Sample records for ac plasma display

  1. Addressing Theory and Performance Enhancements for the Independent Sustain and Address AC Plasma Display

    NASA Astrophysics Data System (ADS)

    Warren, Kevin Wilson

    The Independent Sustain and Address (ISA) AC plasma panel is a flat, flicker-free, gas discharge type of display device. This display technology promises to reduce both the cost of manufacturing and operation of AC plasma displays. The ISA technology uses a vastly different mechanism to change the state of the display pixels than the standard AC plasma technology. This addressing mechanism is an exploitation of some of the natural characteristics associated with the plasma that can form during strong gas discharges. This thesis presents detailed data from experiments that were designed to evaluate and test the effectiveness of this mechanism. Through these experiments, the theory that the addressing methodology is based upon is developed and evaluated. These experiments show that the address margin windows for this technology are very large, minimally two to three times larger than the address margins for the standard XY AC plasma addressing techniques. New capabilities are also described, such as global brightness control for the ISA technology and a technique for increasing the addressing rate. These advances were designed into working prototypes and transferred to industry where there are currently commercial products available based upon these advances. A technique for implementing gray scale using some of these advances is also proposed.

  2. Research and Development of Large Area Color AC Plasma Displays

    NASA Astrophysics Data System (ADS)

    Shinoda, Tsutae

    1998-10-01

    Plasma display is essentially a gas discharge device using discharges in small cavities about 0. 1 m. The color plasma displays utilize the visible light from phosphors excited by the ultra-violet by discharge in contrast to monochrome plasma displays utilizing visible light directly from gas discharges. At the early stage of the color plasma display development, the degradation of the phosphors and unstable operating voltage prevented to realize a practical color plasma display. The introduction of the three-electrode surface-discharge technology opened the way to solve the problems. Two key technologies of a simple panel structure with a stripe rib and phosphor alignment and a full color image driving method with an address-and-display-period-separated sub-field method have realized practically available full color plasma displays. A full color plasma display has been firstly developed in 1992 with a 21-in.-diagonal PDP and then a 42-in.-diagonal PDP in 1995 Currently a 50-in.-diagonal color plasma display has been developed. The large area color plasma displays have already been put into the market and are creating new markets, such as a wall hanging TV and multimedia displays for advertisement, information, etc. This paper will show the history of the surface-discharge color plasma display technologies and current status of the color plasma display.

  3. A Cost-Effective Energy-Recovering Sustain Driving Circuit for ac Plasma Display Panels

    NASA Astrophysics Data System (ADS)

    Lim, Jae Kwang; Tae, Heung-Sik; Choi, Byungcho; Kim, Seok Gi

    A new sustain driving circuit, featuring an energy-recovering function with simple structure and minimal component count, is proposed as a cost-effective solution for driving plasma display panels during the sustaining period. Compared with existing solutions, the proposed circuit reduces the number of semiconductor switches and reactive circuit components without compromising the circuit performance and gas-discharging characteristics. In addition, the proposed circuit utilizes the harness wire as an inductive circuit component, thereby further simplifying the circuit structure. The performance of the proposed circuit is confirmed with a 42-inch plasma display panel.

  4. High voltage AC plasma torches with long electric arcs for plasma-chemical applications

    NASA Astrophysics Data System (ADS)

    Surov, A. V.; Popov, S. D.; Serba, E. O.; Pavlov, A. V.; Nakonechny, Gh V.; Spodobin, V. A.; Nikonov, A. V.; Subbotin, D. I.; Borovskoy, A. M.

    2017-04-01

    Powerful AC plasma torches are in demand for a number of advanced plasma chemical applications, they can provide high enthalpy of the working gas. IEE RAS specialists have developed a number of models of stationary thermal plasma torches for continuous operation on air with the power from 5 to 500 kW, and on mixture of H2O, CO2 and CH4 up to 150 kW. AC plasma torches were tested on the pilot plasmachemical installations. Powerful AC plasma torch with hollow electrodes and the gas vortex stabilization of arc in cylindrical channels and its operation characteristics are presented. Lifetime of its continuous operation on air is 2000 hours and thermal efficiency is about 92%, the electric arc length between two electrodes of the plasma torch exceeds 2 m.

  5. State-of-the-art for large area high resolution gray scale and full color AC plasma flat panel displays

    NASA Technical Reports Server (NTRS)

    Stoller, Ray A.; Wedding, Donald K.; Friedman, Peter S.

    1993-01-01

    A development status evaluation is presented for gas plasma display technology, noting how tradeoffs among the parameters of size, resolution, speed, portability, color, and image quality can yield cost-effective solutions for medical imaging, CAD, teleconferencing, multimedia, and both civil and military applications. Attention is given to plasma-based large-area displays' suitability for radar, sonar, and IR, due to their lack of EM susceptibility. Both monochrome and color displays are available.

  6. Plasma Display at the Liberty Science Center

    NASA Astrophysics Data System (ADS)

    Bruder, Dan; Gilligan, Nick; Tarman, Lisa; Ferris, Pamella; Morgan, James; Delooper, John; Zwicker, Andrew

    2009-11-01

    The Liberty Science Center (LSC) is the largest (300,000 sq. ft.) education resource in the New Jersey -- New York City region. PPPL in collaboration with the LSC has had a display at the center since 2007 More than 1.5 million visitors have come to the museum since the plasma display has been introduced. The plasma display has had significant use during that time frame. During the summer of 2009 a redesigned plasma exhibit was created by a student teacher-team using the lessons learned from the existing exhibit. The display includes a DC glow discharge tube with a permanent external magnet allowing visitors to manipulate the plasma and see how plasma can be used for fusion research. The goal of the display is to allow an individual to see a plasma and understand the potential benefits of fusion energy.

  7. The Feasibility of Applying AC Driven Low-Temperature Plasma for Multi-Cycle Detonation Initiation

    NASA Astrophysics Data System (ADS)

    Zheng, Dianfeng

    2016-11-01

    Ignition is a key system in pulse detonation engines (PDE). As advanced ignition methods, nanosecond pulse discharge low-temperature plasma ignition is used in some combustion systems, and continuous alternating current (AC) driven low-temperature plasma using dielectric barrier discharge (DBD) is used for the combustion assistant. However, continuous AC driven plasmas cannot be used for ignition in pulse detonation engines. In this paper, experimental and numerical studies of pneumatic valve PDE using an AC driven low-temperature plasma igniter were described. The pneumatic valve was jointly designed with the low-temperature plasma igniter, and the numerical simulation of the cold-state flow field in the pneumatic valve showed that a complex flow in the discharge area, along with low speed, was beneficial for successful ignition. In the experiments ethylene was used as the fuel and air as oxidizing agent, ignition by an AC driven low-temperature plasma achieved multi-cycle intermittent detonation combustion on a PDE, the working frequency of the PDE reached 15 Hz and the peak pressure of the detonation wave was approximately 2.0 MPa. The experimental verifications of the feasibility in PDE ignition expanded the application field of AC driven low-temperature plasma. supported by National Natural Science Foundation of China (No. 51176001)

  8. Large Arrays of Microcavity Plasma Devices for Active Displays and Backlighting

    NASA Astrophysics Data System (ADS)

    Eden, J. Gary; Park, Sung-Jin; Ostrom, Nels P.; Chen, Kuo-Feng; Kim, Kwang Soo

    2005-09-01

    Developments of the past several years in the technology of microcavity plasma devices having characteristic dimensions of 10-100 µm suggests their applicability to the next generation of active and passive displays. Two examples of device structures that are well suited for economically manufactured arrays of large active area are presented. Arrays as large as 500 x 500 (2.5 ṡ 105) pixels of Si inverted pyramid microplasma devices, with emitting apertures of 50 x 50 µm2 and designed for AC or bipolar excitation, have been designed and operated successfully in the rare gases at pressures up to and beyond one atmosphere. Multilayer Al/nanostructured Al2O3 microplasma devices having 100-300 µm diam. cylindrical microcavities are robust and operate in the abnormal glow mode for rare gas or Ar/2-5% N2 mixture pressures of 500-700 torr. Grown by a wet chemical process, the nanoporous Al2O3 dielectric yields a lightweight, flexible structure that produces intense visible or ultraviolet emission when driven by sinusoidal AC or bipolar voltage waveforms.

  9. Water treatment by the AC gliding arc air plasma

    NASA Astrophysics Data System (ADS)

    Gharagozalian, Mehrnaz; Dorranian, Davoud; Ghoranneviss, Mahmood

    2017-09-01

    In this study, the effects of gliding arc (G Arc) plasma system on the treatment of water have been investigated experimentally. An AC power supply of 15 kV potential difference at 50 Hz frequency was employed to generate plasma. Plasma density and temperature were measured using spectroscopic method. The water was contaminated with staphylococcus aureus (Gram-positive) and salmonella bacteria (Gram-negative), and Penicillium (mold fungus) individually. pH, hydrogen peroxide, and nitride contents of treated water were measured after plasma treatment. Decontamination of treated water was determined using colony counting method. Results indicate that G Arc plasma is a powerful and green tool to decontaminate water without producing any byproducts.

  10. A Plasma Display Terminal.

    ERIC Educational Resources Information Center

    Stifle, Jack

    A graphics terminal designed for use as a remote computer input/output terminal is described. Although the terminal is intended for use in teaching applications, it has several features which make it useful in many other computer terminal applications. These features include: a 10-inch square plasma display panel, permanent storage of information…

  11. Atomic oxygen behavior at downstream of AC excited atmospheric pressure He plasma jet

    NASA Astrophysics Data System (ADS)

    Takeda, Keigo; Ishikawa, Kenji; Tanaka, Hiromasa; Sekine, Makoto; Hori, Masaru

    2016-09-01

    Applications of atmospheric pressure plasma jets (APPJ) have been investigated in the plasma medical fields such as cancer therapy, blood coagulation, etc. Reactive species generated by the plasma jet interacts with the biological surface. Therefore, the issue attracts much attentions to investigate the plasma effects on targets. In our group, a spot-size AC excited He APPJ have been used for the plasma medicine. From diagnostics of the APPJ using optical emission spectroscopy, the gas temperature and the electron density was estimated to be 299 K and 3.4 ×1015 cm-3. The AC excited He APPJ which affords high density plasma at room temperature is considered to be a powerful tool for the medical applications. In this study, by using vacuum ultraviolet absorption spectroscopy, the density of atomic oxygen on a floating copper as a target irradiated by the He APPJ was measured as a function of the distance between the plasma source and the copper wire. The measured density became a maximum value around 8 ×1013 cm-3 at 12 mm distance, and then decreased over the distance. It is considered that the behavior was due to the changes in the plasma density on the copper wire and influence of ambient air.

  12. AC Glow Discharge Plasma in N2O

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yousif, F. B.; Martinez, H.; Robledo-Martinez, A.

    2006-12-04

    This paper considers the optical and electrical characterization of AC glow discharge plasma in the abnormal glow mode used for optical emission spectroscopy. The total discharge current and applied voltage are measured using conventional techniques. The electrical characteristics of the planer-cathode glow discharge confirmed that the plasma is operating at abnormal discharge mode characterized by the increases in the operating voltage as the current was raised under given pressure. Optical emission spectroscopy was used to determine the main emission lines of the glow discharge plasma of N2O at pressures between 0.5 and 4.0 Torr. It shows that the discharge emissionmore » range is mainly within 300-400 nm. The emission lines correspond to NO, O2, and O{sub 2}{sup +} are the dominant lines in the glow discharge plasma in the present study. Intensity of the emission lines show linear increase with the discharge current up to 0.4 A followed by saturation at higher currents. No emission lines were observed in this work corresponding to atomic oxygen or nitrogen.« less

  13. Diagnostics of AC excited Atmospheric Pressure Plasma Jet with He for Biomedical Applications

    NASA Astrophysics Data System (ADS)

    Hori, Masaru; Takeda, Keigo; Kumakura, Takumi; Ishikawa, Kenji; Tanaka, Hiromasa; Kondo, Hiroki; Sekine, Makoto; Nakai, Yoshihiro

    2014-10-01

    Atmospheric pressure plasma jets (APPJ) are frequently used for biomedical applications. Reactive species generated by the APPJ play important roles for treatments of biomedical samples. Therefore, high density APPJ sources are required to realize the high performance. Our group has developed AC excited Ar APPJ with electron density as high as 1015 cm-3, and realized the selective killing of cancer cells and the inactivate spores of Penicillium digitatum. Recently, a new spot-size AC excited APPJ with He gas have been developed. In this study, the He APPJ was characterized by using spectroscopy. The plasma was discharged at a He flow rate of 5 slm and a discharge voltage of AC 9 kV. Gas temperature and electron density of the APPJ were measured by optical emission spectroscopy. From theoretical fitting of 2nd positive system of N2 emission (380.4 nm) and Stark broadening of Balmer β line of H atom (486.1 nm), the gas temperature and the electron density was estimated to be 299 K and 3.4. × 1015 cm-3. The AC excited He APPJ has a potential to realize high density with room temperature and become a very powerful tool for biomedical applications.

  14. Investigation of the AC Plasma Torch Working Conditions for the Plasma Chemical Applications

    NASA Astrophysics Data System (ADS)

    Safronov, A. A.; Vasilieva, O. B.; Dudnik, J. D.; E Kuznetsov, V.; Shiryaev, V. N.; Subbotin, D. I.; Pavlov, A. V.

    2017-04-01

    The presented design and parameters of a three-phase AC plasma torch with the power up to 500 kW, flow rate of air 30-50 g/s (temperature up to 5000 K) could be used in different plasma chemical processes. Range of measured plasma temperature is 3500-5000 K. The paper presents investigations of the plasma torch operation modes for its application in plasma chemical technologies. Plasma chemical technologies for various purposes (processing, destruction of various wastes, including technological and hazardous waste, conversion or production of chemicals to obtain nanoscale materials, etc.) are very promising in terms of the process efficiency. Their industrial use is difficult due to the lack of inexpensive and reliable plasma torches providing the desired level of temperature, enthalpy of the working gas and other necessary conditions for the process. This problem can be solved using a considered design of a three-phase alternating current plasma torch with power of 150-500 kW with working gas flow rate of 30-50 g/s with mass average temperature up to 5000K on the basis of which an industrial plasma chemical plant can be created. The basis of the plasma torch operation is a railgun effect that is the principle of arc movement in the field of its own current field. Thanks to single supply of power to the arc, arcs forming in the discharge chamber of the plasma torch move along the electrodes under the action of electrodynamic forces resulting from the interaction of the arc current with its own magnetic field. Under the condition of the three-phase supply voltage, arc transits from the electrode to the electrode with change in the anodic and cathodic phases with frequency of 300 Hz. A special feature of this design is the ability to organize the movement of the arc attachment along the electrode, thus ensuring an even distribution of the thermal load and thus achieve long time of continuous operation of the plasma torch. The parameters of the plasma jet of the

  15. HOT PLASMA FROM SOLAR ACTIVE REGION CORES: A TEST OF AC AND DC CORONAL HEATING MODELS?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmelz, J. T.; Christian, G. M.; Dhaliwal, R. S.

    2015-06-20

    Direct current (DC) models of solar coronal heating invoke magnetic reconnection to convert magnetic free energy into heat, whereas alternating current (AC) models invoke wave dissipation. In both cases the energy is supplied by photospheric footpoint motions. For a given footpoint velocity amplitude, DC models predict lower average heating rates but greater temperature variability when compared to AC models. Therefore, evidence of hot plasma (T > 5 MK) in the cores of active regions could be one of the ways for current observations to distinguish between AC and DC models. We have analyzed data from the X-Ray Telescope (XRT) andmore » the Atmospheric Imaging Assembly for 12 quiescent active region cores, all of which were observed in the XRT Be-thick channel. We did Differential Emission Measure (DEM) analysis and achieved good fits for each data set. We then artificially truncated the hot plasma of the DEM model at 5 MK and examined the resulting fits to the data. For some regions in our sample, the XRT intensities continued to be well-matched by the DEM predictions, even without the hot plasma. This truncation, however, resulted in unacceptable fits for the other regions. This result indicates that the hot plasma is present in these regions, even if the precise DEM distribution cannot be determined with the data available. We conclude that reconnection may be heating the hot plasma component of these active regions.« less

  16. New perspectives on the dynamics of AC and DC plasma arcs exposed to cross-fields

    NASA Astrophysics Data System (ADS)

    Abdo, Youssef; Rohani, Vandad; Cauneau, François; Fulcheri, Laurent

    2017-02-01

    Interactions between an arc and external fields are crucially important for the design and the optimization of modern plasma torches. Multiple studies have been conducted to help better understand the behavior of DC and AC current arcs exposed to external and ‘self-induced’ magnetic fields, but the theoretical foundations remain very poorly explored. An analytical investigation has therefore been carried out in order to study the general behavior of DC and AC arcs under the effect of random cross-fields. A simple differential equation describing the general behavior of a planar DC or AC arc has been obtained. Several dimensionless numbers that depend primarily on arc and field parameters and the main arc characteristics (temperature, electric field strength) have also been determined. Their magnitude indicates the general tendency pattern of the arc evolution. The analytical results for many case studies have been validated using an MHD numerical model. The main purpose of this investigation was deriving a practical analytical model for the electric arc, rendering possible its stabilization and control, and the enhancement of the plasma torch power.

  17. Simulation of photons from plasmas for the applications to display devices

    NASA Astrophysics Data System (ADS)

    Lee, Hae June; Yoon, Hyun Jin; Lee, Jae Koo

    2007-07-01

    Numerical modeling of the photon transport of the ultraviolet (UV) and the visible lights are presented for plasma based display devices. The transport of UV lights which undergo resonance trapping by ground state atoms is solved by using the Holstein equation. After the UV lights are transformed to visible lights at the phosphor surfaces, the visible lights experience complicated traces inside the cell and finally are emitted toward the viewing window after having some power loss within the cell. A three-dimensional ray trace of the visible lights is calculated with a radiosity model. These simulations for the photons strengthen plasma discharge modeling for the application to display devices.

  18. Impairment of liver synthetic function and the production of plasma proteins in primary breast cancer patients on doxorubicincyclophosphamide (AC) protocol.

    PubMed

    Saleem, Zikria; Ahmad, Mobasher; Hashmi, Furqan Khurshid; Saeed, Hamid; Aziz, Muhammad Tahir

    2016-09-01

    Doxorubicin and Cyclophosphamide (AC protocol) combination is usually considered as a first line therapy in newly diagnosed breast cancer patients. Thus, a retrospective observational study was conducted to monitor the effect of AC protocol on liver synthetic functions and production of plasma proteins in breast cancer patients, reporting to specialized cancer care hospital of Lahore, Pakistan. A total of 75 patients (n=75) on AC protocol with breast cancer were observed in this study. The patient data including age, gender, body surface area, dosage, disease status and laboratory biochemical values were recorded by reviewing historical treatment records. Pre-treatment values were taken as baseline values for albumin, globulin, blood urea nitrogen (BUN), albumin/globulin (A/G) ratio and total proteins. The baseline values were compared after each cycle of by applying ANOVA using statistical tool SPSS® version 21. The plasma levels of blood urea nitrogen (BUN), total protein and globulin dropped significantly (p<0.05) in patients of all age groups. However, the albumin levels were not significantly changed (p>0.05). The A/G ratio level increased (p<0.05) as a result of reduction in globulin levels. Significant changes in plasma protein levels were observed in the elderly patients (50 to 65 years) than patients between 20 to 50 years of age. AC protocol impairs liver synthetic functions as observed by decreased blood urea nitrogen (BUN) and plasma protein levels.

  19. Sterilization of Long Tube Inner Surface Using Oxygen and Water Vapor Plasmas Produced by AC HV Discharge

    NASA Astrophysics Data System (ADS)

    Kitazaki, Satoshi; Hayashi, Nobuya

    2009-10-01

    Oxygen and water vapor plasmas inside a narrow long tube were produced using an AC HV glow discharge at low pressure in order to sterilize the inner surface of a tube. In order to produce plasma inside a narrow tube, an AC high voltage was adopted. The material of the tube used in this experiment was silicon rubber. The length and diameter of the tubes ranged from 300 to 1,000 mm and from 1 to 4 mm, respectively. The tube was placed in a stainless steel vacuum chamber and was evacuated to 10 Pa using a rotary pump. The material gas for plasma and radical productions was pure oxygen or water vapor, which was introduced to the chamber from a gas cylinder or water reservoir. Light emission spectral lines of oxygen and OH radicals were observed at 777 nm and 306 nm, respectively. The chemical indicator was inserted into the tube and turned to a yellowish color (from the original red) after a treatment, which indicates the generation of sufficient oxygen on OH radicals for sterilization. A tube with the length of 500 mm and diameter of 4 mm is sterilized using oxygen plasma by 10 minutes treatment. Also a tube with the length of 300 mm and diameter of 2 mm is sterilized using water vapor plasma by 5 minutes treatment.

  20. Leaching assessments of toxic metals in waste plasma display panel glass.

    PubMed

    Chen, Mengjun; Jiang, Pengfei; Chen, Haiyan; Ogunseitan, Oladele A; Li, Yungui

    2015-06-01

    The plasma display panel (PDP) is rapidly becoming obsolete, contributing in large amounts to the electronic waste stream. In order to assess the potential for environmental pollution due to hazardous metals leached from PDP glass, standardized leaching procedures, chemical speciation assessments, and bioavailability tests were conducted. According to the Toxicity Characteristic Leaching Procedure (TCLP), arsenic in back glass was present at 4.46 ± 0.22 mg/L, close to its regulation limit of 5 mg/L. Zn is not available in the TCLP, but its TCLP leaching concentration in back glass is 102.96 ± 5.34 mg/L. This is because more than 90% of Zn is in the soluble and exchangeable and carbonate fraction. We did not detect significant levels of Ag, Ba, or Cu in the TCLP leachate, and the main fraction of Ag and Ba is residual, more than 95%, while the fraction distribution of Cu changes SEP by SEP. Ethylenediamine tetraacetic acid (EDTA)- and diethylenetriamine pentaacetic acid (DTPA)-extractable Ag, As, Ba, Cu, Zn, and Ni indicate a lower biohazards potential. These results show that, according to the EPA regulations, PDP glass may not be classified as hazardous waste because none of the metals exceeded their thresholds in PDP leachate. However, the concentrations of As and Zn should be lowered in the manufacturing process and finished product to avoid potential pollution problems. The plasma display panel is rapidly becoming obsolete because of the liquid crystal display. In this study, the leachability of heavy metals contained in the waste plasma display panel glass was first examined by standardized leaching tests, typical chemical speciation assessments, and bioavailability tests, providing fundamental data for waste PDP glass recovery, recycling, and reuse.

  1. Needle-array to Plate DBD Plasma Using Sine AC and Nanosecond Pulse Excitations for Purpose of Improving Indoor Air Quality

    PubMed Central

    Zhang, Li; Yang, Dezheng; Wang, Wenchun; Wang, Sen; Yuan, Hao; Zhao, Zilu; Sang, Chaofeng; Jia, Li

    2016-01-01

    In this study, needle-array to plate electrode configuration was employed to generate an atmospheric air diffuse discharge using both nanosecond pulse and sine AC voltage as excitation voltage for the purpose of improving indoor air quality. Different types of voltage sources and electrode configurations are employed to optimize electrical field distribution and improve discharge stability. Discharge images, electrical characteristics, optical emission spectra, and plasma gas temperatures in both sine AC discharge and nanosecond pulse discharge were compared and the discharge stability during long operating time were discussed. Compared with the discharge excited by sine AC voltage, the nanosecond pulsed discharge is more homogenous and stable, besides, the plasma gas temperature of nanosecond pulse discharge is much lower. Using packed-bed structure, where γ- Al2O3 pellets are filled in the electrode gap, has obvious efficacy in the production of homogenous discharge. Furthermore, both sine AC discharge and nanosecond pulse discharge were used for removing formaldehyde from flowing air. It shows that nanosecond pulse discharge has a significant advantage in energy cost. And the main physiochemical processes for the generation of active species and the degradation of formaldehyde were discussed. PMID:27125663

  2. Penning Effects in High-Pressure Discharge of the Plasma Display Panel

    NASA Astrophysics Data System (ADS)

    Kim, S. S.; Choi, E. H.; Uhm, H. S.

    2001-10-01

    The plasma display panel is operated with high-pressure gas, for which the breakdown voltage reduction may be accomplished by mixing a small amount of xenon with neon gas. The UV light emitted from xenon discharge plasma is converted into fluorescent light, providing TV images. A recent theoretical calculation indicates that the breakdown voltage is significantly reduced for the mixed gas due to collisional frequency decrease. It is easy to ionize xenon atoms with low ionization energy. The electrons can also easily get their kinetic energy in neon gas mixed with xenon atoms, thereby reducing their collisional cross section and ionizing xenon atoms. However, previous study indicates that the breakdown voltage can be further reduced by the Penning effects, which has been mostly studied in a low pressure discharge. Influence of the Penning effects on the high-pressure discharge in a neon-xenon mixed gas is investigated in connection with applications to the plasma display panel. A theoretical model for high-pressure discharge is developed. It is shown that the breakdown voltage is reduced by 20 percent at the xenon mole fraction of 0.015, which agree remarkably well with experimental data.

  3. Plasma antennas driven by 5–20 kHz AC power supply

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Jiansen, E-mail: 67093058@qq.com; Chen, Yuli; Sun, Yang

    2015-12-15

    The experiments described in this work were performed with the aim of introducing a new plasma antenna that was excited by a 5–20 kHz alternating current (AC) power supply, where the antenna was transformed into a U-shape. The results show that the impedance, voltage standing-wave ratio (VSWR), radiation pattern and gain characteristics of the antenna can be controlled rapidly by varying not only the discharge power, but also by varying the discharge frequency in the range from 5 to 20 kHz. When the discharge frequency is adjusted from 10 to 12 kHz, the gain is higher within a relatively broadmore » frequency band and the switch-on time is less than 1 ms when the discharge power is less than 5 W, meaning that the plasma antenna can be turned on and off rapidly.« less

  4. Plasma characteristics of argon glow discharge produced by AC power supply operating at low frequencies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kongpiboolkid, Watcharapon; Mongkolnavin, Rattachat; Plasma Technology and Nuclear Fusion Research Unit, Chulalongkorn University, Bangkok

    2015-04-24

    Non-thermal properties of Argon glow discharge operating with various operating pressures were measured and presented in this work. The Argon plasma is produced by a parallel conducting electrodes coupling with a high voltage AC power supply. The power supply can generate high AC voltage at various frequencies. The frequencies for the operation are in the range of a few kHz. The system is capable of generating electric field between the two metal electrodes discharge system. The characteristics of plasma produced were measured by optical emission spectroscopy (OES) technique where electron temperature (T{sub e}) and electron number density (n{sub e}) canmore » be determined by line intensity ratio method. The value of electron number density was then determined from the Saha-Eggert equation. Our results show that the electron number density of the discharge obtained is of the order of 10{sup −17} − 10{sup −18} m{sup −3} where the electron temperature is between 1.00−2.00 eV for various operating frequencies used which are in good agreement with similar results published earlier.« less

  5. Comparing Ns-DBD vs Ac-DBD plasma actuation mechanisms on a NACA 0012 airfoil

    NASA Astrophysics Data System (ADS)

    Singh, Ashish; Durasiewicz, Claudia; Little, Jesse

    2017-11-01

    A NACA 0012 airfoil is used to study ns-DBD and ac-DBD plasma actuators at a Reynolds number of 740,000 (U∞=40 m/s). Ns-DBD plasma actuators are hypothesized to work on the principle of joule heating whereas ac-DBD actuators add momentum to the flow. Short duration forcing at a time scale much smaller than the convective time based on model chord is employed to study the control mechanism and flow field response. 2-D PIV carried out over a convective time range of 0-10 is used to study the flow structure. The results show the breakup of shear layer vorticity at the point of actuation followed by reattachment to the suction side of the airfoil and finally stall again. These events are very similar between the two actuators and indicate a similar flow response to different perturbation types. The pulse energies are varied and the response shows little change. The results are compared to other transitory separation control studies using more conventional actuators. The detailed study of these two control mechanisms with the separated flow over an airfoil helps to shed light on the evolution of the flow control process. Additional results on a simplified model problem (low speed mixing layer) are included to provide context. Supported by U.S. Army Research Office (W911NF-14-1-0662).

  6. Research Program on Factors Affecting the Brightness of AC Plasma Panels.

    DTIC Science & Technology

    1983-06-01

    representing the second excited electronic con - figuration in neon. In an effort to devise means to improve the brightness and/or efficiency of neon filled...obtained from several panels was found to be very good (Ref. 6), a factor providing important support for the validity of the kinetic modeling pro - cedures...pressure neon Penning mixtures for I conditions typical of plasma panel displays [II]. Their work has pro - vied valuable insight regarding the electrical

  7. Investigation of the transition of multicycle AC operation in ISTTOK under edge electrode biasing

    NASA Astrophysics Data System (ADS)

    Malaquias, A.; Henriques, R. B.; Silva, C.; Figueiredo, H.; Nedzelskiy, I. S.; Fernandes, H.; Sharma, R.; Plyusnin, V. V.

    2017-11-01

    In this paper we present recent results obtained on plasma edge electrode biasing during AC discharges. The goal is to obtain experimental evidence on a number of plasma parameters that can play a role during the AC transition on the repeatability and reproducibility of AC operation. The control of the plasma density in the quiescent phase is made just before the AC transition by means of positive edge biasing leading to a transitory improved of density (30%-40%). Gas puff experiments show that the increase of background gas pressure during discharge led to a better success of the AC transition. The experimental results indicate that the increase of density during the AC transition induced by edge biasing is followed by an electron temperature drop. The drop in electron temperature leads in most cases the formation of runaway electrons. It has been observed that the runaway population during discharge flattop depends on the interplay between gas content and plasma density and temperature. The results also confirm that the correct balance of external magnetic fields is crucial during the AC transition phase where drift electron currents are formed. The results from the heavy ion beam diagnostic show that the formation of plasma current during consecutive AC transitions is asymmetric. Numerical simulations indicate that for some particular conditions this result could be reproduced from assuming the presence of two counter-currents during AC transition.

  8. DC response of dust to low frequency AC signals

    NASA Astrophysics Data System (ADS)

    McKinlay, Michael; Konopka, Uwe; Thomas, Edward

    2017-10-01

    Macroscopic changes in the shape and equilibrium position of clouds of charged microparticles suspended in a plasma have been observed in response to low frequency AC signals. In these experiments, dusty plasmas consisting of 2-micron diameter silica microspheres suspended between an anode and cathode in an argon, DC glow discharge plasma are produced in a grounded, 6-way cross vacuum chamber. An AC signal, produced by a function generator and amplified by a bipolar op-amp, is superimposed onto the potential from the cathode. The frequencies of the applied AC signals, ranging from tens to hundreds of kHz, are comparable to the ion-neutral collision frequency; well below the ion/electron plasma frequencies, but also considerably higher than the dust plasma frequency. This presentation will detail the experimental setup, present documentation and categorization of observations of the dust response, and present an initial model of the response. This work is supported by funding from the US Dept. of Energy, Grant Number DE-SC0016330, and by the National Science Foundation, Grant Number PHY-1613087.

  9. Experimental investigation of SDBD plasma actuator driven by AC high voltage with a superimposed positive pulse bias voltage

    NASA Astrophysics Data System (ADS)

    Qi, Xiao-Hua; Yan, Hui-Jie; Yang, Liang; Hua, Yue; Ren, Chun-Sheng

    2017-08-01

    In this work, a driven voltage consisting of AC high voltage with a superimposed positive pulse bias voltage ("AC+ Positive pulse bias" voltage) is adopted to study the performance of a surface dielectric barrier discharge plasma actuator under atmospheric conditions. To compare the performance of the actuator driven by single-AC voltage and "AC+ Positive pulse bias" voltage, the actuator-induced thrust force and power consumption are measured as a function of the applied AC voltage, and the measured results indicate that the thrust force can be promoted significantly after superimposing the positive pulse bias voltage. The physical mechanism behind the thrust force changes is analyzed by measuring the optical properties, electrical characteristics, and surface potential distribution. Experimental results indicate that the glow-like discharge in the AC voltage half-cycle, next to the cycle where a bias voltage pulse has been applied, is enhanced after applying the positive pulse bias voltage, and this perhaps is the main reason for the thrust force increase. Moreover, surface potential measurement results reveal that the spatial electric field formed by the surface charge accumulation after positive pulse discharge can significantly affect the applied external electric field, and this perhaps can be responsible for the experimental phenomenon that the decrease of thrust force is delayed by pulse bias voltage action after the filament discharge occurs in the glow-like discharge region. The schlieren images further verify that the actuator-induced airflow velocity increases with the positive pulse voltage.

  10. Driving Force of Plasma Bullet in Atmospheric-Pressure Plasma

    NASA Astrophysics Data System (ADS)

    Yambe, Kiyoyuki; Masuda, Seiya; Kondo, Shoma

    2018-06-01

    When plasma is generated by applying high-voltage alternating current (AC), the driving force of the temporally and spatially varying electric field is applied to the plasma. The strength of the driving force of the plasma at each spatial position is different because the electrons constituting the atmospheric-pressure nonequilibrium (cold) plasma move at a high speed in space. If the force applied to the plasma is accelerated only by the driving force, the plasma will be accelerated infinitely. The equilibrium between the driving force and the restricting force due to the collision between the plasma and neutral particles determines the inertial force and the drift velocity of the plasma. Consequently, the drift velocity depends on the strength of the time-averaged AC electric field. The pressure applied by the AC electric field equilibrates with the plasma pressure. From the law of conservation of energy, the pressure equilibrium is maintained by varying the drift velocity of the plasma.

  11. AC Resistance measuring instrument

    DOEpatents

    Hof, Peter J.

    1983-01-01

    An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument.

  12. Hybrid flow control of a transport truck side-mirror using AC-DBD plasma actuated guide vane

    NASA Astrophysics Data System (ADS)

    Michelis, Theodoros; Kotsonis, Marios

    2014-11-01

    A wind-tunnel study is conducted towards hybrid flow control of a full-scale transport truck side-mirror (Re = 4 ×105) . The mirror is mounted on a structure that models the truck cabin. PIV measurements are performed at a range of velocities from 15 to 25 m/s and from leeward to windward angles of -5° to +5° . A slim guide vane of 6cm chord is employed along the span of the hub of the mirror for redirecting high momentum flow towards the wake region. Separation from the leading edge of the guide vane is reduced or eliminated by means of AC-DBD plasma actuator, operating at voltage of 35 kV peak-to-peak and frequency of 200 Hz. Time-averaged velocity fields are obtained at the centre of the mirror for three scenarios: a) reference case lacking any control elements; b) guide vane only and c) combination of the guide vane and the AC-DBD. The comparison of cases demonstrates that at 25 m/s windward conditions (-5°) the guide vane is capable of increasing momentum (+20%) in the wake of the mirror with additional improvement when plasma actuation is applied (+21%). In contrast, at leeward conditions (+5°) , the guide vane reduces momentum (-20%), though with actuation an increase is observed (+5%). Total recovered momentum is 25%.

  13. Vane Separation Control in a Linear Cascade with Area Expansion using AC DBD Plasma Actuators

    NASA Astrophysics Data System (ADS)

    Kleven, Christopher; Corke, Thomas

    2013-11-01

    Experiments are presented on the use of AC dielectric barrier discharge (DBD) plasma actuators to prevent flow separation on vanes in a linear cascade with area expansion. The inlet Mach number to the cascade ranged from 0.3 to 0.5, and the vane chord Reynolds numbers ranged from 0 . 9 ×106 to 1 . 5 ×106 . Three cascade designs with different amounts of area expansion, providing different degrees of adverse pressure gradients, were examined. Surface flow visualization revealed a 3-D separation bubble with strong recirculation that formed on the suction side of the vanes. The pattern agreed well with CFD simulations. Plasma actuators were placed on the suction sides of the vanes, just upstream of the flow separation location. Quantitative measurements were performed in the wakes of the vanes using a 5-hole Pitot probe. The measurements were used to determine the effect of the plasma actuator separation control on the pressure loss coefficient, and flow turning angle through the cascades. Overall, the plasma actuators separation control increased the velocity magnitude and dynamic pressure in the passage between the vanes, resulted in a more spanwise-uniform flow turning angle in the vane passage, and significantly lowered the loss coefficient compared to the baseline.

  14. AC resistance measuring instrument

    DOEpatents

    Hof, P.J.

    1983-10-04

    An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument. 8 figs.

  15. The investigation of an electric arc in the long cylindrical channel of the powerful high-voltage AC plasma torch

    NASA Astrophysics Data System (ADS)

    Rutberg, Ph G.; Popov, S. D.; Surov, A. V.; Serba, E. O.; Nakonechny, Gh V.; Spodobin, V. A.; Pavlov, A. V.; Surov, A. V.

    2012-12-01

    The comparison of conductivity obtained in experiments with calculated values is made in this paper. Powerful stationary plasma torches with prolonged period of continuous work are popular for modern plasmachemical applications. The maximum electrode lifetime with the minimum erosion can be reached while working on rather low currents. Meanwhile it is required to provide voltage arc drop for the high power achievement. Electric field strength in the arc column of the high-voltage plasma torch, using air as a plasma-forming gas, does not exceed 15 V/cm. It is possible to obtain the high voltage drop in the long arc stabilized in the channel by the intensive gas flow under given conditions. Models of high voltage plasma torches with rod electrodes with power up to 50 kW have been developed and investigated. The plasma torch arcs are burning in cylindrical channels. Present investigations are directed at studying the possibility of developing long arc plasma torches with higher power. The advantage of AC power supplies usage is the possibility of the loss minimization due to the reactive power compensation. The theoretical maximum of voltage arc drop for power supplies with inductive current limitations is about 50 % of the no-load voltage for a single-phase circuit and about 30 % for the three-phase circuit. Burning of intensively blown arcs in the long cylindrical channel using the AC power supply with 10 kV no-load voltage is experimentally investigated in the work. Voltage drops close to the maximum possible had been reached in the examined arcs in single-phase and three-phase modes. Operating parameters for single-phase mode were: current -30 A, voltage drop -5 kV, air flow rate 35 g/s; for three-phase mode: current (40-85) A, voltage drop (2.5-3.2) kV, air flow rate (60-100) g/s. Arc length in the installations exceeded 2 m.

  16. Screens and Displays.

    ERIC Educational Resources Information Center

    Edstrom, Malin

    1987-01-01

    Discusses the characteristics of different computer screen technologies including the possible harmful effects on health of cathode ray tube (CRT) terminals. CRT's are compared to other technologies including liquid crystal displays, plasma displays, electroluminiscence displays, and light emitting diodes. A chart comparing the different…

  17. Measurement of activated species generated by AC power excited non-equilibrium atmospheric pressure Ar plasma jet with air engulfment

    NASA Astrophysics Data System (ADS)

    Takeda, Keigo; Ishikawa, Kenji; Tanaka, Hiromasa; Kano, Hiroyuki; Sekine, Makoto; Hori, Masaru

    2013-09-01

    Non-equilibrium atmospheric pressure plasma jet (NEAPPJ) is very attractive tool for bio and medical applications. In the plasma treatments, samples are typically located at a far region from main discharge, and treated in open air without purge gases. Influence of air engulfment on generation of activated species in the NEAPPJ in open air is a large issue for the application. In this study, the AC excited argon NEAPPJ with the gas flow rate of 2 slm was generated under the open air condition. The densities of the grand state nitrogen monoxide (NO) and the ground state O atom generated by the NEAPPJ were measured by laser induced fluorescence spectroscopy and vacuum ultraviolet absorption spectroscopy. The length of the plasma jet was around 10 mm. Up to 10 mm, the NO density increased with increasing the distance from plasma head, and then saturated in remote region of plasma. On the other hand, the O atom density decreased from 1014 to 1013 cm-3 with increasing the distance. Especially, the amount of decrease in O atom density became the largest at the plasma edge. We will discuss the generation and loss processes of activated species generated in the NEAPPJ with the measurement results using spectroscopic methods.

  18. European display scene

    NASA Astrophysics Data System (ADS)

    Bartlett, Christopher T.

    2000-08-01

    The manufacture of Flat Panel Displays (FPDs) is dominated by Far Eastern sources, particularly in Active Matrix Liquid Crystal Displays (AMLCD) and Plasma. The United States has a very powerful capability in micro-displays. It is not well known that Europe has a very active research capability which has lead to many innovations in display technology. In addition there is a capability in display manufacturing of organic technologies as well as the licensed build of Japanese or Korean designs. Finally, Europe has a display systems capability in military products which is world class.

  19. Vacuum ultraviolet emission characteristics from He-Ne-Xe gas discharge in an alternating current plasma display panel cell

    NASA Astrophysics Data System (ADS)

    Seo, Jeong Hyun; Jeong, Heui Seob; Lee, Joo Yul; Yoon, Cha Keun; Kim, Joong Kyun; Whang, Ki-Woong

    2000-08-01

    We measured the time integrated vacuum ultraviolet (VUV) emission spectra of He-Ne-Xe gas mixture from a surface type alternating current (ac) plasma display panel cell. The measured emission lines are the resonance line (147 nm) from Xe*(1s4), the first continuum (150 nm) and the second continuum (173 nm) from Xe dimer excited states. The relative intensities of VUV spectral lines from Xe* and Xe2* are dependent on the He/Ne mixing ratio as well as the Xe partial and total pressure. The intensity of 147 nm VUV increases with the Ne content increase and Xe2* molecular emission increases with the He content increase. Infrared (IR) spectra and the time variation of VUV were measured to explain the reaction pathway and the effect of the mixing ratio of He/Ne on the spectral intensity. A detailed study for the decay time shows that the decay time of 147 nm has two time constants and the radiation of 150 and 173 nm results mainly from Xe*(1s5). The IR spectra shows that the contribution from Xe**(>6 s) to Xe*(1s5) and Xe*(1s4) in He-Xe is different from that of Ne-Xe. The change of IR intensity explains the spectral intensity variations of He-Xe and Ne-Xe discharge.

  20. Microspheres in Plasma Display Panels

    NASA Technical Reports Server (NTRS)

    2006-01-01

    Filling small bubbles of molten glass with gases is just as difficult as it sounds, but the technical staff at NASA is not known to shy away from a difficult task. When Microsphere Systems, Inc. (MSI), of Ypsilanti, Michigan, and Imaging Systems Technology, Inc. (IST), of Toledo, Ohio, were trying to push the limits of plasma displays but were having difficulty with the designs, NASA s Glenn Garrett Morgan Commercialization Initiative (GMCI) assembled key personnel at Glenn Research Center and Ohio State University for a brainstorming session to come up with a solution for the companies. They needed a system that could produce hollow, glass micro-sized spheres (microspheres) that could be filled with a variety of gasses. But the extremely high temperature required to force the micro-sized glass bubbles to form at the tip of a metal nozzle resulted in severe discoloration of the microspheres. After countless experiments on various glass-metal combinations, they had turned to the GMCI for help. NASA experts in advanced metals, ceramics, and glass concluded that a new design approach was necessary. The team determined that what was needed was a phosphate glass composition that would remain transparent, and they went to work on a solution. Six weeks later, using the design tips from the NASA team, Tim Henderson, president of MSI, had designed a new system in which all surfaces in contact with the molten glass would be ceramic instead of metal. Meanwhile, IST was able to complete a Phase I Small Business Innovation Research (SBIR) grant supported by the National Science Foundation (NSF) and supply a potential customer with samples of the microspheres for evaluation as filler materials for high-performance insulations.

  1. Improvement and efficient display of Bacillus thuringiensis toxins on M13 phages and ribosomes.

    PubMed

    Pacheco, Sabino; Cantón, Emiliano; Zuñiga-Navarrete, Fernando; Pecorari, Frédéric; Bravo, Alejandra; Soberón, Mario

    2015-12-01

    Bacillus thuringiensis (Bt) produces insecticidal proteins that have been used worldwide in the control of insect-pests in crops and vectors of human diseases. However, different insect species are poorly controlled by the available Bt toxins or have evolved resistance to these toxins. Evolution of Bt toxicity could provide novel toxins to control insect pests. To this aim, efficient display systems to select toxins with increased binding to insect membranes or midgut proteins involved in toxicity are likely to be helpful. Here we describe two display systems, phage display and ribosome display, that allow the efficient display of two non-structurally related Bt toxins, Cry1Ac and Cyt1Aa. Improved display of Cry1Ac and Cyt1Aa on M13 phages was achieved by changing the commonly used peptide leader sequence of the coat pIII-fusion protein, that relies on the Sec translocation pathway, for a peptide leader sequence that relies on the signal recognition particle pathway (SRP) and by using a modified M13 helper phage (Phaberge) that has an amber mutation in its pIII genomic sequence and preferentially assembles using the pIII-fusion protein. Also, both Cry1Ac and Cyt1Aa were efficiently displayed on ribosomes, which could allow the construction of large libraries of variants. Furthermore, Cry1Ac or Cyt1Aa displayed on M13 phages or ribosomes were specifically selected from a mixture of both toxins depending on which antigen was immobilized for binding selection. These improved systems may allow the selection of Cry toxin variants with improved insecticidal activities that could counter insect resistances.

  2. A Gastric Glycoform of MUC5AC Is a Biomarker of Mucinous Cysts of the Pancreas

    PubMed Central

    Sinha, Jessica; Cao, Zheng; Dai, Jianliang; Tang, Huiyuan; Partyka, Katie; Hostetter, Galen; Simeone, Diane M.; Feng, Ziding; Allen, Peter J.; Brand, Randall E.; Haab, Brian B.

    2016-01-01

    Molecular indicators to specify the risk posed by a pancreatic cyst would benefit patients. Previously we showed that most cancer-precursor cysts, termed mucinous cysts, produce abnormal glycoforms of the proteins MUC5AC and endorepellin. Here we sought to validate the glycoforms as a biomarker of mucinous cysts and to specify the oligosaccharide linkages that characterize MUC5AC. We hypothesized that mucinous cysts secrete MUC5AC displaying terminal N-acetylglucosamine (GlcNAc) in either alpha or beta linkage. We used antibody-lectin sandwich assays to detect glycoforms of MUC5AC and endorepellin in cyst fluid samples from three independent cohorts of 49, 32, and 66 patients, and we used monoclonal antibodies to test for terminal, alpha-linked GlcNAc and the enzyme that produces it. A biomarker panel comprising the previously-identified glycoforms of MUC5AC and endorepellin gave 96%, 96%, and 87% accuracy for identifying mucinous cysts in the three cohorts with an average sensitivity of 92% and an average specificity of 94%. Glycan analysis showed that MUC5AC produced by a subset of mucinous cysts displays terminal alpha-GlcNAc, a motif expressed in stomach glands. The alpha-linked glycoform of MUC5AC was unique to intraductal papillary mucinous neoplasms (IPMN), whereas terminal beta-linked GlcNAc was increased in both IPMNs and mucinous cystic neoplasms (MCN). The enzyme that synthesizes alpha-GlcNAc, A4GNT, was expressed in the epithelia of mucinous cysts that expressed alpha-GlcNAc, especially in regions with high-grade dysplasia. Thus IPMNs secrete a gastric glycoform of MUC5AC that displays terminal alpha-GlcNAc, and the combined alpha-GlcNAc and beta-GlcNAc glycoforms form an accurate biomarker of mucinous cysts. PMID:27992432

  3. Effects of Activated Carbon Surface Property on Structure and Activity of Ru/AC Catalysts

    NASA Astrophysics Data System (ADS)

    Xu, S. K.; Li, L. M.; Guo, N. N.

    2018-05-01

    The activated carbon (AC) was modified by supercritical (SC) methanol, HNO3 oxidation, or HNO3 oxidation plus SC methanol, respectively. Then, the original and the modified AC were used as supports for Ru/AC catalysts prepared via the impregnation method. The results showed that the SC methanol modification decreased the content of surface acidic groups of AC. While HNO3 oxidation displayed the opposite behavior. Furthermore, the dispersion of ruthenium and the activity of catalysts were highly dependent on the content of surface acidic groups, and the SC methanol modified sample exhibited the highest activity for hydrogenation of glucose.

  4. Development of Carbon-14 Waste Destruction and Recovery System Using AC Plasma Torch Technology Final Report CRADA No. TC02108.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Althouse, P.; McKannay, R. H.

    This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and ISOFLEX USA (ISOFLEX), to 1) develop and test a prototype waste destruction system ("System") using AC plasma torch technology to break down and drastically reduce the volume of Carbon-14 (C-14) contaminated medical laboratory wastes while satisfying all environmental regulations, and 2) develop and demonstrate methods for recovering 99%+ of the carbon including the C-14 allowing for possible re-use as a tagging and labeling tool in the biomedical industry.

  5. Effect of Microwave Non thermal Plasma Irradiation on the Adsorptive Properties of Active Carbon Preliminarily Impregnated with Poly(vinyl alcohol)

    NASA Astrophysics Data System (ADS)

    Ueshima, Masato; Toda, Eriko; Nakajima, Yuki; Sugiyama, Kazuo

    2010-08-01

    Microwave non thermal plasma irradiation was conducted on active carbon (AC) preliminarily impregnated with poly(vinyl alcohol) (PVA) in order to modify the adsorption properties of active carbon, particularly to increase hydrophobicity. The plasma was produced by applying microwave power on the PVA-impregnated active carbon (PVA/AC) placed in a low vacuum chamber (<10 Torr). The surface of the plasma-treated PVA/AC was imaged using scanning electron microscopy and atomic force microscopy (SEM and AFM, respectively), and analyzed using X-ray photoelectron spectroscopy (XPS). Hydrophobicity of the plasma-treated PVA/AC was compared to that of untreated PVA/AC and AC by a sinking test in water/methanol mixed solutions. The hydrophobicity drastically increased for PVA/AC treatment with 1-min plasma irradiation. The AFM results indicated that the surface roughness of the PVA/AC was dependent upon the hydrophobicity, rather than reduction of free energy due to reduction of polarized functional groups. NaOH and HCl adsorption onto the plasma-treated PVA/AC was also measured. Adsorption capacity of plasma-treated PVA/AC increased for NaOH, whereas it decreased for HCl. The plasma treatment not only increased the hydrophobicity of PVA/AC, but also changed its acid-base adsorption properties. We have developed a new material based on active carbon, which is light, hydrophobic and electrically conductive by using a combination of PVA sintering and plasma irradiation.

  6. Reliable Diagnosis of Carnitine Palmitoyltransferase Type IA Deficiency by Analysis of Plasma Acylcarnitine Profiles.

    PubMed

    Heiner-Fokkema, M Rebecca; Vaz, Frédéric M; Maatman, Ronald; Kluijtmans, Leo A J; van Spronsen, Francjan J; Reijngoud, Dirk-Jan

    2017-01-01

    Carnitine palmitoyltransferase IA (CPT-IA) deficiency is an inherited disorder of the carnitine cycle (MIM #255120). Patients affected by this deficiency might be missed easily because of lack of specific and sensitive biochemical markers. In this study, sensitivity and specificity of plasma free carnitine (C0) and long-chain acylcarnitines (lc-ac: C16:0-, C16:1-, C18:0-, C18:1- and C18:2-ac) was evaluated, including the sum of lc-ac (∑lc-ac) and the molar ratios C0/(C16:0-ac+C18:0-ac) and C0/∑lc-ac. Nine plasma acylcarnitine profiles of 4 CPT-IA deficient patients were compared with profiles of 2,190 subjects suspected of or diagnosed with an inherited disorder of metabolism. Age-dependent reference values were calculated based on the patient population without a definite diagnosis of an inborn error of metabolism (n = 1,600). Sensitivity, specificity, and Receiver Operating Characteristic (ROC) curves were calculated based on samples of the whole patient population. Concentrations of C0 in plasma were normal in all CPT-IA deficient patient samples. ROC analyses showed highest diagnostic values for C18:0-ac, C18:1-ac, and ∑lc-ac (AUC 1.000) and lowest for C0 (AUC 0.738). Combining two markers, i.e., a plasma C18:1-ac concentration <0.05 μmol/L and a molar ratio of C0/(C16:0-ac+C18:0-ac) >587, specificity to diagnose CPT-IA deficiency increased to 99.3% compared with either C18:1-ac (97.4%) or C0/(C16:0-ac+C18:0-ac) (96.9%) alone, all at a sensitivity of 100%. Combination of a low concentration of C18:1-ac with a high molar ratio of C0/(C16:0-ac+C18:0-ac) ratio in plasma has high diagnostic value for CPT-IA deficiency. Patients with a clinical suspicion of CPT-IA deficiency can be diagnosed with this test combination.

  7. Electron density dependence of impedance probe plasma potential measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, D. N.; Blackwell, D. D.; Amatucci, W. E.

    2015-08-15

    In earlier works, we used spheres of various sizes as impedance probes in demonstrating a method of determining plasma potential, φ{sub p}, when the probe radius is much larger than the Debye length, λ{sub D}. The basis of the method in those works [Walker et al., Phys. Plasmas 13, 032108 (2006); ibid. 15, 123506 (2008); ibid. 17, 113503 (2010)] relies on applying a small amplitude signal of fixed frequency to a probe in a plasma and, through network analyzer-based measurements, determining the complex reflection coefficient, Γ, for varying probe bias, V{sub b}. The frequency range of the applied signal ismore » restricted to avoid sheath resonant effects and ion contributions such that ω{sub pi} ≪ ω ≪ ω{sub pe}, where ω{sub pi} is the ion plasma frequency and ω{sub pe} is the electron plasma frequency. For a given frequency and applied bias, both Re(Z{sub ac}) and Im(Z{sub ac}) are available from Γ. When Re(Z{sub ac}) is plotted versus V{sub b}, a minimum predicted by theory occurs at φ{sub p} [Walker et al., Phys. Plasmas 17, 113503 (2010)]. In addition, Im(Z{sub ac}) appears at, or very near, a maximum at φ{sub p}. As n{sub e} decreases and the sheath expands, the minimum becomes harder to discern. The purpose of this work is to demonstrate that when using network analyzer-based measurements, Γ itself and Im(Z{sub ac}) and their derivatives are useful as accompanying indicators to Re(Z{sub ac}) in these difficult cases. We note the difficulties encountered by the most commonly used plasma diagnostic, the Langmuir probe. Spherical probe data is mainly used in this work, although we present limited data for a cylinder and a disk. To demonstrate the effect of lowered density as a function of probe geometry, we compare the cylinder and disk using only the indicator Re(Z{sub ac})« less

  8. Phage Display of a Biologically Active Bacillus thuringiensis Toxin

    PubMed Central

    Kasman, Laura M.; Lukowiak, Andrew A.; Garczynski, Stephen F.; McNall, Rebecca J.; Youngman, Phil; Adang, Michael J.

    1998-01-01

    Activated forms of Bacillus thuringiensis insecticidal toxins have consistently been found to form insoluble and inactive precipitates when they are expressed in Escherichia coli. Genetic engineering of these proteins to improve their effectiveness as biological pesticides would be greatly facilitated by the ability to express them in E. coli, since the molecular biology tools available for Bacillus are limited. To this end, we show that activated B. thuringiensis toxin (Cry1Ac) can be expressed in E. coli as a translational fusion with the minor phage coat protein of filamentous phage. Phage particles displaying this fusion protein were viable, infectious, and as lethal as pure toxin on a molar basis when the phage particles were fed to insects susceptible to native Cry1Ac. Enzyme-linked immunosorbent assay and Western blot analysis showed the fusion protein to be antigenically equivalent to native toxin, and micropanning with anti-Cry1Ac antibody was positive for the toxin-expressing phage. Phage display of B. thuringiensis toxins has many advantages over previous expression systems for these proteins and should make it possible to construct large libraries of toxin variants for screening or biopanning. PMID:9687463

  9. Pharmacokinetics of tilmicosin (Provitil powder and Pulmotil liquid AC) oral formulations in chickens.

    PubMed

    Abu-Basha, E A; Idkaidek, N M; Al-Shunnaq, A F

    2007-05-01

    A bioavailability and pharmacokinetics study of powder and liquid tilmicosin formulations was carried out in 18 healthy chickens according to a single-dose, two-period, two-sequence, crossover randomized design. The two formulations were Provitil and Pulmotil AC. Both drugs were administered to each chicken after an overnight fast on two treatment days separated by a 2-week washout period. A modified rapid and sensitive HPLC method was used for determination of tilmicosin concentrations in chicken plasma. Various pharmacokinetic parameters including area under plasma concentration-time curve (AUC(0-72)), maximum plasma concentration (C(max)), time to peak concentration (t(max)), elimination half-life (t(1/2beta)), elimination rate (k(el)), clearance (Cl(B)), mean residence time (MRT) and volume of distribution (V(d,area)) were determined for both formulations. The average means of AUC(0-72) for Provitil and Pulmotil AC were very close (24.24 +/- 3.86, 21.82 +/- 3.14 (microg x h)/ml, respectively), with no significant differences based on ANOVA. The relative bioavailability of Provitil as compared to Pulmotil AC was 111%. In addition, there were no significant differences in the C(max) (2.09 +/- 0.37, 2.12 +/- 0.40 microg/ml), tmax (3.99 +/- 0.84, 5.82 +/- 1.04 h), t(1/2beta) (47.4 +/- 9.32, 45.0 +/- 5.73 h), k(el) (0.021 +/- 0.0037, 0.022 +/- 0.0038 h(-1)), Cl(B) (19.73 +/- 3.73, 21.37 +/- 4.54ml/(min/kg)), MRT (71.20 +/- 12.87, 67.15 +/- 9.01 h) and V(d,area) (1024.8 +/- 87.5, 1009.8 +/- 79.5 ml/kg) between Pulmotil AC and Provitil, respectively. In conclusion, tilmicosin was rapidly absorbed and slowly eliminated after oral administration of single dose of tilmicosin aqueous and powder formulations. Provitil and Pulmotil AC can be used as interchangeable therapeutic agents.

  10. Plasma firocoxib concentrations after intra-articular injection of autologous conditioned serum prepared from firocoxib positive horses.

    PubMed

    Ortved, K F; Goodale, M B; Ober, C; Maylin, G A; Fortier, L A

    2017-12-01

    Orthobiologics such as autologous conditioned serum (ACS) are often used to treat joint disease in horses. Because ACS is generated from the horse's own blood, any medication administered at the time of preparation would likely be present in stored ACS, which could lead to an inadvertent positive drug test following intra-articular (IA) injection. The main objective of this study was to determine if ACS prepared from firocoxib positive horses could result in detectable plasma concentrations of the drug following IA injection. Firocoxib was administered to six horses at 0.1mg/kg PO twice at a 24h interval. Blood was obtained at 4h following the second dose and transferred to a separate syringe (Arthrex IRAP II) for ACS preparation. Plasma and ACS concentrations of firocoxib were analysed by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). When horses were confirmed firocoxib negative, 7.5mL of ACS was injected into both tarsocrural joints. Blood samples were collected at 0, 4, 8, 12, 24, and 48h, and firocoxib concentration was measured. Mean (±standard error of the mean, SEM) plasma concentration of firocoxib 4h following the second dose was 33.3±4.72ng/mL. Mean (±SEM) firocoxib concentration in ACS was 35.4±4.47ng/mL. Fourteen days following the second and last dose of firocoxib, mean plasma concentration was below the lower limit of detection (LOD=1ng/mL) in all horses. Following IA injection of ACS, plasma concentrations of firocoxib remained below LOD at all times in all horses. ACS generated from horses with therapeutic plasma concentrations of firocoxib did not contain sufficient firocoxib to lead to a positive plasma drug test following IA administration. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Pulsed-DC DBD Plasma Actuators

    NASA Astrophysics Data System (ADS)

    Duong, Alan; Corke, Thomas; Thomas, Flint

    2017-11-01

    A power system for dielectric barrier discharge (DBD) plasma actuators that utilizes a pulsed-DC waveform is presented. The plasma actuator arrangement is identical to most typical AC-DBD designs with staggered electrodes that are separated by a dielectric insulator. A key difference is that the pulsed-DC actuator utilizes a DC voltage source to drive the actuator instead of an AC voltage input. The DC source is supplied to both electrodes. The exposed electrode remains constant in time while the encapsulated electrode is periodically grounded for short instances then is allowed to rise to the source DC level. Further investigation of the pulsed-DC plasma actuator was conducted. Time-resolved velocity measurements were done to characterize the induced velocity field generated by the pulsed-DC plasma actuator. A model of the pulsed-DC plasma actuator is developed in LTspice for further study. The work presented are intended in developing a model to be used in CFD flow control simulations. NASA SBIR NNX14CC12C.

  12. Here Be Dragons: Characterization of ACS/WFC Scattered Light Anomalies

    NASA Astrophysics Data System (ADS)

    Porterfield, B.; Coe, D.; Gonzaga, S.; Anderson, J.; Grogin, N.

    2016-11-01

    We present a study characterizing scattered light anomalies that occur near the edges of Advanced Camera for Surveys (ACS) Wide Field Channel (WFC) images. We inspected all 8,573 full-frame ACS/WFC raw images with exposure times longer than 350 seconds obtained in the F606W and F814W filters from 2002 to October 2013. We visually identified two particular scattered light artifacts known as "dragon's breath" and edge glow. Using the 2MASS point source catalog and Hubble Guide Star Catalog (GSC II), we identified the stars that caused these artifacts. The stars are all located in narrow bands ( 3" across) just outside the ACS/WFC field of view (2" - 16" away). We provide a map of these risky areas around the ACS/WFC detectors - users should avoid positioning bright stars in these regions when designing ACS/WFC imaging observations. We also provide interactive webpages which display all the image artifacts we identified, allowing users to see examples of the severity of artifacts they might expect for a given stellar magnitude at a given position relative to the ACS/WFC field of view. On average, 10th (18th) magnitude stars produce artifacts about 1,000 (100) pixels long. But the severity of these artifacts can vary strongly with small positional shifts (∼ 1"). The results are similar for both filters (F606W and F814W) when expressed in total fluence, or flux multiplied by exposure time.

  13. Effects in vivo of iohexol and diatrizoate on human plasma acetyl- and butyryl-cholinesterase activity.

    PubMed

    Mironidou, M; Katsimba, D; Kokkas, B; Kaitartzis, C; Karamanos, G; Christopoulos, S

    2001-03-01

    The aim of this study was to evaluate the effects of two iodinate contrast agents (CA), iohexol and diatrizoate, on human plasma acetyl-(AC) and butyrylcholinesterase(BC) activity. Forty-eight patients (24 males and 24 females) scheduled for intravenous pyelography were randomly divided into four groups of 6 males and 6 females each, receiving as CA, respectively: iohexol (Omnipaque, Schering) 0.6 ml/kg body weight (G1); iohexol 1.2 mg/kg (G2); sodium and meglumine diatrizoate 58% (Urografin, Schering) 0.6 ml/kg (G3); sodium and meglumine diatrizoate 58% 1.2 ml/kg (G4). Blood samples were taken before and 5, 10, and 20 min after the injection. Enzymatic activity of AC and BC were measured by spectrophotometry. Plasma concentration of K, Na, Ca, and Mg was measured in all blood samples; blood pressure and plasma pH were measured after each sample collection. Statistical analysis was performed by Student's test. In G1 a reversible decrease of AC (12.9%) and BC (8.2%) plasma activity was observed at 10 min. In G2 a progressive decrease of AC (13.9%) and BC (18.4%) plasma activity was observed with a maximum at 20 min. In G3 a modest reversible decrease of BC plasma activity (5.4%) was observed. In G4 a modest progressive decrease of AC (7.3%) and BC (6.5%) plasma activities was observed. In all cases, AC and BC plasma activities remained within the normal range of values. Plasma concentration of K, Na, Ca, and Mg, as well as pH and systolic and diastolic pressure, did not show any change. No adverse effects was observed in our patients. Iohexol and diatrizoate induce in vivo a significant decrease of AC and BC plasma activities. The decrease is more pronounced for iohexol, a non ionic CA, which has a lower pharmacotoxicity than diatrizoate and adverse effects rate. No inference can be drawn about the relationship between plasma cholinesterase activity and adverse effects.

  14. A preliminary study of flat-panel displays

    NASA Technical Reports Server (NTRS)

    Yancey, K. E.

    1986-01-01

    Six display technologies that might be of future value in a spacelab workstation are discussed. Some have been developed to the point where they could be used as a computer display while others have not. The display technologies studied are electroluminescents, light-emitting didodes, gas plasma, liquid crystal, electrochromic, and electrophoretic. An explanation of each mechanism is provided along with the state-of-the-art development.

  15. AC Initiation System.

    DTIC Science & Technology

    An ac initiation system is described which uses three ac transmission signals interlocked for safety by frequency, phase, and power discrimination...The ac initiation system is pre-armed by the application of two ac signals have the proper phases, and activates a load when an ac power signal of the proper frequency and power level is applied. (Author)

  16. Plasma Treated Active Carbon for Capacitive Deionization of Saline Water

    DOE PAGES

    Zeng, Aiping; Shrestha, Maheshwar; Wang, Keliang; ...

    2017-01-01

    The plasma treatment on commercial active carbon (AC) was carried out in a capacitively coupled plasma system using Ar + 10% O 2at pressure of 4.0 Torr. The RF plasma power ranged from 50 W to 100 W and the processing time was 10 min. The carbon film electrode was fabricated by electrophoretic deposition. Micro-Raman spectroscopy revealed the highly increased disorder of sp 2C lattice for the AC treated at 75 W. An electrosorption capacity of 6.15 mg/g was recorded for the carbon treated at 75 W in a 0.1 mM NaCl solution when 1.5 V was applied for 5more » hours, while the capacity of the untreated AC was 1.0 mg/g. The plasma treatment led to 5.09 times increase in the absorption capacity. The jump of electrosorption capacity by plasma treatment was consistent with the Raman spectra and electrochemical double layer capacitance. This work demonstrated that plasma treatment was a potentially efficient approach to activating biochar to serve as electrode material for capacitive deionization (CDI).« less

  17. The scope of phage display for membrane proteins.

    PubMed

    Vithayathil, Rosemarie; Hooy, Richard M; Cocco, Melanie J; Weiss, Gregory A

    2011-12-09

    Numerous examples of phage display applied to soluble proteins demonstrate the power of the technique for protein engineering, affinity reagent discovery and structure-function studies. Recent reports have expanded phage display to include membrane proteins (MPs). The scope and limitations of MP display remain undefined. Therefore, we report data from the phage display of representative types of membrane-associated proteins including plasma, nuclear, peripheral, single and multipass. The peripheral MP neuromodulin displays robustly with packaging by conventional M13-KO7 helper phage. The monotopic MP Nogo-66 can also display on the phage surface, if packaged by the modified M13-KO7(+) helper phage. The modified phage coat of KO7(+) can better mimic the zwitterionic character of the plasma membrane. Four examples of putatively α-helical, integral MPs failed to express as fusions to an anchoring phage coat protein and therefore did not display on the phage surface. However, the β-barrel MPs ShuA (Shigella heme uptake A) and MOMP (major outer membrane protein), which pass through the membrane 22 and 16 times, respectively, can display surprisingly well on the surfaces of both conventional and KO7(+) phages. The results provide a guide for protein engineering and large-scale mutagenesis enabled by the phage display of MPs. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Simulation of the AC corona phenomenon with experimental validation

    NASA Astrophysics Data System (ADS)

    Villa, Andrea; Barbieri, Luca; Marco, Gondola; Malgesini, Roberto; Leon-Garzon, Andres R.

    2017-11-01

    The corona effect, and in particular the Trichel phenomenon, is an important aspect of plasma physics with many technical applications, such as pollution reduction, surface and medical treatments. This phenomenon is also associated with components used in the power industry where it is, in many cases, the source of electro-magnetic disturbance, noise and production of undesired chemically active species. Despite the power industry to date using mainly alternating current (AC) transmission, most of the studies related to the corona effect have been carried out with direct current (DC) sources. Therefore, there is technical interest in validating numerical codes capable of simulating the AC phenomenon. In this work we describe a set of partial differential equations that are comprehensive enough to reproduce the distinctive features of the corona in an AC regime. The model embeds some selectable chemical databases, comprising tens of chemical species and hundreds of reactions, the thermal dynamics of neutral species and photoionization. A large set of parameters—deduced from experiments and numerical estimations—are compared, to assess the effectiveness of the proposed approach.

  19. JTEC panel on display technologies in Japan

    NASA Technical Reports Server (NTRS)

    Tannas, Lawrence E., Jr.; Glenn, William E.; Credelle, Thomas; Doane, J. William; Firester, Arthur H.; Thompson, Malcolm

    1992-01-01

    This report is one in a series of reports that describes research and development efforts in Japan in the area of display technologies. The following are included in this report: flat panel displays (technical findings, liquid crystal display development and production, large flat panel displays (FPD's), electroluminescent displays and plasma panels, infrastructure in Japan's FPD industry, market and projected sales, and new a-Si active matrix liquid crystal display (AMLCD) factory); materials for flat panel displays (liquid crystal materials, and light-emissive display materials); manufacturing and infrastructure of active matrix liquid crystal displays (manufacturing logistics and equipment); passive matrix liquid crystal displays (LCD basics, twisted nematics LCD's, supertwisted nematic LCD's, ferroelectric LCD's, and a comparison of passive matrix LCD technology); active matrix technology (basic active matrix technology, investment environment, amorphous silicon, polysilicon, and commercial products and prototypes); and projection displays (comparison of Japanese and U.S. display research, and technical evaluation of work).

  20. Plasma injector for a three-phase plasma torch with rail electrodes and some results of its investigation

    NASA Astrophysics Data System (ADS)

    Dudnik, Yu D.; Borovskoy, A. M.; Shiryaev, V. N.; Safronov, A. A.; Kuznetsov, V. E.; Vasilieva, O. B.; Pavlov, A. V.; Ivanov, D. V.

    2018-01-01

    Plasma injector made on the basis of the alternating-current plasma torch designed for the three-phase ac plasma torch with 100-500 kWrail electrodes is studied. The construction of the plasma injector is examined. Different materials for manufacture of injector electrodes are investigated. Current-voltage characteristics of the injector are obtained. Investigations of the plasma jet are carried out, and the jet temperature dependence versus the gas flow rate and electric power of the injector is measured.

  1. The isolated MUC5AC gene product from human ocular mucin displays intramolecular conformational heterogeneity.

    PubMed

    Round, Andrew N; McMaster, Terence J; Miles, Mervyn J; Corfield, Anthony P; Berry, Monica

    2007-06-01

    Atomic force microscopy (AFM) has been used to show that human ocular mucins contain at least three distinct polymer conformations, separable by isopycnic density gradient centrifugation. In this work we have used affinity purification against the anti(mucin peptide core) monoclonal antibody 45M1 to isolate MUC5AC gene products, a major component of human ocular mucins. AFM images confirm that the affinity-purified polymers adopt distinct conformations that coidentify with two of those observed in the parent population, and further reveal that these two different conformations can be present within the same polymer. AFM images of the complexes formed after incubation of 45M1 with the parent sample reveal different rates of binding to the two MUC5AC polymer types. The variability of gene products within a mucin population was revealed by analyzing the height distributions along the polymer contour and periodicities in distances between occupied antibody binding sites. AFM analysis of mucin polymers at the single molecule level provides new information about the genetic origins of individual polymers and the contributions of glycosylation to the physicochemical properties of mucins, which can be correlated with information obtained from biochemistry, antibody binding assays, and molecular biology techniques.

  2. Plasma apolipoprotein O level increased in the patients with acute coronary syndrome

    PubMed Central

    Yu, Bi-lian; Wu, Chen-lu; Zhao, Shui-ping

    2012-01-01

    Apolipoprotein (apo) O is a novel apolipoprotein that is present predominantly in high density lipoprotein (HDL). However, overexpression of apoO does not impact on plasma HDL levels or functionality in human apoA-I transgenic mice. Thus, the physiological function of apoO is not yet known. In the present study, we investigated relationships between plasma apoO levels and high-sensitive C-reactive protein (hs-CRP) levels, as well as other lipid parameters in healthy subjects (n = 111) and patients with established acute coronary syndrome (ACS) (n = 50). ApoO was measured by the sandwich dot-blot technique with recombinant apoO as a protein standard. Mean apoO level in healthy subjects was 2.21 ± 0.83 µg/ml whereas it was 4.94 ± 1.59 µg/ml in ACS patients. There were significant differences in plasma level of apoO between two groups (P < 0.001). In univariate analysis, apoO correlated significantly with lg(hsCRP) (r = 0.48, P < 0.001) in ACS patients. Notably, no significant correlation between apoO and other lipid parameters was observed. Logistic regression analysis showed that plasma apoO level was an independent predictor of ACS (OR = 5.61, 95% CI 2.16–14.60, P < 0.001). In conclusion, apoO increased in ACS patients, and may be regarded as an independent inflammatory predictor of ACS patients. PMID:22693255

  3. Translation, modification and cellular distribution of two AC4 variants of African cassava mosaic virus in yeast and their pathogenic potential in plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hipp, Katharina, E-mail: katharina.hipp@bio.uni-st

    Plant infecting geminiviruses encode a small (A)C4 protein within the open reading frame of the replication-initiator protein. In African cassava mosaic virus, two in-frame start codons may be used for the translation of a longer and a shorter AC4 variant. Both were fused to green fluorescent protein or glutathione-S-transferase genes and expressed in fission yeast. The longer variant accumulated in discrete spots in the cytoplasm, whereas the shorter variant localized to the plasma membrane. A similar expression pattern was found in plants. A myristoylation motif may promote a targeting of the shorter variant to the plasma membrane. Mass spectrometry analysismore » of the yeast-expressed shorter variant detected the corresponding myristoylation. The biological relevance of the second start codon was confirmed using mutated infectious clones. Whereas mutating the first start codon had no effect on the infectivity in Nicotiana benthamiana plants, the second start codon proved to be essential. -- Highlights: •The ACMV AC4 may be translated from one or the other in-frame start codon. •Both AC4 variants are translated in fission yeast. •The long AC4 protein localizes to the cytoplasm, the short to the plasma membrane. •The short variant is myristoylated in yeast and may promote membrane localization. •Only the shorter AC4 variant has an impact on viral infections in plants.« less

  4. Large Volume Non-Equilibrium Air Plasma at Atmospheric Pressure: A Novel Method with Low Power Requirements

    DTIC Science & Technology

    2007-02-28

    of magnitude in size. Also unlike corona -like devices such as the plasma needle , which generates 2-3 mm long plasma at the tip of a sharp wire...Distribution Unlimited Table of Contents Abstract AC System with Water Electrode Current voltage characteristics Plasma diagnostics results Experimental setup...Laroussi, PI. 4 AC SYSTEM WITH WATER ELECTRODE Recently, non-equilibrium atmospheric pressure plasmas have been used in a variety of material processing

  5. Charge dependence of the plasma travel length in atmospheric-pressure plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yambe, Kiyoyuki; Konda, Kohmei; Masuda, Seiya

    Plasma plume is generated using a quartz tube, helium gas, and foil electrode by applying AC high voltage under the atmosphere. The plasma plume is released into the atmosphere from inside of the quartz tube and is seen as the continuous movement of the plasma bullet. The travel length of plasma bullet is defined from plasma energy and force due to electric field. The drift velocity of plasma bullet has the upper limit under atmospheric-pressure because the drift velocity is determined from the balance between electric field and resistive force due to collisions between plasma and air. The plasma plumemore » charge depends on the drift velocity. Consequently, in the laminar flow of helium gas flow state, the travel length of the plasma plume logarithmically depends on the plasma plume charge which changes with both the electric field and the resistive force.« less

  6. Therapeutic plasma exchange: a paired comparison of Fresenius AS104 vs. COBE Spectra.

    PubMed

    Burgstaler, E A; Pineda, A A

    2001-01-01

    For therapeutic plasma exchange (TPE), continuous flow separators are known to be efficient as exemplified by Fresenius AS104 and COBE Spectra. The AS104 uses an interface monitoring system in the centrifuge during TPE, whereas Spectra uses computer algorithms to establish the plasma-cell interface. To determine the plasma collection efficiency (PLCE), anticoagulant (AC) volumes used, and platelets (PLT) lost of the AS104 and the Spectra, we performed a prospective paired comparison of 20 TPE (each machine). The study included 17 patients, 1.3 plasma volume exchanges (without AC), equal inlet rates, and AC ratio of 13:1. Processing times did not include reinfuse mode. Platelet loss was determined by sampling the collection bags. Inlet rates were between 60-110 ml/min. Diagnosis included peripheral neuropathies, TTP and cryoglobulinemia. The AS104 had significantly (P<0.0001) lower average whole blood processed (F:6,601 vs. S:8,584 ml), AC volume (F:532 vs. S:719 ml), and processing time (F:80 vs. S:102 minutes) than Spectra. The AS104 had significantly (P<0.0001) higher average plasma flow rates (F:53 vs. S:44 ml/minute), plasma collection efficiency (F:90 vs. S:69%), and platelet loss (F:2.0 vs. S:0.14 x 10(11) plt) than Spectra. Platelet loss correlated with inlet flow rate with the AS104 but not with the Spectra. The AS104 has a significantly higher collection efficiency than Spectra allowing it to remove the same amount of plasma in significantly less time, by processing significantly less blood, using significantly less AC, but removing significantly more platelets than Spectra. Copyright 2001 Wiley-Liss, Inc.

  7. Carbon Nanotubes/Nanofibers by Plasma Enhanced Chemical Vapour Deposition

    NASA Technical Reports Server (NTRS)

    Teo, K. B. K.; Hash, D. B.; Bell, M. S.; Chhowalla, M.; Cruden, B. A.; Amaratunga, G. A. J.; Meyyappan, M.; Milne, W. I.

    2005-01-01

    Plasma enhanced chemical vapour deposition (PECVD) has been recently used for the production of vertically aligned carbon nanotubedfibers (CN) directly on substrates. These structures are potentially important technologically as electron field emitters (e.g. microguns, microwave amplifiers, displays), nanoelectrodes for sensors, filter media, superhydrophobic surfaces and thermal interface materials for microelectronics. A parametric study on the growth of CN grown by glow discharge dc-PECVD is presented. In this technique, a substrate containing thin film Ni catalyst is exposed to C2H2 and NH3 gases at 700 C. Without plasma, this process is essentially thermal CVD which produces curly spaghetti-like CN as seen in Fig. 1 (a). With the plasma generated by biasing the substrate at -6OOV, we observed that the CN align vertically during growth as shown in Fig. l(b), and that the magnitude of the applied substrate bias affects the degree of alignment. The thickness of the thin film Ni catalyst was found to determine the average diameter and inversely the length of the CN. The yield and density of the CN were controlled by the use of different diffusion barrier materials under the Ni catalyst. Patterned CN growth [Fig. l(c)], with la variation in CN diameter of 4.1% and 6.3% respectively, is achieved by lithographically defining the Ni thin film prior to growth. The shape of the structures could be varied from very straight nanotube-like to conical tip-like nanofibers by increasing the ratio of C2H2 in the gas flow. Due to the plasma decomposition of C2H2, amorphous carbon (a-C) is an undesirable byproduct which could coat the substrate during CN growth. Using a combination of depth profiled Auger electron spectroscopy to study the substrate and in-situ mass spectroscopy to examine gas phase neutrals and ions, the optimal conditions for a-C free growth of CN is determined.

  8. Scaling laws for AC gas breakdown and implications for universality

    NASA Astrophysics Data System (ADS)

    Loveless, Amanda M.; Garner, Allen L.

    2017-10-01

    The reduced dependence on secondary electron emission and electrode surface properties makes radiofrequency (RF) and microwave (MW) plasmas advantageous over direct current (DC) plasmas for various applications, such as microthrusters. Theoretical models relating molecular constants to alternating current (AC) breakdown often fail due to incomplete understanding of both the constants and the mechanisms involved. This work derives simple analytic expressions for RF and MW breakdown, demonstrating the transition between these regimes at their high and low frequency limits, respectively. We further show that the limiting expressions for DC, RF, and MW breakdown voltage all have the same universal scaling dependence on pressure and gap distance at high pressure, agreeing with experiment.

  9. Positive association between KCNJ5 rs2604204 (A/C) polymorphism and plasma aldosterone levels, but also plasma renin and angiotensin I and II levels, in newly diagnosed hypertensive Chinese: a case-control study.

    PubMed

    Wang, H; Weng, C; Chen, H

    2017-07-01

    Variants in G protein-coupled inward rectifier K + channels 4 (GIRK4 also known as KCNJ5) gene are associated with primary aldosteronism, which is the most common cause of secondary hypertension. The KCNJ5 rs2604204 variant was shown to be common (minor allele frequency=32.5%) in Chinese patients with essential hypertension (EH). The relationship between KCNJ5 variant and plasma aldosterone (ALD) levels in EH patients has not been reported. We collected 229 patients with newly diagnosed EH without any antihypertensive agents. According to the median standing plasma ALD, high-ALD and control groups were divided. Clinical data and blood samples were collected. KCNJ5 rs2604204 genotype was determined by PCR. The results showed that the levels of triglyceride, uric acid, insulin, insulin resistance (IR) index, renin, angiotensin I (Ang I), angiotensin II (Ang II), cortisol, 24 h mean systolic blood pressure (SBP) and daytime mean SBP were significantly increased in the high-ALD group than those in the control group, as well as 24 h s.d. of SBP and diastolic BP (DBP), and 24 h coefficient of variance of SBP and DBP. Notably, the distribution frequency of AC and CC genotypes, and the C allele of KCNJ5 were also significantly higher in the high-ALD group. Logistic regression analysis showed that the C allele of KCNJ5 rs2604204 was one risk factor for increased plasma ALD in Chinese EH patients (P=0.008, odds ratio=2.2 (95% confidence interval 1.2-4.1)). Our findings indicated that the variation of plasma ALD might be associated with increased IR and BP variability. Moreover, KCNJ5 rs2604204 polymorphism was related to increased plasma ALD level, but also plasma renin, Ang I and II levels in newly diagnosed, never-treated EH patients.

  10. AC-130 Employment

    DTIC Science & Technology

    2006-01-01

    1 AC -130 Employment Subject Area Aviation EWS 2006 Author Captain Robert Hornick, USMC Report Documentation Page Form ApprovedOMB No. 0704...00-2006 4. TITLE AND SUBTITLE AC -130 Employment 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER... AC -130 gunship is an aircraft that can provide all of these needs. Regrettably, there are too few AC -130’s in the inventory to cover all the needs

  11. Substituted Phthalimide AC94377 Is a Selective Agonist of the Gibberellin Receptor GID11[OPEN

    PubMed Central

    Otani, Masato; Shimotakahara, Hiroaki; Yoon, Jung-Min; Park, Seung-Hyun; Miyaji, Tomoko; Nakano, Takeshi; Nakamura, Hidemitsu; Nakajima, Masatoshi

    2017-01-01

    Gibberellin (GA) is a major plant hormone that regulates plant growth and development and is widely used as a plant growth regulator in agricultural production. There is an increasing demand for function-limited GA mimics due to the limitations on the agronomical application of GA to crops, including GA’s high cost of producing and its leading to the crops’ lodging. AC94377, a substituted phthalimide, is a chemical that mimics the growth-regulating activity of GAs in various plants, despite its structural difference. Although AC94377 is widely studied in many weeds and crops, its mode of action as a GA mimic is largely unknown. In this study, we confirmed that AC94377 displays GA-like activities in Arabidopsis (Arabidopsis thaliana) and demonstrated that AC94377 binds to the Arabidopsis GIBBERELLIN INSENSITIVE DWARF1 (GID1) receptor (AtGID1), forms the AtGID1-AC94377-DELLA complex, and induces the degradation of DELLA protein. Our results also indicated that AC94377 is selective for a specific subtype among three AtGID1s and that the selectivity of AC94377 is attributable to a single residue at the entrance to the hydrophobic pocket of GID1. We conclude that AC94377 is a GID1 agonist with selectivity for a specific subtype of GID1, which could be further developed and used as a function-limited regulator of plant growth in both basic study and agriculture. PMID:27899534

  12. Activity of a new hydrogen sulfide-releasing aspirin (ACS14) on pathological cardiovascular alterations induced by glutathione depletion in rats.

    PubMed

    Rossoni, Giuseppe; Manfredi, Barbara; Tazzari, Valerio; Sparatore, Anna; Trivulzio, Silvio; Del Soldato, Piero; Berti, Ferruccio

    2010-12-01

    We investigated the effects of the hydrogen sulfide (H₂S)-releasing derivatives of aspirin (ACS14) and salicylic acid (ACS21) in a rat model of metabolic syndrome induced by glutathione (GSH) depletion, causing hypertension and other pathological cardiovascular alterations. GSH depletion was induced in normal rats by the GSH-synthase inhibitor buthionine sulfoximine (BSO, 30 mmol/L day for seven days in the drinking water). Systolic blood pressure and heart rate were measured daily by the tail-cuff method, and plasma thromboxane B₂, 6-keto-prostaglandin F(2α), 8-isoprostane, GSH, insulin and glucose were determined at the end of the seven-day BSO schedule. In addition, ischemia/reperfusion-induced myocardial dysfunction and endothelial dysfunction were assayed on isolated heart and aortic rings, respectively. Unlike aspirin and salicylic acid, ACS14 and ACS21 reduced BSO-induced hypertension, also lowering plasma levels of thromboxane B₂, 8-isoprostane and insulin, while GSH remained in the control range. Neither ACS14 nor ACS21 caused gastric lesions. Both restored the endothelial dysfunction observed in aortic rings from BSO-treated rats, and in ischemia/reperfusion experiments they lowered left ventricular end-diastolic pressure, consequently improving the developed pressure and the maximum rise and fall of left ventricular pressure. Together with this improvement of heart mechanics there were reductions in the activity of creatine kinase and lactate dehydrogenase in the cardiac perfusate. This implies that H₂S released by both ACS14 and ACS21 was involved in protecting the heart from ischemia/reperfusion, and significantly limited vascular endothelial dysfunction in aortic tissue and the related hypertension. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. Advances in display technology III; Proceedings of the Meeting, Los Angeles, CA, January 18, 19, 1983

    NASA Astrophysics Data System (ADS)

    Schlam, E.

    1983-01-01

    Human factors in visible displays are discussed, taking into account an introduction to color vision, a laser optometric assessment of visual display viewability, the quantification of color contrast, human performance evaluations of digital image quality, visual problems of office video display terminals, and contemporary problems in airborne displays. Other topics considered are related to electroluminescent technology, liquid crystal and related technologies, plasma technology, and display terminal and systems. Attention is given to the application of electroluminescent technology to personal computers, electroluminescent driving techniques, thin film electroluminescent devices with memory, the fabrication of very large electroluminescent displays, the operating properties of thermally addressed dye switching liquid crystal display, light field dichroic liquid crystal displays for very large area displays, and hardening military plasma displays for a nuclear environment.

  14. Computer soundcard as an AC signal generator and oscilloscope for the physics laboratory

    NASA Astrophysics Data System (ADS)

    Sinlapanuntakul, Jinda; Kijamnajsuk, Puchong; Jetjamnong, Chanthawut; Chotikaprakhan, Sutharat

    2018-01-01

    The purpose of this paper is to develop both an AC signal generator and a dual-channel oscilloscope based on standard personal computer equipped with sound card as parts of the laboratory of the fundamental physics and the introduction to electronics classes. The setup turns the computer into the two channel measured device which can provides sample rate, simultaneous sampling, frequency range, filters and others essential capabilities required to perform amplitude, phase and frequency measurements of AC signal. The AC signal also generate from the same computer sound card output simultaneously in any waveform such as sine, square, triangle, saw-toothed pulsed, swept sine and white noise etc. These can convert an inexpensive PC sound card into powerful device, which allows the students to measure physical phenomena with their own PCs either at home or at university attendance. A graphic user interface software was developed for control and analysis, including facilities for data recording, signal processing and real time measurement display. The result is expanded utility of self-learning for the students in the field of electronics both AC and DC circuits, including the sound and vibration experiments.

  15. MicroPPT-Based Secondary/Backup ACS for a 160-m, 450-kg Solar Sail Spacecraft

    NASA Technical Reports Server (NTRS)

    Wie, Bong; Murphy, David

    2005-01-01

    Solar sail tip-mounted, lightweight pulsed plasma thrusters (PPTs) are proposed for a secondary (or backup) attitude control system (ACS) of a 160-m, 450-kg solar sail spacecraft of the Solar Polar Imager (SPI) mission. A propellantless primary ACS of the SPI sailcraft employs trim control masses running along mast lanyards for pitch/yaw control together with roll stabilizer bars at the mast tips for quadrant tilt (roll) control. The robustness of such a propellantless primary ACS would be further enhanced by a secondary ACS utilizing tip-mounted, lightweight PPTs. The microPPT-based ACS is intended mainly for attitude recovery maneuvers from various off-nominal conditions that cannot be reliably handled by the propellantless primary ACS. However, it can also be employed for: i) the checkout or standby mode prior to and during sail deployment, ii) the post-deployment transition mode (prior to the propellantless primary ACS mode operation), iii) the solar sailing cruise mode of a trimmed sailcraft, and iv) the spin-stabilized, sun-pointing, safe mode. Although a conventional bus ACS is required for the SPI mission as the sail is jettisoned at the start of its science mission phase, the microPPT-based ACS option promises greater redundancy and robustness for the SPI mission. For other sailing missions, where the sail is never jettisoned, this secondary ACS provides a lower-cost, lower-mass propulsion for deployment control and greater redundancy than any traditional reaction-jet control system. This paper presents an overview nf the state--of-the--art microPPT technology, the design requirements of microPPTs for solar sail attitude control, and the preliminary ACS design and simulation results.

  16. Modeling Laser-Plasma Interactions in a Magnetized Plasma

    NASA Astrophysics Data System (ADS)

    Los, Eva; Strozzi, D. J.; Chapman, T.; Farmer, W. A.; Cohen, B. I.

    2017-10-01

    We consider how laser-plasma interactions, namely stimulated Raman and Brillouin scattering, develop in the presence of a background magnetic field. Externally-launched waves in magnetized plasma have been studied in magnetic fusion devices for several decades, with relatively little work on their parametric decay. The topic has received scant attention in the laser-plasma and high-energy-density fields, but is becoming timely. The MagLIF pulsed-power scheme relies on an imposed axial field and laser-preheat [S. Slutz et al., Phys. Rev. Lett. 2012]. Imposing a field on a hohlraum to reduce hotspot losses has also been proposed [L. J. Perkins et al., Phys. Plasmas 2013]. We consider how the field affects the linear light waves in a plasma, e.g. by decoupling the left- and right- circular polarizations (Faraday rotation). Parametric instability growth rates are presented, as functions of plasma conditions, field strength, and geometry. The scattered-light spectrum, which is routinely measured, is also found. Work performed under auspices of US DoE by LLNL under Contract DE-AC52-07NA27344.

  17. Display of a maize cDNA library on baculovirus infected insect cells.

    PubMed

    Meller Harel, Helene Y; Fontaine, Veronique; Chen, Hongying; Jones, Ian M; Millner, Paul A

    2008-08-12

    Maize is a good model system for cereal crop genetics and development because of its rich genetic heritage and well-characterized morphology. The sequencing of its genome is well advanced, and new technologies for efficient proteomic analysis are needed. Baculovirus expression systems have been used for the last twenty years to express in insect cells a wide variety of eukaryotic proteins that require complex folding or extensive posttranslational modification. More recently, baculovirus display technologies based on the expression of foreign sequences on the surface of Autographa californica (AcMNPV) have been developed. We investigated the potential of a display methodology for a cDNA library of maize young seedlings. We constructed a full-length cDNA library of young maize etiolated seedlings in the transfer vector pAcTMVSVG. The library contained a total of 2.5 x 10(5) independent clones. Expression of two known maize proteins, calreticulin and auxin binding protein (ABP1), was shown by western blot analysis of protein extracts from insect cells infected with the cDNA library. Display of the two proteins in infected insect cells was shown by selective biopanning using magnetic cell sorting and demonstrated proof of concept that the baculovirus maize cDNA display library could be used to identify and isolate proteins. The maize cDNA library constructed in this study relies on the novel technology of baculovirus display and is unique in currently published cDNA libraries. Produced to demonstrate proof of principle, it opens the way for the development of a eukaryotic in vivo display tool which would be ideally suited for rapid screening of the maize proteome for binding partners, such as proteins involved in hormone regulation or defence.

  18. Comparison of high-voltage ac and pulsed operation of a surface dielectric barrier discharge

    NASA Astrophysics Data System (ADS)

    Williamson, James M.; Trump, Darryl D.; Bletzinger, Peter; Ganguly, Biswa N.

    2006-10-01

    A surface dielectric barrier discharge (DBD) in atmospheric pressure air was excited either by low frequency (0.3-2 kHz) high-voltage ac or by short, high-voltage pulses at repetition rates from 50 to 600 pulses s-1. The short-pulse excited discharge was more diffuse and did not have the pronounced bright multiple cathode spots observed in the ac excited discharge. The discharge voltage, current and average power deposited into the discharge were calculated for both types of excitation. As a measure of plasma-chemical efficiency, the ozone number density was measured by UV absorption as a function of average deposited power. The density of ozone produced by ac excitation did not increase so rapidly as that produced by short-pulse excitation as a function of average power, with a maximum measured density of ~3 × 1015 cm-3 at 25 W. The maximum ozone production achieved by short-pulse excitation was ~8.5 × 1015 cm-3 at 20 W, which was four times greater than that achieved by ac excitation at the same power level.

  19. Association of Methylenetetrahydrofolate Reductase (MTHFR 677C>T and 1298A>C) Polymorphisms and Haplotypes with Silent Brain Infarction and Homocysteine Levels in a Korean Population

    PubMed Central

    Han, In Bo; Kim, Ok Joon; Ahn, Jung Yong; Oh, Doyeun; Hong, Sun Pyo; Huh, Ryoong; Chung, Sang Sup

    2010-01-01

    Purpose Methylenetetrahydrofolate reductase (MTHFR) is the main regulatory enzyme for homocysteine metabolism. In the present study, we evaluated whether the MTHFR 677C>T and 1298A>C gene polymorphisms are associated with SBI and plasma homocysteine concentration in a Korean population. Materials and Methods We enrolled 264 patients with SBI and 234 healthy controls in South Korea. Fasting plasma total homocysteine (tHcy) concentrations were measured, and genotype analysis of the MTHFR gene was carried out. Results The plasma tHcy levels were significantly higher in patients with SBI than in healthy controls. Despite a significant association between the MTHFR 677TT genotype and hyperhomocysteinemia, the MTHFR 677C>T genotypes did not appear to influence susceptibility to SBI. However, odds ratios of the 1298AC and 1298AC + CC genotypes for the 1298AA genotype were significantly different between SBI patients and normal controls. The frequencies of 677C-1298A and 677C-1298C haplotypes were significantly higher in the SBI group than in the control group. Conclusion This study demonstrates that the MTHFR 1298A>C polymorphism is a risk factor for SBI in a Korean population. The genotypes of 677C>T and 1298A>C polymorphisms interact additively, and increase the risk of SBI in Korean subjects. PMID:20191019

  20. Multifunction display system, volume 1

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The design and construction of a multifunction display man/machine interface for use with a 4 pi IBM-360 System are described. The system is capable of displaying superimposed volatile alphanumeric and graphical data on a 512 x 512 element plasma panel, and holographically stored multicolor archival information. The volatile data may be entered from a keyboard or by means of an I/O interface to the 360 system. A 2-page memory local to the display is provided for storing the entered data. The archival data is stored as a phase hologram on a vinyl tape strip. This data is accessible by means of a rapid transport system which responds to inputs provided by the I/O channel on the keyboard. As many as 500 frames may be stored on a tape strip for access in under 6 seconds.

  1. A novel emissive projection display (EPD) on transparent phosphor screen

    NASA Astrophysics Data System (ADS)

    Cheng, Botao; Sun, Leonard; Yu, Ge; Sun, Ted X.

    2017-03-01

    A new paradigm of digital projection is on the horizon, based on innovative emissive screen that are made fully transparent. It can be readily applied and convert any surface to a high image quality emissive digital display, without affecting the surface appearance. For example, it can convert any glass window or windshield to completely see-through display, with unlimited field of view and viewing angles. It also enables a scalable and economic projection display on a pitch-black emissive screen with black level and image contrast that rivals other emissive displays such as plasma display or OLED.

  2. Low Offset AC Correlator.

    DTIC Science & Technology

    This patent describes a low offset AC correlator avoids DC offset and low frequency noise by frequency operating the correlation signal so that low...noise, low level AC amplification can be substituted for DC amplification. Subsequently, the high level AC signal is demodulated to a DC level. (Author)

  3. Alternating current (AC) iontophoretic transport across human epidermal membrane: effects of AC frequency and amplitude.

    PubMed

    Yan, Guang; Xu, Qingfang; Anissimov, Yuri G; Hao, Jinsong; Higuchi, William I; Li, S Kevin

    2008-03-01

    As a continuing effort to understand the mechanisms of alternating current (AC) transdermal iontophoresis and the iontophoretic transport pathways in the stratum corneum (SC), the objectives of the present study were to determine the interplay of AC frequency, AC voltage, and iontophoretic transport of ionic and neutral permeants across human epidermal membrane (HEM) and use AC as a means to characterize the transport pathways. Constant AC voltage iontophoresis experiments were conducted with HEM in 0.10 M tetraethyl ammonium pivalate (TEAP). AC frequencies ranging from 0.0001 to 25 Hz and AC applied voltages of 0.5 and 2.5 V were investigated. Tetraethyl ammonium (TEA) and arabinose (ARA) were the ionic and neutral model permeants, respectively. In data analysis, the logarithm of the permeability coefficients of HEM for the model permeants was plotted against the logarithm of the HEM electrical resistance for each AC condition. As expected, linear correlations between the logarithms of permeability coefficients and the logarithms of resistances of HEM were observed, and the permeability data were first normalized and then compared at the same HEM electrical resistance using these correlations. Transport enhancement of the ionic permeant was significantly larger than that of the neutral permeant during AC iontophoresis. The fluxes of the ionic permeant during AC iontophoresis of 2.5 V in the frequency range from 5 to 1,000 Hz were relatively constant and were approximately 4 times over those of passive transport. When the AC frequency decreased from 5 to 0.001 Hz at 2.5 V, flux enhancement increased to around 50 times over passive transport. While the AC frequency for achieving the full effect of iontophoretic enhancement at low AC frequency was lower than anticipated, the frequency for approaching passive diffusion transport at high frequency was higher than expected from the HEM morphology. These observations are consistent with a transport model of multiple

  4. Electron Temperature and Plasma Flow Measurements of NIF Hohlraum Plasmas

    NASA Astrophysics Data System (ADS)

    Barrios, M. A.; Liedahl, D. A.; Schneider, M. B.; Jones, O.; Brow, G. V.; Regan, S. P.; Fournier, K. B.; Moore, A. S.; Ross, J. S.; Eder, D.; Landen, O.; Kauffman, R. L.; Nikroo, A.; Kroll, J.; Jaquez, J.; Huang, H.; Hansen, S. B.; Callahan, D. A.; Hinkel, D. E.; Bradley, D.; Moody, J. D.; LLNL Collaboration; LLE Collaboration; GA Collaboration; SNL Collaboration

    2016-10-01

    Characterizing the plasma conditions inside NIF hohlraums, in particular mapping the plasma Te, is critical to gaining insight into mechanisms that affect energy coupling and transport in the hohlraum. The dot spectroscopy platform provides a temporal history of the localized Te and plasma flow inside a NIF hohlraum, by introducing a Mn-Co tracer dot, at strategic locations inside the hohlraum, that comes to equilibrium with the local plasma. K-shell X-ray spectroscopy of the tracer dot is recorded onto an absolutely calibrated X-ray streak spectrometer. Isoelectronic and interstage line ratios are used to infer localized Te through comparison with atomic physics calculations using SCRAM. Time resolved X-ray images are simultaneously taken of the expanding dot, providing plasma (ion) flow information. We present recent results provided by this platform and compare with simulations using HYDRA. This work was performed under the auspices of the U.S. Department of Energy by LLNL under Contract DE-AC52-07NA27344.

  5. An 11 cm long atmospheric pressure cold plasma plume for applications of plasma medicine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu Xinpei; Jiang Zhonghe; Xiong Qing

    2008-02-25

    In this letter, a room temperature atmospheric pressure plasma jet device is reported. The high voltage electrode of the device is covered by a quartz tube with one end closed. The device, which is driven by a kilohertz ac power supply, is capable of generating a plasma plume up to 11 cm long in the surrounding room air. The rotational and vibrational temperatures of the plasma plume are 300 and 2300 K, respectively. A simple electrical model shows that, when the plasma plume is contacted with a human, the voltage drop on the human is less than 66 V formore » applied voltage of 5 kV (rms)« less

  6. Polymorphisms, de novo lipogenesis, and plasma triglyceride response following fish oil supplementation

    PubMed Central

    Bouchard-Mercier, Annie; Rudkowska, Iwona; Lemieux, Simone; Couture, Patrick; Vohl, Marie-Claude

    2013-01-01

    Interindividual variability in the response of plasma triglyceride concentrations (TG) following fish oil consumption has been observed. Our objective was to examine the associations between single-nucleotide polymorphisms (SNPs) within genes encoding proteins involved in de novo lipogenesis and the relative change in plasma TG levels following a fish oil supplementation. Two hundred and eight participants were recruited in the greater Quebec City area. The participants completed a six-week fish oil supplementation (5 g fish oil/day: 1.9–2.2 g eicosapentaenoic acid and 1.1 g docosahexaenoic acid. SNPs within SREBF1, ACLY, and ACACA genes were genotyped using TAQMAN methodology. After correction for multiple comparison, only two SNPs, rs8071753 (ACLY) and rs1714987 (ACACA), were associated with the relative change in plasma TG concentrations (P = 0.004 and P = 0.005, respectively). These two SNPs explained 7.73% of the variance in plasma TG relative change following fish oil consumption. Genotype frequencies of rs8071753 according to the TG response groups (responders versus nonresponders) were different (P = 0.02). We conclude that the presence of certain SNPs within genes, such as ACLY and ACACA, encoding proteins involved in de novo lipogenesis seem to influence the plasma TG response following fish oil consumption. PMID:23886516

  7. Polymorphisms, de novo lipogenesis, and plasma triglyceride response following fish oil supplementation.

    PubMed

    Bouchard-Mercier, Annie; Rudkowska, Iwona; Lemieux, Simone; Couture, Patrick; Vohl, Marie-Claude

    2013-10-01

    Interindividual variability in the response of plasma triglyceride concentrations (TG) following fish oil consumption has been observed. Our objective was to examine the associations between single-nucleotide polymorphisms (SNPs) within genes encoding proteins involved in de novo lipogenesis and the relative change in plasma TG levels following a fish oil supplementation. Two hundred and eight participants were recruited in the greater Quebec City area. The participants completed a six-week fish oil supplementation (5 g fish oil/day: 1.9-2.2 g eicosapentaenoic acid and 1.1 g docosahexaenoic acid. SNPs within SREBF1, ACLY, and ACACA genes were genotyped using TAQMAN methodology. After correction for multiple comparison, only two SNPs, rs8071753 (ACLY) and rs1714987 (ACACA), were associated with the relative change in plasma TG concentrations (P = 0.004 and P = 0.005, respectively). These two SNPs explained 7.73% of the variance in plasma TG relative change following fish oil consumption. Genotype frequencies of rs8071753 according to the TG response groups (responders versus nonresponders) were different (P = 0.02). We conclude that the presence of certain SNPs within genes, such as ACLY and ACACA, encoding proteins involved in de novo lipogenesis seem to influence the plasma TG response following fish oil consumption.

  8. Synthesis and plasma pharmacokinetics in CD-1 mice of a 18β-glycyrrhetinic acid derivative displaying anti-cancer activity.

    PubMed

    Lallemand, Benjamin; Ouedraogo, Moustapha; Wauthoz, Nathalie; Lamkami, Touria; Mathieu, Veronique; Jabin, Ivan; Amighi, Karim; Kiss, Robert; Dubois, Jacques; Goole, Jonathan

    2013-03-01

    The plasma pharmacokinetic profile in CD-1 mice of a novel 18β-glycyrrhetinic acid (GA) derivative, which displays in vitro anti-cancer activity, was assessed. This study involved an original one-step synthesis of N-(2-{3-[3,5-bis(trifluoromethyl)phenyl]ureido}ethyl)-glycyrrhetinamide, (2) a compound that displays marked anti-proteasome and anti-kinase activity. The bioselectivity profile of 2 on human normal NHDF fibroblasts vs human U373 glioblastoma cells was assessed. Maximal tolerated dose (MTD) profiling of 2 was carried out in CD1 mice, and its serum pharmacokinetics were profiled using an acute intravenous administration of 40 mg/kg body weight. Compound 2 displayed IC(50) in vitro growth inhibitory concentrations of 29 and 8 μm on NHDF fibroblasts and U373 glioblastoma cells, respectively, thus a bioselectivity index of ∼4. The intravenous pharmacokinetic parameters revealed that 2 was rapidly distributed (t(1/2dist) of ∼3 min) but slowly eliminated (t(1/2elim)  = ∼77 min). This study describes an original and reliable nanoemulsion of a GA derivative with both anti-proteasome and anti-kinase properties and that should be further tested in vivo using various human xenograft or murine syngeneic tumour models with both single and chronic intravenous administration. © 2012 The Authors. JPP © 2012. Royal Pharmaceutical Society.

  9. Technical trends of large-size photomasks for flat panel displays

    NASA Astrophysics Data System (ADS)

    Yoshida, Koichiro

    2017-06-01

    Currently, flat panel displays (FPDs) are one of the main parts for information technology devices and sets. From 1990's to 2000's, liquid crystal displays (LCDs) and plasma displays had been mainstream FPDs. In the middle of 2000's, demand of plasma displays declined and organic light emitting diodes (OLEDs) newly came into FPD market. And today, major technology of FPDs are LCDs and OLEDs. Especially for mobile devices, the penetration of OLEDs is remarkable. In FPDs panel production, photolithography is the key technology as same as LSI. Photomasks for FPDs are used not only as original master of circuit pattern, but also as a tool to form other functional structures of FPDs. Photomasks for FPDs are called as "Large Size Photomasks(LSPMs)", since the remarkable feature is " Size" which reaches over 1- meter square and over 100kg. In this report, we discuss three LSPMs technical topics with FPDs technical transition and trend. The first topics is upsizing of LSPMs, the second is the challenge for higher resolution patterning, and the last is "Multi-Tone Mask" for "Half -Tone Exposure".

  10. HPLC analysis of para-aminosalicylic acid and its metabolite in plasma, cerebrospinal fluid and brain tissues

    PubMed Central

    Hong, Lan; Jiang, Wendy; Zheng, Wei; Zeng, Su

    2011-01-01

    Para-aminosalicylic acid (PAS), an approved drug for treatment of tuberculosis, is a promising therapeutic agent for treatment of manganese (Mn)-induced parkinsonian syndromes. Lack of a quantifying method, however, has hindered the clinical evaluation of its efficacy and thereupon new drug development. This study was aimed at developing a simple and effective method to quantify PAS and its major metabolite, N-acetyl-para-aminosalicylic acid (AcPAS), in plasma, cerebrospinal fluid (CSF) and tissues. Biological samples underwent one-step protein precipitation. The supernatant was fractionated on a reversed-phase C18 column with a gradient mobile system, followed by on-line fluorescence detection. The lower limits of quantification for both PAS and AcPAS were 50 ng/ml of plasma and 17 ng/g of tissues. The intra-day and inter-day precision values did not exceed 5% and 8%, respectively, in all three matrices. The method was used to quantify PAS and AcPAS in rat plasma and brain following a single iv injection of PAS. Data showed a greater amount of PAS than AcPAS in plasma, while a greater amount of AcPAS than PAS was found in brain tissues. The method has been proven to be sensitive, reproducible, and practically useful for laboratory and clinical investigations of PAS in treatment of Mn Parkinsonism. PMID:21159459

  11. Effects of ramp reset pulses on the address discharge in a shadow mask plasma display panel

    NASA Astrophysics Data System (ADS)

    Yang, Lanlan; Tu, Yan; Zhang, Xiong; Jiang, Youyan; Zhang, Jian; Wang, Baoping

    2007-05-01

    A two-dimensional self-consistent numerical simulation model is used to analyse the effects of the ramp reset pulses on the address discharge in a shadow mask plasma display panel (SM-PDP). Some basic parameters such as the slope of the ramp pulse and the terminal voltage of the ramp reset period are varied to investigate their effects. The simulation results illustrate that the wall voltage is mainly decided by the terminal voltage and the firing voltage at the end of the ramp reset period. Moreover, the variation of the ramp slope will also bring a few modifications to the wall voltage. The priming particles in the beginning of the addressing period are related to the slope of the ramping down voltage pulse. The simulation results can help us optimize the driving scheme of the SM-PDP.

  12. Power density measurements to optimize AC plasma jet operation in blood coagulation.

    PubMed

    Ahmed, Kamal M; Eldeighdye, Shaimaa M; Allam, Tarek M; Hassanin, Walaa F

    2018-06-14

    In this paper, the plasma power density and corresponding plasma dose of a low-cost air non-thermal plasma jet (ANPJ) device are estimated at different axial distances from the nozzle. This estimation is achieved by measuring the voltage and current at the substrate using diagnostic techniques that can be easily made in laboratory; thin wire and dielectric probe, respectively. This device uses a compressed air as input gas instead of the relatively-expensive, large-sized and heavy weighed tanks of Ar or He gases. The calculated plasma dose is found to be very low and allows the presented device to be used in biomedical applications (especially blood coagulation). While plasma active species and charged-particles are found to be the most effective on blood coagulation formation, both air flow and UV, individually, do not have any effect. Moreover, optimal conditions for accelerating blood coagulation are studied. Results showed that, the power density at the substrate is shown to be decreased with increasing the distance from the nozzle. In addition, both distances from nozzle and air flow rate play an important role in accelerating blood coagulation process. Finally, this device is efficient, small-sized, safe enough, of low cost and, hence, has its chances to be wide spread as a first aid and in ambulance.

  13. A study of 173 nm light emission from discharge cells in plasma display panel

    NASA Astrophysics Data System (ADS)

    Uhm, Han S.; Choi, Eun H.; Jung, Kyu B.

    2005-03-01

    Emission properties of the 173nm lights from the electrical discharge cells of the plasma display panel are investigated. The dimer formation and a theoretical model of 173nm emission are presented. It is shown that the diffusion loss of the excited xenon atoms in the metastable level is one of the most important population depreciation factor of excited xenon atoms. The decay time τd of excited atom number increases from zero, reaches its peak, and then decreases to zero, as the gas pressure p increases from zero, agreeing well with experimental data. A simple analytical expression Y of the total emission intensity is described in terms of the diffusion loss df, the three-body collision η, the gas pressure p, and the xenon mole fraction χ. The emission intensity Y of 173nm photon decreases with an increasing value of parameter df. Moreover, the emission intensity Y increases drastically with an increasing value of the gas pressure p and the xenon mole fraction χ. Results from the theoretical model agree remarkably well with experimental data.

  14. The TV Turtle: A LOGO Graphics System for Raster Displays. AI Memo 361.

    ERIC Educational Resources Information Center

    Lieberman, Henry

    This discussion of the advantages and limitations of raster graphics systems points out that until recently, most computer graphics systems have been oriented toward the display of line drawings, continually refreshing the screen from a display list of vectors. Developments such as plasma panel displays and rapidly declining memory prices have now…

  15. FLUIDIC AC AMPLIFIERS.

    DTIC Science & Technology

    Several fluidic tuned AC Amplifiers were designed and tested. Interstage tuning and feedback designs are considered. Good results were obtained...corresponding Q’s as high as 12. Element designs and test results of one, two, and three stage amplifiers are presented. AC Modulated Carrier Systems

  16. Investigation on discharge characteristics of a coaxial dielectric barrier discharge reactor driven by AC and ns power sources

    NASA Astrophysics Data System (ADS)

    Qian, WANG; Feng, LIU; Chuanrun, MIAO; Bing, YAN; Zhi, FANG

    2018-03-01

    A coaxial dielectric barrier discharge (DBD) reactor with double layer dielectric barriers has been developed for exhaust gas treatment and excited either by AC power or nanosecond (ns) pulse to generate atmospheric pressure plasma. The comparative study on the discharge characteristics of the discharge uniformity, power deposition, energy efficiency, and operation temperature between AC and ns pulsed coaxial DBD is carried out in terms of optical and electrical characteristics and operation temperature for optimizing the coaxial DBD reactor performance. The voltages across the air gap and dielectric layer and the conduction and displacement currents are extracted from the applied voltages and measured currents of AC and ns pulsed coaxial DBDs for the calculation of the power depositions and energy efficiencies through an equivalent electrical model. The discharge uniformity and operating temperature of the coaxial DBD reactor are monitored and analyzed by optical images and infrared camera. A heat conduction model is used to calculate the temperature of the internal quartz tube. It is found that the ns pulsed coaxial DBD has a much higher instantaneous power deposition in plasma, a lower total power consumption, and a higher energy efficiency compared with that excited by AC power and is more homogeneous and stable. The temperature of the outside wall of the AC and ns pulse excited coaxial DBD reaches 158 °C and 64.3 °C after 900 s operation, respectively. The experimental results on the comparison of the discharge characteristics of coaxial DBDs excited by different powers are significant for understanding of the mechanism of DBDs, reducing energy loss, and optimizing the performance of coaxial DBD in industrial applications.

  17. Measurement of low temperature plasma properties using non-invasive impedance measurements

    NASA Astrophysics Data System (ADS)

    Gillman, Eric; Amatucci, Bill; Tejero, Erik; Blackwell, David

    2017-10-01

    A plasma discharge can be modeled electrically as a combination of capacitors, resistors, and inductors. The plasma, much like an RLC circuit, will have resonances at particular frequencies. The location in frequency space of these resonances provides information about the plasma parameters. These resonances can be detected using impedance measurements, where the AC impedance of the plasma is measured by sweeping the frequency of an AC voltage applied to a sensor and determining the magnitude and phase of the measured current. In this work, an electrode used to sustain a glow discharge is also used as an impedance probe. The novelty of this method is that insertion of a physical probe, which can introduce perturbation and/or contamination, is not necessary. This non-invasive impedance probe method is used to measure the plasma discharge density in various regimes of plasma operation. Experimental results are compared to the basic circuit model results. The potential applications of this diagnostic method and regimes over which this measurement method is valid will be discussed.

  18. Development of a hardware-based AC microgrid for AC stability assessment

    NASA Astrophysics Data System (ADS)

    Swanson, Robert R.

    As more power electronic-based devices enable the development of high-bandwidth AC microgrids, the topic of microgrid power distribution stability has become of increased interest. Recently, researchers have proposed a relatively straightforward method to assess the stability of AC systems based upon the time-constants of sources, the net bus capacitance, and the rate limits of sources. In this research, a focus has been to develop a hardware test system to evaluate AC system stability. As a first step, a time domain model of a two converter microgrid was established in which a three phase inverter acts as a power source and an active rectifier serves as an adjustable constant power AC load. The constant power load can be utilized to create rapid power flow transients to the generating system. As a second step, the inverter and active rectifier were designed using a Smart Power Module IGBT for switching and an embedded microcontroller as a processor for algorithm implementation. The inverter and active rectifier were designed to operate simultaneously using a synchronization signal to ensure each respective local controller operates in a common reference frame. Finally, the physical system was created and initial testing performed to validate the hardware functionality as a variable amplitude and variable frequency AC system.

  19. An experimental study of icing control using DBD plasma actuator

    NASA Astrophysics Data System (ADS)

    Cai, Jinsheng; Tian, Yongqiang; Meng, Xuanshi; Han, Xuzhao; Zhang, Duo; Hu, Haiyang

    2017-08-01

    Ice accretion on aircraft or wind turbine has been widely recognized as a big safety threat in the past decades. This study aims to develop a new approach for icing control using an AC-DBD plasma actuator. The experiments of icing control (i.e., anti-/de-icing) on a cylinder model were conducted in an icing wind tunnel with controlled wind speed (i.e., 15 m/s) and temperature (i.e., -10°C). A digital camera was used to record the dynamic processes of plasma anti-icing and de-icing whilst an infrared imaging system was utilized to map the surface temperature variations during the anti-/de-icing processes. It was found that the AC-DBD plasma actuator is very effective in both anti-icing and de-icing operations. While no ice formation was observed when the plasma actuator served as an anti-icing device, a complete removal of the ice layer with a thickness of 5 mm was achieved by activating the plasma actuator for ˜150 s. Such information demonstrated the feasibility of plasma anti-/de-icing, which could potentially provide more effective and safer icing mitigation strategies.

  20. The Effects of Angiotensin Converting Enzyme Inhibitors (ACE-I) on Human N-Acetyl-Seryl-Aspartyl-Lysyl-Proline (Ac-SDKP) Levels: A Systematic Review and Meta-Analysis.

    PubMed

    Mnguni, Ayanda Trevor; Engel, Mark E; Borkum, Megan S; Mayosi, Bongani M

    2015-01-01

    Tuberculous pericardial effusion is a pro-fibrotic condition that is complicated by constrictive pericarditis in 4% to 8% of cases. N-acetyl-seryl-aspartyl-lysyl-proline (Ac-SDKP) is a ubiquitous tetrapeptide with anti-fibrotic properties that is low in tuberculous pericardial effusion, thus providing a potential mechanism for the heightened fibrotic state. Angiotensin-converting enzyme inhibitors (ACE-I), which increase Ac-SDKP levels with anti-fibrotic effects in animal models, are candidate drugs for preventing constrictive pericarditis if they can be shown to have similar effects on Ac-SDKP and fibrosis in human tissues. To systematically review the effects of ACE-Is on Ac-SDKP levels in human tissues. We searched five electronic databases (1996 to 2014) and conference abstracts with no language restrictions. Two reviewers independently selected studies, extracted data and assessed methodological quality. The protocol was registered in PROSPERO. Four studies with a total of 206 participants met the inclusion criteria. Three studies (106 participants) assessed the change in plasma levels of Ac-SDKP following ACE-I administration in healthy humans. The administration of an ACE-I was associated with an increase in Ac-SDKP levels (mean difference (MD) 5.07 pmol/ml (95% confidence intervals (CI) 0.64 pmol/ml to 9.51 pmol/ml)). Two studies with 100 participants further assessed the change in Ac-SDKP level in humans with renal failure using ACE-I. The administration of an ACE-I was associated with a significant increase in Ac-SDKP levels (MD 8.94 pmol/ml; 95% CI 2.55 to 15.33; I2 = 44%). ACE-I increased Ac-SDKP levels in human plasma. These findings provide the rationale for testing the impact of ACE-I on Ac-SDKP levels and fibrosis in tuberculous pericarditis.

  1. Two Distinctive Phenotypes of AcMNPV Display Different Immune Abilities and Intracellular Destiny.

    PubMed

    Molina, Guido N; Tavarone, Eugenia; Taboga, Oscar; Molinari, Paula

    2016-01-01

    The budded phenotype (BV) of the baculovirus AcMNPV has been demonstrated to have strong immunostimulatory properties that are relevant for the development of vaccines and antiviral therapies. Although the occluded phenotype (ODV) shares the main structural proteins and its genome with BV, it has been poorly studied in mammals. In this study, we assessed the capacity of ODV to induce immune responses in mice. In contrast to BVs, ODVs failed to promote the secretion of IFN-gamma, IL-6 and Il-12 and to induce antiviral activity against VSV in the short term. Furthermore, ODVs were unable to induce cellular immunity against a coadministered antigen 7 days after inoculation. By analyzing the interaction of ODVs with BMDCs, we observed that although ODVs entered the cells reaching late and acidic endosomes, they did not induce their maturation. Finally, we also analyzed if BVs and ODVs followed different routes in the cell during the infection. BVs, but not ODVs, colocalized with the protein ovalbumin in compartments with the presence of proteases. The results suggest that structural differences could be responsible for their different destinies in the dendritic cell and this could lead to a different impact on the immune response.

  2. Performance trends of rehabilitated AC pavements

    DOT National Transportation Integrated Search

    2000-10-01

    The General Pavement Study (GPS) 6 experiment, "AC Overlay of AC Pavements," involves pavement test sections where an asphalt concrete (AC) overlay was placed on an existing AC pavement. This TechBrief summarizes the results of a study of the GPS-6 e...

  3. A new AC driving circuit for a top emission AMOLED

    NASA Astrophysics Data System (ADS)

    Yongwen, Zhang; Wenbin, Chen; Haohan, Liu

    2013-05-01

    A new voltage programmed pixel circuit with top emission design for active-matrix organic light-emitting diode (AMOLED) displays is presented and verified by HSPICE simulations. The proposed pixel circuit consists of five poly-Si TFTs, and can effectively compensate for the threshold voltage variation of the driving TFT. Meanwhile, the proposed pixel circuit offers an AC driving mode for the OLED by the two adjacent pulse voltage sources, which can suppress the degradation of the OLED. Moreover, a high contrast ratio can be achieved by the proposed pixel circuit since the OLED does not emit any light except for the emission period.

  4. Status review of field emission displays

    NASA Astrophysics Data System (ADS)

    Ghrayeb, Joseph; Daniels, Reginald

    2001-09-01

    Cathode ray tube (CRT) technology dominates the direct view display market. Mature CRT technology for many designs is still the preferred choice. CRT manufacturers have greatly improved the size and weight of the CRT displays. High performance CRTs continue to be in great demand, however, supply have to contend with the vanishing CRT vendor syndrome. Therefore, the vanishing CRT vendor syndrome fuels the search for an alternate display technology source. Within the past 10 years, field emission display (FED) technology had gained momentum and, at one time, was considered the most viable electronic display technology candidate [to replace the CRT]. The FED community had advocated and promised many advantages over active matrix liquid crystal displays (AMLCD), electro luminescent (EL) or Plasma displays. Some observers, including potential FED manufacturers and the Department of Defense, (especially the Defense Advanced Research Project Agency (DARPA)), consider the FED entry as having leapfrog potential. Despite major investments by US manufacturers as well as Asian manufacturers, reliability and manufacturing difficulties greatly slowed down the advancement of the technology. The FED manufacturing difficulties have caused many would-be FED manufacturing participants to abandon FED research. This paper will examine the trends, which are leading this nascent technology to its downfall. FED technology was once considered to have the potential to leapfrog over AMLCD's dominance in the display industry. At present the FED has suffered severe setbacks and there are very few [FED] manufacturers still pursuing research in the area. These companies have yet to deliver a display beyond the prototype stage.

  5. Dependence of SOL widths on plasma parameters in NSTX

    NASA Astrophysics Data System (ADS)

    Ahn, Joon-Wook; Maingi, Rajesh; Boedo, Jose; Soukhanovskii, Vlad; Leblanc, Ben; Kaita, Robert

    2008-11-01

    The dependence of various upstream Scrape-Off Layer (SOL) widths on the line-averaged density (n e), plasma current (Ip), and power into the SOL (PSOL) for H-mode plasmas was investigated, using the mid-plane fast reciprocating probe and Thomson scattering diagnostics, in the National Spherical Torus Experiment (NSTX). The heat flux width (λq) at the divertor plate, measured by the IR camera, was also measured and compared with the upstream SOL widths. The edge density profile remains fixed during the H-mode, such that the separatrix density is constant even though n e is ramping. Thus λq, λTe, and λne are insensitive to n e. λTe and λjsat have strong negative dependence on Ip, whereas there was only a very weak change in λne when Ip was varied. These empirical results have been compared with scaling laws in the literature. The λTe dependence on Ip is consistent with an H-mode λTe scaling law, while the insensitivity of λne to n e is not consistent with the λne scaling law. Dependence of decay lengths on plasma parameters in a wide range of plasma conditions will be presented. This work was supported by the US Department of Energy, contract numbers DE-FG02-03ER54731, DE-AC02-76CH03073, DE-AC05-00OR22725, and DE-AC52-07NA27344.

  6. Integration issues of a plasma contactor Power Electronics Unit

    NASA Technical Reports Server (NTRS)

    Pinero, Luis R.; York, Kenneth W.; Bowers, Glen E.

    1995-01-01

    A hollow cathode-based plasma contactor is baselined on International Space Station Alpha (ISSA) for spacecraft charge control. The plasma contactor system consists of a hollow cathode assembly (HCA), a power electronics unit (PEU), and an expellant management unit (EMU). The plasma contactor has recently been required to operate in a cyclic mode to conserve xenon expellant and extend system life. Originally, a DC cathode heater converter was baselined for a continuous operation mode because only a few ignitions of the hollow cathode were expected. However, for cyclic operation, a DC heater supply can potentially result in hollow cathode heater component failure due to the DC electrostatic field. This can prevent the heater from attaining the proper cathode tip temperature for reliable ignition of the hollow cathode. To mitigate this problem, an AC cathode heater supply was therefore designed, fabricated, and installed into a modified PEU. The PEU was tested using resistive loads and then integrated with an engineering model hollow cathode to demonstrate stable steady-state operation. Integration issues such as the effect of line and load impedance on the output of the AC cathode heater supply and the characterization of the temperature profile of the heater under AC excitation were investigated.

  7. Estimating BrAC from transdermal alcohol concentration data using the BrAC estimator software program.

    PubMed

    Luczak, Susan E; Rosen, I Gary

    2014-08-01

    Transdermal alcohol sensor (TAS) devices have the potential to allow researchers and clinicians to unobtrusively collect naturalistic drinking data for weeks at a time, but the transdermal alcohol concentration (TAC) data these devices produce do not consistently correspond with breath alcohol concentration (BrAC) data. We present and test the BrAC Estimator software, a program designed to produce individualized estimates of BrAC from TAC data by fitting mathematical models to a specific person wearing a specific TAS device. Two TAS devices were worn simultaneously by 1 participant for 18 days. The trial began with a laboratory alcohol session to calibrate the model and was followed by a field trial with 10 drinking episodes. Model parameter estimates and fit indices were compared across drinking episodes to examine the calibration phase of the software. Software-generated estimates of peak BrAC, time of peak BrAC, and area under the BrAC curve were compared with breath analyzer data to examine the estimation phase of the software. In this single-subject design with breath analyzer peak BrAC scores ranging from 0.013 to 0.057, the software created consistent models for the 2 TAS devices, despite differences in raw TAC data, and was able to compensate for the attenuation of peak BrAC and latency of the time of peak BrAC that are typically observed in TAC data. This software program represents an important initial step for making it possible for non mathematician researchers and clinicians to obtain estimates of BrAC from TAC data in naturalistic drinking environments. Future research with more participants and greater variation in alcohol consumption levels and patterns, as well as examination of gain scheduling calibration procedures and nonlinear models of diffusion, will help to determine how precise these software models can become. Copyright © 2014 by the Research Society on Alcoholism.

  8. AC/RC Force Integration

    DTIC Science & Technology

    1991-05-01

    ib qeocie. Thki document may not be rdeaed for open publicado. untit hu been deared by die appropriate military seavice or a veunent agency. AC /RC...A N/A N/A 11. TITLE (Include Security Classification) AC /RC Force Structure Integraticn 12. PERSONAL AUTHOR(S) Russell A. Eggers 13a. TYPE OF REPORT... AC ) and Reserve Components (RC) Force Integration is critical in today’s Total Army. The Army of soldiers, Active and Reserve, exists to play a key

  9. The Staphylococcus aureus Two-Component System AgrAC Displays Four Distinct Genomic Arrangements That Delineate Genomic Virulence Factor Signatures

    PubMed Central

    Choudhary, Kumari S.; Mih, Nathan; Monk, Jonathan; Kavvas, Erol; Yurkovich, James T.; Sakoulas, George; Palsson, Bernhard O.

    2018-01-01

    Two-component systems (TCSs) consist of a histidine kinase and a response regulator. Here, we evaluated the conservation of the AgrAC TCS among 149 completely sequenced Staphylococcus aureus strains. It is composed of four genes: agrBDCA. We found that: (i) AgrAC system (agr) was found in all but one of the 149 strains, (ii) the agr positive strains were further classified into four agr types based on AgrD protein sequences, (iii) the four agr types not only specified the chromosomal arrangement of the agr genes but also the sequence divergence of AgrC histidine kinase protein, which confers signal specificity, (iv) the sequence divergence was reflected in distinct structural properties especially in the transmembrane region and second extracellular binding domain, and (v) there was a strong correlation between the agr type and the virulence genomic profile of the organism. Taken together, these results demonstrate that bioinformatic analysis of the agr locus leads to a classification system that correlates with the presence of virulence factors and protein structural properties. PMID:29887846

  10. On behavior peculiarity of electron plasma

    NASA Astrophysics Data System (ADS)

    Gordeeva, N. M.; Yushkanov, A. A.

    2018-03-01

    The analysis of the analytical solution of the problem of the behavior of electron plasma in the AC electric field is fulfilled. Debye mode describes shielding of the external electric field in the plasma. The analysis of the region of existence of Debye mode, depending on the plasma parameters has been realized. A non-trivial dependence of the region of existence of Debye mode on the degree of degeneracy of the electron gas are revealed. For the case of nearly degenerate electron gas Debye mode has several areas of existence, depending on the frequency of the electric field.

  11. Characterizing fiber-reinforced composite structures using AC-impedance spectroscopy (AC-IS)

    NASA Astrophysics Data System (ADS)

    Woo, Leta Y.

    Property enhancement in composites depends largely on the reinforcement. For fiber-reinforced composites, the distribution of fibers is crucial in determining the electrical and mechanical performance. Image analysis methods for characterization can be time-consuming and/or destructive. This work explores the capability of AC-impedance spectroscopy (AC-IS), an electrical measurement technique, to serve as a rapid, non-destructive tool for characterizing composite microstructure. The composite requirements include a filler that is electrically conducting or semi-conducting with higher conductivity than the matrix, and a high-impedance interface or coating between the filler and the matrix. To establish an AC-IS characterization method, cement-matrix composites with steel reinforcement were employed as both a technologically important and a model system to investigate how fibers affect the electrical response. Beginning with spherical particulates and then fibers, composites were examined using composite theory and an "intrinsic conductivity" approach. The intrinsic conductivity approach applies to composites with low volume fractions of fibers (i.e., in the dilute regime) and relates how the composite conductivity varies relative to the matrix as a function of volume fraction. A universal equivalent circuit model was created to understand the AC-IS response of composites based on the geometry and volume fraction of the filler. Deviation from predicted behavior was assessed using a developed f-function, which quantifies how fibers contribute to the overall electrical response of the composite. Using the f-function, an AC-IS method for investigating fiber dispersion was established to characterize alignment, settling/segregation, and aggregation. Alignment was investigated using measurements made in three directions. A point-probe technique characterized settling and/or large-scale inhomogeneous mixing in samples. Aggregation was quantified using a "dispersion factor

  12. Absorption and Attenuation Coefficients Using the WET Labs ac-s in the Mid-Atlantic Bight: Field Measurements and Data Analysis

    NASA Technical Reports Server (NTRS)

    Ohi, Nobuaki; Makinen, Carla P.; Mitchell, Richard; Moisan, Tiffany A.

    2008-01-01

    Ocean color algorithms are based on the parameterization of apparent optical properties as a function of inherent optical properties. WET Labs underwater absorption and attenuation meters (ac-9 and ac-s) measure both the spectral beam attenuation [c (lambda)] and absorption coefficient [a (lambda)]. The ac-s reports in a continuous range of 390-750 nm with a band pass of 4 nm, totaling approximately 83 distinct wavelengths, while the ac-9 reports at 9 wavelengths. We performed the ac-s field measurements at nine stations in the Mid-Atlantic Bight from water calibrations to data analysis. Onboard the ship, the ac-s was calibrated daily using Milli Q-water. Corrections for the in situ temperature and salinity effects on optical properties of water were applied. Corrections for incomplete recovery of the scattered light in the ac-s absorption tube were performed. The fine scale of spectral and vertical distributions of c (lambda) and a (lambda) were described from the ac-s. The significant relationships between a (674) and that of spectrophotometric analysis and chlorophyll a concentration of discrete water samples were observed.

  13. Twisting Plasma

    NASA Image and Video Library

    2016-06-08

    A close-up of twisting plasma above the Sun's surface produced a nice display of turbulence by caused combative magnetic forces (June 7-8, 2016) over a day and a half. The plasma does not break away, but just spins and twists the entire period. Images were taken in extreme ultraviolet light. The mass we observed is part of a longer, darkish filament angling down from the upper left of the frame. Filaments are unstable clouds of plasma suspended above the Sun by magnetic forces. http://photojournal.jpl.nasa.gov/catalog/PIA20739

  14. Measurement of luminance and color uniformity of displays using the large-format scanner

    NASA Astrophysics Data System (ADS)

    Mazikowski, Adam

    2017-08-01

    Uniformity of display luminance and color is important for comfort and good perception of the information presented on the display. Although display technology has developed and improved a lot over the past years, different types of displays still present a challenge in selected applications, e.g. in medical use or in case of multi-screen installations. A simplified 9-point method of determining uniformity does not always produce satisfactory results, so a different solution is proposed in the paper. The developed system consists of the large-format X-Y-Z ISEL scanner (isel Germany AG), Konica Minolta high sensitivity spot photometer-colorimeter (e.g. CS-200, Konica Minolta, Inc.) and PC computer. Dedicated software in LabView environment for control of the scanner, transfer the measured data to the computer, and visualization of measurement results was also prepared. Based on the developed setup measurements of plasma display and LCD-LED display were performed. A heavily wornout plasma TV unit, with several artifacts visible was selected. These tests show the advantages and drawbacks of described scanning method with comparison with 9-point simplified uniformity determining method.

  15. Hazardous and Medical Waste Destruction Using the AC Plasmatron Final Report CRADA No. TC-1560-98

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Caplan, M.; Bucher, K.; Tulupov, A.

    The goal of this project was to develop a prototype medical waste destruction facility based on the AC plasma torch capable of processing 150 kg of waste per hour while satisfying US EPA emission standards. The project was to provide the first opportunity for a joint U.S.-Russian project using an AC Plasma Torch in a hazardous waste destruction system to be assembled and operated in the U.S. thus promoting the commercialization in the U.S. of this joint U.S.-Russian developed technology. This project was a collaboration between the Russian Institute Soliton- NTT, the U.S industrial partner Scientific Utilization Inc. (SUI) andmore » Lawrence Livermore National Laboratory ( LLNL). The project was funded by DOE for a total of $1.2 million with $600K for allocated for Phase I and $600K for Phase II. The Russian team received about $800K over the two (2) year period while LLNL received $400K. SUI was to provide in kind matching funds totaling $1.2 million.« less

  16. Two Distinctive Phenotypes of AcMNPV Display Different Immune Abilities and Intracellular Destiny

    PubMed Central

    Molina, Guido N.; Tavarone, Eugenia; Taboga, Oscar; Molinari, Paula

    2016-01-01

    The budded phenotype (BV) of the baculovirus AcMNPV has been demonstrated to have strong immunostimulatory properties that are relevant for the development of vaccines and antiviral therapies. Although the occluded phenotype (ODV) shares the main structural proteins and its genome with BV, it has been poorly studied in mammals. In this study, we assessed the capacity of ODV to induce immune responses in mice. In contrast to BVs, ODVs failed to promote the secretion of IFN-gamma, IL-6 and Il-12 and to induce antiviral activity against VSV in the short term. Furthermore, ODVs were unable to induce cellular immunity against a coadministered antigen 7 days after inoculation. By analyzing the interaction of ODVs with BMDCs, we observed that although ODVs entered the cells reaching late and acidic endosomes, they did not induce their maturation. Finally, we also analyzed if BVs and ODVs followed different routes in the cell during the infection. BVs, but not ODVs, colocalized with the protein ovalbumin in compartments with the presence of proteases. The results suggest that structural differences could be responsible for their different destinies in the dendritic cell and this could lead to a different impact on the immune response. PMID:28033419

  17. The ACS statistical analyzer

    DOT National Transportation Integrated Search

    2010-03-01

    This document provides guidance for using the ACS Statistical Analyzer. It is an Excel-based template for users of estimates from the American Community Survey (ACS) to assess the precision of individual estimates and to compare pairs of estimates fo...

  18. Controlling Arc Length in Plasma Welding

    NASA Technical Reports Server (NTRS)

    Iceland, W. F.

    1986-01-01

    Circuit maintains arc length on irregularly shaped workpieces. Length of plasma arc continuously adjusted by control circuit to maintain commanded value. After pilot arc is established, contactor closed and transfers arc to workpiece. Control circuit then half-wave rectifies ac arc voltage to produce dc control signal proportional to arc length. Circuit added to plasma arc welding machines with few wiring changes. Welds made with circuit cleaner and require less rework than welds made without it. Beads smooth and free of inclusions.

  19. The AC photovoltaic module is here!

    NASA Astrophysics Data System (ADS)

    Strong, Steven J.; Wohlgemuth, John H.; Wills, Robert H.

    1997-02-01

    This paper describes the design, development, and performance results of a large-area photovoltaic module whose electrical output is ac power suitable for direct connection to the utility grid. The large-area ac PV module features a dedicated, integrally mounted, high-efficiency dc-to-ac power inverter with a nominal output of 250 watts (STC) at 120 Vac, 60 H, that is fully compatible with utility power. The module's output is connected directly to the building's conventional ac distribution system without need for any dc wiring, string combiners, dc ground-fault protection or additional power-conditioning equipment. With its advantages, the ac photovoltaic module promises to become a universal building block for use in all utility-interactive PV systems. This paper discusses AC Module design aspects and utility interface issues (including islanding).

  20. A new LTPS TFT AC pixel circuit for an AMOLED

    NASA Astrophysics Data System (ADS)

    Yongwen, Zhang; Wenbin, Chen

    2013-01-01

    This work presents a new voltage programmed pixel circuit for an active-matrix organic light-emitting diode (AMOLED) display. The proposed pixel circuit consists of six low temperature polycrystalline silicon thin-film transistors (LTPS TFTs), one storage capacitor, and one OLED, and is verified by simulation work using HSPICE software. Besides effectively compensating for the threshold voltage variation of the driving TFT and OLED, the proposed pixel circuit offers an AC driving mode for the OLED, which can suppress the degradation of the OLED. Moreover, a high contrast ratio can be achieved by the proposed pixel circuit since the OLED does not emit any light except for the emission period.

  1. A study of some features of ac and dc electric power systems for a space station

    NASA Technical Reports Server (NTRS)

    Hanania, J. I.

    1983-01-01

    This study analyzes certain selected topics in rival dc and high frequency ac electric power systems for a Space Station. The interaction between the Space Station and the plasma environment is analyzed, leading to a limit on the voltage for the solar array and a potential problem with resonance coupling at high frequencies. Certain problems are pointed out in the concept of a rotary transformer, and further development work is indicated in connection with dc circuit switching, special design of a transmission conductor for the ac system, and electric motors. The question of electric shock hazards, particularly at high frequency, is also explored. and a problem with reduced skin resistance and therefore increased hazard with high frequency ac is pointed out. The study concludes with a comparison of the main advantages and disadvantages of the two rival systems, and it is suggested that the choice between the two should be made after further studies and development work are completed.

  2. Filters for cathodic arc plasmas

    DOEpatents

    Anders, Andre; MacGill, Robert A.; Bilek, Marcela M. M.; Brown, Ian G.

    2002-01-01

    Cathodic arc plasmas are contaminated with macroparticles. A variety of magnetic plasma filters has been used with various success in removing the macroparticles from the plasma. An open-architecture, bent solenoid filter, with additional field coils at the filter entrance and exit, improves macroparticle filtering. In particular, a double-bent filter that is twisted out of plane forms a very compact and efficient filter. The coil turns further have a flat cross-section to promote macroparticle reflection out of the filter volume. An output conditioning system formed of an expander coil, a straightener coil, and a homogenizer, may be used with the magnetic filter for expanding the filtered plasma beam to cover a larger area of the target. A cathodic arc plasma deposition system using this filter can be used for the deposition of ultrathin amorphous hard carbon (a-C) films for the magnetic storage industry.

  3. Slow-onset and fast-onset symptom presentations in acute coronary syndrome (ACS): new perspectives on prehospital delay in patients with ACS.

    PubMed

    O'Donnell, Sharon; McKee, Gabrielle; Mooney, Mary; O'Brien, Frances; Moser, Debra K

    2014-04-01

    Patient decision delay is the main reason why many patients fail to receive timely medical intervention for symptoms of acute coronary syndrome (ACS). This study examines the validity of slow-onset and fast-onset ACS presentations and their influence on ACS prehospital delay times. A fast-onset ACS presentation is characterized by sudden, continuous, and severe chest pain, and slow-onset ACS pertains to all other ACS presentations. Baseline data pertaining to medical profiles, prehospital delay times, and ACS symptoms were recorded for all ACS patients who participated in a large multisite randomized control trial (RCT) in Dublin, Ireland. Patients were interviewed 2-4 days after their ACS event, and data were gathered using the ACS Response to Symptom Index. Only baseline data from the RCT, N = 893 patients, were analyzed. A total of 65% (n = 577) of patients experienced slow-onset ACS presentation, whereas 35% (n = 316) experienced fast-onset ACS. Patients who experienced slow-onset ACS were significantly more likely to have longer prehospital delays than patients with fast-onset ACS (3.5 h vs. 2.0 h, respectively, t = -5.63, df 890, p < 0.001). A multivariate analysis of delay revealed that, in the presence of other known delay factors, the only independent predictors of delay were slow-onset and fast-onset ACS (β = -.096, p < 0.002) and other factors associated with patient behavior. Slow-onset ACS and fast-onset ACS presentations are associated with distinct behavioral patterns that significantly influence prehospital time frames. As such, slow-onset ACS and fast-onset ACS are legitimate ACS presentation phenomena that should be seriously considered when examining the factors associated with prehospital delay. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Structure-Specific Effects of Short-Chain Fatty Acids on Plasma Cholesterol Concentration in Male Syrian Hamsters.

    PubMed

    Zhao, Yimin; Liu, Jianhui; Hao, Wangjun; Zhu, Hanyue; Liang, Ning; He, Zouyan; Ma, Ka Ying; Chen, Zhen-Yu

    2017-12-20

    Previous studies have shown that short-chain fatty acids (SCFAs) are capable of decreasing plasma cholesterol. However, the relative plasma-cholesterol-lowering activity of individual SCFAs and the underlying mechanisms by which SCFAs decrease plasma cholesterol remain largely unknown. The present study was done to compare the plasma-cholesterol-lowering potencies of four common SCFAs with 2-5 carbons and to investigate their interactions with gene expressions of key regulatory factors involved in cholesterol metabolism. For 6 weeks, five groups of male Golden hamsters were fed either a control high-cholesterol diet (HCD) or one of the four experimental HCDs containing 0.5 mol of acetate (Ac), propionate (Pr), butyrate (Bu), or valerate (Va) per kilogram of the diet. The results showed that Ac, Pr, and Bu significantly reduced plasma total cholesterol (TC) by 24, 18, and 17% (P < 0.05), respectively. All four SCFAs could decrease non-HDL cholesterol (non-HDL-C) and the non-HDL-C/HDL-C ratio. The addition of Ac, Pr, or Bu into the diet significantly promoted fecal excretion of bile acids by 121, 113, or 120% (P < 0.05), respectively, and upregulated the gene expressions of sterol-regulatory-element-binding protein 2 (SREBP2), low-density-lipoprotein receptor (LDLR), and cholesterol 7α-hydroxylase (CYP7A1) in the liver. It was concluded that SCFAs with 2-4 carbons (Ac, Pr, and Bu) are more hypocholesterolemic than Va, which has 5 carbons, via enhancing fecal excretion of bile acids and promoting the hepatic uptake of cholesterol from the blood.

  5. Transient AC voltage related phenomena for HVDC schemes connected to weak AC systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pilotto, L.A.S.; Szechtman, M.; Hammad, A.E.

    1992-07-01

    In this paper a didactic explanation of voltage stability associated phenomena at HVDC terminals is presented. Conditions leading to ac voltage collapse problems are identified. A mechanism that excites control-induced voltage oscillations is shown. The voltage stability factor is used for obtaining the maximum power limits of ac/dc systems operating with different control strategies. Correlation to Pd {times} Id curves is given. Solutions for eliminating the risks of voltage collapse and for avoiding control-induced oscillations are discussed. The results are supported by detailed digital simulations of a weak ac/dc system using EMTP.

  6. Electrodeless RF Plasma Thruster Using m = 0 Coil

    NASA Astrophysics Data System (ADS)

    Nishimura, Shuichi; Arai, Daisuke; Kuwahara, Daisuke; Shinohara, Shunjiro

    2016-10-01

    In order to realize a deep space exploration in the future, we have been developing a next generation electrodeless electric propulsion system by electromagnetic acceleration of high-density helicon plasma. A new proposed method by m = 0 coil plasma acceleration (m is an azimuthal mode number) is based on the Lorentz force: a product of the induced azimuthal current by supplying an AC current to the m = 0 coil and the radial component of the externally applied magnetic field (divergent field configuration). Here, we have investigated the dependences of an ion velocity and an electron density on the external parameters, leading to optimized conditions, using the SHD device. By increasing AC current on the order of 100 A, we could see the increase of ion velocity and electron density by a factor of 2.5 and 3, respectively.

  7. pH-Controlled Bacillus thuringiensis Cry1Ac Protoxin Loading and Release from Polyelectrolyte Microcapsules

    PubMed Central

    Yang, Wenhui; He, Kanglai; Zhang, Jie; Guo, Shuyuan

    2012-01-01

    Crystal proteins synthesized by Bacillus thuringiensis (Bt) have been used as biopesticides because of their toxicity to the insect larval hosts. To protect the proteins from environmental stress to extend their activity, we have developed a new microcapsule formulation. Poly (acrylic acid) (PAH) and poly (styrene sulfonate) (PSS) were fabricated through layer-by-layer self-assembly based on a CaCO3 core. Cry1Ac protoxins were loaded into microcapsules through layer-by-layer self-assembly at low pH, and the encapsulated product was stored in water at 4°C. Scanning electron microscopy (SEM) was used to observe the morphology of the capsules. To confirm the successful encapsulation, the loading results were observed with a confocal laser scattering microscope (CLSM), using fluorescein-labeled Cry1Ac protoxin (FITC-Cry1Ac). The protoxins were released from the capsule under the alkaline condition corresponding to the midgut of certain insects, a condition which seldom exists elsewhere in the environment. The following bioassay experiment demonstrated that the microcapsules with Cry1Ac protoxins displayed approximately equivalent insecticidal activity to the Asian corn borer compared with free Cry1Ac protoxins, and empty capsules proved to have no effect on insects. Further result also indicated that the formulation could keep stable under the condition of heat and desiccation. These results suggest that this formulation provides a promising methodology that protects protoxins from the environment and releases them specifically in the target insects’ midgut, which has shown potential as biopesticide in the field. PMID:23024810

  8. Microfabricated AC impedance sensor

    DOEpatents

    Krulevitch, Peter; Ackler, Harold D.; Becker, Frederick; Boser, Bernhard E.; Eldredge, Adam B.; Fuller, Christopher K.; Gascoyne, Peter R. C.; Hamilton, Julie K.; Swierkowski, Stefan P.; Wang, Xiao-Bo

    2002-01-01

    A microfabricated instrument for detecting and identifying cells and other particles based on alternating current (AC) impedance measurements. The microfabricated AC impedance sensor includes two critical elements: 1) a microfluidic chip, preferably of glass substrates, having at least one microchannel therein and with electrodes patterned on both substrates, and 2) electrical circuits that connect to the electrodes on the microfluidic chip and detect signals associated with particles traveling down the microchannels. These circuits enable multiple AC impedance measurements of individual particles at high throughput rates with sufficient resolution to identify different particle and cell types as appropriate for environmental detection and clinical diagnostic applications.

  9. The Contrasting Relationships between Betaine and Homocysteine in Two Clinical Cohorts are Associated with Plasma Lipids and Drug Treatments

    PubMed Central

    Lever, Michael; George, Peter M.; Atkinson, Wendy; Elmslie, Jane L.; Slow, Sandy; Molyneux, Sarah L.; Troughton, Richard W.; Richards, A. Mark; Frampton, Christopher M.; Chambers, Stephen T.

    2012-01-01

    Background Urinary betaine excretion positively correlated with plasma homocysteine in outpatients attending a lipid disorders clinic (lipid clinic study). We aimed to confirm this in subjects with established vascular disease. Methods The correlation between betaine excretion and homocysteine was compared in samples collected from subjects 4 months after hospitalization for an acute coronary episode (ACS study, 415 urine samples) and from 158 sequential patients visiting a lipid disorders clinic. Principal findings In contrast to the lipid clinic study, betaine excretion and plasma homocysteine did not correlate in the total ACS cohort. Differences between the patient groups included age, non-HDL cholesterol and medication. In ACS subjects with below median betaine excretion, excretion correlated (using log transformed data) negatively with plasma homocysteine (r = −0.17, p = 0.019, n = 199), with no correlation in the corresponding subset of the lipid clinic subjects. In ACS subjects with above median betaine excretion a positive trend (r = +0.10) between betaine excretion and homocysteine was not significant; the corresponding correlation in lipid clinic subjects was r = +0.42 (p = 0.0001). In ACS subjects, correlations were stronger when plasma non-HDL cholesterol and betaine excretion were above the median, r = +0.20 (p = 0.045); in subjects above median non-HDL cholesterol and below median betaine excretion, r = −0.26 (p = 0.012). ACS subjects taking diuretics or proton pump inhibitors had stronger correlations, negative with lower betaine excretion and positive with higher betaine excretion. Conclusions Betaine excretion correlates with homocysteine in subjects with elevated blood lipids. PMID:22396767

  10. Analysis of Drop Oscillations Excited by an Electrical Point Force in AC EWOD

    NASA Astrophysics Data System (ADS)

    Oh, Jung Min; Ko, Sung Hee; Kang, Kwan Hyoung

    2008-03-01

    Recently, a few researchers have reported the oscillation of a sessile drop in AC EWOD (electrowetting on dielectrics), and some of its consequences. The drop oscillation problem in AC EWOD is associated with various applications based on electrowetting such as LOC (lab-on-a-chip), liquid lens, and electronic display. However, no theoretical analysis of the problem has been attempted yet. In the present paper, we propose a theoretical model to analyze the oscillation by applying the conventional method to analyze the drop oscillation. The domain perturbation method is used to derive the shape mode equations under the assumptions of weak viscous flow and small deformation. The Maxwell stress is exerted on the three-phase contact line of the droplet like a point force. The force is regarded as a delta function, and is decomposed into the driving forces of each shape mode. The theoretical results on the shape and the frequency responses are compared with experiments, which shows a qualitative agreement.

  11. Atmospheric plasma generation for LCD panel cleaning

    NASA Astrophysics Data System (ADS)

    Kim, Gyu-Sik; Won, Chung-Yuen; Choi, Ju-Yeop; Yim, C. H.

    2007-12-01

    UV lamp systems have been used for cleaning of display panels of TFT LCD or Plasma Display Panel (PDP). However, the needs for high efficient cleaning and low cost made high voltage plasma cleaning techniques to be developed and to be improved. Dielectric-barrier discharges (DBDs), also referred to as barrier discharges or silent discharges have for a long time been exclusively related to ozone generation. In this paper, a 6kW high voltage plasma power supply system was developed for LCD cleaning. The -phase input voltage is rectified and then inverter system is used to make a high frequency pulse train, which is rectified after passing through a high-power transformer. Finally, bi-directional high voltage pulse switching circuits are used to generate the high voltage plasma. Some experimental results showed the usefulness of atmospheric plasma for LCD panel cleaning.

  12. Plasma acylcarnitines during insulin stimulation in humans are reflective of age-related metabolic dysfunction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Consitt, Leslie A., E-mail: consitt@ohio.edu; Diabetes Institute, Ohio University, Athens, OH, 45701; Ohio Musculoskeletal and Neurological Institute, Ohio University, Athens, OH, 45701

    The purpose of this study was to determine if plasma acylcarnitine (AC) profiling is altered under hyperinsulinemic conditions as part of the aging process. Fifteen young, lean (19–29 years) and fifteen middle-to older-aged (57–82 years) individuals underwent a 2-hr euglycemic-hyperinsulinemic clamp. Plasma samples were obtained at baseline, 20 min, 50 min, and 120 min for analysis of AC species and amino acids. Skeletal muscle biopsies were performed after 60 min of insulin-stimulation for analysis of acetyl-CoA carboxylase (ACC) phosphorylation. Insulin infusion decreased the majority of plasma short-, medium-, and long-chain (SC, MC, and LC, respectively) AC. However, during the initial 50 min, a number ofmore » MC and LC AC species (C10, C10:1, C12:1, C14, C16, C16:1, C18) remained elevated in aged individuals compared to their younger counterparts indicating a lag in responsiveness. Additionally, the insulin-induced decline in skeletal muscle ACC phosphorylation was blunted in the aged compared to young individuals (−24% vs. −56%, P < 0.05). These data suggest that a desensitization to insulin during aging, possibly at the level of skeletal muscle ACC phosphorylation, results in a diminished ability to transition to glucose oxidation indicative of metabolic inflexibility. - Highlights: • Plasma acylcarnitine profiling reveals metabolic inflexibility in aged individuals. • Time course acylcarnitine profiling is critical to identify metabolic dysfunction. • Acetyl-CoA carboxylase phosphorylation status is related to metabolic dysfunction.« less

  13. High voltage AC/AC electrochemical capacitor operating at low temperature in salt aqueous electrolyte

    NASA Astrophysics Data System (ADS)

    Abbas, Qamar; Béguin, François

    2016-06-01

    We demonstrate that an activated carbon (AC)-based electrochemical capacitor implementing aqueous lithium sulfate electrolyte in 7:3 vol:vol water/methanol mixture can operate down to -40 °C with good electrochemical performance. Three-electrode cell investigations show that the faradaic contributions related with hydrogen chemisorption in the negative AC electrode are thermodynamically unfavored at -40 °C, enabling the system to work as a typical electrical double-layer (EDL) capacitor. After prolonged floating of the AC/AC capacitor at 1.6 V and -40°C, the capacitance, equivalent series resistance and efficiency remain constant, demonstrating the absence of ageing related with side redox reactions at this temperature. Interestingly, when temperature is increased back to 24 °C, the redox behavior due to hydrogen storage reappears and the system behaves as a freshly prepared one.

  14. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and remove...

  15. Plasma acylcarnitines during insulin stimulation in humans are reflective of age-related metabolic dysfunction.

    PubMed

    Consitt, Leslie A; Koves, Timothy R; Muoio, Deborah M; Nakazawa, Masato; Newton, Christopher A; Houmard, Joseph A

    2016-10-28

    The purpose of this study was to determine if plasma acylcarnitine (AC) profiling is altered under hyperinsulinemic conditions as part of the aging process. Fifteen young, lean (19-29 years) and fifteen middle-to older-aged (57-82 years) individuals underwent a 2-hr euglycemic-hyperinsulinemic clamp. Plasma samples were obtained at baseline, 20 min, 50 min, and 120 min for analysis of AC species and amino acids. Skeletal muscle biopsies were performed after 60 min of insulin-stimulation for analysis of acetyl-CoA carboxylase (ACC) phosphorylation. Insulin infusion decreased the majority of plasma short-, medium-, and long-chain (SC, MC, and LC, respectively) AC. However, during the initial 50 min, a number of MC and LC AC species (C10, C10:1, C12:1, C14, C16, C16:1, C18) remained elevated in aged individuals compared to their younger counterparts indicating a lag in responsiveness. Additionally, the insulin-induced decline in skeletal muscle ACC phosphorylation was blunted in the aged compared to young individuals (-24% vs. -56%, P < 0.05). These data suggest that a desensitization to insulin during aging, possibly at the level of skeletal muscle ACC phosphorylation, results in a diminished ability to transition to glucose oxidation indicative of metabolic inflexibility. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Plasma acylcarnitines during insulin stimulation in humans are reflective of age-related metabolic dysfunction

    PubMed Central

    Consitt, Leslie A.; Koves, Timothy R.; Muoio, Deborah M.; Nakazawa, Masato; Newton, Christopher A.; Houmard, Joseph A.

    2016-01-01

    The purpose of this study was to determine if plasma acylcarnitine (AC) profiling is altered under hyperinsulinemic conditions as part of the aging process. Fifteen young, lean (19–29 years) and fifteen middle- to older-aged (57–82 years) individuals underwent a 2-hr euglycemic-hyperinsulinemic clamp. Plasma samples were obtained at baseline, 20 min, 50 min, and 120 min for analysis of AC species and amino acids. Skeletal muscle biopsies were performed after 60 min of insulin-stimulation for analysis of acetyl-CoA carboxylase (ACC) phosphorylation. Insulin infusion decreased the majority of plasma short-, medium-, and long-chain (SC, MC, and LC, respectively) AC. However, during the initial 50 min, a number of MC and LC AC species (C10, C10:1, C12:1, C14, C16, C16:1, C18) remained elevated in aged individuals compared to their younger counterparts indicating a lag in responsiveness. Additionally, the insulin-induced decline in skeletal muscle ACC phosphorylation was blunted in the aged compared to young individuals (−24% vs. −56%, P<0.05). These data suggest that a desensitization to insulin during aging, possibly at the level of skeletal muscle ACC phosphorylation, results in a diminished ability to transition to glucose oxidation indicative of metabolic inflexibility. PMID:27693789

  17. Comparison of Omadacycline and Tigecycline Pharmacokinetics in the Plasma, Epithelial Lining Fluid, and Alveolar Cells of Healthy Adult Subjects.

    PubMed

    Gotfried, Mark H; Horn, Karolyn; Garrity-Ryan, Lynne; Villano, Stephen; Tzanis, Evan; Chitra, Surya; Manley, Amy; Tanaka, S Ken; Rodvold, Keith A

    2017-09-01

    The steady-state concentrations of omadacycline and tigecycline in the plasma, epithelial lining fluid (ELF), and alveolar cells (AC) of 58 healthy adult subjects were obtained. Subjects were administered either omadacycline at 100 mg intravenously (i.v.) every 12 h for two doses followed by 100 mg i.v. every 24 h for three doses or tigecycline at an initial dose of 100 mg i.v. followed by 50 mg i.v. every 12 h for six doses. A bronchoscopy and bronchoalveolar lavage were performed once in each subject following the start of the fifth dose of omadacycline at 0.5, 1, 2, 4, 8, 12, or 24 h and after the start of the seventh dose of tigecycline at 2, 4, 6, or 12 h. The value of the area under the concentration-time curve (AUC) from time zero to 24 h postdosing (AUC 0-24 ) (based on mean concentrations) in ELF and the ratio of the ELF to total plasma omadacycline concentration based on AUC 0-24 values were 17.23 mg · h/liter and 1.47, respectively. The AUC 0-24 value in AC was 302.46 mg · h/liter, and the ratio of the AC to total plasma omadacycline concentration was 25.8. In comparison, the values of the AUC from time zero to 12 h postdosing (AUC 0-12 ) based on the mean concentrations of tigecycline in ELF and AC were 3.16 and 38.50 mg · h/liter, respectively. The ratio of the ELF and AC to total plasma concentrations of tigecycline based on AUC 0-12 values were 1.71 and 20.8, respectively. The pharmacokinetic advantages of higher and sustained concentrations of omadacycline compared to those of tigecycline in plasma, ELF, and AC suggest that omadacycline is a promising antibacterial agent for the treatment of lower respiratory tract bacterial infections caused by susceptible pathogens. Copyright © 2017 Gotfried et al.

  18. A Novel Angiotensin I-Converting Enzyme Mutation (S333W) Impairs N-Domain Enzymatic Cleavage of the Anti-Fibrotic Peptide, AcSDKP

    PubMed Central

    Danilov, Sergei M.; Wade, Michael S.; Schwager, Sylva L.; Douglas, Ross G.; Nesterovitch, Andrew B.; Popova, Isolda A.; Hogarth, Kyle D.; Bhardwaj, Nakul; Schwartz, David E.; Sturrock, Edward D.; Garcia, Joe G. N.

    2014-01-01

    Background Angiotensin I-converting enzyme (ACE) has two functional N- and C-domain active centers that display differences in the metabolism of biologically-active peptides including the hemoregulatory tetrapeptide, Ac-SDKP, hydrolysed preferentially by the N domain active center. Elevated Ac-SDKP concentrations are associated with reduced tissue fibrosis. Results We identified a patient of African descent exhibiting unusual blood ACE kinetics with reduced relative hydrolysis of two synthetic ACE substrates (ZPHL/HHL ratio) suggestive of the ACE N domain center inactivation. Inhibition of blood ACE activity by anti-catalytic mAbs and ACE inhibitors and conformational fingerprint of blood ACE suggested overall conformational changes in the ACE molecule and sequencing identified Ser333Trp substitution in the N domain of ACE. In silico analysis demonstrated S333W localized in the S1 pocket of the active site of the N domain with the bulky Trp adversely affecting binding of ACE substrates due to steric hindrance. Expression of mutant ACE (S333W) in CHO cells confirmed altered kinetic properties of mutant ACE and conformational changes in the N domain. Further, the S333W mutant displayed decreased ability (5-fold) to cleave the physiological substrate AcSDKP compared to wild-type ACE. Conclusions and Significance A novel Ser333Trp ACE mutation results in dramatic changes in ACE kinetic properties and lowered clearance of Ac-SDKP. Individuals with this mutation (likely with significantly increased levels of the hemoregulatory tetrapeptide in blood and tissues), may confer protection against fibrosis. PMID:24505347

  19. Effects of atmospheric nonthermal plasma on invasion of colorectal cancer cells

    NASA Astrophysics Data System (ADS)

    Kim, Chul-Ho; Kwon, Seyeoul; Bahn, Jae Hoon; Lee, Keunho; Jun, Seung Ik; Rack, Philip D.; Baek, Seung Joon

    2010-06-01

    The effect that the gas content and plasma power of atmospheric, nonthermal plasma has on the invasion activity in colorectal cancer cells has been studied. Helium and helium plus oxygen plasmas were induced through a nozzle and operated with an ac power of less than 10 kV which exhibited a length of 2.5 cm and a diameter of 3-4 mm in ambient air. Treatment of cancer cells with the plasma jet resulted in a decrease in cell migration/invasion with higher plasma intensity and the addition of oxygen to the He flow gas.

  20. The KAC family of kinesin-like proteins is essential for the association of chloroplasts with the plasma membrane in land plants.

    PubMed

    Suetsugu, Noriyuki; Sato, Yoshikatsu; Tsuboi, Hidenori; Kasahara, Masahiro; Imaizumi, Takato; Kagawa, Takatoshi; Hiwatashi, Yuji; Hasebe, Mitsuyasu; Wada, Masamitsu

    2012-11-01

    Chloroplasts require association with the plasma membrane for movement in response to light and for appropriate positioning within the cell to capture photosynthetic light efficiently. In Arabidopsis, CHLOROPLAST UNUSUAL POSITIONING 1 (CHUP1), KINESIN-LIKE PROTEIN FOR ACTIN-BASED CHLOROPLAST MOVEMENT 1 (KAC1) and KAC2 are required for both the proper movement of chloroplasts and the association of chloroplasts with the plasma membrane, through the reorganization of short actin filaments located on the periphery of the chloroplasts. Here, we show that KAC and CHUP1 orthologs (AcKAC1, AcCHUP1A and AcCHUP1B, and PpKAC1 and PpKAC2) play important roles in chloroplast positioning in the fern Adiantum capillus-veneris and the moss Physcomitrella patens. The knockdown of AcKAC1 and two AcCHUP1 genes induced the aggregation of chloroplasts around the nucleus. Analyses of A. capillus-veneris mutants containing perinuclear-aggregated chloroplasts confirmed that AcKAC1 is required for chloroplast-plasma membrane association. In addition, P. patens lines in which two KAC genes had been knocked out showed an aggregated chloroplast phenotype similar to that of the fern kac1 mutants. These results indicate that chloroplast positioning and movement are mediated through the activities of KAC and CHUP1 proteins, which are conserved in land plants.

  1. Spectral and Power Stability Tests of Deep UV LEDs for AC Charge Management

    NASA Astrophysics Data System (ADS)

    Sun, Ke-Xun; Higuchi, Sei; Goh, Allex; Allard, Brett; Gill, Dale; Buchman, Saps; Byer, Robert

    2006-11-01

    Deep ultraviolet (UV) LEDs have recently been used in AC charge management experiments to support gravitational reference sensors for future space missions. The UV LED based charge management system offers compact size, light weight, and low power consumption compared to plasma sources. The AC charge management technique, which is enabled by easy modulation of UV LED output, achieves higher dynamic range for charge control. Further, the high modulation frequency, which is out of the gravitational wave detection band, reduces disturbances to the proof mass. However, there is a need to test and possibly improve the lifetime of UV LEDs, which were developed only a year ago. We have initiated a series of spectral and power stability tests for UV LEDs and designed experiments according to the requirements of AC charge management. We operate UV LEDs with a modulated current drive and maintain the operating temperature at 22 °C,28 similar to the LISA spacecraft working condition. The testing procedures involve measuring the baseline spectral shape and output power level prior to the beginning of the tests and then re-measuring the same quantities periodically. As of the date of submission (August 28th, 2006), we have operated a UV LED for more than 2,700 hours.

  2. The AC 2000.2 Catalogue

    NASA Astrophysics Data System (ADS)

    Urban, S. E.; Corbin, T. E.; Wycoff, G. L.; Makarov, V. V.; Høg, E.; Fabricius, C.

    2001-12-01

    For over 100 years, the international project known as the Astrographic Catalogue -- which involved 20 observatories tasked to photograph the sky -- has held an unfulfilled promised of yielding a wealth of astrometric information. This promise was not realized due to the inadequate reductions of the project's plates. However, in 1997 the U.S. Naval Observatory (USNO) completed the reductions of the 22,660 plates. That catalogue, named the AC 2000, contained positions and magnitudes for 4.6 million stars down to about v magnitude 12.5. Due to the early epochs of the data -- averaging 1907 -- and the positional accuracies -- between 150 and 400 milliarcseconds -- the data are extremely valuable in computing proper motions. In 1997, these positions were used to form the proper motions of the ACT Reference Catalogue. In 1999, USNO and Copenhagen University Observatory (CUO) partnered to create the Tycho-2 Catalogue. The CUO group re-analyzed the data from the Tycho experiment on the Hipparcos satellite. The USNO group re-analyzed over 140 positional catalogs which were combined with the expanded Tycho positions from the CUO group to compute the Tycho-2 proper motions. The largest contributor to these proper motions was the re-analyzed Astrographic Catalogue; the latest version being known as the AC 2000.2 Catalogue. There are two major differences between the AC 2000 and the AC 2000.2. First, the reference catalog used in AC 2000.2 was an expanded version of the Astrographic Catalogue Reference Stars that was rigorously derived on the Hipparcos Celestial Reference Frame. The second is that AC 2000.2 contains photometry from Tycho-2, where available. A description of the AC 2000.2 Catalogue, the reduction techniques used, how it compares with the 1997 version, and information on obtaining the data will be presented.

  3. Temperature-accelerated molecular dynamics gives insights into globular conformations sampled in the free state of the AC catalytic domain.

    PubMed

    Selwa, Edithe; Huynh, Tru; Ciccotti, Giovanni; Maragliano, Luca; Malliavin, Thérèse E

    2014-10-01

    The catalytic domain of the adenyl cyclase (AC) toxin from Bordetella pertussis is activated by interaction with calmodulin (CaM), resulting in cAMP overproduction in the infected cell. In the X-ray crystallographic structure of the complex between AC and the C terminal lobe of CaM, the toxin displays a markedly elongated shape. As for the structure of the isolated protein, experimental results support the hypothesis that more globular conformations are sampled, but information at atomic resolution is still lacking. Here, we use temperature-accelerated molecular dynamics (TAMD) simulations to generate putative all-atom models of globular conformations sampled by CaM-free AC. As collective variables, we use centers of mass coordinates of groups of residues selected from the analysis of standard molecular dynamics (MD) simulations. Results show that TAMD allows extended conformational sampling and generates AC conformations that are more globular than in the complexed state. These structures are then refined via energy minimization and further unrestrained MD simulations to optimize inter-domain packing interactions, thus resulting in the identification of a set of hydrogen bonds present in the globular conformations. © 2014 Wiley Periodicals, Inc.

  4. Numerical Simulations of Plasma Based Flow Control Applications

    NASA Technical Reports Server (NTRS)

    Suzen, Y. B.; Huang, P. G.; Jacob, J. D.; Ashpis, D. E.

    2005-01-01

    A mathematical model was developed to simulate flow control applications using plasma actuators. The effects of the plasma actuators on the external flow are incorporated into Navier Stokes computations as a body force vector. In order to compute this body force vector, the model solves two additional equations: one for the electric field due to the applied AC voltage at the electrodes and the other for the charge density representing the ionized air. The model is calibrated against an experiment having plasma-driven flow in a quiescent environment and is then applied to simulate a low pressure turbine flow with large flow separation. The effects of the plasma actuator on control of flow separation are demonstrated numerically.

  5. Initial NIST AC QHR Measurements

    PubMed Central

    Cage, M. E.; Shields, S. H.; Jeffery, A.

    2004-01-01

    We demonstrate that dc quantized Hall resistance (dc QHR) guideline properties and dc and ac QHR values can be measured without changing sample probe lead connections at the QHR device, and report ac QHR values that converge to the dc QHR value when using four-terminal-pair ac QHR measurements. This was accomplished during one cooldown using single-series and quadruple-series connections outside the sample probe. The QHR was measured from 0 Hz to 5500 Hz in 1:1 ratio at 20 µA to ±1 part in 107 uncertainties with a poor-quality QHR device. A good device would allow an order of magnitude smaller uncertainties over this frequency range. We exchanged positions of the QHR device and reference resistor in the bridge and remeasured the resistance ratios to remove dominant ac bridge effects. PMID:27366620

  6. Simultaneous distribution of AC and DC power

    DOEpatents

    Polese, Luigi Gentile

    2015-09-15

    A system and method for the transport and distribution of both AC (alternating current) power and DC (direct current) power over wiring infrastructure normally used for distributing AC power only, for example, residential and/or commercial buildings' electrical wires is disclosed and taught. The system and method permits the combining of AC and DC power sources and the simultaneous distribution of the resulting power over the same wiring. At the utilization site a complementary device permits the separation of the DC power from the AC power and their reconstruction, for use in conventional AC-only and DC-only devices.

  7. Oblique propagating electromagnetic ion - Cyclotron instability with A.C. field in outer magnetosphere

    NASA Astrophysics Data System (ADS)

    Pandey, R. S.; Singh, Vikrant; Rani, Anju; Varughese, George; Singh, K. M.

    2018-05-01

    In the present paper Oblique propagating electromagnetic ion-cyclotron wave has been analyzed for anisotropic multi ion plasma (H+, He+, O+ ions) in earth magnetosphere for the Dione shell of L=7 i.e., the outer radiation belt of the magnetosphere for Loss-cone distribution function with a spectral index j in the presence of A.C. electric field. Detail for particle trajectories and dispersion relation has been derived by using the method of characteristic solution on the basis of wave particle interaction and transformation of energy. Results for the growth rate have been calculated numerically for various parameters and have been compared for different ions present in magnetosphere. It has been found that for studying the wave over wider spectrum, anisotropy for different values of j should be taken. The effect of frequency of A.C. electric field and angle which propagation vector make with magnetic field, on growth rate has been explained.

  8. The AB Doradus system revisited: The dynamical mass of AB Dor A/C

    NASA Astrophysics Data System (ADS)

    Azulay, R.; Guirado, J. C.; Marcaide, J. M.; Martí-Vidal, I.; Ros, E.; Tognelli, E.; Jauncey, D. L.; Lestrade, J.-F.; Reynolds, J. E.

    2017-10-01

    Context. The study of pre-main-sequence (PMS) stars with model-independent measurements of their masses is essential to check the validity of theoretical models of stellar evolution. The well-known PMS binary AB Dor A/C is an important benchmark for this task, since it displays intense and compact radio emission, which makes possible the application of high-precision astrometric techniques to this system. Aims: We aim to revisit the dynamical masses of the components of AB Dor A/C to refine earlier comparisons between the measurements of stellar parameters and the predictions of stellar models. Methods: We observed in phase-reference mode the binary AB Dor A/C, 0.2'' separation, with the Australian Long Baseline Array at 8.4 GHz. The astrometric information resulting from our observations was analyzed along with previously reported VLBI, optical (Hipparcos), and infrared measurements. Results: The main star AB Dor A is clearly detected in all the VLBI observations, which allowed us to analyze the orbital motion of the system and to obtain model-independent dynamical masses of 0.90 ± 0.08 M⊙ and 0.090 ± 0.008 M⊙, for AB Dor A and AB Dor C, respectively. Comparisons with PMS stellar evolution models favor and age of 40-50 Myr for AB Dor A and of 25-120 Myr for AB Dor C. Conclusions: We show that the orbital motion of the AB Dor A/C system is remarkably well determined, leading to precise estimates of the dynamical masses. Comparison of our results with the prediction of evolutionary models support the observational evidence that theoretical models tend to slightly underestimate the mass of the low-mass stars.

  9. Dynamics of Ion Beam Charge Neutralization by Ferroelectric Plasma Sources

    NASA Astrophysics Data System (ADS)

    Stepanov, Anton D.; Gilson, Erik P.; Grisham, Larry R.; Kaganovich, Igor D.; Davidson, Ronald C.; Ji, Qing; Persaud, Arun; Seidl, Peter A.; Schenkel, Thomas

    2016-10-01

    Ferroelectric Plasma Sources (FEPSs) can generate plasma that provides effective space-charge neutralization of intense high-perveance ion beams. Here we present experimental results on charge neutralization of a high-perveance 38 keV Ar+ beam by a FEPS plasma. By comparing the measured beam radius with the envelope model for space-charge expansion, it is shown that a charge neutralization fraction of 98% is attainable. The transverse electrostatic potential of the ion beam is reduced from 15 V before neutralization to 0.3 V, implying that the energy of the neutralizing electrons is below 0.3 eV. Near-complete charge neutralization is established 5 μs after the driving pulse is applied to the FEPS, and can last for 35 μs. It is argued that the duration of neutralization is much longer than a reasonable lifetime of the plasma produced in the sub- μs surface discharge. Measurements of current flow in the driving circuit of the FEPS suggest that plasma can be generated for tens of μs after the high voltage pulse is applied. This is confirmed by fast photography of the plasma in the 1-meter long FEPS on NDCX-II, where effective charge neutralization of the beam was achieved with the optimized FEPS timing. This work was supported by the Office of Science of the US Department of Energy under contracts DE-AC0209CH11466 (PPPL) and DE-AC0205CH11231 (LBNL).

  10. Pulsed Plasma Thrusters for Small Spacecraft Attitude Control

    NASA Technical Reports Server (NTRS)

    McGuire, Melissa L.; Myers, Roger M.

    1996-01-01

    Pulsed plasma thrusters (PPT's) are a new option for attitude control of a small spacecraft and may result in reduced attitude control system (ACS) mass and cost. The primary purpose of an ACS is to orient the spacecraft configuration to the desired accuracy in inertial space. The ACS functions for which the PPT system will be analyzed include disturbance torque compensation and slewing maneuvers such as sun acquisition for which the small impulse bit and high specific impulse of the PPT offers unique advantages. The NASA Lewis Reserach Center (LeRC) currently has a contracted flight PPT system development program in place with Olin Aerospace and a delivery date of October 1997. The PPT system in this study are based upon the work being done under the NASA LeRC program. Analysis of the use of PPT's for ACS showed that the replacement of the standard momentum wheels and torque rods systems with a PTT system to perform the altitude control maneuvers on a small low Earth orbiting spacecraft reduced the ACS mass by 50 to 75 percent with no increase in required power level over comparable wheel-based systems.

  11. Pulsed plasma thrusters for small spacecraft attitude control

    NASA Technical Reports Server (NTRS)

    McGuire, Melissa L.; Myers, Roger M.

    1996-01-01

    Pulsed Plasma Thrusters (PPTS) are a new option for attitude control of a small spacecraft and may result in reduced attitude control system (ACS) mass and cost. The primary purpose of an ACS is to orient the spacecraft to the desired accuracy in inertial space. The ACS functions for which the PPT system will be analyzed include disturbance torque compensation, and slewing maneuvers such as sun acquisition for which the small impulse bit and high specific impulse of the PPT offers unique advantages. The NASA Lewis Research Center (LERC) currently has a contracted flight PPT system development program in place with Olin Aerospace with a delivery date of October 1997. The PPT systems in this study are based upon the work being done under the NASA LERC program. Analysis of the use of PPTs for ACS showed that the replacement of the standard momentum wheels and torque rods with a PPT system to perform the attitude control maneuvers on a small low Earth orbiting spacecraft reduced the ACS mass by 50 to 75% with no increase in required power level over comparable wheel-based systems, though rapid slewing power requirements may present an issue.

  12. New Composites LnBDC@AC and CB[6]@AC: From Design toward Selective Adsorption of Methylene Blue or Methyl Orange

    PubMed Central

    Santos, Guilherme de C.; Barros, Amanda L.; de Oliveira, Carlos A. F.; da Luz, Leonis L.; da Silva, Fausthon F.; Demets, Grégoire J.-F.; Alves Júnior, Severino

    2017-01-01

    New porous composites LnBDC@AC (AC = Activated carbon, Ln = Eu and Gd and BDC = 1,4-benzenedicaboxylate) and CB[6]@AC (CB[6] = Cucurbit[6]uril) were obtained using hydrothermal route. The LnBDC and CB[B] are located inside the pore of the carbon materials as was observed in SEM-EDS, XRPD and FT-IR analysis. Porosimetry analysis showed values typically between AC and LnBDC material, with pore size and surface area, respectively, 29,56 Å and 353.98 m2g-1 for LnBDC@AC and 35,53 Å and 353.98 m2g-1 for CB[6]@AC. Both materials showed good absorptive capacity of metil orange (MO) and methylene blue (MB) with selectivity as a function of pH. For acid pH, both materials present selectivity by MB and alkaline pH for MO, with notable performance for CB[6]@AC. Additionally, europium luminescence was used as structural probe to investigate the coordination environment of Eu3+ ions in the EuBDC@AC composite after adsorption experiment. PMID:28107440

  13. 21 CFR 886.1850 - AC-powered slitlamp biomicroscope.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false AC-powered slitlamp biomicroscope. 886.1850... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1850 AC-powered slitlamp biomicroscope. (a) Identification. An AC-powered slitlamp biomicroscope is an AC-powered device that is a...

  14. Experimental investigations on characteristics of boundary layer and control of transition on an airfoil by AC-DBD

    NASA Astrophysics Data System (ADS)

    Geng, Xi; Shi, Zhiwei; Cheng, Keming; Dong, Hao; Zhao, Qun; Chen, Sinuo

    2018-03-01

    Plasma-based flow control is one of the most promising techniques for aerodynamic problems, such as delaying the boundary layer transition. The boundary layer’s characteristics induced by AC-DBD plasma actuators and applied by the actuators to delay the boundary layer transition on airfoil at Ma = 0.3 were experimentally investigated. The PIV measurement was used to study the boundary layer’s characteristics induced by the plasma actuators. The measurement plane, which was parallel to the surface of the actuators and 1 mm above the surface, was involved in the test, including the perpendicular plane. The instantaneous results showed that the induced flow field consisted of many small size unsteady vortices which were eliminated by the time average. The subsequent oil-film interferometry skin friction measurement was conducted on a NASA SC(2)-0712 airfoil at Ma = 0.3. The coefficient of skin friction demonstrates that the plasma actuators successfully delay the boundary layer transition and the efficiency is better at higher driven voltage.

  15. High-performance modeling of plasma-based acceleration and laser-plasma interactions

    NASA Astrophysics Data System (ADS)

    Vay, Jean-Luc; Blaclard, Guillaume; Godfrey, Brendan; Kirchen, Manuel; Lee, Patrick; Lehe, Remi; Lobet, Mathieu; Vincenti, Henri

    2016-10-01

    Large-scale numerical simulations are essential to the design of plasma-based accelerators and laser-plasma interations for ultra-high intensity (UHI) physics. The electromagnetic Particle-In-Cell (PIC) approach is the method of choice for self-consistent simulations, as it is based on first principles, and captures all kinetic effects, and also scale favorably to many cores on supercomputers. The standard PIC algorithm relies on second-order finite-difference discretization of the Maxwell and Newton-Lorentz equations. We present here novel formulations, based on very high-order pseudo-spectral Maxwell solvers, which enable near-total elimination of the numerical Cherenkov instability and increased accuracy over the standard PIC method for standard laboratory frame and Lorentz boosted frame simulations. We also present the latest implementations in the PIC modules Warp-PICSAR and FBPIC on the Intel Xeon Phi and GPU architectures. Examples of applications will be given on the simulation of laser-plasma accelerators and high-harmonic generation with plasma mirrors. Work supported by US-DOE Contracts DE-AC02-05CH11231 and by the European Commission through the Marie Slowdoska-Curie fellowship PICSSAR Grant Number 624543. Used resources of NERSC.

  16. High-Frequency ac Power-Distribution System

    NASA Technical Reports Server (NTRS)

    Hansen, Irving G.; Mildice, James

    1987-01-01

    Loads managed automatically under cycle-by-cycle control. 440-V rms, 20-kHz ac power system developed. System flexible, versatile, and "transparent" to user equipment, while maintaining high efficiency and low weight. Electrical source, from dc to 2,200-Hz ac converted to 440-V rms, 20-kHz, single-phase ac. Power distributed through low-inductance cables. Output power either dc or variable ac. Energy transferred per cycle reduced by factor of 50. Number of parts reduced by factor of about 5 and power loss reduced by two-thirds. Factors result in increased reliability and reduced costs. Used in any power-distribution system requiring high efficiency, high reliability, low weight, and flexibility to handle variety of sources and loads.

  17. 78 FR 39345 - ACS Wireless, Inc.; Notice of Application

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-01

    ... on July 31, 1995 under the name MACTEL INC. Alaska Communications Systems Group, Inc. (``ACS Group...-owned subsidiary of ACS Group, held through ACS Group's wholly-owned subsidiary Alaska Communications... presently an investment company as defined in section 3(a) of the Act. 2. On June 4, 2012, ACS Group, ACS...

  18. Efficient Coupling of Fluid-Plasma and Monte-Carlo-Neutrals Models for Edge Plasma Transport

    NASA Astrophysics Data System (ADS)

    Dimits, A. M.; Cohen, B. I.; Friedman, A.; Joseph, I.; Lodestro, L. L.; Rensink, M. E.; Rognlien, T. D.; Sjogreen, B.; Stotler, D. P.; Umansky, M. V.

    2017-10-01

    UEDGE has been valuable for modeling transport in the tokamak edge and scrape-off layer due in part to its efficient fully implicit solution of coupled fluid neutrals and plasma models. We are developing an implicit coupling of the kinetic Monte-Carlo (MC) code DEGAS-2, as the neutrals model component, to the UEDGE plasma component, based on an extension of the Jacobian-free Newton-Krylov (JFNK) method to MC residuals. The coupling components build on the methods and coding already present in UEDGE. For the linear Krylov iterations, a procedure has been developed to ``extract'' a good preconditioner from that of UEDGE. This preconditioner may also be used to greatly accelerate the convergence rate of a relaxed fixed-point iteration, which may provide a useful ``intermediate'' algorithm. The JFNK method also requires calculation of Jacobian-vector products, for which any finite-difference procedure is inaccurate when a MC component is present. A semi-analytical procedure that retains the standard MC accuracy and fully kinetic neutrals physics is therefore being developed. Prepared for US DOE by LLNL under Contract DE-AC52-07NA27344 and LDRD project 15-ERD-059, by PPPL under Contract DE-AC02-09CH11466, and supported in part by the U.S. DOE, OFES.

  19. Plasma photonics in ICF & HED conditions

    NASA Astrophysics Data System (ADS)

    Michel, Pierre; Turnbull, David; Divol, Laurent; Pollock, Bradley; Chen, Cecilia Y.; Tubman, Eleanor; Goyon, Clement S.; Moody, John D.

    2015-11-01

    Interactions between multiple high-energy laser beams and plasma can be used to imprint refractive micro-structures in plasmas via the lasers' ponderomotive force. For example, Inertial confinement fusion (ICF) experiments at the National Ignition Facility already rely on the use of plasma gratings to redirect laser light inside an ICF target and tune the symmetry of the imploded core. More recently, we proposed new concepts of plasma polarizer and waveplate, based on two-wave mixing schemes and laser-induced plasma birefringence. In this talk, we will present new experimental results showing the first demonstration of a fully tunable plasma waveplate, which achieved near-perfect circular laser polarization. We will discuss further prospects for novel ``plasma photonics'' concepts based on two- and four-wave mixing, such as optical switches, bandpass filters, anti-reflection blockers etc. These might find applications in ICF and HED experiments by allowing to manipulate the lasers directly in-situ (i.e. inside the targets), as well as for the design of high power laser systems. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  20. AC conductivity and dielectric behavior of bulk Furfurylidenemalononitrile

    NASA Astrophysics Data System (ADS)

    El-Nahass, M. M.; Ali, H. A. M.

    2012-06-01

    AC conductivity and dielectric behavior for bulk Furfurylidenemalononitrile have been studied over a temperature range (293-333 K) and frequency range (50-5×106 Hz). The frequency dependence of ac conductivity, σac, has been investigated by the universal power law, σac(ω)=Aωs. The variation of the frequency exponent (s) with temperature was analyzed in terms of different conduction mechanisms, and it was found that the correlated barrier hopping (CBH) model is the predominant conduction mechanism. The temperature dependence of σac(ω) showed a linear increase with the increase in temperature at different frequencies. The ac activation energy was determined at different frequencies. Dielectric data were analyzed using complex permittivity and complex electric modulus for bulk Furfurylidenemalononitrile at various temperatures.

  1. Pixel-based CTE Correction of ACS/WFC: Modifications To The ACS Calibration Pipeline (CALACS)

    NASA Astrophysics Data System (ADS)

    Smith, Linda J.; Anderson, J.; Armstrong, A.; Avila, R.; Bedin, L.; Chiaberge, M.; Davis, M.; Ferguson, B.; Fruchter, A.; Golimowski, D.; Grogin, N.; Hack, W.; Lim, P. L.; Lucas, R.; Maybhate, A.; McMaster, M.; Ogaz, S.; Suchkov, A.; Ubeda, L.

    2012-01-01

    The Advanced Camera for Surveys (ACS) was installed on the Hubble Space Telescope (HST) nearly ten years ago. Over the last decade, continuous exposure to the harsh radiation environment has degraded the charge transfer efficiency (CTE) of the CCDs. The worsening CTE impacts the science that can be obtained by altering the photometric, astrometric and morphological characteristics of sources, particularly those farthest from the readout amplifiers. To ameliorate these effects, Anderson & Bedin (2010, PASP, 122, 1035) developed a pixel-based empirical approach to correcting ACS data by characterizing the CTE profiles of trails behind warm pixels in dark exposures. The success of this technique means that it is now possible to correct full-frame ACS/WFC images for CTE degradation in the standard data calibration and reduction pipeline CALACS. Over the past year, the ACS team at STScI has developed, refined and tested the new software. The details of this work are described in separate posters. The new code is more effective at low flux levels (< 50 electrons) than the original Anderson & Bedin code, and employs a more accurate time and temperature dependence for CTE. The new CALACS includes the automatic removal of low-level bias stripes (produced by the post-repair ACS electronics) and pixel-based CTE correction. In addition to the standard cosmic ray corrected, flat-fielded and drizzled data products (crj, flt and drz files) there are three new equivalent files (crc, flc and drc) which contain the CTE-corrected data products. The user community will be able to choose whether to use the standard or CTE-corrected products.

  2. Assay Methods for ACS Activity and ACS Phosphorylation by MAP Kinases In Vitro and In Vivo.

    PubMed

    Han, Xiaomin; Li, Guojing; Zhang, Shuqun

    2017-01-01

    Ethylene, a gaseous phytohormone, has profound effects on plant growth, development, and adaptation to the environment. Ethylene-regulated processes begin with the induction of ethylene biosynthesis. There are two key steps in ethylene biosynthesis. The first is the biosynthesis of 1-aminocyclopropane-1-carboxylic acid (ACC) from S-Adenosyl-Methionine (SAM), a common precursor in many metabolic pathways, which is catalyzed by ACC synthase (ACS). The second is the oxidative cleavage of ACC to form ethylene under the action of ACC oxidase (ACO). ACC biosynthesis is the committing and generally the rate-limiting step in ethylene biosynthesis. As a result, characterizing the cellular ACS activity and understanding its regulation are important. In this chapter, we detail the methods used to measure, (1) the enzymatic activity of both recombinant and native ACS proteins, and (2) the phosphorylation of ACS protein by mitogen-activated protein kinases (MAPKs) in vivo and in vitro.

  3. Laser-guided energetic discharges over large air gaps by electric-field enhanced plasma filaments

    NASA Astrophysics Data System (ADS)

    Théberge, Francis; Daigle, Jean-François; Kieffer, Jean-Claude; Vidal, François; Châteauneuf, Marc

    2017-01-01

    Recent works on plasma channels produced during the propagation of ultrashort and intense laser pulses in air demonstrated the guiding of electric discharges along the laser path. However, the short plasma lifetime limits the length of the laser-guided discharge. In this paper, the conductivity and lifetime of long plasma channels produced by ultrashort laser pulses is enhanced efficiently over many orders of magnitude by the electric field of a hybrid AC-DC high-voltage source. The AC electric pulse from a Tesla coil allowed to stimulate and maintain the highly conductive channel during few milliseconds in order to guide a subsequent 500 times more energetic discharge from a 30-kV DC source. This DC discharge was laser-guided over an air gap length of two metres, which is more than two orders of magnitude longer than the expected natural discharge length. Long plasma channel induced by laser pulses and stimulated by an external high-voltage source opens the way for wireless and efficient transportation of energetic current pulses over long air gaps and potentially for guiding lightning.

  4. Laser-guided energetic discharges over large air gaps by electric-field enhanced plasma filaments

    PubMed Central

    Théberge, Francis; Daigle, Jean-François; Kieffer, Jean-Claude; Vidal, François; Châteauneuf , Marc

    2017-01-01

    Recent works on plasma channels produced during the propagation of ultrashort and intense laser pulses in air demonstrated the guiding of electric discharges along the laser path. However, the short plasma lifetime limits the length of the laser-guided discharge. In this paper, the conductivity and lifetime of long plasma channels produced by ultrashort laser pulses is enhanced efficiently over many orders of magnitude by the electric field of a hybrid AC-DC high-voltage source. The AC electric pulse from a Tesla coil allowed to stimulate and maintain the highly conductive channel during few milliseconds in order to guide a subsequent 500 times more energetic discharge from a 30-kV DC source. This DC discharge was laser-guided over an air gap length of two metres, which is more than two orders of magnitude longer than the expected natural discharge length. Long plasma channel induced by laser pulses and stimulated by an external high-voltage source opens the way for wireless and efficient transportation of energetic current pulses over long air gaps and potentially for guiding lightning. PMID:28053312

  5. Lamin A/C Depletion Enhances DNA Damage-Induced Stalled Replication Fork Arrest

    PubMed Central

    Singh, Mayank; Hunt, Clayton R.; Pandita, Raj K.; Kumar, Rakesh; Yang, Chin-Rang; Horikoshi, Nobuo; Bachoo, Robert; Serag, Sara; Story, Michael D.; Shay, Jerry W.; Powell, Simon N.; Gupta, Arun; Jeffery, Jessie; Pandita, Shruti; Chen, Benjamin P. C.; Deckbar, Dorothee; Löbrich, Markus; Yang, Qin; Khanna, Kum Kum; Worman, Howard J.

    2013-01-01

    The human LMNA gene encodes the essential nuclear envelope proteins lamin A and C (lamin A/C). Mutations in LMNA result in altered nuclear morphology, but how this impacts the mechanisms that maintain genomic stability is unclear. Here, we report that lamin A/C-deficient cells have a normal response to ionizing radiation but are sensitive to agents that cause interstrand cross-links (ICLs) or replication stress. In response to treatment with ICL agents (cisplatin, camptothecin, and mitomycin), lamin A/C-deficient cells displayed normal γ-H2AX focus formation but a higher frequency of cells with delayed γ-H2AX removal, decreased recruitment of the FANCD2 repair factor, and a higher frequency of chromosome aberrations. Similarly, following hydroxyurea-induced replication stress, lamin A/C-deficient cells had an increased frequency of cells with delayed disappearance of γ-H2AX foci and defective repair factor recruitment (Mre11, CtIP, Rad51, RPA, and FANCD2). Replicative stress also resulted in a higher frequency of chromosomal aberrations as well as defective replication restart. Taken together, the data can be interpreted to suggest that lamin A/C has a role in the restart of stalled replication forks, a prerequisite for initiation of DNA damage repair by the homologous recombination pathway, which is intact in lamin A/C-deficient cells. We propose that lamin A/C is required for maintaining genomic stability following replication fork stalling, induced by either ICL damage or replicative stress, in order to facilitate fork regression prior to DNA damage repair. PMID:23319047

  6. Water Treatment Using Plasma Discharge with Variation of Electrode Materials

    NASA Astrophysics Data System (ADS)

    Chanan, N.; Kusumandari; Saraswati, T. E.

    2018-03-01

    This research studied water treatment using plasma discharge. Plasma generated in this study produced active species that played a role in organic compound decomposition. The plasma reactor consisted of two needle electrodes made from stainless steel, tungsten, aluminium and grafit. It placed approximately 2 mm above the solution and connected with high-AC voltage. A solution of methylene blue used as an organic solution model. Plasma treatment times were 2, 4, 6, 8 and 10 min. The absorbance, temperature and pH of the solution were measured before and after treatment using various electrodes. The best electrode used in plasma discharging for methylene blue absorbance reduction was the graphite electrode, which provided the highest degradation efficiency of 98% at 6 min of treatment time.

  7. Lipopolysaccharide-induced pulmonary endothelial barrier disruption and lung edema: critical role for bicarbonate stimulation of AC10.

    PubMed

    Nickols, Jordan; Obiako, Boniface; Ramila, K C; Putinta, Kevin; Schilling, Sarah; Sayner, Sarah L

    2015-12-15

    Bacteria-induced sepsis is a common cause of pulmonary endothelial barrier dysfunction and can progress toward acute respiratory distress syndrome. Elevations in intracellular cAMP tightly regulate pulmonary endothelial barrier integrity; however, cAMP signals are highly compartmentalized: whether cAMP is barrier-protective or -disruptive depends on the compartment (plasma membrane or cytosol, respectively) in which the signal is generated. The mammalian soluble adenylyl cyclase isoform 10 (AC10) is uniquely stimulated by bicarbonate and is expressed in pulmonary microvascular endothelial cells (PMVECs). Elevated extracellular bicarbonate increases cAMP in PMVECs to disrupt the endothelial barrier and increase the filtration coefficient (Kf) in the isolated lung. We tested the hypothesis that sepsis-induced endothelial barrier disruption and increased permeability are dependent on extracellular bicarbonate and activation of AC10. Our findings reveal that LPS-induced endothelial barrier disruption is dependent on extracellular bicarbonate: LPS-induced barrier failure and increased permeability are exacerbated in elevated bicarbonate compared with low extracellular bicarbonate. The AC10 inhibitor KH7 attenuated the bicarbonate-dependent LPS-induced barrier disruption. In the isolated lung, LPS failed to increase Kf in the presence of minimal perfusate bicarbonate. An increase in perfusate bicarbonate to the physiological range (24 mM) revealed the LPS-induced increase in Kf, which was attenuated by KH7. Furthermore, in PMVECs treated with LPS for 6 h, there was a dose-dependent increase in AC10 expression. Thus these findings reveal that LPS-induced pulmonary endothelial barrier failure requires bicarbonate activation of AC10. Copyright © 2015 the American Physiological Society.

  8. Lipopolysaccharide-induced pulmonary endothelial barrier disruption and lung edema: critical role for bicarbonate stimulation of AC10

    PubMed Central

    Nickols, Jordan; Obiako, Boniface; Ramila, K. C.; Putinta, Kevin; Schilling, Sarah

    2015-01-01

    Bacteria-induced sepsis is a common cause of pulmonary endothelial barrier dysfunction and can progress toward acute respiratory distress syndrome. Elevations in intracellular cAMP tightly regulate pulmonary endothelial barrier integrity; however, cAMP signals are highly compartmentalized: whether cAMP is barrier-protective or -disruptive depends on the compartment (plasma membrane or cytosol, respectively) in which the signal is generated. The mammalian soluble adenylyl cyclase isoform 10 (AC10) is uniquely stimulated by bicarbonate and is expressed in pulmonary microvascular endothelial cells (PMVECs). Elevated extracellular bicarbonate increases cAMP in PMVECs to disrupt the endothelial barrier and increase the filtration coefficient (Kf) in the isolated lung. We tested the hypothesis that sepsis-induced endothelial barrier disruption and increased permeability are dependent on extracellular bicarbonate and activation of AC10. Our findings reveal that LPS-induced endothelial barrier disruption is dependent on extracellular bicarbonate: LPS-induced barrier failure and increased permeability are exacerbated in elevated bicarbonate compared with low extracellular bicarbonate. The AC10 inhibitor KH7 attenuated the bicarbonate-dependent LPS-induced barrier disruption. In the isolated lung, LPS failed to increase Kf in the presence of minimal perfusate bicarbonate. An increase in perfusate bicarbonate to the physiological range (24 mM) revealed the LPS-induced increase in Kf, which was attenuated by KH7. Furthermore, in PMVECs treated with LPS for 6 h, there was a dose-dependent increase in AC10 expression. Thus these findings reveal that LPS-induced pulmonary endothelial barrier failure requires bicarbonate activation of AC10. PMID:26475732

  9. Gamma-irradiation produces active chlorine species (ACS) in physiological solutions: Secoisolariciresinol diglucoside (SDG) scavenges ACS - A novel mechanism of DNA radioprotection

    PubMed Central

    Mishra, Om P.; Popov, Anatoliy V.; Pietrofesa, Ralph A.; Christofidou-Solomidou, Melpo

    2017-01-01

    Background Secoisolariciresinol diglucoside (SDG), the main lignan in whole grain flaxseed, is a potent antioxidant and free radical scavenger with known radioprotective properties. However, the exact mechanism of SDG radioprotection is not well understood. The current study identified a novel mechanism of DNA radioprotection by SDG in physiological solutions by scavenging active chlorine species (ACS) and reducing chlorinated nucleobases. Methods The ACS scavenging activity of SDG was determined using two highly specific fluoroprobes: hypochlorite-specific 3′-(p-aminophenyl) fluorescein (APF) and hydroxyl radical-sensitive 3′-(p-hydroxyphenyl) fluorescein (HPF). Dopamine, an SDG structural analog, was used for proton 1H NMR studies to trap primary ACS radicals. Taurine N-chlorination was determined to demonstrate radiation-induced generation of hypochlorite, a secondary ACS. DNA protection was assessed by determining the extent of DNA fragmentation and plasmid DNA relaxation following exposure to ClO− and radiation. Purine base chlorination by ClO− and γ-radiation was determined by using 2-aminopurine (2-AP), a fluorescent analog of 6-aminopurine. Results: Chloride anions (Cl−) consumed >90% of hydroxyl radicals in physiological solutions produced by γ-radiation resulting in ACS formation, which was detected by 1H NMR. Importantly, SDG scavenged hypochlorite- and γ-radiation-induced ACS. In addition, SDG blunted ACS-induced fragmentation of calf thymus DNA and plasmid DNA relaxation. SDG treatment before or after ACS exposure decreased the ClO− or γ-radiation-induced chlorination of 2-AP. Exposure to γ-radiation resulted in increased taurine chlorination, indicative of ClO− generation. NMR studies revealed formation of primary ACS radicals (chlorine atoms (Cl•) and dichloro radical anions (Cl2−•)), which were trapped by SDG and its structural analog dopamine. Conclusion We demonstrate that γ-radiation induces the generation of ACS in

  10. Gamma-irradiation produces active chlorine species (ACS) in physiological solutions: Secoisolariciresinol diglucoside (SDG) scavenges ACS - A novel mechanism of DNA radioprotection.

    PubMed

    Mishra, Om P; Popov, Anatoliy V; Pietrofesa, Ralph A; Christofidou-Solomidou, Melpo

    2016-09-01

    Secoisolariciresinol diglucoside (SDG), the main lignan in whole grain flaxseed, is a potent antioxidant and free radical scavenger with known radioprotective properties. However, the exact mechanism of SDG radioprotection is not well understood. The current study identified a novel mechanism of DNA radioprotection by SDG in physiological solutions by scavenging active chlorine species (ACS) and reducing chlorinated nucleobases. The ACS scavenging activity of SDG was determined using two highly specific fluoroprobes: hypochlorite-specific 3'-(p-aminophenyl) fluorescein (APF) and hydroxyl radical-sensitive 3'-(p-hydroxyphenyl) fluorescein (HPF). Dopamine, an SDG structural analog, was used for proton (1)H NMR studies to trap primary ACS radicals. Taurine N-chlorination was determined to demonstrate radiation-induced generation of hypochlorite, a secondary ACS. DNA protection was assessed by determining the extent of DNA fragmentation and plasmid DNA relaxation following exposure to ClO(-) and radiation. Purine base chlorination by ClO(-) and γ-radiation was determined by using 2-aminopurine (2-AP), a fluorescent analog of 6-aminopurine. Chloride anions (Cl(-)) consumed >90% of hydroxyl radicals in physiological solutions produced by γ-radiation resulting in ACS formation, which was detected by (1)H NMR. Importantly, SDG scavenged hypochlorite- and γ-radiation-induced ACS. In addition, SDG blunted ACS-induced fragmentation of calf thymus DNA and plasmid DNA relaxation. SDG treatment before or after ACS exposure decreased the ClO(-) or γ-radiation-induced chlorination of 2-AP. Exposure to γ-radiation resulted in increased taurine chlorination, indicative of ClO(-) generation. NMR studies revealed formation of primary ACS radicals (chlorine atoms (Cl) and dichloro radical anions (Cl2¯)), which were trapped by SDG and its structural analog dopamine. We demonstrate that γ-radiation induces the generation of ACS in physiological solutions. SDG treatment scavenged

  11. Plasma heating, electric fields and plasma flow by electron beam ionospheric injection

    NASA Technical Reports Server (NTRS)

    Winckler, J. R.; Erickson, K. N.

    1990-01-01

    The electric fields and the floating potentials of a Plasma Diagnostics Payload (PDP) located near a powerful electron beam injected from a large sounding rocket into the auroral zone ionosphere have been studied. As the PDP drifted away from the beam laterally, it surveyed a region of hot plasma extending nearly to 60 m radius. Large polarization electric fields transverse to B were imbedded in this hot plasma, which displayed large ELF wave variations and also an average pattern which has led to a model of the plasma flow about the negative line potential of the beam resembling a hydrodynamic vortex in a uniform flow field. Most of the present results are derived from the ECHO 6 sounding rocket mission.

  12. Superconductor coil geometry and ac losses

    NASA Technical Reports Server (NTRS)

    Pierce, T. V., Jr.; Zapata, R. N.

    1976-01-01

    An empirical relation is presented which allows simple computation of volume-averaged winding fields from central fields for coils of small rectangular cross sections. This relation suggests that, in certain applications, ac-loss minimization can be accomplished by use of low winding densities, provided that hysteresis losses are independent of winding density. The ac-loss measurements on coils wound of twisted multifilamentary composite superconductors show no significant dependence on ac losses on winding density, thus permitting the use of winding density as an independent design parameter in loss minimization.

  13. Defects in the C. elegans acyl-CoA Synthase, acs-3, and Nuclear Hormone Receptor, nhr-25, Cause Sensitivity to Distinct, but Overlapping Stresses

    PubMed Central

    Ward, Jordan D.; Mullaney, Brendan; Schiller, Benjamin J.; He, Le D.; Petnic, Sarah E.; Couillault, Carole; Pujol, Nathalie; Bernal, Teresita U.; Van Gilst, Marc R.; Ashrafi, Kaveh; Ewbank, Jonathan J.; Yamamoto, Keith R.

    2014-01-01

    Metazoan transcription factors control distinct networks of genes in specific tissues, yet understanding how these networks are integrated into physiology, development, and homeostasis remains challenging. Inactivation of the nuclear hormone receptor nhr-25 ameliorates developmental and metabolic phenotypes associated with loss of function of an acyl-CoA synthetase gene, acs-3. ACS-3 activity prevents aberrantly high NHR-25 activity. Here, we investigated this relationship further by examining gene expression patterns following acs-3 and nhr-25 inactivation. Unexpectedly, we found that the acs-3 mutation or nhr-25 RNAi resulted in similar transcriptomes with enrichment in innate immunity and stress response gene expression. Mutants of either gene exhibited distinct sensitivities to pathogens and environmental stresses. Only nhr-25 was required for wild-type levels of resistance to the bacterial pathogen P. aeruginosa and only acs-3 was required for wild-type levels of resistance to osmotic stress and the oxidative stress generator, juglone. Inactivation of either acs-3 or nhr-25 compromised lifespan and resistance to the fungal pathogen D. coniospora. Double mutants exhibited more severe defects in the lifespan and P. aeruginosa assays, but were similar to the single mutants in other assays. Finally, acs-3 mutants displayed defects in their epidermal surface barrier, potentially accounting for the observed sensitivities. Together, these data indicate that inactivation of either acs-3 or nhr-25 causes stress sensitivity and increased expression of innate immunity/stress genes, most likely by different mechanisms. Elevated expression of these immune/stress genes appears to abrogate the transcriptional signatures relevant to metabolism and development. PMID:24651852

  14. Simulations of Atmospheric Plasma Arcs

    NASA Astrophysics Data System (ADS)

    Pearcy, Jacob; Chopra, Nirbhav; Jaworski, Michael

    2017-10-01

    We present the results of computer simulation of cylindrical plasma arcs with characteristics similar to those predicted to be relevant in magnetohydrodynamic (MHD) power conversion systems. These arcs, with core temperatures on the order of 1 eV, place stringent limitations on the lifetime of conventional electrodes used in such systems, suggesting that a detailed analysis of arc characteristics will be crucial in designing more robust electrode systems. Simulations utilize results from NASA's Chemical Equilibrium with Applications (CEA) program to solve the Elenbaas-Heller equation in a variety of plasma compositions, including approximations of coal-burning plasmas as well as pure gas discharges. The effect of carbon dioxide injection on arc characteristics, emulating discharges from molten carbonate salt electrodes, is also analyzed. Results include radial temperature profiles, composition maps, and current-voltage (IV) characteristics of these arcs. Work supported by DOE contract DE-AC02-09CH11466.

  15. DC-biased AC-electroosmotic and AC-electrothermal flow mixing in microchannels.

    PubMed

    Ng, Wee Yang; Goh, Shireen; Lam, Yee Cheong; Yang, Chun; Rodríguez, Isabel

    2009-03-21

    This paper presents a novel approach of mixing two laminar flowing streams in microchannels. The mixer consists of a pair of electrodes disposed along a fluidic channel. By energizing the electrodes with a DC-biased (2.5 V) AC voltage (20 Vpp), an electrokinetic flow is induced with a flow profile perpendicular to that of the incoming laminar streams of liquids to be mixed. As a result, the flow lines of the incoming streams and the induced flow are forced to crossover and very efficient stirring and mixing at short mixing length can be achieved. The mixer can be operated from the AC-electroosmotic (ACEO) (sigma=1 mS/m, f=100 kHz) to the AC-electrothermal (ACET) (sigma=500 mS/m, f=500 kHz) flow regimes. The mixing efficiency in the ACEO regime was 92%, with a mixing length of 600 microm (Q=2 microL/min), an estimated mixing time of 69 ms and an induced ACEO flow velocity of approximately 725 microm/s. The mixing efficiency in the ACET regime was 65% for a mixing length of approximately 1200 microm. The mixer is efficient and suitable for mixing reagents in a fluid media from low to high conductivity as required in diverse microfluidic applications.

  16. Experimental Validation Plan for the Xolotl Plasma-Facing Component Simulator Using Tokamak Sample Exposures

    NASA Astrophysics Data System (ADS)

    Chan, V. S.; Wong, C. P. C.; McLean, A. G.; Luo, G. N.; Wirth, B. D.

    2013-10-01

    The Xolotl code under development by PSI-SciDAC will enhance predictive modeling capability of plasma-facing materials under burning plasma conditions. The availability and application of experimental data to compare to code-calculated observables are key requirements to validate the breadth and content of physics included in the model and ultimately gain confidence in its results. A dedicated effort has been in progress to collect and organize a) a database of relevant experiments and their publications as previously carried out at sample exposure facilities in US and Asian tokamaks (e.g., DIII-D DiMES, and EAST MAPES), b) diagnostic and surface analysis capabilities available at each device, and c) requirements for future experiments with code validation in mind. The content of this evolving database will serve as a significant resource for the plasma-material interaction (PMI) community. Work supported in part by the US Department of Energy under GA-DE-SC0008698, DE-AC52-07NA27344 and DE-AC05-00OR22725.

  17. Partially Ionized Plasmas in Astrophysics

    NASA Astrophysics Data System (ADS)

    Ballester, José Luis; Alexeev, Igor; Collados, Manuel; Downes, Turlough; Pfaff, Robert F.; Gilbert, Holly; Khodachenko, Maxim; Khomenko, Elena; Shaikhislamov, Ildar F.; Soler, Roberto; Vázquez-Semadeni, Enrique; Zaqarashvili, Teimuraz

    2018-03-01

    Partially ionized plasmas are found across the Universe in many different astrophysical environments. They constitute an essential ingredient of the solar atmosphere, molecular clouds, planetary ionospheres and protoplanetary disks, among other environments, and display a richness of physical effects which are not present in fully ionized plasmas. This review provides an overview of the physics of partially ionized plasmas, including recent advances in different astrophysical areas in which partial ionization plays a fundamental role. We outline outstanding observational and theoretical questions and discuss possible directions for future progress.

  18. Spectroscopic Determination of the AC Voltammetric Response.

    DTIC Science & Technology

    1984-01-06

    characterization of electrode processes. More recently, with the advent of linear sweep cyclic AC voltanmetry(12’ 13), it has been shown that AC methods...implemented with the same instrumentation ( 7 ) as previously used in MSRS and retains both the qualitative and quantitative utility of linear sweep ...voltammetric response (eg. peak width at balf-height, peak separation and cross-over potential in cyclic AC voltametry ) apply equally well to the SACRS

  19. THERMIONIC AC GENERATION

    DTIC Science & Technology

    is shown that the maximum ac efficiency is equal to approximately 70% of the corresponding dc value. An illustrative example, including a proposed design for a rather unconventional transformer, is appended. (Author)

  20. 78 FR 49318 - Availability of Draft Advisory Circular (AC) 90-106A and AC 20-167A

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-13

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Docket No FAA-2013-0485] Availability of Draft Advisory Circular (AC) 90-106A and AC 20- 167A AGENCY: Federal Aviation Administration..., Federal Aviation Administration, 800 Independence Avenue SW., Washington, DC 20591; telephone (202) 385...

  1. Development of a 100 kW plasma torch for plasma assisted combustion of low heating value fuels

    NASA Astrophysics Data System (ADS)

    Takali, S.; Fabry, F.; Rohani, V.; Cauneau, F.; Fulcheri, L.

    2014-11-01

    Most thermal power plants need an auxiliary power source to (i) heat-up the boiler during start up phases before reaching autonomy power and (ii) sustain combustion at low load. This supplementary power is commonly provided with high LHV fossil fuel burners which increases operational expenses and disables the use of anti-pollutant filters. A Promising alternative is under development and consists in high temperature plasma assisted AC electro-burners. In this paper, the development of a new 100 kW three phase plasma torch with graphite electrodes is detailed. This plasma torch is working at atmospheric pressure with air as plasma gas and has three-phase power supply and working at 680 Hz. The nominal air flow rate is 60 Nm3.h-1 and the outlet gas temperature is above 2 500 K. At the beginning, graphite electrodes erosion by oxidizing medium was studied and controlling parameters were identified through parametric set of experiments and tuned for optimal electrodes life time. Then, a new 3-phase plasma torch design was modelled and simulated on ANSYS platform. The characteristics of the plasma flow and its interaction with the environing elements of the torch are detailed hereafter.

  2. AC impedance and conductivity study of alkali salt form [of] perfluorosulfonate ionomer membranes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zaluski, C.S.; Xu, G.

    1994-02-01

    AC impedance studies were performed on Na+ and K+ alkali salt forms of the short sidechain perfluorosulfonate ionomer (PFSI) membrane films. With impressive performances of 4 A/cm[sup 2] current density and power densities near 2.5 W/cm[sup 2], the acid forms of these short sidechain PFSI are very promising candidates for use in fuel cells for future electric vehicles. Since, at present, little is known about the exact transport mechanisms for the ionic species within PFSIs, an ac impedance study of the Na+ and K+ forms has been performed. It is hoped that this will provide some insight and understanding ofmore » the transport mechanisms in the PFSI and thus will aid in the development and optimization of fuel cells. Results suggest that there are marked differences with respect to host environments within the Dow membrane as compared to Nafion[reg sign] long sidechain PFSI membrane films. Impedance spectra of the Dow salt form membranes displaying two distinct relaxation peaks while the spectra for all forms of Nafion reveal only a single peak. This second low temperature peak in the Dow membrane has been attributed to a much larger [OH[sup [minus

  3. Differential Roles of AC2 and AC4 of Cassava Geminiviruses in Mediating Synergism and Suppression of Posttranscriptional Gene Silencing

    PubMed Central

    Vanitharani, Ramachandran; Chellappan, Padmanabhan; Pita, Justin S.; Fauquet, Claude M.

    2004-01-01

    Posttranscriptional gene silencing (PTGS) in plants is a natural defense mechanism against virus infection. In mixed infections, virus synergism is proposed to result from suppression of the host defense mechanism by the viruses. Synergistic severe mosaic disease caused by simultaneous infection with isolates of the Cameroon strain of African cassava mosaic virus (ACMV-[CM]) and East African cassava mosaic Cameroon virus (EACMCV) in cassava and tobacco is characterized by a dramatic increase in symptom severity and a severalfold increase in viral-DNA accumulation by both viruses compared to that in singly infected plants. Here, we report that synergism between ACMV-[CM] and EACMCV is a two-way process, as the presence of the DNA-A component of ACMV-[CM] or EACMCV in trans enhanced the accumulation of viral DNA of EACMCV and ACMV-[CM], respectively, in tobacco BY-2 protoplasts. Furthermore, transient expression of ACMV-[CM] AC4 driven by the Cauliflower mosaic virus 35S promoter (p35S-AC4) enhanced EACMCV DNA accumulation by ∼8-fold in protoplasts, while p35S-AC2 of EACMCV enhanced ACMV-[CM] DNA accumulation, also by ∼8-fold. An Agrobacterium-based leaf infiltration assay determined that ACMV-[CM] AC4 and EACMCV AC2, the putative synergistic genes, were able to suppress PTGS induced by green fluorescent protein (GFP) and eliminated the short interfering RNAs associated with PTGS, with a correlated increase in GFP mRNA accumulation. In addition, we have identified AC4 of Sri Lankan cassava mosaic virus and AC2 of Indian cassava mosaic virus as suppressors of PTGS, indicating that geminiviruses evolved differently in regard to interaction with the host. The specific and different roles played by these AC2 and AC4 proteins of cassava geminiviruses in regulating anti-PTGS activity and their relation to synergism are discussed. PMID:15308741

  4. 21 CFR 880.6320 - AC-powered medical examination light.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false AC-powered medical examination light. 880.6320... Miscellaneous Devices § 880.6320 AC-powered medical examination light. (a) Identification. An AC-powered medical examination light is an AC-powered device intended for medical purposes that is used to illuminate body...

  5. High-frequency ac power distribution in Space Station

    NASA Technical Reports Server (NTRS)

    Tsai, Fu-Sheng; Lee, Fred C. Y.

    1990-01-01

    A utility-type 20-kHz ac power distribution system for the Space Station, employing resonant power-conversion techniques, is presented. The system converts raw dc voltage from photovoltaic cells or three-phase LF ac voltage from a solar dynamic generator into a regulated 20-kHz ac voltage for distribution among various loads. The results of EASY5 computer simulations of the local and global performance show that the system has fast response and good transient behavior. The ac bus voltage is effectively regulated using the phase-control scheme, which is demonstrated with both line and load variations. The feasibility of paralleling the driver-module outputs is illustrated with the driver modules synchronized and sharing a common feedback loop. An HF sinusoidal ac voltage is generated in the three-phase ac input case, when the driver modules are phased 120 deg away from one another and their outputs are connected in series.

  6. The Material Plasma Exposure eXperiment (MPEX)

    NASA Astrophysics Data System (ADS)

    Rapp, J.; Biewer, T. M.; Bigelow, T. S.; Canik, J.; Caughman, J. B. O.; Duckworth, R. C.; Goulding, R. H.; Hillis, D. L.; Lore, J. D.; Lumsdaine, A.; McGinnis, W. D.; Meitner, S. J.; Owen, L. W.; Shaw, G. C.; Luo, G.-N.

    2014-10-01

    Next generation plasma generators have to be able to access the plasma conditions expected on the divertor targets in ITER and future devices. The Material Plasma Exposure eXperiment (MPEX) will address this regime with electron temperatures of 1--10 eV and electron densities of 1021--1020 m-3. The resulting heat fluxes are about 10 MW/m2. MPEX is designed to deliver those plasma conditions with a novel Radio Frequency plasma source able to produce high density plasmas and heat electron and ions separately with Electron Bernstein Wave (EBW) heating and Ion Cyclotron Resonance Heating (ICRH). Preliminary modeling has been used for pre-design studies of MPEX. MPEX will be capable to expose neutron irradiated samples. In this concept targets will be irradiated in ORNL's High Flux Isotope Reactor (HFIR) or possibly at the Spallation Neutron Source (SNS) and then subsequently (after a sufficient long cool-down period) exposed to fusion reactor relevant plasmas in MPEX. The current state of the pre-design of MPEX including the concept of handling irradiated samples will be presented. ORNL is managed by UT-Battelle, LLC, for the U.S. DOE under Contract DE-AC-05-00OR22725.

  7. BacMam virus-based surface display of the infectious bronchitis virus (IBV) S1 glycoprotein confers strong protection against virulent IBV challenge in chickens.

    PubMed

    Zhang, Jie; Chen, Xiao-Wei; Tong, Tie-Zhu; Ye, Yu; Liao, Ming; Fan, Hui-Ying

    2014-02-03

    Avian infectious bronchitis virus (IBV) is associated with production inefficiencies in domestic fowl, and causes massive economic losses to the poultry industry worldwide. Progress has been made in designing novel and efficient candidate vaccines to control IBV infection. BacMam virus, a modified baculovirus mediating transgene expression under the control of a mammalian promoter, has emerged as a versatile and safe vector during vaccine development. In previous work, we generated the BacMam virus Ac-CMV-S1, which expressed the S1 glycoprotein of IBV-M41. We showed that Ac-CMV-S1 induced excellent cellular immunity, but did not confer adequate protection in chickens compared with the conventional inactivated vaccine. In the current study, we generated an improved BacMam virus, BV-Dual-S1. This virus displayed the S1 glycoprotein on the baculovirus envelope, and was capable of expressing it in mammalian cells. BV-Dual-S1 elicited stronger humoral and cell-mediated immune responses, and showed greater capacity for induction of cytotoxic T lymphocyte responses, compared with Ac-CMV-S1 in specific pathogen-free chickens. A significant difference was not observed for protection rates between chickens immunized with BV-Dual-S1 (83%) or inactivated vaccine (89%) following challenge with virulent IBV-M41. Our findings show that the protective efficacy of BV-Dual-S1 could be significantly enhanced by baculovirus display technology. BacMam virus-based surface display strategies could serve as effective tools in designing vaccines against IB and other infectious diseases. Copyright © 2013. Published by Elsevier Ltd.

  8. A new therapeutic approach for type 1 diabetes: rationale for GNbAC1 an anti-HERV-W-Env monoclonal antibody.

    PubMed

    Curtin, Francois; Bernard, Corinne; Levet, Sandrine; Perron, Hervé; Porchet, Hervé; Médina, Julie; Malpass, Sam; Lloyd, David; Simpson, Richard

    2018-05-10

    We describe a newly identified therapeutic target for type 1 diabetes: an envelope protein of endogenous retroviral origin called Human Endogenous Retrovirus W Envelope (HERV-W-Env). HERV-W-Env was found to be detected in the blood of around 60% of type 1 diabetes (T1D) patients and is expressed in acinar pancreatic cells of 75% of T1D patients at post-mortem examination. Preclinical experiments showed that this protein displays direct cytotoxicity on human β-islet cells. In vivo HERV-W-Env impairs the insulin and glucose metabolism in transgenic mice expressing HERV-W-Env. GNbAC1, an IgG4 monoclonal antibody has been developed to specifically target HERV-W-Env and to neutralize the effect of HERV-W-Env in vitro and in vivo. GNbAC1 is currently in clinical development for multiple sclerosis and more than 300 subjects have been administered with GNbAC1 so far. GNbAC1 is now tested in T1D in the RAINBOW-T1D study: a randomized placebo controlled study with the objective of showing the safety and pharmacodynamics response of GNbAC1 in patients suffering from T1D with a maximum duration of 4 years. GNbAC1 is tested versus placebo at the dose of 6 mg/kg in 60 patients during 6 repeated administrations during 6 months, a 6-month open-label extension will follow. The primary endpoint will assess safety and secondary endpoints the pharmacodynamic responses to GNbAC1. GNbAC1 targeting HERV-W-Env is currently in clinical development in T1D with the first safety and pharmacodynamic study. If the study results are positive, this may open the door to the development of an innovative non-immunomodulatory disease modifying treatment for T1D. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  9. Industrial Applications of Low Temperature Plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bardsley, J N

    2001-03-15

    The use of low temperature plasmas in industry is illustrated by the discussion of four applications, to lighting, displays, semiconductor manufacturing and pollution control. The type of plasma required for each application is described and typical materials are identified. The need to understand radical formation, ionization and metastable excitation within the discharge and the importance of surface reactions are stressed.

  10. Plasma generators, reactor systems and related methods

    DOEpatents

    Kong, Peter C [Idaho Falls, ID; Pink, Robert J [Pocatello, ID; Lee, James E [Idaho Falls, ID

    2007-06-19

    A plasma generator, reactor and associated systems and methods are provided in accordance with the present invention. A plasma reactor may include multiple sections or modules which are removably coupled together to form a chamber. Associated with each section is an electrode set including three electrodes with each electrode being coupled to a single phase of a three-phase alternating current (AC) power supply. The electrodes are disposed about a longitudinal centerline of the chamber and are arranged to provide and extended arc and generate an extended body of plasma. The electrodes are displaceable relative to the longitudinal centerline of the chamber. A control system may be utilized so as to automatically displace the electrodes and define an electrode gap responsive to measure voltage or current levels of the associated power supply.

  11. Measurements of ion energies during plasma heating of the Proto-MPEX High Intensity Plasma Source

    NASA Astrophysics Data System (ADS)

    Caughman, J. B. O.; Goulding, R. H.; Biewer, T. M.; Bigelow, T. S.; Caneses, J.; Diem, S. J.; Green, D. L.; Isler, R. C.; Rapp, J.; Piotrowicz, P.; Beers, C. J.; Kafle, N.; Showers, M. A.

    2017-10-01

    The Prototype Materials Plasma Exposure eXperiment (Proto-MPEX) is a linear high-intensity RF plasma source that combines a high-density helicon plasma generator with ion and electron heating sections. It is being used to study the physics of heating over-dense plasmas in a linear configuration with the goal of delivering a plasma heat flux of 10 MW/m2 at a target. The helicon plasma is produced by coupling 13.56 MHz RF power at levels >100 kW. Additional heating is provided by ion cyclotron heating (ICH) ( 25 kW) and electron Bernstein wave (EBW) heating ( 25 kW) at 28 GHz. Measurements of the ion energy distribution with a retarding field energy analyzer (RFEA) show an increase in ion energies in the edge of the plasma when ICH is applied, which is consistent with COMSOL modeling of the power deposition from the antenna. Views of the target plate with an infrared camera show an increase in the surface temperature at large radii during ICH, and these areas map back to magnetic field lines near the antenna. The change in the power deposition at the target during ICH is compared with Thomson Scattering and RFEA measurements near the target. ORNL is managed by UT-Battelle, LLC, for the U.S. DOE under contract DE-AC-05-00OR22725.

  12. Transcranial Alternating Current Stimulation (tACS) Mechanisms and Protocols

    PubMed Central

    Tavakoli, Amir V.; Yun, Kyongsik

    2017-01-01

    Perception, cognition and consciousness can be modulated as a function of oscillating neural activity, while ongoing neuronal dynamics are influenced by synaptic activity and membrane potential. Consequently, transcranial alternating current stimulation (tACS) may be used for neurological intervention. The advantageous features of tACS include the biphasic and sinusoidal tACS currents, the ability to entrain large neuronal populations, and subtle control over somatic effects. Through neuromodulation of phasic, neural activity, tACS is a powerful tool to investigate the neural correlates of cognition. The rapid development in this area requires clarity about best practices. Here we briefly introduce tACS and review the most compelling findings in the literature to provide a starting point for using tACS. We suggest that tACS protocols be based on functional brain mechanisms and appropriate control experiments, including active sham and condition blinding. PMID:28928634

  13. Effect of Atmospheric-Pressure Plasma Jet of Neon on 7-Acetoxy-6-(2,3-Dibromopropyl)-4,8-Dimethylcoumarin Molecule

    NASA Astrophysics Data System (ADS)

    Tanışlı, Murat; Taşal, Erol

    2017-06-01

    Atmospheric-pressure low-temperature plasma jets and their applications are a topic of great interest in the fields of physics, technology, and medicine. In this study, the used self-made plasma jet is based on a dielectric barrier discharge (DBD) in neon (Ne) with typical processing parameters, such as frequency in the kHz range and voltage in the kV range. The plasma is characterized by optical emission spectroscopy (OES). These types of plasma can be used in various applications such as surface modification, inactivation of microorganisms, and chemical decomposition. This study is concerned with the Fourier transform infrared spectrum (FT-IR) and ultraviolet-visible (UV-vis) absorption spectroscopy of the large 7-acetoxy-6-(2,3-dibromopropyl)-4,8-dimethylcoumarin molecule (abbreviated as 7AC) dissolved in ethanol and methanol solvents and their modification after atmospheric-pressure plasma treatment (APPT) with the DBD. The research is motivated by the significance of this molecule in different fields of application. Also the changes in the structure are recorded. After APPT, the peak corresponding to the carbonyl bond at a wavenumber of 1715 cm-1 disappears in the IR spectrum of the ethanol solution, and when splitting at a wavenumber of 1405 cm-1 is observed, the peak at 1224 cm-1 is found to disappear after plasma is applied. It is seen new peaks at frequencies of 432 and 655 cm-1 are formed. When the same situation is analyzed for the 7AC molecule dissolved in methanol, a new peak is observed at 1634 cm-1. The intensities of the peaks at 3433 and 2075 cm-1 also increase and there is a large change in the wavenumber at 600 cm-1. In the UV spectra, a significant increase in the absorbance of the 7AC molecule dissolved in ethanol is observed after APPT, whereas a small decrease in the absorbance of the 7AC molecule dissolved in methanol is obtained. Owing to the lack of symmetry, many normal bands of vibrations are mixed.

  14. Filtering of higher-order laser modes using plasma structures

    NASA Astrophysics Data System (ADS)

    Djordjevic, Blagoje; Benedetti, Carlo; Schroeder, Carl; Esarey, Eric; Leemans, Wim

    2017-10-01

    Plasma structures based on leaky channels are proposed to filter higher-order laser mode content. The evolution and propagation of non-Gaussian laser pulses in leaky channels is studied, and it is shown that, for appropriate laser-plasma parameters, the higher-order laser mode content may be removed while the fundamental mode remains well-guided. The behavior of the multi-mode laser pulse is described analytically, including the derivation of the leakage coefficients, and compared to numerical calculations. Gaussian laser pulse propagation, without higher-order mode content, improves guiding in parabolic plasma channels, enabling extended interaction lengths for laser-plasma accelerator applications. This work was supported by the Director, Office of Science, Office of High Energy Physics, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231.

  15. Effect of Cr3+ substitution on AC susceptibility of Ba hexaferrite nanoparticles

    NASA Astrophysics Data System (ADS)

    Slimani, Y.; Baykal, A.; Manikandan, A.

    2018-07-01

    In this study, nano-sized particles of BaCrxFe12-xO19 (0.0 ≤ x ≤ 1.0) hexaferrite were fabricated through citrate auto gel combustion process and the impact of Cr-ion substitution on ac magnetic susceptibility properties of Ba-hexaferrite were explored. X-ray powder diffraction (XRD) measurements approved the purity of prepared samples and showed a reduction of the average crystallite size with increasing the content of Cr. Transmission electron microscopy (TEM) observation indicated the hexagonal morphology of all samples. AC susceptibility measurements displayed a frequency dependence of the magnetic responses. These measurements indicated that there are strong magnetic interactions (which is the highest for BaCr0.3Fe11.7O19 NP) between particles which cause a superspin glass-like (SSG) behavior at low temperatures. Estimating the values of loss power density revealed an increase of loss power density with increasing Cr-substitution element. The relative sensitivity of the prepared MNPs to the variation of applied frequency is very influenced by Cr-substitution and is highest in BaCr0.3Fe11.7O19 MNPs, suggesting that this sample can be considered as magnetic nanomaterial for hyperthermia and for many other applications.

  16. Challenges and solutions in medically managed ACS in the Asia-Pacific region: expert recommendations from the Asia-Pacific ACS Medical Management Working Group.

    PubMed

    Huo, Yong; Thompson, Peter; Buddhari, Wacin; Ge, Junbo; Harding, Scott; Ramanathan, Letchuman; Reyes, Eugenio; Santoso, Anwar; Tam, Li-Wah; Vijayaraghavan, Govindan; Yeh, Hung-I

    2015-03-15

    Acute coronary syndromes (ACS) remain a leading cause of mortality and morbidity in the Asia-Pacific (APAC) region. International guidelines advocate invasive procedures in all but low-risk ACS patients; however, a high proportion of ACS patients in the APAC region receive solely medical management due to a combination of unique geographical, socioeconomic, and population-specific barriers. The APAC ACS Medical Management Working Group recently convened to discuss the ACS medical management landscape in the APAC region. Local and international ACS guidelines and the global and APAC clinical evidence-base for medical management of ACS were reviewed. Challenges in the provision of optimal care for these patients were identified and broadly categorized into issues related to (1) accessibility/systems of care, (2) risk stratification, (3) education, (4) optimization of pharmacotherapy, and (5) cost/affordability. While ACS guidelines clearly represent a valuable standard of care, the group concluded that these challenges can be best met by establishing cardiac networks and individual hospital models/clinical pathways taking into account local risk factors (including socioeconomic status), affordability and availability of pharmacotherapies/invasive facilities, and the nature of local healthcare systems. Potential solutions central to the optimization of ACS medical management in the APAC region are outlined with specific recommendations. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. Infrequent transposition of Ac in lettuce, Lactuca sativa.

    PubMed

    Yang, C H; Ellis, J G; Michelmore, R W

    1993-08-01

    The maize transposable element Activator (Ac) is being used to develop a transposon mutagenesis system in lettuce, Lactuca sativa. Two constructs containing the complete Ac from the waxy-m7 locus of maize were introduced into lettuce and monitored for activity using Southern analysis and PCR amplification of the excision site. No transposition of Ac was detected in over 32 transgenic R1 plants, although these constructs were known to provide frequent transposition in other species. Also, no transposition was observed in later generations. In subsequent experiments, transposition was detected in lettuce calli using constructs that allowed selection for excision events. In these constructs, the neomycin phosphotransferase II gene was interrupted by either Ac or Ds. Excision was detected as the ability of callus to grow on kanamycin. Synthesis of the transposase from the cDNA of Ac expressed from the T-DNA 2' promoter resulted in more frequent excision of Ds than was observed with the wild-type Ac. No excision was observed with Ds in the absence of the transposase. The excision events were confirmed by amplification of the excision site by PCR followed by DNA sequencing. Excision and reintegration were also confirmed by Southern analysis. Ac/Ds is therefore capable of transposition in at least calli of lettuce.

  18. The methylenetetrahydrofolate reductase c.c.677 C>T and c.c.1298 A>C polymorphisms in reproductive failures: Experience from an RSA and RIF study on a Polish population.

    PubMed

    Nowak, Izabela; Bylińska, Aleksandra; Wilczyńska, Karolina; Wiśniewski, Andrzej; Malinowski, Andrzej; Wilczyński, Jacek R; Radwan, Paweł; Radwan, Michał; Barcz, Ewa; Płoski, Rafał; Motak-Pochrzęst, Hanna; Banasik, Małgorzata; Sobczyński, Maciej; Kuśnierczyk, Piotr

    2017-01-01

    Almost 1600 individuals from the Polish population were recruited to this study. Among them 319 were fertile couples, 289 were recurrent spontaneous abortion (RSA) couples, and 131 were in the group of recurrent implantation failure (RIF) following in vitro fertilization. The aim of this study was to evaluate the MTHFR c.c.677 C>T and c.c.1298 A>C polymorphisms' association with RSA and RIF. We used PCR-RFLP with HinfI (677 C>T) and MboII (1298 A>C) digestion. We observed a protective effect of the female AC genotype (OR = 0.64, p = 0.01) and the C allele (AC+CC genotypes; OR = 0.65, p = 0.009) against RSA. Moreover, 1298 AA/677 CT women were more frequent in RSA (31.14%) and RIF (25.20%) groups in comparison to fertile women (22.88%), although this difference was significant only in the case of RSA (p = 0.022, OR = 1.52). Male combined genotype analysis revealed no association with reproductive failure of their partners. Nevertheless, the female/male combination AA/AC of the 1298 polymorphism was more frequent in RSA couples (p = 0.049, OR = 1.49). However, the significant results became insignificant after Bonferroni correction. In addition, analysis of haplotypes showed significantly higher frequency of the C/C haplotype (1298 C/677 C) in the female control group than in the female RSA group (p = 0.03, OR = 0.77). Moreover, the association between elevated homocysteine (Hcy) level in plasma of RSA and RIF women and MTHFR polymorphisms was investigated but did not reveal significant differences. In conclusion, for clinical practice, it is better to check the homocysteine level in plasma and, if the Hcy level is increased, to recommend patients to take folic acid supplements rather than undergo screening of MTHFR for 1298 A>C and 677 C>T polymorphisms.

  19. The methylenetetrahydrofolate reductase c.c.677 C>T and c.c.1298 A>C polymorphisms in reproductive failures: Experience from an RSA and RIF study on a Polish population

    PubMed Central

    Bylińska, Aleksandra; Wilczyńska, Karolina; Wiśniewski, Andrzej; Malinowski, Andrzej; Wilczyński, Jacek R.; Radwan, Paweł; Radwan, Michał; Barcz, Ewa; Płoski, Rafał; Motak-Pochrzęst, Hanna; Banasik, Małgorzata; Sobczyński, Maciej; Kuśnierczyk, Piotr

    2017-01-01

    Almost 1600 individuals from the Polish population were recruited to this study. Among them 319 were fertile couples, 289 were recurrent spontaneous abortion (RSA) couples, and 131 were in the group of recurrent implantation failure (RIF) following in vitro fertilization. The aim of this study was to evaluate the MTHFR c.c.677 C>T and c.c.1298 A>C polymorphisms’ association with RSA and RIF. We used PCR-RFLP with HinfI (677 C>T) and MboII (1298 A>C) digestion. We observed a protective effect of the female AC genotype (OR = 0.64, p = 0.01) and the C allele (AC+CC genotypes; OR = 0.65, p = 0.009) against RSA. Moreover, 1298 AA/677 CT women were more frequent in RSA (31.14%) and RIF (25.20%) groups in comparison to fertile women (22.88%), although this difference was significant only in the case of RSA (p = 0.022, OR = 1.52). Male combined genotype analysis revealed no association with reproductive failure of their partners. Nevertheless, the female/male combination AA/AC of the 1298 polymorphism was more frequent in RSA couples (p = 0.049, OR = 1.49). However, the significant results became insignificant after Bonferroni correction. In addition, analysis of haplotypes showed significantly higher frequency of the C/C haplotype (1298 C/677 C) in the female control group than in the female RSA group (p = 0.03, OR = 0.77). Moreover, the association between elevated homocysteine (Hcy) level in plasma of RSA and RIF women and MTHFR polymorphisms was investigated but did not reveal significant differences. In conclusion, for clinical practice, it is better to check the homocysteine level in plasma and, if the Hcy level is increased, to recommend patients to take folic acid supplements rather than undergo screening of MTHFR for 1298 A>C and 677 C>T polymorphisms. PMID:29073227

  20. Obtaining continuous BrAC/BAC estimates in the field: A hybrid system integrating transdermal alcohol biosensor, Intellidrink smartphone app, and BrAC Estimator software tools.

    PubMed

    Luczak, Susan E; Hawkins, Ashley L; Dai, Zheng; Wichmann, Raphael; Wang, Chunming; Rosen, I Gary

    2018-08-01

    Biosensors have been developed to measure transdermal alcohol concentration (TAC), but converting TAC into interpretable indices of blood/breath alcohol concentration (BAC/BrAC) is difficult because of variations that occur in TAC across individuals, drinking episodes, and devices. We have developed mathematical models and the BrAC Estimator software for calibrating and inverting TAC into quantifiable BrAC estimates (eBrAC). The calibration protocol to determine the individualized parameters for a specific individual wearing a specific device requires a drinking session in which BrAC and TAC measurements are obtained simultaneously. This calibration protocol was originally conducted in the laboratory with breath analyzers used to produce the BrAC data. Here we develop and test an alternative calibration protocol using drinking diary data collected in the field with the smartphone app Intellidrink to produce the BrAC calibration data. We compared BrAC Estimator software results for 11 drinking episodes collected by an expert user when using Intellidrink versus breath analyzer measurements as BrAC calibration data. Inversion phase results indicated the Intellidrink calibration protocol produced similar eBrAC curves and captured peak eBrAC to within 0.0003%, time of peak eBrAC to within 18min, and area under the eBrAC curve to within 0.025% alcohol-hours as the breath analyzer calibration protocol. This study provides evidence that drinking diary data can be used in place of breath analyzer data in the BrAC Estimator software calibration procedure, which can reduce participant and researcher burden and expand the potential software user pool beyond researchers studying participants who can drink in the laboratory. Copyright © 2017. Published by Elsevier Ltd.

  1. Bioinformatics and Astrophysics Cluster (BinAc)

    NASA Astrophysics Data System (ADS)

    Krüger, Jens; Lutz, Volker; Bartusch, Felix; Dilling, Werner; Gorska, Anna; Schäfer, Christoph; Walter, Thomas

    2017-09-01

    BinAC provides central high performance computing capacities for bioinformaticians and astrophysicists from the state of Baden-Württemberg. The bwForCluster BinAC is part of the implementation concept for scientific computing for the universities in Baden-Württemberg. Community specific support is offered through the bwHPC-C5 project.

  2. 7 CFR 1737.31 - Area Coverage Survey (ACS).

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 11 2011-01-01 2011-01-01 false Area Coverage Survey (ACS). 1737.31 Section 1737.31... Studies-Area Coverage Survey and Loan Design § 1737.31 Area Coverage Survey (ACS). (a) The Area Coverage Survey (ACS) is a market forecast of service requirements of subscribers in a proposed service area. (b...

  3. 7 CFR 1737.31 - Area Coverage Survey (ACS).

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 11 2010-01-01 2010-01-01 false Area Coverage Survey (ACS). 1737.31 Section 1737.31... Studies-Area Coverage Survey and Loan Design § 1737.31 Area Coverage Survey (ACS). (a) The Area Coverage Survey (ACS) is a market forecast of service requirements of subscribers in a proposed service area. (b...

  4. 7 CFR 1737.31 - Area Coverage Survey (ACS).

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 11 2013-01-01 2013-01-01 false Area Coverage Survey (ACS). 1737.31 Section 1737.31... Studies-Area Coverage Survey and Loan Design § 1737.31 Area Coverage Survey (ACS). (a) The Area Coverage Survey (ACS) is a market forecast of service requirements of subscribers in a proposed service area. (b...

  5. 7 CFR 1737.31 - Area Coverage Survey (ACS).

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 11 2012-01-01 2012-01-01 false Area Coverage Survey (ACS). 1737.31 Section 1737.31... Studies-Area Coverage Survey and Loan Design § 1737.31 Area Coverage Survey (ACS). (a) The Area Coverage Survey (ACS) is a market forecast of service requirements of subscribers in a proposed service area. (b...

  6. 7 CFR 1737.31 - Area Coverage Survey (ACS).

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Studies-Area Coverage Survey and Loan Design § 1737.31 Area Coverage Survey (ACS). (a) The Area Coverage Survey (ACS) is a market forecast of service requirements of subscribers in a proposed service area. (b... 7 Agriculture 11 2014-01-01 2014-01-01 false Area Coverage Survey (ACS). 1737.31 Section 1737.31...

  7. 21 CFR 880.5500 - AC-powered patient lift.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false AC-powered patient lift. 880.5500 Section 880.5500... Devices § 880.5500 AC-powered patient lift. (a) Identification. An AC-powered lift is an electrically powered device either fixed or mobile, used to lift and transport patients in the horizontal or other...

  8. 21 CFR 880.5500 - AC-powered patient lift.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false AC-powered patient lift. 880.5500 Section 880.5500... Devices § 880.5500 AC-powered patient lift. (a) Identification. An AC-powered lift is an electrically powered device either fixed or mobile, used to lift and transport patients in the horizontal or other...

  9. AC-electric field dependent electroformation of giant lipid vesicles.

    PubMed

    Politano, Timothy J; Froude, Victoria E; Jing, Benxin; Zhu, Yingxi

    2010-08-01

    Giant vesicles of larger than 5 microm, which have been of intense interest for their potential as drug delivery vehicles and as a model system for cell membranes, can be rapidly formed from a spin-coated lipid thin film under an electric field. In this work, we explore the AC-field dependent electroformation of giant lipid vesicles in aqueous media over a wide range of AC-frequency from 1 Hz to 1 MHz and peak-to-peak field strength from 0.212 V/mm to 40 V/mm between two parallel conducting electrode surfaces. By using fluorescence microscopy, we perform in-situ microscopic observations of the structural evolution of giant vesicles formed from spin-coated lipid films under varied uniform AC-electric fields. The real-time observation of bilayer bulging from the lipid film, vesicle growth and fusing further examine the critical role of AC-induced electroosmotic flow of surrounding fluids for giant vesicle formation. A rich AC-frequency and field strength phase diagram is obtained experimentally to predict the AC-electroformation of giant unilamellar vesicles (GUVs) of l-alpha-phosphatidylcholine, where a weak dependence of vesicle size on AC-frequency is observed at low AC-field voltages, showing decreased vesicle size with a narrowed size distribution with increased AC-frequency. Formation of vesicles was shown to be constrained by an upper field strength of 10 V/mm and an upper AC-frequency of 10 kHz. Within these parameters, giant lipid vesicles were formed predominantly unilamellar and prevalent across the entire electrode surfaces. Copyright 2010 Elsevier B.V. All rights reserved.

  10. Lowering of the firing voltage and reducing of the discharge delay time in alternating current plasma display panels by a discontinuous spin-coated LaB{sub 6} film on the MgO protective layer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deng, Jiang, E-mail: dj78291@163.com; Zeng, Baoqing; Zhongshan Institute, University of Electronic Science and Technology of China, 528402 zhongshan

    2014-03-15

    A spin coated LaB{sub 6} discontinuous film is covered on MgO protective layer to improve the discharge performance of alternating current plasma display panels. Under the premise of high transmittance of more than 90%, a very small amount of polycrystal LaB{sub 6} powders added in an organic solvent are chosen as the coating solution. The discharge characteristics results show that with 250 torr 5% Xe-Ne pressure, the firing voltage and discharge delay time of the test panel with LaB{sub 6}/MgO double protective layer are decreased by 13.4% and 36.5%, respectively, compared with that of conventional MgO protective layer, likely owingmore » to the low work function of LaB{sub 6.} Furthermore, the aging time of the proposed structure is comparable to that of pure MgO protective layer. Therefore, it will not increase the production costs and is highly suitable to be applied for alternating current plasma display panels with low electrical power consumption.« less

  11. The AC-120: The advanced commercial transport

    NASA Technical Reports Server (NTRS)

    Duran, David; Griffin, Ernest; Mendoza, Saul; Nguyen, Son; Pickett, Tim; Noernberg, Clemm

    1993-01-01

    The main objective of this design was to fulfill a need for a new airplane to replace the aging 100 to 150 passenger, 1500 nautical mile range aircraft such as the Douglas DC9 and Boeing 737-100 airplanes. After researching the future aircraft market, conducting extensive trade studies, and analysis on different configurations, the AC-120 Advanced Commercial Transport final design was achieved. The AC-120's main design features include the incorporation of a three lifting surface configuration which is powered by two turboprop engines. The AC-120 is an economically sensitive aircraft which meets the new FM Stage Three noise requirements, and has lower NO(x) emissions than current turbofan powered airplanes. The AC-120 also improves on its contemporaries in passenger comfort, manufacturing, and operating cost.

  12. Cry1Ac production is costly for native plants attacked by non-Cry1Ac-targeted herbivores in the field.

    PubMed

    McGale, Erica; Diezel, Celia; Schuman, Meredith C; Baldwin, Ian T

    2018-05-13

    Plants are the primary producers in most terrestrial ecosystems and have complex defense systems to protect their produce. Defense-deficient, high-yielding agricultural monocultures attract abundant nonhuman consumers, but are alternatively defended through pesticide application and genetic engineering to produce insecticidal proteins such as Cry1Ac (Bacillus thuringiensis). These approaches alter the balance between yield protection and maximization but have been poorly contextualized to known yield-defense trade-offs in wild plants. The native plant Nicotiana attenuata was used to compare yield benefits of plants transformed to be defenseless to those with a full suite of naturally evolved defenses, or additionally transformed to ectopically produce Cry1Ac. An insecticide treatment allowed us to examine yield under different herbivore loads in N. attenuata's native habitat. Cry1Ac, herbivore damage, and growth parameters were monitored throughout the season. Biomass and reproductive correlates were measured at season end. Non-Cry1Ac-targeted herbivores dominated on noninsecticide-treated plants, and increased the yield drag of Cry1Ac-producing plants in comparison with endogenously defended or undefended plants. Insecticide-sprayed Cry1Ac-producing plants lagged less in stalk height, shoot biomass, and flower production. In direct comparison with the endogenous defenses of a native plant, Cry1Ac production did not provide yield benefits for plants under observed herbivore loads in a field study. © 2018 The Authors New Phytologist © 2018 New Phytologist Trust.

  13. ACS from development to operations

    NASA Astrophysics Data System (ADS)

    Caproni, Alessandro; Colomer, Pau; Jeram, Bogdan; Sommer, Heiko; Chiozzi, Gianluca; Mañas, Miguel M.

    2016-08-01

    The ALMA Common Software (ACS), provides the infrastructure of the distributed software system of ALMA and other projects. ACS, built on top of CORBA and Data Distribution Service (DDS) middleware, is based on a Component- Container paradigm and hides the complexity of the middleware allowing the developer to focus on domain specific issues. The transition of the ALMA observatory from construction to operations brings with it that ACS effort focuses primarily on scalability, stability and robustness rather than on new features. The transition came together with a shorter release cycle and a more extensive testing. For scalability, the most problematic area has been the CORBA notification service, used to implement the publisher subscriber pattern because of the asynchronous nature of the paradigm: a lot of effort has been spent to improve its stability and recovery from run time errors. The original bulk data mechanism, implemented using the CORBA Audio/Video Streaming Service, showed its limitations and has been replaced with a more performant and scalable DDS implementation. Operational needs showed soon the difference between releases cycles for Online software (i.e. used during observations) and Offline software, which requires much more frequent releases. This paper attempts to describe the impact the transition from construction to operations had on ACS, the solution adopted so far and a look into future evolution.

  14. Circular displays: control/display arrangements and stereotype strength with eight different display locations.

    PubMed

    Chan, Alan H S; Hoffmann, Errol R

    2015-01-01

    Two experiments are reported that were designed to investigate control/display arrangements having high stereotype strengths when using circular displays. Eight display locations relative to the operator and control were tested with rotational and translational controls situated on different planes according to the Frame of Reference Transformation Tool (FORT) model of Wickens et al. (2010). (Left. No, Right! Development of the Frame of Reference Transformation Tool (FORT), Proceedings of the Human Factors and Ergonomics Society 54th Annual Meeting, 54: 1022-1026). In many cases, there was little effect of display locations, indicating the importance of the Worringham and Beringer (1998. Directional stimulus-response compatibility: a test of three alternative principles. Ergonomics, 41(6), 864-880) Visual Field principle and an extension of this principle for rotary controls (Hoffmann and Chan (2013). The Worringham and Beringer 'visual field' principle for rotary controls. Ergonomics, 56(10), 1620-1624). The initial indicator position (12, 3, 6 and 9 o'clock) had a major effect on control/display stereotype strength for many of the six controls tested. Best display/control arrangements are listed for each of the different control types (rotational and translational) and for the planes on which they are mounted. Data have application where a circular display is used due to limited display panel space and applies to space-craft, robotics operators, hospital equipment and home appliances. Practitioner Summary: Circular displays are often used when there is limited space available on a control panel. Display/control arrangements having high stereotype strength are listed for four initial indicator positions. These arrangements are best for design purposes.

  15. Nonlinear plasma wave models in 3D fluid simulations of laser-plasma interaction

    NASA Astrophysics Data System (ADS)

    Chapman, Thomas; Berger, Richard; Arrighi, Bill; Langer, Steve; Banks, Jeffrey; Brunner, Stephan

    2017-10-01

    Simulations of laser-plasma interaction (LPI) in inertial confinement fusion (ICF) conditions require multi-mm spatial scales due to the typical laser beam size and durations of order 100 ps in order for numerical laser reflectivities to converge. To be computationally achievable, these scales necessitate a fluid-like treatment of light and plasma waves with a spatial grid size on the order of the light wave length. Plasma waves experience many nonlinear phenomena not naturally described by a fluid treatment, such as frequency shifts induced by trapping, a nonlinear (typically suppressed) Landau damping, and mode couplings leading to instabilities that can cause the plasma wave to decay rapidly. These processes affect the onset and saturation of stimulated Raman and Brillouin scattering, and are of direct interest to the modeling and prediction of deleterious LPI in ICF. It is not currently computationally feasible to simulate these Debye length-scale phenomena in 3D across experimental scales. Analytically-derived and/or numerically benchmarked models of processes occurring at scales finer than the fluid simulation grid offer a path forward. We demonstrate the impact of a range of kinetic processes on plasma reflectivity via models included in the LPI simulation code pF3D. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  16. ACS and STEMI treatment: gender-related issues.

    PubMed

    Chieffo, Alaide; Buchanan, Gill Louise; Mauri, Fina; Mehilli, Julinda; Vaquerizo, Beatriz; Moynagh, Anouska; Mehran, Roxana; Morice, Marie-Claude

    2012-08-01

    Cardiovascular disease is the leading cause of death amongst women, with acute coronary syndromes (ACS) representing a significant proportion. It has been reported that in women presenting with ACS there is underdiagnosis and consequent undertreatment leading to an increase in hospital and long-term mortality. Several factors have to be taken into account, including lack of awareness both at patient and at physician level. Women are generally not aware of the cardiovascular risk and symptoms, often atypical, and therefore wait longer to seek medical attention. In addition, physicians often underestimate the risk of ACS in women leading to a further delay in accurate diagnosis and timely appropriate treatment, including cardiac catheterisation and primary percutaneous coronary intervention, with consequent delayed revascularisation times. It has been acknowledged by the European Society of Cardiology that gender disparities do exist, with a Class I, Level of Evidence B recommendation that both genders should be treated in the same way when presenting with ACS. However, there is still a lack of awareness and the mission of Women in Innovation, in association with Stent for Life, is to change the perception of women with ACS and to achieve prompt diagnosis and treatment.

  17. Simulating the dynamics of complex plasmas.

    PubMed

    Schwabe, M; Graves, D B

    2013-08-01

    Complex plasmas are low-temperature plasmas that contain micrometer-size particles in addition to the neutral gas particles and the ions and electrons that make up the plasma. The microparticles interact strongly and display a wealth of collective effects. Here we report on linked numerical simulations that reproduce many of the experimental results of complex plasmas. We model a capacitively coupled plasma with a fluid code written for the commercial package comsol. The output of this model is used to calculate forces on microparticles. The microparticles are modeled using the molecular dynamics package lammps, which we extended to include the forces from the plasma. Using this method, we are able to reproduce void formation, the separation of particles of different sizes into layers, lane formation, vortex formation, and other effects.

  18. Electrostatic coalescence system with independent AC and DC hydrophilic electrodes

    DOEpatents

    Hovarongkura, A. David; Henry, Jr., Joseph D.

    1981-01-01

    An improved electrostatic coalescence system is provided in which independent AC and DC hydrophilic electrodes are employed to provide more complete dehydration of an oil emulsion. The AC field is produced between an AC electrode array and the water-oil interface wherein the AC electrode array is positioned parallel to the interface which acts as a grounded electrode. The emulsion is introduced into the AC field in an evenly distributed manner at the interface. The AC field promotes drop-drop and drop-interface coalescence of the water phase in the entering emulsion. The continuous oil phase passes upward through the perforated AC electrode array and enters a strong DC field produced between closely spaced DC electrodes in which small dispersed droplets of water entrained in the continuous phase are removed primarily by collection at hydrophilic DC electrodes. Large droplets of water collected by the electrodes migrate downward through the AC electrode array to the interface. All phase separation mechanisms are utilized to accomplish more complete phase separation.

  19. Use of an AC/DC/AC Electrochemical Technique to Assess the Durability of Protection Systems for Magnesium Alloys

    NASA Astrophysics Data System (ADS)

    Song, Sen; McCune, Robert C.; Shen, Weidian; Wang, Yar-Ming

    One task under the U.S. Automotive Materials Partnership (USAMP) "Magnesium Front End Research and Development" (MFERD) Project has been the evaluation of methodologies for the assessment of protective capability for a variety of proposed protection schemes for this hypothesized multi-material, articulated structure. Techniques which consider the entire protection system, including both pretreatments and topcoats are of interest. In recent years, an adaptation of the classical electrochemical impedance spectroscopy (EIS) approach using an intermediate cathodic DC polarization step (viz. AC/DC/AC) has been employed to accelerate breakdown of coating protection, specifically at the polymer-pretreatment interface. This work reports outcomes of studies to employ the AC/DC/AC approach for comparison of protective coatings to various magnesium alloys considered for front end structures. In at least one instance, the protective coating system breakdown could be attributed to the poorer intrinsic corrosion resistance of the sheet material (AZ31) relative to die-cast AM60B.

  20. Should fee-for-service be for all guideline-advocated acute coronary syndrome (ACS) care? Observations from the Snapshot ACS study.

    PubMed

    Briffa, Thomas G; Hammett, Christopher J; Cross, David B; Macisaac, Andrew I; Rankin, James M; Board, Neville; Carr, Bridie; Hyun, Karice K; French, John; Brieger, David B; Chew, Derek P

    2015-09-01

    The aim of the present study was to explore the association of health insurance status on the provision of guideline-advocated acute coronary syndrome (ACS) care in Australia. Consecutive hospitalisations of suspected ACS from 14 to 27 May 2012 enrolled in the Snapshot study of Australian and New Zealand patients were evaluated. Descriptive and logistic regression analysis was performed to evaluate the association of patient risk and insurance status with the receipt of care. In all, 3391 patients with suspected ACS from 247 hospitals (23 private) were enrolled in the present study. One-third of patients declared private insurance coverage; of these, 27.9% (304/1088) presented to private facilities. Compared with public patients, privately insured patients were more likely to undergo in-patient echocardiography and receive early angiography; furthermore, in those with a discharge diagnosis of ACS, there was a higher rate of revascularisation (P < 0.001). Each of these attracts potential fee-for-service. In contrast, proportionately fewer privately insured ACS patients were discharged on selected guideline therapies and were referred to a secondary prevention program (P = 0.056), neither of which directly attracts a fee. Typically, as GRACE (the Global Registry of Acute Coronary Events) risk score rose, so did the level of ACS care; however, propensity-adjusted analyses showed lower in-hospital adverse events among the insured group (odds ratio 0.68; 95% confidence interval 0.52-0.88; P = 0.004). Fee-for-service reimbursement may explain differences in the provision of selected guideline-advocated components of ACS care between privately insured and public patients.

  1. Visible camera imaging of plasmas in Proto-MPEX

    NASA Astrophysics Data System (ADS)

    Mosby, R.; Skeen, C.; Biewer, T. M.; Renfro, R.; Ray, H.; Shaw, G. C.

    2015-11-01

    The prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device being developed at Oak Ridge National Laboratory (ORNL). This machine plans to study plasma-material interaction (PMI) physics relevant to future fusion reactors. Measurements of plasma light emission will be made on Proto-MPEX using fast, visible framing cameras. The cameras utilize a global shutter, which allows a full frame image of the plasma to be captured and compared at multiple times during the plasma discharge. Typical exposure times are ~10-100 microseconds. The cameras are capable of capturing images at up to 18,000 frames per second (fps). However, the frame rate is strongly dependent on the size of the ``region of interest'' that is sampled. The maximum ROI corresponds to the full detector area, of ~1000x1000 pixels. The cameras have an internal gain, which controls the sensitivity of the 10-bit detector. The detector includes a Bayer filter, for ``true-color'' imaging of the plasma emission. This presentation will exmine the optimized camera settings for use on Proto-MPEX. This work was supported by the US. D.O.E. contract DE-AC05-00OR22725.

  2. Cadmium-induced ethylene production and responses in Arabidopsis thaliana rely on ACS2 and ACS6 gene expression

    PubMed Central

    2014-01-01

    Background Anthropogenic activities cause metal pollution worldwide. Plants can absorb and accumulate these metals through their root system, inducing stress as a result of excess metal concentrations inside the plant. Ethylene is a regulator of multiple plant processes, and is affected by many biotic and abiotic stresses. Increased ethylene levels have been observed after exposure to excess metals but it remains unclear how the increased ethylene levels are achieved at the molecular level. In this study, the effects of cadmium (Cd) exposure on the production of ethylene and its precursor 1-aminocyclopropane-1-carboxylic acid (ACC), and on the expression of the ACC Synthase (ACS) and ACC Oxidase (ACO) multigene families were investigated in Arabidopsis thaliana. Results Increased ethylene release after Cd exposure was directly measurable in a system using rockwool-cultivated plants; enhanced levels of the ethylene precursor ACC together with higher mRNA levels of ethylene responsive genes: ACO2, ETR2 and ERF1 also indicated increased ethylene production in hydroponic culture. Regarding underlying mechanisms, it was found that the transcript levels of ACO2 and ACO4, the most abundantly expressed members of the ACO multigene family, were increased upon Cd exposure. ACC synthesis is the rate-limiting step in ethylene biosynthesis, and transcript levels of both ACS2 and ACS6 showed the highest increase and became the most abundant isoforms after Cd exposure, suggesting their importance in the Cd-induced increase of ethylene production. Conclusions Cadmium induced the biosynthesis of ACC and ethylene in Arabidopsis thaliana plants mainly via the increased expression of ACS2 and ACS6. This was confirmed in the acs2-1acs6-1 double knockout mutants, which showed a decreased ethylene production, positively affecting leaf biomass and resulting in a delayed induction of ethylene responsive gene expressions without significant differences in Cd contents between wild-type and

  3. Modelling ac ripple currents in HTS coated conductors

    NASA Astrophysics Data System (ADS)

    Xu, Zhihan; Grilli, Francesco

    2015-10-01

    Dc transmission using high temperature superconducting (HTS) coated conductors (CCs) offers a promising solution to the globally growing demand for effective, reliable and economic transmission of green energy up to the gigawatt level over very long distances. The credible estimation of the losses and thereby the heat dissipation involved, where ac ripples (introduced in rectification/ac-dc conversion) are viewed as a potential source of notable contribution, is highly essential for the rational design of practical HTS dc transmission cables and corresponding cryogenic systems to fulfil this demand. Here we report a targeted modelling study into the ac losses in a HTS CC subject to dc and ac ripple currents simultaneously, by solving Maxwell’s equations using the finite element method (FEM) in the commercial software package COMSOL. It is observed that the instantaneous loss exhibits only one peak per cycle in the HTS CC subject to sinusoidal ripples, given that the amplitude of the ac ripples is smaller than approximately 20% of that of the dc current. This is a distinct contrast to the usual observation of two peaks per cycle in a HTS CC subject to ac currents only. The unique mechanism is also revealed, which is directly associated with the finding that, around any local minima of the applied ac ripples, the critical state of -J c is never reached at the edges of the HTS CC, as it should be according to the Bean model. When running further into the longer term, it is discovered that the ac ripple loss of the HTS CC in full-wave rectification decays monotonically, at a speed which is found to be insensitive to the frequency of the applied ripples within our targeted situations, to a relatively low level of approximately 1.38 × 10-4 W m-1 in around 1.7 s. Comparison between this level and other typical loss contributions in a HTS dc cable implies that ac ripple currents in HTS CCs should only be considered as a minor source of dissipation in superconducting dc

  4. Numerical study of nonequilibrium plasma assisted detonation initiation in detonation tube

    NASA Astrophysics Data System (ADS)

    Zhou, Siyin; Wang, Fang; Che, Xueke; Nie, Wansheng

    2016-12-01

    Nonequilibrium plasma has shown great merits in ignition and combustion nowadays, which should be especially useful for hypersonic propulsion. A coaxial electrodes configuration was established to investigate the effect of alternating current (AC) dielectric barrier discharge nonequilibrium plasma on the detonation initiation process in a hydrogen-oxygen mixture. A discharge simulation-combustion simulation loosely coupled method was used to simulate plasma assisted detonation initiation. First, the dielectric barrier discharge in the hydrogen-oxygen mixture driven by an AC voltage was simulated, which takes 17 kinds of particles (including positively charged particles, negatively charged particles, and neutral particles) and 47 reactions into account. The temporal and spatial characteristics of the discharge products were obtained. Then, the discharge products were incorporated into the combustion model of a detonation combustor as the initial conditions for the later detonation initiation simulation. Results showed that the number density distributions of plasma species are different in space and time, and develop highly nonuniformly from high voltage electrode to grounded electrode at certain times. All the active species reach their highest concentration at approximately 0.6T (T denotes a discharge cycle). Compared with the no plasma case, the differences of flowfield shape mainly appear in the early stage of the deflagration to detonation transition process. None of the sub-processes (including the very slow combustion, deflagration, over-driven detonation, detonation decay, and propagation of a self-sustained stable detonation wave) have been removed by the plasma. After the formation of a C-J detonation wave, the whole flowfield remains unchanged. With the help of plasma, the deflagration to detonation transition (DDT) time and distance are reduced by about 11.6% and 12.9%, respectively, which should be attributed to the active particles effect of

  5. ACS Data Handbook v.6.0

    NASA Astrophysics Data System (ADS)

    Gonzaga, S.; et al.

    2011-03-01

    ACS was designed to provide a deep, wide-field survey capability from the visible to near-IR using the Wide Field Camera (WFC), high resolution imaging from the near-UV to near-IR with the now-defunct High Resolution Camera (HRC), and solar-blind far-UV imaging using the Solar Blind Camera (SBC). The discovery efficiency of ACS's Wide Field Channel (i.e., the product of WFC's field of view and throughput) is 10 times greater than that of WFPC2. The failure of ACS's CCD electronics in January 2007 brought a temporary halt to CCD imaging until Servicing Mission 4 in May 2009, when WFC functionality was restored. Unfortunately, the high-resolution optical imaging capability of HRC was not recovered.

  6. Determination of some enzymes and macro- and microelements in stallion seminal plasma and their correlations to semen quality.

    PubMed

    Pesch, Sandra; Bergmann, Martin; Bostedt, Hartwig

    2006-07-15

    Seminal plasma is very important for sperm metabolism as well as sperm function and survival and transport in the female genital tract. Analysis of enzyme activities and concentrations of elements can estimate integrity and function of sperm cell membranes. In man much data are available about biochemical analyses of seminal plasma. However, not many studies have been conducted in horses yet. We collected ejaculates from 72 stallions, measured the volume, obtained seminal plasma by centrifugation and examined spermatozoa with light microscopy for motility, concentration, for dead sperm and morphology. Of seminal plasma fluid, we measured activities of aspartate-amino-transferase (AST), gamma-glutamyl-transferase (GGT), alkaline phosphatase (AlP), acid phosphatase (AcP) and lactate-dehydrogenase (LDH) as well as concentrations of sodium (Na(+)), potassium (K(+)), total and ionised calcium (Ca(TOTAL)/Ca(2+)), magnesium (Mg(2+)), phosphate (P), chloride (Cl), copper (Cu), iron (Fe) and zinc (Zn). In addition, correlations among different parameters in light microscopy and seminal plasma were statistically examined by using the Spearman rank correlation coefficient. Median enzyme activities for AST, GGT, AlP, AcP and LDH were 80.0, 7,500, 30,200, 20.0, 81.0 IU/L, respectively. Concentrations of Na(+), K(+), Ca(TOTAL), Ca(2+), Mg(2+), P, Cl were 110.5, 22.1, 2.9, 1.7, 3.1, 1.1 and 114.5 mmol/L, and of microelements Cu, Fe and Zn were 17.8, 1.9 and 13.2 micromol/L, respectively. Furthermore, we found significant correlations between semen volume as well as sperm concentration and AST, GGT, AlP, AcP and LDH as well as Fe and Zn. This made us propose a primary testicular and epididymal origin of these parameters. Significant correlation between GGT and motility may be a sign for its function for cell protection against free radicals. LDH activity significantly correlates with motility and progressive motility, live:dead-ratio and pathomorphology. In our study, LDH seems to

  7. A rapid and fluorogenic TMP-AcBOPDIPY probe for covalent labeling of proteins in live cells.

    PubMed

    Liu, Wei; Li, Fu; Chen, Xi; Hou, Jian; Yi, Long; Wu, Yao-Wen

    2014-03-26

    Protein labeling is enormously useful for characterizing protein function in cells and organisms. Chemical tagging methods have emerged as a new generation protein labeling strategy in live cells. Here we have developed a novel and versatile TMP-AcBOPDIPY probe for selective and turn-on labeling of proteins in live cells. A small monomeric tag, E. coli dihydrofolate reductase (eDHFR), was rationally designed to introduce a cysteine in the vicinity of the ligand binding site. Trimethoprim (TMP) that specifically binds to eDHFR was linked to the BOPDIPY fluorophore containing a mildly thiol-reactive acrylamide group. TMP-AcBOPDIPY rapidly labeled engineered eDHFR tags via a reaction termed affinity conjugation (a half-life of ca. 2 min), which is one of the top fast chemical probes for protein labeling. The probe displays 2-fold fluorescence enhancement upon labeling of proteins. We showed that the probe specifically labeled intracellular proteins in live cells without and with washing out the dye. We demonstrated its utility in visualizing intracellular processes by fluorescence-lifetime imaging microscopy (FLIM) measurements.

  8. Plasma Discharge with Different Electrode Diameters for Reducing Methylene Blue Concentration

    NASA Astrophysics Data System (ADS)

    Rasyidah, H.; Kusumandari; Saraswati, T. E.; Anwar, M.

    2018-03-01

    Recently, plasma technology has gained attention since it overcomes the shortcomings of water treatment. This research studies the effect of electrode diameter of plasma discharge reactors on the concentration reduction of methylene blue as an organic solution. The plasma discharge reactor was built from a pair of stainless needle electrodes connected with high-AC voltage. The electrodes were placed approximately 2 mm above the solution and stirred at 5.5 rpm. The diameters of the electrodes were 2, 3.2 and 4 mm. The times for plasma treatment were set at 2, 4, 6, 8 and 10 min. Absorbance, temperature and pH of the solution were measured to know the effects of electrode diameter of the plasma reactor. Absorbance and pH significantly decreased after plasma treatment. The best of the absorbance reduction were obtained when the sample was treated under plasma discharge using the smallest diameter electrodes for 8-10 min.

  9. ACS-Hach Programs: Supporting Excellence in High School Chemistry Teaching

    NASA Astrophysics Data System (ADS)

    Taylor, Terri

    2009-05-01

    In January 2009, the ACS received a gift of approximately $33 million from the Hach Scientific Foundation, the largest gift in the society's 133-year history. The foundation's programs will be continued by the ACS and will complement pre-existing ACS resources that support high school chemistry teaching. Three activities serve as the pillars of the ACS-Hach programs—the High School Chemistry Grant Program, the Second Career Teacher Scholarship Program, and the Land Grant University Scholars Program. Collectively, the ACS-Hach programs support high school chemistry teaching and learning by responding to the needs of both in-service and pre-service secondary teachers. The goals of each of the ACS-Hach programs align well with the ACS Mission—to advance the broader chemistry enterprise and its practitioners for the benefit of Earth and its people.

  10. ACS Presents Science Education Report to Congress.

    ERIC Educational Resources Information Center

    Krieger, James

    1989-01-01

    Discusses an American Chemical Society (ACS)'s report on science education which is a synthesis of a series of policies developed by ACS. Summarizes recommendations in four areas: elementary teacher education; pre-high school curricula; university research funding; and underrepresented populations. (YP)

  11. A dry-cooled AC quantum voltmeter

    NASA Astrophysics Data System (ADS)

    Schubert, M.; Starkloff, M.; Peiselt, K.; Anders, S.; Knipper, R.; Lee, J.; Behr, R.; Palafox, L.; Böck, A. C.; Schaidhammer, L.; Fleischmann, P. M.; Meyer, H.-G.

    2016-10-01

    The paper describes a dry-cooled AC quantum voltmeter system operated up to kilohertz frequencies and 7 V rms. A 10 V programmable Josephson voltage standard (PJVS) array was installed on a pulse tube cooler (PTC) driven with a 4 kW air-cooled compressor. The operating margins at 70 GHz frequencies were investigated in detail and found to exceed 1 mA Shapiro step width. A key factor for the successful chip operation was the low on-chip power consumption of 65 mW in total. A thermal interface between PJVS chip and PTC cold stage was used to avoid a significant chip overheating. By installing the cryocooled PJVS array into an AC quantum voltmeter setup, several calibration measurements of dc standards and calibrator ac voltages up to 2 kHz frequencies were carried out to demonstrate the full functionality. The results are discussed and compared to systems with standard liquid helium cooling. For dc voltages, a direct comparison measurement between the dry-cooled AC quantum voltmeter and a liquid-helium based 10 V PJVS shows an agreement better than 1 part in 1010.

  12. The effect of display movement angle, indicator type and display location on control/display stereotype strength.

    PubMed

    Hoffmann, Errol R; Chan, Alan H S

    2017-08-01

    Much research on stereotype strength relating display and control movements for displays moving in the vertical or horizontal directions has been reported. Here we report effects of display movement angle, where the display moves at angles (relative to the vertical) of between 0° and 180°. The experiment used six different controls, four display locations relative to the operator and three types of indicator. Indicator types were included because of the strong effects of the 'scale-side principle' that are variable with display angle. A directional indicator had higher stereotype strength than a neutral indicator, and showed an apparent reversal in control/display stereotype direction beyond an angle of 90°. However, with a neutral indicator this control reversal was not present. Practitioner Summary: The effects of display moving at angles other than the four cardinal directions, types of control, location of display and types of indicator are investigated. Indicator types (directional and neutral) have an effect on stereotype strength and may cause an apparent control reversal with change of display movement angle.

  13. From Beamline to Scanner with 225Ac

    NASA Astrophysics Data System (ADS)

    Robertson, Andrew K. H.; Ramogida, Caterina F.; Kunz, Peter; Rodriguez-Rodriguez, Cristina; Schaffer, Paul; Sossi, Vesna

    2016-09-01

    Due to the high linear energy transfer and short range of alpha-radiation, targeted radiation therapy using alpha-emitting pharmaceuticals that successfully target small disease clusters will kill target cells with limited harm to healthy tissue, potentially treating the most aggressive forms of cancer. As the parent of a decay chain with four alpha- and two beta-decays, 225Ac is a promising candidate for such a treatment. However, this requires retention of the entire decay chain at the target site, preventing the creation of freely circulating alpha-emitters that reduce therapeutic effect and increase toxicity to non-target tissues. Two major challenges to 225Ac pharmaceutical development exist: insufficient global supply, and the difficulty of preventing toxicity by retaining the entire decay chain at the target site. While TRIUMF works towards large-scale (C i amounts) production of 225Ac, we already use our Isotope Separation On-Line facility to provide small (< 1 mCi) quantities for in-house chemistry and imaging research that aims to improve and assess 225Ac radiopharmaceutical targeting. This presentation provides an overview of this research program and the journey of 225Ac from the beamline to the scanner. This research is funded by the Natural Sciences and Engineering Research Council of Canada.

  14. Power Balance Analysis of the Prototype-Material Plasma Exposure eXperiment

    NASA Astrophysics Data System (ADS)

    Showers, M. A.; Biewer, T. M.; Caneses, J. F.; Caughman, J. B. O.; Lumsdaine, A.; Owen, L.; Rapp, J.; Youchison, D.; Beers, C. J.; Donovan, D. C.; Kafle, N.; Ray, H. B.

    2017-10-01

    The Prototype-Material Plasma Exposure eXperiment (Proto-MPEX) is a test bed for the plasma source concept for the planned Material Plasma Exposure eXperiment (MPEX), a steady-state linear device studying plasma material interactions for fusion reactors. A power balance of Proto-MPEX attempts to identify machine operating parameters that will improve Proto-MPEX's performance, potentially impacting the MPEX design concept. A power balance has been performed utilizing an extensive diagnostic suite to identify mechanisms and locations of power loss from the main plasma. The diagnostic package includes infrared cameras, double Langmuir probes, fluoroptic probes, Mach probes, a Thomson scattering diagnostic, a McPherson spectrometer and in-vessel thermocouples. Radiation losses are estimated with absolute calibrated spectroscopic signals. This work was supported by the U.S. D.O.E. contract DE-AC05-00OR22725.

  15. 21 CFR 880.5100 - AC-powered adjustable hospital bed.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false AC-powered adjustable hospital bed. 880.5100... (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Therapeutic Devices § 880.5100 AC-powered adjustable hospital bed. (a) Identification. An AC-powered...

  16. 21 CFR 880.5100 - AC-powered adjustable hospital bed.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false AC-powered adjustable hospital bed. 880.5100... (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Therapeutic Devices § 880.5100 AC-powered adjustable hospital bed. (a) Identification. An AC-powered...

  17. 21 CFR 880.5100 - AC-powered adjustable hospital bed.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false AC-powered adjustable hospital bed. 880.5100... (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Therapeutic Devices § 880.5100 AC-powered adjustable hospital bed. (a) Identification. An AC-powered...

  18. 21 CFR 880.5100 - AC-powered adjustable hospital bed.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false AC-powered adjustable hospital bed. 880.5100... (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Therapeutic Devices § 880.5100 AC-powered adjustable hospital bed. (a) Identification. An AC-powered...

  19. Plasma-Facing Component and Materials Testing for the NSTX-U

    NASA Astrophysics Data System (ADS)

    Jaworski, Michael; Brooks, A.; Gerhardt, S.; Loesser, D.; Mardenfeld, M.; Menard, J.; Gray, T.; Reinke, M.

    2017-10-01

    The NSTX-U Recovery Project is developing plasma-facing components for use in the divertor of NSTX-U. The extreme conditions of the NSTX-U divertor make it possible to stress even graphite surfaces to the material limits leading to the possibility of component failures. In addition, the complex, mixed-material environment of the NSTX-U due to the use of boron and lithium wall conditioning techniques creates significant uncertainties in the monitoring of the PFCs. A testing program has been developed to inform on the material and design limitations of the NSTX-U high-heat flux components. These tests include high-heat flux testing in electron beam facilities as well as plasma-based testing. The NSTX-U components could experience perpendicular heat fluxes as high as 45 MW/m2. Parallel heat fluxes onto leading edges could reach 475 MW/m2. The testing program and material survey plan will be presented. Work supported by DOE contract DE-AC02-09CH11466 and DE-AC05-00OR22725.

  20. A Case Study of Wind-PV-Thermal-Bundled AC/DC Power Transmission from a Weak AC Network

    NASA Astrophysics Data System (ADS)

    Xiao, H. W.; Du, W. J.; Wang, H. F.; Song, Y. T.; Wang, Q.; Ding, J.; Chen, D. Z.; Wei, W.

    2017-05-01

    Wind power generation and photovoltaic (PV) power generation bundled with the support by conventional thermal generation enables the generation controllable and more suitable for being sent over to remote load centre which are beneficial for the stability of weak sending end systems. Meanwhile, HVDC for long-distance power transmission is of many significant technique advantages. Hence the effects of wind-PV-thermal-bundled power transmission by AC/DC on power system have become an actively pursued research subject recently. Firstly, this paper introduces the technical merits and difficulties of wind-photovoltaic-thermal bundled power transmission by AC/DC systems in terms of meeting the requirement of large-scale renewable power transmission. Secondly, a system model which contains a weak wind-PV-thermal-bundled sending end system and a receiving end system in together with a parallel AC/DC interconnection transmission system is established. Finally, the significant impacts of several factors which includes the power transmission ratio between the DC and AC line, the distance between the sending end system and receiving end system, the penetration rate of wind power and the sending end system structure on system stability are studied.

  1. 1000 X Difference Between Current Displays and Capability of Human Visual System: Payoff Potential for Affordable Defense Systems

    DTIC Science & Technology

    2000-01-01

    second tier technologies: digital micromirror devices (DMD); alternating current gas plasma (ACGP); inorganic electroluminescent (EL, TFEL, AMEL... Micromirror Device (DMD) - Alternating Current Gas Plasma (ACGP) - Electroluminescent (EL, TFEL, AMEL) - Vacuum Fluorescent Display (VFD) - Inorganic Light...Instruments Digital Micromirror Device (DMD) Digital Light Processing technology and another, the Qualcomm/Hughes-JVC CRT/Liquid Crystal Light Valve

  2. Feed intake is related to changes in plasma nonesterified fatty acid concentration and hepatic acetyl CoA content following feeding in lactating dairy cows.

    PubMed

    Piantoni, P; Ylioja, C M; Allen, M S

    2015-10-01

    The relationship between hepatic acetyl CoA (AcCoA) content and dry matter intake (DMI) was evaluated using 28 multiparous Holstein cows; 14 were early postpartum (PP; 12.6 ± 3.8 d in milk) and 14 were late-lactation cows (LL; 269 ± 30 d in milk). Cows were fed once daily, and DMI was determined for the first 4h after feeding. Liver and blood samples were collected before feeding and 4h after feeding. Feed intake over the 4-h period ranged from 3.7 to 9.6 kg of dry matter and was similar for the 2 stages of lactation. Before feeding, hepatic AcCoA content was greater for PP compared with LL cows (34.4 vs. 12.5 nmol/g), and decreased over the 4h after feeding for PP only (28.7 vs. 34.4 nmol/g). The range for change in AcCoA over the 4-h period was wide for both PP (-24.3 to 10.4 nmol/g) and LL (-5.7 to 16.1 nmol/g), and was related negatively to DMI at 4h for both PP (R(2) = 0.55) and LL (R(2) = 0.31). The reduction in plasma NEFA concentration over the 4-h period was greater for PP than LL cows (-681 vs. -47 µEq/L), and was related to DMI at 4h for both PP and LL (both R(2) = 0.38). Greater DMI among cows over the first 4h after feeding might have been from a sharper reduction in supply of AcCoA in the liver for oxidation during meals because of the reduction in plasma NEFA concentration. Consistent with this is that the change in AcCoA was positively related to the reduction in plasma NEFA concentration for PP cows (R(2) = 0.31). However, change in plasma NEFA concentration was not related to change in hepatic AcCoA in LL cows, indicating that the pool of AcCoA in LL cows is not as dependent on NEFA flux to the liver as that of PP cows. Further research is required to determine production and fate of AcCoA within the timeframe of meals and the effects of feeding on energy charge in hepatic tissue. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. 21 CFR 888.1240 - AC-powered dynamometer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false AC-powered dynamometer. 888.1240 Section 888.1240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1240 AC-powered dynamometer. (a...

  4. 21 CFR 888.1240 - AC-powered dynamometer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false AC-powered dynamometer. 888.1240 Section 888.1240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1240 AC-powered dynamometer. (a...

  5. 21 CFR 888.1240 - AC-powered dynamometer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false AC-powered dynamometer. 888.1240 Section 888.1240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1240 AC-powered dynamometer. (a...

  6. Atmospheric Pressure Plasma Induced Sterilization and Chemical Neutralization

    NASA Astrophysics Data System (ADS)

    Garate, Eusebio; Evans, Kirk; Gornostaeva, Olga; Alexeff, Igor; Lock Kang, Weng; Wood, Thomas K.

    1998-11-01

    We are studying chemical neutralization and surface decontamination using atmospheric pressure plasma discharges. The plasma is produced by corona discharge from an array of pins and a ground plane. The array is constructed so that various gases, like argon or helium, can be flowed past the pins where the discharge is initiated. The pin array can be biased using either DC, AC or pulsed discharges. Results indicate that the atmospheric plasma is effective in sterilizing surfaces with biological contaminants like E-coli and bacillus subtilus cells. Exposure times of less than four minutes in an air plasma result in a decrease in live colony counts by six orders of magnitude. Greater exposure times result in a decrease of live colony counts of up to ten orders of magnitude. The atmospheric pressure discharge is also effective in decomposing organic phosphate compounds that are simulants for chemical warfare agents. Details of the decomposition chemistry, by-product formation, and electrical energy consumption of the system will be discussed.

  7. 21 CFR 880.5100 - AC-powered adjustable hospital bed.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false AC-powered adjustable hospital bed. 880.5100 Section 880.5100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Therapeutic Devices § 880.5100 AC-powered adjustable hospital bed. (a) Identification. An AC-powered...

  8. Nonlinear AC susceptibility, surface and bulk shielding

    NASA Astrophysics Data System (ADS)

    van der Beek, C. J.; Indenbom, M. V.; D'Anna, G.; Benoit, W.

    1996-02-01

    We calculate the nonlinear AC response of a thin superconducting strip in perpendicular field, shielded by an edge current due to the geometrical barrier. A comparison with the results for infinite samples in parallel field, screened by a surface barrier, and with those for screening by a bulk current in the critical state, shows that the AC response due to a barrier has general features that are independent of geometry, and that are significantly different from those for screening by a bulk current in the critical state. By consequence, the nonlinear (global) AC susceptibility can be used to determine the origin of magnetic irreversibility. A comparison with experiments on a Bi 2Sr 2CaCu 2O 8+δ crystal shows that in this material, the low-frequency AC screening at high temperature is mainly due to the screening by an edge current, and that this is the unique source of the nonlinear magnetic response at temperatures above 40 K.

  9. AC BREAKDOWN IN GASES

    DTIC Science & Technology

    electron- emission (multipactor) region, and (3) the low-frequency region. The breakdown mechanism in each of these regions is explained. An extensive bibliography on AC breakdown in gases is included.

  10. Thalassiolins A-C: new marine-derived inhibitors of HIV cDNA integrase.

    PubMed

    Rowley, David C; Hansen, Mark S T; Rhodes, Denise; Sotriffer, Christoph A; Ni, Haihong; McCammon, J Andrew; Bushman, Frederic D; Fenical, William

    2002-11-01

    Human immunodeficiency virus (HIV) replication requires integration of viral cDNA into the host genome, a process mediated by the viral enzyme integrase. We describe a new series of HIV integrase inhibitors, thalassiolins A-C (1-3), isolated from the Caribbean sea grass Thalassia testudinum. The thalassiolins are distinguished from other flavones previously studied by the substitution of a sulfated beta-D-glucose at the 7-position, a substituent that imparts increased potency against integrase in biochemical assays. The most active of these molecules, thalassiolin A (1), displays in vitro inhibition of the integrase catalyzed strand transfer reaction (IC50=0.4 microM) and an antiviral IC50 of 30 microM. Molecular modeling studies indicate a favorable binding mode is probable at the catalytic core domain of HIV-1 integrase.

  11. Assessing the allelotypic effect of two aminocyclopropane carboxylic acid synthase-encoding genes MdACS1 and MdACS3a on fruit ethylene production and softening in Malus

    PubMed Central

    Dougherty, Laura; Zhu, Yuandi; Xu, Kenong

    2016-01-01

    Phytohormone ethylene largely determines apple fruit shelf life and storability. Previous studies demonstrated that MdACS1 and MdACS3a, which encode 1-aminocyclopropane-1-carboxylic acid synthases (ACS), are crucial in apple fruit ethylene production. MdACS1 is well-known to be intimately involved in the climacteric ethylene burst in fruit ripening, while MdACS3a has been regarded a main regulator for ethylene production transition from system 1 (during fruit development) to system 2 (during fruit ripening). However, MdACS3a was also shown to have limited roles in initiating the ripening process lately. To better assess their roles, fruit ethylene production and softening were evaluated at five time points during a 20-day post-harvest period in 97 Malus accessions and in 34 progeny from 2 controlled crosses. Allelotyping was accomplished using an existing marker (ACS1) for MdACS1 and two markers (CAPS866 and CAPS870) developed here to specifically detect the two null alleles (ACS3a-G289V and Mdacs3a) of MdACS3a. In total, 952 Malus accessions were allelotyped with the three markers. The major findings included: The effect of MdACS1 was significant on fruit ethylene production and softening while that of MdACS3a was less detectable; allele MdACS1–2 was significantly associated with low ethylene and slow softening; under the same background of the MdACS1 allelotypes, null allele Mdacs3a (not ACS3a-G289V) could confer a significant delay of ethylene peak; alleles MdACS1–2 and Mdacs3a (excluding ACS3a-G289V) were highly enriched in M. domestica and M. hybrid when compared with those in M. sieversii. These findings are of practical implications in developing apples of low and delayed ethylene profiles by utilizing the beneficial alleles MdACS1-2 and Mdacs3a. PMID:27231553

  12. Modelling and Display of the Ultraviolet Sky

    NASA Astrophysics Data System (ADS)

    Daniels, J.; Henry, R.; Murthy, J.; Allen, M.; McGlynn, T. A.; Scollick, K.

    1994-12-01

    A computer program is currently under development to model in 3D - one dimension of which is wavelength - all the known and major speculated sources of ultraviolet (900 A - 3100 A ) radiation over the celestial sphere. The software is being written in Fortran 77 and IDL and currently operates under IRIX (the operating system of the Silicon Graphics Iris Machine); all output models are in FITS format. Models along with display software will become available to the astronomical community. The Ultraviolet Sky Model currently includes the Zodiacal Light, Point Sources of Emission, and the Diffuse Galactic Light. The Ultraviolet Sky Model is currently displayed using SkyView: a package under development at NASA/ GSFC, which allows users to retrieve and display publically available all-sky astronomical survey data (covering many wavebands) over the Internet. We present a demonstration of the SkyView display of the Ultraviolet Model. The modelling is a five year development project: the work illustrated here represents product output at the end of year one. Future work includes enhancements to the current models and incorporation of the following models: Galactic Molecular Hydrogen Fluorescence; Galactic Highly Ionized Atomic Line Emission; Integrated Extragalactic Light; and speculated sources in the intergalactic medium such as Ionized Plasma and radiation from Non-Baryonic Particle Decay. We also present a poster which summarizes the components of the Ultraviolet Sky Model and outlines a further package that will be used to display the Ultraviolet Model. This work is supported by United States Air Force Contract F19628-93-K-0004. Dr J. Daniels is supported with a post-doctoral Fellowship from the Leverhulme Foundation, London, United Kingdom. We are also grateful for the encouragement of Dr Stephen Price (Phillips Laboratory, Hanscomb Air Force Base, MA)

  13. Acylcarnitine Profiles in Plasma and Tissues of Hyperglycemic NZO Mice Correlate with Metabolite Changes of Human Diabetes

    PubMed Central

    Daniel, Hannelore

    2018-01-01

    The New Zealand obese (NZO) mouse is a polygenic model for obesity and diabetes with obese females and obese, diabetes-prone males, used to study traits of the metabolic syndrome like type 2 diabetes mellitus (T2DM), obesity, and dyslipidaemia. By using LC-MS/MS, we here examine the suitability of this model to mirror tissue-specific changes in acylcarnitine (AC) and amino acid (AA) species preceding T2DM which may reflect patterns investigated in human metabolism. We observed high concentrations of fatty acid-derived ACs in 11 female mice, high abundance of branched-chain amino acid- (BCAA-) derived ACs in 6 male mice, and slight increases in BCAA-derived ACs in the remaining 6 males. Principal component analysis (PCA) including all ACs and AAs confirmed our hypothesis especially in plasma samples by clustering females, males with high BCAA-derived ACs, and males with slight increases in BCAA-derived ACs. Concentrations of insulin, blood glucose, NEFAs, and triacylglycerols (TAGs) further supported the hypothesis of high BCAA-derived ACs being able to mirror the onset of diabetic traits in male individuals. In conclusion, alterations in AC and AA profiles overlap with observations from human studies indicating the suitability of NZO mice to study metabolic changes preceding human T2DM. PMID:29854816

  14. Isolation and characterization of pediocin AcH chimeric protein mutants with altered bactericidal activity.

    PubMed

    Miller, K W; Schamber, R; Osmanagaoglu, O; Ray, B

    1998-06-01

    A collection of pediocin AcH amino acid substitution mutants was generated by PCR random mutagenesis of DNA encoding the bacteriocin. Mutants were isolated by cloning mutagenized DNA into an Escherichia coli malE plasmid that directs the secretion of maltose binding protein-pediocin AcH chimeric proteins and by screening transformant colonies for bactericidal activity against Lactobacillus plantarum NCDO955 (K. W. Miller, R. Schamber, Y. Chen, and B. Ray, 1998. Appl. Environ. Microbiol. 64:14-20, 1998). In all, 17 substitution mutants were isolated at 14 of the 44 amino acids of pediocin AcH. Seven mutants (N5K, C9R, C14S, C14Y, G37E, G37R, and C44W) were completely inactive against the pediocin AcH-sensitive strains L. plantarum NCDO955, Listeria innocua Lin11, Enterococcus faecalis M1, Pediococcus acidilactici LB42, and Leuconostoc mesenteroides Ly. A C24S substitution mutant constructed by other means also was inactive against these bacteria. Nine other mutants (K1N, W18R, I26T, M31T, A34D, N41K, H42L, K43N, and K43E) retained from <1% to approximately 60% of wild-type activity when assayed against L. innocua Lin11. One mutant, K11E, displayed approximately 2. 8-fold-higher activity against this indicator. About one half of the mutations mapped to amino acids that are conserved in the pediocin-like family of bacteriocins. All four cysteines were found to be required for activity, although only C9 and C14 are conserved among pediocin-like bacteriocins. Several basic amino acids as well as nonpolar amino acids located within the hydrophobic C-terminal region also were found to be important. The mutations are discussed in the context of structural models that have been proposed for the bacteriocin.

  15. Successful enrichment of the ubiquitous freshwater acI Actinobacteria.

    PubMed

    Garcia, Sarahi L; McMahon, Katherine D; Grossart, Hans-Peter; Warnecke, Falk

    2014-02-01

    Actinobacteria of the acI lineage are often the numerically dominant bacterial phylum in surface freshwaters, where they can account for > 50% of total bacteria. Despite their abundance, there are no described isolates. In an effort to obtain enrichment of these ubiquitous freshwater Actinobacteria, diluted freshwater samples from Lake Grosse Fuchskuhle, Germany, were incubated in 96-well culture plates. With this method, a successful enrichment containing high abundances of a member of the lineage acI was established. Phylogenetic classification showed that the acI Actinobacteria of the enrichment belonged to the acI-B2 tribe, which seems to prefer acidic lakes. This enrichment grows to low cell densities and thus the oligotrophic nature of acI-B2 was confirmed. © 2013 Society for Applied Microbiology and John Wiley & Sons Ltd.

  16. 21 CFR 880.5510 - Non-AC-powered patient lift.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Non-AC-powered patient lift. 880.5510 Section 880... Devices § 880.5510 Non-AC-powered patient lift. (a) Identification. A non-AC-powered patient lift is a hydraulic, battery, or mechanically powered device, either fixed or mobile, used to lift and transport a...

  17. 21 CFR 880.5510 - Non-AC-powered patient lift.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Non-AC-powered patient lift. 880.5510 Section 880... Devices § 880.5510 Non-AC-powered patient lift. (a) Identification. A non-AC-powered patient lift is a hydraulic, battery, or mechanically powered device, either fixed or mobile, used to lift and transport a...

  18. Nuclear structure of 231Ac

    NASA Astrophysics Data System (ADS)

    Boutami, R.; Borge, M. J. G.; Mach, H.; Kurcewicz, W.; Fraile, L. M.; Gulda, K.; Aas, A. J.; García-Raffi, L. M.; Løvhøiden, G.; Martínez, T.; Rubio, B.; Taín, J. L.; Tengblad, O.

    2008-10-01

    The low-energy structure of 231Ac has been investigated by means of γ ray spectroscopy following the β decay of 231Ra. Multipolarities of 28 transitions have been established by measuring conversion electrons with a MINI-ORANGE electron spectrometer. The decay scheme of 231Ra → 231Ac has been constructed for the first time. The Advanced Time Delayed βγγ(t) method has been used to measure the half-lives of five levels. The moderately fast B(E1) transition rates derived suggest that the octupole effects, albeit weak, are still present in this exotic nucleus.

  19. Autographa californica multiple nucleopolyhedrovirus ac53 plays a role in nucleocapsid assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu Chao; Li Zhaofei; Wu Wenbi

    2008-12-05

    Autographa californica multiple nucleopolyhedrovirus (AcMNPV) orf53 (ac53) is a highly conserved gene existing in all sequenced Lepidoptera and Hymenoptera baculoviruses, but its function remains unknown. To investigate its role in the baculovirus life cycle, an ac53 deletion virus (vAc{sup ac53KO-PH-GFP}) was generated through homologous recombination in Escherichia coli. Fluorescence and light microscopy and titration analysis revealed that vAc{sup ac53KO-PH-GFP} could not produce infectious budded virus in infected Sf9 cells. Real-time PCR demonstrated that the ac53 deletion did not affect the levels of viral DNA replication. Electron microscopy showed that many lucent tubular shells devoid of the nucleoprotein core are presentmore » in the virogenic stroma and ring zone, indicating that the ac53 knockout affected nucleocapsid assembly. With a recombinant virus expressing an Ac53-GFP fusion protein, we observed that Ac53 was distributed within the cytoplasm and nucleus at 24 h post-infection, but afterwards accumulated predominantly near the nucleus-cytoplasm boundary. These data demonstrate that ac53 is involved in nucleocapsid assembly and is an essential gene for virus production.« less

  20. Load Designs For MJ Dense Plasma Foci

    NASA Astrophysics Data System (ADS)

    Link, A.; Povlius, A.; Anaya, R.; Anderson, M. G.; Angus, J. R.; Cooper, C. M.; Falabella, S.; Goerz, D.; Higginson, D.; Holod, I.; McMahon, M.; Mitrani, J.; Koh, E. S.; Pearson, A.; Podpaly, Y. A.; Prasad, R.; van Lue, D.; Watson, J.; Schmidt, A. E.

    2017-10-01

    Dense plasma focus (DPF) Z-pinches are compact pulse power driven devices with coaxial electrodes. The discharge of DPF consists of three distinct phases: first generation of a plasma sheath, plasma rail gun phase where the sheath is accelerated down the electrodes and finally an implosion phase where the plasma stagnates into a z-pinch geometry. During the z-pinch phase, DPFs can produce MeV ion beams, x-rays and neutrons. Megaampere class DPFs with deuterium fills have demonstrated neutron yields in the 1012 neutrons/shot range with pulse durations of 10-100 ns. Kinetic simulations using the code Chicago are being used to evaluate various load configurations from initial sheath formation to the final z-pinch phase for DPFs with up to 5 MA and 1 MJ coupled to the load. Results will be presented from the preliminary design simulations. LLNL-ABS-734785 This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory (LLNL) under Contract DE-AC52-07NA27344 and with support from the Computing Grand Challenge program at LLNL.

  1. Preionization Techniques in a kJ-Scale Dense Plasma Focus

    NASA Astrophysics Data System (ADS)

    Povilus, Alexander; Shaw, Brian; Chapman, Steve; Podpaly, Yuri; Cooper, Christopher; Falabella, Steve; Prasad, Rahul; Schmidt, Andrea

    2016-10-01

    A dense plasma focus (DPF) is a type of z-pinch device that uses a high current, coaxial plasma gun with an implosion phase to generate dense plasmas. These devices can accelerate a beam of ions to MeV-scale energies through strong electric fields generated by instabilities during the implosion of the plasma sheath. The formation of these instabilities, however, relies strongly on the history of the plasma sheath in the device, including the evolution of the gas breakdown in the device. In an effort to reduce variability in the performance of the device, we attempt to control the initial gas breakdown in the device by seeding the system with free charges before the main power pulse arrives. We report on the effectiveness of two techniques developed for a kJ-scale DPF at LLNL, a miniature primer spark gap and pulsed, 255nm LED illumination. Prepared by LLNL under Contract DE-AC52-07NA27344.

  2. Measuring the Refractive Index of a Laser-Plasma Optical System

    NASA Astrophysics Data System (ADS)

    Turnbull, D.; Goyon, C.; Pollock, B. B.; Mariscal, D.; Divol, L.; Ross, J. S.; Patankar, S.; Kemp, G. E.; Moody, J. D.; Michel, P. A.

    2016-10-01

    We report the first complete set of measurements of a laser-plasma optical system's refractive index, as seen by an independent probe laser beam, as a function of the relative wavelength shift between the two laser beams. Both the imaginary and real refractive-index components are found to be in good agreement with linear theory using plasma parameters measured by optical Thomson scattering and interferometry; the former is in contrast to previous work and has implications for cross-beam energy transfer in indirect-drive inertial confinement fusion, and the latter is measured for the first time. The data include the first demonstration of a laser-plasma polarizer with 85% to 87% extinction for the particular laser and plasma parameters used in this experiment, complementing the existing suite of high-power, tunable, and ultrafast plasma-based photonic devices. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  3. Plasma phospholipid fatty acid profiles in Korean adults with and without acute coronary syndrome

    USDA-ARS?s Scientific Manuscript database

    Background and Objectives: Acute coronary syndrome (ACS), a clinical manifestation of coronary artery disease presenting as unstable angina and/or myocardial infarction, is the third-leading cause of death in South Korea. Plasma phospholipid (PL) fatty acid profiles are considered objective biomarke...

  4. Optimization of spin-torque switching using AC and DC pulses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dunn, Tom; Kamenev, Alex; Fine Theoretical Physics Institute, University of Minnesota, Minneapolis, Minnesota 55455

    2014-06-21

    We explore spin-torque induced magnetic reversal in magnetic tunnel junctions using combined AC and DC spin-current pulses. We calculate the optimal pulse times and current strengths for both AC and DC pulses as well as the optimal AC signal frequency, needed to minimize the Joule heat lost during the switching process. The results of this optimization are compared against numeric simulations. Finally, we show how this optimization leads to different dynamic regimes, where switching is optimized by either a purely AC or DC spin-current, or a combination AC/DC spin-current, depending on the anisotropy energies and the spin-current polarization.

  5. Development of a DC Glow Discharge Exhibit for the Demonstration of Plasma Behavior in a Magnetic Field

    NASA Astrophysics Data System (ADS)

    Bruder, Daniel

    2010-11-01

    The DC Glow Discharge Exhibit is intended to demonstrate the effects a magnetic field produces on a plasma in a vacuum chamber. The display, which will be featured as a part of The Liberty Science Center's ``Energy Quest Exhibition,'' consists of a DC glow discharge tube and information panels to educate the general public on plasma and its relation to fusion energy. Wall posters and an information booklet will offer brief descriptions of fusion-based science and technology, and will portray plasma's role in the development of fusion as a viable source of energy. The display features a horse-shoe magnet on a movable track, allowing viewers to witness the effects of a magnetic field upon a plasma. The plasma is created from air within a vacuum averaging between 100-200 mTorr. Signage within the casing describes the hardware components. The display is pending delivery to The Liberty Science Center, and will replace a similar, older exhibit presently at the museum.

  6. AC power generation from microbial fuel cells

    NASA Astrophysics Data System (ADS)

    Lobo, Fernanda Leite; Wang, Heming; Forrestal, Casey; Ren, Zhiyong Jason

    2015-11-01

    Microbial fuel cells (MFCs) directly convert biodegradable substrates to electricity and carry good potential for energy-positive wastewater treatment. However, the low and direct current (DC) output from MFC is not usable for general electronics except small sensors, yet commercial DC-AC converters or inverters used in solar systems cannot be directly applied to MFCs. This study presents a new DC-AC converter system for MFCs that can generate alternating voltage in any desired frequency. Results show that AC power can be easily achieved in three different frequencies tested (1, 10, 60 Hz), and no energy storage layer such as capacitors was needed. The DC-AC converter efficiency was higher than 95% when powered by either individual MFCs or simple MFC stacks. Total harmonic distortion (THD) was used to investigate the quality of the energy, and it showed that the energy could be directly usable for linear electronic loads. This study shows that through electrical conversion MFCs can be potentially used in household electronics for decentralized off-grid communities.

  7. Ozone and dinitrogen monoxide production in atmospheric pressure air dielectric barrier discharge plasma effluent generated by nanosecond pulse superimposed alternating current voltage

    NASA Astrophysics Data System (ADS)

    Takashima, Keisuke; Kaneko, Toshiro

    2017-06-01

    The effects of nanosecond pulse superposition to alternating current voltage (NS + AC) on the generation of an air dielectric barrier discharge (DBD) plasma and reactive species are experimentally studied, along with measurements of ozone (O3) and dinitrogen monoxide (N2O) in the exhausted gas through the air DBD plasma (air plasma effluent). The charge-voltage cycle measurement indicates that the role of nanosecond pulse superposition is to induce electrical charge transport and excess charge accumulation on the dielectric surface following the nanosecond pulses. The densities of O3 and N2O in NS + AC DBD are found to be significantly increased in the plasma effluent, compared to the sum of those densities generated in NS DBD and AC DBD operated individually. The production of O3 and N2O is modulated significantly by the phase in which the nanosecond pulse is superimposed. The density increase and modulation effects by the nanosecond pulse are found to correspond with the electrical charge transport and the excess electrical charge accumulation induced by the nanosecond pulse. It is suggested that the electrical charge transport by the nanosecond pulse might result in the enhancement of the nanosecond pulse current, which may lead to more efficient molecular dissociation, and the excess electrical charge accumulation induced by the nanosecond pulse increases the discharge coupling power which would enhance molecular dissociation.

  8. A Single-Phase Embedded Z-Source DC-AC Inverter

    PubMed Central

    Kim, Se-Jin; Lim, Young-Cheol

    2014-01-01

    In the conventional DC-AC inverter consisting of two DC-DC converters with unipolar output capacitors, the output capacitor voltages of the DC-DC converters must be higher than the DC input voltage. To overcome this weakness, this paper proposes a single-phase DC-AC inverter consisting of two embedded Z-source converters with bipolar output capacitors. The proposed inverter is composed of two embedded Z-source converters with a common DC source and output AC load. Though the output capacitor voltages of the converters are relatively low compared to those of a conventional inverter, an equivalent level of AC output voltages can be obtained. Moreover, by controlling the output capacitor voltages asymmetrically, the AC output voltage of the proposed inverter can be higher than the DC input voltage. To verify the validity of the proposed inverter, experiments were performed with a DC source voltage of 38 V. By controlling the output capacitor voltages of the converters symmetrically or asymmetrically, the proposed inverter can produce sinusoidal AC output voltages. The experiments show that efficiencies of up to 95% and 97% can be achieved with the proposed inverter using symmetric and asymmetric control, respectively. PMID:25133241

  9. A single-phase embedded Z-source DC-AC inverter.

    PubMed

    Kim, Se-Jin; Lim, Young-Cheol

    2014-01-01

    In the conventional DC-AC inverter consisting of two DC-DC converters with unipolar output capacitors, the output capacitor voltages of the DC-DC converters must be higher than the DC input voltage. To overcome this weakness, this paper proposes a single-phase DC-AC inverter consisting of two embedded Z-source converters with bipolar output capacitors. The proposed inverter is composed of two embedded Z-source converters with a common DC source and output AC load. Though the output capacitor voltages of the converters are relatively low compared to those of a conventional inverter, an equivalent level of AC output voltages can be obtained. Moreover, by controlling the output capacitor voltages asymmetrically, the AC output voltage of the proposed inverter can be higher than the DC input voltage. To verify the validity of the proposed inverter, experiments were performed with a DC source voltage of 38 V. By controlling the output capacitor voltages of the converters symmetrically or asymmetrically, the proposed inverter can produce sinusoidal AC output voltages. The experiments show that efficiencies of up to 95% and 97% can be achieved with the proposed inverter using symmetric and asymmetric control, respectively.

  10. Experimental results from plasma transport on Prototype-Material Plasma Exposure eXperiment and comparison with B2-Eirene modeling

    NASA Astrophysics Data System (ADS)

    Kafle, N.; Caneses, J. F.; Biewer, T. M.; Owen, L.; Showers, M.; Donovan, D.; Caughman, J. B.; Goulding, R. H.; Rapp, Juergen

    2017-10-01

    Proto-MPEX at ORNL is a linear plasma device that combines a helicon plasma source with additional microwave and RF heating to deliver high plasma heat and particle fluxes to a target. Double Langmuir probes and Thomson scattering are being used to measure local Te and ne at various radial and axial locations. A recently constructed Mach- double probe provides the added capability of simultaneously measuring Te, ne, and Mach number. With this diagnostic, it is possible to infer the plasma flow, particle flux, and convective heat flux at different locations along the plasma column in Proto-MPEX. Preliminary results show Mach numbers of 0.6 and 0.8 in either direction away from the helicon source, and no flow near the source for the case where the peak magnetic field was 1.0 T. In addition, the Thomson Scattering system has been upgraded to measure ne and Te profiles at two axial locations, upstream at the electron heating location and downstream close to the target. Measurements of particle flow and flux profiles, heat flux, and profiles of ne and Te will be discussed. The extensive coverage provided by these diagnostics permits data-constrained B2-Eirene modeling of the entire plasma column, and comparison with results of modeling of high density mode plasmas will be presented. Supported by the US. D.O.E. contract DE-AC05-00OR22725.

  11. Post-Flash Validation of the new ACS/WFC Subarrays

    NASA Astrophysics Data System (ADS)

    Bellini, A.; Grogin, N. A.; Lim, P. L.; Golimowski, D.

    2017-05-01

    We made use of the new ACS/WFC subarray images of CAL-14410, taken taken with a large range of flash exposure times (0.1-30 seconds), to probe the temporal stability of the reference flash file and to validate the current post-flash correction pipeline of CALACS and ACS DESTRIPE PLUS on the new subarray modes. No statistically-significant deviations are found between the new post-flashed subarray exposures and the flash reference file, indicating that the LED lamp used to post-flash ACS images has been stable over several years. The current calibration pipelines (both CALACS and ACS DESTRIPE PLUS can be successfully used with the new subarray modes.

  12. Advanced Design Concepts for Dense Plasma Focus Devices at LLNL

    NASA Astrophysics Data System (ADS)

    Povilus, Alexander; Podpaly, Yuri; Cooper, Christopher; Shaw, Brian; Chapman, Steve; Mitrani, James; Anderson, Michael; Pearson, Aric; Anaya, Enrique; Koh, Ed; Falabella, Steve; Link, Tony; Schmidt, Andrea

    2017-10-01

    The dense plasma focus (DPF) is a z-pinch device where a plasma sheath is accelerated down a coaxial railgun and ends in a radial implosion, pinch phase. During the pinch phase, the plasma generates intense, transient electric fields through physical mechanisms, similar to beam instabilities, that can accelerate ions in the plasma sheath to MeV-scale energies on millimeter length scales. Using kinetic modeling techniques developed at LLNL, we have gained insight into the formation of these accelerating fields and are using these observations to optimize the behavior of the generated ion beam for producing neutrons via beam-target interactions for kilojoule to megajoule-scale devices. Using a set of DPF's, both in operation and in development at LLNL, we have explored critical aspects of these devices, including plasma sheath formation behavior, power delivery to the plasma, and instability seeding during the implosion in order to improve the absolute yield and stability of the device. Prepared by LLNL under Contract DE-AC52-07NA27344. Computing support for this work came from the LLNL Institutional Computing Grand Challenge program.

  13. Flat panel displays in the helmet-mounted display

    NASA Astrophysics Data System (ADS)

    Bartlett, Christopher T.; Freeman, Jonathan P.

    2002-08-01

    The Helmet Mounted Display has been in development for over 25 years and with few exceptions those systems in service have incorporated a miniature Cathode Ray Tube as the display source. The exceptions have been the use of Light Emitting Diodes in Helmet Sighting displays. The argument for Flat Panel Displays has been well rehearsed and this paper provides a summary of the available technologies but with a rationale for a decision to use Reflective Liquid Crystal devices. The Paper then describes sources of illumination and derives the luminance required from that source.

  14. Flexible, polymer gated, AC-driven organic electroluminescence devices

    NASA Astrophysics Data System (ADS)

    Xu, Junwei; Carroll, David L.

    2017-08-01

    Comparing rigid inorganic layer, polymeric semiconducting gate layer exhibits superior flexibility as well as efficient carrier manipulation in high frequency AC cycles. Mechanism of the carrier manipulation at the gate in forward and reversed bias of AC cycle is studied. The flexible PET-based AC-OEL device with poly[(9,9-bis(3'-((N,N-dimethyl)-Nethylammonium)- propyl)-2,7-fluorene)-alt-2,7-(9,9-dioctylfluorene)] (PFN-Br) gate shows a stable electroluminescent performance in frequency sweep with a color rendering index (CRI) over 81 at 2800K color temperature.

  15. EDITORIAL: Non-thermal plasma-assisted fuel conversion for green chemistry Non-thermal plasma-assisted fuel conversion for green chemistry

    NASA Astrophysics Data System (ADS)

    Nozaki, Tomohiro; Gutsol, Alexander

    2011-07-01

    This special issue is based on the symposium on Non-thermal Plasma Assisted Fuel Conversion for Green Chemistry, a part of the 240th ACS National Meeting & Exposition held in Boston, MA, USA, 22-26 August 2010. Historically, the Division of Fuel Chemistry of the American Chemical Society (ACS) has featured three plasma-related symposia since 2000, and has launched special issues in Catalysis Today on three occasions: 'Catalyst Preparation using Plasma Technologies', Fall Meeting, Washington DC, USA, 2000. Special issue in Catalysis Today 72 (3-4) with 12 peer-reviewed articles. 'Plasma Technology and Catalysis', Spring Meeting, New Orleans, LA, USA, 2003. Special issue in Catalysis Today 89 (1-2) with more than 30 peer-reviewed articles. 'Utilization of Greenhouse Gases II' (partly focused on plasma-related technologies), Spring Meeting, Anaheim, CA, USA, 2004. Special issue in Catalysis Today 98 (4) with 25 peer-reviewed articles. This time, selected presentations are published in this Journal of Physics D: Applied Physics special issue. An industrial material and energy conversion technology platform is established on thermochemical processes including various catalytic reactions. Existing industry-scale technology is already well established; nevertheless, further improvement in energy efficiency and material saving has been continuously demanded. Drastic reduction of CO2 emission is also drawing keen attention with increasing recognition of energy and environmental issues. Green chemistry is a rapidly growing research field, and frequently highlights renewable bioenergy, bioprocesses, solar photocatalysis of water splitting, and regeneration of CO2 into useful chemicals. We would also like to emphasize 'plasma catalysis' of hydrocarbon resources as an important part of the innovative next-generation green technologies. The peculiarity of non-thermal plasma is that it can generate reactive species almost independently of reaction temperature. Plasma

  16. dc Arc Fault Effect on Hybrid ac/dc Microgrid

    NASA Astrophysics Data System (ADS)

    Fatima, Zahra

    The advent of distributed energy resources (DER) and reliability and stability problems of the conventional grid system has given rise to the wide spread deployment of microgrids. Microgrids provide many advantages by incorporating renewable energy sources and increasing the reliability of the grid by isolating from the main grid in case of an outage. AC microgrids have been installed all over the world, but dc microgrids have been gaining interest due to the advantages they provide over ac microgrids. However the entire power network backbone is still ac and dc microgrids require expensive converters to connect to the ac power network. As a result hybrid ac/dc microgrids are gaining more attention as it combines the advantages of both ac and dc microgrids such as direct integration of ac and dc systems with minimum number of conversions which increases the efficiency by reducing energy losses. Although dc electric systems offer many advantages such as no synchronization and no reactive power, successful implementation of dc systems requires appropriate protection strategies. One unique protection challenge brought by the dc systems is dc arc faults. A dc arc fault is generated when there is a gap in the conductor due to insulation degradation and current is used to bridge the gap, resulting in an arc with very high temperature. Such a fault if it goes undetected and is not extinguished can cause damage to the entire system and cause fires. The purpose of the research is to study the effect of the dc arc fault at different locations in the hybrid ac/dc microgrid and provide insight on the reliability of the grid components when it is impacted by arc faults at various locations in the grid. The impact of dc arc fault at different locations on the performance of the PV array, wind generation, and constant power loads (CPL) interfaced with dc/dc converters is studied. MATLAB/Simulink is used to model the hybrid ac/dc microgrid and arc fault.

  17. Foundations of atmospheric pressure non-equilibrium plasmas

    NASA Astrophysics Data System (ADS)

    Bruggeman, Peter J.; Iza, Felipe; Brandenburg, Ronny

    2017-12-01

    Non-equilibrium plasmas have been intensively studied over the past century in the context of material processing, environmental remediation, ozone generation, excimer lamps and plasma display panels. Research on atmospheric pressure non-equilibrium plasmas intensified over the last two decades leading to a large variety of plasma sources that have been developed for an extended application range including chemical conversion, medicine, chemical analysis and disinfection. The fundamental understanding of these discharges is emerging but there remain a lot of unexplained phenomena in these intrinsically complex plasmas. The properties of non-equilibrium plasmas at atmospheric pressure span over a huge range of electron densities as well as heavy particle and electron temperatures. This paper provides an overview of the key underlying processes that are important for the generation and stabilization of atmospheric pressure non-equilibrium plasmas. The unique physical and chemical properties of theses discharges are also summarized.

  18. Finding-specific display presets for computed radiography soft-copy reading.

    PubMed

    Andriole, K P; Gould, R G; Webb, W R

    1999-05-01

    Much work has been done to optimize the display of cross-sectional modality imaging examinations for soft-copy reading (i.e., window/level tissue presets, and format presentations such as tile and stack modes, four-on-one, nine-on-one, etc). Less attention has been paid to the display of digital forms of the conventional projection x-ray. The purpose of this study is to assess the utility of providing presets for computed radiography (CR) soft-copy display, based not on the window/level settings, but on processing applied to the image optimized for visualization of specific findings, pathologies, etc (i.e., pneumothorax, tumor, tube location). It is felt that digital display of CR images based on finding-specific processing presets has the potential to: speed reading of digital projection x-ray examinations on soft copy; improve diagnostic efficacy; standardize display across examination type, clinical scenario, important key findings, and significant negatives; facilitate image comparison; and improve confidence in and acceptance of soft-copy reading. Clinical chest images are acquired using an Agfa-Gevaert (Mortsel, Belgium) ADC 70 CR scanner and Fuji (Stamford, CT) 9000 and AC2 CR scanners. Those demonstrating pertinent findings are transferred over the clinical picture archiving and communications system (PACS) network to a research image processing station (Agfa PS5000), where the optimal image-processing settings per finding, pathologic category, etc, are developed in conjunction with a thoracic radiologist, by manipulating the multiscale image contrast amplification (Agfa MUSICA) algorithm parameters. Soft-copy display of images processed with finding-specific settings are compared with the standard default image presentation for 50 cases of each category. Comparison is scored using a 5-point scale with the positive scale denoting the standard presentation is preferred over the finding-specific processing, the negative scale denoting the finding

  19. Frequency-dependent tACS modulation of BOLD signal during rhythmic visual stimulation.

    PubMed

    Chai, Yuhui; Sheng, Jingwei; Bandettini, Peter A; Gao, Jia-Hong

    2018-05-01

    Transcranial alternating current stimulation (tACS) has emerged as a promising tool for modulating cortical oscillations. In previous electroencephalogram (EEG) studies, tACS has been found to modulate brain oscillatory activity in a frequency-specific manner. However, the spatial distribution and hemodynamic response for this modulation remains poorly understood. Functional magnetic resonance imaging (fMRI) has the advantage of measuring neuronal activity in regions not only below the tACS electrodes but also across the whole brain with high spatial resolution. Here, we measured fMRI signal while applying tACS to modulate rhythmic visual activity. During fMRI acquisition, tACS at different frequencies (4, 8, 16, and 32 Hz) was applied along with visual flicker stimulation at 8 and 16 Hz. We analyzed the blood-oxygen-level-dependent (BOLD) signal difference between tACS-ON vs tACS-OFF, and different frequency combinations (e.g., 4 Hz tACS, 8 Hz flicker vs 8 Hz tACS, 8 Hz flicker). We observed significant tACS modulation effects on BOLD responses when the tACS frequency matched the visual flicker frequency or the second harmonic frequency. The main effects were predominantly seen in regions that were activated by the visual task and targeted by the tACS current distribution. These findings bridge different scientific domains of tACS research and demonstrate that fMRI could localize the tACS effect on stimulus-induced brain rhythms, which could lead to a new approach for understanding the high-level cognitive process shaped by the ongoing oscillatory signal. © 2018 Wiley Periodicals, Inc.

  20. Apple MdACS6 Regulates Ethylene Biosynthesis During Fruit Development Involving Ethylene-Responsive Factor.

    PubMed

    Li, Tong; Tan, Dongmei; Liu, Zhi; Jiang, Zhongyu; Wei, Yun; Zhang, Lichao; Li, Xinyue; Yuan, Hui; Wang, Aide

    2015-10-01

    Ethylene biosynthesis in plants involves different 1-aminocyclopropane-1-carboxylic acid synthase (ACS) genes. The regulation of each ACS gene during fruit development is unclear. Here, we characterized another apple (Malus×domestica) ACS gene, MdACS6. The transcript of MdACS6 was observed not only in fruits but also in other tissues. During fruit development, MdACS6 was initiated at a much earlier stage, whereas MdACS3a and MdACS1 began to be expressed at 35 d before harvest and immediateley after harvest, respectively. Moreover, the enzyme activity of MdACS6 was significantly lower than that of MdACS3a and MdACS1, accounting for the low ethylene biosynthesis in young fruits. Overexpression of MdACS6 (MdACS6-OE) by transient assay in apple showed enhanced ethylene production, and MdACS3a was induced in MdACS6-OE fruits but not in control fruits. In MdACS6 apple fruits silenced by the virus-induced gene silencing (VIGS) system (MdACS6-AN), neither ethylene production nor MdACS3a transcript was detectable. In order to explore the mechanism through which MdACS3a was induced in MdACS6-OE fruits, we investigated the expression of apple ethylene-responsive factor (ERF) genes. The results showed that the expression of MdERF2 was induced in MdACS6-OE fruits and inhibited in MdACS6-AN fruits. Yeast one-hybrid assay showed that MdERF2 protein could bind to the promoter of MdACS3a. Moreover, down-regulation of MdERF2 in apple flesh callus led to a decrease of MdACS3a expression, demonstrating the regulation of MdERF2 on MdACS3a. The mechanism through which MdACS6 regulates the action of MdACS3a was discussed. © The Author 2015. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  1. Ac electroosmotic flows above coplanar electrodes

    NASA Astrophysics Data System (ADS)

    Kweon Suh, Yong

    2009-03-01

    Interactive numerical method has been proposed to calculate the ac electroosmotic flows above a pair of coplanar electrodes. The thin electrical triple layer (ETL) has been modeled by an asymptotic theory developed by the authors. The model corresponds to a simple dynamic equation for the surface charge density representing the integrated charge over the inner layer. Interactive calculation of the dynamic equation and the Laplace equation for several periods of ac frequency then yielded steady-state distribution of potential and the potential drop across the Stern and inner layers. The Smoluchowski's slip velocity was then determined from those two set of data and used as the boundary condition for the calculation of the Stokes' flow above the electrodes. We have shown that our solutions compared well with the experimental data reported in the literature. We investigated the effect of various parameters on the slip velocity distribution, such as the ac frequency, the electrode length, the effective Stern-layer thickness and the adsorption coefficients.

  2. Platelet-Rich Plasma (PRP) for Acute Muscle Injury: A Systematic Review

    PubMed Central

    A. Hamid, Mohamad Shariff; Yusof, Ashril; Mohamed Ali, Mohamed Razif

    2014-01-01

    Introduction Acute muscle injury is one of the commonest injuries that often result in loss of training and competition time. The best management for muscle injury has not been identified. Sports medicine practitioners used several approaches in attempt to accelerate time to recovery from muscle injury. More recently growing interest focussed on autologous blood product injection. Methods A literature search was conducted systematically using OvidMEDLINE, PubMed, EMBASE, SPORTDiscus and CINAHL databases to retrieve articles published until December 2012. Controlled trials and controlled laboratory studies comparing different strategies to promote early recovery of muscle injury were included. The methodological quality of studies was assessed. Results There are limited studies on the effects of PRP therapy for muscle injury. Three in vivo laboratory studies and one pilot human study were reviewed. The laboratory studies reported histological evidence on significant acceleration of muscle healing in animals treated with autologous conditioned serum (ACS), platelet-rich plasma (PRP) and platelet rich fibrin matrix (PRFM). A pilot human study found athletes treated with repeated ACS injection recovers significantly faster than retrospective controls. Conclusion Several in vivo laboratory studies suggest beneficial effects of ACS, PRP and PRFM in accelerating muscle recovery. Evidence to suggest similar effects on humans is however limited, as valuable information from robust human controlled trials is still not available at this moment. Hence, more studies of satisfactory methodological quality with platelet-rich plasma interventions on muscle injury are justified. PMID:24587389

  3. Excitation of Ion Acoustic Waves in Confined Plasmas with Untrapped Electrons

    NASA Astrophysics Data System (ADS)

    Schamis, Hanna; Dow, Ansel; Carlsson, Johan; Kaganovich, Igor; Khrabrov, Alexander

    2015-11-01

    Various plasma propulsion devices exhibit strong electron emission from the walls either as a result of secondary processes or due to thermionic emission. To understand the electron kinetics in plasmas with strong emission, we have performed simulations using a reduced model with the LSP particle-in-cell code. This model aims to show the instability generated by the electron emission, in the form of ion acoustic waves near the sheath. It also aims to show the instability produced by untrapped electrons that propagate across the plasma, similarly to a beam, and can drive ion acoustic waves in the plasma bulk. This work was made possible by funding from the Department of Energy for the Summer Undergraduate Laboratory Internship (SULI) program. This work is supported by the US DOE Contract No.DE-AC02-09CH11466.

  4. An AC electroosmotic micropump for circular chromatographic applications.

    PubMed

    Debesset, S; Hayden, C J; Dalton, C; Eijkel, J C T; Manz, A

    2004-08-01

    Flow rates of up to 50 microm s(-1) have been successfully achieved in a closed-loop channel using an AC electroosmotic pump. The AC electroosmotic pump is made of an interdigitated array of unequal width electrodes located at the bottom of a channel, with an AC voltage applied between the small and the large electrodes. The flow rate was found to increase linearly with the applied voltage and to decrease linearly with the applied frequency. The pump is expected to be suitable for circular chromatography for the following reasons: the driving forces are distributed over the channel length and the pumping direction is set by the direction of the interdigitated electrodes. Pumping in a closed-loop channel can be achieved by arranging the electrode pattern in a circle. In addition the inherent working principle of AC electroosmotic pumping enables the independent optimisation of the channel height or the flow velocity.

  5. Characterizing superconducting thin films using AC Magnetic Susceptibility

    NASA Astrophysics Data System (ADS)

    Mahoney, C. H.; Porzio, J.; Sullivan, M. C.

    2014-03-01

    We present our work on using ac magnetic susceptibility to determine the critical temperature of superconducting thin films. In ac magnetic susceptibility, the thin film is placed between two coils. One coil carries an ac signal, creating a varying external magnetic field. We measure the voltage induced in the pick-up coil on the opposite side of the sample and measure how the sample magnetization changes as the temperature changes. We will present our work to use ac susceptibility to determine critical temperature and superconducting volume fraction. Using our own analysis program, we are able to accurately locate the critical temperatures of the samples and determine the transition width. For the superconducting volume fraction, we etch samples in order to control the thicknesses of the sample and measure how much of the material grown on the surface is superconducting. Supported by NFS grant DMR-1305637.

  6. A heptadecanuclear Mn(III)9Dy(III)8 cluster derived from triethanolamine with two edge sharing supertetrahedra as the core and displaying SMM behaviour.

    PubMed

    Langley, Stuart K; Moubarakia, Boujemaa; Murray, Keith S

    2010-06-07

    A heterometallic, heptadecanuclear cluster of formula [Mn(III)9Dy(III)8O8(OH)8(tea)2(teaH)2(teaH2)4(Ac)4(NO3)2(H2O)4](NO3)7·8H2O (1) is reported. The core of 1 displays two edge sharing Mn(III)5Dy(III)5 supertetrahedra and represents one of the largest Mn/4f cluster compound so far reported. Magnetic studies show that 1 displays probable SMM behaviour as observed via non-zero values in the χM''vs T plot.

  7. [Effect of wenxin granule on plasma BNP and HRV of acute coronary syndrome patients].

    PubMed

    Peng, Jie-cheng; Su, Jia-feng; Hong, Li-ping; Xia, Lin-feng; Yan, Wei-guo

    2013-08-01

    To observe the effect of Wenxin Granule (WG) on brain natriuretic peptide (BNP) and heart rate variability (HRV) of acute coronary syndrome (ACS) patients. Totally 65 ACS patients were randomly assigned to the treatment group (35 cases) and the control group (30 cases). All patients were treated with routine therapies such as angiotensin conversing enzyme inhibitors (ACEI) and metoprolol. Those in the treatment group took WG, 9 g each time, three times daily. All were treated for 90 days. Plasma samples of BNP and HRV were determined before treatment and after treatment. There was no statistical difference in pre-treatment plasma BNP (P > 0.05). Plasma BNP significantly decreased after treatment in the two groups when compared with before treatment (P < 0.05). The decrease was more obvious in the treatment group (P < 0.05). There was no statistical difference in pre-treatment HRV (P > 0.05). Compared with before treatment in the same group, RMSSD, PNN50%, and high frequency (HF) obviously increased, while low frequency (LF) and LF/HF ratio significantly decreased in the two groups, showing statistical difference (P < 0.05). The aforesaid indices were obviously better in the treatment group than in the control group (P < 0.05). Additional administration of WG could improve short-term clinical prognosis by down-regulating plasma BNP level (via improving myocardial ischemia) and modulating HRV.

  8. AMPS data management requirements study, appendix 1. [user manuals (computer programs)/display devices - computerized simulation/experimentation/ionosphere

    NASA Technical Reports Server (NTRS)

    1975-01-01

    Flow charts and display formats for the simulation of five experiments are given. The experiments are: (1) electromagnetic wave transmission; (2) passive observations of ambient plasma; (3) ionospheric measurements with subsatellite; (4) electron accelerator beam measurements; and (5) measurement of acoustical gravity waves in the sodium layer using lasers. A detailed explanation of the simulation procedure, definition of variables, and an explanation of how the experimenter makes display choices is also presented. A functional description is included on each flow chart and the assumptions and definitions of terms and scope of the flow charts and displays are presented.

  9. Association between plant-based diets and plasma lipids: a systematic review and meta-analysis.

    PubMed

    Yokoyama, Yoko; Levin, Susan M; Barnard, Neal D

    2017-09-01

    . Available at: https://www.crd.york.ac.uk/PROSPERO/display_record.asp?ID=CRD42015023783. © The Author(s) 2017. Published by Oxford University Press on behalf of the International Life Sciences Institute.

  10. Association between plant-based diets and plasma lipids: a systematic review and meta-analysis

    PubMed Central

    Yokoyama, Yoko; Levin, Susan M; Barnard, Neal D

    2017-01-01

    high-density lipoprotein cholesterol, but not with decreased triglycerides. Systematic Review Registration PROSPERO number CRD42015023783. Available at: https://www.crd.york.ac.uk/PROSPERO/display_record.asp?ID=CRD42015023783. PMID:28938794

  11. Evolution of beams in a plasma channel due to beam break up

    NASA Astrophysics Data System (ADS)

    Penn, Gregory; Lehe, Remi; Vay, Jean-Luc; Schroeder, Carl; Esarey, Eric

    2016-10-01

    We study the dynamics of beam break-up (BBU) of an accelerated electron beam in a plasma channel. Particle-in-cell simulations using the codes WARP and FBPIC are presented and interpreted in terms of theoretical calculations for the plasma-induced fields and the evolution of the instability. We focus on cylindrical channels for simplicity, and other geometries are considered to better understand the impact of BBU on electron beams undergoing laser-plasma wake field acceleration. We compare our findings with other published results. This work was supported by the Director, Office of Science, Office of High Energy Physics, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231.

  12. Introducing high performance distributed logging service for ACS

    NASA Astrophysics Data System (ADS)

    Avarias, Jorge A.; López, Joao S.; Maureira, Cristián; Sommer, Heiko; Chiozzi, Gianluca

    2010-07-01

    The ALMA Common Software (ACS) is a software framework that provides the infrastructure for the Atacama Large Millimeter Array and other projects. ACS, based on CORBA, offers basic services and common design patterns for distributed software. Every properly built system needs to be able to log status and error information. Logging in a single computer scenario can be as easy as using fprintf statements. However, in a distributed system, it must provide a way to centralize all logging data in a single place without overloading the network nor complicating the applications. ACS provides a complete logging service infrastructure in which every log has an associated priority and timestamp, allowing filtering at different levels of the system (application, service and clients). Currently the ACS logging service uses an implementation of the CORBA Telecom Log Service in a customized way, using only a minimal subset of the features provided by the standard. The most relevant feature used by ACS is the ability to treat the logs as event data that gets distributed over the network in a publisher-subscriber paradigm. For this purpose the CORBA Notification Service, which is resource intensive, is used. On the other hand, the Data Distribution Service (DDS) provides an alternative standard for publisher-subscriber communication for real-time systems, offering better performance and featuring decentralized message processing. The current document describes how the new high performance logging service of ACS has been modeled and developed using DDS, replacing the Telecom Log Service. Benefits and drawbacks are analyzed. A benchmark is presented comparing the differences between the implementations.

  13. Nonlocal Ohms Law, Plasma Resistivity, and Reconnection During Collisions of Magnetic Flux Ropes

    NASA Astrophysics Data System (ADS)

    Gekelman, W.; DeHaas, T.; Pribyl, P.; Vincena, S.; Van Compernolle, B.; Sydora, R.; Tripathi, S. K. P.

    2018-01-01

    The plasma resistivity was evaluated in an experiment on the collision of two magnetic flux ropes. Whenever the ropes collide, some magnetic energy is lost as a result of reconnection. Volumetric data, in which all the relevant time-varying quantities were recorded in detail, are presented. Ohm’s law is shown to be nonlocal and cannot be used to evaluate the plasma resistivity. The resistivity was instead calculated using the AC Kubo resistivity and shown to be anomalously high in certain regions of space.

  14. Application field and ways to control alternating-current plasma torch with rail electrodes

    NASA Astrophysics Data System (ADS)

    Kuznetsov, V. E.; Safronov, A. A.; Vasilieva, O. B.; Shiryaev, V. N.; Dudnik, Yu D.; Pavlov, A. V.; Kuchina, Yu A.

    2018-01-01

    The paper deals with the investigation of parameters of the high voltage alternating-current plasma torch with rail electrodes. Usage of the injector and its variation allows controlling of operation of the ac plasma torch with rail electrodes. Also the possibility to protect the electric arc chamber without protective gas has been studied. It was found that increasing in the injector power causes the repeated breakdown at lower voltage and hence the arc dimensions decreases. The results of experiments are presented in the paper.

  15. Manipulation of the polarization of intense laser beams via optical wave mixing in plasmas

    NASA Astrophysics Data System (ADS)

    Michel, Pierre; Divol, Laurent; Turnbull, David; Moody, John

    2014-10-01

    When intense laser beams overlap in plasmas, the refractive index modulation created by the beat wave via the ponderomotive force can lead to optical wave mixing phenomena reminiscent of those used in crystals and photorefractive materials. Using a vector analysis, we present a full analytical description of the modification of the polarization state of laser beams crossing at arbitrary angles in a plasma. We show that plasmas can be used to provide full control of the polarization state of a laser beam, and give simple analytical estimates and practical considerations for the design of novel photonics devices such as plasma polarizers and plasma waveplates. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract No. DE-AC52-07NA27344.

  16. Particle Line Assembly/Patterning by Microfluidic AC Electroosmosis

    NASA Astrophysics Data System (ADS)

    Lian, Meng; Islam, Nazmul; Wu, Jie

    2006-04-01

    Recently AC electroosmosis has attracted research interests worldwide. This paper is the first to investigate particle line assembly/patterning by AC electroosmosis. Since AC electroosmotic force has no dependence on particle sizes, this technique is particularly useful for manipulating nanoscale substance, and hopefully constructs functional nanoscale devices. Two types of ACEO devices, in the configurations of planar interdigitated electrodes and parallel plate electrodes, and a biased ACEO technique are studied, which provides added flexibility in particle manipulation and line assembly. The paper also investigates the effects of electrical field distributions on generating microflows for particle assembly. The results are corroborated experimentally.

  17. Display formats manual

    NASA Technical Reports Server (NTRS)

    Runnels, R. L.

    1973-01-01

    The standards and procedures for the generation of operational display formats to be used in the Mission Control Center (MCC) display control system are presented. The required effort, forms, and fundamentals for the design, specifications, and production of display formats are identified. The principles of display design and system constraints controlling the creation of optimum operational displays for mission control are explained. The basic two types of MCC display systems for presenting information are described.

  18. Sequencing analysis of ghrelin gene 5' flanking region: relations between the sequence variants, fasting plasma total ghrelin concentrations, and body mass index.

    PubMed

    Vartiainen, Johanna; Kesäniemi, Y Antero; Ukkola, Olavi

    2006-10-01

    Ghrelin is a 28-amino-acid peptide with several functions linked to energy metabolism. Low ghrelin plasma concentrations are associated with obesity, hypertension, and type 2 diabetes mellitus, whereas high concentrations reflect states of negative energy balance. Several studies addressing the hormonal and neural regulation of ghrelin gene expression have been carried out, but the role of genetic factors in the regulation of ghrelin plasma levels remains unclear. To elucidate the role of genetic factors in the regulation of ghrelin expression, we screened 1657 nucleotides of the ghrelin gene 5' flanking region (promoter and possible regulatory sites) for new sequential variations from patient samples with low (n = 50) and high (n = 50) fasting plasma total ghrelin concentrations (low- and high-ghrelin groups). Eleven single nucleotide polymorphisms (SNPs), 3 of which were rare variants (allelic frequency less than 1%) were found in our population. The genotype distribution patterns of the SNPs did not differ between the study groups, except for SNP-501A>C (P = .039). In addition, the SNP-01A>C was associated with body mass index (BMI) (P = .018). This variant was studied further in our large and well-defined Oulu Project Elucidating Risk for Atherosclerosis (OPERA) cohort (n = 1045) by the restriction fragment length polymorphism (RFLP) technique. No significant association of SNP-501A>C genotypes with fasting ghrelin plasma concentrations was found in the whole OPERA population. However, the association of this SNP with BMI and with waist circumference reached statistical significance in OPERA (P = .047 and .049, respectively), remaining of borderline significance for BMI after adjustments (P = .055). The results indicate that factors other than the 11 SNPs found in this study in the 5' flanking region of ghrelin gene are the main determinants of ghrelin plasma levels. However, SNP-501 A>C genotype distribution seems to be different in subjects having the highest

  19. Identification of new intrinsic proteins in Arabidopsis plasma membrane proteome.

    PubMed

    Marmagne, Anne; Rouet, Marie-Aude; Ferro, Myriam; Rolland, Norbert; Alcon, Carine; Joyard, Jacques; Garin, Jérome; Barbier-Brygoo, Hélène; Ephritikhine, Geneviève

    2004-07-01

    Identification and characterization of anion channel genes in plants represent a goal for a better understanding of their central role in cell signaling, osmoregulation, nutrition, and metabolism. Though channel activities have been well characterized in plasma membrane by electrophysiology, the corresponding molecular entities are little documented. Indeed, the hydrophobic protein equipment of plant plasma membrane still remains largely unknown, though several proteomic approaches have been reported. To identify new putative transport systems, we developed a new proteomic strategy based on mass spectrometry analyses of a plasma membrane fraction enriched in hydrophobic proteins. We produced from Arabidopsis cell suspensions a highly purified plasma membrane fraction and characterized it in detail by immunological and enzymatic tests. Using complementary methods for the extraction of hydrophobic proteins and mass spectrometry analyses on mono-dimensional gels, about 100 proteins have been identified, 95% of which had never been found in previous proteomic studies. The inventory of the plasma membrane proteome generated by this approach contains numerous plasma membrane integral proteins, one-third displaying at least four transmembrane segments. The plasma membrane localization was confirmed for several proteins, therefore validating such proteomic strategy. An in silico analysis shows a correlation between the putative functions of the identified proteins and the expected roles for plasma membrane in transport, signaling, cellular traffic, and metabolism. This analysis also reveals 10 proteins that display structural properties compatible with transport functions and will constitute interesting targets for further functional studies.

  20. On Floating Potential of Emissive Probes in a Partially-Magnetized Plasma

    NASA Astrophysics Data System (ADS)

    Raitses, Yevgeny; Kraus, Brian

    2016-10-01

    We compare measurements of plasma potential in a cross-field Penning discharge from two probes: swept biased Langmuir probe and floating emissive probe. The plasma potential was deduced from the first derivative of the Langmuir probe characteristic. In previous studies, the emissive and swept biased probes were placed at the channel exit of a Hall thruster (HT). Measurements showed that the emissive probe floats below the plasma potential, in agreement with conventional theories. However, recent measurements in the Penning discharge indicate a floating potential of a strongly-emitting hot probe above the plasma potential. In both probe applications, xenon plasmas have magnetized electrons and non-magnetized ions with similar plasma densities (1010 - 1011 cm-3) . Though their electron temperatures differ by an order of magnitude (Penning 5 eV, HT 50 eV), this difference cannot explain the difference in measurement values of the hot floating potential because both temperatures are much higher than the emitting wire. In this work, we investigate how the ion velocity and other plasma parameters affect this discrepancy between probe measurements of the plasma potential. This work was supported by DOE contract DE-AC02-09CH11466.

  1. Conductor analysis of the ITER FEAT poloidal field coils during a plasma scenario

    NASA Astrophysics Data System (ADS)

    Nicollet, S.; Hertout, P.; Duchateau, J. L.; Bleyer, A.; Bessette, D.

    2002-05-01

    In the framework of the ITER (International Thermonuclear Experimental Reactor) FEAT (Fusion Energy Advanced Tokamak) project, a fully superconducting PF (Poloidal Field) system has been designed in detail. The Central Solenoid and the 6 equilibrium coils constituting the PF system provide the magnetic fields which develop, shape and control the 15 MA plasma during the 1800 s of a typical plasma scenario. The 6 PF coils will be wound two-in-hand from a 45 kA niobium-titanium CICC (Cable-In-Conduit-Conductor). These coils will experience severe heat loads specially during the 400 s of the plasma burn: nuclear heating due to the 400 MW of fusion power, thermal radiation and AC losses (30 to 300 kJ). The AC losses along the PF coil pancakes are deduced from accurate magnetic field computations performed with a 3D magnetostatic code, TRAPS. The nuclear heating and the thermal radiation are assumed to be uniform over a given face of the PF coils. These heat loads are used as input to perform the thermal and hydraulic analysis with a finite element code, GANDALF. The temperature increases (0.1 to 0.4 K) are computed, the margins and performances of the conductor are evaluated.

  2. Coffee Consumption Increases the Antioxidant Capacity of Plasma and Has No Effect on the Lipid Profile or Vascular Function in Healthy Adults in a Randomized Controlled Trial.

    PubMed

    Agudelo-Ochoa, Gloria M; Pulgarín-Zapata, Isabel C; Velásquez-Rodriguez, Claudia M; Duque-Ramírez, Mauricio; Naranjo-Cano, Mauricio; Quintero-Ortiz, Mónica M; Lara-Guzmán, Oscar J; Muñoz-Durango, Katalina

    2016-03-01

    Coffee, a source of antioxidants, has controversial effects on cardiovascular health. We evaluated the bioavailability of chlorogenic acids (CGAs) in 2 coffees and the effects of their consumption on the plasma antioxidant capacity (AC), the serum lipid profile, and the vascular function in healthy adults. Thirty-eight men and 37 women with a mean ± SD age of 38.5 ± 9 y and body mass index of 24.1 ± 2.6 kg/m(2) were randomly assigned to 3 groups: a control group that did not consume coffee or a placebo and 2 groups that consumed 400 mL coffee/d for 8 wk containing a medium (MCCGA; 420 mg) or high (HCCGA; 780 mg) CGA content. Both were low in diterpenes (0.83 mg/d) and caffeine (193 mg/d). Plasma caffeic and ferulic acid concentrations were measured by GC, and the plasma AC was evaluated with use of the ferric-reducing antioxidant power method. The serum lipid profile, nitric oxide (NO) plasma metabolites, vascular endothelial function (flow-mediated dilation; FMD), and blood pressure (BP) were evaluated. After coffee consumption (1 h and 8 wk), caffeic and ferulic acid concentrations increased in the coffee-drinking groups, although the values of the 2 groups were significantly different (P < 0.001); caffeic and ferulic acid concentrations were undetectable in the control group. At 1 h after consumption, the plasma AC in the control group was significantly lower than the baseline value (-2%) and significantly increased in the MCCGA (6%) and HCCGA (5%) groups (P < 0.05). After 8 wk, no significant differences in the lipid, FMD, BP, or NO plasma metabolite values were observed between the groups. Both coffees, which contained CGAs and were low in diterpenes and caffeine, provided bioavailable CGAs and had a positive acute effect on the plasma AC in healthy adults and no effect on blood lipids or vascular function. The group that did not drink coffee showed no improvement in serum lipid profile, FMD, BP, or NO plasma metabolites. This trial was registered at

  3. AC Coupled Interconnect for Low Power Spaceborne Electronics

    DTIC Science & Technology

    2006-09-30

    Final Report 3. DATES COVERED (From - To) 20/05/2003 to 30/09/2006 4. TITLE AND SUBTITLE AC COUPLED INTERCONNECT FOR LOW POWER SPACEBORNE...14. ABSTRACT The primary objective of this effort was to establish that AC Coupled Interconnect could be used to create multiple solutions to...

  4. Megajoule Dense Plasma Focus Solid Target Experiments

    NASA Astrophysics Data System (ADS)

    Podpaly, Y. A.; Falabella, S.; Link, A.; Povilus, A.; Higginson, D. P.; Shaw, B. H.; Cooper, C. M.; Chapman, S.; Bennett, N.; Sipe, N.; Olson, R.; Schmidt, A. E.

    2016-10-01

    Dense plasma focus (DPF) devices are plasma sources that can produce significant neutron yields from beam into gas interactions. Yield increases, up to approximately a factor of five, have been observed previously on DPFs using solid targets, such as CD2 and D2O ice. In this work, we report on deuterium solid-target experiments at the Gemini DPF. A rotatable target holder and baffle arrangement were installed in the Gemini device which allowed four targets to be deployed sequentially without breaking vacuum. Solid targets of titanium deuteride were installed and systematically studied at a variety of fill pressures, bias voltages, and target positions. Target holder design, experimental results, and comparison to simulations will be presented. Prepared by LLNL under Contract DE-AC52-07NA27344.

  5. [Ru/AC catalyzed ozonation of recalcitrant organic compounds].

    PubMed

    Wang, Jian-Bing; Hou, Shao-Pei; Zhou, Yun-Rui; Zhu, Wan-Peng; He, Xu-Wen

    2009-09-15

    Ozonation and Ru/AC catalyzed ozonation of dimethyl phthalate (DMP), phenols and disinfection by-products precursors were studied. It shows that Ru/AC catalyst can obviously enhance the mineralization of organic compounds. In the degradation of DMP, TOC removal was 28.84% by ozonation alone while it was 66.13% by catalytic ozonation. In the oxidation of 23 kinds of phenols, TOC removals were 9.57%-56.08% by ozonation alone while they were 41.81%-82.32% by catalytic ozonation. Compared to ozonation alone, Ru/AC catalyzed ozonation was more effective for the reduction of disinfection by-products formation potentials in source water. The reduction of haloacetic acids formation potentials was more obvious than thichlomethane formation potentials. After the treatment by catalytic ozonation, the haloacetic acids formation potentials decreased from 144.02 microg/L to 58.50 microg/L, which was below the standard value of EPA. However ozonation alone could not make it reach the standard. The treatments of source water by BAC, O3 + BAC, O3/AC + BAC and Ru/AC + O3 + BAC were also studied. In the four processes, TOC removal was 3.80%, 20.14%, 27.45% and 48.30% respectively, COD removal was 4.37%, 27.22%, 39.91% and 50.00% respectively, UV254 removal was 8.16%, 62.24%, 67.03% and 84.95% respectively. Ru/AC + O3 + BAC process is more effective than the other processes for the removal of TOC, COD and UV254 and no ruthenium leaching observed in the solution. It is a promising process for the treatment of micro polluted source water.

  6. Methods for Addressing Missing Data with Applications from ACS Exams

    ERIC Educational Resources Information Center

    Brandriet, Alexandra; Holme, Thomas

    2015-01-01

    As part of the ACS Examinations Institute (ACS-EI) national norming process, student performance data sets are collected from professors at colleges and universities from around the United States. Because the data sets are collected on a volunteer basis, the ACS-EI often receives data sets with only students' total scores and without the students'…

  7. Examining the temperature behavior of stainless steel surfaces exposed to hydrogen plasmas in the Lithium Tokamak eXperiment (LTX)

    NASA Astrophysics Data System (ADS)

    Bedoya, Felipe; Allain, Jean Paul; Kaita, Robert; Lucia, Matthew; St-Onge, Denis; Ellis, Robert; Majeski, Richard

    2014-10-01

    The Materials Analysis Particle Probe (MAPP) is an in-situ diagnostic designed to characterize plasma-facing components (PFCs) in tokamak devices. MAPP is installed in LTX at Princeton Plasma Physics Laboratory. MAPP's capabilities include remotely operated XPS acquisition and temperature control of four samples. The recent addition of a focused ion beam allows XPS depth profiling analysis. Recent published results show an apparent correlation between hydrogen retention and temperature of Li coated stainless steel (SS) PFCs exposed to plasmas like those of LTX. According to XPS data, the retention of hydrogen by the coated surfaces decreases at above 180 °C. In the present study MAPP will be used to study the oxidation of Li coatings as a function of time and temperature of the walls when Li coatings are applied. Experiments in the ion-surface interaction experiment (IIAX) varying the hydrogen fluence on the SS samples will be also performed. Conclusions resulting from this study will be key to explain the PFC temperature-dependent variation of plasma performance observed in LTX. This work was supported by U.S. DOE Contracts DE-AC02-09CH11466, DE-AC52-07NA27344 and DE-SC0010717.

  8. The diagnosing of plasmas using spectroscopy and imaging on Proto-MPEX

    NASA Astrophysics Data System (ADS)

    Baldwin, K. A.; Biewer, T. M.; Crouse Powers, J.; Hardin, R.; Johnson, S.; McCleese, A.; Shaw, G. C.; Showers, M.; Skeen, C.

    2015-11-01

    The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device being developed at Oak Ridge National Laboratory (ORNL). This machine plans to study plasma-material interaction (PMI) physics relevant to future fusion reactors. We tested and learned to use tools of spectroscopy and imaging. These tools consist of a spectrometer, a high speed camera, an infrared camera, and a thermocouple. The spectrometer measures the color of the light from the plasma and its intensity. We also used a high speed camera to see how the magnetic field acts on the plasma, and how it is heated to the fourth state of matter. The thermocouples measure the temperature of the objects they are placed against, which in this case are the end plates of the machine. We also used the infrared camera to see the heat pattern of the plasma on the end plates. Data from these instruments will be shown. This work was supported by the US. D.O.E. contract DE-AC05-00OR22725, and the Oak Ridge Associated Universities ARC program.

  9. Experimental investigation of differential confinement effects in a rotating helicon plasma

    NASA Astrophysics Data System (ADS)

    Gueroult, Renaud; Evans, Eugene; Zweben, Stewart J.; Fisch, Nathaniel J.; Levinton, Fred

    2014-10-01

    Although plasmas have long been considered for isotope separation, challenges presented by nuclear waste remediation and nuclear spent fuel reprocessing have recently sparked a renewed interest for high-throughput plasma based mass separation techniques. Different filter concepts relying on rotating plasmas have been proposed to address these needs. However, one of the challenges common to these concepts is the need to control the plasma rotation profile, which is generally assumed to be provided by means of dedicated electrodes. An experimental effort aiming to evaluate the practicality of these plasma filter concepts has recently been started at PPPL. For this purpose, a linear helicon plasma source is used in combination with concentric ring electrodes. Preliminary biasing experiments results indicate floating potential profiles locally suitable for mass discrimination for different gas mixtures (Ar/Ne, Ar/N2, Ar/Kr). Radially resolved spectroscopic measurements and neutral gas composition analysis at two different axial positions are being planned to assess the mass separation effect. Work supported by US DOE under Contract No. DE-AC02-09CH11466.

  10. Diagnostics of the Fermilab Tevatron using an AC dipole

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miyamoto, Ryoichi

    2008-08-01

    The Fermilab Tevatron is currently the world's highest energy colliding beam facility. Its counter-rotating proton and antiproton beams collide at 2 TeV center-of-mass. Delivery of such intense beam fluxes to experiments has required improved knowledge of the Tevatron's beam optical lattice. An oscillating dipole magnet, referred to as an AC dipole, is one of such a tool to non-destructively assess the optical properties of the synchrotron. We discusses development of an AC dipole system for the Tevatron, a fast-oscillating (f ~ 20 kHz) dipole magnet which can be adiabatically turned on and off to establish sustained coherent oscillations of themore » beam particles without affecting the transverse emittance. By utilizing an existing magnet and a higher power audio amplifier, the cost of the Tevatron AC dipole system became relatively inexpensive. We discuss corrections which must be applied to the driven oscillation measurements to obtain the proper interpretation of beam optical parameters from AC dipole studies. After successful operations of the Tevatron AC dipole system, AC dipole systems, similar to that in the Tevatron, will be build for the CERN LHC. We present several measurements of linear optical parameters (beta function and phase advance) for the Tevatron, as well as studies of non-linear perturbations from sextupole and octupole elements.« less

  11. Gold Spectra Measurements from LLNL EBIT Plasmas

    NASA Astrophysics Data System (ADS)

    May, M.; Brown, G. V.; Chen, H.; Chung, H. K.; Gu, M.; Hansen, S. B.; Schneider, M. B.; Widmann, K.; Beiersdorfer, P.

    2008-11-01

    Spectra have been recorded from gold that has been injected into the Lawrence Livermore Electron Beam Ion Trap (EBIT-II). Both mono-energetic and experimentally simulated Maxwell-Boltzmann (MB) plasmas were created for these measurements. The beam plasmas had energies of 2.75, 3.0, 3.6, 4.6, 5.5, 6.0, 6.5 keV. The MB plasmas had electron temperatures of 2.0, 2.5 and 3.0 keV. M-band gold spectra (n = 4-3, 5-3, 6-3 and 7-3 transitions) were recorded between 1 - 8 keV from K-like to Kr-like ions in the x-ray. The emission of gold was recorded by crystal spectrometers and a micro-calorimeter from the Goddard Space Flight Center. A full survey of the recorded spectra will be presented along with line emission and charge state modeling from the flexible atomic code (FAC). Some comparisons with laser produced plasmas will be made. *This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  12. Diagnostics of an AC driven atmospheric pressure non-thermal plasma jet and its use for radially directed jet array

    NASA Astrophysics Data System (ADS)

    Zhu, W.; Wang, R.

    2017-08-01

    An alternating current atmospheric pressure plasma jet is generated with noble gas or noble gas/oxygen admixture as working gas. A "core plasma filament" is observed at the center of the dielectric tube and extends to the plasma jet at higher peak-to-peak voltages. This type of plasma jet is believed to be of the same nature with the reported plasma bullet driven by pulsed DC power sources. Double current probes are used to assess the speed of the plasma bullet and show that the speed is around 104-105 m/s. The time dependence of the downstream bullet speed is attributed to the gas heating and in turn the increase of the reduced electric field E/N. Optical emission spectra show the dependence of helium and oxygen emission intensities on the concentration of oxygen additive in the carrier gas, with peak values found at 0.5% O2. Multiple radial jets are realized on dielectric tubes of different sizes. As a case study, one of these multi-jet devices is used to treat B. aureus on the inner surface of a plastic beaker and is shown to be more effective than a single jet.

  13. Effect of display location on control-display stereotype strength for translational and rotational controls with linear displays.

    PubMed

    Chan, Alan H S; Hoffmann, Errol R

    2015-01-01

    Experiments were designed to investigate the effects of control type and display location, relative to the operator, on the strength of control/display stereotypes. The Worringham and Beringer Visual Field principle and an extension of this principle for rotary controls (Hoffmann E.R., and Chan A.H.S. 2013). "The Worringham and Beringer 'Visual Field' Principle for Rotary Controls. Ergonomics." 56 (10): 1620-1624) indicated that, for a number of different control types (rotary and lever) on different planes, there should be no significant effect of the display location relative to the seated operator. Past data were surveyed and stereotype strengths listed. Experiments filled gaps where data are not available. Six different control types and seven display locations were used, as in the Frame of Reference Transformation Tool (FORT) model of Wickens et al. (Wickens, C.D., Keller, J.W., and Small, R.L. (2010). "Left. No, Right! Development of the Frame of Reference Transformation Tool (FORT)." Proceedings of the Human Factors and Ergonomics Society 54th Annual Meeting September 2010, 54: 1022-1026). Control/display arrangements with high stereotype strengths were evaluated yielding data for designers of complex control/display arrangements where the control and display are in different planes and for where the operator is moving. It was found possible to predict display/control arrangements with high stereotype strength, based on past data. Practitioner Summary: Controls and displays in complex arrangements need to have high compatibility. These experiments provide arrangements for six different controls (rotary and translational) and seven different display locations relative to the operator.

  14. DC and AC Electric Field Measurements by Spin-Plane Double Probes Onboard MMS

    NASA Astrophysics Data System (ADS)

    Lindqvist, P. A.; Marklund, G. T.; Khotyaintsev, Y. V.; Ergun, R. E.; Goodrich, K.; Torbert, R. B.; Argall, M. R.; Nakamura, R.

    2015-12-01

    The four spacecraft of the NASA Magnetospheric Multiscale mission (MMS) were launched on 12 March 2015 into a 1.2 x 12 Re equatorial orbit to study energy conversion processes in Earth's magnetosphere. After a 5-month commissioning period the first scientific phase starts on 1 September as the orbit enters the dusk magnetopause region. The Spin-plane Double Probe electric field instrument (SDP), part of the electric and magnetic fields instrument suite FIELDS, measures the electric field in the range 0.3 - 500 mV/m with a continuous time resolution up to 8192 samples/s. The instrument features adjustable bias currents and guard voltages to optimize the measurement performance. SDP also measures the spacecraft potential, which can be controlled by the Active Spacecraft Potential Control (ASPOC) ion emitter, and under certain conditions can be used to determine plasma density. We present observations of DC and AC electric fields in different plasma regions covered by MMS since launch including the night side flow braking region, reconnection regions at the dusk and dayside magnetopause, and in the magnetosheath. We compare the electric field measurements by SDP to other, independent determinations of the electric field, in particular by the Electron Drift Instrument (EDI), in order to assess the accuracy of the electric field measurement under different plasma conditions. We also study the influence of the currents emitted by ASPOC and EDI on the SDP measurements.

  15. Aragonite coating solutions (ACS) based on artificial seawater

    NASA Astrophysics Data System (ADS)

    Tas, A. Cuneyt

    2015-03-01

    Aragonite (CaCO3, calcium carbonate) is an abundant biomaterial of marine life. It is the dominant inorganic phase of coral reefs, mollusc bivalve shells and the stalactites or stalagmites of geological sediments. Inorganic and initially precipitate-free aragonite coating solutions (ACS) of pH 7.4 were developed in this study to deposit monolayers of aragonite spherules or ooids on biomaterial (e.g., UHMWPE, ultrahigh molecular weight polyethylene) surfaces soaked in ACS at 30 °C. The ACS solutions of this study have been developed for the surface engineering of synthetic biomaterials. The abiotic ACS solutions, enriched with calcium and bicarbonate ions at different concentrations, essentially mimicked the artificial seawater composition and started to deposit aragonite after a long (4 h) incubation period at the tropical sea surface temperature of 30 °C. While numerous techniques for the solution deposition of calcium hydroxyapatite (Ca10(PO4)6(OH)2), of low thermodynamic solubility, on synthetic biomaterials have been demonstrated, procedures related to the solution-based surface deposition of high solubility aragonite remained uncommon. Monolayers of aragonite ooids deposited at 30 °C on UHMWPE substrates soaked in organic-free ACS solutions were found to possess nano-structures similar to the mortar-and-brick-type botryoids observed in biogenic marine shells. Samples were characterized using SEM, XRD, FTIR, ICP-AES and contact angle goniometry.

  16. ac electroosmotic pumping induced by noncontact external electrodes

    PubMed Central

    Wang, Shau-Chun; Chen, Hsiao-Ping; Chang, Hsueh-Chia

    2007-01-01

    Electroosmotic (EO) pumps based on dc electroosmosis is plagued by bubble generation and other electrochemical reactions at the electrodes at voltages beyond 1 V for electrolytes. These disadvantages limit their throughput and offset their portability advantage over mechanical syringe or pneumatic pumps. ac electroosmotic pumps at high frequency (>100 kHz) circumvent the bubble problem by inducing polarization and slip velocity on embedded electrodes,1 but they require complex electrode designs to produce a net flow. We report a new high-throughput ac EO pump design based on induced-polarization on the entire channel surface instead of just on the electrodes. Like dc EO pumps, our pump electrodes are outside of the load section and form a cm-long pump unit consisting of three circular reservoirs (3 mm in diameter) connected by a 1×1 mm channel. The field-induced polarization can produce an effective Zeta potential exceeding 1 V and an ac slip velocity estimated as 1 mm∕sec or higher, both one order of magnitude higher than earlier dc and ac pumps, giving rise to a maximum throughput of 1 μl∕sec. Polarization over the entire channel surface, quadratic scaling with respect to the field and high voltage at high frequency without electrode bubble generation are the reasons why the current pump is superior to earlier dc and ac EO pumps. PMID:19693362

  17. ac electroosmotic pumping induced by noncontact external electrodes.

    PubMed

    Wang, Shau-Chun; Chen, Hsiao-Ping; Chang, Hsueh-Chia

    2007-09-21

    Electroosmotic (EO) pumps based on dc electroosmosis is plagued by bubble generation and other electrochemical reactions at the electrodes at voltages beyond 1 V for electrolytes. These disadvantages limit their throughput and offset their portability advantage over mechanical syringe or pneumatic pumps. ac electroosmotic pumps at high frequency (>100 kHz) circumvent the bubble problem by inducing polarization and slip velocity on embedded electrodes,1 but they require complex electrode designs to produce a net flow. We report a new high-throughput ac EO pump design based on induced-polarization on the entire channel surface instead of just on the electrodes. Like dc EO pumps, our pump electrodes are outside of the load section and form a cm-long pump unit consisting of three circular reservoirs (3 mm in diameter) connected by a 1x1 mm channel. The field-induced polarization can produce an effective Zeta potential exceeding 1 V and an ac slip velocity estimated as 1 mmsec or higher, both one order of magnitude higher than earlier dc and ac pumps, giving rise to a maximum throughput of 1 mulsec. Polarization over the entire channel surface, quadratic scaling with respect to the field and high voltage at high frequency without electrode bubble generation are the reasons why the current pump is superior to earlier dc and ac EO pumps.

  18. Direct-current cathodic vacuum arc system with magnetic-field mechanism for plasma stabilization.

    PubMed

    Zhang, H-S; Komvopoulos, K

    2008-07-01

    Filtered cathodic vacuum arc (FCVA) deposition is characterized by plasma beam directionality, plasma energy adjustment via substrate biasing, macroparticle filtering, and independent substrate temperature control. Between the two modes of FCVA deposition, namely, direct current (dc) and pulsed arc, the dc mode yields higher deposition rates than the pulsed mode. However, maintaining the dc arc discharge is challenging because of its inherent plasma instabilities. A system generating a special configuration of magnetic field that stabilizes the dc arc discharge during film deposition is presented. This magnetic field is also part of the out-of-plane magnetic filter used to focus the plasma beam and prevent macroparticle film contamination. The efficiency of the plasma-stabilizing magnetic-field mechanism is demonstrated by the deposition of amorphous carbon (a-C) films exhibiting significantly high hardness and tetrahedral carbon hybridization (sp3) contents higher than 70%. Such high-quality films cannot be produced by dc arc deposition without the plasma-stabilizing mechanism presented in this study.

  19. Electron Energy Distribution function in a weakly magnetized expanding helicon plasma discharge

    NASA Astrophysics Data System (ADS)

    Sirse, Nishant; Harvey, Cleo; Gaman, Cezar; Ellingboe, Bert

    2016-09-01

    Helicon wave heating is well known to produce high-density plasma source for application in plasma thrusters, plasma processing and many more. Our previous study (B Ellingboe et al. APS Gaseous Electronics Conference 2015, abstract #KW2.005) has shown observation of helicon wave in a weakly magnetized inductively coupled plasma source excited by m =0 antenna at 13.56 MHz. In this paper, we investigated the Electron Energy Distribution Function (EEDF) in the same setup by using an RF compensated Langmuir probe. The ac signal superimposition technique (second harmonic technique) is used to determine EEDF. The EEDF is measured for 5-100 mTorr gas pressure, 100 W - 1.5 kW rf power and at different locations in the source chamber, boundary and diffusion chamber. This paper will discuss the change in the shape of EEDF for various heating mode transitions.

  20. ac propulsion system for an electric vehicle

    NASA Technical Reports Server (NTRS)

    Geppert, S.

    1980-01-01

    It is pointed out that dc drives will be the logical choice for current production electric vehicles (EV). However, by the mid-80's, there is a good chance that the price and reliability of suitable high-power semiconductors will allow for a competitive ac system. The driving force behind the ac approach is the induction motor, which has specific advantages relative to a dc shunt or series traction motor. These advantages would be an important factor in the case of a vehicle for which low maintenance characteristics are of primary importance. A description of an EV ac propulsion system is provided, taking into account the logic controller, the inverter, the motor, and a two-speed transmission-differential-axle assembly. The main barrier to the employment of the considered propulsion system in EV is not any technical problem, but inverter transistor cost.

  1. Plasma disturbances observed in the ionosphere in the vicinity of a highly charged space vehicle

    NASA Astrophysics Data System (ADS)

    Maehlum, B. N.; Denig, W. F.; Friedrich, M.; Torkar, K. M.; Svenes, K.; Maynard, N. C.; Trøim, J.; Holmgren, G.; Burke, W. J.

    A mother-daughter rocket code named Maimik was launched from Andoya Rocket Range on November 10, 1985, near 20.00 local time. The daughter carried an electron accelerator, and a series of plasma diagnostic instruments were installed both on the daughter and on the trailing mother. The main aims of the experiment were to investigate (1) beam-plasma interaction processes in the ionosphere, (2) occurrence of dc and ac electric fields generated by the beam and (3) charging and neutralization of the vehicles.

  2. Gageostatins A-C, antimicrobial linear lipopeptides from a marine Bacillus subtilis.

    PubMed

    Tareq, Fakir Shahidullah; Lee, Min Ah; Lee, Hyi-Seung; Lee, Jong-Seok; Lee, Yeon-Ju; Shin, Hee Jae

    2014-01-31

    Concerning the requirements of effective drug candidates to combat against high rising multidrug resistant pathogens, we isolated three new linear lipopeptides, gageostatins A-C (1-3), consisting of hepta-peptides and new 3-β-hydroxy fatty acids from the fermentation broth of a marine-derived bacterium Bacillus subtilis. Their structures were elucidated by analyzing a combination of extensive 1D, 2D NMR spectroscopic data and high resolution ESIMS data. Fatty acids, namely 3-β-hydroxy-11-methyltridecanoic and 3-β-hydroxy-9,11-dimethyltridecanoic acids were characterized in lipopeptides 1 and 2, respectively, whereas an unsaturated fatty acid (E)-7,9-dimethylundec-2-enoic acid was assigned in 3. The 3R configuration of the stereocenter of 3-β-hydroxy fatty acids in 1 and 2 was established by Mosher's MTPA method. The absolute stereochemistry of amino acid residues in 1-3 was ascertained by acid hydrolysis followed by Marfey's derivatization studies. Gageostatins 1-3 exhibited good antifungal activities with MICs values of 4-32 µg/mL when tested against pathogenic fungi (R. solani, B. cinerea and C. acutatum) and moderate antibacterial activity against bacteria (B. subtilis, S. aeureus, S. typhi and P. aeruginosa) with MICs values of 8-64 µg/mL. Futhermore, gageostatins 1-3 displayed cytotoxicity against six human cancer cell lines with GI₅₀ values of 4.6-19.6 µg/mL. It is also noteworthy that mixed compounds 1+2 displayed better antifungal and cytotoxic activities than individuals.

  3. Monocular display unit for 3D display with correct depth perception

    NASA Astrophysics Data System (ADS)

    Sakamoto, Kunio; Hosomi, Takashi

    2009-11-01

    A study of virtual-reality system has been popular and its technology has been applied to medical engineering, educational engineering, a CAD/CAM system and so on. The 3D imaging display system has two types in the presentation method; one is a 3-D display system using a special glasses and the other is the monitor system requiring no special glasses. A liquid crystal display (LCD) recently comes into common use. It is possible for this display unit to provide the same size of displaying area as the image screen on the panel. A display system requiring no special glasses is useful for a 3D TV monitor, but this system has demerit such that the size of a monitor restricts the visual field for displaying images. Thus the conventional display can show only one screen, but it is impossible to enlarge the size of a screen, for example twice. To enlarge the display area, the authors have developed an enlarging method of display area using a mirror. Our extension method enables the observers to show the virtual image plane and to enlarge a screen area twice. In the developed display unit, we made use of an image separating technique using polarized glasses, a parallax barrier or a lenticular lens screen for 3D imaging. The mirror can generate the virtual image plane and it enlarges a screen area twice. Meanwhile the 3D display system using special glasses can also display virtual images over a wide area. In this paper, we present a monocular 3D vision system with accommodation mechanism, which is useful function for perceiving depth.

  4. Modeling and Correcting the Time-Dependent ACS PSF

    NASA Technical Reports Server (NTRS)

    Rhodes, Jason; Massey, Richard; Albert, Justin; Taylor, James E.; Koekemoer, Anton M.; Leauthaud, Alexie

    2006-01-01

    The ability to accurately measure the shapes of faint objects in images taken with the Advanced Camera for Surveys (ACS) on the Hubble Space Telescope (HST) depends upon detailed knowledge of the Point Spread Function (PSF). We show that thermal fluctuations cause the PSF of the ACS Wide Field Camera (WFC) to vary over time. We describe a modified version of the TinyTim PSF modeling software to create artificial grids of stars across the ACS field of view at a range of telescope focus values. These models closely resemble the stars in real ACS images. Using 10 bright stars in a real image, we have been able to measure HST s apparent focus at the time of the exposure. TinyTim can then be used to model the PSF at any position on the ACS field of view. This obviates the need for images of dense stellar fields at different focus values, or interpolation between the few observed stars. We show that residual differences between our TinyTim models and real data are likely due to the effects of Charge Transfer Efficiency (CTE) degradation. Furthermore, we discuss stochastic noise that is added to the shape of point sources when distortion is removed, and we present MultiDrizzle parameters that are optimal for weak lensing science. Specifically, we find that reducing the MultiDrizzle output pixel scale and choosing a Gaussian kernel significantly stabilizes the resulting PSF after image combination, while still eliminating cosmic rays/bad pixels, and correcting the large geometric distortion in the ACS. We discuss future plans, which include more detailed study of the effects of CTE degradation on object shapes and releasing our TinyTim models to the astronomical community.

  5. AC conductivity of a quantum Hall line junction

    NASA Astrophysics Data System (ADS)

    Agarwal, Amit; Sen, Diptiman

    2009-09-01

    We present a microscopic model for calculating the AC conductivity of a finite length line junction made up of two counter- or co-propagating single mode quantum Hall edges with possibly different filling fractions. The effect of density-density interactions and a local tunneling conductance (σ) between the two edges is considered. Assuming that σ is independent of the frequency ω, we derive expressions for the AC conductivity as a function of ω, the length of the line junction and other parameters of the system. We reproduce the results of Sen and Agarwal (2008 Phys. Rev. B 78 085430) in the DC limit (\\omega \\to 0 ), and generalize those results for an interacting system. As a function of ω, the AC conductivity shows significant oscillations if σ is small; the oscillations become less prominent as σ increases. A renormalization group analysis shows that the system may be in a metallic or an insulating phase depending on the strength of the interactions. We discuss the experimental implications of this for the behavior of the AC conductivity at low temperatures.

  6. Overview of plasma technology used in medicine

    NASA Astrophysics Data System (ADS)

    Ryan, Thomas P.; Stalder, Kenneth R.; Woloszko, Jean

    2013-02-01

    Plasma Medicine is a growing field that is having an impact in several important areas in therapeutic patient care, combining plasma physics, biology, and clinical medicine. Historically, plasmas in medicine were used in electrosurgery for cautery and non-contact hemostasis. Presently, non-thermal plasmas have attained widespread use in medicine due to their effectiveness and compatibility with biological systems. The paper will give a general overview of how low temperature, non-equilibrium, gas plasmas operate, both from physics and biology perspectives. Plasma is commonly described as the fourth state of matter and is typically comprised of charged species, active molecules and atoms, as well as a source of UV and photons. The most active areas of plasma technology applications are in wound treatment; tissue regeneration; inactivation of pathogens, including biofilms; treating skin diseases; and sterilization. There are several means of generating plasmas for use in medical applications, including plasma jets, dielectric barrier discharges, capacitively or inductively coupled discharges, or microplasmas. These systems overcome the former constraints of high vacuum, high power requirements and bulky systems, into systems that use room air and other gases and liquids at low temperature, low power, and hand-held operation at atmospheric pressure. Systems will be discussed using a variety of energy sources: pulsed DC, AC, microwave and radiofrequency, as well as the range of frequency, pulse duration, and gas combinations in an air environment. The ionic clouds and reactive species will be covered in terms of effects on biological systems. Lastly, several commercial products will be overviewed in light of the technology utilized, health care problems being solved, and clinical trial results.

  7. AC propulsion system for an electric vehicle, phase 2

    NASA Astrophysics Data System (ADS)

    Slicker, J. M.

    1983-06-01

    A second-generation prototype ac propulsion system for a passenger electric vehicle was designed, fabricated, tested, installed in a modified Mercury Lynx vehicle and track tested at the Contractor's site. The system consisted of a Phase 2, 18.7 kw rated ac induction traction motor, a 192-volt, battery powered, pulse-width-modulated, transistorized inverter packaged for under rear seat installation, a 2-axis, 2-speed, automatically-shifted mechanical transaxle and a microprocessor-based powertrain/vehicle controller. A diagnostics computer to assist tuning and fault finding was fabricated. Dc-to-mechanical-system efficiency varied from 78% to 82% as axle speed/torque ranged from 159 rpm/788 nm to 65 rpm/328 nm. Track test efficiency results suggest that the ac system will be equal or superior to dc systems when driving urban cycles. Additional short-term work is being performed under a third contract phase (AC-3) to raise transaxle efficiency to predicted levels, and to improve starting and shifting characteristics. However, the long-term challenge to the system's viability remains inverter cost. A final report on the Phase 2 system, describing Phase 3 modifications, will be issued at the conclusion of AC-3.

  8. AC propulsion system for an electric vehicle, phase 2

    NASA Technical Reports Server (NTRS)

    Slicker, J. M.

    1983-01-01

    A second-generation prototype ac propulsion system for a passenger electric vehicle was designed, fabricated, tested, installed in a modified Mercury Lynx vehicle and track tested at the Contractor's site. The system consisted of a Phase 2, 18.7 kw rated ac induction traction motor, a 192-volt, battery powered, pulse-width-modulated, transistorized inverter packaged for under rear seat installation, a 2-axis, 2-speed, automatically-shifted mechanical transaxle and a microprocessor-based powertrain/vehicle controller. A diagnostics computer to assist tuning and fault finding was fabricated. Dc-to-mechanical-system efficiency varied from 78% to 82% as axle speed/torque ranged from 159 rpm/788 nm to 65 rpm/328 nm. Track test efficiency results suggest that the ac system will be equal or superior to dc systems when driving urban cycles. Additional short-term work is being performed under a third contract phase (AC-3) to raise transaxle efficiency to predicted levels, and to improve starting and shifting characteristics. However, the long-term challenge to the system's viability remains inverter cost. A final report on the Phase 2 system, describing Phase 3 modifications, will be issued at the conclusion of AC-3.

  9. Probable alpha and 14C cluster emission from hyper Ac nuclei

    NASA Astrophysics Data System (ADS)

    Santhosh, K. P.

    2013-10-01

    A systematic study on the probability for the emission of 4He and 14C cluster from hyper {Λ/207-234}Ac and non-strange normal 207-234Ac nuclei are performed for the first time using our fission model, the Coulomb and proximity potential model (CPPM). The predicted half lives show that hyper {Λ/207-234}Ac nuclei are unstable against 4He emission and 14C emission from hyper {Λ/217-228}Ac are favorable for measurement. Our study also show that hyper {Λ/207-234}Ac are stable against hyper {Λ/4}He and {Λ/14}C emission. The role of neutron shell closure ( N = 126) in hyper {Λ/214}Fr daughter and role of proton/neutron shell closure ( Z ≈ 82, N = 126) in hyper {Λ/210}Bi daughter are also revealed. As hyper-nuclei decays to normal nuclei by mesonic/non-mesonic decay and since most of the predicted half lives for 4He and 14C emission from normal Ac nuclei are favourable for measurement, we presume that alpha and 14C cluster emission from hyper Ac nuclei can be detected in laboratory in a cascade (two-step) process.

  10. Micro-hole array fluorescent sensor based on AC-Dielectrophoresis (DEP) for simultaneous analysis of nano-molecules

    NASA Astrophysics Data System (ADS)

    Kim, Hye Jin; Kang, Dong-Hoon; Lee, Eunji; Hwang, Kyo Seon; Shin, Hyun-Joon; Kim, Jinsik

    2018-02-01

    We propose a simple fluorescent bio-chip based on two types of alternative current-dielectrophoretic (AC-DEP) force, attractive (positive DEP) and repulsive (negative DEP) force, for simultaneous nano-molecules analysis. Various radius of micro-holes on the bio-chip are designed to apply the different AC-DEP forces, and the nano-molecules are concentrated inside the micro-hole arrays according to the intensity of the DEP force. The bio-chip was fabricated by Micro Electro Mechanical system (MEMS) technique, and was composed of two layers; a SiO2 layer and Ta/Pt layer were accomplished for an insulation layer and a top electrode with micro-hole arrays to apply electric fields for DEP force, respectively. Each SiO2 and Ta/Pt layers were deposited by thermal oxidation and sputtering, and micro-hole arrays were fabricated with Inductively Coupled Plasma (ICP) etching process. For generation of each positive and negative DEP at micro-holes, we applied two types of sine-wave AC voltage with different frequency range alternately. The intensity of the DEP force was controlled by the radius of the micro-hole and size of nano-molecule, and calculated with COMSOL multi-physics. Three types of nano-molecules labelled with different fluorescent dye were used and the intensity of nano-molecules was examined by the fluorescent optical analysis after applying the DEP force. By analyzing the fluorescent intensities of the nano-molecules, we verify the various nano-molecules in analyte are located successfully inside corresponding micro-holes with different radius according to their size.

  11. Ticagrelor Compared with Clopidogrel Increased Adenosine and Cyclic Adenosine Monophosphate Plasma Concentration in Acute Coronary Syndrome Patients.

    PubMed

    Li, Xiaoye; Wang, Qibing; Xue, Ying; Chen, Jiahui; Lv, Qianzhou

    2017-06-01

    Ticagrelor produces a more potent antiplatelet effect than clopidogrel and inhibits cellular uptake of adenosine, which is associated with several cardiovascular consequences. We aimed to explore the correlation between adenosine and cyclic adenosine monophosphate (cAMP) plasma concentration and antiplatelet effect by clopidogrel or ticagrelor in patients with acute coronary syndrome (ACS) receiving dual antiplatelet therapy (DAPT). We conducted a prospective, observational and single-centre cohort study enrolling 68 patients with non-ST-segment elevation ACS from January 2016 to May 2016. We monitored the inhibition of platelet aggregation (IPA) and assessed adenosine, adenosine deaminase (ADA) and cAMP plasma concentrations by immunoassay on admission and 48 hr after coronary angiography. The demographic and clinical data were collected by reviewing their medical records. The two groups exhibited similar baseline characteristics including adenosine, ADA and cAMP. The mean IPA in patients receiving ticagrelor was significantly higher than that in patients receiving clopidogrel (93.5% versus 67.2%; p = 0.000). Also, we observed that patients treated with ticagrelor had a significantly higher increase in levels of adenosine and cAMP compared with those treated with clopidogrel (1.04 (0.86; 1.41) versus 0.04 (-0.25; 0.26); p = 0.029 and 0.78 (-1.67; 1.81) versus 0.60 (-1.91; 4.60); p = 0.037, respectively). And there was a weak correlation between IPA and adenosine as well as cAMP plasma concentration (r = 0.390, p = 0.001 and r = 0.335, p = 0.005, respectively). Ticagrelor increased adenosine and cAMP plasma concentration compared with clopidogrel in patients with ACS. © 2017 The Authors. Basic & Clinical Pharmacology & Toxicology published by John Wiley & Sons Ltd on behalf of Nordic Association for the Publication of BCPT (former Nordic Pharmacological Society).

  12. Arthroscopically Assisted Reconstruction of Acute Acromioclavicular Joint Dislocations: Anatomic AC Ligament Reconstruction With Protective Internal Bracing—The “AC-RecoBridge” Technique

    PubMed Central

    Izadpanah, Kaywan; Jaeger, Martin; Ogon, Peter; Südkamp, Norbert P.; Maier, Dirk

    2015-01-01

    An arthroscopically assisted technique for the treatment of acute acromioclavicular joint dislocations is presented. This pathology-based procedure aims to achieve anatomic healing of both the acromioclavicular ligament complex (ACLC) and the coracoclavicular ligaments. First, the acromioclavicular joint is reduced anatomically under macroscopic and radiologic control and temporarily transfixed with a K-wire. A single-channel technique using 2 suture tapes provides secure coracoclavicular stabilization. The key step of the procedure consists of the anatomic repair of the ACLC (“AC-Reco”). Basically, we have observed 4 patterns of injury: clavicular-sided, acromial-sided, oblique, and midportion tears. Direct and/or transosseous ACLC repair is performed accordingly. Then, an X-configured acromioclavicular suture tape cerclage (“AC-Bridge”) is applied under arthroscopic assistance to limit horizontal clavicular translation to a physiological extent. The AC-Bridge follows the principle of internal bracing and protects healing of the ACLC repair. The AC-Bridge is tightened on top of the repair, creating an additional suture-bridge effect and promoting anatomic ACLC healing. We refer to this combined technique of anatomic ACLC repair and protective internal bracing as the “AC-RecoBridge.” A detailed stepwise description of the surgical technique, including indications, technical pearls and pitfalls, and potential complications, is given. PMID:26052493

  13. Experiments on Alfv'en waves in high beta plasmas

    NASA Astrophysics Data System (ADS)

    Gekelman, Walter; Pribyl, Patrick; Cooper, Chris; Vincena, Stephen

    2008-11-01

    The propagation of Alfv'en waves in high beta plasmas is of great interest in solar wind studies as well as in astrophysical plasmas. Alfv'en wave propagation in a high beta plasma is studied on the axis of a toroidal device at UCLA. The vacuum vessel is 30 meters in circumference, 2 meters wide and 3 meters tall. The plasma has a cross sectional area of 20 cm^2 and can be as long as 120 m which is hundreds of parallel Alfv'en wavelengths. The waves are launched using two orthogonal 5-turn , 5.7 cm diameter loops. The AC currents (10 kHz < f < 250 kHz) to the loops are as high as 2 kA p-p, producing fields of 1 kG on the axis of the antenna. The antenna coils are independently driven such that waves with arbitrary polarization can be launched. Movable three axis magnetic pickup loops detect the wave and are used to construct field maps in the machine. Wave propagation results as a function of plasma beta and input wave energy will be presented.

  14. Edge-relevant plasma simulations with the continuum code COGENT

    NASA Astrophysics Data System (ADS)

    Dorf, M.; Dorr, M.; Ghosh, D.; Hittinger, J.; Rognlien, T.; Cohen, R.; Lee, W.; Schwartz, P.

    2016-10-01

    We describe recent advances in cross-separatrix and other edge-relevant plasma simulations with COGENT, a continuum gyro-kinetic code being developed by the Edge Simulation Laboratory (ESL) collaboration. The distinguishing feature of the COGENT code is its high-order finite-volume discretization methods, which employ arbitrary mapped multiblock grid technology (nearly field-aligned on blocks) to handle the complexity of tokamak divertor geometry with high accuracy. This paper discusses the 4D (axisymmetric) electrostatic version of the code, and the presented topics include: (a) initial simulations with kinetic electrons and development of reduced fluid models; (b) development and application of implicit-explicit (IMEX) time integration schemes; and (c) conservative modeling of drift-waves and the universal instability. Work performed for USDOE, at LLNL under contract DE-AC52-07NA27344 and at LBNL under contract DE-AC02-05CH11231.

  15. Mathematical model for the dc-ac inverter for the Space Shuttle

    NASA Technical Reports Server (NTRS)

    Berry, Frederick C.

    1987-01-01

    The reader is informed of what was done for the mathematical modeling of the dc-ac inverter for the Space Shuttle. The mathematical modeling of the dc-ac inverter is an essential element in the modeling of the electrical power distribution system of the Space Shuttle. The electrical power distribution system which is present on the Space Shuttle is made up to 3 strings each having a fuel cell which provides dc to those systems which require dc, and the inverters which convert the dc to ac for those elements which require ac. The inverters are units which are 2 wire structures for the main dc inputs and 2 wire structures for the ac output. When 3 are connected together a 4 wire wye connection results on the ac side. The method of modeling is performed by using a Least Squares curve fitting method. A computer program is presented for implementation of the model along with graphs and tables to demonstrate the accuracy of the model.

  16. [Expression of AC133 vs. CD34 in acute childhood leukemias].

    PubMed

    Ebener, U; Brinkmann, A; Zotova, V; Niegemann, E; Wehner, S

    2000-01-01

    AC133, a newly discovered antigen on human progenitor cells, demonstrating 5-transmembranous domains is expressed by 30-60% out of all CD34+ cells. Our aim therefore was to investigate the extent of human stem-/progenitor cells expressing AC133 antigen in umbilical cord blood, peripheral blood without or following an application of granulocyte-colony stimulating factor (rhG-CSF). The main task was the investigation of bone marrow aspirates derived from children suffering from newly diagnosed acute leukemias, as well as from patients with a relapse or during a complete remission. The determination of antigen expression was done by application of flow cytometry (FACScan analysis) and the usage of newly developed monoclonal antibodies (AC133/1 and AC133/2; Miltenyi Biotec GmbH) in combination with monoclonal antibody directed against CD34-antigens (HPCA-2; BD). Our studies till now show average percentages in umbilical cord blood derived from 43 newborns about 0.294 +/- 0.165% AC133+ vs. 0.327 +/- 0.156% CD34+ hematopoietic stem-/progenitor cells (HSPC). In peripheral blood from 11 healthy donors we verified up to 0.15% CD34+ as well as AC133+ HSPC's. The concentration of progenitor cells was found to be obviously higher in peripheral blood from children with various diseases (neuroblastoma, rhabdomyosarcoma, ALL/AML) and undergoing application with rhG-CSF in order to be prepared for PBSC-transplantation. In those cases we found up to 3.51% AC133+ cells as well as slightly higher values (3.94%) for CD34 antigens. Additionally we quantified 128 bone marrow (BM) samples for AC133+ and CD34+ cells. In 10 BM samples, derived from patients without any neoplasia, the CD34+ cells were about 0.03% and 1.49%, whereas AC133 values were up to 0.64%. Bone marrow aspirates from 53 children with acute leukemias at time of diagnosis (ALL: n = 41/AML: n = 12) have been immunophenotyped and leukemic blast cells have been proved for AC133- and CD34 antigen expression. 32/41 (78%) of

  17. The Macrophage Activation Induced by Bacillus thuringiensis Cry1Ac Protoxin Involves ERK1/2 and p38 Pathways and the Interaction with Cell-Surface-HSP70.

    PubMed

    Rubio-Infante, Nestor; Ilhuicatzi-Alvarado, Damaris; Torres-Martínez, Marilu; Reyes-Grajeda, Juan Pablo; Nava-Acosta, Raúl; González-González, Edith; Moreno-Fierros, Leticia

    2018-01-01

    Here, we aimed to further characterize the mechanisms involved in protoxin (p) Cry1Ac-induced macrophage activation. We demonstrated that pCry1Ac induces MAPK ERK1/2, p38, and JNK phosphorylation in RAW264.7 macrophages. Because MAPK activation is mainly triggered via ligand-receptor interactions, we focused on the identification of potential pCry1Ac-receptor proteins. Flow cytometry and confocal analysis showed specific saturable pCry1Ac-binding to the macrophage surface and evidenced its internalization via the clathrin-pathway. We performed immunoprecipitation assays and identified by MALDI-TOF-TOF several possible pCry1Ac-binding proteins, such as heat shock proteins (HSPs), vimentin, α-enolase, and actin; whose interaction and presence was confirmed, respectively, by ligand blot and Western blot assays. We also detected cell-surface (cs) pCry1Ac-HSP70 colocalization, so HSP70 was chosen for further characterization. Co-immunoprecipitation with HSP70 antibodies followed by Western blot confirmed the pCry1Ac-HSP70 interaction. Furthermore, pretreatment of RAW264.7 cells with HSP70 antibodies reduced pCry1Ac-induced ERK1 phosphorylation and MCP-1 production; thus suggest the functional participation of csHSP70 in pCry1Ac-induced macrophage activation. csHSP70 also was evaluated in peritoneal-cavity (PerC) macrophages of untreated BALB/c mice, interestingly it was found that the predominant population namely large-peritoneal-macrophages (LPM) displayed csHSP70 + hi. Furthermore, the dynamics of PerC macrophage subsets, LPM, and small-peritoneal macrophages (SPM) were evaluated in response to in vivo pCry1Ac stimuli in presence or not of phenylethynesulfonamide (PES) a functional HSP70 inhibitor. It was found that pCry1Ac increased the proportion of SPM CD11b + F4/80 + lowMHCII + csHSP70 + low and markedly reduced the amount of LPM CD11b + F4/80 + hiMHCII-csHSP70 + hi; while PES, partially suppressed this pCry1Ac-induced effect

  18. Laboratory-Produced X-Ray Photoionized Plasmas for Astrophysics Exploration

    NASA Astrophysics Data System (ADS)

    Goyon, Clement; Le Pape, Sebastien; Liedahl, Duane; Ma, Tammy; Berzak-Hopkins, Laura; Reverdin, Charles; Rousseaux, Christophe; Renaudin, Patrick; Blancard, Christophe; Nottet, Edouard; Bidault, Niels; Mancini, Roberto; Koenig, Michel

    2015-11-01

    X-ray photoionized plasmas are rare in the laboratory, but of broad importance in astrophysical objects such as active galactic nuclei, x-ray binaries. Indeed, existing models are not yet able to accurately describe these plasmas where ionization is driven by radiation rather than electron collisions. Here, we describe an experiment on the LULI2000 facility whose versatility allows for measuring the X-ray absorption of the plasma while independently probing its electron density and temperature. The bright X-ray source is created by the two main beams focused inside a gold hohlraum and is used to photoionise a Neon gas jet. Then, a thin gold foil serves as a source of backlit photons for absorption spectroscopy. The transmitted spectrum through the plasma is collected by a crystal spectrometer. We will present the experimental setup used to characterize both plasma conditions and X-ray emission. Then we will show the transmitted spectra through the plasma to observe the transition from collision dominated to radiation dominated ionization and compare it to model predictions. This work was performed under the auspices of the U.S.Department of Energy by Lawrence Livermore Natl Lab under Contract No. DE-AC52-07NA27344.

  19. System and method for determining stator winding resistance in an AC motor

    DOEpatents

    Lu, Bin [Kenosha, WI; Habetler, Thomas G [Snellville, GA; Zhang, Pinjia [Atlanta, GA; Theisen, Peter J [West Bend, WI

    2011-05-31

    A system and method for determining stator winding resistance in an AC motor is disclosed. The system includes a circuit having an input connectable to an AC source and an output connectable to an input terminal of an AC motor. The circuit includes at least one contactor and at least one switch to control current flow and terminal voltages in the AC motor. The system also includes a controller connected to the circuit and configured to modify a switching time of the at least one switch to create a DC component in an output of the system corresponding to an input to the AC motor and determine a stator winding resistance of the AC motor based on the injected DC component of the voltage and current.

  20. Lamin A/C might be involved in the EMT signalling pathway.

    PubMed

    Zuo, Lingkun; Zhao, Huanying; Yang, Ronghui; Wang, Liyong; Ma, Hui; Xu, Xiaoxue; Zhou, Ping; Kong, Lu

    2018-07-15

    We have previously reported a heterogeneous expression pattern of the nuclear membrane protein lamin A/C in low- and high-Gleason score (GS) prostate cancer (PC) tissues, and we have now found that this change is not associated with LMNA mutations. This expression pattern appears to be similar to the process of epithelial to mesenchymal transition (EMT) or to that of mesenchymal to epithelial transition (MET). The role of lamin A/C in EMT or MET in PC remains unclear. Therefore, we first investigated the expression levels of and the associations between lamin A/C and several common EMT markers, such as E-cadherin, N-cadherin, β-catenin, snail, slug and vimentin in PC tissues with different GS values and in different cell lines with varying invasion abilities. Our results suggest that lamin A/C might constitute a type of epithelial marker that better signifies EMT and MET in PC tissue, since a decrease in lamin A/C expression in GS 4 + 5 cases is likely associated with the EMT process, while the re-expression of lamin A/C in GS 5 + 4 cases is likely linked with MET. The detailed GS better exhibited the changes in lamin A/C and the EMT markers examined. Lamin A/C overexpression or knockdown had an impact on EMT biomarkers in a cell model by direct regulation of β-catenin. Hence, we suggest that lamin A/C might serve as a reliable epithelial biomarker for the distinction of PC cell differentiation and might also be a fundamental factor in the occurrence of EMT or MET in PC. Copyright © 2018. Published by Elsevier B.V.

  1. Virtual acoustics displays

    NASA Astrophysics Data System (ADS)

    Wenzel, Elizabeth M.; Fisher, Scott S.; Stone, Philip K.; Foster, Scott H.

    1991-03-01

    The real time acoustic display capabilities are described which were developed for the Virtual Environment Workstation (VIEW) Project at NASA-Ames. The acoustic display is capable of generating localized acoustic cues in real time over headphones. An auditory symbology, a related collection of representational auditory 'objects' or 'icons', can be designed using ACE (Auditory Cue Editor), which links both discrete and continuously varying acoustic parameters with information or events in the display. During a given display scenario, the symbology can be dynamically coordinated in real time with 3-D visual objects, speech, and gestural displays. The types of displays feasible with the system range from simple warnings and alarms to the acoustic representation of multidimensional data or events.

  2. Virtual acoustics displays

    NASA Technical Reports Server (NTRS)

    Wenzel, Elizabeth M.; Fisher, Scott S.; Stone, Philip K.; Foster, Scott H.

    1991-01-01

    The real time acoustic display capabilities are described which were developed for the Virtual Environment Workstation (VIEW) Project at NASA-Ames. The acoustic display is capable of generating localized acoustic cues in real time over headphones. An auditory symbology, a related collection of representational auditory 'objects' or 'icons', can be designed using ACE (Auditory Cue Editor), which links both discrete and continuously varying acoustic parameters with information or events in the display. During a given display scenario, the symbology can be dynamically coordinated in real time with 3-D visual objects, speech, and gestural displays. The types of displays feasible with the system range from simple warnings and alarms to the acoustic representation of multidimensional data or events.

  3. Assembling a supercapacitor electrode with dual metal oxides and activated carbon using a liquid phase plasma.

    PubMed

    Ki, Seo Jin; Jeon, Ki-Joon; Park, Young-Kwon; Park, Hyunwoong; Jeong, Sangmin; Lee, Heon; Jung, Sang-Chul

    2017-12-01

    Developing supercapacitor electrodes at an affordable cost while improving their energy and/or power density values is still a challenging task. This study introduced a recipe which assembled a novel electrode composite using a liquid phase plasma that was applied to a reactant solution containing an activated carbon (AC) powder with dual metal precursors of iron and manganese. A comparison was made between the composites doped with single and dual metal components as well as among those synthesized under different precursor concentrations and plasma durations. The results showed that increasing the precursor concentration and plasma duration raised the content of both metal oxides in the composites, whereas the deposition conditions were more favorable to iron oxide than manganese oxide, due to its higher standard potential. The composite treated with the longest plasma duration and highest manganese concentration was superior to the others in terms of cyclic stability and equivalent series resistance. In addition, the new composite selected out of them showed better electrochemical performance than the raw AC material only and even two types of single metal-based composites, owing largely to the synergistic effect of the two metal oxides. Therefore, the proposed methodology can be used to modify existing and future composite electrodes to improve their performance with relatively cheap host and guest materials. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. The Cryogenic Anti-Coincidence detector for ATHENA X-IFU: pulse analysis of the AC-S7 single pixel prototype

    NASA Astrophysics Data System (ADS)

    D'Andrea, M.; Argan, A.; Lotti, S.; Macculi, C.; Piro, L.; Biasotti, M.; Corsini, D.; Gatti, F.; Torrioli, G.

    2016-07-01

    The ATHENA observatory is the second large-class mission in ESA Cosmic Vision 2015-2025, with a launch foreseen in 2028 towards the L2 orbit. The mission addresses the science theme "The Hot and Energetic Universe", by coupling a high-performance X-ray Telescope with two complementary focal-plane instruments. One of these is the X-ray Integral Field Unit (X-IFU): it is a TES based kilo-pixel order array able to provide spatially resolved high-resolution spectroscopy (2.5 eV at 6 keV) over a 5 arcmin FoV. The X-IFU sensitivity is degraded by the particles background expected at L2 orbit, which is induced by primary protons of both galactic and solar origin, and mostly by secondary electrons. To reduce the background level and enable the mission science goals, a Cryogenic Anticoincidence (CryoAC) detector is placed < 1 mm below the TES array. It is a 4- pixel TES based detector, with wide Silicon absorbers sensed by Ir:Au TESes. The CryoAC development schedule foresees by Q1 2017 the delivery of a Demonstration Model (DM) to the X-IFU FPA development team. The DM is a single-pixel detector that will address the final design of the CryoAC. It will verify some representative requirements at single-pixel level, especially the detector operation at 50 mK thermal bath and the threshold energy at 20 keV. To reach the final DM design we have developed and tested the AC-S7 prototype, with 1 cm2 absorber area sensed by 65 Ir TESes. Here we will discuss the pulse analysis of this detector, which has been illuminated by the 60 keV line from a 241Am source. First, we will present the analysis performed to investigate pulses timings and spectrum, and to disentangle the athermal component of the pulses from the thermal one. Furthermore, we will show the application to our dataset of an alternative method of pulse processing, based upon Principal Component Analysis (PCA). This kind of analysis allow us to recover better energy spectra than achievable with traditional methods

  5. Bcl-2△21 and Ac-DEVD-CHO Inhibit Death of Wheat Microspores

    PubMed Central

    Sinha, Rakesh K.; Pospíšil, Pavel; Maheshwari, Priti; Eudes, François

    2016-01-01

    Microspore cell death and low green plant production efficiency are an integral obstacle in the development of doubled haploid production in wheat. The aim of the current study was to determine the effect of anti-apoptotic recombinant human B-cell lymphoma-2 (Bcl-2△21) and caspase-3-inhibitor (Ac-DEVD-CHO) in microspore cell death in bread wheat cultivars AC Fielder and AC Andrew. Induction medium containing Bcl-2△21 and Ac-DEVD-CHO yielded a significantly higher number of viable microspores, embryo-like structures and total green plants in wheat cultivars AC Fielder and AC Andrew. Total peroxidase activity was lower in Bcl-2△21 treated microspore cultures at 96 h of treatment compared to control and Ac-DEVD-CHO. Electron paramagnetic resonance study of total microspore protein showed a different scavenging activity for Bcl-2△21 and Ac-DEVD-CHO. Bcl-2△21 scavenged approximately 50% hydroxyl radical (HO•) formed, whereas Ac-DEVD-CHO scavenged approximately 20% of HO•. Conversely, reduced caspase-3-like activities were detected in the presence of Bcl-2△21 and Ac-DEVD-CHO, supporting the involvement of Bcl-2△21 and Ac-DEVD-CHO in increasing microspore viability by reducing oxidative stress and caspase-3-like activity. Our results indicate that Bcl-2△21 and Ac-DEVD-CHO protects cells from cell death following different pathways. Bcl-2△21 prevents cell damage by detoxifying HO• and suppressing caspase-3-like activity, while Ac-DEVD-CHO inhibits the cell death pathways by modulating caspase-like activity. PMID:28082995

  6. Plasma microreactor in supercritical xenon and its application to diamondoid synthesis

    NASA Astrophysics Data System (ADS)

    Oshima, F.; Stauss, S.; Ishii, C.; Pai, D. Z.; Terashima, K.

    2012-10-01

    The generation of plasmas in a microreactor is demonstrated in xenon from atmospheric pressure up to supercritical conditions. Ac high voltage at a frequency of 15 kHz was applied across a 25-µm discharge gap between a tungsten wire and a fused silica micro-capillary tube in a coaxial configuration. Using this continuous flow supercritical fluid microreactor, it was possible to synthesize diamantane and other diamondoids up to nonamantane, using adamantane as a precursor and seed. It is anticipated that plasmas generated in supercritical fluid microreactors may not only allow faster fabrication of diamondoids, but also offer opportunities for the fabrication of other nanomaterials.

  7. Cascaded Quadruple Active Bridge Structures for Multilevel DC to Three-Phase AC Conversion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Brian B; Achanta, Prasanta K; Maksimovic, Dragan

    This paper introduces a multilevel architecture comprised of interconnected dc to three-phase ac converter units. To enable series connected operation, each converter unit contains a quadruple active bridge (QAB) converter that provides isolation between the dc side and each of the three ac sides. Since each converter unit transfers dc-side power as constant balanced three-phase power on the ac side, this implies instantaneous input-output power balance and allows elimination of bulk capacitive energy storage. In addition to minimizing required capacitance, the proposed approach simultaneously enables simplified dc-link controllers amenable to decentralized implementation, supports bidirectional power transfer, and exhibits a modularmore » structure to enhance scalability. Isolation provided by the QAB allows a wide range of electrical configurations among multiple units in various dc-ac, ac-dc or ac-ac applications. In this paper, the focus is on series connections on the ac side to emphasize multilevel operation, and the approach is experimentally validated in a dc-ac system containing two cascaded converter units.« less

  8. Insights into the Membrane Interactions of the Saposin-Like Proteins Na-SLP-1 and Ac-SLP-1 from Human and Dog Hookworm

    PubMed Central

    Willis, Charlene; Wang, Conan K.; Osman, Asiah; Simon, Anne; Pickering, Darren; Mulvenna, Jason; Riboldi-Tunicliffe, Alan; Jones, Malcolm K.; Loukas, Alex; Hofmann, Andreas

    2011-01-01

    Saposin-like proteins (SAPLIPs) from soil-transmitted helminths play pivotal roles in host-pathogen interactions and have a high potential as targets for vaccination against parasitic diseases. We have identified two non-orthologous SAPLIPs from human and dog hookworm, Na-SLP-1 and Ac-SLP-1, and solved their three-dimensional crystal structures. Both proteins share the property of membrane binding as monitored by liposome co-pelleting assays and monolayer adsorption. Neither SAPLIP displayed any significant haemolytic or bactericidal activity. Based on the structural information, as well as the results from monolayer adsorption, we propose models of membrane interactions for both SAPLIPs. Initial membrane contact of the monomeric Na-SLP-1 is most likely by electrostatic interactions between the membrane surface and a prominent basic surface patch. In case of the dimeric Ac-SLP-1, membrane interactions are most likely initiated by a unique tryptophan residue that has previously been implicated in membrane interactions in other SAPLIPs. PMID:21991310

  9. Insights into the membrane interactions of the saposin-like proteins Na-SLP-1 and Ac-SLP-1 from human and dog hookworm.

    PubMed

    Willis, Charlene; Wang, Conan K; Osman, Asiah; Simon, Anne; Pickering, Darren; Mulvenna, Jason; Riboldi-Tunicliffe, Alan; Jones, Malcolm K; Loukas, Alex; Hofmann, Andreas

    2011-01-01

    Saposin-like proteins (SAPLIPs) from soil-transmitted helminths play pivotal roles in host-pathogen interactions and have a high potential as targets for vaccination against parasitic diseases. We have identified two non-orthologous SAPLIPs from human and dog hookworm, Na-SLP-1 and Ac-SLP-1, and solved their three-dimensional crystal structures. Both proteins share the property of membrane binding as monitored by liposome co-pelleting assays and monolayer adsorption. Neither SAPLIP displayed any significant haemolytic or bactericidal activity. Based on the structural information, as well as the results from monolayer adsorption, we propose models of membrane interactions for both SAPLIPs. Initial membrane contact of the monomeric Na-SLP-1 is most likely by electrostatic interactions between the membrane surface and a prominent basic surface patch. In case of the dimeric Ac-SLP-1, membrane interactions are most likely initiated by a unique tryptophan residue that has previously been implicated in membrane interactions in other SAPLIPs.

  10. Non-oxidized porous silicon-based power AC switch peripheries.

    PubMed

    Menard, Samuel; Fèvre, Angélique; Valente, Damien; Billoué, Jérôme; Gautier, Gaël

    2012-10-11

    We present in this paper a novel application of porous silicon (PS) for low-power alternating current (AC) switches such as triode alternating current devices (TRIACs) frequently used to control small appliances (fridge, vacuum cleaner, washing machine, coffee makers, etc.). More precisely, it seems possible to benefit from the PS electrical insulation properties to ensure the OFF state of the device. Based on the technological aspects of the most commonly used AC switch peripheries physically responsible of the TRIAC blocking performances (leakage current and breakdown voltage), we suggest to isolate upper and lower junctions through the addition of a PS layer anodically etched from existing AC switch diffusion profiles. Then, we comment the voltage capability of practical samples emanating from the proposed architecture. Thanks to the characterization results of simple Al-PS-Si(P) structures, the experimental observations are interpreted, thus opening new outlooks in the field of AC switch peripheries.

  11. Numerical band structure calculations of plasma metamaterials

    NASA Astrophysics Data System (ADS)

    Pederson, Dylan; Kourtzanidis, Konstantinos; Raja, Laxminarayan

    2015-09-01

    Metamaterials (MM) are materials engineered to display negative macroscopic permittivity and permeability. These materials allow for designed control over electromagnetic energy flow, especially at frequencies where natural materials do not interact. Plasmas have recently found application in MM as a negative permittivity component. The permittivity of a plasma depends on its electron density, which can be controlled by an applied field. This means that plasmas can be used in MM to actively control the transmission or reflection of incident waves. This work focuses on a plasma MM geometry in which microplasmas are generated in perforations in a metal plate. We characterizethis material by its band structure, which describes its interaction with incident waves. The plasma-EM interactions are obtained by coupling Maxwell's equations to a simplified plasma momentum equation. A plasma density profile is prescribed, and its effect on the band structure is investigated. The band structure calculations are typically done for static structures, whereas our current density responds to the incident waves. The resulting band structures are compared with experimental results.

  12. The Effects of Theta and Gamma tACS on Working Memory and Electrophysiology

    PubMed Central

    Pahor, Anja; Jaušovec, Norbert

    2018-01-01

    A single blind sham-controlled study was conducted to explore the effects of theta and gamma transcranial alternating current stimulation (tACS) on offline performance on working memory tasks. In order to systematically investigate how specific parameters of tACS affect working memory, we manipulated the frequency of stimulation (theta frequency vs. gamma frequency), the type of task (n-back vs. change detection task) and the content of the tasks (verbal vs. figural stimuli). A repeated measures design was used that consisted of three sessions: theta tACS, gamma tACS and sham tACS. In total, four experiments were conducted which differed only with respect to placement of tACS electrodes (bilateral frontal, bilateral parietal, left fronto-parietal and right-fronto parietal). Healthy female students (N = 72) were randomly assigned to one of these groups, hence we were able to assess the efficacy of theta and gamma tACS applied over different brain areas, contrasted against sham stimulation. The pre-post/sham resting electroencephalogram (EEG) analysis showed that theta tACS significantly affected theta amplitude, whereas gamma tACS had no significant effect on EEG amplitude in any of the frequency bands of interest. Gamma tACS did not significantly affect working memory performance compared to sham, and theta tACS led to inconsistent changes in performance on the n-back tasks. Active theta tACS significantly affected P3 amplitude and latency during performance on the n-back tasks in the bilateral parietal and right-fronto parietal protocols. PMID:29375347

  13. Display Techniques for Advanced Crew Stations (DTACS). Phase 1. Display Techniques Study.

    DTIC Science & Technology

    1984-03-01

    26 3.1.3 Off Screen Displays .. ................... 27 3.1.4 Flat Panel Displays. .. ................. 27 3.2 FORMAT REQUIREMENTS...Head-Up Display ....... .................... ... 96 4.5.2 Display Panel .... ................. 98 4.5.3 RGB Calligraphic Display ................ 99...117 3.4 VOICE WARNING/RESPONSE TECHNOLOGY .............. . i.117 5.5 TOUCH PANEL TECHNOLOGY ..... ................ ... 118 5.6

  14. Development of a Portable AC/DC Welding Power Supply Module

    DTIC Science & Technology

    1975-03-01

    REPORT DATE MAR 1975 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Development of a Portable AC /DC Welding Power Supply...achieved. Additional bypass capacitors were added to reduce further switch heating and voltage transients. November AC welding was achieved with...Investigate the conversion of inversion frequency back to 60 Hz for AC welding. 4) Investigate a 120V single phase mini supply. VI I Objectives A) Goals

  15. Flat-panel electronic displays: a triumph of physics, chemistry and engineering

    PubMed Central

    Hilsum, Cyril

    2010-01-01

    This paper describes the history and science behind the development of modern flat-panel displays, and assesses future trends. Electronic displays are an important feature of modern life. For many years the cathode ray tube, an engineering marvel, was universal, but its shape was cumbersome and its operating voltage too high. The need for a flat-panel display, working at a low voltage, became imperative, and much research has been applied to this need. Any versatile flat-panel display will exploit an electro-optical effect, a transparent conductor and an addressing system to deliver data locally. The first need is to convert an electrical signal into a visible change. Two methods are available, the first giving emission of light, the second modulating ambient illumination. The most useful light-emitting media are semiconductors, historically exploiting III–V or II–VI compounds, but more recently organic or polymer semiconductors. Another possible effect uses gas plasma discharges. The modulating, or subtractive, effects that have been studied include liquid crystals, electrophoresis, electrowetting and electrochromism. A transparent conductor makes it possible to apply a voltage to an extended area while observing the results. The design is a compromise, since the free electrons that carry current also absorb light. The first materials used were metals, but some semiconductors, when heavily doped, give a better balance, with high transmission for a low resistance. Delivering data unambiguously to a million or so picture elements across the display area is no easy task. The preferred solution is an amorphous silicon thin-film transistor deposited at each cross-point in an X–Y matrix. Success in these endeavours has led to many applications for flat-panel displays, including television, flexible displays, electronic paper, electronic books and advertising signs. PMID:20123746

  16. Flat-panel electronic displays: a triumph of physics, chemistry and engineering.

    PubMed

    Hilsum, Cyril

    2010-03-13

    This paper describes the history and science behind the development of modern flat-panel displays, and assesses future trends. Electronic displays are an important feature of modern life. For many years the cathode ray tube, an engineering marvel, was universal, but its shape was cumbersome and its operating voltage too high. The need for a flat-panel display, working at a low voltage, became imperative, and much research has been applied to this need. Any versatile flat-panel display will exploit an electro-optical effect, a transparent conductor and an addressing system to deliver data locally. The first need is to convert an electrical signal into a visible change. Two methods are available, the first giving emission of light, the second modulating ambient illumination. The most useful light-emitting media are semiconductors, historically exploiting III-V or II-VI compounds, but more recently organic or polymer semiconductors. Another possible effect uses gas plasma discharges. The modulating, or subtractive, effects that have been studied include liquid crystals, electrophoresis, electrowetting and electrochromism. A transparent conductor makes it possible to apply a voltage to an extended area while observing the results. The design is a compromise, since the free electrons that carry current also absorb light. The first materials used were metals, but some semiconductors, when heavily doped, give a better balance, with high transmission for a low resistance. Delivering data unambiguously to a million or so picture elements across the display area is no easy task. The preferred solution is an amorphous silicon thin-film transistor deposited at each cross-point in an X-Y matrix. Success in these endeavours has led to many applications for flat-panel displays, including television, flexible displays, electronic paper, electronic books and advertising signs.

  17. Plasma physics goes beyond fusion

    NASA Astrophysics Data System (ADS)

    Franklin, Raoul

    2008-11-01

    I was interested to read the fusion supplement published with the October issue of Physics World. However, in asserting that fusion created the need to recognize plasma physics as a separate branch of the subject, Stephen Cowley, the new director of the United Kingdom Atomic Energy Authority, was not quite correct. In fact, the word "plasma" was appropriated from the Greek by the chemical physicist (and later Nobel laureate) Irving Langmuir in 1928. It was used to describe the positive column of a gas discharge, which was then the subject of research into better lighting sources and advertising displays, as well as the underlying science.

  18. Study on AC loss measurements of HTS power cable for standardizing

    NASA Astrophysics Data System (ADS)

    Mukoyama, Shinichi; Amemiya, Naoyuki; Watanabe, Kazuo; Iijima, Yasuhiro; Mido, Nobuhiro; Masuda, Takao; Morimura, Toshiya; Oya, Masayoshi; Nakano, Tetsutaro; Yamamoto, Kiyoshi

    2017-09-01

    High-temperature superconducting power cables (HTS cables) have been developed for more than 20 years. In addition of the cable developments, the test methods of the HTS cables have been discussed and proposed in many laboratories and companies. Recently the test methods of the HTS cables is required to standardize and to common in the world. CIGRE made the working group (B1-31) for the discussion of the test methods of the HTS cables as a power cable, and published the recommendation of the test method. Additionally, IEC TC20 submitted the New Work Item Proposal (NP) based on the recommendation of CIGRE this year, IEC TC20 and IEC TC90 started the standardization work on Testing of HTS AC cables. However, the individual test method that used to measure a performance of HTS cables hasn’t been established as world’s common methods. The AC loss is one of the most important properties to disseminate low loss and economical efficient HTS cables in the world. We regard to establish the method of the AC loss measurements in rational and in high accuracy. Japan is at a leading position in the AC loss study, because Japanese researchers have studied on the AC loss technically and scientifically, and also developed the effective technologies for the AC loss reduction. The JP domestic commission of TC90 made a working team to discussion the methods of the AC loss measurements for aiming an international standard finally. This paper reports about the AC loss measurement of two type of the HTS conductors, such as a HTS conductor without a HTS shield and a HTS conductor with a HTS shield. The AC loss measurement method is suggested by the electrical method..

  19. Transgenic banana plants overexpressing a native plasma membrane aquaporin MusaPIP1;2 display high tolerance levels to different abiotic stresses.

    PubMed

    Sreedharan, Shareena; Shekhawat, Upendra K S; Ganapathi, Thumballi R

    2013-10-01

    Water transport across cellular membranes is regulated by a family of water channel proteins known as aquaporins (AQPs). As most abiotic stresses like suboptimal temperatures, drought or salinity result in cellular dehydration, it is imperative to study the cause-effect relationship between AQPs and the cellular consequences of abiotic stress stimuli. Although plant cells have a high isoform diversity of AQPs, the individual and integrated roles of individual AQPs in optimal and suboptimal physiological conditions remain unclear. Herein, we have identified a plasma membrane intrinsic protein gene (MusaPIP1;2) from banana and characterized it by overexpression in transgenic banana plants. Cellular localization assay performed using MusaPIP1;2::GFP fusion protein indicated that MusaPIP1;2 translocated to plasma membrane in transformed banana cells. Transgenic banana plants overexpressing MusaPIP1;2 constitutively displayed better abiotic stress survival characteristics. The transgenic lines had lower malondialdehyde levels, elevated proline and relative water content and higher photosynthetic efficiency as compared to equivalent controls under different abiotic stress conditions. Greenhouse-maintained hardened transgenic plants showed faster recovery towards normal growth and development after cessation of abiotic stress stimuli, thereby underlining the importance of these plants in actual environmental conditions wherein the stress stimuli is often transient but severe. Further, transgenic plants where the overexpression of MusaPIP1;2 was made conditional by tagging it with a stress-inducible native dehydrin promoter also showed similar stress tolerance characteristics in in vitro and in vivo assays. Plants developed in this study could potentially enable banana cultivation in areas where adverse environmental conditions hitherto preclude commercial banana cultivation. © 2013 Society for Experimental Biology, Association of Applied Biologists and John Wiley & Sons

  20. 40 CFR Appendixes A-C to Part 403 - [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 30 2013-07-01 2012-07-01 true [Reserved] A Appendixes A-C to Part 403 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GENERAL PRETREATMENT REGULATIONS FOR EXISTING AND NEW SOURCES OF POLLUTION Appendixes A-C to Part 403...

  1. Exenatide: AC 2993, AC002993, AC2993A, exendin 4, LY2148568.

    PubMed

    2004-01-01

    Exenatide [AC002993, AC2993A, AC 2993, LY2148568, exendin 4], a glucagon-like peptide-1 (GLP-1) agonist, is a synthetic exendin 4 compound under development with Amylin Pharmaceuticals for the treatment of type 2 diabetes. Both exendin 4 and its analogue, exendin 3, are 39-amino acid peptides isolated from Heloderma horridum lizard venom that have different amino acids at positions 2 and 3, respectively. Exendins are able to stimulate insulin secretion in response to rising blood glucose levels, and modulate gastric emptying to slow the entry of ingested sugars into the bloodstream. Amylin Pharmaceuticals acquired exclusive patent rights for the two exendin compounds (exendin 3 and exendin 4) from the originator, Dr John Eng (Bronx, NY, US). On 20 September 2002, Amylin and Eli Lilly signed a collaborative agreement for the development and commercialisation of exenatide for type 2 diabetes. Under the terms of the agreement, Eli Lilly has paid Amylin a licensing fee of 80 million US dollars and bought Amylin's stock worth 30 million US dollars at 18.69 US dollars a share. After the initial payment, Eli Lilly will pay Amylin up to 85 US dollars million upon reaching certain milestones and also make an additional payment of up to 130 million US dollars upon global commercialisation of exenatide. Both companies will share the US development and commercialisation costs, while Eli Lilly will pick up up to 80% of development costs and all commercialisation costs outside the US. Amylin and Eli Lilly will equally share profit from sales in the US, while Eli Lilly will get 80% of the profit outside the US and Amylin will get the rest. This agreement has also enabled Amylin to train its sales force to co-promote Lilly's human growth hormone Humatrope. Alkermes will receive research and development funding and milestone payments, and also a combination of royalty payments and manufacturing fees based on product sales. Alkermes undertakes the responsibility for the development

  2. Highlights of 10th plasma chemistry meeting

    NASA Technical Reports Server (NTRS)

    Kitamura, K.; Hashimoto, H.; Hozumi, K.

    1981-01-01

    The chemical structure is given of a film formed by plasma polymerization from pyridine monomers. The film has a hydrophilic chemical structure, its molecular weight is 900, and the molecular system is C55H50N10O3. The electrical characteristics of a plasma polymerized film are described. The film has good insulating properties and was successfully applied as video disc coating. Etching resistance properties make it possible to use the film as a resist in etching. The characteristics of plasma polymer formed from monomers containing tetramethyltin are discussed. The polymer is in film form, displays good adhesiveness, is similar to UV film UV 35 in light absorption and is highly insulating.

  3. Assessing the electrochemical performance of a supercapacitor electrode made of copper oxide and activated carbon using liquid phase plasma

    NASA Astrophysics Data System (ADS)

    Ki, Seo Jin; Lee, Heon; Park, Young-Kwon; Kim, Sun-Jae; An, Kay-Hyeok; Jung, Sang-Chul

    2018-07-01

    Successful modification of surface properties of a nanocomposite electrode is prerequisite to enhancing the overall performance of electrochemical supercapacitors. The present study was designed to describe the microstructural and electrochemical characteristics of a new composite electrode assembled by activated carbon (AC) powder (as a host) and copper precursor (as a guest) using liquid phase plasma. The fabrication processes were conducted by changing plasma discharge time from 30 to 90 min in the presence and absence of (thermal) oxidation. We observed that merging plasma and oxidation treatments raised the content of copper oxide nanoparticles precipitated (evenly) on the AC surface, along with oxygen. A mixed valence state of copper oxides (in the forms of Cuo, Cu2O, and CuO) was found in different composites with and without oxidation, where CuO and Cuo affected a specific capacitance in positive and negative ways, respectively. This led to the difference of electrochemical stability and resistance among the assembled composites. For instance, the best cycling performance was observed in the plasma-treated composite for 90 min with oxidation, whereas that of 60 min without oxidation recorded the lowest resistance. Therefore, a proper balance between the capacitance and resistance appears to be required for effective fabrication of the supercapacitor electrode, specifically in cases involving copper oxides.

  4. Large-aperture Tunable Plasma Meta-material to Interact with Electromagnetic Waves

    NASA Astrophysics Data System (ADS)

    Corke, Thomas; Matlis, Eric

    2016-11-01

    The formation of spatially periodic arrangements of glow discharge plasma resulting from charge instabilities were investigated as a tuneable plasma meta-material. The plasma was formed between two 2-D parallel dielectric covered electrodes: one consisting of an Indium-Tin-Oxide coated glass sheet, and the other consisting of a glass-covered circular electrode. The dielectric covered electrodes were separated by a gap that formed a 2-D channel. The gap spacing was adjustable. The electrodes were powered by a variable amplitude AC generator. The parallel electrode arrangement was placed in a variable pressure vacuum chamber. Various combinations of gap spacing, pressure and voltage resulted in the formation of spatially periodic arrangements (lattice) of glow discharge plasma. The lattice spacing perfectly followed 2-D packing theory, and was fully adjustable through the three governing parameters. Lattice arrangements were designed to interact with electromagnetic (EM) waves in the frequency range between 10GHz-80GHz. Its feasibility was investigate through an EM wave simulation that we adapted to allow for plasma permittivity. The results showed a clear suppression of the EM wave amplitude through the plasma gratings. Supported by AFOSR.

  5. Plasma-based Compressor Stall Control

    NASA Astrophysics Data System (ADS)

    McGowan, Ryan; Corke, Thomas

    2017-11-01

    The use of dielectric barrier discharge (DBD) plasma actuator casing treatment to prevent or delay stall inception in an axial fan is examined. The actuators are powered by a pulsed-DC waveform which induces a larger peak velocity than a purely AC waveform such as a sine or sawtooth wave. With this system, a high-voltage DC source is supplied to both electrodes, remaining constant in time for the exposed electrode. Meanwhile, the covered electrode is periodically grounded for several microseconds and allowed to rise back to the source DC level. To test the actuators' ability to interact with and modify the formation of stall cells, a facility has been designed and constructed around nonconductive fan blades. The actuators are installed in the fan casing near the blade tips. The instrumentation allows for the measurement of rotating pressure disturbances (traveling stall cells) in this tip gap region as well as fan performance characteristics including pressure rise and flow rate. The casing plasma actuation is found to reduce the correlation of the rotating stall cells, thereby extending the stall margin of the fan. Various azimuthal arrangements of the plasma actuator casing treatment is explored, as well as input voltage levels to the actuator to determine optimum conditions. NASA SBIR Contract NNX14CC12C.

  6. Autographa californica Nucleopolyhedrovirus AC141 (Exon0), a Potential E3 Ubiquitin Ligase, Interacts with Viral Ubiquitin and AC66 To Facilitate Nucleocapsid Egress.

    PubMed

    Biswas, Siddhartha; Willis, Leslie G; Fang, Minggang; Nie, Yingchao; Theilmann, David A

    2018-02-01

    During the infection cycle of Autographa californica multiple nucleopolyhedrovirus (AcMNPV), two forms of virions are produced, budded virus (BV) and occlusion-derived virus (ODV). Nucleocapsids that form BV have to egress from the nucleus, whereas nucleocapsids that form ODV remain inside the nucleus. The molecular mechanism that determines whether nucleocapsids remain inside or egress from the nucleus is unknown. AC141 (a predicted E3 ubiquitin ligase) and viral ubiquitin (vUbi) have both been shown to be required for efficient BV production. In this study, it was hypothesized that vUbi interacts with AC141, and in addition, that this interaction was required for BV production. Deletion of both ac141 and vubi restricted viral infection to a single cell, and BV production was completely eliminated. AC141 was ubiquitinated by either vUbi or cellular Ubi, and this interaction was required for optimal BV production. Nucleocapsids in BV, but not ODV, were shown to be specifically ubiquitinated by vUbi, including a 100-kDa protein, as well as high-molecular-weight conjugates. The viral ubiquitinated 100-kDa BV-specific nucleocapsid protein was identified as AC66, which is known to be required for BV production and was shown by coimmunoprecipitation and mass spectrometry to interact with AC141. Confocal microscopy also showed that AC141, AC66, and vUbi interact at the nuclear periphery. These results suggest that ubiquitination of nucleocapsid proteins by vUbi functions as a signal to determine if a nucleocapsid will egress from the nucleus and form BV or remain in the nucleus to form ODV. IMPORTANCE Baculoviruses produce two types of virions called occlusion-derived virus (ODV) and budded virus (BV). ODVs are required for oral infection, whereas BV enables the systemic spread of virus to all host tissues, which is critical for killing insects. One of the important steps for BV production is the export of nucleocapsids out of the nucleus. This study investigated the

  7. Cell cycle-dependent changes in H3K56ac in human cells

    PubMed Central

    Stejskal, Stanislav; Stepka, Karel; Tesarova, Lenka; Stejskal, Karel; Matejkova, Martina; Simara, Pavel; Zdrahal, Zbynek; Koutna, Irena

    2015-01-01

    The incorporation of histone H3 with an acetylated lysine 56 (H3K56ac) into the nucleosome is important for chromatin remodeling and serves as a marker of new nucleosomes during DNA replication and repair in yeast. However, in human cells, the level of H3K56ac is greatly reduced, and its role during the cell cycle is controversial. Our aim was to determine the potential of H3K56ac to regulate cell cycle progression in different human cell lines. A significant increase in the number of H3K56ac foci, but not in H3K56ac protein levels, was observed during the S and G2 phases in cancer cell lines, but was not observed in embryonic stem cell lines. Despite this increase, the H3K56ac signal was not present in late replication chromatin, and H3K56ac protein levels did not decrease after the inhibition of DNA replication. H3K56ac was not tightly associated with the chromatin and was primarily localized to active chromatin regions. Our results support the role of H3K56ac in transcriptionally active chromatin areas but do not confirm H3K56ac as a marker of newly synthetized nucleosomes in DNA replication. PMID:26645646

  8. Thin optical display panel

    DOEpatents

    Veligdan, James Thomas

    1997-01-01

    An optical display includes a plurality of optical waveguides each including a cladding bound core for guiding internal display light between first and second opposite ends by total internal reflection. The waveguides are stacked together to define a collective display thickness. Each of the cores includes a heterogeneous portion defining a light scattering site disposed longitudinally between the first and second ends. Adjacent ones of the sites are longitudinally offset from each other for forming a longitudinal internal image display over the display thickness upon scattering of internal display light thereagainst for generating a display image. In a preferred embodiment, the waveguides and scattering sites are transparent for transmitting therethrough an external image in superposition with the display image formed by scattering the internal light off the scattering sites for defining a heads up display.

  9. Polyplanar optical display

    NASA Astrophysics Data System (ADS)

    Veligdan, James T.; Beiser, Leo; Biscardi, Cyrus; Brewster, Calvin; DeSanto, Leonard

    1997-07-01

    The polyplanar optical display (POD) is a unique display screen which can be use with any projection source. This display screen is 2 inches thick and has a matte black face which allows for high contrast images. The prototype being developed is a form, fit and functional replacement display for the B-52 aircraft which uses a monochrome ten-inch display. The new display uses a 100 milliwatt green solid state laser as its optical source. In order to produce real- time video, the laser light is being modulated by a digital light processing (DLP) chip manufactured by Texas Instruments, Inc. A variable astigmatic focusing system is used to produce a stigmatic image on the viewing face of the POD. In addition to the optical design, we discuss the electronic interfacing to the DLP chip, the opto-mechanical design and viewing angle characteristics.

  10. Nonlinear pulse propagation and phase velocity of laser-driven plasma waves

    NASA Astrophysics Data System (ADS)

    Benedetti, Carlo; Rossi, Francesco; Schroeder, Carl; Esarey, Eric; Leemans, Wim

    2014-10-01

    We investigate and characterize the laser evolution and plasma wave excitation by a relativistically intense, short-pulse laser propagating in a preformed parabolic plasma channel, including the effects of pulse steepening, frequency redshifting, and energy depletion. We derived in 3D, and in the weakly relativistic intensity regime, analytical expressions for the laser energy depletion, the pulse self-steepening rate, the laser intensity centroid velocity, and the phase velocity of the plasma wave. Analytical results have been validated numerically using the 2D-cylindrical, ponderomotive code INF&RNO. We also discuss the extension of these results to the nonlinear regime, where an analytical theory of the nonlinear wake phase velocity is lacking. Work supported by the Office of Science, Office of High Energy Physics, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231.

  11. Energy saving in ac generators

    NASA Technical Reports Server (NTRS)

    Nola, F. J.

    1980-01-01

    Circuit cuts no-load losses, without sacrificing full-load power. Phase-contro circuit includes gate-controlled semiconductor switch that cuts off applied voltage for most of ac cycle if generator idling. Switch "on" time increases when generator is in operation.

  12. Function analysis of Ac-PCNA and Sf-PCNA during the Autographa californica multiple nucleopolyhedrovirus infection process.

    PubMed

    Fu, Yuejun; Wang, Ruisheng; Liang, Aihua

    2018-06-01

    The baculovirus Autographa californica multiple nucleopolyhedrovirus (AcMNPV) possesses a gene, ac-pcna or ac49, which encodes a protein with similarity to proliferating cell nuclear antigen (PCNA). Homologs of this gene code for DNA polymerase processivity factors and are essential in the DNA replication systems. But the function of ac-pcna still remains unclear. To define the function of Ac-pcna in AcMNPV and Sf-pcna in host Sf9 cells, Bac-to-Bac baculovirus expression system was used to generate two recombinant baculoviruses: AcMNPV-Ac-pcna-EGFP and AcMNPV-Sf-pcna-EGFP. Results indicated that AcMNPV-mediated overexpression of Ac-PCNA and Sf-PCNA could stimulate replication of AcMNPV genome in the host Sf9 cells. Meanwhile, either AcMNPV-Ac-pcna-EGFP or AcMNPV-Sf-pcna-EGFP had a significant stimulating effect on Sf9 genome replication during infection. We also found that Ac-PCNA and Sf-PCNA could promote the production of budded virus. Ac-PCNA could improve the transcription level of ie2 gene dramatically and further improved the transcription of late gene, for example 38 K and vp39, at 12 h p.i.. Moreover, insecticidal potency test showed that the larvae of Beet armyworm in the AcMNPV-Ac-pcna-EGFP and AcMNPV-Sf-pcna-EGFP groups had a higher mortality rate (83.33 and 91.67%), a lower pupation rate (16.67 and 8.33%), and a lower emergence rate (6.67 and 3.33%), compared with those in AcMNPV-EGFP group. The function of Ac-PCNA and Sf-PCNA was confirmed in this study, which provided the theoretical foundation for using and modifying AcMNPV.

  13. Cellulose synthase complexes display distinct dynamic behaviors during xylem transdifferentiation.

    PubMed

    Watanabe, Yoichiro; Schneider, Rene; Barkwill, Sarah; Gonzales-Vigil, Eliana; Hill, Joseph L; Samuels, A Lacey; Persson, Staffan; Mansfield, Shawn D

    2018-06-05

    In plants, plasma membrane-embedded CELLULOSE SYNTHASE (CESA) enzyme complexes deposit cellulose polymers into the developing cell wall. Cellulose synthesis requires two different sets of CESA complexes that are active during cell expansion and secondary cell wall thickening, respectively. Hence, developing xylem cells, which first undergo cell expansion and subsequently deposit thick secondary walls, need to completely reorganize their CESA complexes from primary wall- to secondary wall-specific CESAs. Using live-cell imaging, we analyzed the principles underlying this remodeling. At the onset of secondary wall synthesis, the primary wall CESAs ceased to be delivered to the plasma membrane and were gradually removed from both the plasma membrane and the Golgi. For a brief transition period, both primary wall- and secondary wall-specific CESAs coexisted in banded domains of the plasma membrane where secondary wall synthesis is concentrated. During this transition, primary and secondary wall CESAs displayed discrete dynamic behaviors and sensitivities to the inhibitor isoxaben. As secondary wall-specific CESAs were delivered and inserted into the plasma membrane, the primary wall CESAs became concentrated in prevacuolar compartments and lytic vacuoles. This adjustment in localization between the two CESAs was accompanied by concurrent decreased primary wall CESA and increased secondary wall CESA protein abundance. Our data reveal distinct and dynamic subcellular trafficking patterns that underpin the remodeling of the cellulose biosynthetic machinery, resulting in the removal and degradation of the primary wall CESA complex with concurrent production and recycling of the secondary wall CESAs. Copyright © 2018 the Author(s). Published by PNAS.

  14. Dimensionless factors for an alternating-current non-thermal arc plasma

    NASA Astrophysics Data System (ADS)

    Zhang, Si-Yuan; Li, Xiao-Song; Liu, Jin-Bao; Liu, Jing-Lin; Li, He-Ping; Zhu, Ai-Min

    2016-12-01

    A gliding arc discharge, as a source of warm plasma combining advantages of both thermal and cold plasmas, would have promising application prospects in the fields of fuel conversion, combustion enhancement, material synthesis, surface modifications, pollution control, etc. In order to gain insight into the features of an alternating-current gliding arc discharge plasma, three dimensionless factors, i.e., the extinction span (ψ), current lag (δ), and heating lag (χ) factors are proposed in this letter based on the measured waveforms of the discharge voltage and current in an AC gliding arc discharge plasma. The influences of the driving frequency of the power supply (f) on these three dimensionless parameters are investigated experimentally with the explanations on the physical meanings of these factors. The experimental results show that a higher value of f would lead to the lower values of ψ and δ, as well as a higher value of χ. These experimental phenomena indicate a lower threshold ignition voltage of the discharges, a lower current-growth inertia of the gliding arcs and a larger relative thermal inertia of the plasmas with increase the driving frequency of the power supply in the operating parameter range studied in this letter.

  15. Context based computational analysis and characterization of ARS consensus sequences (ACS) of Saccharomyces cerevisiae genome.

    PubMed

    Singh, Vinod Kumar; Krishnamachari, Annangarachari

    2016-09-01

    Genome-wide experimental studies in Saccharomyces cerevisiae reveal that autonomous replicating sequence (ARS) requires an essential consensus sequence (ACS) for replication activity. Computational studies identified thousands of ACS like patterns in the genome. However, only a few hundreds of these sites act as replicating sites and the rest are considered as dormant or evolving sites. In a bid to understand the sequence makeup of replication sites, a content and context-based analysis was performed on a set of replicating ACS sequences that binds to origin-recognition complex (ORC) denoted as ORC-ACS and non-replicating ACS sequences (nrACS), that are not bound by ORC. In this study, DNA properties such as base composition, correlation, sequence dependent thermodynamic and DNA structural profiles, and their positions have been considered for characterizing ORC-ACS and nrACS. Analysis reveals that ORC-ACS depict marked differences in nucleotide composition and context features in its vicinity compared to nrACS. Interestingly, an A-rich motif was also discovered in ORC-ACS sequences within its nucleosome-free region. Profound changes in the conformational features, such as DNA helical twist, inclination angle and stacking energy between ORC-ACS and nrACS were observed. Distribution of ACS motifs in the non-coding segments points to the locations of ORC-ACS which are found far away from the adjacent gene start position compared to nrACS thereby enabling an accessible environment for ORC-proteins. Our attempt is novel in considering the contextual view of ACS and its flanking region along with nucleosome positioning in the S. cerevisiae genome and may be useful for any computational prediction scheme.

  16. Schematic displays for the Space Shuttle Orbiter multifunction cathode-ray-tube display system

    NASA Technical Reports Server (NTRS)

    Weiss, W.

    1979-01-01

    A standardized procedure for developing cathode ray tube displayed schematic diagrams. The displaying of Spacelab information on the space shuttle orbiter multifunction cathode ray tube display system is used to illustrate this procedure. Schematic displays with the equivalent tabular displays are compared.

  17. [Analysis of AC/A ratio after myopic excimer laser in situ keratomileusis].

    PubMed

    Wu, Xiao-ying; Liu, Shuang-zhen

    2003-03-01

    To study the changes of AC/A ratio of myopia after excimer laser in situ keratomileusis (LASIK). 135 myopia patients were treated by LASIK, their AC/A ratios were measured with synoptohore before surgery and 3 months after surgery. The average AC/A ratios of naked eyes or eyes wearing glasses before surgery and the naked after surgery were (0.724 +/- 0.587) (Delta)/D, (2.754 +/- 1.565) (Delta)/D, (1.618 +/- 1.027) (Delta)/D in turn. There were significant difference among those groups (P < 0.001). That also appeared in different degree of myopia naked before surgery (P < 0.01). We found no significant difference between the groups wearing glasses before surgery and naked after surgery (P > 0.05). A positive correlation was built up between postoperative AC/A ratio and AC/A ratio of wearing glasses or refractive diopter before surgery (r = 0.550, P < 0.001; r = 0.185, P < 0.005). And the postoperative AC/A ratios had a negative correlation to age or length of ocular axis (r = -0.340, P < 0.001; r = -0.192, P < 0.002). The regression equation for postoperative AC/A ratios was figured out as Y((Delta)/D) = 4.080 0 - 0.031 8X(1) - 0.097 1X(2) + 0.325 0X(3) (P < 0.001). X(1) = age (year), X(2) = length of ocular axis (mm), X(3) = preoperative AC/A ratio with weaning glasses ((Delta)/D). The naked AC/A ratios are higher than the preoperative's after LASIK, but lower than the wearing glasses's before surgery. It is influenced by the factors, such as: the preoperative AC/A ratio of wearing glasses, the length of ocular axis and the age.

  18. Fine Structure of a Laser-Plasma Filament in Air

    NASA Astrophysics Data System (ADS)

    Eisenmann, Shmuel; Pukhov, Anatoly; Zigler, Arie

    2007-04-01

    The ability to select and stabilize a single filament during propagation of an ultrashort high-intensity laser pulse in air makes it possible to examine the longitudinal structure of the plasma channel left in its wake. We present detailed measurements of plasma density variations along laser propagation. Over the length of the filament, electron density variations of 3 orders of magnitude are measured. They display evidence of a meter-long postionization range, along which a self-guided structure is observed coupled with a low plasma density, corresponding to ˜3 orders of magnitude decrease from the peak density level.

  19. Influence of ZrO2 addition on the microstructure and discharge properties of Mg-Zr-O protective layers in alternating current plasma display panels

    NASA Astrophysics Data System (ADS)

    Guo, Bingang; Liu, Chunliang; Song, Zhongxiao; Liu, Liu; Fan, Yufeng; Xia, Xing; Fan, Duowang

    2005-08-01

    Mg-Zr-O protective layers for alternating current plasma display panels were deposited by e-beam evaporation. The effect of the ZrO2 addition on both the discharge properties [firing voltage Vf, minimum sustaining voltage Vs, and memory coefficient (MC)] and the microstructure of deposited Mg-Zr-O films were investigated. The results show that the film microstructure changes and the electron emission enhancement due to the ZrO2 addition are the main reasons for the improvements of the discharge properties of Mg-Zr-O films. A small amount of Zr solution in MgO under its solid solubility can effectively increase the outer-shell valence electron emission yield so as to decrease Vf and Vs compared with using a pure MgO protective layer. The ZrO2/(MgO +ZrO2) ratio has a great effect on the film surface conditions. Proper surface morphologies make a good contribution to obtain large MC in accordance with lower firing voltage.

  20. Initial transport validation studies using NSTX-U L-mode plasmas

    NASA Astrophysics Data System (ADS)

    Guttenfelder, Walter; Battaglia, D.; Bell, R. E.; Boyer, M. D.; Crocker, N.; Diallo, A.; Ferraro, N.; Gerhardt, S. P.; Kaye, S. M.; Leblanc, B. P.; Liu, D.; Menard, J. E.; Mueller, D.; Myer, C.; Podesta, M.; Raman, R.; Ren, Y.; Sabbagh, S.; Smith, D.

    2016-10-01

    A variety of stationary L-mode plasmas have been successfully developed in NSTX-U for physics validation studies. The plasmas span a range of density (1-4 ×1019 m-3) , plasma current (0.65-1.0 MA), and neutral beam heating power (<=4 MW), taking advantage of new, more tangential neutral beam sources to vary rotation profiles. Transport analysis (TRANSP) and turbulence measurements (BES, reflectometry) of these plasmas will be illustrated and compared with initial microstability and transport predictions. In particular, the normalized beta of these L-modes range between βN = 1-2, providing a valuable bridge in parameter space between (i) H-modes at comparable beta in conventional tokamaks (R/a 3, βN 2), where transport models have been largely developed and tested, and (ii) low-aspect-ratio H-modes at higher beta (R/a 1.5-1.7, βN 5), where transport models are less tested and challenged by stronger electromagnetic and equilibrium effects. This work is supported by US DOE contract DE-AC02-09CH11466.

  1. Transport properties of NSTX-U L- and H-mode plasmas

    NASA Astrophysics Data System (ADS)

    Kaye, Stanley; Guttenfelder, Walter; Bell, Ron; Diallo, Ahmed; Leblanc, Ben; Podesta, Mario

    2016-10-01

    The confinement and transport properties of L- and H-mode plasmas in NSTX-U has been studied using the TRANSP code. A dedicated series of L-mode discharges was obtained to study the dependence of confinement and transport on power level and beam aiming angle. The latter is made possible by having two beamlines with 3 sources each, capable of injecting with tangency radii from Rtan = 50 to 130 cm (Rgeo = 92 cm). L-mode plasmas typically have confinement enhancement factors with H98y,2 =0.6 to 0.65, exhibiting a 25% decrease in confinement time as the beam power is raised from 1 to 3 MW. Associated with this is an increase in the electron thermal diffusivity in the core of the plasma from 3.5 to 10 m2/s. Electron thermal transport is the dominant energy loss channel in these plasmas. H-mode plasmas exhibit improved confinement, with H98y,2 =1 or above, and core electron thermal diffusivity values <1 m2/s. Details of these studies will be presented, along with the results of the beam tangency radius scan in L-mode plasmas. This research was supported by the U.S. Department of Energy contract # DE-AC02-09CH11466.

  2. Flat-panel display solutions for ground-environment military displays (Invited Paper)

    NASA Astrophysics Data System (ADS)

    Thomas, J., II; Roach, R.

    2005-05-01

    Displays for military vehicles have very distinct operational and cost requirements that differ from other military applications. These requirements demand that display suppliers to Army and Marine ground-environments provide low cost equipment that is capable of operation across environmental extremes. Inevitably, COTS components form the foundation of these "affordable" display solutions. This paper will outline the major display requirements and review the options that satisfy conflicting and difficult operational demands, using newly developed equipment as an example. Recently, a new supplier was selected for the Drivers Vision Enhancer (DVE) equipment, including the Display Control Module (DCM). The paper will outline the DVE and describe development of a new DCM solution. The DVE programme, with several thousand units presently in service and operational in conflicts such as "Operation Iraqi Freedom", represents a critical balance between cost and performance. We shall describe design considerations that include selection of COTS sources, the need to minimise display modification; video interfaces, power interfaces, operator interfaces and new provisions to optimise displayed video content.

  3. Plasma particle sources due to interactions with neutrals in a turbulent scrape-off layer of a toroidally confined plasma

    NASA Astrophysics Data System (ADS)

    Thrysøe, A. S.; Løiten, M.; Madsen, J.; Naulin, V.; Nielsen, A. H.; Rasmussen, J. Juul

    2018-03-01

    The conditions in the edge and scrape-off layer (SOL) of magnetically confined plasmas determine the overall performance of the device, and it is of great importance to study and understand the mechanics that drive transport in those regions. If a significant amount of neutral molecules and atoms is present in the edge and SOL regions, those will influence the plasma parameters and thus the plasma confinement. In this paper, it is displayed how neutrals, described by a fluid model, introduce source terms in a plasma drift-fluid model due to inelastic collisions. The resulting source terms are included in a four-field drift-fluid model, and it is shown how an increasing neutral particle density in the edge and SOL regions influences the plasma particle transport across the last-closed-flux-surface. It is found that an appropriate gas puffing rate allows for the edge density in the simulation to be self-consistently maintained due to ionization of neutrals in the confined region.

  4. The application of Halbach cylinders to brushless ac servo motors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Atallah, K.; Howe, D.

    1998-07-01

    Halbach cylinders are applied to brushless ac servo motors. It is shown that a sinusoidal back-emf waveform and a low cogging torque can be achieved without recourse to conventional design features such as distributed windings and/or stator/rotor skew. A technique for imparting a multipole Halbach magnetization distribution on an isotropic permanent magnet cylinder is described, and it is shown that the torque capability of a Halbach ac servo motor can be up to 33% higher than conventional brushless permanent magnet ac motors.

  5. Seamless tiled display system

    NASA Technical Reports Server (NTRS)

    Dubin, Matthew B. (Inventor); Larson, Brent D. (Inventor); Kolosowsky, Aleksandra (Inventor)

    2006-01-01

    A modular and scalable seamless tiled display apparatus includes multiple display devices, a screen, and multiple lens assemblies. Each display device is subdivided into multiple sections, and each section is configured to display a sectional image. One of the lens assemblies is optically coupled to each of the sections of each of the display devices to project the sectional image displayed on that section onto the screen. The multiple lens assemblies are configured to merge the projected sectional images to form a single tiled image. The projected sectional images may be merged on the screen by magnifying and shifting the images in an appropriate manner. The magnification and shifting of these images eliminates any visual effect on the tiled display that may result from dead-band regions defined between each pair of adjacent sections on each display device, and due to gaps between multiple display devices.

  6. Reconstitutional Mutagenesis of the Maize P Gene by Short-Range Ac Transpositions

    PubMed Central

    Moreno, M. A.; Chen, J.; Greenblatt, I.; Dellaporta, S. L.

    1992-01-01

    The tendency for Ac to transpose over short intervals has been utilized to develop insertional mutagenesis and fine structure genetic mapping strategies in maize. We recovered excisions of Ac from the P gene and insertions into nearby chromosomal sites. These closely linked Ac elements reinserted into the P gene, reconstituting over 250 unstable variegated alleles. Reconstituted alleles condition a variety of variegation patterns that reflect the position and orientation of Ac within the P gene. Molecular mapping and DNA sequence analyses have shown that reinsertion sites are dispersed throughout a 12.3-kb chromosomal region in the promoter, exons and introns of the P gene, but in some regions insertions sites were clustered in a nonrandom fashion. Transposition profiles and target site sequence data obtained from these studies have revealed several features of Ac transposition including its preference for certain target sites. These results clearly demonstrate the tendency of Ac to transpose to nearby sites in both proximal and distal directions from the donor site. With minor modifications, reconstitutional mutagenesis should be applicable to many Ac-induced mutations in maize and in other plant species and can possibly be extended to other eukaryotic transposon systems as well. PMID:1325389

  7. Patch Finder Plus (PFplus): a web server for extracting and displaying positive electrostatic patches on protein surfaces.

    PubMed

    Shazman, Shula; Celniker, Gershon; Haber, Omer; Glaser, Fabian; Mandel-Gutfreund, Yael

    2007-07-01

    Positively charged electrostatic patches on protein surfaces are usually indicative of nucleic acid binding interfaces. Interestingly, many proteins which are not involved in nucleic acid binding possess large positive patches on their surface as well. In some cases, the positive patches on the protein are related to other functional properties of the protein family. PatchFinderPlus (PFplus) http://pfp.technion.ac.il is a web-based tool for extracting and displaying continuous electrostatic positive patches on protein surfaces. The input required for PFplus is either a four letter PDB code or a protein coordinate file in PDB format, provided by the user. PFplus computes the continuum electrostatics potential and extracts the largest positive patch for each protein chain in the PDB file. The server provides an output file in PDB format including a list of the patch residues. In addition, the largest positive patch is displayed on the server by a graphical viewer (Jmol), using a simple color coding.

  8. Patch Finder Plus (PFplus): A web server for extracting and displaying positive electrostatic patches on protein surfaces

    PubMed Central

    Shazman, Shula; Celniker, Gershon; Haber, Omer; Glaser, Fabian; Mandel-Gutfreund, Yael

    2007-01-01

    Positively charged electrostatic patches on protein surfaces are usually indicative of nucleic acid binding interfaces. Interestingly, many proteins which are not involved in nucleic acid binding possess large positive patches on their surface as well. In some cases, the positive patches on the protein are related to other functional properties of the protein family. PatchFinderPlus (PFplus) http://pfp.technion.ac.il is a web-based tool for extracting and displaying continuous electrostatic positive patches on protein surfaces. The input required for PFplus is either a four letter PDB code or a protein coordinate file in PDB format, provided by the user. PFplus computes the continuum electrostatics potential and extracts the largest positive patch for each protein chain in the PDB file. The server provides an output file in PDB format including a list of the patch residues. In addition, the largest positive patch is displayed on the server by a graphical viewer (Jmol), using a simple color coding. PMID:17537808

  9. Hybrid inverter for HVDC/weak AC system interconnection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tam, K.S.

    1985-01-01

    The concept of the hybrid converter is introduced. By independently controlling a naturally commutated converter (NCC) and an artificially commutated converter (ACC), real power and reactive power can be controlled independently. Alternatively, the ac bus voltage can be regulated without affecting the real power transfer. Independent control is feasible only within certain operating boundaries. Twelve pulse operation, sequential control, and complementary circuits may be viewed as variations of the hybrid converter. The concept of the hybrid converter is demonstrated by digital simulation. At the current state of technology, the NCC is best implemented by a 6-pulse bridge using thyristors asmore » the switching elements. A survey of power electronics applicable to HVDC applications reveals that the capacitively commutated current-sourced converters are either technically or economically better than the other alternatives for the implementation of the ACC. The digital simulation results show that the problems of operating an HVDC system into a weak ac system can be solved by using a hybrid inverter. A new control scheme, the zero Q control, is developed. With no reactive power interaction between the dc system and the ac system, the stability of the HVDC/weak ac system operation is significantly improved. System start-up and fault recovery is fast and stable.« less

  10. Microlaser-based displays

    NASA Astrophysics Data System (ADS)

    Bergstedt, Robert; Fink, Charles G.; Flint, Graham W.; Hargis, David E.; Peppler, Philipp W.

    1997-07-01

    Laser Power Corporation has developed a new type of projection display, based upon microlaser technology and a novel scan architecture, which provides the foundation for bright, extremely high resolution images. A review of projection technologies is presented along with the limitations of each and the difficulties they experience in trying to generate high resolution imagery. The design of the microlaser based projector is discussed along with the advantage of this technology. High power red, green, and blue microlasers have been designed and developed specifically for use in projection displays. These sources, in combination with high resolution, high contrast modulator, produce a 24 bit color gamut, capable of supporting the full range of real world colors. The new scan architecture, which reduces the modulation rate and scan speeds required, is described. This scan architecture, along with the inherent brightness of the laser provides the fundamentals necessary to produce a 5120 by 4096 resolution display. The brightness and color uniformity of the display is excellent, allowing for tiling of the displays with far fewer artifacts than those in a traditionally tiled display. Applications for the display include simulators, command and control centers, and electronic cinema.

  11. Maintenance Procedure Display: Head Mounted Display (HMD) Evaluations

    NASA Technical Reports Server (NTRS)

    Whitmore, Milrian; Litaker, Harry L., Jr.; Solem, Jody A.; Holden, Kritina L.; Hoffman, Ronald R.

    2007-01-01

    A viewgraph presentation describing maintenance procedures for head mounted displays is shown. The topics include: 1) Study Goals; 2) Near Eye Displays (HMDs); 3) Design; 4) Phase I-Evaluation Methods; 5) Phase 1 Results; 6) Improved HMD Mounting; 7) Phase 2 -Evaluation Methods; 8) Phase 2 Preliminary Results; and 9) Next Steps.

  12. Abscisic Acid Antagonizes Ethylene Production through the ABI4-Mediated Transcriptional Repression of ACS4 and ACS8 in Arabidopsis.

    PubMed

    Dong, Zhijun; Yu, Yanwen; Li, Shenghui; Wang, Juan; Tang, Saijun; Huang, Rongfeng

    2016-01-04

    Increasing evidence has revealed that abscisic acid (ABA) negatively modulates ethylene biosynthesis, although the underlying mechanism remains unclear. To identify the factors involved, we conducted a screen for ABA-insensitive mutants with altered ethylene production in Arabidopsis. A dominant allele of ABI4, abi4-152, which produces a putative protein with a 16-amino-acid truncation at the C-terminus of ABI4, reduces ethylene production. By contrast, two recessive knockout alleles of ABI4, abi4-102 and abi4-103, result in increased ethylene evolution, indicating that ABI4 negatively regulates ethylene production. Further analyses showed that expression of the ethylene biosynthesis genes ACS4, ACS8, and ACO2 was significantly decreased in abi4-152 but increased in the knockout mutants, with partial dependence on ABA. Chromatin immunoprecipitation-quantitative PCR assays showed that ABI4 directly binds the promoters of these ethylene biosynthesis genes and that ABA enhances this interaction. A fusion protein containing the truncated ABI4-152 peptide accumulated to higher levels than its full-length counterpart in transgenic plants, suggesting that ABI4 is destabilized by its C terminus. Therefore, our results demonstrate that ABA negatively regulates ethylene production through ABI4-mediated transcriptional repression of the ethylene biosynthesis genes ACS4 and ACS8 in Arabidopsis. Copyright © 2016 The Author. Published by Elsevier Inc. All rights reserved.

  13. Ringing After a High-Energy Collision: Ambipolar Oscillations During Impact Plasma Expansion

    NASA Technical Reports Server (NTRS)

    Zimmerman, M. I.; Farrell, W. M.; Stubbs, T. J.

    2012-01-01

    High-velocity impacts on the Moon and other airless bodies deliver energy and material to the lunar surface and exosphere. The target and i mpactor material may become vaporized and ionized to form a collision al plasma that expands outward and eventually becomes collisionless. In the present work, kinetic simulations of the later collision less stage of impact plasma expansion are performed. Attention is paid to characterizing "ambipolar oscillations" in which thermodynamic distur bances propagate outward to generate "ringing" within the expanding e lectron cloud, which could radiate an electromagnetic signature of lo cal plasma conditions. The process is not unlike a beam-plasma intera ction, with the perturbing electron population in the present case ac ting as a highly thermal "beam" that resonates along the expanding de nsity gradient. Understanding the electromagnetic aspects of impact p lasma expansion could provide insight into the lasting effects of nat ural, impact-generated currents on airless surfaces and charging haza rds to human exploration infrastructure and instrumentation.

  14. Polyplanar optic display

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veligdan, J.; Biscardi, C.; Brewster, C.

    1997-07-01

    The Polyplanar Optical Display (POD) is a unique display screen which can be used with any projection source. This display screen is 2 inches thick and has a matte black face which allows for high contrast images. The prototype being developed is a form, fit and functional replacement display for the B-52 aircraft which uses a monochrome ten-inch display. The new display uses a 100 milliwatt green solid state laser (532 nm) as its optical source. In order to produce real-time video, the laser light is being modulated by a Digital Light Processing (DLP{trademark}) chip manufactured by Texas Instruments, Inc.more » A variable astigmatic focusing system is used to produce a stigmatic image on the viewing face of the POD. In addition to the optical design, the authors discuss the electronic interfacing to the DLP{trademark} chip, the opto-mechanical design and viewing angle characteristics.« less

  15. ORFeome Phage Display.

    PubMed

    Zantow, Jonas; Moreira, Gustavo Marçal Schmidt Garcia; Dübel, Stefan; Hust, Michael

    2018-01-01

    ORFeome phage display allows the efficient functional screening of entire proteomes or even metaproteomes to identify immunogenic proteins. For this purpose, randomly fragmented, whole genomes or metagenomes are cloned into a phage-display vector allowing positive selection for open reading frames (ORF) to improve the library quality. These libraries display all possible proteins encoded by a pathogen or a microbiome on the phage surface. Consequently, immunogenic proteins can be selected from these libraries using disease-related immunoglobulins from patient serum. ORFeome phage display in particular allows the identification of immunogenic proteins that are only expressed in the host-pathogen interaction but not in cultivation, as well as the detection of very low expressed and very small immunogens and immunogenic proteins of non-cultivable organisms. The identified immunogenic proteins are potential biomarkers for the development of diagnostic assays or vaccines. These articles will give an introduction to ORFeome phage-display technology and give detailed protocols to identify immunogenic proteins by phage display.

  16. Miniaturized cathodic arc plasma source

    DOEpatents

    Anders, Andre; MacGill, Robert A.

    2003-04-15

    A cathodic arc plasma source has an anode formed of a plurality of spaced baffles which extend beyond the active cathode surface of the cathode. With the open baffle structure of the anode, most macroparticles pass through the gaps between the baffles and reflect off the baffles out of the plasma stream that enters a filter. Thus the anode not only has an electrical function but serves as a prefilter. The cathode has a small diameter, e.g. a rod of about 1/4 inch (6.25 mm) diameter. Thus the plasma source output is well localized, even with cathode spot movement which is limited in area, so that it effectively couples into a miniaturized filter. With a small area cathode, the material eroded from the cathode needs to be replaced to maintain plasma production. Therefore, the source includes a cathode advancement or feed mechanism coupled to cathode rod. The cathode also requires a cooling mechanism. The movable cathode rod is housed in a cooled metal shield or tube which serves as both a current conductor, thus reducing ohmic heat produced in the cathode, and as the heat sink for heat generated at or near the cathode. Cooling of the cathode housing tube is done by contact with coolant at a place remote from the active cathode surface. The source is operated in pulsed mode at relatively high currents, about 1 kA. The high arc current can also be used to operate the magnetic filter. A cathodic arc plasma deposition system using this source can be used for the deposition of ultrathin amorphous hard carbon (a-C) films for the magnetic storage industry.

  17. Characterization on performance of micromixer using DC-biased AC electroosmosis

    NASA Astrophysics Data System (ADS)

    Park, Bi-O.; Song, Simon

    2010-11-01

    An active micromixer using DC-biased AC-Electroosmosis (ACEO) is investigated to figure out the effects of design parameters on the mixing performance. The mixer consists of a straight microchannel, with a cross section of 60 x 100 μm, and gold electrode pairs fabricated in the microchannel. The design parameters include the number of electrode pairs, flow rate, DC-biased voltage, AC voltage and AC frequency. First, we found that a mixing index became 80% 100 μm downstream of a single electrode pair with a length of 2 mm when applying a 25Vpp, 2.0 VDC, 100 kHz sine signal to the electrodes. With decreasing AC frequency, the mixing index is affected little. But the mixing index significantly increases with increasing either DC-biased voltage or AC voltage. Also, we were able to increase the mixing index up to 90% by introducing alternating vortices with multiple electrode pairs. Finally, we discovered that the mixing index decreases as the flow rate increases in the microchannel, and there is an optimal number of electrode pairs with respect to a flow rate. Detailed quantitative measurement results will be presented at the meeting.

  18. Hybrid AC-High Voltage DC Grid Stability and Controls

    NASA Astrophysics Data System (ADS)

    Yu, Jicheng

    The growth of energy demands in recent years has been increasing faster than the expansion of transmission facility construction. This tendency cooperating with the continuous investing on the renewable energy resources drives the research, development, and construction of HVDC projects to create a more reliable, affordable, and environmentally friendly power grid. Constructing the hybrid AC-HVDC grid is a significant move in the development of the HVDC techniques; the form of dc system is evolving from the point-to-point stand-alone dc links to the embedded HVDC system and the multi-terminal HVDC (MTDC) system. The MTDC is a solution for the renewable energy interconnections, and the MTDC grids can improve the power system reliability, flexibility in economic dispatches, and converter/cable utilizing efficiencies. The dissertation reviews the HVDC technologies, discusses the stability issues regarding the ac and HVDC connections, proposes a novel power oscillation control strategy to improve system stability, and develops a nonlinear voltage droop control strategy for the MTDC grid. To verify the effectiveness the proposed power oscillation control strategy, a long distance paralleled AC-HVDC transmission test system is employed. Based on the PSCAD/EMTDC platform simulation results, the proposed power oscillation control strategy can improve the system dynamic performance and attenuate the power oscillations effectively. To validate the nonlinear voltage droop control strategy, three droop controls schemes are designed according to the proposed nonlinear voltage droop control design procedures. These control schemes are tested in a hybrid AC-MTDC system. The hybrid AC-MTDC system, which is first proposed in this dissertation, consists of two ac grids, two wind farms and a five-terminal HVDC grid connecting them. Simulation studies are performed in the PSCAD/EMTDC platform. According to the simulation results, all the three design schemes have their unique salient

  19. Material for electrodes of low temperature plasma generators

    DOEpatents

    Caplan, Malcolm; Vinogradov, Sergel Evge'evich; Ribin, Valeri Vasil'evich; Shekalov, Valentin Ivanovich; Rutberg, Philip Grigor'evich; Safronov, Alexi Anatol'evich

    2008-12-09

    Material for electrodes of low temperature plasma generators. The material contains a porous metal matrix impregnated with a material emitting electrons. The material uses a mixture of copper and iron powders as a porous metal matrix and a Group IIIB metal component such as Y.sub.2O.sub.3 is used as a material emitting electrons at, for example, the proportion of the components, mass %: iron: 3-30; Y.sub.2O.sub.3:0.05-1; copper: the remainder. Copper provides a high level of heat conduction and electric conductance, iron decreases intensity of copper evaporation in the process of plasma creation providing increased strength and lifetime, Y.sub.2O.sub.3 provides decreasing of electronic work function and stability of arc burning. The material can be used for producing the electrodes of low temperature AC plasma generators used for destruction of liquid organic wastes, medical wastes, and municipal wastes as well as for decontamination of low level radioactive waste, the destruction of chemical weapons, warfare toxic agents, etc.

  20. Material for electrodes of low temperature plasma generators

    DOEpatents

    Caplan, Malcolm; Vinogradov, Sergel Evge'evich; Ribin, Valeri Vasil'evich; Shekalov, Valentin Ivanovich; Rutberg, Philip Grigor'evich; Safronov, Alexi Anatol'evich; Shiryaev, Vasili Nikolaevich

    2010-03-02

    Material for electrodes of low temperature plasma generators. The material contains a porous metal matrix impregnated with a material emitting electrons. The material uses a mixture of copper and iron powders as a porous metal matrix and a Group IIIB metal component such as Y.sub.2O.sub.3 is used as a material emitting electrons at, for example, the proportion of the components, mass %: iron:3-30; Y.sub.2O.sub.3:0.05-1; copper: the remainder. Copper provides a high level of heat conduction and electric conductance, iron decreases intensity of copper evaporation in the process of plasma creation providing increased strength and lifetime, Y.sub.2O.sub.3 provides decreasing of electronic work function and stability of arc burning. The material can be used for producing the electrodes of low temperature AC plasma generators used for destruction of liquid organic wastes, medical wastes, municipal wastes as well as for decontamination of low level radioactive waste, the destruction of chemical weapons, warfare toxic agents, etc.

  1. High power plasma heating experiments on the Proto-MPEX facility

    NASA Astrophysics Data System (ADS)

    Bigelow, T. S.; Beers, C. J.; Biewer, T. M.; Caneses, J. F.; Caughman, J. B. O.; Diem, S. J.; Goulding, R. H.; Green, D. L.; Kafle, N.; Rapp, J.; Showers, M. A.

    2017-10-01

    Work is underway to maximize the power delivered to the plasma that is available from heating sources installed on the Prototype Materials Plasma Exposure eXperiment (Proto-MPEX) at ORNL. Proto-MPEX is a linear device that has a >100 kW, 13.56 MHz helicon plasma generator available and is intended for material sample exposure to plasmas. Additional plasma heating systems include a 10 kW 18 GHz electron cyclotron heating (ECH) system, a 25 kW 8 MHz ion cyclotron heating ICH system, and a 200 kW 28 GHz electron Bernstein wave (EBW) and ECH system. Most of the heating systems have relatively good power transmission efficiency, however, the 28 GHz EBW system has a lower efficiency owing to stringent requirements on the microwave launch characteristics for EBW coupling combined with the lower output mode purity of the early-model gyrotron in use and its compact mode converter system. A goal for the Proto-MPEX is to have a combined heating power of 200 kW injected into the plasma. Infrared emission diagnostics of the target plate combined with Thomson Scattering, Langmuir probe, and energy analyzer measurements near the target are utilized to characterize the plasmas and coupling efficiency of the heating systems. ORNL is managed by UT-Battelle, LLC, for the U.S. DOE under contract DE-AC-05-00OR22725.

  2. Effects of gas residence time of CH4/H2 on sp2 fraction of amorphous carbon films and dissociated methyl density during radical-injection plasma-enhanced chemical vapor deposition

    NASA Astrophysics Data System (ADS)

    Sugiura, Hirotsugu; Jia, Lingyun; Kondo, Hiroki; Ishikawa, Kenji; Tsutsumi, Takayoshi; Hayashi, Toshio; Takeda, Keigo; Sekine, Makoto; Hori, Masaru

    2018-06-01

    Quadruple mass spectrometric measurements of CH3 density during radical-injection plasma-enhanced chemical vapor deposition to consider the sp2 fraction of amorphous carbon (a-C) films were performed. The sp2 fraction of the a-C films reached a minimum of 46%, where the CH3 density was maximum for a residence time of 6 ms. The sp2 fraction of the a-C films was tailored with the gaseous phase CH3 density during the deposition. This knowledge is useful for understanding the formation mechanism of bonding structures in the a-C films, which enables the precise control of their electronic properties.

  3. Study of dielectric relaxation and AC conductivity of InP:S single crystal

    NASA Astrophysics Data System (ADS)

    El-Nahass, M. M.; Ali, H. A. M.; El-Shazly, E. A.

    2012-07-01

    The dielectric relaxation and AC conductivity of InP:S single crystal were studied in the frequency range from 100 to 5.25 × 105 Hz and in the temperature range from 296 to 455 K. The dependence of the dielectric constant (ɛ1) and the dielectric loss (ɛ2) on both frequency and temperature was investigated. Since no peak was observed on the dielectric loss, we used a method based on the electric modulus to evaluate the activation energy of the dielectric relaxation. Scaling of the electric modulus spectra showed that the charge transport dynamics is independent of temperature. The AC conductivity (σAC) was found to obey the power law: Aωs. Analysis of the AC conductivity data and the frequency exponent showed that the correlated barrier hopping (CBH) model is the dominant mechanism for the AC conduction. The variation of AC conductivity with temperature at different frequencies showed that σAC is a thermally activated process.

  4. AC conductivity and Dielectric Study of Chalcogenide Glasses of Se-Te-Ge System

    NASA Astrophysics Data System (ADS)

    Salman, Fathy

    2004-01-01

    The ac conductivity and dielectric properties of glassy system SexTe79 - xGe21, with x = 11, 14, 17 at.%, has been studied at temperatures 300 to 450 K and over a wide range of frequencies (50 Hz to 500 kHz). Experimental results indicate that the ac conductivity and the dielectric constants depend on temperature, frequency and Se content. The conductivity as a function of frequency exhibited two components: dc conductivity s dc, and ac conductivity s ac, where s ac ˜ w s. The mechanism of ac conductivity can be reasonably interpreted in terms of the correlated barrier hopping model (CBH). The activation energies are estimated and discussed. The dependence of ac conductivity and dielectric constants on the Se content x can be interpreted as the effect of Se fraction on the positional disorder. The impedance plot at each temperature appeared as a semicircle passes through the origin. Each semicircle is represented by an equivalent circuit of parallel resistance Rb and capacitance Cb.

  5. Practicality of magnetic compression for plasma density control

    DOE PAGES

    Gueroult, Renaud; Fisch, Nathaniel J.

    2016-03-16

    Here, plasma densification through magnetic compression has been suggested for time-resolved control of the wave properties in plasma-based accelerators [P. F. Schmit and N. J. Fisch, Phys. Rev. Lett. 109, 255003 (2012)]. Using particle in cell simulations with real mass ratio, the practicality of large magnetic compression on timescales shorter than the ion gyro-period is investigated. For compression times shorter than the transit time of a compressional Alfven wave across the plasma slab, results show the formation of two counter-propagating shock waves, leading to a highly non-uniform plasma density profile. Furthermore, the plasma slab displays large hydromagnetic like oscillations aftermore » the driving field has reached steady state. Peak compression is obtained when the two shocks collide in the mid-plane. At this instant, very large plasma heating is observed, and the plasmaβ is estimated to be about 1. Although these results point out a densification mechanism quite different and more complex than initially envisioned, these features still might be advantageous in particle accelerators.« less

  6. Dielectric behavior of AC aged polyethylene in humid environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scarpa, P.C.N.; Das-Gupta, D.K.; Bulinski, A.T.

    1996-12-31

    The present paper reports the results of a study of electrical aging of low density polyethylene (LDPE) aged in humid environment (0.1M NaCl) at an AC stress of 6kV/mm, 1kHz, at room temperature (RT) and at 65 C, and cross-linked polyethylene (XLPE) AC aged in humid environment (water) at an AC stress of 6kV/mm, 50Hz, at RT, for an extended period of time. For this study the dielectric spectroscopy data in the frequency range of 10{sup {minus}5}Hz to 10{sup 6}Hz and their comparative analysis, have been used to provide electrical analog models of the aging.

  7. Clinical relevance of drug binding to plasma proteins

    NASA Astrophysics Data System (ADS)

    Ascenzi, Paolo; Fanali, Gabriella; Fasano, Mauro; Pallottini, Valentina; Trezza, Viviana

    2014-12-01

    Binding to plasma proteins highly influences drug efficacy, distribution, and disposition. Serum albumin, the most abundant protein in plasma, is a monomeric multi-domain macromolecule that displays an extraordinary ligand binding capacity, providing a depot and carrier for many endogenous and exogenous compounds, such as fatty acids and most acidic drugs. α-1-Acid glycoprotein, the second main plasma protein, is a glycoprotein physiologically involved in the acute phase reaction and is the main carrier for basic and neutral drugs. High- and low-density lipoproteins play a limited role in drug binding and are natural drug delivery system only for few lipophilic drugs or lipid-based formulations. Several factors influence drug binding to plasma proteins, such as pathological conditions, concurrent administration of drugs, sex, and age. Any of these factors, in turn, influences drug efficacy and toxicity. Here, biochemical, biomedical, and biotechnological aspects of drug binding to plasma proteins are reviewed.

  8. Numerical and theoretical evaluations of AC losses for single and infinite numbers of superconductor strips with direct and alternating transport currents in external AC magnetic field

    NASA Astrophysics Data System (ADS)

    Kajikawa, K.; Funaki, K.; Shikimachi, K.; Hirano, N.; Nagaya, S.

    2010-11-01

    AC losses in a superconductor strip are numerically evaluated by means of a finite element method formulated with a current vector potential. The expressions of AC losses in an infinite slab that corresponds to a simple model of infinitely stacked strips are also derived theoretically. It is assumed that the voltage-current characteristics of the superconductors are represented by Bean's critical state model. The typical operation pattern of a Superconducting Magnetic Energy Storage (SMES) coil with direct and alternating transport currents in an external AC magnetic field is taken into account as the electromagnetic environment for both the single strip and the infinite slab. By using the obtained results of AC losses, the influences of the transport currents on the total losses are discussed quantitatively.

  9. Study on electromagnetic plasma propulsion using rotating magnetic field acceleration scheme

    NASA Astrophysics Data System (ADS)

    Furukawa, T.; Takizawa, K.; Kuwahara, D.; Shinohara, S.

    2017-04-01

    As one of the electromagnetic plasma acceleration systems, we have proposed a rotating magnetic field (RMF) acceleration scheme to overcome the present problem of direct plasma-electrode interactions, leading to a short lifetime with a poor plasma performance due to contamination. In this scheme, we generate a plasma by a helicon wave excited by a radio frequency (rf) antenna which has no direct-contact with a plasma. Then, the produced plasma is accelerated by the axial Lorentz force fz = jθ × Br (jθ is an azimuthal current induced by RMF, and Br is an external radial magnetic field). Erosion of electrodes and contamination are not expected in this total system since RMF coils and an rf antenna do not have contact with the plasma directly. Here, we have measured the plasma parameters (electron density ne and axial ion velocity vi) to demonstrate this RMF acceleration scheme by the use of AC currents in two sets of opposing coils to generate a RMF. The maximum increasing rate Δvi /vi was ˜28% (maximum vi of ˜3 km/s), while the density increasing rate of Δne/ne is ˜ 70% in the case of a RMF current frequency fRMF of 3 MHz, which showed a better plasma performance than that with fRMF = 5 MHz. Moreover, thrust characteristics such as a specific impulse and a thrust efficiency were discussed, although a target plasma was not optimized.

  10. Optimal Power Scheduling for a Medium Voltage AC/DC Hybrid Distribution Network

    DOE PAGES

    Zhu, Zhenshan; Liu, Dichen; Liao, Qingfen; ...

    2018-01-26

    With the great increase of renewable generation as well as the DC loads in the distribution network; DC distribution technology is receiving more attention; since the DC distribution network can improve operating efficiency and power quality by reducing the energy conversion stages. This paper presents a new architecture for the medium voltage AC/DC hybrid distribution network; where the AC and DC subgrids are looped by normally closed AC soft open point (ACSOP) and DC soft open point (DCSOP); respectively. The proposed AC/DC hybrid distribution systems contain renewable generation (i.e., wind power and photovoltaic (PV) generation); energy storage systems (ESSs); softmore » open points (SOPs); and both AC and DC flexible demands. An energy management strategy for the hybrid system is presented based on the dynamic optimal power flow (DOPF) method. The main objective of the proposed power scheduling strategy is to minimize the operating cost and reduce the curtailment of renewable generation while meeting operational and technical constraints. The proposed approach is verified in five scenarios. The five scenarios are classified as pure AC system; hybrid AC/DC system; hybrid system with interlinking converter; hybrid system with DC flexible demand; and hybrid system with SOPs. Results show that the proposed scheduling method can successfully dispatch the controllable elements; and that the presented architecture for the AC/DC hybrid distribution system is beneficial for reducing operating cost and renewable generation curtailment.« less

  11. Optimal Power Scheduling for a Medium Voltage AC/DC Hybrid Distribution Network

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, Zhenshan; Liu, Dichen; Liao, Qingfen

    With the great increase of renewable generation as well as the DC loads in the distribution network; DC distribution technology is receiving more attention; since the DC distribution network can improve operating efficiency and power quality by reducing the energy conversion stages. This paper presents a new architecture for the medium voltage AC/DC hybrid distribution network; where the AC and DC subgrids are looped by normally closed AC soft open point (ACSOP) and DC soft open point (DCSOP); respectively. The proposed AC/DC hybrid distribution systems contain renewable generation (i.e., wind power and photovoltaic (PV) generation); energy storage systems (ESSs); softmore » open points (SOPs); and both AC and DC flexible demands. An energy management strategy for the hybrid system is presented based on the dynamic optimal power flow (DOPF) method. The main objective of the proposed power scheduling strategy is to minimize the operating cost and reduce the curtailment of renewable generation while meeting operational and technical constraints. The proposed approach is verified in five scenarios. The five scenarios are classified as pure AC system; hybrid AC/DC system; hybrid system with interlinking converter; hybrid system with DC flexible demand; and hybrid system with SOPs. Results show that the proposed scheduling method can successfully dispatch the controllable elements; and that the presented architecture for the AC/DC hybrid distribution system is beneficial for reducing operating cost and renewable generation curtailment.« less

  12. Operation of AC Adapters Visualized Using Light-Emitting Diodes

    ERIC Educational Resources Information Center

    Regester, Jeffrey

    2016-01-01

    A bridge rectifier is a diamond-shaped configuration of diodes that serves to convert alternating current(AC) into direct current (DC). In our world of AC outlets and DC electronics, they are ubiquitous. Of course, most bridge rectifiers are built with regular diodes, not the light-emitting variety, because LEDs have a number of disadvantages. For…

  13. Display technology - Human factors concepts

    NASA Astrophysics Data System (ADS)

    Stokes, Alan; Wickens, Christopher; Kite, Kirsten

    1990-03-01

    Recent advances in the design of aircraft cockpit displays are reviewed, with an emphasis on their applicability to automobiles. The fundamental principles of display technology are introduced, and individual chapters are devoted to selective visual attention, command and status displays, foveal and peripheral displays, navigational displays, auditory displays, color and pictorial displays, head-up displays, automated systems, and dual-task performance and pilot workload. Diagrams, drawings, and photographs of typical displays are provided.

  14. A liquid-crystal-on-silicon color sequential display using frame buffer pixel circuits

    NASA Astrophysics Data System (ADS)

    Lee, Sangrok

    Next generation liquid-crystal-on-silicon (LCOS) high definition (HD) televisions and image projection displays will need to be low-cost and high quality to compete with existing systems based on digital micromirror devices (DMDs), plasma displays, and direct view liquid crystal displays. In this thesis, a novel frame buffer pixel architecture that buffers data for the next image frame while displaying the current frame, offers such a competitive solution is presented. The primary goal of the thesis is to demonstrate the LCOS microdisplay architecture for high quality image projection displays and at potentially low cost. The thesis covers four main research areas: new frame buffer pixel circuits to improve the LCOS performance, backplane architecture design and testing, liquid crystal modes for the LCOS microdisplay, and system integration and demonstration. The design requirements for the LCOS backplane with a 64 x 32 pixel array are addressed and measured electrical characteristics matches to computer simulation results. Various liquid crystal (LC) modes applicable for LCOS microdisplays and their physical properties are discussed. One- and two-dimensional director simulations are performed for the selected LC modes. Test liquid crystal cells with the selected LC modes are made and their electro-optic effects are characterized. The 64 x 32 LCOS microdisplays fabricated with the best LC mode are optically tested with interface circuitry. The characteristics of the LCOS microdisplays are summarized with the successful demonstration.

  15. Determining minimal display element requirements for surface map displays

    DOT National Transportation Integrated Search

    2003-04-14

    There is a great deal of interest in developing electronic surface map displays to enhance safety and reduce incidents and incursions on or near the airport surface. There is a lack of research, however, detailing the minimal display elements require...

  16. Unified Model of the rf Plasma Sheath, Part II

    NASA Astrophysics Data System (ADS)

    Riley, Merle

    1996-10-01

    By developing an approximation to the first integral of the Poisson equation, one can obtain solutions for the current-voltage characteristics of an rf plasma sheath that are valid over the whole range of inertial response of the ions to an imposed rf voltage or current. (M.E.Riley, 1995 GEC, abstract QA5, published in Bull. Am. Phys. Soc., 40, 1587 (1995).) The theory has been shown to adequately reproduce current-voltage characteristics of two extreme cases (M.A. Lieberman, IEEE Trans. Plasma Sci. 16, 638 (1988). A. Metze, D.W. Ernie, and H.J.Oskam, J.Appl.Phys., 60, 3081 (1986).) of ion response. In this work I show the effect of different conventions for connecting the sheath model to the bulk plasma. Modifications of the Mach number and a finite electric field at the Bohm point are natural choices. The differences are examined for a sheath in a high density Ar plasma and are found to be insignificant. A theoretical argument favors the electric field modification. *Work performed at Sandia National Labs and supported by US DoE under contract DE-AC04-94AL85000.

  17. Adapter-directed display: a modular design for shuttling display on phage surfaces.

    PubMed

    Wang, Kevin Caili; Wang, Xinwei; Zhong, Pingyu; Luo, Peter Peizhi

    2010-02-05

    A novel adapter-directed phage display system was developed with modular features. In this system, the target protein is expressed as a fusion protein consisting of adapter GR1 from the phagemid vector, while the recombinant phage coat protein is expressed as a fusion protein consisting of adapter GR2 in the helper phage vector. Surface display of the target protein is accomplished through specific heterodimerization of GR1 and GR2 adapters, followed by incorporation of the heterodimers into phage particles. A series of engineered helper phages were constructed to facilitate both display valency and formats, based on various phage coat proteins. As the target protein is independent of a specific phage coat protein, this modular system allows the target protein to be displayed on any given phage coat protein and allows various display formats from the same vector without the need for reengineering. Here, we demonstrate the shuttling display of a single-chain Fv antibody on phage surfaces between multivalent and monovalent formats, as well as the shuttling display of an antigen-binding fragment molecule on phage coat proteins pIII, pVII, and pVIII using the same phagemid vectors combined with different helper phage vectors. This adapter-directed display concept has been applied to eukaryotic yeast surface display and to a novel cross-species display that can shuttle between prokaryotic phage and eukaryotic yeast systems. Copyright 2009 Elsevier Ltd. All rights reserved.

  18. The Diagnostics of the External Plasma for the Plasma Rocket

    NASA Technical Reports Server (NTRS)

    Karr, Gerald R.

    1997-01-01

    The plasma rocket is located at NASA Johnson Space Center. To produce a thrust in space. an inert gas is ionized into a plasma and heated in the linear section of a tokamak fusion device to 1 x 10(exp 4) - 1.16 x 10(exp 6)K(p= 10(exp 10) - 10(exp 14)/cu cm ). The magnetic field used to contain the plasma has a magnitude of 2 - 10k Gauss. The plasma plume has a variable thrust and specific impulse. A high temperature retarding potential analyzer (RPA) is being developed to characterize the plasma in the plume and at the edge of the magnetically contained plasma. The RPA measures the energy and density of ions or electrons entering into its solid angle of collection. An oscilloscope displays the ion flux versus the collected current. All measurements are made relative to the facility ground. A RPA is being developed in a process which involves the investigation of several prototypes. The first prototype has been tested on a thermal plasma. The knowledge gained from its development and testing were applied to the development of a RPA for collimated plasma. The prototypes consist of four equally spaced grids and an ion collector. The outermost grid is a ground. The second grid acts as a bias to repel electrons. The third is a variable v voltage ion suppressor. Grid four (inner grid) acts to repel secondary electrons, being biased equal to the first. Knowledge gained during these two stages are being applied to the development of a high temperature RPA Testing of this device involves the determination of its output parameters. sensitivity, and responses to a wide range of energies and densities. Each grid will be tested individually by changing only its voltage and observing the output from the RPA. To verify that the RPA is providing proper output. it is compared to the output from a Langmuir or Faraday probe.

  19. AC Loss Measurements on a 2G YBCO Coil

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rey, Christopher M; Duckworth, Robert C; Schwenterly, S W

    2011-01-01

    The Oak Ridge National Laboratory (ORNL) is collaborating with Waukesha Electric Systems (WES) to continue development of HTS power transformers. For compatibility with the existing power grid, a commercially viable HTS transformer will have to operate at high voltages in the range of 138 kV and above, and will have to withstand 550-kV impulse voltages as well. Second-generation (2G) YBCO coated conductors will be required for an economically-competitive design. In order to adequately size the refrigeration system for these transformers, the ac loss of these HTS coils must be characterized. Electrical AC loss measurements were conducted on a prototype highmore » voltage (HV) coil with co-wound stainless steel at 60 Hz in a liquid nitrogen bath using a lock-in amplifier technique. The prototype HV coil consisted of 26 continuous (without splice) single pancake coils concentrically centered on a stainless steel former. For ac loss measurement purposes, voltage tap pairs were soldered across each set of two single pancake coils so that a total of 13 separate voltage measurements could be made across the entire length of the coil. AC loss measurements were taken as a function of ac excitation current. Results show that the loss is primarily concentrated at the ends of the coil where the operating fraction of critical current is the highest and show a distinct difference in current scaling of the losses between low current and high current regimes.« less

  20. The FL/AC ratio for prediction of shoulder dystocia in women with gestational diabetes.

    PubMed

    Duryea, Elaine L; Casey, Brian M; McIntire, Donald D; Twickler, Diane M

    2017-10-01

    To determine if sonographic variables, including fetal femur length to abdominal circumference (FL/AC) ratio, are associated with shoulder dystocia in women with gestational diabetes. This was a retrospective cohort study of women with gestational diabetes who delivered singleton infants at Parkland Hospital from 1997 to 2015. Diagnosis and treatment of gestational diabetes were uniform including sonography at 32-36 weeks. Biometric calculations were evaluated for correlation with shoulder dystocia. During the study period, 6952 women with gestational diabetes underwent a sonogram at a mean gestation of 34.8 ± 1.8 weeks. Of 4183 vaginal deliveries, 66 experienced shoulder dystocia (16/1000). The FL/AC was associated with shoulder dystocia (p < 0.001) with an AUC of 0.70 (95% CI: 0.64-0.77). This was similar to age-adjusted AC and head circumference to AC ratio (HC/AC) (both with an AUC of 0.72). All other measurements, including estimated fetal weight, were inferior. When examining the 257 women with multiple sonograms after 32 weeks' gestation, FL/AC was stable with advancing gestational age (p = 0.54) whereas age-adjusted AC and HC/AC were not (p < 0.001). The FL/AC is associated with shoulder dystocia in women with gestational diabetes. Additionally, it is a simple ratio that is independent of the reference used and remains stable, unlike age-adjusted AC and HC/AC ratio.

  1. Early function of the Abutilon mosaic virus AC2 gene as a replication brake.

    PubMed

    Krenz, Björn; Deuschle, Kathrin; Deigner, Tobias; Unseld, Sigrid; Kepp, Gabi; Wege, Christina; Kleinow, Tatjana; Jeske, Holger

    2015-04-01

    The C2/AC2 genes of monopartite/bipartite geminiviruses of the genera Begomovirus and Curtovirus encode important pathogenicity factors with multiple functions described so far. A novel function of Abutilon mosaic virus (AbMV) AC2 as a replication brake is described, utilizing transgenic plants with dimeric inserts of DNA B or with a reporter construct to express green fluorescent protein (GFP). Their replicational release upon AbMV superinfection or the individual and combined expression of epitope-tagged AbMV AC1, AC2, and AC3 was studied. In addition, the effects were compared in the presence and in the absence of an unrelated tombusvirus suppressor of silencing (P19). The results show that AC2 suppresses replication reproducibly in all assays and that AC3 counteracts this effect. Examination of the topoisomer distribution of supercoiled DNA, which indicates changes in the viral minichromosome structure, did not support any influence of AC2 on transcriptional gene silencing and DNA methylation. The geminiviral AC2 protein has been detected here for the first time in plants. The experiments revealed an extremely low level of AC2, which was slightly increased if constructs with an intron and a hemagglutinin (HA) tag in addition to P19 expression were used. AbMV AC2 properties are discussed with reference to those of other geminiviruses with respect to charge, modification, and size in order to delimit possible reasons for the different behaviors. The (A)C2 genes encode a key pathogenicity factor of begomoviruses and curtoviruses in the plant virus family Geminiviridae. This factor has been implicated in the resistance breaking observed in agricultural cotton production. AC2 is a multifunctional protein involved in transcriptional control, gene silencing, and regulation of basal biosynthesis. Here, a new function of Abutilon mosaic virus AC2 in replication control is added as a feature of this protein in viral multiplication, providing a novel finding on

  2. Plasma Acceleration by Rotating Magnetic Field Method using Helicon Source

    NASA Astrophysics Data System (ADS)

    Furukawa, Takeru; Shimura, Kaichi; Kuwahara, Daisuke; Shinohara, Shunjiro

    2017-10-01

    Electrodeless plasma thrusters are very promising due to no electrode damage, leading to realize further deep space exploration. As one of the important proposals, we have been concentrating on Rotating Magnetic Field (RMF) acceleration method. High-dense plasma (up to 1013 cm-3) can be generated by using a radio frequency (rf) external antenna, and also accelerated by an antenna wound around outside of a discharge tube. In this scheme, thrust increment is achieved by the axial Lorentz force caused by non linear effects. RMF penetration condition into plasma can be more satisfied than our previous experiment, by increasing RMF coil current and decreasing the RMF frequency, causing higher thrust and fuel efficiency. Measurements of AC RMF component s have been conducted to investigate the acceleration mechanism and the field penetration experimentally. This study has been partially supported by Grant-in-Aid for Scientific Research (B: 17H02995) from the Japan Society for the Promotion of Science.

  3. pH sensing via bicarbonate-regulated “soluble” adenylyl cyclase (sAC)

    PubMed Central

    Rahman, Nawreen; Buck, Jochen; Levin, Lonny R.

    2013-01-01

    Soluble adenylyl cyclase (sAC) is a source of the second messenger cyclic adenosine 3′, 5′ monophosphate (cAMP). sAC is directly regulated by bicarbonate (HCO−3) ions. In living cells, HCO−3 ions are in nearly instantaneous equilibrium with carbon dioxide (CO2) and pH due to the ubiquitous presence of carbonic anhydrases. Numerous biological processes are regulated by CO2, HCO−3, and/or pH, and in a number of these, sAC has been shown to function as a physiological CO2/HCO3/pH sensor. In this review, we detail the known pH sensing functions of sAC, and we discuss two highly-studied, pH-dependent pathways in which sAC might play a role. PMID:24324443

  4. Modeling multi-GeV class laser-plasma accelerators with INF&RNO

    NASA Astrophysics Data System (ADS)

    Benedetti, Carlo; Schroeder, Carl; Bulanov, Stepan; Geddes, Cameron; Esarey, Eric; Leemans, Wim

    2016-10-01

    Laser plasma accelerators (LPAs) can produce accelerating gradients on the order of tens to hundreds of GV/m, making them attractive as compact particle accelerators for radiation production or as drivers for future high-energy colliders. Understanding and optimizing the performance of LPAs requires detailed numerical modeling of the nonlinear laser-plasma interaction. We present simulation results, obtained with the computationally efficient, PIC/fluid code INF&RNO (INtegrated Fluid & paRticle simulatioN cOde), concerning present (multi-GeV stages) and future (10 GeV stages) LPA experiments performed with the BELLA PW laser system at LBNL. In particular, we will illustrate the issues related to the guiding of a high-intensity, short-pulse, laser when a realistic description for both the laser driver and the background plasma is adopted. Work Supported by the U.S. Department of Energy under contract No. DE-AC02-05CH11231.

  5. Measurements of shock-front structure in multi-species plasmas on OMEGA

    NASA Astrophysics Data System (ADS)

    Rinderknecht, Hans G.; Park, H.-S.; Ross, J. S.; Wilks, S. C.; Amendt, P. A.; Heeter, R. F.; Katz, J.; Hoffman, N. M.; Vold, E.; Taitano, W.; Simakov, A.; Chacon, L.

    2016-10-01

    The structure of a shock front in a plasma with multiple ion species is measured for the first time in experiments on the OMEGA laser. Thomson scattering of a 263.25 nm probe beam is used to diagnose electron density, electron and ion temperature, ion species concentration, and flow velocity in strong shocks (M 5) propagating through low-density (ρ 0.1 mg/cc) plasmas composed of H(98%)+Ne(2%) and H(98%)+C(2%). Separation of the ion species within the shock front is inferred. Although shocks play an important role in ICF and astrophysical plasmas, the intrinsically kinetic nature of the shock front indicates the need for experiments to benchmark hydrodynamic models. Comparison with PIC, Vlasov-Fokker-Planck, and multi-component hydrodynamic simulations will be presented. This work performed under auspices of U.S. DOE by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  6. Improved transistorized AC motor controller for battery powered urban electric passenger vehicles

    NASA Technical Reports Server (NTRS)

    Peak, S. C.

    1982-01-01

    An ac motor controller for an induction motor electric vehicle drive system was designed, fabricated, tested, evaluated, and cost analyzed. A vehicle performance analysis was done to establish the vehicle tractive effort-speed requirements. These requirements were then converted into a set of ac motor and ac controller requirements. The power inverter is a three-phase bridge using power Darlington transistors. The induction motor was optimized for use with an inverter power source. The drive system has a constant torque output to base motor speed and a constant horsepower output to maximum speed. A gear shifting transmission is not required. The ac controller was scaled from the base 20 hp (41 hp peak) at 108 volts dec to an expanded horsepower and battery voltage range. Motor reversal was accomplished by electronic reversal of the inverter phase sequence. The ac controller can also be used as a boost chopper battery charger. The drive system was tested on a dynamometer and results are presented. The current-controlled pulse width modulation control scheme yielded improved motor current waveforms. The ac controller favors a higher system voltage.

  7. System and method for determining stator winding resistance in an AC motor using motor drives

    DOEpatents

    Lu, Bin; Habetler, Thomas G; Zhang, Pinjia

    2013-02-26

    A system and method for determining the stator winding resistance of AC motors is provided. The system includes an AC motor drive having an input connectable to an AC source and an output connectable to an input terminal of an AC motor, a pulse width modulation (PWM) converter having switches therein to control current flow and terminal voltages in the AC motor, and a control system connected to the PWM converter. The control system generates a command signal to cause the PWM converter to control an output of the AC motor drive corresponding to an input to the AC motor, selectively generates a modified command signal to cause the PWM converter to inject a DC signal into the output of the AC motor drive, and determines a stator winding resistance of the AC motor based on the DC signal of at least one of the voltage and current.

  8. System status display information

    NASA Technical Reports Server (NTRS)

    Summers, L. G.; Erickson, J. B.

    1984-01-01

    The system Status Display is an electronic display system which provides the flight crew with enhanced capabilities for monitoring and managing aircraft systems. Guidelines for the design of the electronic system displays were established. The technical approach involved the application of a system engineering approach to the design of candidate displays and the evaluation of a Hernative concepts by part-task simulation. The system engineering and selection of candidate displays are covered.

  9. Evolutionary clade affects resistance of Clostridium difficile spores to Cold Atmospheric Plasma

    NASA Astrophysics Data System (ADS)

    Connor, Mairéad; Flynn, Padrig B.; Fairley, Derek J.; Marks, Nikki; Manesiotis, Panagiotis; Graham, William G.; Gilmore, Brendan F.; McGrath, John W.

    2017-02-01

    Clostridium difficile is a spore forming bacterium and the leading cause of colitis and antibiotic associated diarrhoea in the developed world. Spores produced by C. difficile are robust and can remain viable for months, leading to prolonged healthcare-associated outbreaks with high mortality. Exposure of C. difficile spores to a novel, non-thermal atmospheric pressure gas plasma was assessed. Factors affecting sporicidal efficacy, including percentage of oxygen in the helium carrier gas admixture, and the effect on spores from different strains representing the five evolutionary C. difficile clades was investigated. Strains from different clades displayed varying resistance to cold plasma. Strain R20291, representing the globally epidemic ribotype 027 type, was the most resistant. However all tested strains displayed a ~3 log reduction in viable spore counts after plasma treatment for 5 minutes. Inactivation of a ribotype 078 strain, the most prevalent clinical type seen in Northern Ireland, was further assessed with respect to surface decontamination, pH, and hydrogen peroxide concentration. Environmental factors affected plasma activity, with dry spores without the presence of organic matter being most susceptible. This study demonstrates that cold atmospheric plasma can effectively inactivate C. difficile spores, and highlights factors that can affect sporicidal activity.

  10. Improved Tribological Performance of Amorphous Carbon (a-C) Coating by ZrO₂ Nanoparticles.

    PubMed

    Tang, Jinzhu; Ding, Qi; Zhang, Songwei; Wu, Guizhi; Hu, Litian

    2016-09-22

    Nanomaterials, such as Graphene, h-BN nanoparticles and MoS₂ nanotubes, have shown their ability in improving the tribological performance of amorphous carbon (a-C) coatings. In the current study, the effectiveness of ZrO₂ nanoparticles (ZrO₂-NPs) in lubricating the self-mated nonhydrogenated a-C contacts was investigated in boundary lubrication regime. The results showed that 13% less friction and 50% less wear compared to the base oil were achieved by employing ZrO₂-NPs in the base oil in self-mated a-C contacts. Via analyzing the ZrO₂-NPs and the worn a-C surface after tests, it was found that the improved lubrication by ZrO₂-NPs was based on "polishing effects", which is a new phenomenon observed between a-C and nanoparticles. Under the "polishing effect", micro-plateaus with extremely smooth surface and uniform height were produced on the analyzed a-C surface. The resulting topography of the a-C coating is suitable for ZrO₂-NPs to act as nano-bearings between rubbing surfaces. Especially, the ZrO₂-NPs exhibited excellent mechanical and chemical stability, even under the severe service condition, suggesting that the combination of nonhydrogenated a-C coating with ZrO₂-NPs is an effective, long lasting and environment-friendly lubrication solution.

  11. Low-frequency, self-sustained oscillations in inductively coupled plasmas used for optical pumping

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coffer, J.; Encalada, N.; Huang, M.

    We have investigated very low frequency, on the order of one hertz, self-pulsing in alkali-metal inductively-coupled plasmas (i.e., rf-discharge lamps). This self-pulsing has the potential to significantly vary signal-to-noise ratios and (via the ac-Stark shift) resonant frequencies in optically pumped atomic clocks and magnetometers (e.g., the atomic clocks now flying on GPS and Galileo global navigation system satellites). The phenomenon arises from a nonlinear interaction between the atomic physics of radiation trapping and the plasma's electrical nature. To explain the effect, we have developed an evaporation/condensation theory (EC theory) of the self-pulsing phenomenon.

  12. Global Modeling of Uranium Molecular Species Formation Using Laser-Ablated Plasmas

    NASA Astrophysics Data System (ADS)

    Curreli, Davide; Finko, Mikhail; Azer, Magdi; Armstrong, Mike; Crowhurst, Jonathan; Radousky, Harry; Rose, Timothy; Stavrou, Elissaios; Weisz, David; Zaug, Joseph

    2016-10-01

    Uranium is chemically fractionated from other refractory elements in post-detonation nuclear debris but the mechanism is poorly understood. Fractionation alters the chemistry of the nuclear debris so that it no longer reflects the chemistry of the source weapon. The conditions of a condensing fireball can be simulated by a low-temperature plasma formed by vaporizing a uranium sample via laser heating. We have developed a global plasma kinetic model in order to model the chemical evolution of U/UOx species within an ablated plasma plume. The model allows to track the time evolution of the density and energy of an uranium plasma plume moving through an oxygen atmosphere of given fugacity, as well as other relevant quantities such as average electron and gas temperature. Comparison of model predictions with absorption spectroscopy of uranium-ablated plasmas provide preliminary insights on the key chemical species and evolution pathways involved during the fractionation process. This project was sponsored by the DoD, Defense Threat Reduction Agency, Grant HDTRA1-16-1-0020. This work was performed in part under the auspices of the U.S. DoE by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  13. Negative hydrogen ions in a linear helicon plasma device

    NASA Astrophysics Data System (ADS)

    Corr, Cormac; Santoso, Jesse; Samuell, Cameron; Willett, Hannah; Manoharan, Rounak; O'Byrne, Sean

    2015-09-01

    Low-pressure negative ion sources are of crucial importance to the development of high-energy (>1 MeV) neutral beam injection systems for the ITER experimental tokamak device. Due to their high power coupling efficiency and high plasma densities, helicon devices may be able to reduce power requirements and potentially remove the need for caesium. In helicon sources, the RF power can be coupled efficiently into the plasma and it has been previously observed that the application of a small magnetic field can lead to a significant increase in the plasma density. In this work, we investigate negative ion dynamics in a high-power (20 kW) helicon plasma source. The negative ion fraction is measured by probe-based laser photodetachment, electron density and temperature are determined by a Langmuir probe and tuneable diode laser absorption spectroscopy is used to determine the density of the H(n = 2) excited atomic state and the gas temperature. The negative ion density and excited atomic hydrogen density display a maximum at a low applied magnetic field of 3 mT, while the electron temperature displays a minimum. The negative ion density can be increased by a factor of 8 with the application of the magnetic field. Spatial and temporal measurements will also be presented. The Australian Research Grants Council is acknowledged for funding.

  14. Dielectrophoretic particle-particle interaction under AC electrohydrodynamic flow conditions.

    PubMed

    Lee, Doh-Hyoung; Yu, Chengjie; Papazoglou, Elisabeth; Farouk, Bakhtier; Noh, Hongseok M

    2011-09-01

    We used the Maxwell stress tensor method to understand dielectrophoretic particle-particle interactions and applied the results to the interpretation of particle behaviors under alternating current (AC) electrohydrodynamic conditions such as AC electroosmosis (ACEO) and electrothermal flow (ETF). Distinct particle behaviors were observed under ACEO and ETF. Diverse particle-particle interactions observed in experiments such as particle clustering, particles keeping a certain distance from each other, chain and disc formation and their rotation, are explained based on the numerical simulation data. The improved understanding of particle behaviors in AC electrohydrodynamic flows presented here will enable researchers to design better particle manipulation strategies for lab-on-a-chip applications. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Promising efficacy of novel BTK inhibitor AC0010 in mantle cell lymphoma.

    PubMed

    Yan, Xiao; Zhou, Yile; Huang, Shujuan; Li, Xia; Yu, Mengxia; Huang, Jiansong; Wang, Jinghan; Ma, Zhixin; Jin, Jingrui; Pan, Jiajia; Li, Chenying; Li, Fenglin; Jin, Jie

    2018-04-01

    We researched into the effect and mechanism of AC0010, a novel BTK inhibitor, in MCL, and compared its efficacy and safety with Ibrutinib to develop a preclinical study for the future therapy of MCL. MTS assay was used to detect the growth inhibition caused by AC0010 and Ibrutinib, respectively, in MCL cell lines (Jeko-1 and JVM-2), primary MCL cells, and normal peripheral lymphocytes. Apoptosis of Jeko-1 and JVM-2 after exposure into AC0010 and Ibrutinib was conducted by flow cytometry; the expression of apoptosis-related proteins was checked by Western blot. q-PCR and Western blot were applied to examine the expression of BTK and p-BTK at mRNA and protein level as well as the BTK-ralated signaling pathways. MCL xenograft was developed to testify the efficacy and safety of AC0010 in vivo. In contrast with Ibrutinib, AC0010 proved to be more toxic to MCL cells in vitro (p < 0.01) with no augment in cytotoxicity to normal peripheral lymphocytes, and it can induce obvious apoptosis in MCL cell lines (p < 0.01) through caspase family and Bcl-2 family. AC0010 at 300 mg/kg can prolong the survival rate in MCL xenograft (p < 0.01). The phosphorylation of BTK is inhibited by AC0010 following simultaneously inhibition of BCR-BTK and PI3K/AKT signaling pathway in MCL cells. AC0010 is a novel BTK inhibitor of great efficacy and safety in MCL.

  16. AC to DC Bridgeless Boost Converter for Ultra Low Input Energy Harvesting

    NASA Astrophysics Data System (ADS)

    Dawam, A. H. A.; Muhamad, M.

    2018-03-01

    This paper presents design of circuit which converts low input AC voltage to a higher output DC voltage. A buck-boost topology and boost topology are combined to condition cycle of an AC input voltage. the unique integration of a combining circuit of buck-boost and boost circuit have been proposed in order to introduce a new direct ac-dc power converter topology without conventional diode bridge rectifier. The converter achieved to convert a milli-volt scale of input AC voltage into a volt scale of output DC voltages which is from 400mV to 3.3V.

  17. Analytical theory and possible detection of the ac quantum spin Hall effect

    DOE PAGES

    Deng, W. Y.; Ren, Y. J.; Lin, Z. X.; ...

    2017-07-11

    Here, we develop an analytical theory of the low-frequency ac quantum spin Hall (QSH) effect based upon the scattering matrix formalism. It is shown that the ac QSH effect can be interpreted as a bulk quantum pumping effect. When the electron spin is conserved, the integer-quantized ac spin Hall conductivity can be linked to the winding numbers of the reflection matrices in the electrodes, which also equal to the bulk spin Chern numbers of the QSH material. Furthermore, a possible experimental scheme by using ferromagnetic metals as electrodes is proposed to detect the topological ac spin current by electrical means.

  18. The Hubble Legacy Archive ACS grism data

    NASA Astrophysics Data System (ADS)

    Kümmel, M.; Rosati, P.; Fosbury, R.; Haase, J.; Hook, R. N.; Kuntschner, H.; Lombardi, M.; Micol, A.; Nilsson, K. K.; Stoehr, F.; Walsh, J. R.

    2011-06-01

    A public release of slitless spectra, obtained with ACS/WFC and the G800L grism, is presented. Spectra were automatically extracted in a uniform way from 153 archival fields (or "associations") distributed across the two Galactic caps, covering all observations to 2008. The ACS G800L grism provides a wavelength range of 0.55-1.00 μm, with a dispersion of 40 Å/pixel and a resolution of ~80 Å for point-like sources. The ACS G800L images and matched direct images were reduced with an automatic pipeline that handles all steps from archive retrieval, alignment and astrometric calibration, direct image combination, catalogue generation, spectral extraction and collection of metadata. The large number of extracted spectra (73,581) demanded automatic methods for quality control and an automated classification algorithm was trained on the visual inspection of several thousand spectra. The final sample of quality controlled spectra includes 47 919 datasets (65% of the total number of extracted spectra) for 32 149 unique objects, with a median iAB-band magnitude of 23.7, reaching 26.5 AB for the faintest objects. Each released dataset contains science-ready 1D and 2D spectra, as well as multi-band image cutouts of corresponding sources and a useful preview page summarising the direct and slitless data, astrometric and photometric parameters. This release is part of the continuing effort to enhance the content of the Hubble Legacy Archive (HLA) with highly processed data products which significantly facilitate the scientific exploitation of the Hubble data. In order to characterize the slitless spectra, emission-line flux and equivalent width sensitivity of the ACS data were compared with public ground-based spectra in the GOODS-South field. An example list of emission line galaxies with two or more identified lines is also included, covering the redshift range 0.2 - 4.6. Almost all redshift determinations outside of the GOODS fields are new. The scope of science projects

  19. A MEMS sensor for AC electric current

    NASA Astrophysics Data System (ADS)

    Leland, Eli Sidney

    This manuscript describes the development of a new MEMS sensor for the measurement of AC electric current. The sensor is comprised of a MEMS piezoelectric cantilever with a microscale permanent magnet mounted to the cantilever's free end. When placed near a wire carrying AC current, the magnet couples to the oscillating magnetic field surrounding the wire, causing the cantilever to deflect, and piezoelectric coupling produces a sinusoidal voltage proportional to the current in the wire. The sensor is itself passive, requiring no power supply to operate. It also operates on proximity and need only be placed near a current carrier in order to function. The sensor does not need to encircle the current carrier and it therefore can measure current in two-wire zip-cords without necessitating the separation of the two conductors. Applications for tins sensor include measuring residential and commercial electricity use and monitoring electric power distribution networks. An analytical model describing the behavior of the current sensor was developed. This model was also adapted to describe the power output of an energy scavenger coupled to a wire carrying AC current. A mesoscale sensor exhibited a sensitivity of 75 mV/A when measuring AC electric current in a zip-cord. A mesoscale energy scavenger produced 345 muW when coupled to a zip-cord carrying 13 A. MEMS current sensors were fabricated from aluminum nitride piezoelectric cantilevers and composite permanent magnets. The cantilevers were fabricated using a four-mask process. Microscale permanent magnets were dispenser-printed using NdFeB magnetic powder with an epoxy binder. The MEMS AC current sensor was interfaced with amplification circuitry and packaged inside an almninum enclosure. The sensor was also integrated with a mesoscale energy scavenger and power conditioning circuitry to create a fully self-powered current sensor. Unamplified sensitivity of the sensor was 0.1-1.1 mV/A when measuring currents in single

  20. The reaction of chlorobenzene with plasma of H2O, CO2 and CH4 obtained by an alternating-current plasma torch with a vortex stabilization

    NASA Astrophysics Data System (ADS)

    Surov, A. V.; Subbotin, D. I.; Obraztsov, N. V.; Popov, S. D.; Popov, V. E.; Litvyakova, A. I.; Pavlov, A. V.; Serba, E. O.; Spodobin, V. A.; Nakonechny, Gh V.

    2018-01-01

    This paper presents the three-phase ac plasma torch with a vortex stabilization of the arc, and two inputs of plasma environments: the electrode zone and the arc zone. Shielding gas (carbon dioxide) is supplied in the electrode zone and steam, methane and vapor of chlorobenzene are fed in the arc zone. By means of it the life time of electrodes is increased significantly. Chlorobenzene is selected, as it is the simplest aromatic chlorine-containing substance. The chemical process flows in two pathways: the formation of synthesis gas and the formation of soot. The gaseous chlorine-containing compound was only hydrogen chloride, yield of soot was 0.98% by weight of the raw materials, and the chlorine content was 2.08 wt% by the soot.

  1. The diagnosis of high altitude illness by the determination of plasma dermcidin isoform 2 levels by enzyme linked immunosorbent assay.

    PubMed

    Bank, Sarbashri; Ghosh, Rajeshwary; Jana, Pradipta; Bhattacharya, Suman; Sinha, Asru K

    2014-01-01

    High altitude illness (HAI) is a cluster of syndromes which develops due to the injury of the central nervous system produced by the reduction of the partial pressure of O2 in the atmosphere which disappears on decent. The HAI also results in a prothrombotic condition leading to acute coronary syndrome (ACS), which cannot be controlled on descent to the ground level. There is no diagnosis in HAI to forewarn of the impending ACS. A protein identified to be dermcidin isoform 2 (dermcidin), produced in the system due to environmental stresses, has been reported to be a potent diabetogenic agent. Investigation was carried out to determine the systemic stimulation of dermcidin synthesis at different levels of altitudes in normal adult male volunteers to assess the feasibility of developing a diagnosis for ACS in HAI due to dermcidin synthesis. Normal, nondiabetic, normotensive male volunteers (25 - 35 years old, n = 16) participated in the study. The plasma dermcidin level was determined by enzyme linked immunosorbent assay (ELISA) and by in vitro translation of dermcidin mRNA. The plasma insulin level was determined by ELISA and blood glucose level was determined in a glucometer (Behringer). The plasma dermcidin level in the volunteers at ground level was 10 +/- 2.10 nM and increased to 80 +/- 4.62 nM at 15000 feet altitude. For each 1000 feet increase of altitude, the dermcidin level increased by 5.83 +/- 0.21 nM with a Coefficient of Correlation "r" = +0.9405. The increase of plasma dermcidin level was found to be inversely related to the decrease of plasma insulin level from 23 microunit/mL to 5 microunit/mL from sea level to 15000 feet height ("r" = -0.9951) with concomitant increase of blood sugar level from 80 +/- 3.6 mg/dL to 135 +/- 2.01 mg/dL. These results suggest the feasibility of a diagnosis of a prediabetic condition by determining the plasma dermcidin level in HAI by simple ELISA which may also be useful to forewarn of the possibility of developing an

  2. On-Chip AC self-test controller

    DOEpatents

    Flanagan, John D [Rhinebeck, NY; Herring, Jay R [Poughkeepsie, NY; Lo, Tin-Chee [Fishkill, NY

    2009-09-29

    A system for performing AC self-test on an integrated circuit that includes a system clock for normal operation is provided. The system includes the system clock, self-test circuitry, a first and second test register to capture and launch test data in response to a sequence of data pulses, and a logic circuit to be tested. The self-test circuitry includes an AC self-test controller and a clock splitter. The clock splitter generates the sequence of data pulses including a long data capture pulse followed by an at speed data launch pulse and an at speed data capture pulse followed by a long data launch pulse. The at speed data launch pulse and the at speed data capture pulse are generated for a common cycle of the system clock.

  3. Sensitivity of RF-driven Plasma Filaments to Trace Gases

    NASA Astrophysics Data System (ADS)

    Burin, M. J.; Czarnocki, C. J.; Czarnocki, K.; Zweben, S. J.; Zwicker, A.

    2011-10-01

    Filamentary structures have been observed in many types of plasma discharges in both natural (e.g. lightning) and industrial systems (e.g. dielectric barrier discharges). Recent progress has been made in characterizing these structures, though various aspects of their essential physics remain unclear. A common example of this phenomenon can be found within a toy plasma globe (or plasma ball), wherein a primarily neon gas mixture near atmospheric pressure clearly and aesthetically displays filamentation. Recent work has provided the first characterization of these plasma globe filaments [Campanell et al., Physics of Plasmas 2010], where it was noticed that discharges of pure gases tend not to produce filaments. We have extended this initial work to investigate in greater detail the dependence of trace gases on filamentation within a primarily Neon discharge. Our preliminary results using a custom globe apparatus will be presented, along with some discussion of voltage dependencies. Newly supported by the NSF/DOE Partnership in Basic Plasma Science and Engineering.

  4. The Use of AC-DC-AC Methods in Assessing Corrosion Resistance Performance of Coating Systems for Magnesium Alloys

    NASA Astrophysics Data System (ADS)

    McCune, Robert C.; Upadhyay, Vinod; Wang, Yar-Ming; Battocchi, Dante

    The potential utility of AC-DC-AC electrochemical methods in comparative measures of corrosion-resisting coating system performance for magnesium alloys under consideration for the USAMP "Magnesium Front End Research and Development" project was previously shown in this forum [1]. Additional studies of this approach using statistically-designed experiments have been conducted with focus on alloy types, pretreatment, topcoat material and topcoat thickness as the variables. Additionally, sample coupons made for these designed experiments were also subjected to a typical automotive cyclic corrosion test cycle (SAE J2334) as well as ASTM B117 for comparison of relative performance. Results of these studies are presented along with advantages and limitations of the proposed methodology.

  5. Liquid Crystal Airborne Display

    DTIC Science & Technology

    1977-08-01

    Cum.nings, J. P., et al., Properties and Limitations oe Liquid Crystals for Aircraft Displays, Honeywell Corporate Researc ."I Center, Final Report HR-72...basic module could be used to build displays for both the commercial and military! 157- marhecs, and so would establi sh a broad and sizable market ... market for the display becomes a reality; therein lies, f TABLE 16 THE COURSE OF FUTURE DISPLAY DEVELOPMENT Today 1976-77 1980 1985 Display Size 2" 1 3.2

  6. Cytoplasmic bacteriophage display system

    DOEpatents

    Studier, F.W.; Rosenberg, A.H.

    1998-06-16

    Disclosed are display vectors comprising DNA encoding a portion of a structural protein from a cytoplasmic bacteriophage, joined covalently to a protein or peptide of interest. Exemplified are display vectors wherein the structural protein is the T7 bacteriophage capsid protein. More specifically, in the exemplified display vectors the C-terminal amino acid residue of the portion of the capsid protein is joined to the N-terminal residue of the protein or peptide of interest. The portion of the T7 capsid protein exemplified comprises an N-terminal portion corresponding to form 10B of the T7 capsid protein. The display vectors are useful for high copy number display or lower copy number display (with larger fusion). Compositions of the type described herein are useful in connection with methods for producing a virus displaying a protein or peptide of interest. 1 fig.

  7. Cytoplasmic bacteriophage display system

    DOEpatents

    Studier, F. William; Rosenberg, Alan H.

    1998-06-16

    Disclosed are display vectors comprising DNA encoding a portion of a structural protein from a cytoplasmic bacteriophage, joined covalently to a protein or peptide of interest. Exemplified are display vectors wherein the structural protein is the T7 bacteriophage capsid protein. More specifically, in the exemplified display vectors the C-terminal amino acid residue of the portion of the capsid protein is joined to the N-terminal residue of the protein or peptide of interest. The portion of the T7 capsid protein exemplified comprises an N-terminal portion corresponding to form 10B of the T7 capsid protein. The display vectors are useful for high copy number display or lower copy number display (with larger fusion). Compositions of the type described herein are useful in connection with methods for producing a virus displaying a protein or peptide of interest.

  8. Superconducting shielded core reactor with reduced AC losses

    DOEpatents

    Cha, Yung S.; Hull, John R.

    2006-04-04

    A superconducting shielded core reactor (SSCR) operates as a passive device for limiting excessive AC current in a circuit operating at a high power level under a fault condition such as shorting. The SSCR includes a ferromagnetic core which may be either closed or open (with an air gap) and extends into and through a superconducting tube or superconducting rings arranged in a stacked array. First and second series connected copper coils each disposed about a portion of the iron core are connected to the circuit to be protected and are respectively wound inside and outside of the superconducting tube or rings. A large impedance is inserted into the circuit by the core when the shielding capability of the superconducting arrangement is exceeded by the applied magnetic field generated by the two coils under a fault condition to limit the AC current in the circuit. The proposed SSCR also affords reduced AC loss compared to conventional SSCRs under continuous normal operation.

  9. Scanning AC Nanocalorimetry and Its Applications

    NASA Astrophysics Data System (ADS)

    Xiao, Kechao

    This thesis presents an AC nanocalorimetry technique that enables calorimetry measurements on very small quantities of materials over a wide range of scanning rates (from isothermal to 3x10. 3 K/s), temperatures(up to 1200 K), and environments. Such working range bridges the gap between traditional scanning calorimetry of bulk materials and nanocalorimetry. The method relies on a micromachined nanocalorimeter with negligible thermal lags between heater, thermometer, and sample. The ability to perform calorimetry measurements over such a broad range of scanning rates makes it an ideal tool to characterize the kinetics of phase transformations, reactions at elevated temperatures or to explore the behavior of materials far from equilibrium. We demonstrate the technique by performing measurements on thin-film samples of Sn, In, and Bi with thicknesses ranging from 100 to 300 nm. The experimental heat capacities and melting temperatures agree well with literature values. The measured heat capacities are insensitive to the applied AC frequency, scan rate, and heat loss to the environment over a broad range of experimental conditions. The dynamic range of scanning AC nanocalorimetry enables the combination of nanocalorimetry with in-situ x-ray diffraction (XRD) to facilitate interpretation of the calorimetry measurements. Time-resolved XRD during in-situ operation of nanocalorimetry sensors using intense, high-energy synchrotron radiation allows unprecedented characterization of thermal and structural material properties. We demonstrate this experiment with detailed characterization of the melting and solidification of elemental Bi, In and Sn thin-film samples, using heating and cooling rates up to 300 K/s. By combining scanning DC and AC nano-calorimetry techniques, we study the nucleation behavior of undercooled liquid Bi at cooling rates ranging from 10. 1 to 10. 4 K/s. Upon initial melting, the Bi thin-film sample breaksup into isolated islands. The number of islands

  10. Roebel assembled coated conductor cables (RACC): Ac-Losses and current carrying potential

    NASA Astrophysics Data System (ADS)

    Frank, A.; Heller, R.; Goldacker, W.; Kling, A.; Schmidt, C.

    2008-02-01

    Low ac-loss HTS cables for transport currents well above 1 kA are required for application in transformers and generators and are taken into consideration for future generations of fusion reactor coils. Coated conductors (CC) are suitable candidates for high field application at an operation temperature in the range 50-77 K. Ac-field applications require cables with low ac-losses and hence twisting of the individual strands. We solved this problem using the Roebel technique. Short lengths of Roebel bar cables were prepared from industrial DyBCO and YBCO-CC. Meander shaped tapes of 4 or 5 mm width with twist pitches of 123 or 127 mm were cut from the 10 or 12 mm wide CC tapes using a specially designed tool. Eleven or twelve of these strands were assembled to a cable. The electrical and mechanical connection of the tapes was achieved using a silver powder filled conductive epoxy resin. Ac-losses of a short sample in an external ac-field were measured as a function of frequency and field amplitude as well as the coupling current decay time constant. We discuss the results in terms of available theories and compare measured time constants in transverse field with measured coupling losses. Finally the potential of this cable type for ac-use is discussed with respect to ac-losses and current carrying capability.

  11. Characterization of boronized graphite in NSTX-U and its effect on plasma performance

    NASA Astrophysics Data System (ADS)

    Bedoya, Felipe; Allain, Jean Paul; Kaita, Robert; Skinner, Charles; University of Illinois Team; Princeton Plasma Physics Laboratory Collaboration

    2017-10-01

    Plasma Facing Components (PFC) conditioning can have a crucial influence in plasma performance in tokamak machines. The National Spherical Torus Experiment (NSTX-U) used boronization as the main wall conditioning technique during the FY16 experimental campaign. The Materials Analysis Particle Probe (MAPP), a characterization facility, was used to investigate the surface of ATJ graphite exposed to boronization and plasma in the tokamak using X-ray Photoelectron Spectroscopy (XPS). The measurements showed that plasma induced oxidation plays a critical role in the chemical evolution of the surfaces and as a consequence in plasma performance. Additionally, ex-vessel in-situ laboratory experiments and post-mortem studies of extracted NSTX-U tiles were performed to complement the observations made with MAPP, including controlled D irradiations and XPS depth profiles. These three methodologies show congruent results where D exposures increase the oxygen concentration between 20-30%, highlighting the influence of these two species on the chemistry of the samples. USDOE Contract DE-AC02-09CH11466, USDOE Contract DE-SC0010717 and Award Number DE-SC0012890.

  12. Cell lines, Md108 and Md66, from the hemocytes of Malacosoma disstria (Lepidoptera) display aspects of plasma-free innate non-self activities.

    PubMed

    Lapointe, Jason F; Dunphy, Gary B; Giannoulis, Paschalis; Mandato, Craig A; Nardi, James B; Gharib, Osama H; Niven, Donald F

    2011-11-01

    The innate non-self response systems of the deciduous tree pest, the forest tent caterpillar, Malacosoma disstria has been documented by us in terms of in vitro and in vivo reactions towards the Gram-positive nonpathogenic bacterium, Bacillus subtilis and Gram-negative pathogenic microbe, Xenorhabdus nematophila and their respective surface antigens, lipopoteichoic acids (LTA) and lipopolysaccharides (LPS). These studies, often conducted in whole and diluted hemolymph, preclude examination of plasma-free cellular (hemocyte) responses. Plasma-free hemocytes as primary cultures are difficult to obtain. The floating cell line Md66 and attached cell line Md108 from M. disstria hemocytes were examined as a model for plasma-free M. disstria hemocyte non-self responses. Herein, it was established that although both lines differed from each other and from the primary hemocyte cultures of M. disstria in growth parameters, cell composition and sizes both cell lines displayed granular cell-like (GL) cells and plasmatocyte-like (PL) cells according to morphological criteria and to some extent antigenic similarities based on labeling with anti-Chrysodeixis includens hemocyte monoclonal antibodies. Hemocyte-specific neuroglian-like protein was detected on cells of both cell lines and in the primary hemocyte cultures albeit with staining patterns differing according to culture and cell types, confluency levels and cell-cell adhesion. Both cell lines bound B. subtilis and X. nematophila, the reaction extent varying with the cell line and its cell types. LPS damaged both cell types in the two cell lines whereas LTA enhanced the adhesion of Md66 GL cells to flask surfaces followed by PL cell adhesion. PL cells of both lines, like the primary cultures, phagocytosed FITC-labeled B. subtilis; only Md108 GL cells phagocytosed B. subtilis. In either case phagocytosis was always less in frequency and intensity than the primary cultures. Proteins released from the cell lines differed in

  13. Pulse Front Tilt and Laser Plasma Acceleration

    NASA Astrophysics Data System (ADS)

    Mittelberger, Daniel; Thévenet, Maxence; Nakamura, Kei; Lehe, Remi; Gonsalves, Anthony; Benedetti, Carlo; Leemans, Wim

    2017-10-01

    Pulse front tilt (PFT) is potentially present in any CPA laser system, but its effects may be overlooked because spatiotemporal pulse characterization is considerably more involved than measuring only spatial or temporal profile. PFT is particularly important for laser plasma accelerators (LPA) because it influences electron beam injection and steering. In this work, experimental results from the BELLA Center will be presented that demonstrate the effect of optical grating misalignment and optical compression, resulting in PFT, on accelerator performance. Theoretical models of laser and electron beam steering will be introduced based on particle-in-cell simulations showing distortion of the plasma wake. Theoretical predictions will be compared with experiments and complimentary simulations, and tolerances on PFT and optical compressor alignment will be developed as a function of LPA performance requirements. This work was supported by the Office of High Energy Physics, Office of Science, US Department of Energy under Contract DE-AC02-05CH11231 and the National Science Foundation under Grant PHY-1415596.

  14. Studies of Particle Wake Potentials in Plasmas

    NASA Astrophysics Data System (ADS)

    Ellis, Ian; Graziani, Frank; Glosli, James; Strozzi, David; Surh, Michael; Richards, David; Decyk, Viktor; Mori, Warren

    2011-10-01

    Fast Ignition studies require a detailed understanding of electron scattering, stopping, and energy deposition in plasmas with variable values for the number of particles within a Debye sphere. Presently there is disagreement in the literature concerning the proper description of these processes. Developing and validating proper descriptions requires studying the processes using first-principle electrostatic simulations and possibly including magnetic fields. We are using the particle-particle particle-mesh (PPPM) code ddcMD and the particle-in-cell (PIC) code BEPS to perform these simulations. As a starting point in our study, we examine the wake of a particle passing through a plasma in 3D electrostatic simulations performed with ddcMD and with BEPS using various cell sizes. In this poster, we compare the wakes we observe in these simulations with each other and predictions from Vlasov theory. Prepared by LLNL under Contract DE-AC52-07NA27344 and by UCLA under Grant DE-FG52-09NA29552.

  15. Real-time and post-plasma studies of influence of low levels of tungsten on carbon erosion and surface evolution behaviour in D2 plasma

    NASA Astrophysics Data System (ADS)

    Weilnboeck, F.; Fox-Lyon, N.; Oehrlein, G. S.; Doerner, R. P.

    2010-02-01

    A profound influence of monolayer tungsten coverage of hard carbon films on the evolution of carbon surface erosion behaviour, surface chemistry and morphology in D2 plasma has been established by real-time ellipsometry, x-ray photoelectron spectroscopy and atomic force microscopy measurements. The erosion of tungsten-covered carbon showed two distinct stages of plasma material interactions: rapid tungsten removal during the initial erosion period and steady-state amorphous carbon removal accompanied by large-scale surface roughness development. The initial removal of tungsten takes place at a rate that significantly exceeds typical sputter yields at the ion energies used here and is attributed to elimination of weakly bonded tungsten from the surface. The tungsten remaining on the a-C : H film surface causes surface roughness development of the eroding carbon surface by a masking effect, and simultaneously leads to a seven fold reduction of the steady-state carbon erosion rate for long plasma surface interaction times (~100 s). Results presented are of direct relevance for material transport and re-deposition, and the interaction of those films with plasma in the divertor region and on mirror surfaces of fusion devices.

  16. Comparative single-cell genomics reveals potential ecological niches for the freshwater acI Actinobacteria lineage.

    PubMed

    Ghylin, Trevor W; Garcia, Sarahi L; Moya, Francisco; Oyserman, Ben O; Schwientek, Patrick; Forest, Katrina T; Mutschler, James; Dwulit-Smith, Jeffrey; Chan, Leong-Keat; Martinez-Garcia, Manuel; Sczyrba, Alexander; Stepanauskas, Ramunas; Grossart, Hans-Peter; Woyke, Tanja; Warnecke, Falk; Malmstrom, Rex; Bertilsson, Stefan; McMahon, Katherine D

    2014-12-01

    Members of the acI lineage of Actinobacteria are the most abundant microorganisms in most freshwater lakes; however, our understanding of the keys to their success and their role in carbon and nutrient cycling in freshwater systems has been hampered by the lack of pure cultures and genomes. We obtained draft genome assemblies from 11 single cells representing three acI tribes (acI-A1, acI-A7, acI-B1) from four temperate lakes in the United States and Europe. Comparative analysis of acI SAGs and other available freshwater bacterial genomes showed that acI has more gene content directed toward carbohydrate acquisition as compared to Polynucleobacter and LD12 Alphaproteobacteria, which seem to specialize more on carboxylic acids. The acI genomes contain actinorhodopsin as well as some genes involved in anaplerotic carbon fixation indicating the capacity to supplement their known heterotrophic lifestyle. Genome-level differences between the acI-A and acI-B clades suggest specialization at the clade level for carbon substrate acquisition. Overall, the acI genomes appear to be highly streamlined versions of Actinobacteria that include some genes allowing it to take advantage of sunlight and N-rich organic compounds such as polyamines, di- and oligopeptides, branched-chain amino acids and cyanophycin. This work significantly expands the known metabolic potential of the cosmopolitan freshwater acI lineage and its ecological and genetic traits.

  17. AC magnetic field measurement using a small flip coil system for rapid cycling AC magnets at the China Spallation Neutron Source (CSNS)

    NASA Astrophysics Data System (ADS)

    Zhou, Jianxin; Kang, Wen; Li, Shuai; Liu, Yudong; Liu, Yiqin; Xu, Shouyan; Guo, Xiaoling; Wu, Xi; Deng, Changdong; Li, Li; Wu, Yuwen; Wang, Sheng

    2018-02-01

    The China Spallation Neutron Source (CSNS) has two major accelerator systems, a linear accelerator and a rapid cycling synchrotron (RCS). The RCS accelerator is used to accumulate and accelerate protons from the energy of 80 MeV to the design energy of 1.6 GeV at the repetition rate of 25 Hz, and extract the high energy beam to the target. The main magnets of the RCS accelerator are excited by AC current with DC bias. The magnetic field quality is very important for the RCS accelerator operation, since it should guarantee and focus a circulating beam. In order to characterize the AC magnets, a small flip coil measurement system has been developed and one of each type of AC magnets has been studied. The measurement system and selected measurement results are presented in this paper.

  18. Ion trajectory simulations of axial ac dipolar excitation in the Orbitrap

    NASA Astrophysics Data System (ADS)

    Wu, Guangxiang; Noll, Robert J.; Plass, Wolfgang R.; Hu, Qizhi; Perry, Richard H.; Cooks, R. Graham

    2006-07-01

    The newly developed version of the multi-particle ion trajectory simulation program, ITSIM 6.0, was applied to simulate ac dipolar excitation of ion axial motion in the Orbitrap. The Orbitrap inner and outer electrodes were generated in AutoCAD, a 3D drawing program. The electrode geometry was imported into the 3D field solver COMSOL; the field array was then imported into ITSIM 6.0. Ion trajectories were calculated by solving Newton's equations using Runge-Kutta integration methods. Compared to the analytical solution, calculated radial components of the field at the device's "equator" (z = 0) were within 0.5% and calculated axial components midway between the inner and outer electrodes were within 0.2%. The experiments simulated here involved the control of axial motion of ions in the Orbitrap by the application of dipolar ac signals to the split outer electrodes, as described in a recently published paper from this laboratory [Hu et al., J. Phys. Chem. A 110 (2006) 2682]. In these experiments, ac signal was applied at the axial resonant frequency of a selected ion. Axial excitation and eventual ion ejection resulted when the ac was in phase with, i.e., had 0° phase relative to ion axial motion. De-excitation of ion axial motion until the ions were at z = 0 and at rest with respect to the z-axis resulted if the applied ac was out of phase with ion motion, with re-excitation of ion axial motion occurring if the dipolar ac was continued beyond this point. Both de-excitation and re-excitation could be achieved mass-selectively and depended on the amplitude and duration (number of cycles) of the applied ac. The effects of ac amplitude, frequency, phase relative to ion motion, and bandwidth of applied waveform were simulated. All simulation results were compared directly with the experimental data and good agreement was observed. Such ion motion control experiments and their simulation provide the possibility to improve Orbitrap performance and to develop tandem mass

  19. Liquid Phase Plasma Synthesis of Iron Oxide Nanoparticles on Nitrogen-Doped Activated Carbon Resulting in Nanocomposite for Supercapacitor Applications.

    PubMed

    Lee, Heon; Lee, Won-June; Park, Young-Kwon; Ki, Seo Jin; Kim, Byung-Joo; Jung, Sang-Chul

    2018-03-25

    Iron oxide nanoparticles supported on nitrogen-doped activated carbon powder were synthesized using an innovative plasma-in-liquid method, called the liquid phase plasma (LPP) method. Nitrogen-doped carbon (NC) was prepared by a primary LPP reaction using an ammonium chloride reactant solution, and an iron oxide/NC composite (IONCC) was prepared by a secondary LPP reaction using an iron chloride reactant solution. The nitrogen component at 3.77 at. % formed uniformly over the activated carbon (AC) surface after a 1 h LPP reaction. Iron oxide nanoparticles, 40~100 nm in size, were impregnated homogeneously over the NC surface after the LPP reaction, and were identified as Fe₃O₄ by X-ray photoelectron spectroscopy and X-ray diffraction. NC and IONCCs exhibited pseudo-capacitive characteristics, and their specific capacitance and cycling stability were superior to those of bare AC. The nitrogen content on the NC surface increased the compatibility and charge transfer rate, and the composites containing iron oxide exhibited a lower equivalent series resistance.

  20. JAVA Stereo Display Toolkit

    NASA Technical Reports Server (NTRS)

    Edmonds, Karina

    2008-01-01

    This toolkit provides a common interface for displaying graphical user interface (GUI) components in stereo using either specialized stereo display hardware (e.g., liquid crystal shutter or polarized glasses) or anaglyph display (red/blue glasses) on standard workstation displays. An application using this toolkit will work without modification in either environment, allowing stereo software to reach a wider audience without sacrificing high-quality display on dedicated hardware. The toolkit is written in Java for use with the Swing GUI Toolkit and has cross-platform compatibility. It hooks into the graphics system, allowing any standard Swing component to be displayed in stereo. It uses the OpenGL graphics library to control the stereo hardware and to perform the rendering. It also supports anaglyph and special stereo hardware using the same API (application-program interface), and has the ability to simulate color stereo in anaglyph mode by combining the red band of the left image with the green/blue bands of the right image. This is a low-level toolkit that accomplishes simply the display of components (including the JadeDisplay image display component). It does not include higher-level functions such as disparity adjustment, 3D cursor, or overlays all of which can be built using this toolkit.

  1. Screening phage display libraries for organ-specific vascular immunotargeting in vivo

    PubMed Central

    Valadon, Philippe; Garnett, Jeff D.; Testa, Jacqueline E.; Bauerle, Marc; Oh, Phil; Schnitzer, Jan E.

    2006-01-01

    The molecular diversity of the luminal endothelial cell surface arising in vivo from local variations in genetic expression and tissue microenvironment may create opportunities for achieving targeted molecular imaging and therapies. Here, we describe a strategy to identify probes and their cognate antigens for targeting vascular endothelia of specific organs in vivo. We differentially screen phage libraries to select organ-targeting antibodies by using luminal endothelial cell plasma membranes isolated directly from tissue and highly enriched in natively expressed proteins exposed to the bloodstream. To obviate liver uptake of intravenously injected phage, we convert the phage-displayed antibodies into scFv-Fc fusion proteins, which then are able to rapidly target select organ(s) in vivo as visualized directly by γ-scintigraphic whole-body imaging. Mass spectrometry helps identify the antigen targets. This comprehensive strategy provides new promise for harnessing the power of phage display for mapping vascular endothelia natively in tissue and for achieving vascular targeting of specific tissues in vivo. PMID:16384919

  2. Transposition of the maize transposable element Ac in barley (Hordeum vulgare L.).

    PubMed

    Scholz, S; Lörz, H; Lütticke, S

    2001-01-01

    Transposition of the maize autonomous element Ac (Activator) was investigated in barley (Hordeum vulgare L.) with the aim of developing a transposon tagging system for the latter. The Ac element was introduced into meristematic tissue of barley by microprojectile bombardment. Transposon activity was then examined in the resulting transgenic plants. Multiple excision events were detected in leaf tissue of all plant lines. The mobile elements generated empty donor sites with small DNA sequence alterations, similar to those found in maize. Reintegration of Ac at independent genomic loci in somatic tissue was demonstrated by isolation of new element-flanking regions by AIMS-PCR (amplification of insertion-mutagenized sites). In addition, transmission of transposed Ac elements to progeny plants was confirmed. The results indicate that the introduced Ac element is able to transpose in barley. This is a first step towards the establishment of a transposon tagging system in this economically important crop.

  3. On the magnetized disruption of inertially-confined plasma flows

    NASA Astrophysics Data System (ADS)

    Manuel, Mario; Kuranz, Carolyn; Rasmus, Alexander; Klein, Sallee; MacDonald, Michael; Trantham, Matt; Fein, Jeff; Belancourt, Patrick; Young, Rachel; Keiter, Paul; Drake, R. Paul; Pollock, Brad; Park, Jaebum; Hazi, Andrew; Williams, Jackson; Chen, Hui

    2016-10-01

    The creation and disruption of inertially-collimated plasma flows is investigated through experiment, simulation, and analytical modeling. Laser-generated plasma-jets are shown to be disrupted by an applied 5T B-field along the jet axis. An analytical model of the system describes the disruption mechanism through the competing effects of B-field advection and diffusion. These results indicate that for Rem 10-100, the ratio of inertial to magnetic pressures plays an important role in determining whether a jet is formed, but at high enough Rem , axial B-field amplification prevents inertial collimation altogether. This work is funded by the U.S. DOE, through the NNSA-DS and SC-OFES Joint Program in HED Laboratory Plasmas, Grant Number DE-NA0001840 and in collaboration with LLNL under contract DE-AC52-07NA27344. Support for this work was provided by NASA, under contract NAS8-03060, through Einstein Postdoctoral Fellowship Grant Number PF3-140111. Software used in this work was developed in part by the DOE NNSA ASC- and DOE Office of Science ASCR-supported Flash Center.

  4. ACS (Alma Common Software) operating a set of robotic telescopes

    NASA Astrophysics Data System (ADS)

    Westhues, C.; Ramolla, M.; Lemke, R.; Haas, M.; Drass, H.; Chini, R.

    2014-07-01

    We use the ALMA Common Software (ACS) to establish a unified middleware for robotic observations with the 40cm Optical, 80cm Infrared and 1.5m Hexapod telescopes located at OCA (Observatorio Cerro Armazones) and the ESO 1-m located at La Silla. ACS permits to hide from the observer the technical specifications, like mount-type or camera-model. Furthermore ACS provides a uniform interface to the different telescopes, allowing us to run the same planning program for each telescope. Observations are carried out for long-term monitoring campaigns to study the variability of stars and AGN. We present here the specific implementation to the different telescopes.

  5. Measuring Ionization in Highly Compressed, Near-Degenerate Plasmas

    NASA Astrophysics Data System (ADS)

    Doeppner, Tilo; Kraus, D.; Neumayer, P.; Bachmann, B.; Collins, G. W.; Divol, L.; Kritcher, A.; Landen, O. L.; Pak, A.; Weber, C.; Fletcher, L.; Glenzer, S. H.; Falcone, R. W.; Saunders, A.; Chapman, D.; Baggott, R.; Gericke, D. O.; Yi, A.

    2016-10-01

    A precise knowledge of ionization at given temperature and density is required to accurately model compressibility and heat capacity of materials at extreme conditions. We use x-ray Thomson scattering to characterize the plasma conditions in plastic and beryllium capsules near stagnation in implosion experiments at the National Ignition Facility. We expect the capsules to be compressed to more than 20x and electron densities approaching 1025 cm-3, corresponding to a Fermi energy of 170 eV. Zinc Heα x-rays (9 keV) scattering at 120° off the plasma yields high sensitivity to K-shell ionization, while at the same time constraining density and temperature. We will discuss recent results in the context of ionization potential depression at these extreme conditions. This work was performed under the auspices of the US Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  6. Display Tactics

    ERIC Educational Resources Information Center

    Tetlow, Linda

    2009-01-01

    Display took a wide variety of forms ranging from students presenting their initial planning and thought processes, to displays of their finished work, and their suggestions for extending the task should they, or others, have time to return to it in the future. A variety of different media were used from traditional posters in many shapes and…

  7. Narrow bandwidth Laser-Plasma Accelerator driven Thomson photon source development

    NASA Astrophysics Data System (ADS)

    Geddes, C. G. R.; Tsai, H.-E.; Otero, G.; Liu, X.; van Tilborg, J.; Toth, Cs.; Vay, J.-L.; Lehe, R.; Schroeder, C. B.; Esarey, E.; Friedman, A.; Grote, D. P.; Leemans, W. P.

    2017-10-01

    Compact, high-quality photon sources at MeV energies can be provided by Thomson scattering of a laser from the electron beam of a Laser-Plasma Accelerator (LPA). Recent experiments and simulations demonstrate controllable LPAs in the energy range appropriate to MeV sources. Simulations indicate that high flux with narrow energy spread can be achieved via control of the scattering laser pulse shape and laser guiding, and that undesired background bremsstrahlung can be mitigated by plasma based deceleration of the electron beam after photon production. Construction of experiments and laser capabilities to combine these elements will be presented, along with initial operations, towards a compact photon source system. Work supported by US DOE NNSA DNN R&D and by Sc. HEP under contract DE-AC02-05CH11231.

  8. Displays and simulators

    NASA Astrophysics Data System (ADS)

    Mohon, N.

    A 'simulator' is defined as a machine which imitates the behavior of a real system in a very precise manner. The major components of a simulator and their interaction are outlined in brief form, taking into account the major components of an aircraft flight simulator. Particular attention is given to the visual display portion of the simulator, the basic components of the display, their interactions, and their characteristics. Real image displays are considered along with virtual image displays, and image generators. Attention is given to an advanced simulator for pilot training, a holographic pancake window, a scan laser image generator, the construction of an infrared target simulator, and the Apollo Command Module Simulator.

  9. Numerical minimization of AC losses in coaxial coated conductor cables

    NASA Astrophysics Data System (ADS)

    Rostila, L.; Suuriniemi, S.; Lehtonen, J.; Grasso, G.

    2010-02-01

    Power cables are one of the most promising applications for the superconducting coated conductors. In the AC use, only small resistive loss is generated, but the removal of the dissipated heat from the cryostat is inefficient due to the large temperature difference. The aim of this work is to minimize the AC losses in a multilayer coaxial cable, in which the tapes form current carrying cylinders. The optimized parameters are the tape numbers and lay angles in these cylinders. This work shows how to cope with the mechanical constraints for the lay angles and discrete tape number in optimization. Three common types of coaxial cables are studied here to demonstrate the feasibility of optimization, in which the AC losses were computed with a circuit analysis model formulated here for arbitrary phase currents, number of phases, and layers. Because the current sharing is practically determined by the inductances of the layers, the optima were obtained much faster by neglecting the nonlinear resistances caused by the AC losses. In addition, the example calculations show that the optimal cable structure do not usually depend on the AC loss model for the individual tapes. On the other hand, depending on the cable type, the losses of the optimized cables may be sensitive to the lay angles, and therefore, we recommend to study the sensitivity for the new cable designs individually.

  10. Targeting hepatic cancer cells with pegylated dendrimers displaying N-acetylgalactosamine and SP94 peptide ligands.

    PubMed

    Medina, Scott H; Tiruchinapally, Gopinath; Chevliakov, Maxim V; Durmaz, Yasemin Yuksel; Stender, Rachell N; Ensminger, William D; Shewach, Donna S; Elsayed, Mohamed E H

    2013-10-01

    Poly(amidoamine) (PAMAM) dendrimers are branched water-soluble polymers defined by consecutive generation numbers (Gn) indicating a parallel increase in size, molecular weight, and number of surface groups available for conjugation of bioactive agents. In this article, we compare the biodistribution of N-acetylgalactosamine (NAcGal)-targeted [(14) C]1 -G5-(NH2 )5 -(Ac)108 -(NAcGal)14 particles to non-targeted [(14) C]1 -G5-(NH2 )127 and PEGylated [(14) C]1 -G5-(NH2 )44 -(Ac)73 -(PEG)10 particles in a mouse hepatic cancer model. Results show that both NAcGal-targeted and non-targeted particles are rapidly cleared from the systemic circulation with high distribution to the liver. However, NAcGal-targeted particles exhibited 2.5-fold higher accumulation in tumor tissue compared to non-targeted ones. In comparison, PEGylated particles showed a 16-fold increase in plasma residence time and a 5-fold reduction in liver accumulation. These results motivated us to engineer new PEGylated G5 particles with PEG chains anchored to the G5 surface via acid-labile cis-aconityl linkages where the free PEG tips are functionalized with NAcGal or SP94 peptide to investigate their potential as targeting ligands for hepatic cancer cells as a function of sugar conformation (α versus β), ligand concentration (100-4000 nM), and incubation time (2 and 24 hours) compared to fluorescently (Fl)-labeled and non-targeted G5-(Fl)6 -(NH2 )122 and G5-(Fl)6 -(Ac)107 -(cPEG)15 particles. Results show G5-(Fl)6 -(Ac)107 -(cPEG[NAcGalβ ])14 particles achieve faster uptake and higher intracellular concentrations in HepG2 cancer cells compared to other G5 particles while escaping the non-specific adsorption of serum protein and phagocytosis by Kupffer cells, which make these particles the ideal carrier for selective drug delivery into hepatic cancer cells. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Effect of protein properties on display efficiency using the M13 phage display system.

    PubMed

    Imai, S; Mukai, Y; Takeda, T; Abe, Y; Nagano, K; Kamada, H; Nakagawa, S; Tsunoda, S; Tsutsumi, Y

    2008-10-01

    The M13 phage display system is a powerful technology for engineering proteins such as functional mutant proteins and peptides. In this system, it is necessary that the protein is displayed on the phage surface. Therefore, its application is often limited when a protein is poorly displayed. In this study, we attempted to understand the relationship between a protein's properties and its display efficiency using the well-known pIII and pVIII type phage display system. The display of positively charged SV40 NLS and HIV-1 Tat peptides on pill was less efficient than that of the neutrally charged RGDS peptide. When different molecular weight proteins (1.5-58 kDa) were displayed on pIII and pVIII, their display efficiencies were directly influenced by their molecular weights. These results indicate the usefulness in predicting a desired protein's compatibility with protein and peptide engineering using the phage display system.

  12. Travel Support for Scientists to Participate in ACS Symposium

    DTIC Science & Technology

    2017-08-31

    Report: Travel Support for Scientists to Participate in ACS Symposium The views, opinions and/or findings contained in this report are those of the...to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data...Number: W911NF-16-1-0110 Organization: University of Notre Dame Title: Travel Support for Scientists to Participate in ACS Symposium Report Term

  13. Displays enabling mobile multimedia

    NASA Astrophysics Data System (ADS)

    Kimmel, Jyrki

    2007-02-01

    With the rapid advances in telecommunications networks, mobile multimedia delivery to handsets is now a reality. While a truly immersive multimedia experience is still far ahead in the mobile world, significant advances have been made in the constituent audio-visual technologies to make this become possible. One of the critical components in multimedia delivery is the mobile handset display. While such alternatives as headset-style near-to-eye displays, autostereoscopic displays, mini-projectors, and roll-out flexible displays can deliver either a larger virtual screen size than the pocketable dimensions of the mobile device can offer, or an added degree of immersion by adding the illusion of the third dimension in the viewing experience, there are still challenges in the full deployment of such displays in real-life mobile communication terminals. Meanwhile, direct-view display technologies have developed steadily, and can provide a development platform for an even better viewing experience for multimedia in the near future. The paper presents an overview of the mobile display technology space with an emphasis on the advances and potential in developing direct-view displays further to meet the goal of enabling multimedia in the mobile domain.

  14. Introducing AC inductive reactance with a power tool

    NASA Astrophysics Data System (ADS)

    Bryant, Wesley; Baker, Blane

    2016-09-01

    The concept of reactance in AC electrical circuits is often non-intuitive and difficult for students to grasp. In order to address this lack of conceptual understanding, classroom exercises compare the predicted resistance of a power tool, based on electrical specifications, to measured resistance. Once students discover that measured resistance is smaller than expected, they are asked to explain these observations using previously studied principles of magnetic induction. Exercises also introduce the notion of inductive reactance and impedance in AC circuits and, ultimately, determine self-inductance of the motor windings within the power tool.

  15. EMU helmet mounted display

    NASA Technical Reports Server (NTRS)

    Marmolejo, Jose (Inventor); Smith, Stephen (Inventor); Plough, Alan (Inventor); Clarke, Robert (Inventor); Mclean, William (Inventor); Fournier, Joseph (Inventor)

    1990-01-01

    A helmet mounted display device is disclosed for projecting a display on a flat combiner surface located above the line of sight where the display is produced by two independent optical channels with independent LCD image generators. The display has a fully overlapped field of view on the combiner surface and the focus can be adjusted from a near field of four feet to infinity.

  16. AC electrothermal technique in microchannels

    NASA Astrophysics Data System (ADS)

    Salari, Alinaghi; Navi, Maryam; Dalton, Colin

    2017-02-01

    Electrokinetic techniques have a wide range of applications in droplet, particle, and fluid manipulation systems. In general, they can be categorized into different subgroups including electroosmosis, electrothermal, electrophoresis, dielectrophoresis, etc. The AC electrothermal (ACET) technique has been shown to be very effective in applications which involve high conductivity fluids, such as blood, which are typically used in biomedical applications. In the past few years, the ACET effect has received considerable attention. Unlike AC electroosmosis (ACEO), the ACET effect shows plateaus in force in a wide frequency range. In other words, with electrothermal force, velocity is more steady and predictable at different frequencies, compared to ACEO and dielectrophoresis (DEP). Although electrothermal microflows form as a result of Joule heating in the fluid, due to high conduction of heat to the ambience, the temperature rise in the fluid is not so high as to threaten the nature of the biofluids. The average temperature rise resulting from the ACET effect is below 5 °K. In order to generate high strength AC electric fields, microfabricated electrode arrays are commonly used in microchannels. For pumping applications, it is essential to create asymmetry in the electric field, typically by having asymmetrical electrode pairs. There is no defined border between many electrokinetic techniques, and as such the point where electrothermal processes interferes with other electrokinetic techniques is not clear in the literature. In addition, there have been comprehensive reviews on micropumps, electrokinetics, and their subcategories, but the literature lacks a detailed up-to-date review on electrothermal microdevices. In this paper, a brief review is made specifically on electric fields in ACET devices, in order to provide an insight for the reader about the importance of this aspect of ACET devices and the improvements made to date.

  17. Modeling AC ripple currents in HTS coated conductors by integral equations

    NASA Astrophysics Data System (ADS)

    Grilli, Francesco; Xu, Zhihan

    2016-12-01

    In several HTS applications, the superconducting tapes experience the simultaneous presence of DC and AC excitations. For example in high-current DC cables, where the transport current is not perfectly constant, but it exhibits some ripples at different frequencies introduced by the rectification process (AC-DC conversion). These ripples give rise to dissipation, whose magnitude and possible influence on the device's cooling requirements need to be evaluated. Here we report a study of the AC losses in a HTS coated conductor subjected to DC currents and AC ripples simultaneously. The modeling approach is based on an integral equation method for thin superconductors: the superconducting tape is modeled as a 1-D object with a non-linear resistivity, which includes the dependence of the critical current density Jc on the magnetic field. The model, implemented in a commercial finite-element program, runs very fast (the simulation of one AC cycle typically takes a few seconds on standard desktop workstation): this allows simulating a large number of cycles and estimating when the AC ripple losses stabilize to a constant value. The model is used to study the influence of the flux creep power index n on the stabilization speed and on the AC loss values, as well as the effect of using a field-dependent Jc instead of a constant one. The simulations confirm that the dissipation level should not be a practical concern in HTS DC cables. At the same time, however, they reveal a strong dependence of the results upon the power index n and the form of Jc , which spurs the question whether the power-law is the most suitable description of the superconductor's electrical behavior for this kind of analysis.

  18. Cosmic shear analysis of archival HST/ACS data. I. Comparison of early ACS pure parallel data to the HST/GEMS survey

    NASA Astrophysics Data System (ADS)

    Schrabback, T.; Erben, T.; Simon, P.; Miralles, J.-M.; Schneider, P.; Heymans, C.; Eifler, T.; Fosbury, R. A. E.; Freudling, W.; Hetterscheidt, M.; Hildebrandt, H.; Pirzkal, N.

    2007-06-01

    Context: This is the first paper of a series describing our measurement of weak lensing by large-scale structure, also termed “cosmic shear”, using archival observations from the Advanced Camera for Surveys (ACS) on board the Hubble Space Telescope (HST). Aims: In this work we present results from a pilot study testing the capabilities of the ACS for cosmic shear measurements with early parallel observations and presenting a re-analysis of HST/ACS data from the GEMS survey and the GOODS observations of the Chandra Deep Field South (CDFS). Methods: We describe the data reduction and, in particular, a new correction scheme for the time-dependent ACS point-spread-function (PSF) based on observations of stellar fields. This is currently the only technique which takes the full time variation of the PSF between individual ACS exposures into account. We estimate that our PSF correction scheme reduces the systematic contribution to the shear correlation functions due to PSF distortions to <2 × 10-6 for galaxy fields containing at least 10 stars, which corresponds to ⪉5% of the cosmological signal expected on scales of a single ACS field. Results: We perform a number of diagnostic tests indicating that the remaining level of systematics is consistent with zero for the GEMS and GOODS data confirming the success of our PSF correction scheme. For the parallel data we detect a low level of remaining systematics which we interpret to be caused by a lack of sufficient dithering of the data. Combining the shear estimate of the GEMS and GOODS observations using 96 galaxies arcmin-2 with the photometric redshift catalogue of the GOODS-MUSIC sample, we determine a local single field estimate for the mass power spectrum normalisation σ8, CDFS=0.52+0.11-0.15 (stat) ± 0.07(sys) (68% confidence assuming Gaussian cosmic variance) at a fixed matter density Ω_m=0.3 for a ΛCDM cosmology marginalising over the uncertainty of the Hubble parameter and the redshift distribution. We

  19. Comparing the ACS/WFC and WFC3/UVIS Calibration and Photometry

    NASA Astrophysics Data System (ADS)

    Deustua, S. E.; Mack, J.

    2018-03-01

    A study was undertaken using synthetic photometry of CALSPEC stars to compare the ACS Wide Field Channel (WFC) photometry to the WFC3 UVIS imaging channel in eight similarly named passbands corresponding to the broadband filters F435W (ACS/WFC) F438W (WFC3/UVIS) and F475W, F555W, F606W, F625W, F775W, F814W and F850LP (both ACS/WFC and WFC3/UVIS). The uncertainty of the photometric calibration of ACS/WFC and WFC3/UVIS with respect to the white dwarf standard stars is within ± 0.5% for F814W, F775W, F606W and F475W, and within ±1% for F625W and F850LP. For F555W the apparent difference in the calibration is 2% for F555W and 6% for UVIS/F438W and ACS/F435W due to inherent differences in the filter passbands. Comparing the ACS/WFC to WFC3/UVIS mean flux for stars having a range of spectral types shows a color dependence. The WFC to UVIS F814W color dependence is ± 0.02 mags for F814W, F775W, F475W and F606W. For the other filters the range is -0.06 to +0.02 mags. Aperture photometry of the 47 Tucanae cluster confirm the results from using synthetic photometry of CALSPEC stars.

  20. Established and potential physiological roles of bicarbonate-sensing soluble adenylyl cyclase (sAC) in aquatic animals

    PubMed Central

    Tresguerres, Martin; Barott, Katie L.; Barron, Megan E.; Roa, Jinae N.

    2014-01-01

    Soluble adenylyl cyclase (sAC) is a recently recognized source of the signaling molecule cyclic AMP (cAMP) that is genetically and biochemically distinct from the classic G-protein-regulated transmembrane adenylyl cyclases (tmACs). Mammalian sAC is distributed throughout the cytoplasm and it may be present in the nucleus and inside mitochondria. sAC activity is directly stimulated by HCO3−, and sAC has been confirmed to be a HCO3− sensor in a variety of mammalian cell types. In addition, sAC can functionally associate with carbonic anhydrases to act as a de facto sensor of pH and CO2. The two catalytic domains of sAC are related to HCO3−-regulated adenylyl cyclases from cyanobacteria, suggesting the cAMP pathway is an evolutionarily conserved mechanism for sensing CO2 levels and/or acid/base conditions. Reports of sAC in aquatic animals are still limited but are rapidly accumulating. In shark gills, sAC senses blood alkalosis and triggers compensatory H+ absorption. In the intestine of bony fishes, sAC modulates NaCl and water absorption. And in sea urchin sperm, sAC may participate in the initiation of flagellar movement and in the acrosome reaction. Bioinformatics and RT-PCR results reveal that sAC orthologs are present in most animal phyla. This review summarizes the current knowledge on the physiological roles of sAC in aquatic animals and suggests additional functions in which sAC may be involved. PMID:24574382

  1. Characterization of particulate matter binding peptides screened from phage display.

    PubMed

    Liang Alvin, Aw Wei; Tanaka, Masayoshi; Okochi, Mina

    2017-05-01

    Particulate matter (PM), especially particulates with diameters of less than 2.5 μm, can penetrate the alveolar region and increase the risk of respiratory diseases. This has stimulated research efforts to develop detection methods so that counter measures can be taken. In this study, four PM binding peptides were obtained by phage display and binding characteristics of these peptides were investigated using the peptide array. The strongest binding peptide, WQDFGAVRSTRS, displayed a binding property, measured in terms of spot intensity, 11.4 times higher than that of the negative control, AAAAA. Inductively coupled plasma mass spectrometry (ICPMS) analysis of the transition metal compounds in the PM bound to the peptide spots was performed, and two peptides showed higher binding towards Cu and Zn compounds in PM. These results suggest that the screened peptides could serve as an indicator of transition metal compounds, which are related to adverse health effects, contained in PM. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  2. Superconducting ac cable

    NASA Astrophysics Data System (ADS)

    Schmidt, F.

    1980-11-01

    The components of a superconducting 110 kV ac cable for power ratings or = 2000 MVA were developed. The cable design is of the semiflexible type, with a rigid cryogenic envelope containing a flexible hollow coaxial cable core. The cable core consists of spirally wound Nb-A1 composite wires electrically insulated by high pressure polyethylene tape wrappings. A 35 m long single phase test cable with full load terminals rated at 110 kV and 10 kA was constructed and successfully tested. The results obtained prove the technical feasibility and capability of this cable design.

  3. Diode-rectified multiphase AC arc for the improvement of electrode erosion characteristics

    NASA Astrophysics Data System (ADS)

    Tanaka, Manabu; Hashizume, Taro; Saga, Koki; Matsuura, Tsugio; Watanabe, Takayuki

    2017-11-01

    An innovative multiphase AC arc (MPA) system was developed on the basis of a diode-rectification technique to improve electrode erosion characteristics. Conventionally, electrode erosion in AC arc is severer than that in DC arc. This originated from the fact that the required properties for the cathode and anode are different, although an AC electrode works as the cathode and the anode periodically. To solve this problem, a separation of AC electrodes into pairs of thoriated tungsten cathode and copper anode by diode-rectification was attempted. A diode-rectified multiphase AC arc (DRMPA) system was then successfully established, resulting in a drastic improvement of the erosion characteristics. The electrode erosion rate in the DRMPA was less than one-third of that in the conventional MPA without the diode rectification. In order to clarify its erosion mechanism, electrode phenomena during discharge were visualized by a high-speed camera system with appropriate band-pass filters. Fluctuation characteristics of the electrode temperature in the DRMPA were revealed.

  4. Observational data needs for plasma phenomena

    NASA Technical Reports Server (NTRS)

    Niedner, M. B., Jr.

    1981-01-01

    Bright comets display a rich variety of interesting plasma phenomena which occur over an enormous range of spatial scales, and which require different observational techniques to be studied effectively. Wide-angle photography of high time resolution is probably the best method of studying the phenomenon of largest known scale: the plasma tail disconnection event (DE), which has been attributed to magnetic reconnection at interplanetary sector boundary crossings. These structures usually accelerate as they recede from the head region and observed velocities are typically in the range 50 V km/s. They are often visible for several days following the time of disconnection, and are sometimes seen out past 0.2 AU from the cometary head. The following areas pertaining to plasma phenomena in the ionoshere are addressed: the existence, size, and heliocentric distance variations of the contact surface, and the observational signatures of magnetic reconnection at sector boundary crossings.

  5. Faradaic AC Electrokinetic Flow and Particle Traps

    NASA Astrophysics Data System (ADS)

    Ben, Yuxing; Chang, Hsueh-Chia

    2004-11-01

    Faradaic reaction at higher voltages can produce co-ion polarization at AC electrodes instead of counter-ion polarization due to capacitive charging from the bulk. The Faradaic co-ion polarization also does not screen the external field and hence can produce large net electro-kinetic flows at frequencies lower than the inverse RC time of the double layer. Due to the opposite polarization of capacitve and Faradaic charging, we can reverse the direction of AC flows on electrodes by changing the voltage and frequency. Particles and bacteria are trapped and then dispersed at stagnation lines, at locations predicted by our theory, by using these two flows sequentially. This technique offers a good way to concentrate and detect bacteria.

  6. AC application of second generation HTS wire

    NASA Astrophysics Data System (ADS)

    Thieme, C. L. H.; Gagnon, K.; Voccio, J.; Aized, D.; Claassen, J.

    2008-02-01

    For the production of Second Generation (2G) YBCO High Temperature Superconductor wire American Superconductor uses a wide-strip MOD-YBCO/RABiTSTM process, a low-cost approach for commercial manufacturing. It can be engineered with a high degree of flexibility to manufacture practical 2G conductors with architectures and properties tailored for specific applications and operating conditions. For ac applications conductor and coil design can be geared towards low hysteretic losses. For applications which experience high frequency ac fields, the stabilizer needs to be adjusted for low eddy current losses. For these applications a stainless-steel laminate is used. An example is a Low Pass Filter Inductor which was developed and built in this work.

  7. Advanced Plasma Shape Control to Enable High-Performance Divertor Operation on NSTX-U

    NASA Astrophysics Data System (ADS)

    Vail, Patrick; Kolemen, Egemen; Boyer, Mark; Welander, Anders

    2017-10-01

    This work presents the development of an advanced framework for control of the global plasma shape and its application to a variety of shape control challenges on NSTX-U. Operations in high-performance plasma scenarios will require highly-accurate and robust control of the plasma poloidal shape to accomplish such tasks as obtaining the strong-shaping required for the avoidance of MHD instabilities and mitigating heat flux through regulation of the divertor magnetic geometry. The new control system employs a high-fidelity model of the toroidal current dynamics in NSTX-U poloidal field coils and conducting structures as well as a first-principles driven calculation of the axisymmetric plasma response. The model-based nature of the control system enables real-time optimization of controller parameters in response to time-varying plasma conditions and control objectives. The new control scheme is shown to enable stable and on-demand plasma operations in complicated magnetic geometries such as the snowflake divertor. A recently-developed code that simulates the nonlinear evolution of the plasma equilibrium is used to demonstrate the capabilities of the designed shape controllers. Plans for future real-time implementations on NSTX-U and elsewhere are also presented. Supported by the US DOE under DE-AC02-09CH11466.

  8. Plasma theory and simulation

    NASA Astrophysics Data System (ADS)

    Birdsall, Charles K.

    1986-12-01

    The Pierce diode linear behavior with external R, C, or L was verified very accurately by particle simulation. The Pierce diode non-linear equilibria with R, C, or L are described theoretically and explored via computer simulation. A simple model of the sheath outside the separatrix of an FRC was modeled electrostatically in 2d and large potentials due to the magnetic well and peak which were found. These may explain the anomalously high ion confinement in the FRC edge layer. A planar plasma source with cold ions and warm electrons produces a source sheath with sufficient potential drop to accelerate ions to sound velocity, which obviates the need for a Bohm pre-collector-sheath electric field. Final reports were prepared for collector sheath, presheath, and source sheath in a collisionless, finite ion temperature plasma; potential drop and transport in a bounded plasma with ion reflection at the collector; potential drop and transport in a bounded plasma with secondary electron emission at the collector. A movie has been made displaying the long-lived vortices resulting from the Kelvin-Helmholtz instability in a magnetized sheath. A relativistic Monte Carlo binary (Coulomb) collision model has been developed and tested for inclusion into the electrostatic particle simulation code TESS. Two direct implicit time integration schemes are tested for self-heating and self-cooling and regions of neither are found as a function of delta t and delta x for the model of a freely expanding plasma slab.

  9. A photophoretic-trap volumetric display

    NASA Astrophysics Data System (ADS)

    Smalley, D. E.; Nygaard, E.; Squire, K.; van Wagoner, J.; Rasmussen, J.; Gneiting, S.; Qaderi, K.; Goodsell, J.; Rogers, W.; Lindsey, M.; Costner, K.; Monk, A.; Pearson, M.; Haymore, B.; Peatross, J.

    2018-01-01

    Free-space volumetric displays, or displays that create luminous image points in space, are the technology that most closely resembles the three-dimensional displays of popular fiction. Such displays are capable of producing images in ‘thin air’ that are visible from almost any direction and are not subject to clipping. Clipping restricts the utility of all three-dimensional displays that modulate light at a two-dimensional surface with an edge boundary; these include holographic displays, nanophotonic arrays, plasmonic displays, lenticular or lenslet displays and all technologies in which the light scattering surface and the image point are physically separate. Here we present a free-space volumetric display based on photophoretic optical trapping that produces full-colour graphics in free space with ten-micrometre image points using persistence of vision. This display works by first isolating a cellulose particle in a photophoretic trap created by spherical and astigmatic aberrations. The trap and particle are then scanned through a display volume while being illuminated with red, green and blue light. The result is a three-dimensional image in free space with a large colour gamut, fine detail and low apparent speckle. This platform, named the Optical Trap Display, is capable of producing image geometries that are currently unobtainable with holographic and light-field technologies, such as long-throw projections, tall sandtables and ‘wrap-around’ displays.

  10. Map display design

    NASA Technical Reports Server (NTRS)

    Aretz, Anthony J.

    1990-01-01

    This paper presents a cognitive model of a pilot's navigation task and describes an experiment comparing a visual momentum map display to the traditional track-up and north-up approaches. The data show the advantage to a track-up map is its congruence with the ego-centered forward view; however, the development of survey knowledge is hindered by the inconsistency of the rotating display. The stable alignment of a north-up map aids the acquisition of survey knowledge, but there is a cost associated with the mental rotation of the display to a track-up alignment for ego-centered tasks. The results also show that visual momentum can be used to reduce the mental rotation costs of a north-up display.

  11. Methylenetetrahydrofolate reductase (MTHFR) gene 677C>T and 1298A>C polymorphisms are associated with differential apoptosis of leukemic B cells in vitro and disease progression in chronic lymphocytic leukemia.

    PubMed

    Nückel, H; Frey, U H; Dürig, J; Dührsen, U; Siffert, W

    2004-11-01

    Methylenetetrahydrofolate reductase (MTHFR) regulates the metabolism of folate and methionine, essential components of DNA synthesis and methylation. We investigated whether the two genetic MTHFR polymorphisms (677C>T and 1298A>C) are associated with an increased risk for chronic lymphocytic leukemia (CLL) or may predict disease progression. Moreover, we measured potential genotype effects on apoptosis of B-CLL cells.Allele frequencies and genotype distributions for both polymorphisms were not significantly different in 111 patients vs 92 healthy controls. While progression-free survival (PFS) was not significantly different in individuals with CLL including all stages, in patients with Binet stage A PFS was significantly longer in patients displaying the MTHFR 677CC (P=0.043) and the MTHFR 1298A/C or CC genotypes (P=0.019). In a multivariate analysis, MTHFR haplotype (677CC plus 1298CC or A/C) was the best independent prognostic factor for PFS compared with other known prognostic factors. Spontaneous apoptosis of B-CLL cells in vitro was significantly increased in the favorable risk group with MTHFR 677CC and MTHFR 1298AC, which may constitute the cellular basis of the observed associations. While MTHFR polymorphisms do not affect the risk for B-CLL, they may be independent prognostic markers that influence the PFS in patients with early-stage B-CLL.

  12. AC Application of HTS Conductors in Highly Dynamic Electric Motors

    NASA Astrophysics Data System (ADS)

    Oswald, B.; Best, K.-J.; Setzer, M.; Duffner, E.; Soell, M.; Gawalek, W.; Kovalev, L. K.

    2006-06-01

    Based on recent investigations we design highly dynamic electric motors up to 400 kW and linear motors up to 120 kN linear force using HTS bulk material and HTS tapes. The introduction of HTS tapes into AC applications in electric motors needs fundamental studies on double pancake coils under transversal magnetic fields. First theoretical and experimental results on AC field distributions in double-pancake-coils and corresponding AC losses will be presented. Based on these results the simulation of the motor performance confirms extremely high power density and efficiency of both types of electric motors. Improved characteristics of rare earth permanent magnets used in our motors at low temperatures give an additional technological benefit.

  13. Children's Control/Display Stereotypes.

    PubMed

    Hoffmann, Errol R; Chan, Alan H S; Tai, Judy P C

    2018-06-01

    Objective The aim of this study was to determine control/display stereotypes for children of a range of ages and development of these stereotypes with age. Background Little is known about control/display stereotypes for children of different ages and the way in which these stereotypes develop with age. This study is part of a program to determine the need to design differentially for these age groups. Method We tested four groups of children with various tasks (age groups 5 to 7, 8 to 10, 11 to 13, 14 to 16), with about 30 in each group. Examples of common tasks were opening a bottle, turning on taps, and allocating numbers to keypads. More complex tasks involved rotating a control to move a display in a requested direction. Results Tasks with which different age groups were familiar showed no effect of age group. Different control/display arrangements generally showed an increase in stereotype strength with age, with dependence on the form of the control/display arrangement. Two-dimensional arrangements, with the control on the same plane as the display, had higher stereotype strength than three-dimensional arrangements for all age groups, suggesting an effect of familiarity with controls and displays with increasing age. Conclusion Children's control/display stereotypes do not differ greatly from those of adults, and hence, design for children older than 5 years of age, for control/display stereotypes, can be the same as that for adult populations. Application When designing devices for children, the relationship between controls and displays can be as for adult populations, for which there are considerable experimental data.

  14. AC-Induced Bias Potential Effect on Corrosion of Steels

    DTIC Science & Technology

    2009-02-05

    induction, variable conduction Experimental Setup Super- martensitic stainless steel composition Analysis: C Mn Si Cr Ni Mo Cu N Typical 13 Cr ɘ.01 0.6... stainless steel used in pipelines. •Low carbon (ɘ.01): allows the formation of a “soft” martensite that is more resistant than standard martensitic ...Proposed AC Corrosion Models  AC Simulated Corrosion testing  Stainless steel pipe and coating  Cathodic protection  Experimental Setup  Preliminary

  15. Panoramic projection avionics displays

    NASA Astrophysics Data System (ADS)

    Kalmanash, Michael H.

    2003-09-01

    Avionics projection displays are entering production in advanced tactical aircraft. Early adopters of this technology in the avionics community used projection displays to replace or upgrade earlier units incorporating direct-view CRT or AMLCD devices. Typical motivation for these upgrades were the alleviation of performance, cost and display device availability concerns. In these systems, the upgraded (projection) displays were one-for-one form / fit replacements for the earlier units. As projection technology has matured, this situation has begun to evolve. The Lockheed-Martin F-35 is the first program in which the cockpit has been specifically designed to take advantage of one of the more unique capabilities of rear projection display technology, namely the ability to replace multiple small screens with a single large conformal viewing surface in the form of a panoramic display. Other programs are expected to follow, since the panoramic formats enable increased mission effectiveness, reduced cost and greater information transfer to the pilot. Some of the advantages and technical challenges associated with panoramic projection displays for avionics applications are described below.

  16. Why Nuclear Forensics Needs New Plasma Chemistry Data

    NASA Astrophysics Data System (ADS)

    Rose, T.; Armstrong, M.; Chernov, A.; Crowhurst, J.; Dai, Z.; Knight, K.; Koroglu, B.; Radousky, H.; Stavrou, E.; Weisz, D.; Zaug, J.; Azer, M.; Finko, M.; Curreli, D.

    2016-10-01

    The mechanisms that control the distribution of radionuclides in fallout after a nuclear detonation are not adequately constrained. Current capabilities for assessing post-detonation scenarios often rely on empirical observations and approximations. Deeper insight into chemical condensation requires a coupled experimental, theoretical, and modeling approach. The behavior of uranium during plasma condensation is perplexing. Two independent methods are being developed to investigate gas phase uranium chemistry and speciation during plasma condensation: (1) laser-induced breakdown spectroscopy and (2) a unique steady-state ICP flow reactor. Both methods use laser absorption spectroscopy to obtain in situ data for vapor phase molecular species as they form. We are developing a kinetic model to describe the relative abundance of uranium species in the evolving plasma. Characterization of the uranium-oxygen system will be followed by other chemical components, including `carrier' materials such as silica. The goal is to develop a semi-empirical model to describe the chemical fractionation of uranium during fallout formation. Prepared by LLNL under Contract DE-AC52-07NA27344. This project was sponsored in part by the Department of the Defense, Defense Threat Reduction Agency, under Grant Number HDTRA1-16-1-0020.

  17. AC losses in horizontally parallel HTS tapes for possible wireless power transfer applications

    NASA Astrophysics Data System (ADS)

    Shen, Boyang; Geng, Jianzhao; Zhang, Xiuchang; Fu, Lin; Li, Chao; Zhang, Heng; Dong, Qihuan; Ma, Jun; Gawith, James; Coombs, T. A.

    2017-12-01

    This paper presents the concept of using horizontally parallel HTS tapes with AC loss study, and the investigation on possible wireless power transfer (WPT) applications. An example of three parallel HTS tapes was proposed, whose AC loss study was carried out both from experiment using electrical method; and simulation using 2D H-formulation on the FEM platform of COMSOL Multiphysics. The electromagnetic induction around the three parallel tapes was monitored using COMSOL simulation. The electromagnetic induction and AC losses generated by a conventional three turn coil was simulated as well, and then compared to the case of three parallel tapes with the same AC transport current. The analysis demonstrates that HTS parallel tapes could be potentially used into wireless power transfer systems, which could have lower total AC losses than conventional HTS coils.

  18. Ganoboninketals A-C, Antiplasmodial 3,4-seco-27-Norlanostane Triterpenes from Ganoderma boninense Pat.

    PubMed

    Ma, Ke; Ren, Jinwei; Han, Junjie; Bao, Li; Li, Li; Yao, Yijian; Sun, Chen; Zhou, Bing; Liu, Hongwei

    2014-08-22

    Three new nortriterpenes, ganoboninketals A-C (1-3), featuring rearranged 3,4-seco-27-norlanostane skeletons and highly complex polycyclic systems were isolated from the medicinal mushroom Ganoderma boninense. The structures of the new metabolites were established by spectroscopic methods. The absolute configurations in 1-3 were assigned by electronic circular dichroism (ECD) calculations. Compounds 1-3 showed antiplasmodial activity against Plasmodium falciparum with IC50 values of 4.0, 7.9, and 1.7 μM, respectively. Compounds 1 and 3 also displayed weak cytotoxicity against A549 cell line with IC50 values of 47.6 and 35.8 μM, respectively. Compound 2 showed weak cytotoxicity toward HeLa cell line with an IC50 value of 65.5 μM. Compounds 1-3 also presented NO inhibitory activity in the LPS-induced macrophages with IC50 values of 98.3, 24.3, and 60.9 μM, respectively.

  19. Characterization of Low Pressure Cold Plasma in the Cleaning of Contaminated Surfaces

    NASA Technical Reports Server (NTRS)

    Lanz, Devin Garrett; Hintze, Paul E.

    2016-01-01

    The characterization of low pressure cold plasma is a broad topic which would benefit many different applications involving such plasma. The characterization described in this paper focuses on cold plasma used as a medium in cleaning and disinfection applications. Optical Emission Spectroscopy (OES) and Mass Spectrometry (MS) are the two analytical methods used in this paper to characterize the plasma. OES analyzes molecules in the plasma phase by displaying the light emitted by the plasma molecules on a graph of wavelength vs. intensity. OES was most useful in identifying species which may interact with other molecules in the plasma, such as atomic oxygen or hydroxide radicals. Extracting useful data from the MS is done by filtering out the peaks generated by expected molecules and looking for peaks caused by foreign ones leaving the plasma chamber. This paper describes the efforts at setting up and testing these methods in order to accurately and effectively characterize the plasma.

  20. AC Conductivity and Dielectric Properties of Borotellurite Glass

    NASA Astrophysics Data System (ADS)

    Taha, T. A.; Azab, A. A.

    2016-10-01

    Borotellurite glasses with formula 60B2O3-10ZnO-(30 - x)NaF- xTeO2 ( x = 0 mol.%, 5 mol.%, 10 mol.%, and 15 mol.%) have been synthesized by thermal melting. X-ray diffraction (XRD) analysis confirmed that the glasses were amorphous. The glass density ( ρ) was determined by the Archimedes method at room temperature. The density ( ρ) and molar volume ( V m) were found to increase with increasing TeO2 content. The direct-current (DC) conductivity was measured in the temperature range from 473 K to 623 K, in which the electrical activation energy of ionic conduction increased from 0.27 eV to 0.48 eV with increasing TeO2 content from 0 mol.% to 15 mol.%. The dielectric parameters and alternating-current (AC) conductivity ( σ ac) were investigated in the frequency range from 1 kHz to 1 MHz and temperature range from 300 K to 633 K. The AC conductivity and dielectric constant decreased with increasing TeO2 content from 0 mol.% to 15 mol.%.