Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer ce...
National Technical Information Service (NTIS)
The Idaho National Engineering Laboratory (INEL) has been investigating the feasibility of a concept for an accelerator-based source of epithermal neutrons for BNCT that is based on the use of a two-stage photoneutron production process driven by an elect...
The authors plan to build a BNCT facility based on electrostatic quadrupole (ESQ) accelerator technology. It is an experimentally-proven technology capable of delivering a high proton current for producing a neutron intensity greater than what is required for BNCT clinical trials. They also present a design of a ...
DOE Information Bridge
This work reports on the characterisation of a neutron beam shaping assembly (BSA) prototype and on the preliminary modelling of a treatment room for BNCT within the framework of a research programme for the development and construction of an accelerator-based BNCT irradiation facility in Buenos Aires, Argentina. The BSA prototype ...
PubMed
The overall goal of this project was to develop an accelerator-based neutron source (ABNS) for Boron Neutron Capture Therapy (BNCT). Specifically, our goals were to design, and confirm by measurement, a target assembly and a moderator assembly that would fulfill the design requirements of the ABNS. These design requirements were 1) that the neutron field ...
Within the frame of an ongoing project to develop a folded Tandem-Electrostatic-Quadrupole accelerator facility for Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT) a theoretical study was performed to assess the treatment planning capability of different configurations of an optimized beam shaping assembly for such a ...
An accelerator-based BNCT facility is under construction at the Berkeley Lab. An electrostatic-quadrupole (ESQ) accelerator is under development for the production of neutrons via the (sup 7)Li(p,n)(sup 7)Be reaction at proton energies between 2.3 and 2.5...
Recent interest in the production of epithermal neutrons for use in boron neutron capture therapy (BNCT) has prompted an investigation into the feasibility of generating such neutrons with a tandem cascade accelerator. Accelerator-produced neutrons in the...
A modeling investigation was performed to choose moderator material and size for creating optimal epithermal neutron beams for BNCT based on a proton accelerator and the 7Li(p,n)7Be reaction as a neutrons source. An optimal configuration is suggested for ...
The PNS project is devoted to the design and simulation of a Photo-Neutron Source for BNCT using a Varian 2300C/D electron accelerator. This paper describes the production of the high-energy gamma-rays followed by neutron production in (gamma,n) reaction. To optimize the whole setup and maximize the neutron flux, the FLUKA code is employed to simulate the ...
In this work we present an optimized neutron beam shaping assembly for epithermal Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT) and discuss the simulations leading to its design.
Energy Citations Database
NASA Astrophysics Data System (ADS)
Within the frame of an ongoing project to develop a folded Tandem-Electrostatic-Quadrupole (TESQ) accelerator facility for Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT), we discuss here the electrostatic design of the machine, including the accelerator tubes with electrostatic quadrupoles and the ...
Glioblastoma multiforme and metastatic melanoma are frequent brain tumors in adults and presently still incurable diseases. Boron Neutron Capture Therapy (BNCT) is a promising alternative for this kind of pathologies. Accelerators have been proposed for BNCT as a way to circumvent the problem of siting reactors in hospitals and for ...
Boron Neutron Capture Therapy, a promising modality for the treatment of malignant tumors, relies on the use of neutron beams of suitable energy and intensity. For deep-seated tumors, simulations indicate that the optimal neutron energy is in the epithermal region, and in particular between 1 and 10 keV. Therapeutic neutron beams of high spectral purity could be produced with low-energy ...
We describe Monte Carlo simulations of three facilities for the production of epithermal neutrons for Boron Neutron Capture Therapy (BNCT) and examine general aspects and problems of designing the spectrum-shaping assemblies to be used with these neutron sources. The first facility is based on an accelerator-driven low-power ...
E-print Network
During the last few years, IBA started the development of an accelerator-based BNCT system. The accelerator is a Dynamitron built by RDI in USA and will produce a 20 mA proton beam at 2.8 MeV. Neutrons will be produced by the (7)Li(p,n)(7)Be nuclear reaction using a thin lithium target. The neutron energy spectrum will be tailored ...
A folded tandem, with 1.25 MV terminal voltage, combined with an ElectroStatic Quadrupole (ESQ) chain is being proposed as a machine for Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT). The machine is shown to be capable of accelerating a 30 mA proton beam to 2.5 MeV. These are the specifications needed to produce ...
The reaction {sup 7}Li(p,n){sup 7}Be has been proposed as an accelerator-based source of neutrons for Boron Neutron Capture Therapy (BNCT). This reaction has a large steep resonance for proton energies around 2.3 MeV which ends at approximately 2.5 MeV. It is generally accepted that the use of 2.5 MeV protons produces the highest yield of neutrons for ...
The reaction (sup 7)Li(p,n)(sup 7) Be has been proposed as an accelerator-based source of neutrons for Boron Neutron Capture Therapy (BNCT). This reaction has a large steep resonance for proton energies of about 2.3 MeV which ends at about 2.5 MeV. It has...
A project to develop a Tandem-electrostatic-quadrupole (TESQ) accelerator for accelerator-based boron neutron capture therapy (AB-BNCT) is described. A folded Tandem, with 1.25 MV terminal voltage, combined with an electrostatic quadrupole (ESQ) chain is being proposed. The project goal is a machine capable of delivering 30 mA of 2.5 ...
The SPES-BNCT ongoing project of the Istituto Nazionale di Fisica Nucleare (INFN) is aimed at the construction at the Laboratori Nazionali di Legnaro (LNL) of an accelerator-based (AB), high-flux thermal neutron beam facility devoted to boron neutron capture therapy (BNCT) experimental treatment of extended skin melanoma, in the ...
Since 1986, the Idaho National Engineering Laboratory (INEL) has been involved in the development of epithermal neutron sources for BNCT. The INEL effort was instrumental in the implementation of an epithermal neutron beam at the Brookhaven Medical Research Reactor at Brookhaven National Laboratory. Recently, the INEL's effort has been directed toward developing advanced ...
In boron neutron capture therapy (BNCT) the delivered dose to the patient depends both on the neutron beam characteristics and on the {sup 10}B body distribution which, in turn, is governed by the tumor specificity of the {sup 10}B drug-carrier. BNCT dosimetry is a complex matter due to the several interactions that neutrons can undergo with the different ...
In boron neutron capture therapy (BNCT) the delivered dose to the patient depends both on the neutron beam characteristics and on the 10B body distribution which, in turn, is governed by the tumor specificity of the 10B drug-carrier. BNCT dosimetry is a complex matter due to the several interactions that neutrons can undergo with the different nuclei ...
Boron Neutron Capture Therapy (BNCT) is being studied as a possible radiotherapic treatment for some cancer types. Neutron energy for penetrating into tissue should be in the epithermal range. Different methods are used for neutron production. Electron accelerators are an alternative way for producing neutrons in electron-photon-neutron processes. ...
Accelerator-based neutron sources are an attractive alternative to nuclear reactors for providing epithermal neutron beams for Boron Neutron Capture Therapy. Based on clinical requirements and neutronics modeling the use of proton and deuteron induced reactions in {sup 7}Li and {sup 9}Be targets has been compared. Excellent epithermal neutron beams can be ...
synchrotrons, compact proton linacs for PET isotope production, epithermal neutron sources for the BNCT (PET and SPECT), the production of epithermal neutron beams for BNCT, and accelerated proton beams for the PET application, and neutron production for the BNCT application. These systems, with minor
For several years, research has been ongoing in the Ohio State University (OSU) Nuclear Engineering Program toward the development of an accelerator-based irradiation facility (ANIF) neutron source for boron neutron capture therapy (BNCT). The ANIF, which is planned to be built in a hospital, has been conceptually designed and analyzed. After Qu, an OSU ...
A numerical optimization of a Beam Shaping Assembly (BSA) for Accelerator Based-Boron Neutron Capture Therapy (AB-BNCT) has been performed. The reaction (7)Li(p,n)(7)Be has been considered using a proton beam on a lithium fluoride target. Proton energy and the dimensions of a simple BSA geometry have been varied to obtain a set of ...
Monte Carlo modelling of an irradiation facility, for boron neutron capture therapy (BNCT) application, using a set of advanced type, accelerator based, 3H(d,n)4He (D-T) fusion neutron source device is presented. Some general issues concerning the design of a proper irradiation beam shaping assembly, based on very ...
In the framework of an advanced Exotic Ion Beam facility, named SPES (Study and Production of Exotic Species), that will allow a frontier program both in nuclear and interdisciplinary physics, an intense thermal neutron beam facility, devoted to perform Boron Neutron Capture Therapy (BNCT) experimental treatments on skin melanoma tumor, is currently under construction ...
In the framework of an advanced Exotic Ion Beam facility project, named SPES (Study and Production of Exotic Species), that will allow a frontier program in Nuclear and Interdisciplinary Physics, an intense thermal neutron beam facility, devoted to perform Boron Neutron Capture Therapy (BNCT) experimental treatments on skin melanoma tumor is currently under construction ...
In this work, the performance of an accelerator-based neutron source design has been compared with that of a modern fluoride-filtered reactor-based epithermal beam having near-optimal quality for treatment of deep seated tumors in relation to its applicability for BNCT. The accelerator is a ...
Current accelerator-based neutron source concepts for boron neutron capture therapy (BNCT) are centered on the lithium (p,n) reaction. The near lithium threshold source concept uses proton energies <~100 keV above the reaction threshold energy (1.88 MeV). For deeply seated brain tumors, epithermal (1 eV to 10 keV) neutrons are needed to penetrate the ...
A modeling investigation was performed to choose moderator material and size for creating optimal epithermal neutron beams for BNCT based on a proton accelerator and the 7Li(p,n)7Be reaction as a neutrons source. An optimal configuration is suggested for the beam shaping assembly made from polytetrafluoroethylene and magnesium ...
A 4.1 MeV tandem electrostatic accelerator designed for research into Boron Neutron Capture Therapy (BNCT) has recently been installed in the MIT Laboratory for Accelerator Beam Applications (LABA). This accelerator uses a very high current switch mode high voltage power supply in conjunction with a multi-cusp ...
This is the progress report for the project entitled, ''An Accelerator Neutron Source for BNCT.'' The progress report is for the period from July 1, 1993 to date. The overall objective of our research project is to develop an Accelerator Epithermal Neutro...
Thick lithium targets are excellent sources of neutrons for accelerator boron neutron capture therapy (BNCT), but the low melting point of lithium (181 deg. C) and a need for high proton currents make target heating a concern. However, because neutrons are not produced for proton energies below the {sup 7}Li(p,n){sup 7}Be reaction threshold of 1.88 MeV, ...
An accelerator-driven thermal neutron source for BNCT, planned to be installed at the INFN Laboratori Nazionali di Legnaro (LNL), is in progress in the framework of the SPES (selective production of exotic species) research program. The most critical element of such a facility is the construction of a reliable neutron converter based ...
The CWDD (Continuous Wave Deuterium Demonstrator) accelerator was designed to accelerate 80 mA cw of D{sup {minus}} to 7.5 MeV. Most of the hardware for the first 2 MeV was installed at Argonne and major subsystems had been commissioned when program funding from the Ballistic Missile Defense Organization ended in October 1993. Renamed the Argonne ...
The reaction {sup 7}Li(p,n){sup 7} Be has been proposed as an accelerator-based source of neutrons for Boron Neutron Capture Therapy (BNCT). This reaction has a large steep resonance for proton energies of about 2.3 MeV which ends at about 2.5 MeV. It has generally been accepted that one should use 2.5 MeV protons to get the highest yield of neutrons for ...
Previously, the authors developed the in-phantom neutron field assessment parameters T and D{sub tumor} for the evaluation of epithermal neutron fields for use in boron neutron capture therapy (BNCT). These parameters are based on an energy-spectrum-dependent neutron normal-tissue relative biological effectiveness (RBE) and the treatment planning ...
Previously, the authors have developed the in-phantom neutron field assessment parameters T and D (Tumor) for the evaluation of epithermal neutron fields for use in BNCT. These parameters are based on an energy-spectrum-dependent neutron normal-tissue RBE and the treatment planning methodology of Gahbauer and his co-workers, which includes the effects of ...
The purpose of this study was to estimate the financial costs to start BNCT as a clinical treatment in a hospital. To evaluate more accurate data on the precise costs of BNCT, we analyzed the costs of conventional radiotherapy, carbon ion and proton therapy and compare them to BNCT. An aggregate cost calculation of ...
There has been increasing interest in combining Boron Neutron Capture Therapy (BNCT) with standard radiotherapy, either concomitantly or as a BNCT treatment of a recurrent tumor that was previously irradiated with a medical electron linear accelerator (LINAC). In this work we report the simulated dosimetry of treatments combining ...
A modeling investigation was performed to choose moderator material and size for creating optimal epithermal neutron beams for BNCT based on a proton accelerator and the (7)Li(p,n)(7)Be reaction as a neutrons source. An optimal configuration is suggested for the beam shaping assembly made from polytetrafluoroethylene and magnesium ...
This report is a summary of the progress and research produced for the Idaho National Engineering Laboratory (INEL) Boron Neutron Capture Therapy (BNCT) Research Program for calendar year 1994. Contributions from the principal investigators about their individual projects are included, specifically, chemistry (pituitary tumor studies, boron drug development including ...
A source for boron neutron capture therapy (BNCT) comprises a body of photoneutron emitter that includes heavy water and is closely surrounded in heat-imparting relationship by target material; one or more electron linear accelerators for supplying electron radiation having energy of substantially 2 to 10 MeV and for impinging such radiation on the target ...
DOEpatents
We present a conceptual design of a low-energy neutron generator for treatment of brain tumors by boron neutron capture theory (BNCT). The concept is based on a 2.5-MeV proton beam from a radio-frequency quadrupole (RFQ) linac, and the neutrons are produc...
In this work we describe the present status of an ongoing project to develop a tandem-electrostatic-quadrupole (TESQ) accelerator facility for accelerator-based (AB) BNCT at the Atomic Energy Commission of Argentina in Buenos Aires. The project final goal is a machine capable of delivering 30 mA of 2.4 MeV protons to be used in ...
At Kyoto University Research Reactor Institute (KURRI), 275 clinical trials of boron neutron capture therapy (BNCT) have been performed as of March 2006, and the effectiveness of BNCT has been revealed. In order to further develop BNCT, it is desirable to supply accelerator-based epithermal-neutron sources that can ...
The purpose of this study was to evaluate the clinical outcome of BSH-based intra-operative BNCT (IO-BNCT) and BSH and BPA-based non-operative BNCT (NO-BNCT). We have treated 23 glioblastoma patients with BNCT without any additional chemotherapy since ...
The neutron irradiation system for boron neutron capture therapy (BNCT) using compact accelerators installed at hospitals was mainly investigated for the usage of direct neutrons from near-threshold {sup 7}Li(p,n){sup 7}Be, and moderated neutrons from 2.5 MeV {sup 7}Li(p,n){sup 7}Be reactions and other reactions. This kind of system can supply the medical ...
The development of new neutron sources for BNCT applications, based on particle accelerators is currently underway all over the world. Though nuclear reactors were used for a long time as the only neutron source available having the requested flux levels, the accelerator-based ones have recently been investigated ...
Recent interest in the production of epithermal neutrons for use in boron neutron capture therapy (BNCT) has prompted an investigation into the feasibility of generating such neutrons with a tandem cascade accelerator. Accelerator-produced neutrons in the range of roughly 200--800 keV are generated in a lithium compound target via the ...
The use of boron neutron capture therapy for the treatment of deep-seated tumours, such as glioblastoma multiforme, requires neutron beams of suitable energy and intensity. The analysis of the therapeutic gain shows that a high tumour control probability with sublethal dose at healthy tissues can be achieved, in most cases, by using neutron beams of a few keV energy, with a flux of about 109 ...
An accelerator-based BNCT facility is under construction at the Berkeley Lab. An electrostatic-quadrupole (ESQ) accelerator is under development for the production of neutrons via the {sup 7}Li(p,n){sup 7}Be reaction at proton energies between 2.3 and 2.5 MeV. A novel type of power supply, an air-core coupled transformer power supply, ...
A hybrid photoneutron target including natural uranium has been studied for a 20 MeV linear electron accelerator (Linac) based Boron Neutron Capture Therapy (BNCT) facility. In this study the possibility of using uranium to increase the neutron intensity has been investigated by focusing on the time dependence behavior of the build-up ...
A new conceptual design for an accelerator-based boron neutron capture therapy (ABNCT) facility based on the high-current low-energy proton beam driven by the linear accelerator at SARAF (Soreq Applied Research Accelerator Facility) incident on a windowless forced-flow liquid-lithium target, is described. The ...
Neutrons can be produced with low-energy ion accelerators for many applications, such as the characterisation of neutron detectors, the irradiation of biological samples and the study of the radiation damage in electronic devices. Moreover, accelerator-based neutron sources are under development for boron neutron capture therapy ...
An accelerator-based BNCT facility is under development at the Lawrence Berkeley National Laboratory. Neutrons will be produced via the {sup 7}Li(p,n) reaction at proton energies of about 2.5 MeV with subsequent moderation and filtering for shaping epithermal neutron beams for BNCT. Moderator, filter, and shielding assemblies have been ...
The neutronic efficiency of target/filters for accelerator-based BNCT applications is measured by the proton current required to achieve a desirable neutron current at the treatment port (10{sup 9} n/cm{sup 2}/s). In this paper the authors describe two possible targeyt/filter concepts wihch minimize the required current. Both concepts are ...
The Soreq Applied Research Accelerator Facility (SARAF) is based on a superconducting linear accelerator currently being built at the Soreq research center (Israel). The SARAF is planned to generate a 2 mA 4 MeV proton beam during its first year of operation and up to 40 MeV proton or deuteron beam in 2012. The high intensity beam, ...
To realize the accelerator-based boron neutron capture therapy (BNCT) at the Cyclotron and Radioisotope Center of Tohoku University, the feasibility of a cyclotron-based BNCT was evaluated. This study focuses on optimizing the epithermal neutron field with an energy spectrum and intensity suitable for ...
In the frame of the construction of a Tandem Electrostatic Quadrupole Accelerator facility devoted to the Accelerator-Based Boron Neutron Capture Therapy, a Beam Shaping Assembly has been characterized by means of Monte-Carlo simulations and measurements. The neutrons were generated via the {sup 7}Li(p, n){sup 7}Be reaction by irradiating a thick LiF ...
In the frame of the construction of a Tandem Electrostatic Quadrupole Accelerator facility devoted to the Accelerator-Based Boron Neutron Capture Therapy, a Beam Shaping Assembly has been characterized by means of Monte-Carlo simulations and measurements. The neutrons were generated via the 7Li(p, n)7Be reaction by irradiating a thick LiF target with a 2.3 ...
Neutron capture in sup 1 sup 0 B produces energetic alpha particles that have a high linear energy transfer in tissue. This results in higher cell killing and a higher relative biological effectiveness compared to photons. Using suitably designed boron compounds which preferentially localize in cancerous cells instead of healthy tissues, boron neutron capture therapy (BNCT) ...
Neutron capture in 10B produces energetic alpha particles that have a high linear energy transfer in tissue. This results in higher cell killing and a higher relative biological effectiveness compared to photons. Using suitably designed boron compounds which preferentially localize in cancerous cells instead of healthy tissues, boron neutron capture therapy (BNCT) has the ...
known as boron neutron capture therapy (BNCT), the new com- pounds contain the element boron and become- ment to achieve the optimum radiation dose to the tumor while sparing healthy normal cells. While BNCT therapy. Scientists are currently testing the effectiveness of clinical BNCT in the U.S. (Massachu- setts
A new multi-modal Monte-Carlo radiotherapy planning system (developing code: JCDS-FX) is under development at Japan Atomic Energy Agency. This system builds on fundamental technologies of JCDS applied to actual boron neutron capture therapy (BNCT) trials in JRR-4. One of features of the JCDS-FX is that PHITS has been applied to particle transport calculation. PHITS is a ...
There is a generalized perception that the availability of suitable particle accelerators installed in hospitals, as neutron sources, may be crucial for the advancement of Boron Neutron Capture Therapy (BNCT). Progress on an ongoing project to develop a Tandem-ElectroStatic-Quadrupole (TESQ) accelerator for ...
Radio-frequency (RF) driven ion sources are being developed in Lawrence Berkeley National Laboratory (LBNL) for sealed-accelerator-tube neutron generator application. By using a 5-cm-diameter RF-driven multicusp source H{sup +} yields over 95% have been achieved. These experimental findings will enable one to develop compact neutron generators based on the ...
We describe the present status of an ongoing project to develop a Tandem-ElectroStatic-Quadrupole (TESQ) accelerator facility for Accelerator-Based (AB)-BNCT. The project final goal is a machine capable of delivering 30mA of 2.4MeV protons to be used in conjunction with a neutron production target based on the ...
Boron neutron capture therapy (BNCT) is a binary cancer treatment modality in which a boron-containing compound is preferentially loaded into a tumor, followed by irradiation by thermal neutrons. In accelerator-based BNCT, neutrons are produced by charged particle-induced reactions such as 7Li(p,n)7Be. For deeply seated brain tumors, ...
This is the progress report and proposed research objectives for the project entitled An Accelerator Neutron Source for BNCT.'' The progress report is for the time period from July 15, 1990 to date. The proposal is for the upcoming budget period from July 15, 1991 to July 14, 1992. The objectives of this project are to design and test ...
We present a conceptual design of a low-energy neutron generator for treatment of brain tumors by boron neutron capture theory (BNCT). The concept is based on a 2.5-MeV proton beam from a radio-frequency quadrupole (RFQ) linac, and the neutrons are produced by the /sup 7/Li(p,n)/sup 7/Be reaction. A liquid lithium target and modulator assembly are designed ...
It has been shown that the clinical quality of the neutron beam available for boron neutron capture therapy (BNCT) depends strongly on the design of the beam shaping assembly (BSA). The same study showed that a neutron source based on the {sup 7}Li(p,n) reaction, which is induced by protons accelerated to 2.5 MeV, could provide ...
Different materials and proton beam energies have been studied in order to search for an optimized neutron production target and beam shaping assembly for accelerator-based BNCT. The solution proposed in this work consists of successive stacks of Al, polytetrafluoroethylene, commercially known as Teflon, and LiF as moderator and neutron absorber, and Pb as ...
Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at ...
A large fraction of the proposals for accelerator-based boron neutron capture therapy (BNCT) facilities consider neutron sources consisting of 2.5-MeV protons impinging on a {sup 7}Li target. Nevertheless, several studies considered accelerator-target concepts offering a significantly harder neutron spectrum. The harder the source ...
The Idaho National Engineering Laboratory (INEL) has been investigating the feasibility of a concept for an accelerator-based source of epithermal neutrons for BNCT that is based on the use of a two-stage photoneutron production process driven by an electron accelerator. In this concept, relativistic electron beams ...
The DOE-funded accelerator BNCT program at the Massachusetts Institute of Technology has resulted in the only operating accelerator-based epithermal neutron beam facility capable of generating significant dose rates in the world. With five separate beamlines and two different epithermal neutron beam assemblies installed, we are ...
This project report is based on our investigations for thermal design of a heat pipe for removing generated heat resulting from Proton bombardments of a Lithium target for a BNCT application. In our investigation, an integral analysis was employed to inve...
Previously, the authors have developed the in-phantom neutron field assessment parameters T and D (Tumor) for the evaluation of epithermal neutron fields for use in BNCT. These parameters are based on an energy-spectrum- dependent neutron normal-tissue RB...
The use of the 13C(d,n) 14N reaction at Ed=1.5 MeV for accelerator-based boron neutron capture therapy (AB-BNCT) is investigated. Among the deuteron-induced reactions at low incident energy, the 3C(d,n)14N reaction turns out to be one of the best for AB-BNCT because of beneficial materials properties inherent to carbon and its ...
There were three objectives to this project: (1) The development of the 2-D Swan code for the optimization of the nuclear design of facilities for medical applications of radiation, radiation shields, blankets of accelerator-driven systems, fusion facilities, etc. (2) Identification of the maximum beam quality that can be obtained for Boron Neutron Capture Therapy ...
The use of proton and heavy ion beams for radiotherapy is a well established cancer treatment modality in the first world, which is becoming increasingly widespread, due to its clear advantages over conventional photon-based treatments. This strategy is suitable when the tumor is spatially well localized. Also the use of neutrons has tradition. Here Boron Neutron Capture ...
In this paper a fast method to evaluate neutron spectra for brain BNCT is developed. The method is based on an algorithm to calculate dose distribution in the brain, for which a data matrix has been taken into account, containing weighted biological doses per position per incident energy and the incident neutron spectrum to be evaluated. To build the ...
Near-threshold boron neutron capture therapy (BNCT) uses proton energies only tens of rev above the (pan) reaction threshold in lithium in order to reduce the moderation requirements of the neutron source. The goals of this research were to prove the feasibility of this near-threshold concept for BNCT applications, using both calculation and experiment, ...
At BNL, we have evaluated the beam current required to produce a clinical neutron beam for Boron Neutron Capture Therapy (BNCT) with an epithermal neutron flux of 10{sup 12} n/cm{sup 2}/hr. Experiments were carried out on a Van de Graaff accelerator at the Radiological Research Accelerator Facility (RARAF) at Columbia University. A ...
A novel application of the 10B(n, (alpha) )7Li nuclear reaction for the treatment of rheumatoid arthritis is under development. this application, called Boron Neutron Capture Synovectomy (BNCS), is briefly described here and the differences between BNCS and Boron Neutron Capture Therapy (BNCT) are discussed in detail. These differences lead to substantially altered demands on ...
This report is a summary of the progress and research produced for the Idaho National Engineering and Environmental Laboratory (INEEL) Boron Neutron Capture Therapy (BNCT) Research Program for calendar year 1996. Contributions from the individual investigators about their projects are included, specifically, physics: treatment planning software, real-time neutron beam ...
In this article, we will consider several core configurations and run the core calculation with MCNP to obtain the neutrons distribution at THOR. The thermal neutron flux inside the vertical tubes (VT-B-VT-E) and the fast neutron flux in the first row facing to the boron neutron capture therapy (BNCT) facility (I3-I5) were tallied for indication. Based on ...
An accelerator-based neutron irradiation facility employing an electrostatic quadrupole (ESQ) accelerator for Boron Neutron Capture Therapy (BNCT) has been proposed at Lawrence Berkeley National Laboratory. In this dissertation, the properties of an ideal neutron beam for delivering a maximized dose to a glioblastoma multiforme tumor ...
The use of boron neutron capture therapy (BNCT) has been considered for nearly 30 years, and been practiced in Japan since the late 1970`s. Early experiments in the USA were generally nonpromising. However, new boron-containing ligand compounds were developed, which would seek out brain tumors. Concentration levels of the order of 30 micrograms of boron per gram of tissue ...
Two acrylic cube phantoms have been constructed for BNCT applications that allow the depth distribution of neutrons to be measured with miniature {sup 10}BF{sub 3} detectors in 0.5-cm steps beginning at 1-cm depth. Sizes and weights of the cubes are 14 cm, 3.230 kg, and 11 cm, 1.567 kg. Tests were made with the epithermal neutron beam from the patient treatment port of the ...
Boron neutron capture therapy (BNCT) is a bimodal form of radiation therapy for cancer. The first component of this treatment is the preferential localization of the stable isotope {sup 10}B in tumor cells by targeting with boronated compounds. The tumor and surrounding tissue is then irradiated with a neutron beam resulting in thermal neutron/{sup 10}B reactions ({sup ...
BACKGROUND: Boron neutron capture therapy (BNCT) is based on the nuclear reaction that occurs when boron-10 is irradiated with low-energy thermal neutrons to yield high linear energy transfer alpha particles and recoiling lithium-7 nuclei. Clinical interest in BNCT has focused primarily on the treatment of high-grade gliomas and either ...
This report is a summary of the activities conducted in conjunction with the Idaho National Engineering and Environmental Laboratory (INEEL) Boron Neutron Capture Therapy (BNCT) Research Program for calendar year 2000. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, neutron ...
A conceptual design of an inertial electrostatic confinement (IEC) neutron source for boron neutron capture therapy (BNCT) is described. The IEC system produces neutron fusion reactions, where ions are accelerated toward each other by a spherical gridded structure. Significant research and development are needed to scale the system up to the required ...
The usable range of thickness for the solid lithium target in the accelerator-based neutron production for BNCT via the near-threshold 7Li(p,n)7Be reaction was investigated. While the feasibility of using a 7Li-target with thickness equal to that which is required to slow down a mono-energetic 1.900 MeV incident proton to the 1.881 MeV threshold of the ...
The usable range of thickness for the solid lithium target in the accelerator-based neutron production for BNCT via the near-threshold (7)Li(p,n)(7)Be reaction was investigated. While the feasibility of using a (7)Li-target with thickness equal to that which is required to slow down a mono-energetic 1.900 MeV incident proton to the 1.881 MeV threshold of ...
The optimal neutron energy for the treatment of deep-seated tumours using boron neutron capture therapy is studied by analysing various figures of merit. In particular, analysis of the therapeutic gain as a function of the neutron energy indicates that, with the currently available 10B carriers, the most useful neutrons for the treatment of deep-seated tumours, in particular glioblastoma ...
Three moderator materials, AlF{sub 3}/Al, D{sub 2}O and LiF, have been analyzed for clinical usefulness using the reaction {sup 7}Li(p,n) as an accelerator driven neutron source. Proton energies between 2.1 MeV and 2.6 MeV have been investigated. Radiation transport in the reflector/moderator assembly is simulated using the MCNP program. Depth-dose distributions in a head ...
At Kyoto University Research Reactor Institute (KURRI), cyclotron-based epithermal neutron source was installed in December 2008, and the supplementary construction works have been performed. As of December 2010, the various irradiation characteristics important for BNCT were mostly evaluated. The whole body exposure during BNCT ...
This study considers the radiation safety aspects of several designs discussed in a previous report of an accelerator-based source of neutrons, based on the [sup 7]Li(p,n) reaction, for a Boron Neutron Capture Therapy (BNCT) Facility at Lawrence Berkeley National Laboratory (LBNL). determines the optimal radiation shield thicknesses ...
A great advantage of some neutron sources, such as accelerator-produced sources, is that they can be tuned to produce different spectra. Unfortunately, optimization studies are often time-consuming and difficult, as they require a lengthy Monte Carlo simu...
An ideal neutron beam for BNCT is a beam of epithermal neutrons, forward directed, and free of gamma rays and thermal and fast neutrons. Three neutron beams were evaluated, and compared: (1) the operating Brookhaven Medical Research Reactor (BMRR) epither...
A dc electrostatic quadrupole (ESQ) accelerator is capable of producing a 2.5 MeV, 100 mA proton beam for the purpose of generating neutrons for Boron Neutron Capture Therapy. The ESQ accelerator is better than the conventional aperture column in high beam current application due to the presence of stronger transverse field for beam focusing and for ...
The beam shaping assembly design has been investigated in order to improve the epithermal neutron beam for accelerator-based boron neutron capture therapy in intensity and quality, and dosimetric evaluation for the beams has been performed using both mathematical and voxel head phantoms with MCNP runs. The neutron source was assumed to be produced from a conventional 2.5 MeV ...
In this work the D(d,n)3He and 9Be(d,n)10B reactions have been studied in a low-energy regime as neutron sources for skin tumor treatment in the frame of accelerator-based BNCT (AB-BNCT). The total neutron production and the energy and angular distributions for each reaction at different bombarding energies and for the thick targets ...
A new ultrahigh-resolution photoemission electron microscope called PEEM3 is being developed and built at the Advanced Light Source (ALS). An electron mirror combined with a much-simplified magnetic dipole separator is to be used to provide simultaneous correction of spherical and chromatic aberrations. It is installed on an elliptically polarized undulator (EPU) beamline, and will be operated ...
A new target concept termed Discs Incorporating Sector Configured Orbiting Sources (DISCOS), is proposed for spallation applications, including BNCT (Boron Neutron Capture Therapy). In the BNCT application a proton beam impacts a sequence of ultra thin lithium DISCOS targets to generate neutrons by the {sup 7}Li(p,n){sup 7}Be reaction. The proton beam ...
In this report we discuss some issues considered in selecting initial protocols for boron neutron capture therapy (BNCT) of human glioblastoma multiforme. First the tolerance of normal tissues, especially the brain, to the radiation field. Radiation doses limits were based on results with human and animal exposures. Estimates of tumor control doses were ...
An ideal neutron beam for BNCT is a beam of epithermal neutrons, forward directed, and free of gamma rays and thermal and fast neutrons. Three neutron beams were evaluated, and compared: (1) the operating Brookhaven Medical Research Reactor (BMRR) epithermal beam, (2) the designed Missouri University Research Reactor (MURR) epithermal beam, and (3) the ...
The {sup 7}Li(p,n){sup 7}Be reaction has been investigated as an accelerator-driven neutron source for proton energies between 2.1 and 2.6 MeV. Epithermal neutron beams shaped by three moderator materials, Al/AlF{sub 3}, {sup 7}LiF, and D{sub 2}O, have been analyzed and their usefulness for boron neutron capture therapy (BNCT) treatments evaluated. ...
The article focuses on the methodology for a realistic evaluation of the dose and fluence distributions in Neutron Capture Therapy (NCT), based on the Treatment Planning System (TPS) that takes into account the real macroscopic distribution of the neutron capturer. The neutron capturers considered in the present study are 10B and 157Gd, used in BNCT and ...
Boron Neutron Capture Therapy (BNCT) is currently performed on patients at nuclear reactors. At the same time the international BNCT community is engaged in the development of alternative facilities for in-hospital treatments. This paper investigates the potential of a novel high-output D D neutron generator, developed at Lawrence Berkeley National ...
The aim of the present work was creating a virtual phantom of a human head for BNCT, as a part of the BNCT programme project. This model is an amplification of the simple model described in earlier publications. It takes into account the major head organs as well as the scalp and skull. The chemical composition of all tissues was modelled according to the ...
In order to generate epithermal neutrons for boron neutron capture therapy (BNCT), we proposed the method of filtering and moderating fast neutrons, which are emitted from the reaction between a beryllium target and 30 MeV protons accelerated by a cyclotron, using an optimum moderator system composed of iron, lead, aluminum, calcium fluoride, and enriched ...
A dc electrostatic quadrupole (ESQ) accelerator is capable of producing a 2.5 MeV, 100 mA proton beam for the purpose of generating neutrons for Boron Neutron Capture Therapy. The ESQ accelerator is better than the conventional aperture column in high bea...
A DC electrostatic quadrupole (ESQ) accelerator is capable of producing a 2.5 MeV, 100 mA proton beam for the purpose of generating epithermal neutrons for Boron Neutron Capture Therapy. The ESQ accelerator has a strong transverse field for beam focusing ...
The �TAORMINA project� developed a new method for Boron Neutron Capture Therapy (BNCT) of human multifocal unresectable liver metastases based on whole liver ex-situ BNCT mediated by boronophenylalanine (BPA), followed by whole liver autograft. This technique involved a high risk, prolonged anhepatic phase. The Roffo Institute ...
This study demonstrates the characterization of proton spot scanning on a Li target assembly for accelerator-based BNCT from the viewpoint of heat removal and material strength. These characteristics are investigated as to their dependence on the Li target thickness, considering that the Cu backing plate has more suitable heat removal properties than Li. ...
An accelerator-driven thermal neutron facility for boron neutron capture therapy of skin melanoma is currently under construction at the Legnaro National Laboratories, Italy. The installation relies on the production of neutrons from a thick beryllium target bombarded with 5 MeV protons. A complete set of double differential data, i.e. angle- and energy-differential neutron ...
An innovative accelerator-based neutron source for BNCT has just started operation at the Budker Institute of Nuclear Physics, Novosibirsk. One of the main elements of the facility is a lithium target producing neutrons via the threshold (7)Li(p,n)(7)Be reaction at 25 kW proton beam with energies of 1.915 MeV or 2.5 MeV. The design of an optimal target and ...
Tsing Hua open-pool reactor (THOR) at Tsing Hua University in Taiwan has been used to investigate the feasibility and to enhance the technology of boron neutron capture therapy (BNCT) for years. A rebuilt epithermal beam port for BNCT at THOR was finished in the summer of 2004, and then researches and experiments were performed to hasten the first clinical ...
Calculations of the epithermal-neutron yield of photoneutrons from a uranium-beryllium converter using a 27 MeV electron linear accelerator have been investigated. In this concept, relativistic electron beams from a 30 MeV LINAC impinge upon a small uranium sphere surrounded by a cylindrical tank of circulating heavy water (D2O) nested in a beryllium cube. The photo-fission ...
Two new concepts, NIFTI and DISCOS, are described. These concepts enable the efficient production of epithermal neutrons for BNCT (Boron Neutron Capture Therapy) medical treatment, utilizing a low current, low energy proton beam impacting on a lithium target. The NIFTI concept uses an iron layer that strongly impedes the transmission of neutrons with energies above 24 KeV. ...
Some remarkable advances have been made in the last years on the SPES-BNCT project of the Istituto Nazionale di Fisica Nucleare (INFN) towards the development of the accelerator-driven thermal neutron beam facility at the Legnaro National Laboratories (LNL), aimed at the BNCT experimental treatment of extended skin melanoma. The ...
PhoNeS (Photo Neutron Source) is an INFN project devoted to the optimization of the neutron production and moderation in radiotherapy linear accelerators. LinAcs producing high energy (15 25 MeV) photon beams are becoming widespread. At this energy neutron photo-production is unavoidable and the neutron dose must be controlled and reduced during normal radiotherapy. A ...
Boron neutron capture therapy (BNCT) is a binary treatment modality that can selectively irradiate tumor tissue. BNCT uses drugs containing a stable isotope of boron, {sup 10}B, to sensitize tumor cells to irradiation by low-energy (thermal) neutrons. The interaction of the {sup 10}B with a thermal neutron (neutron capture) causes the {sup 10}B nucleus to ...
Mast cell (MC) activation in the hamster cheek pouch cancerization model is associated with the increase in tumor cell proliferation, mediated in turn by tryptase, a protease released from mast cell granules after activation. Tryptase induces tumor cell proliferation through the activation of PAR-2 (protease activated receptor-2) on the plasma membrane of carcinoma cells. The therapeutic success ...
In one embodiment there is provided an application of the {sup 10}B(n,{alpha}){sup 7}Li nuclear reaction or other neutron capture reactions for the treatment of rheumatoid arthritis. This application, called Boron Neutron Capture Synovectomy (BNCS), requires substantially altered demands on neutron beam design than for instance treatment of deep seated tumors. Considerations for neutron beam ...
In one embodiment there is provided an application of the .sup.10 B(n,.alpha.).sup.7 Li nuclear reaction or other neutron capture reactions for the treatment of rheumatoid arthritis. This application, called Boron Neutron Capture Synovectomy (BNCS), requires substantially altered demands on neutron beam design than for instance treatment of deep seated tumors. Considerations for neutron beam ...
The development of Boron Neutron Capture Therapy (BNCT) has been progressing in both ^{10 }B compound development and testing and neutron beam delivery. Animal tests are now in progress with several ^{10}B compounds and once the results of these animal tests are promising, patient trials can be initiated. The objective of this study is to create a treatment planning method ...
Boron Neutron Capture Therapy (BNCT) is one of the potent cancer radiotherapies using nuclear reaction between (10)B atoms and the neutron. Whether BNCT will succeed or not depends on tumor selective delivery of (10)B compounds. ?-Poly-L-lysine is a naturally occurring polyamine characterized by the peptide linkages between the carboxyl and ?-amino groups ...
In an earlier study a relative simple mathematical model has been constructed to simulate the energy transfer on a cellular scale and thus gain insight in the fundamental processes of BNCT. Based on this work, a more realistic micro dosimetry model is dev...
... boronated drug(s) and subsequent activation by neutrons. Brain tumors, skin melanoma, and tumors of head and neck have been treated with BNCT. Boron carrier drugs ... ...
NBII National Biological Information Infrastructure
Boron Neutron Capture Therapy (BNCT) is a binary method of cancer therapy based on the capture of neutrons by a boron-l0 atom. Cytotoxic (sup 7) Linuclei and alpha-particles are emitted, with a range in tissue of 9 and 5 micrometers, respectively, about o...
Calculations of radiation flux and dose distributions for Boron Neutron Capture Therapy (BNCT) of brain tumors are typically performed using sophisticated three-dimensional analytical models based on either a homogeneous approximation or a simplified few-...
In Boron Neutron Capture Therapy (BNCT) of malignant brain tumors, the energy dependence of a clinically relevant Relative Biological Effectiveness (RBE) for epithermal neutrons, RBE(En), is important in neutron field design. In the first half of this paper, we present the development of an expression for the energy dependent normal-tissue RBE, RBE(En). We then calculate a ...
Currently available epithermal neutron beams at the Massachusetts Institute of Technology (MIT) are not sufficiently intense to meet the anticipated demand for boron neutron capture therapy (BNCT) treatments if initial, currently in progress clinical trials of BNCT prove successful. Indeed, they are not really adequate for extensive (phase-III) clinical ...
In this study, microdosimetric energy distributions of secondary charged particles from the (10)B(n,?)(7)Li reaction in boron-neutron capture therapy (BNCT) field were calculated using the Particle and Heavy Ion Transport code System (PHITS). The PHITS simulation was performed to reproduce the geometrical set-up of an experiment that measured the microdosimetric energy ...
Fast neutron radiotherapy (FNT) can be combined with boron neutron capture therapy (BNCT). The selective incremental absorbed dose in the target volume that is thus obtained may be sufficient to produce a significant improvement in tumor control probability in some cases. Potential applications include certain non-small-cell lung tumors; head and neck tumors; prostate tumors; ...
Accurate delivery of the prescribed dose during clinical BNCT requires knowledge (or reasonably valid assumptions) about the boron concentrations in tumor and normal tissues. For conversion of physical dose (Gy) into photon-equivalent dose (Gy-Eq), relative biological effectiveness (RBE) and/or compound-adjusted biological effectiveness (CBE) factors are required for each ...
Boron Neutron Capture Therapy (BNCT) is a promising bimodal radiation therapy used primarily for highly malignant gliomas. Specification of the absorbed and biologically effective dose in BNCT is a primary concern in the implementation of this therapeutic technique. Providing accurate dosimetry for the complex mixed field encountered in ...
A single-photon emission computed tomography [SPECT] imaging agent that is an analogue of a boron carrier for boron neutron-capture therapy [BNCT] of cerebral gliomas would be useful for assessing the kinetics of boron uptake in tumors and in the surrounding brain tissues noninvasively. BNCT is based on the interaction of thermalized ...
A new multi-modal Monte-Carlo radiation treatment planning system is under development at Japan Atomic Energy Agency. This system (developing code: JCDS-FX) builds on fundamental technologies of JCDS. JCDS was developed by JAEA to perform treatment planning of boron neutron capture therapy (BNCT) which is being conducted at JRR-4 in JAEA. JCDS has many advantages ...
Clinical trials to determine the efficacy of boron neutron capture therapy (BNCT) have been initiated in the United States at the Deaconess Hospital, Harvard Medical School, and the Massachusetts Institute of Technology (MIT) for the treatment of melanomas and glioblastomas and at Brookhaven National Laboratory (BNL) for the treatment of glioblastomas. Medical physicists at ...
Boron neutron capture therapy (BNCT) is based on the nuclear reaction that occurs when boron-10 is irradiated with low-energy thermal neutrons to yield alpha particles and recoiling lithium-7 nuclei. High-grade astrocytomas, glioblastoma multiforme, and metastatic brain tumors constitute a major group of neoplasms for which there is no effective treatment. ...
We previously demonstrated the therapeutic efficacy of different boron neutron capture therapy (BNCT) protocols in an experimental model of oral cancer. BNCT is based on the selective accumulation of (10)B carriers in a tumor followed by neutron irradiation. Within the context of exploring the potential therapeutic efficacy of ...
A high-current (>20 mA) dc proton accelerator is being developed for applications such as boron neutron capture therapy (BNCT) and the detection of explosive materials by nuclear resonance absorption (NRA) of gamma radiation. The high-voltage dc accelerator (adjustable between 1.4 and 2.8 MeV) will be a single-ended industrial ...
A prototype of a compact Liquid-Lithium Target (LiLiT), which will possibly constitute an accelerator-based intense neutron source for Boron Neutron Capture Therapy (BNCT) in hospitals, was built. The LiLiT setup is presently being commissioned at Soreq Nuclear Research Center (SNRC). The liquid-lithium target will produce neutrons through the ...
BNCT is a tumour treatment based on thermal-neutron irradiation of tissues enriched with 10B, which according to the 10B(n, )7Li reaction produces particles with high Linear Energy Transfer and short range. Since this treatment can deliver a therapeutic tumour dose sparing normal tissues, BNCT represents an alternative for diffuse ...
Boron-neutron capture therapy (BNCT) is an experimental radiation treatment modality used for highly malignant tumor treatments. Prior to irradiation with low energetic neutrons, a 10B compound is located selectively in the tumor cells. The effect of the treatment is based on the high LET radiation released in the {sup 10}B(n,{alpha}){sup 7}Li reaction ...
Radiochromic gel dosimeters in form of layers based on Fricke solution have shown to be a valuable method for in-phantom dose measurements in a mixed BNCT radiation field. Using dosimeters with different isotopic composition it is possible to determine bidimensional distribution of the different dose components. In the last years, the method has been ...
For the prediction of decay concentration profiles of the p-boronophenylalanine (BPA) in blood during BNCT treatment, a method is suggested based on Kohonen neural networks. The results of a model trained with the concentration profiles from the literature are described. The prediction of the model was validated by the leave-one-out method. Its robustness ...
Theoretical investigations of plasma-based accelerators and other advanced accelerator concepts. The focus of the work was on the development of plasma based and structure based accelerating concepts, including laser-plasma, plasma channel, and microwave driven plasma ...
Positron emission tomography (PET) has become a key imaging tool in clinical practice and biomedical research to quantify and study biochemical processes in vivo. Physiologically active compounds are tagged with positron emitters (e.g. (18)F, (11)C, (124)I) while maintaining their biological properties, and are administered intravenously in tracer amounts (10(-9)-10(-12)M quantities). The recent ...
The development of a secondary ion mass spectrometry (SIMS) based technique of Ion Microscopy in boron neutron capture therapy (BNCT) was the main goal of this project, so that one can study the subcellular location of boron-10 atoms and their partitioning between the normal and cancerous tissue. This information is fundamental for the screening of ...
The technical design of the research reactor IRT in Sofia is in progress. It includes an arrangement for a BNCT facility for tumor treatment. Modeling of geometry and material composition of filter/collimator for the BNCT beam tube on IRT has been carried out following the beam tube configuration of the Massachusetts Institute of Technology Reactor ...
Measurements of in-phantom dose distributions and images are important for Boron Neutron Capture Therapy treatment planning. The method for spatial determination of absorbed doses in thermal or epithermal neutron fields, based on Fricke-xylenol-orange-infused gel dosimeters in form of layers, has revealed to be very reliable, as gel layer dosimeters give the possibility of ...
Boron neutron capture therapy (BNCT) is an anticancer therapy based on the incorporation of (10)B in tumors, followed by neutron irradiation. Recently, the synthesis and delivery of new boronated compounds have been recognized as some of the main challenges in BNCT application. Here, we report on the use of liposomes as carriers for ...
The collision type central to BNCT is (10)B(n, alpha)(7)Li, however, other types of nuclear reactions also take place in the patient. In addition to the major elements (H, C, N, O), minor elements such as Na, Mg, P, S, Cl, K, Ca and Fe present in body tissues also interact in neutron collisions. Detailed accounting of the above not only provides a better understanding of ...
The focus of this study is the indentification of key feasibility issues for the use of non-reactor neutron sources for Boron Neutron Capture Therapy (BNCT). Of the non-reactor neutron sources surveyed, the /sup 7/Li(p,n) reaction appears to be the most favorable for producing epithermal neutrons for BNCT, and RFQ accelerators are best ...
Abstract We previously demonstrated the therapeutic efficacy of different boron neutron capture therapy (BNCT) protocols in an experimental model of oral cancer. BNCT is based on the selective accumulation of 10B carriers in a tumor followed by neutron irradiation. Within the context of exploring the potential therapeutic efficacy of ...
Radiation sensitive polymer gels are among the most promising three-dimensional dose verification tools developed to date. Polymer gel dosimeter known by the acronym MAGIC has been tested for evaluation of its use in boron neutron capture (BNCT) dosimetry. We irradiated a large (diameter 10 cm, length 20 cm) cylindrical gel phantom in the epithermal neutron beam of the Finnish ...
Protecting the facility personnel and the general public from radiation exposure is a primary safety concern of an accelerator-based epithermal neutron irradiation facility. This work makes an attempt at answering the questions {open_quotes}How much?{close_quotes} and {open_quotes}What kind?{close_quotes} of shielding will meet the occupational limits of such a facility. ...
Since 1998, we are performing clinical studies on treatment of GBM using conventional fractionated photon radiation therapy (CRT), proton beam therapy (PBT) or boron neutron capture therapy (BNCT). We investigated whether these radiation modalities improves the survival of patients with GBM. Sixty-eight cases of newly diagnosed GBM have been treated in our institution. After ...
Recently, a new application of boron neutron capture therapy (BNCT) treatment has been introduced. Results have indicated that liver tumors can be treated by BNCT after removal of the liver from the body. At Lawrence Berkeley National Laboratory, compact neutron generators based on (2)H(d,n)(3)He (D-D) or (3)H(t,n)(4)He (D-T) fusion ...
We report the investigation of new organic complexes containing a magnetic moment (Gd-based molecular nanomagnets), which can serve the double purpose of acting as boron neutron capture therapy (BNCT) agents, and at the same time act as contrast agents to detect the molecule in the tissue by a proton magnetic resonance imaging (MRI). We also explore the ...
The phase II trial has been prepared to assess the effectiveness of BPA (250mg/kg)-based NCT combined with X-ray irradiation and temozolomide (75mg/m(2)) for the treatment of newly diagnosed GBM. BPA uptake is determined by (18)F-BPA-PET and/or (11)C-MET-PET, and a tumor with the lesion to normal ratio of 2 or more is indicated for BNCT. The maximum normal ...
The specific aims of the research proposal were as follows: (1) To design and construct small volume tissue equivalent proportional counters for the dosimetry and microdosimetry of high intensity thermal and epithermal neutron beams used in BNCT, and of modified fast neutron beams designed for boron neutron capture enhanced fast neutron therapy (BNCEFNT). (2) To develop ...
Boron Neutron Capture Therapy [BNCT] is a binary method of cancer therapy based on the capture of neutrons by a boron-10 atom [{sup 10}B]. Cytotoxic {sup 7}Li nuclei and {alpha}-particles are emitted, with a range in tissue of 9 and 5 {micro}m, respectively, about one cell diameter. The major obstacle to clinically viable BNCT is the ...
PhoNeS (photo neutron source) is a project aimed at the production and moderation of neutrons by exploiting high energy linear accelerators, currently used in radiotherapy. A feasibility study has been carried out with the scope in mind to use the high energy photon beams from these accelerators for the production of neutrons suitable for boron neutron ...
... ACCELERATION TOLERANCE, COMPUTER PROGRAMS, DATA BASES, MATHEMATICAL MODELS, STATISTICAL INFERENCE, LOADS ...
DTIC Science & Technology
Tables for acceleration terminology equivalents based on human and vehicle angular and linear motion
NASA Technical Reports Server (NTRS)
This project report is based on our investigations for thermal design of a heat pipe for removing generated heat resulting from Proton bombardments of a Lithium target for a BNCT application. In our investigation, an integral analysis was employed to investigate the vapor an liquid flow in a flat plate heat pipe heated asymmetrically for removal of the 75 ...
Intraosseous benign notochordal cell tumor (BNCT) is a lesion postulated to be of notochordal cell origin. BNCT has recently been recognized as a potential precursor of classic chordoma, a rare malignant neoplasm usually presenting in the sacrococcygeal region, skull base, or mobile spine. Extra-axial chordoma is extremely rare, and ...
To carry out boron neutron capture therapy (BNCT) clinical trials based on accurate dosimetry of several dose components given to a patient, we had developed the JAERI computational dosimetry system (JCDS), which can determine the absorbed doses by numerical simulation. The verification results of initial version of JCDS indicated that JCDS causes ...
Dose planning in boron neutron capture therapy (BNCT) is a complex problem and requires sophisticated numerical methods. In the framework of the Finnish BNCT project, new deterministic three-dimensional radiation transport code MultiTrans SP3 has been developed at VTT Chemical Technology, based on a novel application of the tree ...
The quality of the radiotherapic treatment depends strongly on the capability to measure the dose released in the treated volume and the one absorbed by the surrounding volumes, which is mainly due to the scattered radiation produced by the primary beam interaction with the accelerator collimating system. Radiotherapy linear accelerators produce electron ...