Sample records for absorvidas por auto-irradiacao

  1. Myocarditis in auto-immune or auto-inflammatory diseases.

    PubMed

    Comarmond, Cloé; Cacoub, Patrice

    2017-08-01

    Myocarditis is a major cause of heart disease in young patients and a common precursor of heart failure due to dilated cardiomyopathy. Some auto-immune and/or auto-inflammatory diseases may be accompanied by myocarditis, such as sarcoidosis, Behçet's disease, eosinophilic granulomatosis with polyangiitis, myositis, and systemic lupus erythematosus. However, data concerning myocarditis in such auto-immune and/or auto-inflammatory diseases are sparse. New therapeutic strategies should better target the modulation of the immune system, depending on the phase of the disease and the type of underlying auto-immune and/or auto-inflammatory disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Automotive Mechanics as Applied to Auto Body; Auto Body Repair and Refinishing 3: 9037.02.

    ERIC Educational Resources Information Center

    Dade County Public Schools, Miami, FL.

    This is a course in which the student will receive the general information, technical knowledge, basic skills, attitudes, and values required for job entry level as an auto body repair helper. Course content includes general and specific goals, orientation, instruction in service tools and bench skills, and auto mechanics as applied to auto body.…

  3. Auto-immune hepatitis following delivery.

    PubMed

    Saini, Vandana; Gupta, Mamta; Mishra, S K

    2013-05-01

    Auto-immune hepatitis first presenting in the early postpartum period is rare. Immunosuppressive effects of pregnancy result in delayed manifestation of auto-immune hepatitis, and in established cases, the spontaneous improvements are there. Auto-immune hepatitis should be considered in the differential diagnosis of liver dysfunction first presenting in the early postpartum period. A case of postpartum hepatitis of auto-immune aetiology is being presented here. It is disease of unknown aetiology, characterised by inflammation of liver (as evidenced by raised serum transaminases, presence of interface hepatitis on histological examination), hypergammaglobulinaemia (> 1.5 times normal), presence of auto-antibodies [(antinuclear antibodies (ANA)], smooth muscle antibody (SMA) and antibody to liver-kidney microsome type 1 (LKM1) in the absence of viral markers ie, hepatitis B (HBsAg) and C (AntiHCV) and excellent response to corticosteroid therapy.

  4. AutoGen Version 5.0

    NASA Technical Reports Server (NTRS)

    Gladden, Roy E.; Khanampornpan, Teerapat; Fisher, Forest W.

    2010-01-01

    Version 5.0 of the AutoGen software has been released. Previous versions, variously denoted Autogen and autogen, were reported in two articles: Automated Sequence Generation Process and Software (NPO-30746), Software Tech Briefs (Special Supplement to NASA Tech Briefs), September 2007, page 30, and Autogen Version 2.0 (NPO- 41501), NASA Tech Briefs, Vol. 31, No. 10 (October 2007), page 58. To recapitulate: AutoGen (now signifying automatic sequence generation ) automates the generation of sequences of commands in a standard format for uplink to spacecraft. AutoGen requires fewer workers than are needed for older manual sequence-generation processes, and greatly reduces sequence-generation times. The sequences are embodied in spacecraft activity sequence files (SASFs). AutoGen automates generation of SASFs by use of another previously reported program called APGEN. AutoGen encodes knowledge of different mission phases and of how the resultant commands must differ among the phases. AutoGen also provides means for customizing sequences through use of configuration files. The approach followed in developing AutoGen has involved encoding the behaviors of a system into a model and encoding algorithms for context-sensitive customizations of the modeled behaviors. This version of AutoGen addressed the MRO (Mars Reconnaissance Orbiter) primary science phase (PSP) mission phase. On previous Mars missions this phase has more commonly been referred to as mapping phase. This version addressed the unique aspects of sequencing orbital operations and specifically the mission specific adaptation of orbital operations for MRO. This version also includes capabilities for MRO s role in Mars relay support for UHF relay communications with the MER rovers and the Phoenix lander.

  5. Criterion-Referenced Test Items for Auto Body.

    ERIC Educational Resources Information Center

    Tannehill, Dana, Ed.

    This test item bank on auto body repair contains criterion-referenced test questions based upon competencies found in the Missouri Auto Body Competency Profile. Some test items are keyed for multiple competencies. The tests cover the following 26 competency areas in the auto body curriculum: auto body careers; measuring and mixing; tools and…

  6. Assessment of Factors Related to Auto-PEEP.

    PubMed

    Natalini, Giuseppe; Tuzzo, Daniele; Rosano, Antonio; Testa, Marco; Grazioli, Michele; Pennestrì, Vincenzo; Amodeo, Guido; Marsilia, Paolo F; Tinnirello, Andrea; Berruto, Francesco; Fiorillo, Marialinda; Filippini, Matteo; Peratoner, Alberto; Minelli, Cosetta; Bernardini, Achille

    2016-02-01

    Previous physiological studies have identified factors that are involved in auto-PEEP generation. In our study, we examined how much auto-PEEP is generated from factors that are involved in its development. One hundred eighty-six subjects undergoing controlled mechanical ventilation with persistent expiratory flow at the beginning of each inspiration were enrolled in the study. Volume-controlled continuous mandatory ventilation with PEEP of 0 cm H2O was applied while maintaining the ventilator setting as chosen by the attending physician. End-expiratory and end-inspiratory airway occlusion maneuvers were performed to calculate respiratory mechanics, and tidal flow limitation was assessed by a maneuver of manual compression of the abdomen. The variable with the strongest effect on auto-PEEP was flow limitation, which was associated with an increase of 2.4 cm H2O in auto-PEEP values. Moreover, auto-PEEP values were directly related to resistance of the respiratory system and body mass index and inversely related to expiratory time/time constant. Variables that were associated with the breathing pattern (tidal volume, frequency minute ventilation, and expiratory time) did not show any relationship with auto-PEEP values. The risk of auto-PEEP ≥5 cm H2O was increased by flow limitation (adjusted odds ratio 17; 95% CI: 6-56.2), expiratory time/time constant ratio <1.85 (12.6; 4.7-39.6), respiratory system resistance >15 cm H2O/L s (3; 1.3-6.9), age >65 y (2.8; 1.2-6.5), and body mass index >26 kg/m(2) (2.6; 1.1-6.1). Flow limitation, expiratory time/time constant, resistance of the respiratory system, and obesity are the most important variables that affect auto-PEEP values. Frequency expiratory time, tidal volume, and minute ventilation were not independently associated with auto-PEEP. Therapeutic strategies aimed at reducing auto-PEEP and its adverse effects should be primarily oriented to the variables that mainly affect auto-PEEP values. Copyright © 2016 by

  7. Spot auto-focusing and spot auto-stigmation methods with high-definition auto-correlation function in high-resolution TEM.

    PubMed

    Isakozawa, Shigeto; Fuse, Taishi; Amano, Junpei; Baba, Norio

    2018-04-01

    As alternatives to the diffractogram-based method in high-resolution transmission electron microscopy, a spot auto-focusing (AF) method and a spot auto-stigmation (AS) method are presented with a unique high-definition auto-correlation function (HD-ACF). The HD-ACF clearly resolves the ACF central peak region in small amorphous-thin-film images, reflecting the phase contrast transfer function. At a 300-k magnification for a 120-kV transmission electron microscope, the smallest areas used are 64 × 64 pixels (~3 nm2) for the AF and 256 × 256 pixels for the AS. A useful advantage of these methods is that the AF function has an allowable accuracy even for a low s/n (~1.0) image. A reference database on the defocus dependency of the HD-ACF by the pre-acquisition of through-focus amorphous-thin-film images must be prepared to use these methods. This can be very beneficial because the specimens are not limited to approximations of weak phase objects but can be extended to objects outside such approximations.

  8. V-TECS Guide for Auto Body Repair.

    ERIC Educational Resources Information Center

    Gregory, Margaret R.; Benson, Robert T.

    This curriculum guide consists of materials for teaching a course in auto body repair. Addressed in the individual units of the guide are the following topics: the nature and scope of auto body repair; safety; tools; auto body construction; simple metal straightening; welding; painting and refinishing; refinishing complete lacquer; refinishing…

  9. Conversations with AutoTutor Help Students Learn

    ERIC Educational Resources Information Center

    Graesser, Arthur C.

    2016-01-01

    AutoTutor helps students learn by holding a conversation in natural language. AutoTutor is adaptive to the learners' actions, verbal contributions, and in some systems their emotions. Many of AutoTutor's conversation patterns simulate human tutoring, but other patterns implement ideal pedagogies that open the door to computer tutors eclipsing…

  10. Human neutrophils in auto-immunity.

    PubMed

    Thieblemont, Nathalie; Wright, Helen L; Edwards, Steven W; Witko-Sarsat, Véronique

    2016-04-01

    Human neutrophils have great capacity to cause tissue damage in inflammatory diseases via their inappropriate activation to release reactive oxygen species (ROS), proteases and other tissue-damaging molecules. Furthermore, activated neutrophils can release a wide variety of cytokines and chemokines that can regulate almost every element of the immune system. In addition to these important immuno-regulatory processes, activated neutrophils can also release, expose or generate neoepitopes that have the potential to break immune tolerance and result in the generation of autoantibodies, that characterise a number of human auto-immune diseases. For example, in vasculitis, anti-neutrophil cytoplasmic antibodies (ANCA) that are directed against proteinase 3 or myeloperoxidase are neutrophil-derived autoantigens and activated neutrophils are the main effector cells of vascular damage. In other auto-immune diseases, these neutrophil-derived neoepitopes may arise from a number of processes that include release of granule enzymes and ROS, changes in the properties of components of their plasma membrane as a result of activation or apoptosis, and via the release of Neutrophil Extracellular Traps (NETs). NETs are extracellular structures that contain chromatin that is decorated with granule enzymes (including citrullinated proteins) that can act as neo-epitopes to generate auto-immunity. This review therefore describes the processes that can result in neutrophil-mediated auto-immunity, and the role of neutrophils in the molecular pathologies of auto-immune diseases such as vasculitis, rheumatoid arthritis (RA) and systemic lupus erythematosus (SLE). We discuss the potential role of NETs in these processes and some of the debate in the literature regarding the role of this phenomenon in microbial killing, cell death and auto-immunity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Auto-phosphorylation Represses Protein Kinase R Activity.

    PubMed

    Wang, Die; de Weerd, Nicole A; Willard, Belinda; Polekhina, Galina; Williams, Bryan R G; Sadler, Anthony J

    2017-03-10

    The central role of protein kinases in controlling disease processes has spurred efforts to develop pharmaceutical regulators of their activity. A rational strategy to achieve this end is to determine intrinsic auto-regulatory processes, then selectively target these different states of kinases to repress their activation. Here we investigate auto-regulation of the innate immune effector protein kinase R, which phosphorylates the eukaryotic initiation factor 2α to inhibit global protein translation. We demonstrate that protein kinase R activity is controlled by auto-inhibition via an intra-molecular interaction. Part of this mechanism of control had previously been reported, but was then controverted. We account for the discrepancy and extend our understanding of the auto-inhibitory mechanism by identifying that auto-inhibition is paradoxically instigated by incipient auto-phosphorylation. Phosphor-residues at the amino-terminus instigate an intra-molecular interaction that enlists both of the N-terminal RNA-binding motifs of the protein with separate surfaces of the C-terminal kinase domain, to co-operatively inhibit kinase activation. These findings identify an innovative mechanism to control kinase activity, providing insight for strategies to better regulate kinase activity.

  12. Auto-recognition of surfaces and auto-generation of material removal volume for finishing process

    NASA Astrophysics Data System (ADS)

    Kataraki, Pramod S.; Salman Abu Mansor, Mohd

    2018-03-01

    Auto-recognition of a surface and auto-generation of material removal volumes for the so recognised surfaces has become a need to achieve successful downstream manufacturing activities like automated process planning and scheduling. Few researchers have contributed to generation of material removal volume for a product but resulted in material removal volume discontinuity between two adjacent material removal volumes generated from two adjacent faces that form convex geometry. The need for limitation free material removal volume generation was attempted and an algorithm that automatically recognises computer aided design (CAD) model’s surface and also auto-generate material removal volume for finishing process of the recognised surfaces was developed. The surfaces of CAD model are successfully recognised by the developed algorithm and required material removal volume is obtained. The material removal volume discontinuity limitation that occurred in fewer studies is eliminated.

  13. Genotoxic damage in auto body shop workers.

    PubMed

    Siebel, Anna Maria; Basso da Silva, Luciano

    2010-10-01

    Some studies have shown increased DNA damage among car painters, but other professionals working in auto body and paint shops have not been extensively assessed. The aim of this study was to assess DNA damage in different types of auto body shop workers by measuring micronucleus (MN) levels in exfoliated buccal cells. The mean number of cells with MN per 2000 exfoliated buccal cells was analyzed in three groups of male workers: auto body repair technicians, painters, and office workers (control group). All participants answered a questionnaire inquiring about age, smoking habits, alcohol consumption, work practices, occupational exposure time, job activities, and use of protective equipment. The mean number of cells with MN was 3.50 ± 1.50 in auto body painters, 3.91 ± 2.10 in auto body repair technicians, and 0.80 ± 0.78 in office workers, with a significant difference between the control group and the two other groups (p = 0.0001). Age, occupational exposure time, use of protective masks, alcohol consumption, and smoking habit did not affect MN results. The findings indicate that technicians and painters working in auto body shops are at risk for genotoxic damage, while office workers seem to be protected.

  14. Female Infertility and Serum Auto-antibodies: a Systematic Review.

    PubMed

    Deroux, Alban; Dumestre-Perard, Chantal; Dunand-Faure, Camille; Bouillet, Laurence; Hoffmann, Pascale

    2017-08-01

    On average, 10 % of infertile couples have unexplained infertility. Auto-immune disease (systemic lupus erythematosus, anti-phospholipid syndrome) accounts for a part of these cases. In the last 20 years, aspecific auto-immunity, defined as positivity of auto-antibodies in blood sample without clinical or biological criteria for defined diseases, has been evoked in a subpopulation of infertile women. A systematic review was performed (PUBMED) using the MESH search terms "infertility" and "auto-immunity" or "reproductive technique" or "assisted reproduction" or "in vitro fertilization" and "auto-immunity." We retained clinical and physiopathological studies that were applicable to the clinician in assuming joint management of both infertility associated with serum auto-antibodies in women. Thyroid auto-immunity which affects thyroid function could be a cause of infertility; even in euthyroidia, the presence of anti-thyroperoxydase antibodies and/or thyroglobulin are related to infertility. The presence of anti-phospholipid (APL) and/or anti-nuclear (ANA) antibodies seems to be more frequent in the population of infertile women; serum auto-antibodies are associated with early ovarian failure, itself responsible for fertility disorders. However, there exist few publications on this topic. The methods of dosage, as well as the clinical criteria of unexplained infertility deserve to be standardized to allow a precise response to the question of the role of serum auto-antibodies in these women. The direct pathogenesis of this auto-immunity is unknown, but therapeutic immunomodulators, prescribed on a case-by-case basis, could favor pregnancy even in cases of unexplained primary or secondary infertility.

  15. Economic evaluation of epinephrine auto-injectors for peanut allergy.

    PubMed

    Shaker, Marcus; Bean, Katherine; Verdi, Marylee

    2017-08-01

    Three commercial epinephrine auto-injectors were available in the United States in the summer of 2016: EpiPen, Adrenaclick, and epinephrine injection, USP auto-injector. To describe the variation in pharmacy costs among epinephrine auto-injector devices in New England and evaluate the additional expense associated with incremental auto-injector costs. Decision analysis software was used to evaluate costs of the most and least expensive epinephrine auto-injector devices for children with peanut allergy. To evaluate regional variation in epinephrine auto-injector costs, a random sample of New England national and corporate pharmacies was compared with a convenience sample of pharmacies from 10 Canadian provinces. Assuming prescriptions written for 2 double epinephrine packs each year (home and school), the mean costs of food allergy over the 20-year model horizon totaled $58,667 (95% confidence interval [CI] $57,745-$59,588) when EpiPen was prescribed and $45,588 (95% CI $44,873-$46,304) when epinephrine injection, USP auto-injector was prescribed. No effectiveness differences were evident between groups, with 17.19 (95% CI 17.11-17.27) quality-adjusted life years accruing for each subject. The incremental cost per episode of anaphylaxis treated with epinephrine over the model horizon was $12,576 for EpiPen vs epinephrine injection, USP auto-injector. EpiPen costs were lowest at Canadian pharmacies ($96, 95% CI $85-$107). There was price consistency between corporate and independent pharmacies throughout New England by device brand, with the epinephrine injection, USP auto-injector being the most affordable device. Cost differences among epinephrine auto-injectors were significant. More expensive auto-injector brands did not appear to provide incremental benefit. Copyright © 2017 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  16. [Clinical overview of auto-inflammatory diseases].

    PubMed

    Georgin-Lavialle, S; Rodrigues, F; Hentgen, V; Fayand, A; Quartier, P; Bader-Meunier, B; Bachmeyer, C; Savey, L; Louvrier, C; Sarrabay, G; Melki, I; Belot, A; Koné-Paut, I; Grateau, G

    2018-04-01

    Monogenic auto-inflammatory diseases are characterized by genetic abnormalities coding for proteins involved in innate immunity. They were initially described in mirror with auto-immune diseases because of the absence of circulating autoantibodies. Their main feature is the presence of peripheral blood inflammation in crisis without infection. The best-known auto-inflammatory diseases are mediated by interleukines that consisted in the 4 following diseases familial Mediterranean fever, cryopyrinopathies, TNFRSF1A-related intermittent fever, and mevalonate kinase deficiency. Since 10 years, many other diseases have been discovered, especially thanks to the progress in genetics. In this review, we propose the actual panorama of the main known auto-inflammatory diseases. Some of them are recurrent fevers with crisis and remission; some others evaluate more chronically; some are associated with immunodeficiency. From a physiopathological point of view, we can separate diseases mediated by interleukine-1 and diseases mediated by interferon. Then some polygenic inflammatory diseases will be shortly described: Still disease, Schnitzler syndrome, aseptic abscesses syndrome. The diagnosis of auto-inflammatory disease is largely based on anamnesis, the presence of peripheral inflammation during attacks and genetic analysis, which are more and more performant. Copyright © 2018 Société Nationale Française de Médecine Interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  17. Downtown Crossing: Auto Restricted Zone in Boston

    DOT National Transportation Integrated Search

    1982-07-01

    The Downtown Crossing auto restricted zone, implemented in 1978, involved the : elimination of all auto traffic froma zone of twelve blocks encompassing six : different streets in Bostn's central business district. Some of the blocks were : pedestria...

  18. The Implementation of Downtown Auto-Restricted Projects

    DOT National Transportation Integrated Search

    1984-06-01

    In 1975 UMTA's Office of Service and Methods Demonstration launched a demonstration program of Auto Restricted Zones (ARZs) which went beyond the traditional scope of linear pedestrian malls. ARZs involve auto restriction in a large geographic area w...

  19. Monogenic Auto-inflammatory Syndromes: A Review of the Literature.

    PubMed

    Azizi, Gholamreza; Khadem Azarian, Shahin; Nazeri, Sepideh; Mosayebian, Ali; Ghiasy, Saleh; Sadri, Ghazal; Mohebi, Ali; Khan Nazer, Nikoo Hossein; Afraei, Sanaz; Mirshafiey, Abbas

    2016-12-01

    Auto-inflammatory syndromes are a new group of distinct hereditable disorders characterized by episodes of seemingly unprovoked inflammation (most commonly in skin, joints, gut, and eye), the absence of a high titer of auto-antibodies or auto-reactive T cells, and an inborn error of innate immunity. A narrative literature review was carried out of studies related to auto-inflammatory syndromes to discuss the pathogenesis and clinical manifestation of these syndromes. This review showed that the main monogenic auto-inflammatory syndromes are familial Mediterranean fever (FMF), mevalonate kinase deficiency (MKD), Blau syndrome, TNF receptor-associated periodic syndrome (TRAPS), cryopyrin-associated periodic syndrome (CAPS), and pyogenic arthritis with pyoderma gangrenosum and acne (PAPA). The data suggest that correct diagnosis and treatment of monogenic auto-inflammatory diseases relies on the physicians' awareness. Therefore, understanding of the underlying pathogenic mechanisms of auto-inflammatory syndromes, and especially the fact that these disorders are mediated by IL-1 secretion stimulated by monocytes and macrophages, facilitated significant progress in patient management.

  20. AutoCAD-To-NASTRAN Translator Program

    NASA Technical Reports Server (NTRS)

    Jones, A.

    1989-01-01

    Program facilitates creation of finite-element mathematical models from geometric entities. AutoCAD to NASTRAN translator (ACTON) computer program developed to facilitate quick generation of small finite-element mathematical models for use with NASTRAN finite-element modeling program. Reads geometric data of drawing from Data Exchange File (DXF) used in AutoCAD and other PC-based drafting programs. Written in Microsoft Quick-Basic (Version 2.0).

  1. 46 CFR 97.16-1 - Use of auto pilot.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Use of auto pilot. 97.16-1 Section 97.16-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Auto Pilot § 97.16-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...

  2. 46 CFR 97.16-1 - Use of auto pilot.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Use of auto pilot. 97.16-1 Section 97.16-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Auto Pilot § 97.16-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...

  3. 46 CFR 78.19-1 - Use of auto pilot.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 3 2012-10-01 2012-10-01 false Use of auto pilot. 78.19-1 Section 78.19-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Auto Pilot § 78.19-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used in— (a...

  4. 46 CFR 97.16-1 - Use of auto pilot.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Use of auto pilot. 97.16-1 Section 97.16-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Auto Pilot § 97.16-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...

  5. 46 CFR 78.19-1 - Use of auto pilot.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 3 2014-10-01 2014-10-01 false Use of auto pilot. 78.19-1 Section 78.19-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Auto Pilot § 78.19-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used in— (a...

  6. 46 CFR 78.19-1 - Use of auto pilot.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 3 2013-10-01 2013-10-01 false Use of auto pilot. 78.19-1 Section 78.19-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Auto Pilot § 78.19-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used in— (a...

  7. 46 CFR 97.16-1 - Use of auto pilot.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Use of auto pilot. 97.16-1 Section 97.16-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Auto Pilot § 97.16-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...

  8. 46 CFR 78.19-1 - Use of auto pilot.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Use of auto pilot. 78.19-1 Section 78.19-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Auto Pilot § 78.19-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used in— (a...

  9. 46 CFR 78.19-1 - Use of auto pilot.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false Use of auto pilot. 78.19-1 Section 78.19-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Auto Pilot § 78.19-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used in— (a...

  10. 46 CFR 97.16-1 - Use of auto pilot.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Use of auto pilot. 97.16-1 Section 97.16-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Auto Pilot § 97.16-1 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...

  11. The History of the Data Systems AutoChemist® (ACH) and AutoChemist- PRISMA (PRISMA®): from 1964 to 1986.

    PubMed

    Ohlsén, L; Jungner, I; Peterson, H E

    2014-05-22

    This paper presents the history of data system development steps (1964 - 1986) for the clinical analyzers AutoChemist®, and its successor AutoChemist PRISMA® (PRogrammable Individually Selective Modular Analyzer). The paper also partly recounts the history of development steps of the minicomputer PDP 8 from Digital Equipment. The first PDP 8 had 4 core memory boards of 1 K each and was large as a typical oven baking sheet and about 10 years later, PDP 8 was a "one chip microcomputer" with a 32 K memory chip. The fast developments of PDP 8 come to have a strong influence on the development of the data system for AutoChemist. Five major releases of the software were made during this period (1-5 MIACH). The most important aims were not only to calculate the results, but also be able to monitor their quality and automatically manage the orders, store the results in digital form for later statistical analysis and distribute the results to the physician in charge of the patient using thesame computer as the analyzer. Another result of the data system was the ability to customize AutoChemist to handle sample identification by using bar codes and the presentation of results to different types of laboratories. Digital Equipment launched the PDP 8 just as a new minicomputer was desperately needed. No other known alternatives were available at the time. This was to become a key success factor for AutoChemist. That the AutoChemist with such a high capacity required a computer for data collection was obvious already in the early 1960s. That computer development would be so rapid and that one would be able to accomplish so much with a data system was even suspicious at the time. In total, 75; AutoChemist (31) and PRISMA (44) were delivered Worldwide. The last PRISMA was delivered in 1987 to the Veteran Hospital Houston, TX USA.

  12. The History of the Data Systems AutoChemist® (ACH) and AutoChemist-PRISMA (PRISMA®): from 1964 to 1986

    PubMed Central

    2014-01-01

    Summary Objectives This paper presents the history of data system development steps (1964 – 1986) for the clinical analyzers AutoChemist®, and its successor AutoChemist PRISMA® (PRogrammable Individually Selective Modular Analyzer). The paper also partly recounts the history of development steps of the minicomputer PDP 8 from Digital Equipment. The first PDP 8 had 4 core memory boards of 1 K each and was large as a typical oven baking sheet and about 10 years later, PDP 8 was a “one chip microcomputer” with a 32 K memory chip. The fast developments of PDP 8 come to have a strong influence on the development of the data system for AutoChemist. Five major releases of the software were made during this period (1-5 MIACH). Results The most important aims were not only to calculate the results, but also be able to monitor their quality and automatically manage the orders, store the results in digital form for later statistical analysis and distribute the results to the physician in charge of the patient using thesame computer as the analyzer. Another result of the data system was the ability to customize AutoChemist to handle sample identification by using bar codes and the presentation of results to different types of laboratories. Conclusions Digital Equipment launched the PDP 8 just as a new minicomputer was desperately needed. No other known alternatives were available at the time. This was to become a key success factor for AutoChemist. That the AutoChemist with such a high capacity required a computer for data collection was obvious already in the early 1960s. That computer development would be so rapid and that one would be able to accomplish so much with a data system was even suspicious at the time. In total, 75; AutoChemist (31) and PRISMA (44) were delivered Worldwide The last PRISMA was delivered in 1987 to the Veteran Hospital Houston, TX USA PMID:24853032

  13. AUTO-EXPANSIVE FLOW

    EPA Science Inventory

    Physics suggests that the interplay of momentum, continuity, and geometry in outward radial flow must produce density and concomitant pressure reductions. In other words, this flow is intrinsically auto-expansive. It has been proposed that this process is the key to understanding...

  14. Computing Mass Properties From AutoCAD

    NASA Technical Reports Server (NTRS)

    Jones, A.

    1990-01-01

    Mass properties of structures computed from data in drawings. AutoCAD to Mass Properties (ACTOMP) computer program developed to facilitate quick calculations of mass properties of structures containing many simple elements in such complex configurations as trusses or sheet-metal containers. Mathematically modeled in AutoCAD or compatible computer-aided design (CAD) system in minutes by use of three-dimensional elements. Written in Microsoft Quick-Basic (Version 2.0).

  15. Auto-magnetizing liners for magnetized inertial fusion

    DOE PAGES

    Slutz, S. A.; Jennings, C. A.; Awe, T. J.; ...

    2017-01-20

    Here, the MagLIF (Magnetized Liner Inertial Fusion) concept has demonstrated fusion-relevant plasma conditions on the Z accelerator using external field coils to magnetize the fuel before compression. We present a novel concept (AutoMag), which uses a composite liner with helical conduction paths separated by insulating material to provide fuel magnetization from the early part of the drive current, which by design rises slowly enough to avoid electrical breakdown of the insulators. Once the magnetization field is established, the drive current rises more quickly, which causes the insulators to break down allowing the drive current to follow an axial path andmore » implode the liner in the conventional z-pinch manner. There are two important advantages to AutoMag over external field coils for the operation of MagLIF. Low inductance magnetically insulated power feeds can be used to increase the drive current, and AutoMag does not interfere with diagnostic access. Also, AutoMag enables a pathway to energy applications for MagLIF, since expensive field coils will not be damaged each shot. Finally, it should be possible to generate Field Reversed Configurations (FRC) by using both external field coils and AutoMag in opposite polarities. This would provide a means to studying FRC liner implosions on the 100 ns time scale.« less

  16. Double-lumen tubes and auto-PEEP during one-lung ventilation.

    PubMed

    Spaeth, J; Ott, M; Karzai, W; Grimm, A; Wirth, S; Schumann, S; Loop, T

    2016-01-01

    Double-lumen tubes (DLT) are routinely used to enable one-lung-ventilation (OLV) during thoracic anaesthesia. The flow-dependent resistance of the DLT's bronchial limb may be high as a result of its narrow inner diameter and length, and thus potentially contribute to an unintended increase in positive end-expiratory pressure (auto-PEEP). We therefore studied the impact of adult sized DLTs on the dynamic auto-PEEP during OLV. In this prospective clinical study, dynamic auto-PEEP was determined in 72 patients undergoing thoracic surgery, with right- and left-sided DLTs of various sizes. During OLV, air trapping was provoked by increasing inspiration to expiration ratio from 1:2 to 2:1 (five steps). Based on measured flow rate, airway pressure (Paw) and bronchial pressure (Pbronch), the pressure gradient across the DLT (ΔPDLT) and the total auto-PEEP in the respiratory system (i.e. the lungs, the DLT and the ventilator circuit) were determined. Subsequently the DLT's share in total auto-PEEP was calculated. ΔPDLT was 2.3 (0.7) cm H2O over the entire breathing cycle. At the shortest expiratory time the mean total auto-PEEP was 2.9 (1.5) cm H2O (range 0-5.9 cm H2O). The DLT caused 27 to 31% of the total auto-PEEP. Size and side of the DLT's bronchial limb did not impact auto-PEEP significantly. Although the DLT contributes to the overall auto-PEEP, its contribution is small and independent of size and side of the DLT's bronchial limb. The choice of DLT does not influence the risk of auto-PEEP during OLV to a clinically relevant extent. DRKS00005648. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Auto-fusion and the shaping of neurons and tubes.

    PubMed

    Soulavie, Fabien; Sundaram, Meera V

    2016-12-01

    Cells adopt specific shapes that are necessary for specific functions. For example, some neurons extend elaborate arborized dendrites that can contact multiple targets. Epithelial and endothelial cells can form tiny seamless unicellular tubes with an intracellular lumen. Recent advances showed that cells can auto-fuse to acquire those specific shapes. During auto-fusion, a cell merges two parts of its own plasma membrane. In contrast to cell-cell fusion or macropinocytic fission, which result in the merging or formation of two separate membrane bound compartments, auto-fusion preserves one compartment, but changes its shape. The discovery of auto-fusion in C. elegans was enabled by identification of specific protein fusogens, EFF-1 and AFF-1, that mediate cell-cell fusion. Phenotypic characterization of eff-1 and aff-1 mutants revealed that fusogen-mediated fusion of two parts of the same cell can be used to sculpt dendritic arbors, reconnect two parts of an axon after injury, or form a hollow unicellular tube. Similar auto-fusion events recently were detected in vertebrate cells, suggesting that auto-fusion could be a widely used mechanism for shaping neurons and tubes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Auto-fusion and the shaping of neurons and tubes

    PubMed Central

    Soulavie, Fabien; Sundaram, Meera V.

    2016-01-01

    Cells adopt specific shapes that are necessary for specific functions. For example, some neurons extend elaborate arborized dendrites that can contact multiple targets. Epithelial and endothelial cells can form tiny seamless unicellular tubes with an intracellular lumen. Recent advances showed that cells can auto-fuse to acquire those specific shapes. During auto-fusion, a cell merges two parts of its own plasma membrane. In contrast to cell-cell fusion or macropinocytic fission, which result in the merging or formation of two separate membrane bound compartments, auto-fusion preserves one compartment, but changes its shape. The discovery of auto-fusion in C. elegans was enabled by identification of specific protein fusogens, EFF-1 and AFF-1, that mediate cell-cell fusion. Phenotypic characterization of eff-1 and aff-1 mutants revealed that fusogen-mediated fusion of two parts of the same cell can be used to sculpt dendritic arbors, reconnect two parts of an axon after injury, or form a hollow unicellular tube. Similar auto-fusion events recently were detected in vertebrate cells, suggesting that auto-fusion could be a widely used mechanism for shaping neurons and tubes. PMID:27436685

  19. 47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...

  20. 47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...

  1. 47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...

  2. 47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...

  3. 47 CFR 80.307 - Compulsory use of radiotelegraph auto alarm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Compulsory use of radiotelegraph auto alarm. 80.307 Section 80.307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL... Safety Watches § 80.307 Compulsory use of radiotelegraph auto alarm. The radiotelegraph auto alarm...

  4. [Auto-immune disorders as a possible cause of neuropsychiatric syndromes].

    PubMed

    Martinez-Martinez, P; Molenaar, P C; Losen, M; Hoffmann, C; Stevens, J; de Witte, L D; van Amelsvoort, T; van Os, J; Rutten, B P F

    2015-01-01

    Changes that occur in the behaviour of voltage-gated ion channels and ligand-gated receptor channels due to gene mutations or auto-immune attack are the cause of channelopathies in the central and peripheral nervous system. Although the relation between molecular channel defects and clinical symptoms has been explained in the case of many neuromuscular channelopathies, the pathophysiology of auto-immunity in neuropsychiatric syndromes is still unclear. To review recent findings regarding neuronal auto-immune reactions in severe neuropsychiatric syndromes. Using PubMed, we consulted the literature published between 1990 and August 2014 relating to the occurrence of auto-immune antibodies in severe and persistent neuropsychiatric syndromes. Auto-antibodies have only limited access to the central nervous system, but if they do enter the system they can, in some cases, cause disease. We discuss recent findings regarding the occurrence of auto-antibodies against ligand-activated receptor channels and potassium channels in neuropsychiatric and neurological syndromes, including schizophrenia and limbic encephalitis. Although the occurrence of several auto-antibodies in schizophrenia has been confirmed, there is still no proof of a causal relationship in the syndrome. We still have no evidence of the prevalence of auto-immunity in neuropsychiatric syndromes. The discovery that an antibody against an ion channel is associated with some neuropsychiatric disorders may mean that in future it will be possible to treat patients by means of immunosuppression, which could lead to an improvement in a patient's cognitive abilities.

  5. Unintentional Epinephrine Auto-injector Injuries: A National Poison Center Observational Study.

    PubMed

    Anshien, Marco; Rose, S Rutherfoord; Wills, Brandon K

    2016-11-24

    Epinephrine is the only first-line therapeutic agent used to treat life-threatening anaphylaxis. Epinephrine auto-injectors are commonly carried by patients at risk for anaphylaxis, and reported cases of unintentional auto-injector injury have increased over the last decade. Modifications of existing designs and release of a new style of auto-injector are intended to reduce epinephrine auto-injector misuse. The aim of the study was to characterize reported cases of unintentional epinephrine auto-injector exposures from 2013 to 2014 and compare demographics, auto-injector model, and anatomical site of such exposures. The American Association of Poison Control Center's National Poison Data System was searched from January 1, 2013, to December 31, 2014, for cases of unintentional epinephrine auto-injector exposures. Anatomical site data were obtained from all cases reported to the Virginia Poison Center and participating regional poison center for Auvi-Q cases. A total of 6806 cases of unintentional epinephrine auto-injector exposures were reported to US Poison Centers in 2013 and 2014. Of these cases, 3933 occurred with EpiPen, 2829 with EpiPen Jr, 44 with Auvi-Q, and no case reported of Adrenaclick. The most common site of unintentional injection for traditional epinephrine auto-injectors was the digit or thumb, with 58% of cases for EpiPen and 39% of cases with EpiPen Jr. With Auvi-Q, the most common site was the leg (78% of cases). The number of unintentional epinephrine auto-injector cases reported to American Poison Centers in 2013-2014 has increased compared with previous data. Most EpiPen exposures were in the digits, whereas Auvi-Q was most frequently in the leg. Because of the limitations of Poison Center data, more research is needed to identify incidence of unintentional exposures and the effectiveness of epinephrine auto-injector redesign.

  6. Multilevel Parallelization of AutoDock 4.2.

    PubMed

    Norgan, Andrew P; Coffman, Paul K; Kocher, Jean-Pierre A; Katzmann, David J; Sosa, Carlos P

    2011-04-28

    Virtual (computational) screening is an increasingly important tool for drug discovery. AutoDock is a popular open-source application for performing molecular docking, the prediction of ligand-receptor interactions. AutoDock is a serial application, though several previous efforts have parallelized various aspects of the program. In this paper, we report on a multi-level parallelization of AutoDock 4.2 (mpAD4). Using MPI and OpenMP, AutoDock 4.2 was parallelized for use on MPI-enabled systems and to multithread the execution of individual docking jobs. In addition, code was implemented to reduce input/output (I/O) traffic by reusing grid maps at each node from docking to docking. Performance of mpAD4 was examined on two multiprocessor computers. Using MPI with OpenMP multithreading, mpAD4 scales with near linearity on the multiprocessor systems tested. In situations where I/O is limiting, reuse of grid maps reduces both system I/O and overall screening time. Multithreading of AutoDock's Lamarkian Genetic Algorithm with OpenMP increases the speed of execution of individual docking jobs, and when combined with MPI parallelization can significantly reduce the execution time of virtual screens. This work is significant in that mpAD4 speeds the execution of certain molecular docking workloads and allows the user to optimize the degree of system-level (MPI) and node-level (OpenMP) parallelization to best fit both workloads and computational resources.

  7. [Oral diseases in auto-immune polyendocrine syndrome type 1].

    PubMed

    Proust-Lemoine, Emmanuelle; Guyot, Sylvie

    2017-09-01

    Auto-immune polyendocrine syndrome type 1 (APS1) also called Auto-immune Polyendocrinopathy Candidiasis Ectodermal Dystrophy (APECED) is a rare monogenic childhood-onset auto-immune disease. This autosomal recessive disorder is caused by mutations in the auto-immune regulator (AIRE) gene, and leads to autoimmunity targeting peripheral tissues. There is a wide variability in clinical phenotypes in patients with APSI, with auto-immune endocrine and non-endocrine disorders, and chronic mucocutaneous candidiasis. These patients suffer from oral diseases such as dental enamel hypoplasia and candidiasis. Both are frequently described, and in recent series, enamel hypoplasia and candidiasis are even the most frequent components of APS1 together with hypoparathyroidism. Both often occur during childhood (before 5 years old for canrdidiasis, and before 15 years old for enamel hypoplasia). Oral candidiasis is recurrent all life long, could become resistant to azole antifungal after years of treatment, and be carcinogenic, leading to severe oral squamous cell carcinoma. Oral components of APS1 should be diagnosed and rigorously treated. Dental enamel hypoplasia and/or recurrent oral candidiasis in association with auto-immune diseases in a young child should prompt APS1 diagnosis. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  8. Electrical Systems. Auto Mechanics Curriculum Guide Module 2. Instructor's Guide.

    ERIC Educational Resources Information Center

    Hevel, David; Donovan, Roger

    This document is one of a series of modules in the Missouri Auto Mechanics Curriculum Guide, which is based on 144 basic auto mechanics competencies identified on the Missouri Auto Mechanics Competency Profile. The instructor's materials in this document are for a 14-unit secondary education course. The following units are included: (1) principles…

  9. Intrinsic Tau Acetylation Is Coupled to Auto-Proteolytic Tau Fragmentation

    PubMed Central

    Cohen, Todd J.; Constance, Brian H.; Hwang, Andrew W.; James, Michael; Yuan, Chao-Xing

    2016-01-01

    Tau proteins are abnormally aggregated in a range of neurodegenerative tauopathies including Alzheimer’s disease (AD). Recently, tau has emerged as an extensively post-translationally modified protein, among which lysine acetylation is critical for normal tau function and its pathological aggregation. Here, we demonstrate that tau isoforms have different propensities to undergo lysine acetylation, with auto-acetylation occurring more prominently within the lysine-rich microtubule-binding repeats. Unexpectedly, we identified a unique intrinsic property of tau in which auto-acetylation induces proteolytic tau cleavage, thereby generating distinct N- and C-terminal tau fragments. Supporting a catalytic reaction-based mechanism, mapping and mutagenesis studies showed that tau cysteines, which are required for acetyl group transfer, are also essential for auto-proteolytic tau processing. Further mass spectrometry analysis identified the C-terminal 2nd and 4th microtubule binding repeats as potential sites of auto-cleavage. The identification of acetylation-mediated auto-proteolysis provides a new biochemical mechanism for tau self-regulation and warrants further investigation into whether auto-catalytic functions of tau are implicated in AD and other tauopathies. PMID:27383765

  10. Intrinsic Tau Acetylation Is Coupled to Auto-Proteolytic Tau Fragmentation.

    PubMed

    Cohen, Todd J; Constance, Brian H; Hwang, Andrew W; James, Michael; Yuan, Chao-Xing

    2016-01-01

    Tau proteins are abnormally aggregated in a range of neurodegenerative tauopathies including Alzheimer's disease (AD). Recently, tau has emerged as an extensively post-translationally modified protein, among which lysine acetylation is critical for normal tau function and its pathological aggregation. Here, we demonstrate that tau isoforms have different propensities to undergo lysine acetylation, with auto-acetylation occurring more prominently within the lysine-rich microtubule-binding repeats. Unexpectedly, we identified a unique intrinsic property of tau in which auto-acetylation induces proteolytic tau cleavage, thereby generating distinct N- and C-terminal tau fragments. Supporting a catalytic reaction-based mechanism, mapping and mutagenesis studies showed that tau cysteines, which are required for acetyl group transfer, are also essential for auto-proteolytic tau processing. Further mass spectrometry analysis identified the C-terminal 2nd and 4th microtubule binding repeats as potential sites of auto-cleavage. The identification of acetylation-mediated auto-proteolysis provides a new biochemical mechanism for tau self-regulation and warrants further investigation into whether auto-catalytic functions of tau are implicated in AD and other tauopathies.

  11. Enhancing Price Response Programs through Auto-DR: California's 2007 Implementation Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kiliccote, Sila; Wikler, Greg; Chiu, Albert

    2007-12-18

    This paper describes automated demand response (Auto-DR) activities, an innovative effort in California to ensure that DR programs produce effective and sustainable impacts. Through the application of automation and communication technologies coupled with well-designed incentives and DR programs such as Critical Peak Pricing (CPP) and Demand Bidding (DBP), Auto-DR is opening up the opportunity for many different types of buildings to effectively participate in DR programs. We present the results of Auto-DR implementation efforts by the three California investor-owned utilities for the Summer of 2007. The presentation emphasizes Pacific Gas and Electric Company's (PG&E) Auto-DR efforts, which represents the largestmore » in the state. PG&E's goal was to recruit, install, test and operate 15 megawatts of Auto-DR system capability. We describe the unique delivery approaches, including optimizing the utility incentive structures designed to foster an Auto-DR service provider community. We also show how PG&E's Critical Peak Pricing (CPP) and Demand Bidding (DBP) options were called and executed under the automation platform. Finally, we show the results of the Auto-DR systems installed and operational during 2007, which surpassed PG&E's Auto-DR goals. Auto-DR is being implemented by a multi-disciplinary team including the California Investor Owned Utilities (IOUs), energy consultants, energy management control system vendors, the Lawrence Berkeley National Laboratory (LBNL), and the California Energy Commission (CEC).« less

  12. New auto-tuning technique for the hydrogen maser

    NASA Technical Reports Server (NTRS)

    Sydnor, R. L.; Maleki, L.

    1983-01-01

    Auto-tuning of the maser cavity compensates for cavity pulling effect, and other sources of contribution to the long term frequency drift. Schemes previously proposed for the maser cavity auto-tuning can have adverse effects on the performance of the maser. A new scheme is proposed based on the phase relationship between the electric and the magnetic fields inside the cavity. This technique has the desired feature of auto-tuning the cavity with a very high sensitivity and without disturbing the maser performance. Some approaches for the implementation of this scheme and possible areas of difficulty are examined.

  13. StrAuto: automation and parallelization of STRUCTURE analysis.

    PubMed

    Chhatre, Vikram E; Emerson, Kevin J

    2017-03-24

    Population structure inference using the software STRUCTURE has become an integral part of population genetic studies covering a broad spectrum of taxa including humans. The ever-expanding size of genetic data sets poses computational challenges for this analysis. Although at least one tool currently implements parallel computing to reduce computational overload of this analysis, it does not fully automate the use of replicate STRUCTURE analysis runs required for downstream inference of optimal K. There is pressing need for a tool that can deploy population structure analysis on high performance computing clusters. We present an updated version of the popular Python program StrAuto, to streamline population structure analysis using parallel computing. StrAuto implements a pipeline that combines STRUCTURE analysis with the Evanno Δ K analysis and visualization of results using STRUCTURE HARVESTER. Using benchmarking tests, we demonstrate that StrAuto significantly reduces the computational time needed to perform iterative STRUCTURE analysis by distributing runs over two or more processors. StrAuto is the first tool to integrate STRUCTURE analysis with post-processing using a pipeline approach in addition to implementing parallel computation - a set up ideal for deployment on computing clusters. StrAuto is distributed under the GNU GPL (General Public License) and available to download from http://strauto.popgen.org .

  14. Hand dermatitis in auto mechanics and machinists.

    PubMed

    Donovan, Jeffrey C H; Kudla, Irena; Holness, D Linn

    2007-09-01

    Auto mechanics and machinists presenting with suspected allergic contact dermatitis (ACD) have traditionally been patch-tested with a standard screening tray and a specialty tray such as the Oil and Cooling Fluid Series. While this has proven useful for patch-testing the machinist, there is a need for the development of a more specific allergen testing tray for the auto mechanic. The objective of the study was to compare clinical features and patch-test results of auto mechanics and machinists with hand dermatitis to evaluate differences in allergen profiles. We performed a chart review of 33 auto mechanics and 24 machinists referred to our Occupational Contact Dermatitis Clinic from 2002 to 2005 for evaluation of hand dermatitis. With a panel of 84 allergens, 52 positive reactions were detected in 17 cases of ACD in mechanics. The profiles were different from the cases of ACD diagnosed in 10 of 24 machinists. Mechanics and machinists differ in the spectrum of occupational exposures. Patch testing with greater numbers of allergens likely identifies a larger proportion of mechanics with occupationally relevant ACD. Further study is needed to determine the most appropriate allergens to include in a clinically useful "mechanic's tray."

  15. Building a base map with AutoCAD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flarity, S.J.

    1989-12-01

    The fundamental step in the exploration process is building a base map. Consequently, any serious computer exploration program should be capable of providing base maps. Data used in constructing base maps are available from commercial sources such as Tobin. and Petroleum Information. These data sets include line and well data, the line data being latitude longitude vectors, and the ell data any identifying text information for well and their locations. AutoCAD is a commercial program useful in building base maps. Its features include infinite zoom and pan capability, layering, block definition, text dialog boxes, and a command language, AutoLisp. AutoLispmore » provides more power by allowing the geologist to modify the way the program works. Three AutoLisp routines presented here allow geologists to construct a geologic base map from raw Tobin data. The first program, WELLS.LSP, sets up the map environment for the subsequent programs, WELLADD.LSP and LINEADD.LSP. Welladd.lisp reads the Tobin data and spots the well symbols and the identifying information. Lineadd.lsp performs the same task on line and textural information contained within the data set.« less

  16. Virtual Screening with AutoDock: Theory and Practice

    PubMed Central

    Cosconati, Sandro; Forli, Stefano; Perryman, Alex L.; Harris, Rodney; Goodsell, David S.; Olson, Arthur J.

    2011-01-01

    Importance to the field Virtual screening is a computer-based technique for identifying promising compounds to bind to a target molecule of known structure. Given the rapidly increasing number of protein and nucleic acid structures, virtual screening continues to grow as an effective method for the discovery of new inhibitors and drug molecules. Areas covered in this review We describe virtual screening methods that are available in the AutoDock suite of programs, and several of our successes in using AutoDock virtual screening in pharmaceutical lead discovery. What the reader will gain A general overview of the challenges of virtual screening is presented, along with the tools available in the AutoDock suite of programs for addressing these challenges. Take home message Virtual screening is an effective tool for the discovery of compounds for use as leads in drug discovery, and the free, open source program AutoDock is an effective tool for virtual screening. PMID:21532931

  17. AutoTag and AutoSnap: Standardized, semi-automatic capture of regions of interest from whole slide images

    PubMed Central

    Marien, Koen M.; Andries, Luc; De Schepper, Stefanie; Kockx, Mark M.; De Meyer, Guido R.Y.

    2015-01-01

    Tumor angiogenesis is measured by counting microvessels in tissue sections at high power magnification as a potential prognostic or predictive biomarker. Until now, regions of interest1 (ROIs) were selected by manual operations within a tumor by using a systematic uniform random sampling2 (SURS) approach. Although SURS is the most reliable sampling method, it implies a high workload. However, SURS can be semi-automated and in this way contribute to the development of a validated quantification method for microvessel counting in the clinical setting. Here, we report a method to use semi-automated SURS for microvessel counting: • Whole slide imaging with Pannoramic SCAN (3DHISTECH) • Computer-assisted sampling in Pannoramic Viewer (3DHISTECH) extended by two self-written AutoHotkey applications (AutoTag and AutoSnap) • The use of digital grids in Photoshop® and Bridge® (Adobe Systems) This rapid procedure allows traceability essential for high throughput protein analysis of immunohistochemically stained tissue. PMID:26150998

  18. Fast and Adaptive Auto-focusing Microscope

    NASA Astrophysics Data System (ADS)

    Obara, Takeshi; Igarashi, Yasunobu; Hashimoto, Koichi

    Optical microscopes are widely used in biological and medical researches. By using the microscope, we can observe cellular movements including intracellular ions and molecules tagged with fluorescent dyes at a high magnification. However, a freely motile cell easily escapes from a 3D field of view of the typical microscope. Therefore, we propose a novel auto-focusing algorithm and develop a auto-focusing and tracking microscope. XYZ positions of a microscopic stage are feedback controlled to focus and track the cell automatically. A bright-field image is used to estimate a cellular position. XY centroids are used to estimate XY positions of the tracked cell. To estimate Z position, we use a diffraction pattern around the cell membrane. This estimation method is so-called Depth from Diffraction (DFDi). However, this method is not robust for individual differences between cells because the diffraction pattern depends on each cellular shape. Therefore, in this study, we propose a real-time correction of DFDi by using 2D Laplacian of an intracellular area as a goodness of the focus. To evaluate the performance of our developed algorithm and microscope, we auto-focus and track a freely moving paramecium. In this experimental result, the paramecium is auto-focused and kept inside the scope of the microscope during 45s. The evaluated focal error is within 5µm, while a length and a thickness of the paramecium are about 200µm and 50µm, respectively.

  19. 46 CFR 185.360 - Use of auto pilot.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Use of auto pilot. 185.360 Section 185.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) OPERATIONS Miscellaneous Operating Requirements § 185.360 Use of auto pilot. Whenever an automatic pilot is...

  20. 46 CFR 131.960 - Use of auto-pilot.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Use of auto-pilot. 131.960 Section 131.960 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Miscellaneous § 131.960 Use of auto-pilot. When the automatic pilot is used in areas of high traffic density...

  1. 46 CFR 185.360 - Use of auto pilot.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Use of auto pilot. 185.360 Section 185.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) OPERATIONS Miscellaneous Operating Requirements § 185.360 Use of auto pilot. Whenever an automatic pilot is...

  2. 46 CFR 131.960 - Use of auto-pilot.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Use of auto-pilot. 131.960 Section 131.960 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Miscellaneous § 131.960 Use of auto-pilot. When the automatic pilot is used in areas of high traffic density...

  3. 46 CFR 131.960 - Use of auto-pilot.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Use of auto-pilot. 131.960 Section 131.960 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Miscellaneous § 131.960 Use of auto-pilot. When the automatic pilot is used in areas of high traffic density...

  4. 46 CFR 185.360 - Use of auto pilot.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Use of auto pilot. 185.360 Section 185.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) OPERATIONS Miscellaneous Operating Requirements § 185.360 Use of auto pilot. Whenever an automatic pilot is...

  5. 46 CFR 131.960 - Use of auto-pilot.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Use of auto-pilot. 131.960 Section 131.960 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Miscellaneous § 131.960 Use of auto-pilot. When the automatic pilot is used in areas of high traffic density...

  6. 46 CFR 185.360 - Use of auto pilot.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Use of auto pilot. 185.360 Section 185.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) OPERATIONS Miscellaneous Operating Requirements § 185.360 Use of auto pilot. Whenever an automatic pilot is...

  7. Auto Collision Technician: An Instructional Guide for Teachers.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. Vocational Instructional Materials Lab.

    This guide is designed to help teachers in auto collision technician programs for grades 11 and 12 teach the critical competencies of the program. The critical competencies covered are the High Priority-Individual (HP-I) competencies in Ohio's Occupational Competency Assessment Profile (OCAP) for Auto Collision Technician. HP-I competencies are…

  8. 46 CFR 185.360 - Use of auto pilot.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Use of auto pilot. 185.360 Section 185.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) OPERATIONS Miscellaneous Operating Requirements § 185.360 Use of auto pilot. Whenever an automatic pilot is...

  9. 46 CFR 131.960 - Use of auto-pilot.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Use of auto-pilot. 131.960 Section 131.960 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Miscellaneous § 131.960 Use of auto-pilot. When the automatic pilot is used in areas of high traffic density...

  10. Family factors associated with auto-aggressiveness in adolescents in Croatia.

    PubMed

    Tripković, Mara; Francisković, Tanja; Grgić, Neda; Ercegović, Nela; Graovac, Mirjana; Zecević, Iva

    2013-12-01

    The aim of this research is to look into the roles of families' social situation and cohesion in adolescent auto-aggressiveness in Croatia. The research was conducted on a sample of Zagreb high school students which encompassed 701 pupils of both genders aged 14-19. The basic demographic data were obtained using the Structured Demographic and Family Data Questionnaire. Auto-aggressiveness was tested using a section of the Report on Youth Aged 11-18 and the Scale of Auto-destructiveness--SAD, whereas the family cohesion was tested with the Family Adaptability and Cohesion Evaluation Scales FACES III. The obtained results show differences according to the gender: girls are more prone to auto-aggressiveness than boys (t = -3.385, df = 565, p = 0.001) and girls more often show symptoms of destructiveness (t = -3.809, df = 637, p < 0.001) and anxiety (t = -6.562, df = 640, p < 0.001), while boys show pronounced aggressiveness (t = 2.655, df = 653, p = 0.008). Significant family factors associated with auto-aggressiveness are parents' marital status (chi2 = 18.039, df = 4, p = 0.001), their financial situation (F(2.548) = 4.604, p = 0.010), alcoholic father (chi2 = 9.270, df = 2, p = 0.010), mentally ill mother (t = 5.264, df = 541, p < 0.001), as well as mentally ill father (t = 4.744, df = 529, p < 0.001), and corporal punishment by mother (F(2.542) = 8.132, p < 0.001) or father (F(2.530) = 5.341, p = 0.005). Adolescents from split families show more auto-aggressiveness. Family cohesion appears to be considerably associated with auto-aggressiveness and the adolescents that see their families as less cohesive have more mental problems (chi2 = 29.98, df = 2, p < 0.001). There is a connection between auto-destructive behavior in adolescents and family factors. Knowledge of family's social situation and cohesion may help understand, prevent and treat auto-aggressiveness in adolescents.

  11. [Dermatological features of auto-inflammatory recurrent fevers].

    PubMed

    Escudier, A; Mauvais, F-X; Bastard, P; Boussard, C; Jaoui, A; Koskas, V; Lecoq, E; Michel, A; Orcel, M-C; Truelle, P-E; Wohrer, D; Piram, M

    2018-02-01

    Auto-inflammatory diseases are characterized by unexplained and recurrent attacks of systemic inflammation often involving the skin, joints, or serosal membranes. They are due to a dysfunction or dysregulation of the innate immunity, which is the first line of defense against pathogens. Early recognition of these diseases by the clinician, especially by pediatricians encountering such pathologies in pediatric patients, is primordial to avoid complications. Skin manifestations, common in most auto-inflammatory diseases, are helpful for prompt diagnosis. After a brief physiopathological review, we will describe auto-inflammatory recurrent fevers by their main dermatological presentations: urticarial lesions, neutrophilic dermatoses, panniculitis, other maculopapular eruptions, dyskeratosis, skin vasculitis, and oral aphthous. We finally suggest a decision tree to help clinicians better target genetic exams in patients with recurrent fevers and dermatological manifestations. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  12. COSMIC SHEAR MEASUREMENT USING AUTO-CONVOLVED IMAGES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Xiangchong; Zhang, Jun, E-mail: betajzhang@sjtu.edu.cn

    2016-10-20

    We study the possibility of using quadrupole moments of auto-convolved galaxy images to measure cosmic shear. The autoconvolution of an image corresponds to the inverse Fourier transformation of its power spectrum. The new method has the following advantages: the smearing effect due to the point-spread function (PSF) can be corrected by subtracting the quadrupole moments of the auto-convolved PSF; the centroid of the auto-convolved image is trivially identified; the systematic error due to noise can be directly removed in Fourier space; the PSF image can also contain noise, the effect of which can be similarly removed. With a large ensemblemore » of simulated galaxy images, we show that the new method can reach a sub-percent level accuracy under general conditions, albeit with increasingly large stamp size for galaxies of less compact profiles.« less

  13. 46 CFR 109.585 - Use of auto pilot.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Use of auto pilot. 109.585 Section 109.585 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.585 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...

  14. 46 CFR 109.585 - Use of auto pilot.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Use of auto pilot. 109.585 Section 109.585 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.585 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...

  15. 46 CFR 109.585 - Use of auto pilot.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Use of auto pilot. 109.585 Section 109.585 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.585 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...

  16. 46 CFR 109.585 - Use of auto pilot.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Use of auto pilot. 109.585 Section 109.585 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.585 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...

  17. 46 CFR 109.585 - Use of auto pilot.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Use of auto pilot. 109.585 Section 109.585 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Miscellaneous § 109.585 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used...

  18. 46 CFR 122.360 - Use of auto pilot.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Use of auto pilot. 122.360 Section 122.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... Requirements § 122.360 Use of auto pilot. Whenever an automatic pilot is used the master shall ensure that: (a...

  19. 46 CFR 122.360 - Use of auto pilot.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Use of auto pilot. 122.360 Section 122.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... Requirements § 122.360 Use of auto pilot. Whenever an automatic pilot is used the master shall ensure that: (a...

  20. 46 CFR 122.360 - Use of auto pilot.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Use of auto pilot. 122.360 Section 122.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... Requirements § 122.360 Use of auto pilot. Whenever an automatic pilot is used the master shall ensure that: (a...

  1. 46 CFR 122.360 - Use of auto pilot.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Use of auto pilot. 122.360 Section 122.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... Requirements § 122.360 Use of auto pilot. Whenever an automatic pilot is used the master shall ensure that: (a...

  2. 46 CFR 122.360 - Use of auto pilot.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Use of auto pilot. 122.360 Section 122.360 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... Requirements § 122.360 Use of auto pilot. Whenever an automatic pilot is used the master shall ensure that: (a...

  3. Taming parallel I/O complexity with auto-tuning

    DOE PAGES

    Behzad, Babak; Luu, Huong Vu Thanh; Huchette, Joseph; ...

    2013-11-17

    We present an auto-tuning system for optimizing I/O performance of HDF5 applications and demonstrate its value across platforms, applications, and at scale. The system uses a genetic algorithm to search a large space of tunable parameters and to identify effective settings at all layers of the parallel I/O stack. The parameter settings are applied transparently by the auto-tuning system via dynamically intercepted HDF5 calls. To validate our auto-tuning system, we applied it to three I/O benchmarks (VPIC, VORPAL, and GCRM) that replicate the I/O activity of their respective applications. We tested the system with different weak-scaling configurations (128, 2048, andmore » 4096 CPU cores) that generate 30 GB to 1 TB of data, and executed these configurations on diverse HPC platforms (Cray XE6, IBM BG/P, and Dell Cluster). In all cases, the auto-tuning framework identified tunable parameters that substantially improved write performance over default system settings. In conclusion, we consistently demonstrate I/O write speedups between 2x and 100x for test configurations.« less

  4. [DNA Extraction from Old Bones by AutoMate Express™ System].

    PubMed

    Li, B; Lü, Z

    2017-08-01

    To establish a method for extracting DNA from old bones by AutoMate Express™ system. Bones were grinded into powder by freeze-mill. After extraction by AutoMate Express™, DNA were amplified and genotyped by Identifiler®Plus and MinFiler™ kits. DNA were extracted from 10 old bone samples, which kept in different environments with the postmortem interval from 10 to 20 years, in 3 hours by AutoMate Express™ system. Complete STR typing results were obtained from 8 samples. AutoMate Express™ system can quickly and efficiently extract DNA from old bones, which can be applied in forensic practice. Copyright© by the Editorial Department of Journal of Forensic Medicine

  5. What factors affect the carriage of epinephrine auto-injectors by teenagers?

    PubMed Central

    2012-01-01

    Background Teenagers with allergies are at particular risk of severe and fatal reactions, but epinephrine auto-injectors are not always carried as prescribed. We investigated barriers to carriage. Methods Patients aged 12-18 years old under a specialist allergy clinic, who had previously been prescribed an auto-injector were invited to participate. Semi-structured interviews explored the factors that positively or negatively impacted on carriage. Results Twenty teenagers with food or venom allergies were interviewed. Only two patients had used their auto-injector in the community, although several had been treated for severe reactions in hospital. Most teenagers made complex risk assessments to determine whether to carry the auto-injector. Most but not all decisions were rational and were at least partially informed by knowledge. Factors affecting carriage included location, who else would be present, the attitudes of others and physical features of the auto-injector. Teenagers made frequent risk assessments when deciding whether to carry their auto-injectors, and generally wanted to remain safe. Their decisions were complex, multi-faceted and highly individualised. Conclusions Rather than aiming for 100% carriage of auto-injectors, which remains an ambitious ideal, personalised education packages should aim to empower teenagers to make and act upon informed risk assessments. PMID:22409884

  6. What factors affect the carriage of epinephrine auto-injectors by teenagers?

    PubMed

    Macadam, Clare; Barnett, Julie; Roberts, Graham; Stiefel, Gary; King, Rosemary; Erlewyn-Lajeunesse, Michel; Holloway, Judith A; Lucas, Jane S

    2012-02-02

    Teenagers with allergies are at particular risk of severe and fatal reactions, but epinephrine auto-injectors are not always carried as prescribed. We investigated barriers to carriage. Patients aged 12-18 years old under a specialist allergy clinic, who had previously been prescribed an auto-injector were invited to participate. Semi-structured interviews explored the factors that positively or negatively impacted on carriage. Twenty teenagers with food or venom allergies were interviewed. Only two patients had used their auto-injector in the community, although several had been treated for severe reactions in hospital. Most teenagers made complex risk assessments to determine whether to carry the auto-injector. Most but not all decisions were rational and were at least partially informed by knowledge. Factors affecting carriage included location, who else would be present, the attitudes of others and physical features of the auto-injector. Teenagers made frequent risk assessments when deciding whether to carry their auto-injectors, and generally wanted to remain safe. Their decisions were complex, multi-faceted and highly individualised. Rather than aiming for 100% carriage of auto-injectors, which remains an ambitious ideal, personalised education packages should aim to empower teenagers to make and act upon informed risk assessments.

  7. Auto Design

    NASA Technical Reports Server (NTRS)

    1988-01-01

    The 1987 Honda Acura Legend Coupe was designed with aid of the NASA-developed NASTRAN computer program. NASTRAN takes an electronic look at a computerized design and predicts how the structure will react under a great many different conditions. Quick and inexpensive, it minimizes trial and error in the design process and makes possible better, lighter, safer structures while affording significant savings in development time. All Honda auto products designed in the 1980's have been analyzed by the NASTRAN program.

  8. EMISSIONS FROM COATINGS USED IN THE AUTO REFINISHING INDUSTRY

    EPA Science Inventory

    The report presents results of EPA Methods 24 and 311 analyses of the volatile organic compound (VOC) content of selected auto refinishing coatings and their components that are sold by the five major auto coating manufacturers. These analyses were undertaken to determine the acc...

  9. AutoFACT: An Automatic Functional Annotation and Classification Tool

    PubMed Central

    Koski, Liisa B; Gray, Michael W; Lang, B Franz; Burger, Gertraud

    2005-01-01

    Background Assignment of function to new molecular sequence data is an essential step in genomics projects. The usual process involves similarity searches of a given sequence against one or more databases, an arduous process for large datasets. Results We present AutoFACT, a fully automated and customizable annotation tool that assigns biologically informative functions to a sequence. Key features of this tool are that it (1) analyzes nucleotide and protein sequence data; (2) determines the most informative functional description by combining multiple BLAST reports from several user-selected databases; (3) assigns putative metabolic pathways, functional classes, enzyme classes, GeneOntology terms and locus names; and (4) generates output in HTML, text and GFF formats for the user's convenience. We have compared AutoFACT to four well-established annotation pipelines. The error rate of functional annotation is estimated to be only between 1–2%. Comparison of AutoFACT to the traditional top-BLAST-hit annotation method shows that our procedure increases the number of functionally informative annotations by approximately 50%. Conclusion AutoFACT will serve as a useful annotation tool for smaller sequencing groups lacking dedicated bioinformatics staff. It is implemented in PERL and runs on LINUX/UNIX platforms. AutoFACT is available at . PMID:15960857

  10. [Design of blood-pressure parameter auto-acquisition circuit].

    PubMed

    Chen, Y P; Zhang, D L; Bai, H W; Zhang, D A

    2000-02-01

    This paper presents the realization and design of a kind of blood-pressure parameter auto-acquisition circuit. The auto-acquisition of blood-pressure parameter controlled by 89C2051 single chip microcomputer is accomplished by collecting and processing the driving signal of LCD. The circuit that is successfully applied in the home unit of telemedicine system has the simple and reliable properties.

  11. AutoLock: a semiautomated system for radiotherapy treatment plan quality control.

    PubMed

    Dewhurst, Joseph M; Lowe, Matthew; Hardy, Mark J; Boylan, Christopher J; Whitehurst, Philip; Rowbottom, Carl G

    2015-05-08

    A semiautomated system for radiotherapy treatment plan quality control (QC), named AutoLock, is presented. AutoLock is designed to augment treatment plan QC by automatically checking aspects of treatment plans that are well suited to computational evaluation, whilst summarizing more subjective aspects in the form of a checklist. The treatment plan must pass all automated checks and all checklist items must be acknowledged by the planner as correct before the plan is finalized. Thus AutoLock uniquely integrates automated treatment plan QC, an electronic checklist, and plan finalization. In addition to reducing the potential for the propagation of errors, the integration of AutoLock into the plan finalization workflow has improved efficiency at our center. Detailed audit data are presented, demonstrating that the treatment plan QC rejection rate fell by around a third following the clinical introduction of AutoLock.

  12. Auto Mechanics Supplementary Units.

    ERIC Educational Resources Information Center

    Donovan, Roger; Smith, Sam

    This document contains supplemental materials for special needs high school students intended to facilitate their mainstreaming in regular auto mechanics courses. Teacher's materials precede the materials for students and include general notes for the instructor, suggestions, 18 references, a class progress chart, a questionnaire on the usefulness…

  13. Genetic aspects of auto-immune profiles of healthy chickens.

    PubMed

    Parmentier, Henk K; van der Vaart, Priscilla S; Nieuwland, Mike G B; Savelkoul, Huub F J

    2017-09-01

    Auto-antibody profiles binding liver antigens differed between chicken lines divergently selected for specific antibody responses to SRBC, and were affected by ageing suggesting both genetic and environmental effects. Presence and levels of IgM and IgG antibodies binding chicken liver cell lysate (CLL) fragments in plasma at 5 weeks of age from 10 individual full sibs and their parents from 5 H srbc and 5 L srbc line families was studied to reveal genetic relations. Non-genetic maternal effects were studied by comparing auto-antibody profiles of 36 weeks old hens from 2 other unrelated lines with the profiles from their chicks at hatch. IgM and IgG antibodies from parents and progeny from both H srbc and L srbc lines bound CLL fragments. Significant line and generation differences and their interactions were found for both isotypes. Higher staining of CLL fragments was usually found for H srbc line birds. Lines were clustered by auto-antibody profiles, but staining by birds of both lines in both generations was very individual for IgG and IgM. The current data with full sibs therefore not supported a genetic basis for auto-antibody profiles. IgG but not IgM auto-antibody profiles of chicks correlated with maternal auto-antibody profiles. The results suggest that the auto-antibody repertoire of healthy chickens is largely stochastically initiated and may be affected by environmental challenges during ageing, but genetic mechanisms may underlie staining intensity of individual bound CLL fragments. The present results suggest that identification of fragments or profiles to be used at early age for genetic selection for health traits is not feasible yet. Secondly, the IgM profile of neonatal chickens seems non-organised independent of the maternal profile, but the neonatal IgG profile is much more related with the maternal profile. Consequences of these findings for disease susceptibility or breeding for optimal health are discussed. Copyright © 2017 Elsevier Ltd. All

  14. Identification of the regulatory autophosphorylation site of autophosphorylation-dependent protein kinase (auto-kinase). Evidence that auto-kinase belongs to a member of the p21-activated kinase family.

    PubMed

    Yu, J S; Chen, W J; Ni, M H; Chan, W H; Yang, S D

    1998-08-15

    Autophosphorylation-dependent protein kinase (auto-kinase) was identified from pig brain and liver on the basis of its unique autophosphorylation/activation property [Yang, Fong, Yu and Liu (1987) J. Biol. Chem. 262, 7034-7040; Yang, Chang and Soderling (1987) J. Biol. Chem. 262, 9421-9427]. Its substrate consensus sequence motif was determined as being -R-X-(X)-S*/T*-X3-S/T-. To characterize auto-kinase further, we partly sequenced the kinase purified from pig liver. The N-terminal sequence (VDGGAKTSDKQKKKAXMTDE) and two internal peptide sequences (EKLRTIV and LQNPEK/ILTP/FI) of auto-kinase were obtained. These sequences identify auto-kinase as a C-terminal catalytic fragment of p21-activated protein kinase 2 (PAK2 or gamma-PAK) lacking its N-terminal regulatory region. Auto-kinase can be recognized by an antibody raised against the C-terminal peptide of human PAK2 by immunoblotting. Furthermore the autophosphorylation site sequence of auto-kinase was successfully predicted on the basis of its substrate consensus sequence motif and the known PAK2 sequence, and was further demonstrated to be RST(P)MVGTPYWMAPEVVTR by phosphoamino acid analysis, manual Edman degradation and phosphopeptide mapping via the help of phosphorylation site analysis of a synthetic peptide corresponding to the sequence of PAK2 from residues 396 to 418. During the activation process, auto-kinase autophosphorylates mainly on a single threonine residue Thr402 (according to the sequence numbering of human PAK2). In addition, a phospho-specific antibody against a synthetic phosphopeptide containing this identified sequence was generated and shown to be able to differentially recognize the activated auto-kinase autophosphorylated at Thr402 but not the non-phosphorylated/inactive auto-kinase. Immunoblot analysis with this phospho-specific antibody further revealed that the change in phosphorylation level of Thr402 of auto-kinase was well correlated with the activity change of the kinase during both

  15. Identification of the regulatory autophosphorylation site of autophosphorylation-dependent protein kinase (auto-kinase). Evidence that auto-kinase belongs to a member of the p21-activated kinase family.

    PubMed Central

    Yu, J S; Chen, W J; Ni, M H; Chan, W H; Yang, S D

    1998-01-01

    Autophosphorylation-dependent protein kinase (auto-kinase) was identified from pig brain and liver on the basis of its unique autophosphorylation/activation property [Yang, Fong, Yu and Liu (1987) J. Biol. Chem. 262, 7034-7040; Yang, Chang and Soderling (1987) J. Biol. Chem. 262, 9421-9427]. Its substrate consensus sequence motif was determined as being -R-X-(X)-S*/T*-X3-S/T-. To characterize auto-kinase further, we partly sequenced the kinase purified from pig liver. The N-terminal sequence (VDGGAKTSDKQKKKAXMTDE) and two internal peptide sequences (EKLRTIV and LQNPEK/ILTP/FI) of auto-kinase were obtained. These sequences identify auto-kinase as a C-terminal catalytic fragment of p21-activated protein kinase 2 (PAK2 or gamma-PAK) lacking its N-terminal regulatory region. Auto-kinase can be recognized by an antibody raised against the C-terminal peptide of human PAK2 by immunoblotting. Furthermore the autophosphorylation site sequence of auto-kinase was successfully predicted on the basis of its substrate consensus sequence motif and the known PAK2 sequence, and was further demonstrated to be RST(P)MVGTPYWMAPEVVTR by phosphoamino acid analysis, manual Edman degradation and phosphopeptide mapping via the help of phosphorylation site analysis of a synthetic peptide corresponding to the sequence of PAK2 from residues 396 to 418. During the activation process, auto-kinase autophosphorylates mainly on a single threonine residue Thr402 (according to the sequence numbering of human PAK2). In addition, a phospho-specific antibody against a synthetic phosphopeptide containing this identified sequence was generated and shown to be able to differentially recognize the activated auto-kinase autophosphorylated at Thr402 but not the non-phosphorylated/inactive auto-kinase. Immunoblot analysis with this phospho-specific antibody further revealed that the change in phosphorylation level of Thr402 of auto-kinase was well correlated with the activity change of the kinase during both

  16. An Instructional Method for the AutoCAD Modeling Environment.

    ERIC Educational Resources Information Center

    Mohler, James L.

    1997-01-01

    Presents a command organizer for AutoCAD to aid new uses in operating within the 3-D modeling environment. Addresses analyzing the problem, visualization skills, nonlinear tools, a static view of a dynamic model, the AutoCAD organizer, environment attributes, and control of the environment. Contains 11 references. (JRH)

  17. Depression and auto-aggressiveness in adolescents in Zagreb.

    PubMed

    Tripković, Mara; Vuković, Iris Sarajlić; Frančišković, Tanja; Pisk, Sandra Vuk; Krnić, Silvana

    2014-12-01

    The aim of the study was to explore the frequency of depression among the general population of adolescents who were high school students in the city of Zagreb. As depression is associated with increased suicidal risk we wanted to check to what extent depression, as an emotional problem among youth, is associated with auto-aggression in the general population of adolescents. The study was conducted on a sample of high school students in Zagreb and it included 701 students of both genders aged from 14-19 years of age. To test the depression a Beck Depression Inventory (BDI) was administered for youth between 11-18 years of age (Youth Self Report for ages 11-18). To test auto-aggression a Scale of Auto-destructiveness (SAD) was used. Results obtained by this study show that about 20.7% of high school students have mild and borderline depressive disorders while moderate or severe depression shows about 5% of them, whereby depression is statistically significant among girls who, on average, report more symptoms of depression. It has also been proven a significant impact of depression levels (F (2,423)=35.860, p<0.001) on auto-aggression in subjects of both genders. In both genders, moderately depressed show more auto destructiveness than those without depression symptoms (p<0.01). In the group of heavily depressed (n=30), significantly higher self-destructiveness is shown by girls (p<0.01). The data suggest the importance of early recognition, understanding and treatment of depressive symptoms in adolescents in order to reduce the risk of subsequent chronic psychosocial damage.

  18. AutoBayes Program Synthesis System Users Manual

    NASA Technical Reports Server (NTRS)

    Schumann, Johann; Jafari, Hamed; Pressburger, Tom; Denney, Ewen; Buntine, Wray; Fischer, Bernd

    2008-01-01

    Program synthesis is the systematic, automatic construction of efficient executable code from high-level declarative specifications. AutoBayes is a fully automatic program synthesis system for the statistical data analysis domain; in particular, it solves parameter estimation problems. It has seen many successful applications at NASA and is currently being used, for example, to analyze simulation results for Orion. The input to AutoBayes is a concise description of a data analysis problem composed of a parameterized statistical model and a goal that is a probability term involving parameters and input data. The output is optimized and fully documented C/C++ code computing the values for those parameters that maximize the probability term. AutoBayes can solve many subproblems symbolically rather than having to rely on numeric approximation algorithms, thus yielding effective, efficient, and compact code. Statistical analysis is faster and more reliable, because effort can be focused on model development and validation rather than manual development of solution algorithms and code.

  19. AutoLock: a semiautomated system for radiotherapy treatment plan quality control

    PubMed Central

    Lowe, Matthew; Hardy, Mark J.; Boylan, Christopher J.; Whitehurst, Philip; Rowbottom, Carl G.

    2015-01-01

    A semiautomated system for radiotherapy treatment plan quality control (QC), named AutoLock, is presented. AutoLock is designed to augment treatment plan QC by automatically checking aspects of treatment plans that are well suited to computational evaluation, whilst summarizing more subjective aspects in the form of a checklist. The treatment plan must pass all automated checks and all checklist items must be acknowledged by the planner as correct before the plan is finalized. Thus AutoLock uniquely integrates automated treatment plan QC, an electronic checklist, and plan finalization. In addition to reducing the potential for the propagation of errors, the integration of AutoLock into the plan finalization workflow has improved efficiency at our center. Detailed audit data are presented, demonstrating that the treatment plan QC rejection rate fell by around a third following the clinical introduction of AutoLock. PACS number: 87.55.Qr PMID:26103498

  20. Parallel auto-correlative statistics with VTK.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pebay, Philippe Pierre; Bennett, Janine Camille

    2013-08-01

    This report summarizes existing statistical engines in VTK and presents both the serial and parallel auto-correlative statistics engines. It is a sequel to [PT08, BPRT09b, PT09, BPT09, PT10] which studied the parallel descriptive, correlative, multi-correlative, principal component analysis, contingency, k-means, and order statistics engines. The ease of use of the new parallel auto-correlative statistics engine is illustrated by the means of C++ code snippets and algorithm verification is provided. This report justifies the design of the statistics engines with parallel scalability in mind, and provides scalability and speed-up analysis results for the autocorrelative statistics engine.

  1. AutoCAD-To-GIFTS Translator Program

    NASA Technical Reports Server (NTRS)

    Jones, Andrew

    1989-01-01

    AutoCAD-to-GIFTS translator program, ACTOG, developed to facilitate quick generation of small finite-element models using CASA/GIFTS finite-element modeling program. Reads geometric data of drawing from Data Exchange File (DXF) used in AutoCAD and other PC-based drafting programs. Geometric entities recognized by ACTOG include points, lines, arcs, solids, three-dimensional lines, and three-dimensional faces. From this information, ACTOG creates GIFTS SRC file, which then reads into GIFTS preprocessor BULKM or modified and reads into EDITM to create finite-element model. SRC file used as is or edited for any number of uses. Written in Microsoft Quick-Basic (Version 2.0).

  2. Research on remote sensing image pixel attribute data acquisition method in AutoCAD

    NASA Astrophysics Data System (ADS)

    Liu, Xiaoyang; Sun, Guangtong; Liu, Jun; Liu, Hui

    2013-07-01

    The remote sensing image has been widely used in AutoCAD, but AutoCAD lack of the function of remote sensing image processing. In the paper, ObjectARX was used for the secondary development tool, combined with the Image Engine SDK to realize remote sensing image pixel attribute data acquisition in AutoCAD, which provides critical technical support for AutoCAD environment remote sensing image processing algorithms.

  3. AutoClickChem: click chemistry in silico.

    PubMed

    Durrant, Jacob D; McCammon, J Andrew

    2012-01-01

    Academic researchers and many in industry often lack the financial resources available to scientists working in "big pharma." High costs include those associated with high-throughput screening and chemical synthesis. In order to address these challenges, many researchers have in part turned to alternate methodologies. Virtual screening, for example, often substitutes for high-throughput screening, and click chemistry ensures that chemical synthesis is fast, cheap, and comparatively easy. Though both in silico screening and click chemistry seek to make drug discovery more feasible, it is not yet routine to couple these two methodologies. We here present a novel computer algorithm, called AutoClickChem, capable of performing many click-chemistry reactions in silico. AutoClickChem can be used to produce large combinatorial libraries of compound models for use in virtual screens. As the compounds of these libraries are constructed according to the reactions of click chemistry, they can be easily synthesized for subsequent testing in biochemical assays. Additionally, in silico modeling of click-chemistry products may prove useful in rational drug design and drug optimization. AutoClickChem is based on the pymolecule toolbox, a framework that may facilitate the development of future python-based programs that require the manipulation of molecular models. Both the pymolecule toolbox and AutoClickChem are released under the GNU General Public License version 3 and are available for download from http://autoclickchem.ucsd.edu.

  4. AutoClickChem: Click Chemistry in Silico

    PubMed Central

    Durrant, Jacob D.; McCammon, J. Andrew

    2012-01-01

    Academic researchers and many in industry often lack the financial resources available to scientists working in “big pharma.” High costs include those associated with high-throughput screening and chemical synthesis. In order to address these challenges, many researchers have in part turned to alternate methodologies. Virtual screening, for example, often substitutes for high-throughput screening, and click chemistry ensures that chemical synthesis is fast, cheap, and comparatively easy. Though both in silico screening and click chemistry seek to make drug discovery more feasible, it is not yet routine to couple these two methodologies. We here present a novel computer algorithm, called AutoClickChem, capable of performing many click-chemistry reactions in silico. AutoClickChem can be used to produce large combinatorial libraries of compound models for use in virtual screens. As the compounds of these libraries are constructed according to the reactions of click chemistry, they can be easily synthesized for subsequent testing in biochemical assays. Additionally, in silico modeling of click-chemistry products may prove useful in rational drug design and drug optimization. AutoClickChem is based on the pymolecule toolbox, a framework that may facilitate the development of future python-based programs that require the manipulation of molecular models. Both the pymolecule toolbox and AutoClickChem are released under the GNU General Public License version 3 and are available for download from http://autoclickchem.ucsd.edu. PMID:22438795

  5. Crashworthiness Assessment of Auto-body Members Considering the Fabrication Histories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huh, Hoon; Song, Jung-Han; Kim, Kee-Poong

    2005-08-05

    This paper is concerned with crashworthiness of auto-body members considering the effect of fabrication. Most auto-body members are fabricated with sheet metal forming process and welding process that induce fabrication histories such as the plastic work hardening, non-uniform thickness distribution and residual stress. Crash simulation is carried out for auto-body members with LS-DYNA3D in order to identify the fabrication effect on the crashworthiness. The analysis calculated crash mode, the reaction force and the energy absorption for crashworthiness assessment with the forming effect. The result shows that the crash analysis with considering the forming history leads to a different result frommore » that without considering the forming effect. The analysis results demonstrate that the design of auto-body members should be carried out considering the forming history for accurate assessment of the crashworthiness.« less

  6. 46 CFR 167.65-35 - Use of auto pilot.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Use of auto pilot. 167.65-35 Section 167.65-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS PUBLIC NAUTICAL SCHOOL SHIPS Special Operating Requirements § 167.65-35 Use of auto pilot. Except as provided in 33 CFR 164.15, when...

  7. 46 CFR 167.65-35 - Use of auto pilot.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Use of auto pilot. 167.65-35 Section 167.65-35 Shipping... Special Operating Requirements § 167.65-35 Use of auto pilot. Except as provided in 33 CFR 164.15, when the automatic pilot is used in— (a) Areas of high traffic density; (b) Conditions of restricted...

  8. AUTO PARTS MAN, WORKBOOK.

    ERIC Educational Resources Information Center

    DOVER, BUEL H.

    THE INFORMATION IN THIS STUDY GUIDE WAS DEVELOPED FOR USE IN THE RELATED TECHNICAL CLASSROOM INSTRUCTION PHASE OF THE AUTO PARTS MAN APPRENTICE TRAINING PROGRAM. THE MATERIAL WAS PLANNED UNDER THE DIRECTION OF THE STATE EDUCATIONAL ADVISORY COMMITTEE FOR THE AUTOMOTIVE TRADE. THE UNITS ARE (1) SCOPE AND OPPORTUNITY, (2) AREAS OF RESPONSIBILITY,…

  9. Stitching-aware in-design DPT auto fixing for sub-20nm logic devices

    NASA Astrophysics Data System (ADS)

    Choi, Soo-Han; Sai Krishna, K. V. V. S.; Pemberton-Smith, David

    2017-03-01

    As the technology continues to shrink below 20nm, Double Patterning Technology (DPT) becomes one of the mandatory solutions for routing metal layers. From the view point of Place and Route (P&R), the major concerns are how to prevent DPT odd-cycles automatically without sacrificing chip area. Even though the leading-edge P&R tools have advanced algorithms to prevent DPT odd-cycles, it is very hard to prevent the localized DPT odd-cycles, especially in Engineering Change Order (ECO) routing. In the last several years, we developed In-design DPT Auto Fixing method in order to reduce localized DPT odd-cycles significantly during ECO and could achieve remarkable design Turn-Around Times (TATs). But subsequently, as the design complexity continued increasing and chip size continued decreasing, we needed a new In-design DPT Auto Fixing approach to improve the auto. fixing rate. In this paper, we present the Stitching-Aware In-design DPT Auto Fixing method for better fixing rates and smaller chip design. The previous In-design DPT Auto Fixing method detected all DPT odd-cycles and tried to remove oddcycles by increasing the adjacent space. As the metal congestions increase in the newer technology nodes, the older Auto Fixing method has limitations to increase the adjacent space between routing metals. Consequently, the auto fixing rate of older method gets worse with the introduction of the smaller design rules. With DPT stitching enablement at In-design DRC checking procedure, the new Stitching-Aware DPT Auto Fixing method detects the most critical odd-cycles and revolve the odd-cycles automatically. The accuracy of new flow ensures better usage of space in the congested areas, and helps design more smaller chips. By applying the Stitching-Aware DPT Auto Fixing method to sub-20nm logic devices, we can confirm that the auto fixing rate is improved by 2X compared with auto fixing without stitching. Additionally, by developing the better heuristic algorithm and flow for DPT

  10. A Code Generation Approach for Auto-Vectorization in the Spade Compiler

    NASA Astrophysics Data System (ADS)

    Wang, Huayong; Andrade, Henrique; Gedik, Buğra; Wu, Kun-Lung

    We describe an auto-vectorization approach for the Spade stream processing programming language, comprising two ideas. First, we provide support for vectors as a primitive data type. Second, we provide a C++ library with architecture-specific implementations of a large number of pre-vectorized operations as the means to support language extensions. We evaluate our approach with several stream processing operators, contrasting Spade's auto-vectorization with the native auto-vectorization provided by the GNU gcc and Intel icc compilers.

  11. Neuropsychiatric lupus and auto-antibodies against ionotropic glutamate receptor (NMDAR)

    PubMed Central

    Cohen-Solal, J.F.G.; Diamond, B.

    2010-01-01

    Almost half of lupus patients will experience neuropsychiatric symptoms during the course of their disease. The etiology of the neuronal damages are still uncertain and probably multiple. Auto-antibodies reactive with brain have been postulated to play a role. The observation of pathogenic auto-antibodies binding the NR2A and NR2B subunits of the ionotropic glutamate receptor (NMDAR) illustrates this hypothesis. First studies showed that 40% of lupus patients possess serum titers of anti-NR2A/B antibody, but the presence of these auto-antibodies is not always associated with the occurrence of neuronal damages or neuropsychiatric symptoms. Nevertheless, their presence is observed in the cerebro-spinal fluid (CSF) of one half of the patients suffering from neurolupus. The presence in the serum of these auto-antibodies anti-NR2A/B of the NMDAR is preliminary to their presence in the CSF where their deleterious effect is observable. Their entry into the brain is dependent on a breach of the blood brain barrier (BBB). In conclusion, the serum titer of auto-antibodies against NR2A/B subunits is an indication of the potential for neuro-psychiatric manifestations during the course of the disease. PMID:20605660

  12. The auto-amputated adnexa: a review of findings in a pediatric population.

    PubMed

    Focseneanu, Mariel A; Omurtag, Kenan; Ratts, Valerie S; Merritt, Diane F

    2013-12-01

    To quantify our experience and that of the literature with diagnosis and management of the auto-amputated adnexa in a pediatric population. Case series and literature review. Tertiary care medical center. Case series of pediatric patients (<18 years of age) with surgically documented adnexal auto-amputation collected from our medical center and the literature. None. Auto-amputated adnexa. In addition to the 3 cases discussed from our institution, 91 cases of auto-amputated adnexa were identified in the literature dating back to 1943, for a total of 94 cases. Forty-nine percent (46/94) of the cases involved girls in a pediatric population (<18 years of age). Of these, the majority (n = 26) were identified in a subgroup of girls who were diagnosed with an adnexal cyst by antenatal ultrasound. Most of these neonates were asymptomatic at birth or had a palpable abdominal mass (n = 6) and at the time of surgical exploration were found to have an auto-amputated adnexa. 34 out of 46 cases were analyzed in detail. The right adnexa were involved in 56% of the cases. The most common presenting complaint verbalized by the older girls was pain; however, 8 cases were identified in asymptomatic girls undergoing unrelated diagnostic testing. The auto-amputated adnexa is a rare finding in the pediatric population, but it must be considered as a possible explanation for the incidental finding of absence of the fallopian tube or ovary in the subgroup of patients who undergo surgery for any reason. Patients with an antecedent history of pelvic pain either chronic or intermittent in nature may be diagnosed with torsion or less frequently auto-amputation of the adnexa. A fetal "pelvic mass" or "ovarian cyst" may predispose the adnexa to torsion and subsequent auto-amputation either in-utero or post-delivery. Many of these antenatally diagnosed cysts and even subsequent auto-amputations are completely asymptomatic, however, and do not compromise fertility assuming the contralateral

  13. Outpatient Utilization by Infants Auto-assigned to Medicaid Managed Care Plans

    PubMed Central

    Cohn, Lisa M.; Clark, Sarah J.

    2013-01-01

    To test the hypothesis that infants auto-assigned to a Medicaid managed care plan would have lower primary care and higher emergency department (ED) utilization compared to infants with a chosen plan. Retrospective cohort study. Medicaid administrative data were used to identify all children 0–3 months of age at enrollment in Michigan Medicaid managed care in 2005–2008 with 18-months of subsequent enrollment. Medicaid encounter and state immunization registry data were then acquired. Auto-assigned infants were compared versus chosen plan infants on: (1) well-child visits (WCVs); (2) immunizations; (3) acute office visits; and (4) ED visits. Chi squared and rank-sum tests and logistic and negative binomial regression were used in bivariate and multivariable analyses for dichotomous and count data, respectively. 18 % of infants were auto-assigned. Auto-assigned infants were less likely to meet goal number of WCVs in 18-months of managed care enrollment (32 vs. 53 %, p < 0.001) and to be up-to-date on immunizations at 12 months of age (75 vs. 85 %, p < 0.001). Auto-assigned infants had fewer acute office visits (median: 4 vs. 5, p < 0.001) but were only slightly more likely to have 2 or more ED visits (51 vs. 46 %, p < 0.001) in 18-months of enrollment. All results were significant in multivariable analyses. Auto-assigned infants were less likely to use preventive and acute primary care but only slightly more likely to use emergency care. Future work is needed to understand mechanisms of differences in utilization, but auto-assigned children may represent a target group for efforts to promote pediatric preventive care in Medicaid. PMID:23775252

  14. Outpatient utilization by infants auto-assigned to Medicaid managed care plans.

    PubMed

    Zickafoose, Joseph S; Cohn, Lisa M; Clark, Sarah J

    2014-04-01

    To test the hypothesis that infants auto-assigned to a Medicaid managed care plan would have lower primary care and higher emergency department (ED) utilization compared to infants with a chosen plan. Retrospective cohort study. Medicaid administrative data were used to identify all children 0-3 months of age at enrollment in Michigan Medicaid managed care in 2005-2008 with 18-months of subsequent enrollment. Medicaid encounter and state immunization registry data were then acquired. Auto-assigned infants were compared versus chosen plan infants on: (1) well-child visits (WCVs); (2) immunizations; (3) acute office visits; and (4) ED visits. Chi squared and rank-sum tests and logistic and negative binomial regression were used in bivariate and multivariable analyses for dichotomous and count data, respectively. 18% of infants were auto-assigned. Auto-assigned infants were less likely to meet goal number of WCVs in 18-months of managed care enrollment (32 vs. 53%, p < 0.001) and to be up-to-date on immunizations at 12 months of age (75 vs. 85%, p < 0.001). Auto-assigned infants had fewer acute office visits (median: 4 vs. 5, p < 0.001) but were only slightly more likely to have 2 or more ED visits (51 vs. 46%, p < 0.001) in 18-months of enrollment. All results were significant in multivariable analyses. Auto-assigned infants were less likely to use preventive and acute primary care but only slightly more likely to use emergency care. Future work is needed to understand mechanisms of differences in utilization, but auto-assigned children may represent a target group for efforts to promote pediatric preventive care in Medicaid.

  15. Administration of the adrenaline auto-injector at the nursery/kindergarten/school in Western Japan.

    PubMed

    Korematsu, Seigo; Fujitaka, Michiko; Ogata, Mika; Zaitsu, Masafumi; Motomura, Chikako; Kuzume, Kazuyo; Toku, Yuchiro; Ikeda, Masanori; Odajima, Hiroshi

    2017-01-01

    In view of the increasing prevalence of food allergies, there has been an associated increase in frequency of situations requiring an emergency response for anaphylaxis at the home, childcare facilities and educational institutions. To clarify the situation of adrenaline auto-injector administration in nursery/kindergarten/school, we carried out a questionnaire survey on pediatric physicians in Western Japan. In 2015, self-reported questionnaires were mailed to 421 physicians who are members of the West Japan Research Society Pediatric Clinical Allergy and Shikoku Research Society Pediatric Clinical Allergy. The response rate was 44% (185 physicians) where 160 physicians had a prescription registration for the adrenaline auto-injector. In the past year, 1,330 patients were prescribed the adrenaline auto-injector where 83 patients (6% of the prescribed patients) actually administered the adrenaline auto-injector, of which 14 patients (17% of the administered patients) self-administered the adrenaline auto-injector. "Guardians" at the nursery/kindergarten and elementary school were found to have administered the adrenaline auto-injector the most. Among 117 adrenaline auto-injector prescription-registered physicians, 79% had experienced nonadministration of adrenaline auto-injector at nursery/kindergarten/school when anaphylaxis has occurred. The most frequent reason cited for not administering the adrenaline auto-injector was "hesitation about the timing of administration." If the adrenaline auto-injector was administered after the guardian arrived at the nursery/kindergarten/school, it may lead to delayed treatment of anaphylaxis in which symptoms develop in minutes. Education and cooperation among physicians and nursery/kindergarten/school staff will reduce the number of children suffering unfortunate outcomes due to anaphylaxis.

  16. A visual LISP program for voxelizing AutoCAD solid models

    NASA Astrophysics Data System (ADS)

    Marschallinger, Robert; Jandrisevits, Carmen; Zobl, Fritz

    2015-01-01

    AutoCAD solid models are increasingly recognized in geological and geotechnical 3D modeling. In order to bridge the currently existing gap between AutoCAD solid models and the grid modeling realm, a Visual LISP program is presented that converts AutoCAD solid models into voxel arrays. Acad2Vox voxelizer works on a 3D-model that is made up of arbitrary non-overlapping 3D-solids. After definition of the target voxel array geometry, 3D-solids are scanned at grid positions and properties are streamed to an ASCII output file. Acad2Vox has a novel voxelization strategy that combines a hierarchical reduction of sampling dimensionality with an innovative use of AutoCAD-specific methods for a fast and memory-saving operation. Acad2Vox provides georeferenced, voxelized analogs of 3D design data that can act as regions-of-interest in later geostatistical modeling and simulation. The Supplement includes sample geological solid models with instructions for practical work with Acad2Vox.

  17. Fast auto-focus scheme based on optical defocus fitting model

    NASA Astrophysics Data System (ADS)

    Wang, Yeru; Feng, Huajun; Xu, Zhihai; Li, Qi; Chen, Yueting; Cen, Min

    2018-04-01

    An optical defocus fitting model-based (ODFM) auto-focus scheme is proposed. Considering the basic optical defocus principle, the optical defocus fitting model is derived to approximate the potential-focus position. By this accurate modelling, the proposed auto-focus scheme can make the stepping motor approach the focal plane more accurately and rapidly. Two fitting positions are first determined for an arbitrary initial stepping motor position. Three images (initial image and two fitting images) at these positions are then collected to estimate the potential-focus position based on the proposed ODFM method. Around the estimated potential-focus position, two reference images are recorded. The auto-focus procedure is then completed by processing these two reference images and the potential-focus image to confirm the in-focus position using a contrast based method. Experimental results prove that the proposed scheme can complete auto-focus within only 5 to 7 steps with good performance even under low-light condition.

  18. Analysis on the workspace of palletizing robot based on AutoCAD

    NASA Astrophysics Data System (ADS)

    Li, Jin-quan; Zhang, Rui; Guan, Qi; Cui, Fang; Chen, Kuan

    2017-10-01

    In this paper, a four-degree-of-freedom articulated palletizing robot is used as the object of research. Based on the analysis of the overall configuration of the robot, the kinematic mathematical model is established by D-H method to figure out the workspace of the robot. In order to meet the needs of design and analysis, using AutoCAD secondary development technology and AutoLisp language to develop AutoCAD-based 2D and 3D workspace simulation interface program of palletizing robot. At last, using AutoCAD plugin, the influence of structural parameters on the shape and position of the working space is analyzed when the structure parameters of the robot are changed separately. This study laid the foundation for the design, control and planning of palletizing robots.

  19. Auto Body Repair. Supplementary Units. Instructor Key and Student Units.

    ERIC Educational Resources Information Center

    Daniel, Linda; Muench, James F., Ed.

    These supplementary units are designed to help students with special needs learn and apply auto body repair skills. The material specifically supplements the Auto Body Repair Curriculum Guide (University of Missouri-Columbia 1988), and is intended for instructors serving the occupational needs of various categories of disadvantaged and handicapped…

  20. 46 CFR 28.875 - Radar, depth sounding, and auto-pilot.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Radar, depth sounding, and auto-pilot. 28.875 Section 28.875 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.875 Radar, depth sounding, and auto-pilot...

  1. 46 CFR 28.875 - Radar, depth sounding, and auto-pilot.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false Radar, depth sounding, and auto-pilot. 28.875 Section 28.875 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.875 Radar, depth sounding, and auto-pilot...

  2. 46 CFR 28.875 - Radar, depth sounding, and auto-pilot.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Radar, depth sounding, and auto-pilot. 28.875 Section 28.875 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.875 Radar, depth sounding, and auto-pilot...

  3. 46 CFR 28.875 - Radar, depth sounding, and auto-pilot.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Radar, depth sounding, and auto-pilot. 28.875 Section 28.875 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.875 Radar, depth sounding, and auto-pilot...

  4. AutoTutor and Family: A Review of 17 Years of Natural Language Tutoring

    ERIC Educational Resources Information Center

    Nye, Benjamin D.; Graesser, Arthur C.; Hu, Xiangen

    2014-01-01

    AutoTutor is a natural language tutoring system that has produced learning gains across multiple domains (e.g., computer literacy, physics, critical thinking). In this paper, we review the development, key research findings, and systems that have evolved from AutoTutor. First, the rationale for developing AutoTutor is outlined and the advantages…

  5. Deep Marginalized Sparse Denoising Auto-Encoder for Image Denoising

    NASA Astrophysics Data System (ADS)

    Ma, Hongqiang; Ma, Shiping; Xu, Yuelei; Zhu, Mingming

    2018-01-01

    Stacked Sparse Denoising Auto-Encoder (SSDA) has been successfully applied to image denoising. As a deep network, the SSDA network with powerful data feature learning ability is superior to the traditional image denoising algorithms. However, the algorithm has high computational complexity and slow convergence rate in the training. To address this limitation, we present a method of image denoising based on Deep Marginalized Sparse Denoising Auto-Encoder (DMSDA). The loss function of Sparse Denoising Auto-Encoder is marginalized so that it satisfies both sparseness and marginality. The experimental results show that the proposed algorithm can not only outperform SSDA in the convergence speed and training time, but also has better denoising performance than the current excellent denoising algorithms, including both the subjective and objective evaluation of image denoising.

  6. Auto Service. Vocational Preparation Curriculum.

    ERIC Educational Resources Information Center

    Usoro, Hogan

    Intended for instructors serving the occupational needs of disadvantaged and handicapped students, this curriculum guide contains 21 units for an auto service program. Its purposes are to provide minimum skills for students entering the mainstream, supplement vocational skills of students already mainstreamed, and provide vocational instructional…

  7. The Relationship between Affective States and Dialog Patterns during Interactions with AutoTutor

    ERIC Educational Resources Information Center

    Graesser, Arthur C.; D'Mello, Sidney K.; Craig, Scotty D.; Witherspoon, Amy; Sullins, Jeremiah; McDaniel, Bethany; Gholson, Barry

    2008-01-01

    Relations between emotions (affect states) and learning have recently been explored in the context of AutoTutor. AutoTutor is a tutoring system on the Internet that helps learners construct answers to difficult questions by interacting with them in natural language. AutoTutor has an animated conversation agent and a dialog management facility that…

  8. Manual Drive Train and Axles. Auto Mechanics Curriculum Guide Module 7. Instructor's Guide.

    ERIC Educational Resources Information Center

    Colesworthy, Robert; Donovan, Roger

    This document is one of a series of modules in the Missouri Auto Mechanics Curriculum Guide, which is based on 144 basic auto mechanics competencies identified on the Missouri Auto Mechanics Competency Profile. The instructor's materials in this document are for a 13-unit secondary education course. The following units are included: (1)…

  9. Dentists versus auto mechanics: are there ethical differences?

    PubMed

    Riley, Crystal

    2013-01-01

    The different ethical perspectives of dentists and auto mechanics include primary concern, billing procedures, advertising, emergency care, the level of autonomy granted to their patients/ clients, the amount of disclosure given to their patients/clients, the ability to judge the work of others, and the freedom to pursue romantic relationships with their patients/clients. In analyzing these differences, one finds dentists to have much greater ethical obligations than auto mechanics. There are subtle differences between the ethical expectations of Canadian and United States dentists.

  10. Beyond NextGen: AutoMax Overview and Update

    NASA Technical Reports Server (NTRS)

    Kopardekar, Parimal; Alexandrov, Natalia

    2013-01-01

    Main Message: National and Global Needs - Develop scalable airspace operations management system to accommodate increased mobility needs, emerging airspace uses, mix, future demand. Be affordable and economically viable. Sense of Urgency. Saturation (delays), emerging airspace uses, proactive development. Autonomy is Needed for Airspace Operations to Meet Future Needs. Costs, time critical decisions, mobility, scalability, limits of cognitive workload. AutoMax to Accommodate National and Global Needs. Auto: Automation, autonomy, autonomicity for airspace operations. Max: Maximizing performance of the National Airspace System. Interesting Challenges and Path Forward.

  11. Ping-pong auto-zero amplifier with glitch reduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larson, Mark R

    A ping-pong amplifier with reduced glitching is described. The ping-pong amplifier includes a nulling amplifier coupled to a switching network. The switching network is used to auto-zero a ping amplifier within a ping-pong amplifier. The nulling amplifier drives the output of a ping amplifier to a proper output voltage level during auto-zeroing of the ping amplifier. By being at a proper output voltage level, glitches associated with transitioning between a ping amplifier and a pong amplifier are reduced or eliminated.

  12. 46 CFR 28.875 - Radar, depth sounding, and auto-pilot.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Radar, depth sounding, and auto-pilot. 28.875 Section 28... COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.875 Radar, depth sounding, and auto-pilot. (a) Each vessel must be fitted with a general marine radar system for surface navigation with a radar...

  13. Testing First-Order Logic Axioms in AutoCert

    NASA Technical Reports Server (NTRS)

    Ahn, Ki Yung; Denney, Ewen

    2009-01-01

    AutoCert [2] is a formal verification tool for machine generated code in safety critical domains, such as aerospace control code generated from MathWorks Real-Time Workshop. AutoCert uses Automated Theorem Provers (ATPs) [5] based on First-Order Logic (FOL) to formally verify safety and functional correctness properties of the code. These ATPs try to build proofs based on user provided domain-specific axioms, which can be arbitrary First-Order Formulas (FOFs). These axioms are the most crucial part of the trusted base, since proofs can be submitted to a proof checker removing the need to trust the prover and AutoCert itself plays the part of checking the code generator. However, formulating axioms correctly (i.e. precisely as the user had really intended) is non-trivial in practice. The challenge of axiomatization arise from several dimensions. First, the domain knowledge has its own complexity. AutoCert has been used to verify mathematical requirements on navigation software that carries out various geometric coordinate transformations involving matrices and quaternions. Axiomatic theories for such constructs are complex enough that mistakes are not uncommon. Second, adjusting axioms for ATPs can add even more complexity. The axioms frequently need to be modified in order to have them in a form suitable for use with ATPs. Such modifications tend to obscure the axioms further. Thirdly, speculating validity of the axioms from the output of existing ATPs is very hard since theorem provers typically do not give any examples or counterexamples.

  14. [THREE CASES OF ACCIDENTAL AUTO-INJECTION OF ADRENALINE].

    PubMed

    Yanagida, Noriyuki; Iikura, Katsuhito; Ogura, Kiyotake; Wang, Ling-jen; Asaumi, Tomoyuki; Sato, Sakura; Ebisawa, Motohiro

    2015-12-01

    Reports on accidental auto-injection of adrenaline are few. We encountered three cases of accidental injection of adrenaline. In this study, we have examined and reported the clinical courses and symptoms of our cases. CASE 1 involved a female physician in her 50s who had attended an explanatory meeting on auto-injection of adrenaline. She mistook EpiPen® to be the EpiPen trainer and accidentally injected herself with 0.3 mg EpiPen®. Her systolic/diastolic pressure peaked at 7 min to reach 144/78 mmHg and decreased to 120/77 mmHg at 14 min. Except for palpitation after 7 min, the only subjective symptom was local pain at the injection site. CASE 2 was noted in a 6-year-old boy. He accidentally pierced his right forefinger with 0.15 mg EpiPen®, and after 20 min, his right forefinger was swollen. The swelling improved 80 min after the accidental injection. CASE 3 was noted in a 4-year-old girl. She accidentally injected herself with 0.15 mg EpiPen®. Her systolic/diastolic pressure peaked at 23 min to reach 123/70 mmHg and decreased to 96/86 mmHg at 28 min. Severe adverse effects of accidental auto-injection of adrenaline were not observed in these three cases. Our findings suggest that while handling adrenaline auto-injectors, we should keep in mind the possibility of accidental injection.

  15. Auto-Bäcklund transformations for a matrix partial differential equation

    NASA Astrophysics Data System (ADS)

    Gordoa, P. R.; Pickering, A.

    2018-07-01

    We derive auto-Bäcklund transformations, analogous to those of the matrix second Painlevé equation, for a matrix partial differential equation. We also then use these auto-Bäcklund transformations to derive matrix equations involving shifts in a discrete variable, a process analogous to the use of the auto-Bäcklund transformations of the matrix second Painlevé equation to derive a discrete matrix first Painlevé equation. The equations thus derived then include amongst other examples a semidiscrete matrix equation which can be considered to be an extension of this discrete matrix first Painlevé equation. The application of this technique to the auto-Bäcklund transformations of the scalar case of our partial differential equation has not been considered before, and so the results obtained here in this scalar case are also new. Other equations obtained here using this technique include a scalar semidiscrete equation which arises in the case of the second Painlevé equation, and which does not seem to have been thus derived previously.

  16. The Auto-Gopher: A Wireline Rotary-Percussive Deep Sampler

    NASA Technical Reports Server (NTRS)

    Bar-Cohen, Yoseph; Zacny, Kris; Badescu, Mircea; Lee, Hyeong Jae; Sherrit, Stewart; Bao, Xiaoqi; Paulsen, Gale L.; Beegle, Luther

    2016-01-01

    Accessing regions on planetary bodies that potentially preserved biosignatures or are presently habitable is vital to meeting NASA solar system "Search for Life" exploration objectives. To address these objectives, a wireline deep rotary-percussive corer called Auto-Gopher was developed. The percussive action provides effective material fracturing and the rotation provides effective cuttings removal. To increase the drill's penetration rate, the percussive and rotary motions are operated simultaneously. Initially, the corer was designed as a percussive mechanism for sampling ice and was demonstrated in 2005 in Antarctica reaching about 2 m deep. The lessons learned suggested the need to use a combination of rotation and hammering to maximize the penetration rate. This lesson was implemented into the Auto-Gopher-I deep drill which was demonstrated to reach 3-meter deep in gypsum. The average drilling power that was used has been in the range of 100-150 Watt, while the penetration rate was approximately 2.4 m/hr. Recently, a task has started with the goal to develop Auto-Gopher-II that is equipped to execute all the necessary functions in a single drilling unit. These functions also include core breaking, retention and ejection in addition drilling. In this manuscript, the Auto-Gopher-II, its predecessors and their capability are described and discussed.

  17. Gene-Auto: Automatic Software Code Generation for Real-Time Embedded Systems

    NASA Astrophysics Data System (ADS)

    Rugina, A.-E.; Thomas, D.; Olive, X.; Veran, G.

    2008-08-01

    This paper gives an overview of the Gene-Auto ITEA European project, which aims at building a qualified C code generator from mathematical models under Matlab-Simulink and Scilab-Scicos. The project is driven by major European industry partners, active in the real-time embedded systems domains. The Gene- Auto code generator will significantly improve the current development processes in such domains by shortening the time to market and by guaranteeing the quality of the generated code through the use of formal methods. The first version of the Gene-Auto code generator has already been released and has gone thought a validation phase on real-life case studies defined by each project partner. The validation results are taken into account in the implementation of the second version of the code generator. The partners aim at introducing the Gene-Auto results into industrial development by 2010.

  18. Investigating the Simulink Auto-Coding Process

    NASA Technical Reports Server (NTRS)

    Gualdoni, Matthew J.

    2016-01-01

    Model based program design is the most clear and direct way to develop algorithms and programs for interfacing with hardware. While coding "by hand" results in a more tailored product, the ever-growing size and complexity of modern-day applications can cause the project work load to quickly become unreasonable for one programmer. This has generally been addressed by splitting the product into separate modules to allow multiple developers to work in parallel on the same project, however this introduces new potentials for errors in the process. The fluidity, reliability and robustness of the code relies on the abilities of the programmers to communicate their methods to one another; furthermore, multiple programmers invites multiple potentially differing coding styles into the same product, which can cause a loss of readability or even module incompatibility. Fortunately, Mathworks has implemented an auto-coding feature that allows programmers to design their algorithms through the use of models and diagrams in the graphical programming environment Simulink, allowing the designer to visually determine what the hardware is to do. From here, the auto-coding feature handles converting the project into another programming language. This type of approach allows the designer to clearly see how the software will be directing the hardware without the need to try and interpret large amounts of code. In addition, it speeds up the programming process, minimizing the amount of man-hours spent on a single project, thus reducing the chance of human error as well as project turnover time. One such project that has benefited from the auto-coding procedure is Ramses, a portion of the GNC flight software on-board Orion that has been implemented primarily in Simulink. Currently, however, auto-coding Ramses into C++ requires 5 hours of code generation time. This causes issues if the tool ever needs to be debugged, as this code generation will need to occur with each edit to any part of

  19. Parameterized Micro-benchmarking: An Auto-tuning Approach for Complex Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, Wenjing; Krishnamoorthy, Sriram; Agrawal, Gagan

    2012-05-15

    Auto-tuning has emerged as an important practical method for creating highly optimized implementations of key computational kernels and applications. However, the growing complexity of architectures and applications is creating new challenges for auto-tuning. Complex applications can involve a prohibitively large search space that precludes empirical auto-tuning. Similarly, architectures are becoming increasingly complicated, making it hard to model performance. In this paper, we focus on the challenge to auto-tuning presented by applications with a large number of kernels and kernel instantiations. While these kernels may share a somewhat similar pattern, they differ considerably in problem sizes and the exact computation performed.more » We propose and evaluate a new approach to auto-tuning which we refer to as parameterized micro-benchmarking. It is an alternative to the two existing classes of approaches to auto-tuning: analytical model-based and empirical search-based. Particularly, we argue that the former may not be able to capture all the architectural features that impact performance, whereas the latter might be too expensive for an application that has several different kernels. In our approach, different expressions in the application, different possible implementations of each expression, and the key architectural features, are used to derive a simple micro-benchmark and a small parameter space. This allows us to learn the most significant features of the architecture that can impact the choice of implementation for each kernel. We have evaluated our approach in the context of GPU implementations of tensor contraction expressions encountered in excited state calculations in quantum chemistry. We have focused on two aspects of GPUs that affect tensor contraction execution: memory access patterns and kernel consolidation. Using our parameterized micro-benchmarking approach, we obtain a speedup of up to 2 over the version that used default optimizations

  20. Item Response Theory analysis of the Autonomy over Tobacco Scale (AUTOS).

    PubMed

    Wellman, Robert J; Edelen, Maria Orlando; DiFranza, Joseph R

    2015-06-01

    The Autonomy over Tobacco Scale (AUTOS) is composed of 12-symptoms of nicotine dependence. While it has demonstrated excellent reliability and validity, several psychometric properties have yet to be investigated. We aimed to determine (1) whether items functioned differently across demographic groups, (2) the likelihood that individual symptoms would be endorsed by smokers at different levels of diminished autonomy, and (3) the degree of information provided by each item and the reliability of the full AUTOS across the range of diminished autonomy. Data for this study come from two convenience samples of American adult current smokers (n=777; 69% female; 88% white; Mage=34 years, range: 18-78), of whom 66% were daily smokers (Mcigarettes/smoking day=10.1, range: <1-70). Participants completed the AUTOS online as part of "a research study about the experiences people have when they smoke." After p value correction, items remained invariant across sex and minority status, while two items functioned differently according to age, with minimal impact on the total AUTOS score. Discriminative power of the items was high. The greatest amount of information is provided at just under one-half SD above the mean and the least at the extremes of diminished autonomy. The AUTOS maintains acceptable reliability (>0.70) across the range of diminished autonomy within which more than 95% of smokers' scores could be anticipated to fall. The AUTOS is a versatile and psychometrically sound instrument for measuring the loss of autonomy over tobacco use. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. A Real-Time Non-invasive Auto-bioluminescent Urinary Bladder Cancer Xenograft Model.

    PubMed

    John, Bincy Anu; Xu, Tingting; Ripp, Steven; Wang, Hwa-Chain Robert

    2017-02-01

    The study was to develop an auto-bioluminescent urinary bladder cancer (UBC) xenograft animal model for pre-clinical research. The study used a humanized, bacteria-originated lux reporter system consisting of six (luxCDABEfrp) genes to express components required for producing bioluminescent signals in human UBC J82, J82-Ras, and SW780 cells without exogenous substrates. Immune-deficient nude mice were inoculated with Lux-expressing UBC cells to develop auto-bioluminescent xenograft tumors that were monitored by imaging and physical examination. Lux-expressing auto-bioluminescent J82-Lux, J82-Ras-Lux, and SW780-Lux cell lines were established. Xenograft tumors derived from tumorigenic Lux-expressing auto-bioluminescent J82-Ras-Lux cells allowed a serial, non-invasive, real-time monitoring by imaging of tumor development prior to the presence of palpable tumors in animals. Using Lux-expressing auto-bioluminescent tumorigenic cells enabled us to monitor the entire course of xenograft tumor development through tumor cell implantation, adaptation, and growth to visible/palpable tumors in animals.

  2. Auto Mechanics: Scope and Sequence.

    ERIC Educational Resources Information Center

    Nashville - Davidson County Metropolitan Public Schools, TN.

    This scope and sequence guide, developed for an auto mechanics vocational education program, represents an initial step in the development of a systemwide articulated curriculum sequence for all vocational programs within the Metropolitan Nashville Public School System. It was developed as a result of needs expressed by teachers, parents, and the…

  3. Feedback circuit design of an auto-gating power supply for low-light-level image intensifier

    NASA Astrophysics Data System (ADS)

    Yang, Ye; Yan, Bo; Zhi, Qiang; Ni, Xiao-bing; Li, Jun-guo; Wang, Yu; Yao, Ze

    2015-11-01

    This paper introduces the basic principle of auto-gating power supply which using a hybrid automatic brightness control scheme. By the analysis of current as image intensifier to special requirements of auto-gating power supply, a feedback circuit of the auto-gating power supply is analyzed. Find out the reason of the screen flash after the auto-gating power supply assembled image intensifier. This paper designed a feedback circuit which can shorten the response time of auto-gating power supply and improve screen slight flicker phenomenon which the human eye can distinguish under the high intensity of illumination.

  4. AutoCPAP initiation at home: optimal trial duration and cost-effectiveness.

    PubMed

    Bachour, Adel; Virkkala, Jussi T; Maasilta, Paula K

    2007-11-01

    The duration of automatic computer-controlled continuous positive airway pressure device (autoCPAP) initiation at home varies largely between sleep centers. Our objectives were to evaluate the cost-effectiveness and to find the optimal trial duration. Of the 206 consecutive CPAP-naive patients with obstructive sleep apnea syndrome, who were referred to our hospital, 166 received autoCPAP for a 5-day trial at home. Of the 166 patients, 89 (15 women) showed a successful 5-day autoCPAP trial (normalized oximetry and mask-on time exceeding 4 h/day for at least 4 days). For the first trial day, 88 (53%) patients had normalized oximetry and a mask-on time exceeding 4 h. A 1-day autoCPAP trial EUR 668 was less cost-effective than a 5-day trial EUR 653, with no differences in values of efficient CPAP pressure or residual apnea-hypopnea index (AHI). The systematic requirement of oximetry monitoring raised the cost considerably from EUR 481 to EUR 668. In selected patients with obstructive sleep apnea, the optimal duration for initiating CPAP therapy at home by autoCPAP is 5 days. Although a 1-day trial was sufficient to determine the CPAP pressure requirement, it was not cost-effective and had a high rate of failure.

  5. Should we systematically test patients with clinically isolated syndrome for auto-antibodies?

    PubMed

    Negrotto, Laura; Tur, Carmen; Tintoré, Mar; Arrambide, Georgina; Sastre-Garriga, Jaume; Río, Jordi; Comabella, Manuel; Nos, Carlos; Galán, Ingrid; Vidal-Jordana, Angela; Simon, Eva; Castilló, Joaquín; Palavra, Filipe; Mitjana, Raquel; Auger, Cristina; Rovira, Àlex; Montalban, Xavier

    2015-12-01

    Several autoimmune diseases (ADs) can mimic multiple sclerosis (MS). For this reason, testing for auto-antibodies (auto-Abs) is often included in the diagnostic work-up of patients with a clinically isolated syndrome (CIS). The purpose was to study how useful it was to systematically determine antinuclear-antibodies, anti-SSA and anti-SSB in a non-selected cohort of CIS patients, regarding the identification of other ADs that could represent an alternative diagnosis. From a prospective CIS cohort, we selected 772 patients in which auto-Ab levels were tested within the first year from CIS. Baseline characteristics of auto-Ab positive and negative patients were compared. A retrospective revision of clinical records was then performed in the auto-Ab positive patients to identify those who developed ADs during follow-up. One or more auto-Ab were present in 29.4% of patients. Only 1.8% of patients developed other ADs during a mean follow-up of 6.6 years. In none of these cases the concurrent AD was considered the cause of the CIS. In all cases the diagnosis of the AD resulted from the development of signs and/or symptoms suggestive of each disease. Antinuclear-antibodies, anti-SSA and anti-SSB should not be routinely determined in CIS patients but only in those presenting symptoms suggestive of other ADs. © The Author(s), 2015.

  6. Tuba-ovarian auto-amputation caused by ovarian teratoma in an adolescent girl.

    PubMed

    Atıcı, Ahmet; Yılmaz, Engin; Karaman, Ayşe; Apaydın, Sema; Afşarlar, Çağatay Evrim

    2017-01-01

    Atıcı A, Yılmaz E, Karaman A, Apaydın S, Afşarlar ÇE. Tuba-ovarian auto-amputation caused by ovarian teratoma in an adolescent girl. Turk J Pediatr 2017; 59: 90-92. Ovarian auto-amputation is an extremely rare condition commonly encountered in the perinatal period. Spontaneous or secondary torsion of the ovary caused by an ovarian lesion may result in infarction and subsequent auto-amputation of the ovary. This paper demonstrates a case that underwent laparoscopic appendectomy with an incidental calcified auto-amputated right ovary. A 16-year-old adolescent girl was admitted to our department with a history of one-day abdominal pain. Physical examination of the patient revealed abdominal tenderness and rigidity on right lower quadrant. Her white blood cell count was 11x103/mL, and C-reactive protein was 69 mg/L. The patient underwent a laparoscopic appendectomy with a provisional diagnosis of acute appendicitis, and further exploration revealed a 2x2 cm white ovoid mass floating freely in the pelvis. The left ovary was clearly identified in its usual localization, but the right tuba was blindly ending without any fimbria or ovary. Postoperative course of the patient was uneventful, and she was discharged on postoperative day 2. The histopathological examination revealed a necrotic calcified ovarian teratoma. Auto-amputated ovary is a rare occasion mostly encountered during perinatal period, and it may be unilateral or bilateral. An auto-amputated ovarian mass may rarely be a teratoma although the most common cause of auto-amputation during perinatal and adolescent period is ovarian torsion due to an ovarian cyst.

  7. Survey of Auto Mechanic Employers.

    ERIC Educational Resources Information Center

    Page, Charles; Scott, David C.

    In order to build auto mechanics curricula and instructional programs responsive to the needs of employers, Bakersfield College (BC) sent a questionnaire to all employers listed under "Automobile Repairing and Services" in the yellow pages of the local telephone book. Only 43 (20 percent) of the 215 questionnaires sent out were returned;…

  8. An auto-biotinylated bifunctional protein nanowire for ultra-sensitive molecular biosensing.

    PubMed

    Men, Dong; Zhang, Zhi-Ping; Guo, Yong-Chao; Zhu, Duan-Hao; Bi, Li-Jun; Deng, Jiao-Yu; Cui, Zong-Qiang; Wei, Hong-Ping; Zhang, Xian-En

    2010-12-15

    In order to obtain an ultra-sensitive molecular biosensor, we designed an auto-biotinylated bifunctional protein nanowire (bFPNw) based on the self-assembly of a yeast amyloid protein, Sup35, to which protein G and a biotin acceptor peptide (BAP) were genetically fused. These auto-biotinylated bFPNws can transfer hundreds of commercially available diagnostic enzymes to an antigen-antibody complex via the biotin-avidin system, greatly enhancing the sensitivity of immune-biosensing. Compared to our previously reported seeding-induced bFPNws (Men et al., 2009), these auto-biotinylated bFPNws gave greater signal amplification, reduced non-specific binding and improved stability. The auto-biotinylated self-assembled bFPNw molecular biosensors were applied to detect Yersinia pestis (Y. pestis) F1 antigen and showed a 2000- to 4000-fold increase in sensitivity compared to traditional immunoassays, demonstrating the potential use of these self-assembling protein nanowires in biosensing. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. A hydrogen maser with cavity auto-tuner for timekeeping

    NASA Technical Reports Server (NTRS)

    Lin, C. F.; He, J. W.; Zhai, Z. C.

    1992-01-01

    A hydrogen maser frequency standard for timekeeping was worked on at the Shanghai Observatory. The maser employs a fast cavity auto-tuner, which can detect and compensate the frequency drift of the high-Q resonant cavity with a short time constant by means of a signal injection method, so that the long term frequency stability of the maser standard is greatly improved. The cavity auto-tuning system and some maser data obtained from the atomic time comparison are described.

  10. Clinical utility of anti-p53 auto-antibody: systematic review and focus on colorectal cancer.

    PubMed

    Suppiah, Aravind; Greenman, John

    2013-08-07

    Mutation of the p53 gene is a key event in the carcinogenesis of many different types of tumours. These can occur throughout the length of the p53 gene. Anti-p53 auto-antibodies are commonly produced in response to these p53 mutations. This review firstly describes the various mechanisms of p53 dysfunction and their association with subsequent carcinogenesis. Following this, the mechanisms of induction of anti-p53 auto-antibody production are shown, with various hypotheses for the discrepancies between the presence of p53 mutation and the presence/absence of anti-p53 auto-antibodies. A systematic review was performed with a descriptive summary of key findings of each anti-p53 auto-antibody study in all cancers published in the last 30 years. Using this, the cumulative frequency of anti-p53 auto-antibody in each cancer type is calculated and then compared with the incidence of p53 mutation in each cancer to provide the largest sample calculation and correlation between mutation and anti-p53 auto-antibody published to date. Finally, the review focuses on the data of anti-p53 auto-antibody in colorectal cancer studies, and discusses future strategies including the potentially promising role using anti-p53 auto-antibody presence in screening and surveillance.

  11. Diagnostic Utility of Auto-Antibodies in Inflammatory Muscle Diseases.

    PubMed

    Allenbach, Y; Benveniste, O

    2015-01-01

    To date, there are four main groups of idiopathic inflammatory myopathies (IIM): polymyositis (PM), dermatomyositis (DM), immune-mediated necrotizing myopathy (IMNM) and sporadic inclusion body myositis; based on clinical presentation and muscle pathology. Nevertheless, important phenotypical differences (either muscular and/or extra-muscular manifestations) within a group persist. In recent years, the titration of different myositis-specific (or associated) auto-antibodies as a diagnostic tool has increased. This is an important step forward since it may facilitate, at a viable cost, the differential diagnosis between IIM and other myopathies. We have now routine access to assays for the detection of different antibodies. For example, IMNM are related to the presence of anti-SRP or anti-HMGCR. PM is associated with anti-synthetase antibodies (anti-Jo-1, PL-7, PL-12, OJ, and EJ) and DM with anti-Mi-2, anti-SAE, anti-TIF-1-γ and anti-NXP2 (both associated with cancer) or anti-MDA5 antibodies (associated with interstitial lung disease). Today, over 30 myositis specific and associated antibodies have been characterised, and all groups of myositis may present one of those auto-antibodies. Most of them allow identification of homogenous patient groups, more precisely than the classical international classifications of myositis. This implies that classification criteria could be modified accordingly, since these auto-antibodies delineate groups of patients suffering from myositis with consistent clinical phenotype (muscular and extra-muscular manifestations), common prognostic (cancer association, presence of interstitial lung disease, mortality and risk of relapse) and treatment responses. Nevertheless, since numerous auto-antibodies have been recently characterised, the exact prevalence of myositis specific antibodies remains to be documented, and research of new auto-antibodies in the remaining seronegative group is still needed.

  12. Automatic Assembly of Combined Checkingfixture for Auto-Body Components Based Onfixture Elements Libraries

    NASA Astrophysics Data System (ADS)

    Jiang, Jingtao; Sui, Rendong; Shi, Yan; Li, Furong; Hu, Caiqi

    In this paper 3-D models of combined fixture elements are designed, classified by their functions, and saved in computer as supporting elements library, jointing elements library, basic elements library, localization elements library, clamping elements library, and adjusting elements library etc. Then automatic assembly of 3-D combined checking fixture for auto-body part is presented based on modularization theory. And in virtual auto-body assembly space, Locating constraint mapping technique and assembly rule-based reasoning technique are used to calculate the position of modular elements according to localization points and clamp points of auto-body part. Auto-body part model is transformed from itself coordinate system space to virtual assembly space by homogeneous transformation matrix. Automatic assembly of different functional fixture elements and auto-body part is implemented with API function based on the second development of UG. It is proven in practice that the method in this paper is feasible and high efficiency.

  13. A new data integration approach for AutoCAD and GIS

    NASA Astrophysics Data System (ADS)

    Ye, Hongmei; Li, Yuhong; Wang, Cheng; Li, Lijun

    2006-10-01

    GIS has its advantages both on spatial data analysis and management, particularly on the geometric and attributive information management, which has also attracted lots attentions among researchers around world. AutoCAD plays more and more important roles as one of the main data sources of GIS. Various work and achievements can be found in the related literature. However, the conventional data integration from AutoCAD to GIS is time-consuming, which also can cause the information loss both in the geometric aspects and the attributive aspects for a large system. It is necessary and urgent to sort out new approach and algorithm for the efficient high-quality data integration. In this paper, a novel data integration approach from AutoCAD to GIS will be introduced based on the spatial data mining technique through the data structure analysis both in the AutoCAD and GIS. A practicable algorithm for the data conversion from CAD to GIS will be given as well. By a designed evaluation scheme, the accuracy of the conversion both in the geometric and the attributive information will be demonstrated. Finally, the validity and feasibility of the new approach will be shown by an experimental analysis.

  14. The Resurgence of America's Auto Industry

    ScienceCinema

    Zimmer, Stephen; Cischke, Sue

    2018-05-01

    A look at how strategic investments and partnerships between the Energy Department and automakers have helped the American auto industry become a leader in advanced and fuel-efficient vehicles — creating jobs and boosting profits in the process.

  15. Auto Trade Policy and the Press: Auto Elite as a Source of the Media Agenda.

    ERIC Educational Resources Information Center

    Chang, Kuang-Kuo

    1999-01-01

    Contributes to scholarship on agenda setting and news reporting of international-trade issues. Uses content analysis to show that the auto elite set the agenda for the "New York Times" and the "Detroit News." Shows that the "Detroit News" was more likely than the "New York Times" to be more biased,…

  16. Auto Body Welding 2 (Course Outline), Automotive Body Repair and Refinishing 1: 9033.04.

    ERIC Educational Resources Information Center

    Dade County Public Schools, Miami, FL.

    The 90-hour course is a foundation quinmester course in welding for the auto body repairman. The outline consists of seven blocks of instruction (orientation, 6 hours; auto body oxyacetylene welding, 10 hours; electric arc welding equipment, 6 hours; auto body electric arc welding, 8 hours; position welding, 40 hours; electric spot welders, 16…

  17. Patterns of synchrony for feed-forward and auto-regulation feed-forward neural networks.

    PubMed

    Aguiar, Manuela A D; Dias, Ana Paula S; Ferreira, Flora

    2017-01-01

    We consider feed-forward and auto-regulation feed-forward neural (weighted) coupled cell networks. In feed-forward neural networks, cells are arranged in layers such that the cells of the first layer have empty input set and cells of each other layer receive only inputs from cells of the previous layer. An auto-regulation feed-forward neural coupled cell network is a feed-forward neural network where additionally some cells of the first layer have auto-regulation, that is, they have a self-loop. Given a network structure, a robust pattern of synchrony is a space defined in terms of equalities of cell coordinates that is flow-invariant for any coupled cell system (with additive input structure) associated with the network. In this paper, we describe the robust patterns of synchrony for feed-forward and auto-regulation feed-forward neural networks. Regarding feed-forward neural networks, we show that only cells in the same layer can synchronize. On the other hand, in the presence of auto-regulation, we prove that cells in different layers can synchronize in a robust way and we give a characterization of the possible patterns of synchrony that can occur for auto-regulation feed-forward neural networks.

  18. Practical Tests with the "auto Control Slot." Part II : Discussion

    NASA Technical Reports Server (NTRS)

    Lachmann, G

    1930-01-01

    For some time the D.V.L. has been investigating the question of applicability of Handley Page slotted wings to German airplanes. Comparitive gliding tests were made with open and closed slots on an Albatros L 75 airplane equipped with the Handley Page "auto control slots." This investigation served to determine the effect of the auto control slot on the properties and performances of airplanes at large angles of attack. The most important problems were whether the angle of glide at small angles of attack can be increased by the adoption of the auto control slot and, in particular, as to whether the flight characteristics at large angles of attack are improved thereby and equilibrium in gliding flight is guaranteed even at larger than ordinary angles of attack.

  19. Practical Tests with the "auto Control Slot." Part I : Lecture

    NASA Technical Reports Server (NTRS)

    Lachmann, G

    1930-01-01

    For some time the D.V.L. has been investigating the question of applicability of Handley Page slotted wings to German airplanes. Comparitive gliding tests were made with open and closed slots on an Albatros L 75 airplane equipped with the Handley Page "auto control slots." This investigation served to determine the effect of the auto control slot on the properties and performances of airplanes at large angles of attack. The most important problems were whether the angle of glide at small angles of attack can be increased by the adoption of the auto control slot and, in particular, as to whether the flight characteristics at large angles of attack are improved thereby and equilibrium in gliding flight is guaranteed even at larger than ordinary angles of attack.

  20. A voxel visualization and analysis system based on AutoCAD

    NASA Astrophysics Data System (ADS)

    Marschallinger, Robert

    1996-05-01

    A collection of AutoLISP programs is presented which enable the visualization and analysis of voxel models by AutoCAD rel. 12/rel. 13. The programs serve as an interactive, graphical front end for manipulating the results of three-dimensional modeling software producing block estimation data. ASCII data files describing geometry and attributes per estimation block are imported and stored as a voxel array. Each voxel may contain multiple attributes, therefore different parameters may be incorporated in one voxel array. Voxel classification is implemented on a layer basis providing flexible treatment of voxel classes such as recoloring, peeling, or volumetry. A versatile clipping tool enables slicing voxel arrays according to combinations of three perpendicular clipping planes. The programs feature an up-to-date, graphical user interface for user-friendly operation by non AutoCAD specialists.

  1. Auto-disable syringes for immunization: issues in technology transfer.

    PubMed Central

    Lloyd, J. S.; Milstien, J. B.

    1999-01-01

    WHO and its partners recommend the use of auto-disable syringes, "bundled" with the supply of vaccines when donor dollars are used, in all mass immunization campaigns, and also strongly advocate their use in routine immunization programmes. Because of the relatively high price of auto-disable syringes, WHO's Technical Network for Logistics in Health recommends that activities be initiated to encourage the transfer of production technology for these syringes as a means of promoting their use and enhancing access to the technology. The present article examines factors influencing technology transfer, including feasibility, corporate interest, cost, quality assurance, intellectual property considerations, and probable time frames for implementation. Technology transfer activities are likely to be complex and difficult, and may not result in lower prices for syringes. Guidelines are offered on technology transfer initiatives for auto-disable syringes to ensure the quality of the product, the reliability of the supply, and the feasibility of the technology transfer activity itself. PMID:10680248

  2. Clinical utility of anti-p53 auto-antibody: Systematic review and focus on colorectal cancer

    PubMed Central

    Suppiah, Aravind; Greenman, John

    2013-01-01

    Mutation of the p53 gene is a key event in the carcinogenesis of many different types of tumours. These can occur throughout the length of the p53 gene. Anti-p53 auto-antibodies are commonly produced in response to these p53 mutations. This review firstly describes the various mechanisms of p53 dysfunction and their association with subsequent carcinogenesis. Following this, the mechanisms of induction of anti-p53 auto-antibody production are shown, with various hypotheses for the discrepancies between the presence of p53 mutation and the presence/absence of anti-p53 auto-antibodies. A systematic review was performed with a descriptive summary of key findings of each anti-p53 auto-antibody study in all cancers published in the last 30 years. Using this, the cumulative frequency of anti-p53 auto-antibody in each cancer type is calculated and then compared with the incidence of p53 mutation in each cancer to provide the largest sample calculation and correlation between mutation and anti-p53 auto-antibody published to date. Finally, the review focuses on the data of anti-p53 auto-antibody in colorectal cancer studies, and discusses future strategies including the potentially promising role using anti-p53 auto-antibody presence in screening and surveillance. PMID:23922463

  3. The Potential of AutoClass as an Asteroidal Data Mining Tool

    NASA Astrophysics Data System (ADS)

    Walker, Matthew; Ziffer, J.; Harvell, T.; Fernandez, Y. R.; Campins, H.

    2011-05-01

    AutoClass-C, an artificial intelligence program designed to classify large data sets, was developed by NASA to classify stars based upon their infrared colors. Wanting to investigate its ability to classify asteroidal data, we conducted a preliminary test to determine if it could accurately reproduce the Tholen taxonomy using the data from the Eight Color Asteroid Survey (ECAS). For our initial test, we limited ourselves to those asteroids belonging to S, C, or X classes, and to asteroids with a color difference error of less than +/- 0.05 magnitudes. Of those 406 asteroids, AutoClass was able to confidently classify 85%: identifying the remaining asteroids as belonging to more than one class. Of the 346 asteroids that AutoClass classified, all but 3 (<1%) were classified as they had been in the Tholen classification scheme. Inspired by our initial success, we reran AutoClass, this time including IRAS albedos and limiting the asteroids to those that had also been observed and classified in the Bus taxonomy. Of those 258 objects, AutoClass was able to classify 248 with greater than 75% certainty, and ranked albedo, not color, as the most influential factor. Interestingly, AutoClass consistently put P type objects in with the C class (there were 19 P types and 7 X types mixed in with the other 154 C types), and omitted P types from the group associated with the other X types (which had only one rogue B type in with its other 49 X-types). Autoclass classified the remaining classes with a high accuracy: placing one A and one CU type in with an otherwise perfect S group; placing three P type and one T type in an otherwise perfect D group; and placing the four remaining asteroids (V, A, R, and Q) into a class together.

  4. AutoBayes Program Synthesis System System Internals

    NASA Technical Reports Server (NTRS)

    Schumann, Johann Martin

    2011-01-01

    This lecture combines the theoretical background of schema based program synthesis with the hands-on study of a powerful, open-source program synthesis system (Auto-Bayes). Schema-based program synthesis is a popular approach toward program synthesis. The lecture will provide an introduction into this topic and discuss how this technology can be used to generate customized algorithms. The synthesis of advanced numerical algorithms requires the availability of a powerful symbolic (algebra) system. Its task is to symbolically solve equations, simplify expressions, or to symbolically calculate derivatives (among others) such that the synthesized algorithms become as efficient as possible. We will discuss the use and importance of the symbolic system for synthesis. Any synthesis system is a large and complex piece of code. In this lecture, we will study Autobayes in detail. AutoBayes has been developed at NASA Ames and has been made open source. It takes a compact statistical specification and generates a customized data analysis algorithm (in C/C++) from it. AutoBayes is written in SWI Prolog and many concepts from rewriting, logic, functional, and symbolic programming. We will discuss the system architecture, the schema libary and the extensive support infra-structure. Practical hands-on experiments and exercises will enable the student to get insight into a realistic program synthesis system and provides knowledge to use, modify, and extend Autobayes.

  5. Controls for and constraints on auto-shaping

    PubMed Central

    Bilbrey, John; Winokur, Stephen

    1973-01-01

    Auto-shaping the pigeon's key-peck response was examined as a respondent conditioning procedure with the use of Rescorla's truly-random control procedure. In the first experiment, pigeons received presentations of brief light on the response key and brief presentations of food where the light and the food were independently presented. All birds failed to key peck after many light and food presentations, but explicit pairing of the light and food rapidly conditioned pecking to the light. Experiment 2 showed that even when an independent light/food presentation schedule was reduced to variable-time 30 sec, additional naive birds would not key peck and only one bird pecked when the schedules were variable-time 15 sec. A third experiment examined an explicit-unpairing control procedure, where the light and food were not only presented on independent schedules but were also separated by a minimum time, and found that auto-shaping did not occur. A fourth experiment investigated a number of control procedures and found them ineffective. A fifth experiment investigated the effects of a physical separation of the locus of the response key and the food dispenser, and a sixth experiment investigated using a tone in place of the light. It was concluded that pecking is generated by auto-shaping procedures only when an intermittently presented keylight is regularly paired with food. PMID:16811710

  6. Retrofitting the AutoBayes Program Synthesis System with Concrete Syntax

    NASA Technical Reports Server (NTRS)

    Fischer, Bernd; Visser, Eelco

    2004-01-01

    AutoBayes is a fully automatic, schema-based program synthesis system for statistical data analysis applications. Its core component is a schema library. i.e., a collection of generic code templates with associated applicability constraints which are instantiated in a problem-specific way during synthesis. Currently, AutoBayes is implemented in Prolog; the schemas thus use abstract syntax (i.e., Prolog terms) to formulate the templates. However, the conceptual distance between this abstract representation and the concrete syntax of the generated programs makes the schemas hard to create and maintain. In this paper we describe how AutoBayes is retrofitted with concrete syntax. We show how it is integrated into Prolog and describe how the seamless interaction of concrete syntax fragments with AutoBayes's remaining legacy meta-programming kernel based on abstract syntax is achieved. We apply the approach to gradually mitigate individual schemas without forcing a disruptive migration of the entire system to a different First experiences show that a smooth migration can be achieved. Moreover, it can result in a considerable reduction of the code size and improved readability of the code. In particular, abstracting out fresh-variable generation and second-order term construction allows the formulation of larger continuous fragments.

  7. Long-term outcome of patients with multiple [corrected] myeloma-related advanced renal failure following auto-SCT.

    PubMed

    Glavey, S V; Gertz, M A; Dispenzieri, A; Kumar, S; Buadi, F; Lacy, M; Hayman, S R; Kapoor, P; Dingli, D; McCurdy, A; Hogan, W J; Gastineau, D A; Leung, N

    2013-11-01

    Renal failure commonly complicates multiple myeloma (MM) and is associated with reduced survival. It is not clear whether auto-SCT results in improved renal function or attainment of independence from dialysis in patients with advanced renal impairment due to MM. We conducted a retrospective cohort study of all patients who underwent auto-SCT for MM complicated by advanced renal failure at our institution over a 10-year period (2000-2010). We aimed to assess the association between auto-SCT and renal outcome in patients with serum creatinine (SCr) over 3 mg/dL, attributable to MM, including those who were dialysis dependent. Thirty patients (2.8% of all auto-SCT patients) met inclusion criteria. Fourteen of 15 patients who were dialysis dependent before auto-SCT remained dialysis dependent in the long term despite hematological response (HR). Of the remaining 15 patients with SCr >3 mg/dL, an improvement in glomerular filtration rate (GFR) from 15 to 19.4 mL/min/1.73 m(2) was noted post auto-SCT (P=0.035); however, neither HR post auto-SCT or pre-existing renal function were independently associated with renal outcome. Auto-SCT was not associated with independence from dialysis in patients with renal failure due to MM at our institution. Although auto-SCT was associated with an improvement in GFR in patients with SCr >3 mg/dL, this improvement was not related to HR.

  8. Apprenticeship Training: Auto Body Technician Program.

    ERIC Educational Resources Information Center

    Alberta Learning, Edmonton. Apprenticeship and Industry Training.

    This document presents information about the apprenticeship training program of Alberta, Canada, in general and the auto body technician program in particular. The first part of the document discusses the following items: Alberta's apprenticeship and industry training system; the apprenticeship and industry training committee structure; local…

  9. Phenotypic modulation of auto-reactive cells by insertion of tolerogenic molecules via MSC-derived exosomes.

    PubMed

    Mokarizadeh, Aram; Delirezh, Nowruz; Morshedi, Ahhmad; Mosayebi, Ghasem; Farshid, Amir-Abbas; Dalir-Naghadeh, Bahram

    2012-01-01

    Auto-reactive cells-mediated immune responses are responsible for the current tissue damages during autoimmunity. Accordingly, functional modulation of auto-reactive cells has been a pivotal aim in many of recent studies. In the current study, we investigated the possibility for insertion of regulatory molecules onto auto-reactive cells through exosomal nano-shuttles as a novel approach for phenotype modification of auto-reactive cells. The exosomes were isolated from supernatant of mesenchymal stem cells culture. Resultant exosomes co-cultured with lymphocytes were harvested from established EAE mice in the presence of antigenic MOG35-55 peptide. After 24 hr, insertion of exosomal tolerogenic molecules (PD-L1, TGF-β, galectin-1) onto auto-reactive cells were explored through flow cytometry. The potency of exosomal inserted membrane molecules to modulate phenotype of auto-reactive lymphocytes was assessed upon ELISA test for their-derived cytokines IFN-γ and IL-17. Incorporation of exosomal molecules into lymohocytes' membrane was confirmed by flow cytometric analyses for surface levels of mentioned molecules. Additionally, the decreased secretion of IFN-γ and IL-17 were detected in exosome pre-treated lymphocytes upon stimulation with MOG peptide. Mesenchymal stem cells -derived exosomes showed to be efficient organelles for insertion of bioactive tolerogenic molecules onto auto-reactive cells and modulation of their phenotypes.

  10. Systemic and anti-neuronal auto-antibodies in patients with paraneoplastic neurological disease.

    PubMed

    Moll, J W; Hooijkaas, H; van Goorbergh, B C; Roos, L G; Henzen-Logmans, S C; Vecht, C J

    1996-01-01

    Sera from 23 patients with paraneoplastic disease of the central nervous system (PNS) were examined for the presence of anti-neuronal (anti-Hu, anti-Yo/PCA) and anti-Ri) and systemic auto-antibodies, including antibodies against DNA, centromeres, nRNP, Sm antigen, Scl-70, Ro(SS-A), La(SS-B), mitochondria, thyroid antigens, parietal calls, brush border antigen and rheumatoid factor. As controls, sera from 33 patients with small cell lung cancer, 33 with ovarian cancer and 7 with breast cancer and from 107 aged-matched healthy persons were used. Systemic auto-antibodies were found in 52% of patients with paraneoplastic neurological syndromes compared with only 16% (P = 0.001) in the control group with cancer only and 15% in the group of healthy controls. The relatively high percentage of systemic auto-antibodies in patients with PNS indicates that there is a genetic susceptibility to the development of auto-immune phenomena. This may provide an explanation for the relatively rare occurrence of PNS in patients with cancer.

  11. Anti-pentraxin 3 auto-antibodies might be protective in lupus nephritis: a large cohort study.

    PubMed

    Yuan, Mo; Tan, Ying; Pang, Yun; Li, Yong-Zhe; Song, Yan; Yu, Feng; Zhao, Ming-Hui

    2017-11-01

    Anti-pentraxin 3 (PTX3) auto-antibodies were found to be associated with the absence of renal involvement in systemic lupus erythematosus (SLE). This study is to investigate the prevalence of anti-PTX3 auto-antibodies and their clinical significance based on a large Chinese lupus nephritis cohort. One hundred and ninety-six active lupus nephritis patients, 150 SLE patients without clinical renal involvement, and 100 healthy controls were enrolled. Serum anti-PTX3 auto-antibodies and PTX3 levels were screened by enzyme-linked immunosorbent assay (ELISA). The associations between anti-PTX3 auto-antibodies and clinicopathological parameters in lupus nephritis were further analyzed. Anti-PTX3 auto-antibodies were less prevalent in active lupus nephritis patients compared with SLE without renal involvement (19.4% (38/196) versus 40.7% (61/150), p < .001). The serum levels of anti-PTX3 auto-antibodies were negatively correlated with proteinuria in lupus nephritis (r = -.143, p = .047). The levels of proteinuria, serum creatinine, and the prevalence of thrombotic microangiopathy were significantly higher in patients with higher PTX3 levels (≥3.207 ng/ml) and without anti-PTX3 auto-antibodies compared with patients with lower PTX3 levels (<3.207 ng/ml) and with anti-PTX3 auto-antibodies (4.79 (3.39-8.28) versus 3.95 (1.78-7.0), p = .03; 168.84 ± 153.63 versus 101.44 ± 47.36, p = .01; 34.1% (14/41) versus 0% (0/9), p = .04; respectively). Anti-PTX3 auto-antibodies were less prevalent in active lupus nephritis patients compared with SLE without renal involvement and associated with less severe renal damage, especially with the combined evaluation of serum PTX3 levels.

  12. Auto-Generated Semantic Processing Services

    NASA Technical Reports Server (NTRS)

    Davis, Rodney; Hupf, Greg

    2009-01-01

    Auto-Generated Semantic Processing (AGSP) Services is a suite of software tools for automated generation of other computer programs, denoted cross-platform semantic adapters, that support interoperability of computer-based communication systems that utilize a variety of both new and legacy communication software running in a variety of operating- system/computer-hardware combinations. AGSP has numerous potential uses in military, space-exploration, and other government applications as well as in commercial telecommunications. The cross-platform semantic adapters take advantage of common features of computer- based communication systems to enforce semantics, messaging protocols, and standards of processing of streams of binary data to ensure integrity of data and consistency of meaning among interoperating systems. The auto-generation aspect of AGSP Services reduces development time and effort by emphasizing specification and minimizing implementation: In effect, the design, building, and debugging of software for effecting conversions among complex communication protocols, custom device mappings, and unique data-manipulation algorithms is replaced with metadata specifications that map to an abstract platform-independent communications model. AGSP Services is modular and has been shown to be easily integrable into new and legacy NASA flight and ground communication systems.

  13. 46 CFR 35.20-45 - Use of Auto Pilot-T/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Use of Auto Pilot-T/ALL. 35.20-45 Section 35.20-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Navigation § 35.20-45 Use of Auto Pilot—T/ALL. Except as provided in 33 CFR 164.13, when the automatic pilot is used in: (a) Areas...

  14. 46 CFR 35.20-45 - Use of Auto Pilot-T/ALL.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false Use of Auto Pilot-T/ALL. 35.20-45 Section 35.20-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Navigation § 35.20-45 Use of Auto Pilot—T/ALL. Except as provided in 33 CFR 164.13, when the automatic pilot is used in: (a) Areas...

  15. 46 CFR 35.20-45 - Use of Auto Pilot-T/ALL.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Use of Auto Pilot-T/ALL. 35.20-45 Section 35.20-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Navigation § 35.20-45 Use of Auto Pilot—T/ALL. Except as provided in 33 CFR 164.13, when the automatic pilot is used in: (a) Areas...

  16. 46 CFR 35.20-45 - Use of Auto Pilot-T/ALL.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Use of Auto Pilot-T/ALL. 35.20-45 Section 35.20-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Navigation § 35.20-45 Use of Auto Pilot—T/ALL. Except as provided in 33 CFR 164.13, when the automatic pilot is used in: (a) Areas...

  17. 46 CFR 35.20-45 - Use of Auto Pilot-T/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Use of Auto Pilot-T/ALL. 35.20-45 Section 35.20-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Navigation § 35.20-45 Use of Auto Pilot—T/ALL. Except as provided in 33 CFR 164.13, when the automatic pilot is used in: (a) Areas...

  18. Auto-Regulatory RNA Editing Fine-Tunes mRNA Re-Coding and Complex Behaviour in Drosophila

    PubMed Central

    Savva, Yiannis A.; Jepson, James E.C; Sahin, Asli; Sugden, Arthur U.; Dorsky, Jacquelyn S.; Alpert, Lauren; Lawrence, Charles; Reenan, Robert A.

    2014-01-01

    Auto-regulatory feedback loops are a common molecular strategy used to optimize protein function. In Drosophila many mRNAs involved in neuro-transmission are re-coded at the RNA level by the RNA editing enzyme dADAR, leading to the incorporation of amino acids that are not directly encoded by the genome. dADAR also re-codes its own transcript, but the consequences of this auto-regulation in vivo are unclear. Here we show that hard-wiring or abolishing endogenous dADAR auto-regulation dramatically remodels the landscape of re-coding events in a site-specific manner. These molecular phenotypes correlate with altered localization of dADAR within the nuclear compartment. Furthermore, auto-editing exhibits sexually dimorphic patterns of spatial regulation and can be modified by abiotic environmental factors. Finally, we demonstrate that modifying dAdar auto-editing affects adaptive complex behaviors. Our results reveal the in vivo relevance of auto-regulatory control over post-transcriptional mRNA re-coding events in fine-tuning brain function and organismal behavior. PMID:22531175

  19. Auto-Restricted Zone Demonstration in Memphis, TN

    DOT National Transportation Integrated Search

    1988-03-01

    The Service and Methods Demonstration conducted in downtown Memphis was one of 4 parallel demonstrations involving downtown auto-restricted zones (ARZs). Unlike the other three demonstrations (Boston, New York, and Providence), the Memphis ARZ was al...

  20. A Needs Assessment of Entry-Level Competencies for Modification of an Auto Body Repair Curriculum.

    ERIC Educational Resources Information Center

    Borremans, Robert T.

    A needs assessment was conducted to determine job tasks relevant for entry-level auto body repairers as a basis for updating the Auto Body Program at Blackhawk Technical Institute (BTI). A survey was mailed to 86 local auto body shops, asking employers to rank 149 tasks in 11 duty areas in terms of importance and frequency performed. Study…

  1. Fast radio burst search: cross spectrum vs. auto spectrum method

    NASA Astrophysics Data System (ADS)

    Liu, Lei; Zheng, Weimin; Yan, Zhen; Zhang, Juan

    2018-06-01

    The search for fast radio bursts (FRBs) is a hot topic in current radio astronomy studies. In this work, we carry out a single pulse search with a very long baseline interferometry (VLBI) pulsar observation data set using both auto spectrum and cross spectrum search methods. The cross spectrum method, first proposed in Liu et al., maximizes the signal power by fully utilizing the fringe phase information of the baseline cross spectrum. The auto spectrum search method is based on the popular pulsar software package PRESTO, which extracts single pulses from the auto spectrum of each station. According to our comparison, the cross spectrum method is able to enhance the signal power and therefore extract single pulses from data contaminated by high levels of radio frequency interference (RFI), which makes it possible to carry out a search for FRBs in regular VLBI observations when RFI is present.

  2. Age and genetic selection affect auto-immune profiles of chickens.

    PubMed

    Parmentier, Henk K; Harms, Elmer; Lammers, Aart; Nieuwland, Mike G B

    2014-12-01

    Specificity, antibody isotype distribution and levels, of natural autoantibodies (NAAb) may be potential informative parameters for immune mediated natural disease resistance, immune modulation, and maintenance of physiological homeostasis. In a previous study we detected IgM and IgG antibodies to liver antigens in plasma from 1 year old chickens. Auto-immune profiles directed towards liver antigens differed between chicken lines divergently selected for specific antibody responses to sheep red blood cells. In the present study we measured the presence and typed levels and antibody isotypes (IgG and IgM) of NAAb binding the 'auto-antigen' complex chicken liver cell lysate (CLL) in plasma samples obtained from chickens at 5 weeks and at 1-year of age, respectively, by quantitative western blotting. Extensive staining patterns of plasma antibodies binding CLL were found for both isotypes and at both ages in all birds. At both ages, IgM and IgG bound similar numbers of CLL antigens, which remained almost constant for IgM, whereas the number of IgG stained bands in time was enhanced. Significant differences of binding patterns of NAAb (stained antigen fragments of CLL and staining intensity) were detected between the three different chicken lines at both ages and between both ages, and lines could be clustered on the basis of their auto-antibody profile. The present results indicate that analysis of the plasma NAAb repertoire of poultry like in mammals could provide a way of distinguishing differences of immune competence (as reflected by the selection criterion of antibody responses) between individuals and lines, and could provide tools to select individual birds for health and other traits. The age-dependency of the auto-immune profile suggest that such profiles may also reflect immune maturation, which should be taken into account when relating an auto-immune profile with other traits. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Auto Code Generation for Simulink-Based Attitude Determination Control System

    NASA Technical Reports Server (NTRS)

    MolinaFraticelli, Jose Carlos

    2012-01-01

    This paper details the work done to auto generate C code from a Simulink-Based Attitude Determination Control System (ADCS) to be used in target platforms. NASA Marshall Engineers have developed an ADCS Simulink simulation to be used as a component for the flight software of a satellite. This generated code can be used for carrying out Hardware in the loop testing of components for a satellite in a convenient manner with easily tunable parameters. Due to the nature of the embedded hardware components such as microcontrollers, this simulation code cannot be used directly, as it is, on the target platform and must first be converted into C code; this process is known as auto code generation. In order to generate C code from this simulation; it must be modified to follow specific standards set in place by the auto code generation process. Some of these modifications include changing certain simulation models into their atomic representations which can bring new complications into the simulation. The execution order of these models can change based on these modifications. Great care must be taken in order to maintain a working simulation that can also be used for auto code generation. After modifying the ADCS simulation for the auto code generation process, it is shown that the difference between the output data of the former and that of the latter is between acceptable bounds. Thus, it can be said that the process is a success since all the output requirements are met. Based on these results, it can be argued that this generated C code can be effectively used by any desired platform as long as it follows the specific memory requirements established in the Simulink Model.

  4. Auto-induction for high level production of biologically active reteplase in Escherichia coli.

    PubMed

    Fathi-Roudsari, Mehrnoosh; Maghsoudi, Nader; Maghsoudi, Amirhossein; Niazi, Sepideh; Soleiman, Morvarid

    2018-06-07

    Reteplase is a third generation tissue plasminogen activator (tPA) with a modified structure and prolonged half-life in comparison to native tPA. As a non-glycosylated protein, reteplase is expressed in Escherichia coli. Due to presence of several disulfide bonds, high level production of reteplase is complicated and needs extra steps for conversion to biologically active form. Auto-induction represents a method for high-yield growth of bacterial cells and higher expression of recombinant proteins. Here we have tried to optimize the auto-induction procedure for soluble and active expression of reteplase in E. coli. Results showed that using auto-induction strategy at 37 °C, Rosetta-gami (DE3) had the highest level of active and soluble reteplase production in comparison to E. coli strains BL21 (DE3), and Shuffel T7. Temperature dominantly affected the level of active reteplase production. Decreasing the temperature to 25 and 18 °C increased the level of active reteplase by 20 and 60%, respectively. The composition of auto-induction medium also dramatically changed the active production of reteplase in cytoplasm. Using higher enriched auto-induction medium, super broth base including trace elements, significantly increased biologically active reteplase by 30%. It is demonstrated here that auto-induction is a powerful method for expression of biologically active reteplase in oxidative cytoplasm of Rosetta-gami. Optimizing expression condition by decreasing temperature and using an enriched auto-induction medium resulted in at least three times higher level of active reteplase production. Production of correctly folded and active reteplase in spite of its complex structure helps for removal of inefficient and cumbersome step of refolding. Copyright © 2018. Published by Elsevier Inc.

  5. Evaluation of autoCPAP devices in home treatment of sleep apnea/hypopnea syndrome.

    PubMed

    Meurice, J C; Cornette, A; Philip-Joet, F; Pepin, J L; Escourrou, P; Ingrand, P; Veale, D

    2007-11-01

    Quality of life (QOL) and sleepiness for patients with sleep apnea/hypopnea syndrome (SAHS) might improve with continuous positive airway pressure devices working in auto-adjust mode (autoCPAP) by allowing pressure modulations following patient needs. Clinical comparisons between devices driven by different algorithms are needed. We compared the clinical effectiveness of fixed pressure CPAP and four different autoCPAP devices by assessing compliance and QOL (36-item short-form health survey [SF-36]). SAHS patients were randomly allocated to five groups. Polysomnography (PSG) was performed to titrate the effective pressure in the constant CPAP group and evaluate residual apnea/hypopnea index (AHI) under autoCPAP. Follow-up consisted of clinical visits at three and six months by homecare technicians who assessed compliance, symptom scores and SF-36 scores. A laboratory-based PSG using the same CPAP/autoCPAP device as at home was performed at six months. Eighty-three patients (mean age 56+/-10 yrs) with mean body mass index (BMI) 30.8+/-5.3 kg/m(2) and severe SAHS (mean AHI: 52.3+/-17.8/h) were included. There were no differences in clinical symptoms or QOL scores, and similar clinical and PSG improvements were seen in all groups. CPAP use was >5 h per night, without any significant difference between groups. AutoCPAP is equally as effective as fixed CPAP for long-term home treatment in severe SAHS patients.

  6. Evaluation of auto incident recording system (AIRS).

    DOT National Transportation Integrated Search

    2005-05-01

    The Auto Incident Recording System (AIRS) is a sound-actuated video recording system. It automatically records potential incidents when activated by sound (horns, clashing metal, squealing tires, etc.). The purpose is to detect patterns of crashes at...

  7. Auto Mechanics. Volume II. Instructional Units.

    ERIC Educational Resources Information Center

    Armstrong, Ivan J.

    To assist teachers and students in understanding the latest concepts and functions of the automobile, this curriculum guide treats both the skills and knowledge necessary for auto mechanics. Developed by an advisory committee of instructors and mechanics in the industry, this manual consists of the following four sections: engine rebuilding;…

  8. A deep auto-encoder model for gene expression prediction.

    PubMed

    Xie, Rui; Wen, Jia; Quitadamo, Andrew; Cheng, Jianlin; Shi, Xinghua

    2017-11-17

    Gene expression is a key intermediate level that genotypes lead to a particular trait. Gene expression is affected by various factors including genotypes of genetic variants. With an aim of delineating the genetic impact on gene expression, we build a deep auto-encoder model to assess how good genetic variants will contribute to gene expression changes. This new deep learning model is a regression-based predictive model based on the MultiLayer Perceptron and Stacked Denoising Auto-encoder (MLP-SAE). The model is trained using a stacked denoising auto-encoder for feature selection and a multilayer perceptron framework for backpropagation. We further improve the model by introducing dropout to prevent overfitting and improve performance. To demonstrate the usage of this model, we apply MLP-SAE to a real genomic datasets with genotypes and gene expression profiles measured in yeast. Our results show that the MLP-SAE model with dropout outperforms other models including Lasso, Random Forests and the MLP-SAE model without dropout. Using the MLP-SAE model with dropout, we show that gene expression quantifications predicted by the model solely based on genotypes, align well with true gene expression patterns. We provide a deep auto-encoder model for predicting gene expression from SNP genotypes. This study demonstrates that deep learning is appropriate for tackling another genomic problem, i.e., building predictive models to understand genotypes' contribution to gene expression. With the emerging availability of richer genomic data, we anticipate that deep learning models play a bigger role in modeling and interpreting genomics.

  9. Auto-inhibition and phosphorylation-induced activation of PLC-γ isozymes

    PubMed Central

    Hajicek, Nicole; Charpentier, Thomas H.; Rush, Jeremy R.; Harden, T. Kendall; Sondek, John

    2013-01-01

    Multiple extracellular stimuli, such as growth factors and antigens, initiate signaling cascades through tyrosine phosphorylation and activation of phospholipase C (PLC)-γ isozymes. Like most other PLCs, PLC-γ1 is basally auto-inhibited by its X-Y linker, which separates the X-and Y-boxes of the catalytic core. The C-terminal SH2 (cSH2) domain within the X-Y linker is the critical determinant for auto-inhibition of phospholipase activity. Release of auto-inhibition requires an intramolecular interaction between the cSH2 domain and a phosphorylated tyrosine, Tyr783, also located within the X-Y linker. The molecular mechanisms that mediate auto-inhibition and phosphorylation-induced activation have not been defined. Here, we describe structures of the cSH2 domain both alone and bound to a PLC-γ1 peptide encompassing phosphorylated Tyr783. The cSH2 domain remains largely unaltered by peptide engagement. Point mutations in the cSH2 domain located at the interface with the peptide were sufficient to constitutively activate PLC-γ1 suggesting that peptide engagement directly interferes with the capacity of the cSH2 domain to block the lipase active site. This idea is supported by mutations in a complimentary surface of the catalytic core that also enhanced phospholipase activity. PMID:23777354

  10. Auto-trilevel versus bilevel positive airway pressure ventilation for hypercapnic overlap syndrome patients.

    PubMed

    Su, Mei; Huai, De; Cao, Juan; Ning, Ding; Xue, Rong; Xu, Meijie; Huang, Mao; Zhang, Xilong

    2018-03-01

    Although bilevel positive airway pressure (Bilevel PAP) therapy is usually used for overlap syndrome (OS), there is still a portion of OS patients in whom Bilevel PAP therapy could not simultaneously eliminate residual apnea events and hypercapnia. The current study was expected to explore whether auto-trilevel positive airway pressure (auto-trilevel PAP) therapy with auto-adjusting end expiratory positive airway pressure (EEPAP) can serve as a better alternative for these patients. From January of 2014 to June of 2016, 32 hypercapnic OS patients with stable chronic obstructive pulmonary diseases (COPD) and moderate-to-severe obstructive sleep apnea syndrome (OSAS) were recruited. Three variable modes of positive airway pressure (PAP) from the ventilator (Prisma25ST, Weinmann Inc., Germany) were applicated for 8 h per night. We performed the design of each mode at each night with an interval of two nights with no PAP treatment as a washout period among different modes. In Bilevel-1 mode (Bilevel-1), the expiratory positive airway pressure (EPAP) delivered from Bilevel PAP was always set as the lowest PAP for abolishment of snoring. For each patient, the inspiratory positive airway pressure (IPAP) was constantly set the same as the minimal pressure for keeping end-tidal CO 2 (ETCO 2 ) ≤45 mmHg for all three modes. However, the EPAP issued by Bilevel PAP in Bilevel-2 mode (Bilevel-2) was kept 3 cmH 2 O higher than that in Bilevel-1. In auto-trilevel mode (auto-trilevel) with auto-trilevel PAP, the initial part of EPAP was fixed at the same PAP as that in Bilevel-1 while the EEPAP was automatically regulated to rise at a range of ≤4 cmH 2 O based on nasal airflow wave changes. Comparisons were made for parameters before and during or following treatment as well as among different PAP therapy modes. The following parameters were compared such as nocturnal apnea hypopnea index (AHI), minimal SpO 2 (minSpO 2 ), arousal index, sleep structure and efficiency

  11. Clinical assessment of auto-positive end-expiratory pressure by diaphragmatic electrical activity during pressure support and neurally adjusted ventilatory assist.

    PubMed

    Bellani, Giacomo; Coppadoro, Andrea; Patroniti, Nicolò; Turella, Marta; Arrigoni Marocco, Stefano; Grasselli, Giacomo; Mauri, Tommaso; Pesenti, Antonio

    2014-09-01

    Auto-positive end-expiratory pressure (auto-PEEP) may substantially increase the inspiratory effort during assisted mechanical ventilation. Purpose of this study was to assess whether the electrical activity of the diaphragm (EAdi) signal can be reliably used to estimate auto-PEEP in patients undergoing pressure support ventilation and neurally adjusted ventilatory assist (NAVA) and whether NAVA was beneficial in comparison with pressure support ventilation in patients affected by auto-PEEP. In 10 patients with a clinical suspicion of auto-PEEP, the authors simultaneously recorded EAdi, airway, esophageal pressure, and flow during pressure support and NAVA, whereas external PEEP was increased from 2 to 14 cm H2O. Tracings were analyzed to measure apparent "dynamic" auto-PEEP (decrease in esophageal pressure to generate inspiratory flow), auto-EAdi (EAdi value at the onset of inspiratory flow), and IDEAdi (inspiratory delay between the onset of EAdi and the inspiratory flow). The pressure necessary to overcome auto-PEEP, auto-EAdi, and IDEAdi was significantly lower in NAVA as compared with pressure support ventilation, decreased with increase in external PEEP, although the effect of external PEEP was less pronounced in NAVA. Both auto-EAdi and IDEAdi were tightly correlated with auto-PEEP (r = 0.94 and r = 0.75, respectively). In the presence of auto-PEEP at lower external PEEP levels, NAVA was characterized by a characteristic shape of the airway pressure. In patients with auto-PEEP, NAVA, compared with pressure support ventilation, led to a decrease in the pressure necessary to overcome auto-PEEP, which could be reliably monitored by the electrical activity of the diaphragm before inspiratory flow onset (auto-EAdi).

  12. 75 FR 65524 - United Auto Workers Local 1999, Oklahoma City, OK; Notice of Negative Determination Regarding...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-25

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-71,863] United Auto Workers Local... workers and former workers of United Auto Workers Local 1999, Oklahoma City, Oklahoma (the subject firm... Auto Workers Local 1999, Oklahoma City, Oklahoma, was based on the findings that the workers at the...

  13. Auto Mechanics, Volume 1. Instructional Units.

    ERIC Educational Resources Information Center

    Armstrong, Ivan J.

    To assist teachers and students in understanding the latest concepts and functions of the automobile, this curriculum guide treats both the skills and knowledge necessary for auto mechanics. Developed by an advisory committee of instructors and mechanics in the industry, this manual consists of the following five sections: orientation and safety;…

  14. Auto Body Repair 103, 203, 303.

    ERIC Educational Resources Information Center

    Manitoba Dept. of Education, Winnipeg.

    As part of the high school vocational industrial program in Manitoba, this course has been designed to provide students with the foundation for a career in auto-body repair. The program introduces and provides opportunities for student skill development in the theories and techniques of tool and equipment operation, metallurgy and welding, damage…

  15. Fermi-Pasta-Ulam auto recurrence in the description of the electrical activity of the heart.

    PubMed

    Novopashin, M A; Shmid, A V; Berezin, A A

    2017-04-01

    The authors proposed and mathematically described model of a new type of the Fermi-Pasta-Ulam recurrence (the FPU auto recurrence) and hypothesized an adequate description of the heart's electrical dynamics within the observed phenomenon. The dynamics of the FPU auto recurrence making appropriate electrical dynamics of the normal functioning of the heart in the form of an electrocardiogram (ECG) was obtained by a computer model study. The model solutions in the form of the FPU auto recurrence - ECG Fourier spectrum were evaluated for resistance to external disturbances in the form of random effects, as well as periodic perturbation at a frequency close to the heart beating rate of about 1Hz. In addition, in order to simulate the dynamics of myocardial infarction model, studied the effect of the surface area of the myocardium on the stability and shape of the auto recurrence - ECG spectrum. It has been found that the intense external disturbing periodic impacts at a frequency of about 1Hz lead to a sharp disturbance spectrum shape FPU auto recurrence - ECG structure. In addition, the decrease in the surface of the myocardium by 50% in the model led to the destruction of structures of the auto recurrence - ECG, which corresponds to the state of atrial myocardium. Research models have revealed a hypothetical basis of coronary heart disease in the form of increasing the energy of high-frequency harmonics spectrum of the auto recurrence by reducing the energy of low-frequency harmonic spectrum of the auto recurrence, which ultimately leads to a sharp decrease in myocardial contractility. In order to test the hypothesis has been studied more than 20,000 ECGs both healthy people and patients with cardiovascular disease. As a result of these studies, it was found that the dynamics of the electrical activity of normal functioning of the heart can be interpreted by the display of the detected by authors the FPU auto recurrence, and coronary heart disease is a violation of

  16. Complement deposition induced by binding of anti-contactin-1 auto-antibodies is modified by immunoglobulins.

    PubMed

    Appeltshauser, Luise; Weishaupt, Andreas; Sommer, Claudia; Doppler, Kathrin

    2017-01-01

    Inflammatory neuropathies associated with auto-antibodies against paranodal proteins like contactin-1 are reported to respond poorly to treatment with intravenous immunoglobulins (IVIG). A reason might be that IVIG interacts with the complement pathway and these auto-antibodies often belong to the IgG4 subclass that does not activate complement. However, some patients do show a response to IVIG, especially at the beginning of the disease. This corresponds with the finding of coexisting IgG subclasses IgG1, IgG2 and IgG3. We therefore aimed to investigate complement deposition and activation by samples of three patients with anti-contactin-1 IgG auto-antibodies of different subclasses as a potential predictor for response to IVIG. Complement deposition and activation was measured by cell binding and ELISA based assays, and the effect of IVIG on complement deposition was assessed by addition of different concentrations of IVIG. Binding of anti-contactin-1 auto-antibodies of all three patients induced complement deposition and activation with the strongest effect shown by the serum of a patient with predominance of IgG3 auto-antibodies. IVIG led to a reduction of complement deposition in a dose-dependent manner, but did not reduce binding of auto-antibodies to contactin-1. We conclude that complement deposition may contribute to the pathophysiology of anti-contactin-1 associated neuropathy, particularly in patients with predominance of the IgG3 subclass. The proportion of different auto-antibody subclasses may be a predictor for the response to IVIG in patients with auto-antibodies against paranodal proteins. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. AutoBD: Automated Bi-Level Description for Scalable Fine-Grained Visual Categorization.

    PubMed

    Yao, Hantao; Zhang, Shiliang; Yan, Chenggang; Zhang, Yongdong; Li, Jintao; Tian, Qi

    Compared with traditional image classification, fine-grained visual categorization is a more challenging task, because it targets to classify objects belonging to the same species, e.g. , classify hundreds of birds or cars. In the past several years, researchers have made many achievements on this topic. However, most of them are heavily dependent on the artificial annotations, e.g., bounding boxes, part annotations, and so on . The requirement of artificial annotations largely hinders the scalability and application. Motivated to release such dependence, this paper proposes a robust and discriminative visual description named Automated Bi-level Description (AutoBD). "Bi-level" denotes two complementary part-level and object-level visual descriptions, respectively. AutoBD is "automated," because it only requires the image-level labels of training images and does not need any annotations for testing images. Compared with the part annotations labeled by the human, the image-level labels can be easily acquired, which thus makes AutoBD suitable for large-scale visual categorization. Specifically, the part-level description is extracted by identifying the local region saliently representing the visual distinctiveness. The object-level description is extracted from object bounding boxes generated with a co-localization algorithm. Although only using the image-level labels, AutoBD outperforms the recent studies on two public benchmark, i.e. , classification accuracy achieves 81.6% on CUB-200-2011 and 88.9% on Car-196, respectively. On the large-scale Birdsnap data set, AutoBD achieves the accuracy of 68%, which is currently the best performance to the best of our knowledge.Compared with traditional image classification, fine-grained visual categorization is a more challenging task, because it targets to classify objects belonging to the same species, e.g. , classify hundreds of birds or cars. In the past several years, researchers have made many achievements on this topic

  18. A dedicated on-line detecting system for auto air dryers

    NASA Astrophysics Data System (ADS)

    Shi, Chao-yu; Luo, Zai

    2013-10-01

    According to the correlative automobile industry standard and the requirements of manufacturer, this dedicated on-line detecting system is designed against the shortage of low degree automatic efficiency and detection precision of auto air dryer in the domestic. Fast automatic detection is achieved by combining the technology of computer control, mechatronics and pneumatics. This system can detect the speciality performance of pressure regulating valve and sealability of auto air dryer, in which online analytical processing of test data is available, at the same time, saving and inquiring data is achieved. Through some experimental analysis, it is indicated that efficient and accurate detection of the performance of auto air dryer is realized, and the test errors are less than 3%. Moreover, we carry out the type A evaluation of uncertainty in test data based on Bayesian theory, and the results show that the test uncertainties of all performance parameters are less than 0.5kPa, which can meet the requirements of operating industrial site absolutely.

  19. Sensor-based auto-focusing system using multi-scale feature extraction and phase correlation matching.

    PubMed

    Jang, Jinbeum; Yoo, Yoonjong; Kim, Jongheon; Paik, Joonki

    2015-03-10

    This paper presents a novel auto-focusing system based on a CMOS sensor containing pixels with different phases. Robust extraction of features in a severely defocused image is the fundamental problem of a phase-difference auto-focusing system. In order to solve this problem, a multi-resolution feature extraction algorithm is proposed. Given the extracted features, the proposed auto-focusing system can provide the ideal focusing position using phase correlation matching. The proposed auto-focusing (AF) algorithm consists of four steps: (i) acquisition of left and right images using AF points in the region-of-interest; (ii) feature extraction in the left image under low illumination and out-of-focus blur; (iii) the generation of two feature images using the phase difference between the left and right images; and (iv) estimation of the phase shifting vector using phase correlation matching. Since the proposed system accurately estimates the phase difference in the out-of-focus blurred image under low illumination, it can provide faster, more robust auto focusing than existing systems.

  20. Sensor-Based Auto-Focusing System Using Multi-Scale Feature Extraction and Phase Correlation Matching

    PubMed Central

    Jang, Jinbeum; Yoo, Yoonjong; Kim, Jongheon; Paik, Joonki

    2015-01-01

    This paper presents a novel auto-focusing system based on a CMOS sensor containing pixels with different phases. Robust extraction of features in a severely defocused image is the fundamental problem of a phase-difference auto-focusing system. In order to solve this problem, a multi-resolution feature extraction algorithm is proposed. Given the extracted features, the proposed auto-focusing system can provide the ideal focusing position using phase correlation matching. The proposed auto-focusing (AF) algorithm consists of four steps: (i) acquisition of left and right images using AF points in the region-of-interest; (ii) feature extraction in the left image under low illumination and out-of-focus blur; (iii) the generation of two feature images using the phase difference between the left and right images; and (iv) estimation of the phase shifting vector using phase correlation matching. Since the proposed system accurately estimates the phase difference in the out-of-focus blurred image under low illumination, it can provide faster, more robust auto focusing than existing systems. PMID:25763645

  1. Auto-SCT improves survival in systemic light chain amyloidosis: a retrospective analysis with 14-year follow-up.

    PubMed

    Parmar, S; Kongtim, P; Champlin, R; Dinh, Y; Elgharably, Y; Wang, M; Bashir, Q; Shah, J J; Shah, N; Popat, U; Giralt, S A; Orlowski, R Z; Qazilbash, M H

    2014-08-01

    Optimal treatment approach continues to remain a challenge for systemic light chain amyloidosis (AL). So far, Auto-SCT is the only modality associated with long-term survival. However, failure to show survival benefit in randomized study raises questions regarding its efficacy. We present a comparative outcome analysis of Auto-SCT to conventional therapies (CTR) in AL patients treated over a 14-year period at our institution. Out of the 145 AL amyloidosis patients, Auto-SCT was performed in 80 patients with 1-year non-relapse mortality rate of 12.5%. Novel agents were used as part of induction therapy in 56% of transplant recipients vs 46% of CTR patients. Hematological and organ responses were seen in 74.6% and 39% in the Auto-SCT arm vs 53% and 12% in the CTR arm, respectively. The projected 5-year survival for Auto-SCT vs CTR was 63% vs 38%, respectively. Landmark analysis of patients alive at 1-year after diagnosis showed improved 5-year OS of 72% with Auto-SCT vs 65% in the CTR arm. In the multivariate analysis, age <60 years, induction therapy with novel agents, kidney only involvement and Auto-SCT were associated with improved survival. In conclusion, Auto-SCT is associated with long-term survival for patients with AL amyloidosis.

  2. Auto-Context Convolutional Neural Network (Auto-Net) for Brain Extraction in Magnetic Resonance Imaging.

    PubMed

    Mohseni Salehi, Seyed Sadegh; Erdogmus, Deniz; Gholipour, Ali

    2017-11-01

    Brain extraction or whole brain segmentation is an important first step in many of the neuroimage analysis pipelines. The accuracy and the robustness of brain extraction, therefore, are crucial for the accuracy of the entire brain analysis process. The state-of-the-art brain extraction techniques rely heavily on the accuracy of alignment or registration between brain atlases and query brain anatomy, and/or make assumptions about the image geometry, and therefore have limited success when these assumptions do not hold or image registration fails. With the aim of designing an accurate, learning-based, geometry-independent, and registration-free brain extraction tool, in this paper, we present a technique based on an auto-context convolutional neural network (CNN), in which intrinsic local and global image features are learned through 2-D patches of different window sizes. We consider two different architectures: 1) a voxelwise approach based on three parallel 2-D convolutional pathways for three different directions (axial, coronal, and sagittal) that implicitly learn 3-D image information without the need for computationally expensive 3-D convolutions and 2) a fully convolutional network based on the U-net architecture. Posterior probability maps generated by the networks are used iteratively as context information along with the original image patches to learn the local shape and connectedness of the brain to extract it from non-brain tissue. The brain extraction results we have obtained from our CNNs are superior to the recently reported results in the literature on two publicly available benchmark data sets, namely, LPBA40 and OASIS, in which we obtained the Dice overlap coefficients of 97.73% and 97.62%, respectively. Significant improvement was achieved via our auto-context algorithm. Furthermore, we evaluated the performance of our algorithm in the challenging problem of extracting arbitrarily oriented fetal brains in reconstructed fetal brain magnetic

  3. Estimates of Average Glandular Dose with Auto-modes of X-ray Exposures in Digital Breast Tomosynthesis.

    PubMed

    Kamal, Izdihar; Chelliah, Kanaga K; Mustafa, Nawal

    2015-05-01

    The aim of this research was to examine the average glandular dose (AGD) of radiation among different breast compositions of glandular and adipose tissue with auto-modes of exposure factor selection in digital breast tomosynthesis. This experimental study was carried out in the National Cancer Society, Kuala Lumpur, Malaysia, between February 2012 and February 2013 using a tomosynthesis digital mammography X-ray machine. The entrance surface air kerma and the half-value layer were determined using a 100H thermoluminescent dosimeter on 50% glandular and 50% adipose tissue (50/50) and 20% glandular and 80% adipose tissue (20/80) commercially available breast phantoms (Computerized Imaging Reference Systems, Inc., Norfolk, Virginia, USA) with auto-time, auto-filter and auto-kilovolt modes. The lowest AGD for the 20/80 phantom with auto-time was 2.28 milliGray (mGy) for two dimension (2D) and 2.48 mGy for three dimensional (3D) images. The lowest AGD for the 50/50 phantom with auto-time was 0.97 mGy for 2D and 1.0 mGy for 3D. The AGD values for both phantoms were lower against a high kilovolt peak and the use of auto-filter mode was more practical for quick acquisition while limiting the probability of operator error.

  4. Auto-ubiquitination of Mdm2 Enhances Its Substrate Ubiquitin Ligase Activity*

    PubMed Central

    Ranaweera, Ruchira S.; Yang, Xiaolu

    2013-01-01

    The RING domain E3 ubiquitin ligase Mdm2 is the master regulator of the tumor suppressor p53. It targets p53 for proteasomal degradation, restraining the potent activity of p53 and enabling cell survival and proliferation. Like most E3 ligases, Mdm2 can also ubiquitinate itself. How Mdm2 auto-ubiquitination may influence its substrate ubiquitin ligase activity is undefined. Here we show that auto-ubiquitination of Mdm2 is an activating event. Mdm2 that has been conjugated to polyubiquitin chains, but not to single ubiquitins, exhibits substantially enhanced activity to polyubiquitinate p53. Mechanistically, auto-ubiquitination of Mdm2 facilitates the recruitment of the E2 ubiquitin-conjugating enzyme. This occurs through noncovalent interactions between the ubiquitin chains on Mdm2 and the ubiquitin binding domain on E2s. Mutations that diminish the noncovalent interactions render auto-ubiquitination unable to stimulate Mdm2 substrate E3 activity. These results suggest a model in which polyubiquitin chains on an E3 increase the local concentration of E2 enzymes and permit the processivity of substrate ubiquitination. They also support the notion that autocatalysis may be a prevalent mode for turning on the activity of latent enzymes. PMID:23671280

  5. Fault tolerant control of multivariable processes using auto-tuning PID controller.

    PubMed

    Yu, Ding-Li; Chang, T K; Yu, Ding-Wen

    2005-02-01

    Fault tolerant control of dynamic processes is investigated in this paper using an auto-tuning PID controller. A fault tolerant control scheme is proposed composing an auto-tuning PID controller based on an adaptive neural network model. The model is trained online using the extended Kalman filter (EKF) algorithm to learn system post-fault dynamics. Based on this model, the PID controller adjusts its parameters to compensate the effects of the faults, so that the control performance is recovered from degradation. The auto-tuning algorithm for the PID controller is derived with the Lyapunov method and therefore, the model predicted tracking error is guaranteed to converge asymptotically. The method is applied to a simulated two-input two-output continuous stirred tank reactor (CSTR) with various faults, which demonstrate the applicability of the developed scheme to industrial processes.

  6. Identifying Potential Ventilator Auto-Triggering Among Organ Procurement Organization Referrals.

    PubMed

    Henry, Nicholas R; Russian, Christopher J; Nespral, Joseph

    2016-06-01

    Ventilator auto-trigger is the delivery of an assisted mechanical ventilated breath over the set ventilator frequency in the absence of a spontaneous inspiratory effort and can be caused by inappropriate ventilator trigger sensitivity. Ventilator auto-trigger can be misinterpreted as a spontaneous breath and has the potential to delay or prevent brain death testing and confuse health-care professionals and/or patient families. To determine the frequency of organ donor referrals from 1 Organ Procurement Organization (OPO) that could benefit from an algorithm designed to assist organ recovery coordinators to identify and correct ventilator auto-triggering. This retrospective analysis evaluated documentation of organ donor referrals from 1 OPO in central Texas during the 2013 calendar year that resulted in the withdrawal of care by the patient's family and the recovery of organs. The frequency of referrals that presented with absent brain stem reflexes except for additional respirations over the set ventilator rate was determined to assess for the need of the proposed algorithm. Documentation of 672 organ procurement organization referrals was evaluated. Documentation from 42 referrals that resulted in the withdrawal of care and 21 referrals that resulted in the recovery of organs were identified with absent brain stem reflexes except for spontaneous respirations on the mechanical ventilator. As a result, an algorithm designed to identify and correct ventilator auto-trigger could have been used 63 times during the 2013 calendar year. © 2016, NATCO.

  7. Auto Mechanics Series. Duty Task List.

    ERIC Educational Resources Information Center

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This document contains the occupational duty/task lists for eight occupations in the auto mechanics series. Each occupation is divided into a number of duties. A separate page for each duty in the occupation lists the tasks in that duty along with its code number and columns to indicate whether that particular duty has been taught and to provide…

  8. Reliability and validity of the AutoCAD software method in lumbar lordosis measurement

    PubMed Central

    Letafatkar, Amir; Amirsasan, Ramin; Abdolvahabi, Zahra; Hadadnezhad, Malihe

    2011-01-01

    Objective The aim of this study was to determine the reliability and validity of the AutoCAD software method in lumbar lordosis measurement. Methods Fifty healthy volunteers with a mean age of 23 ± 1.80 years were enrolled. A lumbar lateral radiograph was taken on all participants, and the lordosis was measured according to the Cobb method. Afterward, the lumbar lordosis degree was measured via AutoCAD software and flexible ruler methods. The current study is accomplished in 2 parts: intratester and intertester evaluations of reliability as well as the validity of the flexible ruler and software methods. Results Based on the intraclass correlation coefficient, AutoCAD's reliability and validity in measuring lumbar lordosis were 0.984 and 0.962, respectively. Conclusions AutoCAD showed to be a reliable and valid method to measure lordosis. It is suggested that this method may replace those that are costly and involve health risks, such as radiography, in evaluating lumbar lordosis. PMID:22654681

  9. Reliability and validity of the AutoCAD software method in lumbar lordosis measurement.

    PubMed

    Letafatkar, Amir; Amirsasan, Ramin; Abdolvahabi, Zahra; Hadadnezhad, Malihe

    2011-12-01

    The aim of this study was to determine the reliability and validity of the AutoCAD software method in lumbar lordosis measurement. Fifty healthy volunteers with a mean age of 23 ± 1.80 years were enrolled. A lumbar lateral radiograph was taken on all participants, and the lordosis was measured according to the Cobb method. Afterward, the lumbar lordosis degree was measured via AutoCAD software and flexible ruler methods. The current study is accomplished in 2 parts: intratester and intertester evaluations of reliability as well as the validity of the flexible ruler and software methods. Based on the intraclass correlation coefficient, AutoCAD's reliability and validity in measuring lumbar lordosis were 0.984 and 0.962, respectively. AutoCAD showed to be a reliable and valid method to measure lordosis. It is suggested that this method may replace those that are costly and involve health risks, such as radiography, in evaluating lumbar lordosis.

  10. Open loop, auto reversing liquid nitrogen circulation thermal system for thermo vacuum chamber

    NASA Astrophysics Data System (ADS)

    Naidu, M. C. A.; Nolakha, Dinesh; Saharkar, B. S.; Kavani, K. M.; Patel, D. R.

    2012-11-01

    In a thermo vacuum chamber, attaining and controlling low and high temperatures (-100 Deg. C to +120 Deg. C) is a very important task. This paper describes the development of "Open loop, auto reversing liquid nitrogen based thermal system". System specifications, features, open loop auto reversing system, liquid nitrogen flow paths etc. are discussed in this paper. This thermal system consists of solenoid operated cryogenic valves, double embossed thermal plate (shroud), heating elements, temperature sensors and PLC. Bulky items like blowers, heating chambers, liquid nitrogen injection chambers, huge pipe lines and valves were not used. This entire thermal system is very simple to operate and PLC based, fully auto system with auto tuned to given set temperatures. This system requires a very nominal amount of liquid nitrogen (approx. 80 liters / hour) while conducting thermo vacuum tests. This system was integrated to 1.2m dia thermo vacuum chamber, as a part of its augmentation, to conduct extreme temperature cycling tests on passive antenna reflectors of satellites.

  11. A phase II study of V-BEAM as conditioning regimen before second auto-SCT for multiple myeloma.

    PubMed

    Wang, T-F; Fiala, M A; Cashen, A F; Uy, G L; Abboud, C N; Fletcher, T; Wu, N; Westervelt, P; DiPersio, J F; Stockerl-Goldstein, K E; Vij, R

    2014-11-01

    High-dose melphalan has been the standard conditioning regimen for auto-SCT in multiple myeloma (MM) for decades. A more effective conditioning regimen may induce deeper responses and longer remission duration. It is especially needed in the setting of second auto-SCT, which rarely achieves comparable results with the first auto-SCT using the same conditioning regimen. Here we conducted a phase II study to investigate the efficacy and safety of a conditioning regimen V-BEAM (bortezomib-BEAM) before second auto-SCT for multiple myeloma. Ten patients were enrolled from September 2012 to May 2013. The CR rate at day +100 after auto-SCT was 75%; all except for one patient remained in remission after a median follow-up of 6 months. Three patients developed Clostridium difficile infection. Two patients died within the first 30 days of auto-SCT from neutropenic colitis and overwhelming sepsis, respectively. Due to the high rate of morbidity and mortality, the study was terminated after 10 patients. In summary, although the conditioning regimen V-BEAM before second auto-SCT for MM provided promising responses, it was associated with unexpected treatment-related toxicity and should not be investigated further without modifications.

  12. Contactin-1 and Neurofascin-155/-186 Are Not Targets of Auto-Antibodies in Multifocal Motor Neuropathy.

    PubMed

    Doppler, Kathrin; Appeltshauser, Luise; Krämer, Heidrun H; Ng, Judy King Man; Meinl, Edgar; Villmann, Carmen; Brophy, Peter; Dib-Hajj, Sulayman D; Waxman, Stephen G; Weishaupt, Andreas; Sommer, Claudia

    2015-01-01

    Multifocal motor neuropathy is an immune mediated disease presenting with multifocal muscle weakness and conduction block. IgM auto-antibodies against the ganglioside GM1 are detectable in about 50% of the patients. Auto-antibodies against the paranodal proteins contactin-1 and neurofascin-155 and the nodal protein neurofascin-186 have been detected in subgroups of patients with chronic inflammatory demyelinating polyneuropathy. Recently, auto-antibodies against neurofascin-186 and gliomedin were described in more than 60% of patients with multifocal motor neuropathy. In the current study, we aimed to validate this finding, using a combination of different assays for auto-antibody detection. In addition we intended to detect further auto-antibodies against paranodal proteins, specifically contactin-1 and neurofascin-155 in multifocal motor neuropathy patients' sera. We analyzed sera of 33 patients with well-characterized multifocal motor neuropathy for IgM or IgG anti-contactin-1, anti-neurofascin-155 or -186 antibodies using enzyme-linked immunosorbent assay, binding assays with transfected human embryonic kidney 293 cells and murine teased fibers. We did not detect any IgM or IgG auto-antibodies against contactin-1, neurofascin-155 or -186 in any of our multifocal motor neuropathy patients. We conclude that auto-antibodies against contactin-1, neurofascin-155 and -186 do not play a relevant role in the pathogenesis in this cohort with multifocal motor neuropathy.

  13. Relevance of Flow Cytometric Auto-Crossmatch to the Post-transplant Course of Kidney Transplant Recipients.

    PubMed

    Demir, E; Yeğit, O; Erol, A; Akgül, S U; Çalışkan, B; Bayraktar, A; Çalışkan, Y; Türkmen, A; Savran, F O; Sever, M S

    2017-04-01

    The crossmatch test is essential prior to kidney transplantation (tx) to confirm compatibility between the donor and the recipient. However, its results can be misleading due to "undetectable antibodies" in the recipient's serum. To establish if undetectable autoantibodies are responsible for a positive result, an auto-crossmatch test can be performed. In this study, we aim to determine the long-term prognostic value of auto-flow cytometric auto-crossmatch (FCXM) test on kidney survival in kidney tx recipients. The primary outcome variable was reduced renal function. Secondary endpoints were incidence of biopsy-confirmed chronic antibody-mediated rejection (CAMR) and recurrent glomerulonephritis (GN). There were no differences regarding initial serum creatinine levels between the study and control groups (P = .441). Patients who had positive auto-B FCXM had a significantly reduced renal function compared with the control group (P = .016). Four patients developed biopsy-confirmed CAMR in the study group and 1 patient in the control group (P = .047). Five patients had biopsy-confirmed recurrent GN in the GN study group, and only 1 patient had recurrent GN in the GN control group (P = .026). Kidney transplant recipients with positive auto-FCXM test had significantly reduced renal function and a higher incidence of recurrent GN and CAMR compared with the control group. The findings of this study suggest a potential role of auto-antibody causing positive auto-FCXM test result, meanwhile increasing the risk of CAMR, recurrent GN, and new-onset diabetes after tx. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Empiric Auto-Titrating CPAP in People with Suspected Obstructive Sleep Apnea

    PubMed Central

    Drummond, Fitzgerald; Doelken, Peter; Ahmed, Qanta A.; Gilbert, Gregory E.; Strange, Charlie; Herpel, Laura; Frye, Michael D.

    2010-01-01

    Objective: Efficient diagnosis and treatment of obstructive sleep apnea (OSA) can be difficult because of time delays imposed by clinic visits and serial overnight polysomnography. In some cases, it may be desirable to initiate treatment for suspected OSA prior to polysomnography. Our objective was to compare the improvement of daytime sleepiness and sleep-related quality of life of patients with high clinical likelihood of having OSA who were randomly assigned to receive empiric auto-titrating continuous positive airway pressure (CPAP) while awaiting polysomnogram versus current usual care. Methods: Serial patients referred for overnight polysomnography who had high clinical likelihood of having OSA were randomly assigned to usual care or immediate initiation of auto-titrating CPAP. Epworth Sleepiness Scale (ESS) scores and the Functional Outcomes of Sleep Questionnaire (FOSQ) scores were obtained at baseline, 1 month after randomization, and again after initiation of fixed CPAP in control subjects and after the sleep study in auto-CPAP patients. Results: One hundred nine patients were randomized. Baseline demographics, daytime sleepiness, and sleep-related quality of life scores were similar between groups. One-month ESS and FOSQ scores were improved in the group empirically treated with auto-titrating CPAP. ESS scores improved in the first month by a mean of −3.2 (confidence interval −1.6 to −4.8, p < 0.001) and FOSQ scores improved by a mean of 1.5, (confidence interval 0.5 to 2.7, p = 0.02), whereas scores in the usual-care group did not change (p = NS). Following therapy directed by overnight polysomnography in the control group, there were no differences in ESS or FOSQ between the groups. No adverse events were observed. Conclusion: Empiric auto-CPAP resulted in symptomatic improvement of daytime sleepiness and sleep-related quality of life in a cohort of patients awaiting polysomnography who had a high pretest probability of having OSA. Additional

  15. Micromagnetic study of auto-oscillation modes in spin-Hall nano-oscillators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ulrichs, H., E-mail: henning.ulrichs@uni-muenster.de; Demidov, V. E.; Demokritov, S. O.

    2014-01-27

    We present a numerical study of magnetization dynamics in a recently introduced spin torque nano-oscillator, whose operational principle relies on the spin-Hall effect—spin-Hall nano-oscillators. Our numerical results show good agreement with the experimentally observed behaviors and provide detailed information about the features of the primary auto-oscillation mode observed in the experiments. They also clarify the physical nature of the secondary auto-oscillation mode, which was experimentally observed under certain conditions only.

  16. Magnonic Crystal as a Delay Line for Low-Noise Auto-Oscillator

    DTIC Science & Technology

    2015-05-12

    Magnonic crystal as a delay line for low-noise auto-oscillator Elena Bankowski and Thomas Meitzler U.S. Army TARDEC, Warren, Michigan 48397, USA...authors propose to use the magnonic crystal patterned on the YIG magnetic film as an efficient delay line in the feedback loop of tunable auto-oscillator...increasing the thickness of such delay line as compare to the YIG film with no pattern. In turn, use of this magnonic crystal opens a way to improve

  17. [Psychosocial vulnerability and substance use screening during pregnancy: Evaluation of a composite auto-questionnaire versus usual medical questioning].

    PubMed

    Fline-Barthes, M-H; Vandendriessche, D; Gaugue, J; Urso, L; Therby, D; Subtil, D

    2015-05-01

    To evaluate auto-questionnaire use for psychosocial vulnerability and substance use (smoking, alcohol consumption, depression, intimate violence) screening during pregnancy versus usual medical report. An auto-questionnaire based on validated tests (Fagerström/HSI, T-ACE, EPDS, SSQ6) was proposed to 1977 pregnant patients at their first obstetrical consultation. We compared results of auto-questionnaire and usual medical questioning. The auto-questionnaire was filled by 1676 pregnant patients (89.4 %). The two Fagerström/HIS questions showed that 20.7 % smoked during pregnancy. T-ACE score was better than usual medical questioning to detect excessive alcohol consumption (4.0 % vs 0.1 %, P<0.05). Drug use before pregnancy was reported by 9.8 % patients in auto-questionnaire, but was only found in 4.9 % of medical files (P<0.001). Seven percent patients reported at least 3 depressive symptoms on 4 purposed in auto-questionnaire. Intimate violence, physical or psychological, was reported in 9.4 %. All of these vulnerability factors were linked together, in auto-questionnaire or in usual medical reports. Using auto-questionnaire based on standardized screening tests could help medical practioneers to detect psychosocial vulnerability and/or substance use during pregnancy. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  18. 76 FR 1065 - Security Zone; 23rd Annual North American International Auto Show, Detroit River, Detroit, MI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-07

    ...-AA87 Security Zone; 23rd Annual North American International Auto Show, Detroit River, Detroit, MI... officials at the 23rd Annual North American International Auto Show (NAIAS) being held at Cobo Hall in... 23rd Annual North American International Auto Show (NAIAS) being held at Cobo Hall in downtown Detroit...

  19. 77 FR 16227 - Frank Myers AutoMaxx, LLC; Analysis of Proposed Consent Order To Aid Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-20

    ... FEDERAL TRADE COMMISSION [File No. 112 3206] Frank Myers AutoMaxx, LLC; Analysis of Proposed... ``Frank Myers AutoMaxx, File No. 112 3206'' on your comment, and file your comment online at https... April 16, 2012. Write ``Frank Myers AutoMaxx, File No. 112 3206'' on your comment. Your comment...

  20. Sensitivity to external signals and synchronization properties of a non-isochronous auto-oscillator with delayed feedback

    PubMed Central

    Tiberkevich, Vasil S.; Khymyn, Roman S.; Tang, Hong X.; Slavin, Andrei N.

    2014-01-01

    For auto-oscillators of different nature (e.g. active cells in a human heart under the action of a pacemaker, neurons in brain, spin-torque nano-oscillators, micro and nano-mechanical oscillators, or generating Josephson junctions) a critically important property is their ability to synchronize with each other. The synchronization properties of an auto oscillator are directly related to its sensitivity to external signals. Here we demonstrate that a non-isochronous (having generation frequency dependent on the amplitude) auto-oscillator with delayed feedback can have an extremely high sensitivity to external signals and unusually large width of the phase-locking band near the boundary of the stable auto-oscillation regime. This property could be used for the development of synchronized arrays of non-isochronous auto-oscillators in physics and engineering, and, for instance, might bring a better fundamental understanding of ways to control a heart arrythmia in medicine. PMID:24464086

  1. Incidence of auto-immune pemphigus in the Midi-Pyrénées region in 2002-2006.

    PubMed

    Thomas, M; Paul, C; Berard, E; Fortenfant, F; Mazereeuw-Hautier, J; Livideanu, C; Viraben, R; Meyer, N

    2010-01-01

    Auto-immune pemphigus is an organ-specific immune disorder due to pathogenic auto-antibodies. Both genetic and environmental factors have been associated with the occurrence of auto-immune pemphigus. Little is known about the epidemiology of auto-immune pemphigus in western Europe. To evaluate the incidence of auto-immune pemphigus in south-western France (namely the Midi-Pyrénées region) in a 5-year period between 2002 and 2006. We performed a retrospective study of the annual incidence of auto-immune pemphigus diagnosed in the Midi-Pyrénées region, between January 1, 2002, and December 31, 2006. Possible cases of pemphigus were initially selected using skin direct immunofluorescence (DIF) databases from all laboratories in the Midi-Pyrénées region. Systematic validation of all cases was performed by two of the authors (N.M., M.T.). To qualify as a case of auto-immune pemphigus, patients had to fulfil the following criteria: history of clinical signs of pemphigus as assessed by a dermatologist and a positive DIF. To be included in the study, validated cases of auto-immune pemphigus had to fulfil the following criteria: the date of first positive skin DIF between January 1, 2002, and December 31, 2006, and patient living in the Midi-Pyrénées region at the time of the first positive skin DIF. Between 2002 and 2006, 91 patients with positive DIF were identified. Fifty-four patients with positive DIF did not meet the validation criteria for the study. Thirty-seven cases were included in the analysis. The crude annual mean incidence of auto-immune pemphigus between 2002 and 2006 was 2.7 cases/10(6) inhabitants/year (95% CI: 1.87-3.69). The world-population-standardized annual mean incidence of auto-immune pemphigus was 1.55 (95% CI: 0.99-2.11). We report a 1.55/10(6) inhabitants/year world-population-standardized incidence of auto-immune pemphigus in the south-west of France. A nationwide epidemiological study of pemphigus should be performed in France.

  2. Auto-Gopher-II: an autonomous wireline rotary-hammer ultrasonic drill

    NASA Astrophysics Data System (ADS)

    Badescu, Mircea; Lee, Hyeong Jae; Sherrit, Stewart; Bao, Xiaoqi; Bar-Cohen, Yoseph; Jackson, Shannon; Chesin, Jacob; Zacny, Kris; Paulsen, Gale L.; Mellerowicz, Bolek; Kim, Daniel

    2017-04-01

    Developing technologies that would enable future NASA exploration missions to penetrate deeper into the subsurface of planetary bodies for sample collection is of great importance. Performing these tasks while using minimal mass/volume systems and with low energy consumption is another set of requirements imposed on such technologies. A deep drill, called Auto-Gopher II, is currently being developed as a joint effort between JPL's NDEAA laboratory and Honeybee Robotics Corp. The Auto-Gopher II is a wireline rotary-hammer drill that combines formation breaking by hammering using an ultrasonic actuator and cuttings removal by rotating a fluted auger bit. The hammering mechanism is based on the Ultrasonic/Sonic Drill/Corer (USDC) mechanism that has been developed as an adaptable tool for many drilling and coring applications. The USDC uses an intermediate free-flying mass to transform high frequency vibrations of a piezoelectric transducer horn tip into sonic hammering of the drill bit. The USDC concept was used in a previous task to develop an Ultrasonic/Sonic Ice Gopher and then integrated into a rotary hammer device to develop the Auto-Gopher-I. The lessons learned from these developments are being integrated into the development of the Auto- Gopher-II, an autonomous deep wireline drill with integrated cuttings and sample management and drive electronics. Subsystems of the wireline drill are being developed in parallel at JPL and Honeybee Robotics Ltd. This paper presents the development efforts of the piezoelectric actuator, cuttings removal and retention flutes and drive electronics.

  3. Auto covariance computer

    NASA Technical Reports Server (NTRS)

    Hepner, T. E.; Meyers, J. F. (Inventor)

    1985-01-01

    A laser velocimeter covariance processor which calculates the auto covariance and cross covariance functions for a turbulent flow field based on Poisson sampled measurements in time from a laser velocimeter is described. The device will process a block of data that is up to 4096 data points in length and return a 512 point covariance function with 48-bit resolution along with a 512 point histogram of the interarrival times which is used to normalize the covariance function. The device is designed to interface and be controlled by a minicomputer from which the data is received and the results returned. A typical 4096 point computation takes approximately 1.5 seconds to receive the data, compute the covariance function, and return the results to the computer.

  4. Research on AutoCAD secondary development and function expansion based on VBA technology

    NASA Astrophysics Data System (ADS)

    Zhang, Runmei; Gu, Yehuan

    2017-06-01

    AutoCAD is the most widely used drawing tool among the similar design drawing products. In the process of drawing different types of design drawings of the same product, there are a lot of repetitive and single work contents. The traditional manual method uses a drawing software AutoCAD drawing graphics with low efficiency, high error rate and high input cost shortcomings and many more. In order to solve these problems, the design of the parametric drawing system of the hot-rolled I-beam (steel beam) cross-section is completed by using the VBA secondary development tool and the Access database software with large-capacity storage data, and the analysis of the functional extension of the plane drawing and the parametric drawing design in this paper. For the secondary development of AutoCAD functions, the system drawing work will be simplified and work efficiency also has been greatly improved. This introduction of parametric design of AutoCAD drawing system to promote the industrial mass production and related industries economic growth rate similar to the standard I-beam hot-rolled products.

  5. Estimation of the auto frequency response function at unexcited points using dummy masses

    NASA Astrophysics Data System (ADS)

    Hosoya, Naoki; Yaginuma, Shinji; Onodera, Hiroshi; Yoshimura, Takuya

    2015-02-01

    If structures with complex shapes have space limitations, vibration tests using an exciter or impact hammer for the excitation are difficult. Although measuring the auto frequency response function at an unexcited point may not be practical via a vibration test, it can be obtained by assuming that the inertia acting on a dummy mass is an external force on the target structure upon exciting a different excitation point. We propose a method to estimate the auto frequency response functions at unexcited points by attaching a small mass (dummy mass), which is comparable to the accelerometer mass. The validity of the proposed method is demonstrated by comparing the auto frequency response functions estimated at unexcited points in a beam structure to those obtained from numerical simulations. We also consider random measurement errors by finite element analysis and vibration tests, but not bias errors. Additionally, the applicability of the proposed method is demonstrated by applying it to estimate the auto frequency response function of the lower arm in a car suspension.

  6. Metabolic syndrome and occupation: Any association? Prevalence among auto technicians and school teachers in South West Nigeria.

    PubMed

    Akintunde, Adeseye A; Oloyede, Taiwo W

    2017-11-01

    To determine occupational association with metabolic syndrome among auto technicians and school teachers. One hundred and sixty six subjects were selected for this study. Clinical data was obtained while laboratory investigations including plasma glucose and lipid profile were performed. Statistical analysis was done with SPSS 20.0. P<0.05 was taken as statistically significant. School teachers had significantly higher mean total cholesterol and LDL-cholesterol compared to auto technicians. Mean serum triglycerides was significantly higher among auto-technicians compared to school teachers in this study. The prevalence of some conventional cardiovascular risk factors was significantly higher among auto-technicians compared to school teachers: Impaired blood glucose (9.6% vs. 1.2%, p<0.05), hypertriglyceridaemia (18.1% vs. 7.2%, p<0.05) and low HDL-Cholesterol (47.0% vs. 37.3%, p<0.05) respectively. However elevated LDL-cholesterol (56.6% vs. 32.5%, p<0.05) was significantly more common among school teachers compared to auto-technicians. Based on the WHO and the Harmonized criteria, metabolic syndrome was more frequent among auto-technicians compared to school teachers. (8.4% vs. 1.2% and 19.3% vs. 7.2% respectively, p<0.05) CONCLUSION: The prevalence of metabolic syndrome appears to be significantly higher among auto technicians despite their high level of physical activity, exertion and education compared to teachers. This may be related to the increased occupational exposure to organic and inorganic materials from dust particles, oil and oil related matter and particulate matter among auto technicians. Prompt definitive evaluation of this concept and appropriate health education to encourage safety mechanism can reduce this burden of metabolic syndrome among auto technicians in Nigeria. Copyright © 2016 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  7. Measurements of auto-antibodies to α-synuclein in the serum and cerebral spinal fluids of patients with Parkinson's disease.

    PubMed

    Akhtar, Rizwan S; Licata, Joseph P; Luk, Kelvin C; Shaw, Leslie M; Trojanowski, John Q; Lee, Virginia M-Y

    2018-03-03

    Biomarkers for α-synuclein are needed for diagnosis and prognosis in Parkinson's disease (PD). Endogenous auto-antibodies to α-synuclein could serve as biomarkers for underlying synucleinopathy, but previous assessments of auto-antibodies have shown variability and inconsistent clinical correlations. We hypothesized that auto-antibodies to α-synuclein could be diagnostic for PD and explain its clinical heterogeneity. To test this hypothesis, we developed an enzyme-linked immunosorbent assay for measuring α-synuclein auto-antibodies in human samples. We evaluated 69 serum samples (16 healthy controls (HC) and 53 PD patients) and 145 CSF samples (52 HC and 93 PD patients) from our Institution. Both serum and CSF were available for 24 participants. Males had higher auto-antibody levels than females in both fluids. CSF auto-antibody levels were significantly higher in PD patients as compared to HC, whereas serum levels were not significantly different. CSF auto-antibody levels did not associate with amyloid-β 1-42 , total tau, or phosphorylated tau. CSF auto-antibody levels correlated with performance on the Montreal Cognitive Assessment, even when controlled for CSF amyloidβ 1-42 . CSF hemoglobin levels, as a proxy for contamination of CSF by blood during lumbar puncture, did not influence these observations. Using recombinant α-synuclein with N- and C-terminal truncations, we found that CSF auto-antibodies target amino acids 100 through 120 of α-synuclein. We conclude that endogenous CSF auto-antibodies are significantly higher in PD patients as compared to HC, suggesting that they could indicate the presence of underlying synucleinopathy. These auto-antibodies associate with poor cognition, independently of CSF amyloidβ 1-42 ., and target a select C-terminal region of α-synuclein. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  8. Research with Rawness: The Remembering and Repeating of Auto/Biographical Ethnographic Research Processes

    ERIC Educational Resources Information Center

    Sagan, Olivia

    2007-01-01

    This paper explores the auto/biographicity of ethnographic research, describing the way in which our research pursuits can be seen as the replaying of past agendas. It looks specifically at the auto/biographic interview as part of the ethnographic data collected, positing it as the site of co-construction of new memory, and the re-enactment of…

  9. Auto-Mechanics Course. Bilingual Vocational Instructional Materials.

    ERIC Educational Resources Information Center

    Lopez-Cox, Guadalupe

    This auto-mechanics course, one of a series of bilingual English-Spanish vocational education courses, is designed to introduce the basic skills that an automotive mechanics student should know. It is geared to teach the student basic manipulative skills, safety judgments, proper work habits, desirable attitudes, and proper behavior for initial…

  10. An Analysis of the Auto Mechanic Occupation.

    ERIC Educational Resources Information Center

    Conner, Michael; Thoman, LeRoy

    The general purpose of the occupational analysis is to provide workable, basic information dealing with the many and varied duties performed in the auto mechanic occupation. It identifies the broad area of skills and knowledge necessary to perform various tasks involved in diagnosis, maintenance, and repair of automotive systems. Selected…

  11. Adrenaline auto-injectors for the treatment of anaphylaxis with and without cardiovascular collapse in the community.

    PubMed

    Sheikh, Aziz; Simons, F Estelle R; Barbour, Victoria; Worth, Allison

    2012-08-15

    Anaphylaxis is a serious hypersensitivity reaction that is rapid in onset and may cause death. Adrenaline (epinephrine) auto-injectors are recommended as the initial, potentially life-saving treatment of choice for anaphylaxis in the community, but they are not universally available and have limitations in their use. To assess the effectiveness of adrenaline (epinephrine) auto-injectors in relieving respiratory, cardiovascular, and other symptoms during episodes of anaphylaxis that occur in the community. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2012, Issue 1), MEDLINE (Ovid SP) (1950 to January 2012), EMBASE (Ovid SP) (1980 to January 2012 ), CINAHL (EBSCO host) (1982 to January 2012 ), AMED (EBSCO host) (1985 to January 2012 ), LILACS, (BIREME) (1980 to January 2012 ), ISI Web of Science (1950 to January 2012 ). We adapted our search terms for other databases. We also searched websites listing on-going trials: the World Health Organization International Clinical Trials Registry Platform, the UK Clinical Research Network Study Portfolio, and the meta Register of Controlled Trials; and contacted pharmaceutical companies who manufacture adrenaline auto-injectors in an attempt to locate unpublished material. Randomized and quasi-randomized controlled trials comparing auto-injector administration of adrenaline with any control including no intervention, placebo, or other adrenergic agonists were eligible for inclusion. Two authors independently assessed articles for inclusion. None of the 1328 studies that were identified satisfied the inclusion criteria. Based on this review, we cannot make any new recommendations on the effectiveness of adrenaline auto-injectors for the treatment of anaphylaxis. Although randomized, double-blind, placebo-controlled clinical trials of high methodological quality are necessary to define the true extent of benefits from the administration of adrenaline in anaphylaxis via an auto

  12. Increased glycosylation efficiency of recombinant proteins in Escherichia coli by auto-induction.

    PubMed

    Ding, Ning; Yang, Chunguang; Sun, Shenxia; Han, Lichi; Ruan, Yao; Guo, Longhua; Hu, Xuejun; Zhang, Jianing

    2017-03-25

    Escherichia coli cells have been considered as promising hosts for producing N-glycosylated proteins since the successful production of N-glycosylated protein in E. coli with the pgl (N-linked protein glycosylation) locus from Campylobacter jejuni. However, one hurdle in producing N-glycosylated proteins in large scale using E. coli is inefficient glycan glycosylation. In this study, we developed a strategy for the production of N-glycosylated proteins with high efficiency via an optimized auto-induction method. The 10th human fibronectin type III domain (FN3) was engineered with native glycosylation sequon DFNRSK and optimized DQNAT sequon in C-terminus with flexible linker as acceptor protein models. The resulting glycosylation efficiencies were confirmed by Western blots with anti-FLAG M1 antibody. Increased efficiency of glycosylation was obtained by changing the conventional IPTG induction to auto-induction method, which increased the glycosylation efficiencies from 60% and 75% up to 90% and 100% respectively. Moreover, in the condition of inserting the glycosylation sequon in the loop of FN3 (the acceptor sequon with local structural conformation), the glycosylation efficiency was increased from 35% to 80% by our optimized auto-induction procedures. To justify the potential for general application of the optimized auto-induction method, the reconstituted lsg locus from Haemophilus influenzae and PglB from C. jejuni were utilized, and this led to 100% glycosylation efficiency. Our studies provided quantitative evidence that the optimized auto-induction method will facilitate the large-scale production of pure exogenous N-glycosylation proteins in E. coli cells. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Pareto-optimal multi-objective dimensionality reduction deep auto-encoder for mammography classification.

    PubMed

    Taghanaki, Saeid Asgari; Kawahara, Jeremy; Miles, Brandon; Hamarneh, Ghassan

    2017-07-01

    Feature reduction is an essential stage in computer aided breast cancer diagnosis systems. Multilayer neural networks can be trained to extract relevant features by encoding high-dimensional data into low-dimensional codes. Optimizing traditional auto-encoders works well only if the initial weights are close to a proper solution. They are also trained to only reduce the mean squared reconstruction error (MRE) between the encoder inputs and the decoder outputs, but do not address the classification error. The goal of the current work is to test the hypothesis that extending traditional auto-encoders (which only minimize reconstruction error) to multi-objective optimization for finding Pareto-optimal solutions provides more discriminative features that will improve classification performance when compared to single-objective and other multi-objective approaches (i.e. scalarized and sequential). In this paper, we introduce a novel multi-objective optimization of deep auto-encoder networks, in which the auto-encoder optimizes two objectives: MRE and mean classification error (MCE) for Pareto-optimal solutions, rather than just MRE. These two objectives are optimized simultaneously by a non-dominated sorting genetic algorithm. We tested our method on 949 X-ray mammograms categorized into 12 classes. The results show that the features identified by the proposed algorithm allow a classification accuracy of up to 98.45%, demonstrating favourable accuracy over the results of state-of-the-art methods reported in the literature. We conclude that adding the classification objective to the traditional auto-encoder objective and optimizing for finding Pareto-optimal solutions, using evolutionary multi-objective optimization, results in producing more discriminative features. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Iterative model building, structure refinement and density modification with the PHENIX AutoBuild wizard.

    PubMed

    Terwilliger, Thomas C; Grosse-Kunstleve, Ralf W; Afonine, Pavel V; Moriarty, Nigel W; Zwart, Peter H; Hung, Li Wei; Read, Randy J; Adams, Paul D

    2008-01-01

    The PHENIX AutoBuild wizard is a highly automated tool for iterative model building, structure refinement and density modification using RESOLVE model building, RESOLVE statistical density modification and phenix.refine structure refinement. Recent advances in the AutoBuild wizard and phenix.refine include automated detection and application of NCS from models as they are built, extensive model-completion algorithms and automated solvent-molecule picking. Model-completion algorithms in the AutoBuild wizard include loop building, crossovers between chains in different models of a structure and side-chain optimization. The AutoBuild wizard has been applied to a set of 48 structures at resolutions ranging from 1.1 to 3.2 A, resulting in a mean R factor of 0.24 and a mean free R factor of 0.29. The R factor of the final model is dependent on the quality of the starting electron density and is relatively independent of resolution.

  15. Iterative model building, structure refinement and density modification with the PHENIX AutoBuild wizard

    PubMed Central

    Terwilliger, Thomas C.; Grosse-Kunstleve, Ralf W.; Afonine, Pavel V.; Moriarty, Nigel W.; Zwart, Peter H.; Hung, Li-Wei; Read, Randy J.; Adams, Paul D.

    2008-01-01

    The PHENIX AutoBuild wizard is a highly automated tool for iterative model building, structure refinement and density modification using RESOLVE model building, RESOLVE statistical density modification and phenix.refine structure refinement. Recent advances in the AutoBuild wizard and phenix.refine include automated detection and application of NCS from models as they are built, extensive model-completion algorithms and automated solvent-molecule picking. Model-completion algorithms in the AutoBuild wizard include loop building, crossovers between chains in different models of a structure and side-chain optimization. The AutoBuild wizard has been applied to a set of 48 structures at resolutions ranging from 1.1 to 3.2 Å, resulting in a mean R factor of 0.24 and a mean free R factor of 0.29. The R factor of the final model is dependent on the quality of the starting electron density and is relatively independent of resolution. PMID:18094468

  16. Numerical Analysis of the Interaction between Thermo-Fluid Dynamics and Auto-Ignition Reaction in Spark Ignition Engines

    NASA Astrophysics Data System (ADS)

    Saijyo, Katsuya; Nishiwaki, Kazuie; Yoshihara, Yoshinobu

    The CFD simulations were performed integrating the low-temperature oxidation reaction. Analyses were made with respect to the first auto-ignition location in the case of a premixed-charge compression auto-ignition in a laminar flow field and in the case of the auto-ignition in an end gas during an S. I. Engine combustion process. In the latter simulation, the spatially-filtered transport equations were solved to express fluctuating temperatures in a turbulent flow in consideration of strong non-linearity to temperature in the reaction equations. It is suggested that the first auto-ignition location does not always occur at higher-temperature locations and that the difference in the locations of the first auto-ignition depends on the time period during which the local end gas temperature passes through the region of shorter ignition delay, including the NTC region.

  17. Criteria for Operational Approval of Auto Guidance Systems

    DOT National Transportation Integrated Search

    1997-03-18

    This advisory circular (AC) states an acceptable means, but not the only means, : for obtaining operational approval of the initial engagement or use of an Auto : Flight Guidance System (AFGS) under Title 14 of the Code of Federal Regulations : (14 C...

  18. Face detection assisted auto exposure: supporting evidence from a psychophysical study

    NASA Astrophysics Data System (ADS)

    Jin, Elaine W.; Lin, Sheng; Dharumalingam, Dhandapani

    2010-01-01

    Face detection has been implemented in many digital still cameras and camera phones with the promise of enhancing existing camera functions (e.g. auto exposure) and adding new features to cameras (e.g. blink detection). In this study we examined the use of face detection algorithms in assisting auto exposure (AE). The set of 706 images, used in this study, was captured using Canon Digital Single Lens Reflex cameras and subsequently processed with an image processing pipeline. A psychophysical study was performed to obtain optimal exposure along with the upper and lower bounds of exposure for all 706 images. Three methods of marking faces were utilized: manual marking, face detection algorithm A (FD-A), and face detection algorithm B (FD-B). The manual marking method found 751 faces in 426 images, which served as the ground-truth for face regions of interest. The remaining images do not have any faces or the faces are too small to be considered detectable. The two face detection algorithms are different in resource requirements and in performance. FD-A uses less memory and gate counts compared to FD-B, but FD-B detects more faces and has less false positives. A face detection assisted auto exposure algorithm was developed and tested against the evaluation results from the psychophysical study. The AE test results showed noticeable improvement when faces were detected and used in auto exposure. However, the presence of false positives would negatively impact the added benefit.

  19. Thermodynamic analysis of tar reforming through auto-thermal reforming process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nurhadi, N., E-mail: nurhadi@tekmira.esdm.go.id; Diniyati, Dahlia; Efendi, M. Ade Andriansyah

    2015-12-29

    Fixed bed gasification is a simple and suitable technology for small scale power generation. One of the disadvantages of this technology is producing tar. So far, tar is not utilized yet and being waste that should be treated into a more useful product. This paper presents a thermodynamic analysis of tar conversion into gas producer through non-catalytic auto-thermal reforming technology. Tar was converted into components, C, H, O, N and S, and then reacted with oxidant such as mixture of air or pure oxygen. Thus, this reaction occurred auto-thermally and reached chemical equilibrium. The sensitivity analysis resulted that the mostmore » promising process performance occurred at flow rate of air was reached 43% of stoichiometry while temperature of process is 1100°C, the addition of pure oxygen is 40% and preheating of oxidant flow is 250°C. The yield of the most promising process performance between 11.15-11.17 kmol/h and cold gas efficiency was between 73.8-73.9%.The results of this study indicated that thermodynamically the conversion of tar into producer gas through non-catalytic auto-thermal reformingis more promising.« less

  20. Auto industry : a framework for considering federal financial assistance.

    DOT National Transportation Integrated Search

    2008-12-05

    The current economic downturn has brought significant financial stress to the auto manufacturing industry. Recent deteriorating financial, real estate, and labor markets have reduced consumer confidence and available credit, and automobile purchases ...

  1. Error Estimation for the Linearized Auto-Localization Algorithm

    PubMed Central

    Guevara, Jorge; Jiménez, Antonio R.; Prieto, Jose Carlos; Seco, Fernando

    2012-01-01

    The Linearized Auto-Localization (LAL) algorithm estimates the position of beacon nodes in Local Positioning Systems (LPSs), using only the distance measurements to a mobile node whose position is also unknown. The LAL algorithm calculates the inter-beacon distances, used for the estimation of the beacons’ positions, from the linearized trilateration equations. In this paper we propose a method to estimate the propagation of the errors of the inter-beacon distances obtained with the LAL algorithm, based on a first order Taylor approximation of the equations. Since the method depends on such approximation, a confidence parameter τ is defined to measure the reliability of the estimated error. Field evaluations showed that by applying this information to an improved weighted-based auto-localization algorithm (WLAL), the standard deviation of the inter-beacon distances can be improved by more than 30% on average with respect to the original LAL method. PMID:22736965

  2. Empiric auto-titrating CPAP in people with suspected obstructive sleep apnea.

    PubMed

    Drummond, Fitzgerald; Doelken, Peter; Ahmed, Qanta A; Gilbert, Gregory E; Strange, Charlie; Herpel, Laura; Frye, Michael D

    2010-04-15

    Efficient diagnosis and treatment of obstructive sleep apnea (OSA) can be difficult because of time delays imposed by clinic visits and serial overnight polysomnography. In some cases, it may be desirable to initiate treatment for suspected OSA prior to polysomnography. Our objective was to compare the improvement of daytime sleepiness and sleep-related quality of life of patients with high clinical likelihood of having OSA who were randomly assigned to receive empiric auto-titrating continuous positive airway pressure (CPAP) while awaiting polysomnogram versus current usual care. Serial patients referred for overnight polysomnography who had high clinical likelihood of having OSA were randomly assigned to usual care or immediate initiation of auto-titrating CPAP. Epworth Sleepiness Scale (ESS) scores and the Functional Outcomes of Sleep Questionnaire (FOSQ) scores were obtained at baseline, 1 month after randomization, and again after initiation of fixed CPAP in control subjects and after the sleep study in auto-CPAP patients. One hundred nine patients were randomized. Baseline demographics, daytime sleepiness, and sleep-related quality of life scores were similar between groups. One-month ESS and FOSQ scores were improved in the group empirically treated with auto-titrating CPAP. ESS scores improved in the first month by a mean of -3.2 (confidence interval -1.6 to -4.8, p < 0.001) and FOSQ scores improved by a mean of 1.5, (confidence interval 0.5 to 2.7, p = 0.02), whereas scores in the usual-care group did not change (p = NS). Following therapy directed by overnight polysomnography in the control group, there were no differences in ESS or FOSQ between the groups. No adverse events were observed. Empiric auto-CPAP resulted in symptomatic improvement of daytime sleepiness and sleep-related quality of life in a cohort of patients awaiting polysomnography who had a high pretest probability of having OSA. Additional studies are needed to evaluate the applicability

  3. Experimental Study of Magnetic Field Production and Dielectric Breakdown of Auto-Magnetizing Liners

    NASA Astrophysics Data System (ADS)

    Shipley, Gabriel; Awe, Thomas; Hutchinson, Trevor; Hutsel, Brian; Slutz, Stephen; Lamppa, Derek

    2017-10-01

    AutoMag liners premagnetize the fuel in MagLIF targets and provide enhanced x-ray diagnostic access and increased current delivery without requiring external field coils. AutoMag liners are composite liners made with discrete metallic helical conduction paths separated by insulating material. First, a low dI/dt ``foot'' current pulse (1 MA in 100 ns) premagnetizes the fuel. Next, a higher dI/dt pulse with larger induced electric field initiates breakdown on the composite liner's; surface, switching the current from helical to axial to implode the liner. Experiments on MYKONOS have tested the premagnetization and breakdown phases of AutoMag and demonstrate axial magnetic fields above 90 Tesla for a 550 kA peak current pulse. Electric fields of 17 MV/m have been generated before breakdown. AutoMag may enhance MagLIF performance by increasing the premagnetization strength significantly above 30 T, thus reducing thermal-conduction losses and mitigating anomalous diffusion of magnetic field out of hotter fuel regions, by, for example, the Nernst thermoelectric effect. This project was funded in part by Sandia's Laboratory Directed Research and Development Program (Projects No. 200169 and 195306).

  4. AutoDrug: fully automated macromolecular crystallography workflows for fragment-based drug discovery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, Yingssu; Stanford University, 333 Campus Drive, Mudd Building, Stanford, CA 94305-5080; McPhillips, Scott E.

    New software has been developed for automating the experimental and data-processing stages of fragment-based drug discovery at a macromolecular crystallography beamline. A new workflow-automation framework orchestrates beamline-control and data-analysis software while organizing results from multiple samples. AutoDrug is software based upon the scientific workflow paradigm that integrates the Stanford Synchrotron Radiation Lightsource macromolecular crystallography beamlines and third-party processing software to automate the crystallography steps of the fragment-based drug-discovery process. AutoDrug screens a cassette of fragment-soaked crystals, selects crystals for data collection based on screening results and user-specified criteria and determines optimal data-collection strategies. It then collects and processes diffraction data,more » performs molecular replacement using provided models and detects electron density that is likely to arise from bound fragments. All processes are fully automated, i.e. are performed without user interaction or supervision. Samples can be screened in groups corresponding to particular proteins, crystal forms and/or soaking conditions. A single AutoDrug run is only limited by the capacity of the sample-storage dewar at the beamline: currently 288 samples. AutoDrug was developed in conjunction with RestFlow, a new scientific workflow-automation framework. RestFlow simplifies the design of AutoDrug by managing the flow of data and the organization of results and by orchestrating the execution of computational pipeline steps. It also simplifies the execution and interaction of third-party programs and the beamline-control system. Modeling AutoDrug as a scientific workflow enables multiple variants that meet the requirements of different user groups to be developed and supported. A workflow tailored to mimic the crystallography stages comprising the drug-discovery pipeline of CoCrystal Discovery Inc. has been deployed and

  5. My Story in a Profession of Stories: Auto Ethnography-- An Empowering Methodology for Educators

    ERIC Educational Resources Information Center

    Dyson, Michael

    2007-01-01

    This paper highlights a distinctive way to research and present issues within education using metaphor and the qualitative narrative methodology known as auto ethnography. Auto ethnographic writing links the personal to the cultural and is recognised as a methodology that combines the method with the writing of the text, which in turn explicates…

  6. [PSYCHOTHERAPEUTIC INTERVENTIONS IN PATIENTS WITH AUTO-AGGRESSIVE BEHAVIOR DURING THE FIRST PSYCHOTIC EPISODE].

    PubMed

    Mudrenko, I; Potapov, A; Sotnikov, D; Kolenko, O; Kmyta, A

    2017-09-01

    In this article the formation of psychopathological predictors auto-aggressive behavior in patients with a first psychotic episode were identified, which became "targets" in the framework of a comprehensive emergency suicide assistance to conduct the crisis psychotherapy. The work was done on the basis of the Sumy regional psychoneurologic dispensary, where 100 patients with a first psychotic episode were examined: 52 of them (core group) had suicidal symptoms and 48 (control group) had not. According to the test results of severity of auto-aggressive predictors (pre-suicidal syndrome) to clinicopsychopathological predictors of auto-aggressive behavior include: the narrowing of the cognitive function (p≤0,001), the avoidance of interpersonal contact (r≤0,001), the presence of affective (p≤0,001) and vegetative (p≤0,01) violations, the autoaggression of moderate severity (p≤0,001) and impulsivity (p≤0,001). Patients of the core group with the auto-aggressive behavior (n=58) completed a course of a crisis psychotherapy comprising the stages of crisis support, crisis intervention and increase the adaptation layer. After a psychotherapy course levels of aggression (6,45±0,41), auto-aggression (of 9,68±0,67), disorders in the affective sphere (18,58±0,66) and impulsivity (of 4,23±0,30) decreased, which was manifested in increasing tolerance to emotional stress factors, control over their emotions and reduce their affective valence (p≤0,001). The expansion of interpersonal interaction, the increase of patients social activity, the blood relationships establishment (of 9,23±0,40) was observed.

  7. What are the 'ideal' features of an adrenaline (epinephrine) auto-injector in the treatment of anaphylaxis?

    PubMed

    Frew, A J

    2011-01-01

    Anaphylaxis is a systemic allergic reaction that often involves respiratory symptoms and cardiovascular collapse, which are potentially life-threatening if not treated promptly with intramuscular adrenaline. Owing to the unpredictable nature of anaphylaxis and accidental exposure to allergens (such as peanuts and shellfish), patients should be prescribed intramuscular adrenaline auto-injectors and carry these with them at all times. Patients also need to be able to use their auto-injectors correctly while under high stress, when an anaphylactic attack occurs. Despite this, an alarming number of patients fail to carry their auto-injectors and many patients, carers of children with known anaphylaxis and healthcare professionals do not know how to use the device correctly, despite having had training. Currently available auto-injector devices have various limitations that may impede their use in the management of anaphylaxis. There is also a lack of validated assessment criteria and regulatory requirements for new devices. This review describes the different delivery systems used in currently available auto-injectors and discusses the key barriers to the use of adrenaline auto-injectors, with the goal of identifying the 'ideal' features/characteristics of such devices in the emergency treatment of anaphylaxis that will ensure ease of use, portability and accurate delivery of a life-saving drug. © 2010 John Wiley & Sons A/S.

  8. Creating A Coordinated Autos/UAW Reporting System (CARS) For Evaluating Health Plan Performance,

    DTIC Science & Technology

    1999-09-01

    open enrollment materials, information was made available to employees on internal Web sites. The Greater Detroit Area Health Council also reported...RAND Creating A Coordinated Autos/UAW Reporting System (CARS) For Evaluating Health Plan Performance Elizabeth A. McGlynn, John Adams, Jennifer...Hicks, David Klein DRU-2123-FMC September 1999 Prepared for DaimlerChrysler, Ford Motor Company, General Motors, and the United Auto Workers

  9. AutoNR: an automated system that measures ECAP thresholds with the Nucleus Freedom cochlear implant via machine intelligence.

    PubMed

    Botros, Andrew; van Dijk, Bas; Killian, Matthijs

    2007-05-01

    AutoNRT is an automated system that measures electrically evoked compound action potential (ECAP) thresholds from the auditory nerve with the Nucleus Freedom cochlear implant. ECAP thresholds along the electrode array are useful in objectively fitting cochlear implant systems for individual use. This paper provides the first detailed description of the AutoNRT algorithm and its expert systems, and reports the clinical success of AutoNRT to date. AutoNRT determines thresholds by visual detection, using two decision tree expert systems that automatically recognise ECAPs. The expert systems are guided by a dataset of 5393 neural response measurements. The algorithm approaches threshold from lower stimulus levels, ensuring recipient safety during postoperative measurements. Intraoperative measurements use the same algorithm but proceed faster by beginning at stimulus levels much closer to threshold. When searching for ECAPs, AutoNRT uses a highly specific expert system (specificity of 99% during training, 96% during testing; sensitivity of 91% during training, 89% during testing). Once ECAPs are established, AutoNRT uses an unbiased expert system to determine an accurate threshold. Throughout the execution of the algorithm, recording parameters (such as implant amplifier gain) are automatically optimised when needed. In a study that included 29 intraoperative and 29 postoperative subjects (a total of 418 electrodes), AutoNRT determined a threshold in 93% of cases where a human expert also determined a threshold. When compared to the median threshold of multiple human observers on 77 randomly selected electrodes, AutoNRT performed as accurately as the 'average' clinician. AutoNRT has demonstrated a high success rate and a level of performance that is comparable with human experts. It has been used in many clinics worldwide throughout the clinical trial and commercial launch of Nucleus Custom Sound Suite, significantly streamlining the clinical procedures associated with

  10. AutoLens: Automated Modeling of a Strong Lens's Light, Mass and Source

    NASA Astrophysics Data System (ADS)

    Nightingale, J. W.; Dye, S.; Massey, Richard J.

    2018-05-01

    This work presents AutoLens, the first entirely automated modeling suite for the analysis of galaxy-scale strong gravitational lenses. AutoLens simultaneously models the lens galaxy's light and mass whilst reconstructing the extended source galaxy on an adaptive pixel-grid. The method's approach to source-plane discretization is amorphous, adapting its clustering and regularization to the intrinsic properties of the lensed source. The lens's light is fitted using a superposition of Sersic functions, allowing AutoLens to cleanly deblend its light from the source. Single component mass models representing the lens's total mass density profile are demonstrated, which in conjunction with light modeling can detect central images using a centrally cored profile. Decomposed mass modeling is also shown, which can fully decouple a lens's light and dark matter and determine whether the two component are geometrically aligned. The complexity of the light and mass models are automatically chosen via Bayesian model comparison. These steps form AutoLens's automated analysis pipeline, such that all results in this work are generated without any user-intervention. This is rigorously tested on a large suite of simulated images, assessing its performance on a broad range of lens profiles, source morphologies and lensing geometries. The method's performance is excellent, with accurate light, mass and source profiles inferred for data sets representative of both existing Hubble imaging and future Euclid wide-field observations.

  11. Cavity-enhanced Faraday rotation measurement with auto-balanced photodetection.

    PubMed

    Chang, Chia-Yu; Shy, Jow-Tsong

    2015-10-01

    Optical cavity enhancement for a tiny Faraday rotation is demonstrated with auto-balanced photodetection. This configuration is analyzed using the Jones matrix formalism. The resonant rotation signal is amplified, and thus, the angular sensitivity is improved. In the experiment, the air Faraday rotation is measured with an auto-balanced photoreceiver in single-pass and cavity geometries. The result shows that the measured Faraday rotation in the single-pass geometry is enhanced by a factor of 85 in the cavity geometry, and the sensitivity is improved to 7.54×10(-10)  rad Hz(-1/2), which agrees well with the Jones matrix analysis. With this verification, we propose an AC magnetic sensor whose magnetic sensitivity is expected to achieve 10  pT Hz(-1/2).

  12. [Correlation coefficient-based classification method of hydrological dependence variability: With auto-regression model as example].

    PubMed

    Zhao, Yu Xi; Xie, Ping; Sang, Yan Fang; Wu, Zi Yi

    2018-04-01

    Hydrological process evaluation is temporal dependent. Hydrological time series including dependence components do not meet the data consistency assumption for hydrological computation. Both of those factors cause great difficulty for water researches. Given the existence of hydrological dependence variability, we proposed a correlationcoefficient-based method for significance evaluation of hydrological dependence based on auto-regression model. By calculating the correlation coefficient between the original series and its dependence component and selecting reasonable thresholds of correlation coefficient, this method divided significance degree of dependence into no variability, weak variability, mid variability, strong variability, and drastic variability. By deducing the relationship between correlation coefficient and auto-correlation coefficient in each order of series, we found that the correlation coefficient was mainly determined by the magnitude of auto-correlation coefficient from the 1 order to p order, which clarified the theoretical basis of this method. With the first-order and second-order auto-regression models as examples, the reasonability of the deduced formula was verified through Monte-Carlo experiments to classify the relationship between correlation coefficient and auto-correlation coefficient. This method was used to analyze three observed hydrological time series. The results indicated the coexistence of stochastic and dependence characteristics in hydrological process.

  13. The History of the AutoChemist®: From Vision to Reality.

    PubMed

    Peterson, H E; Jungner, I

    2014-05-22

    This paper discusses the early history and development of a clinical analyser system in Sweden (AutoChemist, 1965). It highlights the importance of such high capacity system both for clinical use and health care screening. The device was developed to assure the quality of results and to automatically handle the orders, store the results in digital form for later statistical analyses and distribute the results to the patients' physicians by using the computer used for the analyser. The most important result of the construction of an analyser able to produce analytical results on a mass scale was the development of a mechanical multi-channel analyser for clinical laboratories that handled discrete sample technology and could prevent carry-over to the next test samples while incorporating computer technology to improve the quality of test results. The AutoChemist could handle 135 samples per hour in an 8-hour shift and up to 24 possible analyses channels resulting in 3,200 results per hour. Later versions would double this capacity. Some customers used the equipment 24 hours per day. With a capacity of 3,000 to 6,000 analyses per hour, pneumatic driven pipettes, special units for corrosive liquids or special activities, and an integrated computer, the AutoChemist system was unique and the largest of its kind for many years. Its follower - The AutoChemist PRISMA (PRogrammable Individually Selective Modular Analyzer) - was smaller in size but had a higher capacity. Both analysers established new standards of operation for clinical laboratories and encouraged others to use new technologies for building new analysers.

  14. AutoDockFR: Advances in Protein-Ligand Docking with Explicitly Specified Binding Site Flexibility

    PubMed Central

    Ravindranath, Pradeep Anand; Forli, Stefano; Goodsell, David S.; Olson, Arthur J.; Sanner, Michel F.

    2015-01-01

    Automated docking of drug-like molecules into receptors is an essential tool in structure-based drug design. While modeling receptor flexibility is important for correctly predicting ligand binding, it still remains challenging. This work focuses on an approach in which receptor flexibility is modeled by explicitly specifying a set of receptor side-chains a-priori. The challenges of this approach include the: 1) exponential growth of the search space, demanding more efficient search methods; and 2) increased number of false positives, calling for scoring functions tailored for flexible receptor docking. We present AutoDockFR–AutoDock for Flexible Receptors (ADFR), a new docking engine based on the AutoDock4 scoring function, which addresses the aforementioned challenges with a new Genetic Algorithm (GA) and customized scoring function. We validate ADFR using the Astex Diverse Set, demonstrating an increase in efficiency and reliability of its GA over the one implemented in AutoDock4. We demonstrate greatly increased success rates when cross-docking ligands into apo receptors that require side-chain conformational changes for ligand binding. These cross-docking experiments are based on two datasets: 1) SEQ17 –a receptor diversity set containing 17 pairs of apo-holo structures; and 2) CDK2 –a ligand diversity set composed of one CDK2 apo structure and 52 known bound inhibitors. We show that, when cross-docking ligands into the apo conformation of the receptors with up to 14 flexible side-chains, ADFR reports more correctly cross-docked ligands than AutoDock Vina on both datasets with solutions found for 70.6% vs. 35.3% systems on SEQ17, and 76.9% vs. 61.5% on CDK2. ADFR also outperforms AutoDock Vina in number of top ranking solutions on both datasets. Furthermore, we show that correctly docked CDK2 complexes re-create on average 79.8% of all pairwise atomic interactions between the ligand and moving receptor atoms in the holo complexes. Finally, we show that

  15. Auto-Configuration Protocols in Mobile Ad Hoc Networks

    PubMed Central

    Villalba, Luis Javier García; Matesanz, Julián García; Orozco, Ana Lucila Sandoval; Díaz, José Duván Márquez

    2011-01-01

    The TCP/IP protocol allows the different nodes in a network to communicate by associating a different IP address to each node. In wired or wireless networks with infrastructure, we have a server or node acting as such which correctly assigns IP addresses, but in mobile ad hoc networks there is no such centralized entity capable of carrying out this function. Therefore, a protocol is needed to perform the network configuration automatically and in a dynamic way, which will use all nodes in the network (or part thereof) as if they were servers that manage IP addresses. This article reviews the major proposed auto-configuration protocols for mobile ad hoc networks, with particular emphasis on one of the most recent: D2HCP. This work also includes a comparison of auto-configuration protocols for mobile ad hoc networks by specifying the most relevant metrics, such as a guarantee of uniqueness, overhead, latency, dependency on the routing protocol and uniformity. PMID:22163814

  16. Analysis of Air Traffic Track Data with the AutoBayes Synthesis System

    NASA Technical Reports Server (NTRS)

    Schumann, Johann Martin Philip; Cate, Karen; Lee, Alan G.

    2010-01-01

    The Next Generation Air Traffic System (NGATS) is aiming to provide substantial computer support for the air traffic controllers. Algorithms for the accurate prediction of aircraft movements are of central importance for such software systems but trajectory prediction has to work reliably in the presence of unknown parameters and uncertainties. We are using the AutoBayes program synthesis system to generate customized data analysis algorithms that process large sets of aircraft radar track data in order to estimate parameters and uncertainties. In this paper, we present, how the tasks of finding structure in track data, estimation of important parameters in climb trajectories, and the detection of continuous descent approaches can be accomplished with compact task-specific AutoBayes specifications. We present an overview of the AutoBayes architecture and describe, how its schema-based approach generates customized analysis algorithms, documented C/C++ code, and detailed mathematical derivations. Results of experiments with actual air traffic control data are discussed.

  17. Hierarchical auto-configuration addressing in mobile ad hoc networks (HAAM)

    NASA Astrophysics Data System (ADS)

    Ram Srikumar, P.; Sumathy, S.

    2017-11-01

    Addressing plays a vital role in networking to identify devices uniquely. A device must be assigned with a unique address in order to participate in the data communication in any network. Different protocols defining different types of addressing are proposed in literature. Address auto-configuration is a key requirement for self organizing networks. Existing auto-configuration based addressing protocols require broadcasting probes to all the nodes in the network before assigning a proper address to a new node. This needs further broadcasts to reflect the status of the acquired address in the network. Such methods incur high communication overheads due to repetitive flooding. To address this overhead, a new partially stateful address allocation scheme, namely Hierarchical Auto-configuration Addressing (HAAM) scheme is extended and proposed. Hierarchical addressing basically reduces latency and overhead caused during address configuration. Partially stateful addressing algorithm assigns addresses without the need for flooding and global state awareness, which in turn reduces the communication overhead and space complexity respectively. Nodes are assigned addresses hierarchically to maintain the graph of the network as a spanning tree which helps in effectively avoiding the broadcast storm problem. Proposed algorithm for HAAM handles network splits and merges efficiently in large scale mobile ad hoc networks incurring low communication overheads.

  18. MRT letter: Auto-fluorescence by human alveolar macrophages after in vitro exposure to air pollution particles.

    PubMed

    Ghio, Andrew J; Sangani, Rahul G; Brighton, Luisa E; Carson, John L

    2010-06-01

    Macrophages from smokers demonstrate an increased auto-fluorescence. Similarly, auto-fluorescence follows in vitro exposure of macrophages to cigarette smoke condensate (i.e., the particulate fraction of cigarette smoke). The composition of particles in cigarette smoke can be comparable to air pollution particles. We tested the postulate that macrophages exposed to air pollution particles could demonstrate auto-fluorescence. Healthy nonsmoking and healthy smoking volunteers (both 18-40 years of age) underwent fiberoptic bronchoscopy with bronchoalveolar lavage and alveolar macrophages isolated. Macrophages were incubated at 37 degrees C in 5% CO(2) with either PBS or 100 microg/mL particle for both 1 and 24 h. Particles included a residual oil fly ash, Mt. St. Helens volcanic ash, and ambient air particles collected from St. Louis, Missouri and Salt Lake City, Utah. At the end of incubation, 50 microL of the cell suspension was cytocentrifuged and examined at modes for viewing fluorescein isothiocyanate (FITC) and rhodamine fluorescence. Both emission source air pollution particles demonstrated FITC and rhodamine auto-fluorescence at 1 and 24 h, but the signal following incubation of the macrophages with oil fly ash appeared greater. Similarly, the ambient particles were associated with auto-fluorescence by the alveolar macrophages and this appeared to be dose-dependent. We conclude that exposure of macrophages to air pollution particles can be associated with auto-fluorescence in the FITC and rhodamine modes. c) 2009 Wiley-Liss, Inc

  19. An Integration of Math with Auto Technician Courses

    ERIC Educational Resources Information Center

    Valenzuela, Hector

    2012-01-01

    This article describes the development of the contextualized math, the course design, student teaching and daily interaction with the students, and the implementation aspects of the research project designed to develop contextualized mathematics and integrate it into the Auto Technician courses. The applied math curriculum was integrated into…

  20. 6. NORTH FRONT DETAIL, SHOWING AUTO ENTRANCE. VIEW TO SOUTHEAST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. NORTH FRONT DETAIL, SHOWING AUTO ENTRANCE. VIEW TO SOUTHEAST. - Commercial & Industrial Buildings, Key City Electric Street Railroad, Powerhouse & Storage Barn, Eighth & Washington Streets, Dubuque, Dubuque County, IA

  1. 6. WEST FRONT DETAIL, SHOWING AUTO ENTRANCE, WINDOWS AND MASONRY. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. WEST FRONT DETAIL, SHOWING AUTO ENTRANCE, WINDOWS AND MASONRY. VIEW TO NORTH. - Commercial & Industrial Buildings, Dubuque Oat Meal Mill Powerhouse, Seventh & Washington Streets, Dubuque, Dubuque County, IA

  2. Enhancing the auto-flocculation of photosynthetic bacteria to realize biomass recovery in brewery wastewater treatment.

    PubMed

    Lu, Haifeng; Dong, Shan; Zhang, Guangming; Han, Ting; Zhang, Yuanhui; Li, Baoming

    2018-02-15

    Photosynthetic bacteria (PSB) wastewater treatment technology can simultaneously realize wastewater purification and biomass production. The produced biomass contains high value-added products, which can be used in medical and agricultural industry. However, because of the small size and high electronegativity, PSB are hard to be collected from wastewater, which hampers the commercialization of PSB-based industrial processes. Auto-flocculation is a low cost, energy saving, non-toxic biomass collection method for microbiology. In this work, the influence factors with their optimal levels and mechanism for enhancing the auto-flocculation of PSB were investigated in pure cultivation medium. Then PSB auto-flocculation performance in real brewery wastewater was probed. Results showed that Na + concentration, pH and light intensity were three crucial factors except the initial inoculum sizes and temperature. In the pure medium cultivation system, the optimal condition for PSB auto-flocculation was as follows: pH was 9.5, inoculum size was 420 mg l -1 , Na + concentration was 0.067 mol l -1 , light intensity was 5000 lux, temperature was 30°C. Under the optimal condition, the auto-flocculation ratio and biomass recovery reached 85.0% and 1488 mg l -1 , which improved by 1.67-fold and 2.14-fold compared with the PSB enrichment cultivation conditions, respectively. Mechanism analysis showed that the protein/polysaccharides ratio and absolute Zeta potential value had a liner relationship. For the brewery wastewater treatment, under the above optimal condition, the chemical oxygen demand removal reached 94.3% with the auto-flocculation ratio and biomass recovery of 89.6% and 1510 mg l -1 , which increased 2.75-fold and 2.77-fold, respectively.

  3. Skin symptoms in bakery and auto body shop workers: associations with exposure and respiratory symptoms.

    PubMed

    Arrandale, Victoria; Meijster, Tim; Pronk, Anjoeka; Doekes, Gert; Redlich, Carrie A; Holness, D Linn; Heederik, Dick

    2013-02-01

    Despite the importance of skin exposure, studies of skin symptoms in relation to exposure and respiratory symptoms are rare. The goals of this study were to describe exposure-response relationships for skin symptoms, and to investigate associations between skin and respiratory symptoms in bakery and auto body shop workers. Data from previous studies of bakery and auto body shop workers were analyzed. Average exposure estimates for wheat allergen and isocyanates were used. Generalized linear models were constructed to describe the relationships between exposure and skin symptoms, as well as between skin and respiratory symptoms. Data from 723 bakery and 473 auto body shop workers were analyzed. In total, 5.3% of bakery and 6.1% of auto body shop workers were female; subjects' mean age was 39 and 38 years, respectively. Exposure-response relationships were observed in auto body shop workers for itchy or dry skin (PR 1.55, 95% CI 1.2-2.0) and work-related itchy skin (PR 1.97, 95% CI 1.2-3.3). A possible exposure-response relationship for work-related itchy skin in bakery workers did not reach statistical significance. In both groups, reporting skin symptoms was strongly and significantly associated with reporting respiratory symptoms, both work-related and non-work-related. Exposure-response relationships were observed for skin symptoms in auto body shop workers. The lack of significant exposure-response associations in bakery workers should be interpreted cautiously. Workers who reported skin symptoms were up to four times more likely to report respiratory symptoms. Improved awareness of both skin and respiratory outcomes in exposed workers is needed.

  4. Threshold-driven optimization for reference-based auto-planning

    NASA Astrophysics Data System (ADS)

    Long, Troy; Chen, Mingli; Jiang, Steve; Lu, Weiguo

    2018-02-01

    We study threshold-driven optimization methodology for automatically generating a treatment plan that is motivated by a reference DVH for IMRT treatment planning. We present a framework for threshold-driven optimization for reference-based auto-planning (TORA). Commonly used voxel-based quadratic penalties have two components for penalizing under- and over-dosing of voxels: a reference dose threshold and associated penalty weight. Conventional manual- and auto-planning using such a function involves iteratively updating the preference weights while keeping the thresholds constant, an unintuitive and often inconsistent method for planning toward some reference DVH. However, driving a dose distribution by threshold values instead of preference weights can achieve similar plans with less computational effort. The proposed methodology spatially assigns reference DVH information to threshold values, and iteratively improves the quality of that assignment. The methodology effectively handles both sub-optimal and infeasible DVHs. TORA was applied to a prostate case and a liver case as a proof-of-concept. Reference DVHs were generated using a conventional voxel-based objective, then altered to be either infeasible or easy-to-achieve. TORA was able to closely recreate reference DVHs in 5-15 iterations of solving a simple convex sub-problem. TORA has the potential to be effective for auto-planning based on reference DVHs. As dose prediction and knowledge-based planning becomes more prevalent in the clinical setting, incorporating such data into the treatment planning model in a clear, efficient way will be crucial for automated planning. A threshold-focused objective tuning should be explored over conventional methods of updating preference weights for DVH-guided treatment planning.

  5. Linking mileage to auto accident risk and urban form.

    DOT National Transportation Integrated Search

    2013-08-01

    Pricing auto insurance on a per-mile basis provides a beneficial, cost-based incentive to : reduce vehicle miles traveled compared with traditional rating plans that charge annual : premiums with little or no consideration of miles driven. : The rese...

  6. 3. PHOTOCOPY OF PHOTO CA. 1906 SHOWING WOODEN AUTO BODIES ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. PHOTOCOPY OF PHOTO CA. 1906 SHOWING WOODEN AUTO BODIES ON ASSEMBLY LINE, FROM COLLECTION OF HENRY BLOMMEL, CONNERSVILLE, INDIANA - Central Manufacturing Company, Eighteenth Street, Connersville, Fayette County, IN

  7. An example of auto-anti-A1 agglutinins.

    PubMed

    Wright, J; Lim, F C; Freedman, J

    1980-10-01

    The serum of an elderly man, group A, Le(a+b-), contained an IgM antibody that agglutinated his own cells and the cells of random group A1 donors. Over a period of 5 months, the titre of these auto-anti-A1 agglutinins was 4 at 22 degrees C.

  8. Inflation and deflation timing of the AutoCAT 2 WAVE intra-aortic balloon pump using the autoPilot mode in a clinical setting.

    PubMed

    Bakker, E W M; Visser, K; van der Wal, A; Kuiper, M A; Koopmans, M; Breedveld, R

    2012-09-01

    The primary goal of this observational clinical study was to register the occurrence of incorrect inflation and deflation timing of an intra-aortic balloon pump in autoPilot mode. The secondary goal was to identify possible causes of incorrect timing. During IABP assistance of 60 patients, every four hours a strip was printed with the IABP frequency set to 1:2. Strips were examined for timing discrepancies beyond 40 ms from the dicrotic notch (inflation) and the end of the diastolic phase (deflation). In this way, 320 printed strips were examined. A total of 52 strips (16%) showed incorrect timing. On 24 of these strips, the incorrect timing was called incidental, as it showed on only one or a few beats. The other 28 cases of erroneous timing were called consistent, as more than 50% of the beats on the strip showed incorrect timing. We observed arrhythmia in 69% of all cases of incorrect timing. When timing was correct, arrhythmia was found on 13 (5%) of 268 strips. A poor quality electrocardiograph (ECG) signal showed on 37% of all strips with incorrect timing and 11% of all strips with proper timing. We conclude that inflation and deflation timing of the IABP is not always correct when using the autoPilot mode. The quality of the ECG input signal and the occurrence of arrhythmia appear to be related to erroneous timing. Switching from autoPilot mode to operator mode may not always prevent incorrect timing.

  9. Diisocyanate-exposed auto body shop workers: a one-year follow-up.

    PubMed

    Redlich, C A; Stowe, M H; Coren, B A; Wisnewski, A V; Holm, C T; Cullen, M R

    2002-12-01

    Diisocyanates currently are the most commonly identified cause of occupational asthma in industrialized countries. Auto body shops, a common hexamethylene diisocyanate (HDI) exposure setting, are difficult to study due to their small size and episodic exposures. A 1-year follow-up was undertaken as an adjunct to the cross-sectional SPRAY study (Survey of Painters & Repairers of Auto bodies by Yale) to investigate the effects of HDI on auto body shop workers over time and whether or not the healthy worker effect may exist in this industry. Forty-eight workers from seven shops were re-contacted. Thirty-four subjects who stayed at the same shop and 11 who left their original shop participated. No statistically significant changes in physiology, symptoms, and immunologic responses from baseline to follow-up were noted. However, significant differences between those who left the shops and those who stayed were noted. Those who left were younger, less experienced in the industry, and more likely to have a history of asthma (23 vs. 3%; P < 0.05), bronchial hyper-responsiveness (23 vs. 9%), HDI-specific IgG (64 vs. 29%; P < 0.05), and HDI-specific proliferation (S.I. 2.0 vs. 1.3; P < 0.05). The differences in workers who stayed at their shop compared to those who left, combined with the low asthma prevalence and high job turnover rate, all suggest that a healthy worker effect may exist in the auto body industry, and may in part account for the low prevalence of asthma noted in SPRAY and other cross-sectional studies of diisocyante workers. Copyright 2002 Wiley-Liss, Inc.

  10. A study experiment of auto idle application in the excavator engine performance

    NASA Astrophysics Data System (ADS)

    Purwanto, Wawan; Maksum, Hasan; Putra, Dwi Sudarno; Azmi, Meri; Wahyudi, Retno

    2016-03-01

    The purpose of this study was to analyze the effect of applying auto idle to excavator engine performance, such as machine unitization and fuel consumption in Excavator. Steps to be done are to modify the system JA 44 and 67 in Vehicle Electronic Control Unit (V-ECU). The modifications will be obtained from the pattern of the engine speed. If the excavator attachment is not operated, the engine speed will return to the idle speed automatically. From the experiment results the auto idle reduces fuel consumption in excavator engine.

  11. A study experiment of auto idle application in the excavator engine performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Purwanto, Wawan, E-mail: wawan5527@gmail.com; Maksum, Hasan; Putra, Dwi Sudarno, E-mail: dwisudarnoputra@ft.unp.ac.id

    2016-03-29

    The purpose of this study was to analyze the effect of applying auto idle to excavator engine performance, such as machine unitization and fuel consumption in Excavator. Steps to be done are to modify the system JA 44 and 67 in Vehicle Electronic Control Unit (V-ECU). The modifications will be obtained from the pattern of the engine speed. If the excavator attachment is not operated, the engine speed will return to the idle speed automatically. From the experiment results the auto idle reduces fuel consumption in excavator engine.

  12. Pick-N-Pull Auto Dismantlers, Kansas City, LLC Inc.

    EPA Pesticide Factsheets

    The EPA is providing notice of a proposed Administrative Penalty Assessment against Pick-N-Pull Auto Dismantlers, Kansas City, LLC, a subsidiary of Schnitzer Steel Industries, Inc., for alleged violations at its facilities at 8012 East Truman Rd., Kansas C

  13. Kepler AutoRegressive Planet Search: Motivation & Methodology

    NASA Astrophysics Data System (ADS)

    Caceres, Gabriel; Feigelson, Eric; Jogesh Babu, G.; Bahamonde, Natalia; Bertin, Karine; Christen, Alejandra; Curé, Michel; Meza, Cristian

    2015-08-01

    The Kepler AutoRegressive Planet Search (KARPS) project uses statistical methodology associated with autoregressive (AR) processes to model Kepler lightcurves in order to improve exoplanet transit detection in systems with high stellar variability. We also introduce a planet-search algorithm to detect transits in time-series residuals after application of the AR models. One of the main obstacles in detecting faint planetary transits is the intrinsic stellar variability of the host star. The variability displayed by many stars may have autoregressive properties, wherein later flux values are correlated with previous ones in some manner. Auto-Regressive Moving-Average (ARMA) models, Generalized Auto-Regressive Conditional Heteroskedasticity (GARCH), and related models are flexible, phenomenological methods used with great success to model stochastic temporal behaviors in many fields of study, particularly econometrics. Powerful statistical methods are implemented in the public statistical software environment R and its many packages. Modeling involves maximum likelihood fitting, model selection, and residual analysis. These techniques provide a useful framework to model stellar variability and are used in KARPS with the objective of reducing stellar noise to enhance opportunities to find as-yet-undiscovered planets. Our analysis procedure consisting of three steps: pre-processing of the data to remove discontinuities, gaps and outliers; ARMA-type model selection and fitting; and transit signal search of the residuals using a new Transit Comb Filter (TCF) that replaces traditional box-finding algorithms. We apply the procedures to simulated Kepler-like time series with known stellar and planetary signals to evaluate the effectiveness of the KARPS procedures. The ARMA-type modeling is effective at reducing stellar noise, but also reduces and transforms the transit signal into ingress/egress spikes. A periodogram based on the TCF is constructed to concentrate the signal

  14. Auto Mechanics. Criterion-Referenced Test (CRT) Item Bank.

    ERIC Educational Resources Information Center

    Tannehill, Dana, Ed.

    This document contains 546 criterion-referenced multiple choice and true or false test items for a course in auto mechanics. The test item bank is designed to work with both the Vocational Instructional Management System (VIMS) and Vocational Administrative Management System (VAMS) in Missouri. The items are grouped into 35 units covering the…

  15. The Global Product: Internationalization of the Auto Industry.

    ERIC Educational Resources Information Center

    Stanford Univ., CA. Stanford Program on International and Cross Cultural Education.

    This secondary level unit, designed for use in a social studies or introductory economics course, has students participate in decision-making activities about global auto production. Although Japan-United States interaction is emphasized, the concepts, terms and activities employed in the unit apply to other countries as well. The unit includes 11…

  16. Epinephrine Auto-Injector Versus Drawn Up Epinephrine for Anaphylaxis Management: A Scoping Review.

    PubMed

    Chime, Nnenna O; Riese, Victoria G; Scherzer, Daniel J; Perretta, Julianne S; McNamara, LeAnn; Rosen, Michael A; Hunt, Elizabeth A

    2017-08-01

    Anaphylaxis is a life-threatening event. Most clinical symptoms of anaphylaxis can be reversed by prompt intramuscular administration of epinephrine using an auto-injector or epinephrine drawn up in a syringe and delays and errors may be fatal. The aim of this scoping review is to identify and compare errors associated with use of epinephrine drawn up in a syringe versus epinephrine auto-injectors in order to assist hospitals as they choose which approach minimizes risk of adverse events for their patients. PubMed, Embase, CINAHL, Web of Science, and the Cochrane Library were searched using terms agreed to a priori. We reviewed human and simulation studies reporting errors associated with the use of epinephrine in anaphylaxis. There were multiple screening stages with evolving feedback. Each study was independently assessed by two reviewers for eligibility. Data were extracted using an instrument modeled from the Zaza et al instrument and grouped into themes. Three main themes were noted: 1) ergonomics, 2) dosing errors, and 3) errors due to route of administration. Significant knowledge gaps in the operation of epinephrine auto-injectors among healthcare providers, patients, and caregivers were identified. For epinephrine in a syringe, there were more frequent reports of incorrect dosing and erroneous IV administration with associated adverse cardiac events. For the epinephrine auto-injector, unintentional administration to the digit was an error reported on multiple occasions. This scoping review highlights knowledge gaps and a diverse set of errors regardless of the approach to epinephrine preparation during management of anaphylaxis. There are more potentially life-threatening errors reported for epinephrine drawn up in a syringe than with the auto-injectors. The impact of these knowledge gaps and potentially fatal errors on patient outcomes, cost, and quality of care is worthy of further investigation.

  17. Auto-antibodies and Autoimmune Disease during Treatment of Children with Chronic Hepatitis C

    PubMed Central

    Molleston, Jean P.; Mellman, William; Narkewicz, Michael R.; Balistreri, William F.; Gonzalez-Peralta, Regino P.; Jonas, Maureen M.; Lobritto, Steven J.; Mohan, Parvathi; Murray, Karen F.; Njoku, Dolores; Rosenthal, Philip; Barton, Bruce A.; Talor, Monica V.; Cheng, Irene; Schwarz, Kathleen B.; Haber, Barbara A.

    2012-01-01

    Objectives Auto-antibodies were studied in a well-characterized cohort of children with chronic hepatitis C (CHC) during treatment with PEG-IFN and ribavirin to assess the relationship to treatment and development of autoimmune disease. Methods 114 children (5–17 years), previously screened for the presence of high titer autoantibodies, were randomized to Peg-IFN with or without ribavirin. Anti-nuclear (ANA), anti-liver-kidney-microsomal (LKM), anti-thyroglobulin (TG), anti-thyroid peroxidase (TPO), insulin (IA2), anti-glutamic acid decarboxylase (GAD) antibodies were measured after trial completion using frozen sera. Results At baseline,19% had auto-antibodies: ANA (8%), LKM (4%), and GAD (4%). At 24 and 72 weeks (24 weeks after treatment completion), 23% and 26% had auto-antibodies (p=0.50, 0.48 compared to baseline). One child developed diabetes and two hypothyroidism during treatment; none developed autoimmune hepatitis. At 24 weeks, the incidence of flu-like symptoms, gastrointestinal symptoms, and headaches were 42%, 8% and 19% in those with auto-antibodies vs. 52%, 17%, and 26% in those without (p=0.18, 0.36, and 0.20, respectively). In children with negative HCV PCR at 24 weeks, there was no difference in the rate of early virologic response /sustained virologic response respectively in those with auto-antibodies 76%/69%, vs 58%/65% in those without (p=0.48). Conclusions Despite screening, we found autoantibodies commonly at baseline, during treatment for CHC and after. The presence of antibodies did not correlate with viral response, side effects, or autoimmune hepatitis. Neither screening nor archived samples assayed for thyroid and diabetes-related antibodies identified the 3 subjects who developed overt autoimmune disease, diabetes (1) and hypothyroidism (2). PMID:23439301

  18. AutoRoute Rapid Flood Inundation Model

    DTIC Science & Technology

    2013-03-01

    Res. 33(2): 309-319. U.S. Army Engineer Hydrologic Engineering Center. 2010. “ HEC - RAS : River Analysis System, User’s Manual, Version 4.1.” Davis...cross-section data does not exist. As such, the AutoRoute model is not meant to be as accurate as models such as HEC - RAS (U.S. Army Engineer...such as HEC - RAS assume that the defined low point of cross sections must be connected. However, in this approach the channel is assumed to be defined

  19. When should we perform a repeat training on adrenaline auto-injector use for physician trainees?

    PubMed

    Topal, E; Bakirtas, A; Yilmaz, O; Karagol, I H E; Arga, M; Demirsoy, M S; Turktas, I

    2014-01-01

    Studies demonstrate that both doctors and patients may use adrenaline auto-injector improperly and the usage skills are improved by training. In this study, we aimed to determine the appropriate frequency of training to maintain skills for adrenaline auto-injector use. We invited all interns of 2011-2012 training period. At baseline, all participants were given theoretical and practical training on adrenaline auto-injector use. The participants were randomly assigned into two groups. We asked those in group 1 to demonstrate the use of adrenaline auto-injector trainer in the third month and those in group 2 in the sixth month. One hundred and sixty interns were enrolled. Compared with the beginning score, demonstration of skills at all the steps and total scores did not change for the group tested in the third month (p=0.265 and p=0.888, respectively). However; for the group examined in the sixth month; the demonstration of skills for proper use of the auto-injector at all steps and the mean time to administer adrenaline decreased (p=0.018 and p<0.001, respectively). Besides, the group which was tested in the third month was better than the group which was tested in the sixth month in terms of demonstrating all steps (p=0.014), the total score (p=0.019), mean time of change to administer adrenaline (p<0.001) and presumptive self-injection into thumb (p=0.029). Auto-injector usage skills of physician trainees decrease after the sixth month and are better in those who had skill reinforcement at 3 months, suggesting continued education and skill reinforcement may be useful. Copyright © 2013 SEICAP. Published by Elsevier Espana. All rights reserved.

  20. Designing for auto safety

    NASA Technical Reports Server (NTRS)

    Driver, E. T.

    1971-01-01

    Safety design features in the motor vehicle and highway construction fields result from systems analysis approach to prevent or lessen death, injury, and property damage results. Systems analysis considers the prevention of crashes, increased survivability in crashes, and prompt medical attention to injuries as well as other postcrash salvage measures. The interface of these system elements with the driver, the vehicle, and the environment shows that action on the vehicle system produces the greatest safety payoff through design modifications. New and amended safety standards developed through hazard analysis technique improved accident statistics in the 70'; these regulations include driver qualifications and countermeasures to identify the chronic drunken driver who is involved in more than two-thirds of all auto deaths.

  1. Biochemical and Ultrastructural Changes in Sida cordifolia L. and Catharanthus roseus L. to Auto Pollution.

    PubMed

    Verma, Vijeta; Chandra, Neelam

    2014-01-01

    Auto pollution is the by-product of our mechanized mobility, which adversely affects both plant and human life. However, plants growing in the urban locations provide a great respite to us from the brunt of auto pollution by absorbing the pollutants at their foliar surface. Foliar surface configuration and biochemical changes in plant species, namely, Sida cordifolia L. and Catharanthus roseus L. grown at roadside (polluted site 1, Talkatora; polluted site 2, Charbagh) in Lucknow city and in the garden of the university campus, which has been taken as reference site, were investigated. It was observed that air pollution caused by auto exhaust showed marked alterations in photosynthetic pigments (chlorophyll, carotenoid, and phaeophytin), and relative water content was reduced while antioxidative enzymes like catalase and peroxidase were found to be enhanced. The changes in the foliar configuration reveal marked alteration in epidermal traits, with decreased number of stomata, stomatal indices, and epidermal cells per unit area, while length and breadth of stomata and epidermal cells were found to be increased in leaves samples wich can be used as biomarkers of auto pollution.

  2. Correlation among auto-refractor, wavefront aberration, and subjective manual refraction

    NASA Astrophysics Data System (ADS)

    Li, Qi; Ren, Qiushi

    2005-01-01

    Three optometry methods which include auto-refractor, wavefront aberrometer and subjective manual refraction were studied and compared in measuring low order aberrations of 60 people"s 117 normal eyes. Paired t-test and linear regression were used to study these three methods" relationship when measuring myopia with astigmatism. In order to make the analysis more clear, we divided the 117 normal eyes into different groups according to their subjective manual refraction and redid the statistical analysis. Correlations among three methods show significant in sphere, cylinder and axis in all groups, with sphere"s correlation coefficients largest(R>0.98, P<0.01) and cylinder"s smallest (0.900.01). Auto-refractor had significant change from the other two methods when measuring cylinder (P<0.01). The results after grouping differed a little from the analysis among total people. Although three methods showed significant change from each other in certain parameters, the amplitude of these differences were not large, which indicated that the coherence of auto-refractor, wavefront aberrometer and subjective refraction is good. However, we suggested that wavefront aberration measurement could be a good starting point of optometry, subjective refraction is still necessary for refinement.

  3. PERI - Auto-tuning Memory Intensive Kernels for Multicore

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bailey, David H; Williams, Samuel; Datta, Kaushik

    2008-06-24

    We present an auto-tuning approach to optimize application performance on emerging multicore architectures. The methodology extends the idea of search-based performance optimizations, popular in linear algebra and FFT libraries, to application-specific computational kernels. Our work applies this strategy to Sparse Matrix Vector Multiplication (SpMV), the explicit heat equation PDE on a regular grid (Stencil), and a lattice Boltzmann application (LBMHD). We explore one of the broadest sets of multicore architectures in the HPC literature, including the Intel Xeon Clovertown, AMD Opteron Barcelona, Sun Victoria Falls, and the Sony-Toshiba-IBM (STI) Cell. Rather than hand-tuning each kernel for each system, we developmore » a code generator for each kernel that allows us to identify a highly optimized version for each platform, while amortizing the human programming effort. Results show that our auto-tuned kernel applications often achieve a better than 4X improvement compared with the original code. Additionally, we analyze a Roofline performance model for each platform to reveal hardware bottlenecks and software challenges for future multicore systems and applications.« less

  4. Fuel magnetization without external field coils (AutoMag)

    NASA Astrophysics Data System (ADS)

    Slutz, Stephen; Jennings, Christopher; Awe, Thomas; Shipley, Gabe; Lamppa, Derek; McBride, Ryan

    2016-10-01

    Magnetized Liner Inertial Fusion (MagLIF) has produced fusion-relevant plasma conditions on the Z accelerator where the fuel was magnetized using external field coils. We present a novel concept that does not need external field coils. This concept (AutoMag) magnetizes the fuel during the early part of the drive current by using a composite liner with helical conduction paths separated by insulating material. The drive is designed so the current rises slowly enough to avoid electrical breakdown of the insulators until a sufficiently strong magnetic field is established. Then the current rises more quickly, which causes the insulators to break down allowing the drive current to follow an axial path and implode the liner. Low inductance magnetically insulated power feeds can be used with AutoMag to increase the drive current without interfering with diagnostic access. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  5. A proposed framework for consensus-based lung tumour volume auto-segmentation in 4D computed tomography imaging

    NASA Astrophysics Data System (ADS)

    Martin, Spencer; Brophy, Mark; Palma, David; Louie, Alexander V.; Yu, Edward; Yaremko, Brian; Ahmad, Belal; Barron, John L.; Beauchemin, Steven S.; Rodrigues, George; Gaede, Stewart

    2015-02-01

    This work aims to propose and validate a framework for tumour volume auto-segmentation based on ground-truth estimates derived from multi-physician input contours to expedite 4D-CT based lung tumour volume delineation. 4D-CT datasets of ten non-small cell lung cancer (NSCLC) patients were manually segmented by 6 physicians. Multi-expert ground truth (GT) estimates were constructed using the STAPLE algorithm for the gross tumour volume (GTV) on all respiratory phases. Next, using a deformable model-based method, multi-expert GT on each individual phase of the 4D-CT dataset was propagated to all other phases providing auto-segmented GTVs and motion encompassing internal gross target volumes (IGTVs) based on GT estimates (STAPLE) from each respiratory phase of the 4D-CT dataset. Accuracy assessment of auto-segmentation employed graph cuts for 3D-shape reconstruction and point-set registration-based analysis yielding volumetric and distance-based measures. STAPLE-based auto-segmented GTV accuracy ranged from (81.51  ±  1.92) to (97.27  ±  0.28)% volumetric overlap of the estimated ground truth. IGTV auto-segmentation showed significantly improved accuracies with reduced variance for all patients ranging from 90.87 to 98.57% volumetric overlap of the ground truth volume. Additional metrics supported these observations with statistical significance. Accuracy of auto-segmentation was shown to be largely independent of selection of the initial propagation phase. IGTV construction based on auto-segmented GTVs within the 4D-CT dataset provided accurate and reliable target volumes compared to manual segmentation-based GT estimates. While inter-/intra-observer effects were largely mitigated, the proposed segmentation workflow is more complex than that of current clinical practice and requires further development.

  6. A proposed framework for consensus-based lung tumour volume auto-segmentation in 4D computed tomography imaging.

    PubMed

    Martin, Spencer; Brophy, Mark; Palma, David; Louie, Alexander V; Yu, Edward; Yaremko, Brian; Ahmad, Belal; Barron, John L; Beauchemin, Steven S; Rodrigues, George; Gaede, Stewart

    2015-02-21

    This work aims to propose and validate a framework for tumour volume auto-segmentation based on ground-truth estimates derived from multi-physician input contours to expedite 4D-CT based lung tumour volume delineation. 4D-CT datasets of ten non-small cell lung cancer (NSCLC) patients were manually segmented by 6 physicians. Multi-expert ground truth (GT) estimates were constructed using the STAPLE algorithm for the gross tumour volume (GTV) on all respiratory phases. Next, using a deformable model-based method, multi-expert GT on each individual phase of the 4D-CT dataset was propagated to all other phases providing auto-segmented GTVs and motion encompassing internal gross target volumes (IGTVs) based on GT estimates (STAPLE) from each respiratory phase of the 4D-CT dataset. Accuracy assessment of auto-segmentation employed graph cuts for 3D-shape reconstruction and point-set registration-based analysis yielding volumetric and distance-based measures. STAPLE-based auto-segmented GTV accuracy ranged from (81.51  ±  1.92) to (97.27  ±  0.28)% volumetric overlap of the estimated ground truth. IGTV auto-segmentation showed significantly improved accuracies with reduced variance for all patients ranging from 90.87 to 98.57% volumetric overlap of the ground truth volume. Additional metrics supported these observations with statistical significance. Accuracy of auto-segmentation was shown to be largely independent of selection of the initial propagation phase. IGTV construction based on auto-segmented GTVs within the 4D-CT dataset provided accurate and reliable target volumes compared to manual segmentation-based GT estimates. While inter-/intra-observer effects were largely mitigated, the proposed segmentation workflow is more complex than that of current clinical practice and requires further development.

  7. Study of AUTO-LION (Automatic Lighting Rumpon) on Fisheries of Stationary Lift Net in Semarang, Central Java

    NASA Astrophysics Data System (ADS)

    Chairunnisa, S.; Setiawan, N.; Irkham; Ekawati, K.; Anwar, A.; Fitri, A. DP

    2018-02-01

    Fish Aggregation Device (FAD) is a fishing tool that serves to collect fish at a place to facilitate fishermen in the process of fishing. The use of light is also proven to help the process of fishing at night. AUTO-LION (Automatic Lighting Rumpon) is a FADs innovation equipped with fish-eating sound and solar-powered lights that can be activated automatically when it is dark or nighttime.The purpose of this study was to determine the effect of AUTO-LION use on fishermen catch. The research method used is experimental fishing.The research was conducted on May 2017 on the stationary lift net in Semarang Waters. The results showed the catch as much as 10.55 kg without the use of AUTO-LION, 15.05 kg on the use of FADs, 19.08 kg on the use of FADs with sound, 27.04 kg on the use of FADs with light, and 40.01 kg on the use of AUTO-LION. Based on these results it can be seen that the use of AUTO-LION can increase the catch of fishermen, especially when the light is activated.

  8. Accuracy of a novel auto-CPAP device to evaluate the residual apnea-hypopnea index in patients with obstructive sleep apnea.

    PubMed

    Nigro, Carlos Alberto; González, Sergio; Arce, Anabella; Aragone, María Rosario; Nigro, Luciana

    2015-05-01

    Patients under treatment with continuous positive airway pressure (CPAP) may have residual sleep apnea (RSA). The main objective of our study was to evaluate a novel auto-CPAP for the diagnosis of RSA. All patients referred to the sleep laboratory to undergo CPAP polysomnography were evaluated. Patients treated with oxygen or noninvasive ventilation and split-night polysomnography (PSG), PSG with artifacts, or total sleep time less than 180 min were excluded. The PSG was manually analyzed before generating the automatic report from auto-CPAP. PSG variables (respiratory disturbance index (RDI), obstructive apnea index, hypopnea index, and central apnea index) were compared with their counterparts from auto-CPAP through Bland-Altman plots and intraclass correlation coefficient. The diagnostic accuracy of autoscoring from auto-CPAP using different cutoff points of RDI (≥5 and 10) was evaluated by the receiver operating characteristics (ROCs) curve. The study included 114 patients (24 women; mean age and BMI, 59 years old and 33 kg/m(2); RDI and apnea/hypopnea index (AHI)-auto median, 5 and 2, respectively). The average difference between the AHI-auto and the RDI was -3.5 ± 3.9. The intraclass correlation coefficient (ICC) between the total number of central apneas, obstructive, and hypopneas between the PSG and the auto-CPAP were 0.69, 0.16, and 0.15, respectively. An AHI-auto >2 (RDI ≥ 5) or >4 (RDI ≥ 10) had an area under the ROC curve, sensitivity, specificity, positive likelihood ratio, and negative for diagnosis of residual sleep apnea of 0.84/0.89, 84/81%, 82/91%, 4.5/9.5, and 0.22/0.2, respectively. The automatic analysis from auto-CPAP (S9 Autoset) showed a good diagnostic accuracy to identify residual sleep apnea. The absolute agreement between PSG and auto-CPAP to classify the respiratory events correctly varied from very low (obstructive apneas, hypopneas) to moderate (central apneas).

  9. Auto-aggregation properties of a novel aerobic denitrifier Enterobacter sp. strain FL.

    PubMed

    Wang, Xia; An, Qiang; Zhao, Bin; Guo, Jin Song; Huang, Yuan Sheng; Tian, Meng

    2018-02-01

    Enterobacter sp. strain FL was newly isolated from activated sludge and exhibited significant capability of auto-aggregation as well as aerobic denitrification. The removal efficiencies of NO 3 - -N, total nitrogen (TN), and TOC by strain FL in batch culture reached 94.6, 63.9, and 72.5% in 24 h, respectively. The production of N 2 O and N 2 in the presence of oxygen demonstrated the occurrence of aerobic denitrification. The auto-aggregation index of strain FL reached 54.3%, suggesting a high tendency that the cells would agglomerate into aggregates. The production of extracellular polymeric substances (EPSs), which were mainly composed of proteins followed by polysaccharides, was considered to be related to the cell aggregation according to Fourier transform infrared (FT-IR) and confocal laser scanning microscopy (CLSM). The proteins in EPS were evenly and tightly combined to cells and altered the protein secondary structures of cell surface from random coils to β-sheets and three-turn helices. The alteration of protein secondary structures of cell surface caused by the proteins in EPS might play a dominant role in the auto-aggregation of strain FL. To further assess the feasibility of strain FL for synthetic wastewater treatment, a sequencing batch reactor (SBR), solely inoculated with strain FL, was conducted. During the 16 running cycles, the removal efficiency of NO 3 - -N was 90.2-99.7% and the auto-aggregation index was stabilized at 35.0-41.5%. The EPS promoted the biomass of strain FL to aggregate in the SBR.

  10. Auto-flotation of heterocyst enables the efficient production of renewable energy in cyanobacteria.

    PubMed

    Chen, Ming; Li, Jihong; Zhang, Lei; Chang, Sandra; Liu, Chen; Wang, Jianlong; Li, Shizhong

    2014-02-06

    Utilizing cyanobacteria as a bioenergy resource is difficult due to the cost and energy consuming harvests of microalgal biomass. In this study, an auto-floating system was developed by increasing the photobiological H2 production in the heterocysts of filamentous cyanobacteria. An amount of 1.0 μM of diuron, which inhibited O2 production in cyanobacteria, resulted in a high rate of H2 production in heterocysts. The auto-floating process recovered 91.71% ± 1.22 of the accumulated microalgal biomass from the liquid media. Quantification analysis revealed that 0.72-1.10 μmol H2 per mg dry weight microalgal biomass was necessary to create this auto-floating system. Further bio-conversion by using anaerobic digestion converted the harvested microalgal biomass into biogas. Through this novel coupled system of photobiological H2 production and anaerobic digestion, a high level of light energy conversion efficiency from solar energy to bioenergy was attained with the values of 3.79% ± 0.76.

  11. Identification and tracking of hairpin vortex auto-generation in turbulent wall-bounded flow

    NASA Astrophysics Data System (ADS)

    Huang, Yangzi; Green, Melissa

    2016-11-01

    Hairpin vortices have been widely accepted as component structures of turbulent boundary layers. Their properties (size, vorticity, energy) and dynamic phenomena (origin, growth, breakdown) have been shown to correlate to the complex, multi-scaled turbulent motions observed in both experiments and simulations. As established in the literature, the passage of a hairpin vortex creates a wall-normal ejection of fluid, which encounters the high-speed freestream resulting in near-wall shear and increased drag. A previously generated simulation of an isolated hairpin vortex is used to study the auto-generation of a secondary vortex structure. Eulerian methods such as the Q criterion and Γ2 function, as well as Lagrangian methods are used to visualize the three-dimensional hairpin vortices and the auto-generation process. The circulation development and wall-normal location of both primary and secondary hairpin heads are studied to determine if there is a correlation between the strength and height of the primary hairpin vortex with the secondary hairpin vortex auto-generation.

  12. Recycling of auto shredder residue.

    PubMed

    Nourreddine, Menad

    2007-01-31

    Currently, about 75% of end-of-life vehicle's (ELV) total weight is recycled in EU countries. The remaining 25%, which is called auto shredder residues (ASR) or auto fluff, is disposed of as landfill because of its complexity. It is a major challenge to reduce this percentage of obsolete cars. The European draft directive states that by the year 2006, only 15% of the vehicle's weight can be disposed of at landfill sites and by 2015, this will be reduced to 5%. The draft directive states that a further 10% can be incinerated. The quantities of shredder fluff are likely to increase in the coming years. This is because of the growing number of cars being scrapped, coupled with the increase in the amount of plastics used in cars. In Sweden, some current projects are focusing on recycling of ASR material. In this paper some different alternatives for using this material are reported. The hypothetical injection of ASR into a blast furnace concentrating on ASR's effect to some blast furnace (BF) parameters has been completed using a blast furnace mass balance model. As a result, in principle, ASR can be used as reducing agent in the BF process if certain conditions are met. The particle size of ASR material must be controlled to ensure optimal gasification of the material in the raceway. Regarding the chemical composition of ASR, the non-ferrous content can affect the pig iron quality, which is difficult to rectify at a later point. The most attractive recycling alternative is to use the products obtained from pyrolysis of ASR in appropriate metallurgical processes.

  13. Chemotaxis and auto-chemotaxis of self-propelling artificial droplet swimmers

    NASA Astrophysics Data System (ADS)

    Jin, Chenyu; Krueger, Carsten; Maass, Corinna

    Chemotaxis and auto-chemotaxis are key mechanisms in the dynamics of micro-organisms, e.g. in the acquisition of nutrients and in the communication between individuals, influencing the collective behavior. However, chemical signalling and the natural environment of biological swimmers are generally complex, making them hard to access analytically. Simple experimental systems showing similar features could provide vital insights. We present such a swimmer system, as well as controlled assays to study chemotactic effects quantitatively and reproducibly. In our experiments, we let auto-chemotactic droplet swimmers pass through bifurcating microfluidic channels and record anticorrelations between the branch choices of consecutive droplets. We present an analytical model based on balancing stochastic forces versus a diffusing chemical gradient matching the experimental data. supported by the DFG SPP 1726 ''Microswimmers'' and the MaxSynBio network.

  14. Automatic image fusion of real-time ultrasound with computed tomography images: a prospective comparison between two auto-registration methods.

    PubMed

    Cha, Dong Ik; Lee, Min Woo; Kim, Ah Yeong; Kang, Tae Wook; Oh, Young-Taek; Jeong, Ja-Yeon; Chang, Jung-Woo; Ryu, Jiwon; Lee, Kyong Joon; Kim, Jaeil; Bang, Won-Chul; Shin, Dong Kuk; Choi, Sung Jin; Koh, Dalkwon; Seo, Bong Koo; Kim, Kyunga

    2017-11-01

    Background A major drawback of conventional manual image fusion is that the process may be complex, especially for less-experienced operators. Recently, two automatic image fusion techniques called Positioning and Sweeping auto-registration have been developed. Purpose To compare the accuracy and required time for image fusion of real-time ultrasonography (US) and computed tomography (CT) images between Positioning and Sweeping auto-registration. Material and Methods Eighteen consecutive patients referred for planning US for radiofrequency ablation or biopsy for focal hepatic lesions were enrolled. Image fusion using both auto-registration methods was performed for each patient. Registration error, time required for image fusion, and number of point locks used were compared using the Wilcoxon signed rank test. Results Image fusion was successful in all patients. Positioning auto-registration was significantly faster than Sweeping auto-registration for both initial (median, 11 s [range, 3-16 s] vs. 32 s [range, 21-38 s]; P < 0.001] and complete (median, 34.0 s [range, 26-66 s] vs. 47.5 s [range, 32-90]; P = 0.001] image fusion. Registration error of Positioning auto-registration was significantly higher for initial image fusion (median, 38.8 mm [range, 16.0-84.6 mm] vs. 18.2 mm [6.7-73.4 mm]; P = 0.029), but not for complete image fusion (median, 4.75 mm [range, 1.7-9.9 mm] vs. 5.8 mm [range, 2.0-13.0 mm]; P = 0.338]. Number of point locks required to refine the initially fused images was significantly higher with Positioning auto-registration (median, 2 [range, 2-3] vs. 1 [range, 1-2]; P = 0.012]. Conclusion Positioning auto-registration offers faster image fusion between real-time US and pre-procedural CT images than Sweeping auto-registration. The final registration error is similar between the two methods.

  15. An Analysis of the Auto Body Repair Occupation.

    ERIC Educational Resources Information Center

    Stranke, Edward J.; Speck, Samuel R.

    The general purpose of the occupational analysis is to provide workable, basic information dealing with the many and varied duties performed in the auto body mechanic occupation. The document opens with a brief introduction followed by a job description. The bulk of the document is presented in table form. Eleven duties are broken down into a…

  16. Production of functional sperm by subcutaneous auto-grafting of immature testes in rainbow trout.

    PubMed

    Hayashi, Makoto; Sakuma, Daika; Yoshizaki, Goro

    2018-02-01

    Sexually mature individuals are indispensable for breeding programs. Salmonids require a long period before reaching sexual maturity, so we aimed to shorten the period required to obtain functional sperm by grafting immature testicular fragments into mature recipients, which we predicted would allow the grafted testicular fragments to skip the long pre-pubertal period. First, we demonstrated successful subcutaneous auto-grafting of testicular fragments in rainbow trout. Unilateral testectomy was performed, and the isolated immature testicular fragment was auto-grafted into the subcutaneous space along the back of recipient fish. The grafted testicular fragments developed synchronously with the recipients' testis remaining in its body cavity, and both eventually produced functional sperm. Next, immature testicular fragments were auto-grafted into the subcutaneous space of sexually mature males. We achieved this, without immune rejection, by isolating and cryopreserving testes from immature fish, and rearing these unilaterally testectomized fish until sexual maturity. The cryopreserved testes were then auto-grafted into the original, now spermiating fish. The grated immature testicular fragments differentiated and produced functional sperm within 5 months after grafting. By combining this grafting method with a technique to avoid immune rejection, we expect to develop a practical method for producing sperm in a shorter period in salmonids. © 2017 Wiley Periodicals, Inc.

  17. [Design of longitudinal auto-tracking of the detector on X-ray in digital radiography].

    PubMed

    Yu, Xiaomin; Jiang, Tianhao; Liu, Zhihong; Zhao, Xu

    2018-04-01

    One algorithm is designed to implement longitudinal auto-tracking of the the detector on X-ray in the digital radiography system (DR) with manual collimator. In this study, when the longitudinal length of field of view (LFOV) on the detector is coincided with the longitudinal effective imaging size of the detector, the collimator half open angle ( Ψ ), the maximum centric distance ( e max ) between the center of X-ray field of view and the projection center of the focal spot, and the detector moving distance for auto-traking can be calculated automatically. When LFOV is smaller than the longitudinal effective imaging size of the detector by reducing Ψ , the e max can still be used to calculate the detector moving distance. Using this auto-tracking algorithm in DR with manual collimator, the tested results show that the X-ray projection is totally covered by the effective imaging area of the detector, although the center of the field of view is not aligned with the center of the effective imaging area of the detector. As a simple and low-cost design, the algorithm can be used for longitudinal auto-tracking of the detector on X-ray in the manual collimator DR.

  18. [DNA extraction from bones and teeth using AutoMate Express forensic DNA extraction system].

    PubMed

    Gao, Lin-Lin; Xu, Nian-Lai; Xie, Wei; Ding, Shao-Cheng; Wang, Dong-Jing; Ma, Li-Qin; Li, You-Ying

    2013-04-01

    To explore a new method in order to extract DNA from bones and teeth automatically. Samples of 33 bones and 15 teeth were acquired by freeze-mill method and manual method, respectively. DNA materials were extracted and quantified from the triturated samples by AutoMate Express forensic DNA extraction system. DNA extraction from bones and teeth were completed in 3 hours using the AutoMate Express forensic DNA extraction system. There was no statistical difference between the two methods in the DNA concentration of bones. Both bones and teeth got the good STR typing by freeze-mill method, and the DNA concentration of teeth was higher than those by manual method. AutoMate Express forensic DNA extraction system is a new method to extract DNA from bones and teeth, which can be applied in forensic practice.

  19. The Role of Cultural Context in Continuing Vocational Training: A Study on Auto Repairmen in Turkey

    ERIC Educational Resources Information Center

    Akbas, Oktay

    2011-01-01

    This study analysed how auto repairmen working in micro-enterprises undertake continuing vocational training in relation to cultural context. The study was conducted in Kirikkale, a city in central Anatolia in Turkey. To this end, the descriptive research technique of structured interview was used. Interviews with 33 auto repairmen were recorded…

  20. AutoQSAR: an automated machine learning tool for best-practice quantitative structure-activity relationship modeling.

    PubMed

    Dixon, Steven L; Duan, Jianxin; Smith, Ethan; Von Bargen, Christopher D; Sherman, Woody; Repasky, Matthew P

    2016-10-01

    We introduce AutoQSAR, an automated machine-learning application to build, validate and deploy quantitative structure-activity relationship (QSAR) models. The process of descriptor generation, feature selection and the creation of a large number of QSAR models has been automated into a single workflow within AutoQSAR. The models are built using a variety of machine-learning methods, and each model is scored using a novel approach. Effectiveness of the method is demonstrated through comparison with literature QSAR models using identical datasets for six end points: protein-ligand binding affinity, solubility, blood-brain barrier permeability, carcinogenicity, mutagenicity and bioaccumulation in fish. AutoQSAR demonstrates similar or better predictive performance as compared with published results for four of the six endpoints while requiring minimal human time and expertise.

  1. Optimal level of continuous positive airway pressure: auto-adjusting titration versus titration with a predictive equation.

    PubMed

    Choi, Ji Ho; Jun, Young Joon; Oh, Jeong In; Jung, Jong Yoon; Hwang, Gyu Ho; Kwon, Soon Young; Lee, Heung Man; Kim, Tae Hoon; Lee, Sang Hag; Lee, Seung Hoon

    2013-05-01

    The aims of the present study were twofold. We sought to compare two methods of titrating the level of continuous positive airway pressure (CPAP) - auto-adjusting titration and titration using a predictive equation - with full-night manual titration used as the benchmark. We also investigated the reliability of the two methods in patients with obstructive sleep apnea syndrome (OSAS). Twenty consecutive adult patients with OSAS who had successful, full-night manual and auto-adjusting CPAP titration participated in this study. The titration pressure level was calculated with a previously developed predictive equation based on body mass index and apnea-hypopnea index. The mean titration pressure levels obtained with the manual, auto-adjusting, and predictive equation methods were 9.0 +/- 3.6, 9.4 +/- 3.0, and 8.1 +/- 1.6 cm H2O,respectively. There was a significant difference in the concordance within the range of +/- 2 cm H2O (p = 0.019) between both the auto-adjusting titration and the titration using the predictive equation compared to the full-night manual titration. However, there was no significant difference in the concordance within the range of +/- 1 cm H2O (p > 0.999). When compared to full-night manual titration as the standard method, auto-adjusting titration appears to be more reliable than using a predictive equation for determining the optimal CPAP level in patients with OSAS.

  2. JADOPPT: java based AutoDock preparing and processing tool.

    PubMed

    García-Pérez, Carlos; Peláez, Rafael; Therón, Roberto; Luis López-Pérez, José

    2017-02-15

    AutoDock is a very popular software package for docking and virtual screening. However, currently it is hard work to visualize more than one result from the virtual screening at a time. To overcome this limitation we have designed JADOPPT, a tool for automatically preparing and processing multiple ligand-protein docked poses obtained from AutoDock. It allows the simultaneous visual assessment and comparison of multiple poses through clustering methods. Moreover, it permits the representation of reference ligands with known binding modes, binding site residues, highly scoring regions for the ligand, and the calculated binding energy of the best ranked results. JADOPPT, supplementary material (Case Studies 1 and 2) and video tutorials are available at http://visualanalytics.land/cgarcia/JADOPPT.html. carlosgarcia@usal.es or pelaez@usal.es. Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  3. Feasibility study of shared-ride auto transit. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kocur, G.; Zaelke, D.; Neumann, L.

    1977-09-01

    The report examines the feasibility of the implementation of shared-ride auto transit (SRAT), which is an innovative approach for increasing auto occupancy in rural and urban areas. The report focuses on operational concepts, potential usage, legal and regulatory issues, and institutional issues. Formulation of the SRAT concept was motivated by several concerns, such as: (1) energy conservation; (2) transit service to areas unable to economically justify conventional transit services, and to travel disadvantaged groups; (3) transit service replacement to achieve greater efficiency and to reduce transit deficits; (4) provision of inexpensive transit service; and (5) the increase of safety andmore » reliability of hitchhiking. Four case study sites (Boulder, Colorado; Boston, Massachusetts; Portland, Oregon; and Tidewater, Virginia), were used to identify the specific institutional issues likely to impact SRAT implementation for that site, and to identify the opportunities for designing, implementing and operating SRAT in a variety of institutional settings.« less

  4. SU-F-T-358: Is Auto-Planning Useful for Volumetric-Modulated Arc Therapy Planning in Rectal Cancer Radiotherapy?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, K; Chang, X; Wang, J

    Purpose: To evaluate whether Auto-Planning based volumetric-modulated radiotherapy (auto-VMAT) can reduce manual interaction time during treatment planning and improve plan quality for rectal cancer radiotherapy. Methods: Ten rectal cancer patients (stage II and III) after radical resection using Dixon surgery were enrolled. All patients were treated with VMAT technique. The manual VMAT plans (man-VMAT) were designed in the Pinnacle treatment planning system (Version 9.10) following the standard treatment planning procedure developed in our department. Clinical plans were manually designed by our experienced dosimetrists. Additionally, an auto-VMAT plan was created for each patient using Auto-Planning module. However, manual interaction was stillmore » applied to meet the clinical requirements. The treatment planning time and plan quality surrogated by the DVH parameters were compared between manual and automated plans. Results: The total planning time and manual interaction time were 50.38 and 4.47 min for the auto-VMAT and 36.81 and 16.94 min for the man-VMAT (t=60.14,−23.86; p=0.000, 0.000). In terms of plan quality, both plans meet the clinical requirements. The PTV homogeneity index (HI) and conformity index (CI) were 0.054 and 0.822 for the auto-VMAT and 0.059 and 0.815 for the man-VMAT (t=−1.72, 0.36;p=0.119,0.730).Compared to the man-VMAT, the auto-VMAT showed reduction of 11.9% and 0.7% in V40 and V50 of the bladder, respectively.The V30 and D mean were reduced by 14.0% and 5.1Gy in the left femur and 12.2% and 3.8Gy in the right femur. Conclusion: The Auto-Planning based VMAT plans not only shows similar or superior plan quality to the manual ones in the rectal cancer radiotherapy, but also improve the planning efficiency significantly. However, manual interactions are still required to achieve a clinically acceptable plan based on our experiences.« less

  5. AutoMap User’s Guide 2011

    DTIC Science & Technology

    2011-06-13

    important links. Dave likes milk and cookies but John likes cauliflower 107 The example sentence above contains nine concepts. Manually reviewing this...sentence reveals that milk and cookies are associated with Dave and cauliflower is associated with John. But using a direction of unidirectional and...a window size of 9 results in cauliflower also being associated with Dave. 18 JAN 10 GUI Section The AutoMap GUI is a graphic interface for

  6. Biochemical and Ultrastructural Changes in Sida cordifolia L. and Catharanthus roseus L. to Auto Pollution

    PubMed Central

    Verma, Vijeta; Chandra, Neelam

    2014-01-01

    Auto pollution is the by-product of our mechanized mobility, which adversely affects both plant and human life. However, plants growing in the urban locations provide a great respite to us from the brunt of auto pollution by absorbing the pollutants at their foliar surface. Foliar surface configuration and biochemical changes in plant species, namely, Sida cordifolia L. and Catharanthus roseus L. grown at roadside (polluted site 1, Talkatora; polluted site 2, Charbagh) in Lucknow city and in the garden of the university campus, which has been taken as reference site, were investigated. It was observed that air pollution caused by auto exhaust showed marked alterations in photosynthetic pigments (chlorophyll, carotenoid, and phaeophytin), and relative water content was reduced while antioxidative enzymes like catalase and peroxidase were found to be enhanced. The changes in the foliar configuration reveal marked alteration in epidermal traits, with decreased number of stomata, stomatal indices, and epidermal cells per unit area, while length and breadth of stomata and epidermal cells were found to be increased in leaves samples wich can be used as biomarkers of auto pollution. PMID:27355010

  7. Development of emission factors for motorcycles and shared auto-rickshaws using real-world driving cycle for a typical Indian city.

    PubMed

    Adak, Prasenjit; Sahu, Ravi; Elumalai, Suresh Pandian

    2016-02-15

    Vehicular emission is one of the most important contributors of urban air pollution. To quantify the impact of traffic on urban air quality, it is necessary to quantify vehicular emission. In many cities of India, such as Dhanbad, shared auto-rickshaw is the pre-dominant mode of transportation. Indian Driving Cycle (IDC) and Modified Indian Driving Cycle (MIDC) are used for emission testing of motorcycles, shared auto-rickshaws and passenger cars in India for regulatory purposes. IDC used for motorcycles and shared auto-rickshaws does not recognize the difference in two vehicle classes in terms of driving pattern. In real world, shared auto-rickshaws, behave differently than motorcycles. To quantify the impact of shared auto-rickshaws on urban air quality accurately, emission factors (EFs) are required to derive from real-world driving cycles (DCs). In heterogeneous traffic, vehicles of one class affect the behavior of vehicles of other classes. To estimate the emissions from different vehicle classes accurately, EFs for motorcycles and passenger cars are also required to be revised. In this study, real-world DCs were developed for motorcycles, shared auto-rickshaws and passenger cars in Dhanbad. Developed DCs were used to calculate EFs for respective classes. Shared auto-rickshaws were found to have the highest deviation from EFs derived using IDC. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Hemodynamic responses to external counterbalancing of auto-positive end-expiratory pressure in mechanically ventilated patients with chronic obstructive pulmonary disease.

    PubMed

    Baigorri, F; de Monte, A; Blanch, L; Fernández, R; Vallés, J; Mestre, J; Saura, P; Artigas, A

    1994-11-01

    To study the effect of positive end-expiratory pressure (PEEP) on right ventricular hemodynamics and ejection fraction in patients with chronic obstructive pulmonary disease and positive alveolar pressure throughout expiration by dynamic hyperinflation (auto-PEEP). Open, prospective, controlled trial. General intensive care unit of a community hospital. Ten patients sedated and paralyzed with an acute exacerbation of chronic obstructive pulmonary disease undergoing mechanical ventilation. Insertion of a pulmonary artery catheter modified with a rapid response thermistor and a radial arterial catheter. PEEP was then increased from 0 (PEEP 0) to auto-PEEP level (PEEP = auto-PEEP) and 5 cm H2O above that (PEEP = auto-PEEP +5). At each level of PEEP, airway pressures, flow and volume, hemodynamic variables (including right ventricular ejection fraction by thermodilution technique), and blood gas analyses were recorded. The mean auto-PEEP was 6.6 +/- 2.8 cm H2O and the total PEEP reached was 12.2 +/- 2.4 cm H2O. The degree of lung inflation induced by PEEP averaged 145 +/- 87 mL with PEEP = auto-PEEP and 495 +/- 133 mL with PEEP = auto-PEEP + 5. The PEEP = auto-PEEP caused a right ventricular end-diastolic pressure increase, but there was no other significant hemodynamic change. With PEEP = auto-PEEP + 5, there was a significant increase in intravascular pressures; this amount of PEEP reduced cardiac output (from 4.40 +/- 1.38 L/min at PEEP 0 to 4.13 +/- 1.48 L/min; p < .05). The cardiac output reduction induced by PEEP = auto-PEEP + 5 was > 10% in only five cases and this group of patients had significantly lower right ventricular volumes than the group with less cardiac output variation (right ventricular end-diastolic volume: 64 +/- 9 vs. 96 +/- 26 mL/m2; right ventricular end-systolic volume: 38 +/- 6 vs. 65 +/- 21 mL/m2; p < .05) without significant difference in the other variables that were measured. Neither right ventricular ejection fraction nor right ventricle

  9. Auto-Tutorial Instruction in Entomology: Principles of Entomology (Orders).

    ERIC Educational Resources Information Center

    Minnick, D. R.; Steele, K. L.

    Auto-tutorial instruction was compared to traditional lecture instruction in a university entomology course. In seven consecutive terms, undergraduate students enrolled in an introductory entomology course were divided into two groups: Group I received only lecture instruction on insect orders, while Group II was dismissed for three consecutive…

  10. Knowledge of allergies and performance in epinephrine auto-injector use: a controlled intervention in preschool teachers.

    PubMed

    Dumeier, Henriette Karoline; Richter, Luca Anne; Neininger, Martina Patrizia; Prenzel, Freerk; Kiess, Wieland; Bertsche, Astrid; Bertsche, Thilo

    2018-04-01

    Epinephrine auto-injectors are used for first aid in anaphylactic emergencies by non-healthcare professionals, e.g., (pre-)school teachers. We developed an education session for preschool teachers addressing allergies, anaphylactic emergencies, and administering auto-injectors. We assessed their attitudes and knowledge in allergies and anaphylactic emergency by a questionnaire and monitored their practical performance in administering auto-injectors before the education session, directly after, and 4-12 weeks after the session. From 75 teachers giving their consent to participate, 81% had children with allergies under their supervision and 3% had already administered medication from an available rescue kit. The knowledge of triggers of allergies increased from 9 to 55% directly and to 33% 4-12 weeks after the session (both p < 0.001, compared to baseline). Directly after the session, the number of teachers who felt well-prepared for an anaphylactic emergency rose from 11 to 88%, which decreased to 79% 4-12 weeks thereafter (each p < 0.001). The number of auto-injector administrations without any drug-related problems increased from 3 to 35% directly after the session and shrunk to 16% 4-12 weeks afterwards (both p < 0.025). A single education session substantially improved preschool teachers' attitudes and knowledge in allergies and anaphylactic emergencies. Additionally, their practical performance in auto-injector administration increased. What is Known: • Food allergies are increasing among children. • The knowledge about allergies and anaphylactic emergencies is poor. What is New: • The proportion of teachers who felt well-prepared for an anaphylactic emergency increased after a single education session. • The proportion of auto-injector administrations without any drug-related problems additionally increased due to an education session.

  11. Confirmatory factor analysis of the Autonomy over Tobacco Scale (AUTOS) in adults.

    PubMed

    Wellman, Robert J; DiFranza, Joseph R; O'Loughlin, Jennifer

    2015-11-01

    The Autonomy over Tobacco Scale (AUTOS), a 12-item self-administered questionnaire, was designed to measure autonomy in three correlated lower-order symptom domains: withdrawal, psychological dependence, and cue-induced craving. The factor structure of the AUTOS remains an open question; confirmatory analyses in adolescents supported the hierarchical structure, while exploratory analyses in adolescents and adults yield single-factor solutions. Here we seek to determine whether the hypothesized hierarchical structure is valid in adult smokers. The AUTOS was administered to two independent convenience samples of adult current smokers: a calibration sample recruited in the US for online studies, and a confirmation sample drawn from the prospective Nicotine Dependence in Teens study in Montreal. We tested competing hierarchical and single-factor models using the robust weighted least-squares (WLSMV) estimation method. A single-factor model that allowed correlated error variances between theoretically related items fit well in the calibration sample (n = 434), χ(2)SB(52) = 165.71; χ(2)/df = 3.19; SRMR = 0.03; CFI = 0.96; NNFI = 0.95; RMSEA = 0.07 (95% CI: 0.06, 0.08). Reliability of the single factor was high (ωB = 0.92) and construct validity was adequate. In the confirmation sample (n = 335), a similar model fit well:χ(2)SB(53) = 126.94; χ(2)/df = 2.44; SRMR = 0.04; CFI = 0.95; NNFI = 0.93; RMSEA = 0.07 (95% CI: 0.05, 0.08). Reliability of the single factor was again high (ωB = 0.92) and construct validity was adequate. The AUTOS is unidimensional in adult smokers. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. User productivity as a function of AutoCAD interface design.

    PubMed

    Mitta, D A; Flores, P L

    1995-12-01

    Increased operator productivity is a desired outcome of user-CAD interaction scenarios. Two objectives of this research were to (1) define a measure of operator productivity and (2) empirically investigate the potential effects of CAD interface design on operator productivity, where productivity is defined as the percentage of a drawing session correctly completed per unit time. Here, AutoCAD provides the CAD environment of interest. Productivity with respect to two AutoCAD interface designs (menu, template) and three task types (draw, dimension, display) was investigated. Analysis of user productivity data revealed significantly higher productivity under the menu interface condition than under the template interface condition. A significant effect of task type was also discovered, where user productivity under display tasks was higher than productivity under the draw and dimension tasks. Implications of these results are presented.

  13. Generating Code Review Documentation for Auto-Generated Mission-Critical Software

    NASA Technical Reports Server (NTRS)

    Denney, Ewen; Fischer, Bernd

    2009-01-01

    Model-based design and automated code generation are increasingly used at NASA to produce actual flight code, particularly in the Guidance, Navigation, and Control domain. However, since code generators are typically not qualified, there is no guarantee that their output is correct, and consequently auto-generated code still needs to be fully tested and certified. We have thus developed AUTOCERT, a generator-independent plug-in that supports the certification of auto-generated code. AUTOCERT takes a set of mission safety requirements, and formally verifies that the autogenerated code satisfies these requirements. It generates a natural language report that explains why and how the code complies with the specified requirements. The report is hyper-linked to both the program and the verification conditions and thus provides a high-level structured argument containing tracing information for use in code reviews.

  14. Is emotional dysregulation a risk indicator for auto-aggression behaviors in adolescents with oppositional defiant disorder?

    PubMed

    Muratori, Pietro; Pisano, Simone; Milone, Annarita; Masi, Gabriele

    2017-01-15

    The Child Behavior Checklist Dysregulation Profile (CBCL-DP), (high scores in Anxious/Depressed, Attention Problems, and Aggressive Behavior subscales), has been related to poor emotional and behavioral self-regulation in children and adolescents. Our aim is to evaluate if it may be associated with auto-aggression in youth with oppositional defiant disorder (ODD). Method In 72 consecutively referred youths with ODD, emotional dysregulation was assessed with the CBCL-DP, auto-aggression and physical aggression against other persons with the Modified Overt Aggression Scale. Regression analysis showed that greater higher CBCL-DP scores were associated to higher levels of auto-aggression, even when controlling for the levels of physical aggression against others and CBCL Total score. The small sample size, the cross-sectional design, and the lack of a control group limit the generalization of our findings. Referred ODD youths with higher scores of CBCL-DP are more likely to present auto-aggression, besides aggression against others. The CBCL could improve the screening and detection of these high-risk patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Design of an iterative auto-tuning algorithm for a fuzzy PID controller

    NASA Astrophysics Data System (ADS)

    Saeed, Bakhtiar I.; Mehrdadi, B.

    2012-05-01

    Since the first application of fuzzy logic in the field of control engineering, it has been extensively employed in controlling a wide range of applications. The human knowledge on controlling complex and non-linear processes can be incorporated into a controller in the form of linguistic terms. However, with the lack of analytical design study it is becoming more difficult to auto-tune controller parameters. Fuzzy logic controller has several parameters that can be adjusted, such as: membership functions, rule-base and scaling gains. Furthermore, it is not always easy to find the relation between the type of membership functions or rule-base and the controller performance. This study proposes a new systematic auto-tuning algorithm to fine tune fuzzy logic controller gains. A fuzzy PID controller is proposed and applied to several second order systems. The relationship between the closed-loop response and the controller parameters is analysed to devise an auto-tuning method. The results show that the proposed method is highly effective and produces zero overshoot with enhanced transient response. In addition, the robustness of the controller is investigated in the case of parameter changes and the results show a satisfactory performance.

  16. Neuropsychological correlates of cognitive, emotional-affective and auto-activation apathy in Alzheimer's disease.

    PubMed

    Perri, Roberta; Turchetta, Chiara Stella; Caruso, Giulia; Fadda, Lucia; Caltagirone, Carlo; Carlesimo, Augusto Giovanni

    2018-01-31

    Apathy symptoms include different dimensions: cognitive (C), emotional-affective (E-Aff) and auto-activation; they have been related to dysfunctions of the dorsolateral, orbito-basal prefrontal cortex and the subcortical frontal connections to the basal ganglia, respectively. In Alzheimer's disease (AD), an association has been found between apathy severity and both executive deficits and atrophy of the dorso-lateral prefrontal cortex; however, it is not clear whether these associations concern only the cognitive aspects of apathy. Furthermore, whether there is an association in AD between E-aff apathy and theory of mind (ToM),the cognitive functions subsumed by the orbito-basal prefrontal cortex, has not been investigated. Aim of the study was to investigate the relationship between C, E-Aff and auto-activation apathy and performance on tasks investigating executive and ToM cognitive functions in AD. For this purpose, 20 AD patients with apathy and 20 matched controls were submitted to an executive and ToM neuropsychological assessment. Apathy was assessed with a weekly diary (ApD) created specifically to assist caregivers in quantifying the C, E-Aff and auto-activation symptomatology of apathy. Correlational analyses showed that AD patients' scores on the Modified Card Sorting Test (MCST) and Emotion Attribution tasks were correlated with most ApD scores. However, regression analyses showed that C diary scores were predicted by MCST performance, E-Aff diary scores by performance on the E-Attribution task and ApD scores measuring auto-activation apathy were predicted by both the MCST and the Emotion Attribution scores. These results confirm the co-occurrence of apathy and executive-function deficits in AD and suggest a specific association between AD patients' executive deficits and the cognitive component of apathy. Furthermore, they document, for the first time, an association between poor performance on tests assessing ToM abilities and the emotional

  17. Accidental cut-throat injuries from the broken windshield of an auto rickshaw: Two unusual cases.

    PubMed

    Swain, Rajanikanta; Dhaka, Shivani; Sharma, Munish; Bakshi, Mantaran Singh; Murty, O P; Sikary, Asit Kumar

    2018-01-01

    Accidental cut-throat injuries are extremely rare and usually involve a sharp-edged weapon. In this paper, two cases of a cut-throat wound to two auto-rickshaw drivers are presented where the broken windshield of the auto-rickshaws was responsible for the wounds. In both the cases, fatal incised wounds were present over the neck, cutting the soft tissue along with the major vessels. The death occurred due to exsanguination caused by neck-vessel injury in one case and trachea along with neck-vessel injury in the second case. Although the wounds on the neck initially suggested homicide, they were found to have occurred accidentally as a result of a road traffic accident involving a head-on collision of auto rickshaws. The injuries were inflicted by the shattered glass of the windshield.

  18. Structural and optical properties of Ga auto-incorporated InAlN epilayers

    NASA Astrophysics Data System (ADS)

    Taylor, E.; Smith, M. D.; Sadler, T. C.; Lorenz, K.; Li, H. N.; Alves, E.; Parbrook, P. J.; Martin, R. W.

    2014-12-01

    InAlN epilayers deposited on thick GaN buffer layers grown by metalorganic chemical vapour deposition (MOCVD) revealed an auto-incorporation of Ga when analysed by wavelength dispersive x-ray (WDX) spectroscopy and Rutherford backscattering spectrometry (RBS). Samples were grown under similar conditions with the change in reactor flow rate resulting in varying Ga contents of 12-24%. The increase in flow rate from 8000 to 24 000 sccm suppressed the Ga auto-incorporation which suggests that the likely cause is from residual Ga left behind from previous growth runs. The luminescence properties of the resultant InAlGaN layers were investigated using cathodoluminescence (CL) measurements.

  19. Magnonic crystal as a delay line for low-noise auto-oscillators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bankowski, Elena; Meitzler, Thomas; Khymyn, Roman S., E-mail: khiminr@gmail.com

    2015-09-21

    It is demonstrated that a delay line based on a one-dimensional magnonic crystal used in a feedback loop of a microwave auto-oscillator can substantially reduce the phase noise figure and improve other vital performance characteristics of the auto-oscillator. The advantage is achieved due to the increase of the effective delay time in the magnonic crystal, compared to the case of an un-patterned yttrium iron garnet (YIG) film, and improvement of the power-handling characteristics due to the now possible increase of the YIG film thickness. The internal modes of a magnonic crystal caused by the periodic energy exchange between the incidentmore » and reflected spin waves play the dominant role in the described effect.« less

  20. Introduccion a la hidraulica de aguas subterraneas : un texto programado para auto-ensenanza

    USGS Publications Warehouse

    Bennett, Gordon D.

    1987-01-01

    Este ' texto programado esta diseflado para ayudarle a comprender la teoria de la hidniulica de aguas subterraneas por medio de la auto-enseflanza. La instrucci6n programada es un enfoque a una materia, un metodo de aprender;que no elimina el esfuerzo mental del proceso de aprendizaje. Algunas secciones de este programa necesitan solamente ser leidas; otras tendrian que ser elaboradas con lapiz y papel. Algunas preguntas pueden ser contestadas directamente; otras requieren calculos. A medida que se avanza en el texto, tendra que consultar frecuentemente textos o referencias sobre matematicas, mecanica de fluidos e hidrologia. En cada una de las ocho partes del texto, inicie el programa de instrucci6n leyendo la Secci6n 1. Elija una respuesta a la pregunta al final de la secci6n y dirijase a la nueva secci6n indicada al lado de la respuesta escogida. Si su respuesta fue correcta, pase a la secci6n que contiene materia nueva y otra pregunta, y proceda tal como en la Secci6n 1. Si su respuesta no fue correcta, dirijase a la secci6n que contiene explicaciones adicionales sobre el tema anterior y que le indica volver a la pregunta inicial e intentar de nuevo. En este caso, valdra Ia pena repasar el material de la secci6n anterior. Continue de esta man era en el programa hasta que llegue a Ia secci6n que indica el final de la parte. Observe que aunque las secciones estan en orden numerico en cada una de las ocho partes, por lo general, usted no procedeni en secuencia numerica (Secci6n 1 ala Secci6n 2, etc.) de principia a fin.

  1. Auto-Coding UML Statecharts for Flight Software

    NASA Technical Reports Server (NTRS)

    Benowitz, Edward G; Clark, Ken; Watney, Garth J.

    2006-01-01

    Statecharts have been used as a means to communicate behaviors in a precise manner between system engineers and software engineers. Hand-translating a statechart to code, as done on some previous space missions, introduces the possibility of errors in the transformation from chart to code. To improve auto-coding, we have developed a process that generates flight code from UML statecharts. Our process is being used for the flight software on the Space Interferometer Mission (SIM).

  2. Auto-flotation of heterocyst enables the efficient production of renewable energy in cyanobacteria

    PubMed Central

    Chen, Ming; Li, Jihong; Zhang, Lei; Chang, Sandra; Liu, Chen; Wang, Jianlong; Li, Shizhong

    2014-01-01

    Utilizing cyanobacteria as a bioenergy resource is difficult due to the cost and energy consuming harvests of microalgal biomass. In this study, an auto-floating system was developed by increasing the photobiological H2 production in the heterocysts of filamentous cyanobacteria. An amount of 1.0 μM of diuron, which inhibited O2 production in cyanobacteria, resulted in a high rate of H2 production in heterocysts. The auto-floating process recovered 91.71% ± 1.22 of the accumulated microalgal biomass from the liquid media. Quantification analysis revealed that 0.72–1.10 μmol H2 per mg dry weight microalgal biomass was necessary to create this auto-floating system. Further bio-conversion by using anaerobic digestion converted the harvested microalgal biomass into biogas. Through this novel coupled system of photobiological H2 production and anaerobic digestion, a high level of light energy conversion efficiency from solar energy to bioenergy was attained with the values of 3.79% ± 0.76. PMID:24499777

  3. Distributed Fair Auto Rate Medium Access Control for IEEE 802.11 Based WLANs

    NASA Astrophysics Data System (ADS)

    Zhu, Yanfeng; Niu, Zhisheng

    Much research has shown that a carefully designed auto rate medium access control can utilize the underlying physical multi-rate capability to exploit the time-variation of the channel. In this paper, we develop a simple analytical model to elucidate the rule that maximizes the throughput of RTS/CTS based multi-rate wireless local area networks. Based on the discovered rule, we propose two distributed fair auto rate medium access control schemes called FARM and FARM+ from the view-point of throughput fairness and time-share fairness, respectively. With the proposed schemes, after receiving a RTS frame, the receiver selectively returns the CTS frame to inform the transmitter the maximum feasible rate probed by the signal-to-noise ratio of the received RTS frame. The key feature of the proposed schemes is that they are capable of maintaining throughput/time-share fairness in asymmetric situation where the distribution of SNR varies with stations. Extensive simulation results show that the proposed schemes outperform the existing throughput/time-share fair auto rate schemes in time-varying channel conditions.

  4. Method of development of the program of forming of parametrical drawings of details in the AutoCAD software product

    NASA Astrophysics Data System (ADS)

    Alshakova, E. L.

    2017-01-01

    The program in the AutoLISP language allows automatically to form parametrical drawings during the work in the AutoCAD software product. Students study development of programs on AutoLISP language with the use of the methodical complex containing methodical instructions in which real examples of creation of images and drawings are realized. Methodical instructions contain reference information necessary for the performance of the offered tasks. The method of step-by-step development of the program is the basis for training in programming on AutoLISP language: the program draws elements of the drawing of a detail by means of definitely created function which values of arguments register in that sequence in which AutoCAD gives out inquiries when performing the corresponding command in the editor. The process of the program design is reduced to the process of step-by-step formation of functions and sequence of their calls. The author considers the development of the AutoLISP program for the creation of parametrical drawings of details, the defined design, the user enters the dimensions of elements of details. These programs generate variants of tasks of the graphic works performed in educational process of "Engineering graphics", "Engineering and computer graphics" disciplines. Individual tasks allow to develop at students skills of independent work in reading and creation of drawings, as well as 3D modeling.

  5. Schistosome Infection Intensity Is Inversely Related to Auto-Reactive Antibody Levels

    PubMed Central

    Mutapi, Francisca; Imai, Natsuko; Nausch, Norman; Bourke, Claire D.; Rujeni, Nadine; Mitchell, Kate M.; Midzi, Nicholas; Woolhouse, Mark E. J.; Maizels, Rick M.; Mduluza, Takafira

    2011-01-01

    In animal experimental models, parasitic helminth infections can protect the host from auto-immune diseases. We conducted a population-scale human study investigating the relationship between helminth parasitism and auto-reactive antibodies and the subsequent effect of anti-helminthic treatment on this relationship. Levels of antinuclear antibodies (ANA) and plasma IL-10 were measured by enzyme linked immunosorbent assay in 613 Zimbabweans (aged 2–86 years) naturally exposed to the blood fluke Schistosoma haematobium. ANA levels were related to schistosome infection intensity and systemic IL-10 levels. All participants were offered treatment with the anti-helminthic drug praziquantel and 102 treated schoolchildren (5–16 years) were followed up 6 months post-antihelminthic treatment. ANA levels were inversely associated with current infection intensity but were independent of host age, sex and HIV status. Furthermore, after allowing for the confounding effects of schistosome infection intensity, ANA levels were inversely associated with systemic levels of IL-10. ANA levels increased significantly 6 months after anti-helminthic treatment. Our study shows that ANA levels are attenuated in helminth-infected humans and that anti-helminthic treatment of helminth-infected people can significantly increase ANA levels. The implications of these findings are relevant for understanding both the aetiology of immune disorders mediated by auto-reactive antibodies and in predicting the long-term consequences of large-scale schistosomiasis control programs. PMID:21573157

  6. Brakes. Auto Mechanics Curriculum Guide. Module 6. Instructor's Guide.

    ERIC Educational Resources Information Center

    Allain, Robert

    This module is the sixth of nine modules in the competency-based Missouri Auto Mechanics Curriculum Guide. Eight units cover: introduction to automotive brake systems; disc and drum brake system components and how they operate; properties of brake fluid and procedures for bleeding the brake system; diagnosing and determining needed repairs on…

  7. Capturing the Sun: A Roadmap for Navigating Data-Access Challenges and Auto-Populating Solar Home Sales Listings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stukel, Laura; Hoen, Ben; Adomatis, Sandra

    Capturing the Sun: A Roadmap for Navigating Data-Access Challenges and Auto-Populating Solar Home Sales Listings supports a vision of solar photovoltaic (PV) advocates and real estate advocates evolving together to make information about solar homes more accessible to home buyers and sellers and to simplify the process when these homes are resold. The Roadmap is based on a concept in the real estate industry known as automatic population of fields. Auto-population (also called auto-pop in the industry) is the technology that allows data aggregated by an outside industry to be matched automatically with home sale listings in a multiple listingmore » service (MLS).« less

  8. Exploiting Auto-Collimation for Real-Time Onboard Monitoring of Space Optical Camera Geometric Parameters

    NASA Astrophysics Data System (ADS)

    Liu, W.; Wang, H.; Liu, D.; Miu, Y.

    2018-05-01

    Precise geometric parameters are essential to ensure the positioning accuracy for space optical cameras. However, state-of-the-art onorbit calibration method inevitably suffers from long update cycle and poor timeliness performance. To this end, in this paper we exploit the optical auto-collimation principle and propose a real-time onboard calibration scheme for monitoring key geometric parameters. Specifically, in the proposed scheme, auto-collimation devices are first designed by installing collimated light sources, area-array CCDs, and prisms inside the satellite payload system. Through utilizing those devices, the changes in the geometric parameters are elegantly converted into changes in the spot image positions. The variation of geometric parameters can be derived via extracting and processing the spot images. An experimental platform is then set up to verify the feasibility and analyze the precision index of the proposed scheme. The experiment results demonstrate that it is feasible to apply the optical auto-collimation principle for real-time onboard monitoring.

  9. Allosteric auto-inhibition and activation of the Nedd4 family E3 ligase Itch.

    PubMed

    Zhu, Kang; Shan, Zelin; Chen, Xing; Cai, Yuqun; Cui, Lei; Yao, Weiyi; Wang, Zhen; Shi, Pan; Tian, Changlin; Lou, Jizhong; Xie, Yunli; Wen, Wenyu

    2017-09-01

    The Nedd4 family E3 ligases are key regulators of cell growth and proliferation and are often misregulated in human cancers and other diseases. The ligase activities of Nedd4 E3s are tightly controlled via auto-inhibition. However, the molecular mechanism underlying Nedd4 E3 auto-inhibition and activation is poorly understood. Here, we show that the WW domains proceeding the catalytic HECT domain play an inhibitory role by binding directly to HECT in the Nedd4 E3 family member Itch. Our structural and biochemical analyses of Itch reveal that the WW2 domain and a following linker allosterically lock HECT in an inactive state inhibiting E2-E3 transthiolation. Binding of the Ndfip1 adaptor or JNK1-mediated phosphorylation relieves the auto-inhibition of Itch in a WW2-dependent manner. Aberrant activation of Itch leads to migration defects of cortical neurons during development. Our study provides a new mechanism governing the regulation of Itch. © 2017 The Authors.

  10. Directly auto-transplanted mesenchymal stem cells induce bone formation in a ceramic bone substitute in an ectopic sheep model.

    PubMed

    Boos, Anja M; Loew, Johanna S; Deschler, Gloria; Arkudas, Andreas; Bleiziffer, Oliver; Gulle, Heinz; Dragu, Adrian; Kneser, Ulrich; Horch, Raymund E; Beier, Justus P

    2011-06-01

    Bone tissue engineering approaches increasingly focus on the use of mesenchymal stem cells (MSC). In most animal transplantation models MSC are isolated and expanded before auto cell transplantation which might be critical for clinical application in the future. Hence this study compares the potential of directly auto-transplanted versus in vitro expanded MSC with or without bone morphogenetic protein-2 (BMP-2) to induce bone formation in a large volume ceramic bone substitute in the sheep model. MSC were isolated from bone marrow aspirates and directly auto-transplanted or expanded in vitro and characterized using fluorescence activated cell sorting (FACS) and RT-PCR analysis before subcutaneous implantation in combination with BMP-2 and β-tricalcium phosphate/hydroxyapatite (β-TCP/HA) granules. Constructs were explanted after 1 to 12 weeks followed by histological and RT-PCR evaluation. Sheep MSC were CD29(+), CD44(+) and CD166(+) after selection by Ficoll gradient centrifugation, while directly auto-transplanted MSC-populations expressed CD29 and CD166 at lower levels. Both, directly auto-transplanted and expanded MSC, were constantly proliferating and had a decreasing apoptosis over time in vivo. Directly auto-transplanted MSC led to de novo bone formation in a heterotopic sheep model using a β-TCP/HA matrix comparable to the application of 60 μg/ml BMP-2 only or implantation of expanded MSC. Bone matrix proteins were up-regulated in constructs following direct auto-transplantation and in expanded MSC as well as in BMP-2 constructs. Up-regulation was detected using immunohistology methods and RT-PCR. Dense vascularization was demonstrated by CD31 immunohistology staining in all three groups. Ectopic bone could be generated using directly auto-transplanted or expanded MSC with β-TCP/HA granules alone. Hence BMP-2 stimulation might become dispensable in the future, thus providing an attractive, clinically feasible approach to bone tissue engineering. © 2011

  11. Directly auto-transplanted mesenchymal stem cells induce bone formation in a ceramic bone substitute in an ectopic sheep model

    PubMed Central

    Boos, Anja M; Loew, Johanna S; Deschler, Gloria; Arkudas, Andreas; Bleiziffer, Oliver; Gulle, Heinz; Dragu, Adrian; Kneser, Ulrich; Horch, Raymund E; Beier, Justus P

    2011-01-01

    Abstract Bone tissue engineering approaches increasingly focus on the use of mesenchymal stem cells (MSC). In most animal transplantation models MSC are isolated and expanded before auto cell transplantation which might be critical for clinical application in the future. Hence this study compares the potential of directly auto-transplanted versus in vitro expanded MSC with or without bone morphogenetic protein-2 (BMP-2) to induce bone formation in a large volume ceramic bone substitute in the sheep model. MSC were isolated from bone marrow aspirates and directly auto-transplanted or expanded in vitro and characterized using fluorescence activated cell sorting (FACS) and RT-PCR analysis before subcutaneous implantation in combination with BMP-2 and β-tricalcium phosphate/hydroxyapatite (β-TCP/HA) granules. Constructs were explanted after 1 to 12 weeks followed by histological and RT-PCR evaluation. Sheep MSC were CD29+, CD44+ and CD166+ after selection by Ficoll gradient centrifugation, while directly auto-transplanted MSC-populations expressed CD29 and CD166 at lower levels. Both, directly auto-transplanted and expanded MSC, were constantly proliferating and had a decreasing apoptosis over time in vivo. Directly auto-transplanted MSC led to de novo bone formation in a heterotopic sheep model using a β-TCP/HA matrix comparable to the application of 60 μg/ml BMP-2 only or implantation of expanded MSC. Bone matrix proteins were up-regulated in constructs following direct auto-transplantation and in expanded MSC as well as in BMP-2 constructs. Up-regulation was detected using immunohistology methods and RT-PCR. Dense vascularization was demonstrated by CD31 immunohistology staining in all three groups. Ectopic bone could be generated using directly auto-transplanted or expanded MSC with β-TCP/HA granules alone. Hence BMP-2 stimulation might become dispensable in the future, thus providing an attractive, clinically feasible approach to bone tissue engineering. PMID

  12. Basic Evaluation of the Newly Developed "Lias Auto P-FDP" Assay and the Influence of Plasmin-α2 Plasmin Inhibitor Complex Values on Discrepancy in the Comparison with "Lias Auto D-Dimer Neo" Assay.

    PubMed

    Kumano, Osamu; Ieko, Masahiro; Komiyama, Yutaka; Naito, Sumiyoshi; Yoshida, Mika; Takahashi, Nobuhiko; Ohmura, Kazumasa; Hayasaki, Junki; Hayakawa, Mineji

    2018-04-01

    Laboratory determination of fibrin/fibrinogen degradation products (FDP) levels, along with that of the D-dimer, is important for assessing the fibrinolytic situation. Recently, we developed a new FDP reagent "Lias Auto P-FDP", which can detect various FDP fragments. The purpose of this study was to evaluate the basic performance of the newly developed Lias Auto P-FDP and compare it with Lias Auto D-Dimer Neo assay. The within-run precision of Lias Auto P-FDP and Lias Auto D-Dimer was determined 20 times in low and high value controls. The between-day precision was evaluated five times a day for five days. The linearity study was performed by diluting high value samples for 2 - 10-fold and 2 - 8-fold. The comparative study was performed using 172 patient samples with elevated FDP values. For the discrepancy analysis, the samples were divided into three groups by the discrepancy percentage between the FDP and D-dimer values. The groups were defined as follows: lower discrepancy group, less than -20%; no discrepancy group, -20% to 20%; upper discrepancy group, more than 20%. The coefficient of variation % (CV%) in within-run and between-day precision were within 3.8% for both FDP and the D-dimer. The correlation coefficients were more than 0.999 and the linearity was high. In the comparative study, the values of FDP were higher than that of the D-dimer in all samples. The median FDP and D-dimer values of lower discrepancy, no discrepancy, and upper discrepancy groups were 11.8, 20.3, and 51.4, and 8.0, 11.3, and 13.1, respectively. FDP showed an increasing tendency but D-Dimer showed constant values. Thus, the possible cause of discrepancy between FDP and D-dimer values were the elevated FDP values. In addition, the values of plasmin-α2 plasmin inhibitor complex (PIC) in the upper discrepancy group were higher than that of the lower and no discrepancy groups, indicating progression of fibrinolysis. In this study, we evaluated the newly developed Lias Auto P

  13. Repertoire of human natural anti-glycan immunoglobulins. Do we have auto-antibodies?

    PubMed

    Bovin, Nicolai; Obukhova, Polina; Shilova, Nadezhda; Rapoport, Evgenia; Popova, Inna; Navakouski, Maksim; Unverzagt, Carlo; Vuskovic, Marko; Huflejt, Margaret

    2012-09-01

    Profiling of donor's antibodies using glycan arrays demonstrated presence of antibodies capable of binding to >100 mammalian glycans or their fragments. For example, relatively high binding to Galα1-4Galβ1-4GlcNAc (P(1)), Galα1-4Galβ1-4Glc (P(k)), Galβ1-3GlcNAc (Le(c)), 4-O-SuGalβ1-4GlcNAc, and GalNAcα1-3GalNAc (Fs) was found in all tested individuals. Affinity isolation using hapten-specific chromatography in combination with epitope mapping revealed their glycotopes. Notably, a significant part of the antibodies was capable of recognizing a fragment of larger glycans, for example, -Galβ1-4Glc of glycolipids, or Fucα1-3GlcNAc motif of Le(X)/Le(Y) antigens. Their epitope specificity did not vary between different healthy individuals. Nominally, all the mentioned immunoglobulins could be classified as auto-antibodies. In this work we re-evaluated results published earlier and analyzed new data to address the question why autologous antibodies found in healthy individuals do not cause severe auto-immune reactions. In all cases the presumably "auto" antibodies were found to bind short fragments "subtracted" from larger glycans whereas recognition of the same fragment in the context of the whole natural chain was completely abolished. Thus, in spite of numerous formally positive signals observed on the printed glycan array, we are yet unable to identify in blood serum of healthy individuals true auto-antibodies capable of binding carbohydrate chains in their naturally occurring form. The identified natural anti-glycan antibodies were found to be specific, high-titer and population conservative immunoglobulins - all of this suggesting as yet unknown biological role(s) of the studied proteins. This article is part of a Special Issue entitled Glycoproteomics. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. [Auto-suture stapler EEA in surgery of the colon and rectum [author's transl)].

    PubMed

    Thiede, A; Troidl, H; Poser, H; Jostarndt, L; Hamelmann, H

    1980-01-01

    The increasing use of auto-suture staplers for gastrointestinal anastomoses makes it necessary to test the value of this new method of suturing. In a "pilot study" the practicability, the tightness and permeability of the anastomosis and complications were tested and analysed in a total of 30 colon and rectal anastomoses using the EEA-suture gun. The results of 14 colon resections and 16 low anterior resections justify the further use of the EEA auto-suture apparatus and raise the question of a prospective controlled random study in which manual and mechanical machine sutured anastomoses are compared.

  15. PERSPECTIVE VIEW OF THE C. 1925 AUTO SALES/GARAGE STRUCTURE LOCATED ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PERSPECTIVE VIEW OF THE C. 1925 AUTO SALES/GARAGE STRUCTURE LOCATED AT 205-209 SECOND STREET NORTHWEST. - Corvallis Downtown Historic District, Bounded by First & Sixth Streets, Van Buren & Western Avenues, Corvallis, Benton County, OR

  16. Auto-Gopher: A Wire-Line Rotary-Hammer Ultrasonic Drill

    NASA Technical Reports Server (NTRS)

    Badescu, Mircea; Sherrit, Stewart; Bao, Xiaogi; Bar-Cohen, Yoseph; Chen, Beck

    2011-01-01

    Developing technologies that would enable NASA to sample rock, soil, and ice by coring, drilling or abrading at a significant depth is of great importance for a large number of in-situ exploration missions as well as for earth applications. Proven techniques to sample Mars subsurface will be critical for future NASA astrobiology missions that will search for records of past and present life on the planet, as well as, the search for water and other resources. A deep corer, called Auto-Gopher, is currently being developed as a joint effort of the JPL's NDEAA laboratory and Honeybee Robotics Corp. The Auto-Gopher is a wire-line rotary-hammer drill that combines rock breaking by hammering using an ultrasonic actuator and cuttings removal by rotating a fluted bit. The hammering mechanism is based on the Ultrasonic/Sonic Drill/Corer (USDC) that has been developed as an adaptable tool for many of drilling and coring applications. The USDC uses an intermediate free-flying mass to transform the high frequency vibrations of the horn tip into a sonic hammering of a drill bit. The USDC concept was used in a previous task to develop an Ultrasonic/Sonic Ice Gopher. The lessons learned from testing the ice gopher were implemented into the design of the Auto-Gopher by inducing a rotary motion onto the fluted coring bit. A wire-line version of such a system would allow penetration of significant depth without a large increase in mass. A laboratory version of the corer was developed in the NDEAA lab to determine the design and drive parameters of the integrated system. The design configuration lab version of the design and fabrication and preliminary testing results are presented in this paper

  17. A method for modeling co-occurrence propensity of clinical codes with application to ICD-10-PCS auto-coding.

    PubMed

    Subotin, Michael; Davis, Anthony R

    2016-09-01

    Natural language processing methods for medical auto-coding, or automatic generation of medical billing codes from electronic health records, generally assign each code independently of the others. They may thus assign codes for closely related procedures or diagnoses to the same document, even when they do not tend to occur together in practice, simply because the right choice can be difficult to infer from the clinical narrative. We propose a method that injects awareness of the propensities for code co-occurrence into this process. First, a model is trained to estimate the conditional probability that one code is assigned by a human coder, given than another code is known to have been assigned to the same document. Then, at runtime, an iterative algorithm is used to apply this model to the output of an existing statistical auto-coder to modify the confidence scores of the codes. We tested this method in combination with a primary auto-coder for International Statistical Classification of Diseases-10 procedure codes, achieving a 12% relative improvement in F-score over the primary auto-coder baseline. The proposed method can be used, with appropriate features, in combination with any auto-coder that generates codes with different levels of confidence. The promising results obtained for International Statistical Classification of Diseases-10 procedure codes suggest that the proposed method may have wider applications in auto-coding. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Technological Change in the Auto Industry. CAW Technology Project.

    ERIC Educational Resources Information Center

    Robertson, David; Wareham, Jeff

    Today the auto industry is going through the most radical restructuring it has experienced since its birth. Included in this upheaval is a dramatic reorganization of the workplace, and technology has been both a catalyst and a central part of such change. The issues involved touch every facet of workplace life: job classifications and demarcation…

  19. High density growth of T7 expression strains with auto-induction option

    DOEpatents

    Studier, F. William

    2010-07-20

    A bacterial growth medium for promoting auto-induction of transcription of cloned DNA in cultures of bacterial cells grown batchwise is disclosed. The transcription is under the control of a lac repressor. Also disclosed is a bacterial growth medium for improving the production of a selenomethionine-containing protein or polypeptide in a bacterial cell, the protein or polypeptide being produced by recombinant DNA techniques from a lac or T7lac promoter, the bacterial cell encoding a vitamin B12-dependent homocysteine methylase. Finally, disclosed is a bacterial growth medium for suppressing auto-induction of expression in cultures of bacterial cells grown batchwise, said transcription being under the control of lac repressor.

  20. Pulse-excited, auto-zeroing multiple channel data transmission system

    NASA Astrophysics Data System (ADS)

    Fasching, G. E.

    1985-02-01

    A multiple channel data transmission system is provided in which signals from a plurality of pulse operated transducers and a corresponding plurality of pulse operated signal processor channels are multiplexed for single channel FM transmission to a receiving station. The transducers and corresponding channel amplifiers are powered by pulsing the dc battery power to these devices to conserve energy and battery size for long-term data transmission from remote or inaccessible locations. Auto zeroing of the signal channel amplifiers to compensate for drift associated with temperature changes, battery decay, component aging, etc., in each channel is accomplished by means of a unique auto zero feature which between signal pulses holds a zero correction voltage on an integrating capacitor coupled to the corresponding channel amplifier output. Pseudo-continuous outputs for each channel are achieved by pulsed sample-and-hold circuits which are updated at the pulsed operation rate. The sample-and-hold outputs are multiplexed into an FM/FM transmitter for transmission to an FM receiver station for demultiplexing and storage in separate channel recorders.

  1. Pulse-excited, auto-zeroing multiple channel data transmission system

    DOEpatents

    Fasching, G.E.

    1985-02-22

    A multiple channel data transmission system is provided in which signals from a plurality of pulse operated transducers and a corresponding plurality of pulse operated signal processor channels are multiplexed for single channel FM transmission to a receiving station. The transducers and corresponding channel amplifiers are powered by pulsing the dc battery power to these devices to conserve energy and battery size for long-term data transmission from remote or inaccessible locations. Auto zeroing of the signal channel amplifiers to compensate for drift associated with temperature changes, battery decay, component aging, etc., in each channel is accomplished by means of a unique auto zero feature which between signal pulses holds a zero correction voltage on an integrating capacitor coupled to the corresponding channel amplifier output. Pseudo-continuous outputs for each channel are achieved by pulsed sample-and-hold circuits which are updated at the pulsed operation rate. The sample-and-hold outputs are multiplexed into an FM/FM transmitter for transmission to an FM receiver station for demultiplexing and storage in separate channel recorders.

  2. Pulse-excited, auto-zeroing multiple channel data transmission system

    DOEpatents

    Fasching, George E.

    1987-01-01

    A multiple channel data transmission system is provided in which signals from a plurality of pulse operated transducers and a corresponding plurality of pulse operated signal processor channels are multiplexed for single channel FM transmission to a receiving station. The transducers and corresponding channel amplifiers are powered by pulsing the dc battery power to these devices to conserve energy and battery size for long-term data transmission from remote or inaccessible locations. Auto zeroing of the signal channel amplifiers to compensate for drift associated with temperature changes, battery decay, component aging, etc., in each channel is accomplished by means of a unique auto zero feature which between signal pulses holds a zero correction voltage on an integrating capacitor coupled to the corresponding channel amplifier output. Pseudo-continuous outputs for each channel are achieved by pulsed sample-and-hold circuits which are updated at the pulsed operation rate. The sample-and-hold outputs are multiplexed into an FM/FM transmitter for transmission to an FM receiver station for demultiplexing and storage in separate channel recorders.

  3. Monthly streamflow forecasting with auto-regressive integrated moving average

    NASA Astrophysics Data System (ADS)

    Nasir, Najah; Samsudin, Ruhaidah; Shabri, Ani

    2017-09-01

    Forecasting of streamflow is one of the many ways that can contribute to better decision making for water resource management. The auto-regressive integrated moving average (ARIMA) model was selected in this research for monthly streamflow forecasting with enhancement made by pre-processing the data using singular spectrum analysis (SSA). This study also proposed an extension of the SSA technique to include a step where clustering was performed on the eigenvector pairs before reconstruction of the time series. The monthly streamflow data of Sungai Muda at Jeniang, Sungai Muda at Jambatan Syed Omar and Sungai Ketil at Kuala Pegang was gathered from the Department of Irrigation and Drainage Malaysia. A ratio of 9:1 was used to divide the data into training and testing sets. The ARIMA, SSA-ARIMA and Clustered SSA-ARIMA models were all developed in R software. Results from the proposed model are then compared to a conventional auto-regressive integrated moving average model using the root-mean-square error and mean absolute error values. It was found that the proposed model can outperform the conventional model.

  4. Auto-ignition of lubricating oil working at high pressures in a compressor for an air conditioner.

    PubMed

    Kim, Chul Jin; Choi, Hyo Hyun; Sohn, Chae Hoon

    2011-01-15

    Auto-ignition of lubricating oil working in a compressor for an air conditioner is studied experimentally. The adopted lubricating oil is an unknown mixture with multi-components and known to have flash point temperature of 170 °C. First, its auto-ignition temperature is measured 365 °C at atmospheric pressure. The lubricating oil works under high-pressure condition up to 30 atm and it is heated and cooled down repeatedly. Accordingly, auto-ignition temperatures or flammable limits of lubricating oil are required at high pressures with respect to fire safety. Because there is not a standard test method for the purpose, a new ignition-test method is proposed in this study and thereby, auto-ignition temperatures are measured over the pressure range below 30 atm. The measured temperatures range from 215 °C to 255 °C and they strongly depend on pressure of gas mixture consisting of oil vapor, nitrogen, and oxygen. They are close to flash point temperature and the lubricating oil can be hazardous when it works for high-pressure operating condition and abundant air flows into a compressor. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. Early relapse after single auto-SCT for multiple myeloma is a major predictor of survival in the era of novel agents.

    PubMed

    Jimenez-Zepeda, V H; Reece, D E; Trudel, S; Chen, C; Tiedemann, R; Kukreti, V

    2015-02-01

    The role of auto-SCT in the treatment of multiple myeloma (MM) in the era of novel agents continues to evolve. It is now clear that the depth of response and clinical outcomes have significantly improved as a result of the combination of these strategies. However, not all patients with MM who undergo auto-SCT are able to sustain a meaningful response and 20% of patients relapse shortly after auto-SCT. In this study, we aimed to assess the impact of early relapse (ER) after auto-SCT on OS for MM patients undergoing single auto-SCT who had received novel agent-based induction regimens. All consecutive patients with MM undergoing single auto-SCT from January 2002 to September 2012 who had novel induction therapy were evaluated. A total of 184 patients were identified. The median OS and PFS for the group of transplanted patients were 93 and 25.4 months, respectively. Median time to relapse was 17.2 months with 40% having relapsed at the time of analysis. ER (<12 months post auto-SCT) was seen in 27 (36%) out of 75 patients who had relapsed, and median OS was significantly shorter than in those with non-ER. Multivariate analysis showed ER as the major independent prognostic factor for OS. On the basis of these findings, we conclude that not only attainment of a good response, but sustainability of it, appears to be a major prognostic variable in MM in the era of novel therapy. Patients with ER post auto-SCT should biologically be characterized in prospective studies to better understand the mechanisms of resistance associated with this particular entity.

  6. Certifying Auto-Generated Flight Code

    NASA Technical Reports Server (NTRS)

    Denney, Ewen

    2008-01-01

    Model-based design and automated code generation are being used increasingly at NASA. Many NASA projects now use MathWorks Simulink and Real-Time Workshop for at least some of their modeling and code development. However, there are substantial obstacles to more widespread adoption of code generators in safety-critical domains. Since code generators are typically not qualified, there is no guarantee that their output is correct, and consequently the generated code still needs to be fully tested and certified. Moreover, the regeneration of code can require complete recertification, which offsets many of the advantages of using a generator. Indeed, manual review of autocode can be more challenging than for hand-written code. Since the direct V&V of code generators is too laborious and complicated due to their complex (and often proprietary) nature, we have developed a generator plug-in to support the certification of the auto-generated code. Specifically, the AutoCert tool supports certification by formally verifying that the generated code is free of different safety violations, by constructing an independently verifiable certificate, and by explaining its analysis in a textual form suitable for code reviews. The generated documentation also contains substantial tracing information, allowing users to trace between model, code, documentation, and V&V artifacts. This enables missions to obtain assurance about the safety and reliability of the code without excessive manual V&V effort and, as a consequence, eases the acceptance of code generators in safety-critical contexts. The generation of explicit certificates and textual reports is particularly well-suited to supporting independent V&V. The primary contribution of this approach is the combination of human-friendly documentation with formal analysis. The key technical idea is to exploit the idiomatic nature of auto-generated code in order to automatically infer logical annotations. The annotation inference algorithm

  7. Evaluating the Auto-MODS Assay, a Novel Tool for Tuberculosis Diagnosis for Use in Resource-Limited Settings

    PubMed Central

    Wang, Linwei; Mohammad, Sohaib H.; Li, Qiaozhi; Rienthong, Somsak; Rienthong, Dhanida; Nedsuwan, Supalert; Mahasirimongkol, Surakameth; Yasui, Yutaka

    2014-01-01

    There is an urgent need for simple, rapid, and affordable diagnostic tests for tuberculosis (TB) to combat the great burden of the disease in developing countries. The microscopic observation drug susceptibility assay (MODS) is a promising tool to fill this need, but it is not widely used due to concerns regarding its biosafety and efficiency. This study evaluated the automated MODS (Auto-MODS), which operates on principles similar to those of MODS but with several key modifications, making it an appealing alternative to MODS in resource-limited settings. In the operational setting of Chiang Rai, Thailand, we compared the performance of Auto-MODS with the gold standard liquid culture method in Thailand, mycobacterial growth indicator tube (MGIT) 960 plus the SD Bioline TB Ag MPT64 test, in terms of accuracy and efficiency in differentiating TB and non-TB samples as well as distinguishing TB and multidrug-resistant (MDR) TB samples. Sputum samples from clinically diagnosed TB and non-TB subjects across 17 hospitals in Chiang Rai were consecutively collected from May 2011 to September 2012. A total of 360 samples were available for evaluation, of which 221 (61.4%) were positive and 139 (38.6%) were negative for mycobacterial cultures according to MGIT 960. Of the 221 true-positive samples, Auto-MODS identified 212 as positive and 9 as negative (sensitivity, 95.9%; 95% confidence interval [CI], 92.4% to 98.1%). Of the 139 true-negative samples, Auto-MODS identified 135 as negative and 4 as positive (specificity, 97.1%; 95% CI, 92.8% to 99.2%). The median time to culture positivity was 10 days, with an interquartile range of 8 to 13 days for Auto-MODS. Auto-MODS is an effective and cost-sensitive alternative diagnostic tool for TB diagnosis in resource-limited settings. PMID:25378569

  8. How far from correct is the use of adrenaline auto-injectors? A survey in Italian patients.

    PubMed

    Ridolo, Erminia; Montagni, Marcello; Bonzano, Laura; Savi, Eleonora; Peveri, Silvia; Costantino, Maria Teresa; Crivellaro, Mariangiola; Manzotti, Giuseppina; Lombardi, Carlo; Caminati, Marco; Incorvaia, Cristoforo; Senna, Gianenrico

    2015-12-01

    Self-administered adrenaline through an auto-injector is the main out-of-hospital treatment for anaphylaxis, and patients should be trained to promptly and correctly use the device. The aim of the study was to verify the proper use of the device and the correct drug administration, and to identify possible misuse by patients. In seven Italian Allergy clinics, patients who were previously provided with self-injectable adrenaline were recruited at the follow-up visit required for the renewal of their prescription. All patients completed a questionnaire covering details of their allergic reactions, and knowledge of the device. The correct use was verified by the physician using a trainer with a four-step examination. 242 patients were included; 46 patients (18 %) did not always carry the auto-injector, and 35 patients (14 %) reported situations in which they were doubtful about whether to use adrenaline. Only 39 % of patients properly managed the device, while some patients (6 %) failed in all four steps. The majority of patients considered it appropriate to use adrenaline at the onset of respiratory symptoms (56 %). The factor most closely related to proper use of the device was the education of the patient (p = 0.03), while age and the time from first prescription did not affect the ability to properly use the auto-injector. Even though accurate training is conducted, many patients are still unable to properly use the adrenaline auto-injector in case of anaphylaxis. Allergists should review the instructions provided to the patients every time a renewal of the auto-injector is prescribed.

  9. SEMICONDUCTOR INTEGRATED CIRCUITS: An asymmetric MOSFET-C band-pass filter with on-chip charge pump auto-tuning

    NASA Astrophysics Data System (ADS)

    Fangxiong, Chen; Min, Lin; Heping, Ma; Hailong, Jia; Yin, Shi; Forster, Dai

    2009-08-01

    An asymmetric MOSFET-C band-pass filter (BPF) with on chip charge pump auto-tuning is presented. It is implemented in UMC (United Manufacturing Corporation) 0.18 μm CMOS process technology. The filter system with auto-tuning uses a master-slave technique for continuous tuning in which the charge pump outputs 2.663 V, much higher than the power supply voltage, to improve the linearity of the filter. The main filter with third order low-pass and second order high-pass properties is an asymmetric band-pass filter with bandwidth of 2.730-5.340 MHz. The in-band third order harmonic input intercept point (IIP3) is 16.621 dBm, with 50 Ω as the source impedance. The input referred noise is about 47.455 μVrms. The main filter dissipates 3.528 mW while the auto-tuning system dissipates 2.412 mW from a 1.8 V power supply. The filter with the auto-tuning system occupies 0.592 mm2 and it can be utilized in GPS (global positioning system) and Bluetooth systems.

  10. Auto immune hemolytic anemia in a child precipitated by chicken pox.

    PubMed

    Billoo, Samina Shamim; Jamalvi, Syed Waseem

    2008-05-01

    Auto Immune Hemolytic Anemia (AIHA) is a rare entity in children. We report a case of an adolescent girl with AIHA, which was precipitated by chicken pox. Clinical course over 3 years, till remission is described.

  11. As the Auto Industry Shrinks, a Community College Retools

    ERIC Educational Resources Information Center

    Fischer, Karin

    2009-01-01

    In 1954, Chrysler introduced its "newest, smoothest" ride, the Dodge Royal sedan, which rolled off the assembly line with a glossy two-tone paint job and state-of-the-art V-8 engine. That same year, just northeast of Detroit, Macomb Community College opened its doors, with a mission to prepare the vehicle designers, auto-parts makers,…

  12. Careers in Auto Racing: Work in the Fast Lane

    ERIC Educational Resources Information Center

    Lawhorn, William

    2009-01-01

    Long before most people had seen an automobile, thrill-seekers across the globe were driving cars competitively. The speed of racecars has accelerated steadily, as has the popularity of the sport. In public opinion polls of sports popularity, in fact, auto racing consistently finishes near the top. Racecar drivers may be the star of their event,…

  13. [Prevention of intrauterine adhesion with auto-crosslinked hyaluronic acid gel: a prospective, randomized, controlled clinical study].

    PubMed

    Xiao, Songshu; Wan, Yajun; Zou, Fangjun; Ye, Mingzhu; Deng, Henan; Ma, Jiezhi; Wei, Yingying; Tan, Chen; Xue, Min

    2015-01-01

    To evaluate the efficacy and safety of auto-crosslinked hyaluronic acid (HA) gel for preventing intrauterine adhesion (IUA) after hysteroscopic adhesiolysis. A prospective, randomized, double blinded and controlled clinical trial (level I) was performed. According to American Fertility Society (AFS) scoring system, 120 patients (treatment group: 60 cases, control group: 60 cases) with moderate to severe IUA were enrolled. Upon completion of adhesiolysis, a Foley balloon catheter was first introduced into the uterine cavity and then 3 ml of auto-crosslinked HA gel for patients in the treatment group; patients in the control group, however, only received Foley balloon catheter. Second-look hysteroscopic examination was performed to all patients at 3 months postoperatively for evaluation of IUA. Primary endpoint was the reduction rate of IUA at 3 months after surgery. The secondary endpoints include total AFS score, score of each individual AFS category. At 3 months after surgery, auto-crosslinked HA gel resulted in significantly higher effective rate for reduction of adhesion, the effective rate were 76% (42/55) and 48% (27/56) respectively (P = 0.000 9); the total AFS score of treatment group was 2.1 ± 1.1, and significantly lower than that of control group (3.7 ± 2.5, P = 0.000 8). Application of auto-crosslinked HA gel after surgery significantly enhanced the improvement for each individual patient with regard to their adhesive type and menstrual pattern (P = 0.037 8, P = 0.000 4). The treatment group had significantly lower proportion of patients with moderate to severe adhesive stages than that of control group [13% (7/55) versus 38% (21/56), P = 0.000 6]. No adverse events and complications were observed. Auto-crosslinked HA gel coule be able to reduce IUA, decrease adhesion severity, and improve menopause postoperatively. This absorbable auto-crosslinked HA gel is proposed as a barrier for preventing IUA after intrauterine procedures.

  14. 14. INSPECTION PARTY IN AUTO DRIVEN THROUGH MILE ROCK TUNNEL, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. INSPECTION PARTY IN AUTO DRIVEN THROUGH MILE ROCK TUNNEL, AUG. 26, 1915. Department of Public Works, Map and Plan Room, photo #2545. - Mile Rock Tunnel, Under Forty-eighth Avenue from Cabrillo Street to San Francisco Bay at Point Lobos, San Francisco, San Francisco County, CA

  15. A novel method for intelligent fault diagnosis of rolling bearings using ensemble deep auto-encoders

    NASA Astrophysics Data System (ADS)

    Shao, Haidong; Jiang, Hongkai; Lin, Ying; Li, Xingqiu

    2018-03-01

    Automatic and accurate identification of rolling bearings fault categories, especially for the fault severities and fault orientations, is still a major challenge in rotating machinery fault diagnosis. In this paper, a novel method called ensemble deep auto-encoders (EDAEs) is proposed for intelligent fault diagnosis of rolling bearings. Firstly, different activation functions are employed as the hidden functions to design a series of auto-encoders (AEs) with different characteristics. Secondly, EDAEs are constructed with various auto-encoders for unsupervised feature learning from the measured vibration signals. Finally, a combination strategy is designed to ensure accurate and stable diagnosis results. The proposed method is applied to analyze the experimental bearing vibration signals. The results confirm that the proposed method can get rid of the dependence on manual feature extraction and overcome the limitations of individual deep learning models, which is more effective than the existing intelligent diagnosis methods.

  16. SU-E-J-220: Evaluation of Atlas-Based Auto-Segmentation (ABAS) in Head-And-Neck Adaptive Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Q; Yan, D

    2014-06-01

    Purpose: Evaluate the accuracy of atlas-based auto segmentation of organs at risk (OARs) on both helical CT (HCT) and cone beam CT (CBCT) images in head and neck (HN) cancer adaptive radiotherapy (ART). Methods: Six HN patients treated in the ART process were included in this study. For each patient, three images were selected: pretreatment planning CT (PreTx-HCT), in treatment CT for replanning (InTx-HCT) and a CBCT acquired in the same day of the InTx-HCT. Three clinical procedures of auto segmentation and deformable registration performed in the ART process were evaluated: a) auto segmentation on PreTx-HCT using multi-subject atlases, b)more » intra-patient propagation of OARs from PreTx-HCT to InTx-HCT using deformable HCT-to-HCT image registration, and c) intra-patient propagation of OARs from PreTx-HCT to CBCT using deformable CBCT-to-HCT image registration. Seven OARs (brainstem, cord, L/R parotid, L/R submandibular gland and mandible) were manually contoured on PreTx-HCT and InTx-HCT for comparison. In addition, manual contours on InTx-CT were copied on the same day CBCT, and a local region rigid body registration was performed accordingly for each individual OAR. For procedures a) and b), auto contours were compared to manual contours, and for c) auto contours were compared to those rigidly transferred contours on CBCT. Dice similarity coefficients (DSC) and mean surface distances of agreement (MSDA) were calculated for evaluation. Results: For procedure a), the mean DSC/MSDA of most OARs are >80%/±2mm. For intra-patient HCT-to-HCT propagation, the Resultimproved to >85%/±1.5mm. Compared to HCT-to-HCT, the mean DSC for HCT-to-CBCT propagation drops ∼2–3% and MSDA increases ∼0.2mm. This Resultindicates that the inferior imaging quality of CBCT seems only degrade auto propagation performance slightly. Conclusion: Auto segmentation and deformable propagation can generate OAR structures on HCT and CBCT images with clinically acceptable accuracy

  17. Reflector automatic acquisition and pointing based on auto-collimation theodolite.

    PubMed

    Luo, Jun; Wang, Zhiqian; Wen, Zhuoman; Li, Mingzhu; Liu, Shaojin; Shen, Chengwu

    2018-01-01

    An auto-collimation theodolite (ACT) for reflector automatic acquisition and pointing is designed based on the principle of autocollimators and theodolites. First, the principle of auto-collimation and theodolites is reviewed, and then the coaxial ACT structure is developed. Subsequently, the acquisition and pointing strategies for reflector measurements are presented, which first quickly acquires the target over a wide range and then points the laser spot to the charge coupled device zero position. Finally, experiments are conducted to verify the acquisition and pointing performance, including the calibration of the ACT, the comparison of the acquisition mode and pointing mode, and the accuracy measurement in horizontal and vertical directions. In both directions, a measurement accuracy of ±3″ is achieved. The presented ACT is suitable for automatic pointing and monitoring the reflector over a small scanning area and can be used in a wide range of applications such as bridge structure monitoring and cooperative target aiming.

  18. Reflector automatic acquisition and pointing based on auto-collimation theodolite

    NASA Astrophysics Data System (ADS)

    Luo, Jun; Wang, Zhiqian; Wen, Zhuoman; Li, Mingzhu; Liu, Shaojin; Shen, Chengwu

    2018-01-01

    An auto-collimation theodolite (ACT) for reflector automatic acquisition and pointing is designed based on the principle of autocollimators and theodolites. First, the principle of auto-collimation and theodolites is reviewed, and then the coaxial ACT structure is developed. Subsequently, the acquisition and pointing strategies for reflector measurements are presented, which first quickly acquires the target over a wide range and then points the laser spot to the charge coupled device zero position. Finally, experiments are conducted to verify the acquisition and pointing performance, including the calibration of the ACT, the comparison of the acquisition mode and pointing mode, and the accuracy measurement in horizontal and vertical directions. In both directions, a measurement accuracy of ±3″ is achieved. The presented ACT is suitable for automatic pointing and monitoring the reflector over a small scanning area and can be used in a wide range of applications such as bridge structure monitoring and cooperative target aiming.

  19. Efficacy of Bilevel-auto Treatment in Patients with Obstructive Sleep Apnea Not Responsive to or Intolerant of Continuous Positive Airway Pressure Ventilation.

    PubMed

    Carlucci, Annalisa; Ceriana, Piero; Mancini, Marco; Cirio, Serena; Pierucci, Paola; D'Artavilla Lupo, Nadia; Gadaleta, Felice; Morrone, Elisa; Fanfulla, Francesco

    2015-09-15

    Ventilation with continuous positive airway pressure (CPAP) is the gold standard therapy for obstructive sleep apnea (OSA). However, it was recently suggested that a novel mode of ventilation, Bilevel-auto, could be equally effective in treating patients unable to tolerate CPAP. The aim of this study was to investigate the ability of Bilevel-auto to treat OSA patients whose nocturnal ventilatory disturbances are not completely corrected by CPAP. We enrolled 66 consecutive OSA patients, not responsive to (group A) or intolerant of (group B) CPAP treatment, after a full night of manual CPAP titration in a laboratory. Full polysomnography data and daytime sleepiness score were compared for each group in the three different conditions: basal, during CPAP, and during Bilevel-auto. The apnea-hypopnea index decreased significantly during CPAP in both groups; however, in the group A, there was a further significant improvement during Bilevel-auto. The same trend was observed for oxygenation indices, while the distribution and the efficiency of sleep did not differ following the switch from CPAP to Bilevel-auto. This study confirmed the role of Bilevel-auto as an effective therapeutic alternative to CPAP in patients intolerant of this latter mode of ventilation. Moreover, extending the use of Bilevel-auto to those OSA patients not responsive to CPAP, we showed a significantly better correction of nocturnal respiratory disturbances. © 2015 American Academy of Sleep Medicine.

  20. Auto Mechanics I. Learning Activity Packets (LAPs). Section D--Suspension.

    ERIC Educational Resources Information Center

    Oklahoma State Board of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This document contains six learning activity packets (LAPs) that outline the study activities for the "suspension" instructional area for an Auto Mechanics I course. The six LAPs cover the following topics: wheel bearings, tires and wheels, wheel balancing, suspension system, steering system, and wheel alignment. Each LAP contains a…

  1. The nucleosomal acidic patch relieves auto-inhibition by the ISWI remodeler SNF2h

    PubMed Central

    Gamarra, Nathan; Johnson, Stephanie L; Trnka, Michael J; Burlingame, Alma L

    2018-01-01

    ISWI family chromatin remodeling motors use sophisticated autoinhibition mechanisms to control nucleosome sliding. Yet how the different autoinhibitory domains are regulated is not well understood. Here we show that an acidic patch formed by histones H2A and H2B of the nucleosome relieves the autoinhibition imposed by the AutoN and the NegC regions of the human ISWI remodeler SNF2h. Further, by single molecule FRET we show that the acidic patch helps control the distance travelled per translocation event. We propose a model in which the acidic patch activates SNF2h by providing a landing pad for the NegC and AutoN auto-inhibitory domains. Interestingly, the INO80 complex is also strongly dependent on the acidic patch for nucleosome sliding, indicating that this substrate feature can regulate remodeling enzymes with substantially different mechanisms. We therefore hypothesize that regulating access to the acidic patch of the nucleosome plays a key role in coordinating the activities of different remodelers in the cell. PMID:29664398

  2. Eco-Material Selection for Auto Bodies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mayyas, Ahmad T; Omar, Mohammed; Hayajneh, Mohammed T.

    In the last decades, majority of automakers started to include lightweight materials in their vehicles to meet hard environmental regulations and to improve fuel efficiency of their vehicles. As a result, eco-material selection for vehicles emerged as a new discipline under design for environment. This chapter will summarize methods of eco-material selections for automotive applications with more emphasis into auto-bodies. A set of metrics for eco-material selection that takes into account all economic, environmental and social factors will be developed using numerical and qualitative methods. These metrics cover products' environmental impact, functionality and manufacturability, in addition to the economic andmore » societal factors.« less

  3. The feasibility of the auto tuning respiratory compensation system with ultrasonic image tracking technique.

    PubMed

    Chuang, Ho-Chiao; Hsu, Hsiao-Yu; Nieh, Shu-Kan; Tien, Der-Chi

    2015-01-01

    The purpose of this study is to assess the feasibility of using the analytical technique of ultrasound images in combination with an auto tumor localization system. During respiration, the activity of breathing in and out causes organs displacement at the lower lobe of the lung, and the maximum displacement range happens in the Superior-Inferior (SI) direction. Therefore, in this study all the tumor positioning is in SI direction under respiratory compensation, in which the compensations are carried out to the organs at the lower lobe and adjacent to the lower lobe of lung.In this research, due to the processes of ultrasound imaging generation, image analysis and signal transmission, when the captured respiratory signals are sent to auto tumor localization system, there was a signal time delay. The total delay time of the entire signal transmission process was 0.254 ± 0.023 seconds (with the lowest standard deviation) after implementing a series of analyses. To compensate for this signal delay time (0.254 ± 0.023 sec), a phase lead compensator (PLC) was designed and built into the auto tumor localization system. By analyzing the impact of the delay time and the respiratory waveforms under different frequencies on the phase lead compensator, an overall system delay time can be configured. Results showed as the respiratory frequency increased, variable value ``a'' and the subsequent gain ``k'' in the controller becomes larger. Moreover, value ``a'' and ``k'' increased as the system delay time increased when the respiratory frequency was fixed. The relationship of value ``a'' and ``k'' to the respiratory frequency can be obtained by using the curve fitting method to compensate for the respiratory motion for tumor localization. Through the comparison of the uncompensated signal and the compensated signal performed by the auto tumor localization system on the simulated respiratory signal, the feasibility of using ultrasound image analysis technology combined with the

  4. Secretary Chu Speaks at the 2010 Washington Auto Show

    ScienceCinema

    Secretary Chu

    2017-12-09

    Secretary Chu lays out a roadmap for how the U.S. can lead the world in making the clean vehicles we need at the 2010 Washington Auto Show. He also announced that the Department of Energy had closed on a $1.4 billion loan to Nissan to build the all-electric LEAF in Tennessee and create up to 1,300 American jobs.

  5. Intraoperative Near-infrared Imaging for Parathyroid Gland Identification by Auto-fluorescence: A Feasibility Study.

    PubMed

    De Leeuw, Frederic; Breuskin, Ingrid; Abbaci, Muriel; Casiraghi, Odile; Mirghani, Haïtham; Ben Lakhdar, Aïcha; Laplace-Builhé, Corinne; Hartl, Dana

    2016-09-01

    Parathyroid glands (PGs) can be particularly hard to distinguish from surrounding tissue and thus can be damaged or removed during thyroidectomy. Postoperative hypoparathyroidism is the most common complication after thyroidectomy. Very recently, it has been found that the parathyroid tissue shows near-infrared (NIR) auto-fluorescence which could be used for intraoperative detection, without any use of contrast agents. The work described here presents a histological validation ex vivo of the NIR imaging procedure and evaluates intraoperative PG detection by NIR auto-fluorescence using for the first time to our knowledge a commercially available clinical NIR imaging device. Ex vivo study on resected operative specimens combined with a prospective in vivo study of consecutive patients who underwent total or partial thyroid, or parathyroid surgery at a comprehensive cancer center. During surgery, any tissue suspected to be a potential PG by the surgeon was imaged with the Fluobeam 800 (®) system. NIR imaging was compared to conventional histology (ex vivo) and/or visual identification by the surgeon (in vivo). We have validated NIR auto-fluorescence with an ex vivo study including 28 specimens. Sensitivity and specificity were 94.1 and 80 %, respectively. Intraoperative NIR imaging was performed in 35 patients and 81 parathyroids were identified. In 80/81 cases, the fluorescence signal was subjectively obvious on real-time visualization. We determined that PG fluorescence is 2.93 ± 1.59 times greater than thyroid fluorescence in vivo. Real-time NIR imaging based on parathyroid auto-fluorescence is fast, safe, and non-invasive and shows very encouraging results, for intraoperative parathyroid identification.

  6. Auto Mechanics I. Learning Activity Packets (LAPs). Section C--Engine.

    ERIC Educational Resources Information Center

    Oklahoma State Board of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This document contains five learning activity packets (LAPs) that outline the study activities for the "engine" instructional area for an Auto Mechanics I course. The five LAPs cover the following topics: basic engine principles, cooling system, engine lubrication system, exhaust system, and fuel system. Each LAP contains a cover sheet…

  7. [Implementation and evaluation of a teaching plan for the auto-irrigation of colostomy: a case study].

    PubMed

    Costa, Idevânia Geraldina; Maruyama, Sônia Ayako Tao

    2004-01-01

    With a view to describing and evaluating the implementation of a teaching plan for the auto-irrigation of colostomy and reporting on the perceptions of colostomized patients related to auto-irrigation, this case study was developed at the colostomy out-patient clinic of the Júlio Müller University Hospital, Cuiabá, Brazil, from February to March 1997. The teaching plan helped the patients to learn about the irrigation technique and social rehabilitation.

  8. Validation of a Magnetic Resonance Imaging-based Auto-contouring Software Tool for Gross Tumour Delineation in Head and Neck Cancer Radiotherapy Planning.

    PubMed

    Doshi, T; Wilson, C; Paterson, C; Lamb, C; James, A; MacKenzie, K; Soraghan, J; Petropoulakis, L; Di Caterina, G; Grose, D

    2017-01-01

    To carry out statistical validation of a newly developed magnetic resonance imaging (MRI) auto-contouring software tool for gross tumour volume (GTV) delineation in head and neck tumours to assist in radiotherapy planning. Axial MRI baseline scans were obtained for 10 oropharyngeal and laryngeal cancer patients. GTV was present on 102 axial slices and auto-contoured using the modified fuzzy c-means clustering integrated with the level set method (FCLSM). Peer-reviewed (C-gold) manual contours were used as the reference standard to validate auto-contoured GTVs (C-auto) and mean manual contours (C-manual) from two expert clinicians (C1 and C2). Multiple geometric metrics, including the Dice similarity coefficient (DSC), were used for quantitative validation. A DSC≥0.7 was deemed acceptable. Inter- and intra-variabilities among the manual contours were also validated. The two-dimensional contours were then reconstructed in three dimensions for GTV volume calculation, comparison and three-dimensional visualisation. The mean DSC between C-gold and C-auto was 0.79. The mean DSC between C-gold and C-manual was 0.79 and that between C1 and C2 was 0.80. The average time for GTV auto-contouring per patient was 8 min (range 6-13 min; mean 45 s per axial slice) compared with 15 min (range 6-23 min; mean 88 s per axial slice) for C1. The average volume concordance between C-gold and C-auto volumes was 86.51% compared with 74.16% between C-gold and C-manual. The average volume concordance between C1 and C2 volumes was 86.82%. This newly designed MRI-based auto-contouring software tool shows initial acceptable results in GTV delineation of oropharyngeal and laryngeal tumours using FCLSM. This auto-contouring software tool may help reduce inter- and intra-variability and can assist clinical oncologists with time-consuming, complex radiotherapy planning. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. Use of individual auto-injector kits ‘IZAS-05’ on the contemporary battlefield

    PubMed Central

    Ziemba, Radosław

    2012-01-01

    Summary In crisis situations, such as transportation catastrophes, terrorist attacks or contamination with chemical warfare agents, it is crucial to properly organize and sensibly conduct rescue operations. Among chemical warfare agents, the most toxic ones are the derivatives of organophosphorus compounds. An individual auto-injector kit ‘IZAS-05’ contains auto-injectors, which are devices designed for intramuscular administration of drugs in self-aid or buddy-aid on the battlefield. This paper describes in detail the components of the ‘IZAS-05’ kit, as well as its mode of use and possible contraindications. PMID:22207129

  10. An Adaptor Domain-Mediated Auto-Catalytic Interfacial Kinase Reaction

    PubMed Central

    Liao, Xiaoli; Su, Jing; Mrksich, Milan

    2010-01-01

    This paper describes a model system for studying the auto-catalytic phosphorylation of an immobilized substrate by a kinase enzyme. This work uses self-assembled monolayers (SAMs) of alkanethiolates on gold to present the peptide substrate on a planar surface. Treatment of the monolayer with Abl kinase results in phosphorylation of the substrate. The phosphorylated peptide then serves as a ligand for the SH2 adaptor domain of the kinase and thereby directs the kinase activity to nearby peptide substrates. This directed reaction is intramolecular and proceeds with a faster rate than does the initial, intermolecular reaction, making this an auto-catalytic process. The kinetic non-linearity gives rise to properties that have no counterpart in the corresponding homogeneous phase reaction: in one example, the rate for phosphorylation of a mixture of two peptides is faster than the sum of the rates for phosphorylation of each peptide when presented alone. This work highlights the use of an adaptor domain in modulating the activity of a kinase enzyme for an immobilized substrate and offers a new approach for studying biochemical reactions in spatially inhomogeneous settings. PMID:19821459

  11. Development and validation of an automated delirium risk assessment system (Auto-DelRAS) implemented in the electronic health record system.

    PubMed

    Moon, Kyoung-Ja; Jin, Yinji; Jin, Taixian; Lee, Sun-Mi

    2018-01-01

    A key component of the delirium management is prevention and early detection. To develop an automated delirium risk assessment system (Auto-DelRAS) that automatically alerts health care providers of an intensive care unit (ICU) patient's delirium risk based only on data collected in an electronic health record (EHR) system, and to evaluate the clinical validity of this system. Cohort and system development designs were used. Medical and surgical ICUs in two university hospitals in Seoul, Korea. A total of 3284 patients for the development of Auto-DelRAS, 325 for external validation, 694 for validation after clinical applications. The 4211 data items were extracted from the EHR system and delirium was measured using CAM-ICU (Confusion Assessment Method for Intensive Care Unit). The potential predictors were selected and a logistic regression model was established to create a delirium risk scoring algorithm to construct the Auto-DelRAS. The Auto-DelRAS was evaluated at three months and one year after its application to clinical practice to establish the predictive validity of the system. Eleven predictors were finally included in the logistic regression model. The results of the Auto-DelRAS risk assessment were shown as high/moderate/low risk on a Kardex screen. The predictive validity, analyzed after the clinical application of Auto-DelRAS after one year, showed a sensitivity of 0.88, specificity of 0.72, positive predictive value of 0.53, negative predictive value of 0.94, and a Youden index of 0.59. A relatively high level of predictive validity was maintained with the Auto-DelRAS system, even one year after it was applied to clinical practice. Copyright © 2017. Published by Elsevier Ltd.

  12. Multi-atlas segmentation of subcortical brain structures via the AutoSeg software pipeline

    PubMed Central

    Wang, Jiahui; Vachet, Clement; Rumple, Ashley; Gouttard, Sylvain; Ouziel, Clémentine; Perrot, Emilie; Du, Guangwei; Huang, Xuemei; Gerig, Guido; Styner, Martin

    2014-01-01

    Automated segmenting and labeling of individual brain anatomical regions, in MRI are challenging, due to the issue of individual structural variability. Although atlas-based segmentation has shown its potential for both tissue and structure segmentation, due to the inherent natural variability as well as disease-related changes in MR appearance, a single atlas image is often inappropriate to represent the full population of datasets processed in a given neuroimaging study. As an alternative for the case of single atlas segmentation, the use of multiple atlases alongside label fusion techniques has been introduced using a set of individual “atlases” that encompasses the expected variability in the studied population. In our study, we proposed a multi-atlas segmentation scheme with a novel graph-based atlas selection technique. We first paired and co-registered all atlases and the subject MR scans. A directed graph with edge weights based on intensity and shape similarity between all MR scans is then computed. The set of neighboring templates is selected via clustering of the graph. Finally, weighted majority voting is employed to create the final segmentation over the selected atlases. This multi-atlas segmentation scheme is used to extend a single-atlas-based segmentation toolkit entitled AutoSeg, which is an open-source, extensible C++ based software pipeline employing BatchMake for its pipeline scripting, developed at the Neuro Image Research and Analysis Laboratories of the University of North Carolina at Chapel Hill. AutoSeg performs N4 intensity inhomogeneity correction, rigid registration to a common template space, automated brain tissue classification based skull-stripping, and the multi-atlas segmentation. The multi-atlas-based AutoSeg has been evaluated on subcortical structure segmentation with a testing dataset of 20 adult brain MRI scans and 15 atlas MRI scans. The AutoSeg achieved mean Dice coefficients of 81.73% for the subcortical structures

  13. Auto-Photography as Research Practice: Identity and Self-Esteem Research

    ERIC Educational Resources Information Center

    Noland, Carey M.

    2006-01-01

    This paper explores auto-photography as a form of research practice in the area of identity and self-esteem research. It allows researchers to capture and articulate the ways identity guides human action and thought. It involves the generation and examination of the static images that participants themselves believe best represent them.…

  14. Can we still dream when the mind is blank? Sleep and dream mentations in auto-activation deficit.

    PubMed

    Leu-Semenescu, Smaranda; Uguccioni, Ginevra; Golmard, Jean-Louis; Czernecki, Virginie; Yelnik, Jerome; Dubois, Bruno; Forgeot d'Arc, Baudouin; Grabli, David; Levy, Richard; Arnulf, Isabelle

    2013-10-01

    Bilateral damage to the basal ganglia causes auto-activation deficit, a neuropsychological syndrome characterized by striking apathy, with a loss of self-driven behaviour that is partially reversible with external stimulation. Some patients with auto-activation deficit also experience a mental emptiness, which is defined as an absence of any self-reported thoughts. We asked whether this deficit in spontaneous activation of mental processing may be reversed during REM sleep, when dreaming activity is potentially elicited by bottom-up brainstem stimulation on the cortex. Sleep and video monitoring over two nights and cognitive tests were performed on 13 patients with auto-activation deficit secondary to bilateral striato-pallidal lesions and 13 healthy subjects. Dream mentations were collected from home diaries and after forced awakenings in non-REM and REM sleep. The home diaries were blindly analysed for length, complexity and bizarreness. A mental blank during wakefulness was complete in six patients and partial in one patient. Four (31%) patients with auto-activation deficit (versus 92% of control subjects) reported mentations when awakened from REM sleep, even when they demonstrated a mental blank during the daytime (n = 2). However, the patients' dream reports were infrequent, short, devoid of any bizarre or emotional elements and tended to be less complex than the dream mentations of control subjects. The sleep duration, continuity and stages were similar between the groups, except for a striking absence of sleep spindles in 6 of 13 patients with auto-activation deficit, despite an intact thalamus. The presence of spontaneous dreams in REM sleep in the absence of thoughts during wakefulness in patients with auto-activation deficit supports the idea that simple dream imagery is generated by brainstem stimulation and is sent to the sensory cortex. However, the lack of complexity in these dream mentations suggests that the full dreaming process (scenario

  15. O-desmethylquinine as a cyclooxygenase-2 (COX-2) inhibitors using AutoDock Vina

    NASA Astrophysics Data System (ADS)

    Damayanti, Sophi; Mahardhika, Andhika Bintang; Ibrahim, Slamet; Chong, Wei Lim; Lee, Vannajan Sanghiran; Tjahjono, Daryono Hadi

    2014-10-01

    Computational approach was employed to evaluate the biological activity of novel cyclooxygenase-2 COX-2 inhibitor, O-desmethylquinine, in comparison to quinine as common inhibitor which can also be used an agent of antipyretic, antimalaria, analgesic and antiinflamation. The molecular models of the compound were constructed and optimized with the density function theory with at the B3LYP/6-31G (d,p) level using Gaussian 09 program. Molecular docking studies of the compounds were done to obtain the COX-2 complex structures and their binding energies were analyzed using the AutoDock Vina. The results of docking of the two ligands were comparable and cannot be differentiated from the energy scoring function with AutoDock Vina.

  16. Prototype and Evaluation of AutoHelp: A Case-based, Web-accessible Help Desk System for EOSDIS

    NASA Technical Reports Server (NTRS)

    Mitchell, Christine M.; Thurman, David A.

    1999-01-01

    AutoHelp is a case-based, Web-accessible help desk for users of the EOSDIS. Its uses a combination of advanced computer and Web technologies, knowledge-based systems tools, and cognitive engineering to offload the current, person-intensive, help desk facilities at the DAACs. As a case-based system, AutoHelp starts with an organized database of previous help requests (questions and answers) indexed by a hierarchical category structure that facilitates recognition by persons seeking assistance. As an initial proof-of-concept demonstration, a month of email help requests to the Goddard DAAC were analyzed and partially organized into help request cases. These cases were then categorized to create a preliminary case indexing system, or category structure. This category structure allows potential users to identify or recognize categories of questions, responses, and sample cases similar to their needs. Year one of this research project focused on the development of a technology demonstration. User assistance 'cases' are stored in an Oracle database in a combination of tables linking prototypical questions with responses and detailed examples from the email help requests analyzed to date. When a potential user accesses the AutoHelp system, a Web server provides a Java applet that displays the category structure of the help case base organized by the needs of previous users. When the user identifies or requests a particular type of assistance, the applet uses Java database connectivity (JDBC) software to access the database and extract the relevant cases. The demonstration will include an on-line presentation of how AutoHelp is currently structured. We will show how a user might request assistance via the Web interface and how the AutoHelp case base provides assistance. The presentation will describe the DAAC data collection, case definition, and organization to date, as well as the AutoHelp architecture. It will conclude with the year 2 proposal to more fully develop the

  17. Efficacy of Bilevel-auto Treatment in Patients with Obstructive Sleep Apnea Not Responsive to or Intolerant of Continuous Positive Airway Pressure Ventilation

    PubMed Central

    Carlucci, Annalisa; Ceriana, Piero; Mancini, Marco; Cirio, Serena; Pierucci, Paola; D'Artavilla Lupo, Nadia; Gadaleta, Felice; Morrone, Elisa; Fanfulla, Francesco

    2015-01-01

    Background: Ventilation with continuous positive airway pressure (CPAP) is the gold standard therapy for obstructive sleep apnea (OSA). However, it was recently suggested that a novel mode of ventilation, Bilevel-auto, could be equally effective in treating patients unable to tolerate CPAP. The aim of this study was to investigate the ability of Bilevel-auto to treat OSA patients whose nocturnal ventilatory disturbances are not completely corrected by CPAP. Methods: We enrolled 66 consecutive OSA patients, not responsive to (group A) or intolerant of (group B) CPAP treatment, after a full night of manual CPAP titration in a laboratory. Full polysomnography data and daytime sleepiness score were compared for each group in the three different conditions: basal, during CPAP, and during Bilevel-auto. Results: The apnea-hypopnea index decreased significantly during CPAP in both groups; however, in the group A, there was a further significant improvement during Bilevel-auto. The same trend was observed for oxygenation indices, while the distribution and the efficiency of sleep did not differ following the switch from CPAP to Bilevel-auto. Conclusions: This study confirmed the role of Bilevel-auto as an effective therapeutic alternative to CPAP in patients intolerant of this latter mode of ventilation. Moreover, extending the use of Bilevel-auto to those OSA patients not responsive to CPAP, we showed a significantly better correction of nocturnal respiratory disturbances. Citation: Carlucci A, Ceriana P, Mancini M, Cirio S, Pierucci P, D'Artavilla Lupo N, Gadaleta F, Morrone E, Fanfulla F. Efficacy of Bilevel-auto treatment in patients with obstructive sleep apnea not responsive to or intolerant of continuous positive airway pressure ventilation. J Clin Sleep Med 2015;11(9):981–985. PMID:25902825

  18. 77 FR 27108 - Order of Suspension of Trading; In the Matter of Anthracite Capital, Inc., Auto Data Network Inc...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-08

    ... of Anthracite Capital, Inc., Auto Data Network Inc., Avenue Group, Inc., Ckrush, Inc., Clickable... securities of Auto Data Network Inc. because it has not filed any periodic reports since the period ended... accurate information concerning the securities of Avenue Group, Inc. because it has not filed any periodic...

  19. An Art Educator's Journey of Becoming a Researcher: A Self-Reflective Auto-Ethnography of Identity Construction and Personal Growth

    ERIC Educational Resources Information Center

    Riedler, Martina

    2016-01-01

    In this self-reflective auto-ethnographic research, the author shares her experiences of introspection, change and professional growth as an art educator in an international context. Auto-ethnography is an approach to qualitative inquiry in which the researcher employs self-reflection to explore her personal experiences and connect these…

  20. A lack of association between hyperserotonemia and the increased frequency of serum anti-myelin basic protein auto-antibodies in autistic children.

    PubMed

    Mostafa, Gehan Ahmed; Al-Ayadhi, Laila Yousef

    2011-06-22

    One of the most consistent biological findings in autism is the elevated blood serotonin levels. Immune abnormalities, including autoimmunity with production of brain specific auto-antibodies, are also commonly observed in this disorder. Hyperserotonemia may be one of the contributing factors to autoimmunity in some patients with autism through the reduction of T-helper (Th) 1-type cytokines. We are the first to investigate the possible role of hyperserotonemia in the induction of autoimmunity, as indicated by serum anti-myelin-basic protein (anti-MBP) auto-antibodies, in autism. Serum levels of serotonin and anti-MBP auto-antibodies were measured, by ELISA, in 50 autistic patients, aged between 5 and 12 years, and 30 healthy-matched children. Autistic children had significantly higher serum levels of serotonin and anti-MBP auto-antibodies than healthy children (P < 0.001 and P < 0.001, respectively). Increased serum levels of serotonin and anti-MBP auto-antibodies were found in 92% and 80%, respectively of autistic patients. Patients with severe autism had significantly higher serum serotonin levels than children with mild to moderate autism (P < 0.001). Serum serotonin levels had no significant correlations with serum levels of anti-MBP auto-antibodies in autistic patients (P = 0.39). Hyperserotonemia may not be one of the contributing factors to the increased frequency of serum anti-MBP auto-antibodies in some autistic children. These data should be treated with caution until further investigations are performed. However, inclusion of serum serotonin levels as a correlate may be useful in other future immune studies in autism to help unravel the long-standing mystery of hyperserotonemia and its possible role in the pathophysiology of this disorder.

  1. 21st Century Curriculum: Does Auto-Grading Writing Actually Work?

    ERIC Educational Resources Information Center

    T.H.E. Journal, 2013

    2013-01-01

    The West Virginia Department of Education's auto grading initiative dates back to 2004--a time when school districts were making their first forays into automation. The Charleston based WVDE had instituted a statewide writing assessment in 1984 for students in fourth, seventh, and 10th grades and was looking to expand that program without having…

  2. EFFECTS OF BRANCHING IN A COMPUTER-CONTROLLED AUTO-INSTRUCTIONAL DEVICE.

    ERIC Educational Resources Information Center

    COULSON, JOHN E.; AND OTHERS

    A STUDY ON THE EFFECTIVENESS OF USING BOTH THE STUDENT'S ERRORS ON TRAINING ITEMS AND HIS OWN EVALUATION OF HIS LEARNING PROGRESS WAS PRESENTED. TWO GROUPS OF 15 HIGH SCHOOL STUDENTS WERE GIVEN AUTOMATED INSTRUCTION ON LOGIC BY MEANS OF A FLEXIBLE SEQUENCE, COMPUTER-CONTROLLED AUTO-INSTRUCTIONAL DEVICE. ONE GROUP WAS DESIGNATED THE FIXED-SEQUENCE…

  3. In vivo determination of root canal length: a preliminary report using the Tri Auto ZX apex-locating handpiece.

    PubMed

    Grimberg, F; Banegas, G; Chiacchio, L; Zmener, O

    2002-07-01

    The aim of this study was to assess the clinical perfomance of a cordless handpiece with a built-in apex locator - the Tri Auto ZX - designed for root canal preparation with nickel-titanium rotary files. Twenty-five human maxillary incisor and canine teeth scheduled for extraction with mature apices were selected for the study. Informed written consent was obtained from each patient before treatment. After administration of local anaesthesia, the teeth were isolated and the pulp cavities accessed. The Tri Auto ZX along with a size 15 K-file was used in its electronic apex locating function based on the manufacturer's recommendations. A periapical radiograph with the file at the electronically determined constriction was taken, the file removed and the measurement registered as the electronic length (EL). To test the auto reverse function, a size 20 ProFile.04 taper NiTi rotary instrument was mounted in the handpiece. The point for the auto apical reverse function was preset on the panel at the 0.5 mm level. After the file was introduced into the canal and reached the predetermined level, the file automatically stopped and rotated in the opposite direction. A reference point was marked and this measurement was registered as the auto reverse length (ARL). All measurements were made twice by two different investigators. Teeth were then extracted and immersed in a 20% formalin solution for 48 h. After fixation, a size 15 file was inserted into the canal to measure the actual root canal length from the same reference point obtained with the Tri Auto ZX to the apical foramen, as seen in the stereo microscope. When the file tip was visible at the anatomical end of the canal it was withdrawn 0.5 mm and this measurement was registered as the actual length (AL). All measurements were expressed in mm and the measuring accuracy was set to 0.5 mm. The significance of the mean differences between EL and ARL and between EL and AL measurements at the 5% confidence level was

  4. Construction and development of an auto-regulatory gene expression system in Bacillus subtilis.

    PubMed

    Guan, Chengran; Cui, Wenjing; Cheng, Jintao; Zhou, Li; Guo, Junling; Hu, Xu; Xiao, Guoping; Zhou, Zhemin

    2015-09-21

    Bacillus subtilis is an all-important Gram-positive bacterium of valuable biotechnological utility that has been widely used to over-produce industrially and pharmaceutically relevant proteins. There are a variety of expression systems in terms of types of transcriptional patterns, among which the auto-inducible and growth-phase-dependent promoters are gaining increasing favor due to their inducer-independent feature, allowing for the potential to industrially scale-up. To expand the applicability of the auto-inducible expression system, a novel auto-regulatory expression system coupled with cell density was constructed and developed in B. subtilis using the quorum-sensing related promoter srfA (PsrfA). The promoter of the srf operon was used to construct an expression plasmid with the green fluorescent protein (GFP) downstream of PsrfA. The expression displayed a cell-density-dependent pattern in that GFP had a fairly low expression level at the early exponential stage and was highly expressed at the late exponential as well as the stationary stages. Moreover, the recombinant system had a similar expression pattern in wild-type B. subtilis 168, WB600, and WB800, as well as in B. subtilis 168 derivative strain 1681, with the complete deletion of PsrfA, indicating the excellent compatibility of this system. Noticeably, the expression strength of PsrfA was enhanced by optimizing the -10 and -35 core sequence by substituting both sequences with consensus sequences. Importantly, the expression pattern was successfully developed in an auto-regulatory cell-density coupling system by the simple addition of glucose in which GFP could not be strongly expressed until glucose was depleted, resulting in a greater amount of the GFP product and increased cell density. The expression system was eventually tested by the successful over-production of aminopeptidase to a desired level. The auto-regulatory cell density coupling system that is mediated by PsrfA is a novel expression

  5. Permutation auto-mutual information of electroencephalogram in anesthesia

    NASA Astrophysics Data System (ADS)

    Liang, Zhenhu; Wang, Yinghua; Ouyang, Gaoxiang; Voss, Logan J.; Sleigh, Jamie W.; Li, Xiaoli

    2013-04-01

    Objective. The dynamic change of brain activity in anesthesia is an interesting topic for clinical doctors and drug designers. To explore the dynamical features of brain activity in anesthesia, a permutation auto-mutual information (PAMI) method is proposed to measure the information coupling of electroencephalogram (EEG) time series obtained in anesthesia. Approach. The PAMI is developed and applied on EEG data collected from 19 patients under sevoflurane anesthesia. The results are compared with the traditional auto-mutual information (AMI), SynchFastSlow (SFS, derived from the BIS index), permutation entropy (PE), composite PE (CPE), response entropy (RE) and state entropy (SE). Performance of all indices is assessed by pharmacokinetic/pharmacodynamic (PK/PD) modeling and prediction probability. Main results. The PK/PD modeling and prediction probability analysis show that the PAMI index correlates closely with the anesthetic effect. The coefficient of determination R2 between PAMI values and the sevoflurane effect site concentrations, and the prediction probability Pk are higher in comparison with other indices. The information coupling in EEG series can be applied to indicate the effect of the anesthetic drug sevoflurane on the brain activity as well as other indices. The PAMI of the EEG signals is suggested as a new index to track drug concentration change. Significance. The PAMI is a useful index for analyzing the EEG dynamics during general anesthesia.

  6. Towards Verification of Operational Procedures Using Auto-Generated Diagnostic Trees

    NASA Technical Reports Server (NTRS)

    Kurtoglu, Tolga; Lutz, Robyn; Patterson-Hine, Ann

    2009-01-01

    The design, development, and operation of complex space, lunar and planetary exploration systems require the development of general procedures that describe a detailed set of instructions capturing how mission tasks are performed. For both crewed and uncrewed NASA systems, mission safety and the accomplishment of the scientific mission objectives are highly dependent on the correctness of procedures. In this paper, we describe how to use the auto-generated diagnostic trees from existing diagnostic models to improve the verification of standard operating procedures. Specifically, we introduce a systematic method, namely the Diagnostic Tree for Verification (DTV), developed with the goal of leveraging the information contained within auto-generated diagnostic trees in order to check the correctness of procedures, to streamline the procedures in terms of reducing the number of steps or use of resources in them, and to propose alternative procedural steps adaptive to changing operational conditions. The application of the DTV method to a spacecraft electrical power system shows the feasibility of the approach and its range of capabilities

  7. Porcine pulmonary auto-transplantation for ex vivo therapy as a model for new treatment strategies.

    PubMed

    Krüger, Marcus; Zinne, Norman; Biancosino, Christian; Höffler, Klaus; Rajab, Taufiek K; Waldmann, Karl-Heinz; Jonigk, Danny; Avsar, Murat; Haverich, Axel; Hoeltig, Doris

    2016-09-01

    Lung auto-transplantation is the surgical key step in experiments involving ex vivo therapy of severe or end-stage lung diseases. Ex vivo therapy has become a clinical reality because of systems such as the Organ Care System (OCS) Lung, which is the only commercially available portable lung perfusion system. However, survival experiments involving porcine lung auto-transplantation pose special surgical and anaesthesiological challenges. This current study was designed to describe the development of surgical techniques and aneasthesiological management strategies that facilitate lung auto-transplantation survival surgery including a follow-up period of 4 days. Left pneumonectomy was performed in 12 Mini-Lewe miniature pigs. After ex vivo treatment of the harvested lungs within the OCS Lung for 2 h, the lungs were retransplanted into the same animal (auto-transplantation). Four animals were used to develop the optimal techniques and establish an experimental protocol. According to the final protocol, eight additional animals were operated. The follow-up period was 4 days. There were four severe intraoperative surgical complications [anatomical variant of the superior vena cava (two times), a complication related to the bronchial anastomosis and a complication related to the pulmonary arterial anastomosis]. The major postoperative problems were hyperkalaemia, prolonged recovery from anaesthesia and pulmonary oedema after reperfusion. Establishment of the surgical technique showed that using a pericardial tube to facilitate the anastomosis of the thin left superior pulmonary vein should be considered to prevent thrombosis. However, routine use of the patch technique to construct venous and arterial anastomoses is not necessary. Furthermore, traction on the venous anastomoses can be avoided by performing the bronchial anastomosis first. Lung auto-transplantation is a feasible experimental model for ex vivo therapy of lung diseases and is applicable for experimental

  8. AutoSyP: A Low-Cost, Low-Power Syringe Pump for Use in Low-Resource Settings.

    PubMed

    Juarez, Alexa; Maynard, Kelley; Skerrett, Erica; Molyneux, Elizabeth; Richards-Kortum, Rebecca; Dube, Queen; Oden, Z Maria

    2016-10-05

    This article describes the design and evaluation of AutoSyP, a low-cost, low-power syringe pump intended to deliver intravenous (IV) infusions in low-resource hospitals. A constant-force spring within the device provides mechanical energy to depress the syringe plunger. As a result, the device can run on rechargeable battery power for 66 hours, a critical feature for low-resource settings where the power grid may be unreliable. The device is designed to be used with 5- to 60-mL syringes and can deliver fluids at flow rates ranging from 3 to 60 mL/hour. The cost of goods to build one AutoSyP device is approximately $500. AutoSyP was tested in a laboratory setting and in a pilot clinical study. Laboratory accuracy was within 4% of the programmed flow rate. The device was used to deliver fluid to 10 healthy adult volunteers and 30 infants requiring IV fluid therapy at Queen Elizabeth Central Hospital in Blantyre, Malawi. The device delivered fluid with an average mean flow rate error of -2.3% ± 1.9% for flow rates ranging from 3 to 60 mL/hour. AutoSyP has the potential to improve the accuracy and safety of IV fluid delivery in low-resource settings. © The American Society of Tropical Medicine and Hygiene.

  9. An asymptotic theory for cross-correlation between auto-correlated sequences and its application on neuroimaging data.

    PubMed

    Zhou, Yunyi; Tao, Chenyang; Lu, Wenlian; Feng, Jianfeng

    2018-04-20

    Functional connectivity is among the most important tools to study brain. The correlation coefficient, between time series of different brain areas, is the most popular method to quantify functional connectivity. Correlation coefficient in practical use assumes the data to be temporally independent. However, the time series data of brain can manifest significant temporal auto-correlation. A widely applicable method is proposed for correcting temporal auto-correlation. We considered two types of time series models: (1) auto-regressive-moving-average model, (2) nonlinear dynamical system model with noisy fluctuations, and derived their respective asymptotic distributions of correlation coefficient. These two types of models are most commonly used in neuroscience studies. We show the respective asymptotic distributions share a unified expression. We have verified the validity of our method, and shown our method exhibited sufficient statistical power for detecting true correlation on numerical experiments. Employing our method on real dataset yields more robust functional network and higher classification accuracy than conventional methods. Our method robustly controls the type I error while maintaining sufficient statistical power for detecting true correlation in numerical experiments, where existing methods measuring association (linear and nonlinear) fail. In this work, we proposed a widely applicable approach for correcting the effect of temporal auto-correlation on functional connectivity. Empirical results favor the use of our method in functional network analysis. Copyright © 2018. Published by Elsevier B.V.

  10. Method for auto-alignment of digital optical phase conjugation systems based on digital propagation

    PubMed Central

    Jang, Mooseok; Ruan, Haowen; Zhou, Haojiang; Judkewitz, Benjamin; Yang, Changhuei

    2014-01-01

    Optical phase conjugation (OPC) has enabled many optical applications such as aberration correction and image transmission through fiber. In recent years, implementation of digital optical phase conjugation (DOPC) has opened up the possibility of its use in biomedical optics (e.g. deep-tissue optical focusing) due to its ability to provide greater-than-unity OPC reflectivity (the power ratio of the phase conjugated beam and input beam to the OPC system) and its flexibility to accommodate additional wavefront manipulations. However, the requirement for precise (pixel-to-pixel matching) alignment of the wavefront sensor and the spatial light modulator (SLM) limits the practical usability of DOPC systems. Here, we report a method for auto-alignment of a DOPC system by which the misalignment between the sensor and the SLM is auto-corrected through digital light propagation. With this method, we were able to accomplish OPC playback with a DOPC system with gross sensor-SLM misalignment by an axial displacement of up to~1.5 cm, rotation and tip/tilt of ~5∘, and in-plane displacement of ~5 mm (dependent on the physical size of the sensor and the SLM). Our auto-alignment method robustly achieved a DOPC playback peak-to-background ratio (PBR) corresponding to more than ~30 % of the theoretical maximum. As an additional advantage, the auto-alignment procedure can be easily performed at will and, as such, allows us to correct for small mechanical drifts within the DOPC systems, thus overcoming a previously major DOPC system vulnerability. We believe that this reported method for implementing robust DOPC systems will broaden the practical utility of DOPC systems. PMID:24977504

  11. Method for auto-alignment of digital optical phase conjugation systems based on digital propagation.

    PubMed

    Jang, Mooseok; Ruan, Haowen; Zhou, Haojiang; Judkewitz, Benjamin; Yang, Changhuei

    2014-06-16

    Optical phase conjugation (OPC) has enabled many optical applications such as aberration correction and image transmission through fiber. In recent years, implementation of digital optical phase conjugation (DOPC) has opened up the possibility of its use in biomedical optics (e.g. deep-tissue optical focusing) due to its ability to provide greater-than-unity OPC reflectivity (the power ratio of the phase conjugated beam and input beam to the OPC system) and its flexibility to accommodate additional wavefront manipulations. However, the requirement for precise (pixel-to-pixel matching) alignment of the wavefront sensor and the spatial light modulator (SLM) limits the practical usability of DOPC systems. Here, we report a method for auto-alignment of a DOPC system by which the misalignment between the sensor and the SLM is auto-corrected through digital light propagation. With this method, we were able to accomplish OPC playback with a DOPC system with gross sensor-SLM misalignment by an axial displacement of up to~1.5 cm, rotation and tip/tilt of ~5° and in-plane displacement of ~5 mm (dependent on the physical size of the sensor and the SLM). Our auto-alignment method robustly achieved a DOPC playback peak-to-background ratio (PBR) corresponding to more than ~30 % of the theoretical maximum. As an additional advantage, the auto-alignment procedure can be easily performed at will and, as such, allows us to correct for small mechanical drifts within the DOPC systems, thus overcoming a previously major DOPC system vulnerability. We believe that this reported method for implementing robust DOPC systems will broaden the practical utility of DOPC systems.

  12. Optimal design of a high accuracy photoelectric auto-collimator based on position sensitive detector

    NASA Astrophysics Data System (ADS)

    Yan, Pei-pei; Yang, Yong-qing; She, Wen-ji; Liu, Kai; Jiang, Kai; Duan, Jing; Shan, Qiusha

    2018-02-01

    A kind of high accuracy Photo-electric auto-collimator based on PSD was designed. The integral structure composed of light source, optical lens group, Position Sensitive Detector (PSD) sensor, and its hardware and software processing system constituted. Telephoto objective optical type is chosen during the designing process, which effectively reduces the length, weight and volume of the optical system, as well as develops simulation-based design and analysis of the auto-collimator optical system. The technical indicators of auto-collimator presented by this paper are: measuring resolution less than 0.05″; a field of view is 2ω=0.4° × 0.4° measuring range is +/-5' error of whole range measurement is less than 0.2″. Measuring distance is 10m, which are applicable to minor-angle precise measuring environment. Aberration analysis indicates that the MTF close to the diffraction limit, the spot in the spot diagram is much smaller than the Airy disk. The total length of the telephoto lens is only 450mm by the design of the optical machine structure optimization. The autocollimator's dimension get compact obviously under the condition of the image quality is guaranteed.

  13. AutoSite: an automated approach for pseudo-ligands prediction—from ligand-binding sites identification to predicting key ligand atoms

    PubMed Central

    Ravindranath, Pradeep Anand; Sanner, Michel F.

    2016-01-01

    Motivation: The identification of ligand-binding sites from a protein structure facilitates computational drug design and optimization, and protein function assignment. We introduce AutoSite: an efficient software tool for identifying ligand-binding sites and predicting pseudo ligand corresponding to each binding site identified. Binding sites are reported as clusters of 3D points called fills in which every point is labelled as hydrophobic or as hydrogen bond donor or acceptor. From these fills AutoSite derives feature points: a set of putative positions of hydrophobic-, and hydrogen-bond forming ligand atoms. Results: We show that AutoSite identifies ligand-binding sites with higher accuracy than other leading methods, and produces fills that better matches the ligand shape and properties, than the fills obtained with a software program with similar capabilities, AutoLigand. In addition, we demonstrate that for the Astex Diverse Set, the feature points identify 79% of hydrophobic ligand atoms, and 81% and 62% of the hydrogen acceptor and donor hydrogen ligand atoms interacting with the receptor, and predict 81.2% of water molecules mediating interactions between ligand and receptor. Finally, we illustrate potential uses of the predicted feature points in the context of lead optimization in drug discovery projects. Availability and Implementation: http://adfr.scripps.edu/AutoDockFR/autosite.html Contact: sanner@scripps.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:27354702

  14. Megagauss-level magnetic field production in cm-scale auto-magnetizing helical liners pulsed to 500 kA in 125 ns

    NASA Astrophysics Data System (ADS)

    Shipley, G. A.; Awe, T. J.; Hutsel, B. T.; Slutz, S. A.; Lamppa, D. C.; Greenly, J. B.; Hutchinson, T. M.

    2018-05-01

    Auto-magnetizing (AutoMag) liners [Slutz et al., Phys. Plasmas 24, 012704 (2017)] are designed to generate up to 100 T of axial magnetic field in the fuel for Magnetized Liner Inertial Fusion [Slutz et al., Phys. Plasmas 17, 056303 (2010)] without the need for external field coils. AutoMag liners (cylindrical tubes) are composed of discrete metallic helical conduction paths separated by electrically insulating material. Initially, helical current in the AutoMag liner produces internal axial magnetic field during a long (100 to 300 ns) current prepulse with an average current rise rate d I / d t = 5 k A / n s . After the cold fuel is magnetized, a rapidly rising current ( 200 k A / n s ) generates a calculated electric field of 64 M V / m between the helices. Such field is sufficient to force dielectric breakdown of the insulating material after which liner current is reoriented from helical to predominantly axial which ceases the AutoMag axial magnetic field production mechanism and the z-pinch liner implodes. Proof of concept experiments have been executed on the Mykonos linear transformer driver to measure the axial field produced by a variety of AutoMag liners and to evaluate what physical processes drive dielectric breakdown. A range of field strengths have been generated in various cm-scale liners in agreement with magnetic transient simulations including a measured field above 90 T at I = 350 kA. By varying the helical pitch angle, insulator material, and insulator geometry, favorable liner designs have been identified for which breakdown occurs under predictable and reproducible field conditions.

  15. Application of human factors engineering (HFE) to the design of a naloxone auto-injector for the treatment of opioid emergencies.

    PubMed

    Raffa, Robert B; Taylor, Robert; Pergolizzi, Joseph V; Nalamachu, Srinivas; Edwards, Eric S; Edwards, Evan T

    2017-02-01

    The increased use of opioids for chronic treatment of pain and the resulting epidemic of opioid overdoses have created a major public health challenge. Parenteral naloxone has been used since the 1970's to treat opioid overdose. Recently, a novel naloxone auto-injector device (EVZIO, kaleo, Inc., Richmond, VA) was approved by the Food and Drug Administration. In this article, we review the Human Factors Engineering (HFE) process used in the development and testing of this novel naloxone auto-injector currently used in nonmedical settings for the emergency treatment of known or suspected opioid overdose. HFE methods were employed throughout the product development process for the naloxone auto-injector including formative and summative studies in order to optimize the auto-injector's user interface, mitigate use-related hazards and increase reliability during an opioid emergency use scenario. HFE was also used to optimize the product's design and user interface in order to reduce or prevent user confusion and misuse. The naloxone auto-injector went through a rigorous HFE process that included perceptual, cognitive, and physical action analysis; formative usability evaluations; use error analysis and summative design validation studies. Applying HFE resulted in the development of a product that is safe, fast, easy and predictably reliable to deliver a potentially life-saving dose of naloxone during an opioid overdose emergency. The naloxone auto-injector may be considered as a universal precaution option for at-risk patients prescribed opioids or those who are at increased risk for an opioid overdose emergency.

  16. Automotive Body Fillers; Auto Body Repair and Refinishing 2: 9035.03.

    ERIC Educational Resources Information Center

    Dade County Public Schools, Miami, FL.

    This course provides students with the general information, technical knowledge, basic skills, attitudes, and values required for job entry level as an auto body repair helper. Course content includes goals, specific objectives, orientation, filling with body solder, and plastic filler. A post-test sample is appended. (NH)

  17. The ZeroAccess Auto-Clicking and Search-Hijacking Click Fraud Modules

    DTIC Science & Technology

    2013-12-16

    payloads and instead began distributing Bitcoin miners and click fraud modules.3 From a technical perspective, the primary click fraud malware used in...this era operated in the indiscriminate “auto-clicking” fashion we describe in Section 5. Alongside the click fraud and Bitcoin payloads, ZeroAccess

  18. Sec. Chu Announces the First Auto Loans for Advanced Technologies

    ScienceCinema

    Secretary Chu

    2017-12-09

    Energy Secretary Steven Chu announced $8 billion in conditional loan commitments for the development of innovative, advanced vehicle technologies that will create thousands of green jobs while helping reduce the nation’s dangerous dependence on foreign oil. The first three auto loans for advanced technologies were awarded to Ford Motor Company, Nissan Motors and Tesla Motors.

  19. Sec. Chu Announces the First Auto Loans for Advanced Technologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Secretary Chu

    2009-07-16

    Energy Secretary Steven Chu announced $8 billion in conditional loan commitments for the development of innovative, advanced vehicle technologies that will create thousands of green jobs while helping reduce the nation’s dangerous dependence on foreign oil. The first three auto loans for advanced technologies were awarded to Ford Motor Company, Nissan Motors and Tesla Motors.

  20. Auto-programmable impulse neural circuits

    NASA Technical Reports Server (NTRS)

    Watula, D.; Meador, J.

    1990-01-01

    Impulse neural networks use pulse trains to communicate neuron activation levels. Impulse neural circuits emulate natural neurons at a more detailed level than that typically employed by contemporary neural network implementation methods. An impulse neural circuit which realizes short term memory dynamics is presented. The operation of that circuit is then characterized in terms of pulse frequency modulated signals. Both fixed and programmable synapse circuits for realizing long term memory are also described. The implementation of a simple and useful unsupervised learning law is then presented. The implementation of a differential Hebbian learning rule for a specific mean-frequency signal interpretation is shown to have a straightforward implementation using digital combinational logic with a variation of a previously developed programmable synapse circuit. This circuit is expected to be exploited for simple and straightforward implementation of future auto-adaptive neural circuits.

  1. Equipment for linking the AutoAnalyzer on-line to a computer

    PubMed Central

    Simpson, D.; Sims, G. E.; Harrison, M. I.; Whitby, L. G.

    1971-01-01

    An Elliott 903 computer with 8K central core store and magnetic tape backing store has been operated for approximately 20 months in a clinical chemistry laboratory. Details of the equipment designed for linking AutoAnalyzers on-line to the computer are described, and data presented concerning the time required by the computer for different processes. The reliability of the various components in daily operation is discussed. Limitations in the system's capabilities have been defined, and ways of overcoming these are delineated. At present, routine operations include the preparation of worksheets for a limited range of tests (five channels), monitoring of up to 11 AutoAnalyzer channels at a time on a seven-day week basis (with process control and automatic calculation of results), and the provision of quality control data. Cumulative reports can be printed out on those analyses for which computer-prepared worksheets are provided but the system will require extension before these can be issued sufficiently rapidly for routine use. PMID:5551384

  2. 3D printed auto-mixing chip enables rapid smartphone diagnosis of anemia

    PubMed Central

    Plevniak, Kimberly; Campbell, Matthew; Hodges, Abby; He, Mei

    2016-01-01

    Clinical diagnosis requiring central facilities and site visits can be burdensome for patients in resource-limited or rural areas. Therefore, development of a low-cost test that utilizes smartphone data collection and transmission would beneficially enable disease self-management and point-of-care (POC) diagnosis. In this paper, we introduce a low-cost iPOC3D diagnostic strategy which integrates 3D design and printing of microfluidic POC device with smartphone-based disease diagnosis in one process as a stand-alone system, offering strong adaptability for establishing diagnostic capacity in resource-limited areas and low-income countries. We employ smartphone output (AutoCAD 360 app) and readout (color-scale analytical app written in-house) functionalities for rapid 3D printing of microfluidic auto-mixers and colorimetric detection of blood hemoglobin levels. The auto-mixing of reagents with blood via capillary force has been demonstrated in 1 second without the requirement of external pumps. We employed this iPOC3D system for point-of-care diagnosis of anemia using a training set of patients (nanemia = 16 and nhealthy = 6), which showed consistent measurements of blood hemoglobin levels (a.u.c. = 0.97) and comparable diagnostic sensitivity and specificity, compared with standard clinical hematology analyzer. Capable of 3D fabrication flexibility and smartphone compatibility, this work presents a novel diagnostic strategy for advancing personalized medicine and mobile healthcare. PMID:27733894

  3. 3D printed auto-mixing chip enables rapid smartphone diagnosis of anemia.

    PubMed

    Plevniak, Kimberly; Campbell, Matthew; Myers, Timothy; Hodges, Abby; He, Mei

    2016-09-01

    Clinical diagnosis requiring central facilities and site visits can be burdensome for patients in resource-limited or rural areas. Therefore, development of a low-cost test that utilizes smartphone data collection and transmission would beneficially enable disease self-management and point-of-care (POC) diagnosis. In this paper, we introduce a low-cost i POC 3D diagnostic strategy which integrates 3D design and printing of microfluidic POC device with smartphone-based disease diagnosis in one process as a stand-alone system, offering strong adaptability for establishing diagnostic capacity in resource-limited areas and low-income countries. We employ smartphone output (AutoCAD 360 app) and readout (color-scale analytical app written in-house) functionalities for rapid 3D printing of microfluidic auto-mixers and colorimetric detection of blood hemoglobin levels. The auto-mixing of reagents with blood via capillary force has been demonstrated in 1 second without the requirement of external pumps. We employed this i POC 3D system for point-of-care diagnosis of anemia using a training set of patients (n anemia  = 16 and n healthy  = 6), which showed consistent measurements of blood hemoglobin levels (a.u.c. = 0.97) and comparable diagnostic sensitivity and specificity, compared with standard clinical hematology analyzer. Capable of 3D fabrication flexibility and smartphone compatibility, this work presents a novel diagnostic strategy for advancing personalized medicine and mobile healthcare.

  4. Resource-Efficient, Hierarchical Auto-Tuning of a Hybrid Lattice Boltzmann Computation on the Cray XT4

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Computational Research Division, Lawrence Berkeley National Laboratory; NERSC, Lawrence Berkeley National Laboratory; Computer Science Department, University of California, Berkeley

    2009-05-04

    We apply auto-tuning to a hybrid MPI-pthreads lattice Boltzmann computation running on the Cray XT4 at National Energy Research Scientific Computing Center (NERSC). Previous work showed that multicore-specific auto-tuning can improve the performance of lattice Boltzmann magnetohydrodynamics (LBMHD) by a factor of 4x when running on dual- and quad-core Opteron dual-socket SMPs. We extend these studies to the distributed memory arena via a hybrid MPI/pthreads implementation. In addition to conventional auto-tuning at the local SMP node, we tune at the message-passing level to determine the optimal aspect ratio as well as the correct balance between MPI tasks and threads permore » MPI task. Our study presents a detailed performance analysis when moving along an isocurve of constant hardware usage: fixed total memory, total cores, and total nodes. Overall, our work points to approaches for improving intra- and inter-node efficiency on large-scale multicore systems for demanding scientific applications.« less

  5. [Evaluation of selected endocrine complications in patients treated with auto- and allo-haematopoietic stem cell transplantation].

    PubMed

    Niedzielska, Ewa; Wójcik, Dorota; Barg, Ewa; Pietras, Wojciech; Sega-Pondel, Dorota; Doroszko, Adrian; Niedzielska, Małgorzata; Skarzyńska, Małgorzata; Chybicka, Alicja

    2008-01-01

    The aim of this study was to evaluate the endocrine complications, in particular disorders of growth and thyroid function and glucose metabolism dysfunctions in patients treated with allo- and auto-haematopoietic stem cell transplantation (HSCT). The investigated group consisted of: I. 16 patients after auto-HSCT (6 girls, 10 boys) aged 3-20 years (average 10,8+/-) because of acute myelogenous leukaemia (n=5), non Hodgkin lymphoma (n=3), neuroblastoma (n=3), embryonal cancer (n=2), medulloblastoma (n=1), Ewing's sarcoma/PNET (n=1), hyper eosinophilic syndrome (n=1). High dose chemiotherapy (HDC/T) included: BU/MEL (busulfan/melfalan) (n=7), BEAM (carmustine, eteposide, cytosine arabinose, melfalan) (n=3). II. 30 patients after allo-HSCT (20 girls, 10 boys) aged 3-17 years (average 9,56). Indication for HSCT was acute lymphoblastic leukaemia (n=11), acute myelogenous leukaemia (n=5), chronic myeloid leukaemia-CML (n=6), myelodysplastic syndromes (n=2), non Hodgkin lymphoma (n=1), juvenile myelomonocytic leukemia (n=1), severe aplastic anaemia (n=1), Blackfan-Diamond anaemia (n=1), severe combined immune deficiency (n=1), rhabdomyosarcoma (n=1). The patients underwent the following types of transplantation: HSCT of matched sibling donor (n=13), HSCT of matched unrelated donor (n=11) and HLA-mismatched related donor (n=6). The preparative regimens consisted of HDC/T usually BU/MEL (n=3); BU/CY/VP (busulfan, cyclophosphamide, etoposide) (6); BU/CY/ATG (anti-thymocyte globulin) (n=5), VP/ATG/TBI (total body irradiation) (n=3). 19 children received CI (cranial irradiation) prior to grafting: auto-HSCT (n=6) and allo-HSCT (n=13) and 6 patients underwent TBI. 18 children received high steroid doses at least 28 days before transplant, 4 patients in the auto-HSCT group, and in the allo-HSCT group 14 patients before and 20 after HSCT procedure. The analysis of thyroid-stimulating hormone (TSH), free triiodothyronine (fT3), free thyroxine (fT4), insulin-like growth factor 1

  6. A lack of association between hyperserotonemia and the increased frequency of serum anti-myelin basic protein auto-antibodies in autistic children

    PubMed Central

    2011-01-01

    Background One of the most consistent biological findings in autism is the elevated blood serotonin levels. Immune abnormalities, including autoimmunity with production of brain specific auto-antibodies, are also commonly observed in this disorder. Hyperserotonemia may be one of the contributing factors to autoimmunity in some patients with autism through the reduction of T-helper (Th) 1-type cytokines. We are the first to investigate the possible role of hyperserotonemia in the induction of autoimmunity, as indicated by serum anti-myelin-basic protein (anti-MBP) auto-antibodies, in autism. Methods Serum levels of serotonin and anti-MBP auto-antibodies were measured, by ELISA, in 50 autistic patients, aged between 5 and 12 years, and 30 healthy-matched children. Results Autistic children had significantly higher serum levels of serotonin and anti-MBP auto-antibodies than healthy children (P < 0.001 and P < 0.001, respectively). Increased serum levels of serotonin and anti-MBP auto-antibodies were found in 92% and 80%, respectively of autistic patients. Patients with severe autism had significantly higher serum serotonin levels than children with mild to moderate autism (P < 0.001). Serum serotonin levels had no significant correlations with serum levels of anti-MBP auto-antibodies in autistic patients (P = 0.39). Conclusions Hyperserotonemia may not be one of the contributing factors to the increased frequency of serum anti-MBP auto-antibodies in some autistic children. These data should be treated with caution until further investigations are performed. However, inclusion of serum serotonin levels as a correlate may be useful in other future immune studies in autism to help unravel the long-standing mystery of hyperserotonemia and its possible role in the pathophysiology of this disorder. PMID:21696608

  7. NMR binding and crystal structure reveal that intrinsically-unstructured regulatory domain auto-inhibits PAK4 by a mechanism different from that of PAK1.

    PubMed

    Wang, Wei; Lim, Liangzhong; Baskaran, Yohendran; Manser, Ed; Song, Jianxing

    2013-08-16

    Six human PAK members are classified into groups I (PAKs 1-3) and II (PAK4-6). Previously, only group I PAKs were thought to be auto-inhibited but very recently PAK4, the prototype of group II PAKs, has also been shown to be auto-inhibited by its N-terminal regulatory domain. However, the complete auto-inhibitory domain (AID) sequence remains undefined and the mechanism underlying its auto-inhibition is largely elusive. Here, the N-terminal regulatory domain of PAK4 sufficient for auto-inhibiting and binding Cdc42/Rac was characterized to be intrinsically unstructured, but nevertheless we identified the entire AID sequence by NMR. Strikingly, an AID peptide was derived by deleting the binding-unnecessary residues, which has a Kd of 320 nM to the PAK4 catalytic domain. Consequently, the PAK4 crystal structure complexed with the entire AID has been determined, which reveals that the complete kinase cleft is occupied by 20 AID residuescomposed of an N-terminal α-helix and a previously-identified pseudosubstrate motif, thus achieving auto-inhibition. Our study reveals that PAK4 is auto-inhibited by a novel mechanism which is completely different from that for PAK1, thus bearing critical implications for design of inhibitors specific for group II PAKs. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Auto Body Repair and Refinishing 2; Automotive Refinishing 1: 9035.04.

    ERIC Educational Resources Information Center

    Dade County Public Schools, Miami, FL.

    This course will provide the student with the general information, technical knowledge, basic skills, attitudes and values required for job entry as an auto body repair helper. Course content includes goals, specific objectives, orientation, service tools and bench skills, paint spray equipment, paint materials, and preparation of automobile body…

  9. Learning Activity Packets for Auto Mechanics II. Section A--Engine Rebuilding.

    ERIC Educational Resources Information Center

    Oklahoma State Board of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    Eight learning activity packets (LAPs) are provided for the instructional area of engine rebuilding in the auto mechanics II program. They accompany an instructor's guide available separately. The LAPs outline the study activities and performance tasks for these eight units: (1) engine condition evaluation; (2) engine removal; (3) engine…

  10. Crystal Structure of Human Dual-Specificity Tyrosine-Regulated Kinase 3 Reveals New Structural Features and Insights into its Auto-phosphorylation.

    PubMed

    Kim, Kuglae; Cha, Jeong Seok; Cho, Yong-Soon; Kim, Hoyoung; Chang, Nienping; Kim, Hye-Jung; Cho, Hyun-Soo

    2018-05-11

    Dual-specificity tyrosine-regulated kinases (DYRKs) auto-phosphorylate a critical tyrosine residue in their activation loop and phosphorylate their substrate on serine and threonine residues. The auto-phosphorylation occurs intramolecularly and is a one-off event. DYRK3 is selectively expressed at a high level in hematopoietic cells and attenuates erythroblast development, leading to anemia. In the present study, we determined the crystal structure of the mature form of human DYRK3 in complex with harmine, an ATP competitive inhibitor. The crystal structure revealed a phosphorylation site, residue S350, whose phosphorylation increases the stability of DYRK3 and enhances its kinase activity. In addition, our structural and biochemical assays suggest that the N-terminal auto-phosphorylation accessory domain stabilizes the DYRK3 protein, followed by auto-phosphorylation of the tyrosine of the activation loop, which is important for kinase activity. Finally, our docking analysis provides information for the design of novel and potent therapeutics to treat anemia. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. WE-G-BRD-07: Automated MR Image Standardization and Auto-Contouring Strategy for MRI-Based Adaptive Brachytherapy for Cervix Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saleh, H Al; Erickson, B; Paulson, E

    Purpose: MRI-based adaptive brachytherapy (ABT) is an emerging treatment modality for patients with gynecological tumors. However, MR image intensity non-uniformities (IINU) can vary from fraction to fraction, complicating image interpretation and auto-contouring accuracy. We demonstrate here an automated MR image standardization and auto-contouring strategy for MRI-based ABT of cervix cancer. Methods: MR image standardization consisted of: 1) IINU correction using the MNI N3 algorithm, 2) noise filtering using anisotropic diffusion, and 3) signal intensity normalization using the volumetric median. This post-processing chain was implemented as a series of custom Matlab and Java extensions in MIM (v6.4.5, MIM Software) and wasmore » applied to 3D T2 SPACE images of six patients undergoing MRI-based ABT at 3T. Coefficients of variation (CV=σ/µ) were calculated for both original and standardized images and compared using Mann-Whitney tests. Patient-specific cumulative MR atlases of bladder, rectum, and sigmoid contours were constructed throughout ABT, using original and standardized MR images from all previous ABT fractions. Auto-contouring was performed in MIM two ways: 1) best-match of one atlas image to the daily MR image, 2) multi-match of all previous fraction atlas images to the daily MR image. Dice’s Similarity Coefficients (DSCs) were calculated for auto-generated contours relative to reference contours for both original and standardized MR images and compared using Mann-Whitney tests. Results: Significant improvements in CV were detected following MR image standardization (p=0.0043), demonstrating an improvement in MR image uniformity. DSCs consistently increased for auto-contoured bladder, rectum, and sigmoid following MR image standardization, with the highest DSCs detected when the combination of MR image standardization and multi-match cumulative atlas-based auto-contouring was utilized. Conclusion: MR image standardization significantly improves

  12. [Comparison analysis of outcomes in primary light chain amyloidosis patients treated by auto peripheral blood stem cell transplantation or bortezomib plus dexamethasone].

    PubMed

    Zhao, Qian; Wang, Liping; Song, Ping; Li, Feng; Zhou, Xiaogang; Yu, Yaping; An, Zhiming; Wang, Xuli; Zhai, Yongping

    2016-04-01

    To explore the feature of primary light chain amyloidosis patients treated with high-dose melphalan with auto peripheral blood stem cell transplantation (auto-PBSCT) and bortezomib plus dexamethasone (VD). Thirty-eight patients diagnosed from September 2004 to September 2012 were analyzed retrospectively, including 15 cases received auto-PBSCT, 23 cases exposed with VD. The median follow-up duration for the patients was 34 months (range, 1-112 months), including auto-PBSCT group of 38 months (range, 5-112 months) and VD group of 31 months (range, 1-108 months). The organ response rate in all the patients was 39.5% (15/38), and the organ response rate between these two groups has no significant difference [33.3% (5/15) vs 43.5% (10/23), P=0.532]. However, the median time of organ response was significant difference [6 (3-10) months vs 3 (1-6) months, respectively (P=0.032)]. The 3-year overall survival (OS) rates in the two groups were 72.0% and 66.9%, and their average survival were 84.7 months and 75.9 months, respectively (P=0.683). In the patients with auto-PBSCT, the occurrence of III-IV grade of bone marrow suppression (P<0.001), fever (P<0.001), nausea and infection (P=0.006) were obviously higher than those with VD, but there was no statistically significant difference in pulmonary infection (P=0.069) and bloodstream infection (P=0.059). The preliminary results have presented that primary light chain amyloidosis patients treated with auto-PBSCT or VD had similar organ response rate and survival. However, more adverse events occurred in the group of auto-PBSCT.

  13. SU-E-J-208: Fast and Accurate Auto-Segmentation of Abdominal Organs at Risk for Online Adaptive Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gupta, V; Wang, Y; Romero, A

    2014-06-01

    Purpose: Various studies have demonstrated that online adaptive radiotherapy by real-time re-optimization of the treatment plan can improve organs-at-risk (OARs) sparing in the abdominal region. Its clinical implementation, however, requires fast and accurate auto-segmentation of OARs in CT scans acquired just before each treatment fraction. Autosegmentation is particularly challenging in the abdominal region due to the frequently observed large deformations. We present a clinical validation of a new auto-segmentation method that uses fully automated non-rigid registration for propagating abdominal OAR contours from planning to daily treatment CT scans. Methods: OARs were manually contoured by an expert panel to obtain groundmore » truth contours for repeat CT scans (3 per patient) of 10 patients. For the non-rigid alignment, we used a new non-rigid registration method that estimates the deformation field by optimizing local normalized correlation coefficient with smoothness regularization. This field was used to propagate planning contours to repeat CTs. To quantify the performance of the auto-segmentation, we compared the propagated and ground truth contours using two widely used metrics- Dice coefficient (Dc) and Hausdorff distance (Hd). The proposed method was benchmarked against translation and rigid alignment based auto-segmentation. Results: For all organs, the auto-segmentation performed better than the baseline (translation) with an average processing time of 15 s per fraction CT. The overall improvements ranged from 2% (heart) to 32% (pancreas) in Dc, and 27% (heart) to 62% (spinal cord) in Hd. For liver, kidneys, gall bladder, stomach, spinal cord and heart, Dc above 0.85 was achieved. Duodenum and pancreas were the most challenging organs with both showing relatively larger spreads and medians of 0.79 and 2.1 mm for Dc and Hd, respectively. Conclusion: Based on the achieved accuracy and computational time we conclude that the investigated auto

  14. Effect of polarization and focusing on laser pulse driven auto-resonant particle acceleration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sagar, Vikram; Sengupta, Sudip; Kaw, Predhiman

    2014-04-15

    The effect of laser polarization and focusing is theoretically studied on the final energy gain of a particle in the Auto-resonant acceleration scheme using a finite duration laser pulse with Gaussian shaped temporal envelope. The exact expressions for dynamical variables viz. position, momentum, and energy are obtained by analytically solving the relativistic equation of motion describing particle dynamics in the combined field of an elliptically polarized finite duration pulse and homogeneous static axial magnetic field. From the solutions, it is shown that for a given set of laser parameters viz. intensity and pulse length along with static magnetic field, themore » energy gain by a positively charged particle is maximum for a right circularly polarized laser pulse. Further, a new scheme is proposed for particle acceleration by subjecting it to the combined field of a focused finite duration laser pulse and static axial magnetic field. In this scheme, the particle is initially accelerated by the focused laser field, which drives the non-resonant particle to second stage of acceleration by cyclotron Auto-resonance. The new scheme is found to be efficient over two individual schemes, i.e., auto-resonant acceleration and direct acceleration by focused laser field, as significant particle acceleration can be achieved at one order lesser values of static axial magnetic field and laser intensity.« less

  15. Megagauss-level magnetic field production in cm-scale auto-magnetizing helical liners pulsed to 500 kA in 125 ns

    DOE PAGES

    Shipley, Gabriel A.; Awe, Thomas James; Hutsel, Brian Thomas; ...

    2018-05-03

    We present Auto-magnetizing (AutoMag) liners [Slutz et al., Phys. Plasmas 24, 012704 (2017)] are designed to generate up to 100 T of axial magnetic field in the fuel for Magnetized Liner Inertial Fusion [Slutz et al., Phys. Plasmas 17, 056303 (2010)] without the need for external field coils. AutoMag liners (cylindrical tubes) are composed of discrete metallic helical conduction paths separated by electrically insulating material. Initially, helical current in the AutoMag liner produces internal axial magnetic field during a long (100 to 300 ns) current prepulse with an average current rise rate dI/dt=5 kA/ns. After the cold fuel is magnetized,more » a rapidly rising current (200 kA/ns) generates a calculated electric field of 64 MV/m between the helices. Such field is sufficient to force dielectric breakdown of the insulating material after which liner current is reoriented from helical to predominantly axial which ceases the AutoMag axial magnetic field production mechanism and the z-pinch liner implodes. Proof of concept experiments have been executed on the Mykonos linear transformer driver to measure the axial field produced by a variety of AutoMag liners and to evaluate what physical processes drive dielectric breakdown. Lastly, a range of field strengths have been generated in various cm-scale liners in agreement with magnetic transient simulations including a measured field above 90 T at I = 350 kA. By varying the helical pitch angle, insulator material, and insulator geometry, favorable liner designs have been identified for which breakdown occurs under predictable and reproducible field conditions.« less

  16. Megagauss-level magnetic field production in cm-scale auto-magnetizing helical liners pulsed to 500 kA in 125 ns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shipley, Gabriel A.; Awe, Thomas James; Hutsel, Brian Thomas

    We present Auto-magnetizing (AutoMag) liners [Slutz et al., Phys. Plasmas 24, 012704 (2017)] are designed to generate up to 100 T of axial magnetic field in the fuel for Magnetized Liner Inertial Fusion [Slutz et al., Phys. Plasmas 17, 056303 (2010)] without the need for external field coils. AutoMag liners (cylindrical tubes) are composed of discrete metallic helical conduction paths separated by electrically insulating material. Initially, helical current in the AutoMag liner produces internal axial magnetic field during a long (100 to 300 ns) current prepulse with an average current rise rate dI/dt=5 kA/ns. After the cold fuel is magnetized,more » a rapidly rising current (200 kA/ns) generates a calculated electric field of 64 MV/m between the helices. Such field is sufficient to force dielectric breakdown of the insulating material after which liner current is reoriented from helical to predominantly axial which ceases the AutoMag axial magnetic field production mechanism and the z-pinch liner implodes. Proof of concept experiments have been executed on the Mykonos linear transformer driver to measure the axial field produced by a variety of AutoMag liners and to evaluate what physical processes drive dielectric breakdown. Lastly, a range of field strengths have been generated in various cm-scale liners in agreement with magnetic transient simulations including a measured field above 90 T at I = 350 kA. By varying the helical pitch angle, insulator material, and insulator geometry, favorable liner designs have been identified for which breakdown occurs under predictable and reproducible field conditions.« less

  17. A QR code identification technology in package auto-sorting system

    NASA Astrophysics Data System (ADS)

    di, Yi-Juan; Shi, Jian-Ping; Mao, Guo-Yong

    2017-07-01

    Traditional manual sorting operation is not suitable for the development of Chinese logistics. For better sorting packages, a QR code recognition technology is proposed to identify the QR code label on the packages in package auto-sorting system. The experimental results compared with other algorithms in literatures demonstrate that the proposed method is valid and its performance is superior to other algorithms.

  18. A simple protocol for attenuating the auto-fluorescence of cyanobacteria for optimized fluorescence in situ hybridization (FISH) imaging.

    PubMed

    Zeller, Perrine; Ploux, Olivier; Méjean, Annick

    2016-03-01

    Cyanobacteria contain pigments, which generate auto-fluorescence that interferes with fluorescence in situ hybridization (FISH) imaging of cyanobacteria. We describe simple chemical treatments using CuSO4 or H2O2 that significantly reduce the auto-fluorescence of Microcystis strains. These protocols were successfully applied in FISH experiments using 16S rRNA specific probes and filamentous cyanobacteria. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Auto and hetero-associative memory using a 2-D optical logic gate

    NASA Technical Reports Server (NTRS)

    Chao, Tien-Hsin (Inventor)

    1992-01-01

    An optical system for auto-associative and hetero-associative recall utilizing Hamming distance as the similarity measure between a binary input image vector V(sup k) and a binary image vector V(sup m) in a first memory array using an optical Exclusive-OR gate for multiplication of each of a plurality of different binary image vectors in memory by the input image vector. After integrating the light of each product V(sup k) x V(sup m), a shortest Hamming distance detection electronics module determines which product has the lowest light intensity and emits a signal that activates a light emitting diode to illuminate a corresponding image vector in a second memory array for display. That corresponding image vector is identical to the memory image vector V(sup m) in the first memory array for auto-associative recall or related to it, such as by name, for hetero-associative recall.

  20. Inductance analyzer based on auto-balanced circuit for precision measurement of fluxgate impedance

    NASA Astrophysics Data System (ADS)

    Setiadi, Rahmondia N.; Schilling, Meinhard

    2018-05-01

    An instrument for fluxgate sensor impedance measurement based on an auto-balanced circuit has been designed and characterized. The circuit design is adjusted to comply with the fluxgate sensor characteristics which are low impedance and highly saturable core with very high permeability. The system utilizes a NI-DAQ card and LabVIEW to process the signal acquisition and evaluation. Some fixed reference resistances are employed for system calibration using linear regression. A multimeter HP 34401A and impedance analyzer Agilent 4294A are used as calibrator and validator for the resistance and inductance measurements. Here, we realized a fluxgate analyzer instrument based on auto-balanced circuit, which measures the resistance and inductance of the device under test with a small error and much lower excitation current to avoid core saturation compared to the used calibrator.

  1. Learning Activity Packets for Auto Mechanics II. Section B--Electrical Systems.

    ERIC Educational Resources Information Center

    Oklahoma State Board of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    Six learning activity packets (LAPs) are provided for the instructional area of electrical systems in the auto mechanics II program. They accompany an instructor's guide available separately. The LAPs outline the study activities and performance tasks for these six units: (1) basic electrical theory, (2) battery service, (3) starting system, (4)…

  2. Prevention of Anaphylaxis: The Role of the Epinephrine Auto-Injector.

    PubMed

    Fromer, Leonard

    2016-12-01

    Anaphylaxis is a life-threatening condition, with at-risk individuals remaining at chronic high risk of recurrence. Anaphylaxis is frequently underrecognized and undertreated by healthcare providers. The first-line pharmacologic intervention for anaphylaxis is epinephrine, and guidelines uniformly agree that its prompt administration is vital to prevent progression, improve patient outcomes, and reduce hospitalizations and fatalities. Healthcare costs potentially associated with failure to provide epinephrine (hospitalizations and emergency department visits) generally exceed those of its provision. At-risk patients are prescribed epinephrine auto-injectors to facilitate timely administration in the event of an anaphylactic episode. Despite guideline recommendations that patients carry 2 auto-injectors at all times, a significant proportion of patients fail to do so, with cost of medicine cited as one reason for this lack of adherence. With the increase of high-deductible healthcare plans, patient adherence to recommendations may be further affected by increased cost sharing. The recognition and classification of epinephrine as a preventive medicine by both the US Preventive Services Task Force and insurers could increase patient access, improve outcomes, and save lives. Copyright © 2016 The Author. Published by Elsevier Inc. All rights reserved.

  3. Toward a 3D video format for auto-stereoscopic displays

    NASA Astrophysics Data System (ADS)

    Vetro, Anthony; Yea, Sehoon; Smolic, Aljoscha

    2008-08-01

    There has been increased momentum recently in the production of 3D content for cinema applications; for the most part, this has been limited to stereo content. There are also a variety of display technologies on the market that support 3DTV, each offering a different viewing experience and having different input requirements. More specifically, stereoscopic displays support stereo content and require glasses, while auto-stereoscopic displays avoid the need for glasses by rendering view-dependent stereo pairs for a multitude of viewing angles. To realize high quality auto-stereoscopic displays, multiple views of the video must either be provided as input to the display, or these views must be created locally at the display. The former approach has difficulties in that the production environment is typically limited to stereo, and transmission bandwidth for a large number of views is not likely to be available. This paper discusses an emerging 3D data format that enables the latter approach to be realized. A new framework for efficiently representing a 3D scene and enabling the reconstruction of an arbitrarily large number of views prior to rendering is introduced. Several design challenges are also highlighted through experimental results.

  4. Development of 40-in hybrid hologram screen for auto-stereoscopic video display

    NASA Astrophysics Data System (ADS)

    Song, Hyun Ho; Nakashima, Y.; Momonoi, Y.; Honda, Toshio

    2004-06-01

    Usually in auto stereoscopic display, there are two problems. The first problem is that large image display is difficult, and the second problem is that the view zone (which means the zone in which both eyes are put for stereoscopic or 3-D image observation) is very narrow. We have been developing an auto stereoscopic large video display system (over 100 inches diagonal) which a few people can view simultaneously1,2. Usually in displays that are over 100 inches diagonal, an optical video projection system is used. As one of auto stereoscopic display systems the hologram screen has been proposed3,4,5,6. However, if the hologram screen becomes too large, the view zone (corresponding to the reconstructed diffused object) causes color dispersion and color aberration7. We also proposed the additional Fresnel lens attached to the hologram screen. We call the screen a "hybrid hologram screen", (HHS in short). We made the HHS 866mm(H)×433mm(V) (about 40 inch diagonal)8,9,10,11. By using the lens in the reconstruction step, the angle between object light and reference light can be small, compared to without the lens. So, the spread of the view zone by the color dispersion and color aberration becomes small. And also, the virtual image which is reconstructed from the hologram screen can be transformed to a real image (view zone). So, it is not necessary to use a large lens or concave mirror while making a large hologram screen.

  5. Certain (-)-epigallocatechin-3-gallate (EGCG) auto-oxidation products (EAOPs) retain the cytotoxic activities of EGCG.

    PubMed

    Wei, Yaqing; Chen, Pingping; Ling, Tiejun; Wang, Yijun; Dong, Ruixia; Zhang, Chen; Zhang, Longjie; Han, Manman; Wang, Dongxu; Wan, Xiaochun; Zhang, Jinsong

    2016-08-01

    (-)-Epigallocatechin-3-gallate (EGCG) from green tea has anti-cancer effect. The cytotoxic actions of EGCG are associated with its auto-oxidation, leading to the production of hydrogen peroxide and formation of numerous EGCG auto-oxidation products (EAOPs), the structures and bioactivities of them remain largely unclear. In the present study, we compared several fundamental properties of EGCG and EAOPs, which were prepared using 5mg/mL EGCG dissolved in 200mM phosphate buffered saline (pH 8.0 at 37°C) and normal oxygen partial pressure for different periods of time. Despite the complete disappearance of EGCG after the 4-h auto-oxidation, 4-h EAOPs gained an enhanced capacity to deplete cysteine thiol groups, and retained the cytotoxic effects of EGCG as well as the capacity to produce hydrogen peroxide and inhibit thioredoxin reductase, a putative target for cancer prevention and treatment. The results indicate that certain EAOPs possess equivalent cytotoxic activities to EGCG, while exhibiting simultaneously enhanced capacity for cysteine depletion. These results imply that EGCG and EAOPs formed extracellularly function in concert to exhibit cytotoxic effects, which previously have been ascribed to EGCG alone. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Automatic Transmissions and Transaxles. Auto Mechanics Curriculum Guide. Module 8. Instructor's Guide.

    ERIC Educational Resources Information Center

    Hevel, David; Tannehill, Dana, Ed.

    This module is the eighth of nine modules in the competency-based Missouri Auto Mechanics Curriculum Guide. Six units cover: introduction to automatic transmission/transaxle; hydraulic control systems; transmission/transaxle diagnosis; automatic transmission/transaxle maintenance and adjustment; in-vehicle transmission repair; and off-car…

  7. Brillouin Scattering Spectrum Analysis Based on Auto-Regressive Spectral Estimation

    NASA Astrophysics Data System (ADS)

    Huang, Mengyun; Li, Wei; Liu, Zhangyun; Cheng, Linghao; Guan, Bai-Ou

    2018-06-01

    Auto-regressive (AR) spectral estimation technology is proposed to analyze the Brillouin scattering spectrum in Brillouin optical time-domain refelectometry. It shows that AR based method can reliably estimate the Brillouin frequency shift with an accuracy much better than fast Fourier transform (FFT) based methods provided the data length is not too short. It enables about 3 times improvement over FFT at a moderate spatial resolution.

  8. Recurrent polymorphic mating type variation in Madagascan Bulbophyllum species (Orchidaceae) exemplifies a high incidence of auto-pollination in tropical orchids

    PubMed Central

    Gamisch, Alexander; Fischer, Gunter A; Comes, Hans Peter

    2014-01-01

    The transition from outcrossing to self-fertilization is one of the most common evolutionary changes in angiosperms. The orchid family exemplifies this evolutionary trend but, because of a general lack of large-scale surveys on auto-pollination in orchid taxa, the incidence and modes of auto-pollination among (sub)tropical orchids remain poorly known. In the present study, we assessed the frequency and mode of auto-pollination within and among species of a largely monophyletic group of Madagascan Bulbophyllum. The capacity for autonomous fruit set was investigated by bagging experiments in the greenhouse and the field, complemented with detailed floral micromorphological studies of the gynostemium. Our survey comprises 393 accessions, representing at least 78 species, and thus approximately 37% of the species diversity of the genus in the Madagascan region. Our studies revealed that mating type is directly related to gynostemium structure, most often involving the presence or absence of a physical barrier termed ‘rostellum’. As a novel and unexpected finding, we identified eight species of a single lineage of Madagascan Bulbophyllum (termed ‘clade C’), in which auto-pollinating morphs (selfers), either lacking a rostellum or (rarely) possessing a stigmatic rostellum, co-exist with their pollinator-dependent conspecifics (outcrossers). We hypothesize that auto-pollination via rostellum abortion has a simple genetic basis, and probably evolved rapidly and recurrently by subtle changes in the timing of rostellum development (heterochrony). Thus, species of clade C may have an intrinsic genetic and developmental lability toward auto-pollination, allowing rapid evolutionary response under environmental, perhaps human-disturbed conditions favouring reproductive assurance. Overall, these findings should stimulate further research on the incidence, evolution, and maintenance of mating type variation in tropical orchids, as well as how they adapt(ed) to changing

  9. Determinants of isocyanate exposures in auto body repair and refinishing shops.

    PubMed

    Woskie, S R; Sparer, J; Gore, R J; Stowe, M; Bello, D; Liu, Y; Youngs, F; Redlich, C; Eisen, E; Cullen, M

    2004-07-01

    As part of the Survey of Painters and Repairers of Auto bodies by Yale (SPRAY), the determinants of isocyanate exposure in auto body repair shops were evaluated. Measurements (n = 380) of hexamethylene diisocyanate-based monomer and polyisocyanate and isophorone diisocyanate-based polyisocyanate were collected from 33 auto body shops. The median total reactive isocyanate concentrations expressed as mass concentration of the NCO functional group were: 206 microg NCO/m3 for spray operations; 0.93 microg NCO/m3 for samples collected in the vicinity of spray operations done on the shop floor (near spray); 0.05 microg NCO/m3 for office or other shop areas adjacent to spray areas (workplace background); 0.17 microg NCO/m3 for paint mixing and gun cleaning operations (mixing); 0.27 microg NCO/m3 for sanding operations. Exposure determinants for the sample NCO mass load were identified using linear regression, tobit regression and logistic regression models. For spray samples in a spray booth the significant determinants were the number of milliliters of NCO applied, the gallons of clear coat used by the shop each month and the type of spray booth used (custom built crossdraft, prefabricated crossdraft or downdraft/semi-downdraft). For near spray (bystander) samples, outdoor temperature >65 degrees F (18 degrees C) and shop size >5000 feet2 (465 m2) were significant determinants of exposure levels. For workplace background samples the shop annual income was the most important determinant. For sanding samples, the shop annual income and outdoor temperature >65 degrees F (18 degrees C) were the most significant determinants. Identification of these key exposure determinants will be useful in targeting exposure evaluation and control efforts to reduce isocyanate exposures.

  10. Auto Body. Instructional System Development Model for Vermont Area Vocational Centers.

    ERIC Educational Resources Information Center

    1975

    The model curriculum guide was developed to teach auto body repair in secondary schools in Vermont. From a needs assessment of the occupational opportunities in automotive services in the state, a group of selected occupations were analyzed for skill content and translated into the curriculum content. The guide consists of 14 units, each with a…

  11. Bilingual Skills Training Program. Auto Mechanics. Module 2.0: Ignition System.

    ERIC Educational Resources Information Center

    Northern New Mexico Community Coll., El Rito.

    This module on ignition systems is the second of six (CE 028 296-301) in the auto mechanics course of a bilingual skills training program. (A Vocabulary Development Workbook is available as CE 028 294.) The course is designed to furnish theoretical and laboratory experience. Module objectives are for students to develop trade-related…

  12. SU-C-BRB-05: Determining the Adequacy of Auto-Contouring Via Probabilistic Assessment of Ensuing Treatment Plan Metrics in Comparison with Manual Contours

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nourzadeh, H; Watkins, W; Siebers, J

    Purpose: To determine if auto-contour and manual-contour—based plans differ when evaluated with respect to probabilistic coverage metrics and biological model endpoints for prostate IMRT. Methods: Manual and auto-contours were created for 149 CT image sets acquired from 16 unique prostate patients. A single physician manually contoured all images. Auto-contouring was completed utilizing Pinnacle’s Smart Probabilistic Image Contouring Engine (SPICE). For each CT, three different 78 Gy/39 fraction 7-beam IMRT plans are created; PD with drawn ROIs, PAS with auto-contoured ROIs, and PM with auto-contoured OARs with the manually drawn target. For each plan, 1000 virtual treatment simulations with different sampledmore » systematic errors for each simulation and a different sampled random error for each fraction were performed using our in-house GPU-accelerated robustness analyzer tool which reports the statistical probability of achieving dose-volume metrics, NTCP, TCP, and the probability of achieving the optimization criteria for both auto-contoured (AS) and manually drawn (D) ROIs. Metrics are reported for all possible cross-evaluation pairs of ROI types (AS,D) and planning scenarios (PD,PAS,PM). Bhattacharyya coefficient (BC) is calculated to measure the PDF similarities for the dose-volume metric, NTCP, TCP, and objectives with respect to the manually drawn contour evaluated on base plan (D-PD). Results: We observe high BC values (BC≥0.94) for all OAR objectives. BC values of max dose objective on CTV also signify high resemblance (BC≥0.93) between the distributions. On the other hand, BC values for CTV’s D95 and Dmin objectives are small for AS-PM, AS-PD. NTCP distributions are similar across all evaluation pairs, while TCP distributions of AS-PM, AS-PD sustain variations up to %6 compared to other evaluated pairs. Conclusion: No significant probabilistic differences are observed in the metrics when auto-contoured OARs are used. The prostate auto

  13. Aggregate Auto Travel Forecasting : State of the Art and Suggestions for Future Research

    DOT National Transportation Integrated Search

    1976-12-01

    The report reviews existing forecasting models of auto vehicle miles of travel (VMT), and presents evidence that such models incorrectly omit time cost and spatial form variables. The omission of these variables biases parameter estimates in existing...

  14. Portable exhausters POR-004 SKID B, POR-005 SKID C, POR-006 SKID D storage plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, O.D.

    1997-09-04

    This document provides a storage plan for portable exhausters POR-004 SKID B, POR-005 SKID C, AND POR-006 SKID D. The exhausters will be stored until they are needed by the TWRS (Tank Waste Remediation Systems) Saltwell Pumping Program. The storage plan provides criteria for portable exhauster storage, periodic inspections during storage, and retrieval from storage.

  15. A comparison of profilometer and AutoCAD software techniques in evaluation of implant angulation in vitro.

    PubMed

    Assunção, Wirley Gonçalves; Gomes, Erica Alves; Tabata, Lucas Fernando; Gennari-Filho, Humberto

    2008-01-01

    The aim of this study was to compare 2 different methods of assessment of implants at different inclinations (90 degrees and 65 degrees)--with a profilometer and AutoCAD software. Impressions (n = 5) of a metal matrix containing 2 implants, 1 at 90 degrees to the surface and 1 at 65 degrees to the surface, were obtained with square impression copings joined together with dental floss splinting covered with autopolymerizing acrylic resin, an open custom tray, and vinyl polysiloxane impression material. Measurement of the angles (in degrees) of the implant analogs were assessed by the same blinded operator with a profilometer and through analysis of digitized images by AutoCAD software. For each implant analog, 3 readings were performed with each method. The results were subjected to a nonparametric Kruskal-Wallis test, with P < or = .05 considered significant. For implants perpendicular to the horizontal surface of the specimen (90 degrees), there were no significant differences between the mean measurements obtained with the profilometer (90.04 degrees) and AutoCAD (89.95 degrees; P = .9142). In the analyses of the angled implants at 65 degrees in relation to the horizontal surface of the specimen, significant differences were observed (P = .0472) between the mean readings with the profilometer (65.73 degrees) and AutoCAD (66.25 degrees). The degrees of accuracy of implant angulation recording vary among the techniques available and may vary depending on the angle of the implant. Further investigation is needed to determine the best test conditions and the best measuring technique for determination of the angle of the implant in vitro.

  16. An auto-adaptive optimization approach for targeting nonpoint source pollution control practices.

    PubMed

    Chen, Lei; Wei, Guoyuan; Shen, Zhenyao

    2015-10-21

    To solve computationally intensive and technically complex control of nonpoint source pollution, the traditional genetic algorithm was modified into an auto-adaptive pattern, and a new framework was proposed by integrating this new algorithm with a watershed model and an economic module. Although conceptually simple and comprehensive, the proposed algorithm would search automatically for those Pareto-optimality solutions without a complex calibration of optimization parameters. The model was applied in a case study in a typical watershed of the Three Gorges Reservoir area, China. The results indicated that the evolutionary process of optimization was improved due to the incorporation of auto-adaptive parameters. In addition, the proposed algorithm outperformed the state-of-the-art existing algorithms in terms of convergence ability and computational efficiency. At the same cost level, solutions with greater pollutant reductions could be identified. From a scientific viewpoint, the proposed algorithm could be extended to other watersheds to provide cost-effective configurations of BMPs.

  17. A fuzzy feature fusion method for auto-segmentation of gliomas with multi-modality diffusion and perfusion magnetic resonance images in radiotherapy.

    PubMed

    Guo, Lu; Wang, Ping; Sun, Ranran; Yang, Chengwen; Zhang, Ning; Guo, Yu; Feng, Yuanming

    2018-02-19

    The diffusion and perfusion magnetic resonance (MR) images can provide functional information about tumour and enable more sensitive detection of the tumour extent. We aimed to develop a fuzzy feature fusion method for auto-segmentation of gliomas in radiotherapy planning using multi-parametric functional MR images including apparent diffusion coefficient (ADC), fractional anisotropy (FA) and relative cerebral blood volume (rCBV). For each functional modality, one histogram-based fuzzy model was created to transform image volume into a fuzzy feature space. Based on the fuzzy fusion result of the three fuzzy feature spaces, regions with high possibility belonging to tumour were generated automatically. The auto-segmentations of tumour in structural MR images were added in final auto-segmented gross tumour volume (GTV). For evaluation, one radiation oncologist delineated GTVs for nine patients with all modalities. Comparisons between manually delineated and auto-segmented GTVs showed that, the mean volume difference was 8.69% (±5.62%); the mean Dice's similarity coefficient (DSC) was 0.88 (±0.02); the mean sensitivity and specificity of auto-segmentation was 0.87 (±0.04) and 0.98 (±0.01) respectively. High accuracy and efficiency can be achieved with the new method, which shows potential of utilizing functional multi-parametric MR images for target definition in precision radiation treatment planning for patients with gliomas.

  18. Auto Mechanics I. Learning Activity Packets (LAPs). Section A--Orientation and Safety.

    ERIC Educational Resources Information Center

    Oklahoma State Board of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This document contains seven learning activity packets (LAPs) that outline the study activities for the orientation and safety instructional area for an Auto Mechanics I course. The seven LAPs cover the following topics: orientation, safety, hand tools, arc welding, oxyacetylene cutting, oxyacetylene fusion welding, and oxyacetylene braze welding.…

  19. Steering and Suspension Systems. Auto Mechanics Curriculum Guide. Module 5. Instructor's Guide.

    ERIC Educational Resources Information Center

    Rains, Larry

    This module is the fifth of nine modules in the competency-based Missouri Auto Mechanics Curriculum Guide. Seventeen units cover: steering system design; diagnosing steering systems problems; inspecting and replacing steering linkage components; manual and power steering gear service; manual and power rack and pinion steering gear service; power…

  20. Evaluation of the auto-refraction function of the Nidek OPD-Scan III.

    PubMed

    McGinnigle, Samantha; Naroo, Shehzad A; Eperjesi, Frank

    2014-03-01

    The aim was to evaluate the validity and repeatability of the auto-refraction function of the Nidek OPD-Scan III (Nidek Technologies, Gamagori, Japan) compared with non-cycloplegic subjective refraction. The Nidek OPD-Scan III is a new aberrometer/corneal topographer workstation based on the skiascopy principle. It combines a wavefront aberrometer, topographer, autorefractor, auto keratometer and pupillometer/pupillographer. Objective refraction results obtained using the Nidek OPD-Scan III were compared with non-cycloplegic subjective refraction for 108 eyes of 54 participants (29 female) with a mean age of 23.7 ± 9.5 years. Intra-session and inter-session variability were assessed on 14 subjects (28 eyes). The Nidek OPD-Scan III gave slightly more negative readings than results obtained by subjective refraction (Nidek mean difference -0.19 ± 0.36 DS, p < 0.01 for sphere; -0.19 ± 0.35 DS, p < 0.01 for mean spherical equivalent; -0.002 ± 0.23 DC, p = 0.91 for cylinder; -0.06 ± 0.38 DC, p = 0.30 for J0 and -0.36 ± 0.31 DC for J45, p = 0.29). Auto-refractor results for 74 per cent of spherical readings and 60 per cent of cylindrical powers were within ± 0.25 of subjective refraction. There was high intra-session and inter-session repeatability for all parameters; 90 per cent of inter-session repeatability results were within 0.25 D. The Nidek OPD-Scan III gives valid and repeatable measures of objective refraction when compared with non-cycloplegic subjective refraction. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  1. Deep Drilling and Sampling via the Wireline Auto-Gopher Driven by Piezoelectric Percussive Actuator and EM Rotary Motor

    NASA Technical Reports Server (NTRS)

    Bar-Cohen, Yoseph; Badescu, Mircea; Sherrit, Stewart; Zacny, Kris; Paulsen, Gale L; Beegle, Luther; Bao, Xiaoqi

    2012-01-01

    The ability to penetrate subsurfaces and perform sample acquisition at depths of meters is critical for future NASA in-situ exploration missions to bodies in the solar system, including Mars and Europa. A corer/sampler was developed with the goal of acquiring pristine samples by reaching depths on Mars beyond the oxidized and sterilized zone. To developed rotary-hammering coring drill, called Auto-Gopher, employs a piezoelectric actuated percussive mechanism for breaking formations and an electric motor rotates the bit to remove the powdered cuttings. This sampler is a wireline mechanism that is incorporated with an inchworm mechanism allowing thru cyclic coring and core removal to reach great depths. The penetration rate is being optimized by simultaneously activating the percussive and rotary motions of the Auto-Gopher. The percussive mechanism is based on the Ultrasonic/Sonic Drill/Corer (USDC) mechanism that is driven by piezoelectric stack and that was demonstrated to require low axial preload. The Auto-Gopher has been produced taking into account the a lessons learned from the development of the Ultrasonic/Sonic Gopher that was designed as a percussive ice drill and was demonstrated in Antarctica in 2005 to reach about 2 meters deep. A field demonstration of the Auto-Gopher is currently being planned with objective of reaching as deep as 3 to 5 meters in tufa subsurface.

  2. Development of the auto-steering software and equipment technology (ASSET)

    NASA Astrophysics Data System (ADS)

    McKay, Mark D.; Anderson, Matthew O.; Wadsworth, Derek C.

    2003-09-01

    The Idaho National Engineering and Environmental Laboratory (INEEL), through collaboration with INSAT Co., has developed a low cost robotic auto-steering system for parallel contour swathing. The capability to perform parallel contour swathing while minimizing "skip" and "overlap" is a necessity for cost-effective crop management within precision agriculture. Current methods for performing parallel contour swathing consist of using a Differential Global Position System (DGPS) coupled with a light bar system to prompt an operator where to steer. The complexity of operating heavy equipment, ensuring proper chemical mixture and application, and steering to a light bar indicator can be overwhelming to an operator. To simplify these tasks, an inexpensive robotic steering system has been developed and tested on several farming implements. This development leveraged research conducted by the INEEL and Utah State University. The INEEL-INSAT Auto-Steering Software and Equipment Technology provides the following: 1) the ability to drive in a straight line within +/- 2 feet while traveling at least 15 mph, 2) interfaces to a Real Time Kinematic (RTK) DGPS and sub-meter DGPS, 3) safety features such as Emergency-stop, steering wheel deactivation, computer watchdog deactivation, etc., and 4) a low-cost, field-ready system that is easily adapted to other systems.

  3. PKA, novel PKC isoforms, and ERK is mediating PACAP auto-regulation via PAC1R in human neuroblastoma NB-1 cells.

    PubMed

    Georg, Birgitte; Falktoft, Birgitte; Fahrenkrug, Jan

    2016-12-01

    The neuropeptide PACAP is expressed throughout the central and peripheral nervous system where it modulates diverse physiological functions including neuropeptide gene expression. We here report that in human neuroblastoma NB-1 cells PACAP transiently induces its own expression. Maximal PACAP mRNA expression was found after stimulation with PACAP for 3h. PACAP auto-regulation was found to be mediated by activation of PACAP specific PAC 1 Rs as PACAP had >100-fold higher efficacy than VIP, and the PAC 1 R selective agonist Maxadilan potently induced PACAP gene expression. Experiments with pharmacological kinase inhibitors revealed that both PKA and novel but not conventional PKC isozymes were involved in the PACAP auto-regulation. Inhibition of MAPK/ERK kinase (MEK) also impeded the induction, and we found that PKA, novel PKC and ERK acted in parallel and were thus not part of the same pathways. The expression of the transcription factor EGR1 previously ascribed as target of PACAP signalling was found to be transiently induced by PACAP and pharmacological inhibition of either PKC or MEK1/2 abolished PACAP mediated EGR1 induction. In contrast, inhibition of PKA mediated increased PACAP mediated EGR1 induction. Experiments using siRNA against EGR1 to lower the expression did however not affect the PACAP auto-regulation indicating that this immediate early gene product is not part of PACAP auto-regulation in NB-1 cells. We here reveal that in NB-1 neuroblastoma cells, PACAP induces its own expression by activation of PAC 1 R, and that the signalling is different from the PAC 1 R signalling mediating induction of VIP in the same cells. PACAP auto-regulation depends on parallel activation of PKA, novel PKC isoforms, and ERK, while EGR1 does not seem to be part of the PACAP auto-regulation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Lived Experience as Pedagogical Resource: Towards an Auto-Ethnographic Pedagogy of Writing

    ERIC Educational Resources Information Center

    Voorhees, T.

    2016-01-01

    The key element of auto-ethnography, as distinct from memoir and autobiography, is the positioning of the writer within the social, cultural, economic, and political framework of what is being observed. T. Voorhees saw immense value in this positioning for students today, especially newer college students who understand their relationship to…

  5. Privacy Act System of Records: Office of the Inspector General AutoAudit, EPA-50

    EPA Pesticide Factsheets

    Learn more about the Office of the Inspector General AutoAudit System, including who is covered in the system, the purpose of data collection, routine uses for the system's records, and other security procedures.

  6. Multi-Level and Multi-Scale Feature Aggregation Using Pretrained Convolutional Neural Networks for Music Auto-Tagging

    NASA Astrophysics Data System (ADS)

    Lee, Jongpil; Nam, Juhan

    2017-08-01

    Music auto-tagging is often handled in a similar manner to image classification by regarding the 2D audio spectrogram as image data. However, music auto-tagging is distinguished from image classification in that the tags are highly diverse and have different levels of abstractions. Considering this issue, we propose a convolutional neural networks (CNN)-based architecture that embraces multi-level and multi-scaled features. The architecture is trained in three steps. First, we conduct supervised feature learning to capture local audio features using a set of CNNs with different input sizes. Second, we extract audio features from each layer of the pre-trained convolutional networks separately and aggregate them altogether given a long audio clip. Finally, we put them into fully-connected networks and make final predictions of the tags. Our experiments show that using the combination of multi-level and multi-scale features is highly effective in music auto-tagging and the proposed method outperforms previous state-of-the-arts on the MagnaTagATune dataset and the Million Song Dataset. We further show that the proposed architecture is useful in transfer learning.

  7. AUTO_DERIV: Tool for automatic differentiation of a Fortran code

    NASA Astrophysics Data System (ADS)

    Stamatiadis, S.; Farantos, S. C.

    2010-10-01

    AUTO_DERIV is a module comprised of a set of FORTRAN 95 procedures which can be used to calculate the first and second partial derivatives (mixed or not) of any continuous function with many independent variables. The mathematical function should be expressed as one or more FORTRAN 77/90/95 procedures. A new type of variables is defined and the overloading mechanism of functions and operators provided by the FORTRAN 95 language is extensively used to define the differentiation rules. Proper (standard complying) handling of floating-point exceptions is provided by using the IEEE_EXCEPTIONS intrinsic module (Technical Report 15580, incorporated in FORTRAN 2003). New version program summaryProgram title: AUTO_DERIV Catalogue identifier: ADLS_v2_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADLS_v2_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 2963 No. of bytes in distributed program, including test data, etc.: 10 314 Distribution format: tar.gz Programming language: Fortran 95 + (optionally) TR-15580 (Floating-point exception handling) Computer: all platforms with a Fortran 95 compiler Operating system: Linux, Windows, MacOS Classification: 4.12, 6.2 Catalogue identifier of previous version: ADLS_v1_0 Journal reference of previous version: Comput. Phys. Comm. 127 (2000) 343 Does the new version supersede the previous version?: Yes Nature of problem: The need to calculate accurate derivatives of a multivariate function frequently arises in computational physics and chemistry. The most versatile approach to evaluate them by a computer, automatically and to machine precision, is via user-defined types and operator overloading. AUTO_DERIV is a Fortran 95 implementation of them, designed to evaluate the first and second derivatives of a function of many variables

  8. Educating for Vocational Excellence: The Auto/Biographical Exploration of Enacted Craft Pedagogy

    ERIC Educational Resources Information Center

    Tyson, Ruhi

    2015-01-01

    The focus of this article is on education for vocational excellence (the combination of virtue and good judgment or phronesis/practical wisdom) through an examination of episodes from the auto/biographical study of master craftsman Wolfgang B. Vocational excellence is an issue sometimes discussed with regard to teacher training for schools and…

  9. Heating and Air Conditioning. Auto Mechanics Curriculum Guide Module 9. Instructor's Guide.

    ERIC Educational Resources Information Center

    Hevel, David

    This unit of instruction is one of a series of modules in the Missouri Auto Mechanics Curriculum Guide. The module's format was developed for competency-based teaching and testing. The module contains 11 units, each of which contains the following components: a competency profile, objective sheets, references, notes to the instructor, lesson…

  10. Comparison of auto-fluorescence and tetracycline fluorescence for guided bone surgery of medication-related osteonecrosis of the jaw: a randomized controlled feasibility study.

    PubMed

    Ristow, O; Otto, S; Geiß, C; Kehl, V; Berger, M; Troeltzsch, M; Koerdt, S; Hohlweg-Majert, B; Freudlsperger, C; Pautke, C

    2017-02-01

    Recent studies have indicated that bone shows auto-fluorescence under an appropriate fluorescence lamp. The aim of this preliminary study was to compare the success rates of the established tetracycline fluorescence-guided bone surgery with auto-fluorescence-guided bone surgery in the treatment of medication-related osteonecrosis of the jaw (MRONJ). Forty patients suffering from MRONJ were referred for surgical treatment and were divided randomly into two groups: auto-fluorescence (n=20) or tetracycline fluorescence (n=20) guided bone surgery. The primary endpoint was treatment success, defined as the absence of exposed bone at 8 weeks after surgery. Secondary outcomes assessed were mucosal integrity, signs of infection, pain, and loss of sensitivity; these were evaluated descriptively at 10 days, 8 weeks, 6 months, and 1 year after surgery. At 8 weeks postoperative, 18/20 patients (90%) in the auto-fluorescence group and 17/20 patients (85%) in the tetracycline fluorescence group showed mucosal integrity (P>0.05). At the last follow-up, 94% in the auto-fluorescence group and 89% in the tetracycline fluorescence group presented complete mucosal coverage with no exposed bone, infection, or pain (P>0.05). There was no significant difference between the two techniques for any of the secondary outcomes (P>0.05). The results of this preliminary study show that auto-fluorescence-guided bone surgery has comparable success rates to the established tetracycline fluorescence-guided bone surgery. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. The simulation of emergent dispatch of cars for intelligent driving autos

    NASA Astrophysics Data System (ADS)

    Zheng, Ziao

    2018-03-01

    It is widely acknowledged that it is important for the development of intelligent cars to be widely accepted by the majority of car users. While most of the intelligent cars have the system of monitoring itself whether it is on the good situation to drive, it is also clear that studies should be performed on the way of cars for the emergent rescue of the intelligent vehicles. In this study, writer focus mainly on how to derive a separate system for the car caring teams to arrive as soon as they get the signal sent out by the intelligent driving autos. This simulation measure the time for the rescuing team to arrive, the cost it spent on arriving on the site of car problem happens, also how long the queue is when the rescuing auto is waiting to cross a road. This can be definitely in great use when there are a team of intelligent cars with one car immediately having problems causing it's not moving and can be helpful in other situations. Through this way, the interconnection of cars can be a safety net for the drivers encountering difficulties in any time.

  12. Preparation of pentacene thin film deposited using organic material auto-feeding system for the fabrication of organic thin film transistor.

    PubMed

    Kim, Young Baek; Choi, Bum Ho; Lim, Yong Hwan; Yoo, Ha Na; Lee, Jong Ho; Kim, Jin Hyeok

    2011-02-01

    In this study, pentacene organic thin film was prepared using newly developed organic material auto-feeding system integrated with linear cell and characterized. The newly developed organic material auto-feeding system consists of 4 major parts: reservoir, micro auto-feeder, vaporizer, and linear cell. The deposition of organic thin film could be precisely controlled by adjusting feeding rate, main tube size, position and size of nozzle. 10 nm thick pentacene thin film prepared on glass substrate exhibited high uniformity of 3.46% which is higher than that of conventional evaporation method using point cell. The continuous deposition without replenishment of organic material can be performed over 144 hours with regulated deposition control. The grain size of pentacene film which affect to mobility of OTFT, was controlled as a function of the temperature.

  13. Aviation obstacle auto-extraction using remote sensing information

    NASA Astrophysics Data System (ADS)

    Zimmer, N.; Lugsch, W.; Ravenscroft, D.; Schiefele, J.

    2008-10-01

    An Obstacle, in the aviation context, may be any natural, man-made, fixed or movable object, permanent or temporary. Currently, the most common way to detect relevant aviation obstacles from an aircraft or helicopter for navigation purposes and collision avoidance is the use of merged infrared and synthetic information of obstacle data. Several algorithms have been established to utilize synthetic and infrared images to generate obstacle information. There might be a situation however where the system is error-prone and may not be able to consistently determine the current environment. This situation can be avoided when the system knows the true position of the obstacle. The quality characteristics of the obstacle data strongly depends on the quality of the source data such as maps and official publications. In some countries such as newly industrializing and developing countries, quality and quantity of obstacle information is not available. The aviation world has two specifications - RTCA DO-276A and ICAO ANNEX 15 Ch. 10 - which describe the requirements for aviation obstacles. It is essential to meet these requirements to be compliant with the specifications and to support systems based on these specifications, e.g. 3D obstacle warning systems where accurate coordinates based on WGS-84 is a necessity. Existing aerial and satellite or soon to exist high quality remote sensing data makes it feasible to think about automated aviation obstacle data origination. This paper will describe the feasibility to auto-extract aviation obstacles from remote sensing data considering limitations of image and extraction technologies. Quality parameters and possible resolution of auto-extracted obstacle data will be discussed and presented.

  14. Real-time dedispersion for fast radio transient surveys, using auto tuning on many-core accelerators

    NASA Astrophysics Data System (ADS)

    Sclocco, A.; van Leeuwen, J.; Bal, H. E.; van Nieuwpoort, R. V.

    2016-01-01

    Dedispersion, the removal of deleterious smearing of impulsive signals by the interstellar matter, is one of the most intensive processing steps in any radio survey for pulsars and fast transients. We here present a study of the parallelization of this algorithm on many-core accelerators, including GPUs from AMD and NVIDIA, and the Intel Xeon Phi. We find that dedispersion is inherently memory-bound. Even in a perfect scenario, hardware limitations keep the arithmetic intensity low, thus limiting performance. We next exploit auto-tuning to adapt dedispersion to different accelerators, observations, and even telescopes. We demonstrate that the optimal settings differ between observational setups, and that auto-tuning significantly improves performance. This impacts time-domain surveys from Apertif to SKA.

  15. Preferential recognition of auto-antibodies against 4-hydroxynonenal modified DNA in the cancer patients.

    PubMed

    Faisal, Mohammad; Shahab, Uzma; Alatar, Abdulrahman A; Ahmad, Saheem

    2017-11-01

    The structural perturbations in DNA molecule may be caused by a break in a strand, a missing base from the backbone, or a chemically changed base. These alterations in DNA that occurs naturally can result from metabolic or hydrolytic processes. DNA damage plays a major role in the mutagenesis, carcinogenesis, aging and various other patho-physiological conditions. DNA damage can be induced through hydrolysis, exposure to reactive oxygen species (ROS) and other reactive carbonyl metabolites including 4-hydroxynonenal (HNE). 4-HNE is an important lipid peroxidation product which has been implicated in the mutagenesis and carcinogenesis processes. The present study examines to probe the presence of auto-antibodies against 4-hydroxynonenal damaged DNA (HNE-DNA) in various cancer subjects. In this study, the purified calf thymus DNA was damaged by the action of 4-HNE. The DNA was incubated with 4-HNE for 24 h at 37°C temperature. The binding characteristics of cancer auto-antibodies were assessed by direct binding and competitive inhibition ELISA. DNA modifications produced hyperchromicity in UV spectrum and decreased fluorescence intensity. Cancer sera exhibited enhanced binding with the 4-HNE modified calf thymus DNA as compared to its native conformer. The 4-HNE modified DNA presents unique epitopes which may be one of the factors for the auto-antibody induction in cancer patients. The HNE modified DNA presents unique epitopes which may be one of the factors for the autoantibody induction in cancer patients. © 2017 Wiley Periodicals, Inc.

  16. [Evaluation of exposure of auto painters to organic solvents in the city of Bogota].

    PubMed

    Palma, Marien; Briceño, Leonardo; Idrovo, Álvaro J; Varona, Marcela

    2015-08-01

    Painters of automobiles are exposed to pure and mixed solvents that have been associated with neurological effects and carcinogenic mutations. To characterize the health and work conditions of individuals who are occupationally exposed to organic solvents used in sheet metal and auto body shops in Bogota. Descriptive, cross-sectional study that characterizes the health and work conditions of individuals exposed to organic solvents in sheet metal and auto body shops in Bogota. A group exposed to the solvents was compared to an unexposed group. Air concentrations of benzene, toluene and xylene (BTX) were determined, individual questionnaires were administered and phenylmercapturic, hippuric and ortho- and para-methylhippuric acids were measured in urine. The results of the measurements and the questionnaires were correlated to determine the exposure panorama. For the three BTX metabolites, statistically significant differences (p<0.001) were found between the population exposed to the solvents and the unexposed population. For the exposed population, positive correlations were found between toluene in air and hippuric acid in urine (rho=0.82) and between xylene in air and o-methylhippuric acid in urine (rho=0.76). Hippuric acid values exceeded permissible levels in 11 workers and p-methylhippuric acid exceeded permissible levels in 8 workers. None of the phenylmercapturic values exceeded the limit. Auto painters are exposed to high levels of organic solvents at the workplace and do not have adequate industrial health and safety conditions to perform their jobs.

  17. The Li(f)e of the Self: Missing Persons and Auto/Archeological Excavations

    ERIC Educational Resources Information Center

    Burdick, Jake

    2014-01-01

    This article describes and enacts a process of autobiographical inquiry, auto/archeology, which seeks to address problematic confluences of memory and identity in reconstructing one's historical narrative. Drawing on curriculum theory and Lacanian psychoanalysis, the author describes a process of excavation in which understandings of a prior…

  18. The Auto-Gopher Deep Drill

    NASA Technical Reports Server (NTRS)

    Badescu, Mircea

    2014-01-01

    Subsurface penetration by coring, drilling or abrading is of great importance for a large number of space and earth applications. An Ultrasonic/Sonic Drill/Corer (USDC) has been in development at JPL's Nondestructive Evaluation and Advanced Actuators (NDEAA) lab as an adaptable tool for many of these applications. The USDC uses a novel drive mechanism to transform the high frequency ultrasonic or sonic vibrations of the tip of a horn into a lower frequency sonic hammering of a drill bit through an intermediate free-flying mass. The USDC device idea has been implemented at various scales from handheld drills to large diameter coring devices. A series of computer programs that model the function and performance of the USDC device were developed and were later integrated into an automated modeling package. The USDC has also evolved from a purely hammering drill to a rotary hammer drill as the design requirements increased form small diameter shallow drilling to large diameter deep coring. A synthesis of the Auto-Gopher development is presented in this paper.

  19. Auto white balance method using a pigmentation separation technique for human skin color

    NASA Astrophysics Data System (ADS)

    Tanaka, Satomi; Kakinuma, Akihiro; Kamijo, Naohiro; Takahashi, Hiroshi; Tsumura, Norimichi

    2017-02-01

    The human visual system maintains the perception of colors of an object across various light sources. Similarly, current digital cameras feature an auto white balance function, which estimates the illuminant color and corrects the color of a photograph as if the photograph was taken under a certain light source. The main subject in a photograph is often a person's face, which could be used to estimate the illuminant color. However, such estimation is adversely affected by differences in facial colors among individuals. The present paper proposes an auto white balance algorithm based on a pigmentation separation method that separates the human skin color image into the components of melanin, hemoglobin and shading. Pigment densities have a uniform property within the same race that can be calculated from the components of melanin and hemoglobin in the face. We, thus, propose a method that uses the subject's facial color in an image and is unaffected by individual differences in facial color among Japanese people.

  20. QuickVina: accelerating AutoDock Vina using gradient-based heuristics for global optimization.

    PubMed

    Handoko, Stephanus Daniel; Ouyang, Xuchang; Su, Chinh Tran To; Kwoh, Chee Keong; Ong, Yew Soon

    2012-01-01

    Predicting binding between macromolecule and small molecule is a crucial phase in the field of rational drug design. AutoDock Vina, one of the most widely used docking software released in 2009, uses an empirical scoring function to evaluate the binding affinity between the molecules and employs the iterated local search global optimizer for global optimization, achieving a significantly improved speed and better accuracy of the binding mode prediction compared its predecessor, AutoDock 4. In this paper, we propose further improvement in the local search algorithm of Vina by heuristically preventing some intermediate points from undergoing local search. Our improved version of Vina-dubbed QVina-achieved a maximum acceleration of about 25 times with the average speed-up of 8.34 times compared to the original Vina when tested on a set of 231 protein-ligand complexes while maintaining the optimal scores mostly identical. Using our heuristics, larger number of different ligands can be quickly screened against a given receptor within the same time frame.

  1. [Quantitative analysis of the corneal subbasal nerves in different degrees of dry eye with AutoCAD].

    PubMed

    Cheng, Y; Wu, J; Zhu, H F; Cheng, Y; Zhu, X P

    2016-03-01

    To evaluate the practical value of AutoCAD in quantitative analysis of corneal subbasal epithelial nerves with different degrees of dry eye. Ninety patients were divided into groups of mild, moderate, and severe dry eye, 30 patients (60 eyes) in each group. And 30 healthy volunteers were recruited as the normal control group. Confocal microscopy was used to observe the length of the subbasal epithelial nerve plexus. The images were analyzed by AutoCAD software to determine the density (mm/mm(2)), the number of branches, and the curvature score of the subbasal epithelial nerves. These data of patients with dry eye and the controls were statistically compared, by analysis of variance(ANOV). By AutoCAD software, quantitative analysis of the corneal subbasal epithelial nerves was successfully performed. The nerve density in the patients with mild dry eye[(16.70±3.43) mm/mm(2)] was not significantly different from the controls[(15.87 ± 2.75) mm/mm(2)] (P=0.880), but the number of nerval branches 13.43±2.46 and the curvature 3.10±0.80 increased significantly (P<0.001). The nerve density in the patients with moderate and severe dry eye was significantly different from that in the normal control group (F=114.739, P<0.001). The neural density was significantly lower in the patients with severe dry eye than the controls, but there was no significant difference in the curvature scores between the two groups (P= 0.557). AutoCAD software is useful in the quantitative analysis of corneal nerve images under a confocal microscope. The corneal subbasal epithelial nerve density, the number of branches, and the curvature of the nerves are related to the degree of dry eye, and may be used as clinical indicators.

  2. Auto-antibodies in prostate cancer: humoral immune response to antigenic determinants coded by the differentially expressed transcripts FLJ23438 and VAMP3.

    PubMed

    Pontes, E R; Matos, L C; da Silva, E A; Xavier, L S; Diaz, B L; Small, I A; Reis, E M; Verjovski-Almeida, S; Barcinski, M A; Gimba, E R P

    2006-10-01

    Here we evaluate auto-antibody response against two potential antigenic determinants of genes highly expressed in low Gleason Score prostate cancer (PC) tumor samples, namely FLJ23438 and VAMP3. RT-PCR assays were used to analyze mRNA expression profiles of FLJ23438 and VAMP3 transcripts. The auto-antibody response against FLJ23438 and VAMP3 recombinant proteins was tested by immunoblot assays using PC, benign prostate hyperplasia (BPH), healthy donors (HD), and other human cancers plasma samples. Our data showed that 37% (10/27) and 7.4% (2/27) of PC plasma samples presented auto-antibodies against FLJ23438 and VAMP3, respectively. Only 8.3% (1/12) of BPH plasma samples were reactive for both auto-antibodies, while none (0/12) of HD plasma samples tested were reactive. The prevalence of 37% of positive PC plasma samples for anti-FLJ23438 antibodies suggests that humoral immune response against this antigenic determinant could be a potential serum marker for this cancer. (c) 2006 Wiley-Liss, Inc.

  3. Prevalence of menstrual cycles and outcome of 50 pregnancies after high-dose chemotherapy and auto-SCT in non-Hodgkin and Hodgkin lymphoma patients younger than 40 years.

    PubMed

    Akhtar, S; Youssef, I; Soudy, H; Elhassan, T A M; Rauf, S M; Maghfoor, I

    2015-12-01

    Data are limited regarding the prevalence of menstrual cycles and pregnancies after high-dose chemotherapy (HDC) and auto-stem cell transplantation (SCT). Female patients who underwent HDC auto-SCT for non-Hodgkin and Hodgkin lymphoma (1997-2012) were reviewed. The selection criteria were as follows: (1) alive without disease 12 and 24 months after auto-SCT for menstrual cycles and pregnancy, respectively, (2) age <40 years at auto-SCT, and (3) no primary infertility. One-hundred and seventy-six females underwent single auto-SCT. Eighty-nine were eligible for menstrual cycles and pregnancy analysis. Median age at auto-SCT was 25 years (14-40 years), at pregnancy 27 years (20-37 years), median follow-up 65 months (range 24-190). Regular menstrual-cycles resumed in 56/89 patients (63%). Increasing age (P=0.02) and number of prior chemotherapy cycles (P=0.02) are associated with higher risk of amenorrhea. Forty patients tried to get pregnant, 26 (65%) became pregnant 50 times: 43 (86%) live birth, 7 (14%) miscarriage and 2/50 had birth defects. Twenty-four patients practiced breastfeeding (median duration 4 months (1-24 months)). Enough breast milk production was reported 62.5% vs 100% in those patients who did or did not receive above the diaphragm radiation therapy, respectively, (P=0.066). Our data highlights significantly higher than perceived incidence of menstrual cycle resumption, successful pregnancies and breastfeeding after HDC auto-SCT.

  4. The Auto Industry's New Model. Car Companies and Community Colleges Collaborate to Provide High-Technology Training.

    ERIC Educational Resources Information Center

    Cantor, Jeffrey A.

    1991-01-01

    Major auto manufacturers have developed cooperative apprenticeship programs with community colleges, offering alternating periods of study and work experience under the supervision of master technicians. (SK)

  5. Reference Aid: Glossary of Acronyms, Abbreviations, and Special Terms Used in the Western Europe Romance-Language Press.

    DTIC Science & Technology

    1977-11-25

    Fr) Legere Car (Fr) Auto Light Machine AM Metralhadora Gun (Por) Aviazione Air Force Ligeira Militare (Ita) AMN Adetto Military Ansaldo...Italian Socialist Youth Federation (Ita) General Federa- tion of Labor of Belgium (Bel) 52 FIA Federation International de 1’ Auto ...Obrero Auto - gestionario Self-Management Workers Move- ment (Spa) MOC Mouvement des Ouvriers Chretiens Mocidade Portuguese MODEF Mouvement de

  6. Pick-N-Pull Auto Dismantlers, Kansas City, LLC Inc. - Clean Water Act Public Notice

    EPA Pesticide Factsheets

    The EPA is providing notice of a proposed Administrative Penalty Assessment against Pick-N-Pull Auto Dismantlers, Kansas City, LLC, a subsidiary of Schnitzer Steel Industries, Inc., for alleged violations at its facilities at 8012 East Truman Rd., Kansas C

  7. Acceleration of atmospheric Cherenkov telescope signal processing to real-time speed with the Auto-Pipe design system

    NASA Astrophysics Data System (ADS)

    Tyson, Eric J.; Buckley, James; Franklin, Mark A.; Chamberlain, Roger D.

    2008-10-01

    The imaging atmospheric Cherenkov technique for high-energy gamma-ray astronomy is emerging as an important new technique for studying the high energy universe. Current experiments have data rates of ≈20TB/year and duty cycles of about 10%. In the future, more sensitive experiments may produce up to 1000 TB/year. The data analysis task for these experiments requires keeping up with this data rate in close to real-time. Such data analysis is a classic example of a streaming application with very high performance requirements. This class of application often benefits greatly from the use of non-traditional approaches for computation including using special purpose hardware (FPGAs and ASICs), or sophisticated parallel processing techniques. However, designing, debugging, and deploying to these architectures is difficult and thus they are not widely used by the astrophysics community. This paper presents the Auto-Pipe design toolset that has been developed to address many of the difficulties in taking advantage of complex streaming computer architectures for such applications. Auto-Pipe incorporates a high-level coordination language, functional and performance simulation tools, and the ability to deploy applications to sophisticated architectures. Using the Auto-Pipe toolset, we have implemented the front-end portion of an imaging Cherenkov data analysis application, suitable for real-time or offline analysis. The application operates on data from the VERITAS experiment, and shows how Auto-Pipe can greatly ease performance optimization and application deployment of a wide variety of platforms. We demonstrate a performance improvement over a traditional software approach of 32x using an FPGA solution and 3.6x using a multiprocessor based solution.

  8. Simultaneous auto-calibration and gradient delays estimation (SAGE) in non-Cartesian parallel MRI using low-rank constraints.

    PubMed

    Jiang, Wenwen; Larson, Peder E Z; Lustig, Michael

    2018-03-09

    To correct gradient timing delays in non-Cartesian MRI while simultaneously recovering corruption-free auto-calibration data for parallel imaging, without additional calibration scans. The calibration matrix constructed from multi-channel k-space data should be inherently low-rank. This property is used to construct reconstruction kernels or sensitivity maps. Delays between the gradient hardware across different axes and RF receive chain, which are relatively benign in Cartesian MRI (excluding EPI), lead to trajectory deviations and hence data inconsistencies for non-Cartesian trajectories. These in turn lead to higher rank and corrupted calibration information which hampers the reconstruction. Here, a method named Simultaneous Auto-calibration and Gradient delays Estimation (SAGE) is proposed that estimates the actual k-space trajectory while simultaneously recovering the uncorrupted auto-calibration data. This is done by estimating the gradient delays that result in the lowest rank of the calibration matrix. The Gauss-Newton method is used to solve the non-linear problem. The method is validated in simulations using center-out radial, projection reconstruction and spiral trajectories. Feasibility is demonstrated on phantom and in vivo scans with center-out radial and projection reconstruction trajectories. SAGE is able to estimate gradient timing delays with high accuracy at a signal to noise ratio level as low as 5. The method is able to effectively remove artifacts resulting from gradient timing delays and restore image quality in center-out radial, projection reconstruction, and spiral trajectories. The low-rank based method introduced simultaneously estimates gradient timing delays and provides accurate auto-calibration data for improved image quality, without any additional calibration scans. © 2018 International Society for Magnetic Resonance in Medicine.

  9. Tensile bond strength between auto-polymerized acrylic resin and acrylic denture teeth treated with MF-MA solution.

    PubMed

    Thongrakard, Ticha; Wiwatwarrapan, Chairat

    2016-08-01

    This study evaluated the effect of chemical surface treatment using methyl formate-methyl acetate (MF-MA) solution on the tensile bond strength between acrylic denture teeth and auto-polymerized acrylic resin. Seventy maxillary central incisor acrylic denture teeth for each of three different brands (Yamahachi New Ace; Major Dent; Cosmo HXL) were embedded with incisal edge downwards in auto-polymerized resin in polyethylene pipes and ground with silicone carbide paper on their ridge lap surfaces. The teeth of each brand were divided into seven groups (n=10): no surface treatment (control group), MF-MA solution at a ratio of 25:75 (v/v) for 15 seconds, 30 seconds, 60 seconds, 120 seconds, 180 seconds, and MMA for 180 seconds. Auto-polymerized acrylic resin (Unifast Trad) was applied to the ground surface and polymerized in a pressure cooker. A tensile strength test was performed with a universal testing machine. Statistical analysis of the results was performed using two-way analysis of variance (ANOVA) and post-hoc Dunnett T3 test (α=.05). The surface treatment groups had significantly higher mean tensile bond strengths compared with the control group (P<.05) when compared within the same brand. Among the surface treatment groups of each brand, there were no significantly different tensile bond strengths between the MF-MA groups and the MMA 180 second group (P>.05), except for the Yamahachi New Ace MF-MA 180-second group (P<.05). 15-second MF-MA solution can be an alternative chemical surface treatment for repairing a denture base and rebonding acrylic denture teeth with auto-polymerized acrylic resin, for both conventional and cross-linked teeth.

  10. Effective comparison of two auto-CPAP devices for treatment of obstructive sleep apnea based on polysomnographic evaluation.

    PubMed

    Shi, Hai-Bo; Cheng, Lei; Nakayama, Meiho; Kakazu, Yasuhiro; Yin, Min; Miyoshi, Akira; Komune, Shizuo

    2005-09-01

    Automatic continuous positive airway pressure (auto-CPAP) machines differ mainly in algorithms used for respiratory event detection and pressure control. The auto-CPAP machines operated by novel algorithms are expected to have better performance than the earlier ones in the treatment of obstructive sleep apnea syndrome (OSAS). The purpose of this study was to determine the therapeutic characteristics between two different auto-CPAP devices, i.e., the third-generation flow-based (f-APAP) and the second-generation vibration-based (v-APAP) machines, during the first night treatment of OSAS. We retrospectively reviewed the polysomnography (PSG) recordings of 43 OSAS patients who were initially performed an overnight diagnostic PSG to confirm the disease and afterwards received the first night auto-CPAP treatment with using either the f-APAP (n=22) or v-APAP (n=21) device under another PSG evaluation. There were 13.6% and 61.9% patients who remained a residual apnea/hypopnea index more than 5 during the f-APAP and v-APAP application, respectively (P<0.005). The f-APAP was more effective than the v-APAP in reducing apnea/hypopnea index (P=0.003), hypopnea index (P=0.023) and apnea index (P=0.007), improving the lowest oxygen saturation index (P=0.007) and shortening stage 1 sleep (P=0.016). However, the f-APAP was less sufficient than the v-APAP in reducing arousal/awakening index (P=0.02). These findings suggest that the f-APAP works better than the v-APAP in abolishing breathing abnormities in the treatment of OSAS; however, the f-APAP device might still have some potential limitations in the clinical application.

  11. Web Proxy Auto Discovery for the WLCG

    NASA Astrophysics Data System (ADS)

    Dykstra, D.; Blomer, J.; Blumenfeld, B.; De Salvo, A.; Dewhurst, A.; Verguilov, V.

    2017-10-01

    All four of the LHC experiments depend on web proxies (that is, squids) at each grid site to support software distribution by the CernVM FileSystem (CVMFS). CMS and ATLAS also use web proxies for conditions data distributed through the Frontier Distributed Database caching system. ATLAS & CMS each have their own methods for their grid jobs to find out which web proxies to use for Frontier at each site, and CVMFS has a third method. Those diverse methods limit usability and flexibility, particularly for opportunistic use cases, where an experiment’s jobs are run at sites that do not primarily support that experiment. This paper describes a new Worldwide LHC Computing Grid (WLCG) system for discovering the addresses of web proxies. The system is based on an internet standard called Web Proxy Auto Discovery (WPAD). WPAD is in turn based on another standard called Proxy Auto Configuration (PAC). Both the Frontier and CVMFS clients support this standard. The input into the WLCG system comes from squids registered in the ATLAS Grid Information System (AGIS) and CMS SITECONF files, cross-checked with squids registered by sites in the Grid Configuration Database (GOCDB) and the OSG Information Management (OIM) system, and combined with some exceptions manually configured by people from ATLAS and CMS who operate WLCG Squid monitoring. WPAD servers at CERN respond to http requests from grid nodes all over the world with a PAC file that lists available web proxies, based on IP addresses matched from a database that contains the IP address ranges registered to organizations. Large grid sites are encouraged to supply their own WPAD web servers for more flexibility, to avoid being affected by short term long distance network outages, and to offload the WLCG WPAD servers at CERN. The CERN WPAD servers additionally support requests from jobs running at non-grid sites (particularly for LHC@Home) which they direct to the nearest publicly accessible web proxy servers. The responses

  12. Redlining or Risk? A Spatial Analysis of Auto Insurance Rates in Los Angeles

    ERIC Educational Resources Information Center

    Ong, Paul M.; Stoll, Michael A.

    2007-01-01

    Auto insurance rates can vary dramatically, with much higher premiums in poor and minority areas than elsewhere, even after accounting for individual characteristics, driving history, and coverage. This paper uses a unique data set to examine the relative influence of place-based socioeconomic characteristics (or redlining) and place-based risk…

  13. High density growth of T7 expression strains with auto-induction option

    DOEpatents

    Studier, F. William

    2013-03-19

    A method for promoting and suppressing auto-induction of transcription of a cloned gene 1 of bacteriophage T7 in cultures of bacterial cells grown batchwise is disclosed. The transcription is under the control of a promoter whose activity can be induced by an exogenous inducer whose ability to induce said promoter is dependent on the metabolic state of said bacterial cells.

  14. Prototype of an auto-calibrating, context-aware, hybrid brain-computer interface.

    PubMed

    Faller, J; Torrellas, S; Miralles, F; Holzner, C; Kapeller, C; Guger, C; Bund, J; Müller-Putz, G R; Scherer, R

    2012-01-01

    We present the prototype of a context-aware framework that allows users to control smart home devices and to access internet services via a Hybrid BCI system of an auto-calibrating sensorimotor rhythm (SMR) based BCI and another assistive device (Integra Mouse mouth joystick). While there is extensive literature that describes the merit of Hybrid BCIs, auto-calibrating and co-adaptive ERD BCI training paradigms, specialized BCI user interfaces, context-awareness and smart home control, there is up to now, no system that includes all these concepts in one integrated easy-to-use framework that can truly benefit individuals with severe functional disabilities by increasing independence and social inclusion. Here we integrate all these technologies in a prototype framework that does not require expert knowledge or excess time for calibration. In a first pilot-study, 3 healthy volunteers successfully operated the system using input signals from an ERD BCI and an Integra Mouse and reached average positive predictive values (PPV) of 72 and 98% respectively. Based on what we learned here we are planning to improve the system for a test with a larger number of healthy volunteers so we can soon bring the system to benefit individuals with severe functional disability.

  15. Selective activators of protein phosphatase 5 target the auto-inhibitory mechanism.

    PubMed

    Haslbeck, Veronika; Drazic, Adrian; Eckl, Julia M; Alte, Ferdinand; Helmuth, Martin; Popowicz, Grzegorz; Schmidt, Werner; Braun, Frank; Weiwad, Matthias; Fischer, Gunter; Gemmecker, Gerd; Sattler, Michael; Striggow, Frank; Groll, Michael; Richter, Klaus

    2015-04-20

    Protein phosphatase 5 (PP5) is an evolutionary conserved serine/threonine phosphatase. Its dephosphorylation activity modulates a diverse set of cellular factors including protein kinases and the microtubule-associated tau protein involved in neurodegenerative disorders. It is auto-regulated by its heat-shock protein (Hsp90)-interacting tetratricopeptide repeat (TPR) domain and its C-terminal α-helix. In the present study, we report the identification of five specific PP5 activators [PP5 small-molecule activators (P5SAs)] that enhance the phosphatase activity up to 8-fold. The compounds are allosteric modulators accelerating efficiently the turnover rate of PP5, but do barely affect substrate binding or the interaction between PP5 and the chaperone Hsp90. Enzymatic studies imply that the compounds bind to the phosphatase domain of PP5. For the most promising compound crystallographic comparisons of the apo PP5 and the PP5-P5SA-2 complex indicate a relaxation of the auto-inhibited state of PP5. Residual electron density and mutation analyses in PP5 suggest activator binding to a pocket in the phosphatase/TPR domain interface, which may exert regulatory functions. These compounds thus may expose regulatory mechanisms in the PP5 enzyme and serve to develop optimized activators based on these scaffolds. © 2015 Authors.

  16. Open-RAC: Open-Design, Recirculating and Auto-Cleaning Zebrafish Maintenance System.

    PubMed

    Nema, Shubham; Bhargava, Yogesh

    2017-08-01

    Zebrafish is a vertebrate animal model. Their maintenance in large number under laboratory conditions is a daunting task. Commercially available recirculating zebrafish maintenance systems are used to efficiently handle the tasks of automatic sediment cleaning from zebrafish tanks with minimal waste of water. Due to their compact nature, they also ensure the maximal use of available lab space. However, the high costs of commercial systems present a limitation to researchers with limited funds. A cost-effective zebrafish maintenance system with major features offered by commercially available systems is highly desirable. Here, we describe a compact and recirculating zebrafish maintenance system. Our system is composed of cost-effective components, which are available in local markets and/or can be procured via online vendors. Depending on the expertise of end users, the system can be assembled in 2 days. The system is completely customizable as it offers geometry independent zebrafish tanks that are capable of auto-cleaning the sediments. Due to these features, we called our setup as Open-RAC (Open-design, Recirculating and Auto-Cleaning zebrafish maintenance system). Open-RAC is a cost-effective and viable alternative to the currently available zebrafish maintenance systems. Thus, we believe that the use of Open-RAC could promote the zebrafish research by removing the cost barrier for researchers.

  17. A new approach to the form and position error measurement of the auto frame surface based on laser

    NASA Astrophysics Data System (ADS)

    Wang, Hua; Li, Wei

    2013-03-01

    Auto frame is a very large workpiece, with length up to 12 meters and width up to 2 meters, and it's very easy to know that it's inconvenient and not automatic to measure such a large workpiece by independent manual operation. In this paper we propose a new approach to reconstruct the 3D model of the large workpiece, especially the auto truck frame, based on multiple pulsed lasers, for the purpose of measuring the form and position errors. In a concerned area, it just needs one high-speed camera and two lasers. It is a fast, high-precision and economical approach.

  18. Effect of surface treatment methods on the shear bond strength of auto-polymerized resin to thermoplastic denture base polymer.

    PubMed

    Koodaryan, Roodabeh; Hafezeqoran, Ali

    2016-12-01

    Polyamide polymers do not provide sufficient bond strength to auto-polymerized resins for repairing fractured denture or replacing dislodged denture teeth. Limited treatment methods have been developed to improve the bond strength between auto-polymerized reline resins and polyamide denture base materials. The objective of the present study was to evaluate the effect of surface modification by acetic acid on surface characteristics and bond strength of reline resin to polyamide denture base. 84 polyamide specimens were divided into three surface treatment groups (n=28): control (N), silica-coated (S), and acid-treated (A). Two different auto-polymerized reline resins GC and Triplex resins were bonded to the samples (subgroups T and G, respectively, n=14). The specimens were subjected to shear bond strength test after they were stored in distilled water for 1 week and thermo-cycled for 5000 cycles. Data were analyzed with independent t-test, two-way analysis of variance (ANOVA), and Tukey's post hoc multiple comparison test (α=.05). The bond strength values of A and S were significantly higher than those of N ( P <.001 for both). However, statistically significant difference was not observed between group A and group S. According to the independent Student's t-test, the shear bond strength values of AT were significantly higher than those of AG ( P <.001). The surface treatment of polyamide denture base materials with acetic acid may be an efficient and cost-effective method for increasing the shear bond strength to auto-polymerized reline resin.

  19. Footy, Gangs and Love: Using Auto-Ethnography to Problematise Practice on a Practicum

    ERIC Educational Resources Information Center

    Bellamy, Roz

    2017-01-01

    This article was written as an auto ethnography, which allowed for a complex and personal exploration of professional standards, teachers' professional identities, neoliberal reforms, and approaches to literacy and creativity. This article reflects on a practicum which involved teaching Romeo and Juliet to two year nine classes at an all boys'…

  20. Study of weld quality real-time monitoring system for auto-body assembly

    NASA Astrophysics Data System (ADS)

    Xu, Jun; Li, Yong-Bing; Chen, Guan-Long

    2005-12-01

    Resistance spot welding (RSW) is widely used for the auto-body assembly in automotive industry. But RSW suffers from a major problem of inconsistent quality from weld to weld. The major problem is the complexity of the basic process that may involve material coatings, electrode force, electrode wear, fit up, etc. Therefore weld quality assurance is still a big challenge and goal. Electrode displacement has proved to be a particularly useful signal which correlates well with weld quality. This paper introduces a novel auto-body spot weld quality monitoring system which uses electrode displacement as the quality parameter. This system chooses the latest laser displacement sensor with high resolution to measure the real-time electrode displacement. It solves the interference problem of sensor mounting by designing special fixture, and can be successfully applied on the portable welding machine. It is capable of evaluating weld quality and making diagnosis of process variations such as surface asperities, shunting, worn electrode and weld expansion with real-time electrode displacement. As proved by application in the workshop, the monitoring system has good stability and reliability, and is qualified for monitoring weld quality in process.

  1. Efficacy of dry-ice blasting in preventive maintenance of auto robotic assemblies

    NASA Astrophysics Data System (ADS)

    Baluch, Nazim; Mohtar, Shahimi; Abdullah, Che Sobry

    2016-08-01

    Welding robots are extensively applied in the automotive assemblies and `Spot Welding' is the most common welding application found in the auto stamping assembly manufacturing. Every manufacturing process is subject to variations - with resistance welding, these include; part fit up, part thickness variations, misaligned electrodes, variations in coating materials or thickness, sealers, weld force variations, shunting, machine tooling degradation; and slag and spatter damage. All welding gun tips undergo wear; an elemental part of the process. Though adaptive resistance welding control automatically compensates to keep production and quality up to the levels needed as gun tips undergo wear so that the welds remain reliable; the system cannot compensate for deterioration caused by the slag and spatter on the part holding fixtures, sensors, and gun tips. To cleanse welding robots of slag and spatter, dry-ice blasting has proven to be an effective remedy. This paper describes Spot welding process, analyses the slag and spatter formation during robotic welding of stamping assemblies, and concludes that the dry ice blasting process's utility in cleansing of welding robots in auto stamping plant operations is paramount and exigent.

  2. Onset of nonlinearity in a stochastic model for auto-chemotactic advancing epithelia

    NASA Astrophysics Data System (ADS)

    Ben Amar, Martine; Bianca, Carlo

    2016-09-01

    We investigate the role of auto-chemotaxis in the growth and motility of an epithelium advancing on a solid substrate. In this process, cells create their own chemoattractant allowing communications among neighbours, thus leading to a signaling pathway. As known, chemotaxis provokes the onset of cellular density gradients and spatial inhomogeneities mostly at the front, a phenomenon able to predict some features revealed in in vitro experiments. A continuous model is proposed where the coupling between the cellular proliferation, the friction on the substrate and chemotaxis is investigated. According to our results, the friction and proliferation stabilize the front whereas auto-chemotaxis is a factor of destabilization. This antagonist role induces a fingering pattern with a selected wavenumber k0. However, in the planar front case, the translational invariance of the experimental set-up gives also a mode at k = 0 and the coupling between these two modes in the nonlinear regime is responsible for the onset of a Hopf-bifurcation. The time-dependent oscillations of patterns observed experimentally can be predicted simply in this continuous non-linear approach. Finally the effects of noise are also investigated below the instability threshold.

  3. Portable exhauster POR-007/Skid E and POR-008/Skid F storage plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, O.D.

    1998-07-25

    This document provides storage requirements for 1,000 CFM portable exhausters POR-O07/Skid E and POR-008/Skid F. These requirements are presented in three parts: preparation for storage, storage maintenance and testing, and retrieval from storage. The exhauster component identification numbers listed in this document contain the prefix POR-007 or POR-008 depending on which exhauster is being used.

  4. Auto-Targeted Neurostimulation Is Not Superior to Placebo in Chronic Low Back Pain: A Fourfold Blind Randomized Clinical Trial.

    PubMed

    Aguilar Ferrándiz, Maria Encarnación; Nijs, Jo; Gidron, Yori; Roussel, Nathalie; Vanderstraeten, Rob; Van Dyck, Dries; Huysmans, Eva; De Kooning, Margot

    2016-07-01

    Myofascial trigger points (MTrPs) are common in people with musculoskeletal pain and may play a role in chronic nonspecific low back pain (CLBP). One of the potential treatments of MTrPs is the Nervomatrix Soleve® auto-targeted neurostimulation device, providing targeted transcutaneous electrical nerve stimulation (TENS) to MTrPs in the lower back muscles. To date, no controlled studies have evaluated the effectiveness of this device for the pain management of this population. To examine whether the Nervomatrix Soleve® auto-targeted neurostimulation device is superior over placebo for the treatment of CLBP. A fourfold-blind randomized controlled trial was conducted. Brussels University Hospital, health care centers and pharmacies around Belgium. Participants with CLBP for at least 3 months were randomly assigned to the experimental (the Nervomatrix Soleve® auto-targeted neurostimulation device providing TENS-stimulation and mechanical pressure) or placebo group (the Nervomatrix Soleve® auto-targeted neurostimulation device providing mechanical pressure alone without current). The treatment protocol in both groups consisted of 6 treatment sessions per patient. Participants were evaluated at baseline prior to the intervention, immediately following treatment, and at one month follow-up. Pain and pain behavior (steps climbed) were assessed as primary outcome measures. Secondary outcome measures were pain functioning, health beliefs, symptoms of central sensitization, pain catastrophizing, and kinesiophobia. In total, 39 participants were included in the study. Participants in both groups improved significantly for pain and functioning, but no significant differences were observed between groups. These improvements were not clinically meaningful for any of the reported measures. The health beliefs changed significantly in both groups (P < 0.05), with superior results at follow-up in the placebo group. The follow-up period is limited to one month. Treatment of MTr

  5. SU-E-I-97: Smart Auto-Planning Framework in An EMR Environment (SAFEE)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, B; Chen, S; Mutaf, Y

    2014-06-01

    Purpose: Our Radiation Oncology Department uses clinical practice guidelines for patient treatment, including normal tissue sparing and other dosimetric constraints. These practice guidelines were adapted from national guidelines, clinical trials, literature reviews, and practitioner's own experience. Modern treatment planning systems (TPS) have the capability of incorporating these practice guidelines to automatically create radiation therapy treatment plans with little human intervention. We are developing a software infrastructure to integrate clinical practice guidelines and radiation oncology electronic medical record (EMR) system into radiation therapy treatment planning system (TPS) for auto planning. Methods: Our Smart Auto-Planning Framework in an EMR environment (SAFEE) usesmore » a software pipeline framework to integrate practice guidelines,EMR, and TPS together. The SAFEE system starts with retrieving diagnosis information and physician's prescription from the EMR system. After approval of contouring, SAFEE will automatically create plans according to our guidelines. Based on clinical objectives, SAFEE will automatically select treatment delivery techniques (such as, 3DRT/IMRT/VMAT) and optimize plans. When necessary, SAFEE will create multiple treatment plans with different combinations of parameters. SAFEE's pipeline structure makes it very flexible to integrate various techniques, such as, Model-Base Segmentation (MBS) and plan optimization algorithms, e.g., Multi-Criteria Optimization (MCO). In addition, SAFEE uses machine learning, data mining techniques, and an integrated database to create clinical knowledgebase and then answer clinical questions, such as, how to score plan quality or how volume overlap affects physicians' decision in beam and treatment technique selection. Results: In our institution, we use Varian Aria EMR system and RayStation TPS from RaySearch, whose ScriptService API allows control by external programs. These

  6. Programmable logic controller implementation of an auto-tuned predictive control based on minimal plant information.

    PubMed

    Valencia-Palomo, G; Rossiter, J A

    2011-01-01

    This paper makes two key contributions. First, it tackles the issue of the availability of constrained predictive control for low-level control loops. Hence, it describes how the constrained control algorithm is embedded in an industrial programmable logic controller (PLC) using the IEC 61131-3 programming standard. Second, there is a definition and implementation of a novel auto-tuned predictive controller; the key novelty is that the modelling is based on relatively crude but pragmatic plant information. Laboratory experiment tests were carried out in two bench-scale laboratory systems to prove the effectiveness of the combined algorithm and hardware solution. For completeness, the results are compared with a commercial proportional-integral-derivative (PID) controller (also embedded in the PLC) using the most up to date auto-tuning rules. Copyright © 2010 ISA. Published by Elsevier Ltd. All rights reserved.

  7. Rotation invariant eigenvessels and auto-context for retinal vessel detection

    NASA Astrophysics Data System (ADS)

    Montuoro, Alessio; Simader, Christian; Langs, Georg; Schmidt-Erfurth, Ursula

    2015-03-01

    Retinal vessels are one of the few anatomical landmarks that are clearly visible in various imaging modalities of the eye. As they are also relatively invariant to disease progression, retinal vessel segmentation allows cross-modal and temporal registration enabling exact diagnosing for various eye diseases like diabetic retinopathy, hypertensive retinopathy or age-related macular degeneration (AMD). Due to the clinical significance of retinal vessels many different approaches for segmentation have been published in the literature. In contrast to other segmentation approaches our method is not specifically tailored to the task of retinal vessel segmentation. Instead we utilize a more general image classification approach and show that this can achieve comparable results. In the proposed method we utilize the concepts of eigenfaces and auto-context. Eigenfaces have been described quite extensively in the literature and their performance is well known. They are however quite sensitive to translation and rotation. The former was addressed by computing the eigenvessels in local image windows of different scales, the latter by estimating and correcting the local orientation. Auto-context aims to incorporate automatically generated context information into the training phase of classification approaches. It has been shown to improve the performance of spinal cord segmentation4 and 3D brain image segmentation. The proposed method achieves an area under the receiver operating characteristic (ROC) curve of Az = 0.941 on the DRIVE data set, being comparable to current state-of-the-art approaches.

  8. Chemical Space Expansion of Bromodomain Ligands Guided by in Silico Virtual Couplings (AutoCouple).

    PubMed

    Batiste, Laurent; Unzue, Andrea; Dolbois, Aymeric; Hassler, Fabrice; Wang, Xuan; Deerain, Nicholas; Zhu, Jian; Spiliotopoulos, Dimitrios; Nevado, Cristina; Caflisch, Amedeo

    2018-02-28

    Expanding the chemical space and simultaneously ensuring synthetic accessibility is of upmost importance, not only for the discovery of effective binders for novel protein classes but, more importantly, for the development of compounds against hard-to-drug proteins. Here, we present AutoCouple, a de novo approach to computational ligand design focused on the diversity-oriented generation of chemical entities via virtual couplings. In a benchmark application, chemically diverse compounds with low-nanomolar potency for the CBP bromodomain and high selectivity against the BRD4(1) bromodomain were achieved by the synthesis of about 50 derivatives of the original fragment. The binding mode was confirmed by X-ray crystallography, target engagement in cells was demonstrated, and antiproliferative activity was showcased in three cancer cell lines. These results reveal AutoCouple as a useful in silico coupling method to expand the chemical space in hit optimization campaigns resulting in potent, selective, and cell permeable bromodomain ligands.

  9. Novel auto-correction method in a fiber-optic distributed-temperature sensor using reflected anti-Stokes Raman scattering.

    PubMed

    Hwang, Dusun; Yoon, Dong-Jin; Kwon, Il-Bum; Seo, Dae-Cheol; Chung, Youngjoo

    2010-05-10

    A novel method for auto-correction of fiber optic distributed temperature sensor using anti-Stokes Raman back-scattering and its reflected signal is presented. This method processes two parts of measured signal. One part is the normal back scattered anti-Stokes signal and the other part is the reflected signal which eliminate not only the effect of local losses due to the micro-bending or damages on fiber but also the differential attenuation. Because the beams of the same wavelength are used to cancel out the local variance in transmission medium there is no differential attenuation inherently. The auto correction concept was verified by the bending experiment on different bending points. (c) 2010 Optical Society of America.

  10. Tumour auto-contouring on 2d cine MRI for locally advanced lung cancer: A comparative study.

    PubMed

    Fast, Martin F; Eiben, Björn; Menten, Martin J; Wetscherek, Andreas; Hawkes, David J; McClelland, Jamie R; Oelfke, Uwe

    2017-12-01

    Radiotherapy guidance based on magnetic resonance imaging (MRI) is currently becoming a clinical reality. Fast 2d cine MRI sequences are expected to increase the precision of radiation delivery by facilitating tumour delineation during treatment. This study compares four auto-contouring algorithms for the task of delineating the primary tumour in six locally advanced (LA) lung cancer patients. Twenty-two cine MRI sequences were acquired using either a balanced steady-state free precession or a spoiled gradient echo imaging technique. Contours derived by the auto-contouring algorithms were compared against manual reference contours. A selection of eight image data sets was also used to assess the inter-observer delineation uncertainty. Algorithmically derived contours agreed well with the manual reference contours (median Dice similarity index: ⩾0.91). Multi-template matching and deformable image registration performed significantly better than feature-driven registration and the pulse-coupled neural network (PCNN). Neither MRI sequence nor image orientation was a conclusive predictor for algorithmic performance. Motion significantly degraded the performance of the PCNN. The inter-observer variability was of the same order of magnitude as the algorithmic performance. Auto-contouring of tumours on cine MRI is feasible in LA lung cancer patients. Despite large variations in implementation complexity, the different algorithms all have relatively similar performance. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  11. Evaluation of a New Surgical Technique for Closing Oroantral Fistula Using Auto-transplanted Upper Third Molar: A 1-Year Follow-Up Study.

    PubMed

    Assad, Mounzer; Alkhaled, Maysaa; Alhajj, Mohammed N

    2018-03-01

    Oroantral fistula (OAF) is considered a frequent complication in dental practice. Many surgical techniques/methods have been proposed to close it. The aim of this study was to evaluate the auto-transplantation of upper third molar for closing OAF. Twenty patients participated in this study aged between 20 and 40 years old. The OAF was closed by auto-transplantation of upper third molar placed directly in the socket of the extracted tooth. Results were evaluated clinically and radiographically through the period of observation which lasted for 1 year. Final results showed that the success rate of closing OAF was 95% while the success rate of upper third molar auto-transplantation was 90%. This technique is simple, applicable, provides immediate replacement of the missing tooth, and does not require complicated instruments or procedures.

  12. An Auto-management Thesis Program WebMIS Based on Workflow

    NASA Astrophysics Data System (ADS)

    Chang, Li; Jie, Shi; Weibo, Zhong

    An auto-management WebMIS based on workflow for bachelor thesis program is given in this paper. A module used for workflow dispatching is designed and realized using MySQL and J2EE according to the work principle of workflow engine. The module can automatively dispatch the workflow according to the date of system, login information and the work status of the user. The WebMIS changes the management from handwork to computer-work which not only standardizes the thesis program but also keeps the data and documents clean and consistent.

  13. Bilingual Vocational Training Program. Auto Body Repair. Module 2.0: Tools and Equipment.

    ERIC Educational Resources Information Center

    Northern New Mexico Community Coll., El Rito.

    This module on tools and equipment is the second of four (CE 028 303-306) in the auto body repair course of a bilingual vocational training program. The course is designed to furnish theoretical and laboratory experience in welding, metal straightening, metal finishing, painting, and use of power and hand tools. Module objectives are for students…

  14. Bilingual Skills Training Program. Auto Body Repair. Module 3.0: Basic Metal Repair.

    ERIC Educational Resources Information Center

    Northern New Mexico Community Coll., El Rito.

    This module on basic metal repair is the third of four (CE 028 303-306) in the auto body repair course of a bilingual vocational training program. The course is designed to furnish theoretical and laboratory experience in welding, metal straightening, metal finishing, painting, and use of power and hand tools. Module objectives are for students to…

  15. Drought Patterns Forecasting using an Auto-Regressive Logistic Model

    NASA Astrophysics Data System (ADS)

    del Jesus, M.; Sheffield, J.; Méndez Incera, F. J.; Losada, I. J.; Espejo, A.

    2014-12-01

    Drought is characterized by a water deficit that may manifest across a large range of spatial and temporal scales. Drought may create important socio-economic consequences, many times of catastrophic dimensions. A quantifiable definition of drought is elusive because depending on its impacts, consequences and generation mechanism, different water deficit periods may be identified as a drought by virtue of some definitions but not by others. Droughts are linked to the water cycle and, although a climate change signal may not have emerged yet, they are also intimately linked to climate.In this work we develop an auto-regressive logistic model for drought prediction at different temporal scales that makes use of a spatially explicit framework. Our model allows to include covariates, continuous or categorical, to improve the performance of the auto-regressive component.Our approach makes use of dimensionality reduction (principal component analysis) and classification techniques (K-Means and maximum dissimilarity) to simplify the representation of complex climatic patterns, such as sea surface temperature (SST) and sea level pressure (SLP), while including information on their spatial structure, i.e. considering their spatial patterns. This procedure allows us to include in the analysis multivariate representation of complex climatic phenomena, as the El Niño-Southern Oscillation. We also explore the impact of other climate-related variables such as sun spots. The model allows to quantify the uncertainty of the forecasts and can be easily adapted to make predictions under future climatic scenarios. The framework herein presented may be extended to other applications such as flash flood analysis, or risk assessment of natural hazards.

  16. Comparative and International Learning from Vanuatu Research Moratoria: A Plurilevel, Plurilocal Researcher's Auto-Ethnography

    ERIC Educational Resources Information Center

    McCormick, Alexandra

    2017-01-01

    In this article, I offer a reflexive auto-ethnography to revisit questions about knowledge and research practices in international contexts, influenced differently by aspects of globalization. Specifically, I position my experience of the Vanuatu research moratorium on "foreign" researchers of 2013/2014 as a lynchpin to analyse and…

  17. Timing the transfer of responsibilities for anaphylaxis recognition and use of an epinephrine auto-injector from adults to children and teenagers: pediatric allergists' perspective.

    PubMed

    Simons, Elinor; Sicherer, Scott H; Simons, F Estelle R

    2012-05-01

    The optimal time for transferring responsibilities for anaphylaxis recognition and epinephrine auto-injector use from adults to children and teenagers has not yet been defined. To determine whether pediatric allergists have age-specific goals for beginning to transfer responsibilities for anaphylaxis recognition and epinephrine auto-injector use from parents and caregivers to children and teenagers at risk of anaphylaxis in the community. Members of the American Academy of Pediatrics Section on Allergy and Immunology (AAP-SOAI) were surveyed about when they typically begin to transfer these responsibilities from adults to children and teenagers. Eighty-eight allergists responded to the survey, 97.7% of whom provided service to children and teenagers with food allergies. Few allergists expected to begin transferring responsibilities for anaphylaxis recognition and epinephrine auto-injector use to children younger than 9 to 11 years. By the time their patients reached age 12 to 14 years, however, most allergists expected them to be able to describe some anaphylaxis symptoms (95.4%), demonstrate how to use an epinephrine auto-injector trainer (93.1%), begin carrying self-injectable epinephrine (88.2%), recognize the need for epinephrine (88.1%), learn to self-inject epinephrine (84.5%), and be able to self-inject epinephrine (78.6%) (cumulative data). The allergists rated the following as "very important" readiness factors for beginning to transfer responsibilities: medical history, developmental level, and ability to demonstrate auto-injector technique. Most pediatric allergists expected that by age 12 to 14 years, their patients should begin to share responsibilities with adults for anaphylaxis recognition and epinephrine auto-injector use; however, they individualized the timing based on assessment of patient readiness factors. Copyright © 2012 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  18. Development of a generic auto-calibration package for regional ecological modeling and application in the Central Plains of the United States

    USGS Publications Warehouse

    Wu, Yiping; Liu, Shuguang; Li, Zhengpeng; Dahal, Devendra; Young, Claudia J.; Schmidt, Gail L.; Liu, Jinxun; Davis, Brian; Sohl, Terry L.; Werner, Jeremy M.; Oeding, Jennifer

    2014-01-01

    Process-oriented ecological models are frequently used for predicting potential impacts of global changes such as climate and land-cover changes, which can be useful for policy making. It is critical but challenging to automatically derive optimal parameter values at different scales, especially at regional scale, and validate the model performance. In this study, we developed an automatic calibration (auto-calibration) function for a well-established biogeochemical model—the General Ensemble Biogeochemical Modeling System (GEMS)-Erosion Deposition Carbon Model (EDCM)—using data assimilation technique: the Shuffled Complex Evolution algorithm and a model-inversion R package—Flexible Modeling Environment (FME). The new functionality can support multi-parameter and multi-objective auto-calibration of EDCM at the both pixel and regional levels. We also developed a post-processing procedure for GEMS to provide options to save the pixel-based or aggregated county-land cover specific parameter values for subsequent simulations. In our case study, we successfully applied the updated model (EDCM-Auto) for a single crop pixel with a corn–wheat rotation and a large ecological region (Level II)—Central USA Plains. The evaluation results indicate that EDCM-Auto is applicable at multiple scales and is capable to handle land cover changes (e.g., crop rotations). The model also performs well in capturing the spatial pattern of grain yield production for crops and net primary production (NPP) for other ecosystems across the region, which is a good example for implementing calibration and validation of ecological models with readily available survey data (grain yield) and remote sensing data (NPP) at regional and national levels. The developed platform for auto-calibration can be readily expanded to incorporate other model inversion algorithms and potential R packages, and also be applied to other ecological models.

  19. Auto-ignition of hydrocarbons behind reflected shock waves.

    NASA Technical Reports Server (NTRS)

    Vermeer, D. J.; Meyer, J. W.; Oppenheim, A. K.

    1972-01-01

    The paper reports on the study of auto-ignition of hydrocarbon-oxygen mixtures behind reflected shock waves. Because of their bearing on the problem of knock in internal combustion engines, n-heptane and iso-octane were chosen as the combustible species. Their stoichiometric mixtures with oxygen had to be diluted with 70% argon to reduce the influence of the boundary layer. Photographic records demonstrated the existence of two different modes of ignition, as has been previously established for the hydrogen-oxygen system. The pressure-temperature limits between these regions of mild and strong ignition were determined. From the same experimental tests, induction time data were obtained over the pressure range of 1-4 atm and the temperature interval of 1200-1700 K.

  20. Computer-Controlled System for Plasma Ion Energy Auto-Analyzer

    NASA Astrophysics Data System (ADS)

    Wu, Xian-qiu; Chen, Jun-fang; Jiang, Zhen-mei; Zhong, Qing-hua; Xiong, Yu-ying; Wu, Kai-hua

    2003-02-01

    A computer-controlled system for plasma ion energy auto-analyzer was technically studied for rapid and online measurement of plasma ion energy distribution. The system intelligently controls all the equipments via a RS-232 port, a printer port and a home-built circuit. The software designed by Lab VIEW G language automatically fulfils all of the tasks such as system initializing, adjustment of scanning-voltage, measurement of weak-current, data processing, graphic export, etc. By using the system, a few minutes are taken to acquire the whole ion energy distribution, which rapidly provides important parameters of plasma process techniques based on semiconductor devices and microelectronics.