Abdominal ultrasound and medical education.
García de Casasola Sánchez, G; Torres Macho, J; Casas Rojo, J M; Cubo Romano, P; Antón Santos, J M; Villena Garrido, V; Diez Lobato, R
2014-04-01
Ultrasound is a very versatile diagnostic modality that permits real-time visualization of multiple internal organs. It is of invaluable help for the physical examination of the patients. To assess if ultrasound can be incorporated into medical education and if the students can perform a basic abdominal ultrasound examination without the necessity of a long period of training. Twelve medical students were trained in basic abdominal ultrasound during a 15-h training program including a 5-h theoretical and practical course and supervised practice in 20 selected patients. Subsequently, we conducted an evaluation test that assessed the ability of students to obtain the ultrasound views and to detect various pathologies in five different patients. The students were able to correctly identify the abdominal views more than 90% of the times. This percentage was only lower (80%) in the right subcostal view to locate the gallbladder. The accuracy or global efficiency of the ultrasound for the diagnosis of relevant pathological findings of the patients was greater than 90% (91.1% gallstones, abdominal aortic aneurysm 100%; splenomegaly 98.3%, ascites 100%; dilated inferior vena cava 100%; acute urinary retention 100%). The ultrasound may be a feasible learning tool in medical education. Ultrasound can help students to improve the physical examination. Copyright © 2013 Elsevier España, S.L. All rights reserved.
Abdominal ultrasound is a scanning technique used to image the interior of the abdomen. Like the X-ray, MRI, ... it has its place as a diagnostic tool. Ultrasound scans use high frequency sound waves to produce ...
Ultrasound in the diagnosis of palpable abdominal masses in children.
Annuar, Z; Sakijan, A S; Annuar, N; Kooi, G H
1990-12-01
Ultrasound examinations were done to evaluate clinically palpable abdominal masses in 125 children. The examinations were normal in 21 patients. In 15 patients, the clinically palpable masses were actually anterior abdominal wall abscesses or hematomas. Final diagnosis was available in 87 of 89 patients with intraabdominal masses detected on ultrasound. The majority (71%) were retroperitoneal masses where two-thirds were of renal origin. Ultrasound diagnosis was correct in 68 patients (78%). All cases of hydronephrosis were correctly diagnosed based on characteristic ultrasound appearances. Correct diagnoses of all cases of adrenal hematoma, psoas abscess, liver hematoma, liver abscess and one case of liver metastases were achieved with correlation of relevant clinical information.
The use of ultrasound in the diagnosis of abdominal wall hernias.
Young, J; Gilbert, A I; Graham, M F
2007-08-01
The diagnosis of abdominal wall hernias is not always straightforward and may require additional investigative modalities. Real-time ultrasound is accurate, non-invasive, relatively inexpensive, and readily available. The value of ultrasound as an adjunctive tool in the diagnosis of abdominal wall hernias in both pre-operative and post-operative patients was studied. Retrospective analysis of 200 patients treated at the Hernia Institute of Florida was carried out. In these cases, ultrasound had been used to assist with case management. Patients without previous hernia surgery and those with early and late post-herniorrhaphy complaints were studied. Patients with obvious hernias were excluded. Indications for ultrasound examination included patients with abdominal pain without a palpable hernia, a palpable mass of questionable etiology, and patients with inordinate pain or excessive swelling during the early post-operative period. Patients were treated with surgery or conservative therapy depending on the results of the physical examination and ultrasound studies. Cases in which the ultrasound findings influenced the decision-making process by confirming clinical findings or altering the diagnosis and changing the treatment plan are discussed. Of the 200 patients, 144 complained of pain alone and on physical exam no hernia or mass was palpable. Of these 144 patients with pain alone, 21 had a hernia identified on the US examination and were referred for surgery. The 108 that had a negative ultrasound were treated conservatively with rest, heat, and anti-inflammatory drugs, most often with excellent results. Of the 56 remaining patients who had a mass, with or without pain, 22 had hernias identified by means of ultrasound examination. In the other 34, the etiology of the mass was not a hernia. Abdominal wall ultrasound is a valuable tool in the scheme of management of patients in whom the diagnosis of abdominal wall hernia is unclear. Therapeutic decisions can be
Marsico, Maria; Gabbani, Tommaso; Casseri, Tommaso; Biagini, Maria Rosa
2016-11-01
Ultrasonography is a non-invasive, accurate and low-cost technique used to study the upper abdomen, but it has reduced reliability in the study of the pancreas and retroperitoneum. Simethicone is a well-known emulsifying agent that has been used to improve ultrasonographic visualization. The aim of this study was to identify anthropometric parameters that are able to predict a good response to simethicone in improving ultrasonographic visualization of abdominal structures. One hundred twenty-seven patients were recruited. After basal examination, their anthropometric parameters were collected. Patients with an incomplete upper abdominal examination because of gastrointestinal gas have greater body mass index, waist circumference and abdominal wall thickness. In our study, the best anthropometric parameter for identifying patients with poor visualization at abdominal ultrasound examination is waist circumference. Using a cutoff of 84 cm, we can identify patients with poor visibility at abdominal ultrasound examination (group B) with a sensitivity of 90%. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Initial Experience Using a Telerobotic Ultrasound System for Adult Abdominal Sonography.
Adams, Scott J; Burbridge, Brent E; Badea, Andreea; Langford, Leanne; Vergara, Vincent; Bryce, Rhonda; Bustamante, Luis; Mendez, Ivar M; Babyn, Paul S
2017-08-01
The study sought to assess the feasibility of performing adult abdominal examinations using a telerobotic ultrasound system in which radiologists or sonographers can control fine movements of a transducer and all ultrasound settings from a remote location. Eighteen patients prospectively underwent a conventional sonography examination (using EPIQ 5 [Philips] or LOGIQ E9 [GE Healthcare]) followed by a telerobotic sonography examination (using the MELODY System [AdEchoTech] and SonixTablet [BK Ultrasound]) according to a standardized abdominal imaging protocol. For telerobotic examinations, patients were scanned remotely by a sonographer 2.75 km away. Conventional examinations were read independently from telerobotic examinations. Image quality and acceptability to patients and sonographers was assessed. Ninety-two percent of organs visualized on conventional examinations were sufficiently visualized on telerobotic examinations. Five pathological findings were identified on both telerobotic and conventional examinations, 3 findings were identified using only conventional sonography, and 2 findings were identified using only telerobotic sonography. A paired sample t test showed no significant difference between the 2 modalities in measurements of the liver, spleen, and diameter of the proximal aorta; however, telerobotic assessments overestimated distal aorta and common bile duct diameters and underestimated kidney lengths (P values < .05). All patients responded that they would be willing to have another telerobotic examination. A telerobotic ultrasound system is feasible for performing abdominal ultrasound examinations at a distant location with minimal training and setup requirements and a moderate learning curve. Telerobotic sonography (robotic telesonography) may open up the possibility of remote ultrasound clinics for communities that lack skilled sonographers and radiologists, thereby improving access to care. Copyright © 2016 Canadian Association of
Mai, Trinh; Woo, Michael Y; Boles, Kim; Jetty, Prasad
2018-05-16
To determine the test characteristics of point-of-care ultrasonography performed by a medical student versus physical examination by vascular surgeons compared to a gold standard reference scan for the detection of abdominal aortic aneurysms. We conducted a prospective, observer-blinded study recruiting patients from an outpatient vascular surgery clinic. Participants were screened for abdominal aortic aneurysms by standardized physical examination by a blinded vascular surgeon, followed by a point-of-care ultrasound examination by a blinded medical student. The student underwent prior training by a vascular sonographer and emergency physician on 60 patients (16 were supervised). Ultrasonography was used to visualize and measure the proximal, mid, and distal aortic diameters. The maximal aortic diameter was noted and compared to measurements obtained by the reference scan (CT scan or vascular sonographer-performed ultrasound). Reference scans were completed within 3 months of the recruitment visit. A total of 57 patients were enrolled over a 5-month period between October 2015 and March 2016. Mean age of recruited patients was 71 years and 61% were male. Mean body mass index was 27.9 ± 4.3 and mean waist-hip ratio was 0.96 ± 0.10. Sixteen abdominal aortic aneurysms were detected by the reference scan, with an average maximal aortic diameter of 44.9 mm. Physical examination by a vascular surgeon detected 11 of 16 abdominal aortic aneurysms with 2 false positives (sensitivity and specificity of 66.7% (95% CI 38.4-88.2) and 94.4% (95% CI 81.3-99.3), respectively). Point-of-care ultrasound detected 15 of 16 abdominal aortic aneurysms (sensitivity and specificity of 93.3% (95% CI 68.1-99.8) and 100% (95% CI 88.4-100), respectively). Seven of the 64 point-of-care ultrasound scans were indeterminate (>1 cm of the aorta was not visualized). Average time to conduct the physical examination was 35 seconds vs. 4.0 minutes for point-of-care ultrasonography. There was a
Office-based ultrasound screening for abdominal aortic aneurysm
Blois, Beau
2012-01-01
Abstract Objective To assess the efficacy of an office-based, family physician–administered ultrasound examination to screen for abdominal aortic aneurysm (AAA). Design A prospective observational study. Consecutive patients were approached by nonphysician staff. Setting Rural family physician offices in Grand Forks and Revelstoke, BC. Participants The Canadian Society for Vascular Surgery screening recommendations for AAA were used to help select patients who were at risk of AAA. All men 65 years of age or older were included. Women 65 years of age or older were included if they were current smokers or had diabetes, hypertension, a history of coronary artery disease, or a family history of AAA. Main outcome measures A focused “quick screen,” which measured the maximal diameter of the abdominal aorta using point-of-care ultrasound technology, was performed in the office by a resident physician trained in emergency ultrasonography. Each patient was then booked for a criterion standard scan (ie, a conventional abdominal ultrasound scan performed by a technician and interpreted by a radiologist). The maximal abdominal aortic diameter measured by ultrasound in the office was compared with that measured by the criterion standard method. The time to screen each patient was recorded. Results Forty-five patients were included in data analysis; 62% of participants were men. The mean age was 73 years. The mean pairwise difference between the office-based ultrasound scan and the criterion standard scan was not statistically significant. The mean absolute difference between the 2 scans was 0.20 cm (95% CI 0.15 to 0.25 cm). Correlation between the scans was 0.81. The office-based ultrasound scan had both a sensitivity and a specificity of 100%. The mean time to screen each patient was 212 seconds (95% CI 194 to 230 seconds). Conclusion Abdominal aortic aneurysm screening can be safely performed in the office by family physicians who are trained to use point
Office-based ultrasound screening for abdominal aortic aneurysm.
Blois, Beau
2012-03-01
To assess the efficacy of an office-based, family physician–administered ultrasound examination to screen for abdominal aortic aneurysm (AAA). A prospective observational study. Consecutive patients were approached by nonphysician staff. Rural family physician offices in Grand Forks and Revelstoke, BC. The Canadian Society for Vascular Surgery screening recommendations for AAA were used to help select patients who were at risk of AAA. All men 65 years of age or older were included. Women 65 years of age or older were included if they were current smokers or had diabetes, hypertension, a history of coronary artery disease, or a family history of AAA. A focused “quick screen”, which measured the maximal diameter of the abdominal aorta using point-of-care ultrasound technology, was performed in the office by a resident physician trained in emergency ultrasonography. Each patient was then booked for a criterion standard scan (i.e., a conventional abdominal ultrasound scan performed by a technician and interpreted by a radiologist). The maximal abdominal aortic diameter measured by ultrasound in the office was compared with that measured by the criterion standard method. The time to screen each patient was recorded. Forty-five patients were included in data analysis; 62% of participants were men. The mean age was 73 years. The mean pairwise difference between the office-based ultrasound scan and the criterion standard scan was not statistically significant. The mean absolute difference between the 2 scans was 0.20 cm (95% CI 0.15 to 0.25 cm). Correlation between the scans was 0.81. The office-based ultrasound scan had both a sensitivity and a specificity of 100%. The mean time to screen each patient was 212 seconds (95% CI 194 to 230 seconds). Abdominal aortic aneurysm screening can be safely performed in the office by family physicians who are trained to use point-of- care ultrasound technology. The screening test can be completed within the time constraints of a
Reproducibility of abdominal fat assessment by ultrasound and computed tomography.
Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge
2017-01-01
To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility.
Emergency ultrasound-based algorithms for diagnosing blunt abdominal trauma.
Stengel, Dirk; Bauwens, Kai; Rademacher, Grit; Ekkernkamp, Axel; Güthoff, Claas
2013-07-31
Ultrasonography is regarded as the tool of choice for early diagnostic investigations in patients with suspected blunt abdominal trauma. Although its sensitivity is too low for definite exclusion of abdominal organ injury, proponents of ultrasound argue that ultrasound-based clinical pathways enhance the speed of primary trauma assessment, reduce the number of computed tomography scans and cut costs. To assess the effects of trauma algorithms that include ultrasound examinations in patients with suspected blunt abdominal trauma. We searched the Cochrane Injuries Group's Specialised Register, CENTRAL (The Cochrane Library), MEDLINE (OvidSP), EMBASE (OvidSP), CINAHL (EBSCO), publishers' databases, controlled trials registers and the Internet. Bibliographies of identified articles and conference abstracts were searched for further elligible studies. Trial authors were contacted for further information and individual patient data. The searches were updated in February 2013. randomised controlled trials (RCTs) and quasi-randomised trials (qRCTs). patients with blunt torso, abdominal or multiple trauma undergoing diagnostic investigations for abdominal organ injury. diagnostic algorithms comprising emergency ultrasonography (US). diagnostic algorithms without ultrasound examinations (for example, primary computed tomography [CT] or diagnostic peritoneal lavage [DPL]). mortality, use of CT and DPL, cost-effectiveness, laparotomy and negative laparotomy rates, delayed diagnoses, and quality of life. Two authors independently selected trials for inclusion, assessed methodological quality and extracted data. Where possible, data were pooled and relative risks (RRs), risk differences (RDs) and weighted mean differences, each with 95% confidence intervals (CIs), were calculated by fixed- or random-effects modelling, as appropriate. We identified four studies meeting our inclusion criteria. Overall, trials were of moderate methodological quality. Few trial authors responded to
Reproducibility of abdominal fat assessment by ultrasound and computed tomography
Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge
2017-01-01
Objective: To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Materials and Methods: Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Results: Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. Conclusion: In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility. PMID:28670024
Kanakarajan, Saravanakumar; High, Kristina; Nagaraja, Ravi
2011-03-01
Chronic abdominal wall pain occurs in about 10-30% of patients presenting with chronic abdominal pain. Entrapment of abdominal cutaneous nerves at the lateral border of the rectus abdominis muscle has been attributed as a cause of abdominal wall pain. We report our experience of treating such patients using ultrasound-guided abdominal cutaneous nerve infiltration. We conducted a retrospective audit of abdominal cutaneous nerve infiltration performed in the period between September 2008 to August 2009 in our center. All patients had received local anesthetic and steroid injection under ultrasound guidance. The response to the infiltration was evaluated in the post-procedure telephone review as well as in the follow-up clinic. Brief pain inventory (BPI) and numerical rating scale pain scores were collated from two points: the initial outpatient clinic and the follow up clinic up to 5 months following the injection. Nine patients had abdominal cutaneous nerve injections under ultrasound guidance in the period under review. Six patients reported 50% pain relief or more (responders) while three patients did not. Pain and BPI scores showed a decreasing trend in responders. The median duration of follow-up was 12 weeks. Ultrasound can reliably be used for infiltration of the abdominal cutaneous nerves. This will improve the safety as well as diagnostic utility of the procedure. Wiley Periodicals, Inc.
Basic Abdominal Point-of-Care Ultrasound Training in the Undergraduate: Students as Mentors.
Garcia-Casasola, Gonzalo; Sánchez, Francisco Javier García; Luordo, Davide; Zapata, Deborah Forrester; Frías, María Carnevali; Garrido, Victoria Villena; Martínez, Javier Villanueva; de la Sotilla, Alberto Forero; Rojo, José Manuel Casas; Macho, Juan Torres
2016-11-01
To analyze the ability of medical students to be integrated in the teaching of basic abdominal ultrasound using a peer-mentoring design. Thirty medical students previously trained in basic abdominal ultrasound (mentors) had to teach all fourth-year students (n = 136) from a single academic year the same training they had received. There were 3 stages to the ultrasound teaching: theoretical (online course); basic training (3 practical sessions in which students were guaranteed to have had a minimum of 15 hours of practical experience with ultrasound and performed at least 20 basic abdominal ultrasound studies); and evaluation (objective structured clinical examination in which students had to obtain the basic abdominal views and to identify 17 structures). The mean grade ± SD obtained was 8.71 ± 1.53 of a possible 10 points. Only 2 students (1.56%) obtained a grade lower than 5, and 14 students (10.86%) obtained a grade lower than 7. A total of 33 students (25.5%) achieved the maximum grade. The structures most easily identified were the liver, the right kidney, and the urinary bladder, with 97.7% of correct answers. Students obtained the poorest results when trying to identify the left and right cardiac cavities (subxiphoid view), with only 53.5% and 55.8% of correct answers, respectively. Teaching based on peer mentoring achieved an adequate level of training in basic abdominal ultrasound. The students acquired these skills in a relatively short training period. These results suggest that peer mentoring can facilitate the large-scale implementation of ultrasound teaching in undergraduate students. © 2016 by the American Institute of Ultrasound in Medicine.
Successful Treatment of Abdominal Cutaneous Entrapment Syndrome Using Ultrasound Guided Injection
Hong, Myong Joo; Seo, Dong Hyuk
2013-01-01
There are various origins for chronic abdominal pain. About 10-30% of patients with chronic abdominal pain have abdominal wall pain. Unfortunately, abdominal wall pain is not thought to be the first origin of chronic abdominal pain; therefore, patients usually undergo extensive examinations, including diagnostic laparoscopic surgery. Entrapment of abdominal cutaneous nerves at the muscular foramen of the rectus abdominis is a rare cause of abdominal wall pain. If abdominal wall pain is considered in earlier stage of chronic abdominal pain, unnecessary invasive procedures are not required and patients will reach symptom free condition as soon as the diagnosis is made. Here, we report a case of successful treatment of a patient with abdominal cutaneous nerve entrapment syndrome by ultrasound guided injection therapy. PMID:23862004
Sonhaye, L; Tchaou, M; Amadou, A; Gbande, P; Assih, K; Djibril, M; Adjenou, K; Redah, D; N'Dakéna, K
2014-01-01
Few studies have examined ultrasound imaging of abdominal manifestations of HIV-AIDS, although these rank second only to its pleuropulmonary manifestations. Thus, this study sought to determine the features of abdominal ultrasound in HIV infection. This prospective, descriptive and analytical study took place in the radiology department of the University Hospital Campus Lomé and covered the three-year period of 2009-2011. It included all patients older than 15 years with positive HIV serology. During the study period, 566 patients met the inclusion criteria. Ultrasound examination showed the liver appeared normal in 153 patients (27.0%), but homogeneously hyperechoic and thus suggestive of hepatic steatosis in 107 (18.9%). The bile duct was dilatated in 12 patients or 2.1%. An anomaly in the corticomedullary differentiation in normal-sized kidneys was noted in 28.1% (159 patients). Diffuse homogeneous hypertrophy of the pancreas was found in 3 patients (0.53%). Splenomegaly was noted in 387 patients (68.4%); the echopattern of the spleen was diffusely micronodular in 6 patients (1.1%). Deep adenopathies were found in 29 patients (5.1%) and ascites in 46 patients (8.1%). Abdominal ultrasound is a medical imaging technique available in developing countries, less expensive than others, which can be considered an alternative to computed tomography (CT) in the countries of sub-Saharan Africa for the exploration of the abdominal manifestations of HIV.
The role of abdominal ultrasound in the diagnosis of typhoid fever: an observational study.
Younis, Saeed Nadhim
2014-01-01
To study the usefulness of abdominal ultrasound in the diagnosis of typhoid fever and to determine the common ultrasound findings early in the course of the disease. Abdominal ultrasound examination was performed within the first week of initiation of symptoms in 350 cases with clinical diagnosis of typhoid fever. Subsequent ultrasound follow-up examination was done 15 days later (beginning of the third week). All the patients proved to have positive Widal test and Sallmonella culture. The study was performed in Erbil-Iraq from the period January 1993 to October 2010. The following ultrasound findings were reported: hepatomegaly (31.4%), prominent intrahepatic bile ducts (64.85%), splenomegaly (100%), mesenteric lymphadenopathy (42.85%), bowel wall thickening (35.71%), acalculous cholecystitis (16.28%), perforations (1.14%), and ascites in (3.4%). The current study showed that the findings are typical enough to justify initiation of treatment for typhoid fever when serology is equivocal and culture is negative, and is fairly safe to say that normal ultrasound examination early in the course of febrile illness rules out typhoid fever. Copyright © 2013 Elsevier Ltd. All rights reserved.
[Ultrasound-guided rectus sheath block for upper abdominal surgery].
Osaka, Yoshimune; Kashiwagi, Masanori; Nagatsuka, Yukio; Oosaku, Masayoshi; Hirose, Chikako
2010-08-01
Upper abdominal surgery leads to severe postoperative pain. Insufficient postoperative analgesia accompanies a high incidence of complications. Therefore, postoperative analgesia is very important. The epidural analgesia has many advantages. However it has a high risk of epidural hematoma in anticoagulated patients. Rectus sheath block provided safer and more reliable analgesia in recent years, by the development of ultrasound tools. We experienced two cases of the rectus sheath block in upper abdominal surgery under ultrasound guidance. Ultrasound guided rectus sheath block can reduce the risk of peritoneal puncture, bleeding, and other complications. Rectus sheath block is very effective to reduce postoperative pain in upper abdominal surgery as an alternative method to epidural anesthesia in anticoagulated patients.
Radiographer-performed abdominal and pelvic ultrasound: its value in a urology out-patient clinic.
Nargund, V H; Lomas, K; Sapherson, D A; Flannigan, G M; Stewart, P A
1994-04-01
To assess the efficacy of radiographer-performed ultrasound examination as a routine investigative procedure in a urological out-patient clinic. A total of 151 patients attending a District General Hospital Urological Out-patient Department underwent an ultrasound examination in the clinic. Diagnosis by ultrasound was achieved in 93% of patients. The remaining patients underwent further investigations. Two (1%) patients with normal scans had small bladder tumours. Subsequent intravenous urography in these individuals showed normal upper tracts. Abdominal and pelvic ultrasound examination performed in the urological out-patient clinic on unprepared patients was the only investigation necessary for evaluation of common problems such as non-specific urinary symptoms, recurrent urinary tract infections and bladder outlet obstruction.
Poulsen, Liv la Cour; Bækgaard, Emilie Stokholm; Istre, Per Grosen; Schmidt, Thomas Andersen; Larsen, Torben
2015-01-01
Purpose Ultrasonography is a noninvasive, cheap, and fast way of assessing abdominal pain in an emergency department. Many physicians working in emergency departments do not have pre-existing ultrasound experience. The purpose of this study was to investigate the ability of first-year internship doctors to perform a reliable ultrasound examination on patients with abdominal pain in an emergency setting. Materials and methods This study took place in an emergency department in Denmark. Following a 1-day ultrasound introduction course, three doctors without prior ultrasound experience scanned 45 patients during a 2-month period. The applicability of the examinations was evaluated by subsequent control examination: computed tomography, operation, or ultrasound by a trained radiologist or gynecologist or, in cases where the patient was immediately discharged, by ultrasound image evaluation. Results In 14 out of 21 patients with a control examination, there was diagnostic agreement between the project ultrasound examination and the control. Image evaluation of all patients showed useful images of the gallbladder, kidneys, liver, abdominal aorta, and urinary bladder, but no useful images for either the pancreas or colon. Conclusion With only little formal training, it is possible for first-year internship doctors to correctly visualize some abdominal organs with ultrasonography. However, a longer study time frame, including more patients, and an ultrasound course specifically designed for the purpose of use in an emergency department, is needed to enhance the results. PMID:27147884
Zhu, Dan; Gu, Zhi-Yong; Lin, Chia-Shiang; Nie, Fa-Chuan; Cui, Jian
2018-04-01
Abdominal pain and hiccups secondary to intra-abdominal adhesion are surgical complications that are often treated by painkillers and secondary surgeries with an unsatisfactory therapeutic effect. This study presents a new treatment method that uses ultrasound-guided local infiltration in peritoneal and abdominal wall adhesions in patients with hiccups and abdominal pain. A 62-year-old patient presented to our hospital with a history of intractable hiccups and abdominal pain for 30 years. Her abdominal examination revealed a scar with an approximate length of 10 cm on the abdominal umbilical plane; pressing the right scar area could simultaneously induce abdominal pain and hiccups. Intraperitoneal computed tomography examination clearly demonstrated that the bowel had no obvious expansion. Ultrasonographic examination found that peritoneal motility below the normal peritoneal adhesion regions was significantly slower than in the normal regions. The diagnosis of chronic postoperative pain syndrome was clear. The symptoms were significantly alleviated by a successful treatment with ultrasound-guided local infiltration in the peritoneal and abdominal wall scar adhesions. After 3 stages of hospitalization and 1 year of follow-up, the patient's abdominal wall pain was relieved by approximately 80% and hiccups were relieved by approximately 70%. The above treatment is a useful option for managing abdominal adhesion and accompanying pain or hiccups resulting from abdominal surgery. This method could ease the psychological and economic burden of patients and improve their quality of life.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 2 2014-10-01 2014-10-01 false Ultrasound screening for abdominal aortic aneurysms... (SMI) BENEFITS Medical and Other Health Services § 410.19 Ultrasound screening for abdominal aortic... ultrasound screening for an abdominal aortic aneurysm under Medicare program; and (2) Is included in at least...
Pocket-sized versus standard ultrasound machines in abdominal imaging.
Tse, K H; Luk, W H; Lam, M C
2014-06-01
The pocket-sized ultrasound machine has emerged as an invaluable tool for quick assessment in emergency and general practice settings. It is suitable for instant and quick assessment in cardiac imaging. However, its applicability in the imaging of other body parts has yet to be established. In this pictorial review, we compared the performance of the pocketsized ultrasound machine against the standard ultrasound machine for its image quality in common abdominal pathology.
Strain measurement of abdominal aortic aneurysm with real-time 3D ultrasound speckle tracking.
Bihari, P; Shelke, A; Nwe, T H; Mularczyk, M; Nelson, K; Schmandra, T; Knez, P; Schmitz-Rixen, T
2013-04-01
Abdominal aortic aneurysm rupture is caused by mechanical vascular tissue failure. Although mechanical properties within the aneurysm vary, currently available ultrasound methods assess only one cross-sectional segment of the aorta. This study aims to establish real-time 3-dimensional (3D) speckle tracking ultrasound to explore local displacement and strain parameters of the whole abdominal aortic aneurysm. Validation was performed on a silicone aneurysm model, perfused in a pulsatile artificial circulatory system. Wall motion of the silicone model was measured simultaneously with a commercial real-time 3D speckle tracking ultrasound system and either with laser-scan micrometry or with video photogrammetry. After validation, 3D ultrasound data were collected from abdominal aortic aneurysms of five patients and displacement and strain parameters were analysed. Displacement parameters measured in vitro by 3D ultrasound and laser scan micrometer or video analysis were significantly correlated at pulse pressures between 40 and 80 mmHg. Strong local differences in displacement and strain were identified within the aortic aneurysms of patients. Local wall strain of the whole abdominal aortic aneurysm can be analysed in vivo with real-time 3D ultrasound speckle tracking imaging, offering the prospect of individual non-invasive rupture risk analysis of abdominal aortic aneurysms. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 2 2012-10-01 2012-10-01 false Ultrasound screening for abdominal aortic aneurysms... (SMI) BENEFITS Medical and Other Health Services § 410.19 Ultrasound screening for abdominal aortic... definitions apply: Eligible beneficiary means an individual who— (1) Has received a referral for an ultrasound...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 2 2013-10-01 2013-10-01 false Ultrasound screening for abdominal aortic aneurysms... (SMI) BENEFITS Medical and Other Health Services § 410.19 Ultrasound screening for abdominal aortic... definitions apply: Eligible beneficiary means an individual who— (1) Has received a referral for an ultrasound...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 2 2011-10-01 2011-10-01 false Ultrasound screening for abdominal aortic aneurysms... (SMI) BENEFITS Medical and Other Health Services § 410.19 Ultrasound screening for abdominal aortic... definitions apply: Eligible beneficiary means an individual who— (1) Has received a referral for an ultrasound...
Tyloch, Janusz F; Woźniak, Magdalena Maria; Wieczorek, Andrzej Paweł
2013-09-01
The paper presents the principles of performing proper ultrasound examinations of the urinary tract. The following are discussed: preparation of patients, type of optimal apparatus, technique of examination and conditions which its description should fulfill. Urinary track examination in adults and in children constitutes an integral part of each abdominal examination. Such examinations should be performed with fasting patients or several hours after the last meal, with filled urinary bladder. Ultrasound examinations in children and infants are performed using transducers with the frequency of 5.0-9.0 MHz and in adults - with the frequency of 2.0-6.0 MHz. Doppler options are desirable since they improve diagnostic capacity of sonography in terms of differentiation between renal focal lesions. Renal examinations are performed with the patients in the supine position. The right kidney is examined in the right hypochondriac region using the liver as the ultrasound "window." The left kidney is examined in the left hypochondriac region, preferably in the posterior axillary line. Ultrasound examinations of the upper segment of the ureters are performed after renal examination when the pelvicalyceal system is dilated. A condition necessary for a proper examination of the perivesical portion of the ureter is full urinary bladder. The scans of the urinary bladder are performed in transverse, longitudinal and oblique planes when the bladder is filled. The description should include patient's personal details, details of the referring unit, of the unit in which the examination is performed, examining physician's details, type of ultrasound apparatus and transducers as well as the description proper.
Patel, Pankaj A; Ernst, Frank R; Gunnarsson, Candace L
2012-01-01
Abdominal paracentesis is commonly performed for diagnostic, therapeutic, and palliative indications, but the use of ultrasound guidance for these procedures is relatively recent, variable, and not well documented. A retrospective database analysis of abdominal paracentesis procedures was performed to determine whether ultrasound guidance was associated with differences in adverse events (AEs) or hospital costs, compared to procedures without ultrasound guidance. The hospital database maintained by Premier was used to identify patients with abdominal paracentesis International Classification of Diseases - 9th Revision - Clinical Modification (ICD-9 code 54.9, Common Procedural Terminology CPT-4 codes 49080, 49081) in 2008. Use of ultrasound guidance was determined via patient billing data. The incidence of selected AEs and patients' hospitalization costs were calculated for two groups: procedures with ultrasound guidance and those without. Univariate and multivariable analyses were performed to evaluate differences between groups. This study identified 1297 abdominal paracentesis procedures, 723 (56%) with ultrasound and 574 (44%) without. The indications for paracentesis were similar between the two groups. The incidence of AEs was lower in ultrasound-guided procedures: all AEs (1.4% vs 4.7%, p = 0.01), post-paracentesis infection (0.41% vs 2.44%, p = 0.01), hematoma (0.0% vs 0.87%, p = 0.01), and seroma (0.14% vs 1.05%, p = 0.03). Analyses adjusted for patient and hospital covariates revealed significant reductions in AEs (OR = 0.349, 95% CI = 0.165, 0.739, p = 0.0059) and hospitalization costs ($8761 ± $5956 vs $9848 ± $6581, p < 0.001) for procedures with ultrasound guidance vs those without. There are several limitations to using claims data for clinical analyses; causality cannot be determined, the possibility of miscoded or missing data, and the inability to control for elements not captured in claims data that may
Palladino, S; Keyerleber, M A; King, R G; Burgess, K E
2016-11-01
Apocrine gland adenocarcinoma of the anal sac (AGAAS) is associated with high rates of iliosacral lymph node metastasis, which may influence treatment and prognosis. Magnetic resonance imaging (MRI) recently has been shown to be more sensitive than abdominal ultrasound examination (AUS) in affected patients. To compare the rate of detection of iliosacral lymphadenomegaly between AUS and computed tomography (CT) in dogs with AGAAS. Cohort A: A total of 30 presumed normal dogs. Cohort B: A total of 20 dogs with AGAAS that underwent AUS and CT. Using cohort A, mean normalized lymph node : aorta (LN : AO) ratios were established for medial iliac, internal iliac, and sacral lymph nodes. The CT images in cohort B then were reviewed retrospectively and considered enlarged if their LN : AO ratio measured 2 standard deviations above the mean normalized ratio for that particular node in cohort A. Classification and visibility of lymph nodes identified on AUS were compared to corresponding measurements obtained on CT. Computed tomography identified lymphadenomegaly in 13 of 20 AGAAS dogs. Of these 13 dogs, AUS correctly identified and detected all enlarged nodes in only 30.8%, and either misidentified or failed to detect additional enlarged nodes in the remaining dogs. Despite limitations in identifying enlargement in all affected lymph nodes, AUS identified at least 1 enlarged node in 100% of affected dogs. Abdominal ultrasound examination is an effective screening test for lymphadenomegaly in dogs with AGAAS, but CT should be considered in any patient in which an additional metastatic site would impact therapeutic planning. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Contrast-enhanced ultrasound (CEUS) in blunt abdominal trauma
Piccolo, Claudia Lucia; Galluzzo, Michele; Ianniello, Stefania; Sessa, Barbara; Trinci, Margherita
2016-01-01
Baseline ultrasound is essential in the early assessment of patients with a huge haemoperitoneum undergoing an immediate abdominal surgery; nevertheless, even with a highly experienced operator, it is not sufficient to exclude parenchymal injuries. More recently, a new ultrasound technique using second generation contrast agents, named contrast-enhanced ultrasound (CEUS) has been developed. This technique allows all the vascular phase to be performed in real time, increasing ultrasound capability to detect parenchymal injuries, enhancing some qualitative findings, such as lesion extension, margins and its relationship with capsule and vessels. CEUS has been demonstrated to be almost as sensitive as contrast-enhanced CT in the detection of traumatic injuries in patients with low-energy isolated abdominal trauma, with levels of sensitivity and specificity up to 95%. Several studies demonstrated its ability to detect lesions occurring in the liver, spleen, pancreas and kidneys and also to recognize active bleeding as hyperechoic bands appearing as round or oval spots of variable size. Its role seems to be really relevant in paediatric patients, thus avoiding a routine exposure to ionizing radiation. Nevertheless, CEUS is strongly operator dependent, and it has some limitations, such as the cost of contrast media, lack of panoramicity, the difficulty to explore some deep regions and the poor ability to detect injuries to the urinary tract. On the other hand, it is timesaving, and it has several advantages, such as its portability, the safety of contrast agent, the lack to ionizing radiation exposure and therefore its repeatability, which allows follow-up of those traumas managed conservatively, especially in cases of fertile females and paediatric patients. PMID:26607647
Shin, Junseob; Chen, Yu; Malhi, Harshawn; Chen, Frank; Yen, Jesse
2018-05-01
Degradation of image contrast caused by phase aberration, off-axis clutter, and reverberation clutter remains one of the most important problems in abdominal ultrasound imaging. Multiphase apodization with cross-correlation (MPAX) is a novel beamforming technique that enhances ultrasound image contrast by adaptively suppressing unwanted acoustic clutter. MPAX employs multiple pairs of complementary sinusoidal phase apodizations to intentionally introduce grating lobes that can be used to derive a weighting matrix, which mostly preserves the on-axis signals from tissue but reduces acoustic clutter contributions when multiplied with the beamformed radio-frequency (RF) signals. In this paper, in vivo performance of the MPAX technique was evaluated in abdominal ultrasound using data sets obtained from 10 human subjects referred for abdominal ultrasound at the USC Keck School of Medicine. Improvement in image contrast was quantified, first, by the contrast-to-noise ratio (CNR) and, second, by the rating of two experienced radiologists. The MPAX technique was evaluated for longitudinal and transverse views of the abdominal aorta, the inferior vena cava, the gallbladder, and the portal vein. Our in vivo results and analyses demonstrate the feasibility of the MPAX technique in enhancing image contrast in abdominal ultrasound and show potential for creating high contrast ultrasound images with improved target detectability and diagnostic confidence.
Cheng, Phillip M; Malhi, Harshawn S
2017-04-01
The purpose of this study is to evaluate transfer learning with deep convolutional neural networks for the classification of abdominal ultrasound images. Grayscale images from 185 consecutive clinical abdominal ultrasound studies were categorized into 11 categories based on the text annotation specified by the technologist for the image. Cropped images were rescaled to 256 × 256 resolution and randomized, with 4094 images from 136 studies constituting the training set, and 1423 images from 49 studies constituting the test set. The fully connected layers of two convolutional neural networks based on CaffeNet and VGGNet, previously trained on the 2012 Large Scale Visual Recognition Challenge data set, were retrained on the training set. Weights in the convolutional layers of each network were frozen to serve as fixed feature extractors. Accuracy on the test set was evaluated for each network. A radiologist experienced in abdominal ultrasound also independently classified the images in the test set into the same 11 categories. The CaffeNet network classified 77.3% of the test set images accurately (1100/1423 images), with a top-2 accuracy of 90.4% (1287/1423 images). The larger VGGNet network classified 77.9% of the test set accurately (1109/1423 images), with a top-2 accuracy of VGGNet was 89.7% (1276/1423 images). The radiologist classified 71.7% of the test set images correctly (1020/1423 images). The differences in classification accuracies between both neural networks and the radiologist were statistically significant (p < 0.001). The results demonstrate that transfer learning with convolutional neural networks may be used to construct effective classifiers for abdominal ultrasound images.
Real-time correction of beamforming time delay errors in abdominal ultrasound imaging
NASA Astrophysics Data System (ADS)
Rigby, K. W.
2000-04-01
The speed of sound varies with tissue type, yet commercial ultrasound imagers assume a constant sound speed. Sound speed variation in abdominal fat and muscle layers is widely believed to be largely responsible for poor contrast and resolution in some patients. The simplest model of the abdominal wall assumes that it adds a spatially varying time delay to the ultrasound wavefront. The adequacy of this model is controversial. We describe an adaptive imaging system consisting of a GE LOGIQ 700 imager connected to a multi- processor computer. Arrival time errors for each beamforming channel, estimated by correlating each channel signal with the beamsummed signal, are used to correct the imager's beamforming time delays at the acoustic frame rate. A multi- row transducer provides two-dimensional sampling of arrival time errors. We observe significant improvement in abdominal images of healthy male volunteers: increased contrast of blood vessels, increased visibility of the renal capsule, and increased brightness of the liver.
Estimation of prenatal aorta intima-media thickness from ultrasound examination
NASA Astrophysics Data System (ADS)
Veronese, E.; Tarroni, G.; Visentin, S.; Cosmi, E.; Linguraru, M. G.; Grisan, E.
2014-10-01
Prenatal events such as intrauterine growth restriction and increased cardiovascular risk in later life have been shown to be associated with an increased intima-media thickness (aIMT) of the abdominal aorta in the fetus. In order to assess and manage atherosclerosis and cardiovascular disease risk in adults and children, in recent years the measurement of abdominal and carotid artery thickness has gained a growing appeal. Nevertheless, no computer aided method has been proposed for the analysis of prenatal vessels from ultrasound data, yet. To date, these measurements are being performed manually on ultrasound fetal images by skilled practitioners. The aim of the presented study is to introduce an automatic algorithm that identifies abdominal aorta and estimates its diameter and aIMT from routine third trimester ultrasonographic fetal data. The algorithm locates the aorta, then segments it and, by modeling the arterial wall longitudinal sections by means of a gaussian mixture, derives a set of measures of the aorta diameter (aDiam) and of the intima-media thickness (aIMT). After estimating the cardiac cycle, the mean diameter and the aIMT at the end-diastole phase are computed. Considering the aIMT value for each subject, the correlation between automatic and manual end-diastolic aIMT measurements is 0.91 in a range of values 0.44-1.10 mm, corresponding to both normal and pathological conditions. The automatic system yields a mean relative error of 19%, that is similar to the intra-observer variability (14%) and much lower that the inter-observer variability (42%). The correlation between manual and automatic measurements and the small error confirm the ability of the proposed system to reliably estimate aIMT values in prenatal ultrasound sequences, reducing measurement variability and suggesting that it can be used for an automatic assessment of aIMT. Preliminary results have been presented in E Veronese, E Cosmi, S Visentin, E Grisan: 'Semiautomatic estimation
Vasseljen, Ottar; Fladmark, Anne M; Westad, Christian; Torp, Hans G
2009-04-01
Delayed onset of muscle activity in abdominal muscles has been related to low back pain. To investigate this in larger clinical trials it would be beneficial if non-invasive and less cumbersome alternatives to intramuscular electromyography (EMG) were available. This study was designed to compare onset of muscle activity recorded by intramuscular EMG to onset of muscle deformations by ultrasound imaging. Muscle deformations were recorded by two ultrasound imaging modes at high time resolution (m-mode and tissue velocity) in separate sessions and compared to simultaneously recorded intramuscular EMG in three abdominal muscles. Tissue velocity imaging was converted to strain rate which measures deformation velocity gradients within small regions, giving information about the rate of local tissue shortening or lengthening along the beam axis. Onsets in transversus abdominis (TrA), obliquus internus abdominis (OI) and obliquus externus abdominis (OE) were recorded during rapid arm flexions in ten healthy subjects. During ultrasound m-mode recordings, the results showed that mean onsets by EMG were detected 7 ms (95% CI of mean difference; +/-4 ms) and 2 ms (95% CI of mean difference; +/-6 ms) before concurrent ultrasound m-mode detected onsets in TrA and OI, respectively. In contrast, OE onset was recorded 54 ms (95% CI of bias; +/-16 ms) later by EMG compared to ultrasound m-mode. The discrepancy of ultrasound m-mode to accurately record onset in OE was practically corrected in the ultrasound-based strain rate recordings. However, this could only be applied on half of the subjects due to the angle dependency between the ultrasound beam and the direction of the contraction in strain rate recordings. The angle dependency needs to be further explored.
Østergaard, Mia L; Nielsen, Kristina R; Albrecht-Beste, Elisabeth; Konge, Lars; Nielsen, Michael B
2018-01-01
This study aimed to develop a test with validity evidence for abdominal diagnostic ultrasound with a pass/fail-standard to facilitate mastery learning. The simulator had 150 real-life patient abdominal scans of which 15 cases with 44 findings were selected, representing level 1 from The European Federation of Societies for Ultrasound in Medicine and Biology. Four groups of experience levels were constructed: Novices (medical students), trainees (first-year radiology residents), intermediates (third- to fourth-year radiology residents) and advanced (physicians with ultrasound fellowship). Participants were tested in a standardized setup and scored by two blinded reviewers prior to an item analysis. The item analysis excluded 14 diagnoses. Both internal consistency (Cronbach's alpha 0.96) and inter-rater reliability (0.99) were good and there were statistically significant differences (p < 0.001) between all four groups, except the intermediate and advanced groups (p = 1.0). There was a statistically significant correlation between experience and test scores (Pearson's r = 0.82, p < 0.001). The pass/fail-standard failed all novices (no false positives) and passed all advanced (no false negatives). All intermediate participants and six out of 14 trainees passed. We developed a test for diagnostic abdominal ultrasound with solid validity evidence and a pass/fail-standard without any false-positive or false-negative scores. • Ultrasound training can benefit from competency-based education based on reliable tests. • This simulation-based test can differentiate between competency levels of ultrasound examiners. • This test is suitable for competency-based education, e.g. mastery learning. • We provide a pass/fail standard without false-negative or false-positive scores.
Linek, Pawel; Saulicz, Edward; Wolny, Tomasz; Myśliwiec, Andrzej
2017-04-01
The purpose of this study was to determine the value of the allometric parameter for ultrasound measurements of the thickness of the oblique external (OE), internal (OI), and transversus abdominis (TrA) muscles in the adolescent population. The allometric parameter is the slope of the linear regression line between the log transformed body mass and log transformed muscle size measurement. The study included 321 adolescents between the ages of 10 and 17, consisting of 160 boys and 161 girls. The participants were recruited from local schools and attended regular school classes at normal grade levels. All individuals with no signs of scoliosis (screening with use of a scoliometer), and no surgical procedures performed on the trunk area were included. A real-time ultrasound B-scanner with a linear array transducer was used to obtain images of the lateral abdominal muscles from both sides of the body. The correlation between body mass and the OE muscle was r = 0.69; the OI muscle r = 0.68; and the TrA muscle r = 0.53 (in all cases, P < .0001). The allometric parameter for the OE was 0.88296; the OI 0.718756; and the TrA 0.60986. Using these parameters, no significant correlations were found between body mass and the allometric-scaled thickness of the lateral abdominal muscles. Significant positive correlations exist between body mass and lateral abdominal muscle thickness assessed by ultrasound imaging. Therefore, it is reasonable to advise that the values of the allometric parameters for OE, OI, and TrA obtained in this study should be used in other studies performed on adolescents. © 2016 by the American Institute of Ultrasound in Medicine.
Dinh, Vi Am; Frederick, Jon; Bartos, Rebekah; Shankel, Tamara M; Werner, Leonard
2015-01-01
Increasing emphasis has been placed on point-of-care ultrasound in medical school. The overall effects of ultrasound curriculum implementation on the traditional physical examination skills of medical students are still unknown. We studied the effects on the Objective Standardized Clinical Examination (OSCE) scores of year 1 medical students before and after ultrasound curriculum implementation. An ultrasound curriculum was incorporated into the physical diagnosis course for year 1 medical students in the 2012-2013 academic year. We performed a prospective observational study comparing traditional OSCE scores of year 1 medical students exposed to the ultrasound curriculum (post-ultrasound) versus historic year 1 medical student controls (pre-ultrasound) with no ultrasound exposure. Questionnaire data were also obtained from year 1 medical students and physical diagnosis faculty to assess attitudes toward ultrasound implementation. The final overall OSCE scores were graded with a 5-point Likert-type scale from unsatisfactory to outstanding. There was a significant increase in outstanding scores in the post-ultrasound compared to the pre-ultrasound group (27.0% versus 10.9%; P< .001). The post-ultrasound group had significantly (P< .05) increased first-time pass rates on blood pressure measurements, the abdominal examination, and professionalism. Student and physical diagnosis faculty questionnaire data showed an overall positive response, with most agreeing or strongly agreeing that ultrasound should be included in the future year 1 medical student curriculum. Ultrasound implementation into a physical diagnosis curriculum for year 1 medical students is feasible and may improve their overall traditional physical examination skills. © 2015 by the American Institute of Ultrasound in Medicine.
Abdominal aortic aneurysm screening program using hand-held ultrasound in primary healthcare
Kostov, Belchin; Navarro González, Marta; Cararach Salami, Daniel; Pérez Jiménez, Alfonso; Gilabert Solé, Rosa; Bru Saumell, Concepció; Donoso Bach, Lluís; Villalta Martí, Mireia; González-de Paz, Luis; Ruiz Riera, Rafael; Riambau Alonso, Vicenç; Acar-Denizli, Nihan; Farré Almacellas, Marta; Ramos-Casals, Manuel; Benavent Àreu, Jaume
2017-01-01
We determined the feasibility of abdominal aortic aneurysm (AAA) screening program led by family physicians in public primary healthcare setting using hand-held ultrasound device. The potential study population was 11,214 men aged ≥ 60 years attended by three urban, public primary healthcare centers. Participants were recruited by randomly-selected telephone calls. Ultrasound examinations were performed by four trained family physicians with a hand-held ultrasound device (Vscan®). AAA observed were verified by confirmatory imaging using standard ultrasound or computed tomography. Cardiovascular risk factors were determined. The prevalence of AAA was computed as the sum of previously-known aneurysms, aneurysms detected by the screening program and model-based estimated undiagnosed aneurysms. We screened 1,010 men, with mean age of 71.3 (SD 6.9) years; 995 (98.5%) men had normal aortas and 15 (1.5%) had AAA on Vscan®. Eleven out of 14 AAA-cases (78.6%) had AAA on confirmatory imaging (one patient died). The total prevalence of AAA was 2.49% (95%CI 2.20 to 2.78). The median aortic diameter at diagnosis was 3.5 cm in screened patients and 4.7 cm (p<0.001) in patients in whom AAA was diagnosed incidentally. Multivariate logistic regression analysis identified coronary heart disease (OR = 4.6, 95%CI 1.3 to 15.9) as the independent factor with the highest odds ratio. A screening program led by trained family physicians using hand-held ultrasound was a feasible, safe and reliable tool for the early detection of AAA. PMID:28453577
Ultrasound findings in children with toxocariasis: report on 18 cases.
Baldisserotto, M; Conchin, C F; Soares, M da G; Araujo, M A; Kramer, B
1999-05-01
To evaluate abdominal ultrasound (US) findings in children infected with Toxocara canis. Eighteen children, 18 months to 7 years of age, with serological diagnosis of T.canis infection underwent abdominal US. Eosinophil counts, hemoglobin levels and immunoglobulin E titers were measured for all patients. Abdominal ultrasound revealed multiple hypoechoic areas in the livers of 15 patients (83.3%). Hepatohilar lymph-node enlargement was present in 14 patients (77.7%), 2 of whom also showed peripancreatic lymph-node enlargement. Hepatomegaly was present in 13 patients (72.7%) and splenomegaly in 9 (50%). The most prevalent findings of abdominal ultrasound examination of children with T.canis infection are hepatic granulomas and abdominal lymph-node enlargement. This infection should be considered in the differential diagnosis of any children who exhibit these findings on abdominal US examination, especially for those with eosinophilia.
Malformations detected by abdominal ultrasound in children with congenital heart disease.
Rosa, Rosana Cardoso Manique; Rosa, Rafael Fabiano Machado; Flores, José Antônio Monteiro; Golendziner, Eliete; Oliveira, Ceres Andréia Vieira de; Varella-Garcia, Marileila; Paskulin, Giorgio Adriano; Zen, Paulo Ricardo Gazzola
2012-12-01
Extracardiac malformations may be present in patients with congenital heart disease (CHD), bringing greater risk of comorbidity and mortality. Verify frequency and types of abdominal abnormalities detected in children with and without CHD through abdominal ultrasound (AUS), compare the patients in relation to their dysmorphic/cytogenetic findings and perform an estimative of the cost-effectiveness of the screening through AUS. We conducted a cross-sectional study with a control cohort. The cases consisted of patients with CHD admitted for the first time in a pediatric intensive care unit; the controls consisted of children without CHD who underwent AUS at the hospital shortly thereafter a case. All patients with CHD underwent AUS, high-resolution karyotype and fluorescence in situ hybridization (FISH) for microdeletion 22q11.2. AUS identified clinically significant abnormalities in 12.2% of the cases and 5.2% of controls (p= 0.009), with a power of significance of 76.6%. Most malformations with clinical significance were renal anomalies (10.4% in cases and 4.9% in controls; p= 0.034). In Brazil, the cost of an AUS examination for the Unified Health System is US$ 21. Since clinically significant abnormalities were observed in one in every 8.2 CHD patients, the cost to identify an affected child was calculated as approximately US$ 176. Patients with CHD present a significant frequency of abdominal abnormalities detected by AUS, an inexpensive and noninvasive diagnostic method with good sensitivity. The cost of screening for these defects is considerably lower than the cost to treat the complications of late diagnoses of abdominal malformations such as renal disease.
Zhao, Wen-Peng; Chen, Jin-Yun; Chen, Wen-Zhi
2014-09-01
The aim of this study was to evaluate the effect of abdominal liposuction on sonographically guided high-intensity focused ultrasound (HIFU) ablation. A total of 10 women with uterine fibroids or adenomyosis who had received abdominal liposuction were analyzed after sonographically guided HIFU ablation. Of the 10 women, 6 had a diagnosis of uterine fibroids, and 4 had a diagnosis of uterine adenomyosis. All of them had a history of a horizontal-margin split-cesarean delivery. In addition, 26 women with a history of a single horizontal-margin split-cesarean delivery who had a diagnosis of uterine fibroids or adenomyosis but had not received liposuction were analyzed together as a control group. Of the 10 women, 1 woman with uterine fibroids developed local skin erythema after treatment; 1 women with uterine adenomyosis developed a skin burn after treatment; and the remaining women had obvious skin-burning pain during treatment. All women who had not received liposuction finished the treatment with no serious adverse events during or after treatment. The pain scores and incidence of skin-burning pain were significantly higher in the liposuction group than the control group (P= .021 and .038, respectively). Abdominal liposuction may increase the risk of skin burns during sonographically guided HIFU ablation. © 2014 by the American Institute of Ultrasound in Medicine.
Tsai, C-L; Wang, H-P; Lien, W-C; Chen, C-C; Lai, T-I; Chen, W-J
2005-10-01
Ring down artefacts are sometimes found when emergency physicians perform abdominal ultrasound to differentiate between various abdominal problems. We describe a patient who presented with right upper quadrant abdominal pain and whose ultrasound examination showed ring down artefacts posterior to the right hemidiaphragm, which led to the eventual diagnosis of pneumonia. Ring down artefacts on ultrasound may be used to predict pulmonary abnormalities. Awareness of this sonographic finding may assist in accurate diagnosis and administration of appropriate treatment without delay.
Barton, Amanda; Serrao, Chloe; Thompson, Judith; Briffa, Kathy
2015-12-01
The aim of this study was to assess pelvic floor muscle (PFM) function using transabdominal ultrasound (TAUS) in women attending group exercise classes. Specific aims were to: (1) identify the ability to perform a correct elevating PFM contraction and (2) assess bladder-base movement during an abdominal curl exercise. Ninety women participating in group exercise were recruited to complete a survey and TAUS assessment performed by two qualified Continence and Women's Health physiotherapists with clinical experience in ultrasound scanning. The assessment comprised three attempts of a PFM contraction and an abdominal curl exercise in crook lying. Bladder-base displacement was measured to determine correct or incorrect activation patterns. Twenty-five percent (n = 23) of women were unable to demonstrate an elevating PFM contraction, and all women displayed bladder-base depression on abdominal curl (range 0.33-31.2 mm). Parous women displayed, on average, significantly more bladder-base depression than did nulliparous women [15.5 (7.3) mm vs 11.4 (5.8) mm, p < 0.009). Sixty percent (n = 54) reported stress urinary incontinence (SUI). There was no association between SUI and the inability to perform an elevating PFM contraction (p = 0.278) or the amount of bladder-base depression with abdominal curl [14.1 (7.6) mm SUI vs 14.2 (6.7) mm non-SUI]. TAUS identified that 25 % of women who participated in group exercise were unable to perform a correctly elevating PFM contraction, and all depressed the bladder-base on abdominal curl. Therefore, exercising women may be at risk of PFM dysfunction when performing abdominal curl activities.
Ultrasound Estimates of Visceral and Subcutaneous-Abdominal Adipose Tissues in Infancy
De Lucia Rolfe, Emanuella; Modi, Neena; Uthaya, Sabita; Hughes, Ieuan A.; Dunger, David B.; Acerini, Carlo; Stolk, Ronald P.; Ong, Ken K.
2013-01-01
Other imaging techniques to quantify internal-abdominal adiposity (IA-AT) and subcutaneous-abdominal adiposity (SCA-AT) are frequently impractical in infants. The aim of this study was twofold: (a) to validate ultrasound (US) visceral and subcutaneous-abdominal depths in assessing IA-AT and SCA-AT from MRI as the reference method in infants and (b) to analyze the association between US abdominal adiposity and anthropometric measures at ages 3 months and 12 months. Twenty-two infants underwent MRI and US measures of abdominal adiposity. Abdominal US parameters and anthropometric variables were assessed in the Cambridge Baby Growth Study (CBGS), n = 487 infants (23 girls) at age 3 months and n = 495 infants (237 girls) at 12 months. US visceral and subcutaneous-abdominal depths correlated with MRI quantified IA-AT (r = 0.48, P < 0.05) and SCA-AT (r = 0.71, P < 0.001) volumes, respectively. In CBGS, mean US-visceral depths increased by ~20 % between ages 3 and 12 months (P < 0.0001) and at both ages were lower in infants breast-fed at 3 months than in other infants. US-visceral depths at both 3 and 12 months were inversely related to skinfold thickness at birth (P = 0.03 and P = 0.009 at 3 and 12 months, resp.; adjusted for current skinfold thickness). In contrast, US-subcutaneous-abdominal depth at 3 months was positively related to skinfold thickness at birth (P = 0.004). US measures can rank infants with higher or lower IA-AT and SCA-AT. Contrasting patterns of association with visceral and subcutaneous-abdominal adiposities indicate that they may be differentially regulated in infancy. PMID:23710350
DOE Office of Scientific and Technical Information (OSTI.GOV)
Su, Lin; Kien Ng, Sook; Zhang, Ying
Purpose: Ultrasound is ideal for real-time monitoring in radiotherapy with high soft tissue contrast, non-ionization, portability, and cost effectiveness. Few studies investigated clinical application of real-time ultrasound monitoring for abdominal stereotactic body radiation therapy (SBRT). This study aims to demonstrate the feasibility of real-time monitoring of 3D target motion using 4D ultrasound. Methods: An ultrasound probe holding system was designed to allow clinician to freely move and lock ultrasound probe. For phantom study, an abdominal ultrasound phantom was secured on a 2D programmable respiratory motion stage. One side of the stage was elevated than another side to generate 3D motion.more » The motion stage made periodic breath-hold movement. Phantom movement tracked by infrared camera was considered as ground truth. For volunteer study three healthy subjects underwent the same setup for abdominal SBRT with active breath control (ABC). 4D ultrasound B-mode images were acquired for both phantom and volunteers for real-time monitoring. 10 breath-hold cycles were monitored for each experiment. For phantom, the target motion tracked by ultrasound was compared with motion tracked by infrared camera. For healthy volunteers, the reproducibility of ABC breath-hold was evaluated. Results: Volunteer study showed the ultrasound system fitted well to the clinical SBRT setup. The reproducibility for 10 breath-holds is less than 2 mm in three directions for all three volunteers. For phantom study the motion between inspiration and expiration captured by camera (ground truth) is 2.35±0.02 mm, 1.28±0.04 mm, 8.85±0.03 mm in LR, AP, SI directly, respectively. The motion monitored by ultrasound is 2.21±0.07 mm, 1.32±0.12mm, 9.10±0.08mm, respectively. The motion monitoring error in any direction is less than 0.5 mm. Conclusion: The volunteer study proved the clinical feasibility of real-time ultrasound monitoring for abdominal SBRT. The phantom and volunteer
Seven, Ekim; Thuesen, Betina H; Linneberg, Allan; Jeppesen, Jørgen L
2016-11-01
Abdominal obesity is a major risk factor for hypertension. However, different distributions of abdominal adipose tissue may affect hypertension risk differently. The main purpose of this study was to explore the association of subcutaneous abdominal adipose tissue (SAT) and visceral adipose tissue (VAT) with incident hypertension in a population-based setting. We hypothesized that VAT, rather than SAT, would be associated with incident hypertension. VAT and SAT were determined by ultrasound imagining in 3363 randomly selected Danes (mean age 49 years, 56% women, mean body mass index 25.8 kg/m 2 ). We constructed multiple logistic regression models to compute standardized odds ratios with 95% confidence intervals per SD increase in SAT and VAT. Of the 2119 normotensive participants at baseline, 1432, with mean SAT of 2.8 cm and mean VAT of 5.7 cm, returned 5 years later for a follow-up examination and among them 203 had developed hypertension. In models including both VAT and SAT, the Framingham Hypertension Risk Score variables (age, sex, smoking status, family history of hypertension, and baseline blood pressure) and glycated hemoglobin, odds ratio (95% confidence interval) for incident hypertension for 1 SD increase in VAT and SAT was 1.27 (1.08-1.50, P=0.004) and 0.97 (0.81-1.15, P=0.70), respectively. Adjusting for body mass index instead of SAT attenuated the association between VAT and incident hypertension, but it was still significant (odds ratio, 1.22 [1.01-1.48, P=0.041] for each SD increase in VAT). In conclusion, ultrasound-determined VAT, but not SAT, was associated with incident hypertension in a random sample of Danish adults. © 2016 American Heart Association, Inc.
The use of ultrasound imaging of the abdominal drawing-in maneuver in subjects with low back pain.
Teyhen, Deydre S; Miltenberger, Chad E; Deiters, Henry M; Del Toro, Yadira M; Pulliam, Jennifer N; Childs, John D; Boyles, Robert E; Flynn, Timothy W
2005-06-01
Randomized controlled trial among patients with low back pain (LBP). (1) Determine the reliability of real-time ultrasound imaging for assessing activation of the lateral abdominal muscles; (2) characterize the extent to which the abdominal drawing-in maneuver (ADIM) results in preferential activation of the transverse abdominis (TrA); and (3) determine if ultrasound biofeedback improves short-term performance of the ADIM in patients with LBP. Ultrasound imaging is reportedly useful for measuring and training patients to preferentially activate the TrA muscle. However, research to support these claims is limited. Thirty patients with LBP referred for lumbar stabilization training were randomized to receive either traditional training (n = 15) or traditional training with biofeedback (n = 15). Ultrasound imaging was used to measure changes in thickness of the lateral abdominal muscles. Differences in preferential changes in muscle thickness of the TrA between groups and across time were assessed using analysis of variance. Intrarater reliability measuring lateral abdominal muscle thickness exceeded 0.93. On average, patients in both groups demonstrated a 2-fold increase in the thickness of the TrA during the ADIM. Performance of the ADIM did not differ between the groups. These data provide construct validity for the notion that the ADIM results in preferential activation of the TrA in patients with LBP. Although, the addition of biofeedback did not enhance the ability to perform the ADIM at a short-term follow-up, our data suggest a possible ceiling effect or an insufficient training stimulus. Further research is necessary to determine if there is a subgroup of patients with LBP who may benefit from biofeedback.
The utility of focused abdominal ultrasound in blunt abdominal trauma: a reappraisal.
Helling, Thomas S; Wilson, Jennifer; Augustosky, Kim
2007-12-01
Focused assessment with sonography for trauma (FAST) has become commonplace in the management of blunt abdominal trauma. However, newer computed tomography (CT) scanners have decreased imaging time for trauma patients and provide more detailed examination of abdominal contents. It was the aim of the current study to evaluate practice patterns of FAST and abdominal CT in blunt trauma victims. This was a retrospective study of all blunt trauma patients (N = 299) who received at least 1 FAST examination in the emergency department by surgeons and were admitted. Patients were tracked for subsequent CT scanning, disposition from the emergency department, any operative findings, and survival. Twenty-one of 299 patients (7%) had a positive FAST. There were 7 deaths and 14 patients were taken directly to the operating room (OR) for control of abdominal bleeding. Thirty-one of 299 (10%) had equivocal FAST. There were 4 deaths and 8 patients were taken to the OR for control of abdominal bleeding. A total of 247 of the 299 patients had a negative FAST. CT scans were performed in 193: 15 showed a visceral injury. There were 13 deaths and 29 patients were taken to the OR (4 for bleeding). Patients with a positive FAST had a higher mortality than FAST-negative patients (P < .001) and greater likelihood for operation (P < .001). Those with equivocal FAST had a greater likelihood for operation than FAST-negative patients (P < .05). FAST examinations can identify patients at risk for hemorrhage and in whom operation may be needed and, therefore, can guide mobilization of hospital resources. FAST-negative patients can be managed expectantly, using more specific imaging techniques.
Geyer, Lucas L; Körner, M; Linsenmaier, U; Wirth, S; Reiser, M F; Meindl, T
2014-05-01
Beside its value during the initial trauma work-up (focused assessment with sonography for trauma), ultrasound (US) is recommended for early follow-up examinations of the abdomen in multiple injured patients. However, multidetector CT (MDCT) has proven to reliably diagnose traumatic lesions of abdominal organs, to depict their extent, and to assess their clinical relevance. To evaluate the diagnostic impact of follow-up US studies after MDCT of the abdomen and to identify possible clinical parameters indicating the need of a follow-up US. During a 30-month period, patients with suspected multiple trauma were allocated. Patients with admission to the ICU, an initial abdominal MDCT scan, and an US follow-up examination after 6 and 24 h were included. Two patient cohorts were defined: patients with normal abdominal MDCT (group 1), patients with trauma-related pathologic abdominal MDCT (group 2). In all patients, parameters indicating alteration of vital functions or hemorrhage within the first 24 h were obtained by reviewing the medical charts. Forty-four of 193 patients were included: 24 were categorized in group 1 (mean age, 41.1 years; range, 21-90 years), 20 in group 2 (mean age, 36.6 years; range, 16-71 years). In group 1, US did not provide new information compared to emergency MDCT. In group 2, there were no contradictory 6- and 24-h follow-up US findings. In patients with positive MDCT findings and alterations of clinical parameters, US did not detect progression of a previously diagnosed pathology or any late manifestation of such a lesion. In none of the patients with negative abdominal MDCT and pathological clinical parameters US indicated an abdominal injury. Routine US follow-up does not yield additional information after abdominal trauma. In patients with MDCT-proven organ lesions, follow-up MDCT should be considered if indicated by abnormal clinical and/or laboratory findings.
Endoscopic Ultrasound-guided drainage of an abdominal fluid collection following Whipple’s resection
Jah, Asif; Jamieson, Neville; Huguet, Emmanuel; Griffiths, William; Carroll, Nicholas; Praseedom, Raaj
2008-01-01
Percutaneous aspiration and drainage of post-operative abdominal fluid collections is a well established standard technique. However, some fluid collections are not amenable to percutaneous drainage either due to location or the presence of surrounding visceral structures. Endoscopic Ultrasound (EUS) has been widely used for the drainage of pancreatitis-related abdominal fluid collections. However, there are no reports on the use of this technique in the post-operative setting. We report a case where the EUS-guided technique was used to drain a percutaneously inaccessible post-operative collection which had developed after Whipple’s resection. PMID:19058316
ShahAli, Shabnam; Arab, Amir Massoud; Talebian, Saeed; Ebrahimi, Esmaeil; Bahmani, Andia; Karimi, Noureddin; Nabavi, Hoda
2015-07-01
The study was designed to evaluate the intra-examiner reliability of ultrasound (US) thickness measurement of abdominal muscles activity when supine lying and during two isometric endurance tests in subjects with and without Low back pain (LBP). A total of 19 women (9 with LBP, 10 without LBP) participated in the study. Within-day reliability of the US thickness measurements at supine lying and the two isometric endurance tests were assessed in all subjects. The intra-class correlation coefficient (ICC) was used to assess the relative reliability of thickness measurement. The standard error of measurement (SEM), minimal detectable change (MDC) and the coefficient of variation (CV) were used to evaluate the absolute reliability. Results indicated high ICC scores (0.73-0.99) and also small SEM and MDC scores for within-day reliability assessment. The Bland-Altman plots of agreement in US measurement of the abdominal muscles during the two isometric endurance tests demonstrated that 95% of the observations fall between the limits of agreement for test and retest measurements. Together the results indicate high intra-tester reliability for the US measurement of the thickness of abdominal muscles in all the positions tested. According to the study's findings, US imaging can be used as a reliable method for assessment of abdominal muscles activity in supine lying and the two isometric endurance tests employed, in participants with and without LBP. Copyright © 2014 Elsevier Ltd. All rights reserved.
Carreiro, Artur N.; Diniz, João A. R. A.; Souza, Joyce G.; Araújo, Débora V. F.; Dias, Rômulo F. F.; Azerêdo, Liliane M. S.; Rocha, Ediane F.; La Salles, Ana Y. F.; Peña-Alfaro, Carlos E.; Carvalho, Maria A. M.; Illera, Maria J.
2018-01-01
The objective of the present study was to monitor and characterize morphological alterations in ovaries of agouti (Dasyprocta prymnolopha), reared in captivity, by using abdominal ultrasonography. All animals underwent daily vaginal cytological examination to identify the current cycle phase. For each phase of the estrous cycle, ultrasound examinations were carried out to identify and describe the morphology of both ovaries. Topographic parameters in an ultrasound window were established to locate the ovaries. The agouti estrous cycle lasted an average of 29.94 ± 6.77 days. During vaginal cytology examinations, all cell types were identified, and each phase of the estrous cycle was established by cell counts. No significant alterations were observed in the assessed ovarian morphometry measurements. In 75% of the animals examined, ovarian follicle presence was observed in the proestrus phase. PMID:29284211
Keil-Ríos, Daniel; Terrazas-Solís, Hiram; González-Garay, Alejandro; Sánchez-Ávila, Juan Francisco; García-Juárez, Ignacio
2016-04-01
The pocket ultrasound device (PUD) is a new tool that may be of use in the early detection of ascites. Abdominal ultrasound-guided paracentesis has been reported to decrease the rate of complications due to the procedure, but must be performed in a healthcare setting; this new tool may be a useful on an ambulatory basis. The aim of this study was to determine the diagnostic usefulness of the PUD in the diagnosis of ascites and the safety of guided paracentesis. We conducted a retrospective study that included adult patients suspected of having ascites and in whom an evaluation was performed with the PUD to identify it. Concordance with abdominal ultrasound (AUS) was determined with the Kappa coefficient. Sensitivity (Se), specificity (Sp) and likelihood ratios (LR) were determined and compared with physical examination, AUS, computed tomography and procurement of fluid by paracentesis. Complications resulting from the guided paracentesis were analyzed. 89 participants were included and 40 underwent a paracentesis. The PUD for ascites detection had 95.8 % Se, 81.8 % Sp, 5.27 +LR and 0.05 -LR. It had a concordance with AUS of 0.781 (p < 0.001). Technical problems during the guided paracentesis were present in only two participants (5 %) and three patients (7.5 %) developed minor complications that required no further intervention. There were no severe complications or deaths. This study suggests that the PUD is a reliable tool for ascites detection as a complement to physical examination and appears to be a safe method to perform guided paracentesis.
Diagnostic utility of abdominal ultrasonography in dogs with chronic diarrhea.
Leib, M S; Larson, M M; Grant, D C; Monroe, W E; Troy, G C; Panciera, D L; Rossmeisl, J H; Werre, S R
2012-01-01
Chronic diarrhea is common in dogs and has many causes. Ultrasonographic descriptions of many gastrointestinal diseases have been published, but the diagnostic utility of ultrasonography in dogs with chronic diarrhea has not been investigated. Diagnostic utility of abdominal ultrasound will be highest in dogs with GI neoplasia and lowest in those with inflammatory disorders. 87 pet dogs with chronic diarrhea. Prospective study in which medical records were reviewed and contribution of abdominal ultrasound toward making diagnosis was scored. In 57/87 (66%) of dogs, the same diagnosis would have been reached without ultrasonography. In 13/87 (15%) of dogs, the ultrasound examination was vital or beneficial to making the diagnosis. Univariable analysis identified that increased diagnostic utility was associated with weight loss (P = .0086), palpation of an abdominal or rectal mass (P = .0031), diseases that commonly have mass lesions visible on ultrasound examination (P < .0001), and a final diagnosis of GI neoplasia. Multivariable regression indicated that utility of abdominal ultrasonography would be 30 times more likely to be high in dogs in which an abdominal or rectal mass was palpated (odds ratio 30.5, 95% CI 5.5-169.6) (P < .0001) versus dogs without a palpable mass. In 15/87 (17%) of dogs, additional benefits of ultrasonography to case management, independent of the contribution to the diagnosis of diarrhea, were identified. Overall, the diagnostic utility of abdominal ultrasonography was low in dogs with chronic diarrhea. Identification of factors associated with high diagnostic utility is an indication to perform abdominal ultrasonography in dogs with chronic diarrhea. Copyright © 2012 by the American College of Veterinary Internal Medicine.
Anderson, C L; MacKay, C S; Roberts, G D; Fidel, J
2015-06-01
Imaging studies in humans with anal and rectal cancer indicate that magnetic resonance imaging (MRI) is a more sensitive technique than abdominal ultrasound (AUS) for the detection of abdominal lymphadenopathy. The purpose of this retrospective study was to directly compare the efficacy of these two techniques in detecting abdominal lymphadenopathy in dogs with apocrine gland adenocarcinoma of the anal sac (AGAAS). Six dogs with histologically confirmed AGAAS and histopathologic confirmation of metastasis to abdominal lymph nodes (LNs) had AUS and abdominal MRI. AUS identified lymphadenopathy in two of six dogs, whereas MRI identified lymphadenopathy in all the six dogs. Lymphadenopathy was predominantly sacral in location, with involvement of the medial iliac and hypogastric LNs in only two cases. These data suggest that MRI is more sensitive than AUS for detecting sacral abdominal lymphadenopathy in dogs with AGAAS. As such, MRI could be considered in any patient with AGAAS for initial staging of this disease. © 2013 Blackwell Publishing Ltd.
The ultrasound-assisted physical examination in the periodic health evaluation of the elderly.
Siepel, T; Clifford, D S; James, P A; Cowan, T M
2000-07-01
Except for specific procedures such as blood pressure measurement, the conventional physical examination (PE) does not have sufficient sensitivity to be useful as part of the periodic health evaluation. Ultrasound has demonstrated greater sensitivity and specificity in numerous studies but has been too expensive to be widely employed in health screening. The purpose of our study was to determine whether an examination in which conventional and ultrasound techniques are blended and applied by a primary care physician might be feasible and useful in the periodic health evaluations of senior citizens. Seventy-two patients presenting to a community-based family physician for periodic health evaluations received an ultrasound-assisted physical examination (USA-PE) from a second family physician. The results were reported to the primary physician, and the outcomes were tracked for periods of up to 2 years. Twenty-two of the 72 patients (31%) had abnormalities found by the USA-PE that were not apparent during the conventional PE. Five of these patients (7%) had serious conditions that received prompt treatment with apparent benefit. Findings included endometrial carcinoma, abdominal aortic aneurysm, carotid stenosis, hydronephrosis, and urinary retention. The USA-PE found more abnormalities in this group of patients than conventional PE. Whether it can improve outcomes for senior citizens undergoing periodic health evaluations in a cost-effective manner is yet to be determined.
... inflammation in pancreas) Spleen enlargement ( splenomegaly ) Portal hypertension Liver tumors Obstruction of bile ... Digestive system Kidney anatomy Ultrasound in pregnancy Kidney - blood and urine flow ...
Giljaca, Vanja; Nadarevic, Tin; Poropat, Goran; Nadarevic, Vesna Stefanac; Stimac, Davor
2017-03-01
To determine the diagnostic accuracy of abdominal ultrasound (US) for the diagnosis of acute appendicitis (AA), in terms of sensitivity, specificity and post-test probabilities for positive and negative result. A systematic search of MEDLINE, Embase, The Cochrane library and Science Citation Index Expanded from January 1994 to October 2014 was performed. Two authors independently evaluated studies for inclusion, extracted data and performed analyses. The reference standard for evaluation of final diagnosis was pathohistological report on tissue obtained at appendectomy. Summary sensitivity, specificity and post-test probability of AA after positive and negative result of US with corresponding 95% confidence intervals (CI) were calculated. Out of 3306 references identified through electronic searches, 17 reports met the inclusion criteria, with 2841 included participants. The summary sensitivity and specificity of US for diagnosis of AA were 69% (95% CI 59-78%) and 81% (95% CI 73-88%), respectively. At the median pretest probability of AA of 76.4%, the post-test probability for a positive and negative result of US was 92% (95% CI 88-95%) and 55% (95% CI 46-63%), respectively. Abdominal ultrasound does not seem to have a role in the diagnostic pathway for diagnosis of AA in suspected patients. The summary sensitivity and specificity of US do not exceed that of physical examination. Patients that require additional diagnostic workup should be referred to more sensitive and specific diagnostic procedures, such as computed tomography.
Kimura, Bruce J; Shaw, David J; Amundson, Stan A; Phan, James N; Blanchard, Daniel G; DeMaria, Anthony N
2015-09-01
The current practice of physical diagnosis is dependent on physician skills and biases, inductive reasoning, and time efficiency. Although the clinical utility of echocardiography is well known, few data exist on how to integrate 2-dimensional screening "quick-look" ultrasound applications into a novel, modernized cardiac physical examination. We discuss the evidence basis behind ultrasound "signs" pertinent to the cardiovascular system and elemental in synthesis of bedside diagnoses and propose the application of a brief cardiac limited ultrasound examination based on these signs. An ultrasound-augmented cardiac physical examination can be taught in traditional medical education and has the potential to improve bedside diagnosis and patient care. © 2015 by the American Institute of Ultrasound in Medicine.
Robot-based tele-echography: clinical evaluation of the TER system in abdominal aortic exploration.
Martinelli, Thomas; Bosson, Jean-Luc; Bressollette, Luc; Pelissier, Franck; Boidard, Eric; Troccaz, Jocelyne; Cinquin, Philippe
2007-11-01
The TER system is a robot-based tele-echography system allowing remote ultrasound examination. The specialist moves a mock-up of the ultrasound probe at the master site, and the robot reproduces the movements of the real probe, which sends back ultrasound images and force feedback. This tool could be used to perform ultrasound examinations in small health care centers or from isolated sites. The objective of this study was to prove, under real conditions, the feasibility and reliability of the TER system in detecting abdominal aortic and iliac aneurysms. Fifty-eight patients were included in 2 centers in Brest and Grenoble, France. The remote examination was compared with the reference standard, the bedside examination, for aorta and iliac artery diameter measurement, detection and description of aneurysms, detection of atheromatosis, the duration of the examination, and acceptability. All aneurysms (8) were detected by both techniques as intramural thrombosis and extension to the iliac arteries. The interobserver correlation coefficient was 0.982 (P < .0001) for aortic diameters. The rate of concordance between 2 operators in evaluating atheromatosis was 84% +/- 11% (95% confidence interval). Our study on 58 patients suggests that the TER system could be a reliable, acceptable, and effective robot-based system for performing remote abdominal aortic ultrasound examinations. Research is continuing to improve the equipment for general abdominal use.
Ultrasound Assessment of Abdominal Muscle Thickness in Postpartum vs Nulliparous Women.
Weis, Carol Ann; Triano, John J; Barrett, Jon; Campbell, Michelle D; Croy, Martine; Roeder, Jessica
2015-06-01
The purpose of this study was to determine the effect size in measurable change of abdominal musculature morphology using ultrasonography in postpartum women within 1 month of a healthy, vaginal delivery. One hundred fifty-six participants were recruited for this study. B-mode ultrasound imaging was used to measure abdominal muscle thickness on 80 nulliparous women and 76 mothers who had delivered within the past 4 weeks. Measures were taken for the upper and lower rectus abdominus, external and internal obliques, and transversus abdominus at rest. Statistically significant differences were found in the thickness of the rectus abdominus muscle at both sites; upper (P < .0001) and lower (P < .0001) as well as the internal oblique (P < .0001). All 3 muscles were thinner in postpartum participants (8.29 ± 1.83 mm, 8.89 ± 2.29 mm, and 7.06 ± 1.82 mm, respectively) within the first month of delivery than in controls (10.82 ± 1.93 mm, 11.13 ± 2.38 mm, and 8.36 ± 1.87 mm, respectively). Large effect sizes were found for the influence of pregnancy on the rectus muscle segments (1.35 for the upper rectus abdominus and 1.00 for the lower rectus abdominus) and a medium effect size for the internal oblique (0.71). No significant differences were observed in the remaining 2 muscles. This study showed that there are differences in morphology of the abdominal muscles in pregnant women vs nonpregnant controls. The large effect sizes reported may provide the basis for future studies examining relationships between morphology, functional change, and back pain during pregnancy. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.
Cârstea, Doina; Streba, Letiţia Adela Maria; Glodeanu, Adina; Cârstea, A P; Vancu, Mihaela; Ninulescu, Ana-Maria
2008-01-01
Atherosclerosis is the most frequent cause in the appearance of an abdominal aorta aneurysm (AAA) and plays an important role in his development. Most AAA does not cause any symptoms, especially when talking about elderly patients, however, many of those aneurysms can be detected during physical examination. Their detection is very important because the natural evolution and the major reason in treating AAA is their tendency to rupture. We present the case of an adult man with a complex clinical pathology, but not related to the AAA. The diagnosis of the AAA has been suspicion through palpation, and the abdominal ultrasound exam confirmed it. This case is particular interesting, as the AAA requires surgical intervention, while patient's health status was poor. An essential issue is establishing the importance of the AAA screening, when there are no symptoms present. For now, there are not satisfactory studies to be used as a guide.
Feliciano, David V
2017-11-01
Although abdominal trauma has been described since antiquity, formal laparotomies for trauma were not performed until the 1800s. Even with the introduction of general anesthesia in the United States during the years 1842 to 1846, laparotomies for abdominal trauma were not performed during the Civil War. The first laparotomy for an abdominal gunshot wound in the United States was finally performed in New York City in 1884. An aggressive operative approach to all forms of abdominal trauma till the establishment of formal trauma centers (where data were analyzed) resulted in extraordinarily high rates of nontherapeutic laparotomies from the 1880s to the 1960s. More selective operative approaches to patients with abdominal stab wounds (1960s), blunt trauma (1970s), and gunshot wounds (1990s) were then developed. Current adjuncts to the diagnosis of abdominal trauma when serial physical examinations are unreliable include the following: 1) diagnostic peritoneal tap/lavage, 2) surgeon-performed ultrasound examination; 3) contrast-enhanced CT of the abdomen and pelvis; and 4) diagnostic laparoscopy. Operative techniques for injuries to the liver, spleen, duodenum, and pancreas have been refined considerably since World War II. These need to be emphasized repeatedly in an era when fewer patients undergo laparotomy for abdominal trauma. Finally, abdominal trauma damage control is a valuable operative approach in patients with physiologic exhaustion and multiple injuries.
Ishida, Hiroshi; Watanabe, Sususmu
2012-09-01
Controlled laboratory study, technical note. The purpose of this study was to quantify changes in the thickness of the transversus abdominis, internal oblique, and external oblique muscles induced by different inward pressures of the transducer during ultrasound imaging (USI). USI of the lateral abdominal muscles is increasingly used in managing musculoskeletal dysfunction. However, to the best of our knowledge, no study has evaluated the influence of different inward pressures of the transducer on the lateral abdominal muscle thickness during USI. Thirty healthy male volunteers participated in this study. The thickness of the transversus abdominis, internal oblique, and external oblique muscles was measured with USI by the same rater in 4 conditions of inward pressures of 0.5, 1.0, 2.0, and 4.0 N. Intraclass correlation coefficients (ICC1,1), with 95% confidence intervals, were calculated, and a repeated-measures analysis of variance was used to assess the influence of inward pressure on the thickness of the lateral abdominal muscles. The thickness of the transversus abdominis, internal oblique, and external oblique muscles was significantly different among the 4 conditions (P<.038). The mean difference between the 0.5-N and 4.0-N conditions was greater than the minimal detectable change of the 0.5-N condition in the lateral abdominal muscles. The difference in magnitude produced by the forces under different conditions was meaningful. When using a technique that involves a handheld transducer, the examiner should attempt to maintain consistent inward pressure of the transducer during USI to quantify the thickness of lateral abdominal muscles. J Orthop Sports Phys Ther 2012;42(9):815-818, Epub 19 April 2012. doi:10.2519/jospt.2012.4064.
Landmann, Alessandra; Visoiu, Mihaela; Malek, Marcus M
2018-03-01
Abdominal wall nerve blocks have been gaining popularity for the treatment of perioperative pain in children. Our aim was to compare a technique of surgeon-performed, laparoscopic abdominal wall nerve blocks to anesthesia-placed, ultrasound-guided abdominal wall nerve blocks and the current standard of local wound infiltration. After institutional review board approval was obtained, a retrospective chart review was performed of pediatric patients treated at a single institution during a 2-year period. Statistics were calculated using analysis of variance with post-hoc Bonferonni t tests for pair-wise comparisons. Included in this study were 380 patients who received ultrasound-guided abdominal wall nerve blocks (n = 125), laparoscopic-guided abdominal wall nerve blocks (n = 88), and local wound infiltration (n = 117). Groups were well matched for age, sex, and weight. There was no significant difference in pain scores within the first 8 hours or narcotic usage between groups. Local wound infiltration demonstrated the shortest overall time required to perform (P < .0001). Patients who received a surgeon-performed abdominal wall nerve block demonstrated a shorter duration of hospital stay when compared to the other groups (P = .02). Our study has demonstrated that laparoscopic-guided abdominal wall nerve blocks show similar efficacy to ultrasound-guided nerve blocks performed by pain management physicians without increasing time in the operating room. Copyright © 2017 Elsevier Inc. All rights reserved.
Volunteer patients and small groups contribute to abdominal examination's success.
Shields, Helen M; Fernandez-Becker, Nielsen Q; Flier, Sarah N; Vaughn, Byron P; Tukey, Melissa H; Pelletier, Stephen R; Horst, Douglas A
2017-01-01
Prior to 2007, we taught the abdominal examination in a hospital based group to 40 students, at one hospital. We used volunteer patients, small groups, repetition, and required faculty development sessions. In 2007, our medical school changed its "Introduction to Physical Examination" session so that the entire class was to be taught in a geographically central session. Our hospital was selected to lead the abdominal examination portion of the session. Our aim was to answer three questions. First, could we quadruple the recruitment of volunteer patients, and faculty? Second, was it volunteer patients, small groups, repetition, or faculty training that was most valued by the students? Third, would volunteer patients and/or faculty agree to participate a second time? A total of 43-46 patients and 43-46 faculty were recruited and 43-46 examining rooms were obtained for each of the 5 years of this study. Teachers were required to attend a 1-hour faculty development session. The class of about 170 students was divided into 43-46 groups each year. The teacher demonstrated the abdominal examination and each student practiced the examination on another student. Each student then repeated the full abdominal examination on a volunteer patient. Over the 5-year time period (2008-2012), the abdominal examination ranked first among all organ systems' "Introductory Sessions". The abdominal examination ratings had the best mean score (1.35) on a Likert scale where 1 is excellent and 5 is poor. The students gave the most positive spontaneous comments to having volunteer patients, with small groups coming in as the second most appreciated educational element. We successfully quadrupled the number of faculty, patients, and examining rooms and created a highly rated educational program as measured by anonymous student evaluations, patient and faculty participation, and the medical school's selecting the abdominal examination methods as an "Advanced Examination" for the Pathways
... asked to drink four to six glasses of liquid about an hour before the test to fill your bladder. You may be asked to avoid eating for eight to 12 hours before the test to avoid gas buildup in the intestines. For ultrasound of the ...
Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng
2014-01-01
Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.
Emergency ultrasound-based algorithms for diagnosing blunt abdominal trauma.
Stengel, Dirk; Rademacher, Grit; Ekkernkamp, Axel; Güthoff, Claas; Mutze, Sven
2015-09-14
Ultrasonography (performed by means of a four-quadrant, focused assessment of sonography for trauma (FAST)) is regarded as a key instrument for the initial assessment of patients with suspected blunt abdominal and thoraco-abdominal trauma in the emergency department setting. FAST has a high specificity but low sensitivity in detecting and excluding visceral injuries. Proponents of FAST argue that ultrasound-based clinical pathways enhance the speed of primary trauma assessment, reduce the number of unnecessary multi-detector computed tomography (MDCT) scans, and enable quicker triage to surgical and non-surgical care. Given the proven accuracy, increasing availability of, and indication for, MDCT among patients with blunt abdominal and multiple injuries, we aimed to compile the best available evidence of the use of FAST-based assessment compared with other primary trauma assessment protocols. To assess the effects of diagnostic algorithms using ultrasonography including in FAST examinations in the emergency department in relation to the early, late, and overall mortality of patients with suspected blunt abdominal trauma. The most recent search was run on 30th June 2015. We searched the Cochrane Injuries Group Specialised Register, The Cochrane Library, MEDLINE (OvidSP), EMBASE (OvidSP), ISI Web of Science (SCI-EXPANDED, SSCI, CPCI-S, and CPSI-SSH), clinical trials registers, and screened reference lists. Trial authors were contacted for further information and individual patient data. We included randomised controlled trials (RCTs). Participants were patients with blunt torso, abdominal, or multiple trauma undergoing diagnostic investigations for abdominal organ injury. The intervention was diagnostic algorithms comprising emergency ultrasonography (US). The control was diagnostic algorithms without US examinations (for example, primary computed tomography (CT) or diagnostic peritoneal lavage (DPL)). Outcomes were mortality, use of CT or invasive procedures (DPL
Can activity within the external abdominal oblique be measured using real-time ultrasound imaging?
John, E K; Beith, I D
2007-11-01
Differences in the function of the anterolateral abdominal muscles have been the subject of much investigation, but primarily using electromyography. Recently changes in thickness of transversus abdominis and internal oblique measured from real-time ultrasound images have been shown to represent activity within these muscles. However it is still unclear if such a change in thickness in external oblique similarly represents activity within that muscle. The purpose of this study was to investigate the relationship between change in thickness and muscle activity in the external oblique using real-time ultrasound and surface electromyography. Simultaneous measurements of electromyography and real-time ultrasound images of external oblique were studied in up to 24 subjects during two tasks compared to the muscle at rest (1) isometric trunk rotation and (2) drawing in the lower abdomen. Changes in muscle thickness correlated significantly with electromyography during isometric trunk rotation in the majority of subjects but with a significant difference between subjects. In contrast, the relationship between change in thickness and electrical activity in the muscle when drawing in the lower abdomen was significant in less than 50% of subjects and the muscle often got thinner. Thickness changes of external oblique can be used as a valid indicator of electromyography activity during isometric trunk rotation, though the relationship is not as good as previously published data for transversus abdominis. Thickness changes of external oblique measured during lower abdominal drawing in cannot be used to detect activity within this muscle.
Demers, Marie-Elaine; Dubé, Samuel; Bourdages, Mélodie; Gasse, Cedric; Boutin, Amélie; Girard, Mario; Bujold, Emmanuel; Demers, Suzanne
2018-01-10
To compare the first-trimester uterine artery pulsatility index (PI) measured by abdominal and transvaginal ultrasound (US). We performed a prospective study of singleton pregnant women recruited at 11 to 13 weeks' gestation. The mean uterine artery PI was obtained by abdominal followed by transvaginal US. The mean of the left and right uterine artery PIs was used, and differences between approaches were computed. The intraclass correlation coefficient and a Bland-Altman plot were used to compare the two approaches. Data were available for 940 participants, including 928 (99%) with uterine artery PIs obtained on both uterine sides. The mean uterine artery PI decreased with gestational age in both approaches (P < .001). We observed a moderate correlation between abdominal and transvaginal mean uterine artery PIs (intraclass correlation coefficient, 0.72; 95% confidence interval, 0.69 to 0.75). Values obtained by abdominal US (median, 1.70, interquartile range, 1.35 to 2.09) were greater than those obtained by transvaginal US (median, 1.65; interquartile range, 1.37 to 1.99). There was a significant increase in differences as average measurements became higher (P < .01). The first-trimester mean uterine artery PI decreases with gestational age in both approaches. Abdominal US could be associated with greater uterine artery PI values than transvaginal US, especially at higher measurements. The first-trimester uterine artery PI for prediction of adverse perinatal outcomes should be adjusted for gestational age and possibly for the US approach. © 2018 by the American Institute of Ultrasound in Medicine.
Reproducibility of ECG-gated ultrasound diameter assessment of small abdominal aortic aneurysms.
Bredahl, K; Eldrup, N; Meyer, C; Eiberg, J E; Sillesen, H
2013-03-01
No standardised ultrasound procedure to obtain reliable growth estimates for abdominal aortic aneurysms (AAA) is currently available. We investigated the feasibility and reproducibility of a novel approach controlling for a combination of vessel wall delineation and cardiac cycle variation. Prospective comparative study. Consecutive patients (N = 27) with an AAA, attending their 6-month control as part of a medical treatment trial, were scanned twice by two ultrasound operators. Then, all ultrasound recordings were transferred to a core facility and analysed by a third person. The AAA diameter was determined in four different ways: from the leading edge of adventitia on the anterior wall to either the leading edge of the adventitia (method A) or leading edge of the intima (method B) on the posterior wall, with both measurements performed in systole and diastole. Inter-operator reproducibility was ± 3 mm for all methods applied. There was no difference in outcome between methods A and B; likewise, end-diastolic measurement did not improve reproducibility in preference to peak-systolic measurement. The use of a standardised ultrasound protocol including ECG-gating and subsequent off-line reading with minute calliper placement reduces variability. This may be of use in developing protocols to better detect even small AAA growth rates during clinical trials. Copyright © 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Twisted intra-abdominal cyst in a neonate: a surprise revelation.
Mohamed, Ferzine; Telugu, Ramesh Babu; Karl, Immanuel Sampath
2017-08-08
We, herein, present a male neonate with an antenatally detected intra-abdominal cyst who presented at 18 days of life at which time, the ultrasound revealed a 5×4 cm cyst. Since he was asymptomatic, we planned to repeat the ultrasound a month later and operate if the cyst showed no regression. However, a week later, he presented with an acute abdomen, irritable cry and a repeat ultrasound showing a larger (8×6 cm) cystic mass with debris within. He was taken up for an emergency laparotomy. Intraoperatively, the cyst was found arising from the left lateral abdominal wall free from all structures with a twisted pedicle. Histopathology surprisingly revealed seminiferous tubules within the cyst wall with the vas deferens, thus confirming the diagnosis of a torsion of intra-abdominal testis. Hence, we emphasise the importance of examining for an undescended testis when dealing with a male neonate presenting with a cystic intra-abdominal mass. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Mao, Feng; Dong, Yi; Ji, Zhengbiao; Cao, Jiaying; Wang, Wen-Ping
2017-01-01
Aim. To investigate the value of contrast-enhanced ultrasound (CEUS) guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT) decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6) who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US) guidance group ( n = 75). All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3%) and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm) nonenhanced necrotic areas. More inner (20.0% versus 6.7%) and surrounding (18.3% versus 2.7%) major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%). The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%). Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.
Disparity between Clinical and Ultrasound Examinations in Neonatal Hip Screening.
Kyung, Bong Soo; Lee, Soon Hyuck; Jeong, Woong Kyo; Park, Si Young
2016-06-01
For early detection of developmental dysplasia of the hip (DDH), neonatal hip screening using clinical examination and/or ultrasound has been recommended. Although there have been many studies on the reliability of both screening techniques, there is still controversy in the screening strategies; clinical vs. selective or universal ultrasound screening. To determine the screening strategy, we assessed the agreement among the methods; clinical examination by an experienced pediatric orthopedic surgeon, sonographic morphology, and sonographic stability. From January 2004 to June 2009, a single experienced pediatric orthopedic surgeon performed clinical hip screenings for 2,686 infants in the neonatal unit and 43 infants who were referred due to impressions of hip dysplasia before 3 months of age. Among them, 156 clinically unstable or high-risk babies selectively received bilateral hip ultrasound examinations performed by the same surgeon using the modified Graf method. The results were analyzed statistically to detect any correlations between the clinical and sonographic findings. Although a single experienced orthopedic surgeon conducted all examinations, we detected only a limited relationship between the results of clinical and ultrasound examinations. Ninety-three percent of the clinically subluxatable hips were normal or immature based on static ultrasound examination, and 74% of dislocating hips and 67% of limited abduction hips presented with the morphology below Graf IIa. A total of 80% of clinically subluxatable, 42% of dislocating and 67% of limited abduction hips appeared stable or exhibited minor instability on dynamic ultrasound examination. About 7% of clinically normal hips were abnormal upon ultrasound examination; 5% showed major instability and 3% showed dysplasia above Graf IIc. Clinical stability had small coefficients between ultrasound examinations; 0.39 for sonographic stability and 0.37 for sonographic morphology. Between sonographic
Using Ultrasound to Enhance Medical Students' Femoral Vascular Physical Examination Skills.
Ahn, Justin S; French, Andrew J; Thiessen, Molly E W; Browne, Vaughn; Deutchman, Mark; Guiton, Gretchen; Madigosky, Wendy; Kendall, John L
2015-10-01
To determine whether the addition of ultrasound to traditional physical examination instruction improves junior medical students' abilities to locate the femoral pulse. Initially, 150 second-year medical students were taught the femoral pulse examination using traditional bedside teaching on standardized patients and online didactic videos. Students were then randomized into 2 groups: group 1 received ultrasound training first and then completed the standardized examination; and group 2 performed the standardized examination first and then received ultrasound training. On the standardized patients, the femoral artery was marked with invisible ink before the sessions using ultrasound. Compared to these markers, students were then evaluated on the accuracy of femoral artery pulse palpation and the estimated location of the femoral vein. All students completed a self-assessment survey after the ultrasound sessions. Ultrasound training improved the students' ability to palpate the femoral pulse (P= .02). However, ultrasound did not facilitate correct estimation of the femoral vein's anatomic location (P = .09). Confidence levels in localizing the femoral artery and vein were equal between groups at baseline, and both increased after the ultrasound sessions. The addition of ultrasound teaching to traditional physical examination instruction enhanced medical student competency and confidence with the femoral vascular examination. However, understanding of anatomy may require emphasis on precourse didactic material, but further study is required. © 2015 by the American Institute of Ultrasound in Medicine.
Simulation-Based Abdominal Ultrasound Training - A Systematic Review.
Østergaard, M L; Ewertsen, C; Konge, L; Albrecht-Beste, E; Bachmann Nielsen, M
2016-06-01
The aim is to provide a complete overview of the different simulation-based training options for abdominal ultrasound and to explore the evidence of their effect. This systematic review was performed according to the PRISMA guidelines and Medline, Embase, Web of Science, and the Cochrane Library was searched. Articles were divided into three categories based on study design (randomized controlled trials, before-and-after studies and descriptive studies) and assessed for level of evidence using the Oxford Centre for Evidence Based Medicine (OCEBM) system and for bias using the Cochrane Collaboration risk of bias assessment tool. Seventeen studies were included in the analysis: four randomized controlled trials, eight before-and-after studies with pre- and post-test evaluations, and five descriptive studies. No studies scored the highest level of evidence, and 14 had the lowest level. Bias was high for 11 studies, low for four, and unclear for two. No studies used a test with established evidence of validity or examined the correlation between obtained skills on the simulators and real-life clinical skills. Only one study used blinded assessors. The included studies were heterogeneous in the choice of simulator, study design, participants, and outcome measures, and the level of evidence for effect was inadequate. In all studies simulation training was equally or more beneficial than other instructions or no instructions. Study designs had significant built-in bias and confounding issues; therefore, further research should be based on randomized controlled trials using tests with validity evidence and blinded assessors. © Georg Thieme Verlag KG Stuttgart · New York.
Diagnostic ultrasonography in cattle with abdominal fat necrosis.
Tharwat, Mohamed; Buczinski, Sébastien
2012-01-01
This study describes the ultrasonographic findings in 14 cows with abdominal fat necrosis. Ultrasonography of the abdomen revealed the presence of heterogeneous hyperechoic masses and hyperechoic omentum with localized masses floating in a hypoechoic peritoneal fluid. A hyperechogenic rim was imaged around both kidneys. The intestines were coated with hyperechoic capsules and the intestinal lumens were constricted. Ultrasonographic examination of the pancreatic parenchyma showed an overall increased echogenicity which was homogenously distributed in 3 cases. A diagnosis of abdominal fat necrosis was made with ultrasound-guided biopsy of the echogenic masses, and thereafter at postmortem examination. Results from this study demonstrate the efficacy of ultrasonography as an imaging modality for antemortem diagnosis of abdominal lipomatosis in cattle. To the authors' knowledge, this study is the first that illustrates ultrasonographic findings in cattle affected with abdominal lipomatosis.
Shi, Yulan; Huang, Yanqin; Zhou, Meiqi; Ying, Xiao; Hu, Xiaoye
2016-04-01
Desmoid tumors are rare clonal fibroblastic proliferations that can arise at abdominal or extra-abdominal sites. Complete surgical resection is the primary treatment for resectable desmoid tumors, but a high rate of local recurrence has been reported even after complete resection. For patients with a recurrent tumor, the goals of treatment are to control the recurrence, maintain quality of life, and prolong survival. Radiofrequency ablation, radiotherapy, chemotherapy, and other medical therapies can be used as alternative methods, but there are considerable controversies over the roles of these methods in the management of desmoid tumors. High-intensity focused ultrasound (HIFU) is a minimally invasive and effective method for treatment of solid tumors. We used HIFU to treat four patients with intra-abdominal desmoid tumors from June 2011 to September 2013. Post-procedural pain was seen in all patients. One patient had an intra-abdominal abscess and another suffered a slight injury to the femoral nerve. The patients were followed up for 19-46 months (mean 34 months) until April 2015. The tumor in one patient disappeared, and no tumor progression was observed in the other patients.
Feyzi, Ali; Rad, Masoud Pezeshki; Ahanchi, Navid; Firoozabadi, Jalil
2015-01-01
Despite the advantages of ultrasound scan, its use as a screening tool in blunt abdominal trauma is controversial. The aim of this study was to evaluate the diagnostic value of early and late ultrasound in patients with blunt abdominal trauma (BAT). In this study which was performed in a level I trauma center, firstly, 2418 patients with BAT had ultrasound (US) examination by two trauma expert radiologists. Results were compared with the best available gold standards such as laparotomy, CT, repeated ultrasound or clinical course follow-up. Then, 400 patients with BAT were examined by a trained residency student. In the first phase, sensitivity, specificity, negative predictive value, positive predictive value and accuracy of ultrasound were 97%, 98.1%, 99.7%, 83% and 98% respectively. In the second phase, they were 97.3%, 97.2%, 97.7%, 96.8% and 97.3% for the early and 98.5%, 97.6%, 98.5%, 97.5% and 98% for the late ultrasound respectively. Results obtained from this study indicate that negative ultrasound findings associated with negative clinical observation virtually exclude abdominal injury, and confirmation by performing other tests is unnecessary. High sensitivity and negative predictive value is achieved if ultrasound is performed by expert trauma radiologist.
Weis, Carol Ann; Nash, Jennifer; Triano, John J; Barrett, Jon
2017-05-01
The aim of this preliminary study was to determine the differences in abdominal musculature thickness, within 1 month of delivery, in women who experienced back pain during pregnancy compared with those who did not. B-mode ultrasound imaging was used to measure abdominal muscle thickness on 76 postpartum participants who participated in a larger study; 47 women experienced back pain during pregnancy, and 29 did not. Participant data were stratified by group, and primary comparisons were based on these grouping across the abdominal muscles, including rectus abdominis (upper and lower fibers), external oblique, internal oblique, and transversus abdominis. Means and standard deviations were also used to set parameters for future studies. In the present study, there was no difference in any abdominal muscle thickness between groups. Women with low back pain were significantly shorter (165.19 ± 6.64 cm) than women who did not have from back pain during pregnancy (169.38 ± 7.58 cm). All other demographics, such as age, weight, and date tested postpartum, were not significantly different between groups. The results of this study showed no variation in abdominal muscle thickness in women who had back pain during pregnancy and those who did not. Copyright © 2017. Published by Elsevier Inc.
Reproducibility of regional DEXA examinations of abdominal fat and lean tissue.
Tallroth, Kaj; Kettunen, Jyrki A; Kujala, Urho M
2013-01-01
The aim of this study was to develop and test the validity of a new repeatable method to delimit abdominal areas for follow-up of fat mass (FM) and lean tissue mass (LM) in DEXA examinations. 37 male volunteers underwent two DEXA examinations. Total body FM and LM measurements and corresponding abdominal measurements in a carefully defined region were calculated from the first scan. After repositioning of the subjects and a second scan, the delimited region was copied and the abdominal tissues re-calculated. The mean LM of the abdominal area was 2.804 kg (SD 0.556), and the mean FM was 1.026 kg (SD 0.537). The intra-class correlation coefficient for the repeated abdominal LM, FM, and LM/FM ratio measurements was 0.99. The mean difference (bias) for the repeated abdominal LM measurements was -13 g (95% confidence interval (CI) -193.0 to 166.8), and for the repeated abdominal FM measurements it was -35 g (95% CI -178.9 to 108.5). The results indicate that regional DEXA is a sensitive method with excellent reproducibility in the measurements of the abdominal fat and lean tissues. The method may serve as a useful tool for evaluation and follow-up of various dietary and training programmes.
Stock, Konrad Friedrich; Klein, Bettina; Steubl, Dominik; Lersch, Christian; Heemann, Uwe; Wagenpfeil, Stefan; Eyer, Florian; Clevert, Dir-Andre
2015-10-01
Time savings and clinical accuracy of a new miniature ultrasound device was investigated utilizing comparison with conventional high-end ultrasound instruments. Our objective was to determine appropriate usage and limitations of this diagnostic tool in internal medicine. We investigated 28 patients from the internal-medicine department. Patients were examined with the Acuson P10 portable device and a Sonoline Antares instrument in a cross-over design. All investigations were carried out at the bedside; the results were entered on a standardized report form. The time for the ultrasound examination (transfer time, setting up and disassembly, switching on and off, and complete investigation time) was recorded separately. Mean time for overall examination per patient with the portable ultrasound device was shorter (25.0 ± 4.5 min) than with the high-end machine (29.4 ± 4.4 min; p < 0.001). When measuring the size of liver, spleen, and kidneys, the values obtained differed significantly between portable device and the high-end instrument. In our study, we identified 113 pathological ultrasound findings with the high-end ultrasound machine, while 82 pathological findings (73%) were concordantly detected with the portable ultrasound device. The main diagnostic strengths of the portable device were in the detection of ascites (sensitivity 80%), diagnosis of fatty liver, and identification of severe parenchymal liver damage. The clinical utility of portable ultrasound machines is limited. There will be clinical roles for distinct clinical questions such as detection of ascites or pleural effusion when used by experienced examiners. However, sensitivity in detecting multiple pathologies is not comparable to high-end ultrasound machines.
Adding New Tools to the Black Bag—Introduction of Ultrasound into the Physical Diagnosis Course
Amponsah, David; Yang, James; Mendez, Jennifer; Bridge, Patrick; Hays, Gregory; Baliga, Sudhir; Crist, Karen; Brennan, Simone; Jackson, Matt; Dulchavsky, Scott
2010-01-01
INTRODUCTION Ultrasound, a versatile diagnostic modality that permits real-time visualization at the patient’s bedside, can be used as an adjunct in teaching physical diagnosis (PD). Aims: (1) to study the feasibility of incorporating ultrasound into PD courses and (2) determine whether learners can demonstrate image recognition and acquisition skills. PROGRAM DESCRIPTION Three hundred seven second-year medical students were introduced to cardiovascular and abdominal ultrasound scanning after training in the physical examination. This consisted of a demonstration of the ultrasound examination, followed by practice on standardized patients (SPs). Pre-post tests were administered to evaluate students’ knowledge and understanding of ultrasound. Students performed an ultrasound examination during the PD final examination. PROGRAM EVALUATION Pre-post test data revealed significant improvements in image recognition. On the final exam, the highest scores (98.4%) were obtained for the internal jugular vein and lowest scores (74.6%) on the Focused Assessment with Sonography for Trauma images. Eighty-nine percent of students’ surveyed felt ultrasound was a valuable tool for physicians. DISCUSSION An introductory ultrasound course is effective in improving medical students' acquisition and recognition of basic cardiovascular and abdominal ultrasound images. This innovative program demonstrates the feasibility of incorporating portable ultrasound as a learning tool during medical school. Electronic supplementary material The online version of this article (doi:10.1007/s11606-010-1451-5) contains supplementary material, which is available to authorized users. PMID:20697974
Reproducibility of Regional DEXA Examinations of Abdominal Fat and Lean Tissue
Tallroth, Kaj; Kettunen, Jyrki A.; Kujala, Urho M.
2013-01-01
Objective The aim of this study was to develop and test the validity of a new repeatable method to delimit abdominal areas for follow-up of fat mass (FM) and lean tissue mass (LM) in DEXA examinations. Methods 37 male volunteers underwent two DEXA examinations. Total body FM and LM measurements and corresponding abdominal measurements in a carefully defined region were calculated from the first scan. After repositioning of the subjects and a second scan, the delimited region was copied and the abdominal tissues re-calculated. Results The mean LM of the abdominal area was 2.804 kg (SD 0.556), and the mean FM was 1.026 kg (SD 0.537). The intra-class correlation coefficient for the repeated abdominal LM, FM, and LM/FM ratio measurements was 0.99. The mean difference (bias) for the repeated abdominal LM measurements was −13 g (95% confidence interval (CI) −193.0 to 166.8), and for the repeated abdominal FM measurements it was −35 g (95% CI −178.9 to 108.5). Conclusions The results indicate that regional DEXA is a sensitive method with excellent reproducibility in the measurements of the abdominal fat and lean tissues. The method may serve as a useful tool for evaluation and follow-up of various dietary and training programmes. PMID:23615566
An Examination of Ultrasound Measured Tissue Perfusion on Breast Cancer
1998-12-01
is similar to those of the study by Ivey et al. [9] in which high intensity fields were used to produce cavitation bubbles for ultrasound contrast...ft * * AD AWARD NUMBER DAMD17-94-J-4144 TITLE: ^ Examination of Ultrasound Measured Tissue Perfusion on Breast Cancer...Examination of Ultrasound Measured Tissue Perfusion on Breast Cancer 3. REPORT TYPE AND DATES COVERED Final (1 Jun 94 - 30 Nov 98) 5. FUNDING
Mistakes in ultrasound examination of salivary glands
Jakubowski, Wiesław
2016-01-01
Ultrasonography is the first imaging method applied in the case of diseases of the salivary glands. The article discusses basic mistakes that can be made during an ultrasound examination of these structures. The reasons for these mistakes may be examiner-dependent or may be beyond their control. The latter may include, inter alia, difficult conditions during examination (technical or patient-related), similarity of ultrasound images in different diseases, the lack of clinical and laboratory data as well as the lack of results of other examinations, their insufficient number or incorrectness. Doctor-related mistakes include: the lack of knowledge of normal anatomy, characteristics of ultrasound images in various salivary gland diseases and statistical incidence of diseases, but also attaching excessive importance to such statistical data. The complex anatomical structures of the floor of the oral cavity may be mistaken for benign or malignant tumors. Fragments of correct anatomical structures (bones, arterial wall fibrosis, air bubbles in the mouth) can be wrongly interpreted as deposits in the salivary gland or in its excretory duct. Correct lymph nodes in the parotid glands may be treated as pathologic structures. Lesions not being a simple cyst, e.g. lymphoma, benign or malignant tumors of the salivary glands or metastatic lymph nodes, can be mistaken for one. The image of disseminated focal changes, both anechoic and solid, is not pathognomonic for specific diseases in the salivary glands. However, in part, it occurs typically and requires an extended differential diagnosis. Small focal changes and infiltrative lesions pose a diagnostic problem because their etiology cannot be safely suggested on the basis of an ultrasound examination itself. The safest approach is to refer patients with abnormal focal changes for an ultrasoundguided fine-needle aspiration biopsy. PMID:27446603
Right Upper Quadrant Pain: Ultrasound First!
Revzin, Margarita V; Scoutt, Leslie M; Garner, Joseph G; Moore, Christopher L
2017-10-01
Acute right upper quadrant (RUQ) pain is a common presenting symptom in emergency departments and outpatient medical practices, and is most commonly attributable to biliary and hepatic pathology. Ultrasound should be used as a first-line imaging modality for the diagnosis of gallstones and cholecystitis, as it allows the differentiation of medical and surgical causes of upper abdominal pathology, and in many circumstances is sufficient to guide patient management. Knowledge of strengths and limitations of ultrasound in the evaluation of RUQ is paramount in correct diagnosis. A spectrum of RUQ pathology for which a RUQ ultrasound examination should reasonably be considered as the initial imaging modality of choice will be reviewed. © 2017 by the American Institute of Ultrasound in Medicine.
Ocular examination for trauma; clinical ultrasound aboard the International Space Station.
Chiao, Leroy; Sharipov, Salizhan; Sargsyan, Ashot E; Melton, Shannon; Hamilton, Douglas R; McFarlin, Kellie; Dulchavsky, Scott A
2005-05-01
Ultrasound imaging is a successful modality in a broad variety of diagnostic applications including trauma. Ultrasound has been shown to be accurate when performed by non-radiologist physicians; recent reports have suggested that non-physicians can perform limited ultrasound examinations. A multipurpose ultrasound system is installed on the International Space Station (ISS) as a component of the Human Research Facility (HRF). This report documents the first ocular ultrasound examination conducted in space, which demonstrated the capability to assess physiologic alterations or pathology including trauma during long-duration space flight. An ISS crewmember with minimal sonography training was remotely guided by an imaging expert from Mission Control Center (MCC) through a comprehensive ultrasound examination of the eye. A multipurpose ultrasound imager was used in conjunction with a space-to-ground video downlink and two-way audio. Reference cards with topological reference points, hardware controls, and target images were used to facilitate the examination. Multiple views of the eye structures were obtained through a closed eyelid. Pupillary response to light was demonstrated by modifying the light exposure of the contralateral eye. A crewmember on the ISS was able to complete a comprehensive ocular examination using B- and M-mode ultrasonography with remote guidance from an expert in the MCC. Multiple anteroposterior, oblique, and coronal views of the eye clearly demonstrated the anatomic structures of both segments of the globe. The iris and pupil were readily visualized with probe manipulation. Pupillary diameter was assessed in real time in B- and M-mode displays. The anatomic detail and fidelity of ultrasound video were excellent and could be used to answer a variety of clinical and space physiologic questions. A comprehensive, high-quality ultrasound examination of the eye was performed with a multipurpose imager aboard the ISS by a non-expert operator using
Ocular examination for trauma; clinical ultrasound aboard the International Space Station
NASA Technical Reports Server (NTRS)
Chiao, Leroy; Sharipov, Salizhan; Sargsyan, Ashot E.; Melton, Shannon; Hamilton, Douglas R.; McFarlin, Kellie; Dulchavsky, Scott A.
2005-01-01
BACKGROUND: Ultrasound imaging is a successful modality in a broad variety of diagnostic applications including trauma. Ultrasound has been shown to be accurate when performed by non-radiologist physicians; recent reports have suggested that non-physicians can perform limited ultrasound examinations. A multipurpose ultrasound system is installed on the International Space Station (ISS) as a component of the Human Research Facility (HRF). This report documents the first ocular ultrasound examination conducted in space, which demonstrated the capability to assess physiologic alterations or pathology including trauma during long-duration space flight. METHODS: An ISS crewmember with minimal sonography training was remotely guided by an imaging expert from Mission Control Center (MCC) through a comprehensive ultrasound examination of the eye. A multipurpose ultrasound imager was used in conjunction with a space-to-ground video downlink and two-way audio. Reference cards with topological reference points, hardware controls, and target images were used to facilitate the examination. Multiple views of the eye structures were obtained through a closed eyelid. Pupillary response to light was demonstrated by modifying the light exposure of the contralateral eye. RESULTS: A crewmember on the ISS was able to complete a comprehensive ocular examination using B- and M-mode ultrasonography with remote guidance from an expert in the MCC. Multiple anteroposterior, oblique, and coronal views of the eye clearly demonstrated the anatomic structures of both segments of the globe. The iris and pupil were readily visualized with probe manipulation. Pupillary diameter was assessed in real time in B- and M-mode displays. The anatomic detail and fidelity of ultrasound video were excellent and could be used to answer a variety of clinical and space physiologic questions. CONCLUSIONS: A comprehensive, high-quality ultrasound examination of the eye was performed with a multipurpose imager
Whittaker, Jackie L; Warner, Martin B; Stokes, Maria J
2010-08-01
Clinical use of ultrasound imaging by physiotherapists is increasing; however, the clinical setting may be problematic due to variability inherent in the environment. As transducer motion interferes with accurate measurement, this study aimed to measure handheld transducer motion, relative to the pelvis, during a clinical simulation involving typical maneuvers employed in a physiotherapy assessment of the lumbopelvic region. Transducer motion about three axes and through one plane was measured (Vicon, Oxford, UK) on 12 participants during three clinical maneuvers at four abdominal imaging sites. Data were grouped and means used to determine discrepancies in transducer and pelvic motion for each imaging site/maneuver combination. None of the conditions produced large transducer motions relative to the pelvis and all findings were within previously established guidelines for acceptable amounts of transducer motion. These findings suggest that an ultrasound transducer can be held relatively stationary in a clinical setting, for the maneuvers tested. Copyright 2010 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Kim, Jin Soo; Choi, Jong Bum; Lee, Sook Young; Kim, Wook Hwan; Baek, Nam Hyun; Kim, Jayoun; Park, Chu Kyung; Lee, Yeon Ju; Park, Sung Yong
2016-01-01
Abstract Background: Robotic cholecystectomy (RC) using port sites in the lower abdominal area (T12-L1) rather than the upper abdomen has recently been introduced as an alternative procedure for laparoscopic cholecystectomy. Therefore, we investigated the time course of different components of pain and the analgesic effect of the bilateral ultrasound-guided split injection technique for rectus sheath block (sRSB) after RC in female patients. Methods: We randomly assigned 40 patients to undergo ultrasound-guided sRSB (RSB group, n = 20) or to not undergo any block (control group, n = 20). Pain was subdivided into 3 components: superficial wound pain, deep abdominal pain, and referred shoulder pain, which were evaluated with a numeric rating scale (from 0 to 10) at baseline (time of awakening) and at 1, 6, 9, and 24 hours postoperatively. Consumption of fentanyl and general satisfaction were also evaluated 1 hour (before discharge from the postanesthesia care unit) and 24 hours postoperatively (end of study). Results: Superficial wound pain was predominant only at awakening, and after postoperative 1 hour in the control group. Bilateral ultrasound-guided sRSB significantly decreased superficial pain after RC (P < 0.01) and resulted in a better satisfaction score (P < 0.05) 1 hour after RC in the RSB group compared with the control group. The cumulative postoperative consumption of fentanyl at 6, 9, and 24 hours was not significantly different between groups. Conclusions: After RC with lower abdominal ports, superficial wound pain predominates over deep intra-abdominal pain and shoulder pain only at the time of awakening. Afterwards, superficial and deep pain decreased to insignificant levels in 6 hours. Bilateral ultrasound-guided sRSB was effective only during the first hour. This limited benefit should be balanced against the time and risks entailed in performing RSB. PMID:27495072
Chira, Romeo Ioan; Calauz, Adriana; Manole, Simona; Valean, Simona; Mircea, Petru Adrian
2017-03-01
Congenital extrahepatic portosystemic shunt (Abernethy malformation) is a rare condition characterized by developmental abnormalities of the portal venous system resulting in the diversion of the portal blood from the liver to the systemic venous system through a complete or partial shunt of the portomesenteric blood. We report the case of an 18 year-old female examined for abdominal pain, presenting cholestasis syndrome and an elevated serum aspartate aminotransferase level. Liver ultrasound examination revealed the absence of the portal vein with a complete extrahepatic shunt of the portal blood, multiple focal liver lesions, and multiple associated vascular anomalies. A surgical portosystemic shunt and a secondary portosystemic shunt due to portal vein thrombosis were excluded, enabling the diagnosis of a congenital portosystemic shunt. A complex investigation also discovered bone anomalies, and the liver biopsy of the dominant focal lesion revealed adenoma. On a short-term follow-up under hepatoprotective medication, the biochemical parameters improved mildly; however, the size of the main focal lesion increased. Congenital absence of the portal vein often remains an incidental diagnosis. In experienced hands, ultrasonography can diagnose it, but a comprehensive thoraco-abdominal evaluation is compulsory, considering the many potential associated anomalies. In these patients, development of adenomatous liver lesions secondary to Abernethy type Ib malformation represents an indication for liver transplantation.
Diagnostic utility of abdominal ultrasonography in dogs with chronic vomiting.
Leib, M S; Larson, M M; Panciera, D L; Troy, G C; Monroe, W E; Rossmeisl, J H; Forrester, S D; Herring, E S
2010-01-01
Chronic vomiting is a common problem in dogs that has many causes. Ultrasonographic descriptions of many gastrointestinal (GI) diseases have been published. However, diagnostic utility of ultrasonography in dogs with chronic vomiting has not been investigated. Diagnostic utility of abdominal ultrasound will be highest in dogs with GI neoplasia and lowest in those with inflammatory disorders. Eighty-nine pet dogs with chronic vomiting. Medical records were reviewed and the contribution of abdominal ultrasound to the clinical diagnosis was subjectively scored. In 68.5% of dogs, the reviewers thought that the same diagnosis would have been reached without performing ultrasonography. In 22.5% of dogs, the ultrasound examination was considered to be vital or beneficial to the diagnosis. Univariable analysis identified that increased diagnostic utility was associated with increasing age, a greater number of vomiting episodes per week, presence of weight loss, a greater percentage of lost body weight, and a final diagnosis of GI lymphoma or gastric adenocarcinoma. However, multivariate analysis only identified increasing age and a final diagnosis of gastric adenocarcinoma or GI lymphoma to be associated with increased diagnostic utility. In 12.4% of dogs, additional benefits of ultrasonography to case management, excluding the contribution to the vomiting problem, were identified. The diagnostic utility of abdominal ultrasonography was high in 27% of dogs. The presence of factors that are associated with high diagnostic utility is an indication to perform abdominal ultrasonography in dogs with chronic vomiting.
Gasanova, Irina; Grant, Erica; Way, Megan; Rosero, Eric B; Joshi, Girish P
2013-07-01
Transversus abdominis plane (TAP) block has been shown to provide pain relief after abdominal procedures. However, TAP block combined with multimodal analgesia technique have not been assessed in a randomized controlled trial. This randomized, controlled, observer-blinded study was designed to evaluate the analgesic efficacy of bilateral ultrasound-guided TAP blocks with or without acetaminophen and non-steroidal anti-inflammatory drug (NSAID) combination. Patients undergoing total abdominal hysterectomy were randomized to one of three groups. Group 1 (n = 25) received a TAP block and ketorolac 30 mg, IV at the end of surgery and then ketorolac plus paracetamol 650 mg, orally, every 6 h for 24 h. Group 2 (n = 24) received only TAP block at the end of surgery. Group 3 (n = 25) received ketorolac 30 mg, IV at the end of surgery and then ketorolac plus paracetamol 650 mg, orally, every 6 h for 24 h. All patients received IV-PCA morphine for 24-h, postoperatively. All patients received a standardized general anaesthetic technique and dexamethasone 4 mg and ondansetron 4 mg, IV for antiemetic prophylaxis. There were no statistically significant differences in pain at rest between the groups. However, the pain on coughing (dynamic pain) in Group 1 was significantly less variable, compared with the other two groups (P = 0.012). Opioid consumption and occurrences of nausea, vomiting, and rescue antiemetic were similar in three the groups. The combination of TAP block and acetaminophen and NSAID provided less variability in dynamic pain compared with either treatment alone.
Measurement of superficial and deep abdominal muscle thickness: an ultrasonography study.
Tahan, Nahid; Khademi-Kalantari, Khosro; Mohseni-Bandpei, Mohammad Ali; Mikaili, Saeed; Baghban, Alireza Akbarzadeh; Jaberzadeh, Shapour
2016-08-23
Real-time ultrasound imaging is a valid method in the field of rehabilitation. The ultrasound imaging allows direct visualization for real-time study of the muscles as they contract over the time. Measuring of the size of each abdominal muscle in relation to the others provides useful information about the differences in structure, as well as data on trunk muscle activation patterns. The purpose of this study was to assess the size and symmetry of the abdominal muscles at rest in healthy adults and to provide a reference range of absolute abdominal muscle size in a relatively large population. A total 156 healthy subjects with the age range of 18-44 years were randomly recruited. The thickness of internal oblique, external oblique, transverse abdominis, and rectus abdominis muscles was measured at rest on both right and left sides using ultrasound. Independent t test was used to compare the mean thickness of each abdominal muscle between males and females. Differences on side-to-side thicknesses were assessed using paired t test. The association between abdominal muscle thicknesses with gender and anthropometric variables was examined using the Pearson correlation coefficient. A normal pattern of increasing order of mean abdominal muscle thickness was found in both genders at both right and left sides: transverse abdominis < external oblique < internal oblique < rectus abdominis. There was a significant difference on the size of transverse abdominis, internal oblique, and external oblique muscles between right and left sides in both genders. Males had significantly thicker abdominal muscles than females. Age was significantly correlated with the thickness of internal oblique, external oblique, and rectus abdominis muscles. Body mass index was also positively correlated with muscle thickness of rectus abdominis and external oblique. The results provide a normal reference range for the abdominal muscles in healthy subjects and may be used as an index to
Segmentation of images of abdominal organs.
Wu, Jie; Kamath, Markad V; Noseworthy, Michael D; Boylan, Colm; Poehlman, Skip
2008-01-01
Abdominal organ segmentation, which is, the delineation of organ areas in the abdomen, plays an important role in the process of radiological evaluation. Attempts to automate segmentation of abdominal organs will aid radiologists who are required to view thousands of images daily. This review outlines the current state-of-the-art semi-automated and automated methods used to segment abdominal organ regions from computed tomography (CT), magnetic resonance imaging (MEI), and ultrasound images. Segmentation methods generally fall into three categories: pixel based, region based and boundary tracing. While pixel-based methods classify each individual pixel, region-based methods identify regions with similar properties. Boundary tracing is accomplished by a model of the image boundary. This paper evaluates the effectiveness of the above algorithms with an emphasis on their advantages and disadvantages for abdominal organ segmentation. Several evaluation metrics that compare machine-based segmentation with that of an expert (radiologist) are identified and examined. Finally, features based on intensity as well as the texture of a small region around a pixel are explored. This review concludes with a discussion of possible future trends for abdominal organ segmentation.
Abdominal Wall Desmoid during Pregnancy: Diagnostic Challenges
Awwad, Johnny; Hammoud, Nadine; Farra, Chantal; Fares, Farah; Abi Saad, George; Ghazeeri, Ghina
2013-01-01
Background. Desmoids are benign tumors, with local invasive features and no metastatic potential, which have rarely been described to be pregnancy associated. Case. We described the rapid growth of an anterior abdominal wall mass in a 40-year-old pregnant woman. Due to its close proximity to the enlarged uterus, it was misdiagnosed to be a uterine leiomyoma by ultrasound examination. Final tissue diagnosis and radical resection were done at the time of abdominal delivery. Conclusion. Due to the diagnostic limitations of imaging techniques, desmoids should always be considered when the following manifestations are observed in combination: progressive growth of a solitary abdominal wall mass during pregnancy and well-delineated smooth tumor margins demonstrated by imaging techniques. This case emphasizes the importance of entertaining uncommon medical conditions in the differential diagnosis of seemingly common clinical manifestations. PMID:23346436
An orthopedist's guide to shoulder ultrasound: a systematic review of examination protocols.
Amoo-Achampong, Kelms; Nwachukwu, Benedict U; McCormick, Frank
2016-11-01
The utilization of musculoskeletal ultrasound has expanded within the setting of the orthopedic clinic as a cost-effective, point-of-care diagnostic tool for shoulder pathology. In experienced hands, ultrasound exhibits capabilities equivalent to that of magnetic resonance imaging in the diagnosis of many shoulder diseases including full-thickness and partial-thickness rotator cuff tears. Although similarly effective in identifying additional shoulder disease processes, major obstacles to its widespread use include user dependence and intrinsic limitation to extra-articular diagnosis. The purpose of this review is to present a step-by-step guide of how to perform a comprehensive shoulder examination and to discuss the appropriate use, economic benefit and implementation of ultrasound within the clinic. A systematic search (June 2016) of PubMed, Scopus, and EMBASE databases was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for literature presenting shoulder ultrasound examination protocols. Included studies were peer-reviewed articles or academic society endorsed protocols presenting comprehensive sonographic examinations of the adult shoulder. Papers with limited or single structure examination descriptions, non-English language, and publication dates before 1980 were excluded. Final papers meeting criteria were secondarily screened for publication after 2005 to reflect the current state of ultrasound imaging. The search yielded 1,725 unique articles with 17 studies meeting final selection criteria. Information from identified studies was summarized to formulate a 4-part shoulder examination protocol, including steps most pertinent to orthopedic in-office diagnoses. In agreement with previous studies, the inexperienced orthopedic surgeon can be quickly trained to expert level proficiency in shoulder ultrasound diagnosis. Using an established protocol, a comprehensive, yet effective shoulder
Ultrasound detection of placenta accreta in the first trimester of pregnancy.
Rahimi-Sharbaf, Fatemeh; Jamal, Ashraf; Mesdaghinia, Elaheh; Abedzadeh-Kalahroudi, Masoumeh; Niroomanesh, Shirin; Atoof, Fatemeh
2014-06-01
Placenta accreta is considered a life-threatening condition and the main cause of maternal mortality. Prenatal diagnosis of placenta accreta usually is made by clinical presentation, imaging studies like ultrasound and MRI in the second and third trimester. To determine accuracy of ultrasound findings for placenta accreta in the first trimester of pregnancy. In a longitudinal study 323 high risk patients for placenta accreta were assessed. The eligible women were examined by vaginal and abdominal ultrasound for gestational sac and placental localization and they were followed up until the end of pregnancy. The ultrasound findings were compared with histopathological examinations as a gold standard. The sensitivity, specificity, positive and negative predictive value of ultrasound were estimated for the first trimester and compared with other 2 trimesters in the case of repeated ultrasound examination. Ultrasound examinations in the first trimester revealed that 28 cases had the findings in favor of placenta accreta which ultimately was confirmed in 7 cases. The ultrasound sensitivity and specificity for detecting placenta accreta in the first trimester was 41% [95% CI: 16.2-62.7] and 88% [95% CI: 88.2-94.6] respectively. Ultrasound screening for placenta accreta in the first trimester of pregnancy could not achieve the high sensitivity as second and third trimester of pregnancy.
Ultrasound: Abdomen (For Parents)
... the computer screen. A technician (sonographer) trained in ultrasound imaging will spread a clear, warm gel on the skin of the abdomen. This gel helps with the transmission of the sound waves. The ... abdominal ultrasound is painless. Your child may feel a slight ...
Henry, Sharon M; Westervelt, Karen C
2005-06-01
Randomized controlled trial. To determine if supplementing typical clinical instruction with real-time ultrasound feedback facilitates performance and retention of the abdominal hollowing exercise (AHE). Increasingly clinicians are using real-time ultrasound imaging as a form of feedback when teaching patients trunk stabilization exercises; however, there has been no justification for this practice. Forty-eight subjects were divided randomly into 3 groups that received different types of feedback: group 1 received minimal verbal feedback, group 2 received verbal and palpatory feedback, and group 3 received real-time ultrasound, verbal, and palpatory feedback. If the subject performed 3 consecutive correct AHEs during the initial session, she/he returned for a retention test. The performance of 3 consecutive, correct AHEs was the criterion measure; the number of trials to criterion was also recorded during the initial and retention test sessions. The ability to perform the AHE differed among groups (P<.001). During the initial session, 12.5% of subjects in group 1, 50.0% of subjects in group 2, and 87.5% of subjects in group 3 were able to perform 3 consecutive AHEs. Group 3 subjects achieved the criterion in fewer trials than the other 2 groups (P = .0006). No differences among groups were found for the retention testing; however, low power due to fewer subjects precluded a strong interpretation of this finding. Real-time ultrasound feedback can decrease the number of trials needed to consistently perform the AHE; however, the data are inconclusive with regard to retention of this skill.
Does this adult patient have a blunt intra-abdominal injury?
Nishijima, Daniel K; Simel, David L; Wisner, David H; Holmes, James F
2012-04-11
Blunt abdominal trauma often presents a substantial diagnostic challenge. Well-informed clinical examination can identify patients who require further diagnostic evaluation for intra-abdominal injuries after blunt abdominal trauma. To systematically assess the precision and accuracy of symptoms, signs, laboratory tests, and bedside imaging studies to identify intra-abdominal injuries in patients with blunt abdominal trauma. We conducted a structured search of MEDLINE (1950-January 2012) and EMBASE (1980-January 2012) to identify English-language studies examining the identification of intra-abdominal injuries. A separate, structured search was conducted for studies evaluating bedside ultrasonography. We included studies of diagnostic accuracy for intra-abdominal injury that compared at least 1 finding with a reference standard of abdominal computed tomography, diagnostic peritoneal lavage, laparotomy, autopsy, and/or clinical course for intra-abdominal injury. Twelve studies on clinical findings and 22 studies on bedside ultrasonography met inclusion criteria for data extraction. Critical appraisal and data extraction were independently performed by 2 authors. The prevalence of intra-abdominal injury in adult emergency department patients with blunt abdominal trauma among all evidence level 1 and 2 studies was 13% (95% CI, 10%-17%), with 4.7% (95% CI, 2.5%-8.6%) requiring therapeutic surgery or angiographic embolization of injuries. The presence of a seat belt sign (likelihood ratio [LR] range, 5.6-9.9), rebound tenderness (LR, 6.5; 95% CI, 1.8-24), hypotension (LR, 5.2; 95% CI, 3.5-7.5), abdominal distention (LR, 3.8; 95% CI, 1.9-7.6), or guarding (LR, 3.7; 95% CI, 2.3-5.9) suggest an intra-abdominal injury. The absence of abdominal tenderness to palpation does not rule out an intra-abdominal injury (summary LR, 0.61; 95% CI, 0.46-0.80). The presence of intraperitoneal fluid or organ injury on bedside ultrasound assessment is more accurate than any history and
Standards of ultrasound imaging of the adrenal glands
Jakubowski, Wiesław S.; Dobruch-Sobczak, Katarzyna; Kasperlik-Załuska, Anna A.
2015-01-01
Adrenal glands are paired endocrine glands located over the upper renal poles. Adrenal pathologies have various clinical presentations. They can coexist with the hyperfunction of individual cortical zones or the medulla, insufficiency of the adrenal cortex or retained normal hormonal function. The most common adrenal masses are tumors incidentally detected in imaging examinations (ultrasound, tomography, magnetic resonance imaging), referred to as incidentalomas. They include a range of histopathological entities but cortical adenomas without hormonal hyperfunction are the most common. Each abdominal ultrasound scan of a child or adult should include the assessment of the suprarenal areas. If a previously non-reported, incidental solid focal lesion exceeding 1 cm (incidentaloma) is detected in the suprarenal area, computed tomography or magnetic resonance imaging should be conducted to confirm its presence and for differentiation and the tumor functional status should be determined. Ultrasound imaging is also used to monitor adrenal incidentaloma that is not eligible for a surgery. The paper presents recommendations concerning the performance and assessment of ultrasound examinations of the adrenal glands and their pathological lesions. The article includes new ultrasound techniques, such as tissue harmonic imaging, spatial compound imaging, three-dimensional ultrasound, elastography, contrast-enhanced ultrasound and parametric imaging. The guidelines presented above are consistent with the recommendations of the Polish Ultrasound Society. PMID:26807295
Segura-Grau, A; Sáez-Fernández, A; Rodríguez-Lorenzo, A; Díaz-Rodríguez, N
2014-01-01
Ultrasound is a non-invasive, accessible, and versatile diagnostic technique that uses high frequency ultrasound waves to define outline the organs of the human body, with no ionising radiation, in real time and with the capacity to visual several planes. The high diagnostic yield of the technique, together with its ease of uses plus the previously mentioned characteristics, has currently made it a routine method in daily medical practice. It is for this reason that the multidisciplinary character of this technique is being strengthened every day. To be able to perform the technique correctly requires knowledge of the physical basis of ultrasound, the method and the equipment, as well as of the human anatomy, in order to have the maximum information possible to avoid diagnostic errors due to poor interpretation or lack of information. Copyright © 2013 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.
[Diagnostic imaging and acute abdominal pain].
Liljekvist, Mads Svane; Pommergaard, Hans-Christian; Burcharth, Jakob; Rosenberg, Jacob
2015-01-19
Acute abdominal pain is a common clinical condition. Clinical signs and symptoms can be difficult to interpret, and diagnostic imaging may help to identify intra-abdominal disease. Conventional X-ray, ultrasound (US) and computed tomography (CT) of the abdomen vary in usability between common surgical causes of acute abdominal pain. Overall, conventional X-ray cannot confidently diagnose or rule out disease. US and CT are equally trustworthy for most diseases. US with subsequent CT may enhance diagnostic precision. Magnetic resonance seems promising for future use in acute abdominal imaging.
Wei, L C; Gong, G Y; Chen, J H; Hou, P Y; Li, Q Y; Zheng, Z Y; Su, Y M; Zheng, Y; Luo, C Z; Zhang, K; Xu, T F; Ye, Y H; Lan, Y J; Wei, X M
2018-03-27
Objective: To discuss the feasibility, effect and safety of lower abdominal aorta balloon occlusion technique by ultrasound guiding during caesarean section in patients with pernicious placenta previa. Methods: The clinical data of 40 patients with pernicious placenta previa complicated with placenta accreta from January 2015 to August 2017 in Liuzhou workers hospital were analyzed retrospectively. The study group included 20 cases, which were operated in the way of cesarean section combined lower abdominal aorta balloon occlusion technique by ultrasound guiding, while the control group also included 20 cases, which were operated in the way of the conventional cesarean section without balloon occlusion technique. The bleeding amount, blood transfusion volume, operative total time, hysterectomy and complications of the two groups were compared. Results: The bleeding amount and blood transfusion volume in study group were(850±100)ml and (400±50)ml, which were lower than that of the control group[(2 500±230)ml and (1 500±100)ml], the difference was statistically significant( t =35.624, 16.523, all P <0.05). In addition, the hysterectomy rate in study group was 5%, which was lower than that in the control group(30%), the difference was statistically significant(χ 2 =8.672, P <0.05). And the total time of operation was (2.0±0.5)h in the study group, which was shorter than that in the control group[(3.5±0.4)h]. The difference was statistically significant( t =11.362, P <0.05). No postoperative complications took place in the study group.The blood pressure, heart rate and blood oxygen fluctuated significantly, and the postoperative renal function was significantly reduced in the control group. Conclusions: The lower abdominal aorta balloon occlusion technique by ultrasound guiding during a caesarean section in patients with pernicious placenta previa can effectively control the bleeding during operation, and preserve reproductive function to the utmost degree
Christian, Nicole Townsend; Burlew, Clay Cothren; Moore, Ernest E; Geddes, Andrea E; Wagenaar, Amy E; Fox, Charles J; Pieracci, Fredric M
2018-06-01
The focused abdominal sonography for trauma (FAST) examination has been reported to be unreliable in pelvic fracture patients. Additionally, given the advent of new therapeutic interventions, such as resuscitative endovascular balloon occlusion of the aorta (REBOA), rapid identification of intra-abdominal hemorrhage compared with Zone III hemorrhage may guide different therapeutic strategies. We hypothesized that FAST is reliable for detecting clinically significant intra-abdominal hemorrhage in the face of complex pelvic fractures. Our pelvic fracture database of all hemodynamically unstable patients requiring intervention from January 1, 2005, to July 1, 2015, was reviewed. The FAST examination was compared with operative and computed tomography (CT) scan findings. Confirmatory evaluation for FAST(-) patients was considered positive if therapeutic intervention was required. During the study period, 81 patients in refractory shock with FAST imaging in our emergency department (ED) underwent pelvic packing. Mean age was 45 ± 2 years and Injury Severity Score was 50 ± 1.5. The FAST examination was negative in 53 patients; 52 patients did not require operative intervention for abdominal bleeding while one patient required splenectomy. The FAST examination was positive in 28 patients; 26 had findings confirmed by CT or laparotomy while two patients did not have intra-abdominal hemorrhage on further evaluation. The sensitivity and specificity for FAST in this population was 96% and 96%, respectively, positive predictive value was 93%, and negative predictive value was 98%. The false-negative and -positive rates for FAST were 2% and 7%. Focused abdominal sonography for trauma examination reliably identifies clinically significant hemoperitoneum in life-threatening, pelvic fracture related hemorrhage. The incidence of a false-negative FAST in this unstable pelvic fracture population was 2%. FAST results may be used when determining the role of REBOA in these
Chaves, Gabriela Villaça; Pereira, Sílvia Elaine; Saboya, Carlos José; Cortes, Caroline; Ramalho, Rejane
2009-01-01
To evaluate the concordance between abdominal ultrasound and an MRI (Magnetic Resonance Imaging) in the diagnosis of non-alcoholic fatty liver disease (NAFLD), and concordance of these two methods with the histopathological exam. The population studied was comprised of 145 patients with morbid obesity (BMI > or = 40 Kg/m(2)), of both genders. NAFLD diagnosis was performed by MRI and Ultrasound. Liver biopsy was performed in a sub-sample (n=40). To evaluate the concordance of these two methods, the kappa coefficient was used. Concordance between both methods (MRI and Ultrasound) was poor and not significant (Kappa adjusted= 0.27; CI 95%= 0.07-0.39.) Nevertheless a slight concordance was found between diagnosis of NAFLD by ultrasound and the hepatic biopsy, with 83.,3% of concordant results and Kappa adjusted= 0.67.Results of an MRI and the histopathological exam were compared and results showed 53.6% of concordant results and kappa adjusted= 0.07. The concordance found in the diagnosis performed using the ultrasound method and the hepatic biopsy, shows a need to implement and perform more research on the use of ultrasound to validate and reconsider these methods. This would minimize the need to perform biopsies to detect and diagnose such disease.
Ultrasound Imaging System Video
NASA Technical Reports Server (NTRS)
2002-01-01
In this video, astronaut Peggy Whitson uses the Human Research Facility (HRF) Ultrasound Imaging System in the Destiny Laboratory of the International Space Station (ISS) to image her own heart. The Ultrasound Imaging System provides three-dimension image enlargement of the heart and other organs, muscles, and blood vessels. It is capable of high resolution imaging in a wide range of applications, both research and diagnostic, such as Echocardiography (ultrasound of the heart), abdominal, vascular, gynecological, muscle, tendon, and transcranial ultrasound.
Kim, Jin Soo; Choi, Jong Bum; Lee, Sook Young; Kim, Wook Hwan; Baek, Nam Hyun; Kim, Jayoun; Park, Chu Kyung; Lee, Yeon Ju; Park, Sung Yong
2016-08-01
Robotic cholecystectomy (RC) using port sites in the lower abdominal area (T12-L1) rather than the upper abdomen has recently been introduced as an alternative procedure for laparoscopic cholecystectomy. Therefore, we investigated the time course of different components of pain and the analgesic effect of the bilateral ultrasound-guided split injection technique for rectus sheath block (sRSB) after RC in female patients. We randomly assigned 40 patients to undergo ultrasound-guided sRSB (RSB group, n = 20) or to not undergo any block (control group, n = 20). Pain was subdivided into 3 components: superficial wound pain, deep abdominal pain, and referred shoulder pain, which were evaluated with a numeric rating scale (from 0 to 10) at baseline (time of awakening) and at 1, 6, 9, and 24 hours postoperatively. Consumption of fentanyl and general satisfaction were also evaluated 1 hour (before discharge from the postanesthesia care unit) and 24 hours postoperatively (end of study). Superficial wound pain was predominant only at awakening, and after postoperative 1 hour in the control group. Bilateral ultrasound-guided sRSB significantly decreased superficial pain after RC (P < 0.01) and resulted in a better satisfaction score (P < 0.05) 1 hour after RC in the RSB group compared with the control group. The cumulative postoperative consumption of fentanyl at 6, 9, and 24 hours was not significantly different between groups. After RC with lower abdominal ports, superficial wound pain predominates over deep intra-abdominal pain and shoulder pain only at the time of awakening. Afterwards, superficial and deep pain decreased to insignificant levels in 6 hours. Bilateral ultrasound-guided sRSB was effective only during the first hour. This limited benefit should be balanced against the time and risks entailed in performing RSB.
Ultrasound detection of placenta accreta in the first trimester of pregnancy
Rahimi-Sharbaf, Fatemeh; Jamal, Ashraf; Mesdaghinia, Elaheh; Abedzadeh- Kalahroudi, Masoumeh; Niroomanesh, Shirin; Atoof, Fatemeh
2014-01-01
Background: Placenta accreta is considered a life-threatening condition and the main cause of maternal mortality. Prenatal diagnosis of placenta accreta usually is made by clinical presentation, imaging studies like ultrasound and MRI in the second and third trimester. Objective: To determine accuracy of ultrasound findings for placenta accreta in the first trimester of pregnancy. Materials and Methods: In a longitudinal study 323 high risk patients for placenta accreta were assessed. The eligible women were examined by vaginal and abdominal ultrasound for gestational sac and placental localization and they were followed up until the end of pregnancy. The ultrasound findings were compared with histopathological examinations as a gold standard. The sensitivity, specificity, positive and negative predictive value of ultrasound were estimated for the first trimester and compared with other 2 trimesters in the case of repeated ultrasound examination. Results: Ultrasound examinations in the first trimester revealed that 28 cases had the findings in favor of placenta accreta which ultimately was confirmed in 7 cases. The ultrasound sensitivity and specificity for detecting placenta accreta in the first trimester was 41% [95% CI: 16.2-62.7] and 88% [95% CI: 88.2-94.6] respectively. Conclusion: Ultrasound screening for placenta accreta in the first trimester of pregnancy could not achieve the high sensitivity as second and third trimester of pregnancy. PMID:25071851
[Ultrasound screening of abdominal aortic aneurysm: Lessons from Vesale 2013].
Laroche, J P; Becker, F; Baud, J M; Miserey, G; Jaussent, A; Picot, M C; Bura-Rivière, A; Quéré, I
2015-12-01
Although aneurysm of the abdominal infra-renal aorta (AAA) meets criteria warranting B mode ultrasound screening, the advantages of mass screening versus selective targeted opportunistic screening remain a subject of debate. In France, the French Society of Vascular Medicine (SFMV) and the Health Authority (HAS) published recommendations for targeted opportunistic screening in 2006 and 2013 respectively. The SFMV held a mainstream communication day on November 21, 2013 in France involving participants from metropolitan France and overseas departments that led to a proposal for free AAA ultrasound screening: the Vesalius operation. Being a consumer operation, the selection criteria were limited to age (men and women between 60 and 75 years); the age limit was lowered to 50 years in case of direct family history of AAA. More than 7000 people (as many women as men) were screened in 83 centers with a 1.70% prevalence of AAA in the age-based target population (3.12% for men, 0.27% for women). The median diameter of detected AAA was 33 mm (range 20 to 74 mm). The prevalence of AAA was 1.7% in this population. Vesalius data are consistent with those of the literature both in terms of prevalence and for cardiovascular risk factors with the important role of smoking. Lessons from Vesalius to take into consideration are: screening is warranted in men 60 years and over, especially smokers, and in female smokers. Screening beyond 75 years should be discussed. Given the importance of screening, the SFMV set up a year of national screening for AAA (Vesalius operation 2014/2015) in order to increase public and physician awareness about AAA detection, therapeutic management, and monitoring. AAA is a serious, common, disease that kills 6000 people each year. The goal of screening is cost-effective reduction in the death toll. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Fatty liver disease in severe obese patients: Diagnostic value of abdominal ultrasound
de Moura Almeida, Alessandro; Cotrim, Helma Pinchemel; Barbosa, Daniel Batista Valente; de Athayde, Luciana Gordilho Matteoni; Santos, Adimeia Souza; Bitencourt, Almir Galvão Vieira; de Freitas, Luiz Antonio Rodrigues; Rios, Adriano; Alves, Erivaldo
2008-01-01
AIM: To evaluate the sensitivity and specificity of abdominal ultrasound (US) for the diagnosis of hepatic steatosis in severe obese subjects and its relation to histological grade of steatosis. METHODS: A consecutive series of obese patients, who underwent bariatric surgery from October 2004 to May 2005, was selected. Ultrasonography was performed in all patients as part of routine preoperative time and an intraoperative wedge biopsy was obtained at the beginning of the bariatric surgery. The US and histological findings of steatosis were compared, considering histology as the gold standard. RESULTS: The study included 105 patients. The mean age was 37.2 ± 10.6 years and 75.2% were female. The histological prevalence of steatosis was 89.5%. The sensitivity and specificity of US in the diagnosis of hepatic steatosis were, respectively, 64.9% (95% CI: 54.9-74.3) and 90.9% (95% CI: 57.1-99.5). The positive predictive value and negative predictive value were, respectively, 98.4% (95% CI: 90.2-99.9) and 23.3% (95% CI: 12.3-39.0). The presence of steatosis on US was associated to advanced grades of steatosis on histology (P = 0.016). CONCLUSION: Preoperative abdominal US in our series has not shown to be an accurate method for the diagnosis of hepatic steatosis in severe obese patients. Until another non-invasive method demonstrates better sensitivity and specificity values, histological evaluation may be recommended to these patients undergoing bariatric surgery. PMID:18322958
US Emergency Department Trends in Imaging for Pediatric Nontraumatic Abdominal Pain.
Niles, Lauren M; Goyal, Monika K; Badolato, Gia M; Chamberlain, James M; Cohen, Joanna S
2017-10-01
To describe national emergency department (ED) trends in computed tomography (CT) and ultrasound imaging for the evaluation of pediatric nontraumatic abdominal pain from 2007 through 2014. We used data from the National Hospital Ambulatory Medical Care Survey to measure trends in CT and ultrasound use among children with nontraumatic abdominal pain. We performed multivariable logistic regression to measure the strength of the association of ED type (pediatric versus general ED) with CT and ultrasound use adjusting for potential confounding variables. Of an estimated 21.1 million ED visits for nontraumatic abdominal pain, 14.6% (95% confidence interval [CI], 13.2%-16.0%) had CT imaging only, 10.9% (95% CI, 9.7%-12.1%) had ultrasound imaging only, and 1.9% (95% CI, 1.4%-2.4%) received both CT and ultrasound. The overall use of CT and ultrasound did not significantly change over the study period ( P trend .63 and .90, respectively). CT use was lower among children treated in pediatric EDs compared with general EDs (adjusted odds ratio 0.34; 95% CI, 0.17-0.69). Conversely, ultrasound use was higher among children treated in pediatric EDs compared with general EDs (adjusted odds ratio 2.14; 95% CI, 1.29-3.55). CT imaging for pediatric patients with nontraumatic abdominal pain has plateaued since 2007 after the steady increase seen in the preceding 9 years. Among this population, an increased likelihood of CT imaging was demonstrated in general EDs compared with pediatric EDs, in which there was a higher likelihood of ultrasound imaging. Dissemination of pediatric-focused radiology protocols to general EDs may help optimize radiation exposure in children. Copyright © 2017 by the American Academy of Pediatrics.
Seeing Is Believing: Evaluating a Point-of-Care Ultrasound Curriculum for 1st-Year Medical Students.
Nelson, Bret P; Hojsak, Joanne; Dei Rossi, Elizabeth; Karani, Reena; Narula, Jagat
2017-01-01
Point-of-care ultrasound has been a novel addition to undergraduate medical education at a few medical schools. The impact is not fully understood, and few rigorous assessments of educational outcomes exist. This study assessed the impact of a point-of-care ultrasound curriculum on image acquisition, interpretation, and student and faculty perceptions of the course. All 142 first-year medical students completed a curriculum on ultrasound physics and instrumentation, cardiac, thoracic, and abdominal imaging. A flipped classroom model of preclass tutorials and tests augmenting live, hands-on scanning sessions was incorporated into the physical examination course. Students and faculty completed surveys on impressions of the curriculum, and all students under-went competency assessments with standardized patients. The curriculum was a mandatory part of the physical examination course and was taught by experienced clinician-sonographers as well as faculty who do not routinely perform sonography in their clinical practice. Students and faculty agreed that the physical examination course was the right time to introduce ultrasound (87% and 80%). Students demonstrated proper use of the ultrasound machine functions (M score = 91.55), and cardiac, thoracic, and abdominal system assessments (M score = 80.35, 79.58, and 71.57, respectively). Students and faculty valued the curriculum, and students demonstrated basic competency in performance and interpretation of ultrasound. Further study is needed to determine how to best incorporate this emerging technology into a robust learning experience for medical students.
Thompson, Michelle B; Ramirez, Jonathan C; De La Rosa, Lisa M; Wood, Adam S; Desai, Shiv; Arjunan, Ananth; Song, Juhee; Erickson, Richard A
2015-02-01
To explore the utility of endoscopic ultrasound (EUS) in the evaluation of chronic upper abdominal pain (UAP) of undetermined etiology. Chronic UAP is a common problem with a challenging diagnosis and management. The role of EUS in the diagnosis of UAP may minimize additional testing; however, few studies describe the percentage of new diagnoses yielded in these patients. We conducted a retrospective analysis by reviewing electronic medical records at Scott and White Memorial Hospital, Texas A&M Health Sciences Center for patients with abdominal pain for ≥ 12 months not explained by previous workup referred for EUS for chronic UAP from January 1, 1998 through October 1, 2007. Patients with previous EUS in past 12 months were excluded from the study. Patient demographic data and imaging performed 6 months before and 24 months after EUS were reviewed and results documented. EUS was successful at diagnosing a new clinical etiology of chronic UAP in 33 patients (8.89%) with previous workup that was unrevealing for a definitive diagnosis. The most frequent diagnoses included pancreaticobiliary tree abnormalities, chronic pancreatitis, and fatty liver disease. Our results support the fact that the majority of patients UAP with prior imaging will have no identifiable organic etiology found on EUS to explain their pain; however, we suggest that EUS be considered in patients with suspected pancreatic or biliary pathology.
Evaluation Experiment of Ultrasound Computed Tomography for the Abdominal Sound Speed Imaging
NASA Astrophysics Data System (ADS)
Nogami, Keisuke; Yamada, Akira
2007-07-01
Abdominal sound speed tomographic imaging using through-transmission travel time data on the body surface was investigated. To this end, a hundred kHz range low-frequency wave was used to reduce the wave attenuation within an inner body medium. A method was investigated for the reconstruction of the image with the smallest possible number of path data around the abdominal surface. Specifically, the data from a strong scattering spinal cord should be avoided. To fulfill the requirement, the smoothed path algebraic reconstruction technique was introduced. The validity of this method was examined both on the numerically synthesized data and the experimentally measured data for the phantom specimen and actual human subject. It was shown that an abdominal tomographic sound speed image could be successfully obtained by preparing only 32 transducer locations at the circumference around the abdominal surface and their combination of less than 100 number of observation path data as well as by avoiding the data intersecting the spinal cord. In addition, fat regions were extracted having a sound speed lower than the threshold value to demonstrate the possibility of this method for metabolic syndrome diagnosis.
Kliper, Yael; Ben-Ami, Moshe; Perlitz, Yuri
2014-01-01
The aim of this study was to assess the effect of mild pressure applied on the abdominal wall by the ultrasound transducer on fetal cephalic indices. We examined by ultrasound 60 fetuses of healthy women, at 20-24 weeks of pregnancy, during routine prenatal evaluation. For every fetus biparietal diameter and head circumference were measured, with and without applying mild pressure by the ultrasound transducer. The weight and gestational age (GA) were calculated. The pressure applied by the transducer had a significant effect on the cephalic indices and on the weight and GA evaluations (p < 0.001). Fetal positioning significantly affected the impact that applied pressure had on head circumference and on the weight evaluation derived from it (p < 0.05). Applied pressure by an abdominal ultrasound probe affects cephalic indices and the derived weight and GA estimations. This may lead to incorrect diagnoses or hide pathological findings. The effect of applied pressure depends on fetal positioning. The examiner must be aware of this effect when evaluating the results of the measurements.
Standard plane localization in ultrasound by radial component model and selective search.
Ni, Dong; Yang, Xin; Chen, Xin; Chin, Chien-Ting; Chen, Siping; Heng, Pheng Ann; Li, Shengli; Qin, Jing; Wang, Tianfu
2014-11-01
Acquisition of the standard plane is crucial for medical ultrasound diagnosis. However, this process requires substantial experience and a thorough knowledge of human anatomy. Therefore it is very challenging for novices and even time consuming for experienced examiners. We proposed a hierarchical, supervised learning framework for automatically detecting the standard plane from consecutive 2-D ultrasound images. We tested this technique by developing a system that localizes the fetal abdominal standard plane from ultrasound video by detecting three key anatomical structures: the stomach bubble, umbilical vein and spine. We first proposed a novel radial component-based model to describe the geometric constraints of these key anatomical structures. We then introduced a novel selective search method which exploits the vessel probability algorithm to produce probable locations for the spine and umbilical vein. Next, using component classifiers trained by random forests, we detected the key anatomical structures at their probable locations within the regions constrained by the radial component-based model. Finally, a second-level classifier combined the results from the component detection to identify an ultrasound image as either a "fetal abdominal standard plane" or a "non- fetal abdominal standard plane." Experimental results on 223 fetal abdomen videos showed that the detection accuracy of our method was as high as 85.6% and significantly outperformed both the full abdomen and the separate anatomy detection methods without geometric constraints. The experimental results demonstrated that our system shows great promise for application to clinical practice. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Point-of-care cardiac ultrasound techniques in the physical examination: better at the bedside.
Kimura, Bruce J
2017-07-01
The development of hand-carried, battery-powered ultrasound devices has created a new practice in ultrasound diagnostic imaging, called 'point-of-care' ultrasound (POCUS). Capitalising on device portability, POCUS is marked by brief and limited ultrasound imaging performed by the physician at the bedside to increase diagnostic accuracy and expediency. The natural evolution of POCUS techniques in general medicine, particularly with pocket-sized devices, may be in the development of a basic ultrasound examination similar to the use of the binaural stethoscope. This paper will specifically review how POCUS improves the limited sensitivity of the current practice of traditional cardiac physical examination by both cardiologists and non-cardiologists. Signs of left ventricular systolic dysfunction, left atrial enlargement, lung congestion and elevated central venous pressures are often missed by physical techniques but can be easily detected by POCUS and have prognostic and treatment implications. Creating a general set of repetitive imaging skills for these entities for application on all patients during routine examination will standardise and reduce heterogeneity in cardiac bedside ultrasound applications, simplify teaching curricula, enhance learning and recollection, and unify competency thresholds and practice. The addition of POCUS to standard physical examination techniques in cardiovascular medicine will result in an ultrasound-augmented cardiac physical examination that reaffirms the value of bedside diagnosis. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Riguzzi, Christine; Losonczy, Lia; Teismann, Nathan; Herring, Andrew A; Nagdev, Arun
2014-11-01
Abdominal angioedema is a less recognized type of angioedema, which can occur in patients with hereditary angioedema (HAE). The clinical signs may range from subtle, diffuse abdominal pain and nausea, to overt peritonitis. We describe two cases of abdominal angioedema in patients with known HAE that were diagnosed in the emergency department by point-of-care (POC) ultrasound. In each case, the patient presented with isolated abdominal complaints and no signs of oropharyngeal edema. Findings on POC ultrasound included intraperitoneal free fluid and bowel wall edema. Both patients recovered uneventfully after receiving treatment. Because it can be performed rapidly, requires no ionizing radiation, and can rule out alternative diagnoses, POC ultrasound holds promise as a valuable tool in the evaluation and management of patients with HAE.
[Technique of abdominal ultrasonography in newborn foals and normal findings].
Behn, C; Bostedt, H
2000-09-01
Under field conditions, the diagnosis of foal's diseases relies almost exclusively on the physical examination. As the signs of illness in the equine neonate are frequently vage and non-localizing, the diagnosis of diseases may be problematic. This often causes misinterpretations and leads to ineffective prophylaxis and treatment. The purpose of this study was to evaluate the usefulness of diagnostic ultrasonography of the foal's abdomen under field conditions to provide an optimized technique and to describe the normal findings. Diagnostic ultrasonography of the abdomen was performed after obtaining clinical history and passing the physical examination of 25 foals without signs of abdominal problems. The foals were scanned in a stable box, being restrained by three persons in semi-lateral recumbency. Usually, sedation was not necessary. The ventral abdominal wall was clipped, a generous amount of ultrasound coupling gel was applied and massaged on the skin surface. The ultrasonographic examination was carried out using a portable sector scanner ("Microimager 2000", Ausonics) with 5.0 and 7.5-MHz transducers or a combined 5.0 and 7.5-MHz transrectal linear-array scanner ("450 Enhanced", Pie Medical). Employing the 5.0-MHz sector scanner first, the abdomen was explored from caudal to cranial in left and right semi-lateral recumbency. The 7.5-MHz scanner was used to attain higher resolution of certain structures. The sector scanner turned out to be suitable under field conditions and adequate to examine the abdominal organs. The transrectal linear-array scanner also provided the most important informations, although it was difficult to maintain a good contact area of the scan head. By ultrasonography it was possible to identify the urinary bladder, kidneys, spleen, liver and part of the gastrointestinal tract. Thus, application of ultrasound could successfully be performed on newborn foals under field conditions.
Tamarozzi, Francesca; Hou, Amy; Morales, Maria Luisa; Giordani, Maria Teresa; Vilca, Freddy; Mozo, Karen; Bascope, Ruben; White, A. Clinton; Brunetti, Enrico; Chen, Lin; Cabada, Miguel M.
2017-01-01
Latin America is among the highly endemic regions for cystic echinococcosis (CE). In Peru, an estimated 1,139 disability-adjusted life years are lost annually from surgical treatment of CE. This is comparable with the combined total for Argentina, Brazil, Uruguay, and Chile. The prevalence of human infection has been investigated in the central Peruvian Andes, but there are no community-based screening data from other regions of Peru. We carried out a population survey in January 2015 using abdominal ultrasound to estimate the prevalence of abdominal CE in the Canas and Canchis provinces, in the Cusco region of Peru. Among 1,351 subjects screened, 41 (3%) had CE. There was significant variation between communities with similar socioeconomic features in a small geographical area. A history of CE was reported by 4.1% of the screened subjects, among whom 30.3% still had CE on ultrasound. Among patients reporting previous CE treatment, 14.9% had CE in active stages. Limited education, community of residence, and knowing people with CE in the community were associated with CE. These results demonstrate a significant burden of CE in the region and suggest the need for further investigations, control activities, and optimization of clinical management for CE in this area. PMID:28719254
Abuhamad, Alfred; Zhao, Yili; Abuhamad, Sharon; Sinkovskaya, Elena; Rao, Rashmi; Kanaan, Camille; Platt, Lawrence
2016-01-01
This study aims to validate the feasibility and accuracy of a new standardized six-step approach to the performance of the focused basic obstetric ultrasound examination, and compare the new approach to the regular approach performed in the scheduled obstetric ultrasound examination. A new standardized six-step approach to the performance of the focused basic obstetric ultrasound examination, to evaluate fetal presentation, fetal cardiac activity, presence of multiple pregnancy, placental localization, amniotic fluid volume evaluation, and biometric measurements, was prospectively performed on 100 pregnant women between 18(+0) and 27(+6) weeks of gestation and another 100 pregnant women between 28(+0) and 36(+6) weeks of gestation. The agreement of findings for each of the six steps of the standardized six-step approach was evaluated against the regular approach. In all ultrasound examinations performed, substantial to perfect agreement (Kappa value between 0.64 and 1.00) was observed between the new standardized six-step approach and the regular approach. The new standardized six-step approach to the focused basic obstetric ultrasound examination can be performed successfully and accurately between 18(+0) and 36(+6) weeks of gestation. This standardized approach can be of significant benefit to limited resource settings and in point of care obstetric ultrasound applications. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Lee, Sugun; Kim, Hee-Jin; Park, Hyun Jun; Kim, Hyoung Moon; Lee, So Hyun; Cho, Sung Bin
2017-07-01
Non-focused ultrasound and high-intensity focused ultrasound (HIFU) devices induce lipolysis by generating acoustic cavitation and coagulation necrosis in targeted tissues. We aimed to investigate the morphometric characteristics of immediate tissue reactions induced by 2 MHz, 13-mm focused HIFU via two-dimensional ultrasound images and histologic evaluation of cadaveric skin from the abdomen and thigh. Acoustic fields of a 2 MHz, 38-mm HIFU transducer were characterized by reconstruction of the fields using acoustic intensity measurement. Additionally, abdominal and thigh tissues from a fresh cadaver were treated with a HIFU device for a single, two, and three pulses at the pulse energy of 130 J/cm 2 and a penetration depth of 13 mm. Acoustic intensity measurement revealed characteristic focal zones of significant thermal injury at the depth of 38 mm. In both the abdomen and thigh tissue, round to oval ablative thermal injury zones (TIZs) were visualized in subcutaneous fat layers upon treatment with a single pulse of HIFU treatment. Two to three HIFU pulses generated larger and more remarkable ablative zones throughout subcutaneous fat layers. Finally, experimental treatment in a tumescent infiltration-like setting induced larger HIFU-induced TIZs of an oval or columnar shape, compared to non-tumescent settings. Although neither acoustic intensity measurement nor cadaveric tissue exactly reflects in vivo HIFU-induced reactions in human tissue, we believe that our data will help guide further in vivo studies in investigating the therapeutic efficacy and safety of HIFU-induced lipolysis.
Røjskjaer, Jesper O; Gade, Erik; Kiel, Louise B; Lind, Morten N; Pedersen, Lars M; Kristensen, Billy B; Rasmussen, Yvonne H; Foss, Nicolai B
2015-03-01
To assess the effect of bilateral ultrasound-guided transversus abdominis plane block with ropivacaine compared with placebo as part of a multimodal analgesic regimen. A randomized, double-blind, placebo-controlled trial following the CONSORT criteria. Hvidovre University Hospital. Forty-six women scheduled for total abdominal hysterectomy. Women received either ropivacaine 0.75%, 20 mL (n = 24) or 0.9% saline, 20 mL (n = 24) in the transversus abdominis plane on each side. Primary outcome was the 24-h postoperative morphine consumption. Secondary outcomes were pain scores at rest and during coughing, postoperative nausea and vomiting at 1, 2, 4, 6, 8, and 24 h, and time to first mobilization. There was no difference in the mean 24-h postoperative morphine consumption between the two groups (p = 0.733). The ropivacaine group had significantly lower median pain scores at 1 h (p = 0.008) and 2 h (p = 0.027) postoperatively at rest and at 8 h (p = 0.028) during coughing. There was no significant difference in other secondary outcomes. There was no reduction in 24-h morphine consumption when using an ultrasound-guided transversus abdominis plane block in women undergoing total abdominal hysterectomy. As part of a multimodal regimen the transversus abdominis plane block showed some effect on pain scores at rest only in the early postoperative period. © 2014 Nordic Federation of Societies of Obstetrics and Gynecology.
Colli, Agostino; Prati, Daniele; Fraquelli, Mirella; Segato, Sergio; Vescovi, Pier Paolo; Colombo, Fabrizio; Balduini, Carlo; Della Valle, Serena; Casazza, Giovanni
2015-01-01
The performance of pocket mobile ultrasound devices (PUDs) is comparable with that of standard ultrasonography, whereas the accuracy of a physical examination is often poor requiring further tests to assess diagnostic hypotheses. Adding the use of PUD to physical examination could lead to an incremental benefit. We assessed whether the use of PUD in the context of physical examination can reduce the prescription of additional tests when used by physicians in different clinical settings. We conducted a cohort impact study in four hospital medical wards, one gastroenterological outpatient clinic, and 90 general practices in the same geographical area. The study involved 135 physicians who used PUD, after a short predefined training course, to examine 1962 consecutive patients with one of 10 diagnostic hypotheses: ascites, pleural effusion, pericardial effusion, urinary retention, urinary stones, gallstones, biliary-duct dilation, splenomegaly, abdominal mass, abdominal aortic aneurysm. According to the physicians' judgment, PUD examination could rule out or in the diagnostic hypothesis or require further testing; the concordance with the final diagnosis was assessed. The main outcome was the proportion of cases in which additional tests were required after PUD. The PUD diagnostic accuracy was assessed in patients submitted to further testing. The 1962 patients included 37% in-patients, 26% gastroenterology outpatients, 37% from general practices. Further testing after PUD examination was deemed unnecessary in 63%. Only 5% of patients with negative PUD not referred for further testing were classified false negatives with respect to the final diagnosis. In patients undergoing further tests, the sensitivity was 91%, and the specificity 83%. After a simple and short training course, a PUD examination can be used in addition to a physical examination to improve the answer to ten common clinical questions concerning in- and outpatients, and can reduce the need for further
Automated abdominal plane and circumference estimation in 3D US for fetal screening
NASA Astrophysics Data System (ADS)
Lorenz, C.; Brosch, T.; Ciofolo-Veit, C.; Klinder, T.; Lefevre, T.; Cavallaro, A.; Salim, I.; Papageorghiou, A. T.; Raynaud, C.; Roundhill, D.; Rouet, L.; Schadewaldt, N.; Schmidt-Richberg, A.
2018-03-01
Ultrasound is increasingly becoming a 3D modality. Mechanical and matrix array transducers are able to deliver 3D images with good spatial and temporal resolution. The 3D imaging facilitates the application of automated image analysis to enhance workflows, which has the potential to make ultrasound a less operator dependent modality. However, the analysis of the more complex 3D images and definition of all examination standards on 2D images pose barriers to the use of 3D in daily clinical practice. In this paper, we address a part of the canonical fetal screening program, namely the localization of the abdominal cross-sectional plane with the corresponding measurement of the abdominal circumference in this plane. For this purpose, a fully automated pipeline has been designed starting with a random forest based anatomical landmark detection. A feature trained shape model of the fetal torso including inner organs with the abdominal cross-sectional plane encoded into the model is then transformed into the patient space using the landmark localizations. In a free-form deformation step, the model is individualized to the image, using a torso probability map generated by a convolutional neural network as an additional feature image. After adaptation, the abdominal plane and the abdominal torso contour in that plane are directly obtained. This allows the measurement of the abdominal circumference as well as the rendering of the plane for visual assessment. The method has been trained on 126 and evaluated on 42 abdominal 3D US datasets. An average plane offset error of 5.8 mm and an average relative circumference error of 4.9 % in the evaluation set could be achieved.
Functional anatomy and ultrasound examination of the canine penis.
Goericke-Pesch, Sandra; Hölscher, Catharina; Failing, Klaus; Wehrend, Axel
2013-07-01
The aim of this study was to identify the functional-anatomical structures of the canine penis during and after erection to demonstrate the respective changes to provide a basis for further examinations of pathological conditions like priapism. Additionally, a gray-scale analysis was performed to quantify results from the ultrasound examination. In total, 80 dogs were examined. In group (Gr.) A, 44 intact or castrated dogs were examined, and in Gr. B, 36 dogs were examined during erection and after complete detumescence of the penis. The following parameters were assessed: (1) using physical measurements: length of the Pars longa glandis [Plg] and length of the Bulbus glandis [Bg]; and (2) using ultrasound: total penile diameter, width of the erectile tissue of the Plg, diameter of the Corpus spongiosum [Cs] including the penile bone and urethra, vertical diameter, circumference of the penis, cross-sectional area, and area of the Cs including the urethra. The mentioned parameters could be assessed in all dogs of Gr. A and Gr. B with the only exception being the urethra that could be visualized using ultrasound in some dogs only and predominantly in the erected penis (Gr. B). Concomitantly, the erectile tissue of the Plg and the Cs was more heterogenous and hypo- to anechoic during erection compared with dogs in Gr. A and Gr. B after detumescence. Comparing the results in Gr. B, the length of the Plg and the Bg were decreased approximately 40.6% and 38.0%, the total width of the penis 40.5%, the total width of the erectile tissue of the Plg 48.0%, and the width of the Cs 15.6% during detumescence compared with erection. Comparing the decrease in size at the different locations (apex penis, middle of Plg, middle of Bg) for vertical diameter, total circumference, and cross-section area, it was largest at the Bg. B-mode ultrasound is a suitable tool to investigate not only the morpho-functional structures of the resting canine penis, but also of the erected and
Suzuki, Rei; Irisawa, Atsushi; Bhutani, Manoop S; Hikichi, Takuto; Takagi, Tadayuki; Shibukawa, Goro; Sato, Ai; Sato, Masaki; Ikeda, Tsunehiko; Watanabe, Ko; Nakamura, Jun; Annangi, Srinadh; Tasaki, Kazuhiro; Obara, Katsutoshi; Ohira, Hiromasa
2014-01-01
AIM: To evaluate the feasibility of using an automated spring-loaded needle device for endoscopic ultrasound (EUS)-guided abdominal paracentesis (EUS-P) to see if this would make it easier to puncture the mobile and lax gastric wall for EUS-P. METHODS: The EUS database and electronic medical records at Fukushima Medical University Hospital were searched from January 2001 to April 2011. Patients with a history of cancer and who underwent EUS-P using an automated spring-loaded needle device with a 22-gauge puncture needle were included. The needle was passed through the instrument channel and advanced through the gastrointestinal wall under EUS guidance into the echo-free space in the abdominal cavity and ascitic fluid was collected. The confirmed diagnosis of malignant ascites included positive cytology and results from careful clinical observation for at least 6 mo in patients with negative cytology. The technical success rate, cytology results and complications were evaluated. RESULTS: We found 11 patients who underwent EUS-P with an automated spring-loaded needle device. In 4 cases, ascites was revealed only with EUS but not in other imaging modalities. EUS-P was done in 7 other cases because there was minimal ascitic fluid and no safe window for percutaneous abdominal aspiration. Ascitic fluid was obtained in all cases by EUS-P. The average amount aspirated was 14.1 mL (range 0.5-38 mL) and that was sent for cytological exam. The etiology of ascitic fluid was benign in 5 patients and malignant in 6. In all cases, ascitic fluid was obtained with the first needle pass. No procedure-related adverse effects occurred. CONCLUSION: EUS-P with an automated spring-loaded needle device is a feasible and safe method for ascites evaluation. PMID:24567793
Feasibility of a focused ultrasound training programme for medical undergraduate students.
Wong, Ivan; Jayatilleke, Thilina; Kendall, Richard; Atkinson, Paul
2011-03-01
Although ultrasound is a core skill for many clinical specialties, UK medical schools are not currently required to teach this skill. The College of Emergency Medicine (CEM) has championed the use of ultrasound to answer focused clinical questions in emergency settings. We have designed and piloted an ultrasound training course for undergraduate medical students addressing one important indication: ultrasound assessment of the abdominal aorta. Fourteen clinical students, who had no prior experience of using ultrasound, received focused ultrasound training in the form of didactic instruction, a short bedside practical workshop and self-directed learning over a 20-day period. At the end of this period, the students were assessed by a structured viva and an observed structured clinical examination (OSCE) used for accreditation by the CEM. The primary endpoint was the number of students who passed the assessment. The secondary endpoint was the accuracy of the students' anatomical measurements. Thirteen of the 14 (93%) students completed the training and assessment. Eight of the 13 (62%) students passed both the viva and OSCE, and were deemed to have achieved the CEM standard. The measurements by the competent students were not statistically different from those of experienced practitioners. We have shown for the first time that it is feasible to train inexperienced undergraduate students to scan the abdominal aorta to a professional standard using a focused training course. It is time for the medical education community to address whether focused ultrasound training should accompany traditional clinical skills, such as using a stethoscope, in UK medical school curricula. © Blackwell Publishing Ltd 2011.
A navigation system for flexible endoscopes using abdominal 3D ultrasound
NASA Astrophysics Data System (ADS)
Hoffmann, R.; Kaar, M.; Bathia, Amon; Bathia, Amar; Lampret, A.; Birkfellner, W.; Hummel, J.; Figl, M.
2014-09-01
A navigation system for flexible endoscopes equipped with ultrasound (US) scan heads is presented. In contrast to similar systems, abdominal 3D-US is used for image fusion of the pre-interventional computed tomography (CT) to the endoscopic US. A 3D-US scan, tracked with an optical tracking system (OTS), is taken pre-operatively together with the CT scan. The CT is calibrated using the OTS, providing the transformation from CT to 3D-US. Immediately before intervention a 3D-US tracked with an electromagnetic tracking system (EMTS) is acquired and registered intra-modal to the preoperative 3D-US. The endoscopic US is calibrated using the EMTS and registered to the pre-operative CT by an intra-modal 3D-US/3D-US registration. Phantom studies showed a registration error for the US to CT registration of 5.1 mm ± 2.8 mm. 3D-US/3D-US registration of patient data gave an error of 4.1 mm compared to 2.8 mm with the phantom. From this we estimate an error on patient experiments of 5.6 mm.
Abdominal calcifications and diagnostic imaging decision making: a topic review
Bassano, John M.
2006-01-01
Abstract Objective To review commonly encountered calcifications found within the abdomen as seen on the lumbar spine radiograph and to determine which advanced imaging modality is best to thoroughly assess the patient. Methods Searches of electronic databases and textbooks were conducted to construct this narrative overview. Discussion By categorizing the type of calcification and localizing it anatomically, most often a definitive diagnosis can be reached. Two commonly encountered conditions, abdominal aortic aneurysms and urinary calculi, are used to compare the main advanced imaging modalities (diagnostic ultrasound and computed tomography) used to further assess abdominal calcifications. Conclusion In most circumstances, either diagnostic ultrasound or computed tomography will establish a definitive diagnosis and offer thorough imaging assessment for abdominal calcifications. PMID:19674671
How useful is abdominal ultrasonography in dogs with diarrhoea?
Mapletoft, E K; Allenspach, K; Lamb, C R
2018-01-01
To assess the utility of abdominal ultrasonography in the diagnostic work-up of dogs with diarrhoea. Retrospective cross-sectional study based on a referral population of dogs with diarrhoea. Associations between the clinical signs, use of abdominal ultrasonography, results of abdominal ultrasonography and subsequent work-up were examined. The utility of abdominal ultrasonography was scored as high, moderate, none or counterproductive based on review of medical records. Medical records of 269 dogs were reviewed, of which 149 (55%) had abdominal ultrasonography. The most frequent result was no ultrasonographic abnormalities affecting the intestine in 65 (44%) dogs. Ultrasonography results were associated with subsequent work-up as follows: (1) no detected abnormalities and dietary trial; (2) focal thickening of the intestinal wall, loss of intestinal wall layers or enlarged abdominal lymph nodes and ultrasound-guided fine-needle aspirates; (3) diffuse thickening of the intestinal wall or hyperechoic striations in the small intestinal mucosa and endoscopy; and (4) small intestinal foreign body and coeliotomy. Abdominal ultrasonography was considered to be diagnostic without further testing in only four (3%) dogs: two had a portosystemic shunt identified ultrasonographically, one had a linear foreign body and one had a perforated pyloric ulcer. Abdominal ultrasonography had moderate utility in 56 (38%) dogs and no utility in 79 (53%) dogs. Abdominal ultrasonography was considered counterproductive in 10 (7%) dogs because results were either falsely negative or falsely positive. These results should prompt clinicians to reconsider routine use of abdominal ultrasonography in dogs with diarrhoea. © 2017 British Small Animal Veterinary Association.
Ultrasound as Diagnostic Tool for Diaphragmatic Myoclonus
Llaneza Ramos, Vesper Fe Marie; Considine, Elaine; Karp, Barbara I.; Lungu, Codrin; Alter, Katharine; Hallett, Mark
2015-01-01
Background Diaphragmatic myoclonus is a rare disorder of repetitive diaphragmatic contractions, acknowledged to be a spectrum that includes psychogenic features. Electromyography has been the diagnostic tool most commonly used in the literature. Methods To test if we could perform a noninvasive technique to delineate the diaphragm as the source of abnormal movements and demonstrate distractibility and entrainability, we used B-mode ultrasound in a patient with diaphragmatic myoclonus. Results Ultrasound imaging clearly delineated the diaphragm as the source of her abdominal movements. We were able to demonstrate entrainability of the diaphragm to hand tapping to a prescribed rhythm set by examiner. Conclusion We recommend the use of ultrasound as a noninvasive, convenient diagnostic tool for further studies of diaphragmatic myoclonus. We agree with previous findings that diaphragmatic myoclonus may be a functional movement disorder, as evidenced by distractibility and entrainability demonstrated on real-time video with ultrasonography. PMID:27430001
Ultrasound in athletes: emerging techniques in point-of-care practice.
Yim, Eugene S; Corrado, Gianmichel
2012-01-01
Ultrasound offers sports medicine clinicians the potential to diagnose, treat, and manage a broad spectrum of conditions afflicting athletes. This review article highlights applications of ultrasound that hold promise as point-of-care diagnostics and therapeutic tools that can be used directly by clinicians to direct real-time management of athletes. Point-of-care ultrasound has been examined most in the context of musculoskeletal disorders in athletes, with attention given to Achilles tendinopathy, patellar tendinopathy, hip and thigh pathology, elbow tendinopathy, wrist pathology, and shoulder pain. More research has focused on therapeutic applications than diagnostic, but initial evidence has been generated in both. Preliminary evidence has been published also on abdominal ultrasound for splenic enlargement in mononucleosis, cardiopulmonary processes and hydration status, deep vein thrombosis, and bone mineral density. Further research will be required to validate these applications and to explore further applications of portable ultrasound that can be used in the care of athletes.
El Sherif, Fatma Adel; Mohamed, Sahar Abdel-Baky; Kamal, Shereen Mamdouh
2017-06-01
Transversus abdominis plane (TAP) block used for management of surgical abdominal pain by injecting local anesthetics into the plane between the internal oblique and transversus abdominis muscles. We aimed to explore the effect of adding morphine to bupivacaine in ultrasound guided TAP-block in patients undergoing lower abdominal cancer surgery. Randomized, double-blind, prospective study. Clinical trial identifier: NCT02566096. Academic medical center. Sixty patients were enrolled in this study after ethical committee approval. Patients divided into 2 groups (30 each): Bupivacaine group (GB): given ultrasound guided TAP-block 20ml 0.5% bupivacaine diluted in 20ml saline; Morphine group (GM): given ultrasound guided TAP-block with 20ml 0.5% bupivacaine+10mg morphine sulphate diluted in 20ml saline. Patients were observed for total morphine consumption, time for first request of rescue analgesia, sedation scores, hemodynamics and side effects for 24h postoperatively. Morphine added to bupivacaine in TAP block compared to bupivacaine alone reduced total morphine consumption (5.33±1.28mg) (10.70±3.09mg) respectively (p<0.001), prolonged the time to first request of analgesia (10.40±4.96h) (6.97±3.26h) respectively (p<0.008), with a statistically significant decrease in (VAS-M) in GM compared with GB at 12h postoperatively (p<0.002). No significant differences in hemodynamics, respiratory rate, oxygen saturation, sedation score, and side effects except for nausea were observed (p>0.05). Addition of morphine to bupivacaine in TAP block is effective method for pain management in patients undergoing major abdominal cancer surgery without serious side effects. Copyright © 2017 Elsevier Inc. All rights reserved.
Technical aspects of contrast-enhanced ultrasound (CEUS) examinations: tips and tricks.
Greis, C
2014-01-01
Ultrasound contrast agents have substantially extended the clinical value of ultrasound, allowing the assessment of blood flow and distribution in real-time down to microcapillary level. Selective imaging of contrast agent signals requires a contrast-specific imaging mode on the ultrasound scanner, allowing real-time separation of tissue and contrast agent signals. The creation of a contrast image requires a specific interaction between the insonated ultrasound wave and the contrast agent microbubbles, leading to persistent oscillation of the bubbles. Several technical and procedural parameters have a significant influence on the quality of CEUS images and should be controlled carefully to obtain good image quality and a reliable diagnosis. Achieving the proper balance between the respective parameters is a matter of technical knowledge and experience. Appropriate training and education should be mandatory for every investigator performing CEUS examinations.
Chaudhari, Uddhav K; Imran, M; Manjramkar, Dhananjay D; Metkari, Siddhanath M; Sable, Nilesh P; Gavhane, Dnyaneshwar S; Katkam, Rajendra R; Sachdeva, Geetanjali; Thakur, Meenakshi H; Kholkute, Sanjeeva D
2017-02-01
Ultrasound is a powerful, low-cost, non-invasive medical tool used by laboratory animal veterinarians for diagnostic imaging. Sonohysterography and transvaginal ultrasound are frequently used to assess uterine anomalies in women presenting with abnormal uterine bleeding (AUB). In the present study, we have evaluated the abdominal ultrasound of bonnet monkeys ( n = 8) showing spontaneous ovulatory ( n = 5) and anovulatory ( n = 3) AUB. The ovulatory ( n = 5) macaques showed cyclic AUB for 7-8 days. The anovulatory ( n = 3) macaques had irregular AUB with menstrual cycles of 40-45 days. The B-mode abdominal, colour Doppler and 3D ultrasound scans were performed during the proliferative phase of the menstrual cycle. Ultrasound examination revealed endometrial polyps in five macaques and endometrial hyperplasia in three animals. The width and length of endometrial polyps was around 0.5-1 cm (average 0.51 ± 0.23 cm × 0.96 ± 0.16 cm) with significant increase in endometrial thickness ( P < 0.0002). 3D ultrasound also showed a homogeneous mass in the uterine cavity and colour Doppler ultrasound showed increased vascularity in the endometrial polyps. Endometrial hyperplasia characteristically appeared as a thickened echogenic endometrium ( P < 0.0002). This study demonstrates the use of non-invasive ultrasound techniques in the diagnosis of AUB in macaques.
Mitchell, John D; Amir, Rabia; Montealegre-Gallegos, Mario; Mahmood, Feroze; Shnider, Marc; Mashari, Azad; Yeh, Lu; Bose, Ruma; Wong, Vanessa; Hess, Philip; Amador, Yannis; Jeganathan, Jelliffe; Jones, Stephanie B; Matyal, Robina
2018-06-01
While standardized examinations and data from simulators and phantom models can assess knowledge and manual skills for ultrasound, an Objective Structured Clinical Examination (OSCE) could assess workflow understanding. We recruited 8 experts to develop an OSCE to assess workflow understanding in perioperative ultrasound. The experts used a binary grading system to score 19 graduating anesthesia residents at 6 stations. Overall average performance was 86.2%, and 3 stations had an acceptable internal reliability (Kuder-Richardson formula 20 coefficient >0.5). After refinement, this OSCE can be combined with standardized examinations and data from simulators and phantom models to assess proficiency in ultrasound.
Gottstein, Bruno; Cracknell, John; Schwab, Gerhard; Rosell, Frank
2015-01-01
Echinococcus multilocularis is an important pathogenic zoonotic parasite of health concern, though absent in the United Kingdom. Eurasian beavers (Castor fiber) may act as a rare intermediate host, and so unscreened wild caught individuals may pose a potential risk of introducing this parasite to disease-free countries through translocation programs. There is currently no single definitive ante-mortem diagnostic test in intermediate hosts. An effective non-lethal diagnostic, feasible under field condition would be helpful to minimise parasite establishment risk, where indiscriminate culling is to be avoided. This study screened live beavers (captive, n = 18 or wild-trapped in Scotland, n = 12) and beaver cadavers (wild Scotland, n = 4 or Bavaria, n = 11), for the presence of E. multilocularis. Ultrasonography in combination with minimally invasive surgical examination of the abdomen by laparoscopy was viable under field conditions for real-time evaluation in beavers. Laparoscopy alone does not allow the operator to visualize the parenchyma of organs such as the liver, or inside the lumen of the gastrointestinal tract, hence the advantage of its combination with abdominal ultrasonography. All live beavers and Scottish cadavers were largely unremarkable in their haematology and serum biochemistry with no values suspicious for liver pathology or potentially indicative of E. multilocularis infection. This correlated well with ultrasound, laparoscopy, and immunoblotting, which were unremarkable in these individuals. Two wild Bavarian individuals were suspected E. multilocularis positive at post-mortem, through the presence of hepatic cysts. Sensitivity and specificity of a combination of laparoscopy and abdominal ultrasonography in the detection of parasitic liver cyst lesions was 100% in the subset of cadavers (95%Confidence Intervals 34.24–100%, and 86.7–100% respectively). For abdominal ultrasonography alone sensitivity was only 50% (95%CI 9.5–90.6%), with
Epidemiology and contemporary management of abdominal aortic aneurysms.
Ullery, Brant W; Hallett, Richard L; Fleischmann, Dominik
2018-05-01
Abdominal aortic aneurysm (AAA) is most commonly defined as a maximal diameter of the abdominal aorta in excess of 3 cm in either anterior-posterior or transverse planes or, alternatively, as a focal dilation ≥ 1.5 times the diameter of the normal adjacent arterial segment. Risk factors for the development of AAA include age > 60, tobacco use, male gender, Caucasian race, and family history of AAA. Aneurysm growth and rupture risk appear to be associated with persistent tobacco use, female gender, and chronic pulmonary disease. The majority of AAAs are asymptomatic and detected incidentally on various imaging studies, including abdominal ultrasound, and computed tomographic angiography. Symptoms associated with AAA may include abdominal or back pain, thromboembolization, atheroembolization, aortic rupture, or development of an arteriovenous or aortoenteric fistula. The Screening Abdominal Aortic Aneurysms Efficiently (SAAAVE) Act provides coverage for a one-time screening abdominal ultrasound at age 65 for men who have smoked at least 100 cigarettes and women who have family history of AAA disease. Medical management is recommended for asymptomatic patients with AAAs < 5 cm in diameter and focuses on modifiable risk factors, including smoking cessation and blood pressure control. Primary indications for intervention in patients with AAA include development of symptoms, rupture, rapid aneurysm growth (> 5 mm/6 months), or presence of a fusiform aneurysm with maximum diameter of 5.5 cm or greater. Intervention for AAA includes conventional open surgical repair and endovascular aortic stent graft repair.
King, Hollis H; Cayce, Charles Thomas; Herrin, Jeph
Early osteopathic theory and practice, and the work of the medical intuitive Edgar Cayce suggested that the abdominal areas of individuals with epilepsy would manifest "cold spots." The etiology for this phenomenon was thought to be abdominal adhesions caused by inflammation and viscero-somatic reflexes caused by adhesions or injury to visceral or musculoskeletal system structures. Indeed, until that advent of electroencephalography in the 1930s, medical practice regarding epilepsy focused on abdominal neural and visceral structures. Following two hypotheses were formulated to evaluate any abdominal temperature phenomena: (1) an abdominal quadrant division analysis would find one or more quadrants "colder" in the focal-onset epilepsy group (ICD9-CM 345.4 and 345.5) compared to controls. (2) Total abdominal areas of individuals with focal-onset epilepsy wound be colder than a control group. Overall, 50 patients with the diagnosis of focal-onset epilepsy were recruited from the office of the Epilepsy Foundation of Florida and 50 control subjects with no history of epilepsy were recruited through advertising to the public. Under controlled room conditions all subjects had infrared thermographic images made and recorded by Med-Hot Model MH-731 FLIR equipment. There were no significant demographic difference between experimental patients and control subjects, though the control group tended to be younger and more often male; however, these were controlled for in all analyses. In the quadrant analysis, there were significant differences in that more epileptic patients had colder left upper abdominal quadrant temperatures than the control group (66.8% versus 44.9%; P = .030). In the total abdominal analysis, however, there were no significant differences. The results support the hypothesis that individuals with focal-onset epilepsy have colder abdominal areas. If substantiated in further research, present study results will require further examination of the mechanisms of
Benabbas, Roshanak; Hanna, Mark; Shah, Jay; Sinert, Richard
2017-05-01
Acute appendicitis (AA) is the most common surgical emergency in children. Accurate and timely diagnosis is crucial but challenging due to atypical presentations and the inherent difficulty of obtaining a reliable history and physical examination in younger children. The aim of this study was to determine the utility of history, physical examination, laboratory tests, Pediatric Appendicitis Score (PAS) and Emergency Department Point-of-Care Ultrasound (ED-POCUS) in the diagnosis of AA in ED pediatric patients. We performed a systematic review and meta-analysis and used a test-treatment threshold model to identify diagnostic findings that could rule in/out AA and obviate the need for further imaging studies, specifically computed tomography (CT) scan, magnetic resonance imaging (MRI), and radiology department ultrasound (RUS). We searched PubMed, EMBASE, and SCOPUS up to October 2016 for studies on ED pediatric patients with abdominal pain. Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS-2) was used to evaluate the quality and applicability of included studies. Positive and negative likelihood ratios (LR+ and LR-) for diagnostic modalities were calculated and when appropriate data was pooled using Meta-DiSc. Based on the available literature on the test characteristics of different imaging modalities and applying the Pauker-Kassirer method we developed a test-treatment threshold model. Twenty-one studies were included encompassing 8,605 patients with weighted AA prevalence of 39.2%. Studies had variable quality using the QUADAS-2 tool with most studies at high risk of partial verification bias. We divided studies based on their inclusion criteria into two groups of "undifferentiated abdominal pain" and abdominal pain "suspected of AA." In patients with undifferentiated abdominal pain, history of "pain migration to right lower quadrant (RLQ)" (LR+ = 4.81, 95% confidence interval [CI] = 3.59-6.44) and presence of "cough/hop pain" in the physical
Deputy, Nicholas P; Nguyen, Phuong H; Pham, Hoa; Nguyen, Son; Neufeld, Lynnette; Martorell, Reynaldo; Ramakrishnan, Usha
2017-01-11
Accurate estimation of gestational age is important for both clinical and public health purposes. Estimates of gestational age using fetal ultrasound measurements are considered most accurate but are frequently unavailable in low- and middle-income countries. The objective of this study was to assess the validity of last menstrual period and Farr neonatal examination estimates of gestational age, compared to ultrasound estimates, in a large cohort of women in Vietnam. Data for this analysis come from a randomized, placebo-controlled micronutrient supplementation trial in Vietnam. We analyzed 912 women with ultrasound and prospectively-collected last menstrual period estimates of gestational age and 685 women with ultrasound and Farr estimates of gestational age. We used the Wilcoxon signed rank sum test to assess differences in gestational age estimated by last menstrual period or Farr examination compared to ultrasound and computed the intraclass correlation coefficient (ICC) and concordance correlation coefficient (CCC) to quantify agreement between methods. We computed the Kappa coefficient (κ) to quantify agreement in preterm, term and post-term classification. The median gestational age estimated by ultrasound was 273.9 days. Gestational age was slightly overestimated by last menstrual period (median 276.0 days, P < 0.001) and more greatly overestimated by Farr examination (median 286.7 days, P < 0.001). Gestational age estimates by last menstrual period and ultrasound were moderately correlated (ICC = 0.78) and concordant (CCC = 0.63), whereas gestational age estimates by Farr examination and ultrasound were weakly correlated (ICC = 0.26) and concordant (CCC = 0.05). Last menstrual period and ultrasound estimates of gestational age were within ± 14 days for 88.4% of women; Farr and ultrasound estimates were within ± 14 days for 55.8% of women. Last menstrual period and ultrasound estimates of gestational age had higher
The quality of research on physical examination for abdominal aortic aneurysm.
Nunnelee, Janice D; Spaner, Steven D
2004-03-01
A review of nursing literature revealed no studies regarding physical examination or other interventions (except unit based) for abdominal aortic aneurysms (AAA). The physician literature was explored, revealing an excellent meta-analysis in 1999 of studies before that date with regard to physician accuracy in physical examination for AAA. These are reviewed for quality and recommendations made for nursing research and the role of the Society for Vascular Nursing in teaching nurses.
Mitrea, Delia; Mitrea, Paulina; Nedevschi, Sergiu; Badea, Radu; Lupsor, Monica; Socaciu, Mihai; Golea, Adela; Hagiu, Claudia; Ciobanu, Lidia
2012-01-01
The noninvasive diagnosis of the malignant tumors is an important issue in research nowadays. Our purpose is to elaborate computerized, texture-based methods for performing computer-aided characterization and automatic diagnosis of these tumors, using only the information from ultrasound images. In this paper, we considered some of the most frequent abdominal malignant tumors: the hepatocellular carcinoma and the colonic tumors. We compared these structures with the benign tumors and with other visually similar diseases. Besides the textural features that proved in our previous research to be useful in the characterization and recognition of the malignant tumors, we improved our method by using the grey level cooccurrence matrix and the edge orientation cooccurrence matrix of superior order. As resulted from our experiments, the new textural features increased the malignant tumor classification performance, also revealing visual and physical properties of these structures that emphasized the complex, chaotic structure of the corresponding tissue. PMID:22312411
McCarville, M. Beth; Luo, Zhaoyu; Huang, Xiangke; Rees, Renee C.; Rogers, Zora R.; Miller, Scott T.; Thompson, Bruce; Kalpatthi, Ram; Wang, Winfred C.
2015-01-01
OBJECTIVE The purpose of this study is to perform and evaluate baseline abdominal ultrasound in infants with sickle cell anemia who participated in the BABY HUG multiinstitutional randomized placebo-controlled trial of hydroxyurea therapy and to examine the potential relationships among ultrasound results and clinical, nuclear medicine, and laboratory data. SUBJECTS AND METHODS After local institutional review board approval and with informed guardian consent, 116 girls and 87 boys (age range, 7.5–18 months) with sickle cell anemia underwent standardized abdominal sonography at 14 institutions. Imaging was centrally reviewed by one radiologist who assessed and measured the spleen, kidneys, gallbladder, and common bile duct. Baseline physical assessment of spleen size, serum alanine aminotransferase and bilirubin levels, 99mTc sulfur colloid liver-spleen scans, and 99mTc diethylenetriaminepentaacetic acid clearance glomerular filtration rates (GFRs) were obtained. Analysis of variance and the Student test were performed to compare sonographic findings to published results in healthy children and to clinical and laboratory findings. RESULTS The mean (± SD) spleen volume (108 ± 47 mL) was significantly greater than published normal control values (30 ± 14 mL; p < 0.0001). There was no correlation between spleen volume and function assessed by liver-spleen scan. The mean GFR (125 ± 34 mL/min/1.73 m2) was elevated compared with control GFRs (92 ± 18 mL/min/1.73 m2). Renal volumes (right kidney, 29 ± 8 mL; left kidney, 31 ± 9 mL) were significantly greater than control volumes (right kidney, 27 ± 3 mL; left kidney, 27 ± 3 mL; p < 0.0001) and were positively correlated with GFR (p = 0.0009). Five percent of patients had sonographic biliary abnormalities (sludge, n = 6; dilated common bile duct, n = 2; and cholelithiasis and thickened gallbladder wall, n = 1 each). There was no correlation between biliary sonographic findings and laboratory results. CONCLUSION
Desmoid tumors of the abdominal wall: A case report
Overhaus, Marcus; Decker, Pan; Fischer, Hans Peter; Textor, Hans Jochen; Hirner, Andreas
2003-01-01
Background Desmoid tumors are slow growing deep fibromatoses with aggressive infiltration of adjacent tissue but without any metastatic potential. Case Presentation We report on two female patients with desmoid tumor of the abdominal wall who underwent primary resection. Both patients had a history of an earlier abdominal surgery. Preoperative evaluation included abdominal ultrasound, magnetic resonance imaging and computed tomography. The histology in both cases revealed a desmoid tumor. Conclusion Complete surgical resection is the first line management of this tumor entity. PMID:12890284
Limited Abdominal Sonography for Evaluation of Children With Right Lower Quadrant Pain.
Munden, Martha M; Wai, Shannon; DiStefano, Michael C; Zhang, Wei
2017-01-01
To determine whether a complete abdominal sonographic examination is necessary in the evaluation of children with right lower quadrant pain that is suspicious for appendicitis in the emergency department and whether performing a limited, more-focused study would miss clinically important disease. With Institutional Review Board approval, a retrospective study was performed of 704 patients, from ages 5-19 years, presenting to the emergency department with right lower quadrant pain that was suspicious for appendicitis who underwent a complete abdominal sonographic examination. Data were extracted from the complete abdominal sonographic examination to see whether abnormalities were noted in the pancreas, spleen, and left kidney. Patients' medical charts were reviewed to see whether any positive findings in these organs were clinically important. Of the 65 studies with a finding that would have been missed with a limited study, only 6 were found to be clinically important. Of those, 5 were managed medically and 1 surgically. The chance of missing a potentially important finding using a limited study with our group of patients was 65 of 704 patients (9.2%), with a 95% confidence interval of 7.2% to 11.7%. The chance of missing an abnormality that was clinically important was 6 of 704 patients (0.85%), with a 95% confidence interval of 0.35% to 1.94%. In children older than 5 years with abdominal pain that is suspicious for appendicitis, performing only a limited abdominal sonographic examination that excludes the pancreas, left kidney, and spleen will yield a miss rate for clinically important disease that is acceptably low to justify the savings of examination time. © 2016 by the American Institute of Ultrasound in Medicine.
Iwashita, Takuji; Nakai, Yousuke; Lee, John G; Park, Do Hyun; Muthusamy, V Raman; Chang, Kenneth J
2012-02-01
Multiple diagnostic and therapeutic endoscopic ultrasound (EUS) procedures have been widely performed using a standard oblique-viewing (OV) curvilinear array (CLA) echoendoscope. Recently, a new, forward-viewing (FV) CLA was developed, with the advantages of improved endoscopic viewing and manipulation of devices. However, the FV-CLA echoendoscope has a narrower ultrasound scanning field, and lacks an elevator, which might represent obstacles for clinical use. The aim of this study was to compare the FV-CLA echoendoscope to the OV-CLA echoendoscope for EUS imaging of abdominal organs, and to assess the feasibility of EUS-guided interventions using the FV-CLA echoendoscope. EUS examinations were first performed and recorded using the OV-CLA echoendoscope, followed immediately by the FV-CLA echoendoscope. Video recordings were then assessed by two independent endosonographers in a blinded fashion. The EUS visualization and image quality of specific abdominal organs/structures were scored. Any indicated fine-needle aspiration (FNA) or intervention was performed using the FV-CLA echoendoscope, with the OV-CLA echoendoscope as salvage upon failure. A total of 21 patients were examined in the study. Both echoendoscopes had similar visualization and image quality for all organs/structures, except the common hepatic duct (CHD), which was seen significantly better with the FV-CLA echoendoscope. EUS interventions were conducted in eight patients, including FNA of pancreatic mass (3), pancreatic cyst (3), and cystgastrostomy (2). The FV-CLA echoendoscope was successful in seven patients. One failed FNA of the pancreatic head cyst was salvaged using the OV-CLA echoendoscope. There were no differences between the FV-CLA echoendoscope and the OV-CLA echoendoscope in visualization or image quality on upper EUS, except for the superior image quality of CHD using the FV-CLA echoendoscope. Therefore, the disadvantages of the FV-CLA echoendoscope appear minimal in light of the
Morchel, Herman; Ogedegbe, Chinwe; Chaplin, William; Cheney, Brianna; Zakharchenko, Svetlana; Misch, David; Schwartz, Matthew; Feldman, Joseph; Kaul, Sanjeev
2018-03-01
To determine if physicians trained in ultrasound interpretation perceive a difference in image quality and usefulness between Extended Focused Assessment with Sonography ultrasound examinations performed at bedside in a hospital vs. by emergency medical technicians minimally trained in medical ultrasound on a moving ambulance and transmitted to the hospital via a novel wireless system. In particular, we sought to demonstrate that useful images could be obtained from patients in less than optimal imaging conditions; that is, while they were in transport. Emergency medical technicians performed the examinations during transport of blunt trauma patients. Upon patient arrival at the hospital, a bedside Extended Focused Assessment with Sonography examination was performed by a physician. Both examinations were recorded and later reviewed by physicians trained in ultrasound interpretation. Data were collected on 20 blunt trauma patients over a period of 13 mo. Twenty ultrasound-trained physicians blindly compared transmitted vs. bedside images using 11 Questionnaire for User Interaction Satisfaction scales. Four paired samples t-tests were conducted to assess mean differences between ratings for ambulatory and base images. Although there is a slight tendency for the average rating across all subjects and raters to be slightly higher in the base than in the ambulatory condition, none of these differences are statistically significant. These results suggest that the quality of the ambulatory images was viewed as essentially as good as the quality of the base images.
NASA Astrophysics Data System (ADS)
Chang, Bingguo; Chen, Xiaofei
2018-05-01
Ultrasonography is an important examination for the diagnosis of chronic liver disease. The doctor gives the liver indicators and suggests the patient's condition according to the description of ultrasound report. With the rapid increase in the amount of data of ultrasound report, the workload of professional physician to manually distinguish ultrasound results significantly increases. In this paper, we use the spectral clustering method to cluster analysis of the description of the ultrasound report, and automatically generate the ultrasonic diagnostic diagnosis by machine learning. 110 groups ultrasound examination report of chronic liver disease were selected as test samples in this experiment, and the results were validated by spectral clustering and compared with k-means clustering algorithm. The results show that the accuracy of spectral clustering is 92.73%, which is higher than that of k-means clustering algorithm, which provides a powerful ultrasound-assisted diagnosis for patients with chronic liver disease.
Marchitelli, Giulia; Stirnemann, Julien; Acanfora, Marta Maddalena; Rousseau, Veronique; Salomon, Laurent J; Ville, Yves
2015-09-01
The aim of this study was to assess the diagnostic agreement between the prenatal diagnosis of intra-abdominal cystic lesions made by ultrasound examination and the postnatal diagnosis. We reviewed all consecutive cases referred for an anechoic abdominal cyst from 2009 to 2013. Prenatal ultrasound diagnosis was compared with postnatal diagnosis. Prenatal diagnosis was defined as 'correct' if a specific prenatal diagnosis or one of the possible diagnoses was confirmed postnatally, as 'not confirmed' if the postnatal examination revealed no abnormalities and as 'incorrect' if the postnatal diagnosis was different from those suggested prenatally. Seventy-three cases were included, and prenatal diagnoses were made at a median gestational age of 27 weeks (range: 13-36). Correct diagnoses were made in 66 cases (90.4%), including four in which the lesion resolved spontaneously in utero; two diagnoses were 'not confirmed' postnatally, and one was incorrect (a prenatal diagnosis of intestinal duplication was in fact an anorectal malformation). Postnatal diagnosis was not achieved in four cases: None of them required surgery, and clinical follow-up was favorable. The abdominal cysts were isolated in 52 cases (71%) and associated with other anomalies in 21 cases (29%). Aneuploidies were diagnosed in three cases (all trisomy 21). Eight cases underwent termination of pregnancy; there were no fetal deaths and one neonatal death. Postnatal surgery was performed in 30 out of 65 liveborn infants (46.1%). Overall diagnostic agreement between prenatal and postnatal diagnosis of fetal intra-abdominal cystic lesions is high. © 2015 John Wiley & Sons, Ltd.
Kirkpatrick, Andrew W; McKee, Ian; McKee, Jessica L; Ma, Irene; McBeth, Paul B; Roberts, Derek J; Wurster, Charles L; Parfitt, Robbie; Ball, Chad G; Oberg, Scott; Sevcik, William; Hamilton, Douglas R
2016-05-01
Remote-telementored ultrasound involves novice examiners being remotely guided by experts using informatic-technologies. However, requiring a novice to perform ultrasound is a cognitively demanding task exacerbated by unfamiliarity with ultrasound-machine controls. We incorporated a randomized evaluation of using remote control of the ultrasound functionality (knobology) within a study in which the images generated by distant naive examiners were viewed on an ultrasound graphic user interface (GUI) display viewed on laptop computers by mentors in different cities. Fire-fighters in Edmonton (101) were remotely mentored from Calgary (n = 65), Nanaimo (n = 19), and Memphis (n = 17) to examine an ultrasound phantom randomized to contain free fluid or not. Remote mentors (2 surgeons, 1 internist, and 1 ED physician) were randomly assigned to use GUI knobology control during mentoring (GUIK+/GUIK-). Remote-telementored ultrasound was feasible in all cases. Overall accuracy for fluid detection was 97% (confidence interval = 91 to 99%) with 3 false negatives (FNs). Positive/negative likelihood ratios were infinity/0.0625. One FN occurred with the GUIK+ and 2 without (GUIK-). There were no statistical test performance differences in either group (GUIK+ and GUIK-). Ultrasound-naive 1st responders can be remotely mentored with high accuracy, although providing basic remote control of the knobology did not affect outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.
An unusual cause of paediatric abdominal pain: Mesenteric masses accompanied with volvulus.
Yang, Chao; Wang, Shan; Zhang, Jun; Kong, Xiang Ru; Zhao, Zhenzhen; Li, Chang Chun
2016-07-01
Volvulus caused by mesenteric masses is rare and may result in serious consequences. This study aimed to better characterize volvulus caused by mesenteric masses in children. A retrospective study was conducted in 24 patients who underwent surgical treatment between January 1994 and January 2014 in one single institution. There were 10 boys and 14 girls. The most frequent findings were abdominal pain (100%), emesis (91.7%) and nausea (83.3%). Physical examination showed positive ileus signs in majority cases, and palpable mass was found in half of the patients. Ultrasound and CT scans revealed mesenteric masses in 21 and 24 patients, and 'whirlpool sign' was observed in 19 and 22 patients, respectively. Emergency laparotomy was performed in all patients. Histological examination revealed that 18 cystic masses were lymphangioma, 5 solid cases were lipoma and the remaining one was lipoblastoma. The postoperative course was uneventful in 22 patients, and postoperative obstruction and incision infection occurred in 2 patients. There was no evidence of recurrence at follow-up. Volvulus caused by mesenteric masses is a rare but potentially life-threatening cause of abdominal pain, which should be considered in the differential diagnosis of paediatric acute abdominal pain.
Ultrasound predictors of neonatal outcome in intrauterine growth restriction.
Craigo, S D; Beach, M L; Harvey-Wilkes, K B; D'Alton, M E
1996-11-01
Our purpose was to assess the value of commonly performed ultrasound parameters in predicting neonatal outcome of fetuses with intrauterine growth restriction (IUGR). One hundred twenty-seven patients were identified on ultrasound examination to have IUGR. Estimated weight percentile, amniotic fluid volume, umbilical artery Doppler velocimetry, and head circumference/abdominal circumference ratio were compared with neonatal outcome. Thirty infants had severely adverse courses. The degree of growth restriction was strongly associated with adverse outcome and neonatal death. Umbilical artery Doppler waveforms with absent or reverse end-diastolic flow were predicted of neonatal death, bronchopulmonary dysplasia (BPD), necrotizing enterocolitis (NEC), and adverse outcome in general. Oligohydramnios was predictive of adverse outcome and neonatal death. Logistic regression also showed that absent or reverse end-diastolic flow and oligohydramnios were independent predictors of adverse outcome. Ultrasound findings of low estimated weight percentile, absent or reverse end-diastolic umbilical blood flow, and oligohydramnios are independent predictors of adverse neonatal outcome of growth restricted fetuses.
Kordi, Ramin; Dehghani, Saeed; Noormohammadpour, Pardis; Rostami, Mohsen; Mansournia, Mohammad Ali
2015-01-01
The aim of this study was to compare the effect of diet and an abdominal resistance training program to diet alone on abdominal subcutaneous fat thickness and waist circumference of overweight and obese women. This randomized clinical trial included 40 overweight and obese women randomly divided into 2 groups: diet only and diet combined with 12 weeks of abdominal resistance training. Waist and hip circumferences and abdominal skin folds of the subjects were measured at the beginning and 12 weeks after the interventions. In addition, abdominal subcutaneous fat thickness of the subjects was measured using ultrasonography. Percentage body fat and lean body mass of all the subjects were also measured using a bioelectric impedance device. After 12 weeks of intervention, the weight of participants in both groups decreased; but the difference between the 2 groups was not significant (P = .45). Similarly, other variables including abdominal subcutaneous fat, waist circumference, hip circumference, body mass index, body fat percentage, and skin fold thickness were reduced in both groups; but there were no significant differences between the groups. This study found that abdominal resistance training besides diet did not reduce abdominal subcutaneous fat thickness compared to diet alone in overweight or obese women. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.
Abdominal aortic aneurysm screening program in Poland.
Jawien, A; Formankiewicz, B; Derezinski, T; Migdalski, A; Brazis, P; Woda, L
Screening for abdominal aortic aneurysms (AAA) is currently recommended by several vascular societies. In countries where it has been introduced the prevalence of AAAs differed greatly and was mainly related to cigarette smoking. The screening program also had an enormous impact on the decrease of AAA ruptures and reduced mortality rate. These facts have led to the introduction of the first screening program for AAAs in Poland. The aim of the study was to determine the prevalence of AAAs among men aged 60 years and older undergoing ultrasound examination of the abdominal aorta. A single ultrasonography of the abdomen was performed to assess the aorta from the renal arteries to the bifurcation and the diameter of the aorta was measured at its widest point. The cut-off value for determining an aortic aneurysm was set at a diameter of ≥ 30 mm. All ultrasonography measurements were performed by physicians in outpatient departments throughout the Kuyavian-Pomeranian Province. Additionally, each subject had to fill out a questionnaire with demographic data, smoking habits, existing comorbidities and familial occurrence of AAAs. The study was conducted from October 2009 to November 2011. The abdominal aorta ultrasound examinations were carried out in 1556 men aged 60 years and older. The prevalence of AAA in the study population was 6.0 % (94 out of 1556). The average age of the men was 69 years (SD 6 years, range 60-92 years). In the study population 55 % of the men smoked or had smoked and 3 % were aware of the presence of AAAs in family members. There were three risk factors significantly associated with the presence of AAAs: age (p < 0.05), smoking (72.3 % vs 53.9 %, p = 0.004) and family history of AAAs (9.6 % vs 2.7 %, p = 0.017). The prevalence of AAAs among men in Poland is higher than in other European countries and the USA. The screening program for AAAs is an easy and reliable method for detecting early stages of the disease and
Oh-Oka, Hitoshi; Nose, Ryuichiro
2005-09-01
Using a portable three dimensional ultrasound scanning device (The Bladder Scan BVI6100, Diagnostic Ultrasound Corporation), we examined measured values of bladder volume, especially focusing on volume lower than 100 ml. A total of 100 patients (male: 66, female: 34) were enrolled in the study. We made a comparison study between the measured value (the average of three measurements of bladder urine volume after a trial in male and female modes) using BVI6100, and the actual measured value of the sample obtained by urethral catheterization in each patient. We examined the factors which could increase the error rate. We also introduced the effective techniques to reduce measurement errors. The actual measured values in all patients correlated well with the average value of three measurements after a trial in a male mode of the BVI6100. The correlation coefficient was 0.887, the error rate was--4.6 +/- 24.5%, and the average coefficient of variation was 15.2. It was observed that the measurement result using the BVI6100 is influenced by patient side factors (extracted edges between bladder wall and urine, thickened bladder wall, irregular bladder wall, flattened rate of bladder, mistaking prostate for bladder in male, mistaking bladder for uterus in a female mode, etc.) or examiner side factors (angle between BVI and abdominal wall, compatibility between abdominal wall and ultrasound probe, controlling deflection while using probe, etc). When appropriate patients are chosen and proper measurement is performed, BVI6100 provides significantly higher accuracy in determining bladder volume, compared with existing abdominal ultrasound methods. BVI6100 is a convenient and extremely effective device also for the measurement of bladder urine over 100 ml.
[Ultrasound examination for lower extremity deep vein thrombosis].
Toyota, Kosaku
2014-09-01
Surgery is known to be a major risk factor of vein thrombosis. Progression from lower extremity deep vein thrombosis (DVT) to pulmonary embolism can lead to catastrophic outcome, although the incidence ratio is low. The ability to rule in or rule out DVT is becoming essential for anesthesiologists. Non-invasive technique of ultrasonography is a sensitive and specific tool for the assessment of lower extremity DVT. This article introduces the basics and practical methods of ultrasound examination for lower extremity DVT.
Ultrasound cavitation versus cryolipolysis for non-invasive body contouring.
Mahmoud ELdesoky, Mohamed Taher; Mohamed Abutaleb, Enas ELsayed; Mohamed Mousa, Gihan Samir
2015-08-24
The demand for non-surgical and non-invasive devices is continuous and increasing. Such devices have gradually gained ground in the reduction of localised fat and the improvement of body contouring. The study aimed to compare the effects of ultrasound cavitation and cryolipolysis on localised abdominal fat. In total, 60 participants with a body mass index (BMI) over 30 kg/m 2 , whose age ranged between 25 and 45 years, were included. The participants were randomly assigned to three groups of 20 each, using ultrasound cavitation and diet, cryolipolysis and diet, and diet only (the control group), respectively. Measures were bodyweight, BMI, waist circumference and suprailiac skinfold were measured at the beginning of the study and 2 months later. The three groups showed significant improvements in all measured variables after 2 months. There was no statistically significant difference in bodyweight or in BMI among the groups after treatment. However, the groups using ultrasound cavitation and cryolipolysis showed better post-treatment improvement than the diet-only group in waist circumference and suprailiac skinfold. There was no statistically significant difference post-treatment between the cavitation and cryolipolysis groups in waist circumference or suprailiac skinfold. Both ultrasound cavitation and cryolipolysis are safe and effective for the reduction of abdominal fat thickness and for abdominal contouring. © 2015 The Australasian College of Dermatologists.
Systemic mastocytosis: CT and US features of abdominal manifestations.
Avila, N A; Ling, A; Worobec, A S; Mican, J M; Metcalfe, D D
1997-02-01
To study the imaging findings in patients with systemic mastocytosis and to correlate the findings with the severity of disease on the basis of an established classification system. Pathologic findings, when available, were correlated with imaging findings. Computed tomographic (CT) and ultrasound (US) scans and corresponding pathologic findings, when available, were retrospectively reviewed in 27 patients with systemic mastocytosis. Only five (19%) of the patients in our series had normal abdominal CT and/or US examination results. Common abdominal imaging findings associated with systemic mastocytosis were hepatosplenomegaly, retroperitoneal adenopathy, periportal adenopathy, mesenteric adenopathy, thickening of the omentum and the mesentery, and ascites. Less common findings included hepatofugal portal venous flow, Budd-Chiari syndrome, cavernous transformation of the portal vein, ovarian mass, and complications such as chloroma. The findings were more common in patients with category II and those with category III disease. Abdominal findings at CT and US are common in patients with systemic mastocytosis. Although the findings in patients with systemic mastocytosis are not specific to the disease, they are useful in directing further studies for diagnostic confirmation and in estimating the extent of systemic involvement.
Suthar, Pokhraj Prakashchandra; Doshi, Rajkumar Prakashbhai; Mehta, Chetan; Vadera, Khyati P
2015-03-12
A 10-year-old child presented with dull aching periumbilical abdominal pain for 15 days. The child was not gaining weight despite a good appetite. Physical examination of the child revealed grade-I protein energy malnourishment (PEM) according to IAP (Indian Academic of Paediatrics) classification. The rest of the systemic examination was normal. Routine blood investigation revealed anaemia with eosinophilia. Abdominal ultrasonography did not show any abnormality with curvilinear transducer (3.5-5 MHz), however, linear ultrasound transducer (7.5-12 MHz) with harmonic tissue imaging showed worms in the lumen of the small intestine with curling movement on real time scanning. Stool examination for the eggs of ascariasis was positive. The patient was treated with antihelminthic drugs. Dietary modification for the PEM was advised. After 3 months of treatment, the patient improved and stool examination for Ascaris was negative on follow-up. 2015 BMJ Publishing Group Ltd.
Prevalence of uterine myoma detected by ultrasound examination in the atomic bomb survivors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kawamura, Sachiko; Kodama, Kazunori; Fujiwara, Saeko
1997-06-01
Benign tumors of several organs have been demonstrated to occur as late effects of atomic bomb exposure, and a recent addition to the list of affected organs in the uterus. The increased incidence of uterine myoma noted in Radiation Effects Research Foundation (REFR) Adult Health Study Report 7, however, was based on self-reported information, optional gynecological examination and patient-requested ultrasound examination. Thus the possibility of dose-related bias in case detection was a serious concern. Therefore, the relationship between the prevalence of uterine myoma and dose to the uterus was examined after excluding as much bias as possible by asking allmore » women who had undergone biennial examinations from December 1991 through December 1993 to undergo ultrasound examinations. Among 2506 female participants in Hiroshima, the uterus was visualized by ultrasound examination in 1190, and 238 were found to have uterine nodules. Multiple logistic analysis using Dosimetry System 1986 uterine doses revealed a significant dose response for the prevalence of uterine nodules. The odds ratio at 1 Gy was 1.61 (95% confidence interval: 1.12-2.31). It is unlikely that the observed relationship after adjusting for bladder filling, volume of the uterus, age and menopause status was the result of dose-related bias. These results support previous findings at RERF and provide further evidence that radiation exposure is one of the factors associated with uterine myoma. 28 refs., 3 figs., 4 tabs.« less
Usefulness of ultrasound examination in the evaluation of a neonate's body fluid status.
Kieliszczyk, Joanna; Baranowski, Wojciech; Kosiak, Wojciech
2016-06-01
Appropriate hydration is a very important prognostic factor for the patient's health. Ultrasonographic assessment of hydration status is rarely used in pediatric medicine and it is not used at all in neonates due to the fact that no reference values have been established for this age group. The aim of the paper was to establish reference values for neonates. The study included 50 neonates from two hospitals in the Lower Silesia region of Poland; 25 of them were healthy patients (full-term newborns with no perinatal complications) and 25 were sick patients (newborns with heart defects such as ostium secundum atrial septal defect, ventricular septal defect, permanent foramen ovale and patent ductus arteriosus as well as newborns with neonatal jaundice or pneumonia that occurred during the first days of life). The ultrasound scans were conducted during the first days of the children's life. For every child inferior vena cava diameter was measured in the substernal area, longitudinal plane, M-mode in two respiratory phases: inhalation and exhalation. In addition, abdominal aorta diameter was determined (substernal area, transverse plane). The study demonstrated a statistically significant difference in the calculated inferior vena cava collapsibility index between both groups. Two other indices included the ratio of the inferior vena cava diameter during the expiratory phase to the diameter of the aorta and the ratio of the inferior vena cava diameter during the inspiratory phase to the diameter of the aorta; a statistically significant difference between both groups was found only for the measurements in the inspiratory phase. Based on the study results normal ranges for hydration indices in neonates were established. The need for the measurement of the abovementioned parameters in the inspiratory phase was determined. In addition, the usefulness of the ultrasound examination for the evaluation of body fluid status in this pediatric age group, particularly in preterm
Defining the abdominal radiologist based on the current U.S. job market.
Hoffman, David H; Rosenkrantz, Andrew B
2018-03-24
The purpose of the study is to characterize current practice patterns of abdominal radiologists based on work descriptions within job postings on numerous national radiology specialty websites. Job postings for either "abdominal" or "body" radiologists were searched weekly on five society websites (SAR, SCBT-MR, ARRS, ACR, RSNA) over a 1-year period. Postings were reviewed for various characteristics. Nine hundred and sixteen total ads for 341 unique abdominal radiologist positions were reviewed (34.6% academic, 64.2% private practice, 1.2% other). Postings occurred most commonly in March (12.3%) and least commonly in November (4.8%). States with most positions were Florida (27), California (26), and New York (24). Of postings delineating expectations of specific abdominal modalities, 67.4% mentioned MRI, 58.5% ultrasound, 41.1% fluoroscopy, 14.3% PET, and 54.0% interventions. Additional non-abdominal expectations included general radiology (28.7%), breast imaging (21.1%), and general nuclear medicine (9.7%). Additional skills included prostate MRI (7.0%), OBGYN ultrasound (5.0%), and CT colonoscopy (2.6%). 79.2% required an abdominal imaging fellowship (specifically a body MRI fellowship in 4.1%). By using job postings for abdominal radiologists, we have taken a practical approach to characterizing the current status of this subspecialty, reflecting recent job expectations and requirements. The large majority of positions required a body fellowship, and the positions commonly entailed a variety of skills beyond non-invasive diagnostic abdominal imaging. Of note, expectations of considerable minorities of positions included abdominal interventions, general radiology, and breast imaging. These insights may guide the development of abdominal radiology fellowships and mini-fellowships, as well as assist radiologists entering or returning to the job market.
Chalouhi, Gihad E; Bernardi, Valeria; Gueneuc, Alexandra; Houssin, Isabelle; Stirnemann, Julien J; Ville, Yves
2016-04-01
Evaluation of trainee's ability in obstetrical ultrasound is a time-consuming process, which requires involving patients as volunteers. With the use of obstetrical ultrasound simulators, virtual reality could help in assessing competency and evaluating trainees in this field. The objective of the study was to test the validity of an obstetrical ultrasound simulator as a tool for evaluating trainees following structured training by comparing scores obtained on obstetrical ultrasound simulator with those obtained on volunteers and by assessing correlations between scores of images and of dexterity given by 2 blinded examiners. Trainees, taking the 2013 French national examination for the practice of obstetrical ultrasound were asked to obtain standardized ultrasound planes both on volunteer pregnant women and on an obstetrical ultrasound simulator. These planes included measurements of biparietal diameter, abdominal circumference, and femur length as well as reference planes for cardiac 4-chamber and outflow tracts, kidneys, stomach/diaphragm, spine, and face. Images were stored and evaluated subsequently by 2 national examiners who scored each picture according to previously established quality criteria. Dexterity was also evaluated and subjectively scored between 0 and 10. The Raghunathan's modification of Pearson, Filon's z, Spearman's rank correlation, and analysis of variance tests were used to assess correlations between the scores by the 2 examiners and scores of dexterity and also to compare the final scores between the 2 different methods. We evaluated 29 trainees. The mean dexterity scores in simulation (6.5 ± 2.0) and real examination (5.9 ± 2.3) were comparable (P = .31). Scores with an obstetrical ultrasound simulator were significantly higher than those obtained on volunteers (P = .027). Nevertheless, there was a good correlation between the scores of the 2 examiners judging on simulation (R = 0.888) and on volunteers (R = 0.873) (P = .81). An
FAST at MACH 20: clinical ultrasound aboard the International Space Station.
Sargsyan, Ashot E; Hamilton, Douglas R; Jones, Jeffrey A; Melton, Shannon; Whitson, Peggy A; Kirkpatrick, Andrew W; Martin, David; Dulchavsky, Scott A
2005-01-01
Focused assessment with sonography for trauma (FAST) examination has been proved accurate for diagnosing trauma when performed by nonradiologist physicians. Recent reports have suggested that nonphysicians also may be able to perform the FAST examination reliably. A multipurpose ultrasound system is installed on the International Space Station as a component of the Human Research Facility. Nonphysician crew members aboard the International Space Station receive modest training in hardware operation, sonographic techniques, and remotely guided scanning. This report documents the first FAST examination conducted in space, as part of the sustained effort to maintain the highest possible level of available medical care during long-duration space flight. An International Space Station crew member with minimal sonography training was remotely guided through a FAST examination by an ultrasound imaging expert from Mission Control Center using private real-time two-way audio and a private space-to-ground video downlink (7.5 frames/second). There was a 2-second satellite delay for both video and audio. To facilitate the real-time telemedical ultrasound examination, identical reference cards showing topologic reference points and hardware controls were available to both the crew member and the ground-based expert. A FAST examination, including four standard abdominal windows, was completed in approximately 5.5 minutes. Following commands from the Mission Control Center-based expert, the crew member acquired all target images without difficulty. The anatomic content and fidelity of the ultrasound video were excellent and would allow clinical decision making. It is possible to conduct a remotely guided FAST examination with excellent clinical results and speed, even with a significantly reduced video frame rate and a 2-second communication latency. A wider application of trauma ultrasound applications for remote medicine on earth appears to be possible and warranted.
Pollard, R E; Fuller, M C; Steffey, M A
2017-06-01
In this prospective study, we hypothesized that computed tomography (CT) would identify more normal and abnormal iliosacral lymph nodes (LNs) than abdominal ultrasound in dogs with anal sac gland carcinoma (ASGC). Twelve client-owned dogs with ASGC but without distant metastasis were enrolled. Abdominal ultrasound and contrast-enhanced CT scans of the abdomen were obtained. Iliosacral LNs were counted and assessed for location, laterality and size. Significantly (P < 0.00001) more iliosacral LNs were identified with CT (61) than ultrasound (30), including significantly (P = 0.00012) more medial iliac LNs with CT (33) than ultrasound (19). There was no difference in number of internal iliac LNs identified with CT versus ultrasound. Significantly (P = 0.000061) more sacral LNs were identified with CT (15) than ultrasound (0). Ultrasound identified slightly more (7) abnormal iliosacral LNs than CT (5). Contrast CT was able to identify more normal but not more abnormal LNs than ultrasound. © 2015 John Wiley & Sons Ltd.
Sheehan, Scott E; Coburn, John A; Singh, Hardeep; Vanness, David J; Sittig, Dean F; Moberg, D Paul; Safdar, Nasia; Lee, Kenneth S; Brunner, Michael C
2016-07-01
MRI is frequently overused. The aim of this study was to analyze shoulder MRI ordering practices within a capitated health care system and explore the potential effects of shoulder ultrasound substitution. We reviewed medical records of 237 consecutive shoulder MRI examinations performed in 2013 at a Department of Veterans Affairs tertiary care hospital. Using advanced imaging guidelines, we assessed ordering appropriateness of shoulder MRI and estimated the proportion of examinations for which musculoskeletal ultrasound could have been an acceptable substitute, had it been available. We then reviewed MRI findings and assessed if ultrasound with preceding radiograph would have been adequate for diagnosis, based on literature reports of shoulder ultrasound diagnostic performance. Of the 237 examinations reviewed, 106 (45%) were deemed to be inappropriately ordered, most commonly because of an absent preceding radiograph (n = 98; 92%). Nonorthopedic providers had a higher frequency of inappropriate ordering (44%) relative to orthopedic specialists (17%) (P = .016; odds ratio = 3.15, 95% confidence interval = 1.24-8.01). In the 237 examinations, ultrasound could have been the indicated advanced imaging modality for 157 (66%), and most of these (133/157; 85%) could have had all relevant pathologies characterized when combined with radiographs. Regardless of indicated modality, ultrasound could have characterized 80% of all cases ordered by nonorthopedic providers and 50% of cases ordered by orthopedic specialists (P = .007). Advanced shoulder imaging is often not ordered according to published appropriateness criteria. While nonorthopedic provider orders were more likely to be inappropriate, inappropriateness persisted among orthopedic providers. A combined ultrasound and radiograph evaluation strategy could accurately characterize shoulder pathologies for most cases. Published by Elsevier Inc.
van der Ven, Myrthe; Karreman, Maren C; Weel, Angelique E A M; Tchetverikov, Ilja; Vis, Marijn; Nijsten, Tamar E C; Hazes, Johanna M W; Luime, Jolanda J
2016-01-01
Part of the psoriasis patients with musculoskeletal complaints will have inflammation of the entheses. Entheseal inflammation is difficult to assess by clinical examination only. Therefore, we aimed to determine the frequency of clinically relevant ultrasound inflammation at the most commonly assessed entheses (MASEI; Madrid Sonographic Enthesis Index) in primary care psoriasis patients with one or more tender entheses. Adult primary care psoriasis patients with musculoskeletal complaints (tender enthesis or arthritis at physical examination) had an ultrasound examination of seven entheses according to the MASEI. Clinically relevant ultrasound inflammation was defined as active inflammation on ultrasound in combination with at least one clinical feature at the same enthesis. Active ultrasound inflammation contained positive power Doppler signal or in case of the plantar aponeurosis increased thickness. Structural changes entailed calcifications, enthesophytes, increased thickness, hypoechogeneicity indicating irregular fibre structure and erosions. Clinically, an enthesis was scored positive by a tender enthesis at clinical examination, reported pain in the history or self-reported pain in the questionnaires. Of 542 primary care psoriasis patient, 111 patients had tender entheses and/or arthritis. These patients were both clinically and ultrasonographically evaluated. Active ultrasound inflammation accompanied with pain or tenderness at the enthesis was found in 36% of the patients (n=40). Most common were inflammation at the knee (n=11) and at the plantar aponeurosis (n=10). Structural changes were observed in 95% of the psoriasis patients independent of their clinical manifestation. We found concurrent presence of ultrasound inflammatory changes and clinical symptoms in 36% of the primary care psoriasis patients who had tenderness at one or more entheseal sites.
Zhang, Zhongheng; Hong, Yucai; Liu, Ning; Chen, Yuhao
2017-06-30
We aimed to investigate the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) in evaluating blunt abdominal trauma for patients presenting to the emergency department. Electronic search of Scopus and Pubmed was performed from inception to September 2016. Human studies investigating the diagnostic accuracy of CEUS in identifying abdominal solid organ injuries were included. Risk of bias was assessed using the QUADAS tool. A total of 10 studies were included in the study and 9 of them were included for meta-analysis. The log(DOR) values ranged from 3.80 (95% CI: 2.81-4.79) to 8.52 (95% CI: 4.58-12.47) in component studies. The combined log(DOR) was 6.56 (95% CI: 5.66-7.45). The Cochran's Q was 11.265 (p = 0.793 with 16 degrees of freedom), and the Higgins' I 2 was 0%. The CEUS had a sensitivity of 0.981 (95% CI: 0.868-0.950) and a false positive rate of 0.018 (95% CI: 0.010-0.032) for identifying parenchymal injuries, with an AUC of 0.984. CEUS performed at emergency department had good diagnostic accuracy in identifying abdominal solid organ injuries. CEUS can be recommended in monitoring solid organ injuries, especially for patients managed with non-operative strategy.
Jezewski, Janusz; Wrobel, Janusz; Matonia, Adam; Horoba, Krzysztof; Martinek, Radek; Kupka, Tomasz; Jezewski, Michal
2017-01-01
the acquisition method. The obtained results prove that the abdominal FECG, considered as an alternative to the ultrasound approach, does not change the interpretation of the FHR signal, which was confirmed during both visual assessment and automated analysis. PMID:28559852
Ülker, Kahraman; Akyer, Şahika P; Temur, İsmail; Tan, Temel; Karaca, Mehmet; Adıgüzel, Esat; Gül, Abdülaziz
2012-02-01
Parapagus (laterally fused), diprosopus (two faces), dibrachius (two upper extremities), dipus (two lower extremities) conjoined twinning is extremely rare. The coexistence of anencephaly with a contiguous spinal defect (craniorachischisis totalis) makes the present case one of the rarest of the published cases. In our case, it was difficult to make the final diagnosis by two-dimensional abdominal and vaginal ultrasound. Three-dimensional ultrasound was helpful for final diagnosis and post-abortal examination confirmed the prenatal ultrasound diagnosis. The heart, diaphragm, liver and perineum were all united. Fine dissection of the heart showed four vessels arising from the ventricles and a membranous type ventricular septal defect. © 2011 The Authors. Journal of Obstetrics and Gynaecology Research © 2011 Japan Society of Obstetrics and Gynecology.
ASSOCIATIONS BETWEEN ULTRASOUND AND CLINICAL FINDINGS IN 87 CATS WITH URETHRAL OBSTRUCTION.
Nevins, Jonathan R; Mai, Wilfried; Thomas, Emily
2015-01-01
Urethral obstruction is a life-threatening form of feline lower urinary tract disease. Ultrasonographic risk factors for reobstruction have not been previously reported. Purposes of this retrospective cross-sectional study were to describe urinary tract ultrasound findings in cats following acute urethral obstruction and determine whether ultrasound findings were associated with reobstruction. Inclusion criteria were a physical examination and history consistent with urethral obstruction, an abdominal ultrasound including a full evaluation of the urinary system within 24 h of hospitalization, and no cystocentesis prior to ultrasound examination. Medical records for included cats were reviewed and presence of azotemia, hyperkalemia, positive urine culture, and duration of hospitalization were recorded. For medically treated cats with available outcome data, presence of reobstruction was also recorded. Ultrasound images were reviewed and urinary tract characteristics were recorded. A total of 87 cats met inclusion criteria. Common ultrasound findings for the bladder included echogenic urine sediment, bladder wall thickening, pericystic effusion, hyperechoic pericystic fat, and increased urinary echoes; and for the kidneys/ureters included pyelectasia, renomegaly, perirenal effusion, hyperechoic perirenal fat, and ureteral dilation. Six-month postdischarge outcomes were available for 61 medically treated cats and 21 of these cats had reobstruction. No findings were associated with an increased risk of reobstruction. Ultrasonographic perirenal effusion was associated with severe hyperkalemia (P = 0.009, relative risk 5.75, 95% confidence interval [1.54-21.51]). Findings supported the use of ultrasound as an adjunct for treatment planning in cats presented with urethral obstruction but not as a method for predicting risk of reobstruction. © 2015 American College of Veterinary Radiology.
Fraquelli, Mirella; Baccarin, Alessandra; Corti, Fabiola; Conti, Clara Benedetta; Russo, Maria Chiara; Della Valle, Serena; Pozzi, Roberta; Cressoni, Massimo; Conte, Dario; Colombo, Carla
2016-03-01
Ultrasound imaging is used to assess bowel abnormalities in gastrointestinal diseases. We aimed to assess the rate of predefined bowel ultrasound signs and their relationship with gastrointestinal symptoms and the cystic fibrosis transmembrane conductance regulator (CFTR) genotype in cystic fibrosis patients in regular follow-up. Prospective study of 70 consecutive patients with cystic fibrosis and 45 controls who underwent abdominal ultrasound; pertinent findings were related to gastrointestinal symptoms and, in cystic fibrosis patients, to pancreatic status, malabsorption degree, lipase intake, CFTR genotype (classified as severe or mild against functional class of CFTR mutations). 96% patients showed at least one abnormal bowel ultrasound sign. Most frequent signs were lymph node enlargement (64%), bowel loop dilatation (55%), thick corpuscular intraluminal content (49%), bowel wall hypervascularization (26%), thickened bowel wall (22%) and intussusception (17%). Patients with recurrent abdominal pain showed more bowel wall hypervascularization than patients without recurrent pain (47% vs. 19%, respectively; p = 0.02) and intussusception (58% vs. 17%, respectively; p < 0.01). Genotype was not associated to specific bowel ultrasound signs. Patients with bowel loop intussusception showed greater lipase intake than those without intussusception (8.118 ± 2.083 vs. 5.994 ± 4.187, respectively; p < 0.01). Cystic fibrosis patients present a higher rate of bowel ultrasound abnormalities than controls. Bowel ultrasound abnormalities are associated with abdominal symptoms. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
How to set up a low cost tele-ultrasound capable videoconferencing system with wide applicability
2012-01-01
Background Worldwide ultrasound equipment accessibility is at an all-time high, as technology improves and costs decrease. Ensuring that patients benefit from more accurate resuscitation and diagnoses from a user-dependent technology, such as ultrasound, requires accurate examination, typically entailing significant training. Remote tele-mentored ultrasound (RTUS) examination is, however, a technique pioneered in space medicine that has increased applicability on earth. We, thus, sought to create and demonstrate a cost-minimal approach and system with potentially global applicability. Methods The cost-minimal RTUS system was constructed by utilizing a standard off-the-shelf laptop computer that connected to the internet through an internal wireless receiver and/or was tethered through a smartphone. A number of portable hand-held ultrasound devices were digitally streamed into the laptop utilizing a video converter. Both the ultrasound video and the output of a head-mounted video camera were transmitted over freely available Voice Over Internet Protocol (VOIP) software to remote experts who could receive and communicate using any mobile device (computer, tablet, or smartphone) that could access secure VOIP transmissions from the internet. Results The RTUS system allowed real-time mentored tele-ultrasound to be conducted from a variety of settings that were inside buildings, outside on mountainsides, and even within aircraft in flight all unified by the simple capability of receiving and transmitting VOIP transmissions. . Numerous types of ultrasound examinations were conducted such as abdominal and thoracic examinations with a variety of users mentored who had previous skills ranging from none to expert. Internet connectivity was rarely a limiting factor, with competing logistical and scheduling demands of the participants predominating. Conclusions RTUS examinations can educate and guide point of care clinical providers to enhance their use of ultrasound. The scope
Fritz, Deborah; Weilitz, Pamela Becker
2016-03-01
Abdominal pain is one of the most common complaints by patients, and assessment of abdominal pain and associated symptoms can be challenging for home healthcare providers. Reasons for abdominal pain are related to inflammation, organ distention, and ischemia. The history and physical examination are important to narrow the source of acute or chronic problems, identify immediate interventions, and when necessary, facilitate emergency department care.
Boniface, Keith S; Shokoohi, Hamid; Smith, E Reed; Scantlebury, Kari
2011-06-01
The aim of this study was to examine the capability of ultrasound-naïve paramedics to obtain interpretable Focused Assessment With Sonography for Trauma (FAST) images under the remote direction of emergency physicians (EPs). Paramedics without experience using ultrasound participated in a 20-minute lecture covering orientation to the ultrasound machine and the FAST examination. The paramedics subsequently performed FAST examinations on a model patient, whereas the EP remained in another room, out of visual contact. The EP communicated with the paramedic via radio, viewing video from the ultrasound machine on a monitor and directing the probe movements to obtain the views of the FAST examination. We examined the success rate, time to complete the examinations, and adequacy of images from the paramedics' first FAST examination. Fifty-one paramedics performed their first FAST examinations and were able to successfully complete 100% of the views of the FAST. The median time from probe placement to examination completion was 262 seconds (interquartile range, 206-343 seconds). The median time to complete right upper quadrant (RUQ) versus left upper quadrant (LUQ) views was 39 and 50 seconds, respectively. The time to complete the LUQ scan took significantly longer than the RUQ (P < .01). Paramedics completed cardiac and pelvic view in a median time of 42 and 25 seconds, respectively. The study demonstrated that paramedics with no prior ultrasound experience could obtain FAST images under remote guidance from experienced EPs in less than 5 minutes. Given rapidly evolving data transmission technology, this has applicability in battlefield, remote, and rural prehospital settings. Copyright © 2011 Elsevier Inc. All rights reserved.
BMI, total and abdominal fat distribution, and cardiovascular risk factors in school-age children.
Gishti, Olta; Gaillard, Romy; Durmus, Busra; Abrahamse, Marieke; van der Beek, Eline M; Hofman, Albert; Franco, Oscar H; de Jonge, Layla L; Jaddoe, Vincent W V
2015-05-01
More specific total body and abdominal fat mass measures might be stronger associated with cardiovascular risk factors in childhood, than BMI. We examined the independent associations of total and abdominal fat measures with cardiovascular risk factors in school age children. We performed a population-based cohort study among 6,523 children. At the age of 6 y, we measured childhood BMI, and general and abdominal fat mass, using dual-energy X-ray absorptiometry, and ultrasound and cardiovascular risk factors. Conditional on BMI, higher fat mass percentage and abdominal fat mass were associated with higher blood pressure, total- and low-density lipoprotein (LDL)-cholesterol, insulin and c-peptide levels, but with lower left ventricular mass and high-density lipoprotein (HDL)-cholesterol (P values < 0.05). These associations differed between underweight, normal weight, overweight, and obese children. Higher childhood adiposity measures were associated with increased odds of cardiovascular risk factors clustering, with the strongest effect for fat mass percentage (odds ratios: 3.01 (95% confidence interval: 2.67, 3.9). Our results suggest that general and abdominal fat measures are associated with cardiovascular risk factors in childhood, independent from BMI. These measures may provide additional information for identification of children with an adverse cardiovascular profile.
Lisciandro, Gregory R; Fosgate, Geoffrey T; Fulton, Robert M
2014-01-01
Lung ultrasound is superior to lung auscultation and supine chest radiography for many respiratory conditions in human patients. Ultrasound diagnoses are based on easily learned patterns of sonographic findings and artifacts in standardized images. By applying the wet lung (ultrasound lung rockets or B-lines, representing interstitial edema) versus dry lung (A-lines with a glide sign) concept many respiratory conditions can be diagnosed or excluded. The ultrasound probe can be used as a visual stethoscope for the evaluation of human lungs because dry artifacts (A-lines with a glide sign) predominate over wet artifacts (ultrasound lung rockets or B-lines). However, the frequency and number of wet lung ultrasound artifacts in dogs with radiographically normal lungs is unknown. Thus, the primary objective was to determine the baseline frequency and number of ultrasound lung rockets in dogs without clinical signs of respiratory disease and with radiographically normal lung findings using an 8-view novel regionally based lung ultrasound examination called Vet BLUE. Frequency of ultrasound lung rockets were statistically compared based on signalment, body condition score, investigator, and reasons for radiography. Ten left-sided heart failure dogs were similarly enrolled. Overall frequency of ultrasound lung rockets was 11% (95% confidence interval, 6-19%) in dogs without respiratory disease versus 100% (95% confidence interval, 74-100%) in those with left-sided heart failure. The low frequency and number of ultrasound lung rockets observed in dogs without respiratory disease and with radiographically normal lungs suggests that Vet BLUE will be clinically useful for the identification of canine respiratory conditions. © 2014 American College of Veterinary Radiology.
Endoscopic ultrasound elastography: Current status and future perspectives
Cui, Xin-Wu; Chang, Jian-Min; Kan, Quan-Cheng; Chiorean, Liliana; Ignee, Andre; Dietrich, Christoph F
2015-01-01
Elastography is a new ultrasound modality that provides images and measurements related to tissue stiffness. Endoscopic ultrasound (EUS) has played an important role in the diagnosis and management of numerous abdominal and mediastinal diseases. Elastography by means of EUS examination can assess the elasticity of tumors in the proximity of the digestive tract that are hard to reach with conventional transcutaneous ultrasound probes, such as pancreatic masses and mediastinal or abdominal lymph nodes, thus improving the diagnostic yield of the procedure. Results from previous studies have promised benefits for EUS elastography in the differential diagnosis of lymph nodes, as well as for assessing masses with pancreatic or gastrointestinal (GI) tract locations. It is important to mention that EUS elastography is not considered a modality that can replace biopsy. However, it may be a useful adjunct, improving the accuracy of EUS-fine needle aspiration biopsy (EUS-FNAB) by selecting the most suspicious area to be targeted. Even more, it may be useful for guiding further clinical management when EUS-FNAB is negative or inconclusive. In the present paper we will discuss the current knowledge of EUS elastography, including the technical aspects, along with its applications in the differential diagnosis between benign and malignant solid pancreatic masses and lymph nodes, as well as its aid in the differentiation between normal pancreatic tissues and chronic pancreatitis. Moreover, the emergent indication and future perspectives are summarized, such as the benefit of EUS elastography in EUS-guided fine needle aspiration biopsy, and its uses for characterization of lesions in liver, biliary tract, adrenal glands and GI tract. PMID:26715804
Ekelin, M; Crang Svalenius, E; Larsson, A-K; Nyberg, P; Marsál, K; Dykes, A-K
2009-10-01
To investigate parents' expectations, experiences and reactions, sense of coherence and anxiety before and after a second-trimester routine ultrasound examination, with normal findings. Before and after ultrasound questionnaires including the scales parents' expectations, experiences and reactions to routine ultrasound examination (PEER-U state of mind index), sense of coherence (SOC) and state and trait anxiety inventory (STAI), were sent to a 1-year cohort of women and their partners. Replies received were 2183. Both parents had significantly less worried state of mind (PEER-U) after the examination than before. Women had a lower grade of state anxiety after than before, but for men there was no significant change. Before the ultrasound, women had a higher degree of worried state of mind, as well as a higher grade of state and trait anxiety and a lower sense of coherence, than men. The women showed a greater reduction in worried state of mind than the men after the ultrasound examination. There were no significant differences in sense of coherence before and after ultrasound. Women and men are affected in their psychological well-being in relation to a routine ultrasound examination, but their sense of coherence remains stable.
Diagnostic examination of the child with urolithiasis or nephrocalcinosis.
Hoppe, Bernd; Kemper, Markus J
2010-03-01
Urolithiasis and nephrocalcinosis are more frequent in children then currently anticipated, but still remain under- or misdiagnosed in a significant proportion of patients, since symptoms and signs may be subtle or misleading. All children with colicky abdominal pain or macroscopic hematuria should be examined thoroughly for urolithiasis. Also, other, more general, abdominal manifestations can be the first symptoms of renal stones. The patients and their family histories, as well as physical examination, are important initial steps for diagnostic evaluation. Thereafter, diagnostic imaging should be aimed at the location of calculi but also at identification of urinary tract anomalies or acute obstruction due to stone disease. This can often be accomplished by ultrasound examination alone, but sometimes radiological methods such as plain abdominal films or more sensitive non-enhanced computed tomography are necessary. Since metabolic causes are frequent in children, diagnostic evaluation should be meticulous so that metabolic disorders that cause recurrent urolithiasis or even renal failure, such as the primary hyperoxalurias and others, can be ruled out. The stone is not the disease itself; it is only one serious sign! Therefore, thorough and early diagnostic examination is mandatory for every infant and child with the first stone event, or with nephrocalcinosis.
Bani, Daniele; Quattrini Li, Alessandro; Freschi, Giancarlo; Russo, Giulia Lo
2013-09-01
In aesthetic medicine, the most promising techniques for noninvasive body sculpturing purposes are based on ultrasound-induced fat cavitation. Liporeductive ultrasound devices afford clinically relevant subcutaneous fat pad reduction without significant adverse reactions. This study aims at evaluating the histological and ultrastructural changes induced by ultrasound cavitation on the different cell components of human skin. Control and ultrasound-treated ex vivo abdominal full-thickness skin samples and skin biopsies from patients pretreated with or without ultrasound cavitation were studied histologically, morphometrically, and ultrastructurally to evaluate possible changes in adipocyte size and morphology. Adipocyte apoptosis and triglyceride release were also assayed. Clinical evaluation of the effects of 4 weekly ultrasound vs sham treatments was performed by plicometry. Compared with the sham-treated control samples, ultrasound cavitation induced a statistically significant reduction in the size of the adipocytes (P < 0.001), the appearance of micropores and triglyceride leakage and release in the conditioned medium (P < 0.05 at 15 min), or adipose tissue interstitium, without appreciable changes in microvascular, stromal, and epidermal components and in the number of apoptotic adipocytes. Clinically, the ultrasound treatment caused a significant reduction of abdominal fat. This study further strengthens the current notion that noninvasive transcutaneous ultrasound cavitation is a promising and safe technology for localized reduction of fat and provides experimental evidence for its specific mechanism of action on the adipocytes.
2014-01-01
Background Ultrasonography is an important diagnostic tool in the investigation of abdominal disease in the horse. Several factors may affect the ability to image different structures within the abdomen. The aim of the study was to describe the repeatability of identification of abdominal structures in normal horses using a detailed ultrasonographic examination technique and using a focused, limited preparation technique. Methods A detailed abdominal ultrasound examination was performed in five normal horses, repeated on five occasions (total of 25 examinations). The abdomen was divided into ten different imaging sites, and structures identified in each site were recorded. Five imaging sites were then selected for a single focused ultrasound examination in 20 normal horses. Limited patient preparation was performed. Structures were recorded as ‘identified’ if ultrasonographic features could be distinguished. The location of organs and their frequency of identification were recorded. Data from both phases were analysed to determine repeatability of identification of structures in each examination (irrespective of imaging site), and for each imaging site. Results Caecum, colon, spleen, liver and right kidney were repeatably identified using the detailed technique, and had defined locations. Large colon and right kidney were identified in 100% of examinations with both techniques. Liver, spleen, caecum, duodenum and other small intestine were identified more frequently with the detailed examination. Small intestine was most frequently identified in the ventral abdomen, its identification varied markedly within and between horses, and required repeated examinations in some horses. Left kidney could not be identified in every horse using either technique. Sacculated colon was identified in all ventral sites, and was infrequently identified in dorsal sites. Conclusions Caecum, sacculated large intestine, spleen, liver and right kidney were consistently identified
Walrod, Bryant J; Schroeder, Allison; Conroy, Mark J; Boucher, Laura C; Bockbrader, Marcia; Way, David P; McCamey, Kendra L; Hartz, Clinton A; Jonesco, Michael A; Bahner, David P
2018-01-01
Ultrasound imaging is commonly used to teach basic anatomy to medical students. The purpose of this study was to determine whether learning musculoskeletal anatomy with ultrasound improved performance on medical students' musculoskeletal physical examination skills. Twenty-seven first-year medical students were randomly assigned to 1 of 2 instructional groups: either shoulder or knee. Both groups received a lecture followed by hands-on ultrasound scanning on live human models of the assigned joint. After instruction, students were assessed on their ability to accurately palpate 4 anatomic landmarks: the acromioclavicular joint, the proximal long-head biceps tendon, and the medial and lateral joint lines of the knee. Performance scores were based on both accuracy and time. A total physical examination performance score was derived for each joint. Scores for instructional groups were compared by a 2-way analysis of variance with 1 repeated measure. Significant findings were further analyzed with post hoc tests. All students performed significantly better on the knee examination, irrespective of instructional group (F = 14.9; df = 1.25; P = .001). Moreover, the shoulder instruction group performed significantly better than the knee group on the overall assessment (t = -3.0; df = 25; P < .01). Post hoc analyses revealed that differences in group performance were due to the shoulder group's higher scores on palpation of the biceps tendon (t = -2.8; df = 25; P = .01), a soft tissue landmark. Both groups performed similarly on palpation of all other anatomic structures. The use of ultrasound appears to provide an educational advantage when learning musculoskeletal physical examination of soft tissue landmarks. © 2017 by the American Institute of Ultrasound in Medicine.
Vogelezang, S; Gishti, O; Felix, J F; van der Beek, E M; Abrahamse-Berkeveld, M; Hofman, A; Gaillard, R; Jaddoe, V W V
2016-04-01
Overweight and obesity in early life tends to track into later life. Not much is known about tracking of abdominal fat. Our objective was to examine the extent of tracking of abdominal fat measures during the first six years of life. We performed a prospective cohort study among 393 Dutch children followed from the age of 2 years (90% range 1.9; 2.3) until the age of 6 years (90% range 5.7; 6.2). At both ages, we performed abdominal ultrasound to measure abdominal subcutaneous and preperitoneal fat distances and areas, and we calculated the preperitoneal/subcutaneous fat distance ratio. High abdominal fat measures were defined as values in the upper 15%. Abdominal subcutaneous fat distance and area, and preperitoneal fat area at 2 years were correlated with their corresponding measures at 6 years (all P-values <0.01), with the strongest coefficients for abdominal subcutaneous fat measures. Preperitoneal fat distance at the age of 2 years was not correlated with the corresponding measure at 6 years. The tracking coefficient for preperitoneal/subcutaneous fat distance ratio from 2 to 6 years was r=0.36 (P<0.01). Children with high abdominal subcutaneous fat measures at 2 years had increased risk of having high abdominal subcutaneous fat measures at 6 years (odds ratios 9.2 (95% confidence interval (CI) 4.1-20.8) and 12.4 (95% CI 5.4-28.6) for subcutaneous fat distance and area, respectively). These associations were not observed for preperitoneal fat measures. Our findings suggest that both abdominal subcutaneous and preperitoneal fat mass measures track during childhood, but with stronger tracking for abdominal subcutaneous fat measures. An adverse abdominal fat distribution in early life may have long-term consequences.
Rostami, Mohsen; Noormohammadpour, Pardis; Mansournia, Mohammad Ali; Hantoushzadeh, Sedigheh; Farahbakhsh, Farzin; Nourian, Ruhollah; Kordi, Ramin
2015-05-01
To compare the thickness of the external oblique, internal oblique, and transversus abdominis muscles in pregnant subjects with and without low back pain (LBP) by the use of ultrasound to measure thickness. A case-control study. An academic and tertiary care referral spine and sports medicine center. Fifty pregnant women with LBP during pregnancy and 54 pregnant control subjects. Case and control subjects were matched for body mass index, gestational age, and number of previous pregnancies. A multiple linear regression model with adjustment for the gestational age of the subjects, as the potential confounder of the primary outcomes, was used to evaluate the association between LBP appearance and abdominal muscles thickness of the subjects. The thickness of lateral abdominal muscles was measured by ultrasound with the subject in a hook-lying position on the examination table. We found that there was no significant difference between pregnant subjects with and without LBP in terms of the thickness of external oblique, internal oblique, and transversus abdominis muscles. These findings suggest that other factors rather than the thickness of core stabilizing muscles are influential in the etiology of LBP during pregnancy. We hypothesize that enlargement of uterus during pregnancy might influence the thickness of the lateral abdominal muscles. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Grimes, Janet A; Scott, Katherine D; Edwards, John F
2016-01-01
A 2-year-old Dachshund was presented for vomiting and diarrhea. Abdominal ultrasound revealed Dirofilaria immitis in the abdominal aorta and an avascular segment of small intestine. The dog was euthanized. Necropsy revealed D. immitis in the abdominal aorta and widespread necrotizing arteriolitis. This is a unique presentation of aberrant migration of D. immitis.
Examining Neosho madtom reproductive biology using ultrasound and artificial photothermal cycles
Bryan, J.L.; Wildhaber, M.L.; Noltie, Douglas B.
2005-01-01
We examined whether extended laboratory simulation of natural photothermal conditions could stimulate reproduction in the Neosho madtom Noturus placidus, a federally threatened species. For 3 years, a captive population of Neosho madtoms was maintained under simulated natural conditions and monitored routinely with ultrasound for reproductive condition. Female Neosho madtoms cycled in and out of spawning condition, producing and absorbing oocytes annually. Internal measurements made by means of ultrasound indicated the summer mean oocyte size remained consistent over the years, although estimated fecundity increased with increasing fish length. In the summer of 2001, after 3 years in the simulated natural environment, 13 out of 41 fish participated in 10 spawnings. Simulation of the natural photothermal environment, coupled with within-day temperature fluctuations during the spring rise, seemed important for the spawning of captive Neosho madtoms. The use of ultrasound to assess the reproductive status in Neosho madtoms was effective and resulted in negligible stress or injury to the fish. These procedures may facilitate future culture of this species and other madtoms Noturus spp., especially when species are rare, threatened, or endangered. ?? Copyright by the American Fisheries Society 2005.
Coleman, William P; Coleman, William; Weiss, Robert A; Kenkel, Jeffrey M; Ad-El, Dean D; Amir, Ruthie
2017-01-01
Demand for nonsurgical esthetic body procedures has led to the development of noninvasive techniques for reducing localized subcutaneous adipose tissue. This study assessed multiple treatments with nonthermal focused ultrasound for noninvasive abdominal treatment of excess fat deposits. Subjects were randomly assigned to Group 1 for a 4-week control phase before undergoing 3 abdominal fat reduction treatments, at 2-week intervals, or to Group 2 for immediate treatment. Weight, abdominal circumference, tolerability to treatment, subject satisfaction, and adverse events were recorded. Weight remained stable in the 126 participants. Mean reduction in midline circumference was 2.5 ± 2.1 cm in the Group 1 and 3.5 ± 2.7 cm in the Group 2 at Week 22. The effect of multiple treatments was cumulative with a steady decrease in abdominal circumferences during the study. Erythema was observed in 28% of treatments but was mild and transient in nature. Subjects tolerated the treatments well and were satisfied with treatment outcome. The study demonstrated the efficacy and safety of multiple nonthermal focused ultrasound treatments of excess abdominal fat deposits. Although the remodeling effect is minor compared with traditional surgical procedures, successive focused ultrasound treatments significantly reduced treatment area circumference, while avoiding invasive techniques and their associated disadvantages.
Motion tracing system for ultrasound guided HIFU
NASA Astrophysics Data System (ADS)
Xiao, Xu; Jiang, Tingyi; Corner, George; Huang, Zhihong
2017-03-01
One main limitation in HIFU treatment is the abdominal movement in liver and kidney caused by respiration. The study has set up a tracking model which mainly compromises of a target carrying box and a motion driving balloon. A real-time B-mode ultrasound guidance method suitable for tracking of the abdominal organ motion in 2D was established and tested. For the setup, the phantoms mimicking moving organs are carefully prepared with agar surrounding round-shaped egg-white as the target of focused ultrasound ablation. Physiological phantoms and animal tissues are driven moving reciprocally along the main axial direction of the ultrasound image probe with slightly motion perpendicular to the axial direction. The moving speed and range could be adjusted by controlling the inflation and deflation speed and amount of the balloon driven by a medical ventilator. A 6-DOF robotic arm was used to position the focused ultrasound transducer. The overall system was trying to estimate to simulate the actual movement caused by human respiration. HIFU ablation experiments using phantoms and animal organs were conducted to test the tracking effect. Ultrasound strain elastography was used to post estimate the efficiency of the tracking algorithms and system. In moving state, the axial size of the lesion (perpendicular to the movement direction) are averagely 4mm, which is one third larger than the lesion got when the target was not moving. This presents the possibility of developing a low-cost real-time method of tracking organ motion during HIFU treatment in liver or kidney.
Aksu, Recep; Patmano, Gülçin; Biçer, Cihangir; Emek, Ertan; Çoruh, Aliye Esmaoğlu
We aimed to evaluate the effect of bupivacaine and dexmedetomidine added to bupivacaine used in tranversus abdominis plane (TAP) block on postoperative pain and patient satisfaction in patients undergoing lower abdominal surgery. Patients submitted to lower abdominal surgery were enrolled in the study. After anesthesia induction, ultrasound guided TAP block was performed. TAP block was obtained with 21mL 0.9% saline in Group C (n=31), 20mL 0.5% bupivacaine+1mL saline in Group B (n=31), and 20mL 0.5% bupivacaine+1mL dexmedetomidine (100μg) in Group BD (n=31). Visual analog scale scores were lower in Group BD compared to Group C, at all time points (p<0.05); it was lower in group BD than in group B at 10-24h. In Group B, it was lower than Group C at 2-8h (p<0.05). Total morphine consumption was lower in Group BD compared to other groups and lower in group B than in the controls (p<0.001). Patient satisfaction was higher in Group BD than in other groups and was higher in both study groups than in the controls (p<0.001). Nausea-vomiting scores, antiemetic requirement, or additional analgesic administration were not significant among groups (p>0.05). The addition of dexmedetomidine to bupivacaine on TAP block decreased postoperative pain scores and morphine consumption; it also increased patient satisfaction in patients undergoing lower abdominal surgery. Dexmedetomidine did not have any effect on nausea and vomiting score and antiemetic requirement. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.
Screening esophagus during routine ultrasound: medical and cost benefits.
Abd Elrazek, Abd Elrazek M A; Eid, Khaled A; El-Sherif, Abd Elhalim A; Abd El Al, Usama M; El-Sherbiny, Samir M; Bilasy, Shymaa E
2015-01-01
Cost-effectiveness analysis is an approach used to determine the value of a medical care option and refers to a method used to assess the costs and health benefits of an intervention. Upon the diagnosis of liver cirrhosis, the current guidelines recommend that all cirrhotic patients have to be screened for the presence of esophageal varices by endoscopy. In addition, patients with a positive family history of esophageal cancer are screened annually. These approaches place a heavy burden on endoscopy units, and repeated testing over time may have a detrimental effect on patient compliance. Following the recommendations of a recent study entitled 'Detection of risky esophageal varices using two dimensional ultrasound: when to perform endoscopy', the intra-abdominal portion of the esophagus of 1100 patients was divided into a hepatic group, which included 650 patients, and a nonhepatic group, which included 450 patients, who presented with manifestations of liver diseases and gastrointestinal symptoms, respectively, and were examined using standard two-dimensional ultrasound (US) to evaluate cost effectiveness, standard issues, and medical benefits using conventional US. The overall effectiveness analysis of 1100 patients yielded a 41% cost standard benefit calculated to be $114,760 in a 6-month study. Two-dimensional US can play an important role in screening for esophageal abnormalities, thus saving money and time. The esophagus should be screened during routine conventional abdominal US.
Prospects for telediagnosis using ultrasound.
Dewey, C F; Thomas, J D; Kunt, M; Hunter, I W
1996-01-01
Ultrasound imaging is currently used as a primary diagnostic tool in cardiology, abdominal disorders, pulmonary medicine, trauma, and obstetrics. Because of its relatively low capital and operating costs as well as its growth potential, it represents one of the major diagnostic modalities of future health care. However, the use of ultrasonography as a mobile and powerful modality is controlled by the availability of a highly skilled technician to acquire the images and an experienced physician to interpret them. This paper discusses the technology required to increase the availability of a diagnosing physician by employing telerobotics. With this technology, the physician can guide the motion of the transducer by the technician from a remote location. Thus, the physician controls the examination and renders the diagnosis. It is shown that communication lines at 1.5 Mbits/s (T-1 speed) can, with appropriate compression, support both real-time viewing of the ultrasound images and telerobotic manipulation of the transducer. The incremental costs of telediagnosis for an examination are estimated to be a small fraction of the base charges and significantly less than the expense of bringing a physician to a remote location or transporting a patient to a regional medical center. Telediagnosis can, in addition, provide benefits from immediate interpretation and consultation that cannot be duplicated using store-and-forward scenarios.
Ultrasound Dopplerography of abdomen pathology using statistical computer programs
NASA Astrophysics Data System (ADS)
Dmitrieva, Irina V.; Arakelian, Sergei M.; Wapota, Alberto R. W.
1998-04-01
The modern ultrasound dopplerography give us the big possibilities in investigation of gemodynamical changes in all stages of abdomen pathology. Many of researches devoted to using of noninvasive methods in practical medicine. Now ultrasound Dopplerography is one of the basic one. We investigated 250 patients from 30 to 77 ages, including 149 men and 101 women. The basic diagnosis of all patients was the Ischaemic Pancreatitis. The Second diagnoses of pathology were the Ischaemic Disease of Heart, Gypertension, Atherosclerosis, Diabet, Vascular Disease of Extremities. We researched the abdominal aorta and her branches: Arteria Mesenterica Superior (AMS), truncus coeliacus (TC), arteria hepatica communis (AHC), arteria lienalis (AL). For investigation we use the following equipment: ACUSON 128 XP/10c, BIOMEDIC, GENERAL ELECTRIC (USA, Japan). We analyzed the following componetns of gemodynamical changes of abdominal vessels: index of pulsation, index of resistance, ratio of systol-dystol, speed of blood circulation. Statistical program included the following one: 'basic statistic's,' 'analytic program.' In conclusion we determined that the all gemodynamical components of abdominal vessels had considerable changes in abdominal ischaemia than in normal situation. Using the computer's program for definition degree of gemodynamical changes, we can recommend the individual plan of diagnostical and treatment program.
Ultrasound assessment of spleen size in collegiate athletes.
Hosey, R G; Mattacola, C G; Kriss, V; Armsey, T; Quarles, J D; Jagger, J
2006-03-01
To determine normal spleen dimensions in a healthy collegiate athletic population. 631 Division I collegiate athletes from one university participated in the study. During pre-participation examinations, demographic data collected were collected from volunteer athletes including sex, race, measurement of height and weight, and age. Subjects also completed a medical history form to determine any history of mononucleosis infection, platelet disorder, sickle cell disease (or trait), thalassaemia, or recent viral symptoms. Subjects then underwent a limited abdominal ultrasound examination, where splenic length and width were recorded. Mean (SD) splenic length was 10.65 (1.55) cm and width, 5.16 (1.21) cm. Men had larger spleens than women (p<0.001). White subjects had larger spleens than African-American subjects (p<0.001). A previous history of infectious mononucleosis or the presence of recent cold symptoms had no significant affect on spleen size. In more than 7% of athletes, baseline spleen size met current criteria for splenomegaly. There is a wide range of normal spleen size among collegiate athletes. Average spleen size was larger in men and white athletes than in women and black athletes. A single ultrasound examination for determination of splenomegaly is of limited value in this population.
Portable ultrasonography in mass casualty incidents: The CAVEAT examination.
Stawicki, Stanislaw Peter; Howard, James M; Pryor, John P; Bahner, David P; Whitmill, Melissa L; Dean, Anthony J
2010-11-18
Ultrasonography used by practicing clinicians has been shown to be of utility in the evaluation of time-sensitive and critical illnesses in a range of environments, including pre-hospital triage, emergency department, and critical care settings. The increasing availability of light-weight, robust, user-friendly, and low-cost portable ultrasound equipment is particularly suited for use in the physically and temporally challenging environment of a multiple casualty incident (MCI). Currently established ultrasound applications used to identify potentially lethal thoracic or abdominal conditions offer a base upon which rapid, focused protocols using hand-carried emergency ultrasonography could be developed. Following a detailed review of the current use of portable ultrasonography in military and civilian MCI settings, we propose a protocol for sonographic evaluation of the chest, abdomen, vena cava, and extremities for acute triage. The protocol is two-tiered, based on the urgency and technical difficulty of the sonographic examination. In addition to utilization of well-established bedside abdominal and thoracic sonography applications, this protocol incorporates extremity assessment for long-bone fractures. Studies of the proposed protocol will need to be conducted to determine its utility in simulated and actual MCI settings.
Perforator-Guided Drug Injection in the Treatment of Abdominal Wall Pain.
Weum, Sven; de Weerd, Louis
2016-07-01
Pain from the abdominal wall can be caused by nerve entrapment, a condition called abdominal cutaneous nerve entrapment syndrome (ACNES). As an alternative to surgery, ACNES may be treated with injection of local anesthetics, corticosteroids, or botulinum toxin at the point of maximal pain. The point of maximal pain was marked on the abdominal skin. Using color Doppler ultrasound, the corresponding exit point of perforating blood vessels through the anterior fascia of the rectus abdominis muscle was identified. Ultrasound-guided injection of botulinum toxin in close proximity to the perforator's exit point was performed below and above the muscle fascia. The technique was used from 2008 to 2014 on 15 patients in 46 sessions with a total of 128 injections without complications. The injection technique provided safe and accurate administration of the drug in proximity to the affected cutaneous nerves. The effect of botulinum toxin on ACNES is beyond the scope of this article. Perforator-guided injection enables precise drug administration at the location of nerve entrapment in ACNES in contrast to blind injections. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
[Differential diagnosis of abdominal pain].
Frei, Pascal
2015-09-02
Despite the frequency of functional abdominal pain, potentially dangerous causes of abdominal pain need to be excluded. Medical history and clinical examination must focus on red flags and signs for imflammatory or malignant diseases. See the patient twice in the case of severe and acute abdominal pain if lab parameters or radiological examinations are normal. Avoid repeated and useless X-ray exposure whenever possible. In the case of subacute or chronic abdominal pain, lab tests such as fecal calprotectin, helicobacter stool antigen and serological tests for celiac disease are very useful. Elderly patients may show atypical or missing clinical signs. Take care of red herrings and be skeptical whether your initial diagnosis is really correct. Abdominal pain can frequently be an abdominal wall pain.
Wen, Chuan-Bing; Li, Yong-Zhong; Tang, Qin-Qin; Sun, Lin; Xiao, Hong; Yang, Bang-Xiang; Song, Li; Liu, Hui
2013-03-01
To investigate the feasibility, accuracy of B ultrasound in the examination of joint space of lumbar spine facet joints compared with CT scan. Ten healthy adult volunteers were enrolled. The joint space of lumbar facet joints was measured by ultrasound. To identify the spinal levels, the posterior parasagittal sonograms were obtained at levels L1 to S1. The lumbar facet joints were delineated with the help of transverse sonograms at each level. Meanwhile, the lumbar facet joints were evaluated by spiral CT on the same plane, reformatted to 1-mm axial slices. A total of 88 lumbar facet joints from L1 to S1 were clearly visualized in the 10 volunteers. Both ultrasound and CT measurements showed the same average depth and lateral distance of lumbar facet joint space (P > 0.05). The lumbar facet joint space can be accurately demonstrated by ultrasound.
Epstein, E; Van Calster, B; Timmerman, D; Nikman, S
2016-01-01
To compare subjective ultrasound assessment and the ADNEX model with ultrasound-guided tru-cut biopsy to differentiate disseminated primary ovarian cancer from metastatic non-ovarian cancer. This was a prospective study including 143 consecutive women with disseminated malignancy of unknown primary origin, with a pelvic tumor/carcinosis. Women underwent either transvaginal or transrectal ultrasound as well as transabdominal ultrasound examination followed by tru-cut biopsy. The ultrasound examiner assessed tumor morphology, spread in the pelvis and abdomen, and predicted tumor origin as primary ovarian or metastatic using both subjective assessment and the ADNEX model. Histology from tru-cut biopsy served as the gold standard for assessment of diagnostic accuracy. Biopsy adequacy and the complication rate were assessed. Tru-cut biopsy was performed transvaginally in 131/143 (92%) women. Two women needed inpatient care (one had abdominal wall hematoma, and one infection). Biopsy resulted in a conclusive diagnosis in 126/143 (88%) women, amongst whom cytoreductive surgery was performed in 30/126 confirming the diagnosis in all cases. Non-ovarian metastatic cancer was found in 37/126 (29%) women and primary ovarian cancer in 89/126 (71%) women. Subjective ultrasound evaluation had a sensitivity of 82% (73/89) and a specificity of 70% (26/37) in predicting primary ovarian cancer. The ADNEX model had an area under the receiver-operating characteristics curve of 0.891 (95% CI, 0.794-0.946) (in women with an ovarian lesion, n = 104). Tumor origin was associated with age, CA 125, previous neoplasia, presence of omental cake and tumor mobility. Subjective ultrasound assessment and the ADNEX model can both be used to predict whether a pelvic tumor is metastatic and of non-ovarian origin, indicating the need for tru-cut biopsy, which is associated with very few complications and will provide a conclusive diagnosis in nine out of 10 women. Copyright © 2015 ISUOG
Ogedegbe, Chinwe; Morchel, Herman; Hazelwood, Vikki; Chaplin, William F; Feldman, Joseph
2012-12-18
Despite the use of e-FAST in management of patients with abdominal trauma, its utility in prehospital setting is not widely adopted. The goal of this study is to develop a novel portable telesonography (TS) system and evaluate the comparability of the quality of images obtained via this system among healthy volunteers who undergo e-FAST abdominal examination in a moving ambulance and at the ED. We hypothesize that: (1) real-time ultrasound images of acute trauma patients in the pre-hospital setting can be obtained and transmitted to the ED via the novel TS system; and (2) Ultrasound images transmitted to the hospital from the real-time TS system will be comparable in quality to those obtained in the ED. Study participants are three healthy volunteers (one each with normal, overweight and obese BMI category). The ultrasound images will be obtained by two ultrasound-trained physicians The TS is a portable sonogram (by Sonosite) interfaced with a portable broadcast unit (by Live-U). Two UTPs will conduct e-FAST examinations on healthy volunteers in moving ambulances and transmit the images via cellular network to the hospital server, where they are stored. Upon arrival in the ED, the same UTPs will obtain another set of images from the volunteers, which are then compared to those obtained in the moving ambulances by another set of blinded UTPs (evaluators) using a validated image quality scale, the Questionnaire for User Interaction Satisfaction (QUIS). Findings from this study will provide needed data on the validity of the novel TS in transmitting live images from moving ambulances to images obtained in the ED thus providing opportunity to facilitate medical care of a patient located in a remote or austere setting.
Imaging in gynecological disease (9): clinical and ultrasound characteristics of tubal cancer.
Ludovisi, M; De Blasis, I; Virgilio, B; Fischerova, D; Franchi, D; Pascual, M A; Savelli, L; Epstein, E; Van Holsbeke, C; Guerriero, S; Czekierdowski, A; Zannoni, G; Scambia, G; Jurkovic, D; Rossi, A; Timmerman, D; Valentin, L; Testa, A C
2014-03-01
To describe clinical history and ultrasound findings in patients with tubal carcinoma. Patients with a histological diagnosis of tubal cancer who had undergone preoperative ultrasound examination were identified from the databases of 13 ultrasound centers. The tumors were described by the principal investigator at each contributing center on the basis of ultrasound images, ultrasound reports and research protocols (when applicable) using the terms and definitions of the International Ovarian Tumor Analysis (IOTA) group. In addition, three authors reviewed together all available digital ultrasound images and described them using subjective evaluation of gray-scale and color Doppler ultrasound findings. We identified 79 women with a histological diagnosis of primary tubal cancer, 70 of whom (89%) had serous carcinomas and 46 (58%) of whom presented at FIGO stage III. Forty-nine (62%) women were asymptomatic (incidental finding), whilst the remaining 30 complained of abdominal bloating or pain. Fifty-three (67%) tumors were described as solid at ultrasound examination, 14 (18%) as multilocular solid, 10 (13%) as unilocular solid and two (3%) as unilocular. No tumor was described as a multilocular mass. Most tumors (70/79, 89%) were moderately or very well vascularized on color or power Doppler ultrasound. Normal ovarian tissue was identified adjacent to the tumor in 51% (39/77) of cases. Three types of ultrasound appearance were identified as being typical of tubal carcinoma using pattern recognition: a sausage-shaped cystic structure with solid tissue protruding into it like a papillary projection (11/62, 18%); a sausage-shaped cystic structure with a large solid component filling part of the cyst cavity (13/62, 21%); an ovoid or oblong completely solid mass (36/62, 58%). A well vascularized ovoid or sausage-shaped structure, either completely solid or with large solid component(s) in the pelvis, should raise the suspicion of tubal cancer, especially if normal
Haragan, Adriane F.; Hulsey, Thomas C.; Hawk, Angela F.; Newman, Roger B.; Chang, Eugene Y.
2015-01-01
OBJECTIVE We sought to compare fundal height and handheld ultrasound–measured fetal abdominal circumference (HHAC) for the prediction of fetal growth restriction (FGR) or large for gestational age. STUDY DESIGN This was a diagnostic accuracy study in nonanomalous singleton pregnancies between 24 and 40 weeks’ gestation. Patients underwent HHAC and fundal height measurement prior to formal growth ultrasound. FGR was defined as estimated fetal weight less than 10%, whereas large for gestational age was defined as estimated fetal weight greater than 90%. Sensitivity and specificity were calculated and compared using methods described elsewhere. RESULTS There were 251 patients included in this study. HHAC had superior sensitivity and specificity for the detection of FGR (sensitivity, 100% vs 42.86%) and (specificity, 92.62% vs 85.24%). HHAC had higher specificity but lower sensitivity when screening for LGA (specificity, 85.66% vs 66.39%) and (sensitivity, 57.14% vs 71.43%). CONCLUSION HHAC could prove to be a valuable screening tool in the detection of FGR. Further studies are needed in a larger population. PMID:25818672
Abdominal Aortic Aneurysm: Evolving Controversies and Uncertainties.
Carino, Davide; Sarac, Timur P; Ziganshin, Bulat A; Elefteriades, John A
2018-06-01
Abdominal aortic aneurysm (AAA) is defined as a permanent dilatation of the abdominal aorta that exceeds 3 cm. Most AAAs arise in the portion of abdominal aorta distal to the renal arteries and are defined as infrarenal. Most AAAs are totally asymptomatic until catastrophic rupture. The strongest predictor of AAA rupture is the diameter. Surgery is indicated to prevent rupture when the risk of rupture exceeds the risk of surgery. In this review, we aim to analyze this disease comprehensively, starting from an epidemiological perspective, exploring etiology and pathophysiology, and concluding with surgical controversies. We will pursue these goals by addressing eight specific questions regarding AAA: (1) Is the incidence of AAA increasing? (2) Are ultrasound screening programs for AAA effective? (3) What causes AAA: Genes versus environment? (4) Animal models: Are they really relevant? (5) What pathophysiology leads to AAA? (6) Indications for AAA surgery: Are surgeons over-eager to operate? (7) Elective AAA repair: Open or endovascular? (8) Emergency AAA repair: Open or endovascular?
Shamsi, MohammadBagher; Sarrafzadeh, Javad; Jamshidi, Aliashraf; Zarabi, Vida; Pourahmadi, Mohammad Reza
2016-05-01
There is a controversy regarding whether core stability exercise (CSE) is more effective than general exercise (GE) for chronic LBP. To compare different exercises regarding their effect on improving back strength and stability, performance of abdominal muscles is a useful index. Ultrasound imaging for measuring muscle thickness could be used to assess muscle performance. The aim of this study was to compare CSE and GE in chronic LBP using ultrasound imaging for measurement of thickness of the deep stabilizing and main global trunk muscles in non-specific chronic LBP. Each program included 16 training sessions three times a week. Using ultrasound imaging, four transabdominal muscle thickness were measured before and after the intervention. Disability and pain were measured as secondary outcomes. After the intervention on participants (n = 43), a significant increase in muscle thickness (hypertrophy) was seen only in right and left rectus abdominis in the GE group, but significant difference to the CSE group was only on the right side. Disability and pain reduced within the groups without a significant difference in the change between them. The present results provided evidence that only GE increased right and left rectus muscle thickness. The only significant difference between CSE and GE groups was the right rectus thickness. As rectus is a global muscle, the effect of GE on strength improvement (one side stronger than the other) may have a negative effect on motor control of lumbopelvic muscles and possibly increase the risk of back pain occurring or becoming worse, though this was not observed in the present study.
Angtuaco, Teresita L; Hopkins, Robert H; DuBose, Terry J; Bursac, Zoran; Angtuaco, Michael J; Ferris, Ernest J
2007-06-01
This project was designed to test the feasibility of introducing ultrasound to senior medical students as a primary diagnostic tool in the evaluation of patients. Specifically, its aim was to determine if it is possible for medical students untrained in sonography to gain basic competence in performing abdominal ultrasound with limited didactic and hands-on instructions. Registered sonographers provided the students with hands-on instructions on the use of a compact ultrasound system. They were likewise shown how to evaluate specific organs and perform measurements. The results of the student measurements and those obtained by the sonographers were compared. There was close correlation between the results obtained by sonographers and students on both normal and abnormal findings. This supports the concept that medical students can be taught basic ultrasound skills with limited didactic and hands-on instructions with the potential of using these skills in the patient clinics as an adjunct to routine physical diagnosis.
[Gallbladder contractility in children with functional abdominal pain or irritable bowel syndrome].
Iwańczak, Franciszek; Siedlecka-Dawidko, Jolanta; Iwanczak, Barbara
2013-07-01
III Rome Criteria of functional gastrointestinal disorders in children, distinguished the disturbances with abdominal pain, to which irritable bowel syndrome, functional abdominal pains, functional dyspepsia and abdominal migraine were included. THE AIM OF THE STUDY was sonographic assessment of the gallbladder and its contractility in functional abdominal pain and irritable bowel syndrome in children. The study comprised 96 children aged 6 to 18 years, 59 girls and 37 boys. Depending on diagnosis, the children were divided into three groups. 38 children with functional abdominal pain constituted the first group, 26 children with irritable bowel syndrome were included to the second group, the third group consisted of 32 healthy children (control group). Diagnosis of functional abdominal pain and irritable bowel syndrome was made based on the III Rome Criteria. In irritable bowel syndrome both forms with diarrhea (13) and with constipation (13) were observed. Anatomy and contractility of the gallbladder were assessed by ultrasound examination. The presence of septum, wall thickness, thick bile, vesicle volume in fasting state and 30th and 60th minute after test meal were taken into consideration. Test meal comprised about 15% of caloric requirement of moderate metabolism. Children with bile stones and organic diseases were excluded from the study. Thickened vesicle wall and thick bile were present more frequently in children with irritable bowel syndrome and functional abdominal pain than in control group (p < 0.02). Fasting vesicle volume was significantly greater in children with functional abdominal pain than in irritable bowel syndrome and control group (p = 0.003, p = 0.05). Vesicle contractility after test meal was greatest in children with functional abdominal pain. Evaluation of diminished (smaller than 30%) and enlarged (greater then 80%) gallbladder contractility at 30th and 60th minute after test meal demonstrated disturbances of contractility in children
Ultrasound Assessment of the Transverse Abdominis During Functional Movement.
Mangum, L Colby; Henderson, Kaitlin; Murray, Kyle P; Saliba, Susan A
2018-05-01
The traditional activation ratio divides contracted muscle thickness by resting muscle thickness while an abdominal draw-in maneuver is performed during hook lying. Ultrasound imaging during function, such as standing or gait, or peak knee flexion in a single-leg squat allows for further visualization of muscle activity. The goal of this study was to examine activation ratio calculations for transverse abdominis function in supine versus loaded conditions to determine the most informative normalization strategy for muscle activity based on thickness values. Transverse abdominis thickness was measured via ultrasound in 35 healthy participants under 4 different conditions. Comparisons were made between the traditional activation ratio tabletop, standing activation ratio (standing abdominal draw-in maneuver thickness/quiet standing thickness), and functional activation ratio (single-leg squat thickness/quiet standing thickness). Additionally, a cued activation ratio (single-leg squat with cued abdominal draw-in maneuver thickness/single-leg squat thickness) during the single-leg squat was obtained. Activation ratios of greater than 1.0 indicated that participants could activate the muscle during activity, and values were compared by analysis of variance. The participants included 23 women and 12 men with a mean age ± SD of 21.3 ± 2.7 years, mass of 66.1 ± 14.4 kg, and height of 168.5 ± 10.1 cm. Activation ratios exceeded 1.0 in 94.3% for the traditional activation ratio, 85.7% for the standing activation ratio, 82.9% for the cued activation ratio, and 82.9% for the functional activation ratio. With groups defined as tabletop activated or not, the standing, cued, and functional activation ratios were all significantly different (all P < .05). Normalizing muscle thickness to the corresponding functional position quiet value provides a useful functional activation ratio and may help clinicians better understand the transverse abdominis role
Abdominal Cystic Echinococcosis Treated with Albendazole. A Pediatric Cohort Study.
Moroni, Samanta; Moscatelli, Guillermo; Bournissen, Facundo García; González, Nicolás; Ballering, Griselda; Freilij, Héctor; Salgueiro, Fabián; Altcheh, Jaime
2016-01-01
Cystic echinococcosis is endemic in Argentina. The standard pharmacological treatment for the disease is albendazole, but surgery is a common alternative. Even though primary infection occurs mainly in the pediatric population, the optimal therapeutic option in pediatrics is not clearly defined and few pediatric cohorts with cystic echinococcosis treated with albendazole have been described to date. To describe therapeutic response to albendazole in a cohort of pediatric patients with abdominal cystic echinococcosis. Patients (0-18 years old) with abdominal cystic echinococcosis who were treated with albendazole between January 1998 and August 2013. Diagnosis of abdominal cystic echinococcosis was made by ultrasound. All patients received albendazole, 10-15 mg/kg/day. Epidemiological data, symptoms, number, location and outcome of the cysts, serology and treatment received were analyzed. The parameter used to assess treatment response was cyst changes evaluated by ultrasound follow up using the WHO-IWGE classification. A total of 28 patients (with 46 abdominal cysts) were included in the cohort. Mean age at enrolment was 9.4 years and mean duration of follow-up, 23.8 months. All patients resided in rural areas and had had contact with dogs. The asymptomatic form of the disease was the most common presentation. All patients received albendazole (mean duration: 142.5 days), with low incidence of adverse events. Albendazole had a positive effect on most of the cysts. Surgery was performed in 13 patients. Treatment with albendazole for uncomplicated cystic echinococcosis cysts is safe and effective, and can potentially reduce the need for surgical intervention.
Holmes, James F; Kelley, Kenneth M; Wootton-Gorges, Sandra L; Utter, Garth H; Abramson, Lisa P; Rose, John S; Tancredi, Daniel J; Kuppermann, Nathan
2017-06-13
The utility of the focused assessment with sonography for trauma (FAST) examination in children is unknown. To determine if the FAST examination during initial evaluation of injured children improves clinical care. A randomized clinical trial (April 2012-May 2015) that involved 975 hemodynamically stable children and adolescents younger than 18 years treated for blunt torso trauma at the University of California, Davis Medical Center, a level I trauma center. Patients were randomly assigned to a standard trauma evaluation with the FAST examination by the treating ED physician or a standard trauma evaluation alone. Coprimary outcomes were rate of abdominal computed tomographic (CT) scans in the ED, missed intra-abdominal injuries, ED length of stay, and hospital charges. Among the 925 patients who were randomized (mean [SD] age, 9.7 [5.3] years; 575 males [62%]), all completed the study. A total of 50 patients (5.4%, 95% CI, 4.0% to 7.1%) were diagnosed with intra-abdominal injuries, including 40 (80%; 95% CI, 66% to 90%) who had intraperitoneal fluid found on an abdominal CT scan, and 9 patients (0.97%; 95% CI, 0.44% to 1.8%) underwent laparotomy. The proportion of patients with abdominal CT scans was 241 of 460 (52.4%) in the FAST group and 254 of 465 (54.6%) in the standard care-only group (difference, -2.2%; 95% CI, -8.7% to 4.2%). One case of missed intra-abdominal injury occurred in a patient in the FAST group and none in the control group (difference, 0.2%; 95% CI, -0.6% to 1.2%). The mean ED length of stay was 6.03 hours in the FAST group and 6.07 hours in the standard care-only group (difference, -0.04 hours; 95% CI, -0.47 to 0.40 hours). Median hospital charges were $46 415 in the FAST group and $47 759 in the standard care-only group (difference, -$1180; 95% CI, -$6651 to $4291). Among hemodynamically stable children treated in an ED following blunt torso trauma, the use of FAST compared with standard care only did not improve clinical care, including
Utility of intravascular ultrasound examination during carotid stenting.
Joan, M Mellado; Moya, B Gómez; Agustí, F Pañella; Vidal, R García; Arjona, Y Abril; Alija, M P Fariñas; Paredero, V Martín
2009-01-01
Intravascular ultrasound (IVUS) examination may provide useful information during endovascular procedures. However, its actual clinical utility for carotid stenting remains unclear. We evaluated the usefulness of IVUS as a complementary tool during endovascular procedures in the carotid arteries and its impact on the modification of the therapeutic strategy. Between April 2006 and April 2007, 18 symptomatic patients (nine with transient ischemic attack, nine with stroke) underwent angioplasty and stenting of >70% stenosis of the internal carotid artery (ICA). Target lesions were identified with preoperative duplex scanning and further confirmed at angiography. Intraoperative IVUS examination was performed in all patients. Multilevel measurement of the artery as well as virtual histology images, before and after stenting, were obtained. The technique was 100% successful. There were no complications at the femoral puncture site and no neurological or other events. Compared with angiography, IVUS findings showed an average arterial diameter that was greater than 1.64+/-0.22mm. Based on virtual histology information, endovascular treatment was excluded in two patients and carotid endarterectomy was performed. Type or size of the stent was modified after IVUS examination in eight cases. IVUS examination provides complementary information to that obtained using conventional diagnostic procedures. It may be useful for characterizing the composition and measurement of the target lesion, choosing the type and size of the stent, and evaluating the results after the procedure.
NASA Astrophysics Data System (ADS)
Gur, David; Harnist, Kimberly; Gizienski, Terri-Ann; Zuley, Margarita; Hakim, Christiane; Lu, Amy; Sumkin, Jules; Abrams, Gordon; Ganott, Marie A.; Kelly, Amy E.; Tyma, Cathy S.; Chang, Thomas; BÓ§hm-Vélez, Marcella; Sobolewski, Robin
2018-03-01
Interpretations of breast ultrasound screening examinations result in high recall rates and large inter-radiologist variability, frequently leading to "conservative" recommendations. Double reading of all breast ultrasound screening examinations is cost prohibitive, but double reading of only "initially recalled" cases may prove efficacious. We assessed changes in recommendations, if any, by providing a consensus second opinion in a limited subset of examinations initially recommended for recall. We performed a retrospective reader study with 197 ultrasound examinations (97 not recalled and 100 recalled clinically). First, we generated a consensus "second opinion" consisting of the majority vote of three independent readings of each case by experienced ultrasound interpreters. During the reader study that followed, if the reader recommended a "recall" and the "consensus second opinion" did not, a message to that effect was displayed and the reader was asked to re-review the exam and re-assess if, knowing the second opinion, a re-rating of the case was warranted. We compared performance levels pre- and post- the second opinion. The second opinion resulted in "no recall" recommendations of 141 cases in the entire set, including four cancer cases missed by all three readers. On average, radiologists received "warning" messages in 30 cases (range 15-50), or in 15% of cases. Rating changes (downgrades to no recall) occurred in 36 of these cases. These changes resulted in a possible recall rate reduction of 28% in prompted cases or 14% overall recall reduction, while increasing the false negative rate by only one case missed by 2 readers ( 1%).
NASA Astrophysics Data System (ADS)
Di Lascio, N.; Kusmic, C.; Stea, F.; Faita, F.
2017-03-01
Wave Intensity Analysis (WIA) can provide parameters representative of the interaction between the vascular network and the heart. It has been already demonstrated that WIA-derived biomarkes have a quantitative physiological meaning. Aim of this study was to develop an image process algorithm for performing non-invasive WIA in mice and correlate commonly used cardiac function parameters with WIA-derived indexes. Sixteen wild-type male mice (8 weeks-old) were imaged with high-resolution ultrasound (Vevo 2100). Abdominal aorta and common carotid pulse wave velocities (PWVabd, PWVcar) were obtained processing B-Mode and PW-Doppler images and employed to assess WIA. Amplitudes of the first (W1abd, W1car) and the second (W2abd, W2car) local maxima and minimum (Wbabd,Wbcar) were evaluated; areas under the negative part of the curve were also calculated (NAabd, NAcar). Cardiac output (CO), ejection fraction (EF) fractional shortening (FS) and stroke volume (SV) were estimated; strain analysis provided strain and strain rate values for longitudinal, radial and circumferential directions (LS, LSR, RS, RSR, CS, CSR). Isovolumetric relaxation time (IVRT) was calculated from mitral inflow PW-Doppler images; IVRT values were normalized for cardiac cycle length. W1abd was correlated with LS (R=0.65) and LSR (R=0.59), while W1car was correlated with CO (R=0.58), EF (R=0.72), LS (R=0.65), LSR (R=0.89), CS (R=0.71), CSR (R=0.70). Both W2abd and W2car were not correlated with IVRT. Carotid artery WIA-derived parameters are more representative of cardiac function than those obtained from the abdominal aorta. The described US-based method can provide information about cardiac function and cardio-vascular interaction simply studying a single vascular site.
Matar, M; Picone, O; Dalmon, C; Ayoubi, J-M
2013-09-01
To evaluate the sonographers' knowledge of the National Technical Committee of Ultrasound's recommendations concerning second trimester ultrasound. Anonymous questionnaire was sent by e-mails containing 25 questions about demographic elements, the practice of second trimester ultrasound and the recommendations of the National Technical Committee of Ultrasound about second trimester ultrasound. Six hundred and eighty-four responses were obtained. Six hundred and fifty-three upon 684 (95%) of respondents practice second trimester ultrasound and 635 upon 653 (97%) know about the existence of the report of the National Technical Committee of Ultrasound. The rates of correct answers concerning recommended biometrical images vary between 97% for the biparietal diameter and head circumference, 98% for abdominal circumference and 100% for the femur length. While for morphological images, rates vary between 52% and 100%. A subgroup analysis (whether the respondents have already read the recommendations or not) showed that those who had read the recommendations have significantly better results than those who did not. Those who have already read the recommendations have better knowledge and global knowledge can be improved. National recommendations serve to promote a policy of quality assurance of ultrasound and may be used in medicolegal issues. The societies that make recommendations should more diffuse their work and practitioners should make effort to pursue the continuing medical education and to implement the recommendations. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Nerve ultrasound reliability of upper limbs: Effects of examiner training.
Garcia-Santibanez, Rocio; Dietz, Alexander R; Bucelli, Robert C; Zaidman, Craig M
2018-02-01
Duration of training to reliably measure nerve cross-sectional area with ultrasound is unknown. A retrospective review was performed of ultrasound data, acquired and recorded by 2 examiners-an expert and either a trainee with 2 months (novice) or a trainee with 12 months (experienced) of experience. Data on median, ulnar, and radial nerves were reviewed for 42 patients. Interrater reliability was good and varied most with nerve site but little with experience. Coefficient of variation (CoV) range was 9.33%-22.5%. Intraclass correlation coefficient (ICC) was good to excellent (0.65-95) except ulnar nerve-wrist/forearm and radial nerve-humerus (ICC = 0.39-0.59). Interrater differences did not vary with nerve size or body mass index. Expert-novice and expert-experienced interrater differences and CoV were similar. The ulnar nerve-wrist expert-novice interrater difference decreased with time (r s = -0.68, P = 0.001). A trainee with at least 2 months of experience can reliably measure upper limb nerves. Reliability varies by nerve and location and slightly improves with time. Muscle Nerve 57: 189-192, 2018. © 2017 Wiley Periodicals, Inc.
Chen, Hong; Hou, Gary Y.; Han, Yang; Payen, Thomas; Palermo, Carmine F.; Olive, Kenneth P.; Konofagou, Elisa E.
2015-01-01
Harmonic motion imaging (HMI) is a radiation force-based elasticity imaging technique that tracks oscillatory tissue displacements induced by sinusoidal ultrasonic radiation force to assess relative tissue stiffness. The objective of this study was to evaluate the feasibility of HMI in pancreatic tumor detection and high-intensity focused ultrasound (HIFU) treatment monitoring. The HMI system consisted of a focused ultrasound transducer, which generated sinusoidal radiation force to induce oscillatory tissue motion at 50 Hz, and a diagnostic ultrasound transducer, which detected the axial tissue displacements based on acquired radiofrequency signals using a 1D cross-correlation algorithm. For pancreatic tumor detection, HMI images were generated for pancreatic tumors in transgenic mice and normal pancreases in wild-type mice. The obtained HMI images showed a high contrast between normal and malignant pancreases with an average peak-to-peak HMI displacement ratio of 3.2. Histological analysis showed that no tissue damage was associated with HMI when it was used for the sole purpose of elasticity imaging. For pancreatic tumor ablation monitoring, the focused ultrasound transducer was operated with a higher acoustic power and longer pulse length than that used in tumor detection to simultaneously induce HIFU thermal ablation and oscillatory tissue displacements, allowing HMI monitoring without interrupting tumor ablation. HMI monitoring of HIFU ablation found significant decreases in the peak-to-peak HMI displacements before and after HIFU ablation with a reduction rate ranging from 15.8% to 57.0%. The formation of thermal lesions after HIFU exposure was confirmed by histological analysis. This study demonstrated the feasibility of HMI in abdominal tumor detection and HIFU ablation monitoring. PMID:26415128
Iyer, Rajalakshmi; Nallasamy, Karthi
2018-01-01
Abdominal pain is one of the common symptoms reported by children in urgent care clinics. While most children tend to have self-limiting conditions, the treating pediatrician should watch out for underlying serious causes like intestinal obstruction and perforation peritonitis, which require immediate referral to an emergency department (ED). Abdominal pain may be secondary to surgical or non-surgical causes, and will differ as per the age of the child. The common etiologies for abdominal pain presenting to an urgent care clinic are acute gastro-enteritis, constipation and functional abdominal pain; however, a variety of extra-abdominal conditions may also present as abdominal pain. Meticulous history taking and physical examination are the best tools for diagnosis, while investigations have a limited role in treating benign etiologies.
Clinical versus ultrasound examination of the thyroid gland in common clinical practice.
Brander, A; Viikinkoski, P; Tuuhea, J; Voutilainen, L; Kivisaari, L
1992-01-01
In a prospective series of 72 patients, clinical and ultrasonographic examination of the thyroid gland were compared in detail. Normal-sized lobes were differentiated from enlarged ones both by inspection and by palpation. When lobar size was assessed by palpation, the estimate was most clearly influenced by increase in width. The correlation between two examiners in lobe size assessment was significant. In the classification of thyroid disease as diffuse, solitary, or multinodular, clinical examination and ultrasonography correlated significantly. However, only one third of the clinically solitary nodules proved to be solitary by ultrasound examination. Of 77 separate nodules, 43 escaped detection on clinical examination. Of these 43, 14 nodules exceeded 2 cm in diameter. It is concluded that the use of ultrasonography frequently alters the primary evaluation of thyroid nodularity based on palpation.
Abdominal Pain in Children: From the Eternal City to the Examination Room.
Zeiter, Donna K
2017-06-01
Abdominal pain is a common presenting symptom in children. The differential diagnosis of abdominal pain is extensive; however, a vast majority of patients ultimately are diagnosed with functional abdominal pain disorders. Functional gastrointestinal disorders are defined using the recently released Rome IV criteria. These are not diagnoses of exclusion. If there are no alarm signs, the diagnosis may be made with a focused evaluation. Treatment of these disorders requires a biopsychosocial approach to the disorder and an individualized and multipronged treatment plan. Copyright © 2017 Elsevier Inc. All rights reserved.
Hyde, Jodie; Stanton, Warren R; Hides, Julie A
2012-02-01
The aim of this study was to examine the automatic recruitment of the deep abdominal muscles during a unilateral simulated weight-bearing task by elite Australian Rules football (AFL) players with and without low back pain (LBP). An observational cross-sectional study was conducted using ultrasound imaging to measure the thickness of the internal oblique (IO) and transversus abdominis (TrA) muscles. Thirty-seven elite male AFL players participated. Repeated measures factors included 'force level' (rest, 25% and 45% of body weight), 'leg' (dominant or non-dominant kicking leg) and 'side' (ultrasound side ipsilateral or contralateral to the leg used for the weight-bearing task). The dependent variables were thickness of the IO and TrA muscles. The results of this study showed that thickness of the IO (p<.0001) and TrA (p<.0001) muscles increased in response to 'force level'. During the task, the thickness of the IO muscle on the contralateral side of the trunk relative to the leg being tested, increased more in participants with current LBP (p=.034). This pattern was more distinct on the non-dominant kicking leg. Altered abdominal muscle recruitment in elite athletes with low back pain may be an attempt by the central nervous system (CNS) to compensate for inadequate lumbo-pelvic stability. Copyright © 2011 Elsevier B.V. All rights reserved.
Intravascular application of electrocautery in a rabbit model of abdominal aortic endarterectomy
Wang, Chuan; Xin, Yi; Li, Na; Li, Diankun; Li, Jingxing; Gu, Chengxiong
2017-01-01
Effective therapies for preventing perioperative complications such as thrombosis and inflammation after coronary endarterectomy (CE) are lacking. Electrocoagulation electrotomes have been routinely used in surgery for their cutting, clotting, and hemostatic properties. As strong flattening tools, their electrocautery function may prevent mechanical intimal-adventitial injury to arterial circulation and attenuate stenosis. The present study investigated the effects of intravascular application of electrocautery on ameliorating inflammation and thrombosis in a rabbit model of abdominal aortic endarterectomy. New Zealand rabbits were randomly divided into the sham, control (endarterectomy), and study (endarterectomy + electrocautery) groups with 10 in each group. Abdominal aortas were partially blocked and intima was removed. Electrocautery was performed with an electrocoagulation electrotome through the entire blocked vessel lumen. Vascular ultrasound parameters, molecular biological and histological characteristics of the abdominal aorta including vascular diameter, blood flow velocity, serum interleukin-6 (IL-6) and tumor necrosis factor-α (TNF-α) levels, and apoptosis rate of vascular endothelial cells (ECs) were evaluated postoperatively by vascular Doppler ultrasound, ELISA, real-time RT-PCR, flow cytometry, and immunofluorescence at various time points. Compared with the endarterectomy + electrocautery group, the isolated endarterectomy group had significantly increased levels and gene expression of TNF-α and IL-6 (P<0.05), and rates of apoptosis of vascular ECs (P<0.05), with gradual vascular stenosis and decreased blood flow velocity. In conclusion, intravascular application of electrocautery has favorable short-term effects on the abdominal aorta and can reduce inflammation in a rabbit model of abdominal aorta endarterectomy. Long-term anti-inflammatory and anti-thrombotic effects on arterial remodeling and the clinical value of electrocautery in CE
Intravascular application of electrocautery in a rabbit model of abdominal aortic endarterectomy.
Wang, Chuan; Xin, Yi; Li, Na; Li, Diankun; Li, Jingxing; Gu, Chengxiong
2017-07-01
Effective therapies for preventing perioperative complications such as thrombosis and inflammation after coronary endarterectomy (CE) are lacking. Electrocoagulation electrotomes have been routinely used in surgery for their cutting, clotting, and hemostatic properties. As strong flattening tools, their electrocautery function may prevent mechanical intimal-adventitial injury to arterial circulation and attenuate stenosis. The present study investigated the effects of intravascular application of electrocautery on ameliorating inflammation and thrombosis in a rabbit model of abdominal aortic endarterectomy. New Zealand rabbits were randomly divided into the sham, control (endarterectomy), and study (endarterectomy + electrocautery) groups with 10 in each group. Abdominal aortas were partially blocked and intima was removed. Electrocautery was performed with an electrocoagulation electrotome through the entire blocked vessel lumen. Vascular ultrasound parameters, molecular biological and histological characteristics of the abdominal aorta including vascular diameter, blood flow velocity, serum interleukin-6 (IL-6) and tumor necrosis factor-α (TNF-α) levels, and apoptosis rate of vascular endothelial cells (ECs) were evaluated postoperatively by vascular Doppler ultrasound, ELISA, real-time RT-PCR, flow cytometry, and immunofluorescence at various time points. Compared with the endarterectomy + electrocautery group, the isolated endarterectomy group had significantly increased levels and gene expression of TNF-α and IL-6 (P<0.05), and rates of apoptosis of vascular ECs (P<0.05), with gradual vascular stenosis and decreased blood flow velocity. In conclusion, intravascular application of electrocautery has favorable short-term effects on the abdominal aorta and can reduce inflammation in a rabbit model of abdominal aorta endarterectomy. Long-term anti-inflammatory and anti-thrombotic effects on arterial remodeling and the clinical value of electrocautery in CE
Plain abdominal radiography in acute abdominal pain; past, present, and future
Gans, Sarah L; Stoker, Jaap; Boermeester, Marja A
2012-01-01
Several studies have demonstrated that a diagnosis based solely on a patient’s medical history, physical examination, and laboratory tests is not reliable enough, despite the fact that these aspects are essential parts of the workup of a patient presenting with acute abdominal pain. Traditionally, imaging workup starts with abdominal radiography. However, numerous studies have demonstrated low sensitivity and accuracy for plain abdominal radiography in the evaluation of acute abdominal pain as well as various specific diseases such as perforated viscus, bowel obstruction, ingested foreign body, and ureteral stones. Computed tomography, and in particular computed tomography after negative ultrasonography, provides a better workup than plain abdominal radiography alone. The benefits of computed tomography lie in decision-making for management, planning of a surgical strategy, and possibly even avoidance of negative laparotomies. Based on abundant available evidence, major advances in diagnostic imaging, and changes in the management of certain diseases, we can conclude that there is no place for plain abdominal radiography in the workup of adult patients with acute abdominal pain presenting in the emergency department in current practice. PMID:22807640
[Ultrasound in the emergency department as an extension of the practitioner's clinical examination].
Schmit, Aline; Pécoul, David; Lebret, Yannick; Dussoix, Philippe
2018-01-31
Ultrasound in the emergency department and general practice can be used as an extension of the physical examination, answering simple questions. It requires a short basic training that is easily accessible. This article illustrates with a few examples (kidney, lung and fractures) the interest of this formidable tool becoming unavoidable in the emergency department and general practice.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flores-M, E.; Gamboa de Buen, I.; Buenfil, A. E.
Computed Tomography (CT) is a high dose X ray imaging procedure and its use has rapidly increased in the last two decades fueled by the development of helical CT. The aim of this study is to present values of the dosimetric quantities for CT paediatric examinations of thoracic and abdominal regions. The protocols studied were those of chest, lung-mediastine, chest-abdomen, pulmonary high resolution and mediastine-abdomen, which are the more common examinations performed at ''Hospital Infantil de Mexico Federico Gomez'' in the thoracic-abdominal region. The measurements were performed on a Siemens SOMATOM Sensation 16 CT Scanner and the equipment used wasmore » a CT pencil ionization chamber, connected to an electrometer. This system was calibrated for RQT9 CT beam quality. A PMMA head phantom with diameter of 16 cm and length of 15 cm was also used. The dosimetric quantities measured were the weighted air kerma index (C{sub w}), the volumetric dose index (C{sub vol}) and the CT air kerma-length product. It was found that the pulmonary high resolution examination presented the highest values for the C{sub w}(31.1 mGy) and C{sub vol}(11.1 mGy). The examination with the lowest values of these two quantities was the chest-abdomen protocol with 10.5 mGy for C{sub w} and 5.5 mGy for C{sub vol}. However, this protocol presented the highest value for P{sub KL,CT}(282.2 mGy cm) when considering the average clinical length of the examinations.« less
Lins, Carolina Freitas; Lima de Sá Ribeiro, Daniel; Dourado Santos, Willer Gonçalves; Rosa, Genevievi; Machicado, Viviane; Pedreira, Ana Luisa; Pimenta da Fonseca, Emanuela; Mota Duque Sousa, Anna Paula; Rodrigues Silva, Carla Baleeiro; Matos, Marcos Antonio Almeida; Santiago, Mittermayer Barreto
2017-09-01
Diagnosis of synovitis/tenosynovitis by physical examination can be difficult. Ultrasound (US) can be an effective tool for the evaluation of joint involvement in systemic lupus erythematosus (SLE). This study will describe musculoskeletal findings by US in SLE patients and the evaluation of their correlation with physical examination. SLE patients underwent clinical/sonographic evaluation of hand/wrists. In total, 896 joints were evaluated: at least 1 change on physical examination was found in 136 joints and at least 1 US abnormality was found in 65 of 896 joints. Out of the 65 joints with US changes, only 13 had findings on physical examination. Conversely, 111 joints had tenderness on physical examination with no sonographic abnormalities. Tenosynovitis was statistically significant more frequently with joint edema (41%) (p = 0.0003). US can detect musculoskeletal changes in only a minority of symptomatic SLE patients. Clinical findings may be related to some reasons that cannot be explained using US. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Liotta, A; Billen, F; Heimann, M; Hamaide, A; Rizza, M; Etienne, A L; Bolen, G
2017-04-01
Lymph nodal cyst-like lesions are occasionally identified during abdominal ultrasound in dogs. However, a study evaluating their prevalence and clinical significance is lacking. The aim of this observational cross-sectional study was to evaluate prevalence, most common location and concurrent diseases of cyst-like lymph nodes detected during abdominal ultrasound. Affected lymph nodes, patient signalment and concurrent diseases of dogs with cyst-like lymph nodal lesions having undergone abdominal ultrasound over a one-year period were recorded. Twenty-three affected lymph nodes were observed in 17/553 dogs (prevalence=3 per cent). The most commonly affected was the lumbar lymphocenter (7/23), followed by the coeliac (6/23), the cranial mesenteric (5/23) and the iliosacral (5/23). Twenty-three concurrent diseases were diagnosed in 17 dogs, among which 16/23 were non-neoplastic (70 per cent). The most common concurrent disease was renal insufficiency (8/23), followed by neoplasia (7/23), gastroenteropathy (3/23), benign prostatic disease (2/23), pancreatitis (1/23), peritonitis (1/23) and neurological disease (1/23). No statistical correlation existed between cyst-like lymph nodal lesion and a specific neoplastic or non-neoplastic disease. In conclusion, in the present study, cyst-like lymph nodal lesions have a low prevalence, involve different lymphocenters and were found in dogs affected by different diseases, including both non-neoplastic and neoplastic aetiologies. British Veterinary Association.
Rupture of an Abdominal Aortic Aneurysm in a Young Man with Marfan Syndrome.
Pedersen, Maria Weinkouff; Huynh, Khiem Dinh; Baandrup, Ulrik Thorngren; Nielsen, Dorte Guldbrand; Andersen, Niels Holmark
2018-04-01
Abdominal aortic aneurysms (AAAs) are very rare in Marfan syndrome. We present a case with a young nonsmoking and normotensive male with Marfan syndrome, who developed an infrarenal AAA that presented with rupture to the retroperitoneal cavity causing life-threatening bleeding shock. The patient had acute aortic surgery and survived. Five months before this incident, the patient had uneventful elective aortic root replacement (ad modum David) due to an enlarged aortic root. At that time, his abdominal aorta was assessed with a routine ultrasound scan that showed a normal-sized abdominal aorta. This documents that the aneurysm had evolved very rapidly despite young age and absence of risk factors. Copyright © 2018 Elsevier Inc. All rights reserved.
Body Mass Normalization for Lateral Abdominal Muscle Thickness Measurements in Adolescent Athletes.
Linek, Pawel
2017-09-01
To determine the value of allometric parameters for ultrasound measurements of the oblique external (OE), oblique internal (OI), and transversus abdominis (TrA) muscles in adolescent athletes. The allometric parameter is the slope of the linear regression line between the log-transformed body mass and log-transformed muscle size measurement. The study included 114 male adolescent football players between the ages of 10 and 19 years. All individuals with no surgical procedures performed on the trunk area and who had played a sport for at least 2 years were included. A real-time B-mode ultrasound scanner with a linear array transducer was used to obtain images of the lateral abdominal muscles from both sides of the body. A stabilometric platform was used to assess the body mass value. The correlations between body mass and the OE, OI, and TrA muscle thicknesses were r = 0.73, r = 0.79, and r = 0.64, respectively (in all cases, P < .0001). The allometric parameters were 0.77 for the OE, 0.67 for the OI, and 0.61 for the TrA. Using these parameters, no significant correlations were found between body mass and the allometric-scaled thickness of the lateral abdominal muscles. Significant positive correlations exist between body mass and lateral abdominal muscle thickness in adolescent athletes. Therefore, it is reasonable to advise that the values of the allometric parameters for the OE, OI, and TrA muscles obtained in this study should be used, and the allometric-scaled thicknesses of those muscles should be analyzed in future research on adolescent athletes. © 2017 by the American Institute of Ultrasound in Medicine.
Abdominal Wall Endometriosis Eleven Years After Cesarean Section: Case Report
Djaković, Ivka; Vuković, Ante; Bolanča, Ivan; Soljačić Vraneš, Hrvojka; Kuna, Krunoslav
2017-03-01
Endometriosis is a common chronic disease characterized by growth of the endometrial gland and stroma outside the uterus. Symptoms affect physical, mental and social well-being. Extrapelvic location of endometriosis is very rare. Abdominal wall endometriosis occurs in 0.03%-2% of women with a previous cesarean section or other abdominopelvic operation. The leading symptoms are abdominal nodular mass, pain and cyclic symptomatology. The number of cesarean sections is increasing and so is the incidence of abdominal wall endometriosis as a potential complication of the procedure. There are cases of malignant transformation of abdominal wall endometriosis. Therefore, it is important to recognize this condition and treat it surgically. We report a case of a 37-year-old woman with abdominal wall endometriosis 11 years after cesarean section. She had low abdominal pain related to menstrual cycle, which intensified at the end of menstrual bleeding. A nodule painful to palpation was found in the medial part of previous Pfannenstiel incision. Ultrasound guided biopsy was performed and the diagnosis of endometriosis confirmed. Surgery is the treatment of choice for abdominal wall endometriosis. Excision with histologically proven free surgical margins of 1 cm is mandatory to prevent recurrence. A wide spectrum of mimicking conditions is the main reason for late diagnosis and treatment of abdominal wall endometriosis. In our case, the symptoms lasted for eight years and had intensified in the last six months prior to surgery.
Novel Use of Ultrasound to Teach Reproductive System Physical Examination Skills and Pelvic Anatomy.
Parikh, Tejal; Czuzak, Maria; Bui, Naomi; Wildner, Corinna; Koch, Bryna; Leko, Elizabeth; Rappaport, William; Adhikari, Srikar; Gordon, Paul; Gura, Mike; Ellis, Susan
2018-03-01
To determine whether integration of ultrasound (US) into a reproductive system examination clinical skills lab can increase confidence in palpating key reproductive structures during testicular and bimanual pelvic examinations, reduce anxiety about conducting testicular and bimanual pelvic examinations, and improve performance on multiple-choice questions based on structure identification using US images. Second-year medical students enrolled in the Life Cycle preclinical course participated in this cross-sectional study. A single learning activity was developed to pair the teaching of the reproductive system physical examination with the use of US in the clinical skills lab. The evaluation of the teaching session consisted of a pre-post analysis of student self-reported knowledge, confidence, and anxiety. The response rate for the pre survey was 82% (n = 96), and the rate for the post survey was 79% (n = 93). Students' confidence in their ability to identify reproductive system structures on US images increased from pre to post survey. Their confidence in their ability to palpate the epididymis, uterus, and ovary during a physical examination improved, and their anxiety about conducting testicular and bimanual pelvic examinations decreased. Student satisfaction with the session was high. Students' performance on multiple-choice questions based on structure identification using US images was at 96% or higher. Our study findings support the integration of US into a reproductive system examination clinical skills lab. Medical students acquire competency and confidence in reproductive system physical examination skills with US integration. © 2017 by the American Institute of Ultrasound in Medicine.
Torsion of normal adnexa in postmenarcheal women: can ultrasound indicate an ischemic process?
Smorgick, N; Maymon, R; Mendelovic, S; Herman, A; Pansky, M
2008-03-01
Torsion of normal adnexa is a rare event involving steadily increasing congestion and ischemia of the ovary. We investigated whether this process can be characterized by sonographic features. Twelve menstrually cycling women with 14 separate episodes of laparoscopic-proven torsion of normal adnexa were identified retrospectively, and the results of their preoperative gray-scale ultrasound examinations and Doppler flow evaluations were analyzed. The cases were classified into 'short-term' (< 24 h; range, 3-24 h) and 'prolonged' (> 24 h; range, 1-10 days) duration of torsion according to the reported period of abdominal pain before admission. Absence of any additional adnexal pathology was confirmed by both intraoperative inspection and postoperative follow-up ultrasound examinations. The median age of the cohort was 24.0 (interquartile range (IQR), 20.5-28.7) years, and parity ranged from 0 to 3. All affected ovaries were significantly enlarged compared with non-affected ones (median cross-sectional area, 18.1 (IQR, 12.4-26.4) cm(2) vs. 4.3 (IQR, 2.9-6.2) cm(2), P < 0.01). We could distinguish two distinct sonographic patterns of torted ovaries: there were numerous small peripheral follicles in the ovarian parenchyma in nine cases, and there was a solid-appearing mass with hypo- and hyperechogenic foci in five cases. Comparison of the ultrasound images of patients with short-term vs. long-term abdominal pain revealed that the solid-appearing ovary was more common in the latter group (0/6 vs. 5/8, P = 0.03), while there was no significant difference between groups in the presence of free pelvic fluid or median ovarian cross-sectional area. Intraovarian blood flow was diminished or absent in five of the eight patients in whom color Doppler imaging was performed. Ultrasound images of twisted normal adnexa may vary according to the duration of the condition, reflecting the pathological series of events of increased ovarian congestion and necrosis. Recognition of the
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muller, A., E-mail: arnaud.muller@chu-lyon.fr; Petrusca, L.; Auboiroux, V.
2013-12-15
Extracorporeal high-intensity focused ultrasound (HIFU) is a minimally invasive therapy considered with increased interest for the ablation of small tumors in deeply located organs while sparing surrounding critical tissues. A multitude of preclinical and clinical studies have showed the feasibility of the method; however, concurrently they showed several obstacles, among which the management of respiratory motion of abdominal organs is at the forefront. The aim of this review is to describe the different methods that have been proposed for managing respiratory motion and to identify their advantages and weaknesses. First, we specify the characteristics of respiratory motion for the liver,more » kidneys, and pancreas and the problems it causes during HIFU planning, treatment, and monitoring. Second, we make an inventory of the preclinical and clinical approaches used to overcome the problem of organ motion. Third, we analyze their respective benefits and drawbacks to identify the remaining physical, technological, and clinical challenges. We thereby consider the outlook of motion compensation techniques and those that would be the most suitable for clinical use, particularly under magnetic resonance thermometry monitoring.« less
A Newborn With Abdominal Pain.
Alwan, Riham; Drake, Meredith; Gurria Juarez, Juan; Emery, Kathleen H; Shaaban, Aimen F; Szabo, Sara; Sobolewski, Brad
2017-11-01
A previously healthy 3-week-old boy presented with 5 hours of marked fussiness, abdominal distention, and poor feeding. He was afebrile and well perfused. His examination was remarkable for localized abdominal tenderness and distention. He was referred to the emergency department in which an abdominal radiograph revealed gaseous distention of the bowel with a paucity of gas in the pelvis. Complete blood cell count and urinalysis were unremarkable. His ongoing fussiness and abnormal physical examination prompted consultation with surgery and radiology. Our combined efforts ultimately established an unexpected diagnosis. Copyright © 2017 by the American Academy of Pediatrics.
Sohn, Minsung; Cho, Kyung-Hwan; Han, Kyung-Do; Choi, Mankyu; Kim, Yang-Hyun
2017-01-01
We examined relationships between sitting time and obesity or abdominal obesity according to sex and socioeconomic status in elderly people. We analyzed data from the Korean National Health and Nutrition Examination Survey 2013, and 1565 participants were included in the study. Multivariate logistic regression analysis was used to examine relationships between sitting time and obesity or abdominal obesity according to sex and socioeconomic status. Sitting time was positively correlated with body mass index in men and women and waist circumference in men. When considering socioeconomic factors, men who sat for 5 hours or longer and fell within the lowest income were more likely to have obesity and abdominal obesity relative to men who sat for 5 hours or shorter and earned higher incomes (odds ratio [95% confidence interval] = 1.80 [1.14-2.84] and 1.63 [1.02-2.61] respectively), and women who sat for 5 hours or longer and fell within the lowest educational level were more likely to have obesity relative to women who sat for 5 hours or less and were educated to a higher level (1.24 [1.01-1.85]). Strategies to reduce sedentary behavior would help to prevent obesity in older men who earn low incomes and women with lower levels of educational attainment.
Smart Ultrasound Remote Guidance Experiment (SURGE) Preliminary Findings
NASA Technical Reports Server (NTRS)
Hurst, Victor; Dulchavsky, Scott; Garcia, Kathleen; Sargsyan, Ashot; Ebert, Doug
2009-01-01
To date, diagnostic quality ultrasound images were obtained aboard the International Space Station (ISS) using the ultrasound of the Human Research Facility (HRF) rack in the Laboratory module. Through the Advanced Diagnostic Ultrasound in Microgravity (ADUM) and the Braslet-M Occlusion Cuffs (BRASLET SDTO) studies, non-expert ultrasound operators aboard the ISS have performed cardiac, thoracic, abdominal, vascular, ocular, and musculoskeletal ultrasound assessments using remote guidance from ground-based ultrasound experts. With exploration class missions to the lunar and Martian surfaces on the horizon, crew medical officers will necessarily need to operate with greater autonomy given communication delays (round trip times of up to 5 seconds for the Moon and 90 minutes for Mars) and longer periods of communication blackouts (due to orbital constraints of communication assets). The SURGE project explored the feasibility and training requirements of having non-expert ultrasound operators perform autonomous ultrasound assessments in a simulated exploration mission outpost. The project aimed to identify experience, training, and human factors requirements for crew medical officers to perform autonomous ultrasonography. All of these aims pertained to the following risks from the NASA Bioastronautics Road Map: 1) Risk 18: Major Illness and Trauna; 2) Risk 20) Ambulatory Care; 3) Risk 22: Medical Informatics, Technologies, and Support Systems; and 4) Risk 23: Medical Skill Training and Maintenance.
Pateman, K; Holland, T K; Knez, J; Derdelis, G; Cutner, A; Saridogan, E; Jurkovic, D
2015-12-01
Is there any benefit to including the routine examination by ultrasound of the bladder, ureters and kidneys of women with endometriosis? The benefit of examination of the complete urinary tract of women with suspected endometriosis is that ureteric endometriosis, with or without hydronephrosis, can be detected which facilitates early intervention to prevent nephropathy. Women with endometriosis can get ureteric obstruction but there is no clear consensus on the correct diagnostic technique. Ultrasound is accurate at detecting women with bladder endometriosis but ureteric involvement has not been assessed previously. This was a prospective observational study, conducted at a teaching hospital over a period of 14 months. A total of 848 women presenting with chronic pelvic pain were included into the study. All women with chronic pelvic pain underwent a detailed transvaginal and transabdominal pelvic ultrasound examination to investigate possible causes of their symptoms. This included a systematic assessment of the urinary bladder, pelvic sections of the ureters and kidneys. The ultrasound findings were compared with findings at surgery and the results of targeted urological imaging and interventions. A total of 848 women presenting with chronic pelvic pain were included into the study. 28/848 women (3.3% 95% CI 2.1-4.5) had evidence of urinary tract abnormalities on initial ultrasound scan. Among these 17/848 (2.0% 95% CI 1.06-2.94) had evidence of urinary tract endometriosis, whilst 11/848 (1.3% 95% CI 0.54-2.06) women had other urinary tract abnormalities. Among women with urinary tract endometriosis 11/17 (65%) had evidence of ureteric involvement, 3/17 (18%) had both ureteric and bladder disease and 3/17 (18%) had bladder disease only. 12/17 (59%) women with urinary tract endometriosis also had evidence of hydronephrosis. The diagnosis of ureteral endometriosis had a sensitivity of 12/13 (92%) (95% CI 63.9-99.8), specificity 151/151 100% (95% CI 97.6-100), PPV
Blunt abdominal trauma in children.
Schonfeld, Deborah; Lee, Lois K
2012-06-01
This review will examine the current evidence regarding pediatric blunt abdominal trauma and the physical exam findings, laboratory values, and radiographic imaging associated with the diagnosis of intra-abdominal injuries (IAI), as well as review the current literature on pediatric hollow viscus injuries and emergency department disposition after diagnosis. The importance of the seat belt sign on physical examination and screening laboratory data remains controversial, although screening hepatic enzymes are recommended in the evaluation of nonaccidental trauma to identify occult abdominal organ injuries. Focused Assessment with Sonography for Trauma (FAST) has modest sensitivity for hemoperitoneum and IAI in the pediatric trauma patient. Patients with concern for undiagnosed IAI, including bowel injury, may be considered for hospital admission and serial abdominal exams without an increased risk of complications, if an exploratory laparotomy is not performed emergently. Although the FAST exam is not recommended as the sole screening tool to rule out IAI in hemodynamically stable trauma patients, it may be used in conjunction with the physical exam and laboratory findings to identify children at risk for IAI. Children with a normal physical exam and normal abdominal CT may not require routine hospitalization after blunt abdominal trauma.
Novak, Kerri L.; Jacob, Deepti; Kaplan, Gilaad G.; Boyce, Emma; Ghosh, Subrata; Ma, Irene; Lu, Cathy; Wilson, Stephanie; Panaccione, Remo
2016-01-01
Background. Approaches to distinguish inflammatory bowel disease (IBD) from noninflammatory disease that are noninvasive, accurate, and readily available are desirable. Such approaches may decrease time to diagnosis and better utilize limited endoscopic resources. The aim of this study was to evaluate the diagnostic accuracy for gastroenterologist performed point of care ultrasound (POCUS) in the detection of luminal inflammation relative to gold standard ileocolonoscopy. Methods. A prospective, single-center study was conducted on convenience sample of patients presenting with symptoms of diarrhea and/or abdominal pain. Patients were offered POCUS prior to having ileocolonoscopy. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) with 95% confidence intervals (CI), as well as likelihood ratios, were calculated. Results. Fifty-eight patients were included in this study. The overall sensitivity, specificity, PPV, and NPV were 80%, 97.8%, 88.9%, and 95.7%, respectively, with positive and negative likelihood ratios (LR) of 36.8 and 0.20. Conclusion. POCUS can accurately be performed at the bedside to detect transmural inflammation of the intestine. This noninvasive approach may serve to expedite diagnosis, improve allocation of endoscopic resources, and facilitate initiation of appropriate medical therapy. PMID:27446838
Recurrent severe abdominal pain in the pediatric patient.
Homme, James L; Foster, Ashley A
2014-05-01
Ureteropelvic junction obstruction (UPJO) is a blockage occurring at the junction of the ureter and the renal pelvis. Pediatric patients with UPJO pose a diagnostic challenge when they present to the emergency department (ED) with severe recurrent abdominal pain if there is not a level of suspicion for this condition. Our aim was to review presentation of UPJO to the ED, methods of diagnosis, and treatment of this common but often overlooked condition. We report on 2 patients, a 9-year-old and 3-year-old, who had multiple presentations to health care providers and the ED with intermittent and recurrent abdominal pain. Subsequent testing, including ultrasound (US) and computed tomography (CT) with diuretic-recreated symptoms, revealed UPJO. Open pyeloplasty was performed, resulting in complete resolution of symptoms. UPJO is an important diagnosis to consider when patients present to the ED with recurrent abdominal pain. US can be helpful in suspecting the diagnosis, but often CT, magnetic resonance urography, or diuretic scintigraphy is required for confirmation. Diuretics can be used to aid diagnostic testing by reproducing abdominal pain at the time of imaging. Referral to a urologist for open pyeloplasty is definitive treatment for this condition. Copyright © 2014 Elsevier Inc. All rights reserved.
Chen, Hong; Hou, Gary Y; Han, Yang; Payen, Thomas; Palermo, Carmine F; Olive, Kenneth P; Konofagou, Elisa E
2015-09-01
Harmonic motion imaging (HMI) is a radiationforce- based elasticity imaging technique that tracks oscillatory tissue displacements induced by sinusoidal ultrasonic radiation force to assess the resulting oscillatory displacement denoting the underlying tissue stiffness. The objective of this study was to evaluate the feasibility of HMI in pancreatic tumor detection and high-intensity focused ultrasound (HIFU) treatment monitoring. The HMI system consisted of a focused ultrasound transducer, which generated sinusoidal radiation force to induce oscillatory tissue motion at 50 Hz, and a diagnostic ultrasound transducer, which detected the axial tissue displacements based on acquired radio-frequency signals using a 1-D cross-correlation algorithm. For pancreatic tumor detection, HMI images were generated for pancreatic tumors in transgenic mice and normal pancreases in wild-type mice. The obtained HMI images showed a high contrast between normal and malignant pancreases with an average peak-to-peak HMI displacement ratio of 3.2. Histological analysis showed that no tissue damage was associated with HMI when it was used for the sole purpose of elasticity imaging. For pancreatic tumor ablation monitoring, the focused ultrasound transducer was operated at a higher acoustic power and longer pulse length than that used in tumor detection to simultaneously induce HIFU thermal ablation and oscillatory tissue displacements, allowing HMI monitoring without interrupting tumor ablation. HMI monitoring of HIFU ablation found significant decreases in the peak-to-peak HMI displacements before and after HIFU ablation with a reduction rate ranging from 15.8% to 57.0%. The formation of thermal lesions after HIFU exposure was confirmed by histological analysis. This study demonstrated the feasibility of HMI in abdominal tumor detection and HIFU ablation monitoring.
2014-01-01
Background Central venous catheters play an important role in patient care. Real-time ultrasound-guided subclavian central venous (SCV) cannulation may reduce the incidence of complications and the time between skin penetration and the aspiration of venous blood into the syringe. Ultrasonic diagnosis of catheter misplacement and pneumothorax related to central venous catheterization is rapid and accurate. It is unclear, however, whether ultrasound real-time guidance and examination can reduce procedure times and complication rates when compared with landmark guidance and radiographic examination for SCV catheterization. Methods/Design The Subclavian Central Venous Catheters Guidance and Examination by UltraSound (SUBGEUS) study is an investigator-initiated single center, randomized, controlled two-arm trial. Three hundred patients undergoing SCV catheter placement will be randomized to ultrasound real-time guidance and examination or landmark guidance and radiographic examination. The primary outcome is the time between the beginning of the procedure and control of the catheter. Secondary outcomes include the times required for the six components of the total procedure, the occurrence of complications (pneumothorax, hemothorax, or misplacement), failure of the technique and occurrence of central venous catheter infections. Discussion The SUBGEUS trial is the first randomized controlled study to investigate whether ultrasound real-time guidance and examination for SCV catheter placement reduces all procedure times and the rate of complications. Trial registration ClinicalTrials.gov Identifier: NCT01888094 PMID:24885789
Nicolau, A E; Merlan, V; Dinescu, G; Crăciun, M; Kitkani, A; Beuran, M
2012-01-01
Blunt hollow viscus perforations (HVP) due to abdominal contusions (AC), although rare, are difficult to diagnose early and are associated with a high mortality. Our paper analyses retrospectively data from patients operated for HVP between January 2005 and January 2009, the efficiency of different diagnostic tools, mortality and prognostic factors for death. There were 62 patients operated for HVP, 14 of which had isolated abdominal contusion and 48 were poly trauma patients. There were 9 women and 53 men, the mean age was 41.5 years (SD: +17,9), the mean ISS was 32.94 (SD: +15,94), 23 patients had associated solid viscus injuries (SVI). Clinical examination was irelevant for 16 of the 62 patients, abdominal Xray was false negative for 30 out of 35 patients and abdominal ultrasound was false negative for 16 out of 60 patients. Abdominal CT was initially false negative for 7 out of 38 patients: for 4 of them the abdominal CT was repeated and was positive for HVP, for 3 patients a diagnostic laparoscopy was performed. Direct signs for HVP on abdominal CT were present for 3 out of 38 patients. Diagnostic laparoscopy was performed for 7 patients with suspicion for HVP, and was positive for 6 of them and false negative for a patient with a duodenal perforation. Single organ perforations were present in 55 cases, multi organ perforations were present in 7 cases. There were 15 deaths (15.2%), most of them caused by haemodynamic instability (3 out of 6 patients) and associated lesions: SOL for 9 out of 23 cases, pelvic fracture (PF) for 6 out of 14 patients, craniocerebral trauma (CCT) for 12 out of 33 patients.Multivariate analysis showed that the prognostic factors for death were ISS value (p = 0,023) and associated CCT (odds ratio = 4,95; p = 0,017). The following factors were not confirmed as prognostic factors for death: age, haemodynamic instability, associated SVI, thoracic trauma (TT), pelvic fractures (PF), limbs fractures (LF) and admission-operation interval
Focused Ultrasound Lipolysis in the Treatment of Abdominal Cellulite: An Open-Label Study
Moravvej, Hamideh; Akbari, Zahra; Mohammadian, Shahrzad; Razzaghi, Zahra
2015-01-01
Introduction: Despite a growing popularity of noninvasive ultrasonic lipolysis procedure, there is a lack of evidence about the efficacy of this method. This study was performed to evaluate the efficacy of focused ultrasonic lipolysis on abdominal cellulite treatment. Methods: Twenty-eight consecutive subjects (age: 37.8 ± 8 years) underwent weekly transdermal focused ultrasonic lipolysis (Med Contour, General Project Ltd., Florence, Italy) and vacuum drainage for a maximum of eight sessions. Largest abdominal girth and 2 lines at 4 cm to 7 cm distance above and under it were located as fixed points of measurements. The mean value of the three fixed lines was considered as the abdominal circumference. Subjects were evaluated using measurements of circumference, immediately after and 3 weeks after the final treatment and compared using paired t test. Results: One hundred ninety-four ultrasonic lipolysis procedures were performed on 28 subjects. A statistically significant (P < .001) average of 1.89 cm (95% CI: 1.63-2.02 cm) decrease of circumference value was observed in each session of ultrasonic lipolysis. The mean pretreatment to posttreatment circumference reduction was 8.21 cm (95% CI: 6.38-10.04, P < .001) that declined to 7 cm (95% CI: 3.2-10.8, P < .001) at the 3-month follow-up visit. Conclusion: Focused ultrasonic lipolysis appears to be an effective method for reduction of abdominal cellulite, although some amount of circumference reduction reversal may be observed in long term follow-up visit. PMID:26464776
12th WINFOCUS world congress on ultrasound in emergency and critical care.
Acar, Yahya; Tezel, Onur; Salman, Necati; Cevik, Erdem; Algaba-Montes, Margarita; Oviedo-García, Alberto; Patricio-Bordomás, Mayra; Mahmoud, Mustafa Z; Sulieman, Abdelmoneim; Ali, Abbas; Mustafa, Alrayah; Abdelrahman, Ihab; Bahar, Mustafa; Ali, Osama; Lester Kirchner, H; Prosen, Gregor; Anzic, Ajda; Leeson, Paul; Bahreini, Maryam; Rasooli, Fatemeh; Hosseinnejad, Houman; Blecher, Gabriel; Meek, Robert; Egerton-Warburton, Diana; Ćuti, Edina Ćatić; Belina, Stanko; Vančina, Tihomir; Kovačević, Idriz; Rustemović, Nadan; Chang, Ikwan; Lee, Jin Hee; Kwak, Young Ho; Kim, Do Kyun; Cheng, Chi-Yung; Pan, Hsiu-Yung; Kung, Chia-Te; Ćurčić, Ela; Pritišanac, Ena; Planinc, Ivo; Medić, Marijana Grgić; Radonić, Radovan; Fasina, Abiola; Dean, Anthony J; Panebianco, Nova L; Henwood, Patricia S; Fochi, Oliviero; Favarato, Moreno; Bonanomi, Ezio; Tomić, Ivan; Ha, Youngrock; Toh, Hongchuen; Harmon, Elizabeth; Chan, Wilma; Baston, Cameron; Morrison, Gail; Shofer, Frances; Hua, Angela; Kim, Sharon; Tsung, James; Gunaydin, Isa; Kekec, Zeynep; Ay, Mehmet Oguzhan; Kim, Jinjoo; Kim, Jinhyun; Choi, Gyoosung; Shim, Dowon; Lee, Ji-Han; Ambrozic, Jana; Prokselj, Katja; Lucovnik, Miha; Simenc, Gabrijela Brzan; Mačiulienė, Asta; Maleckas, Almantas; Kriščiukaitis, Algimantas; Mačiulis, Vytautas; Macas, Andrius; Mohite, Sharad; Narancsik, Zoltan; Možina, Hugon; Nikolić, Sara; Hansel, Jan; Petrovčič, Rok; Mršić, Una; Orlob, Simon; Lerchbaumer, Markus; Schönegger, Niklas; Kaufmann, Reinhard; Pan, Chun-I; Wu, Chien-Hung; Pasquale, Sarah; Doniger, Stephanie J; Yellin, Sharon; Chiricolo, Gerardo; Potisek, Maja; Drnovšek, Borut; Leskovar, Boštjan; Robinson, Kristine; Kraft, Clara; Moser, Benjamin; Davis, Stephen; Layman, Shelley; Sayeed, Yusef; Minardi, Joseph; Pasic, Irmina Sefic; Dzananovic, Amra; Pasic, Anes; Zubovic, Sandra Vegar; Hauptman, Ana Godan; Brajkovic, Ana Vujaklija; Babel, Jaksa; Peklic, Marina; Radonic, Vedran; Bielen, Luka; Ming, Peh Wee; Yezid, Nur Hafiza; Mohammed, Fatahul Laham; Huda, Zainal Abidin; Ismail, Wan Nasarudin Wan; Isa, W Yus Haniff W; Fauzi, Hashairi; Seeva, Praveena; Mazlan, Mohd Zulfakar
2016-09-01
A1 Point-of-care ultrasound examination of cervical spine in emergency departmentYahya Acar, Onur Tezel, Necati SalmanA2 A new technique in verifying the placement of a nasogastric tube: obtaining the longitudinal view of nasogastric tube in addition to transverse view with ultrasoundYahya Acar, Necati Salman, Onur Tezel, Erdem CevikA3 Pseudoaneurysm of the femoral artery after cannulation of a central venous line. Should we always use ultrasound in these procedures?Margarita Algaba-Montes, Alberto Oviedo-García, Mayra Patricio-BordomásA4 Ultrasound-guided supraclavicular subclavian vein catheterization. A novel approach in emergency departmentMargarita Algaba-Montes, Alberto Oviedo-García, Mayra Patricio-BordomásA5 Clinical ultrasound in a septic and jaundice patient in the emergency departmentMargarita Algaba-Montes, Alberto Oviedo-García, Mayra Patricio-BordomásA6 Characterization of the eyes in preoperative cataract Saudi patients by using medical diagnostic ultrasoundMustafa Z. Mahmoud, Abdelmoneim SuliemanA7 High-frequency ultrasound in determining the causes of acute shoulder joint painMustafa Z. MahmoudA8 Teaching WINFOCUS Ultrasound Life Support Basic Level 1 for Providers in resource-limited countriesAbbas Ali, Alrayah Mustafa, Ihab Abdelrahman, Mustafa Bahar, Osama Ali, H. Lester Kirchner, Gregor ProsenA9 Changes of arterial stiffness and endothelial function during uncomplicated pregnancyAjda Anzic, Paul LeesonA10 Cardiovascular haemodynamic properties before, during and after pregnancyAjda Anzic, Paul LeesonA11 An old man with generalized weaknessMaryam Bahreini, Fatemeh RasooliA12 Ultrasonography for non-specific presentations of abdominal painMaryam Bahreini, Houman HosseinnejadA13 Introduction of a new imaging guideline for suspected renal colic in the emergency department: effect on CT Urogram utilisationGabriel Blecher, Robert Meek, Diana Egerton-WarburtonA14 Transabdominal ultrasound screening for pancreatic cancer in Croatian military
[Carpal canal ultrasound examination in patients with mild hand-arm vibration disease].
Liu, Y Z; Ye, Z H; Yang, W L; Zhu, J X; Lu, Q J; Su, W L
2016-08-20
Objective: To investigate the clinical value of ultrasound examination of carpal canal structure in patients with mild hand-arm vibration disease. Methods: A total of 29 patients (58 wrists) with mild hand-arm vibration disease who were treated in Shenzhen Prevention and Treatment Center for Occupational Diseases from May to December, 2015 were enrolled as observation group, and 20 healthy volunteers (40 wrists) were enrolled as the control group. Color Doppler ultrasound was used to observe the morphology and echo of the median nerve in the carpal canal and 9 muscle tendons and transverse carpal ligament. The thickness of transverse carpal ligament and diameter of the median nerve at the level of the hamulus of hamate bone were measured, as well as the cross-sectional area of the median nerve at the level of pisiform bone. Results: In the 29 patients with hand-arm vibration disease patients in the observation group, 8 experienced entrapment of the median nerve in the carpal canal, among whom 5 had entrapment in both wrists; there were 13 wrists (23%) with nerve entrapment and 45 wrists (77%) without nerve entrapment. Compared with the control group, the patients with hand-arm vibration disease and nerve entrapment in the observation group showed significant thickening of the transverse carpal ligament at the level of the hamulus of hamate bone and a significant increase in the cross-sectional area of the median nerve at the level of pisiform bone ( P <0.05) , while there were no significant differences in the thickness of transverse carpal ligament at the level of the hamulus of hamate bone and the cross-sectional area of the median nerve at the level of pisiform bone ( t=- 9.397 and -4.385, both P >0.05) . Conclusion: Ultrasound examination can clearly show the radiological changes of carpal canal contents in patients with mild hand-arm vibration disease and has a certain diagnostic value in nerve damage in patients with hand-arm vibration disease.
New heights in ultrasound: first report of spinal ultrasound from the international space station.
Marshburn, Thomas H; Hadfield, Chris A; Sargsyan, Ashot E; Garcia, Kathleen; Ebert, Douglas; Dulchavsky, Scott A
2014-01-01
Changes in the lumbar and sacral spine occur with exposure to microgravity in astronauts; monitoring these alterations without radiographic capabilities on the International Space Station (ISS) requires novel diagnostic solutions to be developed. We evaluated the ability of point-of-care ultrasound, performed by nonexpert-operator astronauts, to provide accurate anatomic information about the spine in long-duration crewmembers in space. Astronauts received brief ultrasound instruction on the ground and performed in-flight cervical and lumbosacral ultrasound examinations using just-in-time training and remote expert tele-ultrasound guidance. Ultrasound examinations on the ISS used a portable ultrasound device with real-time communication/guidance with ground experts in Mission Control. The crewmembers were able to obtain diagnostic-quality examinations of the cervical and lumbar spine that would provide essential information about acute or chronic changes to the spine. Spinal ultrasound provides essential anatomic information in the cervical and lumbosacral spine; this technique may be extensible to point-of-care situations in emergency departments or resource-challenged areas without direct access to additional radiologic capabilities. Copyright © 2014 Elsevier Inc. All rights reserved.
Spalgais, Sonam; Agarwal, Upasna; Sarin, Rohit; Chauhan, Devesh; Yadav, Anita; Jaiswal, Anand
2017-05-18
High proportion of TB in people living with HIV (PLHIV) is undiagnosed. Due to this active TB case finding is recommended for HIV clinics in high TB burden countries. Presently sputum examination and chest radiography are frontline tests recommended for HIV infected TB presumptives. Abdominal TB which occurs frequently in PLHIV may be missed even by existing programmatic intensified case finding protocols. This study evaluated the routine use of ultrasonography (USG) for active case finding of abdominal TB in HIV clinics. Retrospective analysis of eight years' data from an HIV Clinic in a TB hospital in India. Patients underwent chest x-ray, sputum examination, USG abdomen and routine blood tests at entry to HIV care. Case forms were scrutinized for diagnosis of TB, USG findings and CD4 cell counts. Abdominal TB was classified as probable or possible TB. Probable TB was based on presence of two major USG (abdomen) findings suggestive of active TB, or one major USG finding with at least two minor USG findings or at least two symptoms, or any USG finding with microbiologically confirmed active TB at another site. Possible TB was based on the presence of one major USG finding, or the presence of two minor USG findings with at least two symptoms. Bacteriological confirmation was not obtained. Eight hundred and eighty-nine people PLHIV underwent a baseline USG abdomen. One hundred and thirteen of 340 cases already diagnosed with TB and 87 of the 91 newly diagnosed with TB at time of HIV clinic registration had abdominal TB. Non-abdominal symptoms like weight loss, fever and cough were seen in 53% and 22% cases had no symptoms at all. Enlarged abdominal lymph nodes with central caseation, ascitis, splenic microabsesses, bowel thickening and hepatosplenomegaly were the USG findings in these cases. Abdominal TB is a frequent TB site in PLHIV presenting with non-abdominal symptoms. It can be easily detected on basis of features seen on a simple abdominal ultrasound
Kirkpatrick, A W; Nickerson, D; Roberts, D J; Rosen, M J; McBeth, P B; Petro, C C; Berrevoet, Frederik; Sugrue, M; Xiao, Jimmy; Ball, C G
2017-06-01
Reconstruction with reconstitution of the container function of the abdominal compartment is increasingly being performed in patients with massive ventral hernia previously deemed inoperable. This situation places patients at great risk of severe intra-abdominal hypertension and abdominal compartment syndrome if organ failure ensues. Intra-abdominal hypertension and especially abdominal compartment syndrome may be devastating systemic complications with systematic and progressive organ failure and death. We thus reviewed the pathophysiology and reported clinical experiences with abnormalities of intra-abdominal pressure in the context of abdominal wall reconstruction. Bibliographic databases (1950-2015), websites, textbooks, and the bibliographies of previously recovered articles for reports or data relating to intra-abdominal pressure, intra-abdominal hypertension, and the abdominal compartment syndrome in relation to ventral, incisional, or abdominal hernia repair or abdominal wall reconstruction. Surgeons should thus consider and carefully measure intra-abdominal pressure and its resultant effects on respiratory parameters and function during abdominal wall reconstruction. The intra-abdominal pressure post-operatively will be a result of the new intra-peritoneal volume and the abdominal wall compliance. Strategies surgeons may utilize to ameliorate intra-abdominal pressure rise after abdominal wall reconstruction including temporizing paralysis of the musculature either temporarily or semi-permanently, pre-operative progressive pneumoperitoneum, permanently removing visceral contents, or surgically releasing the musculature to increase the abdominal container volume. In patients without complicating shock and inflammation, and in whom the abdominal wall anatomy has been so functionally adapted to maximize compliance, intra-abdominal hypertension may be transient and tolerable. Intra-abdominal hypertension/abdominal compartment syndrome in the specific setting of
Ko, Seok-Jae; Lee, Hyunju; Kim, Seul-Ki; Kim, Minji; Kim, Jinsung; Lee, Beom-Joon; Park, Jae-Woo
2015-06-01
Abdominal examination (AE) is the evaluation of the status of illness by examining the abdominal region in traditional Korean medicine (TKM). Although AE is currently considered an important diagnostic method in TKM, owing to its clinical usage, no studies have been conducted to objectively assess its accuracy and develop standards. Twelve healthy subjects and 21 patients with functional dyspepsia have participated in this study. The patients were classified into epigastric discomfort group (n=11) and epigastric discomfort with tenderness group (n=10) according to the clinical diagnosis by AE. After evaluating the subjective epigastric discomfort in all subjects, two independent clinicians measured the pressure pain threshold (PPT) two times at an acupoint (CV 14) using an algometer. We then assessed the interrater and intrarater reliability of the PPT measurements and evaluated the validity (sensitivity and specificity) via a receiver operating characteristic plot and optimal cutoff value. The results of the interrater reliability test showed a very strong correlation (correlation coefficient range: 0.82-0.91). The results of intrarater reliability test also showed a higher than average correlation (intraclass correlation coefficient: 0.58-0.70). The optimal cutoff value of PPT in the epigastric area was 1.8 kg/cm(2) with 100% sensitivity and 54.54% specificity. PPT measurements in the epigastric area with an algometer demonstrated high reliability and validity for AE, which makes this approach potentially useful in clinical applications as a new quantitative measurement in TKM.
Abdelsalam, Khaled; Mohamdin, O W
2016-01-01
Regional anesthetic techniques can be used to alleviate postoperative pain in patients undergoing major upper abdominal surgery. Our aim was to evaluate the efficacy of bilateral ultrasound (US)-guided rectus sheath (RS) and transversus abdominis plane (TAP) blocks for better perioperative analgesia. It is a prospective, observer-blinded, randomized clinical study. 40 eligible patients undergoing elective liver resection or Whipple procedure were included. All patients received a standardized anesthetic technique. Group 1 (n = 20) received preincisional US-guided bilateral RS and TAP blocks using 20 ml volume of bupivacaine 0.25% for each, and group 2 (n = 20) received local wound infiltration at end of surgery with 40 ml of bupivacaine 0.25%. A standardized postoperative analgesic regimen composed of intravenous paracetamol and a morphine patient-controlled analgesia (PCA). The use of intraoperative fentanyl and recovery room morphine boluses, PCA-administered morphine, pain scores as well as number of patients' experienced postoperative nausea and vomiting in the ward at 6 and 24 h were recorded. Group 1 patients received a significantly lower cumulative intraoperative fentanyl, significantly lesser boluses of morphine in postanesthesia care unit, as well, significantly lower cumulative 24 h postoperative morphine dosage than the group 2 patients. Pain visual analog scale scores were significantly lower at both 6 and 24 h postoperatively in TAP group when compared with the no-TAP group. There were no complications related to the TAP block procedures. No signs or symptoms of local anesthetic systemic toxicity were detected. The combination of bilateral US-guided RS and TAP blocks provides excellent perioperative analgesia for major upper abdominal surgery.
[Hepatic artery pseudoaneurysm following blunt abdominal injury].
Kargl, S; Breitwieser, J; Gitter, R; Pumberger, W
2012-12-01
Posttraumatic hepatic artery pseudoaneurysms are a rare but life-threatening complication of blunt abdominal trauma with liver damage. We report the case of a child who developed a pseudoaneurysm of the right hepatic artery after a bicycle accident with central liver rupture. After an episode of hemodynamically relevant hemobilia due to delayed bleeding, the asymptomatic pseudoaneurysm was diagnosed coincidentally by ultrasound. Because of the progression in size angiographic coiling was performed and led to thrombotic occlusion of the pseudoaneurysm. After a symptom-free period of 1 month the child required surgery because of acute cholecystitis.
Batagini, Nayara Cioffi; Ventura, Carlos Augusto Pinto; Raghavan, Madhavan L; Chammas, Maria Cristina; Tachibana, Adriano; da Silva, Erasmo Simão
2016-06-01
The objective was to demonstrate the ability of ultrasound (US) with 3D properties to evaluate volumetry and biomechanical parameters of the aorta in patients with and without abdominal aortic aneurysm (AAA). Thirty-one patients with normal aortas (group 1), 46 patients with AAA measuring 3.0-5.5 cm (group 2) and 31 patients with AAA ⩾ 5.5 cm (group 3) underwent a 2D/3D-US examination of the infra-renal aorta, and the images were post-processed prior to being analyzed. In the maximum diameter, the global circumferential strain and the global maximum rotation assessed by 2D speckle-tracking algorithms were compared among the three groups. The volumetry data obtained using 3D-US from 40 AAA patients were compared with the volumetry data obtained by a contemporary computed tomography (CT) scan. The median global circumferential strain was 2.0% (interquartile range (IR): 1.0-3.0), 1.0% (IR: 1.0-2.0) and 1.0% (IR: 1.0-1.75) in groups 1, 2 and 3, respectively (p < 0.001). The median global maximum rotation decreased progressively from group 1 to group 3 (1.38º (IR: 0.77-2.13), 0.80º (IR: 0.57-1.0) and 0.50º (IR: 0.31-0.75), p < 0.001). AAA volume estimations by 3D-US correlated well with CT (R(2) = 0.76). In conclusion, US with 3D properties is non-invasive and has the potential to evaluate volumetry and biomechanical characteristics of AAA. © The Author(s) 2016.
An integrated model-based software for FUS in moving abdominal organs.
Schwenke, Michael; Strehlow, Jan; Haase, Sabrina; Jenne, Juergen; Tanner, Christine; Langø, Thomas; Loeve, Arjo J; Karakitsios, Ioannis; Xiao, Xu; Levy, Yoav; Sat, Giora; Bezzi, Mario; Braunewell, Stefan; Guenther, Matthias; Melzer, Andreas; Preusser, Tobias
2015-05-01
Focused ultrasound surgery (FUS) is a non-invasive method for tissue ablation that has the potential for complete and controlled local tumour destruction with minimal side effects. The treatment of abdominal organs such as the liver, however, requires particular technological support in order to enable a safe, efficient and effective treatment. As FUS is applied from outside the patient's body, suitable imaging methods, such as magnetic resonance imaging or diagnostic ultrasound, are needed to guide and track the procedure. To facilitate an efficient FUS procedure in the liver, the organ motion during breathing and the partial occlusion by the rib cage need to be taken into account in real time, demanding a continuous patient-specific adaptation of the treatment configuration. Modelling the patient's respiratory motion and combining this with tracking data improves the accuracy of motion predictions. Modelling and simulation of the FUS effects within the body allows the use of treatment planning and has the potential to be used within therapy to increase knowledge about the patient status. This article describes integrated model-based software for patient-specific modelling and prediction for FUS treatments of moving abdominal organs.
An ergonomic, instrumented ultrasound probe for 6-axis force/torque measurement.
Gilbertson, Matthew W; Anthony, Brian W
2013-01-01
An ergonomic, instrumented ultrasound probe has been developed for medical imaging applications. The device, which fits compactly in the hand of sonographers and permits rapid attachment & removal of the ultrasound probe, measures ultrasound probe-to-patient contact forces and torques in all six axes. The device was used to measure contact forces and torques applied by ten professional sonographers on five patients during thirty-six abdominal exams. Of the three contact forces, those applied along the probe axis were found to be largest, averaging 7.0N. Measurement noise was quantified for each axis, and found to be small compared with the axial force. Understanding the range of forces applied during ultrasound imaging enables the design of more accurate robotic imaging systems and could also improve understanding of the correlation between contact force and sonographer fatigue and injury.
Leroy, Sandrine; M'Zali, Fatima; Kann, Michael; Weber, David J; Smith, David D
2014-12-01
The risk of cross-infection from shared ultrasound probes in endorectal and vaginal ultrasonography due to low-level disinfection (LLD) is difficult to estimate because potential infections are also sexually transmitted diseases, and route of contamination is often difficult to establish. In France, the widely used standard for prevention of infections is through the use of probe covers and LLD of the ultrasound transducer by disinfectant wipes. We performed an in silico simulation based on a systematic review to estimate the number of patients infected after endorectal or vaginal ultrasonography examination using LLD for probes. We performed a stochastic Monte Carlo computer simulation to produce hypothetical cohorts for a population of 4 million annual ultrasound examinations performed in France, and we estimated the number of infected patients for human immunodeficiency virus (HIV), herpes simplex virus, hepatitis B virus, hepatitis C virus, human papilloma virus, cytomegalovirus, and Chlamydia trachomatis. Modeling parameters were estimated by meta-analysis when possible. The probability of infection from a contaminated probe ranged from 1% to 6%, depending on the pathogen. For cases of HIV infection, this would result in approximately 60 infected patients per year. For other common viral infections, the number of new cases ranged from 1,600 to 15,000 per year that could be attributable directly to ultrasound and LLD procedures. Our simulation results showed that, despite cumulative use of probe cover and LLD, there were still some cases of de novo infection that may be attributable to ultrasound procedures. These cases are preventable by reviewing the currently used LLD and/or upgrading LLD to high-level disinfection, as recommended by the US Centers for Disease Control and Prevention.
Abdominal shotgun trauma: A case report
Toutouzas, Konstantinos G; Larentzakis, Andreas; Drimousis, Panagiotis; Riga, Maria; Theodorou, Dimitrios; Katsaragakis, Stylianos
2008-01-01
Introduction One of the most lethal mechanisms of injury is shotgun wound and particularly the abdominal one. Case presentation We report a case of a 45 years old male suffering abdominal shotgun trauma, who survived his injuries. Conclusion The management of the abdominal shotgun wounds is mainly dependent on clinical examination and clinical judgment, while requires advanced surgical skills. PMID:18625076
[Could we perform quality second trimester ultrasound among obese pregnant women?].
Fuchs, F; Voulgaropoulos, A; Houllier, M; Senat, M-V
2013-05-01
To compare the quality of second trimester ultrasound images and their anatomical quality scores among obese women and those with a normal body mass index (BMI). This prospective study, which took place from 2009 to 2011, included every obese pregnant woman (prepregnancy BMI greater than 30 kg/m(2)) who had an ultrasound examination at 20 to 24 weeks in our hospital and a control group with a normal BMI (20-24.9kg/m(2)) who had the same examination. A single operator evaluated the quality of all images, reviewing the standardized ultrasound planes - three biometric and six anatomical - required by French guidelines and scoring the quality of the six anatomical images. Each image was assessed according to 4-6 criteria, each worth one point. We sought excellent quality, defined as the frequency of maximum points for a given image. The obese group included 223 women and the control group 60. The completion rate for each image was at least 95 % in the control group and 90 % in the obese group, except for diaphragm and right outflow tract images. Overall, the excellence rate varied from 35 % to 92 % in the normal BMI group and 18 % to 58 % in the obese group and was significantly lower in the latter for all images except abdominal circumference (P=0.26) and the spine (P=0.06). Anatomical quality scores were also significantly lower in the obese group (22.3 vs. 27.2 ; P=0.001). Image quality and global anatomical scores in second trimester ultrasound scans were significantly lower among obese than normal-weight women. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Appendicitis following blunt abdominal trauma.
Cobb, Travis
2017-09-01
Appendicitis is a frequently encountered surgical problem in the Emergency Department (ED). Appendicitis typically results from obstruction of the appendiceal lumen, although trauma has been reported as an infrequent cause of acute appendicitis. Intestinal injury and hollow viscus injury following blunt abdominal trauma are well reported in the literature but traumatic appendicitis is much less common. The pathophysiology is uncertain but likely results from several mechanisms, either in isolation or combination. These include direct compression/crush injury, shearing injury, or from indirect obstruction of the appendiceal lumen by an ileocecal hematoma or traumatic impaction of stool into the appendix. Presentation typically mirrors that of non-traumatic appendicitis with nausea, anorexia, fever, and right lower quadrant abdominal tenderness and/or peritonitis. Evaluation for traumatic appendicitis requires a careful history and physical exam. Imaging with ultrasound or computed tomography is recommended if the history and physical do not reveal an acute surgical indication. Treatment includes intravenous antibiotics and surgical consultation for appendectomy. This case highlights a patient who developed acute appendicitis following blunt trauma to the abdomen sustained during a motor vehicle accident. Appendicitis must be considered as part of the differential diagnosis in any patient who presents to the ED with abdominal pain, including those whose pain begins after sustaining blunt trauma to the abdomen. Because appendicitis following trauma is uncommon, timely diagnosis requires a high index of suspicion. Copyright © 2017 Elsevier Inc. All rights reserved.
High Intensity Focused Ultrasound Tumor Therapy System and Its Application
NASA Astrophysics Data System (ADS)
Sun, Fucheng; He, Ye; Li, Rui
2007-05-01
At the end of last century, a High Intensity Focused Ultrasound (HIFU) tumor therapy system was successfully developed and manufactured in China, which has been already applied to clinical therapy. This article aims to discuss the HIFU therapy system and its application. Detailed research includes the following: power amplifiers for high-power ultrasound, ultrasound transducers with large apertures, accurate 3-D mechanical drives, a software control system (both high-voltage control and low-voltage control), and the B-mode ultrasonic diagnostic equipment used for treatment monitoring. Research on the dosage of ultrasound required for tumour therapy in multiple human cases has made it possible to relate a dosage formula, presented in this paper, to other significant parameters such as the volume of thermal tumor solidification, the acoustic intensity (I), and the ultrasound emission time (tn). Moreover, the HIFU therapy system can be applied to the clinical treatment of both benign and malignant tumors in the pelvic and abdominal cavity, such as uterine fibroids, liver cancer and pancreatic carcinoma.
How I Manage Abdominal Injuries.
ERIC Educational Resources Information Center
Haycock, Christine E.
1986-01-01
In sports, abdominal injuries occur most frequently in cycling, horseback riding, and skiing. Most involve children, not adults. Any athlete sustaining a severe blow to the abdomen should be examined. Guidelines are provided for recognizing and treating injuries to the abdominal muscles, kidneys, spleen, and liver. (Author/MT)
Abdominal hernias: Radiological features
Lassandro, Francesco; Iasiello, Francesca; Pizza, Nunzia Luisa; Valente, Tullio; Stefano, Maria Luisa Mangoni di Santo; Grassi, Roberto; Muto, Roberto
2011-01-01
Abdominal wall hernias are common diseases of the abdomen with a global incidence approximately 4%-5%. They are distinguished in external, diaphragmatic and internal hernias on the basis of their localisation. Groin hernias are the most common with a prevalence of 75%, followed by femoral (15%) and umbilical (8%). There is a higher prevalence in males (M:F, 8:1). Diagnosis is usually made on physical examination. However, clinical diagnosis may be difficult, especially in patients with obesity, pain or abdominal wall scarring. In these cases, abdominal imaging may be the first clue to the correct diagnosis and to confirm suspected complications. Different imaging modalities are used: conventional radiographs or barium studies, ultrasonography and Computed Tomography. Imaging modalities can aid in the differential diagnosis of palpable abdominal wall masses and can help to define hernial contents such as fatty tissue, bowel, other organs or fluid. This work focuses on the main radiological findings of abdominal herniations. PMID:21860678
Patients with abdominal aortic aneurysm have a high prevalence of popliteal artery aneurysms.
Tuveson, Viktoria; Löfdahl, Hedvig E; Hultgren, Rebecka
2016-08-01
Patients with abdominal aortic aneurysms (AAA) are more prone to develop popliteal artery aneurysms (PAA), but the prevalence is not well known. Our aim was to investigate the prevalence of PAA in patients with AAA, and to determine whether a certain risk factor profile is more commonly found in patients with concurrent aneurysms. All AAA patients (ICD code I71.3, I71.4) attending the outpatient clinic at the Karolinska University Hospital between 2011 and 2013 were included in the study cohort (n=465); 48% (225) had been subjected to an ultrasound or computed tomography scan of their popliteal arteries. In these patients, three definitions of PAA were considered (⩾ 10.5, ⩾ 12, ⩾ 15 mm), although the overall analysis is based on PAA ⩾ 12 mm. The mean age was 70.7 years (SD 7.5), 89% were men, and the mean AAA diameter was 47 mm (SD 14). The prevalence of PAA was 19% (n=43) by definition ⩾ 12 mm, and 11% (n=25) with 15 mm. Claudication was more frequently found in AAA patients with PAA than patients without PAA. Sensitivity between clinical examination and radiology was 26%, and the specificity for clinical examination was 90%. In conclusion, owing to the high prevalence of PAA in AAA patients, described by us and others, the low cost and risks associated with ultrasound and the poor sensitivity at clinical examination, all women and men with AAA should undergo one radiological examination of their popliteal arteries. © The Author(s) 2016.
Chen, Hung-Yuan; Lin, Chien-Chu; Chiu, Yen-Ling; Hsu, Shih-Ping; Pai, Mei-Fen; Yang, Ju-Yeh; Wu, Hon-Yen; Peng, Yu-Sen
2014-01-01
The liver fat contents and abdominal adiposity correlate well with insulin resistance (IR) in the general population. However, the relationship between liver fat content, abdominal adiposity and IR in non-diabetic hemodialysis (HD) patients remains unclear. This study aimed to clarify the associations among these factors. This is a cross-sectional, observational study. All patients received abdominal ultrasound for liver fat content. Abdominal adiposity was quantified with the conicity index (Ci) and waist circumference (WC). We checked the homeostasis model assessment for insulin resistance index (HOMA-IR) for IR. A total of 112 patients (60 women) were analyzed. Subjects with higher liver fat contents and WC had higher IR indices. But Ci did not correlate with IR indices. In both the multi-variable linear regression model and the logistic regression model, only higher liver fat content predicted a severe IR status. Liver fat contents have a remarkable correlation with IR; however, abdominal adiposity, measured either by Ci or WC, dose not independently correlate with IR in non-diabetic prevalent HD patients. © 2014 S. Karger AG, Basel.
Chronic Contained Rupture of an Abdominal Aortic Aneurysm: From Diagnosis to Endovascular Resolution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gandini, Roberto, E-mail: marcello.chiocchi@fastwebnet.it; Chiocchi, Marcello; Maresca, Luciano
2008-07-15
A male patient, 69 years old, presented with fever, leucocytosis, and persistent low back pain; he also had an abdominal aortic aneurysm (AAA), as previously diagnosed by Doppler UltraSound (US), and was admitted to our hospital. On multislice computed tomography (msCT), a large abdominal mass having no definite border and involving the aorta and both of the psoas muscles was seen. This mass involved the forth-lumbar vertebra with lysis, thus simulating AAA rupture into a paraspinal collection; it was initially considered a paraspinal abscess. After magnetic resonance imaging examination and culture of the fluid aspirated from the mass, no infectivemore » organisms were found; therefore, a diagnosisof chronically contained AAA rupture was made, and an aortic endoprosthesis was subsequently implanted. The patient was discharged with decreased lumbar pain. At 12-month follow-up, no evidence of leakage was observed. To our knowledge, this is the first case of endoprosthesis implantation in a patient, who was a poor candidate for surgical intervention due to renal failure, leucocytosis and high fever, having a chronically contained AAA ruptured simulatingspodilodiscitis abscess. Appropriate diagnosis and therapy resolved potentially crippling pathology and avoided surgical graft-related complications.« less
Ma, Irene W Y; Arishenkoff, Shane; Wiseman, Jeffrey; Desy, Janeve; Ailon, Jonathan; Martin, Leslie; Otremba, Mirek; Halman, Samantha; Willemot, Patrick; Blouw, Marcus
2017-09-01
Bedside point-of-care ultrasound (POCUS) is increasingly used to assess medical patients. At present, no consensus exists for what POCUS curriculum is appropriate for internal medicine residency training programs. This document details the consensus-based recommendations by the Canadian Internal Medicine Ultrasound (CIMUS) group, comprising 39 members, representing 14 institutions across Canada. Guiding principles for selecting curricular content were determined a priori. Consensus was defined as agreement by at least 80% of the members on POCUS applications deemed appropriate for teaching and assessment of trainees in the core (internal medicine postgraduate years [PGY] 1-3) and expanded (general internal medicine PGY 4-5) training programs. We recommend four POCUS applications for the core PGY 1-3 curriculum (inferior vena cava, lung B lines, pleural effusion, and abdominal free fluid) and three ultrasound-guided procedures (central venous catheterization, thoracentesis, and paracentesis). For the expanded PGY 4-5 curriculum, we recommend an additional seven applications (internal jugular vein, lung consolidation, pneumothorax, knee effusion, gross left ventricular systolic function, pericardial effusion, and right ventricular strain) and four ultrasound-guided procedures (knee arthrocentesis, arterial line insertion, arterial blood gas sampling, and peripheral venous catheterization). These recommendations will provide a framework for training programs at a national level.
Comparison of lateral abdominal muscle thickness between weightlifters and matched controls.
Sitilertpisan, Patraporn; Pirunsan, Ubon; Puangmali, Aatit; Ratanapinunchai, Jonjin; Kiatwattanacharoen, Suchart; Neamin, Hudsaleark; Laskin, James J
2011-11-01
To compare lateral abdominal muscle thickness between weightlifters and matched controls. A case control study design. University laboratory. 16 female Thai national weightlifters and 16 matched controls participated in this study. Ultrasound imaging with a 12-MHz linear array was used to measure the resting thickness of transversus abdominis (TrA), internal oblique (IO) and total thickness (Total) of lateral abdominal muscle (LAM) on the right side of abdominal wall. The absolute muscle thickness and the relative contribution of each muscle to the total thickness were determined. Weightlifters had significantly thicker absolute TrA and IO muscles than matched controls (p < 0.01). Further, the relative thickness of the IO was significantly greater in weightlifters than matched controls (p < 0.05). The findings of this study suggest that routine Olympic style weight training among female weightlifters appears to result in preferential hypertrophy or adaptation of the IO muscle. Copyright © 2011 Elsevier Ltd. All rights reserved.
Matalon, Shanna A; Askari, Reza; Gates, Jonathan D; Patel, Ketan; Sodickson, Aaron D; Khurana, Bharti
2017-01-01
Abdominal wall injuries occur in nearly one of 10 patients coming to the emergency department after nonpenetrating trauma. Injuries range from minor, such as abdominal wall contusion, to severe, such as abdominal wall rupture with evisceration of abdominal contents. Examples of specific injuries that can be detected at cross-sectional imaging include abdominal muscle strain, tear, or hematoma, including rectus sheath hematoma (RSH); traumatic abdominal wall hernia (TAWH); and Morel-Lavallée lesion (MLL) (closed degloving injury). These injuries are often overlooked clinically because of (a) a lack of findings at physical examination or (b) distraction by more-severe associated injuries. However, these injuries are important to detect because they are highly associated with potentially grave visceral and vascular injuries, such as aortic injury, and because their detection can lead to the diagnosis of these more clinically important grave traumatic injuries. Failure to make a timely diagnosis can result in delayed complications, such as bowel hernia with potential for obstruction or strangulation, or misdiagnosis of an abdominal wall neoplasm. Groin injuries, such as athletic pubalgia, and inferior costochondral injuries should also be considered in patients with abdominal pain after nonpenetrating trauma, because these conditions may manifest with referred abdominal pain and are often included within the field of view at cross-sectional abdominal imaging. Radiologists must recognize and report acute abdominal wall injuries and their associated intra-abdominal pathologic conditions to allow appropriate and timely treatment. © RSNA, 2017.
Assessment of the accuracy of AortaScan for detection of abdominal aortic aneurysm (AAA).
Abbas, A; Smith, A; Cecelja, M; Waltham, M
2012-02-01
AortaScan AMI 9700 is a portable 3D ultrasound device that automatically measures the maximum diameter of the abdominal aorta without the need for a trained sonographer. It is designed to rapidly diagnose or exclude an AAA and may have particular use in screening programs. Our objective was to determine its accuracy to detect AAA. Subjects from our AAA screening and surveillance programs were examined. The aorta was scanned using the AortaScan and computed tomography (CT). Ninety-one subjects underwent imaging (44 AAA on conventional ultrasound surveillance and 47 controls). The largest measurement obtained by AortaScan was compared against the CT-aortic measurement. The mean aortic diameter was 2.8 cm. The CT scan confirmed the diagnosis of AAA in 43 subjects. There was one false positive measurement on conventional ultrasound. AortaScan missed the diagnosis of AAA in eight subjects. There were thirteen false positive measurements. The sensitivity, specificity, positive and negative predictive values were 81%, 72%, 72% and 81% respectively. A device to detect AAA without the need for a trained operator would have potential in a community-based screening programme. The AortaScan, however, lacks adequate sensitivity and significant technical improvement is necessary before it could be considered a replacement for trained screening personnel. Copyright © 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Source Book of Educational Materials for Diagnostic Medical Ultrasound. Radiological Health Series.
ERIC Educational Resources Information Center
Pijar, Mary Lou, Comp; And Others
This report is a compilation of educational materials that are available in the field of diagnostic medical ultrasound. Materials, which include publications, audiovisual aids, and teaching aids, are listed under the following categories: abdominal imaging; anatomy and physiology; anatomy and embryology; bioeffects; cardiology and vasculature;…
Demin, D B; Laĭkov, A V; Funygin, M S; Chegodaeva, A A; Solodov, Iu Iu; Butina, K V
2014-01-01
The article presents a low-invasive method in the intraoperative ultrasound-guided surgery. The method had several steps: an access (2-3 cm) was made to a liquid formation with the following aspiration of contents, a necrotic detritus was removed through the wound tract using simultaneous ultrasound examination of efficacy of emptying the cavity with drainage. This means allowed the performance of single-stage sanitization and drainage of cavity formations, which contained the liquid and dense necrotic tissues in the lumen. The method was effective, technically workable in any surgical hospital. At the same time, it was economically reasonable, because there wasn't need to buy an additional equipment. The application of the means considerably shortened a hospital stay and the lethality was reduced.
Ultrasound Applied to Subcutaneous Fat Tissue Measurements in International Elite Canoeists.
Kopinski, S; Engel, T; Cassel, M; Fröhlich, K; Mayer, F; Carlsohn, A
2015-12-01
Subcutaneous adipose tissue (SAT) measurements with ultrasound have recently been introduced to assess body fat in elite athletes. However, appropriate protocols and data on various groups of athletes are missing. We investigated intra-rater reliability of SAT measurements using ultrasound in elite canoe athletes. 25 international level canoeists (18 male, 7 female; 23±4 years; 81±11 kg; 1.83±0.09 m; 20±3 training h/wk) were measured on 2 consecutive days. SAT was assessed with B-mode ultrasound at 8 sites (ISAK): triceps, subscapular, biceps, iliac crest, supraspinal, abdominal, front thigh, medial calf, and quantified using image analysis software. Data was analyzed descriptively (mean±SD, [range]). Coefficient of variation (CV%), intraclass correlation coefficient (ICC, 2.1) and absolute (LoA) and ratio limits of agreement (RLoA) were calculated for day-to-day reliability. Mean sum of SAT thickness was 30.0±19.4 mm [8.0, 80.1 mm], with 3.9±1.8 mm [1.2 mm subscapular, 8.0 mm abdominal] for individual sites. CV for the sum of sites was 4.7%, ICC 0.99, LoA 1.7±3.6 mm, RLoA 0.940 ( * /÷1.155). Measuring SAT with ultrasound has proved to have excellent day-to-day reliability in elite canoe athletes. Recommendations for standardization of the method will further increase accuracy and reproducibility. © Georg Thieme Verlag KG Stuttgart · New York.
Teaching point of care ultrasound skills in medical school: keeping radiology in the driver's seat.
Webb, Emily M; Cotton, James B; Kane, Kevin; Straus, Christopher M; Topp, Kimberly S; Naeger, David M
2014-07-01
Ultrasound is used increasingly in medical practice as a tool for focused bedside diagnosis and technical assistance during procedures. Widespread availability of small portable units has put this technology into the hands of many physicians and medical students who lack dedicated training, leaving the education and introduction of this key modality increasingly to physicians from other specialties. We developed a radiology-led program to teach ultrasound skills to preclinical medical students. To develop this new ultrasound program we 1) established a program leader, 2) developed teaching materials, 3) created a hands-on interactive program, and 4) recruited the necessary instructors. The program was piloted with the first-year medical student class of 154 students. The introductory session was assessed by pre- and post-activity Likert scale-based surveys. Of 154 (68.8%) students, 106 completed a voluntary online survey before starting the program and 145 students (94.2%) completed a voluntary survey after the session. Students found the program educationally valuable (4.64 of 5) and reported that it improved their understanding of ultrasound imaging (4.7 of 5). Students' reported confidence in identifying abdominal organs, intra-abdominal fluid, and Morison pouch that was significantly higher on the postactivity survey compared to the presurvey (P < .001 for all). We piloted a radiology-led program to teach ultrasound skills to preclinical medical students. Students found the experience enjoyable and educationally valuable. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.
Cho, Hee Kyung; Jung, Gil Su; Kim, Eun Hyuk; Cho, Yun Woo; Kim, Sang Woo; Ahn, Sang Ho
2016-01-01
Low back pain is associated with transversus abdominis (TrA) dysfunction. Recently, it was proposed that Neuromuscular Electrical Stimulation (NMES) could be used to stimulate deep abdominal muscle contractions and improve lumbopelvic stability. The purpose of this study was to determine the optimal stimulation frequency required during NMES for the activation of deep abdominal muscles. Twenty healthy volunteers between the ages of 24 and 32 were included. The portable research-stimulator was applied using a 10 second contraction time, and a 10 second resting time at 20 Hz, 50 Hz, and 80 Hz. Changes in muscle thicknesses were determined for the TrA, obliquus internus (OI), and obliquus externus (OE) by real time ultrasound imaging. Significant thickness increases in the TrA, OI, and OE were observed during NMES versus the resting state (p < 0.05). Of the frequencies examined, 50 Hz NMES produced the greatest increase in TrA thickness (1.33 fold as compared with 1.22 fold at 20 Hz and 1.21 fold at 80 Hz) (p < 0.05). Our results indicate that NMES can preferentially stimulate contractions in deep abdominal stabilizing muscles. Most importantly, 50 Hz NMES produced greater muscle thickness increases than 20 or 80 Hz.
Conlon, Thomas W; Himebauch, Adam S; Fitzgerald, Julie C; Chen, Aaron E; Dean, Anthony J; Panebianco, Nova; Darge, Kassa; Cohen, Meryl S; Greeley, William J; Berg, Robert A; Nishisaki, Akira
2015-03-01
To determine the feasibility and describe the process of implementing a pediatric critical care bedside ultrasound program in a large academic PICU and to evaluate the impact of bedside ultrasound on clinical management. Retrospective case series, description of program implementation. Single-center quaternary noncardiac PICU in a children's hospital. Consecutive patients from January 22, 2012, to July 22, 2012, with bedside ultrasounds performed and interpreted by pediatric critical care practitioners. A pediatric critical care bedside ultrasound program consisting of a 2-day immersive course followed by clinical performance with internal quality assurance review was implemented. Studies performed in the PICU following training were documented and reviewed against reference standards including subspecialist-performed ultrasound or clinical response. Seventeen critical care faculties and eight fellows recorded 201 bedside ultrasound studies over 6 months in defined core applications: 57 procedural (28%), 76 hemodynamic (38%), 35 thoracic (17%), and 33 abdominal (16%). A quality assurance review identified 23 studies (16% of all nonprocedural studies) as critical (affected clinical management or gave valuable information). Forty-eight percent of those studies (11/23) were within the hemodynamic core. The proportion of critical studies were not significantly different across the applications (hemodynamic, 11/76 [15%] vs thoracic and abdominal, 12/68 [18%]; p = 0.65). Examples of critical studies include evidence of tamponade secondary to pleural effusions, identification of pulmonary hypertension, hemodynamic assessment before tracheal intubation, recognition of hypovolemia and systemic vascular resistance abnormalities, determination of pneumothorax, location of chest tube and urinary catheter, and differentiation of pleural fluid from pulmonary consolidation. Implementation of a critical care bedside ultrasound program for critical care providers in a large
Emergent ultrasound evaluation of the pediatric female pelvis.
Back, Susan J; Maya, Carolina L; Zewdneh, Daniel; Epelman, Monica
2017-08-01
Ultrasound is the primary imaging modality of the pediatric female pelvis and is often requested to evaluate girls with pelvic or abdominal pain or abnormal bleeding. The US interpretation can help guide the clinician toward medical or surgical management. Here we discuss the normal US anatomy of the female pelvis and illustrate, through case examples, conditions encountered when performing emergent pelvic US for common and uncommon clinical scenarios.
Daly, Jonathan; Gunn, Ian; Kirby, Nick; Jones, Robert; Galloway, David
2007-09-01
Serial ultrasound examination of four mature female sevengill sharks (Notorynchus cepedianus) was carried out over 18 months. Monitoring the reproductive cycle and development of follicles and fetuses in sharks in a noninvasive manner using this technique has not been reported previously. Sharks were caught out of the "Oceanarium" tank by divers using a specially made catch-out bag, and brought to a holding area for examination. A behavior scoring system was used to monitor the impact of regular handling on the well-being of the animals. Ultrasound showed the growth and regression of follicles in sevengill ovaries, and allowed an approximation of the reproductive stage of these sharks. Monitoring behavior at five time points during the procedure showed that regular handling of sharks for clinical studies could be done with minimal impact on animal welfare. The ability to follow reproductive events in elasmobranches using ultrasonography is an important step in the application of assisted reproductive technology in these species. Assisted reproductive technology, such as monitoring female reproductive cycles and artificial insemination, could potentially be used to maintain genetic diversity and compliment aquaria-based breeding programs for endangered species such as the gray nurse shark (Carcharias taurus). Zoo Biol 26:383-395, 2007. (c) 2007 Wiley-Liss, Inc.
H, Neumann; A P, Schulz; S, Breer; A, Unger; B, Kienast
2015-01-01
Osteochondral injuries, if not treated appropriately, often lead to severe osteoarthritis of the affected joint. Without refixation of the osteochondral fragment, human cartilage only repairs these defects imperfectly. All existing refixation systems for chondral defects have disadvantages, for instance bad MRI quality in the postoperative follow-up or low anchoring forces. To address the problem of reduced stability in resorbable implants, ultrasound-activated pins were developed. By ultrasound-activated melting of the tip of these implants a higher anchoring is assumed. Aim of the study was to investigate, if ultrasound-activated pins can provide a secure refixation of osteochondral fractures comparing to conventional screw and conventional, resorbable pin osteosynthesis. CT scans and scanning electron microscopy should proovegood refixation results with no further tissue damage by the melting of the ultrasound-activated pins in comparison to conventional osteosynthesis. Femoral osteochondral fragments in sheep were refixated with ultrasound-activated pins (SonicPin™), Ethipins(®) and screws (Asnis™). The quality of the refixated fragments was examined after three month of full weight bearing by CT scans and scanning electron microscopy of the cartilage surface. The CT examination found almost no statistically significant difference in the quality of refixation between the three different implants used. Concerning the CT morphology, ultrasound-activated pins demonstrated at least the same quality in refixation of osteochondral fragments as conventional resorbable pins or screws. The scanning electron microscopy showed no major surface damage by the three implants, especially any postulated cartilage damage induced by the heat of the ultrasound-activated pin. The screws protruded above the cartilage surface, which may affect the opposingtibial surface. Using CT scans and scanning electron microscopy, the SonicPin™, the Ethipin(®) and screws were at least
Gishti, Olta; Gaillard, Romy; Manniesing, Rashindra; Abrahamse-Berkeveld, Marieke; van der Beek, Eline M; Heppe, Denise H M; Steegers, Eric A P; Hofman, Albert; Duijts, Liesbeth; Durmuş, Büşra; Jaddoe, Vincent W V
2014-07-01
Higher infant growth rates are associated with an increased risk of obesity in later life. We examined the associations of longitudinally measured fetal and infant growth patterns with total and abdominal fat distribution in childhood. We performed a population-based prospective cohort study among 6464 children. We measured growth characteristics in the second and third trimesters of pregnancy, at birth, and at 6, 12, and 24 months. Body mass index, fat mass index (body fat mass/height(2)), lean mass index (body lean mass/height(2)), android/gynoid fat ratio measured by dual-energy x-ray absorptiometry, and sc and preperitoneal abdominal fat measured by ultrasound at the median age of 6.0 years (90% range, 5.7-7.4). We observed that weight gain in the second and third trimesters of fetal life and in early, mid, and late infancy were independently and positively associated with childhood body mass index (P < .05). Only infant weight gain was associated with higher fat mass index, android/gynoid fat ratio, and abdominal fat in childhood (P < .05). Children with both fetal and infant growth acceleration had the highest childhood body mass index, fat mass index, and sc abdominal fat, whereas children with fetal growth deceleration and infant growth acceleration had the highest value for android/gynoid fat ratio and the lowest value for lean mass index (P < .05). Growth in both fetal life and infancy affects childhood body mass index, whereas only infant growth directly affects measured total body and abdominal fat. Fetal growth deceleration followed by infant growth acceleration may lead to an adverse body fat distribution in childhood.
Robotically assisted velocity-sensitive triggered focused ultrasound surgery
NASA Astrophysics Data System (ADS)
Maier, Florian; Brunner, Alexander; Jenne, Jürgen W.; Krafft, Axel J.; Semmler, Wolfhard; Bock, Michael
2012-11-01
Magnetic Resonance (MR) guided Focused Ultrasound Surgery (FUS) of abdominal organs is challenging due to breathing motion and limited patient access in the MR environment. In this work, an experimental robotically assisted FUS setup was combined with a MR-based navigator technique to realize motion-compensated sonications and online temperature imaging. Experiments were carried out in a static phantom, during periodic manual motion of the phantom without triggering, and with triggering to evaluate the triggering method. In contrast to the non-triggered sonication, the results of the triggered sonication show a confined symmetric temperature distribution. In conclusion, the velocity sensitive navigator can be employed for triggered FUS to compensate for periodic motion. Combined with the robotic FUS setup, flexible treatment of abdominal targets might be realized.
Abdominal Pain in the Geriatric Patient.
Magidson, Phillip D; Martinez, Joseph P
2016-08-01
With an aging population, emergency department clinicians can expect an increase in geriatric patients presenting with abdominal pain. Compared with younger patients, this patient population is less likely to present with classic symptoms, physical examination findings, and laboratory values of abdominal disease. However, the morbidity and mortality associated with elderly patients presenting with abdominal pathologic conditions are significant. For this reason, the clinician must be familiar with some subtle and not so subtle differences when caring for the geriatric patient with abdominal pain to ensure timely diagnosis and appropriate treatment. Copyright © 2016 Elsevier Inc. All rights reserved.
Kok, Annette M; Nguyen, V Lai; Speelman, Lambert; Brands, Peter J; Schurink, Geert-Willem H; van de Vosse, Frans N; Lopata, Richard G P
2015-05-01
Abdominal aortic aneurysms (AAAs) are local dilations that can lead to a fatal hemorrhage when ruptured. Wall stress analysis of AAAs is a novel tool that has proven high potential to improve risk stratification. Currently, wall stress analysis of AAAs is based on computed tomography (CT) and magnetic resonance imaging; however, three-dimensional (3D) ultrasound (US) has great advantages over CT and magnetic resonance imaging in terms of costs, speed, and lack of radiation. In this study, the feasibility of 3D US as input for wall stress analysis is investigated. Second, 3D US-based wall stress analysis was compared with CT-based results. The 3D US and CT data were acquired in 12 patients (diameter, 35-90 mm). US data were segmented manually and compared with automatically acquired CT geometries by calculating the similarity index and Hausdorff distance. Wall stresses were simulated at P = 140 mm Hg and compared between both modalities. The similarity index of US vs CT was 0.75 to 0.91 (n = 12), with a median Hausdorff distance ranging from 4.8 to 13.9 mm, with the higher values found at the proximal and distal sides of the AAA. Wall stresses were in accordance with literature, and a good agreement was found between US- and CT-based median stresses and interquartile stresses, which was confirmed by Bland-Altman and regression analysis (n = 8). Wall stresses based on US were typically higher (+23%), caused by geometric irregularities due to the registration of several 3D volumes and manual segmentation. In future work, an automated US registration and segmentation approach is the essential point of improvement before pursuing large-scale patient studies. This study is a first step toward US-based wall stress analysis, which would be the modality of choice to monitor wall stress development over time because no ionizing radiation and contrast material are involved. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Role of ultrasound in colorectal diseases.
Bor, Renáta; Fábián, Anna; Szepes, Zoltán
2016-11-21
Ultrasound is an undervalued non-invasive examination in the diagnosis of colonic diseases. It has been replaced by the considerably more expensive magnetic resonance imaging and computed tomography, despite the fact that, as first examination, it can usefully supplement the diagnostic process. Transabdominal ultrasound can provide quick information about bowel status and help in the choice of adequate further examinations and treatment. Ultrasonography, as a screening imaging modality in asymptomatic patients can identify several colonic diseases such as diverticulosis, inflammatory bowel disease or cancer. In addition, it is widely available, cheap, non-invasive technique without the use of ionizing radiation, therefore it is safe to use in childhood or during pregnancy, and can be repeated at any time. New ultrasound techniques such as elastography, contrast enhanced and Doppler ultrasound, mini-probes rectal and transperineal ultrasonography have broadened the indication. It gives an overview of the methodology of various ultrasound examinations, presents the morphology of normal bowel wall and the typical changes in different colonic diseases. We will pay particular attention to rectal and transperineal ultrasound because of their outstanding significance in the diagnosis of rectal and perineal disorders. This article seeks to overview the diagnostic impact and correct indications of bowel ultrasound.
Koop, Herbert; Koprdova, Simona; Schürmann, Christine
2016-01-29
Chronic abdominal wall pain is a poorly recognized clinical problem despite being an important element in the differential diagnosis of abdominal pain. This review is based on pertinent articles that were retrieved by a selective search in PubMed and EMBASE employing the terms "abdominal wall pain" and "cutaneous nerve entrapment syndrome," as well as on the authors' clinical experience. In 2% to 3% of patients with chronic abdominal pain, the pain arises from the abdominal wall; in patients with previously diagnosed chronic abdominal pain who have no demonstrable pathological abnormality, this likelihood can rise as high as 30% . There have only been a small number of clinical trials of treatment for this condition. The diagnosis is made on clinical grounds, with the aid of Carnett's test. The characteristic clinical feature is strictly localized pain in the anterior abdominal wall, which is often mischaracterized as a "functional" complaint. In one study, injection of local anesthesia combined with steroids into the painful area was found to relieve pain for 4 weeks in 95% of patients. The injection of lidocaine alone brought about improvement in 83-91% of patients. Long-term pain relief ensued after a single lidocaine injection in 20-30% of patients, after repeated injections in 40-50% , and after combined lidocaine and steroid injections in up to 80% . Pain that persists despite these treatments can be treated with surgery (neurectomy). Chronic abdominal wall pain is easily diagnosed on physical examination and can often be rapidly treated. Any physician treating patients with abdominal pain should be aware of this condition. Further comparative treatment trials will be needed before a validated treatment algorithm can be established.
Chang, Li-Wen; Hou, Mei-Ling; Hung, Shuo-Hui; Lin, Lie-Chwen; Tsai, Tung-Hu
2015-01-01
Bubble formulations have both diagnostic and therapeutic applications. However, research on nanobubbles/nanodroplets remains in the initial stages. In this study, a nanodroplet formulation was prepared and loaded with a novel class of chemotherapeutic drug, ie, quercetin, to observe its pharmacokinetic properties and ultrasonic bioimaging of specific sites, namely the abdominal vein and bladder. Four parallel groups were designed to investigate the effects of ultrasound and nanodroplets on the pharmacokinetics of quercetin. These groups were quercetin alone, quercetin triggered with ultrasound, quercetin-encapsulated in nanodroplets, and quercetin encapsulated in nanodroplets triggered with ultrasound. Spherical vesicles with a mean diameter of 280 nm were formed, and quercetin was completely encapsulated within. In vivo ultrasonic imaging confirmed that the nanodroplets could be treated by ultrasound. The results indicate that the initial 5-minute serum concentration, area under the concentration–time curve, elimination half-life, and clearance of quercetin were significantly enhanced by nanodroplets with or without ultrasound. PMID:25945049
Pulanic, Tajana Klepac; Venkatesan, Aradhana M.; Segars, James; Sokka, Sham; Wood, Bradford J.; Stratton, Pamela
2015-01-01
In order to ensure safe magnetic resonance-guided high-intensity focused ultrasound ablation of uterine leiomyomas, ultrasound beam path should be free of intervening scar and bowel. Pre-treatment magnetic resonance imaging of a 9cm long and 7.7cm wide leiomyomatous uterus in a 39-year-old woman with menorrhagia and abdominopelvic pain initially demonstrated a focused ultrasound treatment path without bowel between the uterus and abdominal wall. On the day of ablation, however, multiple loops of bowel were observed in the ultrasound beam path by magnetic resonance imaging. Uterine repositioning was accomplished with a 76 mm donut vaginal pessary which anteverted the fundus and successfully displaced bowel. A vaginal pessary may aid in repositioning an axial or retroverted uterus to enable ablation of uterine leiomyomas. PMID:26584482
Klepac Pulanic, Tajana; Venkatesan, Aradhana M; Segars, James; Sokka, Sham; Wood, Bradford J; Stratton, Pamela
2016-01-01
In order to ensure safe magnetic resonance-guided, high-intensity focused, ultrasound ablation of uterine leiomyomas, the ultrasound beam path should be free of intervening scar and bowel. Pre-treatment MRI of a 9-cm long and 7.7-cm wide leiomyomatous uterus in a 39-year-old woman with menorrhagia and abdominopelvic pain initially demonstrated a focused ultrasound treatment path without a bowel between the uterus and the abdominal wall. On the day of ablation, however, multiple loops of bowel were observed in the ultrasound beam path by MRI. Uterine repositioning was accomplished with a 76-mm donut vaginal pessary, which anteverted the fundus and successfully displaced the bowel. A vaginal pessary may aid in repositioning an axial or retroverted uterus to enable ablation of uterine leiomyomas. © 2015 S. Karger AG, Basel.
Jeong, Seung Uk; Aizan, Hassanuddin; Song, Tae Jun; Seo, Dong Wan; Kim, Su-Hui; Park, Do Hyun; Lee, Sang Soo; Lee, Sung Koo; Kim, Myung-Hwan
2013-01-01
AIM: To evaluate the feasibility of diagnostic and therapeutic transgastric (TG) peritoneoscopic interventions with a forward-viewing endoscopic ultrasound (FV-EUS). METHODS: This prospective endoscopic experimental study used an animal model. Combined TG peritoneoscopic interventions and EUS examination of the intra-abdominal organs were performed using an FV-EUS on 10 animal models (1 porcine and 9 canine). The procedures carried out include EUS evaluation and endoscopic biopsy of intraperitoneal organs, EUS-guided fine needle aspiration (EUS-FNA), EUS-guided radiofrequency ablation (EUS-RFA), and argon plasma coagulation (APC) for hemostatic control. The animals were kept alive for 7 d, and then necropsy was performed to evaluate results and complications. RESULTS: In all 10 animals, TG peritoneoscopy, followed by endoscopic biopsy for the liver, spleen, abdominal wall, and omentum, was performed successfully. APC helped control minor bleeding. Visualization of intra-abdominal solid organs with real-time EUS was accomplished with ease. Intraperitoneal EUS-FNA was successfully performed on the liver, spleen, and kidney. Similarly, a successful outcome was achieved with EUS-RFA of the hepatic parenchyma. No adverse events were recorded during the study. CONCLUSION: Peritoneoscopic natural orifice transluminal endoscopic surgery (NOTES) interventions through FV-EUS were feasible in providing evaluation and performing endoscopic procedures. It promises potential as a platform for future EUS-based NOTES. PMID:24222961
Musculoskeletal ultrasound in rheumatology in Korea: targeted ultrasound initiative survey.
Kang, Taeyoung; Wakefield, Richard J; Emery, Paul
2016-04-01
In collaboration with the Targeted Ultrasound Initiative (TUI), to conduct the first study in Korea to investigate current practices in ultrasound use among Korean rheumatologists. We translated the TUI Global Survey into Korean and added questions to better understand the specific challenges facing rheumatologists in Korea. To target as many rheumatologists in Korea as possible, we created an on-line version of this survey, which was conducted from March to April 2013. Rheumatologists are in charge of ultrasound in many Korean hospitals. Rheumatologists in hospitals and private clinics use ultrasound to examine between one and five patients daily; they use ultrasound for diagnosis more than monitoring and receive compensation of about US$30-50 per patient. There are marked differences in the rates of ultrasound usage between rheumatologists who work in private practice compared with tertiary hospitals. Korean rheumatologists not currently using ultrasound in their practice appear eager to do so. This survey provides important insights into the current status of ultrasound in rheumatology in Korea and highlights several priorities; specifically, greater provision of formal training, standardization of reporting and accrual of greater experience among ultrasound users. If these needs are addressed, all rheumatology departments in Korea are likely to use ultrasound or have access to it in the future. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.
Yoda, Kazushige; Umeda, Tokuo; Hasegawa, Tomoyuki
2003-11-01
Organ movements that occur naturally as a result of vital functions such as respiration and heartbeat cause deterioration of image quality in nuclear medicine imaging. Among these movements, respiration has a large effect, but there has been no practical method of correcting for this. In the present study, we examined a method of correction that uses ultrasound images to correct baseline shifts caused by respiration in cardiac nuclear medicine examinations. To evaluate the validity of this method, simulation studies were conducted with an X-ray TV machine instead of a nuclear medicine scanner. The X-ray TV images and ultrasound images were recorded as digital movies and processed with public domain software (Scion Image). Organ movements were detected in the ultrasound images of the subcostal four-chamber view mode using slit regions of interest and were measured on a two-dimensional image coordinate. Then translational shifts were applied to the X-ray TV images to correct these movements by using macro-functions of the software. As a result, respiratory movements of about 20.1 mm were successfully reduced to less than 2.6 mm. We conclude that this correction technique is potentially useful in nuclear medicine cardiology.
Dalen, Havard; Gundersen, Guri H; Skjetne, Kyrre; Haug, Hilde H; Kleinau, Jens O; Norekval, Tone M; Graven, Torbjorn
2015-08-01
Routine assessment of volume state by ultrasound may improve follow-up of heart failure patients. We aimed to study the feasibility and reliability of focused pocket-size ultrasound examinations of the pleural cavities and the inferior vena cava performed by nurses to assess volume state at an outpatient heart failure clinic. Ultrasound examinations were performed in 62 included heart failure patients by specialized nurses with a pocket-size imaging device (PSID). Patients were then re-examined by a cardiologist with a high-end scanner for reference within 1 h. Specialized nurses were able to obtain and interpret images from both pleural cavities and the inferior vena cava and estimate the volume status in all patients. Time consumption for focused ultrasound examination was median 5 min. In total 26 patients had any kind of pleural effusion (in 39 pleural cavities) by reference. The sensitivity, specificity, positive and negative predictive values were high, all ≥ 92%. The correlations with reference were high for all measurements, all r ≥ 0.79. Coefficients of variation for end-expiratory dimension of inferior vena cava and quantification of pleural effusion were 10.8% and 12.7%, respectively. Specialized nurses were, after a dedicated training protocol, able to obtain reliable recordings of both pleural cavities and the inferior vena cava by PSID and interpret the images in a reliable way. Implementing focused ultrasound examinations to assess volume status by nurses in an outpatient heart failure clinic may improve diagnostics, and thus improve therapy. © The European Society of Cardiology 2014.
Brooks, Cristy; Siegler, Jason C; Marshall, Paul W M
2016-08-02
Although previous research suggests a relationship between chronic low back pain (cLBP) and adiposity, this relationship is poorly understood. No research has explored the relationship between abdominal-specific subcutaneous and visceral adiposity with pain and disability in cLBP individuals. The aim of this study therefore was to examine the relationship of regional and total body adiposity to pain and disability in cLBP individuals. A preliminary explorative study design of seventy (n = 70) adult men and women with cLBP was employed. Anthropometric and adiposity measures were collected, including body mass index, waist-to-hip ratio, total body adiposity and specific ultrasound-based abdominal adiposity measurements. Self-reported pain and disability were measured using a Visual Analogue Scale (VAS) and the Oswestry Disability Index (ODI) questionnaires respectively. Relationships between anthropometric and adiposity measures with pain and disability were assessed using correlation and regression analyses. Significant correlations between abdominal to lumbar adiposity ratio (A-L) variables and the waist-to-hip ratio with self-reported pain were observed. A-L variables were found to predict pain, with 9.1-30.5 % of the variance in pain across the three analysis models explained by these variables. No relationships between anthropometric or adiposity variables to self-reported disability were identified. The findings of this study indicated that regional distribution of adiposity via the A-L is associated with cLBP, providing a rationale for future research on adiposity and cLBP.
Tefas, Cristian; Tanţău, Marcel; Szenftleben, Alexandru; Chiorean, Liliana; Badea, Radu
2015-12-01
Adenomas are frequently encountered in the lower digestive tract but are rarely diagnosed in the biliary tree. We report a case of villous adenoma of the common hepatic duct. A 58-year old male was admitted with a four week history of intermittent upper right quadrant pain. Gray scale and contrast-enhanced abdominal ultrasound showed a mass inside the common hepatic duct with arterial enhancement and slow wash-out during the late venous phase. Subsequent endoscopic retrograde cholangiopancreatography and intraductal ultrasound confirmed the presence of the lesion. The final histopathological examination showed villous adenoma of the common hepatic duct with high-grade dysplasia. Contrast enhanced ultrasonography used in conjecture with endoscopic retrograde cholangiopancreatography can help in differentiating biliary tumors.
H, Neumann; A.P, Schulz; S, Breer; A, Unger; B, Kienast
2015-01-01
Background: Osteochondral injuries, if not treated appropriately, often lead to severe osteoarthritis of the affected joint. Without refixation of the osteochondral fragment, human cartilage only repairs these defects imperfectly. All existing refixation systems for chondral defects have disadvantages, for instance bad MRI quality in the postoperative follow-up or low anchoring forces. To address the problem of reduced stability in resorbable implants, ultrasound-activated pins were developed. By ultrasound-activated melting of the tip of these implants a higher anchoring is assumed. Aim of the study was to investigate, if ultrasound-activated pins can provide a secure refixation of osteochondral fractures comparing to conventional screw and conventional, resorbable pin osteosynthesis. CT scans and scanning electron microscopy should proovegood refixation results with no further tissue damage by the melting of the ultrasound-activated pins in comparison to conventional osteosynthesis. Methods: Femoral osteochondral fragments in sheep were refixated with ultrasound-activated pins (SonicPin™), Ethipins® and screws (Asnis™). The quality of the refixated fragments was examined after three month of full weight bearing by CT scans and scanning electron microscopy of the cartilage surface. Results: The CT examination found almost no statistically significant difference in the quality of refixation between the three different implants used. Concerning the CT morphology, ultrasound-activated pins demonstrated at least the same quality in refixation of osteochondral fragments as conventional resorbable pins or screws. The scanning electron microscopy showed no major surface damage by the three implants, especially any postulated cartilage damage induced by the heat of the ultrasound-activated pin. The screws protruded above the cartilage surface, which may affect the opposingtibial surface. Conclusion: Using CT scans and scanning electron microscopy, the Sonic
Hadamard-Encoded Multipulses for Contrast-Enhanced Ultrasound Imaging.
Gong, Ping; Song, Pengfei; Chen, Shigao
2017-11-01
The development of contrast-enhanced ultrasound (CEUS) imaging offers great opportunities for new ultrasound clinical applications such as myocardial perfusion imaging and abdominal lesion characterization. In CEUS imaging, the contrast agents (i.e., microbubbles) are utilized to improve the contrast between blood and tissue based on their high nonlinearity under low ultrasound pressure. In this paper, we propose a new CEUS pulse sequence by combining Hadamard-encoded multipulses (HEM) with fundamental frequency bandpass filter (i.e., filter centered on transmit frequency). HEM consecutively emits multipulses encoded by a second-order Hadamard matrix in each of the two transmission events (i.e., pulse-echo events), as opposed to conventional CEUS methods which emit individual pulses in two separate transmission events (i.e., pulse inversion (PI), amplitude modulation (AM), and PIAM). In HEM imaging, the microbubble responses can be improved by the longer transmit pulse, and the tissue harmonics can be suppressed by the fundamental frequency filter, leading to significantly improved contrast-to-tissue ratio (CTR) and signal-to-noise ratio (SNR). In addition, the fast polarity change between consecutive coded pulse emissions excites strong nonlinear microbubble echoes, further enhancing the CEUS image quality. The spatial resolution of HEM image is compromised as compared to other microbubble imaging methods due to the longer transmit pulses and the lower imaging frequency (i.e., fundamental frequency). However, the resolution loss was shown to be negligible and could be offset by the significantly enhanced CTR, SNR, and penetration depth. These properties of HEM can potentially facilitate robust CEUS imaging for many clinical applications, especially for deep abdominal organs and heart.
Abdominal emergencies in pediatrics.
Coca Robinot, D; Liébana de Rojas, C; Aguirre Pascual, E
2016-05-01
Abdominal symptoms are among the most common reasons for pediatric emergency department visits, and abdominal pain is the most frequently reported symptom. Thorough history taking and physical examination can often reach the correct diagnosis. Knowing the abdominal conditions that are most common in each age group can help radiologists narrow the differential diagnosis. When imaging tests are indicated, ultrasonography is usually the first-line technique, enabling the diagnosis or adding relevant information with the well-known advantages of this technique. Nowadays, plain-film X-ray studies are reserved for cases in which perforation, bowel obstruction, or foreign body ingestion is suspected. It is also important to remember that abdominal pain can also occur secondary to basal pneumonia. CT is reserved for specific indications and in individual cases, for example, in patients with high clinical suspicion of abdominal disease and inconclusive findings at ultrasonography. We review some of the most common conditions in pediatric emergencies, the different imaging tests indicated in each case, and the imaging signs in each condition. Copyright © 2016 SERAM. Published by Elsevier España, S.L.U. All rights reserved.
Figueiredo, Vânia F; Amorim, Juleimar S C; Pereira, Aline M; Ferreira, Paulo H; Pereira, Leani S M
2015-01-01
Low back pain (LBP) and urinary incontinence (UI) are highly prevalent among elderly individuals. In young adults, changes in trunk muscle recruitment, as assessed via ultrasound imaging, may be associated with lumbar spine stability. To assess the associations between LBP, UI, and the pattern of transversus abdominis (TrA), internal (IO), and external oblique (EO) muscle recruitment in the elderly as evaluated by ultrasound imaging. Fifty-four elderly individuals (mean age: 72±5.2 years) who complained of LBP and/or UI as assessed by the McGill Pain Questionnaire, Incontinence Questionnaire-Short Form, and ultrasound imaging were included in the study. The statistical analysis comprised a multiple linear regression model, and a p-value <0.05 was considered significant. The regression models for the TrA, IO, and EO muscle thickness levels explained 2.0% (R2=0.02; F=0.47; p=0.628), 10.6% (R2=0.106; F=3.03; p=0.057), and 10.1% (R2=0.101; F=2.70; p=0.077) of the variability, respectively. None of the regression models developed for the abdominal muscles exhibited statistical significance. A significant and negative association (p=0.018; β=-0.0343) was observed only between UI and IO recruitment. These results suggest that age-related factors may have interfered with the findings of the study, thus emphasizing the need to perform ultrasound imaging-based studies to measure abdominal muscle recruitment in the elderly.
Ultrasound Fracture Diagnosis in Space
NASA Technical Reports Server (NTRS)
Dulchavsky, Scott A.; Amponsah, David; Sargsyan, Ashot E.; Garcia, Kathleen M.; Hamilton, Douglas R.; vanHolsbeeck, Marnix
2010-01-01
Introduction: This ground-based investigation accumulated high-level clinical evidence on the sensitivity and specificity of point of care ultrasound performed by expert and novice users for the rapid diagnosis of musculoskeletal (MSK) injuries. We developed preliminary educational methodologies to provide just-in-time training of novice users by creating multi-media training tools and imaging procedures for non expert operators and evaluated the sensitivity and specificity of non-expert performed musculoskeletal ultrasound to diagnose acute injuries in a Level 1 Trauma Center. Methods: Patients with potential MSK injuries were identified in the emergency room. A focused MSK ultrasound was performed by expert operators and compared to standard radiographs. A repeat examination was performed by non-expert operators who received a short, just-in-time multimedia education aid. The sensitivity and specificity of the expert and novice ultrasound examinations were compared to gold standard radiography. Results: Over 800 patients were enrolled in this study. The sensitivity and specificity of expert performed ultrasound exceeded 98% for MSK injuries. Novice operators achieved 97% sensitivity and 99% specificity for targeted examinations with the greatest error in fractures involving the hand and foot. Conclusion: Point of care ultrasound is a sensitive and specific diagnostic test for MSK injury when performed by experts and just-in-time trained novice operators.
A new fringeline-tracking approach for color Doppler ultrasound imaging phase unwrapping
NASA Astrophysics Data System (ADS)
Saad, Ashraf A.; Shapiro, Linda G.
2008-03-01
Color Doppler ultrasound imaging is a powerful non-invasive diagnostic tool for many clinical applications that involve examining the anatomy and hemodynamics of human blood vessels. These clinical applications include cardio-vascular diseases, obstetrics, and abdominal diseases. Since its commercial introduction in the early eighties, color Doppler ultrasound imaging has been used mainly as a qualitative tool with very little attempts to quantify its images. Many imaging artifacts hinder the quantification of the color Doppler images, the most important of which is the aliasing artifact that distorts the blood flow velocities measured by the color Doppler technique. In this work we will address the color Doppler aliasing problem and present a recovery methodology for the true flow velocities from the aliased ones. The problem is formulated as a 2D phase-unwrapping problem, which is a well-defined problem with solid theoretical foundations for other imaging domains, including synthetic aperture radar and magnetic resonance imaging. This paper documents the need for a phase unwrapping algorithm for use in color Doppler ultrasound image analysis. It describes a new phase-unwrapping algorithm that relies on the recently developed cutline detection approaches. The algorithm is novel in its use of heuristic information provided by the ultrasound imaging modality to guide the phase unwrapping process. Experiments have been performed on both in-vitro flow-phantom data and in-vivo human blood flow data. Both data types were acquired under a controlled acquisition protocol developed to minimize the distortion of the color Doppler data and hence to simplify the phase-unwrapping task. In addition to the qualitative assessment of the results, a quantitative assessment approach was developed to measure the success of the results. The results of our new algorithm have been compared on ultrasound data to those from other well-known algorithms, and it outperforms all of them.
Virtual Guidance Ultrasound: A Tool to Obtain Diagnostic Ultrasound for Remote Environments
NASA Technical Reports Server (NTRS)
Caine,Timothy L.; Martin David S.; Matz, Timothy; Lee, Stuart M. C.; Stenger, Michael B.; Platts, Steven H.
2012-01-01
Astronauts currently acquire ultrasound images on the International Space Station with the assistance of real-time remote guidance from an ultrasound expert in Mission Control. Remote guidance will not be feasible when significant communication delays exist during exploration missions beyond low-Earth orbit. For example, there may be as much as a 20- minute delay in communications between the Earth and Mars. Virtual-guidance, a pre-recorded audio-visual tutorial viewed in real-time, is a viable modality for minimally trained scanners to obtain diagnostically-adequate images of clinically relevant anatomical structures in an autonomous manner. METHODS: Inexperienced ultrasound operators were recruited to perform carotid artery (n = 10) and ophthalmic (n = 9) ultrasound examinations using virtual guidance as their only instructional tool. In the carotid group, each each untrained operator acquired two-dimensional, pulsed, and color Doppler of the carotid artery. In the ophthalmic group, operators acquired representative images of the anterior chamber of the eye, retina, optic nerve, and nerve sheath. Ultrasound image quality was evaluated by independent imaging experts. RESULTS: Eight of the 10 carotid studies were judged to be diagnostically adequate. With one exception the quality of all the ophthalmic images were adequate to excellent. CONCLUSION: Diagnostically-adequate carotid and ophthalmic ultrasound examinations can be obtained by untrained operators with instruction only from an audio/video tutorial viewed in real time while scanning. This form of quick-response-guidance, can be developed for other ultrasound examinations, represents an opportunity to acquire important medical and scientific information for NASA flight surgeons and researchers when trained medical personnel are not present. Further, virtual guidance will allow untrained personnel to autonomously obtain important medical information in remote locations on Earth where communication is
... Clearinghouse What are abdominal adhesions? Abdominal adhesions are bands of fibrous tissue that can form between abdominal ... Esophagus Stomach Large intestine Adhesion Abdominal adhesions are bands of fibrous tissue that can form between abdominal ...
... and Recurrent or Functional Abdominal Pain (RAP or FAP) What is abdominal pain? Abdominal pain , or stomachache, ... recurrent abdominal pain (RAP) or functional abdominal pain (FAP)? If your health care provider has ruled out ...
2006-01-01
Executive Summary Objective The aim of this review was to assess the clinical utility of portable bladder ultrasound. Clinical Need: Target Population and Condition Data from the National Population Health Survey indicate prevalence rates of urinary incontinence are 2.5% in women and 1.4 % in men in the general population. Prevalence of urinary incontinence is higher in women than men and prevalence increases with age. Identified risk factors for urinary incontinence include female gender, increasing age, urinary tract infections (UTI), poor mobility, dementia, smoking, obesity, consuming alcohol and caffeine beverages, physical activity, pregnancy, childbirth, forceps and vacuum-assisted births, episiotomy, abdominal resection for colorectal cancer, and hormone replacement therapy. For the purposes of this review, incontinence populations will be stratified into the following; the elderly, urology patients, postoperative patients, rehabilitation settings, and neurogenic bladder populations. Urinary incontinence is defined as any involuntary leakage of urine. Incontinence can be classified into diagnostic clinical types that are useful in planning evaluation and treatment. The major types of incontinence are stress (physical exertion), urge (overactive bladder), mixed (combined urge and stress urinary incontinence), reflex (neurological impairment of the central nervous system), overflow (leakage due to full bladder), continuous (urinary tract abnormalities), congenital incontinence, and transient incontinence (temporary incontinence). Postvoid residual (PVR) urine volume, which is the amount of urine in the bladder immediately after urination, represents an important component in continence assessment and bladder management to provide quantitative feedback to the patient and continence care team regarding the effectiveness of the voiding technique. Although there is no standardized definition of normal PVR urine volume, measurements greater than 100 mL to 150 m
Arora, Samantha; Cheung, Angela C; Tarique, Usman; Agarwal, Arnav; Firdouse, Mohammed; Ailon, Jonathan
2017-09-01
To compare point-of-care ultrasound and physical examination (PEx), each performed by first-year medical students after brief teaching, for assessing ascites and hepatomegaly. Ultrasound and PEx were compared on: (1) reliability, validity and performance, (2) diagnostic confidence, ease of use, utility, and applicability. A single-center, randomized controlled trial was performed at a tertiary centre. First-year medical students were randomized to use ultrasound or PEx to assess for ascites and hepatomegaly. Cohen's kappa and interclass coefficient (ICC) were used to measure interrater reliability between trainee assessments and the reference standard (a same day ultrasound by a radiologist). Sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) were compared. A ten-point Likert scale was used to assess trainee diagnostic confidence and perceptions of utility. There were no significant differences in interobserver reliability, sensitivity, specificity, accuracy, PPV, or NPV between the ultrasound and PEx groups. However, students in the ultrasound group provided higher scores for perceived utility (ascites 8.38 ± 1.35 vs 7.08 ± 1.86, p = 0.008; hepatomegaly 7.68 ± 1.52 vs 5.36 ± 2.48, p < 0.001) and likelihood of adoption (ascites 8.67 ± 1.61 vs 7.46 ± 1.79, p = 0.02; hepatomegaly 8.12 ± 1.90 vs 5.92 ± 2.32, p = 0.001). When performed by first-year medical students, the validity and reliability of ultrasound is comparable to PEx, but with greater perceived utility and likelihood of adoption. With similarly brief instruction, point-of-care ultrasonography can be as effectively learned and performed as PEx, with a high degree of interest from trainees.
Larsson, Joel; Båth, Magnus; Ledenius, Kerstin; Caisander, Håkan; Thilander-Klang, Anne
2016-06-01
The purpose of this study was to investigate the effect of different combinations of convolution kernel and the level of Adaptive Statistical iterative Reconstruction (ASiR™) on diagnostic image quality as well as visualisation of anatomical structures in paediatric abdominal computed tomography (CT) examinations. Thirty-five paediatric patients with abdominal pain with non-specified pathology undergoing abdominal CT were included in the study. Transaxial stacks of 5-mm-thick images were retrospectively reconstructed at various ASiR levels, in combination with three convolution kernels. Four paediatric radiologists rated the diagnostic image quality and the delineation of six anatomical structures in a blinded randomised visual grading study. Image quality at a given ASiR level was found to be dependent on the kernel, and a more edge-enhancing kernel benefitted from a higher ASiR level. An ASiR level of 70 % together with the Soft™ or Standard™ kernel was suggested to be the optimal combination for paediatric abdominal CT examinations. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Stoner, Lee; Geoffron, Morgane; Cornwall, Jon; Chinn, Victoria; Gram, Martin; Credeur, Daniel; Fryer, Simon
2016-12-01
Recently, it was reported that intra-abdominal thickness (IAT) assessments using ultrasound are most reliable if measured from the linea alba to the anterior vertebral column. These 2 anatomical sites can be simultaneously visualized using a linear array transducer. Linear array transducers have different operational characteristics when compared with conventional curved array transducers and are more reliable for some ultrasound-derived measures such as abdominal subcutaneous fat thickness. However, it is unknown whether linear array transducers facilitate more reliable IAT measurements than curved array transducers. The purpose of the current study was to (1) compare the reliability of linear and curved array transducer assessments of IAT and maximal abdominal ratio (MAR) and (2) use the findings to update central adiposity measurement guidelines. Fifteen healthy adults (mean [SD], 27 [10] years; 60% female) with a range of somatotypes (body mass index: mean [SD], 24 [4]; range, 19-33 kg/m; waist circumference: mean [SD], 75 [11]; range, 61-96 cm) were tested on 3 mornings under standardized conditions. Intra-abdominal thickness was assessed 2 cm above the umbilicus (transverse plane), measuring from linea alba to the anterior vertebral column. Maximal abdominal ratio was defined as the ratio of IAT to abdominal subcutaneous fat thickness. The IAT range was 25 to 87 mm, and the MAR range was 0.15 to 0.77. Between-day intraclass correlation coefficient values for IAT measurements made were comparable (0.96-0.97) for both transducers, as were MAR values (0.95). In conclusion, while both transducers provided equally reliable measurement of IAT, the use of a single linear array transducer simplifies the assessment of central adiposity.
Nightingale, Kathryn R; Church, Charles C; Harris, Gerald; Wear, Keith A; Bailey, Michael R; Carson, Paul L; Jiang, Hui; Sandstrom, Kurt L; Szabo, Thomas L; Ziskin, Marvin C
2015-07-01
The mechanical index (MI) has been used by the US Food and Drug Administration (FDA) since 1992 for regulatory decisions regarding the acoustic output of diagnostic ultrasound equipment. Its formula is based on predictions of acoustic cavitation under specific conditions. Since its implementation over 2 decades ago, new imaging modes have been developed that employ unique beam sequences exploiting higher-order acoustic phenomena, and, concurrently, studies of the bioeffects of ultrasound under a range of imaging scenarios have been conducted. In 2012, the American Institute of Ultrasound in Medicine Technical Standards Committee convened a working group of its Output Standards Subcommittee to examine and report on the potential risks and benefits of the use of conditionally increased acoustic pressures (CIP) under specific diagnostic imaging scenarios. The term "conditionally" is included to indicate that CIP would be considered on a per-patient basis for the duration required to obtain the necessary diagnostic information. This document is a result of that effort. In summary, a fundamental assumption in the MI calculation is the presence of a preexisting gas body. For tissues not known to contain preexisting gas bodies, based on theoretical predications and experimentally reported cavitation thresholds, we find this assumption to be invalid. We thus conclude that exceeding the recommended maximum MI level given in the FDA guidance could be warranted without concern for increased risk of cavitation in these tissues. However, there is limited literature assessing the potential clinical benefit of exceeding the MI guidelines in these tissues. The report proposes a 3-tiered approach for CIP that follows the model for employing elevated output in magnetic resonance imaging and concludes with summary recommendations to facilitate Institutional Review Board (IRB)-monitored clinical studies investigating CIP in specific tissues. © 2015 by the American Institute of
Bah, Ismaël; Goudie, Eric; Khereba, Mohamed; Ferraro, Pasquale; Duranceau, André; Martin, Jocelyne; Thiffault, Vicky; Liberman, Moishe
2014-05-01
Preoperative evaluation of patients with suspected or confirmed lung cancer consists of clinical and radiological staging. Malignant pleural effusion is a poor prognosticator in non-small-cell lung cancer. Pleural ultrasound (PU) allows for the assessment of pleural effusion, providing real-time guidance for its aspiration and cytological analysis. Pleural Ultrasonography in Lung Cancer (PULC) as an adjunct to physical examination has the potential to improve preoperative staging of non-small-cell lung cancer during first surgical encounter by allowing the evaluation of previously unassessed pleural effusion. This study consisted of a prospective trial of surgeon-performed PU in the preoperative evaluation of lung cancer patients. All patients evaluated in the thoracic surgery clinic with the new or presumed diagnosis of lung cancer were eligible. A portable ultrasound machine was used to evaluate pleural fluid in the bilateral costophrenic sulci with pleural fluid aspiration for cytological analysis. Forty-five patients were prospectively enrolled over a 3-month period. Thirteen patients had ultrasound evidence of a pleural effusion, of which 3 were significant enough for aspiration. Cytological analysis of these effusions yielded malignant cells in 1 patient. Positive PULC evaluation led to a change in clinical staging (M0 to M1a) in 10 patients and a change in pathological staging (pleural fluid cytology positive) in 1 patient. The time required for PULC examination was 15 ± 7 min. There were no complications related to the procedures. Preoperative pleural ultrasonography is a rapid and effective way to improve precision of staging in patients with lung cancer. More precise staging may allow for more appropriate testing, patient prognostication and operative planning.
Ultrasound for internal medicine physicians: the future of the physical examination.
Dulohery, Megan M; Stoven, Samantha; Kurklinsky, Andrew K; Kurklinksy, Andrew; Halvorsen, Andrew; McDonald, Furman S; Bhagra, Anjali
2014-06-01
With the advent of compact ultrasound (US) devices, it is easier for physicians to enhance their physical examinations through the use of US. However, although this new tool is widely available, few internal medicine physicians have US training. This study sought to understand physicians' baseline knowledge and skill, provide education in US principles, and demonstrate that proper use of compact US devices is a skill that can be quickly learned. Training was performed at the Mayo Clinic in June 2010 and June 2011. The participants consisted of internal medicine residents. The workshop included didactics and hands-on US experiences with human and cadaver models in a simulation center. Pretests and posttests of residents' knowledge, attitudes, and skills with US were completed. We reassessed the 2010 group in the spring of 2012 with a long-term retention survey for knowledge and confidence in viewing images. A total of 136 interns completed the workshop. Thirty-nine residents completed the long-term retention survey. Posttest assessments showed a statistically significant improvement in the knowledge of US imaging, confidence in identifying structures, image identification, and image acquisition (P < .0001). In the long-term retention study, knowledge of US imaging and confidence in identifying structures did decline. This educational intervention resulted in improvement in US knowledge and image acquisition. However, the knowledge diminished over time, suggesting that further education is needed if US is to become an important component of internal medicine training and practice. © 2014 by the American Institute of Ultrasound in Medicine.
Model-based ultrasound temperature visualization during and following HIFU exposure.
Ye, Guoliang; Smith, Penny Probert; Noble, J Alison
2010-02-01
This paper describes the application of signal processing techniques to improve the robustness of ultrasound feedback for displaying changes in temperature distribution in treatment using high-intensity focused ultrasound (HIFU), especially at the low signal-to-noise ratios that might be expected in in vivo abdominal treatment. Temperature estimation is based on the local displacements in ultrasound images taken during HIFU treatment, and a method to improve robustness to outliers is introduced. The main contribution of the paper is in the application of a Kalman filter, a statistical signal processing technique, which uses a simple analytical temperature model of heat dispersion to improve the temperature estimation from the ultrasound measurements during and after HIFU exposure. To reduce the sensitivity of the method to previous assumptions on the material homogeneity and signal-to-noise ratio, an adaptive form is introduced. The method is illustrated using data from HIFU exposure of ex vivo bovine liver. A particular advantage of the stability it introduces is that the temperature can be visualized not only in the intervals between HIFU exposure but also, for some configurations, during the exposure itself. 2010 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Durmuş, Büşra; Heppe, Denise H M; Gishti, Olta; Manniesing, Rashindra; Abrahamse-Berkeveld, Marieke; van der Beek, Eline M; Hofman, Albert; Duijts, Liesbeth; Gaillard, Romy; Jaddoe, Vincent W V
2014-06-01
Breastfeeding may have a protective effect on the development of obesity in later life. Not much is known about the effects of infant feeding on more-specific fat measures. We examined associations of breastfeeding duration and exclusiveness and age at the introduction of solid foods with general and abdominal fat outcomes in children. We performed a population-based, prospective cohort study in 5063 children. Information about infant feeding was obtained by using questionnaires. At the median age of 6.0 y (95% range: 5.7 y, 6.8 y), we measured childhood anthropometric measures, total fat mass and the android:gynoid fat ratio by using dual-energy X-ray absorptiometry, and preperitoneal abdominal fat by using ultrasound. We observed that, in the models adjusted for child age, sex, and height only, a shorter breastfeeding duration, nonexclusive breastfeeding, and younger age at the introduction of solid foods were associated with higher childhood general and abdominal fat measures (P-trend < 0.05) but not with higher childhood body mass index. The introduction of solid foods at a younger age but not breastfeeding duration or exclusivity was associated with higher risk of overweight or obesity (OR: 2.05; 95% CI: 1.41, 2.90). After adjustment for family-based sociodemographic, maternal lifestyle, and childhood factors, the introduction of solid food between 4 and 4.9 mo of age was associated with higher risks of overweight or obesity, but the overall trend was not significant. Associations of infant breastfeeding and age at the introduction of solid foods with general and abdominal fat outcomes are explained by sociodemographic and lifestyle-related factors. Whether infant dietary composition affects specific fat outcomes at older ages should be further studied. © 2014 American Society for Nutrition.
Terada, Masaki; Matsushita, Hiroki; Oosugi, Masanori; Inoue, Kazuyasu; Yaegashi, Taku; Anma, Takeshi
2009-03-20
The advantage of the higher signal-to-noise ratio (SNR) of 3-Tesla magnetic resonance imaging (3-Tesla) has the possibility of contributing to the improvement of high spatial resolution without causing image deterioration. In this study, we compared SNR and the apparent diffusion coefficient (ADC) value with 3-Tesla as the condition in the diffusion-weighted image (DWI) parameter of the 1.5-Tesla magnetic resonance imaging (1.5-Tesla) and we examined the high spatial resolution images in the imaging method [respiratory-triggering (RT) method and breath free (BF) method] and artifact (motion and zebra) in the upper abdominal region of DWI at 3-Tesla. We have optimized scan parameters based on phantom and in vivo study. As a result, 3-Tesla was able to obtain about 1.5 times SNR in comparison with the 1.5-Tesla, ADC value had few differences. Moreover, the RT method was effective in correcting the influence of respiratory movement in comparison with the BF method, and image improvement by the effective acquisition of SNR and reduction of the artifact were provided. Thus, DWI of upper abdominal region was a useful sequence for the high spatial resolution in 3-Tesla.
Cupek, Rafal; Ziębiński, Adam
2016-01-01
Rheumatoid arthritis is the most common rheumatic disease with arthritis, and causes substantial functional disability in approximately 50% patients after 10 years. Accurate measurement of the disease activity is crucial to provide an adequate treatment and care to the patients. The aim of this study is focused on a computer aided diagnostic system that supports an assessment of synovitis severity. This paper focus on a computer aided diagnostic system that was developed within joint Polish-Norwegian research project related to the automated assessment of the severity of synovitis. Semiquantitative ultrasound with power Doppler is a reliable and widely used method of assessing synovitis. Synovitis is estimated by ultrasound examiner using the scoring system graded from 0 to 3. Activity score is estimated on the basis of the examiner's experience or standardized ultrasound atlases. The method needs trained medical personnel and the result can be affected by a human error. The porotype of a computer-aided diagnostic system and algorithms essential for an analysis of ultrasonic images of finger joints are main scientific output of the MEDUSA project. Medusa Evaluation System prototype uses bone, skin, joint and synovitis area detectors for mutual structural model based evaluation of synovitis. Finally, several algorithms that support the semi-automatic or automatic detection of the bone region were prepared as well as a system that uses the statistical data processing approach in order to automatically localize the regions of interest. Semiquantitative ultrasound with power Doppler is a reliable and widely used method of assessing synovitis. Activity score is estimated on the basis of the examiner's experience and the result can be affected by a human error. In this paper we presented the MEDUSA project which is focused on a computer aided diagnostic system that supports an assessment of synovitis severity.
Holistic ultrasound in trauma: An update.
Saranteas, Theodosios; Mavrogenis, Andreas F
2016-10-01
Holistic ultrasound is a total body examination using an ultrasound device aiming to achieve immediate patient care and decision making. In the setting of trauma, it is one of the most fundamental components of care of the injured patients. Ground-breaking imaging software allows physicians to examine various organs thoroughly, recognize imaging signs early, and potentially foresee the onset or the possible outcome of certain types of injuries. Holistic ultrasound can be performed on a routine basis at the bedside of the patients, at admission and during the perioperative period. Trauma care physicians should be aware of the diagnostic and guidance benefits of ultrasound and should receive appropriate training for the optimal management of their patients. In this paper, the findings of holistic ultrasound in trauma patients are presented, with emphasis on the lungs, heart, cerebral circulation, abdomen, and airway. Additionally, the benefits of ultrasound imaging in interventional anaesthesia techniques such as ultrasound-guided peripheral nerve blocks and central vein catheterization are described. Copyright © 2016 Elsevier Ltd. All rights reserved.
Steinmetz, Peter; Oleskevich, Sharon; Dyachenko, Alina; McCusker, Jane; Lewis, John
2018-03-25
This study compared the accuracy of medical students in identifying pleural effusion in hospitalized patients using the physical examination versus lung ultrasound (US). Fourth-year medical students (n = 14) received 20 hours of general practical US training (including 2 hours of specialized lung US training) plus theoretical and video documentation. The students used the physical examination alone versus the physical examination plus lung US to document the presence or absence of pleural effusion in the right and left hemithoraces of hospitalized patients (n = 11 patients; 22 hemithoraces examined 544 times in total). The reference standard for identification of pleural effusion was a lung US examination by 2 expert point-of-care sonographers. The odds of correctly identifying the presence versus absence of pleural effusion was 5 times greater with lung US as an adjunct to the physical examination compared to the physical examination alone (odds ratio [OR], 5.1 from multivariate logistic regression; 95% confidence interval, 3.3-8.0). The addition of lung US to the physical examination resulted in an increase in sensitivity from 48% to 90%, in specificity from 73% to 86%, and in accuracy from 60% to 88%. The benefits of using US were greater when pleural effusion was present versus absent (OR, 10.8 versus 2.4) and when examining older versus younger patients (OR, 10.2 versus 2.8). These results demonstrate that medical students' ability to detect the presence or absence of pleural effusion is superior when using lung US as an adjunct to the physical examination than when using the physical examination alone. © 2018 by the American Institute of Ultrasound in Medicine.
Ultrasound guidance system for prostate biopsy
NASA Astrophysics Data System (ADS)
Hummel, Johann; Kerschner, Reinhard; Kaar, Marcus; Birkfellner, Wolfgang; Figl, Michael
2017-03-01
We designed a guidance system for prostate biopsy based on PET/MR images and 3D ultrasound (US). With our proposed method common inter-modal MR-US (or CT-US in case of PET/CTs) registration can be replaced by an intra-modal 3D/3D-US/US registration and an optical tracking system (OTS). On the pre-operative site, a PET/MR calibration allows to link both hybrid modalities with an abdominal 3D-US. On the interventional site, another abdominal 3D US is taken to merge the pre-operative images with the real-time 3D-US via 3D/3D-US/US registration. Finally, the images of a tracked trans-rectal US probe can be displayed with the pre-operative images by overlay. For PET/MR image fusion we applied a point-to-point registration between PET and OTS and MR and OTS, respectively. 3D/3D-US/US registration was evaluated for images taken in supine and lateral patient position. To enable table shifts between PET/MR and US image acquisition a table calibration procedure is presented. We found fiducial registration errors of 0.9 mm and 2.8 mm, respectively, with respect to the MR and PET calibration. A target registration error between MR and 3D US amounted to 1.4 mm. The registration error for the 3D/3D-US/US registration was found to be 3.7 mm. Furthermore, we have shown that ultrasound is applicable in an MR environment.
Smarr, Melissa M.; Vadillo-Ortega, Felipe; Castillo-Castrejon, Marisol; O’Neill, Marie S.
2015-01-01
Purpose of review Recently, several international research groups have suggested that studies about environmental contaminants and adverse pregnancy outcomes should be designed to elucidate potential underlying biological mechanisms. The purpose of this review is to examine the epidemiological studies addressing maternal exposure to air pollutants and fetal growth during gestation as assessed by ultrasound measurements. Recent findings The six studies published to date found that exposure to certain ambient air pollutants during pregnancy is negatively associated with the growth rates and average attained size of fetal parameters belonging to the growth profile. Fetal parameters may respond to maternal air pollution exposures uniquely, and this response may vary by pollutant and timing of gestational exposure. Current literature suggests that mean changes in head circumference, abdominal circumference, femur length, and biparietal diameter are negatively associated with early-pregnancy exposures to ambient and vehicle-related air pollution. Summary The use of more longitudinal studies, employing ultrasound measures to assess fetal outcomes, may assist with the better understanding of mechanisms responsible for air pollution-related pregnancy outcomes. PMID:23399571
Congenital heart disease manifested as acute abdominal pain.
Macha, Mahender; Gupta, Dipin; Molina, Ezequiel; Palma, Jon; Rothman, Steven
2007-06-12
We present a case of a 53-year-old man with complaints of severe abdominal pain and nausea. Emergency department abdominal workup was non-diagnostic. Physical examination revealed signs of right- and left-heart failure. A past medical history of dysrhythmias and chronic abdominal complaints prompted hospital admission. Subsequent right heart catheterization revealed a significant left-to-right shunt. CT scan of the chest and angiography confirmed the diagnosis of an abnormal ascending vein between the innominate vein and the left superior pulmonary vein. After the anomalous vein was ligated, the patient's abdominal pain resolved.
Rizzo, Giuseppe; Capponi, Alessandra; Pietrolucci, Maria Elena; Capece, Giuseppe; Cimmino, Ernesto; Colosi, Enrico; Ferrentino, Salvatore; Sica, Carmine; Di Meglio, Aniello; Arduini, Domenico
2011-01-01
The aim of this study was to evaluate the feasibility of visualizing standard cardiac views from 4-dimensional (4D) cardiac volumes obtained at ultrasound facilities with no specific experience in fetal echocardiography. Five sonographers prospectively recorded 4D cardiac volumes starting from the 4-chamber view on 500 consecutive pregnancies at 19 to 24 weeks' gestation undergoing routine ultrasound examinations (100 pregnancies for each sonographer). Volumes were sent to the referral center, and 2 independent reviewers with experience in 4D fetal echocardiography assessed their quality in the display of the abdominal view, 4-chamber view, left and right ventricular outflow tracts, and 3-vessel and trachea view. Cardiac volumes were acquired in 474 of 500 pregnancies (94.8%). The 2 reviewers respectively acknowledged the presence of satisfactory images in 92.4% and 93.6% of abdominal views, 91.5% and 93.0% of 4-chamber views, in 85.0% and 86.2% of left ventricular outflow tracts, 83.9% and 84.5% of right ventricular outflow tracts, and 85.2% and 84.5% of 3-vessel and trachea views. The presence of a maternal body mass index of greater than 30 altered the probability of achieving satisfactory cardiac views, whereas previous maternal lower abdominal surgery did not affect the quality of reconstructed cardiac views. In conclusion, cardiac volumes acquired by 4D sonography in peripheral centers showed high enough quality to allow satisfactory diagnostic cardiac views.
Peritoneal tap; Paracentesis; Ascites - abdominal tap; Cirrhosis - abdominal tap; Malignant ascites - abdominal tap ... abdominal cavity ( most often cancer of the ovaries ) Cirrhosis of the liver Damaged bowel Heart disease Infection ...
Rosenkrantz, Andrew B; Johnson, Evan; Sanger, Joseph J
2015-10-01
This article presents our local experience in the implementation of a real-time web-based system for reporting and tracking quality issues relating to abdominal imaging examinations. This system allows radiologists to electronically submit examination quality issues during clinical readouts. The submitted information is e-mailed to a designate for the given modality for further follow-up; the designate may subsequently enter text describing their response or action taken, which is e-mailed back to the radiologist. Review of 558 entries over a 6-year period demonstrated documentation of a broad range of examination quality issues, including specific issues relating to protocol deviation, post-processing errors, positioning errors, artifacts, and IT concerns. The most common issues varied among US, CT, MRI, radiography, and fluoroscopy. In addition, the most common issues resulting in a patient recall for repeat imaging (generally related to protocol deviation in MRI and US) were identified. In addition to submitting quality problems, radiologists also commonly used the tool to provide recognition of a well-performed examination. An electronic log of actions taken in response to radiologists' submissions indicated that both positive and negative feedback were commonly communicated to the performing technologist. Information generated using the tool can be used to guide subsequent quality improvement initiatives within a practice, including continued protocol standardization as well as education of technologists in the optimization of abdominal imaging examinations.
Fuchs, F; Houllier, M; Voulgaropoulos, A; Levaillant, J-M; Colmant, C; Bouyer, J; Senat, M-V
2013-01-01
To evaluate the feasibility of completing in one session a second-trimester ultrasound scan in obese pregnant women, to compare the quality of images obtained with those of non-obese women and to analyze factors that can improve the completion rate. This prospective study, from 2009 to 2011, included all obese pregnant women (prepregnancy body mass index (BMI) > 30 kg/m2) who had an ultrasound examination at 20-24 weeks in our department, and a control group of pregnant women with normal BMI (20-24.9 kg/m2) who had the same examination. A single operator reviewed the standardized ultrasound images (three biometric and six to assess key anatomical features) required under French guidelines, to assess their presence, evaluate the quality of all images and score the quality of the six anatomical images. Each image was assessed according to between four and six criteria, each worth one point. We sought excellent quality, defined as the frequency of maximum points for a given image type. The factors associated with completing the scan in one session were evaluated with multivariate logistic regression. The obese group included 223 women and the control group 60; a complete scan in one session was achieved in 70.4% and 81.7% of these, respectively (P = 0.08). The completion rate for each image type was at least 95% in the control group and 90% in the obese group, except for diaphragm and right outflow tract images. Significant factors associated with completing the scan in the multivariate model were: having 10 additional minutes for the scan (P = 0.03), moving the fetus so that the back was in posterior or lateral position (P = 0.01), more experienced sonographer (P = 0.03) and thinner maternal abdominal wall thickness (P = 0.01). Overall, the excellence rate varied from 35% to 92% in the normal BMI group and from 18% to 58% in the obese group, and was significantly lower in the latter for all images except abdominal circumference (P
Staged abdominal re-operation for abdominal trauma.
Taviloglu, Korhan
2003-07-01
To review the current developments in staged abdominal re-operation for abdominal trauma. To overview the steps of damage control laparotomy. The ever increasing importance of the resuscitation phase with current intensive care unit (ICU) support techniques should be emphasized. General surgeons should be familiar to staged abdominal re-operation for abdominal trauma and collaborate with ICU teams, interventional radiologists and several other specialties to overcome this entity.
Ultrasound imaging in the management of bleeding and pain in early pregnancy.
Knez, Jure; Day, Andrea; Jurkovic, Davor
2014-07-01
Bleeding and pain are experienced by 20% of women during the first trimester of pregnancy. Although most pregnancies complicated by pain and bleeding tend to progress normally, these symptoms are distressing for woman, and they are also associated with an increased risk of miscarriage and ectopic pregnancy. Ultrasound is the first and often the only diagnostic modality that is used to determine location of early pregnancy and to assess its health. Ultrasound is an accurate, safe, painless and relatively inexpensive diagnostic tool, which all contributed to its widespread use in early pregnancy. Pain and bleeding in early pregnancy are sometimes caused by concomitant gynaecological, gastrointestinal, and urological problems, which could also be detected on ultrasound scan. In women with suspected intra-abdominal bleeding, ultrasound scan can be used to detect the presence of blood and provide information about the extent of bleeding. In this chapter, we comprehensively review the use of ultrasound in the diagnosis and management of early pregnancy complications. We include information about the diagnosis of gynaecological and other pelvic abnormalities, which could cause pain or bleeding in pregnancy. We also provide a summary of the current views on the safety of ultrasound in early pregnancy. Copyright © 2014 Elsevier Ltd. All rights reserved.
Integrated medical school ultrasound: development of an ultrasound vertical curriculum.
Bahner, David P; Adkins, Eric J; Hughes, Daralee; Barrie, Michael; Boulger, Creagh T; Royall, Nelson A
2013-07-02
Physician-performed focused ultrasonography is a rapidly growing field with numerous clinical applications. Focused ultrasound is a clinically useful tool with relevant applications across most specialties. Ultrasound technology has outpaced the education, necessitating an early introduction to the technology within the medical education system. There are many challenges to integrating ultrasound into medical education including identifying appropriately trained faculty, access to adequate resources, and appropriate integration into existing medical education curricula. As focused ultrasonography increasingly penetrates academic and community practices, access to ultrasound equipment and trained faculty is improving. However, there has remained the major challenge of determining at which level is integrating ultrasound training within the medical training paradigm most appropriate. The Ohio State University College of Medicine has developed a novel vertical curriculum for focused ultrasonography which is concordant with the 4-year medical school curriculum. Given current evidenced-based practices, a curriculum was developed which provides medical students an exposure in focused ultrasonography. The curriculum utilizes focused ultrasonography as a teaching aid for students to gain a more thorough understanding of basic and clinical science within the medical school curriculum. The objectives of the course are to develop student understanding in indications for use, acquisition of images, interpretation of an ultrasound examination, and appropriate decision-making of ultrasound findings. Preliminary data indicate that a vertical ultrasound curriculum is a feasible and effective means of teaching focused ultrasonography. The foreseeable limitations include faculty skill level and training, initial cost of equipment, and incorporating additional information into an already saturated medical school curriculum. Focused ultrasonography is an evolving concept in medicine
Amer, Mohammed S; Hassan, Elham A; Torad, Faisal A
2018-02-20
Five female egg-laying pigeons presented with painless, reducible, ventral abdominal swellings located between the keel and the pubis, or close to the cloaca. Based on clinical, radiographic, and ultrasonographic examination, these pigeons were diagnosed with ventral abdominal hernia requiring surgical interference. Reduction was successfully performed under general anesthesia. Radiographic and ultrasonographic examinations were beneficial for confirming the diagnosis and visualizing the hernial content for surgical planning. Lateral radiographs were more helpful than ventrodorsal radiographs for identification of the hernial content and its continuation with the abdominal muscles. Ultrasonographic examination offered a non-invasive diagnostic tool that allowed for the differentiation of hernia from other abdominal swellings. In addition, it played a beneficial role in identification of the hernial content and follow up after surgical interference. In conclusion, radiographic and ultrasonographic examinations were beneficial in the diagnosis, surgical planning, and follow up after surgical interference of ventral abdominal hernia in pigeons.
Relative Activity of Abdominal Muscles during Commonly Prescribed Strengthening Exercises.
ERIC Educational Resources Information Center
Willett, Gilbert M.; Hyde, Jennifer E.; Uhrlaub, Michael B.; Wendel, Cara L.; Karst, Gregory M.
2001-01-01
Examined the relative electromyographic (EMG) activity of upper and lower rectus abdominis (LRA) and external oblique (EOA) muscles during five abdominal strengthening exercises. Isometric and dynamic EMG data indicated that abdominal strengthening exercises activated various abdominal muscle groups. For the LRA and EOA muscle groups, there were…
França, Giovanny Vinícius Araújo de; De Lucia Rolfe, Emanuella; Horta, Bernardo Lessa; Gigante, Denise Petrucci; Yudkin, John S; Ong, Ken K; Victora, Cesar Gomes
2017-01-01
We aimed to identify the independent associations of genomic ancestry and education level with abdominal fat distributions in the 1982 Pelotas birth cohort study, Brazil. In 2,890 participants (1,409 men and 1,481 women), genomic ancestry was assessed using genotype data on 370,539 genome-wide variants to quantify ancestral proportions in each individual. Years of completed education was used to indicate socio-economic position. Visceral fat depth and subcutaneous abdominal fat thickness were measured by ultrasound at age 29-31y; these measures were adjusted for BMI to indicate abdominal fat distributions. Linear regression models were performed, separately by sex. Admixture was observed between European (median proportion 85.3), African (6.6), and Native American (6.3) ancestries, with a strong inverse correlation between the African and European ancestry scores (ρ = -0.93; p<0.001). Independent of education level, African ancestry was inversely associated with both visceral and subcutaneous abdominal fat distributions in men (both P = 0.001), and inversely associated with subcutaneous abdominal fat distribution in women (p = 0.009). Independent of genomic ancestry, higher education level was associated with lower visceral fat, but higher subcutaneous fat, in both men and women (all p<0.001). Our findings, from an admixed population, indicate that both genomic ancestry and education level were independently associated with abdominal fat distribution in adults. African ancestry appeared to lower abdominal fat distributions, particularly in men.
De Lucia Rolfe, Emanuella; Horta, Bernardo Lessa; Gigante, Denise Petrucci; Yudkin, John S.; Ong, Ken K.; Victora, Cesar Gomes
2017-01-01
We aimed to identify the independent associations of genomic ancestry and education level with abdominal fat distributions in the 1982 Pelotas birth cohort study, Brazil. In 2,890 participants (1,409 men and 1,481 women), genomic ancestry was assessed using genotype data on 370,539 genome-wide variants to quantify ancestral proportions in each individual. Years of completed education was used to indicate socio-economic position. Visceral fat depth and subcutaneous abdominal fat thickness were measured by ultrasound at age 29–31y; these measures were adjusted for BMI to indicate abdominal fat distributions. Linear regression models were performed, separately by sex. Admixture was observed between European (median proportion 85.3), African (6.6), and Native American (6.3) ancestries, with a strong inverse correlation between the African and European ancestry scores (ρ = -0.93; p<0.001). Independent of education level, African ancestry was inversely associated with both visceral and subcutaneous abdominal fat distributions in men (both P = 0.001), and inversely associated with subcutaneous abdominal fat distribution in women (p = 0.009). Independent of genomic ancestry, higher education level was associated with lower visceral fat, but higher subcutaneous fat, in both men and women (all p<0.001). Our findings, from an admixed population, indicate that both genomic ancestry and education level were independently associated with abdominal fat distribution in adults. African ancestry appeared to lower abdominal fat distributions, particularly in men. PMID:28582437
Volunteer patients and small groups contribute to abdominal examination’s success
Shields, Helen M; Fernandez-Becker, Nielsen Q; Flier, Sarah N; Vaughn, Byron P; Tukey, Melissa H; Pelletier, Stephen R; Horst, Douglas A
2017-01-01
Background Prior to 2007, we taught the abdominal examination in a hospital based group to 40 students, at one hospital. We used volunteer patients, small groups, repetition, and required faculty development sessions. In 2007, our medical school changed its “Introduction to Physical Examination” session so that the entire class was to be taught in a geographically central session. Our hospital was selected to lead the abdominal examination portion of the session. Aim Our aim was to answer three questions. First, could we quadruple the recruitment of volunteer patients, and faculty? Second, was it volunteer patients, small groups, repetition, or faculty training that was most valued by the students? Third, would volunteer patients and/or faculty agree to participate a second time? Methods A total of 43–46 patients and 43–46 faculty were recruited and 43–46 examining rooms were obtained for each of the 5 years of this study. Teachers were required to attend a 1-hour faculty development session. The class of about 170 students was divided into 43–46 groups each year. The teacher demonstrated the abdominal examination and each student practiced the examination on another student. Each student then repeated the full abdominal examination on a volunteer patient. Results Over the 5-year time period (2008–2012), the abdominal examination ranked first among all organ systems’ “Introductory Sessions”. The abdominal examination ratings had the best mean score (1.35) on a Likert scale where 1 is excellent and 5 is poor. The students gave the most positive spontaneous comments to having volunteer patients, with small groups coming in as the second most appreciated educational element. Conclusion We successfully quadrupled the number of faculty, patients, and examining rooms and created a highly rated educational program as measured by anonymous student evaluations, patient and faculty participation, and the medical school’s selecting the abdominal
Jung, Halim; Jung, Sangwoo; Joo, Sunghee; Song, Changho
2016-01-01
[Purpose] The purpose of this study was to compare changes in the mobility of the pelvic floor muscle during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. [Subjects] Thirty healthy adults participated in this study (15 men and 15 women). [Methods] All participants performed a bridge exercise and abdominal curl-up during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. Pelvic floor mobility was evaluated as the distance from the bladder base using ultrasound. [Results] According to exercise method, bridge exercise and abdominal curl-ups led to significantly different pelvic floor mobility. The pelvic floor muscle was elevated during the abdominal drawing-in maneuver and descended during maximal expiration. Finally, pelvic floor muscle mobility was greater during abdominal curl-up than during the bridge exercise. [Conclusion] According to these results, the abdominal drawing-in maneuver induced pelvic floor muscle contraction, and pelvic floor muscle contraction was greater during the abdominal curl-up than during the bridge exercise.
Recovery after abdominal wall reconstruction.
Jensen, Kristian Kiim
2017-03-01
Incisional hernia is a common long-term complication to abdominal surgery, occurring in more than 20% of all patients. Some of these hernias become giant and affect patients in several ways. This patient group often experiences pain, decreased perceived body image, and loss of physical function, which results in a need for surgical repair of the giant hernia, known as abdominal wall reconstruction. In the current thesis, patients with a giant hernia were examined to achieve a better understanding of their physical and psychological function before and after abdominal wall reconstruction. Study I was a systematic review of the existing standardized methods for assessing quality of life after incisional hernia repair. After a systematic search in the electronic databases Embase and PubMed, a total of 26 studies using standardized measures for assessment of quality of life after incisional hernia repair were found. The most commonly used questionnaire was the generic Short-Form 36, which assesses overall health-related quality of life, addressing both physical and mental health. The second-most common questionnaire was the Carolinas Comfort Scale, which is a disease specific questionnaire addressing pain, movement limitation and mesh sensation in relation to a current or previous hernia. In total, eight different questionnaires were used at varying time points in the 26 studies. In conclusion, standardization of timing and method of quality of life assessment after incisional hernia repair was lacking. Study II was a case-control study of the effects of an enhanced recovery after surgery pathway for patients undergoing abdominal wall reconstruction for a giant hernia. Sixteen consecutive patients were included prospectively after the implementation of a new enhanced recovery after surgery pathway at the Digestive Disease Center, Bispebjerg Hospital, and compared to a control group of 16 patients included retrospectively in the period immediately prior to the
Ultrasound in twin pregnancies.
Morin, Lucie; Lim, Kenneth
2011-06-01
and normal assessment. (III) 2. There are insufficient data to recommend a routine preterm labour surveillance protocol in terms of frequency, timing, and optimal cervical length thresholds. (II-2) 3. Singleton growth curves currently provide the best predictors of adverse outcome in twins and may be used for evaluating growth abnormalities. (III) 4. It is suggested that growth discordance be defined using either a difference (20 mm) in absolute measurement in abdominal circumference or a difference of 20% in ultrasound-derived estimated fetal weight. (II-2) 5. Although there is insufficient evidence to recommend a specific schedule for ultrasound assessment of twin gestation, most experts recommend serial ultrasound assessment every 2 to 3 weeks, starting at 16 weeks of gestation for monochorionic pregnancies and every 3 to 4 weeks, starting from the anatomy scan (18 to 22 weeks) for dichorionic pregnancies. (II-1) 6. Umbilical artery Doppler may be useful in the surveillance of twin gestations when there are complications involving the placental circulation or fetal hemodynamic physiology. (II-2) 7. Although many methods of evaluating the level of amniotic fluid in twins (deepest vertical pocket, single pocket, amniotic fluid index) have been described, there is not enough evidence to suggest that one method is more predictive than the others of adverse pregnancy outcome. (II-3) 8. Referral to an appropriate high-risk pregnancy centre is indicated when complications unique to twins are suspected on ultrasound. (II-2) These complications include: 1. Twin-to-twin transfusion syndrome 2. Monoamniotic twins gestation 3. Conjoined twins 4. Twin reversed arterial perfusion sequence 5. Single fetal death in the second or third trimester 6. Growth discordance in monochorionic twins. Recommendations 1. All patients who are suspected to have a twin pregnancy on first trimester physical examination or who are at risk (e.g., pregnancies resulting from assisted reproductive
Lunceford, Nicole; Scherl, Robert J; Elliot, Jonathan; Bechtel, Brett F; Auten, Jonathan
2013-03-01
The role of bedside ultrasound by physicians with advanced ultrasound training, such as emergency medicine providers, has been clearly established in the austere setting of combat medicine. This highly mobile, noninvasive, and versatile imaging modality has a role in evaluating battle- and nonbattle-related presentations. This case report describes a U.S. Marine reporting to an austere medical facility with the chief complaint of abdominal pain. An ultrasound of the patient's urinary tract revealed abnormalities that suggested right bladder wall thickening and an echo dense layer of sediment as the potential source of his discomfort. These findings supported patient transfer to a higher echelon of care. Further diagnostic testing revealed Crohn's disease with an associated enterovesicular fistula. Reprint & Copyright © 2013 Association of Military Surgeons of the U.S.
[Clinical Approach to Abdominal Pain as Functional Origin].
Ryu, Han Seung; Choi, Suck Chei
2018-02-25
Abdominal pain is a common symptom that patients refer to a hospital. Organic causes should be differentiated in patients with abdominal pain and treatment should be administered in accordance with the causes. A meticulous history taking and physical examination are highly useful in making a diagnosis, and blood tests, imaging modalities, and endoscopy are useful for confirming diagnosis. However, in many cases, patients have functional disorders with no obvious abnormal findings obtained even if many diagnostic tests are performed. Patients with functional disorders usually complain the vague abdominal pain located in the center and other portions of the abdominal area. Although the most representative disease is irritable bowel syndrome, functional abdominal pain syndrome is currently researched as a new disease entity of functional abdominal pain. As various receptors related to functional abdominal pain have been discovered, drugs associated with those receptors are used to treat the disorders, and additional new drugs are vigorously developed. In addition, medical therapy with pharmacological or non-pharmacological psychiatric treatment is effective for treating functional abdominal pain.
Mortimer, Alice Emily
2014-11-14
A 79-year-old woman presented to a private medical practice 2 years previously for an elective ultrasound screening scan. This imaging provided the evidence for a diagnosis of an abdominal aortic aneurysm (AAA) to be made. Despite having a number of recognised risk factors for an AAA, her general practitioner at the time did not follow the guidance set out by the private medical professional, that is, to refer the patient to a vascular specialist to be entered into a surveillance programme and surgically evaluated. The patient became symptomatic with her AAA, was admitted to hospital and found to have a tender, symptomatic, 6 cm leaking AAA. She consented for an emergency open AAA repair within a few hours of being admitted to hospital, despite the 50% perioperative mortality risk. The patient spent 4 days in intensive care where she recovered well. She was discharged after a 12 day hospital stay but unfortunately passed away shortly after her discharge from a previously undiagnosed gastric cancer. 2014 BMJ Publishing Group Ltd.
Mortimer, Alice Emily
2014-01-01
A 79-year-old woman presented to a private medical practice 2 years previously for an elective ultrasound screening scan. This imaging provided the evidence for a diagnosis of an abdominal aortic aneurysm (AAA) to be made. Despite having a number of recognised risk factors for an AAA, her general practitioner at the time did not follow the guidance set out by the private medical professional, that is, to refer the patient to a vascular specialist to be entered into a surveillance programme and surgically evaluated. The patient became symptomatic with her AAA, was admitted to hospital and found to have a tender, symptomatic, 6 cm leaking AAA. She consented for an emergency open AAA repair within a few hours of being admitted to hospital, despite the 50% perioperative mortality risk. The patient spent 4 days in intensive care where she recovered well. She was discharged after a 12 day hospital stay but unfortunately passed away shortly after her discharge from a previously undiagnosed gastric cancer. PMID:25398912
Measurement of tissue viscoelasticity with ultrasound
NASA Astrophysics Data System (ADS)
Greenleaf, J. F.; Alizad, A.
2017-02-01
Tissue properties such as elasticity and viscosity have been shown to be related to such tissue conditions as contraction, edema, fibrosis, and fat content among others. Magnetic Resonance Elastography has shown outstanding ability to measure the elasticity and in some cases the viscosity of tissues, especially in the liver, providing the ability to stage fibrotic liver disease similarly to biopsy. We discuss ultrasound methods of measuring elasticity and viscosity in tissues. Many of these methods are becoming widely available in the extant ultrasound machines distributed throughout the world. Some of the methods to be discussed are in the developmental stage. The advantages of the ultrasound methods are that the imaging instruments are widely available and that many of the viscoelastic measurements can be made during a short addition to the normal ultrasound examination time. In addition, the measurements can be made by ultrasound repetitively and quickly allowing evaluation of dynamic physiologic function in circumstances such as muscle contraction or artery relaxation. Measurement of viscoelastic tissue mechanical properties will become a consistent part of clinical ultrasound examinations in our opinion.
Point-of-Care Ultrasound: A Trend in Health Care.
Buerger, Anita M; Clark, Kevin R
2017-11-01
To discuss the current and growing use of point-of-care (POC) ultrasound in the management and care of patients. Several electronic research databases were searched to find articles that emphasized the use of POC ultrasound by health care providers who manage and treat critically ill or injured patients. Thirty-five relevant peer-reviewed journal articles were selected for this literature review. Common themes identified in the literature included the use of POC ultrasound in emergency medicine, military medicine, and remote care; comparison of POC ultrasound to other medical imaging modalities; investigation of the education and training required for nonimaging health care professionals who perform POC ultrasound in their practices; and discussion of the financial implications and limitations of POC ultrasound. POC ultrasound provides clinicians with real-time information to better manage and treat critically ill or injured patients in emergency medicine, military medicine, and remote care. In addition to providing immediate bedside diagnostic information, use of POC ultrasound has increased because of concerns regarding radiation protection. Finally, the expansion of POC ultrasound to other specialty areas requires nonimaging health care professionals to perform bedside ultrasound examinations and interpret the resulting images. Because POC ultrasound is user-dependent, adequate training is essential for all who perform and interpret the examinations. Research involving POC ultrasound will continue as innovations and confidence in ultrasound applications advance. Future research should continue to examine the broad use of POC ultrasound in patient care and management. ©2017 American Society of Radiologic Technologists.
Estimation of prenatal aorta intima-media thickness in ultrasound examination
NASA Astrophysics Data System (ADS)
Veronese, Elisa; Poletti, Enea; Cosmi, Erich; Grisan, Enrico
2012-03-01
Prenatal events such as intrauterine growth restriction have been shown to be associated with an increased thickness of abdominal aorta in the fetus. Therefore the measurement of abdominal aortic intima-media thickness (aIMT) has been recently considered a sensitive marker of artherosclerosis risk. To date measure of aortic diameter and of aIMT has been performed manually on US fetal images, thus being susceptible to intra- and inter- operator variability. This work introduces an automatic algorithm that identifies abdominal aorta and estimates its diameter and aIMT from videos recorded during routine third trimester ultrasonographic fetal biometry. Firstly, in each frame, the algorithm locates and segments the region corresponding to aorta by means of an active contour driven by two different external forces: a static vector field convolution force and a dynamic pressure force. Then, in each frame, the mean diameter of the vessel is computed, to reconstruct the cardiac cycle: in fact, we expect the diameter to have a sinusoidal trend, according to the heart rate. From the obtained sinusoid, we identify the frames corresponding to the end diastole and to the end systole. Finally, in these frames we assess the aIMT. According to its definition, we consider as aIMT the distance between the leading edge of the blood-intima interface, and the leading edge of the media-adventitia interface on the far wall of the vessel. The correlation between end-diastole and end-systole aIMT automatic and manual measures is 0.90 and 0.84 respectively.
Objective diagnosis of arrested labor on transperineal ultrasound.
Nishimura, Kazuaki; Yoshimura, Kazuaki; Kubo, Tatsuhiko; Hachisuga, Toru
2016-07-01
Recent developments in transperineal ultrasound imaging of the pelvis have prompted trials to objectively evaluate labor progression for labor management. We evaluated the accuracy of transperineal ultrasound in diagnosing arrest of labor. Transperineal ultrasound and digital pelvic examinations were performed simultaneously in 63 term laboring patients (singleton fetuses in cephalic presentation). We analyzed a total of 216 ultrasound images (Sonography Volume Computer Aided Display Labor [Sono VCAD Labor®] installed in Voluson E8 ultrasound). We examined the correlation between the three ultrasound parameters head direction (HD), progression distance (PD), and progression angle (PA), and digital pelvic examination findings during labor in a transvaginal delivery group and an arrested labor group. The coefficient of correlations between HD/PD/PA and cervical dilation/fetal station were 0.667/0.657/0.706 and 0.667/0.751/0.803, respectively. The three parameters had strong correlations with digital pelvic examination (P < 0.05). In the 11 cases (17%) of cesarean section due to arrested labor, the position of the fetal head was visually unchanged on sequential ultrasound images. According to receiver operating characteristic curves, the significant cut-offs for HD, PD, and PA for arrested labor were 105° (P = 0.048), 35 mm (P = 0.048), and 120° (P = 0.001), respectively. Transperineal ultrasound imaging is helpful for objective evaluation of labor progression and the diagnosis of arrested labor. © 2016 Japan Society of Obstetrics and Gynecology.
Gong, Chunmei; Yang, Bin; Shi, Yarong; Liu, Zhongqiong; Wan, Lili; Zhang, Hong; Jiang, Denghua; Zhang, Lian
2016-08-01
Objectives The aim of this study was to investigate factors affecting ablative efficiency of high intensity focused ultrasound (HIFU) for adenomyosis. Materials and methods In all, 245 patients with adenomyosis who underwent ultrasound guided HIFU (USgHIFU) were retrospectively reviewed. All patients underwent dynamic contrast-enhanced magnetic resonance imaging (MRI) before and after HIFU treatment. The non-perfused volume (NPV) ratio, energy efficiency factor (EEF) and greyscale change were set as dependent variables, while the factors possibly affecting ablation efficiency were set as independent variables. These variables were used to build multiple regression models. Results A total of 245 patients with adenomyosis successfully completed HIFU treatment. Enhancement type on T1 weighted image (WI), abdominal wall thickness, volume of adenomyotic lesion, the number of hyperintense points, location of the uterus, and location of adenomyosis all had a linear relationship with the NPV ratio. Distance from skin to the adenomyotic lesion's ventral side, enhancement type on T1WI, volume of adenomyotic lesion, abdominal wall thickness, and signal intensity on T2WI all had a linear relationship with EEF. Location of the uterus and abdominal wall thickness also both had a linear relationship with greyscale change. Conclusion The enhancement type on T1WI, signal intensity on T2WI, volume of adenomyosis, location of the uterus and adenomyosis, number of hyperintense points, abdominal wall thickness, and distance from the skin to the adenomyotic lesion's ventral side can all be used as predictors of HIFU for adenomyosis.
Intestinal injury mechanisms after blunt abdominal impact.
Cripps, N P; Cooper, G J
1997-03-01
Intestinal injury is frequent after non-penetrating abdominal trauma, particularly after modern, high-energy transfer impacts. Under these circumstances, delay in the diagnosis of perforation is a major contributor to morbidity and mortality. This study establishes patterns of intestinal injury after blunt trauma by non-penetrating projectiles and examines relationships between injury distribution and abdominal wall motion. Projectile impacts of variable momentum were produced in 31 anaesthetised pigs to cause abdominal wall motion of varying magnitude and velocity. No small bowel injury was observed at initial impact velocity of less than 40 m/s despite gross abdominal compression. At higher velocity, injury to the small bowel was frequent, irrespective of the degree of abdominal compression (P = 0.00044). Large bowel injury was observed at all impact velocities and at all degrees of abdominal compression. This study confirms the potential for intestinal injury in high velocity, low momentum impacts which do not greatly compress the abdominal cavity and demonstrates apparent differences in injury mechanisms for the small bowel and colon. Familiarity with injury mechanisms may reduce delays in the diagnosis of intestinal perforation in both military and civilian situations.
[Unclear Abdominal Pain - Not Always a Gastroenterological Emergency].
Aschoff, Anna Teresa; Pech, Maciej; Fischbach, Frank; Ricke, Jens; Luani, Blerim; Braun-Dullaeus, Rüdiger Christian; Herold, Jörg
2017-04-01
History and admission findings An 84-year old patient with persistent atrial fibrillation and chronic renal failure received a subcutaneous injection with low molecular weight heparin (LMWH) during a hospital stay. Over the course of her hospitalization, the patient developed abdominal pain. There was a marked hematoma at the injection site. A large tumor was palpable in the right abdominal quadrant. Examinations Due to the significant reduction in hemoglobin, we performed a CT-angiogram of the abdomen. Diagnosis We were able to visualize an intramuscular hematoma within the rectus abdominis muscle. Therapy and clinical course After visualization with digital subtraction angiography and application of microcoils and histoacryl-glue, we were able to stop bleeding. After implantation of left atrial appendage occluder, oral anticoagulation therapy could be stopped. Conclusion LMWH-treated patients with nonspecific abdominal pain should be meticulously examined to exclude iatrogenic abdominal muscle hematoma. © Georg Thieme Verlag KG Stuttgart · New York.
Improved Contrast-Enhanced Ultrasound Imaging With Multiplane-Wave Imaging.
Gong, Ping; Song, Pengfei; Chen, Shigao
2018-02-01
Contrast-enhanced ultrasound (CEUS) imaging has great potential for use in new ultrasound clinical applications such as myocardial perfusion imaging and abdominal lesion characterization. In CEUS imaging, contrast agents (i.e., microbubbles) are used to improve contrast between blood and tissue because of their high nonlinearity under low ultrasound pressure. However, the quality of CEUS imaging sometimes suffers from a low signal-to-noise ratio (SNR) in deeper imaging regions when a low mechanical index (MI) is used to avoid microbubble disruption, especially for imaging at off-resonance transmit frequencies. In this paper, we propose a new strategy of combining CEUS sequences with the recently proposed multiplane-wave (MW) compounding method to improve the SNR of CEUS in deeper imaging regions without increasing MI or sacrificing frame rate. The MW-CEUS method emits multiple Hadamard-coded CEUS pulses in each transmission event (i.e., pulse-echo event). The received echo signals first undergo fundamental bandpass filtering (i.e., the filter is centered on the transmit frequency) to eliminate the microbubble's second-harmonic signals because they cannot be encoded by pulse inversion. The filtered signals are then Hadamard decoded and realigned in fast time to recover the signals as they would have been obtained using classic CEUS pulses, followed by designed recombination to cancel the linear tissue responses. The MW-CEUS method significantly improved contrast-to-tissue ratio and SNR of CEUS imaging by transmitting longer coded pulses. The image resolution was also preserved. The microbubble disruption ratio and motion artifacts in MW-CEUS were similar to those of classic CEUS imaging. In addition, the MW-CEUS sequence can be adapted to other transmission coding formats. These properties of MW-CEUS can potentially facilitate CEUS imaging for many clinical applications, especially assessing deep abdominal organs or the heart.
Acute abdomen in children due to extra-abdominal causes.
Tsalkidis, Aggelos; Gardikis, Stefanos; Cassimos, Dimitrios; Kambouri, Katerina; Tsalkidou, Evanthia; Deftereos, Savas; Chatzimichael, Athanasios
2008-06-01
Acute abdominal pain in children is a common cause for referral to the emergency room and for subsequent hospitalization to pediatric medical or surgical departments. There are rare occasions when the abdominal pain is derived from extra-abdominal organs or systems. The aim of the present study was to establish the most common extra-abdominal causes of acute abdominal pain. The notes of all children (1 month-14 years of age) examined for acute abdominal pain in the Accident and Emergency (A&E) Department of Alexandroupolis District University Hospital in January 2001-December 2005 were analyzed retrospectively. Demographic data, clinical signs and symptoms, and laboratory findings were recorded, as well as the final diagnosis and outcome. Of a total number of 28 124 children who were brought to the A&E department, in 1731 the main complaint was acute abdominal pain. In 51 children their symptoms had an extra-abdominal cause, the most frequent being pneumonia (n = 15), tonsillitis (n = 10), otitis media (n = 9), and acute leukemia (n = 5). Both abdominal and extra-abdominal causes should be considered by a pediatrician who is confronted with a child with acute abdominal pain.
Seatbelt sign in a case of blunt abdominal trauma; what lies beneath it?
Vailas, Michail G; Moris, Demetrios; Orfanos, Stamatios; Vergadis, Chrysovalantis; Papalampros, Alexandros
2015-10-30
The reported incidence of hollow viscus injuries (HVI) in blunt trauma patients is approximately 1%. The most common site of injury to the intestine in blunt abdominal trauma (BAT) is the small bowel followed by colon, with mesenteric injuries occurring three times more commonly than bowel injuries. Isolated colon injury is a rarely encountered condition. Clinical assessment alone in patients with suspected intestinal or mesenteric injury after blunt trauma is associated with unacceptable diagnostic delays. This is a case of a 31-year-old man, admitted to the emergency department after being the restrained driver, involved in a car accident. After initial resuscitation, focused assessment with sonography for trauma examination (FAST) was performed revealing a subhepatic mass, suspicious for intraperitoneal hematoma. A computed tomography scan (CT) that followed showed a hematoma of the mesocolon of the ascending colon with active extravasation of intravenous contrast material. An exploratory laparotomy was performed, hemoperitomeum was evacuated, and a subserosal hematoma of the cecum and ascending colon with areas of totally disrupted serosal wall was found. Hematoma of the adjacent mesocolon expanding to the root of mesenteric vessels was also noted. A right hemicolectomy along with primary ileocolonic anastomosis was performed. Patient's recovery progressed uneventfully. Identifying an isolated traumatic injury to the bowel or mesentery after BAT can be a clinical challenge because of its subtle and nonspecific clinical findings; meeting that challenge may eventually lead to a delay in diagnosis and treatment with subsequent increase in associated morbidity and mortality. Isolated colon injury is a rare finding after blunt trauma and usually accompanied by other intra-abdominal organ injuries. Abdominal 'seatbelt' sign, ecchymosis of the abdominal wall, increasing abdominal pain and distension are all associated with HVI. However, the accuracy of these findings
Ebert, Kristin M; Hewitt, Geri D; Indyk, Justin A; McCracken, Katherine A; Nahata, Leena; Jayanthi, Venkata R
2018-04-01
Patients with gonadal dysgenesis (GD) with a Y chromosome have an increased risk of gonadal neoplasm. Few data exist on the ability of imaging to detect malignancy in intra-abdominal gonads in these patients. We aimed to determine the correlation between preoperative imaging findings and gonadal pathology in GD patients with Y chromosome material. A retrospective review was performed of patients with XY or XO/XY GD who underwent gonadectomy at our institution from 2003 to 2017. Patients were assessed preoperatively with ultrasonography; some additionally underwent MRI. The series consisted of 10 patients, all with female gender and non-palpable gonads. Median age was 13.1 years (range 2.4-18.3 years). Overall, four of the ten patients (40%) had a tumor (gonadoblastoma or dysgerminoma) on final pathology. Four patients had a gonad or gonads that were definitively seen on ultrasonography. All visualized gonads were described as "normal" or "small" with the exception of one patient, who had a normal MRI. Three of the four patients in this group had a tumor on final pathology. The remaining six patients had a gonad or gonads that were not definitively visualized on ultrasound; one patient in this group had a tumor on final pathology. Overall, five of seven gonads (71%) definitively visualized on ultrasound had tumor on final pathology, and two of thirteen gonads (15%) not visualized on ultrasound had tumor on final pathology; this difference was statistically significant (p = 0.012). Three patients were imaged with MRI. Of the gonads that could be visualized on MRI, no definitive abnormalities were seen. All patients imaged with MRI had tumors on final pathology. Both ultrasound and MRI are relatively poor at identifying and characterizing intra-abdominal gonads in GD patients. The majority of patients who had a neoplasm had normal imaging findings. Gonads that were definitively visualized on ultrasound were more likely to contain neoplasms that could not be
Robotic-assisted Abdominal Cerclage Placement During Pregnancy and Its Challenges.
Menderes, Gulden; Clark, Mitchell; Clark-Donat, Lindsay; Azodi, Masoud
2015-01-01
To demonstrate a surgical video of 2 cases, in which the steps of robotic-assisted abdominal cerclage placement were delineated in one and a uterine vessel injury was repaired in the other. Step-by-step explanation of the technique using a surgical video (Canadian Task Force classification III). The procedures were performed at a teaching hospital. The first patient was a 25-year-old gravida 4 para 0, with a history of cervical incompetence, who was 13 weeks pregnant at the time of surgery. She had failed McDonald cerclage and was referred for abdominal cerclage placement. The second patient was a 32-year-old gravida 6 para 0 who was 15 weeks pregnant. She had a history of 3 second-trimester miscarriages with painless cervical dilation and had failed McDonald cerclage during her previous pregnancy. Both patients were taken to the operating room for robotic-assisted abdominal cerclage placement early in the second trimester. Robotic-assisted abdominal cerclage placement was performed with ultrasound guidance. The procedure was begun with formation of the bladder flap [1]. An avascular space between the ascending and descending branches of uterine artery, at the level of the cervicoisthmic junction, was subsequently developed. The Mersilene tape was passed through this space in a posterior-to-anterior direction and pulled taut until it was laid flat along the posterior uterine wall. Six knots were then placed with the Mersilene tape on the anterior aspect of the uterus. The free ends of the tape were trimmed and approximated with a nonabsorbable suture to prevent knot slippage. The vesicouterine reflection was then reapproximated, and correct cerclage placement was confirmed with transvaginal ultrasound. In the second case, an incidental uterine vessel injury occurred during development of the avascular space. Hemostasis was attained immediately by clamping the vessel with the fenestrated graspers. Permanent hemostasis required application of the vascular clips
Is it Time to Replace Physical Examination with a Hand-Held Ultrasound Device?
Kaul, Sanjiv
2014-01-01
Attempts at using physical examination (PE) go back centuries, with inspection, palpation, and percussion being the mainstay of this approach until 2 centuries ago when the stethoscope was invented and auscultation became probably the most important element of PE for patients with known or suspected cardiovascular disease (CVD). Despite its several limitations, PE is still used, sometimes as the only means, of evaluating and following patients with CVD. In this paper I shall argue for the substitution of this inaccurate and archaic approach by direct visualization of the heart using a hand-held ultrasound (HHU) device. I am not in any way suggesting the substitution of a comprehensive echocardiographic examination by an expert sonographer/echocardiographer by HHU in patients with significant CVD. Instead, I am arguing for the replacement of PE for evaluation of the heart at the point of care as well as at the bedside, simply because HHU is more accurate and provides more meaningful information. PMID:28465916
Is it Time to Replace Physical Examination with a Hand-Held Ultrasound Device?
Kaul, Sanjiv
2014-01-01
Attempts at using physical examination (PE) go back centuries, with inspection, palpation, and percussion being the mainstay of this approach until 2 centuries ago when the stethoscope was invented and auscultation became probably the most important element of PE for patients with known or suspected cardiovascular disease (CVD). Despite its several limitations, PE is still used, sometimes as the only means, of evaluating and following patients with CVD. In this paper I shall argue for the substitution of this inaccurate and archaic approach by direct visualization of the heart using a hand-held ultrasound (HHU) device. I am not in any way suggesting the substitution of a comprehensive echocardiographic examination by an expert sonographer/echocardiographer by HHU in patients with significant CVD. Instead, I am arguing for the replacement of PE for evaluation of the heart at the point of care as well as at the bedside, simply because HHU is more accurate and provides more meaningful information.
Incentive spirometry after abdominal surgery.
Davis, Suja P
Patients face various possible complications after abdominal surgery. This article examines best practice in guiding and teaching them how to use an incentive spirometer to facilitate recovery and prevent respiratory complications.
Maintenance of Pain in Children With Functional Abdominal Pain.
Czyzewski, Danita I; Self, Mariella M; Williams, Amy E; Weidler, Erica M; Blatz, Allison M; Shulman, Robert J
2016-03-01
A significant proportion of children with functional abdominal pain develop chronic pain. Identifying clinical characteristics predicting pain persistence is important in targeting interventions. We examined whether child anxiety and/or pain-stooling relations were related to maintenance of abdominal pain frequency and compared the predictive value of 3 methods for assessing pain-stooling relations (ie, diary, parent report, child report). Seventy-six children (7-10 years old at baseline) who presented for medical treatment of functional abdominal pain were followed up 18 to 24 months later. Baseline anxiety and abdominal pain-stooling relations based on pain and stooling diaries and child- and parent questionnaires were examined in relationship to the persistence of abdominal pain frequency. Children's baseline anxiety was not related to persistence of pain frequency. Children who, however, displayed irritable bowel syndrome (IBS) symptoms at baseline maintained pain frequency at follow-up, whereas in children in whom there was no relationship between pain and stooling, pain frequency decreased. Pain and stool diaries and parent report of pain-stooling relations were predictive of pain persistence but child-report questionnaires were not. The presence of IBS symptoms in school-age children with functional abdominal pain appears to predict persistence of abdominal pain over time, whereas anxiety does not. Prospective pain and stooling diaries and parent report of IBS symptoms were predictors of pain maintenance, but child report of symptoms was not.
NASA Astrophysics Data System (ADS)
Reyes-Ramírez, B.; García-Segundo, C.; García-Valenzuela, A.
2014-05-01
We investigate theoretically and experimentally the performance of low-noise capacitive sensors based on polyvinylidene fluoride (PVDF) piezoelectric films to sense water-borne ultrasound signals for their use in photoacoustic tomography. We derive a mechanical-to-electrical transfer function of a piezoelectric capacitor sensor of infinite lateral dimensions and arbitrary thickness assuming that an ultrasound wave is normally incident. Then, we analyse the response for obliquely incident ultrasound waves on sensors of large but finite area and derive an expression for the angle dependence of the sensor's response. We also present experimental different measurements with home-made sensors and compare with our theoretical model. We present measurements of the sensors' response to harmonic signals of variable frequency in the range from 0.5 to 50 MHz and of the angular-dependence factor at 6 MHz. Additionally, because of the scope of interest in these kinds of sensors, we also tested the sensors' response for photoacoustic perturbations. These are generated by laser pulses from directly impinging on the sensor and from ultrasound perturbations produced on neoprene by the same kind of laser pulses and then travelling through water to the sensor.
Reliability tests and guidelines for B-mode ultrasound assessment of central adiposity.
Stoner, Lee; Chinn, Victoria; Cornwall, Jon; Meikle, Grant; Page, Rachel; Lambrick, Danielle; Faulkner, James
2015-11-01
Ultrasound represents a validated and relatively inexpensive diagnostic device for assessing central adiposity; however, widespread adoption has been impeded by the lack of reliable standard operating procedures. To examine the reliability of, and describe guidelines for, ultrasound-derived recording of intra-abdominal fat thickness (IAT) and maximal preperitoneal fat thickness (PFT). Ultrasound scans were obtained from 20 adults (50% female, 26 ± 7 years, 24·5 kg/m(2) ) on three different mornings. IAT was assessed 2 cm above the umbilicus (transverse plane) measuring from linea alba to: (i) anterior aorta, (ii) posterior aorta and (iii) anterior aspect of the vertebral column. PFT was measured from linea alba to visceral peritoneum in (i) sagittal and (ii) transverse planes, immediately over and inferior to the xiphi-sternum, respectively. For IAT, the criterion intraclass correlation coefficient (ICC) of 0·75 was exceeded for measurements to anterior aorta (0·95), posterior aorta (0·94) and vertebra (0·96). The reliability coefficient expressed as a percentage of the mean (RC%) was lowest (better) for measurement to vertebrae (9·8%). For PFT, mean thickness was comparable for sagittal (1·74 cm) and transverse (1·76 cm) planes; ICC values were also comparable for both planes (0·98 vs. 0·98, respectively), as were RC% (7·5% vs. 7·1%, respectively). IAT assessments to the vertebra were marginally more reliable than those to other structures. While PFT assessments were equally reliable for both measurements planes, precise probe placement was easier for the sagittal plane. Based on these findings, guidelines for the reliable measurement of central adiposity using ultrasound are presented. © 2015 Stichting European Society for Clinical Investigation Journal Foundation.
Bigio Marcello, A; Gieger, T L; Jiménez, D A; Granger, L Abbigail
2015-12-01
Canine soft tissue sarcomas (STS), primary brain tumours and intranasal tumours are commonly treated with radiotherapy (RT). Given the low metastatic potential of these tumours, recommendations regarding imaging tests as staging are variable among institutions. The purpose of our study was to describe thoracic radiographic and abdominal ultrasonographic findings in dogs with these neoplasms and to investigate association of abnormal findings with alterations in recommended treatment. Medical records from 101 dogs, each having thoracic radiographs and abdominal ultrasound performed as part of their staging, were reviewed. In 98 of 101 (97%), imaging abnormalities were detected, 27% of which were further investigated with fine needle aspiration cytology or biopsy. Nine percent of the detected abnormalities were considered serious comorbidities that altered treatment recommendations, including 3 (3%) which were confirmed as synchronous primary neoplasms. These findings may influence recommendations regarding the decision to perform thoracic radiographs and abdominal ultrasound prior to initiation of RT. © 2013 John Wiley & Sons Ltd.
Ten good reasons to practice ultrasound in critical care.
Lichtenstein, Daniel; van Hooland, Simon; Elbers, Paul; Malbrain, Manu L N G
2014-01-01
Over the past decade, critical care ultrasound has gained its place in the armamentarium of monitoring tools. A greater understanding of lung, abdominal, and vascular ultrasound plus easier access to portable machines have revolutionised the bedside assessment of our ICU patients. Because ultrasound is not only a diagnostic test, but can also be seen as a component of the physical exam, it has the potential to become the stethoscope of the 21st century. Critical care ultrasound is a combination of simple protocols, with lung ultrasound being a basic application, allowing assessment of urgent diagnoses in combination with therapeutic decisions. The LUCI (Lung Ultrasound in the Critically Ill) consists of the identification of ten signs: the bat sign (pleural line); lung sliding (seashore sign); the A-lines (horizontal artefact); the quad sign and sinusoid sign indicating pleural effusion; the fractal and tissue-like sign indicating lung consolidation; the B-lines and lung rockets indicating interstitial syndromes; abolished lung sliding with the stratosphere sign suggesting pneumothorax; and the lung point indicating pneumothorax. Two more signs, the lung pulse and the dynamic air bronchogram, are used to distinguish atelectasis from pneumonia. The BLUE protocol (Bedside Lung Ultrasound in Emergency) is a fast protocol (< 3 minutes), also including a vascular (venous) analysis allowing differential diagnosis in patients with acute respiratory failure. With this protocol, it becomes possible to differentiate between pulmonary oedema, pulmonary embolism, pneumonia, chronic obstructive pulmonary disease, asthma, and pneumothorax, each showing specific ultrasound patterns and profiles. The FALLS protocol (Fluid Administration Limited by Lung Sonography) adapts the BLUE protocol to be used in patients with acute circulatory failure. It makes a sequential search for obstructive, cardiogenic, hypovolemic, and distributive shock using simple real-time echocardiography in
Sido, B; Grenacher, L; Friess, H; Büchler, M W
2005-09-01
Blunt abdominal trauma is much more frequent than penetrating abdominal trauma in Europe. As a consequence of improved quality of computed tomography, even complex liver injuries are increasingly being treated conservatively. However, missed hollow viscus injuries still remain a problem, as they considerably increase mortality in multiply injured patients. Laparoscopy decreases the rate of unnecessary laparotomies in perforating abdominal trauma and helps to diagnose injuries of solid organs and the diaphragm. However, the sensitivity in detecting hollow viscus injuries is low and the role of laparoscopy in blunt abdominal injury has not been defined. If intra-abdominal bleeding is difficult to control in hemodynamically unstable patients, damage control surgery with packing of the liver, total splenectomy, and provisional closure of hollow viscus injuries is of importance. Definitive surgical treatment follows hemodynamic stabilization and restoration of hemostasis. Injuries of the duodenum and pancreas after blunt abdominal trauma are often associated with other intra-abdominal injuries and the treatment depends on their location and severity.
Whittaker, Jackie L; Warner, Martin B; Stokes, Maria J
2009-11-01
The use of ultrasound imaging (USI) by physiotherapists to assess muscle behavior in clinical settings is increasing. However, there is relatively little evidence of whether the clinical environment is conducive to valid and reliable measurements. Accurate USI measurements depend on maintaining a relatively stationary transducer position, because motion may distort the image and lead to erroneous conclusions. This would seem particularly important during dynamic studies typical of a physiotherapy assessment. What is not known is how much transducer motion can occur before error is introduced. The aim of this study is to shed some light on this question. Eight healthy volunteers (19 to 52 y) participated. USI images were taken of the lateral abdominal wall (LAW) and bladder base (midline suprapubic) at various manually induced transducer orientations (approximately -10 to 10 degrees about 3 axes of rotation), which were quantified by a digital optical motion capture system. Measurements of transversus abdominis (TrA) thickness and bladder base position (cranial /caudal and anterior/posterior) were calculated. Repeated measures analysis of variance was performed to determine if the measurements obtained at the induced transducer orientations were statistically different (p<0.05) from an image corresponding to a reference or starting transducer orientation. Motion analysis data corresponding to measurements that did not differ from reference image measurements were summarized to provide a range of acceptable transducer motion (relative to the pelvis) for clockwise (CW)/counter-clockwise (CCW) rotation, cranial/caudal tilting, medial/lateral tilting and inward/outward displacement. There were no significant changes in TrA thickness measurements if CW/CCW transducer motion was <9 degrees and cranial/caudal or medial/lateral transducer tilting was <5 degrees . Further, there were no significant changes in measurements of bladder base position if CW/CCW transducer motion
Physics and instrumentation of ultrasound.
Lawrence, John P
2007-08-01
A thorough understanding of the physics of ultrasound waves and the instrumentation will provide the user with a better understanding of the capabilities and limitations of ultrasound equipment. The ultrasound machine combines two technologies: image production (M-mode and 2-dimensional imaging) with Doppler assessment (continuous and pulse wave as well as color-flow mapping). These distinct technologies have been combined to provide the examiner with the ability to make accurate and comprehensive diagnoses and guide therapeutic intervention.
Doppler ultrasound evaluation in preeclampsia
2013-01-01
Background Worldwide preeclampsia (PE) is the leading cause of maternal death and affects 5 to 8% of pregnant women. PE is characterized by elevated blood pressure and proteinuria. Doppler Ultrasound (US) evaluation has been considered a useful method for prediction of PE; however, there is no complete data about the most frequently altered US parameters in the pathology. The aim of this study was to evaluate the uterine, umbilical, and the middle cerebral arteries using Doppler US parameters [resistance index (RI), pulsatility index (PI), notch (N), systolic peak (SP) and their combinations] in pregnant women, in order to make a global evaluation of hemodynamic repercussion caused by the established PE. Results A total of 102 pregnant Mexican women (65 PE women and 37 normotensive women) were recruited in a cases and controls study. Blood velocity waveforms from uterine, umbilical, and middle cerebral arteries, in pregnancies from 24 to 37 weeks of gestation were recorded by trans-abdominal examination with a Toshiba Ultrasound Power Vision 6000 SSA-370A, with a 3.5 MHz convex transducer. Abnormal general Doppler US profile showed a positive association with PE [odds ratio (OR) = 2.93, 95% confidence interval (CI) = 1.2 - 7.3, P = 0.021)], and a specificity and predictive positive value of 89.2% and 88.6%, respectively. Other parameters like N presence, RI and PI of umbilical artery, as well as the PI of middle cerebral artery, showed differences between groups (P values < 0.05). Conclusion General Doppler US result, as well as N from uterine vessel, RI from umbilical artery, and PI from umbilical and middle cerebral arteries in their individual form, may be considered as tools to determine hemodynamic repercussion caused by PE. PMID:24252303
Talley, Nicholas J; Holtmann, Gerald; Nguyen, Quoc Nam; Gibson, Peter; Bampton, Peter; Veysey, Martin; Wong, James; Philcox, Stephen; Koloski, Natasha; Bunby, Lisa; Jones, Michael
2017-11-01
A previous UK study showed that 6.1% of patients with diarrhea-predominant irritable bowel syndrome (IBS-D) had evidence of severe pancreatic exocrine insufficiency (PEI), but these findings need replication. We aimed to identify the prevalence of PEI based on fecal elastase stool testing in consecutive outpatients presenting with chronic unexplained abdominal pain and/or diarrhea and/or IBS-D. Patients aged over 40 years presenting to hospital outpatient clinics from six sites within Australia with unexplained abdominal pain and/or diarrhea for at least 3 months and/or IBS-D were studied. Patients completed validated questionnaires and donated a stool sample in which elastase concentration was measured by ELISA. A concentration of < 100 mcg/g stool represented severe and < 200 mcg/g mild to moderate PEI. Patients whose fecal elastase was < 200 mcg/g underwent testing for pancreatic pathology with an endoscopic ultrasound or abdominal CT. Two hundred eighteen patients (mean age of 60 years, 29.4% male) were studied. PEI was found in 4.6% (95% CI 2.2-8.3%) (n = 10), with five patients (2.3% (95% CI 0.8-5.3%) having severe PEI. Only male sex and heavy alcohol use were significantly associated with abnormal versus normal pancreatic functioning. Of seven patients who underwent endoscopic ultrasound or CT, two had features indicative of chronic pancreatitis. One in 50 patients with IBS-D or otherwise unexplained abdominal pain or diarrhea have an abnormal fecal elastase, but unexpected pancreatic insufficiency was detected in only a minority of these. This study failed to confirm the high prevalence of PEI among patients with unexplained GI symptoms previously reported. © 2017 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
Pi, Z B; Lin, H; He, G D; Cai, Z; Xu, X Z
2015-01-01
To evaluate the efficacy of ultrasound-guided spinal nerve posterior ramus pulsed radiofrequency treatment for lower back post-herpetic neuralgia. 128 cases of lower back or anterior abdominal wall acute post-herpetic neuralgia patients were selected. They were randomly divided into two groups. Group A: oral treatment only with gabapentin + celecoxib + amitriptyline. Group B: while taking these drugs, patients were treated with radiofrequency (RF) pulses using a portable ultrasound device using the paravertebral puncture technique. In both groups, sudden outbreaks of pain were treated with immediate release 10mg morphine tablets. Visual analogue scale (VAS) was used for pain score, Pittsburgh Sleep Quality Index scale (PSQI) was used to evaluate sleep quality and morphine consumption were recorded at different time points, before and after treatment. Treatment efficiency was calculated while the occurrence of complications was documented. At each time point after treatment, VAS scores were lower, but scores in the RF group was significantly lower than those of the oral-only group. In terms of sleep quality scores and morphine consumption between the two groups, the RF group was significantly lower than the oral-only group. During the procedure no error occurred with needle penetrating the abdominal cavity, chest, offal or blood vessels. Ultrasound-guided spinal nerve posterior ramus pulsed radiofrequency treatment of lower back or anterior abdominal wall post-herpetic neuralgia proved effective by reducing morphine use in patients and led to fewer adverse reactions.
Chronic abdominal wall pain misdiagnosed as functional abdominal pain.
van Assen, Tijmen; de Jager-Kievit, Jenneke W A J; Scheltinga, Marc R; Roumen, Rudi M H
2013-01-01
The abdominal wall is often neglected as a cause of chronic abdominal pain. The aim of this study was to identify chronic abdominal wall pain syndromes, such as anterior cutaneous nerve entrapment syndrome (ACNES), in a patient population diagnosed with functional abdominal pain, including irritable bowel syndrome, using a validated 18-item questionnaire as an identification tool. In this cross-sectional analysis, 4 Dutch primary care practices employing physicians who were unaware of the existence of ACNES were selected. A total of 535 patients ≥18 years old who were registered with a functional abdominal pain diagnosis were approached when they were symptomatic to complete the questionnaire (maximum 18 points). Responders who scored at least the 10-point cutoff value (sensitivity, 0.94; specificity, 0.92) underwent a diagnostic evaluation to establish their final diagnosis. The main outcome was the presence and prevalence of ACNES in a group of symptomatic patients diagnosed with functional abdominal pain. Of 535 patients, 304 (57%) responded; 167 subjects (31%) recently reporting symptoms completed the questionnaire. Of 23 patients who scored above the 10-point cutoff value, 18 were available for a diagnostic evaluation. In half of these subjects (n = 9) functional abdominal pain (including IBS) was confirmed. However, the other 9 patients were suffering from abdominal wall pain syndrome, 6 of whom were diagnosed with ACNES (3.6% prevalence rate of symptomatic subjects; 95% confidence interval, 1.7-7.6), whereas the remaining 3 harbored a painful lipoma, an abdominal herniation, and a painful scar. A clinically relevant portion of patients previously diagnosed with functional abdominal pain syndrome in a primary care environment suffers from an abdominal wall pain syndrome such as ACNES.
Jung, Halim; Jung, Sangwoo; Joo, Sunghee; Song, Changho
2016-01-01
[Purpose] The purpose of this study was to compare changes in the mobility of the pelvic floor muscle during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. [Subjects] Thirty healthy adults participated in this study (15 men and 15 women). [Methods] All participants performed a bridge exercise and abdominal curl-up during the abdominal drawing-in maneuver, maximal expiration, and pelvic floor muscle maximal contraction. Pelvic floor mobility was evaluated as the distance from the bladder base using ultrasound. [Results] According to exercise method, bridge exercise and abdominal curl-ups led to significantly different pelvic floor mobility. The pelvic floor muscle was elevated during the abdominal drawing-in maneuver and descended during maximal expiration. Finally, pelvic floor muscle mobility was greater during abdominal curl-up than during the bridge exercise. [Conclusion] According to these results, the abdominal drawing-in maneuver induced pelvic floor muscle contraction, and pelvic floor muscle contraction was greater during the abdominal curl-up than during the bridge exercise. PMID:27065532
Evaluation of left ventricular function by bedside ultrasound in acute toxic myocarditis.
Brown, Cara; Budhram, Gavin
2013-10-01
Myocarditis can be difficult to diagnose in the Emergency Department (ED) due to the lack of classic symptoms and the wide variation in presentations. Poor cardiac contractility is a common finding in myocarditis and can be evaluated by bedside ultrasound. To demonstrate the utility of fractional shortening measurements as an estimation of left ventricular function during bedside cardiac ultrasound evaluation in the ED. A 54-year-old man presented to the ED complaining of 3 days of chest tightness, palpitations, and dyspnea, as well as persistent abdominal pain and vomiting. An electrocardiogram (ECG) showed sinus tachycardia with presumably new ST-segment elevation and signs of an incomplete right bundle branch block. A bedside echocardiogram was performed by the emergency physician that showed poor left ventricular function by endocardial fractional shortening measurements. On further questioning, the patient revealed that for the past 2 weeks he had been regularly huffing a commercially available compressed air duster. Based on these history and examination findings, the patient was given a presumptive diagnosis of toxic myocarditis. A follow-up echocardiogram approximately 7 weeks later demonstrated resolution of the left ventricular systolic dysfunction and his ECG findings normalized. Cardiac ultrasound findings of severely reduced global function measured by endocardial fractional shortening were seen in this patient and supported the diagnosis of myocarditis. Endocardial fractional shortening is a useful means of easily evaluating and documenting left ventricular function and can be performed at the bedside in the ED. Copyright © 2013 Elsevier Inc. All rights reserved.
Detection of Asymptomatic Renal Calcifications in Astronauts Using a Novel Ultrasound Protocol
NASA Technical Reports Server (NTRS)
Garcia, Kathleen; Sargsyan, Ashot; Reyes, David; Locke, James
2017-01-01
Ultrasound (US) specifically looking for asymptomatic renal calcifications that may be renal stones is typically not done in the terrestrial setting. Standard abdominal US without a renal focus may discover incidental, mineralized renal material (MRM); however punctate solid areas of MRM is less than 3 mm are usually considered subclinical. Detecting these early calcifications before they become symptomatic renal stones is critical to prevent adverse medical and mission outcomes during spaceflight.
Laparoscopy In Unexplained Abdominal Pain: Surgeon's Perspective.
Abdullah, Muhammad Tariq; Waqar, Shahzad Hussain; Zahid, Muhammad Abdul
2016-01-01
Unexplained abdominal pain is a common but difficult presenting feature faced by the clinicians. Such patients can undergo a number of investigations with failure to reach any diagnosis. The objective of this study was to evaluate the use of laparoscopy in the diagnosis and management of patients with unexplained abdominal pain. This cross-sectional study was conducted at Pakistan Institute of Medical Sciences Islamabad from January 2009 to December 2013. This study included 91 patients of unexplained abdominal pain not diagnosed by routine clinical examination and investigations. These patients were subjected to diagnostic laparoscopy for evaluation of their conditions and to confirm the diagnosis. These patients presented 43% of patients undergoing investigations for abdominal pain. Patients diagnosed with gynaecological problems were excluded to see surgeon's perspective. The findings and the outcomes of the laparoscopy were recorded and data was analyzed. Unexplained abdominal pain is common in females than in males. The most common laparoscopic findings were abdominal tuberculosis followed by appendicitis. Ninety percent patients achieved pain relief after laparoscopic intervention. Laparoscopy is both beneficial and safe in majority of patients with unexplained abdominal pain. General surgeons should acquire training and experience in laparoscopic surgery to provide maximum benefit to these difficult patients.
Griffiths, A; terHaar, G; Rivens, I; Giussani, D; Lees, C
2012-12-01
Although ultrasound is an essential investigative modality in obstetrics and gynecology, the potential for therapeutic high-intensity focused ultrasound (HIFU) (also referred to as focused ultrasound surgery, FUS) to offer an alternative to invasive surgery is less well known. The ability of HIFU to create discrete regions of tissue necrosis only in precisely targeted positions by careful placement of the focus, without the need for any surgical intervention, has made HIFU of interest to those seeking noninvasive alternatives to conventional abdominal surgery. This article reviews the current experimental and clinical experience with HIFU in obstetrics and gynecology, and outlines potential future applications in fetal medicine and the challenges faced in their development. © Georg Thieme Verlag KG Stuttgart · New York.
Prevalence of incidental pancreatic cyst on upper endoscopic ultrasound
Martínez, Belén; Martínez, Juan F.; Aparicio, José R.
2018-01-01
Background: This study aimed to determine the prevalence of incidental pancreatic cysts in patients undergoing upper endoscopic ultrasound without a known pancreatic abnormality. Methods: This prospective study was conducted in two hospitals in Spain and enrolled consecutive patients referred for upper endoscopic ultrasound for a condition unrelated to the pancreas. Patients with a previous pancreatic anomaly, history of acute or chronic pancreatitis, evidence of acute pancreatitis, previous upper gastrointestinal surgery, or chronic abdominal pain suggestive of pancreatic origin were excluded. Univariate logistic regression was performed to evaluate individual covariates and the incidental pancreatic cyst risk. Results: A total of 298 patients were included, of whom 64 had pancreatic cysts (21.5%; 16.9-26.6%). The mean size of the cysts was 6.3±3.7 (range 3-25) mm. Six cysts (2%) were >10 mm and 16 (5.4%) were compatible with branch duct intraductal papillary mucinous neoplasm. The pancreatic cyst prevalence was similar in the two hospitals and increased significantly with age. Conclusion: The prevalence of incidental pancreatic cysts during endoscopic ultrasound was very high in our study population. PMID:29333072
Reboul, Q; Delabaere, A; Luo, Z C; Nuyt, A-M; Wu, Y; Chauleur, C; Fraser, W; Audibert, F
2017-03-01
To compare third-trimester ultrasound screening methods to predict small-for-gestational age (SGA), and to evaluate the impact of the ultrasound-delivery interval on screening performance. In this prospective study, data were collected from a multicenter singleton cohort study investigating the links between various exposures during pregnancy with birth outcome and later health in children. We included women, recruited in the first trimester, who had complete outcome data and had undergone third-trimester ultrasound examination. Demographic, clinical and biological variables were also collected from both parents. We compared prediction of delivery of a SGA neonate (birth weight < 10 th percentile) by the following methods: abdominal circumference (AC) Z-score based on Hadlock curves (Hadlock AC), on INTERGROWTH-21 st Project curves (Intergrowth AC) and on Salomon curves (Salomon AC); estimated fetal weight (EFW) Z-score based on Hadlock curves (Hadlock EFW) and on customized curves from Gardosi (Gardosi EFW); and fetal growth velocity based on change in AC between second and third trimesters (FGVAC). We also assessed the following ultrasound-delivery intervals: ≤ 4 weeks, ≤ 6 weeks and ≤ 10 weeks. Third-trimester ultrasound was performed in 1805 patients with complete outcome data, of whom 158 (8.8%) delivered a SGA neonate. Ultrasound examination was at a median gestational age of 32 (interquartile range, 31-33) weeks. The ultrasound-delivery interval was ≤ 4 weeks in 17.2% of cases, ≤ 6 weeks in 48.1% of cases and ≤ 10 weeks in 97.3% of cases. Areas under the receiver-operating characteristics curve (AUC) were 0.772 for Salomon AC, 0.768 for Hadlock EFW, 0.766 for Hadlock AC, 0.765 for Intergrowth AC, 0.708 for Gardosi EFW and 0.674 for FGVAC (all P < 0.0001). The screening method with the highest AUC for an ultrasound-delivery interval ≤ 4 weeks was Salomon AC (AUC, 0.856), ≤ 6 weeks was Hadlock AC (AUC, 0.824) and ≤ 10 weeks was Salomon AC
Maintenance of Pain in Children with Functional Abdominal Pain
Czyzewski, Danita I.; Self, Mariella M.; Williams, Amy E.; Weidler, Erica M.; Blatz, Allison M.; Shulman, Robert J.
2015-01-01
Objectives A significant proportion of children with functional abdominal pain develop chronic pain. Identifying clinical characteristics predicting pain persistence is important in targeting interventions. We examined whether child anxiety and/or pain-stooling relations were related to maintenance of abdominal pain frequency and compared the predictive value of three methods for assessing pain-stooling relations (i.e., diary, parent report, child report). Methods Seventy-six children (7–10-years-old at baseline) who presented for medical treatment of functional abdominal pain were followed up 18–24 months later. Baseline anxiety and abdominal pain-stooling relations based on pain and stooling diaries and child- and parent-questionnaires were examined in relationship to the persistence of abdominal pain frequency. Results Children’s baseline anxiety was not related to persistence of pain frequency. However, children who displayed irritable bowel syndrome (IBS) symptoms at baseline maintained pain frequency at follow-up, whereas in children in whom there was no relationship between pain and stooling, pain frequency decreased. Pain and stool diaries and parent report of pain-stooling relations were predictive of pain persistence but child-report questionnaires were not. Conclusions The presence of IBS symptoms in school age children with functional abdominal pain appears to predict persistence of abdominal pain over time, while anxiety does not. Prospective pain and stooling diaries and parent report of IBS symptoms were predictors of pain maintenance, but child report of symptoms was not. PMID:26301615
Sports Ultrasound: Applications Beyond the Musculoskeletal System.
Finnoff, Jonathan T; Ray, Jeremiah; Corrado, Gianmichael; Kerkhof, Deanna; Hill, John
2016-09-01
Traditionally, ultrasound has been used to evaluate musculoskeletal injuries in athletes; however, ultrasound applications extend well beyond musculoskeletal conditions, many of which are pertinent to athletes. Articles were identified in PubMed using the search terms ultrasound, echocardiogram, preparticipation physical examination, glycogen, focused assessment with sonography of trauma, optic nerve, and vocal cord dysfunction. No date restrictions were placed on the literature search. Clinical review. Level 4. Several potential applications of nonmusculoskeletal ultrasound in sports medicine are presented, including extended Focused Assessment with Sonography for Trauma (eFAST), limited echocardiographic screening during preparticipation physical examinations, assessment of muscle glycogen stores, optic nerve sheath diameter measurements in athletes with increased intracranial pressure, and assessment of vocal cord dysfunction in athletes. Ultrasound can potentially be used to assist athletes with monitoring their muscle glycogen stores and the diagnosis of multiple nonmusculoskeletal conditions within sports medicine. © 2016 The Author(s).
Santos, Susana; Gaillard, Romy; Oliveira, Andreia; Barros, Henrique; Abrahamse-Berkeveld, Marieke; van der Beek, Eline M; Hofman, Albert; Jaddoe, Vincent WV
2017-01-01
Background Skinfold thickness enables the measurement of overall and regional subcutaneous fatness in infancy and may be associated with total and abdominal body fat in later childhood. We examined the associations of subcutaneous fat in infancy with total and abdominal fat at school-age. Methods In a population-based prospective cohort study among 821 children, we calculated total subcutaneous fat (sum of biceps, triceps, suprailiacal and subscapular skinfold thicknesses) and central-to-total subcutaneous fat ratio (sum of suprailiacal and subscapular skinfold thicknesses/total subcutaneous fat) at 1.5 and 24 months. At 6 years, we measured fat mass index (total fat/height3), central-to-total fat ratio (trunk fat/total fat) and android-to-gynoid fat ratio (android fat/gynoid fat) by dual-energy X-ray absorptiometry and preperitoneal fat mass area by abdominal ultrasound. Results Central-to-total subcutaneous fat ratio at 1.5 months was positively associated with fat mass index and central-to-total fat ratio at 6 years, whereas both total and central-to-total subcutaneous fat ratio at 24 months were positively associated with all childhood adiposity measures (p<0.05). A 1-standard-deviation scores higher total subcutaneous fat at 24 months was associated with an increased risk of childhood overweight (Odds Ratio 1.70 [95% Confidence Interval 1.36, 2.12]). These associations were weaker than those for body mass index and stronger among girls than boys. Conclusions Subcutaneous fat in infancy is positively associated with total and abdominal fat at school-age. Our results also suggest that skinfold thicknesses add little value to estimate later body fat, as compared to body mass index. PMID:27225335
Santos, Susana; Gaillard, Romy; Oliveira, Andreia; Barros, Henrique; Abrahamse-Berkeveld, Marieke; van der Beek, Eline M; Hofman, Albert; Jaddoe, Vincent W V
2016-09-01
Skinfold thickness enables the measurement of overall and regional subcutaneous fatness in infancy and may be associated with total and abdominal body fat in later childhood. We examined the associations of subcutaneous fat in infancy with total and abdominal fat at school-age. In a population-based prospective cohort study among 821 children, we calculated total subcutaneous fat (sum of biceps, triceps, suprailiacal, and subscapular skinfold thicknesses) and central-to-total subcutaneous fat ratio (sum of suprailiacal and subscapular skinfold thicknesses/total subcutaneous fat) at 1.5 and 24 months. At 6 years, we measured fat mass index (total fat/height(3) ), central-to-total fat ratio (trunk fat/total fat), and android-to-gynoid fat ratio (android fat/gynoid fat) by dual-energy X-ray absorptiometry and preperitoneal fat mass area by abdominal ultrasound. Central-to-total subcutaneous fat ratio at 1.5 months was positively associated with fat mass index and central-to-total fat ratio at 6 years, whereas both total and central-to-total subcutaneous fat ratio at 24 months were positively associated with all childhood adiposity measures. A 1-standard-deviation scores higher total subcutaneous fat at 24 months was associated with an increased risk of childhood overweight (odds ratio 1.70, 95% confidence interval 1.36, 2.12). These associations were weaker than those for body mass index and stronger among girls than boys. Subcutaneous fat in infancy is positively associated with total and abdominal fat at school-age. Our results also suggest that skinfold thicknesses add little value to estimate later body fat, as compared with body mass index. © 2016 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Cachard, Christian; Basset, Olivier
While the use of contrast agents in other imaging modalities (X ray, MRI, PET, …) has been routinely accepted for many years, the development and commercialization of contrast agents designed specifically for ultrasound imaging has occurred only very recently. As in the other imaging modalities, the injection of contrast agents during an ultrasound examination is intended to facilitate the detection and diagnosis of specific pathologies. Contrast agents efficiency is based on the backscattering of ultrasound by microbubbles. These microparticules are intravenously injected in the blood flow. After an introduction and generalities on ultrasound contrast agents (UCA) the microbubble physics in an acoustic field will be developed. Second, physics characteristics of contrast agents will be compared (bubbles with or without shell, gas nature, size distribution). Influence of acoustic pressure on the behaviour of the microparticules (linear, non linear and destruction) will be discussed. Finally, a review of specific imaging adapted to contrast agent properties as harmonic imaging, pulse inversion imaging will be presented.
Firoozabadi, Razieh Dehghani; Karimi Zarchi, Mojgan; Mansurian, Hamid Reza; Moghadam, Bita Rafiei; Teimoori, Soraya; Naseri, Ali
2011-01-01
Because benign and malignant cervical and ovarian masses occur with different percentages in different age groups, the importance of primary diagnosis and selection of a suitable surgical procedure is underlined. Diagnosis of pelvic masses is carried out using ultrasound, physical examination, CT scan and MRI. The objective of this study is to evaluate the diagnostic value of CT scan in pelvic masses in comparison with physical examination-ultrasound based on pathology of the lesion in patients undergoing laparotomic surgery. This analytic-descriptive study focused on age, sonographic findings, physical examinations, CT scan and pathological findings in 139 patients with pelvic mass, gathered with questionnaires and statistically analayzed using the SPSS software programme. Of 139 patients with pelvic mass (patients aged from 17 to 75 years old), 62 (44%) cases were diagnosed as benign and 77 (55.4%) as malignant; among them malignant tratoma serocyst adenocarsinoma with 33 (23.7%) cases and benign myoma with 21 (15.2%) cases comprised the most frequent cases. The sensitivity and specificity of sonography-physical examination were 51.9% and 87.9% respectively and the sensitivity and specificity of CT scan images were 79.2% and 91.6% respectively. It was shown that CT scan images were more consistant with pathological findings in predicting appropriate surgical procedures than do sonography-physical examinations. The sensitivity of CT scan is far higher than that of sonography-physical examination in the diagnosis of pelvic mass malignancy.
Orfila, C; Goffinet, F; Goudable, C; Eche, J P; Ton That, H; Manuel, Y; Suc, J M
1988-01-01
Abdominal fat tissue aspiration was used in 22 long-term hemodialysis patients (5-17 years). Fourteen of these patients had carpal tunnel syndrome and amyloid deposits of beta 2-microglobulin in the synovium. One patient had a spontaneous rupture of the spleen with amyloid deposits in spleen vessels. Seven other patients presented carpal tunnel syndrome and/or articular pains, and radiological lytic lesions in bone, strongly suggesting an amyloid origin. As a control group, in 22 patients with biopsy-proven amyloidosis, abdominal fat tissue aspirates were performed and were studied under the same conditions: by light microscopy these tissues were stained with Congo red and examined with a polarizing microscope; these specimens were also studied by electron microscopy. In all hemodialyzed patients, no amyloid deposit was present in fat tissue with Congo red staining and by electron microscopy. On the contrary, amyloid was observed in 17 of 22 cases in other types of amyloidosis. It seems that this method which has been proved to be simple and sensitive for the diagnosis of systemic amyloidosis is not a good marker for the presence of amyloid in long-term hemodialysis patients.
Open versus endovascular stent graft repair for abdominal aortic aneurysms: an historical view.
Rutherford, Robert B
2012-03-01
Development of endovascular abdominal aortic aneurysms repair (EVAR), now in its 4th decade, has involved at least 16 different devices, not counting major modifications of some, only 4 of which have emerged from clinical trials and gained US Food and Drug Administration approval. The main impetus behind EVAR has been its potential for significantly reducing procedural mortality and morbidity, but it was also expected to speed recovery and reduce costs through decreased use of hospital resources. At the outset, EVAR was touted as a better alternative to OPEN in high-risk patients with large abdominal aortic aneurysms, and to "watchful waiting" (periodic ultrasound surveillance) for those with small abdominal aortic aneurysms. This new technology has evoked a mixed response with enthusiasts and detractors debating its pros and cons. Bias and conflict of interest exist on both sides. This review will attempt to present a balanced review of the development and current status of this controversial competition between EVAR and OPEN, comparing them in terms of the following key considerations: mortality and morbidity, complications, failure modes and durability, and costs. Copyright © 2012 Elsevier Inc. All rights reserved.
Abdominal rectus muscle pyomyositis: Report of a case and review of the literature
Fountoukis, Tilemachos; Tsatsanidis, Nikolaos; Tilkeridou, Maria; Konstantinou, Ioannis; Fytas, Pantelis; Skandalos, Ioannis
2018-01-01
Pyomyositis is an uncommon primary bacterial infection of skeletal muscles, usually caused by Staphylococcus aureus. Predisposing factors for pyomyositis include immunodeficiency, trauma, injection drug use, concurrent infection and malnutrition. The diagnosis, staging of the disease and differential diagnosis are established by ultrasound, CT and MRI. Treatment involves surgical drainage and antibiotic therapy. We report a case of abdominal rectus muscle pyomyositis, which constitutes, as far as we know, the second reported in bibliography, while Prevotella disiens is firstly reported as causative agent. PMID:29721242
Point-of-care ultrasound leads to diagnostic shifts in patients with undifferentiated hypotension.
Shokoohi, Hamid; Boniface, Keith S; Zaragoza, Michelle; Pourmand, Ali; Earls, James P
2017-12-01
To assess the impact of an ultrasound hypotension protocol in identifying life-threatening diagnoses that were missed in the initial evaluation of patients with hypotension and shock. A subset of cases from a previously published prospective study of hypotensive patients who presented at the Emergency Department in a single, academic tertiary care hospital is described. An ultrasound-trained emergency physician performed an ultrasound on each patient using a standardized hypotension protocol. In each case, the differential diagnosis and management plan was solicited from the treating physician immediately before and after the ultrasound. This is a case series of patients with missed diagnoses in whom ultrasound led to a dramatic shift in diagnosis and management by detecting life threatening pathologies. Following a published prospective study of the effect on an ultrasound protocol in 118 hypotensive patients, we identified a series of cases that ultrasound protocol unexpectedly determined serious life threatening diagnoses such as Takotsubo cardiomyopathy, pulmonary embolism, pericardial effusion with tamponade physiology, abdominal aortic aneurysm and perforated viscus resulting in proper diagnoses and management. These hypotensive patients had completely unsuspected but critical diagnoses explaining their hypotension, who in every case had their management altered to target the newly identified life-threatening condition. A hypotension protocol is an optimal use of ultrasound that exemplifies "right time, right place", and impacts decision-making at the bedside. In cases with undifferentiated hypotension, ultrasound is often the most readily available option to ensure that the most immediate life-threatening conditions are quickly identified and addressed in the order of their risk potential. Copyright © 2017 Elsevier Inc. All rights reserved.
Suzuki, Shinichi; Yamashita, Shunichi; Fukushima, Toshihiko; Nakano, Keiichi; Midorikawa, Sanae; Ohtsuru, Akira; Yasumura, Seiji; Hosoya, Mitsunori; Kamiya, Kenji; Shimura, Hiroki; Suzuki, Satoru; Nakamura, Izumi; Abe, Masafumi
2016-01-01
After the Fukushima nuclear power plant accident on March 11, 2011, the public of Japan became particularly concerned about the possibility of an increased risk of childhood thyroid cancer, similar to what was observed after the Chernobyl's accident. Due to serious public health perception, there was an urgency to evaluate the baseline levels of childhood thyroid status in Fukushima prefecture. Therefore we have commenced a thyroid ultrasound examination (TUE) survey of the approximately 360,000 pediatric inhabitants (0 to 18 years of age) who lived in Fukushima at the time of the accident in October 2011. The subjects were divided into three categories according to the standardized diagnostic criteria of ultrasound findings. Category A contained the subjects whose TUE findings were intact or benign. Category B were recommended a confirmatory TUE. Category C was recommended an immediate confirmatory TUE. The survey of 40,302 subjects in the first year was completed in March, 2013. There were 40,097 (99.5%), 205 (0.50%) and 0 subjects in categories A, B and C, respectively. Of the 82 category B subjects who underwent fine needle aspiration cytology (FNAC), 12 were diagnosed with a malignant tumor or were suspected to have malignancy. The 12 subjects received thyroid surgery and 11 thyroid cancers and one benign nodule were confirmed histologically after surgery. This is the first large-scaled TUE survey to employ sophisticated ultrasound screening and aim to evaluate the baseline frequency of childhood thyroid nodules and cysts. The results will become the golden standard of future comparative TUE in Fukushima, Japan.
[Desmoid tumor of the abdominal wall].
Jørgensen, H; Henriksen, L O; Medgyesi, S; Waever, E
1994-02-07
Four cases of muscle-aponeurotic fibroadenomatosis (desmoid) of the abdominal wall are reported. The etiological factors, the recurrence rate, the treatment and the pre- and postoperative examinations are discussed.
Impact of ultrasound video transfer on the practice of ultrasound
NASA Astrophysics Data System (ADS)
Duerinckx, Andre J.; Hayrapetian, Alek S.; Grant, Edward G.; Valentino, Daniel J.; Rahbar, Darius; Kiszonas, Mike; Franco, Ricky; Melany, Michelle; Narin, Sherelle L.; Ragavendra, Nagesh
1996-05-01
Sonography can be highly dependent on real-time imaging and as such is highly physician intensive. Such situations arise mostly during complicated ultrasound radiology studies or echocardiology examinations. Under those circumstances it would be of benefit to transmit real-time images beyond the immediate area of the ultrasound laboratory when a physician is not on location. We undertook this study to determine if both static and dynamic image transfer to remote locations might be accomplished using an ultrafast ATM network and PACS. Image management of the local image files was performed by a commercial PACS from AGFA corporation. The local network was Ethernet based, and the global network was based on Asynchronous Transfer Mode (ATM, rates up to 100 Mbits/sec). Real-time image transfer involved two teaching hospitals, one of which had 2 separate ultrasound facilities. Radiologists consulted with technologists via telephone while the examinations were being performed. The applications of ATM network providing real time video for ultrasound imaging in a clinical environment and its potential impact on health delivery and clinical teaching. This technology increased technologist and physician productivity due to the elimination of commute time for physicians and waiting time for technologists and patients. Physician confidence in diagnosis increased compared to reviewing static images alone. This system provided instant access for radiologists to real-time scans from remote sites. Image quality and frame rate were equivalent to the original. The system increased productivity by allowing physicians to monitor studies at multiple sites simultaneously.
Ultrasound diagnosis of penile fracture.
Nomura, Jason T; Sierzenski, Paul R
2010-04-01
Rupture of the corpus cavernosum, penile fracture, is an uncommon occurrence. Diagnosis is straightforward when classical historical and physical examination findings are present. However, atypical presentations can make the diagnosis difficult. Review the literature supporting use of ultrasound for the diagnosis of penile fracture. Review of the ultrasonographic findings in patients with penile fracture. A 32-year-old man presented with penile ecchymosis after sex but lacking several historical and physical examination elements for a diagnosis of penile fracture. Ultrasound performed by the treating physician revealed rupture of the tunica albuginea and presence of a hematoma, leading to a diagnosis of penile fracture. Ultrasound is a simple, efficient, and non-invasive imaging method to assist in the diagnosis of penile fracture. Copyright 2010 Elsevier Inc. All rights reserved.
Hides, Julie A; Belavý, Daniel L; Cassar, Lana; Williams, Michelle; Wilson, Stephen J; Richardson, Carolyn A
2009-03-01
An important aspect of neuromuscular control at the lumbo-pelvic region is stabilization. Subjects with low back pain (LBP) have been shown to exhibit impairments in motor control of key muscles which contribute to stabilization of the lumbo-pelvic region. However, a test of automatic recruitment that relates to function has been lacking. A previous study used ultrasound imaging to show that healthy subjects automatically recruited the transversus abdominis (TrA) and internal oblique (IO) muscles in response to a simulated weight-bearing task. This task has not been investigated in subjects with LBP. The aim of this study was to compare the automatic recruitment of the abdominal muscles among subjects with and without LBP in response to the simulated weight-bearing task. Twenty subjects with and without LBP were tested. Real-time ultrasound imaging was used to assess changes in thickness of the TrA and internal oblique IO muscles as well as lateral movement ("slide") of the anterior fascial insertion of the TrA muscle. Results showed that subjects with LBP showed significantly less shortening of the TrA muscle (P < 0.0001) and greater increases in thickness of the IO muscle (P = 0.002) with the simulated weight-bearing task. There was no significant difference between groups for changes in TrA muscle thickness (P = 0.055). This study provides evidence of changes in motor control of the abdominal muscles in subjects with LBP. This test may provide a functionally relevant and non-invasive method to investigate the automatic recruitment of the abdominal muscles in people with and without LBP.
Ishizaki, Mirian Naomi; Imbeloni, Aline Amaral; Muniz, José Augusto Pereira Carneiro; Scalercio, Sarah Raphaella Rocha de Azevedo; Benigno, Raimundo Nonato Moraes; Pereira, Washington Luiz Assunção; Cunha Lacreta Junior, Antonio Carlos
2010-10-29
This study reports a case of parasitism by Dioctophyma renale (Goeze, 1762) encysted in the abdominal cavity of a capuchin monkey (Cebus apella) coming from the Centro Nacional de Primatas, Brazil. The animal was sent to the Veterinary Clinic sector with an increase in abdominal volume and no occurrence of any other clinical signs. Upon palpation, a movable circular mass with a diameter of approximately 10 cm was found. Urinalysis, complete blood count and serum biochemistry were performed without revealing any alterations. The animal was then submitted to an abdominal ultrasound exam. The cyst was punctured and a surgical removal procedure was performed, revealing a brownish-colored cylindrical structure that was already deteriorated, making it impossible to perform morphological analysis and classification. In the sediment of the liquid found, eggs were encountered that had morphological characteristics compatible with D. renale. The objective of this paper is to report the first case of parasitism by D. renale in C. apella (Linnaeus, 1758). Copyright © 2010 Elsevier B.V. All rights reserved.
Paediatric abdominal tuberculosis in developed countries: case series and literature review.
Delisle, Megan; Seguin, Jade; Zeilinski, David; Moore, Dorothy L
2016-03-01
To provide an insight into the presentation, diagnosis and management of paediatric abdominal tuberculosis (TB) in developed countries. The records of all children at the Montreal Children's Hospital (MCH) admitted with abdominal TB between 1990 and 2014 were reviewed. An automated and manual literature search from 1946 to 2014 was performed. (1) CASE SERIES: six cases were identified at the MCH. All were male between 5 and 17 years of age. All were from populations known to have high rates of TB (aboriginal, immigrant). Three underwent major surgical interventions and three underwent ultrasound (US) or CT aspiration or biopsy for diagnosis. (2) LITERATURE REVIEW: 29 male (64%) and 16 female subjects (36%) aged between 14 months and 18 years were identified, including the MCH patients. All patients except one were from populations with a high incidence of TB. Most presented with a positive tuberculin skin test (90%), abdominal pain (76%), fever (71%) and weight loss (68%). On imaging, 22 (49%) were classified with gastrointestinal TB with colonic wall irregularity (41%) and 19 (42%) with peritoneal TB with ascites (68%). A positive culture was obtained in 33 (73%) patients. Three cases used CT- or US-guided aspiration or biopsy to obtain tissue samples. A surgical intervention was performed in 34 (76%) children; 13 (38%) of these were for diagnosis. Diagnosis based on clinical features (abdominal pain, fever and weight loss) and CT- or US-guided aspiration or biopsy may encourage physicians to adopt a more conservative approach to abdominal TB. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Management of intra-abdominal hypertension and abdominal compartment syndrome: a review
2014-01-01
Patients in the intensive care unit (ICU) are at risk of developing of intra abdominal hypertension (IAH) and abdominal compartment syndrome (ACS). Aim: This review seeks to define IAH and ACS, identify the aetiology and presentation of IAH and ACS, identify IAP measurement techniques, identify current management and discuss the implications of IAH and ACS for nursing practice. A search of the electronic databases was supervised by a health librarian. The electronic data bases Cumulative Index of Nursing and Allied Health Literature (CINAHL); Medline, EMBASE, and the World Wide Web was undertaken from 1996- January 2011 using MeSH and key words which included but not limited to: abdominal compartment syndrome, intra -abdominal hypertension, intra-abdominal pressure in adult populations met the search criteria and were reviewed by three authors using a critical appraisal tool. Data derived from the retrieved material are discussed under the following themes: (1) etiology of intra-abdominal hypertension; (2) strategies for measuring intra-abdominal pressure (3) the manifestation of abdominal compartment syndrome; and (4) the importance of nursing assessment, observation and interventions. Intra-abdominal pressure (IAP) and abdominal compartment syndrome (ACS) have the potential to alter organ perfusion and compromise organ function. PMID:24499574
Chanel, Laure-Anais; Nageotte, Florent; Vappou, Jonathan; Luo, Jianwen; Cuvillon, Loic; de Mathelin, Michel
2015-01-01
High Intensity Focused Ultrasound (HIFU) therapy is a very promising method for ablation of solid tumors. However, intra-abdominal organ motion, principally due to breathing, is a substantial limitation that results in incorrect tumor targeting. The objective of this work is to develop an all-in-one robotized HIFU system that can compensate motion in real-time during HIFU treatment. To this end, an ultrasound visual servoing scheme working at 20 Hz was designed. It relies on the motion estimation by using a fast ultrasonic speckle tracking algorithm and on the use of an interleaved imaging/HIFU sonication sequence for avoiding ultrasonic wave interferences. The robotized HIFU system was tested on a sample of chicken breast undergoing a vertical sinusoidal motion at 0.25 Hz. Sonications with and without motion compensation were performed in order to assess the effect of motion compensation on thermal lesions induced by HIFU. Motion was reduced by more than 80% thanks to this ultrasonic visual servoing system.
New scoring system for intra-abdominal injury diagnosis after blunt trauma.
Shojaee, Majid; Faridaalaee, Gholamreza; Yousefifard, Mahmoud; Yaseri, Mehdi; Arhami Dolatabadi, Ali; Sabzghabaei, Anita; Malekirastekenari, Ali
2014-01-01
An accurate scoring system for intra-abdominal injury (IAI) based on clinical manifestation and examination may decrease unnecessary CT scans, save time, and reduce healthcare cost. This study is designed to provide a new scoring system for a better diagnosis of IAI after blunt trauma. This prospective observational study was performed from April 2011 to October 2012 on patients aged above 18 years and suspected with blunt abdominal trauma (BAT) admitted to the emergency department (ED) of Imam Hussein Hospital and Shohadaye Hafte Tir Hospital. All patients were assessed and treated based on Advanced Trauma Life Support and ED protocol. Diagnosis was done according to CT scan findings, which was considered as the gold standard. Data were gathered based on patient's history, physical exam, ultrasound and CT scan findings by a general practitioner who was not blind to this study. Chi-square test and logistic regression were done. Factors with significant relationship with CT scan were imported in multivariate regression models, where a coefficient (β) was given based on the contribution of each of them. Scoring system was developed based on the obtained total β of each factor. Altogether 261 patients (80.1% male) were enrolled (48 cases of IAI). A 24-point blunt abdominal trauma scoring system (BATSS) was developed. Patients were divided into three groups including low (score<8), moderate (8≤score<12) and high risk (score≥12). In high risk group immediate laparotomy should be done, moderate group needs further assessments, and low risk group should be kept under observation. Low risk patients did not show positive CT-scans (specificity 100%). Conversely, all high risk patients had positive CT-scan findings (sensitivity 100%). The receiver operating characteristic curve indicated a close relationship between the results of CT scan and BATSS (sensitivity=99.3%). The present scoring system furnishes a high precision and reproducible diagnostic tool for BAT
[Point-of-care ultrasound in Spanish paediatric intensive care units].
González Cortés, Rafael; Renter Valdovinos, Luis; Coca Pérez, Ana; Vázquez Martínez, José Luis
2017-06-01
Point-of-care (bedside) ultrasound is being increasingly used by paediatricians who treat critically ill children. The aim of this study is to describe its availability, use, and specific training in Paediatric Intensive Care Units in Spain. A descriptive, cross-sectional, multicentre study was performed using an online survey. Of a total of 51 PICUs identified in our country, 64.7% responded to the survey. Just over half (53.1%) have their own ultrasound machine, 25% share it, with other units with the usual location in the PICU, and 21.9% share it, but it is usually located outside the PICU. Ultrasound machine availability was not related to size, care complexity, or number PICU admissions. The ultrasound was used daily in 35% of the units, and was associated with location of the machine in the PICU (P=.026), the existence of a transplant program (P=.009), availability of ECMO (P=.006), and number of admissions (P=.015). 45.5% of PICUs has less than 50% of the medical staff specifically trained in bedside ultrasound, and 18.2% have all their medical staff trained. The presence of more than 50% of medical staff trained was associated with a higher rate of daily use (P=.033), and with specific use to evaluate cardiac function (P=.033), intravascular volume estimation (P=.004), or the presence of intra-abdominal collections (P=.021). Bedside ultrasound is frequently available in Spanish PICUs. Specific training is still variable, but it should serve to enhance its implementation. Copyright © 2016 Asociación Española de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.
Medical evacuation for unrecognized abdominal wall pain: a case series.
Msonda, Hapu T; Laczek, Jeffrey T
2015-05-01
Chronic abdominal pain is a frequently encountered complaint in the primary care setting. The abdominal wall is the etiology of this pain in 10 to 30% of all cases of chronic abdominal pain. Abdominal cutaneous nerve entrapment at the lateral border of the rectus abdominis muscle has been attributed as a cause of this pain. In the military health care system, patients with unexplained abdominal pain are often transferred to military treatment facilities via the Military Medical Evacuation (MEDEVAC) system. We present two cases of patients who transferred via MEDEVAC to our facility for evaluation and treatment of chronic abdominal pain. Both patients had previously undergone extensive laboratory evaluation, imaging, and invasive procedures, such as esophagogastroduodenoscopy before transfer. Upon arrival, history and physical examinations suggested an abdominal wall source to their pain, and both patients experienced alleviation of their abdominal wall pain with lidocaine and corticosteroid injection. This case series highlights the need for military physicians to be aware of abdominal wall pain. Early diagnosis of abdominal cutaneous nerve entrapment syndrome by eliciting Carnett's sign will limit symptom chronicity, avoid unnecessary testing, and even prevent medical evacuation. Reprint & Copyright © 2015 Association of Military Surgeons of the U.S.
Nightingale, Kathryn R.; Church, Charles C.; Harris, Gerald; Wear, Keith A.; Bailey, Michael R.; Carson, Paul L.; Jiang, Hui; Sandstrom, Kurt L.; Szabo, Thomas L.; Ziskin, Marvin C.
2016-01-01
The mechanical index (MI) has been used by the US Food and Drug Administration (FDA) since 1992 for regulatory decisions regarding the acoustic output of diagnostic ultrasound equipment. Its formula is based on predictions of acoustic cavitation under specific conditions. Since its implementation over 2 decades ago, new imaging modes have been developed that employ unique beam sequences exploiting higher-order acoustic phenomena, and, concurrently, studies of the bioeffects of ultrasound under a range of imaging scenarios have been conducted. In 2012, the American Institute of Ultrasound in Medicine Technical Standards Committee convened a working group of its Output Standards Subcommittee to examine and report on the potential risks and benefits of the use of conditionally increased acoustic pressures (CIP) under specific diagnostic imaging scenarios. The term “conditionally” is included to indicate that CIP would be considered on a per-patient basis for the duration required to obtain the necessary diagnostic information. This document is a result of that effort. In summary, a fundamental assumption in the MI calculation is the presence of a preexisting gas body. For tissues not known to contain preexisting gas bodies, based on theoretical predications and experimentally reported cavitation thresholds, we find this assumption to be invalid. We thus conclude that exceeding the recommended maximum MI level given in the FDA guidance could be warranted without concern for increased risk of cavitation in these tissues. However, there is limited literature assessing the potential clinical benefit of exceeding the MI guidelines in these tissues. The report proposes a 3-tiered approach for CIP that follows the model for employing elevated output in magnetic resonance imaging and concludes with summary recommendations to facilitate Institutional Review Board (IRB)-monitored clinical studies investigating CIP in specific tissues. PMID:26112617
Cow's milk allergy: color Doppler ultrasound findings in infants with hematochezia.
Epifanio, Matias; Spolidoro, Jose Vicente; Missima, Nathalia Guarienti; Soder, Ricardo Bernardi; Garcia, Pedro Celiny Ramos; Baldisserotto, Matteo
2013-01-01
ultrasound (US) has been an important diagnostic tool to identify several causes of gastrointestinal bleeding. Infants with cow's milk allergy (CMA) may present hematochezia and the confirmation of the diagnosis can be difficult. The aim of this study is to describe grayscale and color Doppler ultrasound findings in patients with CMA. we retrospectively studied 13 infants with CMA. All infants presented severe hematochezia and abdominal pain. All underwent an US study with the diagnosis of allergic colitis. This diagnosis was based on clinical findings, recovery after infant or mother exclusion diets in the case of exclusive breastfeeding and positive oral challenge test. the mean age ranged from 1 to 6 months (mean=3.53). Seven out of 13 infants (53.8%) had grayscale and color Doppler sonographic repeated after exclusion diet. Twelve out of 13 (92,3%) showed abnormalities at US and CDUS at beginning. The positive findings suggesting colitis were thickened bowel walls and increased vascularity, especially in the descending and sigmoid colon. Colonoscopy and histopathological findings were compatible with allergic colitis. After a diet change the 13 infants recovered and their oral challenge tests were positive. Doppler US may be very useful in diagnosing secondary colitis, such as CMA, and to exclude several other abdominal diseases that can emulate this disease. Copyright © 2013 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Ultrasound-guided hydrostatic reduction of intussusception with saline: Safe and effective.
Karadağ, Çetin Ali; Abbasoğlu, Latif; Sever, Nihat; Kalyoncu, Meltem Kaba; Yıldız, Abdullah; Akın, Melih; Candan, Mustafa; Dokucu, Ali İhsan
2015-09-01
The study was undertaken to assess the efficacy of ultrasound-guided saline enema in reducing intussusception and to determine the role of age and duration of symptoms on this event. The case records of patients who were treated for intussusception at our institutions over the past 10 years were retrospectively analyzed. A total of 419 patients were treated for intussusception and 375 of them were included into the study. Patients were excluded if they had symptoms and signs of acute abdominal disease and required surgery as an initial treatment. Hydrostatic reduction was successful in 313 of the 375 patients (83.46%). The procedure-related complication rate was nil. There were 29 episodes of recurrences in 23 patients, and recurrence rates did not differ between patients who responded to hydrostatic reduction and those who required surgery. Younger age [median (range); 11 months (3-108 months) vs. 20 months (1-180 months); p<0.05], rectal bleeding (p<0.01) and long duration of symptoms [mean (range); 1.95 days (1-7 days) vs. 1.44 days (1-10 days); p<0.01] were significantly associated with failed hydrostatic reduction. Ultrasound-guided hydrostatic reduction is an easy, safe and effective method for the treatment of intussusception in the absence of acute abdominal findings. Copyright © 2015 Elsevier Inc. All rights reserved.
Current Trends in the Management of Abdominal Aortic Aneurysms
Harris, K.A.; Ameli, F. Michael; Louis, E.L. St.
1987-01-01
The treatment of abdominal aortic aneurysm has undergone dramatic changes over the last three decades. More sophisticated diagnostic techniques have allowed early elective repair to be carried out. Improvement has resulted in both morbidity and mortality rates. Investigations such as ultrasound, computerized tomographic scanning and arteriography allow easy confirmation of the diagnosis of aortic aneurysms and permit a better assessment of the extent prior to surgical intervention. Improvement in the pre-operative management, particularly in relation to cardiac, renal, and pulmonary disease, has led to greatly improved results. The most important change in surgical technique has been repair of the aneurysm rather than resection. Combined with better post-operative intensive care units, this development has contributed to the improved morbidity and mortality rates. Although the complication rate of elective repair is low, the major cause of death remains myocardial infarction. As a result of all these improvements, indication for repair of abdominal aortic aneurysms has been extended to patients over the age of 80. Following surgical repair, most patients can be expected to return to normal lifestyles and lifespans. ImagesFigure 2Figure 3Figure 4 PMID:21263973
Novais, Rommel L R; Café, Ana Carolina C; Morais, Aisha A; Bila, Wendell C; Santos, Gilson D da S; Lopes, Carlos Alexandre de O; Belo, Vinícius S; Romano, Márcia Christina C; Lamounier, Joel A
2018-04-27
To associate intra-abdominal fat thickness measured by ultrasonography to the factors related to metabolic syndrome and to determine cutoff points of intra-abdominal fat measurement associated with a greater chance of metabolic syndrome in adolescents. This was a cross-sectional study, with 423 adolescents from public schools. Intra-abdominal fat was measured by ultrasonography. Anthropometric data were collected, and biochemical analyses were performed. Intra-abdominal fat was measured by ultrasonography, showing a statistically significant association with the diagnosis of metabolic syndrome (p=0.037), body mass index (p<0.001), elevated triglyceride levels (p=0.012), decreased plasma HDL levels (p=0.034), and increased systemic blood pressure values (p=0.023). Cutoff values of intra-abdominal fat thickness measurements were calculated by ultrasound to estimate the individuals most likely to develop metabolic syndrome. In the logistic regression models, the cutoff values that showed the highest association with metabolic syndrome in males were 4.50, 5.35, 5.46, 6.24, and 6.50cm for the ages of 14, 15, 16, 17, and 18/19 years, respectively. In the female gender, the cutoff values defined for the same age groups were 4.46, 4.55, 4.45, 4.90, and 6.46cm. In an overall analysis using the ROC curve, without gender and age stratification, the cut-off of 3.67cm showed good sensitivity, but low specificity. Ultrasonography is a useful method to estimate intra-abdominal adipose tissue in adolescents, which is associated with the main factors related to obesity and metabolic syndrome. Copyright © 2018 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Hides, J A; Lambrecht, G; Stanton, W R; Damann, V
2016-05-01
In microgravity, muscle atrophy occurs in the intrinsic muscles of the spine, with changes also observed in the abdominal muscles. Exercises are undertaken on the International Space Station and on Earth following space flight to remediate these effects. Similar effects have been seen on Earth in prolonged bed rest studies and in people with low back pain (LBP). The aim of this case report was to examine the effects of microgravity, exercise in microgravity and post-flight rehabilitation on the size of the multifidus and antero-lateral abdominal muscles. Ultrasound imaging was used to assess size of the multifidus, transversus abdominis and internal oblique muscles at four time points: pre-flight and after daily rehabilitation on day one (R + 1), day 8 (R + 8) and day 14 (R + 14) after return to Earth (following 6 months in microgravity). Exercises in microgravity maintained multifidus size at L2-L4, however, after spaceflight, size of the multifidus muscle at L5 was reduced, size of the internal oblique muscle was increased and size of transversus abdominis was reduced. Rehabilitation post-space flight resulted in hypertrophy of the multifidus muscle to pre-mission size at the L5 vertebral level and restoration of antero-lateral abdominal muscle size. Exercise in space can prevent loss of spinal intrinsic muscle size. For the multifidus muscles, effectiveness varied at different levels of the spine. Post-mission rehabilitation targeting specific motor control restored muscle balance between the antero-lateral abdominal and multifidus muscles, similar to results from intervention trials for people with LBP. A limitation of the current investigation is that only one astronaut was studied, however, the microgravity model could be valuable as predictable effects on trunk muscles can be induced and interventions evaluated. Level of Evidence Case series.
Margolis, Nathaniel E; Rosenkrantz, Andrew B; Babb, James S; Macari, Michael
2015-10-01
Our aim in this study was to evaluate the effect of the radiologist, technologist, and other examination-related factors on the frequency of recommendations for additional imaging (RAI) during sonographic (US) interpretation. We retrospectively reviewed 719 US reports from a single academic medical center for the presence of RAI. All studies had been interpreted by one of three abdominal radiologists. Examinations were performed at an outpatient radiology facility with no onsite radiologist (n = 299) or at an inpatient emergency department or hospital-based outpatient setting that had an onsite radiologist (n = 420). Possible associations between the frequency of RAI and the presence of an onsite radiologist, location of the examination, body part or region imaged, patient age, technologist performing the exam, and radiologist reading the exam were evaluated. There were significant differences between each pair of radiologists in terms of overall frequency of RAI (p < 0.001) (radiologist 1: 12.0% [22/184]; radiologist 2: 21.6% [78/361]; and radiologist 3: 45.5% [79/174]). In addition, there were statistically significant differences in the frequency of RAI among studies scanned by the 10 different US technologists (13.6%-40.0%, p = 0.03). However, other factors such as patient age, patient sex, US unit, patient location, and radiologist location were not associated with the frequency of RAI (p = 0.15-0.93). The individual radiologist and technologist influenced the frequency of RAI for US examinations, whereas other examination-related factors did not. The observed substantial variability in RAI between radiologists and technologists warrants further study, with consideration of strategies to optimize RAI within US reports. © 2015 Wiley Periodicals, Inc.
Mannion, A F; Pulkovski, N; Schenk, P; Hodges, P W; Gerber, H; Loupas, T; Gorelick, M; Sprott, H
2008-04-01
Rapid arm movements elicit anticipatory activation of the deep-lying abdominal muscles; this appears modified in back pain, but the invasive technique used for its assessment [fine-wire electromyography (EMG)] has precluded its widespread investigation. We examined whether tissue-velocity changes recorded with ultrasound (M-mode) tissue Doppler imaging (TDI) provided a viable noninvasive alternative. Fourteen healthy subjects rapidly flexed, extended, and abducted the shoulder; recordings were made of medial deltoid (MD) surface EMG and of fine-wire EMG and TDI tissue-velocity changes of the contralateral transversus abdominis, obliquus internus, and obliquus externus. Muscle onsets were determined by blinded visual analysis of EMG and TDI data. TDI could not distinguish between the relative activation of the three muscles, so in subsequent analyses only the onset of the earliest abdominal muscle activity was used. The latter occurred <50 ms after the onset of medial deltoid EMG (i.e., was feedforward) and correlated with the corresponding EMG onsets (r = 0.47, P < 0.0001). The mean difference between methods was 20 ms and was likely explained by electromechanical delay; limits of agreement were wide (-40 to +80 ms) but no greater than those typical of repeated measurements using either technique. The between-day standard error of measurement of the TDI onsets (examined in 16 further subjects) was 16 ms. TDI yielded reliable and valid measures of the earliest onset of feedforward activity within the anterolateral abdominal muscle group. The method can be used to assess muscle dysfunction in large groups of back-pain patients and may also be suitable for the noninvasive analysis of other deep-lying or small/thin muscles.
Durmuş, B; Heppe, D H M; Taal, H R; Manniesing, R; Raat, H; Hofman, A; Steegers, E A P; Gaillard, R; Jaddoe, V W V
2014-07-01
Fetal smoke exposure may influence growth and body composition later in life. We examined the associations of maternal and paternal smoking during pregnancy with total and abdominal fat distribution in school-age children. We performed a population-based prospective cohort study among 5243 children followed from early pregnancy onward in the Netherlands. Information about parental smoking was obtained by questionnaires during pregnancy. At the median age of 6.0 years (90% range: 5.7-7.4), we measured anthropometrics, total fat and android/gynoid fat ratio by dual-energy X-ray absorptiometry, and preperitoneal and subcutaneous abdominal fat were measured by ultrasound. The associations of maternal smoking during pregnancy were only present among girls (P-value for sex interaction<0.05). Compared with girls from mothers who did not smoke during pregnancy, those from mothers who smoked during the first trimester only had a higher android/gynoid fat ratio (difference 0.23 (95% confidence interval (CI): 0.09-0.37) s.d. scores (SDS). Girls from mothers who continued smoking throughout pregnancy had a higher body mass index (difference: 0.24 (95% CI: 0.14-0.35) SDS), total fat mass (difference: 0.23 (95% CI: 0.14-0.33) SDS), android/gynoid fat ratio (difference: 0.34 (95% CI: 0.22-0.46) SDS), subcutaneous abdominal fat (difference: 0.22 (95% CI: 0.11-0.33) SDS) and preperitoneal abdominal fat (difference: 0.20 (95% CI: 0.08-0.31) SDS). Similar associations with body fat distribution outcomes were observed for paternal smoking during pregnancy. Both continued maternal and paternal smoking during pregnancy may be associated with an increased risk of childhood overweight. The corresponding odds ratios were 1.19 (95% CI: 0.98-1.46) and 1.32 (1.10-1.58), respectively. Maternal and paternal smoking during pregnancy are associated with an adverse body and abdominal fat distribution and increased risk of overweight in children. Similar effects of maternal and paternal smoking
Utility of Point-of-care Ultrasound in Children With Pulmonary Tuberculosis.
Bélard, Sabine; Heuvelings, Charlotte C; Banderker, Ebrahim; Bateman, Lindy; Heller, Tom; Andronikou, Savvas; Workman, Lesley; Grobusch, Martin P; Zar, Heather J
2018-07-01
Point-of-care ultrasound (POCUS) detects extrapulmonary tuberculosis (EPTB) in HIV infected adults but has not been evaluated in children despite their higher risk of EPTB. This study's aims were to investigate feasibility of POCUS for EPTB in children, frequency of POCUS findings suggestive of EPTB and time to sonographic resolution of findings with treatment. This prospective South African cohort study enrolled children with suspected pulmonary tuberculosis (PTB). POCUS for pleural, pericardial or ascitic effusion, abdominal lymphadenopathy or splenic or hepatic microabscesses was performed and repeated at 1, 3 and 6 months of tuberculosis (TB) treatment. Prevalence of POCUS findings and their association with HIV infection was investigated in children with confirmed PTB (microbiologically proven), unconfirmed PTB (clinically diagnosed) or unlikely TB (respiratory disease that improved during follow-up without TB treatment). Of 232 children [median age 37 months (interquartile range, 18-74)], 39 (17%) were HIV infected. Children with confirmed or unconfirmed PTB had a higher prevalence of POCUS findings than children with unlikely TB [18 of 58 (31%) and 36 of 119 (30%) vs. 8 of 55 (15%); P = 0.04 and P = 0.03, respectively]. Pleural effusion [n = 30 (13%)] or abdominal lymphadenopathy [n = 28 (12%)] were the most common findings; splenic microabscesses [n = 12 (5%)] were strongly associated with confirmed PTB. Children coinfected with HIV and TB were more likely than HIV-uninfected children with TB to have abdominal lymphadenopathy (37% vs. 10%; P < 0.001) or splenic microabscesses (23% vs. 3%; P < 0.001]. Most ultrasound findings were resolved by 3 months with appropriate TB treatment. POCUS for EPTB in children with PTB is feasible. The high prevalence of findings suggests that POCUS can contribute to timely diagnosis of childhood TB and to monitoring treatment response.
Shek, Samantha Y N; Yeung, Chi K; Chan, Johnny C Y; Chan, Henry H L
2016-02-01
Several studies have been published on the first generation non-thermal focused ultrasound with an average improvement of 0-3.95 cm reported. We aim to investigate the efficacy of the second-generation non-thermal focused ultrasound device with a combined radiofrequency hand piece. With the addition of radiofrequency energy, the temperature of the adipose tissue is raised before focused ultrasound is applied. This facilitates the mechanical disruption of fat cells by focused ultrasound. Twenty subjects were recruited and underwent three treatments biweekly. Caliper reading, abdominal circumference, and standardized photographs were taken with the Vectra(®) system at all visits. We aim to have the subjects stand and hold the same position and the photograph taken after exhalation. Caliper and circumference measurements carry uncertainty. It is impossible to eliminate all uncertainties but can be improved by having the same trained physician assistant perform the measurement at the same site and taking an average of three readings. Pain score and satisfaction were recorded by means of the visual analogue scale. The efficacy is defined by a statistically significant improvement in circumferential improvement based on intention-to-treat analysis. Seventeen subjects completed the treatment schedule. Abdominal circumference showed statistically significant improvement at 2 weeks post-second treatment (P = 0.023) and almost all subsequent follow-ups. Caliper readings were statistically significant at 2 weeks post-second treatment (P = 0.013) and almost all follow-ups. The mean pain score reported was 2.3 on the visual analog scale and 6% were unsatisfied with the overall treatments. Six incidents of wheal formation appeared immediately after treatment all of which subsided spontaneously within several hours. The combination non-thermal focused ultrasound and radiofrequency device is effective for improving body contour in Asians. © 2015 Wiley Periodicals, Inc.
Ultrasound of the Brachial Plexus.
Griffith, James F
2018-07-01
Examination of the brachial plexus with ultrasound is efficient because it allows many parts of the brachial plexus as well as the surrounding soft tissues to be assessed with high spatial resolution. The key to performing good ultrasound of the brachial plexus is being familiar with the anatomy and the common variants. That makes it possible to concentrate solely on the ultrasound appearances free of simultaneously wondering about the anatomy. Ultrasound of the brachial plexus is particularly good for assessing nerve sheath tumor, perineural fibrosis, metastases, some inflammatory neuropathies, neuralgic amyotrophy, and posttraumatic sequalae. It is limited in the assessment of thoracic outlet syndrome and in the acute/subacute trauma setting. This review addresses the anatomy, ultrasound technique, as well as pathology of the brachial plexus from the cervical foramina to the axilla. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Splenic injury after blunt abdominal trauma during a soccer (football) game.
Padlipsky, Patricia S; Brindis, Seth; Young, Kelly D
2014-10-01
The spleen is the most commonly injured abdominal organ in children who sustain blunt abdominal trauma, and pediatric splenic injury may result from minor mechanisms of injury, including sports participation. We present 2 cases of splenic injury in soccer goalies because of blunt abdominal trauma sustained during game play. Although abdominal organ injuries are uncommon in soccer, emergency medicine and primary care physicians must be aware of the possibility. A high index of suspicion and careful physical examination are key in making the diagnosis.
Code of Federal Regulations, 2010 CFR
2010-10-01
... following risk categories: (i) Has a family history of an abdominal aortic aneurysm. (ii) Is a man age 65 to...: (1) A procedure using soundwaves (or other procedures using alternative technologies of commensurate...
Abdominal epilepsy as an unusual cause of abdominal pain: a case report.
Yunus, Yilmaz; Sefer, Ustebay; Dondu, Ulker Ustebay; Ismail, Ozanli; Yusuf, Ehi
2016-09-01
Abdominal pain, in etiology sometimes difficult to be defined, is a frequent complaint in childhood. Abdominal epilepsy is a rare cause of abdominal pain. In this article, we report on 5 year old girl patient with abdominal epilepsy. Some investigations (stool investigation, routine blood tests, ultrasonography (USG), electrocardiogram (ECHO) and electrocardiograpy (ECG), holter for 24hr.) were done to understand the origin of these complaints; but no abnormalities were found. Finally an EEG was done during an episode of abdominal pain and it was shown that there were generalized spikes especially precipitated by hyperventilation. The patient did well on valproic acid therapy and EEG was normal 1 month after beginning of the treatment. The cause of chronic recurrent paroxymal abdominal pain is difficult for the clinicians to diagnose in childhood. A lot of disease may lead to paroxysmal gastrointestinal symptoms like familial mediterranean fever and porfiria. Abdominal epilepsy is one of the rare but easily treatable cause of abdominal pain. In conclusion, abdominal epilepsy should be suspected in children with recurrent abdominal pain.
Pregnancy sonogram; Obstetric ultrasonography; Obstetric sonogram; Ultrasound - pregnancy; IUGR - ultrasound; Intrauterine growth - ultrasound; Polyhydramnios - ultrasound; Oligohydramnios - ultrasound; Placenta previa - ultrasound; Multiple pregnancy - ultrasound; ...
Ultrasound Imaging of the Musculoskeletal System.
Cook, Cristi R
2016-05-01
Musculoskeletal ultrasound is a rapidly growing field within veterinary medicine. Ultrasound for musculoskeletal disorders has been commonly used in equine and human medicine and is becoming more commonly performed in small animal patients due to the increase in the recognition of soft tissue injuries. Ultrasound is widely available, cost-effective, but technically difficult to learn. Advantages of musculoskeletal ultrasound are the opposite limb is commonly used for comparison to evaluate symmetry of the tendinous structures and the ease of repeat examinations to assess healing. The article discusses the major areas of shoulder, stifle, iliopsoas, gastrocnemius, and musculoskeletal basics. Copyright © 2016 Elsevier Inc. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Snacking is common in adolescents; however, it is unclear if there is an association between snacking and overweight or obesity within the context of the overall diet. This study examined the associations of snacking with weight status and abdominal obesity in adolescents 12–18 y of age (n = 5811). ...
Towards clinical computed ultrasound tomography in echo-mode: Dynamic range artefact reduction.
Jaeger, Michael; Frenz, Martin
2015-09-01
Computed ultrasound tomography in echo-mode (CUTE) allows imaging the speed of sound inside tissue using hand-held pulse-echo ultrasound. This technique is based on measuring the changing local phase of beamformed echoes when changing the transmit beam steering angle. Phantom results have shown a spatial resolution and contrast that could qualify CUTE as a promising novel diagnostic modality in combination with B-mode ultrasound. Unfortunately, the large intensity range of several tens of dB that is encountered in clinical images poses difficulties to echo phase tracking and results in severe artefacts. In this paper we propose a modification to the original technique by which more robust echo tracking can be achieved, and we demonstrate in phantom experiments that dynamic range artefacts are largely eliminated. Dynamic range artefact reduction also allowed for the first time a clinical implementation of CUTE with sufficient contrast to reproducibly distinguish the different speed of sound in different tissue layers of the abdominal wall and the neck. Copyright © 2015. Published by Elsevier B.V.
Ultrasound-guided urinary bladder biopsy through a urinary catheter in a bitch.
Lopez, Julio; Norman, Brian C
2014-01-01
A 34.4 kg 5 yr old spayed female mixed-breed dog was presented for evaluation of a urinary bladder mass. The dog had a recent onset of hematuria and stranguria but otherwise appeared to be healthy. Abdominal ultrasound revealed a mass in the urinary bladder. The dog was sedated and a 10-French rubber catheter that had the blunt end removed was passed from the urethra to the urinary bladder. Using ultrasound guidance, ellipsoid cup biopsy forceps were advanced through the rubber catheter to the urinary bladder mass and biopsies were successfully obtained. The dog was discharged from the hospital a few hours after the procedure. Histopathology of the mass was consistent with polypoid cystitis. Follow-up surgical removal of the polyp was uneventful, and histopathology confirmed the presurgical biopsy diagnosis. Procurement of urinary bladder biopsies through a urinary catheter with ultrasound guidance was used as a minimally invasive alternative to either cystoscopy or surgery in a bitch. Use of this technique achieved a diagnosis without the need for specialized endoscopic equipment, anesthesia, or surgery.
Does abdominal obesity accelerate the effect of hypertriglyceridemia on impaired fasting glucose?
Lee, Soojin; Chun, Kihong; Lee, Soonyoung; Kim, Daejung
2010-05-01
This study sought to determine whether abdominal obesity is a risk factor for impaired fasting glucose (IFG) and hypertriglyceridemia and to verify whether moderate effect of abdominal obesity on the relationship between IFG and hypertriglyceridemia in Korea. Data from the Korean National Health and Nutrition Examination Survey was used for the analysis. The study population included 5,938 subjects aged 20 year old drawn from non-diabetic participants in a health examination survey. The subjects were classified according to the presence of abdominal obesity based on waist circumference, IFG based on their fasting blood glucose level, and hypertriglyceridemia on their fasting triglyceride. The multivariate-adjusted odds ratios for the occurrence of hypertriglyceridemia were 2.91 in the abdominal obesity group as compared with the nonobesity group and 1.31 in subjects with IFG compared with the normoglycemia controls. Abdominal obesity was found to be positively moderated in the interaction between waist circumference and fasting blood sugar. The moderate effect between abdominal obesity and IFG contributes to the development of hypertriglyceridemia in Korea.
Hung, Joseph C; Azam, Nyla; Puttanniah, Vinay; Malhotra, Vivek; Gulati, Amitabh
2014-01-01
There have been several case reports in the literature of neurolytic transversus abdominis plane (TAP) blocks being used for malignant abdominal wall pain. However, most used phenol as a neurolytic agent. We found only a single case report by Sakamoto using alcohol for TAP neurolysis. Unfortunately this patient passed away only 5 days after performance of the block. We attempt to extend upon the existing literature by describing neurolytic TAP blockade outcomes using alcohol on 3 cancer patients with metastatic disease to the abdominal wall. Two of our 3 patients had colorectal cancer invading the abdominal musculature. The third patient had a metastatic neuroendocrine nodule in the left rectus muscle. In our case series, all 3 patients had sustained and significant (greater than 50%) relief of abdominal wall pain after performing TAP neurolysis using alcohol. Ultrasound guidance was used for all blocks. The concentration of alcohol used varied from 33% to 77% between patients. Duration of relief lasted between 17 days and 6 months. Opioid use either decreased or remained relatively stable for prolonged periods of time after neurolysis. Other than one patient with transient post-procedure pain related to alcohol injection, there were no significant complications. Addition of a depo steroid for diagnostic TAP blockade prior to neurolysis did not appear to extend or provide additional analgesia. Based on our observations, TAP neurolysis using alcohol also offers a feasible option for long-term control of malignant abdominal wall pain. Further investigation is needed to determine if alcohol offers any significant advantage compared with phenol.
Sainani, Nisha I; Arellano, Ronald S; Shyn, Paul B; Gervais, Debra A; Mueller, Peter R; Silverman, Stuart G
2013-08-01
Image-guided percutaneous biopsy of abdominal masses is among the most commonly performed procedures in interventional radiology. While most abdominal masses are readily amenable to percutaneous biopsy, some may be technically challenging for a number of reasons. Low lesion conspicuity, small size, overlying or intervening structures, motion, such as that due to respiration, are some of the factors that can influence the ability and ultimately the success of an abdominal biopsy. Various techniques or technologies, such as choice of imaging modality, use of intravenous contrast and anatomic landmarks, patient positioning, organ displacement or trans-organ approach, angling CT gantry, triangulation method, real-time guidance with CT fluoroscopy or ultrasound, sedation or breath-hold, pre-procedural image fusion, electromagnetic tracking, and others, when used singularly or in combination, can overcome these challenges to facilitate needle placement in abdominal masses that otherwise would be considered not amenable to percutaneous biopsy. Familiarity and awareness of these techniques allows the interventional radiologist to expand the use of percutaneous biopsy in clinical practice, and help choose the most appropriate technique for a particular patient.
Endovaginal ultrasound; Ultrasound - transvaginal; Fibroids - transvaginal ultrasound; Vaginal bleeding - transvaginal ultrasound; Uterine bleeding - transvaginal ultrasound; Menstrual bleeding - transvaginal ultrasound; ...
Bozeman, Matthew C.; Ross, Charles B.
2012-01-01
Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) are common complications of ruptured abdominal aortoiliac aneurysms (rAAAs) and other abdominal vascular catastrophes even in the age of endovascular therapy. Morbidity and mortality due to systemic inflammatory response syndrome (SIRS) and multiple organ failure (MOF) are significant. Recognition and management of IAH are key critical care measures which may decrease morbidity and improve survival in these vascular patients. Two strategies have been utilized: expectant management with prompt decompressive laparotomy upon diagnosis of threshold levels of IAH versus prophylactic, delayed abdominal closure based upon clinical parameters at the time of initial repair. Competent management of the abdominal wound with preservation of abdominal domain is also an important component of the care of these patients. In this review, we describe published experience with IAH and ACS complicating abdominal vascular catastrophes, experience with ACS complicating endovascular repair of rAAAs, and techniques for management of the abdominal wound. Vigilance and appropriate management of IAH and ACS remains critically important in decreasing morbidity and optimizing survival following catastrophic intra-abdominal vascular events. PMID:22454763
Bozeman, Matthew C; Ross, Charles B
2012-01-01
Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) are common complications of ruptured abdominal aortoiliac aneurysms (rAAAs) and other abdominal vascular catastrophes even in the age of endovascular therapy. Morbidity and mortality due to systemic inflammatory response syndrome (SIRS) and multiple organ failure (MOF) are significant. Recognition and management of IAH are key critical care measures which may decrease morbidity and improve survival in these vascular patients. Two strategies have been utilized: expectant management with prompt decompressive laparotomy upon diagnosis of threshold levels of IAH versus prophylactic, delayed abdominal closure based upon clinical parameters at the time of initial repair. Competent management of the abdominal wound with preservation of abdominal domain is also an important component of the care of these patients. In this review, we describe published experience with IAH and ACS complicating abdominal vascular catastrophes, experience with ACS complicating endovascular repair of rAAAs, and techniques for management of the abdominal wound. Vigilance and appropriate management of IAH and ACS remains critically important in decreasing morbidity and optimizing survival following catastrophic intra-abdominal vascular events.
Performance of chest ultrasound in pediatric pneumonia.
Claes, Anne-Sophie; Clapuyt, Philippe; Menten, Renaud; Michoux, Nicolas; Dumitriu, Dana
2017-03-01
The objective of this study was to evaluate the performance of ultrasound in detecting lung consolidation in children suspected of pneumonia, in comparison to the current gold standard, chest X-rays. From September 2013 to June 2014, a monocentric prospective study was performed on all children between 0 and 16 years-old, referred for chest X-ray for suspected pneumonia. Each child was examined by chest ultrasound by an examiner blinded to the chest X-ray. The presence or absence of areas of consolidation, their number and location were noted for each technique. The size of the consolidations identified only on ultrasound was compared with that of consolidations visible on both techniques. 143 children (mean age 3 years; limits between 8days and 14 years) were included. Ultrasound detected at least one area of consolidation in 44 out of 45 patients with positive X-rays. Of the 59 areas of consolidation on X-ray, ultrasound identified 54. In the 8 patients with negative X-ray, ultrasound revealed 17 areas of consolidation. The mean size of consolidations visible only on ultrasound was 9.4mm; for consolidations visible on both techniques the mean size was 26mm (p<0.0001). The sensitivity and specificity of ultrasound were calculated at 98% and 92%. PPV and NPV were 85% and 99%, respectively. Chest ultrasound is a fast, non-ionizing and feasible technique. With its high negative predictive value, it can replace X-rays in order to exclude lung consolidation in children, thus reducing radiation exposure in this population. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
The role for peer-assisted ultrasound teaching in medical school.
Dickerson, Jonathan; Paul, Katie; Vila, Pierre; Whiticar, Rebecca
2017-06-01
Bedside ultrasonography has an increasing role in medicine yet medical students have limited exposure. Although countless hours are devoted to plain radiograph and electrocardiogram (ECG) interpretation, ultrasound is frequently glossed over. Yet this imaging modality could enhance students' understanding of anatomy, physiology and pathology, and may increase their integration into hospital teams. We aimed to investigate whether a peer-assisted ultrasound course has a place within the undergraduate medical curriculum. We describe the implementation of a course and discuss its acceptability and utility in student education. Bedside ultrasonography has an increasing role in medicine yet medical students have limited exposure METHODS: Following consultation with the medical school, an improved ultrasonography course was developed with expert guidance from an ultrasonographer and with new equipment. Sessions involved peer-tutors teaching ultrasonography techniques to medical students during emergency medicine placements. Tutees completed questionnaires to assess the quality and perceived benefits of the course and of learning ultrasonography. Both quantitative and thematic analyses of the responses were conducted by the authors. Over a period of 8 months, 105 medical students received teaching across four sessions. A total of 103 students (98%) returned questionnaires on their evaluation of the course and tutors, and on their confidence in using ultrasound. Ninety-eight per cent felt that the teaching was well delivered, 100 per cent felt that their knowledge of ultrasound had improved and 100 per cent would recommend the course. The peer-assisted ultrasound course described here enabled the majority of students to feel confident gaining elementary ultrasound views, and performing abdominal aneurysm screening and trauma assessments: techniques that they could hopefully put to use during their placements. The peer-assisted model has an acceptable role in teaching
Computed tomography use among children presenting to emergency departments with abdominal pain.
Fahimi, Jahan; Herring, Andrew; Harries, Aaron; Gonzales, Ralph; Alter, Harrison
2012-11-01
To evaluate trends in and factors associated with computed tomography (CT) use among children presenting to the emergency department (ED) with abdominal pain. This study was a cross-sectional, secondary analysis of the National Hospital Ambulatory Medical Care Survey data from 1998 to 2008. We identified ED patients aged <19 years with abdominal pain and collected patient demographic and hospital characteristics, and outcomes related to imaging, hospital admission, and diagnosis of appendicitis. Trend analysis was performed over the study period for the outcomes of interest, and a multivariate regression model was used to identify factors associated with CT use. Of all pediatric ED visits, 6.0% were for abdominal pain. We noted a rise in the proportion of these patients with CT use, from 0.9% in 1998 to 15.4% in 2008 (P < .001), with no change in ultrasound/radiograph use, diagnosis of appendicitis, or hospital admission. Older and male patients were more likely to have a CT scan, whereas black children were one-half as likely to undergo a CT scan compared with white children (odds ratio: 0.50 [95% confidence interval: 0.31-0.81]). Admitted children had much higher odds of undergoing a CT scan (odds ratio: 4.11 [95% confidence interval: 2.66-6.35]). There was a plateau in CT use in 2006 to 2008. There was a dramatic increase in the utilization of CT imaging in the ED evaluation of pediatric patients with abdominal pain. Some groups of children may have a differential likelihood of receiving CT scans.
Peyronnet, V; Kayem, G; Mandelbrot, L; Sibiude, J
2016-09-01
Fetus small for gestational age (SGA) screening rate is evaluated around 21,7 % in France. Recommendations were developed to improve the efficiency of ultrasound conducted in the third trimester (T3), because neonatal consequences can be significant. This study aims to evaluate screening of SGA during T3 ultrasound and to describe causes for failure and differences with the recommendations of CNGOF. All children born between 2011 and 2012 with a birth weight below the 3rd percentile were included in this observational, retrospective, monocentric study. We noted that the diagnosis of SGA was placed on file. Then, as recommended by the CNGOF, we calculated estimated fetal weight (EFW) with Hadlock 3 and Hadlock 4, and the corresponding percentiles, using the biometrics from the ultrasound report. We thus could evaluate a new screening rate with SGA fetus identified through this technique. A total of 142 patients were included. By calculating correctly all EFW and checking abdominal circumference percentiles, the screening rate of SGA fetuses with T3 ultrasound increased from 40 % to 50 % and the overall screening rate (clinical and ultrasound) from 54 % to 66 %. By following the recommendations we found a real improvement in fetal SGA screening rates to T3 ultrasound with a potential benefit for their care. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Ahn, Jae Hoon; Lee, Choong Woo; Park, ChanJoo; Kim, Yoon-Chung
2016-01-01
Musculoskeletal ultrasound is a non-invasive and low-cost modality for real-time visualisation of the plantar fascia. Ultrasound examination for plantar fasciitis is generally performed with the patient in a prone position, although the rational for using a prone position has not been validated. The aim of the study was to investigate if ultrasound examination in a supine position, which is more comfortable than the prone position, is valid. We conducted a prospective study of 30 participants with plantar fasciitis, 8 men (27 %) and 22 women (73 %), with a mean age of 53.9 ± 12.6 (range, 32 to 77) years, and an equal distribution of left and right feet. The plantar heel was divided into three portions for ultrasound examination: medial, central and lateral. Two measurements of plantar fascia thickness were obtained for each portion, with participants in 2 positions (supine and prone) and for 2 ankle postures (neutral and 15° of plantarflexion). Mean measurements of plantar fascia thickness were compared between the two positions (Wilcoxon signed rank tests for non-normally distributed data and paired t-tests for normally distributed data). Participants were asked to report their preferred position for examination, supine or prone. The measured thickness was comparable for both supine and prone positions, for both ankle postures, neutral and 15° of plantarflexion (p > 0.05). A specific self-reported preferred position was not identified. Ultrasound examination of plantar fasciitis can be performed in the supine position without any significant difference in measurement compared to examination in the conventional prone position. The Catholic Medical Center Office of Human Research Protection Program (CMC-OHRP)/Institutional Review Board approved the current study (Approval No. KC12DISI0338), and all participants provided their written informed consent for participation and publication.
An investigation of abdominal muscle recruitment for sustained phonation in 25 healthy singers.
Macdonald, Ian; Rubin, John S; Blake, Ed; Hirani, Shashi; Epstein, Ruth
2012-11-01
The purpose of this study was to investigate the baseline muscle thickness and recruitment patterns of the transversus abdominis muscle (TAM) and the internal oblique muscle (IOM) during semisupine phonation in a group of healthy performers. This was a 2 × 3×2 within-group, repeated-measure study in which 25 professional vocalists--12 male and 13 female performed a series of sustained pitches in differing vocal qualities. Measurements were taken with ultrasound (Sonosite Micromaxx Ultrasound System) of the baseline thickness and % recruitment during voicing, of two deep abdominal muscles--TAM and the IOM. Correlations between TAM and IOM absolute change scores, TAM and IOM percentage change scores, and changes in muscle thickness (absolute and percentage) and age were examined using Spearman's correlations. Gender differences in the four types of change scores within each combination of pitch and quality were conducted with one-way analysis of variances. Differences in muscle thickness change 1) absolute scores and 2) percentage change in TAM and IOM, by pitch and quality (and their interactions) were analyzed using linear mixed models, using restricted maximum likelihood estimations, employing a Toeplitz variance-covariance matrix structure in SPSS (IBM, 2011). Post hoc analyses for independent variable group differences used Sidak's correction for multiple comparisons. Alpha level was set to 0.05. In terms of absolute contractions (changes in the actual millimeter thickness of the muscle), the IOM was greater than the TAM. However in terms of percentage changes in muscles during phonation, the TAM was always greater than the IOM. The TAM as a percentage change was recruited preferentially and significantly in most vocal qualities tested. Although there were differences in muscle mass and recruitment patterns between genders, and males had thicker muscle mass at rest, differences due to muscle mass were not conclusive. Overall this study supports the argument
... community Home > Pregnancy > Prenatal care > Ultrasound during pregnancy Ultrasound during pregnancy E-mail to a friend Please ... you. What are some reasons for having an ultrasound? Your provider uses ultrasound to do several things, ...
... Kids and Teens Pregnancy and Childbirth Women Men Seniors Your Health Resources Healthcare Management End-of-Life ... familydoctor.org editorial staff Categories: Family Health, Men, Seniors, WomenTags: abdominal aorta, abdominal aortic aneurysm, abdominal pain, ...
Medellin-Kowalewski, Alexandra; Wilkens, Rune; Wilson, Alexandra; Ruan, Ji; Wilson, Stephanie R
2016-01-01
The primary objective of our study was to examine the association between contrast-enhanced ultrasound (CEUS) parameters and established gray-scale ultrasound with color Doppler imaging (CDI) for the determination of disease activity in patients with Crohn disease. Our secondary objective was to develop quantitative time-signal intensity curve thresholds for disease activity. One hundred twenty-seven patients with Crohn disease underwent ultrasound with CDI and CEUS. Reviewers graded wall thickness, inflammatory fat, and mural blood flow as showing remission or inflammation (mild, moderate, or severe). If both gray-scale ultrasound and CDI predicted equal levels of disease activity, the studies were considered concordant. If ultrasound images suggested active disease not supported by CDI findings, the ultrasound results for disease activity were indeterminate. Time-signal intensity curves from CEUS were acquired with calculation of peak enhancement (PE), and AUCs. Interobserver variation and associations between PE and ultrasound parameters were examined. Multiclass ROC analysis was used to develop CEUS thresholds for activity. Ninety-six (76%) studies were concordant, 19 of which showed severe disease, and 31 (24%) studies were indeterminate. Kappa analyses revealed good interobserver agreement on grades for CDI (κ = 0.76) and ultrasound (κ = 0.80) assessments. PE values on CEUS and wall thickness showed good association with the Spearman rank correlation coefficient for the entire population (ρ = 0.62, p < 0.01) and for the concordant group (ρ = 0.70, p < 0.01). Multiclass ROC analyses of the concordant group using wall thickness alone as the reference standard showed cutoff points of 18.2 dB for differentiating mild versus moderate activity (sensitivity, 89.0% and specificity, 87.0%) and 23.0 dB for differentiating moderate versus severe (sensitivity, 90% and specificity, 86.8%). Almost identical cutoff points were observed when using ultrasound global
Jewell, Mark L; Baxter, Richard A; Cox, Sue Ellen; Donofrio, Lisa M; Dover, Jeffrey S; Glogau, Richard G; Kane, Michael A; Weiss, Robert A; Martin, Patrick; Schlessinger, Joel
2011-07-01
High-intensity focused ultrasound presents a noninvasive approach to body sculpting for nonobese patients. The purpose of this study was to evaluate the safety and effectiveness of a high-intensity focused ultrasound device for sculpting of the abdomen and flanks. Adults (aged 18 to 65 years) with subcutaneous abdominal fat greater than or equal to 2.5 cm thick who met screening criteria were randomized to receive high-intensity focused ultrasound treatment of the anterior abdomen and flanks at energy levels (a total of three passes each) of 47 J/cm (141 J/cm total), 59 J/cm (177 J/cm), or 0 J/cm (no energy applied, sham control). The primary endpoint was change from baseline waist circumference at the iliac crest level at posttreatment week 12. Subjective aesthetic assessments included the Global Aesthetic Improvement Scale and a patient satisfaction questionnaire. Safety assessments included adverse events, laboratory values, and physical examinations. For the primary endpoint, in the intent-to-treat population, statistical significance versus sham was achieved for the 59-J/cm (-2.44; p = 0.01) but not the 47-J/cm treatment group (-2.06 cm; p = 0.13). In a per-protocol population, statistical significance versus sham was achieved for both the 59-J/cm (-2.52 cm; p = 0.002) and the 47-J/cm treatment groups (-2.10 cm; p = 0.04). Investigator subjective measures of global aesthetic improvement and patient satisfaction also favored each active treatment versus sham. Adverse events included mild to moderate discomfort, bruising, and edema. Laboratory values and physical examinations were unremarkable. Treatment with this high-intensity focused ultrasound device reduced waist circumference and was generally well tolerated for noninvasive body sculpting. Reduction in waist circumference was statistically significant with both active treatments (per protocol). Therapeutic, II.(Figure is included in full-text article.).
Does endoscopic ultrasound improve detection of locally recurrent anal squamous-cell cancer?
Peterson, Carrie Y; Weiser, Martin R; Paty, Philip B; Guillem, Jose G; Nash, Garrett M; Garcia-Aguilar, Julio; Patil, Sujata; Temple, Larissa K
2015-02-01
Evaluating patients for recurrent anal cancer after primary treatment can be difficult owing to distorted anatomy and scarring. Many institutions incorporate endoscopic ultrasound to improve detection, but the effectiveness is unknown. The aim of this study is to compare the effectiveness of digital rectal examination and endoscopic ultrasound in detecting locally recurrent disease during routine follow-up of patients with anal cancer. This study is a retrospective, single-institution review. This study was conducted at an oncologic tertiary referral center. Included were 175 patients with nonmetastatic anal squamous-cell cancer, without persistent disease after primary chemoradiotherapy, who had at least 1 posttreatment ultrasound and examination by a colorectal surgeon. The primary outcomes measured were the first modality to detect local recurrence, concordance, crude cancer detection rate, sensitivity, specificity, and predictive value. Eight hundred fifty-five endoscopic ultrasounds and 873 digital rectal examinations were performed during 35 months median follow-up. Overall, ultrasound detected 7 (0.8%) mesorectal and 32 (3.7%) anal canal abnormalities; digital examination detected 69 (7.9%) anal canal abnormalities. Locally recurrent disease was found on biopsy in 8 patients, all detected first or only with digital examination. Four patients did not have an ultrasound at the time of diagnosis of recurrence. The concordance of ultrasound and digital examination in detecting recurrent disease was fair at 0.37 (SE, 0.08; 95% CI, 0.21-0.54), and there was no difference in crude cancer detection rate, sensitivity, specificity, and negative or positive predictive values. The heterogeneity of follow-up timing and examinations is not standardized in this study but is reflective of general practice. Endoscopic ultrasound did not provide any advantage over digital rectal examination in identifying locally recurrent anal cancer, and should not be recommended for
Whittaker, Jackie L; Warner, Martin B; Stokes, Maria
2013-01-01
Cross-sectional, case-control study. To measure and compare the resting thickness of the 4 abdominal wall muscles, their associated perimuscular connective tissue (PMCT), and interrecti distance (IRD) in persons with and without lumbopelvic pain (LPP), using ultrasound imaging. The muscles and PMCT of the abdominal wall assist in controlling the spine. Functional deficits of the abdominal wall muscles have been detected in populations with LPP. Investigations of the abdominal wall in those with LPP are primarily concerned with muscle, most commonly the transversus abdominis (TrA) and internal oblique (IO). Because the abdominal wall functions as a unit, all 4 abdominal muscles and their associated connective tissues should be considered concurrently. B-mode ultrasound imaging was used to measure the resting thickness of the rectus abdominis (RA), external oblique, IO, and TrA muscles; the PMCT planes; and IRD in 50 male and female subjects, 25 with and 25 without LPP (mean ± SD age, 36.3 ± 9.4 and 46.6 ± 8.0 years, respectively). Univariate correlation analysis was used to identify covariates. Analyses of covariance (ANCOVAs) and the Kruskal-Wallis test (IRD) were used to compare cohorts (α = .05). The LPP cohort had less total abdominal muscle thickness (LPP mean ± SD, 18.9 ± 3.0 mm; control, 20.3 ± 3.0 mm; ANCOVA adjusted for body mass index, P = .03), thicker PMCT (LPP, 5.5 ± 0.2 mm; control, 4.3 ± 0.2 mm; ANCOVA adjusted for body mass index, P = .007), and wider IRD (LPP, 11.5 ± 2.0 mm; control, 8.4 ± 1.8 mm; Kruskal-Wallis, P = .005). Analysis of individual muscle thickness revealed no difference in the external oblique, IO, and TrA, but a thinner RA in the LPP cohort (LPP mean ± SD, 7.8 ± 1.5 mm; control, 9.1 ± 1.2 mm; ANCOVA adjusted for body mass index, P<.001). To our knowledge, this is the first study to investigate the morphological characteristics of all 4 abdominal muscles and PMCT in individuals with LPP. The results suggest that there
Ultrasound biomicroscopic findings in hallerman-streiff syndrome.
Sato, Miho; Terasaki, Hiroko; Amano, Emil; Okamoto, Yoko; Miyake, Yozo
2002-01-01
To demonstrate the usefulness of ultrasound biomicroscopy in detecting the morphological changes in the lens caused by the spontaneous absorption of lens material and to detect fundus abnormalities in a patient with Hallermann-Streiff syndrome. Case report of an infant diagnosed at the age of 2 months as having Hallermann-Streiff syndrome. Spontaneous lens absorption occurred during the course of follow-up and was detected only by ultrasound biomicroscopy after the patient was prepared for cataract surgery. The changes in the anterior chamber depth and lens shapes were documented by ultrasound biomicroscopy. Retinal folds that were barely observable by conventional ophthalmoscopy because of a dense cataract were clearly shown by ultrasound biomicroscopy. Ultrasound biomicroscopy can be used to examine the lenses of eyes that are not observable with conventional optical instruments. Ultrasound biomicroscopy can also be used to study the posterior segment of microphthalmic eyes. We recommend preoperative ultrasound biomicroscopy to prevent unnecessary anesthesia and surgical preparation.
Geerts, L T; Brand, E J; Theron, G B
1996-06-01
To compare routine midtrimester with selective obstetric ultrasonography concerning the Health Service cost and the effect on perinatal outcome. A randomised controlled trial. Urban area served by Tygerberg Hospital, a tertiary referral centre in South Africa. Pregnant patients without risk factors for congenital anomalies referred for ultrasonography between 18 and 24 weeks of gestation. Between 18 and 24 weeks, a level one ultrasound examination was performed on study patients only. Except for the routine scan, both groups received the same antenatal care and could be referred later for additional scans as judged by their clinicians. Overall adverse perinatal outcome and use of antenatal and neonatal services. The groups did not differ significantly in their use of antenatal and neonatal services except for a greater number of ultrasound scans in the study group. More suspected postdate pregnancies occurred in control patients, as well as more amniocenteses for confirmation of lung maturity. More babies of low birthweight were born in the study group. The incidence of overall or major adverse perinatal outcome was comparable. Routine ultrasonography was accompanied by a considerable increase in costs. Selective use of obstetric ultrasonography did not increase the use of antenatal and neonatal services. Not routinely performing ultrasonography has led to considerable Health Service savings without increasing the risk for adverse perinatal outcome. It saved 75% of selected patients a referral to an ultrasound unit. Specific problems related to inaccurate gestational age determination need to be addressed.
Spinal curvature measurement by tracked ultrasound snapshots.
Ungi, Tamas; King, Franklin; Kempston, Michael; Keri, Zsuzsanna; Lasso, Andras; Mousavi, Parvin; Rudan, John; Borschneck, Daniel P; Fichtinger, Gabor
2014-02-01
Monitoring spinal curvature in adolescent kyphoscoliosis requires regular radiographic examinations; however, the applied ionizing radiation increases the risk of cancer. Ultrasound imaging is favored over radiography because it does not emit ionizing radiation. Therefore, we tested an ultrasound system for spinal curvature measurement, with the help of spatial tracking of the ultrasound transducer. Tracked ultrasound was used to localize vertebral transverse processes as landmarks along the spine to measure curvature angles. The method was tested in two scoliotic spine models by localizing the same landmarks using both ultrasound and radiographic imaging and comparing the angles obtained. A close correlation was found between tracked ultrasound and radiographic curvature measurements. Differences between results of the two methods were 1.27 ± 0.84° (average ± SD) in an adult model and 0.96 ± 0.87° in a pediatric model. Our results suggest that tracked ultrasound may become a more tolerable and more accessible alternative to radiographic spine monitoring in adolescent kyphoscoliosis. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Ramsingh, Davinder; Alexander, Brenton; Le, Khanhvan; Williams, Wendell; Canales, Cecilia; Cannesson, Maxime
2014-09-01
To expose residents to two methods of education for point-of-care ultrasound, a traditional didactic lecture and a model/simulation-based lecture, which focus on concepts of cardiopulmonary function, volume status, and evaluation of severe thoracic/abdominal injuries; and to assess which method is more effective. Single-center, prospective, blinded trial. University hospital. Anesthesiology residents who were assigned to an educational day during the two-month research study period. Residents were allocated to two groups to receive either a 90-minute, one-on-one didactic lecture or a 90-minute lecture in a simulation center, during which they practiced on a human model and simulation mannequin (normal pathology). Data points included a pre-lecture multiple-choice test, post-lecture multiple-choice test, and post-lecture, human model-based examination. Post-lecture tests were performed within three weeks of the lecture. An experienced sonographer who was blinded to the education modality graded the model-based skill assessment examinations. Participants completed a follow-up survey to assess the perceptions of the quality of their instruction between the two groups. 20 residents completed the study. No differences were noted between the two groups in pre-lecture test scores (P = 0.97), but significantly higher scores for the model/simulation group occurred on both the post-lecture multiple choice (P = 0.038) and post-lecture model (P = 0.041) examinations. Follow-up resident surveys showed significantly higher scores in the model/simulation group regarding overall interest in perioperative ultrasound (P = 0.047) as well understanding of the physiologic concepts (P = 0.021). A model/simulation-based based lecture series may be more effective in teaching the skills needed to perform a point-of-care ultrasound examination to anesthesiology residents. Copyright © 2014 Elsevier Inc. All rights reserved.
[Ultrasound biomicroscopy of conjunctival lesions].
Buchwald, Hans-Jürgen; Müller, Andreas; Spraul, Christoph W; Lang, Gerhard K
2003-01-01
The value of ultrasound biomicroscopy in the diagnosis of conjunctival lesions is not well established. For the examination of conjunctival lesions, we used an ultrasound biomicroscope (Humphrey, Zeiss, Oberkochen) with a high frequency transducer (30 MHz). Between January 2000 and August 2001, 28 patients (16 female, 12-male) with conjunctival lesions, aged 9 to 81 years, were available for this study. Histological examination of the excised tissue displayed the presence of a compound naevus (8/28), cysts (6/28), inflammatory processes (3/28), granulomatous processes (2/28), lymphomas (2/28), foreign bodies (2/28), a pterygium (2/28), a malignant melanoma (1/28), a primary acquired melanosis (1/28), and a conjunctival amyloidosis (1/28). Using ultrasound biomicroscopy we were able to demonstrate a cystic tumour in the six patients (21 %) with a cyst of the conjunctiva. In patients suffering from solid tumours of the conjunctiva the definite diagnosis could not be made with ultrasound biomicroscopy alone. The eight patients with compound naevus displayed a somewhat heterogeneous sonographic structure within the tumour. In the patient with a foreign body we were able to demonstrate posterior shadowing of the underlying tissue. For evaluation of conjunctival lesions caused by a cyst or a solid tumour, ultrasound biomicroscopy may be an additional diagnostic tool, e. g. for assessing the margins of the tumour. However, up to now it is not possible to differentiate between different lesions solely by means of ultrasonography.
Gastrointestinal injuries from blunt abdominal trauma in children.
Ameh, E A; Nmadu, P T
2004-04-01
To determine the pattern, presentation and outcome of gastrointestinal injuries from blunt abdominal trauma in children. A retrospective study. Ahmadu Bello University Teaching Hospital, Zaria, Nigeria. Twenty one children managed for gastrointestinal injuries from blunt trauma from 1984-2002. The pattern, presentation, management and outcome of gastrointestinal injuries from blunt trauma. In the 19 year period, 1984-2002, 92 children were treated for blunt abdominal trauma, 21(23%) of who had injuries to the gastrointestinal tract. Three presenting after 24 hours had evidence of peritonitis. In six children with isolated gastrointestinal tract (GIT) injury who presented within two hours, abdominal signs were vague at initial evaluation but became marked over a few hours at repeated examination. In eight with associated intraabdominal injuries, abdominal signs were marked at initial examination and five presented with shock. Free peritoneal air was present on plain abdominal and chest radiograph in three of ten patients, dilated bowel loops in six and fluid levels in one. Diagnostic peritoneal lavage or paracentesis was positive in four patients with isolated GIT injuries and eight with associated intraabdominal injuries. There were 24 injuries in the 21 patients consisting of 15 perforations, five contusions, two seromuscular tears, and two gangrene from mesenteric injury. The small intestine was involved in 11 patients, colon six, stomach five, duodenum one and rectum one. Seven (35%) patients had associated extraabdominal injuries. Treatment consisted of simple closure of perforations, over sewing of contusions, resection and anastomosis for gangrene and repair with protective stoma for the rectal injury. One patient each developed prolonged ileus, urinary tract infection and chest infection, respectively postoperatively. Mortality was 28%, all of who had associated intraabdominal or extraabdominal injuries. Gastrointestinal injury from blunt abdominal trauma in
Delayed rupture of gallbladder following blunt abdominal trauma.
Mohanty, Debajyoti; Agarwal, Himanshu; Aggarwal, Krittika; Garg, Pankaj Kumar
2014-09-01
A 29-year-old gentleman presented to surgery emergency with severe upper abdominal pain and vomiting. He reported to had been hit in his abdomen by a ball during a cricket match. Computerized tomogram of the abdomen revealed hematoma within the gallbladder lumen, laceration of segment six of liver, and hemoperitoneum. The patient did not agree for laparotomy advised to him, and so, managed conservatively. The patient reported back to us with high grade fever, jaundice, and painful abdominal distension after seven days of discharge from the hospital. His abdominal examination showed features of generalized peritonitis. Surgical abdominal exploration revealed a single perforation in the fundus of gallbladder with frozen calot'striangle. Subtotal cholecystectomy was done. Histopathology of excised gallbladder revealed xanthogranulomatous inflammation. The present case report highlights that early exploration and cholecystectomy should be considered in patients with gallbladder injury to obviate the risk of delayed perforation.
Hides, Julie A; Endicott, Timothy; Mendis, M Dilani; Stanton, Warren R
2016-07-01
To investigate whether motor control training alters automatic contraction of abdominal muscles in elite cricketers with low back pain (LBP) during performance of a simulated unilateral weight-bearing task. Clinical trial. 26 male elite-cricketers attended a 13-week cricket training camp. Prior to the camp, participants were allocated to a LBP or asymptomatic group. Real-time ultrasound imaging was used to assess automatic abdominal muscle response to axial loading. During the camp, the LBP group performed a staged motor control training program. Following the camp, the automatic response of the abdominal muscles was re-assessed. At pre-camp assessment, when participants were axially loaded with 25% of their own bodyweight, the LBP group showed a 15.5% thicker internal oblique (IO) muscle compared to the asymptomatic group (p = 0.009). The post-camp assessment showed that participants in the LBP group demonstrated less contraction of the IO muscle in response to axial loading compared with the asymptomatic group. A trend was found in the automatic recruitment pattern of the transversus abdominis (p = 0.08). Motor control training normalized excessive contraction of abdominal muscles in response to a low load task. This may be a useful strategy for rehabilitation of cricketers with LBP. Copyright © 2016 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Omari, E; Noid, G; Ehlers, C
Purpose: Substantial target motion during the delivery of radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor on RT effectiveness. The aim of this work is to monitor intra-fractional motion of the pancreas using ultrasound during RT delivery. Methods: Transabdominal Ultrasound B-mode images were collected from 5 volunteers using a research version of the Clarity Autoscan System (Elekta). The autoscan transducer with center frequency of 5 MHz was utilized for the scans. Imaging parameters were adjusted to acquire images at the desired depth with good contrast and a wide sweep angle. Since well-defined boundaries ofmore » the pancreas can be difficult to find on ultrasound B-mode images, the portal vein was selected as a surrogate for motion estimation of the head of the pancreas. The selection was due to its anatomical location posterior to the neck of the pancreas and close proximity to the pancreas head. The portal vein was contoured on the ultrasound images acquired during simulation using the Clarity Research AFC Workstation software. Volunteers were set up in a similar manner to the simulation for their monitoring session and the ultrasound transducer was mounted on an arm fixed to the couch. A video segment of the portal vein motion was captured. Results: The portal vein was visualized and segmented. Successful monitoring sessions of the portal vein were observed. In addition, our results showed that the ultrasound transducer itself reduces breathing related motion. This is analogous to the use of a compression plate to suppress respiration motion during thorax or abdominal irradiation. Conclusion: We demonstrate the feasibility of tracking the pancreas through the localization of the portal vein using abdominal ultrasound. This will allow for real-time tracking of the intra-fractional motion to justify PTV-margin and to account for unusual motions, thus, improving normal tissue sparing. This research was funding in
Intra-abdominal hypertension and abdominal compartment syndrome in pediatrics. A review.
Thabet, Farah Chedly; Ejike, Janeth Chiaka
2017-10-01
To consolidate pediatric intensivists' understanding of the pathophysiology, definition, incidence, monitoring, and management of intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS); and to highlight the characteristics related to the pediatric population. This is a narrative review article that utilized a systematic search of the medical literature published in the English language between January 1990 and august 2016. Studies were identified by conducting a comprehensive search of Pub Med databases. Search terms included "intra-abdominal hypertension and child", "intra-abdominal hypertension and pediatrics", "abdominal compartment syndrome and child", and "abdominal compartment syndrome and pediatrics". Intra-abdominal hypertension and ACS are associated with a number of pathophysiological disturbances and increased morbidity and mortality. These conditions have been well described in critically ill adults. In children, the IAH and the ACS have a reported incidence of 13% and 0.6 to 10% respectively; they carry similar prognostic impact but are still under-diagnosed and under-recognized by pediatric health care providers. Intra-abdominal hypertension and ACS are conditions that are regularly encountered in critically ill children. They are associated with an increased morbidity and mortality. Early recognition, prevention and timely management of this critical condition are necessary to improve its outcome. Copyright © 2017 Elsevier Inc. All rights reserved.
Measurement the thickness of the transverse abdominal muscle in different tasks.
Pang, Ling; Yin, Liquan; Tajiri, Kimiko; Huo, Ming; Maruyama, Hitoshi
2017-02-01
[Purpose] This study examined the measurement of the thickness of the transverse abdominal muscle in different tasks. [Subjects and Methods] The subjects were eleven healthy adult females. Thicknesses of transverse abdominal muscle were measured in seven tasks in the supine position. The tasks were: 1) Resting state, 2) Maximal contraction of transverse abdominal muscle, 3) Maximal contraction of levator ani muscle, 4) Maximal simultaneous contraction of both transverse abdominal muscle and levator ani muscle, 5) Maximal simultaneous contraction of both transverse abdominal muscle and levator ani muscle with front side resistance added to both knee, 6) Maximal simultaneous contraction of both transverse abdominal muscle and levator ani muscle with diagonal resistance added to both knees, and 7) Maximal simultaneous contraction of both transverse abdominal muscle and levator ani muscle with lateral resistance added to both knees. [Results] The thicknesses of transverse abdominal muscle during maximal simultaneous contraction and maximal simultaneous contraction with resistance were greater than during the resting state. [Conclusion] The muscle output during simultaneous contraction and resistance movement were larger than that of each individual muscle.
Low prevalence of abdominal aortic aneurysm in the Seychelles population aged 50 to 65 years.
Yerly, Patrick; Madeleine, George; Riesen, Walter; Bovet, Pascal
2013-03-01
The prevalence of abdominal aortic aneurysm (AAA) and its risk factors are well known in Western countries but few data are available from low- and middle- income countries. We are not aware of systematically collected population- based data on AAA in the African region. We evaluated the prevalence of AAA in a population- based cardiovascular survey conducted in the Republic of Seychelles in 2004 (Indian Ocean, African region). Among the 353 participants aged 50 to 64 years and screened with ultrasound, the prevalence of AAA was 0.3% (95% CI: 0- 0.9) and the prevalence of ectatic dilatations of the abdominal aorta was 1.5% (95% CI: 0.2- 2.8). The prevalence of AAA in the general population seemed lower in Seychelles than in Western countries, despite a high prevalence in Seychelles of risk factors of AAA, such as smoking (in men), high blood pressure and hypercholesterolaemia.
Ulman, I; Avanoğlu, A; Ozcan, C; Demircan, M; Ozok, G; Erdener, A
1996-07-01
The present trend towards conservative management of hemodynamically stable pediatric trauma patients may be increasing the risk of delay in the diagnosis of traumatic hollow viscus perforations (HVP). The purpose of this study is to determine whether there is a delay in the diagnosis of HVP because of expectant management. A survey of factors leading to diagnostic delay was also made and the value of current diagnostic tools were reevaluated. In 1,283 trauma admissions between 1980-1994, 34 patients were operated for HVP caused by blunt abdominal trauma. Sites of perforation were; stomach (four), duodenum (five), jejunum (12), ileum (nine), and jejunum/ileum (four). Signs of peritoneal irritation were positive in 32 of 34 patients. There was free air in only six of 24 abdominal roentgenograms. Free peritoneal fluid without solid organ injury was detected in only four out of 13 patients with ultrasound. Peritoneal lavage was diagnostic in eight of nine patients. Time from admission to operating room averaged 24 +/- 4.1 (mean +/- standard deviation) hours. Eleven patients died after the operation mostly because of accompanying head injury. Only two of the deaths were the result of sepsis originating from the perforated bowel. There is an apparent delay in the diagnosis of traumatic HVP in this series. Signs of peritoneal irritation are the most consistent findings of HVP after blunt abdominal trauma in children. Persistence of abdominal signs indicates peritoneal lavage, which has a high diagnostic sensitivity for HVP compared to other diagnostic modalities.
2012-01-01
The glenohumeral joint is a spherical articulation with a remarkable range of motion in several planes and decreased stability. The maintenance of joint stability is influenced by the functioning of specific muscle groups in the shoulder region, a complex system of ligaments reinforcing the joint capsule, and the labrum which augments the glenoid fossa. Lesions of the aforementioned structures require accurate diagnosis prior to a decision for operative treatment. Ultrasound is one of the imaging methods that has been widely used in the assessment of various shoulder pathologies. In the author opinion, this imaging modality may also be applied for the evaluation of labral tears. Being attached along the glenoid rim, the labrum forms a collar deepening the glenoid fossa thus increasing area of its contact with the head of the humerus. To better describe the location of lesions, the glenoid labrum is usually divided into certain zones. Most of them may be visualized sonographically. The US examination of the posterior labrum can be performed during evaluation of the infraspinatus and teres minor muscles. The anterior labrum along with capsulolabral complex is seen at the glenoid edge under the subscapularis tendon. Sonographic examination of the inferior labrum is best performed using axillar approach. The superior labrum is only partially available for US examination. A crucial part of the sonographic assessment of the labrum is the dynamic examination during rotation of the upper extremity. The paper presents normal sonographic anatomy of the glenoid labrum and technique of the examination. PMID:26673515
Vascular ultrasound; Peripheral vascular ultrasound ... A duplex ultrasound combines: Traditional ultrasound: This uses sound waves that bounce off blood vessels to create pictures. Doppler ultrasound: This ...
Predictors of "occult" intra-abdominal injuries in blunt trauma patients.
Parreira, José Gustavo; Malpaga, Juliano Mangini Dias; Olliari, Camilla Bilac; Perlingeiro, Jacqueline A G; Soldá, Silvia C; Assef, José Cesar
2015-01-01
to assess predictors of intra-abdominal injuries in blunt trauma patients admitted without abdominal pain or abnormalities on the abdomen physical examination. We conducted a retrospective analysis of trauma registry data, including adult blunt trauma patients admitted from 2008 to 2010 who sustained no abdominal pain or abnormalities on physical examination of the abdomen at admission and were submitted to computed tomography of the abdomen and/or exploratory laparotomy. Patients were assigned into: Group 1 (with intra-abdominal injuries) or Group 2 (without intra-abdominal injuries). Variables were compared between groups to identify those significantly associated with the presence of intra-abdominal injuries, adopting p<0.05 as significant. Subsequently, the variables with p<0.20 on bivariate analysis were selected to create a logistic regression model using the forward stepwise method. A total of 268 cases met the inclusion criteria. Patients in Group I were characterized as having significantly (p<0.05) lower mean AIS score for the head segment (1.0 ± 1.4 vs. 1.8 ± 1.9), as well as higher mean AIS thorax score (1.6 ± 1.7 vs. 0.9 ± 1.5) and ISS (25.7 ± 14.5 vs. 17,1 ± 13,1). The rate of abdominal injuries was significantly higher in run-over pedestrians (37.3%) and in motorcyclists (36.0%) (p<0.001). The resultant logistic regression model provided 73.5% accuracy for identifying abdominal injuries. The variables included were: motorcyclist accident as trauma mechanism (p<0.001 - OR 5.51; 95%CI 2.40-12.64), presence of rib fractures (p<0.003 - OR 3.00; 95%CI 1.47-6.14), run-over pedestrian as trauma mechanism (p=0.008 - OR 2.85; 95%CI 1.13-6.22) and abnormal neurological physical exam at admission (p=0.015 - OR 0.44; 95%CI 0.22-0.85). Intra-abdominal injuries were predominantly associated with trauma mechanism and presence of chest injuries.
Management of complex abdominal wall defects associated with penetrating abdominal trauma.
Arul, G Suren; Sonka, B J; Lundy, J B; Rickard, R F; Jeffery, S L A
2015-03-01
The paradigm of Damage Control Surgery (DCS) has radically improved the management of abdominal trauma, but less well described are the options for managing the abdominal wall itself in an austere environment. This article describes a series of patients with complex abdominal wall problems managed at the UK-led Role 3 Medical Treatment Facility (MTF) in Camp Bastion, Afghanistan. Contemporaneous review of a series of patients with complex abdominal wall injuries who presented to the Role 3 MTF between July and November 2012. Five patients with penetrating abdominal trauma associated with significant damage to the abdominal wall were included. All patients were managed using DCS principles, leaving the abdominal wall open at the end of the first procedure. Subsequent management of the abdominal wall was determined by a multidisciplinary team of general and plastic surgeons, intensivists and specialist nurses. The principles of management identified included minimising tissue loss on initial laparotomy by joining adjacent wounds and marginal debridement of dead tissue; contraction of the abdominal wall was minimised by using topical negative pressure dressing and dermal-holding sutures. Definitive closure was timed to allow oedema to settle and sepsis to be controlled. Closure techniques include delayed primary closure with traction sutures, components separation, and mesh closure with skin grafting. A daily multidisciplinary team discussion was invaluable for optimal decision making regarding the most appropriate means of abdominal closure. Dermal-holding sutures were particularly useful in preventing myostatic contraction of the abdominal wall. A simple flow chart was developed to aid decision making in these patients. This flow chart may prove especially useful in a resource-limited environment in which returning months or years later for closure of a large ventral hernia may not be possible. Published by the BMJ Publishing Group Limited. For permission to use
Effects of aerobic exercise associated with abdominal microcurrent: a preliminary study.
Noites, Andreia; Nunes, Rita; Gouveia, Ana Isabel; Mota, Alexandra; Melo, Cristina; Viera, Ágata; Adubeiro, Nuno; Bastos, José Mesquita
2015-04-01
To analyze the short- and long-term effects of microcurrent used with aerobic exercise on abdominal fat (visceral and subcutaneous). Forty-two female students from a university population were randomly assigned into five group: intervention group (IG) 1 (n=9), IG2 (n=9), IG3 (n=7), IG4 (n=8), and placebo group (PG) (n=9). An intervention program of 10 sessions encompassing microcurrent and aerobic exercise (performed with a cycloergometer) was applied in all groups, with slightly differences between them. In IG1 and IG2, microcurrent with transcutaneous electrodes was applied, with different frequency values; 30-minute exercise on the cycloergometer was subsequently performed. IG3 used the same protocol as IG1 but with different electrodes (percutaneous), while in IG4 the microcurrent was applied simultaneously with the cycloergometer exercise. Finally, the PG used the IG1 protocol but with the microcurrent device switched off. All groups were evaluated through ultrasound and abdominal perimeter measurement for visceral and subcutaneous abdominal fat assessment; through calipers for skinfolds measurement; through bioimpedance to evaluate weight, fat mass percentage, and muscular mass; and through blood analyses to measure cholesterol, triglyceride, and glucose levels. After intervention sessions, visceral fat decreased significantly in IG1 compared with the PG. Subcutaneous fat was reduced significantly in all groups compared with the PG. After 4 weeks, almost all results were maintained. The addition of microcurrent to aerobic exercise may reduce fat more than does aerobic exercise alone.
Goal-directed ultrasound in the detection of long-bone fractures
NASA Technical Reports Server (NTRS)
Marshburn, Thomas H.; Legome, Eric; Sargsyan, Ashot; Li, Shannon Melton James; Noble, Vicki A.; Dulchavsky, Scott A.; Sims, Carrie; Robinson, David
2004-01-01
BACKGROUND: New portable ultrasound (US) systems are capable of detecting fractures in the remote setting. However, the accuracy of ultrasound by physicians with minimal ultrasound training is unknown. METHODS: After one hour of standardized training, physicians with minimal US experience clinically evaluated patients presenting with pain and trauma to the upper arm or leg. The investigators then performed a long-bone US evaluation, recording their impression of fracture presence or absence. Results of the examination were compared with routine plain or computer aided radiography (CT). RESULTS: 58 patients were examined. The sensitivity and specificity of US were 92.9% and 83.3%, and of the physical examination were 78.6% and 90.0%, respectively. US provided improved sensitivity with less specificity compared with physical examination in the detection of fractures in long bones. CONCLUSION: Ultrasound scans by minimally trained clinicians may be used to rule out a long-bone fracture in patients with a medium to low probability of fracture.
The value of plain abdominal radiographs in management of abdominal emergencies in Luth.
Ashindoitiang, J A; Atoyebi, A O; Arogundade, R A
2008-01-01
The plain abdominal x-ray is still the first imaging modality in diagnosis of acute abdomen. The aim of this study was to find the value of plain abdominal x-ray in the management of abdominal emergencies seen in Lagos university teaching hospital. The accurate diagnosis of the cause of acute abdominal pain is one of the most challenging undertakings in emergency medicine. This is due to overlapping of clinical presentation and non-specific findings of physical and even laboratory data of the multifarious causes. Plain abdominal radiography is one investigation that can be obtained readily and within a short period of time to help the physician arrive at a correct diagnosis The relevance of plain abdominal radiography was therefore evaluated in the management of abdominal emergencies seen in Lagos over a 12 month period (April 2002 to March 2003). A prospective study of 100 consecutively presenting patients with acute abdominal conditions treated by the general surgical unit of Lagos University Teaching Hospital was undertaken. All patients had supine and erect abdominal x-ray before any therapeutic intervention was undertaken. The diagnostic features of the plain films were compared with final diagnosis to determine the usefulness of the plain x-ray There were 54 males and 46 females (M:F 1.2:1). Twenty-four percent of the patients had intestinal obstruction, 20% perforated typhoid enteritis; gunshot injuries and generalized peritonitis each occurred in 13%, blunt abdominal trauma in 12%, while 8% and 10% had acute appendicitis and perforated peptic ulcer disease respectively. Of 100 patients studied, 54% had plain abdominal radiographs that showed positive diagnostic features. Plain abdominal radiograph showed high sensitivity in patients with intestinal obstruction 100% and perforated peptic ulcer 90% but was less sensitive in patients with perforated typhoid, acute appendicitis, and blunt abdominal trauma and generalized peritonitis. In conclusion, this study
Antoszewska, Magdalena
2013-05-01
Abdominal aortic aneurysms and abdominal hernias become an important health problems of our times. Abdominal aortic aneurysm and its rupture is one of the most dangerous fact in vascular surgery. There are some theories pointing to a multifactoral genesis of these kinds of diseases, all of them assume the attenuation of abdominal fascia and abdominal aortic wall. The density and continuity of these structures depend on collagen and elastic fibers structure. Reducing the strength of the fibers may be due to changes in the extracellular matrix (ECM) by the proteolytic enzymes-matrix metalloproteinases (MMPs) that degrade extracellular matrix proteins. These enzymes play an important role in the development of many disease: malignant tumors (colon, breast, lung, pancreas), cardiovascular disease (myocardial infarction, ischemia-reperfusion injury), connective tissue diseases (Ehler-Danlos Syndrome, Marfan's Syndrome), complications of diabetes (retinopathy, nephropathy). One of the most important is matrix metalloproteinase-2 (MMP-2). The aim of the study was an estimation of the MMP-2 blood levels in patients with abdominal aortic aneurysm and primary abdominal hernia, and in patients with only abdominal aortic aneurysm. The study involved 88 patients aged 42 to 89 years, including 75 men and 13 women. Patients were divided into two groups: patients with abdominal aortic aneurysm and primary abdominal hernia (45 persons, representing 51.1% of all group) and patients with only abdominal aortic aneurysm (43 persons, representing 48,9% of all group). It was a statistically significant increase in MMP-2 blood levels in patients with abdominal aortic aneurysm and primary abdominal hernia compared to patients with only abdominal aortic aneurysm. It was a statistically significant increase in the prevalence of POCHP in patients with only abdominal aortic aneurysm compared to patients with abdominal aortic aneurysm and primary abdominal hernia. Statistically significant
Okuwaki, Kosuke; Kida, Mitsuhiro; Masutani, Hironori; Yamauchi, Hiroshi; Katagiri, Hiroyuki; Mikami, Tetuo; Miyazawa, Shiro; Iwai, Tomohisa; Takezawa, Miyoko; Imaizumi, Hiroshi; Koizumi, Wasaburo
2013-01-01
Primary perivascular epithelioid cell tumors (PEComas) of the pancreas are extremely rare. We herein report our experience with a patient who had a primary PEComa of the pancreas that was diagnosed by the preoperative histopathological examination of a biopsy specimen obtained by endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA). The patient was a 43-year-old woman whose chief complaint was abdominal pain. Imaging studies revealed a pancreatic tumor. Gastrointestinal stromal tumor (GIST), solid pseudopapillary tumor and neuroendocrine tumor were considered in the differential diagnosis. A histopathological examination of a specimen of the tumor obtained using EUS-FNA showed spindle-shaped tumor cells with enlarged nuclei and eosinophilic cytoplasm. The tumor cells proliferated in a sheet-like fashion and stained positive for the melanoma-associated antigen HMB-45. A PEComa was thus diagnosed. If an adequate tumor specimen can be obtained using EUS-FNA, immunostaining may facilitate the diagnosis of extremely rare diseases and therefore assist in deciding the treatment policy.
Relationships of occupational and non-occupational physical activity to abdominal obesity.
Steeves, J A; Bassett, D R; Thompson, D L; Fitzhugh, E C
2012-01-01
Physically active occupations may protect against the risk of abdominal obesity. This study assessed the interaction between non-occupational physical activity (NOA) (leisure-time, transport and domestic activity) and occupational activity (OA) in relation to abdominal obesity. A total of 3539 adults over the age of 20, with no work limitations, employed in one of the 17 occupations classified as low OA (LOA) or high OA (HOA) were identified in the 1999-2004 National Health and Nutrition Examination Survey. Waist circumference (WC) was used to categorize individuals into either non-obese or abdominally obese (WC>88 cm in women and >102 cm in men) categories. NOA was divided into three categories based upon physical activity guidelines: (1) no NOA; (2) insufficient NOA; and (3) sufficient NOA. Logistic regression was used to examine possible associations between NOA, OA and abdominal obesity. In those who are sedentary outside of work, a high-activity occupation reduces the odds risk ratio of being categorized with abdominal obesity to 0.37 in comparison with those who work in low-activity occupations. For people working in low-activity occupations, there was a clear association with activity outside of work and the odds risk ratio of being categorized with abdominal obesity. In these adults, a reduced odds ratio was found only among those who met the physical activity guidelines through NOA (odds ratio=0.55; 95% confidence interval (CI)=0.40-0.75). HOA is associated with a reduced risk of abdominal obesity. Thus, it is important to include OA in studies seeking to understand the association between physical activity and abdominal adiposity.
Alves, João Guilherme; Vasconcelos, Sarita Amorim; de Almeida, Tais Sá; Lages, Raquel; Just, Eduardo
2015-01-01
A rapid catch-up growth in very low birth weight has been associated both with a higher height growth and a higher risk to metabolic disturbances, including insulin resistance and its consequences. Abdominal fat distribution in early postnatal life may play a role in these outcomes and can help in addressing this neonatal dilemma. This study aimed to compare abdominal fat distribution among very low birth weight (VLBW) children with and without rapid catch-up growth. A cohort study followed 86 VLBW (<1500) children born in Brazil, during the first 3 years of life. Rapid catch-up growth was considered as an increased in length >2 Z score during the first year of life. Abdominal subcutaneous and preperitoneal fat thickness was determined by ultrasound. χ²-Test and Student's t-test were used to compare the groups. A total of 79 VLBW children completed the study, of whom 22 (27.8%) showed rapid catch-up growth. Abdominal subcutaneous and preperitoneal fat thickness showed no differences among children with or without rapid catch-up growth at 3.3 mm vs. 3.8 mm, respectively (p=0.79) and 4.0 mm vs. 4.0 mm (p=0.55), respectively. VLBW children with rapid catch-up growth were also taller. Rapid catch-up growth during the first year of life in VLBW children does not seem to change abdominal fat distribution until the third year of life.
Wanitphakdeedecha, Rungsima; Iamphonrat, Thanawan; Thanomkitti, Kanchalit; Lektrakul, Nittaya; Manuskiatti, Woraphong
2015-01-01
Cellulite is a frequent skin condition for which treatment remains a challenge. A wide variety of treatments are available but most procedures offer suboptimal clinical effect and/or delayed therapeutic outcome. Only few therapeutic options have proven efficacy in the treatment of cellulite. To determine the efficacy and the safety profiles of radiofrequency and dynamic muscle activation technology in treatment of abdominal cellulite and circumference reduction. Twenty-five females with abdominal cellulite received 6 weekly radiofrequency and dynamic muscle activation treatments. Treatment areas included the abdomen and both sides of flanks. Subjects were evaluated using standardized photographs, and measurements of body weight and abdominal circumference at baseline, before every treatment visit, and 1 week and four weeks after the final treatment. Subcutaneous tissue thickness was recorded by ultrasound at baseline and 4 weeks after completion of treatment protocol. Physicians' evaluation and patient's satisfaction of clinical improvement were also measured. All subjects completed the treatment protocol and attended every follow-up visits. There was significant abdominal circumference reduction of 2.96 and 2.52 cm at 1-, and 4-week follow-up visits (p < 0.05), respectively. At four weeks after the last treatment, the average circumferential reduction was sustained. Most of the patients were rated to have 25-49% improvement at 5th treatment, and 1- and 4-week follow-up visits. Ninety-two percent of the patients were satisfied with the treatment outcome. Radiofrequency provided beneficial effects on the reduction of abdomen and cellulite appearance. The benefit of muscle activation is yet to be determined.
Impact of Music in Reducing Patient Anxiety During Pediatric Ultrasound
Kesselman, Andrew; Bergen, Michael; Stefanov, Dimitre; Goldfisher, Rachelle; Amodio, John
2016-01-01
The use of noninvasive ultrasound examinations can potentially result in significant anxiety in the pediatric population. The purpose of this study was to assess the influence of music during pediatric ultrasound examinations to reduce anxiety measured by heart rate. A total of 44 patients were recruited; 21 controls and 23 experimental. Each participant was randomized to either music or no music (control) after parental consent was obtained. Pulse oximeters were used to monitor heart rate at 15 second intervals for a total of 1 minute, with mean values calculated prior to entering the procedure room, during the middle of the procedure, and after the procedure was completed. The total scan time was determined from the initial image acquisition until the last image recorded by the ultrasound technologist. At the completion of each procedure, the ultrasound technologist scored the ease of performance for the scan on a subjective scale of 1-10 based on prior experience. When utilizing music during pediatric ultrasounds examinations, our study demonstrated significantly decreased heart rate variability from pre-procedural to post-procedural periods. There was no statistical significant difference in total scan time or ultrasound technologist scoring between the two groups. This study demonstrates that music is an inexpensive and effective means of reducing anxiety during pediatric ultrasound as indicated by heart rate. PMID:27114817
The Effect of VASER Abdominal Liposuction on Metabolic Profile in Overweight Males
Gibas-Dorna, Magdalena; Szulińska, Monika; Turkowski, Piotr; Kupsz, Justyna; Sowińska, Anna; Mikrut, Kinga; Bernatek, Małgorzata; Piatek, Jacek
2016-01-01
The aim of the current study was to examine the liposuction-induced metabolic changes with regard to release of major adipokines and insulin sensitivity in overweight male patients. Seventeen overweight male patients aged 37.15 ± 9.60 years (6 with diabetes type 2, 11 without comorbidities) and 10 age-matched healthy lean controls were enrolled in the study. Using Vibration Amplification of Sound Energy at Resonance System, ultrasound assisted liposuction was applied onto the deep layers of abdominal subcutaneous adipose tissue. The mean volume supranatant fat was 2208 ± 562 ml. To eliminate the confounding effects of postsurgical inflammation and to evaluate delayed metabolic effects, fasting blood was collected on the day of liposuction, within 1 to 2 months and more than 6 months after surgery. Serum leptin, soluble receptor for leptin, adiponectin, insulin, and glucose concentrations were tested and insulin sensitivity was calculated using updated model Homeostasis Model Assessment 2. Both treatment groups (diabetic and nondiabetic patients) experienced similar postsurgical weight reduction with concomitant lowering of body mass index value at 1 to 2 months follow-up, which was sustained after 6 months from surgery. Improvement in insulin sensitivity at 1 to 2 months follow-up was observed (p = .017 and p = .002, for diabetics and nondiabetics, respectively) and this change persisted over the next 4 months. At the same time, no significant changes in adipokines and soluble leptin receptor were found. These data demonstrate that in terms of metabolic consequences, Vibration Amplification of Sound Energy at Resonance abdominal liposuction might have beneficial effects in overweight diabetic and nondiabetic males by improving their insulin sensitivity. PMID:27756865
The Effect of VASER Abdominal Liposuction on Metabolic Profile in Overweight Males.
Gibas-Dorna, Magdalena; Szulińska, Monika; Turkowski, Piotr; Kupsz, Justyna; Sowińska, Anna; Mikrut, Kinga; Bernatek, Małgorzata; Piatek, Jacek
2017-03-01
The aim of the current study was to examine the liposuction-induced metabolic changes with regard to release of major adipokines and insulin sensitivity in overweight male patients. Seventeen overweight male patients aged 37.15 ± 9.60 years (6 with diabetes type 2, 11 without comorbidities) and 10 age-matched healthy lean controls were enrolled in the study. Using Vibration Amplification of Sound Energy at Resonance System, ultrasound assisted liposuction was applied onto the deep layers of abdominal subcutaneous adipose tissue. The mean volume supranatant fat was 2208 ± 562 ml. To eliminate the confounding effects of postsurgical inflammation and to evaluate delayed metabolic effects, fasting blood was collected on the day of liposuction, within 1 to 2 months and more than 6 months after surgery. Serum leptin, soluble receptor for leptin, adiponectin, insulin, and glucose concentrations were tested and insulin sensitivity was calculated using updated model Homeostasis Model Assessment 2. Both treatment groups (diabetic and nondiabetic patients) experienced similar postsurgical weight reduction with concomitant lowering of body mass index value at 1 to 2 months follow-up, which was sustained after 6 months from surgery. Improvement in insulin sensitivity at 1 to 2 months follow-up was observed ( p = .017 and p = .002, for diabetics and nondiabetics, respectively) and this change persisted over the next 4 months. At the same time, no significant changes in adipokines and soluble leptin receptor were found. These data demonstrate that in terms of metabolic consequences, Vibration Amplification of Sound Energy at Resonance abdominal liposuction might have beneficial effects in overweight diabetic and nondiabetic males by improving their insulin sensitivity.
Comparison of Thermal Safety Practice Guidelines for Diagnostic Ultrasound Exposures.
Harris, Gerald R; Church, Charles C; Dalecki, Diane; Ziskin, Marvin C; Bagley, Jennifer E
2016-02-01
This article examines the historical evolution of various practice guidelines designed to minimize the possibility of thermal injury during a diagnostic ultrasound examination, including those published by the American Institute of Ultrasound in Medicine, British Medical Ultrasound Society and Health Canada. The guidelines for prenatal/neonatal examinations are in general agreement, but significant differences were found for postnatal exposures. We propose sets of thermal index versus exposure time for these examination categories below which there is reasonable assurance that an examination can be conducted without risk of producing an adverse thermal effect under any scanning conditions. If it is necessary to exceed these guidelines, the occurrence of an adverse thermal event is still unlikely in most situations because of mitigating factors such as transducer movement and perfusion, but the general principle of "as low as reasonably achievable" should be followed. Some limitations of the biological effects studies underpinning the guidelines also are discussed briefly. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
[A commonly seen cause of abdominal pain: abdominal cutaneous nerve entrapment syndrome].
Solmaz, Ilker; Talay, Mustafa; Tekindur, Şükrü; Kurt, Ercan
2012-01-01
Although abdominal cutaneous nerve entrapment syndrome (ACNES) is accepted as a rare condition, it is a syndrome that should be diagnosed more commonly when the clinical signs cannot explain the cause of abdominal pain. Abdominal pain is commonly considered by physicians to be based on intra-abdominal causes. Consequently, redundant tests and consultations are requested for these patients, and unnecessary surgical procedures may be applied. Patients with this type of pain are consulted to many clinics, and because their definitive diagnoses cannot be achieved, they are assessed as psychiatric patients. Actually, a common cause of abdominal wall pain is nerve entrapment on the lateral edge of the rectus abdominis muscle. In this paper, we would like to share information about the diagnosis and treatment of a patient who, prior to presenting to us, had applied to different clinics for chronic abdominal pain and had undergone many tests and consultations; abdominal surgery was eventually decided.
Koski, J M; Saarakkala, S; Helle, M; Hakulinen, U; Heikkinen, J O; Hermunen, H
2006-12-01
To examine the validity of power Doppler ultrasound imaging to identify synovitis, using histopathology as gold standard, and to assess the performance of ultrasound equipments. 44 synovial sites in small and large joints, bursae and tendon sheaths were depicted with ultrasound. A synovial biopsy was performed on the site depicted and a synovial sample was taken for histopathological evaluation. The performance of three ultrasound devices was tested using flow phantoms. A positive Doppler signal was detected in 29 of 35 (83%) of the patients with active histological inflammation. In eight additional samples, histological examination showed other pathological synovial findings and a Doppler signal was detected in five of them. No significant correlation was found between the amount of Doppler signal and histological synovitis score (r = 0.239, p = NS). The amount of subsynovial infiltration of polymorphonuclear leucocytes and surface fibrin correlated significantly with the amount of power Doppler signal: r = 0.397 (p<0.01) and 0.328 (p<0.05), respectively. The ultrasound devices differed in showing the smallest detectable flow. A negative Doppler signal does not exclude the possibility of synovitis. A positive Doppler signal in the synovium is an indicator of an active synovial inflammation in patients. A Doppler signal does not correlate with the extent of the inflammation and it can also be seen in other synovial reactions. It is important that the quality measurements of ultrasound devices are reported, because the results should be evaluated against the quality of the device used.
NASA Astrophysics Data System (ADS)
Wittek, Andreas; Blase, Christopher; Derwich, Wojciech; Schmitz-Rixen, Thomas; Fritzen, Claus-Peter
2017-06-01
Abdominal aortic aneurysms (AAA) are a degenerative disease of the human aortic wall that may lead to weakening and eventually rupture of the wall with high mortality rates. Since the currently established criterion for surgical or endovascular treatment of the disease is imprecise in the individual case and treatment is not free of complications, the need for additional patient-individual biomarkers for short-term AAA rupture risk as basis for improved clinical decision making. Time resolved 3D ultrasound combined with speckle tracking algorithms is a novel non-invasive medical imaging technique that provides full-field displacement and strain measurements of aortic and aneurysmal wall motion. This is patient-individual information that has not been used so far to assess wall strength and rupture risk. The current study uses simple statistical indices of the heterogeneous spatial distribution of in-plane strain components as biomarkers for the pathological state of the aortic and aneurysmal wall. The pathophysiological rationale behind this approach are the known changes in microstructural composition of the aortic wall with progression of AAA development that results in increased stiffening and heterogeneity of the walls mechanical properties and in decreased wall strength. In a comparative analysis of the aortic wall motion of young volunteers without known cardiovascular diseases, aged arteriosclerotic patients without AAA, and AAA patients, mean values of all in-plane strain components were significantly reduced, and the heterogeneity of circumferential strain was significantly increased in the AAA group compared to both other groups. The capacity of the proposed method to differentiate between wall motion of aged, arteriosclerotic patients and AAA patients is a promising step towards a new method for in vivo assessment of AAA wall strength or stratification of AAA rupture risk as basis for improved clinical decision making on surgical or endovascular
Complete occlusion after blunt injury to the abdominal aorta.
Meghoo, Colin A L; Gonzalez, Ernest A; Tyroch, Alan H; Wohltmann, Christopher D
2003-10-01
Injury to the abdominal aorta after blunt trauma is uncommon. When this injury results in complete vessel occlusion, the presentation is dramatic. Timely intervention is essential. After a case report, we examined all reported cases of complete occlusion after blunt injury to the abdominal aorta and reviewed the cause, presentation, and management of this injury. Complete vessel occlusion arises from intimal injury. The most frequent mechanism is compression from a seat belt or steering wheel during a motor vehicle crash. Patients present with absent femoral and distal pulses in association with lower extremity neuropathy. Intervention commonly involves bypass grafting of the abdominal aorta. Complete occlusion after blunt trauma to the abdominal aorta is rare. Neurologic deficits most commonly arise from peripheral nerve ischemia. Reperfusion within 6 hours confers a greater chance of limb salvage and neurologic recovery.
The Effects of Ultrasound on Biological Systems: Site
NASA Astrophysics Data System (ADS)
El-Karmi, Anan M.
Earlier studies (Dinno et al., Ultrasound Med. Biol. 15:461 -470; 1989) demonstrated that ultrasound at therapeutic intensities causes large increases in total conductance (G_{rm t}) of frog skin. These changes were attributed to non-thermal mechanisms, primarily, cavitation. In this study, the site(s) and mechanism(s) of action of ultrasound for the increase in G_{rm t} were examined. The reversible changes in G_{rm t } and sodium current were monitored in real time as a function of ultrasound exposure. Amiloride, a sodium channel blocker, was used to differentiate between cellular (G_{rm c}) and paracellular (G_{rm s}) pathways in the presence and absence of ultrasound. No significant changes were detected in G_ {rm c}. However, changes in G _{rm s} were significant. These results demonstrate that most of the increase in G _{rm t} due to ultrasound is taking place in the paracellular pathways. Sodium channels were not significantly affected by ultrasound. Thus, the changes in G_{rm c} are not specific. The effects of ultrasound were examined in the presence of radical scavengers and antioxidants. The increase in G_{rm t} due to ultrasound was significantly minimized in the presence of cystamine, cysteamine, and sodium ascorbate. This demonstrates that free radicals and other reactive species generated by cavitation are causing the increase in G_ {rm t}, possibly by acting from inside the cells. Radical scavengers and antioxidants are providing protection from oxidative damage but are not involved in the recovery of G_{ rm t} towards steady state values after sonication. The role of Ca^{2+} in the effects of ultrasound was examined since many of the cellular reactions involved in tissue recovery are dependent on the intracellular availability of free Ca^{2+}. The percentage increase in G_{rm t} in the presence of Ca^{2+} was larger than in its absence (140% vs. 27%). The time constant for G_{rm t} to return to steady state was longer in calcium-free solutions (122
Transversus abdominal plane (TAP) block for postoperative pain management: a review.
Jakobsson, Jan; Wickerts, Liselott; Forsberg, Sune; Ledin, Gustaf
2015-01-01
Transversus abdominal plane (TAP) block has a long history and there is currently extensive clinical experience around TAP blocks. The aim of this review is to provide a summary of the present evidence on the effects of TAP block and to provide suggestions for further studies. There are several approaches to performing abdominal wall blocks, with the rapid implementation of ultrasound-guided technique facilitating a major difference in TAP block performance. During surgery, an abdominal wall block may also be applied by the surgeon from inside the abdominal cavity. Today, there are more than 11 meta-analyses providing a compiled evidence base around the effects of TAP block. These analyses include different procedures, different techniques of TAP block administration and, importantly, they compare the TAP block with a variety of alternative analgesic regimes. The effects of TAP block during laparoscopic cholecystectomy seem to be equivalent to local infiltration analgesia and also seem to be beneficial during laparoscopic colon resection. The effects of TAP are more pronounced when it is provided prior to surgery and these effects are local anaesthesia dose-dependent. TAP block seems an interesting alternative in patients with, for example, severe obesity where epidural or spinal anaesthesia/analgesia is technically difficult and/or poses a risk. There is an obvious need for further high-quality studies comparing TAP block prior to surgery with local infiltration analgesia, single-shot spinal analgesia, and epidural analgesia. These studies should be procedure-specific and the effects should be evaluated, both regarding short-term pain and analgesic requirement and also including the effects on postoperative nausea and vomiting, recovery of bowel function, ambulation, discharge, and protracted recovery outcomes (assessed by e.g., postoperative quality of recovery scale).
Errors in the ultrasound diagnosis of the kidneys, ureters and urinary bladder
Wieczorek, Andrzej Paweł; Tyloch, Janusz F.
2013-01-01
The article presents the most frequent errors made in the ultrasound diagnosis of the urinary system. They usually result from improper technique of ultrasound examination or its erroneous interpretation. Such errors are frequent effects of insufficient experience of the ultrasonographer, inadequate class of the scanner, insufficient knowledge of its operation as well as of wrong preparation of patients, their constitution, severe condition and the lack of cooperation during the examination. The reasons for misinterpretations of ultrasound images of the urinary system may lie in a large polymorphism of the kidney (defects and developmental variants) and may result from improper access to the organ as well as from the presence of artefacts. Errors may also result from the lack of knowledge concerning clinical and laboratory data. Moreover, mistakes in ultrasound diagnosis of the urinary system are frequently related to the lack of knowledge of the management algorithms and diagnostic possibilities of other imaging modalities. The paper lists errors in ultrasound diagnosis of the urinary system divided into: errors resulting from improper technique of examination, artefacts caused by incorrect preparation of patients for the examination or their constitution and errors resulting from misinterpretation of ultrasound images of the kidneys (such as their number, size, fluid spaces, pathological lesions and others), ureters and urinary bladder. Each physician performing kidney or bladder ultrasound examination should possess the knowledge of the most frequent errors and their causes which might help to avoid them. PMID:26674139
Portable bladder ultrasound: an evidence-based analysis.
2006-01-01
The aim of this review was to assess the clinical utility of portable bladder ultrasound. TARGET POPULATION AND CONDITION Data from the National Population Health Survey indicate prevalence rates of urinary incontinence are 2.5% in women and 1.4 % in men in the general population. Prevalence of urinary incontinence is higher in women than men and prevalence increases with age. Identified risk factors for urinary incontinence include female gender, increasing age, urinary tract infections (UTI), poor mobility, dementia, smoking, obesity, consuming alcohol and caffeine beverages, physical activity, pregnancy, childbirth, forceps and vacuum-assisted births, episiotomy, abdominal resection for colorectal cancer, and hormone replacement therapy. For the purposes of this review, incontinence populations will be stratified into the following; the elderly, urology patients, postoperative patients, rehabilitation settings, and neurogenic bladder populations. Urinary incontinence is defined as any involuntary leakage of urine. Incontinence can be classified into diagnostic clinical types that are useful in planning evaluation and treatment. The major types of incontinence are stress (physical exertion), urge (overactive bladder), mixed (combined urge and stress urinary incontinence), reflex (neurological impairment of the central nervous system), overflow (leakage due to full bladder), continuous (urinary tract abnormalities), congenital incontinence, and transient incontinence (temporary incontinence). Postvoid residual (PVR) urine volume, which is the amount of urine in the bladder immediately after urination, represents an important component in continence assessment and bladder management to provide quantitative feedback to the patient and continence care team regarding the effectiveness of the voiding technique. Although there is no standardized definition of normal PVR urine volume, measurements greater than 100 mL to 150 mL are considered an indication for urinary
Pineda, L; Alcázar, J L; Caparrós, M; Mínguez, J A; Idoate, M A; Quiceno, H; Solórzano, J L; Jurado, M
2016-03-01
To compare diagnostic performance of preoperative transvaginal ultrasound (TVS) and intraoperative macroscopic examination for determining myometrial infiltration in women with low-risk endometrial cancer, and to estimate the agreement between the two methods. This was a single-center observational study comprising women with preoperative diagnosis of well- or moderately differentiated endometrioid carcinoma of the endometrium. All women underwent preoperative TVS by a single examiner. According to the examiner's subjective impression, myometrial infiltration was stated as ≥ 50% or < 50%. Surgical staging was performed in all cases. Intraoperative macroscopic examination of the removed uterus was performed by pathologists who were unaware of the ultrasound findings, and myometrial infiltration was stated as ≥ 50% or < 50%. Definitive histological diagnosis of myometrial infiltration was made by frozen section analysis and was used as the gold standard. Sensitivity and specificity with 95% CIs were calculated for TVS and intraoperative macroscopic inspection and compared using McNemar's test. Agreement between TVS and intraoperative macroscopic inspection was estimated using Cohen's kappa index (κ) and percentage of agreement. Of 209 eligible women, 152 were ultimately included. Mean (± SD) age was 60.9 ± 10.2 years, with a range of 32-91 years. Definitive histological diagnosis revealed that myometrial infiltration was < 50% in 114 women and ≥ 50% in 38 women. Sensitivity and specificity of TVS for detecting deep myometrial infiltration were 81.6% and 89.5%, respectively, whereas the respective values for intraoperative macroscopic examination were 78.9% and 90.4% (McNemar's test, P > 0.05 when comparing TVS and intraoperative macroscopic examination). Agreement between methods was moderate with κ = 0.54 (95% CI, 0.39-0.69) and percentage of agreement of 82%. Although the agreement between preoperative TVS and
Feeney, Daniel A; Ober, Christopher P; Snyder, Laura A; Hill, Sara A; Jessen, Carl R
2013-01-01
Peritoneal, mesenteric, and omental diseases are important causes of morbidity and mortality in humans and animals, although information in the veterinary literature is limited. The purposes of this retrospective study were to determine whether objectively applied ultrasound interpretive criteria are statistically useful in differentiating among cytologically defined normal, inflammatory, and neoplastic peritoneal conditions in dogs and cats. A second goal was to determine the cytologically interpretable yield on ultrasound-guided, fine-needle sampling of peritoneal, mesenteric, or omental structures. Sonographic criteria agreed upon by the authors were retrospectively and independently applied by two radiologists to the available ultrasound images without knowledge of the cytologic diagnosis and statistically compared to the ultrasound-guided, fine-needle aspiration cytologic interpretations. A total of 72 dogs and 49 cats with abdominal peritoneal, mesenteric, or omental (peritoneal) surface or effusive disease and 17 dogs and 3 cats with no cytologic evidence of inflammation or neoplasia were included. The optimized, ultrasound criteria-based statistical model created independently for each radiologist yielded an equation-based diagnostic category placement accuracy of 63.2-69.9% across the two involved radiologists. Regional organ-associated masses or nodules as well as aggregated bowel and peritoneal thickening were more associated with peritoneal neoplasia whereas localized, severely complex fluid collections were more associated with inflammatory peritoneal disease. The cytologically interpretable yield for ultrasound-guided fine-needle sampling was 72.3% with no difference between species, making this a worthwhile clinical procedure. © 2013 Veterinary Radiology & Ultrasound.
Optimizing sonication protocols for transthoracic focused ultrasound surgery
NASA Astrophysics Data System (ADS)
Gao, J.; Volovick, A.; Cao, R.; Nabi, G.; Cochran, S.; Melzer, A.; Huang, Z.
2012-11-01
During transthoracic focused ultrasound surgery (TFUS), the intervening ribs absorb and reflect the majority of the ultrasound energy excited by an acoustic source, resulting in pain, bone injuries and insufficient energy delivered to the target organs of liver, kidney, and pancreas. Localized hot spots may also exist at the interfaces between the ribs and soft tissue and in the highly absorptive regions such as the skin and connective tissue. The aims of this study were to clarify the effects of focal beam distortion and frequency-dependent rib heating in TFUS and to propose possible techniques to reduce the side-effects of rib heating and increase ultrasound efficacy. Frequency-dependent heating at the target and the ribs were estimated using finite element analysis (PZFlex, Weidlinger Associates Inc, USA) along with experimental verification on a range of different phantoms. The ratio of ultrasonic power density at the target and the ribs, the time-varying spatial distribution of temperature, and the ablated focus of each sonication were taken as key indicators to determine the optimal operating frequency. Comparison with a patient specific model was also made. TFUS seems to be useful to treat tumours that are small and near the surface of the abdominal organs. For targets deep inside these organs, severe attenuation of energy occurs, suggesting that purely ultrasound thermal ablation with advanced heating patterns will have limited effects in improving the treatment efficacy. Results demonstrate that the optimal ultrasound frequency is around 0.8 MHz for the configurations considered, but this may shift to higher frequencies with changes in the axial and lateral positions of the tumours relative to the ribs. To date, we have elucidated the most important effects and correlated these with idealised anatomical geometry. The changes in frequency and other techniques such as selection of excited element patterns in FUS arrays had some effect. However, more advanced
Focused abdominal sonography for trauma (FAST) in blunt paediatric abdominal trauma.
Faruque, Ahmad Vaqas; Qazi, Saqib Hamid; Khan, Muhammad Arif Mateen; Akhtar, Wassem; Majeed, Amina
2013-03-01
To evaluate the role of focussed abdominal sonography for trauma in blunt paediatric abdominal trauma patients, and to see if the role of computed tomography scan could be limited to only those cases in which sonography was positive. The retrospective study covered 10 years, from January 1,2000 to December 31,2009, and was conducted at the Department of Radiology and Department of Emergency Medicine, Aga Khan University Hospital, Karachi. It comprised cases of 174 children from birth to 14 years who had presented with blunt abdominal trauma and had focussed abdominal sonography for trauma done at the hospital. The findings were correlated with computed tomography scan of the abdomen and clinical follow-up. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of focussed abdominal sonography for trauma were calculated for blunt abdominal trauma. SPSS 17 was used for statistical analysis. Of the total 174 cases, 31 (17.81%) were later confirmed by abdominal scan. Of these 31 children, sonography had been positive in 29 (93.54%) children. In 21 (67.74%) of the 31 children, sonograpy had been true positive; 8 (25%) (8/31) were false positive; and 2 (6%) (2/31) were false negative. There were 6 (19.3%) children in which sonography was positive and converted to laparotomy. There was no significant difference on account of gender (p>0.356). Focussed abdominal sonography for trauma in the study had sensitivity of 91%, specificity of 95%, positive predictive value of 73%, and negative predictive value of 73% with accuracy of 94%. All patients who had negative sonography were discharged later, and had no complication on clinical follow-up. Focussed abdominal sonography for trauma is a fairly reliable mode to assess blunt abdominal trauma in children. It is a useful tool to pick high-grade solid and hollow viscous injury. The results suggest that the role of computed tomography scan can be limited to those cases in which focussed
Comparison of barium swallow and ultrasound in diagnosis of gastro-oesophageal reflux in children.
Naik, D R; Bolia, A; Moore, D J
1985-01-01
Fifty one infants and older children with suspected gastro-oesophageal reflux entered a study comparing the diagnostic accuracy of a standard barium swallow examination with that of ultrasound scanning. All children were examined by both techniques. In 40 cases there was unequivocal agreement between the examinations. Of the remaining patients, four had definite reflux by ultrasonic criteria but showed no evidence of reflux on barium swallow examination, four had positive findings on ultrasound but showed only minimal reflux on barium swallow, and one showed minimal reflux on ultrasound but had a negative barium meal result. In two children the ultrasound study was inconclusive. Ultrasound has an important role in the diagnosis and follow up of patients under the age of 5 years with gastro-oesophageal reflux. Images FIG 1 FIG 2 PMID:3924317
Ultrasound-guided pleural access.
Shojaee, Samira; Argento, A Christine
2014-12-01
Ultrasonography of the thorax has become a more recognized tool in pulmonary medicine, thanks to continuing clinical research that has proven its many valuable roles in the day-to-day management of pulmonary and pleural diseases. Ultrasound examination is a cost-effective imaging modality that permits the pulmonologist to obtain information about the pathologies in the thorax without the risk of exposure to ionizing radiation, providing the examiner with real-time and immediate results. Its ease of use and training along with its portability to the patient's bedside and accurate examination of the pleural space has allowed for safer pleural procedures such as thoracentesis, chest tube placement, tunneled pleural catheter placement, and medical thoracoscopy. In this review, we summarize the technique of chest ultrasonography, compare ultrasound to other frequently used thoracic imaging modalities, and focus on its use in obtaining pleural access while performing invasive pleural procedures. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Discriminant validity study of Achilles enthesis ultrasound.
Expósito Molinero, María Rosa; de Miguel Mendieta, Eugenio
2016-01-01
We want to know if the ultrasound examination of the Achilles tendon in spondyloarthritis is different compared to other rheumatic diseases. We studied 97 patients divided into five groups: rheumatoid arthritis, spondyloarthritis, gout, chondrocalcinosis and osteoarthritis, exploring six elementary lesions in 194 Achilles entheses examined. In our study the total index ultrasonographic Achilles is higher in spondyloarthritis with significant differences. The worst elementary spondyloarthritis lesions for discriminations against other pathologies were calcification. This study aims to demonstrate the discriminant validity of Achilles enthesitis observed by ultrasound in spondyloarthritis compared with other rheumatic diseases that may also have ultrasound abnormalities such enthesis level. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.
Droplets, Bubbles and Ultrasound Interactions.
Shpak, Oleksandr; Verweij, Martin; de Jong, Nico; Versluis, Michel
2016-01-01
The interaction of droplets and bubbles with ultrasound has been studied extensively in the last 25 years. Microbubbles are broadly used in diagnostic and therapeutic medical applications, for instance, as ultrasound contrast agents. They have a similar size as red blood cells, and thus are able to circulate within blood vessels. Perfluorocarbon liquid droplets can be a potential new generation of microbubble agents as ultrasound can trigger their conversion into gas bubbles. Prior to activation, they are at least five times smaller in diameter than the resulting bubbles. Together with the violent nature of the phase-transition, the droplets can be used for local drug delivery, embolotherapy, HIFU enhancement and tumor imaging. Here we explain the basics of bubble dynamics, described by the Rayleigh-Plesset equation, bubble resonance frequency, damping and quality factor. We show the elegant calculation of the above characteristics for the case of small amplitude oscillations by linearizing the equations. The effect and importance of a bubble coating and effective surface tension are also discussed. We give the main characteristics of the power spectrum of bubble oscillations. Preceding bubble dynamics, ultrasound propagation is introduced. We explain the speed of sound, nonlinearity and attenuation terms. We examine bubble ultrasound scattering and how it depends on the wave-shape of the incident wave. Finally, we introduce droplet interaction with ultrasound. We elucidate the ultrasound-focusing concept within a droplets sphere, droplet shaking due to media compressibility and droplet phase-conversion dynamics.
The utility of ultrasound in patients with melanoma.
Uren, Roger F; Sanki, Amira; Thompson, John F
2007-11-01
The highest quality gray-scale ultrasound images are obtained with high-frequency transducers; however, such high frequencies do not penetrate more than a few centimeters into body tissue. Fortunately, in patients with melanoma, the structures of interest are close to the skin surface, making them ideal targets for examination with high-resolution ultrasound. These include primary cutaneous melanomas, uveal melanomas and the regional lymph nodes draining the skin that lie in the axilla, groin, neck and other locations. Although ultrasound study of primary melanomas arising in the skin and eye has provided some insights, a major role for ultrasound has evolved recently, to provide early detection of metastatic melanoma in regional lymph nodes. Ultrasound is clearly superior to clinical palpation of the nodes during follow-up and, when combined with guided fine-needle biopsy, allows the earliest possible surgical intervention for regional nodal metastases. In the future the use of ultrasound contrast agents may improve the sensitivity of ultrasound in the detection of very small metastatic deposits.
Maconi, G.; Bolzacchini, E.; Radice, E.; Marzocchi, M.; Badini, M.
2012-01-01
Background and aims Intestinal gas is a frequent cause of poor visualization during gastrointestinal ultrasound (US). The enzyme alpha-galactosidase may reduce intestinal gas production, thereby improving abdominal US visualization. We compared the efficacies of alpha-galactosidase and active charcoal in improving US visualization in patients with previous unsatisfactory abdominal US scans caused by excessive intestinal gas. Materials and methods: 45 patients with poor visualization of at least one target organ: pancreas, hepatic lobes (score 0–2) or common bile duct (CBD) (score 0–1) were enrolled in a prospective randomized, crossover, observer-blinded study. The patients received alpha-galactosidase (Sinaire Forte, Promefarm, Milan, Italy) 600 GalU t.i.d. for 2 days before abdominal US plus 900 GalU the morning of exam or active charcoal 448 mg t.i.d., for 2 days before the exam plus 672 mg the morning of the exam. Visualization was graded as follows: 0 = none (complete gas interference); 1 = severe interference, 2 = moderate interference, 3 = mild interference; 4 = complete (no gas interference). Results: 42 patients completed the study. Both alpha-galactosidase and active charcoal improved the visualization of target organs. Visualization of the right hepatic lobe, CBD and pancreatic tail was significantly improved (vs. baseline) only by alpha-galactosidase (p < 0.01). Scores ≥3 for all parts of the pancreas and both hepatic lobes were achieved in only 12.5% of the patients after both treatments. Both products were well tolerated. Conclusion: Alpha-galactosidase and active charcoal can improve US visualization of abdominal organs in patients whose scans are frequently unsatisfactory due to excessive intestinal gas. Visualization of the pancreatic tail and right hepatic lobe was significantly improved only by alpha-galactosidase. However, both treatments allowed adequate visualization of all target organs during the same examination only
Ultrasound is a type of imaging. It uses high-frequency sound waves to look at organs and ... liver, and other organs. During pregnancy, doctors use ultrasound to view the fetus. Unlike x-rays, ultrasound ...
Springer, Danielle A.; Allen, Michele; Hoffman, Victoria; Brinster, Lauren; Starost, Matthew F.; Bryant, Mark; Eckhaus, Michael
2014-01-01
Laboratory mice develop naturally occurring lesions that affect biomedical research. Hydronephrosis is a recognized pathologic abnormality of the mouse kidney. Acquired hydronephrosis can affect any mouse, as it is caused by any naturally occurring disease that impairs free urine flow. Many etiologies leading to this condition are of particular significance to aging mice. Non-invasive ultrasound imaging detects renal pelvic dilation, renal enlargement, and parenchymal loss for pre-mortem identification of this condition. High-frequency ultrasound transducers produce high-resolution images of small structures, ideal for detecting organ pathology in mice. Using a 40 MHz linear array transducer, we obtained high-resolution images of a diversity of pathologic lesions occurring within the abdomen of seven geriatric mice with acquired hydronephrosis that enabled a determination of the underlying etiology. Etiologies diagnosed from the imaging results include pyelonephritis, neoplasia, urolithiasis, mouse urologic syndrome, and spontaneous hydronephrosis, and were confirmed at necropsy. A retrospective review of abdominal scans from an additional 149 aging mice shows that the most common etiologies associated with acquired hydronephrosis are mouse urologic syndrome and abdominal neoplasia. This report highlights the utility of high-frequency ultrasound for surveying research mice for age-related pathology, and is the first comprehensive report of multiple cases of acquired hydronephrosis in mice. PMID:25143818
Hunger Games: Interactive Ultrasound Imaging for Learning Gastrointestinal Physiology.
Kafer, Ilana; Rennie, William; Noor, Ali; Pellerito, John S
2017-02-01
Ultrasound is playing an increasingly important role in medical student education. Although most uses of ultrasound have focused on learning purely anatomic relationships or augmentation of the physical examination, there is little documentation of the value of ultrasound as a learning tool regarding physiology alone or in association with anatomy. We devised an interactive learning session for first-year medical students using ultrasound to combine both anatomic and physiologic principles as an integration of gastrointestinal and vascular function. The incorporation of our activity, The Hunger Games, provides the foundation for a powerful integration tool for medical student education. © 2016 by the American Institute of Ultrasound in Medicine.
Sahoo, Jaya Prakash; Kumari, Savita; Jain, Sanjay
2016-04-01
Abdominal obesity is a better marker of adverse metabolic profile than generalized obesity in hypertensive subjects. Further, gender has effect on adiposity and its distribution. Effect of gender on obesity and the distribution of fat in different sub-compartments of abdomen among Indian hypertensive subjects. This observational study included 278 adult subjects (Males-149 & Females-129) with essential hypertension from a tertiary care centre in north India over one year. A detailed history taking and physical examination including anthropometry were performed in all patients. Total Abdominal Fat (TAF) and abdominal adipose tissue sub-compartments like Intra-Abdominal Adipose Tissue (IAAT) and Sub-Cutaneous Adipose Tissue (SCAT) were measured using the predictive equations developed for Asian Indians. Female hypertensive subjects had higher Body Mass Index (BMI) with more overweight (BMI ≥ 23kg/m(2)), and obesity (BMI≥ 25 kg/m(2)). Additionally, they had higher prevalence of central obesity based on both Waist Circumference (WC) criteria (WC≥ 90 cm in males and WC≥ 80 cm in females) and TAF criteria {≥245.6 cm(2) (males) and ≥203.46 cm(2) (females)} than male patients. But there was no difference in the prevalence of central obesity based on Waist Hip Ratio (WHR) criteria (WHR ≥0.90 in males and WHR ≥ 0.85 in females) between two genders. High TAF & IAAT were present in more females although there was no difference in the distribution of high SCAT between two genders. Female hypertensive subjects were more obese with higher abnormal TAF & IAAT compared to male patients. However, there was no difference in the distribution of high SCAT among them.
Amyloidosis - abdominal wall fat pad biopsy; Abdominal wall biopsy; Biopsy - abdominal wall fat pad ... most common method of taking an abdominal wall fat pad biopsy . The health care provider cleans the ...
Ultrasonographic abdominal anatomy of healthy captive caracals (Caracal caracal).
Makungu, Modesta; du Plessis, Wencke M; Barrows, Michelle; Koeppel, Katja N; Groenewald, Hermanus B
2012-09-01
Abdominal ultrasonography was performed in six adult captive caracals (Caracal caracal) to describe the normal abdominal ultrasonographic anatomy. Consistently, the splenic parenchyma was hyperechoic to the liver and kidneys. The relative echogenicity of the right kidney's cortex was inconsistent to the liver. The gall bladder was prominent in five animals and surrounded by a clearly visualized thin, smooth, regular echogenic wall. The wall thickness of the duodenum measured significantly greater compared with that of the jejunum and colon. The duodenum had a significantly thicker mucosal layer compared with that of the stomach. Such knowledge of the normal abdominal ultrasonographic anatomy of individual species is important for accurate diagnosis and interpretation of routine health examinations.
Anterolateral ankle impingement: findings and diagnostic accuracy with ultrasound imaging.
McCarthy, C L; Wilson, D J; Coltman, T P
2008-03-01
The objective was to evaluate the findings and diagnostic accuracy of ultrasound in antero-lateral ankle impingement (ALI) with clinical and arthroscopic correlation. Seventeen elite footballers with chronic ankle pain were referred for ultrasound with a clinical diagnosis of ALI (n = 8) or a control condition (n = 9; lateral mechanical instability, osteochondral defect, intra-articular bodies and osteoarthritis). Ultrasound examination included the antero-lateral gutter for abnormal synovial tissue (synovitic lesion), lateral ligament integrity, tibiotalar joint and osseous spurs of the distal tibia and talus. Ultrasound findings were correlated with subsequent arthroscopic appearance. Ultrasound examination detected a synovitic mass in the antero-lateral gutter in all 8 footballers with clinical ALI (100%) and in 2 patients with a control diagnosis (22%). Arthroscopic correlation of antero-lateral synovitis and fibrosis was present in all 10 cases (100%). The synovitic lesion was seen at ultrasound as a nodular soft tissue mass of mixed echogenicity within the antero-lateral gutter, which extruded anteriorly with manual compression of the distal fibula against the tibia. Increased blood supply was detected using power Doppler imaging in only 1 patient. The synovitic lesion measured >10 mm in its maximum dimension in 7 footballers with clinical ALI and <10 mm in the control group. Additional ultrasound findings in patients with abnormal antero-lateral synovial tissue included an anterior talofibular ligament injury in all patients (n = 10), a tibiotalar joint effusion (n = 6) and osseous spurs (n = 4). Antero-lateral synovitic tissue was accurately identified at ultrasound in the absence of an effusion (n = 4). No synovitic lesion was detected at ultrasound or arthroscopy in the remaining 7 patients with a control diagnosis. Ultrasound is accurate in detecting synovitic lesions within the antero-lateral gutter, demonstrating associated ligamentous injuries and in
[Is the stomach a main landmark on the abdominal circumference? Audit of 3 operators].
Laurent, A-C; Blanc, J; Grangé, G
2016-05-01
The fetal weight estimation depends largely on the accuracy of abdominal circumference. The quality criteria are standardized to minimize variability and include visualization of the stomach. The objective of this study is to investigate the presence or absence of the stomach on the abdominal circumference for 3 different operators. We conducted re-reading of 204 ultrasound images in the second and third trimester of pregnancy, performed by three operators, at the maternity Port Royal in Paris in 2013. On these images, the presence of the stomach was sought and other quality criteria were verified. Among the 204 images, 166 included the stomach (81%). When studying for each of the three operators, there were 79%, 72% and 98% of the stomach into the abdominal circumference, a significant difference between operators (P=0.0029). Regarding the secondary criteria, the quality criteria found most often were the calipers and well placed ellipse (89%). According to the previous studies, the stomach seems to be a reference to search. Our study shows variability depending on the different operators. If a hierarchy of quality criteria is to be considered, the stomach does not seem to be the first criterion to search. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Wu, Chun-Yu; Lin, Feng-Sheng; Wang, Yi-Chia; Chou, Wei-Han; Lin, Wen-Ying; Sun, Wei-Zen; Lin, Chih-Peng
2015-01-01
The role of ultrasound examination in detection of postprocedure complications from totally implantable venous access devices (TIVAD) placement is still uncertain. In a cohort of 665 cancer outpatients, we assessed a quick ultrasound examination protocol in early detection of mechanical complications of catheterization. Immediately after TIVAD placement, an ultrasound examination and chest radiography were performed to detect hemothorax, pneumothorax, and catheter malposition. The two methods were compared. Of the 668 catheters inserted, 628 were placed into axillary veins and 40 into internal jugular veins. The ultrasound examination took 2.5 ± 1.1 min. No hemothorax was detected, and neither pneumothorax nor catheter malposition was evident among the 40 internal jugular vein cannulations. Ultrasound and chest radiography examinations of the 628 axillary vein cannulations detected five and four instances of pneumothorax, respectively. Ultrasound detected all six catheter malpositions into the internal jugular vein. However, ultrasound failed to detect two out of three malpositions in the contralateral brachiocephalic vein and one kinking inside the superior vena cava. Without revision surgery, the operating time was 34.1 ± 15.6 min. With revision surgery, the operating time was shorter when ultrasound detected catheter malposition than when chest radiography was used (96.8 ± 12.9 vs. 188.8 ± 10.3 min, p < 0.001). Postprocedure ultrasound examination is a quick and sensitive method to detect TIVAD-related pneumothorax. It also precisely detects catheter malposition to internal jugular vein thus reduces time needed for revision surgery while chest radiography remains necessary to confirm catheter final position.
MedlinePlus Videos and Cool Tools
Ultrasound is a useful procedure for monitoring the baby's development in the uterus. Ultrasound uses inaudible sound waves to produce a two- ... sound waves and appear dark or black. An ultrasound can supply vital information about a mother's pregnancy ...
Morelli, Girolamo; Pagni, Riccardo; Mariani, Chiara; Minervini, Riccardo; Morelli, Andrea; Gori, Francesco; Ferdeghini, Ezio Maria; Paterni, Marco; Mauro, Eva; Guidi, Elisa; Armillotta, Nicola; Canale, Domenico; Vitti, Paolo; Caramella, Davide; Minervini, Andrea
2011-06-01
We evaluated the ability of the phosphodiesterase-5 inhibitor vardenafil to increase prostate microcirculation during power Doppler ultrasound. We also evaluated the results of contrast and vardenafil enhanced targeted biopsies compared to those of standard 12-core random biopsies to detect cancer. Between May 2008 and January 2010, 150 consecutive patients with prostate specific antigen more than 4 ng/ml at first diagnosis with negative digital rectal examination and transrectal ultrasound, and no clinical history of prostatitis underwent contrast enhanced power Doppler ultrasound (bolus injection of 2.4 ml SonoVue® contrast agent), followed by vardenafil enhanced power Doppler ultrasound (1 hour after oral administration of vardenafil 20 mg). All patients underwent standard 12-core transrectal ultrasound guided random prostate biopsy plus 1 further sampling from each suspected hypervascular lesion detected by contrast and vardenafil enhanced power Doppler ultrasound. Prostate cancer was detected in 44 patients (29.3%). Contrast and vardenafil enhanced power Doppler ultrasound detected suspicious, contrast enhanced and vardenafil enhanced areas in 112 (74.6%) and 110 patients (73.3%), and was diagnostic for cancer in 32 (28.5%) and 42 (38%), respectively. Analysis of standard technique, and contrast and vardenafil enhanced power Doppler ultrasound findings by biopsy core showed significantly higher detection using vardenafil vs contrast enhanced power Doppler ultrasound and standard technique (41.2% vs 22.7% and 8.1%, p <0.005 and <0.001, respectively). The detection rate of standard plus contrast or vardenafil enhanced power Doppler ultrasound was 10% and 11.7% (p not significant). Vardenafil enhanced power Doppler ultrasound enables excellent visualization of the microvasculature associated with cancer and can improve the detection rate compared to contrast enhanced power Doppler ultrasound and the random technique. Copyright © 2011 American Urological
Update on the prevention of death from ruptured abdominal aortic aneurysm.
Jacomelli, Jo; Summers, Lisa; Stevenson, Anne; Lees, Tim; Earnshaw, Jonothan J
2017-09-01
Objectives To monitor the early effect of a national population screening programme for abdominal aortic aneurysm in 65-year-old men. Setting The study used national statistics for death rates from abdominal aortic aneurysm (Office of National Statistics) and hospital admission data in England (Hospital Episode Statistics). Methods Information concerning deaths from abdominal aortic aneurysm (ruptured and non-ruptured) (1999-2014) and hospital admissions for ruptured abdominal aortic aneurysm (2000-2015) was examined. Results The absolute number of deaths from abdominal aortic aneurysm in men and women aged 65 and over has decreased by around 30% from 2001 to 2014, but as the population has increased, the relative reduction was 45.6% and 40.0%, respectively. Some 65% of all abdominal aortic aneurysm deaths are in men aged over 65; women aged 65 and over account for around 31%. Deaths from ruptured abdominal aortic aneurysm in men aged 60-74 (the screened group) appear to be declining at the same rate as in men aged 75 and over. The relative decline in admissions to hospital with ruptured abdominal aortic aneurysm may be greater in men and women aged 60-74 (which contains the screened group of men), than those older, giving the first possible evidence that abdominal aortic aneurysm screening is having an effect. Conclusion The death rate from abdominal aortic aneurysm is declining rapidly in England. There is the first evidence that screening may be contributing to this reduction.
Diode laser for abdominal tissue cauterization
NASA Astrophysics Data System (ADS)
Durville, Frederic M.; Rediker, Robert H.; Connolly, Raymond J.; Schwaitzberg, Steven D.; Lantis, John
1999-06-01
We have developed a new device to effectively and quickly stop bleeding. The new device uses a small, 5 W diode laser to heat-up the tip of a modified medical forceps. The laser beam is totally contained within a protective enclosure, satisfying the requirements for a Class I laser system, which eliminates the need to protective eyewear. The new device is used in a manner similar to that of a bipolar electrocautery device. After visual location, the bleeding site or local vessel(s) is grabbed and clamped with the tips of the forceps-like instrument. The laser is then activated for a duration of typically 5 sec or until traditional visual or auditory clues such as local blubbling and popping indicate that the targeted site is effectively cauterized. When the laser is activated, the tip of the instrument, thus providing hemostasis. The new device was evaluated in animal models and compared with the monopolar and bipolar electrocautery, and also with the recently developed ultrasound technology. It has new been in clinical trials for abdominal surgery since September 1997.
[Diagnostic ultrasound in pneumothorax].
Maury, É; Pichereau, C; Bourcier, S; Galbois, A; Lejour, G; Baudel, J-L; Ait-Oufella, H; Guidet, B
2016-10-01
For a long time the lung has been regarded as inaccessible to ultrasound. However, recent clinical studies have shown that this organ can be examined by this technique, which appears, in some situations, to be superior to thoracic radiography. The examination does not require special equipment and is possible using a combination of simple qualitative signs: lung sliding, the presence of B lines and the demonstration of the lung point. The lung sliding corresponds to the artefact produced by the movement of the two pleural layers, one against the other. The B lines indicate the presence of an interstitial syndrome. The presence of lung sliding and/or B lines has a negative predictive value of 100% and formally excludes a pneumothorax in the area where the probe has been applied. The presence of the lung point is pathognomonic of pneumothorax but the sensitivity is no more than 60%. Ultrasound is therefore a rapid and simple means of excluding a pneumothorax (lung sliding or B lines) and of confirming a pneumothorax when the lung point is visible. The question that remains is whether ultrasound can totally replace radiography in the management of this disorder. Copyright © 2015 SPLF. Published by Elsevier Masson SAS. All rights reserved.
Development of a robust MRI fiducial system for automated fusion of MR-US abdominal images.
Favazza, Christopher P; Gorny, Krzysztof R; Callstrom, Matthew R; Kurup, Anil N; Washburn, Michael; Trester, Pamela S; Fowler, Charles L; Hangiandreou, Nicholas J
2018-05-21
We present the development of a two-component magnetic resonance (MR) fiducial system, that is, a fiducial marker device combined with an auto-segmentation algorithm, designed to be paired with existing ultrasound probe tracking and image fusion technology to automatically fuse MR and ultrasound (US) images. The fiducial device consisted of four ~6.4 mL cylindrical wells filled with 1 g/L copper sulfate solution. The algorithm was designed to automatically segment the device in clinical abdominal MR images. The algorithm's detection rate and repeatability were investigated through a phantom study and in human volunteers. The detection rate was 100% in all phantom and human images. The center-of-mass of the fiducial device was robustly identified with maximum variations of 2.9 mm in position and 0.9° in angular orientation. In volunteer images, average differences between algorithm-measured inter-marker spacings and actual separation distances were 0.53 ± 0.36 mm. "Proof-of-concept" automatic MR-US fusions were conducted with sets of images from both a phantom and volunteer using a commercial prototype system, which was built based on the above findings. Image fusion accuracy was measured to be within 5 mm for breath-hold scanning. These results demonstrate the capability of this approach to automatically fuse US and MR images acquired across a wide range of clinical abdominal pulse sequences. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.