Recent preclinical and clinical studies indicate that irradiation using ionizing radiation in the dose range of 15 to 30 Gy may reduce the occurrence of restenosis in patients who have undergone an angioplasty. Several delivery systems of intravascular brachytherapy have been developed to deliver radiation doses in this range with minimal normal tissue ...
PubMed
The transfer of radiation therapy data among the various subsystems required for external beam treatments is subject to error. Hence, the establishment and management of a data transfer quality assurance program is strongly recommended. It should cover the QA of data transfers of patient specific treatments, imaging data, manually handled data and ...
The American Association of Physicists in Medicine (AAPM), a member society of the AIP is the largest professional society of medical physicists in the world with nearly 5700 members. Members operate in medical centers, university and community hospitals, research laboratories, industry, and private practice. Medical physics specialties include radiation ...
NASA Astrophysics Data System (ADS)
approach, the TomoTherapy system is based on the helical MV fan beam(23,24) . Although the radiation dose�61 (2006). 23. Mackie, T. R. History of tomotherapy. Phys. Med. Biol. 51, 427�453 (2006). 24. Langen, K. M
E-print Network
This article reviews the involvement of the AAPM in various aspects of radiation dosimetry over its 50 year history, emphasizing the especially important role that external beam dosimetry played in the early formation of the organization. Topics covered include the AAPM's involvement with external beam and x-ray dosimetry ...
Energy Citations Database
Recent developments in radiation therapy have immensely impacted the way the radiation dose is delivered to patients undergoing radiation treatments. However, the fundamental quality assurance (QA) issues underlying the radiation therapy still remain the accuracy of the ...
This book is the fifth in a series of monographs by the American Association of Physicists in Medicine (AAPM) and is a compendium of papers presented at an AAPM regional symposium conducted in San Antonio in July 1980. The book is divided into three sections: (1) biological fundamentals of ionizing radiation, (2) risk evaluation and ...
This report is an extension of the 1983 AAPM protocol, popularly known as the TG-21 Protocol. It deals with the calibration of plane-parallel ionization chambers and their use in calibrating therapy electron beams. A hierarchy of methods is presented. The first is to calibrate the plane-parallel chamber in a high energy electron beam against a cylindrical ...
The custody, maintenance, and development of the United States national standards of measurement, together with the provision of calibration services related to these standards, has been assigned to the National Bureau of Standards (NBS) of the U. S. Department of Commerce. It may be that the present system of promulgation of radiation standards is no longer adequate for the ...
This document is the report of a task group of the AAPM and has been prepared primarily to advise medical physicists involved in the external-beam radiation therapy of patients with thoracic, abdominal, and pelvic tumors affected by respiratory motion. This report describes the magnitude of respiratory motion, discusses radiotherapy ...
The panel discussion will explore opportunities and vistas in medical physics research and practice, medical imaging, teaching medical physics to undergraduates, and medical physics curricula as a recruiting tool for physics departments. Panel members consist of representatives from NSBP (Paul Gu�ye and Steven Avery), NIH/NIBIB (Richard Baird), NIST (Christopher Soares), ...
Medical products (devices, drugs, or biologics) contain information in their labeling regarding the manner in which the manufacturer has determined that the products can be used in a safe and effective manner. The Food and Drug Administration (FDA) approves medical products for use for these specific indications which are part of the medical product's labeling. When medical products are used in a ...
The increasing complexity of modern radiation therapy planning and delivery techniques challenges traditional prescriptive quality control and quality assurance programs that ensure safety and reliability of treatment planning and delivery systems under all clinical scenarios. Until now quality management (QM) guidelines published by concerned ...
This work reports the transfer of the primary standard for air kerma from the National Institute of Standards and Technology (NIST) to the secondary laboratories accredited by the American Association of Physics in Medicine (AAPM). This transfer, performed in August of 2003, was motivated by the recent revision of the NIST air-kerma standards for {sup 60}Co gamma-ray beams ...
The publication of AAPM Report No. 10 was the first attempt to standardize image formats in the medical imaging community. Since then, three other groups have formed (CART--the Scandinavian collaboration for Computer Assisted Radiation Therapy treatment planning; ACR-NEMA, a collaboration whose purpose is to formulate a standard ...
The Monte Carlo method enables accurate dose calculation for radiation therapy treatment planning and has been implemented in some commercial treatment planning systems. Unlike conventional dose calculation algorithms that provide patient dose information in terms of dose to water with variable electron density, the Monte Carlo method calculates the energy ...
The medical physicist is a professional who specializes in the application of the concepts and methods of physics to the diagnosis and treatment of human disease. Medical physicists identify their primary discipline to be radiation therapy (78%), medical imaging (16%), nuclear medicine (3%), or radiation safety (2%). They state their ...
Since publication of the 2004 update to the American Association of Physicists in Medicine (AAPM) Task Group No. 43 Report (TG-43U1), several new low-energy photon-emitting brachytherapy sources have become available. Many of these sources have satisfied the AAPM prerequisites for routine clinical use as of January 10, 2005, and are posted on the Joint ...
... and A study of the metabolic aspects of therapy of radiation injury in the soldier. Descriptors : *RADIATION INJURIES, THERAPY, RADIATION ...
DTIC Science & Technology
The major feature that separates stereotactic radiation therapy (cranial SRT) and stereotactic body radiation therapy (SBRT) from conventional radiation treatment is the delivery of large doses in a few fractions which results in a high biological effective dose (BED). In order to minimize the ...
... Title : Radiation Chimeras and Therapy of Radiation Injuries - USSR -. ... Abstract : Radiation chimeras and therapy of radiation injuries are discussed. ...
A Histogram Analysis in Radiation Therapy (HART) program was primarily developed to increase the efficiency and accuracy of dose�volume histogram (DVH) analysis of large quantities of patient data in radiation therapy research. The program was written in MATLAB to analyze patient plans exported from the treatment ...
PubMed Central
... New therapies are combined with conventional treatment; radiation therapy is a standard therapy for breast cancer. There ...
The Radiological Physics Center (RPC) was established upon the recommendation of the Committee on Radiation Therapy Studies (CRTS), now the Committee on Radiation Oncology Studies (CROS), under the sponsorship of the American Association of Physicists in Medicine (AAPM) to insure the correctness and consistency of ...
This report summarizes the consensus findings and recommendations emerging from 2007 Symposium, 'Quality Assurance of Radiation Therapy: Challenges of Advanced Technology.' The Symposium was held in Dallas February 20-22, 2007. The 3-day program, which was sponsored jointly by the American Society for Therapeutic Radiology and Oncology ...
This report summarizes the consensus findings and recommendations emerging from 2007 Symposium, "Quality Assurance of Radiation Therapy: Challenges of Advanced Technology." The Symposium was held in Dallas February 20-22, 2007. The 3-day program, which was sponsored jointly by the American Society for Therapeutic Radiology and Oncology (ASTRO), American ...
Dose calculations to patients undergoing implantation of 125I interstitial brachytherapy sources are affected by two recent changes in low-energy seed dosimetry: (a) implantation of a new primary air-kerma strength standard at the National Institute of Standards and Technology (NIST) on 1 January 1999 and (b) publication of revised dose-rate distributions in AAPM's Task Group ...
Task Group 6 of the Diagnostic X-Ray Imaging Committee of the American Association of Physicists in Medicine (AAPM) was appointed to develop performance standards for diagnostic x-ray exposure meters. The recommendations as approved by the Diagnostic X-Ray Imaging Committee and the Science Council of the AAPM are delineated in this report and provide ...
Helical tomotherapy is a relatively new modality with integrated treatment planning and delivery hardware for radiation therapy treatments. In view of the uniqueness of the hardware design of the helical tomotherapy unit and its implications in routine quality assurance, the Therapy Physics Committee of the American Association of ...
The goal of Task Group 25 (TG-25) of the Radiation Therapy Committee of the American Association of.Physicists in Medicine (AAPM) was to provide a methodology and set of procedures for a medical physicist performing clinical electron beam dosimetry in the nominal energy range of 5-25 MeV. Specifically, the task group recommended ...
Monte Carlo simulations for radiation dosimetry and the experimental verifications of the simulations have been developed for the treatment geometry of intravascular brachytherapy, a form of radionuclide therapy for occluded coronary disease (restenosis). Monte Carlo code, MCNP4C, has been used to calculate the radiation dose from the ...
DOE Information Bridge
Professions in: Radiation Therapy Radiation Oncologist Medical Radiation Physicist Radiation Therapist Dosimetrist Radiation Oncology Nurse Social Worker ...
MedlinePLUS
The technical aspects of quality assurance (QA) in radiation oncology as practice in the United States will be reviewed and updated in the spirit of offering the experience to the radiation oncology communities in the Asia-Pacific region. The word �technical� is used to express the organisational components or processes and not the materials within the ...
A carcinoma is a malignant cancer that emerges from epithelial cells in structures through out the body.It invades the critical organs, could metastasize or spread to lymph nodes.IMRT is an advanced mode of radiation therapy treatment for cancer. It delivers more conformal doses to malignant tumors sparing the critical organs by modulating the intensity of ...
The task group (TG) for quality assurance for robotic radiosurgery was formed by the American Association of Physicists in Medicine's Science Council under the direction of the Radiation Therapy Committee and the Quality Assurance (QA) Subcommittee. The task group (TG-135) had three main charges: (1) To make recommendations on a code of practice for ...
AAPM Radiation Therapy Committee Task Group 25 has recently outlined a protocol for the determination of relative dose curves for electron beams [Med. Phys. 18, 73-109 (1991)]. We have performed an evaluation of this protocol by comparing the central axis depth dose curves determined from measurements using two different ionization ...
... Syndrome in Acute Radiation Injury and an annotated ... METABOLISM, *RADIATION EFFECTS, *RADIATION INJURIES, THERAPY, PATHOLOGY ...
... Quick Links How Does Radiation Therapy Work? External Beam Radiation Therapy Brachytherapy Stereotactic Radiation Therapy Additional Treatment ... radiation. Intraoperative radiation can be given as external beam ...
Volumetric modulated arc therapy (VMAT) has recently emerged as a new clinical modality for conformal radiation therapy. The aim of this work is to establish a methodology and procedure for retrospectively reconstructing the actual dose delivered in VMAT based on the pre-treatment cone-beam computed tomography (CBCT) and dynamic log ...
In recent years, the Monte Carlo method has been used in a large number of research studies in radiation therapy. For applications such as treatment planning, it is essential to validate the dosimetric accuracy of the Monte Carlo simulations in heterogeneous media. The AAPM Report no 105 addresses issues concerning clinical ...