Sample records for abnormal umbilical artery

  1. [Assessment of blood flow in the middle cerebral artery and the umbilical artery in fetuses with umbilical venous pulsations].

    PubMed

    Borowski, Dariusz; Czuba, Bartosz; Kaczmarek, Piotr; Włoch, Agata; Pawłowicz, Paweł; Wyrwas, Dorota; Wielgos, Mirosław; Sodowski, Krzysztof; Szaflik, Krzysztof

    2006-03-01

    Umbilical venous pulsation is an important sign of hemodynamic compromise, especially during fetal heart failure and asphyxia. The aim of this study was to determine of the blow flow in the middle cerebral artery and the umbilical artery in fetuses with umbilical venous pulsations. The investigation included 18 fetuses with signs of the intrauterine growth restriction and umbilical venous pulsations after 28th weeks of gestation. We evaluated cerebral-placental ratio (CPR) and pulsation index (PI) in the middle cerebral artery (MCA) and the umbilical artery (UA). We observed brain sparring effect in all cases of analyzing fetuses. There were 77,8% of abnormal flow pattern in umbilical artery. 13 fetuses had a single pulsation pattern in umbilical vein and another 5 had double pulsation pattern. The coexistence of umbilical vein pulsation and abnormal flow pattern in umbilical artery is closely related to increased perinatal mortality.

  2. Placental disease and abnormal umbilical artery Doppler waveforms in trisomy 21 pregnancy: A case-control study.

    PubMed

    Corry, Edward; Mone, Fionnuala; Segurado, Ricardo; Downey, Paul; McParland, Peter; McAuliffe, Fionnuala M; Mooney, Eoghan E

    2016-11-01

    The objectives of this study were firstly to determine the proportion of placental pathology in fetuses affected by trisomy 21 (T21) using current pathological descriptive terminology and secondly to examine if a correlation existed between the finding of an abnormal umbilical artery Doppler (UAD) waveform, the presence of T21 and defined placental pathological categories. This case-control study assessed singleton fetuses with karyotypically confirmed trisomy 21 where placental histopathology had been conducted from 2003 to 2015 inclusive, within a university tertiary obstetric centre. This was compared with unselected normal singleton control pregnancies matched within a week of gestation at delivery. Data included birthweight centiles and placental histopathology. Comparisons of Doppler findings across placental pathological categories were performed using statistical analysis. 104 cases were analysed; 52 cases of trisomy 21 and 52 controls. Fetal vascular malperfusion (48.1% vs. 5.8%, p = 0.001) and maturation defects (39.2% vs. 15.7%, p = 0.023) were more common in trisomy 21 placentas. Compared with controls, trisomy 21 fetuses were more likely to have shorter umbilical cords (p = 0.001) and had more UAD abnormalities. Amongst T21 pregnancies, umbilical artery Doppler abnormalities are associated with the presence of maternal vascular malperfusion. Fetal vascular malperfusion and maturation defects are more common in trisomy 21 placentas. Abnormal umbilical artery Doppler waveforms are more common in T21 and are associated with maternal vascular malperfusion. Placental disease may explain the increased rate of intrauterine death in T21. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Evaluation of feline uterine and umbilical arteries blood flow in a pharmacologically induced abnormal gestation model.

    PubMed

    Blanco, P G; Vercellini, R; Rube, A; Rodríguez, R; Arias, D O; Gobello, C

    2016-12-01

    The aim of this study was to describe resistance index (RI) and systolic/diastolic ratio (S/D ratio) of uterine and umbilical arteries in an experimental model of abnormal pregnancy in felids. On days 30 to 35 (32 ± 2.9) after mating, 20 domestic short-hair pregnant queens were randomly assigned to one of the following treatment groups: a treated group (TG; n = 8), which received 10 mg/kg of aglepristone subcutaneously twice, 24 hours apart, and a control nontreated group (CG; n = 12). M-mode and Doppler ultrasonographic evaluations were performed at the initiation of the treatment (Day 0) and then every other day during 8 days. In both groups, uterine and umbilical arteries were evaluated by Doppler ultrasound, whereas fetal heart rate was assessed by M-mode ultrasound. Resistance index of uterine artery augmented in TG from Day 2 onward, conversely it decreased in CG (P < 0.01). On Day 8, RI values were 0.64 ± 0.05 vs 0.37 ± 0.01 for TG and CG, respectively. Additionally, S/D ratio of the same artery presented an increase in TG, whereas this ratio diminished in CG (P < 0.01). On Day 8, this parameter showed values of 2.98 ± 0.4 vs 1.62 ± 0.06 for TG and CG, respectively. Resistance index of umbilical artery remained almost unchanged in TG from Day 6 onward, whereas it progressively decreased in CG throughout the course of the study (P < 0.05). On Day 8, RI were 0.89 ± 0.04 and 0.82 ± 0.01, for TG and CG, respectively. Furthermore, on Day 8, S/D ratio of umbilical artery progressively diminished in CG but not in TG (P < 0.01), being 14.7 ± 9.1 vs 5.9 ± 0.3 for TG and CG, respectively. Fetal heart rate was higher in TG than in CG (P < 0.05). Group differences in Doppler parameters appeared on Day 2, when the other clinical or ultrasonographic signs were still absent. It is concluded that blood flow of the uterine and umbilical arteries differed between these normal and abnormal gestations predicting an adverse obstetric

  4. Abnormal umbilical cord Dopplers may predict impending demise in fetuses with sacrococcygeal teratoma. A report of 2 cases.

    PubMed

    Olutoye, Oluyinka O; Johnson, Mark P; Coleman, Beverly G; Crombleholme, Timothy M; Adzick, N Scott; Flake, Alan W

    2003-01-01

    To identify factors predictive of fetal demise in fetuses with sacrococcygeal teratoma (SCT). The recent management of monochorionic twins discordant for a large SCT and a singleton with a large SCT were reviewed. Serial fetal echocardiography and ultrasonography with Doppler flow measurements documented rapid growth of the SCT in both cases with a relatively modest increase in combined cardiac output. No placentomegaly or hydrops was observed at any time. In both fetuses with SCT, evolution of abnormal umbilical artery waveforms was observed with the ultimate development of reversed end-diastolic umbilical arterial flow that was followed by sudden fetal demise. Death in these 2 fetuses with large SCTs in the absence of placentomegaly/hydrops or hemodynamic changes suggestive of evolving high-output failure suggests a previously unrecognized mechanism of death in fetuses with large rapidly growing SCTs. In these cases, fetal demise may only be heralded by abnormal umbilical artery waveforms that progress to the premorbid observation of reversed diastolic umbilical artery blood flow. Umbilical artery waveform analysis should be closely monitored with other hemodynamic parameters in fetuses with large SCTs. In such fetuses, depending on the gestational age, abnormalities in umbilical artery waveform should be considered indications for early delivery or in utero intervention to prevent fetal demise. Copyright 2003 S. Karger AG, Basel

  5. Abnormal umbilical cord Doppler sonograms may predict impending demise in fetuses with sacrococcygeal teratoma. A report of two cases.

    PubMed

    Olutoye, Oluyinka O; Johnson, Mark P; Coleman, Beverly G; Crombleholme, Timothy M; Adzick, N Scott; Flake, Alan W

    2004-01-01

    To identify factors predictive of fetal demise in fetuses with sacrococcygeal teratoma (SCT). The recent management of monochorionic twins discordant for a large SCT and a singleton with a large SCT was reviewed. Serial fetal echocardiography and ultrasonography with Doppler flow measurements documented rapid growth of the SCT in both cases with a relatively modest increase in combined cardiac output. No placentomegaly or hydrops was observed at any time. In both fetuses with SCT, evolution of abnormal umbilical artery waveforms was observed with the ultimate development of reversed end-diastolic umbilical arterial flow that was followed by sudden fetal demise. Death in these 2 fetuses with large SCTs in the absence of placentomegaly/hydrops or hemodynamic changes suggestive of evolving high-output failure suggests a previously unrecognized mechanism of death in fetuses with large rapidly growing SCTs. In these cases, fetal demise may only be heralded by abnormal umbilical artery waveforms that progress to the premorbid observation of reversed diastolic umbilical artery blood flow. Umbilical artery waveform analysis should be closely monitored with other hemodynamic parameters in fetuses with large SCTs. In such fetuses, depending on the gestational age, abnormalities in umbilical artery waveform should be considered indications for early delivery or in utero intervention to prevent fetal demise. Copyright 2004 S. Karger AG, Basel

  6. Sonographic diagnosis and clinical significance of umbilical arterial atresia.

    PubMed

    Ren, Jinhe

    2017-05-01

    To evaluate the feasibility of antenatal sonographic diagnosis of umbilical arterial atresia and its clinical significance. Data of 5 cases with umbilical arterial atresia diagnosed in our hospital were studied retrospectively. The antenatal ultrasonogram of umbilical arterial atresia was obtain, and the pathological examination of umbilical cords and the prognosis of neonates were analyzed. Among 5 cases with umbilical arterial atresia in this group, 1 case with double umbilical arterial atresia was found with dead fetus in uterus, and the rest 4 cases with single umbilical arterial atresia were found with survival fetuses. In the latter 4 cases with live fetus, once umbilical arterial atresia was diagnosed, cesarean section was performed to terminate pregnancy, and the 4 fetus were all healthy. The chromosome karyotypes and S/D value of umbilical arteries were showed normal in all 5 cases. Accurate antenatal diagnosis can be made according to the specific ultrasonogram of umbilical arterial atresia. Instant intervention should be performed upon observing umbilical arterial atresia with live fetus, so as to avoid dead fetus as much as possible.

  7. Neonatal nucleated red blood cell counts in small-for-gestational age fetuses with abnormal umbilical artery Doppler studies.

    PubMed

    Bernstein, P S; Minior, V K; Divon, M Y

    1997-11-01

    The presence of elevated nucleated red blood cell counts in neonatal blood has been associated with fetal hypoxia. We sought to determine whether small-for-gestational-age fetuses with abnormal umbilical artery Doppler velocity waveforms have elevated nucleated red blood cell counts. Hospital charts of neonates with the discharge diagnosis of small for gestational age (birth weight < 10th percentile) who were delivered between October 1988 and June 1995 were reviewed for antepartum testing, delivery conditions, and neonatal outcome. We studied fetuses who had an umbilical artery systolic/diastolic ratio within 3 days of delivery and a complete blood cell count on the first day of life. Multiple gestations, anomalous fetuses, and infants of diabetic mothers were excluded. Statistical analysis included the Student t test, chi 2 analysis, analysis of variance, and simple and stepwise regression. Fifty-two infants met the inclusion criteria. Those with absent or reversed end-diastolic velocity (n = 19) had significantly greater nucleated red blood cell counts than did those with end-diastolic velocity present (n = 33) (nucleated red blood cells/100 nucleated cells +/- SD: 135.5 +/- 138 vs 17.4 +/- 23.7, p < 0.0001). These infants exhibited significantly longer time intervals for clearance of nucleated red blood cells from their circulation (p < 0.0001). They also had lower birth weights (p < 0.05), lower initial platelet count (p = 0.0006), lower arterial cord blood pH (p < 0.05), higher cord blood base deficit (p < 0.05), and an increased likelihood of cesarean section for "fetal distress" (p < 0.05). Multivariate analysis demonstrated that absent or reversed end-diastolic velocity (p < 0.0001) and low birth weight (p < 0.0001) contributed to the elevation of the nucleated red blood cell count, whereas gestational age at delivery was not a significant contributor. We observed significantly greater nucleated red blood cell counts and lower platelet counts in small

  8. Abnormal arterial flows by a distributed model of the fetal circulation.

    PubMed

    van den Wijngaard, Jeroen P H M; Westerhof, Berend E; Faber, Dirk J; Ramsay, Margaret M; Westerhof, Nico; van Gemert, Martin J C

    2006-11-01

    Modeling the propagation of blood pressure and flow along the fetoplacental arterial tree may improve interpretation of abnormal flow velocity waveforms in fetuses. The current models, however, either do not include a wide range of gestational ages or do not account for variation in anatomical, vascular, or rheological parameters. We developed a mathematical model of the pulsating fetoumbilical arterial circulation using Womersley's oscillatory flow theory and viscoelastic arterial wall properties. Arterial flow waves are calculated at different arterial locations from which the pulsatility index (PI) can be determined. We varied blood viscosity, placental and brain resistances, placental compliance, heart rate, stiffness of the arterial wall, and length of the umbilical arteries. The PI increases in the umbilical artery and decreases in the cerebral arteries, as a result of increasing placental resistance or decreasing brain resistance. Both changes in resistance decrease the flow through the placenta. An increased arterial stiffness increases the PIs in the entire fetoplacental circulation. Blood viscosity and peripheral bed compliance have limited influence on the flow profiles. Bradycardia and tachycardia increase and decrease the PI in all arteries, respectively. Umbilical arterial length has limited influence on the PI but affects the mean arterial pressure at the placental cord insertion. The model may improve the interpretation of arterial flow pulsations and thus may advance both the understanding of pathophysiological processes and clinical management.

  9. Type II single umbilical artery (persistent vitelline artery) in an otherwise normal fetus.

    PubMed

    Gamzu, Ronni; Zalel, Yaron; Jacobson, Jeffrey M; Screiber, Leticia; Achiron, Reuven

    2002-11-01

    A single umbilical artery resulting from absence of the umbilical arteries and persistence of the vitelline artery that arises directly from the abdominal aorta has been described only in malformed fetuses with sirenomelia or caudal regression. Such an aberrant artery was suggested to be the etiology of sirenomelia caused by a 'steal' mechanism of blood flow from the caudal end of the embryo. We present a case in which prenatal ultrasound showed a similar aberrant single artery arising from the abdominal aorta in an otherwise normal fetus with a normal course of pregnancy. This vessel, a continuation of the superior mesenteric artery (SMA), corresponds to a persistent vitelline artery assuming the function of the umbilical arteries. The etiology of such a finding and its possible consequences are discussed. Copyright 2002 John Wiley & Sons, Ltd.

  10. Neonatal oxidative stress depends on oxygen blood pressure in umbilical artery.

    PubMed

    Proietti, F; De Bernardo, G; Longini, M; Sordino, D; Scaramuzzini, G; Tataranno, M L; Belvisi, E; Bazzini, F; Perrone, S; Buonocore, G

    2016-01-01

    With advancing gestation, partial pressure of oxygen (pO2) and pH fall significantly. Hypoxia is a main factor inducing free radical generation and thereby oxidative stress (OS). Placental and fetal tissue response when oxygen becomes restricted is complex and partially known. We tested the hypothesis that changes in umbilical artery and vein blood gas concentrations modulate OS occurrence in the newborn. Seventy umbilical artery and vein plasma samples were collected from healthy term newborns immediately after delivery. F2 Isoprostanes (F2-Isop) were measured in all samples as reliable markers of lipid peroxidation. Significantly lower pCO2 and higher pO2 and pH were found in umbilical vein than in artery, as expected. A positive correlation was detected between pH and pO2 only in umbilical artery (p=0.019). F2-Isop levels were no different between artery and vein in cord blood. Significant correlations were found between F2-Isop and pCO2 (p=0.025) as well as between F2-Isop and pH in umbilical vein (p=0.027). F2-Isop correlated with pCO2 (p=0.007) as well as with pO2 values (p=0.005) in umbilical artery blood. Oxidative stress (OS) in newborns depends on oxygen concentrations in umbilical artery. OS biomarkers significantly correlate with pO2 and in umbilical artery but not in umbilical vein. In normoxic conditions fetal-maternal gas exchanges occurring in placenta re-establish normal higher oxygen levels in umbilical vein than artery, with a normal production of free radicals without any deleterious effects.

  11. Obstructed Umbilical Hernia: A Normal Presentation with Abnormal Contents.

    PubMed

    P Agrawal, Vijay; S Shetty, Nikhil; Narasimhaprasad, Ashwin

    2015-01-01

    Umbilical hernia is a common problem encountered in children. The rarity of finding cecum and appendix is probably due to the fact that the appendix is seldom found in the proximity of the umbilicus. It would, therefore, appear worthwhile to report the occurrence of cecum and an inflamed appendix with Ladd's bands in an umbilical hernia of a child. The last case with similar presentation was presented in 1950s. Agrawal VP, Shetty NS, Narasimhaprasad A. Obstructed Umbilical Hernia: A Normal Presentation with Abnormal Contents. Euroasian J Hepato-Gastroenterol 2015;5(2):110-111.

  12. Ultrasonography of umbilical structures in clinically normal foals.

    PubMed

    Reef, V B; Collatos, C

    1988-12-01

    The umbilical arteries, urachus, and umbilical vein were scanned ultrasonographically in 13 clinically normal foals that ranged in age from 6 hours to 4 weeks. Sonograms were obtained using a 7.5-MHz sector scanner transducer placed across the midline of the ventral portion of the foal's abdominal wall. The umbilical vein was scanned from the umbilical stalk to its entrance into the hepatic parenchyma. The mean (+/- SD) diameter of the umbilical vein was 0.61 +/- 0.20 cm immediately cranial to the umbilical stalk, 0.52 +/- 0.19 cm midway between the umbilicus and liver, and 0.6 +/- 0.19 cm at the liver. The urachus and umbilical arteries were scanned from the umbilical stalk to the apex of the urinary bladder and had a mean total diameter of 1.75 +/- 0.37 cm at the bladder apex. The umbilical arteries also were scanned along either side of the bladder and had a mean diameter of 0.85 +/- 0.21 cm. These measurements and the ultrasonographic appearance of the internal umbilical structures from clinically normal foals can be used as references to diagnose abnormalities of the umbilical structures in neonatal foals.

  13. Obstructed Umbilical Hernia: A Normal Presentation with Abnormal Contents

    PubMed Central

    P Agrawal, Vijay; Narasimhaprasad, Ashwin

    2015-01-01

    Umbilical hernia is a common problem encountered in children. The rarity of finding cecum and appendix is probably due to the fact that the appendix is seldom found in the proximity of the umbilicus. It would, therefore, appear worthwhile to report the occurrence of cecum and an inflamed appendix with Ladd’s bands in an umbilical hernia of a child. The last case with similar presentation was presented in 1950s. How to cite this article Agrawal VP, Shetty NS, Narasimhaprasad A. Obstructed Umbilical Hernia: A Normal Presentation with Abnormal Contents. Euroasian J Hepato-Gastroenterol 2015;5(2):110-111. PMID:29201704

  14. [Persistent neonatal hypoglycaemia caused by arterial positioning of the umbilical venous catheter].

    PubMed

    Peters, P A G; Brus, F; Noordam, C; Smorenburg, M K; van Setten, P A

    2007-10-06

    Two neonates, a girl born at 40 2/7 weeks weighing 4165 g and a boy born at 37 6/7 weeks weighing 4040 g, received umbilical venous catheters to help manage hypoglycaemia. The catheter was ineffective or only effective when high doses of glucose were used, due to what later appeared to be arterial positioning of the catheter. Both patients recovered without consequences. Persistent hypoglycaemia is a common problem in newborns and can cause severe neurological sequelae. A relatively uncommon cause is malpositioning of the umbilical catheter. Positioning in an artery leads to direct infusion of glucose into the pancreas, which causes hyperinsulinaemia and can lead to potentially dangerous nonketotic hypoglycaemia. Arterial positioning of the umbilical catheter should be ruled out at an early stage. Correct catheter positioning can be determined using careful inspection of the umbilical veins, radiological examination of the catheter position, blood gas analysis or vascular pulsation.

  15. Umbilical artery histomorphometry: a link between the intrauterine environment and kidney development.

    PubMed

    DeFreitas, M J; Mathur, D; Seeherunvong, W; Cano, T; Katsoufis, C P; Duara, S; Yasin, S; Zilleruelo, G; Rodriguez, M M; Abitbol, C L

    2017-06-01

    Prematurity is a risk factor for hypertension, vascular stiffness, nephron deficit and adult onset cardiorenal disease. The vascular tree and kidneys share morphogenic drivers that promote maturation in utero before 36 weeks of gestation. Vascular elastin accrual terminates after birth leaving collagen to promote vascular stiffness. Our objective was to determine if the histomorphometry of the umbilical artery, an extension of the aorta, parallels nephron mass across gestational age groups. From a cohort of 54 newborns, 32 umbilical cord specimens were adequate for evaluation. The umbilical cord was sectioned, stained with trichrome, and digitalized. Muscular and collagenous areas of the umbilical artery were measured in pixels using the Image J 1.48q software. Total kidney volume was measured by ultrasound and factored by body surface area (TKV/BSA). The umbilical artery total area was significantly greater in term v. preterm infants (9.3±1.3 v. 7.0±2.0 mm2; P<0.05) and increased with gestational age; while the percent muscular and collagen areas were independent of gestational age (R 2=0.04; P=ns). Percent muscular area correlated positively with TKV/BSA (r=0.53; P=0.002); while an increase in collagen correlated inversely with kidney mass (r=-0.53; P=0.002). In conclusion, an enhanced % muscular area and presumed vascular elasticity was associated with increased renal mass in all infants. Umbilical artery histomorphometry provides a link between the intrauterine environment, vascular and kidney development.

  16. Assessment of umbilical artery flow and fetal heart rate to predict delivery time in bitches.

    PubMed

    Giannico, Amália Turner; Garcia, Daniela Aparecida Ayres; Gil, Elaine Mayumi Ueno; Sousa, Marlos Gonçalves; Froes, Tilde Rodrigues

    2016-10-15

    The aim of this study was to quantitatively investigate the oscillation of the fetal heart rate (HR) in advance of normal delivery and whether this index could be used to indicate impending delivery. In addition, fetal HR oscillation and umbilical artery resistive index (RI) were correlated to determine if the combination of these parameters provided a more accurate prediction of the time of delivery. Sonographic evaluation was performed in 11 pregnant bitches to evaluate the fetal HR and umbilical artery RI at the following antepartum times: 120 to 96 hours, 72 to 48 hours, 24 to 12 hours, and 12 to 1 hours. Statistical analysis indicated a correlation between the oscillation of fetal HR and the umbilical artery RI. As delivery approached a considerable reduction in the umbilical artery RI was documented and greater oscillations between maximum and minimum HRs occurred. We conclude that the quantitative analysis of fetal HR oscillations may be used to predict the time of delivery in bitches. The combination of fetal HR and umbilical artery RI together may provide more accurate predictions of time of delivery. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Effect of body position and ventilation on umbilical artery and venous blood flows during delayed umbilical cord clamping in preterm lambs.

    PubMed

    Hooper, Stuart B; Crossley, Kelly J; Zahra, Valerie A; van Vonderen, Jeroen; Moxham, Alison; Gill, Andrew W; Kluckow, Martin; Te Pas, Arjan B; Wallace, Euan M; Polglase, Graeme R

    2017-07-01

    While delayed umbilical cord clamping (UCC) is thought to facilitate placental to infant blood transfusion, the physiological factors regulating flow in the umbilical arteries and veins during delayed UCC is unknown. We investigated the effects of gravity, by changing fetal height relative to the placenta, and ventilation on umbilical blood flows and the cardiovascular transition during delayed UCC at birth. Catheters and flow probes were implanted into preterm lambs (128 days) prior to delivery to measure pulmonary, carotid, umbilical artery (UaBF) and umbilical venous (UvBF) blood flows. Lambs were placed either 10 cm below or 10 cm above the ewe. Ventilation commenced 2-3 min before UCC and continued for 30 min after UCC. Gravity reduced umbilical and cerebral flows when lambs were placed below the midline, but the reduction in UaBF and UvBF was similar. Ventilation during delayed UCC reduced UvBF and UaBF by similar amounts, irrespective of the lamb's position, such that flows into and out of the placenta remained balanced. The effects of ventilation on umbilical flows were much greater than the effects of gravity, but no net placental to lamb blood transfusion could be detected under any condition. Cardiovascular parameters, cerebral oxygen kinetics and final blood volumes were similar in both groups 5 min after UCC. Gravity caused small transient effects on umbilical and cerebral flow, but given changes were similar in umbilical arteries and veins, no net placental transfusion was detected. Ventilation during delayed UCC has a markedly greater influence on cardiovascular function in the newborn. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  18. Hypoxic ischemic encephalopathy in newborns linked to placental and umbilical cord abnormalities.

    PubMed

    Nasiell, Josefine; Papadogiannakis, Nikos; Löf, Erika; Elofsson, Fanny; Hallberg, Boubou

    2016-03-01

    Birth asphyxia and hypoxic ischemic encephalopathy (HIE) of the newborn remain serious complications. We present a study investigating if placental or umbilical cord abnormalities in newborns at term are associated with HIE. A prospective cohort study of the placenta and umbilical cord of infants treated with hypothermia (HT) due to hypoxic brain injury and follow-up at 12 months of age has been carried out. The study population included 41 infants treated for HT whose placentas were submitted for histopathological analysis. Main outcome measures were infant development at 12 months, classified as normal, cerebral palsy, or death. A healthy group of 100 infants without HIE and normal follow-up at 12 months of age were used as controls. A velamentous or marginal umbilical cord insertion and histological abruption was associated with the risk of severe HIE, OR = 5.63, p = 0.006, respectively, OR = 20.3, p = 0.01 (multiple-logistic regression). Velamentous or marginal umbilical cord insertion was found in 39% among HIE cases compared to 7% in controls. Placental and umbilical cord abnormalities have a profound association with HIE. A prompt examination of the placentas of newborns suffering from asphyxia can provide important information on the pathogenesis behind the incident and contribute to make a better early prognosis.

  19. Anatomical description of the umbilical arteries and impact of their ligation on pelvic and perineal vascular supply after cystectomy in women.

    PubMed

    Chantalat, E; Vaysse, C; Delchier, M C; Bordier, B; Game, X; Chaynes, P; Cavaignac, E; Roumiguié, M

    2018-03-27

    In radical cystectomy, the surgeon generally ligates the umbilical artery at its origin. This artery may give rise to several arteries that supply the sexual organs. Our aim was to evaluate pelvic and perineal devascularisation in women after total cystectomy. We carried out a prospective anatomical and radiological study. We performed bilateral pelvic dissections of fresh adult female cadavers to identify the dividing branches of the umbilical artery. In parallel, we examined and compared the pre- and postoperative imaging investigations [magnetic resonance imaging (MRI) angiography] in patients undergoing cystectomy for benign disease to quantify the loss of pelvic vascularisation on the postoperative images by identifying the occluded arteries. The anatomical study together with the radiological study visualised 35 umbilical arteries (n = 70) with their branching patterns and collateral arteries. The uterine artery originated from the umbilical artery in more than 75% of cases (n = 54) of the internal pudendal artery in 34% (n = 24) and the vaginal artery in 43% (n = 30). The postoperative MRI angiograms showed pelvic devascularisation in four patients. Devascularisation was dependent on the level of surgical ligation. In the four patients with loss of pelvic vascular supply, the umbilical artery had been ligated at its origin. The umbilical artery gives rise to various branches that supply the pelvis and perineum. If the surgeon ligates the umbilical artery at its origin during total cystectomy, there is a significant risk of pelvic and perineal devascularisation.

  20. Absent end diastolic flow of umbilical artery Doppler: pregnancy outcome in 62 cases.

    PubMed

    Poulain, P; Palaric, J C; Milon, J; Betremieux, P; Proudhon, J F; Signorelli, D; Grall, J Y; Giraud, J R

    1994-02-01

    We retrospectively studied the outcome of pregnancy in 62 cases of absent end diastolic flow (AEDF) of umbilical artery Doppler flow velocity waveform. The history of pregnancies revealed that nearly all were of high risk. Many cases presented cerebral (65%) or uterine (55.5%) Doppler flow abnormalities, or both (38%). We noted 10 fetal deaths and decided 7 pregnancy terminations. Malformation and chromosomal defect rate was 16%. We noted 44 (71%) live-births, a very high rate of cesarean section (86%), prematurity (75%), small for gestational age (39%). Forty-five percent of the neonates had a 1-min Apgar score under 7, which dropped to 27% at 5 min. Neonate mortality rate was 6.9% and the total mortality rate was 34% (21/62). Morbidity was significant (7 cases with severe morbidity, 2 cases with chromosomal abnormality of poor prognosis). We compared different sub-groups with a view to looking for some prenatal factors which predict poor neonatal outcome in case of AEDF.

  1. Construction of biocompatible porous tissue scaffold from the decellularized umbilical artery.

    PubMed

    Xin, Yi; Wu, Guanghui; Wu, Man; Zhang, Xiaoxia; Velot, Emilie; Decot, Véronique; Cui, Wei; Huang, Yimin; Stoltz, Jean-Francois; Du, Jie; Li, Na

    2015-01-01

    The scaffolds prepared from the tissue decellularization conserve the porous 3-D structure and provide an optimal matrix for the tissue regeneration. Since decade, the enzymatic digestion, chemical reagent treatment and mechanical actions such as eversion and abrasion have been used to remove the cells from the intact matrix. In this study, we optimized an enzymatic method to decellularize the umbilical artery to construct a 3-D porous scaffold which is suitable for the culture of mesenchymal stem cells (MSCs). The scaffold maintained the interconnected porous structure. It remained the similar high water content 95.3 ± 1% compared to 94.9 ± 0.6% in the intact umbilical artery (p>0.05). The decellularization process decreased the stress from 0.24 ± 0.05 mPa to 0.15 ± 0.06 mPa (p<0.05). However the decellularization did not change the strain of the artery (45 ± 15% vs. 53 ± 10%, p>0.05). When the scaffold was transplanted to the subcutaneous tissue in the wild type mice, there were less T cells appeared in the surrounding tissue which meant the decreased the immunogenicity by decellularization. This scaffold also supported the adhesion and proliferation of the MSCs. In this study, we constructed a biological compatible porous scaffold from the decellularized umbilical artery which may provide a suitable scaffold for cell-matrix interaction studies and for tissue engineering.

  2. Nurses' guide to early detection of umbilical arterial catheter complications in infants.

    PubMed

    Furdon, Susan Arana; Horgan, Michael J; Bradshaw, Wanda Todd; Clark, David A

    2006-10-01

    Umbilical arterial catheters (UAC) are routinely used in the care of critically ill newborns. Complications related to UACs include vascular compromise, hemorrhage, complications related to malposition, severance of the catheter itself, and infection. This article is Part II in a series dedicated to assessing infants with an umbilical catheter. Part I focused on infants with umbilical venous catheters; this article will focus on the physical assessment relevant to infants with an UAC. Complications related to UACs can occur during any phase of treatment: insertion, while indwelling, or after discontinuing the catheter. Review of clinical signs of complications along with clinical photographs, will assist caregivers in promptly recognizing UAC-related complications.

  3. Characteristics of the umbilical artery velocity waveform as function of measurement site.

    PubMed

    Ruissen, C J; von Drongelen, M M; Hoogland, H J; Jager, W; Hoeks, A P

    1990-01-01

    In 30 uncomplicated singleton pregnancies, varying in duration between 24 and 40 weeks, the variability of the flow velocity waveform (FVW) along the course of the umbilical artery was investigated. Blood flow velocities were recorded at 4 locations in the vessel: within the fetal abdomen, 0-5 cm from the origin of the umbilical cord, in the free-floating part, and 0-5 cm from its insertion in the placenta. From the Doppler signals recorded, the pulsatility index (PI) and a parameter for the frequency distribution index (FDI) were calculated. PI values differed among the locations, but no unequivocal tendency could be demonstrated. Statistical analysis, including multiple regression analysis for maternal and menstrual age and fetal heart rate, showed no significant difference in PI and FDI values for any of the 4 locations. It can be concluded that in uncomplicated pregnancies, possible changes in FVW (quantified by PI) along the course of the umbilical artery have no clinical relevance. Therefore, standardization for the sampling site when measuring PI in this vessel seems to be unnecessary.

  4. Relationship between umbilical cord essential fatty acid content and the quality of general movements of healthy term infants at 3 months.

    PubMed

    Bouwstra, Hylco; Dijck-Brouwer, Da Janneke; Decsi, Tamás; Boehm, Günther; Boersma, E Rudy; Muskiet, Frits A J; Hadders-Algra, Mijna

    2006-05-01

    Prenatal essential fatty acid (EFA) status might be an important factor in the development of the central nervous system (CNS). The aim of the present study was to evaluate the relationship between the fatty acid compositions of the umbilical blood vessels at birth, used as a proxy of prenatal EFA status, and quality of general movements (GMs) at 3 mo. Umbilical artery and vein fatty acid compositions were investigated in a mixed group of breastfed infants and infants fed with formula with or without long-chain polyunsaturated fatty acid (LCPUFA) supplementation. At the age of 3 mo, video assessment of the quality of GMs was performed to evaluate neurologic condition. The quality of GMs was scored by assessing the degree of variation, complexity, and fluency. Outcomes were classified as normal-optimal, normal suboptimal, mildly abnormal, and definitely abnormal movements. Information on potential confounders, including the type of postnatal feeding, was collected prospectively. Associations between fatty acid status at birth and quality of GMs were investigated, and multinomial logistic regression analyses were carried out. None of the infants showed definitely abnormal movements. Infants with mildly abnormal GMs had a lower EFA index, lower arachidonic acid (AA) content, higher total n-9 fatty acid, and higher total monounsaturated fatty acid (MUFA) content in the umbilical artery compared with infants with normal GMs. Multivariate analyses confirmed these findings. We conclude that mildly abnormal GMs are associated with a less favorable EFA status in the umbilical artery.

  5. [Interest of lactate micro-dosage in scalp and umbilical cord in cases of abnormal fetal heart rate during labor. Prospective study on 162 patients].

    PubMed

    Paris, A; Maurice-Tison, S; Coatleven, F; Vandenbossche, F; Dallay, D; Horovitz, J

    2012-06-01

    To compare the interest of lactate microanalysis with pH measurement (Gold Standard procedure) in cord blood and fetal scalp blood samples for the assessment of abnormal fetal heart rate (FHR) during labour. A prospective observational study conducted from July 1st 2007 till March 31st 2008 on 162 patients with abnormal FHR during labour. Sampling failure for scalp lactate was less than 1 % compared to a failure of 10.5 % for scalp pH (P<0.001). There was a good correlation between pH and lactates in fetal scalp blood samples and in cord blood samples, between lactate in the last fetal scalp sample and in cord blood. When there was umbilical acidosis (pH≤7.15 or lactate≥5mmol/L), Apgar score at 5 minutes was significantly lower than when there was no acidosis (4.66±3.59 versus 8.35±2.73 for pH ; 6.6±3.77 versus 8.45±2.58 for lactate). The specificity of the lactate in the umbilical cord artery (≥5 mmol/laws) was 76.4 % for predicting an Apgar score at 5 minutes less than 7 ; 79.7 % for predicting the need for immediate neonatal care ; 77.3 % for predicting an hospital stay in neonatal unit. These figures were generally worse but close to those found for a threshold value of umbilical artery pH≤7.15. The values of lactate in cord blood and fetal scalp blood samples were comparable to pH values (Gold standard procedure). This method is easy to perform and is an attractive alternative to pH for monitoring fetal asphyxia. It is our opinion that the combination of the two methods is of interest. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  6. Doppler Audio Signal Analysis as an Additional Tool in Evaluation of Umbilical Artery Circulation.

    PubMed

    Thuring, Ann; Källén, Karin; Brännström, K Jonas; Jansson, Tomas; Maršál, Karel

    2017-10-01

    Purpose  To investigate the predictive capacity of a new method for sound spectrum analysis of Doppler signals recorded from the umbilical artery in high-risk pregnancies. Material and Methods  The retrospective study comprised 127 pregnant women with various pregnancy complications between 23 and 39 gestational weeks. Umbilical artery blood flow velocity waveforms were recorded with Doppler ultrasound and characterized by pulsatility index (PI) and blood flow class (BFC). Doppler audio signals were stored on a digital video recorder and the sound frequency at the energy level 15 dB below its peak (MAX peak-15 dB ) was estimated off-line. The prediction of probability for composite adverse pregnancy outcome (operative delivery for fetal distress, admission to neonatal intensive care unit, perinatal death) was evaluated using the area under the curve (AUC) of the receiver operating characteristics (ROC) curve. Results  With increasing umbilical artery BFC, the MAX peak-15 dB frequencies decreased (p < 0.0001) and the PI increased (p < 0.0001). The ROC AUCs for adverse outcome for MAX peak-15 dB and for PI were 0.842 and 0.836 (p = 0.88), respectively. For the combination of MAX peak-15 dB and PI, the corresponding AUC was 0.894, significantly higher than that of PI (p < 0.03) and of MAX peak-15 dB (p < 0.05). Conclusion  Umbilical artery Doppler sound spectrum analysis might be a useful supplement to PI in the clinical evaluation of fetoplacental circulation. © Georg Thieme Verlag KG Stuttgart · New York.

  7. [Umbilical cord collision in the first trimester in a monoamniotic twin pregnancy--does it really matter?].

    PubMed

    Ropacka-Lesiak, Mariola; Lebioda, Anna; Breborowicz, Grzegorz

    2012-09-01

    A case of an umbilical cord collision diagnosed in the first trimester of a monochorionic monoamniotic twin pregnancy is presented. An intensive surveillance included ultrasound monitoring with color and spectral Doppler and fetal echocardiography. The first signs of fetal distress were observed at 31 weeks of gestation. The brain sparing effect as well as a periodic appearance of the "notch" in the wave forms obtained from the umbilical artery from the collision region were observed. In the first ultrasound scan there were no abnormalities in twin I. In contrast, in twin II a vascular resistance in the umbilical artery was at the upper limit for the gestational age. Five days later, decreased vascular resistance in the middle cerebral artery, which fluctuated at the lower limit, was noticed in twin II. After the next four days, PI in the middle cerebral artery decreased below the lower limit and tricuspid regurgitation appeared. In twin I the vascular resistance in the umbilical artery increased and remained at the upper limit of the reference ranges. Cardiotocographic records did not reveal signs of fetal distress. After a week the signs of brain sparing effect were visible in both fetuses. However, twin II showed features of umbilical cord clamping in the form of abnormal blood flow waveforms in the umbilical artery ("notch"). Therefore, despite the absence of signs of fetal distress in CTG in monochorionic monoamniotic twins with growth discordance of 20% and exponents of periodical clamping of the umbilical cord in twin II at 34 weeks, the decision to perform a caesarean section was made. The patient gave birth to two daughters (twin I: weight 1780g, Ap 10, pH 7.39, 7.40, BE -3.0, -2.6, and twin II: weight 1860g, Ap 10, pH 7.29, 7.35, BE -1.4, -2.4). During the delivery the umbilical cords collision was found at the region close to the body of twins. This case presents the possibility of using ultrasound and Doppler in the early diagnosis, monitoring and

  8. The comparison of umbilical cord arterial blood lactate and pH values for predicting short-term neonatal outcomes.

    PubMed

    Einikyte, Ruta; Snieckuviene, Vilija; Ramasauskaite, Diana; Panaviene, Jurate; Paliulyte, Virginija; Opolskiene, Gina; Kazenaite, Edita

    2017-12-01

    Current clinical practice of assessing neonatal condition is based on evaluation of umbilical cord arterial blood pH value rather than lactate. However, evidence shows that lactate is direct and more predictive measurement than pH or at least of equal importance. This study is to assess and compare umbilical cord arterial lactate and pH values for predicting short-term neonatal outcomes. A retrospective cohort study was conducted at the tertiary level hospital, were arterial umbilical cord blood sampling was collected according to the standard procedures. Neonatal morbidity was registered if at least one of the following conditions was noted: Apgar score at 1 min after delivery was 6 or lower, resuscitation performed, including assisted ventilation and requirement of admission to neonatal intensive care unit. Mothers-newborns pairs were allocated into two groups: newborns exposed to perinatal hypoxia (group 1) and observed as healthy newborns (group 2). Receiver operating characteristics curves (ROC) were generated to assess the predictive ability of pH and lactate for the short-term neonatal outcomes. 901 neonates born at ≥37 weeks of gestation were included. Newborns exposed to perinatal hypoxia (group 1) encompassed 39 (4.3%) patients, and observed as healthy (group 2) - 862 (95.7%). Arterial umbilical cord blood pH in group 1 was 7.160 ± 0.126 as compared to 7.314 ± 0.083 in group 2; p < 0.001. Mean arterial lactate was significantly higher in group 1 than group 2 (6.423 ± 2.335 as compared to 3.600 ± 1.833; p < 0.001). The difference between areas under ROC curves representing pH and lactate was not significant (0.848 and 0.831 respectively; p = 0.6132). Umbilical cord arterial lactate and pH predicted short-term neonatal outcomes with similar efficacies. Copyright © 2017. Published by Elsevier B.V.

  9. Abnormal splenic artery diameter/hepatic artery diameter ratio in cirrhosis-induced portal hypertension

    PubMed Central

    Zeng, Dao-Bing; Dai, Chuan-Zhou; Lu, Shi-Chun; He, Ning; Wang, Wei; Li, Hong-Jun

    2013-01-01

    AIM: To determine an optimal cutoff value for abnormal splenic artery diameter/proper hepatic artery diameter (S/P) ratio in cirrhosis-induced portal hypertension. METHODS: Patients with cirrhosis and portal hypertension (n = 770) and healthy volunteers (n = 31) underwent volumetric computed tomography three-dimensional vascular reconstruction to measure the internal diameters of the splenic artery and proper hepatic artery to calculate the S/P ratio. The cutoff value for abnormal S/P ratio was determined using receiver operating characteristic curve analysis, and the prevalence of abnormal S/P ratio and associations between abnormal S/P ratio and major complications of portal hypertension were studied using logistic regression. RESULTS: The receiver operating characteristic analysis showed that the cutoff points for abnormal splenic artery internal diameter and S/P ratio were > 5.19 mm and > 1.40, respectively. The sensitivity, specificity, positive predictive value, and negative predictive value were 74.2%, 45.2%, 97.1%, and 6.6%, respectively. The prevalence of an abnormal S/P ratio in the patients with cirrhosis and portal hypertension was 83.4%. Patients with a higher S/P ratio had a lower risk of developing ascites [odds ratio (OR) = 0.708, 95%CI: 0.508-0.986, P = 0.041] and a higher risk of developing esophageal and gastric varices (OR = 1.483, 95%CI: 1.010-2.175, P = 0.044) and forming collateral circulation (OR = 1.518, 95%CI: 1.033-2.230, P = 0.034). After splenectomy, the portal venous pressure and maximum and mean portal venous flow velocities were reduced, while the flow rate and maximum and minimum flow velocities of the hepatic artery were increased (P < 0.05). CONCLUSION: The prevalence of an abnormal S/P ratio is high in patients with cirrhosis and portal hypertension, and it can be used as an important marker of splanchnic hemodynamic disturbances. PMID:23483462

  10. The anatomy and development of normal and abnormal coronary arteries.

    PubMed

    Spicer, Diane E; Henderson, Deborah J; Chaudhry, Bill; Mohun, Timothy J; Anderson, Robert H

    2015-12-01

    At present, there is significant interest in the morphology of the coronary arteries, not least due to the increasingly well-recognised association between anomalous origin of the arteries and sudden cardiac death. Much has also been learnt over the last decade regarding the embryology of the arteries. In this review, therefore, we provide a brief introduction into the recent findings regarding their development. In particular, we emphasise that new evidence, derived using the developing murine heart, points to the arterial stems growing out from the adjacent sinuses of the aortic root, rather than the arteries growing in, as is currently assumed. As we show, the concept of outgrowth provides an excellent explanation for several of the abnormal arrangements encountered in the clinical setting. Before summarising these abnormal features, we draw attention to the need to describe the heart in an attitudinally appropriate manner, following the basic rule of human anatomy, rather than describing the cardiac components with the heart in the "Valentine" orientation. We then show how the major abnormalities involving the coronary arteries in humans can be summarised in terms of abnormal origin from the pulmonary circulation, abnormal aortic origin, or fistulous communications between the coronary arteries and the cardiac cavities. In the case of abnormal aortic origin, we highlight those malformations known to be associated with sudden cardiac death.

  11. Prenatal diagnosis of abnormal course of umbilical vein and ductus venosus agenesis: report of three cases.

    PubMed

    Corbacioglu, Aytul; Aslan, Halil; Dagdeviren, Hediye; Ceylan, Yavuz

    2012-01-01

    Ductus venosus connecting the portal and embryonic venous circulation into the inferior vena cava has a crucial role in fetal circulation. The absence of ductus venosus is a rare anomaly, in which the umbilical vein connection to the venous system may be extrahepatic, bypassing the liver or intrahepatic via the portal venous system. We report three cases of ductus venosus agenesis with associated anomalies. In two of them the connection was directly to the right atrium, whereas the umbilical vein drained to the left internal iliac artery in the third case. Copyright © 2012 Wiley Periodicals, Inc.

  12. Management of small-for-gestational-age twins with absent/reversed end diastolic flow in the umbilical artery: outcome of a policy of daily biophysical profile (BPP).

    PubMed

    Kennelly, Máiréad M; Sturgiss, Stephen N

    2007-01-01

    To evaluate a strategy of daily biophysical profile (BPP) for pregnancies with small-for-gestational-age twins and with absent or reversed end diastolic flow (AREDF) in the umbilical artery of one twin and to assess the latency interval between detection and delivery in monochorionic (MC) and dichorionic (DC) twin pregnancy. A search of the Fetal Medicine Database was carried out between 2000 and 2005 at a single tertiary centre to identify all cases with AREDF in the umbilical artery with one small-for-gestational-age twin. Active monitoring with daily BPP was undertaken, once the estimated fetal weights (EFW) was >or= 500 g and at a gestational age of >or= 24 weeks in both twins. Delivery was timed on the basis of an abnormal BPP, two equivocal BPP within 12 h or gestational age of >or= 32(+0) weeks. Twenty-two MC and 17 DC twin pregnancies were identified. There were no fetal losses in the viable actively monitored MC (19) and DC (13) twins. There was a longer latency interval in the MC group at 21.7 days versus 14.4 days in the DC group (p = 0.13). Delivery was indicated for an abnormal BPP (57.8% MC vs 30.8% DC). A strategy of daily BPP can be used to monitor preterm twin fetuses with AREDF, prolonging pregnancy with an acceptable perinatal outcome. Copyright 2007 John Wiley & Sons, Ltd.

  13. The Effect of Prophylactic Phenylephrine and Ephedrine Infusions on Umbilical Artery Blood pH in Women With Preeclampsia Undergoing Cesarean Delivery With Spinal Anesthesia: A Randomized, Double-Blind Trial.

    PubMed

    Higgins, Nicole; Fitzgerald, Paul C; van Dyk, Dominique; Dyer, Robert A; Rodriguez, Natalie; McCarthy, Robert J; Wong, Cynthia A

    2018-06-01

    Spinal anesthesia for cesarean delivery is associated with a high incidence of hypotension. Phenylephrine results in higher umbilical artery pH than ephedrine when used to prevent or treat hypotension in healthy women. We hypothesized that phenylephrine compared to ephedrine would result in higher umbilical artery pH in women with preeclampsia undergoing cesarean delivery with spinal anesthesia. This study was a randomized double-blind clinical trial. Nonlaboring women with preeclampsia scheduled for cesarean delivery with spinal anesthesia at Prentice Women's Hospital of Northwestern Medicine were randomized to receive prophylactic infusions of phenylephrine or ephedrine titrated to maintain systolic blood pressure >80% of baseline. Spinal anesthesia consisted of hyperbaric 0.75% bupivacaine 12 mg, fentanyl 15 µg, and morphine 150 µg. The primary outcome was umbilical arterial blood pH and the secondary outcome was umbilical artery base excess. One hundred ten women were enrolled in the study and 54 per group were included in the analysis. There were 74 and 72 infants delivered in the ephedrine and phenylephrine groups, respectively. The phenylephrine:ephedrine ratio for umbilical artery pH was 1.002 (95% confidence interval [CI], 0.997-1.007). Mean [standard deviation] umbilical artery pH was not different between the ephedrine 7.20 [0.10] and phenylephrine 7.22 [0.07] groups (mean difference -0.02, 95% CI of the difference -0.06 to 0.07; P = .38). Median (first, third quartiles) umbilical artery base excess was -3.4 mEq/L (-5.7 to -2.0 mEq/L) in the ephedrine group and -2.8 mEq/L (-4.6 to -2.2mEq/L) in the phenylephrine group (difference -0.6 mEq/L, 95% CI of the difference -1.6 to 0.3 mEq/L; P = .10). When adjusted for gestational age and infant gender, umbilical artery pH did not differ between groups. There were also no differences in the umbilical artery pH stratified by magnesium therapy or by the severity of preeclampsia. We were unable to demonstrate a

  14. Origins of feeding arteries of hepatocellular carcinoma located near the umbilical fissure of the left hepatic lobe: angiographic evaluation.

    PubMed

    Miyayama, Shiro; Yamashiro, Masashi; Shibata, Yoshihiro; Hashimoto, Masahiro; Yoshida, Miki; Tsuji, Kazunobu; Toshima, Fumihito; Matsui, Osamu

    2012-12-01

    To analyze the origins of the feeding arteries of hepatocellular carcinomas (HCCs) near the umbilical fissure of the left hepatic lobe. Twenty-eight HCCs with a mean ± SD tumor diameter of 3.4 ± 1.0 cm (range 1-4.4 cm) in contact with the right or left side of the umbilical fissure were treated by superselective transcatheter arterial chemoembolization (TACE). The origins of the tumor-feeding arteries were analyzed with arteriograms and computed tomography or cone-beam computed tomography images obtained during and 1 week after TACE. Twenty-one HCC lesions were located in segment 3 and seven were located in segment 4. Of 21 tumors in segment 3, 13 (61.9%) were supplied by the lateral inferior subsegmental artery (A3), three (14.3%) by the medial subsegmental artery (A4), three (14.3%) by both A4 and A3, one (4.8%) by a branch arising from the left lateral hepatic artery, and one (4.8%) by a branch of the right gastric artery. In particular, all tumor-feeding branches arising from A4 were the first branch of A4. Of seven tumors in segment 4, four (57.1%) were supplied by A4 and three (42.9%) by A3. In particular, all tumor-feeding branches arising from A3 were the first branch of A3. This study demonstrates crossover blood supply to HCC lesions located near the umbilical fissure, in addition to direct feeding from a separate branch. In particular, the first branch of the opposite subsegmental artery may feed tumors when crossover blood supply is present.

  15. Origins of Feeding Arteries of Hepatocellular Carcinoma Located Near the Umbilical Fissure of the Left Hepatic Lobe: Angiographic Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miyayama, Shiro, E-mail: s-miyayama@fukui.saiseikai.or.jp; Yamashiro, Masashi; Shibata, Yoshihiro

    2012-12-15

    Purpose: To analyze the origins of the feeding arteries of hepatocellular carcinomas (HCCs) near the umbilical fissure of the left hepatic lobe. Methods: Twenty-eight HCCs with a mean {+-} SD tumor diameter of 3.4 {+-} 1.0 cm (range 1-4.4 cm) in contact with the right or left side of the umbilical fissure were treated by superselective transcatheter arterial chemoembolization (TACE). The origins of the tumor-feeding arteries were analyzed with arteriograms and computed tomography or cone-beam computed tomography images obtained during and 1 week after TACE.ResultsTwenty-one HCC lesions were located in segment 3 and seven were located in segment 4. Ofmore » 21 tumors in segment 3, 13 (61.9%) were supplied by the lateral inferior subsegmental artery (A3), three (14.3%) by the medial subsegmental artery (A4), three (14.3%) by both A4 and A3, one (4.8%) by a branch arising from the left lateral hepatic artery, and one (4.8%) by a branch of the right gastric artery. In particular, all tumor-feeding branches arising from A4 were the first branch of A4. Of seven tumors in segment 4, four (57.1%) were supplied by A4 and three (42.9%) by A3. In particular, all tumor-feeding branches arising from A3 were the first branch of A3. Conclusion: This study demonstrates crossover blood supply to HCC lesions located near the umbilical fissure, in addition to direct feeding from a separate branch. In particular, the first branch of the opposite subsegmental artery may feed tumors when crossover blood supply is present.« less

  16. Endothelial cell expression of adhesion molecules is induced by fetal plasma from pregnancies with umbilical placental vascular disease.

    PubMed

    Wang, Xin; Athayde, Neil; Trudinger, Brian

    2002-07-01

    To test the hypothesis that local production with spill into the fetal circulation of factor(s) injurious to endothelium is responsible for the vascular pathology present when the umbilical artery Doppler study is abnormal. Expression of adhesion molecules is a feature of endothelial cell activation. Case-control study. University teaching hospital. Fetal plasma was collected from 27 normal pregnancies, 39 pregnancies with umbilical placental vascular disease defined by abnormal umbilical artery Doppler and 11 pregnancies with pre-eclampsia and normal umbilical artery Doppler. Isolated and cultured human umbilical vein endothelial cells from normal pregnancies were incubated with fetal plasma from three study groups. mRNA expression of intercellular cell adhesion molecule-1 (ICAM-1), vascular cell adhesion molecule-1 (VCAM-1) and platelet-endothelial cell adhesion molecule-1 (PECAM-1) were assessed by reverse transcription-polymerase chain reaction. To confirm the occurrence of this in vivo, we measured the levels of soluble fractions of sICAM-1, sVCAM-1 and sPECAM-1 in the fetal circulation in the fetal plasma used for endothelial cell incubation. The mRNA expression of ICAM-1 [median 1.1 (interquartile range 0.5-1.9) vs 0.7 (0.3-1.2), P < 0.05] and PECAM-1 [2.1 (1.2-3.0) vs 1.5 (0.7-2.1), P < 0.05] was significantly higher following incubation with fetal plasma from umbilical placental vascular disease compared with the normal group. There was no difference in the expression of VCAM-1 [1.2 (0.9-1.8) vs 1.1 (0.8-1.6), ns]. The group with maternal pre-eclampsia and normal umbilical artery Doppler did not differ from the normal group. In the umbilical placental vascular disease group, the results were similar in the presence or absence of pre-eclampsia. For soluble fractions of the adhesion molecules released into the fetal circulation, we found the levels (ng/mL) of sICAM- I [median 248.5 (interquartile range 197.3-315.7) vs 174.2 (144.5-212.9), P < 0.05] and s

  17. [Rare umbilical anomalies].

    PubMed

    Kysucan, J; Malý, T; Neoral, C

    2010-12-01

    Umbilicus is a scar, which is the place of the previous merger of the fetus with the umbilical cord. After birth, it has no known function, however, unless the umbilical annulus is completely closed, umbilical hernia may occur. Umbilical scar is also an area where may occur a number of anomalies that may be present alone or together with umbilical hernia. Failure of involution leads to persistence of omphalomesenteric duct and urachal remnants. These embryonic remnants may cause more or less significant clinical problems, or may be completely asymptomatic and may be diagnosed at random. The authors present their own group of patients who were diagnosed and dealt with the defect omphalomesenteric duct or urachus. In past 7 years we observed 35 children with these abnormalities. A large group of patients represents incidental findings during elective surgery for umbilical hernia. Another large group are patients with symptomatic or asymptomatic Meckel's diverticulum. The anatomical observations, clinical manifestations, complications and treatment of these anomalies are mentioned. A total of 35 children were found with these birth defects. In 23 cases we observed omphalomesenteric duct disorders and 12 urachal remnants were reported. Of these, 12 abnormalities were found incidentally during elative procedure for umbilical hernia. Asymptomatic or symptomatic Meckel's diverticulum appeared in 16 cases. Surgical treatment included resection or exstirpation, if urachal anomaly was accompanied then partial resection of the bladder vertex was added. Postoperative complications emerged in 4 cases, three times it was ileus from adhesions 6 months after surgery, once postoperative cystitis appeared and was treated conservatively. Birth abnormalities of the umbilicus are relatively rare diseases that may occur in the pediatric population. Omfalomesenteric duct and urachal anomalies constitute a major group of these congenital disorders and are often associated with umbilical

  18. Evaluation of the use of umbilical artery Doppler flow studies and outcome of pregnancies at a secondary hospital.

    PubMed

    Hugo, Elizabeth J C; Odendaal, Hein J; Grove, Debbie

    2007-03-01

    To investigate the use of a personal computer (PC)-based, continuous-wave Doppler machine by a trained midwife at a secondary hospital to assess umbilical artery flow velocity waveforms (FVW) in referred women. Pregnant women referred for suspected poor fetal growth were evaluated from June 2002 through December 2004. The Umbiflow apparatus, consisting of a Pentium 3 PC with an ultrasound transducer plugged into the USB port and software, was used to analyze the FVW of the umbilical artery. Pregnancies in which the resistance index (RI) was <75(th) percentile (P75) were not further evaluated for fetal well-being unless the clinical condition of the mother changed. Pregnancies with an RI >or=P75 were followed up according to a specific protocol. Primary end points were intrauterine death and intrauterine growth restriction. A total of 572 singleton pregnancies were followed up. Significantly more infants were small-for-gestational-age when the RI was >P95 (55.6%) than those between P75 and P95 (41.2%) or P95, respectively. A normal Doppler FVW of the umbilical artery is less likely to be followed by perinatal death.

  19. Coronary artery abnormalities in children with systemic-onset juvenile idiopathic arthritis.

    PubMed

    Lefèvre-Utile, Alain; Galeotti, Caroline; Koné-Paut, Isabelle

    2014-05-01

    Still's disease (Systemic-onset Juvenile Idiopathic Arthritis: SoJIA) is characterised by high-spiking daily fevers, arthritis and evanescent rashes. Diagnosis of Still's disease is often challenging. Infectious diseases and other inflammatory conditions, especially in young children, Kawasaki disease may look similar. Clinicians often rely on echocardiographic evidence of coronary artery abnormalities to differentiate between Kawasaki disease and Still's disease. Coronary artery dilation would typically favour the diagnosis of Kawasaki disease. We present four children with Still's disease and coronary artery abnormalities who were initially misdiagnosed as Kawasaki disease. The first patient had pericarditis and an irregular wall of the left coronary artery, without dilation on echocardiography. The second patient had a left coronary artery dilatation and a pericarditis. The third patient had thickened left coronary artery walls, and the fourth patient had a hyperechogenicity of the left and right coronary arteries. They received IVIG without success. The diagnosis of Still's disease was made secondary with evidence of persistent arthritis. All but one patient finally needed biologic treatments. Coronary abnormalities may be observed during various febrile conditions and do not exclude the diagnosis of Still's disease. Copyright © 2013 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  20. Evidence-based pathology: umbilical cord coiling.

    PubMed

    Khong, T Y

    2010-12-01

    The generation of a pathology test result must be based on criteria that are proven to be acceptably reproducible and clinically relevant to be evidence-based. This review de-constructs the umbilical cord coiling index to illustrate how it can stray from being evidence-based. Publications related to umbilical cord coiling were retrieved and analysed with regard to how the umbilical coiling index was calculated, abnormal coiling was defined and reference ranges were constructed. Errors and other influences that can occur with the measurement of the length of the umbilical cord or of the number of coils can compromise the generation of the coiling index. Definitions of abnormal coiling are not consistent in the literature. Reference ranges defining hypocoiling or hypercoiling have not taken those potential errors or the possible effect of gestational age into account. Even the way numerical test results in anatomical pathology are generated, as illustrated by the umbilical coiling index, warrants a critical analysis into its evidence base to ensure that they are reproducible or free from errors.

  1. Effects of propofol and sevoflurane on isolated human umbilical arteries pre-contracted with dopamine, adrenaline and noradrenaline.

    PubMed

    Gunduz, Ergun; Arun, Oguzhan; Bagci, Sengal Taylan; Oc, Bahar; Salman, Alper; Yilmaz, Setenay Arzu; Celik, Cetin; Duman, Ates

    2015-05-01

    To assess the effects of propofol and sevoflurane on the contraction elicited by dopamine, adrenaline and noradrenaline on isolated human umbilical arteries. Umbilical arteries were cut into endothelium-denuded spiral strips and suspended in organ baths containing Krebs-Henseleit solution bubbled with O2 +CO2 mixture. Control contraction to phenylephrine (10(-5)  M) was recorded. Response curves were obtained to 10(-5)  M dopamine, 10(-5)  M adrenaline or 10(-5)  M noradrenaline. Afterwards, either cumulative propofol (10(-6)  M, 10(-5)  M and 10(-4)  M) or cumulative sevoflurane (1.2%, 2.4% and 3.6%) was added to the organ bath, and the responses were recorded. Responses are expressed percentage of phenylephrine-induced contraction (mean ± standard deviation) (P < 0.05 = significance). Propofol and sevoflurane elicited concentration-dependent relaxations in strips pre-contracted with dopamine, adrenaline and noradrenaline (P < 0.05). Highest (10(-4)  M) concentration of propofol caused significantly higher relaxation compared with the highest (3.6%) concentration of sevoflurane in the contraction elicited by dopamine. High (10(-5)  M) and highest concentrations of propofol caused significantly higher relaxation compared with the high (2.4%) and highest concentrations of sevoflurane on the contraction elicited by adrenaline. High and highest concentrations of sevoflurane caused significantly higher relaxation compared with the high and highest concentrations of propofol on the contraction elicited by noradrenaline. Dopamine, adrenaline and noradrenaline elicit contractions in human umbilical arteries, and noradrenaline causes the highest contraction. Both propofol and sevoflurane inhibit these contractions in a dose-dependent manner. Propofol caused greater relaxation in the contractions elicited by dopamine and adrenaline while sevoflurane caused greater relaxation in the contraction elicited by noradrenaline. © 2014 The Authors

  2. Hemorheological abnormalities in human arterial hypertension

    NASA Astrophysics Data System (ADS)

    Lo Presti, Rosalia; Hopps, Eugenia; Caimi, Gregorio

    2014-05-01

    Blood rheology is impaired in hypertensive patients. The alteration involves blood and plasma viscosity, and the erythrocyte behaviour is often abnormal. The hemorheological pattern appears to be related to some pathophysiological mechanisms of hypertension and to organ damage, in particular left ventricular hypertrophy and myocardial ischemia. Abnormalities have been observed in erythrocyte membrane fluidity, explored by fluorescence spectroscopy and electron spin resonance. This may be relevant for red cell flow in microvessels and oxygen delivery to tissues. Although blood viscosity is not a direct target of antihypertensive therapy, the rheological properties of blood play a role in the pathophysiology of arterial hypertension and its vascular complications.

  3. Abnormalities of the Coronary Arteries in Children: Looking beyond the Origins.

    PubMed

    Saling, Lauren J; Raptis, Demetrios A; Parekh, Keyur; Rockefeller, Toby A; Sheybani, Elizabeth F; Bhalla, Sanjeev

    2017-10-01

    Coronary arterial abnormalities are uncommon findings in children that have profound clinical implications. Although anomalies of the coronary origins are well described, there are many other disease processes that affect the coronary arteries. Immune system-mediated diseases (eg, Kawasaki disease, polyarteritis nodosa, and other vasculiditides) can result in coronary arterial aneurysms, strictures, and abnormal tapering of the vessels. Because findings at imaging are an important component of diagnosis in these diseases, the radiologist's understanding of them is essential. Congenital anomalies may present at varying ages, and findings in hemodynamically significant anomalies, such as fistulas, are key for both diagnosis and preoperative planning. Pediatric heart surgery can result in wide-ranging postoperative imaging appearances of the coronary arteries and also predisposes patients to a multitude of complications affecting the heart and coronary arteries. In addition, although rare, accidental trauma can lead to injury of the coronary arteries, and awareness and detection of these conditions are important for diagnosis in the acute setting. Patients with coronary arterial conditions at presentation may range from being asymptomatic to having findings of myocardial infarction. Recognition of the imaging findings is essential to direct appropriate treatment. © RSNA, 2017.

  4. Fetal Diagnosis of Abnormal Origin of the Left Pulmonary Artery.

    PubMed

    Tretter, Justin T; Tretter, Eric M; Rafii, Daniela Y; Anderson, Robert H; Bhatla, Puneet

    2016-08-01

    Isolated anomalies of the branch pulmonary arteries are rare, more often occurring in the setting of complex congenital heart disease. These isolated anomalies are often not identified in the prenatal period. We describe two cases of isolated anomalies of the left pulmonary artery which were identified on fetal echocardiography and confirmed postnatally, an anomalous left pulmonary artery arising from the base of the left-sided brachiocephalic artery in the setting of a right-sided aortic arch, and a left pulmonary artery sling. These two cases support our current understanding of normal and abnormal development of the extrapericardial arterial vessels and highlight the importance of meticulous attention when sweeping from the three-vessel tracheal view. © 2016, Wiley Periodicals, Inc.

  5. Variations from morning to afternoon of middle cerebral and umbilical artery blood flow, and fetal heart rate variability, and fetal characteristics in the normally developing fetus.

    PubMed

    Avitan, Tehila; Sanders, Ari; Brain, Ursula; Rurak, Dan; Oberlander, Tim F; Lim, Ken

    2018-05-01

    To determine if there are changes in maternal uterine blood flow, fetal brain blood flow, fetal heart rate variability, and umbilical blood flow between morning (AM) and afternoon (PM) in healthy, uncomplicated pregnancies. In this prospective study, 68 uncomplicated singleton pregnancies (mean 35 + 0.7 weeks gestation) underwent a standard observational protocol at both 08:00 (AM) and 13:30 (PM) of the same day. This protocol included Doppler measurements of uterine, umbilical, and fetal middle cerebral artery (MCA) volume flow parameters (flow, HR, peak systolic velocity [PSV], PI, and RI) followed by computerized cardiotocography. Standard descriptive statistics, χ 2 and t tests were used where appropriate. P < .05 was considered significant. A significant increase in MCA flow and MCA PSV was observed in the PM compared to the AM. This was accompanied by a fall in MCA resistance. Higher umbilical artery resistance indices were also observed in the PM compared to AM. In contrast, fetal heart rate characteristics, maternal uterine artery Doppler flow and resistance indices did not vary significantly between the AM and PM. In normal pregnancies, variations in fetal cerebral and umbilical blood flow parameters were observed between AM and PM independent of other fetal movements or baseline fetal heart rate. In contrast, uterine flow parameters remained stable across the day. These findings may have implications for the use of serial Doppler parameters used to guide clinical management in high-risk pregnancies. © 2017 Wiley Periodicals, Inc.

  6. Predicting umbilical artery pH during labour: Development and validation of a nomogram using fetal heart rate patterns.

    PubMed

    Ramanah, Rajeev; Omar, Sikiyah; Guillien, Alicia; Pugin, Aurore; Martin, Alain; Riethmuller, Didier; Mottet, Nicolas

    2018-06-01

    Nomograms are statistical models that combine variables to obtain the most accurate and reliable prediction for a particular risk. Fetal heart rate (FHR) interpretation alone has been found to be poorly predictive for fetal acidosis while other clinical risk factors exist. The aim of this study was to create and validate a nomogram based on FHR patterns and relevant clinical parameters to provide a non-invasive individualized prediction of umbilical artery pH during labour. A retrospective observational study was conducted on 4071 patients in labour presenting singleton pregnancies at >34 gestational weeks and delivering vaginally. Clinical characteristics, FHR patterns and umbilical cord gas of 1913 patients were used to construct a nomogram predicting an umbilical artery (Ua) pH <7.18 (10th centile of the study population) after an univariate and multivariate stepwise logistic regression analysis. External validation was obtained from an independent cohort of 2158 patients. Area under the receiver operating characteristics (ROC) curve, sensitivity, specificity, positive and negative predictive values of the nomogram were determined. Upon multivariate analysis, parity (p < 0.01), induction of labour (p = 0.01), a prior uterine scar (p = 0.02), maternal fever (p = 0.02) and the type of FHR (p < 0.01) were significantly associated with an Ua pH <7.18 (p < 0.05). Apgar score at 1, 5 and 10 min were significantly lower in the group with an Ua pH <7.18 (p < 0.01). The nomogram constructed had a Concordance Index of 0.75 (area under the curve) with a sensitivity of 57%, a specificity of 91%, a negative predictive value of 5% and a positive predictive value of 99%. Calibration found no difference between the predicted probabilities and the observed rate of Ua pH <7.18 (p = 0.63). The validation set had a Concordance Index of 0.72 and calibration with a p < 0.77. We successfully developed and validated a nomogram to predict Ua pH by

  7. Comparison between transdermal nitroglycerin and sildenafil citrate in intrauterine growth restriction: effects on uterine, umbilical and fetal middle cerebral artery pulsatility indices.

    PubMed

    Trapani, A; Gonçalves, L F; Trapani, T F; Franco, M J; Galluzzo, R N; Pires, M M S

    2016-07-01

    To evaluate the effects of transdermal nitroglycerin (GTN) and sildenafil citrate on Doppler velocity waveforms of the uterine (UtA), umbilical (UA) and fetal middle cerebral (MCA) arteries in pregnancies with intrauterine growth restriction (IUGR). This was a prospective study of 35 singleton pregnancies (gestational age, 24-31 weeks) with IUGR and abnormal UtA and UA Doppler waveforms. We compared maternal arterial blood pressure and Z-scores of the pulsatility index (PI) of UtA, UA and fetal MCA before and after application of a transdermal GTN patch (average dose, 0.4 mg/h), oral sildenafil citrate (50 mg) or placebo. Statistical analysis was performed by ANOVA for paired samples. There was a significant decrease in UtA-PI after application of GTN (21.0%) and sildenafil citrate (20.4%). A significant reduction in UA-PI was also observed for both GTN (19.1%) and sildenafil citrate (18.2%). There was no difference in UtA- and UA-PI when the GTN and sildenafil groups were compared. No changes in Doppler velocimetry were observed in the placebo group and no significant change in MCA-PI was observed in any group. Maternal arterial blood pressure decreased with administration of both GTN and sildenafil citrate in those with pre-eclampsia. The use of transdermal GTN or sildenafil citrate in pregnancies with IUGR is associated with a significant reduction in both UtA and UA Doppler PI, as well as maternal arterial blood pressure. Neither drug affected the MCA-PI. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  8. Carboxyhemoglobin levels in umbilical cord blood of women with pre-eclampsia and intrauterine growth restriction.

    PubMed

    Yusuf, Kamran; Kamaluddeen, Majeeda; Wilson, R Douglas; Akierman, Albert

    2012-11-01

    Pre-eclampsia (PE) and intrauterine growth restriction (IUGR) are associated with abnormal placentation. Heme oxygenase (HO) and carbon monoxide (CO) are involved in normal placental development and function and vasomotor control in the placenta. The objective of our study was to measure CO levels, as assessed by carboxyhemoglobin (COHb) levels in the umbilical cord arterial blood of women with PE, normotensive IUGR (<10th percentile for birth weight), and normotensive pregnancies with appropriate-for-gestational age (AGA) infants. We prospectively analyzed COHb levels in the umbilical arterial blood of women with PE, normotensive IUGR, and normotensive AGA pregnancies. Exclusion criteria included cigarette smoke exposure, hemolytic disorders, a positive direct anti-globulin test, chronic hypertension, fever, and any significant medical illness. COHb levels were measured using the ABL 725 blood gas analyzer. There were 41 women in the normotensive AGA group, 42 in the PE group, and 36 in the normotensive IUGR group. Maternal age, mode of delivery, gravidity, parity, and gender of the infants were similar in the three groups. Gestational age and birth weight were significantly higher in the normotensive AGA group compared with the other two groups. COHb levels were significantly lower in the PE group compared with the normotensive AGA group (0.38±0.06% vs. 0.77±0.11%, P<0.05). COHb levels, although lower in the normotensive IUGR group compared with the normotensive AGA group, did not reach statistical significance. Our data suggests the HO-CO system may have a role in the pathogenesis of PE. We also, for the first time, provide information on umbilical arterial COHb levels in normotensive IUGR pregnancies.

  9. Cardiac surgery during pregnancy: continuous fetal monitoring using umbilical artery Doppler flow velocity indices.

    PubMed

    Mishra, Manisha; Sawhney, Ravindra; Kumar, Anil; Bapna, Kumar Ramesh; Kohli, Vijay; Wasir, Harpreet; Trehan, Naresh

    2014-01-01

    The fetal death rate associated with cardiac surgery with cardiopulmonary bypass (CPB) is as high as 9.5-29%. We report continuous monitoring of fetal heart rate and umbilical artery flow-velocity waveforms by transvaginal ultrasonography and their analyses in relation to events of the CPB in two cases in second trimester of pregnancy undergoing mitral valve replacement. Our findings suggest that the transition of circulation from corporeal to extracorporeal is the most important event during surgery; the associated decrease in mean arterial pressure (MAP) at this stage potentially has deleterious effects on the fetus, which get aggravated with the use of vasopressors. We suggest careful management of CPB at this stage, which include partial controlled CPB at initiation and gradual transition to full CPB; this strategy maintains high MAP and avoids the use of vasopressors. Maternal and fetal monitoring can timely recognize the potential problems and provide window for the required treatment.

  10. Study on the relationship between the expression of IGF-1 in umbilical cord blood and abnormal glucose metabolism during pregnancy.

    PubMed

    Liu, K; Wu, H-Y; Xu, Y-H

    2017-02-01

    To explore the relationship between the expression of insulin-like growth factor-1 (IGF-1) in neonatal umbilical cord blood and abnormal glucose metabolism during pregnancy. We have selected 63 cases of delivery randomly, term birth and maternal from January 2015 to January 2016 in our hospital, gestational diabetes mellitus for Group A, abnormal gestational glucose tolerance for Group B and normal for Group C with 21 cases in each group. The venous blood samples were collected from all the pregnant females 2 weeks before delivery, and the levels of HbA1c in serum were detected by Elisa method. During the delivery, the umbilical cord blood was collected and the levels of IGF-1 were measured by double site immune enzyme analysis. The neonatal weight was recorded and the correlation analysis was made in respect of the measurement results. The level of HbA1c in Group A was significantly higher than that in Group C (p < 0.05); IGF-1 level and neonatal weight of Group B were significantly higher than that of Group C (p < 0.05), IGF-1 has a significant correlation with neonatal weight in Group C, and HbA1c and IGF-1 were positively correlated (p < 0.05); IGF-1 was positively correlated with neonatal weight in Group A and Group B (p < 0.05). There was a significant positive correlation between the IGF-1 level of neonatal umbilical cord blood and the neonatal weight (p < 0.05). Also, the level of HbA1c was positively correlated with the level of IGF-1 in neonatal umbilical cord blood at the end of pregnancy (p < 0.05). The expression level of IGF-1 in the final stage of pregnant females can be detected to predict the expression level of IGF-1 in newborn infants and then the growth status of the fetus can be obtained.

  11. Fetal bilateral renal agenesis, phocomelia, and single umbilical artery associated with cocaine abuse in early pregnancy.

    PubMed

    Kashiwagi, Maki; Chaoui, Rabih; Stallmach, Thomas; Hürlimann, Sandra; Lauper, Urs; Hebisch, Gundula

    2003-11-01

    Maternal cocaine abuse in pregnancy is associated with complications such as intrauterine growth retardation, abruptio placentae, and preterm delivery. We report what is, to our knowledge, the first published observation of fetal bilateral renal agenesis associated with a vascular disruption syndrome comprising upper limb reduction defect and a single umbilical artery following maternal cocaine abuse in early pregnancy. This constellation in a fetus aborted at 18 weeks extends the spectrum of complications possibly associated with cocaine abuse in pregnancy. Copyright 2003 Wiley-Liss, Inc.

  12. Critical care for patients with congenital abnormalities of the coronary arteries.

    PubMed

    Flores, Saul; Moore, Ryan A; Statile, Christopher J; Michelfelder, Erik C; Wanstrath, Shawna G; Knilans, Timothy K; Morales, David L; Cooper, David S

    2015-12-01

    Congenital abnormalities of the coronary arteries in the absence of structural heart disease account for a small but interesting percentage of cardiac lesions in children. Their presentation may vary from incidental identification to aborted/sudden cardiac death. Patients with aborted sudden death episodes will require significant support if they develop extensive ischaemic myocardial injury. Ultimately, surgical repair should be carried out as soon as haemodynamic stability is attained and the neurological status is evaluated. The aims of this article were to provide a review of congenital abnormalities of the coronary arteries most commonly seen in children in the ICU as well as to review the current critical-care management thereof.

  13. Shear-wave elastography - virtual touch tissue quantification of fetal placentas with a single umbilical artery.

    PubMed

    Arslan, Harun; Tolunay, Harun Egemen; Cim, Numan; Boza, Barış; Yavuz, Alpaslan; İlik, İbrahim; Sahin, Hanim Guler; Yildizhan, Recep

    2018-02-25

    In this study, we aimed to evaluate the elasticities of fetal placentas with a single umbilical artery using the Virtual Touch Tissue Quantification (VTTQ) technique. Pregnant women with fetuses with a single umbilical artery (SUA) and pregnant women with fetuses having three vessel cord (3VC) at 18-22 weeks of gestation were enrolled in the research. The placentas were evaluated and divided into three equal parts as the inner 1/3 of the placenta (fetal edge), the outer 1/3 of the placenta (maternal edge) and the central 1/3 of the placenta (central part). Shear-wave velocity (SWV) measurements were used in the elastographic evaluation of placentas by VTTQ. Forty pregnant women were included in the study (n = 20 SUA, n = 20 three vessel cord pregnant women). The placental Acoustic Radiation Force Impulse (VTTQ) of the placenta regarding SWV measurement values of the fetal edge of the placenta in the fetuses with SUA and the control group were 0.876 and 0.957 m/sec, respectively. A significant statistical difference was found between the groups regarding the measurement of the stiffness of fetal placenta (p = 0.021). There was no significant difference between the measured stiffness values of the central or outer region of the placentas. In this study, we found lower SWV scores for the fetal edge of the placenta with SUA. This finding may reflect tissue elasticity level, and we hope that the use of the VTTQ technique may contribute to predicting the pregnancy-related morbidities of fetuses with SUA in the future.

  14. Infection of internal umbilical remnant in foals by Clostridium sordellii.

    PubMed

    Ortega, J; Daft, B; Assis, R A; Kinde, H; Anthenill, L; Odani, J; Uzal, F A

    2007-05-01

    Omphalitis and the resulting septicemia contribute to perinatal mortality in several animal species. In foals, the most important causes of omphalitis are Escherichia coli and Streptococcus zooepidemicus. However to date, no information has been published about the role of Clostridium sordellii in these infections. In this paper, we describe 8 cases of perinatal mortality in foals associated with internal umbilical remnant infection by C. sordellii. The foals studied were between 12 and 21 days old at the time of death, and various breeds were represented in the group. Five of the foals were male and 3 were female. The diagnosis was established on the basis of the detection of C. sordellii by 3 methods (culture, fluorescent antibody test, and immunohistochemistry) and on gross and histopathologic findings. All foals had acute peritonitis, and the internal umbilical remnant was thickened by edema, hemorrhage, and fibrosis. A moderate amount of serosanguinous fluid with fibrin strands was present in the pericardial sac and pleural cavity. Histopathologically, the urachus and umbilical arterial walls were thickened by edema and exhibited hemorrhage, fibrin, and leukocytic infiltration. Gram-positive bacterial rods were observed in subepithelial areas of the urachus, the adventicia of umbilical arteries, and interstitium of the internal umbilical remnant. On the basis of these findings, we suggest that C. sordellii should be considered in the differential diagnosis for infections of the internal umbilical remnant in foals.

  15. Reversible arterial redistribution in a fetus with true umbilical cord knot: case report and review of literature.

    PubMed

    Navolan, Dan Bogdan; Sas, Ioan; Grigoraş, Dorin; Moldovan, Mihaela; Cîrlan, Casius; Angheloiu Rîcă, Daiana Elena; Levai, Codrina Mihaela

    2015-01-01

    Umbilical cord knot (UCK) affects around 1% of pregnancies and tightening of UCK is a very rare and highly unpredictable complication of pregnancy that can lead to fetal demise or neonatal death. The majority of authors agree that very little could be done to prevent fetal deaths in pregnancies with undiagnosed tight UCK. We herein report the case of a 39-year-old, gravidity five, parity three, pregnant woman at 40 weeks and five days age of pregnancy, whose pregnancy evolved without complications and who was admitted to hospital for the management of the birth. Although the last ultrasound examination before birth showed a reversible arterial redistribution in the fetus dependent on the postural status of the pregnant women and other factors associated with umbilical cord knot were present, the diagnosis was missed because of the factors' non-specificity. After a spontaneous labor without complications a dead male fetus, weight 3300 g, without heartbeat, Apgar score 0 was delivered. Macroscopic and microscopic findings confirmed that the cause of neonatal death was asphyxia caused by a tight UCK. The aim of our paper is to present the dramatic outcome of a pregnancy with a fetus with a tight umbilical cord knot (UCK), to bring to attention the signs that suggested the diagnosis, and to review the literature on this subject.

  16. The crying sign: the winking umbilical cord

    PubMed Central

    Smith, Aisling M; Healy, David B; Ryan, C Anthony; Dempsey, Eugene M

    2015-01-01

    A preterm baby girl, born at 34 weeks gestation, with features of Beckwith-Wiedemann syndrome was noted to have a relatively large umbilical stump. No fetal abnormalities had been detected on anatomy scan at 28 weeks and only mild polyhydramnios and macrosomia were noted on a 32-week ultrasound scan. Although there was no obvious omphalocoele, clinical assessment of the umbilical cord revealed an abdominal wall defect through which bowel would protrude into the umbilicus when the infant was crying. In keeping with an abdominal wall defect α-fetoprotein was found to be elevated. Surgical consultation advised conservative management. Subsequently, detachment of the umbilical cord occurred 1 week postdischarge and a large umbilical hernia persists. Genetic analysis confirmed a diagnosis of Beckwith-Wiedemann syndrome. PMID:25820111

  17. A necropsy and histomorphometric study of abnormalities in the course of the vertebral artery associated with ossified stylohyoid ligaments.

    PubMed Central

    Johnson, C P; Scraggs, M; How, T; Burns, J

    1995-01-01

    AIMS--To establish whether abnormalities in the course of the vertebral artery occur and whether they are relevant to arterial injury associated with head and neck movements. METHODS--Twenty vertebral arteries were carefully dissected at necropsy and abnormalities in course were noted, along with any other bony or cartilaginous cervical anomalies. The effect of head and neck movement on these vessels was studied before a detailed histomorphometric examination was undertaken on sections of the excised arteries. RESULTS--Five vessels had an abnormal course. One vessel entered the transverse foramina of the fifth cervical vertebra rather than the sixth, but was otherwise normal. In two subjects both vertebral arteries were abnormal in the upper cervical portion with, in each case, a straight left vertebral artery and a right vertebral artery with a deficient loop, closely applied to the atlanto-axial joint. Both of these subjects also had completely ossified stylohyoid ligaments and the arteries visibly stretched with modest head and neck movements. Histology revealed variable degrees of smooth muscle disarray in the tunica media of two of the arteries with loop deficiencies. The circumference of one of the straight arteries was smaller than expected but in all other measured histomorphometric parameters these vessels appeared normal. CONCLUSIONS--Vertebral artery loops are deficient in a number of subjects. This finding is important given the recently described biomechanical susceptibility of the vertebral artery to longitudinal extension and may explain the smooth muscle changes, in that this may represent attempts at arterial wall remodelling. Subjects with such loop deficiencies may be more susceptible to a variety of head and neck insults and such abnormalities should be sought at necropsy in subjects who die as a result of fatal vertebral artery injury. Images PMID:7560170

  18. Bupivacaine inhibits large conductance, voltage- and Ca2+- activated K+ channels in human umbilical artery smooth muscle cells

    PubMed Central

    Martín, Pedro; Enrique, Nicolás; Palomo, Ana R. Roldán; Rebolledo, Alejandro; Milesi, Veronica

    2012-01-01

    Bupivacaine is a local anesthetic compound belonging to the amino amide group. Its anesthetic effect is commonly related to its inhibitory effect on voltage-gated sodium channels. However, several studies have shown that this drug can also inhibit voltage-operated K+ channels by a different blocking mechanism. This could explain the observed contractile effects of bupivacaine on blood vessels. Up to now, there were no previous reports in the literature about bupivacaine effects on large conductance voltage- and Ca2+-activated K+ channels (BKCa). Using the patch-clamp technique, it is shown that bupivacaine inhibits single-channel and whole-cell K+ currents carried by BKCa channels in smooth muscle cells isolated from human umbilical artery (HUA). At the single-channel level bupivacaine produced, in a concentration- and voltage-dependent manner (IC50 324 µM at +80 mV), a reduction of single-channel current amplitude and induced a flickery mode of the open channel state. Bupivacaine (300 µM) can also block whole-cell K+ currents (~45% blockage) in which, under our working conditions, BKCa is the main component. This study presents a new inhibitory effect of bupivacaine on an ion channel involved in different cell functions. Hence, the inhibitory effect of bupivacaine on BKCa channel activity could affect different physiological functions where these channels are involved. Since bupivacaine is commonly used during labor and delivery, its effects on umbilical arteries, where this channel is highly expressed, should be taken into account. PMID:22688134

  19. Neonatal Arterial Morphology Is Related to Body Size in Abnormal Human Fetal Growth.

    PubMed

    Olander, Rasmus F W; Sundholm, Johnny K M; Ojala, Tiina H; Andersson, Sture; Sarkola, Taisto

    2016-09-01

    Restriction in fetal growth is associated with cardiovascular disease in adulthood. It is unclear whether abnormal intrauterine growth influences arterial morphology during the fetal or neonatal stage. The objective was to study the regional arterial morphology with respect to gestational age and abnormal fetal body size. We studied body anthropometrics and arterial morphology and physiology in 174 neonates born between 31 and 42 weeks of gestation, including neonates with birth weights appropriate, small, and large for age, with very high resolution vascular ultrasound (35-55 MHz). In simple linear regressions, parameters of body size (body weight, body surface area, and organ circumference) and gestational age were statistically significantly associated with common carotid, brachial, femoral arterial parameters (lumen diameter [LD], wall layer thickness [intima-media thickness and intima-media-adventitia thickness], and carotid artery wall stress [CAWS]). Male sex was statistically significantly associated with LD and CAWS. In multiple linear regression models, body size, gestational age, and sex explained a large proportion of the arterial variance (R( 2) range, 0.37-0.47 for LD; 0.09-0.35 for intima-media thickness; 0.21-0.41 for intima-media-adventitia thickness; and 0.23 for CAWS; all models P<0.001). Arterial wall layer thickness, LDs, and CAWS were independently and strongly predicted by body size, and no effect of maternal disease was observed when added to the models. Gestational age and male sex were also independently but more weakly associated with arterial LDs and CAWS (P<0.01), but not with arterial wall layers. These results indicate that the intrauterine growth of fetal arterial LD and wall layer thickness are primarily attributed to body growth overall. LD and CAWS show weaker association with gestational age and sex. © 2016 American Heart Association, Inc.

  20. Influence of the measurement location on the resistance index in the umbilical arteries: a hemodynamic approach.

    PubMed

    Vieyres, P; Durand, A; Patat, F; Descamps, P; Gregoire, J M; Pourcelot, D; Pourcelot, L

    1991-12-01

    A computer model was used to study the primary factors generating the reduction in resistance index, (S-D)/S, values observed by ultrasonic Doppler measurements in the umbilical artery, from the fetal insertion to the placental insertion (S represents the amplitude of the systolic peak and D the amplitude of the diastolic peak). This hemodynamic approach shows that the placental resistance is the primary factor, the viscosity and the cord length playing secondary roles. Clinically, the position of the measurement along the cord is an important factor. To increase the sensitivity of the index, the Doppler measurement must be performed near the fetal insertion, whereas a measurement near the placental insertion will make the Doppler examination more specific.

  1. Coronary artery anomalies overview: The normal and the abnormal

    PubMed Central

    Villa, Adriana DM; Sammut, Eva; Nair, Arjun; Rajani, Ronak; Bonamini, Rodolfo; Chiribiri, Amedeo

    2016-01-01

    The aim of this review is to give a comprehensive and concise overview of coronary embryology and normal coronary anatomy, describe common variants of normal and summarize typical patterns of anomalous coronary artery anatomy. Extensive iconography supports the text, with particular attention to images obtained in vivo using non-invasive imaging. We have divided this article into three groups, according to their frequency in the general population: Normal, normal variant and anomaly. Although congenital coronary artery anomalies are relatively uncommon, they are the second most common cause of sudden cardiac death among young athletes and therefore warrant detailed review. Based on the functional relevance of each abnormality, coronary artery anomalies can be classified as anomalies with obligatory ischemia, without ischemia or with exceptional ischemia. The clinical symptoms may include chest pain, dyspnea, palpitations, syncope, cardiomyopathy, arrhythmia, myocardial infarction and sudden cardiac death. Moreover, it is important to also identify variants and anomalies without clinical relevance in their own right as complications during surgery or angioplasty can occur. PMID:27358682

  2. The intra-umbilical approach in umbilical hernia.

    PubMed

    Arslan, Sukru; Korkut, Ercan

    2014-02-01

    To investigate the "intra-umbilical incision", a smaller incision compared to classic incisions, in cases of umbilical hernia, and which we believe will contribute to patient satisfaction in aesthetic terms, and also the practicability of such operations. The umbilical margins of eight patients with an umbilical hernia were marked between the levels of 6 and 12 o'clock, and a median intra-umbilical skin incision was performed between these two points. In some cases, where exploration could not be performed sufficiently, the incision was extended horizontally from 6 or 12 o'clock. Hernia repair and mesh placement was then performed using an intra-umbilical approach. Patients were investigated according to the defect size and requirement for intra-umbilical incision extension. No requirement for intra-umbilical incision was encountered in six patients with a facial defect diameter smaller than 4 cm, while the incision had to be extended in two patients with defects greater than 4 cm. The intra-umbilical approach in umbilical hernia surgery is aesthetically superior to classical approaches and is a practicable technique.

  3. A case report of umbilical ring constriction with application of amnioinfusion.

    PubMed

    Tokunaka, Mayumi; Hasegawa, Junichi; Nakamura, Masamitsu; Hamada, Shoko; Matsuoka, Ryu; Ichizuka, Kiyotake; Sekizawa, Akihiko; Okai, Takashi

    2013-07-01

    This is a case report of a pregnant 38-year-old primigravida woman. Due to severe fetal growth restriction and oligohydramnios, she was referred to our tertiary perinatal center at 24 weeks' gestation. To rule out chromosomal abnormalities and facilitate ultrasound evaluation of fetal morphology, we performed amniocentesis and subsequent amnioinfusion. Thereafter, a precise ultrasound examination revealed no obvious fetal morphological abnormalities except for a hyper-coiled cord and marginal placenta previa. During expectant management, the amount of amniotic fluid was maintained at 20-26 mm for a few days; however, the pregnancy resulted in intrauterine fetal death after 26 weeks + 5 days of gestation. The stillborn infant weighed 530 g (-3.3 SD) and had no obvious external abnormalities apart from umbilical ring constriction. Although a postmortem autopsy was not performed, it is suspected that the fetal growth restriction and the intrauterine fetal death were associated with the hyper-coiled cord and the umbilical ring constriction. It is thought that umbilical ring constriction might therefore be an irreversible fatal condition in cases with a hyper-coiled cord.

  4. The Intra-Umbilical Approach in Umbilical Hernia

    PubMed Central

    Arslan, Sukru; Korkut, Ercan

    2014-01-01

    Objective: To investigate the “intra-umbilical incision”, a smaller incision compared to classic incisions, in cases of umbilical hernia, and which we believe will contribute to patient satisfaction in aesthetic terms, and also the practicability of such operations. Materials and Methods: The umbilical margins of eight patients with an umbilical hernia were marked between the levels of 6 and 12 o’clock, and a median intra-umbilical skin incision was performed between these two points. In some cases, where exploration could not be performed sufficiently, the incision was extended horizontally from 6 or 12 o’clock. Hernia repair and mesh placement was then performed using an intra-umbilical approach. Results: Patients were investigated according to the defect size and requirement for intra-umbilical incision extension. No requirement for intra-umbilical incision was encountered in six patients with a facial defect diameter smaller than 4 cm, while the incision had to be extended in two patients with defects greater than 4 cm. Conclusion: The intra-umbilical approach in umbilical hernia surgery is aesthetically superior to classical approaches and is a practicable technique. PMID:25610291

  5. Two congenital coronary abnormalities affecting heart function: anomalous origin of the left coronary artery from the pulmonary artery and congenital left main coronary artery atresia.

    PubMed

    Xiao, Yanyan; Jin, Mei; Han, Ling; Ding, Wenhong; Zheng, Jianyong; Sun, Chufan; Lyu, Zhenyu

    2014-01-01

    The anomalous origin of the left coronary artery (LCA) from the pulmonary artery (ALCAPA) and congenital left main coronary artery atresia (CLMCA-A) are two kinds of very rare coronary heart diseases which affect heart function profoundly. This study aimed to retrospectively illustrate the clinical features and therapy experience of ALCAPA and CLMCA-A patients. From April 1984 to July 2012, in Beijing Anzhen Hospital, 23 patients were diagnosed with ALCAPA and 4 patients with CLMCA-A. We summarized the clinical data of the 27 cases and retrospectively analyzed the clinical manifestation, diagnosis, and treatments of these two kinds of congenital coronary abnormalities. The 23 patients (13 males and 10 females, aged ranging from 2.5 months to 65 years) identified with ALCAPA were classified into infantile type (age of onset younger than 12 months, 16 cases) and adult type (age of onset older than 12 months, 7 cases). Four patients were diagnosed with CLMCA-A (three males and one female, aged ranging from 3 months to 2 years). The main clinical manifestations of infantile-type ALCAPA and CLMCA-A include repeated respiratory tract infection, heart failure, dyspnea, feeding intolerance, diaphoresis, and failure to thrive. And these two congenital coronary abnormalities might be misdiagnosed as endocardial fibroelastosis, dilated cardiomyopathy, and acute myocardial infarction. As for the adult-type ALCAPA, cardiac murmurs and discomfort of the precordial area are the most common presentations and might be misdiagnosed as coronary heart disease, myocarditis, or patent ductus arteriosus. In ECG examination: Infantile-type ALCAPA and CLMCA-A showed abnormal Q waves with T wave inversion in leads I, avL, and V4-V6, especially in lead avL. However, ECG of adult-type ALCAPA lacked distinct features. In chest radiography: pulmonary congestion and cardiomegaly were the most common findings in infantile-type ALCAPA and CLMCA-A, while pulmonary artery segment dilation was more

  6. Doppler ultrasound of the maternal uterine arteries: disappearance of abnormal waveforms and relation to birthweight and pregnancy outcome.

    PubMed

    Campbell, S; Black, R S; Lees, C C; Armstrong, V; Peacock, J L

    2000-08-01

    To assess whether the gestation at which abnormal uterine artery waveforms disappear is related to birthweight and complications of pregnancy. A prospective study of outcome of pregnancy after a uterine artery Doppler screening program set in an inner city teaching hospital. One thousand five hundred and twenty-four consecutive women attending the Obstetric Department for a routine anomaly scan at between 19 and 21 weeks gestation had maternal uterine arteries assessed using color wave Doppler. Those women in whom the flow was deemed abnormal were recalled for a further scan at 24-26 weeks gestation. The main outcome measures were birthweight, gestation at delivery and incidence of pre eclampsia. The women in whom the uterine artery blood flow was normal at 20 weeks had babies with significantly higher mean birthweight than those who normalized between 20 and 24-26 weeks gestation ('late normalizers') after adjustment for confounding factors; gestational age, maternal height, parity, ethnic group and smoking (mean difference=173 g, 95% confidence intervals 42 to 303 g). The timing of trophoblast invasion, as reflected by abnormal uterine artery waveforms, may have an effect on birthweight.

  7. Pulmonary Arterial Hypertension With Abnormal V/Q Single-Photon Emission Computed Tomography.

    PubMed

    Chan, Kenneth; Ioannidis, Stefanos; Coghlan, John G; Hall, Margaret; Schreiber, Benjamin E

    2017-10-16

    This study aimed to evaluate the incidence and clinical outcomes of abnormal ventilation/perfusion (V/Q) single-photon emission computed tomography (SPECT) without thromboembolism, especially in patients with group I pulmonary arterial hypertension (PAH). American Heart Association/American College of Cardiology and European Society of Cardiology guidelines recommend V/Q scan for screening for chronic thromboembolic pulmonary hypertension. The significance of patients with abnormal V/Q SPECT findings but no thromboembolism demonstrated in further investigations remained unclear. A distinct pattern of global patchy changes not typical of thromboembolism is recognized, but guidelines for reporting these in the context of PAH are lacking. A total of 136 patients who underwent V/Q SPECT and right-sided heart catheterization showing mean pulmonary arterial pressure ≥25 mm Hg were included. V/Q SPECT findings were reported using European Association of Nuclear Medicine criteria for pulmonary embolism followed by computed tomography pulmonary angiography screening for positive thromboembolism and further invasive pulmonary angiography for distal thromboembolism. The abnormal V/Q SPECT images were further analyzed according to perfusion pattern into focal or global perfusion defects. V/Q SPECT showed thromboembolic disease in 44 patients, but 19 of these patients had no thromboembolism demonstrated by pulmonary angiography. Among these patients, 15 of 19 (78.9%) had group I PAH, and the majority had diffuse, patchy perfusion defects. After redefining V/Q SPECT images according to the perfusion pattern, those patients with global perfusion defects had higher mean pulmonary arterial pressure compared with patients with focal perfusion defects and normal scans (mean difference +13.9 and +6.2 mm Hg, respectively; p = 0.0002), as well as higher pulmonary vascular resistance (mean difference +316.6 and +226.3 absolute resistance units, respectively; p = 0

  8. Persistent Umbilical Discharge from an Omphalomesenteric Duct Cyst Containing Gastric Mucosa

    PubMed Central

    Tamilselvan, Kanimozhi; Mohan, Arunodaya; Cheslyn-Curtis, Sarah; Eisenhut, Michael

    2012-01-01

    Umbilical discharge in infancy is often attributed to infection or an umbilical granuloma. It is important to investigate if such a discharge is due to an underlying congenital abnormality because corrective surgical intervention may then be required. We present the first case of an infant with a persistent umbilical discharge from an omphalomesenteric duct cyst. The discharge was associated with periumbilical dermatitis. The dermatitis was most likely due to irritation of the skin by gastric acid produced by the ectopic gastric mucosa contained in the omphalomesenteric duct cyst. Both discharge and dermatitis resolved after surgical removal of the cyst. PMID:22693676

  9. Three-dimensional HDlive imaging of an umbilical cord cyst.

    PubMed

    Inubashiri, Eisuke; Nishiyama, Naomi; Tatedo, Sayuri; Minami, Hiina; Saitou, Atushi; Watanabe, Yukio; Sugawara, Masaki

    2018-04-01

    Umbilical cord cysts (UCC) are a rare congenital malformation. Previous reports have suggested that the second- and third-trimester UCC may be associated with other structural anomalies or chromosomal abnormalities. Therefore, high-quality imaging is clinically important for the antenatal diagnosis of UCC and to conduct a precise anatomical survey of intrauterine abnormalities. There have been few reports of antenatal diagnosis of UCC with the conventional two- and three-dimensional ultrasonography. In this report, we demonstrate the novel visual depiction of UCC in utero with three-dimensional HDlive imaging, which helps substantially with prenatal diagnosis. A case with an abnormal placental mass at 16 weeks and 5 days of gestation was observed in detail using HDlive. HDlive revealed very realistic images of the intrauterine abnormality: the oval lesion was smooth with regular contours and a homogenous wall at the site of cord insertion on the placenta. In addition, we confirmed the absent of umbilical cord, placental, and fetal structural anomalies. Here, we report a case wherein HDlive may have provided clinically valuable information for prenatal diagnosis of UCC and offered a potential advantage relative to the conventional US.

  10. Umbilical cannulation optimizes circuit flows in premature lambs supported by the EXTra-uterine Environment for Neonatal Development (EXTEND).

    PubMed

    Hornick, Matthew A; Davey, Marcus G; Partridge, Emily A; Mejaddam, Ali Y; McGovern, Patrick E; Olive, Aliza M; Hwang, Grace; Kim, Jenny; Castillo, Orlando; Young, Kathleen; Han, Jiancheng; Zhao, Sheng; Connelly, James T; Dysart, Kevin C; Rychik, Jack; Peranteau, William H; Flake, Alan W

    2018-05-01

    Bronchopulmonary dysplasia is a disease of extreme prematurity that occurs when the immature lung is exposed to gas ventilation. We designed a novel 'artificial womb' system for supporting extreme premature lambs (called EXTEND) that obviates gas ventilation by providing oxygen via a pumpless arteriovenous circuit with the lamb submerged in sterile artificial amniotic fluid. In the present study, we compare different arteriovenous cannulation strategies on EXTEND, including carotid artery/jugular vein (CA/JV), carotid artery/umbilical vein (CA/UV) and umbilical artery/umbilical vein (UA/UV). Compared to CA/JV and CA/UV cannulation, UA/UV cannulation provided significantly higher, physiological blood flows to the oxygenator, minimized flow interruptions and supported significantly longer circuit runs (up to 4 weeks). Physiological circuit blood flow in UA/UV lambs made possible normal levels of oxygen delivery, which is a critical step toward the clinical application of artificial womb technology. EXTEND (EXTra-uterine Environment for Neonatal Development) is a novel system that promotes physiological development by maintaining the premature lamb in a sterile fluid environment and providing gas exchange via a pumpless arteriovenous oxygenator circuit. During the development of EXTEND, different cannulation strategies evolved with the aim of improving circuit flow. The present study examines how different cannulation strategies affect EXTEND circuit haemodynamics in extreme premature lambs. Seventeen premature lambs were cannulated at gestational ages 105-117 days (term 145-150 days) and supported on EXTEND for up to 4 weeks. Experimental groups were distinguished by cannulation strategy: carotid artery outflow and jugular vein inflow (CA/JV; n = 4), carotid artery outflow and umbilical vein inflow (CA/UV; n = 5) and double umbilical artery outflow and umbilical vein inflow (UA/UV; n = 8). Circuit flows and pressures were measured continuously. As we

  11. Prevalence and prognostic impact of electrocardiographic abnormalities in outpatients with extracardiac artery disease.

    PubMed

    Hysing, Per; Jonason, Tommy; Leppert, Jerzy; Hedberg, Pär

    2017-11-24

    Identifying cardiac disease in patients with extracardiac artery disease (ECAD) is essential for clinical decision-making. Electrocardiography (ECG) is an easily accessible tool to unmask subclinical cardiac disease and to risk stratify patient with or without manifest cardiovascular disease (CV). We aimed to examine the prevalence and prognostic impact of ECG changes in outpatients with ECAD. Outpatients with carotid or lower extremity artery disease (n = 435) and community-based controls (n = 397) underwent resting ECG. The patients were followed during a median of 4·8 years for CV events (hospitalization or death caused by ischaemic heart disease, cardiac arrest, heart failure, or stroke). ECG abnormalities were classified according to the Minnesota Code. Major (33% versus 15%, P<0·001) but not minor ECG abnormalities (23% versus 26%, P = 0·42) were significantly more common in patients versus controls. During the follow-up, 141 patients experienced CV events. Both major ECG abnormalities [hazard ratio (HR) 1·58, 95% confidence interval (CI) 1·11-2·25, P = 0·012] and any ECG abnormalities (HR 1·57, 95% CI 1·06-2·33, P = 0·024) were significantly associated with CV events after adjustment for potential risk factors. In conclusion, ECG abnormalities were common in these outpatients with ECAD. Major and any ECG abnormalities were independent predictors of CV events. Addition of easily accessible ECG information might be useful in risk stratification for such patients. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  12. [Clinical efficacy and safety of uterine artery chemoembolization in abnormal placental implantation complicated with postpartum hemorrhage].

    PubMed

    Chen, Yao-ting; Xu, Lin-feng; Sun, Hong-liang; Li, Hui-qing; Hu, Ren-mei; Tan, Qi-yin

    2010-04-01

    To investigate the safety and clinical efficacy of uterime artery chemoembolization in postpartum hemorrhage (PPH) caused by abnormal placental implantation. Between December 2006 and September 2009, there were 23 cases of abnormal placental implantation with PPH in our hospital, among which 9 presented with continuous small amount of vaginal bleeding and 14 with acute excessive bleeding. The average bleeding time was (8+/-6) d and the mean blood loss was (980+/-660) ml. Abnormal placental implantation was confirmed by color Doppler ultrasound (CD-US) in all cases, the internal iliac artery angiography was performed to identify the uterine artery and bilateral uterine artery chemoembolization (UACE) with methotrexate (MTX) and gelfoam particles to the distal end of uterine artery was conducted after. CD-US rechecked all patients within 48 h after UACE and those patients with blurred margins between placenta and uterus and abnormal blood flow (>1 cmx1 cm) received ultrasonic-guided per vagina MTX multipoint injections. All cases were followed up for 3-26 months (average 12 months) to observe vaginal bleeding, placenta tissue discharge, serum human chorionic gonadotropin (hCG), uterine involution, menses, and side-effects or complications. (1) Curative effect: These 23 cases underwent 24 procedures of UACE successfully and vaginal bleeding ceased at an average of (3.5+/-1.3) min after UACE. Reduced blood flow in the placental implantation area was detected under CD-US after UACE. Among the 23 patients, wterine curettage was required in 16 cases due to retained placenta tissues with the mean blood loss of (40+/-28) ml during the operation, 2 underwent subtotal hysterectomy and confirmed to be placenta percreta by pathology examination, and placenta tissues were spontaneously discharged completely in 5 cases. Totally, 91% of the patients (21/23) reserved their uterus. (2) FOLLOW-UP: the serum hCG reduced to normal within 1-13 d after the placenta tissue were evacuated

  13. [Compression of trachea and esophagus by abnormal course of the left pulmonary artery (author's transl)].

    PubMed

    Lang, D; Hofstetter, R; Müssig, G; von Bernuth, G

    1975-11-01

    A three months old infant with abnormal origine and course of the left pulmonary artery is described. The course of the left pulmonary artery between oesophagus and trachea causes narrowing of the distal trachea leading to in- and expiratory stridor. A ventral indentation of the oesophagus, visible on the lateral plane of an oesophageal roentgenogram, is characteristic for the anomaly which can be proven by pulmonary angiography.

  14. Umbilical endometriosis associated with large umbilical hernia. Case report.

    PubMed

    Stojanovic, M; Radojkovic, M; Jeremic, L; Zlatic, A; Stanojevic, G; Janjic, D; Mihajlovic, S; Dimov, I; Kostov, M; Zdravkovic, M; Stojanovic, M

    2014-01-01

    Umbilical endometriosis is a rare condition, usually following laparoscopic and surgical procedures involving the umbilicus.Spontaneous umbilical endometriosis occurring without any previous abdominal or uterine surgery is extremely rare. The maximal depth of penetration of the umbilical endometriosis described is up to fascial level. There have been only two cases of endometriosis reported arising within umbilical hernia. The authors report a case of a patient with spontaneous umbilical endometriosis associated with a large umbilical hernia, treated by surgical excision and mesh repair of the abdominal wall. To the best of our knowledge, this is the first described case of the association of umbilical endometriosis with a large umbilical hernia that requires prosthetic mesh repair of the abdominal wall defect. Celsius.

  15. The timing of umbilical cord clamping at birth: physiological considerations.

    PubMed

    Hooper, Stuart B; Binder-Heschl, Corinna; Polglase, Graeme R; Gill, Andrew W; Kluckow, Martin; Wallace, Euan M; Blank, Douglas; Te Pas, Arjan B

    2016-01-01

    While it is now recognized that umbilical cord clamping (UCC) at birth is not necessarily an innocuous act, there is still much confusion concerning the potential benefits and harms of this common procedure. It is most commonly assumed that delaying UCC will automatically result in a time-dependent net placental-to-infant blood transfusion, irrespective of the infant's physiological state. Whether or not this occurs, will likely depend on the infant's physiological state and not on the amount of time that has elapsed between birth and umbilical cord clamping (UCC). However, we believe that this is an overly simplistic view of what can occur during delayed UCC and ignores the benefits associated with maintaining the infant's venous return and cardiac output during transition. Recent experimental evidence and observations in humans have provided compelling evidence to demonstrate that time is not a major factor influencing placental-to-infant blood transfusion after birth. Indeed, there are many factors that influence blood flow in the umbilical vessels after birth, which depending on the dominating factors could potentially result in infant-to-placental blood transfusion. The most dominant factors that influence umbilical artery and venous blood flows after birth are lung aeration, spontaneous inspirations, crying and uterine contractions. It is still not entirely clear whether gravity differentially alters umbilical artery and venous flows, although the available data suggests that its influence, if present, is minimal. While there is much support for delaying UCC at birth, much of the debate has focused on a time-based approach, which we believe is misguided. While a time-based approach is much easier and convenient for the caregiver, ignoring the infant's physiology during delayed UCC can potentially be counter-productive for the infant.

  16. [Umbilical blood-gas status at cesarean section for breech presentation: a comparison with vertex presentation].

    PubMed

    Haruta, M; Saeki, N; Naka, Y; Funato, T; Ohtsuki, Y

    1989-10-01

    Umbilical blood-gas status at elective cesarean section with oxygen inhalation for breech presentation (25 cases) was compared with that for vertex presentation (25 cases), so as to confirm the security of full-term breech fetuses delivered by cesarean section under spinal anesthesia. Umbilical arterial oxygen levels were significantly lower in the breech group (Mean PO2:18.9 mmHg; SO2:37.3%; Oxygen content:7.6 ml/dl). The number of hypoxemic fetuses was significantly higher in the breech group (the breech: 7; the vertex; 0). The other umbilical blood-gas values revealed no significant differences between the breech and vertex groups, and were within normal limits in both groups. Oxygen extraction in the breech (Mean: 49.0%) was higher than that in the vertex (32.9%). Therefore decreased umbilical blood flow in the breech was suggested. The incidence of depression at 1 minute after delivery in the breech infants (24%) was significantly higher than that in the vertex infants (0%). It became obvious in the breech that as the interval between the uterine incision and delivery increased, umbilical arterial blood tended to acidosis and the 1 minute Apgar score decreased. Cesarean section for breech presentation requires sufficient and optimal incisions of the abdominal wall and uterus as well as a skillful manual delivery technique, because the fetus or neonate should be protected against asphyxia resulting from umbilical compression and prolonged delivery interval.

  17. Impact of maternal HIV on umbilical cord lactate measurement at delivery in a South African labor ward.

    PubMed

    Allanson, Emma R; Pattinson, Robert C; Nathan, Elizabeth A; Dickinson, Jan E

    2018-06-01

    To assess umbilical artery lactate levels and perinatal outcomes among women with and without HIV infection. The present prospective cohort study recruited women planning to undergo vaginal delivery at Kalafong Hospital, South Africa, between March 3 and November 12, 2014. Umbilical artery lactate levels were measured and perinatal outcome data were recorded. Outcome analyses were stratified by maternal HIV status, and a subgroup analysis was performed where women with a CD4 count below 350 × 10 6 cells/L were compared with women without HIV. In total, 936 women with singleton fetuses were enrolled. Maternal HIV status was available for 897 (95.8%) participants, of whom 202 (21.6%) had HIV infections. Overall, 186 (92.1%) women with HIV infections received prophylaxis or treatment. There was no difference between participants with and without HIV infections in the preterm delivery rate (P=0.770), mode of delivery (P=0.354), neonatal resuscitation rate (P=0.717), 1- or 5-minute Apgar scores below 7 (P=0.353), or the rate of having an umbilical artery lactate level above 5.45 mmol/L (P=0.301). Similarly, there were no differences in outcomes in the subgroup analysis of women with a CD4 count below 350 × 10 6 cells/L. Umbilical artery lactate levels and perinatal outcomes were found to be comparable between patients with and without HIV infections in a South African setting. © 2018 International Federation of Gynecology and Obstetrics.

  18. Fetal MRI as a complementary technique after prenatal diagnosis of persistent vitelline artery in an otherwise normal fetus.

    PubMed

    Bravo, Coral; De León-Luis, Juan; Gámez, Francisco; Ruiz, Yolanda; Pintado, Pilar; Pérez, Ricardo; Ortiz-Quintana, Luis

    2013-10-01

    Prenatal ultrasound is the standard for the diagnosis of fetal anomalies. However, fetal MRI has emerged as a valuable diagnosis tool to complete the study of fetal malformations. Type II single umbilical artery results from the absence of both umbilical arteries and persistence of the vitelline artery. It has been described only in fetuses with sirenomelia or caudal regression syndrome. We report a favorable outcome in a normal fetus in which prenatal ultrasound and MRI showed a single umbilical artery arising from the aorta. The etiology of such a finding and its possible consequences are discussed. Copyright © 2013 Wiley Periodicals, Inc.

  19. Abnormal neurodevelopmental outcomes are very likely in cases of bilateral neonatal arterial ischaemic stroke.

    PubMed

    Jin, Ju Hyun; Shin, Jeong Eun; Lee, Soon Min; Eun, Ho Seon; Park, Min Soo; Park, Kook In; Namgung, Ran

    2017-02-01

    Neonatal arterial ischaemic stroke (AIS) is an important cause of severe neurological disability. This study aimed to analyse the clinical manifestations and outcomes of AIS patients. We enrolled neonates with AIS admitted to Severance Children's Hospital and Gangnam Severance Hospital between 2008 and 2015. AIS was confirmed using magnetic resonance imaging (MRI). We retrospectively reviewed the clinical manifestations, MRI findings, electroencephalography (EEG) findings and neurodevelopmental outcomes. The study comprised 29 neonates (18 boys). The mean follow-up period was 15.4 months (range 6-44 months), and the mean age at diagnosis was 8.1 days. Seizure was the most common symptom (66%). Bilateral involvement was more common than unilateral involvement (52%). The middle cerebral artery was the most commonly identified territory (79%). Abnormal EEG findings were noted in 93% of the cases. Neurodevelopment was normal in 11 (38%) patients, while cerebral palsy and delayed development were noted in eight (28%) and six (21%) patients, respectively. Patients with bilateral involvement were very likely to have abnormal neurodevelopmental outcomes. Our study showed that abnormal neurodevelopmental outcomes were very likely after cases of neonatal AIS with bilateral involvement, and clinicians should consider early and more effective interventions in such cases. ©2016 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  20. Term Neonate with Atypical Hypoxic-Ischemic Encephalopathy Presentation: A Case Report

    PubMed Central

    Townley, Nick; McNellis, Emily; Sampath, Venkatesh

    2017-01-01

    We describe a case of atypical hypoxic-ischemic encephalopathy (HIE) in a neonate following a normal pregnancy and delivery who was found to have an umbilical vein thrombosis. The infant arrived to our center with continuous bicycling movement of her lower extremities. She had a continuous electroencephalogram that showed burst suppression and magnetic resonance imaging of the brain showed diffusely abnormal cerebral cortical/subcortical diffusion restriction which may be secondary hypoxic-ischemic injury. Interestingly, a pathology report noted a focal umbilical vein thrombosis appearing to have compressed an umbilical artery with associated arterial dissection and hematoma. Our case illustrates how umbilical venous or arterial thrombosis may be associated with HIE and refractory seizures. PMID:28852582

  1. Term Neonate with Atypical Hypoxic-Ischemic Encephalopathy Presentation: A Case Report.

    PubMed

    Townley, Nick; McNellis, Emily; Sampath, Venkatesh

    2017-07-01

    We describe a case of atypical hypoxic-ischemic encephalopathy (HIE) in a neonate following a normal pregnancy and delivery who was found to have an umbilical vein thrombosis. The infant arrived to our center with continuous bicycling movement of her lower extremities. She had a continuous electroencephalogram that showed burst suppression and magnetic resonance imaging of the brain showed diffusely abnormal cerebral cortical/subcortical diffusion restriction which may be secondary hypoxic-ischemic injury. Interestingly, a pathology report noted a focal umbilical vein thrombosis appearing to have compressed an umbilical artery with associated arterial dissection and hematoma. Our case illustrates how umbilical venous or arterial thrombosis may be associated with HIE and refractory seizures.

  2. Umbilical necrosis rates after abdominal-based microsurgical breast reconstruction.

    PubMed

    Ricci, Joseph A; Kamali, Parisa; Becherer, Babette E; Curiel, Daniel; Wu, Winona; Tobias, Adam M; Lin, Samuel J; Lee, Bernard T

    2017-07-01

    Umbilical stalk necrosis represents a rare, yet important complication after abdominal-based microsurgical breast reconstruction, which is both underrecognized and understudied in the literature. Once identified, umbilical reconstruction can be an extremely challenging problem. All consecutive breast free flaps at a single institution from February 2004 to February 2016 were reviewed, excluding non-abdominal-based flaps. Patients were divided based on the development of umbilical necrosis postoperatively. Demographics, surgical characteristics, and other complications were compared between the groups. A total of 918 patients met the inclusion criteria, with 29 developing umbilical necrosis identified (3.2%). Patients developing necrosis tended to be older (49.4 yrs versus 52.9 yrs; P < 0.01); have higher BMI (31.3 versus 27.8; P < 0.01); and were more likely to be smokers (27.5% versus 11.6%; P = 0.01). Umbilical necrosis was also associated with increased flap weight (830 g versus 656 g; P < 0.01), decreased time of perforator dissection (151 min versus 169 min; P = 0.02); bilateral cases (68.9% versus 44.7%; P < 0.01), and increased number of perforators per flap (2.5 versus 2.2; P = 0.03). There was no association with flap type (deep inferior epigastric perforator, superficial inferior epigastric artery, or free TRAM), diabetes, previous abdominal surgery, or use of preoperative imaging. Umbilical necrosis was not associated with any concomitant complications. Umbilical stalk necrosis was found to occur in 3.2% of patients and was associated with several preoperative comorbidities and intraoperative characteristics. This information should help influence intraoperative decision-making to prevent the development of this undesirable complication. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Doppler ultrasonographic assessment of maternal and fetal arteries during normal feline gestation.

    PubMed

    Blanco, P G; Rodríguez, R; Olguín, S; Rube, A; Tórtora, M; Gobello, C

    2014-04-01

    The aim of this study was to describe Doppler parameters of uterine, umbilical, fetal abdominal aorta, fetal renal and fetal internal carotid arteries, as well as fetal heart rate (FHR), during normal feline gestation. Fifteen, 1-4 years of age, weighing 2.5-3.9kg, domestic short-hair pregnant queens, which were born in our institutional cat colony were included in this study. Color and pulsed-wave Doppler evaluations of uterine arteries were performed every 10 days (Day 0, 10, 20, 30, 40, 50, 60) from mating. Fetal Doppler and M-mode ultrasonography were performed to assess umbilical, fetal abdominal aorta, fetal renal, fetal internal carotid arteries and FHR. Both peak systolic velocity (PSV) and end diastolic velocity (EDV) of uterine artery increased up to parturition (P<0.01), while resistance index (RI) decreased from Day 10 onwards (P<0.01). From Day 40 onwards, RI of umbilical artery diminished, while PSV and EDV augmented (P<0.01). Fetal abdominal aorta (P<0.01), renal (P<0.01) and internal carotid (P<0.01) arteries diminished their RI from Days 40, 60 and 40 onwards, respectively. Both PSV and EDV of these three arteries increased progressively. Fetal heart rate was first registered on Day 20 when it began to increase up to Day 40 and then diminished to the end of gestation (P<0.01). It is concluded that blood flow of uterine, umbilical, fetal abdominal aorta, fetal renal and fetal internal carotid arteries progressively increased during normal feline pregnancy, while FHR rose to mid gestation and then decreased up to parturition. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Changes in Doppler flow velocity waveforms and fetal size at 20 weeks gestation among cigarette smokers.

    PubMed

    Kho, E M; North, R A; Chan, E; Stone, P R; Dekker, G A; McCowan, L M E

    2009-09-01

    To compare umbilical and uterine artery Doppler waveforms and fetal size at 20 weeks between smokers and nonsmokers. Prospective cohort study. Auckland, New Zealand and Adelaide, Australia. Nulliparous participants in the Screening for Pregnancy Endpoints (SCOPE) study. Self-reported smoking status was determined at 15 +/- 1 weeks' gestation. At the 20 +/- 1 week anatomy scan, uterine and umbilical Doppler resistance indices (RI) and fetal measurements were compared between smokers and nonsmokers. Umbilical and mean uterine artery Doppler RI values, abnormal umbilical and uterine Doppler (RI > 90th centile) and fetal biometry. Among the 2459 women, 248 (10%) were smokers. Smokers had higher umbilical RI [0.75 (SD 0.06) versus 0.73 (0.06), P < 0.0001] and mean uterine RI [0.59 (0.09) versus 0.56 (0.10), P < 0.0001]. They were twice as likely to have an abnormal umbilical Doppler at 20 weeks compared with nonsmokers [n = 35 (14.6%) versus n = 156 (7.2%), OR 2.21, 95% CI 1.49-3.27]. This effect remained significant after adjusting for age, ethnicity, marital status, employment and BMI (adjusted OR 1.62, 95% CI 1.03-2.54). Smokers were more likely to have an abnormal mean uterine RI [n = 33 (13.7%) versus n = 198 (9.2%), OR 1.57, 95% CI 1.06-2.33], but this association was not significant after adjusting for confounders. Fetuses of women who smoked had a small reduction in femur length and estimated weight compared with nonsmokers. At 20 weeks' gestation, women who smoke have higher umbilical artery RI, a surrogate measure for an abnormal placental villous vascular tree. This may contribute to later fetal growth restriction among smokers. Further research is needed to explore the clinical significance of these findings.

  5. Laser-assisted fibrinogen bonding of umbilical vein grafts.

    PubMed

    Oz, M C; Williams, M R; Souza, J E; Dardik, H; Treat, M R; Bass, L S; Nowygrod, R

    1993-06-01

    Despite success with autologous tissue welding, laser welding of synthetic vascular prostheses has not been possible. The graft material appears inert and fails to allow the collagen breakdown and electrostatic bonding that results in tissue welding. To develop a laser welding system for graft material, we repaired glutaraldehyde-tanned human umbilical cord vein graft incisions using laser-assisted fibrinogen bonding (LAFB) technology. Modified umbilical vein graft was incised transversely (1.2 cm). Incisions were repaired using sutures, laser energy alone, or LAFB. For LAFB, indocyanine green dye was mixed with human fibrinogen and the compound applied with forceps onto the weld site prior to exposure to 808 nm diode laser energy (power density 4.8 W/cm 2). Bursting pressures for sutured repairs (126.6 +/- 23.4 mm Hg) were similar to LAFB anastomoses (111.6 +/- 55.0 mm Hg). No evidence of collateral thermal injury to the graft material was noted. In vivo evaluation of umbilical graft bonding with canine arteries demonstrates that LAFB can reliably reinforce sutured anastomoses. The described system for bonding graft material with laser exposed fibrinogen may allow creation or reinforcement of vascular anastomoses in procedures where use of autologous tissue is not feasible.

  6. Intractable Electrical Storm After Coronary Artery Bypass Grafting Originating in Abnormal Purkinje Fibers.

    PubMed

    Tokunaga, Chiho; Tsukada, Toru; Sakamoto, Hiroaki; Naruse, Yoshihisa; Yoshida, Kentaro; Sekiguchi, Yukio; Imai, Akito; Aonuma, Kazutaka; Hiramatsu, Yuji

    2016-01-01

    Electrical storm is a rare but critical complication following revascularization in patients with ischemic heart disease. We report the case of a 67-year-old man who developed drug refractory intractable electrical storm after emergent coronary artery bypass grafting for ischemic cardiomyopathy. The electrical storm was successfully eliminated by percutaneous endocardial radiofrequency catheter ablation targeting the abnormal Purkinje-related triggering ventricular premature contractions in a low-voltage zone. © 2015 Wiley Periodicals, Inc.

  7. Normal and Abnormal Development of the Intrapericardial Arterial Trunks in Man and Mouse

    PubMed Central

    Anderson, Robert H.; Chaudhry, Bill; Mohun, Timothy J.; Bamforth, Simon D.; Hoyland, Darren; Phillips, Helen M.; Webb, Sandra; Moorman, Antoon F.J.; Brown, Nigel A.; Henderson, Deborah J.

    2014-01-01

    Aims The definitive cardiac outflow channels have three components: the intrapericardial arterial trunks; the arterial roots with valves; and the ventricular outflow tracts. We studied the normal and abnormal development of the most distal of these, the arterial trunks, comparing findings in mouse and man. Methods and Results Using lineage tracing and three-dimensional visualization by episcopic reconstruction and scanning electron microscopy, we studied embryonic day 9.5 to 12.5 mouse hearts, clarifying the development of the outflow tracts distal to the primordia of the arterial valves. We characterize a transient aortopulmonary foramen, located between the leading edge of a protrusion from the dorsal wall of the aortic sac and the distal margins of the two outflow cushions. The foramen is closed by fusion of the protrusion, with its cap of neural crest cells, with the neural crest cell-filled cushions; the resulting structure then functioning transiently as an aortopulmonary septum. Only subsequent to this closure is it possible to recognize, more proximally, the previously described aortopulmonary septal complex. The adjacent walls of the intrapericardial trunks are derived from the protrusion and distal parts of the outflow cushions, while the lateral walls are formed from intrapericardial extensions of pharyngeal mesenchyme derived from the second heart field. Conclusions We provide, for the first time, objective evidence of the mechanisms of closure of an aortopulmonary foramen that exists distally between the lumens of the developing intrapericardial arterial trunks. Our findings provide insights into the formation of aortopulmonary windows and the variants of common arterial trunk. PMID:22499773

  8. Fetal demise by umbilical cord around abdomen and stricture.

    PubMed

    Tan, Shun-Jen; Chen, Chi-Huang; Wu, Gwo-Jang; Chen, Wei-Hwa; Chang, Cheng-Chang

    2010-01-01

    Umbilical cord abnormalities are accepted as conditions associated with intrauterine fetal demise (IUFD), and umbilical cord stricture is most frequently encountered. In addition, although cord entanglement with multiple loops rarely increases the perinatal mortality, it is associated with a significant increase in variable kind of morbidity such as growth restriction. We describe a 27-year-old woman, with a missed abortion history at about 10 weeks' gestation in her first pregnancy, who presented to our outpatient department at 34 4/7 weeks of gestation due to decreased fetal activity during the preceding week. No fetal heart activity and blood flow had been detected by ultrasonography and pulsed-wave Doppler. A demised fetus with umbilical cord stricture and three loops around abdomen was delivered and was weighted 1,830 g that was below the tenth percentile for the gestational age. Either umbilical cord stricture or entanglement around the body can affect the development of the fetus and even be lethal. The former might play a more important role in this case. Their etiology and the sequence of the events are still undetermined, and additional evaluation such as autopsy and further research may be needed. In addition, counsel and frequent fetal surveillance should be done in patients with previous IUFD attributed to cord stricture during next pregnancy because of undetermined risk of recurrence.

  9. Hyperintense Vessels on T2-PROPELLER-FLAIR in Patients with Acute MCA Stroke: Prediction of Arterial Stenosis and Perfusion Abnormality.

    PubMed

    Ahn, S J; Suh, S H; Lee, K-Y; Kim, J H; Seo, K-D; Lee, S

    2015-11-01

    Fluid-attenuated inversion recovery hyperintense vessels in stroke represent leptomeningeal collateral flow. We presumed that FLAIR hyperintense vessels would be more closely associated with arterial stenosis and perfusion abnormality in ischemic stroke on T2-PROPELLER-FLAIR than on T2-FLAIR. We retrospectively reviewed 35 patients with middle cerebral territorial infarction who underwent MR imaging. FLAIR hyperintense vessel scores were graded according to the number of segments with FLAIR hyperintense vessels in the MCA ASPECTS areas. We compared the predictability of FLAIR hyperintense vessels between T2-PROPELLER-FLAIR and T2-FLAIR for large-artery stenosis. The interagreement between perfusion abnormality and FLAIR hyperintense vessels was assessed. In subgroup analysis (9 patients with MCA horizontal segment occlusion), the association of FLAIR hyperintense vessels with ischemic lesion volume and perfusion abnormality volume was evaluated. FLAIR hyperintense vessel scores were significantly higher on T2-PROPELLER-FLAIR than on T2-FLAIR (3.50 ± 2.79 versus 1.21 ± 1.47, P < .01), and the sensitivity for large-artery stenosis was significantly improved on T2-PROPELLER-FLAIR (93% versus 68%, P = .03). FLAIR hyperintense vessels on T2-PROPELLER-FLAIR were more closely associated with perfusion abnormalities than they were on T2-FLAIR (κ = 0.64 and κ = 0.27, respectively). In subgroup analysis, FLAIR hyperintense vessels were positively correlated with ischemic lesion volume on T2-FLAIR, while the mismatch of FLAIR hyperintense vessels between the 2 sequences was negatively correlated with ischemic lesion volume (P = .01). In MCA stroke, FLAIR hyperintense vessels were more prominent on T2-PROPELLER-FLAIR compared with T2-FLAIR. In addition, FLAIR hyperintense vessels on T2-PROPELLER-FLAIR have a significantly higher sensitivity for predicting large-artery stenosis than they do on T2-FLAIR. Moreover, the areas showing FLAIR hyperintense vessels on T2-PROPELLER

  10. Placental pathology in early intrauterine growth restriction associated with maternal hypertension.

    PubMed

    Veerbeek, J H W; Nikkels, P G J; Torrance, H L; Gravesteijn, J; Post Uiterweer, E D; Derks, J B; Koenen, S V; Visser, G H A; Van Rijn, B B; Franx, A

    2014-09-01

    To identify key pathological characteristics of placentas from pregnancies complicated by early intrauterine growth restriction, and to examine their relations with maternal hypertensive disease and umbilical artery Doppler waveform abnormalities. Single-center retrospective cohort study of singleton pregnancies with abnormal umbilical artery Doppler flow patterns resulting in a live birth <34 weeks of a baby with a weight <10th percentile for gestational age. Umbilical artery end diastolic flow was classified as being either present or absent/reversed (AREDF). Data were stratified into intrauterine growth restriction with or without hypertensive disease and pathological characteristics were compared between these various conditions according to predefined scoring criteria. Among 164 placentas studied, we found high rates of characteristic histopathological features that were associated with intrauterine growth restriction, including infarction (>5% in 42%), chronic villitis (21%), chronic chorioamnionitis (36%), membrane necrosis (20%), elevated nucleated red blood cells (89%), increased syncytial knotting (93%), increased villous maturation (98%), fetal thrombosis (32%) and distal villous hypoplasia (35%). Chronic inflammation of fetal membranes and syncytial knotting were more common in women with concomitant hypertensive disease as compared to women with normotensive IUGR (p < 0.05). Placentas from women with umbilical artery AREDF were more likely to show increased numbers of nucleated red blood cells and distal villous hypoplasia (p < 0.05). Placentas of women with early IUGR show high rates of several histological aberrations. Further, concomitant maternal hypertension is associated with characteristic inflammatory changes and umbilical artery AREDF with signs of chronic hypoxia. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Early functional and morphological brain disturbances in late-onset intrauterine growth restriction.

    PubMed

    Starčević, Mirta; Predojević, Maja; Butorac, Dražan; Tumbri, Jasna; Konjevoda, Paško; Kadić, Aida Salihagić

    2016-02-01

    To determine whether the brain disturbances develop in late-onset intrauterine growth restriction (IUGR) before blood flow redistribution towards the fetal brain (detected by Doppler measurements in the middle cerebral artery and umbilical artery). Further, to evaluate predictive values of Doppler arterial indices and umbilical cord blood gases and pH for early functional and/or morphological brain disturbances in late-onset IUGR. This cohort study included 60 singleton term pregnancies with placental insufficiency caused late-onset IUGR (IUGR occurring after 34 gestational weeks). Umbilical artery resistance index (URI), middle cerebral artery resistance index (CRI), and cerebroumbilical (C/U) ratio (CRI/URI) were monitored once weekly. Umbilical blood cord samples (arterial and venous) were collected for the analysis of pO2, pCO2 and pH. Morphological neurological outcome was evaluated by cranial ultrasound (cUS), whereas functional neurological outcome by Amiel-Tison Neurological Assessment at Term (ATNAT). 50 fetuses had C/U ratio>1, and 10 had C/U ratio≤1; among these 10 fetuses, 9 had abnormal neonatal cUS findings and all 10 had non-optimal ATNAT. However, the total number of abnormal neurological findings was much higher. 32 neonates had abnormal cUS (53.37%), and 42 (70.00%) had non-optimal ATNAT. Furthermore, Doppler indices had higher predictive validity for early brain disturbances than umbilical cord blood gases and pH. C/U ratio had the highest predictive validity with threshold for adverse neurological outcome at value 1.13 (ROC analysis), i.e., 1.18 (party machine learning algorithm). Adverse neurological outcome at average values of C/U ratios>1 confirmed that early functional and/or structural brain disturbances in late-onset IUGR develop even before activation of fetal cardiovascular compensatory mechanisms, i.e., before Doppler signs of blood flow redistribution between the fetal brain and the placenta. Copyright © 2015 Elsevier Ireland Ltd

  12. Arterial spin labelling reveals an abnormal cerebral perfusion pattern in Parkinson's disease.

    PubMed

    Melzer, Tracy R; Watts, Richard; MacAskill, Michael R; Pearson, John F; Rüeger, Sina; Pitcher, Toni L; Livingston, Leslie; Graham, Charlotte; Keenan, Ross; Shankaranarayanan, Ajit; Alsop, David C; Dalrymple-Alford, John C; Anderson, Tim J

    2011-03-01

    There is a need for objective imaging markers of Parkinson's disease status and progression. Positron emission tomography and single photon emission computed tomography studies have suggested patterns of abnormal cerebral perfusion in Parkinson's disease as potential functional biomarkers. This study aimed to identify an arterial spin labelling magnetic resonance-derived perfusion network as an accessible, non-invasive alternative. We used pseudo-continuous arterial spin labelling to measure cerebral grey matter perfusion in 61 subjects with Parkinson's disease with a range of motor and cognitive impairment, including patients with dementia and 29 age- and sex-matched controls. Principal component analysis was used to derive a Parkinson's disease-related perfusion network via logistic regression. Region of interest analysis of absolute perfusion values revealed that the Parkinson's disease pattern was characterized by decreased perfusion in posterior parieto-occipital cortex, precuneus and cuneus, and middle frontal gyri compared with healthy controls. Perfusion was preserved in globus pallidus, putamen, anterior cingulate and post- and pre-central gyri. Both motor and cognitive statuses were significant factors related to network score. A network approach, supported by arterial spin labelling-derived absolute perfusion values may provide a readily accessible neuroimaging method to characterize and track progression of both motor and cognitive status in Parkinson's disease.

  13. Cell-free fetal DNA concentration in plasma of patients with abnormal uterine artery Doppler waveform and intrauterine growth restriction--a pilot study.

    PubMed

    Caramelli, Elisabetta; Rizzo, Nicola; Concu, Manuela; Simonazzi, Giuliana; Carinci, Paolo; Bondavalli, Corrado; Bovicelli, Luciano; Farina, Antonio

    2003-05-01

    To evaluate if an increased amount of fetal DNA concentration can be found in women screened positive for intrauterine growth restriction because of abnormal uterine artery Doppler waveforms. We enrolled eight pregnant women (each bearing a male fetus), with the evidence of abnormal uterine artery Doppler waveforms, and 16 control patients for a case-control study matched for gestational age (1 : 2). Uterine artery Doppler was carried out at 20 to 35 weeks' gestation (median 29). The mean uterine artery resistance index (RI) was subsequently calculated, and a value >0.6 was considered positive for the clinical features of pre-eclampsia. The SRY locus was used to determine the amount of male fetal DNA in the maternal plasma at the time of Doppler analysis. Two controls (normal Doppler) were excluded from the final analysis because they had a pre-term delivery. One case (abnormal Doppler) had evidence of intrauterine growth restriction at the time of enrolment. In four out of eight cases (abnormal Doppler), intrauterine growth restriction was subsequently observed. Multiples of median (MoM) conversion of the fetal DNA values showed an increase of 1.81 times in the cases when compared to the controls. An increase of 2.16 times was instead observed for the cases with a growth-restricted fetus (5 cases out of 8) in comparison with the controls (14 cases). In subjects positive to uterine artery Doppler velocimetry analysis (Doppler analysis for pre-eclampsia screening), the fetal DNA concentration is higher than expected, in the absence of any other clinical feature. Since the increase in fetal DNA seems to be related to the presence or to the future development of intrauterine growth restriction, this paper suggests a possible integration between ultrasound and molecular markers for predicting the disease in some cases. Copyright 2003 John Wiley & Sons, Ltd.

  14. Umbilical Hernia

    MedlinePlus

    ... Prompt diagnosis and treatment can help prevent complications. Causes During pregnancy, the umbilical cord passes through a small opening ... abdominal pressure can cause an umbilical hernia. Possible causes in adults include: ... pregnancies Fluid in the abdominal cavity (ascites) Previous abdominal ...

  15. The agreement between abnormal venous lactate and arterial lactate in the ED: a retrospective chart review.

    PubMed

    Bloom, B; Pott, J; Freund, Y; Grundlingh, J; Harris, T

    2014-06-01

    The evidence for prognostication using lactate is often based on arterial lactate (AL). Arterial sampling is painful and difficult, and carries risks. Studies comparing peripheral venous lactate (PVL) with AL showed little difference but predominantly included patients with normal lactate. The objective of this study was to measure agreement between PVL and AL in patients with elevated venous lactate. This is a retrospective cross-sectional study. ED patients age≥16, attending from October 2010 to June 2011 inclusive, with PVL≥2.0 mmol/L and AL taken within 1 hour. intravenous fluid prior to or between initial venous and arterial sampling. Primary endpoint: agreement between PVL and AL defined as mean difference±95% limits of agreement (LOA). The misclassification rate was assessed. N=232. VL median 3.50 mmol/L, range 2.00 to 15.00 mmol/L. AL median 2.45 mmol/L, range 1.0 to 13.2 mmol/L. The mean difference±SD between PVL and AL for all patients was 1.06±1.30 mmol/L (95%LOA -1.53 to 3.66 mmol/L). Using a cut-off of 2 mmol/L and 4 mmol/L, 36.2% and 17.9% of patients respectively were incorrectly classified as having elevated lactate. We report greater bias between VL and AL with broader LOA than previously documented. This may partly be due to the fact that we studied only patients with abnormal venous values, for whom close agreement would confer greatest clinical significance. The agreement between abnormal PVL and AL is poor and the high rate of misclassification may suggest that PVL is not a good substitute for AL if the venous lactate is abnormal. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Umbilical venous-arterial plasma composition differences suggest differential incorporation of fatty acids in NEFA and cholesteryl ester pools.

    PubMed

    Lewis, Rohan M; Hanson, Mark A; Burdge, Graham C

    2011-08-01

    The developing fetus requires an adequate supply of fatty acids, in particular PUFA, for optimal growth and development. Little is known about the transfer of fatty acids by the placenta into the fetal circulation. However, the molecular form in which fatty acids are transferred into the fetal circulation may influence their metabolism and hence their availability to specific tissues. The aim of the present study was to determine which lipid pools in the fetal circulation become enriched in fatty acids from the placenta by comparing the fatty acid compositions of individual lipid pools between umbilical venous (UV) and umbilical arterial (UA) plasma. Plasma from the UV and UA was collected after delivery from ten uncomplicated pregnancies, and the fatty acid composition of each lipid class was determined by GC. Total NEFA concentration in the UV was twofold higher than in the UA (P < 0·05) due to enrichment in 16 : 0, 16 : 1n-7, 18 : 1n-9, 18 : 1n-7, 18 : 2n-6, 20 : 3n-6, 20 : 4n-6, 24 : 0 and 22 : 6n-3. Total cholesteryl ester concentration was twofold higher in the UV than in the UA (P < 0·05) due to enrichment in 16 : 0, 16 : 1n-7, 18 : 0, 18 : 1n-9, 18 : 1n-7, 18 : 2n-6 and 20 : 4n-6. There were no significant UV-UA differences in the total concentration or composition of TAG or phosphatidylcholine. The present study demonstrates differential enrichment across the placenta of fatty acids into specific lipid pools in the fetal circulation. Such partitioning may facilitate supply of individual fatty acids to specific fetal tissues.

  17. Congenital abnormalities associated with extrahepatic portal hypertension.

    PubMed Central

    Odièvre, M; Pigé, G; Alagille, D

    1977-01-01

    Congenital abnormalities were present in 12 out of 30 (40%) children with extrahepatic portal hypertension of unknown cause, but in only 2 out of 17 (12%) children with extnahepatic portal hypertension secondary to umbilical vein catheterization or omphalitis. The most frequent abnormalities in this series and in published reports were atrial septal defect, malformation of the biliary tract, and anomalous inferior vena cava. These findings are consistent with the view that some cases with extrahepatic portal hypertension are congenital in origin. PMID:869567

  18. Arterial stick

    MedlinePlus

    ... venous blood) mainly in its content of dissolved gases . Testing arterial blood shows the makeup of the ... arteries. Blood samples are mainly taken to measure gases in the arteries. Abnormal results may point to ...

  19. Umbilical hernia masking primary umbilical endometriosis - a case report.

    PubMed

    Brătilă, Elvira; Ionescu, Oana Maria; Badiu, Dumitru Cristinel; Berceanu, Costin; Vlădăreanu, Simona; Pop, Doina Mihaela; MehedinŢu, Claudia

    2016-01-01

    Endometriosis is a gynecologic condition affecting mainly the pelvic organs. However, extrapelvic endometriosis has been reported in almost all parts of the body. Umbilical endometriosis, either primary or secondary, is uncommon and has a documented neoplastic risk. We present the case of a 46-year-old woman with a large umbilical hernia associating primary umbilical endometriosis discovered during surgery and confirmed later by pathological and immunohistochemical exams. The patient underwent omphalectomy and partial omentum resection, alongside with mesh abdominal wall repair. The patient was informed about the recurrence risk and was asymptomatic at follow-up consults.

  20. Amnioinfusion for umbilical cord compression in labour.

    PubMed

    Hofmeyr, G J

    2000-01-01

    Amnioinfusion aims to prevent or relieve umbilical cord compression during labour by infusing a solution into the uterine cavity. The objective of this review was to assess the effects of amnioinfusion on maternal and perinatal outcome for potential or suspected umbilical cord compression or potential amnionitis. The Cochrane Pregnancy and Childbirth Group trials register and the Cochrane Controlled Trials Register were searched. Randomised trials of amnioinfusion compared with no amnioinfusion in women with babies at risk of umbilical cord compression; and women at risk of intrauterine infection. Eligibility and trial quality were assessed by the reviewer. Twelve studies were included. Transcervical amnioinfusion for potential or suspected umbilical cord compression was associated with the following reductions: fetal heart rate decelerations (relative risk 0.54, 95% confidence interval 0.43 to 0.68); caesarean section for suspected fetal distress (relative risk 0.35, 95% confidence interval 0.24 to 0.52); neonatal hospital stay greater than 3 days (relative risk 0.40, 95% confidence interval 0. 26 to 0.62); maternal hospital stay greater than 3 days (relative risk 0.46, 95% 0.29 to 0.74). Transabdominal amnioinfusion showed similar results. Transcervical amnioinfusion to prevent infection in women with membranes ruptured for more than 6 hours was associated with a reduction in puerperal infection (relative risk 0.50, 95% confidence interval 0.26 to 0.97). Amnioinfusion appears to reduce the occurrence of variable heart rate decelerations and lower the use of caesarean section. However the studies were done in settings where fetal distress was not confirmed by fetal blood sampling. The results may therefore only be relevant where caesarean sections are commonly done for abnormal fetal heart rate alone. The trials reviewed are too small to address the possibility of rare but serious maternal adverse effects of amnioinfusion.

  1. Amnioinfusion for potential or suspected umbilical cord compression in labour.

    PubMed

    Hofmeyr, G Justus; Lawrie, Theresa A

    2012-01-18

    Amnioinfusion aims to prevent or relieve umbilical cord compression during labour by infusing a solution into the uterine cavity. To assess the effects of amnioinfusion for potential or suspected umbilical cord compression on maternal and perinatal outcome . We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 October 2011). Randomised trials of amnioinfusion compared with no amnioinfusion in women with babies at risk of umbilical cord compression in labour. The original review had one author only (Justus Hofmeyr (GJH)). For this update, two authors (GJH and T Lawrie) assessed 13 additional trial reports for eligibility and quality. We extracted data and checked for accuracy. We have included 19 studies, with all but two studies having fewer than 200 participants. Transcervical amnioinfusion for potential or suspected umbilical cord compression was associated with the following reductions: caesarean section overall (13 trials, 1493 participants; average risk ratio (RR) 0.62, 95% confidence interval (CI) 0.46 to 0.83); fetal heart rate (FHR) decelerations (seven trials, 1006 participants; average RR 0.53, 95% CI 0.38 to 0.74); Apgar score less than seven at five minutes (12 trials, 1804 participants; average RR 0.47, 95% CI 0.30 to 0.72); meconium below the vocal cords (three trials, 674 participants, RR 0.53, 95% CI 0.31 to 0.92); postpartum endometritis (six trials, 767 participants; RR 0.45, 95% CI 0.25 to 0.81) and maternal hospital stay greater than three days (four trials, 1051 participants; average RR 0.45, 95% CI 0.25 to 0.78). Transabdominal amnioinfusion showed similar trends, though numbers studied were small.Mean cord umbilical artery pH was higher in the amnioinfusion group (seven trials, 855 participants; average mean difference 0.03, 95% CI 0.00 to 0.06) and there was a trend toward fewer neonates with a low cord arterial pH (less than 7.2 or as defined by trial authors) in the amnioinfusion group (eight trials, 972

  2. 46. BASE OF UMBILICAL MAST FROM UMBILICAL MAST TRENCH. ERECTION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    46. BASE OF UMBILICAL MAST FROM UMBILICAL MAST TRENCH. ERECTION AND RETRACTION CYLINDERS BETWEEN MAST AND TRENCH WALL. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  3. New technique for servo-control of arterial oxygen tension in preterm infants.

    PubMed Central

    Beddis, I R; Collins, P; Levy, N M; Godfrey, S; Silverman, M

    1979-01-01

    Equipment has been developed for the servo-control of arterial oxygen tension in sick, newborn babies. Using an indwelling umbilical arterial oxygen electrode as sensor, the equipment successfully regulated the administration of oxygen to 12 newborn babies with respiratory distress syndrome, significantly improving the stability of arterial oxygen tension and lessening the duration of episodes of hypoxia and hyperoxia. PMID:453911

  4. Umbilical hernia management during liver transplantation.

    PubMed

    de Goede, B; van Kempen, B J H; Polak, W G; de Knegt, R J; Schouten, J N L; Lange, J F; Tilanus, H W; Metselaar, H J; Kazemier, G

    2013-08-01

    Patients with liver cirrhosis scheduled for liver transplantation often present with a concurrent umbilical hernia. Optimal management of these patients is not clear. The objective of this study was to compare the outcomes of patients who underwent umbilical hernia correction during liver transplantation through a separate infra-umbilical incision with those who underwent correction through the same incision used to perform the liver transplantation. In the period between 1990 and 2011, all 27 patients with umbilical hernia and liver cirrhosis who underwent hernia correction during liver transplantation were identified in our hospital database. In 17 cases, umbilical hernia repair was performed through a separate infra-umbilical incision (separate incision group) and 10 were corrected from within the abdominal cavity without a separate incision (same incision group). Six patients died during follow-up; no deaths were attributable to intraoperative umbilical hernia repair. All 21 patients who were alive visited the outpatient clinic to detect recurrent umbilical hernia. One recurrent umbilical hernia was diagnosed in the separate incision group (6 %) and four (40 %) in the same incision group (p = 0.047). Two patients in the same incision group required repair of the recurrent umbilical hernia; one of whom underwent emergency surgery for bowel incarceration. The one recurrent hernia in the separate incision group was corrected electively. In the event of liver transplantation, umbilical hernia repair through a separate infra-umbilical incision is preferred over correction through the same incision used to perform the transplantation.

  5. Umbilical cord blood banking: implications for perinatal care providers.

    PubMed

    Armson, B Anthony

    2005-03-01

    -versus-host disease (GVHD) in both human leukocyte antigen(HLA)-matched and HLA-mismatched stem cell transplants, and ease of collection with little risk to the mother or newborn. Potential limitations of umbilical cord blood transplantation include insufficient stem cell dose to reliably treat larger children and adult recipients, slower rate of engraftment, and the potential for transfer of genetically abnormal hematopoietic stem cells. The optimum method of umbilical cord blood transplantation is not yet clear, though available evidence would favour collection before delivery of the placenta. There are many unresolved ethical issues related to umbilical cord blood banking, particularly related to the rapid growth of private, for-profit, cord blood banks offering long-term storage for potential future autologous or related allogenic transplantation. The financial burden to the health care system for public cord blood banking and to families for private cord blood collection and storage is considerable. 1. Perinatal care providers should be informed about the promising clinical potential of hematopoietic stem cells in umbilical cord blood and about current indications for its collection, storage, and use, based on sound scientific evidence (II-3B). 2. Umbilical cord blood collection should be considered for a sibling or parent in need of stem cell transplantation when an HLA-identical bone marrow cell or peripheral stem cell donation from a sibling or parent is unavailable for transplantation (II-2B). 3. Umbilical cord blood should be considered when allogeneic transplantation is the treatment of choice for a child who does not have an HLA-identical sibling or a well-matched, unrelated adult bone marrow donor (II-2B). 4. Umbilical cord blood should be considered for allogeneic transplantation in adolescents and young adults with hematologic malignancies who have no suitable bone marrow donor and who require urgent transplantation (II-3B). 5. Altruistic donation of cord blood for

  6. Ultrasound predictors of mortality in monochorionic twins with selective intrauterine growth restriction.

    PubMed

    Ishii, K; Murakoshi, T; Hayashi, S; Saito, M; Sago, H; Takahashi, Y; Sumie, M; Nakata, M; Matsushita, M; Shinno, T; Naruse, H; Torii, Y

    2011-01-01

    The aim of this study was to evaluate the use of ultrasound assessment to predict risk of mortality in expectantly managed monochorionic twin fetuses with selective intrauterine growth restriction (sIUGR). This was a retrospective study of 101 monochorionic twin pregnancies diagnosed with sIUGR before 26 weeks of gestation. All patients were under expectant management during the observation period. At the initial evaluation, the presence or absence of each of the following abnormalities was documented: oligohydramnios; stuck twin phenomenon; severe IUGR < 3(rd) centile of estimated fetal weight; abnormal Doppler in the umbilical artery; and polyhydramnios in the larger twin. The relationships between these ultrasound findings and mortality of sIUGR fetuses were evaluated using multiple logistic regression analysis. Of 101 sIUGR twins, 22 (21.8%) fetuses suffered intrauterine demise and nine (8.9%) suffered neonatal death; 70 (69.3%) survived the neonatal period. Multiple logistic regression analysis revealed that the stuck twin phenomenon (odds ratio (OR): 14.5; 95% CI: 2.2-93.2; P = 0.006) and constantly absent diastolic flow in the umbilical artery (OR: 29.4; 95% CI: 3.3-264.0; P = 0.003) were significant risk factors for mortality. Not only abnormal Doppler flow in the umbilical artery but also severe oligohydramnios should be recognized as important indicators for mortality in monochorionic twins with sIUGR.

  7. Introducing a Mobile-Connected Umbilical Doppler Device (UmbiFlow™) into a Primary Care Maternity Setting: Does This Reduce Unnecessary Referrals to Specialised Care? Results of a Pilot Study in Kraaifontein, South Africa.

    PubMed

    Mufenda, Josef; Gebhardt, Stefan; van Rooyen, Rita; Theron, Gerhard

    2015-01-01

    UmbiFlow™ is a mobile-connected Doppler device that utilises a continuous waveform to measure resistance in the umbilical artery. The main aim of this pilot study was to determine whether the use of UmbiFlow™ for umbilical artery Doppler in patients with a suspected decreased symphysis fundal (SF) growth could safely lead to a decreased number of patients requiring referral to a more specialised level of care. A secondary aim of the study was to evaluate the effectiveness of UmbiFlow™ Doppler as a screening tool for concealed placental insufficiency in late bookers by using a single screening cut-off value that will be abnormal for any gestation >28 weeks. The cohort comprised two groups of patients: The first group included all follow-up patients with suspected intra-uterine growth restriction (a decreased symphysis-fundus measurement based on serial assessment) who underwent on-site UmbiFlow™Doppler testing performed by the midwife directly after the clinical examination. The second group included late bookers, where gestation was uncertain; but estimated >28 weeks based on clinical grounds. This group was comprised of unselected patients who report to antenatal care late for the first time and received an UmbiFlow™Doppler test for concealed placental insufficiency. UmbiFlow™Doppler could reduce the number of false referrals to hospital by 55%. A single UmbiFlow™Doppler test in late bookers appeared to identify a group of women at moderate risk of lower birth weight babies.

  8. Umbilical paracentesis for incarcerated umbilical hernia in patients with end-stage liver disease.

    PubMed

    Alonso, S; Donat, M; Carrion, L; Rodriguez, J M; Diego, L; Acin, D; Serrano, A; Perez, E; Pereira, F

    2016-08-01

    Patients with cirrhosis and ascites are prone to abdominal wall complications largely predominate by umbilical hernia. Elective surgery is indicated in select patients but a high morbidity and mortality rate occurs if it is performed in emergency conditions. We present a clinical case of a patient with advanced alcoholic liver disease who came to the emergency room for an acutely incarcerated umbilical hernia. Due to the high surgical risk, we had to discuss other treatment options. The use of umbilical paracentesis for incarcerated hernia reduction in cirrhotic patients with tense ascites is a safe and reproducible technique. Umbilical paracentesis could be considered as an alternative to emergency surgery in these high-risk patients.

  9. Poland syndrome associated with an aberrant subclavian artery and vascular abnormalities of the retina in a child exposed to misoprostol during pregnancy.

    PubMed

    Rosa, Rafael Fabiano Machado; Travi, Giovanni M; Valiatti, Fabiana; Zen, Paulo Ricardo Gazzola; Pinto, Louise Lapagesse; Kiss, Andrea; Graziadio, Carla; Paskulin, Giorgio Adriano

    2007-06-01

    Poland syndrome has been attributed to a process of vascular disruption, and exposure to misoprostol at 6-8 weeks of gestation has been shown to produce defects attributed to vascular disruption. Herein we report the first case of a patient with Poland syndrome associated with an aberrant subclavian artery and vascular abnormalities of the retina, whose mother used misoprostol during pregnancy. A White boy of 1 year and 7 months of age, whose mother used misoprostol during the second month of pregnancy, presented with bilateral epicanthal folds, aplasia of the sternocostal head of the pectoralis major muscle with a hypoplastic nipple on the right side, and asymmetry between the upper limbs. The results of an angiotomographic study showed the presence of an aberrant right subclavian artery. Ultrasonographic evaluation showed turbulence and a high peak in the diastolic velocity in both carotid arteries, suggesting stenosis. Ophthalmologic assessment disclosed an intense bilateral tortuosity of the retinal blood vessels, with arterialnarrowing and rarefaction of the retinal pigment epithelium. This case suggests that the mechanism of vascular disruption of misoprostol could be related to the aberrant subclavian artery and the observed Poland syndrome. His retinal findings are different from those in cases described thus far in the literature, and this pattern of anomaly has never been associated with a gestational exposure to misoprostol. The possibility of a relationship of the aberrant right subclavian artery and the pattern of blood flow verified in the carotid arteries with the eye fundus abnormalities could be causally related or simply coincidental.

  10. The best option: Umbilical LESS radical nephrectomy with vaginal extraction.

    PubMed

    Andrés, G; García-Mediero, J M; García-Tello, A; Arance, I; Cabrera, P M; Angulo, J C

    2015-04-01

    Umbilical laparoendoscopic single-site (LESS) surgery represents an excellent alternative to laparoscopic or robotic multiport surgery. LESS surgery offers faster recovery, less postoperative pain and optimal cosmetic results. The reusable nature of its instruments also has significant economic advantages. We present a 34-year-old patient with a solid mesorenal lesion measuring 8 cm in the left kidney treated with pure LESS radical nephrectomy assisted by vaginal extraction of the specimen. The umbilical approach using a single-site multichannel KeyPort (Richard Wolf GmbH, Knittlingen, Germany) with DuoRotate curved instruments allows for minimum crushing and fewer spatial conflicts. Its perfect umbilical adaptation provides a hermetic system. The instrument's double rotation provides considerable movement precision. Vaginal extraction avoids damage to the abdominal wall and the need for widening the umbilical incision. After the placement of the device and triangulation of the clips, we proceeded to operate on posterior parietal peritoneum. The descending colon was mobilized to access the retroperitoneum and dissect the renal hilum. Hem-o-lok clips were placed on the artery and vein, which were subsequently sectioned. The specimen was inserted into a laparoscopic bag. Under direct vision, we placed a 15-mm trocar through the bottom of the vaginal posterior fornix to facilitate the extraction of the bag's thread. The incision was widened with the fingers, and the specimen was extracted, closing the vagina from the perineum with visualization from the navel. Abdominal drainage was not employed. The surgical time was 180 min. The patient was discharged the following day without needing analgesia. A year later, the patient was disease-free and had no complications. Umbilical LESS radical nephrectomy with vaginal extraction is feasible in selected cases. The procedure is oncologically safe, avoids scars and facilitates early recovery. From a practical point of view

  11. Risk of fetal death in growth-restricted fetuses with umbilical and/or ductus venosus absent or reversed end-diastolic velocities before 34 weeks of gestation: a systematic review and meta-analysis.

    PubMed

    Caradeux, J; Martinez-Portilla, R J; Basuki, T R; Kiserud, T; Figueras, F

    2018-02-01

    The objective of the study was to establish the risk of fetal death in early-onset growth-restricted fetuses with absent or reversed end-diastolic velocities in the umbilical artery or ductus venosus. A systematic search was performed to identify relevant studies published in English, Spanish, French, Italian, or German using the databases PubMed, ISI Web of Science, and SCOPUS, without publication time restrictions. The study criteria included observational cohort studies and randomized controlled trials of early-onset growth-restricted fetuses (diagnosed before 34 weeks of gestation), with information on the rate of fetal death occurring before 34 weeks of gestation and absent or reversed end-diastolic velocities in the umbilical artery and/or ductus venosus. For quality assessment, 2 reviewers independently assessed the risk of bias using the Newcastle-Ottawa Scale for observational studies and the Cochrane Collaboration's tool for randomized trials. For the meta-analysis, odds ratio for both fixed and random-effects models (weighting by inverse of variance) were used. Heterogeneity between studies was assessed using tau 2 , χ2 (Cochrane Q), and I 2 statistics. Publication bias was assessed by a funnel plot for meta-analyses and quantified by the Egger method. A total of 31 studies were included in this meta-analysis. The odds ratios for fetal death (random-effects models) were 3.59 (95% confidence interval, 2.3-5.6), 7.27 (95% confidence interval, 4.6-11.4), and 11.6 (95% confidence interval, 6.3-19.7) for growth-restricted fetuses with umbilical artery absent end-diastolic velocities, umbilical artery reversed end-diastolic velocities, and ductus venosus absent or reversed end-diastolic velocities, respectively. There was no substantial heterogeneity among studies for any of the analyses. Early-onset growth-restricted fetuses with either umbilical artery or ductus venosus absent or reserved end-diastolic velocities are at a substantially increased risk for

  12. Large Scale Expansion of Human Umbilical Cord Cells in a Rotating Bed System Bioreactor for Cardiovascular Tissue Engineering Applications

    PubMed Central

    Reichardt, Anne; Polchow, Bianca; Shakibaei, Mehdi; Henrich, Wolfgang; Hetzer, Roland; Lueders, Cora

    2013-01-01

    Widespread use of human umbilical cord cells for cardiovascular tissue engineering requires production of large numbers of well-characterized cells under controlled conditions. In current research projects, the expansion of cells to be used to create a tissue construct is usually performed in static cell culture systems which are, however, often not satisfactory due to limitations in nutrient and oxygen supply. To overcome these limitations dynamic cell expansion in bioreactor systems under controllable conditions could be an important tool providing continuous perfusion for the generation of large numbers of viable pre-conditioned cells in a short time period. For this purpose cells derived from human umbilical cord arteries were expanded in a rotating bed system bioreactor for up to 9 days. For a comparative study, cells were cultivated under static conditions in standard culture devices. Our results demonstrated that the microenvironment in the perfusion bioreactor was more favorable than that of the standard cell culture flasks. Data suggested that cells in the bioreactor expanded 39 fold (38.7 ± 6.1 fold) in comparison to statically cultured cells (31.8 ± 3.0 fold). Large-scale production of cells in the bioreactor resulted in more than 3 x 108 cells from a single umbilical cord fragment within 9 days. Furthermore cell doubling time was lower in the bioreactor system and production of extracellular matrix components was higher. With this study, we present an appropriate method to expand human umbilical cord artery derived cells with high cellular proliferation rates in a well-defined bioreactor system under GMP conditions. PMID:23847691

  13. Automated Ground Umbilical Systems (AGUS) Project

    NASA Technical Reports Server (NTRS)

    Gosselin, Armand M.

    2007-01-01

    All space vehicles require ground umbilical systems for servicing. Servicing requirements can include, but are not limited to, electrical power and control, propellant loading and venting, pneumatic system supply, hazard gas detection and purging as well as systems checkout capabilities. Of the various types of umbilicals, all require several common subsystems. These typically include an alignment system, mating and locking system, fluid connectors, electrical connectors and control !checkout systems. These systems have been designed to various levels of detail based on the needs for manual and/or automation requirements. The Automated Ground Umbilical Systems (AGUS) project is a multi-phase initiative to develop design performance requirements and concepts for launch system umbilicals. The automation aspect minimizes operational time and labor in ground umbilical processing while maintaining reliability. This current phase of the project reviews the design, development, testing and operations of ground umbilicals built for the Saturn, Shuttle, X-33 and Atlas V programs. Based on the design and operations lessons learned from these systems, umbilicals can be optimized for specific applications. The product of this study is a document containing details of existing systems and requirements for future automated umbilical systems with emphasis on design-for-operations (DFO).

  14. Umbilical Cord Blood: Counselling, Collection, and Banking.

    PubMed

    Armson, B Anthony; Allan, David S; Casper, Robert F

    2015-09-01

    bone marrow or peripheral stem cell transplantation to treat malignant and non-malignant conditions in children and adults. There is minimal harm to the mother or newborn provided that priority is given to maternal/newborn safety during childbirth management. Recipients of umbilical cord stem cells may experience graft-versus-host disease, transfer of infection or genetic abnormalities, or therapeutic failure. The financial burden on the health system for public cord blood banking and on families for private cord blood banking is considerable. Recommendations 1. Health care professionals should be well-informed about cord blood collection and storage and about factors that influence the volume, quality, and ability to collect a cord blood unit. (III-A) 2. Health care professionals caring for women and families who choose private umbilical cord blood banking must disclose any financial interests or potential conflicts of interest. (III-A) 3. Pregnant women should be provided with unbiased information about umbilical cord blood banking options, including the benefits and limitations of public and private banks. (III-A) 4. Health care professionals should obtain consent from mothers for the collection of umbilical cord blood prior to the onset of active labour, ideally during the third trimester, with ample time to address any questions. (III-A) 5. Health care professionals must be trained in standardized procedures (ex utero and in utero techniques) for cord blood collection to ensure the sterility and quality of the collected unit. (II-2A) 6. Umbilical cord blood should be collected with the goal of maximizing the content of hematopoietic progenitors through the volume collected. The decision to bank the unit will depend upon specific measures of graft potency. (II-2A) 7. Umbilical cord blood collection must not adversely affect the health of the mother or newborn. Cord blood collection should not interfere with delayed cord clamping. (III-E) 8. Health care

  15. Influence of elastin-derived peptides, glucose, LDL and oxLDL on nitric oxide synthase expression in human umbilical artery endothelial cells.

    PubMed

    Garczorz, Wojciech; Francuz, Tomasz; Gmiński, Jan; Likus, Wirginia; Siemianowicz, Krzysztof; Jurczak, Teresa; Strzałka-Mrozik, Barbara

    2011-01-01

    Endothelial dysfunction plays an important role in the development of atherosclerosis. Elastin-derived peptides (EDP), hyperglycemia, hypercholesterolemia and oxidized LDL have a proven proatherosclerotic potential. Nitric oxide generated by endothelial nitric oxide synthase (eNOS; EC 1.14.13.39) is an important vasorelaxant. Here we studied the influence of those proatherosclerotic factors on eNOS gene and protein expression in artery-derived endothelial cells. Human umbilical artery endothelial cells (HUAEC) were incubated with or without: glucose (270 mg/dl), LDL (200 mg/dl), oxidized LDL (oxLDL 25 mg/dl) or κ-elastin (0.5 and 2.5 µg/ml). Gene expression was assessed by real time RT-PCR, whilst the eNOS protein by ELISA. In cells incubated with 2.5 µg/ml of κ-elastin, a 31 % increase of eNOS mRNA expression was observed, but the protein level remained unchanged. OxLDL, LDL and glucose decreased the eNOS protein level by 74 %, 37 % and 29 %, respectively. OxLDL decreased eNOS mRNA by 42 %. LDL non-significantly decreased eNOS mRNA expression. An elevated glucose level did not affect the eNOS mRNA expression. Hyperglycemia and an elevated level of LDL, particularly oxLDL, decreased the level of eNOS protein in endothelial cells. As κ-elastin did not decrease the expression of eNOS gene in HUAEC, the proatherogenic properties of elastin-derived peptides are unlikely to be due to their influence on eNOS.

  16. Umbilical Arterial Blood Sampling Alters Cerebral Tissue Oxygenation in Very Low Birth Weight Neonates.

    PubMed

    Mintzer, Jonathan P; Parvez, Boriana; La Gamma, Edmund F

    2015-11-01

    To evaluate the magnitude, consistency, and natural history of reductions in cerebral regional tissue oxygenation (CrSO2) during umbilical arterial (UA) blood sampling in very low birth weight neonates. Data were collected during a prospective observational near-infrared spectroscopy survey conducted on a convenience sample of 500-1250 g neonates during the first 10 postnatal days. A before-after analysis of UA blood sampling effects on CrSO2 absolute values and variability was performed. The present analysis was not designed a priori and was conducted following the bedside observation of CrSO2 decrements contiguous with UA blood draws. Fifteen very low birth weight neonates had 201 UA blood draws. Baseline CrSO2 (mean ± SEM) decreased following UA blood sampling, from 70 ± 1% to a nadir of 63 ± 1% (P < .001) occurring 4 ± 3 (range 2-24) minutes following blood draws. CrSO2 subsequently increased to 70 ± 1% (P < .001 compared with nadir) at 10 ± 4 (range 4-28) minutes following UA blood sampling. Coefficients of variation (mean ± SEM) increased from 0.02 ± 0.001 at baseline to 0.05 ± 0.004 (P < .001), followed by a decrease to 0.03 ± 0.003 (P < .001 for all comparisons), thus denoting increased CrSO2 variability following UA blood sampling. UA blood sampling is associated with significant CrSO2 decrements with increased variability over clinically significant intervals. Whether these changes impact complications of prematurity, including intraventricular hemorrhage and periventricular leukomalacia, remain unknown. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Up-regulation of the mammalian target of rapamycin complex 1 subunit Raptor by aldosterone induces abnormal pulmonary artery smooth muscle cell survival patterns to promote pulmonary arterial hypertension

    PubMed Central

    Aghamohammadzadeh, Reza; Zhang, Ying-Yi; Stephens, Thomas E.; Arons, Elena; Zaman, Paula; Polach, Kevin J.; Matar, Majed; Yung, Lai-Ming; Yu, Paul B.; Bowman, Frederick P.; Opotowsky, Alexander R.; Waxman, Aaron B.; Loscalzo, Joseph; Leopold, Jane A.; Maron, Bradley A.

    2016-01-01

    Activation of the mammalian target of rapamycin complex 1 (mTORC1) subunit Raptor induces cell growth and is a downstream target of Akt. Elevated levels of aldosterone activate Akt, and, in pulmonary arterial hypertension (PAH), correlate with pulmonary arteriole thickening, which suggests that mTORC1 regulation by aldosterone may mediate adverse pulmonary vascular remodeling. We hypothesized that aldosterone-Raptor signaling induces abnormal pulmonary artery smooth muscle cell (PASMC) survival patterns to promote PAH. Remodeled pulmonary arterioles from SU-5416/hypoxia-PAH rats and monocrotaline-PAH rats with hyperaldosteronism expressed increased levels of the Raptor target, p70S6K, which provided a basis for investigating aldosterone-Raptor signaling in human PASMCs. Aldosterone (10−9 to 10−7 M) increased Akt/mTOR/Raptor to activate p70S6K and increase proliferation, viability, and apoptosis resistance in PASMCs. In PASMCs transfected with Raptor–small interfering RNA or treated with spironolactone/eplerenone, aldosterone or pulmonary arterial plasma from patients with PAH failed to increase p70S6K activation or to induce cell survival in vitro. Optimal inhibition of pulmonary arteriole Raptor was achieved by treatment with Staramine-monomethoxy polyethylene glycol that was formulated with Raptor-small interfering RNA plus spironolactone in vivo, which decreased arteriole muscularization and pulmonary hypertension in 2 experimental animal models of PAH in vivo. Up-regulation of mTORC1 by aldosterone is a critical pathobiologic mechanism that controls PASMC survival to promote hypertrophic vascular remodeling and PAH.—Aghamohammadzadeh, R., Zhang, Y.-Y., Stephens, T. E., Arons, E., Zaman, P., Polach, K. J., Matar, M., Yung, L.-M., Yu, P. B., Bowman, F. P., Opotowsky, A. R., Waxman, A. B., Loscalzo, J., Leopold, J. A., Maron, B. A. Up-regulation of the mammalian target of rapamycin complex 1 subunit Raptor by aldosterone induces abnormal pulmonary artery

  18. Up-regulation of the mammalian target of rapamycin complex 1 subunit Raptor by aldosterone induces abnormal pulmonary artery smooth muscle cell survival patterns to promote pulmonary arterial hypertension.

    PubMed

    Aghamohammadzadeh, Reza; Zhang, Ying-Yi; Stephens, Thomas E; Arons, Elena; Zaman, Paula; Polach, Kevin J; Matar, Majed; Yung, Lai-Ming; Yu, Paul B; Bowman, Frederick P; Opotowsky, Alexander R; Waxman, Aaron B; Loscalzo, Joseph; Leopold, Jane A; Maron, Bradley A

    2016-07-01

    Activation of the mammalian target of rapamycin complex 1 (mTORC1) subunit Raptor induces cell growth and is a downstream target of Akt. Elevated levels of aldosterone activate Akt, and, in pulmonary arterial hypertension (PAH), correlate with pulmonary arteriole thickening, which suggests that mTORC1 regulation by aldosterone may mediate adverse pulmonary vascular remodeling. We hypothesized that aldosterone-Raptor signaling induces abnormal pulmonary artery smooth muscle cell (PASMC) survival patterns to promote PAH. Remodeled pulmonary arterioles from SU-5416/hypoxia-PAH rats and monocrotaline-PAH rats with hyperaldosteronism expressed increased levels of the Raptor target, p70S6K, which provided a basis for investigating aldosterone-Raptor signaling in human PASMCs. Aldosterone (10(-9) to 10(-7) M) increased Akt/mTOR/Raptor to activate p70S6K and increase proliferation, viability, and apoptosis resistance in PASMCs. In PASMCs transfected with Raptor-small interfering RNA or treated with spironolactone/eplerenone, aldosterone or pulmonary arterial plasma from patients with PAH failed to increase p70S6K activation or to induce cell survival in vitro Optimal inhibition of pulmonary arteriole Raptor was achieved by treatment with Staramine-monomethoxy polyethylene glycol that was formulated with Raptor-small interfering RNA plus spironolactone in vivo, which decreased arteriole muscularization and pulmonary hypertension in 2 experimental animal models of PAH in vivo Up-regulation of mTORC1 by aldosterone is a critical pathobiologic mechanism that controls PASMC survival to promote hypertrophic vascular remodeling and PAH.-Aghamohammadzadeh, R., Zhang, Y.-Y., Stephens, T. E., Arons, E., Zaman, P., Polach, K. J., Matar, M., Yung, L.-M., Yu, P. B., Bowman, F. P., Opotowsky, A. R., Waxman, A. B., Loscalzo, J., Leopold, J. A., Maron, B. A. Up-regulation of the mammalian target of rapamycin complex 1 subunit Raptor by aldosterone induces abnormal pulmonary artery smooth

  19. Spacecraft automatic umbilical system

    NASA Technical Reports Server (NTRS)

    Goldin, R. W.; Jacquemin, G. G.; Johnson, W. H.

    1981-01-01

    An umbilical system design is described that incorporates all the features specified for a power system to payload interconnect capability. A proof-of-concept prototype of the umbilical system was built to determine experimentally the suitability of the threading characteristics of the ram mechanism and to verify freedom from cross threading. It is concluded that Berthing systems that utilize remote manipulator systems (RMS) can be simplified by using RMS targets, closed circuit TV cameras, tie into the RMS control system, and grapple-fixture and end-effector-like capture and secure mechanisms. To effect a remotely controlled umbilical interconnect in proximity with a manned spacecraft and to provide for extravehicular activity backup and maintenance capabilities, 18 different mechanisms are found to be necessary. The weight impact of proving for maintenance capability in a large multiple connector umbilical system was found to be in the order of +60 percent.

  20. Arterial and venous endothelia display differential functional fractalkine (CX3CL1) expression by angiotensin-II.

    PubMed

    Rius, Cristina; Piqueras, Laura; González-Navarro, Herminia; Albertos, Fernando; Company, Chantal; López-Ginés, Concha; Ludwig, Andreas; Blanes, Jose-Ignacio; Morcillo, Esteban J; Sanz, Maria-Jesus

    2013-01-01

    Angiotensin-II (Ang-II) promotes the interaction of mononuclear cells with arterioles and neutrophils with postcapillary venules. To investigate the mechanisms underlying this dissimilar response, the involvement of fractalkine (CX(3)CL1) was explored. Enhanced CX(3)CL1 expression was detected in both cremasteric arterioles and postcapillary venules 24 hours after Ang-II intrascrotal injection. Arteriolar leukocyte adhesion was the unique parameter significantly reduced (83%) in animals lacking CX(3)CL1 receptor (CX(3)CR1). Human umbilical arterial and venous endothelial cell stimulation with 1 μmol/L Ang-II increased CX(3)CL1 expression, yet neutralization of CX(3)CL1 activity only significantly inhibited Ang-II-induced mononuclear cell-human umbilical arterial endothelial cell interactions (73%) but not with human umbilical venous endothelial cells. The use of small interfering RNA revealed the involvement of tumor necrosis factor-α in Ang-II-induced CX(3)CL1 upregulation and mononuclear cell arrest. Nox5 knockdown with small interfering RNA or pharmacological inhibition of extracellular signal-regulated kinases1/2, p38 mitogen-activated protein kinase, and nuclear factor-κB also abolished these responses. Finally, when human umbilical arterial endothelial cells were costimulated with Ang-II, tumor necrosis factor-α, and interferon-γ, CX(3)CL1 expression and mononuclear cell adhesiveness were more pronounced than when each stimulus was provided alone. These results suggest that Ang-II induces functional CX(3)CL1 expression in arterial but not in venous endothelia. Thus, targeting endothelial CX(3)CL1-mononuclear leukocyte CX(3)CR1 interactions may constitute a new therapeutic strategy in the treatment of Ang-II-associated cardiovascular diseases.

  1. Biological behaviour of human umbilical artery smooth muscle cell grown on nickel-free and nickel-containing stainless steel for stent implantation

    PubMed Central

    Li, Liming; An, Liwen; Zhou, Xiaohang; Pan, Shuang; Meng, Xin; Ren, Yibin; Yang, Ke; Guan, Yifu

    2016-01-01

    To evaluate the clinical potential of high nitrogen nickel-free austenitic stainless steel (HNNF SS), we have compared the cellular and molecular responses of human umbilical artery smooth muscle cells (HUASMCs) to HNNF SS and 316L SS (nickel-containing austenitic 316L stainless steel). CCK-8 analysis and flow cytometric analysis were used to assess the cellular responses (proliferation, apoptosis, and cell cycle), and quantitative real-time PCR (qRT-PCR) was used to analyze the gene expression profiles of HUASMCs exposed to HNNF SS and 316L SS, respectively. CCK-8 analysis demonstrated that HUASMCs cultured on HNNF SS proliferated more slowly than those on 316L SS. Flow cytometric analysis revealed that HNNF SS could activate more cellular apoptosis. The qRT-PCR results showed that the genes regulating cell apoptosis and autophagy were up-regulated on HNNF SS. Thus, HNNF SS could reduce the HUASMC proliferation in comparison to 316L SS. The findings furnish valuable information for developing new biomedical materials for stent implantation. PMID:26727026

  2. Biological behaviour of human umbilical artery smooth muscle cell grown on nickel-free and nickel-containing stainless steel for stent implantation

    NASA Astrophysics Data System (ADS)

    Li, Liming; An, Liwen; Zhou, Xiaohang; Pan, Shuang; Meng, Xin; Ren, Yibin; Yang, Ke; Guan, Yifu

    2016-01-01

    To evaluate the clinical potential of high nitrogen nickel-free austenitic stainless steel (HNNF SS), we have compared the cellular and molecular responses of human umbilical artery smooth muscle cells (HUASMCs) to HNNF SS and 316L SS (nickel-containing austenitic 316L stainless steel). CCK-8 analysis and flow cytometric analysis were used to assess the cellular responses (proliferation, apoptosis, and cell cycle), and quantitative real-time PCR (qRT-PCR) was used to analyze the gene expression profiles of HUASMCs exposed to HNNF SS and 316L SS, respectively. CCK-8 analysis demonstrated that HUASMCs cultured on HNNF SS proliferated more slowly than those on 316L SS. Flow cytometric analysis revealed that HNNF SS could activate more cellular apoptosis. The qRT-PCR results showed that the genes regulating cell apoptosis and autophagy were up-regulated on HNNF SS. Thus, HNNF SS could reduce the HUASMC proliferation in comparison to 316L SS. The findings furnish valuable information for developing new biomedical materials for stent implantation.

  3. Umbilical scarring in hatchling American alligators

    USGS Publications Warehouse

    Wiebe, J.J.; Sepulveda, M.S.; Buckland, J.E.; Anderson, S.R.; Gross, T.S.

    2004-01-01

    Umbilical scarring is the presence of excess scar tissue deposited between abdominal dermal layers at the site of yolk sac absorption in hatchling American alligators (Alligator mississippiensis). The presence of this dermal condition plays a key evaluatory role in the overall quality and subsequent value for various commercial leather products. Despite the prevalent nature of this condition, currently the industry has no standardized protocols for its quantification. The objectives of this study were to examine the relationship between hatchling weight and age and incidence of umbilical scarring and to develop a quantifiable and reproducible technique to measure this dermal condition in hatchling American alligators. Thirty eggs from each of nine clutches were incubated in two separate incubators at different facilities and hatchling umbilical scarring was measured at 2 and 10 days of age using digital calipers. Umbilical area was calculated by multiplying umbilical length times umbilical width. There was a significant effect of both age and clutch on umbilical area (overall decline of 64%) by 10 days post-hatch. However, only five of the nine clutches utilized expressed a noticeable decline in the size of this dermal condition (range 67-74%). We had hypothesized that larger hatchlings would have larger umbilical areas and a slower rate of improvement in this condition during the first few days post-hatch. The differences in umbilical area and percent decline with age across clutches, however, were not associated with differences in initial hatchling weights. Within clutches and time periods, hatchling weight had no significant effect on the size and/or rate of decline of this condition. ?? 2004 Published by Elsevier B.V.

  4. Incarcerated umbilical hernia in children.

    PubMed

    Chirdan, L B; Uba, A F; Kidmas, A T

    2006-02-01

    Umbilical hernia is common in children. Complications from umbilical hernias are thought to be rare and the natural history is spontaneous closure within 5 years. A retrospective analysis was performed of the medical records of a series of 23 children who presented with incarcerated umbilical hernias at our institution over an 8-year period. Fifty-two children with umbilical hernias were seen in the hospital over the period. Twenty-three (44.2%) had incarceration. Seventeen (32.7%) had acute incarceration while 6 (11.5%) had recurrent incarceration. There were 16 girls and 7 boys. The ages of the children with acute incarceration ranged from 3 weeks to 12 years (median 4 years), while the ages of those with recurrent incarceration ranged from 3-15 years (median 8.5 years). Incarceration occurred in hernias of more than 1.5 cm in diameter (in those whose defect size was measured). Twenty-one children (15 with acute and all six with recurrent incarceration) underwent repair of the umbilical hernia using standard methods. The parents of two children with acute incarceration declined surgery after spontaneous reduction of the hernia in one and taxis in the other. One boy had gangrenous bowel containing Meckel's diverticulum inside the sac, for which bowel resection with end-to-end anastomosis was done. Operation led to disappearance of pain in all 6 children with recurrent incarceration. Superficial wound infection occurred in one child. There was no mortality. Incarcerated umbilical hernia is not as uncommon as thought. Active observation of children with umbilical hernia is necessary to prevent morbidity from incarceration.

  5. Coronary Artery Bypass Grafting for an Anomalous Left Coronary Artery from the Pulmonary Artery in a 73-Year-Old Female.

    PubMed

    Ishida, Narihiro; Shimabukuro, Katsuya; Ogura, Hiroki; Takemura, Hirofumi; Doi, Kiyoshi

    2016-06-01

    Anomalous left coronary artery from the pulmonary artery (ALCAPA) in adults is a rare congenital coronary abnormality. We report a case of ALCAPA in a 73-year-old female managed by total arterial revascularization. doi: 10.1111/jocs.12755 (J Card Surg 2016;31:380-382). © 2016 Wiley Periodicals, Inc.

  6. Isolated anomalous origin of the vertebral artery from the common carotid artery.

    PubMed

    Kesler, William W; Sabat, Shyamsunder B

    2018-04-18

    Anomalous origins of the vertebral arteries are uncommon and typically associated with other abnormalities of the great vessels. We present a case of an isolated origin of the right vertebral artery from the ipsilateral common carotid artery detected using magnetic resonance angiography. Such variants can significantly affect endovascular and surgical planning.

  7. Umbilical cord care in newborns

    MedlinePlus

    ... the stump clean with gauze and water only. Sponge bathe the rest of your baby, as well. ... Neonatal care - umbilical cord Images Umbilical cord healing Sponge bath References Carlo WA, Ambalavanan N. The umbilicus. ...

  8. [Measurement of umbilical activin A level in preterm infants].

    PubMed

    Zhong, Ying; Li, Juan; Wei, Ke-Lun

    2011-10-01

    To evaluate the clinical significance of umbilical activin A in preterm infants. Forty-one preterm infants (gestation 28 to 36 weeks) were enrolled. Fetal membranes, umbilical cords and blood samples from umbilical vein were obtained. Umbilical activin A level was measured using ELISA. The histological examinations of fetal membranes and umbilical cords were performed. The umbilical level of activin A averaged 2069 pg/mL in the 41 preterm infants. The umbilical activin A level in the 5 infants with intrauterine infection was higher than in those without intrauterine infection (2510 pg/mL vs 1975 pg/mL; P<0.01). Umbilical activin A level at cutoff of 2490 pg/mL showed a sensitivity of 80.0% and a specificity of 90.6% as a marker of intrauterine infection. There were no significant differences in the umbilical activin A level between the infants with and without respiratory distress syndrome. Umbilical activin A level was positively correlated with the duration of postnatal oxygen therapy (r=0.326, P<0.05). Umbilical activin A may serve a marker of intrauterine infection in preterm infants. The umbilical activin A level is correlated with the duration of postnatal oxygen therapy.

  9. [Intestinal polyp of the umbilical cord].

    PubMed

    Guschmann, M; Janda, J; Wenzelides, K; Vogel, M

    2002-02-01

    The morphology, pathogenesis, complications and differential diagnosis of an intestinal polyp of the umbilical cord are presented. The polyp were detected postnatal on the umbilical cord in an healthy male newborn. The presents of intestinal tissue upon the umbilical cord ist possible about the persistence from remnants of the ductus omphalomesentericus with prolapse and differentiation of the intestinal cells. The ductus omphalomesentericus is a tubular structure, a communication between the developing embryonic gut and the yolk sac, forming during the early embryonic life. Obliteration of the omphalomesenteric duct is usually complete by the 10(th) week of gestation. Various portions of the duct may persist, however, giving rise to polyps, fistulas or cysts of the umbilical cord with potentially dangerous clinical consequences. Other tumors of the umbilical cord are myxoma, angioma and teratoma are differential diagnosis.

  10. Estimation of neonatal outcome artery pH value according to CTG interpretation of the last 60 min before delivery: a retrospective study. Can the outcome pH value be predicted?

    PubMed

    Kundu, S; Kuehnle, E; Schippert, C; von Ehr, J; Hillemanns, P; Staboulidou, Ismini

    2017-11-01

    The aim of this study was to analyze whether the umbilical artery pH value can be estimated throughout CTG assessment 60 min prior to delivery and if the estimated umbilical artery pH value correlates with the actual one. This includes analysis of correlation between CTG trace classification and actual umbilical artery pH value. Intra-and interobserver agreement and the impact of professional experience on visual analysis of fetal heart rate tracing were evaluated. This was a retrospective study. 300 CTG records of the last 60 min before delivery were picked randomly from the computer database with the following inclusion criteria; singleton pregnancy >37 weeks, no fetal anomalies, vaginal delivery either spontaneous or instrumental-assisted. Five obstetricians and two midwives of different professional experience classified 300 CTG traces according to the FIGO criteria and estimated the postnatal umbilical artery pH. The results showed a significant difference (p < 0.05) in estimated and actual pH value, independent of professional experience. Analysis and correlation of CTG assessment and actual umbilical artery pH value showed significantly (p < 0.05) diverging results. Intra- and interobserver variability was high. Intraobserver variability was significantly higher for the resident (p = 0.001). No significant differences were detected regarding interobserver variability. An estimation of the pH value and consequently of neonatal outcome on the basis of a present CTG seems to be difficult. Therefore, not only CTG training but also clinical experience and the collaboration and consultation within the whole team is important.

  11. Agenesis of the venous duct: two cases of extrahepatic drainage of the umbilical vein and extrahepatic portosystemic shunt with a review of the literature.

    PubMed

    Loomba, Rohit S; Frommelt, Michele; Moe, David; Shillingford, Amanda J

    2015-02-01

    Agenesis of the venous duct is a rare congenital anomaly resulting in abnormal drainage of the umbilical vein into the foetal venous circulation. The clinical presentation and prognosis is variable, and may depend on the specific drainage pathways of the umbilical vein. We present two foetuses with agenesis of the venous duct, both associated with a postnatal portosystemic shunt, but with markedly different postnatal clinical courses. We also review all previously reported cases to better characterise this foetal disorder and the prognosis.

  12. A risk score for predicting coronary artery disease in women with angina pectoris and abnormal stress test finding.

    PubMed

    Lo, Monica Y; Bonthala, Nirupama; Holper, Elizabeth M; Banks, Kamakki; Murphy, Sabina A; McGuire, Darren K; de Lemos, James A; Khera, Amit

    2013-03-15

    Women with angina pectoris and abnormal stress test findings commonly have no epicardial coronary artery disease (CAD) at catheterization. The aim of the present study was to develop a risk score to predict obstructive CAD in such patients. Data were analyzed from 337 consecutive women with angina pectoris and abnormal stress test findings who underwent cardiac catheterization at our center from 2003 to 2007. Forward selection multivariate logistic regression analysis was used to identify the independent predictors of CAD, defined by ≥50% diameter stenosis in ≥1 epicardial coronary artery. The independent predictors included age ≥55 years (odds ratio 2.3, 95% confidence interval 1.3 to 4.0), body mass index <30 kg/m(2) (odds ratio 1.9, 95% confidence interval 1.1 to 3.1), smoking (odds ratio 2.6, 95% confidence interval 1.4 to 4.8), low high-density lipoprotein cholesterol (odds ratio 2.9, 95% confidence interval 1.5 to 5.5), family history of premature CAD (odds ratio 2.4, 95% confidence interval 1.0 to 5.7), lateral abnormality on stress imaging (odds ratio 2.8, 95% confidence interval 1.5 to 5.5), and exercise capacity <5 metabolic equivalents (odds ratio 2.4, 95% confidence interval 1.1 to 5.6). Assigning each variable 1 point summed to constitute a risk score, a graded association between the score and prevalent CAD (ptrend <0.001). The risk score demonstrated good discrimination with a cross-validated c-statistic of 0.745 (95% confidence interval 0.70 to 0.79), and an optimized cutpoint of a score of ≤2 included 62% of the subjects and had a negative predictive value of 80%. In conclusion, a simple clinical risk score of 7 characteristics can help differentiate those more or less likely to have CAD among women with angina pectoris and abnormal stress test findings. This tool, if validated, could help to guide testing strategies in women with angina pectoris. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Hepatectomy for cholangiocarcinoma complicated with right umbilical portion: anomalous configuration of the intrahepatic biliary tree.

    PubMed

    Kaneoka, Y; Yamaguchi, A; Isogai, M; Harada, T

    2000-01-01

    The right umbilical portion (right-sided round ligament) has been discussed as an intrahepatic portal venous anomaly associated with "left-sided gallbladder" in several reports. We treated two patients with right umbilical portion (RUP) associated with cholangiocarcinoma. Left hepatectomies were performed, preserving the residual hepatic blood flow and biliary continuity. From our experience in these patients we propose the presence of anomalous configuration of the intrahepatic biliary tree in RUP, because both patients showed medial segmental bile ducts ramified from the right and left hepatic ducts. In general, although the medial segmental bile duct ramified from the left, we surmised that this abnormal bilateral drainage pattern may not be a rare phenomenon in RUP. Special attention may be required to focus on the anatomy of the portal tributaries and biliary ramifications in RUP.

  14. Genetics Home Reference: pulmonary arterial hypertension

    MedlinePlus

    ... Home Health Conditions Pulmonary arterial hypertension Pulmonary arterial hypertension Printable PDF Open All Close All Enable Javascript ... view the expand/collapse boxes. Description Pulmonary arterial hypertension is a progressive disorder characterized by abnormally high ...

  15. Spontaneous Endometriosis Within a Primary Umbilical Hernia

    PubMed Central

    Yheulon, Christopher G

    2017-01-01

    Umbilical hernias are rather common in the General Surgery clinic; however, endometriosis of an umbilical hernia is rare. It is especially unusual to have endometriosis of an umbilical hernia spontaneously occur compared to occurring at a site of a prior surgery. We present a case of spontaneous endometriosis of an umbilical hernia without prior surgery to her umbilicus. She had not presented with the usual symptoms of endometriosis and it was not considered as a diagnosis prior to surgery. Umbilical endometriosis is rare but usually occurs after prior laparoscopic surgery. We believe this is the second reported case in the English literature and the first such case reported from North America of spontaneous endometriosis of an umbilical hernia. This case highlights the importance of a full review of systems and qualifying the type and occurrence of pain. Additionally, it is always important to analyze surgical specimens in pathology to avoid errors in diagnosis. PMID:29164008

  16. Spontaneous Endometriosis Within a Primary Umbilical Hernia.

    PubMed

    Laferriere, Nicole R; Yheulon, Christopher G

    2017-11-01

    Umbilical hernias are rather common in the General Surgery clinic; however, endometriosis of an umbilical hernia is rare. It is especially unusual to have endometriosis of an umbilical hernia spontaneously occur compared to occurring at a site of a prior surgery. We present a case of spontaneous endometriosis of an umbilical hernia without prior surgery to her umbilicus. She had not presented with the usual symptoms of endometriosis and it was not considered as a diagnosis prior to surgery. Umbilical endometriosis is rare but usually occurs after prior laparoscopic surgery. We believe this is the second reported case in the English literature and the first such case reported from North America of spontaneous endometriosis of an umbilical hernia. This case highlights the importance of a full review of systems and qualifying the type and occurrence of pain. Additionally, it is always important to analyze surgical specimens in pathology to avoid errors in diagnosis.

  17. Umbilical cord mesenchymal stem cell (UC-MSC) transplantations for cerebral palsy

    PubMed Central

    Dong, Huajiang; Li, Gang; Shang, Chongzhi; Yin, Huijuan; Luo, Yuechen; Meng, Huipeng; Li, Xiaohong; Wang, Yali; Lin, Ling; Zhao, Mingliang

    2018-01-01

    This study reports a case of a 4-year-old boy patient with abnormalities of muscle tone, movement and motor skills, as well as unstable gait leading to frequent falls. The results of the electroencephalogram (EEG) indicate moderately abnormal EEG, accompanied by irregular seizures. Based on these clinical characteristics, the patient was diagnosed with cerebral palsy (CP) in our hospital. In this study, the patient was treated with umbilical cord mesenchymal stem cell (UC-MSC) transplantation therapy. This patient received UC-MSC transplantation 3 times (5.3*107) in total. After three successive cell transplantations, the patient recovered well and showed obvious improvements in EEG and limb strength, motor function, and language expression. However, the improvement in intelligence quotient (IQ) was less obvious. These results indicate that UC-MSC transplantation is a promising treatment for cerebral palsy. PMID:29636880

  18. Coronary artery to pulmonary artery fistula.

    PubMed

    Dadkhah-Tirani, Heidar; Salari, Arsalan; Shafighnia, Shora; Hosseini, Seyed Fazel; Naghdipoor, Misa

    2013-01-01

    Male, 69 FINAL DIAGNOSIS: Coronary artery to pulmonary artery fistula Symptoms: Chest pain Medication: - Clinical Procedure: Echocardiography • angiography • surgical intervention Specialty: Cardiology • Cardiac Surgery. Rare disease. A coronary artery fistula is an abnormal communication between a coronary artery and one of the cardiac chambers or a great vessel, so bypassing the myocardial capillary network. They are usually discovered incidentally upon coronary angiography. Clinical manifestations are variable depending on the type of fistula, the severity of shunt, site of shunt, and presence of other cardiac condition. We report a 69-year-old man without any previous medical history, who was admitted to our hospital with chest pain. The electrocardiogram (ECG) showed a sinus rhythm with ST depression in V2 to V6 precordial leads. Coronary angiography revealed a coronary artery fistula from left anterior descending coronary artery (LAD) to the main pulmonary artery, right coronary artery blockage and significant stenoses on the LAD and left circumflex artery (LCX). Surgical treatment was chosen because of the total occlusion of the right coronary artery and to relieve of pain to improve quality of life.

  19. Variations of pulmonary arteries and other associated defects in Tetralogy of Fallot.

    PubMed

    Sheikh, Abdul Malik; Kazmi, Uzma; Syed, Najam Hyder

    2014-01-01

    The objective of study was to determine pulmonary artery variations and other associated cardiac defects in patients with Tetralogy of Fallot. This cross-sectional, descriptive study was carried out at The Children's Hospital and the Institute of Child Health, Lahore, from January 2006 to December 2012. All patients with Tetralogy of Fallot, who underwent cardiac catheterization during this period, were included. Standard cine-angiograms were done to record the pulmonary artery sizes and associated cardiac defects. A total of 576 patients with Tetralogy of Fallot were catheterized. Pulmonary Artery abnormalities were present in 109 (18.92%) patients. The commonest abnormality was isolated Left Pulmonary Artery stenosis (n = 60, 10.4%) followed by supra-valvular stenosis (n = 9, 1.6%). Left Pulmonary Artery was absent in seven patients(1.2%), while 1 patient (0.2%) had both absent right and left Pulmonary Arteries with segmental branch pulmonary arteries originating directly from Main Pulmonary Artery. Associated cardiac lesions included right aortic arch in 72 (12.5%), additional muscular Ventricular Septal Defect in 31 (5.4%), Patent Ductus Arteriosus in 31 (5.4%), bilateral Superior Vena Cava 36(6.2%), Atrial Septal Defect 4(0.7%) and Major Aortopulmonary Collateral Arteries in 75(13%) patients. Significant coronary artery abnormalities were present in 28(4.9%) children. Pulmonary artery abnormalities were present in 18.92% of patients with Tetralogy of Fallot. Isolated Left Pulmonary Artery origin stenosis was the most common abnormality. Significant associated cardiac lesions including Patent Ductus Arteriosus , additional muscular Ventricular Septal Defect, coronary artery abnormalities, bilateral Superior Vena Cava, Atrial Septal Defect and Major Aortopulmonary Collateral Arteries were present in one-third of the patients.

  20. Haemodynamic effects of umbilical cord milking in premature sheep during the neonatal transition.

    PubMed

    Blank, Douglas A; Polglase, Graeme R; Kluckow, Martin; Gill, Andrew William; Crossley, Kelly J; Moxham, Alison; Rodgers, Karyn; Zahra, Valerie; Inocencio, Ishmael; Stenning, Fiona; LaRosa, Domeic A; Davis, Peter G; Hooper, Stuart B

    2017-12-05

    Umbilical cord milking (UCM) at birth may benefit preterm infants, but the physiological effects of UCM are unknown. We compared the physiological effects of two UCM strategies with immediate umbilical cord clamping (UCC) and physiological-based cord clamping (PBCC) in preterm lambs. At 126 days' gestational age, fetal lambs were exteriorised, intubated and instrumented to measure umbilical, pulmonary and cerebral blood flows and arterial pressures. Lambs received either (1) UCM without placental refill (UCMwoPR); (2) UCM with placental refill (UCMwPR); (3) PBCC, whereby ventilation commenced prior to UCC; or (4) immediate UCC. UCM involved eight milks along a 10 cm length of cord, followed by UCC. A net volume of blood was transferred into the lamb during UCMwPR (8.8 mL/kg, IQR 8-10, P=0.01) but not during UCMwoPR (0 mL/kg, IQR -2.8 to 1.7) or PBCC (1.1 mL/kg, IQR -1.3 to 4.3). UCM had no effect on pulmonary blood flow, but caused large fluctuations in mean carotid artery pressures (MBP) and blood flows (CABF). In UCMwoPR and UCMwPR lambs, MBP increased by 12%±1% and 8%±1% and CABF increased by 32%±2% and 15%±2%, respectively, with each milk. Cerebral oxygenation decreased the least in PBCC lambs (17%, IQR 13-26) compared with UCMwoPR (26%, IQR 23-25, P=0.03), UCMwPR (35%, IQR 27-44, P=0.02) and immediate UCC (34%, IQR 28-41, P=0.02) lambs. UCMwoPR failed to provide placental transfusion, and UCM strategies caused considerable haemodynamic disturbance. UCM does not provide the same physiological benefits of PBCC. Further review of UCM is warranted before adoption into routine clinical practice. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. [Umbilical hernia repair in conjunction with abdominoplasty].

    PubMed

    Bai, Ming; Dai, Meng-Hua; Huang, Jiu-Zuo; Qi, Zheng; Lin, Chen; Ding, Wen-Yun; Zhao, Ru

    2012-09-01

    To investigate the feasibility and clinical benefits of umbilical hernia repair in conjunction with abdominoplasty. The incision was designed in accord with abdominoplasty. The skin and subcutaneous tissue was dissected toward the costal arch, and then the anterior sheath of rectus abdominus was exposed. After exposure and dissection of the sac of umbilical hernia, tension-free hernioplasty was performed with polypropylene mesh. After dissecting the redundant skin and subcutaneous tissue, the abdominal wall was tightened. Between May 2008 and May 2011, ten patients were treated in the way mentioned above. The repair of umbilical hernia and the correction of abdominal wall laxity were satisfactory. There was no recurrence of umbilical hernia, hematoma, seroma or fat liquefaction. Through careful selection of patients, repair of umbilical hernia and body contouring could be achieved simultaneously.

  2. Risk of ultrasound-detected neonatal brain abnormalities in intrauterine growth-restricted fetuses born between 28 and 34 weeks' gestation: relationship with gestational age at birth and fetal Doppler parameters.

    PubMed

    Cruz-Martinez, R; Tenorio, V; Padilla, N; Crispi, F; Figueras, F; Gratacos, E

    2015-10-01

    To estimate the value of gestational age at birth and fetal Doppler parameters in predicting the risk of neonatal cranial abnormalities in intrauterine growth-restricted (IUGR) fetuses born between 28 and 34 weeks' gestation. Fetal Doppler parameters including umbilical artery (UA), middle cerebral artery (MCA), aortic isthmus, ductus venosus and myocardial performance index were evaluated in a cohort of 90 IUGR fetuses with abnormal UA Doppler delivered between 28 and 34 weeks' gestation and in 90 control fetuses matched for gestational age. The value of gestational age at birth and fetal Doppler parameters in predicting the risk of ultrasound-detected cranial abnormalities (CUA), including intraventricular hemorrhage, periventricular leukomalacia and basal ganglia lesions, was analyzed. Overall, IUGR fetuses showed a significantly higher incidence of CUA than did control fetuses (40.0% vs 12.2%, respectively; P < 0.001). Within the IUGR group, all predictive variables were associated individually with the risk of CUA, but fetal Doppler parameters rather than gestational age at birth were identified as the best predictor. MCA Doppler distinguished two groups with different degrees of risk of CUA (48.5% vs 13.6%, respectively; P < 0.01). In the subgroup with MCA vasodilation, presence of aortic isthmus retrograde net blood flow, compared to antegrade flow, allowed identification of a subgroup of cases with the highest risk of CUA (66.7% vs 38.6%, respectively; P < 0.05). Evaluation of fetal Doppler parameters, rather than gestational age at birth, allows identification of IUGR preterm fetuses at risk of neonatal brain abnormalities. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  3. Concomitant Abdominoplasty and Laparoscopic Umbilical Hernia Repair.

    PubMed

    van Schalkwyk, Constant P; Dusseldorp, Joseph R; Liang, Derek G; Keshava, Anil; Gilmore, Andrew J; Merten, Steve

    2018-04-20

    Umbilical hernia is a common finding in patients undergoing abdominoplasty, especially those who are post-partum with rectus divarication. Concurrent surgical treatment of the umbilical hernia at abdominoplasty presents a "vascular challenge" due to the disruption of dermal blood supply to the umbilicus, leaving the stalk as the sole axis of perfusion. To date, there have been no surgical techniques described to adequately address large umbilical herniae during abdominoplasty. To present an effective and safe technique that can address large umbilical herniae during abdominoplasty. A prospective series of 10 consecutive patients, undergoing concurrent abdominoplasty and laparoscopic umbilical hernia repair between 2014 and 2017 were included in the study. All procedures were performed by the same general surgeon and plastic surgeon at the Macquarie University Hospital in North Ryde, NSW, Australia. Data was collected with approval of our ethics committee. At 12-month follow-up there were no instances of umbilical necrosis, wound complications, seroma or recurrent hernia. The mean body mass index was 23.8 kg/m2 (range, 16.1-30.1 kg/m2). Rectus divarication ranged from 35-80 mm (mean, 53.5 mm). Umbilical hernia repair took a mean of 25.9 minutes to complete (range, 18-35 minutes). We present a technique that avoids incision of the rectus fascia minimizes dissection of the umbilical stalk and is able to provide a gold standard hernia repair with mesh. This procedure is particularly suited to post-partum patients with large herniae (>3-4 cm diameter) and wide rectus divarication, where mesh repair with adequate overlap is the recommended treatment.

  4. Therapy of umbilical hernia during laparoscopic cholecystectomy.

    PubMed

    Zoricić, Ivan; Vukusić, Darko; Rasić, Zarko; Schwarz, Dragan; Sever, Marko

    2013-09-01

    The aim of this study is to show our experience with umbilical hernia herniorrhaphy and laparoscopic cholecystectomy, both in the same act. During last 10 years we operated 89 patients with cholecystitis and pre-existing umbilical hernia. In 61 of them we performed standard laparoscopic cholecystectomy and additional sutures of abdominal wall, and in 28 patients we performed in the same act laparoscopic cholecystectomy and herniorrhaphy of umbilical hernia. We observed incidence of postoperative herniation, and compared patients recovery after herniorrhaphy combined with laparoscopic cholecystectomy in the same act, and patients after standard laparoscopic cholecystectomy and additional sutures of abdominal wall. Patients, who had in the same time umbilical hernia herniorrhaphy and laparoscopic cholecystectomy, shown better postoperative recovery and lower incidence of postoperative umbilical hernias then patients with standard laparoscopic cholecystectomy and additional abdominal wall sutures.

  5. Fetal umbilical artery Doppler pulsatility index and childhood neurocognitive outcome at 12 years

    PubMed Central

    Mone, Fionnuala; McConnell, Barbara; Thompson, Andrew; Segurado, Ricardo; Hepper, Peter; Stewart, Moira C; Dornan, James C; Ong, Stephen; McAuliffe, Fionnuala M; Shields, Michael D

    2016-01-01

    Objective To determine whether an elevated fetal umbilical artery Doppler (UAD) pulsatility index (PI) at 28 weeks’ gestation, in the absence of fetal growth restriction (FGR) and prematurity, is associated with adverse neurocognitive outcome in children aged 12 years. Methods Prospective cohort study, comparing children with a normal fetal UAD PI (<90th centile) (n=110) and those with an elevated PI (≥90th centile) (n=40). UAD was performed at 28, 32 and 34 weeks gestation. At 12 years of age, all children were assessed under standardised conditions at Queen's University, Belfast, UK to determine cognitive and behavioural outcomes using the British Ability Score-II and Achenbach Child Behavioural Checklist Parent Rated Version under standardised conditions. Regression analysis was performed, controlling for confounders such as gender, socioeconomic status and age at assessment. Results The mean age of follow-up was 12.4 years (±0.5 SD) with 44% of children male (n=63). When UAD was assessed at 28 weeks, the elevated fetal UAD group had lower scores in cognitive assessments of information processing and memory. Parameters included (1) recall of objects immediate verbal (p=0.002), (2) delayed verbal (p=0.008) and (3) recall of objects immediate spatial (p=0.0016). There were no significant differences between the Doppler groups at 32 or 34 weeks' gestation. Conclusions An elevated UAD PI at 28 weeks' gestation in the absence of FGR or prematurity is associated with lower scores of declarative memory in children aged 12 years. A potential explanation for this is an element of placental insufficiency in the presence of the appropriately grown fetus, which affects the development of the fetal hippocampus and information processing and memory long-term. These findings, however, had no impact on overall academic ability, mental processing and reasoning or overall behavioural function. PMID:27311899

  6. Fetal umbilical artery Doppler pulsatility index and childhood neurocognitive outcome at 12 years.

    PubMed

    Mone, Fionnuala; McConnell, Barbara; Thompson, Andrew; Segurado, Ricardo; Hepper, Peter; Stewart, Moira C; Dornan, James C; Ong, Stephen; McAuliffe, Fionnuala M; Shields, Michael D

    2016-06-15

    To determine whether an elevated fetal umbilical artery Doppler (UAD) pulsatility index (PI) at 28 weeks' gestation, in the absence of fetal growth restriction (FGR) and prematurity, is associated with adverse neurocognitive outcome in children aged 12 years. Prospective cohort study, comparing children with a normal fetal UAD PI (<90th centile) (n=110) and those with an elevated PI (≥90th centile) (n=40). UAD was performed at 28, 32 and 34 weeks gestation. At 12 years of age, all children were assessed under standardised conditions at Queen's University, Belfast, UK to determine cognitive and behavioural outcomes using the British Ability Score-II and Achenbach Child Behavioural Checklist Parent Rated Version under standardised conditions. Regression analysis was performed, controlling for confounders such as gender, socioeconomic status and age at assessment. The mean age of follow-up was 12.4 years (±0.5 SD) with 44% of children male (n=63). When UAD was assessed at 28 weeks, the elevated fetal UAD group had lower scores in cognitive assessments of information processing and memory. Parameters included (1) recall of objects immediate verbal (p=0.002), (2) delayed verbal (p=0.008) and (3) recall of objects immediate spatial (p=0.0016). There were no significant differences between the Doppler groups at 32 or 34 weeks' gestation. An elevated UAD PI at 28 weeks' gestation in the absence of FGR or prematurity is associated with lower scores of declarative memory in children aged 12 years. A potential explanation for this is an element of placental insufficiency in the presence of the appropriately grown fetus, which affects the development of the fetal hippocampus and information processing and memory long-term. These findings, however, had no impact on overall academic ability, mental processing and reasoning or overall behavioural function. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a

  7. Combined anatomical and functional imaging using coronary CT angiography and myocardial perfusion SPECT in symptomatic adults with abnormal origin of a coronary artery.

    PubMed

    Uebleis, C; Groebner, M; von Ziegler, F; Becker, A; Rischpler, C; Tegtmeyer, R; Becker, C; Lehner, S; Haug, A R; Cumming, P; Bartenstein, P; Franz, W M; Hacker, M

    2012-10-01

    There has been a lack of standardized workup guidelines for patients with congenital abnormal origin of a coronary artery from the opposite sinus (ACAOS). We aimed to evaluate the use of cardiac hybrid imaging using multi-detector row CT (MDCT) for coronary CT angiography (Coronary CTA) and stress-rest myocardial perfusion SPECT (MPS) for comprehensive diagnosis of symptomatic adult patients with ACAOS. Seventeen symptomatic patients (12 men; 54 ± 13 years) presenting with ACAOS underwent coronary CTA and MPS. Imaging data were analyzed by conventional means, and with additional use of 3D image fusion to allocate stress induced perfusion defects (PD) to their supplying coronary arteries. An anomalous RCA arose from the left anterior sinus in eight patients, an abnormal origin from the right sinus was detected in nine patients (5 left coronary arteries, LCA and 4 LCx). Five of the 17 patients (29%) demonstrated a reversible PD in MPS. There was no correlation between the anatomical variants of ACAOS and the presence of myocardial ischemia. Image fusion enabled the allocation of reversible PD to the anomalous vessel in three patients (two cases in the RCA and the other in the LCA territory); PD in two patients were allocated to the territory of artery giving rise to the anomalies, rather than the anomalies themselves. In a small cohort of adult symptomatic patients with ACAOS anomaly there was no relation found between the specific anatomical variant and the appearance of stress induced myocardial ischemia using cardiac hybrid imaging.

  8. Surgical anatomy and morphologic variations of umbilical structures.

    PubMed

    Fathi, Amir H; Soltanian, Hooman; Saber, Alan A

    2012-05-01

    The umbilicus is the main access route to the abdominal cavity in laparoscopic surgeries. However, its anatomical configuration is rarely studied in the surgical and anatomical literature. With introduction of laparoendoscopic single-site surgery and considering the significant number of primary and postoperative umbilical hernias, we felt the necessity to comprehensively study the umbilical structures and analyze their protective function against hernias. Twenty-four embalmed cadavers were studied in the anatomy laboratory of Case Western Reserve University. Round hepatic, median and medial ligaments, umbilical ring, umbilical and umbilicovesicular fasciae, and pattern of attachment to the ring were dissected and measured. Mean age was 82.1 years, ranging between 56 and 96 years, with a male-to-female ratio of 1.4:1. Ninety-two per cent was white and 8 per cent black adults. According to shape and attachment pattern of ligaments, umbilical ring is classified into five types. Hernia incidence was 25 per cent. All hernia cases lacked the umbilical fascia and the round hepatic ligament was not attached to the inferior border of the ring. The umbilical ring and its morphologic relation with adjacent ligaments are described and classified into five types. In contrary to sparse existing literature, we propose that umbilical fascia is continuation and condensation of umbilicovesicular rather than transversalis fascia. It was absent in cadavers forming conjoined median and medial ligaments with a single insertion site to the ring. Round ligament insertion to the inferior border of the ring provides another protective factor. These two protective measures were absent in all the observed umbilical hernias.

  9. Conversion of umbilical arterial Doppler waveforms to cardiac cycle triggering signals: a preparatory study for online motion-gated three-dimensional fetal echocardiography.

    PubMed

    Deng, J; Birkett, A G; Kalache, K D; Hanson, M A; Peebles, D M; Linney, A D; Lees, W R; Rodeck, C H

    2001-01-01

    To remove motion artefacts, a device was built to convert "noisy" umbilical arterial Doppler waveforms (UADWs) from an ultrasound (US) system into sharp ECG R-wave-like cardiac cycle triggering signals (CCTSs). These CCTSs were then used to gate a simultaneous (online) 3-D acquisition of sectional fetal echocardiograms from another US system. To test the conversion performance, a study was carried out in sheep fetal twins. Pulmonary arterial flow waveforms (PAFWs) from implanted probes were traced, in the meantime, to determine the reference cardiac cycle. Interference caused by running the two nonsynchronised US systems was controlled to three degrees (not-noticeable, moderate, and severe), together with high (> or = 40 cm/s) and low (< 40) flow velocities on UADWs. The conversion efficiency, assessed by the percentage of UADWs converted into CCTSs, was in the range of 83% to 100% for not-noticeable and moderate interference, and 0% to 71% for severe interference. The triggering accuracy, assessed by [(time lag mean between the onsets of PAFWs and corresponding CCTSs) -- (its 99% confidence level)] / the mean, was 90% to 96% for the not-noticeable interference high- and low-flow groups and for the moderate interference high-flow group; 19% to 93% for the moderate interference low-flow group; and from not obtainable up to 90% for the severe interference groups. The results show that UADWs can be used as a satisfactory online motion-gating source even in the presence of moderate interference. The major problems are from severe interference or moderate interference with low-flow velocity, which can be minimised/eliminated by the integration of the individual systems involved.

  10. Doppler ultrasound evaluation in preeclampsia

    PubMed Central

    2013-01-01

    Background Worldwide preeclampsia (PE) is the leading cause of maternal death and affects 5 to 8% of pregnant women. PE is characterized by elevated blood pressure and proteinuria. Doppler Ultrasound (US) evaluation has been considered a useful method for prediction of PE; however, there is no complete data about the most frequently altered US parameters in the pathology. The aim of this study was to evaluate the uterine, umbilical, and the middle cerebral arteries using Doppler US parameters [resistance index (RI), pulsatility index (PI), notch (N), systolic peak (SP) and their combinations] in pregnant women, in order to make a global evaluation of hemodynamic repercussion caused by the established PE. Results A total of 102 pregnant Mexican women (65 PE women and 37 normotensive women) were recruited in a cases and controls study. Blood velocity waveforms from uterine, umbilical, and middle cerebral arteries, in pregnancies from 24 to 37 weeks of gestation were recorded by trans-abdominal examination with a Toshiba Ultrasound Power Vision 6000 SSA-370A, with a 3.5 MHz convex transducer. Abnormal general Doppler US profile showed a positive association with PE [odds ratio (OR) = 2.93, 95% confidence interval (CI) = 1.2 - 7.3, P = 0.021)], and a specificity and predictive positive value of 89.2% and 88.6%, respectively. Other parameters like N presence, RI and PI of umbilical artery, as well as the PI of middle cerebral artery, showed differences between groups (P values < 0.05). Conclusion General Doppler US result, as well as N from uterine vessel, RI from umbilical artery, and PI from umbilical and middle cerebral arteries in their individual form, may be considered as tools to determine hemodynamic repercussion caused by PE. PMID:24252303

  11. The TRAP (twin reversed arterial perfusion) sequence - case presentation.

    PubMed

    Mărginean, Claudiu; Mărginean, Maria Oana; Mureşan, Daniel; Zahiu, LuminiŢa; Horváth, Emőke

    2016-01-01

    We present a particular case of TRAP (twin reversed arterial perfusion) syndrome, which has a very rarely association of the simultaneous existence of a rudimentary malformed heart and brain, and also other malformations like abdominal wall abnormality, absent bladder with present kidneys, and absence of the lungs, which appear only in a few cases on the receptor twin from this sequence, malformations incompatible with life. A Caucasian 26-year-old pregnant woman, at the first pregnancy, with a monochorionic-diamniotic pregnancy, 26 weeks of gestation was referred to our hospital, for polyhydramnios. The patient delivered a living female newborn, weighing 950 g, with an Apgar score of 2 at one minute - the donor fetus and a second female newborn with multiple malformations, no signs of life and who weighed 2300 g - the receptor fetus. The anatomopathological examination confirmed the TRAP sequence associated with severe facial dysmorphism, bilateral phocomelia and cardiac malformations (rudimentary hypoplastic, univentricular) and a vascular anastomosis between the two umbilical cords. Anemia and cardiac complications which can lead to cardiac failure, appear early during pregnancy and caused the death of the pumping twin. We emphasize that in our case of TRAP sequence, the ultrasound examination established the diagnosis of the syndrome with high accuracy. Therefore, we can conclude that the existence of a rudimentary heart and a vascular anastomosis between the two umbilical cords supports the apparition of TRAP sequence. The early diagnosis of this pathology, the observation of the pregnancy with the help of weekly ultrasounds and the intrauterine interventions can increase the survival chances of the donor fetus from the TRAP sequence.

  12. Survival Rate without Brain Abnormalities on Postnatal Ultrasonography among Monochorionic Twins after Fetoscopic Laser Photocoagulation for Selective Intrauterine Growth Restriction with Concomitant Oligohydramnios.

    PubMed

    Ishii, Keisuke; Wada, Seiji; Takano, Mayumi; Nakata, Masahiko; Murakoshi, Takeshi; Sago, Haruhiko

    2018-02-20

    We aimed to clarify the survival rate without brain abnormalities (BA) after fetoscopic laser photoco-agulation (FLP) for monochorionic diamniotic twin gestations (MCDA) with selective intrauterine growth restriction (sIUGR) accompanied by abnormal umbilical artery (UA) Doppler waveforms and isolated oligohydramnios in the sIUGR twin. This retrospective study included 52 cases that underwent FLP. The main outcome was survival rate without BA of the twins at age 28 days. BA was defined as severe intraventricular hemorrhage and periventricular leukomalacia on postnatal ultrasonography. Median gestational age at FLP was 20 (16-24) weeks. Ten cases were classified as type III based on Doppler for the UA. For all cases, including 20 cases of anterior placenta, FLP was completed without major intraoperative complications. Amnioinfusion was required in 49 cases for better fetoscopic visualization. Fetal loss occurred in 29 sIUGR twins and two larger twins, whereas one larger twin experienced neonatal death. Survival rates without BA were 44% (n = 23) for sIUGR twins and 94% (n = 49) for the larger twins. FLP for MCDA with sIUGR presenting with oligohydramnios in the sIUGR twin might be considered a prenatal treatment option. © 2018 S. Karger AG, Basel.

  13. [Early child morbidity and late development following primary abdominal cesarean section in breech presentation near term].

    PubMed

    Kouam, L; Werner-Spangenberg, I; Saling, E

    1986-09-01

    This study concerns the results obtained in respect of early morbidity and late development of 115 and 57 children, respectively, born between 1978 and 1983, who had been delivered by primary low cervical Caesarean section shortly before term. Early morbidity of the 115 children was analysed taking into consideration the risk factors, such as premature rupture, gestation diabetes, EPH gestosis, condition following Caesarean section, abnormal amnioscopic and antepartal cardiotocographic findings, as well as the methods of anaesthesia employed. In the study on late development 57 children between 1 1/4 and 6 years of age were followed up and examined with regard to several faculties (social contact, fine motoricity and adaptation, speech and gross motoricity) according to the Denver Developmental Screening Test. Children with abnormal findings were subjected to special examination. Children with abnormal findings were also subjected to a positional test according to Vojta and to the Munich functional developmental diagnosis after Hellbrüge et al. While employing physiotherapy after Bobath and early rehabilitation training by the parents, these children were followed up at regular intervals. There was no clinically relevant acidosis in the group of 115 newborn. A total of 44 newborn (38%) displayed slight to medium enhanced acidity (pH value, umbilical artery: 7.20 to 7.29) according to the stage classification after Saling and Wulf. Slight to medium acidosis (umbilical artery pH 7.10 to 7.19) was seen in 3 cases only (2.6%). In 112 newborn we found a correlation between the good Apgar score values (7-10) and normal acidity in the umbilical artery blood (act. umbilical artery pH greater than or equal to 7.30). In the remaining 3 newborn with lower Apgar scores (3-6) there was no acidosis in the umbilical artery blood. In the follow-up group (57 cases) we found one child with psychomotor retardation of speech (disturbed articulation and reduced vocabulary) and 6

  14. Impact of Intended Mode of Delivery on Outcomes in Preterm Growth-Restricted Fetuses.

    PubMed

    Baalbaki, Sima H; Kuper, Spencer G; Wang, Michelle J; Steele, Robin A; Biggio, Joseph R; Harper, Lorie M

    2018-06-01

     Scheduled cesarean is frequently performed for fetal growth restriction due to concerns for fetal intolerance of labor.  We compared neonatal outcomes in preterm growth-restricted fetuses by intended mode of delivery.  We performed a retrospective cohort study of indicated preterm births with prenatally diagnosed growth restriction from 2011 to 2014 at a single institution. Patients were classified by intended mode of delivery. The primary outcome was a composite of adverse neonatal outcomes, including perinatal death, cord blood acidemia, chest compressions during neonatal resuscitation, seizures, culture-proven sepsis, necrotizing enterocolitis, and grade III-IV intraventricular hemorrhage. Secondary analysis was performed examining the impact of umbilical artery Dopplers.  Of 101 fetuses with growth restriction, 75 underwent planned cesarean deliveries. Of those induced, 46.2% delivered vaginally. Delivery by scheduled cesarean was not associated with a decreased risk of the composite outcome (adjusted odds ratio [aOR], 1.61; 95% confidence interval [CI], 0.45-5.78), even when only those with abnormal umbilical artery Dopplers were considered (aOR, 2.8; 95% CI, 0.40-20.2).  In this cohort, planned cesarean was not associated with a reduction in neonatal morbidity, even when considering only those with abnormal umbilical artery Dopplers. In otherwise appropriate candidates for vaginal delivery, fetal growth restriction should not be considered a contraindication to trial of labor. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. Umbilical Hernia Repair: Analysis After 934 Procedures.

    PubMed

    Porrero, José L; Cano-Valderrama, Oscar; Marcos, Alberto; Bonachia, Oscar; Ramos, Beatriz; Alcaide, Benito; Villar, Sol; Sánchez-Cabezudo, Carlos; Quirós, Esther; Alonso, María T; Castillo, María J

    2015-09-01

    There is a lack of consensus about the surgical management of umbilical hernias. The aim of this study is to analyze the medium-term results of 934 umbilical hernia repairs. In this study, 934 patients with an umbilical hernia underwent surgery between 2004 and 2010, 599 (64.1%) of which were evaluated at least one year after the surgery. Complications, recurrence, and the reoperation rate were analyzed. Complications were observed in 5.7 per cent of the patients. With a mean follow-up time of 35.5 months, recurrence and reoperation rates were 3.8 per cent and 4.7 per cent, respectively. A higher percentage of female patients (60.9 % vs 29 %, P = 0.001) and a longer follow-up time (47.4 vs 35 months, P = 0.037) were observed in patients who developed a recurrence. No significant differences were observed between complications and the reoperation rate in patients who underwent Ventralex(®) preperitoneal mesh reinforcement and suture repair; however, a trend toward a higher recurrence rate was observed in patients with suture repair (6.5 % vs 3.2 %, P = 0.082). Suture repair had lower recurrence and reoperation rates in patients with umbilical hernias less than 1 cm. Suture repair is an appropriate procedure for small umbilical hernias; however, for larger umbilical hernias, mesh reinforcement should be considered.

  16. Umbilical Deployment Device

    NASA Technical Reports Server (NTRS)

    Shafer, Michael W.; Gallon, John C.; Rivellini, Tommaso P.

    2011-01-01

    The landing scheme for NASA's next-generation Mars rover will encompass a novel landing technique (see figure). The rover will be lowered from a rocket-powered descent stage and then placed onto the surface while hanging from three bridles. Communication between the rover and descent stage will be maintained through an electrical umbilical cable, which will be deployed in parallel with structural bridles. The -inch (13-mm) umbilical cable contains a Kevlar rope core, around which wires are wrapped to create a cable. This cable is helically coiled between two concentric truncated cones. It is deployed by pulling one end of the cable from the cone. A retractable mechanism maintains tension on the cable after deployment. A break-tie tethers the umbilical end attached to the rover even after the cable is cut after touchdown. This break-tie allows the descent stage to develop some velocity away from the rover prior to the cable releasing from the rover deck, then breaks away once the cable is fully extended. The descent stage pulls the cable up so that recontact is not made. The packaging and deployment technique can store a long length of cable in a relatively small volume while maintaining compliance with the minimum bend radius requirement for the cable being deployed. While the packaging technique could be implemented without the use of break-ties, they were needed in this design due to the vibratory environment and the retraction required by the cable. The break-ties used created a series of load-spikes in the deployment signature. The load spikes during the deployment of the initial three coils of umbilical showed no increase between the different temperature trials. The cold deployment did show an increased load requirement for cable extraction in the region where no break-ties were used. This increase in cable drag was superimposed on the loads required to rupture the last set of break-ties, and as such, these loads saw significant increase when compared to

  17. Arterial switch: translocation of the intramural coronary artery.

    PubMed

    Asou, T; Karl, T R; Pawade, A; Mee, R B

    1994-02-01

    Translocation of an intramural coronary artery is one of the most challenging problems in anatomic correction of transposition of the great arteries. Of 259 patients undergoing arterial switch procedure for transposition of the great arteries in our hospital, 12 (4.6%) were found to have intramural coronary arteries. The diagnosis was made intraoperatively in all patients. There were five different types of intramural coronary anatomy noted, with ostial stenosis present in half. The operative technique consisted of detachment of the posterior commissure of the aortic valve and unroofing of the intramural segment of the coronary artery by excision of a triangular portion of internal aortic wall. The coronary arteries were excised as a single disc, which was divided into two cuffs. The arterial switch was then performed in the usual fashion. The posterior commissure of the aortic valve was resuspended to the pericardial patch used to reconstruct the neopulmonary artery sinus. There were no operative or late deaths over a follow-up of 328 patient-months. Postoperatively, no patient showed ischemic changes on electrocardiogram or abnormal wall motion on echocardiogram. We believe that intramural coronary arteries can be managed satisfactorily with this technique, and that arterial switch will be possible in all cases.

  18. Transcatheter Arterial Embolization for Spontaneous Rupture of the Omental Artery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsumoto, Tomohiro, E-mail: t-matsu@koto.kpu-m.ac.jp; Yamagami, Takuji; Morishita, Hiroyuki

    We encountered a rare case of spontaneous rupture of the omental artery. A 25-year-old man without any episode of abdominal trauma or bleeding disorders came to the emergency unit with left upper abdominal pain. Hematoma with extravasation of the greater omentum and a hemoperitoneum was confirmed on abdominal contrast-enhanced computed tomography. Bleeding from the omental artery was suspected based on these findings. Transcatheter arterial embolization was successfully performed after extravasation of the omental artery, which arises from the left gastroepiploic artery, was confirmed on arteriography. Partial ometectomy was performed 10 days after transcatheter arterial embolization, revealing that the hematoma measuredmore » 10 cm in diameter in the greater omentum. Pathological examination showed rupture of the branch of an omental artery without abnormal findings, such as an aneurysm or neoplasm. Thus, we diagnosed him with spontaneous rupture of the omental artery. The patient recovered and was discharged from the hospital 10 days after the surgery, with a favorable postoperative course.« less

  19. The role of prophylactic internal iliac artery ligation in abnormally invasive placenta undergoing caesarean hysterectomy: a randomized control trial.

    PubMed

    Hussein, Ahmed M; Dakhly, Dina Mohamed Refaat; Raslan, Ayman N; Kamel, Ahmed; Abdel Hafeez, Ali; Moussa, Manal; Hosny, Ahmed Samir; Momtaz, Mohamed

    2018-04-25

    To identify the role of bilateral internal iliac artery (IIA) ligation on reducing blood loss in abnormally invasive placenta (AIP) undergoing caesarean hysterectomy. In this parallel-randomized control trial, 57 pregnant females with ultrasound features suggestive of AIP were enrolled. They were randomized into two groups; IIA group (n = 29 cases) performed bilateral IIA ligation followed by caesarean hysterectomies, while Control group (n = 28 cases) underwent caesarean hysterectomy only. The main outcome was the difference in the estimated intraoperative blood loss between the two groups. There was no significant difference between the two groups regarding the intraoperative estimated blood loss (1632 ± 804 versus 1698 ± 1251, p value .83). The operative procedure duration (minutes) (223 ± 66 versus 171 ± 41.4, p value .001) varied significantly between the two groups. Bilateral internal iliac artery ligation, in cases of AIP undergoing caesarean hysterectomy, is not recommended for routine practice to minimize blood loss intraoperatively.

  20. Umbilical Connect Techniques Improvement-Technology Study

    NASA Technical Reports Server (NTRS)

    Valkema, Donald C.

    1972-01-01

    The objective of this study was to develop concepts, specifications, designs, techniques, and procedures capable of significantly reducing the time required to connect and verify umbilicals for ground services to the space shuttle. The desired goal was to reduce the current time requirement of several shifts for the Saturn 5/Apollo to an elapsed time of less than one hour to connect and verify all of the space shuttle ground service umbilicals. The study was conducted in four phases: (1) literature and hardware examination, (2) concept development, (3) concept evaluation and tradeoff analysis, and (4) selected concept design. The final product of this study was a detail design of a rise-off disconnect panel prototype test specimen for a LO2/LH2 booster (or an external oxygen/hydrogen tank for an orbiter), a detail design of a swing-arm mounted preflight umbilical carrier prototype test specimen, and a part 1 specification for the umbilical connect and verification design for the vehicles as defined in the space shuttle program.

  1. Reference centiles for the middle cerebral artery and umbilical artery pulsatility index and cerebro-placental ratio from a low-risk population - a Generalised Additive Model for Location, Shape and Scale (GAMLSS) approach.

    PubMed

    Flatley, Christopher; Kumar, Sailesh; Greer, Ristan M

    2018-02-06

    The primary aim of this study was to create reference ranges for the fetal Middle Cerebral artery Pulsatility Index (MCA PI), Umbilical Artery Pulsatility Index (UA PI) and the Cerebro-Placental Ratio (CPR) in a clearly defined low-risk cohort using the Generalised Additive Model for Location, Shape and Scale (GAMLSS) method. Prospectively collected cross-sectional biometry and Doppler data from low-risk women attending the Mater Mother's Hospital, Maternal and Fetal Medicine Department in Brisbane, Australia between January 2010 and April 2017 were used to derive gestation specific centiles for the MCA PI, UA PI and CPR. All ultrasound scans were performed between 18 + 0 and 41 + 6 weeks gestation with recorded data for the MCA PI and/or UA PI. The GAMLSS method was used for the calculation of gestational age-adjusted centiles. Distributions and additive terms were assessed and the final model was chosen on the basis of the Global Deviance, Akaike information criterion (AIC) and Schwartz bayesian criterion (SBC), along with the results of the model and residual diagnostics as well as visual assessment of the centiles themselves. Over the study period 6013 women met the inclusion criteria. The MCA PI was recorded in 4473 fetuses, the UA PI in 6008 fetuses and the CPR was able to be calculated in 4464 cases. The centiles for the MCA PI used a fractional polynomial additive term and Box-Cox t (BCT) distribution. Centiles for the UA PI used a cubic spline additive term with BCT distribution and the CPR used a fractional polynomial additive term and a BCT distribution. We have created gestational centile reference ranges for the MCA PI, UA PI and CPR from a large low-risk cohort that supports their applicability and generalisability.

  2. MANAGEMENT OF OMPHALOPHLEBITIS AND UMBILICAL HERNIA IN THREE NEONATAL GIRAFFE (GIRAFFA CAMELOPARDALIS).

    PubMed

    Selig, Michael; Lewandowski, Albert; Burton, Michael S; Ball, Ray L

    2015-12-01

    Umbilical disorders, including omphalophlebitis, omphaloarteritis, external umbilical abscesses, urachal abscesses, patent urachus, and umbilical hernias, represent a significant challenge to the health and well-being of a neonate. The three neonatal giraffe (Giraffa camelopardalis) in this report were evaluated for umbilical swellings. Two developed omphalophlebitis, and one had an uncomplicated umbilical hernia. Omphalophlebitis is an inflammation and/or infection of the umbilical vein. Giraffe calves with a failure of passive transfer may be predisposed and should be thoroughly evaluated for the condition. Umbilical hernias result from a failure of the umbilical ring to close after parturition or from malformation of the umbilical ring during embryogenesis. These problems were surgically corrected for all three individuals, although one died due to postsurgical complications. The risks involved include anesthetic complications, surgical dehiscence, and maternal rejection. Early detection and surgical intervention are recommended for the correction of omphalophlebitis and umbilical hernias in neonatal giraffe.

  3. Rare Abdominal Wall Malformation: Case Report of Umbilical Cord Hernia.

    PubMed

    Gliha, Andro; Car, Andrija; Višnjić, Stjepan; Zupancic, Bozidar; Kondza, Karmen; Petracic, Ivan

    The umbilical cord hernia is the rarest form of abdominal wall malformations, anatomically completely different from gastroschisis and omphalocele. It occurs due to the permanent physiological evisceration of abdominal organs into umbilical celom and persistence of a patent umbilical ring. The umbilical cord hernia is often mistaken for omphalocele and called "small omphalocele". Here we present a case of a female newborn with umbilical cord hernia treated in our Hospital. After preoperative examinations surgery was done on the second day of life. The abdominal wall was closed without tension. The aim of this article is to present the importance of the proper diagnose of these three entities and to stimulate academic community for the answer, is this umbilical cord hernia or small omphalocele.

  4. 1H-NMR-Based Metabolic Profiling of Maternal and Umbilical Cord Blood Indicates Altered Materno-Foetal Nutrient Exchange in Preterm Infants

    PubMed Central

    Küster, Alice; Guignard, Nadia; Alexandre–Gouabau, Marie-Cécile; Darmaun, Dominique; Robins, Richard J.

    2012-01-01

    Background Adequate foetal growth is primarily determined by nutrient availability, which is dependent on placental nutrient transport and foetal metabolism. We have used 1H nuclear magnetic resonance (NMR) spectroscopy to probe the metabolic adaptations associated with premature birth. Methodology The metabolic profile in 1H NMR spectra of plasma taken immediately after birth from umbilical vein, umbilical artery and maternal blood were recorded for mothers delivering very-low-birth-weight (VLBW) or normo-ponderal full-term (FT) neonates. Principal Findings Clear distinctions between maternal and cord plasma of all samples were observed by principal component analysis (PCA). Levels of amino acids, glucose, and albumin-lysyl in cord plasma exceeded those in maternal plasma, whereas lipoproteins (notably low-density lipoprotein (LDL) and very low-density lipoprotein (VLDL) and lipid levels were lower in cord plasma from both VLBW and FT neonates. The metabolic signature of mothers delivering VLBW infants included decreased levels of acetate and increased levels of lipids, pyruvate, glutamine, valine and threonine. Decreased levels of lipoproteins glucose, pyruvate and albumin-lysyl and increased levels of glutamine were characteristic of cord blood (both arterial and venous) from VLBW infants, along with a decrease in levels of several amino acids in arterial cord blood. Conclusion These results show that, because of its characteristics and simple non-invasive mode of collection, cord plasma is particularly suited for metabolomic analysis even in VLBW infants and provides new insights into the materno-foetal nutrient exchange in preterm infants. PMID:22291897

  5. Pregnancy complicated with Alport syndrome: a good obstetric outcome and failure to diagnose an infant born to a mother with Alport syndrome by umbilical cord immunofluorescence staining.

    PubMed

    Matsubara, Shigeki; Ueda, Yoshihiko; Takahashi, Hisako; Nagai, Takashi; Kuwata, Tomoyuki; Muto, Shigeaki; Yamaguchi, Takehiko; Takizawa, Toshihiro; Suzuki, Mitsuaki

    2009-12-01

    Alport syndrome is a familial progressive nephritis. The most frequent type is X-linked Alport syndrome, caused by genetic abnormalities in the alpha 5 chain of type IV collagen. Skin biopsy is a useful tool for diagnosing this disease. It is not well known how this syndrome affects pregnancy and how it is affected by pregnancy, or whether the umbilical cord may provide material for detecting this collagen abnormality. We report a primigravida with Alport syndrome with mild proteinuria who gave birth abdominally to a term male infant without deteriorating renal function during pregnancy. The umbilical cord from not only this infant but also from an Alport (-) control infant showed negative immunofluorescence staining for the alpha 5 chain of type IV collagen. Women with Alport syndrome without renal dysfunction may follow an uneventful obstetrical course until term. The cord may not be suitable for diagnosing Alport syndrome with immunofluorescence staining.

  6. Can flavonoid-rich chocolate modulate arterial elasticity and pathological uterine artery Doppler blood flow in pregnant women? A pilot study.

    PubMed

    von Wowern, Emma; Olofsson, Per

    2018-09-01

    Dark chocolate has shown beneficial effects on cardiovascular health and might also modulate hypertensive complications in pregnancy and uteroplacental blood flow. Increased uteroplacental resistance is associated with systemic arterial stiffness. We aimed to investigate the short-term effect of flavonoid-rich chocolate on arterial stiffness and Doppler blood flow velocimetry indexes in pregnant women with compromised uteroplacental blood flow. Doppler blood flow velocimetry and digital pulse wave analysis (DPA) were performed in 25 women pregnant in the second and third trimesters with uterine artery (UtA) score (UAS) 3-4, before and after 3 days of ingestion of chocolate with high flavonoid and antioxidant contents. UtA pulsatility index (PI), UtA diastolic notching, UAS (semiquantitative measure of PI and notching combined), and umbilical artery PI were calculated, and DPA variables representing central and peripheral maternal arteries were recorded. Mean UtA PI (p = .049) and UAS (p = .025) significantly decreased after chocolate consumption. There were no significant changes in UtA diastolic notching or any DPA indexes of arterial stiffness/vascular tone. Chocolate may have beneficial effects on the uteroplacental circulation, but in this pilot study, we could not demonstrate effects on arterial vascular tone as assessed by DPA.

  7. Discordant Umbilical Cord Drug Testing Results in Monozygotic Twins.

    PubMed

    Alexander, Amy; Abbas, Liaqat; Jones, Mary; Jones, Joseph; Lewis, Douglas; Negrusz, Adam

    2018-06-01

    Our laboratory received segments of umbilical cord that originated from identical twins for routine toxicology analysis. The specimens were analyzed multiple times by liquid chromatography tandem mass spectrometry. The umbilical cord from newborn #1 was positive for hydromorphone only (1.06 ng/g), and the umbilical cord from newborn #2 was positive for hydromorphone (0.81 ng/g) and benzoylecgonine (5.41 ng/g). The hydromorphone results are consistent with maternal administration of hydromorphone; however, the cause of the discrepant benzoylecgonine results in the umbilical cords from the identical twins is unknown.

  8. Umbilical hernia: Influence of adhesive strapping on outcome.

    PubMed

    Hayashida, Makoto; Shimozono, Takashi; Meiri, Satoru; Kurogi, Jun; Yamashita, Naoto; Ifuku, Toshinobu; Yamamura, Yoshiko; Tanaka, Etsuko; Ishii, Shigeki; Shimonodan, Hidemi; Mihara, Yuka; Kono, Keiichiro; Nakatani, Keigo; Nishiguchi, Toshihiro

    2017-12-01

    Adhesive strapping for umbilical hernia has been re-evaluated as a promising treatment. We evaluated the influence of adhesive strapping on the outcome of umbilical hernia. We retrospectively evaluated patients with umbilical hernia referred to the present institution from April 2011 to December 2015. Patients who were treated with adhesive strapping were compared with an observation alone group. The adhesive strapping group was also subdivided into two groups: the cure group and the treatment failure group. A total of 212 patients with umbilical hernia were referred to the present institution. Eighty-nine patients were treated with adhesive strapping, while 27 had observation only. The cure rate in the adhesive strapping group was significantly higher than that in the observation group. The duration of treatment of the adhesive strapping group was significantly shorter than that of the observation group. In the adhesive strapping group, the patients in the cure group were treated significantly earlier than those in the treatment failure group (P < 0.001). Furthermore, even in cases of umbilical hernia non-closure, surgical repair was easier after adhesive strapping. Adhesive strapping represents a promising treatment for umbilical hernia. To achieve the best results, adhesive strapping should be initiated as early as possible. © 2017 Japan Pediatric Society.

  9. Neutral endopeptidase up-regulation in isolated human umbilical artery: involvement in desensitization of bradykinin-induced vasoconstrictor effects.

    PubMed

    Pelorosso, Facundo Germán; Halperin, Ana Verónica; Palma, Alejandro Martín; Nowak, Wanda; Errasti, Andrea Emilse; Rothlin, Rodolfo Pedro

    2007-02-01

    Previous reports show that bradykinin B(2) receptors mediate contractile responses induced by bradykinin (BK) in human umbilical artery (HUA). However, although it has been reported that BK-induced responses can desensitize in several inflammatory models, the effects of prolonged in vitro incubation on BK-induced vasoconstriction in HUA have not been studied. In isolated HUA rings, BK-induced responses after a 5-h in vitro incubation showed a marked desensitization compared with responses at 2 h. Inhibition of either angiotensin-converting enzyme (ACE) or neutral endopeptidase (NEP), both BK-inactivating enzymes, failed to modify responses to BK at 2 h. After 5 h, ACE inhibition produced only a slight potentiation of BK-induced responses. In contrast, BK-induced vasoconstriction at 5 h was markedly potentiated by NEP inhibition. Moreover, NEP activity, measured by hydrolysis of its synthetic substrate (Z-Ala-Ala-Leu-p-nitroanilide), showed a 2.4-fold increase in 5-h incubated versus 2-h incubated tissues, which was completely reversed by cycloheximide (CHX) treatment. Furthermore, CHX significantly potentiated BK-induced responses, suggesting that NEP-mediated kininase activity increase at 5 h depends on de novo protein synthesis. In addition, under NEP inhibition, CHX treatment failed to produce an additional potentiation of BK-induced vasoconstriction. Still, NEP up-regulation was confirmed by Western blot, showing a 2.1-fold increase in immunoreactive NEP in 5-h incubated versus 2-h incubated HUA. In summary, the present study provides strong pharmacological evidence that NEP is up-regulated and plays a key role in desensitization of BK-induced vasoconstriction after prolonged in vitro incubation in HUA. Our results provide new insights into the possible mechanisms involved in BK-induced response desensitization during sustained inflammatory conditions.

  10. Incarceration of a pedunculated uterine fibroid in an umbilical hernia.

    PubMed

    Kim, Mi Ju; Cha, Hyun-Hwa; Seong, Won Joon

    2017-05-01

    Uterine fibroids are common benign tumors that may cause an umbilical hernia in patients with increased intra-abdominal pressure due to pregnancy, obesity, ascites, and intra-abdominal tumors. However, the simultaneous occurrence of uterine fibroids and umbilical hernias, or fibroids and an associated umbilical hernia, during pregnancy has rarely been reported. Here, we present the case of a fibroid presenting as an incarcerated umbilical hernia in a menopausal patient.

  11. Incarceration of a pedunculated uterine fibroid in an umbilical hernia

    PubMed Central

    Kim, Mi Ju; Seong, Won Joon

    2017-01-01

    Uterine fibroids are common benign tumors that may cause an umbilical hernia in patients with increased intra-abdominal pressure due to pregnancy, obesity, ascites, and intra-abdominal tumors. However, the simultaneous occurrence of uterine fibroids and umbilical hernias, or fibroids and an associated umbilical hernia, during pregnancy has rarely been reported. Here, we present the case of a fibroid presenting as an incarcerated umbilical hernia in a menopausal patient. PMID:28534020

  12. Orion Service Module Umbilical (OSMU) Installation

    NASA Image and Video Library

    2017-03-16

    A crane and rigging are used to lift the Orion Service Module Umbilical (OSMU) up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  13. Orion Service Module Umbilical (OSMU) Installation

    NASA Image and Video Library

    2017-03-16

    A crane lifts the Orion Service Module Umbilical (OSMU) high up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  14. Orion Service Module Umbilical (OSMU) Installation

    NASA Image and Video Library

    2017-03-16

    Preparations are underway to lift the Orion Service Module Umbilical (OSMU) up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  15. Orion Service Module Umbilical (OSMU) Installation

    NASA Image and Video Library

    2017-03-16

    Seeming to hang in midair, the Orion Service Module Umbilical (OSMU) is lifted high up by crane for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  16. Orion Service Module Umbilical (OSMU) Installation

    NASA Image and Video Library

    2017-03-16

    A crane and rigging are used to position the Orion Service Module Umbilical (OSMU) for installation high up on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  17. Orion Service Module Umbilical (OSMU) Installation

    NASA Image and Video Library

    2017-03-16

    A crane and rigging are used to lift the Orion Service Module Umbilical (OSMU) high up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  18. Umbilical metastases: current viewpoint

    PubMed Central

    Gabriele, Raimondo; Conte, Marco; Egidi, Federico; Borghese, Mario

    2005-01-01

    Background Umbilical metastases from a malignant neoplasm, also termed Sister Mary Joseph's nodule, are not commonly reported in the English literature, and they have usually been considered as a sign of a poor prognosis for the patient. The present article reports on the current view point on umbilical metastasis besides discussing the epidemiology, clinical presentation, pathophysiology and treatment. Method A search of Pubmed was carried out using the term 'umblic*' and 'metastases' or metastasis' revealed no references. Another search was made using the term "Sister Joseph's nodule" or sister Joseph nodule" that revealed 99 references. Of these there were 14 review articles, however when the search was limited to English language it yielded only 20 articles. Articles selected from these form the basis of this report along with cross references. Results The primary lesions usually arise from gastrointestinal or genitourinary tract malignancies and may be the presenting symptom or sign of a primary tumour in an unknown site. Conclusion A careful evaluation of all umbilical lesions, including an early biopsy if appropriate, is recommended. Recent studies suggest an aggressive surgical approach combined with chemotherapy for such patients may improve survival. PMID:15723695

  19. [Arterial sequelae of pregnancy hypertension. Detection by carotid piezogram].

    PubMed

    Meyer-Heine, A; Asquer, J C; Lagrue, G

    1989-01-01

    High blood pressure (HTA) is characterized by elevation of pression, but also by modifications of arterial pulse wave. Carotid piezograms were used to evaluate arterial pulse wave. Diastolic blood pressure is significantly correlated with dicrotic notch pressure. The duration of dicrotic notch is negatively correlated with arterial wall elasticity. Thus by carotid piezogram analysis one can determine the respective participation of arterial wall elasticity, peripheral resistance and cardiac factors in blood pressure elevation. Carotid piezograms were measured in 97 women (mean age 27, 8 y), with previous hypertensive pregnancy and apparently cured (mean blood pressure 122-74 mmHg at time of examination). 25 women only had normal piezogram drawing. Abnormalities similar to that of permanent hypertensive disease were observed in most cases. Dicrotic notch duration was significantly reduced and dicrotic notch pressure enhanced; in 34 women both of these abnormalities were present. In conclusion, among women previously hypertensive during pregnancy, even when blood pressure is returned to normal, abnormalities of arterial pulse wave may be present, suggesting that these women are prone to subsequent permanent hypertension.

  20. Abnormal origins of the coronary arteries from the aortic root.

    PubMed

    Hoffman, Julien I E

    2014-10-01

    Anomalous origin of a coronary artery from the aorta is a potentially serious anomaly that occurs in about 0.1-0.2% of the population. This percentage is small; however, it translates into about 4000 annual births with these anomalies. The clinical presentation of these anomalies is rare, and hence most are and will remain asymptomatic. The various anatomic anomalies are described, with anomalous origin of the left coronary artery that then passes between the aorta and pulmonary artery being the most serious of these anomalies. The pathophysiology resulting from these anomalies is described, as are methods for identifying those who require treatment; however, we still do not know the best methods of determining which patients need treatment.

  1. [Anomalous systemic arterial supply to normal basal segments of the left lung (Pryce type I)].

    PubMed

    Ryu, Chusei; Sawada, Takahiro; Machino, Ryusuke

    2013-03-01

    Patient 1 was a 54-year-old female diagnosed with anomalous systemic arterial supply to normal basal segments of the left lung discovered as an abnormality on chest X-ray radiography. Patient 2 was a 47-year-old male in whom the disease was diagnosed by close examination of bloody sputum. Division of the abnormal artery and left lower lobectomy were performed in patient 1. Arterial congestion and serpentine distribution were noted in the basal segments of the lung, which was the region perfused by the abnormal artery, on histopathological examination. Arteriosclerotic changes were noted in the vascular wall, but no abnormal vascular wall or alveolar structure was noted in S6, which was not included in theperfused region. Based on the above findings, division of the abnormal artery and left basal segmentectomy were performed in patient 2. Bloody sputum disappeared, and activity of daily living( ADL) were not impaired after surgery.

  2. Histopathology of the great vessels in patients with pulmonary arterial hypertension in association with congenital heart disease: large pulmonary arteries matter too.

    PubMed

    Prapa, Matina; McCarthy, Karen P; Dimopoulos, Konstantinos; Sheppard, Mary N; Krexi, Dimitra; Swan, Lorna; Wort, S John; Gatzoulis, Michael A; Ho, Siew Yen

    2013-10-03

    Pulmonary arterial hypertension (PAH) is considered primarily a disease of the distal pulmonary arteries whereas little is known on the effect of long-standing pulmonary hypertension on the larger proximal pulmonary arteries. This study aims to investigate the structural changes in the great arteries of adults who developed PAH in association with congenital heart disease (CHD), with severe cases termed Eisenmenger syndrome. We performed macroscopic and light microscopy analyses on the great arteries of 10 formalin-fixed human hearts from patients with PAH/CHD and compared them to age-matched healthy controls. A detailed histology grading score was used to assess the severity of medial wall abnormalities. Severe atherosclerotic lesions were found macroscopically in the elastic pulmonary arteries of 4 PAH/CHD specimens and organised thrombi in 3; none were present in the controls. Significant medial wall abnormalities were present in the pulmonary trunk (PT), including fibrosis (80%), and atypical elastic pattern (80%). Cyst-like formations were present in less than one third of patients and were severe in a single case leading to wall rupture. The cumulative PT histology grading score was significantly higher in PAH/CHD cases compared to controls (p<0.0001) and correlated positively with larger PT diameters (ρ=0.812, p<0.0001) and the degree of medial wall hypertrophy (ρ=0.749, p<0.0001). Chronic PAH in association with CHD results in marked macroscopic and histological abnormalities in the large pulmonary arteries. These abnormalities are likely to affect haemodynamics and contribute to morbidity and mortality in this cohort. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  3. Endovascular uterine artery interventions

    PubMed Central

    Das, Chandan J; Rathinam, Deepak; Manchanda, Smita; Srivastava, D N

    2017-01-01

    Percutaneous vascular embolization plays an important role in the management of various gynecologic and obstetric abnormalities. Transcatheter embolization is a minimally invasive alternative procedure to surgery with reduced morbidity and mortality, and preserves the patient's future fertility potential. The clinical indications for transcatheter embolization are much broader and include many benign gynecologic conditions, such as fibroid, adenomyosis, and arteriovenous malformations (AVMs), as well as intractable bleeding due to inoperable advanced-stage malignancies. The most well-known and well-studied indication is uterine fibroid embolization. Uterine artery embolization (UAE) may be performed to prevent or treat bleeding associated with various obstetric conditions, including postpartum hemorrhage (PPH), placental implantation abnormality, and ectopic pregnancy. Embolization of the uterine artery or the internal iliac artery also may be performed to control pelvic bleeding due to coagulopathy or iatrogenic injury. This article discusses these gynecologic and obstetric indications for transcatheter embolization and reviews procedural techniques and outcomes. PMID:29379246

  4. Orion Service Module Umbilical (OSMU) Installation

    NASA Image and Video Library

    2017-03-16

    Construction workers assist as a crane and rigging are used to position the Orion Service Module Umbilical (OSMU) for installation high up on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  5. Chromosomal abnormalities and copy number variations in fetal left-sided congenital heart defects.

    PubMed

    Jansen, Fenna A R; Hoffer, Mariette J V; van Velzen, Christine L; Plati, Stephani Klingeman; Rijlaarsdam, Marry E B; Clur, Sally-Ann B; Blom, Nico A; Pajkrt, Eva; Bhola, Shama L; Knegt, Alida C; de Boer, Marion A; Haak, Monique C

    2016-02-01

    To demonstrate the spectrum of copy number variants (CNVs) in fetuses with isolated left-sided congenital heart defects (CHDs), and analyse genetic content. Between 2003 and 2012, 200 fetuses were identified with left-sided CHD. Exclusion criteria were chromosomal rearrangements, 22q11.2 microdeletion and/or extra-cardiac malformations (n = 64). We included cases with additional minor anomalies (n = 39), such as single umbilical artery. In 54 of 136 eligible cases, stored material was available for array analysis. CNVs were categorized as either (likely) benign, (likely) pathogenic or of unknown significance. In 18 of the 54 isolated left-sided CHDs we found 28 rare CNVs (prevalence 33%, average 1.6 CNV per person, size 10.6 kb-2.2 Mb). Our interpretation yielded clinically significant CNVs in two of 54 cases (4%) and variants of unknown significance in three other cases (6%). In left-sided CHDs that appear isolated, with normal chromosome analysis and 22q11.2 FISH analysis, array analysis detects clinically significant CNVs. When counselling parents of a fetus with a left-sided CHD it must be taken into consideration that aside from the cardiac characteristics, the presence of extra-cardiac malformations and chromosomal abnormalities influence the treatment plan and prognosis. © 2015 John Wiley & Sons, Ltd.

  6. Is there any relationship between low PAPP-A levels and measures of umbilical vein and placental thickness during first trimester of pregnancy?

    PubMed

    Uysal, Gulsum; Tutus, Sadan; Cagli, Fulya; Adiguzel, Cevdet

    2017-01-01

    Low pregnancy-associated plasma protein A (PAPP-A) level is associated with adverse perinatal outcomes. The purpose of this study was to evaluate relationship between umbilical cord diameter (UCD), umbilical vein and artery diameters (UVD, UAD), placental thickness, and PAPP-A level at gestational age of between 11 and 14 weeks. UCD, UVD, UAD, and placental thickness of 246 women were assessed during ultrasound examination at between 11 and 14 weeks of gestation, as well as measurement of nuchal translucency (NT) and crown-rump length (CRL). Patients were divided into 2 groups according to PAPP-A percentile. Group 1 comprised 23 patients who had low PAPP-A (<0.44 multiple of medians [MoM], <10 th percentile) and Group 2 was made up of 223 patients with PAPP-A of >0.44 MoM, >10 th percentile. Calipers used for measurement were placed inner edge to inner edge of echogenic boundaries of the vessel. Largest sections of all vessels (UV and both arteries) were evaluated. Thickest part of the placenta was used for placental thickness measurement. Narrow UCD (<4.5±0.6 mm) was associated with low PAPP-A level (p=0.02). There was no significant difference in UVD, UAD, or placental thickness between groups. There was no significant difference in gestational age, CRL, or NT between groups. Fetal birth weight was significantly lower in Group 1 (p=0.03). Closer attention to women with low-risk, healthy pregnancies and low PAPP-A level in first trimester screening results is recommended. They should be routinely screened for background medical risk factors and umbilical cord morphology in first trimester scan.

  7. [Pathophysiological changes of umbilical vessels in intrauterine growth restriction].

    PubMed

    Jakó, Mária; Surányi, Andrea; Kaiser, László; Domokos, Dóra; Gáspár, Róbert; Bártfai, György

    2014-12-14

    The prevalence of intrauterine growth restriction is 4-5000/100,000 births, and they give the majority of perinatal morbidity. The aim of the authors was to compare the pathomorphologic data and vasoreactivity of umbilical vessels and placenta of small for date newborns to that of the normal pregnancies. Samples of the umbilical cord and placenta were divided into case and control groups. Two 10 cm long segments were cut of the umbilical cord at placental insertion. Tissue bath experiment was performed on umbilical vessels and pathomorphologic data were collected according to the Royal College of Pathologists' protocol. After the development of basal tone, oxytocin and desmopressin did not enhance the vascular contraction, but the pathomorphological and ultrasonographic data were significantly different in the two groups. The results indicate that umbilical vessels might not have oxytocin or vasopressin receptors. The pathomorphologic and flowmetric differences could be the causes of small birth weight.

  8. Association between Hypoxia and Perinatal Arterial Ischemic Stroke: A Meta-Analysis

    PubMed Central

    Qu, Yi; Wu, Jinlin; Li, Xihong; Mu, Dezhi

    2014-01-01

    Background Perinatal arterial ischemic stroke (AIS) occurs in an estimated 17 to 93 per 100000 live births, yet the etiology is poorly understood. Although investigators have implicated hypoxia as a potential cause of AIS, the role of hypoxia in AIS remains controversial. The aim of this study was to estimate the association between perinatal hypoxia factors and perinatal arterial ischemic stroke through a meta-analysis of published observational studies. Patients and methods A systematic search of electronically available studies published through July 2013 was conducted. Publication bias and heterogeneity across studies were evaluated and summary odds ratios (ORs) and 95% confidence intervals (CIs) were calculated with fixed-effects or random-effects models. Results A total of 8 studies describing the association between perinatal hypoxia factors and neonatal arterial ischemic stroke (AIS) met inclusion criteria, and 550 newborns with AIS were enrolled. The associations were found for AIS: preeclampsia (OR 2.14; 95% CI, 1.25 to 3.66), ventouse delivery (OR 2.23; 95% CI, 1.26 to 3.97), fetal heart rate abnormalities (OR 6.30; 95% CI, 3.84 to 10.34), reduced fetal movement (OR 5.35; 95% CI, 2.17 to 13.23), meconium-stained liquor (OR 3.05; 95% CI, 2.02 to 4.60), low Apgar score (OR 5.77; 95% CI, 1.66 to 20.04) and resuscitation at birth (OR 4.59; 95% CI, 3.23 to 6.52). Our data did not show any significant change of the mean risk estimate for oxytocin induction (OR 1.33; 95% CI, 0.84 to 2.11) and low arterial umbilical cord ph (OR 4.63; 95% CI 2.14 to 9.98). Conclusions There is a significant association between perinatal hypoxia factors and AIS. The result indicates that perinatal hypoxia maybe one of causes of AIS. Large scale prospective clinical studies are still warranted. PMID:24587227

  9. Core Stage Inter-Tank Umbilical (CSITU) Lift at ML

    NASA Image and Video Library

    2017-10-11

    A heavy-lift crane and rigging are used to lift the Core Stage Inter-tank Umbilical (CSITU) up to about the 140-foot level of the mobile launcher (ML) tower at NASA's Kennedy Space Center in Florida. The CSITU is moved into place for a fit check of the attachment hardware. The umbilical will then be lowered down and installed permanently on the ML at a later date. The CSITU is a swing-arm umbilical that will connect to the Space Launch System core stage inter-tank. It will provide conditioned air, pressurized gases and power and data connection to the core stage. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  10. Abnormal stress echocardiography findings in cardiac amyloidosis.

    PubMed

    Ong, Kevin C; Askew, J Wells; Dispenzieri, Angela; Maleszewski, Joseph J; Klarich, Kyle W; Anavekar, Nandan S; Mulvagh, Sharon L; Grogan, Martha

    2016-06-01

    Cardiac involvement in immunoglobulin light chain (amyloid light chain, AL) amyloidosis is characterized by myocardial interstitial deposition but can also cause obstructive deposits in the coronary microvasculature. We retrospectively identified 20 patients who underwent stress echocardiography within 1 year prior to the histologic diagnosis of AL amyloidosis. Only patients with cardiac amyloidosis and no known obstructive coronary disease were included. Stress echocardiograms (13 exercise; 7 dobutamine) were performed for evaluation of dyspnea and/or chest pain. Stress-induced wall motion abnormalities (WMAs) occurred in 11 patients (55%), 4 of whom had normal left ventricular wall thickness. Coronary angiogram was performed in 9 of 11 patients and demonstrated no or mild epicardial coronary artery disease. Seven (54%) patients had an abnormal exercise blood pressure which occurred with similar likelihood between those with and without stress-induced WMAs. Stress-induced WMAs and abnormal exercise blood pressure may occur in patients with cardiac AL amyloidosis despite the absence of significant epicardial coronary artery disease. This finding should raise the possibility of cardiac amyloidosis even in the absence of significant myocardial thickening.

  11. [Umbilical endometriosis mimicking a keloid in a young black woman: A case report].

    PubMed

    Kourouma, H-S; Ecra, E-J; Allou, A-S; Kouyaté, M; Kouassi, Y-I; Kaloga, M; Kouassi, K-A; Kassi, K; Kouamé, K; Ahogo, C; Gbery, I-P; Sangaré, A

    2017-10-01

    Most umbilical tumors are diagnosed as benign tumors, umbilical metastases of abdominal and pelvic tumors, or Sister Marie Joseph nodule. Herein, we report a case of cutaneous umbilical endometriosis mistaken for a keloid. A young black woman aged 26 consulted for a painful umbilical tumefaction. She had noted the appearance of a nodule of the umbilicus 10 months ago with bleeding during her menstrual periods. Skin examination revealed a firm and painful umbilical nodule 2.5cm in diameter. She was treated with corticosteroid injections for one month for umbilical keloid. Given that the symptoms recurred regularly at the time of menstruation, we suspected umbilical endometriosis. This diagnosis was finally confirmed by histopathological examination and hormone therapy was instituted on gynecological advice before scheduled surgical excision. In a setting of an umbilical tumor simulating a keloid associated with cyclical symptoms in a black woman, the diagnosis of umbilical endometriosis should not be overlooked by the dermatologist. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  12. Umbilical cord blood: a guide for primary care physicians.

    PubMed

    Martin, Paul L; Kurtzberg, Joanne; Hesse, Brett

    2011-09-15

    Umbilical cord blood stem cell transplants are used to treat a variety of oncologic, genetic, hematologic, and immunodeficiency disorders. Physicians have an important role in educating, counseling, and offering umbilical cord blood donation and storage options to patients. Parents may donate their infant's cord blood to a public bank, pay to store it in a private bank, or have it discarded. The federal government and many state governments have passed laws and issued regulations regarding umbilical cord blood, and some states require physicians to discuss cord blood options with pregnant women. Five prominent medical organizations have published recommendations about cord blood donation and storage. Current guidelines recommend donation of umbilical cord blood to public banks when possible, or storage through the Related Donor Cord Blood Program when a sibling has a disease that may require a stem cell transplant. Experts do not currently recommend private banking for unidentified possible future use. Step-by-step guidance and electronic resources are available to physicians whose patients are considering saving or donating their infant's umbilical cord blood.

  13. Apoptosis in the Ovine Fetal Brain Following Placental Embolization and Intermittent Umbilical Cord Occlusion.

    PubMed

    Aksoy, Tuba; Richardson, Bryan S; Han, Victor K; Gagnon, Robert

    2016-02-01

    The purpose of this study was to compare the regional distribution of apoptotic cells in the near term ovine fetal brain caused by prolonged moderate hypoxia, as seen in placental insufficiency, and intermittent severe hypoxia, as seen in umbilical cord compression, which may then contribute to adverse neurodevelopment in the postnatal life. We hypothesized that apoptosis in the fetal brain will be increased in response to both prolonged moderate hypoxia and intermittent severe hypoxia. Twenty-one near term (126-127 days) sheep were divided into 3 groups: control (CON; n = 7), placental embolization (EMB; n = 7), and umbilical cord occlusion (UCO; n = 8). The EMB group had microsphere injections into the umbilical arterial circulation until the oxygen content was at 50% of baseline value. The UCO group had complete cord occlusion for 2 minutes every hour, 6 times a day for 2 consecutive days. At 4 pm on day 2, the animals were euthanized; fetal brains were fixed and prepared for apoptosis staining using the terminal uridine deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) assay method. In the cerebellar white matter, there was a 3-fold increase in the number of TUNEL positive cells per 1000 cells in both EMB and UCO animals as compared to CON (P = .017). There was also a significant increase in the frontal cortical grey matter (layers 1-3) in EMB animals as compared to CON (P = .014). As such, apoptosis in the near term fetal sheep brain is altered with both sustained moderate hypoxia and intermittent severe hypoxia in the latter part of pregnancy, with potential for long-term neurological sequelae. © The Author(s) 2015.

  14. An umbilical polyp in an infant.

    PubMed

    Swanson, David L; Pakzad, Betty

    2005-10-01

    The persistence at birth of the omphalomesenteric (vitelline) duct may result in life-threatening consequences. Early identification of this congenital anomaly is essential for prompt surgical treatment to eliminate the risk of prolapse and herniation. A neonatal umbilical polyp may indicate the presence of an omphalomesenteric duct remnant. We describe the diagnosis and surgical treatment of an infant with an umbilical polyp. We also present an overview of the diagnosis and treatment of vitelline duct remnants and their associated anomalies.

  15. Lesional perfusion abnormalities in Leigh disease demonstrated by arterial spin labeling correlate with disease activity.

    PubMed

    Whitehead, Matthew T; Lee, Bonmyong; Gropman, Andrea

    2016-08-01

    Leigh disease is a metabolic disorder of the mitochondrial respiratory chain culminating in symmetrical necrotizing lesions in the deep gray nuclei or brainstem. Apart from classic gliotic/necrotic lesions, small-vessel proliferation is also characteristic on histopathology. We have observed lesional hyperperfusion on arterial spin-labeling (ASL) sequence in children with Leigh disease. In this cross-sectional analysis, we evaluated lesional ASL perfusion characteristics in children with Leigh syndrome. We searched the imaging database from an academic children's hospital for "arterial spin labeling, perfusion, necrosis, lactate, and Leigh" to build a cohort of children for retrospective analysis. We reviewed each child's medical record to confirm a diagnosis of Leigh disease, excluding exams with artifact, technical limitations, and without ASL images. We evaluated the degree and extent of cerebral blood flow and relationship to brain lesions. Images were compared to normal exams from an aged-matche cohort. The database search yielded 45 exams; 30 were excluded. We evaluated 15 exams from 8 children with Leigh disease and 15 age-matched normal exams. In general, Leigh brain perfusion ranged from hyperintense (n=10) to hypointense (n=5). Necrotic lesions appeared hypointense/hypoperfused. Active lesions with associated restricted diffusion demonstrated hyperperfusion. ASL perfusion patterns differed significantly from those on age-matched normal studies (P=<.0001). Disease activity positively correlated with cerebral deep gray nuclei hyperperfusion (P=0.0037) and lesion grade (P=0.0256). Children with Leigh disease have abnormal perfusion of brain lesions. Hyperperfusion can be found in active brain lesions, possibly associated with small-vessel proliferation characteristic of the disease.

  16. Clinical utility of third-trimester uterine artery Doppler in the prediction of brain hemodynamic deterioration and adverse perinatal outcome in small-for-gestational-age fetuses.

    PubMed

    Cruz-Martinez, R; Savchev, S; Cruz-Lemini, M; Mendez, A; Gratacos, E; Figueras, F

    2015-03-01

    To assess the clinical value of third-trimester uterine artery (UtA) Doppler ultrasound in the prediction of hemodynamic deterioration and adverse perinatal outcome in term small-for-gestational-age (SGA) fetuses. UtA Doppler parameters, cerebroplacental ratio (CPR) and fetal middle cerebral artery (MCA) pulsatility index (PI) were evaluated weekly, starting from the time of SGA diagnosis until 24 h before induction of labor, in a cohort of 327 SGA fetuses with normal umbilical artery PI (< 95th centile), delivered at > 37 weeks' gestation. Differences in the sequence of CPR and MCA-PI changes < 5th centile, between the group with normal UtA Doppler indices at diagnosis and those with abnormal UtA indices, were analyzed by survival analysis. In addition, the use of UtA Doppler value, alone or in combination with a brain Doppler scan before delivery, to predict the risk of Cesarean section, Cesarean section for non-reassuring fetal status (NRFS), neonatal acidosis and neonatal hospitalization was evaluated by logistic regression analysis, adjusted for gestational age at birth and birth-weight percentile. Abnormal UtA Doppler at diagnosis of SGA was associated with a higher risk of developing abnormal brain Doppler indices before induction of labor than in those with a normal UtA at diagnosis (62.7% vs 34.6%, respectively; P < 0.01). Compared to those with normal UtA Doppler indices, those with abnormal UtA Doppler findings were associated with a higher risk of intrapartum Cesarean section (52.2% vs 37.3%, respectively; P = 0.03), Cesarean section for NRFS (35.8% vs 23.1%, respectively; P = 0.03), neonatal acidosis (10.4% vs 7.7%, respectively; P = 0.47) and neonatal hospitalization (23.9% vs 16.5%, respectively; P = 0.16). Logistic regression analysis indicated that UtA Doppler findings were not significantly associated with adverse perinatal outcome independent of brain Doppler findings. UtA Doppler indices predict adverse perinatal

  17. Deformation and Flexibility Equations for ARIS Umbilicals Idealized as Planar Elastica

    NASA Technical Reports Server (NTRS)

    Hampton, R. David; Leamy, Michael J.; Bryant, Paul J.; Quraishi, Naveed

    2005-01-01

    The International Space Station relies on the active rack isolation system (ARIS) as the central component of an integrated, stationwide strategy to isolate microgravity space-science experiments. ARIS uses electromechanical actuators to isolate an international standard payload rack from disturbances due to the motion of the Space Station. Disturbances to microgravity experiments on ARIS isolated racks are transmitted primarily via the ARIS power and vacuum umbilicals. Experimental tests indicate that these umbilicals resonate at frequencies outside the ARIS controller s bandwidth at levels of potential concern for certain microgravity experiments. Reduction in the umbilical resonant frequencies could help to address this issue. This work documents the development and verification of equations for the in-plane deflections and flexibilities of an idealized umbilical (thin, flexible, inextensible, cantilever beam) under end-point, in-plane loading (inclined-force and moment). The effect of gravity is neglected due to the on-orbit application. The analysis assumes an initially curved (not necessarily circular), cantilevered umbilical with uniform cross-section, which undergoes large deflections with no plastic deformation, such that the umbilical slope changes monotonically. The treatment is applicable to the ARIS power and vacuum umbilicals under the indicated assumptions.

  18. Insulin Restores Gestational Diabetes Mellitus–Reduced Adenosine Transport Involving Differential Expression of Insulin Receptor Isoforms in Human Umbilical Vein Endothelium

    PubMed Central

    Westermeier, Francisco; Salomón, Carlos; González, Marcelo; Puebla, Carlos; Guzmán-Gutiérrez, Enrique; Cifuentes, Fredi; Leiva, Andrea; Casanello, Paola; Sobrevia, Luis

    2011-01-01

    OBJECTIVE To determine whether insulin reverses gestational diabetes mellitus (GDM)–reduced expression and activity of human equilibrative nucleoside transporters 1 (hENT1) in human umbilical vein endothelium cells (HUVECs). RESEARCH DESIGN AND METHODS Primary cultured HUVECs from full-term normal (n = 44) and diet-treated GDM (n = 44) pregnancies were used. Insulin effect was assayed on hENT1 expression (protein, mRNA, SLC29A1 promoter activity) and activity (initial rates of adenosine transport) as well as endothelial nitric oxide (NO) synthase activity (serine1177 phosphorylation, l-citrulline formation). Adenosine concentration in culture medium and umbilical vein blood (high-performance liquid chromatography) as well as insulin receptor A and B expression (quantitative PCR) were determined. Reactivity of umbilical vein rings to adenosine and insulin was assayed by wire myography. Experiments were in the absence or presence of l-NG-nitro-l-arginine methyl ester (l-NAME; NO synthase inhibitor) or ZM-241385 (an A2A-adenosine receptor antagonist). RESULTS Umbilical vein blood adenosine concentration was higher, and the adenosine- and insulin-induced NO/endothelium-dependent umbilical vein relaxation was lower in GDM. Cells from GDM exhibited increased insulin receptor A isoform expression in addition to the reported NO–dependent inhibition of hENT1-adenosine transport and SLC29A1 reporter repression, and increased extracellular concentration of adenosine and NO synthase activity. Insulin reversed all these parameters to values in normal pregnancies, an effect blocked by ZM-241385 and l-NAME. CONCLUSIONS GDM and normal pregnancy HUVEC phenotypes are differentially responsive to insulin, a phenomenon where insulin acts as protecting factor for endothelial dysfunction characteristic of this syndrome. Abnormal adenosine plasma levels, and potentially A2A-adenosine receptors and insulin receptor A, will play crucial roles in this phenomenon in GDM. PMID:21515851

  19. Insulin restores gestational diabetes mellitus-reduced adenosine transport involving differential expression of insulin receptor isoforms in human umbilical vein endothelium.

    PubMed

    Westermeier, Francisco; Salomón, Carlos; González, Marcelo; Puebla, Carlos; Guzmán-Gutiérrez, Enrique; Cifuentes, Fredi; Leiva, Andrea; Casanello, Paola; Sobrevia, Luis

    2011-06-01

    To determine whether insulin reverses gestational diabetes mellitus (GDM)-reduced expression and activity of human equilibrative nucleoside transporters 1 (hENT1) in human umbilical vein endothelium cells (HUVECs). Primary cultured HUVECs from full-term normal (n = 44) and diet-treated GDM (n = 44) pregnancies were used. Insulin effect was assayed on hENT1 expression (protein, mRNA, SLC29A1 promoter activity) and activity (initial rates of adenosine transport) as well as endothelial nitric oxide (NO) synthase activity (serine(1177) phosphorylation, l-citrulline formation). Adenosine concentration in culture medium and umbilical vein blood (high-performance liquid chromatography) as well as insulin receptor A and B expression (quantitative PCR) were determined. Reactivity of umbilical vein rings to adenosine and insulin was assayed by wire myography. Experiments were in the absence or presence of l-N(G)-nitro-l-arginine methyl ester (l-NAME; NO synthase inhibitor) or ZM-241385 (an A(2A)-adenosine receptor antagonist). Umbilical vein blood adenosine concentration was higher, and the adenosine- and insulin-induced NO/endothelium-dependent umbilical vein relaxation was lower in GDM. Cells from GDM exhibited increased insulin receptor A isoform expression in addition to the reported NO-dependent inhibition of hENT1-adenosine transport and SLC29A1 reporter repression, and increased extracellular concentration of adenosine and NO synthase activity. Insulin reversed all these parameters to values in normal pregnancies, an effect blocked by ZM-241385 and l-NAME. GDM and normal pregnancy HUVEC phenotypes are differentially responsive to insulin, a phenomenon where insulin acts as protecting factor for endothelial dysfunction characteristic of this syndrome. Abnormal adenosine plasma levels, and potentially A(2A)-adenosine receptors and insulin receptor A, will play crucial roles in this phenomenon in GDM.

  20. Laparoscopic uterine artery occlusion for symptomatic leiomyomas.

    PubMed

    Lichtinger, Moises; Hallson, Laurey; Calvo, Patricia; Adeboyejo, Ghea

    2002-05-01

    To describe a laparoscopic technique that safely occludes both uterine arteries, overcoming an altered surgical field resulting from scarring and/or uterine leiomyomatous growth. Prospective analysis (Canadian Task Force classification II-2). Nonprofit community hospital. Eight women with leiomyomas with abnormal uterine bleeding, pelvic pain or pressure, and/or anemia. Bilateral laparoscopic retroperitoneal uterine artery occlusion. Occlusion at the initial track of the uterine artery was performed by laparoscopic coated ligature in six patients. In two obese patients with deep retroperitoneal space, vascular clips were placed endoscopically using the same dissecting technique. All patients were discharged within 20 hours after the procedure. All five women with abnormal bleeding reported satisfactory decrease; none reported amenorrhea. Of eight with preoperative pain or pressure, seven reported complete disappearance and one significant relief. All three patients with anemia had normal red cell counts after 1 month. Laparoscopic uterine artery occlusion using a lateral retroperitoneal technique is safe and effective in women with pelvic scarring and altered pelvic anatomy.

  1. Diagnostic Value of Transthoracic Echocardiography in Patients With Anomalous Origin of the Left Coronary Artery From the Pulmonary Artery

    PubMed Central

    Li, Rong-Juan; Sun, Zhonghua; Yang, Jiao; Yang, Ya; Li, Yi-Jia; Leng, Zhao-Ting; Liu, Guo-Wen; Pu, Li-Hong

    2016-01-01

    Abstract Anomalous origin of the left coronary artery from the pulmonary artery (ALCAPA) is a rare congenital coronary abnormality associated with early infant mortality and sudden death in adults. Transthoracic echocardiography (TTE) plays an important role in early detection and diagnosis of ALCAPA as a noninvasive modality. However, its diagnostic value is not well studied. The purpose of this study is to determine the performance of TTE in the diagnostic assessment of ALCAPA as compared with coronary CT and invasive coronary angiography. A total of 22 patients (13 women and 9 men, mean age, 12.9 ± 19.5 years) with ALCAPA who underwent echocardiographic examination for clinical diagnosis were retrospectively reviewed and analyzed. Transthoracic echocardiographic features of ALCAPA were analyzed and its diagnostic value was compared with invasive coronary angiography and coronary CT angiography (CTA) with surgical findings serving as the gold standard. Surgery was performed in all of the patients to establish the dual coronary artery system. Five underwent the Takeuchi procedure and 17 had re-implantation of the anomalous left coronary artery. Of 20 patients, echocardiographic diagnoses were in good agreement with findings at surgery, resulting in the diagnostic accuracy of 90.9%. Two cases were misdiagnosed—one as the right coronary artery to pulmonary artery fistula and the other as rheumatic heart disease. The echocardiographic features of these patients with ALCAPA included: abnormal left coronary ostium arising from the pulmonary trunk with retrograde coronary artery flow in 20 patients; enlargement of the right coronary artery in 17 patients; abundant intercoronary septal collaterals in 17 patients; and moderate and significant mitral regurgitation in 14 patients. The diagnostic accuracy of invasive coronary angiography (in 17 patients) and coronary CTA (in 9 patients) was 100%. This study shows that TTE is an accurate, noninvasive imaging modality

  2. An ovary as unusual contents of an incarcerated umbilical hernia.

    PubMed

    Ahmed, U; Ahmed, R; Kamat, S; Elkholy, K

    2014-09-01

    We present the unusual case of a woman presenting with an incarcerated umbilical hernia. Intraoperatively, the contents of the hernia were found to be an ovary. We outline the clinical presentation of our patient, investigations and management as well as a discussion on unusual contents of umbilical hernias. To our knowledge, this is the first case of a non-malignant ovary incarcerated in an umbilical hernia.

  3. Intrauterine growth restriction is associated with structural alterations in human umbilical cord and decreased nitric oxide-induced relaxation of umbilical vein.

    PubMed

    Peyter, A-C; Delhaes, F; Baud, D; Vial, Y; Diaceri, G; Menétrey, S; Hohlfeld, P; Tolsa, J-F

    2014-11-01

    Intrauterine growth restriction (IUGR) affects ∼8% of all pregnancies and is associated with major perinatal mortality and morbidity, and with an increased risk to develop cardiovascular diseases in adulthood. Despite identification of several risk factors, the mechanisms implicated in the development of IUGR remain poorly understood. In case of placental insufficiency, reduced delivery of oxygen and/or nutrients to the fetus could be associated with alterations in the umbilical circulation, contributing further to the impairment of maternal-fetal exchanges. We compared the structural and functional properties of umbilical cords from growth-restricted and appropriate for gestational age (AGA) term newborns, with particular attention to the umbilical vein (UV). Human umbilical cords were collected at delivery. Morphological changes were investigated by histomorphometry, and UV's reactivity by pharmacological studies. Growth-restricted newborns displayed significantly lower growth parameters, placental weight and umbilical cord diameter than AGA controls. Total cross-section and smooth muscle areas were significantly smaller in UV of growth-restricted neonates than in controls. Maximal vasoconstriction achieved in isolated UV was lower in growth-restricted boys than in controls, whereas nitric oxide-induced relaxation was significantly reduced in UV of growth-restricted girls compared to controls. IUGR is associated with structural alterations of the UV in both genders, and with a decreased nitric oxide-induced relaxation in UV of newborn girls, whereas boys display impaired vasoconstriction. Further investigations will allow to better understand the regulation of umbilical circulation in growth-restricted neonates, which could contribute to devise potential novel therapeutic strategies to prevent or limit the development of IUGR. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Early embryonic demise: no evidence of abnormal spiral artery transformation or trophoblast invasion.

    PubMed

    Ball, E; Robson, S C; Ayis, S; Lyall, F; Bulmer, J N

    2006-03-01

    Invasion by extravillous trophoblast of uterine decidua and myometrium and the associated spiral artery 'transformation' are essential for the development of normal pregnancy. Small pilot studies of placental bed and basal plate tissues from miscarriages have suggested that impaired interstitial and endovascular trophoblast invasion may play a role in the pathogenesis of miscarriage. The hypothesis that early miscarriage is associated with reduced extravillous trophoblast invasion and spiral artery transformation was tested in a large series of placental bed biopsies containing decidua and myometrium and at least one spiral artery from early, karyotyped embryonic miscarriages (artery medial smooth muscle (desmin), and endothelium (von Willebrand factor). Trophoblast invasion and individual features of spiral artery transformation were assessed histologically in spiral arteries of miscarriages (n = 176) and controls (n = 246) and analysed statistically using a logistic regression model. Trophoblast invasion of uterine tissues and spiral artery transformation did not differ between euploid and aneuploid early miscarriage and also did not differ significantly from normal pregnancy. These findings suggest that failed trophoblast invasion and spiral artery transformation do not have a pivotal role in the pathogenesis of early miscarriage.

  5. An ovary as unusual contents of an incarcerated umbilical hernia

    PubMed Central

    Ahmed, R; Kamat, S; Elkholy, K

    2014-01-01

    We present the unusual case of a woman presenting with an incarcerated umbilical hernia. Intraoperatively, the contents of the hernia were found to be an ovary. We outline the clinical presentation of our patient, investigations and management as well as a discussion on unusual contents of umbilical hernias. To our knowledge, this is the first case of a non-malignant ovary incarcerated in an umbilical hernia. PMID:25198958

  6. Core Stage Forward Skirt Umbilical Installation onto Mobile Laun

    NASA Image and Video Library

    2017-05-25

    Construction workers assist as a crane lifts the Core Stage Forward Skirt Umbilical up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System (SLS) rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The CSFSU will be located at about the 180-foot level on the tower, above the liquid oxygen tank. The CSFSU is an umbilical that will swing into position to provide connections to the core stage forward skirt of the SLS rocket, and then swing away before launch. Its main purpose is to provide conditioned air/GN2 to the SLS core stage forward skirt cavity. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  7. Core Stage Forward Skirt Umbilical Installation onto Mobile Laun

    NASA Image and Video Library

    2017-05-25

    A crane has been attached to the Core Stage Forward Skirt Umbilical (CSFSU) to lift it up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System (SLS) rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The CSFSU will be located at about the 180-foot level on the tower, above the liquid oxygen tank. The CSFSU is an umbilical that will swing into position to provide connections to the core stage forward skirt of the SLS rocket, and then swing away before launch. Its main purpose is to provide conditioned air/GN2 to the SLS core stage forward skirt cavity. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  8. Core Stage Forward Skirt Umbilical Installation onto Mobile Laun

    NASA Image and Video Library

    2017-05-25

    Cranes and rigging are being used to lift up the Core Stage Forward Skirt Umbilical (CSFSU) for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System (SLS) rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The CSFSU will be located at about the 180-foot level on the tower, above the liquid oxygen tank. The CSFSU is an umbilical that will swing into position to provide connections to the core stage forward skirt of the SLS rocket, and then swing away before launch. Its main purpose is to provide conditioned air/GN2 to the SLS core stage forward skirt cavity. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  9. Core Stage Forward Skirt Umbilical Installation onto Mobile Laun

    NASA Image and Video Library

    2017-05-25

    Cranes and rigging are being used to lift the Core Stage Forward Skirt Umbilical (CSFSU) into position for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System (SLS) rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The CSFSU will be located at about the 180-foot level on the tower, above the liquid oxygen tank. The CSFSU is an umbilical that will swing into position to provide connections to the core stage forward skirt of the SLS rocket, and then swing away before launch. Its main purpose is to provide conditioned air/GN2 to the SLS core stage forward skirt cavity. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  10. Core Stage Forward Skirt Umbilical Installation onto Mobile Laun

    NASA Image and Video Library

    2017-05-25

    A construction worker welds a metal part during installation of the Core Stage Forward Skirt Umbilical on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System (SLS) rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The CSFSU will be located at about the 180-foot level on the tower, above the liquid oxygen tank. The CSFSU is an umbilical that will swing into position to provide connections to the core stage forward skirt of the SLS rocket, and then swing away before launch. Its main purpose is to provide conditioned air/GN2 to the SLS core stage forward skirt cavity. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  11. Core Stage Forward Skirt Umbilical Installation onto Mobile Laun

    NASA Image and Video Library

    2017-05-25

    Construction workers assist as a crane lifts the Core Stage Forward Skirt Umbilical into position for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System (SLS) rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The CSFSU will be located at about the 180-foot level on the tower, above the liquid oxygen tank. The CSFSU is an umbilical that will swing into position to provide connections to the core stage forward skirt of the SLS rocket, and then swing away before launch. Its main purpose is to provide conditioned air/GN2 to the SLS core stage forward skirt cavity. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  12. Core Stage Forward Skirt Umbilical Installation onto Mobile Laun

    NASA Image and Video Library

    2017-05-25

    Seeming to hang in midair, the Core Stage Forward Skirt Umbilical (CSFSU) is lifted high up by crane for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The CSFSU will be located at about the 180-foot level on the tower, above the liquid oxygen tank. The CSFSU is an umbilical that will swing into position to provide connections to the core stage forward skirt of the SLS rocket, and then swing away before launch. Its main purpose is to provide conditioned air/GN2 to the SLS core stage forward skirt cavity. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  13. [The state of carotid arteries in young men with arterial hypertension].

    PubMed

    Safarova, A F; Iurtaeva, V R; Kotovskaia, Iu V; Kobalava, Zh D

    2012-01-01

    To study elastic properties of carotid arteries in young men with arterial hypertension (AH). We examined men aged 18-25 years (mean 21.1+/-0.14 years): 36 with normal blood pressure (BP), 123 with stable and 51 with unstable AH. Parameters studied comprised intima-media thickness (IMT) of carotid arteries, their M-mode measured maximal systolic and minimal diastolic diameters (Ds and Dd), stiffness of common carotid artery (CCA) wall determined on the basis of analysis of elasticity and distensibility coefficients (CC and DC), Peterson's and Young's modules of elasticity (Ep and E), and index of flow deformation (CS). Compared with young men with normal BP and unstable AH patients with stable AH had abnormal elastic properties of CCA and increased IMT. Stable AH in young men is associated with signs of remodeling of CCA walls and increase of their rigidity.

  14. A chicken embryo model for the study of umbilical and supraumbilical body wall malformations.

    PubMed

    Ridderbusch, Ina; Bergholz, Robert; Fattouh, Miriam; Eschenburg, Georg; Roth, Beate; Appl, Birgit; Maenner, Joerg; Reinshagen, Konrad; Kluth, Dietrich

    2015-06-01

    BACKGROUND/PURPOSE; The embryology of ventral body wall malformations is only partially understood, although their incidence is relatively common. As only few experimental data exist on the development of those defects, the aim of our study was to compare the teratogenic effect of trypan blue (TB) and suramin (SA) in their capability to induce umbilical and supraumbilical abdominal wall malformations in a chicken egg model. A total of 255 fertilized chicken eggs were incubated at 38 °C and 75% relative humidity. Embryos were treated in ovo on incubation day 2.5 (Hamburger/Hamilton (HH) stage 13). The eggshell was windowed, and solutions of TB or SA were injected into the coelomic cavity at the region of the umbilicus. The window was closed and the embryos reincubated until examination on day 8 (HH 34). A total of 60 embryos survived in each group. The largest number of embryos presented with defects in the umbilical and supraumbilical region (25% in the SA group and 40% in the TB group). A combination of both defects (thoracoabdominoschisis) was seen in 20% of the TB and 8.3% of the SA groups, respectively. Associated anomalies found in both groups were head and eye defects, abnormal pelvic configurations, leg deformities, and mild forms of cloacal exstrophies. TB and SA have both a high potential to induce umbilical and supraumbilical ventral body wall malformations in chicken embryos. This novel animal model might help to establish a more profound understanding of the developmental steps in ventral body wall formation and the embryology for its malformations. Georg Thieme Verlag KG Stuttgart · New York.

  15. Prevalence and pattern of abnormal myocardial perfusion in patients with isolated coronary artery ectasia: study by 99mTc-sestamibi radionuclide scintigraphy.

    PubMed

    Ismail, Ahmed M; Rayan, Mona; Adel, Amr; Demerdash, Salah; Atef, Mohamed; Abdallah, Mohamed; Nammas, Wail

    2014-02-01

    We explored the prevalence and pattern of abnormal myocardial perfusion in patients with isolated coronary artery ectasia (CAE), as demonstrated by (99m)Tc-sestamibi scintigraphy. Prospectively, we enrolled 35 patients with angiographically documented CAE and no significant coronary obstruction, who underwent elective coronary angiography. Patients underwent Stress-rest (99m)Tc-sestamibi scintigraphy within 4 days of coronary angiography. They were divided into 2 groups: group I: with normal perfusion scan; and group II: with reversible perfusion defects. The mean age was 49.6 ± 6.9 years; 34 (97.1 %) were males. Seventy-nine (75.2 %) arteries were affected by CAE. Among 79 arteries affected by CAE, affection was diffuse in 37 (46.8 %). Thirteen (37.1 %) patients had normal perfusion scan (group I), whereas 22 (62.9 %) had reversible perfusion defects (group II). Among 22 patients with reversible perfusion defects, 20 (90.9 %) had mild and 2 (9.1 %) had moderate ischemia. Among 49 myocardial segments with reversible perfusion defects, 22 (44.9 %) were basal, 18 (36.7 %) mid-, and 9 (18.4 %) apical segments. Diffuse CAE was significantly more prevalent in group II versus group I, in all 3 major coronary arteries (p < 0.05 for all). In patients with isolated CAE who underwent elective coronary angiography, reversible perfusion defects demonstrated by (99m)Tc-sestamibi scintigraphy were rather prevalent, mostly mild, more likely to affect the basal and mid-segments of the myocardium, and more frequently associated with diffuse ectasia.

  16. Alimentazione del neonato pretermine IUGR: studio multicentrico ADEPT (Abnormal Doppler Enteral Prescription Trial). (Feeding the IUGR premature newborn infant: the multicenter ADEPT study).

    PubMed

    Leaf, A

    2010-06-01

    Pregnancies complicated by abnormal antenatal Doppler blood flow often result in the preterm delivery of a growth restricted baby. These babies have a high risk of milk intolerance and necrotising enterocolitis (1), and introduction of milk feeds is frequently delayed. Our aim was to determine the effect of early or late introduction on success of achieving full milk feeds and on adverse outcomes including NEC. Eligible babies with birthweight below 10th centile and gestation below 34+6 weeks, born after abnormal antenatal Dopplers, were randomised between 20 and 48 hours to either early (24-48 hours) or late (120-144 hours) introduction of milk feeds. Babies with major congenital anomaly, in-utero transfusion, multi-organ failure or need for inotropes were excluded. Feed volumes and rate of increase were standardised, and were the same for both groups. Daily feed logs were kept. 404 babies were randomised from 56 units in U.K. and Ireland (202 in each group). There were no important differences between groups at randomisation. growth restricted preterm infants born after absent or reversed end-diastolic flow in the umbilical artery who are fed from the second day after birth achieve full feeds faster than those commencing feeds on day six. No difference was been seen in the incidence of NEC, in preliminary analysis. Final data analysis is currently being completed and will be presented at the conference.

  17. The umbilical and paraumbilical veins of man.

    PubMed

    Martin, B F; Tudor, R G

    1980-03-01

    During its transit through the umbilicus structural changes occur in the thick wall of the extra-abdominal segment of the umbilical vein whereby the components of the intra-abdominal segment acquire an essentially longitudinal direction and become arranged in fibro-elastic and fibro-muscular zones. The vein lumen becomes largely obliterated by asymmetrical proliferation of loose subendothelial conective tissue. The latter forms a new inner zone within which a small segment of the lumen persists in an eccentric position. This residual lumen transmits blood to the portal system from paraumbilical and systemic sources, and is retained in the upper part of the vein, even in old age. A similar process of lumen closure is observed in the ductus venosus. In early childhood the lower third of the vein undergoes breakdown, with fatty infiltration, resulting in its complete division into vascular fibro-elastic strands, and in old age some breakdown occurs in the outermost part of the wall of the upper two thirds. The paraumbilical veins are thick-walled and of similar structure to the umbilical vein. Together they constitute an accessory portal system which is confined between the layers of the falciform ligament and is in communication with the veins of the ventral abdominal wall. The constituents form an ascending series, namely, Burow's veins, the umbilical vein, and Sappey's inferior and superior veins. The main channel of Sappey's inferior veins may be the remnant of the right umbilical vein since it communicates with the right rectus sheath and often communicates directly with the portal system within the right lobe of the liver. The results are of significance in relation to clinical usage of the umbilical vein.

  18. ACOG committee opinion number 399, February 2008: umbilical cord blood banking.

    PubMed

    2008-02-01

    Two types of banks have emerged for the collection and storage of umbilical cord blood--public banks and private banks. Public banks promote allogenic (related or unrelated) donation, analogous to the current collection of whole blood units in the United States. Private banks were initially developed to store stem cells from umbilical cord blood for autologous use (taken from an individual for subsequent use by the same individual) by a child if the child develops disease later in life. If a patient requests information on umbilical cord blood banking, balanced and accurate information regarding the advantages and disadvantages of public versus private banking should be provided. The remote chance of an autologous unit of umbilical cord blood being used for a child or a family member (approximately 1 in 2,700 individuals) should be disclosed. The collection should not alter routine practice for the timing of umbilical cord clamping. Physicians or other professionals who recruit pregnant women and their families for for-profit umbilical cord blood banking should disclose any financial interests or other potential conflicts of interest.

  19. Umbilical Cord Blood: Information for Childbirth Educators

    PubMed Central

    Waller-Wise, Renece

    2011-01-01

    Umbilical cord blood was once thought of as a waste product. Now, years after the first successful umbilical cord blood transplant, more families seek information about whether or not to save their newborn’s cord blood. Childbirth educators may be one of the main sources that an expectant family depends on to gain more knowledge about cord blood banking in order to make an informed decision. Preserving umbilical cord blood in public banks is advisable for any family; however, it is recommended that expectant families only consider private cord blood banking when they have a relative with a known disorder that is treatable by stem cell transplants. The childbirth educator is encouraged to be well versed on the topic of cord blood banking, so that as questions from class participants arise, the topic can be explored and addressed appropriately. PMID:22211060

  20. Central Arterial Function Measured by Non-invasive Pulse Wave Analysis is Abnormal in Patients with Duchenne Muscular Dystrophy.

    PubMed

    Ryan, Thomas D; Parent, John J; Gao, Zhiqian; Khoury, Philip R; Dupont, Elizabeth; Smith, Jennifer N; Wong, Brenda; Urbina, Elaine M; Jefferies, John L

    2017-08-01

    Duchenne muscular dystrophy (DMD) is an X-linked recessive disorder caused by mutation of dystrophin. Cardiovascular involvement includes dilated cardiomyopathy. Non-invasive assessment of vascular function has not been evaluated in DMD. We hypothesize arterial wave reflection is abnormal in patients with DMD. Pulse wave analysis was performed on DMD patients with a SphygmoCor SCOR-PVx System to determine central blood pressure and augmentation index (AIx) as an assessment of arterial wave reflection. Results were compared to a control group. A total of 43 patients with DMD were enrolled, and compared to 43 normal controls. Central systolic blood pressure was lower, while both AIx-75 (7.8 ± 9.6% vs. 2.1 ± 10.4%, p 0.01, DMD vs. normal) and AIx-not corrected (16.8 ± 10.1% vs. -3.6 ± 10.9, p < 0.001, DMD vs. normal) were higher in the DMD compared to control. Using multivariable linear regression model, the variables found to have a significant effect on AIx-not corrected included diagnosis of DMD, height, and heart rate (r 2  = 0.257). The current data suggest that, despite lower central systolic blood pressure, patients with DMD have higher wave reflection when compared to normal controls, which may represent increased arterial stiffness. Overall there appears to be no effect on ventricular systolic function, however the long-term consequence in this group is unknown. Further study is required to determine the mechanism of these differences, which may be related to the effects of systemic steroids or the role of dystrophin in vascular function.

  1. Predicting intrapartum fetal compromise using the fetal cerebro-umbilical ratio.

    PubMed

    Sabdia, S; Greer, R M; Prior, T; Kumar, S

    2015-05-01

    The aim of this study was to explore the association between the cerebro-umbilical ratio measured at 35-37 weeks and intrapartum fetal compromise. This retrospective cross sectional study was conducted at the Mater Mothers' Hospital in Brisbane, Australia. Maternal demographics and fetal Doppler indices at 35-37 weeks gestation for 1381 women were correlated with intrapartum and neonatal outcomes. Babies born by caesarean section or instrumental delivery for fetal compromise had the lowest median cerebro-umbilical ratio 1.60 (IQR 1.22-2.08) compared to all other delivery groups (vaginal delivery, emergency delivery for failure to progress, emergency caesarean section for other reasons or elective caesarean section). The percentage of infants with a cerebro-umbilical ratio <10th centile that required emergency delivery (caesarean section or instrumental delivery) for fetal compromise was 22%, whereas only 7.3% of infants with a cerebro-umbilical ratio between the 10th-90th centile and 9.6% of infants with a cerebro-umbilical ratio > 90th centile required delivery for the same indication (p < 0.001). A lower cerebro-umbilical ratio was associated with an increased risk of emergency delivery for fetal compromise, OR 2.03 (95% CI 1.41-2.92), p < 0.0001. This study suggests that a low fetal cerebro-umbilical ratio measured at 35-37 weeks is associated with a greater risk of intrapartum compromise. This is a relatively simple technique which could be used to risk stratify women in diverse healthcare settings. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Tail Service Mast Umbilical Arrival

    NASA Image and Video Library

    2016-08-02

    Technicians assist as a crane is used to lift the first Tail Service Mast Umbilical (TSMU) into the vertical position at the Launch Equipment Test Facility (LETF) at NASA’s Kennedy Space Center in Florida. Two TSMUs will provide liquid propellants and power to the Space Launch System (SLS) rocket’s core stage engine. Both TSMUs will connect to the zero-level deck on the mobile launcher, providing fuel and electricity to the SLS rocket before it launches on Exploration Mission 1. The TSMU will undergo testing and validation at the LETF to verify it is functioning properly. The center’s Engineering Directorate and the Ground Systems Development and Operations Program are overseeing processing and testing of the umbilicals.

  3. Tail Service Mast Umbilical Arrival

    NASA Image and Video Library

    2016-08-02

    A crane lowers the first Tail Service Mast Umbilical (TSMU) onto a test stand at the Launch Equipment Test Facility at NASA’s Kennedy Space Center in Florida. Two TSMUs will provide liquid propellants and power to the Space Launch System (SLS) rocket’s core stage engine. Both TSMUs will connect to the zero-level deck on the mobile launcher, providing fuel and electricity to the SLS rocket before it launches on Exploration Mission 1. The TSMU will undergo testing and validation at the LETF to verify it is functioning properly. The center’s Engineering Directorate and the Ground Systems Development and Operations Program are overseeing processing and testing of the umbilicals.

  4. Tail Service Mast Umbilical Arrival

    NASA Image and Video Library

    2016-08-02

    A crane is attached to the first Tail Service Mast Umbilical (TSMU) for NASA’s Space Launch System (SLS) at the Launch Equipment Test Facility at NASA’s Kennedy Space Center in Florida. Two TSMUs will provide liquid propellants and power to the Space Launch System (SLS) rocket’s core stage engine. Both TSMUs will connect to the zero-level deck on the mobile launcher, providing fuel and electricity to the SLS rocket before it launches on Exploration Mission 1. The TSMU will undergo testing and validation at the LETF to verify it is functioning properly. The center’s Engineering Directorate and the Ground Systems Development and Operations Program are overseeing processing and testing of the umbilicals.

  5. Tail Service Mast Umbilical Arrival

    NASA Image and Video Library

    2016-08-02

    A crane lifts the first Tail Service Mast Umbilical (TSMU) up for placement on a test stand at the Launch Equipment Test Facility at NASA’s Kennedy Space Center in Florida. Two TSMUs will provide liquid propellants and power to the Space Launch System (SLS) rocket’s core stage engine. Both TSMUs will connect to the zero-level deck on the mobile launcher, providing fuel and electricity to the SLS rocket before it launches on Exploration Mission 1. The TSMU will undergo testing and validation at the LETF to verify it is functioning properly. The center’s Engineering Directorate and the Ground Systems Development and Operations Program are overseeing processing and testing of the umbilicals.

  6. Tail Service Mast Umbilical Arrival

    NASA Image and Video Library

    2016-08-02

    Technician monitors the progress as a crane lowers the first Tail Service Mast Umbilical (TSMU) onto a test stand at the Launch Equipment Test Facility at NASA’s Kennedy Space Center in Florida. Two TSMUs will provide liquid propellants and power to the Space Launch System (SLS) rocket’s core stage engine. Both TSMUs will connect to the zero-level deck on the mobile launcher, providing fuel and electricity to the SLS rocket before it launches on Exploration Mission 1. The TSMU will undergo testing and validation at the LETF to verify it is functioning properly. The center’s Engineering Directorate and the Ground Systems Development and Operations Program are overseeing processing and testing of the umbilicals.

  7. Telomere length in the two extremes of abnormal fetal growth and the programming effect of maternal arterial hypertension.

    PubMed

    Tellechea, Mariana; Gianotti, Tomas Fernandéz; Alvariñas, Jorge; González, Claudio D; Sookoian, Silvia; Pirola, Carlos J

    2015-01-19

    We tested the hypothesis that leukocyte telomere length (LTL) is associated with birth weight in both extremes of abnormal fetal growth: small (SGA) and large for gestational age newborns (LGA). Clinical and laboratory variables of the mothers and the neonates were explored; 45 newborns with appropriate weight for gestational age (AGA), 12 SGA and 12 LGA were included. Whether the differences might be explained by variation in OBFC1 (rs9419958) and CTC1 (rs3027234) genes associated with LTL was determined. A significant association between birth weight and LTL was observed; LTL was significantly shorter in LGA newborns (1.01 ± 0.12) compared with SGA (1.73 ± 0.19) p < 0.005, mean ± SE. Maternal (Spearman R = -0.6, p = 0.03) and neonatal LTL (R = -0.25, p = 0.03) were significantly and inversely correlated with maternal history of arterial hypertension in previous gestations. Neonatal LTL was not significantly associated with either rs9419950 or rs3027234, suggesting that the association between neonatal LTL and birth weight is not influenced by genetic variation in genes that modify the interindividual LTL. In conclusion, telomere biology seems to be modulated by abnormal fetal growth; modifications in telomere length might be programmed by an adverse environment in utero.

  8. Hematogenous umbilical metastasis from colon cancer treated by palliative single-incision laparoscopic surgery

    PubMed Central

    Hori, Tomohide; Okada, Noriyuki; Nakauchi, Masaya; Hiramoto, Shuji; Kikuchi-Mizota, Ayako; Kyogoku, Masahisa; Oike, Fumitaka; Sugimoto, Hidemitsu; Tanaka, Junya; Morikami, Yoshiki; Shigemoto, Kaori; Ota, Toyotsugu; Kaneko, Masanobu; Nakatsuji, Masato; Okae, Shunji; Tanaka, Takahiro; Gunji, Daigo; Yoshioka, Akira

    2013-01-01

    Sister Mary Joseph’s nodule (SMJN) is a rare umbilical nodule that develops secondary to metastatic cancer. Primary malignancies are located in the abdomen or pelvis. Patients with SMJN have a poor prognosis. An 83-year-old woman presented to our hospital with a 1-month history of a rapidly enlarging umbilical mass. Endoscopic findings revealed advanced transverse colon cancer. computer tomography and fluorodeoxyglucose-positron emission tomography revealed tumors of the transverse colon, umbilicus, right inguinal lymph nodes, and left lung. The feeding arteries and drainage veins for the SMJN were the inferior epigastric vessels. Imaging findings of the left lung tumor allowed for identification of the primary lung cancer, and a diagnosis of advanced transverse colon cancer with SMJN and primary lung cancer was made. The patient underwent local resection of the SMNJ and subsequent single-site laparoscopic surgery involving right hemicolectomy and paracolic lymph node dissection. Intra-abdominal dissemination to the mesocolon was confirmed during surgery. Histopathologically, the transverse colon cancer was confirmed to be moderately differentiated tubular adenocarcinoma. We suspect that SMJN may occur via a hematogenous pathway. Although chemotherapy for colon cancer and thoracoscopic surgery for the primary lung cancer were scheduled, the patient and her family desired home hospice. Seven months after surgery, she died of rapidly growing lung cancer. PMID:24179626

  9. Primary extracranial vertebral artery aneurysms.

    PubMed

    Morasch, Mark D; Phade, Sachin V; Naughton, Peter; Garcia-Toca, Manuel; Escobar, Guillermo; Berguer, Ramon

    2013-05-01

    Extracranial vertebral artery aneurysms are uncommon and are usually associated with trauma or dissection. Primary cervical vertebral aneurysms are even rarer and are not well described. The presentation and natural history are unknown and operative management can be difficult. Accessing aneurysms at the skull base can be difficult and, because the frail arteries are often afflicted with connective tissue abnormalities, direct repair can be particularly challenging. We describe the presentation and surgical management of patients with primary extracranial vertebral artery aneurysms. In this study we performed a retrospective, multi-institutional review of patients with primary aneurysms within the extracranial vertebral artery. Between January 2000 and January 2011, 7 patients, aged 12-56 years, were noted to have 9 primary extracranial vertebral artery aneurysms. All had underlying connective tissue or another hereditary disorder, including Ehler-Danlos syndrome (n=3), Marfan's disease (n=2), neurofibromatosis (n=1), and an unspecified connective tissue abnormality (n=1). Eight of 9 aneurysms were managed operatively, including an attempted bypass that ultimately required vertebral ligation; the contralateral aneurysm on this patient has not been treated. Open interventions included vertebral bypass with vein, external carotid autograft, and vertebral transposition to the internal carotid artery. Special techniques were used for handling the anastomoses in patients with Ehler-Danlos syndrome. Although endovascular exclusion was not performed in isolation, 2 hybrid procedures were performed. There were no instances of perioperative stroke or death. Primary extracranial vertebral artery aneurysms are rare and occur in patients with hereditary disorders. Operative intervention is warranted in symptomatic patients. Exclusion and reconstruction may be performed with open and hybrid techniques with low morbidity and mortality. Copyright © 2013 Elsevier Inc. All rights

  10. Umbilical metastasis derived from early stage rectal cancer: a case report

    PubMed Central

    2014-01-01

    Background Umbilical metastasis, also called Sister Mary Joseph’s nodule (SMJN), is defined as the umbilical nodule associated with advanced metastatic intra-abdominal and pelvic malignancies. A patient with umbilical metastasis has been deemed to have a poor prognosis. Rectal cancer presenting with a SMJN is a rare phenomenon, especially in the early stage and in middle-low rectal cancer. Case presentation We report a case of a 70-year-old male presenting with umbilical metastasis derived from rectal cancer (10 cm from the anal verge, T2N0). Discussion and conclusion For rectal cancer with umbilical metastasis, the exact metastatic routes as well as the criterion of diagnosis and treatments are not very clear. Here we review the literature on rectal cancer and SMJN to deepen the understanding of this disease. PMID:24708697

  11. Deformation and Flexibility Equations for Idealized ARIS Umbilicals, Under Planar End-Loading Conditions

    NASA Technical Reports Server (NTRS)

    Hampton, R. David; Quraishi, Naveed (Technical Monitor)

    2003-01-01

    The International Space Station (ISS) relies on the Active Rack Isolation System (ARIS) as the central component of an integrated, station-wide strategy to isolate microgravity space-science experiments. ARIS uses electromechanical actuators to isolate an International Standard Payload Rack (ISPR) from disturbances due to the motion of the ISS. Disturbances to microgravity experiments on ARIS-isolated racks are primarily transmitted via the ARTS power and vacuum umbilicals. Recent experimental tests indicate that these umbilicals resonate at frequencies outside the ARIS controller's bandwidth, at levels of potential concern for certain microgravity experiments. Reduction in the umbilical resonant frequencies could help to address this issue. This report develops equations for the in-plane deflections and flexibilities of an idealized umbilical (thin, flexible, cantilever beam) under end-point, in-plane loading (inclined-force and moment). The effect of gravity is neglected due to the on-orbit application. The analysis assumes an initially straight, cantilevered umbilical with uniform cross-section, which undergoes large deflections with no plastic deformation, such that the umbilical terminus remains in a single quadrant and the umbilical slope changes monotonically. The analysis is applicable to the ARIS power and vacuum umbilicals, under the indicated assumptions.

  12. Deformation and Flexibility Equations for Idealized ARIS Umbilicals, Under Planar End-Loading Conditions

    NASA Technical Reports Server (NTRS)

    Hampton, R. David; Quraishi, Naveed; Rupert, Jason K.

    2000-01-01

    The International Space Station (ISS) relies on the Active Rack Isolation System (ARIS) as the central component of an integrated, station-wide strategy to isolate microgravity space-science experiments. ARIS uses electromechanical actuators to isolate an International Standard Payload Rack (ISPR) from disturbances due to the motion of the ISS. Disturbances to microgravity experiments on ARIS-isolated racks are primarily transmitted via the ARIS power and vacuum umbilicals. Recent experimental tests indicate that these umbilicals resonate at frequencies outside the ARIS controller's bandwidth. at levels of potential concern for certain microgravity experiments. Reduction in the umbilical resonant frequencies could help to address this issue. This paper develops equations for the in-plane deflections and flexibilities of an idealized umbilical (thin, flexible, cantilever beam) under end-point, in-plane loading (inclined-force and moment). The effect of gravity is neglected due to the on:orbit application. The analysis assumes an initially straight. cantilevered umbilical with uniform cross-section. which undergoes large deflections with no plastic deformation, such that the umbilical terminus remains in a single quadrant and the umbilical slope changes monotonically. The analysis is applicable to the ARIS power and vacuum umbilicals. under the indicated assumptions.

  13. Hepatectomy for metastatic liver tumors complicated with right umbilical portion.

    PubMed

    Sakaguchi, Takanori; Suzuki, Shohachi; Morita, Yoshifumi; Oishi, Kosuke; Suzuki, Atsushi; Fukumoto, Kazuhiko; Inaba, Keisuke; Takehara, Yasuo; Baba, Satoshi; Nakamura, Satoshi; Konno, Hiroyuki

    2011-01-01

    We report the case of a 76-year-old man, presenting with a right umbilical portion (RUP), with two liver metastases of rectal cancer, 2cm and 1 cm tumors in the caudate lobe and anterior segment, respectively. The portal first branch ran to the right posterior segment and the remaining formed a left trunk, thereafter forming RUP. The tumor in the caudate was close to the right posterior segment's Glissonean pedicle. On 3-dimensional CT analysis under tubography via an endoscopic naso-biliary tube, the anatomical patterns of the arteries and bile ducts were complicated. On laparotomy, the gallbladder was located to the left of the round ligament. Right posterior segmentectomy plus partial caudate resection and partial hepatectomy of the anterior segment was performed after skeletonization of the biliovascular structures at the hepatic hilum. Precise examination of the biliovascular structures is needed to safely perform hepatectomy in patients complicated with RUP.

  14. The Development and Implementation of the Kennedy Space Center Umbilical Clearance Tool

    NASA Technical Reports Server (NTRS)

    Chesnutt, David

    2016-01-01

    In preparation for NASAs upcoming Space Launch System program, the Kennedy Space Center is currently developing subsystems to provide fuel, purges and communications to the flight vehicle, known as umbilicals. It is vital to the crew and mission that these umbilicals release at T-0 without re-contacting the vehicle as it is accelerating from the launch pad. To help ensure this requirement is met by the program, a methodology of evaluating the moving bodies was developed and implemented into a tool using MATLAB. The tool, known as the KSC Umbilical Clearance Tool, takes a given elevation of interest and an umbilical retract profile within the plane to evaluate the clearance between the umbilical arm and thousands of independent flight vehicle drift profiles from a Monte Carlo analysis. The presentation will delve into the challenges associated with developing and implementing the tool framed in the context of evaluating the clearance for one of the SLS umbilicals.

  15. Poorly understood and often miscategorized congenital umbilical cord hernia: an alternative repair method.

    PubMed

    İnce, E; Temiz, A; Ezer, S S; Gezer, H Ö; Hiçsönmez, A

    2017-06-01

    Umbilical cord hernia is poorly understood and often miscategorized as "omphalocele minor". Careless clamping of the cord leads to iatrogenic gut injury in the situation of umbilical cord hernia. This study aimed to determine the characteristics and outcomes of umbilical cord hernias. We also highlight an alternative repair method for umbilical cord hernias. We recorded 15 cases of umbilical cord hernias over 10 years. The patients' data were retrospectively reviewed, and preoperative preparation of the newborn, gestational age, birth weight, other associated malformations, surgical technique used, enteral nutrition, and length of hospitalization were recorded. This study included 15 neonates with umbilical cord hernias. The mean gestational age at the time of referral was 38.2 ± 2.1 umbilical cord hernia, the body folds develop normally and form the umbilical ring. The double purse-string technique is easy to apply and produces satisfactory cosmetic results in neonates with umbilical cord hernias.

  16. Nutritional status and umbilical hernia in Nigerian school children of different ethnic groups.

    PubMed Central

    Ebomoyi, E.; Parakoyi, D. B.; Omonisi, M. K.

    1991-01-01

    The relationship between nutritional status and umbilical hernia was assessed among Hausa and Yoruba school children in rural areas of Kwara State, Nigeria. The prevalence of umbilical hernia in the rural school pupils was 19.4%. The Yoruba school children had a higher prevalence rate of 22.0%, while the prevalence rate for Hausa pupils was 16.9%. The association between umbilical hernia and primary school class was statistically significant. More school children suffering from protein energy malnutrition presented with umbilical hernia. The association between umbilical hernia and nutritional status was weak. The school health component of the national primary health program should be intensified to screen school children regularly for umbilical hernia. The school health environment of rural Nigerian schools should be improved through government efforts. Images Figure 1 Figure 2 PMID:1800766

  17. Tail Service Mast Umbilical Arrival

    NASA Image and Video Library

    2016-08-02

    A heavy-lift transport truck arrives at the Launch Equipment Test Facility (LETF) at NASA’s Kennedy Space Center in Florida, with the first of two Tail Service Mast Umbilicals (TSMU) for NASA’s Space Launch System (SLS). Two TSMUs will provide liquid propellants and power to the Space Launch System (SLS) rocket’s core stage engine. Both TSMUs will connect to the zero-level deck on the mobile launcher, providing fuel and electricity to the SLS rocket before it launches on Exploration Mission 1. The TSMU will undergo testing and validation at the LETF to verify it is functioning properly. The center’s Engineering Directorate and the Ground Systems Development and Operations Program are overseeing processing and testing of the umbilicals.

  18. Tail Service Mast Umbilical Arrival

    NASA Image and Video Library

    2016-08-02

    Technicians assist as a crane is used to lift the first Tail Service Mast Umbilical (TSMU) up from the flatbed of the transport truck at the Launch Equipment Test Facility (LETF) at NASA’s Kennedy Space Center in Florida. Two TSMUs will provide liquid propellants and power to the Space Launch System (SLS) rocket’s core stage engine. Both TSMUs will connect to the zero-level deck on the mobile launcher, providing fuel and electricity to the SLS rocket before it launches on Exploration Mission 1. The TSMU will undergo testing and validation at the LETF to verify it is functioning properly. The center’s Engineering Directorate and the Ground Systems Development and Operations Program are overseeing processing and testing of the umbilicals.

  19. Tail Service Mast Umbilical Arrival

    NASA Image and Video Library

    2016-08-02

    A crane is prepared to help lift the first Tail Service Mast Umbilical (TSMU) for NASA’s Space Launch System (SLS) at the Launch Equipment Test Facility (LETF) at NASA’s Kennedy Space Center in Florida. Two TSMUs will provide liquid propellants and power to the Space Launch System (SLS) rocket’s core stage engine. Both TSMUs will connect to the zero-level deck on the mobile launcher, providing fuel and electricity to the SLS rocket before it launches on Exploration Mission 1. The TSMU will undergo testing and validation at the LETF to verify it is functioning properly. The center’s Engineering Directorate and the Ground Systems Development and Operations Program are overseeing processing and testing of the umbilicals.

  20. Tail Service Mast Umbilical Arrival

    NASA Image and Video Library

    2016-08-02

    Technicians assist as a crane is used to lift the first Tail Service Mast Umbilical (TSMU) away from the flatbed of the transport truck at the Launch Equipment Test Facility (LETF) at NASA’s Kennedy Space Center in Florida. Two TSMUs will provide liquid propellants and power to the Space Launch System (SLS) rocket’s core stage engine. Both TSMUs will connect to the zero-level deck on the mobile launcher, providing fuel and electricity to the SLS rocket before it launches on Exploration Mission 1. The TSMU will undergo testing and validation at the LETF to verify it is functioning properly. The center’s Engineering Directorate and the Ground Systems Development and Operations Program are overseeing processing and testing of the umbilicals.

  1. Tail Service Mast Umbilical Arrival

    NASA Image and Video Library

    2016-08-02

    A technician monitors the progress as a crane lifts the first Tail Service Mast Umbilical (TSMU) for transfer to a test stand at the Launch Equipment Test Facility at NASA’s Kennedy Space Center in Florida. Two TSMUs will provide liquid propellants and power to the Space Launch System (SLS) rocket’s core stage engine. Both TSMUs will connect to the zero-level deck on the mobile launcher, providing fuel and electricity to the SLS rocket before it launches on Exploration Mission 1. The TSMU will undergo testing and validation at the LETF to verify it is functioning properly. The center’s Engineering Directorate and the Ground Systems Development and Operations Program are overseeing processing and testing of the umbilicals.

  2. The Upturned Superior Mesenteric Artery Sign for First-Trimester Detection of Congenital Diaphragmatic Hernia and Omphalocele.

    PubMed

    Lakshmy, Ravi Selvaraj; Agnees, Joy; Rose, Nity

    2017-03-01

    The aim of this study was to follow the course of the superior mesenteric artery (SMA) in first-trimester fetuses to predict the location of the small bowel. Its abnormal course aids in early detection of congenital diaphragmatic hernia (CDH) and assessment of the contents of omphalocele. The SMA can be easily identified in a sagittal section of the fetus by using color Doppler sonography at the 11- to 14-week scan, and normally, it has a downward course caudally to supply the intestines. The course of the SMA points to the location of the bowel. We report a series of 7 cases detected in first trimester with an abnormal course of the SMA, 3 of which had CDH and 4 of which had omphalocele. In CDH, the intestines herniate into the thoracic cavity; hence, the SMA tends to have an upward course toward the thorax. In 4 cases of omphalocele, the SMA follows the exteriorized bowel into the base of the umbilical cord. Second-trimester sonography for detection of congenital malformations is a standardized protocol, but a careful anatomic survey at the 11- to 14-week scan is often rewarding. When there is a suspicion of an intrathoracic mass or a mediastinal shift, the upturned course of SMA serves as a valuable sign in confirmation of CDH. Chromosomal abnormalities are often reported in cases of omphalocele containing small bowel only, and the upward course of the SMA toward the base of the cord helps in its early prenatal diagnosis, which facilitates early genetic assessment in these fetuses. © 2017 by the American Institute of Ultrasound in Medicine.

  3. Outcome in early-onset fetal growth restriction is best combining computerized fetal heart rate analysis with ductus venosus Doppler: insights from the Trial of Umbilical and Fetal Flow in Europe.

    PubMed

    Frusca, Tiziana; Todros, Tullia; Lees, Christoph; Bilardo, Caterina M

    2018-02-01

    Early-onset fetal growth restriction represents a particular dilemma in clinical management balancing the risk of iatrogenic prematurity with waiting for the fetus to gain more maturity, while being exposed to the risk of intrauterine death or the sequelae of acidosis. The Trial of Umbilical and Fetal Flow in Europe was a European, multicenter, randomized trial aimed to determine according to which criteria delivery should be triggered in early fetal growth restriction. We present the key findings of the primary and secondary analyses. Women with fetal abdominal circumference <10th percentile and umbilical pulsatility index >95th percentile between 26-32 weeks were randomized to 1 of 3 monitoring and delivery protocols. These were: fetal heart rate variability based on computerized cardiotocography; and early or late ductus venosus Doppler changes. A safety net based on fetal heart rate abnormalities or umbilical Doppler changes mandated delivery irrespective of randomized group. The primary outcome was normal neurodevelopmental outcome at 2 years. Among 511 women randomized, 362/503 (72%) had associated hypertensive conditions. In all, 463/503 (92%) of fetuses survived and cerebral palsy occurred in 6/443 (1%) with known outcome. Among all women there was no difference in outcome based on randomized group; however, of survivors, significantly more fetuses randomized to the late ductus venosus group had a normal outcome (133/144; 95%) than those randomized to computerized cardiotocography alone (111/131; 85%). In 118/310 (38%) of babies delivered <32 weeks, the indication was safety-net criteria: 55/106 (52%) in late ductus venosus, 37/99 (37%) in early ductus venosus, and 26/105 (25%) in computerized cardiotocography groups. Higher middle cerebral artery impedance adjusted for gestation was associated with neonatal survival without severe morbidity (odds ratio, 1.24; 95% confidence interval, 1.02-1.52) and infant survival without neurodevelopmental impairment at 2

  4. Umbilical Cord Care in the Newborn Infant.

    PubMed

    Stewart, Dan; Benitz, William

    2016-09-01

    Postpartum infections remain a leading cause of neonatal morbidity and mortality worldwide. A high percentage of these infections may stem from bacterial colonization of the umbilicus, because cord care practices vary in reflection of cultural traditions within communities and disparities in health care practices globally. After birth, the devitalized umbilical cord often proves to be an ideal substrate for bacterial growth and also provides direct access to the bloodstream of the neonate. Bacterial colonization of the cord not infrequently leads to omphalitis and associated thrombophlebitis, cellulitis, or necrotizing fasciitis. Various topical substances continue to be used for cord care around the world to mitigate the risk of serious infection. More recently, particularly in high-resource countries, the treatment paradigm has shifted toward dry umbilical cord care. This clinical report reviews the evidence underlying recommendations for care of the umbilical cord in different clinical settings. Copyright © 2016 by the American Academy of Pediatrics.

  5. Concomitant abdominoplasty and umbilical hernia repair using the Ventralex hernia patch.

    PubMed

    Neinstein, Ryan M; Matarasso, Alan; Abramson, David L

    2015-04-01

    Patients requesting abdominoplasty often have concomitant umbilical hernias and may request simultaneous treatment. The vascularity of the umbilicus is potentially at risk during these combined procedures. In this study, the authors present a technique for treating umbilical hernias at the time of abdominoplasty surgery using the Ventralex hernia patch. A total of 11 female patients with a mean age of 39.4 years (range, 28 to 51 years) undergoing abdominoplasty with umbilical hernia repair with the Ventralex patch were included. The mean body mass index was 27.6 kg/m (range, 20 to 34 kg/m). No vascular compromise of the umbilicus was seen. The hernia repair did not alter the abdominoplasty results. One patient had transient umbilical swelling postoperatively that resolved within 6 months postoperatively. The authors present a series of umbilical hernia repairs in abdominoplasty patients using a minimal access incision by means of the rectus fascia and the Ventralex patch that is fast and reliable and preserves the blood supply to the umbilicus.

  6. Factors Associated With Long-term Outcomes of Umbilical Hernia Repair.

    PubMed

    Shankar, Divya A; Itani, Kamal M F; O'Brien, William J; Sanchez, Vivian M

    2017-05-01

    Umbilical hernia repair is one of the most commonly performed general surgical procedures. However, there is little consensus about the factors that lead to umbilical hernia recurrence. To better understand the factors associated with long-term umbilical hernia recurrence. A retrospective cohort of 332 military veteran patients who underwent umbilical hernia repair was studied between January 1, 1998, and December 31, 2008, at the VA Boston Healthcare System. Recurrence and mortality outcomes were tracked from that period until June 1, 2014. Data were collected on patient characteristics, operative, and postoperative factors and univariate and multivariable analyses were used to assess which factors were significantly associated with umbilical hernia recurrence and mortality. All patients with primary umbilical hernia repair, with or without a concurrent unrelated procedure, were included in the study. Patients excluded were those who underwent umbilical hernia repair as a part of another major planned procedure with abdominal incisions. Data were collected from June 1, 2014, to November 1, 2015. Statistical analysis was performed from November 2, 2015, to April 1, 2016. The primary study outcomes were umbilical hernia recurrence and death. Of the 332 patients in this study, 321 (96.7%) were male, mean age was 58.4 years, and mean (SD) time of follow-up was 8.5 (4.1) years. The hernia recurrence rate was 6.0% (n = 20) at a mean 3.1 years after index repair (median, 1.0-year; range, 0.33-13 years). The primary suture repair recurrence rate was 9.8% (16 of 163 patients), and the mesh repair recurrence rate was 2.4% (4 of 169 patients). On univariate analysis, ascites (P = .02), liver disease (P = .02), diabetes (P = .04), and primary suture (nonmesh) repairs (P = .04) were significantly associated with increased recurrence rates. Patients who had a history of hernias (125 [39%]) were less likely to have umbilical hernia recurrences (χ21 = 4

  7. Factors Associated With Long-term Outcomes of Umbilical Hernia Repair

    PubMed Central

    Shankar, Divya A.; Itani, Kamal M. F.; O’Brien, William J.

    2017-01-01

    Importance Umbilical hernia repair is one of the most commonly performed general surgical procedures. However, there is little consensus about the factors that lead to umbilical hernia recurrence. Objective To better understand the factors associated with long-term umbilical hernia recurrence. Design, Setting, and Participants A retrospective cohort of 332 military veteran patients who underwent umbilical hernia repair was studied between January 1, 1998, and December 31, 2008, at the VA Boston Healthcare System. Recurrence and mortality outcomes were tracked from that period until June 1, 2014. Data were collected on patient characteristics, operative, and postoperative factors and univariate and multivariable analyses were used to assess which factors were significantly associated with umbilical hernia recurrence and mortality. All patients with primary umbilical hernia repair, with or without a concurrent unrelated procedure, were included in the study. Patients excluded were those who underwent umbilical hernia repair as a part of another major planned procedure with abdominal incisions. Data were collected from June 1, 2014, to November 1, 2015. Statistical analysis was performed from November 2, 2015, to April 1, 2016. Main Outcomes and Measures The primary study outcomes were umbilical hernia recurrence and death. Results Of the 332 patients in this study, 321 (96.7%) were male, mean age was 58.4 years, and mean (SD) time of follow-up was 8.5 (4.1) years. The hernia recurrence rate was 6.0% (n = 20) at a mean 3.1 years after index repair (median, 1.0-year; range, 0.33-13 years). The primary suture repair recurrence rate was 9.8% (16 of 163 patients), and the mesh repair recurrence rate was 2.4% (4 of 169 patients). On univariate analysis, ascites (P = .02), liver disease (P = .02), diabetes (P = .04), and primary suture (nonmesh) repairs (P = .04) were significantly associated with increased recurrence rates. Patients who had a history of

  8. Umbilical Negative Pressure Dressing for Transumbilical Appendectomy in Childern.

    PubMed

    Seifarth, Federico G; Kundu, Neilendu; Guerron, Alfredo D; Garland, Mary M; Gaffley, Michaela W G; Worley, Sarah; Knight, Colin G

    2016-01-01

    Transumbilical laparoscopic-assisted appendectomy (TULAA) carries a high risk for surgical site infection. We investigated the effect of a bio-occlusive umbilical vacuum dressing on wound infection rates after TULAA for patients with acute appendicitis and compared to it with a conventional 3-port appendectomy with a nonvacuum dressing. This study was a retrospective chart review of 1377 patients (2-20 years) undergoing laparoscopic appendectomy for acute appendicitis in 2 tertiary care referral centers from January 2007 through December 2012. Twenty-two different operative technique/dressing variations were documented. The 6 technique/dressing groups with >50 patients were assessed, including a total of 1283 patients. The surgical site infection rate of the 220 patients treated with TULAA and application of an umbilical vacuum dressing with dry gauze is 1.8% (95% CI, 0.0-10.3%). This compares to an infection rate of 4.1% (95% CI, 1.3-10.5%) in 97 patients with dry dressing without vacuum. In the 395 patients who received an umbilical vacuum dressing with gauze and bacitracin, the surgical site infection rate was found to be 4.3% (95% CI, 2.7-6.8%). Application of an umbilical negative-pressure dressing with dry gauze lowers the rate of umbilical site infections in patients undergoing transumbilical laparoscopic-assisted appendectomy for acute appendicitis.

  9. 56. DETAIL OF PAYLOAD ELECTRICAL AND AIRCONDITIONING UMBILICAL CONNECTIONS ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    56. DETAIL OF PAYLOAD ELECTRICAL AND AIR-CONDITIONING UMBILICAL CONNECTIONS ON NORTH FACE OF SLC-3W UMBILICAL MAST - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  10. Coronary artery dilatation in toxic shock-like syndrome: the Kawasaki disease shock syndrome.

    PubMed

    Yim, Deane; Ramsay, James; Kothari, Darshan; Burgner, David

    2010-11-01

    Kawasaki disease is a common systemic vasculitis of childhood that may result in life-threatening coronary artery abnormalities. Despite an overlap of clinical features with toxic shock syndrome, children with Kawasaki disease generally do not develop shock. We report two cases of older children who presented with a toxic shock-like illness, and were diagnosed with Kawasaki disease when coronary artery abnormalities were found on echocardiography, in keeping with the recently described 'Kawasaki disease shock syndrome'. Clinicians should consider Kawasaki disease in all children presenting with toxic shock and assess for coronary artery damage.

  11. Androgen Concentrations in Umbilical Cord Blood and Their Association with Maternal, Fetal and Obstetric Factors

    PubMed Central

    Keelan, Jeffrey A.; Mattes, Eugen; Tan, HaiWei; Dinan, Andrew; Newnham, John P.; Whitehouse, Andrew J. O.; Jacoby, Peter; Hickey, Martha

    2012-01-01

    The aim of this study was to measure umbilical blood androgen concentrations in a birth cohort using a highly specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay and assesses the effects of sex, labor, and gestational age on fetal androgen levels at birth. We performed a prospective cohort study of androgen concentrations in mixed arterial and venous umbilical cord serum from 803 unselected singleton pregnancies from a general obstetric population in Western Australia. Total testosterone (TT), Δ4-androstenedione, and dehydroepiandrosterone were extracted from archived cord serum samples and measured using LC-MS/MS. SHBG was measured by ELISA; free testosterone (FT) and bioavailable testosterone (BioT) values were also calculated. Median values for all three androgens were generally lower than previously published values. Levels of TT, FT, BioT, and SHBG were significantly higher in male verses female neonates (P<0.0001), while dehydroepiandrosterone levels were higher in females (P<0.0001). Labor was associated with a significant (∼15–26%) decrease in median cord blood TT and FT levels (both sexes combined), but a modest (∼16–31%) increase in SHBG, Δ4-androstenedione, and dehydroepiandrosterone concentrations. TT and FT were significantly negatively correlated with gestational age at delivery, while SHBG, Δ4-androstenedione, and dehydroepiandrosterone were positively correlated. Antenatal glucocorticoid administration also had a significant effect in the multiple regression models. This is the first study to report umbilical cord androgen levels in a large unselected population of neonates using LC-MS/MS. Our findings suggest that previous studies have over-estimated cord androgen levels, and that fetal, maternal, and obstetric factors influence cord androgen levels differentially. Caution should be exercised when interpreting previously-published data that have not taken all of these factors into account. PMID:22916165

  12. Maximal blood flow acceleration analysis in the early diastolic phase for aortocoronary artery bypass grafts: a new transit-time flow measurement predictor of graft failure following coronary artery bypass grafting.

    PubMed

    Handa, Takemi; Orihashi, Kazumasa; Nishimori, Hideaki; Yamamoto, Masaki

    2016-11-01

    Maximal graft flow acceleration (max df/dt) determined using transit-time flowmetry (TTFM) in the diastolic phase was assessed as a potential predictor of graft failure for aortocoronary artery (AC) bypass grafts in coronary artery bypass patients. Max df/dt was retrospectively measured in 114 aortocoronary artery bypass grafts. TTFM data were fitted to a 9-polynomial curve, which was derived from the first-derivative curve, to measure max df/dt (9-polynomial max df/dt). Abnormal TTFM was defined as a mean flow of <15 ml/min, a pulsatility index of >5 or a diastolic filling ratio of <50 %. Postoperative assessments were routinely performed by coronary artery angiography (CAG) at 1 year after surgery. Using TTFM, 68 grafts were normal, 4 of which were failing on CAG, and 46 grafts were abnormal, 21 of which were failing on CAG. 9-polynomial max df/dt was significantly lower in abnormal TTFM/failing by the CAG group compared with abnormal TTFM/patent by the CAG group (1.08 ± 0.89 vs. 2.05 ± 1.51 ml/s(2), respectively; P < 0.01, Mann-Whitney U test, Holm adjustment). TTFM 9-polynomial max df/dt in the early diastolic phase may be a promising predictor of future graft failure for AC bypass grafts, particularly in abnormal TTFM grafts.

  13. Optimization of informed consent for umbilical cord blood banking.

    PubMed

    Sugarman, Jeremy; Kurtzberg, Joanne; Box, Tamara L; Horner, Ronnie D

    2002-12-01

    The purpose of this project was to evaluate the informed consent process for donation to a public umbilical cord blood bank. Telephone interviews were conducted with 170 women who had given consent to donate their newborn infants' umbilical cord blood. Of the 170 women who were contacted, 96.8% of the women reported that all their questions had been answered. Nevertheless, approximately one third of the respondents did not consider themselves to be in research, and almost one quarter of the respondents did not know how to contact the umbilical cord blood bank if they or their infant became seriously ill. Further, a substantial proportion of the respondents did not understand the full range of alternatives to donation and incorrectly endorsed potential benefits. Informed consent could be optimized by (1) having those personnel who obtain consent emphasize that banking involves research and to explain the true benefits of donation, (2) ensuring that parents know how and when to contact the umbilical cord blood bank after donation, and (3) using phone surveys to continue assessments and to monitor changes in the process.

  14. Adverse Pregnancy Outcomes after Abnormal First Trimester Screening for Aneuploidy

    PubMed Central

    Goetzl, Laura

    2010-01-01

    Women with abnormal first trimester screening but with a normal karyotype are at risk for adverse pregnancy outcomes. A nuchal translucency >3.5mm is associated with an increased risk of subsequent pregnancy loss, fetal infection, fetal heart abnormalities and other structural abnormalities. Abnormal first trimester analytes are also associated with adverse pregnancy outcomes but the predictive value is less impressive. As a single marker, PAPP-A <1st%ile has a good predictive value for subsequent fetal growth restriction. Women with PAPP-A<5th%ile should undergo subsequent risk assessment with routine MSAFP screening with the possible addition of uterine artery PI assessment in the midtrimester. PMID:20638576

  15. Simultaneous Umbilical Hernia Repair with Transumbilical Ventriculoperitoneal Shunt Placement.

    PubMed

    Montalbano, Michael J; Loukas, Marios; Oakes, W Jerry; Tubbs, R Shane

    2017-01-01

    Recently, placement of a ventriculoperitoneal shunt via a transumbilical approach has been reported. Herein, we report the repair of an umbilical hernia via the same incision and introduction of the distal end of a ventricultoperitoneal shunt into the peritoneal cavity in 3 patients. A case illustration is included. Both hernia repair and placement of the distal end of the ventriculoperitoneal shunt were uncomplicated in our small case series. To our knowledge, simultaneous repair of an umbilical hernia followed by transumbilical shunt placement has not been reported. As umbilical hernias are so common in infants, this finding, based on our experience, should not exclude placement of peritoneal tubing in the same setting. © 2017 S. Karger AG, Basel.

  16. Abnormal vessel of the ear associated with congenital arteriovenous malformation in the postauricular region.

    PubMed

    Dixit, Shilpi Gupta; Dixit, Rakesh

    2013-08-01

    Variations in the branching pattern of the common, external, and internal carotid arteries can present as arteriovenous malformations, and their basis can be explained embryologically. Our case was a rare variation presenting as a congenital, very gradually increasing bluish painless swelling at the region of the left lobule of the ear arising from an abnormal vessel (from the postauricular artery) which was explored under general anesthesia through a postauricular curved incision. The abnormal vessel and other feeding vessels were ligated and a sclerosing agent injected. Anomalies of pharyngeal arch arteries like our case can be found resulting from the persistence of channels that normally disappear, and prior knowledge of these anomalies is essential before surgeries like mastoidectomy to prevent alarming hemorrhage.

  17. Newborn umbilical cord and skin care in Sylhet District, Bangladesh: Implications for promotion of umbilical cord cleansing with topical chlorhexidine

    PubMed Central

    Alam, Ashraful; Ali, Nabeel Ashraf; Sultana, Nighat; Mullany, Luke C.; Teela, Katherine C.; Khan, Nazib Uz Zaman; Baqui, Abdullah H.; Arifeen, Shams El; Mannan, Ishtiaq; Darmstadt, Gary L.; Winch, Peter J.

    2010-01-01

    Background Newborn cord care practices may directly contribute to infections, which account for a large proportion of the 4 million annual global neonatal deaths. This formative research study assessed current umbilical and skin care knowledge and practices for neonates in Sylhet, Bangladesh in preparation for a cluster-randomised trial of the impact of topical chlorhexidine cord cleansing on neonatal mortality and omphalitis. Methodology Unstructured interviews (n=60), structured observations (n=20), rating and ranking exercises (n=40), and household surveys (n=400) were conducted to elicit specific behaviours regarding newborn cord and skin care practices. These included hand-washing, skin and cord care at the time of birth, persons engaged in cord care, cord cutting practices, topical applications to the cord at the time of birth, wrapping/dressing of the cord stump, and use of skin-to-skin care. Results Ninety percent of deliveries occurred at home. The umbilical cord was almost always (98%) cut after delivery of the placenta, and cut by mothers in more than half the cases (57%). Substances were commonly (52%) applied to the stump after cord cutting; turmeric was the most common application (83%). Umbilical stump care revolved around bathing, skin massage with mustard oil, and heat massage on the umbilical stump. Forty-two percent of newborns were bathed on the day of birth. Mothers were the principal provider for skin and cord care during the neonatal period and 9% reported umbilical infections in their infants. Discussion Unhygienic cord care practices are prevalent in the study area. Efforts to promote hand washing, cord cutting with clean instruments, and avoiding unclean home applications to the cord may reduce exposure and improve neonatal outcomes. Such efforts should broadly target a range of caregivers, including mothers and other female household members. PMID:19057570

  18. Retinal vessel diameter and estimated cerebrospinal fluid pressure in arterial hypertension: the Beijing Eye Study.

    PubMed

    Jonas, Jost B; Wang, Ningli; Wang, Shuang; Wang, Ya Xing; You, Qi Sheng; Yang, Diya; Wei, Wen Bin; Xu, Liang

    2014-09-01

    Hypertensive retinal microvascular abnormalities include an increased retinal vein-to-artery diameter ratio. Because central retinal vein pressure depends on cerebrospinal fluid pressure (CSFP), we examined whether the retinal vein-to-artery diameter ratio and other retinal hypertensive signs are associated with CSFP. Participants of the population-based Beijing Eye Study (n = 1,574 subjects) underwent measurement of the temporal inferior and superior retinal artery and vein diameter. CSFP was calculated as 0.44 × body mass index (kg/m(2)) + 0.16 × diastolic blood pressure (mm Hg) - 0.18 × age (years) - 1.91. Larger retinal vein diameters and higher vein-to-artery diameter ratios were significantly associated with higher estimated CSFP (P = 0.001) in multivariable analysis. In contrast, temporal inferior retinal arterial diameter was marginally associated (P = 0.03) with estimated CSFP, and temporal superior artery diameter was not significantly associated (P = 0.10) with estimated CSFP; other microvascular abnormalities, such as arteriovenous crossing signs, were also not significantly associated with estimated CSFP. In a reverse manner, higher estimated CSFP as a dependent variable in the multivariable analysis was associated with wider retinal veins and higher vein-to-artery diameter ratio. In the same model, estimated CSFP was not significantly correlated with retinal artery diameters or other retinal microvascular abnormalities. Correspondingly, arterial hypertension was associated with retinal microvascular abnormalities such as arteriovenous crossing signs (P = 0.003), thinner temporal retinal arteries (P < 0.001), higher CSFP (P < 0.001), and wider retinal veins (P = 0.001) or, as a corollary, with a higher vein-to-artery diameter ratio in multivariable analysis. Wider retinal vein diameters are associated with higher estimated CSFP and vice versa. In arterial hypertension, an increased retinal vein-to-artery diameter ratio depends on elevated CSFP

  19. Umbilical hernias and anterior fontanelle size in Jamaican children.

    PubMed

    Cohen, I P

    1989-06-01

    This cross-sectional study documents the frequent occurrence of umbilical hernias among Jamaican children and suggests, for the first time, that the presence of an umbilical hernia may be associated with larger anterior fontanelle dimensions. It also demonstrates that data about the people a community health officer serves can be recorded during a busy clinic schedule.

  20. The umbilical and paraumbilical veins of man.

    PubMed Central

    Martin, B F; Tudor, R G

    1980-01-01

    During its transit through the umbilicus structural changes occur in the thick wall of the extra-abdominal segment of the umbilical vein whereby the components of the intra-abdominal segment acquire an essentially longitudinal direction and become arranged in fibro-elastic and fibro-muscular zones. The vein lumen becomes largely obliterated by asymmetrical proliferation of loose subendothelial conective tissue. The latter forms a new inner zone within which a small segment of the lumen persists in an eccentric position. This residual lumen transmits blood to the portal system from paraumbilical and systemic sources, and is retained in the upper part of the vein, even in old age. A similar process of lumen closure is observed in the ductus venosus. In early childhood the lower third of the vein undergoes breakdown, with fatty infiltration, resulting in its complete division into vascular fibro-elastic strands, and in old age some breakdown occurs in the outermost part of the wall of the upper two thirds. The paraumbilical veins are thick-walled and of similar structure to the umbilical vein. Together they constitute an accessory portal system which is confined between the layers of the falciform ligament and is in communication with the veins of the ventral abdominal wall. The constituents form an ascending series, namely, Burow's veins, the umbilical vein, and Sappey's inferior and superior veins. The main channel of Sappey's inferior veins may be the remnant of the right umbilical vein since it communicates with the right rectus sheath and often communicates directly with the portal system within the right lobe of the liver. The results are of significance in relation to clinical usage of the umbilical vein. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 11 Fig. 12 Fig. 13 Fig. 14 Fig. 15 Fig. 16 Fig. 17 Fig. 18 Fig. 19 Fig. 20 Fig. 21 Fig. 22 Fig. 23 Fig. 24 Fig. 25 Fig. 26 Fig. 27 Fig. 28 Fig. 29 PMID:7400038

  1. Umbilical Hernia in Peritoneal Dialysis Patients: Surgical Treatment and Risk Factors.

    PubMed

    Banshodani, Masataka; Kawanishi, Hideki; Moriishi, Misaki; Shintaku, Sadanori; Ago, Rika; Hashimoto, Shinji; Nishihara, Masahiro; Tsuchiya, Shinichiro

    2015-12-01

    No previous reports have focused on surgical treatments and risk factors of umbilical hernia alone in peritoneal dialysis (PD) patients. Herein, we evaluated the treatments and risk factors. A total of 411 PD patients were enrolled. Of the 15 patients with umbilical hernia (3.6%), six underwent hernioplasty. There was no recurrence in five patients treated with tension-free hernioplasty. The mean PD vintage after onset of hernia in the hernioplasty group tended to be longer than that in the non-hernioplasty group. An incarcerated hernia occurred in one non-hernioplasty patient. Although the incidence was significantly higher among women (P = 0.02), female sex was not a risk factor for umbilical hernia (P = 0.08). Our findings suggest that umbilical hernias should be repaired for continuing PD. Furthermore, there were no significant risk factors for umbilical hernia in PD patients. Future studies with larger sample groups are required to elucidate these risk factors. © 2015 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.

  2. Association of umbilical hernia with volume of ascites in liver cirrhosis: a retrospective observational study.

    PubMed

    Wang, Ran; Qi, Xingshun; Peng, Ying; Deng, Han; Li, Jing; Ning, Zheng; Dai, Junna; Hou, Feifei; Zhao, Jiancheng; Guo, Xiaozhong

    2016-11-01

    Umbilical hernia is a common abdominal complication in cirrhotic patients with ascites. Our study aimed to evaluate the correlation of umbilical hernia with the volume of ascites. Cirrhotic patients that underwent axial abdominopelvic computed tomography (CT) scans at our hospital between June 2012 and June 2014 were eligible. All CT images were reviewed to confirm the presence of umbilical hernia. The volume of ascites was estimated by five-point method. One hundred and fifty-seven patients were enrolled into this study. Among them, 101 patients had ascites and 6 patients had umbilical hernia. Alkaline phosphatase (AKP) and serum sodium were significantly lower in patients with umbilical hernia (P = 0.008, P = 0.011, respectively). Child-Pugh scores and the volume of ascites were significantly higher in patients with umbilical hernia (P = 0.03, P < 0.0001, respectively). Correlation analysis demonstrated that the volume of ascites, Child-Pugh scores, and blood ammonia had positive correlations with umbilical hernia (r = 0.4579, P < 0.0001; r = 0.175, P = 0.03; r = 0.342, P = 0.001, respectively) and that serum sodium had a negative correlation with umbilical hernia (r = -0.203, P = 0.011). In patients with ascites ≥2000 mL, only AKP was significantly associated with umbilical hernia (P = 0.0497). No variables were significantly associated with umbilical hernia in a subgroup analysis of patients matched according to the volume of ascites. The volume of ascites has a positive correlation with umbilical hernia. However, the factors associated with umbilical hernia in patients with severe ascites remain unclear. © 2016 Chinese Cochrane Center, West China Hospital of Sichuan University and John Wiley & Sons Australia, Ltd.

  3. 126. REDUNDANCY SYSTEM CONTROLS FOR UMBILICAL MAST RETRACTION AT LOWER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    126. REDUNDANCY SYSTEM CONTROLS FOR UMBILICAL MAST RETRACTION AT LOWER LEFT SIDE OF HYDRAULIC CONTROL PANEL IN UMBILICAL MAST PUMP ROOM (209), LSB (BLDG. 751) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  4. 109. REDUNDANCY SYSTEM CONTROLS FOR UMBILICAL MAST RETRACTION AT LOWER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    109. REDUNDANCY SYSTEM CONTROLS FOR UMBILICAL MAST RETRACTION AT LOWER LEFT SIDE OF HYDRAULIC CONTROL PANEL IN UMBILICAL MAST PUMP ROOM (109), LSB (BLDG. 770) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  5. Umbilical cord rupture: a case report and review of literature.

    PubMed

    Naidu, Madhusudhan; Nama, Vivek; Karoshi, Mahantesh; Kakumani, Vijayasri; Worth, Richard

    2007-01-01

    The umbilical cord acts as a mechanical conduit between the fetus and placenta, allowing movement of water and nutrient substances between the fetal circulation and the amniotic fluid. Complications can occur antenatally or intranatally and are usually acute events that require immediate delivery to prevent intrauterine death. Even though the majority of the cord complications are unpreventable, significant improvement in perinatal mortality and morbidity can be achieved if such an event can be predicted. Umbilical cord rupture is not uncommon, but significantly underreported. We present an unusual cause of umbilical cord rupture and a review of literature.

  6. Umbilical Hernia Repair: Overview of Approaches and Review of Literature.

    PubMed

    Appleby, Paul W; Martin, Tasha A; Hope, William W

    2018-06-01

    Umbilical hernias are ubiquitous, and surgery is indicated in symptomatic patients. Umbilical hernia defects can range from small (<1 cm) to very large/complex hernias, and treatment options should be tailored to the clinical situation. Open, laparoscopic, and robotic options exist for repair, with each having its advantages and disadvantages. In general, mesh should be used for repair, because it has been shown to decrease recurrence rates, even in small hernias. Although outcomes are generally favorable after umbilical hernia repairs, some patients have chronic complaints that are mostly related to recurrences. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Mini-extracorporeal circulation minimizes coagulation abnormalities and ameliorates pulmonary outcome in coronary artery bypass grafting surgery.

    PubMed

    Zeitani, J; Buccisano, F; Nardella, S; Flaminio, M; Prati, P; Chiariello, G; Venditti, A; Chiariello, L

    2013-07-01

    Hemostasis is impaired during CABG and coagulation abnormalities often result in clinically relevant organ dysfunctions, eventually increasing morbidity and mortality rates. Fifteen consecutive patients with coronary artery disease submitted to conventional extracorporeal circulation (cECC) have been compared with 15 matched patients, using mini-ECC (MECC). Postoperative lung function was evaluated according to gas exchange, intubation time and lung injury score. In the MECC group, thrombin-antithrombin complex levels (TaTc), prothrombin fragments (PF1+2) formation and thromboelastography (TEG) clotting times were lower compared to the cECC group (p=0.002 and p<0.001, respectively) whereas postoperative blood loss was higher in the cECC group (p=0.030) and more patients required blood transfusion (p=0.020). In the MECC group, postoperative gas exchange values were better, intubation time shorter and lung injury score lower (p<0.001 for all comparisons). Our study suggests that MECC induces less coagulation disorders, leading to lower postoperative blood loss and better postoperative lung function. This approach may be advantageous in high-risk patients.

  8. Giant Ovarian Tumor Presenting as an Incarcerated Umbilical Hernia: A Case Report

    PubMed Central

    Aydın, Özgür; Onur, Erdal; Çelik, Nilufer Yiğit; Moray, Gökhan

    2009-01-01

    We report a rare case of a giant ovarian tumor presenting as an incarcerated umbilical hernia. A 61-yr-old woman was admitted to the hospital with severe abdominal pain, an umbilical mass, nausea and vomiting. On examination, a large, irreducible umbilical hernia was found. The woman underwent an urgent operation for a possible strangulated hernia. A large, multilocular tumor was found. The tumor was excised, and a total abdominal hysterectomy and bilateral salphingo-oophorectomy were performed. The woman was discharged 6 days after her admission. This is the first report of incarcerated umbilical hernia containing a giant ovarian tumor within the sac. PMID:19543424

  9. Perfusion deficits detected by arterial spin-labeling in patients with TIA with negative diffusion and vascular imaging.

    PubMed

    Qiao, X J; Salamon, N; Wang, D J J; He, R; Linetsky, M; Ellingson, B M; Pope, W B

    2013-01-01

    A substantial portion of clinically diagnosed TIA cases is imaging-negative. The purpose of the current study is to determine if arterial spin-labeling is helpful in detecting perfusion abnormalities in patients presenting clinically with TIA. Pseudocontinuous arterial spin-labeling with 3D background-suppressed gradient and spin-echo was acquired on 49 patients suspected of TIA within 24 hours of symptom onset. All patients were free of stroke history and had no lesion-specific findings on general MR, DWI, and MRA sequences. The calculated arterial spin-labeling CBF maps were scored from 1-3 on the basis of presence and severity of perfusion disturbance by 3 independent observers blinded to patient history. An age-matched cohort of 36 patients diagnosed with no cerebrovascular events was evaluated as a control. Interobserver agreement was assessed by use of the Kendall concordance test. Scoring of perfusion abnormalities on arterial spin-labeling scans of the TIA cohort was highly concordant among the 3 observers (W = 0.812). The sensitivity and specificity of arterial spin-labeling in the diagnosis of perfusion abnormalities in TIA was 55.8% and 90.7%, respectively. In 93.3% (70/75) of the arterial spin-labeling CBF map readings with positive scores (≥2), the brain regions where perfusion abnormalities were identified by 3 observers matched with the neurologic deficits at TIA onset. In this preliminary study, arterial spin-labeling showed promise in the detection of perfusion abnormalities that correlated with clinically diagnosed TIA in patients with otherwise normal neuroimaging results.

  10. Hepatic laceration as a life-threatening complication of umbilical venous catheterization.

    PubMed

    Gülcan, Hande; Hanta, Deniz; Törer, Birgin; Temiz, Adbülkerim; Demir, Senay

    2011-01-01

    Umbilical venous catheterization is an intravenous infusion route for maintenance fluids, medications, blood products, and parenteral nutrition in preterm neonates. However, this procedure may be associated with several complications, such as infection, thrombosis, vessel perforation, and cardiac and hepatic injuries. Hepatic laceration is a rare but life-threatening complication of umbilical venous catheterization that is a result of direct injury through the liver parenchyma. Here, we present a preterm newborn with hepatic laceration as a rare and serious complication of umbilical venous catheterization.

  11. Profile of paediatric umbilical hernias managed at Federal Medical Centre Umuahia.

    PubMed

    Ezomike, U O; Ituen, M A; Ekpemo, S C; Eke, C B; Eke, B C

    2012-01-01

    Umbilical hernias are common in children but many resolve spontaneously within the first five years of life. Most umbilical herniorrhaphies in our environment are due to symptomatic hernias which constitute a small percentage of all umbilical hernias. A retrospective review of all pediatric patients with UH treated at Federal Medical Centre Umuahia, Abia State from February 2001 to February 2011. There were 22 patients but only 20 of the folders were found and analyzed. They were made up of 11 males and 9 females with a mean age of 6.19 +/- 0.83 years and median age of 6 years. Nine(7 males and 2 females) had acute incarcerations, nine (3 males and 6 females) had recurrent umbilical pains without incarceration and two (1 male and 1 female) had recurrent incarcerations. Age range for acute incarceration was 2-8 years (mean: 4.69 years, median: 4 years); recurrent umbilical pains was 4 months -15 years (mean: 7.7 years, median: 8 years) and for recurrent incarceration 2-10 years (mean: 6 years). All had standard umbilical hernia repairs except one whose parents declined surgery after reduction of acute incarceration. One patient with acute incarceration had gangrenous bowel with hernia sac abscess and was offered bowel resection with end-to-end anastomosis. On short-term follow-up, the symptoms resolved in all the patients following surgery. Five patients had six complications: 1 exuberant granulation tissue, 2 stitch reactions, 2 superficial wound dehiscence and one superficial wound infection. There were no mortalities and no recurrence on short-term follow-up. Only one patient (5%) registered under the National Health Insurance Scheme (NHIS). Active observation of all umbilical hernias at all ages will ensure early detection of complications and prompt treatment. Elective repair of umbilical hernias in patientsabove five years with fascia defect greater than 1.5cm is encouraged. Comprehensive NHIS will ensure early presentation and reduced complications.

  12. 127. HYDRAULIC CONTROLS AND GAUGES FOR THE UMBILICAL MAST ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    127. HYDRAULIC CONTROLS AND GAUGES FOR THE UMBILICAL MAST ON UPPER RIGHT SIDE OF HYDRAULIC CONTROL PANEL IN UMBILICAL MAST PUMP ROOM (209), LSB (BLDG. 751) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  13. 123. UMBILICAL MAST PUMP ROOM (209), LSB (BLDG. 751). PUMP ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    123. UMBILICAL MAST PUMP ROOM (209), LSB (BLDG. 751). PUMP ON LEFT; HYDRAULIC CONTROL PANEL FOR UMBILICAL MAST AND TRENCH DOORS IN CENTER OF ROOM, FACING WEST. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  14. The conception, birth, and growth of a missile umbilical system

    NASA Technical Reports Server (NTRS)

    Nordman, G. W.

    1977-01-01

    The design development of the Sprint 2 and the Improved Sprint 2 Missile System umbilical system is reviewed. Unique system requirements, umbilical designs considered to meet the requirements, and the problems encountered and solutions derived during the design and development testing of the selected systems are described.

  15. 42. VIEW OF UMBILICAL MAST AND LAUNCH PAD FROM MST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    42. VIEW OF UMBILICAL MAST AND LAUNCH PAD FROM MST BASE. LAUNCHER IS BEHIND UMBILICAL MAST AND RAIL SYSTEM IS PARALLEL TO MAST ON RIGHT AND LEFT. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  16. Ethical issues relating the the banking of umbilical cord blood in Mexico.

    PubMed

    Serrano-Delgado, V Moises; Novello-Garza, Barbara; Valdez-Martinez, Edith

    2009-08-14

    Umbilical cord banks are a central component, as umbilical cord tissue providers, in both medical treatment and scientific research with stem cells. But, whereas the creation of umbilical cord banks is seen as successful practice, it is perceived as a risky style of play by others. This article examines and discusses the ethical, medical and legal considerations that arise from the operation of umbilical cord banks in Mexico. A number of experts have stated that the use of umbilical cord goes beyond the mere utilization of human tissues for the purpose of treatment. This tissue is also used in research studies: genetic studies, studies to evaluate the effectiveness of new antibiotics, studies to identify new proteins, etc. Meanwhile, others claim that the law and other norms for the functioning of cord banks are not consistent and are poorly defined. Some of these critics point out that the confidentiality of donor information is handled differently in different places. The fact that private cord banks offer their services as "biological insurance" in order to obtain informed consent by promising the parents that the tissue that will be stored insures the health of their child in the future raises the issue of whether the consent is freely given or given under coercion. Another consideration that must be made in relation to privately owned cord banks has to do with the ownership of the stored umbilical cord. Conflicts between moral principles and economic interests (non-moral principles) cause dilemmas in the clinical practice of umbilical cord blood storage and use especially in privately owned banks. This article presents a reflection and some of the guidelines that must be followed by umbilical cord banks in order to deal with these conflicts. This reflection is based on the fundamental notions of ethics and public health and seeks to be a contribution towards the improvement of umbilical cord banks' performance.

  17. Ethical issues relating to the banking of umbilical cord blood in Mexico

    PubMed Central

    2009-01-01

    Background Umbilical cord banks are a central component, as umbilical cord tissue providers, in both medical treatment and scientific research with stem cells. But, whereas the creation of umbilical cord banks is seen as successful practice, it is perceived as a risky style of play by others. This article examines and discusses the ethical, medical and legal considerations that arise from the operation of umbilical cord banks in Mexico. Discussion A number of experts have stated that the use of umbilical cord goes beyond the mere utilization of human tissues for the purpose of treatment. This tissue is also used in research studies: genetic studies, studies to evaluate the effectiveness of new antibiotics, studies to identify new proteins, etc. Meanwhile, others claim that the law and other norms for the functioning of cord banks are not consistent and are poorly defined. Some of these critics point out that the confidentiality of donor information is handled differently in different places. The fact that private cord banks offer their services as "biological insurance" in order to obtain informed consent by promising the parents that the tissue that will be stored insures the health of their child in the future raises the issue of whether the consent is freely given or given under coercion. Another consideration that must be made in relation to privately owned cord banks has to do with the ownership of the stored umbilical cord. Summary Conflicts between moral principles and economic interests (non-moral principles) cause dilemmas in the clinical practice of umbilical cord blood storage and use especially in privately owned banks. This article presents a reflection and some of the guidelines that must be followed by umbilical cord banks in order to deal with these conflicts. This reflection is based on the fundamental notions of ethics and public health and seeks to be a contribution towards the improvement of umbilical cord banks' performance. PMID:19678958

  18. Umbilical Stiffness Matrix Characterization and Testing for Microgravity Science Payloads

    NASA Technical Reports Server (NTRS)

    Engberg, Robert C.

    2003-01-01

    This paper describes efforts of testing and analysis of various candidate cables and umbilicals for International Space Station microgravity science payloads. The effects of looping, large vs. small displacements, and umbilical mounting configurations were assessed. A 3-DOF stepper motor driven fixture was used to excite the umbilicals. Forces and moments were directly measured in all three axes with a 6-DOF load cell in order to derive suitable stiffness matrices for design and analysis of vibration isolation controllers. Data obtained from these tests were used to help determine the optimum type and configuration of umbilical cables for the International Space Station microgravity science glovebox (MSG) vibration isolation platform. The data and procedures can also be implemented into control algorithm simulations to assist in validation of actively controlled vibration isolation systems. The experimental results of this work are specific in support of the Glovebox Integrated Microgravity Isolation Technology (g-LIMIT) isolation platform, to be located in the microgravity science glovebox aboard the U.S. Destiny Laboratory Module.

  19. Orion Service Module Umbilical (OSMU) Lift & Preparation for Ins

    NASA Image and Video Library

    2017-03-13

    Preparations are underway to lift the bracket for the Orion Service Module Umbilical (OSMU) up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  20. Orion Service Module Umbilical (OSMU) Lift & Preparation for Ins

    NASA Image and Video Library

    2017-03-13

    A crane positions the bracket for the Orion Service Module Umbilical (OSMU) for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  1. Orion Service Module Umbilical (OSMU) Lift & Preparation for Ins

    NASA Image and Video Library

    2017-03-13

    A crane lifts the bracket for the Orion Service Module Umbilical (OSMU) high up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  2. Treatment of umbilical hernia and recti muscles diastasis without a periumbilical incision.

    PubMed

    Kulhanek, J; Mestak, O

    2013-08-01

    Postpartum rectus diastasis eventually combined with umbilical hernia is a condition that is frequently treated by plastic surgeons and general surgeons. Standard treatment of this condition is abdominoplasty with a periumbilical incision, which often results in an umbilical incision or an inverted-T scar. Limited incision abdominoplasty differs from traditional abdominoplasty by disconnecting the umbilical stalk from the abdominal wall during flap dissection, thus allowing the resection of excess skin above and under the umbilicus without causing periumbilical scarring. We conducted a retrospective cohort study of women undergoing a limited scar abdominoplasty without a periumbilical incision for the treatment of a separation of the recti muscles and/or an umbilical hernia. We recorded the postoperative complications and patient satisfaction with the results of the treatment. We operated on 50 patients from 2002 to 2010. We followed the patients for 2-8 years. The most common complication, as with other abdominoplasty procedures, was minor dehiscention in the middle part of the wound, which occurred in 16 % (n = 8) of the patients. All of these complications were treated conservatively. No recurrence of diastasis or umbilical hernia was observed. Extended miniabdominoplasty with a low suprapubic incision and umbilical caudalization for treating the diastasis of the abdominal rectus muscles and/or an umbilical hernia is an excellent method that results in a small, hidden scar. This method is especially beneficial for young, slim women with an abdominal wall deformity after pregnancy.

  3. Umbilical hernia following gastroschisis closure: a common event?

    PubMed

    Tullie, L G C; Bough, G M; Shalaby, A; Kiely, E M; Curry, J I; Pierro, A; De Coppi, P; Cross, K M K

    2016-08-01

    To assess incidence and natural history of umbilical hernia following sutured and sutureless gastroschisis closure. With audit approval, we undertook a retrospective clinical record review of all gastroschisis closures in our institution (2007-2013). Patient demographics, gastroschisis closure method and umbilical hernia occurrence were recorded. Data, presented as median (range), underwent appropriate statistical analysis. Fifty-three patients were identified, gestation 36 weeks (31-38), birth weight 2.39 kg (1-3.52) and 23 (43 %) were male. Fourteen patients (26 %) underwent sutureless closure: 12 primary, 2 staged; and 39 (74 %) sutured closure: 19 primary, 20 staged. Sutured closure was interrupted sutures in 24 patients, 11 pursestring and 4 not specified. Fifty patients were followed-up over 53 months (10-101) and 22 (44 %) developed umbilical hernias. There was a significantly greater hernia incidence following sutureless closure (p = 0.0002). In sutured closure, pursestring technique had the highest hernia rate (64 %). Seven patients underwent operative hernia closure; three secondary to another procedure. Seven patients had their hernias resolve. One patient was lost to follow-up and seven remain under observation with no reported complications. There is a significant umbilical hernia incidence following sutureless and pursestring sutured gastroschisis closure. This has not led to complications and the majority have not undergone repair.

  4. Cryopreservation of human vascular umbilical cord cells under good manufacturing practice conditions for future cell banks

    PubMed Central

    2012-01-01

    Background In vitro fabricated tissue engineered vascular constructs could provide an alternative to conventional substitutes. A crucial factor for tissue engineering of vascular constructs is an appropriate cell source. Vascular cells from the human umbilical cord can be directly isolated and cryopreserved until needed. Currently no cell bank for human vascular cells is available. Therefore, the establishment of a future human vascular cell bank conforming to good manufacturing practice (GMP) conditions is desirable for therapeutic applications such as tissue engineered cardiovascular constructs. Materials and methods A fundamental step was the adaption of conventional research and development starting materials to GMP compliant starting materials. Human umbilical cord artery derived cells (HUCAC) and human umbilical vein endothelial cells (HUVEC) were isolated, cultivated, cryopreserved (short- and long-term) directly after primary culture and recultivated subsequently. Cell viability, expression of cellular markers and proliferation potential of fresh and cryopreserved cells were studied using trypan blue staining, flow cytometry analysis, immunofluorescence staining and proliferation assays. Statistical analyses were performed using Student’s t-test. Results Sufficient numbers of isolated cells with acceptable viabilities and homogenous expression of cellular markers confirmed that the isolation procedure was successful using GMP compliant starting materials. The influence of cryopreservation was marginal, because cryopreserved cells mostly maintain phenotypic and functional characteristics similar to those of fresh cells. Phenotypic studies revealed that fresh cultivated and cryopreserved HUCAC were positive for alpha smooth muscle actin, CD90, CD105, CD73, CD29, CD44, CD166 and negative for smoothelin. HUVEC expressed CD31, CD146, CD105 and CD144 but not alpha smooth muscle actin. Functional analysis demonstrated acceptable viability and sufficient

  5. Cryopreservation of human vascular umbilical cord cells under good manufacturing practice conditions for future cell banks.

    PubMed

    Polchow, Bianca; Kebbel, Kati; Schmiedeknecht, Gerno; Reichardt, Anne; Henrich, Wolfgang; Hetzer, Roland; Lueders, Cora

    2012-05-16

    In vitro fabricated tissue engineered vascular constructs could provide an alternative to conventional substitutes. A crucial factor for tissue engineering of vascular constructs is an appropriate cell source. Vascular cells from the human umbilical cord can be directly isolated and cryopreserved until needed. Currently no cell bank for human vascular cells is available. Therefore, the establishment of a future human vascular cell bank conforming to good manufacturing practice (GMP) conditions is desirable for therapeutic applications such as tissue engineered cardiovascular constructs. A fundamental step was the adaption of conventional research and development starting materials to GMP compliant starting materials. Human umbilical cord artery derived cells (HUCAC) and human umbilical vein endothelial cells (HUVEC) were isolated, cultivated, cryopreserved (short- and long-term) directly after primary culture and recultivated subsequently. Cell viability, expression of cellular markers and proliferation potential of fresh and cryopreserved cells were studied using trypan blue staining, flow cytometry analysis, immunofluorescence staining and proliferation assays. Statistical analyses were performed using Student's t-test. Sufficient numbers of isolated cells with acceptable viabilities and homogenous expression of cellular markers confirmed that the isolation procedure was successful using GMP compliant starting materials. The influence of cryopreservation was marginal, because cryopreserved cells mostly maintain phenotypic and functional characteristics similar to those of fresh cells. Phenotypic studies revealed that fresh cultivated and cryopreserved HUCAC were positive for alpha smooth muscle actin, CD90, CD105, CD73, CD29, CD44, CD166 and negative for smoothelin. HUVEC expressed CD31, CD146, CD105 and CD144 but not alpha smooth muscle actin. Functional analysis demonstrated acceptable viability and sufficient proliferation properties of cryopreserved HUCAC

  6. Design of the Core Stage Inter-Tank Umbilical {CSITU) Compliance Mechanism

    NASA Technical Reports Server (NTRS)

    Smith, Kurt R.

    2013-01-01

    Project Goals: a) Design the compliance mechanism for the CSITU system to a 30% level -3D models completed in Pro/Engineer -Relevant design analysis b) Must meet all system requirements and establish basis for proceeding with detailed design. Tasks to be completed: A design that meets requirements for the 30% design review, 01/16/2013. Umbilical arms provide commodities to the launch vehicle prior to T-0. Commodities can range anywhere from hydraulics, pneumatics, cryogenic, electrical, ECS, etc ... Umbilicals commonly employ truss structures to deliver commodities to vehicle. Common configurations include: -Tilt-up -Swing Arm -Hose Drape -Drop Arm Umbilical arms will be mounted to Mobile Launch Platform. SLS currently has 9 T-0 umbilical arms. The compliance refers to the ability of the umbilical to adjust to minor changes in vehicle location. The compliance mechanism refers to the mechanism on the ground support equipment {GSE) that compensates for these changes. For the CSITU, these minor changes, or vehicle excursions, can be up to +4 in. Excursions refer to movements of the vehicle caused by wind loads and thermal expansion. It is ideal to have significant vertical compliance so a passive secondary release mechanism may be implemented.

  7. Usefulness of an abnormal ankle-brachial index for detecting multivessel coronary disease in patients with acute coronary syndrome.

    PubMed

    Núñez, Daniel; Morillas, Pedro; Quiles, Juan; Cordero, Alberto; Guindo, Josep; Soria, Federico; Mazón, Pilar; Lekuona, Iñaki; Rodríguez-Padial, Luis; Llácer, Angel; González-Juanatey, José Ramón; Bertomeu, Vicente

    2010-01-01

    The presence of peripheral arterial disease in patients with coronary artery disease is associated with a poor cardiovascular outcome. However, the majority of affected patients are asymptomatic and the condition is underdiagnosed. The ankle-brachial index (ABI) provides a simple method of diagnosis. The aim of this study was to assess the usefulness of an abnormal ABI for identifying multivessel coronary artery disease in patients with acute coronary syndrome (ACS). We analyzed data on all ACS patients included in the PAMISCA multicenter study (with 94 participating hospitals) who underwent catheterization during admission. Patients were diagnosed with multivessel coronary disease if two or more major epicardial vessels or the left main coronary artery, or both, were affected. An ABI 1.4 was considered abnormal. The study included 1031 patients with a mean age of 67.7 years. Of these, 542 had multivessel disease (52.6%). Compare with those without multivessel disease, these patients were older (66.6 years vs. 62.6 years; P< .001), had higher prevalences of hypertension (65.9% vs. 56.2%; P< .005), diabetes mellitus (40.6% vs. 26.0%; P< .001) and hypercholesterolemia (89.1% vs. 80.4%; P< .001), and were more likely to have a history of cardiovascular disease (30.1% vs. 13.9%; P< .001) or an abnormal ABI (45.4% vs. 30.3%; P< .001). Multivariate analysis showed that the presence of an abnormal ABI was associated with an increased risk of multivessel disease (odds ratio=1.58; 95% confidence interval, 1.16-2.15; P< .05). In patients with ACS, an abnormal ABI was independently associated with the risk of multivessel coronary artery disease.

  8. Orion Service Module Umbilical (OSMU) Lift & Preparation for Ins

    NASA Image and Video Library

    2017-03-13

    Crane specialists monitor the progress as the bracket for the Orion Service Module Umbilical (OSMU) is lifted up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  9. Orion Service Module Umbilical (OSMU) Lift & Preparation for Ins

    NASA Image and Video Library

    2017-03-13

    A view from below the mobile launcher shows a crane positioning the bracket for the Orion Service Module Umbilical (OSMU) high up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  10. Orion Service Module Umbilical (OSMU) Lift & Preparation for Ins

    NASA Image and Video Library

    2017-03-13

    Crane specialists monitor the progress as the bracket for the Orion Service Module Umbilical (OSMU) is lifted high up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  11. Orion Service Module Umbilical (OSMU) Lift & Preparation for Ins

    NASA Image and Video Library

    2017-03-13

    In this view looking down from high up on the mobile launcher, a crane positions the bracket for the Orion Service Module Umbilical (OSMU) for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  12. Platelet abnormalities in adults with severe pulmonary arterial hypertension related to congenital heart defects (Eisenmenger syndrome).

    PubMed

    Remková, Anna; Šimková, Iveta; Valkovičová, Tatiana; Kaldarárová, Monika

    2016-12-01

    Patients with severe pulmonary arterial hypertension suffer from life-threatening thrombotic and bleeding complications. The aim of this study was to compare selected platelet, endothelial, and coagulation parameters in healthy volunteers and patients with severe pulmonary arterial hypertension because of congenital heart defects. The study included healthy volunteers (n = 50) and patients with cyanotic congenital heart defects classified as Eisenmenger syndrome (n = 41). We investigated platelet count, mean platelet volume, and platelet aggregation - spontaneous and induced by various concentrations of five agonists. Von Willebrand factor (vWF), fibrinogen, factor VIII and XII, plasminogen activator inhibitor, antithrombin, D-dimer, and antiphospholipid antibodies were also investigated. We found a decreased platelet count [190 (147-225) vs. 248 (205-295) 10 l, P < 0.0001], higher mean platelet volume [10.9 (10.1-12.0) vs. 10.2 (9.4-10.4) fl, P < 0.0001], and significantly decreased platelet aggregation (induced by five agonists, in various concentrations) in patients with Eisenmenger syndrome compared with controls. These changes were accompanied by an increase of plasma vWF antigen [141.6 (108.9-179.1) vs. 117.4 (9.2-140.7) IU/dl, P = 0.022] and serum anti-β2-glycoprotein [2.07 (0.71-3.41) vs. 0.47 (0.18-0.99) U/ml, P < 0.0001]. Eisenmenger syndrome is accompanied by platelet abnormalities. Thrombocytopenia with increased platelet size is probably due to a higher platelet turnover associated with platelet activation. Impaired platelet aggregation can reflect specific platelet behaviour in patients with Eisenmenger syndrome. These changes can be related both to bleeding and to thrombotic events. A higher vWF antigen may be a consequence of endothelial damage in Eisenmenger syndrome, but the cause for an increase of anti-β2-glycoprotein is unknown.

  13. Acute Abdomen Secondary to Incarcerated Umbilical Hernia after Treatment of Massive Cirrhotic Ascites

    PubMed Central

    Tan, Hiang Keat; Chang, Pik Eu

    2013-01-01

    Umbilical herniation is common in patients with liver cirrhosis and ascites. Rarely, they suffer from incarceration and strangulation of the umbilical hernia after treatment of ascites. We report 3 cases of umbilical hernia incarceration following removal of massive ascites with different treatment modalities. Physicians managing this group of patients should be aware of this rare and potentially fatal complication. PMID:25374722

  14. Umbilical hernia with cholelithiasis and hiatal hernia: a clinical entity similar to Saint's triad.

    PubMed

    Yamanaka, Takahiro; Miyazaki, Tatsuya; Kumakura, Yuji; Honjo, Hiroaki; Hara, Keigo; Yokobori, Takehiko; Sakai, Makoto; Sohda, Makoto; Kuwano, Hiroyuki

    2015-01-01

    We experienced two cases involving the simultaneous presence of cholelithiasis, hiatal hernia, and umbilical hernia. Both patients were female and overweight (body mass index of 25.0-29.9 kg/m(2)) and had a history of pregnancy and surgical treatment of cholelithiasis. Additionally, both patients had two of the three conditions of Saint's triad. Based on analysis of the pathogenesis of these two cases, we consider that these four diseases (Saint's triad and umbilical hernia) are associated with one another. Obesity is a common risk factor for both umbilical hernia and Saint's triad. Female sex, older age, and a history of pregnancy are common risk factors for umbilical hernia and two of the three conditions of Saint's triad. Thus, umbilical hernia may readily develop with Saint's triad. Knowledge of this coincidence is important in the clinical setting. The concomitant occurrence of Saint's triad and umbilical hernia may be another clinical "tetralogy."

  15. Arterial Wall Imaging in Pediatric Stroke.

    PubMed

    Dlamini, Nomazulu; Yau, Ivanna; Muthusami, Prakash; Mikulis, David J; Elbers, Jorina; Slim, Mahmoud; Askalan, Rand; MacGregor, Daune; deVeber, Gabrielle; Shroff, Manohar; Moharir, Mahendranath

    2018-04-01

    Arteriopathy is common in childhood arterial ischemic stroke (AIS) and predicts stroke recurrence. Currently available vascular imaging techniques mainly image the arterial lumen rather than the vessel wall and have a limited ability to differentiate among common arteriopathies. We aimed to investigate the value of a magnetic resonance imaging-based technique, namely noninvasive arterial wall imaging (AWI), for distinguishing among arteriopathy subtypes in a consecutive cohort of children presenting with AIS. Children with confirmed AIS and magnetic resonance angiography underwent 3-Tesla AWI including T1-weighted 2-dimensional fluid-attenuated inversion recovery fast spin echo sequences pre- and post-gadolinium contrast. AWI characteristics, including wall enhancement, wall thickening, and luminal stenosis, were documented for all. Twenty-six children with AIS had AWI. Of these, 9 (35%) had AWI enhancement. AWI enhancement was associated with anterior circulation magnetic resonance angiography abnormality and cortical infarction in 8 of 9 (89%) children and normal magnetic resonance angiography with posterior circulation subcortical infarction in 1 (1 of 9; 11%) child. AWI enhancement was not seen in 17 (65%), 10 (59%) of whom had an abnormal magnetic resonance angiography. Distinct patterns of pre- and postcontrast signal abnormality were demonstrated in the vessel wall in the region of interest in children with transient cerebral arteriopathy, arterial dissection, primary central nervous system angiitis, dissecting aneurysm, and cardioembolic stroke. AWI is a noninvasive, high-resolution magnetic resonance AWI technique, which can be successfully used in children presenting with AIS. Patterns of AWI enhancement are recognizable and associated with specific AIS pathogeneses. Further studies are required to assess the additional diagnostic utility of AWI over routine vascular imaging techniques, in childhood AIS. © 2018 American Heart Association, Inc.

  16. Laparoscopic transabdominal preperitoneal approach for umbilical hernia with rectus diastasis.

    PubMed

    Capitano, Sante

    2017-08-01

    Rectus diastasis, when coexistent with umbilical hernia, can benefit from mesh-based repair of the midline. Laparoscopic correction of an umbilical hernia involves the placement of a mesh in the peritoneal cavity, but this comes with the risk of bowel complications. However, newly developed dual-sided composite meshes have helped to reduce this risk. Four men and three women with umbilical hernia and rectus diastasis were treated with laparoscopic transabdominal preperitoneal repair. Composite mesh with a hydrophilic 3-D polyester textile on the parietal side and an absorbable collagen barrier on the peritoneal side were placed in the preperitoneal pocket after hernial sac reduction. Mean hernia size was 2.5 cm, and no recurrences were observed during the mean follow-up period of 9.2 months. The laparoscopic transabdominal preperitoneal approach for umbilical hernia and rectus diastasis may be a safe surgical option when trying to avoid potential complications related to intra-abdominal mesh positioning. © 2017 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  17. Orion Service Module Umbilical (OSMU) Installation on Mobile Launcher (ML)

    NASA Image and Video Library

    2017-03-13

    Cranes and rigging are being used to lift the bracket for the Orion Service Module Umbilical (OSMU) up for installation on the mobile launcher tower. The tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  18. Abnormal placentation.

    PubMed

    Bauer, Samuel T; Bonanno, Clarissa

    2009-04-01

    Abnormal placentation poses a diagnostic and treatment challenge for all providers caring for pregnant women. As one of the leading causes of postpartum hemorrhage, abnormal placentation involves the attachment of placental villi directly to the myometrium with potentially deeper invasion into the uterine wall or surrounding organs. Surgical procedures that disrupt the integrity of uterus, including cesarean section, dilatation and curettage, and myomectomy, have been implicated as key risk factors for placenta accreta. The diagnosis is typically made by gray-scale ultrasound and confirmed with magnetic resonance imaging, which may better delineate the extent of placental invasion. It is critical to make the diagnosis before delivery because preoperative planning can significantly decrease blood loss and avoid substantial morbidity associated with placenta accreta. Aggressive management of hemorrhage through the use of uterotonics, fluid resuscitation, blood products, planned hysterectomy, and surgical hemostatic agents can be life-saving for these patients. Conservative management, including the use of uterine and placental preservation and subsequent methotrexate therapy or pelvic artery embolization, may be considered when a focal accreta is suspected; however, surgical management remains the current standard of care.

  19. Orion Service Module Umbilical (OSMU) Lift & Preparation for Ins

    NASA Image and Video Library

    2017-03-13

    Construction workers and crane specialists high up on the mobile launcher tower monitor the progress as a crane positions the bracket for the Orion Service Module Umbilical (OSMU) for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  20. Clinical usefulness of temporal artery biopsy.

    PubMed Central

    Vilaseca, J; González, A; Cid, M C; Lopez-Vivancos, J; Ortega, A

    1987-01-01

    To assess the diagnostic usefulness of temporal artery biopsy in temporal arteritis (TA) and establish clinical features capable of predicting its positivity we have retrospectively studied the biopsy specimens and the clinical features of 103 patients who had undergone temporal artery biopsy. Temporal artery biopsy reached a positive predictive value of 90.2% with respect to the final diagnosis based on the criteria proposed by Ellis and Ralston and the clinical course. The simultaneous presence of recent onset headache, jaw claudication, and abnormalities of the temporal arteries on physical examination had a specificity of 94.8% with respect to the histological diagnosis and of 100% with respect to final diagnosis. The presence of any of these clinical features, though of little specificity (34.4%), had a sensitivity of 100% with respect to histological diagnosis, selecting a group of patients in whom temporal artery biopsy has more discriminative value. PMID:3592783

  1. Rupture of Umbilical Hernia with Evisceration in a Newborn - A Case Report.

    PubMed

    Kittur, Dinesh H; Bhandarkar, Kailas P; Patil, Santosh V; Jadhav, Sudhakar S

    2017-01-01

    Most umbilical hernias in infants do not need surgery and the ring will eventually close. Occasionally few complications can arise and incarceration is most common. Spontaneous rupture of the hernia and eventual evisceration is a rarely seen complication. A 3-week-old neonate having umbilical hernia presented with rupture of the sac with evisceration of bowel within a few days of first visit. No underlying cause like umbilical sepsis was found. The baby had emergency repair of the hernia with an uneventful recovery.

  2. Incarceration of umbilical hernia after radiological insertion of a Denver peritoneovenous shunt.

    PubMed

    Ohta, Kengo; Shimohira, Masashi; Hashizume, Takuya; Kawai, Tatsuya; Kurosaka, Kenichiro; Suzuki, Kazushi; Watanabe, Kenichi; Shibamoto, Yuta

    2013-03-01

    We report a rare complication of incarceration of an umbilical hernia after Denver peritoneovenous shunt placement. A 50-year-old man presented with refractory ascites from liver cirrhosis. He also had an umbilical hernia. Because the ascites became uncontrollable, Denver peritoneovenous shunting was performed. The operation was successful and the ascites decreased. Ten days later, however, incarceration of the umbilical hernia occurred. A surgical repair was performed, but he died 2 days later. The cause of death was considered to be sepsis.

  3. The relation between umbilical cord characteristics and the outcome of external cephalic version.

    PubMed

    Kuppens, Simone M I; Waerenburgh, Evelyne R; Kooistra, Libbe; van der Donk, Riet W P; Hasaart, Tom H M; Pop, Victor J M

    2011-05-01

    Umbilical cords of fetuses in breech presentation differ in length and coiling from their cephalic counterparts and it might be hypothesised that these cord characteristics may in turn affect ECV outcome. To investigate the relation between umbilical cord characteristics and the outcome of external cephalic version (ECV). Prospective cohort study. Women (>35 weeks gestation) with a singleton fetus in breech presentation, suitable for external cephalic version. Demographic, lifestyle and obstetrical parameters were assessed at intake. ECV success was based on cephalic presentation on ultrasound post-ECV. Umbilical cord length (UCL) and umbilical coiling index (UCI) were measured after birth. The relation between umbilical cord characteristics (cord length and coiling) and the success of external cephalic version. ECV success rate was overall 79/146 (54%), for multiparas 37/46(80%) and for nulliparas 42/100 (42%). Multiple logistic regression showed that UCL (OR: 1.04, CI: 1.01-1.07), nulliparity (OR: 0.20, CI: 0.08-0.51), frank breech (OR: 0.37, 95% CI: 0.15-0.90), body mass index (OR: 0.85, CI: 0.76-0.95), placenta anterior (OR: 0.27, CI: 0.12-0.63) and birth weight (OR: 1.002, CI: 1.001-1.003) were all independently related to ECV success. Umbilical cord length is independently related to the outcome of ECV, whereas umbilical coiling index is not. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. PP043. Oxidative stress in the maternal body also affects the fetus in preeclamptic women with fetal growth restriction.

    PubMed

    Watanabe, Kazushi; Iwasaki, Ai; Mori, Toshitaka; Kimura, Chiharu; Matsushita, Hiroshi; Shinohara, Koichi; Wakatsuki, Akihiko

    2013-04-01

    The purpose of the present study was to determine whether oxidative stress occurring in the maternal body also affects the fetus in preeclamptic women with FGR. We ∥@consecutively recruited 17 preeclamptic women with FGR, 16 preeclamptic women without FGR, and 16 healthy pregnant women with uncomplicated pregnancy. We measured concentrations of derivatives of reactive oxygen metabolites (d-ROMs) as a marker of oxygen free radicals in a maternal vein, umbilical artery, and umbilical vein. ∥@Maternal d-ROM levels were higher in preeclamptic groups compared to the control group. Umbilical artery and vein d-ROM levels were elevated in preeclamptic women with FGR compared to the control group. Umbilical artery d-ROM levels were significantly higher than in the vein in preeclamptic women with FGR, but not in those without FGR. Umbilical arterial blood pH was significantly lower in preeclamptic women with FGR. The partial pressure of oxygen (PaO2) in umbilical arterial blood tended to be lower in preeclamptic women with FGR (p=0.08). The partial pressure of carbon dioxide (PaCO2) in umbilical arterial blood was significantly higher in preeclamptic women with FGR. These results indicate that oxidative stress occurring in the maternal body also affects the fetus in preeclamptic women with FGR. Copyright © 2013. Published by Elsevier B.V.

  5. Eviscerated urinary bladder via ruptured umbilical hernia: a rare occurrence.

    PubMed

    Pandey, A; Kumar, V; Gangopadhyay, A N; Upadhyaya, V D

    2008-06-01

    Umbilical hernia is a common problem encountered in children. Rupture and evisceration are very rare phenomena, and the usual content that is eviscerated is the bowel. We present an infant who had a ruptured umbilical hernia with eviscerated urinary bladder dome. As this is the first case of its kind, it is being reported with a brief review of literature.

  6. The Umbilical Benz Incision for Reduced Port Surgery in Pediatric Patients

    PubMed Central

    Amano, Hizuru; Kawashima, Hiroshi; Deie, Kyoichi; Murase, Naruhiko; Makita, Satoshi; Yokota, Kazuki; Tanaka, Yujiro

    2015-01-01

    Background and Objectives: For reduced port surgery in pediatric patients, the initial umbilical incision plays an important role in both functional ability and cosmetic impact. Larger umbilical incisions enable better manipulation of forceps, extraction of larger surgical specimens, and easier exteriorization of the intestine for anastomosis. We have pursued an incision of the small pediatric umbilicus that allows for enlargement of the orifice of the abdominal opening with preservation of the natural umbilical profile. This article aims to present a new umbilical incision technique and describe the outcomes. Methods: We devised a new umbilical incision technique for reduced port surgery in pediatric patients. Our incision is made in an inverted Y shape (Benz incision), allowing for access port device insertion. The Benz incision technique was applied between November 2010 and May 2014 and was retrospectively studied. Results: Seventy-five patients underwent Benz incisions. The median age of all patients was 6 years 6 months (range, 26 days to 18 years), and the median body weight was 21.7 kg (range, 3.1–54.3 kg). Benz incisions were applied for various procedures, including reduced port surgery with hepaticojejunostomy for congenital biliary dilatation, portojejunostomy for biliary atresia, Meckel diverticulectomy, tumor resection, varicocelectomy, cholecystectomy, splenectomy, ileus surgery, ileocecal resection, and total colectomy. All patients were successfully treated, without a significant increase in operating time or severe complications. The cosmetic profile of the umbilicus was maintained after surgery. Conclusion: The Benz incision is a feasible, effective, and scarless approach for reduced port surgery in pediatric patients whose umbilical rings are too small for the conventional approach. PMID:25848185

  7. Temporary prophylactic intravascular balloon occlusion of the common iliac arteries before cesarean hysterectomy for controlling operative blood loss in abnormal placentation.

    PubMed

    Chou, Min Min; Kung, Hsiao Fan; Hwang, Jen I; Chen, Wei Chi; Tseng, Jenn Jhy

    2015-10-01

    The purpose of this study was to investigate the efficacy and safety of temporary prophylactic intravascular balloon occlusion of the common iliac arteries (CIA) before planned cesarean hysterectomy for controlling operative blood loss in abnormal placentation. A retrospective study of 13 pregnant women at risk for placenta accreta identified using sequential obstetric ultrasonography and magnetic resonance imaging from January 2007 to December 2009 was performed. Temporary prophylactic intravascular balloon catheterization of the bilateral CIA before cesarean hysterectomy was performed by interventional radiologists. The maximum duration of occlusion time of CIA must not exceed 60 minutes. The primary outcome for this study included estimated blood loss and secondary outcomes included the development of thromboembolism, disseminated intravascular coagulation and surgical complications. Among these 13 patients, the mean age of the patients was 32.8 ± 0.7 years (range 29-37 years). The mean gestational age at cesarean hysterectomy was 32.2 ± 0.9 weeks (range 28-36 weeks), and the mean intraoperative blood loss was 1902.3 ± 578.8 mL (range 500-8000 mL). Operative bleeding was controlled by conservative treatment without additional surgery in two cases. Importantly, two patients (15.8%) had severe complications possibly related to the interventional procedure. One patient was noted to have a popliteal artery thrombosis. A second patient had an external iliac artery thrombosis with 80-90% occlusion. Both patients required antithrombotic treatment without sequelae. With limited experience in this small series, we observed a statistically significant reduction in operative blood loss after the use of temporary prophylactic balloon occlusion of the CIA technique compared with historical controls of similar demographic characteristics previously published (1902.3 ± 578.8 mL, range 500-8000 mL vs. 4445.7 ± 996.48 mL, range 1040-15,000 mL, p = 0.0402). Additionally, two

  8. Transcatheter Arterial Embolization for Upper Gastrointestinal Nonvariceal Hemorrhage: Is Empiric Embolization Warranted?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arrayeh, Elnasif; Fidelman, Nicholas, E-mail: nicholas.fidelman@ucsf.edu; Gordon, Roy L.

    Purpose: To determine whether transcatheter arterial embolization performed in the setting of active gastric or duodenal nonvariceal hemorrhage is efficacious when the bleeding source cannot be identified angiographically. Methods: Records of 115 adult patients who underwent visceral angiography for endoscopically documented gastric (50 patients) or duodenal (65 patients) nonvariceal hemorrhage were retrospectively reviewed. Patients were subdivided into three groups according to whether angiographic evidence of arterial hemorrhage was present and whether embolization was performed (group 1 = no abnormality, no embolization; group 2 = no abnormality, embolization performed [empiric embolization]; and group 3 = abnormality present, embolization performed). Thirty-day ratesmore » and duration of primary hemostasis and survival were compared.ResultsFor patients with gastric sources of hemorrhage, the rate of primary hemostasis at 30 days after embolization was greater when embolization was performed in the setting of a documented angiographic abnormality than when empiric embolization was performed (67% vs. 42%). The rate of primary hemostasis at 30 days after angiography was greater for patients with duodenal bleeding who either underwent empiric embolization (60%) or embolization in the setting of angiographically documented arterial hemorrhage (58%) compared with patients who only underwent diagnostic angiogram (33%). Patients with duodenal hemorrhage who underwent embolization were less likely to require additional invasive procedures to control rebleeding (p = 0.006). Conclusion: Empiric arterial embolization may be advantageous in patients with a duodenal source of hemorrhage but not in patients with gastric hemorrhage.« less

  9. Temporal and quantitative associations of electronic fetal heart rate monitoring patterns and neonatal outcomes†.

    PubMed

    Ogunyemi, Dotun; Jovanovski, Andrew; Friedman, Perry; Sweatman, Brittany; Madan, Ichchha

    2018-04-06

    The objective of this study is to evaluate the associations of electronic fetal heart rate monitoring (EFM) patterns and adverse neonatal outcomes Study design: From 2013 to 2016; 12,067 term, singleton deliveries in labor ≥2 h with abnormal EFM defined as absent accelerations, variable, late or prolonged decelerations, tachycardia, bradycardia, or minimal variability were analyzed as any documentation during labor, in first hour and last hour of labor. Outcomes were composite neonatal adverse outcomes, neonatal intensive care unit (NICU) admission, neonatal hypoxia, neonatal hypoglycemia, umbilical artery pH, and base excess. Independent associations were ascertained using regression analysis. Significant independent associations occurred between any abnormal EFM during the last hour and five adverse neonatal outcomes; between abnormal EFM at any time and one adverse neonatal outcome while there was none with the first hour of labor. In the last hour, accelerations had significant negative associations with three adverse neonatal outcomes, while prolonged decelerations, late decelerations, tachycardia, and bradycardia had significant positive associations with three adverse neonatal outcomes. Throughout labor, increasing accelerations events were significantly negatively correlated with all adverse neonatal outcomes, while increasing frequency of late, variable, and prolonged decelerations were positively associated with five adverse neonatal outcomes. Hierarchical analysis showed that bradycardia/tachycardia contributed only 0.8%, while all EFM periodic changes contributed 1%; the addition of the frequencies of abnormal EFM events contributed 0.6% to the variance in umbilical artery pH and base excess. Terminal EFM patterns are independently associated with neonatal outcomes. Accelerations are protective of adverse neonatal outcomes. Increasing frequency of EFM patterns overtime contributes to neonatal outcome.

  10. Ultrasound-guided rectus sheath block in children with umbilical hernia: Case series.

    PubMed

    Alsaeed, Abdul Hamid; Thallaj, Ahmed; Khalil, Nancy; Almutaq, Nada; Aljazaeri, Ayman

    2013-10-01

    Umbilical hernia repair, a common day-case surgery procedure in children, is associated with a significant postoperative pain. The most popular peripheral nerve blocks used in umbilical hernia repair are rectus sheath infiltration and caudal block. The rectus sheath block may offer improved pain relief following umbilical hernia repair with no undesired effects such as lower limb motor weakness or urinary retention seen with caudal block which might delay discharge from the hospital. Ultrasound guidance of peripheral nerve blocks has reduced the number of complications and improved the quality of blocks. The aim of this case series is to assess the post rectus sheath block pain relief in pediatric patients coming for umbilical surgery. Twenty two (22) children (age range: 1.5-8 years) scheduled for umbilical hernia repair were included in the study. Following the induction of general anesthesia, the ultrasonographic anatomy of the umbilical region was studied with a 5-16 MHz 50 mm linear probe. An ultrasound-guided posterior rectus sheath block of both rectus abdominis muscles (RMs) was performed (total of 44 punctures). An in-plain technique using Stimuplex A insulated facet tip needle 22G 50mm. Surgical conditions, intraoperative hemodynamic parameters, and postoperative analgesia by means of the modified CHEOPS scale were evaluated. ultrasonograghic visualization of the posterior sheath was possible in all patients. The ultrasound guided rectus sheath blockade provided sufficient analgesia in all children with no need for additional analgesia except for one patient who postoperatively required morphine 0.1 mg/kg intravenously. There were no complications. Ultrasound guidance enables performances of an effective rectus sheath block for umbilical hernia. Use of the Stimuplex A insulated facet tip needle 22G 50mm provides easy, less traumatic skin and rectus muscle penetration and satisfactory needle visualiza.

  11. Umbilical hernia in patients with liver cirrhosis: A surgical challenge

    PubMed Central

    Coelho, Julio C U; Claus, Christiano M P; Campos, Antonio C L; Costa, Marco A R; Blum, Caroline

    2016-01-01

    Umbilical hernia occurs in 20% of the patients with liver cirrhosis complicated with ascites. Due to the enormous intraabdominal pressure secondary to the ascites, umbilical hernia in these patients has a tendency to enlarge rapidly and to complicate. The treatment of umbilical hernia in these patients is a surgical challenge. Ascites control is the mainstay to reduce hernia recurrence and postoperative complications, such as wound infection, evisceration, ascites drainage, and peritonitis. Intermittent paracentesis, temporary peritoneal dialysis catheter or transjugular intrahepatic portosystemic shunt may be necessary to control ascites. Hernia repair is indicated in patients in whom medical treatment is effective in controlling ascites. Patients who have a good perspective to be transplanted within 3-6 mo, herniorrhaphy should be performed during transplantation. Hernia repair with mesh is associated with lower recurrence rate, but with higher surgical site infection when compared to hernia correction with conventional fascial suture. There is no consensus on the best abdominal wall layer in which the mesh should be placed: Onlay, sublay, or underlay. Many studies have demonstrated several advantages of the laparoscopic umbilical herniorrhaphy in cirrhotic patients compared with open surgical treatment. PMID:27462389

  12. Umbilical hernia in patients with liver cirrhosis: A surgical challenge.

    PubMed

    Coelho, Julio C U; Claus, Christiano M P; Campos, Antonio C L; Costa, Marco A R; Blum, Caroline

    2016-07-27

    Umbilical hernia occurs in 20% of the patients with liver cirrhosis complicated with ascites. Due to the enormous intraabdominal pressure secondary to the ascites, umbilical hernia in these patients has a tendency to enlarge rapidly and to complicate. The treatment of umbilical hernia in these patients is a surgical challenge. Ascites control is the mainstay to reduce hernia recurrence and postoperative complications, such as wound infection, evisceration, ascites drainage, and peritonitis. Intermittent paracentesis, temporary peritoneal dialysis catheter or transjugular intrahepatic portosystemic shunt may be necessary to control ascites. Hernia repair is indicated in patients in whom medical treatment is effective in controlling ascites. Patients who have a good perspective to be transplanted within 3-6 mo, herniorrhaphy should be performed during transplantation. Hernia repair with mesh is associated with lower recurrence rate, but with higher surgical site infection when compared to hernia correction with conventional fascial suture. There is no consensus on the best abdominal wall layer in which the mesh should be placed: Onlay, sublay, or underlay. Many studies have demonstrated several advantages of the laparoscopic umbilical herniorrhaphy in cirrhotic patients compared with open surgical treatment.

  13. Mercury in the Umbilical Cord: Implications for Risk Assessment for Minamata Disease.

    PubMed Central

    Dalgard, C; Grandjean, P; Jorgensen, PJ; Weihe, P

    1994-01-01

    Umbilical cord tissue was obtained from 50 births in the Faroe Islands, where high mercury intake is due to ingestion of pilot whale meat. The mercury concentration correlated significantly with the frequency of maternal whale meat dinners during pregnancy and with mercury concentrations in umbilical cord blood and in maternal hair. The results were compared with published values for mercury in umbilical cord tissue from 12 infants diagnosed with congenital methylmercury poisoning in Minamata, Japan. From the regression coefficients obtained in the Faroese samples, the median umbilical cord mercury concentration of 4.95 nmol/g dry weight in Minamata would correspond to 668 nmol/l cord blood and 114 nmol/g maternal hair. These levels agree well with other evidence of susceptibility of the fetus to increased exposure to methylmercury. Images Figure 1. Figure 2. PMID:9679113

  14. A tailored three-dimensionally printable agarose-collagen blend allows encapsulation, spreading, and attachment of human umbilical artery smooth muscle cells.

    PubMed

    Köpf, Marius; Campos, Daniela F Duarte; Blaeser, Andreas; Sen, Kshama S; Fischer, Horst

    2016-05-20

    In recent years, novel biofabrication technologies have enabled the rapid manufacture of hydrogel-cell suspensions into tissue-imitating constructs. The development of novel materials for biofabrication still remains a challenge due to a gap between contradicting requirements such as three-dimensional printability and optimal cytocompatibility. We hypothesise that blending of different hydrogels could lead to a novel material with favourable biological and printing properties. In our work, we combined agarose and type I collagen in order to develop a hydrogel blend capable of long-term cell encapsulation of human umbilical artery smooth muscle cells (HUASMCs) and 3D drop-on-demand printing. Different blends were prepared with 0.25%, 0.5%, 0.75%, and 1.5% agarose and 0.2% type I collagen. The cell morphology of HUASMCs and the printing accuracy were assessed for each agarose-collagen combination, keeping the content of collagen constant. The hydrogel blend which displayed sufficient cell spreading and printing accuracy (0.5% agarose, 0.2% type I collagen, AGR0.5COLL0.2) was then characterised based on swelling and degradation over 21 days and mechanical stiffness. The cellular response regarding cell attachment of HUASMCs embedded in the hydrogel blend was further studied using SEM, TEM, and TPLSM. Printing trials were fabricated in a drop-on-demand printing process. The swelling and degradation evaluation showed an average of 20% mass loss and less than 10% swelling. AGR0.5COLL0.2 exhibited significant increase in stiffness compared to pure agarose and type I collagen. In addition, columns of AGR0.5COLL0.2 three centimeters in height were successfully printed submerged in cooled perfluorocarbon, proving the intrinsic printability of the hydrogel blend. Ultimately, a promising novel hydrogel blend showing cell spreading and attachment as well as suitability for bioprinting was identified and could, for example, serve in the manufacture of in vitro 3D models to

  15. Signs of fetal brain sparing are not related to umbilical cord blood gases at birth.

    PubMed

    Cheema, Riffat; Dubiel, Mariusz; Gudmundsson, Saemundur

    2009-07-01

    Fetal chronic hypoxia leads to centralization of circulation in order to spare the vital organs brain, adrenals and the heart. This can be documented by Doppler ultrasound. Increased blood velocity in the fetal middle cerebral artery (MCA) is an acknowledged sign of centralization of circulation in chronic hypoxia, and is called brain sparing. Our aim was to assess the relationship between signs of brain sparing in the MCA and umbilical cord blood gases at birth. A prospective study. Singleton 57 high-risk pregnancies (outcome was compared with 21 normal pregnancies). MCA Doppler was performed within 24 h of elective caesarean section in high-risk pregnancies. Umbilical cord blood gases were analysed at birth. Cord blood gases were related to signs of centralization of fetal circulation in the MCA. No correlation between signs of brain sparing in the MCA and cord blood gases. Apgar score at 5'<7 was seen in three newborns, but only one of these had antenatal signs of brain sparing. Newborns with antenatal brain sparing were admitted more often (p<0.04) and had a longer duration of stay in NICU (p<0.03) compared to newborns without brain sparing. Decreased pulsatility index in MCA is an acknowledged sign of fetal centralization of circulation during chronic hypoxia. However, signs of brain sparing are not related to cord blood gases at birth, which might suggest that redistribution of fetal circulation can maintain normal blood gases for a long time during chronic hypoxia.

  16. PHACES syndrome: a review of eight previously unreported cases with late arterial occlusions.

    PubMed

    Bhattacharya, J J; Luo, C B; Alvarez, H; Rodesch, G; Pongpech, S; Lasjaunias, P L

    2004-03-01

    PHACE and PHACES are acronyms for a syndrome of variable expression comprising posterior cranial fossa malformations, facial haemangiomas, arterial anomalies, aortic coarctation and other cardiac disorders, ocular abnormalities and stenotic arterial disease. We review five girls and three boys aged 1 month-14 years with disorders from this spectrum. Six had large facial haemangiomas but recent reports suggest that small haemangiomas may occur; hence our inclusion of two possible cases. We also focus on the recently recognised feature of progressive intracranial arterial occlusions, present in four of our patients, later than previously recognised, from 4 to 14 years of age. We suggest that many elements of this disorder could reflect an abnormality of cell proliferation and apoptosis.

  17. Chronic hypoxia alters maternal uterine and fetal hemodynamics in the full-term pregnant guinea pig.

    PubMed

    Turan, Sifa; Aberdeen, Graham W; Thompson, Loren P

    2017-10-01

    Placental hypoxia is associated with maternal hypertension, placental insufficiency, and fetal growth restriction. In the pregnant guinea pig, prenatal hypoxia during early gestation inhibits cytotrophoblast invasion of spiral arteries, increases maternal blood pressure, and induces fetal growth restriction. In this study the impact of chronic maternal hypoxia on fetal heart structure was evaluated using four-dimensional echocardiography with spatiotemporal image correlation and tomographic ultrasound, and uterine and umbilical artery resistance/pulsatility indexes and fetal heart function were evaluated using pulsed-wave Doppler ultrasound. Pregnant guinea pigs were exposed to normoxia ( n = 7) or hypoxia (10.5% O 2 , n = 9) at 28-30 days gestation, which was maintained until full term (65 days). At full term, fetal heart structure and outflow tracts were evaluated in the four-chamber view. Fetal heart diastolic function was assessed by E wave-to-A wave diastolic filling ratios (E/A ratios) of both ventricles and systolic function by the myocardial performance index (or Tie) of left ventricles of normoxic ( n = 21) and hypoxic ( n = 17) fetuses. There were no structural abnormalities in fetal hearts. However, hypoxia induced asymmetric fetal growth restriction and increased the placental/fetal weight compared with normoxic controls. Hypoxia increased Doppler resistance and pulsatility indexes in the uterine, but not umbilical, arteries, had no effect on the Tie index, and increased the E/A ratio in left, but not right, ventricles. Thus, prolonged hypoxia, starting at midgestation, increases uterine artery resistance and generates fetal growth restriction at full term. Furthermore, the enhanced cardiac diastolic filling with no changes in systolic function or umbilical artery resistance suggests that the fetal guinea pig systemic circulation undergoes a compensated, adaptive response to prolonged hypoxia exposure. Copyright © 2017 the American Physiological

  18. 44. VIEW OF UMBILICAL MAST AND LAUNCH PAD FROM SOUTHWEST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    44. VIEW OF UMBILICAL MAST AND LAUNCH PAD FROM SOUTHWEST. DOORS FOR THE UMBILICAL MAST TRENCH RAISED FOR MAINTENANCE POSITION OF 10 DEGREES. LAUNCHER IS RIGHT OF MAST; RAILS PARALLEL TO MAST. CONTROL PANELS LEFT TO RIGHT: ELECTRICAL PANEL, COMMUNICATIONS PANEL, AND MAST CONTROL PANEL. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  19. Topical Nitroglycerine for Neonatal Arterial Associated Peripheral Ischemia following Cannulation: A Case Report and Comprehensive Literature Review

    PubMed Central

    Mosalli, Rafat; Elbaz, Mohamed; Paes, Bosco

    2013-01-01

    Arterial cannulation in neonates is usually performed for frequent blood pressure monitoring and blood sampling. The procedure, while easily executed by skilled neonatal staff, can be associated with serious complications such as vasospasm, thrombosis, embolism, hematoma, infection, peripheral nerve damage, ischemia, and tissue necrosis. Several treatment options are available to reverse vascular induced ischemia and tissue damage. Applied interventions depend on the extent of tissue involvement and whether the condition is progressive and deemed life threatening. Standard, noninvasive measures include immediate catheter removal, limb elevation, and warming the contralateral extremity. Topical vasodilators, anticoagulation, thrombolysis, and surgery are considered secondary therapeutic strategies. A comprehensive literature search indicates that topical nitroglycerin has been utilized for the treatment of tissue ischemia in three preterms with umbilical arterial catheters and four with peripheral arterial lines. We report the first successful use of nitroglycerine ointment in a critically ill preterm infant with ischemic hand changes after brachial artery cannulation. PMID:24251058

  20. Corkscrew basilar artery as an incidental finding on neuroimaging.

    PubMed

    Moser, Franklin G; Sarnat, Harvey B; Maya, Marcel M; Menkes, John H

    2007-11-01

    We report on an incidental finding of a markedly tortuous basilar artery in a 6-year-old child. The child underwent a computed tomography scan for minor head trauma, and a basilar artery abnormality was discovered, i.e., a markedly tortuous basilar artery without any other congenital anomalies or syndromes. After an exhaustive workup including computed tomography, magnetic resonance imaging, magnetic resonance angiography, computed tomographic angiography, and genetic tests for associated genetic syndromes, no intervention was deemed necessary. The embryonic etiology and clinical implications are discussed.

  1. Catamenial Pain in Umbilical Hernia with Spontaneous Reduction: An Unusual Presentation of a Rare Entity.

    PubMed

    Pandey, Divya; Sharma, Ritu; Salhan, Sudha

    2015-08-01

    Spontaneous umbilical endometriosis occurring in absence of any previous abdominal or uterine surgery is extremely atypical. Its association with umbilical hernia is very rare and hernia getting spontaneously resolved has not been reported in literature so far. Here we report a case of a patient with spontaneous umbilical endometriosis associated with umbilical hernia which led to spontaneous hernia reduction. This was also associated with multiple uterine fibromyoma and bilateral ovarian endometrioma which were simultaneously treated by total abdominal hysterectomy with bilateral salpingo-oopherectomy along with surgical excision of the endometriotic tissue and repair of the abdominal wall defect. To the best of our knowledge, this is the first described case of spontaneous umbilical hernia reduction due to development of endometriosis.

  2. Deletion of Rbpj from postnatal endothelium leads to abnormal arteriovenous shunting in mice

    PubMed Central

    Nielsen, Corinne M.; Cuervo, Henar; Ding, Vivianne W.; Kong, Yupeng; Huang, Eric J.; Wang, Rong A.

    2014-01-01

    Arteriovenous malformations (AVMs) are tortuous vessels characterized by arteriovenous (AV) shunts, which displace capillaries and shunt blood directly from artery to vein. Notch signaling regulates embryonic AV specification by promoting arterial, as opposed to venous, endothelial cell (EC) fate. To understand the essential role of endothelial Notch signaling in postnatal AV organization, we used inducible Cre-loxP recombination to delete Rbpj, a mediator of canonical Notch signaling, from postnatal ECs in mice. Deletion of endothelial Rbpj from birth resulted in features of AVMs by P14, including abnormal AV shunting and tortuous vessels in the brain, intestine and heart. We further analyzed brain AVMs, as they pose particular health risks. Consistent with AVM pathology, we found cerebral hemorrhage, hypoxia and necrosis, and neurological deficits. AV shunts originated from capillaries (and possibly venules), with the earliest detectable morphological abnormalities in AV connections by P8. Prior to AV shunt formation, alterations in EC gene expression were detected, including decreased Efnb2 and increased Pai1, which encodes a downstream effector of TGFβ signaling. After AV shunts had formed, whole-mount immunostaining showed decreased Efnb2 and increased Ephb4 expression within AV shunts, suggesting that ECs were reprogrammed from arterial to venous identity. Deletion of Rbpj from adult ECs led to tortuosities in gastrointestinal, uterine and skin vascular beds, but had mild effects in the brain. Our results demonstrate a temporal requirement for Rbpj in postnatal ECs to maintain proper artery, capillary and vein organization and to prevent abnormal AV shunting and AVM pathogenesis. PMID:25209249

  3. Mucinous cystadenoma of the appendix presenting as an umbilical hernia: A case report.

    PubMed

    Ren, Bingbing; Meng, Xiangchao; Cao, Z I; Guo, Chunli; Zhang, Zili

    2016-06-01

    Mucinous cystadenoma of the appendix is a rare condition that develops as a result of proliferation of mucin-secreting cells in an occluded appendix. Mucinous cystadenoma of the appendix presenting as an umbilical hernia is a rare clinical entity. The most common causes of this condition are known to be ascites, hepatitis and cirrhosis; however, the patient in the present study, was diagnosed as hepatitis- and cirrhosis-negative, with no history of chronic coughing or constipation. The aim of the present study was to report a rare case of mucinous cystadenoma of the appendix presenting as an umbilical hernia in a 66-year-old female patient. The patient had a 6-month history of a reducible mass in the umbilical region and was diagnosed with umbilical hernia. Computed tomography and ultrasonography were performed and revealed massive ascites. Ultimately, a laparoscopic appendectomy was performed and borderline mucinous appendiceal cystadenoma of low malignant potential was confirmed. In addition, the present study discussed the association between mucinous cystadenoma of the appendix and umbilical hernia, as well as the diagnostic process and treatment strategies.

  4. Mucinous cystadenoma of the appendix presenting as an umbilical hernia: A case report

    PubMed Central

    REN, BINGBING; MENG, XIANGCHAO; CAO, ZI; GUO, CHUNLI; ZHANG, ZILI

    2016-01-01

    Mucinous cystadenoma of the appendix is a rare condition that develops as a result of proliferation of mucin-secreting cells in an occluded appendix. Mucinous cystadenoma of the appendix presenting as an umbilical hernia is a rare clinical entity. The most common causes of this condition are known to be ascites, hepatitis and cirrhosis; however, the patient in the present study, was diagnosed as hepatitis- and cirrhosis-negative, with no history of chronic coughing or constipation. The aim of the present study was to report a rare case of mucinous cystadenoma of the appendix presenting as an umbilical hernia in a 66-year-old female patient. The patient had a 6-month history of a reducible mass in the umbilical region and was diagnosed with umbilical hernia. Computed tomography and ultrasonography were performed and revealed massive ascites. Ultimately, a laparoscopic appendectomy was performed and borderline mucinous appendiceal cystadenoma of low malignant potential was confirmed. In addition, the present study discussed the association between mucinous cystadenoma of the appendix and umbilical hernia, as well as the diagnostic process and treatment strategies. PMID:27313766

  5. The introduction of umbilical cord lactate measurement and associated neonatal outcomes in a South African tertiary hospital labor ward.

    PubMed

    Allanson, E R; Pattinson, R C; Nathan, E A; Dickinson, J E

    2018-05-01

    To investigate the utility of umbilical artery (UA) lactate measurements in a South African hospital for assessing intrapartum care and predicting neonatal outcomes. From 3 March-12 November 2014, we conducted a prospective cohort study of UA lactate levels at Kalafong Hospital, Pretoria, South Africa. Following birth, a UA blood sample (<0.5uL) was taken from a double-clamped segment of cord and the lactate measured. Maternal and neonatal characteristics and outcomes were recorded. During the study, there were 4668 deliveries; including 1091 emergency cesarean and 154 instrumental deliveries. A lactate was recorded for 946 deliveries (20.3%). 190 babies required neonatal resuscitation, with an optimal cutoff for lactate of 5.45 mmol/L (sensitivity 68%, specificity 72%). 124 babies required nursery admission with the optimal cutoff for lactate 4.95 mmol/L (sensitivity 61%, specificity 59%). 55 babies had an Apgar score <7 at 5 min and the optimal lactate for this outcome was 5.65 mmol/L (sensitivity 64%, specificity of 69%). Umbilical lactate can be used in a middle-low resource setting as a measurement of intrapartum hypoxia, with reasonable sensitivity and specificity for the prediction of, or need for, resuscitation, admission to the nursery, and low Apgar scores.

  6. Prenatal diagnosis of persistent right umbilical vein - Incidence and clinical impact. A prospective study.

    PubMed

    Krzyżanowski, Arkadiusz; Swatowski, Dariusz; Gęca, Tomasz; Kwiatek, Maciej; Stupak, Aleksandra; Woźniak, Sławomir; Kwaśniewska, Anna

    2018-03-02

    Persistent right umbilical vein (PRUV) is usually an isolated finding but it may be accompanied by other fetal malformations. We aimed to determine the incidence of prenatally diagnosed PRUV in a referral population, assess the neonatal outcome and discuss the findings together with those from previous publications. A total of 2360 women with low-risk singleton pregnancies were examined in the second and third trimesters. A transabdominal convex volume transducer was used. B-mode was applied in each patient. Scanning of the venous system included imaging of the target vessels with two-dimensional colour Doppler mapping. The diagnosis of PRUV was made in a transverse section of the fetal abdomen. Three-dimensional ultrasounds were performed as necessary, when anomalous cases were encountered. The incidence of PRUV in our population was 12/2360 = 0.5%, and it was higher than in other retrospective studies. In 75% (n = 9), PRUV was an isolated finding where delivery was uneventful and the postnatal outcome was favourable. In two cases PRUV was accompanied by omphalocele, and in one case by tetralogy of Fallot and single umbilical artery. PRUV is an uncommon prenatal finding. Screening for this anomaly can be easily performed in all pregnant patients. A diagnosis of PRUV should be followed by a thorough fetal morphology scan in order to exclude any other malformations, especially those of the cardiovascular system. © 2018 The Authors. Australian and New Zealand Journal of Obstetrics and Gynaecology published by John Wiley & Sons Australia, Ltd on behalf of Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  7. Trans-umbilical endoscopic cholecystectomy with a water-jet hybrid-knife: A pilot animal study

    PubMed Central

    Jiang, Sheng-Jun; Shi, Hong; Swar, Gyanendra; Wang, Hai-Xia; Liu, Xiao-Jing; Wang, Yong-Guang

    2013-01-01

    AIM: To investigate the feasibility and safety of Natural orifice trans-umbilical endoscopic cholecystectomy with a water-jet hybrid-knife in a non-survival porcine model. METHODS: Pure natural orifice transluminal endoscopic surgery (NOTES) cholecystectomy was performed on three non-survival pigs, by transumbilical approach, using a water-jet hybrid-knife. Under general anesthesia, the following steps detailed the procedure: (1) incision of the umbilicus followed by the passage of a double-channel flexible endsocope through an overtube into the peritoneal cavity; (2) establishment of pneumoperitoneum; (3) abdominal exploration; (4) endoscopic cholecystectomy: dissection of the gallbladder performed using water jet equipment, ligation of the cystic artery and duct conducted using nylon loops; and (5) necropsy with macroscopic evaluation. RESULTS: Transumbilical endoscopic cholecystectomy was successfully completed in the first and third pig, with minor bleedings. The dissection times were 137 and 42 min, respectively. The total operation times were 167 and 69 min, respectively. And the lengths of resected specimen were 6.5 and 6.1 cm, respectively. Instillation of the fluid into the gallbladder bed produced edematous, distended tissue making separation safe and easy. Reliable ligation using double nylon loops insured the safety of cutting between the loops. There were no intraoperative complications or hemodynamic instability. Uncontrolled introperative bleeding occurred in the second case, leading to the operation failure. CONCLUSION: Pure NOTES trans-umbilical cholecystectomy with a water-jet hybrid-knife appears to be feasible and safe. Further investigation of this technique with long-term follow-up in animals is needed to confirm the preliminary observation. PMID:24187461

  8. Trans-umbilical endoscopic cholecystectomy with a water-jet hybrid-knife: a pilot animal study.

    PubMed

    Jiang, Sheng-Jun; Shi, Hong; Swar, Gyanendra; Wang, Hai-Xia; Liu, Xiao-Jing; Wang, Yong-Guang

    2013-10-28

    To investigate the feasibility and safety of Natural orifice trans-umbilical endoscopic cholecystectomy with a water-jet hybrid-knife in a non-survival porcine model. Pure natural orifice transluminal endoscopic surgery (NOTES) cholecystectomy was performed on three non-survival pigs, by transumbilical approach, using a water-jet hybrid-knife. Under general anesthesia, the following steps detailed the procedure: (1) incision of the umbilicus followed by the passage of a double-channel flexible endoscope through an overtube into the peritoneal cavity; (2) establishment of pneumoperitoneum; (3) abdominal exploration; (4) endoscopic cholecystectomy: dissection of the gallbladder performed using water jet equipment, ligation of the cystic artery and duct conducted using nylon loops; and (5) necropsy with macroscopic evaluation. Transumbilical endoscopic cholecystectomy was successfully completed in the first and third pig, with minor bleedings. The dissection times were 137 and 42 min, respectively. The total operation times were 167 and 69 min, respectively. And the lengths of resected specimen were 6.5 and 6.1 cm, respectively. Instillation of the fluid into the gallbladder bed produced edematous, distended tissue making separation safe and easy. Reliable ligation using double nylon loops insured the safety of cutting between the loops. There were no intraoperative complications or hemodynamic instability. Uncontrolled introperative bleeding occurred in the second case, leading to the operation failure. Pure NOTES trans-umbilical cholecystectomy with a water-jet hybrid-knife appears to be feasible and safe. Further investigation of this technique with long-term follow-up in animals is needed to confirm the preliminary observation.

  9. Umbilical cord blood transplants: treatment for selected hematologic and oncologic diseases.

    PubMed

    Stevens, K

    1997-12-01

    Umbilical cord blood transplantation is a rapidly growing form of treatment for many types of cancer and hematologic disorders. The concepts behind the use of umbilical cord blood transplantation are based on information gained from experience in bone marrow transplantation. Previously discarded as human waste, the blood in the umbilical cord remnant and the placenta has been observed to be rich in hematopoietic stem cells. Techniques for collecting these stem cells from the placenta may vary among the institutions, physicians, and other health care providers, including midwives and nurse practitioners, involved with this procedure. This source of hematopoietic stem cells in transplantation has many advantages, disadvantages, and controversies associated with its use.

  10. Mathematical Model of Cardiovascular and Metabolic Responses to Umbilical Cord Occlusions in Fetal Sheep.

    PubMed

    Wang, Qiming; Gold, Nathan; Frasch, Martin G; Huang, Huaxiong; Thiriet, Marc; Wang, Xiaogang

    2015-12-01

    Fetal acidemia during labor is associated with an increased risk of brain injury and lasting neurological deficits. This is in part due to the repetitive occlusions of the umbilical cord (UCO) induced by uterine contractions. Whereas fetal heart rate (FHR) monitoring is widely used clinically, it fails to detect fetal acidemia. Hence, new approaches are needed for early detection of fetal acidemia during labor. We built a mathematical model of the UCO effects on FHR, mean arterial blood pressure (MABP), oxygenation and metabolism. Mimicking fetal experiments, our in silico model reproduces salient features of experimentally observed fetal cardiovascular and metabolic behavior including FHR overshoot, gradual MABP decrease and mixed metabolic and respiratory acidemia during UCO. Combined with statistical analysis, our model provides valuable insight into the labor-like fetal distress and guidance for refining FHR monitoring algorithms to improve detection of fetal acidemia and cardiovascular decompensation.

  11. Contribution of cardiovascular magnetic resonance in the evaluation of coronary arteries

    PubMed Central

    Mavrogeni, Sophie; Markousis-Mavrogenis, George; Kolovou, Genovefa

    2014-01-01

    Cardiovascular magnetic resonance (CMR) allows the nonradiating assessment of coronary arteries; to achieve better image quality cardiorespiratory artefacts should be corrected. Coronary MRA (CMRA) at the moment is indicated only for the detection of abnormal coronary origin, coronary artery ectasia and/or aneurysms (class I indication) and coronary bypass grafts (class II indication). CMRA utilisation for coronary artery disease is not yet part of clinical routine. However, the lack of radiation is of special value for the coronary artery evaluation in children and women. CMRA can assess the proximal part of coronary arteries in almost all cases. The best results have been observed in the evaluation of the left anterior descending and the right coronary artery, while the left circumflex, which is located far away from the coil elements, is frequently imaged with reduced quality, compared to the other two. Different studies detected an increase in wall thickness of the coronaries in patients with type I diabetes and abnormal renal function. Additionally, the non-contrast enhanced T1-weighed images detected the presence of thrombus in acute myocardial infarction. New techniques using delayed gadolinium enhanced imaging promise the direct visualization of inflamed plaques in the coronary arteries. The major advantage of CMR is the potential of an integrated protocol offering assessment of coronary artery anatomy, cardiac function, inflammation and stress perfusion-fibrosis in the same study, providing an individualized clinical profile of patients with heart disease. PMID:25349650

  12. Testing of the X-33 umbilical system at KSC

    NASA Technical Reports Server (NTRS)

    1999-01-01

    At the Launch Equipment Test Facility, , Will Reaves and Mike Solomon (kneeling), both with Lockheed Martin Technical Operations, observe parts of the X-33 umbilical system during testing. A team of Kennedy Space Center experts developed the umbilical system, comprising panels, valves and hoses that provide the means to load the X-33 with super-cold propellant. The X-33, under construction at Lockheed Martin Skunk Works in Palmdale, Calif., is a half-scale prototype of the planned operational reusable launch vehicle dubbed VentureStar.

  13. The prevalence of umbilical and epigastric hernia repair: a nationwide epidemiologic study.

    PubMed

    Burcharth, J; Pedersen, M S; Pommergaard, H-C; Bisgaard, T; Pedersen, C B; Rosenberg, J

    2015-10-01

    Umbilical and epigastric hernia repair are common surgical procedures; however, the nationwide gender and age-specific prevalence of these repairs is unknown, and this knowledge could form the basis for new studies. A nationwide register-based study covering all people living in Denmark on December 31st, 2010 was performed. Within this population all umbilical and epigastric hernia repairs from January 1st, 2006 to December 31st, 2010 were identified using data from the Danish National Hospital Register, and 5-year prevalence estimates were calculated. The study population covered 5,639,885 persons (49 % males). A total of 10,107 patients (68 % males) were operated for an umbilical hernia and 2412 patients (55 % males) were operated for an epigastric hernia. The age-specific 5-year prevalence differed for both hernia types. The highest 5-year prevalence of umbilical hernia repairs was seen in males aged 60-70 years with a 5-year prevalence of 0.53 % (95 % CI 0.51-0.56 %) and the highest age-specific 5-year prevalence of epigastric hernia repair was seen in 40-50 year females with a 5-year prevalence of 0.086 % (95 % CI 0.077-0.095 %). The gender and age-specific 5-year prevalence of umbilical and epigastric hernia repair differed in a nationwide population.

  14. Zika virus detected in amniotic fluid and umbilical cord blood in an in vitro fertilization-conceived pregnancy in Venezuela.

    PubMed

    Benjamin, Isaac; Fernández, Gissel; Figueira, José Valentin; Parpacén, Leticia; Urbina, María Teresa; Medina, Randolfo

    2017-06-01

    To describe the consequences of Zika virus infection at 10 weeks of gestation in an IVF-conceived pregnancy in Venezuela. A case report. Private assisted reproduction unit. A 36-year-old patient who conceived her first pregnancy through IVF and became infected with Zika virus at 10 weeks' gestation in Venezuela. In vitro fertilization with fresh ET. Clinical, laboratory, and imaging Zika diagnostic methods. Zika virus detection by real-time polymerase chain reaction (PCR) in maternal plasma, PCR in amniotic fluid and umbilical cord blood. Ultrasonography findings of anatomic abnormalities. Zika infection was confirmed at 10 weeks' gestation by real-time PCR; ultrasound results appeared normal. At 19 weeks' gestation, an ultrasound revealed biometry on three SDs below the means for all parameters but with no apparent anatomic abnormality. Zika virus was positive in maternal urine and amniotic fluid by PCR at 19 weeks' gestation. Ultrasound at 21 weeks + 4 days of gestation showed fetal cerebellar hypoplasia with ventricular dysmorphia, particularly marked on the left, consistent with microcephaly and ventriculomegaly. Because of the poor prognosis, pregnancy was interrupted at 24 weeks' gestation, in France. The PCR in umbilical cord blood taken in this procedure was positive for Zika virus. Initial ultrasound findings in pregnancy may not be informative. Only at 21 weeks + 4 days of gestation did an ultrasound reveal fetal microcephaly and ventriculomegaly. Combined clinical, laboratory, and imaging findings provided a complete picture of the severe damage caused by Zika infection. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  15. Experimental studies on the tensile properties of human umbilical cords.

    PubMed

    Tantius, Britta; Rothschild, Markus A; Valter, Markus; Michael, Joern; Banaschak, Sibylle

    2014-03-01

    When tried in court, mothers accused of neonaticide may claim that the umbilical cord just broke during birth and the newborn child bled to death accordingly. To evaluate the possibility of a breakage of the umbilical cord is the goal of this work. Therefore 25 umbilical cords from neonates of both sexes born at term were stretched using an electrically operated material testing machine and the energy necessary to break them was measured. This experimental set-up equals a static strain, not a dynamic one. The maximum force endured (F max) ranged from 37.24 N to 150.04 N. The average force endured was 79.87 N with a standard deviation of 27.39. The elongation at break varied from 13.24% to a maximum of 119.93%. We found no relationship between the force endured and any of the following parameters: birth weight, pH of the venous umbilical blood, diameter of cord, free length under testing, duration of pregnancy or the mother's age. We performed a literature research and tried to define the circumstances in which a break is more likely to occur, these being malformations, entanglement or disease, e.g. inflammation. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  16. Exploring the umbilical and vaginal port during minimally invasive surgery.

    PubMed

    Tinelli, Andrea; Tsin, Daniel A; Forgione, Antonello; Zorron, Ricardo; Dapri, Giovanni; Malvasi, Antonio; Benhidjeb, Tahar; Sparic, Radmila; Nezhat, Farr

    2017-09-01

    This article focuses on the anatomy, literature, and our own experiences in an effort to assist in the decision-making process of choosing between an umbilical or vaginal port. Umbilical access is more familiar to general surgeons; it is thicker than the transvaginal entry, and has more nerve endings and sensory innervations. This combination increases tissue damage and pain in the umbilical port site. The vaginal route requires prophylactic antibiotics, a Foley catheter, and a period of postoperative sexual abstinence. Removal of large specimens is a challenge in traditional laparoscopy. Recently, there has been increased interest in going beyond traditional laparoscopy by using the navel in single-incision and port-reduction techniques. The benefits for removal of surgical specimens by colpotomy are not new. There is increasing interest in techniques that use vaginotomy in multifunctional ways, as described under the names of culdolaparoscopy, minilaparoscopy-assisted natural orifice surgery, and natural orifice transluminal endoscopic surgery. Both the navel and the transvaginal accesses are safe and convenient to use in the hands of experienced laparoscopic surgeons. The umbilical site has been successfully used in laparoscopy as an entry and extraction port. Vaginal entry and extraction is associated with a lower risk of incisional hernias, less postoperative pain, and excellent cosmetic results.

  17. Umbilical Hernia Repair and Pregnancy: Before, during, after….

    PubMed

    Kulacoglu, Hakan

    2018-01-01

    Umbilical hernias are most common in women than men. Pregnancy may cause herniation or render a preexisting one apparent, because of progressively raised intra-abdominal pressure. The incidence of umbilical hernia among pregnancies is 0.08%. Surgical algorithm for a pregnant woman with a hernia is not thoroughly clear. There is no consensus about the timing of surgery for an umbilical hernia in a woman either who is already pregnant or planning a pregnancy. If the hernia is incarcerated or strangulated at the time of diagnosis, an emergency repair is inevitable. If the hernia is not complicated, but symptomatic an elective repair should be proposed. When the patient has a small and asymptomatic hernia it may be better to postpone the repair until she gives birth. If the hernia is repaired by suture alone, a high risk of recurrence exists during pregnancy. Umbilical hernia repair during pregnancy can be performed with minimal morbidity to the mother and baby. Second trimester is a proper timing for surgery. Asymptomatic hernias can be repaired, following childbirth or at the time of cesarean section (C-section). Elective repair after childbirth is possible as early as postpartum of eighth week. A 1-year interval can give the patient a very smooth convalescence, including hormonal stabilization and return to normal body weight. Moreover, surgery can be postponed for a longer time even after another pregnancy, if the patients would like to have more children. Diastasis recti are very frequent in pregnancy. It may persist in postpartum period. A high recurrence risk is expected in patients with rectus diastasis. This risk is especially high after suture repairs. Mesh repairs should be considered in this situation.

  18. [Umbilical Hernia Complicated by Gastrointestinal Stromal Tumor of the Small Intestine - A Case Report].

    PubMed

    Tsukada, Manabu; Ozaki, Akihiko; Ohira, Hiromichi; Sawano, Toyoaki; Nemoto, Tsuyoshi; Kanazawa, Yukio

    2016-11-01

    Intraabdominal tumors can cause umbilical hernia and may lead to serious consequences, such as incarcerated or necrotized intestine. However, little information is available concerning how the location and characteristics of tumors may affect the process of umbilical hernia development. A 46-year-old Japanese man presented at the department of surgery with abdominal pain and abdominal retention, which appeared on the day of presentation and 4 years before the presentation, respectively. Abdominal computed tomography revealed a suspected gastrointestinal stromal tumor(GIST)and an umbilical hernia close to the tumor, both of which were clinically diagnosed. Surgical tumor resection and hernia repair were conducted successfully. The patient was pathologically diagnosed with high-risk GIST. Adjuvant therapy with imatinib was administered with no recurrence as of 1 year post-surgery. This is a case of GIST complicated by umbilical hernia. Small solid tumors may cause umbilical hernia if they are in close proximity to vulnerable parts of the abdominal wall.

  19. Umbilical cord entanglement's frequency and its impact on the newborn.

    PubMed

    Walla, Tatjana; Rothschild, Markus A; Schmolling, Jan C; Banaschak, Sibylle

    2018-05-01

    Neonaticide is a serious allegation that needs a complete chain of criminal investigations. In this context, a nuchal cord is considered to be responsible for an infant's death, but there is a clear lack of evidence. The purpose of our study is to reveal if a nuchal cord can be responsible for stillbirth, poor perinatal outcome, or neonatal death in the forensic aspect. We conducted a prospective study in collaboration with the Augustinian Sisters' Hospital in Cologne, Germany in the period from February 2014 to May 2016. Four-hundred eighty-six children were enrolled. All births were assessed regarding the occurrence of an umbilical cord entanglement, and perinatal outcome was measured by arterial blood gas analysis, Apgar after 1, 5, and 10 min after birth as well as the general vitality. The prevalence of a nuchal cord was 16.87%. Apgar decrease and acidosis were significantly associated with a nuchal cord. No adverse perinatal outcome was recorded in this constellation. There was no child death regarding the first 24 h, and no mother experienced a syncope while giving birth. We can conclude that a nuchal cord is not associated with adverse perinatal outcome.

  20. Umbilical hernia in cirrhotic patients: outcome of elective repair.

    PubMed

    Lasheen, Adel; Naser, Hatem M; Abohassan, Ahmed

    2013-12-01

    Cirrhotic patients with umbilical hernia have an increased likelihood of complications following repair. The aim of this study was to assess the outcomes of elective umbilical hernia repair in cirrhotic patients. Fifty patients having uncomplicated umbilical hernia with a cirrhotic liver were studied prospectively. These patients divided into three groups' according to Child-Turcotte-Pugh (CTP) classification. After management of coagulopathy, correction of hypoalbuminaemia and electrolytes imbalance, and control of ascites, all patients underwent elective hernia repair under regional anesthesia. A comparison was made between the three groups as regard the size of the defect in the linea Alba, operative time, postoperative morbidity and mortality, length of hospital stay, time of return to daily life and postoperative changes in liver function tests (LFTs) in relation to the regional anesthesia applied. hernioplasty was done under spinal anesthesia in 13 patients (26%), under epidural anesthesia in 10 patients (20%), under intercostal nerve block in 7 patients (14%), and under local anesthesia in 20 patients (40%). There was an increased safety (less changes in LFTs) in cases done under local anesthesia and intercostal nerve block. The overall complications rate was 30%. There was an increased complications rate towards the decompensated cases. The differences in the mean length of hospital stay and mean time of return to daily life are statistically significant between the three groups. Umbilical hernia recurrence rate was 2% and no mortality was reported in the study groups.

  1. Concentrations of amino acids in plasma from 45- to 47-week gestation mares and foetuses (Equus caballus).

    PubMed

    Zicker, S C; Vivrette, S; Rogers, Q R

    1994-06-01

    Concentrations of 16 of 24 amino acids in plasma of foetuses were significantly higher, while four of 24 were lower, than their concentration in maternal plasma. The higher foetal concentrations of amino acids in plasma are similar to other species, with some exceptions, and suggest that equine placenta actively transports and concentrates amino acids into the umbilical circulation. Concentrations of nine of 24 amino acids were significantly lower in plasma from the umbilical artery compared to plasma from the umbilical vein, while no significant differences were present between maternal artery and vein plasma. The umbilical venous-arterial difference in concentrations of amino acids in plasma suggests the foetus extracts amino acids from the umbilical circulation for catabolism or protein synthesis, as in other species.

  2. Gross umbilical cord complications are associated with placental lesions of circulatory stasis and fetal hypoxia.

    PubMed

    Chan, Joanna S Y; Baergen, Rebecca N

    2012-01-01

    Umbilical cord complications (UCC), such as true knots (TK), velamentous (VEL) insertion, marginal umbilical cord (MUC) insertion, umbilical cord entanglement (UCE) (both nuchal and non-nuchal), excessively long umbilical cord (ELUC), and excessively twisted umbilical cord (ETUC), can lead to decreased UC blood flow and have been associated with adverse fetal outcome and intrauterine fetal demise (IUFD). Few large series exist that correlate UCC with specific pathologic findings of the placenta. We present the largest series of UCC at this time. Eight hundred forty-one 3rd-trimester placentas with UCC were identified, as well as 858 randomly selected gestational age-matched placentas with grossly unremarkable UC. Lesions associated with circulatory stasis and thrombosis, including villous capillary congestion (VC), umbilical vessel distension (UVD), chorionic plate vessel distension (CPD), umbilical vessel thrombosis (UVT), fetal vascular thrombosis (FVT), intimal fibrin cushions (IFC), and avascular villi (AV), were noted, as well as other pathologic lesions. Data were analyzed by analysis of variance and Fisher exact tests, with P < 0.05 statistically significant. Umbilical cord complications as a group was associated with a significant increase in placental circulatory stasis lesions. Lesions associated with hypoxia, namely nucleated red blood cells and chorangiosis, were also increased. Finally, the presence of any UCC was significantly associated with IUFD. We also found that multiple UCC are associated with nonreassuring fetal heart rate and chorangiosis but that the presence of a single UCC was not. This indicates that UCC may lead to intrauterine hypoxia and subsequent adverse fetal outcome and that multiple UCC may be cumulative in effect.

  3. Testing of the X-33 umbilical system at KSC

    NASA Technical Reports Server (NTRS)

    1999-01-01

    At the Launch Equipment Test Facility, Mike Solomon, with Lockheed Martin Technical Operations, studies a part of the X-33 umbilical system during testing. Pointing to the part is Will Reaves, also with Lockheed Martin Technical Operations. A team of Kennedy Space Center experts developed the umbilical system, comprising panels, valves and hoses that provide the means to load the X-33 with super-cold propellant. The X-33, under construction at Lockheed Martin Skunk Works in Palmdale, Calif., is a half-scale prototype of the planned operational reusable launch vehicle dubbed VentureStar.

  4. Testing of the X-33 umbilical system at KSC

    NASA Technical Reports Server (NTRS)

    1999-01-01

    At the Launch Equipment Test Facility, Mike Solomon (left) and Will Reaves (right), both with Lockheed Martin Technical Operations, move in for a close look at part of the X-33 umbilical system. A team of Kennedy Space Center experts developed the umbilical system, comprising panels, valves and hoses that provide the means to load the X-33 with super-cold propellant. The X-33, under construction at Lockheed Martin Skunk Works in Palmdale, Calif., is a half-scale prototype of the planned operational reusable launch vehicle dubbed VentureStar.

  5. Ethical issues in umbilical cord blood banking. Working Group on Ethical Issues in Umbilical Cord Blood Banking.

    PubMed

    Sugarman, J; Kaalund, V; Kodish, E; Marshall, M F; Reisner, E G; Wilfond, B S; Wolpe, P R

    1997-09-17

    Banking umbilical cord blood (UCB) to be used as a source of stem cells for transplantation is associated with a set of ethical issues. An examination of these issues is needed to inform public policy and to raise the awareness of prospective parents, clinicians, and investigators. Individuals with expertise in anthropology, blood banking, bone marrow transplantation, ethics, law, obstetrics, pediatrics, and the social sciences were invited to join the Working Group on Ethical Issues in Umbilical Cord Blood Banking. Members were assigned topics to present to the Working Group. Following independent reviews, background materials were sent to the Working Group. Individual presentations of topics at a 2-day meeting were followed by extensive group discussions in which consensus emerged. A writing committee then drafted a document that was circulated to the entire Working Group. After 3 rounds of comments over several months, all but 1 member of the Working Group agreed with the presentation of our conclusions. (1) Umbilical cord blood technology is promising although it has several investigational aspects; (2) during this investigational phase, secure linkage should be maintained of stored UCB to the identity of the donor; (3) UCB banking for autologous use is associated with even greater uncertainty than banking for allogeneic use; (4) marketing practices for UCB banking in the private sector need close attention; (5) more data are needed to ensure that recruitment for banking and use of UCB are equitable; and (6) the process of obtaining informed consent for collection of UCB should begin before labor and delivery.

  6. High-resolution CT evaluation of bronchial lumen to vertebral body, pulmonary artery to vertebral body and bronchial lumen to pulmonary artery ratios in Dirofilaria immitis-infected cats with and without selamectin administration.

    PubMed

    Lee-Fowler, Tekla M; Cole, Robert C; Dillon, A Ray; Graham, Shannon; Tillson, D Michael; Barney, Sharron

    2017-10-01

    Objectives The bronchial lumen to pulmonary artery (BA) ratio is utilized to evaluate pulmonary pathology on CT images. The BA ratio may be unreliable when changes are present in bronchial and pulmonary arteries concurrently. Bronchial lumen to vertebral body (BV) and pulmonary artery to vertebral body (AV) ratios have been established in normal cats and may serve as an alternative. This study aimed to evaluate the BV, AV and BA ratios in cats before and after infection with Dirofilaria immitis, with and without selamectin administration, and to characterize the distribution of disease. Methods Archived CT images were reviewed from three groups of cats: D immitis-infected untreated (n = 6); infected pretreated with selamectin (n = 6); uninfected untreated (n = 5). The BV, AV and BA ratios were calculated for all lung lobes for baseline (D0) and day 240 (D240) postinfection. Ratios and percentage change from baseline were compared between lobes and between groups. Results BV and AV ratios were more consistent in identifying abnormalities when disease was present in bronchial and arteries concurrently than BA ratios. Infected untreated cats had significant changes in both BV and AV ratios and percentage change from baseline. Abnormal BV and AV ratios were noted in the infected selamectin group, although less widely distributed. Conclusions and relevance The BV and AV ratios more accurately identified bronchial and pulmonary artery abnormalities in D immitis-infected cats. Both bronchial and pulmonary artery changes were present in infected cats, decreasing the diagnostic application of the BA ratio. Pulmonary artery changes were more widely distributed than bronchial changes in the lung. Heartworm-infected cats receiving selamectin had bronchial and pulmonary artery changes but to a lesser extent than untreated heartworm-infected cats. The CT-derived BV and AV ratios are a useful measure to evaluate lung disease of cats.

  7. Spontaneous evisceration of bowel through an umbilical hernia in a patient with refractory ascites

    PubMed Central

    Ogu, Uchechukwu Stanley; Valko, Janice; Wilhelm, Jakub; Dy, Victor

    2013-01-01

    Umbilical hernia in the cirrhotic patient is frequently seen in the setting of refractory ascites. This article reports a rare case of spontaneous rupture of a recurrent umbilical hernia in a patient with persistent ascites, following an acute increase in intra-abdominal pressure, leading to bowel evisceration. This case highlights a potentially fatal complication of umbilical hernia in the setting of chronic ascites, which was successfully managed with prompt surgical intervention. PMID:24964319

  8. Umbilical hernia rupture with evisceration of omentum from massive ascites: a case report

    PubMed Central

    2011-01-01

    Introduction The incidence of hernias is increased in patients with alcoholic liver disease with ascites. To the best of our knowledge, this is the first report of an acute rise in intra-abdominal pressure from straining for stool as the cause of a ruptured umbilical hernia. Case presentation An 81-year-old Caucasian man with a history of alcoholic liver disease presented to our emergency department with an erythematous umbilical hernia and clear, yellow discharge from the umbilicus. On straining for stool, after initial clinical assessment, our patient noted a gush of fluid and evisceration of omentum from the umbilical hernia. An urgent laparotomy was performed with excision of the umbilicus and devitalized omentum. Conclusion We report the case of a patient with a history of alcoholic liver disease with ascites. Ascites causes a chronic increase in intra-abdominal pressure. A sudden increase in intra-abdominal pressure, such as coughing, vomiting, gastroscopy or, as in this case, straining for stool can cause rupture of an umbilical hernia. The presence of discoloration, ulceration or a rapid increase in size of the umbilical hernia signals impending rupture and should prompt the physician to reduce the intra-abdominal pressure. PMID:21539740

  9. Experimenting With Baroreceptor Reflexes

    NASA Technical Reports Server (NTRS)

    Eckberg, Dwain L.; Goble, Ross L.

    1988-01-01

    Carotid arteries stimulated by pressure or suction on neck. Baro-Cuff is silicone-rubber chamber that fits on front of subject's neck. Electronic system, stepping motor, bellows, and umbilical tube furnish controlled pressure to chamber. Pressure sensor provides feedback to microprocessor in electronic system. Developed to study blood-pressure-reflex responses of astronauts in outer space. Useful for terrestrial studies of patients with congestive heart failure, chronic diabetes mellitus, and other conditions in which blood-pressure-reflex controls behave abnormally.

  10. Neonatal atrial flutter after insertion of an intracardiac umbilical venous catheter

    PubMed Central

    de Almeida, Marcos Moura; Tavares, Wládia Gislaynne de Sousa; Furtado, Maria Mônica Alencar Araripe; Fontenele, Maria Marcia Farias Trajano

    2016-01-01

    Abstract Objective: To describe a case of neonatal atrial flutter after the insertion of an intracardiac umbilical venous catheter, reporting the clinical presentation and reviewing the literature on this subject. Case description: A late-preterm newborn, born at 35 weeks of gestational age to a diabetic mother and large for gestational age, with respiratory distress and rule-out sepsis, required an umbilical venous access. After the insertion of the umbilical venous catheter, the patient presented with tachycardia. Chest radiography showed that the catheter was placed in the position that corresponds to the left atrium, and traction was applied. The patient persisted with tachycardia, and an electrocardiogram showed atrial flutter. As the patient was hemodynamically unstable, electric cardioversion was successfully applied. Comments: The association between atrial arrhythmias and misplaced umbilical catheters has been described in the literature, but in this case, it is noteworthy that the patient was an infant born to a diabetic mother, which consists in another risk factor for heart arrhythmias. Isolated atrial flutter is a rare tachyarrhythmia in the neonatal period and its identification is essential to establish early treatment and prevent systemic complications and even death. PMID:26525686

  11. Impact of anatomical parameters on optical coherence tomography retinal nerve fiber layer thickness abnormality patterns

    NASA Astrophysics Data System (ADS)

    Baniasadi, Neda; Wang, Mengyu; Wang, Hui; Jin, Qingying; Mahd, Mufeed; Elze, Tobias

    2017-02-01

    Purpose: To evaluate the effects of four anatomical parameters (angle between superior and inferior temporal retinal arteries [inter-artery angle, IAA], optic disc [OD] rotation, retinal curvature, and central retinal vessel trunk entry point location [CRVTL]) on retinal nerve fiber layer thickness (RNFLT) abnormality marks by OCT machines. Methods: Cirrus OCT circumpapillary RNFLT measurements and Humphrey visual fields (HVF 24-2) of 421 patients from a large glaucoma clinic were included. Ellipses were fitted to the OD borders. Ellipse rotation relative to the vertical axis defined OD rotation. CRVTL was manually marked on the horizontal axis of the ellipse on the OCT fundus image. IAA was calculated between manually marked retinal artery locations at the 1.73mm radius around OD. Retinal curvature was determined by the inner limiting membrane on the horizontal B-scan closest to the OD center. For each location on the circumpapillary scanning area, logistic regression was used to determine if each of the four parameters had a significant impact on RNFLT abnormality marks independent of disease severity. The results are presented on spatial maps of the entire scanning area. Results: Variations in IAA significantly influenced abnormality marks on 38.8% of the total scanning area, followed by CRVTL (19.2%) and retinal curvature (18.7%). The effect of OD rotation was negligible (<1%). Conclusions: A natural variation in IAA, retinal curvature, and CRVTL can affect OCT abnormality ratings, which may bias clinical diagnosis. Our spatial maps may help OCT manufacturers to introduce location specific norms to ensure that abnormality marks indicate ocular disease instead of variations in eye anatomy.

  12. Reappraisal of adhesive strapping as treatment for infantile umbilical hernia.

    PubMed

    Yanagisawa, Satohiko; Kato, Mototoshi; Oshio, Takehito; Morikawa, Yasuhide

    2016-05-01

    Most umbilical hernias spontaneously close by 3-5 years of age; therefore, surgical repair is considered only in children whose hernias have not closed by this point. At present, adhesive strapping is not the preferred treatment for umbilical hernias because of the lack of supporting evidence regarding its efficacy, and its association with skin complications. This aim of this study was to examine umbilical hernia closure on ultrasonography, and reassess the merits of adhesive strapping. Between January 2013 and December 2014, 89 infants underwent adhesive strapping for umbilical hernia. The strapping was changed once a week. The diameter of the hernia orifice was measured on ultrasonography every 2 weeks until closure. The closure speed (CS) of the hernia orifice was compared between the infants treated with adhesive strapping and those undergoing observation alone. The association between CS and birthweight, gestational age, diameter of the hernia orifice, and timing of treatment (before 12 weeks of age vs between 12 and 26 weeks of age) was also analyzed. Closure was achieved after 2-13 weeks of strapping in 81 infants (91%), and the likelihood of closure was not affected by the diameter of the hernia orifice, gestational age, or the timing of treatment. The mean CS of the infants treated with adhesive strapping was significantly faster than that of the infants undergoing observation alone (2.59 vs 0.37 mm/week, P < 0.05). Adhesive strapping was discontinued in five of the 89 infants (5.6%) due to severe skin complications. Adhesive strapping promoted early spontaneous umbilical hernia closure compared with observation alone, regardless of the diameter of the hernia orifice. Adhesive strapping is an effective alternative to surgery and observation. © 2015 Japan Pediatric Society.

  13. Laparoscopic management of urachal cyst associated with umbilical hernia.

    PubMed

    Gregory, G C; Vijay, R; Ligaj, M; Shiwani, M H

    2011-02-01

    The urachal cyst is a rare clinical entity of a urachal remnant. It is usually asymptomatic but can present with haematuria, tumour, urachal stone and infection. We present a case of a 63-year-old lady with a body mass index (BMI) of 49 who presented with a painful swelling in the umbilical region associated with an umbilical hernia. An ultrasound and computed tomography (CT) scan showed a suspected herniation of an umbilical remnant cyst through a paraumbilical defect. Laparoscopy confirmed the urachal cyst of 3 cm in size with a band connected with the cyst down to the urinary bladder associated with a 3-cm paraumbilical hernia. We removed the cyst and repaired the hernia laparoscopically uneventfully, after which her recovery was perfect. Radiological and laparoscopic pictures have not been reported in the English literature before. Although this condition is very rare, we suggest that it should be considered in the differential diagnosis of painful paraumbilical swelling. CT scanning and laparoscopy seems to be valuable, especially in obese patients.

  14. Low risk, but not no risk, of umbilical hernia complications requiring acute surgery in childhood.

    PubMed

    Ireland, Amanda; Gollow, Ian; Gera, Parshotam

    2014-04-01

    Umbilical hernias are a common finding in the paediatric community, with a preponderance to affect Afro-Caribbean and premature children. The rate of incarceration varies greatly between populations. Therefore, it is valuable to obtain some Australian data on this topic. We undertook a retrospective study of the records of all patients who underwent umbilical hernia repair over a 12-year period of between October 1999 and May 2012 at Princess Margaret Hospital. From this group, all patients that had an umbilical hernia repair for reason of acute complication were identified and analysed for age, ethnicity and co-morbidities. Between October 1999 and May 2012, 433 umbilical hernias were repaired at Princess Margaret Hospital, five of which were as the direct result of an acutely complicated umbilical hernia. The mean age of hernia repair was 5 years old, and the mean age of acute complication was 5 years old. Out of the patients with acutely complicated umbilical hernia, there were no Afro-Caribbean patients, and one was premature complicated by hyaline membrane disease and broncho-pulmonary dysplasia. Western Australia has an incidence of acutely complicated umbilical hernia requiring operative intervention of 1:3000 to 1:11,000. On an international scale, this is low, and studies with similar incidence do not advocate for immediate repair of all identified umbilical hernias. The authors believe repair should be guided by patient and guardian, but if there is an episode of incarceration, acute repair is advised. © 2013 The Authors. Journal of Paediatrics and Child Health © 2013 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  15. Umbilical Hernia Repair and Pregnancy: Before, during, after…

    PubMed Central

    Kulacoglu, Hakan

    2018-01-01

    Umbilical hernias are most common in women than men. Pregnancy may cause herniation or render a preexisting one apparent, because of progressively raised intra-abdominal pressure. The incidence of umbilical hernia among pregnancies is 0.08%. Surgical algorithm for a pregnant woman with a hernia is not thoroughly clear. There is no consensus about the timing of surgery for an umbilical hernia in a woman either who is already pregnant or planning a pregnancy. If the hernia is incarcerated or strangulated at the time of diagnosis, an emergency repair is inevitable. If the hernia is not complicated, but symptomatic an elective repair should be proposed. When the patient has a small and asymptomatic hernia it may be better to postpone the repair until she gives birth. If the hernia is repaired by suture alone, a high risk of recurrence exists during pregnancy. Umbilical hernia repair during pregnancy can be performed with minimal morbidity to the mother and baby. Second trimester is a proper timing for surgery. Asymptomatic hernias can be repaired, following childbirth or at the time of cesarean section (C-section). Elective repair after childbirth is possible as early as postpartum of eighth week. A 1-year interval can give the patient a very smooth convalescence, including hormonal stabilization and return to normal body weight. Moreover, surgery can be postponed for a longer time even after another pregnancy, if the patients would like to have more children. Diastasis recti are very frequent in pregnancy. It may persist in postpartum period. A high recurrence risk is expected in patients with rectus diastasis. This risk is especially high after suture repairs. Mesh repairs should be considered in this situation. PMID:29435451

  16. Cardiac tamponade due to umbilical venous catheter in the new born

    PubMed Central

    Abdellatif, Mohamed; Ahmed, Ashfag; Alsenaidi, Khalfan

    2012-01-01

    With more and more extreme premature and very low-birth weight babies being resuscitated, umbilical central venous catheterisation is now being used more frequently in neonatal intensive care. The authors present a case of cardiac tamponade following umbilical venous catheterisation in a neonate, an uncommon, yet potentially fatal complication. The patient was diagnosed at the appropriate time by echocardiography and urgent pericardiocentesis proved lifesaving. PMID:22802560

  17. Arterial wave reflection and subclinical left ventricular systolic dysfunction.

    PubMed

    Russo, Cesare; Jin, Zhezhen; Takei, Yasuyoshi; Hasegawa, Takuya; Koshaka, Shun; Palmieri, Vittorio; Elkind, Mitchell Sv; Homma, Shunichi; Sacco, Ralph L; Di Tullio, Marco R

    2011-03-01

    Increased arterial wave reflection is a predictor of cardiovascular events and has been hypothesized to be a cofactor in the pathophysiology of heart failure. Whether increased wave reflection is inversely associated with left-ventricular (LV) systolic function in individuals without heart failure is not clear. Arterial wave reflection and LV systolic function were assessed in 301 participants from the Cardiovascular Abnormalities and Brain Lesions (CABL) study using two-dimensional echocardiography and applanation tonometry of the radial artery to derive central arterial waveform by a validated transfer function. Aortic augmentation index (AIx) and wasted energy index (WEi) were used as indices of wave reflection. LV systolic function was measured by LV ejection fraction (LVEF) and tissue Doppler imaging (TDI). Mitral annulus peak systolic velocity (Sm), peak longitudinal strain and strain rate were measured. Participants with history of coronary artery disease, atrial fibrillation, LVEF less than 50% or wall motion abnormalities were excluded. Mean age of the study population was 68.3 ± 10.2 years (64.1% women, 65% hypertensive). LV systolic function by TDI was lower with increasing wave reflection, whereas LVEF was not. In multivariate analysis, TDI parameters of LV longitudinal systolic function were significantly and inversely correlated to AIx and WEi (P values from 0.05 to 0.002). In a community cohort without heart failure and with normal LVEF, an increased arterial wave reflection was associated with subclinical reduction in LV systolic function assessed by novel TDI techniques. Further studies are needed to investigate the prognostic implications of this relationship.

  18. Safety and effectiveness of umbilical hernia repair in patients with cirrhosis.

    PubMed

    Hew, S; Yu, W; Robson, S; Starkey, G; Testro, A; Fink, M; Angus, P; Gow, P

    2018-03-27

    Umbilical hernia is a common complication in patients with cirrhosis. Early studies have reported a high morbidity and mortality associated with hernia repair. The traditional approach has been to non-operatively manage umbilical hernias in patients with cirrhosis. There are emerging data suggesting that an elective repair is a preferable approach. This study examined the outcomes of umbilical hernia repair in patients with advanced liver disease and compared this with a control group of non-cirrhotic patients. Prospective data were collected regarding the outcome of umbilical hernia repairs performed between 2004 and 2013 at the Austin Hospital, Melbourne, Australia. Outcomes at 90 days were compared between patients with and without cirrhosis. 79 patients with cirrhosis and 249 controls were analysed. Of the patients with cirrhosis, 9% were classified as Child-Pugh A, 61% were Child-Pugh B and 30% were Child-Pugh C. Emergency repairs for complicated hernias was undertaken in 18% of the cirrhosis population and 10% in controls (P = 0.10). Post-operative complications occurred more commonly in patients with cirrhosis (26%) compared with controls (11%) (P < 0.01). Emergency hernia repairs were associated with a higher complication rate in both patients with cirrhosis (62%) and controls (20%) (P = 0.01). There was no significant difference in the rate of hernia recurrence as assessed by clinical examination between patients with cirrhosis (2.7%) and controls (6.8%) (P = 0.17) nor in 90-day mortality between patients with cirrhosis (n = 1, 1.3%) and the controls (n = 0) (P = 0.43). Within the limitations of a small study cohort and therefore an underpowered study, elective surgical repair of umbilical hernias in patients with cirrhosis, including decompensated cirrhosis, may not be associated with a significant increase in mortality when compared to a control cohort. Whilst complications are higher in cirrhotic patients, there is no

  19. Long-term follow-up results of umbilical hernia repair.

    PubMed

    Venclauskas, Linas; Jokubauskas, Mantas; Zilinskas, Justas; Zviniene, Kristina; Kiudelis, Mindaugas

    2017-12-01

    Multiple suture techniques and various mesh repairs are used in open or laparoscopic umbilical hernia (UH) surgery. To compare long-term follow-up results of UH repair in different hernia surgery groups and to identify risk factors for UH recurrence. A retrospective analysis of 216 patients who underwent elective surgery for UH during a 10-year period was performed. The patients were divided into three groups according to surgery technique (suture, mesh and laparoscopic repair). Early and long-term follow-up results including hospital stay, postoperative general and wound complications, recurrence rate and postoperative patient complaints were reviewed. Risk factors for recurrence were also analyzed. One hundred and forty-six patients were operated on using suture repair, 52 using open mesh and 18 using laparoscopic repair technique. 77.8% of patients underwent long-term follow-up. The postoperative wound complication rate and long-term postoperative complaints were significantly higher in the open mesh repair group. The overall hernia recurrence rate was 13.1%. Only 2 (1.7%) patients with small hernias (< 2 cm) had a recurrence in the suture repair group. Logistic regression analysis showed that body mass index (BMI) > 30 kg/m 2 , diabetes and wound infection were independent risk factors for umbilical hernia recurrence. The overall umbilical hernia recurrence rate was 13.1%. Body mass index > 30 kg/m 2 , diabetes and wound infection were independent risk factors for UH recurrence. According to our study results, laparoscopic medium and large umbilical hernia repair has slight advantages over open mesh repair concerning early postoperative complications, long-term postoperative pain and recurrence.

  20. Active Vibration Isolation of Microgravity Experiments with Spring Umbilicals Using an Electrodynamic Actuator

    NASA Technical Reports Server (NTRS)

    Banerjee, B. B.; Allaire, P. E.; Grodsinsky, C. M.

    1996-01-01

    Microgravity experiments will require active vibration isolation in the low to mid frequency range of 0.1 Hz to 10 Hz. Approximately two orders of acceleration reduction (40 dB) will be required. Previous works have reported results for accelerations transmitted through the umbilical. This paper describes experimental and theoretical results for vibration isolation in one dimension (horizontal) where the simulated experiment is connected to the spacecraft by a spring umbilical. The experiment consisted of a spacecraft (shaker), experiment (mass), umbilical, accelerometer, control electronics, and Lorentz actuator. The experiment mass was supported in magnetic bearings to avoid any stiction problems. Acceleration feedback control was employed to obtain the vibration isolation. Three different spring umbilicals were employed. Acceleration reductions on the order of 40 dB were obtained over the frequency range of 0.1 Hz to 10 Hz. Good agreement was obtained between theory and experiment.

  1. The conception, birth, and growth of a missile umbilical system

    NASA Technical Reports Server (NTRS)

    Nordman, G. W.

    1977-01-01

    The design development was traced for the sprint 2 and improved sprint 2 missile system (ISMS) umbilical system. The unique system requirements, umbilical designs considered to meet the requirements, and the problems encountered and solutions derived during the design, and development testing of the selected systems are described. The sprint 2 development effort consisted of design, analysis, and testing activities. The ISMS effort involved the performance of an extensive trade study to determine the optimum design to meet the ISMS conditions.

  2. Extending the Capability of Mars Umbilical Technology Demonstrator

    NASA Technical Reports Server (NTRS)

    Houshangi, Nasser

    2001-01-01

    The objective of this project is to expand the capabilities of for the Mars Umbilical Technology Demonstrator (MUTD). The MUTD shall provide electrical power and fiber optic data cable connections between two simulated mars vehicles, 1000 in apart. ne wheeled mobile robot Omnibot is used to provide the mobile base for the system. The mate-to umbilical plate is mounted on a Cartesian robot, which is installed on the Omnibot mobile base. It is desirable to provide the operator controlling the Omnibot, the distance and direction to the target. In this report, an approach for finding the position and orientation of the mobile robot using inertial sensors and beacons is investigated. First phase of the project considered the Omnibot being on the flat surface. To deal with the uneven Mars environment, the orientation as well as position needs to be controlled. During local positioning, the information received from four ultrasonic sensors installed at the four corner of the mate-mi plate is used to identify the position of mate-to plate and mate the umbilical plates autonomously. The work proposed is the continuation of the principal investigator research effort as a participant in the 1999 NASA/ASEE Summer Faculty Fellowship Program.

  3. Sonographic diagnosis of hepatic erosion caused by umbilical catheterization.

    PubMed

    Schiavone, R; Narese, D; Ognibene, N; Rossi, E; Antonello, M; Basile, M; Di Maurizio, M; Defilippi, C

    2016-01-01

    The use of umbilical venous catheter (UVC) is common practice in neonatal units. The traumatic injury of the hepatic parenchyma is a rare complication. We present a case of a preterm newborn underwent ultrasound examination revealing a hyperechogenic focal lesion at the confluence of the hepatic veins This finding, according to patient's history, was suspected to be a traumatic injury of the liver parenchyma caused by umbilical catheterization. During sonographic follow-up this lesion gradually reduced until complete resolution. Finally, when focal hyperechogenic hepatic lesion is incidentally detected in newborn with history of UVC placement, the radiologists must consider the traumatic etiology.

  4. Attitudes of Swiss mothers toward unrelated umbilical cord blood banking 6 months after donation.

    PubMed

    Danzer, Enrico; Holzgreve, Wolfgang; Troeger, Carolyn; Kostka, Ulrike; Steimann, Sabine; Bitzer, Johanes; Gratwohl, Alois; Tichelli, André; Seelmann, Kurt; Surbek, Daniel V

    2003-05-01

    During the past decade, the use of umbilical cord blood (CB) as a source of transplantable hematopoietic stem cells has been increasing. Little is known about the psychosocial consequences that later affect parents after unrelated CB donation. The objective of this study was to evaluate the attitudes of mothers toward unrelated donation of umbilical CB for transplantation 6 months after giving birth. A prospective study was performed with a standardized, anonymous questionnaire distributed to 131 women 6 months after CB donation. The questionnaire included topics concerning views about the ethical accuracy of having donated CB, emotional responses after donation, concerns about genetic testing and research with CB samples, attitude toward anonymity between her child and possible unrelated CB recipient, and willingness to repeatedly donate umbilical CB in a next pregnancy. The vast majority (96.1%) stated that they would donate umbilical CB again, and all respondents were certain that their decision to have donated umbilical CB was ethical. With regard to the potential risks of genetic testing and "experimentation" of umbilical CB, a significant correlation (p = 0.01) was found between negative attitudes and the decision not to donate umbilical CB again. Additionally, it was observed that women who had a negative experience concerning the donation of CB would not donate again (p = 0.004). This study shows a high degree of satisfaction of unrelated umbilical CB donation for banking in women 6 months after delivery. Despite a well-performed and detailed informed consent procedure, one of the ongoing issues for the donators in CB banking involves the concern regarding of improper use of the cells, such as genetic testing or experimentation. Accurate and detailed counseling of pregnant women and their partners therefore maximizes the likelihood that they will donate CB for unrelated banking. These data provide a basis for the improvement of donor selection procedures

  5. Umbilical hernia repair in pregnant patients: review of the American College of Surgeons National Surgical Quality Improvement Program.

    PubMed

    Haskins, I N; Rosen, M J; Prabhu, A S; Amdur, R L; Rosenblatt, S; Brody, F; Krpata, D M

    2017-10-01

    Umbilical hernias present commonly during pregnancy secondary to increased intra-abdominal pressure. As a result, umbilical hernia incarceration or strangulation may affect pregnant females. The purpose of this study is to detail the operative management and 30-day outcomes of umbilical hernias in pregnant patients using the American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP). All female patients undergoing umbilical hernia repair during pregnancy were identified within the ACS-NSQIP. Preoperative patient variables, intraoperative variables, and 30-day patient morbidity and mortality outcomes were investigated using a variety of statistical tests. A total of 126 pregnant patients underwent umbilical hernia repair from 2005 to 2014; 73 (58%) had incarceration or strangulation at the time of surgical intervention. The majority of patients (95%) underwent open umbilical hernia repair. Superficial surgical site infection was the most common morbidity in patients undergoing open umbilical hernia repair. Based on review of the ACS-NSQIP database, the incidence of umbilical hernia repair during pregnancy is very low; however, the majority of patients required repair for incarceration of strangulation. When symptoms develop, these hernias can be repaired with minimal 30-day morbidity to the mother. Additional studies are needed to determine the long-term recurrence rate of umbilical hernia repairs performed in pregnant patients and the effects of surgical intervention and approach on the fetus.

  6. Flood Syndrome: Spontaneous Umbilical Hernia Rupture Leaking Ascitic Fluid-A Case Report.

    PubMed

    Nguyen, Emilie T; Tudtud-Hans, Leah A

    2017-01-01

    We report a rare case of Flood syndrome, which is a spontaneous rupture of an umbilical hernia. A 42-year-old man with decompensated hepatitis C and alcoholic cirrhosis complicated by ascites and esophageal varices presented with 1 day of ascitic fluid drainage after rupture of a preexisting umbilical hernia associated with diffuse abdominal pain and tenderness. A pigtail drain was placed in the right upper abdominal quadrant to decrease fluid drainage from the abdominal wall defect, allowing it to heal naturally. The spontaneous rupture of an umbilical hernia in our patient highlights a rare complication with high mortality rates and stresses the challenge of treatment that falls in the area between medical and surgical management.

  7. Current obstetrical practice and umbilical cord prolapse.

    PubMed

    Usta, I M; Mercer, B M; Sibai, B M

    1999-01-01

    The aim of this study was to assess the contribution of current obstetrical practice to the occurrence and complications of umbilical cord prolapse. Maternal and neonatal charts of 87 pregnancies complicated by true umbilical cord prolapse during a 5-year period were reviewed. Twin gestation and noncephalic presentations were common features (14 and 41%, respectively). Eighty-nine percent (77) of infants were delivered by cesarean section of which 29% were classical and 88% were primary. The mean gestational age at delivery was 34.0 +/- 6.0 weeks, and the mean birth weight was 2318 +/- 1159 g. Obstetrical intervention preceded 41 (47%) cases (the obstetrical intervention group): amniotomy (9), scalp electrode application (4), intrauterine pressure catheter insertion (6), attempted external cephalic version (7), expectant management of preterm premature rupture of membranes (14), manual rotation of the fetal head (1), and amnioreduction (1). There were 11 perinatal deaths. Thirty-three percent of the infants (32) had a 5-min Apgar score < 7 and 34% had a cord pH < 7.20. Neonatal seizures, intracerebral hemorrhage, necrotizing enterocolitis, hyaline membrane disease, persistent fetal circulation, sepsis, assisted ventilation, and perinatal mortality were comparable in the "obstetrical intervention" and "no-intervention" groups. Most of the neonatal complications occurred in infants < 32 weeks' gestation. We conclude that obstetrical intervention contributes to 47% of umbilical cord prolapse cases; however, it does not increase the associated perinatal morbidity and mortality.

  8. Epidemiological and Clinical Characteristics of Kawasaki Disease and Factors Associated with Coronary Artery Abnormalities in East China: Nine Years Experience

    PubMed Central

    Tang, Yunjia; Gao, Xiang; Shen, Jie; Sun, Ling

    2016-01-01

    Background: Because of the different genetic backgrounds, living environments and economic conditions, the epidemiologic, clinical characteristics and risk factors for coronary artery abnormalities (CAAs) in the Chinese population may differ among different parts of China. Methods: We did a retrospective study to explore the clinical characteristics and risk factors for CAAs in east China between 2006 and 2014. Results: There were 1016 patients during the study period. Of the 1004 patients who completed echocardiographic studies, 23.9% had CAAs. Sex, serum albumin, erythrocyte sedimentation rate (ESR), Mycoplasma pneumoniae (MP) infection, intravenous immunoglobulin (IVIG) started after the 10th day of illness and IVIG non-responders were independent risk factors associated with CAA. Conclusions: East China has a lower incidence of CAAs compared with southwest and northeast China, while similar to north China. Male gender, serum albumin, ESR, MP infection, IVIG started after the 10th day of illness and IVIG non-responders were predictive of CAA. PMID:26884440

  9. pitx2 Deficiency Results in Abnormal Ocular and Craniofacial Development in Zebrafish

    PubMed Central

    Liu, Yi; Semina, Elena V.

    2012-01-01

    Human PITX2 mutations are associated with Axenfeld-Rieger syndrome, an autosomal-dominant developmental disorder that involves ocular anterior segment defects, dental hypoplasia, craniofacial dysmorphism and umbilical abnormalities. Characterization of the PITX2 pathway and identification of the mechanisms underlying the anomalies associated with PITX2 deficiency is important for better understanding of normal development and disease; studies of pitx2 function in animal models can facilitate these analyses. A knockdown of pitx2 in zebrafish was generated using a morpholino that targeted all known alternative transcripts of the pitx2 gene; morphant embryos generated with the pitx2ex4/5 splicing-blocking oligomer produced abnormal transcripts predicted to encode truncated pitx2 proteins lacking the third (recognition) helix of the DNA-binding homeodomain. The morphological phenotype of pitx2ex4/5 morphants included small head and eyes, jaw abnormalities and pericardial edema; lethality was observed at ∼6–8-dpf. Cartilage staining revealed a reduction in size and an abnormal shape/position of the elements of the mandibular and hyoid pharyngeal arches; the ceratobranchial arches were also decreased in size. Histological and marker analyses of the misshapen eyes of the pitx2ex4/5 morphants identified anterior segment dysgenesis and disordered hyaloid vasculature. In summary, we demonstrate that pitx2 is essential for proper eye and craniofacial development in zebrafish and, therefore, that PITX2/pitx2 function is conserved in vertebrates. PMID:22303467

  10. The changes in Doppler indices of fetal ductus venosus and umbilical artery after amnioinfusion for women with preterm premature rupture of membranes before 26 weeks' gestation.

    PubMed

    Hsu, Te-Yao; Hsu, Jenn-Jeih; Fu, Hung-Chun; Ou, Chia-Yu; Tsai, Chih-Chang; Cheng, Bi-Hua; Fang, Fu-Min; Kao, Hui-Fen; Yang, Chun-Yuh; Tsai, Wen Lin; Sung, Chuen Chu; Tsai, Men-Yi

    2009-09-01

    To investigate the changes in Doppler indices of the fetal ductus venosus (DV) and umbilical artery (UMA) after amnioinfusion in pregnant women with preterm premature rupture of membranes (pPROM). Pregnancies with pPROM and severe oligohydramnios cause sequelae in newborns and mothers. This cross-sectional study included a group of 25 patients with pPROM before 26 weeks' gestation. Color Doppler imaging was used to measure the impedance index and quantitative blood flow in the DV and systolic/diastolic ratio (S/D) of the UMA before and 30 minutes after the end of amnioinfusion. The following velocity parameters were measured: (1) DV peak systolic velocity; (2) DV time-averaged velocity; (3) DV maximum forward velocity during atrial contraction; (4) DV S/D; (5) DV pulsatility index (PI); (6) DV Pourcelots resistance index (RI); (7) fetal heart rate; and (8) UMA S/D. Twenty-one of the 25 patients underwent a total of 27 amnioinfusions. The mean PI and RI of the DV, and S/D of the DV and UMA decreased significantly after amnioinfusion (PI, 0.75 +/- 0.24 vs. 0.60 +/- 0.18, p = 0.009; RI, 0.60 +/- 0.15 vs. 0.50 +/- 0.13; DV S/D, 3.07 +/- 1.81 vs. 2.13 +/- 0.66, p = 0.008; UMA S/D, 3.58 +/- 0.87 vs. 2.88 +/- 0.62, p = 0.001). Amnioinfusion increases the space for the fetuses and reduces the impedance of the fetoplacental circulation. Improvements in DV and UMA flow may benefit fetuses suffering severe oligohydramnios in mid-pregnancy.

  11. Transplantation of cryopreserved human umbilical cord blood mononuclear cells does not induce sustained recovery after experimental stroke in spontaneously hypertensive rats

    PubMed Central

    Weise, Gesa; Lorenz, Marlene; Pösel, Claudia; Maria Riegelsberger, Ute; Störbeck, Veronika; Kamprad, Manja; Kranz, Alexander; Wagner, Daniel-Christoph; Boltze, Johannes

    2014-01-01

    Previous studies have highlighted the enormous potential of cell-based therapies for stroke not only to prevent ischemic brain damage, but also to amplify endogenous repair processes. Considering its widespread availability and low immunogenicity human umbilical cord blood (HUCB) is a particularly attractive stem cell source. Our goal was to investigate the neurorestorative potential of cryopreserved HUCB mononuclear cells (MNC) after permanent middle cerebral artery occlusion (MCAO) in spontaneously hypertensive rats (SHR). Human umbilical cord blood MNC or vehicle solution was administered intravenously 24 hours after MCAO. Experimental groups were as follows: (1) quantitative polymerase chain reaction (PCR) of host-derived growth factors up to 48 hours after stroke; (2) immunohistochemical analysis of astroglial scarring; (3) magnetic resonance imaging (MRI) and weekly behavioral tests for 2 months after stroke. Long-term functional outcome and lesion development on MRI were not beneficially influenced by HUCB MNC therapy. Furthermore, HUCB MNC treatment did not change local growth factor levels and glial scarring extent. In summary, we could not demonstrate neurorestorative properties of HUCB MNC after stroke in SHR. Our results advise caution regarding a prompt translation of cord blood therapy into clinical stroke trials as long as deepened knowledge about its precise modes of action is missing. PMID:24169850

  12. Evolution of congenital malformations of the umbilical-portal-hepatic venous system.

    PubMed

    Scalabre, Aurelien; Gorincour, Guillaume; Hery, Geraldine; Gamerre, Marc; Guys, Jean-Michel; de Lagausie, Pascal

    2012-08-01

    The objective of this study is to describe the evolution of 8 cases of congenital malformations of the umbilical-portal-hepatic venous system diagnosed before the first month of life. All cases of congenital malformation of the portal and hepatic venous system diagnosed prenatally or during the first month of life in our institution were systematically reviewed since November 2000. Clinical features, imaging, and anatomical findings were reviewed, focusing primarily on clinical and radiologic evolution. Eight cases of congenital malformation of the umbilical-portal-hepatic venous system were studied. Fifty percent of these malformations were diagnosed prenatally. We report 4 portosystemic shunts. Three involuted spontaneously, and the fourth one required surgical treatment. We report a variation of the usual anatomy of portal and hepatic veins that remained asymptomatic, an aneurysmal dilatation of a vitelline vein causing portal vein thrombosis that needed prompt surgical treatment with good result, a complex portal and hepatic venous malformation treated operatively, and a persistent right umbilical vein that remained asymptomatic. Prenatal diagnosis of malformations of the umbilical-portal-hepatic venous network is uncommon. Little is known about the postnatal prognosis. Clinical, biologic, and radiologic follow-up by ultrasonography is essential to distinguish pathologic situations from normal anatomical variants. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Peripheral Endothelial Function After Arterial Switch Operation for D-looped Transposition of the Great Arteries.

    PubMed

    Sun, Heather Y; Stauffer, Katie Jo; Nourse, Susan E; Vu, Chau; Selamet Tierney, Elif Seda

    2017-06-01

    Coronary artery re-implantation during arterial switch operation in patients with D-looped transposition of the great arteries (D-TGA) can alter coronary arterial flow and increase shear stress, leading to local endothelial dysfunction, although prior studies have conflicting results. Endothelial pulse amplitude testing can predict coronary endothelial dysfunction by peripheral arterial testing. This study tested if, compared to healthy controls, patients with D-TGA after arterial switch operation had peripheral endothelial dysfunction. Patient inclusion criteria were (1) D-TGA after neonatal arterial switch operation; (2) age 9-29 years; (3) absence of known cardiovascular risk factors such as hypertension, diabetes, hypercholesterolemia, vascular disease, recurrent vasovagal syncope, and coronary artery disease; and (4) ability to comply with overnight fasting. Exclusion criteria included (1) body mass index ≥85th percentile, (2) use of medications affecting vascular tone, or (3) acute illness. We assessed endothelial function by endothelial pulse amplitude testing and compared the results to our previously published data in healthy controls (n = 57). We tested 20 D-TGA patients (16.4 ± 4.8 years old) who have undergone arterial switch operation at a median age of 5 days (0-61 days). Endothelial pulse amplitude testing indices were similar between patients with D-TGA and controls (1.78 ± 0.61 vs. 1.73 ± 0.54, p = 0.73).In our study population of children and young adults, there was no evidence of peripheral endothelial dysfunction in patients with D-TGA who have undergone arterial switch operation. Our results support the theory that coronary arterial wall thickening and abnormal vasodilation reported in these patients is a localized phenomenon and not reflective of overall atherosclerotic burden.

  14. Salivary glands abnormalities in oculo-auriculo-vertebral spectrum.

    PubMed

    Brotto, Davide; Manara, Renzo; Vio, Stefania; Ghiselli, Sara; Cantone, Elena; Mardari, Rodica; Toldo, Irene; Stritoni, Valentina; Castiglione, Alessandro; Lovo, Elisa; Trevisi, Patrizia; Bovo, Roberto; Martini, Alessandro

    2018-01-01

    Feeding and swallowing impairment are present in up to 80% of oculo-auriculo-vertebral spectrum (OAVS) patients. Salivary gland abnormalities have been reported in OAVS patients but their rate, features, and relationship with phenotype severity have yet to be defined. Parotid and submandibular salivary gland hypo/aplasia was evaluated on head MRI of 25 OAVS patients (16 with severe phenotype, Goldenhar syndrome) and 11 controls. All controls disclosed normal salivary glands. Abnormal parotid glands were found exclusively ipsilateral to facial microsomia in 21/25 OAVS patients (84%, aplasia in six patients) and showed no association with phenotype severity (14/16 patients with Goldenhar phenotype vs 7/9 patients with milder phenotype, p = 0.6). Submandibular salivary gland hypoplasia was detected in six OAVS patients, all with concomitant ipsilateral severe involvement of the parotid gland (p < 0.001). Submandibular salivary gland hypoplasia was associated to Goldenhar phenotype (p < 0.05). Parotid gland abnormalities were associated with ipsilateral fifth (p < 0.001) and seventh cranial nerve (p = 0.001) abnormalities. No association was found between parotid gland anomaly and ipsilateral internal carotid artery, inner ear, brain, eye, or spine abnormalities (p > 0.6). Salivary gland abnormalities are strikingly common in OAVS. Their detection might help the management of OAVS-associated swallowing and feeding impairment.

  15. Endometriosis of umbilical cicatrix: case report and review of the literature.

    PubMed

    Rosina, Paolo; Pugliarello, Silvia; Colato, Chiara; Girolomoni, Giampiero

    2008-01-01

    Umbilical endometriosis has an estimated incidence of 0.5%-1% of all patients with endometrial ectopia. It is a very rare disease, but should be considered on the differential diagnosis of umbilical lesions. We report on a case of spontaneous umbilical endometriosis in a 38-year-old woman, with a dark brown nodule periodically bleeding, associated with severe abdominal pain. There was no history of endometriosis and she had not been pregnant before. Laparoscopic visualization of pelvic cavity showed bilateral ovarian endometrioma (it was removed while sparing the ovaries). Surgical treatment proved effective. Cutaneous endometriosis could be a sign of internal endometriosis. Presentations may be atypical and pose diagnostic difficulty, mimicking other acute diseases, e.g., skin neoplasm, folliculitis, etc., but it should be suspected in any female presenting with a painful or bleeding mass close to the umbilicus or abdominal surgical scar.

  16. Abnormal Glucose Metabolism and High-Energy Expenditure in Idiopathic Pulmonary Arterial Hypertension

    PubMed Central

    Malin, Steven K.; Barnes, Jarrod W.; Tian, Liping; Kirwan, John P.; Dweik, Raed A.

    2017-01-01

    Rationale: Insulin resistance has emerged as a potential mechanism related to the pathogenesis of idiopathic pulmonary arterial hypertension (IPAH). However, direct measurements of insulin and glucose metabolism have not been performed in patients with IPAH to date. Objectives: To perform comprehensive metabolic phenotyping of humans with IPAH. Methods: We assessed plasma insulin and glucose, using an oral glucose tolerance test and estimated insulin resistance, and β-cell function in 14 patients with IPAH and 14 control subjects matched for age, sex, blood pressure, and body mass index. Body composition (dual-energy X-ray absorptiometry), inflammation (CXC chemokine ligand 10, endothelin-1), physical fitness (6-min walk test), and energy expenditure (indirect calorimetry) were also assessed. Measurements and Main Results: Patients with IPAH had a higher rate of impaired glucose tolerance (57 vs. 14%; P < 0.05) and reduced glucose-stimulated insulin secretion compared with matched control subjects (IPAH: 1.31 ± 0.76 μU/ml⋅mg/dl vs. control subjects: 2.21 ± 1.27 μU/ml⋅mg/dl; P < 0.05). Pancreatic β-cell function was associated with circulating endothelin-1 (r = –0.71, P < 0.01) and CXC chemokine ligand 10 (r = –0.56, P < 0.05). Resting energy expenditure was elevated in IPAH (IPAH: 32 ± 3.4 vs. control subjects: 28.8 ± 2.9 kcal/d/kg fat-free mass; P < 0.05) and correlated with the plasma glucose response (r = 0.51, P < 0.01). Greater insulin resistance was associated with reduced 6-minute walk distance (r = 0.55, P < 0.05). Conclusions: Independent of age, sex, blood pressure, and body mass index, patients with IPAH have glucose intolerance, decreased insulin secretion in response to glucose, and elevated resting energy expenditure. These abnormalities are associated with circulating markers of inflammation and vascular dysfunction. PMID:27922752

  17. Good practices in collecting umbilical cord and placental blood.

    PubMed

    Lopes, Lauren Auer; Bernardino, Elizabeth; Crozeta, Karla; Guimarães, Paulo Ricardo Bittencourt

    2016-08-18

    to identify the factors related to the quality of umbilical cord and placental blood specimens, and define best practices for their collection in a government bank of umbilical cord and placental blood. this was a descriptive study, quantitative approach, performed at a government umbilical cord and placental blood bank, in two steps: 1) verification of the obstetric, neonatal and operational factors, using a specific tool for gathering data as non-participant observers; 2) definition of best practices by grouping non-conformities observed before, during and after blood collection. The data was analyzed using descriptive statistics and the following statistical software: Statistica(r) and R(r). while there was a correlation with obstetrical and neonatal factors, there was a larger correlation with operational factors, resulting in the need to adjust the professional practices of the nursing staff and obstetrical team involved in collecting this type of blood. Based on these non-conformities we defined best practices for nurses before, during and after blood collection. the best practices defined in this study are an important management tool for the work of nurses in obtaining blood specimens of high cell quality. identificar fatores relacionados à qualidade das amostras do sangue de cordão umbilical e placentário e definir boas práticas para sua coleta em um banco público de sangue de cordão umbilical e placentário. pesquisa descritiva, abordagem quantitativa, realizada em um banco público de sangue de cordão umbilical e placentário, desenvolvida em duas etapas: 1) verificação dos fatores obstétricos, neonatais e operacionais, obtidos por coleta em instrumento próprio e observação não participante; 2) definição das boas práticas, por meio do agrupamento de não-conformidades observadas antes, durante e após a coleta do sangue. Os dados foram analisados por meio da estatística descritiva, utilizando-se dos softwares Statistica(r) e R(r). houve

  18. Microvascular and Macrovascular Abnormalities and Cognitive and Physical Function in Older Adults: Cardiovascular Health Study.

    PubMed

    Kim, Dae Hyun; Grodstein, Francine; Newman, Anne B; Chaves, Paulo H M; Odden, Michelle C; Klein, Ronald; Sarnak, Mark J; Lipsitz, Lewis A

    2015-09-01

    To evaluate and compare the associations between microvascular and macrovascular abnormalities and cognitive and physical function Cross-sectional analysis of the Cardiovascular Health Study (1998-1999). Community. Individuals with available data on three or more of five microvascular abnormalities (brain, retina, kidney) and three or more of six macrovascular abnormalities (brain, carotid artery, heart, peripheral artery) (N = 2,452; mean age 79.5). Standardized composite scores derived from three cognitive tests (Modified Mini-Mental State Examination, Digit-Symbol Substitution Test, Trail-Making Test (TMT)) and three physical tests (gait speed, grip strength, 5-time sit to stand) Participants with high microvascular and macrovascular burden had worse cognitive (mean score difference = -0.30, 95% confidence interval (CI) = -0.37 to -0.24) and physical (mean score difference = -0.32, 95% CI = -0.38 to -0.26) function than those with low microvascular and macrovascular burden. Individuals with high microvascular burden alone had similarly lower scores than those with high macrovascular burden alone (cognitive function: -0.16, 95% CI = -0.24 to -0.08 vs -0.13, 95% CI = -0.20 to -0.06; physical function: -0.15, 95% CI = -0.22 to -0.08 vs -0.12, 95% CI = -0.18 to -0.06). Psychomotor speed and working memory, assessed using the TMT, were only impaired in the presence of high microvascular burden. Of the 11 vascular abnormalities considered, white matter hyperintensity, cystatin C-based glomerular filtration rate, large brain infarct, and ankle-arm index were independently associated with cognitive and physical function. Microvascular and macrovascular abnormalities assessed using noninvasive tests of the brain, kidney, and peripheral artery were independently associated with poor cognitive and physical function in older adults. Future research should evaluate the usefulness of these tests in prognostication. © 2015, Copyright the Authors Journal compilation © 2015

  19. A Unique Branching Pattern of the Axillary Artery: A Case Report

    PubMed Central

    Bagoji, Ishwar B.; Hadimani, Gavishiddappa A.; Bannur, Balappa M.; Patil, B.G.; Bharatha, Ambadasu

    2013-01-01

    During routine dissection classes for under graduate students, we found a unique and unusual case regarding the anomalous branching in the third part of the axillary artery was terminated into subscapular arterial trunk, superficial brachial artery and deep brachial artery. The subscapular arterial trunk was origin of several important arteries as the circumflex scapular, thoracodorsal, posterior circumflex humeral, thoraco-acromial and lateral thoracic arteries. The deep brachial artery in the arm gave anterior circumflex humeral artery at the surgical neck of humerus, which terminated in the cubital fossa by dividing into radial and ulnar arteries. The superficial brachial artery gave two profunda brachii arteries, both of which passed through spiral groove, along with radial nerve and three muscular branches, to brachialis muscle. This variation is very rare. As per our knowledge, we did not find any literature which explained variations which were similar to this. The normal and abnormal anatomy of the axillary region has practical importance among vascular radiologists and surgeons and it should be known for making an accurate diagnostic interpretation. PMID:24551680

  20. A unique branching pattern of the axillary artery: a case report.

    PubMed

    Bagoji, Ishwar B; Hadimani, Gavishiddappa A; Bannur, Balappa M; Patil, B G; Bharatha, Ambadasu

    2013-12-01

    During routine dissection classes for under graduate students, we found a unique and unusual case regarding the anomalous branching in the third part of the axillary artery was terminated into subscapular arterial trunk, superficial brachial artery and deep brachial artery. The subscapular arterial trunk was origin of several important arteries as the circumflex scapular, thoracodorsal, posterior circumflex humeral, thoraco-acromial and lateral thoracic arteries. The deep brachial artery in the arm gave anterior circumflex humeral artery at the surgical neck of humerus, which terminated in the cubital fossa by dividing into radial and ulnar arteries. The superficial brachial artery gave two profunda brachii arteries, both of which passed through spiral groove, along with radial nerve and three muscular branches, to brachialis muscle. This variation is very rare. As per our knowledge, we did not find any literature which explained variations which were similar to this. The normal and abnormal anatomy of the axillary region has practical importance among vascular radiologists and surgeons and it should be known for making an accurate diagnostic interpretation.

  1. Long-term follow-up results of umbilical hernia repair

    PubMed Central

    Venclauskas, Linas; Zilinskas, Justas; Zviniene, Kristina; Kiudelis, Mindaugas

    2017-01-01

    Introduction Multiple suture techniques and various mesh repairs are used in open or laparoscopic umbilical hernia (UH) surgery. Aim To compare long-term follow-up results of UH repair in different hernia surgery groups and to identify risk factors for UH recurrence. Material and methods A retrospective analysis of 216 patients who underwent elective surgery for UH during a 10-year period was performed. The patients were divided into three groups according to surgery technique (suture, mesh and laparoscopic repair). Early and long-term follow-up results including hospital stay, postoperative general and wound complications, recurrence rate and postoperative patient complaints were reviewed. Risk factors for recurrence were also analyzed. Results One hundred and forty-six patients were operated on using suture repair, 52 using open mesh and 18 using laparoscopic repair technique. 77.8% of patients underwent long-term follow-up. The postoperative wound complication rate and long-term postoperative complaints were significantly higher in the open mesh repair group. The overall hernia recurrence rate was 13.1%. Only 2 (1.7%) patients with small hernias (< 2 cm) had a recurrence in the suture repair group. Logistic regression analysis showed that body mass index (BMI) > 30 kg/m2, diabetes and wound infection were independent risk factors for umbilical hernia recurrence. Conclusions The overall umbilical hernia recurrence rate was 13.1%. Body mass index > 30 kg/m2, diabetes and wound infection were independent risk factors for UH recurrence. According to our study results, laparoscopic medium and large umbilical hernia repair has slight advantages over open mesh repair concerning early postoperative complications, long-term postoperative pain and recurrence. PMID:29362649

  2. [A case of neurofibromatosis type I associated with basal meningocele and abnormal vessels].

    PubMed

    Yoshioka, H; Sakoda, K; Kohno, H; Hada, H; Hanaya, R; Arita, K; Kurisu, K

    1998-03-01

    A 21-year-old man with neurofibromatosis type 1 (NF 1) had many widespread cutaneous neurofibroma on his right face. Magnetic resonance imaging (MRI) revealed basal meningocele due to dysplasia of the skull base. Carotid and vertebral angiograms revealed occlusion of the right internal carotid artery, persistent primitive trigeminal artery. We have reviewed the clinical and radiographic features of this case of neurofibromatosis, meningocele and cerebral arterial abnormalities. NF associated with both intracranial vascular malformation and meningocele is very rare, and in our case both were thought to arise congenitally as a manifestation of mesodermal dysplasia. Careful follow up using MRI and MR angiography should be performed for such patients.

  3. Flood Syndrome: Spontaneous Umbilical Hernia Rupture Leaking Ascitic Fluid—A Case Report

    PubMed Central

    Nguyen, Emilie T; Tudtud-Hans, Leah A

    2017-01-01

    Introduction We report a rare case of Flood syndrome, which is a spontaneous rupture of an umbilical hernia. Case Presentation A 42-year-old man with decompensated hepatitis C and alcoholic cirrhosis complicated by ascites and esophageal varices presented with 1 day of ascitic fluid drainage after rupture of a preexisting umbilical hernia associated with diffuse abdominal pain and tenderness. A pigtail drain was placed in the right upper abdominal quadrant to decrease fluid drainage from the abdominal wall defect, allowing it to heal naturally. Discussion The spontaneous rupture of an umbilical hernia in our patient highlights a rare complication with high mortality rates and stresses the challenge of treatment that falls in the area between medical and surgical management. PMID:28678688

  4. Umbilical hernia alloplastic dual-mesh treatment in cirrhotic patients.

    PubMed

    Guriță, R E; Popa, F; Bălălău, C; Scăunașu, R V

    2013-03-15

    Abdominal wall hernias represent a pathology with an impressive prevalence among the population of patients with cirrhosis complicated by ascites. The aggressive surgical approach of umbilical hernia for patients with cirrhotic background remains a controversial problem, accompanied by anesthetic and surgical risk. Its indication remains fully justified in case of severe symptoms or life threatening complications: strangulation, incarceration, evisceration. This article evaluates results obtained by using dual-mesh alloplastic materials for surgical treatment of umbilical hernias affecting cirrhotic patients with incipient liver injury. Our lot consists of twelve patients with ages between 45 and 65 years, diagnosed with hepatic cirrhosis, without other associated comorbidities. All patients were admitted for strangulated umbilical hernia. Among the analyzed lot, no decease was encountered, the morbidity being limited to two cases of parietal suppuration, solved conservatively, without the mesh removal. There were no ascitic fistulas. No recurrences were registered for a 12 months tracking period. The presence of cirrhosis implies a high anesthetic and surgical risk, the intervention being grafted by a substantial increase of mortality and morbidity in an emergency setting. The development of new alloplastic materials, together with the modern anesthetic techniques, allows superior results for patients with incipient hepatic injury.

  5. Engraftment of gene-modified umbilical cord blood cells in neonates with adenosine deaminase deficiency

    PubMed Central

    Kohn, Donald B.; Weinberg, Kenneth I.; Nolta, Jan A.; Heiss, Linda N.; Lenarsky, Carl; Crooks, Gay M.; Hanley, Mary E.; Annett, Geralyn; Brooks, Judith S.; El-Khoureiy, Anthony; Lawrence, Kim; Wells, Susie; Moen, Robert C.; Bastian, John; Williams-Herman, Debora E.; Elder, Melissa; Wara, Diane; Bowen, Thomas; Hershfield, Michael S.; Mullen, Craig A.; Blaese, R. Michael; Parkman, Robertson

    2010-01-01

    Haematopoietic stem cells in umbilical cord blood are an attractive target for gene therapy of inborn errors of metabolism. Three neonates with severe combined immunodeficiency were treated by retroviral-mediated transduction of the CD34+ cells from their umbilical cord blood with a normal human adenosine deaminase complementary DNA followed by autologous transplantation. The continued presence and expression of the introduced gene in leukocytes from bone marrow and peripheral blood for 18 months demonstrates that umbilical cord blood cells may be genetically modified with retroviral vectors and engrafted in neonates for gene therapy. PMID:7489356

  6. Detection of chromosomal abnormalities and the 22q11 microdeletion in fetuses with congenital heart defects.

    PubMed

    Lv, Wei; Wang, Shuyu

    2014-11-01

    Chromosomal abnormalities and the 22q11 microdeletion are implicated in congenital heart defects (CHDs). This study was designed to detect these abnormalities in fetuses and determine the effect of genetic factors on CHD etiology. Between January 2010 and December 2011, 113 fetuses with CHD treated at the Beijing Obstetrics and Gynecology Hospital were investigated, using chromosome karyotyping of either amniotic fluid cell or umbilical cord blood cell samples. Fetuses with a normal result were then investigated for the 22q11 microdeletion by fluorescence in situ hybridization. Of the 113 patients, 12 (10.6%) exhibited chromosomal abnormalities, while 6 (5.3%) of the remaining 101 cases presented with a 22q11 microdeletion. The incidence of chromosomal abnormalities was significantly higher in the group of fetuses presenting with extracardiac malformations in addition to CHD (P<0.001), although the detection of the 22q11 microdeletion was not significantly different between the two groups (P=0.583). In addition, all fetuses with the 22q11 microdeletion occurred de novo. In conclusion, genetic factors are important in the etiology of CHD. Where fetuses present with cardiac defects, additional chromosomal analysis is required to detect extracardiac abnormalities. Fetuses with heart defects should also be considered for 22q11 microdeletion detection to evaluate fetal prognosis, particularly prior to surgery.

  7. Intravenous human umbilical cord blood improves electrophysiological and metabolic properties in ISO induced myocardial necrosis in rats.

    PubMed

    Mohan, Mahalaxmi; Rokade, Rahul; Kasturet, Sanjay

    2013-03-01

    Rats treated with isoproterenol (ISO, 85 mg/kg, sc, twice at an interval of 24 h) showed a significant increase in heart rate, mean arterial blood pressure, pressure rate index, ST elevation on ECG, and a significant increase in the levels of cardiac marker enzymes- lactate dehydrogenase, and creatine kinase in serum and a significant reduction in superoxide dismutase, and catalase and increase in thiobarbituric acid reactive substance activity in heart tissue. Treatment with Human umbilical cord blood (hUCBC; 500 and 1000 microL, iv, via the tail vein; 2 h after the second dose of ISO) significantly restored back to normal levels and showed a lesser degree of cellular infiltration and infarct size in histopathological and planimetry studies respectively. Thus, hUCBC ameliorates cardiotoxic effects of isoproterenol and may be of value in the treatment of myocardial infarction.

  8. Systemic treatment of focal brain injury in the rat by human umbilical cord blood cells being at different level of neural commitment.

    PubMed

    Gornicka-Pawlak, El Bieta; Janowski, Miroslaw; Habich, Aleksandra; Jablonska, Anna; Drela, Katarzyna; Kozlowska, Hanna; Lukomska, Barbara; Sypecka, Joanna; Domanska-Janik, Krystyna

    2011-01-01

    The aim of the study was to evaluate therapeutic effectiveness of intra-arterial infusion of human umbilical cord blood (HUCB) derived cells at different stages of their neural conversion. Freshly isolated mononuclear cells (D-0), neurally directed progenitors (D-3) and neural-like stem cells derived from umbilical cord blood (NSC) were compared. Focal brain damage was induced in rats by stereotactic injection of ouabain into dorsolateral striatum Three days later 10(7) of different subsets of HUCB cells were infused into the right internal carotid artery. Following surgery rats were housed in enriched environment for 30 days. Behavioral assessment consisted of tests for sensorimotor deficits (walking beam, rotarod, vibrissae elicited forelimb placing, apomorphine induced rotations), cognitive impairments (habit learning and object recognition) and exploratory behavior (open field). Thirty days after surgery the lesion volume was measured and the presence of donor cells was detected in the brain at mRNA level. At the same time immunohistochemical analysis of brain tissue was performed to estimate the local tissue response of ouabain injured rats and its modulation after HUCB cells systemic treatment. Functional effects of different subsets of cord blood cells shared substantial diversity in various behavioral tests. An additional analysis showed that D-0 HUCB cells were the most effective in functional restoration and reduction of brain lesion volume. None of transplanted cord blood derived cell fractions were detected in rat's brains at 30(th) day after treatment. This may suggest that the mechanism(s) underlying positive effects of HUCB derived cell may concern the other than direct neural cell supplementation. In addition increased immunoreactivity of markers indicating local cells proliferation and migration suggests stimulation of endogenous reparative processes by HUCB D-0 cell interarterial infusion.

  9. Umbilical hernias: the cost of waiting.

    PubMed

    Strosberg, David S; Pittman, Matthew; Mikami, Dean

    2017-02-01

    Umbilical hernias are well described in the literature, but its impact on health care is less understood. The purpose of this study was to investigate the effect of non-operative management of umbilical hernias on cost, work absenteeism, and resource utilization. The Truven Health Database, consisting of 279 employers and over 3000 hospitals, was reviewed for all umbilical hernia patients, aged 18-64 who were enrolled in health plans for 12 months prior to surgery and 12 months after surgery. Patients were excluded if they had a recurrence or had been offered a "no surgery" approach within 1 year of the index date. The remaining patients were separated into surgery (open or laparoscopic repair) or no surgery (NS). Post-cost analysis at 90 and 365 days and estimated days off from work were reviewed for each group. The non-surgery cohort had a higher proportion of females and comorbidity index. Adjusted analysis showed significantly higher 90 and 365 costs for the surgery group (p < 0.0001), though the cost difference did decrease over time. NS group had significantly higher estimated days of health-care utilization at both the 90 (1.99 vs. 3.58 p < 0.0001) and 365 (8.69 vs. 11.04 p < 0.0001) day post-index mark. A subgroup analysis demonstrated laparoscopic repair had higher costs compared to open primarily due to higher index procedure costs (p < 0.05). Though the financial costs were found to be higher in the surgery group, the majority of these were due to the surgery itself. Significantly higher days of health-care utilization and estimated days off work were experienced in the NS group. It is our belief that early operative intervention will lead to decreased costs and resource utilization.

  10. Agreement of arterial sodium and arterial potassium levels with venous sodium and venous potassium in patients admitted to intensive care unit.

    PubMed

    Nanda, Sunil Kumar; Ray, Lopamudra; Dinakaran, Asha

    2015-02-01

    Electrolyte abnormalities are one of the common causes of morbidity and mortality in critically ill patients. The turnaround time for electrolyte reporting should be as low as possible. Electrolytes are measured conventionally in serum obtained from venous blood by electrolyte analyser which takes 20 to 30 min. Point of care analysers are now available where in electrolytes can be measured in arterial blood within 5 min. This study was done to study the agreement of arterial sodium and arterial potassium with venous sodium and venous potassium levels. Venous sodium and venous potassium levels and arterial sodium and arterial potassium levels were analysed on 206 patient samples admitted to Intensive Care Unit (ICU). The venous values were compared with the arterial values for correlation. Venous sodium was compared with arterial sodium by spearman correlation. Venous potassium was compared with arterial potassium by pearson correlation. The mean value of arterial sodium was 134 and venous sodium was 137. The mean value of arterial potassium was 3.6 and venous potassium was 4.1. The correlation coefficient obtained for sodium was 0.787 and correlation coefficient obtained for potassium was 0.701. There was positive correlation of arterial sodium and arterial potassium with venous sodium and venous potassium indicating agreement between the parameters. Arterial sodium and arterial potassium can be used instead of venous sodium and venous potassium levels in management of critically ill patients.

  11. Increased response of diastolic blood pressure to exercise in patients with coronary artery disease: an index of latent ventricular dysfunction?

    PubMed Central

    Paraskevaidis, I A; Kremastinos, D T; Kassimatis, A S; Karavolias, G K; Kordosis, G D; Kyriakides, Z S; Toutouzas, P K

    1993-01-01

    OBJECTIVE--To determine whether an abnormal response of diastolic blood pressure during treadmill exercise stress testing correlated with the number of obstructed vessels and with left ventricular systolic function in patients with coronary artery disease. DESIGN--Diastolic blood pressure was measured invasively during exercise stress testing and coronary angiograms and left ventriculograms were obtained at rest in patients with coronary artery disease. The abnormal (> or = 15 mm Hg) diastolic blood pressure response was compared with the number of obstructed coronary arteries and with left ventricular systolic function. SETTING--Two tertiary referral centres. PATIENTS--50 consecutive patients (mean age 57 years) with coronary artery disease. MAIN OUTCOME MEASURES--The increase in diastolic blood pressure during exercise and its correlation with the appearance and disappearance of ST segment deviation, resting left ventricular systolic function, and the number of obstructed coronary arteries. RESULTS--Group 1: 10 (20%) patients (three with one, four with two, and three with three vessel coronary artery disease) (mean (SD) age 54.7 (12) years) had an abnormal diastolic blood pressure response that appeared 1.2 (0.3) min before ST segment deviation and became normal 0.9 (0.3) min after the ST segment returned to normal. Group 2: 40 (80%) patients (12 with one, 16 with two, and 12 with three vessel coronary arteries disease) (aged 56.8 (8.2) years) had a normal diastolic blood pressure response to stress testing. The ejection fraction (46.3 (5)%) and cardiac index (2.6 (0.1) 1/min/m2) in group 1 were less than in group 2 (61.6 (4.2)% and 3.8 (0.3) 1/min/m2 respectively, p < or = 0.001). The end systolic volume was greater in group 1 than in group 2: 38.7 (0.7 ml/m2 v 28.2 (2.1) ml/m2, p < or = 0.001. CONCLUSION--In patients with coronary artery disease an abnormal increase in diastolic blood pressure during exercise stress testing correlated well with left ventricular

  12. Modeling the circle of Willis to assess the effect of anatomical variations on the development of unilateral internal carotid artery stenosis.

    PubMed

    Zhang, Chi; Wang, Ling; Li, Xiaoyun; Li, Shuyu; Pu, Fang; Fan, Yubo; Li, Deyu

    2014-01-01

    Circle of Willis (CoW) plays a significant role in maintaining the blood supply for the brain. Specifically, when the stenosis occurs in the internal carotid artery (ICA), abnormal structures of CoW would decrease the compensatory capacity, leading to the local insufficiency of cerebral blood supply. The present paper built a series of lumped parameter models for CoW, and simulated the blood redistribution caused by the unilateral ICA stenosis with different severities in cerebral arteries in the normal and abnormal CoW respectively. The results showed that when unilateral ICA stenosis occurred, the collateral circulation was built through the anterior communicating artery and the ipsilateral posterior communicating artery, maintaining the flow in cerebral arteries. The absence of the two communicating arteries would cause an obvious decrease of flow in local cerebral arteries in the anterior circulation. In conclusion, the two arteries play a significant role in maintaining the balance of cerebral blood supply in the development of ICA stenosis.

  13. Orion Service Module Umbilical (OSMU) Testing Complete

    NASA Image and Video Library

    2016-10-19

    Testing of the Orion Service Module Umbilical (OSMU) was completed at the Launch Equipment Test Facility at NASA’s Kennedy Space Center in Florida. The OSMU was attached to Vehicle Motion Simulator 1 for a series of simulated launch tests to validate it for installation on the mobile launcher. The mobile launcher tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. Kennedy's Engineering Directorate is providing support to the Ground Systems Development and Operations Program for testing of the OSMU. EM-1 is scheduled to launch in 2018.

  14. Microbial load of umbilical cord blood Ureaplasma species and Mycoplasma hominis in preterm prelabor rupture of membranes.

    PubMed

    Kacerovsky, Marian; Pliskova, Lenka; Menon, Ramkumar; Kutova, Radka; Musilova, Ivana; Maly, Jan; Andrys, Ctirad

    2014-11-01

    To evaluate Ureaplasma species and M. hominis DNA in the umbilical cord blood and its correlation with its microbial load in the amniotic fluid, as a measure of microbial burden in fetal inflammatory response and neonatal outcome in pregnancies complicated by preterm prelabor rupture of membranes (pPROM). A retrospective study of 158 women with singleton pregnancies complicated by pPROM between 24(0/7) and 36(6/7) weeks was conducted. Amniotic fluid was obtained from all women by transabdominal amniocentesis, and umbilical cord blood was obtained by venipuncture from umbilical cords immediately after the delivery of the neonates. The Ureaplasma species and M. hominis DNA was quantitated using absolute quantification techniques. Ureaplasma species and M. hominis DNA was identified in 9% of the umbilical cord blood samples. No correlation between the amniotic fluid and umbilical cord blood microbial load was observed. The presence of Ureaplasma species and M. hominis DNA in the umbilical cord blood had no impact on short-term neonatal morbidity. A high microbial load of genital mycoplasma Ureaplasma species DNA in the umbilical cord in pregnancies complicated by pPROM is not associated with a high fetal inflammatory response and is therefore not associated with serious neonatal morbidity.

  15. Coronary artery anomalies in Turner Syndrome.

    PubMed

    Viuff, Mette H; Trolle, Christian; Wen, Jan; Jensen, Jesper M; Nørgaard, Bjarne L; Gutmark, Ephraim J; Gutmark-Little, Iris; Mortensen, Kristian H; Gravholt, Claus Højbjerg; Andersen, Niels H

    Congenital heart disease, primarily involving the left-sided structures, is often seen in patients with Turner Syndrome. Moreover, a few case reports have indicated that coronary anomalies may be more prevalent in Turner Syndrome than in the normal population. We therefore set out to systematically investigate coronary arterial anatomy by computed tomographic coronary angiography (coronary CTA) in Turner Syndrome patients. Fifty consecutive women with Turner Syndrome (mean age 47 years [17-71]) underwent coronary CTA. Patients were compared with 25 gender-matched controls. Coronary anomaly was more frequent in patients with Turner Syndrome than in healthy controls [20% vs. 4% (p = 0.043)]. Nine out of ten abnormal cases had an anomalous left coronary artery anatomy (absent left main trunk, n = 7; circumflex artery originating from the right aortic sinus, n = 2). One case had a tubular origin of the right coronary artery above the aortic sinus. There was no correlation between the presence of coronary arterial anomalies and karyotype, bicuspid aortic valve, or other congenital heart defects. Coronary anomalies are highly prevalent in Turner Syndrome. The left coronary artery is predominantly affected, with an absent left main coronary artery being the most common anomaly. No hemodynamically relevant coronary anomalies were found. Copyright © 2016 Society of Cardiovascular Computed Tomography. All rights reserved.

  16. Patent ductus arteriosus associated with congenital anomaly of coronary artery.

    PubMed

    Maleki, Majid; Azizian, Nassrin; Esmaeilzadeh, Maryam; Moradi, Bahieh

    2013-11-01

    We reported a case of patent ductus arteriosus (PDA) with congenital anomaly of coronary arteries as abnormal origin of right coronary artery (RCA) and left coronary artery (LCA) from a single ostium of the right coronary sinus. A 21-year-old man referred to our institution for evaluation of cardiac murmur. He has suffered from palpitation and atypical chest pain for three months. On physical examination, a continuous murmur was heard in the second left parasternal space. Transthoracic echocardiography showed normal left and right ventricular size and systolic function (LVEF = 55%). Main pulmonary artery (PA) and left pulmonary artery (LPA) branch were considerably dilated. Considering normal coronary flow, lack of clinical evidence of myocardial ischemia and echocardiography findings, patient underwent surgical closure of PDA via left thoracotomy and after five days discharged uneventfully.

  17. Detection of in utero cannabis exposure by umbilical cord analysis.

    PubMed

    Kim, Jiyoung; de Castro, Ana; Lendoiro, Elena; Cruz-Landeira, Angelines; López-Rivadulla, Manuel; Concheiro, Marta

    2018-04-01

    According to the 2014 National Survey on Drug Use and Health, 5.3% of pregnant women smoked marijuana in the past month. This prevalence is expected to increase as a growing number of states and countries are now considering legalization. Although the umbilical cord is becoming a useful objective tool to detect in utero drug exposure, currently data about analytical methods and its utility to detect cannabis exposure are scarce. The objective of this work was to develop a method for the determination of Δ 9 -tetrahydrocannabinol (THC), 11-hydroxyTHC (THC-OH), 11-nor-9-carboxy-THC (THCCOOH), 8-β-11-dihydroxyTHC (THC-diOH), THC and THCCOOH glucuronides, and cannabidiol (CBD) in the umbilical cord by liquid chromatography-tandem mass spectrometry (LC-MS/MS) with dual ionization source. Umbilical cord samples (0.5 g) were homogenized in methanol and extracted by solid-phase extraction. Reversed-phase chromatographic separation was performed in 14 minutes, and 2 transitions per analyte were monitored in multiple reaction monitoring mode. Method validation included linearity (1-10 to 20-200 ng/g), precision (4.1%-23.4%), accuracy (87.5%-111.4%), matrix effect (-54.8% to -5.8%), extraction efficiency (25%-45.6%), limits of detection and quantification (1-10 ng/g), and endogenous (n = 5) or exogenous interferences (not detected). The method was applied to 13 authentic samples from cannabis-exposed newborns, which meconium samples had tested positive for cannabis. Twelve cord specimens tested positive for THCCOOH-glucuronide (1.6-19.1 ng/g). We developed and validated a specific and sensitive method for the simultaneous determination of THC, its metabolites, including THC and THCCOOH glucuronides, and CBD in umbilical cord samples by LC-MS/MS. The analysis of authentic samples showed the usefulness of umbilical cord to detect cannabis in utero exposure. Copyright © 2017 John Wiley & Sons, Ltd.

  18. Associations between intrapartum death and piglet, placental, and umbilical characteristics.

    PubMed

    Rootwelt, V; Reksen, O; Farstad, W; Framstad, T

    2012-12-01

    Intrapartum death in multiparous gestations in sows (Sus scrofa) is often caused by hypoxia. There is little information in the literature on the assessment of the placenta in relation to intrapartum death in piglets. The aim of this study was to evaluate the impact of the placental area and weight upon piglet birth characteristics and intrapartum death. Litters from 26 Landrace-Yorkshire sows were monitored during farrowing and the status of each piglet was recorded, including blood parameters of piglets and their umbilical veins. Of 413 piglets born, 6.5% were stillborn. Blood concentrations of glucose, lactate, and CO(2) partial pressure were increased in the stillborn piglets (P < 0.05) and corresponding umbilical veins (P < 0.01) vs. live-born piglets, whereas pH and base excess were decreased (P < 0.001). Time from onset of parturition until birth was increased for piglets born dead vs. live (P < 0.001). Mean birth weight for piglets born dead was not different from live-born piglets (P = 0.631), whereas mean body mass index was reduced (P < 0.001). Mean placental area and placental weight belonging to stillborn piglets were not different from live-born piglets (P = 0.662 and P = 0.253, respectively). Blood concentrations of lactate, hemoglobin, and hematocrit recorded in all piglets pooled were associated with placental area (P < 0.05), but not with placental weight (P > 0.2). Piglet BW was positively correlated with placental area and placental weight (P < 0.001). The risk of being born dead increased with increasing birth order group, and broken umbilical cords explained 71% of the stillbirths (P = 0.001). We conclude that placental area and placental weight are both positively associated with piglet birth weight, but not with the probability of being born dead. Placental area was a better predictor of piglet vitality than placental weight. Because umbilical cord rupture and prolonged birth time were associated with being born dead, umbilical cord rupture

  19. Concentrations of pentosidine, an advanced glycation end-product, in umbilical cord blood.

    PubMed

    Tsukahara, Hirokazu; Ohta, Naoko; Sato, Shuko; Hiraoka, Masahiro; Shukunami, Ken-Ichi; Uchiyama, Mayumi; Kawakami, Hisako; Sekine, Kyouichi; Mayumi, Mitsufumi

    2004-07-01

    Advanced glycation end-products (AGEs) are formed over several weeks to months by non-enzymatic glycation and oxidation ("glycoxidation") reactions between carbohydrate-derived carbonyl groups and protein amino groups, known as the Maillard reaction. Pentosidine is one of the best-characterized AGEs and is accepted as a satisfactory marker for glycoxidation in vivo. The present study was intended to measure pentosidine concentrations in umbilical cord blood from newborns with various gestational ages using our recently established high-performance liquid chromatography method [Tsukahara, H. et al. (2003) Pediatr. Res. 54, 419-424]. Our study demonstrates, for the first time, that pentosidine is detected in most of the umbilical blood samples. This study also shows that the umbilical blood concentrations of pentosidine are considerably lower than normal adult values, but that they increase with gestation progression and fetal growth. Umbilical pentosidine concentrations were significantly elevated in newborns of mothers with preeclampsia compared to those of mothers without preeclampsia. We conclude that accumulation of AGEs and oxidative stress occurs in fetal tissues and organs in utero at the early stage of human life and that their accumulation is augmented in the maternal preeclampsic condition.

  20. Oxidative and inflammatory signals in obesity-associated vascular abnormalities.

    PubMed

    Reho, John J; Rahmouni, Kamal

    2017-07-15

    Obesity is associated with increased cardiovascular morbidity and mortality in part due to vascular abnormalities such as endothelial dysfunction and arterial stiffening. The hypertension and other health complications that arise from these vascular defects increase the risk of heart diseases and stroke. Prooxidant and proinflammatory signaling pathways as well as adipocyte-derived factors have emerged as critical mediators of obesity-associated vascular abnormalities. Designing treatments aimed specifically at improving the vascular dysfunction caused by obesity may provide an effective therapeutic approach to prevent the cardiovascular sequelae associated with excessive adiposity. In this review, we discuss the recent evidence supporting the role of oxidative stress and cytokines and inflammatory signals within the vasculature as well as the impact of the surrounding perivascular adipose tissue (PVAT) on the regulation of vascular function and arterial stiffening in obesity. In particular, we focus on the highly plastic nature of the vasculature in response to altered oxidant and inflammatory signaling and highlight how weight management can be an effective therapeutic approach to reduce the oxidative stress and inflammatory signaling and improve vascular function. © 2017 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.

  1. Adherent umbilical hernia containing Meckel's diverticulum resected due to intraoperative injury.

    PubMed

    Kibil, Wojciech; Pach, Radosław; Szura, Mirosław; Matyja, Andrzej

    2012-01-01

    The aim of this report was to describe a rare case of a male patient with dry umbilical hernia with Meckel's diverticulum adherent to the neck of hernia sac. The patient's history, results of physical examination, laboratory testing, intraoperative findings, treatment method and postoperative course are summarized in details in this report. Follow-up visits were performed 14 days, one month and one year after the operation. A 35-year-old overweight Caucasian male patient (initials: D-B, body weight 90 kg, height 172 cm) was admitted to the hospital on 2nd April 2009 with reducible umbilical hernia for elective surgical treatment. The patient was operated on in the Specialist Diagnostic and Therapeutic Centre Medicina in Cracow and discharged from the hospital on fourth postoperative day. This case is compared with a few similar cases which have been described in the literature till now--all of these reports dealt with strangulated umbilical hernias but not reducible one. The patient underwent elective operation performed on the day of admission. Antibiotic prophylaxis included single dose of pefloxacine (400 mg intravenously) administered just before start of the operation. Subarachnoid anaesthesia was applied 15 minutes before start of the operation. The procedure lasted 75 minutes. Hernia sac was dissected and opened. In the hernia neck adherent Meckel's diverticulum was found. It was localised 80 cm from ileocecal valve and its length was 45 millimetres. During dissection process the diverticulum was injured in the apical region so cuneiform resection of the ileum with Meckel's diverticulum was performed. Ileum was sutured with two layers of absorbable sutures. The tissue defect in umbilical region was repaired primarily with onlay synthetic mesh prosthesis (polypropylene mesh, size 7 x 12 cm). 1) Adherent incidental Meckel's diverticulum in a sac of reducible umbilical hernia is a very rare finding. 2) During umbilical herniorrhaphy (elective or urgent) the

  2. Electrocardiogram abnormalities and coronary calcification in postmenopausal women.

    PubMed

    Sabour, Siamak; Grobbee, Diederick; Rutten, Annemarieke; Prokop, Mathias; Bartelink, Marie-Louise; van der Schouw, Yvonne; Bots, Michiel

    2010-01-01

    An electrocardiogram (ECG) can provide information on subclinical myocardial damage. The presence, and more importantly, the quantity of coronary artery calcification (CAC), relates well with the overall severity of the atherosclerotic process. A strong relation has been demonstrated between coronary calcium burden and the incidence of myocardial infarction, a relation independent of age. The aim of this study was to assess the relation of left ventricular hypertrophy (LVH) and ECG abnormalities with CAC. The study population comprised 566 postmenopausal women selected from a population-based cohort study. Information on LVH and repolarization abnormalities (T-axis and QRS-T angle) was obtained using electrocardiography. Modular ECG Analysis System (MEANS) was used to assess ECG abnormalities. The women underwent a multi detector-row computed tomography (MDCT) scan (Philips Mx 8000 IDT 16) to assess CAC. The Agatston score was used to quantify CAC; scores greater than zero were considered as the presence of coronary calcium. Logistic regression was used to assess the relation of ECG abnormality with coronary calcification. LVH was found in 2.7% (n = 15) of the women. The prevalence of T-axis abnormality was 6% (n = 34), whereas 8.5% (n = 48) had a QRS-T angle abnormality. CAC was found in 62% of the women. Compared to women with a normal T-axis, women with borderline or abnormal T-axes were 3.8 fold more likely to have CAC (95% CI: 1.4-10.2). Similarly, compared to women with a normal QRS-T angle, in women with borderline or abnormal QRS-T angle, CAC was 2.0 fold more likely to be present (95% CI: 1.0-4.1). Among women with ECG abnormalities reflecting subclinical ischemia, CAC is commonly found and may in part explain the increased coronary heart disease risk associated with these ECG abnormalities.

  3. Electrocardiogram Abnormalities and Coronary Calcification in Postmenopausal Women

    PubMed Central

    Sabour, Siamak; Grobbee, Diederick; Rutten, Annemarieke; Prokop, Mathias; Bartelink, Marie-Louise; van der Schouw, Yvonne; Bots, Michiel

    2010-01-01

    Background: An electrocardiogram (ECG) can provide information on subclinical myocardial damage. The presence, and more importantly, the quantity of coronary artery calcification (CAC), relates well with the overall severity of the atherosclerotic process. A strong relation has been demonstrated between coronary calcium burden and the incidence of myocardial infarction, a relation independent of age. The aim of this study was to assess the relation of left ventricular hypertrophy (LVH) and ECG abnormalities with CAC. Methods: The study population comprised 566 postmenopausal women selected from a population-based cohort study. Information on LVH and repolarization abnormalities (T-axis and QRS-T angle) was obtained using electrocardiography. Modular ECG Analysis System (MEANS) was used to assess ECG abnormalities. The women underwent a multi detector-row computed tomography (MDCT) scan (Philips Mx 8000 IDT 16) to assess CAC. The Agatston score was used to quantify CAC; scores greater than zero were considered as the presence of coronary calcium. Logistic regression was used to assess the relation of ECG abnormality with coronary calcification. Results: LVH was found in 2.7% (n = 15) of the women. The prevalence of T-axis abnormality was 6% (n = 34), whereas 8.5% (n = 48) had a QRS-T angle abnormality. CAC was found in 62% of the women. Compared to women with a normal T-axis, women with borderline or abnormal T-axes were 3.8 fold more likely to have CAC (95% CI: 1.4–10.2). Similarly, compared to women with a normal QRS-T angle, in women with borderline or abnormal QRS-T angle, CAC was 2.0 fold more likely to be present (95% CI: 1.0–4.1). Conclusion: Among women with ECG abnormalities reflecting subclinical ischemia, CAC is commonly found and may in part explain the increased coronary heart disease risk associated with these ECG abnormalities. PMID:23074563

  4. Spatiotemporal image correlation-derived volumetric Doppler impedance indices from spherical samples of the placenta: intraobserver reliability and correlation with conventional umbilical artery Doppler indices.

    PubMed

    Welsh, A W; Hou, M; Meriki, N; Martins, W P

    2012-10-01

    Volumetric impedance indices derived from spatiotemporal image correlation (STIC) power Doppler ultrasound (PDU) might overcome the influence of machine settings and attenuation. We examined the feasibility of obtaining these indices from spherical samples of anterior placentas in healthy pregnancies, and assessed intraobserver reliability and correlation with conventional umbilical artery (UA) impedance indices. Uncomplicated singleton pregnancies with anterior placenta were included in the study. A single observer evaluated UA pulsatility index (PI), resistance index (RI) and systolic/diastolic ratio (S/D) and acquired three STIC-PDU datasets from the placenta just above the placental cord insertion. Another observer analyzed the STIC-PDU datasets using Virtual Organ Computer-aided AnaLysis (VOCAL) spherical samples from every frame to determine the vascularization index (VI) and vascularization flow index (VFI); maximum, minimum and average values were used to determine the three volumetric impedance indices (vPI, vRI, vS/D). Intraobserver reliability was examined by intraclass correlation coefficients (ICC) and association between volumetric indices from placenta, and UA Doppler indices were assessed by Pearson's correlation coefficient. A total of 25 pregnant women were evaluated but five were excluded because of artifacts observed during analysis. The reliability of measurement of volumetric indices of both VI and VFI from three STIC-PDU datasets was similar, with all ICCs ≥ 0.78. Pearson's r values showed a weak and non-significant correlation between UA pulsed-wave Doppler indices and their respective volumetric indices from spherical samples of placenta (all r ≥ 0.23). VOCAL indices from specific phases of the cardiac cycle showed good repeatability (ICC ≥ 0.92). Volumetric impedance indices determined from spherical samples of placenta are sufficiently reliable but do not correlate with UA Doppler indices in healthy pregnancies. Copyright © 2012

  5. Pregnancy Complications: Umbilical Cord Abnormalities

    MedlinePlus

    ... before and during delivery, which may contribute to cerebral palsy and other forms of brain damage References Cruikshank, ... before and during delivery, which may contribute to cerebral palsy and other forms of brain damage References Cruikshank, ...

  6. N‐Acetylcysteine, a glutathione precursor, reverts vascular dysfunction and endothelial epigenetic programming in intrauterine growth restricted guinea pigs

    PubMed Central

    Herrera, Emilio A.; Cifuentes‐Zúñiga, Francisca; Figueroa, Esteban; Villanueva, Cristian; Hernández, Cherie; Alegría, René; Arroyo‐Jousse, Viviana; Peñaloza, Estefania; Farías, Marcelo; Uauy, Ricardo; Casanello, Paola

    2016-01-01

    Key points Intrauterine growth restriction (IUGR) is associated with vascular dysfunction, oxidative stress and signs of endothelial epigenetic programming of the umbilical vessels.There is no evidence that this epigenetic programming is occurring on systemic fetal arteries.In IUGR guinea pigs we studied the functional and epigenetic programming of endothelial nitric oxide synthase (eNOS) (Nos3 gene) in umbilical and systemic fetal arteries, addressing the role of oxidative stress in this process by maternal treatment with N‐acetylcysteine (NAC) during the second half of gestation.The present study suggests that IUGR endothelial cells have common molecular markers of programming in umbilical and systemic arteries. Notably, maternal treatment with NAC restores fetal growth by increasing placental efficiency and reverting the functional and epigenetic programming of eNOS in arterial endothelium in IUGR guinea pigs. Abstract In humans, intrauterine growth restriction (IUGR) is associated with vascular dysfunction, oxidative stress and signs of endothelial programming in umbilical vessels. We aimed to determine the effects of maternal antioxidant treatment with N‐acetylcysteine (NAC) on fetal endothelial function and endothelial nitric oxide synthase (eNOS) programming in IUGR guinea pigs. IUGR was induced by implanting ameroid constrictors on uterine arteries of pregnant guinea pigs at mid gestation, half of the sows receiving NAC in the drinking water (from day 34 until term). Fetal biometry and placental vascular resistance were followed by ultrasound throughout gestation. At term, umbilical arteries and fetal aortae were isolated to assess endothelial function by wire‐myography. Primary cultures of endothelial cells (ECs) from fetal aorta, femoral and umbilical arteries were used to determine eNOS mRNA levels by quantitative PCR and analyse DNA methylation in the Nos3 promoter by pyrosequencing. Doppler ultrasound measurements showed that NAC reduced

  7. N-Acetylcysteine, a glutathione precursor, reverts vascular dysfunction and endothelial epigenetic programming in intrauterine growth restricted guinea pigs.

    PubMed

    Herrera, Emilio A; Cifuentes-Zúñiga, Francisca; Figueroa, Esteban; Villanueva, Cristian; Hernández, Cherie; Alegría, René; Arroyo-Jousse, Viviana; Peñaloza, Estefania; Farías, Marcelo; Uauy, Ricardo; Casanello, Paola; Krause, Bernardo J

    2017-02-15

    Intrauterine growth restriction (IUGR) is associated with vascular dysfunction, oxidative stress and signs of endothelial epigenetic programming of the umbilical vessels. There is no evidence that this epigenetic programming is occurring on systemic fetal arteries. In IUGR guinea pigs we studied the functional and epigenetic programming of endothelial nitric oxide synthase (eNOS) (Nos3 gene) in umbilical and systemic fetal arteries, addressing the role of oxidative stress in this process by maternal treatment with N-acetylcysteine (NAC) during the second half of gestation. The present study suggests that IUGR endothelial cells have common molecular markers of programming in umbilical and systemic arteries. Notably, maternal treatment with NAC restores fetal growth by increasing placental efficiency and reverting the functional and epigenetic programming of eNOS in arterial endothelium in IUGR guinea pigs. In humans, intrauterine growth restriction (IUGR) is associated with vascular dysfunction, oxidative stress and signs of endothelial programming in umbilical vessels. We aimed to determine the effects of maternal antioxidant treatment with N-acetylcysteine (NAC) on fetal endothelial function and endothelial nitric oxide synthase (eNOS) programming in IUGR guinea pigs. IUGR was induced by implanting ameroid constrictors on uterine arteries of pregnant guinea pigs at mid gestation, half of the sows receiving NAC in the drinking water (from day 34 until term). Fetal biometry and placental vascular resistance were followed by ultrasound throughout gestation. At term, umbilical arteries and fetal aortae were isolated to assess endothelial function by wire-myography. Primary cultures of endothelial cells (ECs) from fetal aorta, femoral and umbilical arteries were used to determine eNOS mRNA levels by quantitative PCR and analyse DNA methylation in the Nos3 promoter by pyrosequencing. Doppler ultrasound measurements showed that NAC reduced placental vascular resistance

  8. Lysyl Oxidase Induces Vascular Oxidative Stress and Contributes to Arterial Stiffness and Abnormal Elastin Structure in Hypertension: Role of p38MAPK.

    PubMed

    Martínez-Revelles, Sonia; García-Redondo, Ana B; Avendaño, María S; Varona, Saray; Palao, Teresa; Orriols, Mar; Roque, Fernanda R; Fortuño, Ana; Touyz, Rhian M; Martínez-González, Jose; Salaices, Mercedes; Rodríguez, Cristina; Briones, Ana M

    2017-09-01

    Vascular stiffness, structural elastin abnormalities, and increased oxidative stress are hallmarks of hypertension. Lysyl oxidase (LOX) is an elastin crosslinking enzyme that produces H 2 O 2 as a by-product. We addressed the interplay between LOX, oxidative stress, vessel stiffness, and elastin. Angiotensin II (Ang II)-infused hypertensive mice and spontaneously hypertensive rats (SHR) showed increased vascular LOX expression and stiffness and an abnormal elastin structure. Mice over-expressing LOX in vascular smooth muscle cells (TgLOX) exhibited similar mechanical and elastin alterations to those of hypertensive models. LOX inhibition with β-aminopropionitrile (BAPN) attenuated mechanical and elastin alterations in TgLOX mice, Ang II-infused mice, and SHR. Arteries from TgLOX mice, Ang II-infused mice, and/or SHR exhibited increased vascular H 2 O 2 and O 2 .- levels, NADPH oxidase activity, and/or mitochondrial dysfunction. BAPN prevented the higher oxidative stress in hypertensive models. Treatment of TgLOX and Ang II-infused mice and SHR with the mitochondrial-targeted superoxide dismutase mimetic mito-TEMPO, the antioxidant apocynin, or the H 2 O 2 scavenger polyethylene glycol-conjugated catalase (PEG-catalase) reduced oxidative stress, vascular stiffness, and elastin alterations. Vascular p38 mitogen-activated protein kinase (p38MAPK) activation was increased in Ang II-infused and TgLOX mice and this effect was prevented by BAPN, mito-TEMPO, or PEG-catalase. SB203580, the p38MAPK inhibitor, normalized vessel stiffness and elastin structure in TgLOX mice. We identify LOX as a novel source of vascular reactive oxygen species and a new pathway involved in vascular stiffness and elastin remodeling in hypertension. LOX up-regulation is associated with enhanced oxidative stress that promotes p38MAPK activation, elastin structural alterations, and vascular stiffness. This pathway contributes to vascular abnormalities in hypertension. Antioxid. Redox Signal. 27

  9. Efficacy of intra-umbilical oxytocin in the management of retained placenta: a randomized controlled trial.

    PubMed

    Samanta, Ajanta; Roy, Samir Ghosh; Mistri, Pallab Kumar; Mitra, Anirban; Pal, Ranjan; Naskar, Animesh; Bhattacharya, Sanjay Kumar; Pal, Partha Pratim; Pande, Arindam

    2013-01-01

    Retained placenta is an important cause of maternal mortality. The present study was aimed to determine the efficacy of umbilical injection of oxytocin as a treatment modality in this condition. This was a single-center randomized controlled trial incorporating 58 women with retained placenta of more than 30 min, equally distributed into two study arms of intra-umbilical injection of oxytocin (50 IU oxytocin diluted with normal saline [NS] to a total volume 30 mL) and intra-umbilical injection of NS (30 mL). Primary outcome was expulsion of the placenta within 30 min following intervention. All the data were analyzed on an intention-to-treat basis. The success rate in the intra-umbilical oxytocin group was 51.72% compared to 20.69% in the control arm. This difference in the primary outcome was statistically significant with a P-value<0.05 (P=0.014) favoring intra-umbilical oxytocin infusion with an efficacy rate of 1.5 and a number-needed-to-treat of 3. The peripartum bleeding complications were more in the NS group with a statistically higher (P<0.001) requirement of extra oxytocin to control post-partum bleeding. There were no differences between the two groups in respect to other secondary outcomes, such as post-partum fever, antibiotic requirement and hospital stay.   Umbilical vein injection of 50IU oxytocin in 30mL of NS delivered effectively via the umbilical cord with milking in cases of retained placenta seems a simple and promising technique to reduce the incidence of a potentially morbid procedure and other complications. © 2012 The Authors. Journal of Obstetrics and Gynaecology Research © 2012 Japan Society of Obstetrics and Gynecology.

  10. Musculoskeletal tissue engineering with human umbilical cord mesenchymal stromal cells

    PubMed Central

    Wang, Limin; Ott, Lindsey; Seshareddy, Kiran; Weiss, Mark L; Detamore, Michael S

    2011-01-01

    Multipotent mesenchymal stromal cells (MSCs) hold tremendous promise for tissue engineering and regenerative medicine, yet with so many sources of MSCs, what are the primary criteria for selecting leading candidates? Ideally, the cells will be multipotent, inexpensive, lack donor site morbidity, donor materials should be readily available in large numbers, immunocompatible, politically benign and expandable in vitro for several passages. Bone marrow MSCs do not meet all of these criteria and neither do embryonic stem cells. However, a promising new cell source is emerging in tissue engineering that appears to meet these criteria: MSCs derived from Wharton’s jelly of umbilical cord MSCs. Exposed to appropriate conditions, umbilical cord MSCs can differentiate in vitro along several cell lineages such as the chondrocyte, osteoblast, adipocyte, myocyte, neuronal, pancreatic or hepatocyte lineages. In animal models, umbilical cord MSCs have demonstrated in vivo differentiation ability and promising immunocompatibility with host organs/tissues, even in xenotransplantation. In this article, we address their cellular characteristics, multipotent differentiation ability and potential for tissue engineering with an emphasis on musculoskeletal tissue engineering. PMID:21175290

  11. Evaluation of three high abundance protein depletion kits for umbilical cord serum proteomics

    PubMed Central

    2011-01-01

    Background High abundance protein depletion is a major challenge in the study of serum/plasma proteomics. Prior to this study, most commercially available kits for depletion of highly abundant proteins had only been tested and evaluated in adult serum/plasma, while the depletion efficiency on umbilical cord serum/plasma had not been clarified. Structural differences between some adult and fetal proteins (such as albumin) make it likely that depletion approaches for adult and umbilical cord serum/plasma will be variable. Therefore, the primary purposes of the present study are to investigate the efficiencies of several commonly-used commercial kits during high abundance protein depletion from umbilical cord serum and to determine which kit yields the most effective and reproducible results for further proteomics research on umbilical cord serum. Results The immunoaffinity based kits (PROTIA-Sigma and 5185-Agilent) displayed higher depletion efficiency than the immobilized dye based kit (PROTBA-Sigma) in umbilical cord serum samples. Both the PROTIA-Sigma and 5185-Agilent kit maintained high depletion efficiency when used three consecutive times. Depletion by the PROTIA-Sigma Kit improved 2DE gel quality by reducing smeared bands produced by the presence of high abundance proteins and increasing the intensity of other protein spots. During image analysis using the identical detection parameters, 411 ± 18 spots were detected in crude serum gels, while 757 ± 43 spots were detected in depleted serum gels. Eight spots unique to depleted serum gels were identified by MALDI- TOF/TOF MS, seven of which were low abundance proteins. Conclusions The immunoaffinity based kits exceeded the immobilized dye based kit in high abundance protein depletion of umbilical cord serum samples and dramatically improved 2DE gel quality for detection of trace biomarkers. PMID:21554704

  12. The risk of umbilical hernia and other complications with laparoendoscopic single-site surgery.

    PubMed

    Gunderson, Camille C; Knight, Jason; Ybanez-Morano, Jessica; Ritter, Carol; Escobar, Pedro F; Ibeanu, Okechukwu; Grumbine, Francis C; Bedaiwy, Mohamed A; Hurd, William W; Fader, Amanda Nickles

    2012-01-01

    To estimate the risk of umbilical hernia and other latent complications in women who underwent laparoendoscopic single-site surgery (LESS) for a gynecologic indication. Retrospective, nonrandomized clinical study (Canadian Task Force classification II-2). Four tertiary care academic medical centers. Women undergoing LESS for a benign or malignant gynecologic indication from 2009 to 2011. A total of 211 women underwent LESS via a single 1.5- to 2.0-cm umbilical incision. All surgeries were performed by advanced gynecologic laparoscopists. Incisions were repaired with a running, delayed absorbable suture. Subject demographics and clinical variables were collected and surgical outcomes analyzed. Median age and body mass index were 45 years and 30 kg/m(2), respectively. Approximately half of study subjects underwent a hysterectomy with or without salpingo-oophorectomy, and 15% had a diagnosis of cancer. Overall, 0.9% of women were diagnosed with a preoperative umbilical hernia, and 2.4% of women experienced a major perioperative complication. After a median postoperative follow-up time of 16 months, 2.4% had development of an umbilical hernia. However, 4/5 of these women had significant risk factors for fascial weakening independent of LESS, including requirement for a second abdominal surgery in 1 subject and a cancer diagnosis with postoperative chemotherapy administration in 2 subjects. When these subjects deemed "high risk" for incisional disruption were excluded from the analysis, the umbilical hernia rate was 0.5% (1/207). On univariable analysis, obesity was the only factor associated with complications (p = .04). When performed by advanced laparoscopic surgeons, laparoendoscopic single-site gynecologic surgery is associated with a low risk of major adverse events. Additionally, the overall umbilical hernia rate was 2.4% and was lower (0.5%) in subjects without significant comorbidities. Copyright © 2012 AAGL. Published by Elsevier Inc. All rights reserved.

  13. Human umbilical cord tissue-derived mesenchymal stromal cells attenuate remodeling after myocardial infarction by proangiogenic, antiapoptotic, and endogenous cell-activation mechanisms

    PubMed Central

    2014-01-01

    Introduction Among the plethora of cells under investigation to restore a functional myocardium, mesenchymal stromal cells (MSCs) have been granted considerable interest. However, whereas the beneficial effects of bone marrow MSCs (BM-MSCs) in the context of the diseased heart are widely reported, data are still scarce on MSCs from the umbilical cord matrix (UCM-MSCs). Herein we report on the effect of UCM-MSC transplantation to the infarcted murine heart, seconded by the dissection of the molecular mechanisms at play. Methods Human umbilical cord tissue-derived MSCs (UCX®), obtained by using a proprietary technology developed by ECBio, were delivered via intramyocardial injection to C57BL/6 females subjected to permanent ligation of the left descending coronary artery. Moreover, medium produced by cultured UCX® preconditioned under normoxia (CM) or hypoxia (CMH) was collected for subsequent in vitro assays. Results Evaluation of the effects upon intramyocardial transplantation shows that UCX® preserved cardiac function and attenuated cardiac remodeling subsequent to myocardial infarction (MI). UCX® further led to increased capillary density and decreased apoptosis in the injured tissue. In vitro, UCX®-conditioned medium displayed (a) proangiogenic activity by promoting the formation of capillary-like structures by human umbilical vein endothelial cells (HUVECs), and (b) antiapoptotic activity in HL-1 cardiomyocytes subjected to hypoxia. Moreover, in adult murine cardiac Sca-1+ progenitor cells (CPCs), conditioned medium enhanced mitogenic activity while activating a gene program characteristic of cardiomyogenic differentiation. Conclusions UCX® preserve cardiac function after intramyocardial transplantation in a MI murine model. The cardioprotective effects of UCX® were attributed to paracrine mechanisms that appear to enhance angiogenesis, limit the extent of the apoptosis, augment proliferation, and activate a pool of resident CPCs. Overall, these results

  14. Suture versus tack fixation of mesh in laparoscopic umbilical hernia repair.

    PubMed

    Kitamura, Riley K; Choi, Jacqueline; Lynn, Elizabeth; Divino, Celia M

    2013-01-01

    Mesh fixation in laparoscopic umbilical hernia repair is poorly studied. We compared postoperative outcomes of laparoscopic umbilical hernia repair in suture versus tack mesh fixation. Patients who underwent laparoscopic umbilical hernia repair were separated by method of mesh fixation: sutures versus primarily tacks. Medical history and follow-up data were collected through medical records. The primary outcome of this study was the recurrence rates of hernias. Postoperative major and minor complications, such as surgical site infection, small-bowel obstruction, and seroma formation, were regarded as secondary outcomes. Additionally, a telephone interview was conducted to assess postoperative pain, recovery time, and overall patient satisfaction. Eighty-six patients were identified: 33 in the suture group and 53 in the tacks group. The number of emergent cases was increased in the tacks group (6 vs 0; P = .022). Mean follow-up time was 2.7 years for both groups. Documented postoperative follow-up was obtained in 29 (90%) suture group and 31 (58%) tacks group patients. Hernia recurrence occurred in 3 and 2 patients in the sutures and tacks groups, respectively (P was not significant). No differences were found in secondary outcomes, including subjective outcomes from telephone interviews, between groups. There are no differences in postoperative complication rates in suture versus tack mesh fixation in laparoscopic umbilical hernia repair.

  15. A matter of health? Legal aspects of private umbilical cord blood banking.

    PubMed

    Vidalis, Takis

    2011-03-01

    Private umbilical cord blood banking raises a question of special legal regulation. This practice promises the safe storage of biological material on the assumption that it may be useful, at a certain moment in future, for its own donor (or for a donor's close family member) for curing serious blood diseases. Although currently the therapeutic value of umbilical cord blood is confirmed, there are strong scientific doubts and relevant controversies regarding its use in autologous transplantations. This fact produces conditions of legal uncertainty, since the benefit for those wanting to conclude contracts with private umbilical cord blood banks is not clear. The Greek example illustrates this situation of regulatory deficit well, which eventually creates a major problem, given the increasing number of private banks offering relevant services in the country.

  16. [Effectiveness of Sacral Intervertebral Epidural Block for Umbilical Hernia Repair in Children].

    PubMed

    Nagamine, Norimitsu; Furuya, Atsushi; Suzuki, Sho; Kondo, Satoko; Kiuchi, Riko; Suzuki, Satomi; Nonaka, Akihiko

    2015-02-01

    Effectiveness of sacral intervertebral epidural block (S 2-3 block) for umbilical hernia repair has not been clarified. We investigate 24 children, undergoing umbilical hernia repair; mean age of 3 years (age range: 20-65 months). Under general anesthesia, epidural block was performed at S 2-3 interspace with 1 ml x kg(-1) ropivacaine (0.2%) at injecting rate of 1 ml x sec(-1) followed by 0.25 ml x kg(-1) normal saline. In all cases, neither systolic blood pressure nor heart rate increased > 15% from those just before the block. Postoperative analgesics were given in 6 patients (25%) rectally. Mean time between the block and the administration of analgesic was 10.5 hours. S 2-3 block can be effective for postoperative pain in umbilical hernia repair.

  17. VITAL SIGNS AND FIRST OCCURRENCES IN NORMAL AND ABNORMAL NEWBORN ASIAN ELEPHANT ( ELEPHAS MAXIMUS) CALVES.

    PubMed

    Wiedner, Ellen; Kiso, Wendy K; Aria, Janice; Isaza, Ramiro; Lindsay, William; Jacobson, Gary; Jacobson, Kathy; Schmitt, Dennis

    2017-12-01

    Sixteen years of medical records documenting 19 births within a herd of Asian elephants ( Elephas maximus) at a private facility in the southeastern United States were reviewed. Of the 19 calves, 11 were normal at birth, requiring no additional veterinary care, and eight were abnormal, requiring veterinary care immediately or within the first week of birth. Descriptive statistics were used to evaluate morphometrics, vital signs, and behavioral milestones in newborn calves both normal and abnormal. Blood work and urinalysis results from all calves were compared to values for adult elephants. Medical management of abnormal calves is described. All calves had faster heart rates and respiratory rates than did adult elephants, but rectal temperatures were the same. Calves were precocious with regard to sitting and standing but could be very slow to nurse. The most-common medical conditions of newborn calves were umbilical abnormalities and problems associated with nursing. Two calves required cardiopulmonary resuscitation after birth but made full recoveries. Some conditions were not apparent at birth but were recognized a few hours or days later. Following veterinary intervention, six of the eight calves made full recoveries, suggesting that early identification and treatment of problems can greatly decrease mortality. This is the first report of multiple veterinary and behavioral parameters in normal and abnormal neonatal Asian elephants from a facility with a calf survival rate above 90%. This information may be helpful to other elephant-holding facilities in providing care to their newborn elephant calves.

  18. Estimation of shear stress by using a myocardial bridge-mural coronary artery simulating device.

    PubMed

    Ding, Hao; Yang, Qian; Shang, Kun; Lan, Hailian; Lv, Jie; Liu, Zhilin; Liu, Yang; Sheng, Lixing; Zeng, Yanjun

    2017-01-01

    This study was aimed at developing a myocardial bridge-mural coronary artery simulative device and analyzing the relationship between shear stress on the mural coronary artery and atherosclerosis. A myocardial bridge-mural coronary artery simulative device was used to simulate experiments in vitro. In the condition of maintaining any related parameters such as system temperature, average flow rate, and heart rate, we calculated and observed changes in proximal and distal mean values, and oscillatory value of shear stress on the mural coronary artery by regulating the compression level of the myocardial bridge to the mural coronary artery. Under 0% compression, no significant differences were observed in distal and proximal mean values and oscillatory value of the shear stress on the mural coronary artery. With the increase in the degree of compression, the mean shear stress at the distal end was greater than that at the proximal end, but the oscillatory value of the shear stress at the proximal end was greater than that at the distal end. The experimental results of this study indicate that myocardial bridge compression leads to abnormal hemodynamics at the proximal end of the mural coronary artery. This abnormal phenomenon is of great significance in the study of atherosclerosis hemodynamic pathogenesis, which has potential clinical value for pathological effects and treatments of myocardial bridge.

  19. Orion Service Module Umbilical (OSMU) Testing Complete

    NASA Image and Video Library

    2016-10-19

    Testing of the Orion Service Module Umbilical (OSMU) was completed at the Launch Equipment Test Facility at NASA’s Kennedy Space Center in Florida. The OSMU was attached to Vehicle Motion Simulator 1 for a series of simulated launch tests to validate it for installation on the mobile launcher. The test team gathered for an event to mark the end of testing. The mobile launcher tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. Kennedy's Engineering Directorate is providing support to the Ground Systems Development and Operations Program for testing of the OSMU. EM-1 is scheduled to launch in 2018.

  20. Orion Service Module Umbilical (OSMU) Testing Complete

    NASA Image and Video Library

    2016-10-19

    Testing of the Orion Service Module Umbilical (OSMU) was completed at the Launch Equipment Test Facility at NASA’s Kennedy Space Center in Florida. The OSMU was attached to Vehicle Motion Simulator 1 for a series of simulated launch tests to validate it for installation on the mobile launcher. The test team signed a special banner during an event to mark the end of testing. The mobile launcher tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. Kennedy's Engineering Directorate is providing support to the Ground Systems Development and Operations Program for testing of the OSMU. EM-1 is scheduled to launch in 2018.

  1. [Pooled Umbilical Cord Blood Plasma for Culturing UCMSC and Ex Vivo Expanding Umbilical Cord Blood CD34⁺ Cells].

    PubMed

    Wu, Jie-Ying; Lu, Yan; Chen, Jin-Song; Wu, Shao-Qing; Tang, Xue-Wei; Li, Yan

    2015-08-01

    To investigate the feasibility of umbilical cord blood plasma (UCP) as a replacement for fetal bovine serum (FBS) for culturing mesenchymal stem cells (MSC) derived from umbilical cord, and to observe the supporting effects of these cells (served as a feeder layer) on ex vivo expanding of human umbilical cord blood CD34(+) cells. Umbilical cord blood (UCB) units were suitable if the Guangzhou cord blood bank donor selection criteria strictly were fulfilled. UCP were ready to use after the collection from the plasma depletion/reduction during the processing and pooling of suitable UCB units (at least 30 units were screened for pathogens and microorganisms, and qualified). Umbilical cord mesenchymal stem cells (UCMSC) were harvested from the umbilical cord tissue of health full-term newborns after delivery by enzyme digestion and divided into 3 groups: group 1 and 2 were cultured in the presence of DMEM/F12 containing either FBS or UCP; and group 3 was cultured in serum-free medium (StemPro® MSC SFM CTS™). Morphology, proliferation and surface marker expression were examined by flow cytometry, and the differentiation toward adipogenic and osteogenic lineages was used for investigating the effect of media on UCMSC after 3-5 passages. Next, the cells cultured in the three different media were cryopreserved and thawed, then prepared as feeder layers with the name of UCMSC(FBS), UCMSC(UCP), and UCMSC(SFM), respectively. The CD34⁺ cells were separated from UCB by magnetic activated cell sorting (MACS) and divided into 4 groups cultured in StemPro(-34) SFM medium added with hematopoietic cytokine combination (StemSpan® CC100). The control group included only CD34⁺ cells as group A (blank control) and experimental groups included UCMSC(FBS) + CD34⁺ cells as group B, UCMSC(UCP) + CD34⁺ cells as group C, UCMSC(SFM) + CD34⁺ cells as group D, and cells in all groups were cultured ex vivo for 7 days. The nucleated cell (NC) number was counted by cell counter, CD34

  2. Fenestrations and Various Duplications of the Posterior Communicating Artery in the Prenatal and Postnatal Periods.

    PubMed

    Trandafilović, Milena; Vasović, Ljiljana; Vlajković, Slobodan; Đorđević, Gordana; Stojanović, Borisav; Mladenović, Marija

    2016-07-01

    The 2 paired arteries-the posterior communicating arteries (PCoAs) and the precommunicating parts of the posterior cerebral arteries-form the so-called posterior segment of the cerebral arterial circle on the base of the brain. A number of (ab)normal morphologic features were described in the literature (e.g., unusual kinking, or extreme elongations, hypoplasia, duplications, fenestrations, the infundibular widening, or aplasia of the PCoA in the prenatal and/or postnatal periods). The aim of this study was to analyze an incidence of various fenestrations and duplications of the PCoA, and describe their general features and their association with other vascular abnormalities. The research was performed on the brains of 200 human fetuses and 377 adult cadavers of both genders and different ages using microdissection and macrodissection methods. There were 0.34% cases with PCoA fenestrations and 3.12% cases with various PCoA duplications. Their morphologic features were described and compared with the similar PCoA abnormalities recorded in the scientific literature. There was no association between the PCoA and either duplication or aneurysm in adult cases. After thorough examination, the fenestrations and duplications of the PCoA are distinguished as 2 special forms of vascular abnormalities, and the PCoA duplications are characterized as partial and total. Furthermore, whereas the low incidence of a fenestration of the PCoA suggests it to be a sufficiently rare phenomenon, the duplications of the PCoA trunk are fairly frequent, especially concerning its terminal segment. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Umbilical hernia alloplastic dual-mesh treatment in cirrhotic patients

    PubMed Central

    Guriță, RE; Popa, F; Bălălău, C; Scăunașu, RV

    2013-01-01

    Rationale. Abdominal wall hernias represent a pathology with an impressive prevalence among the population of patients with cirrhosis complicated by ascites. The aggressive surgical approach of umbilical hernia for patients with cirrhotic background remains a controversial problem, accompanied by anesthetic and surgical risk. Its indication remains fully justified in case of severe symptoms or life threatening complications: strangulation, incarceration, evisceration. Objective. This article evaluates results obtained by using dual-mesh alloplastic materials for surgical treatment of umbilical hernias affecting cirrhotic patients with incipient liver injury. Methods and Results. Our lot consists of twelve patients with ages between 45 and 65 years, diagnosed with hepatic cirrhosis, without other associated comorbidities. All patients were admitted for strangulated umbilical hernia. Among the analyzed lot, no decease was encountered, the morbidity being limited to two cases of parietal suppuration, solved conservatively, without the mesh removal. There were no ascitic fistulas. No recurrences were registered for a 12 months tracking period. Discussion. The presence of cirrhosis implies a high anesthetic and surgical risk, the intervention being grafted by a substantial increase of mortality and morbidity in an emergency setting. The development of new alloplastic materials, together with the modern anesthetic techniques, allows superior results for patients with incipient hepatic injury. PMID:23599831

  4. Fracture and Collapse of Balloon-Expandable Stents in the Bilateral Common Iliac Arteries Due to Shiatsu Massage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ichihashi, Shigeo, E-mail: shigeoichihashi@yahoo.co.jp; Higashiura, Wataru; Itoh, Hirofumi

    2012-12-15

    We report a case of stent fracture and collapse of balloon-expandable stents caused by shiatsu massage. A 76-year-old man presented with complaints of intermittent claudication of the right lower extremity. Stenoses of the bilateral common iliac arteries (CIAs) were detected. Balloon-expandable stents were deployed in both CIAs, resulting in resolution of symptoms. Five months later, pelvis x-ray showed collapse of both stents. Despite the stent collapse, the patient was asymptomatic, and his ankle brachial index values were within the normal range. Further history showed that the patient underwent daily shiatsu therapy in the umbilical region, which may have triggered collapsemore » of the stent. Physicians should advise patients to avoid compression of the abdominal wall after implantation of a stent in the iliac artery.« less

  5. Clinical accuracy of non-contact infrared thermometer from umbilical region in children: A new side.

    PubMed

    Apa, Hurşit; Gözmen, Salih; Keskin-Gözmen, Şükran; Aslan, Fatma; Bayram, Nuri; Devrim, İlker

    2016-01-01

    Measurement from axillary site with digital thermometer has been accepted as the most accurate method. But this method is time consuming. Tympanic and forehead measurements are often used but don't always seem to be more appropriate. Another site, umbilical region, could be an alternative site. This study aims to compare the measurements with axillary digital thermometer and non-contact infrared thermometers at sites from umbilicus and forehead to determine whether umbilical site could be used accurately in children. For each method, 2,048 measurements in total were performed. Using axillary method as gold standard, with a cut-off temperature of 38oC, the sensitivities and specificities, positive and negative predictive values of umbilical and forehead temperatures and area under the ROC curve were determined in non obese children. There was a significant positive correlation between axillary and umbilical temperatures with a correlation coefficient of 0.78. The average difference between the mean of both axillary and umbilical temperatures was -0.47 ± 0.65°C. The Bland-Altman plot showed good accuracy with only 2.5 % of the readings falling outside the 95% level of confidence. Umbilical measurements showed sensitivity of 71.7% and specificity of 95.8%. The area under the ROC curve was 0.93. The easy application may lead noncontact measurements from umbilicus site to be the preferable method for health care providers, but agreement limits mentioned in this study should be considered.

  6. Continuous neonatal blood gas monitoring using a multiparameter intra-arterial sensor

    PubMed Central

    Morgan, C; Newell, S; Ducker, D; Hodgkinson, J; White, D; Morley, C; Church, J

    1999-01-01

    AIMS—To compare arterial blood gas (ABG) readings obtained with a multiparameter intra-arterial sensor with those from an ABG analyser.
METHODS—An MPIAS with the ability to measure continuously pH, PaCO2, and PaO2 was introduced via an umbilical arterial catheter in 27 neonates requiring intensive care. They underwent 3260 hours of MPIAS monitoring, during which 753 ABG readings were performed.
RESULTS—Overall bias (mean difference: MPIAS-ABG) and precision (standard deviation of differences) values were: −0.002 and 0.022,respectively, for pH; +0.26 and 0.52 for PaCO2 (kPa); and −0.19 and 0.99 for PaO2 (kPa). This gave 95% limits of agreement as: −0.047 to +0.042 for pH, −0.76 to +1.28 kPa for PaCO2, and −2.13 to +1.75 kPa for PaO2. For each variable, precision across readings from the same individual was better than overall precision for all data. No complications related to the use of the catheter were observed.
CONCLUSIONS—Continuous MPIAS ABG monitoring is an exciting development, with the potential to reduce blood transfusions and improve ABG homeostasis.

 PMID:10325783

  7. Delivery route determines the presence of immune complexes on umbilical cord erythrocytes.

    PubMed

    de Lima, Andrés; Franco, Luis C; Sarmiento, Andrés; González, John M

    2017-11-01

    Umbilical cord blood offers a unique opportunity to study the basal level of immunoglobulin complexes. This study aims to determine the presence of immune complexes and complement deposition on erythrocytes from umbilical cord blood from normal, full-term pregnancies. In vitro pre-formed IgA, IgG, and IgM complexes were used as positive control for flow cytometry detection, and for C3d deposition. Blood samples (34) of umbilical cord blood taken from vaginal and cesarean deliveries were tested for the presence of immunoglobulin complexes. Fourteen samples from vaginal deliveries and 20 samples from cesarean deliveries were assessed. IgG and IgM complexes were detected on erythrocytes, whereas no IgA complexes or complement deposition was observed. Interestingly, the percentage of IgG complexes was higher on erythrocytes from vaginal delivery samples compared to those from cesarean deliveries. No other associations between immune complexes and other maternal or newborn variables were found. IgG and IgM complexes seem to be normally present on umbilical cord erythrocytes. Erythrocytes from vaginal deliveries have a higher percentage of IgG complexes present compared to that from cesarean deliveries. Since no C3d activity was detected, these complexes are non-pathological and should be part of the newborn's initial innate immune response.

  8. Clinicopathologic features and surgical management of primary umbilical melanoma: a case series.

    PubMed

    Di Monta, Gianluca; Caracò, Corrado; Marone, Ugo; Grimaldi, Antonio Maria; Anniciello, Anna Maria; Di Marzo, Massimiliano; Simeone, Ester; Mori, Stefano

    2015-04-15

    Primary umbilical melanoma is an uncommon tumor that is poorly described in the medical literature. The umbilical region is a particular anatomic site owing to the presence of embryonal remnants, which can be a potential metastatic pathway, as well as the braided lymphatic network drainage. Hence, primary malignant neoplasms affecting the umbilicus require a different and more radical surgical approach compared with other melanomas. In this report, we describe a series of three patients of Caucasian ethnicity who presented with primary umbilical melanoma at the National Cancer Institute of Naples, Italy. All patients underwent wide excision of the tumor including the underlying peritoneum. No surgical complications, either immediate or delayed, were observed in any of the patients. Sentinel lymph node biopsy was negative in two cases. Two of the patients developed metastatic disease and died after systemic medical therapy. The other patient is currently in follow-up, and remains disease-free after 21 months. The umbilicus has vascular and embryological connections with the underlying peritoneum, so that early visceral involvement is more likely to occur with primary umbilical melanomas. As such, tumor resection including the underlying peritoneum is required to avoid local relapse, whilst sentinel lymph node biopsy appears to be of poor diagnostic value.

  9. Cardiac Abnormalities in Primary Hyperoxaluria

    PubMed Central

    Mookadam, Farouk; Smith, Travis; Jiamsripong, Panupong; Moustafa, Sherif E; Monico, Carla G.; Lieske, John C.; Milliner, Dawn S.

    2018-01-01

    Background In patients with primary hyperoxaluria (PH), oxalate overproduction can result in recurrent urolithiasis and nephrocalcinosis, which in some cases results in a progressive decline in renal function, oxalate retention, and systemic oxalosis involving bone, retina, arterial media, peripheral nerves, skin, and heart. Oxalosis involving the myocardium or conduction system can potentially lead to heart failure and fatal arrhythmias. Methods and Results A retrospective review of our institution’s database was conducted for all patients with a confirmed diagnosis of PH between 1/1948 and 1/2006 (n=103). Electrocardiogram (ECG) and echocardiography were used to identify cardiac abnormalities. Ninety-three patients fulfilled the inclusion criteria, 58% were male. Mean follow-up was 11.9 (median 8.8) years. In 38 patients who received an ECG or echocardiography, 31 were found to have any cardiac abnormalities. Cardiac findings correlated with decline in renal function. Conclusions Our data suggests that physicians caring for patients with PH should pay close attention to cardiac status, especially if renal function is impaired. PMID:20921818

  10. Effect of low-sodium diet on uteroplacental circulation.

    PubMed

    Delemarre, F M; van Leest, L A; Jongsma, H W; Steegers, E A

    2000-01-01

    To study the influence of chronic dietary sodium restriction on uteroplacental circulation. In a randomized trial, Doppler flow velocity waveforms of the uterine and umbilical artery were studied at monthly intervals during pregnancy in 59 women on a low-sodium diet and in 68 controls. Pulsatility index (PI), resistance index (RI), and A/B ratio of the uterine artery were significantly lower during sodium restriction, whereas PI, RI, and A/B ratio of the umbilical artery were significantly higher. The lower resistance indices of the uterine artery during sodium restriction might reflect an increase in pulse pressure/impedance ratio as a result of activation of the renin-angiotensin system. The increase in umbilical artery resistance indices supports the hypothesis that fetal circulation might be altered by chronic dietary sodium restriction.

  11. Parasympathetic tone variations according to umbilical cord pH at birth: a computerized fetal heart rate variability analysis.

    PubMed

    Butruille, Laura; De Jonckheere, Julien; Flocteil, Mathilde; Garabedian, Charles; Houfflin-Debarge, Véronique; Storme, Laurent; Deruelle, Philippe; Logier, Régis

    2017-12-01

    Non-reassuring fetal heart rate tracings reflect an imbalance between the parasympathetic and sympathetic nervous systems. In this situation, fetal asphyxia can be suspected and may be confirmed by metabolic measurements at birth like low pH or high base deficit values. The objective of this study was to determine whether fetal asphyxia during labor is related to parasympathetic nervous system activity. This is a retrospective study of a database collected in 5 centers. Two hundred and ninety-nine fetal heart rate tracings collected during labor were analyzed. Autonomic nervous system, especially the parasympathetic nervous system, was analyzed using an original index: the FSI (Fetal Stress Index). The FSI is a parasympathetic activity evaluation based on fetal heart rate variability analysis. Infants were grouped based on normal or low pH value at birth. FSI was measured during the last 30 min of labor before birth and compared between groups. The minimum value of the FSI during the last 30 min before delivery was significantly lower in the group with the lower umbilical cord arterial pH value. In this pilot study during labor, FSI was lower in the group of infants with low arterial pH at birth.

  12. Cross-sectional relations of arterial stiffness, pressure pulsatility, wave reflection, and arterial calcification.

    PubMed

    Tsao, Connie W; Pencina, Karol M; Massaro, Joseph M; Benjamin, Emelia J; Levy, Daniel; Vasan, Ramachandran S; Hoffmann, Udo; O'Donnell, Christopher J; Mitchell, Gary F

    2014-11-01

    , abnormal central arterial hemodynamics were positively associated with vascular calcification and were observed at younger ages than previously recognized. The mechanisms of these associations may be bidirectional and deserve further study. © 2014 American Heart Association, Inc.

  13. Prehepatocholedochal proper hepatic artery. Rare anatomical variant. Surgical considerations. Case report.

    PubMed

    Ardeleanu, V; Chicoş, S; Tutunaru, D; Georgescu, C

    2014-01-01

    In classical anatomic variants, the proper hepatic artery (PHA)continues the common hepatic artery (CHA) after the gastroduodenal artery (GDA) detaches itself and divides into the right hepatic artery (RHA) and left hepatic artery (LHA), the proper hepatic artery being located to the left of the hepatocholedochal duct (HCD). This paper presents an abnormal positioning of the PHA placed before the HCD with an increased diameter of about 5-7 mm, which could be confused with the HCD. We present the case of a 57 year-old woman diagnosed with acute lithiasic cholecystitis, associated with hypersplenism and hypertension. The literature mentions manifold anatomical variants of arterial liver vascularization,including PHA. For this reason, this paper presents an overview of similar cases that can be found in medical literature. The aforementioned case is a rare topographic anatomy for the PHA that can easily pass for HCD especially during celioscopy, therefore it is crucial for this to be acknowledged by all surgeons. Celsius.

  14. Interventional Management of Massive Hemothorax Due to Inadvertent Puncture of an Aberrant Right Subclavian Artery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jahnke, Thomas, E-mail: thomas.jahnke@gmx.net; Schaefer, Phillip Jost; Heller, Martin

    2008-07-15

    We report a case of massive hemothorax due to inadvertent puncture of an aberrant right subclavian artery during central venous access. Iatrogenic laceration at the origin of the right internal thoracic artery was successfully treated with coil embolization of the internal thoracic artery followed by stent-graft placement into the subclavian artery. Due to its elongated and abnormal course, an aberrant right subclavian artery may predispose to inadvertent puncture during vein catheterization and should be recognized as a potential threat for such procedures. Our case emphasizes that ultrasound guidance should be used routinely for central venous lines wherever possible.

  15. Inflammation and immunity in the pathogenesis of pulmonary arterial hypertension.

    PubMed

    Rabinovitch, Marlene; Guignabert, Christophe; Humbert, Marc; Nicolls, Mark R

    2014-06-20

    This review summarizes an expanding body of knowledge indicating that failure to resolve inflammation and altered immune processes underlie the development of pulmonary arterial hypertension. The chemokines and cytokines implicated in pulmonary arterial hypertension that could form a biomarker platform are discussed. Pre-clinical studies that provide the basis for dysregulated immunity in animal models of the disease are reviewed. In addition, we present therapies that target inflammatory/immune mechanisms that are currently enrolling patients, and discuss others in development. We show how genetic and metabolic abnormalities are inextricably linked to dysregulated immunity and adverse remodeling in the pulmonary arteries. © 2014 American Heart Association, Inc.

  16. What has methylmercury in umbilical cords told us? - Minamata disease.

    PubMed

    Yorifuji, Takashi; Kashima, Saori; Tsuda, Toshihide; Harada, Masazumi

    2009-12-20

    Severe methylmercury poisoning occurred in Minamata and neighboring communities in the 1950s and 1960s. The exposed patients manifested neurological signs, and some patients exposed in utero were born with so-called congenital Minamata disease. In a previous report, Nishigaki and Harada evaluated the methylmercury concentrations in the umbilical cords of inhabitants and demonstrated that methylmercury actually passed through the placenta (Nishigaki and Harada, 1975). However, the report involved a limited number of cases (only 35) and did not quantitatively evaluate the regional differences in the transition of methylmercury exposure. Therefore, in the present study, we evaluated the temporal and spatial distributions of methylmercury concentrations in umbilical cords, with an increased number of participants and additional descriptive analyses. Then, we examined whether the methylmercury concentrations corresponded with the history of the Minamata disease incident. A total of 278 umbilical cord specimens collected after birth were obtained from babies born between 1925 and 1980 in four study areas exposed to methylmercury. Then, we conducted descriptive analyses, and drew scatterplots of the methylmercury concentrations of all the participants and separated by the areas. In the Minamata area, where the first patient was identified in 1956, the methylmercury concentration reached a peak around 1955. Subsequently, about 5 years later, the concentrations peaked in other exposed areas with the expected exposure distribution corresponding with acetaldehyde production (the origin of methylmercury). This historical incident several decades ago in Minamata and neighboring communities clearly shows that regional pollution affected the environment in utero. Furthermore, the temporal and spatial distributions of the methylmercury concentrations in the umbilical cords tell us the history of the Minamata disease incident.

  17. A Review of Factors Influencing the Banking of Collected Umbilical Cord Blood Units

    PubMed Central

    Allan, David; Petraszko, Tanya; Elmoazzen, Heidi; Smith, Susan

    2013-01-01

    Umbilical cord blood banking efforts have increased dramatically in the past two decades in response to increasing demand for alternative sources of blood stem cells to support patients requiring hematopoietic stem cell transplantation. Transplant centres have accumulated increasing expertise in their understanding of umbilical cord blood characteristics that are associated with improved outcome following transplantation. These characteristics and factors can assist transplant centres in selecting cord blood units from the worldwide inventory of banked units. Umbilical cord blood banks, therefore, need to remain agile in adjusting the inventory of the banks to address shifts or changes in the needs of transplant centres. Public umbilical cord blood banks face the challenge of building inventory while managing limited resources and are faced with decisions regarding which units can be stored and which units that have been collected should be discarded or used for other endeavours such as research. To this end, we sought to review parameters influencing the decision to bank a collected cord blood unit. In this paper, we will address parameters associated with graft potency and address other factors that guide the decision to bank collected units. PMID:23533442

  18. Comparison of umbilical cord ghrelin concentrations in full-term pregnant women with or without gestational diabetes.

    PubMed

    Karakulak, Murat; Saygili, Uğur; Temur, Muzaffer; Yilmaz, Özgür; Özün Özbay, Pelin; Calan, Mehmet; Coşar, Hese

    2017-05-01

    Ghrelin is a potent orexigenic peptide hormone secreted from the gastrointestinal tract that plays a crucial role in the regulation of lipids and glucose metabolism. Ghrelin also has links with fetal development and growth. Gestational diabetes mellitus (GDM) causes fetal macrosomia, but there is no available evidence of a relationship between ghrelin levels and birth weight in women with GDM. The purpose of this study is to investigate whether umbilical cord ghrelin concentrations are altered in full-term pregnant women with GDM compared to women without GDM and whether birth weight is correlated with ghrelin levels. Sixty pregnant women with GDM and 64 healthy pregnant women without GDM were included in this cross-sectional study. Blood samples were drawn from the umbilical vein following birth. Ghrelin concentrations were measured using enzyme-linked immunosorbent assay (ELISA). Umbilical vein ghrelin levels were decreased in women with GDM (879.6 ± 256.1 vs. 972.2 ± 233.6 pg/ml in women without GDM, p=0.033), whereas birth weights were higher for babies in the GDM than in the non-GDM group (3448 ± 410 vs. 3308 ± 365 gr, respectively, p=0.046). Umbilical ghrelin levels were inversely correlated with birth weight (r=-0.765, p<0.001). Multiple regression analysis revealed that birth weight was independently and negatively associated with umbilical ghrelin levels (β= -2.077, 95% CI=-2.652 to -1.492, p=0.002). Umbilical ghrelin levels were lower in GDM women. Birth weight was inversely associated with umbilical ghrelin levels. This association may be explained by a negative feedback mechanism between ghrelin and birth weight.

  19. Incarceration of umbilical hernia: a rare complication of large volume paracentesis.

    PubMed

    Khodarahmi, Iman; Shahid, Muhammad Usman; Contractor, Sohail

    2015-09-01

    We present two cases of umbilical hernia incarceration following large volume paracentesis (LVP) in patients with cirrhotic ascites. Both patients became symptomatic within 48 hours after the LVP. Although being rare, given the significantly higher mortality rate of cirrhotic patients undergoing emergent herniorrhaphy, this complication of LVP is potentially serious. Therefore, it is recommended that patients be examined closely for the presence of umbilical hernias before removal of ascitic fluid and an attempt should be made for external reduction of easily reducible hernias, if a hernia is present.

  20. Incarceration of umbilical hernia: a rare complication of large volume paracentesis

    PubMed Central

    Khodarahmi, Iman; Shahid, Muhammad Usman; Contractor, Sohail

    2015-01-01

    We present two cases of umbilical hernia incarceration following large volume paracentesis (LVP) in patients with cirrhotic ascites. Both patients became symptomatic within 48 hours after the LVP. Although being rare, given the significantly higher mortality rate of cirrhotic patients undergoing emergent herniorrhaphy, this complication of LVP is potentially serious. Therefore, it is recommended that patients be examined closely for the presence of umbilical hernias before removal of ascitic fluid and an attempt should be made for external reduction of easily reducible hernias, if a hernia is present. PMID:26629305

  1. [Long-term follow-up results after open small umbilical hernia repairs].

    PubMed

    Malý, O; Sotona, O

    2014-04-01

    Adult umbilical hernia is a common surgical condition in the fifth and sixth decade of life. Despite the high frequency of umbilical hernia repairs, disappointingly high recurrence rates after simple suture repairs are reported, amounting to 54%. In addition, it is reported that with the rising frequency of recurrences, the size of the hernial sac and gate gradually increases. Therefore we decided to find out the incidence of recurrences after operative repair of an umbilical hernia at our department. Patient data for this retrospective study focusing on the period between 2006 and 2010 were obtained from the electronic hospital database. Patients with umbilical hernia and the abdominal wall defect up to 3 cm who underwent primary elective procedure were included in the study. Patients with incisional hernias were excluded. All patients were contacted at least 3 years after operation to confirm the accuracy of data. A total of 127 patients were included in this study. In the abovementioned period, no mesh was used during primary surgery in any of the patients. Recurrence occurred in a total of 13.4% of patients. Approximately 40% of patients with the first recurrence were re-operated at our department, 30% of patients were re-operated in other hospitals and the rest have not sought medical attention in respect of the recurrence. Patients with recurrence did not differ from the others as regards age, body mass index or surgical site infection development. Due to the high recurrence rates after operative sutures of the umbilical hernias there is a need to thoroughly consider the potential risk factors such as the body mass index and the abdominal wall defect size. Therefore, it is recommended to use the mesh more widely during primary surgery, especially in obese patients with BMI over 30 and the wall defect size exceeding 3 cm. The question remains whether to use the mesh in all overweight patients and with wall defect smaller than 3 cm.

  2. Abnormalities of vascular histology and collagen fiber configuration in patients with advanced chronic kidney disease.

    PubMed

    Allon, Michael; Litovsky, Silvio H; Tey, Jason Chieh Sheng; Sundberg, Chad A; Zhang, Yingying; Chen, Zhen; Fang, Yun; Cheung, Alfred K; Shiu, Yan-Ting

    2018-05-01

    Several histologic features have been identified in the upper-extremity arteries and veins of patients with advanced chronic kidney disease, which may affect arteriovenous fistula maturation. However, it is unclear whether these chronic kidney disease vascular features are abnormal. We obtained upper-extremity arterial and venous specimens from 125 advanced chronic kidney disease patients undergoing arteriovenous fistula creation and from 15 control subjects. We quantified medial fibrosis, micro-calcification, and intimal hyperplasia with appropriate histology stains. We characterized medial collagen fiber configuration in second-harmonic-generation microscopy images for the fiber anisotropy index and the dominant fiber direction. The advanced chronic kidney disease patients were significantly younger than control subjects (53 ± 14 years vs 76 ± 11 years, p < 0.001). After controlling for age, the chronic kidney disease patients had greater arterial medial fibrosis (69% ± 14% vs 51% ± 10%, p < 0.001) and greater arterial micro-calcification (3.03% ± 5.17% vs 0.01% ± 0.03%, p = 0.02), but less arterial intimal thickness (30 ± 25 µm vs 63 ± 25 µm, p < 0.001), as compared to control subjects. The anisotropy index of medial collagen fibers was lower in both arteries (0.24 ± 0.10 vs 0.44 ± 0.04, p < 0.001) and veins (0.28 ± 0.09 vs 0.53 ± 0.10, p < 0.001) in chronic kidney disease patients, indicating that orientation of the fibers was more disordered. The dominant direction of medial collagen fibers in chronic kidney disease patients was greater in the arteries (49.3° ± 23.6° vs 4.0° ± 2.0°, p < 0.001) and the veins (30.0° ± 19.6° vs 3.9° ± 2.1°, p < 0.001), indicating that the fibers in general were aligned more perpendicular to the lumen. Advanced chronic kidney disease is associated with several abnormalities in vascular histology and

  3. Hypertension, obesity, and coronary artery disease in the survivors of congenital heart disease.

    PubMed

    Roche, S Lucy; Silversides, Candice K

    2013-07-01

    Obesity, hypertension, and coronary artery disease are prevalent in the general population and well recognized as contributors to cardiac morbidity and mortality. With surgical and medical advances, there is a growing and aging population with congenital heart disease who are also at risk of developing these comorbidities. In addition, some congenital cardiac lesions predispose patients to conditions such as hypertension or coronary artery disease. The effect of these comorbidities on the structurally abnormal heart is not well understood, but might be very important, especially in those with residual abnormalities. Thus, in addition to surveillance for and treatment of late complications it is important for the congenital cardiologist to consider and aggressively manage acquired comorbidities. In this review we explore the prevalence of hypertension, obesity, and coronary artery disease, discuss congenital lesions that predispose to these conditions and review management strategies for this unique population. Copyright © 2013 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  4. Outcome of sublay mesh repair in non-complicated umbilical hernia with liver cirrhosis and ascites.

    PubMed

    Hassan, Ahmed Mohamed Abdelaziz; Salama, Asaad Fayrouz; Hamdy, Hussam; Elsebae, Magdy Mohamed; Abdelaziz, Ayman Mohamed; Elzayat, Wessam Abdelrahman

    2014-01-01

    Umbilical hernia repair is often accompanied by complications in patients with liver cirrhosis and ascites. It appears that the early elective repair of umbilical hernias in these patients is safer and can be considered for selected patients. The objective of this study is to evaluate the feasibility, safety, complications and technical aspects of sublay mesh repair of umbilical hernia in cirrhotic patients with ascites. Between October 2010 and April 2013, 70 patients with non-complicated umbilical hernia, liver cirrhosis and ascites were enrolled in this study. All patients underwent sublay mesh repair. Demographic data, preoperative variables, peri-operative course, and postoperative complications were recorded and analyzed. A total of 38 women and 32 men underwent operation at an average age 51.24 years. The patients mean MELD score was 18 (range 12-25). The mean operative time was 67.45 min and the average hospital stay was 3.8 days. 2 patients had wound infection, 3 patients developed seroma and 1 patient had an ascitic fistula. Recurrence occurred in 1 (1.4%) patient and no mortality related to the procedure. elective sublay umbilical hernia mesh repair is a safe approach and feasible technique in selected non-complicated cirrhotic patients with ascites. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  5. Spontaneous endometriosis associated with an umbilical hernia: A case report and review of the literature.

    PubMed

    Ismael, Hishaam; Ragoza, Yury; Harden, Angela; Cox, Steven

    2017-01-01

    Umbilical endometriosis occurring in the presence of an underlying hernia is extremely rare and presents a diagnostic challenge for the general surgeon. We present an interesting case and perform a comprehensive review of the literature. Medline and PubMed were queried for all cases of spontaneous umbilical endometriosis associated with an umbilical hernia. Data was analyzed and is presented along with an interesting case. Only 7 cases have been reported in the literature. Median age was 38 years. Time to presentation was long (up to 5 years) and the majority had cyclical symptoms related to menstruation. All patients, including our case, were treated surgically. Spontaneous umbilical endometriosis with an underlying hernia is often missed preoperatively. Preoperative suspicion warrants axial imaging for better operative planning and patient counseling. Surgery consists of enbloc excision of the umbilicus, implant and the hernia sac to avoid residual disease and reduce recurrence. The hernia defect can be repaired primarily or using mesh and the umbilicus reconstructed using skin flaps if necessary. Surgery is the mainstay of therapy for umbilical endometriosis associated with an underlying hernia. Clinical suspicion warrants preoperative imaging, and follow-up with a gynecologist is essential to address any pelvic disease. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Cerebral Perforating Artery Disease : Characteristics on High-Resolution Magnetic Resonance Imaging.

    PubMed

    Liang, Jianye; Liu, Yiyong; Xu, Xiaoshuang; Shi, Changzheng; Luo, Liangping

    2018-03-23

    Our aims were to evaluate the feasibility of high-resolution magnetic resonance imaging (HR-MRI) for displaying the cerebral perforating arteries in normal subjects and to discuss the value of HR-MRI for detecting the causes of infarctions in the territory of the lenticulostriate artery (LSA). Included in this study were 31 healthy subjects and 28 patients who had infarctions in the territory supplied by the LSA. The T1-weighted imaging (T1WI), T2WI, diffusion-weighted imaging (DWI), and HR-MRI, including 3‑dimensional time-of-flight magnetic resonance angiography (3D-TOF-MRA) and 3D fast spin-echo T1WI (namely CUBE T1 in GE Healthcare), were applied on a 3-Tesla scanner. The numbers and route of the perforating arteries on both sides were independently confirmed on HR-MRI by two physicians. The Wilcoxon test was used to compare the differences. The numbers of perforating arteries in healthy subjects observed on 3D-TOF-MRA were as follows: numbers of the bilateral recurrent artery of Heubner (RAH) ranged from 0-3 (median 1), numbers of the left LSA ranged from 0-7 (median 3), numbers of the right LSA ranged from 0-5 (median 3), numbers of the bilateral anterior choroidal artery ranged from 1-2 (median 1) and the numbers of the bilateral thalamoperforating artery ranged from 1-2 (median 1). In the patients with lenticulostriate infarctions, the numbers of LSAs on the affected side were lower than on the opposite and ipsilateral sides in the healthy subjects. The results were statistically significant. An abnormality of the RAH may lead to a centrum semiovale infarct pattern, whereas an abnormality of the LSA is associated with a corona radiata infarct pattern. The use of HR 3D-TOF-MRA and CUBE T1 had unique advantages in displaying the tiny perforating arteries in vivo. Moreover, effective recognition of the associated cerebral perforating artery and infarct patterns may enhance our understanding of the mechanism of stroke in patients with lenticulostriate

  7. Triple dye plus rubbing alcohol versus triple dye alone for umbilical cord care.

    PubMed

    Suliman, Alawia K; Watts, Heidi; Beiler, Jessica; King, Tonya S; Khan, Sana; Carnuccio, Marybeth; Paul, Ian M

    2010-01-01

    Current practices for umbilical cord care vary across centers, but the evidence regarding these practices and their impact on cord separation, complications, and health care use are limited. The objective of this study was to compare the effect of triple dye alone (brilliant green, crystal violet, and proflavine hemisulfate) versus triple dye plus rubbing alcohol (isopropyl alcohol) twice daily on time to umbilical cord separation, complications, and health care use. For the 90 newborns who completed the study, there were no significant differences between treatment groups for time to cord separation, cord-related morbidities, or cord-related urgent care. Based on these study results, there does not appear to be significant benefit to the addition of twice daily applications of rubbing alcohol to neonatal umbilical cords following triple dye treatment after birth.

  8. Management of bleeding from an abnormally located S6 arterial branch in a common origin with S2 branch during live surgery.

    PubMed

    Abu Akar, Firas; Gonzalez-Rivas, Diego; Fink, Daniel

    2016-01-01

    In 24 th /03/2016 we organized the first uniportal video-assisted thoracic surgery (VATS) live surgery workshop in Jerusalem at our institution with our special guest Dr. Diego Gonzalez-Rivas, more than 30 participants attended this workshop from Israeli and the Palestinian territories (cardiothoracic and vascular surgeons, general surgeons, anesthesiologists and nurses). During the workshop Dr. Gonzalez operated two complex cases while the first case was an anatomical S1 segmentectomy, the second case (the one which we are reporting in this paper) was bilobectomy of right middle and lower lobes, during this case a profuse bleeding appeared while introducing the stapler in the interlobar fissure, the source of this bleeding was an abnormally located arterial branch, however the bleeding managed perfectly by Dr. Gonzalez-Rivas, although this surgery kept all of us in a state, all the attendees were happy to see the way how this bleeding managed and everybody was satisfied with the final result.

  9. Management of bleeding from an abnormally located S6 arterial branch in a common origin with S2 branch during live surgery

    PubMed Central

    Gonzalez-Rivas, Diego; Fink, Daniel

    2016-01-01

    In 24th/03/2016 we organized the first uniportal video-assisted thoracic surgery (VATS) live surgery workshop in Jerusalem at our institution with our special guest Dr. Diego Gonzalez-Rivas, more than 30 participants attended this workshop from Israeli and the Palestinian territories (cardiothoracic and vascular surgeons, general surgeons, anesthesiologists and nurses). During the workshop Dr. Gonzalez operated two complex cases while the first case was an anatomical S1 segmentectomy, the second case (the one which we are reporting in this paper) was bilobectomy of right middle and lower lobes, during this case a profuse bleeding appeared while introducing the stapler in the interlobar fissure, the source of this bleeding was an abnormally located arterial branch, however the bleeding managed perfectly by Dr. Gonzalez-Rivas, although this surgery kept all of us in a state, all the attendees were happy to see the way how this bleeding managed and everybody was satisfied with the final result. PMID:29399474

  10. Human umbilical cord mesenchymal stromal cells in regenerative medicine.

    PubMed

    Detamore, Michael S

    2013-11-25

    Cells of the human umbilical cord offer tremendous potential for improving human health. Cells from the Wharton’s jelly (umbilical cord stroma) in particular, referred to as human umbilical cord mesenchymal stromal cells (HUCMSCs), hold several advantages that make them appealing for translational research. In the previous issue of Stem Cell Research & Therapy, Chon and colleagues made an important contribution to the HUCMSC literature not only by presenting HUCMSCs as an emerging cell source for intervertebral disc regeneration in general and the nucleus pulposus in particular, but also by demonstrating that an extracellular matrix-based strategy might be preferred over the use of growth factors. By culturing HUCMSCs under hypoxia in serum-free conditions in the presence of Matrigel with laminin-111, they were able to achieve intense collagen II staining by 21 days without the addition of exogenous growth factors. There is tremendous translational significance here in that such raw materials may alleviate the need for the use of growth factors in some instances, and this may have important ramifications in reducing product cost and streamlining regulatory approval. Chon and colleagues provide a promising example of the potential of HUCMSCs, demonstrating the ability to guide HUCMSC differentiation even in the absence of serum and growth factors and supporting the use of HUCMSCs as a viable alternative in intervertebral disc regeneration.

  11. Mycophenolate mofetil attenuates pulmonary arterial hypertension in rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suzuki, Chihiro; Takahashi, Masafumi; Morimoto, Hajime

    Pulmonary arterial hypertension (PAH) is characterized by abnormal proliferation of smooth muscle cells (SMCs), leading to occlusion of pulmonary arterioles, right ventricular (RV) hypertrophy, and death. We investigated whether mycophenolate mofetil (MMF), a potent immunosuppresssant, prevents the development of monocrotaline (MCT)-induced PAH in rats. MMF effectively decreased RV systolic pressure and RV hypertrophy, and reduced the medial thickness of pulmonary arteries. MMF significantly inhibited the number of proliferating cell nuclear antigen (PCNA)-positive cells, infiltration of macrophages, and expression of P-selectin and interleukin-6 on the endothelium of pulmonary arteries. The infiltration of T cells and mast cells was not affected bymore » MMF. In vitro experiments revealed that mycophenolic acid (MPA), an active metabolite of MMF, dose-dependently inhibited proliferation of human pulmonary arterial SMCs. MMF attenuated the development of PAH through its anti-inflammatory and anti-proliferative properties. These findings provide new insight into the potential role of immunosuppressants in the treatment of PAH.« less

  12. Mycobacterium fortuitum Infection at Umbilical Hernioplasty Site

    PubMed Central

    Chogtu, Bharti; Malik, Daliparty Vasudev; Shenoy, Vishnu Prasad

    2017-01-01

    Non Tuberculous Mycobacteria (NTM) are a group of rapidly growing mycobacteria and are generally considered to be of low virulence. Of late, there has been an increase in incidence of infections due to these organisms. Among them, Mycobacterium fortuitum, M. chelonae and M. abscessus are the common species which have been identified. Though they are occasionally implicated in pulmonary infections, NTM are very commonly associated with cutaneous infections, especially surgical site infections. Identification of NTM infection at such sites should be suspected when there is delayed healing of the wound. Histopathological Examination (HPE) of the wound site may reveal a classical picture of granulomas, epithelioid cells and giant cells which may lead to a suspicion of tuberculosis. It is important to perform mycobacterial culture and sensitivity testing of the wound tissue as this helps to differentiate tuberculous and non tuberculous infections. Here, we present a case of a patient who underwent mesh hernioplasty for umbilical hernia and was diagnosed with M. fortuitum infection at the site of umbilical hernioplasty. PMID:29207758

  13. Orion Service Module Umbilical (OSMU) Testing Complete

    NASA Image and Video Library

    2016-10-19

    Testing of the Orion Service Module Umbilical (OSMU) was completed at the Launch Equipment Test Facility at NASA’s Kennedy Space Center in Florida. The OSMU was attached to Vehicle Motion Simulator 1 for a series of simulated launch tests to validate it for installation on the mobile launcher. Patrick Simpkins, director of Engineering, speaks to the test team during an event to mark the end of testing. The mobile launcher tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. Kennedy's Engineering Directorate is providing support to the Ground Systems Development and Operations Program for testing of the OSMU. EM-1 is scheduled to launch in 2018.

  14. Orion Service Module Umbilical (OSMU) Testing Complete

    NASA Image and Video Library

    2016-10-19

    Testing of the Orion Service Module Umbilical (OSMU) was completed at the Launch Equipment Test Facility at NASA’s Kennedy Space Center in Florida. The OSMU was attached to Vehicle Motion Simulator 1 for a series of simulated launch tests to validate it for installation on the mobile launcher. The test team gathered with a special banner during an event to mark the end of testing. The mobile launcher tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. Kennedy's Engineering Directorate is providing support to the Ground Systems Development and Operations Program for testing of the OSMU. EM-1 is scheduled to launch in 2018.

  15. Orion Service Module Umbilical (OSMU) Testing Complete

    NASA Image and Video Library

    2016-10-19

    Testing of the Orion Service Module Umbilical (OSMU) was completed at the Launch Equipment Test Facility at NASA’s Kennedy Space Center in Florida. The OSMU was attached to Vehicle Motion Simulator 1 for a series of simulated launch tests to validate it for installation on the mobile launcher. One of the test team members signs a banner during an event to mark the end of testing. The mobile launcher tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. Kennedy's Engineering Directorate is providing support to the Ground Systems Development and Operations Program for testing of the OSMU. EM-1 is scheduled to launch in 2018.

  16. Robotic-assisted laparoscopic prostatectomy in umbilical hernia patients: University of California, Irvine, technique for port placement and repair.

    PubMed

    Kim, William; Abdelshehid, Corollos; Lee, Hak J; Ahlering, Thomas

    2012-06-01

    To discuss a technique currently used at our institution for the management of umbilical hernias during robot-assisted laparoscopic prostatectomy. As more patients undergo robot-assisted radical prostatectomy, there will be an increase in patients who qualify for robotic surgery with comorbidities. This technique has been utilized in clinically localized prostate cancer patients with umbilical hernias using the da Vinci Surgical System and standard laparoscopic instrumentation. Port placements and closures were performed by a resident assistant and a nurse at the operating table. The prostatectomy was performed by a single experienced surgeon at the console. Currently, no data are available regarding patients with umbilical hernias undergoing robotic prostatectomy. We reviewed our technique of port placement for patients with a pre-existing umbilical hernia undergoing robot-assisted laparoscopic prostatectomy. This technique allows for a reduction of the umbilical hernia, the use of the fascial defect as a robotic port, and the removal of the prostate by way of transverse incision and transverse repair. In our experience, this technique is feasible and reproducible for any small or large umbilical hernia. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Outcome by Exercise Echocardiography in Patients with Low Pretest Probability of Coronary Artery Disease.

    PubMed

    Peteiro, Jesus; Bouzas-Mosquera, Alberto; Broullon, Javier; Sanchez-Fernandez, Gabriel; Perez-Cebey, Lucia; Yañez, Juan; Martinez, Dolores; Vazquez-Rodriguez, Jose M

    2016-08-01

    Recommendations for testing in patients with low pretest probability of coronary artery disease differ in guidelines from no testing at all to different tests. The aim of this study was to assess the value of exercise echocardiography (ExE) to define outcome in this population. A retrospective analysis was conducted of 1,436 patients with low pretest probability of coronary artery disease (<15%) who underwent initial ExE. Overall mortality, major adverse cardiac events (MACEs), defined as cardiac death or nonfatal myocardial infarction, and revascularization during follow-up, were assessed. Ischemia (development of new wall motion abnormalities with exercise) and fixed wall motion abnormalities were measured. The mean age was 50 ± 12 years. Resting wall motion abnormalities were seen in 13 patients (0.9%) and ischemia in 108 (7.5%). During follow-up, 38 patients died, 10 of cardiac death (annualized death rate, 0.39%); 20 patients had MACEs (annualized MACE rate, 0.21%); and 48 patients (29 with ischemia) underwent revascularization (annualized revascularization rate, 0.51%). The number and percentage of MACEs in the abnormal and normal ExE groups were similar (two [1.7%] vs 18 [1.4%], P = .70), as was the annualized MACE rate (0.31% vs 0.21%, P = .50). Peak left ventricular ejection fraction exhibited a nonsignificant trend for predicting MACEs (P = .11). The number of studies needed to detect an abnormal finding was 12.6 and to detect a patient with extensive ischemia was 26.1. ExE offers limited prognostic information in patients with low pretest probability of coronary artery disease. The small number of abnormal findings on ExE and low event rates and the large number of studies needed to detect an abnormal finding limit further the value of imaging in this population. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  18. Armored umbilical apparatus for towing a marine seismic air gun sub array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burrage, E.C.

    1985-06-25

    An armored umbilical and termination housing is disclosed for towing a sub-array of seismic air guns used in marine seismic surveying comprising a single air hose for supplying all the high pressure air to the individual air guns surrounded by all the electrical control cables needed to operate the air guns in the sub-array. Protective coatings are applied around the electrical control cables and stress members for carrying the load of towing the sub-array are incorporated within the umbilical. A termination housing is provided on the end of the umbilical for terminating the single air hose and all the electricalmore » control lines to common connectors so that individual electrical control lines and air hoses can run from the termination housing to each individual air gun in the sub-array. Air shut off valves are provided so that the high pressure air can be shut off to the individual air guns within the sub-array remotely from the survey vessel.« less

  19. Laparoscopic umbilical hernia repair in a cirrhotic patient with a peritoneovenous shunt.

    PubMed

    Umemura, Akira; Suto, Takayuki; Sasaki, Akira; Fujita, Tomohiro; Endo, Fumitaka; Wakabayashi, Go

    2015-05-01

    A 62-year-old Japanese woman who had developed massive cirrhotic ascites was referred to our hospital for a peritoneovenous shunt implant. However, CT examination revealed an umbilical hernia that had not been observed before the peritoneovenous shunt was implanted. We decided to perform laparoscopic umbilical hernia repair to keep carbon dioxide from flowing backward into the central circulatory system. We first clamped the catheter and set the upper limit of the pneumoperitoneum pressure to 6 mmHg. The central venous pressure was also measured simultaneously. Mesh was then applied over the hernia and fixed by the double-crown technique. Finally, 1000-mL physiological saline was infused into the abdominal cavity while the pneumoperitoneum was slowly released. In this case, we safely performed laparoscopic umbilical hernia repair while making some alterations, specifically catheter clamping, reducing pneumoperitoneum pressure, monitoring central venous pressure, and infusing physiological saline. © 2014 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  20. Sildenafil Citrate Increases Fetal Weight in a Mouse Model of Fetal Growth Restriction with a Normal Vascular Phenotype

    PubMed Central

    Dilworth, Mark Robert; Andersson, Irene; Renshall, Lewis James; Cowley, Elizabeth; Baker, Philip; Greenwood, Susan; Sibley, Colin Peter; Wareing, Mark

    2013-01-01

    Fetal growth restriction (FGR) is defined as the inability of a fetus to achieve its genetic growth potential and is associated with a significantly increased risk of morbidity and mortality. Clinically, FGR is diagnosed as a fetus falling below the 5th centile of customised growth charts. Sildenafil citrate (SC, Viagra™), a potent and selective phosphodiesterase-5 inhibitor, corrects ex vivo placental vascular dysfunction in FGR, demonstrating potential as a therapy for this condition. However, many FGR cases present without an abnormal vascular phenotype, as assessed by Doppler measures of uterine/umbilical artery blood flow velocity. Thus, we hypothesized that SC would not increase fetal growth in a mouse model of FGR, the placental-specific Igf2 knockout mouse, which has altered placental exchange capacity but normal placental blood flow. Fetal weights were increased (by 8%) in P0 mice following maternal SC treatment (0.4 mg/ml) via drinking water. There was also a trend towards increased placental weight in treated P0 mice (P = 0.056). Additionally, 75% of the P0 fetal weights were below the 5th centile, the criterion used to define human FGR, of the non-treated WT fetal weights; this was reduced to 51% when dams were treated with SC. Umbilical artery and vein blood flow velocity measures confirmed the lack of an abnormal vascular phenotype in the P0 mouse; and were unaffected by SC treatment. 14C-methylaminoisobutyric acid transfer (measured to assess effects on placental nutrient transporter activity) per g placenta was unaffected by SC, versus untreated, though total transfer was increased, commensurate with the trend towards larger placentas in this group. These data suggest that SC may improve fetal growth even in the absence of an abnormal placental blood flow, potentially affording use in multiple sub-populations of individuals presenting with FGR. PMID:24204949

  1. Lysyl Oxidase Induces Vascular Oxidative Stress and Contributes to Arterial Stiffness and Abnormal Elastin Structure in Hypertension: Role of p38MAPK

    PubMed Central

    Martínez-Revelles, Sonia; García-Redondo, Ana B.; Avendaño, María S.; Varona, Saray; Palao, Teresa; Orriols, Mar; Roque, Fernanda R.; Fortuño, Ana; Touyz, Rhian M.; Martínez-González, Jose; Salaices, Mercedes

    2017-01-01

    Abstract Aims: Vascular stiffness, structural elastin abnormalities, and increased oxidative stress are hallmarks of hypertension. Lysyl oxidase (LOX) is an elastin crosslinking enzyme that produces H2O2 as a by-product. We addressed the interplay between LOX, oxidative stress, vessel stiffness, and elastin. Results: Angiotensin II (Ang II)-infused hypertensive mice and spontaneously hypertensive rats (SHR) showed increased vascular LOX expression and stiffness and an abnormal elastin structure. Mice over-expressing LOX in vascular smooth muscle cells (TgLOX) exhibited similar mechanical and elastin alterations to those of hypertensive models. LOX inhibition with β-aminopropionitrile (BAPN) attenuated mechanical and elastin alterations in TgLOX mice, Ang II-infused mice, and SHR. Arteries from TgLOX mice, Ang II-infused mice, and/or SHR exhibited increased vascular H2O2 and O2.− levels, NADPH oxidase activity, and/or mitochondrial dysfunction. BAPN prevented the higher oxidative stress in hypertensive models. Treatment of TgLOX and Ang II-infused mice and SHR with the mitochondrial-targeted superoxide dismutase mimetic mito-TEMPO, the antioxidant apocynin, or the H2O2 scavenger polyethylene glycol-conjugated catalase (PEG-catalase) reduced oxidative stress, vascular stiffness, and elastin alterations. Vascular p38 mitogen-activated protein kinase (p38MAPK) activation was increased in Ang II-infused and TgLOX mice and this effect was prevented by BAPN, mito-TEMPO, or PEG-catalase. SB203580, the p38MAPK inhibitor, normalized vessel stiffness and elastin structure in TgLOX mice. Innovation: We identify LOX as a novel source of vascular reactive oxygen species and a new pathway involved in vascular stiffness and elastin remodeling in hypertension. Conclusion: LOX up-regulation is associated with enhanced oxidative stress that promotes p38MAPK activation, elastin structural alterations, and vascular stiffness. This pathway contributes to vascular abnormalities in

  2. Impact of aspirin on trophoblastic invasion in women with abnormal uterine artery Doppler at 11-14 weeks: a randomized controlled study.

    PubMed

    Scazzocchio, E; Oros, D; Diaz, D; Ramirez, J C; Ricart, M; Meler, E; González de Agüero, R; Gratacos, E; Figueras, F

    2017-04-01

    Defective trophoblastic invasion is a key feature in many cases of pre-eclampsia (PE). Uterine artery (UtA) Doppler is a validated non-invasive proxy for trophoblastic invasion. The aim of this study was to explore whether low-dose aspirin, administered from the first trimester, improves trophoblastic invasion, evaluated by UtA Doppler during the second and third trimesters in women defined as high risk by abnormal first-trimester UtA Doppler. This randomized Phase-II study had a triple-blind, parallel-arm, controlled design. Singleton pregnancies with abnormal mean UtA Doppler at 11-14 weeks and absence of other major risk factors for PE received 150 mg extended-release aspirin or identical-appearing placebo tablets from study inclusion to 28 weeks. Main outcome measure was UtA pulsatility index (PI) at 28 weeks' gestation. Secondary outcomes included frequency of development of PE and growth restriction/small-for-gestational age (SGA). A total of 155 women completed the follow-up and were analyzed. No difference in mean UtA-PI was found between women in the aspirin and placebo groups at 28 weeks (mean UtA-PI Z-score (mean ± SD), 0.99 ± 1.48 vs 0.85 ± 1.25; P = 0.52). Seven women developed PE: four (5%) in the aspirin group and three (4%) in the placebo group. There was a trend toward lower incidence of SGA in the aspirin group (8.8% vs 17.3%; P = 0.11). In women with defective trophoblastic invasion, as reflected by abnormal UtA Doppler, low-dose aspirin started in the first trimester does not have a significant effect on UtA impedance as pregnancy progresses; however, the study was underpowered to detect potential small effects . Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

  3. Preoperative ultrasonographic findings of internal jugular veins and carotid arteries in kidney transplant recipients.

    PubMed

    Choi, Ji Won; Kim, Gaab Soo; Lee, Seung Won; Park, Jeong Bo; Lee, Jeong Jin; Ko, Justin Sangwook

    2016-08-01

    Hemodialysis via the internal jugular vein (IJV) has been widely used for patients with end stage renal disease (ESRD) patients, as they have a higher risk of arterial diseases. We investigated the ultrasonographic findings of the IJV and carotid artery (CA) in recipients of kidney transplantation (KT) and identified factors influencing IJV/CA abnormalities. We enrolled 120 adult KT recipients. Patients in group A (n = 57) had a history of IJV hemodialysis, while those in group B (n = 63) were not yet on dialysis or undergoing dialysis methods not involving the IJV. The day before surgery, we evaluated the state of the IJV and CA using ultrasonography. We followed patients with IJV stenosis for six months after KT. Ultrasonography revealed that four patients (7%) in group A had IJV abnormalities, while no patients in group B had abnormalities (P = 0.118). Of the four patients with abnormalities, one with 57.4% stenosis normalized during follow- up. However, another patient with 90.1% stenosis progressed to occlusion, while the two patients with total occlusion remained the same. Twenty patients in group A (n = 11) and B (n = 9) had several CA abnormalities (P = 0.462). Upon multivariate analysis with stepwise selection, height and age were significantly correlated with IJV stenosis (P = 0.043, odds ratio = 0.9) and CA abnormality (P = 0.012, odds ratio = 1.1), respectively. IJV abnormalities (especially with a history of IJV hemodialysis) and CA abnormalities may be present in ESRD patients. Therefore, we recommend ultrasonographic evaluation before catheterization.

  4. Acquired umbilical hernias in four captive polar bears (Ursus maritimus).

    PubMed

    Velguth, Karen E; Rochat, Mark C; Langan, Jennifer N; Backues, Kay

    2009-12-01

    Umbilical hernias are a common occurrence in domestic animals and humans but have not been well documented in polar bears. Surgical reduction and herniorrhaphies were performed to correct acquired hernias in the region of the umbilicus in four adult captive polar bears (Ursus maritimus) housed in North American zoos. Two of the four bears were clinically unaffected by their hernias prior to surgery. One bear showed signs of severe discomfort following acute enlargement of the hernia. In another bear, re-herniation led to acute abdominal pain due to gastric entrapment and strangulation. The hernias in three bears were surgically repaired by debridement of the hernia ring and direct apposition of the abdominal wall, while the large defect in the most severely affected bear was closed using polypropylene mesh to prevent excessive tension. The cases in this series demonstrate that while small hernias may remain clinically inconsequential for long periods of time, enlargement or recurrence of the defect can lead to incarceration and acute abdominal crisis. Umbilical herniation has not been reported in free-ranging polar bears, and it is suspected that factors such as body condition, limited exercise, or enclosure design potentially contribute to the development of umbilical hernias in captive polar bears.

  5. Mesh repair of umbilical hernia without a visible abdominal scar.

    PubMed

    Kurpiewski, Waldemar; Kiliańczyk, Michał; Szynkarczuk, Rafał; Tenderenda, Michał

    2014-02-01

    Experience in the use of Single Incision Laparoscopic Surgery procedures and the persistent urge to improve the cosmetic effect have contributed to the introduction of mesh repair of an umbilical hernia by means of a small incision in the natural position of the umbilicus. The aim of the study was to present the surgical technique and assess its postoperative results. During the period between 24.08.2011 and 01.01.2013, twenty-three umbilical hernia repair operations with the use of a polypropylene mesh by means of a small incision in the natural position of the umbilicus were performed. The synthetic material was placed in the preperitoneal space. The wound was closed and the umbilicus was reconstructed simultaneously, in order to make the scar invisible. Cutaneous stitches were not used. The average duration of the operation was 49 minutes. In one case of an obese patient with coexisting linea alba dehiscence, hernia recurrence was observed. All wounds healed without complications. The cosmetic effect was very good. Based on the presented experience mesh repair of the umbilical hernia by means of a small incision in the natural position of the umbilicus contributes essential benefits, such as a very good cosmetic effect without consecutive increasing costs, as compared to standard treatment by means of an infraumbilical incision.

  6. Simultaneous isolation of vascular endothelial cells and mesenchymal stem cells from the human umbilical cord.

    PubMed

    Kadam, Sachin S; Tiwari, Shubha; Bhonde, Ramesh R

    2009-01-01

    The umbilical cord represents the link between mother and fetus during pregnancy. This cord is usually discarded as a biological waste after the child's birth; however, its importance as a "store house" of stem cells has been explored recently. We developed a method of simultaneous isolation of endothelial cells (ECs) from the vein and mesenchymal stem cells from umbilical cord Wharton's jelly of the same cord. The isolation protocol has been simplified, modified, and improvised with respect to choice of enzyme and enzyme mixture, digestion time, cell yield, cell growth, and culture medium. Isolated human umbilical vascular ECs (hUVECs) were positive for von-Willibrand factor, a classical endothelial marker, and could form capillary-like structures when seeded on Matrigel, thus proving their functionality. The isolated human umbilical cord mesenchymal stem cells (hUCMSCs) were found positive for CD44, CD90, CD 73, and CD117 and were found negative for CD33, CD34, CD45, and CD105 surface markers; they were also positive for cytoskeleton markers of smooth muscle actin and vimentin. The hUCMSCs showed multilineage differentiation potential and differentiated into adipogenic, chondrogenic, osteogenic, and neuronal lineages under influence of lineage specific differentiation medium. Thus, isolating endothelial cells as well as mesenchymal cells from the same umbilical cord could lead to complete utilization of the available tissue for the tissue engineering and cell therapy.

  7. Umbilical cord sparing technique for repair of congenital hernia into the cord and small omphalocele.

    PubMed

    Ceccanti, Silvia; Falconi, Ilaria; Frediani, Simone; Boscarelli, Alessandro; Musleh, Layla; Cozzi, Denis A

    2017-01-01

    Current repair of small omphaloceles and hernias into the umbilical cord is a straightforward procedure, whose repair may result in a suboptimal cosmetic outcome. We describe a novel repair technique retaining the umbilical cord elements in an attempt to improve the cosmetic appearance of the umbilicus. Eight neonates were consecutively treated more than a ten-year period. Size of the fascial defects ranged 1 to 3cm (median, 2). Present technique entails incision of the amniotic sac without its detachment from the skin, reduction of the extruded contents under direct vision, and closure of the abdominal wall defect by circumferential suturing of peritoneum and fascia around the base of the amniotic sac. The amniotic sac is then re-approximated and folded to create an umbilical stump, which is trimmed and left to shed naturally. All patients achieved a scarless abdomen with a normal appearing umbilicus in 6. The remaining 2 patients are awaiting surgery for persisting umbilical hernia repair and umbilicoplasty, respectively. Poor esthetic outcome was significantly associated with initial fascial defect ≥2.5cm in size (p=0.03). Present technique is a simple and cosmetically appealing repair for umbilical cord hernias and small omphaloceles, especially effective when the size of the fascial defect is less than 2.5cm. IV (Treatment Study). Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Mid-term Risk for Subclinical Atherosclerosis and Chronic Myocarditis in Children with Kawasaki Disease and Transient Coronary Abnormalities.

    PubMed

    Parihar, Mansingh; Singh, Surjit; Vignesh, Pandiarajan; Gupta, Anju; Rohit, Manojkumar

    2017-08-01

    There is evidence for premature atherosclerosis and systemic arterial stiffening during follow-up of children with Kawasaki disease (KD) and coronary artery abnormalities (CAA). Moreover, patients with KD may also have subclinical myocardial involvement and inhomogeneous ventricular repolarization. The inhomogeneous ventricular repolarization manifests as increased QT dispersion on electrocardiography. There is a paucity of studies in endothelial dysfunction and QT dispersion in children with KD and transient CAA. Twenty children with KD and transient CAA were studied at least 1 year after resolution of CAA. Mean follow-up period between KD onset and enrolment in the study was 53.7 months. Twenty age and sex-matched controls were enrolled. High-resolution B-mode ultrasonography was used to analyze brachial artery dilatation in response to reactive hyperemia (cases and controls) and sublingual nitroglycerine (cases only). Carotid artery intima-media thickness (cIMT) and stiffness index were calculated. The difference between maximum and minimum QTc intervals on 12 lead electrocardiogram was calculated as QTc dispersion (QTcd). No statistically significant difference was noted in percent flow-mediated dilatation of brachial arteries in response to reactive hyperemia between cases (13.31 ± 10.41%) and controls (12.86 ± 7.09%). Sublingual nitroglycerine-mediated dilatation in children with KD was 14.88 ± 12.03%. Mean cIMT was similar in cases (0.036 ± 0.015 cm) and controls (0.035 ± 0.076 cm; p = 0.791). No statistically significant difference between groups was observed in mean QTcd values (0.057 ± 0.018 s vs. 0.059 ± 0.015 s in controls, p = 0.785). No evidence of significant endothelial dysfunction or increased QT dispersion in patients with KD and transient coronary artery abnormalities was found in our cohort when studied at a mean follow-up of 53.7 months. This is reassuring, and indicates that risk of subclinical atherosclerosis

  9. Potential pitfalls and methods of improving in utero diagnosis of transposition of the great arteries, including the baby bird's beak image.

    PubMed

    McGahan, John P; Moon-Grady, Anita J; Pahwa, Anokh; Towner, Dena; Rhee-Morris, Laila; Gerscovich, Eugenio O; Fogata, Maria

    2007-11-01

    The goal of this study was to analyze our recent experience with fetuses with transposition of the great arteries (TGA) to identify potential pitfalls and possible methods to better detect conotruncal anomalies such as TGA. We analyzed all nonreferral obstetric ultrasound examinations in which we performed basic, targeted, or formal fetal echocardiography with a newborn diagnosis of TGA. Nine neonates had TGA. Five of these cases were diagnosed prenatally, and 4 of these had complex congenital heart abnormalities. In these 4 cases, there were abnormalities in the cardiac axis (n = 3), abnormal valves or ventricular size (n = 2), and ventricular septal defects (n = 3) that were detected on the 4-chamber view of the heart. In all cases that were not detected prenatally, both prospective and retrospective reviews of the 4-chamber heart appeared normal. The prospective analyses of the outflow tracts were all interpreted as normal, whereas the retrospective review showed subtle abnormalities such as the "baby bird's beak" image. In review of these cases, there was failure to show the "crisscross" relationship of the outflow tracts. In 1 case, 5 short axis views of the heart, retrospectively showed the artery originating from the left ventricle and bifurcated, representing the pulmonary artery. Transposition of the great arteries may be associated with complex cardiac disease that could be detected on the 4-chamber view of the heart. When the 4-chamber view is normal, it is important to identify the crisscross relationship of the outflow tracts. If this is not done, it is important to document that the pulmonary artery bifurcates and originates from the right ventricle. Five short axis views of the heart may be helpful to detect conotruncal abnormalities.

  10. Myocardial perfusion abnormalities in asymptomatic patients with systemic lupus erythematosus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hosenpud, J.D.; Montanaro, A.; Hart, M.V.

    1984-08-01

    Accelerated coronary artery disease and myocardial infarction in young patients with systemic lupus erythematosus is well documented; however, the prevalence of coronary involvement is unknown. Accordingly, 26 patients with systemic lupus were selected irrespective of previous cardiac history to undergo exercise thallium-201 cardiac scintigraphy. Segmental perfusion abnormalities were present in 10 of the 26 studies (38.5 percent). Five patients had reversible defects suggesting ischemia, four patients had persistent defects consistent with scar, and one patient had both reversible and persistent defects in two areas. There was no correlation between positive thallium results and duration of disease, amount of corticosteroid treatment,more » major organ system involvement or age. Only a history of pericarditis appeared to be associated with positive thallium-201 results (p less than 0.05). It is concluded that segmental myocardial perfusion abnormalities are common in patients with systemic lupus erythematosus. Whether this reflects large-vessel coronary disease or small-vessel abnormalities remains to be determined.« less

  11. Prognosis elements in surgical treatment of complicated umbilical hernia in patients with liver cirrhosis.

    PubMed

    Banu, P; Popa, F; Constantin, V D; Bălălău, C; Nistor, M

    2013-09-15

    The surgical treatment of umbilical hernia in cirrhosis patients raises special management challenges. The attitude upon the repair of these hernias varies from expectancy or elective treatment in early stages of the disease to the surgical treatment only if complications occur. We have assessed 22 consecutive cases of cirrhosis patients treated for complicated umbilical hernia in the Surgical Department of "Sf. Pantelimon" Emergency Hospital in Bucharest between January 2008 and December 2012. The patients' stratification was done in stages of liver disease based upon Child-Pugh classification. Complications that required emergency repair were the following: strangulation, incarceration and hernia rupture. The postoperative complications were ordered in five grades of severity based upon Clavien classification. The severity of the complications was higher in advanced stages of liver cirrhosis, Child B and C. There were 5 deaths representing 22,7%, four of them in patients with Child C disease stage. The incidence of morbidity and mortality after umbilical hernia repair in emergencies increases in advanced stages of liver cirrhosis. It is advisable to prevent complications occurrence and perform surgical repair of umbilical hernia in elective condition.

  12. Probabilistic Design Methodology and its Application to the Design of an Umbilical Retract Mechanism

    NASA Technical Reports Server (NTRS)

    Onyebueke, Landon; Ameye, Olusesan

    2002-01-01

    A lot has been learned from past experience with structural and machine element failures. The understanding of failure modes and the application of an appropriate design analysis method can lead to improved structural and machine element safety as well as serviceability. To apply Probabilistic Design Methodology (PDM), all uncertainties are modeled as random variables with selected distribution types, means, and standard deviations. It is quite difficult to achieve a robust design without considering the randomness of the design parameters which is the case in the use of the Deterministic Design Approach. The US Navy has a fleet of submarine-launched ballistic missiles. An umbilical plug joins the missile to the submarine in order to provide electrical and cooling water connections. As the missile leaves the submarine, an umbilical retract mechanism retracts the umbilical plug clear of the advancing missile after disengagement during launch and retrains the plug in the retracted position. The design of the current retract mechanism in use was based on the deterministic approach which puts emphasis on factor of safety. A new umbilical retract mechanism that is simpler in design, lighter in weight, more reliable, easier to adjust, and more cost effective has become desirable since this will increase the performance and efficiency of the system. This paper reports on a recent project performed at Tennessee State University for the US Navy that involved the application of PDM to the design of an umbilical retract mechanism. This paper demonstrates how the use of PDM lead to the minimization of weight and cost, and the maximization of reliability and performance.

  13. Comparison between open and closed methods of herniorrhaphy in calves affected with umbilical hernia

    PubMed Central

    Hossain, Mohammad Farhad; Das, Bhajan Chandra; Kim, Gonhyung; Hossain, Mohammad Alamgir

    2009-01-01

    Umbilical hernias in calves commonly present to veterinary clinics, which are normally secondary to failure of the normal closure of the umbilical ring, and which result in the protrusion of abdominal contents into the overlying subcutis. The aim of this study was to compare the suitability of commonly-used herniorrhaphies for the treatment of reducible umbilical hernia in calves. Thirty-four clinical cases presenting to the Veterinary Teaching Hospital, Chittagong Veterinary and Animal Sciences University, Chittagong, Bangladesh from July 2004 to July 2007 were subjected to comprehensive study including history, classification of hernias, size of the hernial rings, presence of adhesion with the hernial sacs, postoperative care and follow-up. They were reducible, non-painful and had no evidence of infection present on palpation. The results revealed a gender influence, with the incidence of umbilical hernia being higher in female calves than in males. Out of the 34 clinical cases, 14 were treated by open method of herniorrhaphy and 20 were treated by closed method. Complications of hernia were higher (21%) in open method-treated cases than in closed method-treated cases (5%). Hernia recurred in three calves treated with open herniorrhaphy within 2 weeks of the procedure, with swelling in situ and muscular weakness at the site of operation. Shorter operation time and excellent healing rate (80%) were found in calves treated with closed herniorrhaphy. These findings suggest that the closed herniorrhaphy is better than the commonly-used open method for the correction of reducible umbilical hernia in calves. PMID:19934601

  14. Neuroimaging evidence of brain abnormalities in mastocytosis.

    PubMed

    Boddaert, N; Salvador, A; Chandesris, M O; Lemaître, H; Grévent, D; Gauthier, C; Naggara, O; Georgin-Lavialle, S; Moura, D S; Munsch, F; Jaafari, N; Zilbovicius, M; Lortholary, O; Gaillard, R; Hermine, O

    2017-08-08

    Mastocytosis is a rare disease in which chronic symptoms are related to mast cell accumulation and activation. Patients can display depression-anxiety-like symptoms and cognitive impairment. The pathophysiology of these symptoms may be associated with tissular mast cell infiltration, mast cell mediator release or both. The objective of this study is to perform morphological or functional brain analyses in mastocytosis to identify brain changes associated with this mast cell disorder. We performed a prospective and monocentric comparative study to evaluate the link between subjective psycho-cognitive complaints, psychiatric evaluation and objective medical data using magnetic resonance imaging with morphological and perfusion sequences (arterial spin-labeled perfusion) in 39 patients with mastocytosis compared with 33 healthy controls. In the test cohort of 39 mastocytosis patients with psycho-cognitive complaints, we found that 49% of them had morphological brain abnormalities, mainly abnormal punctuated white matter abnormalities (WMA). WMA were equally frequent in cutaneous mastocytosis patients and indolent forms of systemic mastocytosis patients (42% and 41% of patients with WMA, respectively). Patients with WMA showed increased perfusion in the putamen compared with patients without WMA and with healthy controls. Putamen perfusion was also negatively correlated with depression subscores. This study demonstrates, for we believe the first time, a high prevalence of morphological and functional abnormalities in the brains of mastocytosis patients with neuropsychiatric complaints. Further studies are required to determine the mechanism underpinning this association and to ascertain its specificity.

  15. Carbetocin versus intra-umbilical oxytocin in the management of retained placenta: a randomized clinical study.

    PubMed

    Elfayomy, Amr K

    2015-08-01

    This study aimed to compare the hemodynamic profile and efficacy of carbetocin versus intra-umbilical oxytocin in the management of retained placenta following vaginal delivery. In this randomized clinical study, women with retained placenta for more than 30 min were assigned to receive either an i.v. bolus of 100-µg carbetocin (n = 38) or an intra-umbilical vein injection of 50 IU oxytocin in 30 mL saline (n = 40). The main parameters evaluated were the success rate for expulsion of the placenta and the effects of these drugs on maternal blood pressure. The success rate in the carbetocin group was 86.84% compared to 77.5% in the intra-umbilical oxytocin group. Notably, 57.7% of the participants had prior induction of labor or augmentation during labor. There were no significant differences between the two groups regarding the estimated blood loss, drop of hemoglobin within the first 48 h, additional uterotonic injection or the need for manual removal of the placenta. Systolic blood pressure was significantly lower in the intra-umbilical oxytocin group at 30 and 60 min after injection (P = 0.008, 0.026, respectively). Nonetheless, diastolic blood pressure was significantly lower in the intra-umbilical oxytocin group than in the carbetocin group at 30 min (P = 0.036). A single i.v. bolus of carbetocin and umbilical vein injection of 50 IU oxytocin are similarly effective in reducing the need for manual removal of the placenta. Carbetocin seems to have an acceptable hemodynamic safety profile and can be used as an alternative choice to the conventional oxytocic agents in the management of retained placenta. © 2015 The Authors. Journal of Obstetrics and Gynaecology Research © 2015 Japan Society of Obstetrics and Gynecology.

  16. Accuracy of chest radiography for positioning of the umbilical venous catheter.

    PubMed

    Guimarães, Adriana F M; Souza, Aline A C G de; Bouzada, Maria Cândida F; Meira, Zilda M A

    To evaluate the accuracy of the simultaneous analysis of three radiographic anatomical landmarks - diaphragm, cardiac silhouette, and vertebral bodies - in determining the position of the umbilical venous catheter distal end using echocardiography as a reference standard. This was a cross-sectional, observational study, with the prospective inclusion of data from all neonates born in a public reference hospital, between April 2012 and September 2013, submitted to umbilical venous catheter insertion as part of their medical care. The position of the catheter distal end, determined by the simultaneous analysis of three radiographic anatomical landmarks, was compared with the anatomical position obtained by echocardiography; sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated. Of the 162 newborns assessed by echocardiography, only 44 (27.16%) had the catheter in optimal position, in the thoracic portion of the inferior vena cava or at the junction of the inferior vena cava with the right atrium. The catheters were located in the left atrium and interatrial septum in 54 (33.33%) newborns, in the right atrium in 26 (16.05%), intra-hepatic in 37 (22.84%), and intra-aortic in-one newborn (0.62%). The sensitivity, specificity and accuracy of the radiography to detect the catheter in the target area were 56%, 71%, and 67.28%, respectively. Anteroposterior radiography of the chest alone is not able to safely define the umbilical venous catheter position. Echocardiography allows direct visualization of the catheter tip in relation to vascular structures and, whenever possible, should be considered to identify the location of the umbilical venous catheter. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  17. Aft Skirt Electrical Umbilical (ASEU) and Vehicle Support Post (

    NASA Image and Video Library

    2016-12-09

    A flatbed truck carries a vertical support post (VSP) for NASA's Space Launch System (SLS) rocket to the Mobile Launcher Yard at NASA's Kennedy Space Center in Florida. The two aft skirt electrical umbilicals (ASEUs) and the first of the vehicle support posts underwent a series of tests to confirm they are functioning properly and ready to support the SLS for launch. The ASEUs will connect to the SLS rocket at the bottom outer edge of each booster and provide electrical power and data connections to the rocket until it lifts off from the launch pad. The eight VSPs will support the load of the solid rocket boosters, with four posts for each of the boosters. The center’s Engineering Directorate and the Ground Systems Development and Operations Program are overseeing processing and testing of the umbilicals.

  18. Aft Skirt Electrical Umbilical (ASEU) and Vehicle Support Post (

    NASA Image and Video Library

    2016-12-09

    A flatbed truck carries a vertical support post (VSP) for NASA's Space Launch System (SLS) rocket to the Mobile Launcher Yard at NASA's Kennedy Space Center in Florida. In view is the mobile launcher. The two aft skirt electrical umbilicals (ASEUs) and the first of the vehicle support posts underwent a series of tests to confirm they are functioning properly and ready to support the SLS for launch. The ASEUs will connect to the SLS rocket at the bottom outer edge of each booster and provide electrical power and data connections to the rocket until it lifts off from the launch pad. The eight VSPs will support the load of the solid rocket boosters, with four posts for each of the boosters. The center’s Engineering Directorate and the Ground Systems Development and Operations Program are overseeing processing and testing of the umbilicals.

  19. Neonatal Cardio-pulmonary Arrest: Emergency Catheterization of Umbilical Vein

    PubMed Central

    Paes, Bosco A.; Blatz, Susan; Kraftcheck, D.J.

    1990-01-01

    In an emergency, the physician responsible for neonatal care must be skilled in umbilical catheterization. Several drugs can be given through an endotracheal tube, but some require intravenous administration. The umbilical vein is a better route of administration than peripheral veins because it is easily located and can be entered readily. It allows immediate access to the central circulation, enhancing drug distribution. The authors outline the procedure in a step-by-step description. This pictorial article can be used as a handy reference by physicians needing to administer fluids and drugs during cardio-pulmonary arrest in neonates. Imagesp1136-ap1136-bp1136-cp1136-dp1137-ap1137-bp1137-cp1137-dp1137-ep1138-ap1138-bp1138-cp1138-dp1139-ap1139-bp1139-cp1139-dp1140-ap1140-bp1140-cp1140-d PMID:21233982

  20. Laparoscopic surgical treatment of umbilical hernia and small eventrations with prosthetic mesh using omentum overlay.

    PubMed

    Bratu, D; Sabău, A; Dumitra, A; Sabău, D; Miheţiu, A; Beli, L; Hulpuş, R

    2014-01-01

    Umbilical hernias and abdominal incisional hernias represent current pathologies which require numerous surgical alternative ways of treatment in prosthetic or non prosthetic,open or minimally invasive surgery. The method proposed by us is a less expensive option with no additional risks compared to other similar procedures as surgical technique. We conducted a retrospective study between 01.01.2008 - 01.06.2013 in which we considered a number of 23 patients with umbilical hernia and eventration, patients who received laparoscopic intraperitoneal polyester mesh covered with omentum, procedure applied at the IInd Surgery Clinic, Clinical County Emergency Hospital Sibiu. Out of 23 patients with postoperative umbilical hernia and eventration cases in which we used this surgical technique,16 were umbilical hernias and 7 post incisional hernias. The average time of surgery was 1 hour and 40 minutes, recording 4 postoperative complications remitted under conservative treatment, with a mean hospitalization of 4.1 days. Proepiploic laparoscopic treatment using omentum is a reliable alternative to a more expensive and difficult procedure involving Dual Mesh. Celsius.

  1. Neonatal testicular infarction--possibly due to compression of the umbilical cord?

    PubMed

    Eifinger, Frank; Ahrens, Ulrike; Wille, Sebastian; Roth, Bernhard; Engelmann, Udo

    2010-06-01

    Neonatal testicular infarction is a rare occurrence. We report on a newborn infant with bilateral testicular infarction. At birth, the uncut umbilical cord ran taut between the thighs making a complete loop around the genitals, compressing the testes. At the age of 6 hours, because of increasing agitation and the beginnings of scrotal discoloration, the infant was operated on, showing a bilateral testicular infarction potentially induced by strangulation of the twisted umbilical cord. Here, we discuss the clinical findings of neonatal testicular infarction and give advice as to the management of this serious complication with regard to the available published data. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  2. Spontaneous Rupture of Umbilical Hernia in Pregnancy: A Case Report

    PubMed Central

    Ahmed, Adamu; Stephen, Garba; Ukwenya, Yahaya

    2011-01-01

    A 28 year old woman presented with a spontaneous rupture of an umbilical hernia in her seventh month of pregnancy. She had four previous unsupervised normal deliveries. There was no history of trauma or application of herbal medicine on the hernia. The hernia sac ruptured at the inferior surface where it was attached to the ulcerated and damaged overlying skin. There was a gangrenous eviscerated small bowel. The patient was resuscitated and the gangrenous small bowel was resected and end to end anastomosis done. The hernia sac was excised and the 12 cm defect repaired. Six weeks later, she had spontaneous vaginal delivery of a live baby. We advocate that large umbilical hernias should be routinely repaired when seen in women of child bearing age. PMID:22043438

  3. A new approach to umbilical hernia repair: the circular suture technique for defects less than 2 cm.

    PubMed

    Yıldız, Ihsan; Koca, Yavuz Savas

    2017-01-01

    Umbilical hernia, unlike other abdominal wall hernias, occurs when the umbilical ring opens and expands. Its' symptoms and complications show similarities with other hernias. Although there are various repair techniques, there is not a standard technique yet. This paper investigated the outcomes of double layer circular suture technique as a new approach in the repair of umbilical hernia. A total number of 282 patients comprised of 102 males and 180 females with an age range of 18-89 whose umbilical hernias were repaired between 2002 and 2013, retrospectively studied in two groups group 1 (circular suture technique) and group 2 (open primary suture). The subjects were investigated with regards to age, sex, body mass index (BMI), accompanying disease, anesthesia method, surgical complications, hospital stay, total costs, mortality and recurrence. The study participants were 282 patients with an age average of 49, 09 ± 16, 62 including 182 patients in group 1 (male/female ratio 76/106) and 100 patients in group 2 (26/74). There was a significant difference between the groups in terms of time and recurrence. During the follow-up period, 9 patients in group 1 (4.94%) and 16 patients in group 2 (16%) had a recurrence. This result was statistically significant (p=0.014) CONCLUSION: We believe that the double layer circular suture technique is practical, inexpensive and effective in the repair of umbilical hernia defects, which are smaller than 2 cm diameter. Key words: Hernia, Repair, Umbilical hernia.

  4. Abnormal placental invasion--a novel approach to treatment case report and review.

    PubMed

    Ophir, Ella; Singer-Jordan, Jonathan; Odeh, Marwan; Hirch, Yael; Maksimovsky, Olga; Shaider, Oleg; Yvry, Simon; Solt, Ido; Bornstein, Jacob

    2009-12-01

    The incidence of abnormal placental invasion has increased 10-fold in the past 50 years, reflecting the increased number of cesarean sections performed. Management relies on accurate early diagnosis with appropriate perioperative multidisciplinary planning to anticipate and avoid massive obstetric hemorrhage at delivery. Women at risk should plan to deliver at an institution with appropriate expertise and resources for managing this condition. We report a case of placenta increta management comprising preoperative placement of a pelvic artery balloon catheter, prophylactic balloon occlusion after delivery of the fetus, and embolization-assisted resection of the invaded uterine wall. We review incidence, methods of prenatal diagnosis, risk factors, and management of abnormally invasive placenta.

  5. Morning glory disk anomaly with ipsilateral capillary hemangioma, agenesis of the internal carotid artery, and Horner syndrome: a variant of PHACES syndrome?

    PubMed

    Puvanachandra, Narman; Heran, Manraj K; Lyons, Christopher J

    2008-10-01

    We describe a 6-week-old girl with a right upper lid capillary hemangioma, ipsilateral morning glory disk anomaly, microphthalmos, Mittendorf dot, and Horner syndrome. The ipsilateral internal carotid artery was also found to be absent. To our knowledge, this is the first patient to be reported with this group of findings. We suggest that this represents an overlap between morning glory disk and intracranial vascular abnormalities, a recognized association, and PHACES syndrome (posterior fossa malformations, hemangiomas, arterial anomalies, cardiac defects, eye, and sternal abnormalities). We discuss the common embryological basis for these abnormalities, which point to a widespread but highly variable disorder of mesodermal differentiation.

  6. Shielded, Automated Umbilical Mechanism

    NASA Technical Reports Server (NTRS)

    Barron, Daniel R.; Morrill, Brion F.; Jasulaitis, Vytas

    1995-01-01

    Umbilical mechanism automatically connects and disconnects various fluid couplings and/or electrical contacts while shielding mating parts from debris. Reacts mating and demating loads internally, without additional supporting structures. All functions - extension of plug, mating, and movement of debris shields - actuated by single motor. If mechanism jams or fails at any point in sequence, override feature in drive train allows manual operation. Designed for service in outer space, where its shields protect against micrometeoroids, debris, ultraviolet radiation, and atomic oxygen. Used on Earth to connect or disconnect fluid or electrical utilities in harsh environments like those of nuclear powerplants or undersea construction sites, or in presence of radioactive, chemical, or biological hazards, for example.

  7. Evaluation of third trimester uterine artery flow velocity indices in relationship to perinatal complications.

    PubMed

    Ghosh, G; Breborowicz, A; Brazert, M; Maczkiewicz, M; Kobelski, M; Dubiel, M; Gudmundsson, S

    2006-09-01

    Uterine artery Doppler is becoming a routine part of pregnancy surveillance in high-risk pregnancies. Which blood flow velocity waveform index to measure is debated and the 'notch' in early diastole is not widely accepted, as it is a subjective measure. The aim of the present study was to evaluate the different indices in the prediction of adverse outcome of pregnancies suspected for intrauterine fetal growth restriction (IUGR). Uterine artery blood flow was recorded in 217 pregnancies admitted for Doppler ultrasound surveillance due to suspected IUGR. The median gestational age at examination was 38 weeks (range 25-42 weeks). Only cases having bilateral uterine artery notching were included in the evaluation. The uterine artery Doppler spectrum was analyzed for different indices, including evaluation of notch and end-diastolic velocities. Umbilical artery Doppler velocimetry was also performed. The outcome variables chosen were: a small-for-gestational-age (SGA) newborn, preterm birth, and abdominal delivery. ROC-curve calculations were used to compare the different indices. The uterine artery blood velocity pulsatility index (PI) and resistance indices (RI) were the best predictors of adverse outcome of pregnancy. Apart from premature birth, the systolic/end-diastolic ratio was less predictive of adverse outcome. The indices including only diastolic blood velocities were the least predictive of adverse outcome. The group with notch velocity above end-diastolic velocity was compared with those having notch velocity below the end-diastolic velocity. No difference in outcome was seen between the two groups. RI and PI as measures of third trimester utero-placental vascular impedance are the best predictors of adverse outcome of IUGR-suspected pregnancies.

  8. Ventilation/Perfusion distribution abnormalities in morbidly obese subjects before and after bariatric surgery.

    PubMed

    Rivas, Eva; Arismendi, Ebymar; Agustí, Alvar; Sanchez, Marcelo; Delgado, Salvadora; Gistau, Concepción; Wagner, Peter D; Rodriguez-Roisin, Roberto

    2015-04-01

    Obesity is a global and growing public health problem. Bariatric surgery (BS) is indicated in patients with morbid obesity. To our knowledge, the effects of morbid obesity and BS on ventilation/perfusion (V.a/Q.) ratio distributions using the multiple inert gas elimination technique have never before been explored. We compared respiratory and inert gas (V.a/Q. ratio distributions) pulmonary gas exchange, breathing both ambient air and 100% oxygen, in 19 morbidly obese women (BMI, 45 kg/m2), both before and 1 year after BS, and in eight normal-weight, never smoker, age-matched, healthy women. Before BS, morbidly obese individuals had reduced arterial Po2 (76 ± 2 mm Hg) and an increased alveolar-arterial Po2 difference (27 ± 2 mm Hg) caused by small amounts of shunt (4.3% ± 1.1% of cardiac output), along with abnormally broadly unimodal blood flow dispersion (0.83 ± 0.06). During 100% oxygen breathing, shunt increased twofold in parallel with a reduction of blood flow to low V.a/Q. units, suggesting the development of reabsorption atelectasis without reversion of hypoxic pulmonary vasoconstriction. After BS, body weight was reduced significantly (BMI, 31 kg/m2), and pulmonary gas exchange abnormalities were decreased. Morbid obesity is associated with mild to moderate shunt and V.a/Q. imbalance. These abnormalities are reduced after BS.

  9. Interdependence of arterial PO2 and O2 consumption in the fetal sheep.

    PubMed

    Asakura, H; Ball, K T; Power, G G

    1990-04-01

    These experiments were undertaken to measure the effects of changing arterial oxygen tension (PaO2) on oxygen use by the fetal body (VO2). Six fetal sheep at 130-140 days gestation were prepared with an endotracheal tube, carotid artery catheter, body-core thermistor, cooling coil and loosely-applied umbilical cord snare. The next day the cord was occluded and the fetal lungs were ventilated with gas mixtures containing different concentrations of oxygen. While fetal core temperature was kept constant, fetal arterial PO2 was cycled between high and low values (span = 7 to 359 mmHg, n = 103) and O2 consumption was measured by the rate of O2 uptake from a closed-rebreathing circuit. VO2 changed directly with changes in PO2 from 10 to 40 mmHg but became insensitive to changes in PO2 above about 50 mmHg. The results were well described over the entire range by the equation: VO2 (ml/min per kg fetal wt) = -9.62 + 6.99 ln PO2(mmHg)-0.66 ln2 PO2. Thus the oxygen consumption of the near-term fetal sheep varies with changes in arterial PO2 in the physiologic range. This finding is distinctly different than the adult at rest but resembles adult tissues such as exercising muscle at VO2max. This finding is consistent with differences in fetal metabolic controls, limited cardiac reserve, and limited tissue diffusion rates in actively metabolizing tissues.

  10. Applications of human umbilical cord blood cells in central nervous system regeneration.

    PubMed

    Herranz, Antonio S; Gonzalo-Gobernado, Rafael; Reimers, Diana; Asensio, Maria J; Rodríguez-Serrano, Macarena; Bazán, Eulalia

    2010-03-01

    In recent decades, there has been considerable amount of information about embryonic stem cells (ES). The dilemma facing scientists interested in the development and use of human stem cells in replacement therapies is the source of these cells, i.e. the human embryo. There are many ethical and moral problems related to the use of these cells. Hematopoietic stem cells from umbilical cord blood have been proposed as an alternative source of embryonic stem cells. After exposure to different agents, these cells are able to express antigens of diverse cellular lineages, including the neural type. The In vitro manipulation of human umbilical cord blood (hUCB) cells has shown their stem capacity and plasticity. These cells are easily accessible, In vitro amplifiable, well tolerated by the host, and with more primitive molecular characteristics that give them great flexibility. Overall, these properties open a promising future for the use of hUCB in regenerative therapies for the Central Nervous System (CNS). This review will focus on the available literature concerning umbilical cord blood cells as a therapeutic tool for the treatment of neurodegenerative diseases.

  11. Correlation of Arterial Stiffness With Left Atrial Volume Index and Left Ventricular Mass Index in Young Adults: Evaluation by Coronary Computed Tomography Angiography.

    PubMed

    Osawa, Kazuhiro; Nakanishi, Rine; Miyoshi, Toru; Rahmani, Sina; Ceponiene, Indre; Nezarat, Negin; Kanisawa, Mitsuru; Qi, Hong; Jayawardena, Eranthi; Kim, Nicholas; Ito, Hiroshi; Budoff, Matthew J

    2018-04-26

    Increased arterial stiffness is reportedly associated with cardiac remodelling, including the left atrium and left ventricle, in middle-aged and older adults. However, little is known about this association in young adults. In total, 73 patients (44 (60%) men) aged 25 to 45 years with suspected coronary artery disease were included in the analysis. The left atrial volume index (LAVI), left ventricular volume index (LVVI), and left ventricular mass index (LVMI) were measured using coronary computed tomography angiography (CCTA). Arterial stiffness was assessed with the cardio-ankle vascular index (CAVI). An abnormally high CAVI was defined as that above the age- and sex-specific cut-off points of the CAVI. Compared with patients with a normal CAVI, those with an abnormally high CAVI were older and had a greater prevalence of diabetes mellitus, higher diastolic blood pressure, greater coronary artery calcification score, and a greater LAVI (33.5±10.3 vs. 43.0±10.3mL/m 2 , p <0.01). In contrast, there were no significant differences in the LVVI or LVMI between the subgroups with a normal CAVI and an abnormally high CAVI. Multivariate linear regression analysis showed that the LAVI was significantly associated with an abnormally high CAVI (standardised regression coefficient=0.283, p=0.03). The present study demonstrated that increased arterial stiffness is associated with the LAVI, which reflects the early stages of cardiac remodelling, independent of various comorbidity factors in young adults with suspected coronary artery disease. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  12. Renal artery anatomy affects the blood pressure response to renal denervation in patients with resistant hypertension.

    PubMed

    Hering, Dagmara; Marusic, Petra; Walton, Antony S; Duval, Jacqueline; Lee, Rebecca; Sata, Yusuke; Krum, Henry; Lambert, Elisabeth; Peter, Karlheinz; Head, Geoff; Lambert, Gavin; Esler, Murray D; Schlaich, Markus P

    2016-01-01

    Renal denervation (RDN) has been shown to reduce blood pressure (BP), muscle sympathetic nerve activity (MSNA) and target organ damage in patients with resistant hypertension (RH) and bilateral single renal arteries. The safety and efficacy of RDN in patients with multiple renal arteries remains unclear. We measured office and 24-hour BP at baseline, 3 and 6 months following RDN in 91 patients with RH, including 65 patients with single renal arteries bilaterally (group 1), 16 patients with dual renal arteries on either one or both sides (group 2) and 10 patients with other anatomical constellations or structural abnormalities (group 3). Thirty nine out of 91 patients completed MSNA at baseline and follow-up. RDN significantly reduced office and daytime SBP in group 1 at both 3 and 6 months follow-up (P<0.001) but not in groups 2 and 3. Similarly, a significant reduction in resting baseline MSNA was only observed in group 1 (P<0.05). There was no deterioration in kidney function in any group. While RDN can be performed safely irrespective of the underlying renal anatomy, the presence of single renal arteries with or without structural abnormalities is associated with a more pronounced BP and MSNA lowering effect than the presence of dual renal arteries in patients with RH. However, when patients with dual renal arteries received renal nerve ablation in all arteries there was trend towards a greater BP reduction. Insufficient renal sympathetic nerve ablation may account for these differences. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  13. Umbilical cord vitamin D, ionized calcium and myocardial oxygen demand.

    PubMed

    Reeves, Inez; Liang, Willie; Asadi, M Sadegh; Millis, Richard M

    2014-07-01

    Systemic blood vitamin D and total calcium are correlates of birthweight and cardiovascular disease but whether umbilical cord blood vitamin D and ionized calcium are correlates of birthweight and cardiovascular function is not known. This cross-sectional study correlates umbilical cord vitamin D, ionized calcium and birthweight with the heart rate-systolic pressure product (RPP), an indicator of myocardial oxygen demand. Cord blood vitamin D and ionized calcium concentrations were compared for vitamin D normal (≥50 nM, 20 ng/mL) and vitamin D deficiency (<50 nM, 20 ng/mL) in normal weight (≥2500 g) and low birthweight (LBW, <2500 g) newborns. Heart rate and blood pressure were measured during postnatal transition and RPP was computed. RPP was positively correlated with birthweight (r = +0.52, p < 0.001) and with cord ionized calcium level (r = +0.42, p < 0.01) in the normal and LBW newborns. RPP was positively correlated with cord vitamin D level in the LBW newborns (raw r = +0.50, p < 0.05, normalized for birthweight r = +0.73, p < 0.01). Small RPP, an indicator of low myocardial oxygen demand, in LBW newborns appears to correlate with low umbilical cord vitamin D and ionized calcium levels, suggestive of pathological heart development.

  14. The Hernia-Neck-Ratio (HNR), a Novel Predictive Factor for Complications of Umbilical Hernia.

    PubMed

    Fueter, T; Schäfer, M; Fournier, P; Bize, P; Demartines, N; Allemann, P

    2016-09-01

    Umbilical hernia is a common pathology and surgical repair is advised to prevent complications in symptomatic patients. However, risk factors that predict such advert events are unknown. The aim of the study was to determine whether morphological characteristics are associated with the occurrence of complications. Retrospective review of adult patients with elective and emergent umbilical hernia repair operated from January 2004 to December 2013. The size of the hernia and the size of the neck were measured based on operative reports, ultrasound, CT or MRI images. The Hernia-Neck-Ratio (HNR) was then calculated as novel risk indicator. 106 patients underwent umbilical hernia repair (70 for uncomplicated and 36 for complicated hernia) as single procedure. The median size of the hernia sac was statistically significantly smaller in the uncomplicated group (30 mm, interquartile range (IQR) 20-49 vs. 50 mm, IQR 40-71, p = 0.037). The median size of the neck was not different between both groups (15 mm, IQR 11-29 vs. 16 mm, IQR 12-21, p = 0.44). The median HNR was smaller in the uncomplicated group (1.76, IQR 1.45-2.18 vs. 3.33, IQR 2.97-3.91, p = 0.00026). Based on ROC curve analysis (area under the curve: 0.9038), a cut-off value of 2.5 was associated with 91 % sensitivity and 84 % specificity. A novel predictive factor for complications related to umbilical hernia is proposed. The Hernia-Neck Ratio can easily be calculated. These results suggest that umbilical hernia with HNR >2.5 should be operated, irrespective of the presence of symptoms.

  15. Combination of serum angiopoietin-2 and uterine artery Doppler for prediction of preeclampsia.

    PubMed

    Puttapitakpong, Ploynin; Phupong, Vorapong

    2016-02-01

    The aim of this study was to determine the predictive value of the combination of serum angiopoietin-2 (Ang-2) levels and uterine artery Doppler for the detection of preeclampsia in women at 16-18 weeks of gestation and to identify other pregnancy complications that could be predicted with these combined tests. Maternal serum Ang-2 levels were measured, and uterine artery Doppler was performed in 400 pregnant women. The main outcome was preeclampsia. The predictive values of this combination were calculated. Twenty-five women (6.3%) developed preeclampsia. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of uterine artery Doppler combined with serum Ang-2 levels for the prediction of preeclampsia were 24.0%, 94.4%, 22.2% and 94.9%, respectively. For the prediction of early-onset preeclampsia, the sensitivity, specificity, PPV and NPV were 57.1%, 94.1%, 14.8% and 99.2%, respectively. Patients with abnormal uterine artery Doppler and abnormal serum Ang-2 levels (above 19.5 ng ml(-1)) were at higher risk for preterm delivery (relative risk=2.7, 95% confidence interval 1.2-5.8). Our findings revealed that the combination of uterine artery Doppler and serum Ang-2 levels at 16-18 weeks of gestation can be used to predict early-onset preeclampsia but not overall preeclampsia. Thus, this combination may be a useful early second trimester screening test for the prediction of early-onset preeclampsia.

  16. Aft Skirt Electrical Umbilical (ASEU) and Vehicle Support Post (

    NASA Image and Video Library

    2016-12-09

    A construction worker is in view as a flatbed truck passes by carrying a vertical support post (VSP) for NASA's Space Launch System (SLS) rocket to the Mobile Launcher Yard at NASA's Kennedy Space Center in Florida. The two aft skirt electrical umbilicals (ASEUs) and the first of the vehicle support posts underwent a series of tests to confirm they are functioning properly and ready to support the SLS for launch. The ASEUs will connect to the SLS rocket at the bottom outer edge of each booster and provide electrical power and data connections to the rocket until it lifts off from the launch pad. The eight VSPs will support the load of the solid rocket boosters, with four posts for each of the boosters. The center’s Engineering Directorate and the Ground Systems Development and Operations Program are overseeing processing and testing of the umbilicals.

  17. A "Kane's Dynamics" Model for the Active Rack Isolation System. Part 3; Addition of Umbilicals to the Nonlinear Model

    NASA Technical Reports Server (NTRS)

    Rupert, J. K.; Hampton, R. D.; Beech, G. S.

    2005-01-01

    In the late 1980s, microgravity researchers began to voice their concern that umbilical-transmitted energy could significantly degrade the acceleration environment of microgravity space science experiments onboard manned spacecraft. Since umbilicals are necessary for many experiments, control designers began to seek ways to compensate for these "indirect" disturbances. Hampton, et al., used the Kane s method to develop a model of the active rack isolation system (ARIS) that includes (1) actuator control forces, (2) direct disturbance forces, and (3) indirect, actuator-transmitted disturbances. Their model does not, however, include the indirect, umbilical-transmitted disturbances. Since the umbilical stiffnesses are not negligible, these indirect disturbances must be included in the model. Until the umbilicals have been appropriately included, the model will be incomplete. This Technical Memorandum presents a nonlinear model of ARIS with umbilicals included. Model verification was achieved by utilizing two commercial-off-the-shelf software tools. Various forces and moments were applied to the model to yield simulated responses of the system. Plots of the simulation results show how various critical points on an ARIS-outfitted international standard payload rack behave under the application of direct disturbances, indirect disturbances, and control forces. Simulations also show system response to a variety of initial conditions.

  18. Correlation-based perfusion mapping using time-resolved MR angiography: A feasibility study for patients with suspicions of steno-occlusive craniocervical arteries.

    PubMed

    Nam, Yoonho; Jang, Jinhee; Park, Sonya Youngju; Choi, Hyun Seok; Jung, So-Lyung; Ahn, Kook-Jin; Kim, Bum-Soo

    2018-05-22

    To explore the feasibility of using correlation-based time-delay (CTD) maps produced from time-resolved MR angiography (TRMRA) to diagnose perfusion abnormalities in patients suspected to have steno-occlusive lesions in the craniocervical arteries. Twenty-seven patients who were suspected to have steno-occlusive lesions in the craniocervical arteries underwent both TRMRA and brain single-photon emission computed tomography (SPECT). TRMRA was performed on the supra-aortic area after intravenous injection of a 0.03 mmol/kg gadolinium-based contrast agent. Time-to-peak (TTP) maps and CTD maps of the brain were automatically generated from TRMRA data, and their quality was assessed. Detection of perfusion abnormalities was compared between CTD maps and the time-series maximal intensity projection (MIP) images from TRMRA and TTP maps. Correlation coefficients between quantitative changes in SPECT and parametric maps for the abnormal perfusion areas were calculated. The CTD maps were of significantly superior quality than TTP maps (p < 0.01). For perfusion abnormality detection, CTD maps (kappa 0.84, 95% confidence interval [CI] 0.67-1.00) showed better agreement with SPECT than TTP maps (0.66, 0.46-0.85). For perfusion deficit detection, CTD maps showed higher accuracy (85.2%, 95% CI 66.3-95.8) than MIP images (66.7%, 46-83.5), with marginal significance (p = 0.07). In abnormal perfusion areas, correlation coefficients between SPECT and CTD (r = 0.74, 95% CI 0.34-0.91) were higher than those between SPECT and TTP (r = 0.66, 0.20-0.88). CTD maps generated from TRMRA were of high quality and offered good diagnostic performance for detecting perfusion abnormalities associated with steno-occlusive arterial lesions in the craniocervical area. • Generation of perfusion parametric maps from time-resolved MR angiography is clinically useful. • Correlation-based delay maps can be used to detect perfusion abnormalities associated with steno-occlusive craniocervical arteries

  19. Prediction of vascular abnormalities on CT angiography in patients with acute headache.

    PubMed

    Alons, Imanda M E; Goudsmit, Ben F J; Jellema, Korné; van Walderveen, Marianne A A; Wermer, Marieke J H; Algra, Ale

    2018-05-09

    Patients with acute headache increasingly undergo CT-angiography (CTA) to evaluate underlying vascular causes. The aim of this study is to determine clinical and non-contrast CT (NCCT) criteria to select patients who might benefit from CTA. We retrospectively included patients with acute headache who presented to the emergency department of an academic medical center and large regional teaching hospital and underwent NCCT and CTA. We identified factors that increased the probability of finding a vascular abnormality on CTA, performed multivariable regression analyses and determined discrimination with the c-statistic. A total of 384 patients underwent NCCT and CTA due to acute headache. NCCT was abnormal in 194 patients. Among these, we found abnormalities in 116 cases of which 99 aneurysms. In the remaining 190 with normal NCCT we found abnormalities in 12 cases; four unruptured aneurysms, three cerebral venous thrombosis', two reversible cerebral vasoconstriction syndromes, two cervical arterial dissections and one cerebellar infarction. In multivariable analysis abnormal NCCT, lowered consciousness and presentation within 6 hr of headache onset were independently associated with abnormal CTA. The c-statistic of abnormal NCCT alone was 0.80 (95% CI: 0.75-0.80), that also including the other two variables was 0.84 (95% CI: 0.80-0.88). If NCCT was normal no other factors could help identify patients at risk for abnormalities. In patients with acute headache abnormal NCCT is the strongest predictor of a vascular abnormality on CTA. If NCCT is normal no other predictors increase the probability of finding an abnormality on CTA and diagnostic yield is low. © 2018 The Authors. Brain and Behavior published by Wiley Periodicals, Inc.

  20. Segmental arterial mediolysis--an iatrogenic vascular disorder induced by ractopamine.

    PubMed

    Slavin, Richard E; Yaeger, Micheal J

    2012-01-01

    Segmental arterial mediolysis, an uncommon arterial disorder most often occurring in the splanchnic muscular arteries of the abdomen, is a cause of catastrophic hemorrhages. Its histology and initial clinical presentations suggested that it represented a localized norepinephrine-induced vasospastic response to perturbations in vascular tone and blood volume distribution caused by coexisting vasoconstrictor conditions. However, later presentations were at odds with some aspects of this hypothesis. Nine greyhound dogs were administered a single dose of ractopamine. Two dogs developing persistent conduction abnormalities with biochemical evidence of heart injury were euthanized and necropsied--one 4 days and the other 17 days after dosage This report is based on findings and comparisons of the canine abdominal and coronary arteries to segmental arterial mediolysis. Lesions having features of early-injurious-stage segmental arterial mediolysis were identified in the canine arteries 4 days postractopamine, and arteries examined after 17 days showed alterations typically occurring in reparative-stage segmental arterial mediolysis. It is suspected that ractopamine, a Beta-2 adrenergic agonist, created segmental arterial mediolysis by neuromodulating the peripheral sympathetic nervous system to release norepinephrine from varicosities of efferent nerves serving splanchnic arteries that stimulate alpha-1 receptors to induce injury at the adventitial medial junction and medial muscle apoptosis. This finding and other cited examples suggest that segmental arterial mediolysis may be a disorder principally caused by iatrogenic or accidental exposure to alpha-1 adrenergic receptor agonists or Beta-2 agonists able to release norepinephrine from the peripheral nervous system. Copyright © 2012 Elsevier Inc. All rights reserved.