Sample records for acceptance testing plan

  1. Emperical Tests of Acceptance Sampling Plans

    NASA Technical Reports Server (NTRS)

    White, K. Preston, Jr.; Johnson, Kenneth L.

    2012-01-01

    Acceptance sampling is a quality control procedure applied as an alternative to 100% inspection. A random sample of items is drawn from a lot to determine the fraction of items which have a required quality characteristic. Both the number of items to be inspected and the criterion for determining conformance of the lot to the requirement are given by an appropriate sampling plan with specified risks of Type I and Type II sampling errors. In this paper, we present the results of empirical tests of the accuracy of selected sampling plans reported in the literature. These plans are for measureable quality characteristics which are known have either binomial, exponential, normal, gamma, Weibull, inverse Gaussian, or Poisson distributions. In the main, results support the accepted wisdom that variables acceptance plans are superior to attributes (binomial) acceptance plans, in the sense that these provide comparable protection against risks at reduced sampling cost. For the Gaussian and Weibull plans, however, there are ranges of the shape parameters for which the required sample sizes are in fact larger than the corresponding attributes plans, dramatically so for instances of large skew. Tests further confirm that the published inverse-Gaussian (IG) plan is flawed, as reported by White and Johnson (2011).

  2. 49 CFR 232.505 - Pre-revenue service acceptance testing plan.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Pre-revenue service acceptance testing plan. 232... § 232.505 Pre-revenue service acceptance testing plan. (a) General; submission of plan. Except as... its system the operating railroad or railroads shall submit a pre-revenue service acceptance testing...

  3. 49 CFR 238.111 - Pre-revenue service acceptance testing plan.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the times and places of the pre-revenue service tests to permit FRA observation of such tests. For... 49 Transportation 4 2010-10-01 2010-10-01 false Pre-revenue service acceptance testing plan. 238... and General Requirements § 238.111 Pre-revenue service acceptance testing plan. (a) Passenger...

  4. 49 CFR 238.111 - Pre-revenue service acceptance testing plan.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... the times and places of the pre-revenue service tests to permit FRA observation of such tests. For... 49 Transportation 4 2011-10-01 2011-10-01 false Pre-revenue service acceptance testing plan. 238... and General Requirements § 238.111 Pre-revenue service acceptance testing plan. (a) Passenger...

  5. 49 CFR 238.111 - Pre-revenue service acceptance testing plan.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... the times and places of the pre-revenue service tests to permit FRA observation of such tests. For... 49 Transportation 4 2012-10-01 2012-10-01 false Pre-revenue service acceptance testing plan. 238... and General Requirements § 238.111 Pre-revenue service acceptance testing plan. (a) Passenger...

  6. 49 CFR 238.111 - Pre-revenue service acceptance testing plan.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... the times and places of the pre-revenue service tests to permit FRA observation of such tests. For... 49 Transportation 4 2014-10-01 2014-10-01 false Pre-revenue service acceptance testing plan. 238... and General Requirements § 238.111 Pre-revenue service acceptance testing plan. (a) Passenger...

  7. 49 CFR 238.111 - Pre-revenue service acceptance testing plan.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... the times and places of the pre-revenue service tests to permit FRA observation of such tests. For... 49 Transportation 4 2013-10-01 2013-10-01 false Pre-revenue service acceptance testing plan. 238... and General Requirements § 238.111 Pre-revenue service acceptance testing plan. (a) Passenger...

  8. 49 CFR 232.505 - Pre-revenue service acceptance testing plan.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... acceptance tests; (3) Correct any safety deficiencies identified by FRA in the design of the equipment or in... principal test objectives shall be to demonstrate that the equipment meets the safety design and performance... 49 Transportation 4 2013-10-01 2013-10-01 false Pre-revenue service acceptance testing plan. 232...

  9. 49 CFR 232.505 - Pre-revenue service acceptance testing plan.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... acceptance tests; (3) Correct any safety deficiencies identified by FRA in the design of the equipment or in... principal test objectives shall be to demonstrate that the equipment meets the safety design and performance... 49 Transportation 4 2012-10-01 2012-10-01 false Pre-revenue service acceptance testing plan. 232...

  10. 49 CFR 232.505 - Pre-revenue service acceptance testing plan.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... acceptance tests; (3) Correct any safety deficiencies identified by FRA in the design of the equipment or in... principal test objectives shall be to demonstrate that the equipment meets the safety design and performance... 49 Transportation 4 2014-10-01 2014-10-01 false Pre-revenue service acceptance testing plan. 232...

  11. 49 CFR 232.505 - Pre-revenue service acceptance testing plan.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... acceptance tests; (3) Correct any safety deficiencies identified by FRA in the design of the equipment or in... principal test objectives shall be to demonstrate that the equipment meets the safety design and performance... 49 Transportation 4 2011-10-01 2011-10-01 false Pre-revenue service acceptance testing plan. 232...

  12. Transit bus stop pedestrian warning application : acceptance test plan : final report.

    DOT National Transportation Integrated Search

    2016-10-14

    This document is the Acceptance Test Plan for the Transit Bus Stop Pedestrian Warning (TSPW) application. This report describes the test and demonstration plan to verify that the application meets its functional and performance requirements.

  13. LIMS user acceptance testing.

    PubMed

    Klein, Corbett S

    2003-01-01

    Laboratory Information Management Systems (LIMS) play a key role in the pharmaceutical industry. Thorough and accurate validation of such systems is critical and is a regulatory requirement. LIMS user acceptance testing is one aspect of this testing and enables the user to make a decision to accept or reject implementation of the system. This paper discusses key elements in facilitating the development and execution of a LIMS User Acceptance Test Plan (UATP).

  14. General Mission Analysis Tool (GMAT) Acceptance Test Plan [Draft

    NASA Technical Reports Server (NTRS)

    Dove, Edwin; Hughes, Steve

    2007-01-01

    The information presented in this Acceptance Test Plan document shows the current status of the General Mission Analysis Tool (GMAT). GMAT is a software system developed by NASA Goddard Space Flight Center (GSFC) in collaboration with the private sector. The GMAT development team continuously performs acceptance tests in order to verify that the software continues to operate properly after updates are made. The GMAT Development team consists of NASA/GSFC Code 583 software developers, NASA/GSFC Code 595 analysts, and contractors of varying professions. GMAT was developed to provide a development approach that maintains involvement from the private sector and academia, encourages collaborative funding from multiple government agencies and the private sector, and promotes the transfer of technology from government funded research to the private sector. GMAT contains many capabilities, such as integrated formation flying modeling and MATLAB compatibility. The propagation capabilities in GMAT allow for fully coupled dynamics modeling of multiple spacecraft, in any flight regime. Other capabilities in GMAT inclucle: user definable coordinate systems, 3-D graphics in any coordinate system GMAT can calculate, 2-D plots, branch commands, solvers, optimizers, GMAT functions, planetary ephemeris sources including DE405, DE200, SLP and analytic models, script events, impulsive and finite maneuver models, and many more. GMAT runs on Windows, Mac, and Linux platforms. Both the Graphical User Interface (GUI) and the GMAT engine were built and tested on all of the mentioned platforms. GMAT was designed for intuitive use from both the GUI and with an importable script language similar to that of MATLAB.

  15. Specific test and evaluation plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hays, W.H.

    1998-03-20

    The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made to the 241-AX-B Valve Pit by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation Plan (TEP). Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities), Factory Acceptance Tests (FATs), installation tests and inspections, Construction Acceptance Tests (CATs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), andmore » Operational Test Procedures (OTPs). It should be noted that POTPs are not required for testing of the transfer line addition. The STEP will be utilized in conjunction with the TEP for verification and validation.« less

  16. Sharing Data between Mobile Devices, Connected Vehicles and Infrastructure Task 10: D2X Hub Prototype Acceptance Test Plan and Summary Report.

    DOT National Transportation Integrated Search

    2017-10-27

    This Devices to Everything (D2X) Acceptance Test Plan (ATP) and Summary Report provides the plan, test cases, and test procedures that were used to verify Prototype System (version 2.0) system requirements, as well as a summary of results of the test...

  17. Sharing Data between Mobile Devices, Connected Vehicles and Infrastructure Task 6: Prototype Acceptance Test Summary Report

    DOT National Transportation Integrated Search

    2017-10-30

    The Task 6 Prototype Acceptance Test Summary Report summarizes the results of Acceptance Testing carried out at Battelle facilities in accordance with the Task 6 Acceptance Test Plan. The Acceptance Tests were designed to verify that the prototype sy...

  18. Acceptance testing for PACS: from methodology to design to implementation

    NASA Astrophysics Data System (ADS)

    Liu, Brent J.; Huang, H. K.

    2004-04-01

    Acceptance Testing (AT) is a crucial step in the implementation process of a PACS within a clinical environment. AT determines whether the PACS is ready for clinical use and marks the official sign off of the PACS product. Most PACS vendors have Acceptance Testing (AT) plans, however, these plans do not provide a complete and robust evaluation of the full system. In addition, different sites will have different special requirements that vendor AT plans do not cover. The purpose of this paper is to introduce a protocol for AT design and present case studies of AT performed on clinical PACS. A methodology is presented that includes identifying testing components within PACS, quality assurance for both functionality and performance, and technical testing focusing on key single points-of-failure within the PACS product. Tools and resources that provide assistance in performing AT are discussed. In addition, implementation of the AT within the clinical environment and the overall implementation timeline of the PACS process are presented. Finally, case studies of actual AT of clinical PACS performed in the healthcare environment will be reviewed. The methodology for designing and implementing a robust AT plan for PACS was documented and has been used in PACS acceptance tests in several sites. This methodology can be applied to any PACS and can be used as a validation for the PACS product being acquired by radiology departments and hospitals. A methodology for AT design and implementation was presented that can be applied to future PACS installations. A robust AT plan for a PACS installation can increase both the utilization and satisfaction of a successful implementation of a PACS product that benefits both vendor and customer.

  19. UGV acceptance testing

    NASA Astrophysics Data System (ADS)

    Kramer, Jeffrey A.; Murphy, Robin R.

    2006-05-01

    With over 100 models of unmanned vehicles now available for military and civilian safety, security or rescue applications, it is important to for agencies to establish acceptance testing. However, there appears to be no general guidelines for what constitutes a reasonable acceptance test. This paper describes i) a preliminary method for acceptance testing by a customer of the mechanical and electrical components of an unmanned ground vehicle system, ii) how it has been applied to a man-packable micro-robot, and iii) discusses the value of testing both to ensure that the customer has a workable system and to improve design. The test method automated the operation of the robot to repeatedly exercise all aspects and combinations of components on the robot for 6 hours. The acceptance testing process uncovered many failures consistent with those shown to occur in the field, showing that testing by the user does predict failures. The process also demonstrated that the testing by the manufacturer can provide important design data that can be used to identify, diagnose, and prevent long-term problems. Also, the structured testing environment showed that sensor systems can be used to predict errors and changes in performance, as well as uncovering unmodeled behavior in subsystems.

  20. Development and application of an acceptance testing model

    NASA Technical Reports Server (NTRS)

    Pendley, Rex D.; Noonan, Caroline H.; Hall, Kenneth R.

    1992-01-01

    The process of acceptance testing large software systems for NASA has been analyzed, and an empirical planning model of the process constructed. This model gives managers accurate predictions of the staffing needed, the productivity of a test team, and the rate at which the system will pass. Applying the model to a new system shows a high level of agreement between the model and actual performance. The model also gives managers an objective measure of process improvement.

  1. Secondary Waste Cast Stone Waste Form Qualification Testing Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Westsik, Joseph H.; Serne, R. Jeffrey

    2012-09-26

    The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is being constructed to treat the 56 million gallons of radioactive waste stored in 177 underground tanks at the Hanford Site. The WTP includes a pretreatment facility to separate the wastes into high-level waste (HLW) and low-activity waste (LAW) fractions for vitrification and disposal. The LAW will be converted to glass for final disposal at the Integrated Disposal Facility (IDF). Cast Stone – a cementitious waste form, has been selected for solidification of this secondary waste stream after treatment in the ETF. The secondary-waste Cast Stone waste form must be acceptablemore » for disposal in the IDF. This secondary waste Cast Stone waste form qualification testing plan outlines the testing of the waste form and immobilization process to demonstrate that the Cast Stone waste form can comply with the disposal requirements. Specifications for the secondary-waste Cast Stone waste form have not been established. For this testing plan, Cast Stone specifications are derived from specifications for the immobilized LAW glass in the WTP contract, the waste acceptance criteria for the IDF, and the waste acceptance criteria in the IDF Permit issued by the State of Washington. This testing plan outlines the testing needed to demonstrate that the waste form can comply with these waste form specifications and acceptance criteria. The testing program must also demonstrate that the immobilization process can be controlled to consistently provide an acceptable waste form product. This testing plan also outlines the testing needed to provide the technical basis for understanding the long-term performance of the waste form in the disposal environment. These waste form performance data are needed to support performance assessment analyses of the long-term environmental impact of the secondary-waste Cast Stone waste form in the IDF« less

  2. Apollo experience report environmental acceptance testing

    NASA Technical Reports Server (NTRS)

    Laubach, C. H. M.

    1976-01-01

    Environmental acceptance testing was used extensively to screen selected spacecraft hardware for workmanship defects and manufacturing flaws. The minimum acceptance levels and durations and methods for their establishment are described. Component selection and test monitoring, as well as test implementation requirements, are included. Apollo spacecraft environmental acceptance test results are summarized, and recommendations for future programs are presented.

  3. Analysis of Survivor Benefit Plan - Acceptance and Comparison with Private Sector

    DTIC Science & Technology

    1989-01-01

    I COPY AIU WAR COLLEGE ,.SEARCH REPORT ,YSIS OF SURVIVOR BENEFIT PLAN-__CCEPTANCE ’-U AND COMPARISON WITH PRIVATE SECTOR LIEUENNT COLONEL JOHN R...AAA AIR WAR COLLEGE AIR UNIVERSITY ANALYSIS OF SURVIVOR BENEFIT PLAN--ACCEPTANCE AND COMPARISON WITH PRIVATE SECTOR by John R. Adams Lieutenant...Survivor Benefit Plan (SBP)--Acceptance and Comparison With Private Sector . AUTHORS: John R. Adams, Lieutenant Colonel, USAF; Daniel 3. Kohn

  4. Project W-320 acceptance test report for AY-farm electrical distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bevins, R.R.

    1998-04-02

    This Acceptance Test Procedure (ATP) has been prepared to demonstrate that the AY-Farm Electrical Distribution System functions as required by the design criteria. This test is divided into three parts to support the planned construction schedule; Section 8 tests Mini-Power Pane AY102-PPI and the EES; Section 9 tests the SSS support systems; Section 10 tests the SSS and the Multi-Pak Group Control Panel. This test does not include the operation of end-use components (loads) supplied from the distribution system. Tests of the end-use components (loads) will be performed by other W-320 ATPs.

  5. Advanced On-the-Job Training System: Master Test Plan

    DTIC Science & Technology

    1990-05-01

    synonymous with program evaluation and consists of a plan to evaluate AOTS with regard to assessment of the four crit’cal issues of system compliance...acceptance, performance and suitability. Within the MTP, these critical issues are assessed at subcomponent, component, and subsystem levels. 14. SUBJECT...Master Test Plan is synonymous with program evaluation and consists of a plan to evaluate AOTS with regard to assessment of the four critical issues

  6. Acceptance sampling for attributes via hypothesis testing and the hypergeometric distribution

    NASA Astrophysics Data System (ADS)

    Samohyl, Robert Wayne

    2017-10-01

    This paper questions some aspects of attribute acceptance sampling in light of the original concepts of hypothesis testing from Neyman and Pearson (NP). Attribute acceptance sampling in industry, as developed by Dodge and Romig (DR), generally follows the international standards of ISO 2859, and similarly the Brazilian standards NBR 5425 to NBR 5427 and the United States Standards ANSI/ASQC Z1.4. The paper evaluates and extends the area of acceptance sampling in two directions. First, by suggesting the use of the hypergeometric distribution to calculate the parameters of sampling plans avoiding the unnecessary use of approximations such as the binomial or Poisson distributions. We show that, under usual conditions, discrepancies can be large. The conclusion is that the hypergeometric distribution, ubiquitously available in commonly used software, is more appropriate than other distributions for acceptance sampling. Second, and more importantly, we elaborate the theory of acceptance sampling in terms of hypothesis testing rigorously following the original concepts of NP. By offering a common theoretical structure, hypothesis testing from NP can produce a better understanding of applications even beyond the usual areas of industry and commerce such as public health and political polling. With the new procedures, both sample size and sample error can be reduced. What is unclear in traditional acceptance sampling is the necessity of linking the acceptable quality limit (AQL) exclusively to the producer and the lot quality percent defective (LTPD) exclusively to the consumer. In reality, the consumer should also be preoccupied with a value of AQL, as should the producer with LTPD. Furthermore, we can also question why type I error is always uniquely associated with the producer as producer risk, and likewise, the same question arises with consumer risk which is necessarily associated with type II error. The resolution of these questions is new to the literature. The

  7. 46 CFR 164.023-11 - Acceptance tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 6 2014-10-01 2014-10-01 false Acceptance tests. 164.023-11 Section 164.023-11 Shipping...: SPECIFICATIONS AND APPROVAL MATERIALS Thread for Personal Flotation Devices § 164.023-11 Acceptance tests. (a) Performance testing. Manufacturers shall ensure that the performance tests described in § 164.023-7 (a) or (b...

  8. Expanding HIV testing and counselling into communities: Feasibility, acceptability, and effects of an integrated family planning/HTC service delivery model by Village Health Teams in Uganda.

    PubMed

    Brunie, Aurélie; Wamala-Mucheri, Patricia; Akol, Angela; Mercer, Sarah; Chen, Mario

    2016-10-01

    Improving HIV testing and counselling (HTC) requires a range of strategies. This article reports on HTC service delivery by Village Health Teams (VHTs) in Uganda in the context of a model integrating this new component into pre-existing family planning services. Eight health centres from matched pairs were randomly allocated to intervention or control. After being trained, 36 VHTs reporting to selected facilities in the intervention group started offering HTC along with family planning, while VHTs in the control group provided family planning only. Proficiency testing was conducted as external quality assurance. A survey of all 36 VHTs and 137 family planning clients in the intervention group and 119 clients in the control group and a review of record data were conducted after 10 months. Survey responses by VHTs and their clients in the intervention group demonstrate knowledge of counselling messages and safe testing. External quality assessment results provide additional evidence of competency. Eighty per cent of the family planning clients surveyed in the intervention group received an HIV test during the intervention; 27% of those were first-time testers. More clients had ever tested for HIV in the intervention group compared with the control; clients also retested more often. Findings indicate that this model is feasible and acceptable for expanding quality HTC into communities. This study was registered with ClinicalTrials.gov, number [NCT02244398]. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  9. NEVADA TEST SITE WASTE ACCEPTANCE CRITERIA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    U.S. DEPARTMENT OF ENERGY, NATIONAL NUCLEAR SECURITY ADMINISTRATION, NEVADA SITE OFFICE

    This document establishes the U. S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO) waste acceptance criteria (WAC). The WAC provides the requirements, terms, and conditions under which the Nevada Test Site will accept low-level radioactive and mixed waste for disposal. Mixed waste generated within the State of Nevada by NNSA/NSO activities is accepted for disposal. It includes requirements for the generator waste certification program, characterization, traceability, waste form, packaging, and transfer. The criteria apply to radioactive waste received at the Nevada Test Site Area 3 and Area 5 Radioactive Waste Management Site for storage or disposal.

  10. Acceptability of a theory of planned behaviour email-based nutrition intervention.

    PubMed

    Kothe, E J; Mullan, B A

    2014-03-01

    This study investigated feasibility and acceptability of a new email-delivered intervention promoting fruit and vegetable consumption in a university-based population of Australian young adults. The study explored whether there are differences in the reported feasibility and acceptability between demographic groups within the population of interest and at three levels of intervention intensity. The email-delivered intervention program consists of an implementation intention 'planning task' and between 3 and 15 short email messages over a 15-day study period. The intervention program was developed using the Theory of Planned Behaviour and was designed to modify perceived behavioural control. One hundred and ten participants (mean age = 19.21 years, 25.6% male) completed the feasibility and acceptability questionnaire at Day 15. This questionnaire contained items about all intervention components. High acceptability and feasibility scores were found for all intervention parts and at all levels of intervention intensity. There were few significant differences in the reported acceptability of items between key demographic sub-groups, and no differences in reported acceptability at different levels of intervention intensity. These results suggest that this email-delivered intervention is an acceptable and feasible tool for promoting fruit and vegetable consumption for participants in the target population.

  11. Probabilistic Requirements (Partial) Verification Methods Best Practices Improvement. Variables Acceptance Sampling Calculators: Empirical Testing. Volume 2

    NASA Technical Reports Server (NTRS)

    Johnson, Kenneth L.; White, K. Preston, Jr.

    2012-01-01

    The NASA Engineering and Safety Center was requested to improve on the Best Practices document produced for the NESC assessment, Verification of Probabilistic Requirements for the Constellation Program, by giving a recommended procedure for using acceptance sampling by variables techniques as an alternative to the potentially resource-intensive acceptance sampling by attributes method given in the document. In this paper, the results of empirical tests intended to assess the accuracy of acceptance sampling plan calculators implemented for six variable distributions are presented.

  12. L-286 Acceptance Test Record

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    HARMON, B.C.

    2000-01-14

    This document provides a detailed account of how the acceptance testing was conducted for Project L-286, ''200E Area Sanitary Water Plant Effluent Stream Reduction''. The testing of the L-286 instrumentation system was conducted under the direct supervision

  13. Nevada Test Site Waste Acceptance Criteria (NTSWAC)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NNSA /NSO Waste Management Project

    This document establishes the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, Nevada Test Site Waste Acceptance Criteria (NTSWAC). The NTSWAC provides the requirements, terms, and conditions under which the Nevada Test Site will accept low-level radioactive (LLW) and LLW Mixed Waste (MW) for disposal.

  14. Designing a two-rank acceptance sampling plan for quality inspection of geospatial data products

    NASA Astrophysics Data System (ADS)

    Tong, Xiaohua; Wang, Zhenhua; Xie, Huan; Liang, Dan; Jiang, Zuoqin; Li, Jinchao; Li, Jun

    2011-10-01

    To address the disadvantages of classical sampling plans designed for traditional industrial products, we originally propose a two-rank acceptance sampling plan (TRASP) for the inspection of geospatial data outputs based on the acceptance quality level (AQL). The first rank sampling plan is to inspect the lot consisting of map sheets, and the second is to inspect the lot consisting of features in an individual map sheet. The TRASP design is formulated as an optimization problem with respect to sample size and acceptance number, which covers two lot size cases. The first case is for a small lot size with nonconformities being modeled by a hypergeometric distribution function, and the second is for a larger lot size with nonconformities being modeled by a Poisson distribution function. The proposed TRASP is illustrated through two empirical case studies. Our analysis demonstrates that: (1) the proposed TRASP provides a general approach for quality inspection of geospatial data outputs consisting of non-uniform items and (2) the proposed acceptance sampling plan based on TRASP performs better than other classical sampling plans. It overcomes the drawbacks of percent sampling, i.e., "strictness for large lot size, toleration for small lot size," and those of a national standard used specifically for industrial outputs, i.e., "lots with different sizes corresponding to the same sampling plan."

  15. Payload test philosophy. [JPL views on qualification/acceptance testing

    NASA Technical Reports Server (NTRS)

    Gindorf, T.

    1979-01-01

    The general philosophy of how JPL views payload qualification/acceptance testing for programs that are done either in-house or by contractors is described. Particular attention is given to mission risk classifications, preliminary critical design reviews, environmental design requirements, the thermal and dynamics development tests, and the flight spacecraft system test.

  16. Some factors affecting acceptance of family planning in Manus.

    PubMed

    Avue, B; Freeman, P

    1991-12-01

    This paper examines selected factors affecting the acceptance and delivery of modern family planning from health centres in Manus. A survey was carried out of mothers attending Maternal and Child Health clinics and a written questionnaire was given to health workers. The survey of mothers demonstrated the importance of the husband's approval for contraceptive practice and showed that knowledge about traditional methods of family planning is widespread. The health workers' questionnaire demonstrated a high level of dissatisfaction with the current family planning program delivered by health clinics: 45% found the program ineffective; 68% wrote that health workers' attitudes discouraged mothers from attending for family planning. The perceived and actual benefits and costs of children and the role of men should be assessed locally before planning future family planning programs. Widespread retraining and motivating of health workers is essential if improved coverage is to be achieved through health services. The efficacy of alternative methods of delivery of family planning such as local community-based and social marketing programs should also be investigated.

  17. Computer-facilitated rapid HIV testing in emergency care settings: provider and patient usability and acceptability.

    PubMed

    Spielberg, Freya; Kurth, Ann E; Severynen, Anneleen; Hsieh, Yu-Hsiang; Moring-Parris, Daniel; Mackenzie, Sara; Rothman, Richard

    2011-06-01

    Providers in emergency care settings (ECSs) often face barriers to expanded HIV testing. We undertook formative research to understand the potential utility of a computer tool, "CARE," to facilitate rapid HIV testing in ECSs. Computer tool usability and acceptability were assessed among 35 adult patients, and provider focus groups were held, in two ECSs in Washington State and Maryland. The computer tool was usable by patients of varying computer literacy. Patients appreciated the tool's privacy and lack of judgment and their ability to reflect on HIV risks and create risk reduction plans. Staff voiced concerns regarding ECS-based HIV testing generally, including resources for follow-up of newly diagnosed people. Computer-delivered HIV testing support was acceptable and usable among low-literacy populations in two ECSs. Such tools may help circumvent some practical barriers associated with routine HIV testing in busy settings though linkages to care will still be needed.

  18. SigmaPlot 2000, Version 6.00, SPSS Inc. Computer Software Test Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    HURLBUT, S.T.

    2000-10-24

    SigmaPlot is a vendor software product used in conjunction with the supercritical fluid extraction Fourier transform infrared spectrometer (SFE-FTIR) system. This product converts the raw spectral data to useful area numbers. SigmaPlot will be used in conjunction with procedure ZA-565-301, ''Determination of Moisture by Supercritical Fluid Extraction and Infrared Detection.'' This test plan will be performed in conjunction with or prior to HNF-6936, ''HA-53 Supercritical Fluid Extraction System Acceptance Test Plan'', to perform analyses for water. The test will ensure that the software can be installed properly and will manipulate the analytical data correctly.

  19. The Rapid Integration and Test Environment: A Process for Achieving Software Test Acceptance

    DTIC Science & Technology

    2010-05-01

    Test Environment : A Process for Achieving Software Test Acceptance 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S...mlif`v= 365= k^s^i=mlpqdo^ar^qb=p`elli= The Rapid Integration and Test Environment : A Process for Achieving Software Test Acceptance Patrick V...was awarded the Bronze Star. Introduction The Rapid Integration and Test Environment (RITE) initiative, implemented by the Program Executive Office

  20. 105-KE Isolation Barrier Leak Rate Acceptance Test Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCracken, K.J.

    1995-06-14

    This Acceptance Test Report (ATR) contains the completed and signed Acceptance Procedure (ATP) for the 105-KE Isolations Barrier Leak Rate Test. The Test Engineer`s log, the completed sections of the ATP in the Appendix for Repeat Testing (Appendix K), the approved WHC J-7s (Appendix H), the data logger files (Appendices T and U), and the post test calibration checks (Appendix V) are included.

  1. Induction graphitizing furnace acceptance test report

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The induction furnace was designed to provide the controlled temperature and environment required for the post-cure, carbonization and graphitization processes for the fabrication of a fibrous graphite NERVA nozzle extension. The acceptance testing required six tests and a total operating time of 298 hrs. Low temperature mode operations, 120 to 850 C, were completed in one test run. High temperature mode operations, 120 to 2750 C, were completed during five tests.

  2. Acceptance test report, 241-SY-101 Flexible Receiver System, Phase 2 testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ritter, G.A.

    1995-02-06

    This document summarizes the results of the Phase 2 acceptance test of the 241-SY-101 Flexible Receiver System (FRS). The FRS is one of six major components of the Equipment Removal System, which has been designed to retrieve, transport, and store the test mixer pump currently installed in Tank 241-SY-101. The purpose of this acceptance test is to verify the strength of the containment bag and bag bottom cinching mechanism. It is postulated that 68 gallons of waste could be trapped inside the pump internals. The bag must be capable of supporting this waste if it shakes loose and drains tomore » the bottom of the bag after the bag bottom has been cinched closed. This acceptance test was performed at the Maintenance and Storage Facility (MASF) Facility in the 400 area on January 23, 1995. The bag assembly supported the weight of 920 kg (2,020 lbs) of water with no leakage or damage to the bag. This value meets the acceptance criteria of 910 kg of water and therefore the results were found to be acceptable. The maximum volume of liquid expected to be held up in the pump internals is 258 L (68 gallons), which corresponds to 410 kg. This test weight gives just over a safety factor of 2. The bag also supported a small shock load while it was filled with water when the crane hoisted the bag assembly up and down. Based on the strength rating of the bag components, the bag assembly should support 2--3 times the test weight of 910 kg.« less

  3. Effect of testing experience and profession on provider acceptability of rapid HIV testing after implementation in public sexual health clinics in Sydney.

    PubMed

    Conway, D P; Guy, R; McNulty, A; Couldwell, D L; Davies, S C; Smith, D E; Keen, P; Cunningham, P; Holt, M

    2015-05-01

    Rapid HIV testing (RHT) is well established in many countries, but it is new in Australia since a policy change in 2011. We assessed service provider acceptability of RHT before and after its implementation in four Sydney public sexual health clinics. Service providers were surveyed immediately after training in RHT and again 6-12 months later. Differences in mean scores between survey rounds were assessed via t-tests, with stratification by profession and the number of tests performed. RHT was rated as highly acceptable among staff at baseline and acceptability scores improved between survey rounds. Belief in being sufficiently skilled and experienced to perform RHT (P = 0.004) and confidence in the delivery of nonreactive results increased (P = 0.007), while the belief that RHT was disruptive declined (P = 0.001). Acceptability was higher for staff who had performed a greater number of tests regarding comfort with their role in RHT (P = 0.004) and belief that patients were satisfied with RHT (P = 0.007). Compared with nurses, doctors had a stronger preference for a faster rapid test (P = 0.027) and were more likely to agree that RHT interfered with consultations (P = 0.014). Differences in responses between professions may reflect differences in staff roles, the type of patients seen by staff and the model of testing used, all of which may affect the number of tests performed by staff. These findings may inform planning for how best to implement RHT in clinical services. © 2015 British HIV Association.

  4. Empirical Testing of a Theoretical Extension of the Technology Acceptance Model: An Exploratory Study of Educational Wikis

    ERIC Educational Resources Information Center

    Liu, Xun

    2010-01-01

    This study extended the technology acceptance model and empirically tested the new model with wikis, a new type of educational technology. Based on social cognitive theory and the theory of planned behavior, three new variables, wiki self-efficacy, online posting anxiety, and perceived behavioral control, were added to the original technology…

  5. Biodiesel Test Plan

    DTIC Science & Technology

    2014-07-01

    Biodiesel Test Plan Distribution Statement A: Approved for Public Release; distribution is unlimited. July 2014 Report No. CG-D-07-14...Appendix C) Biodiesel Test Plan ii UNCLAS//Public | CG-926 R&DC | G. W. Johnson, et al. Public | July 2014 N O T I C E This...Development Center 1 Chelsea Street New London, CT 06320 Biodiesel Test Plan iii UNCLAS//Public | CG-926 R&DC | G. W. Johnson, et al

  6. Project W-314 specific test and evaluation plan for transfer line SN-633 (241-AX-B to 241-AY-02A)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hays, W.H.

    1998-03-20

    The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made by the addition of the SN-633 transfer line by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation Plan (TEP). This STEP encompasses all testing activities required to demonstrate compliance to the project design criteria as it relates to the addition of transfer line SN-633. The Project Design Specificationsmore » (PDS) identify the specific testing activities required for the Project. Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities), Factory Acceptance Tests (FATs), installation tests and inspections, Construction Acceptance Tests (CATs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), and Operational Test Procedures (OTPs). It should be noted that POTPs are not required for testing of the transfer line addition. The STEP will be utilized in conjunction with the TEP for verification and validation.« less

  7. SU-E-T-60: A Plan Quality Index in IMRT QA That Is Independent of the Acceptance Criteria

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, D; Kang, S; Kim, T

    2015-06-15

    Purpose: In IMRT QA, plan quality evaluation is made based on pass rate under preset acceptance criteria, mostly using gamma-values. This method is convenient but, its Result highly depends on what the acceptance criteria are and suffers from the lack of sensitivity in judging how good the plan is. In this study, we introduced a simple but effective plan quality index of IMRT QA based on dose difference only to supplement such shortcomings, and investigated its validity. Methods: The proposed index is a single value which is calculated mainly based on point-by-point comparison between planned and measured dose distributions, andmore » it becomes “1” in an ideal case. A systematic evaluation was performed with one-dimensional test dose distributions. For 3 hypothetical dose profiles, various displacements (in both dose and space) were introduced, the proposed index was calculated for each case, and the behavior of obtained indices was analyzed and compared with that of gamma evaluation. In addition, the feasibility of the index was assessed with clinical IMRT/VMAT/SBRT QA cases for different sites (prostate, head & neck, liver, lung, spine, and abdomen). Results: The proposed index showed more robust correlation with the amount of induced displacement compared to the gamma evaluation method. No matter what the acceptance criteria are (e.g., whether 3%/3mm or 2%/2mm), it was possible to clearly rank every case with the proposed index while it was difficult to do with the gamma evaluation method. Conclusion: IMRT plan quality can be evaluated quantitatively by the proposed index. It is considered that the proposed index would provide useful information for better judging the level of goodness of each plan and its Result is independent of the acceptance criteria. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded

  8. Nevada Test Site Waste Acceptance Criteria

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    U. S. Department of Energy, National Nuclear Security Administration Nevada Site Office

    This document establishes the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) waste acceptance criteria (WAC). The WAC provides the requirements, terms, and conditions under which the Nevada Test Site (NTS) will accept low-level radioactive (LLW) and mixed waste (MW) for disposal. It includes requirements for the generator waste certification program, characterization, traceability, waste form, packaging, and transfer. The criteria apply to radioactive waste received at the NTS Area 3 and Area 5 Radioactive Waste Management Complex (RWMC) for storage or disposal.

  9. Proposed acceptance, qualification, and characterization tests for thin-film PV modules

    NASA Technical Reports Server (NTRS)

    Waddington, D.; Mrig, L.; Deblasio, R.; Ross, R.

    1988-01-01

    Details of a proposed test program for PV thin-film modules which the Department of Energy has directed the Solar Energy Research Institute (SERI) to prepare are presented. Results of one of the characterization tests that SERI has performed are also presented. The objective is to establish a common approach to testing modules that will be acceptable to both users and manufacturers. The tests include acceptance, qualification, and characterization tests. Acceptance tests verify that randomly selected modules have similar characteristics. Qualification tests are based on accelerated test methods designed to simulate adverse conditions. Characterization tests provide data on performance in a predefined environment.

  10. Decision Models for Determining the Optimal Life Test Sampling Plans

    NASA Astrophysics Data System (ADS)

    Nechval, Nicholas A.; Nechval, Konstantin N.; Purgailis, Maris; Berzins, Gundars; Strelchonok, Vladimir F.

    2010-11-01

    Life test sampling plan is a technique, which consists of sampling, inspection, and decision making in determining the acceptance or rejection of a batch of products by experiments for examining the continuous usage time of the products. In life testing studies, the lifetime is usually assumed to be distributed as either a one-parameter exponential distribution, or a two-parameter Weibull distribution with the assumption that the shape parameter is known. Such oversimplified assumptions can facilitate the follow-up analyses, but may overlook the fact that the lifetime distribution can significantly affect the estimation of the failure rate of a product. Moreover, sampling costs, inspection costs, warranty costs, and rejection costs are all essential, and ought to be considered in choosing an appropriate sampling plan. The choice of an appropriate life test sampling plan is a crucial decision problem because a good plan not only can help producers save testing time, and reduce testing cost; but it also can positively affect the image of the product, and thus attract more consumers to buy it. This paper develops the frequentist (non-Bayesian) decision models for determining the optimal life test sampling plans with an aim of cost minimization by identifying the appropriate number of product failures in a sample that should be used as a threshold in judging the rejection of a batch. The two-parameter exponential and Weibull distributions with two unknown parameters are assumed to be appropriate for modelling the lifetime of a product. A practical numerical application is employed to demonstrate the proposed approach.

  11. Limits of acceptable change planning in the Selway-Bitterroot Wilderness: 1985 to 1997 (FIDL)

    Treesearch

    Dan Ritter

    1997-01-01

    In 1985 the Forest Supervisors and staff of the Bitterroot, Clearwater, and Nez Perce National Forests met and agreed to an action plan for implementing a Limits of Acceptable Change (LAC) planning process for the Selway-Bitterroot Wilderness (SBW). The process, which was to include a citizens task force, was to produce a completed management plan in 2 years. Eight...

  12. Evaluation of acceptance strength tests for concrete pavements.

    DOT National Transportation Integrated Search

    2005-06-30

    The North Carolina Department of Transportation has used traditionally flexural strength tests for acceptance : testing of Portland cement concrete pavements. This report summarizes a research project implemented to : investigate the feasibility of u...

  13. Face Validity of Test and Acceptance of Generalized Personality Interpretations

    ERIC Educational Resources Information Center

    Delprato, Dennis J.

    1975-01-01

    The degree to which variations in the face validity of psychological tests affected students' willingness to accept personality interpretations was studied. Acceptance of personality interpretations was compared for four types of tests which varied in face validity. The relationship between judged accuracy and rated likability of the…

  14. 46 CFR 50.25-10 - Acceptance of piping components by specific letter or approved plan.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) MARINE ENGINEERING GENERAL PROVISIONS Acceptance of Material and Piping Components § 50.25-10 Acceptance... approved plan must do the following: (1) Submit an engineering type catalog or representative drawings of... specifications by comparing details of the materials' chemical composition, mechanical properties, method of...

  15. 46 CFR 50.25-10 - Acceptance of piping components by specific letter or approved plan.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) MARINE ENGINEERING GENERAL PROVISIONS Acceptance of Material and Piping Components § 50.25-10 Acceptance... approved plan must do the following: (1) Submit an engineering type catalog or representative drawings of... specifications by comparing details of the materials' chemical composition, mechanical properties, method of...

  16. 46 CFR 50.25-10 - Acceptance of piping components by specific letter or approved plan.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) MARINE ENGINEERING GENERAL PROVISIONS Acceptance of Material and Piping Components § 50.25-10 Acceptance... approved plan must do the following: (1) Submit an engineering type catalog or representative drawings of... specifications by comparing details of the materials' chemical composition, mechanical properties, method of...

  17. 46 CFR 50.25-10 - Acceptance of piping components by specific letter or approved plan.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) MARINE ENGINEERING GENERAL PROVISIONS Acceptance of Material and Piping Components § 50.25-10 Acceptance... approved plan must do the following: (1) Submit an engineering type catalog or representative drawings of... specifications by comparing details of the materials' chemical composition, mechanical properties, method of...

  18. 46 CFR 50.25-10 - Acceptance of piping components by specific letter or approved plan.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) MARINE ENGINEERING GENERAL PROVISIONS Acceptance of Material and Piping Components § 50.25-10 Acceptance... approved plan must do the following: (1) Submit an engineering type catalog or representative drawings of... specifications by comparing details of the materials' chemical composition, mechanical properties, method of...

  19. Cassini RTG acceptance test results and RTG performance on Galileo and Ulysses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly, C.E.; Klee, P.M.

    Flight acceptance testing has been completed for the RTGs to be used on the Cassini spacecraft which is scheduled for an October 6, 1997 launch to Saturn. The acceptance test program includes vibration tests, magnetic field measurements, mass properties (weight and c.g.) and thermal vacuum test. This paper presents the thermal vacuum test results. Three RTGs are to be used, F-2, F-6, and F-7. F-5 is the backup RTG, as it was for the Galileo and Ulysses missions launched in 1989 and 1990, respectively. RTG performance measured during the thermal vacuum tests carried out at the Mound Laboratory facility metmore » all specification requirements. Beginning of mission (BOM) and end of mission (EOM) power predictions have been made based on these tests results. BOM power is predicted to be 888 watts compared to the minimum requirement of 826 watts. Degradation models predict the EOM power after 16 years is to be 640 watts compared to a minimum requirement of 596 watts. Results of small scale module tests are also shown. The modules contain couples from the qualification and flight production runs. The tests have exceeded 28,000 hours (3.2 years) and are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. All test results indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of over 5% are predicted. Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Telemetry data are also shown for the RTG on the Ulysses spacecraft which completed its planned mission in 1995 and is now in the extended mission.« less

  20. Cassini RTG acceptance test results and RTG performance on Galileo and Ulysses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly, C.E.; Klee, P.M.

    Flight acceptance testing has been completed for the RTGs to be used on the Cassini spacecraft which is scheduled for an October 6, 1997 launch to Saturn. The acceptance test program includes vibration tests, magnetic field measurements, properties (weight and c.g.) and thermal vacuum test. This paper presents The thermal vacuum test results. Three RTGs are to be used, F-2, F-6, and F-7. F-5 is tile back-up RTG, as it was for the Galileo and Ulysses missions launched in 1989 and 1990, respectively. RTG performance measured during the thermal vacuum tests carried out at die Mound Laboratory facility met allmore » specification requirements. Beginning of mission (BOM) and end of mission (EOM) power predictions have been made based on than tests results. BOM power is predicted to be 888 watts compared to the minimum requirement of 826 watts. Degradation models predict the EOM power after 16 years is to be 640 watts compared to a minimum requirement of 596 watts. Results of small scale module tests are also showing. The modules contain couples from the qualification and flight production runs. The tests have exceeded 28,000 hours (3.2 years) and are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. All test results indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of over five percent are predicted. Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Telemetry data are also shown for the RTG on the Ulysses spacecraft which completed its planned mission in 1995 and is now in the extended mission.« less

  1. Cassini RTG Acceptance Test Results and RTG Performance on Galileo and Ulysses

    DOE R&D Accomplishments Database

    Kelly, C. E.; Klee, P. M.

    1997-06-01

    Flight acceptance testing has been completed for the RTGs to be used on the Cassini spacecraft which is scheduled for an October 6, 1997 launch to Saturn. The acceptance test program includes vibration tests, magnetic field measurements, properties (weight and c.g.) and thermal vacuum test. This paper presents The thermal vacuum test results. Three RTGs are to be used, F 2, F 6, and F 7. F 5 is tile back up RTG, as it was for the Galileo and Ulysses missions launched in 1989 and 1990, respectively. RTG performance measured during the thermal vacuum tests carried out at die Mound Laboratory facility met all specification requirements. Beginning of mission (BOM) and end of mission (EOM) power predictions have been made based on than tests results. BOM power is predicted to be 888 watts compared to the minimum requirement of 826 watts. Degradation models predict the EOM power after 16 years is to be 640 watts compared to a minimum requirement of 596 watts. Results of small scale module tests are also showing. The modules contain couples from the qualification and flight production runs. The tests have exceeded 28,000 hours (3.2 years) and are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. All test results indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of over five percent are predicted. Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Telemetry data are also shown for the RTG on the Ulysses spacecraft which completed its planned mission in 1995 and is now in the extended mission.

  2. How to pass a sensor acceptance test: using the gap between acceptance criteria and operational performance

    NASA Astrophysics Data System (ADS)

    Bijl, Piet

    2016-10-01

    When acquiring a new imaging system and operational task performance is a critical factor for success, it is necessary to specify minimum acceptance requirements that need to be met using a sensor performance model and/or performance tests. Currently, there exist a variety of models and test from different origin (defense, security, road safety, optometry) and they all do different predictions. This study reviews a number of frequently used methods and shows the effects that small changes in procedure or threshold criteria can have on the outcome of a test. For example, a system may meet the acceptance requirements but not satisfy the needs for the operational task, or the choice of test may determine the rank order of candidate sensors. The goal of the paper is to make people aware of the pitfalls associated with the acquisition process, by i) illustrating potential tricks to have a system accepted that is actually not suited for the operational task, and ii) providing tips to avoid this unwanted situation.

  3. Project W-314 specific test and evaluation plan for AZ tank farm upgrades

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hays, W.H.

    1998-08-12

    The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made by the addition of the SN-631 transfer line from the AZ-O1A pit to the AZ-02A pit by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation P1 an (TEP). Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities, etc), Factory Tests and Inspections (FTIs), installation tests andmore » inspections, Construction Tests and Inspections (CTIs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), and Operational Test Procedures (OTPs). The STEP will be utilized in conjunction with the TEP for verification and validation.« less

  4. Acceptability of HIV self-testing: a systematic literature review.

    PubMed

    Krause, Janne; Subklew-Sehume, Friederike; Kenyon, Chris; Colebunders, Robert

    2013-08-08

    The uptake of HIV testing and counselling services remains low in risk groups around the world. Fear of stigmatisation, discrimination and breach of confidentiality results in low service usage among risk groups. HIV self-testing (HST) is a confidential HIV testing option that enables people to find out their status in the privacy of their homes. We evaluated the acceptability of HST and the benefits and challenges linked to the introduction of HST. A literature review was conducted on the acceptability of HST in projects in which HST was offered to study participants. Besides acceptability rates of HST, accuracy rates of self-testing, referral rates of HIV-positive individuals into medical care, disclosure rates and rates of first-time testers were assessed. In addition, the utilisation rate of a telephone hotline for counselling issues and clients` attitudes towards HST were extracted. Eleven studies met the inclusion criteria (HST had been offered effectively to study participants and had been administered by participants themselves) and demonstrated universally high acceptability of HST among study populations. Studies included populations from resource poor settings (Kenya and Malawi) and from high-income countries (USA, Spain and Singapore). The majority of study participants were able to perform HST accurately with no or little support from trained staff. Participants appreciated the confidentiality and privacy but felt that the provision of adequate counselling services was inadequate. The review demonstrates that HST is an acceptable testing alternative for risk groups and can be performed accurately by the majority of self-testers. Clients especially value the privacy and confidentiality of HST. Linkage to counselling as well as to treatment and care services remain major challenges.

  5. Alphabus Mechanical Validation Plan and Test Campaign

    NASA Astrophysics Data System (ADS)

    Calvisi, G.; Bonnet, D.; Belliol, P.; Lodereau, P.; Redoundo, R.

    2012-07-01

    A joint team of the two leading European satellite companies (Astrium and Thales Alenia Space) worked with the support of ESA and CNES to define a product line able to efficiently address the upper segment of communications satellites : Alphabus Starting in 2009 and up to 2011 the mechanical validation of the Alphabus platform has been obtained thanks to static tests performed on dedicated static model and to environmental test performed on the first satellite based on Alphabus: Alphasat I-XL. The mechanical validation of the Alphabus platform presented an excellent opportunity to improve the validation and qualification process, with respect to static, sine vibrations, acoustic and L/V shock environment, minimizing recurrent cost of manufacturing, integration and testing. A main driver on mechanical testing is that mechanical acceptance testing at satellite level will be performed with empty tanks due to technical constraints (limitation of existing vibration devices) and programmatic advantages (test risk reduction, test schedule minimization). In this paper the impacts that such testing logic have on validation plan are briefly recalled and its actual application for Alphasat PFM mechanical test campaign is detailed.

  6. Solar Dynamics Observatory On-Orbit Jitter Testing, Analysis, and Mitigation Plans

    NASA Technical Reports Server (NTRS)

    Liu, Kuo-Chia (Alice); Blaurock, Carl A.; Bourkland, Kristin L.; Morgenstern, Wendy M.; Maghami, Peiman G.

    2011-01-01

    -orbit jitter tests were designed to satisfy the following four objectives: 1. Determine the acceptable reaction wheel operational speed range during Science Mode. 2. Determine HGA algorithm jitter parameters (number of stagger steps and enable/disable no-steprequests). 3. Determine acceptable EVE instrument filter wheels spin rates. 4. Determine if AIA instrument filter wheels excite the first AIA telescope structural mode. This paper provides detailed information on the SDO wheel jitter test plan, shows on-orbit jitter measurements and how ground predictions compare to those measurements, and describes the final jitter mitigation plan executed on SDO.

  7. Hereditary hemochromatosis: awareness and genetic testing acceptability in Western Romania.

    PubMed

    Neghina, Adriana Maria; Anghel, Andrei

    2010-12-01

    a public health strategy to promote early diagnosis of hemochromatosis gene (HFE)-related hemochromatosis (HFE-HH) largely depends on people's acceptance of available screening tests. The present study aimed at evaluating patient awareness of HFE-HH and their acceptance of DNA testing in western Romania. a total of 221 participants were randomly recruited from the ambulatory unit of the Emergency County Hospital in Timisoara, Romania. They received brief information on HFE-HH and were assessed for the signs and symptoms of hemochromatosis. HFE genotyping was offered to all of them. Only two cases (0.9%) had previous knowledge of HFE-HH. Twenty-one cases (9.5%) underwent genetic testing. Characteristics associated with test acceptance were age <45 years, male gender, and educational attainment. Acceptance was associated with a desire to know if they had HFE-HH (85.7%). The most prevalent refusal reason was a desire for more information (41%). larger educational programs are required to increase people's awareness about HFE-HH in western Romania. Nevertheless, within health care settings, the importance of disease detection and patient's educational background appear to be essential for achieving high rates of participation in the genetic test.

  8. Service User- and Carer-Reported Measures of Involvement in Mental Health Care Planning: Methodological Quality and Acceptability to Users

    PubMed Central

    Gibbons, Chris J.; Bee, Penny E.; Walker, Lauren; Price, Owen; Lovell, Karina

    2014-01-01

    Background: Increasing service user and carer involvement in mental health care planning is a key healthcare priority but one that is difficult to achieve in practice. To better understand and measure user and carer involvement, it is crucial to have measurement questionnaires that are both psychometrically robust and acceptable to the end user. Methods: We conducted a systematic review using the terms “care plan$,” “mental health,” “user perspective$,” and “user participation” and their linguistic variants as search terms. Databases were searched from inception to November 2012, with an update search at the end of September 2014. We included any articles that described the development, validation or use of a user and/or carer-reported outcome measures of involvement in mental health care planning. We assessed the psychometric quality of each instrument using the “Evaluating the Measurement of Patient-Reported Outcomes” (EMPRO) criteria. Acceptability of each instrument was assessed using novel criteria developed in consultation with a mental health service user and carer consultation group. Results: We identified eleven papers describing the use, development, and/or validation of nine user/carer-reported outcome measures. Psychometric properties were sparsely reported and the questionnaires met few service user/carer-nominated attributes for acceptability. Where reported, basic psychometric statistics were of good quality, indicating that some measures may perform well if subjected to more rigorous psychometric tests. The majority were deemed to be too long for use in practice. Discussion: Multiple instruments are available to measure user/carer involvement in mental health care planning but are either of poor quality or poorly described. Existing measures cannot be considered psychometrically robust by modern standards, and cannot currently be recommended for use. Our review has identified an important knowledge gap, and an urgent need to

  9. Influence of gender of the teaching staff on students' acceptance of a virtual implant planning course.

    PubMed

    Nkenke, Emeka; Vairaktaris, Elefterios; Schaller, Hans-Günter; Perisanidis, Christos; Eitner, Stephan

    2017-05-01

    Acceptance of new technology is influenced by a number of situational and social factors. So far, only limited data are available on the influence of the teaching staff's gender on the acceptance of virtual dental implant planning by students. This study aimed at assessing the influence of the teaching staff's gender on the acceptance of a virtual implant planning course by male and female undergraduate dental students and their general attitude toward implantology. Two groups of third-year dental students (group 1, 9 males, 22 females; group 2, 12 males, 20 females) attended a virtual dental implant planning course. For the first group the teaching staff was all-male, while the teaching staff was all-female for the second group. After completion of the course the students filled in a technology acceptance questionnaire. An all-female teaching staff led to a degree of technology acceptance that did not differ significantly for male and female students. When the teaching staff was all-male, significant differences for technology acceptance occurred between male and female students. However, male as well as female students attributed the practice of implantology to both genders of dentists, equally, without statistically significant difference independent of the gender of the teaching staff. The more evenly distributed degree of technology acceptance of students of both genders being taught by a female staff is a favorable effect which may be explained by the more egalitarian style of women. Therefore, while feminization in dentistry proceeds, adequate measures should be taken to increase the number of female teachers. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  10. 77 FR 51880 - Requirements for Maintenance of Inspections, Tests, Analyses, and Acceptance Criteria

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-28

    ... Maintenance of Inspections, Tests, Analyses, and Acceptance Criteria AGENCY: Nuclear Regulatory Commission... construction activities through inspections, tests, analyses, and acceptance criteria (ITAAC) under a combined... inspections, tests, or analyses were performed as required, or that acceptance criteria are met, and to notify...

  11. Toward optimizing patient-specific IMRT QA techniques in the accurate detection of dosimetrically acceptable and unacceptable patient plans

    PubMed Central

    McKenzie, Elizabeth M.; Balter, Peter A.; Stingo, Francesco C.; Jones, Jimmy; Followill, David S.; Kry, Stephen F.

    2014-01-01

    Purpose: The authors investigated the performance of several patient-specific intensity-modulated radiation therapy (IMRT) quality assurance (QA) dosimeters in terms of their ability to correctly identify dosimetrically acceptable and unacceptable IMRT patient plans, as determined by an in-house-designed multiple ion chamber phantom used as the gold standard. A further goal was to examine optimal threshold criteria that were consistent and based on the same criteria among the various dosimeters. Methods: The authors used receiver operating characteristic (ROC) curves to determine the sensitivity and specificity of (1) a 2D diode array undergoing anterior irradiation with field-by-field evaluation, (2) a 2D diode array undergoing anterior irradiation with composite evaluation, (3) a 2D diode array using planned irradiation angles with composite evaluation, (4) a helical diode array, (5) radiographic film, and (6) an ion chamber. This was done with a variety of evaluation criteria for a set of 15 dosimetrically unacceptable and 9 acceptable clinical IMRT patient plans, where acceptability was defined on the basis of multiple ion chamber measurements using independent ion chambers and a phantom. The area under the curve (AUC) on the ROC curves was used to compare dosimeter performance across all thresholds. Optimal threshold values were obtained from the ROC curves while incorporating considerations for cost and prevalence of unacceptable plans. Results: Using common clinical acceptance thresholds, most devices performed very poorly in terms of identifying unacceptable plans. Grouping the detector performance based on AUC showed two significantly different groups. The ion chamber, radiographic film, helical diode array, and anterior-delivered composite 2D diode array were in the better-performing group, whereas the anterior-delivered field-by-field and planned gantry angle delivery using the 2D diode array performed less well. Additionally, based on the AUCs, there

  12. Toward optimizing patient-specific IMRT QA techniques in the accurate detection of dosimetrically acceptable and unacceptable patient plans.

    PubMed

    McKenzie, Elizabeth M; Balter, Peter A; Stingo, Francesco C; Jones, Jimmy; Followill, David S; Kry, Stephen F

    2014-12-01

    The authors investigated the performance of several patient-specific intensity-modulated radiation therapy (IMRT) quality assurance (QA) dosimeters in terms of their ability to correctly identify dosimetrically acceptable and unacceptable IMRT patient plans, as determined by an in-house-designed multiple ion chamber phantom used as the gold standard. A further goal was to examine optimal threshold criteria that were consistent and based on the same criteria among the various dosimeters. The authors used receiver operating characteristic (ROC) curves to determine the sensitivity and specificity of (1) a 2D diode array undergoing anterior irradiation with field-by-field evaluation, (2) a 2D diode array undergoing anterior irradiation with composite evaluation, (3) a 2D diode array using planned irradiation angles with composite evaluation, (4) a helical diode array, (5) radiographic film, and (6) an ion chamber. This was done with a variety of evaluation criteria for a set of 15 dosimetrically unacceptable and 9 acceptable clinical IMRT patient plans, where acceptability was defined on the basis of multiple ion chamber measurements using independent ion chambers and a phantom. The area under the curve (AUC) on the ROC curves was used to compare dosimeter performance across all thresholds. Optimal threshold values were obtained from the ROC curves while incorporating considerations for cost and prevalence of unacceptable plans. Using common clinical acceptance thresholds, most devices performed very poorly in terms of identifying unacceptable plans. Grouping the detector performance based on AUC showed two significantly different groups. The ion chamber, radiographic film, helical diode array, and anterior-delivered composite 2D diode array were in the better-performing group, whereas the anterior-delivered field-by-field and planned gantry angle delivery using the 2D diode array performed less well. Additionally, based on the AUCs, there was no significant difference

  13. Shuttle payload vibroacoustic test plan evaluation

    NASA Technical Reports Server (NTRS)

    Stahle, C. V.; Gongloff, H. R.; Young, J. P.; Keegan, W. B.

    1977-01-01

    Statistical decision theory is used to evaluate seven alternate vibro-acoustic test plans for Space Shuttle payloads; test plans include component, subassembly and payload testing and combinations of component and assembly testing. The optimum test levels and the expected cost are determined for each test plan. By including all of the direct cost associated with each test plan and the probabilistic costs due to ground test and flight failures, the test plans which minimize project cost are determined. The lowest cost approach eliminates component testing and maintains flight vibration reliability by performing subassembly tests at a relatively high acoustic level.

  14. ISOLOK VALVE ACCEPTANCE TESTING FOR DWPF SME SAMPLING PROCESS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwards, T.; Hera, K.; Coleman, C.

    2011-12-05

    Evaluation of the Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) cycle time identified several opportunities to improve the CPC processing time. Of the opportunities, a focus area related to optimizing the equipment and efficiency of the sample turnaround time for DWPF Analytical Laboratory was identified. The Mechanical Systems & Custom Equipment Development (MS&CED) Section of the Savannah River National Laboratory (SRNL) evaluated the possibility of using an Isolok{reg_sign} sampling valve as an alternative to the Hydragard{reg_sign} valve for taking process samples. Previous viability testing was conducted with favorable results using the Isolok sampler and reported in SRNL-STI-2010-00749 (1).more » This task has the potential to improve operability, reduce maintenance time and decrease CPC cycle time. This report summarizes the results from acceptance testing which was requested in Task Technical Request (TTR) HLW-DWPF-TTR-2010-0036 (2) and which was conducted as outlined in Task Technical and Quality Assurance Plan (TTQAP) SRNL-RP-2011-00145 (3). The Isolok to be tested is the same model which was tested, qualified, and installed in the Sludge Receipt Adjustment Tank (SRAT) sample system. RW-0333P QA requirements apply to this task. This task was to qualify the Isolok sampler for use in the DWPF Slurry Mix Evaporator (SME) sampling process. The Hydragard, which is the current baseline sampling method, was used for comparison to the Isolok sampling data. The Isolok sampler is an air powered grab sampler used to 'pull' a sample volume from a process line. The operation of the sampler is shown in Figure 1. The image on the left shows the Isolok's spool extended into the process line and the image on the right shows the sampler retracted and then dispensing the liquid into the sampling container. To determine tank homogeneity, a Coliwasa sampler was used to grab samples at a high and low location within the mixing tank. Data from the two

  15. Understanding patient acceptance and refusal of HIV testing in the emergency department

    PubMed Central

    2012-01-01

    Background Despite high rates of patient satisfaction with emergency department (ED) HIV testing, acceptance varies widely. It is thought that patients who decline may be at higher risk for HIV infection, thus we sought to better understand patient acceptance and refusal of ED HIV testing. Methods In-depth interviews with fifty ED patients (28 accepters and 22 decliners of HIV testing) in three ED HIV testing programs that serve vulnerable urban populations in northern California. Results Many factors influenced the decision to accept ED HIV testing, including curiosity, reassurance of negative status, convenience, and opportunity. Similarly, a number of factors influenced the decision to decline HIV testing, including having been tested recently, the perception of being at low risk for HIV infection due to monogamy, abstinence or condom use, and wanting to focus on the medical reason for the ED visit. Both accepters and decliners viewed ED HIV testing favorably and nearly all participants felt comfortable with the testing experience, including the absence of counseling. While many participants who declined an ED HIV test had logical reasons, some participants also made clear that they would prefer not to know their HIV status rather than face psychosocial consequences such as loss of trust in a relationship or disclosure of status in hospital or public health records. Conclusions Testing for HIV in the ED as for any other health problem reduces barriers to testing for some but not all patients. Patients who decline ED HIV testing may have rational reasons, but there are some patients who avoid HIV testing because of psychosocial ramifications. While ED HIV testing is generally acceptable, more targeted approaches to testing are necessary for this subgroup. PMID:22214543

  16. Understanding patient acceptance and refusal of HIV testing in the emergency department.

    PubMed

    Christopoulos, Katerina A; Weiser, Sheri D; Koester, Kimberly A; Myers, Janet J; White, Douglas A E; Kaplan, Beth; Morin, Stephen F

    2012-01-03

    Despite high rates of patient satisfaction with emergency department (ED) HIV testing, acceptance varies widely. It is thought that patients who decline may be at higher risk for HIV infection, thus we sought to better understand patient acceptance and refusal of ED HIV testing. In-depth interviews with fifty ED patients (28 accepters and 22 decliners of HIV testing) in three ED HIV testing programs that serve vulnerable urban populations in northern California. Many factors influenced the decision to accept ED HIV testing, including curiosity, reassurance of negative status, convenience, and opportunity. Similarly, a number of factors influenced the decision to decline HIV testing, including having been tested recently, the perception of being at low risk for HIV infection due to monogamy, abstinence or condom use, and wanting to focus on the medical reason for the ED visit. Both accepters and decliners viewed ED HIV testing favorably and nearly all participants felt comfortable with the testing experience, including the absence of counseling. While many participants who declined an ED HIV test had logical reasons, some participants also made clear that they would prefer not to know their HIV status rather than face psychosocial consequences such as loss of trust in a relationship or disclosure of status in hospital or public health records. Testing for HIV in the ED as for any other health problem reduces barriers to testing for some but not all patients. Patients who decline ED HIV testing may have rational reasons, but there are some patients who avoid HIV testing because of psychosocial ramifications. While ED HIV testing is generally acceptable, more targeted approaches to testing are necessary for this subgroup. © 2012 Christopoulos et al; licensee BioMed Central Ltd.

  17. Automatically generated acceptance test: A software reliability experiment

    NASA Technical Reports Server (NTRS)

    Protzel, Peter W.

    1988-01-01

    This study presents results of a software reliability experiment investigating the feasibility of a new error detection method. The method can be used as an acceptance test and is solely based on empirical data about the behavior of internal states of a program. The experimental design uses the existing environment of a multi-version experiment previously conducted at the NASA Langley Research Center, in which the launch interceptor problem is used as a model. This allows the controlled experimental investigation of versions with well-known single and multiple faults, and the availability of an oracle permits the determination of the error detection performance of the test. Fault interaction phenomena are observed that have an amplifying effect on the number of error occurrences. Preliminary results indicate that all faults examined so far are detected by the acceptance test. This shows promise for further investigations, and for the employment of this test method on other applications.

  18. 46 CFR 164.013-5 - Acceptance tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Acceptance tests. 164.013-5 Section 164.013-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL MATERIALS Foam, Unicellular Polyethylene (Buoyant, Slab, Slitted Trigonal Pattern...

  19. 46 CFR 164.013-5 - Acceptance tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Acceptance tests. 164.013-5 Section 164.013-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL MATERIALS Foam, Unicellular Polyethylene (Buoyant, Slab, Slitted Trigonal Pattern...

  20. Perceived Use and Acceptance of Cloud Enterprise Resource Planning (ERP) Implementation in the Manufacturing Industries

    ERIC Educational Resources Information Center

    Adeboje, Adewale

    2015-01-01

    The purpose of this study was to gain an insight into perceived use and acceptance for implementing an enterprise resource planning system and the decision whether to contract out the enterprise resource planning (ERP) service to a cloud provider. Cloud-based ERP systems can provide many advantages to the normal implementation of the same systems…

  1. Fatigue acceptance test limit criterion for larger diameter rolled thread fasteners

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kephart, A.R.

    1997-05-01

    This document describes a fatigue lifetime acceptance test criterion by which studs having rolled threads, larger than 1.0 inches in diameter, can be assured to meet minimum quality attributes associated with a controlled rolling process. This criterion is derived from a stress dependent, room temperature air fatigue database for test studs having a 0.625 inch diameter threads of Alloys X-750 HTH and direct aged 625. Anticipated fatigue lives of larger threads are based on thread root elastic stress concentration factors which increase with increasing thread diameters. Over the thread size range of interest, a 30% increase in notch stress ismore » equivalent to a factor of five (5X) reduction in fatigue life. The resulting diameter dependent fatigue acceptance criterion is normalized to the aerospace rolled thread acceptance standards for a 1.0 inch diameter, 0.125 inch pitch, Unified National thread with a controlled Root radius (UNR). Testing was conducted at a stress of 50% of the minimum specified material ultimate strength, 80 Ksi, and at a stress ratio (R) of 0.10. Limited test data for fastener diameters of 1.00 to 2.25 inches are compared to the acceptance criterion. Sensitivity of fatigue life of threads to test nut geometry variables was also shown to be dependent on notch stress conditions. Bearing surface concavity of the compression nuts and thread flank contact mismatch conditions can significantly affect the fastener fatigue life. Without improved controls these conditions could potentially provide misleading acceptance data. Alternate test nut geometry features are described and implemented in the rolled thread stud specification, MIL-DTL-24789(SH), to mitigate the potential effects on fatigue acceptance data.« less

  2. For your interest? The ethical acceptability of using non-invasive prenatal testing to test 'purely for information'.

    PubMed

    Deans, Zuzana; Clarke, Angus J; Newson, Ainsley J

    2015-01-01

    Non-invasive prenatal testing (NIPT) is an emerging form of prenatal genetic testing that provides information about the genetic constitution of a foetus without the risk of pregnancy loss as a direct result of the test procedure. As with other prenatal tests, information from NIPT can help to make a decision about termination of pregnancy, plan contingencies for birth or prepare parents to raise a child with a genetic condition. NIPT can also be used by women and couples to test purely 'for information'. Here, no particular action is envisaged following the test; it is motivated entirely by an interest in the result. The fact that NIPT can be performed without posing a risk to the pregnancy could give rise to an increase in such requests. In this paper, we examine the ethical aspects of using NIPT 'purely for information', including the competing interests of the prospective parents and the future child, and the acceptability of testing for 'frivolous' reasons. Drawing on several clinical scenarios, we claim that arguments about testing children for genetic conditions are relevant to this debate. In addition, we raise ethical concerns over the potential for objectification of the child. We conclude that, in most cases, using NIPT to test for adult-onset conditions, carrier status or non-serious traits presenting in childhood would be unacceptable. © 2014 John Wiley & Sons Ltd.

  3. 42 CFR 484.18 - Condition of participation: Acceptance of patients, plan of care, and medical supervision.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., and medical supervision. Patients are accepted for treatment on the basis of a reasonable expectation... a doctor of medicine, osteopathy, or podiatric medicine. (a) Standard: Plan of care. The plan of... treatments, any safety measures to protect against injury, instructions for timely discharge or referral, and...

  4. EVALUATION OF ARG-1 SAMPLES PREPARED BY CESIUM CARBONATE DISSOLUTION DURING THE ISOLOK SME ACCEPTABILITY TESTING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwards, T.; Hera, K.; Coleman, C.

    2011-12-05

    Evaluation of Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) cycle time identified several opportunities to improve the CPC processing time. The Mechanical Systems & Custom Equipment Development (MS&CED) Section of the Savannah River National Laboratory (SRNL) recently completed the evaluation of one of these opportunities - the possibility of using an Isolok sampling valve as an alternative to the Hydragard valve for taking DWPF process samples at the Slurry Mix Evaporator (SME). The use of an Isolok for SME sampling has the potential to improve operability, reduce maintenance time, and decrease CPC cycle time. The SME acceptability testingmore » for the Isolok was requested in Task Technical Request (TTR) HLW-DWPF-TTR-2010-0036 and was conducted as outlined in Task Technical and Quality Assurance Plan (TTQAP) SRNLRP-2011-00145. RW-0333P QA requirements applied to the task, and the results from the investigation were documented in SRNL-STI-2011-00693. Measurement of the chemical composition of study samples was a critical component of the SME acceptability testing of the Isolok. A sampling and analytical plan supported the investigation with the analytical plan directing that the study samples be prepared by a cesium carbonate (Cs{sub 2}CO{sub 3}) fusion dissolution method and analyzed by Inductively Coupled Plasma - Optical Emission Spectroscopy (ICP-OES). The use of the cesium carbonate preparation method for the Isolok testing provided an opportunity for an additional assessment of this dissolution method, which is being investigated as a potential replacement for the two methods (i.e., sodium peroxide fusion and mixed acid dissolution) that have been used at the DWPF for the analysis of SME samples. Earlier testing of the Cs{sub 2}CO{sub 3} method yielded promising results which led to a TTR from Savannah River Remediation, LLC (SRR) to SRNL for additional support and an associated TTQAP to direct the SRNL efforts. A technical report

  5. NEVADA TEST SITE WASTE ACCEPTANCE CRITERIA, JUNE 2006

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    U.S. DEPARTMENT OF ENERGY, NATIONAL NUCLEAR SECURITY ADMINISTRATION NEVADA SITE OFFICE

    This document establishes the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) waste acceptance criteria (WAC). The WAC provides the requirements, terms, and conditions under which the Nevada Test Site (NTS) will accept low-level radioactive (LLW) and mixed waste (MW) for disposal. It includes requirements for the generator waste certification program, characterization, traceability, waste form, packaging, and transfer. The criteria apply to radioactive waste received at the NTS Area 3 and Area 5 Radioactive Waste Management Complex (RWMC) for storage or disposal.

  6. 30 CFR 282.23 - Testing Plan.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Testing Plan. 282.23 Section 282.23 Mineral... § 282.23 Testing Plan. All testing activities shall be conducted in accordance with a Testing Plan..., to carry out a pilot program to evaluate processing techniques or technology or mining equipment, or...

  7. Are the lowest-cost healthful food plans culturally and socially acceptable?

    PubMed Central

    Maillot, Matthieu; Darmon, Nicole; Drewnowski, Adam

    2014-01-01

    Objective Nutritious yet inexpensive foods do exist. However, many such foods are rejected by the low-income consumer. Is it because their use violates unspoken social norms? The present study was designed to assess the variety and cost of the lowest-cost market basket of foods that simultaneously met required dietary standards and progressively stricter consumption constraints. Design A mathematical optimisation model was used to develop the lowest-cost food plans to meet three levels of nutritional requirements and seven levels of consumption constraints. Subjects: The nationally representative INCA (National Individual Survey of Food Consumption) dietary survey study of 1332 adults provided population estimates of food consumption patterns in France. Food plan costs were based on retail food prices. Results The lowest-cost food plans that provided 9204 kJ/d (2200 kcal/d) for men and 7531 kJ/d (1800 kcal/d) for women and met specified dietary standards could be obtained for ,1?50 h/d. The progressive imposition of consumption constraints designed to create more mainstream French diets sharply increased food plan costs, without improving nutritional value. Conclusions Minimising diet costs, while meeting nutrition standards only, led to food plans that provided little variety and deviated substantially from social norms. Aligning the food plan with mainstream consumption led to higher costs. Food plans designed for low-income groups need to be socially acceptable as well as affordable and nutritious. PMID:20105388

  8. Acceptance of family planning methods by induced abortion seekers: An observational study over five years.

    PubMed

    Kathpalia, S K

    2016-01-01

    Prior to legalization of abortion, induced abortions were performed in an illegal manner and that resulted in many complications hence abortion was legalized in India in 1971 and the number of induced abortions has been gradually increasing since then. One way of preventing abortions is to provide family planning services to these abortion seekers so that same is not repeated. The study was performed to find out the acceptance of contraception after abortion. A prospective study was performed over a period of five years from 2010 to 2014. The study group included all the cases reporting for abortion. A proforma was filled in detail to find out the type of contraception being used before pregnancy and acceptance of contraception after abortion. The existing facilities were also evaluated. 1228 abortions were performed over a period of five years. 94.5% of abortions were during the first trimester. 39.9% had not used any contraceptive before, contraceptives used were natural and barrier which had high failure. The main indication for seeking abortion was failure of contraception and completion of family. 39.6% of patients accepted sterilization as a method of contraception. The existing post abortion family planning services are inadequate. Post abortion period is one which is important to prevent subsequent abortions and family planning services after abortion need to be strengthened.

  9. Acceptance of family planning methods by induced abortion seekers: An observational study over five years

    PubMed Central

    Kathpalia, S.K.

    2016-01-01

    Background Prior to legalization of abortion, induced abortions were performed in an illegal manner and that resulted in many complications hence abortion was legalized in India in 1971 and the number of induced abortions has been gradually increasing since then. One way of preventing abortions is to provide family planning services to these abortion seekers so that same is not repeated. The study was performed to find out the acceptance of contraception after abortion. Methods A prospective study was performed over a period of five years from 2010 to 2014. The study group included all the cases reporting for abortion. A proforma was filled in detail to find out the type of contraception being used before pregnancy and acceptance of contraception after abortion. The existing facilities were also evaluated. Results 1228 abortions were performed over a period of five years. 94.5% of abortions were during the first trimester. 39.9% had not used any contraceptive before, contraceptives used were natural and barrier which had high failure. The main indication for seeking abortion was failure of contraception and completion of family. 39.6% of patients accepted sterilization as a method of contraception. The existing post abortion family planning services are inadequate. Conclusion Post abortion period is one which is important to prevent subsequent abortions and family planning services after abortion need to be strengthened. PMID:26900216

  10. Proceedings - Limits of Acceptable Change and related planning processes: Progress and future directions

    Treesearch

    Stephen F. McCool; David N. Cole

    1997-01-01

    Experience with Limits of Acceptable Change (LAC) and related planning processes has accumulated since the mid-1980's. These processes were developoed as a means of dealing with recreation carrying capacity issues in wilderness and National Parks. These processes clearly also have application outside of protected areas and to issues other than recreation...

  11. Acceptance test report for portable exhauster POR-007/Skid E

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kriskovich, J.R.

    1998-07-24

    This document describes Acceptance Testing performed on Portable Exhauster POR-007/Skid E. It includes measurements of bearing vibration levels, pressure decay testing, programmable logic controller interlocks, high vacuum, flow and pressure control functional testing. The purpose of Acceptance testing documented by this report was to demonstrate compliance of the exhausters with the performance criteria established within HNF-0490, Rev. 1 following a repair and upgrade effort at Hanford. In addition, data obtained during this testing is required for the resolution of outstanding Non-conformance Reports (NCR), and finally, to demonstrate the functionality of the associated software for the pressure control and high vacuummore » exhauster operating modes provided for by W-320. Additional testing not required by the ATP was also performed to assist in the disposition and close out of receiving inspection report and for application design information (system curve). Results of this testing are also captured within this document.« less

  12. KSC 50-MHz Doppler Radar Wind Profiler (DRWP) Operational Acceptance Test (OAT) Report

    NASA Technical Reports Server (NTRS)

    Barbre, Robert E.

    2015-01-01

    This report documents analysis results of the Kennedy Space Center updated 50-MHz Doppler Radar Wind Profiler (DRWP) Operational Acceptance Test (OAT). This test was designed to demonstrate that the new DRWP operates in a similar manner to the previous DRWP for use as a situational awareness asset for mission operations at the Eastern Range to identify rapid changes in the wind environment that weather balloons cannot depict. Data examination and two analyses showed that the updated DRWP meets the specifications in the OAT test plan and performs at least as well as the previous DRWP. Data examination verified that the DRWP provides complete profiles every five minutes from 1.8-19.5 km in vertical increments of 150 m. Analysis of 5,426 wind component reports from 49 concurrent DRWP and balloon profiles presented root mean square (RMS) wind component differences around 2.0 m/s. The DRWP's effective vertical resolution (EVR) was found to be 300 m for both the westerly and southerly wind component, which the best EVR possible given the DRWP's vertical sampling interval. A third analysis quantified the sensitivity to rejecting data that do not have adequate signal by assessing the number of first-guess propagations at each altitude. This report documents the data, quality control procedures, methodology, and results of each analysis. It also shows that analysis of the updated DRWP produced results that were at least as good as the previous DRWP with proper rationale. The report recommends acceptance of the updated DRWP for situational awareness usage as per the OAT's intent.

  13. Enraf Series 854 advanced technology gauge (ATG) acceptance test procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huber, J.H.

    1996-09-11

    This Acceptance Test Procedure was written to test the Enraf Series 854 Advanced Technology Gauge (ATG) prior to installation in the Tank Farms. The procedure sets various parameters and verifies that the gauge is functional.

  14. Acceptability of a text message-based fertility awareness application for family planning in Lucknow, India.

    PubMed

    Lerma, Klaira; Reyes, Griselda; Tiwari, Siddharth; Tewari, Akhilesh; Hastings, Charlotte; Blumenthal, Paul D

    2018-03-25

    To assess user satisfaction and acceptability toward a cell phone-based short message system (SMS) application for fertility awareness. Between July 1 and September 30, 2013, the present observational study recruited women of reproductive age who were presenting for family planning services in Lucknow, India, who were not pregnant, agreed to use the application, and understood basic English. The application collected information on an individual's menstrual cycle and, using the calendar days approach, predicted fertility. Based on an algorithm, the application sent a daily SMS text indicating the participant's fertility status. Participants completed an acceptability survey at the end of the 60-day pilot period. There were 21 participants enrolled. All reported that the application was highly acceptable, and found it to be private, secure, and convenient. All participants were interested in receiving future SMS reminders for tracking fertility. Most participants (20 [95%]) reported being likely or very likely to recommend the family planning application to friends. The application, with the aims of helping participants to identify their most fertile days once a month during ovulation and make informed decisions regarding fertility and contraception, was highly acceptable and might be useful in low-resource settings worldwide. Larger studies are needed for software optimization and determination of long-term effectiveness. © 2018 International Federation of Gynecology and Obstetrics.

  15. Antenna Test Facility (ATF): User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Lin, Greg

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the ATF. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  16. Structures Test Laboratory (STL). User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Zipay, John J.

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the STL. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  17. Local tolerance testing under REACH: Accepted non-animal methods are not on equal footing with animal tests.

    PubMed

    Sauer, Ursula G; Hill, Erin H; Curren, Rodger D; Raabe, Hans A; Kolle, Susanne N; Teubner, Wera; Mehling, Annette; Landsiedel, Robert

    2016-07-01

    In general, no single non-animal method can cover the complexity of any given animal test. Therefore, fixed sets of in vitro (and in chemico) methods have been combined into testing strategies for skin and eye irritation and skin sensitisation testing, with pre-defined prediction models for substance classification. Many of these methods have been adopted as OECD test guidelines. Various testing strategies have been successfully validated in extensive in-house and inter-laboratory studies, but they have not yet received formal acceptance for substance classification. Therefore, under the European REACH Regulation, data from testing strategies can, in general, only be used in so-called weight-of-evidence approaches. While animal testing data generated under the specific REACH information requirements are per se sufficient, the sufficiency of weight-of-evidence approaches can be questioned under the REACH system, and further animal testing can be required. This constitutes an imbalance between the regulatory acceptance of data from approved non-animal methods and animal tests that is not justified on scientific grounds. To ensure that testing strategies for local tolerance testing truly serve to replace animal testing for the REACH registration 2018 deadline (when the majority of existing chemicals have to be registered), clarity on their regulatory acceptance as complete replacements is urgently required. 2016 FRAME.

  18. Patient acceptance of non-invasive testing for fetal aneuploidy via cell-free fetal DNA.

    PubMed

    Vahanian, Sevan A; Baraa Allaf, M; Yeh, Corinne; Chavez, Martin R; Kinzler, Wendy L; Vintzileos, Anthony M

    2014-01-01

    To evaluate factors associated with patient acceptance of noninvasive prenatal testing for trisomy 21, 18 and 13 via cell-free fetal DNA. This was a retrospective study of all patients who were offered noninvasive prenatal testing at a single institution from 1 March 2012 to 2 July 2012. Patients were identified through our perinatal ultrasound database; demographic information, testing indication and insurance coverage were compared between patients who accepted the test and those who declined. Parametric and nonparametric tests were used as appropriate. Significant variables were assessed using multivariate logistic regression. The value p < 0.05 was considered significant. Two hundred thirty-five patients were offered noninvasive prenatal testing. Ninety-three patients (40%) accepted testing and 142 (60%) declined. Women who accepted noninvasive prenatal testing were more commonly white, had private insurance and had more than one testing indication. There was no statistical difference in the number or the type of testing indications. Multivariable logistic regression analysis was then used to assess individual variables. After controlling for race, patients with public insurance were 83% less likely to accept noninvasive prenatal testing than those with private insurance (3% vs. 97%, adjusted RR 0.17, 95% CI 0.05-0.62). In our population, having public insurance was the factor most strongly associated with declining noninvasive prenatal testing.

  19. 46 CFR 54.05-17 - Weld toughness test acceptance criteria.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Weld toughness test acceptance criteria. 54.05-17 Section 54.05-17 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING... impact tests the energy absorbed in both the weld metal and heat affected zone impact tests in weld...

  20. 46 CFR 54.05-17 - Weld toughness test acceptance criteria.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Weld toughness test acceptance criteria. 54.05-17 Section 54.05-17 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING... impact tests the energy absorbed in both the weld metal and heat affected zone impact tests in weld...

  1. 46 CFR 54.05-17 - Weld toughness test acceptance criteria.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Weld toughness test acceptance criteria. 54.05-17 Section 54.05-17 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING... impact tests the energy absorbed in both the weld metal and heat affected zone impact tests in weld...

  2. 46 CFR 54.05-17 - Weld toughness test acceptance criteria.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Weld toughness test acceptance criteria. 54.05-17 Section 54.05-17 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING... impact tests the energy absorbed in both the weld metal and heat affected zone impact tests in weld...

  3. 46 CFR 54.05-17 - Weld toughness test acceptance criteria.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Weld toughness test acceptance criteria. 54.05-17 Section 54.05-17 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING... impact tests the energy absorbed in both the weld metal and heat affected zone impact tests in weld...

  4. Regulatory perspectives on acceptability testing of dosage forms in children.

    PubMed

    Kozarewicz, Piotr

    2014-08-05

    Current knowledge about the age-appropriateness of different dosage forms is still fragmented or limited. Applicants are asked to demonstrate that the target age group(s) can manage the dosage form or propose an alternative strategy. However, questions remain about how far the applicant must go and what percentage of patients must find the strategy 'acceptable'. The aim of this overview is to provide an update on current thinking and understanding of the problem, and discuss issues relating to the acceptability testing. This overview should be considered as means to start a wider discussion which hopefully will result in a harmonised, globally acceptable approach for confirmation of the acceptability in the future. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Acceptability and feasibility of HIV testing in general medicine by ELISA or rapid test from finger-stick whole blood.

    PubMed

    Demorat, Hubert; Lopes, Amanda; Chopin, Dorothée; Delcey, Véronique; Clevenbergh, Philippe; Simoneau, Guy; Evans, John; Mouly, Stéphane; Bergmann, Jean-François; Sellier, Pierre

    2018-02-01

    Guidelines recommend routine universal HIV testing in adults to reduce the pool of infected patients unaware of their status, without specific recommendations concerning the method. We compared acceptability and feasibility of HIV testing by ELISA tests or rapid tests from finger-stick whole blood. Prospective randomized multi-center study comparing acceptability and feasibility of routine universal HIV testing by ELISA tests, with a charge, subsequently reimbursed by Social Security for affiliated patients, or rapid tests from finger-stick whole blood, without any charge from the patients or the general practitioner for the study. A single investigator performed all interventions. After consent, all adults (18-70 years old) consulting their general practitioner in Paris, France, unaware of their status, were enrolled. Testing was performed immediately for the patients in the rapid test arm; a prescription was given for testing in a lab for the patients in the ELISA arm. The primary endpoint was acceptability of each method. The secondary endpoint was feasibility of each method, assessed one month after the consultation. Two hundred and seventy patients were enrolled: 133 patients in the ELISA arm, 137 in the rapid test arm. Acceptability of the rapid test (92%) was higher than that of the ELISA (63.9%), P<0.0001. Feasibility of the rapid test (100%) was higher than that of the ELISA (50.5%), P<0.0001. A center effect was shown concerning feasibility of ELISA but not concerning feasibility of rapid tests. Rapid testing from finger-stick whole blood is more acceptable and feasible than ELISA for routine universal HIV testing. A larger use of rapid tests, ideally free of charge, by general practitioners could reduce the pool of infected patients unaware of their status. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  6. Intelligent Network Flow Optimization (INFLO) prototype acceptance test summary.

    DOT National Transportation Integrated Search

    2015-05-01

    This report summarizes the results of System Acceptance Testing for the implementation of the Intelligent Network Flow Optimization (INFLO) Prototype bundle within the Dynamic Mobility Applications (DMA) portion of the Connected Vehicle Program. This...

  7. DiAlert: a prevention program for overweight first degree relatives of type 2 diabetes patients: results of a pilot study to test feasibility and acceptability.

    PubMed

    Heideman, Wieke H; de Wit, Maartje; Middelkoop, Barend J C; Nierkens, Vera; Stronks, Karien; Verhoeff, Arnoud P; Snoek, Frank J

    2012-09-27

    Prevalence of type 2 diabetes mellitus is increasing due to lifestyle changes, particularly affecting those genetically at risk. We developed DiAlert as a targeted group-based intervention aimed to promote intrinsic motivation and action planning for lifestyle changes and weight loss in first degree relatives of patients with type 2 diabetes mellitus.The main objective of the pilot of the DiAlert intervention was to assess fidelity, feasibility and acceptability prior to starting the randomized controlled trial. Individuals with a family history of type 2 diabetes mellitus were self-identified and screened for eligibility. DiAlert consists of two group sessions. Feasibility, fidelity, acceptability and self-reported perceptions and behavioral determinants were evaluated in a pre-post study using questionnaires and observations. Determinants of behavior change were analyzed using paired-samples t tests and Wilcoxon signed rank tests. DiAlert was delivered to two groups of first degree relatives of patients with type 2 diabetes mellitus (N = 9 and N = 12). Feasibility and fidelity were confirmed. Overall, the DiAlert group sessions were positively evaluated (8.0 on a scale of 1 to 10) by participants. The intervention did not impact perceived susceptibility or worry about personal diabetes risk. Action planning with regard to changing diet and physical activity increased. DiAlert proved feasible and was well-accepted by participants. Positive trends in action planning indicate increased likelihood of actual behavior change following DiAlert. Testing the effectiveness in a randomized controlled trial is imperative. Netherlands National Trial Register (NTR): NTR2036.

  8. China SLAT Plan Template

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dietrich, Richard E.

    2016-07-01

    This document serves as the System-Level Acceptance Test (SLAT) Plan for Site Name, City, Country. This test plan is to provide independent testing of the Radiation Detection System (RDS) installed at Site Name to verify that Customs has been delivered a fully-functioning system as required by all contractual commitments. The system includes all installed hardware and software components. The SLAT plan will verify that separate components are working individually and collectively from a system perspective.

  9. Acceptance test report for portable exhauster POR-008/Skid F

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kriskovich, J.R.

    1998-07-24

    Portable Exhauster POR-008 was procured via HNF-0490, Specification for a Portable Exhausted System for Waste Tank Ventilation. Prior to taking ownership, acceptance testing was performed at the vendors. However at the conclusion of testing a number of issues remained that required resolution before the exhausters could be used by Project W-320. The purpose of acceptance testing documented by this report was to demonstrate compliance of the exhausters with the performance criteria established within HNF-O49O, Rev. 1 following a repair and upgrade effort at Hanford. In addition, data obtained during this testing is required for the resolution of outstanding Non-conformance Reportsmore » (NCR), and finally, to demonstrate the functionality of the associated software for the pressure control and high vacuum exhauster operating modes provided for by W-320. Additional testing not required by the ATP was also performed to assist in the disposition and close out of receiving inspection report and for application design information (system curve). Results of this testing are also captured within this document.« less

  10. 14 CFR 437.25 - Flight test plan.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Flight test plan. 437.25 Section 437.25... TRANSPORTATION LICENSING EXPERIMENTAL PERMITS Requirements to Obtain an Experimental Permit Flight Test Plan § 437.25 Flight test plan. An applicant must— (a) Describe any flight test program, including estimated...

  11. 14 CFR 437.25 - Flight test plan.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false Flight test plan. 437.25 Section 437.25... TRANSPORTATION LICENSING EXPERIMENTAL PERMITS Requirements to Obtain an Experimental Permit Flight Test Plan § 437.25 Flight test plan. An applicant must— (a) Describe any flight test program, including estimated...

  12. 14 CFR 437.25 - Flight test plan.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 4 2012-01-01 2012-01-01 false Flight test plan. 437.25 Section 437.25... TRANSPORTATION LICENSING EXPERIMENTAL PERMITS Requirements to Obtain an Experimental Permit Flight Test Plan § 437.25 Flight test plan. An applicant must— (a) Describe any flight test program, including estimated...

  13. Single Event Effect (SEE) Test Planning 101

    NASA Technical Reports Server (NTRS)

    LaBel, Kenneth A.; Pellish, Jonathan; Berg, Melanie D.

    2011-01-01

    This is a course on SEE Test Plan development. It is an introductory discussion of the items that go into planning an SEE test that should complement the SEE test methodology used. Material will only cover heavy ion SEE testing and not proton, LASER, or other though many of the discussed items may be applicable. While standards and guidelines for how-to perform single event effects (SEE) testing have existed almost since the first cyclotron testing, guidance on the development of SEE test plans has not been as easy to find. In this section of the short course, we attempt to rectify this lack. We consider the approach outlined here as a "living" document: mission specific constraints and new technology related issues always need to be taken into account. We note that we will use the term "test planning" in the context of those items being included in a test plan.

  14. 49 CFR 180.511 - Acceptable results of inspections and tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Acceptable results of inspections and tests. 180.511 Section 180.511 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE... results of inspections and tests. Provided it conforms to other applicable requirements of this subchapter...

  15. 49 CFR 180.511 - Acceptable results of inspections and tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Acceptable results of inspections and tests. 180.511 Section 180.511 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE... results of inspections and tests. Provided it conforms to other applicable requirements of this subchapter...

  16. 49 CFR 180.511 - Acceptable results of inspections and tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Acceptable results of inspections and tests. 180.511 Section 180.511 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS... results of inspections and tests. Provided it conforms with other applicable requirements of this...

  17. WRAP low level waste restricted waste management (LLW RWM) glovebox acceptance test report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leist, K.J.

    1997-11-24

    On April 22, 1997, the Low Level Waste Restricted Waste Management (LLW RWM) glovebox was tested using acceptance test procedure 13027A-87. Mr. Robert L. Warmenhoven served as test director, Mr. Kendrick Leist acted as test operator and test witness, and Michael Lane provided miscellaneous software support. The primary focus of the glovebox acceptance test was to examine glovebox control system interlocks, operator Interface Unit (OIU) menus, alarms, and messages. Basic drum port and lift table control sequences were demonstrated. OIU menus, messages, and alarm sequences were examined, with few exceptions noted. Barcode testing was bypassed, due to the lack ofmore » installed equipment as well as the switch from basic reliance on fixed bar code readers to the enhanced use of portable bar code readers. Bar code testing was completed during performance of the LLW RWM OTP. Mechanical and control deficiencies were documented as Test Exceptions during performance of this Acceptance Test. These items are attached as Appendix A to this report.« less

  18. 49 CFR 180.411 - Acceptable results of tests and inspections.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Acceptable results of tests and inspections. 180.411 Section 180.411 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE... results of tests and inspections. (a) Corroded or abraded areas. The minimum thickness may not be less...

  19. 49 CFR 180.411 - Acceptable results of tests and inspections.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Acceptable results of tests and inspections. 180.411 Section 180.411 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE... results of tests and inspections. (a) Corroded or abraded areas. The minimum thickness may not be less...

  20. 49 CFR 180.411 - Acceptable results of tests and inspections.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Acceptable results of tests and inspections. 180.411 Section 180.411 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS... results of tests and inspections. (a) Corroded or abraded areas. The minimum thickness may not be less...

  1. Low acceptance of HSV-2 testing among high-risk women.

    PubMed

    Roth, A M; Dodge, B M; Van Der Pol, B; Reece, M; Zimet, G D

    2011-06-01

    We evaluated the acceptability of a community-based herpes simplex virus type 2 (HSV-2) screening programme for at-risk women and assessed factors related to uptake of point of care HSV-2 testing. One hundred recently arrested women (median age 34 years) were recruited from a community court handling lower-level misdemeanour cases in Indianapolis, Indiana. Individuals completed a survey assessing factors related to HSV-2 screening intentions and were offered point of care HSV-2 testing. Rates of HSV-2 infection in this population are high; 61.1% of women tested were positive. The majority (81%) accepted a prescription for suppressive therapy. Women in this sample indicated that HSV-2 screening is an important component of health care but were unwilling to pay the US$10 it cost to be tested. To encourage this and other high-risk populations to be screened for HSV-2, public health resources will be needed to help individuals overcome cost-related barriers to care.

  2. Factors influencing acceptability of voluntary HIV testing among pregnant women in Gamboma, Republic of Congo.

    PubMed

    Ghoma-Linguissi, Laure Stella; Ebourombi, Dagene Fruinovy; Sidibe, Anissa; Kivouele, Thomas Serge; Vouvoungui, Jeannhey Christevy; Poulain, Pierre; Ntoumi, Francine

    2015-11-06

    This study was carried out to identify factors affecting the acceptability of voluntary HIV testing among pregnant women in a semi-rural city, Gamboma, Republic of Congo. A cross-sectional study was conducted between January and September 2012. Pregnant women attending antenatal heath care at an integrated health center were enrolled after informed consent and followed through voluntary HIV testing. Among 136 participants, 98 women (72 %) accepted voluntary HIV testing after pre-test counseling. Women with basic education, those who cited blood transfusion as a mode of transmission and prevention of mother-to-child transmission (MTCT) were more likely to accept testing as well those informed about free HIV testing. Interestingly, pregnant women who had heard about HIV/AIDS from hospital setting were less likely to accept testing. Our data indicate that increasing general education on HIV transmission/prevention modes is crucial for increasing acceptability of screening. Furthermore, HIV/AIDS knowledge disseminated to patients in hospital settings should be carefully monitored. Lastly, scaling-up MTCT services along with a better and larger community information, may address accessibility barriers observed in the present study.

  3. TESTING AND ACCEPTANCE OF FUEL PLATES FOR RERTR FUEL DEVELOPMENT EXPERIMENTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J.M. Wight; G.A. Moore; S.C. Taylor

    2008-10-01

    This paper discusses how candidate fuel plates for RERTR Fuel Development experiments are examined and tested for acceptance prior to reactor insertion. These tests include destructive and nondestructive examinations (DE and NDE). The DE includes blister annealing for dispersion fuel plates, bend testing of adjacent cladding, and microscopic examination of archive fuel plates. The NDE includes Ultrasonic (UT) scanning and radiography. UT tests include an ultrasonic scan for areas of “debonds” and a high frequency ultrasonic scan to determine the "minimum cladding" over the fuel. Radiography inspections include identifying fuel outside of the maximum fuel zone and measurements and calculationsmore » for fuel density. Details of each test are provided and acceptance criteria are defined. These tests help to provide a high level of confidence the fuel plate will perform in the reactor without a breach in the cladding.« less

  4. Developing an acceptability assessment of preventive dental treatments.

    PubMed

    Hyde, Susan; Gansky, Stuart A; Gonzalez-Vargas, Maria J; Husting, Sheila R; Cheng, Nancy F; Millstein, Susan G; Adams, Sally H

    2009-01-01

    Early childhood caries (ECC) is very prevalent among young Hispanic children. ECC is amenable to a variety of preventive procedures, yet many Hispanic families underutilize dental services. Acceptability research may assist in health care planning and resource allocation by identifying patient preferences among efficacious treatments with the goal of improving their utilization. The purposes of this study were (a) to develop a culturally competent acceptability assessment instrument, directed toward the caregivers of young Hispanic children, for five preventive dental treatments for ECC and (b) to test the instrument's reliability and validity. An instrument of five standard treatments known to prevent ECC was developed, translated, reviewed by focus groups, and pilot tested, then tested for reliability The instrument included illustrated cards, brief video clips, and samples of the treatments and was culturally appropriate for low-income Hispanic caregivers. In addition to determining the acceptability of the five treatments individually, the treatments were also presented as paired comparisons. Focus groups and debriefing interviews following the pilot tests established that the instrument has good face validity. The illustrated cards, product samples, and video demonstrations of the five treatments resulted in an instrument possessing good content validity. The instrument has good to excellent test-retest reliability, with identical time 1-time 2 responses for each of the five treatments 92 percent of the time (range 87 to 97 percent), and the same treatment of the paired comparisons preferred 75 percent of the time (range 61 to 90 percent). The acceptability instrument described is reliable and valid and may be useful in program planning efforts to identify and increase the utilization of preferred ECC preventive treatments for target populations.

  5. 7 CFR 1210.323 - Acceptance.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Acceptance. 1210.323 Section 1210.323 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS... PLAN Watermelon Research and Promotion Plan National Watermelon Promotion Board § 1210.323 Acceptance...

  6. Radiant Heat Test Facility (RHTF): User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    DelPapa, Steven

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the RHTF. The User Test Planning Guide aids in establishing expectations for both NASA and non- NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  7. Electronic Systems Test Laboratory (ESTL) User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Robinson, Neil

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the ESTL. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  8. 78 FR 38411 - Vogtle Electric Generating Plant, Unit 4; Inspections, Tests, Analyses, and Acceptance Criteria

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-26

    ... Plant, Unit 4; Inspections, Tests, Analyses, and Acceptance Criteria AGENCY: Nuclear Regulatory Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria completion. SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) staff has determined that the inspections, tests...

  9. 242A Distributed Control System Year 2000 Acceptance Test Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    TEATS, M.C.

    1999-08-31

    This report documents acceptance test results for the 242-A Evaporator distributive control system upgrade to D/3 version 9.0-2 for year 2000 compliance. This report documents the test results obtained by acceptance testing as directed by procedure HNF-2695. This verification procedure will document the initial testing and evaluation of the potential 242-A Distributed Control System (DCS) operating difficulties across the year 2000 boundary and the calendar adjustments needed for the leap year. Baseline system performance data will be recorded using current, as-is operating system software. Data will also be collected for operating system software that has been modified to correct yearmore » 2000 problems. This verification procedure is intended to be generic such that it may be performed on any D/3{trademark} (GSE Process Solutions, Inc.) distributed control system that runs with the VMSTM (Digital Equipment Corporation) operating system. This test may be run on simulation or production systems depending upon facility status. On production systems, DCS outages will occur nine times throughout performance of the test. These outages are expected to last about 10 minutes each.« less

  10. Acceptance-test report for El Toro Library solar heating and cooling demonstration project (SHAC no. 1501)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    A partial acceptance test was conducted on the El Toro Library Solar Energy System, and the detailed results of the various mode acceptance tests are given. All the modes tested function as designed. Collector array efficiencies were calculated at approximately 40%. Chiller COP was estimated at .50, with chiller loop flow rates approximately 85 to 90% of design flow. The acceptance test included visual inspection, preoperational testing and procedure verification, operational mode checkout, and performance testing. (LEW)

  11. Specialized Environmental Chamber Test Complex: User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Montz, Michael E.

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the Specialized Environmental Test Complex. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  12. Preliminary DICOM acceptance testing using the central test node

    NASA Astrophysics Data System (ADS)

    Chimiak, William J.

    1996-05-01

    The Bowman Gray School of Medicine of Wake Forest University (BGSM) is installing clinical DICOM workstations and DICOM film digitizers for use in a telemedicine trial over the North Carolina ATM infrastructure. Acquiring equipment thought to be DICOM compliant, but which does not live up to expectations and possibly fails to interoperate with other DICOM equipment, is a concern. In cooperation with RSNA and the Mallinckrodt Institute of Radiology of the Washington University School of Medicine (MIR), BGSM made acceptance of the CEMAX workstations for the telemedicine trial contingent upon a satisfactory test with the MIR central test node (CTN). During the test, both engineers never left their hospitals during the tests drastically cutting travel and per diem costs and valuable time. The successful results exceeded expectations. Images were not only passed back and forth to the CTN by both the CEMAX clinical workstation and the quality assurance workstation, but images arriving from the CTN were entered into the CEMAX clinical database without operator intervention. It was expected that the images would transfer, but the placement into the database, although reasonable to expect, actually occurred. This live test from an independent test source exhibited the ease with which the CEMAX workstations handled the DICOM images in their systems. In the test, the CEMAX workstations were configured as an exporter of DICOM images at BGSM. The CTN was entered in the configuration of the CEMAX workstations as a source of DICOM images. The test was to ensure that plain film, computed tomography, and magnetic resonance images could be easily exchanged between workstations electronically. This paper describes the procedure for using the CTN to provide preliminary testing of DICOM equipment.

  13. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid Q

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    KOCH, M.R.

    2000-03-27

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''Q''. The ATP will be performed after the construction of the PIC skid in the fabrication shop.

  14. Fabrication Control Plan for ORNL RH-LOCA ATF Test Specimens to be Irradiated in the ATR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Field, Kevin G.; Howard, Richard; Teague, Michael

    2014-06-01

    The purpose of this fabrication plan is (1) to summarize the design of a set of rodlets that will be fabricated and then irradiated in the Advanced Test Reactor (ATR) and (2) provide requirements for fabrication and acceptance criteria for inspections of the Light Water Reactor (LWR) – Accident Tolerant Fuels (ATF) rodlet components. The functional and operational (F&OR) requirements for the ATF program are identified in the ATF Test Plan. The scope of this document only covers fabrication and inspections of rodlet components detailed in drawings 604496 and 604497. It does not cover the assembly of these items tomore » form a completed test irradiation assembly or the inspection of the final assembly, which will be included in a separate INL final test assembly specification/inspection document. The controls support the requirements that the test irradiations must be performed safely and that subsequent examinations must provide valid results.« less

  15. When is diagnostic testing inappropriate or irrational? Acceptable regret approach.

    PubMed

    Hozo, Iztok; Djulbegovic, Benjamin

    2008-01-01

    The authors provide a new model within the framework of theories of bounded rationality for the observed physicians' behavior that their ordering of diagnostic tests may not be rational. Contrary to the prevailing thinking, the authors find that physicians do not act irrationally or inappropriately when they order diagnostic tests in usual clinical practice. When acceptable regret (i.e., regret that a decision maker finds tolerable upon making a wrong decision) is taken into account, the authors show that physicians tend to order diagnostic tests at a higher level of pretest probability of disease than predicted by expected utility theory. They also show why physicians tend to overtest when regret about erroneous decisions is extremely small. Finally, they explain variations in the practice of medicine. They demonstrate that in the same clinical situation, different decision makers might have different acceptable regret thresholds for withholding treatment, for ordering a diagnostic test, or for administering treatment. This in turn means that for some decision makers, the most rational strategy is to do nothing, whereas for others, it may be to order a diagnostic test, and still for others, choosing treatment may be the most rational course of action.

  16. Geoscience Laser Altimeter System (GLAS) Instrument: Flight Loop Heat Pipe (LHP) Acceptance Thermal Vacuum Test

    NASA Technical Reports Server (NTRS)

    Baker, Charles; Butler, Dan; Ku, Jentung; Grob, Eric; Swanson, Ted; Nikitkin, Michael; Powers, Edward I. (Technical Monitor)

    2001-01-01

    Two loop heat pipes (LHPs) are to be used for tight thermal control of the Geoscience Laser Altimeter System (GLAS) instrument, planned for flight in late 2001. The LHPs are charged with Propylene as a working fluid. One LHP will be used to transport 110 W from a laser to a radiator, the other will transport 160 W from electronic boxes to a separate radiator. The application includes a large amount of thermal mass in each LHP system and low initial startup powers. The initial design had some non-ideal flight design compromises, resulted in a less than ideal charge level for this design concept with a symmetrical secondary wick. This less than ideal charge was identified as the source of inadequate performance of the flight LHPs during the flight thermal vacuum test in October of 2000. We modified the compensation chamber design, re-built and charged the LHPs for a final LHP acceptance thermal vacuum test. This test performed March of 2001 was 100% successful. This is the last testing to be performed on the LHPs prior to instrument thermal vacuum test. This sensitivity to charge level was shown through varying the charge on a Development Model Loop Heat Pipe (DM LHP) and evaluating performance at various fill levels. At lower fills similar to the original charge in the flight units, the same poor performance was observed. When the flight units were re-designed and filled to the levels similar to the initial successful DM LHP test, the flight units also successfully fulfilled all requirements. This final flight Acceptance test assessed performance with respect to startup, low power operation, conductance, and control heater power, and steady state control. The results of the testing showed that both LHPs operated within specification. Startup on one of the LHPs was better than the other LHP because of the starter heater placement and a difference in evaporator design. These differences resulted in a variation in the achieved superheat prior to startup. The LHP with

  17. Implementation and acceptability of strategies instituted for engaging men in family planning services in Kibaha district, Tanzania.

    PubMed

    Msovela, Judith; Tengia-Kessy, Anna

    2016-11-21

    Men as the main decision makers in most of African families have an important role to play towards acceptance of family planning methods. This study sought to identify strategies used to engage men in family planning services and determine the extent to which men in Kibaha district in Tanzania accept these interventions. We conducted a cross sectional study using both quantitative and qualitative techniques. We used a questionnaire to interview a random sample of 365 of currently married or cohabiting men who had at least one child under the age of five years. We further conducted in-depth interviews with health workers involved in delivering reproductive health services as well as community dispensers of family planning commodities. Descriptive analysis was used to determine the extent to which men were engaged in family planning services. The data from the indepth interviews were analysed manually according to the predetermined themes, guided by the grounded theory to identify the existing strategies used to encourage male involvement in family planning services. According to the key informants, strategies that are used to encourage men to engage in family planning services include invitations through their spouses, either verbally or by using partner notification cards, incorporating family planning messages during monthly meetings and community outreach reproductive health programs. Of 365 men responding to the questionnaire, only 31 (8.4%) said they were invited to accompany their spouses to family planning clinics. Among them, 71% (22/31) visited family planning clinics. A third (32%) of the respondents had heard of community health meetings and only 20.7% of them attended these meetings. More than a third (12/34) of men who attended these meeting asserted that family planning messages targeting men featured in the agenda and subsequently half of them visited health facilities for family planning services. Existing strategies such as invitations to clinics

  18. Energy Systems Test Area (ESTA) Battery Test Operations User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Salinas, Michael

    2012-01-01

    Test process, milestones and inputs are unknowns to first-time users of the ESTA Battery Test Operations. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  19. Acceptance Testing of Thermoluminescent Dosimeter Holders.

    PubMed

    Romanyukha, Alexander; Grypp, Matthew D; Sharp, Thad J; DiRito, John N; Nelson, Martin E; Mavrogianis, Stanley T; Torres, Jeancarlo; Benevides, Luis A

    2018-05-01

    The U.S. Navy uses the Harshaw 8840/8841 dosimetric (DT-702/PD) system, which employs LiF:Mg,Cu,P thermoluminescent dosimeters (TLDs), developed and produced by Thermo Fisher Scientific (TFS). The dosimeter consists of four LiF:Mg,Cu,P elements, mounted in Teflon® on an aluminum card and placed in a plastic holder. The holder contains a unique filter for each chip made of copper, acrylonitrile butadiene styrene (ABS), Mylar®, and tin. For accredited dosimetry labs, the ISO/IEC 17025:2005(E) requires an acceptance procedure for all new equipment. The Naval Dosimetry Center (NDC) has developed and tested a new non-destructive procedure, which enables the verification and the evaluation of embedded filters in the holders. Testing is based on attenuation measurements of low-energy radiation transmitted through each filter in a representative sample group of holders to verify that the correct filter type and thickness are present. The measured response ratios are then compared with the expected response ratios. In addition, each element's measured response is compared to the mean response of the group. The test was designed and tested to identify significant nonconformities, such as missing copper or tin filters, double copper or double tin filters, or other nonconformities that may impact TLD response ratios. During the implementation of the developed procedure, testing revealed a holder with a double copper filter. To complete the evaluation, the impact of the nonconformities on proficiency testing was examined. The evaluation revealed failures in proficiency testing categories III and IV when these dosimeters were irradiated to high-energy betas.

  20. ENRAF Series 854 Advanced Technology Gauge (ATG) Acceptance Test Procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    HUBER, J.H.

    1999-08-17

    This procedure provides acceptance testing for Enraf Series 854 level gauges used to monitor levels in Hanford Waste Storage Tanks. The test will verify that the gauge functions according to the manufacturer's instructions and specifications and is properly setup prior to being delivered to the tank farm area. This ATP does not set up the gauge for any specific tank, but is generalized to permit testing the gauge prior to installation package preparation.

  1. Acceptance of HIV testing among women attending antenatal care in south-western Uganda: risk factors and reasons for test refusal.

    PubMed

    Dahl, V; Mellhammar, L; Bajunirwe, F; Björkman, P

    2008-07-01

    A problem commonly encountered in programs for prevention of mother-to-child-transmission (PMTCT) of HIV in sub-Saharan Africa is low rates of HIV test acceptance among pregnant women. In this study, we examined risk factors and reasons for HIV test refusal among 432 women attending three antenatal care clinics offering PMTCT in urban and semi-urban parts of the Mbarara district, Uganda. Structured interviews were performed following pre-test counselling. Three-hundred-eighty women were included in the study, 323 (85%) of whom accepted HIV testing. In multivariate analysis, testing site (Site A: OR = 1.0; Site B: OR = 3.08; 95%CI: 1.12-8.46; Site C: OR = 5.93; 95%CI: 2.94-11.98), age between 30 and 34 years (<20 years: OR = 1.0; 20-24 years: OR = 1.81; 95%CI: 0.58-5.67; 25-29 years: OR = 2.15; 95%CI: 0.66-6.97; 30-34 years: OR = 3.88; 95%CI: 1.21-13.41), mistrust in reliability of the HIV test (OR = 20.60; 95%CI: 3.24-131.0) and not having been tested for HIV previously (OR = 2.15; 95%CI: 1.02-4.54) were associated with test refusal. Testing sites operating for longer durations had higher rates of acceptance. The most common reasons claimed for test refusal were: lack of access to antiretroviral therapy (ART) for HIV-infected women (88%; n=57), a need to discuss with partner before decision (82%; n=57) and fear of partner's reaction (54%; n=57). Comparison with previous periods showed that the acceptance rate increased with the duration of the program. Our study identified risk factors for HIV test refusal among pregnant women in Uganda and common reasons for not accepting testing. These findings may suggest modifications and improvements in the performance of HIV testing in this and similar populations.

  2. Objective criteria for acceptability and constancy tests of digital subtraction angiography.

    PubMed

    de las Heras, Hugo; Torres, Ricardo; Fernández-Soto, José Miguel; Vañó, Eliseo

    2016-01-01

    Demonstrate an objective procedure to quantify image quality in digital subtraction angiography (DSA) and suggest thresholds for acceptability and constancy tests. Series of images were obtained in a DSA system simulating a small (paediatric) and a large patient using the dynamic phantom described in the IEC and DIN standards for acceptance tests of DSA equipment. Image quality was quantified using measurements of contrast-to-noise ratio (CNR). Overall scores combining the CNR of 10-100 mg/ml Iodine at a vascular diameter of 1-4 mm in a homogeneous background were defined. Phantom entrance surface air kerma (Ka,e) was measured with an ionisation chamber. The visibility of a low-contrast vessel in DSA images has been identified with a CNR value of 0.50 ± 0.03. Despite using 14 times more Ka,e (8.85 vs 0.63 mGy/image), the protocol for large patients showed a decrease in the overall score CNRsum of 67% (4.21 ± 0.06 vs 2.10 ± 0.05). The uncertainty in the results of the objective method was below 5%. Objective evaluation of DSA images using CNR is feasible with dedicated phantom measurements. An objective methodology has been suggested for acceptance tests compliant with the IEC/DIN standards. The defined overall scores can serve to fix a reproducible baseline for constancy tests, as well as to study the device stability within one acquisition series and compare different imaging protocols. This work provides aspects that have not been included in the recent European guidelines on Criteria for Acceptability of Medical Radiological Equipment. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  3. Acceptance and Commitment Therapy for Inpatients with Psychosis (the REACH Study): Protocol for Treatment Development and Pilot Testing

    PubMed Central

    Gaudiano, Brandon A.; Davis, Carter H.; Epstein-Lubow, Gary; Johnson, Jennifer E.; Mueser, Kim T.; Miller, Ivan W.

    2017-01-01

    Patients with schizophrenia-spectrum disorders frequently require treatment at inpatient hospitals during periods of acute illness for crisis management and stabilization. Acceptance and Commitment Therapy (ACT), a “third wave” cognitive-behavioral intervention that employs innovative mindfulness-based strategies, has shown initial efficacy in randomized controlled trials for improving acute and post-discharge outcomes in patients with psychosis when studied in acute-care psychiatric hospitals in the U.S. However, the intervention has not been widely adopted in its current form because of its use of an individual-only format and delivery by doctoral-level research therapists with extensive prior experience using ACT. The aim of the Researching the Effectiveness of Acceptance-based Coping during Hospitalization (REACH) Study is to adapt a promising acute-care psychosocial treatment for inpatients with psychosis, and to pilot test its effectiveness in a routine inpatient setting. More specifically, we describe our plans to: (a) further develop and refine the treatment and training protocols, (b) conduct an open trial and make further modifications based on the experience gained, and (c) conduct a pilot randomized controlled trial in preparation for a future fully-powered clinical trial testing the effectiveness of ACT. PMID:28475123

  4. Vibration and Acoustic Test Facility (VATF): User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Fantasia, Peter M.

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the VATF. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  5. Redstone Test Stand Accepted Into National Register of Historical Places

    NASA Technical Reports Server (NTRS)

    1976-01-01

    On October 02, 1976, Marshall Space Flight Center's (MSFC) Redstone test stand was received into the National Registry of Historical Places. Photographed in front of the Redstone test stand are Dr. William R. Lucas, MSFC Center Director from June 15, 1974 until July 3, 1986, as he is accepting a certificate of registration from Madison County Commission Chairman James Record, and Huntsville architect Harvie Jones.

  6. Developing an Acceptability Assessment of Preventive Dental Treatments

    PubMed Central

    Hyde, Susan; Gansky, Stuart A.; Gonzalez-Vargas, Maria J.; Husting, Sheila R.; Cheng, Nancy F.; Millstein, Susan G.; Adams, Sally H.

    2012-01-01

    Objectives Early childhood caries (ECC) is very prevalent among young Hispanic children. ECC is amenable to a variety of preventive procedures, yet many Hispanic families underutilize dental services. Acceptability research may assist in health care planning and resource allocation by identifying patient preferences among efficacious treatments with the goal of improving their utilization. The purposes of this study were (a) to develop a culturally competent acceptability assessment instrument, directed toward the caregivers of young Hispanic children, for five preventive dental treatments for ECC and (b) to test the instrument's reliability and validity. Methods An instrument of five standard treatments known to prevent ECC was developed, translated, reviewed by focus groups, and pilot tested, then tested for reliability. The instrument included illustrated cards, brief video clips, and samples of the treatments and was culturally appropriate for low-income Hispanic caregivers. In addition to determining the acceptability of the five treatments individually, the treatments were also presented as paired comparisons. Results Focus groups and debriefing interviews following the pilot tests established that the instrument has good face validity. The illustrated cards, product samples, and video demonstrations of the five treatments resulted in an instrument possessing good content validity. The instrument has good to excellent test–retest reliability, with identical time 1–time 2 responses for each of the five treatments 92 percent of the time (range 87 to 97 percent), and the same treatment of the paired comparisons preferred 75 percent of the time (range 61 to 90 percent). Conclusions The acceptability instrument described is reliable and valid and may be useful in program planning efforts to identify and increase the utilization of preferred ECC preventive treatments for target populations. PMID:18662256

  7. Acceptability of Family-Centered Advanced Care Planning for Adolescents With HIV

    PubMed Central

    Kimmel, Allison; Wilkins, Megan L.; Rana, Sohail; Garcia, Ana; Cheng, Yao I.; Wang, Jichuan; Lyon, Maureen E.

    2016-01-01

    BACKGROUND AND OBJECTIVE: Small pilot studies support the appropriateness of engaging adolescents with chronic or life-limiting illnesses in pediatric advance care planning (pACP). We do not yet know if pACP is acceptable, feasible, and worthwhile, even if emotionally intense, in a fully powered randomized controlled trial. METHODS: We conducted a prospective 2-arm randomized controlled trial at 6 US urban hospitals. Adolescent/family member dyads were randomized to receive the 1-session-a-week 3-session FAmily-CEntered Advance Care Planning (FACE) pACP intervention (1, ACP Survey; 2, Goals of Care Conversation/Treatment Preferences; 3, Completion of Advance Directive) or active comparator (1, Developmental History; 2, Safety Tips; 3, Nutrition/Exercise). The Satisfaction Questionnaire was administered to participants independently after each session by a blinded research assistant. RESULTS: We enrolled 53% of eligible participants and intervened with 97 adolescent/family dyads. Adolescents ranged in age from 14 to 21 years; 54% were male individuals; 93% African American; and 73% perinatally infected. Attendance was 99% for all 3 sessions in each arm. At session 3, FACE adolescents and family dyad members, respectively, found the session useful (98%, 98%) and helpful (98%, 100%), despite feelings of sadness (25%, 17%). FACE adolescents’ improvement in the total subscale A score (useful, helpful, like a load off my mind, satisfied, something I needed to do, courageous, worthwhile) was better than control adolescents at session 3 (β = 1.16, P = .02). There were no adverse events. CONCLUSIONS: FACE enabled worthwhile conversations, while simultaneously eliciting intense emotions. No participants withdrew, 99% of those enrolled completed each session, and there were no adverse events, evidence of pACP’s feasibility, acceptability, and safety. PMID:27940700

  8. PACS: acceptance test, quality control, warranty, and maintenance continuum

    NASA Astrophysics Data System (ADS)

    Romlein, John R.; Norton, Gary S.; Lyche, David K.; Richardson, Ronald R., Jr.

    1999-07-01

    As PACS gain greater acceptance and use in medical facilities the question of life cycle management must be addressed in terms that relate to the common business practices for medical information system and medical devices. The issues in life cycle management of such a system are relatively new to the industry. Increased use of PACS within the medical community requires that standardized life cycle management practices by developed and implemented. This paper develops a new of life cycle issues as cyclic and related events that are not only manageable, but also predictable in terms, of, frequency, duration data content, data exchange, potential outcomes, staffing requirement, documentation, and staff interaction. This view is presented as a continuum that begins at the acceptance testing of a PACS and continues throughout its life cycle. The continuum incorporates the required relationship between quality control testing and maintenance actions during warranty period and the maintenance years. Interrelated cyclic events are described that bind these processes together and provide a basis for long-term proactive management of PACS in a medical environment.

  9. Small, high-pressure ratio compressor mechanical acceptance test, volume 2

    NASA Technical Reports Server (NTRS)

    Metty, G. R.; Shoup, W. I.

    1973-01-01

    The fabrication and mechanical testing of the high-pressure-ratio compressor are reported. Mechanical testing was performed to demonstrate overspeed capability, adequate rotor dynamics, electrical isolation of the gas bearing trunnion mounted diffuser and shroud and the effect of operating parameters (speed and pressure ratio) on clearance of the compressor test rig. The speed range covered was 20 to 120 percent of rated speed (80,000 rpm). Following these tests an acceptance test which consisted of a 5 hour run at 80,000 rpm was made with approximately design impeller to shroud clearances. For Vol. 1, see N73-26483.

  10. Acceptability of VTOL aircraft noise determined by absolute subjective testing

    NASA Technical Reports Server (NTRS)

    Sternfeld, H., Jr.; Hinterkeuser, E. G.; Hackman, R. B.; Davis, J.

    1972-01-01

    A program was conducted during which test subjects evaluated the simulated sounds of a helicopter, a tilt wing aircraft, and a 15 second, 90 PNdB (indoors) turbojet aircraft used as reference. Over 20,000 evaluations were made while the test subjects were engaged in work and leisure activities. The effects of level, exposure time, distance and aircraft design on subjective acceptability were evaluated. Some of the important conclusions are: (1) To be judged equal in annoyance to the reference jet sound, the helicopter and tilt wing sounds must be 4 to 5 PNdB lower when lasting 15 seconds in duration. (2) To be judged significantly more acceptable than the reference jet sound, the helicopter sound must be 10 PNdB lower when lasting 15 seconds in duration. (3) To be judged significantly more acceptable than the reference jet sound, the tilt wing sound must be 12 PNdB lower when lasting 15 seconds in duration. (4) The relative effect of changing the duration of a sound upon its subjectively rated annoyance diminishes with increasing duration. It varies from 2 PNdB per doubling of duration for intervals of 15 to 30 seconds, to 0.75 PNdB per doubling of duration for intervals of 120 to 240 seconds.

  11. Development of Phased-Array Ultrasonic Testing Acceptability Criteria : (Phase II)

    DOT National Transportation Integrated Search

    2014-10-01

    The preliminary technical approach and scan plans developed during phase I of this research was implemented on testing four butt-weld specimens. The ray path analysis carried out to develop the scan plans and the preliminary data analysis indicated t...

  12. Test Series 2. 4: detailed test plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Test Series 2.4 comprises the fourth sub-series of tests to be scheduled as a part of Test Series 2, the second stage of the combustion research program to be carried out at the Grimethorpe Experimental Pressurized Fluidized Bed Combustion Facility. Test Series 2.1, the first sub-series of tests, was completed in February 1983, and the first part of the second sub-series, Test Series 2.3, in October 1983. Test Series 2.2 was completed in February 1984 after which the second part of Test Series 2.3 commenced. The Plan for Test Series 2.4 consists of 350 data gathering hours to be completedmore » within 520 coal burning hours. This document provides a brief description of the Facility and modifications which have been made following the completion of Test Series 2.1. No further modifications were made following the completion of the first part of Test Series 2.3 or Test Series 2.2. The operating requirements for Test Series 2.4 are specified. The tests will be performed using a UK coal (Lady Windsor), and a UK limestone (Middleton) both nominated by the FRG. Seven objectives are proposed which are to be fulfilled by thirteen test conditions. Six part load tests based on input supplied by Kraftwerk Union AG are included. The cascade is expected to be on line for each test condition and total cascade exposure is expected to be in excess of 450 hours. Details of sampling and special measurements are given. A test plan schedule envisages the full test series being completed within a two month calendar period. Finally, a number of contingency strategies are proposed. 3 figures, 14 tables.« less

  13. Delinquency and Peer Acceptance in Adolescence: A Within-Person Test of Moffitt’s Hypotheses

    PubMed Central

    Rulison, Kelly L; Kreager, Derek A.; Osgood, D. Wayne

    2015-01-01

    We tested two hypotheses derived from Moffitt’s (1993) taxonomic theory of antisocial behavior, both of which are central to her explanation for the rise in delinquency during adolescence. Specifically, we tested whether persistently delinquent individuals become more accepted by their peers during adolescence and whether individuals who abstain from delinquent behavior become less accepted. Participants were 4,359 adolescents from 14 communities in the PROSPER study, which assessed friendship networks and delinquency from 6th (M = 11.8 years) to 9th (M = 15.3 years) grade. We operationalized peer acceptance as: number of nominations received (indegree centrality), attractiveness as a friend (adjusted indegree centrality), and network bridging potential (betweenness centrality) and tested the hypotheses using multilevel modeling. Contrary to Moffitt’s hypothesis, persistently delinquent youth did not become more accepted between early and middle adolescence, and although abstainers were less accepted in early adolescence, they became more accepted over time. Results were similar for boys and girls; when differences occurred, they provided no support for Moffitt’s hypotheses for boys and were opposite of her hypotheses for girls. Sensitivity analyses using alternative strategies and additional data to identify persistently delinquent adolescents produced similar results. We explore the implications of these results for Moffitt’s assertions that social mimicry of persistently antisocial adolescents leads to increases in delinquency and that social isolation leads to abstention. PMID:25243328

  14. Process Improvements in Training Device Acceptance Testing: A Study in Total Quality Management

    DTIC Science & Technology

    1990-12-12

    Quality Management , a small group of Government and industry specialists examined the existing training device acceptance test process for potential improvements. The agreed-to mission of the Air Force/Industry partnership was to continuously identify and promote implementable approaches to minimize the cost and time required for acceptance testing while ensuring that validated performance supports the user training requirements. Application of a Total Quality process improvement model focused on the customers and their requirements, analyzed how work was accomplished, and

  15. Current use and acceptability of novel diagnostic tests for active tuberculosis: a worldwide survey

    PubMed Central

    Amicosante, Massimo; D’Ambrosio, Lia; Munoz, Marcela; Mello, Fernanda Carvalho de Queiroz; Tebruegge, Marc; Chegou, Novel Njweipi; Seghrouchni, Fouad; Centis, Rosella; Goletti, Delia; Bothamley, Graham; Migliori, Giovanni Battista

    2017-01-01

    ABSTRACT Objective: To determine the current use and potential acceptance (by tuberculosis experts worldwide) of novel rapid tests for the diagnosis of tuberculosis that are in line with World Health Organization target product profiles. Methods: A multilingual survey was disseminated online between July and November of 2016. Results: A total of 723 individuals from 114 countries responded to the survey. Smear microscopy was the most commonly used rapid tuberculosis test (available to 90.9% of the respondents), followed by molecular assays (available to 70.7%). Only a small proportion of the respondents in middle- and low-income countries had access to interferon-gamma-release assays. Serological and lateral flow immunoassays were used by more than a quarter (25.4%) of the respondents. Among the respondents who had access to molecular tests, 46.7% were using the Xpert assay overall, that proportion being higher in lower middle-income countries (55.6%) and low-income countries (76.6%). The data also suggest that there was some alignment of pricing for molecular assays. Respondents stated they would accept novel rapid tuberculosis tests if available, including molecular assays (acceptable to 86.0%) or biomarker-based serological assays (acceptable to 81.7%). Simple biomarker-based assays were more commonly deemed acceptable in middle- and low-income countries. Conclusions: Second-generation molecular assays have become more widely available in high- and low-resource settings. However, the development of novel rapid tuberculosis tests continues to be considered important by tuberculosis experts. Our data also underscore the need for additional training and education of end users. PMID:29160384

  16. Current use and acceptability of novel diagnostic tests for active tuberculosis: a worldwide survey.

    PubMed

    Amicosante, Massimo; D'Ambrosio, Lia; Munoz, Marcela; Mello, Fernanda Carvalho de Queiroz; Tebruegge, Marc; Chegou, Novel Njweipi; Seghrouchni, Fouad; Centis, Rosella; Goletti, Delia; Bothamley, Graham; Migliori, Giovanni Battista

    2017-01-01

    To determine the current use and potential acceptance (by tuberculosis experts worldwide) of novel rapid tests for the diagnosis of tuberculosis that are in line with World Health Organization target product profiles. A multilingual survey was disseminated online between July and November of 2016. A total of 723 individuals from 114 countries responded to the survey. Smear microscopy was the most commonly used rapid tuberculosis test (available to 90.9% of the respondents), followed by molecular assays (available to 70.7%). Only a small proportion of the respondents in middle- and low-income countries had access to interferon-gamma-release assays. Serological and lateral flow immunoassays were used by more than a quarter (25.4%) of the respondents. Among the respondents who had access to molecular tests, 46.7% were using the Xpert assay overall, that proportion being higher in lower middle-income countries (55.6%) and low-income countries (76.6%). The data also suggest that there was some alignment of pricing for molecular assays. Respondents stated they would accept novel rapid tuberculosis tests if available, including molecular assays (acceptable to 86.0%) or biomarker-based serological assays (acceptable to 81.7%). Simple biomarker-based assays were more commonly deemed acceptable in middle- and low-income countries. Second-generation molecular assays have become more widely available in high- and low-resource settings. However, the development of novel rapid tuberculosis tests continues to be considered important by tuberculosis experts. Our data also underscore the need for additional training and education of end users.

  17. 40 CFR 600.009 - Hearing on acceptance of test data.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Hearing on acceptance of test data. 600.009 Section 600.009 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND GREENHOUSE GAS EXHAUST EMISSIONS OF MOTOR VEHICLES General Provisions § 600.009...

  18. 40 CFR 600.009 - Hearing on acceptance of test data.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Hearing on acceptance of test data. 600.009 Section 600.009 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND GREENHOUSE GAS EXHAUST EMISSIONS OF MOTOR VEHICLES General Provisions § 600.009...

  19. 40 CFR 600.009 - Hearing on acceptance of test data.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Hearing on acceptance of test data. 600.009 Section 600.009 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND GREENHOUSE GAS EXHAUST EMISSIONS OF MOTOR VEHICLES General Provisions § 600.009...

  20. Acceptability of unsupervised HPV self-sampling using written instructions.

    PubMed

    Waller, J; McCaffery, K; Forrest, S; Szarewski, A; Cadman, L; Austin, J; Wardle, J

    2006-01-01

    The study measured the acceptability of self-sampling for human papillomavirus (HPV) testing in the context of cervical cancer screening. Women carried out self-sampling unsupervised, using a written instruction sheet. Participants were women attending either a family planning clinic or a primary care trust for routine cervical screening. Women (n = 902) carried out self-sampling for HPV testing and then a clinician did a routine cervical smear and HPV test. Immediately after having the two tests, participants completed a measure of acceptability for both tests, and answered questions about ease of using the instruction sheet and willingness to use self-sampling in the future. The majority of women found self-sampling more acceptable than the clinician-administered test, but there was a lack of confidence that the test had been done correctly. Significant demographic differences in attitudes were found, with married women having more favourable attitudes towards self-sampling than single women, and Asian women having more negative attitudes than women in other ethnic groups. Intention to use self-sampling in the future was very high across all demographic groups. Self-sampling for HPV testing was highly acceptable in this large and demographically diverse sample, and women were able to carry out the test alone, using simple written instructions. Consistent with previous studies, women were concerned about doing the test properly and this issue will need to be addressed if self-sampling is introduced. More work is needed to see whether the demographic differences we found are robust and to identify reasons for lower acceptability among single women and those from Asian background.

  1. Accelerated test plan for nickel cadmium spacecraft batteries

    NASA Technical Reports Server (NTRS)

    Hennigan, T. J.

    1973-01-01

    An accelerated test matrix is outlined that includes acceptance, baseline and post-cycling tests, chemical and physical analyses, and the data analysis procedures to be used in determining the feasibility of an accelerated test for sealed, nickel cadmium cells.

  2. Test Planning Approach and Lessons

    NASA Technical Reports Server (NTRS)

    Parkinson, Douglas A.; Brown, Kendall K.

    2004-01-01

    As NASA began technology risk reduction activities and planning for the next generation launch vehicle under the Space Launch Initiative (SLI), now the Next Generation Launch Technology (NGLT) Program, a review of past large liquid rocket engine development programs was performed. The intent of the review was to identify any significant lessons from the development testing programs that could be applied to current and future engine development programs. Because the primary prototype engine in design at the time of this study was the Boeing-Rocketdyne RS-84, the study was slightly biased towards LOX/RP-1 liquid propellant engines. However, the significant lessons identified are universal. It is anticipated that these lessons will serve as a reference for test planning in the Engine Systems Group at Marshall Space Flight Center (MSFC). Towards the end of F-1 and J-2 engine development testing, NASA/MSFC asked Rocketdyne to review those test programs. The result was a document titled, Study to Accelerate Development by Test of a Rocket Engine (R-8099). The "intent (of this study) is to apply this thinking and learning to more efficiently develop rocket engines to high reliability with improved cost effectivenes" Additionally, several other engine programs were reviewed - such as SSME, NSTS, STME, MC-1, and RS-83- to support or refute the R-8099. R-8099 revealed two primary lessons for test planning, which were supported by the other engine development programs. First, engine development programs can benefit from arranging the test program for engine system testing as early as feasible. The best test for determining environments is at the system level, the closest to the operational flight environment. Secondly, the component testing, which tends to be elaborate, should instead be geared towards reducing risk to enable system test. Technical risk can be reduced at the component level, but the design can only be truly verified and validated after engine system testing.

  3. Agile Acceptance Test-Driven Development of Clinical Decision Support Advisories: Feasibility of Using Open Source Software.

    PubMed

    Basit, Mujeeb A; Baldwin, Krystal L; Kannan, Vaishnavi; Flahaven, Emily L; Parks, Cassandra J; Ott, Jason M; Willett, Duwayne L

    2018-04-13

    Moving to electronic health records (EHRs) confers substantial benefits but risks unintended consequences. Modern EHRs consist of complex software code with extensive local configurability options, which can introduce defects. Defects in clinical decision support (CDS) tools are surprisingly common. Feasible approaches to prevent and detect defects in EHR configuration, including CDS tools, are needed. In complex software systems, use of test-driven development and automated regression testing promotes reliability. Test-driven development encourages modular, testable design and expanding regression test coverage. Automated regression test suites improve software quality, providing a "safety net" for future software modifications. Each automated acceptance test serves multiple purposes, as requirements (prior to build), acceptance testing (on completion of build), regression testing (once live), and "living" design documentation. Rapid-cycle development or "agile" methods are being successfully applied to CDS development. The agile practice of automated test-driven development is not widely adopted, perhaps because most EHR software code is vendor-developed. However, key CDS advisory configuration design decisions and rules stored in the EHR may prove amenable to automated testing as "executable requirements." We aimed to establish feasibility of acceptance test-driven development of clinical decision support advisories in a commonly used EHR, using an open source automated acceptance testing framework (FitNesse). Acceptance tests were initially constructed as spreadsheet tables to facilitate clinical review. Each table specified one aspect of the CDS advisory's expected behavior. Table contents were then imported into a test suite in FitNesse, which queried the EHR database to automate testing. Tests and corresponding CDS configuration were migrated together from the development environment to production, with tests becoming part of the production regression test

  4. 7 CFR 1207.323 - Acceptance.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE POTATO RESEARCH AND PROMOTION PLAN Potato Research and Promotion Plan National Potato Promotion Board § 1207.323 Acceptance. Each person...

  5. 7 CFR 1207.323 - Acceptance.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE POTATO RESEARCH AND PROMOTION PLAN Potato Research and Promotion Plan National Potato Promotion Board § 1207.323 Acceptance. Each person...

  6. 7 CFR 1207.323 - Acceptance.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE POTATO RESEARCH AND PROMOTION PLAN Potato Research and Promotion Plan National Potato Promotion Board § 1207.323 Acceptance. Each person...

  7. 7 CFR 1207.323 - Acceptance.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE POTATO RESEARCH AND PROMOTION PLAN Potato Research and Promotion Plan National Potato Promotion Board § 1207.323 Acceptance. Each person...

  8. 7 CFR 1207.323 - Acceptance.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE POTATO RESEARCH AND PROMOTION PLAN Potato Research and Promotion Plan National Potato Promotion Board § 1207.323 Acceptance. Each person...

  9. Multiple-sip temporal dominance of sensations associated with acceptance test: a study on special beers.

    PubMed

    Corrêa Simioni, Síntia Carla; Ribeiro, Michele Nayara; de Souza, Vanessa Rios; Nunes, Cleiton Antônio; Pinheiro, Ana Carla Marques

    2018-03-01

    In this study, we proposed the use of a multiple-sip temporal dominance of sensations (TDS) test alongside with an acceptance test over repeated consumption for the analysis of special beers, with the aim of contributing to a deeper understanding of consumer behavior regarding temporal descriptions and sensory acceptance. Consumers of special beers sequentially evaluated six sips of a particular type of beer by TDS analysis and an acceptance test was performed for each sip. Four different kinds of specialty beers were evaluated [Bohemian Pilsner (BP), Witbier (WB), Belgian Strong Ale Dubbel (BD), and Russian Imperial Stout (RS)]. In general, the descriptive profile of beers varied temporally, i.e., there was an increased dominance of bitterness and a decreased dominance of fruity, floral, toffee, and coffee attributes. Concurrently, a reduction in sensory acceptance with an increased number of sips, especially the last sip, was observed in two kinds of beers that possessed a strong flavor, BD and RS. BP and WB presented smooth attributes and low notable characteristics, which could have contributed to the maintenance of the acceptance grades as the number of sips increased. The combination of TDS and acceptance over repeated sips can be useful for obtaining detailed descriptions of products that are closer to real time consumption by consumers, and thus aids in ensuring good product performance once released. The information obtained can also help product development scientists to fine-tune product formulations and ensure acceptability.

  10. Feasibility and acceptability of HIV self-testing among pre-exposure prophylaxis users in Kenya.

    PubMed

    Ngure, Kenneth; Heffron, Renee; Mugo, Nelly; Thomson, Kerry A; Irungu, Elizabeth; Njuguna, Njambi; Mwaniki, Lawrence; Celum, Connie; Baeten, Jared M

    2017-02-10

    HIV testing is key to the delivery of pre-exposure prophylaxis (PrEP): testing HIV-uninfected at-risk persons is the first step for PrEP initiation and ongoing HIV testing is an essential part of PrEP delivery. Thus, novel and cost-effective HIV-testing approaches to streamline delivery of PrEP are urgently needed. Within a demonstration project of PrEP for HIV prevention among high-risk HIV serodiscordant couples in Kenya (the Partners Demonstration Project), we conducted a pilot evaluation of HIV self-testing. Clinic visits were scheduled quarterly and included in-clinic HIV testing using fingerstick rapid HIV tests and refills of PrEP prescriptions. HIV oral fluid self-test kits were provided for participants to use in the two-month interval between scheduled quarterly clinic visits. Acceptability of HIV self-testing was assessed using both quantitative and qualitative methods. We found that 222 of 226 (98%) HIV-uninfected persons who were offered accepted self-testing. Nearly all (96.8%) reported that using the self-testing kit was easy. More than half (54.5%) reportedly did not share the HIV results from self-testing with anyone and almost all (98.7%) the participants did not share the HIV self-testing kits with anyone. Many participants reported that HIV self-testing was empowering and reduced anxiety associated with waiting between clinic HIV tests. HIV self-testing was highly acceptable and may therefore be a feasible strategy to efficiently permit routine HIV testing between PrEP refills.

  11. Energy Systems Test Area (ESTA) Electrical Power Systems Test Operations: User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Salinas, Michael J.

    2012-01-01

    Test process, milestones and inputs are unknowns to first-time users of the ESTA Electrical Power Systems Test Laboratory. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  12. Acceptance of Genetic Testing in a General Population: Age, Education and Gender Differences.

    ERIC Educational Resources Information Center

    Aro, A. R.; Hakonen, A.; Hietala, M.; Lonnqvist, J.; Niemela, P.; Peltonen, L; Aula, P.

    1997-01-01

    Effects of age, education, and gender on acceptance of genetic testing were studied. Finnish participants responded to a questionnaire presenting reasons for and against genetic testing (N=1,967). Intentions to take genetic tests, worries, and experience of genetic test or hereditary disease were also assessed. Results are presented and discussed.…

  13. 46 CFR 159.007-5 - Production inspections and tests: Application for acceptance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Production inspections and tests: Application for acceptance. 159.007-5 Section 159.007-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS Production Inspection and Tests of Approved...

  14. 46 CFR 159.007-5 - Production inspections and tests: Application for acceptance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Production inspections and tests: Application for acceptance. 159.007-5 Section 159.007-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS Production Inspection and Tests of Approved...

  15. Dynamic simulations for preparing the acceptance test of JT-60SA cryogenic system

    NASA Astrophysics Data System (ADS)

    Cirillo, R.; Hoa, C.; Michel, F.; Poncet, J. M.; Rousset, B.

    2016-12-01

    Power generation in the future could be provided by thermo-nuclear fusion reactors like tokamaks. There inside, the fusion reaction takes place thanks to the generation of plasmas at hundreds of millions of degrees that must be confined magnetically with superconductive coils, cooled down to around 4.5 K. Within this frame, an experimental tokamak device, JT-60SA is currently under construction in Naka (Japan). The plasma works cyclically and the coil system is subject to pulsed heat loads. In order to size the refrigerator close to the average power and hence optimizing investment and operational costs, measures have to be taken to smooth the heat load. Here we present a dynamic model of the JT-60SA's Auxiliary Cold box (ACB) for preparing the acceptance tests of the refrigeration system planned in 2016 in Naka. The aim of this study is to simulate the pulsed load scenarios using different process controls. All the simulations have been performed with EcosimPro® and the associated cryogenic library: CRYOLIB.

  16. Acceptance of Routine HIV Testing by Hospitalized Adolescents and Young Adults.

    PubMed

    Bhalakia, Avni M; Talib, Hina J; Choi, Jaeun; Watnick, Dana; Bochner, Risa; Futterman, Donna; Gross, Elissa

    2018-04-01

    Youth carry a disproportionate burden of new HIV infections. With our study, we aimed to characterize HIV testing experiences among adolescents and young adults admitted to a children's hospital that is located in a high HIV-prevalent community and implemented routine HIV testing for all patients ≥13 years of age. A total of 120 patients aged 13 to 24 years old who were admitted to our hospital and had a documented offer of routine HIV testing on admission were invited to complete a self-administered survey that asked about sex, race and/or ethnicity, HIV risk behaviors, and attitudes toward routine HIV testing in the hospital. Date of birth, admission diagnosis, and verification of HIV testing and results were collected by chart review. Study participants ( N = 99) were 17.4 ± 2.3 years old, 52% female, 47% Hispanic, and 29% African American. Additional characteristics include the following: 65% had previous sexual activity, 11% had a history of sexually transmitted infections, and 12% were worried about their risk for HIV. Forty-seven percent of participants accepted HIV testing, with older patients ( P < .01) and those reporting previous sexual activity ( P < .01) and a previous HIV test ( P < .01) being more likely to accept testing. A total of 96% of participants agreed that the hospital is a good place to offer HIV testing. Our findings support offering routine HIV testing to youth admitted to children's hospital. Given the high incidence of new and undiagnosed HIV infections among youth, additional venues for HIV testing are essential. Copyright © 2018 by the American Academy of Pediatrics.

  17. 46 CFR 160.062-8 - Procedures for acceptance of testing facility.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Procedures for acceptance of testing facility. 160.062-8 Section 160.062-8 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Releases. Lifesaving Equipment...

  18. Predictors of HIV-related risk perception and PrEP acceptability among young adult female family planning patients.

    PubMed

    Garfinkel, Danielle B; Alexander, Kamila A; McDonald-Mosley, Reagan; Willie, Tiara C; Decker, Michele R

    2017-06-01

    HIV pre-exposure prophylaxis (PrEP) presents new opportunities for HIV prevention. While women comprise approximately 20% of new HIV infections in the US, significant questions remain about how to most effectively facilitate PrEP uptake for this population. Family planning clinics are a dominant source of health care for young women and support an estimated 4.5 million women annually. We explore characteristics associated with HIV risk perception and PrEP acceptability among young adult women seeking reproductive health services in a high-prevalence setting. A cross-sectional, clinic-based survey was conducted with women ages 18-35 (n = 146) seeking health care at two family planning clinics in the greater Baltimore, Maryland area, from January to April 2014. An estimated 22% of women reported being worried about HIV risk, and 60% reported they would consider taking a pill daily to prevent HIV. In adjusted models, HIV-related worry was associated with having no college education, being single or dating more than one person, practicing consistent condom use during vaginal sex, and having ever traded sex. PrEP acceptability was significantly associated with being Black (71% vs. 49%, AOR 2.23, CI: 1.89-2.64) and having ever traded sex (83% vs. 58%, AOR 4.94, CI: 2.00-12.22). For women with a history of intimate partner violence (IPV), PrEP acceptability was significantly lower (57% vs. 62%, AOR .71, CI: .59-.85) relative to their non-abused counterparts. Results suggest that family planning clinics may be a natural setting for PrEP discussion and roll-out. They should be considered in the context of integrating HIV prevention with reproductive health services. Women with a trauma history may need additional support for implementing HIV prevention in the form of PrEP.

  19. Advanced Materials Laboratory User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Orndoff, Evelyne

    2012-01-01

    Test process, milestones and inputs are unknowns to first-time users of the Advanced Materials Laboratory. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  20. 241-AZ-101 Waste Tank Color Video Camera System Shop Acceptance Test Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    WERRY, S.M.

    2000-03-23

    This report includes shop acceptance test results. The test was performed prior to installation at tank AZ-101. Both the camera system and camera purge system were originally sought and procured as a part of initial waste retrieval project W-151.

  1. Crawler Acquisition and Testing Demonstration Project Management Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DEFIGH-PRICE, C.

    2000-10-23

    If the crawler based retrieval system is selected, this project management plan identifies the path forward for acquiring a crawler/track pump waste retrieval system, and completing sufficient testing to support deploying the crawler for as part of a retrieval technology demonstration for Tank 241-C-104. In the balance of the document, these activities will be referred to as the Crawler Acquisition and Testing Demonstration. During recent Tri-Party Agreement negotiations, TPA milestones were proposed for a sludge/hard heel waste retrieval demonstration in tank C-104. Specifically one of the proposed milestones requires completion of a cold demonstration of sufficient scale to support finalmore » design and testing of the equipment (M-45-03G) by 6/30/2004. A crawler-based retrieval system was one of the two options evaluated during the pre-conceptual engineering for C-104 retrieval (RPP-6843 Rev. 0). The alternative technology procurement initiated by the Hanford Tanks Initiative (HTI) project, combined with the pre-conceptual engineering for C-104 retrieval provide an opportunity to achieve compliance with the proposed TPA milestone M-45-03H. This Crawler Acquisition and Testing Demonstration project management plan identifies the plans, organizational interfaces and responsibilities, management control systems, reporting systems, timeline and requirements for the acquisition and testing of the crawler based retrieval system. This project management plan is complimentary to and supportive of the Project Management Plan for Retrieval of C-104 (RPP-6557). This project management plan focuses on utilizing and completing the efforts initiated under the Hanford Tanks Initiative (HTI) to acquire and cold test a commercial crawler based retrieval system. The crawler-based retrieval system will be purchased on a schedule to support design of the waste retrieval from tank C-104 (project W-523) and to meet the requirement of proposed TPA milestone M-45-03H. This Crawler

  2. Propulsion Ground Testing: Planning for the Future

    NASA Technical Reports Server (NTRS)

    Bruce, Robert

    2003-01-01

    Advanced planners are constantly being asked to plan for the provision of future test capability. Historically, this capability is provided either by substantial investment in new test facility capabilities, or in the substantial investment in the modification of pre- existing test capabilities. The key words in the previous sentence are "substantial investment". In the evolving environment of increasingly constrained resources, how is an advanced planner to plan for the provisions of such capabilities? Additionally, the conundrum exists that program formulation decisions are being made based upon both life cycle cost decisions in an environment in which the more immediate challenge of "front-end" capital investment? Often times is the linch-pin upon which early decisions are made. In such an environment, how are plans and decisions made? This paper cites examples of decisions made in the past in the area of both major test facility upgrades, as well as major new test facility investment.

  3. Propulsion Ground Testing: Planning for the Future

    NASA Technical Reports Server (NTRS)

    Bruce, Robert

    2003-01-01

    Advanced planners are constantly being asked to plan for the provision of future test capability. Historically, this capability is provided either by substantial investment in new test facility capabilities, or in the substantial investment in the modification of pre-exiting test facilities. The key words in the previous sentence are 'substantial investment.' In the evolving environment of increasingly constrained resources, how is an advanced planner to plan for the provisions of such capabilities? Additionally, the conundrum exists that program formulation decisions are being made based on both life cycle cost decisions in an environment in which the more immediate challenge of front-end capital investment oftentimes is the linchpin upon which early decisions are made. In such an environment, how are plans and decisions made? This paper cites examples of decisions made in the past in the area of both major test facility upgrades, as well as major new test facility investment.

  4. Rein tension acceptance in young horses in a voluntary test situation.

    PubMed

    Christensen, J W; Zharkikh, T L; Antoine, A; Malmkvist, J

    2011-03-01

    During riding, horses are frequently exposed to pressure from the rider, e.g. through the bit and reins, but few studies have investigated at which point rein tension becomes uncomfortable for the horse. To investigate how much rein tension young inexperienced horses are willing to accept in order to obtain a food reward; whether the tension acceptance changes during 3 consecutive test days; and whether rein tension correlates with the expression of conflict behaviour and heart rate. Pressure-naïve horses will apply only little rein tension in the first voluntary trial, but their acceptance will gradually increase. High levels of rein tension will lead to expression of conflict behaviour and increases in heart rate. Fifteen 2-year-old, bridle-naïve mares were encouraged to stretch their head forward (across a 0.95 m high metal bar) to obtain a food reward in a voluntary test situation. On each test day, each horse was exposed to 2 control sessions (loose reins), an intermediate and a short rein session (1 min/session). Rein tension, heart rate and behaviour were recorded. The horses applied significantly more tension on the first day (mean rein tension: 10.2 N), compared to the second and third test day (Day 2: 6.0 and Day 3: 5.7 N). The horses showed significantly more conflict behaviour in the short rein treatment. There was no treatment effect on heart rate. The horses applied the highest rein tension on the first day, and apparently learned to avoid the tension, rather than habituate to it. Rein tension correlated with expression of conflict behaviour, indicating that the horses found the tension aversive. Further studies should focus on the correlation between rein tension and conflict behaviour in ridden horses. © 2010 EVJ Ltd.

  5. 46 CFR 164.013-5 - Acceptance tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... described in UL 1191, as appropriate, are performed on a minimum of five samples in each of the lightest and darkest colors submitted for acceptance by a recognized laboratory accepted under § 164.019. ...

  6. 46 CFR 164.013-5 - Acceptance tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... described in UL 1191, as appropriate, are performed on a minimum of five samples in each of the lightest and darkest colors submitted for acceptance by a recognized laboratory accepted under § 164.019. ...

  7. 46 CFR 164.013-5 - Acceptance tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... described in UL 1191, as appropriate, are performed on a minimum of five samples in each of the lightest and darkest colors submitted for acceptance by a recognized laboratory accepted under § 164.019. ...

  8. A Multi-Year Plan for Research, Development, and Prototype Testing of Standard Modular Hydropower Technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Brennan T.; Welch, Tim; Witt, Adam M.

    The Multi-Year Plan for Research, Development, and Prototype Testing of Standard Modular Hydropower Technology (MYRP) presents a strategy for specifying, designing, testing, and demonstrating the efficacy of standard modular hydropower (SMH) as an environmentally compatible and cost-optimized renewable electricity generation technology. The MYRP provides the context, background, and vision for testing the SMH hypothesis: if standardization, modularity, and preservation of stream functionality become essential and fully realized features of hydropower technology, project design, and regulatory processes, they will enable previously unrealized levels of new project development with increased acceptance, reduced costs, increased predictability of outcomes, and increased value to stakeholders.more » To achieve success in this effort, the MYRP outlines a framework of stakeholder-validated criteria, models, design tools, testing facilities, and assessment protocols that will facilitate the development of next-generation hydropower technologies.« less

  9. A modern space simulation facility to accommodate high production acceptance testing

    NASA Technical Reports Server (NTRS)

    Glover, J. D.

    1986-01-01

    A space simulation laboratory that supports acceptance testing of spacecraft and associated subsystems at throughput rates as high as nine per year is discussed. The laboratory includes a computer operated 27' by 30' space simulation, a 20' by 20' by 20' thermal cycle chamber and an eight station thermal cycle/thermal vacuum test system. The design philosophy and unique features of each system are discussed. The development of operating procedures, test team requirements, test team integration, and other peripheral activation details are described. A discussion of special accommodations for the efficient utilization of the systems in support of high rate production is presented.

  10. Evaluating outcomes of computer-based classroom testing: Student acceptance and impact on learning and exam performance.

    PubMed

    Zheng, Meixun; Bender, Daniel

    2018-03-13

    Computer-based testing (CBT) has made progress in health sciences education. In 2015, the authors led implementation of a CBT system (ExamSoft) at a dental school in the U.S. Guided by the Technology Acceptance Model (TAM), the purposes of this study were to (a) examine dental students' acceptance of ExamSoft; (b) understand factors impacting acceptance; and (c) evaluate the impact of ExamSoft on students' learning and exam performance. Survey and focus group data revealed that ExamSoft was well accepted by students as a testing tool and acknowledged by most for its potential to support learning. Regression analyses showed that perceived ease of use and perceived usefulness of ExamSoft significantly predicted student acceptance. Prior CBT experience and computer skills did not significantly predict acceptance of ExamSoft. Students reported that ExamSoft promoted learning in the first program year, primarily through timely and rich feedback on examination performance. t-Tests yielded mixed results on whether students performed better on computerized or paper examinations. The study contributes to the literature on CBT and the application of the TAM model in health sciences education. Findings also suggest ways in which health sciences institutions can implement CBT to maximize its potential as an assessment and learning tool.

  11. High Acceptability of HIV Self-Testing among Technical Vocational Education and Training College Students in Gauteng and North West Province: What Are the Implications for the Scale Up in South Africa?

    PubMed

    Mokgatle, Mathildah Mpata; Madiba, Sphiwe

    2017-01-01

    Although HIV self-testing (HIVST) is globally accepted as an important complement to existing HIV testing approaches, South Africa has lagged behind in its adoption. As a result, data on the acceptability and uptake of HIVST testing is limited. The study investigated the acceptability of HIVST among students in Technical Vocational Education and Training (TVET) colleges in two provinces in South Africa. A cross-sectional survey using a self-administered structured questionnaire was used to collect data among 3,662 students recruited from 13 TVET colleges. The mean age of the students was 21.9 years. The majority (80.9%) were sexually active; while 66.1% reported that they had one sexual partner, and 33.9% had two or more sexual partners in the past year, and66.5% used condoms during the last sexual act. Three-quarters tested for HIV in the past year but less than half knew about HIVST prior to the survey. The acceptability of HIVST was high; about three-quarters showed a willingness to purchase a self-test kit and a majority would self-test with partners. Acceptability of HIVST was associated with being sexually active (OR = 1.73, p = 0.02, confidence interval (CI): 1.08-2.75), having ever been tested for HIV (OR = 1.74, p = 0.001, CI: 1.26-2.38), and having multiple sexual partners (OR = 0.61, p = 0.01, CI: 0.42-0.88). Three-quarters would confirm test results at a local health facility. In terms of counselling, telephone hotlines were acceptable to only 39.9%, and less than half felt that test-kit leaflets would provide sufficient information to self-test. The high acceptability of HIVST among the students calls for extensive planning and preparation for the scaling up of HIVST in South Africa. In addition, campaigns similar to those conducted to promote HIV counselling and testing (HCT) should be considered to educate communities about HIVST.

  12. High Acceptability of HIV Self-Testing among Technical Vocational Education and Training College Students in Gauteng and North West Province: What Are the Implications for the Scale Up in South Africa?

    PubMed Central

    Mokgatle, Mathildah Mpata; Madiba, Sphiwe

    2017-01-01

    Background Although HIV self-testing (HIVST) is globally accepted as an important complement to existing HIV testing approaches, South Africa has lagged behind in its adoption. As a result, data on the acceptability and uptake of HIVST testing is limited. The study investigated the acceptability of HIVST among students in Technical Vocational Education and Training (TVET) colleges in two provinces in South Africa. Methods A cross-sectional survey using a self-administered structured questionnaire was used to collect data among 3,662 students recruited from 13 TVET colleges. Results The mean age of the students was 21.9 years. The majority (80.9%) were sexually active; while 66.1% reported that they had one sexual partner, and 33.9% had two or more sexual partners in the past year, and66.5% used condoms during the last sexual act. Three-quarters tested for HIV in the past year but less than half knew about HIVST prior to the survey. The acceptability of HIVST was high; about three-quarters showed a willingness to purchase a self-test kit and a majority would self-test with partners. Acceptability of HIVST was associated with being sexually active (OR = 1.73, p = 0.02, confidence interval (CI): 1.08–2.75), having ever been tested for HIV (OR = 1.74, p = 0.001, CI: 1.26–2.38), and having multiple sexual partners (OR = 0.61, p = 0.01, CI: 0.42–0.88). Three-quarters would confirm test results at a local health facility. In terms of counselling, telephone hotlines were acceptable to only 39.9%, and less than half felt that test-kit leaflets would provide sufficient information to self-test. Interpretations The high acceptability of HIVST among the students calls for extensive planning and preparation for the scaling up of HIVST in South Africa. In addition, campaigns similar to those conducted to promote HIV counselling and testing (HCT) should be considered to educate communities about HIVST. PMID:28141858

  13. Six-Degree-of-Freedom Dynamic Test System (SDTS) User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Stokes, LeBarian

    2012-01-01

    Test process, milestones and inputs are unknowns to first-time users of the SDTS. The User Test Planning Guide aids in establishing expectations for both NASA and non- NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  14. Test Plan: WIPP bin-scale CH TRU waste tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Molecke, M.A.

    1990-08-01

    This WIPP Bin-Scale CH TRU Waste Test program described herein will provide relevant composition and kinetic rate data on gas generation and consumption resulting from TRU waste degradation, as impacted by synergistic interactions due to multiple degradation modes, waste form preparation, long-term repository environmental effects, engineered barrier materials, and, possibly, engineered modifications to be developed. Similar data on waste-brine leachate compositions and potentially hazardous volatile organic compounds released by the wastes will also be provided. The quantitative data output from these tests and associated technical expertise are required by the WIPP Performance Assessment (PA) program studies, and for the scientificmore » benefit of the overall WIPP project. This Test Plan describes the necessary scientific and technical aspects, justifications, and rational for successfully initiating and conducting the WIPP Bin-Scale CH TRU Waste Test program. This Test Plan is the controlling scientific design definition and overall requirements document for this WIPP in situ test, as defined by Sandia National Laboratories (SNL), scientific advisor to the US Department of Energy, WIPP Project Office (DOE/WPO). 55 refs., 16 figs., 19 tabs.« less

  15. Space Suit Portable Life Support System (PLSS) 2.0 Pre-Installation Acceptance (PIA) Testing

    NASA Technical Reports Server (NTRS)

    Anchondo, Ian; Cox, Marlon; Meginnis, Carly; Westheimer, David; Vogel, Matt R.

    2016-01-01

    Following successful completion of the space suit Portable Life Support System (PLSS) 1.0 development and testing in 2011, the second system-level prototype, PLSS 2.0, was developed in 2012 to continue the maturation of the advanced PLSS design. This advanced PLSS is intended to reduce consumables, improve reliability and robustness, and incorporate additional sensing and functional capabilities over the current Space Shuttle/International Space Station Extravehicular Mobility Unit (EMU) PLSS. PLSS 2.0 represents the first attempt at a packaged design comprising first generation or later component prototypes and medium fidelity interfaces within a flight-like representative volume. Pre-Installation Acceptance (PIA) is carryover terminology from the Space Shuttle Program referring to the series of test sequences used to verify functionality of the EMU PLSS prior to installation into the Space Shuttle airlock for launch. As applied to the PLSS 2.0 development and testing effort, PIA testing designated the series of 27 independent test sequences devised to verify component and subsystem functionality, perform in situ instrument calibrations, generate mapping data, define set-points, evaluate control algorithms, evaluate hardware performance against advanced PLSS design requirements, and provide quantitative and qualitative feedback on evolving design requirements and performance specifications. PLSS 2.0 PIA testing was carried out in 2013 and 2014 using a variety of test configurations to perform test sequences that ranged from stand-alone component testing to system-level testing, with evaluations becoming increasingly integrated as the test series progressed. Each of the 27 test sequences was vetted independently, with verification of basic functionality required before completion. Because PLSS 2.0 design requirements were evolving concurrently with PLSS 2.0 PIA testing, the requirements were used as guidelines to assess performance during the tests; after the

  16. Space Suit Portable Life Support System (PLSS) 2.0 Pre-Installation Acceptance (PIA) Testing

    NASA Technical Reports Server (NTRS)

    Watts, Carly; Vogel, Matthew

    2016-01-01

    Following successful completion of the space suit Portable Life Support System (PLSS) 1.0 development and testing in 2011, the second system-level prototype, PLSS 2.0, was developed in 2012 to continue the maturation of the advanced PLSS design which is intended to reduce consumables, improve reliability and robustness, and incorporate additional sensing and functional capabilities over the current Space Shuttle/International Space Station Extravehicular Mobility Unit (EMU) PLSS. PLSS 2.0 represents the first attempt at a packaged design comprising first generation or later component prototypes and medium fidelity interfaces within a flight-like representative volume. Pre-Installation Acceptance (PIA) is carryover terminology from the Space Shuttle Program referring to the series of test sequences used to verify functionality of the EMU PLSS prior to installation into the Space Shuttle airlock for launch. As applied to the PLSS 2.0 development and testing effort, PIA testing designated the series of 27 independent test sequences devised to verify component and subsystem functionality, perform in situ instrument calibrations, generate mapping data to define set-points for control algorithms, evaluate hardware performance against advanced PLSS design requirements, and provide quantitative and qualitative feedback on evolving design requirements and performance specifications. PLSS 2.0 PIA testing was carried out from 3/20/13 - 3/15/14 using a variety of test configurations to perform test sequences that ranged from stand-alone component testing to system-level testing, with evaluations becoming increasingly integrated as the test series progressed. Each of the 27 test sequences was vetted independently, with verification of basic functionality required before completion. Because PLSS 2.0 design requirements were evolving concurrently with PLSS 2.0 PIA testing, the requirements were used as guidelines to assess performance during the tests; after the completion of PIA

  17. Physics of Colloids in Space--Plus (PCS+) Experiment Completed Flight Acceptance Testing

    NASA Technical Reports Server (NTRS)

    Doherty, Michael P.

    2004-01-01

    The Physics of Colloids in Space--Plus (PCS+) experiment successfully completed system-level flight acceptance testing in the fall of 2003. This testing included electromagnetic interference (EMI) testing, vibration testing, and thermal testing. PCS+, an Expedite the Process of Experiments to Space Station (EXPRESS) Rack payload will deploy a second set of colloid samples within the PCS flight hardware system that flew on the International Space Station (ISS) from April 2001 to June 2002. PCS+ is slated to return to the ISS in late 2004 or early 2005.

  18. Using Optimization to Improve Test Planning

    DTIC Science & Technology

    2017-09-01

    friendly and to display the output differently, the test and evaluation test schedule optimization model would be a good tool for the test and... evaluation schedulers. 14. SUBJECT TERMS schedule optimization, test planning 15. NUMBER OF PAGES 223 16. PRICE CODE 17. SECURITY CLASSIFICATION OF...make the input more user-friendly and to display the output differently, the test and evaluation test schedule optimization model would be a good tool

  19. Mod-2 wind turbine project assessment and cluster test plans

    NASA Technical Reports Server (NTRS)

    Gordon, L. H.

    1982-01-01

    An assessment of the Mod-2 Wind Turbine project is presented based on initial goals and present results. Specifically, the Mod-2 background, project flow, and a chronology of events/results leading to Mod-2 acceptance is presented. After checkout/acceptance of the three operating turbines, NASA/LeRC will continue management of a two year test program performed at the DOE Goodnoe Hills test site. This test program is expected to yield data necessary for the continued development and optimization of wind energy systems. These test activities, the implementation of, and the results to date are also presented.

  20. Acceptance test procedure for the L-070 project mechanical equipment and instrumentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loll, C.M.

    1996-04-19

    This document contains the acceptance test procedure for the mechanical equipment and instrumentation installed per the L-070 Project. The specific system to be tested are the pump controls for the 3906 Lift Station and 350-A Lift Station. In addition, verification that signals are being received by the 300 Area Treated Effluent Disposal Facility control system, is also performed.

  1. 40 CFR Appendix Xv to Part 86 - Procedure for Determining an Acceptable Exhaust Regeneration Durability-Data Test Schedule for...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Acceptable Exhaust Regeneration Durability-Data Test Schedule for Diesel Cycle Vehicles Equipped With... Appendix XV to Part 86—Procedure for Determining an Acceptable Exhaust Regeneration Durability-Data Test... = Total number of regeneration emission tests. (Subscript “s” refers to standard test schedule) 5. Refer...

  2. 40 CFR Appendix Xv to Part 86 - Procedure for Determining an Acceptable Exhaust Regeneration Durability-Data Test Schedule for...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Acceptable Exhaust Regeneration Durability-Data Test Schedule for Diesel Cycle Vehicles Equipped With... Appendix XV to Part 86—Procedure for Determining an Acceptable Exhaust Regeneration Durability-Data Test... = Total number of regeneration emission tests. (Subscript “s” refers to standard test schedule) 5. Refer...

  3. 40 CFR Appendix Xv to Part 86 - Procedure for Determining an Acceptable Exhaust Regeneration Durability-Data Test Schedule for...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Acceptable Exhaust Regeneration Durability-Data Test Schedule for Diesel Cycle Vehicles Equipped With... Appendix XV to Part 86—Procedure for Determining an Acceptable Exhaust Regeneration Durability-Data Test... = Total number of regeneration emission tests. (Subscript “s” refers to standard test schedule) 5. Refer...

  4. Delinquency and Peer Acceptance in Adolescence: A Within-Person Test of Moffitt's Hypotheses

    ERIC Educational Resources Information Center

    Rulison, Kelly L.; Kreager, Derek A.; Osgood, D. Wayne

    2014-01-01

    We tested 2 hypotheses derived from Moffitt's (1993) taxonomic theory of antisocial behavior, both of which are central to her explanation for the rise in delinquency during adolescence. We tested whether persistently delinquent individuals become more accepted by their peers during adolescence and whether individuals who abstain from delinquent…

  5. Planned Comparisons as Better Alternatives to ANOVA Omnibus Tests.

    ERIC Educational Resources Information Center

    Benton, Roberta L.

    Analyses of data are presented to illustrate the advantages of using a priori or planned comparisons rather than omnibus analysis of variance (ANOVA) tests followed by post hoc or posteriori testing. The two types of planned comparisons considered are planned orthogonal non-trend coding contrasts and orthogonal polynomial or trend contrast coding.…

  6. The deformable secondary mirror of VLT: final electro-mechanical and optical acceptance test results

    NASA Astrophysics Data System (ADS)

    Briguglio, Runa; Biasi, Roberto; Xompero, Marco; Riccardi, Armando; Andrighettoni, Mario; Pescoller, Dietrich; Angerer, Gerald; Gallieni, Daniele; Vernet, Elise; Kolb, Johann; Arsenault, Robin; Madec, Pierre-Yves

    2014-07-01

    The Deformable Secondary Mirror (DSM) for the VLT ended the stand-alone electro-mechanical and optical acceptance process, entering the test phase as part of the Adaptive Optics Facility (AOF) at the ESO Headquarter (Garching). The VLT-DSM currently represents the most advanced already-built large-format deformable mirror with its 1170 voice-coil actuators and its internal metrology based on co-located capacitive sensors to control the shape of the 1.12m-diameter 2mm-thick convex shell. The present paper reports the final results of the electro-mechanical and optical characterization of the DSM executed in a collaborative effort by the DSM manufacturing companies (Microgate s.r.l. and A.D.S. International s.r.l.), INAF-Osservatorio Astrofisico di Arcetri and ESO. The electro-mechanical acceptance tests have been performed in the company premises and their main purpose was the dynamical characterization of the internal control loop response and the calibration of the system data that are needed for its optimization. The optical acceptance tests have been performed at ESO (Garching) using the ASSIST optical test facility. The main purpose of the tests are the characterization of the optical shell flattening residuals, the corresponding calibration of flattening commands, the optical calibration of the capacitive sensors and the optical calibration of the mirror influence functions.

  7. MCC/shuttle test plan. Volume 1: Philosophy and guidelines

    NASA Technical Reports Server (NTRS)

    1976-01-01

    The Mission Control Center/Shuttle Test Plan is defined from development through operations to a level of detail which will support the National Aeronautics and Space Administration and contractor management in the following areas: test management, test tool development, and resource and schedule planning.

  8. Test Plan - Solids Accumulation Scouting Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duignan, M. R.; Steeper, T. J.; Steimke, J. L.

    This plan documents the highlights of the Solids Accumulations Scouting Studies test; a project, from Washington River Protection Solutions (WRPS), that began on February 1, 2012. During the last 12 weeks considerable progress has been made to design and plan methods that will be used to estimate the concentration and distribution of heavy fissile solids in accumulated solids in the Hanford double-shell tank (DST) 241-AW-105 (AW-105), which is the primary goal of this task. This DST will be one of the several waste feed delivery staging tanks designated to feed the Pretreatment Facility (PTF) of the Waste Treatment and Immobilizationmore » Plant (WTP). Note that over the length of the waste feed delivery mission AW-105 is currently identified as having the most fill empty cycles of any DST feed tanks, which is the reason for modeling this particular tank. At SRNL an existing test facility, the Mixing Demonstration Tank, which will be modified for the present work, will use stainless steel particles in a simulant that represents Hanford waste to perform mock staging tanks transfers that will allow solids to accumulate in the tank heel. The concentration and location of the mock fissile particles will be measured in these scoping studies to produce information that will be used to better plan larger scaled tests. Included in these studies is a secondary goal of developing measurement methods to accomplish the primary goal. These methods will be evaluated for use in the larger scale experiments. Included in this plan are the several pretest activities that will validate the measurement techniques that are currently in various phases of construction. Aspects of each technique, e.g., particle separations, volume determinations, topographical mapping, and core sampling, have been tested in bench-top trials, as discussed herein, but the actual equipment to be employed during the full test will need evaluation after fabrication and integration into the test facility.« less

  9. Acceptance Testing of the Vapor Phase Catalytic Ammonia Removal Engineering Development Unit

    NASA Technical Reports Server (NTRS)

    Flynn, Michael; Fisher, John; Kliss, Mark; Tleimat, Maher; Quinn, Gregory; Fort, James; Nalette, Tim; Baker, Gale

    2005-01-01

    This paper describes the results of acceptance testing of the Vapor Phase Catalytic Ammonia Removal (VPCAR) technology. The VPCAR technology is currently being developed by NASA as a Mars transit vehicle water recycling system. NASA has recently completed a grant to develop a next generation VPCAR system. This grant was peer reviewed and funded through the Advanced Life Support (ALS) National Research Announcement (NRA). The grant funded a contract with Water Reuse Technology Inc. to construct an engineering development unit. This contract concluded with the shipment of the final deliverable to NASA on 8/31/03. The objective of the acceptance testing was to characterize the performance of this new system. This paper presents the results of mass power, and volume measurements for the delivered system. In addition, product water purity analysis for a Mars transit mission and a planetary base wastewater ersatz are provided. Acoustic noise levels, interface specifications and system reliability results are also discussed. An assessment of the readiness of the technology for human testing and recommendations for future improvements are provided.

  10. Nurses' perceptions, acceptance, and use of a novel in-room pediatric ICU technology: testing an expanded technology acceptance model.

    PubMed

    Holden, Richard J; Asan, Onur; Wozniak, Erica M; Flynn, Kathryn E; Scanlon, Matthew C

    2016-11-15

    The value of health information technology (IT) ultimately depends on end users accepting and appropriately using it for patient care. This study examined pediatric intensive care unit nurses' perceptions, acceptance, and use of a novel health IT, the Large Customizable Interactive Monitor. An expanded technology acceptance model was tested by applying stepwise linear regression to data from a standardized survey of 167 nurses. Nurses reported low-moderate ratings of the novel IT's ease of use and low to very low ratings of usefulness, social influence, and training. Perceived ease of use, usefulness for patient/family involvement, and usefulness for care delivery were associated with system satisfaction (R 2  = 70%). Perceived usefulness for care delivery and patient/family social influence were associated with intention to use the system (R 2  = 65%). Satisfaction and intention were associated with actual system use (R 2  = 51%). The findings have implications for research, design, implementation, and policies for nursing informatics, particularly novel nursing IT. Several changes are recommended to improve the design and implementation of the studied IT.

  11. Photographic copy of site plan for proposed Test Stand "D" ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photographic copy of site plan for proposed Test Stand "D" in 1958. The contemporary site plans of test stands "A," "B," and "C" are also visible, along with the interconnecting tunnel system. California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering "Site Plan for Proposed Test Stand "D" - Edwards Test Station," drawing no. ESP/22-0, 14 November 1958 - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  12. Acceptability of rapid oral fluid HIV testing among male injection drug users in Taiwan, 1997 and 2007.

    PubMed

    Lyu, Shu-Yu; Morisky, Donald E; Yeh, Ching-Ying; Twu, Shiing-Jer; Peng, Eugene Yu-Chang; Malow, Robert M

    2011-04-01

    Rapid oral fluid HIV testing (rapid oral testing) is in the process of being adapted in Taiwan and elsewhere given its advantages over prior HIV testing methods. To guide this process, we examined the acceptability of rapid oral testing at two time points (i.e., 1997 and 2007) among one of the highest risk populations, male injection drug users (IDUs). For this purpose, an anonymous self-administered survey was completed by HIV-negative IDUs involved in the criminal justice system in 1997 (N (1)=137 parolees) and 2007 (N (2)=106 prisoners). A social marketing model helped guide the design of our questionnaire to assess the acceptability of rapid oral testing. This included assessing a new product, across four marketing dimensions: product, price, promotion, and place. Results revealed that in both 1997 and 2007, over 90% indicated that rapid oral testing would be highly acceptable, particularly if the cost was under US$6, and that a pharmacy would be the most appropriate and accessible venue for selling the rapid oral testing kits. The vast majority of survey respondents believed that the cost of rapid oral testing should be federally subsidized and that television and newspaper advertisements would be the most effective media to advertise for rapid oral testing. Both the 1997 and 2007 surveys suggested that rapid oral HIV testing would be particularly accepted in Taiwan by IDUs after release from the criminal justice system.

  13. Audio Development Laboratory (ADL) User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Romero, Andy

    2012-01-01

    Test process, milestones and inputs are unknowns to first-time users of the ADL. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  14. Department of Defense picture archiving and communication system acceptance testing: results and identification of problem components.

    PubMed

    Allison, Scott A; Sweet, Clifford F; Beall, Douglas P; Lewis, Thomas E; Monroe, Thomas

    2005-09-01

    The PACS implementation process is complicated requiring a tremendous amount of time, resources, and planning. The Department of Defense (DOD) has significant experience in developing and refining PACS acceptance testing (AT) protocols that assure contract compliance, clinical safety, and functionality. The DOD's AT experience under the initial Medical Diagnostic Imaging Support System contract led to the current Digital Imaging Network-Picture Archiving and Communications Systems (DIN-PACS) contract AT protocol. To identify the most common system and component deficiencies under the current DIN-PACS AT protocol, 14 tri-service sites were evaluated during 1998-2000. Sixteen system deficiency citations with 154 separate types of limitations were noted with problems involving the workstation, interfaces, and the Radiology Information System comprising more than 50% of the citations. Larger PACS deployments were associated with a higher number of deficiencies. The most commonly cited systems deficiencies were among the most expensive components of the PACS.

  15. Factors of Online Learning Adoption: A Comparative Juxtaposition of the Theory of Planned Behaviour and the Technology Acceptance Model

    ERIC Educational Resources Information Center

    Ndubisi, Nelson

    2006-01-01

    Organisational investments in information technologies have increased significantly in the past few decades. All around the globe and in Malaysia particularly, a number of educational institutions are experimenting with e-learning. Adopting the theory of planned behaviour (TPB) and the technology acceptance model (TAM) this article tries to…

  16. Closure Plan for the Area 5 Radioactive Waste Management Site at the Nevada Test Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Management

    The Area 5 Radioactive Waste Management Site (RMWS) at the Nevada Test Site (NTS) is managed and operated by National Security Technologies, LLC (NSTec), for the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO). This document is the first update of the preliminary closure plan for the Area 5 RWMS at the NTS that was presented in the Integrated Closure and Monitoring Plan (DOE, 2005a). The major updates to the plan include a new closure schedule, updated closure inventory, updated site and facility characterization data, the Title II engineering cover design, and the closure processmore » for the 92-Acre Area of the RWMS. The format and content of this site-specific plan follows the Format and Content Guide for U.S. Department of Energy Low-Level Waste Disposal Facility Closure Plans (DOE, 1999a). This interim closure plan meets closure and post-closure monitoring requirements of the order DOE O 435.1, manual DOE M 435.1-1, Title 40 Code of Federal Regulations (CFR) Part 191, 40 CFR 265, Nevada Administrative Code (NAC) 444.743, and Resource Conservation and Recovery Act (RCRA) requirements as incorporated into NAC 444.8632. The Area 5 RWMS accepts primarily packaged low-level waste (LLW), low-level mixed waste (LLMW), and asbestiform low-level waste (ALLW) for disposal in excavated disposal cells.« less

  17. 78 FR 65007 - Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 3

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-30

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 052-00026; NRC-2008-0252] Inspections, Tests, Analyses... Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria completion. SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) staff has determined that the inspections, tests...

  18. Proof of concept test plan.

    DOT National Transportation Integrated Search

    2008-06-05

    This document is the Proof of Concept (POC) Test Plan and procedures that will be used : to verify that hardware and application functionality meet the requirements of the U.S. : Department of Transportation (USDOT) Next Generation 9-1-1 Initiative (...

  19. 78 FR 53484 - Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 4

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-29

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 052-00026; NRC-2008-0252] Inspections, Tests, Analyses... Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria (ITAAC) completion. SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) staff has determined that the inspections, tests...

  20. 78 FR 53483 - Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 3

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-29

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 052-00025; NRC-2008-0252] Inspections, Tests, Analyses... Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria (ITAAC) completion. SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) staff has determined that the inspections, tests...

  1. The role of traditional organization on family planning acceptance in Indonesia.

    PubMed

    Ancok, D

    1991-01-01

    The nature of and the reasons for the decline in Indonesian fertility and the utilization of the village traditional organization, banjar, in the family planning (FP) program are discussed. The total fertility rate computed from census data shows a decline in fertility from 5.6 in the mid-1960s to 4.1 for 1981-1984, a 28% decline in 15 years. A further 23% decline evidenced in the Contraceptive Prevalence Survey appeared as 4.3 children reproductive woman in 1981-83 and 3.3 between 1984-87. The success of the FP program in contributing a major impact on the decline is attributed to a strong political commitment to antinatalist policy which meant increased allocation to FP when government income was declining, effective organizational structure, and effective strategies such as the mobilization of traditional village organizations. The impact of FP can also be seen in the increase in the number of family acceptors. Another source of the fertility decline is due to the impact of development. 1) Improvement in education has contributed to fertility decline in the increase in the number graduating from elementary and secondary school, the increased value of children, the acceptance of new ideas, the postponement of marriage, and the increase in the never-married group. 2) The decline in the infant mortality rate from 142 in 1971 to 70.2/1000 births in 1982-87 due to the improvement in health facilities and service also contributed to fertility decline. 3) The growth in the number of women participating in the nonagricultural labor force has also contributed to fertility decline. To what extent each has contributed to the decline has not been empirically tested. Molyneaux' study is cited for demonstrating that both socioeconomic variables and contraceptive use, which are affected by socioeconomic variables and family planning, have influenced the fertility decline. Households with electricity, children engaged in the labor force, and frequency of mobile medical team

  2. Avionics test bed development plan

    NASA Technical Reports Server (NTRS)

    Harris, L. H.; Parks, J. M.; Murdock, C. R.

    1981-01-01

    A development plan for a proposed avionics test bed facility for the early investigation and evaluation of new concepts for the control of large space structures, orbiter attached flex body experiments, and orbiter enhancements is presented. A distributed data processing facility that utilizes the current laboratory resources for the test bed development is outlined. Future studies required for implementation, the management system for project control, and the baseline system configuration are defined. A background analysis of the specific hardware system for the preliminary baseline avionics test bed system is included.

  3. 48 CFR 611.103 - Market acceptance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Market acceptance. 611.103 Section 611.103 Federal Acquisition Regulations System DEPARTMENT OF STATE COMPETITION AND ACQUISITION PLANNING DESCRIBING AGENCY NEEDS Selecting and Developing Requirements Documents 611.103 Market acceptance...

  4. Vibroacoustic test plan evaluation: Parameter variation study

    NASA Technical Reports Server (NTRS)

    Stahle, C. V.; Gongloef, H. R.

    1976-01-01

    Statistical decision models are shown to provide a viable method of evaluating the cost effectiveness of alternate vibroacoustic test plans and the associated test levels. The methodology developed provides a major step toward the development of a realistic tool to quantitatively tailor test programs to specific payloads. Testing is considered at the no test, component, subassembly, or system level of assembly. Component redundancy and partial loss of flight data are considered. Most and probabilistic costs are considered, and incipient failures resulting from ground tests are treated. Optimums defining both component and assembly test levels are indicated for the modified test plans considered. modeling simplifications must be considered in interpreting the results relative to a particular payload. New parameters introduced were a no test option, flight by flight failure probabilities, and a cost to design components for higher vibration requirements. Parameters varied were the shuttle payload bay internal acoustic environment, the STS launch cost, the component retest/repair cost, and the amount of redundancy in the housekeeping section of the payload reliability model.

  5. Space telescope observatory management system preliminary test and verification plan

    NASA Technical Reports Server (NTRS)

    Fritz, J. S.; Kaldenbach, C. F.; Williams, W. B.

    1982-01-01

    The preliminary plan for the Space Telescope Observatory Management System Test and Verification (TAV) is provided. Methodology, test scenarios, test plans and procedure formats, schedules, and the TAV organization are included. Supporting information is provided.

  6. 10 CFR 26.91 - Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use. 26.91 Section 26.91 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.91 Acceptable devices for conducting initial...

  7. 10 CFR 26.91 - Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use. 26.91 Section 26.91 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.91 Acceptable devices for conducting initial...

  8. 10 CFR 26.91 - Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use. 26.91 Section 26.91 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.91 Acceptable devices for conducting initial...

  9. 10 CFR 26.91 - Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use. 26.91 Section 26.91 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.91 Acceptable devices for conducting initial...

  10. 10 CFR 26.91 - Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use. 26.91 Section 26.91 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.91 Acceptable devices for conducting initial...

  11. Report on the Acceptance Test of the CRI Y-MP 8128, 10 February - 12 March 1990

    NASA Technical Reports Server (NTRS)

    Carter, Russell; Kutler, Paul (Technical Monitor)

    1998-01-01

    The NAS Numerical Aerodynamic Simulation Facility's HSP 2 computer system, a CRI Y-MP 832 SN #1002, underwent a major hardware upgrade in February of 1990. The 32 MWord, 6.3 ns mainframe component of the system was replaced with a 128 MWord, 6.0 ns CRI Y-MP 8128 mainframe, SN #1030. A 30 day Acceptance Test of the computer system was performed by the NAS RND HSP group from 08:00 February 10, 1990 to 08:00 March 12, 1990. Overall responsibility for the RND HSP Acceptance Test was assumed by Duane Carbon. The terms of the contract required that the SN #1030 achieve an effectiveness level of greater than or equal to ninety (90) percent for 30 consecutive days within a 60 day time frame. After the first thirty days, the effectiveness level of SN #1030 was 94.4 percent, hence the acceptance test was passed.

  12. Integrating Telemedicine for Disaster Response: Testing the Emergency Telemedicine Technology Acceptance Model

    ERIC Educational Resources Information Center

    Davis, Theresa M.

    2013-01-01

    Background: There is little evidence that technology acceptance is well understood in healthcare. The hospital environment is complex and dynamic creating a challenge when new technology is introduced because it impacts current processes and workflows which can significantly affect patient care delivery and outcomes. This study tested the effect…

  13. SU-F-P-37: Implementation of An End-To-End QA Test of the Radiation Therapy Imaging, Planning and Delivery Process to Identify and Correct Possible Sources of Deviation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salinas Aranda, F; Suarez, V; Arbiser, S

    2016-06-15

    Purpose: To implement an end-to-end QA test of the radiation therapy imaging, planning and delivery process, aimed to assess the dosimetric agreement accuracy between planned and delivered treatment, in order to identify and correct possible sources of deviation. To establish an internal standard for machine commissioning acceptance. Methods: A test involving all steps of the radiation therapy: imaging, planning and delivery process was designed. The test includes analysis of point dose and planar dose distributions agreement between TPS calculated and measured dose. An ad hoc 16 cm diameter PMMA phantom was constructed with one central and four peripheral bores thatmore » can accommodate calibrated electron density inserts. Using Varian Eclipse 10.0 and Elekta XiO 4.50 planning systems, IMRT, RapidArc and 3DCRT with hard and dynamic wedges plans were planned on the phantom and tested. An Exradin A1SL chamber is used with a Keithley 35617EBS electrometer for point dose measurements in the phantom. 2D dose distributions were acquired using MapCheck and Varian aS1000 EPID.Gamma analysis was performed for evaluation of 2D dose distribution agreement using MapCheck software and Varian Portal Dosimetry Application.Varian high energy Clinacs Trilogy, 2100C/CD, 2000CR and low energy 6X/EX where tested.TPS-CT# vs. electron density table were checked for CT-scanners used. Results: Calculated point doses were accurate to 0.127% SD: 0.93%, 0.507% SD: 0.82%, 0.246% SD: 1.39% and 0.012% SD: 0.01% for LoX-3DCRT, HiX-3DCRT, IMRT and RapidArc plans respectively. Planar doses pass gamma 3% 3mm in all cases and 2% 2mm for VMAT plans. Conclusion: Implementation of a simple and reliable quality assurance tool was accomplished. The end-to-end proved efficient, showing excellent agreement between planned and delivered dose evidencing strong consistency of the whole process from imaging through planning to delivery. This test can be used as a first step in beam model acceptance for

  14. Acceptability of Sexually Transmitted Infection Testing Using Self-Collected Vaginal Swabs among College Women

    ERIC Educational Resources Information Center

    Fielder, Robyn L.; Carey, Kate B.; Carey, Michael P.

    2013-01-01

    Objective: To assess the acceptability of sexually transmitted infection (STI) testing using self-collected vaginal swabs (SCVS) among college women. Participants: First-year female students ("N" = 483). Methods: Participants were offered free testing for 3 STIs using SCVS in April 2010 and later completed a survey regarding their…

  15. In search of acceptable alternatives to the murine histamine sensitisation test (HIST): what is possible and practical?

    PubMed

    Wagner, L; Isbrucker, R; Locht, C; Arciniega, J; Costanzo, A; McFarland, R; Oh, H; Hoonakker, M; Descamps, J; Andersen, S R; Gupta, R K; Markey, K; Chapsal, J M; Lidster, K; Casey, W; Allen, D

    2016-01-01

    The 'International Workshop on Alternatives to the Murine Histamine Sensitization Test for Acellular Pertussis Vaccines: In Search of Acceptable Alternatives to the Murine Histamine Sensitization Test (HIST): What is Possible and Practical?' was held on 4 and 5 March 2015 in London, United Kingdom. Participants discussed the results of the data generated from an international collaborative study (BSP114 Phase 2) sponsored by the European Directorate for the Quality of Medicines & Health Care (EDQM) to determine if a modified Chinese hamster ovary (CHO) cell-based clustering assay is a suitable alternative to replace HIST. Workshop participants agreed that protocol transferability demonstrated in the collaborative study indicates that a standardised CHO cell assay is adequate for measuring pure PTx in reference preparations. However, vaccine manufacturers would still need to demonstrate that the method is valid to detect or measure residual PTx in their specific adjuvanted products. The 2 modified CHO cell protocols included in the study (the Direct and the Indirect Methods) deserve further consideration as alternatives to HIST. Using the CHO cell assay, an in vitro alternative, for acellular pertussis (aP) vaccine batch release testing would reduce the number of animals used for aP vaccine safety testing. A strategic, stepwise adoption plan was proposed, in which the alternative test would be used for release purposes first, and then, once sufficient confidence in its suitable performance has been gained, its use would be extended to stability testing.

  16. Project Plan: Salt in Situ Heater Test.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuhlman, Kristopher L.; Mills, Melissa Marie; Herrick, Courtney G.

    This project plan gives a high-level description of the US Department of Energy Office of Nuclear Energy (DOE-NE) Spent Fuel and Waste Disposition (SFWD) campaign in situ borehole heater test project being planned for the Waste Isolation Pilot Plant (WIPP) site This plan provides an overview of the schedule and responsibilities of the parties involved. This project is a collaborative effort by Sandia, Los Alamos, and Lawrence Berkeley National Laboratories to execute a series of small-diameter borehole heater tests in salt for the DOE-NE SFWD campaign. Design of a heater test in salt at WIPP has evolved over several years.more » The current design was completed in fiscal year 2017 (FY17), an equipment shakedown experiment is underway in April FY18, and the test implementation will begin in summer of FY18. The project comprises a suite of modular tests, which consist of a group of nearby boreholes in the wall of drifts at WIPP. Each test is centered around a packer-isolated heated borehole (5" diameter) containing equipment for water-vapor collection and brine sampling, surrounded by smaller-diameter (2" diameter) satellite observation boreholes. Observation boreholes will contain temperature sensors, tracer release points, electrical resistivity tomography (ERT) sensors, fiber optic sensing, and acoustic emission (AE) measurements, and sonic velocity sources and sensors. These satellite boreholes will also be used for plugging/sealing tests. The first two tests to be implemented will have the packer-isolated borehole heated to 120°C, with one observation borehole used to monitor changes. Follow-on tests will be designed using information gathered from the first two tests, will be conducted at other temperatures, will use multiple observation boreholes, and may include other measurement types and test designs.« less

  17. Validation and testing of the Acceptability E-scale for Web-based patient-reported outcomes in cancer care

    PubMed Central

    Tariman, Joseph D.; Berry, Donna L.; Halpenny, Barbara; Wolpin, Seth; Schepp, Karen

    2010-01-01

    The performance of the Acceptability E-scale was tested in a sample of 627 adult and older adult patients from various oncology clinics who completed an electronic symptoms survey. The revised Acceptability E-scale has strong psychometric properties and can be useful in assessing the acceptability and usability of computerized health-related programs in oncology and other health population. PMID:20974066

  18. Who accepts a rapid HIV antibody test? The role of race/ethnicity and HIV risk behavior among community adolescents.

    PubMed

    Swenson, Rebecca R; Hadley, Wendy S; Houck, Christopher D; Dance, S Kwame; Brown, Larry K

    2011-05-01

    Centers for Disease Control and Prevention guidelines recommend routine human immunodeficiency virus (HIV) screening in health care settings for all individuals aged 13-64 years; however, overall testing rates among adolescents still continue to remain low. This study examined factors related to the acceptance of HIV testing among an at-risk sample of ethnically/racially diverse community adolescents. Adolescents aged 15-21 (N = 81) years were recruited from community-based youth organizations to complete HIV risk assessment surveys. After the completion of the survey, participants were offered a free OraQuick rapid HIV antibody test. More than half (53.1%) of the participants accepted the test, with the black population being more likely to accept testing as compared to Latinos (75% vs. 39%). After controlling for race/ethnicity, significant predictors of test acceptance included history of sexual intercourse (OR = 5.43), having only one sexual partner in the past 3 months (OR = 4.88), not always using a condom with a serious partner (OR = 3.94), and not using a condom during last sexual encounter (OR = 4.75). Given that many adolescents are willing to know their HIV status, policies that support free or low-cost routine testing may lead to higher rates of case identification among youth. However, approaches must be developed to increase test acceptance among Latino adolescents and teenagers with multiple sexual partners. Copyright © 2011 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  19. The Theory of Planned Behavior (TPB) and Pre-Service Teachers' Technology Acceptance: A Validation Study Using Structural Equation Modeling

    ERIC Educational Resources Information Center

    Teo, Timothy; Tan, Lynde

    2012-01-01

    This study applies the theory of planned behavior (TPB), a theory that is commonly used in commercial settings, to the educational context to explain pre-service teachers' technology acceptance. It is also interested in examining its validity when used for this purpose. It has found evidence that the TPB is a valid model to explain pre-service…

  20. Acceptability of using electronic vending machines to deliver oral rapid HIV self-testing kits: a qualitative study.

    PubMed

    Young, Sean D; Daniels, Joseph; Chiu, ChingChe J; Bolan, Robert K; Flynn, Risa P; Kwok, Justin; Klausner, Jeffrey D

    2014-01-01

    Rates of unrecognized HIV infection are significantly higher among Latino and Black men who have sex with men (MSM). Policy makers have proposed that HIV self-testing kits and new methods for delivering self-testing could improve testing uptake among minority MSM. This study sought to conduct qualitative assessments with MSM of color to determine the acceptability of using electronic vending machines to dispense HIV self-testing kits. African American and Latino MSM were recruited using a participant pool from an existing HIV prevention trial on Facebook. If participants expressed interest in using a vending machine to receive an HIV self-testing kit, they were emailed a 4-digit personal identification number (PIN) code to retrieve the test from the machine. We followed up with those who had tested to assess their willingness to participate in an interview about their experience. Twelve kits were dispensed and 8 interviews were conducted. In general, participants expressed that the vending machine was an acceptable HIV test delivery method due to its novelty and convenience. Acceptability of this delivery model for HIV testing kits was closely associated with three main factors: credibility, confidentiality, and convenience. Future research is needed to address issues, such as user-induced errors and costs, before scaling up the dispensing method.

  1. Acceptability and Feasibility of HIV Self-Testing Among Transgender Women in San Francisco: A Mixed Methods Pilot Study.

    PubMed

    Lippman, Sheri A; Moran, Lissa; Sevelius, Jae; Castillo, Leslie S; Ventura, Angel; Treves-Kagan, Sarah; Buchbinder, Susan

    2016-04-01

    An estimated one in four transgender women (trans women) in the U.S. are infected with HIV. Rates of HIV testing are not commensurate with their risk, necessitating alternative strategies for early detection and care. We explored the feasibility and acceptability of HIV self-testing (HIVST) with 50 HIV-negative adult trans women in San Francisco. Participants received three self-test kits to perform once a month. Acceptability and behavioral surveys were collected as were 11 in-depth interviews (IDIs). Among 50 participants, 44 reported utilizing HIVST at least once; 94 % reported the test easy to use; 93 % said results were easy to read; and 91 % would recommend it to others. Most participants (68 %) preferred HIVST to clinic-based testing, although price was a key barrier to uptake. IDIs revealed a tension between desires for privacy versus support found at testing sites. HIVST for trans women was acceptable and feasible and requires careful consideration of linkage to support services.

  2. Acceptability and feasibility of HIV self-testing among men who have sex with men in Peru and Brazil

    PubMed Central

    Volk, Jonathan E; Lippman, Sheri A; Grinsztejn, Beatriz; Lama, Javier R; Fernandes, Nilo M; Gonzales, Pedro; Hessol, Nancy A; Buchbinder, Susan

    2015-01-01

    HIV self-testing has the potential to increase testing frequency and uptake. This pilot study assessed the feasibility and acceptability of HIV self-testing in a sample of sexually active men who have sex with men in Peru and Brazil. Participants were trained to use a whole blood rapid HIV self-test and instructed to use the self-test monthly during this three-month study. Test acceptability was measured with self-reported use of the test at the one-month and three-month study visits, and test feasibility was assessed by direct observation of self-test administration at the final three-month visit. A total of 103 participants (52 in Peru and 51 in Brazil) were enrolled, and 86% completed the three-month study. Nearly all participants reported use of the self-test (97% at one-month and 98% at three-month visit), and all participants correctly interpreted the self-administered test results when observed using the test at the final study visit. HIV self-testing with a blood-based assay was highly acceptable and feasible. HIV self-testing may have the potential to increase testing frequency and to reach high-risk men who have sex with men not currently accessing HIV-testing services. PMID:25971262

  3. Acceptability and feasibility of HIV self-testing among men who have sex with men in Peru and Brazil.

    PubMed

    Volk, Jonathan E; Lippman, Sheri A; Grinsztejn, Beatriz; Lama, Javier R; Fernandes, Nilo M; Gonzales, Pedro; Hessol, Nancy A; Buchbinder, Susan

    2016-06-01

    HIV self-testing has the potential to increase testing frequency and uptake. This pilot study assessed the feasibility and acceptability of HIV self-testing in a sample of sexually active men who have sex with men (MSM) in Peru and Brazil. Participants were trained to use a whole blood rapid HIV self-test and instructed to use the self-test monthly during this three-month study. Test acceptability was measured with self-reported use of the test at the one-month and three-month study visits, and test feasibility was assessed by direct observation of self-test administration at the final three-month visit. A total of 103 participants (52 in Peru and 51 in Brazil) were enrolled, and 86% completed the three-month study. Nearly all participants reported use of the self-test (97% at one-month and 98% at three-month visit), and all participants correctly interpreted the self-administered test results when observed using the test at the final study visit. HIV self-testing with a blood-based assay was highly acceptable and feasible. HIV self-testing may have the potential to increase testing frequency and to reach high-risk MSM not currently accessing HIV-testing services. © The Author(s) 2015.

  4. 48 CFR 411.103 - Market acceptance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Market acceptance. 411.103... ACQUISITION PLANNING DESCRIBING AGENCY NEEDS Selecting and Developing Requirements Documents 411.103 Market... accordance with FAR 11.103(a), the market acceptability of their items to be offered. (b) The contracting...

  5. [Acceptability of HIV testing provided to infants in pediatric services in Cote d'Ivoire, meanings for pediatric diagnostic coverage].

    PubMed

    Oga, Maxime; Brou, Hermann; Dago-Akribi, Hortense; Coffie, Patrick; Amani-Bossé, Clarisse; Ekouévi, Didier; Yapo, Vincent; Menan, Hervé; Ndondoki, Camille; Timité-Konan, M; Leroy, Valériane

    2014-01-01

    HIV testing in children had rarely been a central concern for researchers. When pediatric tracking retained the attention, it was more to inform on the diagnosis tools' performances rather than the fact the pediatric test can be accepted or refused. This article highlights the parents' reasons which explain why pediatric HIV test is accepted or refused. To study among parents, the explanatory factors of the acceptability of pediatric HIV testing among infant less than six months. Semi-structured interview with repeated passages in the parents of infants less than six months attending in health care facilities for the pediatric weighing/vaccination and consultations. We highlight that the parents' acceptance of the pediatric HIV screening is based on three elements. Firstly, the health care workers by his speech (which indicates its own knowledge and perceptions on the infection) directed towards mothers' influences their acceptance or not of the HIV test. Secondly, the mother who by her knowledge and perceptions on HIV, whose particular status, give an impression of her own wellbeing for her and her child influences any acceptance of the pediatric HIV test. Thirdly, the marital environment of the mother, particularly characterized by the ease of communication within the couple, to speak about the HIV test and its realization for the parents or the mother only are many factors which influence the effective realization of the pediatric HIV testing. The preventive principle of HIV transmission and the desire to realize the test in the newborn are not enough alone to lead to its effective realization, according to certain mothers confronted with the father's refusal. On the other hand, the other mothers refusing the realization of the pediatric test told to be opposed to it; of course, even if their partner would accept it. The mothers are the principal facing the pediatric HIV question and fear the reprimands and stigma. The father, the partner could be an obstacle

  6. SU-F-T-475: An Evaluation of the Overlap Between the Acceptance Testing and Commissioning Processes for Conventional Medical Linear Accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morrow, A; Rangaraj, D; Perez-Andujar, A

    2016-06-15

    Purpose: This work’s objective is to determine the overlap of processes, in terms of sub-processes and time, between acceptance testing and commissioning of a conventional medical linear accelerator and to evaluate the time saved by consolidating the two processes. Method: A process map for acceptance testing for medical linear accelerators was created from vendor documentation (Varian and Elekta). Using AAPM TG-106 and inhouse commissioning procedures, a process map was created for commissioning of said accelerators. The time to complete each sub-process in each process map was evaluated. Redundancies in the processes were found and the time spent on each weremore » calculated. Results: Mechanical testing significantly overlaps between the two processes - redundant work here amounts to 9.5 hours. Many beam non-scanning dosimetry tests overlap resulting in another 6 hours of overlap. Beam scanning overlaps somewhat - acceptance tests include evaluating PDDs and multiple profiles but for only one field size while commissioning beam scanning includes multiple field sizes and depths of profiles. This overlap results in another 6 hours of rework. Absolute dosimetry, field outputs, and end to end tests are not done at all in acceptance testing. Finally, all imaging tests done in acceptance are repeated in commissioning, resulting in about 8 hours of rework. The total time overlap between the two processes is about 30 hours. Conclusion: The process mapping done in this study shows that there are no tests done in acceptance testing that are not also recommended to do for commissioning. This results in about 30 hours of redundant work when preparing a conventional linear accelerator for clinical use. Considering these findings in the context of the 5000 linacs in the United states, consolidating acceptance testing and commissioning would have allowed for the treatment of an additional 25000 patients using no additional resources.« less

  7. Test Series 2. 2: Detailed Test Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Test Series 2.2 comprises the third sub-series of tests to be scheduled as a part of Test Series 2, the second stage of the combustion research program to be carried out at the Grimethorpe Experimental Pressurized Fluidized Bed Combustion Facility. Test Series 2.1, the first sub-series of tests, was completed in February 1983, and the first half of the second sub-series, Test Series 2.3, in October 1983. Test Series 2.2 is to consist of 350 data gathering hours, which it is hoped to complete within 560 coal burning hours. This document provides a brief description of the Facility and modificationsmore » which have been made following the completion of Test Series 2.1. No further modifications were made following the completion of the first half of Test Series 2.3. The operating requirements are specified. The tests will be performed using a UK coal (Kiveton Park), and a UK limestone (Middleton) both nominated by the FRG. Nine objectives are proposed which are to be fulfilled by thirteen test conditions. Six part load tests are included, as defined by Kraftwerk Union AG. The cascade is expected to be on line for each test condition and total cascade exposure is expected to be in excess of 450 hours. Details of sampling and special measurements are given. A test plan schedule envisages the test series being completed within a two month calendar period. Finally, a number of contingency strategies are proposed.« less

  8. Chamber B Thermal/Vacuum Chamber: User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Montz, Mike E.

    2012-01-01

    Test process, milestones and inputs are unknowns to first-time users of Chamber B. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  9. Electromagnetic Interference/Compatibility (EMI/EMC) Control Test and Measurement Facility: User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Scully, Robert C.

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the EMI/EMC Test Facility. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  10. Enterprise Architecture Planning in developing A planning Information System: a Case Study of Semarang State University

    NASA Astrophysics Data System (ADS)

    Budiman, Kholiq; Prahasto, Toni; Kusumawardhani, Amie

    2018-02-01

    This research has applied an integrated design and development of planning information system, which is been designed using Enterprise Architecture Planning. Frequent discrepancy between planning and realization of the budget that has been made, resulted in ineffective planning, is one of the reason for doing this research. The design using EAP aims to keep development aligned and in line with the strategic direction of the organization. In the practice, EAP is carried out in several stages of the planning initiation, identification and definition of business functions, proceeded with architectural design and EA implementation plan that has been built. In addition to the design of the Enterprise Architecture, this research carried out the implementation, and was tested by several methods of black box and white box. Black box testing method is used to test the fundamental aspects of the software, tested by two kinds of testing, first is using User Acceptance Testing and the second is using software functionality testing. White box testing method is used to test the effectiveness of the code in the software, tested using unit testing. Tests conducted using white box and black box on the integrated planning information system, is declared successful. Success in the software testing can not be ascertained if the software built has not shown any distinction from prior circumstance to the development of this integrated planning information system. For ensuring the success of this system implementation, the authors test consistency between the planning of data and the realization of prior-use of the information system, until after-use information system. This consistency test is done by reducing the time data of the planning and realization time. From the tabulated data, the planning information system that has been built reduces the difference between the planning time and the realization time, in which indicates that the planning information system can motivate the

  11. Factors associated with acceptance of provider-initiated HIV testing and counseling among pregnant women in Ethiopia.

    PubMed

    Gebremedhin, Ketema Bizuwork; Tian, Bingjie; Tang, Chulei; Zhang, Xiaoxia; Yisma, Engida; Wang, Honghong

    2018-01-01

    The global human immunodeficiency virus (HIV) epidemic disproportionately affects sub-Saharan African countries, including Ethiopia. Provider-initiated HIV testing and counseling (PITC) is a tool to identify HIV-positive pregnant women and an effective treatment and prevention strategy. However, its success depends upon the willingness of pregnant women to accept HIV testing. To describe the level of acceptance of PITC and associated factors among pregnant women attending 8 antenatal care clinics in Adama, Ethiopia. Trained nursing students and employees from an HIV clinic conducted face-to-face structured interviews in private offices at the clinics from August to September, 2016. Among the 441 respondents, 309 (70.1%) accepted PITC. Women with more antenatal care visits (odds ratio [OR] =2.59, 95% CI: 1.01-6.63), reported better quality of the PITC service (OR =1.91, 95% CI: 1.19-3.08), and higher level of knowledge on mother-to-child transmission (OR =1.82, 95% CI: 1.03-3.20), were more likely to accept PITC, while women who were older in age (OR =0.37, 95% CI: 0.19-0.74) and perceived negative attitudes from their partners toward HIV-positive results (OR =0.31, 95% CI: 0.10-0.94) were less likely to accept the PITC service. About one-third of pregnant women are not willing to accept PITC. When designing intervention program to improve the acceptance of PITC, we should take into consideration the personal factors, HIV-related knowledge, and attitude of women as well as institutional factors.

  12. Acceptability of Using Electronic Vending Machines to Deliver Oral Rapid HIV Self-Testing Kits: A Qualitative Study

    PubMed Central

    Young, Sean D.; Daniels, Joseph; Chiu, ChingChe J.; Bolan, Robert K.; Flynn, Risa P.; Kwok, Justin; Klausner, Jeffrey D.

    2014-01-01

    Introduction Rates of unrecognized HIV infection are significantly higher among Latino and Black men who have sex with men (MSM). Policy makers have proposed that HIV self-testing kits and new methods for delivering self-testing could improve testing uptake among minority MSM. This study sought to conduct qualitative assessments with MSM of color to determine the acceptability of using electronic vending machines to dispense HIV self-testing kits. Materials and Methods African American and Latino MSM were recruited using a participant pool from an existing HIV prevention trial on Facebook. If participants expressed interest in using a vending machine to receive an HIV self-testing kit, they were emailed a 4-digit personal identification number (PIN) code to retrieve the test from the machine. We followed up with those who had tested to assess their willingness to participate in an interview about their experience. Results Twelve kits were dispensed and 8 interviews were conducted. In general, participants expressed that the vending machine was an acceptable HIV test delivery method due to its novelty and convenience. Discussion Acceptability of this delivery model for HIV testing kits was closely associated with three main factors: credibility, confidentiality, and convenience. Future research is needed to address issues, such as user-induced errors and costs, before scaling up the dispensing method. PMID:25076208

  13. The role of physician characteristics in clinical trial acceptance: testing pathways of influence.

    PubMed

    Curbow, Barbara; Fogarty, Linda A; McDonnell, Karen A; Chill, Julia; Scott, Lisa Benz

    2006-03-01

    Eight videotaped vignettes were developed that assessed the effects of three physician-related experimental variables (in a 2 x 2 x 2 factorial design) on clinical trial (CT) knowledge, video knowledge, information processing, CT beliefs, affective evaluations (attitudes), and CT acceptance. It was hypothesized that the physician variables (community versus academic-based affiliation, enthusiastic versus neutral presentation of the trial, and new versus previous relationship with the patient) would serve as communication cues that would interrupt message processing, leading to lower knowledge gain but more positive beliefs, attitudes, and CT acceptance. A total of 262 women (161 survivors and 101 controls) participated in the study. The manipulated variables primarily influenced the intermediary variables of post-test CT beliefs and satisfaction with information rather than knowledge or information processing. Multiple regression results indicated that CT acceptance was associated with positive post-CT beliefs, a lower level of information processing, satisfaction with information, and control status. Based on these results, CT acceptance does not appear to be based on a rational decision-making model; this has implications for both the ethics of informed consent and research conceptual models.

  14. Acceptability of Rapid Diagnostic Test-Based Management of Malaria among Caregivers of Under-Five Children in Rural Ghana

    PubMed Central

    Baiden, Frank; Owusu-Agyei, Seth; Okyere, Eunice; Tivura, Mathilda; Adjei, George; Chandramohan, Daniel; Webster, Jayne

    2012-01-01

    Introduction WHO now recommends test-based management of malaria (TBMM) across all age-groups. This implies artemisinin-based combination treatment (ACT) should be restricted to rapid diagnostic test (RDT)-positive cases. This is a departure from what caregivers in rural communities have been used to for many years. Methods We conducted a survey among caregivers living close to 32 health centres in six districts in rural Ghana and used logistic regression to explore factors likely to influence caregiver acceptability of RDT based case management and concern about the denial of ACT on account of negative RDT results. Focus group discussions were conducted to explain the quantitative findings and to elicit further factors. Results A total of 3047 caregivers were interviewed. Nearly all (98%) reported a preference for TBMM over presumptive treatment. Caregivers who preferred TBMM were less likely to be concerned about the denial of ACT to their test-negative children (O.R. 0.57, 95%C.I. 0.33–0.98). Compared with caregivers who had never secured national health insurance cover, caregivers who had valid (adjusted O.R. 1.30, 95% CI 1.07–1.61) or expired (adjusted O.R. 1.38, 95% CI 1.12–1.73) insurance cover were more likely to be concerned about the denial of ACT to their RDT-negative children. Major factors that promote TBMM acceptability include the perception that a blood test at health centre level represents improvement in the quality of care, leads to improvement in treatment outcomes, and offers opportunity for better communication between health workers and caregivers. Acceptability is also enhanced by engaging caregivers in the procedures of the test. Apprehensions about negative health worker attitude could however undermine acceptance. Conclusion Test (RDT)-based management of malaria in under-five children is likely to be acceptable to caregivers in rural Ghana. The quality of caregiver-health worker interaction needs to be improved if acceptability is

  15. Acceptability of rapid diagnostic test-based management of Malaria among caregivers of under-five children in rural Ghana.

    PubMed

    Baiden, Frank; Owusu-Agyei, Seth; Okyere, Eunice; Tivura, Mathilda; Adjei, George; Chandramohan, Daniel; Webster, Jayne

    2012-01-01

    WHO now recommends test-based management of malaria (TBMM) across all age-groups. This implies artemisinin-based combination treatment (ACT) should be restricted to rapid diagnostic test (RDT)-positive cases. This is a departure from what caregivers in rural communities have been used to for many years. We conducted a survey among caregivers living close to 32 health centres in six districts in rural Ghana and used logistic regression to explore factors likely to influence caregiver acceptability of RDT based case management and concern about the denial of ACT on account of negative RDT results. Focus group discussions were conducted to explain the quantitative findings and to elicit further factors. A total of 3047 caregivers were interviewed. Nearly all (98%) reported a preference for TBMM over presumptive treatment. Caregivers who preferred TBMM were less likely to be concerned about the denial of ACT to their test-negative children (O.R. 0.57, 95%C.I. 0.33-0.98). Compared with caregivers who had never secured national health insurance cover, caregivers who had valid (adjusted O.R. 1.30, 95% CI 1.07-1.61) or expired (adjusted O.R. 1.38, 95% CI 1.12-1.73) insurance cover were more likely to be concerned about the denial of ACT to their RDT-negative children. Major factors that promote TBMM acceptability include the perception that a blood test at health centre level represents improvement in the quality of care, leads to improvement in treatment outcomes, and offers opportunity for better communication between health workers and caregivers. Acceptability is also enhanced by engaging caregivers in the procedures of the test. Apprehensions about negative health worker attitude could however undermine acceptance. Test (RDT)-based management of malaria in under-five children is likely to be acceptable to caregivers in rural Ghana. The quality of caregiver-health worker interaction needs to be improved if acceptability is to be sustained.

  16. Short Lesson Plan Associated with Increased Acceptance of Evolutionary Theory and Potential Change in Three Alternate Conceptions of Macroevolution in Undergraduate Students

    ERIC Educational Resources Information Center

    Abraham, Joel K.; Perez, Kathryn E.; Downey, Nicholas; Herron, Jon C.; Meir, Eli

    2012-01-01

    Undergraduates commonly harbor alternate conceptions about evolutionary biology; these alternate conceptions often persist, even after intensive instruction, and may influence acceptance of evolution. We interviewed undergraduates to explore their alternate conceptions about macroevolutionary patterns and designed a 2-h lesson plan to present…

  17. The General Mission Analysis Tool (GMAT) System Test Plan

    NASA Technical Reports Server (NTRS)

    Conway, Darrel J.; Hughes, Steven P.

    2007-01-01

    This document serves as the System Test Approach for the GMAT Project. Preparation for system testing consists of three major stages: 1) The Test Approach sets the scope of system testing, the overall strategy to be adopted, the activities to be completed, the general resources required and the methods and processes to be used to test the release. It also details the activities, dependencies and effort required to conduct the System Test. 2) Test Planning details the activities, dependencies and effort required to conduct the System Test. 3) Test Cases documents the tests to be applied, the data to be processed, the automated testing coverage and the expected results. This document covers the first two of these items, and established the framework used for the GMAT test case development. The test cases themselves exist as separate components, and are managed outside of and concurrently with this System Test Plan.

  18. Kiel sensors for the EPD instrument on-board Solar Orbiter - An overview of the qualification and acceptance test campaigns in phase D

    NASA Astrophysics Data System (ADS)

    Ravanbakhsh, A.; Kulkarni, S. R.; Panitzsch, L.; L Richards, M.; Munoz Hernandez, A.; Seimetz, L.; Elftmann, R.; Mahesh, Y.; Boden, S.; Boettcher, S. I.; Kulemzin, A.; Martin-Garcia, C.; Prieto, M.; Rodriguez-Pacheco, J.; Sanchez Prieto, S.; Schuster, B.; Steinhagen, J.; Tammen, J.; Wimmer-Schweingruber, R. F.

    2016-12-01

    Solar Orbiter is ESA's next solar and heliospheric mission which is planned to be launched in October 2018. The Energetic Particle Detector (EPD) on board on Solar Orbiter will provide key measurements for the Solar Orbiter science objectives. The EPD suite consists of four sensors; STEP, SIS, EPT and HET. The University of Kiel in Germany is responsible for the design, development, and building of STEP, and the two identical units EPT-HET 1 and EPT-HET 2. ESA's Solar Orbiter will explore the heliosphere at heliocentric distances between 0.28AU and 0.9AU and with inclination up to 38deg with respect to the Sun's equator. The spacecraft uses a heat shield to protect the bus and externally mounted instruments from the solar flux at the close distances to the sun. All three EPD-Kiel units are mounted externally but in different positions on the spacecraft outer deck. Although being protected by the spacecraft heat shield from high solar flux, EPT-HET1 and EPT-HET-2 as well as STEP experience a harsh environmental condition during the course of the mission. In addition due to the highly demanding science requirements, the qualification and acceptance test requirements of these externally mounted units are quite challenging. In this paper we present the development status of the EPT-HET 1, EPT-HET 2 and STEP sensors focusing on the activities performed in phase D and the qualification and acceptance test campaigns. The main objective of these test campaigns is to ensure and demonstrate the compatibility between the scientific requirements and the harsh environment expected during the mission. This paper includes the results summary of the environmental tests on the EPT-HET and STEP Proto-Qualification Models (PQMs) as well as Proto-Flight Models (PFMs). Only an adequate selection of environmental qualification and acceptance campaigns will guarantee the success of the scientific space missions.

  19. Usage and acceptability of HIV self-testing in men who have sex with men in Hong Kong.

    PubMed

    Wong, Horas Tze Hoo; Tam, Hoi Yan; Chan, Denise Pui Chung; Lee, Shui Shan

    2015-03-01

    Whilst studies on over-the-counter HIV tests continue to accumulate after FDA's approval of OraQuick Advance in 2012, few have focused on men who have sex with men (MSM) in Asian cities. An internet survey was conducted on 1,122 MSM in Hong Kong, revealing a low usage (6.1 %) and acceptability rate (43.8 %) on self-testing despite its availability in the market. Hierarchical logistic regression models showed that having received relevant information and users' attitudes on self-testing were the determinants of usage and acceptability. These factors had greater effects than sexual behaviors and social-networking on MSM's decision on self-testing. Majority of ever self-testers only repeated the self-test after a non-negative result, and overall only 26.6 % went for a formal test subsequent to the self-test. Concerns regarding the tests' accuracy were expressed by respondents. In conclusion, appropriate and accessible information and evidence-based guidance are needed to incorporate self-testing into HIV prevention strategies targeting MSM.

  20. 13. Photographic copy of site plan displaying Test Stand 'C' ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. Photographic copy of site plan displaying Test Stand 'C' (4217/E-18), Test Stand 'D' (4223/E-24), and Control and Recording Center (4221/E-22) with ancillary structures, and connecting roads and services. California Institute of Technology, Jet Propulsion Laboratory, Facilities Engineering and Construction Office 'Repairs to Test Stand 'C,' Edwards Test Station, Legend & Site Plan M-1,' drawing no. ESP/115, August 14, 1987. - Jet Propulsion Laboratory Edwards Facility, Test Stand C, Edwards Air Force Base, Boron, Kern County, CA

  1. Evaluating the impacts of reducing the number of hot mix asphalt plant testing acceptance criteria on mix variability.

    DOT National Transportation Integrated Search

    2012-11-01

    The acceptance testing of Hot Mix Asphalt (HMA) conducted at the HMA production facility is an : important portion of the overall acceptance process used by the Connecticut Department of : Transportation (ConnDOT) for paving projects. In 2004, ConnDO...

  2. Electric power system test and verification program

    NASA Technical Reports Server (NTRS)

    Rylicki, Daniel S.; Robinson, Frank, Jr.

    1994-01-01

    Space Station Freedom's (SSF's) electric power system (EPS) hardware and software verification is performed at all levels of integration, from components to assembly and system level tests. Careful planning is essential to ensure the EPS is tested properly on the ground prior to launch. The results of the test performed on breadboard model hardware and analyses completed to date have been evaluated and used to plan for design qualification and flight acceptance test phases. These results and plans indicate the verification program for SSF's 75-kW EPS would have been successful and completed in time to support the scheduled first element launch.

  3. Understanding Student Teachers' Behavioural Intention to Use Technology: Technology Acceptance Model (TAM) Validation and Testing

    ERIC Educational Resources Information Center

    Wong, Kung-Teck; Osman, Rosma bt; Goh, Pauline Swee Choo; Rahmat, Mohd Khairezan

    2013-01-01

    This study sets out to validate and test the Technology Acceptance Model (TAM) in the context of Malaysian student teachers' integration of their technology in teaching and learning. To establish factorial validity, data collected from 302 respondents were tested against the TAM using confirmatory factor analysis (CFA), and structural equation…

  4. Impact of pap test compliance and cervical cancer screening intervals on human papillomavirus vaccine acceptance.

    PubMed

    Ferris, Daron G; Waller, Jennifer; Dickinson, Ashley; McCracken, Courtney; Goebel, Angela

    2012-01-01

    The objective of this study was to determine the impact of Pap test compliance and cervical cancer screening intervals on human papillomavirus (HPV) vaccination acceptance. A convenience sample of 499 women 21 to 65 years old completed a 37-question survey in Augusta and Savannah, GA. The survey assessed their knowledge about HPV, cervical cancer, and the HPV vaccine. The questionnaire also determined their Pap test compliance and how longer Pap test intervals would influence their willingness to receive the HPV vaccine. Differences between categorical variables and knowledge scores were examined using χ test and unequal-variance t tests, respectively. Pap test-noncompliant women were more likely to get the HPV vaccine if they only needed a Pap test every 10 years compared with Pap test-compliant women (27.6% vs 14.6%, p = .02). A greater number (83.5%) of Pap test-noncompliant women preferred the HPV vaccine plus every 10-year Pap test option compared with Pap test-compliant women (31.3%, p < .0001). Most women (87%) responded that they would likely get the HPV vaccine if it would safely reduce the frequency of Pap testing. Women are receptive to getting the HPV vaccine in exchange for longer cervical cancer screening intervals. Moreover, Pap test-noncompliant women are more likely to get the HPV vaccine if Pap testing was needed less frequently. Increasing the Pap testing interval may be an excellent method to improving HPV vaccine acceptance in women at highest risk for cervical cancer.

  5. Halogen occultation experiment intergrated test plan

    NASA Technical Reports Server (NTRS)

    Mauldin, L. E., III; Butterfield, A. J.

    1986-01-01

    The test program plan is presented for the Halogen Occultation Experiment (HALOE) instrument, which is being developed in-house at the Langley Research Center for the Upper Atmosphere Research Satellite (UARS). This comprehensive test program was developed to demonstrate that the HALOE instrument meets its performance requirements and maintains integrity through UARS flight environments. Each component, subsystem, and system level test is described in sufficient detail to allow development of the necessary test setups and test procedures. Additionally, the management system for implementing this test program is given. The HALOE instrument is a gas correlation radiometer that measures vertical distribution of eight upper atmospheric constituents: O3, HC1, HF, NO, CH4, H2O, NO2, and CO2.

  6. Acceptance of New Technology: A Usability Test of a Computerized Adaptive Test for Fatigue in Rheumatoid Arthritis.

    PubMed

    Nikolaus, Stephanie; Bode, Christina; Taal, Erik; Vonkeman, Harald E; Glas, Cees Aw; van de Laar, Mart Afj

    2014-12-04

    Little is known about the acceptance and usability of computerized adaptive tests (CATs) among patients with rheumatoid arthritis (RA). The main difference between completing a CAT and a traditional questionnaire concerns item presentation. CATs only provide one item at a time on the screen, and skipping forward or backward to review and change already given answers is often not possible. The objective of this study was to examine how patients with RA experience a Web-based CAT for fatigue. In individual sessions, participants filled in the CAT while thinking aloud, and were subsequently interviewed about their experience with the new instrument. The technology acceptance model (TAM) was used to structure the results. The participants were 15 patients with RA. They perceived the CAT as clear, brief, and easy to use. They were positive about answering one question per screen, the changing response options, layout, progress bar, and item number. There were 40% (6/15) of the participants that also mentioned that they experienced the completion of the CAT as useful and pleasant, and liked the adaptive test mechanism. However, some participants noted that not all items were applicable to everybody, and that the wordings of questions within the severity dimension were often similar. Participants perceived the "CAT Fatigue RA" as easy to use, and also its usefulness was expressed. A 2.0 version has been improved according to the participants' comments, and is currently being used in a validation study before it will be implemented in daily clinical practice. Our results give a first indication that CAT methodology may outperform traditional questionnaires not merely on measurement precision, but also on usability and acceptance valuation.

  7. Acceptance testing and commissioning of Kodak Directview CR-850 digital radiography system.

    PubMed

    Bezak, E; Nelligan, R A

    2006-03-01

    This Technical Paper describes Acceptance Testing and Commissioning of the Kodak DirectView CR-850 digital radiography system installed at the Royal Adelaide Hospital. The first of its type installed in Australia, the system is a "dry" image processor, for which no chemicals are required to develop images. Rather, latent radiographic images are stored on photostimulable phosphor screens, which are scanned and displayed by a reader unit. The image can be digitally processed and enhanced before it is forwarded to a storage device, printer or workstation display, thereby alleviating the need to re-expose patients to achieve satisfactory quality images. The phosphor screens are automatically erased, ready for re-use. Results are reported of tests carried out using the optional "Total Quality Tool" quality assurance package installed with the system. This package includes analysis and reporting software which provides for simple testing and reporting of many important characteristics of the system, such as field uniformity, aspect ratio, line and pixel positions, image and system noise, exposure response, scan linearity, modulation transfer function (MTF) and image artefacts. Acceptance Tests were performed for kV and MV exposures. Resolution for MV exposures was at least 0.8 l/mm, and measured phantom dimensions were within 1.05% of expected magnification. Reproducibility between cassettes was within 1.6%. The mean pixel values on the central axis were close to linear for MV exposures from 3 to 10 MU and reached saturation level at around 20 MU for 6 MV and around 30 MV for 23 MV beams. Noise levels were below 0.2 %.

  8. Factors Affecting Acceptance & Use of ReWIND: Validating the Extended Unified Theory of Acceptance and Use of Technology

    ERIC Educational Resources Information Center

    Nair, Pradeep Kumar; Ali, Faizan; Leong, Lim Chee

    2015-01-01

    Purpose: This study aims to explain the factors affecting students' acceptance and usage of a lecture capture system (LCS)--ReWIND--in a Malaysian university based on the extended unified theory of acceptance and use of technology (UTAUT2) model. Technological advances have become an important feature of universities' plans to improve the…

  9. 30 CFR 282.23 - Testing Plan.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Resources BUREAU OF OCEAN ENERGY MANAGEMENT, REGULATION, AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR... lessee needs more information to develop a detailed Mining Plan than is obtainable under an approved... techniques or technology or mining equipment, or to determine environmental effects by a pilot test mining...

  10. 49 CFR Appendix B to Part 180 - Acceptable Internal Self-closing Stop Valve Leakage Tests for Cargo Tanks Transporting Liquefied...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Acceptable Internal Self-closing Stop Valve... Pt. 180, App. B Appendix B to Part 180—Acceptable Internal Self-closing Stop Valve Leakage Tests for Cargo Tanks Transporting Liquefied Compressed Gases For internal self-closing stop valve leakage testing...

  11. NASA's Plan for SDLS Testing

    NASA Technical Reports Server (NTRS)

    Bailey, Brandon

    2015-01-01

    The Space Data Link Security (SDLS) Protocol is a Consultative Committee for Space Data Systems (CCSDS) standard which extends the known Data Link protocols to secure data being sent over a space link by providing confidentiality and integrity services. This plan outlines the approach by National Aeronautics Space Administration (NASA) in performing testing of the SDLS protocol using a prototype based on an existing NASA missions simulator.

  12. The influence of various test plans on mission reliability. [for Shuttle Spacelab payloads

    NASA Technical Reports Server (NTRS)

    Stahle, C. V.; Gongloff, H. R.; Young, J. P.; Keegan, W. B.

    1977-01-01

    Methods have been developed for the evaluation of cost effective vibroacoustic test plans for Shuttle Spacelab payloads. The shock and vibration environments of components have been statistically represented, and statistical decision theory has been used to evaluate the cost effectiveness of five basic test plans with structural test options for two of the plans. Component, subassembly, and payload testing have been performed for each plan along with calculations of optimum test levels and expected costs. The tests have been ranked according to both minimizing expected project costs and vibroacoustic reliability. It was found that optimum costs may vary up to $6 million with the lowest plan eliminating component testing and maintaining flight vibration reliability via subassembly tests at high acoustic levels.

  13. 78 FR 65583 - Capital Planning and Stress Testing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-01

    ... comment. SUMMARY: NCUA proposes to conduct annual stress tests of federally insured credit unions (FICUs... Protection Act (the Dodd-Frank Act), requiring their supervised institutions to conduct annual stress tests... the credit union in its capital plans. Credit unions must also test the impact of interest rate shocks...

  14. Test plan. GCPS task 7, subtask 7.1: IHM development

    NASA Technical Reports Server (NTRS)

    Greenberg, H. S.

    1994-01-01

    The overall objective of Task 7 is to identify cost-effective life cycle integrated health management (IHM) approaches for a reusable launch vehicle's primary structure. Acceptable IHM approaches must: eliminate and accommodate faults through robust designs, identify optimum inspection/maintenance periods, automate ground and on-board test and check-out, and accommodate and detect structural faults by providing wide and localized area sensor and test coverage as required. These requirements are elements of our targeted primary structure low cost operations approach using airline-like maintenance by exception philosophies. This development plan will follow an evolutionary path paving the way to the ultimate development of flight-quality production, operations, and vehicle systems. This effort will be focused on maturing the recommended sensor technologies required for localized and wide area health monitoring to a technology readiness level (TRL) of 6 and to establish flight ready system design requirements. The following is a brief list of IHM program objectives: design out faults by analyzing material properties, structural geometry, and load and environment variables and identify failure modes and damage tolerance requirements; design in system robustness while meeting performance objectives (weight limitations) of the reusable launch vehicle primary structure; establish structural integrity margins to preclude the need for test and checkout and predict optimum inspection/maintenance periods through life prediction analysis; identify optimum fault protection system concept definitions combining system robustness and integrity margins established above with cost effective health monitoring technologies; and use coupons, panels, and integrated full scale primary structure test articles to identify, evaluate, and characterize the preferred NDE/NDI/IHM sensor technologies that will be a part of the fault protection system.

  15. Shuttle/Agena study. Volume 2, part 3: Preliminary test plans

    NASA Technical Reports Server (NTRS)

    1972-01-01

    Proposed testing for the Agena tug program is based upon best estimates of shuttle and Agena tug requirements and upon the Agena configuration currently envisioned to meet these requirements. The proposed tests are presented in development, qualification, system, and launch base test plans. These plans are based upon generalized requirements and assumed situations. The limitations of this study precluded all but minimal consideration of related shuttle orbiter and shuttle ground systems. The test plans include provisions for all testing from major component to systems level, identified as necessary to aid in confirmation of the modified Agena configuration for the space tug; considerations that crew safety requirements and new environmental conditions from shuttle interface effects do impose some new Agena testing requirements; considerations that many existing Agena flight-qualified components will be utilized and qualification testing will be minimal; testing not only for the Agena tug but also for new or modified items of handling or servicing equipment for supporting the Agena factory-to-launch sequence; and the assembly of required testing into a sequence-ordered series of events.

  16. Test plan for performance testing of the Eaton AC-3 electric vehicle

    NASA Astrophysics Data System (ADS)

    Crumley, R.; Heiselmann, H. W.

    1985-04-01

    An alternating current (ac) propulsion system for an electric vehicle was developed and tested. The test bed vehicle is a modified 1981 Mercury Lynx. The test plan was prepared specifically for the third modification to this test bed and identified as the Eaton AC-3. The scope of the testing done on the Eaton AC-3 includes coastdown and dynamometer tests but does not include environmental, on-road, or track testing. Coastdown testing is performed in accordance with SAE J-1263 (SAE Recommended Practice for Road Load Measurement and Dynamometer Simulation Using Coastdown Techniques).

  17. 1 Patient acceptability and feasibility of HIV testing in emergency departments in the UK - a systematic review and meta-analysis.

    PubMed

    Lungu, Nicola

    2017-12-01

    NICE 2016 HIV testing guidelines now include the recommendation to offer HIV testing in Emergency Departments, in areas of high prevalence, 1 to everyone who is undergoing blood tests. 23% of England's local authorities are areas of high HIV prevalence (>2/1000) and are therefore eligible. 2 So far very few Emergency Departments have implemented routine HIV testing. This systematic review assesses evidence for two implementation considerations: patient acceptability (how likely a patient will accept an HIV test when offered in an Emergency Department), and feasibility, which incorporates staff training and willingness, and department capacity, (how likely Emergency Department staff will offer an HIV test to an eligible patient), both measured by surrogate quantitative markers. Three medical databases were systematically searched for reports of non-targeted HIV testing in UK Emergency Departments. A total of 1584 unique papers were found, 9 full text articles were critically appraised, and 7 studies included in meta-analysis. There is a combined patient sample of 1 01 975. The primary outcome, patient acceptability of HIV testing in Emergency Departments (number of patients accepting an HIV test, as a proportion of those offered) is 54.1% (CI 40.1, 68.2). Feasibility (number of tests offered, as a proportion of eligible patients) is 36.2% (CI 9.8, 62.4). For an Emergency Department considering introducing routine HIV testing, this review suggests an opt-out publicity-lead strategy. Utilising oral fluid and blood tests would lead to the greatest proportion of eligible patients accepting an HIV test. For individual staff who are consenting patients for HIV testing, it may be encouraging to know that there is >50% chance the patient will accept an offer of testing.emermed;34/12/A860-a/T1F1T1Table 1Summary table of data extracted from final 7 studies, with calculated acceptability and feasibility if appropriate, and GRADE score. Studies listed in chronological

  18. Electronic health record acceptance by physicians: testing an integrated theoretical model.

    PubMed

    Gagnon, Marie-Pierre; Ghandour, El Kebir; Talla, Pascaline Kengne; Simonyan, David; Godin, Gaston; Labrecque, Michel; Ouimet, Mathieu; Rousseau, Michel

    2014-04-01

    Several countries are in the process of implementing an Electronic Health Record (EHR), but limited physicians' acceptance of this technology presents a serious threat to its successful implementation. The aim of this study was to identify the main determinants of physician acceptance of EHR in a sample of general practitioners and specialists of the Province of Quebec (Canada). We sent an electronic questionnaire to physician members of the Quebec Medical Association. We tested four theoretical models (Technology acceptance model (TAM), Extended TAM, Psychosocial Model, and Integrated Model) using path analysis and multiple linear regression analysis in order to identify the main determinants of physicians' intention to use the EHR. We evaluated the modifying effect of sociodemographic characteristics using multi-group analysis of structural weights invariance. A total of 157 questionnaires were returned. The four models performed well and explained between 44% and 55% of the variance in physicians' intention to use the EHR. The Integrated model performed the best and showed that perceived ease of use, professional norm, social norm, and demonstrability of the results are the strongest predictors of physicians' intention to use the EHR. Age, gender, previous experience and specialty modified the association between those determinants and intention. The proposed integrated theoretical model is useful in identifying which factors could motivate physicians from different backgrounds to use the EHR. Physicians who perceive the EHR to be easy to use, coherent with their professional norms, supported by their peers and patients, and able to demonstrate tangible results are more likely to accept this technology. Age, gender, specialty and experience should also be taken into account when developing EHR implementation strategies targeting physicians. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Definition study of a Variable Cycle Experimental Engine (VCEE) and associated test program and test plan

    NASA Technical Reports Server (NTRS)

    Allan, R. D.

    1978-01-01

    The Definition Study of a Variable Cycle Experimental Engine (VCEE) and Associated Test Program and Test Plan, was initiated to identify the most cost effective program for a follow-on to the AST Test Bed Program. The VCEE Study defined various subscale VCE's based on different available core engine components, and a full scale VCEE utilizing current technology. The cycles were selected, preliminary design accomplished and program plans and engineering costs developed for several program options. In addition to the VCEE program plans and options, a limited effort was applied to identifying programs that could logically be accomplished on the AST Test Bed Program VCE to extend the usefulness of this test hardware. Component programs were provided that could be accomplished prior to the start of a VCEE program.

  20. High Burnup Dry Storage Cask Research and Development Project, Final Test Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2014-02-27

    EPRI is leading a project team to develop and implement the first five years of a Test Plan to collect data from a SNF dry storage system containing high burnup fuel.12 The Test Plan defined in this document outlines the data to be collected, and the storage system design, procedures, and licensing necessary to implement the Test Plan.13 The main goals of the proposed test are to provide confirmatory data14 for models, future SNF dry storage cask design, and to support license renewals and new licenses for ISFSIs. To provide data that is most relevant to high burnup fuel inmore » dry storage, the design of the test storage system must mimic real conditions that high burnup SNF experiences during all stages of dry storage: loading, cask drying, inert gas backfilling, and transfer to the ISFSI for multi-year storage.15 Along with other optional modeling, SETs, and SSTs, the data collected in this Test Plan can be used to evaluate the integrity of dry storage systems and the high burnup fuel contained therein over many decades. It should be noted that the Test Plan described in this document discusses essential activities that go beyond the first five years of Test Plan implementation.16 The first five years of the Test Plan include activities up through loading the cask, initiating the data collection, and beginning the long-term storage period at the ISFSI. The Test Plan encompasses the overall project that includes activities that may not be completed until 15 or more years from now, including continued data collection, shipment of the Research Project Cask to a Fuel Examination Facility, opening the cask at the Fuel Examination Facility, and examining the high burnup fuel after the initial storage period.« less

  1. Development and Test Plans for the MSR EEV

    NASA Technical Reports Server (NTRS)

    Dillman, Robert; Laub, Bernard; Kellas, Sotiris; Schoenenberger, Mark

    2005-01-01

    The goal of the proposed Mars Sample Return mission is to bring samples from the surface of Mars back to Earth for thorough examination and analysis. The Earth Entry Vehicle is the passive entry body designed to protect the sample container from entry heating and deceleration loads during descent through the Earth s atmosphere to a recoverable location on the surface. This paper summarizes the entry vehicle design and outlines the subsystem development and testing currently planned in preparation for an entry vehicle flight test in 2010 and mission launch in 2013. Planned efforts are discussed for the areas of the thermal protection system, vehicle trajectory, aerodynamics and aerothermodynamics, impact energy absorption, structure and mechanisms, and the entry vehicle flight test.

  2. Examining the Intention to Use Technology among Pre-Service Teachers: An Integration of the Technology Acceptance Model and Theory of Planned Behavior

    ERIC Educational Resources Information Center

    Teo, Timothy

    2012-01-01

    This study examined pre-service teachers' self-reported intention to use technology. One hundred fifty-seven participants completed a survey questionnaire measuring their responses to six constructs from a research model that integrated the Technology Acceptance Model (TAM) and Theory of Planned Behavior (TPB). Structural equation modeling was…

  3. Patients’ Acceptance of Smartphone Health Technology for Chronic Disease Management: A Theoretical Model and Empirical Test

    PubMed Central

    Dou, Kaili; Yu, Ping; Liu, Fang; Guan, YingPing; Li, Zhenye; Ji, Yumeng; Du, Ningkai; Lu, Xudong; Duan, Huilong

    2017-01-01

    Background Chronic disease patients often face multiple challenges from difficult comorbidities. Smartphone health technology can be used to help them manage their conditions only if they accept and use the technology. Objective The aim of this study was to develop and test a theoretical model to predict and explain the factors influencing patients’ acceptance of smartphone health technology for chronic disease management. Methods Multiple theories and factors that may influence patients’ acceptance of smartphone health technology have been reviewed. A hybrid theoretical model was built based on the technology acceptance model, dual-factor model, health belief model, and the factors identified from interviews that might influence patients’ acceptance of smartphone health technology for chronic disease management. Data were collected from patient questionnaire surveys and computer log records about 157 hypertensive patients’ actual use of a smartphone health app. The partial least square method was used to test the theoretical model. Results The model accounted for .412 of the variance in patients’ intention to adopt the smartphone health technology. Intention to use accounted for .111 of the variance in actual use and had a significant weak relationship with the latter. Perceived ease of use was affected by patients’ smartphone usage experience, relationship with doctor, and self-efficacy. Although without a significant effect on intention to use, perceived ease of use had a significant positive influence on perceived usefulness. Relationship with doctor and perceived health threat had significant positive effects on perceived usefulness, countering the negative influence of resistance to change. Perceived usefulness, perceived health threat, and resistance to change significantly predicted patients’ intentions to use the technology. Age and gender had no significant influence on patients’ acceptance of smartphone technology. The study also

  4. Effects of an Educational Experience Incorporating an Inventory of Factors Potentially Influencing Student Acceptance of Biological Evolution

    NASA Astrophysics Data System (ADS)

    Wiles, Jason R.; Alters, Brian

    2011-12-01

    This investigation provides an extensive review of scientific, religious, and otherwise non-scientific factors that may influence student acceptance of biological evolution. We also measure the extent to which students' levels of acceptance changed following an educational experience designed to address an inclusive inventory of factors identified as potentially affecting student acceptance of evolution (n = 81, pre-test/post-test) n = 37, one-year longitudinal). Acceptance of evolution was measured using the Measure of Acceptance of the Theory of Evolution (MATE) instrument among participants enrolled in a secondary-level academic programme during the summer prior to their final year of high school and as they transitioned to the post-secondary level. Student acceptance of evolution was measured to be significantly higher than initial levels both immediately following and over one year after the educational experience. Results reported herein carry implications for future quantitative and qualitative research as well as for cross-disciplinary instruction plans related to evolutionary science and non-scientific factors which may influence student understanding of evolution.

  5. 46 CFR 162.060-24 - Test Plan requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... (including the test facility's standard operating procedures for achieving such conditions). (9) Sampling.... Test Plans must include an examination of all the manufacturer's stated requirements and procedures for... potential environmental, health, and safety issues; unusual operating requirements; and any issues related...

  6. 46 CFR 162.060-24 - Test Plan requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... (including the test facility's standard operating procedures for achieving such conditions). (9) Sampling.... Test Plans must include an examination of all the manufacturer's stated requirements and procedures for... potential environmental, health, and safety issues; unusual operating requirements; and any issues related...

  7. 46 CFR 162.060-24 - Test Plan requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... (including the test facility's standard operating procedures for achieving such conditions). (9) Sampling.... Test Plans must include an examination of all the manufacturer's stated requirements and procedures for... potential environmental, health, and safety issues; unusual operating requirements; and any issues related...

  8. Parametric evaluation of the cost effectiveness of Shuttle payload vibroacoustic test plans

    NASA Technical Reports Server (NTRS)

    Stahle, C. V.; Gongloff, H. R.; Keegan, W. B.; Young, J. P.

    1978-01-01

    Consideration is given to alternate vibroacoustic test plans for sortie and free flyer Shuttle payloads. Statistical decision models for nine test plans provide a viable method of evaluating the cost effectiveness of alternate vibroacoustic test plans and the associated test levels. The methodology is a major step toward the development of a useful tool for the quantitative tailoring of vibroacoustic test programs to sortie and free flyer payloads. A broader application of the methodology is now possible by the use of the OCTAVE computer code.

  9. Computer Administered Safety Planning for Individuals at Risk for Suicide: Development and Usability Testing.

    PubMed

    Boudreaux, Edwin D; Brown, Gregory K; Stanley, Barbara; Sadasivam, Rajani S; Camargo, Carlos A; Miller, Ivan W

    2017-05-15

    Safety planning is a brief intervention that has become an accepted practice in many clinical settings to help prevent suicide. Even though it is quick compared to other approaches, it frequently requires 20 min or more to complete, which can impede adoption. A self-administered, Web-based safety planning application could potentially reduce clinician time, help promote standardization and quality, and provide enhanced ability to share the created plan. The aim of this study was to design, build, and test the usability of a Web-based, self-administered safety planning application. We employed a user-centered software design strategy led by a multidisciplinary team. The application was tested for usability with a target sample of suicidal patients. Detailed observations, structured usability ratings, and Think Aloud procedures were used. Suicidal ideation intensity and perceived ability to cope were assessed pre-post engagement with the Web application. A total of 30 participants were enrolled. Usability ratings were generally strong, and all patients successfully built a safety plan. However, the completeness of the safety plan varied. The mean number of steps completed was 5.5 (SD 0.9) out of 6, with 90% (27/30) of participants completing at least 5 steps and 67% (20/30) completing all 6 steps. Some safety planning steps were viewed as inapplicable to some individuals. Some confusion in instructions led to modifications to improve understandability of each step. Ratings of suicide intensity after completion of the application were significantly lower than preratings, pre: mean 5.11 (SD 2.9) versus post: mean 4.46 (SD 3.0), t 27 =2.49, P=.02. Ratings of ability to cope with suicidal thoughts after completion of the application were higher than preratings, with the difference approaching statistical significance, pre: mean 5.93 (SD 2.9), post: mean 6.64 (SD 2.4), t 27 =-2.03, P=.05. We have taken the first step toward identifying the components needed to maximize

  10. Single Event Effects (SEE) Testing: Practical Approach to Test Plans

    NASA Technical Reports Server (NTRS)

    LaBel, Kenneth A.; Pellish, Jonathan Allen; Berg, Melanie D.

    2014-01-01

    While standards and guidelines for performing SEE testing have existed for several decades, guidance for developing SEE test plans has not been as easy to find. In this presentation, the variety of areas that need to be considered ranging from resource issues (funds, personnel, schedule) to extremely technical challenges (particle interaction and circuit application), shall be discussed. Note: we consider the approach outlined here as a "living" document: Mission-specific constraints and new technology related issues always need to be taken into account.

  11. Detailed Test Plan Redundant Sensor Strapdown IMU Evaluation Program

    NASA Technical Reports Server (NTRS)

    Hartwell, T.; Miyatake, Y.; Wedekind, D. E.

    1971-01-01

    The test plan for a redundant sensor strapdown inertial measuring unit evaluation program is presented. The subjects discussed are: (1) test philosophy and limitations, (2) test sequence, (3) equipment specifications, (4) general operating procedures, (5) calibration procedures, (6) alignment test phase, and (7) navigation test phase. The data and analysis requirements are analyzed.

  12. Criteria required for an acceptable point-of-care test for UTI detection: Obtaining consensus using the Delphi technique.

    PubMed

    Weir, Nichola-Jane M; Pattison, Sally H; Kearney, Paddy; Stafford, Bob; Gormley, Gerard J; Crockard, Martin A; Gilpin, Deirdre F; Tunney, Michael M; Hughes, Carmel M

    2018-01-01

    Urinary Tract Infections (UTIs) are common bacterial infections, second only to respiratory tract infections and particularly prevalent within primary care. Conventional detection of UTIs is culture, however, return of results can take between 24 and 72 hours. The introduction of a point of care (POC) test would allow for more timely identification of UTIs, facilitating improved, targeted treatment. This study aimed to obtain consensus on the criteria required for a POC UTI test, to meet patient need within primary care. Criteria for consideration were compiled by the research team. These criteria were validated through a two-round Delphi process, utilising an expert panel of healthcare professionals from across Europe and United States of America. Using web-based questionnaires, panellists recorded their level of agreement with each criterion based on a 5-point Likert Scale, with space for comments. Using median response, interquartile range and comments provided, criteria were accepted/rejected/revised depending on pre-agreed cut-off scores. The first round questionnaire presented thirty-three criteria to the panel, of which 22 were accepted. Consensus was not achieved for the remaining 11 criteria. Following response review, one criterion was removed, while after revision, the remaining 10 criteria entered the second round. Of these, four were subsequently accepted, resulting in 26 criteria considered appropriate for a POC test to detect urinary infections. This study generated an approved set of criteria for a POC test to detect urinary infections. Criteria acceptance and comments provided by the healthcare professionals also supports the development of a multiplex point of care UTI test.

  13. Test Plan Procedure for Experiment T-003

    DOT National Transportation Integrated Search

    1971-05-19

    This document defines the type, sequence, and procedural details required to perform each test on the T-003 experiment aerosol analyzer, its subsystems and components. This plan utilizes the flexibility allowed for instruments in criticality category...

  14. Work plan for cone penetrometer comparison testing.

    DOT National Transportation Integrated Search

    2011-01-01

    The work plan and experimental design are developed around aiding engineers and geologists within the : Wisconsin Department of Transportation to understand the mechanisms controlling cone penetration test : results so that they can decide when the t...

  15. Early experiences on the feasibility, acceptability, and use of malaria rapid diagnostic tests at peripheral health centres in Uganda-insights into some barriers and facilitators.

    PubMed

    Asiimwe, Caroline; Kyabayinze, Daniel J; Kyalisiima, Zephaniah; Nabakooza, Jane; Bajabaite, Moses; Counihan, Helen; Tibenderana, James K

    2012-01-23

    While feasibility of new health technologies in well-resourced healthcare settings is extensively documented, it is largely unknown in low-resourced settings. Uganda's decision to deploy and scale up malaria rapid diagnostic tests (mRDTs) in public health facilities and at the community level provides a useful entry point for documenting field experience, acceptance, and predictive variables for technology acceptance and use. These findings are important in informing implementation of new health technologies, plans, and budgets in low-resourced national disease control programmes. A cross-sectional qualitative descriptive study at 21 health centres in Uganda was undertaken in 2007 to elucidate the barriers and facilitators in the introduction of mRDTs as a new diagnostic technology at lower-level health facilities. Pre-tested interview questionnaires were administered through pre-structured patient exit interviews and semi-structured health worker interviews to gain an understanding of the response to this implementation. A conceptual framework on technology acceptance and use was adapted for this study and used to prepare the questionnaires. Thematic analysis was used to generate themes from the data. A total of 52 of 57 health workers (92%) reported a belief that a positive mRDT result was true, although only 41 of 57 (64%) believed that treatment with anti-malarials was justified for every positive mRDT case. Of the same health workers, only 49% believed that a negative mRDT result was truly negative. Factors linked to these findings were related to mRDT acceptance and use, including the design and characteristics of the device, availability and quality of mRDT ancillary supplies, health worker capacity to investigate febrile cases testing negative with the device and provide appropriate treatment, availability of effective malaria treatments, reliability of the health commodity supply chain, existing national policy recommendations, individual health worker

  16. The Feasibility and Acceptability of "Arise": An Online Substance Abuse Relapse Prevention Program.

    PubMed

    Sanchez, Rebecca Polley; Bartel, Chelsea M

    2015-04-01

    The purpose of this study was to test the feasibility and acceptability of a novel online adolescent substance abuse relapse prevention tool, "Arise" (3C Institute, Cary, NC). The program uses an innovative platform including interactive instructional segments and skill-building games to help adolescents learn and practice coping skills training strategies. We conducted a pilot test with nine adolescents in substance abuse treatment (44 percent female) and a feasibility test with treatment providers (n=8; 50 percent female). Adolescents interacted with the program via a secure Web site for approximately 30 minutes for each of two instructional units. Treatment providers reviewed the same material at their own pace. All participants completed a questionnaire with items assessing usability, acceptability, understanding, and subjective experience of the program. Regarding feasibility, recruitment of this population within the study constraints proved challenging, but participant retention in the trial was high (no attrition). Adolescents and treatment providers completed the program with no reported problems, and overall we were able to collect data as planned. Regarding acceptability, the program received strong ratings from both adolescents and providers, who found the prototype informative, engaging, and appealing. Both groups strongly recommended continuing development. We were able to deliver the intervention as intended, and acceptability ratings were high, demonstrating the feasibility and acceptability of online delivery of engaging interactive interventions. This study contributes to our understanding of how interactive technologies, including games, can be used to modify behavior in substance abuse treatment and other health areas.

  17. Adherence to dietary recommendations in diabetes mellitus: disease acceptance as a potential mediator.

    PubMed

    Jaworski, Mariusz; Panczyk, Mariusz; Cedro, Małgorzata; Kucharska, Alicja

    2018-01-01

    Adherence by diabetic patients to dietary recommendations is important for effective therapy. Considering patients' expectations in case of diet is significant in this regard. The aim of this paper was to analyze the relationship between selected independent variables (eg, regular blood glucose testing) and patients' adherence to dietary recommendations, bearing in mind that the degree of disease acceptance might play a mediation role. A cross-sectional study was conducted in 91 patients treated for type 2 diabetes mellitus in a public medical facility. Paper-and-pencil interviewing was administered ahead of the planned visit with a diabetes specialist. Two measures were applied in the study: the Acceptance and Action Diabetes Questionnaire and the Patient Diet Adherence in Diabetes Scale. Additionally, data related to sociodemographic characteristics, lifestyle-related factors, and the course of the disease (management, incidence of complications, and dietician's supervision) were also collected. The regression method was used in the analysis, and Cohen's methodology was used to estimate partial mediation. Significance of the mediation effect was assessed by the Goodman test. P -values of <0.05 were considered statistically significant. Patients' non-adherence to dietary recommendations was related to a low level of disease acceptance (standardized regression coefficient =-0.266; P =0.010). Moreover, failure to perform regular blood glucose testing was associated with a lack of disease acceptance (standardized regression coefficient =-0.455; P =0.000). However, the lack of regular blood glucose testing and low level of acceptance had only partially negative impacts on adherence to dietary recommendations (Goodman mediation test, Z =1.939; P =0.054). This dependence was not seen in patients treated with diet and concomitant oral medicines and/or insulin therapy. Effective dietary education should include activities promoting a more positive attitude toward the

  18. "Unspoken Agreements": Perceived Acceptability of Couples HIV Testing and Counseling (CHTC) Among Cisgender Men with Transgender Women Partners.

    PubMed

    Reisner, Sari L; Menino, David; Leung, Kingsley; Gamarel, Kristi E

    2018-06-23

    Transgender women (TW) are one of the highest risk groups for HIV infection globally; however, the HIV testing needs of their cisgender (non-transgender) male partners remain largely unknown. This study sought to examine the perceived acceptability of couples HIV testing and counseling (CHTC) for TW-male dyads from the perspective of cisgender men who partner with TW. Between September 2016 and June 2017, 19 cisgender men (mean age = 40.1, SD = 12.8) who currently have, or have ever had a TW partner completed an in-depth semi-structured phone interview and brief survey to gather data on acceptability of CHTC, as well as perceived barriers and facilitators to CHTC for TW-male couples. Qualitative data were thematically analyzed and integrated with survey data. Acceptability of CHTC was high in the sample (89.5%) but was complex and largely contingent on: (1) monogamy and commitment as critical precursors to CHTC acceptability; (2) risk perception and level of comfort with CHTC; (3) understandings of sexual agreements; and (4) personal relationships versus other TW-male relationships. Findings have implications for culturally-adapting and implementing CHTC in real-world settings for TW-male couples, as well as for meeting the individual HIV testing needs of cisgender men who partner with TW.

  19. 14 CFR 437.25 - Flight test plan.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false Flight test plan. 437.25 Section 437.25 Aeronautics and Space COMMERCIAL SPACE TRANSPORTATION, FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... reusable suborbital rocket. Operational Safety Documentation ...

  20. 14 CFR 437.25 - Flight test plan.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Flight test plan. 437.25 Section 437.25 Aeronautics and Space COMMERCIAL SPACE TRANSPORTATION, FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... reusable suborbital rocket. Operational Safety Documentation ...

  1. Bridging the Gap between Social Acceptance and Ethical Acceptability.

    PubMed

    Taebi, Behnam

    2017-10-01

    New technology brings great benefits, but it can also create new and significant risks. When evaluating those risks in policymaking, there is a tendency to focus on social acceptance. By solely focusing on social acceptance, we could, however, overlook important ethical aspects of technological risk, particularly when we evaluate technologies with transnational and intergenerational risks. I argue that good governance of risky technology requires analyzing both social acceptance and ethical acceptability. Conceptually, these two notions are mostly complementary. Social acceptance studies are not capable of sufficiently capturing all the morally relevant features of risky technologies; ethical analyses do not typically include stakeholders' opinions, and they therefore lack the relevant empirical input for a thorough ethical evaluation. Only when carried out in conjunction are these two types of analysis relevant to national and international governance of risky technology. I discuss the Rawlsian wide reflective equilibrium as a method for marrying social acceptance and ethical acceptability. Although the rationale of my argument is broadly applicable, I will examine the case of multinational nuclear waste repositories in particular. This example will show how ethical issues may be overlooked if we focus only on social acceptance, and will provide a test case for demonstrating how the wide reflective equilibrium can help to bridge the proverbial acceptance-acceptability gap. © 2016 The Authors Risk Analysis published by Wiley Periodicals, Inc. on behalf of Society for Risk Analysis.

  2. 33 CFR 157.106 - Letter of acceptance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Crude Oil Washing (COW) System on Tank Vessels General § 157.106 Letter of acceptance. The Coast Guard...) The plans submitted show that the COW system meets this subpart; or (b) The plans submitted and the scale model under § 157.104 show that the COW system meets this subpart. ...

  3. Patients' Acceptance of Smartphone Health Technology for Chronic Disease Management: A Theoretical Model and Empirical Test.

    PubMed

    Dou, Kaili; Yu, Ping; Deng, Ning; Liu, Fang; Guan, YingPing; Li, Zhenye; Ji, Yumeng; Du, Ningkai; Lu, Xudong; Duan, Huilong

    2017-12-06

    Chronic disease patients often face multiple challenges from difficult comorbidities. Smartphone health technology can be used to help them manage their conditions only if they accept and use the technology. The aim of this study was to develop and test a theoretical model to predict and explain the factors influencing patients' acceptance of smartphone health technology for chronic disease management. Multiple theories and factors that may influence patients' acceptance of smartphone health technology have been reviewed. A hybrid theoretical model was built based on the technology acceptance model, dual-factor model, health belief model, and the factors identified from interviews that might influence patients' acceptance of smartphone health technology for chronic disease management. Data were collected from patient questionnaire surveys and computer log records about 157 hypertensive patients' actual use of a smartphone health app. The partial least square method was used to test the theoretical model. The model accounted for .412 of the variance in patients' intention to adopt the smartphone health technology. Intention to use accounted for .111 of the variance in actual use and had a significant weak relationship with the latter. Perceived ease of use was affected by patients' smartphone usage experience, relationship with doctor, and self-efficacy. Although without a significant effect on intention to use, perceived ease of use had a significant positive influence on perceived usefulness. Relationship with doctor and perceived health threat had significant positive effects on perceived usefulness, countering the negative influence of resistance to change. Perceived usefulness, perceived health threat, and resistance to change significantly predicted patients' intentions to use the technology. Age and gender had no significant influence on patients' acceptance of smartphone technology. The study also confirmed the positive relationship between intention to use

  4. Disintegration of sublingual tablets: proposal for a validated test method and acceptance criterion.

    PubMed

    Weda, M; van Riet-Nales, D A; van Aalst, P; de Kaste, D; Lekkerkerker, J F F

    2006-12-01

    In the Netherlands the market share of isosorbide dinitrate 5 mg sublingual tablets is dominated by 2 products (A and B). In the last few years complaints have been received from health care professionals on product B. During patient use the disintegration of the tablet was reported to be slow and/or incomplete, and ineffectiveness was experienced. In the European Pharmacopoeia (Ph. Eur.) no requirement is present for the disintegration time of sublingual tablets. The purpose of this study was to compare the in vitro disintegration time of products A and B, and to establish a suitable test method and acceptance criterion. A and B were tested with the Ph. Eur. method described in the monograph on disintegration of tablets and capsules as well as with 3 modified tests using the same Ph. Eur. apparatus, but without movement of the basket-rack assembly. In modified test 1 and modified test 2 water was used as medium (900 ml and 50 ml respectively), whereas in modified test 3 artificial saliva was used (50 ml). In addition, disintegration was tested in Nessler tubes with 0.5 and 2 ml of water. Finally, the Ph. Eur. method was also applied to other sublingual tablets with other drug substances on the Dutch market. With modified test 3 no disintegration could be achieved within 20 min. With the Ph. Eur. method and modified tests 1 and 2 product A and B differed significantly (p < 0. 001), with product B having longer disintegration times. These 3 methods were capable of discriminating between products and between batches. The time measured with the Ph. Eur. method was significantly lower compared to modified tests 1 and 2 (p < 0.001) and correlated well with the Nessler tube results. It is concluded that the in vivo complaints on product B could be related to the in vitro data. Furthermore, it is proposed that for immediate release of sublingual tablets the disintegration time should be tested. The Ph. Eur. method is considered suitable for this test. In view of the

  5. Test, Control and Monitor System maintenance plan

    NASA Technical Reports Server (NTRS)

    Buehler, David P.; Lougheed, M. J.

    1993-01-01

    The maintenance requirements for Test, Control, and Monitor System (TCMS) and the method for satisfying these requirements prior to First Need Date (FND) of the last TCMS set are described. The method for satisfying maintenance requirements following FND of the last TCMS set will be addressed by a revision to this plan. This maintenance plan serves as the basic planning document for maintenance of this equipment by the NASA Payloads Directorate (CM) and the Payload Ground Operations Contractor (PGOC) at KSC. The terms TCMS Operations and Maintenance (O&M), Payloads Logistics, TCMS Sustaining Engineering, Payload Communications, and Integrated Network Services refer to the appropriate NASA and PGOC organization. For the duration of their contract, the Core Electronic Contractor (CEC) will provide a Set Support Team (SST). One of the primary purposes of this team is to help NASA and PGOC operate and maintain TCMS. It is assumed that SST is an integral part of TCMS O&M. The purpose of this plan is to describe the maintenance concept for TCMS hardware and system software in order to facilitate activation, transition planning, and continuing operation. When software maintenance is mentioned in this plan, it refers to maintenance of TCMS system software.

  6. Acceptance tests of various upper torso restraints.

    DOT National Transportation Integrated Search

    1971-03-01

    The study demonstrates that people can be motivated to utilize and, in fact, eagerly accept the use of upper torso restraint equipment for the prevention of head and chest injuries induced by flailing during crash decelerations, provided that specifi...

  7. Evaluation program for secondary spacecraft cells: Acceptance test of McDonnell-Douglas, Astropower division, 40.0 ampere hour silver-zinc cells

    NASA Technical Reports Server (NTRS)

    Harkness, J. D.

    1971-01-01

    The development of an inorganic separator material for use in construction of 40 ampere-hour silver zinc cells is discussed. Acceptance tests were conducted to determine real quality, physical defects and ampere-hour capacity. All acceptance tests were performed at an ambient temperature of 23 to 27 C at existing relative humidity and atmospheric pressure. Of the 63 cells tested, only one failed to meet the equipment specifications.

  8. Launch vehicle test and checkout plan. - Volume 2: Saturn 1B launch vehicle Skylab R (rescue) and AS-208 flow plan and listings

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The launch operations test and checkout plan is a planning document that establishes all launch site checkout activity, including the individual tests and sequence of testing required to fulfill the development center and KSC test and checkout requirements. This volume contains the launch vehicle test and checkout plan encompassing S-1B, S-4B, IU stage, and ground support equipment tests. The plan is based upon AS-208 flow utilizing a manned spacecraft, LUT 1, and launch pad 39B facilities.

  9. Criteria required for an acceptable point-of-care test for UTI detection: Obtaining consensus using the Delphi technique

    PubMed Central

    Kearney, Paddy; Stafford, Bob; Gormley, Gerard J.; Crockard, Martin A.; Gilpin, Deirdre F.

    2018-01-01

    Background Urinary Tract Infections (UTIs) are common bacterial infections, second only to respiratory tract infections and particularly prevalent within primary care. Conventional detection of UTIs is culture, however, return of results can take between 24 and 72 hours. The introduction of a point of care (POC) test would allow for more timely identification of UTIs, facilitating improved, targeted treatment. This study aimed to obtain consensus on the criteria required for a POC UTI test, to meet patient need within primary care. Methods Criteria for consideration were compiled by the research team. These criteria were validated through a two-round Delphi process, utilising an expert panel of healthcare professionals from across Europe and United States of America. Using web-based questionnaires, panellists recorded their level of agreement with each criterion based on a 5-point Likert Scale, with space for comments. Using median response, interquartile range and comments provided, criteria were accepted/rejected/revised depending on pre-agreed cut-off scores. Results The first round questionnaire presented thirty-three criteria to the panel, of which 22 were accepted. Consensus was not achieved for the remaining 11 criteria. Following response review, one criterion was removed, while after revision, the remaining 10 criteria entered the second round. Of these, four were subsequently accepted, resulting in 26 criteria considered appropriate for a POC test to detect urinary infections. Conclusion This study generated an approved set of criteria for a POC test to detect urinary infections. Criteria acceptance and comments provided by the healthcare professionals also supports the development of a multiplex point of care UTI test. PMID:29879161

  10. International Fusion Materials Irradiation Facility injector acceptance tests at CEA/Saclay: 140 mA/100 keV deuteron beam characterization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gobin, R., E-mail: rjgobin@cea.fr; Bogard, D.; Chauvin, N.

    In the framework of the ITER broader approach, the International Fusion Materials Irradiation Facility (IFMIF) deuteron accelerator (2 × 125 mA at 40 MeV) is an irradiation tool dedicated to high neutron flux production for future nuclear plant material studies. During the validation phase, the Linear IFMIF Prototype Accelerator (LIPAc) machine will be tested on the Rokkasho site in Japan. This demonstrator aims to produce 125 mA/9 MeV deuteron beam. Involved in the LIPAc project for several years, specialists from CEA/Saclay designed the injector based on a SILHI type ECR source operating at 2.45 GHz and a 2 solenoid lowmore » energy beam line to produce such high intensity beam. The whole injector, equipped with its dedicated diagnostics, has been then installed and tested on the Saclay site. Before shipment from Europe to Japan, acceptance tests have been performed in November 2012 with 100 keV deuteron beam and intensity as high as 140 mA in continuous and pulsed mode. In this paper, the emittance measurements done for different duty cycles and different beam intensities will be presented as well as beam species fraction analysis. Then the reinstallation in Japan and commissioning plan on site will be reported.« less

  11. General Vehicle Test Plan (GVTP) for Urban Rail Transit Cars

    DOT National Transportation Integrated Search

    1977-09-01

    The General Vehicle Test Plan provides a system for general vehicle testing and for documenting and utilizing data and information in the testing of urban rail transit cars. Test procedures are defined for nine categories: (1) Performance; (2) Power ...

  12. ENRAF Series 854 Advanced Technology Gauge (ATG) with SPU II card for Leak Detector Use Acceptance Test Procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SMITH, S.G.

    1999-10-21

    The following Acceptance Test Procedure was written to test the ENRAF series 854 ATG with SPU II card prior to installation in the Tank Farms. The procedure sets various parameters and verifies the gauge and alarms functionality.

  13. Acceptability of male condom: An Indian scenario

    PubMed Central

    Donta, Balaiah; Begum, Shahina; Naik, D.D.

    2014-01-01

    The National Family Planning Programme of India had introduced condom as one of the family planning methods in the late1960s. Condom was promoted as a family planning method through social marketing since its inception. With the increasing prevalence and incidence of sexually transmitted infections (STIs) including HIV/AIDS, condom was also promoted as a dual method for protection against both unintended pregnancies as well as sexually transmitted infections. Despite efforts at various levels, the overall use of condom among couples in India is low. Here we present literature review of studies to understand the condom acceptability among couples in India. Specifically, the paper assesses research and programmes that have been carried out to increase the use of condom among couples; determinants of condom use; reason for not using condom; and perception versus experience of condom failure. The reported problems related to condom use included non acceptance by partner, perceived ineffectiveness, less comfort, lack of sexual satisfaction, husband's alcohol use, depression, and anxiety, and not available at that instant. The role of media in the promotion of condom use was indicated as an important way to increase awareness and use. Multiple strategies would help in acceptance of male condom. PMID:25673537

  14. TRACON Aircraft Arrival Planning and Optimization Through Spatial Constraint Satisfaction

    NASA Technical Reports Server (NTRS)

    Bergh, Christopher P.; Krzeczowski, Kenneth J.; Davis, Thomas J.; Denery, Dallas G. (Technical Monitor)

    1995-01-01

    A new aircraft arrival planning and optimization algorithm has been incorporated into the Final Approach Spacing Tool (FAST) in the Center-TRACON Automation System (CTAS) developed at NASA-Ames Research Center. FAST simulations have been conducted over three years involving full-proficiency, level five air traffic controllers from around the United States. From these simulations an algorithm, called Spatial Constraint Satisfaction, has been designed, coded, undergone testing, and soon will begin field evaluation at the Dallas-Fort Worth and Denver International airport facilities. The purpose of this new design is an attempt to show that the generation of efficient and conflict free aircraft arrival plans at the runway does not guarantee an operationally acceptable arrival plan upstream from the runway -information encompassing the entire arrival airspace must be used in order to create an acceptable aircraft arrival plan. This new design includes functions available previously but additionally includes necessary representations of controller preferences and workload, operationally required amounts of extra separation, and integrates aircraft conflict resolution. As a result, the Spatial Constraint Satisfaction algorithm produces an optimized aircraft arrival plan that is more acceptable in terms of arrival procedures and air traffic controller workload. This paper discusses the current Air Traffic Control arrival planning procedures, previous work in this field, the design of the Spatial Constraint Satisfaction algorithm, and the results of recent evaluations of the algorithm.

  15. Pilot-scale treatability test plan for the 200-BP-5 operable unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This document presents the treatability test plan for pilot-scale pump and treat testing at the 200-BP-5 Operable Unit. This treatability test plan has been prepared in response to an agreement between the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency (EPA), and the State of Washington Department of Ecology (Ecology), as documented in Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement, Ecology et al. 1989a) Change Control Form M-13-93-03 (Ecology et al. 1994) and a recent 200 NPL Agreement Change Control Form (Appendix A). The agreement also requires that, following completion of the activities described in thismore » test plan, a 200-BP-5 Operable Unit Interim Remedial Measure (IRM) Proposed Plan be developed for use in preparing an Interim Action Record of Decision (ROD). The IRM Proposed Plan will be supported by the results of this treatability test plan, as well as by other 200-BP-5 Operable Unit activities (e.g., development of a qualitative risk assessment). Once issued, the Interim Action ROD will specify the interim action(s) for groundwater contamination at the 200-BP-5 Operable Unit. The treatability test approach is to conduct a pilot-scale pump and treat test for each of the two contaminant plumes associated with the 200-BP-5 Operable Unit. Primary contaminants of concern are {sup 99}Tc and {sup 60}Co for underwater affected by past discharges to the 216-BY Cribs, and {sup 90}Sr, {sup 239/240}Pu, and Cs for groundwater affected by past discharges to the 216-B-5 Reverse Well. The purpose of the pilot-scale treatability testing presented in this testplan is to provide the data basis for preparing an IRM Proposed Plan. To achieve this objective, treatability testing must: Assess the performance of groundwater pumping with respect to the ability to extract a significant amount of the primary contaminant mass present in the two contaminant plumes.« less

  16. Railroad Redevelopment Planning.

    DTIC Science & Technology

    1981-01-01

    TEST CHART4A IONAL BUREAU’ Of STANDARDS- 1963-A -- m-ma REDQEVELcOPMENT PLANNIING *p W44 it -- 8 UNVRSITY OF C@O RAOO AT GENVER Tis docmr bpf Cr)o~d...officials began work on a set of guidelines in order to have some form of planned development u versus a piecemeal approach. According to a city...place. The city worked closely with various developers and their architects on the guidelines and the resulting ordinance was generally acceptable to

  17. [Statistical approach to evaluate the occurrence of out-of acceptable ranges and accuracy for antimicrobial susceptibility tests in inter-laboratory quality control program].

    PubMed

    Ueno, Tamio; Matuda, Junichi; Yamane, Nobuhisa

    2013-03-01

    To evaluate the occurrence of out-of acceptable ranges and accuracy of antimicrobial susceptibility tests, we applied a new statistical tool to the Inter-Laboratory Quality Control Program established by the Kyushu Quality Control Research Group. First, we defined acceptable ranges of minimum inhibitory concentration (MIC) for broth microdilution tests and inhibitory zone diameter for disk diffusion tests on the basis of Clinical and Laboratory Standards Institute (CLSI) M100-S21. In the analysis, more than two out-of acceptable range results in the 20 tests were considered as not allowable according to the CLSI document. Of the 90 participating laboratories, 46 (51%) experienced one or more occurrences of out-of acceptable range results. Then, a binomial test was applied to each participating laboratory. The results indicated that the occurrences of out-of acceptable range results in the 11 laboratories were significantly higher when compared to the CLSI recommendation (allowable rate < or = 0.05). The standard deviation indices(SDI) were calculated by using reported results, mean and standard deviation values for the respective antimicrobial agents tested. In the evaluation of accuracy, mean value from each laboratory was statistically compared with zero using a Student's t-test. The results revealed that 5 of the 11 above laboratories reported erroneous test results that systematically drifted to the side of resistance. In conclusion, our statistical approach has enabled us to detect significantly higher occurrences and source of interpretive errors in antimicrobial susceptibility tests; therefore, this approach can provide us with additional information that can improve the accuracy of the test results in clinical microbiology laboratories.

  18. Using the Integrated Vehicle Health Management Research Test and Integration Plan Wiki to Identify Synergistic Test Opportunities

    NASA Technical Reports Server (NTRS)

    Koelfgen, Syri J.; Faber, James J.

    2010-01-01

    The National Aeronautics and Space Administration (NASA) and the aviation industry have recognized a need for developing a method to identify and combine resources to carry out research and testing more efficiently. The Integrated Vehicle Health Management (IVHM) Research Test and Integration Plan (RTIP) Wiki is a tool that is used to visualize, plan, and accomplish collaborative research and testing. Synergistic test opportunities are developed using the RTIP Wiki, and include potential common resource testing that combines assets and personnel from NASA, industry, academia, and other government agencies. A research scenario is linked to the appropriate IVHM milestones and resources detailed in the wiki, reviewed by the research team members, and integrated into a collaborative test strategy. The scenario is then implemented by creating a test plan when appropriate and the research is performed. The benefits of performing collaborative research and testing are achieving higher Technology Readiness Level (TRL) test opportunities with little or no additional cost, improved quality of research, and increased communication among researchers. In addition to a description of the method of creating these joint research scenarios, examples of the successful development and implementation of cooperative research using the IVHM RTIP Wiki are given.

  19. The Unified Language Testing Plan: Speaking Proficiency Test. Russian Pilot Validation Studies. Report Number 2.

    ERIC Educational Resources Information Center

    Thornton, Julie A.

    The report describes one segment of the Federal Language Testing Board's Unified Language Testing Plan (ULTP), the validation of the speaking proficiency test in Russian. The ULTP is a project to increase standardization of foreign language proficiency measurement and promote sharing of resources among testing programs in the federal government.…

  20. The assessment of the impact of socio-economic factors in accepting cancer using the Acceptance of Illness Scale (AIS).

    PubMed

    Czerw, Aleksandra I; Bilińska, Magdalena; Deptała, Andrzej

    2016-01-01

    The paper presents the results of examining the level of acceptance of the illness in cancer patients using the Acceptance of Illness Scale (AIS). The study involved cancer patients treated at the Central Clinical Hospital of the Ministry the Interior in Warsaw in 2014. The questionnaire comprised basic demographic questions (socio-economic factors) and the AIS test estimating the level of illness acceptance in patients. For the group of patients in the research group, the arithmetic mean amounted to 27.56 points. The period of time that elapsed between the first cancer diagnosis and the start of the study did not influence the score of accepting illness. The acceptance of illness in patients diagnosed with metastases differed from the acceptance of illness by patients diagnosed with metastatic cancer. Females obtained the average of 29.59 in the AIS test, whereas the average in male patients was 26.17. The patients' age did not impact the AIS test. There were no differences in the AIS test results between a group of people with secondary education and a group of people with higher education. There were no differences in the AIS test results between employed individuals versus pensioners. The inhabitants of cities were characterized by the highest degree of acceptance of their health condition. The lowest degree of acceptance of illness was observed in the group with the lowest average incomes. In the group of married individuals the average degree of acceptance of illness amounted to 27.37 points. The average degree of acceptance of illness in patients that declared themselves as single amounted to 25.75. The average degree of acceptance of illness in the study group was 27.56 points, which is a relatively high level of acceptance of cancer. The main socio-economic factor, which influenced the AIS test results was whether metastases were diagnosed or not. There were no differences between patients in groups where the time that elapsed from the first diagnosis of

  1. Acceptability of woman-delivered HIV self-testing to the male partner, and additional interventions: a qualitative study of antenatal care participants in Malawi.

    PubMed

    Choko, Augustine Talumba; Kumwenda, Moses Kelly; Johnson, Cheryl Case; Sakala, Doreen Wongera; Chikalipo, Maria Chifuniro; Fielding, Katherine; Chikovore, Jeremiah; Desmond, Nicola; Corbett, Elizabeth Lucy

    2017-06-26

    considered overly disappointing for those who receive nothing. Phone call reminders were preferred to short messaging service. Woman-delivered HIV self-testing through ANC was acceptable to pregnant women and their male partners. Feedback on additional linkage enablers will be used to alter pre-planned trial arms.

  2. Test performance and acceptability of self- versus provider-collected swabs for high-risk HPV DNA testing in female-to-male trans masculine patients

    PubMed Central

    Deutsch, Madeline B.; Peitzmeier, Sarah M.; White Hughto, Jaclyn M.; Cavanaugh, Timothy P.; Pardee, Dana J.; McLean, Sarah A.; Panther, Lori A.; Gelman, Marcy; Mimiaga, Matthew J.; Potter, Jennifer E.

    2018-01-01

    Background High-risk human papillomavirus (hrHPV) causes virtually all cervical cancers. Trans masculine (TM) people (those assigned female at birth who identify with a gender other than female) have low uptake of conventional cervical cancer screening. Self-collected hrHPV DNA testing has high levels of acceptability among cisgender (non-transgender) females and may support increased cervical cancer screening uptake in TM individuals. Objective To assess the test performance and acceptability of self-collected vaginal specimens in comparison to provider-collected cervical swabs for hrHPV DNA detection in TM individuals ages 21–64 years. Methods Between March 2015-September 2016, 150 TM participants with a cervix (mean age = 27.5 years; SD = 5.7) completed a one-time study visit comprised of a self-report survey, self-collected vaginal HPV DNA swab, clinician-administered cervical HPV swab, and brief interview on acceptability of clinical procedures. Participants were randomized to complete either self- or provider-collection first to minimize ordering effects. Self- and provider-collected samples were tested for 13 hrHPV DNA types using a DNA Hybridization Assay. The primary outcome variable was the concordance (kappa statistic) and performance (sensitivity, specificity) of self-collected vaginal HPV DNA specimens versus provider-collected cervical HPV swabs as the gold standard. Results Of the 131 participants completing both the self- and provider-collected HPV tests, 21 cases of hrHPV were detected by the provider cervical swab (gold standard; 16.0% hrHPV prevalence); 15 of these cases were accurately detected by the self-collected vaginal swab (71.4% concordance) (Kappa = 0.75, 95% Confidence Interval [CI]: 0.59, 0.92; p<0.001). Compared to the provider-collected cervical hrHPV DNA sample (gold standard), the self-collected vaginal hrHPV DNA test demonstrated a sensitivity of 71.4% (95% CI: 0.52, 0.91; p = 0.0495) and specificity of 98.2% (95% CI: 0.96, 1

  3. Test performance and acceptability of self- versus provider-collected swabs for high-risk HPV DNA testing in female-to-male trans masculine patients.

    PubMed

    Reisner, Sari L; Deutsch, Madeline B; Peitzmeier, Sarah M; White Hughto, Jaclyn M; Cavanaugh, Timothy P; Pardee, Dana J; McLean, Sarah A; Panther, Lori A; Gelman, Marcy; Mimiaga, Matthew J; Potter, Jennifer E

    2018-01-01

    High-risk human papillomavirus (hrHPV) causes virtually all cervical cancers. Trans masculine (TM) people (those assigned female at birth who identify with a gender other than female) have low uptake of conventional cervical cancer screening. Self-collected hrHPV DNA testing has high levels of acceptability among cisgender (non-transgender) females and may support increased cervical cancer screening uptake in TM individuals. To assess the test performance and acceptability of self-collected vaginal specimens in comparison to provider-collected cervical swabs for hrHPV DNA detection in TM individuals ages 21-64 years. Between March 2015-September 2016, 150 TM participants with a cervix (mean age = 27.5 years; SD = 5.7) completed a one-time study visit comprised of a self-report survey, self-collected vaginal HPV DNA swab, clinician-administered cervical HPV swab, and brief interview on acceptability of clinical procedures. Participants were randomized to complete either self- or provider-collection first to minimize ordering effects. Self- and provider-collected samples were tested for 13 hrHPV DNA types using a DNA Hybridization Assay. The primary outcome variable was the concordance (kappa statistic) and performance (sensitivity, specificity) of self-collected vaginal HPV DNA specimens versus provider-collected cervical HPV swabs as the gold standard. Of the 131 participants completing both the self- and provider-collected HPV tests, 21 cases of hrHPV were detected by the provider cervical swab (gold standard; 16.0% hrHPV prevalence); 15 of these cases were accurately detected by the self-collected vaginal swab (71.4% concordance) (Kappa = 0.75, 95% Confidence Interval [CI]: 0.59, 0.92; p<0.001). Compared to the provider-collected cervical hrHPV DNA sample (gold standard), the self-collected vaginal hrHPV DNA test demonstrated a sensitivity of 71.4% (95% CI: 0.52, 0.91; p = 0.0495) and specificity of 98.2% (95% CI: 0.96, 1.00; p<0.0001). Over 90% of participants

  4. Front-end Electronics for Unattended Measurement (FEUM). Prototype Test Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conrad, Ryan C.; Morris, Scott J.; Smith, Leon E.

    2015-09-16

    The IAEA has requested that PNNL perform an initial set of tests on front-end electronics for unattended measurement (FEUM) prototypes. The FEUM prototype test plan details the tests to be performed, the criteria for evaluation, and the procedures used to execute the tests.

  5. Implementation and Operational Research: Effectiveness and Patient Acceptability of a Sexually Transmitted Infection Self-Testing Program in an HIV Care Setting.

    PubMed

    Barbee, Lindley A; Tat, Susana; Dhanireddy, Shireesha; Marrazzo, Jeanne M

    2016-06-01

    Rates of screening for bacterial sexually transmitted infections (STI) among men who have sex with men in HIV care settings remain low despite high prevalence of these infections. STI self-testing may help increase screening rates in clinical settings. We implemented an STI self-testing program at a large, urban HIV care clinic and evaluated its effectiveness and acceptability. We compared measures obtained during the first year of the STI self-testing program (Intervention Year, April 1, 2013-March 31, 2014) to Baseline Year (January 1, 2012-December 31, 2012) to determine: (1) overall clinic change in STI testing coverage and diagnostic yield and; (2) program-specific outcomes including appropriate anatomic site screening and patient-reported acceptability. Overall, testing for gonorrhea and chlamydia increased significantly between Baseline and Intervention Year, and 50% more gonococcal and 47% more chlamydial infections were detected. Syphilis testing coverage remained unchanged. Nearly 95% of 350 men who participated in the STI self-testing program completed site-specific testing appropriately based on self-reported exposures, and 92% rated their self-testing experience as "good" or "very good." STI self-testing in HIV care settings significantly increases testing coverage and detection of gonorrhea and chlamydia, and the program is acceptable to patients. Additional interventions to increase syphilis screening rates are needed.

  6. Integrated test plan for directional boring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Volk, B.W.

    This integrated test plan describes the field testing of the DITCH WITCH Directional Boring System. DITCH WITCH is a registered trademark of The Charles Machine Works, Inc., Perry, Oklahoma. The test is being conducted as a coordinated effort between Charles Machine Works (CMW), Sandia National Laboratories (SNL), and the Westinghouse Hanford Company (WHC). Funding for the WHC portion of the project is through the Volatile Organic Compound-Arid Integrated Demonstration (VOC-Arid ID). The purpose of the test is to evaluate the performance of the directional boring system for possible future use on environmental restoration projects at Hanford and other Department ofmore » Energy (DOE) sites. The test will be conducted near the 200 Areas Fire Station located between the 200 East and 200 West Area of the Hanford Site. The directional boring system will be used to drill and complete (with fiberglass casing) two horizontal boreholes. A third borehole will be drilled to test sampling equipment but will not be completed with casing.« less

  7. Gerontechnology acceptance by elderly Hong Kong Chinese: a senior technology acceptance model (STAM).

    PubMed

    Chen, Ke; Chan, Alan Hoi Shou

    2014-01-01

    The purpose of this study was to develop and test a senior technology acceptance model (STAM) aimed at understanding the acceptance of gerontechnology by older Hong Kong Chinese people. The proposed STAM extended previous technology acceptance models and theories by adding age-related health and ability characteristics of older people. The proposed STAM was empirically tested using a cross-sectional questionnaire survey with a sample of 1012 seniors aged 55 and over in Hong Kong. The result showed that STAM was strongly supported and could explain 68% of the variance in the use of gerontechnology. For older Hong Kong Chinese, individual attributes, which include age, gender, education, gerontechnology self-efficacy and anxiety, and health and ability characteristics, as well as facilitating conditions explicitly and directly affected technology acceptance. These were better predictors of gerontechnology usage behaviour (UB) than the conventionally used attitudinal factors (usefulness and ease of use).

  8. Test and Evaluation for Enhanced Security: A Quantitative Method to Incorporate Expert Knowledge into Test Planning Decisions.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rizzo, Davinia; Blackburn, Mark

    Complex systems are comprised of technical, social, political and environmental factors as well as the programmatic factors of cost, schedule and risk. Testing these systems for enhanced security requires expert knowledge in many different fields. It is important to test these systems to ensure effectiveness, but testing is limited to due cost, schedule, safety, feasibility and a myriad of other reasons. Without an effective decision framework for Test and Evaluation (T&E) planning that can take into consideration technical as well as programmatic factors and leverage expert knowledge, security in complex systems may not be assessed effectively. Therefore, this paper coversmore » the identification of the current T&E planning problem and an approach to include the full variety of factors and leverage expert knowledge in T&E planning through the use of Bayesian Networks (BN).« less

  9. Improved Test Planning and Analysis Through the Use of Advanced Statistical Methods

    NASA Technical Reports Server (NTRS)

    Green, Lawrence L.; Maxwell, Katherine A.; Glass, David E.; Vaughn, Wallace L.; Barger, Weston; Cook, Mylan

    2016-01-01

    The goal of this work is, through computational simulations, to provide statistically-based evidence to convince the testing community that a distributed testing approach is superior to a clustered testing approach for most situations. For clustered testing, numerous, repeated test points are acquired at a limited number of test conditions. For distributed testing, only one or a few test points are requested at many different conditions. The statistical techniques of Analysis of Variance (ANOVA), Design of Experiments (DOE) and Response Surface Methods (RSM) are applied to enable distributed test planning, data analysis and test augmentation. The D-Optimal class of DOE is used to plan an optimally efficient single- and multi-factor test. The resulting simulated test data are analyzed via ANOVA and a parametric model is constructed using RSM. Finally, ANOVA can be used to plan a second round of testing to augment the existing data set with new data points. The use of these techniques is demonstrated through several illustrative examples. To date, many thousands of comparisons have been performed and the results strongly support the conclusion that the distributed testing approach outperforms the clustered testing approach.

  10. Regional planning acceptance by residents of Northern New York, USA

    NASA Astrophysics Data System (ADS)

    Bobrow, Patricia; Gaige, Barbara; Harris, Glenn; Kennedy, Joyce; King, Leslie; Raymond, William; Werbitsky, Darrin

    1984-01-01

    This study compares the effectiveness of two regional planning agencies in terms of public support for various planning activities. The Adirondack Park Agency and the Temporary State Commission on Tug Hill have fundamentally different approaches to planning. The Adirondack Park Agency has implemented a restrictive regulatory program with little citizen participation by Adirondack residents. The Tug Hill Commission has implemented an advisory and coordinating program with an emphasis on public input. Residents of two towns in each region were surveyed to determine environmental concern and support for regional planning activities. Respondents from both regions favored a planning agency that incorporates citizen input; controls air, water, and toxic waste pollution; and develops recreation areas. They strongly opposed an agency that regulates private land-use. Basic demographic characteristics and levels of environmental concern were similar in all four towns, but receptivity to various planning activities was consistently greater among residents of the Tug Hill Region. Paired comparisons of the four towns demonstrated no differences between towns of the same region and significant differences between towns of different regions. Public support for regional planning is greater in the Tug Hill Region than in the Adirondack Park.

  11. Validity and Acceptance of Color Vision Testing on Smartphones.

    PubMed

    Ozgur, Omar K; Emborgo, Trisha S; Vieyra, Mark B; Huselid, Rebecca F; Banik, Rudrani

    2018-03-01

    Ishihara color plates (ICP) are the most commonly used color vision test (CVT) worldwide. With the advent of new technologies, attempts have been made to streamline the process of CVT. As hardware and software evolve, smartphone-based testing modalities may aid ophthalmologists in performing more efficient ophthalmic examinations. We assess the validity of smartphone color vision testing (CVT) by comparing results using the Eye Handbook (EHB) CVT application with standard Ishihara color plates (ICP). Prospective case-control study of subjects 18 years and older with visual acuity of 20/100 or better at 14 inches. The study group included patients with any ocular pathology. The color vision deficient (CVD) group was patients who failed more than 2 plates. The control group had no known ocular pathology. CVT was performed with both ICP and EHB under standardized background illuminance. Eleven plates were tested with each modality. Validity of EHB CVT and acceptance of EHB CVT were analyzed. Statistical analyses were performed using Bland-Altman plot with limits of agreement (LOA) at the 95th percentile of differences in score, independent samples t tests with 95% confidence interval (CI), and Pearson χ tests. The Bland-Altman plot showed agreement between correct number of plates in EHB and ICP for the study subjects (bias, -0.25; LOA, -1.92 to 1.42). Agreement was also observed between the correct number of plates in EHB and ICP for the controls (bias, -0.01; LOA, -0.61 to 0.59) and CVD (bias, -0.50; LOA, -4.64 to 3.64) subjects. The sensitivity of EHB was 0.92 (95% CI 0.76-1.07) and the specificity of EHB was 1.00 (95% CI 1.00-1.00). Fifty-nine percent preferred EHB, 12% preferred ICP, and 29% had no preference. In healthy controls and patients with ocular pathology, there was an agreement of CVT results comparing EHB with ICP. Overall, the majority preferred EHB to ICP. These findings demonstrate that further testing is required to understand and improve the

  12. Consumer acceptance of vegetarian sweet potato products intended for space missions.

    PubMed

    Wilson, C D; Pace, R D; Bromfield, E; Jones, G; Lu, J Y

    1998-01-01

    Sweet potato is one of the crops selected for NASA's Advanced Life Support Program for potential long-duration lunar/Mars missions. This article presents recipes of products made from sweet potato and determines the consumer acceptability of products containing from 6% to 20% sweet potato on a dry weight basis. These products were developed for use in nutritious and palatable meals for future space explorers. Sensory evaluation (appearance/color, aroma, texture, flavor/taste, and overall acceptability) studies were conducted to determine the consumer acceptability of vegetarian products made with sweet potato using panelists at NASA/Johnson Space Center in Houston, TX. None of these products including the controls, contained any ingredient of animal origin with the exception of sweet potato pie. A 9-point hedonic scale (9 being like extremely and 1 being dislike extremely) was used to evaluate 10 products and compare them to similar commercially available products used as controls. The products tested were pancakes, waffles, tortillas, bread, pie, pound cake, pasta, vegetable patties, doughnuts, and pretzels. All of the products were either liked moderately or liked slightly with the exception of the sweet potato vegetable patties, which were neither liked nor disliked. Mean comparisons of sensory scores of sweet potato recipes and their controls were accomplished by using the Student t-test. Because of their nutritional adequacy and consumer acceptability, these products are being recommended to NASA's Advanced Life Support Program for inclusion in a vegetarian menu plan designed for lunar/Mars space missions.

  13. Hazardous material transportation safety and security field operational test final detailed test plans : executive summary

    DOT National Transportation Integrated Search

    2003-09-16

    The objective of this Hazardous Material (HazMat) Transportation Safety and Security Field Operational Test (FOT) Final Detailed Test Plans evaluation is to measure the impact of technology solutions on the safety, security, and operational efficienc...

  14. EPRI/DOE High Burnup Fuel Sister Pin Test Plan Simplification and Visualization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saltzstein, Sylvia J.; Sorenson, Ken B.; Hanson, Brady

    The EPRI/DOE High Burnup Confirmatory Data Project (herein called the "Demo") is a multi-year, multi-entity confirmation demonstration test with the purpose of providing quantitative and qualitative data to show how high-burnup fuel ages in dry storage over a ten-year period. The Demo involves obtaining 32 assemblies of high-burnup PWR fuel of four common cladding alloys from the North Anna Nuclear Power Plant, drying them according to standard plant procedures, and then storing them in an NRC-licensed TN-3 2B cask on the North Anna dry storage pad for ten years. After the ten-year storage time, the cask will be opened andmore » the rods will be examined for signs of aging. Twenty-five rods from assemblies of similar claddings, in-reactor placement, and burnup histories (herein called "sister rods") have been shipped from the North Anna Nuclear Power Plant and are currently being nondestructively tested at Oak Ridge National Laboratory. After the non-destructive testing has been completed for each of the twenty-five rods, destructive analysis will be performed at ORNL, PNNL, and ANL to obtain mechanical data. Opinions gathered from the expert interviews, ORNL and PNNL Sister Rod Test Plans, and numerous meetings has resulted in the Simplified Test Plan described in this document. Some of the opinions and discussions leading to the simplified test plan are included here. Detailed descriptions and background are in the ORNL and PNNL plans in the appendices . After the testing described in this simplified test plan h as been completed , the community will review all the collected data and determine if additional testing is needed.« less

  15. Social trust, risk perceptions and public acceptance of recycled water: testing a social-psychological model.

    PubMed

    Ross, Victoria L; Fielding, Kelly S; Louis, Winnifred R

    2014-05-01

    Faced with a severe drought, the residents of the regional city of Toowoomba, in South East Queensland, Australia were asked to consider a potable wastewater reuse scheme to supplement drinking water supplies. As public risk perceptions and trust have been shown to be key factors in acceptance of potable reuse projects, this research developed and tested a social-psychological model of trust, risk perceptions and acceptance. Participants (N = 380) were surveyed a few weeks before a referendum was held in which residents voted against the controversial scheme. Analysis using structural equation modelling showed that the more community members perceived that the water authority used fair procedures (e.g., consulting with the community and providing accurate information), the greater their sense of shared identity with the water authority. Shared social identity in turn influenced trust via increased source credibility, that is, perceptions that the water authority is competent and has the community's interest at heart. The findings also support past research showing that higher levels of trust in the water authority were associated with lower perceptions of risk, which in turn were associated with higher levels of acceptance, and vice versa. The findings have a practical application for improving public acceptance of potable recycled water schemes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. The Space Station Photovoltaic Panels Plasma Interaction Test Program: Test plan and results

    NASA Technical Reports Server (NTRS)

    Nahra, Henry K.; Felder, Marian C.; Sater, Bernard L.; Staskus, John V.

    1989-01-01

    The Plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

  17. The Space Station photovoltaic panels plasma interaction test program - Test plan and results

    NASA Technical Reports Server (NTRS)

    Nahra, Henry K.; Felder, Marian C.; Sater, Bernard L.; Staskus, John V.

    1990-01-01

    The plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

  18. Engineering Task Plan for the Ultrasonic Inspection of Hanford Double Shell Tanks (DST) FY2000

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    JENSEN, C.E.

    2000-01-10

    This document facilitates the ultrasonic examination of Hanford double-shell tanks. Included are a plan for engineering activities (individual responsibilities), plan for performance demonstration testing, and a plan for field activities (tank inspection). Also included are a Statement of Work for contractor performance of the work and a protocol to be followed should tank flaws that exceed the acceptance criteria be discovered.

  19. The Feasibility and Acceptability of “Arise”: An Online Substance Abuse Relapse Prevention Program

    PubMed Central

    Bartel, Chelsea M.

    2015-01-01

    Abstract Objective: The purpose of this study was to test the feasibility and acceptability of a novel online adolescent substance abuse relapse prevention tool, “Arise” (3C Institute, Cary, NC). The program uses an innovative platform including interactive instructional segments and skill-building games to help adolescents learn and practice coping skills training strategies. Materials and Methods: We conducted a pilot test with nine adolescents in substance abuse treatment (44 percent female) and a feasibility test with treatment providers (n=8; 50 percent female). Adolescents interacted with the program via a secure Web site for approximately 30 minutes for each of two instructional units. Treatment providers reviewed the same material at their own pace. All participants completed a questionnaire with items assessing usability, acceptability, understanding, and subjective experience of the program. Results: Regarding feasibility, recruitment of this population within the study constraints proved challenging, but participant retention in the trial was high (no attrition). Adolescents and treatment providers completed the program with no reported problems, and overall we were able to collect data as planned. Regarding acceptability, the program received strong ratings from both adolescents and providers, who found the prototype informative, engaging, and appealing. Both groups strongly recommended continuing development. Conclusions: We were able to deliver the intervention as intended, and acceptability ratings were high, demonstrating the feasibility and acceptability of online delivery of engaging interactive interventions. This study contributes to our understanding of how interactive technologies, including games, can be used to modify behavior in substance abuse treatment and other health areas. PMID:26181807

  20. 16 CFR 1616.4 - Sampling and acceptance procedures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... specimen to one of the three samples. Test each set of three samples and accept or reject each seam design... all the test criteria of § 1616.3(b), accept the seam design. If one or more of the three additional.... Test the sets of three samples and accept or reject the type of trim and design on the same basis as...

  1. 16 CFR 1616.4 - Sampling and acceptance procedures.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... specimen to one of the three samples. Test each set of three samples and accept or reject each seam design... all the test criteria of § 1616.3(b), accept the seam design. If one or more of the three additional.... Test the sets of three samples and accept or reject the type of trim and design on the same basis as...

  2. 16 CFR 1616.4 - Sampling and acceptance procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... specimen to one of the three samples. Test each set of three samples and accept or reject each seam design... all the test criteria of § 1616.3(b), accept the seam design. If one or more of the three additional.... Test the sets of three samples and accept or reject the type of trim and design on the same basis as...

  3. 48 CFR 1311.103 - Market acceptance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Market acceptance. 1311.103 Section 1311.103 Federal Acquisition Regulations System DEPARTMENT OF COMMERCE COMPETITION AND ACQUISITION PLANNING DESCRIBING AGENCY NEEDS Selecting and Developing Requirements Documents 1311.103 Market...

  4. 48 CFR 811.103 - Market acceptance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Market acceptance. 811.103 Section 811.103 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS COMPETITION AND ACQUISITION PLANNING DESCRIBING AGENCY NEEDS Selecting and Developing Requirements Documents 811.103 Market...

  5. 48 CFR 1011.103 - Market Acceptance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Market Acceptance. 1011.103 Section 1011.103 Federal Acquisition Regulations System DEPARTMENT OF THE TREASURY COMPETITION AND ACQUISITION PLANNING DESCRIBING AGENCY NEEDS Selecting and Developing Requirements Documents 1011.103 Market...

  6. The Acceptance Strategy for Nuclear Power Plant In Indonesia

    NASA Astrophysics Data System (ADS)

    Suhaemi, Tjipta; Syaukat, Achmad

    2010-06-01

    THE ACCEPTANCE STRATEGY FOR NUCLEAR POWER PLANT IN INDONESIA. Indonesia has planned to build nuclear power plants. Some feasibility studies have been conducted intensively. However, the processes of NPP introduction are still uncertain. National Energy Plan in Indonesia, which has been made by some governmental agencies, does not yet give positive impact to the government decision to construct the nuclear power plant (NPP). This paper discusses the process of NPP introduction in Indonesia, which has been colored with debate of stakeholder and has delayed decision for go-nuclear. The technology paradigm is used to promote NPP as an alternative of reliable energy resources. This paradigm should be complemented with international politic-economic point of view. The international politic-economic point of view shows that structural powers, consisting of security, production, finance, and knowledge structures, within which the NPP is introduced, have dynamic characteristics. The process of NPP introduction in Indonesia contains some infrastructure development (R&D, legislation, regulation, energy planning, site study, public acceptance efforts, etc), but they need a better coherent NPP implementation program and NPP Acceptance Program. Strategic patterns for NPP acceptance described in this paper are made by considering nuclear regulation development and the interest of basic domestic participation. The first NPP program in Indonesia having proven technology and basic domestic participation is and important milestone toward and optimal national energy-mix.

  7. Test Plan for SSR Antenna Rotation Rate Stabilization

    DOT National Transportation Integrated Search

    1981-10-01

    A comprehensive test plan is presented to evaluate the impact of wind and ice loading on the rotation rate stability of a Secondary Surveillance Radar (SSR) antenna used for air traffic control surveillance. Antenna rotation rate variations may intro...

  8. Underground Test Area Subproject Project Management Plan, Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-06-03

    This Project Management Plan (PMP) describes the manner in which the US Department of Energy Nevada Operations Office (DOE/NV) will manage the Underground Test Area (UGTA) Subproject at the Nevada Test Site (NTS). It provides the basic guidance for implementation and the organizational structure for meeting the UGTA objectives.

  9. Performance of the JT-60SA cryogenic system under pulsed heat loads during acceptance tests

    NASA Astrophysics Data System (ADS)

    Hoa, C.; Bonne, F.; Roussel, P.; Lamaison, V.; Girard, S.; Fejoz, P.; Goncalves, R.; Vallet, J. C.; Legrand, J.; Fabre, Y.; Pudys, V.; Wanner, M.; Cardella, A.; Di Pietro, E.; Kamiya, K.; Natsume, K.; Ohtsu, K.; Oishi, M.; Honda, A.; Kashiwa, Y.; Kizu, K.

    2017-12-01

    The JT-60SA cryogenic system a superconducting tokamak currently under assembly at Naka, Japan. After one year of commissioning, the acceptance tests were successfully completed in October 2016 in close collaboration with Air Liquide Advanced Technologies (ALaT), the French atomic and alternative energies commission (CEA), Fusion for Energy (F4E) and the Quantum Radiological Science and Technology (QST). The cryogenic system has several cryogenic users at various temperatures: the superconducting magnets at 4.4 K, the current leads at 50 K, the thermal shields at 80 K and the divertor cryo-pumps at 3.7 K. The cryogenic system has an equivalent refrigeration power of about 9.5 kW at 4.5 K, with peak loads caused by the nuclear heating, the eddy currents in the structures and the AC losses in the magnets during cyclic plasma operation. The main results of the acceptance tests will be reported, with emphasis on the management of the challenging pulsed load operation using a liquid helium volume of 7 m3 as a thermal damper.

  10. Atmospheric Reentry Materials and Structures Evaluation Facility (ARMSEF). User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the ARMSEF. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  11. Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review.

    PubMed

    Ratter, Julia; Radlinger, Lorenz; Lucas, Cees

    2014-09-01

    Are submaximal and maximal exercise tests reliable, valid and acceptable in people with chronic pain, fibromyalgia and fatigue disorders? Systematic review of studies of the psychometric properties of exercise tests. People older than 18 years with chronic pain, fibromyalgia and chronic fatigue disorders. Studies of the measurement properties of tests of physical capacity in people with chronic pain, fibromyalgia or chronic fatigue disorders were included. Studies were required to report: reliability coefficients (intraclass correlation coefficient, alpha reliability coefficient, limits of agreements and Bland-Altman plots); validity coefficients (intraclass correlation coefficient, Spearman's correlation, Kendal T coefficient, Pearson's correlation); or dropout rates. Fourteen studies were eligible: none had low risk of bias, 10 had unclear risk of bias and four had high risk of bias. The included studies evaluated: Åstrand test; modified Åstrand test; Lean body mass-based Åstrand test; submaximal bicycle ergometer test following another protocol other than Åstrand test; 2-km walk test; 5-minute, 6-minute and 10-minute walk tests; shuttle walk test; and modified symptom-limited Bruce treadmill test. None of the studies assessed maximal exercise tests. Where they had been tested, reliability and validity were generally high. Dropout rates were generally acceptable. The 2-km walk test was not recommended in fibromyalgia. Moderate evidence was found for reliability, validity and acceptability of submaximal exercise tests in patients with chronic pain, fibromyalgia or chronic fatigue. There is no evidence about maximal exercise tests in patients with chronic pain, fibromyalgia and chronic fatigue. Copyright © 2014. Published by Elsevier B.V.

  12. The Advantages of Using Planned Comparisons over Post Hoc Tests.

    ERIC Educational Resources Information Center

    Kuehne, Carolyn C.

    There are advantages to using a priori or planned comparisons rather than omnibus multivariate analysis of variance (MANOVA) tests followed by post hoc or a posteriori testing. A small heuristic data set is used to illustrate these advantages. An omnibus MANOVA test was performed on the data followed by a post hoc test (discriminant analysis). A…

  13. WE-DE-201-04: Cross Validation of Knowledge-Based Treatment Planning for Prostate LDR Brachytherapy Using Principle Component Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roper, J; Ghavidel, B; Godette, K

    Purpose: To validate a knowledge-based algorithm for prostate LDR brachytherapy treatment planning. Methods: A dataset of 100 cases was compiled from an active prostate seed implant service. Cases were randomized into 10 subsets. For each subset, the 90 remaining library cases were registered to a common reference frame and then characterized on a point by point basis using principle component analysis (PCA). Each test case was converted to PCA vectors using the same process and compared with each library case using a Mahalanobis distance to evaluate similarity. Rank order PCA scores were used to select the best-matched library case. Themore » seed arrangement was extracted from the best-matched case and used as a starting point for planning the test case. Any subsequent modifications were recorded that required input from a treatment planner to achieve V100>95%, V150<60%, V200<20%. To simulate operating-room planning constraints, seed activity was held constant, and the seed count could not increase. Results: The computational time required to register test-case contours and evaluate PCA similarity across the library was 10s. Preliminary analysis of 2 subsets shows that 9 of 20 test cases did not require any seed modifications to obtain an acceptable plan. Five test cases required fewer than 10 seed modifications or a grid shift. Another 5 test cases required approximately 20 seed modifications. An acceptable plan was not achieved for 1 outlier, which was substantially larger than its best match. Modifications took between 5s and 6min. Conclusion: A knowledge-based treatment planning algorithm for prostate LDR brachytherapy is being cross validated using 100 prior cases. Preliminary results suggest that for this size library, acceptable plans can be achieved without planner input in about half of the cases while varying amounts of planner input are needed in remaining cases. Computational time and planning time are compatible with clinical practice.« less

  14. Test, Control and Monitor System (TCMS) operations plan

    NASA Technical Reports Server (NTRS)

    Macfarlane, C. K.; Conroy, M. P.

    1993-01-01

    The purpose is to provide a clear understanding of the Test, Control and Monitor System (TCMS) operating environment and to describe the method of operations for TCMS. TCMS is a complex and sophisticated checkout system focused on support of the Space Station Freedom Program (SSFP) and related activities. An understanding of the TCMS operating environment is provided and operational responsibilities are defined. NASA and the Payload Ground Operations Contractor (PGOC) will use it as a guide to manage the operation of the TCMS computer systems and associated networks and workstations. All TCMS operational functions are examined. Other plans and detailed operating procedures relating to an individual operational function are referenced within this plan. This plan augments existing Technical Support Management Directives (TSMD's), Standard Practices, and other management documentation which will be followed where applicable.

  15. 7. PHOTOCOPY, PLANS, ELEVATIONS, AND SECTION DRAWING FOR MISSILE TEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. PHOTOCOPY, PLANS, ELEVATIONS, AND SECTION DRAWING FOR MISSILE TEST AND ASSEMBLY BUILDING. - NIKE Missile Base SL-40, Missile Test & Assembly Building, South end of launch area, northeast of Generator Building No. 3, Hecker, Monroe County, IL

  16. Large-acceptance diamond planar refractive lenses manufactured by laser cutting.

    PubMed

    Polikarpov, Maxim; Snigireva, Irina; Morse, John; Yunkin, Vyacheslav; Kuznetsov, Sergey; Snigirev, Anatoly

    2015-01-01

    For the first time, single-crystal diamond planar refractive lenses have been fabricated by laser micromachining in 300 µm-thick diamond plates which were grown by chemical vapour deposition. Linear lenses with apertures up to 1 mm and parabola apex radii up to 500 µm were manufactured and tested at the ESRF ID06 beamline. The large acceptance of these lenses allows them to be used as beam-conditioning elements. Owing to the unsurpassed thermal properties of single-crystal diamond, these lenses should be suitable to withstand the extreme flux densities expected at the planned fourth-generation X-ray sources.

  17. Mobile computing acceptance factors in the healthcare industry: a structural equation model.

    PubMed

    Wu, Jen-Her; Wang, Shu-Ching; Lin, Li-Min

    2007-01-01

    This paper presents a revised technology acceptance model to examine what determines mobile healthcare systems (MHS) acceptance by healthcare professionals. Conformation factor analysis was performed to test the reliability and validity of the measurement model. The structural equation modeling technique was used to evaluate the causal model. The results indicated that compatibility, perceived usefulness and perceived ease of use significantly affected healthcare professional behavioral intent. MHS self-efficacy had strong indirect impact on healthcare professional behavioral intent through the mediators of perceived usefulness and perceived ease of use. Yet, the hypotheses for technical support and training effects on the perceived usefulness and perceived ease of use were not supported. This paper provides initial insights into factors that are likely to be significant antecedents of planning and implementing mobile healthcare to enhance professionals' MHS acceptance. The proposed model variables explained 70% of the variance in behavioral intention to use MHS; further study is needed to explore extra significant antecedents of new IT/IS acceptance for mobile healthcare. Such as privacy and security issue, system and information quality, limitations of mobile devices; the above may be other interesting factors for implementing mobile healthcare and could be conducted by qualitative research.

  18. EBMUD Drought Planning Put to the Test in 2014

    NASA Astrophysics Data System (ADS)

    Bray, B. S.

    2014-12-01

    The East Bay Municipal Utility District faced challenges in the unprecedented 2014 drought managing limited supplies to reliably serve its customers. The District's successful drought planning required a multi-faceted plan to preserve a reliable water supply, now and into the future. Planning has included investments in recycled water projects, passive and active customer conservation programs, and pursuit of alternative water supply options. EBMUD's drought planning efforts have been tested in 2014 when California experienced one of the driest years on record and the 2nd driest year in the Mokelumne Watershed, the source of 90% of the District's water supply. This presentation will highlight the effectiveness of drought planning in three areas: (1) implementing 10% water conservation as of July 2014, (2) the securing of nearly 20TAF of supplemental water supply conveyed through the Freeport Regional Water Project, and (3) operating EBMUD's Mokelumne River Project to meet fishery flow and water quality objectives.

  19. Continual planning and scheduling for managing patient tests in hospital laboratories.

    PubMed

    Marinagi, C C; Spyropoulos, C D; Papatheodorou, C; Kokkotos, S

    2000-10-01

    Hospital laboratories perform examination tests upon patients, in order to assist medical diagnosis or therapy progress. Planning and scheduling patient requests for examination tests is a complicated problem because it concerns both minimization of patient stay in hospital and maximization of laboratory resources utilization. In the present paper, we propose an integrated patient-wise planning and scheduling system which supports the dynamic and continual nature of the problem. The proposed combination of multiagent and blackboard architecture allows the dynamic creation of agents that share a set of knowledge sources and a knowledge base to service patient test requests.

  20. WEC-SIM Validation Testing Plan FY14 Q4.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruehl, Kelley Michelle

    2016-02-01

    The WEC-Sim project is currently on track, having met both the SNL and NREL FY14 Milestones, as shown in Table 1 and Table 2. This is also reflected in the Gantt chart uploaded to the WEC-Sim SharePoint site in the FY14 Q4 Deliverables folder. The work completed in FY14 includes code verification through code-to-code comparison (FY14 Q1 and Q2), preliminary code validation through comparison to experimental data (FY14 Q2 and Q3), presentation and publication of the WEC-Sim project at OMAE 2014 [1], [2], [3] and GMREC/METS 2014 [4] (FY14 Q3), WEC-Sim code development and public open-source release (FY14 Q3), andmore » development of a preliminary WEC-Sim validation test plan (FY14 Q4). This report presents the preliminary Validation Testing Plan developed in FY14 Q4. The validation test effort started in FY14 Q4 and will go on through FY15. Thus far the team has developed a device selection method, selected a device, and placed a contract with the testing facility, established several collaborations including industry contacts, and have working ideas on the testing details such as scaling, device design, and test conditions.« less

  1. Women's career priority is associated with attitudes towards family planning and ethical acceptance of reproductive technologies.

    PubMed

    Simoni, Michael K; Mu, Lin; Collins, Stephen C

    2017-10-01

    Do women who place high importance on career success have different perceptions of pregnancy planning, delayed reproduction, and the ethical acceptability of ART than women with less emphasis on their career? Career-focused women place more importance on pregnancy planning, have greater confidence in delayed childbearing, and are more ethically accepting of donor gamete ART than women who do not place as much importance on career success. Women in high-professional careers are more likely to delay childbearing while simultaneously possessing a stronger desire for motherhood. The underlying values which enable these competing desires have not been elucidated. This cross-sectional study utilized data from the National Survey of Fertility Barriers (NSFB), a nationally representative telephone survey of US women aged 25-45. Funded by the Eunice Kennedy Shriver National Institute of Child Health and Human Development, the NSFB surveyed 4712 women from 2004 to 2007. In addition to demographic data, the NSFB obtained information about the reproductive history and personal values of participants. Weighted multivariate regression analysis was used to assess reproductive values in career-focused women. In total, 48.8% of women considered success in work very important, while 17.3% considered it somewhat or not important. Women who placed less value on career success were less likely to consider pregnancy planning important and were less optimistic about the success of delayed childbearing than their work-centric counterparts. Women less focused on their careers were also more likely to have serious ethical concerns about donor gametes, but less likely to have ethical concerns about IUI or IVF, when compared to career-focused women. Intention to bear children could not be evaluated in the setting of career intentions due to a lack of data on when the participant intended on pursuing motherhood. Political preferences on reproductive health were also not evaluated. The validity

  2. Water NSTF Design, Instrumentation, and Test Planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lisowski, Darius D.; Gerardi, Craig D.; Hu, Rui

    The following report serves as a formal introduction to the water-based Natural convection Shutdown heat removal Test Facility (NSTF) program at Argonne. Since 2005, this US Department of Energy (DOE) sponsored program has conducted large scale experimental testing to generate high-quality and traceable validation data for guiding design decisions of the Reactor Cavity Cooling System (RCCS) concept for advanced reactor designs. The most recent facility iteration, and focus of this report, is the operation of a 1/2 scale model of a water-RCCS concept. Several features of the NSTF prototype align with the conceptual design that has been publicly released formore » the AREVA 625 MWt SC-HTGR. The design of the NSTF also retains all aspects common to a fundamental boiling water thermosiphon, and thus is well poised to provide necessary experimental data to advance basic understanding of natural circulation phenomena and contribute to computer code validation. Overall, the NSTF program operates to support the DOE vision of aiding US vendors in design choices of future reactor concepts, advancing the maturity of codes for licensing, and ultimately developing safe and reliable reactor technologies. In this report, the top-level program objectives, testing requirements, and unique considerations for the water cooled test assembly are discussed, and presented in sufficient depth to support defining the program’s overall scope and purpose. A discussion of the proposed 6-year testing program is then introduced, which outlines the specific strategy and testing plan for facility operations. The proposed testing plan has been developed to meet the toplevel objective of conducting high-quality test operations that span across a broad range of single- and two-phase operating conditions. Details of characterization, baseline test cases, accident scenario, and parametric variations are provided, including discussions of later-stage test cases that examine the influence of

  3. Test Plan for the Technology Maturation of Supersonic Inflatable Aerodynamic Decelerators

    NASA Technical Reports Server (NTRS)

    Kelly, Jenny R.; Cruz, Juan R.

    2009-01-01

    Supersonic inflatable aerodynamic decelerators (IADs) are drag devices intended to be deployed at high Mach numbers. In the application considered here they assist in the descent and landing of spacecraft on Mars. Although promising, present IAD technology is not yet sufficiently mature for use in the near future. This paper describes a technology maturation plan for tension cone IADs using subscale test articles to reduce development costs. As envisioned, the proposed test plan includes three phases: wind tunnel tests (subsonic), unpowered high-altitude flight tests (transonic), and powered high-altitude tests (supersonic). This test plan is based on a building block approach in which successful completion of each phase adds to the understanding of the behavior of IADs and reduces the risk of the subsequent, more expensive phases. By properly scaling the IADs, test articles of the same size and nearly the same construction can be used for all three phases. The final phase is a dynamically scaled flight test with IAD deployment at the same Mach number as the full-scale vehicle on Mars. Two full-scale example cases are presented: one for a single-stage system (15 m dia. IAD to subsonic retropropulsion), and another for a two-stage system (10.5 m dia. IAD to subsonic parachute). Using scale factors of 0.333 and 0.476 yield subscale test IADs of 5 m dia. The dynamically scaled powered flight test starts at Mach 4 and an altitude of 33.5 km. Existing balloons and rocket motors are shown to be adequate to meet the required test conditions.

  4. 30 CFR 879.13 - Acceptance of gifts of land.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Acceptance of gifts of land. 879.13 Section 879... Acceptance of gifts of land. (a) The OSM, State, or Indian tribe under an approved reclamation plan may... requirements set out in § 879.11. (b) Offers to make a gift of land or interest in land to the U.S. Government...

  5. Field Test of Route Planning Software for Lunar Polar Missions

    NASA Astrophysics Data System (ADS)

    Horchler, A. D.; Cunningham, C.; Jones, H. L.; Arnett, D.; Fang, E.; Amoroso, E.; Otten, N.; Kitchell, F.; Holst, I.; Rock, G.; Whittaker, W.

    2017-10-01

    A novel field test paradigm has been developed to demonstrate and validate route planning software in the stark low-angled light and sweeping shadows a rover would experience at the poles of the Moon. Software, ConOps, and test results are presented.

  6. Safety and Acceptability of Couples HIV Testing and Counseling for US Men Who Have Sex with Men: A Randomized Prevention Study

    PubMed Central

    Sullivan, Patrick S.; White, Darcy; Rosenberg, Eli S.; Barnes, Jasper; Jones, Jeb; Dasgupta, Sharoda; O’Hara, Brandon; Scales, Lamont; Salazar, Laura F.; Wingood, Gina; DiClemente, Ralph; Wall, Kristin M.; Hoff, Colleen; Gratzer, Beau; Allen, Susan; Stephenson, Rob

    2013-01-01

    We tested a couples HIV testing and counseling (CHTC) intervention with male couples in Atlanta by randomizing eligible couples to receive either CHTC or separate individual voluntary HIV counseling and testing (iVCT). To evaluate the acceptability and safety of CHTC, main outcomes were satisfaction with the intervention and the proportions of couples reporting intimate partner violence (IPV) and relationship dissolution after the service. The results indicated that the service was very acceptable to men (median 7-item index of satisfaction was 34 for CHTC and 35 for iVCT, P = .4). There was no difference in either incident IPV (22% versus 17% for CHTC and iVCT, respectively, P = .6) or relationship dissolution (42% versus 51% for CHTC and iVCT, respectively, P = .5). Based on the preliminary data, CHTC is safe for male couples, and it is equally acceptable to iVCT for men who have main partners. PMID:23995295

  7. 46 CFR 159.007-7 - Application for acceptance for production inspections and tests: Coast Guard action.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Application for acceptance for production inspections and tests: Coast Guard action. 159.007-7 Section 159.007-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS Production Inspection...

  8. 46 CFR 159.007-7 - Application for acceptance for production inspections and tests: Coast Guard action.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Application for acceptance for production inspections and tests: Coast Guard action. 159.007-7 Section 159.007-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS Production Inspection...

  9. 16 CFR § 1616.4 - Sampling and acceptance procedures.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... specimen to one of the three samples. Test each set of three samples and accept or reject each seam design... all the test criteria of § 1616.3(b), accept the seam design. If one or more of the three additional.... Test the sets of three samples and accept or reject the type of trim and design on the same basis as...

  10. Odor Control Test Plan of the Urine Containment Bag (UCB) for Orion Utilization

    NASA Technical Reports Server (NTRS)

    Casper, Stephanie; Williams, Nicole M. M.

    2010-01-01

    The purpose of this test is to evaluate the odor containment of the urine containment bag (UCB), P/N SDD46107234-306 in an environment simulating a spacecraft capsule. The goal is to determine the time of odor break through and the acceptability of the odor, once break through occurs. The goal is to simulate, as close as possible, the volume ratio (trash to free volume), trash content (vomit, urine, feces, and food trash), humidity and temperature of the capsule. The goal for minimum break through is 48 hours (Orion Block 0) from the start of the test. The goal for acceptability of odor is 2 weeks (including docked ISS time for Orion Block 0). Two UCB's will be tested simultaneously in different chambers. The one UCB will be tested empty, serving as a control. Odor break through will be based upon the when the filled UCB total organics exceeds that of the control (empty UCB) by a level detectable by a human panel (approximately 2 ppm).

  11. Test/QA Plan for Verification of Leak Detection and Repair Technologies

    EPA Science Inventory

    The purpose of the leak detection and repair (LDAR) test and quality assurance plan is to specify procedures for a verification test applicable to commercial LDAR technologies. The purpose of the verification test is to evaluate the performance of participating technologies in b...

  12. 46 CFR 170.180 - Plans and information required at the stability test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Displacement and Centers of Gravity § 170.180 Plans and information required at the stability test. The owner.... (c) Capacity plans showing capacities and vertical and longitudinal centers of gravity of stowage...

  13. Possibilities of ground penetrating radar usage within acceptance tests of rigid pavements

    NASA Astrophysics Data System (ADS)

    Stryk, Josef; Matula, Radek; Pospisil, Karel

    2013-10-01

    Within the road pavement acceptance tests, destructive as well as non-destructive tests of individual road layers are performed to verify the standard requirements. The article describes a method for providing quick, effective and sufficiently accurate measurements of both dowel and tie bar positions in concrete pavements, using a two-channel ground penetrating radar (GPR). Measurements were carried out in laboratory and in-situ conditions. A special hand cart for field measurements, set for the testing requirements, was designed. It was verified that following the correct measuring and assessment method, it is possible to reach accuracy of determining the in-built rebar up to 1 cm in vertical direction and up to 1.5 cm per 11.5 m of measured length in horizontal direction. In the in-situ tests, GPR identification of possible anomalies due to the phase of concrete pavement laying was presented. In the conclusion, a measurement report is mentioned. The standard requirements for the position of dowels and tie bars cover maximum possible deviation of the rebar position from the project documentation in vertical and horizontal direction, maximum deflection of rebar ends to each other, and maximum translation of rebar in the direction of its longitudinal axis.

  14. The Unified Language Testing Plan: Speaking Proficiency Test. Spanish and English Pilot Validation Studies. Report Number 1.

    ERIC Educational Resources Information Center

    Thornton, Julie A.

    This report describes one segment of the Federal Language Testing Board's Unified Language Testing Plan (ULTP), the validation of speaking proficiency tests in Spanish and English. The ULTP is a project to increase standardization of foreign language proficiency measurement and promote sharing of resources among testing programs in the federal…

  15. Ordinary risks and accepted fictions: how contrasting and competing priorities work in risk assessment and mental health care planning.

    PubMed

    Coffey, Michael; Cohen, Rachel; Faulkner, Alison; Hannigan, Ben; Simpson, Alan; Barlow, Sally

    2017-06-01

    Communication and information sharing are considered crucial to recovery-focused mental health services. Effective mental health care planning and coordination includes assessment and management of risk and safety. Using data from our cross-national mixed-method study of care planning and coordination, we examined what patients, family members and workers say about risk assessment and management and explored the contents of care plans. Thematic analysis of qualitative research interviews (n = 117) with patients, family members and workers, across four English and two Welsh National Health Service sites. Care plans were reviewed (n = 33) using a structured template. Participants have contrasting priorities in relation to risk. Patients see benefit in discussions about risk, but cast the process as a worker priority that may lead to loss of liberty. Relationships with workers are key to family members and patients; however, worker claims of involving people in the care planning process do not extend to risk assessment and management procedures for fear of causing upset. Workers locate risk as coming from the person rather than social or environmental factors, are risk averse and appear to prioritize the procedural aspects of assessment. Despite limitations, risk assessment is treated as legitimate work by professionals. Risk assessment practice operates as a type of fiction in which poor predictive ability and fear of consequences are accepted in the interests of normative certainty by all parties. As a consequence, risk adverse options are encouraged by workers and patients steered away from opportunities for ordinary risks thereby hindering the mobilization of their strengths and abilities. © 2016 The Authors. Health Expectations Published by John Wiley & Sons Ltd.

  16. First Stage Acceptance Test

    NASA Technical Reports Server (NTRS)

    1960-01-01

    This photograph shows the intense smoke and fire created by the five F-1 engines from a test firing of the Saturn V first stage (S-1C) in the S-1C test stand at the Marshall Space Flight Center. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.

  17. 1st SSME test of 2006

    NASA Image and Video Library

    2006-01-09

    Water vapor surges from the flame deflector of the A-2 Test Stand at NASA's Stennis Space Center on Jan. 9 during the first space shuttle main engine test of the year. The test was an engine acceptance test of flight engine 2058. It's the first space shuttle main engine to be completely assembled at Kennedy Space Center. Objectives also included first-time (green run) tests of a high-pressure oxidizer turbo pump and an Advanced Health System Monitor engine controller. The test ran for the planned duration of 520 seconds.

  18. Maglev program test plan. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    deBenedet, D.; Gilchrist, A.J.; Karanian, L.A.

    1992-07-01

    Maglev systems represent a promising evolution in the high-speed ground transportation, offering speeds in excess of 300 mph along with the potential for low operating costs and minimal environmental impact. The goal of this effort is to investigate the feasibility and viability of maglev systems in the United States. The emergence of a sophisticated technology such as maglev requires a need for a coordinated research test program and the determination of test requirements to identify and mitigate development risk and to maximize the use of domestic resources. The study is directed toward the identification and characterization of maglev systems developmentmore » risks tied to a preliminary system architecture. Research objectives are accomplished by surveying experiences from previous maglev development programs, both foreign and domestic, and interviews with individuals involved with maglev research and testing. Findings include ninety-four distinct development risks and twenty risk types. Planning and implementation requirements are identified for a maglev test program, including the development of a facilities strategy to meet any operational concepts that evolve out of early development effort. Also specified is the logical development flow and associated long-lead support needs for sub-scale and full-scale testing.« less

  19. 46 CFR 170.180 - Plans and information required at the stability test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Displacement and Centers of Gravity § 170.180 Plans and information required at the stability test. The owner...) Capacity plans showing capacities and vertical and longitudinal centers of gravity of stowage spaces and...

  20. 46 CFR 170.180 - Plans and information required at the stability test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Displacement and Centers of Gravity § 170.180 Plans and information required at the stability test. The owner...) Capacity plans showing capacities and vertical and longitudinal centers of gravity of stowage spaces and...

  1. 46 CFR 170.180 - Plans and information required at the stability test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Displacement and Centers of Gravity § 170.180 Plans and information required at the stability test. The owner...) Capacity plans showing capacities and vertical and longitudinal centers of gravity of stowage spaces and...

  2. 46 CFR 170.180 - Plans and information required at the stability test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Displacement and Centers of Gravity § 170.180 Plans and information required at the stability test. The owner...) Capacity plans showing capacities and vertical and longitudinal centers of gravity of stowage spaces and...

  3. Acceptability and feasibility of using established geosocial and sexual networking mobile applications to promote HIV and STD testing among men who have sex with men.

    PubMed

    Sun, Christina J; Stowers, Jason; Miller, Cindy; Bachmann, Laura H; Rhodes, Scott D

    2015-03-01

    This study is the first published multi-app study, of which we are aware, to evaluate both the acceptability and feasibility of providing sexual health information and HIV/STD testing referrals via established geosocial and sexual networking apps for MSM. Data were collected using an online survey and through four apps (A4A Radar, Grindr, Jack'd, and Scruff). Two-thirds (64 %) found apps to be an acceptable source for sexual health information. MSM who found apps as acceptable were more likely non-white, not sure of their current HIV status, and have low HIV testing self-efficacy. One-quarter (26 %) of informational chats with the health educator resulted in users requesting and being referred to local HIV/STD testing sites. There were significant differences in the number and types of interactions across apps. Established apps designed for MSM may be both an acceptable and feasible platform to promote HIV/STD testing. Future research should evaluate interventions that leverage this technology.

  4. Acceptability and feasibility of using established geosocial and sexual networking mobile applications to promote HIV and STD testing among men who have sex with men

    PubMed Central

    Sun, Christina J.; Stowers, Jason; Miller, Cindy; Bachmann, Laura H.; Rhodes, Scott D.

    2014-01-01

    This study is the first published multi-app study, of which we are aware, to evaluate both the acceptability and feasibility of providing sexual health information and HIV/STD testing referrals via established geosocial and sexual networking apps for MSM. Data were collected using an online survey and through four apps (A4A Radar, Grindr, Jack’d, and Scruff). Two-thirds (64%) found apps to be an acceptable source for sexual health information. MSM who found apps as acceptable were more likely non-white men, not sure of their current HIV status, and have low HIV testing self-efficacy. One-quarter (26%) of informational chats with the health educator resulted in users requesting and being referred to local HIV/STD testing sites. There were significant differences in the number and types of interactions across apps. Established apps for MSM may be both an acceptable and feasible platform to promote HIV/STD testing. Future research should evaluate interventions that leverage this technology. PMID:25381563

  5. Guidelines for testing and release procedures

    NASA Technical Reports Server (NTRS)

    Molari, R.; Conway, M.

    1984-01-01

    Guidelines and procedures are recommended for the testing and release of the types of computer software efforts commonly performed at NASA/Ames Research Center. All recommendations are based on the premise that testing and release activities must be specifically selected for the environment, size, and purpose of each individual software project. Guidelines are presented for building a Test Plan and using formal Test Plan and Test Care Inspections on it. Frequent references are made to NASA/Ames Guidelines for Software Inspections. Guidelines are presented for selecting an Overall Test Approach and for each of the four main phases of testing: (1) Unit Testing of Components, (2) Integration Testing of Components, (3) System Integration Testing, and (4) Acceptance Testing. Tools used for testing are listed, including those available from operating systems used at Ames, specialized tools which can be developed, unit test drivers, stub module generators, and the use of format test reporting schemes.

  6. Shuttle payload vibroacoustic test plan evaluation. Free flyer payload applications and sortie payload parametric variations

    NASA Technical Reports Server (NTRS)

    Stahle, C. V.; Gongloff, H. R.

    1977-01-01

    A preliminary assessment of vibroacoustic test plan optimization for free flyer STS payloads is presented and the effects on alternate test plans for Spacelab sortie payloads number of missions are also examined. The component vibration failure probability and the number of components in the housekeeping subassemblies are provided. Decision models are used to evaluate the cost effectiveness of seven alternate test plans using protoflight hardware.

  7. Top Down Implementation Plan for system performance test software

    NASA Technical Reports Server (NTRS)

    Jacobson, G. N.; Spinak, A.

    1982-01-01

    The top down implementation plan used for the development of system performance test software during the Mark IV-A era is described. The plan is based upon the identification of the hierarchical relationship of the individual elements of the software design, the development of a sequence of functionally oriented demonstrable steps, the allocation of subroutines to the specific step where they are first required, and objective status reporting. The results are: determination of milestones, improved managerial visibility, better project control, and a successful software development.

  8. Performance-based quality assurance/quality control (QA/QC) acceptance procedures for in-place soil testing phase 3 : [summary].

    DOT National Transportation Integrated Search

    2015-01-01

    Acceptance of earthwork construction by the Florida Department of Transportation (FDOT) : requires in-place testing conducted with a nuclear density gauge (NDG) to determine : dry density, which must obtain a required percent compaction based upon a ...

  9. System design of the Pioneer Venus spacecraft. Volume 14: Test planning trades

    NASA Technical Reports Server (NTRS)

    Pedretti, C. D.

    1973-01-01

    Pioneer Venus system test plans and trade studies which were first published as Study Tasks (References 1 through 5) are reviewed. The plan and trade studies are presented in a condensed form. Greater detail may be found in the referenced study tasks if desired. All significant conclusions and plan outlines of the original studies are, presented.

  10. 49 CFR Appendix B to Part 180 - Acceptable Internal Self-closing Stop Valve Leakage Tests for Cargo Tanks Transporting Liquefied...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Leakage Tests for Cargo Tanks Transporting Liquefied Compressed Gases B Appendix B to Part 180... Pt. 180, App. B Appendix B to Part 180—Acceptable Internal Self-closing Stop Valve Leakage Tests for.... (b) Internal Self-Closing Stop Valve Test. An operator of a cargo tank that is not equipped with a...

  11. Minnesota urban partnership agreement national evaluation : telecommuting test plan.

    DOT National Transportation Integrated Search

    2009-11-17

    This report presents the telecommuting test plan for the Minnesota Urban Partnership Agreement (UPA) under the United States Department of Transportation (U.S. DOT) UPA Program. The Minnesota UPA projects focus on reducing congestion by employing str...

  12. Identifying and reducing disparities in successful addiction treatment completion: testing the role of Medicaid payment acceptance.

    PubMed

    Guerrero, Erick G; Garner, Bryan R; Cook, Benjamin; Kong, Yinfei; Vega, William A; Gelberg, Lillian

    2017-05-25

    Medicaid has become the largest payer of substance use disorder treatment and may enhance access to quality care and reduce disparities. We tested whether treatment programs' acceptance of Medicaid payments was associated with reduced disparities between Mexican Americans and non-Latino Whites. We analyzed client and program data from 122 publicly funded treatment programs in 2010 and 112 programs in 2013. These data were merged with information regarding 15,412 adult clients from both periods, of whom we selected only Mexican Americans (n = 7130, 46.3%) and non-Latino Whites (n = 8282, 53.7%). We used multilevel logistic regression and variance decomposition to examine associations and underlying factors associated with Mexican American and White differences in treatment completion. Variables of interest included client demographics; drug use severity and mental health issues; and program license, accreditation, and acceptance of Medicaid payments. Mexican Americans had lower odds of treatment completion (OR = 0.677; 95% CI = 0.534, 0.859) compared to non-Latino Whites. This disparity was explained in part by primary drug used, greater drug use severity, history of mental health disorders, and program acceptance of Medicaid payments. The interaction between Mexican Americans and acceptance of Medicaid was statistically significant (OR = 1.284; 95% CI = 1.008, 1.637). Findings highlighted key program and client drivers of this disparity and the promising role of program acceptance of Medicaid payment to eliminate disparities in treatment completion among Mexican Americans. Implications for health policy during the Trump Administration are discussed.

  13. Tests of Halon 1301 test gas simulants

    NASA Astrophysics Data System (ADS)

    Carhart, H. W.; Leonard, J. T.; Dinenno, P. J.; Starchville, M. D.; Forssell, E. W.; Wong, J. T.

    1989-02-01

    All new and retrofit installations of Halon 1301 (CBrF3) total flooding fire protection systems in shipboard machinery spaces require full acceptance discharge test. It is desirable to use a suitable simulant test gas in these tests in view of current and future regulation of Halon 1301. Sulfur hexafluoride, SF6, and chlorodifluromethane R-22, were identified as candidate simulants on the basis of their similarity in physical properties to Halon 1301. These two candidates were then evaluated on the basis of leakage from an enclosure. SF6 was determined to be an excellent simulant for Halon 1301 when considering leakage from an enclosure. Further testing of SF6 and R-22 is planned for other important aspects of Halon 1301 systems, i.e., flow hydraulics, initial mixing.

  14. The Testing of a Desegregation Planning Model in Black and White Neighborhoods in Milwaukee, Wisconsin.

    ERIC Educational Resources Information Center

    Ollie, Bert W., Jr.

    A study was conducted to test a desegregation impact planning model in predominantly black and predominantly white neighborhoods in Milwaukee, Wisconsin. The model tested has seven planning stages, pre-planning through the implementation and revision cycle. The model features feedback loops which permit desegregation planners to get community…

  15. 3. "TEST STAND NO. 13, EXCAVATION PLAN & SECTIONS." Specifications ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. "TEST STAND NO. 1-3, EXCAVATION PLAN & SECTIONS." Specifications No. ENG 04-353-50-10; Drawing No. 60-0906; no sheet number within title block; D.O. SERIES 1109/10. Stamped: AS BUILT. No revisions or revision dates. Last work date on this drawing "Checked by EAG, 1/31/49." Though this drawing is specific to Test Stand 1-3, it also illustrates the general methods used for excavation design and retaining wall construction at Test Stand 1-5. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-3, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  16. 8. "TEST STAND, ARCHITECTURAL, FLOOR PLANS AND SCHEDULES." Specifications No. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. "TEST STAND, ARCHITECTURAL, FLOOR PLANS AND SCHEDULES." Specifications No. ENG-04-353-55-72; Drawing No. 60-0912; sheet 22 of 148; file no. 1320/73. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 4338, no change. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  17. Minnesota urban partnership agreement national evaluation : tolling test plan.

    DOT National Transportation Integrated Search

    2009-11-17

    This report presents the test plan for collecting and analyzing toll data for the Minnesota Urban Partnership Agreement (UPA) under the United States Department of Transportation (U.S. DOT) UPA Program. The Minnesota UPA projects focus on reducing co...

  18. General test plan redundant sensor strapdown IMU evaluation program

    NASA Technical Reports Server (NTRS)

    Hartwell, T.; Irwin, H. A.; Miyatake, Y.; Wedekind, D. E.

    1971-01-01

    The general test plan for a redundant sensor strapdown inertial measuring unit evaluation program is presented. The inertial unit contains six gyros and three orthogonal accelerometers. The software incorporates failure detection and correction logic and a land vehicle navigation program. The principal objective of the test is a demonstration of the practicability, reliability, and performance of the inertial measuring unit with failure detection and correction in operational environments.

  19. ENVIRONMENTAL METHODS TESTING SITE PROJECT: DATA MANAGEMENT PROCEDURES PLAN

    EPA Science Inventory

    The Environmental Methods Testing Site (EMTS) Data Management Procedures Plan identifies the computer hardware and software resources used in the EMTS project. It identifies the major software packages that are available for use by principal investigators for the analysis of data...

  20. Acceptability of testing for anorectal sexually transmitted infections and self-collected anal swabs in female sex workers, men who have sex with men and transgender women in Papua New Guinea.

    PubMed

    Bell, Stephen; Wapling, Johanna; Ase, Sophie; Boli-Neo, Ruthy; Vallely, Andrew J; Kaldor, John M; Nightingale, Claire E; Kelly-Hanku, Angela

    2018-06-20

    Papua New Guinea (PNG) has some of the highest prevalence of urogenital sexually transmitted infections (STIs) in Pacific Asia, but to date, anorectal STI prevalence data do not exist, and diagnosis of anorectal STIs does not occur. The purpose of this study was to document the acceptability of anorectal STI testing and self-collection of anorectal swabs for testing among populations at risk of anorectal STIs, in advance of a large bio-behavioural survey during which this approach to specimen collection was planned among key populations in PNG. Four focus groups were conducted, collecting data from a purposive sample of 35 members of two civil society groups representing female sex workers, men who have sex with men and transgender women in Port Moresby and Goroka. All participants were in favour of anorectal STI testing in PNG. Reasons given for willingness to undertake anorectal STI testing included that anal sex is practised; that anorectal STIs are not perceived to exist; there are self-reported experiences of anorectal symptoms indicative of anorectal STIs; that anorectal STI testing will enhance personal health; and that anorectal STI testing is not currently available in PNG. All participants were confident they could obtain self-collected specimens, although several stated that support from trained health workers should be available for community members who may not feel comfortable with self-collection. This qualitative research is the first study of acceptability of anorectal STI testing and specimen self-collection procedures in PNG, and Pacific Asia more broadly. Our qualitative findings show support for anorectal STI testing including the use of self-collected swabs among key populations in PNG. Study findings informed the inclusion of anorectal STI testing in a large bio-behavioural survey to be used to estimate anorectal STI prevalence among key populations in PNG for the first time.

  1. A Test of Motor (Not Executive) Planning in Developmental Coordination Disorder and Autism

    ERIC Educational Resources Information Center

    van Swieten, Lisa M.; van Bergen, Elsje; Williams, Justin H. G.; Wilson, Andrew D.; Plumb, Mandy S.; Kent, Samuel W.; Mon-Williams, Mark A.

    2010-01-01

    Grip selection tasks have been used to test "planning" in both autism and developmental coordination disorder (DCD). We differentiate between "motor" and "executive" planning and present a modified motor planning task. Participants grasped a cylinder in 1 of 2 orientations before turning it clockwise or anticlockwise.…

  2. In situ gas treatment technology demonstration test plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thornton, E.C.; Miller, R.D.

    1996-02-16

    This document defines the objectives and requirements associated with undertaking a field demonstration of an in situ gas treatment appoach to remediation chromate-contaminated soil. The major tasks presented in this plan include the design and development of the surface gas treatment system, performance of permitting activities, and completion of site preparation and field testing activities.

  3. Predicting the Operational Acceptability of Route Advisories

    NASA Technical Reports Server (NTRS)

    Evans, Antony; Lee, Paul

    2017-01-01

    NASA envisions a future Air Traffic Management system that allows safe, efficient growth in global operations, enabled by increasing levels of automation and autonomy. In a safety-critical system, the introduction of increasing automation and autonomy has to be done in stages, making human-system integrated concepts critical in the foreseeable future. One example where this is relevant is for tools that generate more efficient flight routings or reroute advisories. If these routes are not operationally acceptable, they will be rejected by human operators, and the associated benefits will not be realized. Operational acceptance is therefore required to enable the increased efficiency and reduced workload benefits associated with these tools. In this paper, the authors develop a predictor of operational acceptability for reroute advisories. Such a capability has applications in tools that identify more efficient routings around weather and congestion and that better meet airline preferences. The capability is based on applying data mining techniques to flight plan amendment data reported by the Federal Aviation Administration and data on requested reroutes collected from a field trial of the NASA developed Dynamic Weather Routes tool, which advised efficient route changes to American Airlines dispatchers in 2014. 10-Fold cross validation was used for feature, model and parameter selection, while nested cross validation was used to validate the model. The model performed well in predicting controller acceptance or rejection of a route change as indicated by chosen performance metrics. Features identified as relevant to controller acceptance included the historical usage of the advised route, the location of the maneuver start point relative to the boundaries of the airspace sector containing the maneuver start (the maneuver start sector), the reroute deviation from the original flight plan, and the demand level in the maneuver start sector. A random forest with forty

  4. [Acceptance and rejection of vasectomy in rural males].

    PubMed

    García Moreno, Juan; Solano Sainos, Luis Miguel

    2005-01-01

    One problem in rural population is the gap between coverage of contraception and scant masculine participation, which could be due to lack of information of to other sociocultural factors. We investigated, in two stages, the characteristics or the profile of the sexual and reproductive behavior of males in an exploratory study by means of focus groups to determine their relevant motivations and characteristics and subsequently, a structured questionnaire to ascertain the magnitude of the factors explored. The population corresponded to zones of rural hospital medical services zones of medical services in seven ethnic groups of the Mexican Republic and included men who accepted and who rejected vasectomy. The profile of males who accepted vasectomy allowed to determine that there exist a unsatisfied demand for contraceptive protection and the desire of not having additional children; in addition, we found that the decision to accept vasectomy is determined to a greater extent for reasons different from that of information on the contraceptive method. The important proportion of males who were non-users of contraceptive methods who accepted vasectomy supposed information on contraception to be the most consistent reason; nonetheless, this information was not considered sufficient and timely; thus, adverse economic situation, a certain condition related with the couple such as health or love for the female partner are the more weighty reasons for deciding to accept vasectomy, while the fear of poor sexual performance is the most powerful factor for rejection of vasectomy. Masculine participation in family planning is a factor that conditions contraceptive coverage and its respective benefits. The profile of the male who accepts vasectomy aids in identifying candidates forthe procedure and in reducing unsatisfied demand. Greater diffusion of information of the contraceptive method of vasectomy, greater links between male needs and vasectomy, and maintaining or

  5. The Relationship between Treatment Acceptability and Familism

    ERIC Educational Resources Information Center

    Pemberton, Joy R.; Borrego, Joaquin, Jr.

    2005-01-01

    Many studies have examined the acceptability of treatments for children with disruptive behaviors. However, few studies to date have tested the effects of home environment variables such as family support on treatment acceptability. In the current study, parents' level of familism was used to predict their willingness to accept several behavioral…

  6. 49 CFR Appendix B to Part 180 - Acceptable Internal Self-closing Stop Valve Leakage Tests for Cargo Tanks Transporting Liquefied...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Acceptable Internal Self-closing Stop Valve Leakage Tests for Cargo Tanks Transporting Liquefied Compressed Gases B Appendix B to Part 180... Leakage Tests for Cargo Tanks Transporting Liquefied Compressed Gases For internal self-closing stop valve...

  7. Computer-aided dispatch--traffic management center field operational test final detailed test plan : WSDOT deployment

    DOT National Transportation Integrated Search

    2003-10-01

    The purpose of this document is to expand upon the evaluation components presented in "Computer-aided dispatch--traffic management center field operational test final evaluation plan : WSDOT deployment". This document defines the objective, approach,...

  8. Factors determining acceptance of voluntary HIV counseling and testing among pregnant women attending antenatal clinic at army hospitals in Addis Ababa.

    PubMed

    Worku, Getachew; Enquselassie, Fikre

    2007-01-01

    Mother-to-child transmission (MTCT) is by far the largest spurce of HIV infection in children below the age of 15 years. For many years little was known about preventing transmission of HIV infection from mother to child. Recently however, many interventions are available to reduce mother to child transmission, such as anti retroviral drug and avoidance of breastfeeding. For women to take advantage of measures to reduce transmission, they need to know their HIV status. The objective of the study was to identify factors determining acceptance of voluntary HIV testing among pregnant women at army hospitals in Addis Ababa. A case control study was conducted in 88 acceptors and 176 non-acceptors of VCT using structured pre tested questionnaire from December 2004 to January 2005, at army hospitals in Addis Ababa. Among socio-demographic factors the odds of VCT acceptance was higher among better educated, married, with higher income women and among women whose husbands live at the same house. Women who had better knowledge of VCT and MTCT and women with frequent ANC visit had significantly higher VCT acceptance than their counterparts. Adjusted for socio-demographic and some reproductive characteristics VCT acceptance was significantly associated with knowledge about MTCT (OR = 7.34, 95% CI = 3.44, 15.67), previous VCT experience (OR = 2.51, 95% CI = 1.03, 6.17) and husbands residence (at the same house) (OR= 4.97, 95% CI = 2.15, 11.46). Education of the mother, knowledge of MTCT and VCT and partner participation were important factors of VCT acceptance. The study gives useful information to health care providers to introduce measures that could improve the utilization of antenatal HIV testing.

  9. MSFC Doppler Lidar Science experiments and operations plans for 1981 airborne test flight

    NASA Technical Reports Server (NTRS)

    Fichtl, G. H.; Bilbro, J. W.; Kaufman, J. W.

    1981-01-01

    The flight experiment and operations plans for the Doppler Lidar System (DLS) are provided. Application of DLS to the study of severe storms and local weather penomena is addressed. Test plans involve 66 hours of flight time. Plans also include ground based severe storm and local weather data acquisition.

  10. 33 CFR 155.1065 - Procedures for plan submission, approval, requests for acceptance of alternative planning...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... complete English language copy of a vessel response plan to Commandant (CG-5431), Coast Guard, 2100 2nd St... a period of up to 5 years from the date of approval. (d) If the Coast Guard reviews the plan and...., SW., Stop 7581, Washington, DC 20593-7581. [CGD 91-034, 61 FR 1081, Jan. 12, 1996, as amended by CGD...

  11. Measuring Acceptance of Sleep Difficulties: The Development of the Sleep Problem Acceptance Questionnaire.

    PubMed

    Bothelius, Kristoffer; Jernelöv, Susanna; Fredrikson, Mats; McCracken, Lance M; Kaldo, Viktor

    2015-11-01

    Acceptance may be an important therapeutic process in sleep medicine, but valid psychometric instruments measuring acceptance related to sleep difficulties are lacking. The purpose of this study was to develop a measure of acceptance in insomnia, and to examine its factor structure as well as construct validity. In a cross-sectional design, a principal component analysis for item reduction was conducted on a first sample (A) and a confirmatory factor analysis on a second sample (B). Construct validity was tested on a combined sample (C). Questionnaire items were derived from a measure of acceptance in chronic pain, and data were gathered through screening or available from pretreatment assessments in four insomnia treatment trials, administered online, via bibliotherapy and in primary care. Adults with insomnia: 372 in sample A and 215 in sample B. Sample C (n = 820) included sample A and B with another 233 participants added. Construct validity was assessed through relations with established acceptance and sleep scales. The principal component analysis presented a two-factor solution with eight items, explaining 65.9% of the total variance. The confirmatory factor analysis supported the solution. Acceptance of sleep problems was more closely related to subjective symptoms and consequences of insomnia than to diary description of sleep, or to acceptance of general private events. The Sleep Problem Acceptance Questionnaire (SPAQ), containing the subscales "Activity Engagement" and "Willingness", is a valid tool to assess acceptance of insomnia. © 2015 Associated Professional Sleep Societies, LLC.

  12. An Overview of the NASA Aeronautics Test Program Strategic Plan

    NASA Technical Reports Server (NTRS)

    Marshall, Timothy J.

    2010-01-01

    U.S. leadership in aeronautics depends on ready access to technologically advanced, efficient, and affordable aeronautics test capabilities. These systems include major wind tunnels and propulsion test facilities and flight test capabilities. The federal government owns the majority of the major aeronautics test capabilities in the United States, primarily through the National Aeronautics and Space Administration (NASA) and the Department of Defense (DoD), however an overarching strategy for management of these national assets was needed. Therefore, in Fiscal Year (FY) 2006 NASA established the Aeronautics Test Program (ATP) as a two-pronged strategic initiative to: (1) retain and invest in NASA aeronautics test capabilities considered strategically important to the agency and the nation, and (2) establish a strong, high level partnership with the DoD Test Resources Management Center (TRMC), stewards of the DoD test and evaluation infrastructure. Since then, approximately seventy percent of the ATP budget has been directed to underpin fixed and variable costs of facility operations within its portfolio and the balance towards strategic investments in its test facilities, including maintenance and capability upgrades. Also, a strong guiding coalition was established through the National Partnership for Aeronautics Testing (NPAT), with governance by the senior leadership of NASA s Aeronautics Research Mission Directorate (ARMD) and the DoD's TRMC. As part of its strategic planning, ATP has performed or participated in many studies and analyses, including assessments of major NASA and DoD aeronautics test capabilities, test facility condition evaluations and market research. The ATP strategy has also benefitted from unpublished RAND research and analysis by Ant n et al. (2009). Together, these various studies, reports and assessments serve as a foundation for a new, five year strategic plan that will guide ATP through FY 2014. Our vision for the future is a balanced

  13. The Acceptance Strategy for Nuclear Power Plant In Indonesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suhaemi, Tjipta; Syaukat, Achmad

    2010-06-22

    Indonesia has planned to build nuclear power plants. Some feasibility studies have been conducted intensively. However, the processes of NPP introduction are still uncertain. National Energy Plan in Indonesia, which has been made by some governmental agencies, does not yet give positive impact to the government decision to construct the nuclear power plant (NPP). This paper discusses the process of NPP introduction in Indonesia, which has been colored with debate of stakeholder and has delayed decision for go-nuclear. The technology paradigm is used to promote NPP as an alternative of reliable energy resources. This paradigm should be complemented with internationalmore » politic-economic point of view. The international politic-economic point of view shows that structural powers, consisting of security, production, finance, and knowledge structures, within which the NPP is introduced, have dynamic characteristics. The process of NPP introduction in Indonesia contains some infrastructure development (R and D, legislation, regulation, energy planning, site study, public acceptance efforts, etc), but they need a better coherent NPP implementation program and NPP Acceptance Program. Strategic patterns for NPP acceptance described in this paper are made by considering nuclear regulation development and the interest of basic domestic participation. The first NPP program in Indonesia having proven technology and basic domestic participation is and important milestone toward and optimal national energy-mix.« less

  14. 9. "TEST STAND; STRUCTURAL; CABLE TUNNEL, PLAN, SECTIONS, DETAILS." Specifications ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. "TEST STAND; STRUCTURAL; CABLE TUNNEL, PLAN, SECTIONS, DETAILS." Specifications No. OC1-55-72-(Rev.); Drawing No. 60-09-12; sheet 43 of 148; file no. AF 1320/94, Rev. A. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 4338, no change. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  15. Computer-aided dispatch--traffic management center field operational test final test plans : state of Utah

    DOT National Transportation Integrated Search

    2004-01-01

    The purpose of this document is to expand upon the evaluation components presented in "Computer-aided dispatch--traffic management center field operational test final evaluation plan : state of Utah". This document defines the objective, approach, an...

  16. Multi-EMR Structured Data Entry Form: User-Acceptance Testing of a Prototype.

    PubMed

    Zavar, Abbas; Keshavjee, Karim

    2017-01-01

    Capturing standardized data from multiple EMRs at the point of care is highly desirable for a variety of uses, including quality improvement programs, multi-centered clinical trials and clinical decision support. In this paper, we describe the design, development and user acceptance testing of a prototype web-based form (the Form) that can integrate with multiple EMRs. We used the validated UTAUT questionnaire to assess the likelihood of uptake of the Form into clinical practice. The Form was found to be easy to use, elicits low anxiety, supports productivity and is perceived to have good support. Users would benefit from training and from better social signaling about the importance of using the Form in their practice. Making the Form more fun and interesting could help increase uptake.

  17. TEST REACTOR AREA PLOT PLAN CA. 1968. MTR AND ETR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    TEST REACTOR AREA PLOT PLAN CA. 1968. MTR AND ETR AREAS SOUTH OF PERCH AVENUE. "COLD" SERVICES NORTH OF PERCH. ADVANCED TEST REACTOR IN NEW SECTION WEST OF COLD SERVICES SECTION. NEW PERIMETER FENCE ENCLOSES BETA RAY SPECTROMETER, TRA-669, AN ATR SUPPORT FACILITY, AND ATR STACK. UTM LOCATORS HAVE BEEN DELETED. IDAHO NUCLEAR CORPORATION, FROM A BLAW-KNOX DRAWING, 3/1968. INL INDEX NO. 530-0100-00-400-011646, REV. 0. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  18. Performance deterioration due to acceptance testing and flight loads; JT90 jet engine diagnostic program

    NASA Technical Reports Server (NTRS)

    Olsson, W. J.

    1982-01-01

    The results of a flight loads test of the JT9D-7 engine are presented. The goals of this test program were to: measure aerodynamic and inertia loads on the engine during flight, explore the effects of airplane gross weight and typical maneuvers on these flight loads, simultaneously measure the changes in engine running clearances and performance resulting from the maneuvers, make refinements of engine performance deterioration prediction models based on analytical results of the tests, and make recommendations to improve propulsion system performance retention. The test program included a typical production airplane acceptance test plus additional flights and maneuvers to encompass the range of flight loads in revenue service. The test results indicated that aerodynamic loads, primarily at take-off, were the major cause of rub-indicated that aerodynamic loads, primarily at take-off, were the major cause of rub-induced deterioration in the cold sectin of the engine. Differential thermal expansion between rotating and static parts plus aerodynamic loads combined to cause blade-to-seal rubs in the turbine.

  19. Independent Evaluation of the Driver Acceptance of the Cooperative Intersection Collision Avoidance System for Violations (CICAS-V) Pilot Test

    DOT National Transportation Integrated Search

    2011-07-01

    This report documents the results of the independent evaluations assessment of the driver acceptance of the Cooperative Intersection Collision Avoidance System limited to Stop Sign and Traffic Signal Violations (CICAS-V) system as tested during a ...

  20. Non Destructive Test Dye Penetrant and Ultrasonic on Welding SMAW Butt Joint with Acceptance Criteria ASME Standard

    NASA Astrophysics Data System (ADS)

    Endramawan, T.; Sifa, A.

    2018-02-01

    The purpose of this research is to know the type of discontinuity of SMAW welding result and to determine acceptance criteria based on American Society of Mechanical Engineer (ASME) standard. Material used is mild steel 98,71% Fe and 0,212% C with hardness 230 VHN with specimen diameter 20 cm and thickness 1.2 cm which is welded use SMAW butt joint with electrode for rooting LB 52U diameter 2.6 mm, current 70 Ampere and voltage 380 volt, filler used LB 5218 electrode diameter 3.2 mm with current 80 Ampere and 380 volt. The method used to analyze the welded with non destructive test dye penetrant (PT) method to see indication on the surface of the object and Ultrasonic (UT) to see indication on the sub and inner the surface of the object, the result is discontinuity recorded and analyzed and then the discontinuity is determine acceptance criteria based on the American Society of Mechanical Engineer (ASME) standards. The result show the discontinuity of porosity on the surface of the welded and inclusion on sub material used ultrasonic test, all indication on dye penetrant or ultrasonic test if there were rejected of result of welded that there must be gouging on part which rejected and then re-welding.

  1. Aboveground Injection Sytem Construction and Mecahnical Integrity Test Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Jun

    An In-Situ Bioremediation (ISB) Pilot Test Treatability Study is planned at Sandia National Laboratories, New Mexico (SNL/NM) Technical Area-V (TA-V) Groundwater Area of Concern. The Treatability Study is designed to gravity inject an electron-donor substrate and bioaugmentation bacteria into groundwater using an injection well. The constituents of concern (COCs) are nitrate and trichloroethene (TCE). The Pilot Test Treatability Study will evaluate the effectiveness of bioremediation and COC treatment over a prescribed period of time. Results of the pilot test will provide data that will be used to evaluate the cost and effectiveness of a fullscale system.

  2. Top-Mounted Propulsion Test Plans (TMP17)

    NASA Technical Reports Server (NTRS)

    Bridges, James; Henderson, Brenda; Huff, Dennis

    2017-01-01

    NASA recently completed a study of propulsion cycles and nozzle types applicable to a 70-passenger, M1.6 supersonic airliner, paying especial attention to the noise produced during landing and take-off. The results of the study were validated in a model-scale test at NASA Glenn last summer. The findings of that study and test, along with other studies, have resulted in a new strategy for achieving the Commercial Supersonic Technologys goals for noise and performance. Key to that strategy is moving the propulsion to the top-side of the vehicle and modifying the nozzle and inlet to maximally shield the propulsion noise while maintaining efficient operation. Installed exhaust configurations have been designed to minimize the exhaust noise using new acoustic design tools. A test planned for the fall of 2017 will validate both the new design tools and the low-noise concept using a new translating phased array. During the test, questions regarding modifications of convected waves in the jet near-field that are key to new understandings of aft jet noise will be addressed. Also, to better tie rig results to real-world measurements, a model-scale version of a nozzle that was flight tested by Glenn Research Center in 2001 will be tested.

  3. A Collaborative Web-Based Approach to Planning Research, Integration, and Testing Using a Wiki

    NASA Technical Reports Server (NTRS)

    Delaney, Michael M.; Koshimoto, Edwin T.; Noble, Deleena; Duggan, Christopher

    2010-01-01

    The National Aeronautics and Space Administration Integrated Vehicle Health Management program touches on many different research areas while striving to enable the automated detection, diagnosis, prognosis, and mitigation of adverse events at the aircraft and system level. At the system level, the research focus is on the evaluation of multidisciplinary integrated methods, tools, and technologies for achieving the program goal. The participating program members form a diverse group of government, industry, and academic researchers. The program team developed the Research and Test Integration Plan in order to track significant test and evaluation activities, which are important for understanding, demonstrating, and communicating the overall project state and project direction. The Plan is a living document, which allows the project team the flexibility to construct conceptual test scenarios and to track project resources. The Plan also incorporates several desirable feature requirements for Plan users and maintainers. A wiki has proven to be the most efficient and effective means of implementing the feature requirements for the Plan. The wiki has proven very valuable as a research project management tool, and there are plans to expand its scope.

  4. [Willingness on accepting the short-message-service and factors related to HIV/STD testing among male STD clinic clients].

    PubMed

    Meng, Xiaojun; Zou, Huachun; Jia, Tianjian; Zhu, Chen; Chen, Xin; Zhang, Xuan

    2015-12-01

    To understand the willingness on acceptance of a short-messageservice (SMS) program provided for HIV/STD testing and the related factors, among male clients at the STD clinics in China. Convenience sampling method was used to select study subjects at a STD clinic in Wuxi, Jiangsu province. A questionnaire survey was conducted among the subjects to collect the information on socio-demographic characteristics and willingness of acceptance to the SMS. A total of 368 SMS subjects were surveyed, in which 75.5% expressed the willingness of acceptance, while 57.2% and 38.1% of them wanted to receive the short message every 3 months or 6 months, respectively. 53.8% of the respondents showed their willingness to share the news with their sexual partners about SMS and 44.8% of them would do the same to their friends. Data from the Multivariate logistic regression analysis showed that those who had received senior high school or above education (aOR=3.632, 95%CI: 1.939-6.715) , having homosexual behavior (aOR = 1.973, 95%CI: 1.234-8.358) or those having received AIDS related intervention service in the past year (aOR=9.416, 95%CI: 4.822-18.309) were more likely to accept the SMS. SMS seemed to be acceptable among the male STD clinic clients in Wuxi, suggesting that it is feasible to conduct the SMS as a strategy to improve the HIV/STDs testing program at the STD clinics in the future. Promotion of SMS should be strengthened and the provision of general AIDS intervention service at the STD clinics should be established in order to make more STD clinic clients understand this SMS.

  5. Process test plan, phase II: waste retrieval sluicing system emissions collection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    POWERS, R.L.

    1999-06-01

    This Process Test Plan is prepared to continue from HNF-3733 which was Phase I of the test. Supplemental operational controls and sampling requirements are defined to safely obtain gas samples from the 296-C-006 ventilation system stack during active operation of the sluicing equipment.

  6. 26. "TEST STAND, STRUCTURAL, FOUNDATION PLAN." Specifications No. ENG043535572; Drawing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    26. "TEST STAND, STRUCTURAL, FOUNDATION PLAN." Specifications No. ENG-04-353-55-72; Drawing No. 60-0912; sheet 25 of 148; file no. 1320/76. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 4338, no change. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  7. The Careful Puppet Master: Reducing risk and fortifying acceptance testing with Jenkins CI

    NASA Astrophysics Data System (ADS)

    Smith, Jason A.; Richman, Gabriel; DeStefano, John; Pryor, James; Rao, Tejas; Strecker-Kellogg, William; Wong, Tony

    2015-12-01

    Centralized configuration management, including the use of automation tools such as Puppet, can greatly increase provisioning speed and efficiency when configuring new systems or making changes to existing systems, reduce duplication of work, and improve automated processes. However, centralized management also brings with it a level of inherent risk: a single change in just one file can quickly be pushed out to thousands of computers and, if that change is not properly and thoroughly tested and contains an error, could result in catastrophic damage to many services, potentially bringing an entire computer facility offline. Change management procedures can—and should—be formalized in order to prevent such accidents. However, like the configuration management process itself, if such procedures are not automated, they can be difficult to enforce strictly. Therefore, to reduce the risk of merging potentially harmful changes into our production Puppet environment, we have created an automated testing system, which includes the Jenkins CI tool, to manage our Puppet testing process. This system includes the proposed changes and runs Puppet on a pool of dozens of RedHat Enterprise Virtualization (RHEV) virtual machines (VMs) that replicate most of our important production services for the purpose of testing. This paper describes our automated test system and how it hooks into our production approval process for automatic acceptance testing. All pending changes that have been pushed to production must pass this validation process before they can be approved and merged into production.

  8. 14 CFR 431.45 - Mishap investigation plan and emergency response plan.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... shall also submit an emergency response plan (ERP) that contains procedures for informing the affected public of a planned RLV mission. An acceptable ERP satisfies the requirements of paragraph (e) of this section. The MIP and ERP shall be signed by an individual authorized to sign and certify the application...

  9. Evaluation and Acceptability of a Simplified Test of Visual Function at Birth in a Limited-Resource Setting.

    PubMed

    Carrara, Verena I; Darakomon, Mue Chae; Thin, Nant War War; Paw, Naw Ta Kaw; Wah, Naw; Wah, Hser Gay; Helen, Naw; Keereecharoen, Suporn; Paw, Naw Ta Mlar; Jittamala, Podjanee; Nosten, François H; Ricci, Daniela; McGready, Rose

    2016-01-01

    Neurological examination, including visual fixation and tracking of a target, is routinely performed in the Shoklo Malaria Research Unit postnatal care units on the Thailand-Myanmar border. We aimed to evaluate a simple visual newborn test developed in Italy and performed by non-specialized personnel working in neonatal care units. An intensive training of local health staff in Thailand was conducted prior to performing assessments at 24, 48 and 72 hours of life in healthy, low-risk term singletons. The 48 and 72 hours results were then compared to values obtained to those from Italy. Parents and staff administering the test reported on acceptability. One hundred and seventy nine newborns, between June 2011 and October 2012, participated in the study. The test was rapidly completed if the infant remained in an optimal behavioral stage (7 ± 2 minutes) but the test duration increased significantly (12 ± 4 minutes, p < 0.001) if its behavior changed. Infants were able to fix a target and to discriminate a colored face at 24 hours of life. Horizontal tracking of a target was achieved by 96% (152/159) of the infants at 48 hours. Circular tracking, stripe discrimination and attention to distance significantly improved between each 24-hour test period. The test was easily performed by non-specialized local staff and well accepted by the parents. Healthy term singletons in this limited-resource setting have a visual response similar to that obtained to gestational age matched newborns in Italy. It is possible to use these results as a reference set of values for the visual assessment in Karen and Burmese infants in the first 72 hours of life. The utility of the 24 hours test should be pursued.

  10. Detailed technical plan for Test Program Element-III (TPE-III) of the first wall/blanket shield engineering test program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turner, L.R.; Praeg, W.F.

    1982-03-01

    The experimental requirements, test-bed design, and computational requirements are reviewed and updated. Next, in Sections 3, 4 and 5, the experimental plan, instrumentation, and computer plan, respectively, are described. Finally, Section 6 treats other considerations, such as personnel, outside participation, and distribution of results.

  11. 40 CFR 35.917-6 - Acceptance by implementing governmental units.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works-Clean Water Act § 35.917-6 Acceptance by implementing governmental units. A facilities plan submitted for...

  12. 40 CFR 35.917-6 - Acceptance by implementing governmental units.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works-Clean Water Act § 35.917-6 Acceptance by implementing governmental units. A facilities plan submitted for...

  13. 40 CFR 35.917-6 - Acceptance by implementing governmental units.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works-Clean Water Act § 35.917-6 Acceptance by implementing governmental units. A facilities plan submitted for...

  14. 40 CFR 35.917-6 - Acceptance by implementing governmental units.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works-Clean Water Act § 35.917-6 Acceptance by implementing governmental units. A facilities plan submitted for...

  15. Low Temperature Power Coating (LTPC) Phase 2 Laboratory Test Plan and Procedures for PACAF (Rev D)

    DTIC Science & Technology

    2018-03-20

    Δa*, LTPC Phase II Laboratory Test Plan and Procedures Rev D (CDRL A004) BATTELLE | 20 March 2018 | 6 Δb* and ΔE will be calculated post ...BATTELLE | CONTRACT NUMBER: FA8532-17-C-0008 (CDRL A004) LTPC Phase II Laboratory Test Plan and Procedures (Rev D) Prepared by... Test Plan and Procedures Rev D (CDRL A004) BATTELLE | 20 March 2018 | i List of Acronyms AGE Aircraft Ground Equipment ASTM American

  16. 4. "TEST STAND NO. 13, CONCRETE STRUCTURAL PLAN AND ELEVATION." ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. "TEST STAND NO. 1-3, CONCRETE STRUCTURAL PLAN AND ELEVATION." Specifications No. OC11-50-10; Drawing No. 60-09-06; no sheet number within title block. D.O. SERIES 1109/12 REV. E. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract DA-04-353 Eng. 177, Rev. E; Date: 17 Dec. 1951. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-3, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  17. Minnesota urban partnership agreement national evaluation : content analysis test plan.

    DOT National Transportation Integrated Search

    2009-11-17

    This report presents the content analysis test plan for the Minnesota Urban Partnership Agreement (UPA) under the United States Department of Transportation (U.S. DOT) UPA Program. The Minnesota UPA projects focus on reducing congestion by employing ...

  18. Peace, Equanimity, and Acceptance in the Cancer Experience (PEACE): Validation of a scale to assess acceptance and struggle with terminal illness

    PubMed Central

    Mack, Jennifer W.; Nilsson, Matthew; Balboni, Tracy; Friedlander, Robert J.; Block, Susan D.; Trice, Elizabeth; Prigerson, Holly G.

    2013-01-01

    Objectives The role of emotional acceptance of a terminal illness in end-of-life (EOL) care is not known. We developed a measure of peaceful acceptance at the EOL, and evaluated the role of peaceful acceptance in EOL decision-making and care. Methods We developed the Peace, Equanimity, and Acceptance in the Cancer Experience (PEACE) questionnaire to measure the extent to which patients with advanced cancer feel a sense of peaceful acceptance of their terminal illness. The scale was administered to 160 advanced cancer patients along with measures of other attributes hypothesized to be related to acceptance, including cognitive acceptance of terminal illness. EOL outcomes in 56 patients who died during the study were also examined. Results The 12-item PEACE questionnaire had two subscales: a 7-item Struggle with Illness (Cronbach's α =.81) and a 5-item Peaceful Acceptance (α = .78) subscale. Both subscales were associated with patients’ self-reported peacefulness (r=.66 for acceptance, P<.0001; r=−.37 for struggle, P<.0001.) Struggle with Illness scores were associated with cognitive terminal illness acknowledgement (mean scores 14.9 versus 12.4, P=.001) and some aspects of advance care planning (living will or health care proxy, mean scores 13.9 versus 11.5, P=.02). In addition, among patients who had died, use of a feeding tube at the EOL was inversely associated with Peaceful Acceptance (P=.015). Conclusion The PEACE questionnaire is a valid and reliable measure of Peaceful Acceptance and Struggle with Illness. Scores are associated with some choices for EOL care among patients with advanced cancer. PMID:18429006

  19. "Students want HIV testing in schools" a formative evaluation of the acceptability of HIV testing and counselling at schools in Gauteng and North West provinces in South Africa.

    PubMed

    Madiba, Sphiwe; Mokgatle, Mathilda

    2015-04-17

    The proposal by the South African Health Ministry to implement HIV testing and counselling (HTC) at schools in 2011 generated debates about the appropriateness of such testing. However, the debate has been between the Ministries of Education and Health, with little considerations of the students. The main aim of the study was to assess the students' opinions and uptake of HIV testing and counselling in general, and the acceptability of the provision of HIV testing and counselling in schools. The study also determined the association between socio-demographic characteristics, sexual behaviour, and HIV testing behaviour of the students. A survey was conducted among grade 10-12 high school students in North West and Gauteng provinces, South Africa. Seventeen high schools (nine rural and eight urban) were randomly selected for the administration of a researcher-assisted, self-administered, semi-structured questionnaire. A total of 2970 students aged 14-27 years participated in the study; 1632 (55%) were girls, 1810 (61%) ever had sex, and 1271 (49.8%) had more than one sex partner. The mean age of first sexual activity was 15.6. Half (n = 1494, 50.1%) had been tested for HIV. Having multiple sexual partners, age, and gender were significantly associated with increased odds of having had a HIV test. Fear, being un-informed about HTC, and low HIV risk perceptions were the reasons for not getting tested. The acceptability of HTC at school was high (n = 2282, 76.9%) and 2129 (71.8%) were willing to be tested at school. Appropriateness, privacy, and secrecy were the main arguments for and against HTC at school. One-third (n = 860, 29%) had intentions to disclose their HIV status to students versus 1258 (42.5%) for teachers. Stigma, discrimination and secrecy were the primary reasons students did not intend to disclose. A high acceptability of HTC and willingness to be tested at school suggest that HIV prevention programs tailored to youth have a high potential of success

  20. The development of an automated flight test management system for flight test planning and monitoring

    NASA Technical Reports Server (NTRS)

    Hewett, Marle D.; Tartt, David M.; Duke, Eugene L.; Antoniewicz, Robert F.; Brumbaugh, Randal W.

    1988-01-01

    The development of an automated flight test management system (ATMS) as a component of a rapid-prototyping flight research facility for AI-based flight systems concepts is described. The rapid-prototyping facility includes real-time high-fidelity simulators, numeric and symbolic processors, and high-performance research aircraft modified to accept commands for a ground-based remotely augmented vehicle facility. The flight system configuration of the ATMS includes three computers: the TI explorer LX and two GOULD SEL 32/27s.

  1. A theory-based decision aid for patients with cancer: results of feasibility and acceptability testing of DecisionKEYS for cancer.

    PubMed

    Hollen, Patricia J; Gralla, Richard J; Jones, Randy A; Thomas, Christopher Y; Brenin, David R; Weiss, Geoffrey R; Schroen, Anneke T; Petroni, Gina R

    2013-03-01

    Appropriate utilization of treatment is a goal for all patients undergoing cancer treatment. Proper treatment maximizes benefit and limits exposure to unnecessary measures. This report describes findings of the feasibility and acceptability of implementing a short, clinic-based decision aid and presents an in-depth clinical profile of the participants. This descriptive study used a prospective, quantitative approach to obtain the feasibility and acceptability of a decision aid (DecisionKEYS for Balancing Choices) for use in clinical settings. It combined results of trials of patients with three different common malignancies. All groups used the same decision aid series. Participants included 80 patients with solid tumors (22 with newly diagnosed breast cancer, 19 with advanced prostate cancer, and 39 with advanced lung cancer) and their 80 supporters as well as their physicians and nurses, for a total of 160 participants and 10 health professionals. The decision aid was highly acceptable to patient and supporter participants in all diagnostic groups. It was feasible for use in clinic settings; the overall value was rated highly. Of six physicians, all found the interactive format with the help of the nurse as feasible and acceptable. Nurses also rated the decision aid favorably. This intervention provides the opportunity to enhance decision making about cancer treatment and warrants further study including larger and more diverse groups. Strengths of the study included a theoretical grounding, feasibility testing of a practical clinic-based intervention, and summative evaluation of acceptability of the intervention by patient and supporter pairs. Further research also is needed to test the effectiveness of the decision aid in diverse clinical settings and to determine if this intervention can decrease overall costs.

  2. Flight Test Hazard Planning Near the Speed of Light

    NASA Technical Reports Server (NTRS)

    Henwood, Bart; Huete, Rod

    2007-01-01

    A viewgraph presentation describing flight test safety near the speed of light is shown. The topics include: 1) Concept; 2) Portal Content; 3) Activity to Date; 4) FTS Database Updatd FAA Program; 5) FAA Flight Test Risk Management; 6) CFR 14 Part 21.35 Current and proposed changes; 7) An Online Resource for Flight Test Safety Planning; 8) Data Gathering; 9) NTPS Role; 10) Example Maturation; 11) Many Varied Inputs; 12) Matured Stall Hazards; 13) Loss of Control Mitigations; 14) FAA Access; 15) NASA PBMA Website Link; 16) FAR Reference Search; 17) Record Field Search; 18) Keyword Search; and 19) Results of FAR Reference Search.

  3. Minnesota urban partnership agreement national evaluation : safety data test plan.

    DOT National Transportation Integrated Search

    2009-11-17

    This report provides the safety data test plan for the Minnesota Urban Partnership Agreement (UPA) under the United States Department of Transportation (U.S. DOT) UPA Program. The Minnesota UPA projects focus on reducing congestion by employing strat...

  4. Minnesota urban partnership agreement national evaluation : exogenous factors test plan.

    DOT National Transportation Integrated Search

    2009-11-17

    This report presents the exogenous factors test plan for the national evaluation of the Minnesota Urban Partnership Agreement (UPA) under the United States Department of Transportation (U.S. DOT) UPA Program. The Minnesota UPA projects focus on reduc...

  5. Family planning and social position of women.

    PubMed

    Begum, Hasna

    1993-04-01

    This presentation began with at least three biases: (i) Acceptance of a secular approach to the problem of artificially controlling human reproduction; (ii) acceptance of an absolute egalitarian position in matter of choices and applications of family planning methods; and (iii) acceptance of the view that a small family gives women more opportunities to flourish as humans. The conclusion of the presentation is: though in implementing family planning programmes much deviation from the egalitarian principle could be found, in reality the implementation itself does bring about some opportunities for women to enhance their position in society. Undoubtedly the malpractices in family planning programmes cause death and miseries to women. But, until better methods are invented for both male and female sexes to replace the harmful ones and the male members of the society feel equal responsibility in matters of controlling reproduction, women have now no other choice but to accept the lesser evil.

  6. Testing the validity and acceptability of the diagnostic criteria for Hoarding Disorder: a DSM-5 survey.

    PubMed

    Mataix-Cols, D; Fernández de la Cruz, L; Nakao, T; Pertusa, A

    2011-12-01

    The DSM-5 Obsessive-Compulsive Spectrum Sub-Workgroup is recommending the creation of a new diagnostic category named Hoarding Disorder (HD). The validity and acceptability of the proposed diagnostic criteria have yet to be formally tested. Obsessive-compulsive disorder/hoarding experts and random members of the American Psychiatric Association (APA) were shown eight brief clinical vignettes (four cases meeting criteria for HD, three with hoarding behaviour secondary to other mental disorders, and one with subclinical hoarding behaviour) and asked to decide the most appropriate diagnosis in each case. Participants were also asked about the perceived acceptability of the criteria and whether they supported the inclusion of HD in the main manual. Altogether, 211 experts and 48 APA members completed the survey (30% and 10% response rates, respectively). The sensitivity and specificity of the HD diagnosis and the individual criteria were high (80-90%) across various types of professionals, irrespective of their experience with hoarding cases. About 90% of participants in both samples thought the criteria would be very/somewhat acceptable for professionals and sufferers. Most experts (70%) supported the inclusion of HD in the main manual, whereas only 50% of the APA members did. The proposed criteria for HD have high sensitivity and specificity. The criteria are also deemed acceptable for professionals and sufferers alike. Training of professionals and the development and validation of semi-structured diagnostic instruments should improve diagnostic accuracy even further. A field trial is now needed to confirm these encouraging findings with real patients in real clinical settings.

  7. SU-F-T-180: Evaluation of a Scintillating Screen Detector for Proton Beam QA and Acceptance Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghebremedhin, A; Taber, M; Koss, P

    2016-06-15

    Purpose: To test the performance of a commercial scintillating screen detector for acceptance testing and Quality Assurance of a proton pencil beam scanning system. Method: The detector (Lexitek DRD 400) has 40cm × 40cm field, uses a thin scintillator imaged onto a 16-bit scientific CCD with ∼0.5mm resolution. A grid target and LED illuminators are provided for spatial calibration and relative gain correction. The detector mounts to the nozzle with micron precision. Tools are provided for image processing and analysis of single or multiple Gaussian spots. Results: The bias and gain of the detector were studied to measure repeatability andmore » accuracy. Gain measurements were taken with the LED illuminators to measure repeatability and variation of the lens-CCD pair as a function with f-stop. Overall system gain was measured with a passive scattering (broad) beam whose shape is calibrated with EDR film placed in front of the scintillator. To create a large uniform field, overlapping small fields were recorded with the detector translated laterally and stitched together to cover the full field. Due to the long exposures required to obtain multiple spills of the synchrotron and very high detector sensitivity, borated polyethylene shielding was added to reduce direct radiation events hitting the CCD. Measurements with a micro ion chamber were compared to the detector’s spot profile. Software was developed to process arrays of Gaussian spots and to correct for radiation events. Conclusion: The detector background has a fixed bias, a small component linear in time, and is easily corrected. The gain correction method was validated with 2% accuracy. The detector spot profile matches the micro ion chamber data over 4 orders of magnitude. The multiple spot analyses can be easily used with plan data for measuring pencil beam uniformity and for regular QA comparison.« less

  8. Langley Research Center's Unitary Plan Wind Tunnel: Testing Capabilities and Recent Modernization Activities

    NASA Technical Reports Server (NTRS)

    Micol, John R.

    2001-01-01

    Description, capabilities, initiatives, and utilization of the NASA Langley Research Center's Unitary Plan Wind Tunnel are presented. A brief overview of the facility's operational capabilities and testing techniques is provided. A recent Construction of Facilities (CoF) project to improve facility productivity and efficiency through facility automation has been completed and is discussed. Several new and maturing thrusts are underway that include systematic efforts to provide credible assessment for data quality, modifications to the new automation control system for increased compatibility with the Modern Design Of Experiments (MDOE) testing methodology, and process improvements for better test coordination, planning, and execution.

  9. Langley Research Center's Unitary Plan Wind Tunnel: Testing Capabilities and Recent Modernization Activities

    NASA Technical Reports Server (NTRS)

    Micol, John R.

    2001-01-01

    Description, capabilities, initiatives, and utilization of the NASA Langley Research Center's Unitary Plan Wind Tunnel are presented. A brief overview of the facility's operational capabilities and testing techniques is provided. A recent Construction of Facilities (Car) project to improve facility productivity and efficiency through facility automation has been completed and is discussed. Several new and maturing thrusts are underway that include systematic efforts to provide credible assessment for data quality, modifications to the new automation control system for increased compatibility with the Modern Design of Experiments (MDOE) testing methodology, and process improvements for better test coordination, planning, and execution.

  10. A Randomized Controlled Trial of Acceptance-Based Behavior Therapy and Cognitive Therapy for Test Anxiety: A Pilot Study

    ERIC Educational Resources Information Center

    Brown, Lily A.; Forman, Evan M.; Herbert, James D.; Hoffman, Kimberly L.; Yuen, Erica K.; Goetter, Elizabeth M.

    2011-01-01

    Many university students suffer from test anxiety that is severe enough to impair performance. Given mixed efficacy results of previous cognitive-behavior therapy (CBT) trials and a theoretically driven rationale, an acceptance-based behavior therapy (ABBT) approach was compared to traditional CBT (i.e., Beckian cognitive therapy; CT) for the…

  11. Integrated corridor management analysis, modeling, and simulation experimental plan for the test corridor.

    DOT National Transportation Integrated Search

    2008-03-01

    This document, the AMS Experimental Plan, lays out the scope of analysis that will be conducted through the application of the AMS methodology to the Test Corridor. The specific objectives of the Experimental Plan are: create an AMS framework that id...

  12. Selected topics in railroad tank car safety. Volume 2 : test plan for accelerated life testing of thermally shielded tank cars

    DOT National Transportation Integrated Search

    1978-08-01

    A test plan for the accelerated life testing of thermally shielded tank cars is described. The test program would be conducted at the DOT Transportation Test Center in Pueblo, Colorado. Eighteen tank cars would be included in the program. Five cars w...

  13. 40 CFR Appendix Xv to Part 86 - Procedure for Determining an Acceptable Exhaust Regeneration Durability-Data Test Schedule for...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Procedure for Determining an Acceptable Exhaust Regeneration Durability-Data Test Schedule for Diesel Cycle Vehicles Equipped With... Schedule for Diesel Cycle Vehicles Equipped With Periodically Regenerating Trap Oxidizer Systems Certifying...

  14. Consumer detection and acceptability of reduced-sodium bread.

    PubMed

    La Croix, Kimberly W; Fiala, Steven C; Colonna, Ann E; Durham, Catherine A; Morrissey, Michael T; Drum, Danna K; Kohn, Melvin A

    2015-06-01

    Bread is the largest contributor of Na to the American diet and excess Na consumption contributes to premature death and disability. We sought to determine the Na level at which consumers could detect a difference between reduced-Na bread and bread with typical Na content, and to determine if consumer sensory acceptability and purchase intent differed between reduced-Na bread and bread with typical Na content. Difference testing measured ability to detect differences in control bread and reduced-Na bread using two-alternative forced choice testing. Acceptability was measured using a nine-point hedonic scale and purchase intent was measured using a five-point purchase intent scale. Difference and acceptability testing were conducted in Portland, OR, USA in January 2013. Eighty-two consumers participated in difference testing and 109 consumers participated in acceptability testing. Consumers did not detect a difference in saltiness between the control bread and the 10 % reduced-Na bread, but did detect a difference between the control bread and bread reduced in Na content by 20 % and 30 %. Na reductions had no effect on consumer acceptability of sensory characteristics, including overall liking, appearance, aroma, flavour, sweetness, salt level and texture, or purchase intent. Reducing Na levels by up to 30 % in the sandwich bread tested did not affect consumer liking or purchase intent of the product. These results support national recommendations for small, incremental Na reductions in the food supply over time and assure bread manufacturers that sensory characteristics and consumer purchase intent of their products will be preserved after Na reductions occur.

  15. International Space Station Environmental Control and Life Support System Acceptance Testing for Node 1 Temperature and Humidity Control Subsystem

    NASA Technical Reports Server (NTRS)

    Williams, David E.

    2011-01-01

    The International Space Station (ISS) Node 1 Environmental Control and Life Support (ECLS) System is comprised of five subsystems: Atmosphere Control and Storage (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). This paper will provide a summary of the Node 1 ECLS THC subsystem design and a detailed discussion of the ISS ECLS Acceptance Testing methodology utilized for this subsystem.The International Space Station (ISS) Node 1 Environmental Control and Life Support (ECLS) System is comprised of five subsystems: Atmosphere Control and Storage (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). This paper will provide a summary of the Node 1 ECLS THC subsystem design and a detailed discussion of the ISS ECLS Acceptance Testing methodology utilized for this subsystem.

  16. Underground Test Area Quality Assurance Project Plan Nevada National Security Site, Nevada, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Irene Farnham

    This Quality Assurance Project Plan (QAPP) provides the overall quality assurance (QA) program requirements and general quality practices to be applied to the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) Underground Test Area (UGTA) Sub-Project (hereafter the Sub-Project) activities. The requirements in this QAPP are consistent with DOE Order 414.1C, Quality Assurance (DOE, 2005); U.S. Environmental Protection Agency (EPA) Guidance for Quality Assurance Project Plans for Modeling (EPA, 2002); and EPA Guidance on the Development, Evaluation, and Application of Environmental Models (EPA, 2009). The QAPP Revision 0 supersedes DOE--341, Underground Test Area Quality Assurancemore » Project Plan, Nevada Test Site, Nevada, Revision 4.« less

  17. Vaginal contraceptive film gains wider acceptance.

    PubMed

    1992-09-01

    In US health departments and family planning clinics, women are beginning to accept vaginal contraceptive film more widely. Further, direct sales of this method, which is also distributed over the counter, has increased. In fact, in 1991, vaginal contraceptive film was the top selling contraceptive in pharmacies. This 2.5 sq. inch water-soluble film is impregnated with nonoxynol-9. The woman uses her finger to insert the folded square as close as possible to the cervix 5-60 minutes before intercourse. If the time between acts of intercourse is greater than 1 hour, she must insert another square. After it dissolves, it is a firm gel removed by vaginal and cervical fluids. The company realizes that its relatively high cost (about $3.59 for 3 films) prevents some family planning providers from offering the film. It has tried to cut costs by not using extra packaging material and by manufacturing it in the US instead of ain England. A manager of the family planning clinic at R.E. Thomason County Hospital in El Paso, Texas, notes that user compliance is higher with the vaginal contraceptive film than foam. In fact, patients at the Planned Parenthood League of Middlesex County, New Jersey, favor the film because it is less messy than foam. Teenagers in El Paso prefer the film because of the privacy issue and gives them more control to protect themselves from pregnancy. A worker at the New Jersey clinic recommends the film as a backup method for women beginning to use oral contraceptives. She also suggests to patients requesting condoms to also use the film. The company makes the same recommendation. Yet, family planning workers note that some women cannot convince partners to use the condom. 90% of patients at the El Paso clinic are Hispanic, and they tend to not accept condom use. Some providers suggest using 2 applications of the film to defend against sexually transmitted diseases, but there is no evidence that double application actually does so.

  18. HIV coping self-efficacy: a key to understanding stigma and HIV test acceptance among incarcerated men in Jamaica.

    PubMed

    Andrinopoulos, Katherine; Kerrigan, Deanna; Figueroa, J Peter; Reese, Richard; Ellen, Jonathan M

    2010-03-01

    Although prisons have been noted as important venues for HIV testing, few studies have explored the factors within this context that may influence HIV test acceptance. Moreover, there is a dearth of research related to HIV and incarcerated populations in middle and low-income countries, where both the burden of HIV and the number of people incarcerated is higher compared to high-income countries. This study explores the relationship between HIV coping self-efficacy, HIV-related stigma, and HIV test acceptance in the largest prisons in Jamaica. A random sample of inmates (n=298) recruited from an HIV testing demonstration project were asked to complete a cross-sectional quantitative survey. Participants who reported high HIV coping self-efficacy (adjusted odds ratio (AOR) 1.86: 95% confidence interval CI 1.24-2.78, p-value=0.003), some perceived risk of HIV (AOR 2.51: 95% (CI) 1.57-4.01, p-value=0.000), and low HIV testing stigma (AOR 1.71: 95% CI 1.05-2.79, p-value=0.032) were more likely to test for HIV. Correlates of HIV coping self-efficacy included external and internal HIV stigma (AOR 1.28: 95% CI 1.25-1.32, p-value=0.000 and AOR 1.76: 95% CI 1.34-2.30, p-value=0.000, respectively), social support (AOR 2.09: 95% CI 1.19-3.68, p-value=0.010), and HIV knowledge (AOR 2.33: 95% CI 1.04-5.22, p-value=0.040). Policy and programs should focus on the interrelationships of these constructs to increase participation in HIV testing in prison.

  19. LPT. Shield test facility (TAN645 and 646). Floor plan and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Shield test facility (TAN-645 and -646). Floor plan and room names. Ralph M. Parsons 1229-17 ANP/GE-6-645-A-1. April 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 037-0645/0646-00-693-107347 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  20. Model Checking Artificial Intelligence Based Planners: Even the Best Laid Plans Must Be Verified

    NASA Technical Reports Server (NTRS)

    Smith, Margaret H.; Holzmann, Gerard J.; Cucullu, Gordon C., III; Smith, Benjamin D.

    2005-01-01

    Automated planning systems (APS) are gaining acceptance for use on NASA missions as evidenced by APS flown On missions such as Orbiter and Deep Space 1 both of which were commanded by onboard planning systems. The planning system takes high level goals and expands them onboard into a detailed of action fiat the spacecraft executes. The system must be verified to ensure that the automatically generated plans achieve the goals as expected and do not generate actions that would harm the spacecraft or mission. These systems are typically tested using empirical methods. Formal methods, such as model checking, offer exhaustive or measurable test coverage which leads to much greater confidence in correctness. This paper describes a formal method based on the SPIN model checker. This method guarantees that possible plans meet certain desirable properties. We express the input model in Promela, the language of SPIN and express the properties of desirable plans formally.

  1. Reliability and validity of Kano Test for Social Nicotine Dependence (KTSND), and development of its revised scale assessing the psychosocial acceptability of smoking among university students.

    PubMed

    Kitada, Masako; Musashi, Manabu; Kano, Masato

    2011-08-01

    To examine reliability and validity of Kano Test for Social Nicotine Dependence (KTSND), a scale assessing the psychosocial acceptability of smoking, and to develop a new version when validity or reliability of KTSND was not acceptable. We carried out a self-administered cross-sectional survey on undergraduate university students. The participants completed the KTSND, and supplemented three questions on the attitudes toward tobacco control policies and smoking states. Using daily smokers, we examined the relationship between the KTSND and Fagerström Test for Nicotine Dependence (FTND). In each study, we examined test-retest reliability and construct validity, discriminant and convergent validity, and factor validity. Although the KTSND had high internal consistency (Cronbach's a 0.82) and high test-retest reliability (r=0.72), the results of factor analysis were unacceptable; we expected three factors to be extracted, however, only two factors of "Overestimate of smoking usefulness" and "Allege smoking as a taste and/or culture" were extracted. Using the Kano's Test for Assessing Acceptability of Smoking (KTAAS), the new version of KTSND in which a question was replaced with another one, the third factor of "Neglect of harm of tobacco smoking" was extracted adding to the above-mentioned two. KTAAS had also both high internal consistency (Cronbach's alpha 0.82) and test-retest reliability (r=0.66). Overall, the KTSND and the KTAAS score differed according to smoking states, and the nonsmokers' scores were the lowest. The KTSND was a popular questionnaire in Japan, however, its validity assessed using factor analysis was not acceptable, while KTAAS had sufficient reliability and validity, and might assess the cognition and attitude affirming or accepting tobacco smoking among university students.

  2. Draft Plan to Develop Non-Intrusive Load Monitoring Test Protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mayhorn, Ebony T.; Sullivan, Greg P.; Petersen, Joseph M.

    2015-09-29

    This document presents a Draft Plan proposed to develop a common test protocol that can be used to evaluate the performance requirements of Non-Intrusive Load Monitoring. Development on the test protocol will be focused on providing a consistent method that can be used to quantify and compare the performance characteristics of NILM products. Elements of the protocols include specifications for appliances to be used, metrics, instrumentation, and a procedure to simulate appliance behavior during tests. In addition, three priority use cases for NILM will be identified and their performance requirements will specified.

  3. Randomized comparison of two Internet-supported fertility-awareness-based methods of family planning.

    PubMed

    Fehring, Richard J; Schneider, Mary; Raviele, Kathleen; Rodriguez, Dana; Pruszynski, Jessica

    2013-07-01

    The aim was to compare the efficacy and acceptability of two Internet-supported fertility-awareness-based methods of family planning. Six hundred and sixty-seven women and their male partners were randomized into either an electronic hormonal fertility monitor (EHFM) group or a cervical mucus monitoring (CMM) group. Both groups utilized a Web site with instructions, charts and support. Acceptability was assessed online at 1, 3 and 6 months. Pregnancy rates were determined by survival analysis. The EHFM participants (N=197) had a total pregnancy rate of 7 per 100 users over 12 months of use compared with 18.5 for the CMM group (N=164). The log rank survival test showed a significant difference (p<.01) in survival functions. Mean acceptability for both groups increased significantly over time (p<.0001). Continuation rates at 12 months were 40.6% for the monitor group and 36.6% for the mucus group. In comparison with the CMM, the EHFM method of family planning was more effective. All users had an increase in acceptability over time. Results are tempered by the high dropout rate. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. 78 FR 57450 - State Rail Plan Guidance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-18

    ... development of State rail plans, as appropriate. A commenter recommended that the FRA Regional Manager be... integration of State rail plan development within the statewide/nonmetropolitan transportation planning... Guidance is to describe the processes for the development, submission, and acceptance of State rail plans...

  5. Acceptance and commissioning of a treatment planning system based on Monte Carlo calculations.

    PubMed

    Lopez-Tarjuelo, J; Garcia-Molla, R; Juan-Senabre, X J; Quiros-Higueras, J D; Santos-Serra, A; de Marco-Blancas, N; Calzada-Feliu, S

    2014-04-01

    The Monaco Treatment Planning System (TPS), based on a virtual energy fluence model of the photon beam head components of the linac and a dose computation engine made with Monte Carlo (MC) algorithm X-Ray Voxel MC (XVMC), has been tested before being put into clinical use. An Elekta Synergy with 6 MV was characterized using routine equipment. After the machine's model was installed, a set of functionality, geometric, dosimetric and data transfer tests were performed. The dosimetric tests included dose calculations in water, heterogeneous phantoms and Intensity Modulated Radiation Therapy (IMRT) verifications. Data transfer tests were run for every imaging device, TPS and the electronic medical record linked to Monaco. Functionality and geometric tests were run properly. Dose calculations in water were in accordance with measurements so that, in 95% of cases, differences were up to 1.9%. Dose calculation in heterogeneous media showed expected results found in the literature. IMRT verification results with an ionization chamber led to dose differences lower than 2.5% for points inside a standard gradient. When an 2-D array was used, all the fields passed the g (3%, 3 mm) test with a percentage of succeeding points between 90% and 95%, of which the majority of the mentioned fields had a percentage of succeeding points between 95% and 100%. Data transfer caused problems that had to be solved by means of changing our workflow. In general, tests led to satisfactory results. Monaco performance complied with published international recommendations and scored highly in the dosimetric ambit. However, the problems detected when the TPS was put to work together with our current equipment showed that this kind of product must be completely commissioned, without neglecting data workflow, before treating the first patient.

  6. Test/QA Plan (TQAP) for Verification of Semi-Continuous Ambient Air Monitoring Systems

    EPA Science Inventory

    The purpose of the semi-continuous ambient air monitoring technology (or MARGA) test and quality assurance plan is to specify procedures for a verification test applicable to commercial semi-continuous ambient air monitoring technologies. The purpose of the verification test is ...

  7. Definition study for an extended manned test of a regenerative life support system, preliminary test plan

    NASA Technical Reports Server (NTRS)

    1971-01-01

    A preliminary plan and procedure are presented for conducting an extended manned test program for a regenerative life support system. Emphasis will be placed on elements associated with long-term system operation and long-term uninterrupted crew confinement.

  8. Benefits of Using Planned Comparisons Rather Than Post Hoc Tests: A Brief Review with Examples.

    ERIC Educational Resources Information Center

    DuRapau, Theresa M.

    The rationale behind analysis of variance (including analysis of covariance and multiple analyses of variance and covariance) methods is reviewed, and unplanned and planned methods of evaluating differences between means are briefly described. Two advantages of using planned or a priori tests over unplanned or post hoc tests are presented. In…

  9. An acceptance-oriented cognitive-behavioral therapy in multimodal rehabilitation: a pre-post test evaluation in highly distressed patients with rheumatic diseases.

    PubMed

    Vriezekolk, Johanna E; Eijsbouts, Agnes M M; van Lankveld, Wim G J M; Beenackers, Hanneke; Geenen, Rinie; van den Ende, Cornelia H M

    2013-06-01

    To examine the potential effectiveness of a multimodal rehabilitation program including an acceptance-oriented cognitive-behavioral therapy for highly distressed patients with rheumatic diseases. An observational study employing a one-group pre-post test design (N=25). The primary outcome was psychological distress. Secondary outcomes were quality of life, illness acceptance, and coping flexibility. Group pre-to-post and pre-to-12 months follow-up treatment changes were evaluated by paired-samples t-tests and Cohen's effect sizes (d). Individual changes were evaluated by the reliable change index (RCI) and clinically significant change (CSC) parameters. Significant effects were found post-treatment and maintained at 12 months in psychological distress (d>0.80), illness acceptance (d=1.48) and the SF-36 subscales role physical, vitality, and mental health (d ≥ 0.65). No significant effects were found for coping flexibility and the SF-36 subscales physical functioning, bodily pain, social functioning, and role emotional. Both a reliable (RCI) and clinically significant (CSC) improvement was observed for almost half of the highly distressed patients. The patients enrolled in the multimodal rehabilitation program showed improved psychological health status from pre to post-treatment. A randomized clinical trial is needed to confirm or refute the added value of an acceptance-oriented cognitive-behavioral therapy for highly distressed patients in rehabilitation. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  10. Shifting away from doorstep distribution of contraceptives in urban Bangladesh: effects on discontinuation and acceptance of family planning.

    PubMed

    Routh, S; Jahan, S A

    2000-01-01

    This paper examined the effects of alternative service-delivery strategies with regard to dropouts among the current pill and condom users who, before the intervention, were supplied with the methods by the fieldworkers at their homes in an operations research conducted by the Centre for Health and Population Research in urban Bangladesh. Moreover, the effects of the selective home visitation approach on acceptance of modern family planning methods among current nonusers were assessed. Two program areas of the Concerned Women for Family Planning in Dhaka City, one each at Wari and Siddiquebazar, served as the comparison areas. Data for the analyses came from the service records of the fieldworkers and community-based surveys. Results showed that the contraceptive prevalence rate (CPR) considerably increased in both the intervention areas: from the pre-intervention level of 63% to 68% at the Hazaribag primary health care clinic (PHCC) intervention area and from 55% to 57% at the Gandaria community service points (CSPs) intervention area. The corresponding increases at the two comparison areas were from 61% to 63% at Wari and from 60% to 63% at Siddiquebazar. The quantitative growth in the CPR in the PHCC-based strategy clearly indicated the comparative advantage of the clinic-based strategy in terms of sustainable program performance over conventional doorstep CBD- and CSP-based strategies.

  11. Trimodal interpretation of constraints for planning

    NASA Technical Reports Server (NTRS)

    Krieger, David; Brown, Richard

    1987-01-01

    Constraints are used in the CAMPS knowledge based planning system to represent those propositions that must be true for a plan to be acceptable. CAMPS introduces the make-mode for interpreting a constraint. Given an unsatisfied constraint, make evaluation mode suggests planning actions which, if taken, would result in a modified plan in which the constraint in question may be satisfied. These suggested planning actions, termed delta-tuples, are the raw material of intelligent plan repair. They are used both in debugging an almost-right plan and in replanning due to changing situations. Given a defective plan in which some set of constraints are violated, a problem solving strategy selects one or more constraints as a focus of attention. These selected constraints are evaluated in the make-mode to produce delta-tuples. The problem solving strategy then reviews the delta-tuples according to its application and problem-specific criteria to find the most acceptable change in terms of success likelihood and plan disruption. Finally, the problem solving strategy makes the suggested alteration to the plan and then rechecks constraints to find any unexpected consequences.

  12. Nevada Test Site Resource Management Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-12-01

    The Nevada Test Site (NTS) Resource Management Plan (RMP) describes the NTS Stewardship Mission and how its accomplishment will preserve the resources of the ecoregion while accomplishing the objectives of the mission. The NTS Stewardship Mission is to manage the land and facilities at the NTS as a unique and valuable national resource. The RMP has defined goals for twelve resource areas based on the principles of ecosystem management. These goals were established using an interdisciplinary team of DOE/NV resource specialists with input from surrounding land managers, private parties, and representatives of Native American governments. The overall goal of themore » RMP is to facilitate improved NTS land use management decisions within the Great Basin and Mojave Desert ecoregions.« less

  13. PREPARE: guidelines for planning animal research and testing

    PubMed Central

    Smith, Adrian J; Clutton, R Eddie; Lilley, Elliot; Hansen, Kristine E Aa; Brattelid, Trond

    2017-01-01

    There is widespread concern about the quality, reproducibility and translatability of studies involving research animals. Although there are a number of reporting guidelines available, there is very little overarching guidance on how to plan animal experiments, despite the fact that this is the logical place to start ensuring quality. In this paper we present the PREPARE guidelines: Planning Research and Experimental Procedures on Animals: Recommendations for Excellence. PREPARE covers the three broad areas which determine the quality of the preparation for animal studies: formulation, dialogue between scientists and the animal facility, and quality control of the various components in the study. Some topics overlap and the PREPARE checklist should be adapted to suit specific needs, for example in field research. Advice on use of the checklist is available on the Norecopa website, with links to guidelines for animal research and testing, at https://norecopa.no/PREPARE. PMID:28771074

  14. PREPARE: guidelines for planning animal research and testing.

    PubMed

    Smith, Adrian J; Clutton, R Eddie; Lilley, Elliot; Hansen, Kristine E Aa; Brattelid, Trond

    2018-04-01

    There is widespread concern about the quality, reproducibility and translatability of studies involving research animals. Although there are a number of reporting guidelines available, there is very little overarching guidance on how to plan animal experiments, despite the fact that this is the logical place to start ensuring quality. In this paper we present the PREPARE guidelines: Planning Research and Experimental Procedures on Animals: Recommendations for Excellence. PREPARE covers the three broad areas which determine the quality of the preparation for animal studies: formulation, dialogue between scientists and the animal facility, and quality control of the various components in the study. Some topics overlap and the PREPARE checklist should be adapted to suit specific needs, for example in field research. Advice on use of the checklist is available on the Norecopa website, with links to guidelines for animal research and testing, at https://norecopa.no/PREPARE .

  15. Joint ETV/NOWATECH test plan for the Sorbisense GSW40 passive sampler

    EPA Science Inventory

    The joint test plan is the implementation of a test design developed for verification of the performance of an environmental technology following the NOWATECH ETV method. The verification is a joint verification with the US EPA ETV scheme and the Advanced Monitoring Systems Cent...

  16. Kilowatt Isotope Power System: component test report for the Ground Demonstration System Alternator Stator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brainard, E.L.

    1978-04-25

    Results are presented of acceptance tests conducted on the Alternator Stator, S/N 002, for the Kilowatt Isotope Power System. These results show that the Alternator Stator, S/N 002 for the Kilowatt Isotope Power System has satisfactorily completed the testing set forth within Sundstrand Test Specification 2538. Test requirements of TS 2538 were extracted from the Kilowatt Isotope Power System, and Phase I Test Plan.

  17. Aerosol can puncture device operational test plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leist, K.J.

    1994-05-03

    Puncturing of aerosol cans is performed in the Waste Receiving and Processing Facility Module 1 (WRAP 1) process as a requirement of the waste disposal acceptance criteria for both transuranic (TRU) waste and low-level waste (LLW). These cans have contained such things as paints, lubricating oils, paint removers, insecticides, and cleaning supplies which were used in radioactive facilities. Due to Westinghouse Hanford Company (WHC) Fire Protection concerns of the baseline system`s fire/explosion proof characteristics, a study was undertaken to compare the baseline system`s design to commercially available puncturing devices. While the study found no areas which might indicate a riskmore » of fire or explosion, WHC Fire Protection determined that the puncturing system must have a demonstrated record of safe operation. This could be obtained either by testing the baseline design by an independent laboratory, or by substituting a commercially available device. As a result of these efforts, the commercially available Aerosolv can puncturing device was chosen to replace the baseline design. Two concerns were raised with the system. Premature blinding of the coalescing/carbon filter, due to its proximity to the puncture and draining operation; and overpressurization of the collection bottle due to its small volume and by blinding of the filter assembly. As a result of these concerns, testing was deemed necessary. The objective of this report is to outline test procedures for the Aerosolv.« less

  18. The manufacturing, assembly and acceptance testing of the breadboard cryogenic Optical Delay Line for DARWIN

    NASA Astrophysics Data System (ADS)

    van den Dool, T. C.; Kamphues, F.; Gielesen, W.; Dorrepaal, M.; Doelman, N.; Loix, N.; Verschueren, J. P.; Kooijman, P. P.; Visser, M.; Velsink, G.; Fleury, K.

    2005-08-01

    TNO, in cooperation with Micromega-Dynamics, SRON, Dutch Space and CSL, has developed a compact breadboard cryogenic Optical Delay Line for use in future space interferometry missions. The work is performed under ESA contract in preparation for the DARWIN mission. The breadboard delay line is representative of a future flight mechanism, with all used materials and processes being flight representative. The delay line has a single stage voice coil actuator for Optical Path Difference (OPD) control, driving a two-mirror cat's eye. Magnetic bearings are used for guiding. They provide frictionless and wear free operation with zero-hysteresis. The manufacturing, assembly and acceptance testing have been completed and are reported in this paper. The verification program, including functional testing at 40 K, will start in the final quarter of 2005.

  19. 40 CFR 600.007-08 - Vehicle acceptability.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Vehicle acceptability. 600.007-08... FUEL ECONOMY AND CARBON-RELATED EXHAUST EMISSIONS OF MOTOR VEHICLES Fuel Economy and Carbon-Related... Vehicle acceptability. (a) All certification vehicles and other vehicles tested to meet the requirements...

  20. 40 CFR 600.007-80 - Vehicle acceptability.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Vehicle acceptability. 600.007-80... FUEL ECONOMY AND CARBON-RELATED EXHAUST EMISSIONS OF MOTOR VEHICLES Fuel Economy and Carbon-Related... Vehicle acceptability. (a) All certification vehicles and other vehicles tested to meet the requirements...

  1. Aesthetic acceptance equals to nature's compensation plus surgical correction.

    PubMed

    Vadgaonkar, Vaishali; Gangurde, Parag; Karandikar, Anita; Mahajan, Nikhil

    2013-07-25

    Orthognathic surgery has become an acceptable treatment plan for patients with various maxillofacial deformities. The rehabilitation of severe class III adult patients requires a complex interdisciplinary orthodontic and orthognathic approach. This presentation aims to show a case of combination of camouflage and bilateral sagittal split osteotomy (BSSO).Camouflage in maxillary arch was accepted after analysing visual treatment objective (VTO) and pleasing soft tissue compensation which gave us the clue to go ahead for surgical correction of excess mandibular length to achieve best aesthetic outcome while maintaining nature's compensation in upper arch.

  2. Acceptance- versus Change-Based Pain Management: The Role of Psychological Acceptance

    ERIC Educational Resources Information Center

    Blacker, Kara J.; Herbert, James D.; Forman, Evan M.; Kounios, John

    2012-01-01

    This study compared two theoretically opposed strategies for acute pain management: an acceptance-based and a change-based approach. These two strategies were compared in a within-subjects design using the cold pressor test as an acute pain induction method. Participants completed a baseline pain tolerance assessment followed by one of the two…

  3. Acceptance model of a Hospital Information System.

    PubMed

    Handayani, P W; Hidayanto, A N; Pinem, A A; Hapsari, I C; Sandhyaduhita, P I; Budi, I

    2017-03-01

    The purpose of this study is to develop a model of Hospital Information System (HIS) user acceptance focusing on human, technological, and organizational characteristics for supporting government eHealth programs. This model was then tested to see which hospital type in Indonesia would benefit from the model to resolve problems related to HIS user acceptance. This study used qualitative and quantitative approaches with case studies at four privately owned hospitals and three government-owned hospitals, which are general hospitals in Indonesia. The respondents involved in this study are low-level and mid-level hospital management officers, doctors, nurses, and administrative staff who work at medical record, inpatient, outpatient, emergency, pharmacy, and information technology units. Data was processed using Structural Equation Modeling (SEM) and AMOS 21.0. The study concludes that non-technological factors, such as human characteristics (i.e. compatibility, information security expectancy, and self-efficacy), and organizational characteristics (i.e. management support, facilitating conditions, and user involvement) which have level of significance of p<0.05, significantly influenced users' opinions of both the ease of use and the benefits of the HIS. This study found that different factors may affect the acceptance of each user in each type of hospital regarding the use of HIS. Finally, this model is best suited for government-owned hospitals. Based on the results of this study, hospital management and IT developers should have more understanding on the non-technological factors to better plan for HIS implementation. Support from management is critical to the sustainability of HIS implementation to ensure HIS is easy to use and provides benefits to the users as well as hospitals. Finally, this study could assist hospital management and IT developers, as well as researchers, to understand the obstacles faced by hospitals in implementing HIS. Copyright © 2016

  4. Genetic testing for the risk of developing late effects among survivors of childhood cancer: Consumer understanding, acceptance, and willingness to pay.

    PubMed

    Georgiou, Gabrielle; Wakefield, Claire E; McGill, Brittany C; Fardell, Joanna E; Signorelli, Christina; Hanlon, Lucy; Tucker, Kathy; Patenaude, Andrea F; Cohn, Richard J

    2016-09-15

    Genetic testing to determine cancer survivors' risk of developing late effects from their cancer treatment will be increasingly used in survivorship care. This 2-stage study with 64 survivors of childhood cancer and their parents investigated the preferences and acceptability of testing among those who may be at risk of developing late effects. The first stage (Stage 1) identified the most commonly perceived benefits and concerns regarding genetic testing for the risk of late effects among 24 participants. In Stage 2, during interviews, 20 survivors (55% of whom were female; mean age, 26.0 years [range, 18-39 years]; standard deviation [SD], 0.80) and 20 parents (55% of whom were male; mean age of child survivor, 14.2 years [range, 10-19 years]; SD, 0.79) rated the 7 most common benefits and concerns from those identified in Stage 1. Interviews were transcribed verbatim and analyzed. Decisional balance ratios were calculated by dividing the participants' average concerns scores with the average benefits scores. Genetic testing for late effects was highly acceptable: 95% of participants leaned toward testing, and the majority (65.9%) would pay up to Australian $5000. The majority (97.2%) reported it was acceptable to wait for up to 6 months to receive results, and to be offered testing immediately after treatment or when the survivor reached adulthood (62.9%). Survivors and parents had a highly positive decisional balance (Mean (M), 0.5 [SD, 0.38] and M, 0.5 [SD, 0.39], respectively), indicating that perceived benefits outweighed concerns. Although to our knowledge clinical efficacy has yet to be clearly demonstrated, survivors and parents described positive interest in genetic testing for the risk of developing late effects. Perceived benefits outweighed harms, and the majority of participants would be willing to pay, and wait, for testing. Cancer 2016. © 2016 American Cancer Society. Cancer 2016;122:2876-2885. © 2016 American Cancer Society. © 2016 American

  5. ENRAF Series 854 Advanced Technology Gauge (ATG) with SPU ll Card for Leak Detector Use Acceptance Test Procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SMITH, S.G.

    1999-08-13

    This procedure checks the Enraf gauge received at Hanford is completely functional and has received no shipping damage. This procedure does not certify the gauge operation. The manufacturer certifies gauge operation. This procedure provides acceptance testing for Enraf Series 854 level gauges used to detect leaks in Hanford Waste Storage Tank annuli. The test will verify that the gauge functions according to the manufacturer's instructions and specifications and is properly setup prior to being delivered to the tank farm area. This ATP does not set up the gauge for any specific tank, but is generalized to permit testing the gaugemore » prior to installation package preparation.« less

  6. LPT. Shield test facility (TAN646). Floor plan for water treatment ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Shield test facility (TAN-646). Floor plan for water treatment room on west facade, tank and filter locations in basement along service tunnel and in coupling station. Ralph M. Parsons 1229-17 ANP/GE-6-646-P-2. April 1957. INEEL Index code no. 037-0645/0646-51-693-107387 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  7. 29. PLAN OF THE ARVFS FIELD TEST FACILITY SHOWING BUNKER, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. PLAN OF THE ARVFS FIELD TEST FACILITY SHOWING BUNKER, CABLE CHASE, SHIELDING TANK AND FRAME ASSEMBLY. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-1. INEL INDEX CODE NUMBER: 075 0701 851 151970. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  8. ADVANCED HEAT TRANSFER TEST FACILITY, TRA666A. ELEVATIONS. ROOF FRAMING PLAN. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ADVANCED HEAT TRANSFER TEST FACILITY, TRA-666A. ELEVATIONS. ROOF FRAMING PLAN. CONCRETE BLOCK SIDING. SLOPED ROOF. ROLL-UP DOOR. AIR INTAKE ENCLOSURE ON NORTH SIDE. F.C. TORKELSON 842-MTR-666-A5, 8/1966. INL INDEX NO. 531-0666-00-851-152258, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  9. Computer-aided dispatch--traffic management center field operational test final evaluation plan : WSDOT deployment

    DOT National Transportation Integrated Search

    2003-09-22

    This document presents the Evaluation Teams plan for conducting the evaluation of the FOT in Washington State. A companion document exists for the evaluation of the Utah deployment. This plan includes the experimental design for testing hypotheses...

  10. Vanguard/PLACE experiment system design and test plan

    NASA Technical Reports Server (NTRS)

    Taylor, R. E.

    1973-01-01

    A system design and test plan are described for operational evaluation of the NASA-Goddard position location and aircraft communications equipment (PLACE), at C band (4/6GHz), using NASA's ship, the USNS Vanguard, and the ATS 3 and ATS 5 synchronous satellites. The Sea Test phase, extending from March 29, 1973 to April 15, 1973 was successfully completed; the principal objectives of the experiment were achieved. Typical PLACE-computed, position-location data is shown for the Vanguard. Position location and voice-quality measurements were excellent; ship position was determined within 2 nmi; high-quality, 2-way voice transmissions resulted as determined from audience participation, intelligibility and articulation-index analysis. A C band/L band satellite trilateration experiment is discussed.

  11. 16 CFR Table 3 to Part 1512 - Minimum Acceptable Values for the Quantity A Defined in the Retroreflective Tire and Rim Test...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Minimum Acceptable Values for the Quantity A Defined in the Retroreflective Tire and Rim Test Procedure 3 Table 3 to Part 1512 Commercial Practices... Retroreflective Tire and Rim Test Procedure Observation angle (degrees) Entrance angle (degrees) Minimum...

  12. Peace, Equanimity, and Acceptance in the Cancer Experience (PEACE): validation of a scale to assess acceptance and struggle with terminal illness.

    PubMed

    Mack, Jennifer W; Nilsson, Matthew; Balboni, Tracy; Friedlander, Robert J; Block, Susan D; Trice, Elizabeth; Prigerson, Holly G

    2008-06-01

    The role of emotional acceptance of a terminal illness in end-of-life (EOL) care is not known. The authors developed a measure of peaceful acceptance at the EOL, and evaluated the role of peaceful acceptance in EOL decision-making and care. The authors developed the Peace, Equanimity, and Acceptance in the Cancer Experience (PEACE) questionnaire to measure the extent to which patients with advanced cancer have a sense of peaceful acceptance of their terminal illness. The scale was administered to 160 patients with advanced cancer along with measures of other attributes that hypothetically are related to acceptance, including cognitive acceptance of terminal illness. EOL outcomes in 56 patients who died during the study also were examined. The 12-item PEACE questionnaire had 2 subscales: a 7-item Struggle With Illness subscale (Cronbach alpha = .81) and a 5-item Peaceful Acceptance subscale (alpha = .78). Both subscales were associated with patients' self-reported peacefulness (correlation coefficient [r] = 0.66 for acceptance [P <.0001]; r = -0.37 for struggle [P < .0001]). Struggle With Illness scores were associated with cognitive terminal illness acknowledgment (mean scores, 14.9 vs 12.4 for patients who were not aware that their illness was terminal; P = .001) and with some aspects of advance care planning (living will or healthcare proxy: mean scores, 13.9 vs 11.5; P = .02). In addition, among patients who had died, the use of a feeding tube at the EOL was associated inversely with Peaceful Acceptance (P = .015). The current study indicated that the PEACE questionnaire is a valid and reliable measure of peaceful acceptance and struggle with illness. Scores were associated with some choices for EOL care among patients with advanced cancer. (c) 2008 American Cancer Society.

  13. Acceptance Equipment System Data Acquisition and Processing Utility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fakhro, Rowan

    2015-02-01

    My internship at Sandia National Laboratories took place in the Department of Sensors and Embedded Systems, which is tasked with, among many things, the non-destructive testing of thermal batteries. The Acceptance Equipment System (AES) is a flexible rack system designed to electrically test thermal batteries individually for internal defects before they are stored in the battery stock pile. Aside from individual testing, data acquired by the AES is used for many things including trending and catching outliers within the tolerance levels of a particular battery type, allowing for the development of more refined acceptance requirements and testing procedures.

  14. An Analysis and Plan of Test Development for the Law Enforcement Basic Training Course.

    ERIC Educational Resources Information Center

    Vineberg, Robert; Taylor, John E.

    A test development plan is described to evaluate police enrolled in the law enforcement basic training course developed by California's Commission on Peace Officer Standards and Training (POST). Some general test methodologies are discussed: performance tests, knowledge tests, and situational tests, including role playing simulations and…

  15. Test plan. Task 5, subtask 5.2: Early on-orbit TPSdebris impact tests

    NASA Technical Reports Server (NTRS)

    Greenberg, H. S.

    1994-01-01

    The limitation of damage to, and survival of, the cryogenic tankage during the on-orbit stay despite potential impact of orbital debris, may be a significant discriminator in the RHCTS trade studies described in the TA-1 trade study plan (ref. RHCTS-TSP-1) dated July 29, 1994. The objective of this early phase of an overall debris impact test program is to provide the data to support assessment of the relative suitability of integral and non integral tanks.

  16. A Study of the Communication Capabilities of the OPARS Flight Planning System for Various Levels of Demand.

    DTIC Science & Technology

    1980-03-01

    Oceanography Center (FNOC) is currently testing and evaluating a computerized flight plan system, referred to, for short, as OPARS. This sytem , developed to...replace the Lockheed Jetplan flight plan sytem , provides users at remote sites with direct access to the FNOC computer via 11 telephone lines. The...validity, but only for format. For example, an entry of ABCE , as the four- letter identification code for the destination airfield, would be accepted

  17. Clinical acceptance testing and scanner comparison of ultrasound shear wave elastography.

    PubMed

    Long, Zaiyang; Tradup, Donald J; Song, Pengfei; Stekel, Scott F; Chen, Shigao; Glazebrook, Katrina N; Hangiandreou, Nicholas J

    2018-03-15

    Because of the rapidly growing use of ultrasound shear wave elastography (SWE) in clinical practices, there is a significant need for development of clinical physics performance assessment methods for this technology. This study aims to report two clinical medical physicists' tasks: (a) acceptance testing (AT) of SWE function on ten commercial ultrasound systems for clinical liver application and (b) comparison of SWE measurements of targets across vendors for clinical musculoskeletal application. For AT, ten GE LOGIQ E9 XDclear 2.0 scanners with ten C1-6-D and ten 9L-D transducers were studied using two commercial homogenous phantoms. Five measurements were acquired at two depths for each scanner/transducer pair by two operators. Additional tests were performed to access effects of different coupling media, phantom locations and operators. System deviations were less than 5% of group mean or three times standard deviation; therefore, all systems passed AT. A test protocol was provided based on results that no statistically significant difference was observed between using ultrasound gel and salt water for coupling, among different phantom locations, and that interoperator and intraoperator coefficient of variation was less than 3%. For SWE target measurements, two systems were compared - a Supersonic Aixplorer scanner with a SL10-2 and a SL15-4 transducer, and an abovementioned GE scanner with 9L-D transducer. Two stepped cylinders with diameters of 4.05-10.40 mm were measured both longitudinally and transaxially. Target shear wave speed quantification was performed using an in-house MATLAB program. Using the target shear wave speed deduced from phantom specs as a reference, SL15-4 performed the best at the measured depth. However, it was challenging to reliably measure a 4.05 mm target for either system. The reported test methods and results could provide important information when dealing with SWE-related tasks in the clinical environment. © 2018 The Authors

  18. 78 FR 663 - Decommissioning Planning During Operations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-04

    ...] Decommissioning Planning During Operations AGENCY: Nuclear Regulatory Commission. ACTION: Regulatory guide..., ``Decommissioning Planning During Operations.'' The guide describes a method that the NRC staff considers acceptable for use by holders of licenses in complying with the NRC's Decommissioning Planning Rule (DPR) (76 FR...

  19. 77 FR 41107 - Decommissioning Planning During Operations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-12

    ..., 40, 50, 70, and 72 [NRC-2011-0162] Decommissioning Planning During Operations AGENCY: Nuclear... (DG) 4014, ``Decommissioning Planning During Operations.'' This guide describes a method that the NRC staff considers acceptable for use in complying with the NRC's Decommissioning Planning Rule. The NRC...

  20. Human Factors Process Task Analysis Liquid Oxygen Pump Acceptance Test Procedure for the Advanced Technology Development Center

    NASA Technical Reports Server (NTRS)

    Diorio, Kimberly A.

    2002-01-01

    A process task analysis effort was undertaken by Dynacs Inc. commencing in June 2002 under contract from NASA YA-D6. Funding was provided through NASA's Ames Research Center (ARC), Code M/HQ, and Industrial Engineering and Safety (IES). The John F. Kennedy Space Center (KSC) Engineering Development Contract (EDC) Task Order was 5SMA768. The scope of the effort was to conduct a Human Factors Process Failure Modes and Effects Analysis (HF PFMEA) of a hazardous activity and provide recommendations to eliminate or reduce the effects of errors caused by human factors. The Liquid Oxygen (LOX) Pump Acceptance Test Procedure (ATP) was selected for this analysis. The HF PFMEA table (see appendix A) provides an analysis of six major categories evaluated for this study. These categories include Personnel Certification, Test Procedure Format, Test Procedure Safety Controls, Test Article Data, Instrumentation, and Voice Communication. For each specific requirement listed in appendix A, the following topics were addressed: Requirement, Potential Human Error, Performance-Shaping Factors, Potential Effects of the Error, Barriers and Controls, Risk Priority Numbers, and Recommended Actions. This report summarizes findings and gives recommendations as determined by the data contained in appendix A. It also includes a discussion of technology barriers and challenges to performing task analyses, as well as lessons learned. The HF PFMEA table in appendix A recommends the use of accepted and required safety criteria in order to reduce the risk of human error. The items with the highest risk priority numbers should receive the greatest amount of consideration. Implementation of the recommendations will result in a safer operation for all personnel.