynard-Carette, C.; Carcreff, H.

    2013-10-01

    Nuclear heating measurements in Material Testing Reactors (MTR) are crucial for the design of the experimental devices and the prediction of the temperature of the hosted samples. Nuclear heating in MTR materials (except fuel) is mainly due to the energy deposition by the photon flux. Therefore, the photon flux is a key input parameter for the computer codes which simulate nuclear heating and temperature reached by samples/devices under irradiation. In the Jules Horowitz MTR under construction at the CEA Cadarache, the maximal expected nuclear heating levels will be about 15 to 18 W g-1 and it will be necessary to assess this parameter with the best accuracy. An experiment was performed at the OSIRIS reactor to combine neutron flux, photon flux and nuclear heating measurements to improve the knowledge of the nuclear heating in MTR. There are few appropriate sensors for selective measurement of the photon flux in MTR even if studies and developments are ongoing. An experiment, called CARMEN-1, was conducted at the OSIRIS MTR and we used in particular a gas ionization chamber based on miniature fission chamber design to measure the photon flux. In this paper, we detail Monte-Carlo simulations to analyze the photon fluxes with ionization chamber measurements and we compare the photon flux calculations to the nuclear heating measurements. These results show a good accordance between photon flux measurements and nuclear heating measurement and allow improving the knowledge of these parameters.

  4. Monte Carlo calculations of correction factors for plane-parallel ionization chambers in clinical electron dosimetry

    SciTech Connect

    Araki, Fujio

    2008-09-15

    Recent standard dosimetry protocols recommend that plane-parallel ionization chambers be used in the measurements of depth-dose distributions or the calibration of low-energy electron beams with beam quality R{sub 50}<4 g/cm{sup 2}. In electron dosimetry protocols with the plane-parallel chambers, the wall correction factor, P{sub wall}, in water is assumed to be unity and the replacement correction factor, P{sub repl}, is taken to be unity for well-guarded plane-parallel chambers, at all measurement depths. This study calculated P{sub wall} and P{sub repl} for NACP-02, Markus, and Roos plane-parallel chambers in clinical electron dosimetry using the EGSnrc Monte Carlo code system. The P{sub wall} values for the plane-parallel chambers increased rapidly as a function of depth in water, especially at lower energy. The value around R{sub 50} for NACP-02 was about 10% greater than unity at 4 MeV. The effect was smaller for higher electron energies. Similarly, P{sub repl} values with depth increased drastically at the region with the steep dose gradient for lower energy. For Markus P{sub repl} departed more than 10% from unity close to R{sub 50} due to the narrow guard ring width. P{sub repl} for NACP-02 and Roos was close to unity in the plateau region of depth-dose curves that includes a reference depth, d{sub ref}. It was also found that the ratio of the dose to water and the dose to the sensitive volume in the air cavity for the plane-parallel chambers, D{sub w}/[D{sub air}]{sub pp}, at d{sub ref} differs significantly from that assumed by electron dosimetry protocols.

  5. Ambiguities in the grid-inefficiency correction for Frisch-Grid Ionization Chambers

    NASA Astrophysics Data System (ADS)

    Al-Adili, A.; Hambsch, F.-J.; Bencardino, R.; Oberstedt, S.; Pomp, S.

    2012-05-01

    Ionization chambers with Frisch grids have been very successfully applied to neutron-induced fission-fragment studies during the past 20 years. They are radiation resistant and can be easily adapted to the experimental conditions. The use of Frisch grids has the advantage to remove the angular dependency from the charge induced on the anode plate. However, due to the Grid Inefficiency (GI) in shielding the charges, the anode signal remains slightly angular dependent. The correction for the GI is, however, essential to determine the correct energy of the ionizing particles. GI corrections can amount to a few percent of the anode signal. Presently, two contradicting correction methods are considered in literature. The first method adding the angular-dependent part of the signal to the signal pulse height; the second method subtracting the former from the latter. Both additive and subtractive approaches were investigated in an experiment where a Twin Frisch-Grid Ionization Chamber (TFGIC) was employed to detect the spontaneous fission fragments (FF) emitted by a 252Cf source. Two parallel-wire grids with different wire spacing (1 and 2 mm, respectively), were used individually, in the same chamber side. All the other experimental conditions were unchanged. The 2 mm grid featured more than double the GI of the 1 mm grid. The induced charge on the anode in both measurements was compared, before and after GI correction. Before GI correction, the 2 mm grid resulted in a lower pulse-height distribution than the 1 mm grid. After applying both GI corrections to both measurements only the additive approach led to consistent grid independent pulse-height distributions. The application of the subtractive correction on the contrary led to inconsistent, grid-dependent results. It is also shown that the impact of either of the correction methods is small on the FF mass distributions of 235U(nth, f).

  6. Multi-Sampling Ionization Chamber (MUSIC) for measurements of fusion reactions with radioactive beams

    NASA Astrophysics Data System (ADS)

    Carnelli, P. F. F.; Almaraz-Calderon, S.; Rehm, K. E.; Albers, M.; Alcorta, M.; Bertone, P. F.; Digiovine, B.; Esbensen, H.; Fernández Niello, J.; Henderson, D.; Jiang, C. L.; Lai, J.; Marley, S. T.; Nusair, O.; Palchan-Hazan, T.; Pardo, R. C.; Paul, M.; Ugalde, C.

    2015-11-01

    A detection technique for high-efficiency measurements of fusion reactions with low-intensity radioactive beams was developed. The technique is based on a Multi-Sampling Ionization Chamber (MUSIC) operating as an active target and detection system, where the ionization gas acts as both target and counting gas. In this way, we can sample an excitation function in an energy range determined by the gas pressure, without changing the beam energy. The detector provides internal normalization to the incident beam and drastically reduces the measuring time. In a first experiment we tested the performance of the technique by measuring the 10,13,15C+12C fusion reactions at energies around the Coulomb barrier.

  7. Application of patent BR102013018500-0 in well type ionization chambers

    NASA Astrophysics Data System (ADS)

    Sousa, C. H. S.; Peixoto, J. G. P.

    2016-07-01

    The definition of the radioactive sample position in a well type ionization chamber is the largest source of uncertainty in the measurement of quantity activity. The determination of this parameter in two activimeters helped to improve their accuracies, from 2.62 and 2.59% to 3.87 and 1.74%, with and without the use of the positioning device, concluding, that with their use has reached an uncertainty of U =2276 and 0.2677% (k = 2) 95.45%.

  8. Strip Ionization Chamber as Beam Monitor in the Proton Therapy Eye Treatment

    NASA Astrophysics Data System (ADS)

    Marchetto, F.; Cirio, R.; Garella, M. A.; Giordanengo, S.; Boriano, A.; Givehchi, N.; La Rosa, A.; Peroni, C.; Donetti, M.; Bourhaleb, F.; Pitta', G.; Cirrone, G. A. P.; Cuttone, G.; Raffaele, L.; Sabini, M. G.; Valastro, L.

    2006-04-01

    Since spring 2002, ocular pathologies have been treated in Catania at the Centro di AdroTerapia e Applicazioni Nucleari Avanzate (CATANA) within a collaboration between INFN Laboratori Nazionali del Sud (LNS), Physics Department, Ophthalmology Institute, Radiology Institute of the Catania University and CSFNSM Catania. A beam line from a 62 MeV Superconducting Cyclotron is used to treat shallow tumors. The beam is conformed to the tumor shape with a passive delivery system. A detector system has been developed in collaboration with INFN-Torino to be used as real time beam monitor. The detector, placed upstream of the patient collimator, consists of two parallel plate ionization chambers with the anode segmented in strips. Each anode is made of 0.5 mm-wide 256 strips corresponding to (12.8 × 12.8) cm2 sensitive area. With the two strip ionization chambers one can measure the relevant beam parameters during treatment to probe both asymmetry and flatness. In the test carried out at CATANA the detector has been used under different and extreme beam conditions. Preliminary results are given for profiles and skewness, together with a comparison with reference detectors.

  9. Liquid ionization chamber measurements of dose distributions in small 6 MV photon beams

    NASA Astrophysics Data System (ADS)

    Dasu, Alexandru; Löfroth, Per-Olov; Wickman, Göran

    1998-01-01

    A new liquid ionization chamber (LIC) design optimized for high spatial resolution was used for measurements of dose distributions in radiation fields intended for stereotactic radiosurgery (SRS). This work was mainly focused on the properties of this detector in radiation fields from linear accelerators for clinical radiotherapy (pulsed radiation with dose rates from approximately 0.5 to and beam diameters down to 8 mm). The narrow beams used in stereotactic radiosurgery require detectors with small sizes in order to provide a good spatial resolution. The LIC is investigated to see whether it can be used as a detector for dose measurements in beams currently used for stereotactic radiosurgery. Its properties are compared with those of silicon diodes. The comparisons include output factor (OF), depth dose and profile measurements in 6 MV photon fields of different sizes. For OF measurements, an NACP air ionization chamber was also used in the comparison. The dependence of the response on the detector orientation in the photon beam is also investigated for the diodes and the LIC. The results suggest that LICs can provide better properties than diodes for measuring dose distributions in narrow photon beams.

  10. DNP for polarizing liquid {sup 3}He

    SciTech Connect

    Uemtasu, H.; Iwata, T.; Kato, S.; Michigami, T.; Ohizumi, S.; Shishido, T.; Tanaka, A.; Toyama, K.; Tajima, Y.; Yoshida, H. Y.; Kuriyama, N.

    2008-02-06

    Using DNP with zeolite powders and TEMPO, we have developed a method to enhance polarization of liquid {sup 3}He. At magnetic field of 2.5 T and a temperature of around 1.5 K, we have obatined polarization enhancement of liquid {sup 3}He, 2.34 and -1.59 for positive and negative enhancements, respectively.

  11. Technical Note: Experimental determination of the effective point of measurement of two cylindrical ionization chambers in a clinical proton beam

    SciTech Connect

    Sugama, Yuya; Nishio, Teiji; Onishi, Hiroshi

    2015-07-15

    Purpose: IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement of 0.75 times the inner cavity radius (0.75R) for heavy ion beams. Theoretical models by Palmans and by Bhullar and Watchman confirmed this value. However, the experimental results vary from author to author. The purpose of this study is to accurately measure the displacement and explain the past experimental discrepancies. Methods: In this work, we measured the EPOM of cylindrical ionization chambers with high accuracy by comparing the Bragg-peak position obtained with cylindrical ionization chambers (PTW 30013, PTW 31016) to that obtained using a plane-parallel ionization chamber (PTW 34045). Results: The EPOMs of PTW 30013 and 31016 were shifted by 0.92 ± 0.07 R with R = 3.05 mm and 0.90 ± 0.14 R with R = 1.45 mm, respectively, from the reference point toward the source. Conclusions: The EPOMs obtained were greater than the value of 0.75R proposed by the IAEA TRS-398 and the analytical results.

  12. Vortices in rotating superfluid 3He.

    PubMed

    Lounasmaa, O V; Thuneberg, E

    1999-07-01

    In this review we first present an introduction to 3He and to the ROTA collaboration under which most of the knowledge on vortices in superfluid 3He has been obtained. In the physics part, we start from the exceptional properties of helium at millikelvin temperatures. The dilemma of rotating superfluids is presented. In 4He and in 3He-B the problem is solved by nucleating an array of singular vortex lines. Their experimental detection in 3He by NMR is described next. The vortex cores in 3He-B have two different structures, both of which have spontaneously broken symmetry. A spin-mass vortex has been identified as well. This object is characterized by a flow of spins around the vortex line, in addition to the usual mass current. A great variety of vortices exist in the A phase of 3He; they are either singular or continuous, and their structure can be a line or a sheet or fill the whole liquid. Altogether seven different types of vortices have been detected in 3He by NMR. We also describe briefly other experimental methods that have been used by ROTA scientists in studying vortices in 3He and some important results thus obtained. Finally, we discuss the possible applications of experiments and theory of 3He to particle physics and cosmology. In particular, we report on experiments where superfluid 3He-B was heated locally by absorption of single neutrons. The resulting events can be used to test theoretical models of the Big Bang at the beginning of our universe. PMID:10393895

  13. Vortices in rotating superfluid 3He

    PubMed Central

    Lounasmaa, Olli V.; Thuneberg, Erkki

    1999-01-01

    In this review we first present an introduction to 3He and to the ROTA collaboration under which most of the knowledge on vortices in superfluid 3He has been obtained. In the physics part, we start from the exceptional properties of helium at millikelvin temperatures. The dilemma of rotating superfluids is presented. In 4He and in 3He-B the problem is solved by nucleating an array of singular vortex lines. Their experimental detection in 3He by NMR is described next. The vortex cores in 3He-B have two different structures, both of which have spontaneously broken symmetry. A spin-mass vortex has been identified as well. This object is characterized by a flow of spins around the vortex line, in addition to the usual mass current. A great variety of vortices exist in the A phase of 3He; they are either singular or continuous, and their structure can be a line or a sheet or fill the whole liquid. Altogether seven different types of vortices have been detected in 3He by NMR. We also describe briefly other experimental methods that have been used by ROTA scientists in studying vortices in 3He and some important results thus obtained. Finally, we discuss the possible applications of experiments and theory of 3He to particle physics and cosmology. In particular, we report on experiments where superfluid 3He-B was heated locally by absorption of single neutrons. The resulting events can be used to test theoretical models of the Big Bang at the beginning of our universe. PMID:10393895

  14. A new standard cylindrical graphite-walled ionization chamber for dosimetry in 60Co beams at calibration laboratories

    NASA Astrophysics Data System (ADS)

    Neves, Lucio P.; Perini, Ana P.; Caldas, Linda V. E.

    2014-11-01

    60Co sources are used mostly at dosimetry laboratories for calibration of ionization chambers utilized for radiotherapy dosimetry, mainly in those laboratories where there is no linear accelerator available. In this work, a new cylindrical ionization chamber was developed and characterized to be used as a reference dosimeter at the Calibration Laboratory of the IPEN. The characterization tests were performed according to the IEC 60731 standard, and all tests presented results within its recommended limits. Furthermore, the correction factors for the wall, stem, central collecting electrode, nonaxial uniformity and the mass-energy absorption coefficient were determined using the EGSnrc Monte Carlo code. The air kerma rate determined with this new dosimeter was compared to the one obtained with the IPEN standard, presenting a difference of 1.5%. Therefore, the new ionization chamber prototype developed and characterized in this work presents potential use as a primary standard dosimeter at radiation metrology laboratories.

  15. Determination of small-field correction factors for cylindrical ionization chambers using a semiempirical method

    NASA Astrophysics Data System (ADS)

    Park, Kwangwoo; Bak, Jino; Park, Sungho; Choi, Wonhoon; Park, Suk Won

    2016-02-01

    A semiempirical method based on the averaging effect of the sensitive volumes of different air-filled ionization chambers (ICs) was employed to approximate the correction factors for beam quality produced from the difference in the sizes of the reference field and small fields. We measured the output factors using several cylindrical ICs and calculated the correction factors using a mathematical method similar to deconvolution; in the method, we modeled the variable and inhomogeneous energy fluence function within the chamber cavity. The parameters of the modeled function and the correction factors were determined by solving a developed system of equations as well as on the basis of the measurement data and the geometry of the chambers. Further, Monte Carlo (MC) computations were performed using the Monaco® treatment planning system to validate the proposed method. The determined correction factors (k{{Q\\text{msr}},Q}{{f\\text{smf}}, {{f}\\text{ref}}} ) were comparable to the values derived from the MC computations performed using Monaco®. For example, for a 6 MV photon beam and a field size of 1  ×  1 cm2, k{{Q\\text{msr}},Q}{{f\\text{smf}}, {{f}\\text{ref}}} was calculated to be 1.125 for a PTW 31010 chamber and 1.022 for a PTW 31016 chamber. On the other hand, the k{{Q\\text{msr}},Q}{{f\\text{smf}}, {{f}\\text{ref}}} values determined from the MC computations were 1.121 and 1.031, respectively; the difference between the proposed method and the MC computation is less than 2%. In addition, we determined the k{{Q\\text{msr}},Q}{{f\\text{smf}}, {{f}\\text{ref}}} values for PTW 30013, PTW 31010, PTW 31016, IBA FC23-C, and IBA CC13 chambers as well. We devised a method for determining k{{Q\\text{msr}},Q}{{f\\text{smf}}, {{f}\\text{ref}}} from both the measurement of the output factors and model-based mathematical computation. The proposed method can be useful in case the MC simulation would not be applicable for the clinical settings.

  16. Spin Duality on the Neutron (^3He)

    SciTech Connect

    Solvignon, Patricia

    2007-02-01

    Thomas Jefferson National Accelerator Facility experiment E01-012 measured the 3He spin structure functions and virtual photon asymmetries in the resonance region in the momentum transfer range 1.0 < Q2 < 4.0 (GeV/c)2. Our date, when compared with existing deep inelastic scattering data, can be used to test quark-hadron duality in g1 and A1 for 3He and the neutron. Preliminary results for A{sub 1}{sup {sup 3}He} are presented, as well as some details about the experiment.

  17. Performance of a multi-axis ionization chamber array in a 1.5 T magnetic field

    NASA Astrophysics Data System (ADS)

    Smit, K.; Kok, J. G. M.; Lagendijk, J. J. W.; Raaymakers, B. W.

    2014-04-01

    At the UMC Utrecht a prototype MR-linac has been installed. The system consists of an 8 MV Elekta linear accelerator and a 1.5 T Philips MRI system. This paper investigates the performance of the IC PROFILER™, a multi-axis ionization chamber array, in a 1.5 T magnetic field. The influence of the magnetic field on the IC PROFILER™ reproducibility, dose response linearity, pulse rate frequency dependence, power to electronics, panel orientation and ionization chamber shape were investigated. The linearity, reproducibility, pulse rate frequency dependence, panel orientation and ionization chamber shape are unaffected by the magnetic field. When the measurements results are normalized to the centre reference chamber, the measurements can commence unaltered. Orientation of the ionization chambers in the magnetic field is of importance, therefore caution must be taken when comparing or normalizing results from several different axes. IC PROFILER™ dose profiles were compared with film dose profiles obtained simultaneously in the MR-linac. Deviation between the film and the IC PROFILER™ data was caused by the noise in the film, indicating correct performance of the IC PROFILER™ in the transverse 1.5 T magnetic field.

  18. Beta and Gamma Correction Factors for the Eberline R0-20 Ionization Chamber Survey Instrument

    SciTech Connect

    Johnson, Michelle L.; Rathbone, Bruce A.; Bratvold, Thomas E.

    2001-08-10

    This technical document provides details of derived correction factors for the Eberline R0-20 survey meter, which uses an ionization chamber to measure ambient exposure rates. A thin end window allows the instrument to measure exposure rates from non-penetrating radiation (i.e., beta radiation). Correction factors are provided for contact measurements with beta and gamma disk sources, gamma beams and, finally, general area beta fields. Beta correction factors are based on the instrument's response to 204Tl, selected as the most conservative isotope for beta correction factors, as indicated in previous studies of similar instruments using 204Tl, 147Pm, and 90Sr(Y) isotopes (LANL 1982). Gamma correction factors are based on 137Cs, considered the predominant source of gamma radiation on the Hanford Site.

  19. Particle emission angle determination in Frisch grid ionization chambers by electron drift-time measurements

    NASA Astrophysics Data System (ADS)

    Göök, A.; Chernykh, M.; Enders, J.; Oberstedt, A.; Oberstedt, S.

    2010-09-01

    The double kinetic energy measurement of fission fragments with a double-sided Frisch grid ionization chamber allows a careful determination of the emission angle, which is essential in order to apply appropriate energy-loss corrections. We present a drift-time method, which uses the time that free electrons need to drift from the location of their creation, e.g. by a fission fragment in the counting gas, to the grid, before inducing a signal on the anode. Such a measurement leaves energy and angular information fully decoupled. We demonstrate the applicability of the drift-time method for the example of the 234,238U (γ,f) reactions performed at the superconducting Darmstadt electron linear accelerator. The angular resolutions achieved with this method are comparable to those obtained with other methods.

  20. The mass dependence of the signal peak height of a Bragg-curve ionization chamber

    NASA Astrophysics Data System (ADS)

    Shenhav, N. J.; Stelzer, H.

    1985-01-01

    The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required.

  1. Energy resolution of gas ionization chamber for high-energy heavy ions

    NASA Astrophysics Data System (ADS)

    Sato, Yuki; Taketani, Atsushi; Fukuda, Naoki; Takeda, Hiroyuki; Kameda, Daisuke; Suzuki, Hiroshi; Shimizu, Yohei; Nishimura, Daiki; Fukuda, Mitsunori; Inabe, Naohito; Murakami, Hiroyuki; Yoshida, Koichi; Kubo, Toshiyuki

    2014-01-01

    The energy resolution is reported for high-energy heavy ions with energies of nearly 340 MeV/nucleon and was measured using a gas ionization chamber filled with a 90%Ar/10%CH4 gas mixture. We observed that the energy resolution is proportional to the inverse of the atomic number of incident ions and to the inverse-square-root of the gas thickness. These results are consistent with the Bethe-Bloch formula for the energy loss of charged particles and the Bohr expression for heavy ion energy straggling. In addition, the influence of high-energy δ-rays generated in the detector on the energy deposition is discussed.

  2. Comparison of pencil-type ionization chamber calibration results and methods between dosimetry laboratories.

    PubMed

    Hourdakis, Costas J; Büermann, Ludwig; Ciraj-Bjelac, Olivera; Csete, Istvan; Delis, Harry; Gomola, Igor; Persson, Linda; Novak, Leos; Petkov, Ivailo; Toroi, Paula

    2016-01-01

    A comparison of calibration results and procedures in terms of air kerma length product, PKL, and air kerma, K, was conducted between eight dosimetry laboratories. A pencil-type ionization chamber (IC), generally used for computed tomography dose measurements, was calibrated according to three calibration methods, while its residual signal and other characteristics (sensitivity profile, active length) were assessed. The results showed that the "partial irradiation method" is the preferred method for the pencil-type IC calibration in terms of PKL and it could be applied by the calibration laboratories successfully. Most of the participating laboratories achieved high level of agreement (>99%) for both dosimetry quantities (PKL and K). Estimated relative standard uncertainties of comparison results vary among laboratories from 0.34% to 2.32% depending on the quantity, beam quality and calibration method applied. Detailed analysis of the assigned uncertainties have been presented and discussed. PMID:26508013

  3. Quality assurance of proton beams using a multilayer ionization chamber system

    SciTech Connect

    Dhanesar, Sandeep; Sahoo, Narayan; Kerr, Matthew; Taylor, M. Brad; Summers, Paige; Zhu, X. Ronald; Poenisch, Falk; Gillin, Michael

    2013-09-15

    Purpose: The measurement of percentage depth-dose (PDD) distributions for the quality assurance of clinical proton beams is most commonly performed with a computerized water tank dosimetry system with ionization chamber, commonly referred to as water tank. Although the accuracy and reproducibility of this method is well established, it can be time-consuming if a large number of measurements are required. In this work the authors evaluate the linearity, reproducibility, sensitivity to field size, accuracy, and time-savings of another system: the Zebra, a multilayer ionization chamber system.Methods: The Zebra, consisting of 180 parallel-plate ionization chambers with 2 mm resolution, was used to measure depth-dose distributions. The measurements were performed for scattered and scanned proton pencil beams of multiple energies delivered by the Hitachi PROBEAT synchrotron-based delivery system. For scattered beams, the Zebra-measured depth-dose distributions were compared with those measured with the water tank. The principal descriptors extracted for comparisons were: range, the depth of the distal 90% dose; spread-out Bragg peak (SOBP) length, the region between the proximal 95% and distal 90% dose; and distal-dose fall off (DDF), the region between the distal 80% and 20% dose. For scanned beams, the Zebra-measured ranges were compared with those acquired using a Bragg peak chamber during commissioning.Results: The Zebra demonstrated better than 1% reproducibility and monitor unit linearity. The response of the Zebra was found to be sensitive to radiation field sizes greater than 12.5 × 12.5 cm; hence, the measurements used to determine accuracy were performed using a field size of 10 × 10 cm. For the scattered proton beams, PDD distributions showed 1.5% agreement within the SOBP, and 3.8% outside. Range values agreed within −0.1 ± 0.4 mm, with a maximum deviation of 1.2 mm. SOBP length values agreed within 0 ± 2 mm, with a maximum deviation of 6 mm. DDF

  4. Dependence with air density of the response of the PTW SourceCheck ionization chamber for low energy brachytherapy sources

    SciTech Connect

    Tornero-López, Ana M.; Guirado, Damián; Ruiz-Arrebola, Samuel; Perez-Calatayud, Jose; Simancas, Fernando; Lallena, Antonio M.; Gazdic-Santic, Maja

    2013-12-15

    Purpose: Air-communicating well ionization chambers are commonly used to assess air kerma strength of sources used in brachytherapy. The signal produced is supposed to be proportional to the air density within the chamber and, therefore, a density-independent air kerma strength is obtained when the measurement is corrected to standard atmospheric conditions using the usual temperature and pressure correction factor. Nevertheless, when assessing low energy sources, the ionization chambers may not fulfill that condition and a residual density dependence still remains after correction. In this work, the authors examined the behavior of the PTW 34051 SourceCheck ionization chamber when measuring the air kerma strength of {sup 125}I seeds.Methods: Four different SourceCheck chambers were analyzed. With each one of them, two series of measurements of the air kerma strength for {sup 125}I selectSeed{sup TM} brachytherapy sources were performed inside a pressure chamber and varying the pressure in a range from 747 to 1040 hPa (560 to 780 mm Hg). The temperature and relative humidity were kept basically constant. An analogous experiment was performed by taking measurements at different altitudes above sea level.Results: Contrary to other well-known ionization chambers, like the HDR1000 PLUS, in which the temperature-pressure correction factor overcorrects the measurements, in the SourceCheck ionization chamber they are undercorrected. At a typical atmospheric situation of 933 hPa (700 mm Hg) and 20 °C, this undercorrection turns out to be 1.5%. Corrected measurements show a residual linear dependence on the density and, as a consequence, an additional density dependent correction must be applied. The slope of this residual linear density dependence is different for each SourceCheck chamber investigated. The results obtained by taking measurements at different altitudes are compatible with those obtained with the pressure chamber.Conclusions: Variations of the altitude and

  5. A new generation of 3He refrigerators

    NASA Astrophysics Data System (ADS)

    Graziani, A.; DalĺOglio, G.; Martinis, L.; Pizzo, L.; Sabbatini, L.

    2003-12-01

    The characteristics and performance of a new class of 3He refrigerators are discussed. We introduce a 3He refrigerator, which allows a temperature of 296 m K to be reached with a starting point of 4.2 K, without pumping on the main 4He bath. The operating principle is based on the single-expansion helium liquefier: gas cooling by isothermal compression and adiabatic expansion.

  6. Development of polarized 3He ion source

    NASA Astrophysics Data System (ADS)

    Tanaka, M.; Takahashi, Y.; Shimoda, T.; Yasui, S.; Yosoi, M.; Takahisa, K.; Shimakura, N.

    2007-02-01

    A long history on the polarized 3He ion source developed at RCNP is presented. We started with an "OPPIS" (Optical Pumping Polarized Ion Source) and later found the fundamental difficulties in the OPPIS. To overcome them an "EPPIS" (Electron Pumping Polarized Ion Source) was proposed and its validity was experimentally proven. However, a serious technical disadvantage was also found in the EPPIS. To avoid this disadvantage we proposed a new concept, "SEPIS" (Spin Exchange Polarized Ion Source), which uses an enhanced spin-exchange cross section theoretically expected at low 3He+ incident energies for the 3He+ + Rb system. Next, we describe the present status of the SEPIS development; construction of a bench test device allowing the measurements of not only the spin-exchange cross sections σse but also the electron capture cross sections σec for the 3He+ + Rb system. The latest experimental data on σec are presented and compared with other previous experimental data and the theoretical calculations. A design study of the SEPIS for practical use in nuclear (cyclotron) and particle physics (synchrotron) is shortly mentioned. Finally, we mention possibility to polarize ions heavier than 3He as an application of SEPIS. The theoretical calculation showed that σse comparable to that for the 3He+ + Rb is expected for the Li2+ + Rb system, which suggests that the SEPIS will hopefully be a general tool to polarize any heavy ions.

  7. A multiple sampling ionization chamber (MUSIC) for measuring the charge of relativistic heavy ions

    NASA Astrophysics Data System (ADS)

    Christie, W. B.; Romero, J. L.; Brady, F. P.; Tull, C. E.; Castaneda, C. M.; Barasch, E. F.; Webb, M. L.; Drummond, J. R.; Crawford, H. J.; Flores, I.; Greiner, D. E.; Lindstrom, P. J.; Sann, H.; Young, J. C.

    1987-04-01

    A large area (1 m × 2 m) multiple sampling ionization chamber (MUSIC) has been constructed and tested. The MUSIC detector makes multiple measurements of energy "loss", d E/d x, for a relativistic heavy ion. Given the velocity, the charge of the ion can be extracted from the energy loss distributions. The widths of the distributions we observe are much narrower than predicted by Vavilov's theory for energy loss while agreeing well with the theory of Badhwar which deals with the energy deposited. The versatile design of MUSIC allows a variety of anode configurations which results in a large dynamic range of charge. In our tests to date we have observed charge resolutions of 0.25e fwhm for 727 MeV/nucleon40A and 0.30e fwhm for 1.08 GeV/nucleon139La and139La fragments. Vertical position and multiple track determination are obtained by using time projection chamber electronics. Preliminary tests indicate that the position resolution is also very good with α ≅ 100 μm.

  8. Photon beam quality correction factors for the NE2571A and NE2581A thimble ionization chambers using PENELOPE.

    PubMed

    Erazo, Fabián; Lallena, Antonio M

    2016-01-01

    The beam quality correction factor kQ,Q0 and the perturbation factor pQ for photon beams were calculated for the NE2571A and NE2581A ionization chambers, using the Monte Carlo simulation code PENELOPE. Results are compared to those quoted for the NE2571 and NE2581 chambers in previous works. Both kQ,Q0 and pQ obtained for NE2571A and NE2581A chambers agree with those of their predecessors NE2571 and NE2581 ones. PMID:26602965

  9. A new approach to the determination of air kerma using primary-standard cavity ionization chambers

    NASA Astrophysics Data System (ADS)

    Burns, D. T.

    2006-02-01

    A consistent formalism is presented using Monte Carlo calculations to determine the reference air kerma from the measured energy deposition in a primary-standard cavity ionization chamber. A global approach avoiding the use of cavity ionization theory is discussed and its limitations shown in relation to the use of the recommended value for W. The role of charged-particle equilibrium is outlined and the consequent requirements placed on the calculations are detailed. Values for correction factors are presented for the BIPM air-kerma standard for 60Co, making use of the Monte Carlo code PENELOPE, a detailed geometrical model of the BIPM 60Co source and event-by-event electron transport. While the wall correction factor kwall = 1.0012(2) is somewhat lower than the existing value, the axial non-uniformity correction kan = 1.0027(3) is significantly higher. The use of a point source in the evaluation of kan is discussed. A comparison is made of the calculated dose ratio with the Bragg-Gray and Spencer-Attix stopping-power ratios, the results indicating a preference for the Bragg-Gray approach in this particular case. A change to the recommended value for W of up to 2 parts in 103 is discussed. The uncertainties arising from the geometrical models, the use of phase-space files, the radiation transport algorithms and the underlying radiation interaction coefficients are estimated.

  10. Ionization chamber measurements of the half-lives of 24Na, 42K, 76As and 198Au.

    PubMed

    Unterweger, M P; Lindstrom, R M

    2004-01-01

    Samples of 24Na, 42K, 76As and 198Au were produced by irradiation in the National Institute of Standards and Technology (NIST) reactor, and examined for impurities before and after measurement. Half-life measurements were carried out in the NIST 4pigamma pressurized ionization chamber. The results are compared to presently accepted values and previous NIST measurements. PMID:14987662

  11. Perturbation correction factors for the NACP-02 plane-parallel ionization chamber in water in high-energy electron beams.

    PubMed

    Verhaegen, F; Zakikhani, R; Dusautoy, A; Palmans, H; Bostock, G; Shipley, D; Seuntjens, J

    2006-03-01

    Recent dosimetry protocols for clinical high-energy electron beams recommend measurements of absorbed dose-to-water with a plane-parallel or cylindrical ionization chamber. For well-guarded plane-parallel ionization chambers, the ionization chamber perturbation factor in water, p(Q), has a recommended value of unity in all protocols. This assumption was investigated in detail in this study for one of the recommended ionization chambers in the protocols: the Scanditronix NACP-02 plane-parallel ionization chamber. Monte Carlo (MC) simulations of the NACP-02 ionization chamber with the EGSnrc code were validated against backscatter experiments. MC simulations were then used to calculate p(wall), p(cav) and p(Q) perturbation factors and water-to-air Spencer-Attix stopping powers in 4-19 MeV electron beams of a calibration laboratory (NPL), and in 6-22 MeV clinical electron beams from a Varian CL2300 accelerator. Differences between calculated and the currently recommended (Burns et al 1996 Med. Phys. 23 383-8) stopping powers, water-to-air, were found to be limited to 0.9% at depths between the reference depth z(ref) and the depth where the dose has decreased to 50% of the maximum dose, R50. p(wall) was found to exceed unity by 2.3% in the 4 MeV NPL calibration beam at z(ref). For higher energy electron beams p(wall) decreased to a value of about 1%. Combined with a p(cav) about 1% below unity for all energies at z(ref), this was found to cause p(Q) to exceed unity significantly for all energies. In clinical electron beams all three perturbation factors were found to increase with depth. Our findings indicate that the perturbation factors have to be taken into account in calibration procedures and for clinical depth dose measurements with the NACP-02 ionization chamber. PMID:16481689

  12. Zircon 4He/3He thermochronometry

    NASA Astrophysics Data System (ADS)

    Tripathy-Lang, Alka; Fox, Matthew; Shuster, David L.

    2015-10-01

    Multiple thermochronometric methods are often required to constrain time-continuous rock exhumation for studying tectonic processes or development of km-scale topography at Earth's surface. Here, we explore 4He/3He thermochronometry of zircon as a method for constraining continuous time-temperature (t-T) paths of individual samples through a temperature range that is complementary to methods such as 40Ar/39Ar thermochronometry of K-feldspar and 4He/3He thermochronometry of apatite. For different cooling rates and diffusion domain size, the temperature sensitivity of zircon 4He/3He thermochronometry ranges from slightly less than 100 °C to slightly greater than 250 °C; a typical sample provides continuous thermal constraints over ∼100 °C within that range. Outside these temperatures, 4He in zircon will either be quantitatively retained or completely lost by volume diffusion. As proof-of-concept, we present stepwise release 4He/3He spectra and associated U and Th concentration maps measured by laser ablation ICP-MS analysis of individual crystal aliquots of Fish Canyon Tuff (FCT) zircon and of a more complex setting in the Sierra Nevada batholith that experienced reheating from a proximal basaltic intrusion, the Little Devil's Postpile (LDP). The FCT zircon 4He/3He release spectra are consistent with a 4He spatial distribution dominated by alpha-ejection from crystal surfaces. The spatial distributions of U and Th measured in the same crystals do not substantially influence 4He/3He release spectra that are predicted for the known thermal history, even when incorporating spatially variable diffusivity due to accumulation of radiation damage. Conversely, the LDP 4He/3He release spectra are strongly influenced by the observed parent nuclide zonation. A three-dimensional (3D) numerical model of 4He production and diffusion, which incorporates crystal geometry, U and Th zonation, and spatially variable He diffusion kinetics, substantially improves the fit between

  13. Dislocation motion in solid hcp 3He

    NASA Astrophysics Data System (ADS)

    Beamish, John; Cheng, Zhi Gang

    At temperatures above about 100 mK, dislocations reduce the shear modulus of hcp 4He by as much as 90 %. This occurs when dislocations thermally unbind from the 3He impurities that pin them, becoming extraordinarily mobile. The elastic softening is accompanied by a thermally activated dissipation peak due to the 3He impurities. At higher temperatures the dissipation has an ωT4 dependence caused by scattering of thermal phonons from moving dislocations. Previous measurements on the fermi solid, hcp 3He, showed a similar dislocation softening, but the corresponding dissipation was not measured. We have extended these measurements by measuring the temperature, amplitude and frequency dependence of both the shear modulus and the dissipation in hcp 3He. The dissipation behavior is very different from that of hcp 4He. Neither the impurity unbinding peak associated with the elastic softening, nor the high temperature phonon scattering dissipation, were observed. Instead, there is a large and non-thermally activated dissipation which is largest at low frequencies. We believe that this unexpected dissipation is associated with a new dislocation damping mechanism in 3He, perhaps associated with spin rearrangements caused by moving dislocations. This work was supported by a grant from NSERC Canada.

  14. Polarization of3He and3He-4He mixtures with the castaing-nozieres method

    NASA Astrophysics Data System (ADS)

    van Woerkens, C. M. C. M.; Remeijer, P.; Steel, S. C.; Jochemsen, R.; Frossati, G.

    1996-01-01

    We describe experiments employing a strongly improved technique to prepare highly polarized3He and3He-4He mixtures. The polarization is obtained with the rapid melting method. A novel design cell using Vespel SP-1 (a sintered form of polyimide) can reach relative volume changes of 17%, which is required to decompress a completely solid3He-4He mixture to a completely liquid state at 23 bar.

  15. Design of an Ion Source for {sup 3}He Fusion in a Low Pressure IEC Device

    SciTech Connect

    Piefer, Gregory R.; Santarius, John F.; Ashley, Robert P.; Kulcinski, Gerald L.

    2005-05-15

    Recent developments in helicon ion sources and Inertial Electrostatic Confinement (IEC) device performance at UW-Madison have enabled low pressure (< 50 {mu}torr, 6.7 mPa) operating conditions that should allow the {sup 3}He-{sup 3}He fusion reaction to be observed in an IEC device. An ion source capable of delivering a {approx} 10 mA {sup 3}He ion beam into an IEC device with minimal neutral gas flow has been designed and tested. Furthermore, a new IEC device that has never been operated with deuterium has been constructed to avoid D-{sup 3}He protons from obstructing the {sup 3}He-{sup 3}He reaction product spectrum, and to minimize Penning ionization of deuterium by excited helium, which in the past is suspected to have limited the ionized density of He. These developments make it possible to study beam-background {sup 3}He-{sup 3}He fusion reactions with > 300 mA recirculating ion currents.

  16. Coherent Photoproduction of pi^+ from 3/^He

    SciTech Connect

    Rakhsha Nasseripour, Barry Berman

    2011-03-01

    We have measured the differential cross section for the $\\gamma$$^3$He$\\rightarrow \\pi^+ t$ reaction. This reaction was studied using the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab. Real photons produced with the Hall-B bremsstrahlung tagging system in the energy range from 0.50 to 1.55 GeV were incident on a cryogenic liquid $^3$He target. The differential cross sections for the $\\gamma$$^3$He$\\rightarrow \\pi^+ t$ reaction were measured as a function of photon-beam energy and pion-scattering angle. Theoretical predictions to date cannot explain the large cross sections except at backward angles, showing that additional components must be added to the model.

  17. Photoproduction of eta-mesic 3He.

    PubMed

    Pfeiffer, M; Ahrens, J; Annand, J R M; Beck, R; Caselotti, G; Cherepnya, S; Föhl, K; Fog, L S; Hornidge, D; Janssen, S; Kashevarov, V; Kondratiev, R; Kotulla, M; Krusche, B; McGeorge, J C; MacGregor, I J D; Mengel, K; Messchendorp, J G; Metag, V; Novotny, R; Rost, M; Sack, S; Sanderson, R; Schadmand, S; Thomas, A; Watts, D P

    2004-06-25

    The photoproduction of eta-mesic 3He has been investigated using the TAPS calorimeter at the Mainz Microtron accelerator facility MAMI. The total inclusive cross section for the reaction gamma3He-->etaX has been measured for photon energies from threshold to 820 MeV. The total and angular differential coherent eta cross sections have been extracted up to energies of 745 MeV. A resonancelike structure just above the eta production threshold with an isotropic angular distribution suggests the existence of a resonant quasibound state. This is supported by studies of a competing decay channel of such a quasibound eta-mesic nucleus into pi(0)pX. A binding energy of (-4.4+/-4.2) MeV and a width of (25.6+/-6.1) MeV is deduced for the quasibound eta-mesic state in 3He. PMID:15244998

  18. Hyperfine structure of /sup 3/He

    SciTech Connect

    Druzbick, J.; Williams, H.T.

    1987-01-01

    Relativistic contribution to the hyperfine structure of /sup 3/He are reexamined in order to resolve inconsistencies in published values. The orbit-orbit and diamagnetic screening contributions are recomputed and are found to contribute less than one part per million (ppm), contrary to previous results. A new value (318 ppm compared to the perturbation result of 327 ppm) is obtained for the relativistic velocity correction using recently available relativistic Hartree-Fock wave functions. New values of the hyperfine-structure splitting of /sup 3/He in the 1S2S state and the /sup 3/He ion in the 1S and 2S states are presented. Comparison with experiment suggests that the relativistic velocity correction should be 323 ppm and the nuclear structure correction should be 184.2 ppm.

  19. Nuclear electric dipole moment of 3He

    SciTech Connect

    Stetcu, Ionel; Friar, J L; Hayes, A C; Liu, C P; Navratil, P

    2008-01-01

    In the no-core shell model (NCSM) framework, we calculate the {sup 3}He electric dipole moment (EDM) generated by parity- and time-reversal violation in the nucleon-nucleon interaction. While the results are somehow sensitive to the interaction model chosen for the strong two- and three-body interactions, we demonstrate the pion-exchange dominance to the EDM of {sup 3}He, if the coupling constants for {pi}, {rho} and {omega}-exchanges are of comparable magnitude, as expected. Finally, our results suggest that a measurement of {sup 3}He EDM would be complementary to the currently planned neutron and deuteron experiments, and would constitute a powerful constraint to the models of the pion P- and T-violating interactions.

  20. Time-resolved dosimetry using a pinpoint ionization chamber as quality assurance for IMRT and VMAT

    SciTech Connect

    Louwe, Robert J. W. Satherley, Thomas; Day, Rebecca A.; Greig, Lynne; Wendling, Markus; Monshouwer, René

    2015-04-15

    Purpose: To develop a method to verify the dose delivery in relation to the individual control points of intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) using an ionization chamber. In addition to more effective problem solving during patient-specific quality assurance (QA), the aim is to eventually map out the limitations in the treatment chain and enable a targeted improvement of the treatment technique in an efficient way. Methods: Pretreatment verification was carried out for 255 treatment plans that included a broad range of treatment indications in two departments using the equipment of different vendors. In-house developed software was used to enable calculation of the dose delivery for the individual beamlets in the treatment planning system (TPS), for data acquisition, and for analysis of the data. The observed deviations were related to various delivery and measurement parameters such as gantry angle, field size, and the position of the detector with respect to the field edge to distinguish between error sources. Results: The average deviation of the integral fraction dose during pretreatment verification of the planning target volume dose was −2.1% ± 2.2% (1 SD), −1.7% ± 1.7% (1 SD), and 0.0% ± 1.3% (1 SD) for IMRT at the Radboud University Medical Center (RUMC), VMAT (RUMC), and VMAT at the Wellington Blood and Cancer Centre, respectively. Verification of the dose to organs at risk gave very similar results but was generally subject to a larger measurement uncertainty due to the position of the detector at a high dose gradient. The observed deviations could be related to limitations of the TPS beam models, attenuation of the treatment couch, as well as measurement errors. The apparent systematic error of about −2% in the average deviation of the integral fraction dose in the RUMC results could be explained by the limitations of the TPS beam model in the calculation of the beam penumbra. Conclusions: This

  1. Neutron polarizers based on polarized ^3He

    NASA Astrophysics Data System (ADS)

    Gentile, T. R.; Jones, G. L.; Thompson, A. K.; Fei, X.; Keith, C. D.; Rich, D.; Snow, W. M.; Penttila, S.

    1997-10-01

    Research is underway at NIST, Indiana Univ., and LANL to develop neutron polarizers and analyzers based on polarized ^3He. Such devices, which rely on the strong spin dependence of the neutron capture cross section by polarized ^3He, have applications in weak interaction physics and materials science. In addition, the technology for polarized ^3He production is directly applicable to polarized gas MRI of lungs, and polarized targets. Our program, which includes both the spin-exchange and metastability-exchange optical pumping methods, will be reviewed. Spin-exchange has been used to analyze a polarized cold neutron beam at NIST, and also for lung imaging in collaboration with the Univ. of Pennsylvania. In the metastable method, the ^3He is polarized at low pressure, and must be substantially compressed. A piston compressor has been designed for this goal at Indiana Univ. and is under construction. At NIST we have compressed polarized gas using an apparatus that is based on a modified commercial diaphragm pump.

  2. Applications of {sup 3}He neutron detectors

    SciTech Connect

    Testov, D. A.; Briancon, Ch.; Dmitriev, S. N.; Yeremin, A. V.; Penionzhkevich, Yu. E.; Pyatkov, Yu. V.; Sokol, E. A.

    2009-01-15

    Neutron detectors with {sup 3}He-filled proportional counters are described. The use of these detectors in measuring the probability of neutron emission (in particular, multiparticle neutron emission) after the {beta} decay of neutron-rich nuclei and in studying rare events of spontaneous fission of superheavy nuclei is considered.

  3. Assaying of targets for nuclear measurements with a gridded ionization chamber

    NASA Astrophysics Data System (ADS)

    Budtz-Jørgensen, C.; Knitter, H. H.; Bortels, G.

    1985-06-01

    An ionization chamber with a Frisch grid is used to determine both the energy ( E) of the charge particles emitted from the sample positioned coplanar with the cathode, and the cosine of the emission angle (ϑ) with respect to the normal of the cathode Using the combined information on cosϑ and E, problems in particle counting due to sample absoprtion and scattering effect can be circumvented and sample source strengths are readily determined to an accurary of 0.3%. However, it is emphasized that the source strength can be determined from the particles emitted in a large solid angle close to 2τ sr, which means a considerable higher efficiency than for the conventional low geometry counting techniques. Moreover the present method, within reasonable limits is insensitive to source shape and thickness homogeneity. The technique will be illustrated by measurements of alpha particles and fission fragments emitted from a set of four vacuum evaporated UF 4, three electrodeposited and one suspension-sprayed 235U 3O 8 layers. The energy and angular distributions of alpha particles and of the heavy alpha recoils emitted from a self transferred 224Ra source will be discussed. The low energetic alpha recoils might be useful as probes for the investigation of ultrathin ( < 400 Å) layers.

  4. Detecting MLC errors in stereotactic radiotherapy plans with a liquid filled ionization chamber array.

    PubMed

    O'Connor, Patrick; Seshadri, Venkatakrisnan; Charles, Paul

    2016-03-01

    Quality assurance of stereotactic radiotherapy demands the use of equipment with the highest resolution and sensitivity available. This study examines the sensitivity of a commercially available liquid-filled ionization chamber array-the Octavius 1000 SRS (PTW, Frieburg, Germany) for detecting small (sub-millimetre) multi-leaf collimator (MLC) alignment errors in static square fields (side length 16-40 mm). Furthermore, the effectiveness of detecting small MLC errors in clinical stereotactic radiotherapy patient plans using the device was also evaluated. The commonly used gamma pass rate metric (of the measurements compared with treatment planning system generated results) was used. The gamma pass rates were then evaluated as a function of MLC position error (MLC error size 0.1-2.5 mm). The detector array exhibited a drop in pass rate between plans without error and those which had MLC errors induced. For example a drop in pass rate of 4.5 % (gamma criteria 3 %, 1 mm) was observed when a 0.8 mm error was introduced into a 16 mm square field. Furthermore the drop in pass rate increased as the MLC position error increased. This study showed that the Octavius 1000 SRS array could be a useful tool for applications requiring the detection of small geometric delivery uncertainties. PMID:26979835

  5. The control system of the multi-strip ionization chamber for the HIMM

    NASA Astrophysics Data System (ADS)

    Li, Min; Yuan, Y. J.; Mao, R. S.; Xu, Z. G.; Li, Peng; Zhao, T. C.; Zhao, Z. L.; Zhang, Nong

    2015-03-01

    Heavy Ion Medical Machine (HIMM) is a carbon ion cancer treatment facility which is being built by the Institute of Modern Physics (IMP) in China. In this facility, transverse profile and intensity of the beam at the treatment terminals will be measured by the multi-strip ionization chamber. In order to fulfill the requirement of the beam position feedback to accomplish the beam automatic commissioning, less than 1 ms reaction time of the Data Acquisition (DAQ) of this detector must be achieved. Therefore, the control system and software framework for DAQ have been redesigned and developed with National Instruments Compact Reconfigurable Input/Output (CompactRIO) instead of PXI 6133. The software is Labview-based and developed following the producer-consumer pattern with message mechanism and queue technology. The newly designed control system has been tested with carbon beam at the Heavy Ion Research Facility at Lanzhou-Cooler Storage Ring (HIRFL-CSR) and it has provided one single beam profile measurement in less than 1 ms with 1 mm beam position resolution. The fast reaction time and high precision data processing during the beam test have verified the usability and maintainability of the software framework. Furthermore, such software architecture is easy-fitting to applications with different detectors such as wire scanner detector.

  6. Proton beam dosimetry: a comparison between the Faraday cup and an ionization chamber.

    PubMed

    Cambria, R; Hérault, J; Brassart, N; Silari, M; Chauvel, P

    1997-06-01

    From the theoretical point of view, the Faraday cup (FC) is an absolute instrument for fluence measurements of proton beams. As the FC is easily manufactured it can be considered an 'in-house' calibration system. Moreover, at the moment no national standards for proton dosimetry are available. Up to now the experimental tests of these instruments show that much study still has to be done to better understand their use in reference dosimetry. To investigate the possibility of using an FC as a secondary standard, an FC was jointly designed by the 'TERA Collaboration' and 'Centre Antoine-Lacassagne' (Nice, France) to evaluate the main parameters of the instrument. A comparison between two FCs of different designs--the 'TERA FC' and the 'Nice FC'--and an ionization chamber (IC) used for routine proton dosimetry was carried out. Results show that the two FCs agree to within 1.5-3.6%. While the differences between FC and IC are larger--6% for the 'TERA FC' and 8.2% for the 'Nice FC', the FC giving a lower dose evaluation--they follow the same trend shown by the calorimetric measurements. The data show that once the beam characteristics are defined, the fluence measurements are reproducible and show a good accuracy. PMID:9194137

  7. A patient-specific quality assurance study on absolute dose verification using ionization chambers of different volumes in RapidArc treatments

    SciTech Connect

    Syam Kumar, S.A.; Sukumar, Prabakar; Sriram, Padmanaban; Rajasekaran, Dhanabalan; Aketi, Srinu; Vivekanandan, Nagarajan

    2012-01-01

    The recalculation of 1 fraction from a patient treatment plan on a phantom and subsequent measurements have become the norms for measurement-based verification, which combines the quality assurance recommendations that deal with the treatment planning system and the beam delivery system. This type of evaluation has prompted attention to measurement equipment and techniques. Ionization chambers are considered the gold standard because of their precision, availability, and relative ease of use. This study evaluates and compares 5 different ionization chambers: phantom combinations for verification in routine patient-specific quality assurance of RapidArc treatments. Fifteen different RapidArc plans conforming to the clinical standards were selected for the study. Verification plans were then created for each treatment plan with different chamber-phantom combinations scanned by computed tomography. This includes Medtec intensity modulated radiation therapy (IMRT) phantom with micro-ionization chamber (0.007 cm{sup 3}) and pinpoint chamber (0.015 cm{sup 3}), PTW-Octavius phantom with semiflex chamber (0.125 cm{sup 3}) and 2D array (0.125 cm{sup 3}), and indigenously made Circular wax phantom with 0.6 cm{sup 3} chamber. The measured isocenter absolute dose was compared with the treatment planning system (TPS) plan. The micro-ionization chamber shows more deviations when compared with semiflex and 0.6 cm{sup 3} with a maximum variation of -4.76%, -1.49%, and 2.23% for micro-ionization, semiflex, and farmer chambers, respectively. The positive variations indicate that the chamber with larger volume overestimates. Farmer chamber shows higher deviation when compared with 0.125 cm{sup 3}. In general the deviation was found to be <1% with the semiflex and farmer chambers. A maximum variation of 2% was observed for the 0.007 cm{sup 3} ionization chamber, except in a few cases. Pinpoint chamber underestimates the calculated isocenter dose by a maximum of 4.8%. Absolute dose

  8. Neutron Polarizers Based on Polarized 3He

    SciTech Connect

    William M. Snow

    2005-05-01

    The goal of this work, which is a collaborative effort between Indiana University, NIST, and Hamilton College, is to extend the technique of polarized neutron scattering into new domains by the development and application of polarized 3He-based neutron spin filters. After the IPNS experiment which measured Zeeman sp[litting in surface scattered neutrons using a polarized 3He cell as a polarization analyzer transporterd by car from Bloomington to Chicago, the Indiana work focused on technical developments to improve the 3He polarization of the Indiana compression system. The compression system was rebuilt with a new valve system which allows gas trapped in the dead volume of the compressors at the end of the piston stroke to be exhausted and conducted back to the optical pumping cell where it can be repolarized. We also incorporated a new intermediate storage volume made at NIST from 1720 glass which will reduce polarization losses between the compressors. Furthermore, we improved the stability of the 1083 nm laser by cooling the LMA rod. We achieved 60% 3he polarization in the optical pumping cell and 87% preservation of the polarization during compression. In parallel we built a magnetically-shielded transport solenoid for use on neutron scattering instruments such as POSY which achieves a fractional field uniformity of better than 10-3 per cm. The field was mapped using an automated 3D field mapping system for in-situ measurement of magnetic field gradients Diluted magnetic semiconductors offer many exciting opportunities for investigation of spintronic effects in solids and are certain to be one of the most active areas of condensed matter physics over then next several years. These materials can act as efficient spin injectors for devices that make use of spin-dependent transport phenomena. We just (late July 2002) finished a neutron reflectivity experiment at NIST on a GaMnAs trilayer film. This material is a ferromagnetic semiconductor which is of interest

  9. 3He Spin Filter for Neutrons

    PubMed Central

    Batz, M.; Baeßler, S.; Heil, W.; Otten, E. W.; Rudersdorf, D.; Schmiedeskamp, J.; Sobolev, Y.; Wolf, M.

    2005-01-01

    The strongly spin-dependent absorption of neutrons in nuclear spin-polarized 3He opens up the possibility of polarizing neutrons from reactors and spallation sources over the full kinematical range of cold, thermal and hot neutrons. This paper gives a report on the neutron spin filter (NSF) development program at Mainz. The polarization technique is based on direct optical pumping of metastable 3He atoms combined with a polarization preserving mechanical compression of the gas up to a pressure of several bar, necessary to run a NSF. The concept of a remote type of operation using detachable NSF cells is presented which requires long nuclear spin relaxation times of order 100 hours. A short survey of their use under experimental conditions, e.g. large solid-angle polarization analysis, is given. In neutron particle physics NSFs are used in precision measurements to test fundamental symmetry concepts. PMID:27308139

  10. Surface tension maximum of liquid 3He

    NASA Astrophysics Data System (ADS)

    Matsumoto, Koichi; Hasegawa, Syuichi; Suzuki, Masaru; Okuda, Yuichi

    2000-07-01

    The surface tension of liquid 3He was measured using the capillary-rise method. Suzuki et al. have reported that its temperature dependence was almost quenched below 120 mK. Here we have examined it with higher precision and found that it has a small maximum around 100 mK. The amount of the maximum is about 3×10 -4 as a fraction of the surface tension at 0 K. The density of liquid 3He increases with temperature by about 5×10 -4 in Δ ρ/ ρ between 0 and 100 mK. This density change could be one of the reasons of the surface tension maximum around 100 mK.

  11. First detection of 3He+ in the planetary nebula IC 418

    NASA Astrophysics Data System (ADS)

    Guzman-Ramirez, L.; Rizzo, J. R.; Zijlstra, A. A.; García-Miró, C.; Morisset, C.; Gray, M. D.

    2016-07-01

    The 3He isotope is important to many fields of astrophysics, including stellar evolution, chemical evolution, and cosmology. The isotope is produced in low-mass stars which evolve through the planetary nebula (PN) phase. 3He abundances in PNe can help test models of the chemical evolution of the Galaxy. We present the detection of the 3He+ emission line using the single dish Deep Space Station 63, towards the PN IC 418. We derived a 3He/H abundance in the range 1.74 ± 0.8 × 10-3 to 5.8 ± 1.7 × 10-3, depending on whether part of the line arises in an outer ionized halo. The lower value for 3He/H ratio approaches values predicted by stellar models which include thermohaline mixing, but requires that large amounts of 3He are produced inside low-mass stars which enrich the interstellar medium (ISM). However, this overpredicts the 3He abundance in H II regions, the ISM, and protosolar grains, which is known to be of the order of 10-5. This discrepancy questions our understanding of the evolution of the 3He, from circumstellar environments to the ISM.

  12. First Detection of 3He+ in the Planetary Nebula IC 418

    NASA Astrophysics Data System (ADS)

    Guzman-Ramirez, L.; Rizzo, J. R.; Zijlstra, A. A.; García-Miró, C.; Morisset, C.; Gray, M. D.

    2016-04-01

    The 3He isotope is important to many fields of astrophysics, including stellar evolution, chemical evolution, and cosmology. The isotope is produced in low-mass stars which evolve through the planetary nebula (PN) phase. 3He abundances in PNe can help test models of the chemical evolution of the Galaxy. We present the detection of the 3He+ emission line using the single dish Deep Space Station 63, towards the PN IC 418. We derived a 3He/H abundance in the range 1.74±0.8×10-3 to 5.8±1.7×10-3, depending on whether part of the line arises in an outer ionized halo. The lower value for 3He/H ratio approaches values predicted by stellar models which include thermohaline mixing, but requires that large amounts of 3He are produced inside low-mass stars which enrich the interstellar medium (ISM). However, this over-predicts the 3He abundance in H II regions, the ISM, and proto-solar grains, which is known to be of the order of 10-5. This discrepancy questions our understanding of the evolution of the 3He, from circumstellar environments to the ISM.

  13. A standard Fricke dosimeter compared to an ionization chamber used for dosimetric characterization of 60Co photon beam

    NASA Astrophysics Data System (ADS)

    Moussous, Ouiza; Medjadj, Toufik

    2016-06-01

    The main objective of this study was to investigate the Fricke dosimeter water equivalent system for measurement of dosimetric parameters for photon beam. The parameters measured with the Fricke dosimeter were compared to those obtained with an ionization chamber. In this work characteristics for 60Co γ-rays of field sizes ranging from 5 × 5 cm2 to 20 × 20 cm2 are reported. The measurements were carried out in the secondary standard dosimetry laboratory using a collimated 60Co gamma source therapy unit. The 60Co beam output in terms of absorbed dose to water was obtained as per IAEA TRS 398 recommendations using cylindrical ionization chamber, whose ND,w has been supplied by the IAEA's reference laboratory. Specific quantities measured include: output factors, peak scatter factor, lateral beam profiles and percentage depth dose. The Fricke dosimeters were irradiated in a water phantom using the suitable poly (methyl methacrylate), PMMA stand. Our results demonstrate that Fricke dosimeter and ionization chamber agree with each other.

  14. The effect of low-energy electrons on the response of ion chambers to ionizing photon beams

    NASA Astrophysics Data System (ADS)

    La Russa, Daniel J.

    Cavity ionization chambers are one of the most popular and widely used devices for quantifying ionizing photon beams. This popularity originates from the precision of these devices and the relative ease with which ionization measurements are converted to quantities of interest in therapeutic radiology or radiation protection, collectively referred to as radiation dosimetry. The formalisms used for these conversions, known as cavity theory, make several assumptions about the electron spectrum in the low-energy range resulting from the incident photon beam. These electrons often account for a significant fraction of the ion chamber response. An inadequate treatment of low-energy electrons can therefore significantly effect calculated quantities of interest. This thesis sets out to investigate the effect of low-energy electrons on (1) the use of Spencer-Attix cavity theory with 60Co beams; and (2) the standard temperature-pressure correction factor, P TP, used to relate the measured ionization to a set of reference temperature and pressure conditions for vented ion chambers. Problems with the PTP correction are shown to arise when used with kilovoltage x rays, where ionization measurements are due primarily to electrons that do not have enough energy to cross the cavity. A combination of measurements and Monte Carlo calculations using the EGSnrc Monte Carlo code demonstrate the breakdown of PTP in these situations when used with non-air-equivalent chambers. The extent of the breakdown is shown to depend on cavity size, energy of the incident photons, and the composition of the chamber. In the worst case, the standard P TP factor overcorrects the response of an aluminum chamber by ≈12% at an air density typical of Mexico City. The response of a more common graphite-walled chamber with similar dimensions at the same air density is undercorrected by ≈ 2%. The EGSnrc Monte Carlo code is also used to investigate Spencer-Attix cavity theory as it is used in the

  15. Use of a novel two-dimensional ionization chamber array for pencil beam scanning proton therapy beam quality assurance.

    PubMed

    Lin, Liyong; Kang, Minglei; Solberg, Timothy D; Mertens, Thierry; Baeumer, Christian; Ainsley, Christopher G; McDonough, James E

    2015-01-01

    The need to accurately and efficiently verify both output and dose profiles creates significant challenges in quality assurance of pencil beam scanning (PBS) proton delivery. A system for PBS QA has been developed that combines a new two-dimensional ionization chamber array in a waterproof housing that is scanned in a water phantom. The MatriXX PT has the same detector array arrangement as the standard MatriXX(Evolution) but utilizes a smaller 2 mm plate spacing instead of 5mm. Because the bias voltage of the MatriXX PT and Evolution cannot be changed, PPC40 and FC65-G ionization chambers were used to assess recombination effects. The PPC40 is a parallel plate chamber with an electrode spacing of 2mm, while the FC65-G is a Farmer chamber FC65-G with an electrode spacing of 2.8 mm. Three bias voltages (500, 200, and 100 V) were used for both detectors to determine which radiation type (continuous, pulse or pulse-scanned beam) could closely estimate Pion from the ratios of charges collected. In comparison with the MatriXX(Evolution), a significant improvement in measurement of absolute dose with the MatriXX PT was observed. While dose uncertainty of the MatriXX(Evolution) can be up to 4%, it is < 1% for the MatriXX PT. Therefore the MatriXX(Evolution) should not be used for QA of PBS for conditions in which ion recombination is not negligible. Farmer chambers should be used with caution for measuring the absolute dose of PBS beams, as the uncertainty of Pion can be > 1%; chambers with an electrode spacing of 2 mm or smaller are recommended. PMID:26103492

  16. Coupling between Solid 3He on Aerogel and Superfluid 3He in the Low Temperature Limit

    SciTech Connect

    Bradley, D. I.; Fisher, S. N.; Guenault, A. M.; Haley, R. P.; Pickett, G. R.; Tsepelin, V.; Whitehead, R. C. V.; Skyba, P.

    2006-09-07

    We have cooled liquid 3He contained in a 98% open aerogel sample surrounded by bulk superfluid 3He-B at zero pressure to below 120 {mu}K. The aerogel sample is placed in a quasiparticle blackbody radiator cooled by a Lancaster-style nuclear cooling stage to {approx}200 {mu}K. We monitor the temperature of the 3He inside the blackbody radiator using a vibrating wire resonator. We find that reducing the magnetic field on the aerogel sample causes substantial cooling of all the superfluid inside the blackbody radiator. We believe this is due to the demagnetization of the solid 3He layers on the aerogel strands. This system has potential for achieving extremely low temperatures in the confined fluid.

  17. SU-E-T-415: An Ionization Chamber Array with High Spatial Resolution for External Beam Radiotherapy

    SciTech Connect

    Togno, M; Wilkens, J; Menichelli, D

    2014-06-01

    Purpose: To characterize an ionization chamber array technology with high spatial resolution and high charge collection efficiency for external beam radiotherapy. Methods: The prototype under test is a linear array of air vented ionization chambers developed by IBA Dosimetry, consisting of 80 pixels with 3.5mm spatial resolution and 4mm{sup 3} sensitive volume. The detector was characterized in a plastic phantom with {sup 60} Co radiation and MV X-rays from an ELEKTA Agility LINAC (with flattened and unflattened beam qualities). Bias voltage was varied in order to evaluate charge collection efficiency. A commercial array of ionization chambers (MatriXX Evolution, IBA Dosimetry) and an amorphous silicon flat panel in direct conversion configuration were used as references. Results: Repeatability (0.4%) and stability under continuous gamma irradiation (0.3%) are very good, in spite of low active volume and sensitivity (∼200pC/Gy). Charge collection efficiency is higher than 99% already at 150V with ∼2mGy dose per pulse, leading to a ±1.1% sensitivity change with dose per pulse in the range 0.09-2mGy (covering all flattened and unflattened applications). Measured dose profiles are in agreement with MatriXX for fields larger than 2×2cm{sup 2}, in which case the linear array offers a much better characterization of the penumbra region. Down to 1×1cm{sup 2}, measured profiles are in very good agreement with the flat panel. Conclusion: The array represents a valuable tool for the characterization of treatment fields in which high spatial resolution is required, together with the dosimetric performance of air vented ionization chambers. Such a technology would be particularly valuable in association with advanced treatment modalities such as rotational radiotherapy, stereotactic treatments (even with unflattened beam qualities) and proton therapy, due to the insensitivity of the chambers on dose per pulse. In the future, a two dimensional prototype based on this

  18. Nuclear Electric Dipole Moment of 3He

    SciTech Connect

    Stetcu, I; P.Liu, C; Friar, J L; Hayes, A C; Navratil, P

    2008-04-08

    A permanent electric dipole moment (EDM) of a physical system would require time-reversal (T) violation, which is equivalent to charge-conjugation-parity (CP) violation by CPT invariance. Experimental programs are currently pushing the limits on EDMs in atoms, nuclei, and the neutron to regimes of fundamental theoretical interest. Nuclear EDMs can be studied at ion storage rings with sensitivities that may be competitive with atomic and neutron measurements. Here we calculate the magnitude of the CP-violating EDM of {sup 3}He and the expected sensitivity of such a measurement to the underlying CP-violating interactions. Assuming that the coupling constants are of comparable magnitude for {pi}-, {rho}-, and {omega}-exchanges, we find that the pion-exchange contribution dominates. Finally, our results suggest that a measurement of the {sup 3}He EDM is complementary to the planned neutron and deuteron experiments, and could provide a powerful constraint for the theoretical models of the pion-nucleon P,T-violating interaction.

  19. Nuclear Electric Dipole Moment of ^{3}_He

    SciTech Connect

    Stetcu, I.; Liu, C.-P.; Friar, J. L.; Hayes, A. C.; Navratil, P.

    2008-01-01

    A permanent electric dipole moment (EDM) of a physical system would require time-reversal (T) violation, which is equivalent to charge-conjugation-parity (CP) violation by CPT invariance. Experimental programs are currently pushing the limits on EDMs in atoms, nuclei, and the neutron to regimes of fundamental theoretical interest. Nuclear EDMs can be studied at ion storage rings with sensitivities that may be competitive with atomic and neutron measurements. Here we calculate the magnitude of the CP-violating EDM of ^{3}_He and the expected sensitivity of such a measurement to the underlyng CP-violating interactions. Assuming that the coupling constants are of comparable magnitude for {\\pi}-, {\\rho}-, and {\\omega}-exchanges, we find that the pion-exchange contribution dominates. Our results suggest that a measurement of the ^{3}_He EDM is complementary to the planned neutron and deuteron experiments, and could provide a powerful constraint for the theoretical models of the pion-nucleon P,T-violating interaction.

  20. A Liquid Xenon Ionization Chamber in an All-fluoropolymer Vessel

    SciTech Connect

    LePort, F.; Pocar, A.; Bartoszek, L.; DeVoe, R.; Fierlinger, P.; Flatt, B.; Gratta, G.; Green, M.; Montero Diez, M.; Neilson, R.; O'Sullivan, K.; Wodin, J.; Woisard, D.; Baussan, E.; Breidenbach, M.; Conley, R.; Fairbank, W., Jr.; Farine, J.; Hall, K.; Hallman, D.; Hargrove, C.; /Stanford U., Phys. Dept. /Applied Plastics Technology, Bristol /Neuchatel U. /SLAC /Colorado State U. /Laurentian U. /Carleton U. /Alabama U. /Moscow, ITEP

    2007-02-26

    A novel technique has been developed to build vessels for liquid xenon ionization detectors entirely out of ultra-clean fluoropolymer. We describe the advantages in terms of low radioactivity contamination, provide some details of the construction techniques, and show the energy resolution achieved with a prototype all-fluoropolymer ionization detector.

  1. Formation of 3He droplets in dilute 3He-4He solid solutions

    NASA Astrophysics Data System (ADS)

    Huan, Chao; Candela, Don; Kim, Sung; Yin, Liang; Xia, Jiang-Sheng; Sullivan, Neil

    2015-03-01

    We review the different stages of the formation of 3He droplets in dilute solid 3He-4He solutions. The studies are interesting because the phase separation in isotopic helium mixtures is a first-order transition with a conserved order parameter. The rate of growth of the droplets as observed in NMR studies is compared with the rates expected for homogeneous nucleation followed by a period of coarsening known as Ostwald ripening. Work suported by the National Science Foundation - DMR-1303599 and DMR- 1157490 (National High Magnetic Field Laboratory).

  2. {sup 3}He melting pressure thermometry

    SciTech Connect

    Ni, W.; Xia, J.S.; Adams, E.D.

    1995-10-01

    High-precision measurements of the {sup 3}He melting pressure versus temperature have been made from 500 {mu}K to 25 mK using a {sup 60}Co nuclear orientation primary thermometer and a Pt NMR susceptibility secondary thermometer. Temperatures for the fixed points on the melting curve are: the superfluid A transition T{sub A}=2.505 mK, the A-B transition T{sub AB}=1.948 mK, and the solid ordering temperature T{sub N}=0.934 mK. These fixed points and a functional form for P(T) constitute a convenient temperature scale, based on a primary thermometer, usable to well below 1 mK.

  3. Dosimetric Verification and Validation of Conformal and IMRT Treatments Fields with an Ionization Chamber 2D-Array

    NASA Astrophysics Data System (ADS)

    Evangelina, Figueroa M.; Gabriel, Reséndiz G.; Miguel, Pérez P.

    2008-08-01

    A three-dimensional treatment planning system requires comparisons of calculated and measured dose distributions. It is necessary to confirm by means of patient specific QA that the dose distributions are correctly calculated, and that the patient data is correctly transferred to and delivered by the treatment machine. We used an analysis software for bi-dimensional dosimetric verification of conformal treatment and IMRT fields using as objective criterion the gamma index. An ionization chamber bi-dimensional array was used for absolute dose measurement in the complete field area.

  4. Correction factors for ionization chamber dosimetry in CyberKnife: Machine-specific, plan-class, and clinical fields

    SciTech Connect

    Gago-Arias, Araceli; Antolin, Elena; Fayos-Ferrer, Francisco; Simon, Rocio; Gonzalez-Castano, Diego M.; Palmans, Hugo; Sharpe, Peter; Gomez, Faustino; Pardo-Montero, Juan

    2013-01-15

    Purpose: The aim of this work is the application of the formalism for ionization chamber reference dosimetry of small and nonstandard fields [R. Alfonso, P. Andreo, R. Capote, M. S. Huq, W. Kilby, P. Kjaell, T. R. Mackie, H. Palmans, K. Rosser, J. Seuntjens, W. Ullrich, and S. Vatnitsky, 'A new formalism for reference dosimetry of small and nonstandard fields,' Med. Phys. 35, 5179-5186 (2008)] to the CyberKnife robotic radiosurgery system. Correction factors for intermediate calibration fields, a machine-specific reference field (msr) and two plan-class specific reference fields (pcsr), have been studied. Furthermore, the applicability of the new formalism to clinical dosimetry has been analyzed through the investigation of two clinical treatments. Methods: PTW31014 and Scanditronix-Wellhofer CC13 ionization chamber measurements were performed for the fields under investigation. Absorbed dose to water was determined using alanine reference dosimetry, and experimental correction factors were calculated from alanine to ionization chamber readings ratios. In addition, correction factors were calculated for the intermediate calibration fields and one of the clinical treatment fields using the Monte Carlo method and these were compared with the experimental values. Results: Overall correction factors deviating from unity by approximately 2% were obtained from both measurements and simulations, with values below and above unity for the studied intermediate calibration fields and clinical fields for the ionization chambers under consideration. Monte Carlo simulations yielded correction factors comparable with those obtained from measurements for the machine-specific reference field, although differences from 1% to 3.3% were observed between measured and calculated correction factors for the composite intermediate calibration fields. Dose distribution inhomogeneities are thought to be responsible for such discrepancies. Conclusions: The differences found between overall

  5. Discovery of multiple, ionization-created CS{sub 2} anions and a new mode of operation for drift chambers

    SciTech Connect

    Snowden-Ifft, Daniel P.

    2014-01-15

    This paper focuses on the surprising discovery of multiple species of ionization-created CS{sub 2} anions in gas mixtures containing electronegative CS{sub 2} and O{sub 2}, identified by their slightly different drift velocities. Data are presented to understand the formation mechanism and identity of these new anions. Regardless of the micro-physics, however, this discovery offers a new, trigger-less mode of operation for the drift chambers. A demonstration of trigger-less operation is presented.

  6. Lunar source of /sup 3/He for commercial fusion power

    SciTech Connect

    Wittenberg, L.J.; Santarius, J.F.; Kulcinski, G.L.

    1986-09-01

    An analysis of astrophysical information indicates that the solar wind has deposited an abundant, easily extractable source of /sup 3/He onto the surface of the moon. Apollo lunar samples indicate that the moon's surface soil contains approx. =10/sup 9/kg of /sup 3/He. If this amount of /sup 3/He were to be used in a 50% efficient D-/sup 3/He fusion reactor, it would provide 10/sup 7/GW(electric) . yr of electrical power. The energy required to extract /sup 3/He from the lunar regolith and transport it to earth is calculated to be approx. =2400 GJ/kg. Since the D-/sup 3/He reaction produces 6 X 10/sup 5/ GJ of energy per kilogram of /sup 3/He, the energy payback ratio is approx. =250. Implications for the commercialization of D-/sup 3/He fusion reactors and for the development of fusion power are discussed.

  7. 3He gas gap heat switch

    NASA Astrophysics Data System (ADS)

    Catarino, I.; Paine, C.

    2011-01-01

    Thermal control at 1 K is still demanding for heat switches development. A gas gap heat switch using 3He gas as the heat-transfer fluid was tested and characterized. The switch is actuated by a sorption pump, whose triggering temperatures were also characterized. Switching times were recorded for different thermalizations of the sorption pump. This paper presents the conductance results of such switch. The temperature scanning of the actuator is also presented. The effect of filling pressure is discussed as well as the thermalization of the sorption pump. About 60 μW/K OFF-state conductance and 100 mW/K ON-state conductance were obtained at 1.7 K. The actuation temperature is slightly adjustable upon the charging pressure of the working gas. Thermalization of the sorption pump at about 8-10 K is enough for producing an OFF state - it can be comfortably linked to a 4 K stage. Temperatures of 15-20 K at the sorption pump are required for reaching the viscous range for maximum ON conduction. Switching time dependence on the thermalization of the sorption pump is discarded.

  8. Effect of recombination in a high quantum efficiency prototype ionization-chamber-based electronic portal imaging device

    SciTech Connect

    Gopal, A.; Samant, S. S.

    2007-08-15

    The quantum efficiency (QE) of an imaging detector can be increased by utilizing a thick, high-density detection medium to increase the number of quantum interactions. However, image quality is more accurately described by the detection quantum efficiency (DQE). If a significant fraction of the increase in the number of detected quanta from a thick, dense detector were to result in useful imaging signal, this represents a favorable case where enhanced QE leads to increased DQE. However, for ionization-type detectors, one factor that limits DQE is the recombination between ion pairs that acts as a secondary quantum sink due to which enhancement in QE may not result in higher DQE depending on the extent of the signal loss from recombination. Therefore, an analysis of signal loss mechanisms or quantum sinks in an imaging system is essential for validating the overall benefit of high QE detectors. In this paper, a study of ion recombination as a secondary quantum sink is presented for a high QE prototype ion-chamber-based electronic portal imaging device (EPID): the kinestatic charge detector (KCD). The KCD utilizes a high pressure noble gas (krypton or xenon at 100 atm) and an arbitrarily large detector thickness (of the order of centimeters), resulting in a high QE imager. Compared with commercial amorphous silicon flat panel imagers that provide DQE(0){approx_equal}0.01, the KCD has much higher DQE. Studies indicated that DQE(0)=0.20 for 6.1 cm thick, 100 atm ({rho}=3.4 g/cm{sup 3}) xenon chamber, and DQE(0)=0.34 for a 9.1 cm thick chamber. A series of experiments was devised and conducted to determine the signal loss due to recombination for a KCD chamber. The measurements indicated a fractional recombination loss of about 14% for a krypton chamber and about 18% for a xenon chamber under standard operating conditions (100 atm chamber pressure and 1275 V/cm electric field intensity). A theoretical treatment of the effect of recombination on imaging signal

  9. Investigation and performance tests of a new parallel plate ionization chamber with double sensitive volume for measuring diagnostic X-rays

    NASA Astrophysics Data System (ADS)

    Sharifi, B.; Zamani Zeinali, H.; Soltani, J.; Negarestani, A.; Shahvar, A.

    2015-01-01

    Medical diagnostic equipment, like diagnostic radiology and mammography require a dosimeter with high accuracy for dosimetry of the diagnostic X-ray beam. Ionization chambers are suitable instruments for dosimetry of diagnostic-range X-ray beams because of their appropriate response and high reliability. This work introduces the design and fabrication of a new parallel plate ionization chamber with a PMMA body, graphite-coated PMMA windows (0.5 mm thick) and a graphite-foil central electrode (0.1 mm thick, 0.7 g/cm3 dense). This design improves upon the response characteristics of existing designs through the specific choice of materials as well as the appropriate size and arrangement of the ionization chamber components. The results of performance tests conducted at the Secondary Standard Dosimetry laboratory in Karaj-Iran demonstrated the short and long-term stability, the low leakage current, the low directional dependence, and the high ion collection efficiency of the design. Furthermore, the FLUKA Monte Carlo simulations confirmed the low effect of central electrode on this new ionization chamber response. The response characteristics of the parallel plate ionization chamber presented in this work makes the instrument suitable for use as a standard dosimeter in laboratories.

  10. DAVID—a translucent multi-wire transmission ionization chamber for in vivo verification of IMRT and conformal irradiation techniques

    NASA Astrophysics Data System (ADS)

    Poppe, B.; Thieke, C.; Beyer, D.; Kollhoff, R.; Djouguela, A.; Rühmann, A.; Willborn, K. C.; Harder, D.

    2006-03-01

    Permanent in vivo verification of IMRT photon beam profiles by a radiation detector with spatial resolution, positioned on the radiation entrance side of the patient, has not been clinically available so far. In this work we present the DAVID system, which is able to perform this quality assurance measurement while the patient is treated. The DAVID system is a flat, multi-wire transmission-type ionization chamber, placed in the accessory holder of the linear accelerator and constructed from translucent materials in order not to interfere with the light field. Each detection wire of the chamber is positioned exactly in the projection line of a MLC leaf pair, and the signal of each wire is proportional to the line integral of the ionization density along this wire. Thereby, each measurement channel essentially presents the line integral of the ionization density over the opening width of the associated leaf pair. The sum of all wire signals is a measure of the dose-area product of the transmitted photon beam and of the total radiant energy administered to the patient. After the dosimetric verification of an IMRT plan, the values measured by the DAVID system are stored as reference values. During daily treatment the signals are re-measured and compared to the reference values. A warning is output if there is a deviation beyond a threshold. The error detection capability is a leaf position error of less than 1 mm for an isocentric 1 cm × 1 cm field, and of 1 mm for an isocentric 20 cm × 20 cm field.

  11. DAVID--a translucent multi-wire transmission ionization chamber for in vivo verification of IMRT and conformal irradiation techniques.

    PubMed

    Poppe, B; Thieke, C; Beyer, D; Kollhoff, R; Djouguela, A; Rühmann, A; Willborn, K C; Harder, D

    2006-03-01

    Permanent in vivo verification of IMRT photon beam profiles by a radiation detector with spatial resolution, positioned on the radiation entrance side of the patient, has not been clinically available so far. In this work we present the DAVID system, which is able to perform this quality assurance measurement while the patient is treated. The DAVID system is a flat, multi-wire transmission-type ionization chamber, placed in the accessory holder of the linear accelerator and constructed from translucent materials in order not to interfere with the light field. Each detection wire of the chamber is positioned exactly in the projection line of a MLC leaf pair, and the signal of each wire is proportional to the line integral of the ionization density along this wire. Thereby, each measurement channel essentially presents the line integral of the ionization density over the opening width of the associated leaf pair. The sum of all wire signals is a measure of the dose-area product of the transmitted photon beam and of the total radiant energy administered to the patient. After the dosimetric verification of an IMRT plan, the values measured by the DAVID system are stored as reference values. During daily treatment the signals are re-measured and compared to the reference values. A warning is output if there is a deviation beyond a threshold. The error detection capability is a leaf position error of less than 1 mm for an isocentric 1 cm x 1 cm field, and of 1 mm for an isocentric 20 cm x 20 cm field. PMID:16481690

  12. SU-D-19A-01: Can Farmer-Type Ionization Chambers Be Used to Improve the Accuracy of Low-Energy Electron Beam Reference Dosimetry?

    SciTech Connect

    Muir, B R; McEwen, M R

    2014-06-01

    Purpose: To investigate the use of cylindrical Farmer-type ionization chambers to improve the accuracy of low-energy electron beam calibration. Historically, these chamber types have not been used in beams with incident energies less than 10 MeV (R{sub 5} {sub 0} < 4.3 cm) because early investigations suggested large (up to 5 %) fluence perturbation factors in these beams, implying that a significant component of uncertainty would be introduced if used for calibration. More recently, the assumptions used to determine perturbation corrections for cylindrical chambers have been questioned. Methods: Measurements are made with cylindrical chambers in Elekta Precise 4, 8 and 18 MeV electron beams. Several chamber types are investigated that employ graphite walls and aluminum electrodes with very similar specifications (NE2571, NE2505/3, FC65-G). Depth-ionization scans are measured in water in the 8 and 18 MeV beams. To reduce uncertainty from chamber positioning, measurements in the 4 MeV beam are made at the reference depth in Virtual Water™. The variability of perturbation factors is quantified by comparing normalized response of various chambers. Results: Normalized ion chamber response varies by less than 0.7 % for similar chambers at average electron energies corresponding to that at the reference depth from 4 or 6 MeV beams. Similarly, normalized measurements made with similar chambers at the reference depth in the 4 MeV beam vary by less than 0.4 %. Absorbed dose calibration coefficients derived from these results are stable within 0.1 % on average over a period of 6 years. Conclusion: These results indicate that the uncertainty associated with differences in fluence perturbations for cylindrical chambers with similar specifications is only 0.2 %. The excellent long-term stability of these chambers in both photon and electron beams suggests that these chambers might offer the best performance for all reference dosimetry applications.

  13. JPL research to develop a He-3/He-4 dilution refrigerator for space applications

    NASA Technical Reports Server (NTRS)

    Petrac, D.; Israelsson, U. E.; Jackson, H. W.; Strayer, D. M.

    1990-01-01

    A research program to develop a He-3/He-4 solution refrigerator for space applications is underway. The results of the effort to use an electric field as a substitute for gravity to control the He-3/He-4 mixture interface that separates phases in terrestrial units are described. Further, experimental results obtained from an engineering model of a single-cycle dilution refrigerator with a mixing chamber capable of operating in a zero-gravity environment are described. Future research and development plans are outlined, in particular the need to test the operation of a single-cycle as well as a continuously operating dilution refrigerator in space.

  14. A novel convolution-based approach to address ionization chamber volume averaging effect in model-based treatment planning systems

    NASA Astrophysics Data System (ADS)

    Barraclough, Brendan; Li, Jonathan G.; Lebron, Sharon; Fan, Qiyong; Liu, Chihray; Yan, Guanghua

    2015-08-01

    The ionization chamber volume averaging effect is a well-known issue without an elegant solution. The purpose of this study is to propose a novel convolution-based approach to address the volume averaging effect in model-based treatment planning systems (TPSs). Ionization chamber-measured beam profiles can be regarded as the convolution between the detector response function and the implicit real profiles. Existing approaches address the issue by trying to remove the volume averaging effect from the measurement. In contrast, our proposed method imports the measured profiles directly into the TPS and addresses the problem by reoptimizing pertinent parameters of the TPS beam model. In the iterative beam modeling process, the TPS-calculated beam profiles are convolved with the same detector response function. Beam model parameters responsible for the penumbra are optimized to drive the convolved profiles to match the measured profiles. Since the convolved and the measured profiles are subject to identical volume averaging effect, the calculated profiles match the real profiles when the optimization converges. The method was applied to reoptimize a CC13 beam model commissioned with profiles measured with a standard ionization chamber (Scanditronix Wellhofer, Bartlett, TN). The reoptimized beam model was validated by comparing the TPS-calculated profiles with diode-measured profiles. Its performance in intensity-modulated radiation therapy (IMRT) quality assurance (QA) for ten head-and-neck patients was compared with the CC13 beam model and a clinical beam model (manually optimized, clinically proven) using standard Gamma comparisons. The beam profiles calculated with the reoptimized beam model showed excellent agreement with diode measurement at all measured geometries. Performance of the reoptimized beam model was comparable with that of the clinical beam model in IMRT QA. The average passing rates using the reoptimized beam model increased substantially from 92.1% to

  15. Intelligent monitor functional model with ionization chamber for mixed nuclear radiation field measurements

    SciTech Connect

    Valcov, N.; Purghel, L.; Celarel, A.

    1998-12-31

    By using the statistical discrimination technique, the components of an ionization current, due to a mixed radiation field, may be simultaneously measured. A functional model, including a series manufactured gamma-ray ratemeter was done, as an intermediate step in the design of specialized nuclear instrumentation, in order to check the concept of statistical discrimination method. The obtained results are in good agreement with the estimations of the statistical discrimination method.

  16. Two-dimensional and quasi-three-dimensional dosimetry of hadron and photon beams with the Magic Cube and the Pixel Ionization Chamber.

    PubMed

    Cirio, R; Garelli, E; Schulte, R; Amerio, S; Boriano, A; Bourhaleb, F; Coutrakon, G; Donetti, M; Giordanengo, S; Koss, P; Madon, E; Marchetto, F; Nastasi, U; Peroni, C; Santuari, D; Sardo, A; Scielzo, G; Stasi, M; Trevisiol, E

    2004-08-21

    Two detectors for fast two-dimensional (2D) and quasi-three-dimensional (quasi-3D) verification of the dose delivered by radiotherapy beams have been developed at University and Istituto Nazionale di Fisica Nucleare (INFN) of Torino. The Magic Cube is a stack of strip-segmented ionization chambers interleaved with water-equivalent slabs. The parallel plate ionization chambers have a sensitive area of 24 x 24 cm2, and consist of 0.375 cm wide and 24 cm long strips. There are a total of 64 strips per chamber. The Magic Cube has been tested with the clinical proton beam at Loma Linda University Medical Centre (LLUMC), and was shown to be capable of fast and precise quasi-3D dose verification. The Pixel Ionization Chamber (PXC) is a detector with pixel anode segmentation. It is a 32 x 32 matrix of 1024 cylindrical ionization cells arranged in a square 24 x 24 cm2 area. Each cell has 0.4 cm diameter and 0.55 cm height, at a pitch of 0.75 cm separates the centre of adjacent cells. The sensitive volume of each single ionization cell is 0.07 cm3. The detectors are read out using custom designed front-end microelectronics and a personal computer-based data acquisition system. The PXC has been used to verify dynamic intensity-modulated radiotherapy for head-and-neck and breast cancers. PMID:15446800

  17. Two-dimensional and quasi-three-dimensional dosimetry of hadron and photon beams with the Magic Cube and the Pixel Ionization Chamber

    NASA Astrophysics Data System (ADS)

    Cirio, R.; Garelli, E.; Schulte, R.; Amerio, S.; Boriano, A.; Bourhaleb, F.; Coutrakon, G.; Donetti, M.; Giordanengo, S.; Koss, P.; Madon, E.; Marchetto, F.; Nastasi, U.; Peroni, C.; Santuari, D.; Sardo, A.; Scielzo, G.; Stasi, M.; Trevisiol, E.

    2004-08-01

    Two detectors for fast two-dimensional (2D) and quasi-three-dimensional (quasi-3D) verification of the dose delivered by radiotherapy beams have been developed at University and Istituto Nazionale di Fisica Nucleare (INFN) of Torino. The Magic Cube is a stack of strip-segmented ionization chambers interleaved with water-equivalent slabs. The parallel plate ionization chambers have a sensitive area of 24 × 24 cm2, and consist of 0.375 cm wide and 24 cm long strips. There are a total of 64 strips per chamber. The Magic Cube has been tested with the clinical proton beam at Loma Linda University Medical Centre (LLUMC), and was shown to be capable of fast and precise quasi-3D dose verification. The Pixel Ionization Chamber (PXC) is a detector with pixel anode segmentation. It is a 32 × 32 matrix of 1024 cylindrical ionization cells arranged in a square 24 × 24 cm2 area. Each cell has 0.4 cm diameter and 0.55 cm height, at a pitch of 0.75 cm separates the centre of adjacent cells. The sensitive volume of each single ionization cell is 0.07 cm3. The detectors are read out using custom designed front-end microelectronics and a personal computer-based data acquisition system. The PXC has been used to verify dynamic intensity-modulated radiotherapy for head-and-neck and breast cancers.

  18. Simulation of the Mg(Ar) ionization chamber currents by different Monte Carlo codes in benchmark gamma fields

    NASA Astrophysics Data System (ADS)

    Lin, Yi-Chun; Liu, Yuan-Hao; Nievaart, Sander; Chen, Yen-Fu; Wu, Shu-Wei; Chou, Wen-Tsae; Jiang, Shiang-Huei

    2011-10-01

    High energy photon (over 10 MeV) and neutron beams adopted in radiobiology and radiotherapy always produce mixed neutron/gamma-ray fields. The Mg(Ar) ionization chambers are commonly applied to determine the gamma-ray dose because of its neutron insensitive characteristic. Nowadays, many perturbation corrections for accurate dose estimation and lots of treatment planning systems are based on Monte Carlo technique. The Monte Carlo codes EGSnrc, FLUKA, GEANT4, MCNP5, and MCNPX were used to evaluate energy dependent response functions of the Exradin M2 Mg(Ar) ionization chamber to a parallel photon beam with mono-energies from 20 keV to 20 MeV. For the sake of validation, measurements were carefully performed in well-defined (a) primary M-100 X-ray calibration field, (b) primary 60Co calibration beam, (c) 6-MV, and (d) 10-MV therapeutic beams in hospital. At energy region below 100 keV, MCNP5 and MCNPX both had lower responses than other codes. For energies above 1 MeV, the MCNP ITS-mode greatly resembled other three codes and the differences were within 5%. Comparing to the measured currents, MCNP5 and MCNPX using ITS-mode had perfect agreement with the 60Co, and 10-MV beams. But at X-ray energy region, the derivations reached 17%. This work shows us a better insight into the performance of different Monte Carlo codes in photon-electron transport calculation. Regarding the application of the mixed field dosimetry like BNCT, MCNP with ITS-mode is recognized as the most suitable tool by this work.

  19. Studies of 3He+3He, T+3He, and p +D nuclear reactions relevant to stellar or Big-Bang Nucleosynthesis using ICF plasmas at OMEGA

    NASA Astrophysics Data System (ADS)

    Zylstra, Alex; Gatu Johnson, Maria; Frenje, Johan; Li, Chikang; Seguin, Fredrick; Sio, Hong; Rosenberg, Michael; Rinderknecht, Hans; Petrasso, Richard; Herrmann, Hans; Kim, Yong Ho; Hale, Gerry; McNabb, Dennis; Sayre, Dan; Pino, Jesse; Brune, Carl; Bacher, Andy; Forrest, Chad; Glebov, Vladimir; Stoeckl, Christian; Janezic, Roger; Sangster, Craig

    2014-10-01

    The 3He+3He, T+3He, and p +D reactions directly relevant to Stellar or Big-Bang Nucleosynthesis (BBN) have been studied at the OMEGA laser facility using high-temperature low-density `exploding pusher' implosions. The advantage of using these plasmas is that they better mimic astrophysical systems than cold-target accelerator experiments. Measured proton spectra from the 3He3He reaction are used to constrain nuclear R-matrix modeling. The resulting T+3He γ-ray data rule out an anomalously-high 6Li production during BBN as an explanation to the high observed values in primordial material. The proton spectrum from the T+3He reaction is also being used to constrain the R-matrix model. Recent experiments have probed the p +D reaction for the first time in a plasma; this reaction is relevant to energy production in protostars, brown dwarfs and at higher CM energies to BBN. This work was partially supported by the US DOE, NLUF, LLE, and GA.

  20. Measurement of the Coherent Neutron Scattering Length of 3He

    PubMed Central

    Ketter, W.; Heil, W.; Badurek, G.; Baron, M.; Loidl, R.; Rauch, H.

    2005-01-01

    By means of neutron interferometry the s-wave neutron scattering length of the 3He nucleus was re-measured at the Institut Laue-Langevin (ILL). Using a skew symmetrical perfect crystal Si-interferometer and a linear twin chamber cell, false phase shifts due to sample misalignment were reduced to a negligible level. Simulation calculations suggest an asymmetrically alternating measuring sequence in order to compensate for systematic errors caused by thermal phase drifts. There is evidence in the experiment’s data that this procedure is indeed effective. The neutron refractive index in terms of Sears’ exact expression for the scattering amplitude has been analyzed in order to evaluate the measured phase shifts. The result of our measurement, b′c = (6.000 ± 0.009) fm, shows a deviation towards a greater value compared to the presently accepted value of b′c = (5.74 ± 0.07) fm, confirming the observation of the partner experiment at NIST. On the other hand, the results of both precision measurements at NIST and ILL exhibit a serious 12σ (12 standard uncertainties) deviation, the reason for which is not clear yet.

  1. Characterization and performances of a monitoring ionization chamber dedicated to IBA-universal irradiation head for Pencil Beam Scanning

    NASA Astrophysics Data System (ADS)

    Courtois, C.; Boissonnat, G.; Brusasco, C.; Colin, J.; Cussol, D.; Fontbonne, J. M.; Marchand, B.; Mertens, T.; de Neuter, S.; Peronnel, J.

    2014-02-01

    Every radiotherapy center has to be equipped with real-time beam monitoring devices. In 2008, we developed an ionization chamber in collaboration with the IBA (Ion Beam Applications) company. This monitoring device called IC2/3 was developed to be used in IBA universal irradiation head for Pencil Beam Scanning (PBS). Here we present the characterization of the IC2/3 monitor in the energy and flux ranges used in protontherapy. The equipment has been tested with an IBA cyclotron able to deliver proton beams from 70 to 230 MeV. This beam monitoring device has been validated and is now installed at the Westdeutsches Protonentherapiezentrum Essen protontherapy center (WPE, Germany). The results obtained in both terms of spatial resolution and dose measurements are at least equal to the initial specifications needed for PBS purposes. The detector measures the dose with a relative uncertainty lower than 1% in the range from 0.5 Gy/min to 8 Gy/min while the spatial resolution is better than 250 μm. The technology has been patented and five IC2/3 chambers were delivered to IBA. Nowadays, IBA produces the IC2/3 beam monitoring device as a part of its Proteus 235 product.

  2. Recycling of 3He from lung magnetic resonance imaging.

    PubMed

    Salhi, Z; Grossmann, T; Gueldner, M; Heil, W; Karpuk, S; Otten, E W; Rudersdorf, D; Surkau, R; Wolf, U

    2012-06-01

    We have developed the means to recycle (3) He exhaled by patients after imaging the lungs using magnetic resonance of hyperpolarized (3) He. The exhaled gas is collected in a helium leak proof bag and further compressed into a steel bottle. The collected gas contains about 1-2% of (3) He, depending on the amount administered and the number of breaths collected to wash out the (3) He gas from the lungs. (3) He is separated from the exhaled air using zeolite molecular sieve adsorbent at 77 K followed by a cold head at 8 K. Residual gaseous impurities are finally absorbed by a commercial nonevaporative getter. The recycled (3) He gas features high purity, which is required for repolarization by metastability exchange optical pumping. At present, we achieve a collection efficiency of 80-84% for exhaled gas from healthy volunteers and cryogenic separation efficiency of 95%. PMID:22135249

  3. Electron beam quality k(Q,Q0) factors for various ionization chambers: a Monte Carlo investigation with PENELOPE.

    PubMed

    Erazo, F; Brualla, L; Lallena, A M

    2014-11-01

    In this work we calculate the beam quality correction factor k(Q,Q0) for various plane-parallel ionization chambers. A set of Monte Carlo calculations using the code PENELOPE/PENEASY have been carried out to calculate the overall correction factor f(c,Q) for eight electron beams corresponding to a Varian Clinac 2100 C/D, with nominal energies ranging between 6 MeV and 22 MeV, for a (60)Co beam, that has been used as the reference quality Q0 and also for eight monoenergetic electron beams reproducing the quality index R50 of the Clinac beams. Two field sizes, 10 × 10 cm(2) and 20 × 20 cm(2) have been considered. The k(Q,Q0) factors have been calculated as the ratio between f(c,Q) and f(c,Q0). Values for the Exradin A10, A11, A11TW, P11, P11TW, T11 and T11TW ionization chambers, manufactured by Standard Imaging, as well as for the NACP-02 have been obtained. The results found with the Clinac beams for the two field sizes analyzed show differences below 0.6%, even in the case of the higher energy electron beams. The k(Q,Q0) values obtained with the Clinac beams are 1% larger than those found with the monoenergetic beams for the higher energies, above 12 MeV. This difference can be ascribed to secondary photons produced in the linac head and the air path towards the phantom. Contrary to what was quoted in a previous work (Sempau et al 2004 Phys. Med. Biol. 49 4427-44), the beam quality correction factors obtained with the complete Clinac geometries and with the monoenergetic beams differ significantly for energies above 12 MeV. Material differences existing between chambers that have the same geometry produce non-negligible modifications in the value of these correction factors. PMID:25325343

  4. Electron beam quality kQ,Q0 factors for various ionization chambers: a Monte Carlo investigation with penelope

    NASA Astrophysics Data System (ADS)

    Erazo, F.; Brualla, L.; Lallena, A. M.

    2014-11-01

    In this work we calculate the beam quality correction factor {{k}\\text{Q,{{\\text{Q}}0}}} for various plane-parallel ionization chambers. A set of Monte Carlo calculations using the code penelope/penEasy have been carried out to calculate the overall correction factor fc,Q for eight electron beams corresponding to a Varian Clinac 2100 C/D, with nominal energies ranging between 6 MeV and 22 MeV, for a 60Co beam, that has been used as the reference quality Q0 and also for eight monoenergetic electron beams reproducing the quality index R50 of the Clinac beams. Two field sizes, 10 × 10 cm2 and 20 × 20 cm2 have been considered. The {{k}\\text{Q,{{\\text{Q}}0}}} factors have been calculated as the ratio between fc,Q and {{f}\\text{c,{{\\text{Q}}0}}} . Values for the Exradin A10, A11, A11TW, P11, P11TW, T11 and T11TW ionization chambers, manufactured by Standard Imaging, as well as for the NACP-02 have been obtained. The results found with the Clinac beams for the two field sizes analyzed show differences below 0.6%, even in the case of the higher energy electron beams. The {{k}\\text{Q,{{\\text{Q}}0}}} values obtained with the Clinac beams are 1% larger than those found with the monoenergetic beams for the higher energies, above 12 MeV. This difference can be ascribed to secondary photons produced in the linac head and the air path towards the phantom. Contrary to what was quoted in a previous work (Sempau et al 2004 Phys. Med. Biol. 49 4427-44), the beam quality correction factors obtained with the complete Clinac geometries and with the monoenergetic beams differ significantly for energies above 12 MeV. Material differences existing between chambers that have the same geometry produce non-negligible modifications in the value of these correction factors.

  5. /sup 3/He functions in tokamak-pumped laser systems

    SciTech Connect

    Jassby, D.L.

    1986-10-01

    /sup 3/He placed in an annular cell around a tokamak fusion generator can convert moderated fusion neutrons to energetic ions by the /sup 3/He(n,p)T reaction, and thereby excite gaseous lasants mixed with the /sup 3/He while simultaneously breeding tritium. The total /sup 3/He inventory is about 4 kg for large tokamak devices. Special configurations of toroidal-field magnets, neutron moderators and beryllium reflectors are required to permit nearly uniform neutron current into the laser cell with minimal attenuation. The annular laser radiation can be combined into a single output beam at the top of the tokamak.

  6. Dosimetry for the MRI accelerator: the impact of a magnetic field on the response of a Farmer NE2571 ionization chamber.

    PubMed

    Meijsing, I; Raaymakers, B W; Raaijmakers, A J E; Kok, J G M; Hogeweg, L; Liu, B; Lagendijk, J J W

    2009-05-21

    The UMC Utrecht is constructing a 1.5 T MRI scanner integrated with a linear accelerator (Lagendijk et al 2008 Radiother. Oncol. 86 25-9). The goal of this device is to facilitate soft-tissue contrast based image-guided radiotherapy, in order to escalate the dose to the tumour while sparing surrounding normal tissues. Dosimetry for the MRI accelerator has to be performed in the presence of a magnetic field. This paper investigates the feasibility of using a Farmer NE2571 ionization chamber for absolute dosimetry. The impact of the mcagnetic field on the response of this ionization chamber has been measured and simulated using GEANT4 Monte Carlo simulations. Two orientations of the ionization chamber with respect to the incident beam and the magnetic field which are feasible in the MRI accelerator configuration are taken into account. Measurements are performed using a laboratory magnet ranging from 0 to 1.2 T. In the simulations a range from 0 to 2 T is used. For both orientations, the measurements and simulations agreed within the uncertainty of the measurements and simulations. In conclusion, the response of the ionization chamber as a function of the magnetic field is understood and can be simulated using GEANT4 Monte Carlo simulations. PMID:19387100

  7. Thimble ionization chambers in medium-energy x-ray beams and the role of constructive details of the central electrode: Monte Carlo simulations and measurements

    NASA Astrophysics Data System (ADS)

    Ubrich, F.; Wulff, J.; Kranzer, R.; Zink, K.

    2008-09-01

    This paper presents investigations of thimble ionization chamber response in medium-energy kilovoltage x-ray beams (70-280 kVp, 0.09-3.40 mm Cu HVL). Two thimble ionization chambers (PTW30015 and PTW30016) were investigated, regarding the influence of the central electrode dimensions made of aluminum. Measurements were carried out in photon fields of different beam quality. Corresponding Monte Carlo simulations employing the EGSnrc Monte Carlo code system were performed. The simulations included the modelling of the x-ray tube and measurement setup for generation of x-ray spectra. These spectra were subsequently used to calculate the absorbed energy in the air cavity of the two thimble ionization chamber models and the air kerma at the reference point of the chambers. Measurements and simulations revealed an optimal diameter of the central electrode, concerning an almost energy-independent response of the ionizaton chamber. The Monte Carlo simulations are in good agreement with the measured values, expressed in beam quality correction factors kQ. The agreement was generally within 0.6% but could only be achieved with an accurate model of the central electrode including its exact shape. Otherwise, deviations up to 8.5% resulted, decreasing with higher photon energies, which can be addressed to the high yield of the photoelectric effect in the electrode material aluminum at low photon energies.

  8. NOTE: Determination of the recombination correction factor kS for some specific plane-parallel and cylindrical ionization chambers in pulsed photon and electron beams

    NASA Astrophysics Data System (ADS)

    Bruggmoser, G.; Saum, R.; Schmachtenberg, A.; Schmid, F.; Schüle, E.

    2007-01-01

    It has been shown from an evaluation of the inverse reading of the dosemeter (1/M) against the inverse of the polarizing voltage (1/V), obtained with a number of commercially available ionization chambers, using dose per pulse values between 0.16 and 5 mGy, that a linear relationship between the recombination correction factor kS and dose per pulse (DPP) can be found. At dose per pulse values above 1 mGy the method of a general equation with coefficients dependent on the chamber type gives more accurate results than the Boag method. This method was already proposed by Burns and McEwen (1998, Phys. Med. Biol. 43 2033) and avoids comprehensive and time-consuming measurements of Jaffé plots which are a prerequisite for the application of the multi-voltage analysis (MVA) or the two-voltage analysis (TVA). We evaluated and verified the response of ionization chambers on the recombination effect in pulsed accelerator beams for both photons and electrons. Our main conclusions are: (1) The correction factor kS depends only on the DPP and the chamber type. There is no influence of radiation type and energy. (2) For all the chambers investigated there is a linear relationship between kS and DPP up to 5 mGy/pulse, and for two chambers we could show linearity up to 40 mGy/pulse. (3) A general formalism, such as that of Boag, characterizes chambers exclusively by the distance of the electrodes and gives a trend for the correction factor, and therefore (4) a general formalism has to reflect the influence of the chamber construction on the recombination by the introduction of chamber-type dependent coefficients.

  9. Early Days of Superfluid ^3He: An Experimenter's View

    NASA Astrophysics Data System (ADS)

    Lee, David

    2010-03-01

    The formulation of the BCS theory led theorists to investigate possible non-S-wave pairing in liquid ^3He. Unfortunately as time went on, estimates for the pairing temperature became unattainably low. Nevertheless, the push to lower temperatures by experimentalists continued and was facilitated by the invention of the dilution refrigerator. Nuclear adiabatic demagnetization could then be used to cool liquid ^3He to ˜1 mK as demonstrated by Goodkind. An alternate approach, suggested by Pomeranchuk, involved adiabatic compression of liquid ^3He into the solid phase. Efforts to develop this technique at the Kapitza Institute, La Jolla and Cornell achieved success in demonstrating cooling of mixtures of liquid and solid ^3He to ˜ 1 mK following dilution refrigerator pre-cooling. Although there was great pessimism regarding the possible observation of pairing in liquid ^3He, the unsettled problem of magnetic ordering in solid ^3He beckoned. Ultimately two phase transition along the melting curve were observed by Osheroff et al at Cornell. Although first associated with solid ^3He, extensive NMR studies showed them to be two new phases of liquid ^3He. A brief history of experiments at various laboratories following the discovery is given, along with early interpretations given by Anderson and Morel and Balian and Werthamer. The key role of Leggett's spin dynamics is also discussed.

  10. Comparison of two dose-area-product ionization chambers with different conductive surface coating for over-table and under-table tube configurations

    SciTech Connect

    Bednarek, D.R.; Rudin, S.

    2000-03-01

    A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual DAP in the under-table case. The intrinsic response of the graphite chamber is nearly independent of tube potential. Although the variation of response with tube potential of the graphite chamber is increased when it is used as an over-table and an under-table patient monitor, it shows less overall variation of response than the VacuDAP. The average deviation of each range of 40 to 140 kVp for both chambers.

  11. Experimental analysis of general ion recombination in a liquid-filled ionization chamber in high-energy photon beams

    SciTech Connect

    Chung, Eunah; Seuntjens, Jan; Davis, Stephen

    2013-06-15

    Purpose: To study experimentally the general ion recombination effect in a liquid-filled ionization chamber (LIC) in high-energy photon beams. Methods: The general ion recombination effect on the response of a micro liquid ion chamber (microLion) was investigated with a 6 MV photon beam in normal and SRS modes produced from a Varian{sup Registered-Sign} Novalis Tx{sup TM} linear accelerator. Dose rates of the linear accelerator were set to 100, 400, and 1000 MU/min, which correspond to pulse repetition frequencies of 60, 240, and 600 Hz, respectively. Polarization voltages applied to the microLion were +800 and +400 V. The relative collection efficiency of the microLion response as a function of dose per pulse was experimentally measured with changing polarization voltage and pulse repetition frequencies and was compared with the theoretically calculated value. Results: For the 60 Hz pulse repetition frequency, the experimental relative collection efficiency was not different from the theoretical one for a pulsed beam more than 0.3% for both polarization voltages. For a pulsed radiation beam with a higher pulse repetition frequency, the experimental relative collection efficiency converged to the theoretically calculated efficiency for continuous beams. This result indicates that the response of the microLion tends toward the response to a continuous beam with increasing pulse repetition frequency of a pulsed beam because of low ion mobility in the liquid. Conclusions: This work suggests an empirical method to correct for differences in general ion recombination of a LIC between different radiation fields. More work is needed to quantitatively explain the LIC general ion recombination behavior in pulsed beams generated from linear accelerators.

  12. Laser Induced Fluorescence Spectroscopy of Neutral and Ionized Polycyclic Aromatic Hydrocarbons in a Cosmic Simulation Chamber

    NASA Astrophysics Data System (ADS)

    Bejaoui, Salma; Salama, Farid

    2015-08-01

    Polycyclic aromatic hydrocarbon (PAH) molecules are considered the best carriers to account for the ubiquitous infrared emission bands. PAHs have also been proposed as candidates to explain the diffuse interstellar bands (DIBs), a series of absorption features seen on the interstellar extinction curve and are plausible carriers for the extended red emission (ERE), a photoluminescent process associated with a wide variety of interstellar environments. Extensive efforts have been devoted over the past two decades to characterize the physical and chemical properties of PAH molecules and ions in space. Absorption spectra of PAH molecules and ions trapped in solid matrices have been compared to the DIBs [1, 2]. Absorption spectra of several cold, isolated gas-phase PAHs have also been measured under experimental conditions that mimic the interstellar conditions [see 3 for a review]. The purpose of this study is to provide a new dimension to the existing spectroscopic database of neutral and single ionized PAHs that is largely based on absorption spectra by adding emission spectroscopy data. The measurements are based on the laser-induced fluorescence (LIF) technique [4] and are performed with the Pulsed Discharge Nozzle (PDN) of the COSmIC laboratory facility at NASA Ames laboratory. The PDN generates plasma in a free supersonic jet expansion to simulate the physical and the chemical conditions in interstellar environments. We focus, here, on the fluorescence spectra of large neutral PAHs and their cations where there is a lack of fluorescence spectroscopy data. The astronomical implications of the data (e.g., ERE) are examinedReferences[1] F. Salama, E. Bakes, L.J. Allamandola, A.G.G.M. Tielens, Astrophys. J., 458 (1996) p.621[2] F. Salama, The ISO Revolution, EDP Sciences, Les Ulis, France (1999) p.65[3] Salama F., In Organic Matter in Space, IAU Symposium 251, Kwok & Sandford Eds.Cambridge University Press,4, S251,(2008), p. 357 (2008) and references therein.[4

  13. Experimental determination of the absorbed dose to water in a scanned proton beam using a water calorimeter and an ionization chamber

    NASA Astrophysics Data System (ADS)

    Gagnebin, Solange; Twerenbold, Damian; Pedroni, Eros; Meer, David; Zenklusen, Silvan; Bula, Christian

    2010-03-01

    The absorbed dose to water is the reference physical quantity for the energy absorbed in tissue when exposed to beams of ionizing radiation in radiotherapy. The SI unit of absorbed dose to water is the gray (Gy = 1 J/kg). Ionization chambers are used as the dosimeters of choice in the clinical environment because they show a high reproducibility and are easy to use. However, ionization chambers have to be calibrated in order to convert the measured electrical charge into absorbed dose to water. In addition, protocols require these conversion factors to be SI traceable to a primary standard of absorbed dose to water. We present experimental results where the ionization chamber used for the dosimetry for the scanned proton beam facility at PSI is compared with the direct determination of absorbed dose to water from the METAS primary standard water calorimeter. The agreement of 3.2% of the dose values measured by the two techniques are within their respective statistical uncertainties.

  14. On the interpretation of current-voltage curves in ionization chambers using the exact solution of the Thomson problem

    NASA Astrophysics Data System (ADS)

    Ridenti, M. A.; Pascholati, P. R.; Gonçalves, J. A. C.; Bueno, C. C.

    2015-09-01

    The I - ΔV characteristic curve of a well type ionization chamber irradiated with 192Ir sources (0.75 Ci-120 Ci) was fitted using the exact solution of the Thomson problem. The recombination coefficient and saturation current were estimated using this new approach. The saturation current was compared with the results of the conventional method based on Boag-Wilson formula. It was verified that differences larger than 1% between both methods only occurred at activities higher than 55 Ci. We concluded that this new approach is recommended for a more accurate estimate of the saturation current when it is not possible to measure currents satisfying the condition I /Isat > 0.95. From the calibration curve the average value of pairs of carriers created per unit volume was estimated to be equal to η = 8.1 ×10-3cm-3s-1 Bq-1 and from that value it was estimated that ~ 17 pairs were created on average per second for each decay of the source.

  15. Development of a high-resolution room-temperature compressed-xenon cylindrical ionization-chamber gamma radiation detector

    NASA Astrophysics Data System (ADS)

    Tepper, Gary C.; Losee, Jon R.; Palmer, Robert L.

    1998-07-01

    Highly compressed and purified xenon is emerging as an important detection medium for high resolution, room temperature gamma radiation spectroscopy. Detectors based on compressed xenon offer a unique combination of thermal stability, high energy resolution and large volume. Furthermore, fluid based detectors are not susceptible to radiation damage, and can be constructed in a variety of geometries. However, some important factors have delayed the development of practical xenon detectors for widespread use. These factors include the relatively high operational pressures and voltages and the need to maintain extremely high xenon purity. We have recently developed a 0.7 liter gridded ionization chamber xenon gamma radiation detector in a cylindrical geometry. The detector operates at room temperature and provides an intrinsic energy resolution of 1.8% at 662 keV which is five times greater than scintillation based spectrometers. The detector design and performance variables are discussed in comparison to a previous detector constructed in a planar geometry. Our results indicate that practical xenon detectors can now be developed for a wide variety of applications.

  16. Time-of-flight ERD with a 200 mm2 Si3N4 window gas ionization chamber energy detector

    NASA Astrophysics Data System (ADS)

    Julin, Jaakko; Laitinen, Mikko; Sajavaara, Timo

    2014-08-01

    Low energy heavy ion elastic recoil detection work has been carried out in Jyväskylä since 2009 using home made timing detectors, a silicon energy detector and a timestamping data acquisition setup forming a time-of-flight-energy telescope. In order to improve the mass resolution of the setup a new energy detector was designed to replace the silicon solid state detector, which suffered from radiation damage and had poor resolution for heavy recoils. In this paper the construction and operation of an isobutane filled gas ionization chamber with a 14 × 14 mm2 100 nm thick silicon nitride window are described. In addition to greatly improved energy resolution for heavy ions, the detector is also able to detect hydrogen recoils simultaneously in the energy range of 100-1000 keV. Additionally the detector has position sensitivity by means of timing measurement, which can be performed without compromising the performance of the detector in any other way. The achieved position sensitivity improves the depth resolution near the surface.

  17. The Unusual Behavior of Solar Wind 3He++

    NASA Astrophysics Data System (ADS)

    Gloeckler, George; Fisk, L. A.; Geiss, J.

    2016-07-01

    The first measurements of the isotopic ratio of solar wind He by the Apollo SWC experiment revealed that 3He/4He is not constant, but varies from ˜~4•10-4 to ˜~5.5•10-4. Such variations are modest compared with the 3He/4He variations often seen in Helium-3 rich SEP events. Here we report and compare detailed measurements with ACE/SWICS of the densities, bulk speeds and thermal speeds of solar wind 1H+, 4He++ and 3He++ during one Carrington rotation (in January 2005). The most remarkable finding is the factor of ˜~100 variation in the solar wind 3He++/4He++ number density ratio from a low value of ˜~5•10-5 to a high value of ˜~6•10-3. The highest ratios occurred during four time intervals of one to two days each. Large ratios are observed during periods of low (< ˜~20 km/s) 3He++ thermal speeds and when the bulk speeds as well as the thermal speeds of 1H+, 4He++ and 3He++ are almost the same. Small ratios, on the other hand, were found when the spread between the thermal speeds as well as between the bulk speeds of 1H+, 4He++ and 3He++ was large. During times of small 3He++/4He++ ratios the thermal speed of 3He++ was above 20 km/s, and the proton and 4He++ thermal speeds exceeded ˜~50 km/s and ˜~35 km/s, respectively. We will examine additional time periods to determine whether the compositional variations of solar wind helium during this particular Carrington rotation are unusual or common, and will speculate on possible mechanisms that could produce the factor of 100 variations in the isotopic solar wind He ratio.

  18. A two-dimensional liquid-filled ionization chamber array prototype for small-field verification: characterization and first clinical tests.

    PubMed

    Brualla-González, Luis; Gómez, Faustino; Vicedo, Aurora; González-Castaño, Diego M; Gago-Arias, Araceli; Pazos, Antonio; Zapata, Martín; Roselló, Joan V; Pardo-Montero, Juan

    2012-08-21

    In this work we present the design, characterization and first clinical tests of an in-house developed two-dimensional liquid-filled ionization chamber prototype for the verification of small radiotherapy fields and treatments containing such small fields as in radiosurgery, which consists of 2 mm × 2 mm pixels arranged on a 16×8 rectangular grid. The ionization medium is isooctane. The characterization of the device included the study of depth, field-size and dose-rate dependences, which are sufficiently moderate for a good operation at therapy radiation levels. However, the detector presents an important anisotropic response, up to ≃ 12% for front versus near-lateral incidence, which can impact the verification of full treatments with different incidences. In such a case, an anisotropy correction factor can be applied. Output factors of small square fields measured with the device show a small systematic over-response, less than 1%, when compared to unshielded diode measurements. An IMRT radiosurgery treatment has been acquired with the liquid-filled ionization chamber device and compared with film dosimetry by using the gamma method, showing good agreement: over 99% passing rates for 1.2% and 1.2 mm for an incidence-per-incidence analysis; 100% passing rates for tolerances 1.8% and 1.8 mm when the whole treatment is analysed and the anisotropy correction factor is applied. The point dose verification for each incidence of the treatment performed with the liquid-filled ionization chamber agrees within 1% with a CC01 ionization chamber. This prototype has shown the utility of this kind of technology for the verification of small fields/treatments. Currently, a larger device covering a 5 cm × 5 cm area is under development. PMID:22850081

  19. Recent Spin Pump Experiments on Superfluid 3He-A1

    NASA Astrophysics Data System (ADS)

    Yamaguchi, A.; Kamada, N.; Motoyama, G.; Sumiyama, A.; Aoki, Y.; Okuda, Y.; Kubota, M.; Kojima, H.

    2013-05-01

    The superfluid 3He A1 phase, containing a spin-polarized condensate allows us to explore the dynamics of superfluid spin current. In the mechano-spin effect (MSE), a mechanically applied pressure gradient and a superleak-spin filter enable one to directly boost spin polarization of 3He in a small chamber. We are developing new apparatus for achieving greater enhancement of spin density. A development of a new-type 3He-hydraulic actuator has been already reported. We present here the construction of new-type of superleak-spin-filter made of packed powder aluminum oxide (referred as PAP-SL). The PAP-SL is popular in the study of superfluid 4He, but has not been established for that of the superfluid 3He. The attempt to construct the PAP-SL for the spin pump experiment was made by using aluminum oxide powder with nominal 1 μm powder diameter and with packing fraction of 40 %. Before executing the experiment, the nuclear demagnetization cryostat of ISSP, Univ. Tokyo which has been used for this experimental activity, was heavily damaged by the 2011 Great East Japan (Higashi Nihon) Earthquake. The repair work and earthquake damage protection strengthening has just been accomplished.

  20. Dressed spin of polarized {sup 3}He in a cell

    SciTech Connect

    Chu, P.-H.; Esler, A. M.; Peng, J. C.; Beck, D. H.; Chandler, D. E.; Clayton, S.; Williamson, S.; Yoder, J.; Hu, B.-Z.; Ngan, S. Y.; Sham, C. H.; So, L. H.

    2011-08-15

    We report a measurement of the modification of the effective precession frequency of polarized {sup 3}He atoms in response to a dressing field in a room-temperature cell. The {sup 3}He atoms were polarized using the metastability spin-exchange method. An oscillating dressing field was then applied perpendicular to the constant magnetic field. Modification of the {sup 3}He effective precession frequency was observed over a broad range of the amplitude and frequency of the dressing field. The observed effects are compared with calculations based on quantum optics formalism.

  1. Dressed spin of polarized 3He in a cell

    NASA Astrophysics Data System (ADS)

    Chu, P.-H.; Esler, A. M.; Peng, J. C.; Beck, D. H.; Chandler, D. E.; Clayton, S.; Hu, B.-Z.; Ngan, S. Y.; Sham, C. H.; So, L. H.; Williamson, S.; Yoder, J.

    2011-08-01

    We report a measurement of the modification of the effective precession frequency of polarized 3He atoms in response to a dressing field in a room-temperature cell. The 3He atoms were polarized using the metastability spin-exchange method. An oscillating dressing field was then applied perpendicular to the constant magnetic field. Modification of the 3He effective precession frequency was observed over a broad range of the amplitude and frequency of the dressing field. The observed effects are compared with calculations based on quantum optics formalism.

  2. Recent Advances of Polarized 3He Target at Jefferson Lab

    SciTech Connect

    Yi Qiang

    2011-10-01

    Polarized {sup 3}He target has been widely used in nuclear and particle experiments to study the neutron structure in the spin degree of freedom, as most of the {sup 3}He spin is carried by the unpaired neutron. Spin-Exchange Optical Pumping (SEOP) process is used in Jefferson Lab Hall A to polarize its {sup 3}He target. Through developments in recent years, both the performance and corresponding polarimetry of such a target were greatly improved. Several experiments recently carried out in Hall A benefited remarkably from this target for the record highest figure of merit.

  3. Neutron Detection Alternatives to 3He for National Security Applications

    SciTech Connect

    Kouzes, Richard T.; Ely, James H.; Erikson, Luke E.; Kernan, Warnick J.; Lintereur, Azaree T.; Siciliano, Edward R.; Stephens, Daniel L.; Stromswold, David C.; Van Ginhoven, Renee M.; Woodring, Mitchell L.

    2010-11-21

    One of the main uses for 3He is in gas proportional counters for neutron detection. Large radiation detection systems deployed for homeland security and proliferation detection applications use such systems. Due to the large increase in use of 3He for homeland security and basic research, the supply has dwindled, and can no longer meet the demand. This has led to the search for an alternative technology to replace the use of 3He-based neutron detectors. In this paper, we review the testing of currently commercially available alternative technologies for neutron detection in large systems used in various national security applications.

  4. Shear Modulus and Dislocations in bcc Solid ^3He

    NASA Astrophysics Data System (ADS)

    Cheng, Zhi Gang; Souris, Fabien; Beamish, John

    2016-05-01

    The shear modulus of hcp ^4He decreases significantly above ˜ 200 mK, as ^3He impurities unbind from dislocations, unpinning them, and softening the crystal. Here we report shear modulus measurements on a fermi quantum solid: bcc ^3He. In contrast to previous low-frequency measurements, which did not show dislocation softening in this system, we have observed a drop in shear modulus, accompanied by a dissipation peak, which we attribute to the unpinning of dislocations as ^4He impurities unbind. For large stresses, impurities cannot pin the dislocations and the low temperature stiffening is suppressed. At high frequencies, the modulus changes and dissipation peaks shift to higher temperature, indicating that the unbinding is thermally activated. For a 58 bar bcc ^3He crystal, we find an activation energy of 0.27 K, smaller than the 0.7 K binding energy for ^3He impurities in hcp ^4He.

  5. Polar Phase of Superfluid (3)He in Anisotropic Aerogel.

    PubMed

    Dmitriev, V V; Senin, A A; Soldatov, A A; Yudin, A N

    2015-10-16

    We report the first observation of the polar phase of superfluid (3)He. This phase appears in (3)He confined in a new type of aerogel with a nearly parallel arrangement of strands which play the role of ordered impurities. Our experiments qualitatively agree with theoretical predictions and suggest that in other systems with unconventional Cooper pairing (e.g., in unconventional superconductors) similar phenomena may be found in the presence of anisotropic impurities. PMID:26550884

  6. Development of a Polarized 3He Ion Source for RHIC

    SciTech Connect

    Milner, Richard G.

    2013-01-15

    The goal of the project was to design and construct a source of polarized 3He atoms for injection into EBIS. This is the initial step in producing polarized 3He beams in RHIC in collaboration with physicists from Columbia University and Brookhaven National Laboratory. These beams can be used to probe the spin structure of the neutron in the existing RHIC complex as well as to measure precisely the Bjorken Sum Rule at a future eRHIC electron-ion collider.

  7. sup 3 He and methane in the Gulf of Aden

    SciTech Connect

    Jean-Baptiste, P.; Alaux, G. ); Belviso, S.; Nguyen, B.C.; Mihalopoulos, N. )

    1990-01-01

    During the OCEAT cruise (July, 1987), the vertical and spatial distributions of {sup 3}He and methane were measured at six stations over the West Sheba Ridge (Gulf of Aden). The results show significant {delta}{sup 3}He anomalies (up to 49%). The authors conclude that the origin of this signal is independent from the well known Red Sea hydrothermal {sup 3}He (of the Red Sea Brines). Thus, active hydrothermalism occurs in this extensional basin associated with spreading along an incipient mid-ocean ridge. The {sup 3}He input from the Gulf of Aden accounts for the S-N positive gradient in {sup 3}He concentration observed in the western part of the Indian Ocean. Several methane anomalies are also present (up to 664 nl/l,i.e., 25 times the regional methane background), but the CH{sub 4} and {sup 3}He signals are not systematically correlated, suggesting complex production and consumption mechanisms of methane in these areas. The authors results confirm previous observations in the South West Pacific Ocean.

  8. Gas gain operations with single photon resolution using an integrating ionization chamber in small-angle X-ray scattering experiments

    NASA Astrophysics Data System (ADS)

    Menk, R. H.; Sarvestani, A.; Besch, H. J.; Walenta, A. H.; Amenitsch, H.; Bernstorff, S.

    2000-01-01

    In this work a combination of an ionization chamber with one-dimensional spatial resolution and a MicroCAT structure will be presented. Initially, MicroCAT was thought of as a shielding grid (Frisch-grid) but later was used as an active electron amplification device that enables single X-ray photon resolution measurements at low fluxes even with integrating readout electronics. Moreover, the adjustable gas gain that continuously covers the entire range from pure ionization chamber mode up to high gas gains (30 000 and more) provides stable operation yielding a huge dynamic range of about 10 8 and more. First measurements on biological samples using small angle X-ray scattering techniques with synchrotron radiation will be presented.

  9. Chemical ionization mass spectrometric measurements of SO2 emissions from jet engines in flight and test chamber operations

    NASA Astrophysics Data System (ADS)

    Hunton, D. E.; Ballenthin, J. O.; Borghetti, J. F.; Federico, G. S.; Miller, T. M.; Thorn, W. F.; Viggiano, A. A.; Anderson, B. E.; Cofer, W. R.; McDougal, D. S.; Wey, C. C.

    2000-11-01

    We report the results of two measurements of the concentrations and emission indices of gas-phase sulfur dioxide (EI(SO2)) in the exhaust of an F100-200E turbofan engine. The broad goals of both experiments were to obtain exhaust sulfur speciation and aerosol properties as a function of fuel sulfur content. In the first campaign, an instrumented NASA T-39 Sabreliner aircraft flew in close formation behind several F-16 fighter aircraft to obtain near-field plume composition and aerosol properties. In the second, an F-100 engine of the same type was installed in an altitude test chamber at NASA Glenn Research Center where gas composition and nonvolatile aerosol concentrations and size distributions were obtained at the exit plane of the engine. In both experiments, SO2 concentrations were measured with the Air Force Research Laboratory chemical ionization mass spectrometer as a function of altitude, engine power, and fuel sulfur content. A significant aspect of the program was the use of the same fuels, the same engine type, and many of the same diagnostics in both campaigns. Several different fuels were purchased specifically for these experiments, including high-sulfur Jet A (˜1150 ppmm S), low-sulfur Jet A (˜10 ppmm S), medium-sulfur mixtures of these two fuels, and military JP-8+100 (˜170 and ˜300 ppmm S). The agreement between the flight and test cell measurements of SO2 concentrations was excellent, showing an overall precision of better than ±10% and an estimated absolute accuracy of ±20%. The EI(SO2) varied from 2.49 g SO2/kg fuel for the high-sulfur fuel in the test chamber to less than 0.01 g/kg for the lowest-sulfur fuel. No dependence of emission index on engine power, altitude or simulated altitude, separation distance or plume age, or the presence of contrails was observed. In all experiments the measured EI(SO2) was consistent with essentially all of the fuel sulfur appearing as gas-phase SO2 in the exhaust. However, accurate determination of S

  10. Comparison of depth-dose distributions of proton therapeutic beams calculated by means of logical detectors and ionization chamber modeled in Monte Carlo codes

    NASA Astrophysics Data System (ADS)

    Pietrzak, Robert; Konefał, Adam; Sokół, Maria; Orlef, Andrzej

    2016-08-01

    The success of proton therapy depends strongly on the precision of treatment planning. Dose distribution in biological tissue may be obtained from Monte Carlo simulations using various scientific codes making it possible to perform very accurate calculations. However, there are many factors affecting the accuracy of modeling. One of them is a structure of objects called bins registering a dose. In this work the influence of bin structure on the dose distributions was examined. The MCNPX code calculations of Bragg curve for the 60 MeV proton beam were done in two ways: using simple logical detectors being the volumes determined in water, and using a precise model of ionization chamber used in clinical dosimetry. The results of the simulations were verified experimentally in the water phantom with Marcus ionization chamber. The average local dose difference between the measured relative doses in the water phantom and those calculated by means of the logical detectors was 1.4% at first 25 mm, whereas in the full depth range this difference was 1.6% for the maximum uncertainty in the calculations less than 2.4% and for the maximum measuring error of 1%. In case of the relative doses calculated with the use of the ionization chamber model this average difference was somewhat greater, being 2.3% at depths up to 25 mm and 2.4% in the full range of depths for the maximum uncertainty in the calculations of 3%. In the dose calculations the ionization chamber model does not offer any additional advantages over the logical detectors. The results provided by both models are similar and in good agreement with the measurements, however, the logical detector approach is a more time-effective method.

  11. Large area neutron detector based on Li6 ionization chamber with integrated body-moderator of high density polyethylene

    SciTech Connect

    Ianakiev, Kiril D.; Swinhoe, Martyn T.; Chung, Kiwhan; Makela, Mark F.

    2009-06-30

    A detector was developed and funded by DHS to be a lower cost alternative to 3He detectors. A 6Li foil-lined ionization chamber was prepared with fill gas at one atmosphere and pulse mode operation. The high-density polyethylene (HOPE) body serves also as a neutron moderator. All electrodes, including high voltage bias supply, are hermetically sealed within the plastic slabs.

  12. Measurement of absorbed dose-to-water for an HDR {sup 192}Ir source with ionization chambers in a sandwich setup

    SciTech Connect

    Araki, Fujio; Kouno, Tomohiro; Ohno, Takeshi; Kakei, Kiyotaka; Yoshiyama, Fumiaki; Kawamura, Shinji

    2013-09-15

    Purpose: In this study, a dedicated device for ion chamber measurements of absorbed dose-to-water for a Nucletron microSelectron-v2 HDR {sup 192}Ir brachytherapy source is presented. The device uses two ionization chambers in a so-called sandwich assembly. Using this setup and by taking the average reading of the two chambers, any dose error due to difficulties in absolute positioning (centering) of the source in between the chambers is cancelled to first order. The method's accuracy was examined by comparing measurements with absorbed dose-to-water determination based on the AAPM TG-43 protocol.Methods: The optimal source-to-chamber distance (SCD) for {sup 192}Ir dosimetry was determined from ion chamber measurements in a water phantom. The {sup 192}Ir source was sandwiched between two Exradin A1SL chambers (0.057 cm{sup 3}) at the optimal SCD separation. The measured ionization was converted to the absorbed dose-to-water using a {sup 60}Co calibration factor and a Monte Carlo-calculated beam quality conversion factor, k{sub Q}, for {sup 60}Co to {sup 192}Ir. An uncertainty estimate of the proposed method was determined based on reproducibility of measurements at different institutions for the same type of source.Results: The optimal distance for the A1SL chamber measurements was determined to be 5 cm from the {sup 192}Ir source center, considering the depth dependency of k{sub Q} for {sup 60}Co to {sup 192}Ir and the chamber positioning. The absorbed dose to water measured at (5 cm, 90°) on the transverse axis was 1.3% lower than TG-43 values and its reproducibility and overall uncertainty were 0.8% and 1.7%, respectively. The measurement doses at anisotropic points agreed within 1.5% with TG-43 values.Conclusions: The ion chamber measurement of absorbed dose-to-water with a sandwich method for the {sup 192}Ir source provides a more accurate, direct, and reference dose compared to the dose-to-water determination based on air-kerma strength in the TG-43 protocol

  13. SU-E-T-561: Development of Depth Dose Measurement Technique Using the Multilayer Ionization Chamber for Spot Scanning Method

    SciTech Connect

    Takayanagi, T; Fujitaka, S; Umezawa, M; Ito, Y; Nakashima, C; Matsuda, K

    2014-06-01

    Purpose: To develop a measurement technique which suppresses the difference between profiles obtained with a multilayer ionization chamber (MLIC) and with a water phantom. Methods: The developed technique multiplies the raw MLIC data by a correction factor that depends on the initial beam range and water equivalent depth. The correction factor is derived based on a Bragg curve calculation formula considering range straggling and fluence loss caused by nuclear reactions. Furthermore, the correction factor is adjusted based on several integrated depth doses measured with a water phantom and the MLIC. The measured depth dose profiles along the central axis of the proton field with a nominal field size of 10 by 10 cm were compared between the MLIC using the new technique and the water phantom. The spread out Bragg peak was 20 cm for fields with a range of 30.6 cm and 6.9 cm. Raw MLIC data were obtained with each energy layer, and integrated after multiplying by the correction factor. The measurements were performed by a spot scanning nozzle at Nagoya Proton Therapy Center, Japan. Results: The profile measured with the MLIC using the new technique is consistent with that of the water phantom. Moreover, 97% of the points passed the 1% dose /1mm distance agreement criterion of the gamma index. Conclusion: We have demonstrated that the new technique suppresses the difference between profiles obtained with the MLIC and with the water phantom. It was concluded that this technique is useful for depth dose measurement in proton spot scanning method.

  14. SU-D-213-04: Accounting for Volume Averaging and Material Composition Effects in An Ionization Chamber Array for Patient Specific QA

    SciTech Connect

    Fugal, M; McDonald, D; Jacqmin, D; Koch, N; Ellis, A; Peng, J; Ashenafi, M; Vanek, K

    2015-06-15

    Purpose: This study explores novel methods to address two significant challenges affecting measurement of patient-specific quality assurance (QA) with IBA’s Matrixx Evolution™ ionization chamber array. First, dose calculation algorithms often struggle to accurately determine dose to the chamber array due to CT artifact and algorithm limitations. Second, finite chamber size and volume averaging effects cause additional deviation from the calculated dose. Methods: QA measurements were taken with the Matrixx positioned on the treatment table in a solid-water Multi-Cube™ phantom. To reduce the effect of CT artifact, the Matrixx CT image set was masked with appropriate materials and densities. Individual ionization chambers were masked as air, while the high-z electronic backplane and remaining solid-water material were masked as aluminum and water, respectively. Dose calculation was done using Varian’s Acuros XB™ (V11) algorithm, which is capable of predicting dose more accurately in non-biologic materials due to its consideration of each material’s atomic properties. Finally, the exported TPS dose was processed using an in-house algorithm (MATLAB) to assign the volume averaged TPS dose to each element of a corresponding 2-D matrix. This matrix was used for comparison with the measured dose. Square fields at regularly-spaced gantry angles, as well as selected patient plans were analyzed. Results: Analyzed plans showed improved agreement, with the average gamma passing rate increasing from 94 to 98%. Correction factors necessary for chamber angular dependence were reduced by 67% compared to factors measured previously, indicating that previously measured factors corrected for dose calculation errors in addition to true chamber angular dependence. Conclusion: By comparing volume averaged dose, calculated with a capable dose engine, on a phantom masked with correct materials and densities, QA results obtained with the Matrixx Evolution™ can be significantly

  15. Final state interaction in (3He, 2He) reactions

    NASA Astrophysics Data System (ADS)

    Congedo, T. V.; Lee-Fan, I. S.; Cohen, B. L.

    1980-09-01

    The two protons from 2He breakup following (3He, 2He) reactions were detected in coincidence, and energy and angular correlations between them were studied and compared with predictions of the final state interaction theories of Watson and Migdal and Phillips, Griffy, and Biedenharn. The angular correlation between the breakup protons drops off much faster than predicted by these theories; a final state interaction empirically derived to fit the angular correlation is sharply peaked at a breakup energy ~ 0.6 MeV and is quite narrow. Energy distributions of the protons have a dip at the center for small correlation angles which disappears at larger angles. This is well predicted by all final state interaction theories but the slopes of these distributions are much better fit by the empirical final state interaction than by Watson and Migdal or by Phillips, Griffy, and Biedenharn. By maintaining a constant small correlation angle (proton detectors close together), 2He angular distributions were measured and found to be in good agreement with distorted-wave Born approximation predictions. NUCLEAR REACTIONS 64Ni(3He, 2p), E=13 MeV; measured σ(θ), pp correlation; deduced pp FSI; calculated 2He detection efficiency. 9Be(3He, 2p), E=13 MeV; measured σ(θ). 27Al, 90Zr(3He, 2p) measured pp correlation. 51V, 65Cu, 89Y(3He, 2p), E=13 MeV, 17 MeV, measured σ(θ), DWBA analysis.

  16. 3He Films as Model Strongly Correlated Fermion Systems

    SciTech Connect

    Neumann, Michael; Casey, Andrew; Nyeki, Jan; Cowan, Brian; Saunders, John

    2006-09-07

    Helium films on graphite are atomically layered. This allows a wide variety of studies of strong correlations in two dimensions with density as a continuously tunable parameter. Studies of a monolayer of 3He adsorbed on graphite plated by a bi-layer of HD find a divergence of effective mass with increasing density, corresponding to a Mott-Hubbard transition between a 2D Fermi liquid and a quantum spin liquid phase. While the Fermi liquid survives in 2D, non-Fermi liquid features remain at finite T, recent theories find that this correction arises from the spin component of the backscattering amplitude. In another experiment a 3He film is grown on graphite plated by a bi-layer of 3He. The first 3He layer only solidifies in the presence of an overlayer. However in the regime in which the system comprises a 3He fluid bilayer, we observe a striking maximum in the temperature dependence of both heat capacity and magnetization. This feature is driven towards T = 0 with increasing film coverage, suggestive of a quantum critical point. Well below the maximum a linear temperature dependence of the heat capacity is recovered; the coverage dependence of the effective mass identifies a (bandwidth driven) Mott-Hubbard transition at 9.8 nm-2.

  17. Polarized 3He Spin Filters for Slow Neutron Physics

    PubMed Central

    Gentile, T. R.; Chen, W. C.; Jones, G. L.; Babcock, E.; Walker, T. G.

    2005-01-01

    Polarized 3He spin filters are needed for a variety of experiments with slow neutrons. Their demonstrated utility for highly accurate determination of neutron polarization are critical to the next generation of betadecay correlation coefficient measurements. In addition, they are broadband devices that can polarize large area and high divergence neutron beams with little gamma-ray background, and allow for an additional spin-flip for systematic tests. These attributes are relevant to all neutron sources, but are particularly well-matched to time of flight analysis at spallation sources. There are several issues in the practical use of 3He spin filters for slow neutron physics. Besides the essential goal of maximizing the 3He polarization, we also seek to decrease the constraints on cell lifetimes and magnetic field homogeneity. In addition, cells with highly uniform gas thickness are required to produce the spatially uniform neutron polarization needed for beta-decay correlation coefficient experiments. We are currently employing spin-exchange (SE) and metastability-exchange (ME) optical pumping to polarize 3He, but will focus on SE. We will discuss the recent demonstration of 75 % 3He polarization, temperature-dependent relaxation mechanism of unknown origin, cell development, spectrally narrowed lasers, and hybrid spin-exchange optical pumping. PMID:27308140

  18. Dynamics of vortex nucleation in sup 3 He- A flow

    SciTech Connect

    Kopnin, N.B.; Soininen, P.I.; Salomaa, M.M. )

    1992-03-01

    Quantum phase slippage in superfluid {sup 3}He flow is simulated numerically in rectangular slab geometries. Assuming that the flow is confined to a channel having horizontal surfaces close to each other, the spatial problem reduces to the two transverse dimensions; we report time-dependent computer simulations of superfluid {sup 3}He flow in 2+1 dimensions using the time-dependent Ginzburg-Landau equations. The quantum-dynamic processes of phase slippage in {sup 3}He are demonstrated to be associated with superfluid vortex nucleation; we thus confirm Anderson's assumption for phase slippage through vortex motion in superfluids. We also find several other phase-slip scenarios involving vortices, phase-slip lines, and combinations thereof for the coupled multicomponent order-parameter amplitudes. We consider both diffuse and specular boundary conditions at the side walls and demonstrate that our results are essentially independent of the boundaries. We compute the critical current for vortex nucleation as a function of the channel width, and compare it with existing theories of vortex nucleation; we also discuss our calculations in connection with experiments on phase slippage in {sup 3}He flow. One of our most important results is that the superfluid order parameter for the vortices generated in the computer simulations does not vanish anywhere; i.e., the vortices possess superfluid core structures; hence the processes of phase slip for superfluid {sup 3}He are nonlocal in space-time.

  19. Solar source regions of 3HE-rich particle events

    NASA Technical Reports Server (NTRS)

    Reames, D. V.; Stone, R. G.; Kahler, S. W.; Lin, R. P.; Liggett, M.

    1985-01-01

    Hydrogen alpha X-ray, and metric and kilometric radio data to examine the solar sources of energetic 3He-rich particle events observed near earth in association with impulsive 2 to 100 keV electron events were applied. Each 3He/electron event is associated with a kilometric type 3 burst belonging to a family of such bursts characterized by similar interplanetary propagation paths from the same solar active region. The 3He/electron events correlate very well with the interplanetary low frequency radio brightnesses of these events, but progressively worse with signatures from regions closer to the Sun. When H alpha brightnings can be associated with 3He/electron events, they have onsets coinciding to within 1 min of that of the associated metric type 3 burst but are often too small to be reported. The data are consistent with the earlier idea that many type 3 bursts, the 3He/electron events, are due to particle acceleration in the corona, well above the associated H alpha and X-ray flares.

  20. Supersymmetric dark matter search via spin-dependent interaction with 3He

    NASA Astrophysics Data System (ADS)

    Moulin, E.; Mayet, F.; Santos, D.

    2005-05-01

    The potentialities of MIMAC-He3, a MIcro-tpc MAtrix of Chambers of Helium-3, for supersymmetric dark matter search are discussed within the framework of effective MSSM models without gaugino mass unification at the GUT scale. A phenomenological study has been done to investigate the sensitivity of the MIMAC-He3 detector to neutralinos (M≳6GeV/c) via spin-dependent interaction with 3He as well as its complementarity to direct and indirect detection experiments. Comparison with other direct dark matter searches will be presented in a WIMP model-independent framework.

  1. Quark-Hadron Duality in Neutron (3He) Spin Structure

    SciTech Connect

    Solvignon, Patricia; Liyanage, Nilanga; Chen, Jian-Ping; Choi, Seonho; Aniol, Konrad; Averett, Todd; Boeglin, Werner; Camsonne, Alexandre; Cates, Gordon; Chang, C.; Chang, C.C.; Chang, C.; Chang, C.C.; Chudakov, Eugene; Craver, Brandon; Cusanno, Francesco; Deur, Alexandre; Dutta, Dipangkar; Ent, Rolf; Feuerbach, Robert; Frullani, Salvatore; Gao, Haiyan; Garibaldi, Franco; Gilman, Ronald; Glashausser, Charles; Gorbenko, Viktor; Hansen, Jens-Ole; Higinbotham, Douglas; Ibrahim, Hassan; Jiang, Xiaodong; Jones, Mark; Kelleher, Aidan; Kelly, J.; Keppel, Cynthia; Kim, Wooyoung; Korsch, Wolfgang; Kramer, Kevin; Kumbartzki, Gerfried; LeRose, John; Lindgren, Richard; Ma, Bin; Margaziotis, Demetrius; Markowitz, Pete; McCormick, Kathy; Meziani, Zein-Eddine; Michaels, Robert; Moffit, Bryan; Monaghan, Peter; Munoz-Camacho, Carlos; Paschke, Kent; Reitz, Bodo; Saha, Arunava; Sheyor, Ran; Singh, Jaideep; Slifer, Karl; Sulkosky, Vince; Sulkosky, Vincent; Sulkosky, Vince; Sulkosky, Vincent; Tobias, William; Urciuoli, Guido; Wang, Kebin; Wijesooriya, Krishni; Wojtsekhowski, Bogdan; Woo, Seungtae; Yang, Jae-Choon; Zheng, Xiaochao; Zhu, Lingyan

    2008-10-01

    We present experimental results of the first high-precision test of quark-hadron duality in the spin-structure function g_1 of the neutron and $^3$He using a polarized 3He target in the four-momentum-transfer-squared range from 0.7 to 4.0 (GeV/c)^2. Global duality is observed for the spin-structure function g_1 down to at least Q^2 = 1.8 (GeV/c)^2 in both targets. We have also formed the photon-nucleon asymmetry A_1 in the resonance region for 3He and found no strong Q^2-dependence above 2.2 (GeV/c)^2.

  2. Light-Front Dynamics and the {{3He}} Spectral Function

    NASA Astrophysics Data System (ADS)

    Pace, Emanuele; Del Dotto, Alessio; Kaptari, Leonid; Rinaldi, Matteo; Salmé, Giovanni; Scopetta, Sergio

    2016-07-01

    Two topics are presented. The first one is a novel approach for a Poincaré covariant description of nuclear dynamics based on light-front Hamiltonian dynamics. The key quantity is the light-front spectral function, where both normalization and momentum sum rule can be satisfied at the same time. Preliminary results are discussed for an initial analysis of the role of relativity in the EMC effect in {{3He}}. A second issue, very challenging, is considered in a non-relativistic framework, namely a distorted spin-dependent spectral function for {{3He}} in order to take care of the final state interaction between the observed pion and the remnant in semi-inclusive deep inelastic electron scattering off polarized {{3He}}. The generalization of the analysis within the light-front dynamics is outlined.

  3. Ultrasensitive 3He magnetometer for measurements of high magnetic fields

    NASA Astrophysics Data System (ADS)

    Nikiel, Anna; Blümler, Peter; Heil, Werner; Hehn, Manfred; Karpuk, Sergej; Maul, Andreas; Otten, Ernst; Schreiber, Laura M.; Terekhov, Maxim

    2014-11-01

    We describe a 3He magnetometer capable to measure high magnetic fields ( B> 0.1 T) with a relative accuracy of better than 10-12. Our approach is based on the measurement of the free induction decay of gaseous, nuclear spin polarized 3He following a resonant radio frequency pulse excitation. The measurement sensitivity can be attributed to the long coherent spin precession time T2 ∗ being of order minutes which is achieved for spherical sample cells in the regime of "motional narrowing" where the disturbing influence of field inhomogeneities is strongly suppressed. The 3He gas is spin polarized in situ using a new, non-standard variant of the metastability exchange optical pumping. We show that miniaturization helps to increase T2 ∗ further and that the measurement sensitivity is not significantly affected by temporal field fluctuations of order 10-4.

  4. Strong-Coupling and the Stripe Phase of ^3He

    NASA Astrophysics Data System (ADS)

    Wiman, Joshua J.; Sauls, J. A.

    2016-09-01

    Thin films of superfluid 3He were predicted, based on weak-coupling BCS theory, to have a stable phase which spontaneously breaks translational symmetry in the plane of the film. This crystalline superfluid, or "stripe" phase, develops as a one-dimensional periodic array of domain walls separating degenerate B phase domains. We report calculations of the phases and phase diagram for superfluid 3He in thin films using a strong-coupling Ginzburg-Landau theory that accurately reproduces the bulk 3He superfluid phase diagram. We find that the stability of the Stripe phase is diminished relative to the A phase, but the Stripe phase is stable in a large range of temperatures, pressures, confinement, and surface conditions.

  5. Nuclear electric dipole moment of {sup 3}He

    SciTech Connect

    Stetcu, I.; Friar, J. L.; Hayes, A. C.; Liu, C.-P.; Navratil, P.

    2009-01-28

    In the no-core shell model (NCSM) framework, we calculate the {sup 3}He electric dipole moment (EDM) generated by parity- and time-reversal violation in the nucleon-nucleon interaction. While the results are somehow sensitive to the interaction model chosen for the strong two- and three-body interactions, we demonstrate the pion-exchange dominance to the EDM of {sup 3}He, if the coupling constants for {pi}, {rho} and {omega}-exchanges are of comparable magnitude, as expected. Finally, our results suggest that a measurement of {sup 3}He EDM would be complementary to the currently planned neutron and deuteron experiments, and would constitute a powerful constraint to the models of the pion P- and T-violating interactions.

  6. Surface Waves on the Superfluids ^3He and ^4He

    NASA Astrophysics Data System (ADS)

    Manninen, M. S.; Ranni, A.; Rysti, J.; Todoshchenko, I. A.; Tuoriniemi, J. T.

    2016-06-01

    Free surface waves were examined both in superfluids ^3He and ^4He with the premise that these inviscid media would represent ideal realizations for this fluid dynamics problem. The work in ^3He is one of the first of its kind, but in ^4He, it was possible to produce a much more complete set of data for meaningful comparison with theoretical models. Most measurements were performed at the zero temperature limit, meaning T< 100 mK for ^4He and T˜ 100 μ K for ^3He. Dozens of surface wave resonances, including up to 11 overtones, were observed and monitored as the liquid depth in the cell was varied. Despite of the wealth of data, perfect agreement with the constructed theoretical models could not be achieved.

  7. Surface Waves on the Superfluids ^3 He and ^4 He

    NASA Astrophysics Data System (ADS)

    Manninen, M. S.; Ranni, A.; Rysti, J.; Todoshchenko, I. A.; Tuoriniemi, J. T.

    2016-04-01

    Free surface waves were examined both in superfluids ^3 He and ^4 He with the premise that these inviscid media would represent ideal realizations for this fluid dynamics problem. The work in ^3 He is one of the first of its kind, but in ^4 He, it was possible to produce a much more complete set of data for meaningful comparison with theoretical models. Most measurements were performed at the zero temperature limit, meaning T< 100 mK for ^4 He and T˜ 100 μ K for ^3 He. Dozens of surface wave resonances, including up to 11 overtones, were observed and monitored as the liquid depth in the cell was varied. Despite of the wealth of data, perfect agreement with the constructed theoretical models could not be achieved.

  8. Coherent photoproduction of {pi}{sup +} from {sup 3}He

    SciTech Connect

    Nasseripour, R.; Berman, B.L.; Briscoe, W.J.; Micherdzinska, A.M.; Munevar, E.; Adhikari, K.P.; Adikaram, D.; Hyde, C.E.; Klein, A.; Kuhn, S.E.; Mayer, M.; Seraydaryan, H.; Weinstein, L.B.; Anghinolfi, M.; Battaglieri, M.; De Vita, R.; Osipenko, M.; Ripani, M.; Ball, J.; Konczykowski, P.

    2011-03-15

    We have measured the differential cross section for the {gamma}{sup 3}He{yields}{pi}{sup +}t reaction. This reaction was studied using the Continuous Electron Beam Accelerator Facility (CEBAF) Large Acceptance Spectrometer (CLAS) at Jefferson Lab. Real photons produced with the Hall-B bremsstrahlung tagging system in the energy range from 0.50 to 1.55 GeV were incident on a cryogenic liquid {sup 3}He target. The differential cross sections for the {gamma}{sup 3}He{yields}{pi}{sup +}t reaction were measured as a function of photon-beam energy and pion-scattering angle. Theoretical predictions to date cannot explain the large cross sections except at backward angles, showing that additional components must be added to the model.

  9. Anisotropic phases of superfluid ^{3}he in compressed aerogel.

    PubMed

    Li, J I A; Zimmerman, A M; Pollanen, J; Collett, C A; Halperin, W P

    2015-03-13

    It has been shown that the relative stabilities of various superfluid states of ^{3}He can be influenced by anisotropy in a silica aerogel framework. We prepared a suite of aerogel samples compressed up to 30% for which we performed pulsed NMR on ^{3}He imbibed within the aerogel. We identified A and B phases and determined their magnetic field-temperature phase diagrams as a function of strain. From these results, we infer that the B phase is distorted by negative strain forming an anisotropic superfluid state more stable than the A phase. PMID:25815941

  10. A Study of 3He detectors for Active Interrogation

    SciTech Connect

    E.H. Seabury; D.L. Chichester

    2009-10-01

    3He proportional counters have long been used as neutron detectors for both passive and active detection of Special Nuclear Material (SNM). The optimal configuration of these detectors as far as gas pressure, amount of moderating material, and size are concerned is highly dependent on what neutron signatures are being used to detect and identify SNM. We present here a parametric study of the neutron capture response of 3He detectors, based on Monte Carlo simulations using the MCNPX radiation transport code. The neutron capture response of the detectors has been modeled as a function of time after an incident neutron pulse.

  11. Rotational quenching of CS in ultracold 3He collisions

    NASA Astrophysics Data System (ADS)

    Kaur, Rajwant; Dhilip Kumar, T. J.

    2016-08-01

    Quantum mechanical scattering calculations of rotational quenching of CS (v = 0) collision with 3He are performed at ultracold temperatures and results are compared with isotopic 4He collision. Rotational quenching cross sections and rate coefficients have been calculated in the ultracold region for rotational levels up to j = 10 using the He-CS potential energy surface computed at the CCSD(T)/aug-cc-pVQZ level of theory. The quenching cross sections are found to be two orders of magnitude larger for the 3He than the 4He isotope under ultracold conditions. Wigner threshold law is found to be valid below 10-3 K temperature.

  12. Long-term stability of liquid ionization chambers with regard to their qualification as local reference dosimeters for low dose-rate absorbed dose measurements in water.

    PubMed

    Bahar-Gogani, J; Grindborg, J E; Johansson, B E; Wickman, G

    2001-03-01

    The long-term sensitivity and calibration stability of liquid ionization chambers (LICs) has been studied at a local and a secondary standards dosimetry laboratory over a period of 3 years. The chambers were transported several times by mail between the two laboratories for measurements. The LICs used in this work are designed for absorbed dose measurements in the dose rate region of 0.1-100 mGy min(-1) and have a liquid layer thickness of 1 mm and a sensitive volume of 16.2 mm3. The liquids used as sensitive media in the chambers are mixtures of isooctane (C8H18) and tetramethylsilane (Si(CH3)4) in different proportions (about 2 to 1). Operating at a polarizing voltage of 300 V the leakage current of the chambers was stable and never exceeded 3% of the observable current at a dose rate of about 1 mGy min(-1). The volume sensitivity of the chambers was measured to be of the order of 10(-9) C Gy(-1) mm3. No systematic changes in the absorbed dose to water calibration was observed for any of the chambers during the test period (sigma < 0.2%). Variations in chamber dose response with small changes in the polarizing voltage as well as sensitivity changes with accumulated absorbed dose were also investigated. Measurements showed that the LIC response varies by 0.15% per 1% change in applied voltage around 300 V. No significant change could be observed in the LIC sensitivity after a single absorbed dose of 15 kGy. The results indicate that the LIC can be made to serve as a calibration transfer instrument and a reference detector for absorbed dose to water determinations providing good precision and long-term reproducibility. PMID:11277221

  13. Monte Carlo simulations and benchmark measurements on the response of TE(TE) and Mg(Ar) ionization chambers in photon, electron and neutron beams

    NASA Astrophysics Data System (ADS)

    Lin, Yi-Chun; Huang, Tseng-Te; Liu, Yuan-Hao; Chen, Wei-Lin; Chen, Yen-Fu; Wu, Shu-Wei; Nievaart, Sander; Jiang, Shiang-Huei

    2015-06-01

    The paired ionization chambers (ICs) technique is commonly employed to determine neutron and photon doses in radiology or radiotherapy neutron beams, where neutron dose shows very strong dependence on the accuracy of accompanying high energy photon dose. During the dose derivation, it is an important issue to evaluate the photon and electron response functions of two commercially available ionization chambers, denoted as TE(TE) and Mg(Ar), used in our reactor based epithermal neutron beam. Nowadays, most perturbation corrections for accurate dose determination and many treatment planning systems are based on the Monte Carlo technique. We used general purposed Monte Carlo codes, MCNP5, EGSnrc, FLUKA or GEANT4 for benchmark verifications among them and carefully measured values for a precise estimation of chamber current from absorbed dose rate of cavity gas. Also, energy dependent response functions of two chambers were calculated in a parallel beam with mono-energies from 20 keV to 20 MeV photons and electrons by using the optimal simple spherical and detailed IC models. The measurements were performed in the well-defined (a) four primary M-80, M-100, M120 and M150 X-ray calibration fields, (b) primary 60Co calibration beam, (c) 6 MV and 10 MV photon, (d) 6 MeV and 18 MeV electron LINACs in hospital and (e) BNCT clinical trials neutron beam. For the TE(TE) chamber, all codes were almost identical over the whole photon energy range. In the Mg(Ar) chamber, MCNP5 showed lower response than other codes for photon energy region below 0.1 MeV and presented similar response above 0.2 MeV (agreed within 5% in the simple spherical model). With the increase of electron energy, the response difference between MCNP5 and other codes became larger in both chambers. Compared with the measured currents, MCNP5 had the difference from the measurement data within 5% for the 60Co, 6 MV, 10 MV, 6 MeV and 18 MeV LINACs beams. But for the Mg(Ar) chamber, the derivations reached 7

  14. Absolute dose measurements by means of a small cylindrical ionization chamber for very high dose per pulse high energy electron beams

    SciTech Connect

    Karaj, E.; Righi, S.; Di Martino, F.

    2007-03-15

    Very high dose per pulse (3-13 cGy/pulse) high energy electron beams are currently produced by special linear accelerators (linac) dedicated to Intra Operative Radiation Therapy (IORT). The electron beams produced by such linacs are collimated by special Perspex applicators of various size and cylindrically shaped. The biggest problems from the dosimetric point of view are caused by the high dose-per-pulse values and the use of inclined applicators. In this work measurements of absolute dose for the inclined applicators were done by using a small cylindrical ionization chamber, type CC01 (Wellhofer), a parallel plane ionization chamber type Markus (PTW 23343) and radiochromic films type EBT. We show a method which allows calculating the quality correction factors for CC01 chamber with an uncertainty of 1% and the absolute dose value for the inclined applicators using CC01 with an uncertainty of 3.1% for electron beams of energy of 6 and 7 MeV produced by the linac dedicated to IORT Novac7.

  15. Absorbed dose to water determination with ionization chamber dosimetry and calorimetry in restricted neutron, photon, proton and heavy-ion radiation fields.

    PubMed

    Brede, H J; Greif, K-D; Hecker, O; Heeg, P; Heese, J; Jones, D T L; Kluge, H; Schardt, D

    2006-08-01

    Absolute dose measurements with a transportable water calorimeter and ionization chambers were performed at a water depth of 20 mm in four different types of radiation fields, for a collimated (60)Co photon beam, for a collimated neutron beam with a fluence-averaged mean energy of 5.25 MeV, for collimated proton beams with mean energies of 36 MeV and 182 MeV at the measuring position, and for a (12)C ion beam in a scanned mode with an energy per atomic mass of 430 MeV u(-1). The ionization chambers actually used were calibrated in units of air kerma in the photon reference field of the PTB and in units of absorbed dose to water for a Farmer-type chamber at GSI. The absorbed dose to water inferred from calorimetry was compared with the dose derived from ionometry by applying the radiation-field-dependent parameters. For neutrons, the quantities of the ICRU Report 45, for protons the quantities of the ICRU Report 59 and for the (12)C ion beam, the recommended values of the International Atomic Energy Agency (IAEA) protocol (TRS 398) were applied. The mean values of the absolute absorbed dose to water obtained with these two independent methods agreed within the standard uncertainty (k = 1) of 1.8% for calorimetry and of 3.0% for ionometry for all types and energies of the radiation beams used in this comparison. PMID:16861773

  16. Minimal mass size of a stable {sup 3}He cluster

    SciTech Connect

    Guardiola, R.; Navarro, J.

    2005-03-01

    The minimal number of {sup 3}He atoms required to form a bound cluster has been estimated by means of a diffusion Monte Carlo procedure within the fixed-node approximation. Several importance sampling wave functions have been employed in order to consider different shell-model configurations. The resulting upper bound for the minimal number is 32 atoms.

  17. Probing lung microstructure with hyperpolarized 3He gradient echo MRI.

    PubMed

    Sukstanskii, Alexander L; Quirk, James D; Yablonskiy, Dmitriy A

    2014-12-01

    In this paper we demonstrate that gradient echo MRI with hyperpolarized (3)He gas can be used for simultaneously extracting in vivo information about lung ventilation properties, alveolar geometrical parameters, and blood vessel network structure. This new approach is based on multi-gradient-echo experimental measurements of hyperpolarized (3)He gas MRI signal from human lungs and a proposed theoretical model of this signal. Based on computer simulations of (3)He atoms diffusing in the acinar airway tree in the presence of an inhomogeneous magnetic field induced by the susceptibility differences between lung tissue (alveolar septa, blood vessels) and lung airspaces, we derive analytical expressions relating the time-dependent MR signal to the geometrical parameters of acinar airways and the blood vessel network. Data obtained on eight healthy volunteers are in good agreement with literature values. This information is complementary to the information obtained by means of the in vivo lung morphometry technique with hyperpolarized 3He diffusion MRI previously developed by our group, and opens new opportunities to study lung microstructure in health and disease. PMID:24920182

  18. Progress in Polarized 3He Ion Source at RCNP

    SciTech Connect

    Tanaka, M.; Takahashi, Y.; Shimoda, T.; Yasui, S.; Yosoi, M.; Takahisa, K.; Shimakura, N.; Plis, Yu. A.; Donets, E. D.

    2007-06-13

    A long history on the polarized 3He ion source developed at RCNP is presented. We started with an 'OPPIS' (Optical Pumping Polarized Ion Source) and later found the fundamental difficulties in the OPPIS. To overcome them an 'EPPIS' (Electron Pumping Polarized Ion Source) was proposed and its validity was experimentally proven. However, a serious technical disadvantage was also found in the EPPIS. To avoid this disadvantage we proposed a new concept, 'SEPIS' (Spin Exchange Polarized Ion Source), which uses an enhanced spin-exchange cross section theoretically expected at low 3He+ incident energies in the 3He+ + Rb system. Next, we describe the present status of the SEPIS development: construction of a bench test device allowing the measurements of not only the spin-exchange cross sections {sigma}se but also the electron capture cross sections {sigma}ec for the 3He+ + Rb system. The latest experimental data on {sigma}ec are presented and compared with other previous experimental data and the theoretical calculations.Finally, a design study of the SEPIS for practical use in nuclear (cyclotron) and particle physics (synchrotron) is shortly mentioned.

  19. Acoustic Spectroscopy of Superfluid 3He in Aerogel

    SciTech Connect

    Davis, J. P.; Choi, H.; Pollanen, J.; Halperin, W. P.

    2006-09-07

    We have designed an experiment to study the role of global anisotropic quasiparticle scattering on the dirty aerogel superfluid 3He system. We observe significant regions of two stable phases at temperatures below the superfluid transition at a pressure of 25 bar for a 98% aerogel.

  20. Flight performance of a rocket-borne 3He refrigerator

    NASA Astrophysics Data System (ADS)

    Duband, L.; Alsop, D.; Lange, A.; Hayata, S.; Matsumoto, T.; Sato, S.

    A self-contained, recyclable 3He refrigerator suitable for use in zero-gravity has been developed. This refrigerator successfully flew on 5 September 1989, as part of an S-520 sounding rocket payload designed to measure the spectrum of the cosmic submillimetre background. This paper presents the cryogenic performance of the refrigerator during flight.

  1. Analysis of the /sup 3/Hep. -->. pppn reaction at a momentum of /sup 3/He nuclei 5 GeV/c in the pole model

    SciTech Connect

    Abdullin, S.K.; Blinov, A.V.; Vanyushin, I.A.; Grechko, V.E.; Ergakov, V.A.; Zombkovskii, S.M.; Korolev, Y.V.; Selektor, Y.M.; Solov'ev, V.V.; Turov, V.F.; and others

    1988-01-01

    The 80-cm liquid-hydrogen bubble chamber at the Institute of Theoretical and Experimental Physics was exposed in a separated beam of /sup 3/He nuclei with momentum 5 GeV/c. On the basis of kinematic analysis 7506 /sup 3/He..-->..pppn reaction events were selected. The principal experimental distributions for this reaction were compared with the predictions of the pole model, which take into account the final-state interaction between spectators.

  2. (18)F primary standard at ENEA-INMRI by three absolute techniques and calibration of a well-type IG11 ionization chamber.

    PubMed

    Capogni, Marco; Carconi, Pierluigi; De Felice, Pierino; Fazio, Aldo

    2016-03-01

    A new (18)F primary standardization carried out at ENEA-INMRI by three different absolute techniques, i.e. 4πγNaI(Tl)γ high-efficiency counting, TDCR and 4πβ(LS)-γ[NaI(Tl)] coincidence counting method, allowed the calibration of a fixed well-reentrant IG11 ionization chamber (IC), with an uncertainty lower than 1%, and to check the calibration factor of a portable well-type IC NPL-CRC model, previously calibrated. By the new standard the ENEA-INMRI was linked to the BIPM International Reference System (SIR) through the BIPM SIR Transfer Instrument (SIRTI). PMID:26774395

  3. Instantaneous and continuous measurement of /sup 14/C-labeled substrate oxidation to /sup 14/CO2 by minute tissue specimens: an ionization chamber method

    SciTech Connect

    Davidson, W.D.; Klein, K.L.; Kurokawa, K.; Soll, A.H.

    1981-06-01

    The vibrating reed electrometer and ionization chamber have been adapted for the instantaneous and continuous measurement of /sup 14/C-labeled substrate oxidation to /sup 14/CO2 by minute quantities of isolated tissues. This modified technique, utilizing a ''closed'' circulation incubation system, is 10-50 times as sensitive as the previously described ''open'' circulation techniques. Substrate oxidation curves are described for human erythrocytes and polymorphonuclear leucocytes, canine parietal cells and isolated segments of the rat nephron. This apparatus should prove to be a useful tool for metabolic studies of small quantities of isolated tissue.

  4. Heat Capacity of Dilute 3He-4He Monolayer Films

    NASA Astrophysics Data System (ADS)

    Morishita, Masashi

    2016-05-01

    The heat capacities of a small amount of 3He dissolved in monolayer 4He films are measured to clarify natures of monolayer 4He films. With increasing areal density, the measured heat capacities gradually increase and subsequently gradually decrease. With further increase in areal density, the measured heat capacity rapidly decreases to zero over a very narrow areal density range near that of the sqrt{3} × sqrt{3} phase. These slightly complex areal-density variations and dependence on 3He concentration are discussed from the viewpoint of the known properties of 4He films. The behaviors can be explained. However, the expected two-dimensional gas-liquid or gas-solid coexistence is not observed in this study.

  5. Hexapole magnet system for thermal energy 3He atom manipulation

    NASA Astrophysics Data System (ADS)

    Jardine, A. P.; Fouquet, P.; Ellis, J.; Allison, W.

    2001-10-01

    We present design and construction details for a novel high field, small bore permanent hexapole magnet. The design is intended for focusing atomic beams of 3He at thermal energies. The magnet uses an optimized polepiece design which includes vacuum gaps to enable its use with high intensity atomic and molecular beams. The 0.3 m long, 1 mm internal radius magnet achieves a polepiece tip field of 1.1 T using NdFeB permanent magnets and Permendur 49 polepieces. The polepiece shanks are designed to saturate so that the hexapole properties are determined predominantly by the shape of the polepiece tip. The performance of the hexapole assembly is demonstrated with an 8 meV 3He beam in the beam source of the Cambridge spin echo spectrometer and the measured focused beam results show excellent agreement with theoretical predictions and negligible beam attenuation.

  6. Nuclear spin heat capacity of 3He adsorbed on graphite

    NASA Astrophysics Data System (ADS)

    Greywall, Dennis S.

    1989-10-01

    The heat capacity of 3He adsorbed on graphite has been measured for films between one and five atomic layers and for temperatures between 2 and 200 mK. These results are compared with recent magnetization data which also show several anomalies in this coverage regime. Prior to third layer promotion the second layer is found to solidify into a registered structure with unusual propertis. This contradicts the model proposed to explain the NMR measurements.

  7. NOVEL CONCEPTS FOR ISOTOPIC SEPARATION OF 3HE/4HE

    SciTech Connect

    Roy, L.; Nigg, H.; Watson, H.

    2012-09-04

    The research outlined below established theoretical proof-of-concept using ab initio calculations that {sup 3}He can be separated from {sup 4}He by taking advantage of weak van der Waals interactions with other higher molecular weight rare gases such as xenon. To the best of our knowledge, this is the only suggested method that exploits the physical differences of the isotopes using a chemical interaction.

  8. Density of liquid 3He in 8 T magnetic field

    NASA Astrophysics Data System (ADS)

    Matsumoto, Koichi; Hasegawa, Syuichi; Okuda, Yuichi

    2000-07-01

    We report a precise measurement of the density of liquid 3He in a 8 T field. Measurements performed at saturated vapour pressure between 30 and 300 mK show a field-induced increase of density. The relative change is about 1×10 -5 in this temperature range. These results are in agreement with a calculation based on a Maxwell relation and the pressure dependence of the susceptibility.

  9. Hard two-body photodisintegration of 3He.

    PubMed

    Pomerantz, I; Ilieva, Y; Gilman, R; Higinbotham, D W; Piasetzky, E; Strauch, S; Adhikari, K P; Aghasyan, M; Allada, K; Amaryan, M J; Anefalos Pereira, S; Anghinolfi, M; Baghdasaryan, H; Ball, J; Baltzell, N A; Battaglieri, M; Batourine, V; Beck, A; Beck, S; Bedlinskiy, I; Berman, B L; Biselli, A S; Boeglin, W; Bono, J; Bookwalter, C; Boiarinov, S; Briscoe, W J; Brooks, W K; Bubis, N; Burkert, V; Camsonne, A; Canan, M; Carman, D S; Celentano, A; Chandavar, S; Charles, G; Chirapatpimol, K; Cisbani, E; Cole, P L; Contalbrigo, M; Crede, V; Cusanno, F; D'Angelo, A; Daniel, A; Dashyan, N; de Jager, C W; De Vita, R; De Sanctis, E; Deur, A; Djalali, C; Dodge, G E; Doughty, D; Dupre, R; Dutta, C; Egiyan, H; El Alaoui, A; El Fassi, L; Eugenio, P; Fedotov, G; Fegan, S; Fleming, J A; Fradi, A; Garibaldi, F; Geagla, O; Gevorgyan, N; Giovanetti, K L; Girod, F X; Glister, J; Goetz, J T; Gohn, W; Golovatch, E; Gothe, R W; Griffioen, K A; Guegan, B; Guidal, M; Guo, L; Hafidi, K; Hakobyan, H; Harrison, N; Heddle, D; Hicks, K; Ho, D; Holtrop, M; Hyde, C E; Ireland, D G; Ishkhanov, B S; Isupov, E L; Jiang, X; Jo, H S; Joo, K; Katramatou, A T; Keller, D; Khandaker, M; Khetarpal, P; Khrosinkova, E; Kim, A; Kim, W; Klein, F J; Koirala, S; Kubarovsky, A; Kubarovsky, V; Kuleshov, S V; Kvaltine, N D; Lee, B; LeRose, J J; Lewis, S; Lindgren, R; Livingston, K; Lu, H Y; MacGregor, I J D; Mao, Y; Martinez, D; Mayer, M; McCullough, E; McKinnon, B; Meekins, D; Meyer, C A; Michaels, R; Mineeva, T; Mirazita, M; Moffit, B; Mokeev, V; Montgomery, R A; Moutarde, H; Munevar, E; Munoz Camacho, C; Nadel-Turonski, P; Nasseripour, R; Nepali, C S; Niccolai, S; Niculescu, G; Niculescu, I; Osipenko, M; Ostrovidov, A I; Pappalardo, L L; Paremuzyan, R; Park, K; Park, S; Petratos, G G; Phelps, E; Pisano, S; Pogorelko, O; Pozdniakov, S; Procureur, S; Protopopescu, D; Puckett, A J R; Qian, X; Qiang, Y; Ricco, G; Rimal, D; Ripani, M; Ritchie, B G; Rodriguez, I; Ron, G; Rosner, G; Rossi, P; Sabatié, F; Saha, A; Saini, M S; Sarty, A J; Sawatzky, B; Saylor, N A; Schott, D; Schulte, E; Schumacher, R A; Seder, E; Seraydaryan, H; Shneor, R; Smith, G D; Sokhan, D; Sparveris, N; Stepanyan, S S; Stepanyan, S; Stoler, P; Subedi, R; Sulkosky, V; Taiuti, M; Tang, W; Taylor, C E; Tkachenko, S; Ungaro, M; Vernarsky, B; Vineyard, M F; Voskanyan, H; Voutier, E; Walford, N K; Wang, Y; Watts, D P; Weinstein, L B; Weygand, D P; Wojtsekhowski, B; Wood, M H; Yan, X; Yao, H; Zachariou, N; Zhan, X; Zhang, J; Zhao, Z W; Zheng, X; Zonta, I

    2013-06-14

    We have measured cross sections for the γ(3)He → pd reaction at photon energies of 0.4-1.4 GeV and a center-of-mass angle of 90°. We observe dimensional scaling above 0.7 GeV at this center-of-mass angle. This is the first observation of dimensional scaling in the photodisintegration of a nucleus heavier than the deuteron. PMID:25165915

  10. Thermal Conductivity of Spin-Polarized Liquid {sup 3}He

    SciTech Connect

    Sawkey, D.; Puech, L.; Wolf, P.E.

    2006-06-02

    We present the first measurements of the thermal conductivity of spin-polarized normal liquid {sup 3}He. Using the rapid melting technique to produce nuclear polarizations up to 0.7, and a vibrating wire both as a heater and a thermometer, we show that, unlike the viscosity, the conductivity increases much less than predicted for s-wave scattering. We suggest that this might be due to a small probability for head-on collisions between quasiparticles.

  11. High Efficiency Spin Flipper for the n3He Experiment

    NASA Astrophysics Data System (ADS)

    Hayes, Christopher; n3He Collaboration

    2015-10-01

    The n3He experiment, constructed on the Fundamental Neutron Physics Beamline (FnPB) at the Spallation Neutron Source, is designed to measure the parity violating (PV) proton asymmetry Ap in the capture reaction n +3 He -->3 H + p + 765 keV The asymmetry has an estimated value Ap ~ - 1 ×10-7 and is directly related to the weak isospin conserved couplings hρ0 and ωρ0 which are of fundamental interest in the verification of the meson exchange model of low energy NN intereactions. Data production for the n3He experiment began in February 2015 and is scheduled to continue thru December 2015 - reaching a statistical sensitivity δAp ~10-8 or better. I will discuss the spin flipper which is designed using the theory of double cosine-theta coils, and capable of flipping neutron spins with an efficiency approaching its maximum value ɛsf = 1 . I will also discuss the theory of Spin Magnetic Resonance (SMR) and how it is employed by the spin flipper to flip 60 Hz pulses of cold neutrons over a range of wavelengths.

  12. Noise Studies of Polarimetry Systems for Polarized 3 He Targets

    NASA Astrophysics Data System (ADS)

    Katugampola, Sumudu K.; Matyas, Daniel J.; Nelyubin, Vladimir; Wang, Yunxiao; Cates, Gordon D.

    2015-04-01

    The NMR technique of adiabatic fast passage (AFP) plays an important role in 3 He targets polarized using spin-exchange optical pumping. Since AFP signals before amplification are generally small, identifying these signals amidst noise caused by external electromagnetic interference and micro-phonics can be challenging. When using thermally polarized water samples for absolute calibration of AFP signals, electromagnetic and micro-phonic noise can easily dominate. Although both types of interference have often been cited as the predominant sources of noise during AFP, few studies of these effects have been done under the conditions that are typical for a polarized 3 He target. This talk will describe studies of electromagnetic and micro-phonic noise using a small-scale prototype NMR system similar to those we use to study polarized 3 He targets. We will describe the effect of using aluminum metal shielding and other methods to minimize noise. We are using these studies to inform the design of a full-scale set up that will be used to test next-generation targets for use at Jefferson Lab, and measure atomic parameters relevant to polarimetry.

  13. Uranium Neutron Coincidence Collar Model Utilizing 3He

    SciTech Connect

    Siciliano, Edward R.; Rogers, Jeremy L.; Schweppe, John E.; Lintereur, Azaree T.; Kouzes, Richard T.

    2012-07-30

    The Department of Energy Office of Nuclear Safeguards (NA-241) is supporting the project 'Coincidence Counting With Boron-Based Alternative Neutron Detection Technology' at Pacific Northwest National Laboratory (PNNL) for development of an alternative neutron coincidence counter. The goal of this project is to design, build and demonstrate a boron-lined proportional tube based alternative system in a configuration typically used for 3He-based coincidence counter applications. The specific application selected for boron-lined tube replacement in this project was one of the Uranium Neutron Coincidence Collar (UNCL) designs. This report, providing results for model development of a UNCL, is a deliverable under Task 2 of the project. The current UNCL instruments utilize 3He tubes. As the first step in developing and optimizing a boron-lined proportional counter based version of the UNCL, models of eight different 3He-based UNCL detectors currently in use were developed and evaluated. A comparison was made between the simulated results and measured efficiencies for those systems with values reported in the literature. The reported experimental measurements for efficiencies and die-away times agree to within 10%.

  14. Enhancement of Magnetization in Liquid 3He at Aerogel Interface

    NASA Astrophysics Data System (ADS)

    Fukui, A.; Kondo, K.; Kato, C.; Obara, K.; Yano, H.; Ishikawa, O.; Hata, T.

    2013-05-01

    A novel feature of condensate state in liquid 3He is predicted theoretically, which consists of spin triplet s-wave Cooper pairs (Higashitani et al. in J. Low. Temp. Phys. 155:83-97, 2009). Such a spin triplet s-wave state will appear inside aerogel near the surface boundary contacting with superfluid 3He-B, and the enhancement of magnetization due to s-wave state is theoretically expected (Nagato et al. in J. Phys. Soc. Jpn. 78:123603, 2009; Higashitani et al. in Phys. Rev. B 85:024524, 2012). In order to detect this proximity effect, we made the interface in columnar glass tube which coated with 2.5 layer 4He, and set a saddle shape NMR coil very near the interface. At 7 bar, we found that superfluidity in liquid 3He inside aerogel never occurred, even at considerably low temperatures. At 24 bar below T/ T c =0.392, we observed no decrease of magnetization with decreasing temperatures. This phenomenon might be due to spin triplet s-wave Cooper pairs.

  15. Dating degassed groundwater with 3H/3He

    NASA Astrophysics Data System (ADS)

    Visser, Ate; Broers, Hans Peter; Bierkens, Marc F. P.

    2007-10-01

    The production of gases in groundwater under contaminated locations by geochemical and biological processes is not uncommon. Degassing of these gases from groundwater and repartitioning of noble gases between water and gas phase distorts groundwater dating by 3H/3He. We observed noble gas concentrations below atmospheric equilibrium in 20 out of 34 groundwater samples from agriculturally polluted sandy areas in the Netherlands. From the absence of nitrate in degassed samples, we conclude that denitrification causes degassing. The 22Ne/20Ne ratios show that degassing had attained solubility equilibrium and had not caused isotopic fractionation by diffusion. To correct for the loss of tritiogenic 3He due to degassing, we present a single-step equilibrium degassing model. We use the total dissolved gas pressure at the monitoring screen to estimate the depth and timing of degassing, which is essential to estimate travel times from degassed samples. By propagating the uncertainties in the underlying measurements and assumptions through the travel time calculations, we found a travel time uncertainty of 3 years (a). We therefore conclude that 3H/3He dating can produce valuable information on groundwater flow even at sites with strong degassing.

  16. Conception and realization of a parallel-plate free-air ionization chamber for the absolute dosimetry of an ultrasoft X-ray beam

    SciTech Connect

    Groetz, J.-E. Mavon, C.; Fromm, M.; Ounoughi, N.; Belafrites, A.

    2014-08-15

    We report the design of a millimeter-sized parallel plate free-air ionization chamber (IC) aimed at determining the absolute air kerma rate of an ultra-soft X-ray beam (E = 1.5 keV). The size of the IC was determined so that the measurement volume satisfies the condition of charged-particle equilibrium. The correction factors necessary to properly measure the absolute kerma using the IC have been established. Particular attention was given to the determination of the effective mean energy for the 1.5 keV photons using the PENELOPE code. Other correction factors were determined by means of computer simulation (COMSOL™and FLUKA). Measurements of air kerma rates under specific operating parameters of the lab-bench X-ray source have been performed at various distances from that source and compared to Monte Carlo calculations. We show that the developed ionization chamber makes it possible to determine accurate photon fluence rates in routine work and will constitute substantial time-savings for future radiobiological experiments based on the use of ultra-soft X-rays.

  17. Nuclear Ordered Phases of Solid 3He in Silver Sinters

    NASA Astrophysics Data System (ADS)

    Schuberth, Erwin A.; Kath, Matthias; Bago, Simone

    2006-09-01

    To determine the exact spin structure of the nuclear magnetic ordered phases of solid 3He, the U2D2 low field and the high field phases above 0.4 T, a European Research and Training Network for neutron scattering from the ordered solid was established which consisted of a collaboration with the Hahn Meitner Institute, Berlin, and other European and US groups. For this experiment it is crucial to grow a single crystal within the sinter needed for cooling the solid to temperatures of the order of 500 μK and to keep it cold long enough to measure a magnetic neutron diffraction. The sinter is also necessary to absorb the major part (> 90%) of the heat generated by the neutron capture and decay reaction of the 3He nucleus. In this work we studied the growth of crystals in Ag sinters of different pore sizes and with different growth speeds to find an optimal way to obtain single crystalline samples, or at least samples with only a few grains. We used SQUID magnetometry and NMR to measure the magnetization in the ordered phases. They were indicated by the known drop of the intensity, both in the NMR signal and in the dc magnetization, for the U2D2 phase, and by an increase of about 30% for the high field phase. The best results for cooling were obtained with sinters made from 700 Å "Japanese powder" with a packing fraction of 50% which were annealed at 130 °C after sintering and then had a calculated particle size of about 4200 Å. In the dc magnetization we found a paramagnetic surface contribution from a few monolayers of 3He down to 500 μK in addition to the bulk magnetization.

  18. NMR Studies of 3He Films on Boron Nitride

    NASA Astrophysics Data System (ADS)

    Tang, Y.; Sullivan, N. S.

    2014-12-01

    We report the results of NMR studies of the dynamics of 3He adsorbed on hexagonal boron nitride. These studies can identify the phase transitions of the 2D films as a function of temperature. A thermally activated temperature dependence is observed for 2.6 < T < 8 K compared to a linear temperature dependence for 0.7 < T < 2.6 K. This linear dependence is consistent with that expected for thermal diffusion in a fluid for coverages of 0.4 - 0.6 of a monolayer.

  19. 3He Spin-Dependent Cross Sections and Sum Rules

    SciTech Connect

    Slifer, Karl; Amaryan, Moscov; Amaryan, Moskov; Auerbach, Leonard; Averett, Todd; Berthot, J.; Bertin, Pierre; Bertozzi, William; Black, Tim; Brash, Edward; Brown, D.; Burtin, Etienne; Calarco, John; Cates, Gordon; Chai, Zhengwei; Chen, Jian-Ping; Choi, Seonho; Chudakov, Eugene; Ciofi, Claudio; Cisbani, Evaristo; De Jager, Cornelis; Deur, Alexandre; DiSalvo, R.; Dieterich, Sonja; Djawotho, Pibero; Finn, John; Fissum, Kevin; Fonvieille, Helene; Frullani, Salvatore; Gao, Haiyan; Gao, Juncai; Garibaldi, Franco; Gasparian, Ashot; Gilad, Shalev; Gilman, Ronald; Glamazdin, Oleksandr; Glashausser, Charles; Glockle, W.; Golak, J.; Goldberg, Emma; Gomez, Javier; Gorbenko, Viktor; Hansen, Jens-Ole; Hersman, F.; Holmes, Richard; Huber, Garth; Hughes, Emlyn; Humensky, Thomas; Incerti, Sebastien; Iodice, Mauro; Jensen, S.; Jiang, Xiaodong; Jones, C.; Jones, G.; Jones, Mark; Jutier, Christophe; Kamada, H.; Ketikyan, Armen; Kominis, Ioannis; Korsch, Wolfgang; Kramer, Kevin; Kumar, Krishna; Kumbartzki, Gerfried; Kuss, Michael; Lakuriqi, Enkeleida; Laveissiere, Geraud; LeRose, John; Liang, Meihua; Liyanage, Nilanga; Lolos, George; Malov, Sergey; Marroncle, Jacques; McCormick, Kathy; McKeown, Robert; Meziani, Zein-Eddine; Michaels, Robert; Mitchell, Joseph; Nogga, Andreas; Pace, Emanuele; Papandreou, Zisis; Pavlin, Tina; Petratos, Gerassimos; Pripstein, David; Prout, David; Ransome, Ronald; Roblin, Yves; Rowntree, David; Rvachev, Marat; Sabatie, Franck; Saha, Arunava; Salme, Giovanni; SCOPETTA, S.; Skibinski, R.; Souder, Paul; Saito, Teijiro; Strauch, Steffen; Suleiman, Riad; Takahashi, Kazunori; Todor, Luminita; Tsubota, Hiroaki; Ueno, Hiroaki; Urciuoli, Guido; van der Meer, Rob; Vernin, Pascal; Voskanyan, Hakob; Witala, Henryk; Wojtsekhowski, Bogdan; Xiong, Feng; Xu, Wang; Yang, Jae-Choon; Zhang, Bin; Zolnierczuk, Piotr

    2008-07-01

    We present a measurement of the spin-dependent cross sections for the \\vec{^3He}(\\vec{e},e')X} reaction in the quasielastic and resonance regions at four-momentum transfer 0.1 < Q^2< 0.9 GeV^2. The spin-structure functions have been extracted and used to evaluate the nuclear Burkhardt--Cottingham and extended GDH sum rules for the first time. Impulse approximation and exact three-body Faddeev calculations are also compared to the data in the quasielastic region.

  20. Hard Photodisintegration of Proton Pairs in {sup 3}He

    SciTech Connect

    Piasetzky, Eli; Pomerantz, Ishay; Higinbotham, D.; Strauch, S.; Gilman, R.

    2008-10-13

    Hard deuteron photodisintegration has been investigated for 20 years, as its cross section follows the constituent counting rule and it provides insight into the interplay between hadronic and quark-gluon degrees of freedom in high-momentum transfer exclusive reactions. We have now measured for the first time hard pp-pair disintegration in the reaction {gamma}{sup 3}He{yields}pp+n, using kinematics corresponding to a spectator neutron. Cross sections were measured for 90 deg. c.m. at 8 beam energies, from 0.8 to 4.7 GeV. Preliminary results will be presented and compared to the hard deuteron photodisintegration data.

  1. High-pressure /sup 3/He gas scintillation neutron spectrometer

    SciTech Connect

    Derzon, M.S.; Slaughter, D.R.; Prussin, S.G.

    1985-10-01

    A high-pressure, /sup 3/He-Xe gas scintillation spectrometer has been developed for neutron spectroscopy on D-D fusion plasmas. The spectrometer exhibits an energy resolution of (121 +- 20 keV) keV (FWHM) at 2.5 MeV and an efficiency of (1.9 +- 0.4) x 10/sup -3/ (n/cm/sup 2/)/sup -1/. The contribution to the resolution (FWHM) from counting statistics is only (22 +- 3 keV) and the remainder is due predominantly to the variation of light collection efficiency with location of neutron events within the active volume of the detector.

  2. Isospin effects in the exclusive dp 3He reaction

    NASA Astrophysics Data System (ADS)

    Mielke, M.; Burmeister, I.; Chiladze, D.; Dymov, S.; Fritzsch, C.; Gebel, R.; Goslawski, P.; Hartmann, M.; Kacharava, A.; Khoukaz, A.; Kulessa, P.; Lorentz, B.; Mersmann, T.; Mikirtychiants, S.; Ohm, H.; Papenbrock, M.; Rausmann, T.; Serdyuk, V.; Ströher, H.; Täschner, A.; Valdau, Yu.; Wilkin, C.

    2014-06-01

    The differential cross section for the exclusive reaction has been measured with high resolution and large statistics over a large fraction of the backward 3He hemisphere at the excess energy 265 MeV using the COSY-ANKE magnetic spectrometer. Though the well-known ABC enhancement is observed in the spectrum, the differences detected between the and invariant-mass distributions show that there must be some isospin-one production even at relatively low excess energies. The invariant-mass differences are modeled in terms of the sequential decay.

  3. Fermion Monte Carlo Calculations on Liquid-3He

    SciTech Connect

    Kalos, M H; Colletti, L; Pederiva, F

    2004-03-16

    Methods and results for calculations of the ground state energy of the bulk system of {sup 3}He atoms are discussed. Results are encouraging: they believe that they demonstrate that their methods offer a solution of the ''fermion sign problem'' and the possibility of direct computation of many-fermion systems with no uncontrolled approximations. Nevertheless, the method is still rather inefficient compared with variational or fixed-node approximate methods. There appears to be a significant populations size effect. The situation is improved by the inclusion of ''Second Stage Importance Sampling'' and of ''Acceptance/Rejection'' adapted to their needs.

  4. High-momentum response of liquid 3He.

    PubMed

    Mazzanti, F; Polls, A; Boronat, J; Casulleras, J

    2004-02-27

    A final-state-effects formalism suitable to analyze the high-momentum response of Fermi liquids is presented and used to study the dynamic structure function of liquid 3He. The theory, developed as a natural extension of the Gersch-Rodriguez formalism, incorporates the Fermi statistics explicitly through a new additive term which depends on the semidiagonal two-body density matrix. The use of a realistic momentum distribution, calculated using the diffusion Monte Carlo method, and the inclusion of this additive correction allows for good agreement with available deep-inelastic neutron scattering data. PMID:14995785

  5. Direct measurement of absorbed dose to water in HDR {sup 192}Ir brachytherapy: Water calorimetry, ionization chamber, Gafchromic film, and TG-43

    SciTech Connect

    Sarfehnia, Arman; Kawrakow, Iwan; Seuntjens, Jan

    2010-04-15

    Purpose: Gafchromic film and ionometric calibration procedures for HDR {sup 192}Ir brachytherapy sources in terms of dose rate to water are presented and the experimental results are compared to the TG-43 protocol as well as with the absolute dose measurement results from a water calorimetry-based primary standard. Methods: EBT-1 Gafchromic films, an A1SL Exradin miniature Shonka thimble type chamber, and an SI HDR 1000 Plus well-type chamber (Standard Imaging, Inc., Middleton, WI) with an ADCL traceable S{sub k} calibration coefficient (following the AAPM TG-43 protocol) were used. The Farmer chamber and Gafchromic film measurements were performed directly in water. All results were compared to direct and absolute absorbed dose to water measurements from a 4 deg. C stagnant water calorimeter. Results: Based on water calorimetry, the authors measured the dose rate to water to be 361{+-}7 {mu}Gy/(h U) at a 55 mm source-to-detector separation. The dose rate normalized to air-kerma strength for all the techniques agree with the water calorimetry results to within 0.83%. The overall 1-sigma uncertainty on water calorimetry, ionization chamber, Gafchromic film, and TG-43 dose rate measurement amounts to 1.90%, 1.44%, 1.78%, and 2.50%, respectively. Conclusions: This work allows us to build a more realistic uncertainty estimate for absorbed dose to water determination using the TG-43 protocol. Furthermore, it provides the framework necessary for a shift from indirect HDR {sup 192}Ir brachytherapy dosimetry to a more accurate, direct, and absolute measurement of absorbed dose to water.

  6. Quantum Phase Transition of 3He in Aerogel at a Nonzero Pressure

    NASA Astrophysics Data System (ADS)

    Matsumoto, K.; Porto, J. V.; Pollack, L.; Smith, E. N.; Ho, T. L.; Parpia, J. M.

    1997-07-01

    We present evidence for a nonzero pressure, T = 0 superfluid phase transition of 3He in 98.2% open aerogel. Unlike bulk 3He which is a superfluid at T = 0 at all pressures (densities) between zero and the melting pressure, 3He in aerogel is not superfluid unless the 3He density exceeds a critical value ρc. About 90% of the 3He added above ρc contributes to the superfluid density.

  7. Effective theory of 3H and 3He

    NASA Astrophysics Data System (ADS)

    König, Sebastian; Grießhammer, Harald W.; Hammer, H.-W.; van Kolck, U.

    2016-06-01

    We present a new perturbative expansion for pionless effective field theory with Coulomb interactions in which at leading order (LO) the spin-singlet nucleon–nucleon channels are taken in the unitarity limit. Presenting results up to next-to-leading order for the Phillips line and the neutron–deuteron doublet-channel phase shift, we find that a perturbative expansion in the inverse {}1{S}0 scattering lengths converges rapidly. Using a new systematic treatment of the proton–proton sector that isolates the divergence due to one-photon exchange, we renormalize the corresponding contribution to the {}3{{H}} –{}3{He} binding energy splitting and demonstrate that the Coulomb force in pionless EFT is a completely perturbative effect in the trinucleon bound-state regime. In our new expansion, the LO is exactly isospin-symmetric. At next-to-leading order, we include isospin breaking via the Coulomb force and two-body scattering lengths, and find for the energy splitting {({E}B{(}3{He})-{E}B{(}3{{H}}))}{NLO}\\quad =(-0.86+/- 0.17)\\quad {MeV}.

  8. Source investigation of impulsive 3He-rich particle events

    NASA Astrophysics Data System (ADS)

    Tan, Chengming; Yan, Yihua

    We have investigated the source characteristic and coronal magnetic field structure of six impulsive solar energetic particle (SEP) events selected from Wang et al. [Wang, Y.-M., Pick, M., Mason, G.M. Coronal holes, jets, and the origin of 3He-rich particle events. ApJ 639, 495, 2006] and Pick et al. [Pick, M., Mason, G.M., Wang, Y.-M., Tan, C., Wang, L. Solar source regions for 3He-rich solar energetic particle events identified using imaging radio, optical, and energetic particle observations. ApJ 648, 1247, 2006]. Some results are obtained: first, 2 events are associated with wide (≈100°) CMEs (hereafter wide CME events), another 4 events are associated with narrow (⩽40°) CMEs (hereafter narrow CME events); second, the coronal magnetic field configuration of narrow CME events appear more simple than that of the wide CME events; third, the photospheric magnetic field evolutions of all these events show new emergence of fluxes, while one case also shows magnetic flux cancellation; fourth, the EUV jets usually occurred very close to the footpoint of the magnetic field loop, while meter type III bursts occurred near or at the top of the loop and higher than EUV jets. Furthermore, the heights of type III bursts are estimated from the result of the coronal magnetic field extrapolations.

  9. Liquid and Solid Phases of 3He on Graphite

    NASA Astrophysics Data System (ADS)

    Gordillo, M. C.; Boronat, J.

    2016-04-01

    Recent heat-capacity experiments show quite unambiguously the existence of a liquid 3He phase adsorbed on graphite. This liquid is stable at an extremely low density, possibly one of the lowest found in nature. Previous theoretical calculations of the same system, and in strictly two dimensions, agree with the result that this liquid phase is not stable and the system is in the gas phase. We calculated the phase diagram of normal 3He adsorbed on graphite at T =0 using quantum Monte Carlo methods. Considering a fully corrugated substrate, we observe that at densities lower than 0.006 Å-2 the system is a very dilute gas that, at that density, is in equilibrium with a liquid of density 0.014 Å-2 . Our prediction matches very well the recent experimental findings on the same system. On the contrary, when a flat substrate is considered, no gas-liquid coexistence is found, in agreement with previous calculations. We also report results on the different solid structures, and on the corresponding phase transitions that appear at higher densities.

  10. The 3H-3He Charge Radii Difference

    NASA Astrophysics Data System (ADS)

    Myers, L. S.; Arrington, J. R.; Higinbotham, D. W.

    2016-03-01

    The upcoming E12-14-009 [1] experiment at Jefferson Lab will determine the ratio of the electric form factors for the A=3 mirror nuclei 3He and 3H. The measurement will use a 1.1 GeV electron beam, a special collimator plate to allow for simultaneous optics measurements, and the low-activity tritium target being prepared for Jefferson Lab. By observing the dependence of the form factor ratio as a function of Q2 over 0.05-0.09 GeV2, the dependence of the radii extraction on the shape of the form factors is minimized. As a result, we anticipate the uncertainty of the extracted charge radii difference to be 0.03 fm, a reduction of 70% from the current measurement. Using precise measurements of the 3He charge radius from isotopic shift or μHe measurements [2-4], we can deduce the absolute 3H charge radius. The results will provide a direct comparison to recent calculations of the charge radii.

  11. Double-quantum vortex in superfluid 3He-A

    PubMed

    Blaauwgeers; Eltsov; Krusius; Ruohio; Schanen; Volovik

    2000-03-30

    Linear defects are generic in continuous media. In quantum systems they appear as topological line defects which are associated with a circulating persistent current. In relativistic quantum field theories they are known as cosmic strings, in superconductors as quantized flux lines, and in superfluids and low-density Bose-Einstein condensates as quantized vortex lines. A conventional quantized vortex line consists of a central core around which the phase of the order parameter winds by 27(pi)n, while within the core the order parameter vanishes or is depleted from the bulk value. Usually vortices are singly quantized (that is, have n = 1). But it has been theoretically predicted that, in superfluid 3He-A, vortex lines are possible that have n = 2 and continuous structure, so that the orientation of the multicomponent order parameter changes smoothly throughout the vortex while the amplitude remains constant. Here we report direct proof, based on high-resolution nuclear magnetic resonance measurements, that the most common vortex line in 3He-A has n = 2. One vortex line after another is observed to form in a regular periodic process, similar to a phase-slip in the Josephson effect. PMID:10761908

  12. Hard photodisintegration of a proton pair in {sup 3}He

    SciTech Connect

    Stanley Brodsky; Leonid Frankfurt; Ronald Gilman; J. R. Hiller; G. A. Miller; Eliezer Piasetzky; Misak Sargsian; Mark Strikman

    2003-05-01

    Hard photodisintegration of the deuteron has been extensively studied in order to understand the dynamics of the transition from hadronic to quark-gluon descriptions of the strong interaction. In this work, we discuss the extension of this program to hard photodisintegration of a pp pair in the {sup 3}He nucleus. Experimental confirmation of new features predicted here for the suggested reaction would advance our understanding of hard nuclear reactions. A main prediction, in contrast with low-energy observations, is that the pp breakup cross section is not much smaller than the one for pn break up. In some models, the energy-dependent oscillations observed for pp scattering are predicted to appear in the {gamma} {sup 3}He {yields} pp + n reaction. Such an observation would open up a completely new field in studies of color coherence phenomena in hard nuclear reactions. We also demonstrate that, in addition to the energy dependence, the measurement of the light-cone momentum distribution of the recoil neutron provides an independent test of the underlying dynamics of hard disintegration.

  13. First observation of two hyperfine transitions in antiprotonic 3He

    PubMed Central

    Friedreich, S.; Barna, D.; Caspers, F.; Dax, A.; Hayano, R.S.; Hori, M.; Horváth, D.; Juhász, B.; Kobayashi, T.; Massiczek, O.; Sótér, A.; Todoroki, K.; Widmann, E.; Zmeskal, J.

    2011-01-01

    We report on the first experimental results for microwave spectroscopy of the hyperfine structure of p¯3He+. Due to the helium nuclear spin, p¯3He+ has a more complex hyperfine structure than p¯4He+, which has already been studied before. Thus a comparison between theoretical calculations and the experimental results will provide a more stringent test of the three-body quantum electrodynamics (QED) theory. Two out of four super-super-hyperfine (SSHF) transition lines of the (n,L)=(36,34) state were observed. The measured frequencies of the individual transitions are 11.12559(14) GHz and 11.15839(18) GHz, less than 1 MHz higher than the current theoretical values, but still within their estimated errors. Although the experimental uncertainty for the difference of these frequencies is still very large as compared to that of theory, its measured value agrees with theoretical calculations. This difference is crucial to be determined because it is proportional to the magnetic moment of the antiproton. PMID:21822351

  14. Textural domain walls in superfluid 3He-B

    NASA Astrophysics Data System (ADS)

    Mizushima, Takeshi

    Owing to the richness of symmetry, the superfluid 3He serves as a rich repository of topological quantum phenomena. This includes the emergence of surface Majorana fermions and their quantum mass acquisition at the topological critical point. Furthermore, the marriage of the prototype topological superfluid with nanofabrication techniques brings about a rich variety of spontaneous symmetry breaking, such as the formation of the stripe order and nontrivial domain walls. In this work, we examine the possible formation of textural domain walls in the superfluid 3He-B confined to a thin slab with a sub-micron thickness. When an applied magnetic field is much higher than the dipolar field, two nearly degenerate ground states appear, which are characterized by the Ising order associated with the spontaneous breaking of a magnetic order-two symmetry, lcirc;z = + 1 and - 1 . We here discuss the structure of the textural domain wall formed by the spatial modulation of the Ising order, such as low-lying quasiparticle excitations and spontaneous spin current. We also report bosonic modes bound to the textural domain wall.

  15. Dosimetry for electron Intra-Operative RadioTherapy: Comparison of output factors obtained through alanine/EPR pellets, ionization chamber and Monte Carlo-GEANT4 simulations for IORT mobile dedicate accelerator

    NASA Astrophysics Data System (ADS)

    Marrale, Maurizio; Longo, Anna; Russo, Giorgio; Casarino, Carlo; Candiano, Giuliana; Gallo, Salvatore; Carlino, Antonio; Brai, Maria

    2015-09-01

    In this work a comparison between the response of alanine and Markus ionization chamber was carried out for measurements of the output factors (OF) of electron beams produced by a linear accelerator used for Intra-Operative Radiation Therapy (IORT). Output factors (OF) for conventional high-energy electron beams are normally measured using ionization chamber according to international dosimetry protocols. However, the electron beams used in IORT have characteristics of dose per pulse, energy spectrum and angular distribution quite different from beams usually used in external radiotherapy, so the direct application of international dosimetry protocols may introduce additional uncertainties in dosimetric determinations. The high dose per pulse could lead to an inaccuracy in dose measurements with ionization chamber, due to overestimation of ks recombination factor. Furthermore, the electron fields obtained with IORT-dedicated applicators have a wider energy spectrum and a wider angular distribution than the conventional fields, due to the presence of electrons scattered by the applicator's wall. For this reason, a dosimetry system should be characterized by a minimum dependence from the beam energy and from angle of incidence of electrons. This become particularly critical for small and bevelled applicators. All of these reasons lead to investigate the use of detectors different from the ionization chamber for measuring the OFs. Furthermore, the complete characterization of the radiation field could be accomplished also by the use of Monte Carlo simulations which allows to obtain detailed information on dose distributions. In this work we compare the output factors obtained by means of alanine dosimeters and Markus ionization chamber. The comparison is completed by the Monte Carlo calculations of OFs determined through the use of the Geant4 application "iort _ therapy" . The results are characterized by a good agreement of response of alanine pellets and Markus

  16. Studies of 3He polarization losses during NMR and EPR measurment and Polarized 3He target cell lifetime

    NASA Astrophysics Data System (ADS)

    An, Peibo

    2014-09-01

    The 3He target cell polarized by spin-exchange optical pumping(SEOP) is used as a neutron substitute to study the inner structure of the neutron. In our lab, nuclear-magnetic-resonance(NMR) is used to measure the relative polarization and electron-paramagnetic-resonance(EPR) is used to measure the spin exchange EPR frequency shift parameter of potassium and rubidium in our target cell presented in magnetic fields. The alkali in the cell is used to facilitate the polarization of 3He. The first part of my work presents the study of the polarization losses of the cell during both NMR and EPR. With the help of improved RF coils, we keep the background noise received by pickup coils reasonably low, but three other kinds of losses are inevitable: losses during Adiabatic Fast Passage (AFP) sweep, losses due to flux change caused by different cell orientation with respect to RF fields and physical losses. Fortunately there is only flux change in NMR measurements. The second part of my work presents the study of cell lifetime improvement. The polarization decreases in a process called relaxation exponentially. The lifetime of a cell is how long it can keep its polarization. The typical lifetime of cells produced in our lab is about 22 hours. With a newly designed vacuum system. The 3He target cell polarized by spin-exchange optical pumping(SEOP) is used as a neutron substitute to study the inner structure of the neutron. In our lab, nuclear-magnetic-resonance(NMR) is used to measure the relative polarization and electron-paramagnetic-resonance(EPR) is used to measure the spin exchange EPR frequency shift parameter of potassium and rubidium in our target cell presented in magnetic fields. The alkali in the cell is used to facilitate the polarization of 3He. The first part of my work presents the study of the polarization losses of the cell during both NMR and EPR. With the help of improved RF coils, we keep the background noise received by pickup coils reasonably low, but

  17. Dependence of charge collection distributions and dose on the gas type filling the ionization chamber for a p(66)Be(49) clinical neutron beam

    SciTech Connect

    Awschalom, M.; Haken, R.K.T.

    1985-01-01

    Measurements of central axis depth charge distributions (CADCD) in a p(66)Be(49) clinical neutron beam using A-150 TE plastic ionization chambers (IC) have shown that these distributions are dependent on the gas type filling the ICs. IC volumes from 0.1 to 8 cm/sup 3/ and nine different gases were investigated. Off axis ratios and build-up measurements do not seem to be as sensitive to gas type. The gas dosimetry constants given in the AAPM Protocol for Neutron Beam Dosimetry for air and methane based TE gases were tested for consistency in water and in TE solution filled phantoms at depths of 10 cm, when used in conjunction with an IC having 5 mm thick walls of A-150. 29 refs., 7 figs., 1 tab.

  18. Comparison of dosimeter response: ionization chamber, TLD, and Gafchromic EBT2 film in 3D-CRT, IMRT, and SBRT techniques for lung cancer

    NASA Astrophysics Data System (ADS)

    Fitriandini, A.; Wibowo, W. E.; Pawiro, S. A.

    2016-03-01

    This research was conducted by measuring point dose in the target area (lungs), heart, and spine using four dosimeters (PTW N30013, Exradin A16, TLD, and the Gafchromic EBT2 film). The measurement was performed in CIRS 002LFC thorax phantom. The main objective of this study was to compare the dosimetry of those different systems. Dose measurements performed only in a single fraction of irradiation. The measurements result shown that TLD has the least accuracy and precision. As the effect of volume averaging, ionization chamber reaches the discrepancy value up to -13.30% in the target area. EBT2 film has discrepancy value of <1% in the 3D-CRT and IMRT techniques. This dosimeter is proposed to be an appropriate alternative dosimeter to be used at point dose verification.

  19. The FiR 1 photon beam model adjustment according to in-air spectrum measurements with the Mg(Ar) ionization chamber.

    PubMed

    Koivunoro, H; Schmitz, T; Hippeläinen, E; Liu, Y-H; Serén, T; Kotiluoto, P; Auterinen, I; Savolainen, S

    2014-06-01

    The mixed neutron-photon beam of FiR 1 reactor is used for boron-neutron capture therapy (BNCT) in Finland. A beam model has been defined for patient treatment planning and dosimetric calculations. The neutron beam model has been validated with an activation foil measurements. The photon beam model has not been thoroughly validated against measurements, due to the fact that the beam photon dose rate is low, at most only 2% of the total weighted patient dose at FiR 1. However, improvement of the photon dose detection accuracy is worthwhile, since the beam photon dose is of concern in the beam dosimetry. In this study, we have performed ionization chamber measurements with multiple build-up caps of different thickness to adjust the calculated photon spectrum of a FiR 1 beam model. PMID:24588987

  20. Characterization of radiation beams used to determinate the correction factor for a CyberKnife® unit reference field using ionization chambers

    NASA Astrophysics Data System (ADS)

    Aragón-Martínez, Nestor; Gómez-Muñoz, Arnulfo; Massillon-JL, Guerda

    2014-11-01

    This paper aimed to characterize a 6 MV x-ray beam from a Varian® iX linear accelerator in order to obtain the correction factors needed by the IAEA/AAPM new formalism1. The experiments were performed in a liquid water phantom under different irradiation conditions: a) Calibration of the reference field of 10 cm × 10 cm at 90 cm SSD and 10 cm depth was carried out according to the TRS-398 protocol using three ionization chambers (IC) calibrated in different reference laboratory and b) Measurement of the absorbed dose rate at 70 cm SSD and 10 cm depth in a 10 cm × 10 cm and 5.4 cm × 5.4 cm fields was obtained in order to simulate the CyberKnife® conditions where maximum distance between the source and the detector is equal to 80 cm and the maximum field size is 6 cm diameter. Depending where the IC was calibrated, differences between 0.16% and 2.24% in the absorbed dose rate measured in the 10 cm × 10 cm field at 90 cm SSD were observed, while for the measurements at 70 cm SSD, differences between 1.27% and 3.88% were obtained. For the 5.4 cm × 5.4 cm field, the absorbed dose measured with the three ICs varies between 1.37% and 3.52%. The increase in the difference on the absorbed dose when decreasing the SSD could possibly be associated to scattering radiation generated from the collimators and/or the energy dependence of the ionization chambers to low-energy radiation. The results presented in this work suggest the importance of simulating the CyberKnife® conditions using other linear accelerator for obtaining the correction factors as proposed by the IAEA/AAPM new formalism in order to measure the absorbed dose with acceptable accuracy.

  1. Characterization of radiation beams used to determinate the correction factor for a CyberKnife® unit reference field using ionization chambers

    SciTech Connect

    Aragón-Martínez, Nestor Massillon-JL, Guerda; Gómez-Muñoz, Arnulfo

    2014-11-07

    This paper aimed to characterize a 6 MV x-ray beam from a Varian® iX linear accelerator in order to obtain the correction factors needed by the IAEA/AAPM new formalism{sup 1}. The experiments were performed in a liquid water phantom under different irradiation conditions: a) Calibration of the reference field of 10 cm × 10 cm at 90 cm SSD and 10 cm depth was carried out according to the TRS-398 protocol using three ionization chambers (IC) calibrated in different reference laboratory and b) Measurement of the absorbed dose rate at 70 cm SSD and 10 cm depth in a 10 cm × 10 cm and 5.4 cm × 5.4 cm fields was obtained in order to simulate the CyberKnife® conditions where maximum distance between the source and the detector is equal to 80 cm and the maximum field size is 6 cm diameter. Depending where the IC was calibrated, differences between 0.16% and 2.24% in the absorbed dose rate measured in the 10 cm × 10 cm field at 90 cm SSD were observed, while for the measurements at 70 cm SSD, differences between 1.27% and 3.88% were obtained. For the 5.4 cm × 5.4 cm field, the absorbed dose measured with the three ICs varies between 1.37% and 3.52%. The increase in the difference on the absorbed dose when decreasing the SSD could possibly be associated to scattering radiation generated from the collimators and/or the energy dependence of the ionization chambers to low-energy radiation. The results presented in this work suggest the importance of simulating the CyberKnife® conditions using other linear accelerator for obtaining the correction factors as proposed by the IAEA/AAPM new formalism in order to measure the absorbed dose with acceptable accuracy.

  2. A dynamic model for power deposition in 3He lasers pumped by 3He(n,p) 3H reactions

    NASA Astrophysics Data System (ADS)

    Çetin, Füsun

    2004-07-01

    The coupled variation of power density with gas density in a nuclear-pumped laser, which is excited by 3He(n,p) 3H reaction products, is considered. In the literature, volumetric excitation by reaction products of 3He(n,p) 3H is only considered for the case in which gas density is uniform and does not change during the pumping. In this work, a time-dependent model describing the coupled fluid dynamic and particle transport behaviour of the gas has been developed. In modelling charge particle transport behaviour, a previously reported energy deposition model for a constant gas density is extended for a variable gas density by taking into account variations in the particle range, macroscopic cross sections and neutron flux depending on density field of the gas. The coupled equations, which are obtained by using the power deposition density expression obtained for variable gas density in the acoustically filtered equations of motion of the gas, are solved numerically. Spatial and temporal variations of power deposition density and gas density during the pumping pulse are determined for various operating pressures ranging from 0.5 to 10 atm. In the calculations, the characteristics of I.T.U TRIGA Mark-II Reactor are used and it is assumed that laser tube is placed in the centre of the reactor core. Obtained results are presented and examined.

  3. Reference dosimetry at the Australian Synchrotron's imaging and medical beamline using free-air ionization chamber measurements and theoretical predictions of air kerma rate and half value layer

    SciTech Connect

    Crosbie, Jeffrey C.; Rogers, Peter A. W.; Stevenson, Andrew W.; Hall, Christopher J.; Lye, Jessica E.; Nordstroem, Terese; Midgley, Stewart M.; Lewis, Robert A.

    2013-06-15

    Purpose: Novel, preclinical radiotherapy modalities are being developed at synchrotrons around the world, most notably stereotactic synchrotron radiation therapy and microbeam radiotherapy at the European Synchrotron Radiation Facility in Grenoble, France. The imaging and medical beamline (IMBL) at the Australian Synchrotron has recently become available for preclinical radiotherapy and imaging research with clinical trials, a distinct possibility in the coming years. The aim of this present study was to accurately characterize the synchrotron-generated x-ray beam for the purposes of air kerma-based absolute dosimetry. Methods: The authors used a theoretical model of the energy spectrum from the wiggler source and validated this model by comparing the transmission through copper absorbers (0.1-3.0 mm) against real measurements conducted at the beamline. The authors used a low energy free air ionization chamber (LEFAC) from the Australian Radiation Protection and Nuclear Safety Agency and a commercially available free air chamber (ADC-105) for the measurements. The dimensions of these two chambers are different from one another requiring careful consideration of correction factors. Results: Measured and calculated half value layer (HVL) and air kerma rates differed by less than 3% for the LEFAC when the ion chamber readings were corrected for electron energy loss and ion recombination. The agreement between measured and predicted air kerma rates was less satisfactory for the ADC-105 chamber, however. The LEFAC and ADC measurements produced a first half value layer of 0.405 {+-} 0.015 and 0.412 {+-} 0.016 mm Cu, respectively, compared to the theoretical prediction of 0.427 {+-} 0.012 mm Cu. The theoretical model based upon a spectrum calculator derived a mean beam energy of 61.4 keV with a first half value layer of approximately 30 mm in water. Conclusions: The authors showed in this study their ability to verify the predicted air kerma rate and x-ray attenuation

  4. {sup 3}He target for Hall C at CEBAF

    SciTech Connect

    Zeidman, B.; Zeuli, A.

    1995-08-01

    A major fraction of the physics program for Hall C involves scattering from cryogenic targets of the lightest nuclei, i.e. H, D, and {sup 3,4}He. Argonne is constructing the He target that will consist of a 4cm cylinder, operating at a pressure of 10 atmospheres and a temperature of {approximately}5.2 degrees Kelvin. CEBAF is currently constructing a cryo-target system for liquid H and D cells and the cooled, pressurized helium targets. The He target system includes cell loop, the He supply systems, and the additional equipment needed to ensure minimum loss of {sup 3}He in the event of target rupture. Some of the major components have been completed, while the balance of the system will be ready for installation this fiscal year.

  5. Event identification in 3He proportional counters using risetime discrimination

    NASA Astrophysics Data System (ADS)

    Langford, T. J.; Bass, C. D.; Beise, E. J.; Breuer, H.; Erwin, D. K.; Heimbach, C. R.; Nico, J. S.

    2013-07-01

    We present a straightforward method for particle identification and background rejection in 3He proportional counters for use in neutron detection. By measuring the risetime and pulse height of the preamplifier signals, one may define a region in the risetime versus pulse height space where the events are predominately from neutron interactions. For six proportional counters surveyed in a low-background environment, we demonstrate the ability to reject alpha-particle events with an efficiency of 99%. By applying the same method, we also show an effective rejection of microdischarge noise events that, when passed through a shaping amplifier, are indistinguishable from physical events in the counters. The primary application of this method is in measurements where the signal-to-background for counting neutrons is very low, such as in underground laboratories.

  6. Direct energy conversion system for D(3)-He fusion

    NASA Astrophysics Data System (ADS)

    Tomita, Y.; Shu, L. Y.; Momota, H.

    1993-11-01

    A novel and highly efficient direct energy conversion system is proposed for utilizing D(3)-He fueled fusion. In order to convert kinetic energy of ions, we applied a pair of direct energy conversion systems each of which has a cusp-type DEC and a traveling wave DEC (TWDEC). In a cusp-type DEC, electrons are separated from the escaping ions at the first line-cusp and the energy of thermal ion components is converted at the second cusp DEC. The fusion protons go through the cusp-type DEC and arrive at the TWDEC, which principle is similar to 'LINAC'. The energy of fusion protons is recovered to electricity with an efficiency of more than 70%. These DEC's bring about the high efficient fusion plant.

  7. Polarimetries for the Polarized 3 He Target at JLab

    NASA Astrophysics Data System (ADS)

    Ton, Nguyen; Jefferson Lab Polarized 3 He Target Collaboration

    2015-04-01

    At Jefferson Lab, a Polarized 3 He Target has been used as an effective polarized neutron target for studying nucleon spin structure. For the 12 GeV program at JLab, the first stage upgrade of the target aim to increase luminosity by a factor of 2 (to luminosity ~ 2 ×1036 cm-2s-1) while keep maximum in-beam polarization at 60 % with 30 μA beam current and reach a systematic uncertainty of polarimetry below 3 %. During the 6 GeV era, the target polarization was measured by two polarimetries: adiabatic fast passage-nuclear magnetic resonance (AFP-NMR) and electron paramagnetic resonance (EPR). With the upgrade, a new polarimetry, Pulse-NMR, is being studied in the lab for the up-coming metal coated target. In this talk, we will discuss the detail study of AFP-NMR, EPR, Pulsed-NMR measurements and their corresponding uncertainties.

  8. Electrodisintegration of 3He below and above deuteron breakup threshold

    SciTech Connect

    Marcucci, L. E.; Viviani, M.; Schiavilla, R.; Kievsky, A.; Rosati, S.

    2005-02-01

    Recent advances in the study of electrodisintegration of 3He are presented and discussed. The pair-correlated hyperspherical harmonics method is used to calculate the initial and final state wave functions, with a realistic Hamiltonian consisting of the Argonne v18 two-nucleon and Urbana IX three-nucleon interactions. The model for the nuclear current and charge operators retains one- and many-body contributions. Particular attention is made in the construction of the two-body current operators arising from the momentum-dependent part of the two-nucleon interaction. Three-body current operators are also included so that the full current operator is strictly conserved. The present model for the nuclear current operator is tested comparing theoretical predictions and experimental data of pd radiative capture cross section and spin observables.

  9. Perspectives of hyperpolarized noble gas MRI beyond 3He

    PubMed Central

    Lilburn, David M.L.; Pavlovskaya, Galina E.; Meersmann, Thomas

    2013-01-01

    Nuclear Magnetic Resonance (NMR) studies with hyperpolarized (hp) noble gases are at an exciting interface between physics, chemistry, materials science and biomedical sciences. This paper intends to provide a brief overview and outlook of magnetic resonance imaging (MRI) with hp noble gases other than hp 3He. A particular focus are the many intriguing experiments with 129Xe, some of which have already matured to useful MRI protocols, while others display high potential for future MRI applications. Quite naturally for MRI applications the major usage so far has been for biomedical research but perspectives for engineering and materials science studies are also provided. In addition, the prospects for surface sensitive contrast with hp 83Kr MRI is discussed. PMID:23290627

  10. Stability of superfluid 3He-B in compressed aerogel.

    PubMed

    Li, J I A; Zimmerman, A M; Pollanen, J; Collett, C A; Gannon, W J; Halperin, W P

    2014-03-21

    In recent work, it was shown that new anisotropic p-wave states of superfluid (3)He can be stabilized within high-porosity silica aerogel under uniform positive strain. In contrast, the equilibrium phase in an unstrained aerogel is the isotropic superfluid B phase. Here we report that this phase stability depends on the sign of the strain. For a negative strain of ∼ 20% achieved by compression, the B phase can be made more stable than the anisotropic A phase, resulting in a tricritical point for A, B, and normal phases with a critical field of ∼ 100 mT. From pulsed NMR measurements, we identify these phases and the orientation of the angular momentum. PMID:24702386

  11. APT {sup 3}He target/blanket. Topical report

    SciTech Connect

    1995-03-01

    The {sup 3}He target/blanket (T/B) preconceptual design for the 3/8-Goal facility is based on a 1000-MeV, 200-mA accelerator to produce a high-intensity proton beam that is expanded and then strikes one of two T/B modules. Each module consists of a centralized neutron source made of tungsten and lead, a proton beam backstop region made of zirconium and lead, and a moderator made of D{sub 2}O. Helium-3 gas is circulated through the neutron source region and the blanket to create tritium through neutron capture. The gas is continually processed to extract the tritium with an online separation process.

  12. The spectra of mixed 3He-4He droplets.

    PubMed

    Fantoni, S; Guardiola, R; Navarro, J; Zuker, A

    2005-08-01

    The diffusion Monte Carlo technique is used to calculate and analyze the excitation spectrum of 3He atoms bound to a cluster of 4He atoms by using a previously determined optimum filling of single-fermion orbits with well-defined orbital angular momentum L, spin S, and parity quantum numbers. The study concentrates on the energies and shapes of the three kinds of states for which the fermionic part of the wave function is a single Slater determinant: maximum L or maximum S states within a given orbit, and fully polarized clusters. The picture that emerges is that of systems with strong shell effects, whose binding and excitation energies are essentially determined by averages over configuration at fixed number of particles and spin, i.e., by the monopole properties of an effective Hamiltonian. PMID:16108665

  13. Measurements of miniature ionization chamber currents in the JSI TRIGA Mark II reactor demonstrate the importance of the delayed contribution to the photon field in nuclear reactors

    NASA Astrophysics Data System (ADS)

    Radulović, Vladimir; Fourmentel, Damien; Barbot, Loïc; Villard, Jean-François; Kaiba, Tanja; Gašper, Žerovnik; Snoj, Luka

    2015-12-01

    The characterization of experimental locations of a research nuclear reactor implies the determination of neutron and photon flux levels within, with the best achievable accuracy. In nuclear reactors, photon fluxes are commonly calculated by Monte Carlo simulations but rarely measured on-line. In this context, experiments were conducted with a miniature gas ionization chamber (MIC) based on miniature fission chamber mechanical parts, recently developed by the CEA (French Atomic Energy and Alternative Energies Commission) irradiated in the core of the Jožef Stefan Institute TRIGA Mark II reactor in Ljubljana, Slovenia. The aim of the study was to compare the measured MIC currents with calculated currents based on simulations with the MCNP6 code. A discrepancy of around 50% was observed between the measured and the calculated currents; in the latter taking into consideration only the prompt photon field. Further experimental measurements of MIC currents following reactor SCRAMs (reactor shutdown with rapid insertions of control rods) provide evidence that over 30% of the total measured signal is due to the delayed photon field, originating from fission and activation products, which are untreated in the calculations. In the comparison between the measured and calculated values, these findings imply an overall discrepancy of less than 20% of the total signal which is still unexplained.

  14. Derivation of a formula describing the saturation correction of plane-parallel ionization chambers in pulsed fields with arbitrary repetition rate

    NASA Astrophysics Data System (ADS)

    Karsch, Leonhard

    2016-04-01

    Gas-filled ionization chambers are widely used radiation detectors in radiotherapy. A quantitative description and correction of the recombination effects exists for two cases, for continuous radiation exposure and for pulsed radiation fields with short single pulses. This work gives a derivation of a formula for pulsed beams with arbitrary pulse rate for which the prerequisites of the two existing descriptions are not fulfilled. Furthermore, an extension of the validity of the two known cases is investigated. The temporal evolution of idealized charge density distributions within a plane parallel chamber volume is described for pulsed beams of vanishing pulse duration and arbitrary pulse repetition rate. First, the radiation induced release, movement and collection of the charge carriers without recombination are considered. Then, charge recombination is calculated basing on these simplified charge distributions and the time dependent spatial overlap of positive and negative charge carrier distributions. Finally, a formula for the calculation of the saturation correction factor is derived by calculation and simplification of the first two terms of a Taylor expansion for small recombination. The new formula of saturation correction contains the two existing cases, descriptions for exposure by single pulses and continuous irradiation, as limiting cases. Furthermore, it is possible to determine the pulse rate range for which each of the three descriptions is applicable by comparing the dependencies of the new formula with the two existing cases. As long as the time between two pulses is lower than one third of the collection time of the chamber, the formalism for a continuous exposure can be used. The known description for single pulse irradiation is only valid if the repetition rate is less than 1.2 times the inverse collection time. For all other repetition rates in between the new formula should be used. The experimental determination by Jaffe diagrams can be

  15. Homolytic Reactive Mass Spectrometry of Fullerenes: Peculiarities of the Reactions of C60 with Aromatic Compounds in the Ionization Chambers of Mass Spectrometers and in Solution

    NASA Astrophysics Data System (ADS)

    Lyakhovetsky, Yury I.; Shilova, Elena A.; Belokon, Alexander I.; Panz, Larisa I.; Tumanskii, Boris L.

    2013-04-01

    C60 reacted with PhH, PhCl, BnH, BnNH2, and o-C2H2B10H10 in the electron impact (EI) ion source of a mass spectrometer at 300 °C forming phenyl, benzyl, and o-carboranyl adducts, respectively, stabilized by hydrogen addition and loss. Besides, the additions to C60 of methyl and phenyl radicals for toluene, and a phenyl radical for benzylamine were observed. A homolytic reaction mechanism was suggested involving the reaction of the radicals formed from the aromatics under EI with C60 at the ionization chamber walls. While the ion/molecule reaction of C60 with benzene performed by Sun et al. under chemical ionization conditions at 200 °C afforded the complex C60•PhH+•, quite a different isomer, HC60Ph+•, was detected in the present study as a sequence of the different reaction mechanisms. C60 also reacted with benzyl bromide in the laser desorption/ionization (LDI) source of a mass spectrometer to give C60CPh+. Phenyl and benzyl derivatives of C60 were found, respectively, when the reactions of the fullerene with PhCl, BnH, and BnBr were performed in solution under ultra violet irradiation. For the reaction with toluene, the strong chemically induced dynamic electron polarization of the intermediate benzylfullerenyl radical with the reverse phase effect was found. The coincidence of the results of the mass spectrometry and solution reactions of C60 with aromatics, even though incomplete, additionally supports the hypothesis, formulated earlier, that the former results can predict the latter ones to a significant extent and shows that this conclusion is valid for both EI and LDI initiated reactions in mass spectrometers.

  16. Assaying multiple 125I seeds with the well-ionization chamber SourceCheck4π 33005 and a new insert

    PubMed Central

    Ballester, Facundo; Perez-Calatayud, Jose; Vijande, Javier

    2015-01-01

    Purpose To provide a practical solution that can be adopted in clinical routine to fulfill the AAPM-ESTRO recommendations regarding quality assurance of seeds used in prostate permanent brachytherapy. The aim is to design a new insert for the well-ionization chamber SourceCheck4π 33005 (PTW, Germany) that allows evaluating the mean air-kerma strength of up to ten 125I seeds with one single measurement instead of measuring each seed individually. Material and methods The material required is: a) the SourceCheck4π 33005 well-ionization chamber provided with a PTW insert to measure the air-kerma strength S K of one single seed at a time; b) a newly designed insert that accommodates ten seeds in one column, which allows measuring the mean S K of the ten seeds in one single measurement; and c) a container with ten seeds from the same batch and class of the seeds used for the patient implant, and a set of nine non-radioactive seeds. The new insert is characterized by determining its calibration coefficient, used to convert the reading of the well-chamber when ten seeds are measured to their mean S K. The proposed method is validated by comparing the mean S K of the ten seeds obtained from the new insert with the individual measurement of S K of each seed, evaluated with the PTW insert. Results The ratio between the calibration coefficient of the new insert and the calibration coefficient of the PTW insert for the SourceCheck4π 33005 is 1.135 ± 0.007 (k = 1). The mean S K of a set of ten seeds evaluated with this new system is in agreement with the mean value obtained from measuring independently the S K of each seed. Conclusions The new insert and procedure allow evaluating the mean S K of ten seeds prior to the implant in a single measurement. The method is faster and more efficient from radiation protection point of view than measuring the individual S K of each seed. PMID:26816507

  17. Exploration of kinetic and multiple-ion-fluids effects in D3He and T3He gas-filled ICF implosions using multiple nuclear reaction histories

    NASA Astrophysics Data System (ADS)

    Sio, Hong; Rinderknecht, Hans; Rosenberg, Michael; Zylstra, Alex; Séguin, Fredrick; Gatu Johnson, Maria; Li, Chikang; Petrasso, Richard; Hoffman, Nelson; Kagan, Krigory; Molvig, Kim; Amendt, Peter; Bellei, Claudio; Wilks, Scott; Stoeckl, Christian; Glebov, Vladimir; Betti, Riccardo; Sangster, Thomas; Katz, Joseph

    2014-10-01

    To explore kinetic and multi-ion-fluid effects in D3He and T3He gas-filled shock-driven implosions, multiple nuclear reaction histories were measured using the upgraded Particle Temporal Diagnostic (PTD) on OMEGA. For D3He gas-filled implosions, the relative timing of the DD and D3He reaction histories were measured with 20 ps precision. For T3He gas-filled implosions (with 1-2% deuterium), the relative timing of the DT and D3He reaction histories were measured with 10 ps precision. The observed differences between the reaction histories on these two OMEGA experiments are contrasted to 1-D single-ion hydro simulations for different gas-fill pressure and gas mixture. This work is supported in part by the U.S. DOE, LLNL, LLE, and NNSA SSGF.

  18. Are high 3He/4He ratios in oceanic basalts an indicator of deep-mantle plume components?

    USGS Publications Warehouse

    Meibom, A.; Anderson, D.L.; Sleep, N.H.; Frei, R.; Chamberlain, C.P.; Hren, M.T.; Wooden, J.L.

    2003-01-01

    The existence of a primordial, undegassed lower mantle reservoir characterized by high concentration of 3He and high 3He/4He ratios is a cornerstone assumption in modern geochemistry. It has become standard practice to interpret high 3He/4He ratios in oceanic basalts as a signature of deep-rooted plumes. The unfiltered He isotope data set for oceanic spreading centers displays a wide, nearly Gaussian, distribution qualitatively similar to the Os isotope (187Os/188 Os) distribution of mantle-derived Os-rich alloys. We propose that both distributions are produced by shallow mantle processes involving mixing between different proportions of recycled, variably aged radiogenic and unradiogenic domains under varying degrees of partial melting. In the case of the Re-Os isotopic system, radiogenic mid-ocean ridge basalt (MORB)-rich and unradiogenic (depleted mantle residue) endmembers are constantly produced during partial melting events. In the case of the (U+Th)-He isotope system, effective capture of He-rich bubbles during growth of phenocryst olivine in crystallizing magma chambers provides one mechanism for 'freezing in' unradiogenic (i.e. high 3He/4He) He isotope ratios, while the higher than chondritic (U+Th)/He elemental ratio in the evolving and partially degassed MORB melt provides the radiogenic (i.e. low 3He/4He) endmember. If this scenario is correct, the use of He isotopic signatures as a fingerprint of plume components in oceanic basalts is not justified. Published by Elsevier Science B.V.

  19. Neutron Multiplicity Measurements With 3He Alternative: Straw Neutron Detectors

    DOE PAGESBeta

    Mukhopadhyay, Sanjoy; Wolff, Ronald S.; Meade, John A.; Detweiler, Ryan; Maurer, Richard J.; Mitchell, Stephen E.; Guss, Paul P.; Lacy, Jeffrey L.; Sun, Liang; Athanasiades, Athanasios

    2015-01-27

    Counting neutrons emitted by special nuclear material (SNM) and differentiating them from the background neutrons of various origins is the most effective passive means of detecting SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment are complex due to the presence of high-multiplicity spallation neutrons (commonly known as “ship effect”) and to the complicated nature of the neutron scattering in that environment. In this study, a prototype neutron detector was built using 10B as the converter in a special form factor called “straws” that would address the above problems by looking into the details of multiplicity distributions ofmore » neutrons originating from a fissioning source. This paper describes the straw neutron multiplicity counter (NMC) and assesses the performance with those of a commercially available fission meter. The prototype straw neutron detector provides a large-area, efficient, lightweight, more granular (than fission meter) neutron-responsive detection surface (to facilitate imaging) to enhance the ease of application of fission meters. Presented here are the results of preliminary investigations, modeling, and engineering considerations leading to the construction of this prototype. This design is capable of multiplicity and Feynman variance measurements. This prototype may lead to a near-term solution to the crisis that has arisen from the global scarcity of 3He by offering a viable alternative to fission meters. This paper describes the work performed during a 2-year site-directed research and development (SDRD) project that incorporated straw detectors for neutron multiplicity counting. The NMC is a two-panel detector system. We used 10B (in the form of enriched boron carbide: 10B4C) for neutron detection instead of 3He. In the first year, the project worked with a panel of straw neutron detectors, investigated its characteristics, and developed a data acquisition (DAQ) system to collect

  20. Neutron multiplicity ,easurements With 3He alternative: Straw neutron detectors

    DOE PAGESBeta

    Mukhopadhyay, Sanjoy; Wolff, Ronald S.; Meade, John A.; Detweiler, Ryan; Maurer, Richard J.; Mitchell, Stephen E.; Guss, Paul P.; Lacy, Jeffrey L.; Sun, Liang; Athanasiades, Athanasios

    2015-01-27

    Counting neutrons emitted by special nuclear material (SNM) and differentiating them from the background neutrons of various origins is the most effective passive means of detecting SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment are complex due to the presence of high-multiplicity spallation neutrons (commonly known as “ship effect”) and to the complicated nature of the neutron scattering in that environment. In this study, a prototype neutron detector was built using 10B as the converter in a special form factor called “straws” that would address the above problems by looking into the details of multiplicity distributions ofmore » neutrons originating from a fissioning source. This paper describes the straw neutron multiplicity counter (NMC) and assesses the performance with those of a commercially available fission meter. The prototype straw neutron detector provides a large-area, efficient, lightweight, more granular (than fission meter) neutron-responsive detection surface (to facilitate imaging) to enhance the ease of application of fission meters. Presented here are the results of preliminary investigations, modeling, and engineering considerations leading to the construction of this prototype. This design is capable of multiplicity and Feynman variance measurements. This prototype may lead to a near-term solution to the crisis that has arisen from the global scarcity of 3He by offering a viable alternative to fission meters. This paper describes the work performed during a 2-year site-directed research and development (SDRD) project that incorporated straw detectors for neutron multiplicity counting. The NMC is a two-panel detector system. We used 10B (in the form of enriched boron carbide: 10B4C) for neutron detection instead of 3He. In the first year, the project worked with a panel of straw neutron detectors, investigated its characteristics, and developed a data acquisition (DAQ) system to collect

  1. Comment on "Deep mixing of 3He: reconciling Big Bang and stellar nucleosynthesis".

    PubMed

    Balser, Dana S; Rood, Robert T; Bania, T M

    2007-08-31

    Eggleton et al. (Reports, 8 December 2006, p. 1580) reported on a deep-mixing mechanism in low-mass stars caused by a Rayleigh-Taylor instability that destroys all of the helium isotope 3He produced during the star's lifetime. Observations of 3He in planetary nebulae, however, indicate that some stars produce prodigious amounts of 3He. This is inconsistent with the claim that all low-mass stars should destroy 3He. PMID:17761865

  2. Equilibrium helical order in radially confined superfluid 3He

    NASA Astrophysics Data System (ADS)

    Wiman, Joshua; Sauls, J. A.

    An exciting prediction of confined superfluid 3He is the presence of spontaneously broken translational symmetry, resulting in a superfluid phase that has a different translational symmetry than that of the confining geometry. Such phases have been described theoretically in films, cylinders, and ribbons. We predict an inhomogeneous superfluid phase with helical order that is energetically stable within cylindrical channels of radius comparable to the Cooper pair coherence length. By incorporating extensions to standard Ginzburg-Landau (GL) strong-coupling theory that accurately reproduce the bulk phase diagram at high pressures and allow tuneable boundary conditions, we find this new phase to be stable at both high and low pressures and favored by boundary conditions with strong pairbreaking. We present superfluid phase diagrams as functions of pressure, temperature, and channel radius showing the regions of stability for this ``spiral'' phase relative to those phases previously predicted for the channel. Transverse NMR frequency shifts are a possible experimental signature of this phase, and we present calculations of these shifts as functions of rf pulse tipping angle, field orientation, and temperature. Supported by NSF Grant DMR-1508730.

  3. Hydrogen trapping in 3He-irradiated Fe

    NASA Astrophysics Data System (ADS)

    Takagi, Ikuji; Matsuoka, Kotaro; Tanaka, Toshiyuki; Akiyoshi, Masafumi; Sasaki, Takayuki

    2013-11-01

    The characteristics of irradiation-induced hydrogen (deuterium) traps in pure Fe were investigated for quantitative evaluation of tritium retention in fusion reactor components. The deuterium depth profiles of an Fe disk sample exposed to deuterium plasma were observed by means of nuclear reaction analysis (NRA) before and after irradiation with 0.8 MeV or 1.3 MeV 3He ions. Irradiation generated a number of traps, and deuterium retention was drastically increased subsequent to irradiation. Steady-state deuterium concentration in the trap and the solution sites were obtained by continuously charging the sample with deuterium during the NRA. Based on these values, the trapping energy, which is the enthalpy difference between the two sites, was estimated to be 0.38 eV. The number ratio of the trap to atomic displacement was 0.013. Some of the traps were annihilated around 523 K. The annihilation temperature, the trapping energy, and the equilibrium constant suggest that the trap is a dislocation loop introduced by the irradiation. It is deduced that the tritium inventory in the Fe components of a reactor should be drastically increased by neutron irradiation due to the formation of traps, but may be significantly reduced by high temperature operation of the components.

  4. Andreev reflection in rotating superfluid {sup 3}He-B

    SciTech Connect

    Eltsov, V. B.; Hosio, J. J.; Krusius, M. Mäkinen, J. T.

    2014-12-15

    Andreev reflection of quasiparticle excitations from quantized line vortices is reviewed in the isotropic B phase of superfluid {sup 3}He in the temperature regime of ballistic quasiparticle transport at T ≤ 0.20T{sub c}. The reflection from an array of rectilinear vortices in solid-body rotation is measured with a quasiparticle beam illuminating the array mainly in the orientation along the rotation axis. The result is in agreement with the calculated Andreev reflection. The Andreev signal is also used to analyze the spin-down of the superfluid component after a sudden impulsive stop of rotation from an equilibrium vortex state. In a measuring setup where the rotating cylinder has a rough bottom surface, annihilation of the vortices proceeds via a leading rapid turbulent burst followed by a trailing slow laminar decay, from which the mutual friction dissipation can be determined. In contrast to the currently accepted theory, it is found to have a finite value in the zero-temperature limit: α(T→0) = (5 ± 0.5) × 10{sup −4}.

  5. Optical interferometry in superfluid {sup 3}He-B

    SciTech Connect

    Alles, H.; Ruutu, J.P.; Babkin, A.V.; Hakonen, P.J.; Sonin, E.B.

    1996-03-01

    The authors report interferometric measurements in 0.1...1 mm thick films of superfluid {sup 3}He-B. The menisci of three different rotational states of the superfluid were observed and analyzed theoretically using two-fluid hydrodynamics: These are (i) the equilibrium vortex state in which the superfluid and the normal components corotate (solid body rotation), (ii) the vortex-free state (the Landau state), in which only the normal component rotates, and (iii) the quasistationary vortex state in which only the superfluid fraction rotates (pure superfluid rotation). The Landua state manifested itself by a reduced parabolic meniscus at rotation speeds below the critical angular velocity {Omega}{sub c}{approx_lt} 0.2 rad/s for vortex formation. Transition from the Landua state to the equilibrium vortex state yielded a sudden deepening of the meniscus when {Omega}{sub c} was exceeded. After a rapid halt of the cryostat, the authors observed a novel meniscus which was produced by the superfluid rotation while the normal component was at rest. The enhanced depth of this meniscus is governed by the reactive mutual friction parameter B{prime}. By employing laser light, both for imaging and for thermomechanical excitation, the authors measured the response of a thin superfluid layer to a heat pulse and analyzed it within the theory of two fluid hydrodynamics. The data were employed, using the dispersion relation for thin film oscillations, to deduce the second viscosity coefficient {zeta}{sub 3} close to T{sub c}.

  6. Temporal Variability in the Accretion Rate of Interplanetary Dust Using (3)He as a Tracer

    NASA Technical Reports Server (NTRS)

    Farley, K. A.

    2005-01-01

    The research supported by this grant falls under three topics: 1) Weekly Interplanetary Dust Sampling via (3)He; 2) Extraterrestrial (3)He at Major Impact Boundaries; 3) Completing a Moderately-High Resolution Record of Extraterrestrial (3)He Flux: A Major Asteroidal Break up Event at 8.2 Ma.

  7. Transfer Excitation Processes Observed in N3+-He and O3+-He Collisions at Elab = 33 eV

    NASA Astrophysics Data System (ADS)

    Itoh, Yoh

    2016-09-01

    We measured the relative state-selective differential cross sections (DCSs) for one-electron capture reactions using a crossed-beam apparatus. The scattering angle θlab studied in the laboratory frame ranged from -3.0 to 22° and the laboratory collision energy Elab was 33 eV. Only the transfer excitation processes, i.e., the electron capture reactions with the simultaneous excitation of the projectile, were observed. The DCSs were determined for the following reactions: N3+ (1s2 2s2 1S) + He (1s2 1S) → N2+ (1s2 2s2p2 2D) + He+ (1s 2S) + 10.3 eV, O3+ (1s2 2s2 2p 2P) + He (1s2 1S) → O2+ (1s2 2s 2p3 3P) + He+ (1s 2S) + 12.7 eV, and O3+ (1s2 2s2 2p 2P) + He (1s2 1S) → O2+ (1s2 2s 2p3 3D) + He+ (1s 2S) + 15.5 eV. In the N3+-He system, the DCSs for the reaction are zero at the center-of-mass angle θcm = 0 and show a peak at a certain angle and a shoulder at a larger angle. In the O3+-He system, the DCSs are again zero at θcm = 0. The capture process to the O2+ (1s2 2s 2p3 3P) state is mainly observed at smaller scattering angles, and the reaction to the O2+ (1s2 2s 2p3 3D) state becomes dominant with increasing scattering angle. A classical trajectory analysis within the two-state approximation based on the ab initio potentials for (NHe)3+ revealed that the transfer excitation of a two-electron process takes place through a single crossing of the relevant potentials.

  8. Electron screening and stellar rates in the {sup 3}He({sup 3}He,2p){sup 4}He and {sup 3}He(d,p){sup 4}He fusion reactions

    SciTech Connect

    Messahel, L.; Ouichaoui, S.; Belhout, A.; Fouka, M.; Trabelsi, A.

    2008-05-12

    The astrophysical S(E) factor experimental data available over the energy region E (C.M.)<1.0 MeV for the {sup 3}He({sup 3}He,2p){sup 4}He and {sup 3}He(d,p){sup 4}He fusion reactions are analyzed using a polynomial expression and the R-Matrix formalism, respectively. The reaction thermonuclear rates for bare nuclei are determined and compared to previous ones after a precise assessment of the electron screening factors. New level parameter values are deduced for the {sup 5}Li nucleus.

  9. Elastic and quasielastic /sup 3/Hep-scattering at a /sup 3/He-momentum 2. 5 GeV/c

    SciTech Connect

    Blinov, A.V.; Vanyushin, I.A.; Grechko, V.E.; Drobot, V.V.; Ergakov, V.A.; Zombkovskii, S.M.; Kondratyuk, L.A.; Korolev, Y.V.; Selektor, Y.M.; Solov'ev, V.V.

    1985-07-01

    The differential cross sections for /sup 3/Hep elastic and quasielastic scattering and the mean energy loss of fast protons in the reaction p+/sup 3/He..-->..p/sub F/+X are obtained using the ITEP 80-cm liquid hydrogen bubble chamber, exposed to a /sup 3/He beam at momentum 2.5 GeV/c (the primary-proton kinetic energy in the rest frame of the nucleus is T/sub p/ = 0.318 GeV). The data are compared with the Glauber-Sitenko multiple-scattering-theory predictions.

  10. The development of new devices for accurate radiation dose measurement: A guarded liquid ionization chamber and an electron sealed water calorimeter

    NASA Astrophysics Data System (ADS)

    Stewart, Kristin J.

    In this work we developed two new devices that aim to improve the accuracy of relative and reference dosimetry for radiation therapy: a guarded liquid ionization chamber (GLIC) and an electron sealed water (ESW) calorimeter. With the GLIC we aimed to develop a perturbation-free energy-independent detector with high spatial resolution for relative dosimetry. We achieved sufficient stability for short-term measurements using the GLIC-03, which has a sensitive volume of approximately 2 mm3. We evaluated ion recombination in pulsed photon beams using a theoretical model and also determined a new empirical method to correct for relative differences in general recombination which could be used in cases where the theoretical model was not applicable. The energy dependence of the GLIC-03 was 1.1% between 6 and 18 MV photon beams. Measurements in the build-up region of an 18 MV beam indicated that this detector produces minimal perturbation to the radiation field and confirmed the validity of the empirical recombination correction. The ESW calorimeter was designed to directly measure absorbed dose to water in clinical electron beams. We obtained reproducible measurements for 6 to 20 MeV beams. We determined corrections for perturbations to the radiation field caused by the glass calorimeter vessel and for conductive heat transfer due to the dose gradient and non-water materials. The overall uncertainty on the ESW calorimeter dose was 0.5% for the 9 to 20 MeV beams and 1.0% for 6 MeV, showing for the first time that the development of a water-calorimeter-based standard for electron beams over a wide range of energies is feasible. Comparison between measurements with the ESW calorimeter and the NRC photon beam standard calorimeter in a 6 MeV beam revealed a discrepancy of 0.7+/-0.2% which is still under investigation. Absorbed-dose beam quality conversion factors in electron beams were measured using the ESW calorimeter for the Exradin A12 and PTW Roos ionization chambers

  11. Nonlinear development of strong current-driven instabilities and selective acceleration of ^3He ions

    NASA Astrophysics Data System (ADS)

    Toida, Mieko; Okumura, Hayato

    2003-10-01

    In some solar flares, the abundance of high-energy ^3He ions is extremely increased. As a mechanism for these ^3He rich events, current-driven instabilities are believed to be important. Nonlinear development of the strong current-driven instabilities and associated energy transfer to ^3He ions are studied theoretically and numerically [1]. First, by means of a two-dimensional, electrostatic, particle simulation code, it is demonstrated that ^3He ions are selectively accelerated by fundamental H cyclotron waves with frequencies ω ≃ 2Ω_3He (Ω_3He is the cyclotron frequency of ^3He). Then, from the analysis of the dispersion relation of these waves, it is found that the ω ≃ 2 Ω_ 3He waves have the greatest growth rate, if Te > 10 T_H. Energies of the ^3He ions are also discussed. Theoretical expression for the maximum ^3He energy is presented, which is in good agreement with the simulation results. Based on this theory, it is shown that when the initial electron drift energy is of the order of 10 keV, many ^3He ions can be accelerated to energies of the order of MeV/n. [1] M. Toida and H. Okumura, J. Phys. Soc. Jpn. 72,1098 (2003)

  12. Lattice Relaxation of 4He with 3He Impurities: NMR Studies

    NASA Astrophysics Data System (ADS)

    Candela, D.; Huan, C.; Kim, S. S.; Yin, L.; Xia, J. S.; Sullivan, N. S.

    2014-12-01

    Measurements of the 3He nuclear spin relaxation times of dilute 3He impurities in solid 4He have been used to explore the unusual dynamics of solid 4He at low temperatures. The 3He impurities move through the lattice by quantum mechanical exchange with neighboring 4He atoms. Because of the larger zero point motion of the 3He atoms, there is an appreciable lattice distortion that accompanies the tunneling 3 He atom and the tunneling motion depends on the elastic properties of the 4He lattice. This motion modulates the 3He-3He nuclear dipole- dipole interactions and thus determines the NMR relaxation rates. We compare the observed temperature dependence of the NMR relaxation rates with that expected from the measurements of the shear modulus by Syshchenko et al. [Phys. Rev. Lett. 104, 195301 (2009)].

  13. Comparison of the response of a NaI scintillation crystal with a pressurized ionization chamber as a function of altitude, radiation level and Ra-226 concentration

    SciTech Connect

    Provencher, R.; Smith, G.; Borak, T.B.; Kearney, P.

    1986-01-01

    The Grand Junction Uranium Mill Tailings Remedial Action-Radiological Survey Activities Group (UMTRA-RASA) program employs a screening method in which external exposure rates are used to determine if a property contaminated with uranium mill tailings is eligible for remedial action. Portable NaI detectors are used by survey technicians to locate contaminated areas and determine exposure rates. The exposure rate is calculated using a regression equation derived from paired measurements made with a pressurized ionization chamber (PIC) and a NaI detector. During July of 1985 extensive measurements were taken using a PIC and a NaI scintillator with both analogue and digital readout for a wide range of exposure rates and at a variety of elevations. The surface soil was sampled at most of these locations and analyzed for /sup 226/Ra. The response of the NaI detectors was shown to be highly correlated to radiation level but not to /sup 226/Ra concentration or elevation.

  14. Low-temperature instability of uniform spin precession in the B phase of pure {sup 3}He and {sup 3}He in an aerogel

    SciTech Connect

    Surovtsev, E. V. Fomin, I. A.

    2010-08-15

    The magnetic-field dependences of the threshold temperature of the low-temperature instability of uniform spin precession in pure {sup 3}He-B and {sup 3}He-B in an aerogel have been determined for the bulk mechanism. These dependences appear to be different. The theoretical dependence of the threshold temperature for the pure case has been compared with the experimental dependence. The threshold temperature of the instability for {sup 3}He in the aerogel has been estimated for typical experimental conditions.

  15. Transport in ultradilute solutions of 3He in superfluid 4He

    NASA Astrophysics Data System (ADS)

    Baym, Gordon; Beck, D. H.; Pethick, C. J.

    2015-07-01

    We calculate the effect of a heat current on transporting 3He dissolved in superfluid 4He at ultralow concentration, as will be utilized in a proposed experimental search for the electric dipole moment of the neutron (nEDM). In this experiment, a phonon wind will be generated to drive (partly depolarized) 3He down a long pipe. In the regime of 3He concentrations ≲10-9 and temperatures ˜0.5 K, the phonons comprising the heat current are kept in a flowing local equilibrium by small angle phonon-phonon scattering, while they transfer momentum to the walls via the 4He first viscosity. On the other hand, the phonon wind drives the 3He out of local equilibrium via phonon-3He scattering. For temperatures below 0.5 K, both the phonon and 3He mean free paths can reach the centimeter scale, and we calculate the effects on the transport coefficients. We derive the relevant transport coefficients, the phonon thermal conductivity, and the 3He diffusion constants from the Boltzmann equation. We calculate the effect of scattering from the walls of the pipe and show that it may be characterized by the average distance from points inside the pipe to the walls. The temporal evolution of the spatial distribution of the 3He atoms is determined by the time dependent 3He diffusion equation, which describes the competition between advection by the phonon wind and 3He diffusion. As a consequence of the thermal diffusivity being small compared with the 3He diffusivity, the scale height of the final 3He distribution is much smaller than that of the temperature gradient. We present exact solutions of the time dependent temperature and 3He distributions in terms of a complete set of normal modes.

  16. Three chamber negative ion source

    DOEpatents

    Leung, Ka-Ngo; Ehlers, Kenneth W.; Hiskes, John R.

    1985-01-01

    A negative ion vessel is divided into an excitation chamber, a negative ionization chamber and an extraction chamber by two magnetic filters. Input means introduces neutral molecules into a first chamber where a first electron discharge means vibrationally excites the molecules which migrate to a second chamber. In the second chamber a second electron discharge means ionizes the molecules, producing negative ions which are extracted into or by a third chamber. A first magnetic filter prevents high energy electrons from entering the negative ionization chamber from the excitation chamber. A second magnetic filter prevents high energy electrons from entering the extraction chamber from the negative ionizing chamber. An extraction grid at the end of the negative ion vessel attracts negative ions into the third chamber and accelerates them. Another grid, located adjacent to the extraction grid, carries a small positive voltage in order to inhibit positive ions from migrating into the extraction chamber and contour the plasma potential. Additional electrons can be suppressed from the output flux using ExB forces provided by magnetic field means and the extractor grid electric potential.

  17. A possible in situ 3H and 3He source in Earth's interior: an alternative explanation of origin of 3He in deep Earth.

    PubMed

    Jiang, Songsheng; Liu, Jing; He, Ming

    2010-07-01

    Origin of (3)He in the Earth is a mystery. Lacking a production mechanism, scientists assume (3)He was trapped in the Earth, when the Earth was formed. In contrast to this assumption, we have found (3)He and (3)H concentrations in excess of the atmospheric values in the deep waters of the volcanic Lakes Pavin (France), Laacher (Germany) and Nemrut (Turkey). This paper reports the result of finding (3)H in these three volcanic lakes that appear to originate from the mantle. Because (3)H has a half-life of 12.3 years, this (3)H and the resulting (3)He must have formed recently in the mantle and not be part of a primordial reservoir. The nuclear reactions that generate tritium might be a source of "missing" energy in the interior of the Earth. PMID:20502855

  18. Development of D+3He Fusion Electric Thrusters and Power Supplies for Space

    NASA Astrophysics Data System (ADS)

    Morse, Thomas M.

    1994-07-01

    Development of D+3He Fusion Electric Thrusters (FET) and Power Supplies (FPS) should occur at a lunar base because of the following: availability of helium-3, a vacuum better than on Earth, low K in shade reachable by radiant cooling, supply of ``high temp'' superconducting ceramic-metals, and a low G environment. The early FET will be much smaller than an Apollo engine, with specific impulse of 10,000-100,000-s. Solar power and low G will aid early development. To counter the effect of low G on humans, centrifuges will be employed for sleeping and resting. Work will be done by telerobotic view control. The FPS will be of comparable size, and will generate power mainly by having replaceable rectennas, resonant to the fusion synchrotron radiation. FPSs are used for house keeping power and initiating superconduction. Spaceships will carry up to ten FETs and two FPSs. In addition to fusion fuel, the FET will inject H or Li low mass propellant into the fusion chamber. Developing an FET would be difficult on Earth. FET spaceships will park between missions in L1, and an FET Bus will fetch humans/supplies from Moon and Earth. Someday FETs, with rocket assist, will lift spaceships from Earth, and make space travel to planets far cheaper, faster, and safer, than at present. Too long a delay due to the space station, or the huge cost of getting into space by current means, will damage the morale of the space program.

  19. Polarized {sup 3}He gas compression system using metastability-exchange optical pumping

    SciTech Connect

    Hussey, D.S.; Rich, D.R.; Belov, A.S.; Tong, X.; Yang, H.; Bailey, C.; Keith, C.D.; Hartfield, J.; Hall, G.D.R.; Black, T.C.; Snow, W.M.; Gentile, T.R.; Chen, W.C.; Jones, G.L.; Wildman, E.

    2005-05-15

    Dense samples (10-100 bar cm) of nuclear spin polarized {sup 3}He are utilized in high energy physics, neutron scattering, atomic physics, and magnetic resonance imaging. Metastability exchange optical pumping can rapidly produce high {sup 3}He polarizations ({approx_equal}80%) at low pressures (few mbar). We describe a polarized {sup 3}He gas compressor system which accepts 0.26 bar l h{sup -1} of {sup 3}He gas polarized to 70% by a 4 W neodymium doped lanthanum magnesium hexaluminate (Nd:LMA) laser and compresses it into a 5 bar cm target with final polarization of 55%. The spin relaxation rates of the system's components have been measured using nuclear magnetic resonance and a model of the {sup 3}He polarization loss based on the measured relaxation rates and the gas flow is in agreement with a {sup 3}He polarization measurement using neutron transmission.

  20. A 3He Cryostat for Scientific Measurements in Pulsed High Magnetic Fields

    NASA Astrophysics Data System (ADS)

    Wang, Shaoliang; Li, Liang; Liu, Mengyu; Zuo, Huakun; Peng, Tao

    A top loading 3He cryostat has been developed for scientific experiments with a 60 T pulsed magnetic field facility at Wuhan National High Magnetic Field Center. The cryostat consists of a 4He bath cryostat, a 3He insert and a closed circulation system for 3He gas handling. To eliminate the eddy current heating during the pulse, the tail of the 3He insert with a vacuum space at the bottom is made from fiberglass tubing coated with epoxy. The 3He bath is separated from the 4He bath with the vacuum space. The 4He bath cryostat provides cooling power to condense 3He gas by a neck tube on top of the tail. Experimental results have shown that the sample can be cooled down to 385 mK and kept cold for more than 150 second by one-shot cooling, which is sufficiently long for an experiment in a pulsed high magnetic field.

  1. Fabrication and tests of 3He and 2H targets for beam polarization measurement

    PubMed

    Naqvi; Aksoy; Nagadi; Al-Ohali; Kidwai; Fageeha

    2000-09-01

    3He and 2H targets were fabricated through implantation of 3He and 2H ions in 0.2-0.3 mm thick tantalum and titanium foils. The energy of 3He and 2H ions was 45-100 and 78 keV, respectively. Ions beams with typical current of 90-300 microA were used for implantation. Stability tests of 3He and 2H targets were carried out by monitoring the yield of 3He(d, p)4He and 2H(d, p)3H reactions. For the 3He target, the reaction yield was stable for both tantalum and titanium foils but the most stabilized maximum yield was observed for the 100 keV tantalum target. In the case of 2H targets, the yield increased with increasing total dose implanted on the target. PMID:10972150

  2. The 3He long-counter TETRA at the ALTO ISOL facility

    NASA Astrophysics Data System (ADS)

    Testov, D.; Verney, D.; Roussière, B.; Bettane, J.; Didierjean, F.; Flanagan, K.; Franchoo, S.; Ibrahim, F.; Kuznetsova, E.; Li, R.; Marsh, B.; Matea, I.; Penionzhkevich, Yu.; Pai, H.; Smirnov, V.; Sokol, E.; Stefan, I.; Suzuki, D.; Wilson, J. N.

    2016-04-01

    A new β-decay station (BEDO) has been installed behind the PARRNe mass separator operated on-line at the electron-driven ALTO ISOL facility. The station is equipped with a movable tape collector allowing the creation of the radioactive sources of interest at the very center of a modular detection system. The mechanical structure was designed to host various assemblies of detectors in compact geometry. We report here the first on-line use of this system equipped with the 4π 3He neutron counter TETRA built at JINR Dubna associated with HPGe and plastic 4π β detectors. The single neutron detection efficiency achieved is 53(2)% measured using the 252Cf source. For β-delayed neutron measurements the neutron detection efficiency was derived from the comparison of gated γ-spectra. The on-line commissioning of the TETRA setup was performed with laser-ionized gallium beams. β and neutron events were recorded as a function of time. From these data we report P1n(82Ga)=22(2)% and T1/2(82Ga)=0.604(11) s in good agreement with values available in the literature. The new detection system will be used in other experiments aimed at investigations of β-decay properties of neutron-rich isotopes produced at ALTO.

  3. Polarization of 3He by Spin Exchange with Optically Pumped Rb and K Vapors

    NASA Astrophysics Data System (ADS)

    Ben-Amar Baranga, A.; Appelt, S.; Romalis, M. V.; Erickson, C. J.; Young, A. R.; Cates, G. D.; Happer, W.

    1998-03-01

    We report on extensive experimental measurements of the key rates that determine the efficiency for polarizing the nuclei of 3He by spin exchange with optically pumped Rb vapor. In agreement with recent theoretical predictions, we find a strong temperature dependence of the electron-spin loss rates due to 3HeRb collisions. We also find that the maximum possible efficiency for spin-exchange polarization of 3He by K is 10 times greater than for Rb.

  4. NMR Studies of Texture in the B-like Phase of 3He in Aerogel

    SciTech Connect

    Dmitriev, V. V.; Zavjalov, V. V.; Zmeev, D. E.; Mulders, N.

    2006-09-07

    Continuous wave NMR experiments have been performed in the B-like phase of 3He in a 98% open aerogel. The results allow us to get information about the texture of the 3He order parameter inside the aerogel. We conclude that in the B-like phase the boundary between the bulk 3He and the aerogel orients the vector of orbital anisotropy (L) parallel to it. Two stable textures and textural transition between them were observed in our sample.

  5. Characterization of 2 MeV, 4 MeV, 6 MeV and 18 MeV buildup caps for use with a 0.6 cubic centimeter thimble ionization chamber

    SciTech Connect

    Salyer, R.L.; VanDenburg, J.W.; Prinja, A.K.; Kirby, T.; Busch, R.; Hong-Nian Jow

    1996-07-01

    The purpose of this research is to characterize existing 2 MeV, 4 MeV and 6 MeV buildup caps, and to determine if a buildup cap can be made for the 0.6 cm{sup 3} thimble ionization chamber that will accurately measure exposures in a high-energy photon radiation field. Two different radiation transport codes were used to computationally characterize existing 2 MeV, 4 MeV, and 6 MeV buildup caps for a 0.6 cm{sup 3} active volume thimble ionization chamber: ITS, The Integrated TIGER Series of Coupled Electron-Photon Monte Carlo Transport Codes; and CEPXS/ONEDANT, A One-Dimensional Coupled Electron-Photon Discrete Ordinates Code Package. These codes were also used to determine the design characteristics of a buildup cap for use in the 18 MeV photon beam produced by the 14 TW pulsed power HERMES-III electron accelerator. The maximum range of the secondary electron, the depth at which maximum dose occurs, and the point where dose and collision kerma are equal have been determined to establish the validity of electronic equilibrium. The ionization chamber with the appropriate buildup cap was then subjected to a 4 MeV and a 6 MeV bremmstrahlung radiation spectrum to determine the detector response.

  6. Chemistry of α-pinene and naphthalene oxidation products generated in a Potential Aerosol Mass (PAM) chamber as measured by acetate chemical ionization mass spectrometry

    DOE PAGESBeta

    Chhabra, P. S.; Lambe, A. T.; Canagaratna, M. R.; Stark, H.; Jayne, J. T.; Onasch, T. B.; Davidovits, P.; Kimmel, J. R.; Worsnop, D. R.

    2014-07-01

    Recent developments in high resolution, time-of-flight chemical ionization mass spectrometry (HR-ToF-CIMS) have made possible the direct detection of atmospheric organic compounds in real-time with high sensitivity and with little or no fragmentation, including low volatility, highly oxygenated organic vapors that are precursors to secondary organic aerosol formation. Here, for the first time, we examine gas-phase O3 and OH oxidation products of α-pinene and naphthalene formed in the PAM flow reactor with an HR-ToF-CIMS using acetate reagent ion chemistry. Integrated OH exposures ranged from 1.2 × 1011 to 9.7 × 1011 molec cm−3 s, corresponding to approximately 1.0 to 7.5 daysmore » of equivalent atmospheric oxidation. Measured gas-phase organic acids are similar to those previously observed in environmental chamber studies. For both precursors, we find that acetate-CIMS spectra capture both functionalization (oxygen addition) and fragmentation (carbon loss) as a function of OH exposure. The level of fragmentation is observed to increase with increased oxidation. We present a method that estimates vapor pressures of organic molecules using the measured O/C ratio, H/C ratio, and carbon number for each compound detected by the CIMS. The predicted condensed-phase SOA average acid yields and O/C and H/C ratios agree within uncertainties with previous AMS measurements and ambient CIMS results. While acetate reagent ion chemistry is used to selectively measure organic acids, in principle this method can be applied to additional reagent ion chemistries depending on the application.« less

  7. The effect of a compression paddle on energy response, calibration and measurement with mammographic dosimeters using ionization chambers and solid-state detectors

    NASA Astrophysics Data System (ADS)

    Hourdakis, C. J.; Boziari, A.; Koumbouli, E.

    2009-02-01

    A compression paddle is always used in mammography x-ray examinations, in order to improve image quality and reduce patient doses. Although clinical dose measurements should be performed with the paddle to interfere with the x-ray beam, calibration of mammography dosimeters is performed free in air without the presence of the paddle. The paddle hardens the x-ray beam, which has an impact on a dosimeter performance, particularly on high-energy-dependent detectors. Due to the paddle, clinical mammography x-ray systems may exhibit beams with HVL values exceeding those of the IEC 61267 RQR-M series qualities at which dosimeters are usually calibrated. In this study, the influence of the paddle in mammography dosimetry is examined, in Mo/Mo anode/filter x-ray qualities. PMMA slabs of 1, 2 and 3 mm thickness and Al foils of 0.05, 0.10 and 0.15 mm thicknesses were used to simulate the paddles, producing beams with HVL values from 0.28 up to 0.43 mmAl. In these qualities, four solid-state (ST) detectors and three ionizations chambers (IC) were calibrated in terms of Kair and NK and kQ were deduced. The results showed that all IC and two modern-type ST dosimeters have a flat energy response in the above HVL range (less than 3%), so their calibration factor at RQR-M2 quality could be safely used for clinical measurements. Two other ST dosimeters exhibit up to 20% energy response, so differences up to 15% in dose measurement may be observed if the effect of paddle on their performance is ignored. Finally, the need of additional mammographic calibration qualities to the existing IEC 61267 RQR-M series is examined and discussed.

  8. The effect of a compression paddle on energy response, calibration and measurement with mammographic dosimeters using ionization chambers and solid-state detectors.

    PubMed

    Hourdakis, C J; Boziari, A; Koumbouli, E

    2009-02-21

    A compression paddle is always used in mammography x-ray examinations, in order to improve image quality and reduce patient doses. Although clinical dose measurements should be performed with the paddle to interfere with the x-ray beam, calibration of mammography dosimeters is performed free in air without the presence of the paddle. The paddle hardens the x-ray beam, which has an impact on a dosimeter performance, particularly on high-energy-dependent detectors. Due to the paddle, clinical mammography x-ray systems may exhibit beams with HVL values exceeding those of the IEC 61267 RQR-M series qualities at which dosimeters are usually calibrated. In this study, the influence of the paddle in mammography dosimetry is examined, in Mo/Mo anode/filter x-ray qualities. PMMA slabs of 1, 2 and 3 mm thickness and Al foils of 0.05, 0.10 and 0.15 mm thicknesses were used to simulate the paddles, producing beams with HVL values from 0.28 up to 0.43 mmAl. In these qualities, four solid-state (ST) detectors and three ionizations chambers (IC) were calibrated in terms of Kair and N(K) and k(Q) were deduced. The results showed that all IC and two modern-type ST dosimeters have a flat energy response in the above HVL range (less than 3%), so their calibration factor at RQR-M2 quality could be safely used for clinical measurements. Two other ST dosimeters exhibit up to 20% energy response, so differences up to 15% in dose measurement may be observed if the effect of paddle on their performance is ignored. Finally, the need of additional mammographic calibration qualities to the existing IEC 61267 RQR-M series is examined and discussed. PMID:19168939

  9. Isobar separation of 93Zr and 93Nb at 24 MeV with a new multi-anode ionization chamber

    NASA Astrophysics Data System (ADS)

    Martschini, Martin; Buchriegler, Josef; Collon, Philippe; Kutschera, Walter; Lachner, Johannes; Lu, Wenting; Priller, Alfred; Steier, Peter; Golser, Robin

    2015-10-01

    93Zr with a half-life of 1.6 Ma is produced with high yield in nuclear fission, and thus should be present as a natural or anthropogenic trace isotope in all compartments of the general environment. Sensitive measurements of this isotope would immediately find numerous applications, however, its detection at sufficiently low levels has not yet been achieved. AMS measurements of 93Zr suffer from the interference of the stable isobar 93Nb. At the Vienna Environmental Research Accelerator VERA a new multi-anode ionization chamber was built. It is optimized for isobar separation in the medium mass range and is based on the experience from AMS experiments of 36Cl at our 3-MV tandem accelerator facility. The design provides high flexibility in anode configuration and detector geometry. After validating the excellent energy resolution of the detector with 36S, it was recently used to study iron-nickel and zirconium-niobium-molybdenum isobar separation. To our surprise, the separation of 94Zr (Z = 40) from 94Mo (Z = 42) was found to be much better than that of 58Fe (Z = 26) from 58Ni (Z = 28), despite the significantly larger ΔZ/Z of the latter pair. This clearly contradicts results from SRIM-simulations and suggests that differences in the stopping behavior may unexpectedly favor identification of 93Zr. At 24 MeV particle energy, a 93Nb (Z = 41) suppression factor of 1000 is expected based on a synthetic 93Zr spectrum obtained by interpolation between experimental spectra from the two neighboring stable isotopes 92Zr and 94Zr. Assuming realistic numbers for chemical niobium reduction, a detection level of 93Zr/Zr below 10-9 seems feasible.

  10. The influence of restricted geometry of diamagnetic nanoporous media on 3He relaxation

    NASA Astrophysics Data System (ADS)

    Alakshin, E. M.; Gazizulin, R. R.; Zakharov, M. Yu.; Klochkov, A. V.; Morozov, E. V.; Salikhov, T. M.; Safin, T. R.; Safiullin, K. R.; Tagirov, M. S.; Shabanova, O. B.

    2015-01-01

    This is an experimental study of the spin kinetics of 3He in contact with diamagnetic samples of inverse opals SiO2, and LaF3 nanopowder. It is demonstrated that the nuclear magnetic relaxation of the absorbed 3He occurs due to the modulation of dipole-dipole interaction by the quantum motion in the two-dimensional film. It is found that the relaxation of liquid 3He occurs through a spin diffusion to the absorption layer, and that the restricted geometry of diamagnetic nanoporous media has an influence on the 3He relaxation.

  11. Model formalism of liquid /sup 3/He-B at equilibrium

    SciTech Connect

    Goldstein, L.; Goldstein, J.C.

    1980-04-01

    The approximate formal treatment of the nuclear spin system of normal liquid /sup 3/He given some time ago is extended to the ordered /sup 3/He phase. The formalism leads to the prediction of normal thermal behavior of /sup 3/He-B at lower pressures and at temperatures approaching its phase-boundary temperatures. In contrast to the disordered normal liquid phase, which is thermally anomalous, the entropy of the /sup 3/He-B decreases on isothermal compression, or its isobaric volume expansion coefficient is positive. The equilibrium thermal behavior of ordered /sup 3/He-B is thus qualitatively different from that of disordered liquid /sup 3/He. Experimental control of these aspects of the liquid /sup 3/He phase transformation is lacking at the present time. Both early and new /sup 3/He-B paramagnetic susceptibility data, extended recently over a wide reduced-temperature range, disclose a fundamental competition between the spontaneous ordering mechanism responsible for the existence of /sup 3/He-B and the specific ordering process imposed upon this phase on application of an external constant and uniform magnetic field. As a consequence, magnetized /sup 3/He-B will be shown to increase its entropy on isothermal magnetization and to cool on adiabatic magnetization. The magnetocaloric effect is, however, only moderate. The competition of the ordering process leads to the delay or possibly even to the suppression of the formation of the ordered phase, a state of affairs foreseen in our earlier work. At low or moderate magnetic field strengths, the zero-field phase-boundary temperatures are shown to shift toward lower temperatures while, simultaneously, the order of the phase change decreases, from second order, in the absence of the field, to first order. Although of model-theoretic character, involving limitations of various types, the rich physical content of /sup 3/He-B at equilibrium clearly emerges in the present work.

  12. Possible Dimensional Crossover to 1D of ^3He Fluid in Nanochannels Observed in Susceptibilities

    NASA Astrophysics Data System (ADS)

    Matsushita, Taku; Kurebayashi, Katsuya; Shibatsuji, Ryosuke; Hieda, Mitsunori; Wada, Nobuo

    2016-05-01

    Dimensional crossover to the one-dimensional (1D) state from higher dimensions has been studied for dilute ^3He fluid adsorbed in 2.4 nm ^4He-preplated nanochannels, by susceptibility measurements down to 70 mK using 4.29 MHz nuclear magnetic resonance. In nanochannels, since energy states of ^3He motion perpendicular to the channel axis are discrete, a genuine 1D ^3He fluid is expected when the Fermi energy is less than the first excitation Δ _{01} for azimuthal motion. The susceptibilities χ above 0.3 K show the Curie-law susceptibilities independent of the ^3He density, which are characteristic of nondegenerate fluid in higher dimensions. With decreasing the temperature, a significant reduction of χ T was observed from about 0.3 K for all ^3He densities. It is considered to be due to the dimensional crossover below Δ _{01}˜ 0.5 K to the 1D ^3He state in the semi-degenerate regime above the Fermi temperature. In the 1D state at lower temperatures, T-independent χ were observed for ^3He of 0.019 layers below 0.1 K. It suggests that the 1D ^3He fluid enters the quantum degenerate regime.

  13. Measurement of fast minority /sub 3/He/sup + +/ energy distribution during ICRF heating

    DOEpatents

    Post, D.E. Jr.; Grisham, L.R.; Medley, S.S.

    A method and means for measuring the fast /sub 3/He/sup + +/ distribution during /sub 3/He/sup + +/ minority Ion Cyclotron Resonance Frequency (ICRF) heating is disclosed. The present invention involves the use of 10 to 100 keV beams of neutral helium atoms to neutralize the fast /sub 3/He/sup + +/ ions in a heated plasma by double charge exchange (/sub 3/He/sup + +/ + /sub 4/He/sup 0/ ..-->.. /sub 3/He/sup 0/ + /sub 4/He/sup + +/). The neutralized fast /sub 3/He/sup 0/ atoms then escape from the hot plasma confined by a magnetic field and are detected by conventional neutral particle analyzing means. This technique permits the effectiveness of the coupling of the ion cyclotron waves to the /sub 3/He/sup + +/ minority ions to be accurately measured. The present invention is particularly adapted for use in evaluating the effectiveness of the intermediate coupling between the RF heating and the /sub 3/He/sup + +/ in an energetic toroidal plasma.

  14. Flow chamber

    DOEpatents

    Morozov, Victor

    2011-01-18

    A flow chamber having a vacuum chamber and a specimen chamber. The specimen chamber may have an opening through which a fluid may be introduced and an opening through which the fluid may exit. The vacuum chamber may have an opening through which contents of the vacuum chamber may be evacuated. A portion of the flow chamber may be flexible, and a vacuum may be used to hold the components of the flow chamber together.

  15. First measurement of the helicity dependence of 3He photoreactions in the Δ(1232) resonance region

    NASA Astrophysics Data System (ADS)

    Costanza, Susanna

    2014-03-01

    The first measurement of the helicity dependence for several photo-reaction channels on 3He was carried out in the photon energy range between 150 and 500 MeV at the MAMI accelerator (Mainz). The experiment used the large acceptance Crystal Ball spectrometer, complemented by charged particle and vertex detectors, a circularly polarised tagged photon beam and a longitudinally polarised high-pressure 3He gas target. Results of the helicity dependent total inclusive photoabsorption cross section on 3He and of both the unpolarised and polarised partial cross sections for the pion photoproduction channels γ 3He → πX and for the γ 3He → ppn channel, measured for the first time at MAMI, will be shown. They can also be found in [1].

  16. Nuclear georeactor origin of oceanic basalt 3He/4He, evidence, and implications

    PubMed Central

    Herndon, J. Marvin

    2003-01-01

    Nuclear georeactor numerical simulation results yield substantial 3He and 4He production and 3He/4He ratios relative to air (RA) that encompass the entire 2-SD (2σ) confidence level range of tabulated measured 3He/4He ratios of basalts from along the global spreading ridge system. Georeactor-produced 3He/4He ratios are related to the extent of actinide fuel consumption at time of production and are high near the end of the georeactor lifetime. Georeactor numerical simulation results and the observed high 3He/4He ratios measured in Icelandic and Hawaiian oceanic basalts indicate that the demise of the georeactor is approaching. Within the present level of uncertainty, one cannot say precisely when georeactor demise will occur, whether in the next century, in a million years, or in a billion years from now. PMID:12615991

  17. Electron bubbles and Weyl fermions in chiral superfluid 3He-A

    NASA Astrophysics Data System (ADS)

    Shevtsov, Oleksii; Sauls, J. A.

    2016-08-01

    Electrons embedded in liquid 3He form mesoscopic bubbles with large radii compared to the interatomic distance between 3He atoms, voids of Nbubble≈200 3He atoms, generating a negative ion with a large effective mass that scatters thermal excitations. Electron bubbles in chiral superfluid 3He-A also provide a local probe of the ground state. We develop a scattering theory of Bogoliubov quasiparticles by negative ions embedded in 3He-A that incorporates the broken symmetries of 3He-A , particularly broken symmetries under time reversal and mirror symmetry in a plane containing the chiral axis l ̂. Multiple scattering by the ion potential, combined with branch conversion scattering by the chiral order parameter, leads to a spectrum of Weyl fermions bound to the ion that support a mass current circulating the electron bubble—a mesoscopic realization of chiral edge currents in superfluid 3He-A films. A consequence is that electron bubbles embedded in 3He-A acquire angular momentum, L ≈-(Nbubble/2 ) ℏ l ̂ , inherited from the chiral ground state. We extend the scattering theory to calculate the forces on a moving electron bubble, both the Stokes drag and a transverse force, FW=e/c v ×BW , defined by an effective magnetic field, BW∝l ̂ , generated by the scattering of thermal quasiparticles off the spectrum of Weyl fermions bound to the moving ion. The transverse force is responsible for the anomalous Hall effect for electron bubbles driven by an electric field reported by the RIKEN group. Our results for the scattering cross section, drag, and transverse forces on moving ions are compared with experiments and shown to provide a quantitative understanding of the temperature dependence of the mobility and anomalous Hall angle for electron bubbles in normal and superfluid 3He-A . We also discuss our results in relation to earlier work on the theory of negative ions in superfluid 3He.

  18. 3He and BF 3 neutron detector pressure effect and model comparison

    NASA Astrophysics Data System (ADS)

    Lintereur, Azaree; Conlin, Kenneth; Ely, James; Erikson, Luke; Kouzes, Richard; Siciliano, Edward; Stromswold, David; Woodring, Mitchell

    2011-10-01

    Radiation detection systems for homeland security applications must possess the capability of detecting both gamma rays and neutrons. The radiation portal monitor systems that are currently deployed use a plastic scintillator for detecting gamma rays and 3He gas-filled proportional counters for detecting neutrons. Proportional counters filled with 3He are the preferred neutron detectors for use in radiation portal monitor systems because 3He has a large neutron cross-section, is relatively insensitive to gamma-rays, is neither toxic nor corrosive, can withstand extreme environments, and can be operated at a lower voltage than some of the alternative proportional counters. The amount of 3He required for homeland security and science applications has depleted the world supply and there is no longer enough available to fill the demand. Thus, alternative neutron detectors are being explored. Two possible temporary solutions that could be utilized while a more permanent solution is being identified are reducing the 3He pressure in the proportional counters and using boron trifluoride gas-filled proportional counters. Reducing the amount of 3He required in each of the proportional counters would decrease the rate at which 3He is being used; not enough to solve the shortage, but perhaps enough to increase the amount of time available to find a working replacement. Boron trifluoride is not appropriate for all situations as these detectors are less sensitive than 3He, boron trifluoride gas is corrosive, and a much higher voltage is required than what is used with 3He detectors. Measurements of the neutron detection efficiency of 3He and boron trifluoride as a function of tube pressure were made. The experimental results were also used to validate models of the radiation portal monitor systems.

  19. Accuracy of the electron transport in mcnp5 and its suitability for ionization chamber response simulations: A comparison with the egsnrc and penelope codes

    SciTech Connect

    Koivunoro, Hanna; Siiskonen, Teemu; Kotiluoto, Petri; Auterinen, Iiro; Hippelaeinen, Eero; Savolainen, Sauli

    2012-03-15

    Purpose: In this work, accuracy of the mcnp5 code in the electron transport calculations and its suitability for ionization chamber (IC) response simulations in photon beams are studied in comparison to egsnrc and penelope codes. Methods: The electron transport is studied by comparing the depth dose distributions in a water phantom subdivided into thin layers using incident energies (0.05, 0.1, 1, and 10 MeV) for the broad parallel electron beams. The IC response simulations are studied in water phantom in three dosimetric gas materials (air, argon, and methane based tissue equivalent gas) for photon beams ({sup 60}Co source, 6 MV linear medical accelerator, and mono-energetic 2 MeV photon source). Two optional electron transport models of mcnp5 are evaluated: the ITS-based electron energy indexing (mcnp5{sub ITS}) and the new detailed electron energy-loss straggling logic (mcnp5{sub new}). The electron substep length (ESTEP parameter) dependency in mcnp5 is investigated as well. Results: For the electron beam studies, large discrepancies (>3%) are observed between the mcnp5 dose distributions and the reference codes at 1 MeV and lower energies. The discrepancy is especially notable for 0.1 and 0.05 MeV electron beams. The boundary crossing artifacts, which are well known for the mcnp5{sub ITS}, are observed for the mcnp5{sub new} only at 0.1 and 0.05 MeV beam energies. If the excessive boundary crossing is eliminated by using single scoring cells, the mcnp5{sub ITS} provides dose distributions that agree better with the reference codes than mcnp5{sub new}. The mcnp5 dose estimates for the gas cavity agree within 1% with the reference codes, if the mcnp5{sub ITS} is applied or electron substep length is set adequately for the gas in the cavity using the mcnp5{sub new}. The mcnp5{sub new} results are found highly dependent on the chosen electron substep length and might lead up to 15% underestimation of the absorbed dose. Conclusions: Since the mcnp5 electron

  20. T(T,2n)4He and 3He(3He,2p)4He: The Reaction Mechanism from Solar Energies to 10 MeV

    NASA Astrophysics Data System (ADS)

    Bacher, A. D.; Brune, C. R.; Sayre, D. B.; Hale, G. M.; Frenje, J. A.; Gatu Johnson, M.

    2016-03-01

    We have studied the energy dependence of the reaction mechanism of the T(t,2n)4He reaction at stellar energies and of its charge symmetric analog reaction 3He(3He,2p)4He at energies up 10 MeV. We find that the reaction mechanism changes dramatically over this energy range in part due to the interference of the two identical fermions in the three-body final state. This contribution is dedicated to the memory of Tom Tombrello, my Ph.D. advisor at Cal Tech, who died in 2014.

  1. Search for anomalous deuterons in the reaction /sup 3/He+C. -->. d+X at p3He = 10. 8 GeV/c

    SciTech Connect

    Ableev, V.G.; Vorob'ev, G.G.; Gasparyan, A.P.; Grigalashvili, N.S.; Dzhmukhadze, S.V.; Zaporozhets, S.A.; Nomofilov, A.A.; Piskunov, N.M.; Sitnik, I.M.; Strokovskii, E.A.

    1985-07-01

    The Alpha apparatus in a beam of 10.78-GeV/c /sup 3/He nuclei has been used to search for anomalous deuterons (demons) in the reaction /sup 3/He+C ..-->.. d+X. The deuteron yield was measured at angles theta< or approx. =20 mrad as a function of the target thickness, which varied from 0.6 to 70 cm. The data obtained exclude the production of demons in this reaction over a wide range of expected values of the cross sections for their production and interaction with matter. The technique used can be applied also to beams of relativistic nuclei in experiments to search for anomalons.

  2. SU-E-T-552: Monte Carlo Calculation of Correction Factors for a Free-Air Ionization Chamber in Support of a National Air-Kerma Standard for Electronic Brachytherapy

    SciTech Connect

    Mille, M; Bergstrom, P

    2015-06-15

    Purpose: To use Monte Carlo radiation transport methods to calculate correction factors for a free-air ionization chamber in support of a national air-kerma standard for low-energy, miniature x-ray sources used for electronic brachytherapy (eBx). Methods: The NIST is establishing a calibration service for well-type ionization chambers used to characterize the strength of eBx sources prior to clinical use. The calibration approach involves establishing the well-chamber’s response to an eBx source whose air-kerma rate at a 50 cm distance is determined through a primary measurement performed using the Lamperti free-air ionization chamber. However, the free-air chamber measurements of charge or current can only be related to the reference air-kerma standard after applying several corrections, some of which are best determined via Monte Carlo simulation. To this end, a detailed geometric model of the Lamperti chamber was developed in the EGSnrc code based on the engineering drawings of the instrument. The egs-fac user code in EGSnrc was then used to calculate energy-dependent correction factors which account for missing or undesired ionization arising from effects such as: (1) attenuation and scatter of the x-rays in air; (2) primary electrons escaping the charge collection region; (3) lack of charged particle equilibrium; (4) atomic fluorescence and bremsstrahlung radiation. Results: Energy-dependent correction factors were calculated assuming a monoenergetic point source with the photon energy ranging from 2 keV to 60 keV in 2 keV increments. Sufficient photon histories were simulated so that the Monte Carlo statistical uncertainty of the correction factors was less than 0.01%. The correction factors for a specific eBx source will be determined by integrating these tabulated results over its measured x-ray spectrum. Conclusion: The correction factors calculated in this work are important for establishing a national standard for eBx which will help ensure that dose

  3. Quasielastic charge-exchange reaction p/sup 3/ He. -->. n/sub F/ ppp at intermediate energies

    SciTech Connect

    Blinov, A.V.; Vanyushin, I.A.; Grechko, V.E.; Zombkovskii, S.M.; Kondratyuk, L.A.; Korolev, Y.V.; Selektor, Y.M.; Solov'ev, V.V.; Turov, V.F.; Chuvilo, I.V.; and others

    1988-04-01

    The principal characteristics of the quasielastic-charge-exchange reaction p/sup 3/He..-->..n/sub F/ppp are investigated by means of the liquid-hydrogen bubble chamber at our institute of diameter 80 cm, exposed in beams of /sup 3/He nuclei with momenta 2.5 and 5 GeV/c (the kinetic energy of the primary protons T/sub p/ in the rest system of the nucleus is respectively 0.318 and 0.978 GeV). The experimental data are compared with the predictions of the Glauber-Sitenko multiple-scattering theory and with the pole model taking into account the interaction of spectator nucleons in the final state. In the mass spectrum of the 3p system at 3.05 GeV a well expressed structure is observed which is not described in the framework of the pole model. A possible resonance occurrence of this structure is discussed.

  4. Calorimetric determination of kQ factors for NE 2561 and NE 2571 ionization chambers in 5 cm × 5 cm and 10 cm × 10 cm radiotherapy beams of 8 MV and 16 MV photons

    NASA Astrophysics Data System (ADS)

    Krauss, Achim; Kapsch, Ralf-Peter

    2007-10-01

    The relative uncertainty of the ionometric determination of the absorbed dose to water, Dw, in the reference dosimetry of high-energy photon beams is in the order of 1.5% and is dominated by the uncertainty of the calculated chamber- and energy-dependent correction factors kQ. In the present investigation, kQ values were determined experimentally in 5 cm × 5 cm and 10 cm × 10 cm radiotherapy beams of 8 MV and 16 MV bremsstrahlung by means of a water calorimeter operated at 4 °C. Ionization chambers of the types NE 2561 and NE 2571 were calibrated directly in the water phantom of the calorimeter. The measurements were carried out at the linear accelerator of the Physikalisch-Technische Bundesanstalt. It is shown that the kQ factor of a single ionization chamber can be measured with a standard uncertainty of less than 0.3%. No significant variations of kQ were found for the different lateral sizes of the radiation fields used in this investigation.

  5. The injection of ten electron/3He-rich SEP events

    NASA Astrophysics Data System (ADS)

    Wang, Linghua; Krucker, Säm; Mason, Glenn M.; Lin, Robert P.; Li, Gang

    2016-01-01

    We have derived the particle injections at the Sun for ten good electron/3He-rich solar energetic particle (SEP) events, using a 1.2 AU particle path length (suggested by analysis of the velocity dispersion). The inferred solar injections of high-energy (~10 to 300 keV) electrons and of ~MeV/nucleon ions (carbon and heavier) start with a delay of 17 ± 3 min and 75 ± 14 min, respectively, after the injection of low-energy (~0.4 to 9 keV) electrons. The injection duration (averaged over energy) ranges from ~200 to 550 min for ions, from ~90 to 160 min for low-energy electrons, and from ~10 to 30 min for high-energy electrons. Most of the selected events have no reported Hα flares or GOES SXR bursts, but all have type III radio bursts that typically start after the onset of a low-energy electron injection. All nine events with SOHO/LASCO coverage have a relatively fast (>570 km s-1), mostly narrow (≲30°), west-limb coronal mass ejection (CME) that launches near the start of the low-energy electron injection, and reaches an average altitude of ~1.0 and 4.7 RS, respectively, at the start of the high-energy electron injection and of the ion injection. The electron energy spectra show a continuous power law extending across the transition from low to high energies, suggesting that the low-energy electron injection may provide seed electrons for the delayed high-energy electron acceleration. The delayed ion injections and high ionization states may suggest an ion acceleration along the lower altitude flanks, rather than at the nose of the CMEs.

  6. PREFACE: JCNS Workshop on Modern Trends in Production and Applications of Polarized 3He

    NASA Astrophysics Data System (ADS)

    Ioffe, Alexander; Babcock, Earl; Gutberlet, Thomas

    2011-03-01

    Polarized neutron scattering techniques are an indispensable and highly requested tool for studying magnetic phenomena in condensed matter. The different coherent and incoherent scattering of isotopes such as protons and deuterons also allows applications of polarized neutrons in soft matter and biological studies of molecular and macromolecular dynamics. One method to polarize neutrons is to use polarized 3He gas which absorbs, or filters, one spin state of the neutron beam as it passes through it. Only about ten years ago, early polarized neutron scattering experiments using such 3He neutron spin filters (3He NSF) were being conducted using starting 3He polarizations of 55%. Currently there are two different commonly used methods to polarize high quantities of 3He. These methods both collisionally transfer spin polarization to ground state 3He nucleuses; one method uses optical pumping of an excited metastable state of 3He atoms, and the other uses optical pumping of the ground state of an alkali-metal vapour. Within the last decade immense progress in both methods has resulted in 3He polarizations of up to 80% being reported in atmosphere-pressure 3He cells by the world's leading labs. This progress in optical pumped 3He promises to give rise to much more efficient and novel polarized neutron scattering experiments as and also impacts other areas of science. Polarized 3He is additionally applied in research fields such as particle physics, fundamental studies and medicine. Thus not only the techniques and methods of polarization, but the research groups themselves exploring polarized 3He, have a large breadth and diversity spanning different fields of science and locations in the world. Given this diversity, it is rare for this community to meet as a group at any one meeting or conference. Because it is crucial to discuss new developments in 3He polarization in a multi-disciplinary international setting, an international workshop on "Modern Trends in Production

  7. The cosmological density of baryons from observations of 3He+ in the Milky Way.

    PubMed

    Bania, T M; Rood, Robert T; Balser, Dana S

    2002-01-01

    Primordial nucleosynthesis after the Big Bang can be constrained by the abundances of the light elements and isotopes 2H, 3He, 4He and 7Li (ref. 1). The standard theory of stellar evolution predicts that 3He is also produced by solar-type stars, so its abundance is of interest not only for cosmology, but also for understanding stellar evolution and the chemical evolution of the Galaxy. The 3He abundance in star-forming (H II) regions agrees with the present value for the local interstellar medium, but seems to be incompatible with the stellar production rates inferred from observations of planetary nebulae, which provide a direct test of stellar evolution theory. Here we develop our earlier observations, which, when combined with recent theoretical developments in our understanding of light-element synthesis and destruction in stars, allow us to determine an upper limit for the primordial abundance of 3He relative to hydrogen: 3He/H = (1.1 +/- 0.2) x 10(-5). The primordial density of all baryons determined from the 3He data is in excellent agreement with the densities calculated from other cosmological probes. The previous conflict is resolved because most solar-mass stars do not produce enough 3He to enrich the interstellar medium significantly. PMID:11780112

  8. Anomalous yield reduction in direct-drive DT implosions due to 3He addition

    SciTech Connect

    Herrmann, Hans W; Langenbrunner, James R; Mack, Joseph M; Cooley, James H; Wilson, Douglas C; Evans, Scott C; Sedillo, Tom J; Kyrala, George A; Caldwell, Stephen E; Young, Carlton A; Nobile, Arthur; Wermer, Joseph R; Paglieri, Stephen N; Mcevoy, Aaron M; Kim, Yong Ho; Batha, Steven H; Horsfield, Colin J; Drew, Dave; Garbett, Warren; Rubery, Michael; Glebov, Vladimir Yu; Roberts, Samuel; Frenje, Johan A

    2008-01-01

    Glass capsules were imploded in direct drive on the OMEGA laser [T. R. Boehly et aI., Opt. Commun. 133, 495, 1997] to look for anomalous degradation in deuterium/tritium (DT) yield (i.e., beyond what is predicted) and changes in reaction history with {sup 3}He addition. Such anomalies have previously been reported for D/{sup 3}He plasmas, but had not yet been investigated for DT/{sup 3}He. Anomalies such as these provide fertile ground for furthering our physics understanding of ICF implosions and capsule performance. A relatively short laser pulse (600 ps) was used to provide some degree of temporal separation between shock and compression yield components for analysis. Anomalous degradation in the compression component of yield was observed, consistent with the 'factor of two' degradation previously reported by MIT at a 50% {sup 3}He atom fraction in D{sub 2} using plastic capsules [Rygg et aI., Phys. Plasmas 13, 052702 (2006)]. However, clean calculations (i.e., no fuel-shell mixing) predict the shock component of yield quite well, contrary to the result reported by MIT, but consistent with LANL results in D{sub 2}/{sup 3}He [Wilson, et aI., lml Phys: Conf Series 112, 022015 (2008)]. X-ray imaging suggests less-than-predicted compression ofcapsules containing {sup 3}He. Leading candidate explanations are poorly understood Equation-of-State (EOS) for gas mixtures, and unanticipated particle pressure variation with increasing {sup 3}He addition.

  9. Third sound and stability of 3He-4He mixture films

    SciTech Connect

    Anderson, R. H.; Krotscheck, E.; Miller, M. D.

    2006-09-07

    We study third sound and the interaction between 3He adatoms in two thin 3He-4He mixture films from a first-principles, microscopic theory. Utilizing the variational, hypernetted-chain Euler-Lagrange (HNC-EL) theory as applied to inhomogeneous boson systems, we calculate chemical potentials for both the 4He superfluid film and the physisorbed 3He. Numerical density derivatives of the chemical potentials lead to the sought-after third sound speeds that clearly reflect a layered structure of at least seven oscillations. In this paper, we report third sound on model substrates: Nuclepore, and sodium. We find that the effect of the 3He depends sensitively on the particular 4He film coverage. Our most important result is that, with the addition of 3He, the third sound speed can either increase or decrease. In fact, in some regimes, the added 3He destabilizes the film and can drive ''layering transitions'', leading to fairly complicated geometric structures of the film in which the outermost layer is predicted to consist of phase-separated regions of 3He and 4He.

  10. Recent advances in polarized 3 He based neutron spin filter development

    NASA Astrophysics Data System (ADS)

    Chen, Wangchun; Gentile, Thomas; Erwin, Ross; Watson, Shannon; Krycka, Kathryn; Ye, Qiang; NCNR NIST Team; University of Maryland Team

    2015-04-01

    Polarized 3 He neutron spin filters (NSFs) are based on the strong spin-dependence of the neutron absorption cross section by 3 He. NSFs can polarize large area, widely divergent, and broadband neutron beams effectively and allow for combining a neutron polarizer and a spin flipper into a single polarizing device. The last capability utilizes 3 He spin inversion based on the adiabatic fast passage (AFP) nuclear magnetic resonance technique. Polarized 3 He NSFs are significantly expanding the polarized neutron measurement capabilities at the NIST Center for Neutron Research (NCNR). Here we present an overview of 3 He NSF applications to small-angle neutron scattering, thermal triple axis spectrometry, and wide-angle polarization analysis. We discuss a recent upgrade of our spin-exchange optical pumping (SEOP) systems that utilize chirped volume holographic gratings for spectral narrowing. The new capability allows us to polarize rubidium/potassium hybrid SEOP cells over a liter in volume within a day, with 3 He polarizations up to 88%, Finally we discuss how we can achieve nearly lossless 3 He polarization inversion with AFP.

  11. Multi-spacecraft observations of recurrent {sup 3}He-rich solar energetic particles

    SciTech Connect

    Bučík, R.; Innes, D. E.; Mall, U.; Korth, A.; Mason, G. M.; Gómez-Herrero, R.

    2014-05-01

    We study the origin of {sup 3}He-rich solar energetic particles (<1 MeV nucleon{sup –1}) that are observed consecutively on STEREO-B, Advanced Composition Explorer (ACE), and STEREO-A spacecraft when they are separated in heliolongitude by more than 90°. The {sup 3}He-rich period on STEREO-B and STEREO-A commences on 2011 July 1 and 2011 July 16, respectively. The ACE {sup 3}He-rich period consists of two sub-events starting on 2011 July 7 and 2011 July 9. We associate the STEREO-B July 1 and ACE July 7 {sup 3}He-rich events with the same sizeable active region (AR) producing X-ray flares accompanied by prompt electron events, when it was near the west solar limb as seen from the respective spacecraft. The ACE July 9 and STEREO-A July 16 events were dispersionless with enormous {sup 3}He enrichment, lacking solar energetic electrons and occurring in corotating interaction regions. We associate these events with a small, recently emerged AR near the border of a low-latitude coronal hole that produced numerous jet-like emissions temporally correlated with type III radio bursts. For the first time we present observations of (1) solar regions with long-lasting conditions for {sup 3}He acceleration and (2) solar energetic {sup 3}He that is temporarily confined/re-accelerated in interplanetary space.

  12. Cosmogenic 3He in terrestrial rocks: The summit lavas of Maui

    PubMed Central

    Craig, H.; Poreda, R. J.

    1986-01-01

    We have identified terrestrial cosmic rayproduced 3He in three lava flows on the crest of Haleakala Volcano on Maui, 3 km above sea level, and ≈0.5 million years old. Although these lavas, like all oceanic basalts, contain primordial 3He from the mantle, the “cosmogenic” component (3HeC) can be identified unambiguously because it is extractable only by high-temperature vacuum fusion. In contrast, a large fraction of the mantle helium resides in fluid inclusions and can be extracted by vacuum crushing, leaving a residual component with 3He/4He ratios as high as 75× those in the atmosphere, which can be liberated by melting the crushed grains. Cosmogenic 3He is present in both olivines and clinopyroxenes at 0.8-1.2 × 10-12 ml(STP)/g and constitutes 75% ± 5% of the total 3He present. The observed 3HeC levels require a cosmic ray exposure age of only some 64,000 years, much less than the actual age of the lavas, if there is no erosion. Using a model that includes effects of uplift or submergence as well as erosion, we calculate an apparent “erosion rate” of the order of 8.5 m/106 years for the western rim of the summit crater, as an example of the application of measurements of cosmogenic rare gases to terrestrial geological problems. PMID:16593671

  13. Gas cells for 3He hyperpolarized via spin-exchange optical pumping

    NASA Astrophysics Data System (ADS)

    Kim, W.; Stepanyan, S. S.; Kim, A.; Tan, J. A.; Woo, S.

    2016-01-01

    We present a device for the production of hyperpolarized 3He, which is widely used in spinrelated nuclear physics research. Spin-exchange optical pumping (SEOP) is employed to polarize 3He enclosed in a circular borosilicate glass cell suitable not only for the production of polarized gas but also for its storage. The portable glass cell can, thus, be transported to any other research facility. The glass cell can be refilled several times. Special attention is given to the preparation and the filling of the cell to minimize the impurities on its walls and in the gas. We employ glass tubes with shorter lengths and larger diameters in the gas-filling system to achieve the improvement in the air flow necessary to obtain purer polarized 3He samples. The cell is prepared, and after it has been filled with rubidium (Rb) and 3He-N2 mixture, it is sealed under high vacuum conditions. The cell containing the mixture is exposed to circularly-polarized laser light with a wavelength of 795 nm at temperatures of 180 - 220 °C for SEOP. The polarization of 3He is measured via nuclear magnetic resonance (NMR). We obtained 40% polarized 3He in less than 15 hours and 50% in about 25 hours. The longitudinal relaxation time T 1 of the polarized 3He we measured was about 58 hours.

  14. Investigation of the {sup 3}He wave function by quasifree scattering

    SciTech Connect

    Jones, C.E.; Hansen, J.O.; Bloch, C.

    1995-08-01

    The analysis of the data from the CE25 experiment at IUCF, which measured the target and beam analyzing powers and the spin correlation parameter in {sup 3}He(p,2p) and {sup 3}He(p,pn) quasielastic scattering, is nearing completion. At low missing momentum, the extracted polarization of the neutron and proton in {sup 3}He are consistent with Faddeev calculations. Two papers, one reporting the physics results and one describing the experiment, were published. The data from this experiment indicates that for q {>=} 500 MeV/c the plane wave impulse approximation is valid.

  15. Polarized {sup 3}He{sup −} ion source with hyperfine state selection

    SciTech Connect

    Dudnikov, V.; Morozov, V.; Dudnikov, A.

    2015-04-08

    High beam polarization is essential to the scientific productivity of a collider. Polarized {sup 3}He ions are an essential part of the nuclear physics programs at existing and future ion-ion and electron-ion colliders such as BNL's RHIC and eRHIC and JLab's ELIC. Ion sources with performance exceeding that achieved today are a key requirement for the development of these next generation high-luminosity high-polarization colliders. The development of high-intensity high-brightness arc-discharge ion sources at the Budker Institute of Nuclear Physics (BINP) has opened up an opportunity for realization of a new type of a polarized {sup 3}He{sup −} ion source. This report discusses a polarized {sup 3}He{sup −} ion source based on the large difference of extra-electron auto-detachment lifetimes of the different {sup 3}He{sup −} ion hyperfine states. The highest momentum state of 5/2 has the largest lifetime of τ ∼ 350 µs while the lower momentum states have lifetimes of τ ~ 10 µs. By producing {sup 3}He{sup −} ion beam composed of only the |5/2, ±5/2> hyperfine states and then quenching one of the states by an RF resonant field, {sup 3}He{sup −} beam polarization of 90% can be achieved. Such a method of polarized {sup 3}He{sup −} production has been considered before; however, due to low intensities of the He{sup +} ion sources existing at that time, it was not possible to produce any interesting intensity of polarized {sup 3}He{sup −} ions. The high-brightness arc-discharge ion source developed at BINP can produce a high-brightness {sup 3}He{sup +} beam with an intensity of up to 2 A allowing for selection of up to ∼1-4 mA of {sup 3}He{sup −} ions with ∼90% polarization. The high gas efficiency of an arc-discharge source is important due to the high cost of {sup 3}He gas. Some features of such a PIS as well as prototype designs are considered. An integrated {sup 3}He{sup −} ion source design providing high beam polarization could be

  16. A polarized internal sup 3 He target using optical pumping of metastable atoms

    SciTech Connect

    McKeown, R.D.; Milner, R.G.; Woodward, C.E. )

    1989-05-05

    The design of a polarized internal {sup 3}He target for use in storage rings based on optical pumping of metastables is discussed. The target employs an infrared laser to polarize {sup 3}He atoms in a pyrex cell which is connected by a capillary to a windowless cell through which the stored beam passes. Using this technique it should be possible construct targets of 50% polarized {sup 3}He targets of thickness 10{sup 16} cm{sup {minus}2}. Small holding fields ({similar to}10 gauss) and resistance to beam-induced depolarization are desirable features of this target in a storage ring environment.

  17. Experimental investigation and theoretical calculation for 3He induced nuclear reactions on vanadium

    NASA Astrophysics Data System (ADS)

    Ali, B. M.; Al-Abyad, M.; Seddik, U.; El-Kameesy, S. U.; Ditrói, F.; Takács, S.; Tárkányi, F.

    2016-04-01

    Using stacked-foil activation technique and gamma-ray spectrometry, excitation functions for 3He induced nuclear reactions on natV were measured. Cross-sections for natV(3He, xn)52m,gMn and natV(3He, pxn)51Cr nuclear reactions were measured up to 27 MeV utilizing the MGC-20E cyclotron of ATOMKI. The measurements establish for the first time consistent excitation curves. Comparisons with results for values derived from different theoretical codes were included. Integral yield were calculated.

  18. Triple oxygen isotopic composition of the high-3He/4He mantle

    NASA Astrophysics Data System (ADS)

    Starkey, N. A.; Jackson, C. R. M.; Greenwood, R. C.; Parman, S.; Franchi, I. A.; Jackson, M.; Fitton, J. G.; Stuart, F. M.; Kurz, M.; Larsen, L. M.

    2016-03-01

    Measurements of Xe isotope ratios in ocean island basalts (OIB) suggest that Earth's mantle accreted heterogeneously, and that compositional remnants of accretion are sampled by modern, high-3He/4He OIB associated with the Icelandic and Samoan plumes. If so, the high-3He/4He source may also have a distinct oxygen isotopic composition from the rest of the mantle. Here, we test if the major elements of the high-3He/4He source preserve any evidence of heterogeneous accretion using measurements of three oxygen isotopes on olivine from a variety of high-3He/4He OIB locations. To high precision, the Δ17O value of high-3He/4He olivines from Hawaii, Pitcairn, Baffin Island and Samoa, are indistinguishable from bulk mantle olivine (Δ17OBulk Mantle - Δ17OHigh 3He/4He olivine = -0.002 ± 0.004 (2 × SEM)‰). Thus, there is no resolvable oxygen isotope evidence for heterogeneous accretion in the high-3He/4He source. Modelling of mixing processes indicates that if an early-forming, oxygen-isotope distinct mantle did exist, either the anomaly was extremely small, or the anomaly was homogenised away by later mantle convection. The δ18O values of olivine with the highest 3He/4He ratios from a variety of OIB locations have a relatively uniform composition (∼5‰). This composition is intermediate to values associated with the depleted MORB mantle and the average mantle. Similarly, δ18O values of olivine from high-3He/4He OIB correlate with radiogenic isotope ratios of He, Sr, and Nd. Combined, this suggests that magmatic oxygen is sourced from the same mantle as other, more incompatible elements and that the intermediate δ18O value is a feature of the high-3He/4He mantle source. The processes responsible for the δ18O signature of high-3He/4He mantle are not certain, but δ18O-87Sr/86Sr correlations indicate that it may be connected to a predominance of a HIMU-like (high U/Pb) component or other moderate δ18O components recycled into the high-3He/4He source.

  19. Practical method for determination of air kerma by use of an ionization chamber toward construction of a secondary X-ray field to be used in clinical examination rooms.

    PubMed

    Maehata, Itsumi; Hayashi, Hiroaki; Kimoto, Natsumi; Takegami, Kazuki; Okino, Hiroki; Kanazawa, Yuki; Tominaga, Masahide

    2016-07-01

    We propose a new practical method for the construction of an accurate secondary X-ray field using medical diagnostic X-ray equipment. For accurate measurement of the air kerma of an X-ray field, it is important to reduce and evaluate the contamination rate of scattered X-rays. To determine the rate quantitatively, we performed the following studies. First, we developed a shield box in which an ionization chamber could be set at an inner of the box to prevent detection of the X-rays scattered from the air. In addition, we made collimator plates which were placed near the X-ray source for estimation of the contamination rate by scattered X-rays from the movable diaphragm which is a component of the X-ray equipment. Then, we measured the exposure dose while changing the collimator plates, which had diameters of 25-90 mm(ϕ). The ideal value of the exposure dose was derived mathematically by extrapolation to 0 mm(ϕ). Tube voltages ranged from 40 to 130 kV. Under these irradiation conditions, we analyzed the contamination rate by the scattered X-rays. We found that the contamination rates were less than 1.7 and 2.3 %, caused by air and the movable diaphragm, respectively. The extrapolated value of the exposure dose has been determined to have an uncertainty of 0.7 %. The ionization chamber used in this study was calibrated with an accuracy of 5 %. Using this kind of ionization chamber, we can construct a secondary X-ray field with an uncertainty of 5 %. PMID:26994011

  20. Ionization detection system for aerosols

    DOEpatents

    Jacobs, Martin E.

    1977-01-01

    This invention relates to an improved smoke-detection system of the ionization-chamber type. In the preferred embodiment, the system utilizes a conventional detector head comprising a measuring ionization chamber, a reference ionization chamber, and a normally non-conductive gas triode for discharging when a threshold concentration of airborne particulates is present in the measuring chamber. The improved system utilizes a measuring ionization chamber which is modified to minimize false alarms and reductions in sensitivity resulting from changes in ambient temperature. In the preferred form of the modification, an annular radiation shield is mounted about the usual radiation source provided to effect ionization in the measuring chamber. The shield is supported by a bimetallic strip which flexes in response to changes in ambient temperature, moving the shield relative to the source so as to vary the radiative area of the source in a manner offsetting temperature-induced variations in the sensitivity of the chamber.

  1. Measurements of neutron-induced fission cross-sections of 205Tl, 204,206,207,208Pb and 209Bi with a multi-section Frisch-gridded ionization chamber

    NASA Astrophysics Data System (ADS)

    Ryzhov, I. V.; Tutin, G. A.; Mitryukhin, A. G.; Oplavin, V. S.; Soloviev, S. M.; Blomgren, J.; Renberg, P.-U.; Meulders, J. P.; El Masri, Y.; Keutgen, Th.; Prieels, R.; Nolte, R.

    2006-06-01

    Neutron-induced fission cross-sections of 205Tl, 204,206,207,208Pb and 209Bi have been measured in the energy range from 30 to 180 MeV. The measurements were performed with quasi-monoenergetic neutron beams using a multi-section Frisch-gridded ionization chamber. The neutron-induced fission cross-sections of 238U were used as reference data. The experimental techniques are described in detail as well as the data processing. The results are compared with existing experimental data.

  2. Kaonic 3He and 4He X-ray measurements in SIDDHARTA

    NASA Astrophysics Data System (ADS)

    Ishiwatari, Tomoichi; Bazzi, M.; Beer, G.; Berucci, C.; Bombelli, L.; Bragadireanu, A. M.; Cargnelli, M.; Clozza, A.; Corradi, G.; Curceanu (Petrascu), C.; d'Uffizi, A.; Fiorini, C.; Ghio, F.; Girolami, B.; Guaraldo, C.; Hayano, R. S.; Iliescu, M.; Iwasaki, M.; Kienle, P.; Levi Sandri, P.; Lucherini, V.; Marton, J.; Okada, S.; Pietreanu, D.; Piscicchia, K.; Poli Lener, M.; Ponta, T.; Quaglia, R.; Rizzo, A.; Romero Vidal, A.; Sbardella, E.; Scordo, A.; Shi, H.; Sirghi, D. L.; Sirghi, F.; Tatsuno, H.; Tudorache, A.; Tudorache, V.; Vazquez Doce, O.; Widmann, E.; Wünschek, B.; Zmeskal, J.

    2012-05-01

    The SIDDHARTA experiment measured the kaonic 3He and 4He 3 d →2 p X-ray transitions using gaseous targets for the first time. The strong-interaction shift both of the kaonic 3He and 4He 2 p states was determined with a precision of a few eV. The shift of kaonic 4He is much smaller than the values obtained in the experiments performed in 70's and 80's, while it is consistent with the recent result of the KEK E570 experiment, as well as the theoretical calculated values. Therefore, the problem on kaonic helium (the "kaonic helium puzzle") was definitely solved. The first observation of the kaonic 3He X-rays was also achieved in the SIDDHARTA experiment. The shift both of kaonic 3He and 4He was found to be as small as a few eV.

  3. Kaonic 3He and 4He X-ray measurements in SIDDHARTA

    NASA Astrophysics Data System (ADS)

    Ishiwatari, Tomoichi; Bazzi, M.; Beer, G.; Berucci, C.; Bombelli, L.; Bragadireanu, A. M.; Cargnelli, M.; Clozza, A.; Corradi, G.; Curceanu (Petrascu), C.; d'Uffizi, A.; Fiorini, C.; Ghio, F.; Girolami, B.; Guaraldo, C.; Hayano, R. S.; Iliescu, M.; Iwasaki, M.; Kienle, P.; Levi Sandri, P.; Lucherini, V.; Marton, J.; Okada, S.; Pietreanu, D.; Piscicchia, K.; Poli Lener, M.; Ponta, T.; Quaglia, R.; Rizzo, A.; Romero Vidal, A.; Sbardella, E.; Scordo, A.; Shi, H.; Sirghi, D. L.; Sirghi, F.; Tatsuno, H.; Tudorache, A.; Tudorache, V.; Vazquez Doce, O.; Widmann, E.; Wünschek, B.; Zmeskal, J.

    The SIDDHARTA experiment measured the kaonic 3He and 4He 3d →2p X-ray transitions using gaseous targets for the first time. The strong-interaction shift both of the kaonic 3He and 4He 2p states was determined with a precision of a few eV. The shift of kaonic 4He is much smaller than the values obtained in the experiments performed in 70's and 80's, while it is consistent with the recent result of the KEK E570 experiment, as well as the theoretical calculated values. Therefore, the problem on kaonic helium (the "kaonic helium puzzle") was definitely solved. The first observation of the kaonic 3He X-rays was also achieved in the SIDDHARTA experiment. The shift both of kaonic 3He and 4He was found to be as small as a few eV.

  4. Progress Towards the Detection of Faraday Rotation on Spin Polarized 3He

    NASA Astrophysics Data System (ADS)

    Abney, Josh; Broering, Mark; Korsch, Wolfgang

    2016-03-01

    Off-resonance Faraday rotation can offer a new method to monitor the nuclear spin polarization of a dense 3He target and gain access to new information about the magnetic polarizability of the 3He nucleus. The interaction of the polarization state of light with the nuclear spin of the helium atom is very weak and has never been detected. A sensitive triple modulation technique has been developed which can detect the expected rotation angle on the order of 100 nrad. Once a Faraday rotation signal is observed, the next step is to separate the magnetic and electric contributions to the rotation by utilizing their different frequency dependencies. Recent studies involved optimizing several parameters which impact 3He target polarization. Progress towards detecting nuclear spin optical rotation on 3He will be reported. This research is supported by DOE Grant DE-FG02-99ER41101.

  5. {sup 3}He polarization via optical pumping in a birefringent cell

    SciTech Connect

    Masuda, Y.; Ino, T.; Skoy, V.R.; Jones, G.L.

    2005-08-01

    A sapphire cell was used to obtain a high {sup 3}He nuclear polarization by means of spin-exchange optical pumping. The phase-shift difference between ordinary and extraordinary rays is well controlled using the thickness of the birefringent sapphire window so that a high circular polarization is obtained in the cell. Neutron transmission through the polarized {sup 3}He gas was measured as a function of neutron energy. A large {sup 3}He polarization of 63{+-}1% was obtained at a {sup 3}He pressure of 3.1 atm. Neutron polarizations of 97 and 90 % were obtained with transmission rates of 15 and 22 % at 10 and 20 meV, respectively.

  6. Magnetization and spin diffusion of liquid {sup 3}He in aerogel

    SciTech Connect

    Sauls, J. A.; Bunkov, Yu.M.; Collin, E.; Godfrin, H.; Sharma, P.

    2005-07-01

    We report theoretical calculations and experimental measurements of the normal-state spin diffusion coefficient of {sup 3}He in aerogel, including both elastic and inelastic scattering of {sup 3}He quasiparticles, and compare these results with data for {sup 3}He in 98% porous silica aerogel. This analysis provides a determination of the elastic mean free path within the aerogel. Measurements of the magnetization of the superfluid phase in the same aerogel samples provide a test of the theory of pairbreaking and magnetic response of low-energy excitations in the 'dirty' B phase of {sup 3}He in aerogel. A consistent interpretation of the data for the spin-diffusion coefficient, magnetization, and superfluid transition temperature is obtained by including correlation effects in the aerogel density.

  7. The Triple Oxygen Isotopic Composition of High 3He/4He Mantle

    NASA Astrophysics Data System (ADS)

    Jackson, C.; Parman, S. W.; Starkey, N.; Greenwood, R.; Franchi, I.; Jackson, M. G.; Fitton, J. G.; Stewart, F. M.; Larsen, L. M.

    2015-12-01

    Measurements of Xe isotope ratios in ocean island basalts (OIB) suggest that Earth's mantle accreted heterogeneously, and that compositional remnants of accretion are sampled by modern, high-3He/4He OIB associated with the Icelandic and Samoan plumes [1]. If so, the high-3He/4He source may also have a distinct oxygen isotopic composition from the rest of the mantle. Here, we test if the major elements of the high-3He/4He source preserve any evidence of heterogeneous accretion using measurements of three oxygen isotopes on olivine from a variety of high-3He/4He OIB locations. To high precision, the ∆17O value of high-3He/4He olivines from Hawaii, Pitcairn, Baffin Island and Samoa, are indistinguishable from bulk mantle olivine (Δ17OBulk Mantle - Δ17OHigh 3He/4He olivine = -0.002 ± 0.004 (2 x SEM) ‰). Thus, there is no resolvable oxygen isotope evidence for heterogeneous accretion in the high-3He/4He source. Modelling of mixing processes indicates that if an early-forming, oxygen-isotope distinct mantle did exist, either the anomaly was extremely small, or the anomaly was homogenised away by later mantle convection. The δ18O values of olivine with the highest 3He/4He ratios from a variety of OIB locations have a relatively uniform composition (~5 ‰). This composition is intermediate to values associated with the depleted MORB mantle and the average mantle. Similarly, δ18O values of olivine from high-3He/4He OIB correlate with radiogenic isotope ratios of He, Sr, and Nd. Combined, this suggests that oxygen remains coupled to the more incompatible elements during melt production and migration and that the intermediate δ18O value is a feature of the mantle source. The processes responsible for the δ18O signature of high-3He/4He mantle are not certain, but δ18O-87Sr/86Sr correlations indicate that it may be connected to a predominance of a HIMU-like (high U/Pb) component or other moderate δ18O components recycled into the high-3He/4He source. [1] S

  8. Entrance and exit channel phenomena in d- and 3He-induced preequilibrium decay

    NASA Astrophysics Data System (ADS)

    Bissem, H. H.; Georgi, R.; Scobel, W.; Ernst, J.; Kaba, M.; Rao, J. Rama; Strohe, H.

    1980-10-01

    Activation techniques were used to measure more than 30 excitation functions for single and multiple nucleon and/or α particle emission for d+64,66Zn, 89Y with Ed=9-26 MeV and 3He+63,65Cu, 93Nb with E(3He)=10-44 MeV. The excitation functions are generally in agreement with the results of a combined equilibrium and preequilibrium hybrid model calculation applying initial exciton numbers n0=3 for d and n0=4 for 3He reactions. The composite system 66Ga has been produced via d+64Zn and 3He+63Cu at excitation energies between 22 and 36 MeV. An entrance channel dependence shows up in the yields for single p- and n-emission when compared in the double ratio R=[σ(3He, p)σ(3He, n)][σ(d, p)σ(d, n)]. It approaches a value of about 2, indicating enhanced p emission for the 3He-induced reaction. This value disagrees with the equilibrium isospin formalism and is best reproduced by initial particle exciton numbers n0p=n0n=1.5 for d and n0p=2.5, n0n=1.5 for 3He projectiles, indicating conservation of charge asymmetry in the entrance channel. Isomeric ratios have been measured for 89Y(d, 2n)89Zr and 93Nb(3He, xn)96-xTc (x=1, 2, 3). Calculations with a full statistical model fail to reproduce σgσm as well as σg and σm for reasonable values of the spin cutoff parameter. Inclusion of a preequilibrium decay mode improves the fit, in particular if the angular momentum depletion of the composite system due to preequilibrium decay is increased over that of the equilibrium decay at the same channel energy. NUCLEAR REACTIONS 64,66Zn, 89Y(d, xnypzα), Ed=9-26 MeV, 63,65Cu, 93Nb(3He, xnypzα), E3He=10-44 MeV, x<=4, y<=1, z<=2 measured σ(E) by activation, enriched targets. Statistical model analysis including preequilibrium decay, deduced reaction mechanism, charge asymmetry conservation, spin depletion.

  9. SU‐C‐105‐05: Reference Dosimetry of High‐Energy Electron Beams with a Farmer‐Type Ionization Chamber

    SciTech Connect

    Muir, B; Rogers, D

    2013-06-15

    Purpose: To investigate gradient effects and provide Monte Carlo calculated beam quality conversion factors to characterize the Farmer‐type NE2571 ion chamber for high‐energy reference dosimetry of clinical electron beams. Methods: The EGSnrc code system is used to calculate the absorbed dose to water and to the gas in a fully modeled NE2571 chamber as a function of depth in a water phantom. Electron beams incident on the surface of the phantom are modeled using realistic BEAMnrc accelerator simulations and electron beam spectra. Beam quality conversion factors are determined using calculated doses to water and to air in the chamber in high‐energy electron beams and in a cobalt‐60 reference field. Calculated water‐to‐air stopping power ratios are employed for investigation of the overall ion chamber perturbation factor. Results: An upstream shift of 0.3–0.4 multiplied by the chamber radius, r-cav, both minimizes the variation of the overall ion chamber perturbation factor with depth and reduces the difference between the beam quality specifier (R{sub 5} {sub 0}) calculated using ion chamber simulations and that obtained with simulations of dose‐to‐water in the phantom. Beam quality conversion factors are obtained at the reference depth and gradient effects are optimized using a shift of 0.2r-cav. The photon‐electron conversion factor, k-ecal, amounts to 0.906 when gradient effects are minimized using the shift established here and 0.903 if no shift of the data is used. Systematic uncertainties in beam quality conversion factors are investigated and amount to between 0.4 to 1.1% depending on assumptions used. Conclusion: The calculations obtained in this work characterize the use of an NE2571 ion chamber for reference dosimetry of high‐energy electron beams. These results will be useful as the AAPM continues to review their reference dosimetry protocols.

  10. The mean ionic charge of silicon in 3HE-rich solar flares

    NASA Technical Reports Server (NTRS)

    Luhn, A.; Klecker, B.; Hovestadt, E.; Moebius, E.

    1985-01-01

    Mean ionic charge of iron in 3He-rich solar flares and the average mean charge of Silicon for 23 #He-rich periods during the time interval from September 1978 to October 1979 were determined. It is indicated that the value of the mean charge state of Silicon is higher than the normal flare average by approximately 3 units and in perticular it is higher then the value predicted by resonant heating models for 3He-rich solar flares.

  11. Distal airways in humans: dynamic hyperpolarized 3He MR imaging--feasibility

    NASA Technical Reports Server (NTRS)

    Tooker, Angela C.; Hong, Kwan Soo; McKinstry, Erin L.; Costello, Philip; Jolesz, Ferenc A.; Albert, Mitchell S.

    2003-01-01

    Dynamic hyperpolarized helium 3 (3He) magnetic resonance (MR) imaging of the human airways is achieved by using a fast gradient-echo pulse sequence during inhalation. The resulting dynamic images show differential contrast enhancement of both distal airways and the lung periphery, unlike static hyperpolarized 3He MR images on which only the lung periphery is seen. With this technique, up to seventh-generation airway branching can be visualized. Copyright RSNA, 2003.

  12. A compact SEOP 3He neutron spin filter with AFP NMR

    NASA Astrophysics Data System (ADS)

    Ino, Takashi; Arimoto, Yasushi; Shimizu, Hirohiko M.; Sakaguchi, Yoshifumi; Sakai, Kenji; Kira, Hiroshi; Shinohara, Takenao; Oku, Takayuki; Suzuki, Jun-ichi; Kakurai, Kazuhisa; Chang, Lieh-Jeng

    2012-02-01

    We developed AFP NMR in an aluminum container for polarized noble gas nuclei. The radio frequency magnetic field inside the aluminum container was designed from computer simulations. The polarization loss by the AFP spin flip of 3He was measured to be as low as 3.8×10-4. With this technique, a compact in-situ polarizing 3He neutron spin filter with AFP NMR is demonstrated.

  13. A review of sup 3 He resources and acquisition for use as fusion fuel

    SciTech Connect

    Wittenberg, L.J.; Camerson, E.N.; Kulcinski, G.L.; Ott, S.H.; Santarius, J.F.; Sviatoslavsky, G.I.; Sviatoslavsky, I.N.; Thompson, H.E. . Fusion Technology Inst.)

    1992-07-01

    This paper reports that a combination of man-made and natural resources on earth could provide sufficient {sup 3}He fuel for the technological development of D-{sup 3}He fusion reactors. Helium exists in natural gas wells; however, at the current rate of natural gas usage, this resource would provide {lt}5 kg/yr of {sup 3}He. The radioactive decay of {sup 3}H produced in fission production reactors could yield 110 kg of {sup 3}He by the year 2000 if it were retained. Apparently, a large amount of {sup 3}He exists within the earth's mantle, but it is inaccessible. A significant quantity of {sup 3}He, which could be imported to supply a fusion power industry on earth for hundreds of years, exists on the moon. The solar wind has deposited {gt}1 million tonnes of {sup 3}He in the fine regolith that covers the surface of the moon. The presence of this solar wind gas was confirmed by analyses of the lunar regolith samples brought to earth. A strong correlation is noted between the helium retained and the TiO{sub 2} content of the regolith; consequently, remote-sensing data showing high-titanium-bearing soils in the lunar maria areas have been used to locate potentially rich sites for helium extraction. Surface photographs of Mare Tranquillitatis have shown that nearly 50% of this mare may be minable and capable of supplying {approximately}7100 tonnes of {sup 3}He. A mobile mining vehicle is proposed for use in the excavation of the soil and the release of the helium and other solar wind gases. The evolved gases would be purified by a combination of permeators and cryogenic techniques to provide a rich resource of H{sub 2}, helium, CO{sub 2}, H{sub 2}O, and N{sub 2}, followed by helium isotopic separation systems.

  14. Examining Particle Transport in Multi-Spacecraft 3He-Rich SEP Events

    NASA Astrophysics Data System (ADS)

    Cohen, Christina; Giacalone, Joe; Wiedenbeck, Mark E.; Mason, Glenn

    2015-04-01

    One of the surprising outcomes of recent multi-spacecraft studies of solar energetic particle (SEP) events is that small 3He-rich events can have large longitudinal spans. Although their solar source region is typically quite small, individual 3He-rich SEP events have been detected by near-1AU spacecraft separated by as much as 136 degrees. Although bundles of magnetic field lines can expand from small areas (5-10 degrees) at the photosphere to larger (~60 degrees) regions at 2.5 RS, this is not sufficient to explain the wide 3He-rich events observed by well-separated spacecraft. One possible explanation of these events involves a combination of particle diffusion in the inner heliosphere and field line co-rotation with the Sun. We have examined the onsets of the elevated 3He intensities at ACE and both STEREO spacecraft for several wide 3He-rich SEP events. The timing of these onsets has been compared to that predicted by a diffusive transport model for particle propagation. These results and their implications for the conditions conducive to creating wide 3He-rich SEP events are discussed.

  15. Pomeranchuk cell for hyperpolarized 3He based on the brute force method

    NASA Astrophysics Data System (ADS)

    Makino, Seiji; Tanaka, Masayoshi; Ueda, Kunihiro; Fujiwara, Mamoru; Fujimura, Hisako; Yosoi, Masaru; Ohta, Takeshi; Frossati, Giorgio; de Waard, Arlette; Rouille, Gerard

    2014-09-01

    MRI (Magnetic Resonance Imaging) has been used for the medical diagnosis as a radiation-free imaging equipment. Since the proton has been mainly used for medical MRI, usefulness has been rather restrictive. As an example for expanding the range of applicability, MRI with hyperpolarized 3He gas has been used for the lung disease. Here, ``hyperpolarized'' means ``polarized higher than the thermal equilibrium polarization.'' For producing a large amount of hyperpolarized 3He gas at a time, we have been developing a hyperpolarization technique based on the brute force method which uses an ultralow temperature of a few mK and a strong magnetic field around 17 T in combination with the principle of the Pomeranchuk cooling. The Pomeranchuk cell made with non-metallic materials of small heat capacity is attached to the 3He/4He dilution refrigerator using a sintered silver allowing large heat conduction. After the sensors to monitor the temperature and pressure of 3He are calibrated and the Pomeranchuk cell is constructed, the system is tested. Then, the solidification of 3He and the measurement of NMR (Nuclear Magnetic Resonance) signals of 3He under the magnetic field of 17 T are carried out. The current status is reported in this talk.

  16. Optimised adiabatic fast passage spin flipping for 3He neutron spin filters

    NASA Astrophysics Data System (ADS)

    McKetterick, T. J.; Boag, S.; Stewart, J. R.; Frost, C. D.; Skoda, M. W. A.; Parnell, S. R.; Babcock, E.

    2011-06-01

    We describe here a method of performing adiabatic fast passage (AFP) spin flipping of polarized 3He used as a neutron spin filter (NSF) to polarize neutron beams. By reversing the spin states of the 3He nuclei the polarization of a neutron beam can be efficiently reversed allowing for the transmission of a neutron beam polarized in either spin state. Using an amplitude modulated frequency sweep lasting 500 ms we can spin flip a polarized 3He neutron spin filter with only 1.8×10-5 loss in 3He polarization. The small magnetic fields (10-15 G) used to house neutron spin filters mean the 3He resonant frequencies are low enough to be generated using a computer with a digital I/O card. The versatility of this systems allows AFP to be performed on any beamline or in any laboratory using 3He neutron spin filters and polarization losses can be minimised by adjusting sweep parameters.

  17. Thermal resistance between liquid /sup 3/He and copper potassium tutton salt

    SciTech Connect

    Fujii, Y.; Shigi, T.

    1987-01-01

    The thermal resistance between liquid /sup 3/He and copper potassium tutton salt (CPS) has been measured through its magnetic ordering temperature (T/sub c/ = 29.6 mK). The thermal resistance R for pure /sup 3/He has a broad minimum near 60 mK and increases continuously through T/sub c/ with decreasing temperature, except for a dip at T/sub c/. Below T/sub c/, R is proportional to T/sup -1.5/. Effects of /sup 4/He coating have been studied by stepwise addition of /sup 4/Me into liquid /sup 3/He. The thermal resistance increased drastically for the liquid containing 150 ppm/sup 4/Me and more for 95% /sup 4/He. By sudden depressurization of the liquid /sup 3/He containing 480 ppm /sup 4/He, a considerable decrease of R was observed. Since R for pure /sup 3/He was much smaller than the calculated Kapitza resistance, the present experimental results indicate the existence of surface magnetic coupling between liquid /sup 3/He and CPS.

  18. Compressing Spin-Polarized 3He With a Modified Diaphragm Pump

    PubMed Central

    Gentile, T. R.; Rich, D. R.; Thompson, A. K.; Snow, W. M.; Jones, G. L.

    2001-01-01

    Nuclear spin-polarized 3He gas at pressures on the order of 100 kPa (1 bar) are required for several applications, such as neutron spin filters and magnetic resonance imaging. The metastability-exchange optical pumping (MEOP) method for polarizing 3He gas can rapidly produce highly polarized gas, but the best results are obtained at much lower pressure (~0.1 kPa). We describe a compact compression apparatus for polarized gas that is based on a modified commercial diaphragm pump. The gas is polarized by MEOP at a typical pressure of 0.25 kPa (2.5 mbar), and compressed into a storage cell at a typical pressure of 100 kPa. In the storage cell, we have obtained 20 % to 35 % 3He polarization using pure 3He gas and 35 % to 50 % 3He polarization using 3He-4He mixtures. By maintaining the storage cell at liquid nitrogen temperature during compression, the density has been increased by a factor of four. PMID:27500044

  19. Tritium/3He measurements in young groundwater: Progress in applications to complex hydrogeological systems

    USGS Publications Warehouse

    Schlosser, P.; Shapiro, S.D.; Stute, M.; Plummer, N.

    2000-01-01

    Tritium/3He dating has been applied to many problems in groundwater hydrology including, for example, determination of circulation patterns, mean residence times, recharge rates, or bank infiltration. Here, we discuss recent progress in the application of the tritium/3He dating method to sites with complex hydrogeological settings. Specifically, we report on tritium/3He dating at sites with (a) river infiltration into the basaltic fractured rock aquifer of the Eastern Snake River Plain, and (b) river infiltration through sinkholes into the karstic limestone Upper Floridian aquifer near Valdosta, Georgia.Tritium/3He dating has been applied to many problems in groundwater hydrology including, for example, determination of circulation patterns, mean residence times, recharge rates, or bank infiltration. Here, we discuss recent progress in the application of the tritium/3He dating method to sites with complex hydrogeological settings. Specifically, we report on tritium/3He dating at sites with (a) river infiltration into the basaltic fractured rock aquifer of the Eastern Snake River Plain, and (b) river infiltration through sinkholes into the karstic limestone Upper Floridian aquifer near Valdosta, Georgia.

  20. Bakeout Chamber Within Vacuum Chamber

    NASA Technical Reports Server (NTRS)

    Taylor, Daniel M.; Soules, David M.; Barengoltz, Jack B.

    1995-01-01

    Vacuum-bakeout apparatus for decontaminating and measuring outgassing from pieces of equipment constructed by mounting bakeout chamber within conventional vacuum chamber. Upgrade cost effective: fabrication and installation of bakeout chamber simple, installation performed quickly and without major changes in older vacuum chamber, and provides quantitative data on outgassing from pieces of equipment placed in bakeout chamber.

  1. Terrestrial cosmogenic 3He: where are we 30 years after its discovery?

    NASA Astrophysics Data System (ADS)

    Blard, Pierre-Henri; Pik, Raphaël; Farley, Kenneth A.; Lavé, Jérôme; Marrocchi, Yves

    2016-04-01

    It is now 30 years since cosmogenic 3He has been detected for the first time in a terrestrial sample (Kurz, 1986). 3He is now a widely used geochemical tool in many fields of Earth sciences: volcanology, tectonics, paleoclimatology. 3He has the advantage to have a high "production rate" to "detection limit" ratio, allowing surfaces as young as hundred of years to be dated. Although its nuclear stability implies several limitations, it moreover represents a useful alternative to 10Be in mafic environments. This contribution is a review of the progresses that have been accomplished since this discovery, and discuss strategies to improve both the accuracy and the precision of this geochronometer. 1) Measurement of cosmogenic 3He Correction of magmatic 3He. To estimate the non-cosmogenic magmatic 3He, Kurz (1986) invented a two steps method involving crushing of phenocrysts (to analyze the isotopic ratio of the magmatic component), followed by a subsequent melting of the sample, to extract the remaining components, including the cosmogenic 3He: 3Hec = 3Hemelt ‑4Hemelt x (3He/4He)magmatic (1) Several studies suggested that the preliminary crushing may induce a loss of cosmogenic 3He (Hilton et al., 1993; Yokochi et al., 2005; Blard et al., 2006), implying an underestimate of the cosmogenic 3He measurement. However, subsequent work did not replicate these observations (Blard et al., 2008; Goerhing et al., 2010), suggesting an influence of the used apparatus. An isochron method (by directly melting several phenocrysts aliquots) is an alternative to avoid the preliminary crushing step (Blard and Pik, 2008). Atmospheric contamination. Protin et al. (in press) provides robust evidences for a large and irreversible contamination of atmospheric helium on silicate surfaces. This unexpected behavior may reconcile the contrasted observations about the amplitude of crushing loss. This undesirable atmospheric contamination is negligible if grain fractions smaller than 150 mm are

  2. Proton beam monitor chamber calibration.

    PubMed

    Gomà, C; Lorentini, S; Meer, D; Safai, S

    2014-09-01

    The first goal of this paper is to clarify the reference conditions for the reference dosimetry of clinical proton beams. A clear distinction is made between proton beam delivery systems which should be calibrated with a spread-out Bragg peak field and those that should be calibrated with a (pseudo-)monoenergetic proton beam. For the latter, this paper also compares two independent dosimetry techniques to calibrate the beam monitor chambers: absolute dosimetry (of the number of protons exiting the nozzle) with a Faraday cup and reference dosimetry (i.e. determination of the absorbed dose to water under IAEA TRS-398 reference conditions) with an ionization chamber. To compare the two techniques, Monte Carlo simulations were performed to convert dose-to-water to proton fluence. A good agreement was found between the Faraday cup technique and the reference dosimetry with a plane-parallel ionization chamber. The differences-of the order of 3%-were found to be within the uncertainty of the comparison. For cylindrical ionization chambers, however, the agreement was only possible when positioning the effective point of measurement of the chamber at the reference measurement depth-i.e. not complying with IAEA TRS-398 recommendations. In conclusion, for cylindrical ionization chambers, IAEA TRS-398 reference conditions for monoenergetic proton beams led to a systematic error in the determination of the absorbed dose to water, especially relevant for low-energy proton beams. To overcome this problem, the effective point of measurement of cylindrical ionization chambers should be taken into account when positioning the reference point of the chamber. Within the current IAEA TRS-398 recommendations, it seems advisable to use plane-parallel ionization chambers-rather than cylindrical chambers-for the reference dosimetry of pseudo-monoenergetic proton beams. PMID:25109620

  3. Modeling 3H-3He Gas-Liquid Phase Transport for Interpretation of Groundwater Age

    NASA Astrophysics Data System (ADS)

    Carle, S. F.; Esser, B.; Moran, J. E.

    2009-12-01

    California’s Groundwater Ambient Monitoring and Assessment (GAMA) Program has measured many hundreds of tritium (3H) and helium-3 (3He) concentrations in well water samples to derive estimates of groundwater age at production and monitoring wells in California basins. However, a 3H-3He age differs from an ideal groundwater age tracer in several respects: (1) the radioactive decay of 3H results in the accumulation of 3He being first-order with respect to 3H activity (versus a zero-order age-mass accumulation process for an ideal tracer), (2) surface concentrations of 3H as measured in precipitation over the last several decades have not been uniform, and (3) the 3H-3He “clock” begins at the water table and not at the ground surface where 3H source measurements are made. To better understand how these non-idealities affect interpretation of 3H-3He apparent groundwater age, we are modeling coupled gas-liquid phase flow and 3H-3He transport including processes of radiogenic decay, phase equilibrium, and molecular diffusion for water, air, 3H, and 3He components continuously through the vadose zone and saturated zone. Assessment of coupled liquid-gas phase processes enables consideration of 3H-3He residence time and dispersion within the vadose zone, including partitioning of tritiogenic 3He to the gas phase and subsequent diffusion into the atmosphere. The coupled gas-liquid phase modeling framework provides direct means to compare apparent 3H-3He age to ideal mean or advective groundwater ages for the same groundwater flow conditions. Examples are given for common groundwater flow systems involving areal recharge, discharge to streams or long-screened wells, and aquifer system heterogeneity. The Groundwater Ambient Monitoring and Assessment program is sponsored by the California State Water Resources Control Board and carried out in cooperation with the U.S. Geological Survey. This work was performed under the auspices of the U.S. Department of Energy by

  4. Photodisintegration of /sup 3/H and /sup 3/He. [Threshold to 25 MeV

    SciTech Connect

    Faul, D.D.

    1980-09-01

    The photoneutron cross sections for /sup 3/H and /sup 3/He have been measured from threshold to approx. 25 MeV with monoenergetic photons from the annihilation in flight of fast positrons at the LLL Electron-Positron Linear Accelerator facility. These reactions include the two-body breakup of /sup 3/H and the three-body breakup of both /sup 3/H and /sup 3/He; these measurements for /sup 3/H are the first to span the energy region across the peaks of the cross sections. An efficient BF/sub 3/-tube-and-paraffin neutron detector and high-pressure gaseous samples of several moles each (the activity of the /sup 3/H sample was approx. 200,000 Ci) were employed in these measurements. Measurements on /sup 16/O and /sup 2/H also were performed to verify the absolute cross-section scale. The results, when compared with each other and with results for the two-body breakup cross section for /sup 3/He from the literature, show that the two-body breakup cross sections for /sup 3/H and /sup 3/He have nearly the same shape, but the one for /sup 3/He lies lower in magnitude; the three-body breakup cross section for /sup 3/He lies higher in magnitude and is broader in the peak region and also rises less sharply from threshold than that for /sup 3/H; and these measured differences between the cross sections for the breakup modes largely compensate in their sum, so that the total photon absorption cross sections for /sup 3/H and /sup 3/He are nearly the same in both size and shape at energies near and above their peaks. Theoretical results from the literature disagree with the experimental results to a certain extent over the entire photon-energy region for which the photoneutron cross sections were measured. 50 figures, 7 tables.

  5. A new method for determining the 3He/4He ratio in the local interstellar medium

    NASA Astrophysics Data System (ADS)

    Lemoine, M.; Vidal-Madjar, A.; Ferlet, R.

    1993-06-01

    We propose here an original method for estimating the 3He/4 Heratio in the local diffuse interstellar medium at a low cost from an observational point of view. The main idea is to measure the shift in radial velocity of the 4He λ537Å and λ584Å lines due to the presence of 3He in the red wing of these lines, and to compare the observed shift to the shifts obtained through numerical simulations for different 3He/4He ratios. We performed such simulations in order to reveal the efficiency of this method, using typical astrophysical conditions and instrumental parameters corresponding to the Lyman-FUSE mission. We find that this method should yield the 3He/4He ratio with a 1 σ uncertainty ˜50% at a spectral resolving power R=30 000 and a signal-to-noise ratio S/N=50. This method thus appears more adapted to a forehand estimation of the interstellar 3He/4He ratio than the standard profile fitting method, which should yield a 1 σ uncertainty of 10% at R=30 000 and S/N ≃ 290 (Hurwitz & Bowyer, t985). Finally, our method should be able to settle the evolutionary status of 3He if 3He has been significantly enhanced or depleted in the last 4.6 Gyr. Combined with the measurement of the deuterium abundance on the same line of sight (already programmed on HST), this might yield very important constraint on Big-Bang nucleosynthesis consistency.

  6. SU-E-T-625: Use and Choice of Ionization Chambers for the Commissioning of Flattened and Flattening-Filter-Free Photon Beams: Determination of Recombination Correction Factor (ks)

    SciTech Connect

    Stucchi, C; Mongioj, V; Carrara, M; Pignoli, E; Bonfantini, F; Bresolin, A

    2014-06-15

    Purpose: To evaluate the recombination effect for some ionization chambers to be used for linacs commissioning for Flattened Filter (FF) and Flattening Filter Free (FFF) photon beams. Methods: A Varian TrueBeam linac with five photon beams was used: 6, 10 and 15 MV FF and 6 and 10 MV FFF. Measurements were performed in a water tank and in a plastic water phantom with different chambers: a mini-ion chamber (IC CC01, IBA), a plane-parallel ion chamber (IC PPC05, IBA) and two Farmer chambers (NE2581 and FPC05-IBA). Measurement conditions were Source- Surface Distance of 100 cm, two field sizes (10x10 and 40x40 cm2) and five depths (1cm, maximum buildup, 5cm, 10cm and 20cm). The ion recombination factors (kS), obtained from the Jaffe's plots (voltage interval 50-400 V), were evaluated at the recommended operating voltage of +300V. Results: Dose Per Pulse (DPP) at dmax was 0.4 mGy/pulse for FF beams, 1.0 mGy/pulse and 1.9 mGy/pulse for 6MV and 10 MV FFF beams respectively. For all measurement conditions, kS ranged between 0.996 and 0.999 for IC PPC05, 0.997 and 1.008 for IC CC01. For the FPC05 IBA Farmer IC, kS varied from 1.001 to 1.011 for FF beams, from 1.004 to 1.015 for 6 MV FFF and from 1.009 to 1.025 for 10 MV FFF. Whereas, for NE2581 IC the values ranged from 1.002 to 1.009 for all energy beams and measurement conditions. Conclusion: kS depends on the chamber volume and the DPP, which in turn depends on energy beam but is independent of dose rate. Ion chambers with small active volume can be reliably used for dosimetry of FF and FFF beams even without kS correction. On the contrary, for absolute dosimetry of FFF beams by Farmer ICs it is necessary to evaluate and apply the kS correction. Partially supported by Lega Italiana Lotta contro i Tumori (LILT)

  7. A record of the extraterrestrial 3He flux through the Late Cretaceous

    NASA Astrophysics Data System (ADS)

    Farley, K. A.; Montanari, A.; Coccioni, R.

    2012-05-01

    Late Cretaceous (100-73 Ma) pelagic limestones were measured for helium concentration and isotopic composition to characterize the interplanetary dust flux using 3He as a tracer. In the Bottaccione section near Gubbio, Italy, three intervals of elevated 3He concentration were detected: K1 in the Campanian stage at ˜79 Ma, K2 in the Santonian stage at ˜85 Ma, and K3 in the Turonian stage at ˜91 Ma. All three of these episodes are associated with high 3He/4He and 3He/non-carbonate ratios, consistent with their derivation from an enhanced extraterrestrial 3He flux rather than decreased carbonate sedimentation or dissolution. While K2 is modest in magnitude and duration and thus is of limited significance, K1 and K3 are each identified by a few myr interval with an ˜4-fold enhancement in mean 3He flux compared with pre-event levels. Samples from ODP Hole 762C in the Indian Ocean spanning both K2 and K3 (93-83 Ma) confirm the presence of a peak in the Turonian stage, suggesting that K3 is a global event. The K1 and K3 3He events are similar in most respects to the two peaks previously detected in the Cenozoic, suggesting a similar origin. These have been attributed to a major asteroid collision in the Late Miocene and to a shower of either comets or asteroids in the Late Eocene. Based on the age and temporal evolution of K1, we suggest that it most likely records the collision which produced the Baptistina asteroid family independently dated at ˜80 Ma. The K3 event is less easily explained. It is characterized by an unusually spiky and erratic temporal progression, suggesting an unusual abundance of very 3He rich particles not previously seen in the sedimentary 3He record. We suggest this episode arises either from a comet shower or from an asteroid shower possibly associated with dust-producing lunar impacts.

  8. Results on Double-polarization Asymmetries in Quasielastic Scattering from Polarized 3He

    NASA Astrophysics Data System (ADS)

    Sulkosky, Vincent A.

    2016-03-01

    The 3He nucleus has become extremely important in the investigation of the neutron's spin structure. When polarized, 3He acts as an effective polarized neutron target and hence facilitates our understanding of the neutron's internal structure. However, to be used in this manner, our understanding of the internal structure of 3He is of extreme importance. As the precision of experiments has improved, the extraction of polarized neutron information from 3He leads to an ever larger share of the systematic uncertainty for these experiments. In these proceedings, I present a precise measurement of beam-target asymmetries in the {}^3overrightarrow {He} (e,e'd) and {}^3overrightarrow {He} (e,e'p) reactions. The former process is a uniquely sensitive probe of hadron dynamics in 3He and the structure of the underlying electromagnetic currents. The measurements have been performed around the quasi-elastic peak at Q2 = 0.25 (GeV/c)2 and 0.35 (GeV/c)2 for recoil momenta up to 270 MeV/c. The experimental apparatus, analysis and results were presented together with a comparison to state-of-the art Faddeev calculations.

  9. Interspecies Ion Diffusion Studies using DT, DT(3He), and DT(H) Implosions

    NASA Astrophysics Data System (ADS)

    Kim, Y.; Herrmann, H. W.; Schmitt, M. J.; Kagan, G.; McEvoy, A. M.; Hoffman, N. M.; Gales, S.; Leatherland, A.; Gatu Johnson, M.; Frenje, J.; Glevov, V. Yu; Forrest, C.

    2015-11-01

    Anomalous ICF yield degradation has been observed from gas fills containing mixtures (i.e., D(3He), DT(3He), D(Ar), and even DT). Interspecies ion diffusion theory has been suggested as a possible cause resulting from gradient-driven diffusion (i.e., pressure, electric potential, and temperature) which forces lower mass ions away from core and higher mass ions toward core. The theory predicts hydrogen addition to deuterium or tritium should result in increased yield compared to expected yield, which is opposite to 3He addition. At Omega laser facility, we have tested hydro-equivalent fills of DT, DT(3He), and DT(H) with the assumption that same fuel mass and particle pressure will provide identical convergence. Preliminary results verify a factor of 2 yield reduction relative to scaling when 3He added to DT. At DT(H) case, however, no significant yield degradation or a slight yield enhancement was observed which agrees with the interspecies ion diffusion theory. Detailed experiment results and simulation are needed to confirm the initial observation.

  10. 3He-rich SEP events observed by STEREO-A

    NASA Astrophysics Data System (ADS)

    Bućík, R.; Mall, U.; Korth, A.; Mason, G. M.; Gómez-Herrero, R.

    2013-06-01

    Using the SIT (Suprathermal Ion Telescope) instrument on STEREO-A we have examined the abundance of the rare isotope 3He during the rising activity phase of solar cycle 24 between January 2010 and December 2011. We have identified six solar energetic particle (SEP) events with enormous abundance enhancements of 3He(3He/4He>1). The events were short lasting, typically ~ 0.5 - 1 day and most of them occurred in association with high-speed solar wind streams and corotating interaction regions. With one exception the events were not associated with ~ 100 keV solar electron intensity increases. The events showed also enhanced NeS/O and Fe/O ratios. The solar images indicate that the events were generally associated with the active regions located near a coronal hole.

  11. Spin Correlation Parameter Cyy of p + 3He Elastic Backward Scattering at Intermediate Energy

    NASA Astrophysics Data System (ADS)

    Shimizu, Y.; Hatanaka, K.; Adachi, T.; Itoh, K. F. K.; Kawabata, T.; Kudoh, T.; Ohira, H. M. H.; Okamura, H.; Sagara, K.; Sasamoto, Y. S. Y.; Yoshida, Y. S. H. P.; Suda, K.; Tomiyama, Y. T. A. T. M.; Uesaka, M. U. T.; Wakasa, T.; Wakui, T.

    2005-08-01

    It is possible to use nucleon-nucleus scattering as a probe of the spin structure of nuclei, since target related observables are extremely sensitive to small spin-dependent parts of the target wave function. In addition, one can gain information about the nucleon-nucleus reaction mechanism, the spin dependence of the nucleon-nucleon interaction in the nuclear medium, and off-shell behavior of the nucleon-nucleon amplitudes. For 3He(p,3He)p elastic backward scattering (EBS), only a small amount of data exists for the differential cross-section and none exists for spin-dependent observables. We have developed a spin-exchange polarised 3He target and measured the spin correlation parameter Cyy at 200, 300, and 400 MeV.

  12. Spin Correlation Parameter Cyy of p + 3He Elastic Backward Scattering at Intermediate Energy

    NASA Astrophysics Data System (ADS)

    Shimizu, Y.; Hatanaka, K.; Kobushkin, A. P.; Adachi, T.; Fujita, K.; Itoh, K.; Kawabata, T.; Kudoh, T.; Matsubara, H.; Ohira, H.; Okamura, H.; Sagara, K.; Sakemi, Y.; Sasamoto, Y.; Shimbara, Y.; Yoshida, H. P.; Suda, K.; Tameshige, Y.; Tamii, A.; Tomiyama, M.; Uchida, M.; Uesaka, T.; Wakasa, T.; Wakui, T.

    2007-01-01

    It is possible to use nucleon-nucleus scattering as a probe of the spin structure of the nuclei since target related observables are extremely sensitive to spin dependent parts of the target wave function. In addition, one can gain information about the nucleon-nucleus reaction mechanism, the spin dependent nucleon-nucleon interaction in the nuclear medium, and off-shell behavior of the nucleon-nucleon amplitudes. For 3He(p,3He)p elastic backward scattering, only small amount of data points exist for the differential cross section and no data exist for spin dependent observables. We developed a spin exchange type polarized 3He target and measured the spin correlation parameter Cyy at 200, 300, and 400 MeV.

  13. Use of .sup.3 He.sup.30 + ICRF minority heating to simulate alpha particle heating

    DOEpatents

    Post, Jr., Douglass E.; Hwang, David Q.; Hovey, Jane

    1986-04-22

    Neutron activation due to high levels of neutron production in a first heated deuterium-tritium plasma is substantially reduced by using Ion Cyclotron Resonance Frequency (ICRF) heating of energetic .sup.3 He.sup.++ ions in a second deuterium-.sup.3 He.sup.++ plasma which exhibit an energy distribution and density similar to that of alpha particles in fusion reactor experiments to simulate fusion alpha particle heating in the first plasma. The majority of the fast .sup.3 He.sup.++ ions and their slowing down spectrum can be studied using either a modulated hydrogen beam source for producing excited states of He.sup.+ in combination with spectrometers or double charge exchange with a high energy neutral lithium beam and charged particle detectors at the plasma edge. The maintenance problems thus associated with neutron activation are substantially reduced permitting energetic alpha particle behavior to be studied in near term large fusion experiments.

  14. Heavy-baryon chiral perturbation theory approach to thermal neutron capture on {sup 3}He

    SciTech Connect

    Lazauskas, Rimantas; Park, Tae-Sun

    2011-03-15

    The cross section for radiative thermal neutron capture on {sup 3}He ({sup 3}He+n{yields}{sup 4}He+{gamma}; known as the hen reaction) is calculated based on heavy-baryon chiral perturbation theory. The relevant M1 operators are derived up to next-to-next-to-next-to-leading order (N{sup 3}LO). The initial and final nuclear wave functions are obtained from the rigorous Faddeev-Yakubovski equations for five sets of realistic nuclear interactions. Up to N{sup 3}LO, the M1 operators contain two low-energy constants, which appear as the coefficients of nonderivative two-nucleon contact terms. After determining these two constants using the experimental values of the magnetic moments of the triton and {sup 3}He, we carry out a parameter-free calculation of the hen cross section. The results are in good agreement with the data.

  15. A System for Open-Access 3He Human Lung Imaging at Very Low Field

    PubMed Central

    RUSET, I.C.; TSAI, L.L.; MAIR, R.W.; PATZ, S.; HROVAT, M.I.; ROSEN, M.S.; MURADIAN, I.; NG, J.; TOPULOS, G.P.; BUTLER, J.P.; WALSWORTH, R.L.; HERSMAN, F.W.

    2010-01-01

    We describe a prototype system built to allow open-access very-low-field MRI of human lungs using laser-polarized 3He gas. The system employs an open four-coil electromagnet with an operational B0 field of 4 mT, and planar gradient coils that generate gradient fields up to 0.18 G/cm in the x and y direction and 0.41 G/cm in the z direction. This system was used to obtain 1H and 3He phantom images and supine and upright 3He images of human lungs. We include discussion on challenges unique to imaging at 50 –200 kHz, including noise filtering and compensation for narrow-bandwidth coils. PMID:20354575

  16. Tritium production, management and its impact on safety for a D- sup 3 He fusion reactor

    SciTech Connect

    Sze, D.K. ); Herring, S. ); Sawan, M. )

    1991-11-01

    About three percent of the fusion energy produced by a D-{sup 3}He reactor is in the form of neutrons. Those neutrons are generated by D-D and D-T reactions, with the tritium produced by the D-D fusion. The neutrons will react with structural steel, deuterium, {sup 3}He and shielding material to produce tritium. About half of the tritium generated by the D-D reaction will not burn in the plasma and will exit as a part of the plasma exhaust. Thus, there is enough tritium produced in a D-{sup 3}He reactor and careful management will be required. The tritium produced in the shield and plasma can be managed with an acceptable effect on cost and safety. 3 refs., 2 figs., 3 tabs.

  17. Phase Diagram for 3He Films on Boron Nitride: NMR Studies

    NASA Astrophysics Data System (ADS)

    Tang, Yibing; Sullivan, Neil

    2014-03-01

    Recent studies of the thermodynamic properties of 3He films on graphite have revealed the existence of a previously undetected self-bound liquid phase at low density coverages. We report the results of NMR relaxation time studies for 3He adsorbed on hexagonal boron nitride designed to explore the dynamics of the adsorbed 3He atoms in order to identify the phase boundaries as a function of temperature. A steep thermally activated temperature dependence is observed at high temperatures (T > 2 . 6) K, followed by a linear dependence for 0 . 77 < T < 2 . 6 K. The linear dependence is consistent with that expected for thermal diffusion in the self-bound liquid state. The research was supported in part by a grant from the National Science Foundation, DMR-1303599.

  18. The Effect Of Neutron Attenuation On Power Deposition In Nuclear Pumped 3He-Lasers

    NASA Astrophysics Data System (ADS)

    Çetin, Füsun

    2007-04-01

    Nuclear-pumped lasers (NPLs) are driven by the products of nuclear reactions and directly convert the nuclear energy to directed optical energy. Pumping gas lasers by nuclear reaction products has the advantage of depositing large energies per reaction. The need for high laser power output implies high operating pressure. In the case of volumetric excitation by 3He(n, p)3H reactions, however, operation at high pressure (more than a few atm) causes excessive neutron attenuation in the 3He gas. This fact adversely effects on energy deposition and, hence, laser output power and beam quality. Here, spatial and temporal variations of neutron flux inside a closed 3He -filled cylindrical laser tube have been numerically calculated for various tube radii and operating pressures by using a previously reported dynamic model for energy deposition. Calculations are made by using ITU TRIGA Mark II Reactor as the neutron source. The effects of neutron attenuation on power deposition are examined.

  19. Comparative study of nuclear effects in polarized electron scattering from 3He

    DOE PAGESBeta

    Ethier, Jacob James; Melnitchouk, Wally

    2013-11-04

    We present a detailed analysis of nuclear effects in inclusive electron scattering from polarized 3He nuclei for polarization asymmetries, structure functions and their moments, both in the nucleon resonance and deep-inelastic regions. We compare the results of calculations within the weak binding approximation at finite Q2 with the effective polarization ansatz often used in experimental data analyses, and explore the impact of Δ components in the nuclear wave function and nucleon off-shell corrections on extractions of the free neutron structure. Using the same framework we also make predictions for the Q2 dependence of quasielastic scattering from polarized 3He, data onmore » which can be used to constrain the spin-dependent nuclear smearing functions in 3He.« less

  20. Green's function theory for the Cheng-Schick model of 3He-4He mixtures

    NASA Astrophysics Data System (ADS)

    Siemann, R. P.; Boukahil, A.; Huber, D. L.

    2014-08-01

    In this paper, we outline a theory for the thermodynamic properties of 3He-4He mixtures in the neighborhood of the critical line and the tricritical point (TCP). The theory utilizes the Cheng-Schick (CS) lattice gas model where both the 3He and 4He atoms are treated as quantum particles on a lattice. The analysis is based on Green's function approach. Results are presented for the ordering susceptibility and the thermal averages of the occupation numbers of 3He and 4He atoms. We derive a self-consistent equation for the ordering susceptibility and use it to calculate the critical line and locate the TCP. Our findings are compared with the predictions obtained from high temperature series expansions, mean field theory and the random phase approximation (RPA).

  1. A Short History of the Theory and Experimental Discovery of Superfluidity in 3He

    NASA Astrophysics Data System (ADS)

    Brinkman, W. F.

    I discuss the development of the theory and experiments on superfluid 3He. After the discovery of superfluidity in 3He by Osheroff, Richardson and Lee, Phil Anderson quickly recruited Doug Osheroff to come to Bell Labs and set up a dilution fridge to continue his experiments. One of the mysteries at that time was how the high-temperature A-phase, which has a gapless excitation spectrum, could be stabilized relative to the fully gapped, lower temperature B-phase. I explain how Phil Anderson and I developed the spin fluctuation theory of the A-phase of superfluid 3He which accounted for its stability, leading to the Anderson-Brinkman-Morel (ABM) theory of the superfluid A-phase...

  2. Progress Towards the Detection of Faraday Rotation on Spin Polarized 3He

    NASA Astrophysics Data System (ADS)

    Abney, Joshua; Broering, Mark; Korsch, Wolfgang

    2016-05-01

    Off-resonance Faraday rotation can offer a method to measure the nuclear spin optical rotation of the 3 He nucleus and gain access to new information about the atomic polarizability of the Helium atom. The interaction of the polarization state of light with the nuclear spin of the helium atom is very weak and has never been detected. A sensitive triple modulation technique has been developed which can detect the expected rotation angle on the order of 100 nrad. Once a Faraday rotation signal is observed, the next step is to separate the magnetic and electric contributions to the rotation by utilizing their different frequency dependencies. Recent studies involved optimizing several parameters which impact 3 He target polarization. Progress towards detecting nuclear spin optical rotation on 3 He will be reported. This research is supported by DOE Grant DE-FG02-99ER41101.

  3. Asymmetries in electron-induced breakup of polarized {sup 3}He

    SciTech Connect

    Sirca, S.

    2011-10-24

    The Jefferson Lab Experiment E05-102 'Measurement of A{sub x}{sup '} and A{sub z}{sup '} asymmetries in the quasi-elastic {sup 3}He(e,e'd) reaction' was performed in Hall A in 2009. The main physics motivation of the experiment was to investigate the effects of small components of the {sup 3}He ground-state wave-function by a simultaneous measurement of double-polarization asymmetries in quasi-elastic kinematics for three exclusive channels, (e,e'd), (e,e'p), and (e,e'n), at almost identical momentum transfers, as well as for (e,e'). This experiment will help map the spin structure of the {sup 3}He nucleus onto the picture of the ''free'' polarized neutron. As such, it is of great relevance to the polarized-neutron programs at Jefferson Lab and beyond.

  4. The Effect Of Neutron Attenuation On Power Deposition In Nuclear Pumped 3He-Lasers

    SciTech Connect

    Cetin, Fuesun

    2007-04-23

    Nuclear-pumped lasers (NPLs) are driven by the products of nuclear reactions and directly convert the nuclear energy to directed optical energy. Pumping gas lasers by nuclear reaction products has the advantage of depositing large energies per reaction. The need for high laser power output implies high operating pressure. In the case of volumetric excitation by 3He(n, p)3H reactions, however, operation at high pressure (more than a few atm) causes excessive neutron attenuation in the 3He gas. This fact adversely effects on energy deposition and, hence, laser output power and beam quality. Here, spatial and temporal variations of neutron flux inside a closed 3He -filled cylindrical laser tube have been numerically calculated for various tube radii and operating pressures by using a previously reported dynamic model for energy deposition. Calculations are made by using ITU TRIGA Mark II Reactor as the neutron source. The effects of neutron attenuation on power deposition are examined.

  5. Double-Cell Geometry for 129Xe/3He Co-Magnetometry

    NASA Astrophysics Data System (ADS)

    Ohtomo, Yuichi; Ichikawa, Yuichi; Sato, Tomoya; Sakamoto, Yu; Kojima, Shuichiro; Suzuki, Takahiro; Shirai, Hazuki; Chikamori, Masatoshi; Hikota, Eri; Miyatake, Hirokazu; Nanao, Tsubasa; Suzuki, Kunifumi; Tsuchiya, Masato; Inoue, Takeshi; Furukawa, Takeshi; Yoshimi, Akihiro; Bidinosti, Christopher P.; Ino, Takashi; Ueno, Hideki; Matsuo, Yukari; Fukuyama, Takeshi; Asahi, Koichiro

    Comagnetometers play a key role in EDM experiments. They allow one to quantify, and subsequently correct for, any long-term drifts of the external magnetic field. In order to improve the performance of the 3He comagnetometer for our 129Xe EDM measurements, we have decided to incorporate a double-cell geometry which enables us to suppress a frequency shift due to contact interaction with polarized Rb atoms. In this study, the production and relaxation of 3He spin polarization in the double cell were studied. As a result, the followings were achieved: a polarization of 1.04(8)%, a longitudinal spin relaxation time of 10.1(5) h, and a transverse relaxation time of 2,340 s. With these improvements, concurrent operation of the 129Xe and 3He masers has been realized, and EDM measurement will be started in near future using a cell designed based on the results of this study.

  6. The Neutron and 3He Spin Structure Functions at Low Q^2

    SciTech Connect

    Vincent Sulkosky

    2009-08-01

    Experiment E97-110 was performed at the Thomas Jefferson National Accelerator Facility in Hall A to provide a precise measurement of the moments of the neutron and $^{3}$He spin structure functions. A longitudinally-polarized electron beam was scattered from a longitudinally or transversely polarized $^{3}$He target. The extended Gerasimov-Drell-Hearn integral and other moments of the neutron and $^{3}$He spin structure functions were extracted at very low momentum transfers (0.02 $< Q^{2} <$ 0.3 [GeV$/c$]$^{2}$). These data allow us to make a benchmark check of Chiral Perturbation Theory calculations in a region where they are expected to be valid. In these proceedings, the experimental details are discussed and preliminary results on the moments of the spin structure functions are presented.

  7. Comparative study of nuclear effects in polarized electron scattering from 3 He

    DOE PAGESBeta

    Ethier, J. J.; Melnitchouk, W.

    2013-11-01

    We present a detailed analysis of nuclear effects in inclusive electron scattering from polarized 3He nuclei for polarization asymmetries, structure functions and their moments, both in the nucleon resonance and deep-inelastic regions. We compare the results of calculations within the weak binding approximation at finite Q2 with the effective polarization ansatz often used in experimental data analyses, and explore the impact of Δ components in the nuclear wave function and nucleon off-shell corrections on extractions of the free neutron structure. Using the same framework we also make predictions for the Q2 dependence of quasielastic scattering from polarized 3He, data onmore » which can be used to constrain the spin-dependent nuclear smearing functions in 3He.« less

  8. Excitation function of (3)He-particle induced nuclear reactions on natural palladium.

    PubMed

    Al-Abyad, M; Tárkányi, F; Ditrói, F; Takács, S

    2014-12-01

    Excitation functions of (3)He-particle induced nuclear reactions on natural palladium were measured using the standard stacked foil technique and high resolution γ-ray spectroscopy. From their threshold energies up to 27MeV, cross-sections for (nat)Pd((3)He,x)(103,104,105,106m,110m,111,112)Ag and (nat)Pd((3)He,x)(104,105,107,111m)Cd reactions were measured. The nuclear model codes TALYS-1.4, and EMPIRE-3.1 were used to describe the formation of these products. The present data were compared to theoretical results and to the available experimental data. Integral yields for some important radioisotopes were determined. PMID:25218461

  9. Asymmetries in electron-induced breakup of polarized {sup 3}He

    SciTech Connect

    Sirca, Simon

    2011-10-01

    The Jefferson Lab Experiment E05-102 "Measurement of A{sub x}' and A{sub z}' asymmetries in the quasi-elastic {sup 3}He(e,e'd) reaction" was performed in Hall A in 2009. The main physics motivation of the experiment was to investigate the effects of small components of the {sup 3}He ground-state wave-function by a simultaneous measurement of double-polarization asymmetries in quasi-elastic kinematics for three exclusive channels, (e,e'd), (e,e'p), and (e,e'n), at almost identical momentum transfers, as well as for (e,e'). This experiment will help map the spin structure of the {sup 3}He nucleus onto the picture of the "free" polarized neutron. As such, it is of great relevance to the polarized-neutron programs at Jefferson Lab and beyond.

  10. Diffusive transfer of polarized 3He gas through depolarizing magnetic gradients

    NASA Astrophysics Data System (ADS)

    Maxwell, J. D.; Epstein, C. S.; Milner, R. G.

    2015-03-01

    Transfer of polarized 3He gas across spatially varying magnetic fields will facilitate a new source of polarized 3He ions for particle accelerators. In this context, depolarization of atoms as they pass through regions of significant transverse field gradients is a major concern. To understand these depolarization effects, we have built a system consisting of a Helmholtz coil pair and a solenoid, both with central magnetic fields of order 30 gauss. The atoms are polarized via metastability exchange optical pumping in the Helmholtz coil and are in diffusive contact via a glass tube with a second test cell in the solenoid. We have carried out measurements of the spin relaxation during transfer of polarization in 3He at 1 torr by diffusion. We explore the use of measurements of the loss of polarization taken in one cell to infer the polarization in the other cell.

  11. Realistic Calculation of the {sup 3}He + p (hep ) Astrophysical Factor

    SciTech Connect

    Marcucci, L. E.; Schiavilla, R.; Viviani, M.; Kievsky, A.; Rosati, S.

    2000-06-26

    The astrophysical factor for the proton weak capture on {sup 3}He is calculated with correlated hyperspherical harmonic wave functions corresponding to a realistic Hamiltonian consisting of the Argonne v{sub 18} two-nucleon and Urbana-IX three-nucleon interactions. The nuclear weak current has vector and axial-vector components with one- and many-body terms. All possible transitions connecting any of the p {sup 3} He S - and P -wave channels to {sup 4}He are considered. The S factor at a p {sup 3} He center-of-mass energy of 10 keV is predicted to be 10.1x10{sup -20} keV b , a factor of {approx_equal}4.5 larger than the value adopted in the standard solar model. The P -wave transitions are found to contribute about 40% of the calculated S factor. (c) 2000 The American Physical Society.

  12. Observation of the 3He(n, tp) Reaction by Detection of Far-Ultraviolet Radiation

    PubMed Central

    Thompson, Alan K.; Coplan, Michael A.; Cooper, John W.; Hughes, Patrick P.; Vest, Robert E.; Clark, Charles

    2008-01-01

    We have detected Lyman alpha radiation, 121.6 nm light produced from the n = 2 to n = 1 transition in atomic hydrogen, as a product of the 3He(n, tp) nuclear reaction occurring in a cell of 3He gas. The predominant source of this radiation appears to be decay of the 2p state of tritium produced by charge transfer and excitation collisions with the background 3He gas. Under the experimental conditions reported here we find yields of tens of Lyman alpha photons for every neutron reaction. These results suggest a method of cold neutron detection that is complementary to existing technologies that use proportional counters. In particular, this approach may provide single neutron sensitivity with wide dynamic range capability, and a class of neutron detectors that are compact and operate at relatively low voltages. PMID:27096112

  13. Longitudinal assessment of treatment effects on pulmonary ventilation using 1H/3He MRI multivariate templates

    NASA Astrophysics Data System (ADS)

    Tustison, Nicholas J.; Contrella, Benjamin; Altes, Talissa A.; Avants, Brian B.; de Lange, Eduard E.; Mugler, John P.

    2013-03-01

    The utitlity of pulmonary functional imaging techniques, such as hyperpolarized 3He MRI, has encouraged their inclusion in research studies for longitudinal assessment of disease progression and the study of treatment effects. We present methodology for performing voxelwise statistical analysis of ventilation maps derived from hyper­ polarized 3He MRI which incorporates multivariate template construction using simultaneous acquisition of IH and 3He images. Additional processing steps include intensity normalization, bias correction, 4-D longitudinal segmentation, and generation of expected ventilation maps prior to voxelwise regression analysis. Analysis is demonstrated on a cohort of eight individuals with diagnosed cystic fibrosis (CF) undergoing treatment imaged five times every two weeks with a prescribed treatment schedule.

  14. Bi-layer ^3He: a simple two dimensional heavy fermion system with quantum criticality

    NASA Astrophysics Data System (ADS)

    Saunders, John

    2008-03-01

    Two dimensional helium films provide simple model systems for the investigation of quantum phase transitions in two dimensions. Monolayer ^3He absorbed on graphite, with various pre-platings, behaves as a two dimensional Mott-Hubbard system, complete with a density driven ``metal-insulator'' transition [1, 2] into what appears to be a gapless spin-liquid. In two dimensions the corrections to the temperature dependence of the fluid heat capacity, beyond the term linear in T, are anomalous and attributed to quasi-1D scattering [3]. On the other hand, bi-layer ^3He films adsorbed on the surface of graphite show evidence of two-band heavy-fermion behavior and quantum criticality [4, 5]. The relevant control parameter is the total density of the ^3He film. The ^3He bilayer system can be driven toward a quantum critical point (QCP) at which the effective mass appears to diverge, the effective inter-band hybridization vanishes, and a local moment state appears. A theoretical model in terms of a ``Kondo breakdown selective Mott transition'' has recently been suggested [6]. * In collaboration with: A Casey, M Neumann, J Nyeki, B Cowan. [1] Evidence for a Mott-Hubbard Transition in a Two-Dimensional ^3He Fluid Monolayer, A. Casey, H. Patel, J. Ny'eki, B. P. Cowan, and J. Saunders Phys. Rev. Lett. 90, 115301 (2003) [2] D Tsuji et al. J. Low Temp. Phys. 134, 31 (2004) [3] A V Chubukov et al. Phys. Rev. B71, 205112 (2005) [4] Bilayer ^3He; a simple two dimensional heavy fermion system with quantum criticality, Michael Neumann, Jan Nyeki, Brian Cowan, John Saunders. Science 317, 1356 (2007) [5] Heavy fermions in the original Fermi liquid. Christopher A Hooley and Andrew P Mackenzie. Science 317, 1332 (2007) [6] C Pepin, Phys. Rev. Lett. 98, 206401 (2007) and A Benlagra and C Pepin, arXiv: 0709.0354

  15. Characterizing a sewage plume using the 3H-3He dating technique

    USGS Publications Warehouse

    Shapiro, Stephanie Dunkle; LeBlanc, Denis; Schlosser, Peter; Ludin, Andrea

    1999-01-01

    An extensive 3H-3He study was performed to determine detailed characteristics of a regional flow system and a sewage plume over a distance of 4 km in a sand and gravel aquifer at Otis Air Base in Falmouth, Massachusetts. 3H-3He ages increase with depth in individual piezometer clusters and with distance along flowpaths. However, the age gradient with depth (Δt/Δz) is smaller in the plume than that in the regional waters, due to the intense recharge in the infiltration beds. The 1960s bomb peak of tritium in precipitation is archived longitudinally along a flowline through the main axis of the plume and vertically in individual piezometer clusters. On the eastern side of the sampling area, where water from Ashumet Pond forces plume water deeper into the flow system, 3H-3He ages are young at depth because the 3H-3He "clock" is reset due to outgassing of helium in the pond. A reconstruction of the tritium input functions for the regional and plume samples shows that there is no offset in the peak [3H]+[3Hetrit] concentrations for the plume and regional water, indicating that the water from supply wells for use on the base is young. The 3H-3He ages and detergent concentrations in individual wells are consistent with the beginning of use of detergents and the time period when their concentrations in sewage would have been greatest. Ages and hydraulic properties calculated using the 3H-3He data compare well with those from previous investigations and from particle-tracking simulations.

  16. Boron-coated straws as a replacement for 3He-based neutron detectors

    NASA Astrophysics Data System (ADS)

    Lacy, Jeffrey L.; Athanasiades, Athanasios; Sun, Liang; Martin, Christopher S.; Lyons, Tom D.; Foss, Michael A.; Haygood, Hal B.

    2011-10-01

    US and international government efforts to equip major seaports with large area neutron detectors, aimed to intercept the smuggling of nuclear materials, have precipitated a critical shortage of 3He gas. It is estimated that the annual demand of 3He for US security applications alone is more than the worldwide supply. This is strongly limiting the prospects of neutron science, safeguards, and other applications that rely heavily on 3He-based detectors. Clearly, alternate neutron detection technologies that can support large sensitive areas, and have low gamma sensitivity and low cost must be developed. We propose a low-cost technology based on long copper tubes (straws), coated on the inside with a thin layer of 10B-enriched boron carbide ( 10B 4C). In addition to the high abundance of boron on Earth and low cost of 10B enrichment, the boron-coated straw (BCS) detector offers distinct advantages over conventional 3He-based detectors, and alternate technologies such as 10BF 3 tubes and 10B-coated rigid tubes. These include better distribution inside moderator assemblies, many-times faster electronic signals, no pressurization, improved gamma-ray rejection, no toxic or flammable gases, and ease of serviceability. We present the performance of BCS detectors dispersed in a solid plastic moderator to address the need for portal monitoring. The design adopts the outer dimensions of currently deployed 3He-based monitors, but takes advantage of the small BCS diameter to achieve a more uniform distribution of neutron converter throughout the moderating material. We show that approximately 63 BCS detectors, each 205 cm long, distributed inside the moderator, can match or exceed the detection efficiency of typical monitors fitted with a 5 cm diameter 3He tube, 187 cm long, pressurized to 3 atm.

  17. Development of high-performance alkali-hybrid polarized 3He targets for electron scattering

    NASA Astrophysics Data System (ADS)

    Singh, Jaideep T.; Dolph, P. A. M.; Tobias, W. A.; Averett, T. D.; Kelleher, A.; Mooney, K. E.; Nelyubin, V. V.; Wang, Yunxiao; Zheng, Yuan; Cates, G. D.

    2015-05-01

    Background: Polarized 3He targets have been used as effective polarized neutron targets for electron scattering experiments for over twenty years. Over the last ten years, the effective luminosity of polarized 3He targets based on spin-exchange optical pumping has increased by over an order of magnitude. This has come about because of improvements in commercially-available lasers and an improved understanding of the physics behind the polarization process. Purpose: We present the development of high-performance polarized 3He targets for use in electron scattering experiments. Improvements in the performance of polarized 3He targets, target properties, and operating parameters are documented. Methods: We utilize the technique of alkali-hybrid spin-exchange optical pumping to polarize the 3He targets. Spectrally narrowed diode lasers used for the optical pumping greatly improved the performance. A simulation of the alkali-hybrid spin-exchange optical pumping process was developed to provide guidance in the design of the targets. Data was collected during the characterization of 24 separate glass target cells, each of which was constructed while preparing for one of four experiments at Jefferson Laboratory in Newport News, Virginia. Results: From the data obtained we made determinations of the so-called X -factors that quantify a temperature-dependent and as-yet poorly understood spin-relaxation mechanism that limits the maximum achievable 3He polarization to well under 100%. The presence of the X -factor spin-relaxation mechanism was clearly evident in our data. Good agreement between the simulation and the actual target performance was obtained by including details such as off-resonant optical pumping. Included in our results is a measurement of the K -3He spin-exchange rate coefficient kseK=(7.46 ±0.62 ) ×10-20cm3/s over the temperature range 503 K to 563 K. Conclusions: In order to achieve high performance under the operating conditions described in this paper

  18. SEOP polarized 3He Neutron Spin Filters for the JCNS user program

    NASA Astrophysics Data System (ADS)

    Babcock, Earl; Salhi, Zahir; Theisselmann, Tobias; Starostin, Denis; Schmeissner, Johann; Feoktystov, Artem; Mattauch, Stefan; Pistel, Patrick; Radulescu, Aurel; Ioffe, Alexander

    2016-04-01

    Over the past several years the JCNS has been developing in-house applications for neutron polarization analysis (PA). These methods include PA for separation of incoherent from coherent scattering in soft matter studies (SANS), and online polarization for analysis for neutron reflectometry, SANS, GISANS and eventually spectroscopy. This paper will present an overview of the user activities at the JCNS at the MLZ and gives an overview of the polarization 3He methods and devices used. Additionally we will summarise current projects which will further support the user activities using polarised 3He spin filters.

  19. B phase with polar distortion in superfluid {sup 3}He in “ordered” aerogel

    SciTech Connect

    Dmitriev, V. V. Senin, A. A.; Soldatov, A. A.; Surovtsev, E. V.; Yudin, A. N.

    2014-12-15

    The properties of the low-temperature superfluid phase of {sup 3}He in “nematically ordered” aerogel in which strands are almost parallel to one another are investigated by nuclear magnetic resonance methods. Such a strong anisotropy of the aerogel affects the phase diagram of {sup 3}He and the structure of superfluid phases. A theoretical model of the B phase with polar distortion is developed. It is shown that this model successfully describes the observed properties of the low-temperature phase.

  20. Resonance transition 795-nm Rubidium laser using 3He buffer gas

    SciTech Connect

    Wu, S S; Soules, T F; Page, R H; Mitchell, S C; Kanz, V K; Beach, R J

    2007-08-02

    We report the first demonstration of a 795-nm Rubidium resonance transition laser using a buffer gas consisting of pure {sup 3}He. This follows our recent demonstration of a hydrocarbon-free 795-nm Rubidium resonance laser which used naturally-occurring He as the buffer gas. Using He gas that is isotopically enriched with {sup 3}He yields enhanced mixing of the Rb fine-structure levels. This enables efficient lasing at reduced He buffer gas pressure, improving thermal management in high average power Rb lasers and enhancing the power scaling potential of such systems.

  1. High-sensitivity measurement of 3He-4He isotopic ratios for ultracold neutron experiments

    NASA Astrophysics Data System (ADS)

    Mumm, H. P.; Huber, M. G.; Bauder, W.; Abrams, N.; Deibel, C. M.; Huffer, C. R.; Huffman, P. R.; Schelhammer, K. W.; Janssens, R.; Jiang, C. L.; Scott, R. H.; Pardo, R. C.; Rehm, K. E.; Vondrasek, R.; Swank, C. M.; O'Shaughnessy, C. M.; Paul, M.; Yang, L.

    2016-06-01

    Research efforts ranging from studies of solid helium to searches for a neutron electric dipole moment require isotopically purified helium with a ratio of 3He to 4He at levels below that which can be measured using traditional mass spectroscopy techniques. We demonstrate an approach to such a measurement using accelerator mass spectroscopy, reaching the 10-14 level of sensitivity, several orders of magnitude more sensitive than other techniques. Measurements of 3He/4He in samples relevant to the measurement of the neutron lifetime indicate the need for substantial corrections. We also argue that there is a clear path forward to sensitivity increases of at least another order of magnitude.

  2. A validation of the 3H/3He method for determining groundwater recharge

    NASA Astrophysics Data System (ADS)

    Solomon, D. K.; Schiff, S. L.; Poreda, R. J.; Clarke, W. B.

    1993-09-01

    Tritium and He isotopes have been measured at a site where groundwater flow is nearly vertical for a travel time of 100 years and where recharge rates are spatially variable. Because the mid-1960s 3H peak (arising from aboveground testing of thermonuclear devices) is well-defined, the vertical groundwater velocity is known with unusual accuracy at this site. Utilizing 3H and its stable daughter 3He to determine groundwater ages, we compute a recharge rate of 0.16 m/yr, which agrees to within about 5% of the value based on the depth of the 3H peak (measured both in 1986 and 1991) and two-dimensional modeling in an area of high recharge. Zero 3H/3He age occurs at a depth that is approximately equal to the average depth of the annual low water table, even though the capillary fringe extends to land surface during most of the year at the study site. In an area of low recharge (0.05 m/yr) where the 3H peak (and hence the vertical velocity) is also well-defined, the 3H/3He results could not be used to compute recharge because samples were not collected sufficiently far above the 3H peak; however, modeling indicates that the 3H/3He age gradient near the water table is an accurate measure of vertical velocities in the low-recharge area. Because 3H and 3He have different diffusion coefficients, and because the amount of mechanical mixing is different in the area of high recharge than in the low-recharge area, we have separated the dispersive effects of mechanical mixing from molecular diffusion. We estimate a longitudinal dispersivity of 0.07 m and effective diffusion coefficients for 3H (3HHO) and 3He of 2.4×10-5 and 1.3×10-4 m2/day, respectively. Although the 3H/3He age gradient is an excellent indicator of vertical groundwater velocities above the mid-1960s 3H peak, dispersive mixing and diffusive loss of 3He perturb the age gradient near and below the 3H peak.

  3. Polarisation and compression of {sup 3}He for Magnetic Resonance Imaging purposes

    SciTech Connect

    Geurts, D. G.; Brand, J. F. J. van den; Bulten, H. J.; Poolman, H. R.; Ferro-Luzzi, M.; Nicolay, K.

    1998-01-20

    Magnetic Resonance Imaging is often used in medical science as a diagnostic tool for the human body. Conventional MRI uses the NMR signal from the protons of water molecules in tissue to image the interior of the patient's body. However, for certain areas such as the lungs and airways, the usage of a highly polarised gas yields better results. We are currently constructing an apparatus that uses polarised {sup 3}He gas to produce detailed images of those signal-deficient moyeties. We also plan to study possible uptake of polarised {sup 3}He gas by the circulatory system to image other organs.

  4. Two-body pion absorption on {sup 3}He at threshold

    SciTech Connect

    Lee, T.S.H.; Kiang, L.L.; Riska, D.O.

    1995-08-01

    We showed that a drastic reduction of the ratio of the rates of the reactions {sup 3}He({pi}{sup -},nn) and {sup 3}He({pi}{sup -},np) for stopped pions is obtained once the effect of the short-range two-nucleon components of the axial charge operator for nuclear systems is taken into account. In a calculation using realistic models of nucleon-nucleon interactions in the construction of these short-range components of the axial charge operator, the predicted ratios can be brought to within 10-20% of the empirical value. A paper describing our results was published.

  5. Degassing of 3H/ 3He, CFCs and SF 6 by denitrification: Measurements and two-phase transport simulations

    NASA Astrophysics Data System (ADS)

    Visser, Ate; Schaap, Joris D.; Broers, Hans Peter; Bierkens, Marc F. P.

    2009-01-01

    The production of N 2 gas by denitrification may lead to the appearance of a gas phase below the water table prohibiting the conservative transport of tracer gases required for groundwater dating. We used a two-phase flow and transport model (STOMP) to study the reliability of 3H/ 3He, CFCs and SF 6 as groundwater age tracers under agricultural land where denitrification causes degassing. We were able to reproduce the amount of degassing ( R2 = 69%), as well as the 3H ( R2 = 79%) and 3He* ( R2 = 76%) concentrations observed in a 3H/ 3He data set using simple 2D models. We found that the TDG correction of the 3H/ 3He age overestimated the control 3He/ 3He age by 2.1 years, due to the accumulation of 3He* in the gas phase. The total uncertainty of degassed 3H/ 3He ages of 6 years (± 2 σ) is due to the correction of degassed 3He* using the TDG method, but also due to the travel time in the unsaturated zone and the diffusion of bomb peak 3He*. CFCs appear to be subject to significant degradation in anoxic groundwater and SF 6 is highly susceptible to degassing. We conclude that 3H/ 3He is the most reliable method to date degassed groundwater and that two-phase flow models such as STOMP are useful tools to assist in the interpretation of degassed groundwater age tracer data.

  6. The Gas Motion Due To Non-Uniform Heating By 3He(n,p)3H Reactions In The Nuclear-Pumped3He -Lasers

    NASA Astrophysics Data System (ADS)

    Çetin, Füsun

    2007-04-01

    In the nuclear pumped-lasers, the passage of these energetic charged particles through gas results in a non-uniform volumetric energy deposition. This spatial non-uniformity induces a gas motion, which results in density and hence refractive index gradients that affects the laser's optical behaviour. The motion of 3He gas in a closed cavity is studied when it experiences transient and spatially non-uniform volumetric heating caused by the passage of 3He(n,p)3H reaction products. Gas motion is described by the radial velocity field of gas flow. Spatial and temporal variations of radial gas velocity are calculated for various tube parameters by using a dynamic energy deposition model. In the calculations, it is assumed that the laser tube is irradiated with neutrons from the pulse at a peak power of 1200 MW corresponding to a maximum thermal neutron flux of 8×1016 n / cm2sn in the central channel of ITU TRIGA Mark II Reactor. Results are examined.

  7. The Gas Motion Due To Non-Uniform Heating By 3He(n,p)3H Reactions In The Nuclear-Pumped3He -Lasers

    SciTech Connect

    Cetin, Fuesun

    2007-04-23

    In the nuclear pumped-lasers, the passage of these energetic charged particles through gas results in a non-uniform volumetric energy deposition. This spatial non-uniformity induces a gas motion, which results in density and hence refractive index gradients that affects the laser's optical behaviour. The motion of 3He gas in a closed cavity is studied when it experiences transient and spatially non-uniform volumetric heating caused by the passage of 3He(n,p)3H reaction products. Gas motion is described by the radial velocity field of gas flow. Spatial and temporal variations of radial gas velocity are calculated for various tube parameters by using a dynamic energy deposition model. In the calculations, it is assumed that the laser tube is irradiated with neutrons from the pulse at a peak power of 1200 MW corresponding to a maximum thermal neutron flux of 8x1016 n / cm2sn in the central channel of ITU TRIGA Mark II Reactor. Results are examined.

  8. Exposure chamber

    DOEpatents

    Moss, Owen R.; Briant, James K.

    1983-01-01

    An exposure chamber includes an imperforate casing having a fluid inlet at the top and an outlet at the bottom. A single vertical series of imperforate trays is provided. Each tray is spaced on all sides from the chamber walls. Baffles adjacent some of the trays restrict and direct the flow to give partial flow back and forth across the chambers and downward flow past the lowermost pan adjacent a central plane of the chamber.

  9. Neutron dosimetry at commercial nuclear plants. Final report of Subtask C: /sup 3/He neutron spectrometer

    SciTech Connect

    Brackenbush, L.W.; Reece, W.D.; Tanner, J.E.

    1984-09-01

    In commercial nuclear power plants, personnel routinely enter containment for maintenance and inspections while the reactor is operating and can be exposed to intense neutron fields. The low-energy neutron fields found in reactor containment cause problems in proper interpretation of TLD-albedo dosimeters and survey instrument readings. This report describes a technique that can aid plant health physicists to improve the accuracy of personnel neutron dosimetry programs. A /sup 3/He neutron spectrometer can be used to measure neutron energy spectra and determine dose equivalent rates at work locations inside containment. Energy correction factors for TLD-albedo dosimeters can be determined from the measured spectra if the dosimeter energy response is known, or from direct measurements with dosimeters placed on phantoms at locations where the dose equivalent rate has been measured. This report describes how to assemble a spectrometer system using only commercially available components, how to use it for reactor energy spectrum measurements, and how to analyze the data and interpret the results. Both /sup 3/He and multisphere spectrometers were used to measure neutron energy spectra and dose equivalent at three PWRs and one BWR. In general, the /sup 3/He spectrometer measures higher dose equivalent rates than the multisphere spectrometer. In the energy range from 10 keV to 1 MeV, the dose equivalents measured by the /sup 3/He spectrometer and multisphere spectrometer agree within about 35% for the spectra measured.

  10. Electron screening in the {sup 3}He(d,p){sup 4}He reaction

    SciTech Connect

    Barker, F. C.

    2007-02-15

    A reanalysis of data for the {sup 3}He(d,p){sup 4}He reaction obtained using the Trojan-horse method, together with data from a direct measurement, leads to an electron-screening potential that is not consistent with the adiabatic limit, but it is consistent with a previous value from different data.

  11. Zeeman relaxation of cold atomic iron and nickel in collisions with {sup 3}He

    SciTech Connect

    Johnson, Cort; Newman, Bonna; Kleppner, Daniel; Greytak, Thomas J.; Brahms, Nathan; Doyle, John M.

    2010-06-15

    We have measured the ratio {gamma} of the diffusion cross section to the angular momentum reorientation cross section in the colliding Fe-{sup 3}He and Ni-{sup 3}He systems. Nickel (Ni) and iron (Fe) atoms are introduced via laser ablation into a cryogenically cooled experimental cell containing cold (<1 K) {sup 3}He buffer gas. Elastic collisions rapidly cool the translational temperature of the ablated atoms to the {sup 3}He temperature. {gamma} is extracted by measuring the decays of the atomic Zeeman sublevels. For our experimental conditions, thermal energy is comparable to the Zeeman splitting. As a result, thermal excitations between Zeeman sublevels significantly impact the observed decay. To determine {gamma} accurately, we introduce a model of Zeeman-state dynamics that includes thermal excitations. We find {gamma}{sub Ni-}{sup 3}{sub He}=5x10{sup 3} and {gamma}{sub Fe-}{sup 3}{sub He{<=}}3x10{sup 3} at 0.75 K in a 0.8-T magnetic field. These measurements are interpreted in the context of submerged shell suppression of spin relaxation, as studied previously in transition metals and rare-earth-metal atoms [C. I. Hancox, S. C. Doret, M. T. Hummon, R. V. Krems, and J. M. Doyle, Phys. Rev. Lett. 94, 013201 (2005); C. I. Hancox, S. C. Doret, M. T. Hummon, L. Luo, and J. M. Doyle, Nature (London) 431, 281 (2004); A. Buchachenko, G. Chaasiski, and M. Szczniak, Eur. Phys. J. D 45, 147 (2007)].

  12. 3D MRI of non-Gaussian 3He gas diffusion in the rat lung

    NASA Astrophysics Data System (ADS)

    Jacob, Richard E.; Laicher, Gernot; Minard, Kevin R.

    2007-10-01

    In 3He magnetic resonance images of pulmonary air spaces, the confining architecture of the parenchymal tissue results in a non-Gaussian distribution of signal phase that non-exponentially attenuates image intensity as diffusion weighting is increased. Here, two approaches previously used for the analysis of non-Gaussian effects in the lung are compared and related using diffusion-weighted 3He MR images of mechanically ventilated rats. One approach is model-based and was presented by Yablonskiy et al., while the other approach utilizes the second order decay contribution that is predicted from the cumulant expansion theorem. Total lung coverage is achieved using a hybrid 3D pulse sequence that combines conventional phase encoding with sparse radial sampling for efficient gas usage. This enables the acquisition of nine 3D images using a total of only ˜1 L of hyperpolarized 3He gas. Diffusion weighting ranges from 0 s/cm 2 to 40 s/cm 2. Results show that the non-Gaussian effects of 3He gas diffusion in healthy rat lungs are directly attributed to the anisotropic geometry of lung microstructure as predicted by the Yablonskiy model, and that quantitative analysis over the entire lung can be reliably repeated in time-course studies of the same animal.

  13. Direct Observation of a Majorana Quasiparticle Heat Capacity in 3He

    NASA Astrophysics Data System (ADS)

    Bunkov, Y. M.

    2014-04-01

    The Majorana fermion, which acts as its own antiparticle, was suggested by Majorana in 1937 (Nuovo Cimento 14:171). While no stable particle with Majorana properties has yet been observed, Majorana quasiparticles (QP) may exist at the boundaries of topological insulators. Here we report the preliminary results of direct observation of Majorana QPs by a precise measurements of superfluid 3He heat capacity. The bulk superfluid 3He heat capacity falls exponentially with cooling at the temperatures significantly below the energy gap. Owing to the zero energy gap mode the Majorana heat capacity falls in a power law. The Majorana heat capacity can be larger than bulk one at some temperature, which depends on surface to volume ratio of the experimental cell. Some times ago we developed the Dark matter particles detector (DMD) on a basis of superfluid 3He which is working at the frontier of extremely low temperatures (Winkelmann et al., Nucl. Instrum. Meth. A 559:384-386, 2006). Here we report the observation of zero gap mode of Majorana, follows from the new analyses of DMD heat capacity, published early. We have found a 10 % deviation from the bulk superfluid 3He heat capacity at the temperature of 135 μK. This deviation corresponds well to the theoretical value for Majorana heat capacity at such low temperature. (Note, there were no fitting parameters).

  14. A New Method for Precision Cold Neutron Polarimetry Using a 3He Spin Filter

    PubMed Central

    Wietfeldt, F. E.; Gentile, T. R.

    2005-01-01

    We present a new method for precision measurement of the capture flux polarization of a polychromatic (white), continuous cold neutron beam, polarized by a 3He spin filter. This method allows an in situ measurement and does not require knowledge of the neutron beam wavelength distribution. We show that a polarimetry precision of 0.1 % is possible.

  15. Deep mixing of 3He: reconciling Big Bang and stellar nucleosynthesis.

    PubMed

    Eggleton, Peter P; Dearborn, David S P; Lattanzio, John C

    2006-12-01

    Low-mass stars, approximately 1 to 2 solar masses, near the Main Sequence are efficient at producing the helium isotope 3He, which they mix into the convective envelope on the giant branch and should distribute into the Galaxy by way of envelope loss. This process is so efficient that it is difficult to reconcile the low observed cosmic abundance of 3He with the predictions of both stellar and Big Bang nucleosynthesis. Here we find, by modeling a red giant with a fully three-dimensional hydrodynamic code and a full nucleosynthetic network, that mixing arises in the supposedly stable and radiative zone between the hydrogen-burning shell and the base of the convective envelope. This mixing is due to Rayleigh-Taylor instability within a zone just above the hydrogen-burning shell, where a nuclear reaction lowers the mean molecular weight slightly. Thus, we are able to remove the threat that 3He production in low-mass stars poses to the Big Bang nucleosynthesis of 3He. PMID:17068226

  16. Precision measurement of the neutron magnetic form factor from {sup 3}He(e, e')

    SciTech Connect

    Dipangkar Dutta

    2000-12-12

    A precision measurement of the inclusive quasielastic transverse asymmetry A{sub T'} from {sup 3}He(e, e') was completed recently at Hall A at Jefferson Lab (E95-001). The preliminary results on the neutron magnetic form factor at low Q{sup 2} are presented here.

  17. In situ polarized 3He system for the Magnetism Reflectometer at the Spallation Neutron Source.

    PubMed

    Tong, X; Jiang, C Y; Lauter, V; Ambaye, H; Brown, D; Crow, L; Gentile, T R; Goyette, R; Lee, W T; Parizzi, A; Robertson, J L

    2012-07-01

    We report on the in situ polarized (3)He neutron polarization analyzer developed for the time-of-flight Magnetism Reflectometer at the Spallation Neutron Source at Oak Ridge National Laboratory. Using the spin exchange optical pumping method, we achieved a (3)He polarization of 76% ± 1% and maintained it for the entire three-day duration of the test experiment. Based on transmission measurements with unpolarized neutrons, we show that the average analyzing efficiency of the (3)He system is 98% for the neutron wavelength band of 2-5 Å. Using a highly polarized incident neutron beam produced by a supermirror bender polarizer, we obtained a flipping ratio of >100 with a transmission of 25% for polarized neutrons, averaged over the wavelength band of 2-5 Å. After the cell was depolarized for transmission measurements, it was reproducibly polarized and this performance was maintained for three weeks. A high quality polarization analysis experiment was performed on a reference sample of Fe/Cr multilayer with strong spin-flip off-specular scattering. Using a combination of the position sensitive detector, time-of-flight method, and the excellent parameters of the (3)He cell, the polarization analysis of the two-dimensional maps of reflected, refracted, and off-specular scattered intensity above and below the horizon were obtained, simultaneously. PMID:22852718

  18. Association of 3He-rich solar energetic particles with large-scale coronal waves

    NASA Astrophysics Data System (ADS)

    Bucik, Radoslav; Innes, Davina; Guo, Lijia; Mason, Glenn M.; Wiedenbeck, Mark

    2016-07-01

    Impulsive or 3He-rich solar energetic particle (SEP) events have been typically associated with jets or small EUV brightenings. We identify 30 impulsive SEP events from ACE at L1 during the solar minimum period 2007-2010 and examine their solar sources with high resolution STEREO-A EUV images. At beginning of 2007, STEREO-A was near the Earth while at the end of the investigated period, when there were more events, STEREO-A was leading the Earth by 90°. Thus STEREO-A provided a better (more direct) view on 3He-rich flares generally located on the western Sun's hemisphere. Surprisingly, we find that about half of the events are associated with large-scale EUV coronal waves. This finding provides new insights on acceleration and transport of 3He-rich SEPs in solar corona. It is believed that elemental and isotopic fractionation in impulsive SEP events is caused by more localized processes operating in the flare sites. The EUV waves have been reported in gradual SEP events in association with fast coronal mass ejections. To examine their role on 3He-rich SEPs production the energy spectra and relative abundances are discussed. R. Bucik is supported by the Deutsche Forschungsgemeinschaft under grant BU 3115/2-1.

  19. Single-collision approximation for p{sup 3}-He elastic scattering at low energy

    SciTech Connect

    Abusini, M.

    2009-06-15

    A theoretical approach to studying four-body reactions of p{sup 3}-He elastic scattering that takes consistently into account the single-collision mechanism is reported. The theoretical results obtained by this method were compared with experimental data, and the agreement is found to be quite satisfactory.

  20. Torsion Pendulum Experiments with Superfluid 3He in ``Nematically Ordered'' Aerogel

    NASA Astrophysics Data System (ADS)

    Zhelev, Nikolay; Smith, Eric; Sebastian, Abhilash; Parpia, Jeevak

    2014-03-01

    A new type of highly anisotropic alumina aerogel is used to induce directional disorder in superfluid 3He. The aerogel sample consists of a network of long strands that have a preferred orientation (nematic order). It is placed in the head of a double torsion pendulum with the anisotropy axis oriented along the axis of the pendulum. We observe the frequency shift of the symmetric torsion mode of the pendulum in order to determine the superfluid fraction of the embedded 3He. The superfluid transition temperature of the fluid in the aerogel is measured to be very close to that of bulk 3He. However, in contrast to the bulk phase diagram, the region of stability of the Equal Spin Pairing (ESP) superfluid phase is enhanced on cooling. In addition, unlike the case of 3He in isotropic silica aerogel, the ESP phase reappears on warming. We compare our measurements to the NMR data reported in and discuss the possible structure of the observed superfluid phases.

  1. Surface Majorana fermions and bulk collective modes in superfluid 3He-B

    NASA Astrophysics Data System (ADS)

    Park, YeJe; Chung, Suk Bum; Maciejko, Joseph

    2015-02-01

    The theoretical study of topological superfluids and superconductors has so far been carried out largely as a translation of the theory of noninteracting topological insulators into the superfluid language, whereby one replaces electrons by Bogoliubov quasiparticles and single-particle band Hamiltonians by Bogoliubov-de Gennes Hamiltonians. Band insulators and superfluids are, however, fundamentally different: While the former exist in the absence of interparticle interactions, the latter are broken symmetry states that owe their very existence to such interactions. In particular, unlike the static energy gap of a band insulator, the gap in a superfluid is due to a dynamical order parameter that is subject to both thermal and quantum fluctuations. In this work, we explore the consequences of bulk quantum fluctuations of the order parameter in the B phase of superfluid 3He on the topologically protected Majorana surface states. Neglecting the high-energy amplitude modes, we find that one of the three spin-orbit Goldstone modes in 3He-B couples to the surface Majorana fermions. This coupling in turn induces an effective short-range two-body interaction between the Majorana fermions, with coupling constant inversely proportional to the strength of the nuclear dipole-dipole interaction in bulk 3He. A mean-field theory suggests that the surface Majorana fermions in 3He-B may be in the vicinity of a metastable gapped time-reversal-symmetry-breaking phase.

  2. The overview and early measurements from the n 3He experiment

    NASA Astrophysics Data System (ADS)

    Garishvili, Garishvili; n3 HE Collaboration

    2015-04-01

    The main goal of the n 3He experiment at the Spallation Neutron Source (SNS) at ORNL is to perform a precise measurement of the parity violating (PV) weak amplitude of the reaction n->+3 He --> T + p + 765 KeV. In particular, the goal is to measure the spatial asymmetry of emitted protons with respect to the neutron spin direction. This asymmetry is expected to be very small (<10-7) since the NN interaction is dominated by the parity conserving (PC) strong amplitude. The final goal is to measure the asymmetry in the n 3He experiment with an accuracy of ~ 2 ×10-8 to isolate the I=0 components of the hadronic weak interaction, which is vital for constraining weak coupling constants predicted by theory. The n 3He detector was installed and commissioned in December 2014 on the Fundamental Neutron Physics Beamline at the SNS. Production data taking is expected to start by the end of January 2015 and planned to run until the end of 2015. The status of the experiment will be presented, including early data.

  3. Phase-space analysis of convection in a /sup 3/He - superfluid /sup 4/He solution

    SciTech Connect

    Haucke, H.; Maeno, Y.

    1982-01-01

    Observations have been made on thermal convection below 1K in a dilute solution of /sup 3/He in superfluid /sup 4/He contained in a cylindrical cell of aspect ratio GAMMA = 1.20. Complicated oscillatory phenomena were observed with a high degree of reproducibility using two temperature sensors. Phase-space analysis suggests a description in terms of strange-attractor dynamics.

  4. Packed Powder as Superleak for Spin Pump Experiments in Superfluid 3He A1

    NASA Astrophysics Data System (ADS)

    Kamada, N.; Yamaguchi, A.; Motoyama, G.; Sumiyama, A.; Aoki, Y.; Okuda, Y.; Kojima, H.

    2014-04-01

    Experimental exploration of highly spin-polarized states of liquid 3He by applying external magnetic field is limited by the availability of static magnetic field. In the "ferromagnetic" superfluid A1 phase of liquid 3He there is an alternate method for boosting spin-polarization by the process of spin pumping without requiring such high magnetic field. The spin pumping in the A1 phase takes advantage of a superleak (SL) acting simultaneously as a filter for both entropy and spin. The spin pump technique that uses the SL-spin filter and a mechanical actuator enables us to directly boost polarization of 3He. The amount of enhancement of spin polarization has been limited so far. We are now developing a new type of SL filter made of packed aluminum oxide powder (referred as PAP-SL), in order to achieve greater enhancement of spin polarization. Several kinds of the PAP-SL filter were constructed by pressing aluminum oxide powders into a cylinder holder. The packed structures were carefully characterized by a flow-rate-measurement, X-ray tomography, and mercury intrusion porosimetry. The preliminary result shows that the PAP-SL works as SL filter for the superfluid 3He.

  5. Regional Ventilation Changes in Severe Asthma after Bronchial Thermoplasty with 3He MR Imaging and CT

    PubMed Central

    Thomen, Robert P.; Sheshadri, Ajay; Quirk, James D.; Kozlowski, Jim; Ellison, Henry D.; Szczesniak, Rhonda D.; Castro, Mario

    2015-01-01

    Purpose To quantify regional lung ventilation in healthy volunteers and patients with severe asthma (both before and after thermoplasty) by using a combination of helium 3 (3He) magnetic resonance (MR) imaging and computed tomography (CT), with the intention of developing more effective image-guided treatments for obstructive lung diseases. Materials and Methods With approval of the local institutional review board, informed consent, and an Investigational New Drug Exemption, six healthy volunteers and 10 patients with severe asthma were imaged in compliance with HIPAA regulations by using both multidetector CT and 3He MR imaging. Individual bronchopulmonary segments were labeled voxel by voxel from the CT images and then registered to the 3He MR images by using custom software. The 3He signal intensity was then analyzed by evaluating the volume-weighted fraction of total-lung signal intensity present in each segment (segmental ventilation percentage [SVPsegmental ventilation percentage]) and by identifying the whole-lung defect percentage and the segmental defect percentage. Of the 10 patients with asthma, seven received treatment with bronchial thermoplasty and were imaged with 3He MR a second time. Changes in segmental defect percentages and whole-lung defect percentages are presented. Results Ventilation measures for healthy volunteers yielded smaller segment-to-segment variation (mean SVPsegmental ventilation percentage, 100% ± 18 [standard deviation]) than did the measures for patients with severe asthma (mean SVPsegmental ventilation percentage, 97% ± 23). Patients with asthma also demonstrated larger segmental defect percentages (median, 13.5%; interquartile range, 8.9%–17.8%) than healthy volunteers (median, 6%; interquartile range, 5.6%–6.3%). These quantitative results confirm what is visually observed on the 3He images. A Spearman correlation of r = −0.82 was found between the change in whole-lung defect percentage and the number of days between

  6. Set-up of a high-resolution 300 mK atomic force microscope in an ultra-high vacuum compatible 3He/10 T cryostat

    NASA Astrophysics Data System (ADS)

    von Allwörden, H.; Ruschmeier, K.; Köhler, A.; Eelbo, T.; Schwarz, A.; Wiesendanger, R.

    2016-07-01

    The design of an atomic force microscope with an all-fiber interferometric detection scheme capable of atomic resolution at about 500 mK is presented. The microscope body is connected to a small pumped 3He reservoir with a base temperature of about 300 mK. The bakeable insert with the cooling stage can be moved from its measurement position inside the bore of a superconducting 10 T magnet into an ultra-high vacuum chamber, where the tip and sample can be exchanged in situ. Moreover, single atoms or molecules can be evaporated onto a cold substrate located inside the microscope. Two side chambers are equipped with standard surface preparation and surface analysis tools. The performance of the microscope at low temperatures is demonstrated by resolving single Co atoms on Mn/W(110) and by showing atomic resolution on NaCl(001).

  7. Set-up of a high-resolution 300 mK atomic force microscope in an ultra-high vacuum compatible (3)He/10 T cryostat.

    PubMed

    von Allwörden, H; Ruschmeier, K; Köhler, A; Eelbo, T; Schwarz, A; Wiesendanger, R

    2016-07-01

    The design of an atomic force microscope with an all-fiber interferometric detection scheme capable of atomic resolution at about 500 mK is presented. The microscope body is connected to a small pumped (3)He reservoir with a base temperature of about 300 mK. The bakeable insert with the cooling stage can be moved from its measurement position inside the bore of a superconducting 10 T magnet into an ultra-high vacuum chamber, where the tip and sample can be exchanged in situ. Moreover, single atoms or molecules can be evaporated onto a cold substrate located inside the microscope. Two side chambers are equipped with standard surface preparation and surface analysis tools. The performance of the microscope at low temperatures is demonstrated by resolving single Co atoms on Mn/W(110) and by showing atomic resolution on NaCl(001). PMID:27475560

  8. Electric breakdown and ionization detection in normal liquid and superfluid 4He for the SNA nEDM experiment

    NASA Astrophysics Data System (ADS)

    Karcz, Maciej

    A new experiment to search for the neutron electric dipole moment (nEDM) is under construction at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. The SNS nEDM experiment is a national collaboration spanning over 20 universities and laboratories with more than 100 physicists and engineers contributing to the research and development. The search for a nEDM is a precision test of time reversal symmetry in particle physics, in the absence of a discovery, the SNS nEDM experiment seeks to improve the present limit on the nEDM value by two orders of magnitude. A non-zero value of the nEDM would help to explain the asym- metry between matter and anti-matter in the universe by providing an additional source of charge conjugation and parity symmetry violation, a necessary ingredient in the theory of baryogenesis in the early universe. The nEDM experiment will measure the Larmor precession frequency of neutrons by detecting scintillation from neutron capture by a dilute concentration of 3He inside a bath of superfluid 4He. Neutron capture by 3He is spin-dependent and the magnetic moments of the neutron and the 3He nucleus are comparable. A direct measurement of the precession frequency of polarized 3He and scintillation from neutron capture allows for the relative precession frequencies of 3He and the neutron to be determined. The experiment will then look for changes in the relative precession of 3He and neutrons under the influence of strong electric fields. 3He has negligible EDM and therefore any deviation due to an applied electric field would be from a nEDM. The nEDM experiment will need to apply strong electric fields inside superfluid (SF) 4He and it was necessary to investigate the ability of SF 4He to sustain electric fields. An experiment to study electric breakdown in superfluid 4He was constructed at the Indiana University Center for Exploration of Energy and Matter (CEEM). The experiment studied the electric breakdown behavior of liquid

  9. 3HE RECOVERY FROM A TRITIUM-AGED LANA75 SAMPLE

    SciTech Connect

    Shanahan, K.

    2010-12-01

    {sup 3}He recovery is a topic of recent interest. One potential recovery source is from metal hydride materials once used to store tritium, as the decay product, {sup 3}He, is primarily trapped in the metal lattice, usually in bubbles, with such materials. In 2001, a Tritium Exposure Program (TEP) sample known as LANA75-SP1 was retired and the material was removed from the test cell and stored. Subsequently scoping temperature programmed desorption (TPD) experiments were conducted on that material to see what it might take to drive out He and residual H isotopes (the heel). Two experiments consisted of heating the sample in the presence of an excess of tin (the so-called Sn fusion experiment), and one was a simple TPD with no additives. Prior data on the so-called '21-month bed' material in the 1980's had produced {approx}21 cc of gas per gram of a LANA30 material (LaNi4.7Al0.3), with approximately 67% of that being {sup 3}He and the rest being D{sub 2} (Fig.3). However, the material had to be heated in excess of 850 C to obtain that level. Heating to less produced approximately half that amount of gas. The data also showed that {sup 3}He was released at different temperatures than the residual hydrogen isotopes. Unfortunately this implies full {sup 3}He recovery will be a difficult process. Therefore, it seemed advisable to attempt to extract as much information from the 3 scoping experiments from 2001-2 as possible.

  10. 3H/3He age data in assessing the susceptibility of wells to contamination

    USGS Publications Warehouse

    Manning, A.H.; Solomon, D.K.; Thiros, S.A.

    2005-01-01

    Regulatory agencies are becoming increasingly interested in using young-ground water dating techniques, such as the 3H/3He method, in assessing the susceptibility of public supply wells (PSWs) to contamination. However, recent studies emphasize that ground water samples of mixed age may be the norm, particularly from long-screened PSWs, and tracer-based "apparent" ages can differ substantially from actual mean ages for mixed-age samples. We present age and contaminant data from PSWs in Salt Lake Valley, Utah, that demonstrate the utility of 3H and 3He measurements in evaluating well susceptibility, despite potential age mixing. Initial 3H concentrations (measured 3H + measured tritiogenic 3He) are compared to those expected based on the apparent 3H/3He age and the local precipitation 3H record. This comparison is used to determine the amount of modern water (recharged after ???1950) vs. prebomb water (recharged before ???1950) samples might contain. Concentrations of common contaminants were also measured using detection limits generally lower than those used for regulatory purposes. A clear correlation exists between the potential magnitude of the modern water fraction and both the occurrence and concentration of contaminants. For samples containing dominantly modern water based on their initial 3H concentrations, potential discrepancies between apparent 3H/ 3He ages and mean ages are explored using synthetic samples that are random mixtures of different modern waters. Apparent ages can exceed mean ages by up to 13 years for these samples, with an exponential age distribution resulting in the greatest discrepancies.

  11. Solar Sources of 3He-rich Solar Energetic Particle Events in Solar Cycle 24

    NASA Astrophysics Data System (ADS)

    Nitta, Nariaki V.; Mason, Glenn M.; Wang, Linghua; Cohen, Christina; Wiedenbeck, Mark E.

    2015-04-01

    We still do not understand the origin of impulsive SEP events enriched in 3He and heavy ions. A major impediment may be the difficulty to observe them in the corona, apart from the common knowledge that 3He-rich SEP events are correlated with longer-than-metric type III radio bursts and <100 keV electron events. This is because their X-ray and EUV signatures tend to be tiny and short-lived. Using high-cadence and high-sensitivity EUV images obtained by SDO/AIA, we investigate the solar sources of 26 3He-rich SEP events during solar cycle 24 that were well-observed by ACE. The source locations are further confirmed in data from STEREO/EUVI, which capture solar activities in the regions inaccessible from the Earth. We confirm that 3He-rich events have a broad longitudinal distribution (including locations well behind the west limb) and that a frequent association with coronal jets and narrow CMEs. Some events were seen in association with eruptions of closed structures and large-scale coronal propagating fronts (LCPFs, aka EUV waves). While these LCPFs may account for the occasional mismatching polarities at the source region and L1 in such a way that the particles are transported to and released at a region that has the opposite polarity, their associated CMEs may not be fast enough to drive shock waves for particle acceleration. Moreover, open field lines from PFSS models may not be correct for the entire Sun although they often look reasonable in discrete locations. We also discuss the apparent lack of correlation between the solar sources and the basic properties of 3He-rich SEP events.

  12. Precision neutron interferometric measurement of the n- 3He coherent neutron scattering length

    NASA Astrophysics Data System (ADS)

    Huffman, P. R.; Jacobson, D. L.; Schoen, K.; Arif, M.; Black, T. C.; Snow, W. M.; Werner, S. A.

    2004-07-01

    A measurement of the n- 3He coherent scattering length using neutron interferometry is reported. The result, bc =(5.8572±0.0072) fm , improves the measured precision of any single measurement of bc by a factor of eight; the previous world average, bc =(5.74±0.04) fm , now becomes bc =(5.853±0.007) fm . Measurements of the n-p , n-d , and n- 3He coherent scattering lengths have now been performed using the same technique, thus allowing one to extract the scattering length ratios: parameters that minimize systematic errors. We obtain values of bn 3He / bnp =(-1.5668±0.0021) and bnd / bnp =(-1.7828±0.0014) . Using the new world average value of bc and recent high-precision spin-dependent scattering length data also determined by neutron optical techniques, we extract new values for the bound singlet and triple scattering lengths of b0 =(9.949±0.027) fm and b1 =(4.488±0.017) fm for the n- 3He system. The free nuclear singlet and triplet scattering lengths are a0 =(7.456±0.020) fm and a1 =(3.363±0.013) fm . The coherent scattering cross section is σc =(4.305±0.007) b and the total scattering cross section is σs =(5.837±0.014) b . Comparisons of a0 and a1 to the only existing high-precision theoretical predictions for the n- 3He system, calculated using a resonating group technique with nucleon-nucleon potentials incorporating three-nucleon forces, have been performed. Neutron scattering length measurements in few-body systems are now sensitive enough to probe small effects not yet adequately treated in present theoretical models.

  13. SU-E-T-96: Demonstration of a Consistent Method for Correcting Surface Dose Measurements Using Both Solid State and Ionization Chamber Detectors

    SciTech Connect

    Reynolds, T; Gerbi, B; Higgins, P

    2014-06-01

    Purpose: To compare the surface dose (SD) measured using a PTW 30-360 extrapolation chamber with different commonly used dosimeters (Ds): parallel plate ion chambers (ICs): RMI-449 (Attix), Capintec PS-033, PTW 30-329 (Markus) and Memorial; TLD chips (cTLD), TLD powder (pTLD), optically stimulated (OSLs), radiochromic (EXR2) and radiographic (EDR2) films, and to provide an intercomparison correction to Ds for each of them. Methods: Investigations were performed for a 6 MV x-ray beam (Varian Clinac 2300, 10x10 cm{sup 2} open field, SSD = 100 cm). The Ds were placed at the surface of the solid water phantom and at the reference depth dref=1.7cm. The measurements for cTLD, OSLs, EDR2 and EXR2 were corrected to SD using an extrapolation method (EM) indexed to the baseline PTW 30-360 measurements. A consistent use of the EM involved: 1) irradiation of three Ds stacked on top of each other on the surface of the phantom; 2) measurement of the relative dose value for each layer; and, 3) extrapolation of these values to zero thickness. An additional measurement was performed with externally exposed OSLs (eOSLs), that were rotated out of their protective housing. Results: All single Ds measurements overestimated the SD compared with the extrapolation chamber, except for Attix IC. The closest match to the true SD was measured with the Attix IC (− 0.1%), followed by pTLD (0.5%), Capintec (4.5%), Memorial (7.3%), Markus (10%), cTLD (11.8%), eOSL (12.8%), EXR2 (14%), EDR2 (14.8%) and OSL (26%). The EM method of correction for SD worked well for all Ds, except the unexposed OSLs. Conclusion: This EM cross calibration of solid state detectors with an extrapolation or Attix chamber can provide thickness corrections for cTLD, eOSLs, EXR2, and EDR2. Standard packaged OSLs were not found to be simply corrected.

  14. SU-E-P-35: Real-Time Patient Transit Dose Verification of Volumetric Modulated Arc Radiotherapy by a 2D Ionization Chamber Array

    SciTech Connect

    Liu, X

    2015-06-15

    Purpose: To explore the real-time dose verification method in volumetric modulated arc radiotherapy (VMAT) with a 2D array ion chamber array. Methods: The 2D ion chamber array was fixed on the panel of electronic portal imaging device (EPID). Source-detector distance (SDD)was 140cm. 8mm RW3 solid water was added to the detector panel to achieve maximum readings.The patient plans for esophageal, prostate and liver cancers were selected to deliver on the cylindrical Cheese phantom 5 times in order to validate the reproducibility of doses. Real-time patient transit dose measurements were performed at each fraction. Dose distributions wereevaluated using gamma index criteria of 3mm DTA and 3% dose difference referred to the firsttime Result. Results: The gamma index pass rate in the Cheese phantom were about 98%; The gamma index pass rate for esophageal, liver and prostate cancer patient were about 92%,94%, and 92%, respectively; Gamma pass rate for all single fraction were more than 90%. Conclusion: The 2D array is capable of monitoring the real time transit doses during VMAT delivery. It is helpful to improve the treatment accuracy.

  15. Application of FIGAERO (Filter Inlet for Gases and AEROsol) coupled to a high resolution time of flight chemical ionization mass spectrometer to field and chamber organic aerosol: Implications for carboxylic acid formation and gas-particle partitioning from monoterpene oxidation

    NASA Astrophysics Data System (ADS)

    Lopez-Hilfiker, F.; Mohr, C.; Ehn, M.; Rubach, F.; Mentel, T. F.; Kleist, E.; Wildt, J.; Thornton, J. A.

    2013-12-01

    We present measurements of a large suite of gas and particle phase carboxylic acid containing compounds made with a Filter Inlet for Gas and AEROsol (FIGAERO) coupled to a high resolution time of flight chemical ionization mass spectrometer (HR-ToF-CIMS) developed at the University of Washington. A prototype operated with acetate negative ion proton transfer chemistry was deployed on the Julich Plant Atmosphere Chamber to study a-pinene oxidation, and a modified version was deployed at the SMEAR II forest station in Hyytiälä, Finland and SOAS, in Brent Alabama. We focus here on results from JPAC and Hyytiälä, where we utilized the same ionization method most selective towards carboxylic acids. In all locations, 100's of organic acid compounds were observed in the gas and particles and many of the same composition acids detected in the gas-phase were detected in the particles upon temperature programmed thermal desorption. Particulate organics detected by FIGAERO are highly correlated with organic aerosol mass measured by an AMS, providing additional volatility and molecular level information about collected aerosol. The fraction of a given compound measured in the particle phase follows expected trends with elemental composition, but many compounds would not be well described by an absorptive partitioning model assuming unity activity coefficients. Moreover the detailed structure in the thermal desorption signals reveals a contribution from thermal decomposition of large molecular weight organics and or oligomers with implications for partitioning measurements and model validation

  16. JET (3He)-D scenarios relying on RF heating: survey of selected recent experiments

    NASA Astrophysics Data System (ADS)

    Van Eester, D.; Lerche, E.; Andrew, Y.; Biewer, T. M.; Casati, A.; Crombé, K.; de la Luna, E.; Ericsson, G.; Felton, R.; Giacomelli, L.; Giroud, C.; Hawkes, N.; Hellesen, C.; Hjalmarsson, A.; Joffrin, E.; Källne, J.; Kiptily, V.; Lomas, P.; Mantica, P.; Marinoni, A.; Mayoral, M.-L.; Ongena, J.; Puiatti, M.-E.; Santala, M.; Sharapov, S.; Valisa, M.; JET EFDA contributors

    2009-04-01

    Recent JET experiments have been devoted to the study of (3He)-D plasmas involving radio frequency (RF) heating. This paper starts by discussing the RF heating efficiency theoretically expected in such plasmas, covering both relevant aspects of wave and of particle dynamics. Then it gives a concise summary of the main conclusions drawn from recent experiments that were either focusing on studying RF heating physics aspects or that were adopting RF heating as a tool to study plasma behavior. Depending on the minority concentration chosen, different physical phenomena are observed. At very low concentration (X[3He] < 1%), energetic tails are formed which trigger MHD activity and result in loss of fast particles. Alfvén cascades were observed and gamma ray tomography indirectly shows the impact of sawtooth crashes on the fast particle orbits. Low concentration (X[3He] < 10%) favors minority heating while for X[3He] Gt 10% electron mode conversion damping becomes dominant. Evidence for the Fuchs et al standing wave effect (Fuchs et al 1995 Phys. Plasmas 2 1637-47) on the absorption is presented. RF induced deuterium tails were observed in mode conversion experiments with large X[3He] (≈18%). As tentative modeling shows, the formation of these tails can be explained as a consequence of wave power absorption by neutral beam particles that efficiently interact with the waves well away from the cold D cyclotron resonance position as a result of their substantial Doppler shift. As both ion and electron RF power deposition profiles in (3He)-D plasmas are fairly narrow—giving rise to localized heat sources—the RF heating method is an ideal tool for performing transport studies. Various of the experiments discussed here were done in plasmas with internal transport barriers (ITBs). ITBs are identified as regions with locally reduced diffusivity, where poloidal spinning up of the plasma is observed. The present know-how on the role of RF heating for impurity transport is

  17. A validation of the [sup 3]H/[sup 3]He method for determining groundwater recharge

    SciTech Connect

    Solomon, D.K. ); Schiff, S.L. ); Poreda, R.J. ); Clarke, W.B. )

    1993-09-01

    Tritium and He isotopes have been measured at a site where groundwater flow is nearly vertical for a travel time of 100 years and where recharge rates are spatially variable. Because the mid-1960s [sup 3]H peak (arising from aboveground testing of thermonuclear devices) is well-defined, the vertical groundwater velocity is known with unusual accuracy at this site. Utilizing [sup 3]H and its stable daughter [sup 3]He to determine groundwater ages, we compute a recharge rate of 0.16 m/yr, which agrees to within about 5% of the value based on the depth of the [sup 3]H peak (measured both in 1986 and 1991) and two-dimensional modeling in an area of high recharge. Zero [sup 3]H/[sup 3]He age occurs at a depth that is approximately equal to the average depth of the annual low water table, even though the capillary fringe extends to land surface during most of the year at the study site. In an area of low recharge (0.05 m/yr) where the [sup 3]H peak (and hence the vertical velocity) is also well-defined, the [sup 3]H/[sup 3]He results could not be used to compute recharge because samples were not collected sufficiently far above the [sup 3]H peak; however, modeling indicates that the [sup 3]H/[sup 3]He age gradient near the water table is an accurate measure of vertical velocities in the low-recharge area. Because [sup 3]H and [sup 3]He have different diffusion coefficients, and because the amount of mechanical mixing is different in the area of high recharge than in the low-recharge area, we have separated the dispersive effects of mechanical mixing from molecular diffusion. We estimate a longitudinal dispersivity of 0.07 m and effective diffusion coefficients for [sup 3]H ([sup 3]HHO) and [sup 3]He of 2.4 x 10[sup [minus]5] and 1.3 x 10[sup [minus]4] m[sup 2]/day, respectively. 26 refs., 8 figs., 1 tab.

  18. Neutral-beam-injection fueling for a small, D-3He burning, field-reversed-configuration reactor

    NASA Astrophysics Data System (ADS)

    Buttolph, Michael; Stotler, Daren; Cohen, Samuel

    2013-10-01

    Rocket propulsion powered by the D-3He fusion reaction in a Field Reversed Configuration (FRC) has been proposed for a variety of solar-system missions. Two key unique features of this concept are a relatively small, 25-cm-radius, plasma core and a relatively thick (10 cm), dense (1e14 cm3), and cool (100 eV electron temperature) scrape-off layer (SOL). The SOL contains the heated propellant - likely hydrogen, deuterium or helium - and also fusion reaction products at a lower density (ca. 1e12 cm-3). A critical design question is the refueling of the fusion reactants. A moderate energy neutral-beam method is considered. It must be able to penetrate the SOL without significant losses but must be stopped in the core. DEGAS 2, a Monte-Carlo code designed to model neutral transport, was implemented to simulate beam-plasma interactions including ionization and charge exchange of the neutral beam's helium-3 and deuterium atoms by impact in the SOL and core plasma with thermal plasma constituents and fusion reaction products. Operational methods to alleviate the effects deleterious reactions such as deuterium charge-exchange in the SOL are described.

  19. Laboratory chamber experiments exploring the potential use of artificially ionized layers of gas as a Bragg reflector for over-the-horizon signals

    NASA Astrophysics Data System (ADS)

    Kuo, S. P.; Zhang, Y. S.; Lee, M. C.; Kossey, Paul; Barker, Robert J.

    1992-12-01

    A set of parallel plasma layers is generated by two intersecting microwave pulses in a chamber containing dry air at a pressure comparable to the upper atmosphere. The dependence of the breakdown conditions on the pressure and pulse length is examined. The results are shown to be consistent with the appearance of tail erosion of microwave pulse caused by air breakdown. Bragg scattering experiments, using the plasma layers as a Bragg reflector are then performed. Both time domain and frequency domain measurements of wave scattering are conducted. The experimental results are found to agree very well with the theory. Moreover, the time domain measurement of wave scattering provides an unambiguous way for determining the temporal evolution of electron density during the first 100-microsec period.

  20. Laboratory chamber experiments exploring the potential use of artificially ionized layers of gas as a Bragg reflector for over-the-horizon signals

    NASA Technical Reports Server (NTRS)

    Kuo, S. P.; Zhang, Y. S.; Lee, M. C.; Kossey, Paul; Barker, Robert J.

    1992-01-01

    A set of parallel plasma layers is generated by two intersecting microwave pulses in a chamber containing dry air at a pressure comparable to the upper atmosphere. The dependence of the breakdown conditions on the pressure and pulse length is examined. The results are shown to be consistent with the appearance of tail erosion of microwave pulse caused by air breakdown. Bragg scattering experiments, using the plasma layers as a Bragg reflector are then performed. Both time domain and frequency domain measurements of wave scattering are conducted. The experimental results are found to agree very well with the theory. Moreover, the time domain measurement of wave scattering provides an unambiguous way for determining the temporal evolution of electron density during the first 100-microsec period.

  1. Experiment E89-044 on the Quasielastic 3He(e,e'p) Reaction at Jefferson Laboratory

    SciTech Connect

    E. Penel-Nottaris

    2004-07-07

    The Jefferson Lab Hall A E89-044 experiment has measured the 3He(e,e'p) reaction cross-sections. The extraction of the longitudinal and transverse response functions for the two-body break-up 3He(e,e'p)d reaction in parallel kinematics allows the study of the bound proton electromagnetic properties inside the 3He nucleus and the involved nuclear mechanisms beyond plane wave approximations.

  2. Calibration of the RSS-131 high efficiency ionization chamber for radiation dose monitoring during plasma experiments conducted on plasma focus device

    NASA Astrophysics Data System (ADS)

    Szewczak, Kamil; Jednoróg, Sławomir

    2014-10-01

    Plasma research poses a radiation hazard. Due to the program of deuterium plasma research using the PF-1000 device, it is an intensive source of neutrons (up to 1011 n · pulse -1) with energy of 2,45 MeV and ionizing electromagnetic radiation with a broad energy spectrum. Both types of radiation are mostly emitted in ultra-short pulses (˜100 ns). The aim of this work was to test and calibrate the RSS-131 radiometer for its application in measurements of ultra-short electromagnetic radiation pulses with broad energy spectrum emitted during PF-1000 discharge. In addition, the results of raw measurements performed in the control room are presented.

  3. Development of a Spatially Resolved ^3He Quasi-Particle Detector

    NASA Astrophysics Data System (ADS)

    Barquist, C. S.; Zheng, P.; Jiang, W. G.; Lee, Y.; Yoon, Y. K.; Schumann, T.; Nogan, J.; Lilly, M.

    2016-05-01

    Andreev surface bound sates are known to exist on the boundaries of superfluid ^3He-B. However, the detailed nature of their interaction with bulk quasi-particles is not well known. In a manner similar to angle-resolved photo-emission spectroscopy, surface states can be probed by measuring the change in momentum of bulk quasi-particles scattered from the surface. In order to make such a measurement, we have designed a spatially resolved quasi-particle detector. The detector consists of an array of micro-machined resonators, which are sensitive to quasi-particle flux. The detector is based on previously developed micro-machined resonators, which have been successfully used to study superfluid ^3He-B and ^4He. Presented here is the design of the detector and the fabrication procedure.

  4. Gadolinium Thin Foils in a Plasma Panel Sensor as an Alternative to 3He

    SciTech Connect

    Varner Jr, Robert L; Beene, James R; Friedman, Dr. Peter S.

    2010-01-01

    Gadolinium has long been investigated as a detector for neutrons. It has a thermal neutron capture cross-section that is unparalleled among stable elements, because of the isotopes $^{155,157}$Gd. As a replacement for $^3$He, gadolinium has a significant defect, it produces many gamma-rays with an energy sum of 8 MeV. It also produces conversion electrons, mostly 29 keV in energy. The key to replacing $^3$He with gadolinium is using a gamma-blind electron detector to detect the conversion electrons. We suggest that coupling a layer of gadolinium to a Plasma Panel Sensor (PPS) can provide highly efficient, nearly gamma-blind detection of the conversion. The PPS is a proposed detector under development as a dense array of avalanche counters based on plasma display technology. We will present simulations of the response of prototypes of this detector and considerations of the use of gadolinium in the PPS.

  5. The First Measurement of Neutron Transversity on a Transversely Polarized 3He Target

    SciTech Connect

    Yi Qiang

    2009-12-01

    We recently measured the neutron target single spin asymmetry in the semi-inclusive deep inelastic 3He (e,e',pi+/-)X reactions with a transversely polarized 3He target. The experiment was performed in Hall A at Jefferson Lab from October 2008 to February 2009. Pions were detected in the high-resolution spectrometer in coincidence with scattered electrons detected by the BigBite spectrometer. The kinematic coverage focuses on the valence quark region, x = 0.1 - 0.4, at Q2 = 1-3 (GeV/c)2. With good particle identifications using a RICH detector and an aerogel Cherenkov counter, data on kaons were obtained at the same time. The data from this experiment, when combined with the world data, will provide constraints on the Transversity and Sivers distributions on both u-quark and d-quark in the valence quark region.

  6. Long-Range Order in the A-like Phase of Superfluid 3He in Aerogel

    NASA Astrophysics Data System (ADS)

    Fomin, I. A.

    2008-02-01

    A mutual action of the random anisotropy brought in the superfluid 3He by aerogel and of the global anisotropy caused by its deformation is considered. Strong global anisotropy tends to suppress fluctuations of orientation of the order parameter and stabilizes ABM order parameter. In a limit of vanishing anisotropy fluctuations of ABM order parameter became critical. It is argued that still in a region of small fluctuations the order parameter changes its form to be less sensitive to the random anisotropy. For a favorable landscape of the free energy of superfluid 3He the fluctuations remain small even in a limit of vanishing global anisotropy and the long-range order is maintained.

  7. Effect of temperature on performance of {sup 3}He filled neutron proportional counters

    SciTech Connect

    Desai, Shraddha S.

    2014-04-24

    Neutron detectors used for cosmic neutron monitoring and various other applications are mounted in hostile environment. It is essential for detectors to sustain extreme climatic conditions, such as extreme temperature and humidity. Effort is made to evaluate the performance of detectors in extreme temperature in terms of pulse height distribution and avalanche formation. Neutron detectors filled with {sup 3}He incorporate an additive gas with quantity optimized for a particular application. Measurements are performed on neutron detectors filled with {sup 3}He and stopping gases Kr and CF{sub 4}. Detector performance for these fill gas combinations in terms of pulse height distribution is evaluated. Gas gain and Diethorn gas constants measured and analyzed for the microscopic effect on pulse formation. Results from these investigations are presented.

  8. Dynamics of {sup 3}He impurities in {sup 4}He films

    SciTech Connect

    Clements, B.E. |; Krotscheck, E. |; Saarela, M.

    1995-08-01

    Using a microscopic variational theory the authors calculate the binding energy of {sup 3}He impurities in films of {sup 4}He absorbed to a graphite substrate. Without adjustable parameters, they obtain excellent agreement with the experimental binding energies for the ground state of the {sup 3}He impurity. To calculate excited states, they then introduce a time-dependent variational wave function. In that way, the impurity acquires a hydrodynamic effective mass for its motion parallel to the surface due to hydrodynamic backflow. Excited states have a finite lifetime. When these effects are included, both the energy of the first excited state of the impurity, and the effective mass of the ground state, also agree well with experimental data.

  9. High-3He plume origin and temporal-spatial evolution of the Siberian flood basalts

    USGS Publications Warehouse

    Basu, A.R.; Poreda, R.J.; Renne, P.R.; Teichmann, F.; Vasiliev, Y.R.; Sobolev, N.V.; Turrin, B.D.

    1995-01-01

    An olivine nephelinite from the lower part of a thick alkalic ultrabasic and mafic sequence of volcanic rocks of the northeastern part of the Siberian flood basalt province (SFBP) yielded a 40ArX39Ar plateau age of 253.3 ?? 2.6 million years, distinctly older than the main tholeiitic pulse of the SFBP at 250.0 million years. Olivine phenocrysts of this rock showed 3He/4He ratios up to 12.7 times the atmospheric ratio; these values suggest a lower mantle plume origin. The neodymium and strontium isotopes, rare earth element concentration patterns, and cerium/lead ratios of the associated rocks were also consistent with their derivation from a near-cnondritic, primitive plume. Geochemical data from the 250-million-year-old volcanic rocks higher up in the sequence indicate interaction of this high-3He SFBP plume with a suboceanic-type upper mantle beneath Siberia.

  10. Optical Pumping Spin Exchange {sup 3}He Gas Cells for Magnetic Resonance Imaging

    SciTech Connect

    Kim, W.; Stepanyan, S. S.; Kim, A.; Jung, Y.; Woo, S.; Yurov, M.; Jang, J.

    2009-08-04

    We present a device for spin-exchange optical pumping system to produce large quantities of polarized noble gases for Magnetic Resonance Imaging (MRI). A method and design of apparatus for pumping the polarization of noble gases is described. The method and apparatus enable production, storage and usage of hyperpolarized noble gases for different purposes, including Magnetic Resonance Imaging of human and animal subjects. Magnetic imaging agents breathed into lungs can be observed by the radio waves of the MRI scanner and report back physical and functional information about lung's health and desease. The technique known as spin exchange optical pumping is used. Nuclear magnetic resonance is implemented to measure the polarization of hyperpolarized gas. The cells prepared and sealed under high vacuum after handling Alkali metals into the cell and filling with the {sup 3}He-N{sub 2} mixture. The cells could be refilled. The {sup 3}He reaches around 50% polarization in 5-15 hours.

  11. Pulsed NMR in the nuclear spin ordered phases of solid 3He in a silver sinter

    NASA Astrophysics Data System (ADS)

    Millan-Chacartegui, Carmen; Schuberth, Erwin A.; Deppe, Frank; Schöttl, Stephan

    2003-05-01

    To obtain the exact spin structure of the nuclear magnetically ordered phases of solid 3He, in the BCC lattice called U2D2 and high field phase, both occurring below about 1 mK, we started a project of neutron scattering from the solid at the Hahn-Meitner Institut, Berlin. This experiment faces three main difficulties: to cool the solid to temperatures below 1 mK (or even much lower in the case of the HCP lattice), to keep it there under neutron flux, and to grow a single crystal within the sintered material needed for this purpose. As a first step we have performed pulsed NMR measurements in the ordered phases of solid 3He in a silver sinter of 700 Å particle size down to temperatures of 600 μK at various molar volumes. The samples remained in the ordered state for as long as 110 h.

  12. Apatite 4He/3He and (U-Th)/He evidence for an ancient Grand Canyon.

    PubMed

    Flowers, R M; Farley, K A

    2012-12-21

    The Grand Canyon is one of the most dramatic features on Earth, yet when and why it was carved have been controversial topics for more than 150 years. Here, we present apatite (4)He/(3)He thermochronometry data from the Grand Canyon basement that tightly constrain the near-surface cooling history associated with canyon incision. (4)He/(3)He spectra for eastern Grand Canyon apatites of differing He date, radiation damage, and U-Th zonation yield a self-consistent cooling history that substantially validates the He diffusion kinetic model applied here. Similar data for the western Grand Canyon provide evidence that it was excavated to within a few hundred meters of modern depths by ~70 million years ago (Ma), in contrast to the conventional model in which the entire canyon was carved since 5 to 6 Ma. PMID:23196906

  13. On the optimisation of the use of 3He in radiation portal monitors

    NASA Astrophysics Data System (ADS)

    Tomanin, Alice; Peerani, Paolo; Janssens-Maenhout, Greet

    2013-02-01

    Radiation Portal Monitors (RPMs) are used to detect illicit trafficking of nuclear or other radioactive material concealed in vehicles, cargo containers or people at strategic check points, such as borders, seaports and airports. Most of them include neutron detectors for the interception of potential plutonium smuggling. The most common technology used for neutron detection in RPMs is based on 3He proportional counters. The recent severe shortage of this rare and expensive gas has created a problem of capacity for manufacturers to provide enough detectors to satisfy the market demand. In this paper we analyse the design of typical commercial RPMs and try to optimise the detector parameters in order either to maximise the efficiency using the same amount of 3He or minimise the amount of gas needed to reach the same detection performance: by reducing the volume or gas pressure in an optimised design.

  14. Neutron radiography of a static density gradient of 3He gas at cryogenic temperatures

    NASA Astrophysics Data System (ADS)

    Wichmann, G.; Antognini, A.; Eggenberger, A.; Kirch, K.; Piegsa, F. M.; Soler, U.; Stahn, J.; Taqqu, D.

    2016-04-01

    We demonstrate a stationary helium gas density gradient which is needed for a proposed novel low-energy μ+ beam line. In a closed system with constant pressure the corresponding density gradient is only a function of the temperature. In a neutron radiography experiment two gas cells with different geometries were filled with 3He gas at constant pressures of about 10 mbar. Temperatures in the range from 6 K to 40 K were applied and density distributions with a maximum to minimum density ratio of larger than 3 were realized. The distribution was investigated employing the strongly neutron absorbing isotope 3He. A simple one-dimensional approach derived from Fourier's law describes the obtained gas density with a deviation < 2 %.

  15. [sup 3]He neutron detector performance in mixed neutron gamma environments

    SciTech Connect

    Johnson, N. H.; Beddingfield, D. H.

    2002-01-01

    A test program of the performance of 3He neutron proportional detectors with varying gas pressures, and their response to lligh level gamma-ray exposure in a mixed neutrodgamma environment, ha$ been performed Our intent was to identie the optimal gas pressure to reduce the gamma-ray sensitivity of these detectors. These detectors were manufxtured using materials to minimize their gamma response. Earlier work focused on 3He fill pressures of four atmospheres and above, whereas the present work focuses on a wider range of pressures. Tests have shown that reducing the .filling pressure will M e r increase the gamma-ray dose range in which the detectors can be operated.

  16. Pulsed NMR Measurements in Superfluid 3He in Aerogel of 97.5 % Porosity

    SciTech Connect

    Ishikawa, Osamu; Kado, Ryusuke; Obara, Ken; Yano, Hideo; Hata, Tohru; Nakagawa, Hisashi; Yokogawa, Hiroshi; Yokoyama, Masaru

    2006-09-07

    Aerogel is made of thin SiO2 strands of a few nanometer diameter. Since the coherence length of superfluid 3He is much longer than the silica strand diameter and is nearly the same as the mean distance between silica strands, aerogel gives us a chance to study the effects of an impurity in superfluid 3He. To investigate what superfluid states are formed in aerogel, we performed a pulsed NMR experiment. Both the A-like and B-like phases show a tipping angle dependent frequency shift in the FID signal after an rf pulse. The dependence in the A-like phase is well explained by an expectation based on the ''robust phase'' introduced by Fomin, while the FID frequencies in the B-like phase behave similarly to those observed in the bulk B phase in a slab geometry with the initial condition of a non-Leggett configuration.

  17. Compulsory Deep Mixing of 3He and CNO Isotopes on the First Giant Branch

    SciTech Connect

    Eggleton, P P; Dearborn, D P; Lattanzio, J

    2007-07-26

    We have found a deep-mixing process which occurs during First Giant Branch (FGB) evolution. It begins at the point in evolution where the surface convection zone (SCZ), having previously grown in size, starts to shrink, and it is driven by a local minimum that develops in the mean molecular weight as a result of the burning of {sup 3}He. This mixing can solve two important observational problems. One is why the interstellar medium (ISM) has not been considerably enriched in {sup 3}He since the Big Bang. The other is why products of nucleosynthesis such as {sup 13}C are progressively enriched on the upper FGB, when classical stellar modeling says that no further enrichment should take beyond the First Dredge-Up (FDU) episode, somewhat below the middle of the FGB.

  18. Surface Scattering Effect and the Stripe Order in Films of the Superfluid3He B Phase

    NASA Astrophysics Data System (ADS)

    Aoyama, Kazushi

    2016-09-01

    Surface scattering effects in thin films of the superfluid 3He B phase have been theoretically investigated, with an emphasis on the stability of the stripe order with spontaneous broken translational symmetry in the film plane and quasiparticle excitations in this spatially inhomogeneous phase. Based on the Ginzburg-Landau theory in the weak coupling limit, we have shown that the stripe order, which was originally discussed for a film with two specular surfaces, can be stable in a film with one specular and one diffusive surfaces which should correspond to superfluid 3He on a substrate. It is also found by numerically solving the Eilenberger equation that due to the stripe structure, a midgap state distinct from the surface Andreev bound state emerges and its signature is reflected in the local density of states.

  19. Probing Bogoliubov Quasiparticles in Superfluid ^3He with a `Vibrating-Wire Like' MEMS Device

    NASA Astrophysics Data System (ADS)

    Defoort, M.; Dufresnes, S.; Ahlstrom, S. L.; Bradley, D. I.; Haley, R. P.; Guénault, A. M.; Guise, E. A.; Pickett, G. R.; Poole, M.; Woods, A. J.; Tsepelin, V.; Fisher, S. N.; Godfrin, H.; Collin, E.

    2016-05-01

    We have measured the interaction between superfluid ^3He-B and a micro-machined goalpost-shaped device at temperatures below 0.2 T_c. The measured damping follows well the theory developed for vibrating wires, in which the Andreev reflection of quasiparticles in the flow field around the moving structure leads to a nonlinear frictional force. At low velocities, the damping force is proportional to velocity, while it tends to saturate for larger excitations. Above a velocity of 2.6 mm s^{-1}, the damping abruptly increases, which is interpreted in terms of Cooper-pair breaking. Interestingly, this critical velocity is significantly lower than that reported with other mechanical probes immersed in superfluid ^3He. Furthermore, we report on a nonlinear resonance shape for large motion amplitudes that we interpret as an inertial effect due to quasiparticle friction, but other mechanisms could possibly be invoked as well.

  20. Apatite 4He/3He and (U-Th)/He Evidence for an Ancient Grand Canyon

    NASA Astrophysics Data System (ADS)

    Flowers, R. M.; Farley, K. A.

    2012-12-01

    The Grand Canyon is one of the most dramatic features on Earth, yet when and why it was carved have been controversial topics for more than 150 years. Here, we present apatite 4He/3He thermochronometry data from the Grand Canyon basement that tightly constrain the near-surface cooling history associated with canyon incision. 4He/3He spectra for eastern Grand Canyon apatites of differing He date, radiation damage, and U-Th zonation yield a self-consistent cooling history that substantially validates the He diffusion kinetic model applied here. Similar data for the western Grand Canyon provide evidence that it was excavated to within a few hundred meters of modern depths by ~70 million years ago (Ma), in contrast to the conventional model in which the entire canyon was carved since 5 to 6 Ma.

  1. Magnon Condensation into a Q Ball in {sup 3}He-B

    SciTech Connect

    Bunkov, Yu. M.; Volovik, G. E.

    2007-06-29

    The theoretical prediction of Q balls in relativistic quantum fields is realized here experimentally in superfluid {sup 3}He-B. The condensed-matter analogs of relativistic Q balls are responsible for an extremely long-lived signal of magnetic induction observed in NMR at the lowest temperatures. This Q ball is another representative of a state with phase coherent precession of nuclear spins in {sup 3}He-B, similar to the well-known homogeneously precessing domain, which we interpret as Bose-Einstein condensation of spin waves--magnons. At large charge Q, the effect of self-localization is observed. In the language of relativistic quantum fields it is caused by interaction between the charged and neutral fields, where the neutral field provides the potential for the charged one. In the process of self-localization the charged field modifies locally the neutral field so that the potential well is formed in which the charge Q is condensed.

  2. Thermal Transport by Ballistic Quasiparticles in Superfluid 3He-B in the Low Temperature Limit

    SciTech Connect

    Bradley, D. I.; Fisher, S. N.; Guenault, A. M.; Haley, R. P.; Martin, H.; Pickett, G. R.; Roberts, J. E.; Tsepelin, V.

    2006-09-07

    In the temperature range below 0.2Tc, the gas of thermal excitations from the superfluid 3He-B ground state is in the ultra-dilute ballistic regime. Here we discuss preliminary measurements of the transport properties of this quasiparticle gas in a cell of cylindrical geometry with dimensions much smaller than any mean free path. The vertical cylinder, constructed from epoxy-coated paper, has vibrating wire resonator (VWR) heaters and thermometers at the top and bottom, and a small aperture at the top which provides the only exit for quasiparticles. Using the thermometer VWRs, we measure the difference in quasiparticle density between the top and bottom of the tube when we excite the top or bottom VWR heater. This gives information about the transport of energy along the cylindrical 3He sample and hence about the scattering behaviour involved when a quasiparticle impinges on the cylinder wall.

  3. Theory of (3He,(alpha)) surrogate reactions for deformed uranium nuclei

    SciTech Connect

    Thompson, I; Escher, J E

    2006-11-08

    We present the one-step theory of neutron-pickup transfer reactions with {sup 3}He projectiles on {sup 235}U and {sup 238}U. We find all the neutron eigenstates in a deformed potential, and use those in a given energy range for ({sup 3}He, {alpha}) DWBA pickup calculations to find the spin and parity distributions of the residual target nuclei. A simple smoothing convolution is used to take into account the spreading width of the single-neutron hole states into the more complicated compound nuclear states. We assume that the initial target is an even-even rotor, but can take into account spectator neutrons outside such a rotor by recombining their spin and parity at the end of the calculations.

  4. Double spin asymmetries of inclusive hadron electroproduction from a transversely polarized 3He target

    NASA Astrophysics Data System (ADS)

    Zhao, Y. X.; Allada, K.; Aniol, K.; Annand, J. R. M.; Averett, T.; Benmokhtar, F.; Bertozzi, W.; Bradshaw, P. C.; Bosted, P.; Camsonne, A.; Canan, M.; Cates, G. D.; Chen, C.; Chen, J.-P.; Chen, W.; Chirapatpimol, K.; Chudakov, E.; Cisbani, E.; Cornejo, J. C.; Cusanno, F.; Dalton, M.; Deconinck, W.; de Jager, C. W.; De Leo, R.; Deng, X.; Deur, A.; Ding, H.; Dolph, P. A. M.; Dutta, C.; Dutta, D.; El Fassi, L.; Frullani, S.; Gao, H.; Garibaldi, F.; Gaskell, D.; Gilad, S.; Gilman, R.; Glamazdin, O.; Golge, S.; Guo, L.; Hamilton, D.; Hansen, O.; Higinbotham, D. W.; Holmstrom, T.; Huang, J.; Huang, M.; Ibrahim, H. F.; Iodice, M.; Jiang, X.; Jin, G.; Jones, M. K.; Katich, J.; Kelleher, A.; Kim, W.; Kolarkar, A.; Korsch, W.; LeRose, J. J.; Li, X.; Li, Y.; Lindgren, R.; Liyanage, N.; Long, E.; Lu, H.-J.; Margaziotis, D. J.; Markowitz, P.; Marrone, S.; McNulty, D.; Meziani, Z.-E.; Michaels, R.; Moffit, B.; Muñoz Camacho, C.; Nanda, S.; Narayan, A.; Nelyubin, V.; Norum, B.; Oh, Y.; Osipenko, M.; Parno, D.; Peng, J.-C.; Phillips, S. K.; Posik, M.; Puckett, A. J. R.; Qian, X.; Qiang, Y.; Rakhman, A.; Ransome, R.; Riordan, S.; Saha, A.; Sawatzky, B.; Schulte, E.; Shahinyan, A.; Shabestari, M. H.; Širca, S.; Stepanyan, S.; Subedi, R.; Sulkosky, V.; Tang, L.-G.; Tobias, W. A.; Urciuoli, G. M.; Vilardi, I.; Wang, K.; Wojtsekhowski, B.; Wang, Y.; Yan, X.; Yao, H.; Ye, Y.; Ye, Z.; Yuan, L.; Zhan, X.; Zhang, Y.; Zhang, Y.-W.; Zhao, B.; Zheng, X.; Zhu, L.; Zhu, X.; Zong, X.; Jefferson Lab Hall A Collaboration

    2015-07-01

    We report the measurement of beam-target double spin asymmetries (ALT) in the inclusive production of identified hadrons, e ⃗ + 3He↑→h+X, using a longitudinally polarized 5.9-GeV electron beam and a transversely polarized 3He target. Hadrons (π ±,K±, and proton) were detected at 16° with an average momentum =2.35 GeV/c and a transverse momentum (pT) coverage from 0.60 to 0.68 GeV/c. Asymmetries from the 3He target were observed to be nonzero for π± production when the target was polarized transversely in the horizontal plane. The π+ and π- asymmetries have opposite signs, analogous to the behavior of ALT in semi-inclusive deep-inelastic scattering.

  5. Summary of Apollo; A D- sup 3 He tokamak reactor design

    SciTech Connect

    Kulcinski, G.L.; Blanchard, T.P.; El-Guebaly, L.A.; Emert, G.A.; Khater, H.Y.; Maynard, C.W.; Mogahed, E.A.; Santarius, J.F.; Sawan, M.E.; Sviatoslavsky, I.N.; Wittenberg, L.J. . Fusion Technology Inst.)

    1992-07-01

    In this paper, the key features of Apollo, a conceptual D-{sup 3}He tokamak reactor for commercial electricity production, are summarized. The 1000-MW (electric) design utilizes direct conversion of transport, neutron, and bremsstrahlung radiation power. The direct conversion method uses reactants, and the thermal conversion cycle uses an organic coolant. Apollo operates in the first-stability regime, with a major radius of 7.89 m, a peak magnetic field on the toroidal field coils of 19.3 T, a 53-MA plasma current, and a 6.7% beta value. The low neutron production of the D-{sup 3}He fuel cycle greatly reduces the radiation damage rate and allows a full-lifetime first wall and structure made of standard steels with only slight modifications to reduce activation levels.

  6. Spin echo small angle neutron scattering using a continuously pumped {sup 3}He neutron polarisation analyser

    SciTech Connect

    Parnell, S. R.; Li, K.; Yan, H.; Stonaha, P.; Li, F.; Wang, T.; Baxter, D. V.; Snow, W. M.; Washington, A. L.; Walsh, A.; Chen, W. C.; Parnell, A. J.; Fairclough, J. P. A.; Pynn, R.

    2015-02-15

    We present a new instrument for spin echo small angle neutron scattering (SESANS) developed at the Low Energy Neutron Source at Indiana University. A description of the various instrument components is given along with the performance of these components. At the heart of the instrument are a series of resistive coils to encode the neutron trajectory into the neutron polarisation. These are shown to work well over a broad range of neutron wavelengths. Neutron polarisation analysis is accomplished using a continuously operating neutron spin filter polarised by Rb spin-exchange optical pumping of {sup 3}He. We describe the performance of the analyser along with a study of the {sup 3}He polarisation stability and its implications for SESANS measurements. Scattering from silica Stöber particles is investigated and agrees with samples run on similar instruments.

  7. Magnon condensation into a Q ball in 3He-B.

    PubMed

    Bunkov, Yu M; Volovik, G E

    2007-06-29

    The theoretical prediction of Q balls in relativistic quantum fields is realized here experimentally in superfluid 3He-B. The condensed-matter analogs of relativistic Q balls are responsible for an extremely long-lived signal of magnetic induction observed in NMR at the lowest temperatures. This Q ball is another representative of a state with phase coherent precession of nuclear spins in 3He-B, similar to the well-known homogeneously precessing domain, which we interpret as Bose-Einstein condensation of spin waves--magnons. At large charge Q, the effect of self-localization is observed. In the language of relativistic quantum fields it is caused by interaction between the charged and neutral fields, where the neutral field provides the potential for the charged one. In the process of self-localization the charged field modifies locally the neutral field so that the potential well is formed in which the charge Q is condensed. PMID:17678101

  8. A Light-Front Approach to the 3He Spectral Function

    NASA Astrophysics Data System (ADS)

    Scopetta, Sergio; Del Dotto, Alessio; Kaptari, Leonid; Pace, Emanuele; Rinaldi, Matteo; Salmè, Giovanni

    2015-09-01

    The analysis of semi-inclusive deep inelastic electron scattering off polarized 3He at finite momentum transfers, aimed at the extraction of the quark transverse-momentum distributions in the neutron, requires the use of a distorted spin-dependent spectral function for 3He, which takes care of the final state interaction effects. This quantity is introduced in the non-relativistic case, and its generalization in a Poincaré covariant framework, in plane wave impulse approximation for the moment being, is outlined. Studying the light-front spin-dependent spectral function for a J = 1/2 system, such as the nucleon, it is found that, within the light-front dynamics with a fixed number of constituents and in the valence approximation, only three of the six leading twist T-even transverse-momentum distributions are independent.

  9. Search for the K-pp bound state via the in-flight 3He(K-, n) reaction

    NASA Astrophysics Data System (ADS)

    Sada, Y.; Ajimura, S.; Beer, G.; Bhang, H.; Bragadireanu, M.; Buehler, P.; Busso, L.; Cargnelli, M.; Choi, S.; Curceanu, C.; Enomoto, S.; Faso, D.; Fujioka, H.; Fujiwara, Y.; Fukuda, T.; Guaraldo, C.; Hashimoto, T.; Hayano, R. S.; Hiraiwa, T.; Iio, M.; Iliescu, M.; Inoue, K.; Ishiguro, Y.; Ishikawa, T.; Ishimoto, S.; Ishiwatari, T.; Itahashi, K.; Iwai, M.; Iwasaki, M.; Kato, Y.; Kawasaki, S.; Kienle, P.; Kou, H.; Ma, Y.; Marton, J.; Matsuda, Y.; Mizoi, Y.; Morra, O.; Nagae, T.; Noumi, H.; Ohnishi, H.; Okada, S.; Outa, H.; Piscicchia, K.; Poli Lener, M.; Romero Vidal, A.; Sakaguchi, A.; Sakuma, F.; Sato, M.; Scordo, A.; Sekimoto, M.; Shi, H.; Sirghi, D.; Sirghi, F.; Suzuki, K.; Suzuki, S.; Suzuki, T.; Tanida, K.; Tatsuno, H.; Tokuda, M.; Tomono, D.; Toyoda, A.; Tsukada, K.; Vazquez Doce, O.; Widmann, E.; Weunschek, B. K.; Yamaga, T.; Yamazaki, T.; Yim, H.; Zhang, Q.; Zmeskal, J.

    2014-11-01

    In the J-PARC E15 experiment, a K- pp search was performed via the 3He(K-, n) reaction at 1.0 GeV/c. A forward-going neutron is detected by a neutron counter with 15 m flight length, and decay particles from K- pp are simultaneously measured by a cylindrical detector system that surrounds a liquid 3He target system. In March and May, 2013, we carried out the first physics data-taking with 5×109 incident kaons on the 3He target, and we have obtained a preliminary exclusive analysis result of 3He(K-, Λp)n reaction.

  10. Elastic proton scattering on tritium below the n-{sup 3}He threshold

    SciTech Connect

    Lazauskas, Rimantas

    2009-05-15

    Elastic proton scattering on the {sup 3}H nucleus is studied between p-{sup 3}H and n-{sup 3}He thresholds, in the energy region where the first excited state of the {alpha} particle is embedded in the continuum. Faddeev-Yakubovski equations are solved in configuration space by fully considering effects from isospin breaking and rigorously treating the Coulomb interaction. Different realistic nuclear Hamiltonians are tested, elucidating open problems in the description of the nuclear interaction.

  11. Collective Modes and f-Wave Pairing Interactions in Superfluid {sup 3}He

    SciTech Connect

    Davis, J. P.; Choi, H.; Pollanen, J.; Halperin, W. P.

    2006-09-15

    Precision measurements of collective mode frequencies in superfluid {sup 3}He-B are sensitive to quasiparticle and f-wave pairing interactions. Measurements were performed at various pressures using interference of transverse sound in an acoustic cavity. We fit the measured collective mode frequencies, which depend on the strength of f-wave pairing and the Fermi liquid parameter F{sub 2}{sup s}, to theoretical predictions and discuss what implications these values have for observing new order parameter collective modes.

  12. In vivo lung morphometry with hyperpolarized 3He diffusion MRI: Theoretical background

    NASA Astrophysics Data System (ADS)

    Sukstanskii, A. L.; Yablonskiy, D. A.

    2008-02-01

    MRI-based study of 3He gas diffusion in lungs may provide important information on lung microstructure. Lung acinar airways can be described in terms of cylinders covered with alveolar sleeve [Haefeli-Bleuer, Weibel, Anat. Rec. 220 (1988) 401]. For relatively short diffusion times (on the order of a few ms) this geometry allows description of the 3He diffusion attenuated MR signal in lungs in terms of two diffusion coefficients—longitudinal (D) and transverse (D) with respect to the individual acinar airway axis [Yablonskiy et al., PNAS 99 (2002) 3111]. In this paper, empirical relationships between D and D and the geometrical parameters of airways and alveoli are found by means of computer Monte Carlo simulations. The effects of non-Gaussian signal behavior (dependence of D and D on b-value) are also taken into account. The results obtained are quantitatively valid in the physiologically important range of airway parameters characteristic of healthy lungs and lungs with mild emphysema. In lungs with advanced emphysema, the results provide only "apparent" characteristics but still could potentially be used to evaluate emphysema progression. This creates a basis for in vivo lung morphometry—evaluation of the geometrical parameters of acinar airways from hyperpolarized 3He diffusion MRI, despite the airways being too small to be resolved by direct imaging. These results also predict a rather substantial dependence of 3He ADC on the experimentally-controllable diffusion time, Δ. If Δ is decreased from 3 ms to 1 ms, the ADC in normal human lungs may increase by almost 50%. This effect should be taken into account when comparing experimental data obtained with different pulse sequences.

  13. The Q^2 Evolution of the GDH sum Rule (on 3He and the Neutron)

    SciTech Connect

    Gordon Cates

    2002-06-01

    We discuss the extention of the Gerasimov-Drell-Hearn (GDH) sum rule, which pertains to real photons, to include scattering due to virtual photons. We present data from Jefferson Laboratory experiment E94-010 which measured the inclusive scattering of polarized electrons from a polarized 3He target over the quasielastic and resonance regions. From these data we exctract the transverse-transverse interference cross section {sigma}{prime}_TT', and compute the Q^2 depenent extended GDH integral.

  14. Maximum supercoolign in liquid /sup 3/He-/sup 4/He mixtures near the tricritical point

    SciTech Connect

    Sinha, D.N.; Hoffer, J.K.

    1984-01-01

    Measurements of supercooling in liquid /sup 3/He-/sup 4/He mixtures near the tricritical point are presented. The reduced temperature range 0.001 < epsilon identical to (1 - T/T/sub t/) < 0.01 was investigated for three different rates of cooling using a pressure-quench technique. For epsilon < 0.012, the maximum supercooling was found to be a function of the cooling rate. Comparisons with data in organic binary mixtures are given.

  15. Effect of confinement on phase-separation and superfluid transition in ^3 He-^4 He mixtures

    NASA Astrophysics Data System (ADS)

    Shenoy, V. B.; Saam, W. F.

    1996-03-01

    We derive the phase diagram of ^3 He - ^4 He mixtures confined between parallel plates within phenomelogical Landau theory. The analyses focus on the effect of the separation between the plates and the magnitude of surface field ( which is a measure of preference for ^4He rich phase) on phase-separation and superfluid transition in the confined mixtures. Connection to recent experiments on He mixtures in aerogel is made.

  16. Direct measurements of the magnetic field induced by optically polarized sup 3 He atoms

    SciTech Connect

    Gudoshnikov, S.A.; Snigirev, O.V. ); Kozlov, A.N.; Maslennikov, Y.V.; Serebrjakov, A.Y. )

    1991-03-01

    This paper reports on an alternative magnetic field induced by the standard cell of the optically pumped {sup 3}He magnetometer directly measured by the SQUID-based second-order gradiometer with signal-to-noise ratio higher than 6. The magnitude of the measured field equal to 5 {times} 10{sup {minus}13} T at the 5-cm distance from the cell axis and transverse relaxation time T{sub 2} equal to 7 minutes have been found.

  17. Study of the two-particle electrodisintegration of /sup 3/He

    SciTech Connect

    Gol'dshtein, V.A.; Kuplennikov, V.L.; Lubyanyi, V.V.; Startsev, V.I.; Shostak, V.B.; Afanas'ev, N.G.

    1980-05-01

    The /sup 3/He(e, e'p) reaction has been studied for momentum-transfer values 416 and 303 MeV/c. The two-particle and three-particle disintegration channels were separated. The results are compared with calculations based on several potentials and on a Gaussian bound-state wave function. Best agreement is obtained wih a Reid soft-core potential.

  18. Combination of a 3He/ 4He dilution refrigerator and an ESR spectrometer

    NASA Astrophysics Data System (ADS)

    von Spalden, Y.; Baberschke, K.

    1981-08-01

    We report the combination of a 3He/ 4He dilution refrigerator with ESR spectrometers of 1,3 and 9 GHz. Since only the sample is cooled down to Millikelvin, the microwave-frequency frequency setup can be changed very eaily during an experiment. The ESR intensities of a Au167 Er and a AuEr sample were used to calibrate the temperature of the sample.

  19. Calculation of Leggett-Takagi Relaxation in Vortices of Superfluid 3He-B

    NASA Astrophysics Data System (ADS)

    Laine, S. M.; Thuneberg, E. V.

    2016-05-01

    We calculate the relaxation of Brinkman-Smith mode via Leggett-Takagi relaxation in the presence of an isolated vortex in superfluid 3He-B. The calculation is based on an analytical solution of the order parameter far from the vortex axis. We obtain an expression for the dissipated power per vortex length as a function of the tipping angle of the magnetization and the orientation of the static magnetic field with respect to the vortex.

  20. Primary populations of metastable antiprotonic (4)He and (3)He atoms.

    PubMed

    Hori, M; Eades, J; Hayano, R S; Ishikawa, T; Sakaguchi, J; Tasaki, T; Widmann, E; Yamaguchi, H; Torii, H A; Juhász, B; Horváth, D; Yamazaki, T

    2002-08-26

    Initial distributions of metastable antiprotonic (4)He and (3)He atoms over principal (n) and angular momentum (l) quantum numbers have been deduced using laser spectroscopy experiments. The regions n = 37-40 and n = 35-38 in the two atoms account for almost all of the observed fractions [(3.0 +/- 0.1)% and (2.4 +/- 0.1)%] of antiprotons captured into metastable states. PMID:12190401