Sample records for abbn-90 constant system

  1. Testing of the ABBN-RF multigroup data library in photon transport calculations

    NASA Astrophysics Data System (ADS)

    Koscheev, Vladimir; Lomakov, Gleb; Manturov, Gennady; Tsiboulia, Anatoly

    2017-09-01

    Gamma radiation is produced via both of nuclear fuel and shield materials. Photon interaction is known with appropriate accuracy, but secondary gamma ray production known much less. The purpose of this work is studying secondary gamma ray production data from neutron induced reactions in iron and lead by using MCNP code and modern nuclear data as ROSFOND, ENDF/B-7.1, JEFF-3.2 and JENDL-4.0. Results of calculations show that all of these nuclear data have different photon production data from neutron induced reactions and have poor agreement with evaluated benchmark experiment. The ABBN-RF multigroup cross-section library is based on the ROSFOND data. It presented in two forms of micro cross sections: ABBN and MATXS formats. Comparison of group-wise calculations using both ABBN and MATXS data to point-wise calculations with the ROSFOND library shows a good agreement. The discrepancies between calculation and experimental C/E results in neutron spectra are in the limit of experimental errors. For the photon spectrum they are out of experimental errors. Results of calculations using group-wise and point-wise representation of cross sections show a good agreement both for photon and neutron spectra.

  2. 40 CFR 86.519-90 - Constant volume sampler calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 19 2013-07-01 2013-07-01 false Constant volume sampler calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.519-90 Constant volume sampler calibration. (a) The CVS (Constant Volume Sampler) is calibrated using an accurate flowmeter and restrictor...

  3. 40 CFR 86.519-90 - Constant volume sampler calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Constant volume sampler calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.519-90 Constant volume sampler calibration. (a) The CVS (Constant Volume Sampler) is calibrated using an accurate flowmeter and restrictor...

  4. 40 CFR 86.519-90 - Constant volume sampler calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Constant volume sampler calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.519-90 Constant volume sampler calibration. (a) The CVS (Constant Volume Sampler) is calibrated using an accurate flowmeter and restrictor...

  5. 40 CFR 86.519-90 - Constant volume sampler calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Constant volume sampler calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.519-90 Constant volume sampler calibration. (a) The CVS (Constant Volume Sampler) is calibrated using an accurate flowmeter and restrictor...

  6. 40 CFR 86.519-90 - Constant volume sampler calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Constant volume sampler calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.519-90 Constant volume sampler calibration. (a) The CVS (Constant Volume Sampler) is calibrated using an accurate flowmeter and restrictor...

  7. Nuclide radioactive decay data uncertainties library

    NASA Astrophysics Data System (ADS)

    Barabanova, D. S.; Zherdev, G. M.

    2017-01-01

    The results of the developing the library of uncertainties of radioactive decay data in the ABBN data library format are described. Different evaluations of uncertainties were compared and their effects on the results of calculations of residual energy release were determined using the test problems and experiment. Tables were generated in the ABBN format with the data obtained on the basis of libraries in ENDF-6 format. 3821 isotopes from the ENDF/B-7 data library, 3852 isotopes from the JEFF-3.11 data library and 1264 isotopes from the JENDL-4.0 data library were processed. It was revealed that the differences in the evaluations accepted in different decay data libraries are not so big, although they sometimes exceed the uncertainties assigned to the data in the ENDF/B-7 and JEFF-3.11 libraries, which as a rule, they agree with each other. On the basis of developed method it is supposed to create a library of data uncertainties for radioactive decay within the constant data system in FSUE RFNC-VNIIEF with its further connection with CRYSTAL module.

  8. 40 CFR 90.327 - Sampling system requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Sampling system requirements. 90.327... Equipment Provisions § 90.327 Sampling system requirements. (a) Sample component surface temperature. For sampling systems which use heated components, use engineering judgment to locate the coolest portion of...

  9. 40 CFR 90.327 - Sampling system requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Sampling system requirements. 90.327... Equipment Provisions § 90.327 Sampling system requirements. (a) Sample component surface temperature. For sampling systems which use heated components, use engineering judgment to locate the coolest portion of...

  10. 40 CFR 90.307 - Engine cooling system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine cooling system. 90.307 Section...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Emission Test Equipment Provisions § 90.307 Engine cooling system. An engine cooling system is required with sufficient capacity to...

  11. 40 CFR 90.307 - Engine cooling system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine cooling system. 90.307 Section...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Emission Test Equipment Provisions § 90.307 Engine cooling system. An engine cooling system is required with sufficient capacity to...

  12. 40 CFR 90.307 - Engine cooling system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine cooling system. 90.307 Section...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Emission Test Equipment Provisions § 90.307 Engine cooling system. An engine cooling system is required with sufficient capacity to...

  13. Groundwater transport of strontium 90 in a glacial outwash environment

    USGS Publications Warehouse

    Kipp, Kenneth L.; Stollenwerk, Kenneth G.; Grove, David B.

    1986-01-01

    As part of the investigation of groundwater contamination at a uranium-scrap recovery plant at Wood River Junction, Rhode Island, laboratory experiments led to the development of a model for predicting the transport of strontium 90 in glacial outwash sediments based on an approximate mechanism for ion exchange. The multicomponent system was simplified to two components by regarding all exchangeable cations other than strontium 90 as a single component. The binary ion-exchange parameter was a function of the variable, total ion concentration. A one-dimensional solute transport model was formulated to evaluate the time necessary for natural groundwater flow to remove the strontium 90 contamination plume from the groundwater system to the Pawcatuck River. The finite difference transport equations were solved sequentially for total ion concentrations, then strontium 90 concentrations. Clay-free quartz and feldspar sands at the study site have little potential for strontium 90 sorption, and high calcium, magnesium, and sodium concentrations compete for the few ion exchange sites. As the total ion concentration plume moves out of the system, ion exchange of strontium 90 increases, reducing the strontium 90 concentration in the groundwater. Cleanout times predicted using the binary ion exchange mechanism were about two thirds of those predicted using a constant distribution coefficient. It is suggested that this type of model can simulate solute transport more realistically in many groundwater systems where the total ion concentration is not constant.

  14. Dielectric-constant gas thermometry

    NASA Astrophysics Data System (ADS)

    Gaiser, Christof; Zandt, Thorsten; Fellmuth, Bernd

    2015-10-01

    The principles, techniques and results from dielectric-constant gas thermometry (DCGT) are reviewed. Primary DCGT with helium has been used for measuring T-T90 below the triple point of water (TPW), where T is the thermodynamic temperature and T90 is the temperature on the international temperature scale of 1990 (ITS-90), and, in an inverse regime with T as input quantity, for determining the Boltzmann constant at the TPW. Furthermore, DCGT allows the determination of several important material properties including the polarizability of neon and argon as well as the virial coefficients of helium, neon, and argon. With interpolating DCGT (IDCGT), the ITS-90 has been approximated in the temperature range from 4 K to 25 K. An overview and uncertainty budget for each of these applications of DCGT is provided, accompanied by corroborating evidence from the literature or, for IDCGT, a CIPM key comparison.

  15. Measurement of Nanomolar Dissociation Constants by Titration Calorimetry and Thermal Shift Assay – Radicicol Binding to Hsp90 and Ethoxzolamide Binding to CAII

    PubMed Central

    Zubrienė, Asta; Matulienė, Jurgita; Baranauskienė, Lina; Jachno, Jelena; Torresan, Jolanta; Michailovienė, Vilma; Cimmperman, Piotras; Matulis, Daumantas

    2009-01-01

    The analysis of tight protein-ligand binding reactions by isothermal titration calorimetry (ITC) and thermal shift assay (TSA) is presented. The binding of radicicol to the N-terminal domain of human heat shock protein 90 (Hsp90αN) and the binding of ethoxzolamide to human carbonic anhydrase (hCAII) were too strong to be measured accurately by direct ITC titration and therefore were measured by displacement ITC and by observing the temperature-denaturation transitions of ligand-free and ligand-bound protein. Stabilization of both proteins by their ligands was profound, increasing the melting temperature by more than 10 ºC, depending on ligand concentration. Analysis of the melting temperature dependence on the protein and ligand concentrations yielded dissociation constants equal to 1 nM and 2 nM for Hsp90αN-radicicol and hCAII-ethoxzolamide, respectively. The ligand-free and ligand-bound protein fractions melt separately, and two melting transitions are observed. This phenomenon is especially pronounced when the ligand concentration is equal to about half the protein concentration. The analysis compares ITC and TSA data, accounts for two transitions and yields the ligand binding constant and the parameters of protein stability, including the Gibbs free energy and the enthalpy of unfolding. PMID:19582223

  16. Kepler-90 system (Artist's Concept)

    NASA Image and Video Library

    2017-12-14

    Our solar system now is tied for most number of planets around a single star, with the recent discovery of an eighth planet circling Kepler-90, a Sun-like star 2,545 light years from Earth. The planet was discovered in data from NASA's Kepler Space Telescope. The newly-discovered Kepler-90i -- a sizzling hot, rocky planet that orbits its star once every 14.4 days -- was found using machine learning from Google. Machine learning is an approach to artificial intelligence in which computers "learn." In this case, computers learned to identify planets by finding in Kepler data instances where the telescope recorded changes in starlight caused by planets beyond our solar system, known as exoplanets. https://photojournal.jpl.nasa.gov/catalog/PIA22192

  17. CRISP90 - SOFTWARE DESIGN ANALYZER SYSTEM

    NASA Technical Reports Server (NTRS)

    Tausworthe, R. C.

    1994-01-01

    The CRISP90 Software Design Analyzer System, an update of CRISP-80, is a set of programs forming a software design and documentation tool which supports top-down, hierarchic, modular, structured design and programming methodologies. The quality of a computer program can often be significantly influenced by the design medium in which the program is developed. The medium must foster the expression of the programmer's ideas easily and quickly, and it must permit flexible and facile alterations, additions, and deletions to these ideas as the design evolves. The CRISP90 software design analyzer system was developed to provide the PDL (Programmer Design Language) programmer with such a design medium. A program design using CRISP90 consists of short, English-like textual descriptions of data, interfaces, and procedures that are imbedded in a simple, structured, modular syntax. The display is formatted into two-dimensional, flowchart-like segments for a graphic presentation of the design. Together with a good interactive full-screen editor or word processor, the CRISP90 design analyzer becomes a powerful tool for the programmer. In addition to being a text formatter, the CRISP90 system prepares material that would be tedious and error prone to extract manually, such as a table of contents, module directory, structure (tier) chart, cross-references, and a statistics report on the characteristics of the design. Referenced modules are marked by schematic logic symbols to show conditional, iterative, and/or concurrent invocation in the program. A keyword usage profile can be generated automatically and glossary definitions inserted into the output documentation. Another feature is the capability to detect changes that were made between versions. Thus, "change-bars" can be placed in the output document along with a list of changed pages and a version history report. Also, items may be marked as "to be determined" and each will appear on a special table until the item is

  18. Kepler-90 System Compared to Our Solar System (Artist's Concept)

    NASA Image and Video Library

    2017-12-14

    Our solar system now is tied for most number of planets around a single star, with the recent discovery of an eighth planet circling Kepler-90, a Sun-like star 2,545 light years from Earth. The planet was discovered in data from NASA's Kepler Space Telescope. This artist's concept depicts the Kepler-90 system compared with our own solar system. The newly-discovered Kepler-90i -- a sizzling hot, rocky planet that orbits its star once every 14.4 days -- was found using machine learning from Google. Machine learning is an approach to artificial intelligence in which computers "learn." In this case, computers learned to identify planets by finding in Kepler data instances where the telescope recorded changes in starlight caused by planets beyond our solar system, known as exoplanets. https://photojournal.jpl.nasa.gov/catalog/PIA22193

  19. A Fortran-90 Based Multiprecision System

    NASA Technical Reports Server (NTRS)

    Bailey, David H.; Lasinski, T. A. (Technical Monitor)

    1994-01-01

    The author has developed a new version of his Fortran multiprecision computation system that is based on the Fortran-90 language. With this new approach, a translator program is not required - translation of Fortran code for multiprecision is accomplished by merely utilizing advanced features of Fortran-90, such as derived data types and operator extensions. This approach results in more reliable translation and also permits programmers of multiprecision applications to utilize the full power of the Fortran-90 language. Three multiprecision datatypes are supported in this system: multiprecision integer. real and complex. All the usual Fortran conventions for mixed mode operations are supported, and many of the Fortran intrinsics, such as SIN, EXP and MOD, are supported with multiprecision arguments. This paper also briefly describes an interesting application of this software, wherein new number-theoretic identities have been discovered by means of multiprecision computations.

  20. 47 CFR 90.465 - Control of systems of communication.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Control of systems of communication. 90.465 Section 90.465 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control § 90.465 Control of systems of communication. (a) Depending on design considerations...

  1. Optical constants of liquid and solid methane

    NASA Technical Reports Server (NTRS)

    Martonchik, John V.; Orton, Glenn S.

    1994-01-01

    The optical constants n(sub r) + in(sub i) of liquid methane and phase 1 solid methane were determined over the entire spectral range by the use of various data sources published in the literature. Kramers-Kronig analyses were performed on the absorption spectra of liquid methane at the boiling point (111 K) and the melting point (90 K) and on the absorption spectra of phase 1 solid methane at the melting point and at 30 K. Measurements of the static dielectric constant at these temperatures and refractive indices determined over limited spectral ranges were used as constraints in the analyses. Applications of methane optical properties to studies of outer solar system bodies are described.

  2. 40 CFR 86.509-90 - Exhaust gas sampling system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Exhaust gas sampling system. 86.509-90... 1978 and Later New Motorcycles; Test Procedures § 86.509-90 Exhaust gas sampling system. (a)(1) General. The exhaust gas sampling system is designed to measure the true mass emissions of vehicle exhaust. In...

  3. 40 CFR 86.509-90 - Exhaust gas sampling system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Exhaust gas sampling system. 86.509-90... 1978 and Later New Motorcycles; Test Procedures § 86.509-90 Exhaust gas sampling system. (a)(1) General. The exhaust gas sampling system is designed to measure the true mass emissions of vehicle exhaust. In...

  4. 42 CFR 414.90 - Physician Quality Reporting System.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 3 2011-10-01 2011-10-01 false Physician Quality Reporting System. 414.90 Section 414.90 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM PAYMENT FOR PART B MEDICAL AND OTHER HEALTH SERVICES Physicians and Other...

  5. Helicopter TEM parameters analysis and system optimization based on time constant

    NASA Astrophysics Data System (ADS)

    Xiao, Pan; Wu, Xin; Shi, Zongyang; Li, Jutao; Liu, Lihua; Fang, Guangyou

    2018-03-01

    Helicopter transient electromagnetic (TEM) method is a kind of common geophysical prospecting method, widely used in mineral detection, underground water exploration and environment investigation. In order to develop an efficient helicopter TEM system, it is necessary to analyze and optimize the system parameters. In this paper, a simple and quantitative method is proposed to analyze the system parameters, such as waveform, power, base frequency, measured field and sampling time. A wire loop model is used to define a comprehensive 'time constant domain' that shows a range of time constant, analogous to a range of conductance, after which the characteristics of the system parameters in this domain is obtained. It is found that the distortion caused by the transmitting base frequency is less than 5% when the ratio of the transmitting period to the target time constant is greater than 6. When the sampling time window is less than the target time constant, the distortion caused by the sampling time window is less than 5%. According to this method, a helicopter TEM system, called CASHTEM, is designed, and flight test has been carried out in the known mining area. The test results show that the system has good detection performance, verifying the effectiveness of the method.

  6. 47 CFR 90.691 - Emission mask requirements for EA-based systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Emission mask requirements for EA-based systems. 90.691 Section 90.691 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND... of Ea-Based Smr Systems in the 809-824/851-869 Mhz Band § 90.691 Emission mask requirements for EA...

  7. 21 CFR 1250.42 - Water systems; constant temperature bottles.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... reconstructed conveyances, water coolers shall be an integral part of the closed system. (d) Water filters if... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Water systems; constant temperature bottles. 1250... INTERSTATE CONVEYANCE SANITATION Equipment and Operation of Land and Air Conveyances § 1250.42 Water systems...

  8. 21 CFR 1250.42 - Water systems; constant temperature bottles.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... reconstructed conveyances, water coolers shall be an integral part of the closed system. (d) Water filters if... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Water systems; constant temperature bottles. 1250... INTERSTATE CONVEYANCE SANITATION Equipment and Operation of Land and Air Conveyances § 1250.42 Water systems...

  9. Constant-pH Molecular Dynamics Simulations for Large Biomolecular Systems

    DOE PAGES

    Radak, Brian K.; Chipot, Christophe; Suh, Donghyuk; ...

    2017-11-07

    We report that an increasingly important endeavor is to develop computational strategies that enable molecular dynamics (MD) simulations of biomolecular systems with spontaneous changes in protonation states under conditions of constant pH. The present work describes our efforts to implement the powerful constant-pH MD simulation method, based on a hybrid nonequilibrium MD/Monte Carlo (neMD/MC) technique within the highly scalable program NAMD. The constant-pH hybrid neMD/MC method has several appealing features; it samples the correct semigrand canonical ensemble rigorously, the computational cost increases linearly with the number of titratable sites, and it is applicable to explicit solvent simulations. The present implementationmore » of the constant-pH hybrid neMD/MC in NAMD is designed to handle a wide range of biomolecular systems with no constraints on the choice of force field. Furthermore, the sampling efficiency can be adaptively improved on-the-fly by adjusting algorithmic parameters during the simulation. Finally, illustrative examples emphasizing medium- and large-scale applications on next-generation supercomputing architectures are provided.« less

  10. Constant-pH Molecular Dynamics Simulations for Large Biomolecular Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radak, Brian K.; Chipot, Christophe; Suh, Donghyuk

    We report that an increasingly important endeavor is to develop computational strategies that enable molecular dynamics (MD) simulations of biomolecular systems with spontaneous changes in protonation states under conditions of constant pH. The present work describes our efforts to implement the powerful constant-pH MD simulation method, based on a hybrid nonequilibrium MD/Monte Carlo (neMD/MC) technique within the highly scalable program NAMD. The constant-pH hybrid neMD/MC method has several appealing features; it samples the correct semigrand canonical ensemble rigorously, the computational cost increases linearly with the number of titratable sites, and it is applicable to explicit solvent simulations. The present implementationmore » of the constant-pH hybrid neMD/MC in NAMD is designed to handle a wide range of biomolecular systems with no constraints on the choice of force field. Furthermore, the sampling efficiency can be adaptively improved on-the-fly by adjusting algorithmic parameters during the simulation. Finally, illustrative examples emphasizing medium- and large-scale applications on next-generation supercomputing architectures are provided.« less

  11. 47 CFR 90.655 - Special licensing requirements for Specialized Mobile Radio systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Mobile Radio systems. 90.655 Section 90.655 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Regulations Governing... Bands § 90.655 Special licensing requirements for Specialized Mobile Radio systems. End users of...

  12. 47 CFR 90.471 - Points of operation in internal transmitter control systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Points of operation in internal transmitter control systems. 90.471 Section 90.471 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control Systems § 90.471 Points of...

  13. 47 CFR 90.471 - Points of operation in internal transmitter control systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Points of operation in internal transmitter control systems. 90.471 Section 90.471 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control Systems § 90.471 Points of...

  14. 47 CFR 90.471 - Points of operation in internal transmitter control systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Points of operation in internal transmitter control systems. 90.471 Section 90.471 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control Systems § 90.471 Points of...

  15. 47 CFR 90.471 - Points of operation in internal transmitter control systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Points of operation in internal transmitter control systems. 90.471 Section 90.471 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control Systems § 90.471 Points of...

  16. 47 CFR 90.471 - Points of operation in internal transmitter control systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Points of operation in internal transmitter control systems. 90.471 Section 90.471 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control Systems § 90.471 Points of...

  17. 47 CFR 90.359 - Field strength limits for EA-licensed LMS systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Field strength limits for EA-licensed LMS systems. 90.359 Section 90.359 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Intelligent Transportation Systems Radio Service § 90.359 Field strength limits for...

  18. 47 CFR 90.633 - Conventional systems loading requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of need. In a ribbon, regional or statewide system, a mobile station will be counted for channel... 47 Telecommunication 5 2011-10-01 2011-10-01 false Conventional systems loading requirements. 90... RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Regulations Governing Licensing and Use of Frequencies...

  19. 47 CFR 90.656 - Responsibilities of base station licensees of Specialized Mobile Radio systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... operate mobile units on a particular Specialized Mobile Radio system will be licensed to that system. A... Specialized Mobile Radio systems. 90.656 Section 90.656 Telecommunication FEDERAL COMMUNICATIONS COMMISSION... Bands § 90.656 Responsibilities of base station licensees of Specialized Mobile Radio systems. (a) The...

  20. STRONTIUM 90: ESTIMATION OF WORLDWIDE DEPOSITION.

    PubMed

    VOLCHOK, H L

    1964-09-25

    The relation between the worldwide deposition of strontium-90, as calculated by many investigators over the last decade, and that observed in rainfall in New York City has been relatively constant. On the average, for each millicurie of strontium-90 per square mile deposited in New York City, 0.055 megacurie has been deposited on the earth's total surface. Cumulative deposits of strontium-90 on the earth's surface at various intervals over the last 10 years have been computed from this ratio. From the mean quarterly fraction of the annual strontium-90 fallout in New York City for the last 9 years, the worldwide deposition of this nuclide, equal to 2.48 megacuries, is predicted for 1964.

  1. Contact position sensor using constant contact force control system

    NASA Technical Reports Server (NTRS)

    Sturdevant, Jay (Inventor)

    1995-01-01

    A force control system (50) and method are provided for controlling a position contact sensor (10) so as to produce a constant controlled contact force therewith. The system (50) includes a contact position sensor (10) which has a contact probe (12) for contacting the surface of a target to be measured and an output signal (V.sub.o) for providing a position indication thereof. An actuator (30) is provided for controllably driving the contact position sensor (10) in response to an actuation control signal (I). A controller (52) receives the position indication signal (V.sub.o) and generates in response thereto the actuation control signal (I) so as to provide a substantially constant selective force (F) exerted by the contact probe (12). The actuation drive signal (I) is generated further in response to substantially linear approximation curves based on predetermined force and position data attained from the sensor (10) and the actuator (30).

  2. 21 CFR 1250.42 - Water systems; constant temperature bottles.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Water systems; constant temperature bottles. 1250.42 Section 1250.42 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) REGULATIONS UNDER CERTAIN OTHER ACTS ADMINISTERED BY THE FOOD AND DRUG ADMINISTRATION...

  3. 47 CFR 90.357 - Frequencies for LMS systems in the 902-928 MHz band.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Frequencies for LMS systems in the 902-928 MHz band. 90.357 Section 90.357 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Intelligent Transportation Systems Radio Service § 90.357 Frequencies for LMS systems in...

  4. 21 CFR 1250.42 - Water systems; constant temperature bottles.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Water systems; constant temperature bottles. 1250.42 Section 1250.42 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) REGULATIONS UNDER CERTAIN OTHER ACTS ADMINISTERED BY THE FOOD AND DRUG ADMINISTRATION INTERSTATE CONVEYANCE SANITATION Equipment and...

  5. Inflation with a smooth constant-roll to constant-roll era transition

    NASA Astrophysics Data System (ADS)

    Odintsov, S. D.; Oikonomou, V. K.

    2017-07-01

    In this paper, we study canonical scalar field models, with a varying second slow-roll parameter, that allow transitions between constant-roll eras. In the models with two constant-roll eras, it is possible to avoid fine-tunings in the initial conditions of the scalar field. We mainly focus on the stability of the resulting solutions, and we also investigate if these solutions are attractors of the cosmological system. We shall calculate the resulting scalar potential and, by using a numerical approach, we examine the stability and attractor properties of the solutions. As we show, the first constant-roll era is dynamically unstable towards linear perturbations, and the cosmological system is driven by the attractor solution to the final constant-roll era. As we demonstrate, it is possible to have a nearly scale-invariant power spectrum of primordial curvature perturbations in some cases; however, this is strongly model dependent and depends on the rate of the final constant-roll era. Finally, we present, in brief, the essential features of a model that allows oscillations between constant-roll eras.

  6. Converting Constant Volume, Multizone Air Handling Systems to Energy Efficient Variable Air Volume Multizone Systems

    DTIC Science & Technology

    2017-10-26

    1 FINAL REPORT Converting Constant Volume, Multizone Air Handling Systems to Energy Efficient Variable Air Volume Multizone...Systems Energy and Water Projects Project Number: EW-201152 ERDC-CERL 26 October 2017 2 TABLE OF CONTENTS ACKNOWLEDGEMENTS...16 3.2.1 Energy Usage (Quantitative

  7. Constant light during lactation programs circadian and metabolic systems.

    PubMed

    Madahi, Palma-Gómez; Ivan, Osnaya; Adriana, Balderas; Diana, Ortega; Carolina, Escobar

    2018-04-24

    Exposure to light at night is a disruptive condition for the adult circadian system, leading to arrhythmicity in nocturnal rodents. Circadian disruption is a risk factor for developing physiological and behavioral alterations, including weight gain and metabolic disease. During early stages of development, the circadian system undergoes a critical period of adjustment, and it is especially vulnerable to altered lighting conditions that may program its function, leading to long-term effects. We hypothesized that during lactation a disrupted light-dark cycle due to light at night may disrupt the circadian system and in the long term induce metabolic disorders. Here we explored in pups, short- and long-term effects of constant light (LL) during lactation. In the short term, LL caused a loss of rhythmicity and a reduction in the immunopositive cells of VIP, AVP, and PER1 in the suprachiasmatic nucleus (SCN). In the short term, the affection on the circadian clock in the pups resulted in body weight gain, loss of daily rhythms in general activity, plasma glucose and triglycerides (TG). Importantly, the DD conditions during development also induced altered daily rhythms in general activity and in the SCN. Exposure to LD conditions after lactation did not restore rhythmicity in the SCN, and the number of immunopositve cells to VIP, AVP, and PER1 remained reduced. In the long term, daily rhythmicity in general activity was restored; however, daily rhythms in glucose and TG remained disrupted, and daily mean levels of TG were significantly increased. Present results point out the programming role played by the LD cycle during early development in the function of the circadian system and on metabolism. This study points out the risk represented by exposure to an altered light-dark cycle during early stages of development. AVP: arginine vasopressin peptide; CRY: cryptochrome; DD: constant darkness; DM: dorsomedial; LD: light-dark cycle; LL: constant light; NICUs: neonatal

  8. Prediction of Rate Constant for Supramolecular Systems with Multiconfigurations.

    PubMed

    Guo, Tao; Li, Haiyan; Wu, Li; Guo, Zhen; Yin, Xianzhen; Wang, Caifen; Sun, Lixin; Shao, Qun; Gu, Jingkai; York, Peter; Zhang, Jiwen

    2016-02-25

    The control of supramolecular systems requires a thorough understanding of their dynamics, especially on a molecular level. It is extremely difficult to determine the thermokinetic parameters of supramolecular systems, such as drug-cyclodextrin complexes with fast association/dissociation processes by experimental techniques. In this paper, molecular modeling combined with novel mathematical relationships integrating the thermodynamic/thermokinetic parameters of a series of isomeric multiconfigurations to predict the overall parameters in a range of pH values have been employed to study supramolecular dynamics at the molecular level. A suitable form of Eyring's equation was derived and a two-stage model was introduced. The new approach enabled accurate prediction of the apparent dissociation/association (k(off)/k(on)) and unbinding/binding (k-r/kr) rate constants of the ubiquitous multiconfiguration complexes of the supramolecular system. The pyronine Y (PY) was used as a model system for the validation of the presented method. Interestingly, the predicted k(off) value ((40 ± 1) × 10(5) s(-1), 298 K) of PY is largely in agreement with that previously determined by fluorescence correlation spectroscopy ((5 ± 3) × 10(5) s(-1), 298 K). Moreover, the k(off)/k(on) and k-r/kr for flurbiprofen-β-cylcodextrin and ibuprofen-β-cyclodextrin systems were also predicted and suggested that the association processes are diffusion-controlled. The methodology is considered to be especially useful in the design and selection of excipients for a supramolecular system with preferred association and dissociation rate constants and understanding their mechanisms. It is believed that this new approach could be applicable to a wide range of ligand-receptor supramolecular systems and will surely help in understanding their complex mechanism.

  9. The measurement system of birefringence and Verdet constant of optical fiber

    NASA Astrophysics Data System (ADS)

    Huang, Yi; Chen, Li; Guo, Qiang; Pang, Fufei; Wen, Jianxiang; Shang, Yana; Wang, Tingyun

    2013-12-01

    The Faraday magneto-optical effect of optical fiber has many applications in monitoring magnetic field and electric current. When a linearly polarized light propagates in the direction of a magnetic field, the plane of polarization will rotate linearly proportional to the strength of the applied magnetic field, which following the relationship of θF =VBl. θF is the Faraday rotation angle, which is proportional to the magnetic flux density B and the Verdet constant V . However, when the optical fiber contains the effect of linear birefringence, the detection of Faraday rotation angle will depend on the line birefringence. In order to determine the Verdet constant of an optical fiber under a linear birefringence, the fiber birefringence needs to be accurately measured. In this work, a model is applied to analyze the polarization properties of an optical fiber by using the Jones matrix method. A measurement system based on the lock-in amplifier technology is designed to test the Verdet constant and the birefringence of optical fiber. The magnetic field is produced by a solenoid with a DC current. A tunable laser is intensity modulated with a motorized rotating chopper. The actuator supplies a signal as the phase-locked synchronization reference to the signal of the lock-in amplifier. The measurement accuracy is analyzed and the sensitivity of the system is optimized. In this measurement system, the Verdet constant of the SMF-28 fiber was measured to be 0.56±0.02 rad/T·m at 1550nm. This setup is well suitable for measuring the high signal-to-noise ratio (SNR) sensitivity for lock-in amplifier at a low magnetic field strength.

  10. 47 CFR 90.475 - Operation of internal transmitter control systems in specially equipped systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... systems involving fixed systems whose base stations are controlled by such systems may automatically access these base stations through the microwave or operational fixed systems from positions in the PSTN, so long as the base stations and mobile units meet the requirements of § 90.483 and if a separate...

  11. 47 CFR 90.763 - EA, Regional and nationwide system operations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Frequencies in the 220-222 MHz Band Policies Governing the Licensing and Use of Phase II Ea, Regional and Nationwide Systems § 90.763 EA, Regional and nationwide system operations. (a) A nationwide licensee... 47 Telecommunication 5 2011-10-01 2011-10-01 false EA, Regional and nationwide system operations...

  12. CODATA Fundamental Physical Constants

    National Institute of Standards and Technology Data Gateway

    SRD 121 NIST CODATA Fundamental Physical Constants (Web, free access)   This site, developed in the Physics Laboratory at NIST, addresses three topics: fundamental physical constants, the International System of Units (SI), which is the modern metric system, and expressing the uncertainty of measurement results.

  13. Transient Behavior of Lumped-Constant Systems for Sensing Gas Pressures

    NASA Technical Reports Server (NTRS)

    Delio, Gene J; Schwent, Glennon V; Cesaro, Richard S

    1949-01-01

    The development of theoretical equations describing the behavior of a lumped-constant pressure-sensing system under transient operation Is presented with experimental data that show agreement with the equations. A pressure-sensing system 'consisting of a tube terminating in a reservoir is investigated for the transient relation between a presSure disturbance at the open end of the tube and the pressure response in the reservoir. Design parameters are presented that can be adjusted to achieve a desired performance fran such a system when the system is considered as a transfer member of a control loop.

  14. Modeling and performance improvement of the constant power regulator systems in variable displacement axial piston pump.

    PubMed

    Park, Sung Hwan; Lee, Ji Min; Kim, Jong Shik

    2013-01-01

    An irregular performance of a mechanical-type constant power regulator is considered. In order to find the cause of an irregular discharge flow at the cut-off pressure area, modeling and numerical simulations are performed to observe dynamic behavior of internal parts of the constant power regulator system for a swashplate-type axial piston pump. The commercial numerical simulation software AMESim is applied to model the mechanical-type regulator with hydraulic pump and simulate the performance of it. The validity of the simulation model of the constant power regulator system is verified by comparing simulation results with experiments. In order to find the cause of the irregular performance of the mechanical-type constant power regulator system, the behavior of main components such as the spool, sleeve, and counterbalance piston is investigated using computer simulation. The shape modification of the counterbalance piston is proposed to improve the undesirable performance of the mechanical-type constant power regulator. The performance improvement is verified by computer simulation using AMESim software.

  15. Response of the human vestibulo-ocular reflex system to constant angular acceleration. I. Theoretical study.

    PubMed

    Boumans, L J; Rodenburg, M; Maas, A J

    1983-01-01

    The response of the human vestibulo-ocular reflex system to a constant angular acceleration is calculated using a second order model with an adaptation term. After first reaching a maximum the peracceleratory response declines. When the stimulus duration is long the decay is mainly governed by the adaptation time constant Ta, which enables to reliably estimate this time constant. In the postacceleratory period of constant velocity there is a reversal in response. The magnitude and the time course of the per- and postacceleratory response are calculated for various values of the cupular time constant T1, the adaptation time constant Ta, and the stimulus duration, thus enabling their influence to be assessed.

  16. Microscopic theoretical study of frequency dependent dielectric constant of heavy fermion systems

    NASA Astrophysics Data System (ADS)

    Shadangi, Keshab Chandra; Rout, G. C.

    2017-05-01

    The dielectric polarization and the dielectric constant plays a vital role in the deciding the properties of the Heavy Fermion Systems. In the present communication we consider the periodic Anderson's Model which consists of conduction electron kinetic energy, localized f-electron kinetic energy and the hybridization between the conduction and localized electrons, besides the Coulomb correlation energy. We calculate dielectric polarization which involves two particle Green's functions which are calculated by using Zubarev's Green's function technique. Using the equations of motion of the fermion electron operators. Finally, the temperature and frequency dependent dielectric constant is calculated from the dielectric polarization function. The charge susceptibility and dielectric constant are computed numerically for different physical parameters like the position (Ef) of the f-electron level with respect to fermi level, the strength of the hybridization (V) between the conduction and localized f-electrons, Coulomb correlation potential temperature and optical phonon wave vector (q). The results will be discussed in a reference to the experimental observations of the dielectric constants.

  17. Application of constant current, low voltage electrical stimulation systems to pig carcasses and its effects on pork quality.

    PubMed

    Channon, H A; Walker, P J; Kerr, M G; Baud, S R

    2003-12-01

    This study examined the effectiveness of a constant current, low voltage electrical stimulation system on improving pork quality when applied to pigs at 2 min post-exsanguination. A total of 48 female Duroc×Large White/Landrace pigs of 85-90 kg liveweight were randomly allocated immediately prior to slaughter to one of four constant current electrical stimulation treatments: control (no electrical stimulation), 50, 200 and 400 mA. Stimulation was applied to pig carcasses at 2 min post-exsanguination for 30 s. No differences (P>0.05) in WB shear force values, muscle lightness or PSE incidence of pork M. longissimus lumborum (LL) was found due to electrical stimulation treatment. Muscle pH of the LL muscle was lower (P<0.001) in carcasses in the 200 and 400 mA treatments compared to those from carcasses in both the 50 mA and control treatment groups, when measured at the various time points from 40 min to 8 h post-slaughter. Although carcasses stimulated with 200 and 400 mA had higher percentage drip loss (P<0.05) and purge (P<0.001), this was not found to impact WB shear force values, muscle lightness or PSE incidence.

  18. Modeling and Performance Improvement of the Constant Power Regulator Systems in Variable Displacement Axial Piston Pump

    PubMed Central

    Park, Sung Hwan; Lee, Ji Min; Kim, Jong Shik

    2013-01-01

    An irregular performance of a mechanical-type constant power regulator is considered. In order to find the cause of an irregular discharge flow at the cut-off pressure area, modeling and numerical simulations are performed to observe dynamic behavior of internal parts of the constant power regulator system for a swashplate-type axial piston pump. The commercial numerical simulation software AMESim is applied to model the mechanical-type regulator with hydraulic pump and simulate the performance of it. The validity of the simulation model of the constant power regulator system is verified by comparing simulation results with experiments. In order to find the cause of the irregular performance of the mechanical-type constant power regulator system, the behavior of main components such as the spool, sleeve, and counterbalance piston is investigated using computer simulation. The shape modification of the counterbalance piston is proposed to improve the undesirable performance of the mechanical-type constant power regulator. The performance improvement is verified by computer simulation using AMESim software. PMID:24282389

  19. Design of laser diode driver with constant current and temperature control system

    NASA Astrophysics Data System (ADS)

    Wang, Ming-cai; Yang, Kai-yong; Wang, Zhi-guo; Fan, Zhen-fang

    2017-10-01

    A laser Diode (LD) driver with constant current and temperature control system is designed according to the LD working characteristics. We deeply researched the protection circuit and temperature control circuit based on thermos-electric cooler(TEC) cooling circuit and PID algorithm. The driver could realize constant current output and achieve stable temperature control of LD. Real-time feedback control method was adopted in the temperature control system to make LD work on its best temperature point. The output power variety and output wavelength shift of LD caused by current and temperature instability were decreased. Furthermore, the driving current and working temperature is adjustable according to specific requirements. The experiment result showed that the developed LD driver meets the characteristics of LD.

  20. Theoretical Discussion of Electron Transport Rate Constant at TCNQ / Ge and TiO2 System

    NASA Astrophysics Data System (ADS)

    Al-agealy, Hadi J. M.; Alshafaay, B.; Hassooni, Mohsin A.; Ashwiekh, Ahmed M.; Sadoon, Abbas K.; Majeed, Raad H.; Ghadhban, Rawnaq Q.; Mahdi, Shatha H.

    2018-05-01

    We have been studying and estimation the electronic transport constant at TCNQ / Ge and Tio2 interface by means of tunneling potential (TP), transport energy reorientation (TER), driving transition energy DTE and coupling coefficient constant. A simple quantum model for the transition processes was adapted to estimation and analysis depending on the quantum state for donor state |α D > and acceptor stated |α A > and assuming continuum levels of the system. Evaluation results were performed for the surfaces of Ge and Tio2 as best as for multilayer TCNQ. The results show an electronic transfer feature for electronic TCNQ density of states and a semiconductor behavior. The electronic rate constant result for both systems shows a good tool to election system in applied devices. All these results indicate the

  1. Systemic and mucosal immunization with Candida albicans hsp90 elicits hsp90-specific humoral response in vaginal mucosa which is further enhanced during experimental vaginal candidiasis.

    PubMed

    Raska, Milan; Belakova, Jana; Horynova, Milada; Krupka, Michal; Novotny, Jiri; Sebestova, Martina; Weigl, Evzen

    2008-08-01

    The Candida albicans heat shock protein 90 kDa (hsp90-CA) is an important target for protective antibodies in disseminated candidiasis of experimental mice and humans. Hsp90-CA is present in the cell wall of Candida pseudohyphae or hyphae--typical pathogenic morphotypes in both mucosal and systemic Candida infections. However, the potential protective effects of hsp90-CA-specific antibodies in vaginal candidiasis has not yet been reported. In the present study we used various vaccine formulations (recombinant hsp90-CA protein and hsp90-CA-encoding DNA vaccine) and routes of administration (intradermal, intranasal, and intravenous) to induce both hsp90-CA-specific systemic and vaginal mucosa immune responses in experimental BALB/c mice. The results showed that intradermal recombinant hsp90-CA protein priming, followed by intranasal or intradermal recombinant hsp90-CA protein boosting induced significant increases in both serum and vaginal hsp90-CA-specific IgG and IgA antibodies compared to the control group, as well as enhanced hsp90-CA-specific splenocyte responses in vitro. In the intradermally boosted group, subsequent experimental vaginal Candida infection induced additional increases in the hsp90-CA specific IgG isotype, suggesting that Candida has the ability to induce a local hsp90-specific antibody (IgG) response during vulvovaginal candidiasis. Further work is required to elucidate the importance of immunity to highly conserved antigens during infection of the human female reproductive tract where a balance between immunity to and tolerance for commonly antigens such as hsp90 is necessary for the maintenance of fertility.

  2. Description and test results of a variable speed, constant frequency generating system

    NASA Astrophysics Data System (ADS)

    Brady, F. J.

    1985-12-01

    The variable-speed, constant frequency generating system developed for the Mod-0 wind turbine is presented. This report describes the system as it existed at the conclusion of the project. The cycloconverter control circuit is described including the addition of field-oriented control. The laboratory test and actual wind turbine test results are included.

  3. 40 CFR 86.527-90 - Test procedures, overview.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 86.527-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... constant volume (variable dilution) sampler. (d) Except in cases of component malfunction or failure, all... emissions measurements are made. For exhaust testing, this requires sampling and analysis of the dilution...

  4. 47 CFR 90.483 - Permissible methods and requirements of interconnecting private and public systems of...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... interconnecting private and public systems of communications. 90.483 Section 90.483 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES... private and public systems of communications. Interconnection may be accomplished by commercial mobile...

  5. 47 CFR 90.483 - Permissible methods and requirements of interconnecting private and public systems of...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... interconnecting private and public systems of communications. 90.483 Section 90.483 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES... private and public systems of communications. Interconnection may be accomplished by commercial mobile...

  6. 47 CFR 90.483 - Permissible methods and requirements of interconnecting private and public systems of...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... interconnecting private and public systems of communications. 90.483 Section 90.483 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES... private and public systems of communications. Interconnection may be accomplished by commercial mobile...

  7. 47 CFR 90.483 - Permissible methods and requirements of interconnecting private and public systems of...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... interconnecting private and public systems of communications. 90.483 Section 90.483 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES... private and public systems of communications. Interconnection may be accomplished by commercial mobile...

  8. Achieving NHAS 90/90/80 Objectives by 2020: An Interactive Tool Modeling Local HIV Prevalence Projections.

    PubMed

    Kelly, Jane M; Kelly, Scott D; Wortley, Pascale M; Drenzek, Cherie L

    2016-01-01

    Tools using local HIV data to help jurisdictions estimate future demand for medical and support services are needed. We present an interactive prevalence projection model using data obtainable from jurisdictional HIV surveillance and publically available data. Using viral load data from Georgia's enhanced HIV/AIDS Reporting System, state level death rates for people living with HIV and the general population, and published estimates for HIV transmission rates, we developed a model for projecting future HIV prevalence. Keeping death rates and HIV transmission rates for undiagnosed, in care/viral load >200, in care/viral load<200, and out of care (no viral load for 12 months) constant, we describe results from simulations with varying inputs projecting HIV incidence and prevalence from 2014 to 2024. In this model, maintaining Georgia's 2014 rates for diagnosis, transitions in care, viral suppression (VS), and mortality by sub-group through 2020, resulted in 85% diagnosed, 59% in care, and 44% VS among diagnosed (85%/58%/44%) with a total of 67 815 PLWH, 33 953 in care, and more than 1000 new cases per year by 2020. Neither doubling the diagnosis rate nor tripling rates of re-engaging out of care PLWH into care alone were adequate to reach 90/90/80 by 2020. We demonstrate a multicomponent scenario that achieved NHAS goals and resulted in 63 989 PLWH, 57 546 in care, and continued annual prevalence increase through 2024. Jurisdictions can use this HIV prevalence prediction tool, accessible at https://dph.georgia.gov/hiv-prevalence-projections to assess local capacity to meet future HIV care and social services needs. In this model, achieving 90/90/80 by 2020 in Georgia slowed but did not reverse increases in HIV prevalence, and the number of HIV-infected persons needing care and support services more than doubled. Improving the HIV care infrastructure is imperative.

  9. Converting Constant Volume, Multizone Air Handling Systems to Energy Efficient Variable Air Volume Multizone Systems

    DTIC Science & Technology

    2017-10-26

    30. Energy Information Agency Natural Gas Price Data ..................................................................................... 65 Figure...different market sectors (residential, commercial, and industrial). Figure 30. Energy Information Agency Natural Gas Price Data 7.2.3 AHU Size...1 FINAL REPORT Converting Constant Volume, Multizone Air Handling Systems to Energy Efficient Variable Air Volume Multizone

  10. The 90 90 90 strategy to end the HIV Pandemic by 2030: Can the supply chain handle it?

    PubMed Central

    Jamieson, David

    2016-01-01

    Introduction UNAIDS “90-90-90” strategy calls for 90% of HIV-infected individuals to be diagnosed by 2020, 90% of whom will be on anti-retroviral therapy (ART) and 90% of whom will achieve sustained virologic suppression. Reaching these targets by 2020 will reduce the HIV epidemic to a low-level endemic disease by 2030. However, moving the global response towards this universal test and treat model will pose huge challenges to public health systems in resource-limited settings, including global and local supply chain systems. These challenges are especially acute in Africa, which accounts for over 70% of the persons affected by HIV. Discussion From a supply chain perspective, each of the “90's” has possible complications and roadblocks towards realizing the promise envisioned by 90-90-90. For instance, ensuring that 90% of HIV-infected persons know their status will require a large increase in access to HIV tests compared with what is currently available. To ensure that there are enough anti-retrovirals available to treat the nearly 25 million people that will require them by 2020 represents a near doubling of the ARV supplied to treat the 13 million currently on treatment. Similarly, to monitor those on treatment means an unprecedented scale-up of viral load testing throughout Africa. Conclusions Larger issues include whether the capacity exists at the local level to handle these commodities when they arrive in the most severely affected countries, including considerations of the human resources and costs needed to make this strategy effective. We believe that such “real world” analysis of proposed strategies and policies is essential to ensure their most effective implementation. PMID:27370169

  11. The 90 90 90 strategy to end the HIV Pandemic by 2030: Can the supply chain handle it?

    PubMed

    Jamieson, David; Kellerman, Scott E

    2016-01-01

    UNAIDS "90-90-90" strategy calls for 90% of HIV-infected individuals to be diagnosed by 2020, 90% of whom will be on anti-retroviral therapy (ART) and 90% of whom will achieve sustained virologic suppression. Reaching these targets by 2020 will reduce the HIV epidemic to a low-level endemic disease by 2030. However, moving the global response towards this universal test and treat model will pose huge challenges to public health systems in resource-limited settings, including global and local supply chain systems. These challenges are especially acute in Africa, which accounts for over 70% of the persons affected by HIV. From a supply chain perspective, each of the "90's" has possible complications and roadblocks towards realizing the promise envisioned by 90-90-90. For instance, ensuring that 90% of HIV-infected persons know their status will require a large increase in access to HIV tests compared with what is currently available. To ensure that there are enough anti-retrovirals available to treat the nearly 25 million people that will require them by 2020 represents a near doubling of the ARV supplied to treat the 13 million currently on treatment. Similarly, to monitor those on treatment means an unprecedented scale-up of viral load testing throughout Africa. Larger issues include whether the capacity exists at the local level to handle these commodities when they arrive in the most severely affected countries, including considerations of the human resources and costs needed to make this strategy effective. We believe that such "real world" analysis of proposed strategies and policies is essential to ensure their most effective implementation.

  12. 40 CFR 160.90 - Animal and other test system care.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Testing Facilities Operation § 160.90 Animal and other test system care. (a) There shall be standard operating procedures for the housing, feeding, handling, and... terrestrial amphibians used in laboratory procedures that require manipulations and observations over an...

  13. 40 CFR 792.90 - Animal and other test system care.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Testing Facilities Operation § 792.90 Animal and other test system care. (a) There shall be standard operating procedures for the housing... adult terrestrial amphibians used in laboratory procedures that require manipulations and observations...

  14. 40 CFR 160.90 - Animal and other test system care.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Testing Facilities Operation § 160.90 Animal and other test system care. (a) There shall be standard operating procedures for the housing, feeding, handling, and... terrestrial amphibians used in laboratory procedures that require manipulations and observations over an...

  15. 40 CFR 160.90 - Animal and other test system care.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Testing Facilities Operation § 160.90 Animal and other test system care. (a) There shall be standard operating procedures for the housing, feeding, handling, and... terrestrial amphibians used in laboratory procedures that require manipulations and observations over an...

  16. 40 CFR 792.90 - Animal and other test system care.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Testing Facilities Operation § 792.90 Animal and other test system care. (a) There shall be standard operating procedures for the housing... adult terrestrial amphibians used in laboratory procedures that require manipulations and observations...

  17. 40 CFR 792.90 - Animal and other test system care.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Testing Facilities Operation § 792.90 Animal and other test system care. (a) There shall be standard operating procedures for the housing... adult terrestrial amphibians used in laboratory procedures that require manipulations and observations...

  18. 40 CFR 160.90 - Animal and other test system care.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Testing Facilities Operation § 160.90 Animal and other test system care. (a) There shall be standard operating procedures for the housing, feeding, handling, and... terrestrial amphibians used in laboratory procedures that require manipulations and observations over an...

  19. 40 CFR 792.90 - Animal and other test system care.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Testing Facilities Operation § 792.90 Animal and other test system care. (a) There shall be standard operating procedures for the housing... adult terrestrial amphibians used in laboratory procedures that require manipulations and observations...

  20. 40 CFR 792.90 - Animal and other test system care.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Testing Facilities Operation § 792.90 Animal and other test system care. (a) There shall be standard operating procedures for the housing... adult terrestrial amphibians used in laboratory procedures that require manipulations and observations...

  1. 40 CFR 160.90 - Animal and other test system care.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Testing Facilities Operation § 160.90 Animal and other test system care. (a) There shall be standard operating procedures for the housing, feeding, handling, and... terrestrial amphibians used in laboratory procedures that require manipulations and observations over an...

  2. 40 CFR 90.421 - Dilute gaseous exhaust sampling and analytical system description.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CFV sample probes and/or a heat exchanger or electronic flow compensation. Figure... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...

  3. 40 CFR 90.421 - Dilute gaseous exhaust sampling and analytical system description.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CFV sample probes and/or a heat exchanger or electronic flow compensation. Figure... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...

  4. 40 CFR 90.421 - Dilute gaseous exhaust sampling and analytical system description.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CFV sample probes and/or a heat exchanger or electronic flow compensation. Figure... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...

  5. Constant voltage electro-slag remelting control

    DOEpatents

    Schlienger, M.E.

    1996-10-22

    A system for controlling electrode gap in an electro-slag remelt furnace has a constant regulated voltage and an electrode which is fed into the slag pool at a constant rate. The impedance of the circuit through the slag pool is directly proportional to the gap distance. Because of the constant voltage, the system current changes are inversely proportional to changes in gap. This negative feedback causes the gap to remain stable. 1 fig.

  6. Constant voltage electro-slag remelting control

    DOEpatents

    Schlienger, Max E.

    1996-01-01

    A system for controlling electrode gap in an electro-slag remelt furnace has a constant regulated voltage and an eletrode which is fed into the slag pool at a constant rate. The impedance of the circuit through the slag pool is directly proportional to the gap distance. Because of the constant voltage, the system current changes are inversely proportional to changes in gap. This negative feedback causes the gap to remain stable.

  7. Construction of exact constants of motion and effective models for many-body localized systems

    NASA Astrophysics Data System (ADS)

    Goihl, M.; Gluza, M.; Krumnow, C.; Eisert, J.

    2018-04-01

    One of the defining features of many-body localization is the presence of many quasilocal conserved quantities. These constants of motion constitute a cornerstone to an intuitive understanding of much of the phenomenology of many-body localized systems arising from effective Hamiltonians. They may be seen as local magnetization operators smeared out by a quasilocal unitary. However, accurately identifying such constants of motion remains a challenging problem. Current numerical constructions often capture the conserved operators only approximately, thus restricting a conclusive understanding of many-body localization. In this work, we use methods from the theory of quantum many-body systems out of equilibrium to establish an alternative approach for finding a complete set of exact constants of motion which are in addition guaranteed to represent Pauli-z operators. By this we are able to construct and investigate the proposed effective Hamiltonian using exact diagonalization. Hence, our work provides an important tool expected to further boost inquiries into the breakdown of transport due to quenched disorder.

  8. Shock tube measurements of growth constants in the branched chain formaldehyde-carbon monoxide-oxygen system

    NASA Technical Reports Server (NTRS)

    Brabbs, T. A.; Brokaw, R. S.

    1982-01-01

    Exponential free radical growth constants were measured for formaldehyde carbon monoxide-oxygen systems by monitoring the growth of oxygen atom concentration as manifested by CO flame band emission. Data were obtained over the temperature range of 1200 to 2000 K. The data were analyzed using a formaldehyde oxidation mechanism involving 12 elementary reaction steps. The computed growth constants are roughly in accord with experimental values, but are much more temperature dependent. The data was also analyzed assuming formaldehyde is rapidly decomposed to carbon monoxide and hydrogen. Growth constants computed for the resulting carbon monoxide hydrogen oxygen mixtures have a temperature dependence similar to experiments; however, for most mixtures, the computed growth constants were larger than experimental values.

  9. Construction of Lines of Constant Density and Constant Refractive Index for Ternary Liquid Mixtures.

    ERIC Educational Resources Information Center

    Tasic, Aleksandar Z.; Djordjevic, Bojan D.

    1983-01-01

    Demonstrates construction of density constant and refractive index constant lines in triangular coordinate system on basis of systematic experimental determinations of density and refractive index for both homogeneous (single-phase) ternary liquid mixtures (of known composition) and the corresponding binary compositions. Background information,…

  10. A full set of langatate high-temperature acoustic wave constants: elastic, piezoelectric, dielectric constants up to 900°C.

    PubMed

    Davulis, Peter M; da Cunha, Mauricio Pereira

    2013-04-01

    A full set of langatate (LGT) elastic, dielectric, and piezoelectric constants with their respective temperature coefficients up to 900°C is presented, and the relevance of the dielectric and piezoelectric constants and temperature coefficients are discussed with respect to predicted and measured high-temperature SAW propagation properties. The set of constants allows for high-temperature acoustic wave (AW) propagation studies and device design. The dielectric constants and polarization and conductive losses were extracted by impedance spectroscopy of parallel-plate capacitors. The measured dielectric constants at high temperatures were combined with previously measured LGT expansion coefficients and used to determine the elastic and piezoelectric constants using resonant ultrasound spectroscopy (RUS) measurements at temperatures up to 900°C. The extracted LGT piezoelectric constants and temperature coefficients show that e11 and e14 change by up to 62% and 77%, respectively, for the entire 25°C to 900°C range when compared with room-temperature values. The LGT high-temperature constants and temperature coefficients were verified by comparing measured and predicted phase velocities (vp) and temperature coefficients of delay (TCD) of SAW delay lines fabricated along 6 orientations in the LGT plane (90°, 23°, Ψ) up to 900°C. For the 6 tested orientations, the predicted SAW vp agree within 0.2% of the measured vp on average and the calculated TCD is within 9.6 ppm/°C of the measured value on average over the temperature range of 25°C to 900°C. By including the temperature dependence of both dielectric and piezoelectric constants, the average discrepancies between predicted and measured SAW properties were reduced, on average: 77% for vp, 13% for TCD, and 63% for the turn-over temperatures analyzed.

  11. Variable energy constant current accelerator structure

    DOEpatents

    Anderson, O.A.

    1988-07-13

    A variable energy, constant current ion beam accelerator structure is disclosed comprising an ion source capable of providing the desired ions, a pre-accelerator for establishing an initial energy level, a matching/pumping module having means for focusing means for maintaining the beam current, and at least one main accelerator module for continuing beam focus, with means capable of variably imparting acceleration to the beam so that a constant beam output current is maintained independent of the variable output energy. In a preferred embodiment, quadrupole electrodes are provided in both the matching/pumping module and the one or more accelerator modules, and are formed using four opposing cylinder electrodes which extend parallel to the beam axis and are spaced around the beam at 90/degree/ intervals with opposing electrodes maintained at the same potential. 12 figs., 3 tabs.

  12. Ballast system for maintaining constant pressure in a glove box

    NASA Technical Reports Server (NTRS)

    Shlichta, Paul J. (Inventor)

    1990-01-01

    A ballast system for a glove box including a fixed platform on which is mounted an inflatable bag on top of which resides a cover and a weight. The variable gas volume of the inflatable bag communicates with that of the glove box via a valved tube. The weight and gas volume are selected to maintain a relatively constant pressure in the glove box despite variations in the glove box volume while avoiding the use of complicated valving apparatus.

  13. Adjoint-based constant-mass partial derivatives

    DOE PAGES

    Favorite, Jeffrey A.

    2017-09-01

    In transport theory, adjoint-based partial derivatives with respect to mass density are constant-volume derivatives. Likewise, adjoint-based partial derivatives with respect to surface locations (i.e., internal interface locations and the outer system boundary) are constant-density derivatives. This study derives the constant-mass partial derivative of a response with respect to an internal interface location or the outer system boundary and the constant-mass partial derivative of a response with respect to the mass density of a region. Numerical results are given for a multiregion two-dimensional (r-z) cylinder for three very different responses: the uncollided gamma-ray flux at an external detector point, k effmore » of the system, and the total neutron leakage. Finally, results from the derived formulas compare extremely well with direct perturbation calculations.« less

  14. Overexpression of GmHsp90s, a Heat Shock Protein 90 (Hsp90) Gene Family Cloning from Soybean, Decrease Damage of Abiotic Stresses in Arabidopsis thaliana

    PubMed Central

    Xue, Dong; Zhao, Jinming; Gai, Junyi; Guo, Na; Xing, Han

    2013-01-01

    Hsp90 is one of the most conserved and abundant molecular chaperones and is an essential component of the protective stress response; however, its roles in abiotic stress responses in soybean (Glycine max) remain obscure. Here, 12 GmHsp90 genes from soybean were identified and found to be expressed and to function differentially under abiotic stresses. The 12 GmHsp90 genes were isolated and named GmHsp90A1–GmHsp90A6, GmHsp90B1, GmHsp90B2, GmHsp90C1.1, GmHsp90C1.2, GmHsp90C2.1 and GmHsp90C2.2 based on their characteristics and high homology to other Hsp90s according to a new nomenclature system. Quantitative real-time PCR expression data revealed that all the genes exhibited higher transcript levels in leaves and could be strongly induced under heat, osmotic and salt stress but not cold stress. Overexpression of five typical genes (GmHsp90A2, GmHsp90A4, GmHsp90B1, GmHsp90C1.1 and GmHsp90C2.1) in Arabidopsis thaliana provided useful evidences that GmHsp90 genes can decrease damage of abiotic stresses. In addition, an abnormal accumulation of proline was detected in some transgenic Arabidopsis plants suggested overexpressing GmHsp90s may affect the synthesis and response system of proline. Our work represents a systematic determination of soybean genes encoding Hsp90s, and provides useful evidence that GmHsp90 genes function differently in response to abiotic stresses and may affect the synthesis and response system of proline. PMID:23936107

  15. Synthesis of Optimal Constant-Gain Positive-Real Controllers for Passive Systems

    NASA Technical Reports Server (NTRS)

    Mao, Y.; Kelkar, A. G.; Joshi, S. M.

    1999-01-01

    This paper presents synthesis methods for the design of constant-gain positive real controllers for passive systems. The results presented in this paper, in conjunction with the previous work by the authors on passification of non-passive systems, offer a useful synthesis tool for the design of passivity-based robust controllers for non-passive systems as well. Two synthesis approaches are given for minimizing an LQ-type performance index, resulting in optimal controller gains. Two separate algorithms, one for each of these approaches, are given. The synthesis techniques are demonstrated using two numerical examples: control of a flexible structure and longitudinal control of a fighter aircraft.

  16. Constant voltage and constant current control implementation for electric vehicles (evs) wireless charger

    NASA Astrophysics Data System (ADS)

    Tampubolon, Marojahan; Pamungkas, Laskar; Hsieh, Yao Ching; Chiu, Huang Jen

    2018-04-01

    This paper presents the implementation of Constant Voltage (CV) and Constant Current (CC) control for a wireless charger system. A battery charging system needs these control modes to ensure the safety of the battery and the effectiveness of the charging system. Here, the wireless charger system does not employ any post-regulator stage to control the output voltage and output current of the charger. But, it uses a variable frequency control incorporated with a conventional PI control. As a result, the size and the weight of the system are reduced. This paper discusses the brief review of the SS-WPT, control strategy and implementation of the CV and CC control. Experimental hardware with 2kW output power has been performed and tested. The results show that the proposed CV and CC control method works well with the system.

  17. Phosphate adsorption on hematite, kaolinite, and kaolinite-hematite (k-h) systems as described by a constant capacitance model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ioannou, A.; Dimirkou, A.

    1997-08-01

    The constant capacitance model was used to describe phosphate adsorption on hematite, kaolinite, and a kaolinite-hematite system (k-h). The model assumes a ligand exchange mechanism and considers the charge on both adsorbate and adsorbent. The model is shown to provide a quantitative description of phosphate adsorption on these, including the effect of varying pH values. The computer program Ma-Za 2, a program that fits equilibrium constants to experimental data using an optimization technique, was used to obtain optimal values for the anion surface complexation constants on hematite, kaolinite, and a kaolinite-hematite system, while the PC program Ma-Za 1 in Q-Basicmore » language was used for the application of the constant capacitance model. The model represented adsorption of phosphate anions well over the entire pH range studied (3.8--9.0). The main advantage of the model is its ability to represent changes in anion adsorption occurring with changes in pH. Extension of the model to describe phosphate adsorption in a mixed system, such as the kaolinite-hematite system, using the surface protonation-dissociation constant of hematite was qualitatively successful. In mixed system the model reproduced the shape of the adsorption isotherms well over the pH range 3.8--9.0. However, phosphate adsorption was overestimated. The hematite and the kaolinite-hematite system were synthesized and identified by X-ray, NMR, and FT-IR spectroscopy.« less

  18. Ballast system for maintaining constant pressure in a glove box

    NASA Technical Reports Server (NTRS)

    Shlichta, Paul J. (Inventor)

    1989-01-01

    A ballast system is disclosed for a glove box including a fixed platform on which is mounted an inflatable bag on top of which resides a cover and a weight. The variable gas volume of the inflatable bag communicates with that of the glove box via a valved tube. The weight and the gas volume are selected to maintain a relatively constant pressure in the glove box despite variations in the glove box volume while avoiding the use of complicated valving apparatus.

  19. Ballast system for maintaining constant pressure in a glove box

    NASA Astrophysics Data System (ADS)

    Shlichta, Paul J.

    1989-09-01

    A ballast system is disclosed for a glove box including a fixed platform on which is mounted an inflatable bag on top of which resides a cover and a weight. The variable gas volume of the inflatable bag communicates with that of the glove box via a valved tube. The weight and the gas volume are selected to maintain a relatively constant pressure in the glove box despite variations in the glove box volume while avoiding the use of complicated valving apparatus.

  20. Effective-range parameters and vertex constants for Λ-nuclear systems

    NASA Astrophysics Data System (ADS)

    Rakityansky, S. A.; Gopane, I. M.

    For a wide range of the core-nuclei (6 ≤ A ≤ 207), the scattering lengths, effective radii, and the other effective-range parameters (up to the order ˜ k8) for the angular momentum ℓ = 0, 1, 2 are calculated within a two-body ΛA-model. For the same hypernuclear systems, the S-matrix residues as well as the corresponding Nuclear-Vertex and Asymptotic-Normalization constants (NVC’s and ANC’s) for the bound states are also found.

  1. Conformational Activation of Argonaute by Distinct yet Coordinated Actions of the Hsp70 and Hsp90 Chaperone Systems.

    PubMed

    Tsuboyama, Kotaro; Tadakuma, Hisashi; Tomari, Yukihide

    2018-05-17

    Loading of small RNAs into Argonaute, the core protein in RNA silencing, requires the Hsp70/Hsp90 chaperone machinery. This machinery also activates many other clients, including steroid hormone receptors and kinases, but how their structures change during chaperone-dependent activation remains unclear. Here, we utilized single-molecule Förster resonance energy transfer (smFRET) to probe the conformational changes of Drosophila Ago2 mediated by the chaperone machinery. We found that empty Ago2 exists in various closed conformations. The Hsp70 system (Hsp40 and Hsp70) and the Hsp90 system (Hop, Hsp90, and p23) together render Ago2 into an open, active form. The Hsp70 system, but not the Hsp90 system alone, is sufficient for Ago2 to partially populate the open form. Instead, the Hsp90 system is required to extend the dwell time of Ago2 in the open state, which must be transiently primed by the Hsp70 system. Our data uncover distinct and coordinated actions of the chaperone machinery, where the Hsp70 system expands the structural ensembles of Ago2 and the Hsp90 system captures and stabilizes the active form. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Repeated action of a constant magnetic field on the blood coagulation system in artificially produced anemia

    NASA Technical Reports Server (NTRS)

    Zabrodina, L. V.

    1974-01-01

    Changes are discussed in the coagulatory system of the blood in rabbits under the influence of a constant magnetic field of an intensity of 2500 oersteds against the background of artificially induced anemia. Reversibility of the changes produced and the presence of the adaptational effect are noted. Taking all this into consideration, the changes involving the coagulatory system of the blood which arise under the influence of a constant magnetic field may be considered to have a nerve-reflex nature.

  3. Late-time behaviour of the Einstein–Boltzmann system with a positive cosmological constant

    NASA Astrophysics Data System (ADS)

    Lee, Ho; Nungesser, Ernesto

    2018-01-01

    In this paper we study the Einstein–Boltzmann system for Israel particles with a positive cosmological constant. We consider spatially homogeneous solutions of all Bianchi types except type IX and obtain future global existence and the asymptotic behaviour of solutions to the Einstein–Boltzmann system. The result shows that the solutions converge to the de Sitter solution at late times.

  4. Design of high-linear CMOS circuit using a constant transconductance method for gamma-ray spectroscopy system

    NASA Astrophysics Data System (ADS)

    Jung, I. I.; Lee, J. H.; Lee, C. S.; Choi, Y.-W.

    2011-02-01

    We propose a novel circuit to be applied to the front-end integrated circuits of gamma-ray spectroscopy systems. Our circuit is designed as a type of current conveyor (ICON) employing a constant- gm (transconductance) method which can significantly improve the linearity in the amplified signals by using a large time constant and the time-invariant characteristics of an amplifier. The constant- gm method is obtained by a feedback control which keeps the transconductance of the input transistor constant. To verify the performance of the propose circuit, the time constant variations for the channel resistances are simulated with the TSMC 0.18 μm transistor parameters using HSPICE, and then compared with those of a conventional ICON. As a result, the proposed ICON shows only 0.02% output linearity variation and 0.19% time constant variation for the input amplitude up to 100 mV. These are significantly small values compared to a conventional ICON's 1.39% and 19.43%, respectively, for the same conditions.

  5. 40 CFR 90.421 - Dilute gaseous exhaust sampling and analytical system description.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... filter and HFID. Determine these gas temperatures by a temperature sensor located immediately upstream of... analytical system description. (a) General. The exhaust gas sampling system described in this section is...-CVS must conform to all of the requirements listed for the exhaust gas PDP-CVS in § 90.420 of this...

  6. 40 CFR 90.421 - Dilute gaseous exhaust sampling and analytical system description.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... filter and HFID. Determine these gas temperatures by a temperature sensor located immediately upstream of... analytical system description. (a) General. The exhaust gas sampling system described in this section is...-CVS must conform to all of the requirements listed for the exhaust gas PDP-CVS in § 90.420 of this...

  7. Lie symmetries of systems of second-order linear ordinary differential equations with constant coefficients.

    PubMed

    Boyko, Vyacheslav M; Popovych, Roman O; Shapoval, Nataliya M

    2013-01-01

    Lie symmetries of systems of second-order linear ordinary differential equations with constant coefficients are exhaustively described over both the complex and real fields. The exact lower and upper bounds for the dimensions of the maximal Lie invariance algebras possessed by such systems are obtained using an effective algebraic approach.

  8. 47 CFR 90.359 - Field strength limits for EA-licensed LMS systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Field strength limits for EA-licensed LMS... § 90.359 Field strength limits for EA-licensed LMS systems. EA-licensed multilateration systems shall limit the field strength of signals transmitted from their base stations to 47 dBuV/m at their EA...

  9. Elastic constants and pressure derivative of elastic constants of Si1-xGex solid solution

    NASA Astrophysics Data System (ADS)

    Jivani, A. R.; Baria, J. K.; Vyas, P. S.; Jani, A. R.

    2013-02-01

    Elastic properties of Si1-xGex solid solution with arbitrary (atomic) concentration (x) are studied using the pseudo-alloy atom model based on the pseudopotential theory and on the higher-order perturbation scheme with the application of our own proposed model potential. We have used local-field correction function proposed by Sarkar et al to study Si-Ge system. The Elastic constants and pressure derivatives of elastic constants of the solid solution is investigated with different concentration x of Ge. It is found in the present study that the calculated numerical values of the aforesaid physical properties of Si-Ge system are function of x. The elastic constants (C11, C12 and C44) decrease linearly with increase in concentration x and pressure derivative of elastic constants (C11, C12 and C44) increase with the concentration x of Ge. This study provides better set of theoretical results for such solid solution for further comparison either with theoretical or experimental results.

  10. Lie symmetries of systems of second-order linear ordinary differential equations with constant coefficients

    PubMed Central

    Boyko, Vyacheslav M.; Popovych, Roman O.; Shapoval, Nataliya M.

    2013-01-01

    Lie symmetries of systems of second-order linear ordinary differential equations with constant coefficients are exhaustively described over both the complex and real fields. The exact lower and upper bounds for the dimensions of the maximal Lie invariance algebras possessed by such systems are obtained using an effective algebraic approach. PMID:23564972

  11. Elongational flow of polymer melts at constant strain rate, constant stress and constant force

    NASA Astrophysics Data System (ADS)

    Wagner, Manfred H.; Rolón-Garrido, Víctor H.

    2013-04-01

    Characterization of polymer melts in elongational flow is typically performed at constant elongational rate or rarely at constant tensile stress conditions. One of the disadvantages of these deformation modes is that they are hampered by the onset of "necking" instabilities according to the Considère criterion. Experiments at constant tensile force have been performed even more rarely, in spite of the fact that this deformation mode is free from necking instabilities and is of considerable industrial relevance as it is the correct analogue of steady fiber spinning. It is the objective of the present contribution to present for the first time a full experimental characterization of a long-chain branched polyethylene melt in elongational flow. Experiments were performed at constant elongation rate, constant tensile stress and constant tensile force by use of a Sentmanat Extensional Rheometer (SER) in combination with an Anton Paar MCR301 rotational rheometer. The accessible experimental window and experimental limitations are discussed. The experimental data are modelled by using the Wagner I model. Predictions of the steady-start elongational viscosity in constant strain rate and creep experiments are found to be identical, albeit only by extrapolation of the experimental data to Hencky strains of the order of 6. For constant stress experiments, a minimum in the strain rate and a corresponding maximum in the elongational viscosity is found at a Hencky strain of the order of 3, which, although larger than the steady-state value, follows roughly the general trend of the steady-state elongational viscosity. The constitutive analysis also reveals that constant tensile force experiments indicate a larger strain hardening potential than seen in constant elongation rate or constant tensile stress experiments. This may be indicative of the effect of necking under constant elongation rate or constant tensile stress conditions according to the Considère criterion.

  12. Hyperfine Structure Constants of Energetically High-lying Levels of Odd Parity of Atomic Vanadium

    NASA Astrophysics Data System (ADS)

    Güzelçimen, F.; Yapıcı, B.; Demir, G.; Er, A.; Öztürk, I. K.; Başar, Gö.; Kröger, S.; Tamanis, M.; Ferber, R.; Docenko, D.; Başar, Gü.

    2014-09-01

    High-resolution Fourier transform spectra of a vanadium-argon plasma have been recorded in the wavelength range of 365-670 nm (15,000-27,400 cm-1). Optical bandpass filters were used in the experimental setup to enhance the sensitivity of the Fourier transform spectrometer. In total, 138 atomic vanadium spectral lines showing resolved or partially resolved hyperfine structure have been analyzed to determine the magnetic dipole hyperfine structure constants A of the involved energy levels. One of the investigated lines has not been previously classified. As a result, the magnetic dipole hyperfine structure constants A for 90 energy levels are presented: 35 of them belong to the configuration 3d 34s4p and 55 to the configuration 3d 44p. Of these 90 constants, 67 have been determined for the first time, with 23 corresponding to the configuration 3d 34s4p and 44 to 3d 44p.

  13. (In)validity of the constant field and constant currents assumptions in theories of ion transport.

    PubMed Central

    Syganow, A; von Kitzing, E

    1999-01-01

    Constant electric fields and constant ion currents are often considered in theories of ion transport. Therefore, it is important to understand the validity of these helpful concepts. The constant field assumption requires that the charge density of permeant ions and flexible polar groups is virtually voltage independent. We present analytic relations that indicate the conditions under which the constant field approximation applies. Barrier models are frequently fitted to experimental current-voltage curves to describe ion transport. These models are based on three fundamental characteristics: a constant electric field, negligible concerted motions of ions inside the channel (an ion can enter only an empty site), and concentration-independent energy profiles. An analysis of those fundamental assumptions of barrier models shows that those approximations require large barriers because the electrostatic interaction is strong and has a long range. In the constant currents assumption, the current of each permeating ion species is considered to be constant throughout the channel; thus ion pairing is explicitly ignored. In inhomogeneous steady-state systems, the association rate constant determines the strength of ion pairing. Among permeable ions, however, the ion association rate constants are not small, according to modern diffusion-limited reaction rate theories. A mathematical formulation of a constant currents condition indicates that ion pairing very likely has an effect but does not dominate ion transport. PMID:9929480

  14. 47 CFR 90.473 - Operation of internal transmitter control systems through licensed fixed control points.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Operation of internal transmitter control systems through licensed fixed control points. 90.473 Section 90.473 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control...

  15. 47 CFR 90.473 - Operation of internal transmitter control systems through licensed fixed control points.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Operation of internal transmitter control systems through licensed fixed control points. 90.473 Section 90.473 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control...

  16. 47 CFR 90.473 - Operation of internal transmitter control systems through licensed fixed control points.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Operation of internal transmitter control systems through licensed fixed control points. 90.473 Section 90.473 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control...

  17. 47 CFR 90.473 - Operation of internal transmitter control systems through licensed fixed control points.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Operation of internal transmitter control systems through licensed fixed control points. 90.473 Section 90.473 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control...

  18. 47 CFR 90.473 - Operation of internal transmitter control systems through licensed fixed control points.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Operation of internal transmitter control systems through licensed fixed control points. 90.473 Section 90.473 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control...

  19. Structure and properties of barium tin boro-phosphate glass systems with very low photoelastic constant

    NASA Astrophysics Data System (ADS)

    Itadani, M.; Tricot, G.; Doumert, B.; Takebe, H.; Saitoh, A.

    2017-08-01

    Glasses in the BaO-SnO-P2O5-B2O3 system were prepared and evaluated in order to formulate preform glasses suitable for the fabrication of fiber cores with a very low photoelastic constant. A first glass system (I: xBaO-(60-x)SnO-40P2O5) was designed with a constant P2O5 content and various BaO contents (0-40 mol. %). Introduction of 3 mol. % of B2O3 to enhance the glass stability leads to the second glass system (II: x'BaO-(57-x')SnO-40P2O5-3B2O3) with 33-38 mol. % BaO. The structure of both systems was investigated by 1D/2D magic-angle spinning nuclear magnetic resonance, Raman, and Fourier transform infrared spectroscopic techniques. 31P NMR showed the presence of Q2 and Q1 units in the first system and correlation 11B/31P NMR indicated that boron enters into the network as B(OP)4 structural units. The photoelastic constant was determined and the stability of the best formulations as well as their refractive index dispersion was established. The drawing temperature and isothermal heating time (without crystal precipitation) parameters were also accurately measured by using experimental time-temperature-transition. Considering that the refractive indices of the core and the cladding materials must match, detailed core and cladding compositions for a fiber enabling single-mode waveguide transmission were proposed.

  20. Detection of bremsstrahlung radiation of 90Sr-90Y for emergency lung counting.

    PubMed

    Ho, A; Hakmana Witharana, S S; Jonkmans, G; Li, L; Surette, R A; Dubeau, J; Dai, X

    2012-09-01

    This study explores the possibility of developing a field-deployable (90)Sr detector for rapid lung counting in emergency situations. The detection of beta-emitters (90)Sr and its daughter (90)Y inside the human lung via bremsstrahlung radiation was performed using a 3″ × 3″ NaI(Tl) crystal detector and a polyethylene-encapsulated source to emulate human lung tissue. The simulation results show that this method is a viable technique for detecting (90)Sr with a minimum detectable activity (MDA) of 1.07 × 10(4) Bq, using a realistic dual-shielded detector system in a 0.25-µGy h(-1) background field for a 100-s scan. The MDA is sufficiently sensitive to meet the requirement for emergency lung counting of Type S (90)Sr intake. The experimental data were verified using Monte Carlo calculations, including an estimate for internal bremsstrahlung, and an optimisation of the detector geometry was performed. Optimisations in background reduction techniques and in the electronic acquisition systems are suggested.

  1. Constant potential pulse polarography

    USGS Publications Warehouse

    Christie, J.H.; Jackson, L.L.; Osteryoung, R.A.

    1976-01-01

    The new technique of constant potential pulse polarography, In which all pulses are to be the same potential, is presented theoretically and evaluated experimentally. The response obtained is in the form of a faradaic current wave superimposed on a constant capacitative component. Results obtained with a computer-controlled system exhibit a capillary response current similar to that observed In normal pulse polarography. Calibration curves for Pb obtained using a modified commercial pulse polarographic instrument are in good accord with theoretical predictions.

  2. Constant current loop impedance measuring system that is immune to the effects of parasitic impedances

    NASA Technical Reports Server (NTRS)

    Anderson, Karl F. (Inventor)

    1994-01-01

    A constant current loop measuring system is provided for measuring a characteristic of an environment. The system comprises a first impedance positionable in the environment, a second impedance coupled in series with said first impedance and a parasitic impedance electrically coupled to the first and second impedances. A current generating device, electrically coupled in series with the first and second impedances, provides a constant current through the first and second impedances to produce first and second voltages across the first and second impedances, respectively, and a parasitic voltage across the parasitic impedance. A high impedance voltage measuring device measures a voltage difference between the first and second voltages independent of the parasitic voltage to produce a characteristic voltage representative of the characteristic of the environment.

  3. Biodegradation testing of chemicals with high Henry's constants - Separating mass and effective concentration reveals higher rate constants.

    PubMed

    Birch, Heidi; Andersen, Henrik R; Comber, Mike; Mayer, Philipp

    2017-05-01

    During simulation-type biodegradation tests, volatile chemicals will continuously partition between water phase and headspace. This study addressed how (1) this partitioning affects test results and (2) can be accounted for by combining equilibrium partition and dynamic biodegradation models. An aqueous mixture of 9 (semi)volatile chemicals was first generated using passive dosing and then diluted with environmental surface water producing concentrations in the ng/L to μg/L range. After incubation for 2 h to 4 weeks, automated Headspace Solid Phase Microextraction (HS-SPME) was applied directly on the test systems to measure substrate depletion by biodegradation relatively to abiotic controls. HS-SPME was also applied to determine air to water partitioning ratios. Biodegradation rate constants relating to the chemical in the water phase, k water , were generally a factor 1 to 11 times higher than biodegradation rate constants relating to the total mass of chemical in the test system, k system , with one exceptional factor of 72 times for a long chain alkane. True water phase degradation rate constants were found (i) more appropriate for risk assessment than test system rate constants, (ii) to facilitate extrapolation to other air-water systems and (iii) to be better defined input parameters for aquatic exposure and fate models. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. 46 CFR 147.90 - Refrigerants.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Refrigerants. 147.90 Section 147.90 Shipping COAST GUARD... Special Requirements for Particular Materials § 147.90 Refrigerants. (a) Only refrigerants listed in ANSI/ASHRAE 34-78 may be carried as ships' stores. (b) Refrigerants contained in a vessel's operating system...

  5. 46 CFR 147.90 - Refrigerants.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Refrigerants. 147.90 Section 147.90 Shipping COAST GUARD... Special Requirements for Particular Materials § 147.90 Refrigerants. (a) Only refrigerants listed in ANSI/ASHRAE 34-78 may be carried as ships' stores. (b) Refrigerants contained in a vessel's operating system...

  6. Application of TREECS Modeling System to Strontium-90 for Borschi Watershed near Chernobyl, Ukraine.

    PubMed

    Johnson, Billy E; Dortch, Mark S

    2014-05-01

    The Training Range Environmental Evaluation and Characterization System (TREECS™) (http://el.erdc.usace.army.mil/treecs/) is being developed by the U.S. Army Engineer Research and Development Center (ERDC) for the U.S. Army to forecast the fate of munitions constituents (MC) (such as high explosives (HE) and metals) found on firing/training ranges, as well as those subsequently transported to surface water and groundwater. The overall purpose of TREECS™ is to provide environmental specialists with tools to assess the potential for MC migration into surface water and groundwater systems and to assess range management strategies to ensure protection of human health and the environment. The multimedia fate/transport models within TREECS™ are mathematical models of reduced form (e.g., reduced dimensionality) that allow rapid application with less input data requirements compared with more complicated models. Although TREECS™ was developed for the fate of MC from military ranges, it has general applicability to many other situations requiring prediction of contaminant (including radionuclide) fate in multi-media environmental systems. TREECS™ was applied to the Borschi watershed near the Chernobyl Nuclear Power Plant, Ukraine. At this site, TREECS™ demonstrated its use as a modeling tool to predict the fate of strontium 90 ((90)Sr). The most sensitive and uncertain input for this application was the soil-water partitioning distribution coefficient (Kd) for (90)Sr. The TREECS™ soil model provided reasonable estimates of the surface water export flux of (90)Sr from the Borschi watershed when using a Kd for (90)Sr of 200 L/kg. The computed export for the year 2000 was 0.18% of the watershed inventory of (90)Sr compared to the estimated export flux of 0.14% based on field data collected during 1999-2001. The model indicated that assumptions regarding the form of the inventory, whether dissolved or in solid phase form, did not appreciably affect export rates

  7. Limiting vibration in systems with constant amplitude actuators through command preshaping. M.S Thesis - MIT

    NASA Technical Reports Server (NTRS)

    Rogers, Keith Eric

    1994-01-01

    The basic concepts of command preshaping were taken and adapted to the framework of systems with constant amplitude (on-off) actuators. In this context, pulse sequences were developed which help to attenuate vibration in flexible systems with high robustness to errors in frequency identification. Sequences containing impulses of different magnitudes were approximated by sequences containing pulses of different durations. The effects of variation in pulse width on this approximation were examined. Sequences capable of minimizing loads induced in flexible systems during execution of commands were also investigated. The usefulness of these techniques in real-world situations was verified by application to a high fidelity simulation of the space shuttle. Results showed that constant amplitude preshaping techniques offer a substantial improvement in vibration reduction over both the standard and upgraded shuttle control methods and may be mission enabling for use of the shuttle with extremely massive payloads.

  8. Relativistic problems on astronomical constants.

    NASA Astrophysics Data System (ADS)

    Tao, Jinhe; Huang, Tianyi

    1999-06-01

    The fact that modern astronomical observational technique has made rapid progress and the 1PN approximation of general relativity has been extensively applied in celestial mechanics and astrometry, makes it is necessary to investigate and examine the system of astronomical constants carefully and rigorously in the relativistic framework. The mass of a celestial body in the solar system should be defined as its BD mass that changes relatively in an amount less than 10-19 and could be considered as a constant. The equations satisfied by the gravitational potentials are not Poisson equations anymore but depend on the choice of the coordinate gauge. Therefore the gravitational potentials cannot be expanded in the traditional harmonics. It is neccessary to choose the coordinate gauge and take BD multipole moments as astronomical constants. The obliquity of the ecliptic has been determined in high precision and it would be neccessary to give a conventional definition of the 1PN ecliptic. A relativistic definition of the geoid is important and left to be discussed. The astronomical constants that relate the units of time and length have been clearly defined but need to be clarified to avoid their misuse.

  9. Temperature dependence of (+)-catechin pyran ring proton coupling constants as measured by NMR and modeled using GMMX search methodology

    Treesearch

    Fred L. Tobiason; Stephen S. Kelley; M. Mark Midland; Richard W. Hemingway

    1997-01-01

    The pyran ring proton coupling constants for (+)-catechin have been experimentally determined in deuterated methanol over a temperature range of 213 K to 313 K. The experimental coupling constants were simulated to 0.04 Hz on the average at a 90 percent confidence limit using a LAOCOON method. The temperature dependence of the coupling constants was reproduced from the...

  10. Environmental 90Sr measurements

    USGS Publications Warehouse

    Paul, M.; Berkovits, D.; Cecil, L.D.; Feldstein, H.; Hershkowitz, A.; Kashiv, Y.; Vogt, S.

    1997-01-01

    90Sr (T1/2 = 28.5 years) is a long-lived radionuclide produced in nuclear fission. Fast radiochemical detection of 90Sr in environmental samples is not feasible using current analytical methods. Accelerator Mass Spectrometry (AMS) measurements of 90Sr were made with the Rehovot 14UD Pelletron accelerator at a terminal voltage of 11 or 12 MV using our standard detection system. Injection of hydride ions (SrH3-) was chosen owing to high beam intensity and low Coulomb explosion effects. 90Sr ions were identified and discriminated from isobaric 90Zr by measuring time of flight, total energy and three independent energy-loss signals in an ionization chamber. A reference sample and a ground-water sample were successfully measured. The detection limit determined for a laboratory blank by the residual counts in the 90Sr region is 90Sr/Sr = 3 ?? 10-13, corresponding in practice to (2-4) ?? 10790Sr atoms or about 0.5-1 pCi/L in environmental water samples.

  11. Carter constant and angular momentum

    NASA Astrophysics Data System (ADS)

    Mukherjee, Sajal; Nayak, K. Rajesh

    We investigate the Carter-like constant in the case of a particle moving in a nonrelativistic dipolar potential. This special case is a missing link between the Carter constant in stationary and axially symmetric spacetimes (SASS) such as Kerr solution and its possible Newtonian counterpart. We use this system to carry over the definition of angular momentum from the Newtonian mechanics to the relativistic SASS.

  12. The Conformal Factor and the Cosmological Constant

    NASA Astrophysics Data System (ADS)

    Giddings, Steven B.

    The issue of the conformal factor in quantum gravity is examined for Lorentzian signature spacetimes. In Euclidean signature, the “wrong” sign of the conformal action makes the path integral undefined, but in Lorentzian signature this sign is tied to the instability of gravity and once this is accounted for the path integral should be well-defined. In this approach it is not obvious that the Baum-Hawking-Coleman mechanism for suppression of the cosmological constant functions. It is conceivable that since the multiuniverse system exhibits an instability for positive cosmological constant, the dynamics should force the system to zero cosmological constant.

  13. 40 CFR 86.1309-90 - Exhaust gas sampling system; Otto-cycle and non-petroleum-fueled engines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-cycle and non-petroleum-fueled engines. 86.1309-90 Section 86.1309-90 Protection of Environment... HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty...-cycle and non-petroleum-fueled engines. (a)(1) General. The exhaust gas sampling system described in...

  14. Test and evaluation of constant-flow devices for use in SSN AFFF proportioning systems. Interim report, January-May 1986

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, F.W.; Back, G.G.; Burns, R.E.

    1986-11-04

    Constant flow devices, which deliver a constant flow of liquid over a range of upstream and downstream pressures, have been suggested as an alternative to orifice plates for proportioning AFFF in SSN 21 fire-suppression systems. Operational and performance characteristics of two lightweight, inexpensive, commercially available constant-flow devices have significant advantages over orifice plates. Both models tested, however, showed performance degradation when subjected to simulated service conditions. A constant flow device with improved resistance to wear and to AFFF exposure is desirable. Since the constant-flow control devices tested improves proportioning efficiency but do not have optimum characteristics, investigation of improved devicesmore » or methods is recommended.« less

  15. Prediction of Chain Propagation Rate Constants of Polymerization Reactions in Aqueous NIPAM/BIS and VCL/BIS Systems.

    PubMed

    Kröger, Leif C; Kopp, Wassja A; Leonhard, Kai

    2017-04-06

    Microgels have a wide range of possible applications and are therefore studied with increasing interest. Nonetheless, the microgel synthesis process and some of the resulting properties of the microgels, such as the cross-linker distribution within the microgels, are not yet fully understood. An in-depth understanding of the synthesis process is crucial for designing tailored microgels with desired properties. In this work, rate constants and reaction enthalpies of chain propagation reactions in aqueous N-isopropylacrylamide/N,N'-methylenebisacrylamide and aqueous N-vinylcaprolactam/N,N'-methylenebisacrylamide systems are calculated to identify the possible sources of an inhomogeneous cross-linker distribution in the resulting microgels. Gas-phase reaction rate constants are calculated from B2PLYPD3/aug-cc-pVTZ energies and B3LYPD3/tzvp geometries and frequencies. Then, solvation effects based on COSMO-RS are incorporated into the rate constants to obtain the desired liquid-phase reaction rate constants. The rate constants agree with experiments within a factor of 2-10, and the reaction enthalpies deviate less than 5 kJ/mol. Further, the effect of rate constants on the microgel growth process is analyzed, and it is shown that differences in the magnitude of the reaction rate constants are a source of an inhomogeneous cross-linker distribution within the resulting microgel.

  16. 47 CFR 90.733 - Permissible operations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... ability to construct and operate its nationwide land mobile system, as required in §§ 90.713 (b), (c) and... paging or fixed systems on a primary basis instead of or in addition to its land mobile operations, it... benchmark for the construction of its land mobile system base stations as prescribed in § 90.725(a); and (2...

  17. Systematic harmonic power laws inter-relating multiple fundamental constants

    NASA Astrophysics Data System (ADS)

    Chakeres, Donald; Buckhanan, Wayne; Andrianarijaona, Vola

    2017-01-01

    Power laws and harmonic systems are ubiquitous in physics. We hypothesize that 2, π, the electron, Bohr radius, Rydberg constant, neutron, fine structure constant, Higgs boson, top quark, kaons, pions, muon, Tau, W, and Z when scaled in a common single unit are all inter-related by systematic harmonic powers laws. This implies that if the power law is known it is possible to derive a fundamental constant's scale in the absence of any direct experimental data of that constant. This is true for the case of the hydrogen constants. We created a power law search engine computer program that randomly generated possible positive or negative powers searching when the product of logical groups of constants equals 1, confirming they are physically valid. For 2, π, and the hydrogen constants the search engine found Planck's constant, Coulomb's energy law, and the kinetic energy law. The product of ratios defined by two constants each was the standard general format. The search engine found systematic resonant power laws based on partial harmonic fraction powers of the neutron for all of the constants with products near 1, within their known experimental precision, when utilized with appropriate hydrogen constants. We conclude that multiple fundamental constants are inter-related within a harmonic power law system.

  18. Constant-Time Pattern Matching For Real-Time Production Systems

    NASA Astrophysics Data System (ADS)

    Parson, Dale E.; Blank, Glenn D.

    1989-03-01

    Many intelligent systems must respond to sensory data or critical environmental conditions in fixed, predictable time. Rule-based systems, including those based on the efficient Rete matching algorithm, cannot guarantee this result. Improvement in execution-time efficiency is not all that is needed here; it is important to ensure constant, 0(1) time limits for portions of the matching process. Our approach is inspired by two observations about human performance. First, cognitive psychologists distinguish between automatic and controlled processing. Analogously, we partition the matching process across two networks. The first is the automatic partition; it is characterized by predictable 0(1) time and space complexity, lack of persistent memory, and is reactive in nature. The second is the controlled partition; it includes the search-based goal-driven and data-driven processing typical of most production system programming. The former is responsible for recognition and response to critical environmental conditions. The latter is responsible for the more flexible problem-solving behaviors consistent with the notion of intelligence. Support for learning and refining the automatic partition can be placed in the controlled partition. Our second observation is that people are able to attend to more critical stimuli or requirements selectively. Our match algorithm uses priorities to focus matching. It compares priority of information during matching, rather than deferring this comparison until conflict resolution. Messages from the automatic partition are able to interrupt the controlled partition, enhancing system responsiveness. Our algorithm has numerous applications for systems that must exhibit time-constrained behavior.

  19. 46 CFR 199.90 - Operating instructions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Operating instructions. 199.90 Section 199.90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) LIFESAVING APPLIANCES AND ARRANGEMENTS LIFESAVING SYSTEMS FOR CERTAIN INSPECTED VESSELS Requirements for All Vessels § 199.90 Operating instructions...

  20. New Quasar Studies Keep Fundamental Physical Constant Constant

    NASA Astrophysics Data System (ADS)

    2004-03-01

    certain spectral lines with present-day values. Quasars are here only used as a beacon - the flame - in the very distant Universe. Interstellar clouds of gas in galaxies, located between the quasars and us on the same line of sight and at distances varying from six to eleven thousand of million light years, absorb parts of the light emitted by the quasars. The resulting spectrum consequently presents dark "valleys" that can be attributed to well-known elements. If the fine-structure constant happens to change over the duration of the light's journey, the energy levels in the atoms would be affected and the wavelengths of the absorption lines would be shifted by different amounts. By comparing the relative gaps between the valleys with the laboratory values, it is possible to calculate alpha as a function of distance from us, that is, as a function of the age of the Universe. These measures are however extremely delicate and require a very good modelling of the absorption lines. They also put exceedingly strong requirements on the quality of the astronomical spectra. They must have enough resolution to allow very precise measurement of minuscule shifts in the spectra. And a sufficient number of photons must be captured in order to provide a statistically unambiguous result. For this, astronomers have to turn to the most advanced spectral instruments on the largest telescopes. This is where the Ultra-violet and Visible Echelle Spectrograph (UVES) and ESO's Kueyen 8.2-m telescope at the Paranal Observatory is unbeatable, thanks to the unequalled spectral quality and large collecting mirror area of this combination. Constant or not? ESO PR Photo 07/04 ESO PR Photo 07/04 Relative Changes with Redshift of the Fine Structure Constant [Preview - JPEG: 496 x 400 pix - 36k] [Normal - JPEG: 991 x 800 pix - 320k] Captions: ESO PR Photo 07/04 shows measured values of the relative change of alpha from the sample of absorption systems studied by Hum Chand and his colleagues, plotted as

  1. Preliminary Planck constant measurements via UME oscillating magnet Kibble balance

    NASA Astrophysics Data System (ADS)

    Ahmedov, H.; Babayiğit Aşkın, N.; Korutlu, B.; Orhan, R.

    2018-06-01

    The UME Kibble balance project was initiated in the second half of 2014. During this period we have studied the theoretical aspects of Kibble balances, in which an oscillating magnet generates AC Faraday’s voltage in a stationary coil, and constructed a trial version to implement this idea. The remarkable feature of this approach is that it can establish the link between the Planck constant and a macroscopic mass by one single experiment in the most natural way. Weak dependences on variations of environmental and experimental conditions, small size, and other useful features offered by this novel approach reduce the complexity of the experimental set-up. This paper describes the principles of the oscillating magnet Kibble balance and gives details of the preliminary Planck constant measurements. The value of the Planck constant determined with our apparatus is \\boldsymbol{h}/{{\\boldsymbol{h}}\\boldsymbol 90}={1}{.000} {004}~ , with a relative standard uncertainty of 6 ppm.

  2. 47 CFR 90.625 - Other criteria to be applied in assigning channels for use in conventional systems of communication.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... channels for use in conventional systems of communication. 90.625 Section 90.625 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES... applied in assigning channels for use in conventional systems of communication. (a) Where an applicant...

  3. Controllability of impulse controlled systems of heat equations coupled by constant matrices

    NASA Astrophysics Data System (ADS)

    Qin, Shulin; Wang, Gengsheng

    2017-11-01

    This paper studies the approximate and null controllability for impulse controlled systems of heat equations coupled by a pair (A , B) of constant matrices. We present a necessary and sufficient condition for the approximate controllability, which is exactly Kalman's controllability rank condition of (A , B). We prove that when such a system is approximately controllable, the approximate controllability over an interval [ 0 , T ] can be realized by adding controls at arbitrary q (A , B) different control instants 0 <τ1 <τ2 < ⋯ <τ q (A , B) < T, provided that τ q (A , B) -τ1 systems are not null controllable.

  4. Constants and pseudo-constants of the Kadomtsev-Petviashvili equation.

    PubMed

    Case, K M

    1985-08-01

    Elucidating earlier work, it is shown that the Kadomtsev-Petviashvili equation has n + 2 constants for all n >/= 0. It also has a pseudo-constant from which the constants can be obtained by differentiation with respect to time. The pseudo-constant can be obtained from a basis functional J(n) ((n+2)) = -1/18 [unk] y(n+2)q by taking repeated Poisson brackets with the Hamiltonian.

  5. 46 CFR 133.90 - Operating instructions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Operating instructions. 133.90 Section 133.90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS LIFESAVING SYSTEMS Requirements for All OSVs § 133.90 Operating instructions. Each OSV must have posters or signs displayed in the...

  6. 46 CFR 133.90 - Operating instructions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Operating instructions. 133.90 Section 133.90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS LIFESAVING SYSTEMS Requirements for All OSVs § 133.90 Operating instructions. Each OSV must have posters or signs displayed in the...

  7. 46 CFR 133.90 - Operating instructions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Operating instructions. 133.90 Section 133.90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS LIFESAVING SYSTEMS Requirements for All OSVs § 133.90 Operating instructions. Each OSV must have posters or signs displayed in the...

  8. 46 CFR 133.90 - Operating instructions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Operating instructions. 133.90 Section 133.90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS LIFESAVING SYSTEMS Requirements for All OSVs § 133.90 Operating instructions. Each OSV must have posters or signs displayed in the...

  9. 46 CFR 133.90 - Operating instructions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Operating instructions. 133.90 Section 133.90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS LIFESAVING SYSTEMS Requirements for All OSVs § 133.90 Operating instructions. Each OSV must have posters or signs displayed in the...

  10. Reaction rate constants and mean population percentage for nitrifiers in an alternating oxidation ditch system.

    PubMed

    Mantziaras, I D; Katsiri, A

    2011-01-01

    This paper presents a methodology for the determination of reaction rate constants for nitrifying bacteria and their mean population percentage in biomass in an alternating oxidation ditch system. The method used is based on the growth rate equations of the ASM1 model (IWA) (Henze et al. in Activated sludge models ASM1, ASM2, ASM2d, and ASM3. IWA Scientific and Technical Report no. 9, IWA Publishing, London, UK, 2000) and the application of mass balance equations for nitrifiers and ammonium nitrogen in an operational cycle of the ditch system. The system consists of two ditches operating in four phases. Data from a large-scale oxidation ditch pilot plant with a total volume of 120 m(3) within an experimental period of 8 months was used. Maximum specific growth rate for autotrophs (μ(A)) and the half-saturation constant for ammonium nitrogen (K(NH)) were found to be 0.36 day(-1) and 0.65 mgNH(4)-N/l, respectively. Additionally, the average population percentage of the nitrifiers in the biomass was estimated to be around 3%.

  11. Constant-current control method of multi-function electromagnetic transmitter.

    PubMed

    Xue, Kaichang; Zhou, Fengdao; Wang, Shuang; Lin, Jun

    2015-02-01

    Based on the requirements of controlled source audio-frequency magnetotelluric, DC resistivity, and induced polarization, a constant-current control method is proposed. Using the required current waveforms in prospecting as a standard, the causes of current waveform distortion and current waveform distortion's effects on prospecting are analyzed. A cascaded topology is adopted to achieve 40 kW constant-current transmitter. The responsive speed and precision are analyzed. According to the power circuit of the transmitting system, the circuit structure of the pulse width modulation (PWM) constant-current controller is designed. After establishing the power circuit model of the transmitting system and the PWM constant-current controller model, analyzing the influence of ripple current, and designing an open-loop transfer function according to the amplitude-frequency characteristic curves, the parameters of the PWM constant-current controller are determined. The open-loop transfer function indicates that the loop gain is no less than 28 dB below 160 Hz, which assures the responsive speed of the transmitting system; the phase margin is 45°, which assures the stabilization of the transmitting system. Experimental results verify that the proposed constant-current control method can keep the control error below 4% and can effectively suppress load change caused by the capacitance of earth load.

  12. Constant-current control method of multi-function electromagnetic transmitter

    NASA Astrophysics Data System (ADS)

    Xue, Kaichang; Zhou, Fengdao; Wang, Shuang; Lin, Jun

    2015-02-01

    Based on the requirements of controlled source audio-frequency magnetotelluric, DC resistivity, and induced polarization, a constant-current control method is proposed. Using the required current waveforms in prospecting as a standard, the causes of current waveform distortion and current waveform distortion's effects on prospecting are analyzed. A cascaded topology is adopted to achieve 40 kW constant-current transmitter. The responsive speed and precision are analyzed. According to the power circuit of the transmitting system, the circuit structure of the pulse width modulation (PWM) constant-current controller is designed. After establishing the power circuit model of the transmitting system and the PWM constant-current controller model, analyzing the influence of ripple current, and designing an open-loop transfer function according to the amplitude-frequency characteristic curves, the parameters of the PWM constant-current controller are determined. The open-loop transfer function indicates that the loop gain is no less than 28 dB below 160 Hz, which assures the responsive speed of the transmitting system; the phase margin is 45°, which assures the stabilization of the transmitting system. Experimental results verify that the proposed constant-current control method can keep the control error below 4% and can effectively suppress load change caused by the capacitance of earth load.

  13. Constants and pseudo-constants of the Kadomtsev-Petviashvili equation

    PubMed Central

    Case, K. M.

    1985-01-01

    Elucidating earlier work, it is shown that the Kadomtsev-Petviashvili equation has n + 2 constants for all n ≥ 0. It also has a pseudo-constant from which the constants can be obtained by differentiation with respect to time. The pseudo-constant can be obtained from a basis functional Jn(n+2) = -1/18 [unk] yn+2q by taking repeated Poisson brackets with the Hamiltonian. PMID:16593588

  14. Local heat transfer distribution in a square channel with 90 continuous, 90 saw tooth profiled and 60 broken ribs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gupta, Abhishek; SriHarsha, V.; Prabhu, S.V.

    2008-02-15

    Internal channel cooling is employed in advanced gas turbines blade to allow high inlet temperatures so as to achieve high thrust/weight ratios and low specific fuel consumption. The objective of the present study is to measure the local heat transfer distributions in a double wall ribbed square channel with 90 continuous, 90 saw tooth profiled and 60 V-broken ribs. Comparison is made between the 90 continuous ribs (P/e = 7 and 10 for a e/D = 0.15) and 90 saw tooth profiled rib configurations (P/e = 7 for an e/D = 0.15) for the same rib height to the hydraulicmore » diameter ratio (e/D). The effect of pitch to rib height ratio (P/e = 7.5,10 and 12) of 60 V-broken ribbed channel with a constant rib height to hydraulic diameter ratio (e/D) of 0.0625 on the local heat transfer distribution is studied. The Reynolds number based on duct hydraulic diameter is ranging from 10,000 to 30,000. A thin stainless steel foil of 0.05 mm thickness is used as heater and infrared thermography technique is used to obtain the local temperature distribution on the surface. The images are captured in the periodically fully developed region of the channel. It is observed that the heat transfer augmentations in the channel with 90 saw tooth profiled ribs are comparable with those of 90 continuous ribs. The enhancements caused by 60 V-broken ribs are higher than those of 90 continuous ribs. The effect of pitch to the rib height ratio (P/e) is not significant for channel with 60 V-broken ribs for a given rib height to hydraulic diameter ratio (e/D = 0.0625). (author)« less

  15. Elastic constants from microscopic strain fluctuations

    PubMed

    Sengupta; Nielaba; Rao; Binder

    2000-02-01

    Fluctuations of the instantaneous local Lagrangian strain epsilon(ij)(r,t), measured with respect to a static "reference" lattice, are used to obtain accurate estimates of the elastic constants of model solids from atomistic computer simulations. The measured strains are systematically coarse-grained by averaging them within subsystems (of size L(b)) of a system (of total size L) in the canonical ensemble. Using a simple finite size scaling theory we predict the behavior of the fluctuations as a function of L(b)/L and extract elastic constants of the system in the thermodynamic limit at nonzero temperature. Our method is simple to implement, efficient, and general enough to be able to handle a wide class of model systems, including those with singular potentials without any essential modification. We illustrate the technique by computing isothermal elastic constants of "hard" and "soft" disk triangular solids in two dimensions from Monte Carlo and molecular dynamics simulations. We compare our results with those from earlier simulations and theory.

  16. Anticancer Inhibitors of Hsp90 Function: Beyond the Usual Suspects

    PubMed Central

    Garg, Gaurav; Khandelwal, Anuj; Blagg, Brian S.J.

    2018-01-01

    The 90-kDa heat-shock protein (Hsp90) is a molecular chaperone responsible for the stability and function of a wide variety of client proteins that are critical for cell growth and survival. Many of these client proteins are frequently mutated and/or overexpressed in cancer cells and are therefore being actively pursued as individual therapeutic targets. Consequently, Hsp90 inhibition offers a promising strategy for simultaneous degradation of several anticancer targets. Currently, most Hsp90 inhibitors under clinical evaluation act by blocking the binding of ATP to the Hsp90 N-terminal domain and thereby, induce the degradation of many Hsp90-dependent oncoproteins. Although, they have shown some promising initial results, clinical challenges such as induction of the heat-shock response, retinopathy, and gastrointestinal tract toxicity are emerging from human trials, which constantly raise concerns about the future development of these inhibitors. Novobiocin derivatives, which do not bind the chaperone’s N-terminal ATPase pocket, have emerged over the past decade as an alternative strategy to inhibit Hsp90, but to date, no derivative has been investigated in the clinical setting. In recent years, a number of natural or synthetic compounds have been identified that modulate Hsp90 function via various mechanisms. These compounds not only offer new chemotypes for the development of future Hsp90 inhibitors but can also serve as chemical probes to unravel the biology of Hsp90. This chapter presents a synopsis of inhibitors that directly, allosterically, or even indirectly alters Hsp90 function, and highlights their proposed mechanisms of action. PMID:26916001

  17. Methodology for extracting local constants from petroleum cracking flows

    DOEpatents

    Chang, Shen-Lin; Lottes, Steven A.; Zhou, Chenn Q.

    2000-01-01

    A methodology provides for the extraction of local chemical kinetic model constants for use in a reacting flow computational fluid dynamics (CFD) computer code with chemical kinetic computations to optimize the operating conditions or design of the system, including retrofit design improvements to existing systems. The coupled CFD and kinetic computer code are used in combination with data obtained from a matrix of experimental tests to extract the kinetic constants. Local fluid dynamic effects are implicitly included in the extracted local kinetic constants for each particular application system to which the methodology is applied. The extracted local kinetic model constants work well over a fairly broad range of operating conditions for specific and complex reaction sets in specific and complex reactor systems. While disclosed in terms of use in a Fluid Catalytic Cracking (FCC) riser, the inventive methodology has application in virtually any reaction set to extract constants for any particular application and reaction set formulation. The methodology includes the step of: (1) selecting the test data sets for various conditions; (2) establishing the general trend of the parametric effect on the measured product yields; (3) calculating product yields for the selected test conditions using coupled computational fluid dynamics and chemical kinetics; (4) adjusting the local kinetic constants to match calculated product yields with experimental data; and (5) validating the determined set of local kinetic constants by comparing the calculated results with experimental data from additional test runs at different operating conditions.

  18. Constants and pseudo-constants of the Kadomtsev-Petviashvili equation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Case, K.M.

    1985-08-01

    Elucidating earlier work, it is shown that the Kadomtsev-Petviashvili equation has n + 2 constants for all n greater than or equal to 0. It also has a pseudo-constant from which the constants can be obtained by differentiation with respect to time. The pseudo-constant can be obtained from a basis functional J/sub n/sup (n+2)/ = -1/18 integral y/sup n+2/ q by taking repeated Poisson brackets with the Hamiltonian.

  19. 47 CFR 90.350 - Scope.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Scope. 90.350 Section 90.350 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO... Systems radio service is for the purpose of integrating radio-based technologies into the nation's...

  20. The 2016 HIV diagnosis and care cascade in New South Wales, Australia: meeting the UNAIDS 90-90-90 targets.

    PubMed

    Keen, Phillip; Gray, Richard T; Telfer, Barbara; Guy, Rebecca; Schmidt, Heather-Marie; Whittaker, Bill; Holden, Jo; Holt, Martin; Kelleher, Anthony; Wilson, David; Callander, Denton; Cooper, David A; Prestage, Garrett; Selvey, Christine; Grulich, Andrew E

    2018-04-01

    The HIV Strategy in New South Wales (NSW) Australia aims to virtually eliminate HIV transmission by 2020. We estimated the 2016 HIV diagnosis and care cascade for the state of NSW, with a focus on introducing population-based data to improve data quality and assess progress towards the UNAIDS 90-90-90 targets. To estimate the number of people living with diagnosed HIV (PLDHIV) we used NSW data from the Australian National HIV Registry, enhanced by surveillance among people recently diagnosed with HIV to improve migration estimates. The number of undiagnosed PLHIV was estimated using back-projection modelling by CD4 count at diagnosis. De-duplicated prescription claims data were obtained from the Australian Pharmaceutical Benefits Scheme (PBS), and were combined with an estimate for those ineligible, to determine the number of PLDHIV on antiretroviral therapy (ART). Data from a clinic network with 87% coverage of PLDHIV in NSW enabled the estimation of the number on ART who had HIV suppression. We estimated that 10,110 PLHIV resided in NSW in 2016 (range 8400 to 11,720), among whom 9230 (91.3%) were diagnosed, and 8490 (92.0% of those diagnosed) were receiving ART. Among PLDHIV receiving ART, 8020 (94.5%) had suppressed viral load (<200 HIV-1 RNA copies/mL). Overall, 79.3% of all PLHIV had HIV virological suppression. NSW has met each of the UNAIDS 90-90-90 targets. The enhanced surveillance methods and data collection systems improved data quality. Measuring and meeting the 90-90-90 targets is feasible and could be achieved in comparable parts of the world. © 2018 The Authors. Journal of the International AIDS Society published by John Wiley & sons Ltd on behalf of the International AIDS Society.

  1. 47 CFR 90.521 - Scope.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... systems operating in the 763-775 MHz and 793-805 MHz frequency bands. It includes eligibility, operational... 47 Telecommunication 5 2011-10-01 2011-10-01 false Scope. 90.521 Section 90.521 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO...

  2. Ligand Desolvation Steers On-Rate and Impacts Drug Residence Time of Heat Shock Protein 90 (Hsp90) Inhibitors.

    PubMed

    Schuetz, Doris A; Richter, Lars; Amaral, Marta; Grandits, Melanie; Grädler, Ulrich; Musil, Djordje; Buchstaller, Hans-Peter; Eggenweiler, Hans-Michael; Frech, Matthias; Ecker, Gerhard F

    2018-05-24

    Residence time and more recently the association rate constant k on are increasingly acknowledged as important parameters for in vivo efficacy and safety of drugs. However, their broader consideration in drug development is limited by a lack of knowledge of how to optimize these parameters. In this study on a set of 176 heat shock protein 90 inhibitors, structure-kinetic relationships, X-ray crystallography, and molecular dynamics simulations were combined to retrieve a concrete scheme of how to rationally slow down on-rates. We discovered that an increased ligand desolvation barrier by introducing polar substituents resulted in a significant k on decrease. The slowdown was accomplished by introducing polar moieties to those parts of the ligand that point toward a hydrophobic cavity. We validated this scheme by increasing polarity of three Hsp90 inhibitors and observed a 9-, 13-, and 45-fold slowdown of on-rates and a 9-fold prolongation in residence time. This prolongation was driven by transition state destabilization rather than ground state stabilization.

  3. Simple constant-current-regulated power supply

    NASA Technical Reports Server (NTRS)

    Priebe, D. H. E.; Sturman, J. C.

    1977-01-01

    Supply incorporates soft-start circuit that slowly ramps current up to set point at turn-on. Supply consists of full-wave rectifier, regulating pass transistor, current feedback circuit, and quad single-supply operational-amplifier circuit providing control. Technique is applicable to any system requiring constant dc current, such as vacuum tube equipment, heaters, or battery charges; it has been used to supply constant current for instrument calibration.

  4. 2D constant-loss taper for mode conversion

    NASA Astrophysics Data System (ADS)

    Horth, Alexandre; Kashyap, Raman; Quitoriano, Nathaniel J.

    2015-03-01

    Proposed in this manuscript is a novel taper geometry, the constant-loss taper (CLT). This geometry is derived with 1D slabs of silicon embedded in silicon dioxide using coupled-mode theory (CMT). The efficiency of the CLT is compared to both linear and parabolic tapers using CMT and 2D finite-difference time-domain simulations. It is shown that over a short 2D, 4.45 μm long taper the CLT's mode conversion efficiency is ~90% which is 10% and 18% more efficient than a 2D parabolic or linear taper, respectively.

  5. 46 CFR 56.90-1 - General.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false General. 56.90-1 Section 56.90-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Assembly § 56.90-1 General. (a) The assembly of the various piping components, whether done in a shop or as field...

  6. 46 CFR 56.90-1 - General.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false General. 56.90-1 Section 56.90-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Assembly § 56.90-1 General. (a) The assembly of the various piping components, whether done in a shop or as field...

  7. 46 CFR 56.90-1 - General.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false General. 56.90-1 Section 56.90-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Assembly § 56.90-1 General. (a) The assembly of the various piping components, whether done in a shop or as field...

  8. 46 CFR 56.90-1 - General.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false General. 56.90-1 Section 56.90-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Assembly § 56.90-1 General. (a) The assembly of the various piping components, whether done in a shop or as field...

  9. 46 CFR 56.90-1 - General.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false General. 56.90-1 Section 56.90-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Assembly § 56.90-1 General. (a) The assembly of the various piping components, whether done in a shop or as field...

  10. The generalized Weierstrass system inducing surfaces of constant and nonconstant mean curvature in Euclidean three space

    NASA Astrophysics Data System (ADS)

    Bracken, Paul

    2007-05-01

    The generalized Weierstrass (GW) system is introduced and its correspondence with the associated two-dimensional nonlinear sigma model is reviewed. The method of symmetry reduction is systematically applied to derive several classes of invariant solutions for the GW system. The solutions can be used to induce constant mean curvature surfaces in Euclidean three space. Some properties of the system for the case of nonconstant mean curvature are introduced as well.

  11. 47 CFR 90.672 - Unacceptable interference to non-cellular 800 MHz licensees from 800 MHz cellular systems or part...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Unacceptable interference to non-cellular 800 MHz licensees from 800 MHz cellular systems or part 22 Cellular Radiotelephone systems, and within the 900 MHz Business/Industrial Land Transportation Pool. 90.672 Section 90.672 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY...

  12. A 90GHz Bolometer Camera Detector System for the Green

    NASA Technical Reports Server (NTRS)

    Benford, Dominic J.; Allen, Christine A.; Buchanan, Ernest; Chen, Tina C.; Chervenak, James A.; Devlin, Mark J.; Dicker, Simon R.; Forgione, Joshua B.

    2004-01-01

    We describe a close-packed, two-dimensional imaging detector system for operation at 90GHz (3.3 mm) for the 100m Green Bank Telescope (GBT). This system will provide high sensitivity (less than 1mJy in 1s) rapid imaging (15'x15' to 150 micron Jy in 1 hr) at the world's largest steerable aperture. The heart of this camera is an 8x8 close-packed, Nyquist-sampled array of superconducting transition edge sensor (TES) bolometers. We have designed and are producing a functional superconducting bolometer array system using a monolithic planar architecture and high-speed multiplexed readout electronics. With an NEP of approximately 2 x 10(exp -17) W/square root of Hz, the TES bolometers will provide fast, linear, sensitive response for high performance imaging. The detectors are read out by an 8x8 time domain SQUID multiplexer. A digital/analog electronics system has been designed to enable read out by SQUID multiplexers. First light for this instrument on the GBT is expected within a year.

  13. 47 CFR 90.683 - EA-based SMR system operations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... operate base stations using any of the base station frequencies identified in their spectrum block... base stations at any location on the border of the EA service area in accordance with § 90.689; (4... with § 90.621(b), to all previously authorized co-channel stations that are not associated with another...

  14. Reports on Astronomical Constants

    NASA Astrophysics Data System (ADS)

    Fukushima, Toshio

    Recent progress in the determination of astronomical constants is reviewed. By using the latest numerical integration of LC (Irwin and Fukushima, 1999) and the latest value of the geoidal potential W0 (Groten, 1999), we reestimated the general relativistic scale constants as LC = 1.480~826~867~4 × 10-8 ± 1.4 × 10-17, LG = 6.969~290~13 × 10-10 ± 6 × 10-18, and LB = 1.550~519~767~5 × 10-8 ± 2.0 × 10-17. Presented is a proposal to fix the numerical value of LG as the above in order to remove the geophysical ambiguity in its evaluation in the future. Next focused upon is the correction to the IAU 1976 Precession (Lieske et al., 1977). By simply averaging the latest VLBI-based determinations (Mathews et al., 2000; Petrov, 2000; Shirai and Fukushima, 2000; Vondrak and Ron, 2000) and the latest LLR-based determinations (Chapront et al., 1999), we obtained the best estimates of precession-related quantities at J2000.0: the general precession in longitude, p = 5~028.78 ± 0.03 ''/cy; obliquity of the ecliptic, ɛ0 = 23o26'21.''405~6 ± 0.''0005; and the pole offsets of the CEP of ICRS, Δ ψ0 sin ɛ0 = (-17.5 ± 0.8) mas, and Δ ɛ0 = (-5.2 ± 0.4) mas. After quoting the latest determination of mass of Pluto-Charon system (Tholen and Buie, 1997) and the recent change of G (Mohr and Taylor, 1999), proposed is a draft IAU 2000 File of Current Best Estimates of Astronomical Constants to replace the former 1994 version (Standish, 1995). It may even supplant the IAU 1976 System of Astronomical Constants (Duncombe et al., 1977), subject to discussion at this General Assembly.

  15. Gravitational Waves from Isolated Systems: Surprising Consequences of a Positive Cosmological Constant.

    PubMed

    Ashtekar, Abhay; Bonga, Béatrice; Kesavan, Aruna

    2016-02-05

    There is a deep tension between the well-developed theory of gravitational waves from isolated systems and the presence of a positive cosmological constant Λ, however tiny. In particular a generalization of Einstein's 1918 quadrupole formula that would allow a positive Λ is not yet available. We first explain the principal difficulties and then show that it is possible to overcome them in the weak field limit. These results also provide concrete hints for constructing the Λ>0 generalization of the Bondi-Sachs framework for full, nonlinear general relativity.

  16. Gravitational Waves from Isolated Systems: Surprising Consequences of a Positive Cosmological Constant

    NASA Astrophysics Data System (ADS)

    Ashtekar, Abhay; Bonga, Béatrice; Kesavan, Aruna

    2016-02-01

    There is a deep tension between the well-developed theory of gravitational waves from isolated systems and the presence of a positive cosmological constant Λ , however tiny. In particular a generalization of Einstein's 1918 quadrupole formula that would allow a positive Λ is not yet available. We first explain the principal difficulties and then show that it is possible to overcome them in the weak field limit. These results also provide concrete hints for constructing the Λ >0 generalization of the Bondi-Sachs framework for full, nonlinear general relativity.

  17. Method of separation of yttrium-90 from strontium-90

    DOEpatents

    Bray, Lane A.; Wester, Dennis W.

    1996-01-01

    A method for purifying Y-90 from a Sr-90/Y-90 "cow" wherein raw Sr-90/Y-90 source containing impurities is obtained from nuclear material reprocessing. Raw Sr-90/Y-90 source is purified to a fresh Sr-90/Y-90 source "cow" by removing impurities by addition of sodium hydroxide and by removing Cs-137 by further addition of sodium carbonate. The "cow" is set aside to allow ingrowth. An HDEHP organic extractant is obtained from a commercial supplier and further purified by saturation with Cu(II), precipitation with acetone, and washing with nitric acid. The "cow" is then dissolved in nitric acid and the purified HDEHP is washed with nitric acid and scrubbed with either nitric or hydrochloric acid. The dissolved "cow" and scrubbed HDEHP are combined in an organic extraction, separating Y-90 from Sr-90, resulting in a Sr-90/Y-90 concentration ratio of not more than 10(E-7), and a metal impurity concentration of not more than 10 ppm per curie of Y-90. The separated Y-90 may then be prepared for delivery.

  18. Quantification of root gravitropic response using a constant stimulus feedback system.

    PubMed

    Wolverton, Chris

    2015-01-01

    Numerous software packages now exist for quantifying root growth responses, most of which analyze a time resolved sequence of images ex post facto. However, few allow for the real-time analysis of growth responses. The system in routine use in our lab allows for real-time growth analysis and couples this to positional feedback to control the stimulus experienced by the responding root. This combination allows us to overcome one of the confounding variables in studies of root gravity response. Seedlings are grown on standard petri plates attached to a vertical rotating stage and imaged using infrared illumination. The angle of a particular region of the root is determined by image analysis, compared to the prescribed angle, and any corrections in positioning are made by controlling a stepper motor. The system allows for the long-term stimulation of a root at a constant angle and yields insights into the gravity perception and transduction machinery not possible with other approaches.

  19. Automatic Exposure Control Systems Designed to Maintain Constant Image Noise: Effects on Computed Tomography Dose and Noise Relative to Clinically Accepted Technique Charts

    PubMed Central

    Favazza, Christopher P.; Yu, Lifeng; Leng, Shuai; Kofler, James M.; McCollough, Cynthia H.

    2015-01-01

    Objective To compare computed tomography dose and noise arising from use of an automatic exposure control (AEC) system designed to maintain constant image noise as patient size varies with clinically accepted technique charts and AEC systems designed to vary image noise. Materials and Methods A model was developed to describe tube current modulation as a function of patient thickness. Relative dose and noise values were calculated as patient width varied for AEC settings designed to yield constant or variable noise levels and were compared to empirically derived values used by our clinical practice. Phantom experiments were performed in which tube current was measured as a function of thickness using a constant-noise-based AEC system and the results were compared with clinical technique charts. Results For 12-, 20-, 28-, 44-, and 50-cm patient widths, the requirement of constant noise across patient size yielded relative doses of 5%, 14%, 38%, 260%, and 549% and relative noises of 435%, 267%, 163%, 61%, and 42%, respectively, as compared with our clinically used technique chart settings at each respective width. Experimental measurements showed that a constant noise–based AEC system yielded 175% relative noise for a 30-cm phantom and 206% relative dose for a 40-cm phantom compared with our clinical technique chart. Conclusions Automatic exposure control systems that prescribe constant noise as patient size varies can yield excessive noise in small patients and excessive dose in obese patients compared with clinically accepted technique charts. Use of noise-level technique charts and tube current limits can mitigate these effects. PMID:25938214

  20. Automatic exposure control systems designed to maintain constant image noise: effects on computed tomography dose and noise relative to clinically accepted technique charts.

    PubMed

    Favazza, Christopher P; Yu, Lifeng; Leng, Shuai; Kofler, James M; McCollough, Cynthia H

    2015-01-01

    To compare computed tomography dose and noise arising from use of an automatic exposure control (AEC) system designed to maintain constant image noise as patient size varies with clinically accepted technique charts and AEC systems designed to vary image noise. A model was developed to describe tube current modulation as a function of patient thickness. Relative dose and noise values were calculated as patient width varied for AEC settings designed to yield constant or variable noise levels and were compared to empirically derived values used by our clinical practice. Phantom experiments were performed in which tube current was measured as a function of thickness using a constant-noise-based AEC system and the results were compared with clinical technique charts. For 12-, 20-, 28-, 44-, and 50-cm patient widths, the requirement of constant noise across patient size yielded relative doses of 5%, 14%, 38%, 260%, and 549% and relative noises of 435%, 267%, 163%, 61%, and 42%, respectively, as compared with our clinically used technique chart settings at each respective width. Experimental measurements showed that a constant noise-based AEC system yielded 175% relative noise for a 30-cm phantom and 206% relative dose for a 40-cm phantom compared with our clinical technique chart. Automatic exposure control systems that prescribe constant noise as patient size varies can yield excessive noise in small patients and excessive dose in obese patients compared with clinically accepted technique charts. Use of noise-level technique charts and tube current limits can mitigate these effects.

  1. Facilities and support systems for a 90-day test of a regenerative life support system

    NASA Technical Reports Server (NTRS)

    Malin, R. L.

    1972-01-01

    A 90-day test is reported of a regenerative life support system which was completed in a space station simulator. The long duration of the test and the fact that it was manned, imposed rigid reliability and safety requirements on the facility. Where adequate reliability could not be built into essential facility systems, either backup systems or components were provided. Awareness was intensified by: (1) placing signs on every piece of equipment that could affect the test, (2) painting switches on all breaker panels a bright contrasting color, (3) restricting access to the test control area, and (4) informing personnel in the facility (other than test personnel) of test activities. It is concluded that the basic facility is satisfactory for conducting long-duration manned tests, and it is recommended that all monitor and alarm functions be integrated into a single operation.

  2. Present status of astronomical constants

    NASA Astrophysics Data System (ADS)

    Fukushima, T.

    Given was the additional information to the previous report on the recent progress in the determinations of astronomical constants (Fukushima 2000). First noted was the revision of LG as 6.969290134×10-10 based on the proposal to shift its status from a primary to a defining constant (Petit 2000). Next focused was the significant update of the correction to the current precession constant, Δp, based on the recent LLR-based determination (Chapront et al. 2000) as -0.3164+/-0.0030"/cy. By combining this and the equal weighted average of VLBI determinations (Mathews et al. 2000; Petrov 2000; Shirai and Fukushima 2000; Vondrak and Ron 2000) as -0.2968+/-0.0043"/cy, we derived the best estimate of precession constant as p = 5028.790+/-0.005"/cy. Also redetermined were some other quantities related to the precession formula; namely the offsets of Celestial Ephemeris Pole of the International Celestial Reference System as &Deltaψ0sinɛ0 = (-17.0+/-0.3) mas and Δɛ0 = (-5.1+/-0.3) mas. As a result, the obliquity of the ecliptic at the epoch J2000.0 was estimated as ɛ0 = 23°26'21."4059+/-0."0003. As a summary, presented was the (revised) IAU 2000 File of Current Best Estimates of astronomical constants, which is to replace the former 1994 version (Standish 1995).

  3. Variable energy constant current accelerator structure

    DOEpatents

    Anderson, Oscar A.

    1990-01-01

    A variable energy, constant current ion beam accelerator structure is disclosed comprising an ion source capable of providing the desired ions, a pre-accelerator for establishing an initial energy level, a matching/pumping module having means for focusing means for maintaining the beam current, and at least one main accelerator module for continuing beam focus, with means capable of variably imparting acceleration to the beam so that a constant beam output current is maintained independent of the variable output energy. In a preferred embodiment, quadrupole electrodes are provided in both the matching/pumping module and the one or more accelerator modules, and are formed using four opposing cylinder electrodes which extend parallel to the beam axis and are spaced around the beam at 90.degree. intervals with opposing electrodes maintained at the same potential. Adjacent cylinder electrodes of the quadrupole structure are maintained at different potentials to thereby reshape the cross section of the charged particle beam to an ellipse in cross section at the mid point along each quadrupole electrode unit in the accelerator modules. The beam is maintained in focus by alternating the major axis of the ellipse along the x and y axis respectively at adjacent quadrupoles. In another embodiment, electrostatic ring electrodes may be utilized instead of the quadrupole electrodes.

  4. Method of separation of yttrium-90 from strontium-90

    DOEpatents

    Bray, L.A.; Wester, D.W.

    1996-04-30

    A method is described for purifying Y-90 from a Sr-90/Y-90 ``cow`` wherein raw Sr-90/Y-90 source containing impurities is obtained from nuclear material reprocessing. Raw Sr-90/Y-90 source is purified to a fresh Sr-90/Y-90 source ``cow`` by removing impurities by addition of sodium hydroxide and by removing Cs-137 by further addition of sodium carbonate. The ``cow`` is set aside to allow ingrowth. An HDEHP organic extractant is obtained from a commercial supplier and further purified by saturation with Cu(II), precipitation with acetone, and washing with nitric acid. The ``cow`` is then dissolved in nitric acid and the purified HDEHP is washed with nitric acid and scrubbed with either nitric or hydrochloric acid. The dissolved ``cow`` and scrubbed HDEHP are combined in an organic extraction, separating Y-90 from Sr-90, resulting in a Sr-90/Y-90 concentration ratio of not more than 10(E-7), and a metal impurity concentration of not more than 10 ppm per curie of Y-90. The separated Y-90 may then be prepared for delivery. 1 fig.

  5. Algorithm for Calculating the Dissociation Constants of Ampholytes in Nonbuffer Systems

    NASA Astrophysics Data System (ADS)

    Lysova, S. S.; Skripnikova, T. A.; Zevatskii, Yu. E.

    2018-05-01

    An algorithm for calculating the dissociation constants of ampholytes in aqueous solutions is developed on the basis of spectrophotometric data in the UV and visible ranges without pH measurements of a medium and without buffer solutions. The proposed algorithm has been experimentally tested for five ampholytes of different strengths. The relative error of measuring dissociation constants is less than 5%.

  6. SU-E-CAMPUS-I-06: Y90 PET/CT for the Instantaneous Determination of Both Target and Non-Target Absorbed Doses Following Hepatic Radioembolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pasciak, A; Kao, J

    2014-06-15

    Purpose The process of converting Yttrium-90 (Y90) PET/CT images into 3D absorbed dose maps will be explained. The simple methods presented will allow the medical physicst to analyze Y90 PET images following radioembolization and determine the absorbed dose to tumor, normal liver parenchyma and other areas of interest, without application of Monte-Carlo radiation transport or dose-point-kernel (DPK) convolution. Methods Absorbed dose can be computed from Y90 PET/CT images based on the premise that radioembolization is a permanent implant with a constant relative activity distribution after infusion. Many Y90 PET/CT publications have used DPK convolution to obtain 3D absorbed dose maps.more » However, this method requires specialized software limiting clinical utility. The Local Deposition method, an alternative to DPK convolution, can be used to obtain absorbed dose and requires no additional computer processing. Pixel values from regions of interest drawn on Y90 PET/CT images can be converted to absorbed dose (Gy) by multiplication with a scalar constant. Results There is evidence that suggests the Local Deposition method may actually be more accurate than DPK convolution and it has been successfully used in a recent Y90 PET/CT publication. We have analytically compared dose-volume-histograms (DVH) for phantom hot-spheres to determine the difference between the DPK and Local Deposition methods, as a function of PET scanner point-spread-function for Y90. We have found that for PET/CT systems with a FWHM greater than 3.0 mm when imaging Y90, the Local Deposition Method provides a more accurate representation of DVH, regardless of target size than DPK convolution. Conclusion Using the Local Deposition Method, post-radioembolization Y90 PET/CT images can be transformed into 3D absorbed dose maps of the liver. An interventional radiologist or a Medical Physicist can perform this transformation in a clinical setting, allowing for rapid prediction of treatment efficacy

  7. Thermomagnetic recording and magneto-optic playback system having constant intensity laser beam control

    NASA Technical Reports Server (NTRS)

    Lewicki, G. W.; Guisinger, J. E. (Inventor)

    1973-01-01

    A system is developed for maintaining the intensity of a laser beam at a constant level in a thermomagnetic recording and magneto-optic playback system in which an isotropic film is heated along a continuous path by the laser beam for recording. As each successive area of the path is heated locally to the vicinity of its Curie point in the presence of a controlled magnetic field, a magneto-optic density is produced proportional to the amplitude of the controlled magnetic field. To play back the recorded signal, the intensity of the laser beam is reduced and a Faraday or Kerr effect analyzer is used, with a photodetector, as a transducer for producing an output signal.

  8. Expressions for the precession quantities based upon the IAU /1976/ system of astronomical constants

    NASA Technical Reports Server (NTRS)

    Lieske, J. H.; Lederle, T.; Fricke, W.; Morando, B.

    1977-01-01

    The structure of the expressions usually employed in calculating the effects of precession is examined, and a method is outlined for revising the expressions to account for changes in the fundamental astronomical constants. It is shown that the basic set of parameters, upon which depend the lengthy polynomials for computing the mean obliquity of data and the elements of the precession matrix, consists of the mean obliquity, the speed of general precession in longitude at a fixed epoch, and the system of planetary masses. Special attention is given to the motion of the ecliptic pole, formulations for a basic epoch as well as an arbitrary epoch, and ecliptic motion relative to the basic epoch. Numerical precession quantities at epoch J2000.0 (JED 2451545.0) are presented which result from the revision of astronomical constants adopted at the XVI General Assembly of the IAU.

  9. Influence of a constant magnetic field on the fibrinogen-fibrin system. [in blood coagulation process

    NASA Technical Reports Server (NTRS)

    Matskevichene, V. B.; Platonova, A. T.

    1974-01-01

    The effect of a constant magnetic field with a strength of 2500 oersteds on the fibrinogen-fibrin system was studied in the organism of healthy rabbits with exposure times of 1 and 5 hours. The results obtained indicate disruptions in the stage of conversion of fibrinogen to fibrin and an increase in the amount of fibrinogen.

  10. 46 CFR 56.90-5 - Bolting procedure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Bolting procedure. 56.90-5 Section 56.90-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Assembly § 56.90-5 Bolting procedure. (a) All flanged joints shall be fitted up so that the gasket...

  11. 41 CFR 102-74.90 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false [Reserved] 102-74.90 Section 102-74.90 Public Contracts and Property Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 74-FACILITY MANAGEMENT Facility Management Concession...

  12. Simple and rapid quantification of serotonin transporter binding using [11C]DASB bolus plus constant infusion.

    PubMed

    Gryglewski, G; Rischka, L; Philippe, C; Hahn, A; James, G M; Klebermass, E; Hienert, M; Silberbauer, L; Vanicek, T; Kautzky, A; Berroterán-Infante, N; Nics, L; Traub-Weidinger, T; Mitterhauser, M; Wadsak, W; Hacker, M; Kasper, S; Lanzenberger, R

    2017-04-01

    In-vivo quantification of serotonin transporters (SERT) in human brain has been a mainstay of molecular imaging in the field of neuropsychiatric disorders and helped to explore the underpinnings of several medical conditions, therapeutic and environmental influences. The emergence of PET/MR hybrid systems and the heterogeneity of SERT binding call for the development of efficient methods making the investigation of larger or vulnerable populations with limited scanner time and simultaneous changes in molecular and functional measures possible. We propose [ 11 C]DASB bolus plus constant infusion for these applications and validate it against standard analyses of dynamic PET data. [ 11 C]DASB bolus/infusion optimization was performed on data acquired after [ 11 C]DASB bolus in 8 healthy subjects. Subsequently, 16 subjects underwent one scan using [ 11 C]DASB bolus plus constant infusion with K bol 160-179min and one scan after [ 11 C]DASB bolus for inter-method reliability analysis. Arterial blood sampling and metabolite analysis were performed for all scans. Distribution volumes (V T ) were obtained using Logan plots for bolus scans and ratios between tissue and plasma parent activity for bolus plus infusion scans for different time spans of the scan (V T-70 for 60-70min after start of tracer infusion, V T-90 for 75-90min, V T-120 for 100-120min) in 9 subjects. Omitting blood data, binding potentials (BP ND ) obtained using multilinear reference tissue modeling (MRTM2) and cerebellar gray matter as reference region were compared in 11 subjects. A K bol of 160min was observed to be optimal for rapid equilibration in thalamus and striatum. V T-70 showed good intraclass correlation coefficients (ICCs) of 0.61-0.70 for thalamus, striatal regions and olfactory cortex with bias ≤5.1% compared to bolus scans. ICCs increased to 0.72-0.78 for V T-90 and 0.77-0.93 for V T-120 in these regions. BP ND-90 had negligible bias ≤2.5%, low variability ≤7.9% and ICCs of 0

  13. 42 CFR 412.90 - General rules.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false General rules. 412.90 Section 412.90 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM PROSPECTIVE PAYMENT SYSTEMS FOR INPATIENT HOSPITAL SERVICES Special Treatment of Certain Facilities Under the...

  14. 47 CFR 90.677 - Reconfiguration of the 806-824/851-869 MHz band in order to separate cellular systems from non...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... relocation agreement. Sprint Nextel and relocating incumbents may agree to conduct face-to-face negotiations...-55. Sprint Nextel and relocating incumbents may agree to conduct face-to-face negotiations or either... in order to separate cellular systems from non-cellular systems. 90.677 Section 90.677...

  15. 47 CFR 90.761 - EA and Regional licenses.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Policies Governing the Licensing and Use of Phase II Ea, Regional and Nationwide Systems § 90.761 EA and Regional licenses. (a) EA licenses for spectrum blocks listed in Table 2 of § 90.721(b) are available in... 47 Telecommunication 5 2010-10-01 2010-10-01 false EA and Regional licenses. 90.761 Section 90.761...

  16. 47 CFR 90.761 - EA and Regional licenses.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Policies Governing the Licensing and Use of Phase II Ea, Regional and Nationwide Systems § 90.761 EA and Regional licenses. (a) EA licenses for spectrum blocks listed in Table 2 of § 90.721(b) are available in... 47 Telecommunication 5 2011-10-01 2011-10-01 false EA and Regional licenses. 90.761 Section 90.761...

  17. Mechanistic kinetic modeling generates system-independent P-glycoprotein mediated transport elementary rate constants for inhibition and, in combination with 3D SIM microscopy, elucidates the importance of microvilli morphology on P-glycoprotein mediated efflux activity.

    PubMed

    Ellens, Harma; Meng, Zhou; Le Marchand, Sylvain J; Bentz, Joe

    2018-06-01

    In vitro transporter kinetics are typically analyzed by steady-state Michaelis-Menten approximations. However, no clear evidence exists that these approximations, applied to multiple transporters in biological membranes, yield system-independent mechanistic parameters needed for reliable in vivo hypothesis generation and testing. Areas covered: The classical mass action model has been developed for P-glycoprotein (P-gp) mediated transport across confluent polarized cell monolayers. Numerical integration of the mass action equations for transport using a stable global optimization program yields fitted elementary rate constants that are system-independent. The efflux active P-gp was defined by the rate at which P-gp delivers drugs to the apical chamber, since as much as 90% of drugs effluxed by P-gp partition back into nearby microvilli prior to reaching the apical chamber. The efflux active P-gp concentration was 10-fold smaller than the total expressed P-gp for Caco-2 cells, due to their microvilli membrane morphology. The mechanistic insights from this analysis are readily extrapolated to P-gp mediated transport in vivo. Expert opinion: In vitro system-independent elementary rate constants for transporters are essential for the generation and validation of robust mechanistic PBPK models. Our modeling approach and programs have broad application potential. They can be used for any drug transporter with minor adaptations.

  18. 47 CFR 90.656 - Responsibilities of base station licensees of Specialized Mobile Radio systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Responsibilities of base station licensees of... Bands § 90.656 Responsibilities of base station licensees of Specialized Mobile Radio systems. (a) The licensees of base stations that provide Specialized Mobile Radio service on a commercial basis of the use of...

  19. 47 CFR 90.351 - Location and Monitoring Service.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Location and Monitoring Service. 90.351 Section 90.351 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Intelligent Transportation Systems Radio Service § 90.351...

  20. The Henry's constant of monochloramine.

    PubMed

    Garcia, Miguel A; Anderson, Michael A

    2018-02-01

    Monochloramine is a secondary disinfectant used in drinking water and is also formed in chlorinated wastewater. While known to hydrolyze over time and react with dissolved organic matter, its partitioning between the aqueous and gas phase has not been extensively studied. Preliminary experiments demonstrated that monochloramine concentrations in solutions open to the atmosphere or actively aerated decreased more rapidly than in sealed solutions, indicating significant losses to the atmosphere. For example, a monochloramine solution open to the atmosphere yielded a loss rate constant of 0.08 d -1 , a value twice that for sealed samples without headspace (0.04 d -1 ) where loss occurs exclusively as a result of hydrolysis. A solution aerated at 10 mL s -1 had a loss rate constant nearly 10× greater than that for hydrolysis alone (0.35 d -1 ). To better understand partitioning of monochloramine to the gas phase and potential for volatilization, the dimensionless Henry's law constants of monochloramine (K H ) were determined using an equilibrium headspace technique at five different temperatures (11, 16, 21, 27, and 32 °C). The resulting values ranged from 8 × 10 -3 to 4 × 10 -2 , indicating a semi-volatile compound, and were found to be consistent with quantitative structure activity relationship predictions. At 20 °C, monochloramine exhibits a dimensionless Henry's constant of about 1.7 × 10 -2 which is 35 times greater than ammonia but comparable to the Henry's constant of inorganic semi-volatile compounds such sulfur dioxide. The Henry's constant values for monochloramine suggests that volatilization could be a relevant loss process in open systems such as rivers receiving chlorinated wastewater effluent, swimming pools and cooling towers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Size- and temperature-dependent Hamaker constants for heterogeneous systems of interacting nanoparticles

    NASA Astrophysics Data System (ADS)

    Pinchuk, P.; Pinchuk, A. O.

    2016-09-01

    Hamaker-Lifshitz constants are used to calculate van der Waals interaction forces between small particles in solution. Typically, these constants are size-independent and material specific. According to the Lifshitz theory, the Hamaker-Lifshitz constants can be calculated by taking integrals that include the dielectric permittivity, as a function of frequency, of the interacting particles and the medium around particles. The dielectric permittivity of interacting metal nanoparticles can be calculated using the free-electron Drude model for metals. For bulk metals, the Drude model does is size independent. However, the conducting electrons in small metal nanoparticles exhibit surface scattering, which changes the complex dielectric permittivity function. Additionally, the Drude model can be modified to include temperature dependence. That is, an increase in temperature leads to thermal volume expansion and increased phonon population, which affect the scattering rate of the electrons and the plasma frequency. Both of these terms contribute significantly to the Drude model for the dielectric permittivity of the particles. In this work, we show theoretically that scattering of the free conducting electrons inside noble metal nanoparticles with the size of 1 - 50 nm leads to size-dependent dielectric permittivity and Hamaker-Lifshitz constants. In addition, we calculate numerically the Hamaker-Lifshitz constants for a variety of temperatures. The results of the study might be of interest for understanding colloidal stability of metal nanoparticles.

  2. Transient times in linear metabolic pathways under constant affinity constraints.

    PubMed

    Lloréns, M; Nuño, J C; Montero, F

    1997-10-15

    In the early seventies, Easterby began the analytical study of transition times for linear reaction schemes [Easterby (1973) Biochim. Biophys. Acta 293, 552-558]. In this pioneer work and in subsequent papers, a state function (the transient time) was used to measure the period before the stationary state, for systems constrained to work under both constant and variable input flux, was reached. Despite the undoubted usefulness of this quantity to describe the time-dependent features of these kinds of systems, its application to the study of chemical reactions under other constraints is questionable. In the present work, a generalization of these magnitudes to linear metabolic pathways functioning under a constant-affinity constraint is carried out. It is proved that classical definitions of transient times do not reflect the actual properties of the transition to the steady state in systems evolving under this restriction. Alternatively, a more adequate framework for interpretation of the transient times for systems with both constant and variable input flux is suggested. Within this context, new definitions that reflect more accurately the transient characteristics of constant affinity systems are stated. Finally, the meaning of these transient times is discussed.

  3. 47 CFR 90.763 - EA, Regional and nationwide system operations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... authorized pursuant to § 90.761 may construct and operate any number of land mobile or paging base stations... authorized pursuant to § 90.717(a) may construct and operate any number of land mobile or paging base stations, or fixed stations, anywhere in the Nation, and transmit on any of its authorized channels...

  4. 47 CFR 90.763 - EA, Regional and nationwide system operations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... authorized pursuant to § 90.761 may construct and operate any number of land mobile or paging base stations... authorized pursuant to § 90.717(a) may construct and operate any number of land mobile or paging base stations, or fixed stations, anywhere in the Nation, and transmit on any of its authorized channels...

  5. 47 CFR 90.763 - EA, Regional and nationwide system operations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... authorized pursuant to § 90.761 may construct and operate any number of land mobile or paging base stations... authorized pursuant to § 90.717(a) may construct and operate any number of land mobile or paging base stations, or fixed stations, anywhere in the Nation, and transmit on any of its authorized channels...

  6. Optimized constants for an ultraviolet light-adjustable intraocular lens.

    PubMed

    Conrad-Hengerer, Ina; Dick, H Burkhard; Hütz, Werner W; Haigis, Wolfgang; Hengerer, Fritz H

    2011-12-01

    To determine the accuracy of intraocular lens (IOL) power calculations and to suggest adjusted constants for implantation of ultraviolet light-adjustable IOLs. Center for Vision Science, Ruhr University Eye Clinic, Bochum, Germany. Cohort study. Eyes with a visually significant cataract that had phacoemulsification with implantation of a light-adjustable IOL were evaluated. IOLMaster measurements were performed before phacoemulsification and IOL implantation and 4 weeks after surgery before the first adjustment of the IOL. The difference in the expected refraction and estimation error was studied. The study evaluated 125 eyes. Using the surgical constants provided by the manufacturer of the light-adjustable IOL, the SRK/T formula gave a more hyperopic refraction than the Hoffer Q and Holladay 1 formulas. The mean error of prediction was 0.93 diopter (D) ± 0.69 (SD), 0.91 ± 0.63 D, and 0.86 ± 0.65 D, respectively. The corresponding mean absolute error of prediction was 0.98 ± 0.61 D, 0.93 ± 0.61 D, and 0.90 ± 0.59 D, respectively. With optimized constants for the formulas, the mean error of prediction was 0.00 ± 0.63 D for Hoffer Q, 0.00 ± 0.64 D for Holladay 1, and 0.00 ± 0.66 D for SRK/T. The expected refraction after phacoemulsification and implantation of a light-adjustable IOL toward the hyperopic side of the desired refraction could be considered when using the optimized constants for all formulas. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Constant fields and constant gradients in open ionic channels.

    PubMed Central

    Chen, D P; Barcilon, V; Eisenberg, R S

    1992-01-01

    Ions enter cells through pores in proteins that are holes in dielectrics. The energy of interaction between ion and charge induced on the dielectric is many kT, and so the dielectric properties of channel and pore are important. We describe ionic movement by (three-dimensional) Nemst-Planck equations (including flux and net charge). Potential is described by Poisson's equation in the pore and Laplace's equation in the channel wall, allowing induced but not permanent charge. Asymptotic expansions are constructed exploiting the long narrow shape of the pore and the relatively high dielectric constant of the pore's contents. The resulting one-dimensional equations can be integrated numerically; they can be analyzed when channels are short or long (compared with the Debye length). Traditional constant field equations are derived if the induced charge is small, e.g., if the channel is short or if the total concentration gradient is zero. A constant gradient of concentration is derived if the channel is long. Plots directly comparable to experiments are given of current vs voltage, reversal potential vs. concentration, and slope conductance vs. concentration. This dielectric theory can easily be tested: its parameters can be determined by traditional constant field measurements. The dielectric theory then predicts current-voltage relations quite different from constant field, usually more linear, when gradients of total concentration are imposed. Numerical analysis shows that the interaction of ion and channel can be described by a mean potential if, but only if, the induced charge is negligible, that is to say, the electric field is spatially constant. Images FIGURE 1 PMID:1376159

  8. Experimental investigation of a variable speed constant frequency electric generating system from a utility perspective

    NASA Technical Reports Server (NTRS)

    Herrera, J. I.; Reddoch, T. W.; Lawler, J. S.

    1985-01-01

    As efforts are accelerated to improve the overall capability and performance of wind electric systems, increased attention to variable speed configurations has developed. A number of potentially viable configurations have emerged. Various attributes of variable speed systems need to be carefully tested to evaluate their performance from the utility points of view. With this purpose, the NASA experimental variable speed constant frequency (VSCF) system has been tested. In order to determine the usefulness of these systems in utility applications, tests are required to resolve issues fundamental to electric utility systems. Legitimate questions exist regarding how variable speed generators will influence the performance of electric utility systems; therefore, tests from a utility perspective, have been performed on the VSCF system and an induction generator at an operating power level of 30 kW on a system rated at 200 kVA and 0.8 power factor.

  9. 48 CFR 3017.204-90 - Detention Facilities and Services (ICE).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 7 2011-10-01 2011-10-01 false Detention Facilities and Services (ICE). 3017.204-90 Section 3017.204-90 Federal Acquisition Regulations System DEPARTMENT OF... SPECIAL CONTRACTING METHODS Options. 3017.204-90 Detention Facilities and Services (ICE). The ICE Head of...

  10. 48 CFR 3017.204-90 - Detention Facilities and Services (ICE).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 7 2013-10-01 2012-10-01 true Detention Facilities and Services (ICE). 3017.204-90 Section 3017.204-90 Federal Acquisition Regulations System DEPARTMENT OF... SPECIAL CONTRACTING METHODS Options 3017.204-90 Detention Facilities and Services (ICE). The ICE Head of...

  11. 48 CFR 3017.204-90 - Detention Facilities and Services (ICE).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Detention Facilities and Services (ICE). 3017.204-90 Section 3017.204-90 Federal Acquisition Regulations System DEPARTMENT OF... SPECIAL CONTRACTING METHODS Options. 3017.204-90 Detention Facilities and Services (ICE). The ICE Head of...

  12. 48 CFR 3017.204-90 - Detention Facilities and Services (ICE).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 7 2014-10-01 2014-10-01 false Detention Facilities and Services (ICE). 3017.204-90 Section 3017.204-90 Federal Acquisition Regulations System DEPARTMENT OF... SPECIAL CONTRACTING METHODS Options 3017.204-90 Detention Facilities and Services (ICE). The ICE Head of...

  13. 48 CFR 3017.204-90 - Detention Facilities and Services (ICE).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 7 2012-10-01 2012-10-01 false Detention Facilities and Services (ICE). 3017.204-90 Section 3017.204-90 Federal Acquisition Regulations System DEPARTMENT OF... SPECIAL CONTRACTING METHODS Options 3017.204-90 Detention Facilities and Services (ICE). The ICE Head of...

  14. 40 CFR 90.412 - Data logging.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Data logging. 90.412 Section 90.412....412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection...

  15. 40 CFR 90.412 - Data logging.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Data logging. 90.412 Section 90.412....412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection...

  16. 40 CFR 90.412 - Data logging.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Data logging. 90.412 Section 90.412....412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection...

  17. 40 CFR 90.412 - Data logging.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Data logging. 90.412 Section 90.412....412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection...

  18. 40 CFR 90.412 - Data logging.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Data logging. 90.412 Section 90.412....412 Data logging. (a) A computer or any other automatic data collection (ADC) device(s) may be used as long as the system meets the requirements of this subpart. (b) Determine from the data collection...

  19. Bipolar square-wave current source for transient electromagnetic systems based on constant shutdown time

    NASA Astrophysics Data System (ADS)

    Wang, Shilong; Yin, Changchun; Lin, Jun; Yang, Yu; Hu, Xueyan

    2016-03-01

    Cooperative work of multiple magnetic transmitting sources is a new trend in the development of transient electromagnetic system. The key is the bipolar current waves shutdown, concurrently in the inductive load. In the past, it was difficult to use the constant clamping voltage technique to realize the synchronized shutdown of currents with different peak values. Based on clamping voltage technique, we introduce a new controlling method with constant shutdown time. We use the rising time to control shutdown time and use low voltage power source to control peak current. From the viewpoint of the circuit energy loss, by taking the high-voltage capacitor bypass resistance and the capacitor of the passive snubber circuit into account, we establish the relationship between the rising time and the shutdown time. Since the switch is not ideal, we propose a new method to test the shutdown time by the low voltage, the high voltage and the peak current. Experimental results show that adjustment of the current rising time can precisely control the value of the clamp voltage. When the rising time is fixed, the shutdown time is unchanged. The error for shutdown time deduced from the energy consumption is less than 6%. The new controlling method on current shutdown proposed in this paper can be used in the cooperative work of borehole and ground transmitting system.

  20. Bipolar square-wave current source for transient electromagnetic systems based on constant shutdown time.

    PubMed

    Wang, Shilong; Yin, Changchun; Lin, Jun; Yang, Yu; Hu, Xueyan

    2016-03-01

    Cooperative work of multiple magnetic transmitting sources is a new trend in the development of transient electromagnetic system. The key is the bipolar current waves shutdown, concurrently in the inductive load. In the past, it was difficult to use the constant clamping voltage technique to realize the synchronized shutdown of currents with different peak values. Based on clamping voltage technique, we introduce a new controlling method with constant shutdown time. We use the rising time to control shutdown time and use low voltage power source to control peak current. From the viewpoint of the circuit energy loss, by taking the high-voltage capacitor bypass resistance and the capacitor of the passive snubber circuit into account, we establish the relationship between the rising time and the shutdown time. Since the switch is not ideal, we propose a new method to test the shutdown time by the low voltage, the high voltage and the peak current. Experimental results show that adjustment of the current rising time can precisely control the value of the clamp voltage. When the rising time is fixed, the shutdown time is unchanged. The error for shutdown time deduced from the energy consumption is less than 6%. The new controlling method on current shutdown proposed in this paper can be used in the cooperative work of borehole and ground transmitting system.

  1. A 90GHz Bolometer Camera Detector System for the Green Bank Telescope

    NASA Technical Reports Server (NTRS)

    Benford, Dominic J.; Allen, Christine A.; Buchanan, Ernest D.; Chen, Tina C.; Chervenak, James A.; Devlin, Mark J.; Dicker, Simon R.; Forgione, Joshua B.

    2004-01-01

    We describe a close-packed, two-dimensional imaging detector system for operation at 90GHz (3.3mm) for the 100 m Green Bank Telescope (GBT) This system will provide high sensitivity (<1mjy in 1s rapid imaging (15'x15' to 250 microJy in 1 hr) at the world's largest steerable aperture. The heart of this camera is an 8x8 close packed, Nyquist-sampled array of superconducting transition edge sensor bolometers. We have designed and are producing a functional superconducting bolometer array system using a monolithic planar architecture and high-speed multiplexed readout electronics. With an NEP of approx. 2.10(exp 17) W/square root Hz, the TES bolometers will provide fast linear sensitive response for high performance imaging. The detectors are read out by and 8x8 time domain SQUID multiplexer. A digital/analog electronics system has been designed to enable read out by SQUID multiplexers. First light for this instrument on the GBT is expected within a year.

  2. Constant pressure mode extended simple gradient liquid chromatography system for micro and nanocolumns.

    PubMed

    Šesták, Jozef; Kahle, Vladislav

    2014-07-11

    Performing gradient liquid chromatography at constant pressure instead of constant flow rate has serious potential for shortening the analysis time and increasing the productivity of HPLC instruments that use gradient methods. However, in the constant pressure mode the decreasing column permeability during a long period of time negatively affects the repeatability of retention time. Thus a volume-based approach, in which the detector signal is plotted as a function of retention volume, must be taken into consideration. Traditional HPLC equipment, however, requires quite complex hardware and software modifications in order to work at constant pressure and in the volume-based mode. In this short communication, a low cost and easily feasible pressure-controlled extension of the previously described simple gradient liquid chromatography platform is proposed. A test mixture of four nitro esters was separated by 10-60% (v/v) acetone/water gradient and a high repeatability of retention volumes at 20MPa (RSD less than 0.45%) was realized. Separations were also performed at different values of pressure (20, 25, and 31MPa), and only small variations of the retention volumes (up to 0.8%) were observed. In this particular case, the gain in the analysis speed of 7% compared to the constant flow mode was realized at a constant pressure. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Cosmological variation of the MOND constant: Secular effects on galactic systems

    NASA Astrophysics Data System (ADS)

    Milgrom, Mordehai

    2015-02-01

    The proximity of the MOND acceleration constant with cosmological accelerations—for example, a0≈c H0/2 π —points to its possibly decreasing with cosmic time. I begin to consider the secular changes induced in galactic systems by such presumed variations, which are assumed to be adiabatic. It is important to understand these effects, in isolation from other evolutionary influences, in order to identify or constrain a0 variations by detection of induced effects, or lack thereof. I find that as long as the system is fully in the deep-MOND regime—as applies to many galactic systems—the adiabatic response of the system obeys simple scaling laws. For example, in a system that would be stationary for fixed a0, the system expands homologously as a0-1 /4, while internal velocities decrease uniformly as a01 /4. If a0∝c H at all relevant times, this change amounts to a factor of ˜2.5 since redshift 10. For rotating systems, the angular frequency Ω ∝a01 /2. The accelerations increase relative to a0 as a0-1 /4, pushing the system towards the Newtonian regime. All this follows from the appearance of a0 in MOND and the scale invariance of the deep-MOND limit—two basic tenets of MOND. More complicated evolution ensues when parts of the system become Newtonian, or are so from inception. For example, these parts may become unstable since they are not protected by MOND's stabilizing effects. The existence of such regions also modifies the MONDian regime since they affect the potential everywhere, and constituents might migrate between the Newtonian and MONDian regimes. Studying these last effects would require detailed numerical calculations.

  4. 40 CFR 90.314 - Analyzer accuracy and specifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... engineering practice. Adhere to the minimum requirements given in §§ 90.316 through 90.325 and § 90.409. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates that exhaust emission...) Some high resolution read-out systems, such as computers, data loggers, and so forth, can provide...

  5. 40 CFR 90.314 - Analyzer accuracy and specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... engineering practice. Adhere to the minimum requirements given in §§ 90.316 through 90.325 and § 90.409. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates that exhaust emission...) Some high resolution read-out systems, such as computers, data loggers, and so forth, can provide...

  6. 40 CFR 90.314 - Analyzer accuracy and specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... engineering practice. Adhere to the minimum requirements given in §§ 90.316 through 90.325 and § 90.409. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates that exhaust emission...) Some high resolution read-out systems, such as computers, data loggers, and so forth, can provide...

  7. 40 CFR 90.314 - Analyzer accuracy and specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... engineering practice. Adhere to the minimum requirements given in §§ 90.316 through 90.325 and § 90.409. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates that exhaust emission...) Some high resolution read-out systems, such as computers, data loggers, and so forth, can provide...

  8. 47 CFR 90.723 - Selection and assignment of frequencies.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Selection and assignment of frequencies. 90.723... 220-222 MHz Band § 90.723 Selection and assignment of frequencies. (a) Phase II applications for... systems, 10-channel EA systems, 15-channel Regional systems, public safety/mutual aid use, or emergency...

  9. Optimal trace inequality constants for interior penalty discontinuous Galerkin discretisations of elliptic operators using arbitrary elements with non-constant Jacobians

    NASA Astrophysics Data System (ADS)

    Owens, A. R.; Kópházi, J.; Eaton, M. D.

    2017-12-01

    In this paper, a new method to numerically calculate the trace inequality constants, which arise in the calculation of penalty parameters for interior penalty discretisations of elliptic operators, is presented. These constants are provably optimal for the inequality of interest. As their calculation is based on the solution of a generalised eigenvalue problem involving the volumetric and face stiffness matrices, the method is applicable to any element type for which these matrices can be calculated, including standard finite elements and the non-uniform rational B-splines of isogeometric analysis. In particular, the presented method does not require the Jacobian of the element to be constant, and so can be applied to a much wider variety of element shapes than are currently available in the literature. Numerical results are presented for a variety of finite element and isogeometric cases. When the Jacobian is constant, it is demonstrated that the new method produces lower penalty parameters than existing methods in the literature in all cases, which translates directly into savings in the solution time of the resulting linear system. When the Jacobian is not constant, it is shown that the naive application of existing approaches can result in penalty parameters that do not guarantee coercivity of the bilinear form, and by extension, the stability of the solution. The method of manufactured solutions is applied to a model reaction-diffusion equation with a range of parameters, and it is found that using penalty parameters based on the new trace inequality constants result in better conditioned linear systems, which can be solved approximately 11% faster than those produced by the methods from the literature.

  10. Determination of the Boltzmann constant by dielectric-constant gas thermometry

    NASA Astrophysics Data System (ADS)

    Fellmuth, Bernd; Fischer, Joachim; Gaiser, Christof; Jusko, Otto; Priruenrom, Tasanee; Sabuga, Wladimir; Zandt, Thorsten

    2011-10-01

    Within an international project directed to the new definition of the base unit kelvin, the Boltzmann constant k has been determined by dielectric-constant gas thermometry at PTB. In the pressure range from about 1 MPa to 7 MPa, 11 helium isotherms have been measured at the triple point of water (TPW) by applying a new special experimental setup consisting of a large-volume thermostat, a vacuum-isolated measuring system, stainless-steel 10 pF cylindrical capacitors, an autotransformer ratio capacitance bridge, a high-purity gas-handling system including a mass spectrometer, and traceably calibrated special pressure balances with piston-cylinder assemblies having effective areas of 2 cm2. The value of k has been deduced from the linear, ideal-gas term of an appropriate virial expansion fitted to the combined isotherms. A detailed uncertainty budget has been established by performing Monte Carlo simulations. The main uncertainty components result from the measurement of pressure and capacitance as well as the influence of the effective compressibility of the measuring capacitor and impurities contained in the helium gas. The combination of the results obtained at the TPW (kTPW = 1.380 654 × 10-23 J K-1, relative standard uncertainty 9.2 parts per million) with data measured earlier at low temperatures (21 K to 27 K, kLT = 1.380 657 × 10-23 J K-1, 15.9 parts per million) has yielded a value of k = 1.380 655 × 10-23 J K-1 with uncertainty of 7.9 parts per million.

  11. 47 CFR 90.629 - Extended implementation period.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Extended implementation period. 90.629 Section... 935-940 Mhz Bands § 90.629 Extended implementation period. Applicants requesting frequencies for... an extended implementation period. The justification must describe the proposed system, state the...

  12. 47 CFR 90.629 - Extended implementation period.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Extended implementation period. 90.629 Section... 935-940 Mhz Bands § 90.629 Extended implementation period. Applicants requesting frequencies for... an extended implementation period. The justification must describe the proposed system, state the...

  13. 47 CFR 90.629 - Extended implementation period.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Extended implementation period. 90.629 Section... 935-940 Mhz Bands § 90.629 Extended implementation period. Applicants requesting frequencies for... an extended implementation period. The justification must describe the proposed system, state the...

  14. 47 CFR 90.629 - Extended implementation period.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Extended implementation period. 90.629 Section... 935-940 Mhz Bands § 90.629 Extended implementation period. Applicants requesting frequencies for... an extended implementation period. The justification must describe the proposed system, state the...

  15. 47 CFR 90.629 - Extended implementation period.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Extended implementation period. 90.629 Section... 935-940 Mhz Bands § 90.629 Extended implementation period. Applicants requesting frequencies for... an extended implementation period. The justification must describe the proposed system, state the...

  16. Systems with a constant heat flux with applications to radiative heat transport across nanoscale gaps and layers

    NASA Astrophysics Data System (ADS)

    Budaev, Bair V.; Bogy, David B.

    2018-06-01

    We extend the statistical analysis of equilibrium systems to systems with a constant heat flux. This extension leads to natural generalizations of Maxwell-Boltzmann's and Planck's equilibrium energy distributions to energy distributions of systems with a net heat flux. This development provides a long needed foundation for addressing problems of nanoscale heat transport by a systematic method based on a few fundamental principles. As an example, we consider the computation of the radiative heat flux between narrowly spaced half-spaces maintained at different temperatures.

  17. 47 CFR 90.219 - Use of signal boosters.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... fill in only weak signal areas and cannot extend the system's normal signal coverage area. (b) Class A... 47 Telecommunication 5 2010-10-01 2010-10-01 false Use of signal boosters. 90.219 Section 90.219... MOBILE RADIO SERVICES General Technical Standards § 90.219 Use of signal boosters. Licensees authorized...

  18. 47 CFR 90.219 - Use of signal boosters.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... fill in only weak signal areas and cannot extend the system's normal signal coverage area. (b) Class A... 47 Telecommunication 5 2011-10-01 2011-10-01 false Use of signal boosters. 90.219 Section 90.219... MOBILE RADIO SERVICES General Technical Standards § 90.219 Use of signal boosters. Licensees authorized...

  19. 47 CFR 90.219 - Use of signal boosters.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... fill in only weak signal areas and cannot extend the system's normal signal coverage area. (b) Class A... 47 Telecommunication 5 2012-10-01 2012-10-01 false Use of signal boosters. 90.219 Section 90.219... MOBILE RADIO SERVICES General Technical Standards § 90.219 Use of signal boosters. Licensees authorized...

  20. The hubble constant.

    PubMed

    Huchra, J P

    1992-04-17

    The Hubble constant is the constant of proportionality between recession velocity and distance in the expanding universe. It is a fundamental property of cosmology that sets both the scale and the expansion age of the universe. It is determined by measurement of galaxy The Hubble constant is the constant of proportionality between recession velocity and development of new techniques for the measurements of galaxy distances, both calibration uncertainties and debates over systematic errors remain. Current determinations still range over nearly a factor of 2; the higher values favored by most local measurements are not consistent with many theories of the origin of large-scale structure and stellar evolution.

  1. The Planck Constant, the International System of Units, and the 2012 North American Watt Balance Absolute Gravity Comparison

    NASA Astrophysics Data System (ADS)

    Newell, D. B.

    2012-12-01

    As outlined in Resolution 1 of the 24th Meeting of the General Conference on Weights and Measures (CGPM) on the future revision of the International System of Units (SI) [1], the current four SI base units the kilogram, the ampere, the kelvin and the mole, will be redefined in terms of invariants of nature. The new definitions will be based on fixed numerical values of the Planck constant (h), the elementary charge (e), the Boltzmann constant (k), and the Avogadro constant (NA), respectively. While significant progress has been made towards providing the necessary experimental results for the redefinition, some disagreement among the relevant data remain. Among the set of discrepant data towards the redefinition of the SI are the determinations of the Planck constant from the National Institute of Standards and Technology (NIST) watt balance [2] and the recent result from the National Research Council Canada (NRC) watt balance [3], with the discrepancy of roughly 2.5 parts in 107 being significantly outside the reported uncertainties. Of major concern is that the watt balance experiment is seen as a key component of a mise en pratique for the new kilogram definition, once such a redefinition takes place. The basic operational principle of a watt balance relates the Planck constant to mass, length, and time through h = mgvC, where m is the mass of an artifact mass standard, g is the local acceleration of gravity, v is a velocity, and C is a combination of frequencies and scalar constants. With the total uncertainty goal for the watt balance on the order of a few parts in 108, g needs to be determined at the location of the mass standard to parts in 109 such that its uncertainty is negligible in the final watt balance result. NIST and NRC have formed a collaborative effort to reconcile the relevant discrepant data and provide further progress towards preparing and testing a mise en pratique for the new kilogram definition. As an initial step, direct comparisons of

  2. Sweden, the first country to achieve the Joint United Nations Programme on HIV/AIDS (UNAIDS)/World Health Organization (WHO) 90-90-90 continuum of HIV care targets.

    PubMed

    Gisslén, M; Svedhem, V; Lindborg, L; Flamholc, L; Norrgren, H; Wendahl, S; Axelsson, M; Sönnerborg, A

    2017-04-01

    The Joint United Nations Programme on HIV/AIDS (UNAIDS)/World Health Organization (WHO) 90-90-90 goals propose that 90% of all people living with HIV should know their HIV status, 90% of those diagnosed should receive antiretroviral therapy (ART), and 90% of those should have durable viral suppression. We have estimated the continuum of HIV care for the entire HIV-1-infected population in Sweden. The Swedish InfCare HIV Cohort Study collects viral loads, CD4 counts, and viral sequences, along with demographic and clinical data, through an electronic clinical decision support system. Almost 100% of those diagnosed with HIV infection are included in the database, corresponding to 6946 diagnosed subjects living with HIV-1 in Sweden by 31 December 2015. Using HIV surveillance data reported to the Public Health Agency of Sweden, it was estimated that 10% of all HIV-infected subjects in Sweden remain undiagnosed. Among all diagnosed patients, 99.8% were linked to care and 97.1% of those remained in care. On 31 December 2015, 6605 of 6946 patients (95.1%) were on ART. A total of 6395 had been on treatment for at least 6 months and 6053 of those (94.7%) had a viral load < 50 HIV-1 RNA copies/mL. The 2014 UNAIDS/WHO 90-90-90 goals for HIV care means that > 73% of all patients living with HIV should be virologically suppressed by 2020. Sweden has already achieved this target, with 78% suppression, and is the first country reported to meet all the UNAIDS/WHO 90-90-90 goals. © 2016 The Authors. HIV Medicine published by John Wiley & Sons Ltd on behalf of British HIV Association.

  3. Convection currents enhancement of the spring constant in optical tweezers

    NASA Astrophysics Data System (ADS)

    Zenteno-Hernández, J. A.; Gómez-Vieyra, A.; Torres-Hurtado, S. A.; Ramirez-San-Juan, J. C.; Ramos-García, R.

    2016-09-01

    In this work we demonstrate the increasing of the trap stiffness (spring constant) constant of an optical trap of particles suspended in water by laser-induced convection currents. These currents are the result of thermal gradients created by a light absorption in a thin layer of hydrogenated amorphous silicon (a:Si-H) deposited at the bottom of cell. Since convection currents (and therefore drag forces) are symmetric around the beam focus particles trapped by the beam are further contained. Around the focus the drag force is directed upwards and partially compensated by radiation pressure depending on the laser power increasing the stiffness of the optical trapping increases significatively so a particle trapped could dragged (by moving the translation stage leaving the beam fixed) at velocities as high as 90μm/s without escaping the trap, whereas with no a:Si-H film, the particle escapes from the trap at lower velocities (30μm/s).

  4. Evaluation of a Perforated Drug Delivery System in Mice for Prolonged and Constant Release of a Hydrophilic Drug

    DTIC Science & Technology

    2012-02-17

    A drug delivery system (DDS) consisting of a perforated microtube ( polyimide , inside diameter= 1.8 mm, tube length= 20 mm, hole size= 0.15 mm) was... biocompatible and capable of long-term constant release of hydrophilic drugs such as sodium fluorescein.

  5. Diurnal rhythm of the pituitary-adrenocortical response to stress: effect of constant light and constant darkness

    NASA Technical Reports Server (NTRS)

    Vernikos-Danellis, J.; Winget, C. M.; Hetherington, N. W.

    1970-01-01

    The existence of a biological rhythm in the response of animals to noxious stimuli and drugs is well known. However, the mechanism of this response is not well understood. This study was undertaken to describe the existence of a diurnal rhythm in the hypothalamic-pituitary-adrenocortical system before and after stress in female rats kept in controlled environmental conditions in 12L:12D, 24L:OD, or OL:24D. Plasma ACTH and plasma corticosterone concentrations were compared in unstressed animals. The time pattern in the response to stress was determined at four hourly intervals during a 24 hr period in which plasma ACTH and plasma corticosterone were measured at different time intervals. The stress response varied considerably with time of day in both magnitude and duration. The adrenals of rats exposed to constant light for 45 days atrophied, whereas the adrenals of animals kept in constant dark for the same period did not differ significantly from those of controls kept in 12L:12D. The increase in plasma ACTH in response to stress was greater both in the animals maintained in constant light and in constant dark than in the 12L:12D controls. Homeostatic mechanisms involved in these changes are discussed.

  6. Design and simulation of maximum power point tracking (MPPT) system on solar module system using constant voltage (CV) method

    NASA Astrophysics Data System (ADS)

    Bhatara, Sevty Satria; Iskandar, Reza Fauzi; Kirom, M. Ramdlan

    2016-02-01

    Solar energy is one of renewable energy resource where needs a photovoltaic module to convert it into electrical energy. One of the problems on solar energy conversion is the process of battery charging. To improve efficiency of energy conversion, PV system needs another control method on battery charging called maximum power point tracking (MPPT). This paper report the study on charging optimation using constant voltage (CV) method. This method has a function of determining output voltage of the PV system on maximal condition, so PV system will always produce a maximal energy. A model represented a PV system with and without MPPT was developed using Simulink. PV system simulation showed a different outcome energy when different solar radiation and numbers of solar module were applied in the model. On the simulation of solar radiation 1000 W/m2, PV system with MPPT produces 252.66 Watt energy and PV system without MPPT produces 252.66 Watt energy. The larger the solar radiation, the greater the energy of PV modules was produced.

  7. The Value of ABCD2F Scoring System (ABCD2 Combined with Atrial Fibrillation) to Predict 90-Day Recurrent Brain Stroke

    PubMed Central

    Almasi, Mostafa; Ghasemi, Faeze; Chardoli, Mojtaba

    2016-01-01

    Background. The ABCD2 score is now identified as a useful clinical prediction rule to determine the risk for stroke in the days following brain ischemic attacks. Aim. The present study aimed to introduce a new scoring system named “ABCD2F” and compare its value with the previous ABCD2 system to predict recurrent ischemic stroke within 90 days of the initial cerebrovascular accident (CVA). Methods. 138 consecutive patients with the final diagnosis of ischemic CVA or TIAs who referred to emergency ward of Rasoul-e-Akram general hospital in Tehran from September 2012 to December 2013 were eligible. By adding a new score in the presence of atrial fibrillation to ABCD2 system, the new scoring system as ABCD2F was introduced and the risk stratification was done again on this new system. Results. The area under the curve for ABCD2 was 0.434 and for ABCD2F it was 0.452 indicating low value of both systems for assessing recurrence of stroke within 90 days of primary event. Multivariable logistic regression analysis showed that none of the baseline factors could predict 90-day recurrent stroke. Conclusion. ABCD2 and/or atrial fibrillation are not good scoring candidates for assessing the risk of recurrent stroke within first 90 days. PMID:27642521

  8. Calculating Equilibrium Constants in the SnCl2-H2O-NaOH System According to Potentiometric Titration Data

    NASA Astrophysics Data System (ADS)

    Maskaeva, L. N.; Fedorova, E. A.; Yusupov, R. A.; Markov, V. F.

    2018-05-01

    The potentiometric titration of tin chloride SnCl2 is performed in the concentration range of 0.00009-1.1 mol/L with a solution of sodium hydroxide NaOH. According to potentiometric titration data based on modeling equilibria in the SnCl2-H2O-NaOH system, basic equations are generated for the main processes, and instability constants are calculated for the resulting hydroxo complexes and equilibrium constants of low-soluble tin(II) compounds. The data will be of interest for specialists in the field of theory of solutions.

  9. KSC-pa90-04

    NASA Image and Video Library

    1998-05-03

    KENNEDY SPACE CENTER, FLA. -- The orbiter Columbia is moments from touchdown on Runway 33 of KSC's Shuttle Landing Facility to complete the nearly 16-day STS-90 mission. Main gear touchdown was at 12:08:59 p.m. EDT on May 3, 1998, landing on orbit 256 of the mission. The wheels stopped at 12:09:58 EDT, completing a total mission time of 15 days, 21 hours, 50 minutes and 58 seconds. The 90th Shuttle mission was Columbia's 13th landing at the space center and the 43rd KSC landing in the history of the Space Shuttle program. During the mission, the crew conducted research to contribute to a better understanding of the human nervous system. The crew of the STS-90 Neurolab mission include Commander Richard Searfoss; Pilot Scott Altman; Mission Specialists Richard Linnehan, D.V.M., Dafydd (Dave) Williams, M.D., with the Canadian Space Agency, and Kathryn (Kay) Hire; and Payload Specialists Jay Buckey, M.D., and James Pawelczyk, Ph.D

  10. Comparison between variable and constant rotor speed operation on WINDMEL-II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sasamoto, Akira; Matsumiya, Hikaru; Kawamura, Shunji

    1996-10-01

    On a wind turbine control system for rotor revolution speed, it is believed that variable speed operation has the advantages over constant speed from a view point of both aerodynamics and mechanics. However, there is no experimental study which shows the differences. In this report, the authors intend to clarify the differences about shaft torque by using experimental data, from a new wind turbine system which has both variable and constant operation. The result in observation of the experimental data shows that variable speed operational shaft torque is lower than constant speed operational one.

  11. Preparation & in vitro evaluation of 90Y-DOTA-rituximab

    PubMed Central

    Kameswaran, Mythili; Pandey, Usha; Dash, Ashutosh; Samuel, Grace; Venkatesh, Meera

    2016-01-01

    Background & objectives: Radioimmunotherapy is extensively being used for the treatment of non-Hodgkin's lymphoma (NHL). Use of rituximab, a chimeric anti-CD20 antibody directed against the CD20 antigen in combination with suitable beta emitters is expected to result in good treatment response by its cross-fire and bystander effects. The present work involves the conjugation of p-isothiocyanatobenzyl DOTA (p-SCN-Bn-DOTA) to rituximab, its radiolabelling with 90Y and in vitro and in vivo evaluation to determine its potential as a radioimmunotherapeutic agent. Methods: Rituximab was conjugated with p-SCN-Bn-DOTA at 1:1 antibody: DOTA molar ratio. The number of DOTA molecules linked to one molecule of rituximab was determined by radioassay and spectroscopic assay. Radiolabelling of rituximab with 90Y was carried out and its in vitro stability was evaluated. In vitro cell binding studies were carried out in Raji cells expressing CD20 antigen. Biodistribution studies were carried out in normal Swiss mice. Results: Using both radioassay and spectroscopic method, it was determined that about five molecules of DOTA were linked to rituximab. Radiolabelling of the rituximab conjugate with 90Y and subsequent purification on PD-10 column gave a product with radiochemical purity (RCP) > 98 per cent which was retained at > 90 per cent up to 72 h when stored at 37°C. In vitro cell binding experiments of 90Y-DOTA-rituximab with Raji cells exhibited specific binding of 20.7 ± 0.1 per cent with 90Y-DOTA-rituximab which reduced to 15.5 ± 0.2 per cent when incubated with cold rituximab. The equilibrium constant Kd for 90Y-DOTA-Rituximab was determined to be 3.38 nM. Radiolabelled antibody showed clearance via hepatobiliary and renal routes and activity in tibia was found to be quite low indicating in vivo stability of 90Y-DOTA-rituximab. Interpretation & conclusions: p-SCN-Bn-DOTA was conjugated with rituximab and radiolabelling with 90Y was carried out. In vitro studies carried

  12. Epidemiological impact of achieving UNAIDS 90-90-90 targets for HIV care in India: a modelling study.

    PubMed

    Maddali, Manoj V; Gupta, Amita; Shah, Maunank

    2016-07-07

    Recent UNAIDS '90-90-90' targets propose that to end the HIV epidemic by 2030, 90% of persons living with HIV (PLWH) worldwide should know their diagnosis, 90% of diagnosed PLWH should be on antiretroviral therapy (ART) and 90% of PLWH on ART should be virally suppressed by 2020. We sought to quantify the epidemiological impact of achieving these targets in India. We constructed a dynamic-transmission model of the Indian HIV epidemic to project HIV infections and AIDS-related deaths that would occur in India over 15 years. We considered several scenarios: continuation of current care engagement (with early ART initiation), achieving 90-90-90 targets on time and delaying achievement by 5 or 10 years. In the base case, assuming continuation of current care engagement, we project 794 000 (95% uncertainty range (UR) 571 000-1 104 000) HIV infections and 689 000 (95% UR 468 000-976 000) AIDS-related deaths in India over 15 years. In this scenario, nearly half of PLWH diagnosed would fail to achieve viral suppression by 2030. With achievement of 90-90-90 targets, India could avert 392 000 (95% UR 248 000-559 000) transmissions (48% reduction) and 414 000 (95% UR 260 000-598 000) AIDS-related deaths (59% reduction) compared to the base-case scenario. Furthermore, fewer than 20 000 (95% UR 12 000-30 000) HIV infections would occur in 2030. Delaying achievement of targets resulted in a similar reduction in HIV incidence by 2030 but at the cost of excess overall infections and mortality. India can halve the epidemiological burden of HIV over 15 years with achievement of the UNAIDS 90-90-90 targets. Reaching the targets on time will require comprehensive healthcare strengthening, especially in early diagnosis and treatment, expanded access to second-line and third-line ART and long-term retention in care. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. Effects of system net charge and electrostatic truncation on all-atom constant pH molecular dynamics.

    PubMed

    Chen, Wei; Shen, Jana K

    2014-10-15

    Constant pH molecular dynamics offers a means to rigorously study the effects of solution pH on dynamical processes. Here, we address two critical questions arising from the most recent developments of the all-atom continuous constant pH molecular dynamics (CpHMD) method: (1) What is the effect of spatial electrostatic truncation on the sampling of protonation states? (2) Is the enforcement of electrical neutrality necessary for constant pH simulations? We first examined how the generalized reaction field and force-shifting schemes modify the electrostatic forces on the titration coordinates. Free energy simulations of model compounds were then carried out to delineate the errors in the deprotonation free energy and salt-bridge stability due to electrostatic truncation and system net charge. Finally, CpHMD titration of a mini-protein HP36 was used to understand the manifestation of the two types of errors in the calculated pK(a) values. The major finding is that enforcing charge neutrality under all pH conditions and at all time via cotitrating ions significantly improves the accuracy of protonation-state sampling. We suggest that such finding is also relevant for simulations with particle mesh Ewald, considering the known artifacts due to charge-compensating background plasma. Copyright © 2014 Wiley Periodicals, Inc.

  14. Constant envelope OFDM scheme for 6PolSK-QPSK

    NASA Astrophysics Data System (ADS)

    Li, Yupeng; Ding, Ding

    2018-03-01

    A constant envelope OFDM scheme with phase modulator (PM-CE-OFDM) for 6PolSK-QPSK modulation was demonstrated. Performance under large fiber launch power is measured to check its advantages in counteracting fiber nonlinear impairments. In our simulation, PM-CE-OFDM, RF-assisted constant envelope OFDM (RF-CE-OFDM) and conventional OFDM (Con-OFDM) are transmitted through 80 km standard single mode fiber (SSMF) single channel and WDM system. Simulation results confirm that PM-CE-OFDM has best performance in resisting fiber nonlinearity. In addition, benefiting from the simple system structure, the complexity and cost of PM-CE-OFDM system could be reduced effectively.

  15. 75 FR 80370 - Airworthiness Directives; General Electric Company GE90-76B; GE90-77B; GE90-85B; GE90-90B; and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-22

    ... repetitive fluorescent penetrant inspections (FPIs) and eddy current inspections (ECIs) of the high-pressure... high- pressure compressor rotor (HPCR) 8-10 stage spool, part number (P/N) 1844M90G01 or 1844M90G02...

  16. SU-F-T-344: Commissioning Constant Dose Rate VMAT in the Raystation Treatment Planning System for a Varian Clinac IX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pursley, J; Gueorguiev, G; Prichard, H

    Purpose: To demonstrate the commissioning of constant dose rate volumetric modulated arc therapy (VMAT) in the Raystation treatment planning system for a Varian Clinac iX with Exact couch. Methods: Constant dose rate (CDR) VMAT is an option in the Raystation treatment planning system, enabling VMAT delivery on Varian linacs without a RapidArc upgrade. Raystation 4.7 was used to commission CDR-VMAT for a Varian Clinac iX. Raystation arc model parameters were selected to match machine deliverability characteristics. A Varian Exact couch model was added to Raystation 4.7 and commissioned for use in VMAT optimization. CDR-VMAT commissioning checks were performed on themore » linac, including patient-specific QA measurements for 10 test patients using both the ArcCHECK from Sun Nuclear Corporation and COMPASS from IBA Dosimetry. Multi-criteria optimization (MCO) in Raystation was used for CDR-VMAT planning. Results: Raystation 4.7 generated clinically acceptable and deliverable CDR-VMAT plans for the Varian Clinac. VMAT plans were optimized including a model of the Exact couch with both rails in the out positions. CDR-VMAT plans generated with MCO in Raystation were dosimetrically comparable to Raystation MCO-generated IMRT plans. Patient-specific QA measurements with the ArcCHECK on the couch showed good agreement with the treatment planning system prediction. Patient-specific, structure-specific, multi-statistical parameter 3D QA measurements with gantry-mounted COMPASS also showed good agreement. Conclusion: Constant dose rate VMAT was successfully modeled in Raystation 4.7 for a Varian Clinac iX, and Raystation’s multicriteria optimization generated constant dose rate VMAT plans which were deliverable and dosimetrically comparable to IMRT plans.« less

  17. 40 CFR 90.408 - Pre-test procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... systems. While this would typically be done before testing, it may also be done as a post-test... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Pre-test procedures. 90.408 Section 90...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust Test...

  18. 40 CFR 90.408 - Pre-test procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... systems. While this would typically be done before testing, it may also be done as a post-test... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Pre-test procedures. 90.408 Section 90...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust Test...

  19. 40 CFR 90.408 - Pre-test procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... systems. While this would typically be done before testing, it may also be done as a post-test... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Pre-test procedures. 90.408 Section 90...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust Test...

  20. 40 CFR 90.408 - Pre-test procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... systems. While this would typically be done before testing, it may also be done as a post-test... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Pre-test procedures. 90.408 Section 90...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust Test...

  1. 40 CFR 90.408 - Pre-test procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... systems. While this would typically be done before testing, it may also be done as a post-test... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Pre-test procedures. 90.408 Section 90...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Gaseous Exhaust Test...

  2. Hanford isotope project strategic business analysis yttrium-90 (Y-90)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-10-01

    The purpose of this analysis is to address the short-term direction for the Hanford yttrium-90 (Y-90) project. Hanford is the sole DOE producer of Y-90, and is the largest repository for its source in this country. The production of Y-90 is part of the DOE Isotope Production and Distribution (IP and D) mission. The Y-90 is ``milked`` from strontium-90 (Sr-90), a byproduct of the previous Hanford missions. The use of Sr-90 to produce Y-90 could help reduce the amount of waste material processed and the related costs incurred by the clean-up mission, while providing medical and economic benefits. The costmore » of producing Y-90 is being subsidized by DOE-IP and D due to its use for research, and resultant low production level. It is possible that the sales of Y-90 could produce full cost recovery within two to three years, at two curies per week. Preliminary projections place the demand at between 20,000 and 50,000 curies per year within the next ten years, assuming FDA approval of one or more of the current therapies now in clinical trials. This level of production would incentivize private firms to commercialize the operation, and allow the government to recover some of its sunk costs. There are a number of potential barriers to the success of the Y-90 project, outside the control of the Hanford Site. The key issues include: efficacy, Food and Drug Administration (FDA) approval and medical community acceptance. There are at least three other sources for Y-90 available to the US users, but they appear to have limited resources to produce the isotope. Several companies have communicated interest in entering into agreements with Hanford for the processing and distribution of Y-90, including some of the major pharmaceutical firms in this country.« less

  3. 41 CFR 300-90.2 - Who may authorize test programs?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 41 Public Contracts and Property Management 4 2014-07-01 2014-07-01 false Who may authorize test programs? 300-90.2 Section 300-90.2 Public Contracts and Property Management Federal Travel Regulation System GENERAL AGENCY REQUIREMENTS 90-TELEWORK TRAVEL EXPENSES TEST PROGRAMS § 300-90.2 Who may authorize...

  4. Simulating Supercapacitors: Can We Model Electrodes As Constant Charge Surfaces?

    PubMed

    Merlet, Céline; Péan, Clarisse; Rotenberg, Benjamin; Madden, Paul A; Simon, Patrice; Salanne, Mathieu

    2013-01-17

    Supercapacitors based on an ionic liquid electrolyte and graphite or nanoporous carbon electrodes are simulated using molecular dynamics. We compare a simplified electrode model in which a constant, uniform charge is assigned to each carbon atom with a realistic model in which a constant potential is applied between the electrodes (the carbon charges are allowed to fluctuate). We show that the simulations performed with the simplified model do not provide a correct description of the properties of the system. First, the structure of the adsorbed electrolyte is partly modified. Second, dramatic differences are observed for the dynamics of the system during transient regimes. In particular, upon application of a constant applied potential difference, the increase in the temperature, due to the Joule effect, associated with the creation of an electric current across the cell follows Ohm's law, while unphysically high temperatures are rapidly observed when constant charges are assigned to each carbon atom.

  5. Dielectric relaxation studies in Se{sub 90}Cd{sub 8}Sb{sub 2} glassy alloy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shukla, Nitesh; Rao, Vandita; Dwivedi, D. K.

    2016-05-06

    Se{sub 90}Cd{sub 8}Sb{sub 2} chalcogenide semiconducting alloy was prepared by melt quench technique. The prepared glassy alloy has been characterized by techniques such as scanning electron microscopy (SEM) and energy dispersive X-ray (EDAX).Dielectric properties of Se{sub 90}Cd{sub 8}Sb{sub 2} chalcogenide semiconductor have been studied using impedance spectroscopic technique in the frequency range 5×10{sup 2}Hz - 1×10{sup 5}Hz and in temperature range 303-318K. It is found that dielectric constant ε′ and dielectric loss factor ε″ are dependent on frequency and temperature.

  6. Visual reaction time for chromaticity changes at constant luminance in different color representation systems

    NASA Astrophysics Data System (ADS)

    Jimenezdel Barco, L.; Jimenez, J. R.; Rubino, M.; Diaz, J. A.

    1996-09-01

    The results obtained by different authors show that when a color stimulus changes in both luminance and chromaticity, the visual reaction time (VRT) of an observer in detecting this chromatic change depends on nothing more than the luminance change and is regulated by Pieron's law. In the present work, we evaluate the VRT needed by an observer to detect the chromaticity difference between an adapting and variable stimulus. For this, we have used the experimental method of hue substitution, which allows us to maintain the luminance channel constant and thereby study the temporal response to changes only in chromaticity. The experiments were carried out with a CRT color monitor and the experimental results are expressed in different color-representation systems. The systems UCS-CIE 1964 (U*, V*, W*) and CIELUV show good correlations between the VRT and the chromaticity difference expressed in these systems, adjusting the VRT to an expression following Pieron's law: VRT-VRTon=k( Delta E)- beta .

  7. Status and methodology of publicly available national HIV care continua and 90-90-90 targets: A systematic review.

    PubMed

    Granich, Reuben; Gupta, Somya; Hall, Irene; Aberle-Grasse, John; Hader, Shannon; Mermin, Jonathan

    2017-04-01

    In 2014, the Joint United Nations Program on HIV/AIDS (UNAIDS) issued treatment goals for human immunodeficiency virus (HIV). The 90-90-90 target specifies that by 2020, 90% of individuals living with HIV will know their HIV status, 90% of people with diagnosed HIV infection will receive antiretroviral treatment (ART), and 90% of those taking ART will be virally suppressed. Consistent methods and routine reporting in the public domain will be necessary for tracking progress towards the 90-90-90 target. For the period 2010-2016, we searched PubMed, UNAIDS country progress reports, World Health Organization (WHO), UNAIDS reports, national surveillance and program reports, United States President's Emergency Plan for AIDS Relief (PEPFAR) Country Operational Plans, and conference presentations and/or abstracts for the latest available national HIV care continuum in the public domain. Continua of care included the number and proportion of people living with HIV (PLHIV) who are diagnosed, on ART, and virally suppressed out of the estimated number of PLHIV. We ranked the described methods for indicators to derive high-, medium-, and low-quality continuum. For 2010-2016, we identified 53 national care continua with viral suppression estimates representing 19.7 million (54%) of the 2015 global estimate of PLHIV. Of the 53, 6 (with 2% of global burden) were high quality, using standard surveillance methods to derive an overall denominator and program data from national cohorts for estimating steps in the continuum. Only nine countries in sub-Saharan Africa had care continua with viral suppression estimates. Of the 53 countries, the average proportion of the aggregate of PLHIV from all countries on ART was 48%, and the proportion of PLHIV who were virally suppressed was 40%. Seven countries (Sweden, Cambodia, United Kingdom, Switzerland, Denmark, Rwanda, and Namibia) were within 12% and 10% of achieving the 90-90-90 target for "on ART" and for "viral suppression

  8. KSC-pa90-03

    NASA Image and Video Library

    1998-05-03

    KENNEDY SPACE CENTER, FLA. -- The orbiter Columbia is about to touch down on Runway 33 of KSC's Shuttle Landing Facility to complete the nearly 16-day STS-90 mission. Main gear touchdown was at 12:08:59 p.m. EDT on May 3, 1998, landing on orbit 256 of the mission. The wheels stopped at 12:09:58 EDT, completing a total mission time of 15 days, 21 hours, 50 minutes and 58 seconds. The 90th Shuttle mission was Columbia's 13th landing at the space center and the 43rd KSC landing in the history of the Space Shuttle program. During the mission, the crew conducted research to contribute to a better understanding of the human nervous system. The crew of the STS-90 Neurolab mission include Commander Richard Searfoss; Pilot Scott Altman; Mission Specialists Richard Linnehan, D.V.M., Dafydd (Dave) Williams, M.D., with the Canadian Space Agency, and Kathryn (Kay) Hire; and Payload Specialists Jay Buckey, M.D., and James Pawelczyk, Ph.D

  9. KSC-pa90-05

    NASA Image and Video Library

    1998-05-03

    KENNEDY SPACE CENTER, FLA. -- The orbiter Columbia is about to touch down on Runway 33 of KSC's Shuttle Landing Facility to complete the nearly 16-day STS-90 mission. Main gear touchdown was at 12:08:59 p.m. EDT on May 3, 1998, landing on orbit 256 of the mission. The wheels stopped at 12:09:58 EDT, completing a total mission time of 15 days, 21 hours, 50 minutes and 58 seconds. The 90th Shuttle mission was Columbia's 13th landing at the space center and the 43rd KSC landing in the history of the Space Shuttle program. During the mission, the crew conducted research to contribute to a better understanding of the human nervous system. The crew of the STS-90 Neurolab mission include Commander Richard Searfoss; Pilot Scott Altman; Mission Specialists Richard Linnehan, D.V.M., Dafydd (Dave) Williams, M.D., with the Canadian Space Agency, and Kathryn (Kay) Hire; and Payload Specialists Jay Buckey, M.D., and James Pawelczyk, Ph.D

  10. Assessment of langatate material constants and temperature coefficients using SAW delay line measurements.

    PubMed

    Sturtevant, Blake T; Pereira da Cunha, Mauricio

    2010-03-01

    This paper reports on the assessment of langatate (LGT) acoustic material constants and temperature coefficients by surface acoustic wave (SAW) delay line measurements up to 130 degrees C. Based upon a full set of material constants recently reported by the authors, 7 orientations in the LGT plane with Euler angles (90 degrees, 23 degrees, Psi) were identified for testing. Each of the 7 selected orientations exhibited calculated coupling coefficients (K(2)) between 0.2% and 0.75% and also showed a large range of predicted temperature coefficient of delay (TCD) values around room temperature. Additionally, methods for estimating the uncertainty in predicted SAW propagation properties were developed and applied to SAW phase velocity and temperature coefficient of delay calculations. Starting from a purchased LGT boule, the SAW wafers used in this work were aligned, cut, ground, and polished at University of Maine facilities, followed by device fabrication and testing. Using repeated measurements of 2 devices on separate wafers for each of the 7 orientations, the room temperature SAW phase velocities were extracted with a precision of 0.1% and found to be in agreement with the predicted values. The normalized frequency change and the temperature coefficient of delay for all 7 orientations agreed with predictions within the uncertainty of the measurement and the predictions over the entire 120 degrees C temperature range measured. Two orientations, with Euler angles (90 degrees, 23 degrees, 123 degrees) and (90 degrees, 23 degrees, 119 degrees), were found to have high predicted coupling for LGT (K(2) > 0.5%) and were shown experimentally to exhibit temperature compensation in the vicinity of room temperature, with turnover temperatures at 50 and 60 degrees C, respectively.

  11. 47 CFR 90.373 - Eligibility in the DSRCS.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Eligibility in the DSRCS. 90.373 Section 90.373 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Intelligent Transportation Systems Radio Service Regulations Governing the...

  12. Computation of Nonretarded London Dispersion Coefficients and Hamaker Constants of Copper Phthalocyanine.

    PubMed

    Zhao, Yan; Ng, Hou T; Hanson, Eric; Dong, Jiannan; Corti, David S; Franses, Elias I

    2010-02-09

    A time-dependent density functional theory (TDDFT) scheme has been validated for predictions of the dispersion coefficients of five molecules (H2O, NH3, CO2, C6H6, and pentane) and for predictions of the static dipole polarizabilities of three organometallic compounds (TiCl4, OsO4, and Ge(CH3)4). The convergence of grid spacing has been examined, and two types of pseudopotentials and 13 density functionals have been tested. The nonretarded Hamaker constants A11 are calculated by employing a semiempirical parameter a along with the standard Hamaker constant equation. The parameter a is optimized against six accurate Hamaker constants obtained from the full Lifshitz theory. The dispersion coefficients of copper phthalocyanine CuPc and CuPc-SO3H are then computed. Using the theoretical densities of ρ1 = 1.63 and 1.62 g/cm(3), the Hamaker constants A11 of crystalline α-CuPc and β-CuPc are found to be 14.73 × 10(-20) and 14.66 × 10(-20) J, respectively. Using the experimentally derived density of ρ1 = 1.56 g/cm(3) for a commercially available β-CuPc (nanoparticles of ∼90 nm hydrodynamic diameter), A11 = 13.52 × 10(-20) J is found. Its corresponding effective Hamaker constant in water (A121) is calculated to be 3.07 × 10(-20) J. All computed A11 values for CuPc are noted to be higher than those reported previously.

  13. Elastic Constants of Ni-Mn-Ga Magnetic Shape Memory Alloys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stipcich, M.; Manosa, L.; Planes, A.

    2004-01-01

    We have measured the adiabatic second order elastic constants of two Ni-Mn-Ga magnetic shape memory crystals with different martensitic transition temperatures, using ultrasonic methods. The temperature dependence of the elastic constants has been followed across the ferromagnetic transition and down to the martensitic transition temperature. Within experimental errors no noticeable change in any of the elastic constants has been observed at the Curie point. The temperature dependence of the shear elastic constant C' has been found to be very different for the two alloys. Such a different behavior is in agreement with recent theoretical predictions for systems undergoing multi-stage structuralmore » transitions.« less

  14. SU-F-J-182: Investigation of Systems for Improved Accuracy in Clinical Y-90 Percent Delivered Calculations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McBeth, R; Elder, D; Kesner, A

    2016-06-15

    Purpose: Y-90 Selective Internal Radiation Therapy (SIRT) is used to treat liver tumors, and by nature has variability in the percent of the intended dose that is actually delivered. To determine the quality of the administration, pre and post activity measurements are taken, and used to infer percent delivered. Vendor specifications indicate the use of an ion chamber to take these measurements. In our work, we investigated the accuracy of ion chambers, and compared them to other detector systems. Methods: We have built phantoms, phantom holders, and protocols, which allow us to measure our Y90 doses with varying apparatuses: amore » dose calibrator, a Geiger-counter, an ion chamber, a crystal based thyroid probe, and a gamma camera. We have set up a system that has enabled us to gather data by measuring clinical Y90 doses as they are used in the clinic using all of the instrumental methods. Five initial doses (25 measurements/acquisitions) have been taken at the time of this abstract submission. Results: Our initial results show that measurements acquired using scintillation based detectors (thyroid probe and gamma camera) correlate better with the gold standard (i.e. the dose calibrator). Pearson correlations between the dose calibrator measurements and the GM counter, Ion chamber, thyroid probe, and gamma camera were found to be 0.88, 0.83, 0.98, 0.99, respectively. More acquisitions and analysis are planned to determine the precision of the systems, as well as optimal energy window settings. Conclusion: It is likely that current standard practice can be improved using scintillation crystal based detectors. Such systems are more sensitive, can integrate signal, and can use energy discrimination. Furthermore, phantoms can be built to integrate with probe and gamma camera systems that are robust and provide reproducibility. Future work will include expanded acquisition and analysis.« less

  15. Design verification of large time constant thermal shields for optical reference cavities.

    PubMed

    Zhang, J; Wu, W; Shi, X H; Zeng, X Y; Deng, K; Lu, Z H

    2016-02-01

    In order to achieve high frequency stability in ultra-stable lasers, the Fabry-Pérot reference cavities shall be put inside vacuum chambers with large thermal time constants to reduce the sensitivity to external temperature fluctuations. Currently, the determination of thermal time constants of vacuum chambers is based either on theoretical calculation or time-consuming experiments. The first method can only apply to simple system, while the second method will take a lot of time to try out different designs. To overcome these limitations, we present thermal time constant simulation using finite element analysis (FEA) based on complete vacuum chamber models and verify the results with measured time constants. We measure the thermal time constants using ultrastable laser systems and a frequency comb. The thermal expansion coefficients of optical reference cavities are precisely measured to reduce the measurement error of time constants. The simulation results and the experimental results agree very well. With this knowledge, we simulate several simplified design models using FEA to obtain larger vacuum thermal time constants at room temperature, taking into account vacuum pressure, shielding layers, and support structure. We adopt the Taguchi method for shielding layer optimization and demonstrate that layer material and layer number dominate the contributions to the thermal time constant, compared with layer thickness and layer spacing.

  16. The Hsp90 chaperone complex regulates GDI-dependent Rab recycling.

    PubMed

    Chen, Christine Y; Balch, William E

    2006-08-01

    Rab GTPase regulated hubs provide a framework for an integrated coding system, the membrome network, that controls the dynamics of the specialized exocytic and endocytic membrane architectures found in eukaryotic cells. Herein, we report that Rab recycling in the early exocytic pathways involves the heat-shock protein (Hsp)90 chaperone system. We find that Hsp90 forms a complex with guanine nucleotide dissociation inhibitor (GDI) to direct recycling of the client substrate Rab1 required for endoplasmic reticulum (ER)-to-Golgi transport. ER-to-Golgi traffic is inhibited by the Hsp90-specific inhibitors geldanamycin (GA), 17-(dimethylaminoethylamino)-17-demethoxygeldanamycin (17-DMAG), and radicicol. Hsp90 activity is required to form a functional GDI complex to retrieve Rab1 from the membrane. Moreover, we find that Hsp90 is essential for Rab1-dependent Golgi assembly. The observation that the highly divergent Rab GTPases Rab1 involved in ER-to-Golgi transport and Rab3A involved in synaptic vesicle fusion require Hsp90 for retrieval from membranes lead us to now propose that the Hsp90 chaperone system may function as a general regulator for Rab GTPase recycling in exocytic and endocytic trafficking pathways involved in cell signaling and proliferation.

  17. 76 FR 41395 - Airworthiness Directives; General Electric Company GE90-76B; GE90-77B; GE90-85B; GE90-90B; and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-14

    ... repetitive fluorescent penetrant inspections (FPIs) and eddy current inspections (ECIs) of the high-pressure... engine operation, since the high-pressure module overhaul interval is 48,000 hours or 6,000 cycles when...-90B; and GE90-94B turbofan engines with a high- pressure compressor rotor (HPCR) 8-10 stage spool...

  18. The Energy Implications of Air-Side Fouling in Constant Air Volume HVAC Systems

    NASA Astrophysics Data System (ADS)

    Wilson, Eric J. H.

    2011-12-01

    This thesis examines the effect of air-side fouling on the energy consumption of constant air volume (CAV) heating, ventilating, and air conditioning (HVAC) systems in residential and small commercial buildings. There is a particular focus on evaluating the potential energy savings that may result from the remediation of such fouling from coils, filters, and other air system components. A computer model was constructed to simulate the behavior of a building and its duct system under various levels of fouling. The model was verified through laboratory and field testing and then used to run parametric simulations to examine the range of energy impacts for various climates and duct system characteristics. A sensitivity analysis was conducted to determine the impact of parameters like duct insulation, duct leakage, duct location, and duct design on savings potential. Duct system pressures, temperatures, and energy consumption for two houses were monitored for one month. The houses' duct systems, which were both in conditioned space, were given a full cleaning, and were then monitored for another month. The flow rates at the houses improved by 10% and 6%. The improvements were primarily due to installing a new filter, as both houses had only light coil fouling. The results indicate that there was negligible change in heating energy efficiency due to the system cleaning. The parametric simulation results are in agreement with the field experiment: for systems in all eight climates, with flowrates degraded by 20% or less, if ducts are located within the thermal zone, HVAC source energy savings from cleaning are negligible or even slightly negative. However, if ducts are outside the thermal zone, savings are in the 1 to 5% range. For systems with flowrates degraded by 40%, if ducts are within the thermal zone, savings from cleaning occurs only for air conditioning energy, up to 8% in climates like Miami, FL. If ducts are outside the thermal zone, savings occurs with both

  19. America's Freight System in the 80's and 90's ... But How to Get There? : Conference Papers on Advance Freight System Technology

    DOT National Transportation Integrated Search

    1976-12-01

    These papers relating to technology and freight transportation have been prepared for the conference on America's Freight System in the 80's and 90's. It does not purport to be a compendium on all advanced freight technology but is to give an overvie...

  20. Constant load and constant volume response of municipal solid waste in simple shear.

    PubMed

    Zekkos, Dimitrios; Fei, Xunchang

    2017-05-01

    Constant load and constant volume simple shear testing was conducted on relatively fresh municipal solid waste (MSW) from two landfills in the United States, one in Michigan and a second in Texas, at respective natural moisture content below field capacity. The results were assessed in terms of two failure strain criteria, at 10% and 30% shear strain, and two interpretations of effective friction angle. Overall, friction angle obtained assuming that the failure plane is horizontal and at 10% shear strain resulted in a conservative estimation of shear strength of MSW. Comparisons between constant volume and constant load simple shear testing results indicated significant differences in the shear response of MSW with the shear resistance in constant volume being lower than the shear resistance in constant load. The majority of specimens were nearly uncompacted during specimen preparation to reproduce the state of MSW in bioreactor landfills or in uncontrolled waste dumps. The specimens had identical percentage of <20mm material but the type of <20mm material was different. The <20mm fraction from Texas was finer and of high plasticity. MSW from Texas was overall weaker in both constant load and constant volume conditions compared to Michigan waste. The results of these tests suggest the possibility of significantly lower shear strength of MSW in bioreactor landfills where waste is placed with low compaction effort and constant volume, i.e., "undrained", conditions may occur. Compacted MSW specimens resulted in shear strength parameters that are higher than uncompacted specimens and closer to values reported in the literature. However, the normalized undrained shear strength in simple shear for uncompacted and compacted MSW was still higher than the normalized undrained shear strength reported in the literature for clayey and silty soils. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Influences of brain tissue poroelastic constants on intracranial pressure (ICP) during constant-rate infusion.

    PubMed

    Li, Xiaogai; von Holst, Hans; Kleiven, Svein

    2013-01-01

    A 3D finite element (FE) model has been developed to study the mean intracranial pressure (ICP) response during constant-rate infusion using linear poroelasticity. Due to the uncertainties in the poroelastic constants for brain tissue, the influence of each of the main parameters on the transient ICP infusion curve was studied. As a prerequisite for transient analysis, steady-state simulations were performed first. The simulated steady-state pressure distribution in the brain tissue for a normal cerebrospinal fluid (CSF) circulation system showed good correlation with experiments from the literature. Furthermore, steady-state ICP closely followed the infusion experiments at different infusion rates. The verified steady-state models then served as a baseline for the subsequent transient models. For transient analysis, the simulated ICP shows a similar tendency to that found in the experiments, however, different values of the poroelastic constants have a significant effect on the infusion curve. The influence of the main poroelastic parameters including the Biot coefficient α, Skempton coefficient B, drained Young's modulus E, Poisson's ratio ν, permeability κ, CSF absorption conductance C(b) and external venous pressure p(b) was studied to investigate the influence on the pressure response. It was found that the value of the specific storage term S(ε) is the dominant factor that influences the infusion curve, and the drained Young's modulus E was identified as the dominant parameter second to S(ε). Based on the simulated infusion curves from the FE model, artificial neural network (ANN) was used to find an optimised parameter set that best fit the experimental curve. The infusion curves from both the FE simulation and using ANN confirmed the limitation of linear poroelasticity in modelling the transient constant-rate infusion.

  2. Shock tube measurements of growth constants in the branched-chain ethane-carbon monoxide-oxygen system

    NASA Technical Reports Server (NTRS)

    Brokaw, R. S.; Brabbs, T. A.; Snyder, C. A.

    1985-01-01

    Exponential free radical growth constants have been measured for ethane carbon monoxide oxygen mixtures by monitoring the growth of oxygen atom concentration as manifested by CO flame band emission. Data were obtained over the temperature range of 1200 to 1700 K. The data were analyzed using an ethane oxidation mechanism involving seven elementary reaction steps. Calculated growth constants were close to experimental values at lower temperatures, up to about 1400 K, but at higher temperatures computed growth constants were considerably smaller than experiment. In attempts to explain these results additional branching reactions were added to the mechanism. However, these additional reactions did not appreciably change calculated growth constants.

  3. The Dynamics of Tightly-packed Planetary Systems in the Presence of an Outer Planet: Case Studies Using Kepler-11 and Kepler-90

    NASA Astrophysics Data System (ADS)

    Granados Contreras, A. P.; Boley, A. C.

    2018-03-01

    We explore the effects of an undetected outer giant planet on the dynamics, observability, and stability of Systems with Tightly-packed Inner Planets (STIPs). We use direct numerical simulations along with secular theory and synthetic secular frequency spectra to analyze how analogues of Kepler-11 and Kepler-90 behave in the presence of a nearly co-planar, Jupiter-like outer perturber with semimajor axes between 1 and 5.2 au. Most locations of the outer perturber do not affect the evolution of the inner planetary systems, apart from altering precession frequencies. However, there are locations at which an outer planet causes system instability due to, in part, secular eccentricity resonances. In Kepler-90, there is a range of orbital distances for which the outer perturber drives planets b and c, through secular interactions, onto orbits with inclinations that are ∼16° away from the rest of the planets. Kepler-90 is stable in this configuration. Such secular resonances can thus affect the observed multiplicity of transiting systems. We also compare the synthetic apsidal and nodal precession frequencies with the secular theory and find some misalignment between principal frequencies, indicative of strong interactions between the planets (consistent with the system showing TTVs). First-order libration angles are calculated to identify MMRs in the systems, for which two near-MMRs are shown in Kepler-90, with a 5:4 between b and c, as well as a 3:2 between g and h.

  4. Determination of the distribution constants of aromatic compounds and steroids in biphasic micellar phosphonium ionic liquid/aqueous buffer systems by capillary electrokinetic chromatography.

    PubMed

    Lokajová, Jana; Railila, Annika; King, Alistair W T; Wiedmer, Susanne K

    2013-09-20

    The distribution constants of some analytes, closely connected to the petrochemical industry, between an aqueous phase and a phosphonium ionic liquid phase, were determined by ionic liquid micellar electrokinetic chromatography (MEKC). The phosphonium ionic liquids studied were the water-soluble tributyl(tetradecyl)phosphonium with chloride or acetate as the counter ion. The retention factors were calculated and used for determination of the distribution constants. For calculating the retention factors the electrophoretic mobilities of the ionic liquids were required, thus, we adopted the iterative process, based on a homologous series of alkyl benzoates. Calculation of the distribution constants required information on the phase-ratio of the systems. For this the critical micelle concentrations (CMC) of the ionic liquids were needed. The CMCs were calculated using a method based on PeakMaster simulations, using the electrophoretic mobilities of system peaks. The resulting distribution constants for the neutral analytes between the ionic liquid and the aqueous (buffer) phase were compared with octanol-water partitioning coefficients. The results indicate that there are other factors affecting the distribution of analytes between phases, than just simple hydrophobic interactions. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Effects of system net charge and electrostatic truncation on all-atom constant pH molecular dynamics †

    PubMed Central

    Chen, Wei; Shen, Jana K.

    2014-01-01

    Constant pH molecular dynamics offers a means to rigorously study the effects of solution pH on dynamical processes. Here we address two critical questions arising from the most recent developments of the all-atom continuous constant pH molecular dynamics (CpHMD) method: 1) What is the effect of spatial electrostatic truncation on the sampling of protonation states? 2) Is the enforcement of electrical neutrality necessary for constant pH simulations? We first examined how the generalized reaction field and force shifting schemes modify the electrostatic forces on the titration coordinates. Free energy simulations of model compounds were then carried out to delineate the errors in the deprotonation free energy and salt-bridge stability due to electrostatic truncation and system net charge. Finally, CpHMD titration of a mini-protein HP36 was used to understand the manifestation of the two types of errors in the calculated pK a values. The major finding is that enforcing charge neutrality under all pH conditions and at all time via co-titrating ions significantly improves the accuracy of protonation-state sampling. We suggest that such finding is also relevant for simulations with particle-mesh Ewald, considering the known artifacts due to charge-compensating background plasma. PMID:25142416

  6. 90-94 ITS Intercity Corridor Study - Strategic Deployment Plan

    DOT National Transportation Integrated Search

    1996-12-01

    PUBLIC-PRIVATE PARTNERSHIP, COMMERCIAL VEHICLES OPERATIONS OR CVO : THE IH 90/94 ITS INTERCITY CORRIDOR STRATEGIC DEPLOYMENT PLAN IS AN APPROACH FOR IMPLEMENTING INTELLIGENT TRANSPORTATION SYSTEMS (ITS) IN THE IH 90/94 CORRIDORS THAT TRAVERSE THE ...

  7. Electronic transport in two-dimensional high dielectric constant nanosystems

    DOE PAGES

    Ortuño, M.; Somoza, A. M.; Vinokur, V. M.; ...

    2015-04-10

    There has been remarkable recent progress in engineering high-dielectric constant two dimensional (2D) materials, which are being actively pursued for applications in nanoelectronics in capacitor and memory devices, energy storage, and high-frequency modulation in communication devices. Yet many of the unique properties of these systems are poorly understood and remain unexplored. Here we report a numerical study of hopping conductivity of the lateral network of capacitors, which models two-dimensional insulators, and demonstrate that 2D long-range Coulomb interactions lead to peculiar size effects. We find that the characteristic energy governing electronic transport scales logarithmically with either system size or electrostatic screeningmore » length depending on which one is shorter. Our results are relevant well beyond their immediate context, explaining, for example, recent experimental observations of logarithmic size dependence of electric conductivity of thin superconducting films in the critical vicinity of superconductor-insulator transition where a giant dielectric constant develops. Our findings mark a radical departure from the orthodox view of conductivity in 2D systems as a local characteristic of materials and establish its macroscopic global character as a generic property of high-dielectric constant 2D nanomaterials.« less

  8. Electronic transport in two-dimensional high dielectric constant nanosystems.

    PubMed

    Ortuño, M; Somoza, A M; Vinokur, V M; Baturina, T I

    2015-04-10

    There has been remarkable recent progress in engineering high-dielectric constant two dimensional (2D) materials, which are being actively pursued for applications in nanoelectronics in capacitor and memory devices, energy storage, and high-frequency modulation in communication devices. Yet many of the unique properties of these systems are poorly understood and remain unexplored. Here we report a numerical study of hopping conductivity of the lateral network of capacitors, which models two-dimensional insulators, and demonstrate that 2D long-range Coulomb interactions lead to peculiar size effects. We find that the characteristic energy governing electronic transport scales logarithmically with either system size or electrostatic screening length depending on which one is shorter. Our results are relevant well beyond their immediate context, explaining, for example, recent experimental observations of logarithmic size dependence of electric conductivity of thin superconducting films in the critical vicinity of superconductor-insulator transition where a giant dielectric constant develops. Our findings mark a radical departure from the orthodox view of conductivity in 2D systems as a local characteristic of materials and establish its macroscopic global character as a generic property of high-dielectric constant 2D nanomaterials.

  9. Study the Output Characteristics of a 90 kJ Filippove-Type Plasma Focus

    NASA Astrophysics Data System (ADS)

    Sadat Kiai, S. M.; Talaei, A.; Adlparvar, S.; Zirak, A.; Elahi, M.; Safarian, A.; Farhangi, S.; Alhooie, S.; Dabirzadeh, A. A.; Khalaj, M. M.; Mahlooji, M. S.; Talaei, M.; KaKaei, S.; Sheibani, S.; Kashani, A.; Zahedi, F.

    2010-08-01

    The output characteristics of a Filippove-Type plasma focus "Dena" (288 μF, 25 kV, 90 kJ) is numerically investigated by considering the voltage, current, current derivative, and maximum current as a function of capacitor bank energy in the constant Argon gas pressure and compared to the experiment. It is shown that increase on the bank energy leads to the increment on the maximum current and decrement on the pinch time.

  10. 47 CFR 90.1321 - Power and antenna limits.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Power and antenna limits. 90.1321 Section 90... and antenna limits. (a) Base and fixed stations are limited to 25 watts/25 MHz equivalent... receiver. (2) If the transmitter employs an antenna system that emits multiple directional beams but does...

  11. 47 CFR 90.1321 - Power and antenna limits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Power and antenna limits. 90.1321 Section 90... and antenna limits. (a) Base and fixed stations are limited to 25 watts/25 MHz equivalent... receiver. (2) If the transmitter employs an antenna system that emits multiple directional beams but does...

  12. 47 CFR 90.1321 - Power and antenna limits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Power and antenna limits. 90.1321 Section 90... and antenna limits. (a) Base and fixed stations are limited to 25 watts/25 MHz equivalent... receiver. (2) If the transmitter employs an antenna system that emits multiple directional beams but does...

  13. 47 CFR 90.1321 - Power and antenna limits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Power and antenna limits. 90.1321 Section 90... and antenna limits. (a) Base and fixed stations are limited to 25 watts/25 MHz equivalent... receiver. (2) If the transmitter employs an antenna system that emits multiple directional beams but does...

  14. 47 CFR 90.1321 - Power and antenna limits.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Power and antenna limits. 90.1321 Section 90... and antenna limits. (a) Base and fixed stations are limited to 25 watts/25 MHz equivalent... receiver. (2) If the transmitter employs an antenna system that emits multiple directional beams but does...

  15. Solubility-product constant and thermodynamic properties for synthetic otavite, CdCO3(s), and aqueous association constants for the Cd(II)-CO2-H2O system

    USGS Publications Warehouse

    Stipp, S.L.S.; Parks, George A.; Nordstrom, D. Kirk; Leckie, J.O.

    1993-01-01

    Considerable disparity exists in the published thermodynamic data for selected species in the Cd(II)-CO2-H2O system near 25??C and 1 atm pressure. Evaluation of published experimental and estimated data for aqueous cadmium-carbonate species suggests an association constant, pK, of -3.0 ?? 0.4 for CdCO30, about -1.5 for CdHCO3+, and -6.4 ?? 0.1 for Cd(CO3)22- (T = 298.15 K; P = 1 atm; I = 0). Examination of all available data for cadmium-hydrolysis species and ??-Cd(OH)2(s)) confirms that the consistent set of constants presented by Baes and Mesmer (Hydrolysis of Cations, 1976) is the best available. The solubility of synthetic otavite, CdCO3(s), has been measured in KClO4 solutions where I ??? 0.1 M. We calculated pKsp = 12.1 ?? 0.1 (T = 25.0??C; P = 1 atm; I = 0) from measured concentrations of Cd2+, measured PC02 and pH, our selected set of equilibrium constants, and activity corrections estimated using the Davies equation. Values at 5 and 50??C were 12.4 ?? 0.1 and 12.2 ?? 0.1, respectively. Based on the new solubility data and the CODATA key values for Cd2+ and CO32-, a new set of thermodynamic properties is recommended for otavite: ??Gf0 = -674.7 ?? 0.6 kJ/mol; ??Hf0 = -751.9 ?? 10 kJ/mol; S0 = 106 ?? 30 J/mol K; and ??Gr0 for the reaction Cd2+ + CO32- ??? CdCO3(s) is -69.08 ?? 0.57 kJ/m. ?? 1993.

  16. Nonlocal conservation laws of the constant astigmatism equation

    NASA Astrophysics Data System (ADS)

    Hlaváč, Adam; Marvan, Michal

    2017-03-01

    For the constant astigmatism equation, we construct a system of nonlocal conservation laws (an abelian covering) closed under the reciprocal transformations. The corresponding potentials are functionally independent modulo a Wronskian type relation.

  17. Automated system for measuring temperature profiles inside ITS-90 fixed-point cells

    NASA Astrophysics Data System (ADS)

    Hiti, Miha; Bojkovski, Jovan; Batagelj, Valentin; Drnovsek, Janko

    2005-11-01

    The defining fixed points of the International Temperature Scale of 1990 (ITS-90) are temperature reference points for temperature calibration. The measured temperature inside the fixed-point cell depends on thermometer immersion, since measurements are made below the surface of the fixed-point material and the additional effect of the hydrostatic pressure has to be taken into account. Also, the heat flux along the thermometer stem can affect the measured temperature. The paper presents a system that enables accurate and reproducible immersion profile measurements for evaluation of measurement sensitivity and adequacy of thermometer immersion. It makes immersion profile measurements possible, where a great number of repetitions and long measurement periods are required, and reduces the workload on the user for performing such measurements. The system is flexible and portable and was developed for application to existing equipment in the laboratory. Results of immersion profile measurements in a triple point of water fixed-point cell are presented.

  18. 48 CFR 3052.223-90 - Accident and fire reporting (USCG).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Accident and fire reporting (USCG). 3052.223-90 Section 3052.223-90 Federal Acquisition Regulations System DEPARTMENT OF... $1,000 or more to Federal real or personal property; either real or personal; (3) Damage of $1,000 or...

  19. Cosmological constant and quantum gravitational corrections to the running fine structure constant.

    PubMed

    Toms, David J

    2008-09-26

    The quantum gravitational contribution to the renormalization group behavior of the electric charge in Einstein-Maxwell theory with a cosmological constant is considered. Quantum gravity is shown to lead to a contribution to the running charge not present when the cosmological constant vanishes. This reopens the possibility, suggested by Robinson and Wilczek, of altering the scaling behavior of gauge theories at high energies although our result differs. We show the possibility of an ultraviolet fixed point that is linked directly to the cosmological constant.

  20. Higher success rate with transcranial electrical stimulation of motor-evoked potentials using constant-voltage stimulation compared with constant-current stimulation in patients undergoing spinal surgery.

    PubMed

    Shigematsu, Hideki; Kawaguchi, Masahiko; Hayashi, Hironobu; Takatani, Tsunenori; Iwata, Eiichiro; Tanaka, Masato; Okuda, Akinori; Morimoto, Yasuhiko; Masuda, Keisuke; Tanaka, Yuu; Tanaka, Yasuhito

    2017-10-01

    During spine surgery, the spinal cord is electrophysiologically monitored via transcranial electrical stimulation of motor-evoked potentials (TES-MEPs) to prevent injury. Transcranial electrical stimulation of motor-evoked potential involves the use of either constant-current or constant-voltage stimulation; however, there are few comparative data available regarding their ability to adequately elicit compound motor action potentials. We hypothesized that the success rates of TES-MEP recordings would be similar between constant-current and constant-voltage stimulations in patients undergoing spine surgery. The objective of this study was to compare the success rates of TES-MEP recordings between constant-current and constant-voltage stimulation. This is a prospective, within-subject study. Data from 100 patients undergoing spinal surgery at the cervical, thoracic, or lumbar level were analyzed. The success rates of the TES-MEP recordings from each muscle were examined. Transcranial electrical stimulation with constant-current and constant-voltage stimulations at the C3 and C4 electrode positions (international "10-20" system) was applied to each patient. Compound muscle action potentials were bilaterally recorded from the abductor pollicis brevis (APB), deltoid (Del), abductor hallucis (AH), tibialis anterior (TA), gastrocnemius (GC), and quadriceps (Quad) muscles. The success rates of the TES-MEP recordings from the right Del, right APB, bilateral Quad, right TA, right GC, and bilateral AH muscles were significantly higher using constant-voltage stimulation than those using constant-current stimulation. The overall success rates with constant-voltage and constant-current stimulations were 86.3% and 68.8%, respectively (risk ratio 1.25 [95% confidence interval: 1.20-1.31]). The success rates of TES-MEP recordings were higher using constant-voltage stimulation compared with constant-current stimulation in patients undergoing spinal surgery. Copyright © 2017

  1. Comparisons of Hamaker constants for ceramic systems with intervening vacuum or water: From force laws and physical properties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ackler, H.D.; Chiang, Y.M.; French, R.H.

    1996-05-10

    Van der Waals dispersive forces produce attractive interactions between bodies, playing an important role in many material systems influencing colloidal and emulsion stability, wetting behavior, and intergranular forces in glass-ceramic systems. It is of technological importance to accurately quantify these interactions, conveniently represented by the Hamaker constant, A. To set the current level of accuracy for determining A, they were calculated from Lifshitz theory using full spectral data for muscovite mica, Al{sub 2}O{sub 3}, SiO{sub 2}, Si{sub 3}N{sub 4}, and rutile TiO{sub 2}, separated by vacuum or water. These were compared to Hamaker constants calculated from physical properties using themore » Tabor-Winterton approximation, a single oscillator model, a multiple oscillator model, and A`s calculated using force vs separation data from surface force apparatus and atomic force microscope studies. For materials with refractive indices between 1.4 and 1.8 separated by vacuum, all methods produce similar values, but for indices larger than 1.8 separated by vacuum, and any of these materials separated by water, results span a broader range. The present level of accuracy for the determination of Hamaker constants, here taken to be represented by the level of agreement between various methods, ranges from about 10% for the case of SiO{sub 2}/vacuum/SiO{sub 2} and TiO{sub 2}/water/TiO{sub 2} to a factor of approximately 7 for mica/water/mica.« less

  2. 40 CFR 90.306 - Dynamometer torque cell calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Dynamometer torque cell calibration. 90... Equipment Provisions § 90.306 Dynamometer torque cell calibration. (a)(1) Any lever arm used to convert a... (a)(6) of this section with the adjusted or repaired system. (b) Option. A master load-cell or...

  3. 47 CFR 90.663 - MTA-based SMR system operations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... and operate base stations using such frequency. [60 FR 21991, May 4, 1995] ... licensees authorized in the 896-901/935-940 MHz band pursuant to § 90.661 may construct and operate base stations using any frequency identified in their spectrum block anywhere within their authorized MTA...

  4. 47 CFR 90.683 - EA-based SMR system operations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... operate base stations using any of the base station frequencies identified in their spectrum block... use of frequencies identified in their spectrum block, including the provisions of § 90.619 relating... authorization for a previously authorized co-channel station within the EA licensee's spectrum block is...

  5. 47 CFR 90.683 - EA-based SMR system operations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... operate base stations using any of the base station frequencies identified in their spectrum block... use of frequencies identified in their spectrum block, including the provisions of § 90.619 relating... authorization for a previously authorized co-channel station within the EA licensee's spectrum block is...

  6. 47 CFR 90.683 - EA-based SMR system operations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... operate base stations using any of the base station frequencies identified in their spectrum block... use of frequencies identified in their spectrum block, including the provisions of § 90.619 relating... authorization for a previously authorized co-channel station within the EA licensee's spectrum block is...

  7. 46 CFR 56.90-10 - Threaded piping (modifies 135.5).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Threaded piping (modifies 135.5). 56.90-10 Section 56.90-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Assembly § 56.90-10 Threaded piping (modifies 135.5). (a) Any compound or...

  8. Apparatus producing constant cable tension for intermittent demand

    DOEpatents

    Lauritzen, Ted

    1985-01-01

    The disclosed apparatus produces constant tension in superconducting electrical cable, or some other strand, under conditions of intermittent demand, as the cable is unreeled from a reel or reeled thereon. The apparatus comprises a pivotally supported swing frame on which the reel is rotatably supported, a rotary motor, a drive train connected between the motor and the reel and including an electrically controllable variable torque slip clutch, a servo transducer connected to the swing frame for producing servo input signals corresponding to the position thereof, a servo control system connected between the transducer and the clutch for regulating the torque transmitted by the clutch to maintain the swing frame in a predetermined position, at least one air cylinder connected to the swing frame for counteracting the tension in the cable, and pressure regulating means for supplying a constant air pressure to the cylinder to establish the constant tension in the cable, the servo system and the clutch being effective to produce torque on the reel in an amount sufficient to provide tension in the cable corresponding to the constant force exerted by the air cylinder. The drive train also preferably includes a fail-safe brake operable to its released position by electrical power in common with the servo system, for preventing rotation of the reel if there is a power failure. A shock absorber and biasing springs may also be connected to the swing frame, such springs biasing the frame toward its predetermined position. The tension in the cable may be measured by force measuring devices engageable with the bearings for the reel shaft, such bearings being supported for slight lateral movement. The reel shaft is driven by a Shmidt coupler which accommodates such movement.

  9. Harmony in Career Learning and Scholastic System (Project HI-CLASS) 1989-90. OREA Final Evaluation Report.

    ERIC Educational Resources Information Center

    New York City Board of Education, Brooklyn, NY. Office of Research, Evaluation, and Assessment.

    An evaluation was done of New York City Board of Education's Project Harmony in Career Learning and Scholastic System (Project HI-CLASS) for 1989-90. In its second year of a funding cycle, the project offered 635 Chinese- and Spanish-speaking high school students of limited English proficiency instruction in English as a Second Language (ESL),…

  10. Investigation of the frequency response of constant voltage anemometers in turbulent flows

    NASA Astrophysics Data System (ADS)

    Sadeghi Hassanlouei, Atabak

    A commercially available anemometer system considered as a prototype, the constant voltage anemometer (CVA), is presented and its working principle is studied and analyzed. We detail the different procedures and corrections that have to be applied to voltage signals to deduce corresponding velocity signals, including the effect of the thermal inertia of the sensor. Results are compared to another anemometer system widely used in research and industry, the constant temperature anemometer (CTA), for validation requirements. Measurements are performed in the turbulent region of a subsonic axisymmetric jet and include mean velocities, root-mean-square (rms) values of velocity fluctuations and power spectral densities. In the same range of operation, we show that the two instruments give similar results. The CVA anemometer slightly underestimates the rms velocity values given by the CTA anemometer which is attributed to a non-linear effect. We show that the cut-off frequency of the CVA system is higher than the more commonly used CTA system, and that the electronic noise level is lower. The constant voltage anemometer is thus an excellent alternative to the constant temperature anemometer for low turbulent flows with rich frequency content, such as supersonic and hypersonic flows.

  11. Characterization of In-Flight Processing of Alumina Powder Using a DC-RF Hybrid Plasma Flow System at Constant Low Operating Power

    NASA Astrophysics Data System (ADS)

    Nishiyama, H.; Onodera, M.; Igawa, J.; Nakajima, T.

    2009-12-01

    The aim of this study is to provide the optimum operating conditions for enhancing in-flight alumina particle heating as much as possible for particle spheroidization and aggregation of melted particles using a DC-RF hybrid plasma flow system even at constant low operating power based on the thermofluid considerations. It is clarified that the swirl flow and higher operating pressure enhance the particle melting and aggregation of melted particles coupled with increasing gas temperature downstream of a plasma uniformly in the radial direction at constant electrical discharge conditions.

  12. 47 CFR 90.365 - Partitioned licenses and disaggregated spectrum.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Partitioned licenses and disaggregated spectrum. 90.365 Section 90.365 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Intelligent Transportation Systems Radio Service...

  13. Effect of Cold Temperature on the Dielectric Constant of Soil

    DTIC Science & Technology

    2012-04-01

    explosive device (IED) threats is ground-penetrating radar ( GPR ). Proper development of GPR technology for this application requires a unique...success or failure of GPR as a detection technique. One soil property of interest to radar engineers is the dielectric constant. Previous...results to temperatures, moisture levels, and frequencies relevant to GPR systems. 2. Dielectric Constant and the Ring-resonator Concept The two

  14. Appropriate control time constant in relation to characteristics of the baroreflex vascular system in 1/R control of the total artificial heart.

    PubMed

    Mizuta, Sora; Saito, Itsuro; Isoyama, Takashi; Hara, Shintaro; Yurimoto, Terumi; Li, Xinyang; Murakami, Haruka; Ono, Toshiya; Mabuchi, Kunihiko; Abe, Yusuke

    2017-09-01

    1/R control is a physiological control method of the total artificial heart (TAH) with which long-term survival was obtained with animal experiments. However, 1/R control occasionally diverged in the undulation pump TAH (UPTAH) animal experiment. To improve the control stability of the 1/R control, appropriate control time constant in relation to characteristics of the baroreflex vascular system was investigated with frequency analysis and numerical simulation. In the frequency analysis, data of five goats in which the UPTAH was implanted were analyzed with first Fourier transform technique to examine the vasomotion frequency. The numerical simulation was carried out repeatedly changing baroreflex parameters and control time constant using the elements-expanded Windkessel model. Results of the frequency analysis showed that the 1/R control tended to diverge when very low frequency band that was an indication of the vasomotion frequency was relative high. In numerical simulation, divergence of the 1/R control could be reproduced and the boundary curves between the divergence and convergence of the 1/R control varied depending on the control time constant. These results suggested that the 1/R control tended to be unstable when the TAH recipient had high reflex speed in the baroreflex vascular system. Therefore, the control time constant should be adjusted appropriately with the individual vasomotion frequency.

  15. Constant symplectic 2-groupoids

    NASA Astrophysics Data System (ADS)

    Mehta, Rajan Amit; Tang, Xiang

    2018-05-01

    We propose a definition of symplectic 2-groupoid which includes integrations of Courant algebroids that have been recently constructed. We study in detail the simple but illustrative case of constant symplectic 2-groupoids. We show that the constant symplectic 2-groupoids are, up to equivalence, in one-to-one correspondence with a simple class of Courant algebroids that we call constant Courant algebroids. Furthermore, we find a correspondence between certain Dirac structures and Lagrangian sub-2-groupoids.

  16. Unitaxial constant velocity microactuator

    DOEpatents

    McIntyre, Timothy J.

    1994-01-01

    A uniaxial drive system or microactuator capable of operating in an ultra-high vacuum environment. The mechanism includes a flexible coupling having a bore therethrough, and two clamp/pusher assemblies mounted in axial ends of the coupling. The clamp/pusher assemblies are energized by voltage-operated piezoelectrics therewithin to operatively engage the shaft and coupling causing the shaft to move along its rotational axis through the bore. The microactuator is capable of repeatably positioning to sub-manometer accuracy while affording a scan range in excess of 5 centimeters. Moreover, the microactuator generates smooth, constant velocity motion profiles while producing a drive thrust of greater than 10 pounds. The system is remotely controlled and piezoelectrically driven, hence minimal thermal loading, vibrational excitation, or outgassing is introduced to the operating environment.

  17. The VO(2)-on kinetics in constant load exercise sub-anaerobic threshold reflects endothelial function and dysfunction in muscle microcirculation.

    PubMed

    Maione, D; Cicero, A Fg; Bacchelli, S; Cosentino, E R; Degli Esposti, D; Manners, D N; Rinaldi, E R; Rosticci, M; Senaldi, R; Ambrosioni, E; Borghi, C

    2015-01-01

    To propose a test to evaluate endothelial function, based on VO(2) on-transition kinetics in sub-anaerobic threshold (AT) constant load exercise, we tested healthy subjects and patients with ischemic-hypertensive cardiopathy by two cardiopulmonary tests on a cycle ergometer endowed with an electric motor to overcome initial inertia: a pre-test and, after at least 24 h, one 6 min constant load exercise at 90 % AT. We measured net phase 3 VO(2)-on kinetics and, by phase 2 time constant (tau), valued endothelial dysfunction. We found shorter tau in repeated tests, shorter time between first and second test, by persisting endothelium-dependent arteriolar vasodilatation and/or several other mechanisms. Reducing load to 80 % and 90 % AT did not produce significant changes in tau of healthy volunteers, while in heart patients an AT load of 70 %, compared to 80 % AT, shortened tau (delta=4.38+/-1.65 s, p=0.013). In heart patients, no correlation was found between NYHA class, ejection fraction (EF), and the two variables derived from incremental cycle cardio-pulmonary exercise, as well as between EF and tau; while NYHA class groups were well correlated with tau duration (r=0.92, p=0.0001). Doxazosin and tadalafil also significantly reduced tau. In conclusion, the O(2) consumption kinetics during the on-transition of constant load exercise below the anaerobic threshold are highly sensitive to endothelial function in muscular microcirculation, and constitute a marker for the evaluation of endothelial dysfunction.

  18. Method for accurate determination of dissociation constants of optical ratiometric systems: chemical probes, genetically encoded sensors, and interacting molecules.

    PubMed

    Pomorski, Adam; Kochańczyk, Tomasz; Miłoch, Anna; Krężel, Artur

    2013-12-03

    Ratiometric chemical probes and genetically encoded sensors are of high interest for both analytical chemists and molecular biologists. Their high sensitivity toward the target ligand and ability to obtain quantitative results without a known sensor concentration have made them a very useful tool in both in vitro and in vivo assays. Although ratiometric sensors are widely used in many applications, their successful and accurate usage depends on how they are characterized in terms of sensing target molecules. The most important feature of probes and sensors besides their optical parameters is an affinity constant toward analyzed molecules. The literature shows that different analytical approaches are used to determine the stability constants, with the ratio approach being most popular. However, oversimplification and lack of attention to detail results in inaccurate determination of stability constants, which in turn affects the results obtained using these sensors. Here, we present a new method where ratio signal is calibrated for borderline values of intensities of both wavelengths, instead of borderline ratio values that generate errors in many studies. At the same time, the equation takes into account the cooperativity factor or fluorescence artifacts and therefore can be used to characterize systems with various stoichiometries and experimental conditions. Accurate determination of stability constants is demonstrated utilizing four known optical ratiometric probes and sensors, together with a discussion regarding other, currently used methods.

  19. Effective Torsion and Spring Constants in a Hybrid Translational-Rotational Oscillator

    ERIC Educational Resources Information Center

    Nakhoda, Zein; Taylor, Ken

    2011-01-01

    A torsion oscillator is a vibrating system that experiences a restoring torque given by [tau] = -[kappa][theta] when it experiences a rotational displacement [theta] from its equilibrium position. The torsion constant [kappa] (kappa) is analogous to the spring constant "k" for the traditional translational oscillator (for which the restoring force…

  20. The Physiology Constant Database of Teen-Agers in Beijing

    PubMed Central

    Wei-Qi, Wei; Guang-Jin, Zhu; Cheng-Li, Xu; Shao-Mei, Han; Bao-Shen, Qi; Li, Chen; Shu-Yu, Zu; Xiao-Mei, Zhou; Wen-Feng, Hu; Zheng-Guo, Zhang

    2004-01-01

    Physiology constants of adolescents are important to understand growing living systems and are a useful reference in clinical and epidemiological research. Until recently, physiology constants were not available in China and therefore most physiologists, physicians, and nutritionists had to use data from abroad for reference. However, the very difference between the Eastern and Western races casts doubt on the usefulness of overseas data. We have therefore created a database system to provide a repository for the storage of physiology constants of teen-agers in Beijing. The several thousands of pieces of data are now divided into hematological biochemistry, lung function, and cardiac function with all data manually checked before being transferred into the database. The database was accomplished through the development of a web interface, scripts, and a relational database. The physiology data were integrated into the relational database system to provide flexible facilities by using combinations of various terms and parameters. A web browser interface was designed for the users to facilitate their searching. The database is available on the web. The statistical table, scatter diagram, and histogram of the data are available for both anonym and user according to queries, while only the user can achieve detail, including download data and advanced search. PMID:15258669

  1. The equilibrium constant of complex formation in solution: A study utilizing a dielectric constant method

    NASA Astrophysics Data System (ADS)

    Loh, C. W.

    1980-03-01

    A method was developed for determining equilibrium constants, heat of reaction, and change in free energy and entropy during a 1:1 complex formation in solutions. The measurements were carried out on ternary systems containing two interacting solutes in an inert solvent. The procedures was applied to the investigation of hydrogen bond complex formations in two mixtures systems, phenol and pyridine in carbon tetrachloride, and 4, 5, 6, 7-tetrachloro-2-trifluoromethylbenzimidazole (TTFB) and alkyl acetate in styrene. The first mixture system was studied in order to compare the results with those obtained by other methods. Results for the second mixture system indicated strong association between molecules of TTFB and alkyl acetate and suggested that the blocking of valinomycin-mediated bilayer membrane conductance by substituted benzimidazoles was due to competition for a limited number of adsorption sites on the membrane surface.

  2. Nonadiabatic effects on the charge transfer rate constant: A numerical study of a simple model system

    NASA Astrophysics Data System (ADS)

    Shin, Seokmin; Metiu, Horia

    1995-06-01

    We use a minimal model to study the effects of the upper electronic states on the rate of a charge transfer reaction. The model consists of three ions and an electron, all strung on a line. The two ions at the ends of the structure are held fixed, but the middle ion and the electron are allowed to move in one dimension, along the line joining them. The system has two bound states, one in which the electron ties the movable ion to the fixed ion at the left, and the other in which the binding takes place to the fixed ion at the right. The transition between these bound states is a charge transfer reaction. We use the flux-flux correlation function theory to perform two calculations of the rate constant for this reaction. In one we obtain numerically the exact rate constant. In the other we calculate the exact rate constant for the case when the reaction proceeds exclusively on the ground adiabatic state. The difference between these calculations gives the magnitude of the nonadiabatic effects. We find that the nonadiabatic effects are fairly large even when the gap between the ground and the excited adiabatic state substantially exceeds the thermal energy. The rate in the nonadiabatic theory is always smaller than that of the adiabatic one. Both rate constants satisfy the Arrhenius formula. Their activation energies are very close but the nonadiabatic one is always higher. The nonadiabatic preexponential is smaller, due to the fact that the upper electronic state causes an early recrossing of the reactive flux. The description of this reaction in terms of two diabatic states, one for reactants and one for products, is not always adequate. In the limit when nonadiabaticity is small, we need to use a third diabatic state, in which the electron binds to the moving ion as the latter passes through the transition state; this is an atom transfer process. The reaction changes from an atom transfer to an electron transfer, as nonadiabaticity is increased.

  3. Rotational Spectra and Nuclear Quadrupole Coupling Constants of Iodoimidazoles

    NASA Astrophysics Data System (ADS)

    Cooper, Graham A.; Anderson, Cara J.; Medcraft, Chris; Legon, Anthony; Walker, Nick

    2017-06-01

    The microwave spectra of two isomers of iodoimidazole have been recorded and assigned with resolution of their nuclear quadrupole coupling constants. These constants have been analysed in terms of the conjugation between the lone pairs on the iodine atom and the aromatic π-bonding system, and the effect of this conjugation on the distribution of π-electron density in the ring. A comparison of these properties has been made between iodoimidazole and other 5- and 6-membered aromatic rings bonded to halogen atoms.

  4. ESTIMATION OF HYDROLYSIS RATE CONSTANTS OF CARBOXYLIC ACID ESTER AND PHOSPHATE ESTER COMPOUNDS IN AQUEOUS SYSTEMS FROM MOLECULAR STRUCTURE BY SPARC

    EPA Science Inventory

    SPARC (SPARC Performs Automated Reasoning in Chemistry) chemical reactivity models were extended to calculate hydrolysis rate constants for carboxylic acid ester and phosphate ester compounds in aqueous non- aqueous and systems strictly from molecular structure. The energy diffe...

  5. Water-based synthesis of zeolitic imidazolate framework-90 (ZIF-90) with a controllable particle size.

    PubMed

    Shieh, Fa-Kuen; Wang, Shao-Chun; Leo, Sin-Yen; Wu, Kevin C-W

    2013-08-19

    The ZIF code: ZIF-90 materials were successfully synthesized in an optimized water-based system. The particle size, ranging from micro- to nanoscales, could be controlled by different amounts of polyvinylpyrrolidone (PVP), Zn/imidazole-2-carboxaldehyde ratio and alcohol. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Interaction of Strontium-90 in Sediment and Porewater in a Stream Near Chernobyl

    NASA Astrophysics Data System (ADS)

    Freed, R.; Smith, L.; Bugai, D.

    2002-12-01

    We investigated the interaction of 90Sr in sediments and pore waters of wetlands and stream hyporheic zones at a stream near Chernobyl. A non-dimensional activity ratio was formulated, the ratio of 90Sr in the pore waters compared with exchangeable 90Sr in the sediment on a volume basis. The average activity ratio for the wetland and channel sediments was 0.028 +/- 0.005. The activity ratio decreased when the sediment and porewaters were not in equilibrium. The change in the activity ratio was documented during two observational periods in a wetland: initially during a time when groundwater was discharging to the wetland (snowmelt, 2000) and subsequently at a time of near-stagnant groundwater flow (late fall in 2001 after a dry three month period). In both the discharge and stagnant periods, the exchangeable 90Sr concentration in sediment increased with depth by a factor of five to a peak concentration at 10 cm. In contrast, the 90Sr concentration in porewater differed significantly in the two observational periods. During the groundwater discharge period, the porewater concentration was relatively constant over the 30 cm depth of observation (120 +/-12 Bq/L) and surface water concentrations were similar. During the near-stagnant period, the porewater concentration increased with depth from 20+/-2 Bq/L in surface waters to 400 +/-40 Bq/L at a depth of 10 cm. We hypothesize that during discharge periods, the porewaters in the wetland represent the 90Sr concentration of advecting groundwater while during stagnant periods, the porewaters represent the concentration of 90Sr in equilibrium with the sediment. This proposed explanation is supported using PHREEQC in a dual porosity mode. Using independent estimates of the model parameters, the concentration profiles could be successfully matched with the assumption of advective transport during the discharge period and diffusive transport of 90Sr during near-stagnant conditions.

  7. 30 CFR 90.3 - Part 90 option; notice of eligibility; exercise of option.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Part 90 option; notice of eligibility; exercise of option. 90.3 Section 90.3 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... DEVELOPMENT OF PNEUMOCONIOSIS General § 90.3 Part 90 option; notice of eligibility; exercise of option. (a...

  8. Cantilever spring constant calibration using laser Doppler vibrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ohler, Benjamin

    2007-06-15

    Uncertainty in cantilever spring constants is a critical issue in atomic force microscopy (AFM) force measurements. Though numerous methods exist for calibrating cantilever spring constants, the accuracy of these methods can be limited by both the physical models themselves as well as uncertainties in their experimental implementation. Here we report the results from two of the most common calibration methods, the thermal tune method and the Sader method. These were implemented on a standard AFM system as well as using laser Doppler vibrometry (LDV). Using LDV eliminates some uncertainties associated with optical lever detection on an AFM. It also offersmore » considerably higher signal to noise deflection measurements. We find that AFM and LDV result in similar uncertainty in the calibrated spring constants, about 5%, using either the thermal tune or Sader methods provided that certain limitations of the methods and instrumentation are observed.« less

  9. 41 CFR 300-90.6 - What is authorized under the test programs?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the test programs? 300-90.6 Section 300-90.6 Public Contracts and Property Management Federal Travel Regulation System GENERAL AGENCY REQUIREMENTS 90-TELEWORK TRAVEL EXPENSES TEST PROGRAMS § 300-90.6 What is authorized under the test programs? Under a telework expenses test program authorized by the Administrator of...

  10. 41 CFR 300-90.7 - What is the duration of test programs?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 41 Public Contracts and Property Management 4 2014-07-01 2014-07-01 false What is the duration of test programs? 300-90.7 Section 300-90.7 Public Contracts and Property Management Federal Travel Regulation System GENERAL AGENCY REQUIREMENTS 90-TELEWORK TRAVEL EXPENSES TEST PROGRAMS § 300-90.7 What is...

  11. Analysis of a dc bus system with a nonlinear constant power load and its delayed feedback control.

    PubMed

    Konishi, Keiji; Sugitani, Yoshiki; Hara, Naoyuki

    2014-02-01

    This paper tackles a destabilizing problem of a direct-current (dc) bus system with constant power loads, which can be considered a fundamental problem of dc power grid networks. The present paper clarifies scenarios of the destabilization and applies the well-known delayed-feedback control to the stabilization of the destabilized bus system on the basis of nonlinear science. Further, we propose a systematic procedure for designing the delayed feedback controller. This controller can converge the bus voltage exactly on an unstable operating point without accurate information and can track it using tiny control energy even when a system parameter, such as the power consumption of the load, is slowly varied. These features demonstrate that delayed feedback control can be considered a strong candidate for solving the destabilizing problem.

  12. Determination of stability constants of aminoglycoside antibiotics with their metal complexes

    NASA Astrophysics Data System (ADS)

    Tiwow, Vanny M. A.

    2014-03-01

    One group of aminoglycoside antibiotics contains aminosugars. The aminosugar neomycin B with its derivate product neamine (2-Deoxy-4-0-(2,6-diamino-2,6-dideoxy-α-D-glucopyranosyl)-D-Streptamine) was identified as a free ligands and metal complexes. In particular, the stability constants of metal complexes by potentiometric titration techniques were investigated. Our previous study had determined the acid dissociation constants of these aminosugars with few metal complexes in fair depth. In this work, the complexation of two pyridine-containing amino alcohols and an amino sugar (neamine) have been measured potentiometrically. For instance, the stability constant of copper(II) complexation were determine and the model system generated an excellent fit. Stability constants with several metals have been determined and will be reported.

  13. H0, q0 and the local velocity field. [Hubble and deceleration constants in Big Bang expansion

    NASA Technical Reports Server (NTRS)

    Sandage, A.; Tammann, G. A.

    1982-01-01

    An attempt is made to find a systematic deviation from linearity for distances that are under the control of the Virgo cluster, and to determine the value of the mean random motion about the systematic flow, in order to improve the measurement of the Hubble and the deceleration constants. The velocity-distance relation for large and intermediate distances is studied, and type I supernovae are calibrated relatively as distance indicators and absolutely to obtain a new value for the Hubble constant. Methods of determining the deceleration constant are assessed, including determination from direct measurement, mean luminosity density, virgocentric motion, and the time scale test. The very local velocity field is investigated, and a solution is preferred with a random peculiar radial velocity of very nearby field galaxies of 90-100 km/s, and a Virgocentric motion of the local group of 220 km/s, leading to an underlying expansion rate of 55, in satisfactory agreement with the global value.

  14. Comparison of entrainment in constant volume and constant flux dense currents over sloping bottoms

    NASA Astrophysics Data System (ADS)

    Bhaganagar, K.; Nayamatullah, M.; Cenedese, C.

    2014-12-01

    Three dimensional high resolution large eddy simulations (LES) are employed to simulate lock-exchange and constant flux dense flows over inclined surface with the aim of investigating, visualizing and describing the turbulent structure and the evolution of bottom-propagating compositional density current at the channel bottom. The understanding of dynamics of density current is largely determined by the amount of interfacial mixing or entrainment between the ambient and dense fluids. No previous experimental or numerical studies have been done to estimate entrainment in classical lock-exchange system. The differences in entrainment between the lock-exchange and constant flux are explored. Comparing the results of flat bed with inclined surface results, flow exhibits significant differences near the leading edge or nose of the front of the density currents due to inclination of surface. Further, the instabilities are remarkably enhanced resulting Kelvin-Helmholtz and lobe-cleft type of instabilities arises much earlier in time. In this study, a brief analysis of entrainment on lock-exchange density current is presented using different bed slopes and a set of reduced gravity values (g'). We relate the entrainment value with different flow parameters such as Froude number (Fr) and Reynolds number (Re).

  15. Instanton rate constant calculations close to and above the crossover temperature.

    PubMed

    McConnell, Sean; Kästner, Johannes

    2017-11-15

    Canonical instanton theory is known to overestimate the rate constant close to a system-dependent crossover temperature and is inapplicable above that temperature. We compare the accuracy of the reaction rate constants calculated using recent semi-classical rate expressions to those from canonical instanton theory. We show that rate constants calculated purely from solving the stability matrix for the action in degrees of freedom orthogonal to the instanton path is not applicable at arbitrarily low temperatures and use two methods to overcome this. Furthermore, as a by-product of the developed methods, we derive a simple correction to canonical instanton theory that can alleviate this known overestimation of rate constants close to the crossover temperature. The combined methods accurately reproduce the rate constants of the canonical theory along the whole temperature range without the spurious overestimation near the crossover temperature. We calculate and compare rate constants on three different reactions: H in the Müller-Brown potential, methylhydroxycarbene → acetaldehyde and H 2  + OH → H + H 2 O. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  16. Imaging nanoclusters in the constant height mode of the dynamic SFM.

    PubMed

    Barth, Clemens; Pakarinen, Olli H; Foster, Adam S; Henry, Claude R

    2006-04-14

    For the first time, high quality images of metal nanoclusters which were recorded in the constant height mode of a dynamic scanning force microscope (dynamic SFM) are shown. Surfaces of highly ordered pyrolytic graphite (HOPG) were used as a test substrate since metal nanoclusters with well defined and symmetric shapes can be created by epitaxial growth. We performed imaging of gold clusters with sizes between 5 and 15 nm in both scanning modes, constant Δf mode and constant height mode, and compared the image contrast. We notice that clusters in constant height images appear much sharper, and exhibit more reasonable lateral shapes and sizes in comparison to images recorded in the constant Δf mode. With the help of numerical simulations we show that only a microscopically small part of the tip apex (nanotip) is probably the main contributor for the image contrast formation. In principle, the constant height mode can be used for imaging surfaces of any material, e.g. ionic crystals, as shown for the system Au/NaCl(001).

  17. Cosmological Constant as a Manifestation of the Hierarchy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Pisin; Gu, Je-An

    2007-12-21

    There has been the suggestion that the cosmological constant as implied by the dark energy is related to the well-known hierarchy between the Planck scale, M{sub PI}, and the Standard Model scale, M{sub SM}. Here we further propose that the same framework that addresses this hierarchy problem must also address the smallness problem of the cosmological constant. Specifically, we investigate the minimal supersymmetric (SUSY) extension of the Randall-Sundrum model where SUSY-breaking is induced on the TeV brane and transmitted into the bulk. We show that the Casimir energy density of the system indeed conforms with the observed dark energy scale.

  18. Automated real time constant-specificity surveillance for disease outbreaks.

    PubMed

    Wieland, Shannon C; Brownstein, John S; Berger, Bonnie; Mandl, Kenneth D

    2007-06-13

    For real time surveillance, detection of abnormal disease patterns is based on a difference between patterns observed, and those predicted by models of historical data. The usefulness of outbreak detection strategies depends on their specificity; the false alarm rate affects the interpretation of alarms. We evaluate the specificity of five traditional models: autoregressive, Serfling, trimmed seasonal, wavelet-based, and generalized linear. We apply each to 12 years of emergency department visits for respiratory infection syndromes at a pediatric hospital, finding that the specificity of the five models was almost always a non-constant function of the day of the week, month, and year of the study (p < 0.05). We develop an outbreak detection method, called the expectation-variance model, based on generalized additive modeling to achieve a constant specificity by accounting for not only the expected number of visits, but also the variance of the number of visits. The expectation-variance model achieves constant specificity on all three time scales, as well as earlier detection and improved sensitivity compared to traditional methods in most circumstances. Modeling the variance of visit patterns enables real-time detection with known, constant specificity at all times. With constant specificity, public health practitioners can better interpret the alarms and better evaluate the cost-effectiveness of surveillance systems.

  19. 47 CFR 90.363 - Grandfathering provisions for existing AVM licensees.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Grandfathering provisions for existing AVM licensees. 90.363 Section 90.363 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Intelligent Transportation Systems Radio Service...

  20. 47 CFR 90.476 - Interconnection of fixed stations and certain mobile stations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... mobile stations. 90.476 Section 90.476 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Interconnected Systems § 90.476 Interconnection of fixed stations and certain mobile stations. (a) Fixed stations and...

  1. An original approach to elastic constants determination using a self-developed EMAT system

    NASA Astrophysics Data System (ADS)

    Jenot, Frédéric; Rivart, Frédéric; Camus, Liévin

    2018-04-01

    Electromagnetic Acoustic Transducers (EMATs) allow non-contact ultrasonic measurements in order to characterize structures for a wide range of applications. Considering non-ferromagnetic metal materials, excitation of elastic waves is due to Lorentz forces that result from an applied magnetic field and induced eddy currents in a near surface region of the sample. EMAT's design is based on a magnet structure associated with a coil leading to multiple configurations, which are able to excite bulk and guided acoustic waves. In this work, we first present a self-developed EMAT system composed of multiple emission and reception channels. In a second part, we propose an original method in order to determine the elastic constants of an isotropic material. To achieve this goal, Rayleigh and shear waves are used and the advantages of this method are clearly highlighted. The results obtained are then compared with conventional measurements achieved with piezoelectric transducers.

  2. The uptake of plutonium-238, 239, 240, americium-241, strontium-90 and caesium-137 into potatoes.

    PubMed

    Popplewell, D S; Ham, G J; Johnson, T E; Stather, J W; Sumner, S A

    1984-09-01

    Transfer factors have been measured for 239 Pu + 240 Pu, 241 Am, 90 Sr and 137 Cs into potatoes grown in a blend of soil which included silt polluted with radioactive waste discharged into the Irish Sea. The experiment has been carried out over four seasons and attempts to assess the radiological consequences to the consumer which would arise if potatoes were to be grown in land heavily contaminated with the silt. During the course of the experiment plutonium and americium became less available for uptake, 90 Sr became slightly more available and 137 Cs remained nearly constant in its availability. The values of the transfer factors are among the lowest reported for these radionuclides into potatoes.

  3. 36 CFR 1202.90 - What NARA systems of records are exempt from release under the National Security Exemption of the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... of the Inspector General (NARA-23) and the Personnel Security Case Files (NARA-24) systems of records... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false What NARA systems of records are exempt from release under the National Security Exemption of the Privacy Act? 1202.90 Section 1202...

  4. Units Based on Constants: The Redefinition of the International System of Units

    NASA Astrophysics Data System (ADS)

    Stenger, J.; Ullrich, J. H.

    2016-03-01

    Recent decisions of the General Conference on Weights and Measures of the Metre Convention have opened the door to a fundamental change of the International System of Units, the SI, in 2018. The revised SI will be based on fixing the numerical values of seven defining constants corresponding to the seven traditional base units. This will bring about basic modifications in the definition of the kilogram, the ampere, the kelvin, and the mole and will have consequences for units derived from them. In contrast, the second, the meter, and the candela will not be affected. This paper describes the motivation and rationale behind this endeavor, introduces the new definitions, and reviews the requirements for the redefinitions as well as the status of the experiments that are currently being carried out to fulfill them. Benefits and a wide-reaching impact for the realization and dissemination of the units are anticipated because innovative technologies with ever-increasing accuracy will emerge, enabling the direct realization over widespread measurement ranges without the definitions themselves having to be changed.

  5. 12 CFR 222.90 - Duties regarding the detection, prevention, and mitigation of identity theft.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... mitigation of identity theft. 222.90 Section 222.90 Banks and Banking FEDERAL RESERVE SYSTEM (CONTINUED) BOARD OF GOVERNORS OF THE FEDERAL RESERVE SYSTEM FAIR CREDIT REPORTING (REGULATION V) Identity Theft Red Flags § 222.90 Duties regarding the detection, prevention, and mitigation of identity theft. (a) Scope...

  6. 12 CFR 222.90 - Duties regarding the detection, prevention, and mitigation of identity theft.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... mitigation of identity theft. 222.90 Section 222.90 Banks and Banking FEDERAL RESERVE SYSTEM (CONTINUED) BOARD OF GOVERNORS OF THE FEDERAL RESERVE SYSTEM FAIR CREDIT REPORTING (REGULATION V) Identity Theft Red Flags § 222.90 Duties regarding the detection, prevention, and mitigation of identity theft. (a) Scope...

  7. Weak signal detection: A discrete window of opportunity for achieving 'Vision 90:90:90'?

    PubMed

    Burman, Christopher J; Aphane, Marota; Delobelle, Peter

    2016-01-01

    UNAIDS' Vision 90:90:90 is a call to 'end AIDS'. Developing predictive foresight of the unpredictable changes that this journey will entail could contribute to the ambition of 'ending AIDS'. There are few opportunities for managing unpredictable changes. We introduce 'weak signal detection' as a potential opportunity to fill this void. Combining futures and complexity theory, we reflect on two pilot case studies that involved the Archetype Extraction technique and the SenseMaker(®) Collector(™) tool. Both the piloted techniques have the potentials to surface weak signals--but there is room for improvement. A management response to a complex weak signal requires pattern management, rather than an exclusive focus on behaviour management. Weak signal detection is a window of opportunity to improve resilience to unpredictable changes in the HIV/AIDS landscape that can both reduce the risk that emerges from the changes and increase the visibility of opportunities to exploit the unpredictable changes that could contribute to 'ending AIDS'.

  8. On the validity of specific rate constants (kSA) in Fe0/H2O systems.

    PubMed

    Noubactep, C

    2009-05-30

    The validity of the specific reaction rate constants (k(SA)) in modelling contaminant removal in Fe(0)/H(2)O systems is questioned. It is shown that the current k(SA)-model does not consider the large reactive surface area provided by the in-situ formed oxide film, and thus the adsorptive interactions between contaminants and film materials. Furthermore, neither the dynamic nature of film formation nor the fact that the Fe(0) surface is shielded by the film is considered. Suggestions are made how the k(SA)-model could be further developed to meet its original goal.

  9. Program operational summary: Operational 90 day manned test of a regenerative life support system

    NASA Technical Reports Server (NTRS)

    Jackson, J. K.; Wamsley, J. R.; Bonura, M. S.; Seeman, J. S.

    1972-01-01

    An operational 90-day manned test of a regenerative life support system was successfully completed. This test was performed with a crew of four carefully selected and trained men in a space station simulator (SSS) which had a two gas atmosphere maintained at a total pressure of 68.9, 10 psia, and composed of oxygen at a partial pressure of 3.05 psia with nitrogen as the diluent. The test was planned to provide data on regenerative life support subsystems and on integrated system operations in a closed ecology, similar to that of a space station. All crew equipment and expendables were stored onboard at the start of the mission to eliminate the need for pass-in operations. The significant accomplishments of the test, some of the pertinent test results, some of the problem areas, and conclusions are presented.

  10. 47 CFR 90.351 - Location and Monitoring Service.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of mobile radio units. LMS licensees authorized to operate a system in the 902-928 MHz band may serve... SERVICES PRIVATE LAND MOBILE RADIO SERVICES Intelligent Transportation Systems Radio Service § 90.351... description of the manner in which the system will operate, including a map or diagram. (2) The necessary or...

  11. Influence of Joint Angle on EMG-Torque Model During Constant-Posture, Torque-Varying Contractions.

    PubMed

    Liu, Pu; Liu, Lukai; Clancy, Edward A

    2015-11-01

    Relating the electromyogram (EMG) to joint torque is useful in various application areas, including prosthesis control, ergonomics and clinical biomechanics. Limited study has related EMG to torque across varied joint angles, particularly when subjects performed force-varying contractions or when optimized modeling methods were utilized. We related the biceps-triceps surface EMG of 22 subjects to elbow torque at six joint angles (spanning 60° to 135°) during constant-posture, torque-varying contractions. Three nonlinear EMG σ -torque models, advanced EMG amplitude (EMG σ ) estimation processors (i.e., whitened, multiple-channel) and the duration of data used to train models were investigated. When EMG-torque models were formed separately for each of the six distinct joint angles, a minimum "gold standard" error of 4.01±1.2% MVC(F90) resulted (i.e., error relative to maximum voluntary contraction at 90° flexion). This model structure, however, did not directly facilitate interpolation across angles. The best model which did so achieved a statistically equivalent error of 4.06±1.2% MVC(F90). Results demonstrated that advanced EMG σ processors lead to improved joint torque estimation as do longer model training durations.

  12. Tachyon constant-roll inflation

    NASA Astrophysics Data System (ADS)

    Mohammadi, A.; Saaidi, Kh.; Golanbari, T.

    2018-04-01

    The constant-roll inflation is studied where the inflaton is taken as a tachyon field. Based on this approach, the second slow-roll parameter is taken as a constant which leads to a differential equation for the Hubble parameter. Finding an exact solution for the Hubble parameter is difficult and leads us to a numerical solution for the Hubble parameter. On the other hand, since in this formalism the slow-roll parameter η is constant and could not be assumed to be necessarily small, the perturbation parameters should be reconsidered again which, in turn, results in new terms appearing in the amplitude of scalar perturbations and the scalar spectral index. Utilizing the numerical solution for the Hubble parameter, we estimate the perturbation parameter at the horizon exit time and compare it with observational data. The results show that, for specific values of the constant parameter η , we could have an almost scale-invariant amplitude of scalar perturbations. Finally, the attractor behavior for the solution of the model is presented, and we determine that the feature could be properly satisfied.

  13. Accurate L-Band Measurements of the Dielectric Constant of Seawater

    NASA Technical Reports Server (NTRS)

    Lang, R.H.; Utku, C.; Tarkocin, Y.; Vine, D.M. Le

    2007-01-01

    A new temperature controlled microwave cavity system to measure the complex dielectric constant of seawater at 1.413 GHz is discussed. The system is being developed to measure seawater for temperatures from O C to 30 C and salinities from 10 to 40 psu, The paper discusses the construction of the measurement system and initial stability tests.

  14. Improved measurement of B(D+ --> mu+nu) and the pseudoscalar decay constant fD+.

    PubMed

    Artuso, M; Boulahouache, C; Blusk, S; Butt, J; Dorjkhaidav, O; Li, J; Menaa, N; Mountain, R; Nandakumar, R; Randrianarivony, K; Redjimi, R; Sia, R; Skwarnicki, T; Stone, S; Wang, J C; Zhang, K; Csorna, S E; Bonvicini, G; Cinabro, D; Dubrovin, M; Lincoln, A; Briere, R A; Chen, G P; Chen, J; Ferguson, T; Tatishvili, G; Vogel, H; Watkins, M E; Rosner, J L; Adam, N E; Alexander, J P; Berkelman, K; Cassel, D G; Crede, V; Duboscq, J E; Ecklund, K M; Ehrlich, R; Fields, L; Gibbons, L; Gittelman, B; Gray, R; Gray, S W; Hartill, D L; Heltsley, B K; Hertz, D; Jones, C D; Kandaswamy, J; Kreinick, D L; Kuznetsov, V E; Mahlke-Krüger, H; Meyer, T O; Onyisi, P U E; Patterson, J R; Peterson, D; Phillips, E A; Pivarski, J; Riley, D; Ryd, A; Sadoff, A J; Schwarthoff, H; Shi, X; Shepherd, M R; Stroiney, S; Sun, W M; Urner, D; Wilksen, T; Weaver, K M; Weinberger, M; Athar, S B; Avery, P; Breva-Newell, L; Patel, R; Potlia, V; Stoeck, H; Yelton, J; Rubin, P; Cawlfield, C; Eisenstein, B I; Gollin, G D; Karliner, I; Kim, D; Lowrey, N; Naik, P; Sedlack, C; Selen, M; White, E J; Williams, J; Wiss, J; Asner, D M; Edwards, K W; Besson, D; Pedlar, T K; Cronin-Hennessy, D; Gao, K Y; Gong, D T; Hietala, J; Kubota, Y; Klein, T; Lang, B W; Li, S Z; Poling, R; Scott, A W; Smith, A; Dobbs, S; Metreveli, Z; Seth, K K; Tomaradze, A; Zweber, P; Ernst, J; Severini, H; Dytman, S A; Love, W; Mehrabyan, S; Mueller, J A; Savinov, V; Li, Z; Lopez, A; Mendez, H; Ramirez, J; Huang, G S; Miller, D H; Pavlunin, V; Sanghi, B; Shipsey, I P J; Adams, G S; Anderson, M; Cummings, J P; Danko, I; Napolitano, J; He, Q; Muramatsu, H; Park, C S; Thorndike, E H; Coan, T E; Gao, Y S; Liu, F

    2005-12-16

    We extract a relatively precise value for the decay constant of the meson by measuring B(D+ --> mu+nu) = (4.40 +/-0.66(+0.09)(-0.12) x 10(-4) using 281 pb(-1) of data taken on phi(3770) the resonance with the CLEO-c detector. We find fD+ = (222.6 +/- 16.7(+2.8)(-3.4)) MeV, and compare with current theoretical calculations. We also set a 90% confidence upper limit on B(D+e+nu)< 2.4 x 10(-5) which constrains new physics models.

  15. THE MILLIMETER ASTRONOMY LEGACY TEAM 90 GHz (MALT90) PILOT SURVEY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Foster, Jonathan B.; Jackson, James M.; Barris, Elizabeth

    We describe a pilot survey conducted with the Mopra 22 m radio telescope in preparation for the Millimeter Astronomy Legacy Team Survey at 90 GHz (MALT90). We identified 182 candidate dense molecular clumps using six different selection criteria and mapped each source simultaneously in 16 different lines near 90 GHz. We present a summary of the data and describe how the results of the pilot survey shaped the design of the larger MALT90 survey. We motivate our selection of target sources for the main survey based on the pilot detection rates and demonstrate the value of mapping in multiple linesmore » simultaneously at high spectral resolution.« less

  16. Life History Characteristics of Frankliniella occidentalis and Frankliniella intonsa (Thysanoptera: Thripidae) in Constant and Fluctuating Temperatures.

    PubMed

    Ullah, Mohammad Shaef; Lim, Un Taek

    2015-06-01

    Frankliniella occidentalis (Pergande) and Frankliniella intonsa (Trybom) are sympatric pests of many greenhouse and field crops in Korea. We compared the influence of constant (27.3°C) and fluctuating temperatures (23.8-31.5°C, with an average of 27.3°C) on the life table characteristics of F. occidentalis and F. intonsa held at a photoperiod of 16:8 (L:D) h and 45±5% relative humidity. The development times of both F. occidentalis and F. intonsa were significantly affected by temperature fluctuation, species, and sex. The development time from egg to adult of F. intonsa was shorter than that for F. occidentalis at both constant and fluctuating temperatures. Survival of immature life stages was higher under fluctuating than constant temperature for both thrips species. The total and daily production of first instars was higher in F. intonsa (90.4 and 4.2 at constant temperature, and 95.7 and 3.9 at fluctuating temperatures) than that of F. occidentalis (58.7 and 3.3 at constant temperature, and 60.5 and 3.1 at fluctuating temperatures) under both constant and fluctuating temperatures. The percentage of female offspring was greater in F. intonsa (72.1-75.7%) than in F. occidentalis (57.4-58.7%) under both temperature regimes. The intrinsic rate of natural increase (rm) was higher at constant temperature than at fluctuating temperature for both thrips species. F. intonsa had a higher rm value (0.2146 and 0.2004) than did F. occidentalis (0.1808 and 0.1733), under both constant and fluctuating temperatures, respectively. The biological response of F. occidentalis and F. intonsa to constant and fluctuating temperature was found to be interspecifically different, and F. intonsa may have higher pest potential than F. occidentalis based on the life table parameters we are reporting first here. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Cosmological dynamics with non-minimally coupled scalar field and a constant potential function

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hrycyna, Orest; Szydłowski, Marek, E-mail: orest.hrycyna@ncbj.gov.pl, E-mail: marek.szydlowski@uj.edu.pl

    2015-11-01

    Dynamical systems methods are used to investigate global behaviour of the spatially flat Friedmann-Robertson-Walker cosmological model in gravitational theory with a non-minimally coupled scalar field and a constant potential function. We show that the system can be reduced to an autonomous three-dimensional dynamical system and additionally is equipped with an invariant manifold corresponding to an accelerated expansion of the universe. Using this invariant manifold we find an exact solution of the reduced dynamics. We investigate all solutions for all admissible initial conditions using theory of dynamical systems to obtain a classification of all evolutional paths. The right-hand sides of themore » dynamical system depend crucially on the value of the non-minimal coupling constant therefore we study bifurcation values of this parameter under which the structure of the phase space changes qualitatively. We found a special bifurcation value of the non-minimal coupling constant which is distinguished by dynamics of the model and may suggest some additional symmetry in matter sector of the theory.« less

  18. 47 CFR 90.767 - Construction and implementation of EA and Regional licenses.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Regional licenses. 90.767 Section 90.767 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED... Use of Frequencies in the 220-222 MHz Band Policies Governing the Licensing and Use of Phase II Ea, Regional and Nationwide Systems § 90.767 Construction and implementation of EA and Regional licenses. (a...

  19. 40 CFR 86.1310-90 - Exhaust gas sampling and analytical system; diesel engines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the port entrance to the analyzer to within 90 percent of the step change. (B) 20 seconds from an instantaneous step change at the entrance to the sample probe or overflow span gas port to within 90 percent of... avoid moisture condensation. A filter pair loading of 1 mg is typically proportional to a 0.1 g/bhp-hr...

  20. 40 CFR 86.1310-90 - Exhaust gas sampling and analytical system; diesel engines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the port entrance to the analyzer to within 90 percent of the step change. (B) 20 seconds from an instantaneous step change at the entrance to the sample probe or overflow span gas port to within 90 percent of... avoid moisture condensation. A filter pair loading of 1 mg is typically proportional to a 0.1 g/bhp-hr...

  1. Elastic constants of stressed and unstressed materials in the phase-field crystal model

    NASA Astrophysics Data System (ADS)

    Wang, Zi-Le; Huang, Zhi-Feng; Liu, Zhirong

    2018-04-01

    A general procedure is developed to investigate the elastic response and calculate the elastic constants of stressed and unstressed materials through continuum field modeling, particularly the phase-field crystal (PFC) models. It is found that for a complete description of system response to elastic deformation, the variations of all the quantities of lattice wave vectors, their density amplitudes (including the corresponding anisotropic variation and degeneracy breaking), the average atomic density, and system volume should be incorporated. The quantitative and qualitative results of elastic constant calculations highly depend on the physical interpretation of the density field used in the model, and also importantly, on the intrinsic pressure that usually pre-exists in the model system. A formulation based on thermodynamics is constructed to account for the effects caused by constant pre-existing stress during the homogeneous elastic deformation, through the introducing of a generalized Gibbs free energy and an effective finite strain tensor used for determining the elastic constants. The elastic properties of both solid and liquid states can be well produced by this unified approach, as demonstrated by an analysis for the liquid state and numerical evaluations for the bcc solid phase. The numerical calculations of bcc elastic constants and Poisson's ratio through this method generate results that are consistent with experimental conditions, and better match the data of bcc Fe given by molecular dynamics simulations as compared to previous work. The general theory developed here is applicable to the study of different types of stressed or unstressed material systems under elastic deformation.

  2. 41 CFR 300-90.9 - What reports are required for a test program?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... required for a test program? 300-90.9 Section 300-90.9 Public Contracts and Property Management Federal Travel Regulation System GENERAL AGENCY REQUIREMENTS 90-TELEWORK TRAVEL EXPENSES TEST PROGRAMS § 300-90.9 What reports are required for a test program? (a) The Administrator of General Services must submit to...

  3. Calculation of Weibull strength parameters, Batdorf flaw density constants and related statistical quantities using PC-CARES

    NASA Technical Reports Server (NTRS)

    Szatmary, Steven A.; Gyekenyesi, John P.; Nemeth, Noel N.

    1990-01-01

    This manual describes the operation and theory of the PC-CARES (Personal Computer-Ceramic Analysis and Reliability Evaluation of Structures) computer program for the IBM PC and compatibles running PC-DOS/MS-DOR OR IBM/MS-OS/2 (version 1.1 or higher) operating systems. The primary purpose of this code is to estimate Weibull material strength parameters, the Batdorf crack density coefficient, and other related statistical quantities. Included in the manual is the description of the calculation of shape and scale parameters of the two-parameter Weibull distribution using the least-squares analysis and maximum likelihood methods for volume- and surface-flaw-induced fracture in ceramics with complete and censored samples. The methods for detecting outliers and for calculating the Kolmogorov-Smirnov and the Anderson-Darling goodness-of-fit statistics and 90 percent confidence bands about the Weibull line, as well as the techniques for calculating the Batdorf flaw-density constants are also described.

  4. Numerical results on the transcendence of constants involving pi, e, and Euler's constant

    NASA Technical Reports Server (NTRS)

    Bailey, David H.

    1988-01-01

    The existence of simple polynomial equations (integer relations) for the constants e/pi, e + pi, log pi, gamma (Euler's constant), e exp gamma, gamma/e, gamma/pi, and log gamma is investigated by means of numerical computations. The recursive form of the Ferguson-Fourcade algorithm (Ferguson and Fourcade, 1979; Ferguson, 1986 and 1987) is implemented on the Cray-2 supercomputer at NASA Ames, applying multiprecision techniques similar to those described by Bailey (1988) except that FFTs are used instead of dual-prime-modulus transforms for multiplication. It is shown that none of the constants has an integer relation of degree eight or less with coefficients of Euclidean norm 10 to the 9th or less.

  5. Constant-Pressure Hydraulic Pump

    NASA Technical Reports Server (NTRS)

    Galloway, C. W.

    1982-01-01

    Constant output pressure in gas-driven hydraulic pump would be assured in new design for gas-to-hydraulic power converter. With a force-multiplying ring attached to gas piston, expanding gas would apply constant force on hydraulic piston even though gas pressure drops. As a result, pressure of hydraulic fluid remains steady, and power output of the pump does not vary.

  6. Diffusional falsification of kinetic constants on Lineweaver-Burk plots.

    PubMed

    Ghim, Y S; Chang, H N

    1983-11-07

    The effect of mass transfer resistances on the Lineweaver-Burk plots in immobilized enzyme systems has been investigated numerically and with analytical approximate solutions. While Hamilton, Gardner & Colton (1974) studied the effect of internal diffusion resistances in planar geometry, our study was extended to the combined effect of internal and external diffusion in cylindrical and spherical geometries as well. The variation of Lineweaver-Burk plots with respect to the geometries was minimized by modifying the Thiele modulus and the Biot number with the shape factor. Especially for a small Biot number all the three Lineweaver-Burk plots fell on a single line. As was discussed by Hamilton et al. (1974), the curvature of the line for large external diffusion resistances was small enough to be assumed linear, which was confirmed from the two approximate solutions for large and small substrate concentrations. Two methods for obtaining intrinsic kinetic constants were proposed: First, we obtained both maximum reaction rate and Michaelis constant by fitting experimental data to a straight line where external diffusion resistance was relatively large, and second, we obtained Michaelis constant from apparent Michaelis constant from the figure in case we knew maximum reaction rate a priori.

  7. Schwarzian derivative treatment of the quantum second-order supersymmetry anomaly, and coupling-constant metamorphosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plyushchay, Mikhail S., E-mail: mikhail.plyushchay@usach.cl

    A canonical quantization scheme applied to a classical supersymmetric system with quadratic in momentum supercharges gives rise to a quantum anomaly problem described by a specific term to be quadratic in Planck constant. We reveal a close relationship between the anomaly and the Schwarzian derivative, and specify a quantization prescription which generates the anomaly-free supersymmetric quantum system with second order supercharges. We also discuss the phenomenon of a coupling-constant metamorphosis that associates quantum systems with the first-order supersymmetry to the systems with the second-order supercharges.

  8. Fundamental constants and high-resolution spectroscopy

    NASA Astrophysics Data System (ADS)

    Bonifacio, P.; Rahmani, H.; Whitmore, J. B.; Wendt, M.; Centurion, M.; Molaro, P.; Srianand, R.; Murphy, M. T.; Petitjean, P.; Agafonova, I. I.; D'Odorico, S.; Evans, T. M.; Levshakov, S. A.; Lopez, S.; Martins, C. J. A. P.; Reimers, D.; Vladilo, G.

    2014-01-01

    Absorption-line systems detected in high resolution quasar spectra can be used to compare the value of dimensionless fundamental constants such as the fine-structure constant, α, and the proton-to-electron mass ratio, μ = m_p/m_e, as measured in remote regions of the Universe to their value today on Earth. In recent years, some evidence has emerged of small temporal and also spatial variations in α on cosmological scales which may reach a fractional level of ≈ 10 ppm (parts per million). We are conducting a Large Programme of observations with the Very Large Telescope's Ultraviolet and Visual Echelle Spectrograph (UVES), and are obtaining high-resolution ({R ≈ 60 000}) and high signal-to-noise ratio (S/N ≈ 100) spectra calibrated specifically to study the variations of the fundamental constants. We here provide a general overview of the Large Programme and report on the first results for these two constants, discussed in detail in Molaro et al. (2013) and Rahmani et al. (2013). A stringent bound for Δα/α is obtained for the absorber at z_abs = 1.6919 towards HE 2217-2818. The absorption profile is complex with several very narrow features, and is modeled with 32 velocity components. The relative variation in α in this system is +1.3± 2.4_stat ± 1.0_sys ppm if Al II λ 1670 Å and three Fe II transitions are used, and +1.1 ± 2.6_stat ppm in a slightly different analysis with only Fe II transitions used. This is one of the tightest bounds on α-variation from an individual absorber and reveals no evidence for variation in α at the 3-ppm precision level (1σ confidence). The expectation at this sky position of the recently-reported dipolar variation of α is (3.2-5.4)±1.7 ppm depending on dipole model used and this constraint of Δα/α at face value is not supporting this expectation but not inconsistent with it at the 3σ level. For the proton-to-electron mass ratio the analysis of the H_2 absorption lines of the z_abs ≈ 2.4018 damped Lyα system

  9. Cloning of HSP90, expression and localization of HSP70/90 in different tissues including lactating/non-lactating yak (Bos grunniens) breast tissue.

    PubMed

    Liu, Penggang; Yu, Sijiu; Cui, Yan; He, Junfeng; Yu, Chuan; Wen, Zexing; Pan, Yangyang; Yang, Kun; Song, Liangli; Yang, Xue

    2017-01-01

    The aim of this study is to investigate the expression and localization of HSP70/90 in different tissues and explore the regulation effects of HSP70/90 at lactation period of female yaks. HSP90 mRNA was cloned from the heart samples of female yaks, Quantitative real-time (qRT-PCR), Western blotting (WB), immunohistochemistry and immunofluorescence assays were utilized to analyze the expressions of HSP70/90 mRNA and protein in different tissues. Sequence analysis showed that HSP90 is a conserved molecular chaperone of female yaks. The qRT-PCR, WB results showed that the expressions of HSP70/90 mRNA and protein were significantly different in different tissues, and 3-fold higher expression during the lactation period than the non-lactation period of breast tissue (P < 0.01). Immunohistochemistry and immunofluorescence assays results showed that HSP70/90 were located in the cardiac muscle cells, cerebellar medulla, theca cells lining at the reproductive system, and the mammary epithelia of the breasts. In addition, the expression level of HSP70 was higher than those of HSP90 in all examined tissues. Therefore, our results strongly suggest that the expression and localization of HSP70/90 could provide significant evidence to further research in tissue specific expression, and lactation function of female yaks.

  10. The Noncompetitive Effect of Gambogic Acid Displaces Fluorescence-Labeled ATP but Requires ATP for Binding to Hsp90/HtpG.

    PubMed

    Yue, Qing; Stahl, Frank; Plettenburg, Oliver; Kirschning, Andreas; Warnecke, Athanasia; Zeilinger, Carsten

    2018-05-08

    The heat shock protein 90 (Hsp90) family plays a critical role in maintaining the homeostasis of the intracellular environment for human and prokaryotic cells. Hsp90 orthologues were identified as important target proteins for cancer and plant disease therapies. It was shown that gambogic acid (GBA) has the potential to inhibit human Hsp90. However, it is unknown whether it is also able to act on the bacterial high-temperature protein (HtpG) analogue. In this work, we screened GBA and nine other novel potential Hsp90 inhibitors using a miniaturized high-throughput protein microarray-based assay and found that GBA shows an inhibitory effect on different Hsp90s after dissimilarity analysis of the protein sequence alignment. The dissociation constant of GBA and HtpG Xanthomonas (XcHtpG) computed from microscale thermophoresis is 682.2 ± 408 μM in the presence of ATP, which is indispensable for the binding of GBA to XcHtpG. Our results demonstrate that GBA is a promising Hsp90/HtpG inhibitor. The work further demonstrates that our assay concept has great potential for finding new potent Hsp/HtpG inhibitors.

  11. Struvite recovery from swine waste biogas digester effluent through a stainless steel device under constant pH conditions.

    PubMed

    Perera, P W Anton; Wu, Wei-Xiang; Chen, Ying-Xu; Han, Zhi-Ying

    2009-06-01

    To investigate the struvite precipitation under constant and non-constant pH conditions and to test a stainless steel device under different operating regimes to maximize the recovery of struvite. The molar ratio of NH4+: Mg2+: PO4(3-) was adjusted to 1: 1.2: 1.2 and pH was elevated to 9.0. The absorbance measurement was used to trace the process of struvite crystallization. Wastewater and precipitate analysis was done by standard analytical methods. The pH constant experiment reported a significantly higher struvite precipitation (24.6 +/- 0.86 g) than the non-constant pH experiment (19.8 +/- 1.86 g). The SAR ranged from 5.6 to 8.2 g m(-2) h(-1) to 3.6-4.8 g m(-2) h(-1) in pH constant and non-constant experiments, respectively. The highest struvite deposit on the device was found in regime 3 followed by in regimes 2 and 4. The highest PO4(3-) (97.2%) and NH4+ (71%) removal was reported in the R1 regime. None of the influent Cu2+ or Zn2+ was precipitated on the device. A higher struvite yield is evident in pH constant experiments. Moreover, the stainless steel device facilitates the isolation of heavy metal free pure (around 96%) struvite from swine waste biogas digester effluent contaminated with cu2+ and Zn2+ and the highest yield is attainable with the device operating at 50 rpm with agitation by a magnetic stirrer.

  12. 12 CFR 652.90 - How to report your risk-based capital determination.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false How to report your risk-based capital determination. 652.90 Section 652.90 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM FEDERAL AGRICULTURAL MORTGAGE CORPORATION FUNDING AND FISCAL AFFAIRS Risk-Based Capital Requirements § 652.90 How to...

  13. Rate constants for proteins binding to substrates with multiple binding sites using a generalized forward flux sampling expression

    NASA Astrophysics Data System (ADS)

    Vijaykumar, Adithya; ten Wolde, Pieter Rein; Bolhuis, Peter G.

    2018-03-01

    To predict the response of a biochemical system, knowledge of the intrinsic and effective rate constants of proteins is crucial. The experimentally accessible effective rate constant for association can be decomposed in a diffusion-limited rate at which proteins come into contact and an intrinsic association rate at which the proteins in contact truly bind. Reversely, when dissociating, bound proteins first separate into a contact pair with an intrinsic dissociation rate, before moving away by diffusion. While microscopic expressions exist that enable the calculation of the intrinsic and effective rate constants by conducting a single rare event simulation of the protein dissociation reaction, these expressions are only valid when the substrate has just one binding site. If the substrate has multiple binding sites, a bound enzyme can, besides dissociating into the bulk, also hop to another binding site. Calculating transition rate constants between multiple states with forward flux sampling requires a generalized rate expression. We present this expression here and use it to derive explicit expressions for all intrinsic and effective rate constants involving binding to multiple states, including rebinding. We illustrate our approach by computing the intrinsic and effective association, dissociation, and hopping rate constants for a system in which a patchy particle model enzyme binds to a substrate with two binding sites. We find that these rate constants increase as a function of the rotational diffusion constant of the particles. The hopping rate constant decreases as a function of the distance between the binding sites. Finally, we find that blocking one of the binding sites enhances both association and dissociation rate constants. Our approach and results are important for understanding and modeling association reactions in enzyme-substrate systems and other patchy particle systems and open the way for large multiscale simulations of such systems.

  14. Free energy perturbation method for measuring elastic constants of liquid crystals

    NASA Astrophysics Data System (ADS)

    Joshi, Abhijeet

    There is considerable interest in designing liquid crystals capable of yielding specific morphological responses in confined environments, including capillaries and droplets. The morphology of a liquid crystal is largely dictated by the elastic constants, which are difficult to measure and are only available for a handful of substances. In this work, a first-principles based method is proposed to calculate the Frank elastic constants of nematic liquid crystals directly from atomistic models. These include the standard splay, twist and bend deformations, and the often-ignored but important saddle-splay constant. The proposed method is validated using a well-studied Gay-Berne(3,5,2,1) model; we examine the effects of temperature and system size on the elastic constants in the nematic and smectic phases. We find that our measurements of splay, twist, and bend elastic constants are consistent with previous estimates for the nematic phase. We further outline the implementation of our approach for the saddle-splay elastic constant, and find it to have a value at the limits of the Ericksen inequalities. We then proceed to report results for the elastic constants commonly known liquid crystals namely 4-pentyl-4'-cynobiphenyl (5CB) using atomistic model, and show that the values predicted by our approach are consistent with a subset of the available but limited experimental literature.

  15. Reducing mortality in HIV-infected infants and achieving the 90-90-90 target through innovative diagnosis approaches.

    PubMed

    Essajee, Shaffiq; Vojnov, Lara; Penazzato, Martina; Jani, Ilesh; Siberry, George K; Fiscus, Susan A; Markby, Jessica

    2015-01-01

    Despite significant gains in access to early infant diagnosis (EID) over the past decade, most HIV-exposed infants still do not get tested for HIV in the first two months of life. For those who are tested, the long turnaround time between when the sample is drawn and when the results are returned leads to a high rate of loss to follow-up, which in turn means that few infected infants start antiretroviral treatment. Consequently, there continues to be high mortality from perinatally acquired HIV, and the ambitious goals of 90% of infected children identified, 90% of identified children treated and 90% of treated children with sustained virologic suppression by 2020 seem far beyond our reach. The objective of this commentary is to review recent advances in the field of HIV diagnosis in infants and describe how these advances may overcome long-standing barriers to access to testing and treatment. Several innovative approaches to EID have recently been described. These include point-of-care testing, use of SMS printers to connect the central laboratory and the health facility through a mobile phone network, expanding paediatric testing to other entry points where children access the health system and testing HIV-exposed infants at birth as a rapid way to identify in utero infection. Each of these interventions is discussed here, together with the opportunities and challenges associated with scale-up. Point-of-care testing has the potential to provide immediate results but is less cost-effective in settings where test volumes are low. Virological testing at birth has been piloted in some countries to identify those infants who need urgent treatment, but a negative test at birth does not obviate the need for additional testing at six weeks. Routine testing of infants in child health settings is a useful strategy to identify exposed and infected children whose mothers were not enrolled in programmes for the prevention of mother-to-child transmission. Facility-based SMS

  16. Nitrogen and phosphorus runoff losses from variable and constant intensity rainfall simulations on loamy sand under conventional and strip tillage systems.

    PubMed

    Franklin, D; Truman, C; Potter, T; Bosch, D; Strickland, T; Bednarz, C

    2007-01-01

    Further studies on the quality of runoff from tillage and cropping systems in the southeastern USA are needed to refine current risk assessment tools for nutrient contamination. Our objective was to quantify and compare effects of constant (Ic) and variable (Iv) rainfall intensity patterns on inorganic nitrogen (N) and phosphorus (P) losses from a Tifton loamy sand (Plinthic Kandiudult) cropped to cotton (Gossypium hirsutum L.) and managed under conventional (CT) or strip-till (ST) systems. We simulated rainfall at a constant intensity and a variable intensity pattern (57 mm h(-1)) and collected runoff continuously at 5-min intervals for 70 min. For cumulative runoff at 50 min, the Iv pattern lost significantly greater amounts (p < 0.05) of total Kjeldahl N (TKN) and P (TKP) (849 g N ha(-1) and 266 g P ha(-1) for Iv; 623 g N ha(-1) and 192 g P ha(-1) for Ic) than did the Ic pattern. However, at 70 min, no significant differences in total losses were evident for TKN or TKP from either rainfall intensity pattern. In contrast, total cumulative losses of dissolved reactive P (DRP) and NO3-N were greatest for ST-Ic, followed by ST-Iv, CT-Ic, and CT-Iv in diminishing order (69 g DRP ha(-1) and 361 g NO3-N ha(-1); 37 g DRP ha(-1) and 133 g NO3-N ha(-1); 3 g DRP ha(-1) and 58 g NO3-N ha(-1); 1 g DRP ha(-1) and 49 g NO3-N ha(-1)). Results indicate that constant-rate rainfall simulations may overestimate the amount of dissolved nutrients lost to the environment in overland flow from cropping systems in loamy sand soils. We also found that CT treatments lost significantly greater amounts of TKN and TKP than ST treatments and in contrast, ST treatments lost significantly greater amounts of DRP and NO3-N than CT treatments. These results indicate that ST systems may be losing more soluble fractions than CT systems, but only a fraction the total N (33%) and total P (11%) lost through overland flow from CT systems.

  17. The observational constraint on constant-roll inflation

    NASA Astrophysics Data System (ADS)

    Gao, Qing

    2018-07-01

    We discuss the constant-roll inflation with constant ɛ2 and constant \\bar η . By using the method of Bessel function approximation, the analytical expressions for the scalar and tensor power spectra, the scalar and tensor spectral tilts, and the tensor to scalar ratio are derived up to the first order of ɛ1. The model with constant ɛ2 is ruled out by the observations at the 3σ confidence level, and the model with constant \\bar η is consistent with the observations at the 1σ confidence level. The potential for the model with constant \\bar η is also obtained from the Hamilton-Jacobi equation. Although the observations constrain the constant-roll inflation to be the slow-roll inflation, the n s- r results from the constant-roll inflation are not the same as those from the slow-roll inflation even when \\bar η 0.01.

  18. Low noise constant current source for bias dependent noise measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Talukdar, D.; Bose, Suvendu; Bardhan, K. K.

    2011-01-15

    A low noise constant current source used for measuring the 1/f noise in disordered systems in ohmic as well as nonohmic regime is described. The source can supply low noise constant current starting from as low as 1 {mu}A to a few tens of milliampere with a high voltage compliance limit of around 20 V. The constant current source has several stages, which can work in a standalone manner or together to supply the desired value of load current. The noise contributed by the current source is very low in the entire current range. The fabrication of a low noisemore » voltage preamplifier modified for bias dependent noise measurements and based on the existing design available in the MAT04 data sheet is also described.« less

  19. Elastic constants of calcite

    USGS Publications Warehouse

    Peselnick, L.; Robie, R.A.

    1962-01-01

    The recent measurements of the elastic constants of calcite by Reddy and Subrahmanyam (1960) disagree with the values obtained independently by Voigt (1910) and Bhimasenachar (1945). The present authors, using an ultrasonic pulse technique at 3 Mc and 25??C, determined the elastic constants of calcite using the exact equations governing the wave velocities in the single crystal. The results are C11=13.7, C33=8.11, C44=3.50, C12=4.82, C13=5.68, and C14=-2.00, in units of 1011 dyncm2. Independent checks of several of the elastic constants were made employing other directions and polarizations of the wave velocities. With the exception of C13, these values substantially agree with the data of Voigt and Bhimasenachar. ?? 1962 The American Institute of Physics.

  20. Evaluation of the solubility constants of the hydrated solid phases in the H2O-Al2O3-SO3 ternary system

    NASA Astrophysics Data System (ADS)

    Teyssier, A.; Lagneau, V.; Schmitt, J. M.; Counioux, J. J.; Goutaudier, C.

    2017-04-01

    During the acid processing of aluminosilicate ores, the precipitation of a solid phase principally consisting of hydrated aluminium hydroxysulfates may be observed. The experimental study of the H2O-Al2O3-SO3 ternary system at 25 ∘C and 101 kPa enabled to describe the solid-liquid equilibra and to identify the nature, the composition and the solubility of the solid phases which may form during the acid leaching. To predict the appearance of these aluminium hydroxysulfates in more complex systems, their solubility constants were calculated by modelling the experimental solubility results, using a geochemical reaction modelling software, CHESS. A model for non-ideality correction, based on the B-dot equation, was used as it was suitable for the considered ion concentration range. The solubility constants of three out of four solid phases were calculated: 104.08 for jurbanite (Al(SO4)(OH).5H2O), 1028.09 for the solid T (Al8(SO4)5(OH)14.34H2O) and 1027.28 for the solid V (Al10(SO4)3(OH)24.20H2O). However the activity correction model was not suitable to determine the solubility constant of alunogen (Al2(SO4)3.15.8H2O), as the ion concentrations of the mixtures were too high and beyond the allowable limits of the model. Another ionic activity correction model, based on the Pitzer equation for example, must be applied to calculate the solubility constant of alunogen.

  1. The 90-kDa Heat Shock Protein Hsp90 Protects Tubulin against Thermal Denaturation*

    PubMed Central

    Weis, Felix; Moullintraffort, Laura; Heichette, Claire; Chrétien, Denis; Garnier, Cyrille

    2010-01-01

    Hsp90 and tubulin are among the most abundant proteins in the cytosol of eukaryotic cells. Although Hsp90 plays key roles in maintaining its client proteins in their active state, tubulin is essential for fundamental processes such as cell morphogenesis and division. Several studies have suggested a possible connection between Hsp90 and the microtubule cytoskeleton. Because tubulin is a labile protein in its soluble form, we investigated whether Hsp90 protects it against thermal denaturation. Both proteins were purified from porcine brain, and their interaction was characterized in vitro by using spectrophotometry, sedimentation assays, video-enhanced differential interference contrast light microscopy, and native polyacrylamide gel electrophoresis. Our results show that Hsp90 protects tubulin against thermal denaturation and keeps it in a state compatible with microtubule polymerization. We demonstrate that Hsp90 cannot resolve tubulin aggregates but that it likely binds early unfolding intermediates, preventing their aggregation. Protection was maximal at a stoichiometry of two molecules of Hsp90 for one of tubulin. This protection does not require ATP binding and hydrolysis by Hsp90, but it is counteracted by geldanamycin, a specific inhibitor of Hsp90. PMID:20110359

  2. DETERMINATION OF HENRY'S LAW CONSTANTS OF SELECTED PRIORITY POLLUTANTS

    EPA Science Inventory

    The Henry's law constants (H) for 41 selected priority pollutants were determined to characterize these pollutants and provide information on their fate as they pass through wastewater treatment systems. All experimental values presented for H are averages of two or more replicat...

  3. Connecting Fundamental Constants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Di Mario, D.

    2008-05-29

    A model for a black hole electron is built from three basic constants only: h, c and G. The result is a description of the electron with its mass and charge. The nature of this black hole seems to fit the properties of the Planck particle and new relationships among basic constants are possible. The time dilation factor in a black hole associated with a variable gravitational field would appear to us as a charge; on the other hand the Planck time is acting as a time gap drastically limiting what we are able to measure and its dimension willmore » appear in some quantities. This is why the Planck time is numerically very close to the gravitational/electric force ratio in an electron: its difference, disregarding a {pi}{radical}(2) factor, is only 0.2%. This is not a coincidence, it is always the same particle and the small difference is between a rotating and a non-rotating particle. The determination of its rotational speed yields accurate numbers for many quantities, including the fine structure constant and the electron magnetic moment.« less

  4. Y90 Radioembolization in chemo-refractory metastastic, liver dominant colorectal cancer patients: outcome assessment applying a predictive scoring system.

    PubMed

    Damm, Robert; Seidensticker, Ricarda; Ulrich, Gerhard; Breier, Leonie; Steffen, Ingo G; Seidensticker, Max; Garlipp, Benjamin; Mohnike, Konrad; Pech, Maciej; Amthauer, Holger; Ricke, Jens

    2016-07-20

    In treatment-refractory liver dominant metastatic colorectal cancer, the role of liver directed therapies still is unclear. We sought to determine a prognostic score for Y90 radioembolization in these patients. We analyzed 106 patients with refractory liver dominant mCRC who had undergone a total of 178 Y90 radioembolizations with resin microspheres was collected. Potential factors influencing survival were analyzed using a Cox regression. The Log rank test served to establish prognostic factors and to form a clinical score for outcome prediction after Y90 radioembolization. Median survival of all patients was 6.7 months. Neither age nor prior surgical or systemic therapy nor metastatic spread had an effect on survival. In contrast, hepatic tumor load, Karnofsky index as well as CEA and CA19-9 serums level had a significant influence (p < 0.001, p = 0.037, p = 0.023 and p < 0.001, respectively). These three factors formed a score with 1 point each for tumor load >20 %, CEA >130 ng/ml or CA19-9 > 200U/ml and Karnofsky index <80 %. Patients with a score of 0 and 1 displayed a median OS of 10.4 months. Patients with a score of 2 and 3 demonstrated a median OS of 5.1 months only (p < 0.001). Overaggressive patient selection for Y90 radioembolization of liver dominant chemorefractory mCRC is of questionable benefit. A scoring system comprising hepatic tumor load, CEA and CA19-9 serum levels and Karnofsky index (TuCK-score) may support an improved patient selection. In our cohort of liver only versus liver dominant disease, extrahepatic lung or lymphatic metastases did not significantly alter the prognosis.

  5. Effect of a constant-level lighting control system on small offices with windows. Final technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edgar, L.

    To reduce energy consumption stemming from lighting, some of the fixtures in Army office buildings have been delamped and building energy managers have instituted the policy of turning lights off when not in use. Even with these measures, lighting is still one of the largest consumers of electricity. The current problem is to find ways to reduce the energy consumption of lighting systems when they are in use. The objectives of this research was to provide information on the performance and energy savings potential of constant level lighting (CLL) controls. Based on a review of product information, researchers selected themore » Conservolite Plus 20 for testing and installed it in 10 office spaces. After 4 months of operation, a survey of the office occupants revealed that they were satisfied with the CLL system. Although electrical cost savings were realized, the payback period varied greatly, depending on the cost of replacing old or inoperable lamps and ballasts. Before large scale installation of CLL systems, it is recommended that the power factor and harmonic distortion be monitored at a large facility.« less

  6. How fundamental are fundamental constants?

    NASA Astrophysics Data System (ADS)

    Duff, M. J.

    2015-01-01

    I argue that the laws of physics should be independent of one's choice of units or measuring apparatus. This is the case if they are framed in terms of dimensionless numbers such as the fine structure constant, ?. For example, the standard model of particle physics has 19 such dimensionless parameters whose values all observers can agree on, irrespective of what clock, rulers or scales? they use to measure them. Dimensional constants, on the other hand, such as ?, c, G, e and k ?, are merely human constructs whose number and values differ from one choice of units to the next. In this sense, only dimensionless constants are 'fundamental'. Similarly, the possible time variation of dimensionless fundamental 'constants' of nature is operationally well defined and a legitimate subject of physical enquiry. By contrast, the time variation of dimensional constants such as ? or ? on which a good many (in my opinion, confusing) papers have been written, is a unit-dependent phenomenon on which different observers might disagree depending on their apparatus. All these confusions disappear if one asks only unit-independent questions. We provide a selection of opposing opinions in the literature and respond accordingly.

  7. Reactive oxygen species promote heat shock protein 90-mediated HBV capsid assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Yoon Sik, E-mail: yumshak@naver.com; Seo, Hyun Wook, E-mail: suruk@naver.com; Jung, Guhung, E-mail: drjung@snu.ac.kr

    2015-02-13

    Hepatitis B virus (HBV) infection induces reactive oxygen species (ROS) production and has been associated with the development of hepatocellular carcinoma (HCC). ROS are also an important factor in HCC because the accumulated ROS leads to abnormal cell proliferation and chromosome mutation. In oxidative stress, heat shock protein 90 (Hsp90) and glutathione (GSH) function as part of the defense mechanism. Hsp90 prevents cellular component from oxidative stress, and GSH acts as antioxidants scavenging ROS in the cell. However, it is not known whether molecules regulated by oxidative stress are involved in HBV capsid assembly. Based on the previous study thatmore » Hsp90 facilitates HBV capsid assembly, which is an important step for the packing of viral particles, here, we show that ROS enrich Hsp90-driven HBV capsid formation. In cell-free system, HBV capsid assembly was facilitated by ROS with Hsp90, whereas it was decreased without Hsp90. In addition, GSH inhibited the function of Hsp90 to decrease HBV capsid assembly. Consistent with the result of cell-free system, ROS and buthionine sulfoximine (BS), an inhibitor of GSH synthesis, increased HBV capsid formation in HepG2.2.15 cells. Thus, our study uncovers the interplay between ROS and Hsp90 during HBV capsid assembly. - Highlights: • We examined H{sub 2}O{sub 2} and GSH modulate HBV capsid assembly. • H{sub 2}O{sub 2} facilitates HBV capsid assembly in the presence of Hsp90. • GSH inhibits function of Hsp90 in facilitating HBV capsid assembly. • H{sub 2}O{sub 2} and GSH induce conformation change of Hsp90.« less

  8. 47 CFR 90.733 - Permissible operations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... benchmark for the construction of its land mobile system base stations as prescribed in § 90.725(a); and (2... first meet the requirement to construct its land mobile base station and place it in operation, or... chapter. (f) A Phase I non-nationwide licensee operating a paging base station, or a fixed station...

  9. An infrared band system of the ZrCl molecule

    NASA Astrophysics Data System (ADS)

    Phillips, J. G.; Davis, S. P.; Galehouse, D. C.

    1980-07-01

    A series of infrared bands in the 0.97-1.15 micron region which is attributed to ZrCl is analyzed in light of the possibility that the bands may be observable in stellar spectra. Spectra of ZrO and ZrCl were produced by microwave discharge through a mixture of He, O and ZrCl4 and observed by Fourier transform spectrometer, resulting in the observation of 10 bands of the ZrCl system. Rotational quantum number assignments to the lines of the P and R branches observed are obtained and used to derive effective rotational constants for each substate, as well as zero-rotation origins of each subband. Shifts in wave numbers of rotational lines of the isotopes (Zr-92)(Cl-35)(Zr-94)(Cl-35) and (Zr-90)(Cl-37) relative to the more abundant (Zr-90)(Cl-35) are also observed. The observed molecular constants are shown to be in good agreement with those calculated in previous theoretical estimates.

  10. Nuclear shielding constants by density functional theory with gauge including atomic orbitals

    NASA Astrophysics Data System (ADS)

    Helgaker, Trygve; Wilson, Philip J.; Amos, Roger D.; Handy, Nicholas C.

    2000-08-01

    Recently, we introduced a new density-functional theory (DFT) approach for the calculation of NMR shielding constants. First, a hybrid DFT calculation (using 5% exact exchange) is performed on the molecule to determine Kohn-Sham orbitals and their energies; second, the constants are determined as in nonhybrid DFT theory, that is, the paramagnetic contribution to the constants is calculated from a noniterative, uncoupled sum-over-states expression. The initial results suggested that this semiempirical DFT approach gives shielding constants in good agreement with the best ab initio and experimental data; in this paper, we further validate this procedure, using London orbitals in the theory, having implemented DFT into the ab initio code DALTON. Calculations on a number of small and medium-sized molecules confirm that our approach produces shieldings in excellent agreement with experiment and the best ab initio results available, demonstrating its potential for the study of shielding constants of large systems.

  11. Binding Rate Constants Reveal Distinct Features of Disordered Protein Domains.

    PubMed

    Dogan, Jakob; Jonasson, Josefin; Andersson, Eva; Jemth, Per

    2015-08-04

    Intrinsically disordered proteins (IDPs) are abundant in the proteome and involved in key cellular functions. However, experimental data about the binding kinetics of IDPs as a function of different environmental conditions are scarce. We have performed an extensive characterization of the ionic strength dependence of the interaction between the molten globular nuclear co-activator binding domain (NCBD) of CREB binding protein and five different protein ligands, including the intrinsically disordered activation domain of p160 transcriptional co-activators (SRC1, TIF2, ACTR), the p53 transactivation domain, and the folded pointed domain (PNT) of transcription factor ETS-2. Direct comparisons of the binding rate constants under identical conditions show that the association rate constant, kon, for interactions between NCBD and disordered protein domains is high at low salt concentrations (90-350 × 10(6) M(-1) s(-1) at 4 °C) but is reduced significantly (10-30-fold) with an increasing ionic strength and reaches a plateau around physiological ionic strength. In contrast, the kon for the interaction between NCBD and the folded PNT domain is only 7 × 10(6) M(-1) s(-1) (4 °C and low salt) and displays weak ionic strength dependence, which could reflect a distinctly different association that relies less on electrostatic interactions. Furthermore, the basal rate constant (in the absence of electrostatic interactions) is high for the NCBD interactions, exceeding those typically observed for folded proteins. One likely interpretation is that disordered proteins have a large number of possible collisions leading to a productive on-pathway encounter complex, while folded proteins are more restricted in terms of orientation. Our results highlight the importance of electrostatic interactions in binding involving IDPs and emphasize the significance of including ionic strength as a factor in studies that compare the binding properties of IDPs to those of ordered proteins.

  12. Some Dynamical Effects of the Cosmological Constant

    NASA Astrophysics Data System (ADS)

    Axenides, M.; Floratos, E. G.; Perivolaropoulos, L.

    Newton's law gets modified in the presence of a cosmological constant by a small repulsive term (antigravity) that is proportional to the distance. Assuming a value of the cosmological constant consistent with the recent SnIa data (Λ~=10-52 m-2), we investigate the significance of this term on various astrophysical scales. We find that on galactic scales or smaller (less than a few tens of kpc), the dynamical effects of the vacuum energy are negligible by several orders of magnitude. On scales of 1 Mpc or larger however we find that the vacuum energy can significantly affect the dynamics. For example we show that the velocity data in the local group of galaxies correspond to galactic masses increased by 35% in the presence of vacuum energy. The effect is even more important on larger low density systems like clusters of galaxies or superclusters.

  13. Effective optical constants of anisotropic materials

    NASA Technical Reports Server (NTRS)

    Aronson, J. R.; Emslie, A. G.

    1980-01-01

    The applicability of a technique for determining the optical constants of soil or aerosol components on the basis of measurements of the reflectance or transmittance of inhomogeneous samples of component material is investigated. Optical constants for a sample of very pure quartzite were obtained by a specular reflection technique and line parameters were calculated by classical dispersion theory. Predictions of the reflectance of powdered quartz were then derived from optical constants measured for the anisotropic quartz and for pure quartz crystals, and compared with experimental measurements. The calculated spectra are found to resemble each other moderately well in shape, however the reflectance level calculated from the psuedo-optical constants (quartzite) is consistently below that calculated from quartz values. The spectrum calculated from the quartz optical constants is also shown to represent the experimental nonrestrahlen features more accurately. It is thus concluded that although optical constants derived from inhomogeneous materials may represent the spectral features of a powdered sample qualitatively a quantitative fit to observed data is not likely.

  14. Use of Chelex-100 for selectively removing Y-90 from its parent Sr-90

    DOEpatents

    Huntley, Mark W.

    1996-01-01

    A method for selectively removing yttrium-90 from its parent strontium-90 contained in an environmental sample includes loading the sample onto a column containing a chelating ion-exchange resin capable of retaining yttrium-90; washing the column with a solution capable of removing strontium, calcium, and other contaminants from the yttrium-90 fraction retained on the column; removing excess acetate salts from the column; eluting yttrium-90 solution from the column and adjusting the pH of this solution to about 2.7; filtering the yttrium-90 solution and weighing this solution for gravimetric yield; and, counting the yttrium-90 containing solution with a radiological counter for a time sufficient to achieve the statistical accuracy desired. It is preferred that the chelating ion-exchange resin is a bidente ligand having the chemical name iminodiacetic acid mounted on a divinyl benzene substrate, converted from sodium form to ammonia form.

  15. Use of Chelex-100 for selectively removing Y-90 from its parent Sr-90

    DOEpatents

    Huntley, M.W.

    1996-02-27

    A method for selectively removing yttrium-90 from its parent strontium-90 contained in an environmental sample includes loading the sample onto a column containing a chelating ion-exchange resin capable of retaining yttrium-90; washing the column with a solution capable of removing strontium, calcium, and other contaminants from the yttrium-90 fraction retained on the column; removing excess acetate salts from the column; eluting yttrium-90 solution from the column and adjusting the pH of this solution to about 2.7; filtering the yttrium-90 solution and weighing this solution for gravimetric yield; and, counting the yttrium-90 containing solution with a radiological counter for a time sufficient to achieve the statistical accuracy desired. It is preferred that the chelating ion-exchange resin is a ligand having the chemical name iminodiacetic acid mounted on a divinyl benzene substrate, converted from sodium form to ammonia form.

  16. Yttrium-90 -- current status, expected availability and applications of a high beta energy emitter.

    PubMed

    Montaña, R Leyva; González, I Hernández; Ramirez, A Alberti; Garaboldi, L; Chinol, M

    2012-07-01

    Yttrium-90 ((90)Y, T(1/2) 64.14 h) is a key example of a high beta energy-emitting radionuclide which is available from the strontium-90 ((90)Sr)/(90)Y radionuclide generator system. Clinical uses of (90)Y-labeled radiopharmaceutical agents have been pursued for many years and many applications have proven to be clinical effective. These most notably include the application of 90Y-labeled antibodies for a variety of applications such as for effective treatment of non-Hodgkin's lymphoma. One of the major advantages for use of (90)Y is ready availability from the very long-lived (90)Sr parent (T(1/2) 28.78 y). Because of the importance of maintaining generator performance and minimizing parent breakthrough, this paper describes development, use and quality control of both high capacity cation adsorption-type and electrochemical generator systems. In addition, the preparation and targeting to tumors in mice of DOTA-conjugated Nimotuzamab (h-R3) antibody which recognizes the external domain of the EPFR antibody radiolabeled with (90)Y obtained from the electrochemical generator is also described. As a key example for clinical applications of (90)Y, the use of (90)Y-labeled biotin for intra-operative pre-targeting for radionuclide therapy (IART®) of breast cancer is also described.

  17. Strengthening the HIV Care Continuum in the Dominican Republic: Application of a Triadic Implementation Framework to Meet the UNAIDS 90-90-90 Treatment Goal.

    PubMed

    Bowman, Alex S; Mehta, Mili; Lerebours Nadal, Leonel; Halpern, Mina; Nicholas, Stephen W; Amesty, Silvia

    2017-10-01

    Innovative empirical frameworks to evaluate progress in efforts addressing HIV treatment and prevention barriers in resource-limited areas are sorely needed to achieve the UNAIDS 90-90-90 goal (90% diagnosed, 90% on treatment, and 90% virally suppressed). A triadic implementation framework (TIF) is a comprehensive conceptual tool for (1) monitoring attrition, (2) evaluating operational programs, and (3) measuring the impact of specific implementation goals within the care continuum. TIF will assess the effects of enhanced programs on adherence and virologic suppression within the HIV care continuum at a regional clinic in the Dominican Republic (Clínica de Familia La Romana [CFLR]) and its program serving high-risk, migratory batey (sugarcane cultivation) communities. A retrospective cohort study completed during 2015 collected deidentified data from a CFLR chart review of adult HIV patients diagnosed in 2013. The results were quantitatively analyzed and compared to 2011 cohort data. In 2013, 310 patients were diagnosed HIV positive. The results demonstrated 73% enrolling in care, 28% adhering to care, and 16% achieving viral load suppression. Engagement increased across all steps of the care continuum compared to a 2011 cohort, culminating in a significant increase in undetectable viral load from 4% to 16% (p < 0.001). The batey program showed significant increases in patient enrollment compared to the 2011 cohort (p < 0.001). Meeting the UNAIDS 90-90-90 goal requires enhanced services in high-burden, resource-limited regions. CFLR employs TIF to assess progress and programmatic areas in need of strengthening. Data suggest enhanced CFLR services improve outcomes. Given improvements, maintenance and expansion of similar programs are warranted to achieve the 90-90-90 goal.

  18. Apparatus for adjusting and maintaining the humidity of gas at a constant value within a closed system

    DOEpatents

    Abernathy, Bethel R.; Walters, Ronald R.

    1986-01-01

    The humidity of a gas within a closed system is maintained at constant level by providing a saturated salt solution within a lower chamber in communication with an upper chamber conjointly defined by upper and lower container sections in sealing contact with each other to establish a closed container. A partition wall separates the salt solution from the test region in the upper chamber. A tube extending through the partition plate allows humidified gas to pass from the lower to the upper chamber. A glass wool plug or membranous material within the tube prevents migration of salt into the test region.

  19. Apparatus for adjusting and maintaining the humidity of gas at a constant value within a closed system

    DOEpatents

    Abernathy, B.R.; Walters, R.R.

    1985-08-05

    The humidity of a gas within a closed system is maintained at constant level by providing a saturated salt solution within a lower chamber in communication with an upper chamber conjointly defined by upper and lower container sections in sealing contact with each other to establish a closed container. A partition wall separates the salt solution from the test region in the upper chamber. A tube extending through the partition plate allows humidified gas to pass from the lower to the upper chamber. A glass wool plug or membranous material within the tube prevents migration of salt into the test region.

  20. Constant Communities in Complex Networks

    NASA Astrophysics Data System (ADS)

    Chakraborty, Tanmoy; Srinivasan, Sriram; Ganguly, Niloy; Bhowmick, Sanjukta; Mukherjee, Animesh

    2013-05-01

    Identifying community structure is a fundamental problem in network analysis. Most community detection algorithms are based on optimizing a combinatorial parameter, for example modularity. This optimization is generally NP-hard, thus merely changing the vertex order can alter their assignments to the community. However, there has been less study on how vertex ordering influences the results of the community detection algorithms. Here we identify and study the properties of invariant groups of vertices (constant communities) whose assignment to communities are, quite remarkably, not affected by vertex ordering. The percentage of constant communities can vary across different applications and based on empirical results we propose metrics to evaluate these communities. Using constant communities as a pre-processing step, one can significantly reduce the variation of the results. Finally, we present a case study on phoneme network and illustrate that constant communities, quite strikingly, form the core functional units of the larger communities.

  1. Investigation into constant envelope orthogonal frequency division multiplexing for polarization-division multiplexing coherent optical communication

    NASA Astrophysics Data System (ADS)

    Li, Yupeng; Ding, Ding

    2017-09-01

    Benefiting from the high spectral efficiency and low peak-to-average power ratio, constant envelope orthogonal frequency division multiplexing (OFDM) is a promising technique in coherent optical communication. Polarization-division multiplexing (PDM) has been employed as an effective way to double the transmission capacity in the commercial 100 Gb/s PDM-QPSK system. We investigated constant envelope OFDM together with PDM. Simulation results show that the acceptable maximum launch power into the fiber improves 10 and 6 dB for 80- and 320-km transmission, respectively (compared with the conventional PDM OFDM system). The maximum reachable distance of the constant envelope OFDM system is able to reach 800 km, and even 1200 km is reachable if an ideal erbium doped fiber amplifier is employed.

  2. Strontium-90 in hair.

    PubMed

    HOPKINS, B J; TUTTLE, L W; PORIES, W J; STRAIN, W H

    1963-03-15

    The hair of rats injected with strontium-90 retains a significant amount of the radionuclide. Although the strontium-90 content of hair is variable in these rats and appears to be subject to a variety of influences, determination of the radionuclide content of hair may offer a nondestructive method of estimating strontium-90 in bone.

  3. Constant-Differential-Pressure Two-Fluid Accumulator

    NASA Technical Reports Server (NTRS)

    Piecuch, Benjamin; Dalton, Luke T.

    2010-01-01

    A two-fluid accumulator has been designed, built, and demonstrated to provide an acceptably close approximation to constant differential static pressure between two fluids over the full ranges of (1) accumulator stroke, (2) rates of flow of the fluids, and (3) common static pressure applied to the fluids. Prior differential- pressure two-fluid accumulators are generally not capable of maintaining acceptably close approximations to constant differential pressures. The inadequacies of a typical prior differential-pressure two-fluid accumulator can be summarized as follows: The static differential pressure is governed by the intrinsic spring rate (essentially, the stiffness) of an accumulator tank. The spring rate can be tailored through selection of the tank-wall thickness, selection of the number and/or shape of accumulator convolutions, and/or selection of accumulator material(s). Reliance on the intrinsic spring rate of the tank results in three severe limitations: (1) The spring rate and the expulsion efficiency tend to be inversely proportional to each other: that is to say, as the stiffness (and thus the differential pressure) is increased, the range of motion of the accumulator is reduced. (2) As the applied common static pressure increases, the differential pressure tends to decrease. An additional disadvantage, which may or may not be considered limiting, depending on the specific application, is that an increase in stiffness entails an increase in weight. (3) The additional weight required by a low expulsion efficiency accumulator eliminates the advantage given to such gas storage systems. The high expulsion efficiency provided by this two-fluid accumulator allows for a lightweight, tightly packaged system, which can be used in conjunction with a fuel cell-based system.

  4. Hsp90 Promotes Kinase Evolution

    PubMed Central

    Lachowiec, Jennifer; Lemus, Tzitziki; Borenstein, Elhanan; Queitsch, Christine

    2015-01-01

    Heat-shock protein 90 (Hsp90) promotes the maturation and stability of its client proteins, including many kinases. In doing so, Hsp90 may allow its clients to accumulate mutations as previously proposed by the capacitor hypothesis. If true, Hsp90 clients should show increased evolutionary rate compared with nonclients; however, other factors, such as gene expression and protein connectivity, may confound or obscure the chaperone’s putative contribution. Here, we compared the evolutionary rates of many Hsp90 clients and nonclients in the human protein kinase superfamily. We show that Hsp90 client status promotes evolutionary rate independently of, but in a small magnitude similar to that of gene expression and protein connectivity. Hsp90’s effect on kinase evolutionary rate was detected across mammals, specifically relaxing purifying selection. Hsp90 clients also showed increased nucleotide diversity and harbored more damaging variation than nonclient kinases across humans. These results are consistent with the central argument of the capacitor hypothesis that interaction with the chaperone allows its clients to harbor genetic variation. Hsp90 client status is thought to be highly dynamic with as few as one amino acid change rendering a protein dependent on the chaperone. Contrary to this expectation, we found that across protein kinase phylogeny Hsp90 client status tends to be gained, maintained, and shared among closely related kinases. We also infer that the ancestral protein kinase was not an Hsp90 client. Taken together, our results suggest that Hsp90 played an important role in shaping the kinase superfamily. PMID:25246701

  5. 47 CFR 90.535 - Modulation and spectrum usage efficiency requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... through the Universal Licensing System that they are operating these channels at a voice efficiency of at... requirements. Transmitters designed to operate in 769-775 MHz and 799-805 MHz frequency bands must meet the... operate on the low power channels designated in §§ 90.531(b)(3), 90.531(b)(4), are exempt from this...

  6. 47 CFR 90.535 - Modulation and spectrum usage efficiency requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... through the Universal Licensing System that they are operating these channels at a voice efficiency of at... requirements. Transmitters designed to operate in 769-775 MHz and 799-805 MHz frequency bands must meet the... operate on the low power channels designated in §§ 90.531(b)(3), 90.531(b)(4), are exempt from this...

  7. 47 CFR 90.535 - Modulation and spectrum usage efficiency requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... through the Universal Licensing System that they are operating these channels at a voice efficiency of at... requirements. Transmitters designed to operate in 769-775 MHz and 799-805 MHz frequency bands must meet the... operate on the low power channels designated in §§ 90.531(b)(3), 90.531(b)(4), are exempt from this...

  8. 47 CFR 90.535 - Modulation and spectrum usage efficiency requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... through the Universal Licensing System that they are operating these channels at a voice efficiency of at... requirements. Transmitters designed to operate in 769-775 MHz and 799-805 MHz frequency bands must meet the... operate on the low power channels designated in §§ 90.531(b)(3), 90.531(b)(4), are exempt from this...

  9. 47 CFR 90.535 - Modulation and spectrum usage efficiency requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... through the Universal Licensing System that they are operating these channels at a voice efficiency of at... requirements. Transmitters designed to operate in 769-775 MHz and 799-805 MHz frequency bands must meet the... operate on the low power channels designated in §§ 90.531(b)(3), 90.531(b)(4), are exempt from this...

  10. Practical Considerations for Using Constant Force Springs in Space-Based Mechanisms

    NASA Technical Reports Server (NTRS)

    Williams, R. Brett; Fisher, Charles D.; Gallon, John C.

    2013-01-01

    Mechanical springs are a common element in mechanism from all walks of life; cars, watches, appliances, and many others. These springs generally exhibit a linear relationship between force and deflection. In small mechanisms, deflections are small so the variation in spring force between one position and another are generally small and do not influence the design or functionality of the device. However, as the spacecraft industry drives towards larger, deployable satellites, the distances a spring or springs must function over can become considerable so much so that the structural integrity of the device may be impacted. As such, an increasingly common mechanism element is the constant force spring- one that provides a constant force regardless of deflection. These elements are commonly in the conceptual design phase to deal with system-level large deflections, but in the detailed design or integration test phase they can pose significant implementation issues. This article addresses some of the detailed issues in order for these constant force springs to be properly designed into space systems.

  11. Treatment of conjunctival lymphomas by beta-ray brachytherapy using a strontium-90-yttrium-90 applicator.

    PubMed

    Regueiro, C A; Valcárcel, F J; Romero, J; de la Torre, A

    2002-12-01

    We reviewed the outcome of the 10 patients (13 eyes) with localized, biopsy-proven, low-grade lymphoma of the conjunctiva treated at our Department between 1988 and 1997. All patients were treated by beta-ray brachytherapy using a bidirectional 90Sr-90Y ophthalmic applicator (Applicator SIA 2, Amersham plc). Total doses, prescribed at the surface of the applicator, varied between 40 Gy and 80 Gy. With a median follow-up of 78 months (range: 14 to 146 months), seven patients remained with no evidence of relapse (67.5% 10 year disease free survival). Local control was achieved in 10 out of 13 eyes (76.9%). Two of the three local relapses were marginal. One of these three patients also developed a metachronous lymphoma in the contralateral conjunctiva. These three patients underwent a second course of brachytherapy with 90Sr/90Y and remained free of second relapse 109, 68 and 33 months after salvage therapy. No cases of systemic relapse were observed. Late (LENT-SOMA) complications were of grade 2 in five eyes, of grade 3 in one eye and of grade 4 in one eye. Late complications of grade 2 or higher were observed in one out of five patients (20%) treated with doses lower or equal to 50 Gy and in six out of eight patients (75%) treated with doses higher than 50 Gy (P=0.086). Our data indicates that beta-ray brachytherapy was ultimately able to control most conjunctival lymphomas but carried a risk of late complications and marginal relapses that was possibly higher than the rates reported for other radiotherapy techniques.

  12. 30 CFR 90.3 - Part 90 option; notice of eligibility; exercise of option.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Part 90 option; notice of eligibility; exercise... DEVELOPMENT OF PNEUMOCONIOSIS General § 90.3 Part 90 option; notice of eligibility; exercise of option. (a... meter of air. Each of these miners shall be notified in writing of eligibility to exercise the option...

  13. 30 CFR 90.3 - Part 90 option; notice of eligibility; exercise of option.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Part 90 option; notice of eligibility; exercise... DEVELOPMENT OF PNEUMOCONIOSIS General § 90.3 Part 90 option; notice of eligibility; exercise of option. (a... meter of air. Each of these miners shall be notified in writing of eligibility to exercise the option...

  14. 30 CFR 90.3 - Part 90 option; notice of eligibility; exercise of option.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Part 90 option; notice of eligibility; exercise... DEVELOPMENT OF PNEUMOCONIOSIS General § 90.3 Part 90 option; notice of eligibility; exercise of option. (a... meter of air. Each of these miners shall be notified in writing of eligibility to exercise the option...

  15. Patterns of Cs-137 and Sr-90 distribution in conjugated landscape systems

    NASA Astrophysics Data System (ADS)

    Korobova, E.

    2012-04-01

    The main goal of the study was to reveal spatial patterns of 137Cs and 90Sr distribution in soils and plants of conjugated landscapes and to use 137Cs as a tracer for natural migration and accumulation processes in the environment. The studies were based on presumptions that: 1) the environment consisted of interrelated bio- and geochemical fields of hierarchical structure depending on the level and age of factors responsible for spatial distribution of chemical elements; 2)distribution of technogenic radionuclides in natural landscapes depended upon the location and type of the initial source and radionuclide involvement in natural pathways controlled by the state and mobility of the typomorphic elements and water migration. Case studies were undertaken in areas subjected to contamination after the Chernobyl accident and in the estuary zones of the Yenisey and Pechora rivers. First observations in the Chernobyl remote zone in 1987-1989 demonstrated relation between the dose rate, 137Cs, 134Cs, 144Ce, 106Ru, 125Sb in soil cover and the location of the measured plot in landscape toposequence. Later study of 137Cs and 90Sr concentration and speciation confirmed different patterns of their distribution dependent upon the radioisotope, soil features and vegetation cover corresponding to the local landscape and landuse structure. Certain patterns in distribution and migration of 137Cs and 90Sr in soils and local food chain were followed in private farms situated in different landscape position [1]. Detailed study of 137Cs activity in forested site with a pronounced relief 20 and 25 years after the Chernobyl accident showed its stable polycentric structure in soils, mosses and litter which was sensitive to meso- and micro-relief features [2]. Radionuclide contamination of the lower Yenisey and Pechora studied along meridian landscape transects proved both areas be subjected to global 137Cs pollution while the Yenisey floodplain received additional regional contamination

  16. Determination of acidity constants of curcumin in aqueous solution and apparent rate constant of its decomposition

    NASA Astrophysics Data System (ADS)

    Bernabé-Pineda, Margarita; Ramírez-Silva, María. Teresa; Romero-Romo, Mario; González-Vergara, Enrique; Rojas-Hernández, Alberto

    2004-04-01

    The stability of curcumin (H 3Cur) in aqueous media is improved when the systems in which it is present are at high pH values (higher than 11.7), fitting a model describable by a pseudo-zero order with a rate constant k' for the disappearance of the Cur 3- species of 1.39 (10 -9) M min -1. There were three acidity constants measured for the curcumin as follows: p KA3=10.51±0.01 corresponding to the equilibrium HCur 2-=Cur 3-+H +, a p KA2=9.88±0.02 corresponding to the equilibrium H 2Cur -=HCur -2+H +. These p KA values were attributed to the hydrogen of the phenol part of the curcumin, while the p KA1=8.38±0.04 corresponds to the equilibrium H 3Cur=H 2Cur -+H + and is attributed the acetylacetone type group. Formation of quinoid structures play an important role in the tautomeric forms of the curcumin in aqueous media, which makes the experimental values differ from the theoretically calculated ones, depending on the conditions adopted in the study.

  17. Precisely and Accurately Inferring Single-Molecule Rate Constants

    PubMed Central

    Kinz-Thompson, Colin D.; Bailey, Nevette A.; Gonzalez, Ruben L.

    2017-01-01

    The kinetics of biomolecular systems can be quantified by calculating the stochastic rate constants that govern the biomolecular state versus time trajectories (i.e., state trajectories) of individual biomolecules. To do so, the experimental signal versus time trajectories (i.e., signal trajectories) obtained from observing individual biomolecules are often idealized to generate state trajectories by methods such as thresholding or hidden Markov modeling. Here, we discuss approaches for idealizing signal trajectories and calculating stochastic rate constants from the resulting state trajectories. Importantly, we provide an analysis of how the finite length of signal trajectories restrict the precision of these approaches, and demonstrate how Bayesian inference-based versions of these approaches allow rigorous determination of this precision. Similarly, we provide an analysis of how the finite lengths and limited time resolutions of signal trajectories restrict the accuracy of these approaches, and describe methods that, by accounting for the effects of the finite length and limited time resolution of signal trajectories, substantially improve this accuracy. Collectively, therefore, the methods we consider here enable a rigorous assessment of the precision, and a significant enhancement of the accuracy, with which stochastic rate constants can be calculated from single-molecule signal trajectories. PMID:27793280

  18. Universe of constant

    NASA Astrophysics Data System (ADS)

    Yongquan, Han

    2016-10-01

    The ideal gas state equation is not applicable to ordinary gas, it should be applied to the Electromagnetic ``gas'' that is applied to the radiation, the radiation should be the ultimate state of matter changes or initial state, the universe is filled with radiation. That is, the ideal gas equation of state is suitable for the Singular point and the universe. Maybe someone consider that, there is no vessel can accommodate radiation, it is because the Ordinary container is too small to accommodate, if the radius of your container is the distance that Light through an hour, would you still think it can't accommodates radiation? Modern scientific determinate that the radius of the universe now is about 1027 m, assuming that the universe is a sphere whose volume is approximately: V = 4.19 × 1081 cubic meters, the temperature radiation of the universe (cosmic microwave background radiation temperature of the universe, should be the closest the average temperature of the universe) T = 3.15k, radiation pressure P = 5 × 10-6 N / m 2, according to the law of ideal gas state equation, PV / T = constant = 6 × 1075, the value of this constant is the universe, The singular point should also equal to the constant Author: hanyongquan

  19. 41 CFR 102-85.90 - What is a tenant improvement allowance?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What is a tenant improvement allowance? 102-85.90 Section 102-85.90 Public Contracts and Property Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 85-PRICING POLICY FOR...

  20. 46 CFR 76.33-90 - Installations contracted for prior to November 19, 1952.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false Installations contracted for prior to November 19, 1952. 76.33-90 Section 76.33-90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Smoke Detecting System, Details § 76.33-90 Installations contracted for...

  1. 46 CFR 76.33-90 - Installations contracted for prior to November 19, 1952.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 3 2013-10-01 2013-10-01 false Installations contracted for prior to November 19, 1952. 76.33-90 Section 76.33-90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Smoke Detecting System, Details § 76.33-90 Installations contracted for...

  2. 46 CFR 76.33-90 - Installations contracted for prior to November 19, 1952.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 3 2012-10-01 2012-10-01 false Installations contracted for prior to November 19, 1952. 76.33-90 Section 76.33-90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Smoke Detecting System, Details § 76.33-90 Installations contracted for...

  3. 46 CFR 76.33-90 - Installations contracted for prior to November 19, 1952.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 3 2014-10-01 2014-10-01 false Installations contracted for prior to November 19, 1952. 76.33-90 Section 76.33-90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Smoke Detecting System, Details § 76.33-90 Installations contracted for...

  4. 46 CFR 76.35-90 - Installations contracted for prior to November 19, 1952.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 3 2013-10-01 2013-10-01 false Installations contracted for prior to November 19, 1952. 76.35-90 Section 76.35-90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-90 Installations contracted for...

  5. 46 CFR 76.35-90 - Installations contracted for prior to November 19, 1952.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 3 2012-10-01 2012-10-01 false Installations contracted for prior to November 19, 1952. 76.35-90 Section 76.35-90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-90 Installations contracted for...

  6. 46 CFR 76.35-90 - Installations contracted for prior to November 19, 1952.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 3 2014-10-01 2014-10-01 false Installations contracted for prior to November 19, 1952. 76.35-90 Section 76.35-90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-90 Installations contracted for...

  7. 46 CFR 76.35-90 - Installations contracted for prior to November 19, 1952.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false Installations contracted for prior to November 19, 1952. 76.35-90 Section 76.35-90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-90 Installations contracted for...

  8. First-Principles Study on the Gilbert Damping Constants of Transition Metal Alloys, Fe--Ni and Fe--Pt Systems

    NASA Astrophysics Data System (ADS)

    Sakuma, Akimasa

    2012-08-01

    We adapt the tight-binding linear muffin-tin orbital (TB-LMTO) method to the torque-correlation model for the Gilbert damping constant α and perform the first-principles calculation for disordered transition metal alloys, Fe--Ni and Fe--Pt systems, within the framework of the CPA. Quantitatively, the calculated α values are about one-half of the experimental values, whereas the variations in the Fermi level dependence of α are much larger than these discrepancies. As expected, we confirm in the (Fe--Ni)1-XPtX and FePt systems that Pt atoms certainly enhance α owing to their large spin--orbit coupling. For the disordered alloys, we find that α decreases with increasing chemical degree of order in a wide range.

  9. 40 CFR 90.206 - Trading.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Trading. 90.206 Section 90.206... Trading Provisions § 90.206 Trading. (a) An engine manufacturer may exchange emission credits with other engine manufacturers in trading, subject to the trading restriction specified in § 90.207(c)(2). (b...

  10. 40 CFR 90.206 - Trading.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Trading. 90.206 Section 90.206... Trading Provisions § 90.206 Trading. (a) An engine manufacturer may exchange emission credits with other engine manufacturers in trading, subject to the trading restriction specified in § 90.207(c)(2). (b...

  11. 40 CFR 90.206 - Trading.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Trading. 90.206 Section 90.206... Trading Provisions § 90.206 Trading. (a) An engine manufacturer may exchange emission credits with other engine manufacturers in trading, subject to the trading restriction specified in § 90.207(c)(2). (b...

  12. 40 CFR 90.206 - Trading.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Trading. 90.206 Section 90.206... Trading Provisions § 90.206 Trading. (a) An engine manufacturer may exchange emission credits with other engine manufacturers in trading, subject to the trading restriction specified in § 90.207(c)(2). (b...

  13. 40 CFR 90.206 - Trading.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Trading. 90.206 Section 90.206... Trading Provisions § 90.206 Trading. (a) An engine manufacturer may exchange emission credits with other engine manufacturers in trading, subject to the trading restriction specified in § 90.207(c)(2). (b...

  14. Larson-Miller Constant of Heat-Resistant Steel

    NASA Astrophysics Data System (ADS)

    Tamura, Manabu; Abe, Fujio; Shiba, Kiyoyuki; Sakasegawa, Hideo; Tanigawa, Hiroyasu

    2013-06-01

    Long-term rupture data for 79 types of heat-resistant steels including carbon steel, low-alloy steel, high-alloy steel, austenitic stainless steel, and superalloy were analyzed, and a constant for the Larson-Miller (LM) parameter was obtained in the current study for each material. The calculated LM constant, C, is approximately 20 for heat-resistant steels and alloys except for high-alloy martensitic steels with high creep resistance, for which C ≈ 30 . The apparent activation energy was also calculated, and the LM constant was found to be proportional to the apparent activation energy with a high correlation coefficient, which suggests that the LM constant is a material constant possessing intrinsic physical meaning. The contribution of the entropy change to the LM constant is not small, especially for several martensitic steels with large values of C. Deformation of such martensitic steels should accompany a large entropy change of 10 times the gas constant at least, besides the entropy change due to self-diffusion.

  15. Motion in a central field in the presence of a constant perturbing acceleration in a co-moving coordinate system

    NASA Astrophysics Data System (ADS)

    Sannikova, T. N.; Kholshevnikov, K. V.

    2015-08-01

    The motion of a point mass under the action of a gravitational force toward a central body and a perturbing acceleration P is considered. The magnitude of P is taken to be small compared to the main gravitational acceleration due to the central body, and the direction of P to be constant in a standard astronomical coordinate system with its origin at the central body and axes directed along the radius vector, the transversal, and the binormal. Consideration of a constant vector perturbing acceleration simplifies averaging of the Euler equations for the motion in osculating elements, making it straightforward to obtain evolutionary differential equations of motion in the mean elements, as was done earlier in a first small-parameter approximation. This paper is devoted to integration of the mean equations. The system is integratable by quadratures if at least one component of the perturbing acceleration is zero, and also if the orbit is initially circular. Moreover, all the quadratures can be expressed in terms of elementary functions and elliptical integrals of the first kind in Jacobi form. If all three components of P are non-zero, this problem reduces to a system of two first-order differential equations, which are apparently not integrable. Possible applications include the motion of natural and artificial satellites taking into account light pressure, the motion of a spacecraft with low thrust, and the motion of an asteroid subject to a thrust from an engine mounted on it or to a gravitational tractor designed, for example, to avoid a collision with Earth.

  16. 47 CFR 90.912 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Definitions. 90.912 Section 90.912....912 Definitions. (a) Scope. The definitions in this section apply to §§ 90.910 and 90.911, unless otherwise specified in those sections. (b) Small and very small businesses. (1) A small business is an...

  17. Radioembolization and the Dynamic Role of 90Y PET/CT

    PubMed Central

    Pasciak, Alexander S.; Bourgeois, Austin C.; McKinney, J. Mark; Chang, Ted T.; Osborne, Dustin R.; Acuff, Shelley N.; Bradley, Yong C.

    2014-01-01

    Before the advent of tomographic imaging, it was postulated that decay of 90 Y to the 0+ excited state of 90Zr may result in emission of a positron–electron pair. While the branching ratio for pair-production is small (~32 × 10−6), PET has been successfully used to image 90 Y in numerous recent patients and phantom studies. 90 Y PET imaging has been performed on a variety of PET/CT systems, with and without time-of-flight (TOF) and/or resolution recovery capabilities as well as on both bismuth-germanate and lutetium yttrium orthosilicate (LYSO)-based scanners. On all systems, resolution and contrast superior to bremsstrahlung SPECT has been reported. The intrinsic radioactivity present in LYSO-based PET scanners is a potential limitation associated with accurate quantification of 90 Y. However, intrinsic radioactivity has been shown to have a negligible effect at the high activity concentrations common in 90 Y radioembolization. Accurate quantification is possible on a variety of PET scanner models, with or without TOF, although TOF improves accuracy at lower activity concentrations. Quantitative 90 Y PET images can be transformed into 3-dimensional (3D) maps of absorbed dose based on the premise that the 90 Y activity distribution does not change after infusion. This transformation has been accomplished in several ways, although the most common is with the use of 3D dose-point-kernel convolution. From a clinical standpoint, 90 Y PET provides a superior post-infusion evaluation of treatment technical success owing to its improved resolution. Absorbed dose maps generated from quantitative PET data can be used to predict treatment efficacy and manage patient follow-up. For patients who receive multiple treatments, this information can also be used to provide patient-specific treatment-planning for successive therapies, potentially improving response. The broad utilization of 90 Y PET has the potential to provide a wealth of dose

  18. Modified large number theory with constant G

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Recami, E.

    1983-03-01

    The inspiring ''numerology'' uncovered by Dirac, Eddington, Weyl, et al. can be explained and derived when it is slightly modified so to connect the ''gravitational world'' (cosmos) with the ''strong world'' (hadron), rather than with the electromagnetic one. The aim of this note is to show the following. In the present approach to the ''Large Number Theory,'' cosmos and hadrons are considered to be (finite) similar systems, so that the ratio R-bar/r-bar of the cosmos typical length R-bar to the hadron typical length r-bar is constant in time (for instance, if both cosmos and hadrons undergo an expansion/contraction cycle: accordingmore » to the ''cyclical big-bang'' hypothesis: then R-bar and r-bar can be chosen to be the maximum radii, or the average radii). As a consequence, then gravitational constant G results to be independent of time. The present note is based on work done in collaboration with P.Caldirola, G. D. Maccarrone, and M. Pavsic.« less

  19. Intraprocedural yttrium-90 positron emission tomography/CT for treatment optimization of yttrium-90 radioembolization.

    PubMed

    Bourgeois, Austin C; Chang, Ted T; Bradley, Yong C; Acuff, Shelley N; Pasciak, Alexander S

    2014-02-01

    Radioembolization with yttrium-90 ((90)Y) microspheres relies on delivery of appropriate treatment activity to ensure patient safety and optimize treatment efficacy. We report a case in which (90)Y positron emission tomography (PET)/computed tomography (CT) was performed to optimize treatment planning during a same-day, three-part treatment session. This treatment consisted of (i) an initial (90)Y infusion with a dosage determined using an empiric treatment planning model, (ii) quantitative (90)Y PET/CT imaging, and (iii) a secondary infusion with treatment planning based on quantitative imaging data with the goal of delivering a specific total tumor absorbed dose. © 2014 SIR Published by SIR All rights reserved.

  20. Advances in the analysis and design of constant-torque springs

    NASA Technical Reports Server (NTRS)

    McGuire, John R.; Yura, Joseph A.

    1996-01-01

    In order to improve the design procedure of constant-torque springs used in aerospace applications, several new analysis techniques have been developed. These techniques make it possible to accurately construct a torque-rotation curve for any general constant-torque spring configuration. These new techniques allow for friction in the system to be included in the analysis, an area of analysis that has heretofore been unexplored. The new analysis techniques also include solutions for the deflected shape of the spring as well as solutions for drum and roller support reaction forces. A design procedure incorporating these new capabilities is presented.

  1. 41 CFR 102-38.90 - What is a spot bid sale?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 41 Public Contracts and Property Management 3 2014-01-01 2014-01-01 false What is a spot bid sale? 102-38.90 Section 102-38.90 Public Contracts and Property Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION PERSONAL PROPERTY 38-SALE OF PERSONAL PROPERTY...

  2. 41 CFR 102-38.90 - What is a spot bid sale?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What is a spot bid sale? 102-38.90 Section 102-38.90 Public Contracts and Property Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION PERSONAL PROPERTY 38-SALE OF PERSONAL PROPERTY...

  3. 41 CFR 102-38.90 - What is a spot bid sale?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 41 Public Contracts and Property Management 3 2012-01-01 2012-01-01 false What is a spot bid sale? 102-38.90 Section 102-38.90 Public Contracts and Property Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION PERSONAL PROPERTY 38-SALE OF PERSONAL PROPERTY...

  4. 41 CFR 102-38.90 - What is a spot bid sale?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 41 Public Contracts and Property Management 3 2013-07-01 2013-07-01 false What is a spot bid sale? 102-38.90 Section 102-38.90 Public Contracts and Property Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION PERSONAL PROPERTY 38-SALE OF PERSONAL PROPERTY...

  5. 41 CFR 102-38.90 - What is a spot bid sale?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 41 Public Contracts and Property Management 3 2011-01-01 2011-01-01 false What is a spot bid sale? 102-38.90 Section 102-38.90 Public Contracts and Property Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION PERSONAL PROPERTY 38-SALE OF PERSONAL PROPERTY...

  6. Constant-roll tachyon inflation and observational constraints

    NASA Astrophysics Data System (ADS)

    Gao, Qing; Gong, Yungui; Fei, Qin

    2018-05-01

    For the constant-roll tachyon inflation, we derive the analytical expressions for the scalar and tensor power spectra, the scalar and tensor spectral tilts and the tensor to scalar ratio to the first order of epsilon1 by using the method of Bessel function approximation. The derived ns-r results are compared with the observations, we find that only the constant-roll inflation with ηH being a constant is consistent with the observations and observations constrain the constant-roll inflation to be slow-roll inflation. The tachyon potential is also reconstructed for the constant-roll inflation which is consistent with the observations.

  7. Accurate Determination of the Values of Fundamental Physical Constants: The Basis of the New "Quantum" SI Units

    NASA Astrophysics Data System (ADS)

    Karshenboim, S. G.

    2018-03-01

    The metric system appeared as the system of units designed for macroscopic (laboratory scale) measurements. The progress in accurate determination of the values of quantum constants (such as the Planck constant) in SI units shows that the capabilities in high-precision measurement of microscopic and macroscopic quantities in terms of the same units have increased substantially recently. At the same time, relative microscopic measurements (for example, the comparison of atomic transition frequencies or atomic masses) are often much more accurate than relative measurements of macroscopic quantities. This is the basis for the strategy to define units in microscopic phenomena and then use them on the laboratory scale, which plays a crucial role in practical methodological applications determined by everyday life and technologies. The international CODATA task group on fundamental constants regularly performs an overall analysis of the precision world data (the so-called Adjustment of the Fundamental Constants) and publishes their recommended values. The most recent evaluation was based on the data published by the end of 2014; here, we review the corresponding data and results. The accuracy in determination of the Boltzmann constant has increased, the consistency of the data on determination of the Planck constant has improved; it is these two dimensional constants that will be used in near future as the basis for the new definition of the kelvin and kilogram, respectively. The contradictions in determination of the Rydberg constant and the proton charge radius remain. The accuracy of determination of the fine structure constant and relative atomic weight of the electron has improved. Overall, we give a detailed review of the state of the art in precision determination of the values of fundamental constants. The mathematical procedure of the Adjustment, the new data and results are considered in detail. The limitations due to macroscopic properties of material

  8. Graviton fluctuations erase the cosmological constant

    NASA Astrophysics Data System (ADS)

    Wetterich, C.

    2017-10-01

    Graviton fluctuations induce strong non-perturbative infrared renormalization effects for the cosmological constant. The functional renormalization flow drives a positive cosmological constant towards zero, solving the cosmological constant problem without the need to tune parameters. We propose a simple computation of the graviton contribution to the flow of the effective potential for scalar fields. Within variable gravity, with effective Planck mass proportional to the scalar field, we find that the potential increases asymptotically at most quadratically with the scalar field. The solutions of the derived cosmological equations lead to an asymptotically vanishing cosmological "constant" in the infinite future, providing for dynamical dark energy in the present cosmological epoch. Beyond a solution of the cosmological constant problem, our simplified computation also entails a sizeable positive graviton-induced anomalous dimension for the quartic Higgs coupling in the ultraviolet regime, substantiating the successful prediction of the Higgs boson mass within the asymptotic safety scenario for quantum gravity.

  9. National responses to global health targets: exploring policy transfer in the context of the UNAIDS '90-90-90' treatment targets in Ghana and Uganda.

    PubMed

    McRobie, Ellen; Matovu, Fred; Nanyiti, Aisha; Nonvignon, Justice; Abankwah, Daniel Nana Yaw; Case, Kelsey K; Hallett, Timothy B; Hanefeld, Johanna; Conteh, Lesong

    2018-01-01

    Global health organizations frequently set disease-specific targets with the goal of eliciting adoption at the national-level; consideration of the influence of target setting on national policies, programme and health budgets is of benefit to those setting targets and those intended to respond. In 2014, the Joint United Nations Programme on HIV/AIDS set 'ambitious' treatment targets for country adoption: 90% of HIV-positive persons should know their status; 90% of those on treatment; 90% of those achieving viral suppression. Using case studies from Ghana and Uganda, we explore how the target and its associated policy content have been adopted at the national level. That is whether adoption is in rhetoric only or supported by programme, policy or budgetary changes. We review 23 (14 from Ghana, 9 from Uganda) national policy, operational and strategic documents for the HIV response and assess commitments to '90-90-90'. In-person semi-structured interviews were conducted with purposively sampled key informants (17 in Ghana, 20 in Uganda) involved in programme-planning and resource allocation within HIV to gain insight into factors facilitating adoption of 90-90-90. Interviews were transcribed and analysed thematically, inductively and deductively, guided by pre-existing policy theories, including Dolowitz and Marsh's policy transfer framework to describe features of the transfer and the Global Health Advocacy and Policy Project framework to explain observations. Regardless of notable resource constraints, transfer of the 90-90-90 targets was evident beyond rhetoric with substantial shifts in policy and programme activities. In both countries, there was evidence of attempts to minimize resource constraints by seeking programme efficiencies, prioritization of programme activities and devising domestic financing mechanisms; however, significant resource gaps persist. An effective health network, comprised of global and local actors, mediated the adoption and adaptation

  10. The Forgotten 90%: Adult Nonparticipation in Education

    ERIC Educational Resources Information Center

    Patterson, Margaret Becker

    2018-01-01

    Despite a highly developed U.S. adult education system, 90% of adults aged 20 years and older considered the least educated did not participate recently in formal or nonformal education. What are nonparticipants' characteristics, learning backgrounds, and skill levels? What predicts their likelihood of "not" participating in recent…

  11. 47 CFR 90.243 - Mobile relay stations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND... Service. (b) Special provisions for mobile relay operations: (1) In the Public Safety Pool, systems operating on any of the public safety frequencies listed in § 90.20(c) are permitted to be cross-banded for...

  12. Effectively delivering a unique hsp90 inhibitor using star polymers.

    PubMed

    Kim, Seong Jong; Ramsey, Deborah M; Boyer, Cyrille; Davis, Thomas P; McAlpine, Shelli R

    2013-07-25

    We report the synthesis of a novel heat shock protein 90 (hsp90) inhibitor conjugated to a star polymer. Using reversible addition-fragmentation chain-transfer (RAFT) polymerization, we prepared star polymers comprised of PEG attached to a predesigned functional core. The stars were cross-linked using disulfide linkers, and a tagged version of our hsp90 inhibitor was conjugated to the polymer core to generate nanoparticles (14 nM). Dynamic light scattering showed that the nanoparticles were stable in cell growth media for 5 days, and HPLC analysis of compound-release at 3 different pH values showed that release was pH dependent. Cell cytotoxicity studies and confocal microscopy verify that our hsp90 inhibitor was delivered to cells using this nanoparticle delivery system. Further, delivery of our hsp90 inhibitor using star polymer induces apoptosis by a caspase 3-dependent pathway. These studies show that we can deliver our hsp90 inhibitor effectively using star polymers, and induce apoptosis by the same pathway as the parent compound.

  13. Effects of Constant Flow vs. Constant Pressure Perfusion on Fluid Filtration in Severe Hypothermic Isolated Blood-Perfused Rat Lungs.

    PubMed

    Halsøy, Kathrine; Kondratiev, Timofey; Tveita, Torkjel; Bjertnaes, Lars J

    2016-01-01

    Victims of severe accidental hypothermia are prone to fluid extravasation but rarely develop lung edema. We hypothesize that combined hypothermia-induced increase in pulmonary vascular resistance (PVR) and a concomitant fall in cardiac output protect the lungs against edema development. Our aim was to explore in hypothermic-isolated blood-perfused rat lungs whether perfusion at constant pressure influences fluid filtration differently from perfusion at constant flow. Isolated blood-perfused rat lungs were hanging freely in a weight transducer for measuring weight changes (ΔW). Fluid filtration coefficient (Kfc), was determined by transiently elevating left atrial pressure (Pla) by 5.8 mmHg two times each during normothermia (37°C) and during hypothermia (15°C). The lung preparations were randomized to two groups. One group was perfused with constant flow (Constant flow group) and the other group with constant pulmonary artery pressure (Constant PPA group). Microvascular pressure (Pmv) was determined before and during elevation of Pla (ΔPmv) by means of the double occlusion technique. Kfc was calculated with the formula Kfc = ΔW/ΔPmv/min. All Kfc values were normalized to predicted lung weight (P LW ), which was based on body weight (BW) according to the formula: P LW  = 0.0053 BW - 0.48 and presented as Kfc PLW in mg/min/mmHg/g. At cessation, bronchoalveolar lavage (BAL) fluid/perfusate protein concentration (B/P) ratio was determined photometrically. Data were analyzed with parametric or non-parametric tests as appropriate. p  < 0.05 considered as significant. Perfusate flow remained constant in the Constant flow group, but was more than halved during hypothermia in the Constant PPA group concomitant with a more fold increase in PVR. In the Constant flow group, Kfc PLW and B/P ratio increased significantly by more than 10-fold during hypothermia concerted by visible signs of edema in the trachea. Hemoglobin and hematocrit increased within

  14. Tumor-Intrinsic and Tumor-Extrinsic Factors Impacting Hsp90-Targeted Therapy

    PubMed Central

    Alarcon, S. V.; Mollapour, M.; Lee, M.-J.; Tsutsumi, S.; Lee, S.; Kim, Y. S.; Prince, T.; Apolo, A.; Giaccone, G.; Xu, W.; Neckers, L. M.; Trepel, J. B.

    2012-01-01

    In 1994 the first heat shock protein 90 (Hsp90) inhibitor was identified and Hsp90 was reported to be a target for anticancer therapeutics. In the past 18 years there have been 17 distinct Hsp90 inhibitors entered into clinical trial, and the small molecule Hsp90 inhibitors have been highly valuable as probes of the role of Hsp90 and its client proteins in cancer. Although no Hsp90 inhibitor has achieved regulatory approval, recently there has been significant progress in Hsp90 inhibitor clinical development, and in the past year RECIST responses have been documented in HER2-positive breast cancer and EML4-ALK-positive non-small cell lung cancer. All of the clinical Hsp90 inhibitors studied to date are specific in their target, i.e. they bind exclusively to Hsp90 and two related heat shock proteins. However, Hsp90 inhibitors are markedly pleiotropic, causing degradation of over 200 client proteins and impacting critical multiprotein complexes. Furthermore, it has only recently been appreciated that Hsp90 inhibitors can, paradoxically, cause transient activation of the protein kinase clients they are chaperoning, resulting in initiation of signal transduction and significant physiological events in both tumor and tumor microenvironment. An additional area of recent progress in Hsp90 research is in studies of the posttranslational modifications of Hsp90 itself and Hsp90 co-chaperone proteins. Together, a picture is emerging in which the impact of Hsp90 inhibitors is shaped by the tumor intracellular and extracellular milieu, and in which Hsp90 inhibitors impact tumor and host on a microenvironmental and systems level. Here we review the tumor intrinsic and extrinsic factors that impact the efficacy of small molecules engaging the Hsp90 chaperone machine. PMID:22804236

  15. CODATA recommended values of the fundamental constants

    NASA Astrophysics Data System (ADS)

    Mohr, Peter J.; Taylor, Barry N.

    2000-11-01

    A review is given of the latest Committee on Data for Science and Technology (CODATA) adjustment of the values of the fundamental constants. The new set of constants, referred to as the 1998 values, replaces the values recommended for international use by CODATA in 1986. The values of the constants, and particularly the Rydberg constant, are of relevance to the calculation of precise atomic spectra. The standard uncertainty (estimated standard deviation) of the new recommended value of the Rydberg constant, which is based on precision frequency metrology and a detailed analysis of the theory, is approximately 1/160 times the uncertainty of the 1986 value. The new set of recommended values as well as a searchable bibliographic database that gives citations to the relevant literature is available on the World Wide Web at physics.nist.gov/constants and physics.nist.gov/constantsbib, respectively. .

  16. Extracting Diffusion Constants from Echo-Time-Dependent PFG NMR Data Using Relaxation-Time Information

    NASA Astrophysics Data System (ADS)

    Vandusschoten, D.; Dejager, P. A.; Vanas, H.

    Heterogeneous (bio)systems are often characterized by several water-containing compartments that differ in relaxation time values and diffusion constants. Because of the relatively small differences among these diffusion constants, nonoptimal measuring conditions easily lead to the conclusion that a single diffusion constant suffices to describe the water mobility in a heterogeneous (bio)system. This paper demonstrates that the combination of a T2 measurement and diffusion measurements at various echo times (TE), based on the PFG MSE sequence, enables the accurate determination of diffusion constants which are less than a factor of 2 apart. This new method gives errors of the diffusion constant below 10% when two fractions are present, while the standard approach of a biexponential fit to the diffusion data in identical circumstances gives larger (>25%) errors. On application of this approach to water in apple parenchyma tissue, the diffusion constant of water in the vacuole of the cells ( D = 1.7 × 10 -9 m 2/s) can be distinguished from that of the cytoplasm ( D = 1.0 × 10 -9 m 2/s). Also, for mung bean seedlings, the cell size determined by PFG MSE measurements increased from 65 to 100 μm when the echo time increased from 150 to 900 ms, demonstrating that the interpretation of PFG SE data used to investigate cell sizes is strongly dependent on the T2 values of the fractions within the sample. Because relaxation times are used to discriminate the diffusion constants, we propose to name this approach diffusion analysis by relaxation- time- separated (DARTS) PFG NMR.

  17. Ground State of the Universe and the Cosmological Constant. A Nonperturbative Analysis.

    PubMed

    Husain, Viqar; Qureshi, Babar

    2016-02-12

    The physical Hamiltonian of a gravity-matter system depends on the choice of time, with the vacuum naturally identified as its ground state. We study the expanding Universe with scalar field in the volume time gauge. We show that the vacuum energy density computed from the resulting Hamiltonian is a nonlinear function of the cosmological constant and time. This result provides a new perspective on the relation between time, the cosmological constant, and vacuum energy.

  18. Study of kinetic desorption rate constant in fish muscle and agarose gel model using solid phase microextraction coupled with liquid chromatography with tandem mass spectrometry.

    PubMed

    Togunde, Oluranti Paul; Oakes, Ken; Servos, Mark; Pawliszyn, Janusz

    2012-09-12

    This study aims to use solid phase microextraction (SPME), a simple tool to investigate diffusion rate (time) constant of selected pharmaceuticals in gel and fish muscle by comparing desorption rate of diffusion of the drugs in both agarose gel prepared with phosphate-buffered saline (PBS; pH 7.4) and fish muscle. The gel concentration (agarose gel model) that could be used to simulate tissue matrix (fish muscle) for free diffusion of drugs under in vitro and in vivo conditions was determined to model mass transfer phenomena between fibre polymer coating and environmental matrix such that partition coefficients and desorption time constant (diffusion coefficient) can be determined. SPME procedure involves preloading the extraction phase (fibre) with the standards from spiked PBS for 1h via direct extraction. Subsequently, the preloaded fibre is introduced to the sample such fish or agarose gel for specified time ranging from 0.5 to 60 h. Then, fibre is removed at specified time and desorbed in 100 μL of desorption solution (acetonitrile: water 1:1) for 90 min under agitation speed of 1000 rpm. The samples extract were immediately injected to the instrument and analysed using liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS). The limit of detection of the method in gel and fish muscle was 0.01-0.07 ng mL(-1) and 0.07-0.34 ng g(-1), respectively, while the limit quantification was 0.10-0.20 ng mL(-1) in gel samples and 0.40-0.97 ng g(-1) in fish sample. The reproducibility of the method was good (5-15% RSD). The results suggest that kinetics of desorption of the compounds in fish tissue and different viscosity of gel can be determined using desorption time constant. In this study, desorption time constant which is directly related to desorption rate (diffusion kinetics) of selected drugs from the fibre to the gel matrix is faster as the viscosity of the gel matrix reduces from 2% (w/v) to 0.8% (w/v). As the concentration of gel reduces

  19. Advances in the clinical development of heat shock protein 90 (Hsp90) inhibitors in cancers

    PubMed Central

    Jhaveri, Komal; Taldone, Tony; Modi, Shanu; Chiosis, Gabriela

    2011-01-01

    Hsp90 is an ATP dependent molecular chaperone protein which integrates multiple oncogenic pathways. As such, Hsp90 inhibition is a promising anti-cancer strategy. Several inhibitors that act on Hsp90 by binding to its N-terminal ATP pocket have entered clinical evaluation. Robust pre-clinical data suggested anti-tumor activity in multiple cancer types. Clinically, encouraging results have been demonstrated in melanoma, acute myeloid leukemia, castrate refractory prostate cancer, non-small cell lung carcinoma and multiple myeloma. In breast cancer, proof-of-concept was demonstrated by first generation Hsp90 inhibitors in combination with trastuzumab mainly in human epidermal growth factor receptor 2 (HER2) + metastatic breast cancer. There are a multitude of second generation Hsp90 inhibitors currently under investigation. To date, however, there is no FDA approved Hsp90 inhibitor nor standardized assay to ascertain Hsp90 inhibition. This review summarizes the current status of both first and second generation Hsp90 inhibitors based on their chemical classification and stage of clinical development. It also discusses the pharmacodynamic assays currently implemented in clinic as well as other novel strategies aimed at enhancing the effectiveness of Hsp90 inhibitors. Ultimately, these efforts will aid in maximizing the full potential of this class of agents. PMID:22062686

  20. Water Relations, Gas Exchange, and Nutrient Response to a Long Term Constant Water Deficit

    NASA Technical Reports Server (NTRS)

    Berry, Wade L.; Goldstein, Guillermo; Dreschel, Thomas W.; Wheeler, Raymond M.; Sager, John C.; Knott, William M.

    1992-01-01

    Wheat plants (Triticum aestivum) were grown for 43 days in a micro-porous tube nutrient delivery system. Roots were unable to penetrate the microporous tube, but grew on the surface and maintained capillary contact with the nutrient solution on the inside of the tube through the 5-micron pores of the porous tube. Water potential in the system was controlled at -0.4, -0.8, and -3.0 kPa by adjusting the applied pressure (hydrostatic head) to the nutrient solution flowing through the microporous tubes. A relatively small decrease in applied water potential from -0.4 to -3.0 kPa resulted in a 34% reduction of shoot growth but only a moderate reduction in the midday leaf water potential from -1.3 to -1.7 MPa. Carbon dioxide assimilation decreased and water use efficiency increased with the more negative applied water potentials, while intercellular CO2 concentration remained constant. This was associated with a decrease in stomatal conductance to water vapor from 1.90 to 0.98 mol/(sq m sec) and a decrease in total apparent hydraulic conductance from 47 to 12 (micro)mol/(sec MPa). Although the applied water potentials were in the -0.4 to -3.0 kPa range, the actual water potential perceived by the plant roots appeared to be in the range of -0.26 to -0.38 MPa as estimated by the leaf water potential of bagged plants. The amount of K, Ca, Mg, Zn, Cu, and B accumulated with each unit of transpired water increased as the applied water potential became less negative. The increase in accumulation ranged from 1.4-fold for K to 2.2-fold for B. The physiological responses observed in this study in response to small constant differences in applied water potentials were much greater than expected from either the applied water potential or the observed plant water potential. Even though the micro-porous tube may not represent natural conditions and could possibly introduce morphological and physiological artifacts, it enables a high degree of control of water potential that

  1. Weak signal detection: A discrete window of opportunity for achieving ‘Vision 90:90:90’?

    PubMed Central

    Burman, Christopher J.; Aphane, Marota; Delobelle, Peter

    2016-01-01

    Abstract Introduction: UNAIDS’ Vision 90:90:90 is a call to ‘end AIDS’. Developing predictive foresight of the unpredictable changes that this journey will entail could contribute to the ambition of ‘ending AIDS’. There are few opportunities for managing unpredictable changes. We introduce ‘weak signal detection’ as a potential opportunity to fill this void. Method: Combining futures and complexity theory, we reflect on two pilot case studies that involved the Archetype Extraction technique and the SenseMaker® Collector™ tool. Results: Both the piloted techniques have the potentials to surface weak signals – but there is room for improvement. Discussion: A management response to a complex weak signal requires pattern management, rather than an exclusive focus on behaviour management. Conclusion: Weak signal detection is a window of opportunity to improve resilience to unpredictable changes in the HIV/AIDS landscape that can both reduce the risk that emerges from the changes and increase the visibility of opportunities to exploit the unpredictable changes that could contribute to ‘ending AIDS’. PMID:26821952

  2. Elastic constants and dynamics in nematic liquid crystals

    NASA Astrophysics Data System (ADS)

    Humpert, Anja; Allen, Michael P.

    2015-09-01

    In this paper, we present molecular dynamics calculations of the Frank elastic constants, and associated time correlation functions, in nematic liquid crystals. We study two variants of the Gay-Berne potential, and use system sizes of half a million molecules, significantly larger than in previous studies of elastic behaviour. Equilibrium orientational fluctuations in reciprocal (k-) space were calculated, to determine the elastic constants by fitting at low |k|; our results indicate that small system size may be a source of inaccuracy in previous work. Furthermore, the dynamics of the Gay-Berne nematic were studied by calculating time correlation functions of components of the order tensor, together with associated components of the velocity field, for a set of wave vectors k. Confirming our earlier work, we found exponential decay for splay and twist correlations, and oscillatory exponential decay for the bend correlation. In this work, we confirm similar behaviour for the corresponding velocity components. In all cases, the decay rates, and oscillation frequencies, were found to be accurately proportional to k2 for small k, as predicted by the equations of nematodynamics. However, the observation of oscillatory bend fluctuations, and corresponding oscillatory shear flow decay, is in contradiction to the usual assumptions appearing in the literature, and in standard texts. We discuss the advantages and drawbacks of using large systems in these calculations.

  3. Reducing mortality in HIV-infected infants and achieving the 909090 target through innovative diagnosis approaches

    PubMed Central

    Essajee, Shaffiq; Vojnov, Lara; Penazzato, Martina; Jani, Ilesh; Siberry, George K; Fiscus, Susan A; Markby, Jessica

    2015-01-01

    Introduction Despite significant gains in access to early infant diagnosis (EID) over the past decade, most HIV-exposed infants still do not get tested for HIV in the first two months of life. For those who are tested, the long turnaround time between when the sample is drawn and when the results are returned leads to a high rate of loss to follow-up, which in turn means that few infected infants start antiretroviral treatment. Consequently, there continues to be high mortality from perinatally acquired HIV, and the ambitious goals of 90% of infected children identified, 90% of identified children treated and 90% of treated children with sustained virologic suppression by 2020 seem far beyond our reach. The objective of this commentary is to review recent advances in the field of HIV diagnosis in infants and describe how these advances may overcome long-standing barriers to access to testing and treatment. Discussion Several innovative approaches to EID have recently been described. These include point-of-care testing, use of SMS printers to connect the central laboratory and the health facility through a mobile phone network, expanding paediatric testing to other entry points where children access the health system and testing HIV-exposed infants at birth as a rapid way to identify in utero infection. Each of these interventions is discussed here, together with the opportunities and challenges associated with scale-up. Point-of-care testing has the potential to provide immediate results but is less cost-effective in settings where test volumes are low. Virological testing at birth has been piloted in some countries to identify those infants who need urgent treatment, but a negative test at birth does not obviate the need for additional testing at six weeks. Routine testing of infants in child health settings is a useful strategy to identify exposed and infected children whose mothers were not enrolled in programmes for the prevention of mother

  4. New perspectives on constant-roll inflation

    NASA Astrophysics Data System (ADS)

    Cicciarella, Francesco; Mabillard, Joel; Pieroni, Mauro

    2018-01-01

    We study constant-roll inflation using the β-function formalism. We show that the constant rate of the inflaton roll is translated into a first order differential equation for the β-function which can be solved easily. The solutions to this equation correspond to the usual constant-roll models. We then construct, by perturbing these exact solutions, more general classes of models that satisfy the constant-roll equation asymptotically. In the case of an asymptotic power law solution, these corrections naturally provide an end to the inflationary phase. Interestingly, while from a theoretical point of view (in particular in terms of the holographic interpretation) these models are intrinsically different from standard slow-roll inflation, they may have phenomenological predictions in good agreement with present cosmological data.

  5. 12 CFR 222.90 - Duties regarding the detection, prevention, and mitigation of identity theft.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... mitigation of identity theft. 222.90 Section 222.90 Banks and Banking FEDERAL RESERVE SYSTEM (CONTINUED...) Identity Theft Red Flags § 222.90 Duties regarding the detection, prevention, and mitigation of identity... soundness of the financial institution or creditor from identity theft, including financial, operational...

  6. 12 CFR 222.90 - Duties regarding the detection, prevention, and mitigation of identity theft.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... mitigation of identity theft. 222.90 Section 222.90 Banks and Banking FEDERAL RESERVE SYSTEM (CONTINUED...) Identity Theft Red Flags § 222.90 Duties regarding the detection, prevention, and mitigation of identity... soundness of the financial institution or creditor from identity theft, including financial, operational...

  7. Targeting Hsp90-Cdc37: A Promising Therapeutic Strategy by Inhibiting Hsp90 Chaperone Function.

    PubMed

    Wang, Lei; Li, Li; Gu, Kai; Xu, Xiao-Li; Sun, Yuan; You, Qi-Dong

    2017-01-01

    The Hsp90 chaperone protein regulates the folding, maturation and stability of a wide variety of oncoproteins. In recent years, many Hsp90 inhibitors have entered into the clinical trials while all of them target ATPase showing similar binding capacity and kinds of side-effects so that none have reached to the market. During the regulation progress, numerous protein- protein interactions (PPI) such as Hsp90 and client proteins or cochaperones are involved. With the Hsp90-cochaperones PPI networks being more and more clear, many cancerous proteins have been reported to be tightly correlated to Hsp90-cochaperones PPI. Among them, Hsp90-Cdc37 PPI has been widely reported to associate with numerous protein kinases, making it a novel target for the treatment of cancers. In this paper, we briefly review the strategies and modulators targeting Hsp90-Cdc37 complex including direct and indirect regulation mechanism. Through these discussions we expect to present inspirations for new insights into an alternative way to inhibit Hsp90 chaperone function. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  8. Defense Small Business Innovation Research (SBIR) Program. Program Solicitation 90.1. FY-1990

    DTIC Science & Technology

    1989-10-01

    Electronics Assemble and Test A90-125 Guided-Wave TeO2 Optical Devices A90-126 Acceleration Sensing Module for Munition Safety Systems A90-127 Electromagnetic...package containing all drawings and process information, complete operating manuals. A90-125 Guided-Wave TeO2 Optical Devices OBJECTIVE: This exploratory...bandwidth and efficiency of these devices. PHASE I: Phase one would consist of the design of several breadboard TeO2 AO devices each having TBWP of

  9. Fine structure constant and quantized optical transparency of plasmonic nanoarrays.

    PubMed

    Kravets, V G; Schedin, F; Grigorenko, A N

    2012-01-24

    Optics is renowned for displaying quantum phenomena. Indeed, studies of emission and absorption lines, the photoelectric effect and blackbody radiation helped to build the foundations of quantum mechanics. Nevertheless, it came as a surprise that the visible transparency of suspended graphene is determined solely by the fine structure constant, as this kind of universality had been previously reserved only for quantized resistance and flux quanta in superconductors. Here we describe a plasmonic system in which relative optical transparency is determined solely by the fine structure constant. The system consists of a regular array of gold nanoparticles fabricated on a thin metallic sublayer. We show that its relative transparency can be quantized in the near-infrared, which we attribute to the quantized contact resistance between the nanoparticles and the metallic sublayer. Our results open new possibilities in the exploration of universal dynamic conductance in plasmonic nanooptics.

  10. Voicing produced by a constant velocity lung source

    PubMed Central

    Howe, M. S.; McGowan, R. S.

    2013-01-01

    An investigation is made of the influence of subglottal boundary conditions on the prediction of voiced sounds. It is generally assumed in mathematical models of voicing that vibrations of the vocal folds are maintained by a constant subglottal mean pressure pI, whereas voicing is actually initiated by contraction of the chest cavity until the subglottal pressure becomes large enough to separate the vocal folds. The problem is reformulated to determine voicing characteristics in terms of a prescribed volumetric flow rate Qo of air from the lungs—the evolution of the resulting time-dependent subglottal mean pressure p¯_(t) is then governed by glottal mechanics, the aeroacoustics of the vocal tract, and the influence of continued contraction of the lungs. The new problem is analyzed in detail for an idealized mechanical vocal system that permits precise specification of all boundary conditions. Predictions of the glottal volume velocity pulse shape are found to be in good general agreement with the traditional constant-pI theory when pI is set equal to the time averaged value of p¯_(t). But, in all cases examined the constant-pI approximation yields values of the mean flow rates Qo and sound pressure levels that are smaller by as much as 10%. PMID:23556600

  11. Advanced concepts for transformers pressboard dielectric constant and mechanical strength

    NASA Astrophysics Data System (ADS)

    1982-03-01

    Of the numerous electrical considerations in a material, the value of the dielectric constant serves as an important criterion in designing proper insulation systems. Ways to reduce the dielectric constant of solid (fibrous) insulating materials were investigated. A literature search was made on cellulosic and synthetic fibers and also additives which offered the potential for dielectric constant reduction of the solid insulation. Sample board structures were produced in the laboratory and tested for electrical, mechanical and chemical characteristics. Electrical tests determined the suitability of the material at transformer test and operating conditions. The mechanical tests established the physical characteristics of the modified board structures. Chemical tests checked the conductivity of the aqueous extract, acidity, and ash content. Further, compatibility with transformer oil and some aging tests were performed. An actual computer transformer design was made based on one of the modified board structures and the reduction in core steel and transformer losses were shown.

  12. 47 CFR 90.355 - LMS operations below 512 MHz.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... PRIVATE LAND MOBILE RADIO SERVICES Intelligent Transportation Systems Radio Service § 90.355 LMS... LMS station and the nearest co-channel base station of another licensee operating a voice system is 75... MHz, 150-170 MHz, and 450-512 MHz bands may use either base-mobile frequencies currently assigned the...

  13. 40 CFR 86.142-90 - Records required.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... period and at the end of each sample period. (5) The stabilized pre-test weight and post-test weight of...-Duty Vehicles; Test Procedures § 86.142-90 Records required. The following information shall be recorded with respect to each test: (a) Test number. (b) System or device tested (brief description). (c...

  14. 40 CFR 86.142-90 - Records required.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... period and at the end of each sample period. (5) The stabilized pre-test weight and post-test weight of...-Duty Vehicles; Test Procedures § 86.142-90 Records required. The following information shall be recorded with respect to each test: (a) Test number. (b) System or device tested (brief description). (c...

  15. 40 CFR 86.142-90 - Records required.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... period and at the end of each sample period. (5) The stabilized pre-test weight and post-test weight of...-Duty Vehicles; Test Procedures § 86.142-90 Records required. The following information shall be recorded with respect to each test: (a) Test number. (b) System or device tested (brief description). (c...

  16. 40 CFR 86.142-90 - Records required.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... period and at the end of each sample period. (5) The stabilized pre-test weight and post-test weight of...-Duty Vehicles; Test Procedures § 86.142-90 Records required. The following information shall be recorded with respect to each test: (a) Test number. (b) System or device tested (brief description). (c...

  17. 40 CFR 86.142-90 - Records required.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... period and at the end of each sample period. (5) The stabilized pre-test weight and post-test weight of...-Duty Vehicles; Test Procedures § 86.142-90 Records required. The following information shall be recorded with respect to each test: (a) Test number. (b) System or device tested (brief description). (c...

  18. Immune activation underlies a sustained clinical response to Yttrium-90 radioembolisation in hepatocellular carcinoma.

    PubMed

    Chew, Valerie; Lee, Yun Hua; Pan, Lu; Nasir, Nurul J M; Lim, Chun Jye; Chua, Camillus; Lai, Liyun; Hazirah, Sharifah Nur; Lim, Tony Kiat Hon; Goh, Brian K P; Chung, Alexander; Lo, Richard H G; Ng, David; Filarca, Rene L F; Albani, Salvatore; Chow, Pierce K H

    2018-02-13

    Yttrium-90 (Y90)-radioembolisation (RE) significantly regresses locally advanced hepatocellular carcinoma and delays disease progression. The current study is designed to deeply interrogate the immunological impact of Y90-RE, which elicits a sustained therapeutic response. Time-of-flight mass cytometry and next-generation sequencing (NGS) were used to analyse the immune landscapes of tumour-infiltrating leucocytes (TILs), tumour tissues and peripheral blood mononuclear cells (PBMCs) at different time points before and after Y90-RE. TILs isolated after Y90-RE exhibited signs of local immune activation: higher expression of granzyme B (GB) and infiltration of CD8 + T cells, CD56 + NK cells and CD8 + CD56 + NKT cells. NGS confirmed the upregulation of genes involved in innate and adaptive immune activation in Y90-RE-treated tumours. Chemotactic pathways involving CCL5 and CXCL16 correlated with the recruitment of activated GB + CD8 + T cells to the Y90-RE-treated tumours. When comparing PBMCs before and after Y90-RE, we observed an increase in tumour necrosis factor-α on both the CD8 + and CD4 + T cells as well as an increase in percentage of antigen-presenting cells after Y90-RE, implying a systemic immune activation. Interestingly, a high percentage of PD-1 + /Tim-3 + CD8 + T cells coexpressing the homing receptors CCR5 and CXCR6 denoted Y90-RE responders. A prediction model was also built to identify sustained responders to Y90-RE based on the immune profiles from pretreatment PBMCs. High-dimensional analysis of tumour and systemic immune landscapes identified local and systemic immune activation that corresponded to the sustained response to Y90-RE. Potential biomarkers associated with a positive clinical response were identified and a prediction model was built to identify sustained responders prior to treatment. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is

  19. 47 CFR 22.970 - Unacceptable interference to part 90 non-cellular 800 MHz licensees from cellular radiotelephone...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...-cellular 800 MHz licensees from cellular radiotelephone or part 90-800 MHz cellular systems. 22.970 Section... MOBILE SERVICES Cellular Radiotelephone Service § 22.970 Unacceptable interference to part 90 non-cellular 800 MHz licensees from cellular radiotelephone or part 90-800 MHz cellular systems. (a) Definition...

  20. Capacitive Cells for Dielectric Constant Measurement

    ERIC Educational Resources Information Center

    Aguilar, Horacio Munguía; Maldonado, Rigoberto Franco

    2015-01-01

    A simple capacitive cell for dielectric constant measurement in liquids is presented. As an illustrative application, the cell is used for measuring the degradation of overheated edible oil through the evaluation of their dielectric constant.

  1. The Hubble Constant.

    PubMed

    Jackson, Neal

    2015-01-01

    I review the current state of determinations of the Hubble constant, which gives the length scale of the Universe by relating the expansion velocity of objects to their distance. There are two broad categories of measurements. The first uses individual astrophysical objects which have some property that allows their intrinsic luminosity or size to be determined, or allows the determination of their distance by geometric means. The second category comprises the use of all-sky cosmic microwave background, or correlations between large samples of galaxies, to determine information about the geometry of the Universe and hence the Hubble constant, typically in a combination with other cosmological parameters. Many, but not all, object-based measurements give H 0 values of around 72-74 km s -1 Mpc -1 , with typical errors of 2-3 km s -1 Mpc -1 . This is in mild discrepancy with CMB-based measurements, in particular those from the Planck satellite, which give values of 67-68 km s -1 Mpc -1 and typical errors of 1-2 km s -1 Mpc -1 . The size of the remaining systematics indicate that accuracy rather than precision is the remaining problem in a good determination of the Hubble constant. Whether a discrepancy exists, and whether new physics is needed to resolve it, depends on details of the systematics of the object-based methods, and also on the assumptions about other cosmological parameters and which datasets are combined in the case of the all-sky methods.

  2. Flow and volume dependence of rat airway resistance during constant flow inflation and deflation.

    PubMed

    Rubini, Alessandro; Carniel, Emanuele Luigi; Parmagnani, Andrea; Natali, Arturo Nicola

    2011-12-01

    The aim of this study was to measure the flow and volume dependence of both the ohmic and the viscoelastic pressure dissipations of the normal rat respiratory system separately during inflation and deflation. The study was conducted in the Respiratory Physiology Laboratory in our institution. Measurements were obtained for Seven albino Wistar rats of both sexes by using the flow interruption method during constant flow inflations and deflations. Measurements included anesthesia induction, tracheostomy and positioning of a tracheal cannula, positive pressure ventilation, constant flow respiratory system inflations and deflations at two different volumes and flows. The ohmic resistance exhibited volume and flow dependence, decreasing with lung volume and increasing with flow rate, during both inflation and deflation. The stress relaxation-related viscoelastic resistance also exhibited volume and flow dependence. It decreased with the flow rate at a constant lung volume during both inflation and deflation, but exhibited a different behavior with the lung volume at a constant flow rate (i.e., increased during inflations and decreased during deflations). Thus, stress relaxation in the rat lungs exhibited a hysteretic behavior. The observed flow and volume dependence of respiratory system resistance may be predicted by an equation derived from a model of the respiratory system that consists of two distinct compartments. The equation agrees well with the experimental data and indicates that the loading time is the critical parameter on which stress relaxation depends, during both lung inflation and deflation.

  3. MATHEMATICAL CONSTANTS.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, H.P.; Potter, Elinor

    1971-03-01

    This collection of mathematical data consists of two tables of decimal constants arranged according to size rather than function, a third table of integers from 1 to 1000, giving some of their properties, and a fourth table listing some infinite series arranged according to increasing size of the coefficients of the terms. The decimal values of Tables I and II are given to 20 D.

  4. 47 CFR 90.771 - Field strength limits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Policies Governing the Licensing and Use of Phase II Ea, Regional and Nationwide Systems § 90.771 Field... transmit frequencies, of EA and Regional licensees may not exceed a predicted 38 dBu field strength at... required in paragraph (a) of this section if all affected, co-channel EA and Regional licensees agree to...

  5. 47 CFR 90.771 - Field strength limits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Policies Governing the Licensing and Use of Phase II Ea, Regional and Nationwide Systems § 90.771 Field... transmit frequencies, of EA and Regional licensees may not exceed a predicted 38 dBu field strength at... required in paragraph (a) of this section if all affected, co-channel EA and Regional licensees agree to...

  6. The 1% concordance Hubble constant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bennett, C. L.; Larson, D.; Weiland, J. L.

    2014-10-20

    The determination of the Hubble constant has been a central goal in observational astrophysics for nearly a hundred years. Extraordinary progress has occurred in recent years on two fronts: the cosmic distance ladder measurements at low redshift and cosmic microwave background (CMB) measurements at high redshift. The CMB is used to predict the current expansion rate through a best-fit cosmological model. Complementary progress has been made with baryon acoustic oscillation (BAO) measurements at relatively low redshifts. While BAO data do not independently determine a Hubble constant, they are important for constraints on possible solutions and checks on cosmic consistency. Amore » precise determination of the Hubble constant is of great value, but it is more important to compare the high and low redshift measurements to test our cosmological model. Significant tension would suggest either uncertainties not accounted for in the experimental estimates or the discovery of new physics beyond the standard model of cosmology. In this paper we examine in detail the tension between the CMB, BAO, and cosmic distance ladder data sets. We find that these measurements are consistent within reasonable statistical expectations and we combine them to determine a best-fit Hubble constant of 69.6 ± 0.7 km s{sup –1} Mpc{sup –1}. This value is based upon WMAP9+SPT+ACT+6dFGS+BOSS/DR11+H {sub 0}/Riess; we explore alternate data combinations in the text. The combined data constrain the Hubble constant to 1%, with no compelling evidence for new physics.« less

  7. 7 CFR 3015.90 - Scope.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Scope. 3015.90 Section 3015.90 Agriculture Regulations of the Department of Agriculture (Continued) OFFICE OF THE CHIEF FINANCIAL OFFICER, DEPARTMENT OF AGRICULTURE UNIFORM FEDERAL ASSISTANCE REGULATIONS Monitoring and Reporting Program Performance § 3015.90...

  8. 47 CFR 90.1303 - Eligibility.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Eligibility. 90.1303 Section 90.1303 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Wireless Broadband Services in the 3650-3700 MHz Band § 90.1303 Eligibility. Any...

  9. 47 CFR 90.1303 - Eligibility.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Eligibility. 90.1303 Section 90.1303 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Wireless Broadband Services in the 3650-3700 MHz Band § 90.1303 Eligibility. Any...

  10. 47 CFR 90.1303 - Eligibility.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Eligibility. 90.1303 Section 90.1303 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Wireless Broadband Services in the 3650-3700 MHz Band § 90.1303 Eligibility. Any...

  11. 47 CFR 90.111 - Scope.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Scope. 90.111 Section 90.111 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Applications and Authorizations § 90.111 Scope. This subpart supplements title 47, chapter 1...

  12. 46 CFR 195.30-90 - Vessels contracted for before November 23, 1992.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Vessels contracted for before November 23, 1992. 195.30-90 Section 195.30-90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 195...

  13. 46 CFR 195.30-90 - Vessels contracted for before November 23, 1992.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Vessels contracted for before November 23, 1992. 195.30-90 Section 195.30-90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 195...

  14. High-Temperature Slow Crack Growth of Silicon Carbide Determined by Constant-Stress-Rate and Constant-Stress Testing

    NASA Technical Reports Server (NTRS)

    Choi, Sung H.; Salem, J. A.; Nemeth, N. N.

    1998-01-01

    High-temperature slow-crack-growth behaviour of hot-pressed silicon carbide was determined using both constant-stress-rate ("dynamic fatigue") and constant-stress ("static fatigue") testing in flexure at 1300 C in air. Slow crack growth was found to be a governing mechanism associated with failure of the material. Four estimation methods such as the individual data, the Weibull median, the arithmetic mean and the median deviation methods were used to determine the slow crack growth parameters. The four estimation methods were in good agreement for the constant-stress-rate testing with a small variation in the slow-crack-growth parameter, n, ranging from 28 to 36. By contrast, the variation in n between the four estimation methods was significant in the constant-stress testing with a somewhat wide range of n= 16 to 32.

  15. On the ambiguity of the reaction rate constants in multivariate curve resolution for reversible first-order reaction systems.

    PubMed

    Schröder, Henning; Sawall, Mathias; Kubis, Christoph; Selent, Detlef; Hess, Dieter; Franke, Robert; Börner, Armin; Neymeyr, Klaus

    2016-07-13

    If for a chemical reaction with a known reaction mechanism the concentration profiles are accessible only for certain species, e.g. only for the main product, then often the reaction rate constants cannot uniquely be determined from the concentration data. This is a well-known fact which includes the so-called slow-fast ambiguity. This work combines the question of unique or non-unique reaction rate constants with factor analytic methods of chemometrics. The idea is to reduce the rotational ambiguity of pure component factorizations by considering only those concentration factors which are possible solutions of the kinetic equations for a properly adapted set of reaction rate constants. The resulting set of reaction rate constants corresponds to those solutions of the rate equations which appear as feasible factors in a pure component factorization. The new analysis of the ambiguity of reaction rate constants extends recent research activities on the Area of Feasible Solutions (AFS). The consistency with a given chemical reaction scheme is shown to be a valuable tool in order to reduce the AFS. The new methods are applied to model and experimental data. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. 45 CFR 96.90 - Scope.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Scope. 96.90 Section 96.90 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION BLOCK GRANTS Community Services Block Grants § 96.90 Scope. This subpart applies to the community services block grant. ...

  17. 28 CFR 90.58 - Evaluation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Evaluation. 90.58 Section 90.58 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) VIOLENCE AGAINST WOMEN Indian Tribal Governments Discretionary Program § 90.58 Evaluation. The National Institute of Justice will conduct an evaluation of these programs. ...

  18. 7 CFR 3201.90 - Deodorants.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Deodorants. 3201.90 Section 3201.90 Agriculture... Items § 3201.90 Deodorants. (a) Definition. Products that are designed for inhibiting or masking... procurement preference for qualifying biobased deodorants. By that date, Federal agencies that have the...

  19. 7 CFR 3201.90 - Deodorants.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 15 2013-01-01 2013-01-01 false Deodorants. 3201.90 Section 3201.90 Agriculture... Items § 3201.90 Deodorants. (a) Definition. Products that are designed for inhibiting or masking... procurement preference for qualifying biobased deodorants. By that date, Federal agencies that have the...

  20. 28 CFR 90.58 - Evaluation.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Evaluation. 90.58 Section 90.58 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) VIOLENCE AGAINST WOMEN Indian Tribal Governments Discretionary Program § 90.58 Evaluation. The National Institute of Justice will conduct an evaluation of these programs. ...