Sample records for accessory glands mags

  1. Male accessory gland proteins induce female monogamy in anopheline mosquitoes.

    PubMed

    Shutt, B; Stables, L; Aboagye-Antwi, F; Moran, J; Tripet, F

    2010-03-01

    The role of male accessory gland (MAG) secretions in inducing refractoriness to further mating in mosquitoes (Diptera: Culicidae) was established in the late 1960s. In a set of simple experiments, MAG extract was injected intra-thoraxically into the hemocoel of virgin Aedes aegypti (L.), Culex pipiens pipiens (L.) and Anopheles quadrimaculatus Say females. This subsequently caused most females to remain unmated when exposed to males. For anophelines these findings were later challenged by a study involving intra-abdominal injections of MAG extracts into Anopheles gambiae Giles s.l. and Anopheles albimanus Wiedmann females, which failed to induce refractoriness to further mating. These findings led to controversy about the respective role of sperm and accessory gland peptides in inducing female monogamy in Anopheles and are at odds with our current understanding of the mating process in Drosophila spp. (Diptera: Drosophillidae) and other dipterans. Here we confirm the function of MAG secretions in anophelines experimentally by showing that intra-thoracic injections in Anopheles stephensi Liston and in the M and S molecular forms of An. gambiae s.s. result in the expected female monogamy. Cross-injections of MAG extracts between the M and S molecular forms of An. gambiae, two cryptic taxa within An. gambiae s.s. which are thought to be undergoing incipient speciation, also elicited effective refractoriness, suggesting that the two sub-taxa have not diverged with regard to sex peptides responsible for female monogamy. Importantly, this also suggests that the rare cases of re-mating following cross-mating observed in this species may not be a form of reproductive barrier between molecular forms.

  2. Male accessory gland substances from Aedes albopictus affect the locomotor activity of Aedes aegypti females

    PubMed Central

    Lima-Camara, Tamara Nunes; Codeço, Claudia Torres; Honório, Nildimar Alves; Bruno, Rafaela Vieira; Peixoto, Alexandre Afranio; Lounibos, Leon Philip

    2013-01-01

    Dengue is one of the world’s most important mosquito-borne diseases and is usually transmitted by one of two vector species: Aedes aegypti or Aedes albopictus . These two diurnal mosquitoes are frequently found coexisting in similar habitats, enabling interactions between adults, such as cross-mating. The objective of this study was to assess cross-mating between Ae. aegypti females and Ae. albopictus males under artificial conditions and evaluate the locomotor activity of Ae. aegypti virgin females injected with male accessory gland (MAG) homogenates to infer the physiological and behavioural responses to interspecific mating. After seven days of exposure, 3.3-16% of Ae. aegypti females mated with Ae. albopictus males. Virgin Ae. aegypti females injected with conspecific and heterospecific MAGs showed a general decrease in locomotor activity compared to controls and were refractory to mating with conspecific males. The reduction in diurnal locomotor activity induced by injections of conspecific or heterospecific MAGs is consistent with regulation of female reproductive activities by male substances, which are capable of sterilising female Ae. aegypti through satyrisation by Ae. albopictus . PMID:24473799

  3. Adenoid Cystic Carcinoma of Accessory Parotid Gland: A Case Report.

    PubMed

    Das, Somdipto; Nayak, Umanath K; Buggavetti, Rahul; Sekhar, Shobana

    2016-05-01

    The accessory parotid gland is salivary gland tissue separated from the main gland at a variable distance. This gland is histologically similar to the main gland, but has a higher incidence of malignant neoplasms than the main gland. Regarding the various malignant neoplasms, studies have shown higher incidences of mucoepidermoid carcinoma, with less than 2% being adenoid cystic carcinoma. We present a case of swelling in the midcheek region that, after clinical examination, was diagnosed as a case of neoplasm of the accessory parotid gland. On the basis of auxiliary investigations including intraoperative frozen section, it was concluded that it was adenoid cystic carcinoma, grade I, and after wide surgical resection, the tumor was removed without undergoing superficial parotidectomy. The patient received postoperative radiotherapy (RT) and was followed for 14 months without any recurrence or substantial facial asymmetry. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Reproductive biology in Anophelinae mosquitoes (Diptera, Culicidae): Fine structure of the female accessory gland.

    PubMed

    Laghezza Masci, Valentina; Di Luca, Marco; Gambellini, Gabriella; Taddei, Anna Rita; Belardinelli, Maria Cristina; Guerra, Laura; Mazzini, Massimo; Fausto, Anna Maria

    2015-07-01

    The morphology and ultrastructure of female accessory reproductive glands of Anopheles maculipennis s.s., Anopheles labranchiae and Anopheles stephensi were investigated by light and electron microscopy. The reproductive system in these species is characterized by two ovaries, two lateral oviducts, a single spermatheca and a single accessory gland. The gland is globular and has a thin duct which empties into the vagina, near the opening of the spermathecal duct. Significant growth of the accessory reproductive gland is observed immediately after blood meal, but not at subsequent digestion steps. At ultrastructural level, the gland consists of functional glandular units belonging to type 3 ectodermal glands. The secretory cells are elongated and goblet shaped, with most of their cytoplasm and large nucleus in the basal part, close to the basement lamella. Finely fibrous electron-transparent material occupies the secretory cavity that is in contact with the end of a short efferent duct (ductule) emerging from the gland duct. The present study is the first detailed description of female accessory gland ultrastructure in Anophelinae and provides insights into the gland's functional role in the reproductive biology of these insects. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Proteomic identification of Drosophila melanogaster male accessory gland proteins, including a pro-cathepsin and a soluble gamma-glutamyl transpeptidase.

    PubMed

    Walker, Michael J; Rylett, Caroline M; Keen, Jeff N; Audsley, Neil; Sajid, Mohammed; Shirras, Alan D; Isaac, R Elwyn

    2006-05-02

    In Drosophila melanogaster, the male seminal fluid contains proteins that are important for reproductive success. Many of these proteins are synthesised by the male accessory glands and are secreted into the accessory gland lumen, where they are stored until required. Previous studies on the identification of Drosophila accessory gland products have largely focused on characterisation of male-specific accessory gland cDNAs from D. melanogaster and, more recently, Drosophila simulans. In the present study, we have used a proteomics approach without any sex bias to identify proteins in D. melanogaster accessory gland secretions. Thirteen secreted accessory gland proteins, including seven new accessory gland proteins, were identified by 2D-gel electrophoresis combined with mass spectrometry of tryptic fragments. They included protein-folding and stress-response proteins, a hormone, a lipase, a serpin, a cysteine-rich protein and two peptidases, a pro-enzyme form of a cathepsin K-like cysteine peptidase and a gamma-glutamyl transpeptidase. Enzymatic studies established that accessory gland secretions contain a cysteine peptidase zymogen that can be activated at low pH. This peptidase may have a role in the processing of female and other male-derived proteins, but is unlikely to be involved in the processing of the sex peptide. gamma-Glutamyl transpeptidases are type II integral membrane proteins; however, the identified AG gamma-glutamyl transpeptidase (GGT-1) is unusual in that it is predicted to be a soluble secreted protein, a prediction that is supported by biochemical evidence. GGT-1 is possibly involved in maintaining a protective redox environment for sperm. The strong gamma-glutamyl transpeptidase activity found in the secretions provides an explanation for the observation that glutamic acid is the most abundant free amino acid in accessory gland secretions of D. melanogaster. We have applied biochemical approaches, not used previously, to characterise

  6. Role of the Accessory Parotid Gland in the Etiology of Parotitis: Statistical Analysis of Sialographic Features

    PubMed Central

    Zhu, Wangyong; Hu, Fengchun; Liu, Xingguang; Guo, Songcan; Tao, Qian

    2016-01-01

    This retrospective study aimed to identify if the existence of the accessory parotid gland correlated with the etiology of parotitis. This may aid the development of better treatment strategies in the future. Sialographic features of cases with parotitis and healthy subjects were reviewed. The chi-square test was used to compare the incidence of accessory parotid gland between the groups. The Student’s t test was used to compare the length of Stensen’s duct, the length from the orifice to the confluence of the accessory duct, and the angle between the accessory duct and Stensen’s duct between the groups. The incidence of accessory parotid gland in patients with parotitis was 71.8% (28/39), which was significantly higher than that in healthy subjects (P = 0.005). Patients with parotitis had a longer Stensen’s duct than healthy subjects (P = 0.003). There was no significant difference in the length from the orifice to the confluence of the accessory duct or the angle between the accessory duct and Stensen’s duct (P = 0.136 and 0.511, respectively) between the groups. The accessory parotid gland might play a role in the pathogenesis of parotitis. The existence of an accessory parotid gland is likely to interfere with salivary flow. Computational fluid dynamics analysis of salivary flow in the ductal system would be useful in future etiologic studies on parotitis. PMID:26913509

  7. Role of the Accessory Parotid Gland in the Etiology of Parotitis: Statistical Analysis of Sialographic Features.

    PubMed

    Zhu, Wangyong; Hu, Fengchun; Liu, Xingguang; Guo, Songcan; Tao, Qian

    2016-01-01

    This retrospective study aimed to identify if the existence of the accessory parotid gland correlated with the etiology of parotitis. This may aid the development of better treatment strategies in the future. Sialographic features of cases with parotitis and healthy subjects were reviewed. The chi-square test was used to compare the incidence of accessory parotid gland between the groups. The Student's t test was used to compare the length of Stensen's duct, the length from the orifice to the confluence of the accessory duct, and the angle between the accessory duct and Stensen's duct between the groups. The incidence of accessory parotid gland in patients with parotitis was 71.8% (28/39), which was significantly higher than that in healthy subjects (P = 0.005). Patients with parotitis had a longer Stensen's duct than healthy subjects (P = 0.003). There was no significant difference in the length from the orifice to the confluence of the accessory duct or the angle between the accessory duct and Stensen's duct (P = 0.136 and 0.511, respectively) between the groups. The accessory parotid gland might play a role in the pathogenesis of parotitis. The existence of an accessory parotid gland is likely to interfere with salivary flow. Computational fluid dynamics analysis of salivary flow in the ductal system would be useful in future etiologic studies on parotitis.

  8. Morphology and protein patterns of honey bee drone accessory glands.

    PubMed

    Cruz-Landim, Carminda da; Dallacqua, Rodrigo Pires

    2005-09-30

    We used light and transmission electron microscopy to examine the morphology of the accessory glands of immature and mature adult males of Apis mellifera L. We also made an electrophoretic analysis of the protein content of the mature gland. The glands of the immature male actively secrete a mucous substance that can be seen in the lumen of the gland of the mature male. This secretion stains with mercury bromophenol blue and with periodic acid-Schiff reaction, which stain glyconjugates. The protein content was higher in the lumen secretion than in the gland wall extracts. The electrophoresis patterns of the wall extracts were different from those of the secretion found in the gland lumen.

  9. Study on development of accessory sex glands in prepubertal kids using two-dimensional ultrasonography

    PubMed Central

    Kumari, Sonu; Luthra, R. A.; Chandolia, R. K.; Kumar, Sandeep; Kumar, Parveen; Devender; Kumar, Ankit; Bishnoi, Nidhi; Bishnoi, Sunil

    2016-01-01

    Aim: The present study was undertaken to study growth pattern of accessory sex glands in prepubertal kids from 2 weeks to 6 months of age using two-dimensional ultrasonography. Materials and Methods: The study was conducted on six Beetal kids. The scanning of accessory sex glands was done in standing position using rectal probe and measurements were recorded. Data collected were statistically analyzed using one-way ANOVA followed by Duncan multiple range test was performed using the SPSS (16.0) system for windows. Results: With the advancement of age all the dimensions of glands increased. Both the lobes of prostate gland showed an increase in width with advancement of age. Width of prostate above the urethra (W1) showed a significant increase at 2, 10, and 20 weeks of age, whereas non-significant increase from 2 to 8, 10 to 19, and 20 to 24 weeks of age was recorded. Width of prostate below the urethra (W2) showed a significant increase at 20 weeks of age, whereas non-significant increase was recorded during rest of period of growth. Left and right bulbourethral gland showed a similar pattern of growth with the advancement of age. The circumference dimensions increased significantly at 2, 16, 20, and 21 weeks of age for both glands. The increase was non-significant from 4 to 14, 16 to 19, and 20 to 23 weeks of age. The same pattern was observed for left and right seminal vesicular gland. Conclusion: Significant growth in three accessory sex glands in prepubertal kids was not observed at the same age. The trend observed was that the prostate was the first gland to show significant growth at 10 weeks of age followed by a significant increase in seminal vesicles and bulbourethral gland at 14 and 16 weeks of age, respectively. PMID:27182127

  10. Study on development of accessory sex glands in prepubertal kids using two-dimensional ultrasonography.

    PubMed

    Kumari, Sonu; Luthra, R A; Chandolia, R K; Kumar, Sandeep; Kumar, Parveen; Devender; Kumar, Ankit; Bishnoi, Nidhi; Bishnoi, Sunil

    2016-04-01

    The present study was undertaken to study growth pattern of accessory sex glands in prepubertal kids from 2 weeks to 6 months of age using two-dimensional ultrasonography. The study was conducted on six Beetal kids. The scanning of accessory sex glands was done in standing position using rectal probe and measurements were recorded. Data collected were statistically analyzed using one-way ANOVA followed by Duncan multiple range test was performed using the SPSS (16.0) system for windows. With the advancement of age all the dimensions of glands increased. Both the lobes of prostate gland showed an increase in width with advancement of age. Width of prostate above the urethra (W1) showed a significant increase at 2, 10, and 20 weeks of age, whereas non-significant increase from 2 to 8, 10 to 19, and 20 to 24 weeks of age was recorded. Width of prostate below the urethra (W2) showed a significant increase at 20 weeks of age, whereas non-significant increase was recorded during rest of period of growth. Left and right bulbourethral gland showed a similar pattern of growth with the advancement of age. The circumference dimensions increased significantly at 2, 16, 20, and 21 weeks of age for both glands. The increase was non-significant from 4 to 14, 16 to 19, and 20 to 23 weeks of age. The same pattern was observed for left and right seminal vesicular gland. Significant growth in three accessory sex glands in prepubertal kids was not observed at the same age. The trend observed was that the prostate was the first gland to show significant growth at 10 weeks of age followed by a significant increase in seminal vesicles and bulbourethral gland at 14 and 16 weeks of age, respectively.

  11. Gene Expression in Human Accessory Lacrimal Glands of Wolfring

    PubMed Central

    Ubels, John L.; Gipson, Ilene K.; Spurr-Michaud, Sandra J.; Tisdale, Ann S.; Van Dyken, Rachel E.; Hatton, Mark P.

    2012-01-01

    Purpose. The accessory lacrimal glands are assumed to contribute to the production of tear fluid, but little is known about their function. The goal of this study was to conduct an analysis of gene expression by glands of Wolfring that would provide a more complete picture of the function of these glands. Methods. Glands of Wolfring were isolated from frozen sections of human eyelids by laser microdissection. RNA was extracted from the cells and hybridized to gene expression arrays. The expression of several of the major genes was confirmed by immunohistochemistry. Results. Of the 24 most highly expressed genes, 9 were of direct relevance to lacrimal function. These included lysozyme, lactoferrin, tear lipocalin, and lacritin. The glands of Wolfring are enriched in genes related to protein synthesis, targeting, and secretion, and a large number of genes for proteins with antimicrobial activity were detected. Ion channels and transporters, carbonic anhydrase, and aquaporins were abundantly expressed. Genes for control of lacrimal function, including cholinergic, adrenergic, vasoactive intestinal polypeptide, purinergic, androgen, and prolactin receptors were also expressed in gland of Wolfring. Conclusions. The data suggest that the function of glands of Wolfring is similar to that of main lacrimal glands and are consistent with secretion electrolytes, fluid, and protein under nervous and hormonal control. Since these glands secrete directly onto the ocular surface, their location may allow rapid response to exogenous stimuli and makes them readily accessible to topical drugs. PMID:22956620

  12. Morphology and development of the accessory glands in various female cricket species.

    PubMed

    Sturm, Robert

    2016-11-01

    The study presents new results with regard to the morphometric and ultrastructural development of the accessory glands in females of the three cricket species Gryllus bimaculatus, Gryllus assimilis, and Acheta domesticus. Furthermore, possible age-dependence of secretory productivity of single organs was analyzed by application of the ligature technique introduced in a previous contribution. Within the first 12 days of the adult phase, the accessory glands of all investigated cricket species exhibit a significant increase in length and width which assumes values between 50 and 100%. This gland growth is rather the result of a continuous increase in cellular volume and less that of mitotic cell propagation. In all species height and width of single gland cells increase by 60-80% within the studied time interval. These changes in morphometry are commonly accompanied by ultrastructural modifications. Total glandular secretion is subject to an increase from the 5th to the 12th day of adult age. This development corresponds well with the number of eggs contemporaneously oviposited into the substrate and thus underlines the hypothesis, according to which the main function of the secretion consists in acting as a lubricant for the facilitated transport of the oocytes through the ovipositor. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Congenital tri-cavernous hemangiomas of the right buccal region, right accessory parotid gland, and masseter muscle region.

    PubMed

    Yang, Tao; Gu, Yongchun; Zhang, Li; Hua, Zequan

    2014-03-01

    We report a rare case of congenital tri-cavernous hemangiomas of the right buccal region, right accessory parotid gland, and masseter muscle region in an adult. The patient, a 25-year-old woman, complained of 3 masses in her right midcheek. Ultrasonographic and computed tomographic findings showed an irregular-shaped mass (multiple calcifications) with a well-defined margin in the masseter muscle region, an ellipse-shaped mass (multiple calcifications) with a well-defined margin in the right buccal region, and a comma-shaped mass (no calcifications) with a well-defined margin separate from the parotid gland in the right accessory parotid gland region. These iconographic findings suggested that the masses were all hemangiomas separately originating from the parotid gland, accessory parotid gland, and masseter muscle. The masses were completely removed through a standard parotid incision without postoperative facial palsy, skin deformity, and difficulty in secreting saliva. Findings from histologic examination of the tumor revealed multiple, thin-walled, and dilated blood vessels, confirming the diagnosis of cavernous hemangiomas. Ultrasonographic and computed tomographic findings were extremely useful in diagnosing the mass/masses as hemangioma before surgery, clarifying relationships between the mass and adjacent structures, and determining the surgical approach to the mass/masses.

  14. Transcriptome analysis to identify genes for peptides and proteins involved in immunity and reproduction from male accessory glands and ejaculatory duct of Bactrocera dorsalis.

    PubMed

    Wei, Dong; Tian, Chuan-Bei; Liu, Shi-Huo; Wang, Tao; Smagghe, Guy; Jia, Fu-Xian; Dou, Wei; Wang, Jin-Jun

    2016-06-01

    In the male reproductive system of insects, the male accessory glands and ejaculatory duct (MAG/ED) are important organs and their primary function is to enhance the fertility of spermatozoa. Proteins secreted by the MAG/ED are also known to induce post-mating changes and immunity responses in the female insect. To understand the gene expression profile in the MAG/ED of the oriental fruit fly Bactrocera dorsalis (Hendel), that is an important pest in fruits, we performed an Illumina-based deep sequencing of mRNA. This yielded 54,577,630 clean reads corresponding to 4.91Gb total nucleotides that were assembled and clustered to 30,669 unigenes (average 645bp). Among them, 20,419 unigenes were functionally annotated to known proteins/peptides in Gene Orthology, Clusters of Orthologous Groups, Kyoto Encyclopedia of Genes and Genomes pathway databases. Typically, many genes were involved in immunity and these included microbial recognition proteins and antimicrobial peptides. Subsequently, the inducible expression of these immunity-related genes was confirmed by qRT-PCR analysis when insects were challenged with immunity-inducible factors, suggesting their function in guaranteeing fertilization success. Besides, we identified some important reproductive genes such as juvenile hormone- and ecdysteroid-related genes in this de novo assembly. In conclusion, this transcriptomic sequencing of B. dorsalis MAG/ED provides insights to facilitate further functional research of reproduction, immunity and molecular evolution of reproductive proteins in this important agricultural pest. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Morphology and Histology of the Ductus Receptaculi and Accessory Glands in the Reproductive Tract of the Female Cricket, Teleogryllus commodus

    PubMed Central

    Sturm, Robert

    2008-01-01

    The morphology and histology of the ductus receptaculi and accessory glands in females of the black field cricket, Teleogryllus commodus Walker (Orthoptera: Gryllidae) are described. Both are reproductive organs situated in the 7th and 8th abdominal segment that join the posterior part of the genital chamber. The ductus receptaculi is a long (up to 25 mm) homogeneous tube, and the accessory glands (total length: 4 to 12 mm) are a complex system of tubes and end lobes with various numbers of ramifications. Based on their external shapes the accessory glands may be subdivided into three distinct regions, a distal region mainly producing the gland's secretion, a middle conducting region, and a basal region serving for the storage and release of the secretory substances into the genital chamber of the female. In histological respects, both organs have an outer muscle coat followed by a basal lamina, one or two cell layers, the cuticular intima, and the inner lumen. The ductus receptaculi is subdivided into three histologically different regions. The region located adjacent to the receptaculum and the region neighbouring the terminal papilla consist of a single, epithelial cell layer that is not secretory. The epithelium of the middle region contains two cell layers, glandular cells and cuticula-forming cells, which are responsible for the production of the cuticular intima. The secretion of the gland cells is released into an extracellular cavity, through which it reaches the lumen via a complex network of canals running through the intima. The histology of the accessory glands is rather homogeneous among the different regions, as one layer of epithelial cells produces both the secretion and the cuticular intima. Histological variations in the distal, middle, and basal gland sections mainly concern the height of the epithelium, the thickness of the basal lamina and the cuticular intima as well as the variable presence of the outer muscle coat. In contrast to the ductus

  16. The accessory parotid gland and facial process of the parotid gland on computed tomography

    PubMed Central

    Ahn, Dongbin; Yeo, Chang Ki; Han, Soon Yong

    2017-01-01

    The purpose of this study was to determine the incidence of an anterior extension of the parotid gland, such as an accessory parotid gland (APG) or facial process (FP) and to evaluate its characteristics on computed tomography (CT) scans. We reviewed CT scans of 1,600 parotid glands from 800 patients. An APG on CT was defined as a soft-tissue mass of the same density as the main parotid gland, located at the anterior part of the main parotid gland, and completely separate from the main parotid gland. An FP was defined as a lobe of the parotid gland protruding anteriorly over the anterior edge of the ramus of the mandible on CT and showing continuity with the main gland. The overall incidence rates and characteristics of APGs and FPs were evaluated according to age, sex, and side. The incidence rates of APGs and FPs were 10.2% (163/1,600) and 28.3% (452/1,600), respectively. The mean size of an APG was 15.8 mm × 5.0 mm and the mean distance from the main parotid gland was 10.5 mm. The FP reached anteriorly between the anterior edge of the mandibular ramus and the anterior border of the masseter muscle in 405 (89.6%) cases, while it extended over the anterior border of the masseter muscle in 47 (10.4%) cases. The incidence rates of APGs and FPs decreased and increased, respectively, with increasing age, showing significant linear correlations. However, the incidence of an anterior extension of the parotid gland (either an APG or an FP) was similar across all age groups. The present study showed that CT might be helpful in identifying anterior extensions of the parotid gland including APGs and FPs. The anatomical information gained from this study contributes to a better understanding of APGs and FPs and how their incidence changes with age. PMID:28915265

  17. Isoform-specific functions of Mud/NuMA mediate binucleation of Drosophila male accessory gland cells.

    PubMed

    Taniguchi, Kiichiro; Kokuryo, Akihiko; Imano, Takao; Minami, Ryunosuke; Nakagoshi, Hideki; Adachi-Yamada, Takashi

    2014-12-20

    In standard cell division, the cells undergo karyokinesis and then cytokinesis. Some cells, however, such as cardiomyocytes and hepatocytes, can produce binucleate cells by going through mitosis without cytokinesis. This cytokinesis skipping is thought to be due to the inhibition of cytokinesis machinery such as the central spindle or the contractile ring, but the mechanisms regulating it are unclear. We investigated them by characterizing the binucleation event during development of the Drosophila male accessory gland, in which all cells are binucleate. The accessory gland cells arrested the cell cycle at 50 hours after puparium formation (APF) and in the middle of the pupal stage stopped proliferating for 5 hours. They then restarted the cell cycle and at 55 hours APF entered the M-phase synchronously. At this stage, accessory gland cells binucleated by mitosis without cytokinesis. Binucleating cells displayed the standard karyokinesis progression but also showed unusual features such as a non-round shape, spindle orientation along the apico-basal axis, and poor assembly of the central spindle. Mud, a Drosophila homolog of NuMA, regulated the processes responsible for these three features, the classical isoform Mud(PBD) and the two newly characterized isoforms Mud(L) and Mud(S) regulated them differently: Mud(L) repressed cell rounding, Mud(PBD) and Mud(S) oriented the spindle along the apico-basal axis, and Mud(S) and Mud(L) repressed central spindle assembly. Importantly, overexpression of Mud(S) induced binucleation even in standard proliferating cells such as those in imaginal discs. We characterized the binucleation in the Drosophila male accessory gland and examined mechanisms that regulated unusual morphologies of binucleating cells. We demonstrated that Mud, a microtubule binding protein regulating spindle orientation, was involved in this binucleation. We suggest that atypical functions exerted by three structurally different isoforms of Mud regulate

  18. Morphology and Ultrastructure of the Accessory Glands in the Female Genital Tract of the House Cricket, Acheta domesticus

    PubMed Central

    Sturm, Robert

    2012-01-01

    The accessory glands in the genital tract of female Acheta domesticus L. (Orthoptera: Gryllidae) were investigated in detail. The glands are situated within the 7th and 8th abdominal segment and lead to the genital chamber lateral to the terminal papilla of the ductus receptaculi. The shape of the gland is characterized by a complex system of tubules, including numerous ramifications. The gland's size ranges from 2 to 4 mm. The epithelium is constructed according to a simple scheme and consists of a cuticular intima at the luminal side, one layer of gland cells, and a basallamina at the outermost side. The observed morphology of the accessory glands widely corresponds with that in other cricket species (e.g., Teleogryllus commodus). This is also true for the structure of a single gland cell, which can be subdivided into a basal part with nucleus and intracellular cisternae, as well as an apical part with all those compartments responsible for the production of the secretion. The secretion itself may be classified as lipophilic and is produced for the first time 4 to 6 days after the imaginai moult. Several endogenic functions of the secretion are discussed (lubricant for oviposition, support for introducing the tube of the spermatophore into the ductus receptaculi, etc.). PMID:23425229

  19. Histological convergent evolution of the accessory submandibular glands in four species of frog-eating bats.

    PubMed

    Tandler, B; Phillips, C J; Nagato, T

    1996-08-01

    The accessory submandibular glands in four species of bats were examined by electron microscopy. These four species represent two independently evolved lineages. The fringe-lipped bat, Trachops cirrhosis, is a Neotropical phyllostomid species, whereas the false vampire bats of southeast Asia, Megaderma lyra and M. spasma, and the heart-nosed bat, Cardioderma cor, of East Africa are megadermatid species. These glands show extreme deviation from typical salivary gland histology: their secretory endpieces are in the form of follicles and their ducts lack the cytological details that permit identification of diverse duct segments. Despite their unusual histology, the secretory endpieces in M. lyra, M. spasma, and C. cor consist of secretory cells that conform to typical secretory cell morphology. In contrast, secretion by follicular cells in T. cirrhosis involves unusual cytoplasmic bodies, and their mitochondria frequently have intracristal crystalloids. Ducts in all four species consist of simple cuboidal to columnar epithelium without basal striations. Follicles and ducts in all four bats are surrounded by numerous myoepithelial cells and are heavily innervated by hypolemmal nerve terminals. Despite their widely separated geographical ranges, all four bat species consume frogs and other vertebrates. Frogs and toads often possess toxic cutaneous glands that provide a chemical defense against predation. It is postulated that the unusual accessory glands in the four frog-eating species secrete toxin-neutralizing salivary factors. The follicular form of the endpieces permits storage of preformed saliva and their coterie of myoepithelial cells and hypolemmal nerve terminals facilitates the sudden and rapid expulsion of saliva into the oral cavity during the consumption of noxious amphibians.

  20. Accessory parotid gland tumours: 24 years of clinical experience.

    PubMed

    Lukšić, I; Suton, P; Rogić, M; Dokuzović, S

    2012-12-01

    The accessory parotid gland (APG) is salivary tissue anterior to and anatomically separate from the parotid gland. APG is a common anatomical variation, but APG tumours are extremely rare. The authors report 6 patients with APG tumours emphasizing the diagnosis, clinical features, indications and rationales for different treatment approaches. Patients with primary tumours of the parotid gland or APG tumours who underwent surgical treatment were included. APG tumours comprised 1.23% of overall parotid tumours (6/488) and had a malignancy rate of 33.3% (2/6). There were three male and three female patients with a mean age of 39 years (range 14-70 years). 5 of 6 parotidectomies entailed superficial lobectomy, while one was a total parotidectomy with composite resection of masseter muscle. Concomitant selective lymphadenectomy was carried out in 3 of 6 patients. At 5 years disease-free survival was 83.3%. Mean follow-up was 161 months (range 14-253 months). Although nonsalivary diagnoses frequently occur in the buccal area, APG tumours should be considered in every differential diagnosis in patients presenting with a mid-cheek mass. From oncosurgical, cosmetic and functional standpoints, treatment by facelift parotidectomy or 'S-incision' with concomitant superficial lobectomy is the recommended surgical approach; high-grade malignancies require total parotidectomy with regional lymphadenectomy. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Alternative delivery of male accessory gland products

    PubMed Central

    2014-01-01

    To increase fertilization success, males transfer accessory gland products (Acps). Several species have evolved unconventional Acps transfer modes, meaning that Acps are transferred separately from the sperm. By surveying the sperm-free Acps transfer cases, we show that these animals have evolved a common strategy to deliver Acps: they all inject Acps directly through the partner’s body wall into the hemolymph. Our review of this mode of Acps transfer reveals another striking similarity: they all transfer sperm in packages or via the skin, which may leave little room for Acps transfer via the conventional route in seminal fluid. We synthesise the knowledge about the function, and the effects in the recipients, of the Acps found in the widely diverse taxa (including earthworms, sea slugs, terrestrial snails, scorpions and salamanders) that inject these substances. Despite the clearly independent evolution of the injection devices, these animals have evolved a common alternative strategy to get their partners to accept and/or use their sperm. Most importantly, the evolution of the injection devices for the delivery of Acps highlights how the latter are pivotal for male reproductive success and, hence, strongly influence sexual selection. PMID:24708537

  2. Aspiration biopsy of mammary analogue secretory carcinoma of accessory parotid gland: another diagnostic dilemma in matrix-containing tumors of the salivary glands.

    PubMed

    Levine, Pascale; Fried, Karen; Krevitt, Lane D; Wang, Beverly; Wenig, Bruce M

    2014-01-01

    Mammary analogue secretory carcinoma (MASC) is a newly described rare salivary gland tumor, which shares morphologic features with acinic cell carcinoma, low-grade cystadenocarcinoma, and secretory carcinoma of the breast. This is the first reported case of MASC of an accessory parotid gland detected by aspiration biopsy with radiologic and histologic correlation in a 34-year-old patient. Sonographically-guided aspiration biopsy showed cytologic features mimicking those of low-grade mucoepidermoid carcinoma, including sheets of bland epithelial cells, dissociated histiocytoid cells with intracytoplasmic mucinous material, and spindle cells lying in a web-like matrix. Histologic sections showed a circumscribed tumor with microcystic spaces lined by bland uniform epithelial cells and containing secretory material. The tumor cells expressed mammaglobin and BRST-2. The cytologic features, differential diagnosis, and pitfalls are discussed. The pathologic stage was pT1N0. The patient showed no evidence of disease at 1 year follow-up. Copyright © 2012 Wiley Periodicals, Inc.

  3. Transcriptional Profiles of Mating-Responsive Genes from Testes and Male Accessory Glands of the Mediterranean Fruit Fly, Ceratitis capitata

    PubMed Central

    Scolari, Francesca; Gomulski, Ludvik M.; Ribeiro, José M. C.; Siciliano, Paolo; Meraldi, Alice; Falchetto, Marco; Bonomi, Angelica; Manni, Mosè; Gabrieli, Paolo; Malovini, Alberto; Bellazzi, Riccardo; Aksoy, Serap; Gasperi, Giuliano; Malacrida, Anna R.

    2012-01-01

    Background Insect seminal fluid is a complex mixture of proteins, carbohydrates and lipids, produced in the male reproductive tract. This seminal fluid is transferred together with the spermatozoa during mating and induces post-mating changes in the female. Molecular characterization of seminal fluid proteins in the Mediterranean fruit fly, Ceratitis capitata, is limited, although studies suggest that some of these proteins are biologically active. Methodology/Principal Findings We report on the functional annotation of 5914 high quality expressed sequence tags (ESTs) from the testes and male accessory glands, to identify transcripts encoding putative secreted peptides that might elicit post-mating responses in females. The ESTs were assembled into 3344 contigs, of which over 33% produced no hits against the nr database, and thus may represent novel or rapidly evolving sequences. Extraction of the coding sequences resulted in a total of 3371 putative peptides. The annotated dataset is available as a hyperlinked spreadsheet. Four hundred peptides were identified with putative secretory activity, including odorant binding proteins, protease inhibitor domain-containing peptides, antigen 5 proteins, mucins, and immunity-related sequences. Quantitative RT-PCR-based analyses of a subset of putative secretory protein-encoding transcripts from accessory glands indicated changes in their abundance after one or more copulations when compared to virgin males of the same age. These changes in abundance, particularly evident after the third mating, may be related to the requirement to replenish proteins to be transferred to the female. Conclusions/Significance We have developed the first large-scale dataset for novel studies on functions and processes associated with the reproductive biology of Ceratitis capitata. The identified genes may help study genome evolution, in light of the high adaptive potential of the medfly. In addition, studies of male recovery dynamics in terms

  4. A mucin-like glycoprotein identified by MAG (mouse ascites Golgi) antibodies. Menstrual cycle-dependent localization in human endometrium.

    PubMed Central

    Kliman, H. J.; Feinberg, R. F.; Schwartz, L. B.; Feinman, M. A.; Lavi, E.; Meaddough, E. L.

    1995-01-01

    Human endometrial glands synthesize and secrete a high molecular weight mucin-like glycoprotein in a menstrual cycle-dependent fashion. A novel moiety within this Golgi-associated glycoprotein is strongly reactive with IgG antibodies in numerous murine ascites, and has been termed MAG (mouse ascites Golgi). Immunohistochemical staining of 201 endometrial biopsies revealed the following patterns: MAG first appeared in the Golgi on cycle day 5, peaked on day 15, was present on the surface of the luminal epithelium between days 17 and 19, and was no longer detectable after day 19. MAG was also present in cervical, prostate, seminal vesicle, and lacrimal glands, pancreatic acinar cells, gall bladder and bile duct epithelium, and certain cells of the salivary and sweat glands. Interestingly, only tissues from blood group A individuals exhibited this staining. As a common link among all these cell types is the expression of mucins, we speculated that the MAG epitope could be a mucin-associated blood group A-related epitope. This hypothesis was tested by absorption experiments with a variety of glycoconjugates and erythrocytes and by immunoblots of MAG-rich material. The absorption studies demonstrated that only type III porcine mucin (< 1% sialic acid) and blood type A or AB erythrocytes were able to absorb the anti-MAG antibody. Inasmuch as N-acetyl-galactosamine alone, the terminal blood group A carbohydrate, did not block MAG antibody binding, the MAG epitope appears to involve N-acetylgalactosamine plus other determinants. Immunoblots of endometrial extracts and saliva from blood type A individuals revealed MAG-reactive material with a molecular weight > 200 kd under reducing conditions. Because the MAG epitope appears on the endometrial surface during the purported implantation window, we speculate that mucin-like epitopes could play a role in the earliest apposition phases of conceptus-endometrial interaction. Images Figure 1 Figure 2 Figure 4 Figure 5 Figure 6

  5. Malignant neoplasm in the axilla of a male: suspected primary carcinoma of an accessory mammary gland.

    PubMed

    Takeyama, Hiroshi; Takahashi, Hiroyuki; Tabei, Isao; Fukuchi, Osamu; Nogi, Hiroko; Kinoshita, Satoki; Uchida, Ken; Morikawa, Toshiaki

    2010-04-01

    A 58-year-old Japanese male patient visited our hospital for evaluation of an elastic hard mass, measuring 80 x 50 mm, in the right axillary area. Incisional biopsy for suspected malignancy was performed, and histopathologic examination by hematoxylin-eosin (H&E) staining yielded a diagnosis of poorly differentiated adenocarcinoma metastatic from an unknown primary. As the tumor was immunohistochemically positive for both ER and PgR, metastatic breast cancer was strongly suspected. Ultrasonography, CT, and MRI revealed no evidence of tumors in the bilateral mammary glands. Detailed examination of the head and neck region, lung, and upper and lower gastrointestinal tract also revealed no evidence of a primary tumor. After chemotherapy, the patient underwent tumor resection with axillary lymph node dissection. On the basis of the histological features of H&E-stained specimens and immunohistochemistry of the resected tumor, this case was diagnosed as breast cancer of unknown origin in a male. The tumor could have been an axillary lymph node metastasis from an occult breast carcinoma, or primary cancer arising in an accessory mammary gland.

  6. Gross morphology and ultrastructure of salivary glands of the mute cicada Karenia caelatata Distant (Hemiptera: Cicadoidea).

    PubMed

    Zhong, Hai-ying; Wei, Cong; Zhang, Ya-lin

    2013-02-01

    Salivary glands of the cicada Karenia caelatata Distant were investigated using light microscopy and transmission electron microscopy. The salivary glands are paired structures and consist of principal glands and accessory glands. The principal gland is subdivided into anterior lobe and posterior lobe; the former contains about 34-39 long digitate lobules, while the latter contains approximately 30-33 long digitate lobules and 13-22 short digitate lobules. These short digitate lobules, about one fifth or sixth as long as the long digitate lobules, locate at the base of the long digitate lobules of posterior lobe. All of these digitate lobules vary in size, disposition, length and shape. The anterior lobe and the posterior lobe are connected by an anterior-posterior duct. Two efferent salivary ducts, which connect with the posterior lobe, fuse to form a common duct. The accessory gland is composed of three parts: a greatly tortuous and folded accessory salivary tube, a circlet of gular gland constituting of several acini of the same size, and a non-collapsible accessory salivary duct. The digitate lobules and gular glands possess secretory cells containing abundant secretory granules vary in size, shape, and electron density, as might indicate different materials are synthesized in different secretory regions. The anterior-posterior duct lines with a player of cuticular lining, and cells beneath the cuticular lining lack of basal infoldings, as suggests the duct serves just to transport secretions. The accessory salivary duct is lined with cuticular lining; cells of the duct have well developed basal infoldings associated with abundant mitochondria, as probably suggests the duct is a reabsorptive region of ions. The cells of the accessory salivary tube possess deep basal infoldings and well developed apical dense microvilli, indicating the cells of the tube are secretory in function. Concentric lamellar structures and a peculiar structure with abundant membrane

  7. On the effect specificity of accessory gland products transferred by the love-dart of land snails.

    PubMed

    Lodi, Monica; Koene, Joris M

    2016-05-13

    Sexual selection favours the evolution of male bioactive substances transferred during mating to enhance male reproductive success by affecting female physiology. These effects are mainly well documented for separate-sexed species. In simultaneous hermaphrodites, one of the most peculiar examples of transfer of such substances is via stabbing a so-called love-dart in land snails. This calcareous stylet delivers mucous products produced by accessory glands into the mate's haemolymph. In Cornu aspersum, this mucus temporarily causes two changes in the recipient. First, the spermatophore uptake into the spermatophore-receiving organ, called diverticulum, is probably favoured by contractions of this organ. Second, the amount of stored sperm increases by contractions of the copulatory canal, which close off the tract leading to the sperm digesting organ. However, it has yet to be determined whether these effects are similar across species, which would imply a common strategy of the dart in increasing male reproductive success. We performed a cross-reactivity test to compare the in vitro response of the diverticulum and copulatory canal of C. aspersum (Helicidae) to its own and other species' mucus (seven helicids and one bradybaenid). We found that the contractions in the diverticulum were only induced by dart mucus of certain species, while the copulatory canal responded equally to all but one species' mucus tested. In addition, we report a newly-discovered effect causing the shortening of the diverticulum, which is also only caused by dart mucus of certain species. The advantage seems to be a distance reduction to the sperm storage organ. All these findings are the first to shed light on the evolution of the different functions of accessory gland products in dart-bearing species. These functions may be achieved via common physiological changes caused by the substances contained in the dart mucus, since the responses evoked were similar across species' mucus. Moreover

  8. Regucalcin Expression in Bovine Tissues and Its Regulation by Sex Steroid Hormones in Accessory Sex Glands

    PubMed Central

    Starvaggi Cucuzza, Laura; Divari, Sara; Mulasso, Chiara; Biolatti, Bartolomeo; Cannizzo, Francesca T.

    2014-01-01

    Regucalcin (RGN) is a mammalian Ca2+-binding protein that plays an important role in intracellular Ca2+ homeostasis. Recently, RGN has been identified as a target gene for sex steroid hormones in the prostate glands and testis of rats and humans, but no studies have focused on RGN expression in bovine tissues. Thus, in the present study, we examined RGN mRNA and protein expression in the different tissues and organs of veal calves and beef cattle. Moreover, we investigated whether RGN expression is controlled through sex steroid hormones in bovine target tissues, namely the bulbo-urethral and prostate glands and the testis. Sex steroid hormones are still illegally used in bovine husbandry to increase muscle mass. The screening of the regulation and function of anabolic sex steroids via modified gene expression levels in various tissues represents a new approach for the detection of illicit drug treatments. Herein, we used quantitative PCR, western blot and immunohistochemistry analyses to demonstrate RGN mRNA and protein expression in bovine tissues. In addition, estrogen administration down-regulated RGN gene expression in the accessory sex glands of veal calves and beef cattle, while androgen treatment reduced RGN gene expression only in the testis. The confirmation of the regulation of RGN gene expression through sex steroid hormones might facilitate the potential detection of hormone abuse in bovine husbandry. Particularly, the specific response in the testis suggests that this tissue is ideal for the detection of illicit androgen administration in veal calves and beef cattle. PMID:25415588

  9. [Fibroadenoma in an accessory breast. A case of polythelia and fibroadenoma in the left breast region and a perivulvar accessory breast].

    PubMed

    Degrell, I

    1979-08-02

    The case of a 32-year-old female patient with multiple malformations (hare-lip, polythelia, fibroadenoma in an accessory mammary gland) and independent of these, another fibroadenoma in the breast is reported. The fibroadenoma developing in the accessory breast around the vulva, diagnosed by means of aspiration biopsy cytology, should be payed special attention. This case also confirms the applicability in preoperative diagnostics of aspiration biopsy cytology, a method which has proved to be effective for years.

  10. Social cues of sperm competition influence accessory reproductive gland size in a promiscuous mammal.

    PubMed

    Lemaître, Jean-François; Ramm, Steven A; Hurst, Jane L; Stockley, Paula

    2011-04-22

    Theory predicts that males should increase overall investment in ejaculate expenditure with increasing levels of sperm competition. Since ejaculate production is costly, we may expect males to tailor their reproductive investment according to anticipated levels of sperm competition. Here, we investigate plasticity in ejaculate investment in response to cues of population average levels of sperm competition in a promiscuous mammal, the bank vole (Myodes glareolus). We manipulated the social experience of experimental subjects during sexual development via differential exposure to the odour of rival males, to simulate conditions associated with relatively high or low average levels of sperm competition. Males exposed to a high level of competition developed larger major accessory reproductive glands (seminal vesicles) than those that experienced a low level of competition, suggesting that an increased investment in the production of copulatory plugs and/or mating rate may be beneficial at relatively high sperm competition levels. However, investment in sperm production, testis size and sperm motility were not altered according to social experience. Our findings emphasize the importance of non-sperm components of the ejaculate in mammalian postcopulatory sexual selection, and add to the growing evidence linking plasticity in reproductive traits to social cues of sperm competition.

  11. Synthesis, depletion and cell-type expression of a protein from the male accessory glands of the dengue vector mosquito Aedes aegypti

    PubMed Central

    Alfonso-Parra, Catalina; Avila, Frank W.; Deewatthanawong, Prasit; Sirot, Laura K.; Wolfner, Mariana F.; Harrington, Laura C.

    2014-01-01

    Aedes aegypti males transfer sperm and seminal fluid proteins (Sfps), primarily produced by male accessory glands (AGs), to females during mating. When collectively injected or transplanted into females, AG tissues and/or seminal fluid homogenates have profound effects on Aedes female physiology and behavior. To identify targets and design new strategies for vector control, it is important to understand the biology of the AGs. Thus, we examined characteristics of AG secretion and development in Ae. aegypti, using the AG-specific seminal fluid protein, AAEL010824, as a marker. We showed that AAEL010824 is first detectable by 12h post-eclosion, and increases in amount over the first 3 days of adult life. We then showed that the amount of AAEL0010824 in the AG decreases after mating, with each successive mating depleting it further; by 5 successive matings with no time for recovery, its levels are very low. AAEL010824 levels in a depleted male are replenished by 48hr post-mating. In addition to examining the level of AAEL010824 protein, we also characterized the expression of its gene. We did this by making a transgenic mosquito line that carries an Enhanced Green Fluorescence Protein (EGFP) fused to the AAEL0010824 promoter that we defined here. We showed that AAEL010824 is expressed in the anterior cells of the accessory glands, and that its RNA levels also respond to mating. In addition to further characterizing AAEL010824 expression, our results with the EGFP fusion provide a promoter for driving AG expression. By providing this information on the biology of an important male reproductive tissue and the production of one of its seminal proteins, our results lay the foundation for future work aimed at identifying novel targets for mosquito population control. PMID:25107876

  12. Prevalence of human papilloma virus infection in patients with male accessory gland infection.

    PubMed

    La Vignera, S; Vicari, E; Condorelli, R A; Franchina, C; Scalia, G; Morgia, G; Perino, A; Schillaci, R; Calogero, A E

    2015-04-01

    The frequency of human papillomavirus (HPV) infection in the semen of patients with male accessory gland infection (MAGI) was evaluated. One hundred infertile patients with MAGI were classified into group A: patients with an inflammatory MAGI (n = 48) and group B: patients with a microbial form (n = 52). Healthy age-matched fertile men (34.0 ± 4.0 years) made up the control group (n = 20). Amplification of HPV DNA was carried out by HPV-HS Bio nested polymerase chain reaction for the detection of HPV DNA sequences within the L1 ORF. Ten patients in group A (20.8%) and 15 patients in group B (28.8%) had a HPV infection; two controls (10.0%) had HPV infection. Patients with MAGI had a significantly higher frequency of HPV infection compared with controls; patients with a microbial MAGI had significantly higher frequency of HPV infection compared with patients with an inflammatory form (both P < 0.05). Patients with MAGI and HPV had a slight, but significantly lower sperm progressive motility and normal morphology compared with patients with MAGI HPV-negative (P < 0.05). Elevated frequency of HPV infection occurred in patients with MAGI, suggesting that HPV should be investigated in the diagnostic work-up of these patients. Copyright © 2014 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  13. High level of sperm competition may increase transfer of accessory gland products carried by the love dart of land snails.

    PubMed

    Lodi, Monica; Staikou, Alexandra; Janssen, Ruben; Koene, Joris M

    2017-12-01

    Postcopulatory adaptations that increase reproductive success compared to rivals, like the transfer of accessory gland products that promote paternity, are common when sperm competition occurs among males. In land snails, the dart shooting behavior and its adaptive significance, in promoting individual fitness through enhanced paternity of the successful dart shooter, have been considered such an adaptation. The fitness result gained is mediated by the transfer of mucus components on the love dart capable of altering the physiology of the receiver's reproductive tract. In this context, dart shooting and mucus transfer could be considered as processes targeted by sexual selection. While the effect of dart mucus is beneficial for the dart user, so far it has remained unknown whether its transport is greater when snails experience a higher level of sperm competition. Here, we report results of a study on inter- and intraspecific variations of dart and mucus gland morphometry, considered to be traits reflecting the ability of snails to adjust the production and transfer of mucus under varying sperm competition scenarios. We investigated four populations with different densities from four dart-bearing species, Arianta arbustorum , Cepaea nemoralis , Cornu aspersum, and Helix lucorum . The results indicate that different adaptations of these traits occur among the studied species that all seem to achieve the same goal of transferring more mucus when sperm competition is higher. For example, the presence of longer and more branched mucous glands or an increase in dart surface most likely reflect increased mucus production and enhanced ability of mucus transport, respectively. Interestingly, the species for which the use of the dart is reported to be facultative, A. arbustorum , did not show any variation among the examined traits. To conclude, sexual selection in the form of sperm competition intensity seems to be an important selective force for these simultaneously

  14. Morphophysiology and ultrastructure of the male reproductive accessory glands of the bats Carollia perspicillata, Glossophaga soricina and Phyllostomus discolor (Chiroptera: Phyllostomidae).

    PubMed

    Martins, Fabiane F; Beguelini, Mateus R; Puga, Cintia C I; Morielle-Versute, Eliana; Vilamaior, Patricia S L; Taboga, Sebastião R

    2016-07-01

    The male reproductive accessory glands (RAGs) are important organs that contribute to the secretion of different substances that composed the ejaculate. Despite this important function, their composition, anatomy and function vary widely between species. Thus, the RAGs of three species of phyllostomid bats were morphologically and ultrastructurally characterized and compared in this study. The RAGs of the three analyzed species are composed of a prostate and a pair of bulbourethral glands (BG). In all species, the prostate is composed of three well-defined regions (ventral, dorsolateral and dorsal regions). The ventral region showed an atypical epithelium (undefined) with no obvious cellular limits and a holocrine PAS-positive secretion. The dorsolateral region of Carollia perspicillata and Phyllostomus discolor showed a pseudostratified cubic morphology, and that from Glossophaga soricina had a columnar morphology endowed with cytoplasmic projections and stereocilia. The dorsal region of the three analyzed species is composed of a pseudostratified columnar epithelium endowed with stereocilia; however, G. soricina also presented cytoplasmic projections in the apical portions of the secretory cells similar to those in the dorsolateral region. The BG of the three analyzed species are composed of a pseudostratified columnar epithelium including basal and PAS-positive secretory cells. In conclusion, this study morphologically and ultrastructurally characterized the RAGs of three species of phyllostomid bats, demonstrating the presence of a novel third prostatic region in species of this family. The results also showed the absence of seminal vesicles and ampullary glands, and better characterized the holocrine pattern of the prostatic ventral region, which is unique to bats. Copyright © 2016 Elsevier GmbH. All rights reserved.

  15. Gene expression changes in male accessory glands during ageing are accompanied by reproductive decline in Drosophila melanogaster.

    PubMed

    Koppik, Mareike; Fricke, Claudia

    2017-12-01

    Senescence is accompanied by loss of reproductive functions. Here, we studied reproductive ageing in Drosophila melanogaster males and asked whether the expected decline in male reproductive success is due to diminished functionality of the male accessory gland (AG). The male AG produces the majority of seminal fluid proteins (SFPs) transferred to the female at mating. SFPs induce female postmating changes and are key to male reproductive success. We measured age-dependent gene expression changes for five representative SFP genes in males from four different age groups ranging from 1 to 6 weeks after eclosion. Simultaneously, we also measured male reproductive success in postmating traits mediated by transfer of these five SFPs. We found a decreased in male SFP gene expression with advancing age and an accompanying decline in male postmating success. Hence, male reproductive senescence is associated with a decline in functionality of the male AG. While overall individual SFP genes decreased in expression, our results point towards the idea that the composition of an ejaculate might change with male age as the rate of change was variable for those five genes. © 2017 John Wiley & Sons Ltd.

  16. Identity and transfer of male reproductive gland proteins of the dengue vector mosquito, Aedes aegypti: potential tools for control of female feeding and reproduction

    PubMed Central

    Sirot, Laura K.; Poulson, Rebecca L.; McKenna, M. Caitlin; Girnary, Hussein; Wolfner, Mariana F.; Harrington, Laura C.

    2009-01-01

    Male reproductive gland proteins (mRGPs) impact the physiology and/or behavior of mated females in a broad range of organisms. We sought to identify mRGPs of the yellow fever mosquito, Aedes aegypti, the primary vector of dengue and yellow fever viruses. Earlier studies with Ae. aegypti demonstrated that “matrone” (a partially purified male reproductive accessory gland substance) or male accessory gland fluid injected into virgin female Ae. aegypti affect female sexual refractoriness, blood feeding and digestion, flight, ovarian development, and oviposition. Using bioinformatic comparisons to Drosophila melanogaster accessory gland proteins and mass spectrometry of proteins from Ae. aegypti male accessory glands and ejaculatory ducts (AG/ED) and female reproductive tracts, we identified 63 new putative Ae. aegypti mRGPs. Twenty-one of these proteins were found in the reproductive tract of mated females, but not of virgin females, suggesting that they are transferred from males to females during mating. Most of the putative mRGPs fall into the same protein classes as mRGPs in other organisms, although some appear to be evolving rapidly and lack identifiable homologs in Culex pipiens, Anopheles gambiae, and D. melanogaster. Our results identify candidate male-derived molecules that may have an important influence on behavior, survival and reproduction of female mosquitoes. PMID:18207079

  17. Vasoactive intestinal polypeptide (VIP) innervation of the human eyelid glands.

    PubMed

    Seifert, P; Spitznas, M

    1999-06-01

    This study was conducted to obtain morphological proof of innervating nerve fibres in the glands of the human eyelid (accessory lacrimal glands of Wolfring, meibomian glands, goblet cells, glands of Zeis, glands of Moll, sweat glands, glands of lanugo hair follicles) and identification of the secretomotorically active neuropeptide vasoactive intestinal polypeptide (VIP) as a common transmitter. Epoxy-embedded ultrathin sections of tissue samples from human eyelids were studied using electron microscopy. Paraffin sections fixed in Bouin-Hollande solution were immunostained with rabbit antiserum against VIP. With the electron microscope we were able to identify nerves in the glandular stroma of all the glands examined with the exception of goblet cells. Intraepithelial single axons were only seen in the parenchyma of Wolfring glands. The morphological findings corresponded with the immunological finding of VIP-positive, nerve-like structures in the same locations, with the exception of lanugo hair follicle glands, and goblet cells. Our findings indicate that the glands of the eyelids and main lacrimal gland represent a functional unit with VIP as a possible common stimulating factor. Copyright 1999 Academic Press.

  18. The pineal gland from development to function.

    PubMed

    Sapède, Dora; Cau, Elise

    2013-01-01

    The pineal gland is a small neuroendocrine organ whose main and most conserved function is the nighttime secretion of melatonin. In lower vertebrates, the pineal gland is directly photosensitive. In contrast, in higher vertebrates, the direct photosensitivity of the pineal gland had been lost. Rather, the action of this gland as a relay between environmental light conditions and body functions involves reception of light information by the retina. In parallel to this sensory regression, the pineal gland (and its accessory organs) appears to have lost several functions in relation to light and temperature, which are important in lower vertebrate species. In humans, the functions of the pineal gland overlap with the functions of melatonin. They are extremely widespread and include general effects both on cell protection and on more precise functions, such as sleep and immunity. Recently, the role of melatonin has received a considerable amount of attention due to increased cancer risk in shift workers and the discovery that patients suffering from neurodegenerative diseases, autism, or depression exhibit abnormal melatonin rhythms. © 2013 Elsevier Inc. All rights reserved.

  19. Demystifying Mag-Lev.

    ERIC Educational Resources Information Center

    Ruiz, Ernest; And Others

    1991-01-01

    Presented are classroom activities in which students explore the potential use of magnetic levitation for transportation purposes. The advantages of using a MagLev transportation system instead of conventional trains are discussed. Directions for designing and building a MagLev track and circuit are provided. (KR)

  20. Polythelia pilosa: a particular form of accessory mammary tissue.

    PubMed

    Camacho, F; González-Cámpora, R

    1998-01-01

    The old Kajawa classification which considered eight possible forms of aberrant mammary tissue has been recently modified into a simpler one that considers this condition only when there is glandular parenchyma or when the aberrant tissue is not a glandular tissue but a nipple, an areola or both. This new classification disregards 'polythelia pilosa' defined as an 'isolated patch of hairs only'. To demonstrate that polythelia pilosa is at least a marker of subjacent accessory mammary tissue and, consequently, that the term should be incorporated into the current classification. Among 72 cases of aberrant or accessory mammary tissue, we have studied 14 cases (7 men and 7 women) that were clinically diagnosed as 'visible isolated patches of hairs, apparently without pigmentation nor structures of areola or nipple'. We excised such isolated patches in 3 women. The histopathological examination showed an acanthotic and hyperpigmented epithelium with central depression closed by keratin plugs; in the dermis there were follicles with hairs surrounded by hypertrophic sebaceous glands. In the deepest portion, abundant secretory glomerules and excretory ducts of apocrine gland type could be observed. Since the biopsy of isolated patches of hairs demonstrated structures of either areolar or apocrine glandular tissue, we think that the term 'polythelia pilosa' should be reinstated into the classification as it is at least a marker of true aberrant mammary structures in men and hirsute women.

  1. Lipid rafts mediate the interaction between myelin-associated glycoprotein (MAG) on myelin and MAG-receptors on neurons.

    PubMed

    Vinson, Mary; Rausch, Oliver; Maycox, Peter R; Prinjha, Rab K; Chapman, Debra; Morrow, Rachel; Harper, Alex J; Dingwall, Colin; Walsh, Frank S; Burbidge, Stephen A; Riddell, David R

    2003-03-01

    The interaction between myelin-associated glycoprotein (MAG), expressed at the periaxonal membrane of myelin, and receptors on neurons initiates a bidirectional signalling system that results in inhibition of neurite outgrowth and maintenance of myelin integrity. We show that this involves a lipid-raft to lipid-raft interaction on opposing cell membranes. MAG is exclusively located in low buoyancy Lubrol WX-insoluble membrane fractions isolated from whole brain, primary oligodendrocytes, or MAG-expressing CHO cells. Localisation within these domains is dependent on cellular cholesterol and occurs following terminal glycosylation in the trans-Golgi network, characteristics of association with lipid rafts. Furthermore, a recombinant form of MAG interacts specifically with lipid-raft fractions from whole brain and cultured cerebellar granule cells, containing functional MAG receptors GT1b and Nogo-66 receptor and molecules required for transduction of signal from MAG into neurons. The localisation of both MAG and MAG receptors within lipid rafts on the surface of opposing cells may create discrete areas of high avidity multivalent interaction, known to be critical for signalling into both cell types. Localisation within lipid rafts may provide a molecular environment that facilitates the interaction between MAG and multiple receptors and also between MAG ligands and molecules involved in signal transduction.

  2. Male accessory gland inflammation prevalence in type 2 diabetic patients with symptoms possibly reflecting autonomic neuropathy

    PubMed Central

    Condorelli, Rosita A; Vicari, Enzo; Calogero, Aldo E; La Vignera, Sandro

    2014-01-01

    Male accessory gland inflammation or infection (MAGI) is a potentially underdiagnosed complication of type 2 diabetes (DM2); specifically, we reported in a recent study that the frequency of MAGI was 43% among DM2 patients. In previous studies, we have demonstrated that diabetic autonomic neuropathy (DAN) is associated with a peculiar ultrasound characterization of the seminal vesicles (SVs) in DM2 patients. The aim of the present study was to evaluate the frequency of MAGI in two different categories of DM2 patients (i.e. patients with and without symptoms that possibly reflect DAN) and the respective ultrasound characterizations. Sixty DM2 patients with a mean (± s.e.m.) age of 42.0 ± 6.0 years (range: 34–47 years) were classified according to the presence or the absence of symptoms that could possibly reflect DAN (group A: DM2 with symptoms possibly reflecting DAN, n = 28 patients and group B: DM2 without symptoms possibly reflecting DAN, n = 32 patients). The patients in Group A exhibited a significantly higher frequency of MAGI compared with those in group B patients (P < 0.05); moreover, the Group A patients exhibited a significantly higher frequency of ultrasound signs suggestive of vesiculitis (P < 0.05). Finally, the concentrations of lymphocytes but not the concentrations of the leukocytes in the semen were significantly higher (P < 0.05) in group A compared with group B. PMID:24799635

  3. Physiological responses and characteristics of sperm collected after electroejaculation or transrectal ultrasound-guided massage of the accessory sex glands in anesthetized mouflons (Ovis musimon) and Iberian ibexes (Capra pyrenaica).

    PubMed

    Ungerfeld, Rodolfo; López-Sebastián, Antonio; Esteso, Milagros; Pradiee, Jorgea; Toledano-Díaz, Adolfo; Castaño, Cristina; Labrador, Beatriz; Santiago-Moreno, Julián

    2015-10-15

    The objective was to characterize the stress response and the seminal parameters obtained with electroejaculation (EE) or transrectal ultrasound-guided massage of the accessory sex glands (TUMASG) in two captive but nondomestic ruminants, the mouflons and the Iberian ibex under general anesthesia. In mouflons, the physiological responses (heart and respiratory rate, rectal temperature, cortisol, creatine kinase, potassium and glucose concentrations) changed similarly with both procedures. The TUMASG procedure was faster than EE in mouflons (21.7 ± 1.4 vs. 12.4 ± 1.2 minutes, P < 0.01). In ibexes, respiratory rate, cortisol and creatine kinase concentration changes were greater with EE than with TUMASG (final respiratory rate: 62.7 ± 5.5 vs. 38.1 ± 5.6 breaths/min [P < 0.05]; final cortisol: 51.4 ± 5.1 vs. 25.3 ± 5.6 ng/mL [P < 0.001]; and final creatine kinase: 300.9 ± 99.9 vs. 87.1 ± 16.9 U/L [P < 0.001]). Electroejaculation provided better results in some sperm parameters (mouflons: sperm score: 3.4 ± 0.3 vs. 2.6 ± 0.2 [P < 0.01]; total number of sperm ejaculated: 982.4 ± 299 vs. 710.0 ± 542.2 [P < 0.05]; ibexes: sperm with progressive motility: 47.7 ± 6.2 vs. 20.5 ± 8.3 [P < 0.05]). The transrectal ultrasound-guided massage of the accessory sex glands appears to be an alternative technique to collect sperm from wild ruminants, reducing the need for electrical stimuli and thus decreasing the undesired responses of EE in the more sensitive species. On the other hand, better fresh sperm may be collected with EE. However, TUMASG provides practical advantages in animal welfare, firstly in these wild species more sensible to stress management and capture myopathy. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. THOR Fluxgate Magnetometer (MAG)

    NASA Astrophysics Data System (ADS)

    Nakamura, Rumi; Eastwood, Jonathan; Magnes, Werner; Carr, Christopher, M.; O'Brien, Helen, L.; Narita, Yasuhito; K, Chen, Christopher H.; Berghofer, Gerhard; Valavanoglou, Aris; Delva, Magda; Plaschke, Ferdinand; Cupido, Emanuele; Soucek, Jan

    2017-04-01

    Turbulence Heating ObserveR (THOR) is the first mission ever flown in space dedicated to plasma turbulence. The fluxgate Magnetometer (MAG) measures the background to low frequency magnetic field. The high sensitivity measurements of MAG enable to characterize the nature of turbulent fluctuations as well as the large-scale context. MAG will provide the reference system for determining anisotropy of field fluctuations, pitch-angle and gyro-phase of particles. The design of the magnetometer consists of two tri-axial sensors and the related magnetometer electronics; the electronics are hosted on printed circuit boards in the common electronics box of the fields and wave processor (FWP). A fully redundant two- sensor system mounted on a common boom and the new miniaturized low noise design based on MMS and Solar Orbiter instruments enable accurate measurement throughout the region of interest for THOR science. The usage of the common electronics hosted by FWP guarantees to fulfill the required timing accuracy with other fields measurements. These improvements are important to obtain precise measurements of magnetic field, which is essential to estimate basic plasma parameters and correctly identify the spatial and temporal scales of the turbulence. Furthermore, THOR MAG provides high quality data with sufficient overlap with the Search Coil Magnetometer (SCM) in frequency space to obtain full coverage of the wave forms over all the frequencies necessary to obtain the full solar wind turbulence spectrum from MHD to kinetic range with sufficient accuracy. We discuss the role of MAG in THOR key science questions and present the new developments during Phase A such as the finalised instrument design, MAG relevant requirement, and new calibraion schemes.

  5. Sexual dimorphism and developmental change of the salivary glands in adult Culicoides variipennis (Diptera: Ceratopogonidae).

    PubMed

    Perez de Leon, A A; Lloyd, J E; Tabachnick, W J

    1994-11-01

    Salivary glands of adult male and female Culicoides variipennis (Coquillett) were sexually dimorphic when examined by phase contrast light microscopy. Female salivary glands were larger and more complex than those in males. Each female gland consisted of a main gland, which was subdivided into a proximal neck and a distal body with reference to the salivary duct, and four accessory glands. Each male salivary gland consisted of a pear-shaped body with a constriction, or neck, that divided it into a proximal and a distal portion, with reference to the salivary duct. Salivary glands of both sexes increased in length from emergence to day 3, followed by a sex-specific pattern of decrease. Based on these morphological observations, we suggest that the salivary glands of female C. variipennis are specialized in the production of secretory materials for blood-feeding.

  6. Protein and Peptide Composition of Male Accessory Glands of Apis mellifera Drones Investigated by Mass Spectrometry

    PubMed Central

    Gorshkov, Vladimir; Blenau, Wolfgang; Koeniger, Gudrun; Römpp, Andreas; Vilcinskas, Andreas; Spengler, Bernhard

    2015-01-01

    In honeybees, reproductive females usually mate early in their life with more than 10 males in free flight, often within 10 minutes, and then store male gametes for up to five years. Because of the extreme polyandry and mating in free flight special adaptations in males are most likely. We present here the results of an investigation of the protein content of four types of male reproductive glands from the Western honeybee (Apis mellifera) drone, namely seminal vesicles (secretion in ejaculate), as well as bulbus, cornua and mucus glands (secretions for the mating plug). Using high resolution and accuracy mass spectrometry and a combination of database searching and de novo sequencing techniques it was possible to identify 50 different proteins in total, inside all mentioned glands, except in the mucus gland. Most of the proteins are unique for a specific gland type, only one of them (H9KEY1/ATP synthase subunit O) was found in three glands, and 7 proteins were found in two types of glands. The identified proteins represent a wide variety of biological functions and can be assigned to several physiological classes, such as protection, energy generation, maintaining optimal conditions, associated mainly with vesicula seminalis; signaling, cuticle proteins, icarpin and apolipoproteins located mainly in the bulbus and cornua glands; and some other classes. Most of the discovered proteins were not found earlier during investigation of semen, seminal fluid and tissue of reproductive glands of the bee drone. Moreover, we provide here the origin of each protein. Thus, the presented data might shed light on the role of each reproductive gland. PMID:25955586

  7. Protein and Peptide Composition of Male Accessory Glands of Apis mellifera Drones Investigated by Mass Spectrometry.

    PubMed

    Gorshkov, Vladimir; Blenau, Wolfgang; Koeniger, Gudrun; Römpp, Andreas; Vilcinskas, Andreas; Spengler, Bernhard

    2015-01-01

    In honeybees, reproductive females usually mate early in their life with more than 10 males in free flight, often within 10 minutes, and then store male gametes for up to five years. Because of the extreme polyandry and mating in free flight special adaptations in males are most likely. We present here the results of an investigation of the protein content of four types of male reproductive glands from the Western honeybee (Apis mellifera) drone, namely seminal vesicles (secretion in ejaculate), as well as bulbus, cornua and mucus glands (secretions for the mating plug). Using high resolution and accuracy mass spectrometry and a combination of database searching and de novo sequencing techniques it was possible to identify 50 different proteins in total, inside all mentioned glands, except in the mucus gland. Most of the proteins are unique for a specific gland type, only one of them (H9KEY1/ATP synthase subunit O) was found in three glands, and 7 proteins were found in two types of glands. The identified proteins represent a wide variety of biological functions and can be assigned to several physiological classes, such as protection, energy generation, maintaining optimal conditions, associated mainly with vesicula seminalis; signaling, cuticle proteins, icarpin and apolipoproteins located mainly in the bulbus and cornua glands; and some other classes. Most of the discovered proteins were not found earlier during investigation of semen, seminal fluid and tissue of reproductive glands of the bee drone. Moreover, we provide here the origin of each protein. Thus, the presented data might shed light on the role of each reproductive gland.

  8. Comparative genomics of Roseobacter clade bacteria isolated from the accessory nidamental gland of Euprymna scolopes

    PubMed Central

    Collins, Andrew J.; Fullmer, Matthew S.; Gogarten, Johann P.; Nyholm, Spencer V.

    2015-01-01

    The accessory nidamental gland (ANG) of the female Hawaiian bobtail squid, Euprymna scolopes, houses a consortium of bacteria including members of the Flavobacteriales, Rhizobiales, and Verrucomicrobia but is dominated by members of the Roseobacter clade (Rhodobacterales) within the Alphaproteobacteria. These bacteria are deposited into the jelly coat of the squid’s eggs, however, the function of the ANG and its bacterial symbionts has yet to be elucidated. In order to gain insight into this consortium and its potential role in host reproduction, we cultured 12 Rhodobacterales isolates from ANGs of sexually mature female squid and sequenced their genomes with Illumina sequencing technology. For taxonomic analyses, the ribosomal proteins of 79 genomes representing both roseobacters and non-roseobacters along with a separate MLSA analysis of 33 housekeeping genes from Roseobacter organisms placed all 12 isolates from the ANG within two groups of a single Roseobacter clade. Average nucelotide identity analysis suggests the ANG isolates represent three genera (Leisingera, Ruegeria, and Tateyamaria) comprised of seven putative species groups. All but one of the isolates contains a predicted Type VI secretion system, which has been shown to be important in secreting signaling and/or effector molecules in host–microbe associations and in bacteria–bacteria interactions. All sequenced genomes also show potential for secondary metabolite production, and are predicted to be involved with the production of acyl homoserine lactones (AHLs) and/or siderophores. An AHL bioassay confirmed AHL production in three tested isolates and from whole ANG homogenates. The dominant symbiont, Leisingera sp. ANG1, showed greater viability in iron-limiting conditions compared to other roseobacters, possibly due to higher levels of siderophore production. Future comparisons will try to elucidate novel metabolic pathways of the ANG symbionts to understand their putative role in host

  9. MagAO: status and science

    NASA Astrophysics Data System (ADS)

    Morzinski, Katie M.; Close, Laird M.; Males, Jared R.; Hinz, Phil M.; Esposito, Simone; Riccardi, Armando; Briguglio, Runa; Follette, Katherine B.; Pinna, Enrico; Puglisi, Alfio; Vezilj, Jennifer; Xompero, Marco; Wu, Ya-Lin

    2016-07-01

    "MagAO" is the adaptive optics instrument at the Magellan Clay telescope at Las Campanas Observatory, Chile. MagAO has a 585-actuator adaptive secondary mirror and 1000-Hz pyramid wavefront sensor, operating on natural guide stars from R-magnitudes of -1 to 15. MagAO has been in on-sky operation for 166 nights since installation in 2012. MagAO's unique capabilities are simultaneous imaging in the visible and infrared with VisAO and Clio, excellent performance at an excellent site, and a lean operations model. Science results from MagAO include the first ground-based CCD image of an exoplanet, demonstration of the first accreting protoplanets, discovery of a new wide-orbit exoplanet, and the first empirical bolometric luminosity of an exoplanet. We describe the status, report the AO performance, and summarize the science results. New developments reported here include color corrections on red guide stars for the wavefront sensor; a new field stop stage to facilitate VisAO imaging of extended sources; and eyepiece observing at the visible-light diffraction limit of a 6.5-m telescope. We also discuss a recent hose failure that led to a glycol coolant leak, and the recovery of the adaptive secondary mirror (ASM) after this recent (Feb. 2016) incident.

  10. Iron oxide nanoparticles modulate heat shock proteins and organ specific markers expression in mice male accessory organs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sundarraj, Kiruthika; Raghunath, Azhwar; Panneerse

    With increased industrial utilization of iron oxide nanoparticles (Fe{sub 2}O{sub 3}-NPs), concerns on adverse reproductive health effects following exposure have been immensely raised. In the present study, the effects of Fe{sub 2}O{sub 3}-NPs exposure in the seminal vesicle and prostate gland were studied in mice. Mice were exposed to two different doses (25 and 50 mg/kg) of Fe{sub 2}O{sub 3}-NPs along with the control and analyzed the expressions of heat shock proteins (HSP60, HSP70 and HSP90) and organ specific markers (Caltrin, PSP94, and SSLP1). Fe{sub 2}O{sub 3}-NPs decreased food consumption, water intake, and organo-somatic index in mice with elevated ironmore » levels in serum, urine, fecal matter, seminal vesicle and prostate gland. FTIR spectra revealed alterations in the functional groups of biomolecules on Fe{sub 2}O{sub 3}-NPs treatment. These changes are accompanied by increased lactate dehydrogenase levels with decreased total protein and fructose levels. The investigation of oxidative stress biomarkers demonstrated a significant increase in reactive oxygen species, nitric oxide, lipid peroxidation, protein carbonyl content and glutathione peroxidase with a concomitant decrement in the glutathione and ascorbic acid in the male accessory organs which confirmed the induction of oxidative stress. An increase in NADPH-oxidase-4 with a decrease in glutathione-S-transferase was observed in the seminal vesicle and prostate gland of the treated groups. An alteration in HSP60, HSP70, HSP90, Caltrin, PSP94, and SSLP1 expression was also observed. Moreover, accumulation of Fe{sub 2}O{sub 3}-NPs brought pathological changes in the seminal vesicle and prostate gland of treated mice. These findings provide evidence that Fe{sub 2}O{sub 3}-NPs could be an environmental risk factor for reproductive disease. - Highlights: • Fe{sub 2}O{sub 3}-NPs caused adverse effects on the seminal vesicle and prostate gland of mice • Heat shock proteins (Hsp60, 70 and 90

  11. Implementation of cargo MagLev in the United States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rose, Chris R; Peterson, Dean E; Leung, Eddie M

    2008-01-01

    Numerous studies have been completed in the United States, but no commercial MagLev systems have been deployed. Outside the U.S., MagLev continues to attract funding for research, development and implementation. A brief review of recent global developments in MagLev technology is given followed by the status of MagLev in the U.S. The paper compares the cost of existing MagLev systems with other modes of transport, notes that the near-term focus of MagLev development in the U.S. should be for cargo, and suggests that future MagLev systems should be for very high speed cargo. The Los Angeles to Port of Losmore » Angeles corridor is suggested as a first site for implementation. The benefits of MagLev are described along with suggestions on how to obtain funding.« less

  12. Antigen induced inhibition of autoimmune response to rat male accessory glands: role of thymocytes on the efferent phase of the suppression.

    PubMed

    Ferro, M E; Romero-Piffiguer, M; Rivero, V; Yranzo-Volonte, N; Correa, S; Riera, C M

    1991-01-01

    In the present study, we report that Cy-sensitive, MRAG-adherent spleen mononuclear (SpM) inductor-phase T suppressor (Ts) cells obtained from rats pretreated with low doses of a purified fraction (FI) of rat male accessory gland antigens (RAG) are mainly OX19+ and W3/25+. Furthermore, thymocytes from rats pretreated with FI of RAG restore the suppression of the autoimmune response to RAG autoantigens in irradiated recipients of SpM inductor-phase Ts cells. In contrast, thymocytes from rats pretreated with rat heart saline extract (unrelated antigen) did not recuperate the suppression of the autoimmune response detected by macrophage migration inhibitory factor (MIF) and delayed-type hypersensitivity. The suppressor thymocytes did not directly exert their inhibitory effect because they were not effective to suppress the autoimmune response to RAG autoantigens when irradiated recipients did not receive SpM inductor-phase Ts cells. The effect of these thymocytes was found in PNA--but not in PNA+ thymic cell population. The perithymic injection of Toxoplasma gondii did block their suppressor activity. The present report clearly shows an active participation of thymus in the efferent phase of the suppressor circuit that controls the autoimmune response to MRAG. The implications of these findings are discussed.

  13. Comparative Transcriptome Analysis of the Accessory Sex Gland and Testis from the Chinese Mitten Crab (Eriocheir sinensis)

    PubMed Central

    He, Lin; Jiang, Hui; Cao, Dandan; Liu, Lihua; Hu, Songnian; Wang, Qun

    2013-01-01

    The accessory sex gland (ASG) is an important component of the male reproductive system, which functions to enhance the fertility of spermatozoa during male reproduction. Certain proteins secreted by the ASG are known to bind to the spermatozoa membrane and affect its function. The ASG gene expression profile in Chinese mitten crab (Eriocheir sinensis) has not been extensively studied, and limited genetic research has been conducted on this species. The advent of high-throughput sequencing technologies enables the generation of genomic resources within a short period of time and at minimal cost. In the present study, we performed de novo transcriptome sequencing to produce a comprehensive transcript dataset for the ASG of E. sinensis using Illumina sequencing technology. This analysis yielded a total of 33,221,284 sequencing reads, including 2.6 Gb of total nucleotides. Reads were assembled into 85,913 contigs (average 218 bp), or 58,567 scaffold sequences (average 292 bp), that identified 37,955 unigenes (average 385 bp). We assembled all unigenes and compared them with the published testis transcriptome from E. sinensis. In order to identify which genes may be involved in ASG function, as it pertains to modification of spermatozoa, we compared the ASG and testis transcriptome of E. sinensis. Our analysis identified specific genes with both higher and lower tissue expression levels in the two tissues, and the functions of these genes were analyzed to elucidate their potential roles during maturation of spermatozoa. Availability of detailed transcriptome data from ASG and testis in E. sinensis can assist our understanding of the molecular mechanisms involved with spermatozoa conservation, transport, maturation and capacitation and potentially acrosome activation. PMID:23342039

  14. The Magnetics Information Consortium (MagIC)

    NASA Astrophysics Data System (ADS)

    Johnson, C.; Constable, C.; Tauxe, L.; Koppers, A.; Banerjee, S.; Jackson, M.; Solheid, P.

    2003-12-01

    The Magnetics Information Consortium (MagIC) is a multi-user facility to establish and maintain a state-of-the-art relational database and digital archive for rock and paleomagnetic data. The goal of MagIC is to make such data generally available and to provide an information technology infrastructure for these and other research-oriented databases run by the international community. As its name implies, MagIC will not be restricted to paleomagnetic or rock magnetic data only, although MagIC will focus on these kinds of information during its setup phase. MagIC will be hosted under EarthRef.org at http://earthref.org/MAGIC/ where two "integrated" web portals will be developed, one for paleomagnetism (currently functional as a prototype that can be explored via the http://earthref.org/databases/PMAG/ link) and one for rock magnetism. The MagIC database will store all measurements and their derived properties for studies of paleomagnetic directions (inclination, declination) and their intensities, and for rock magnetic experiments (hysteresis, remanence, susceptibility, anisotropy). Ultimately, this database will allow researchers to study "on the internet" and to download important data sets that display paleo-secular variations in the intensity of the Earth's magnetic field over geological time, or that display magnetic data in typical Zijderveld, hysteresis/FORC and various magnetization/remanence diagrams. The MagIC database is completely integrated in the EarthRef.org relational database structure and thus benefits significantly from already-existing common database components, such as the EarthRef Reference Database (ERR) and Address Book (ERAB). The ERR allows researchers to find complete sets of literature resources as used in GERM (Geochemical Earth Reference Model), REM (Reference Earth Model) and MagIC. The ERAB contains addresses for all contributors to the EarthRef.org databases, and also for those who participated in data collection, archiving and

  15. Effect of male accessory gland secretions on sensitivity of porcine sperm acrosomes to cold shock, initiation of motility and loss of cytoplasmic droplets.

    PubMed

    Berger, T; Clegg, E D

    1985-05-01

    Hyaluronidase release was used as an index of acrosomal membrane damage during cold shock of epididymal boar sperm and ejaculated sperm from intact and vesiculectomized boars. Sperm were also incubated with seminal plasma from intact and vasectomized boars to examine the contributions of male accessory gland secretions. Acrosomal membranes of epididymal sperm were more resistant to cold shock than those of ejaculated sperm. Only 36% of the hyaluronidase released by ejaculated sperm was released by the epididymal sperm in spite of similar hyaluronidase content of the sperm. Preincubation of epididymal sperm in seminal plasma from both intact and vasectomized boars increased resistance to cold shock by 60 to 80%. Initial dilution of epididymal sperm with seminal plasma, rather than Ringer-fructose buffer, was associated with low progressive motility and with retention of cytoplasmic droplets. In contrast, acrosomal membranes of ejaculated sperm from intact and vesiculectomized boars exhibited similar sensitivity to cold shock, releasing hyaluronidase capable of forming .20 and .19 mumol N-acetylglucosamine from hyaluronic acid/10(8) sperm in 8 min. Moreover, seminal plasma from vasectomized boars had no effect on acrosomal sensitivity to cold shock of ejaculated sperm from vesiculectomized boars.

  16. A National MagLev Transportation System

    NASA Technical Reports Server (NTRS)

    Wright, Michael R.

    2003-01-01

    The case for a national high-speed magnetic-levitation (MagLev) transportation system is presented. Focus is on current issues facing the country, such as national security, the economy, transportation, technology, and the environment. NASA s research into MagLev technology for launch assist is also highlighted. Further, current socio-cultural norms regarding motor-vehicle-based transportation systems are questioned in light of the problems currently facing the U.S. The multidisciplinary benefits of a long-distance MagLev system support the idea that such a system would be an important element of a truly multimodal U.S. transportation infrastructure.

  17. Tangential gunshot wound with MagSafe ammunition.

    PubMed

    Rapkiewicz, Amy V; Tamburri, Robert; Basoa, Mark E; Catanese, Charles A

    2005-09-01

    MagSafe ammunition is a type of unconventional prefragmented ammunition. A fatal tangential gunshot wound involving MagSafe ammunition is presented. The ammunition and wound characteristics are discussed.

  18. Computed tomographic imaging characteristics of the normal canine lacrimal glands

    PubMed Central

    2014-01-01

    Background The canine lacrimal gland (LG) and accessory lacrimal gland of the third eyelid (TEG) are responsible for production of the aqueous portion of the precorneal tear film. Immune-mediated, toxic, neoplastic, or infectious processes can affect the glands directly or can involve adjacent tissues, with secondary gland involvement. Disease affecting these glands can cause keratoconjunctivitis sicca, corneal ulcers, and loss of vision. Due to their location in the orbit, these small structures are difficult to evaluate and measure, making cross-sectional imaging an important diagnostic tool. The detailed cross-sectional imaging appearance of the LG and TEG in dogs using computed tomography (CT) has not been reported to date. Results Forty-two dogs were imaged, and the length, width, and height were measured and the volume calculated for the LGs & TEGs. The glands were best visualized in contrast-enhanced CT images. The mean volume of the LG was 0.14 cm3 and the TEG was 0.1 cm3. The mean height, width, and length of the LG were, 9.36 mm, 4.29 mm, and 9.35 mm, respectively; the corresponding values for the TEG was 2.02 mm, 9.34 mm, and 7.90 mm. LG and TEG volume were positively correlated with body weight (p < 0.05). Conclusions Contrast-enhanced CT is a valuable tool for noninvasive assessment of canine lacrimal glands. PMID:24886364

  19. Fine-needle aspiration biopsy of large-cell undifferentiated carcinoma of the salivary glands: presentation of two cases, literature review, and differential cytodiagnosis of high-grade salivary gland malignancies.

    PubMed

    Moore, J G; Bocklage, T

    1998-07-01

    Primary undifferentiated carcinoma of the salivary glands is a rare, high-grade neoplasm which accounts for a very small number (1-5.5%) of malignant salivary gland tumors. The large-cell variant (LCU) is less well-characterized than the small-cell form. We report on the fine-needle aspiration (FNA) biopsy findings of 2 cases of LCU, one arising in the parotid gland, and the other in a buccal mucosa accessory salivary gland. The 2 cases were similar in composition: isolated and loosely cohesive large cells with abundant cytoplasm, and variability pleomorphic nuclei with prominent nucleoli. One case also featured multinucleated tumor giant cells and macrophage polykaryons; the latter has not previously been described in FNA biopsies of LCU. There was no evidence of squamous, myoepithelial, or widespread mucinous differentiation by morphological, cytochemical, or immunohistochemical analyses (focal rare mucin production identified on special stains in one case). The differential diagnosis is lengthy and consists of other high-grade primary salivary gland malignancies as well as metastatic lesions, including melanoma. The pattern of immunohistochemical reactivity (positive keratin, negative S-100, and HMB-45 antigens), and lack of conspicuous mucin production of significant lymphoidinfiltrate, were useful in establishing the correct diagnosis.

  20. Heterogeneity of Polyneuropathy Associated with Anti-MAG Antibodies

    PubMed Central

    Magy, Laurent; Kaboré, Raphaël; Mathis, Stéphane; Lebeau, Prisca; Ghorab, Karima; Caudie, Christiane; Vallat, Jean-Michel

    2015-01-01

    Polyneuropathy associated with IgM monoclonal gammopathy and anti-myelin associated glycoprotein (MAG) antibodies is an immune-mediated demyelinating neuropathy. The pathophysiology of this condition is likely to involve anti-MAG antibody deposition on myelin sheaths of the peripheral nerves and it is supposed to be distinct from chronic inflammatory demyelinating neuropathy (CIDP), another immune-mediated demyelinating peripheral neuropathy. In this series, we have retrospectively reviewed clinical and laboratory findings from 60 patients with polyneuropathy, IgM gammopathy, and anti-MAG antibodies. We found that the clinical picture in these patients is highly variable suggesting a direct link between the monoclonal gammopathy and the neuropathy. Conversely, one-third of patients had a CIDP-like phenotype on electrodiagnostic testing and this was correlated with a low titer of anti-MAG antibodies and the absence of widening of myelin lamellae. Our data suggest that polyneuropathy associated with anti-MAG antibodies is less homogeneous than previously said and that the pathophysiology of the condition is likely to be heterogeneous as well with the self-antigen being MAG in most of the patients but possibly being another component of myelin in the others. PMID:26065001

  1. The Laser Accessory Market

    NASA Astrophysics Data System (ADS)

    Desai, Ashvin

    1988-09-01

    Wandering through the exhibit hall yesterday, I noticed that if you look at the laser companies and if you look at the accessory companies, there are pretty much the same number of accessory booths as well as the laser companies. There was one difference. Laser company booths are all sexy looking, very flashy, big booths. Whereas if you look at the accessories booths, they were small, not so prominent.

  2. 14 CFR 23.1163 - Powerplant accessories.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... section, be sealed to prevent contamination of the engine oil system and the accessory system. (b... engine is hazardous when malfunctioning occurs, a means to prevent rotation without interfering with the... Controls and Accessories § 23.1163 Powerplant accessories. (a) Each engine mounted accessory must— (1) Be...

  3. 14 CFR 23.1163 - Powerplant accessories.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... section, be sealed to prevent contamination of the engine oil system and the accessory system. (b... engine is hazardous when malfunctioning occurs, a means to prevent rotation without interfering with the... Controls and Accessories § 23.1163 Powerplant accessories. (a) Each engine mounted accessory must— (1) Be...

  4. 14 CFR 23.1163 - Powerplant accessories.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... section, be sealed to prevent contamination of the engine oil system and the accessory system. (b... engine is hazardous when malfunctioning occurs, a means to prevent rotation without interfering with the... Controls and Accessories § 23.1163 Powerplant accessories. (a) Each engine mounted accessory must— (1) Be...

  5. 14 CFR 23.1163 - Powerplant accessories.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... section, be sealed to prevent contamination of the engine oil system and the accessory system. (b... engine is hazardous when malfunctioning occurs, a means to prevent rotation without interfering with the... Controls and Accessories § 23.1163 Powerplant accessories. (a) Each engine mounted accessory must— (1) Be...

  6. Variation in sperm displacement and its association with accessory gland protein loci in Drosophila melanogaster.

    PubMed

    Clark, A G; Aguadé, M; Prout, T; Harshman, L G; Langley, C H

    1995-01-01

    Genes that influence mating and/or fertilization success may be targets for strong natural selection. If females remate frequently relative to the duration of sperm storage and rate of sperm use, sperm displacement may be an important component of male reproductive success. Although it has long been known that mutant laboratory stocks of Drosophila differ in sperm displacement, the magnitude of the naturally occurring genetic variation in this character has not been systematically quantified. Here we report the results of a screen for variation in sperm displacement among 152 lines of Drosophilia melanogaster that were made homozygous for second and/or third chromosomes recovered from natural populations. Sperm displacement was assayed by scoring the progeny of cn;bw females that had been mated sequentially to cn;bw and tested males in either order. Highly significant differences were seen in both the ability to displace sperm that is resident in the female's reproductive tract and in the ability to resist displacement by subsequent sperm. Most lines exhibited nearly complete displacement, having nearly all progeny sired by the second male, but several lines had as few as half the progeny fathered by the second male. Lines that were identified in the screen for naturally occurring variation in sperm displacement were also characterized for single-strand conformation polymorphisms (SSCP) at seven accessory gland protein (Acp) genes, Glucose dehydrogenase (Gld), and Esterase-6 (Est-6). Acp genes encode proteins that are in some cases known to be transmitted to the female in the seminal fluid and are likely candidates for genes that might mediate the phenomenon of sperm displacement. Significant associations were found between particular Acp alleles at four different loci (Acp26Aa/Ab, Acp29B, Acp36DE and Acp53E) and the ability of males to resist displacement by subsequent sperm. There was no correlation between the ability to displace resident sperm and the ability

  7. MAG-EPA reduces severity of DSS-induced colitis in rats.

    PubMed

    Morin, Caroline; Blier, Pierre U; Fortin, Samuel

    2016-05-15

    Ulcerative colitis (UC) is a chronic disease characterized by diffuse inflammation of the intestinal mucosa of the large bowel. Omega-3 (ω3) fatty acid supplementation has been associated with a decreased production of inflammatory cytokines involved in UC pathogenesis. The aim of this study was to determine the preventive and therapeutic potential of eicosapentaenoic acid monoglyceride (MAG-EPA) in an in vivo rats model of UC induced by dextran sulfate sodium (DSS). DSS rats were untreated or treated per os with MAG-EPA. Morphological, histological, and biochemical analyses were performed following MAG-EPA administrations. Morphological and histological analyses revealed that MAG-EPA pretreatment (12 days pre-DSS) and treatment (6 days post-DSS) exhibited strong activity in reducing severity of disease in DSS rats. Following MAG-EPA administrations, tissue levels of the proinflammatory cytokines TNF-α, IL-1β, and IL-6 were markedly lower compared with rats treated only with DSS. MAG-EPA per os administration decrease neutrophil infiltration in colon tissues, as depicted by myelohyperoxidase activity. Results also revealed a reduced activation of NF-κB pathways correlated with a decreased expression of COX-2 in colon homogenates derived from MAG-EPA-pretreated and treated rats. Tension measurements performed on colon tissues revealed that contractile responses to methacholine and relaxing effect induced by sodium nitroprusside were largely increased following MAG-EPA treatment. The combined treatment of MAG-EPA and vitamin E displayed an antagonistic effect on anti-inflammatory properties of MAG-EPA in DSS rats. Copyright © 2016 the American Physiological Society.

  8. MAG4 versus alternative techniques for forecasting active region flare productivity.

    PubMed

    Falconer, David A; Moore, Ronald L; Barghouty, Abdulnasser F; Khazanov, Igor

    2014-05-01

    MAG4 is a technique of forecasting an active region's rate of production of major flares in the coming few days from a free magnetic energy proxy. We present a statistical method of measuring the difference in performance between MAG4 and comparable alternative techniques that forecast an active region's major-flare productivity from alternative observed aspects of the active region. We demonstrate the method by measuring the difference in performance between the "Present MAG4" technique and each of three alternative techniques, called "McIntosh Active-Region Class," "Total Magnetic Flux," and "Next MAG4." We do this by using (1) the MAG4 database of magnetograms and major flare histories of sunspot active regions, (2) the NOAA table of the major-flare productivity of each of 60 McIntosh active-region classes of sunspot active regions, and (3) five technique performance metrics (Heidke Skill Score, True Skill Score, Percent Correct, Probability of Detection, and False Alarm Rate) evaluated from 2000 random two-by-two contingency tables obtained from the databases. We find that (1) Present MAG4 far outperforms both McIntosh Active-Region Class and Total Magnetic Flux, (2) Next MAG4 significantly outperforms Present MAG4, (3) the performance of Next MAG4 is insensitive to the forward and backward temporal windows used, in the range of one to a few days, and (4) forecasting from the free-energy proxy in combination with either any broad category of McIntosh active-region classes or any Mount Wilson active-region class gives no significant performance improvement over forecasting from the free-energy proxy alone (Present MAG4). Quantitative comparison of performance of pairs of forecasting techniques Next MAG4 forecasts major flares more accurately than Present MAG4 Present MAG4 forecast outperforms McIntosh AR Class and total magnetic flux.

  9. MAG4 versus alternative techniques for forecasting active region flare productivity

    PubMed Central

    Falconer, David A; Moore, Ronald L; Barghouty, Abdulnasser F; Khazanov, Igor

    2014-01-01

    MAG4 is a technique of forecasting an active region's rate of production of major flares in the coming few days from a free magnetic energy proxy. We present a statistical method of measuring the difference in performance between MAG4 and comparable alternative techniques that forecast an active region's major-flare productivity from alternative observed aspects of the active region. We demonstrate the method by measuring the difference in performance between the “Present MAG4” technique and each of three alternative techniques, called “McIntosh Active-Region Class,” “Total Magnetic Flux,” and “Next MAG4.” We do this by using (1) the MAG4 database of magnetograms and major flare histories of sunspot active regions, (2) the NOAA table of the major-flare productivity of each of 60 McIntosh active-region classes of sunspot active regions, and (3) five technique performance metrics (Heidke Skill Score, True Skill Score, Percent Correct, Probability of Detection, and False Alarm Rate) evaluated from 2000 random two-by-two contingency tables obtained from the databases. We find that (1) Present MAG4 far outperforms both McIntosh Active-Region Class and Total Magnetic Flux, (2) Next MAG4 significantly outperforms Present MAG4, (3) the performance of Next MAG4 is insensitive to the forward and backward temporal windows used, in the range of one to a few days, and (4) forecasting from the free-energy proxy in combination with either any broad category of McIntosh active-region classes or any Mount Wilson active-region class gives no significant performance improvement over forecasting from the free-energy proxy alone (Present MAG4). Key Points Quantitative comparison of performance of pairs of forecasting techniques Next MAG4 forecasts major flares more accurately than Present MAG4 Present MAG4 forecast outperforms McIntosh AR Class and total magnetic flux PMID:26213517

  10. BinMag: Widget for comparing stellar observed with theoretical spectra

    NASA Astrophysics Data System (ADS)

    Kochukhov, O.

    2018-05-01

    BinMag examines theoretical stellar spectra computed with Synth/SynthMag/Synmast/Synth3/SME spectrum synthesis codes and compare them to observations. An IDL widget program, BinMag applies radial velocity shift and broadening to the theoretical spectra to account for the effects of stellar rotation, radial-tangential macroturbulence, instrumental smearing. The code can also simulate spectra of spectroscopic binary stars by appropriate coaddition of two synthetic spectra. Additionally, BinMag can be used to measure equivalent width, fit line profile shapes with analytical functions, and to automatically determine radial velocity and broadening parameters. BinMag interfaces with the Synth3 (ascl:1212.010) and SME (ascl:1202.013) codes, allowing the user to determine chemical abundances and stellar atmospheric parameters from the observed spectra.

  11. MAG-EPA resolves lung inflammation in an allergic model of asthma.

    PubMed

    Morin, C; Fortin, S; Cantin, A M; Rousseau, É

    2013-09-01

    Asthma is a chronic disease characterized by airways hyperresponsiveness, inflammation and airways remodelling involving reversible bronchial obstruction. Omega-3 fatty acids and their derivatives are known to reduce inflammation in several tissues including lung. The effects of eicosapentaenoic acid monoacylglyceride (MAG-EPA), a newly synthesized EPA derivative, were determined on the resolution of lung inflammation and airway hyperresponsiveness in an in vivo model of allergic asthma. Ovalbumin (OVA)-sensitized guinea-pigs were treated or not with MAG-EPA administered per os. Isometric tension measurements, histological analyses, homogenate preparation for Western blot experiments or total RNA extraction for RT-PCR were performed to assess the effect of MAG-EPA treatments. Mechanical tension measurements revealed that oral MAG-EPA treatments reduced methacholine (MCh)-induced bronchial hyperresponsiveness in OVA-sensitized guinea-pigs. Moreover, MAG-EPA treatments also decreased Ca(2+) hypersensitivity of bronchial smooth muscle. Histological analyses and leucocyte counts in bronchoalveolar lavages revealed that oral MAG-EPA treatments led to less inflammatory cell recruitment in the lung of OVA-sensitized guinea-pigs when compared with lungs from control animals. Results also revealed a reduction in mucin production and MUC5AC expression level in OVA-sensitized animals treated with MAG-EPA. Following MAG-EPA treatments, the transcript levels of pro-inflammatory markers such as IL-5, eotaxin, IL-13 and IL-4 were markedly reduced. Moreover, per os MAG-EPA administrations reduced COX2 over-expression in OVA-sensitized animals. We demonstrate that MAG-EPA reduces airway hyperresponsiveness and lung inflammation in OVA-sensitized animals, a finding consistent with a decrease in IL-4, IL-5, IL-13, COX-2 and MUC5AC expression levels in the lung. The present data suggest that MAG-EPA represents a new potential therapeutic strategy for resolving inflammation in allergic

  12. 14 CFR 25.1163 - Powerplant accessories.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... the engine oil system and the accessory system. (b) Electrical equipment subject to arcing or sparking... to prevent rotation without interfering with the continued operation of the engine. [Doc. No. 5066... Powerplant accessories. (a) Each engine mounted accessory must— (1) Be approved for mounting on the engine...

  13. 14 CFR 25.1163 - Powerplant accessories.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... the engine oil system and the accessory system. (b) Electrical equipment subject to arcing or sparking... to prevent rotation without interfering with the continued operation of the engine. [Doc. No. 5066... Powerplant accessories. (a) Each engine mounted accessory must— (1) Be approved for mounting on the engine...

  14. 14 CFR 25.1163 - Powerplant accessories.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the engine oil system and the accessory system. (b) Electrical equipment subject to arcing or sparking... to prevent rotation without interfering with the continued operation of the engine. [Doc. No. 5066... Powerplant accessories. (a) Each engine mounted accessory must— (1) Be approved for mounting on the engine...

  15. 14 CFR 25.1163 - Powerplant accessories.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the engine oil system and the accessory system. (b) Electrical equipment subject to arcing or sparking... to prevent rotation without interfering with the continued operation of the engine. [Doc. No. 5066... Powerplant accessories. (a) Each engine mounted accessory must— (1) Be approved for mounting on the engine...

  16. MAG4 Versus Alternative Techniques for Forecasting Active-Region Flare Productivity

    NASA Technical Reports Server (NTRS)

    Falconer, David A.; Moore, Ronald L.; Barghouty, Abdulnasser F.; Khazanov, Igor

    2014-01-01

    MAG4 is a technique of forecasting an active region's rate of production of major flares in the coming few days from a free-magnetic-energy proxy. We present a statistical method of measuring the difference in performance between MAG4 and comparable alternative techniques that forecast an active region's major-flare productivity from alternative observed aspects of the active region. We demonstrate the method by measuring the difference in performance between the "Present MAG4" technique and each of three alternative techniques, called "McIntosh Active-Region Class," "Total Magnetic Flux," and "Next MAG4." We do this by using (1) the MAG4 database of magnetograms and major-flare histories of sunspot active regions, (2) the NOAA table of the major-flare productivity of each of 60 McIntosh active-region classes of sunspot active regions, and (3) five technique-performance metrics (Heidke Skill Score, True Skill Score, Percent Correct, Probability of Detection, and False Alarm Rate) evaluated from 2000 random two-by-two contingency tables obtained from the databases. We find that (1) Present MAG4 far outperforms both McIntosh Active-Region Class and Total Magnetic Flux, (2) Next MAG4 significantly outperforms Present MAG4, (3) the performance of Next MAG4 is insensitive to the forward and backward temporal windows used, in the range of one to a few days, and (4) forecasting from the free-energy proxy in combination with either any broad category of McIntosh active-region classes or any Mount Wilson active-region class gives no significant performance improvement over forecasting from the free-energy proxy alone (Present MAG4).

  17. Pleomorphic adenoma of the accessory parotid gland: case report and reappraisal of intraoral extracapsular dissection for management.

    PubMed

    Tsegga, Tibebu M; Britt, Jennifer D; Ellwanger, Aragon R

    2015-03-01

    Pleomorphic adenoma is the most common tumor of the major and minor salivary glands. Rarely is it found evolving from an ectopic location of major salivary glandular tissue in the mid cheek. A healthy 56-year-old woman presented to our institution with a 20-year duration of a slowly growing right cheek soft tissue mass that was causing facial asymmetry. No significant functional or neurosensory dysfunction was appreciated. Radiologic examination showed a heterogeneous, hyperintense, well-delineated mass within the region of the right buccal fat pad. Fine-needle aspiration biopsy showed benign salivary gland elements consistent with pleomorphic adenoma. The decision was made to perform intraoral extracapsular dissection for removal. Discussion of the clinical assessment and magnetic resonance imaging evaluation with an emphasis on intraoral extracapsular dissection for definitive surgical therapy of longstanding benign salivary gland tumors is emphasized. Published by Elsevier Inc.

  18. Classification of parotidectomies: a proposal of the European Salivary Gland Society.

    PubMed

    Quer, M; Guntinas-Lichius, O; Marchal, F; Vander Poorten, V; Chevalier, D; León, X; Eisele, D; Dulguerov, P

    2016-10-01

    The objective of this study is to provide a comprehensive classification system for parotidectomy operations. Data sources include Medline publications, author's experience, and consensus round table at the Third European Salivary Gland Society (ESGS) Meeting. The Medline database was searched with the term "parotidectomy" and "definition". The various definitions of parotidectomy procedures and parotid gland subdivisions extracted. Previous classification systems re-examined and a new classification proposed by a consensus. The ESGS proposes to subdivide the parotid parenchyma in five levels: I (lateral superior), II (lateral inferior), III (deep inferior), IV (deep superior), V (accessory). A new classification is proposed where the type of resection is divided into formal parotidectomy with facial nerve dissection and extracapsular dissection. Parotidectomies are further classified according to the levels removed, as well as the extra-parotid structures ablated. A new classification of parotidectomy procedures is proposed.

  19. 21 CFR 878.4960 - Operating tables and accessories and operating chairs and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Operating tables and accessories and operating chairs and accessories. 878.4960 Section 878.4960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical...

  20. 21 CFR 878.4960 - Operating tables and accessories and operating chairs and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Operating tables and accessories and operating chairs and accessories. 878.4960 Section 878.4960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical...

  1. 21 CFR 878.4960 - Operating tables and accessories and operating chairs and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Operating tables and accessories and operating chairs and accessories. 878.4960 Section 878.4960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical...

  2. 21 CFR 878.4960 - Operating tables and accessories and operating chairs and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Operating tables and accessories and operating chairs and accessories. 878.4960 Section 878.4960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical...

  3. 21 CFR 878.4960 - Operating tables and accessories and operating chairs and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Operating tables and accessories and operating chairs and accessories. 878.4960 Section 878.4960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical...

  4. Evaluation of Weldability for MAG and LASER with Galvannealed Steel.

    PubMed

    Kim, Jong-Hee; Bang, Han-Sur; Bang, Hee-Seon

    2018-03-01

    Lower-arm, one of the components in automotive suspension module, has been fabricated by MAG welding in general which is lap jointed with 2 mm thick galvannealed steel sheet (SGAPH440). This welding process produces some problems such as significantly much spatters and weld defects of porosity in welded joint, which degrades productivity and weldability. Therefore, in order to solve these problems, this study has been tried to apply two types of solid wires with different chemical composition rate of Si and Mn, in MAG welding process. Moreover, the laser welding process has been adopted to fabricate the low-arm and compared with those of MAG welding, in terms of mechanical and metallurgical characteristics. It was observed that in MAG welded joints, much more spatters were occurred in using solid wire with higher Si and Mn contains. The maximum tensile-shear strength in laser welded joints was approximately 16.7 kN, which was almost equal to that of in MAG welded joints. The microstructure showed ferrite and martensite in weld metal in MAG and laser welded joints indicating no significantly grain size change.

  5. 14 CFR 29.1163 - Powerplant accessories.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Powerplant accessories. (a) Each engine mounted accessory must— (1) Be approved for mounting on the engine involved; (2) Use the provisions on the engine for mounting; and (3) Be sealed in such a way as to prevent contamination of the engine oil system and the accessory system. (b) Electrical equipment subject to arcing or...

  6. 14 CFR 29.1163 - Powerplant accessories.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Powerplant accessories. (a) Each engine mounted accessory must— (1) Be approved for mounting on the engine involved; (2) Use the provisions on the engine for mounting; and (3) Be sealed in such a way as to prevent contamination of the engine oil system and the accessory system. (b) Electrical equipment subject to arcing or...

  7. 14 CFR 29.1163 - Powerplant accessories.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Powerplant accessories. (a) Each engine mounted accessory must— (1) Be approved for mounting on the engine involved; (2) Use the provisions on the engine for mounting; and (3) Be sealed in such a way as to prevent contamination of the engine oil system and the accessory system. (b) Electrical equipment subject to arcing or...

  8. 14 CFR 29.1163 - Powerplant accessories.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Powerplant accessories. (a) Each engine mounted accessory must— (1) Be approved for mounting on the engine involved; (2) Use the provisions on the engine for mounting; and (3) Be sealed in such a way as to prevent contamination of the engine oil system and the accessory system. (b) Electrical equipment subject to arcing or...

  9. Histological changes in male accessory reproductive organs in rats exposed to cigarette smoke and the protective effect of honey supplementation.

    PubMed

    Mohamed, Mahaneem; Sulaiman, Siti Amrah; Jaafar, Hasnan

    2012-01-01

    The effect of cigarette smoke (CS) on histology of male accessory reproductive organs and the possible protective effect of honey supplementation in rats were investigated in this study. Rats received distilled water, honey, CS exposure or honey plus CS exposure. Honey (1.2 g/kg body weight/day) was administered by gavage and CS exposure (3 times per day) was done in a chamber for 13 weeks. CS exposure significantly increased relative weight of epididymis and ventral prostate. There were also significantly increased number of clear cells and epithelial height of cauda epididymis as well as severe interstitial oedema and decreased epithelial height of prostate gland. However, with the supplementation of honey, these histological changes were significantly reversed suggesting the protective effect of honey against the toxic effect of CS on male accessory reproductive organs in rats.

  10. MagLev Cobra: Test Facilities and Operational Experiments

    NASA Astrophysics Data System (ADS)

    Sotelo, G. G.; Dias, D. H. J. N.; de Oliveira, R. A. H.; Ferreira, A. C.; De Andrade, R., Jr.; Stephan, R. M.

    2014-05-01

    The superconducting MagLev technology for transportation systems is becoming mature due to the research and developing effort of recent years. The Brazilian project, named MagLev-Cobra, started in 1998. It has the goal of developing a superconducting levitation vehicle for urban areas. The adopted levitation technology is based on the diamagnetic and the flux pinning properties of YBa2Cu3O7-δ (YBCO) bulk blocks in the interaction with Nd-Fe-B permanent magnets. A laboratory test facility with permanent magnet guideway, linear induction motor and one vehicle module is been built to investigate its operation. The MagLev-Cobra project state of the art is presented in the present paper, describing some construction details of the new test line with 200 m.

  11. Neurophysiological and clinical responses to rituximab in patients with anti-MAG polyneuropathy.

    PubMed

    Zara, Gabriella; Zambello, Renato; Ermani, M

    2011-12-01

    Rituximab treatment has shown clinical improvement in anti-myelin associated glycoprotein (MAG) polyneuropathy. We analyzed scores of clinical scales and the most sensitive electrophysiological parameters before and after immunomodulating treatment with rituximab in a group of patients affected by anti-MAG demyelinating polyneuropathy. Clinical scores, the percentage of CD20 B-lymphocytes, anti-MAG antibody titers and electrophysiological data in 7 patients with anti-MAG polyneuropathy were analyzed. The patients were examined before a cycle with rituximab, 6, 12 and 24 months after the end of the treatment. Two patients were treated with rituximab additional cycles and re-evaluated 48 months after the first treatment. There were no evident correlation between anti-MAG serum antibody titers or clinical scales and electrodiagnostic data. Significant decrease in the proportion of CD20 B-lymphocytes was observed. Significant anti-MAG antibodies titers reduction was detected after re-treatment. At follow-up, pinprik sensation and two point discrimination presented a significant improvement compared with the score before treatment. In our patients, rituximab did not improve any electrophysiological data. No correlation with anti-MAG serum antibodies course was found. With rituximab only pin sensibility improved. Rituximab re-treatment significantly reduces anti-MAG serum antibodies titers but improves only small fibers sensibility. Copyright © 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  12. Accessory Muscles of the Extremities.

    PubMed

    Vanhoenacker, Filip M; Desimpel, Julie; Mespreuve, Marc; Tagliafico, Alberto

    2018-07-01

    Accessory muscles and variations are not uncommon at the upper and lower extremity. They are often overlooked because they are asymptomatic and present as incidental findings on imaging. However, they may present as a soft tissue swelling, thereby mimicking soft tissue tumors. Other symptoms are attributed to impingement on neurovascular structures and to exercise-related pain. Thorough knowledge of the anatomy, systematic imaging analysis, and the awareness of it are the clues to correct identification. On ultrasound, accessory muscles have a similar echotexture as other muscles, whereas the signal intensity on magnetic resonance imaging (MRI) is similar to muscle. Because of the intrinsic contrast with the adjacent intermuscular fat, accessory muscles are best depicted on MRI without fat suppression. This article provides a short overview of the anatomy of most prevalent accessory muscles of the upper and lower limb and its potential pathogenic nature. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  13. 21 CFR 878.4350 - Cryosurgical unit and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... and accessories. (a) Identification—(1) Cryosurgical unit with a liquid nitrogen cooled cryoprobe and accessories. A cryosurgical unit with a liquid nitrogen cooled cryoprobe and accessories is a device intended...

  14. 75 FR 76962 - Application To Export Electric Energy; MAG Energy Solutions, Inc.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-10

    ... DEPARTMENT OF ENERGY [OE Docket No. EA-306-A] Application To Export Electric Energy; MAG Energy Solutions, Inc. AGENCY: Office of Electricity Delivery and Energy Reliability, DOE. ACTION: Notice of Application. SUMMARY: MAG Energy Solutions, Inc. (MAG E.S.) has applied to renew its authority to transmit...

  15. Evaluation of usefulness of fine-needle aspiration cytology in the diagnosis of tumours of the accessory parotid gland: a preliminary analysis of a case series in Japan.

    PubMed

    Iguchi, Hiroyoshi; Wada, Tadashi; Matsushita, Naoki; Oishi, Masahiro; Teranishi, Yuichi; Yamane, Hideo

    2014-07-01

    The accuracy and sensitivity of fine-needle aspiration cytology (FNAC) in this analysis were not satisfactory, and the false-negative rate seemed to be higher than for parotid tumours. The possibility of low-grade malignancy should be considered in the surgical treatment of accessory parotid gland (APG) tumours, even if the preoperative results of FNAC suggest that the tumour is benign. Little is known about the usefulness of FNAC in the preoperative evaluation of APG tumours, probably due to the paucity of APG tumour cases. We examined the usefulness of FNAC in the detection of malignant APG tumours. We conducted a retrospective analysis of 3 cases from our hospital, along with 18 previously reported Japanese cases. We compared the preoperative FNAC results with postoperative histopathological diagnoses of APG tumours and evaluated the accuracy, sensitivity, specificity and false-negative rates of FNAC in detecting malignant APG tumours. There were four false-negative cases (19.0%), three of mucoepidermoid carcinomas and one of malignant lymphoma. One false-positive result was noted in the case of a myoepithelioma, which was cytologically diagnosed as suspected adenoid cystic carcinoma. The accuracy, sensitivity and specificity of FNAC in detecting malignant tumours were 76.2%, 60.0% and 90.9%, respectively.

  16. 21 CFR 878.4950 - Manual operating table and accessories and manual operating chair and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Manual operating table and accessories and manual operating chair and accessories. 878.4950 Section 878.4950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES...

  17. 21 CFR 878.4950 - Manual operating table and accessories and manual operating chair and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Manual operating table and accessories and manual operating chair and accessories. 878.4950 Section 878.4950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES...

  18. 21 CFR 878.4950 - Manual operating table and accessories and manual operating chair and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Manual operating table and accessories and manual operating chair and accessories. 878.4950 Section 878.4950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES...

  19. 21 CFR 878.4950 - Manual operating table and accessories and manual operating chair and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Manual operating table and accessories and manual operating chair and accessories. 878.4950 Section 878.4950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES...

  20. 21 CFR 878.4950 - Manual operating table and accessories and manual operating chair and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual operating table and accessories and manual operating chair and accessories. 878.4950 Section 878.4950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES...

  1. 14 CFR 25.1163 - Powerplant accessories.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Powerplant accessories. (a) Each engine mounted accessory must— (1) Be approved for mounting on the engine involved; (2) Use the provisions on the engine for mounting; and (3) Be sealed to prevent contamination of...

  2. MagPy: A Python toolbox for controlling Magstim transcranial magnetic stimulators.

    PubMed

    McNair, Nicolas A

    2017-01-30

    To date, transcranial magnetic stimulation (TMS) studies manipulating stimulation parameters have largely used blocked paradigms. However, altering these parameters on a trial-by-trial basis in Magstim stimulators is complicated by the need to send regular (1Hz) commands to the stimulator. Additionally, effecting such control interferes with the ability to send TMS pulses or simultaneously present stimuli with high-temporal precision. This manuscript presents the MagPy toolbox, a Python software package that provides full control over Magstim stimulators via the serial port. It is able to maintain this control with no impact on concurrent processing, such as stimulus delivery. In addition, a specially-designed "QuickFire" serial cable is specified that allows MagPy to trigger TMS pulses with very low-latency. In a series of experimental simulations, MagPy was able to maintain uninterrupted remote control over the connected Magstim stimulator across all testing sessions. In addition, having MagPy enabled had no effect on stimulus timing - all stimuli were presented for precisely the duration specified. Finally, using the QuickFire cable, MagPy was able to elicit TMS pulses with sub-millisecond latencies. The MagPy toolbox allows for experiments that require manipulating stimulation parameters from trial to trial. Furthermore, it can achieve this in contexts that require tight control over timing, such as those seeking to combine TMS with fMRI or EEG. Together, the MagPy toolbox and QuickFire serial cable provide an effective means for controlling Magstim stimulators during experiments while ensuring high-precision timing. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. 14 CFR 29.1163 - Powerplant accessories.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Powerplant accessories. (a) Each engine mounted accessory must— (1) Be approved for mounting on the engine involved; (2) Use the provisions on the engine for mounting; and (3) Be sealed in such a way as to prevent...

  4. 14 CFR 27.1163 - Powerplant accessories.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Powerplant accessories. (a) Each engine-mounted accessory must— (1) Be approved for mounting on the engine involved; (2) Use the provisions on the engine for mounting; and (3) Be sealed in such a way as to prevent...

  5. 21 CFR 884.6120 - Assisted reproduction accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... II (special controls) (design specifications, labeling requirements, and clinical testing). ... Assisted reproduction accessories. (a) Identification. Assisted reproduction accessories are a group of...

  6. 21 CFR 884.6120 - Assisted reproduction accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... II (special controls) (design specifications, labeling requirements, and clinical testing). ... Assisted reproduction accessories. (a) Identification. Assisted reproduction accessories are a group of...

  7. 21 CFR 884.6120 - Assisted reproduction accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... II (special controls) (design specifications, labeling requirements, and clinical testing). ... Assisted reproduction accessories. (a) Identification. Assisted reproduction accessories are a group of...

  8. 21 CFR 872.3980 - Endosseous dental implant accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices intended...

  9. 21 CFR 872.3980 - Endosseous dental implant accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices intended...

  10. 21 CFR 872.3980 - Endosseous dental implant accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices intended...

  11. 21 CFR 872.3980 - Endosseous dental implant accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices intended...

  12. 21 CFR 872.3980 - Endosseous dental implant accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices intended...

  13. MagLIF scaling on Z and future machines

    NASA Astrophysics Data System (ADS)

    Slutz, Stephen; Stygar, William; Gomez, Matthew; Campbell, Edward; Peterson, Kyle; Sefkow, Adam; Sinars, Daniel; Vesey, Roger

    2015-11-01

    The MagLIF (Magnetized Liner Inertial Fusion) concept [S.A. Slutz et al Phys. Plasmas 17, 056303, 2010] has demonstrated [M.R. Gomez et al., PRL 113, 155003, 2014] fusion-relevant plasma conditions on the Z machine. We present 2D numerical simulations of the scaling of MagLIF on Z indicating that deuterium/tritium (DT) fusion yields greater than 100 kJ could be possible on Z when operated at a peak current of 25 MA. Much higher yields are predicted for MagLIF driven with larger peak currents. Two high performance pulsed-power machines (Z300 and Z800) have been designed based on Linear Transformer Driver (LTD) technology. The Z300 design would provide approximately 48 MA to a MagLIF load, while Z800 would provide about 66 MA. We used a parameterized Thevenin equivalent circuit to drive a series of 1D and 2D numerical simulations with currents between and beyond these two designs. Our simulations indicate that 5-10 MJ yields may be possible with Z300, while yields of about 1 GJ may be possible with Z800. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  14. 21 CFR 876.5250 - Urine collector and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Urine collector and accessories. 876.5250 Section... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5250 Urine collector and accessories. (a) Identification. A urine collector and accessories is a device intended to collect...

  15. 21 CFR 876.5250 - Urine collector and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Urine collector and accessories. 876.5250 Section... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5250 Urine collector and accessories. (a) Identification. A urine collector and accessories is a device intended to collect...

  16. 21 CFR 876.5250 - Urine collector and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Urine collector and accessories. 876.5250 Section... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5250 Urine collector and accessories. (a) Identification. A urine collector and accessories is a device intended to collect...

  17. 21 CFR 876.5250 - Urine collector and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Urine collector and accessories. 876.5250 Section... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5250 Urine collector and accessories. (a) Identification. A urine collector and accessories is a device intended to collect...

  18. 21 CFR 876.5250 - Urine collector and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Urine collector and accessories. 876.5250 Section... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5250 Urine collector and accessories. (a) Identification. A urine collector and accessories is a device intended to collect...

  19. 21 CFR 868.5860 - Pressure tubing and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pressure tubing and accessories. 868.5860 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5860 Pressure tubing and accessories. (a) Identification. Pressure tubing and accessories are flexible or rigid devices intended to...

  20. Illuminating the Depths of the MagIC (Magnetics Information Consortium) Database

    NASA Astrophysics Data System (ADS)

    Koppers, A. A. P.; Minnett, R.; Jarboe, N.; Jonestrask, L.; Tauxe, L.; Constable, C.

    2015-12-01

    The Magnetics Information Consortium (http://earthref.org/MagIC/) is a grass-roots cyberinfrastructure effort envisioned by the paleo-, geo-, and rock magnetic scientific community. Its mission is to archive their wealth of peer-reviewed raw data and interpretations from magnetics studies on natural and synthetic samples. Many of these valuable data are legacy datasets that were never published in their entirety, some resided in other databases that are no longer maintained, and others were never digitized from the field notebooks and lab work. Due to the volume of data collected, most studies, modern and legacy, only publish the interpreted results and, occasionally, a subset of the raw data. MagIC is making an extraordinary effort to archive these data in a single data model, including the raw instrument measurements if possible. This facilitates the reproducibility of the interpretations, the re-interpretation of the raw data as the community introduces new techniques, and the compilation of heterogeneous datasets that are otherwise distributed across multiple formats and physical locations. MagIC has developed tools to assist the scientific community in many stages of their workflow. Contributors easily share studies (in a private mode if so desired) in the MagIC Database with colleagues and reviewers prior to publication, publish the data online after the study is peer reviewed, and visualize their data in the context of the rest of the contributions to the MagIC Database. From organizing their data in the MagIC Data Model with an online editable spreadsheet, to validating the integrity of the dataset with automated plots and statistics, MagIC is continually lowering the barriers to transforming dark data into transparent and reproducible datasets. Additionally, this web application generalizes to other databases in MagIC's umbrella website (EarthRef.org) so that the Geochemical Earth Reference Model (http://earthref.org/GERM/) portal, Seamount Biogeosciences

  1. Disposable MagLev centrifugal blood pump utilizing a cone-shaped impeller.

    PubMed

    Hijikata, Wataru; Sobajima, Hideo; Shinshi, Tadahiko; Nagamine, Yasuyuki; Wada, Suguru; Takatani, Setsuo; Shimokohbe, Akira

    2010-08-01

    To enhance the durability and reduce the blood trauma of a conventional blood pump with a cone-shaped impeller, a magnetically levitated (MagLev) technology has been applied to the BioPump BPX-80 (Medtronic Biomedicus, Inc., Minneapolis, MN, USA), whose impeller is supported by a mechanical bearing. The MagLev BioPump (MagLev BP), which we have developed, has a cone-shaped impeller, the same as that used in the BPX-80. The suspension and driving system, which is comprised of two degrees of freedom, radial-controlled magnetic bearing, and a simply structured magnetic coupling, eliminates any physical contact between the impeller and the housing. To reduce both oscillation of the impeller and current in the coils, the magnetic bearing system utilizes repetitive and zero-power compensators. In this article, we present the design of the MagLev mechanism, measure the levitational accuracy of the impeller and pressure-flow curves (head-quantity [HQ] characteristics), and describe in vitro experiments designed to measure hemolysis. For the flow-induced hemolysis of the initial design to be reduced, the blood damage index was estimated by using computational fluid dynamics (CFD) analysis. Stable rotation of the impeller in a prototype MagLev BP from 0 to 2750 rpm was obtained, yielding a flow rate of 5 L/min against a head pressure in excess of 250 mm Hg. Because the impeller of the prototype MagLev BP is levitated without contact, the normalized index of hemolysis was 10% less than the equivalent value with the BPX-80. The results of the CFD analysis showed that the shape of the outlet and the width of the fluid clearances have a large effect on blood damage. The prototype MagLev BP satisfied the required HQ characteristics (5 L/min, 250 mm Hg) for extracorporeal circulation support with stable levitation of the impeller and showed an acceptable level of hemolysis. The simulation results of the CFD analysis indicated the possibility of further reducing the blood damage of

  2. Three Accessories for a Rotating Platform.

    ERIC Educational Resources Information Center

    Riley, James A.; Fryer, Oscar G.

    1980-01-01

    Describes three accessories developed to be used in conjunction with the rotating platform or turntable. Three demonstrations using these accessories are included. These demonstrations are: (a) conservation of angular momentum; (b) gravity-defying goblets; and (c) direct measurement of centripetal force. (HM)

  3. MagR Alone Is Insufficient to Confer Cellular Calcium Responses to Magnetic Stimulation

    PubMed Central

    Pang, Keliang; You, He; Chen, Yanbo; Chu, Pengcheng; Hu, Meiqin; Shen, Jianying; Guo, Wei; Xie, Can; Lu, Bai

    2017-01-01

    Magnetic manipulation of cell activity offers advantages over optical manipulation but an ideal tool remains elusive. The MagR protein was found through its interaction with cryptochrome (Cry) and the protein in solution appeared to respond to magnetic stimulation (MS). After we initiated an investigation on the specific role of MagR in cellular response to MS, a subsequent study claimed that MagR expression alone could achieve cellular activation by MS. Here we report that despite systematically testing different ways of measuring intracellular calcium and different MS protocols, it was not possible to detect any cellular or neuronal responses to MS in MagR-expressing HEK cells or primary neurons from the dorsal root ganglion and the hippocampus. By contrast, in neurons co-expressing MagR and channelrhodopin, optical but not MS increased calcium influx in hippocampal neurons. Our results indicate that MagR alone is not sufficient to confer cellular magnetic responses. PMID:28360843

  4. 14 CFR 25.1192 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Engine accessory section diaphragm. 25.1192....1192 Engine accessory section diaphragm. For reciprocating engines, the engine power section and all portions of the exhaust system must be isolated from the engine accessory compartment by a diaphragm that...

  5. 14 CFR 25.1192 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Engine accessory section diaphragm. 25.1192....1192 Engine accessory section diaphragm. For reciprocating engines, the engine power section and all portions of the exhaust system must be isolated from the engine accessory compartment by a diaphragm that...

  6. 14 CFR 25.1192 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Engine accessory section diaphragm. 25.1192....1192 Engine accessory section diaphragm. For reciprocating engines, the engine power section and all portions of the exhaust system must be isolated from the engine accessory compartment by a diaphragm that...

  7. Neurologic syndrome associated with homozygous mutation at MAG sialic acid binding site.

    PubMed

    Roda, Ricardo H; FitzGibbon, Edmond J; Boucekkine, Houda; Schindler, Alice B; Blackstone, Craig

    2016-08-01

    The MAG gene encodes myelin-associated glycoprotein (MAG), an abundant protein involved in axon-glial interactions and myelination during nerve regeneration. Several members of a consanguineous family with a clinical syndrome reminiscent of Pelizaeus-Merzbacher disease and demyelinating leukodystrophy on brain MRI were recently found to harbor a homozygous missense p.Ser133Arg MAG mutation. Here, we report two brothers from a nonconsanguineous family afflicted with progressive cognitive impairment, neuropathy, ataxia, nystagmus, and gait disorder. Exome sequencing revealed the homozygous missense mutation p.Arg118His in MAG. This Arg118 residue in immunoglobulin domain 1 is critical for sialic acid binding, providing a compelling mechanistic basis for disease pathogenesis.

  8. 21 CFR 872.4200 - Dental handpiece and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental handpiece and accessories. 872.4200 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4200 Dental handpiece and accessories. (a) Identification. A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven...

  9. 21 CFR 872.4200 - Dental handpiece and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental handpiece and accessories. 872.4200 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4200 Dental handpiece and accessories. (a) Identification. A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven...

  10. 21 CFR 872.4200 - Dental handpiece and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental handpiece and accessories. 872.4200 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4200 Dental handpiece and accessories. (a) Identification. A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven...

  11. 21 CFR 872.4200 - Dental handpiece and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental handpiece and accessories. 872.4200 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4200 Dental handpiece and accessories. (a) Identification. A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven...

  12. 21 CFR 872.4200 - Dental handpiece and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental handpiece and accessories. 872.4200 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4200 Dental handpiece and accessories. (a) Identification. A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven...

  13. 21 CFR 876.5900 - Ostomy pouch and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ostomy pouch and accessories. 876.5900 Section 876...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5900 Ostomy pouch and accessories. (a) Identification. An ostomy pouch and accessories is a device that consists of a bag that is...

  14. 21 CFR 872.6250 - Dental chair and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental chair and accessories. 872.6250 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6250 Dental chair and accessories. (a) Identification. A dental chair and accessories is a device, usually AC-powered, in which a patient sits. The...

  15. 21 CFR 872.6250 - Dental chair and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental chair and accessories. 872.6250 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6250 Dental chair and accessories. (a) Identification. A dental chair and accessories is a device, usually AC-powered, in which a patient sits. The...

  16. 21 CFR 872.6250 - Dental chair and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental chair and accessories. 872.6250 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6250 Dental chair and accessories. (a) Identification. A dental chair and accessories is a device, usually AC-powered, in which a patient sits. The...

  17. 21 CFR 872.6250 - Dental chair and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental chair and accessories. 872.6250 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6250 Dental chair and accessories. (a) Identification. A dental chair and accessories is a device, usually AC-powered, in which a patient sits. The...

  18. 21 CFR 872.6250 - Dental chair and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental chair and accessories. 872.6250 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6250 Dental chair and accessories. (a) Identification. A dental chair and accessories is a device, usually AC-powered, in which a patient sits. The...

  19. Accessories make the outfit: Accessory Chromosomes and other dispensable DNA regions in plant-pathogenic Fungi.

    PubMed

    Bertazzoni, Stefania; Williams, Angela; Jones, Darcy A B; Syme, Robert A; Tan, Kar-Chun; Hane, James Kyawzwar

    2018-04-17

    Fungal pathogen genomes can often be divided into core and accessory regions. Accessory regions may be comprised of either accessory regions (ARs) within core chromosomes (CCs), or wholly-dispensable (accessory) chromosomes (ACs). Fungal ACs and ARs typically accumulate mutations and structural rearrangements more rapidly over time than CCs, and many harbour genes relevant to host-pathogen interactions. These regions are of particular interest in plant pathology and include host-specific virulence factors and secondary metabolite synthesis gene clusters. This review outlines known ACs and ARs in fungal genomes, methods used for their detection, their common properties that differentiate them from the core genome, and what is currently known of their various roles in pathogenicity. Reports on the evolutionary processes generating and shaping AC/AR compartments are discussed, including repeat induced point mutation (RIP) and breakage-fusion-bridge (BFB) cycles. Previously ACs have been studied extensively within key genera including Fusarium, Zymoseptoria and Alternaria, but are growing in their frequency of observation and perceived importance across a wider range of fungal species. Recent advances in sequencing technologies permit affordable genome assembly and re-sequencing of populations that will facilitate further discovery and routine screening of ACs.

  20. Proteomic Profiling of the Pituitary Gland in Studies of Psychiatric Disorders.

    PubMed

    Krishnamurthy, Divya; Rahmoune, Hassan; Guest, Paul C

    2017-01-01

    Psychiatric disorders have been associated with perturbations of the hypothalamic-pituitary-adrenal axis. Therefore, proteomic studies of the pituitary gland have the potential to provide new insights into the underlying pathways affected in these conditions as well as identify new biomarkers or targets for use in developing improved medications. This chapter describes a protocol for preparation of pituitary protein extracts followed by characterization of the pituitary proteome by label-free liquid chromatography-tandem mass spectrometry in expression mode (LC-MS E ). The main focus was on establishing a method for identifying the major pituitary hormones and accessory proteins as many of these have already been implicated in psychiatric diseases.

  1. The pathology of dry eye: the interaction between the ocular surface and lacrimal glands.

    PubMed

    Stern, M E; Beuerman, R W; Fox, R I; Gao, J; Mircheff, A K; Pflugfelder, S C

    1998-11-01

    Most dry-eye symptoms result from an abnormal, nonlubricative ocular surface that increases shear forces under the eyelids and diminishes the ability of the ocular surface to respond to environmental challenges. This ocular-surface dysfunction may result from immunocompromise due to systemic autoimmune disease or may occur locally from a decrease in systemic androgen support to the lacrimal gland as seen in aging, most frequently in the menopausal female. Components of the ocular surface (cornea, conjunctiva, accessory lacrimal glands, and meibomian glands), the main lacrimal gland, and interconnecting innervation act as a functional unit. When one portion is compromised, normal lacrimal support of the ocular surface is impaired. Resulting immune-based inflammation can lead to lacrimal gland and neural dysfunction. This progression yields the OS symptoms associated with dry eye. Restoration of lacrimal function involves resolution of lymphocytic activation and inflammation. This has been demonstrated in the MRL/lpr mouse using systemic androgens or cyclosporine and in the dry-eye dog using topical cyclosporine. The efficacy of cyclosporine may be due to its immunomodulatory and antiinflammatory (phosphatase inhibitory capability) functions on the ocular surface, resulting in a normalization of nerve traffic. Although the etiologies of dry eye are varied, common to all ocular-surface disease is an underlying cytokine/receptor-mediated inflammatory process. By treating this process, it may be possible to normalize the ocular surface/lacrimal neural reflex and facilitate ocular surface healing.

  2. 21 CFR 890.5925 - Traction accessory.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Traction accessory. 890.5925 Section 890.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5925 Traction accessory. (a...

  3. 21 CFR 890.5925 - Traction accessory.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Traction accessory. 890.5925 Section 890.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5925 Traction accessory. (a...

  4. 21 CFR 890.5925 - Traction accessory.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Traction accessory. 890.5925 Section 890.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5925 Traction accessory. (a...

  5. 21 CFR 890.5925 - Traction accessory.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Traction accessory. 890.5925 Section 890.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5925 Traction accessory. (a...

  6. 21 CFR 890.5925 - Traction accessory.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Traction accessory. 890.5925 Section 890.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5925 Traction accessory. (a...

  7. Anti-MAG antibodies in 202 patients: clinicopathological and therapeutic features.

    PubMed

    Svahn, Juliette; Petiot, Philippe; Antoine, Jean-Christophe; Vial, Christophe; Delmont, Emilien; Viala, Karine; Steck, Andreas J; Magot, Armelle; Cauquil, Cecile; Zarea, Aline; Echaniz-Laguna, Andoni; Iancu Ferfoglia, Ruxandra; Gueguen, Antoine; Magy, Laurent; Léger, Jean-Marc; Kuntzer, Thierry; Ferraud, Karine; Lacour, Arnaud; Camdessanché, Jean-Philippe

    2018-05-01

    To assess the clinicopathological and therapeutic features of patients with low (≥1000 to <10 000 Bühlmann Titre Units) (BTU), medium (10 000-70 000) or high (≥70 000) anti-myelin-associated glycoprotein (anti-MAG) antibody titres. We retrospectively and prospectively analysed standardised report forms and medical records of 202 patients from 14 neuromuscular centres. Mean age at onset and mean time between symptom onset to last follow-up were respectively 62.6 years (25-91.4) and 8.4 years (0.3-33.3). Anti-MAG antibody titres at diagnosis were low, medium or high in 11%, 51% and 38% of patients. Patients presented with monoclonal gammopathy of undetermined significance in 68% of cases. About 17% of patients presented with 'atypical' clinical phenotype independently of anti-MAG titres, including acute or chronic sensorimotor polyradiculoneuropathies (12.4%), and asymmetric or multifocal neuropathy (3%). At the most severe disease stage, 22.4% of patients were significantly disabled. Seventy-eight per cent of patients received immunotherapies. Transient clinical worsening was observed in 12% of patients treated with rituximab (11/92). Stabilisation after rituximab treatment during the 7-12-month follow-up period was observed in 29% of patients. Clinical response to rituximab during the 6-month and/or 7-12-month follow-up period was observed in 31.5% of patients and correlated with anti-MAG titre ≥10 000 BTU. Our study highlights the extended clinical spectrum of patients with anti-MAG neuropathy, which appears unrelated to antibody titre. Besides, it may also suggest beneficial use of rituximab in the early phase of anti-MAG neuropathy. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Evaluation of Accessory Lacrimal Gland in Muller's Muscle Conjunctival Resection Specimens for Precursor Cell Markers and Biological Markers of Dry Eye Disease.

    PubMed

    Ali, Marwan; Shah, Dhara; Pasha, Zeeshan; Jassim, Sarmad H; Jassim Jaboori, Assraa; Setabutr, Pete; Aakalu, Vinay K

    2017-04-01

    The accessory lacrimal glands (ALGs) are an understudied component of the tear functional unit, even though they are important in the development of dry eye syndrome (DES). To advance our understanding of aging changes, regenerative potential, and histologic correlates to human characteristics, we investigated human ALG tissue from surgical samples to determine the presence or absence of progenitor cell markers and lacrimal epithelial markers and to correlate marker expression to relevant patient characteristics. ALG tissues obtained from Muller's muscle conjunctival resection (MMCR) specimens were created using tissue microarrays (TMAs). Immunofluorescence staining of MMCR sections was performed using primary antibodies specific to cell protein markers. Cell marker localization in TMAs was then assessed by two blinded observers using a standardized scoring system. Patient characteristics including age, race, and status of ocular surface health were then compared against expression of stem cell markers. Human ALG expressed a number of epithelial markers, and in particular, histatin-1 was well correlated with the expression of epithelial markers and was present in most acini. In addition, we noted the presence of precursor cell markers nestin, ABCG2, and CD90 in ALG tissue. There was a decrease in precursor cell marker expression with increasing age. Finally, we noted that a negative association was present between histatin-1 expression and DES. Thus, we report for the first time that human ALG tissues contain precursor marker-positive cells and that this marker expression may decrease with increasing age. Moreover, histatin-1 expression may be decreased in DES. Future studies will be performed to use these cell markers to isolate and culture lacrimal epithelial cells from heterogeneous tissues, determine the relevance of histatin-1 expression to DES, and isolate candidate precursor cells from ALG tissue.

  9. MagCloud: magazine self-publishing for the long tail

    NASA Astrophysics Data System (ADS)

    Koh, Kok-Wei; Chatow, Ehud

    2010-02-01

    In June of 2008, Hewlett-Packard Labs launched MagCloud, a print-on-demand web service for magazine selfpublishing. MagCloud enables anyone to publish their own magazine by simply uploading a PDF file to the site. There are no setup fees, minimum print runs, storage requirements or waste due to unsold magazines. Magazines are only printed when an order is placed, and are shipped directly to the end customer. In the course of building this web service, a number of technological challenges were encountered. In this paper, we will discuss these challenges and the methods used to overcome them. Perhaps the most important decision in enabling the successful launch of MagCloud was the choice to offer a single product. This simplified the PDF validation phase and streamlined the print fulfillment process such that orders can be printed, folded and trimmed in batches, rather than one-by-one. In a sense, MagCloud adopted the Ford Model T approach to manufacturing, where having just a single model with little or no options allows for efficiencies in the production line, enabling a lower product price and opening the market to a much larger customer base. This platform has resulted in a number of new niche publications - the long tail of publishing.

  10. 47 CFR 15.27 - Special accessories.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... information required by this section may be included in the manual in that alternative form, provided the user..., shall ensure that these special accessories are provided with the equipment. The instruction manual for... responsibility of the user to use the needed special accessories supplied with the equipment. In cases where the...

  11. THOR Fluxgate Magnetometer (MAG)

    NASA Astrophysics Data System (ADS)

    Nakamura, Rumi; Eastwood, Jonathan; Magnes, Werner; Valavanoglou, Aris; Carr, Christopher M.; O'Brien, Helen L.; Narita, Yasuhito; Delva, Magda; Chen, Christopher H. K.; Plaschke, Ferdinand; Soucek, Jan

    2016-04-01

    Turbulence Heating ObserveR (THOR) is the first mission ever flown in space dedicated to plasma turbulence. The goal of the Fluxgate Magnetometer (MAG) is to measure the DC to low frequency ambient magnetic field. The design of the magnetometer consists of two tri-axial sensors and the related magnetometer electronics; the electronics are hosted on printed circuit boards in the common electronics box of the fields and wave processor (FWP). A fully redundant two sensor system mounted on a common boom and the new miniaturized low noise design based on MMS and Solar Orbiter instruments enable accurate measurement throughout the region of interest for THOR science. The usage of the common electronics hosted by FWP guarantees to fulfill the required timing accuracy with other fields measurements. These improvements are important to obtain precise measurements of magnetic field, which is essential to estimate basic plasma parameters and correctly identify the spatial and temporal scales of the turbulence. Furthermore, THOR MAG provides high quality data with sufficient overlap with the Search Coil Magnetometer (SCM) in frequency space to obtain full coverage of the wave forms over all the frequencies necessary to obtain the full solar wind turbulence spectrum from MHD to kinetic range with sufficient accuracy.

  12. Anatomy and histology of the prostate and glands of Cowper in three species of neotropical bats.

    PubMed

    Miotti, María Daniela; Mollerach, Marcos I; Barquez, Ruben M

    2018-03-01

    The reproductive accessory glands (RAG) are essential components in reproduction because their secretion products ensure survival, viability, and sperm motility. The objective of this study was to characterize and compare the morphological and histological structure of the RAG in three species of bats of the genus Sturnira (S. erythromos, S. lilium, and S. oporaphilum). The RAG complex comprise a compact gland (prostate), which surrounds the urethra, and a pair of Glands of Cowper at the base of penis. Anatomical and histologically, the prostate are differentiated in two regions, ventral and dorsal. The dorsal region has tubuloalveolar glands with secretions fine granular or accumulations of a gel-like substance with bubbles and the ventral region, has alveolar glands with secretory cells form a single-layer of small cells. The seminal vesicles are absent. The prostatic morphology of the three species is similar to that of other studied Stenodermatinae and Desmodontinae, but differs from other subfamilies of Phyllostomidae (Carollinae, Glossophaginae, and Phyllostominae) as that of Molossidae and Vespertilionidae. The RAG complex has no annual variation in relation to functionality or size, but it is variable depending on age (subadults and adults). This agrees with the annual reproductive pattern described for these species in these latitudes, where adult males are reproductively active throughout the year. © 2017 Wiley Periodicals, Inc.

  13. IgM MGUS associated with anti-MAG neuropathy: a single institution experience.

    PubMed

    Talamo, Giampaolo; Mir, Muhammad A; Pandey, Manoj K; Sivik, Jeffrey K; Raheja, Divisha

    2015-06-01

    Anti-MAG neuropathy is a very rare form of acquired polyneuropathy associated with IgM monoclonal gammopathy of undetermined significance (MGUS). We conducted a retrospective review of 194 consecutive MGUS patients seen at the Penn State Hershey Cancer Institute. We identified six patients among 37 (16 %) with IgM MGUS with anti-MAG neuropathy. Interestingly, an additional patient had anti-MAG neuropathy without MGUS. Common clinical manifestations were numbness and paresthesias of the extremities and gait imbalance. All four patients treated with rituximab and none of the three untreated ones had a subjective improvement of their symptoms. We conclude that all patients with IgM MGUS and neuropathy should be screened for anti-MAG antibodies and, if positive, they should be offered treatment with rituximab.

  14. Fuel magnetization without external field coils (AutoMag)

    NASA Astrophysics Data System (ADS)

    Slutz, Stephen; Jennings, Christopher; Awe, Thomas; Shipley, Gabe; Lamppa, Derek; McBride, Ryan

    2016-10-01

    Magnetized Liner Inertial Fusion (MagLIF) has produced fusion-relevant plasma conditions on the Z accelerator where the fuel was magnetized using external field coils. We present a novel concept that does not need external field coils. This concept (AutoMag) magnetizes the fuel during the early part of the drive current by using a composite liner with helical conduction paths separated by insulating material. The drive is designed so the current rises slowly enough to avoid electrical breakdown of the insulators until a sufficiently strong magnetic field is established. Then the current rises more quickly, which causes the insulators to break down allowing the drive current to follow an axial path and implode the liner. Low inductance magnetically insulated power feeds can be used with AutoMag to increase the drive current without interfering with diagnostic access. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  15. Future Development of Endoscopic Accessories for Endoscopic Submucosal Dissection

    PubMed Central

    Jang, Jae-Young

    2017-01-01

    Endoscopic submucosal dissection (ESD) has recently been accepted as a standard treatment for patients with early gastric cancer (EGC), without lymph node metastases. Given the rise in the number of ESDs being performed, new endoscopic accessories are being developed and existing accessories modified to facilitate the execution of ESD and reduce complication rates. This paper examines the history underlying the development of these new endoscopic accessories and indicates future directions for the development of these accessories. PMID:28609819

  16. Global and local magnetic mapping using CrowdMag data

    NASA Astrophysics Data System (ADS)

    Saltus, R.; Nair, M. C.

    2016-12-01

    NOAA's National Centers for Environmental Information (NCEI), in partnership with the University of Colorado's CIRES develop magnetic field models to aid navigation, resource exploration and scientific research. We use observatories, satellites and ship/airborne surveys to map and model the Earth's magnetic field. However, the available measurements leave gaps in coverage, particularly for short-wavelength anomalies associated with man-made infrastructure ("urban noise"). In 2014, we started a project to address these gaps through the collection of vector magnetic data from digital magnetometers in smartphones. In October 2014, we released the "CrowdMag" Android and iOS apps for harvesting data from phones. Currently, the CrowdMag project has more than 10,000 enthusiastic users contributing more than 12 million magnetic data measurements from around the world. We present the first analysis results from the crowdsourced magnetic data. A global magnetic model derived solely from CrowdMag data is consistent to degree and order 4 with satellite-derived models such as World Magnetic Model. A unique contribution of CrowdMag project is the collection of ground level magnetic data in densely populated regions with an unprecedented spatial resolution. To demonstrate, we generated a magnetic map (by binning the data collected in 200x200m cells) of central Boulder, Colorado using 170,000 data points collected by about 60 devices over the duration October 2014- January 2016. The median value is consistent with the expected magnitude of the Earth's background magnetic field. The standard deviation of the CrowdMag total field (F) values is much higher than the expected natural (i.e., diurnal and geologic) magnetic field variation. However, the phone's magnetometer is sensitive enough to capture the larger magnitude magnetic signature from the urban magnetic sources. We discuss the potential reliability of crowdsourced magnetic maps and their applications to navigation and other

  17. "Lights on at the end of the party": are lads' mags mainstreaming dangerous sexism?

    PubMed

    Horvath, Miranda A H; Hegarty, Peter; Tyler, Suzannah; Mansfield, Sophie

    2012-11-01

    Research has suggested that some magazines targeted at young men - lads' mags - are normalizing extreme sexist views by presenting those views in a mainstream context. Consistent with this view, young men in Study 1 (n = 90) identified more with derogatory quotes about women drawn from recent lads' mags, and from interviews with convicted rapists, when those quotes were attributed to lads' mags, than when they were attributed to convicted rapists. In Study 2, 40 young women and men could not reliably judge the source of those same quotes. While these participants sometimes voiced the belief that the content of lads' mags was 'normal' while rapists' talk was 'extreme', they categorized quotes from both sources as derogatory with equal frequency. Jointly, the two studies show an overlap in the content of convicted rapists' talk and the contents of contemporary lads' mags, and suggest that the framing of such content within lads' mags may normalize it for young men. ©2011 The British Psychological Society.

  18. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...

  19. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...

  20. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...

  1. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...

  2. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...

  3. 21 CFR 872.4920 - Dental electrosurgical unit and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental electrosurgical unit and accessories. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4920 Dental electrosurgical unit and accessories. (a) Identification. A dental electrosurgical unit and accessories is an AC-powered...

  4. 21 CFR 872.4920 - Dental electrosurgical unit and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental electrosurgical unit and accessories. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4920 Dental electrosurgical unit and accessories. (a) Identification. A dental electrosurgical unit and accessories is an AC-powered...

  5. 21 CFR 872.4920 - Dental electrosurgical unit and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental electrosurgical unit and accessories. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4920 Dental electrosurgical unit and accessories. (a) Identification. A dental electrosurgical unit and accessories is an AC-powered...

  6. 21 CFR 872.4920 - Dental electrosurgical unit and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental electrosurgical unit and accessories. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4920 Dental electrosurgical unit and accessories. (a) Identification. A dental electrosurgical unit and accessories is an AC-powered...

  7. 21 CFR 872.4920 - Dental electrosurgical unit and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental electrosurgical unit and accessories. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4920 Dental electrosurgical unit and accessories. (a) Identification. A dental electrosurgical unit and accessories is an AC-powered...

  8. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...

  9. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...

  10. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...

  11. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...

  12. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...

  13. 21 CFR 872.6640 - Dental operative unit and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental operative unit and accessories. 872.6640... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6640 Dental operative unit and accessories. (a) Identification. A dental operative unit and accessories is an AC-powered device that is...

  14. 21 CFR 872.6640 - Dental operative unit and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental operative unit and accessories. 872.6640... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6640 Dental operative unit and accessories. (a) Identification. A dental operative unit and accessories is an AC-powered device that is...

  15. 21 CFR 872.6640 - Dental operative unit and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental operative unit and accessories. 872.6640... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6640 Dental operative unit and accessories. (a) Identification. A dental operative unit and accessories is an AC-powered device that is...

  16. 21 CFR 872.6640 - Dental operative unit and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental operative unit and accessories. 872.6640... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6640 Dental operative unit and accessories. (a) Identification. A dental operative unit and accessories is an AC-powered device that is...

  17. 21 CFR 872.6640 - Dental operative unit and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental operative unit and accessories. 872.6640... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6640 Dental operative unit and accessories. (a) Identification. A dental operative unit and accessories is an AC-powered device that is...

  18. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  19. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  20. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  1. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  2. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  3. [Excision of accessory navicular with reconstruction of posterior tibial tendon insertion on navicular for treatment of flatfoot related with accessory navicular].

    PubMed

    Cao, Honghui; Tang, Kanglai; Deng, Yinshuan; Tan, Xiaokang; Zhou, Binghua; Tao, Xu; Chen, Lei; Chen, Qianbo

    2012-06-01

    To analyze the excision of accessory navicular with reconstruction of posterior tibial tendon insertion on navicular for the treatment of flatfoot related with accessory navicular and to evaluate its effectiveness. Between May 2006 and June 2011, 33 patients (40 feet) with flatfoot related with accessory navicular were treated. There were 14 males (17 feet) and 19 females (23 feet) with an average age of 30.1 years (range, 16-56 years). All patients had bilateral accessory navicular; 26 had unilateral flatfoot and 7 had bilateral flatfeet. The disease duration ranged from 7 months to 9 years (median, 24 months). The American Orthopaedic Foot and Ankle Society (AOFAS) ankle-midfoot score was 47.9 +/- 7.3. The X-ray films showed type II accessory navicular, the arch height loss, and heel valgus in all patients. All of them received excision of accessory navicular and reconstruction of posterior tibial tendon insertion on navicular with anchor. All patients got primary wound healing without any complication. Thirty patients (36 feet) were followed up 6-54 months with an average of 23 months. All patients achieved complete pain relief at 6 months after surgery and had good appearance of the feet. The AOFAS ankle-midfoot score was 90.4 +/- 2.0 at last follow-up, showing significant difference when compared with preoperative score (t=29.73, P=0.00). X-ray films showed that no screw loosening or breakage was observed. There were significant differences in the arch height, calcaneus inclination angle, talocalcaneal angle, and talar-first metatarsal angle between pre-operation and last follow-up (P < 0.01). The excision of accessory navicular with reconstruction of posterior tibial tendon insertion on navicular is a good choice for the treatment of flatfoot related with accessory navicular, with correction of deformity, excellent effectiveness, and less complications.

  4. [Comparative ultrastructural study of parotid gland, lacrimal gland and pituitary gland between miniature pig and mouse].

    PubMed

    Yan, Xing; Hai, Bo; Sun, Yi-lin; Zhang, Chun-mei; Wang, Song-ling

    2009-02-01

    To study the ultrastructure of parotid glands, lacrimal glands and pituitary glands between miniature pig and mouse. Five adult miniature pigs and 5 mice were studied. Ultrastructure of their parotid glands, lacrimal glands, and pituitary glands was observed. The secretary granules in acinar cell of miniature pig parotid glands showed higher density and more aequalis than those of mice. The cell apparatus in acinar cell of mouse parotid glands were more plentiful than those of miniature pigs. The secretary granules on blood vessel wall were richer in parotid gland of miniature pigs compared with mouse parotid gland. Lacrimal gland had the similar ultrastructure to parotid gland in these two animals. Many blood vessel antrum were found in pituitary glands of these two animals. Compared with mouse parotid glands, there are more secretary granules in acinar cells and vascular endothelial cells in miniature pig parotid glands, which might enter blood stream and have function of endocrine secretion.

  5. Is distal motor and/or sensory demyelination a distinctive feature of anti-MAG neuropathy?

    PubMed

    Lozeron, Pierre; Ribrag, Vincent; Adams, David; Brisset, Marion; Vignon, Marguerite; Baron, Marine; Malphettes, Marion; Theaudin, Marie; Arnulf, Bertrand; Kubis, Nathalie

    2016-09-01

    To report the frequency of the different patterns of sensory and motor electrophysiological demyelination distribution in patients with anti-MAG neuropathy in comparison with patients with IgM neuropathy without MAG reactivity (IgM-NP). Thirty-five anti-MAG patients at early disease stage (20.1 months) were compared to 23 patients with IgM-NP; 21 CIDP patients and 13 patients with CMT1a neuropathy were used as gold standard neuropathies with multifocal and homogeneous demyelination, respectively. In all groups, standard motor and sensory electrophysiological parameters, terminal latency index and modified F ratio were investigated. Motor electrophysiological demyelination was divided in four profiles: distal, homogeneous, proximal, and proximo-distal. Distal sensory and sensorimotor demyelination were evaluated. Anti-MAG neuropathy is a demyelinating neuropathy in 91 % of cases. In the upper limbs, reduced TLI is more frequent in anti-MAG neuropathy, compared to IgM-NP. But, predominant distal demyelination of the median nerve is encountered in only 43 % of anti-MAG neuropathy and is also common in IgM-NP (35 %). Homogeneous demyelination was the second most frequent pattern (31 %). Concordance of electrophysiological profiles across motor nerves trunks is low and median nerve is the main site of distal motor conduction slowing. Reduced sensory conduction velocities occurs in 14 % of patients without evidence of predominant distal slowing. Simultaneous sensory and motor distal slowing was more common in the median nerve of anti-MAG neuropathy than IgM-NP. Electrophysiological distal motor demyelination and sensory demyelination are not a distinctive feature of anti-MAG reactivity. In anti-MAG neuropathy it is mainly found in the median nerve suggesting a frequent nerve compression at wrist.

  6. Probing circumplanetary disks with MagAO and ALMA

    NASA Astrophysics Data System (ADS)

    Wu, Ya-Lin

    2018-01-01

    The dedication of the Magellan Adaptive Optics (MagAO) on the 6.5 m Clay Telescope has opened a new era in high-contrast imaging. Its unique diffraction-limited wavelengths of 0.6 to 1 micron helps to probe circumplanetary disks by measuring the amount of dust reddening as well as by searching for the strongest gas accretion indicator H-alpha (0.65 micron). Using MagAO, I found that two wide-orbit planetary-mass companions CT Cha B and 1RXS 1609 B have a significant dust extinction of Av ~ 3 to 5 mag likely from their disks. For GQ Lup B, I found that it is actively accreting material from its disk and emitting strong H-alpha emission. My research with MagAO demonstrates that circumplanetary disks could be ubiquitous among young giant planets. I later carried out a survey using ALMA to image accretion disks around several wide planet-mass companions at 1.3 mm continuum and CO (2-1). This is the first systematic study aiming to measure the size, mass, and structure of planetary disks. However, except for FW Tau C (which was shown to actually be a low-mass star from the dynamical mass measurement) no disks around the companions were found in my ALMA survey. This surprising null result implies that circumplanetary disks are much more compact and denser than expected, so they are faint and optically thick in the radio wavelengths. Therefore, mid- to far-infrared may be more favorable to characterize disk properties. The MIRI camera on the JWST can test this compact optically-thick disk hypothesis by probing disk thermal emission between 10 and 25 micron.

  7. 19 CFR 10.537 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... parts, or tools will be taken into account as originating or non-originating materials, as the case may... 19 Customs Duties 1 2010-04-01 2010-04-01 false Accessories, spare parts, or tools. 10.537 Section... Free Trade Agreement Rules of Origin § 10.537 Accessories, spare parts, or tools. Accessories, spare...

  8. A preliminary study of the thermal measurement with nMAG gel dosimeter by MRI

    NASA Astrophysics Data System (ADS)

    Chuang, Chun-Chao; Shao, Chia-Ho; Shih, Cheng-Ting; Yeh, Yu-Chen; Lu, Cheng-Chang; Chuang, Keh-Shih; Wu, Jay

    2014-11-01

    The methacrylic acid (nMAG) gel dosimeter is an effective tool for 3-dimensional quality assurance of radiation therapy. In addition to radiation induced polymerization effects, the nMAG gel also responds to temperature variation. In this study, we proposed a new method to evaluate the thermal response in thermal therapy using nMAG gel and magnetic resonance image (MRI) scans. Several properties of nMAG have been investigated including the R2 relaxation rate, temperature sensitivity, and temperature linearity of the thermal dose response. nMAG was heated by the double-boiling method in the range of 37-45 °C. MRI scans were performed with the head coil receiver. The temperature to R2 response curve was analyzed and simple linear regression was performed with an R-square value of 0.9835. The measured data showed a well inverse linear relationship between R2 and temperature. We conclude that the nMAG polymer gel dosimeter shows great potential as a technique to evaluate the temperature rise during thermal surgery.

  9. Morphology and volatile compounds of metathoracic scent gland in Tessaratoma papillosa (Drury) (Hemiptera: Tessaratomidae).

    PubMed

    Zhao, D; Gao, J; Wang, Y; Jiang, J; Li, R

    2012-08-01

    Tessaratoma papillosa (Drury) (Hemiptera: Tessaratomidae) is a serious insect pest of litchi and longan in South China. When disturbed, this insect could release large quantities of disagreeable odorous volatiles from its scent gland. Knowledge on the scent gland and its secretion is crucial for developing the semiochemical methods to manage this pest. Morphology and ultrastructure of the metathoracic scent glands (MTGs) were studied under stereo and scanning electron microscopy, and the volatile compounds of MTGs from both male and female T. papillosa were analyzed with coupled gas chromatography-mass spectrometry (GC-MS). The MTG complex is located between the metathorax and the first abdominal segment at the ventral surface of the insect, which has a well-developed single double valve cystic-shaped orange median reservoir, paired colorless lateral glands in both sides, and a long and wavy tubular accessory gland that inlays tightly into the ventral edge around the median reservoir. The MTG opens to the body surface through paired ostioles located between the meso- and metacoxae of the evaporatorium with mushroom bodies. The GC-MS analyses showed that female and male adults have nine major volatile components in common. Tridecane is the most abundant in both females and males, reaching up to 47.1% and 51.8% of relative amount, respectively. The minor component is benzophenone with only 0.28% and 0.14%. Furthermore, undecane, tetradecane, 3-methyl-tridecane, and cyclopentadecane were found only in males. The possible function of volatile compounds of MTG contents in T. papillosa is addressed.

  10. Evaluation of Accessory Lacrimal Gland in Muller’s Muscle Conjunctival Resection Specimens for Precursor Cell Markers and Biological Markers of Dry Eye Disease

    PubMed Central

    Ali, Marwan; Shah, Dhara; Pasha, Zeeshan; Jassim, Sarmad H.; Jaboori, Assraa Jassim; Setabutr, Pete; Aakalu, Vinay K.

    2017-01-01

    Purpose The accessory lacrimal glands (ALG) are an understudied component of the tear functional unit, even though they are important in the development of dry eye syndrome (DES). To advance our understanding of aging changes, regenerative potential and histologic correlates to human characteristics, we investigated human ALG tissue from surgical samples to determine the presence or absence of progenitor cell markers and lacrimal epithelial markers and to correlate marker expression to relevant patient characteristics. Materials and Methods ALG tissues obtained from Muller’s Muscle Conjunctival Resection (MMCR) specimens were created using tissue microarrays (TMAs). Immunofluorescence staining of MMCR sections was performed using primary antibodies specific to cell protein markers. Cell marker localization in TMAs was then assessed by two blinded observers using a standardized scoring system. Patient characteristics including age, race, and status of ocular surface health were then compared against expression of stem cell markers. Results Human ALG expressed a number of epithelial markers, and in particular, histatin-1 was well correlated with the expression of epithelial markers and was present in most acini. In addition, we noted the presence of precursor cell markers nestin, ABCG2 and CD90 in ALG tissue. There was a decrease in precursor cell marker expression with increasing age. Finally, we noted that a negative association was present between histatin-1 expression and DES. Conclusions Thus, we report for the first time that human ALG tissues contain precursor marker positive cells and that this marker expression may decrease with increasing age. Moreover, histatin-1 expression may be decreased in DES. Future studies will be performed to use these cell markers to isolate and culture lacrimal epithelial cells from heterogeneous tissues, determine the relevance of histatin-1 expression to DES and isolate candidate precursor cells from ALG tissue. PMID:27612554

  11. 21 CFR 886.1930 - Tonometer and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1930 Tonometer and accessories. (a) Identification. A tonometer and accessories is a manual device intended to measure intraocular pressure by applying a known force on the globe of the eye and measuring the amount of indentation produced (Schiotz...

  12. 21 CFR 864.3600 - Microscopes and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Microscopes and accessories. 864.3600 Section 864.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864.3600...

  13. 21 CFR 864.3600 - Microscopes and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Microscopes and accessories. 864.3600 Section 864.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864.3600...

  14. 21 CFR 864.3600 - Microscopes and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Microscopes and accessories. 864.3600 Section 864.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864.3600...

  15. 21 CFR 864.3600 - Microscopes and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Microscopes and accessories. 864.3600 Section 864.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864.3600...

  16. Electronic Position Sensor for Power Operated Accessory

    DOEpatents

    Haag, Ronald H.; Chia, Michael I.

    2005-05-31

    An electronic position sensor for use with a power operated vehicle accessory, such as a power liftgate. The position sensor includes an elongated resistive circuit that is mounted such that it is stationary and extends along the path of a track portion of the power operated accessory. The position sensor further includes a contact nub mounted to a link member that moves within the track portion such that the contact nub is slidingly biased against the elongated circuit. As the link member moves under the force of a motor-driven output gear, the contact nub slides along the surface of the resistive circuit, thereby affecting the overall resistance of the circuit. The position sensor uses the overall resistance to provide an electronic position signal to an ECU, wherein the signal is indicative of the absolute position of the power operated accessory. Accordingly, the electronic position sensor is capable of providing an electronic signal that enables the ECU to track the absolute position of the power operated accessory.

  17. MAG3D and its application to internal flowfield analysis

    NASA Technical Reports Server (NTRS)

    Lee, K. D.; Henderson, T. L.; Choo, Y. K.

    1992-01-01

    MAG3D (multiblock adaptive grid, 3D) is a 3D solution-adaptive grid generation code which redistributes grid points to improve the accuracy of a flow solution without increasing the number of grid points. The code is applicable to structured grids with a multiblock topology. It is independent of the original grid generator and the flow solver. The code uses the coordinates of an initial grid and the flow solution interpolated onto the new grid. MAG3D uses a numerical mapping and potential theory to modify the grid distribution based on properties of the flow solution on the initial grid. The adaptation technique is discussed, and the capability of MAG3D is demonstrated with several internal flow examples. Advantages of using solution-adaptive grids are also shown by comparing flow solutions on adaptive grids with those on initial grids.

  18. 21 CFR 878.1800 - Speculum and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Speculum and accessories. 878.1800 Section 878.1800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Diagnostic Devices § 878.1800 Speculum and accessories...

  19. 21 CFR 878.1800 - Speculum and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Speculum and accessories. 878.1800 Section 878.1800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Diagnostic Devices § 878.1800 Speculum and accessories...

  20. 21 CFR 878.1800 - Speculum and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Speculum and accessories. 878.1800 Section 878.1800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Diagnostic Devices § 878.1800 Speculum and accessories...

  1. 21 CFR 878.1800 - Speculum and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Speculum and accessories. 878.1800 Section 878.1800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Diagnostic Devices § 878.1800 Speculum and accessories...

  2. 21 CFR 878.1800 - Speculum and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Speculum and accessories. 878.1800 Section 878.1800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Diagnostic Devices § 878.1800 Speculum and accessories...

  3. Magnetically separable polymer (Mag-MIP) for selective analysis of biotin in food samples.

    PubMed

    Uzuriaga-Sánchez, Rosario Josefina; Khan, Sabir; Wong, Ademar; Picasso, Gino; Pividori, Maria Isabel; Sotomayor, Maria Del Pilar Taboada

    2016-01-01

    This work presents an efficient method for the preparation of magnetic nanoparticles modified with molecularly imprinted polymers (Mag-MIP) through core-shell method for the determination of biotin in milk food samples. The functional monomer acrylic acid was selected from molecular modeling, EGDMA was used as cross-linking monomer and AIBN as radical initiator. The Mag-MIP and Mag-NIP were characterized by FTIR, magnetic hysteresis, XRD, SEM and N2-sorption measurements. The capacity of Mag-MIP for biotin adsorption, its kinetics and selectivity were studied in detail. The adsorption data was well described by Freundlich isotherm model with adsorption equilibrium constant (KF) of 1.46 mL g(-1). The selectivity experiments revealed that prepared Mag-MIP had higher selectivity toward biotin compared to other molecules with different chemical structure. The material was successfully applied for the determination of biotin in diverse milk samples using HPLC for quantification of the analyte, obtaining the mean value of 87.4% recovery. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Solar Probe Plus MAG Sensor Thermal Design for Low Heater Power and Extreme Thermal Environment

    NASA Technical Reports Server (NTRS)

    Choi, Michael K.

    2015-01-01

    The heater power available for the Solar Probe Plus FIELDS MAG sensor is less than half of the heritage value for other missions. Nominally the MAG sensors are in the spacecraft's umbra. In the worst hot case, approximately 200 spacecraft communication downlinks, up to 10 hours each, are required at 0.7 AU. These downlinks require the spacecraft to slew 45 deg. about the Y-axis, exposing the MAG sensors and boom to sunlight. This paper presents the thermal design to meet the MAG sensor thermal requirements in the extreme thermal environment and with low heater power. A thermal balance test on the MAG sensor engineering model has verified the thermal design and correlated the thermal model for flight temperature predictions.

  5. Development of a cryogenically cooled platform for the Magnetized Liner Inertial Fusion (MagLIF) Program [Development of a cryogenically-cooled platform for the Magnetized Liner Inertial Fusion (MagLIF) Concept

    DOE PAGES

    Awe, T. J.; Shelton, K. P.; Sefkow, A. B.; ...

    2017-09-25

    A cryogenically cooled hardware platform has been developed and commissioned on the Z Facility at Sandia National Laboratories in support of the Magnetized Liner Inertial Fusion (MagLIF) Program. MagLIF is a magneto-inertial fusion concept that employs a magnetically imploded metallic tube (liner) to compress and inertially confine premagnetized and preheated fusion fuel. The fuel is preheated using a ~2 kJ laser that must pass through a ~1.5-3.5-μm-thick polyimide “window” at the target’s laser entrance hole (LEH). As the terawatt-class laser interacts with the dense window, laser plasma instabilities (LPIs) can develop, which reduce the preheat energy delivered to the fuel,more » initiate fuel contamination, and degrade target performance. Cryogenically cooled targets increase the parameter space accessible to MagLIF target designs by allowing nearly 10 times thinner windows to be used for any accessible gas density. Thinner LEH windows reduce the deleterious effects of difficult to model LPIs. The Z Facility’s cryogenic infrastructure has been significantly altered to enable compatibility with the premagnetization and fuel preheat stages of MagLIF. The MagLIF cryostat brings the liquid helium coolant directly to the target via an electrically resistive conduit. This design maximizes cooling power while allowing rapid diffusion of the axial magnetic field supplied by external Helmholtz-like coils. A variety of techniques have been developed to mitigate the accumulation of ice from vacuum chamber contaminants on the cooled LEH window, as even a few hundred nanometers of ice would impact laser energy coupling to the fuel region. Here, the MagLIF cryostat has demonstrated compatibility with the premagnetization and preheat stages of MagLIF and the ability to cool targets to liquid deuterium temperatures in approximately 5 min.« less

  6. Development of a cryogenically cooled platform for the Magnetized Liner Inertial Fusion (MagLIF) Program [Development of a cryogenically-cooled platform for the Magnetized Liner Inertial Fusion (MagLIF) Concept

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Awe, T. J.; Shelton, K. P.; Sefkow, A. B.

    A cryogenically cooled hardware platform has been developed and commissioned on the Z Facility at Sandia National Laboratories in support of the Magnetized Liner Inertial Fusion (MagLIF) Program. MagLIF is a magneto-inertial fusion concept that employs a magnetically imploded metallic tube (liner) to compress and inertially confine premagnetized and preheated fusion fuel. The fuel is preheated using a ~2 kJ laser that must pass through a ~1.5-3.5-μm-thick polyimide “window” at the target’s laser entrance hole (LEH). As the terawatt-class laser interacts with the dense window, laser plasma instabilities (LPIs) can develop, which reduce the preheat energy delivered to the fuel,more » initiate fuel contamination, and degrade target performance. Cryogenically cooled targets increase the parameter space accessible to MagLIF target designs by allowing nearly 10 times thinner windows to be used for any accessible gas density. Thinner LEH windows reduce the deleterious effects of difficult to model LPIs. The Z Facility’s cryogenic infrastructure has been significantly altered to enable compatibility with the premagnetization and fuel preheat stages of MagLIF. The MagLIF cryostat brings the liquid helium coolant directly to the target via an electrically resistive conduit. This design maximizes cooling power while allowing rapid diffusion of the axial magnetic field supplied by external Helmholtz-like coils. A variety of techniques have been developed to mitigate the accumulation of ice from vacuum chamber contaminants on the cooled LEH window, as even a few hundred nanometers of ice would impact laser energy coupling to the fuel region. Here, the MagLIF cryostat has demonstrated compatibility with the premagnetization and preheat stages of MagLIF and the ability to cool targets to liquid deuterium temperatures in approximately 5 min.« less

  7. NK cells and their receptors in naive and rituximab-treated patients with anti-MAG polyneuropathy.

    PubMed

    Benedetti, Luana; Facco, Monica; Franciotta, Diego; Dalla Torre, Chiara; Campagnolo, Marta; Lucchetta, Marta; Boscaro, Elisa; Ermani, Mario; Del Sette, Massimo; Berno, Tamara; Candiotto, Laura; Zambello, Renato; Briani, Chiara

    2013-08-15

    Natural killer (NK) cells can bridge innate and acquired immunity, and play a role in autoimmunity. A few studies evaluated the distribution of NK cells and the expression of their receptors in chronic immune-mediated demyelinating polyneuropathies. We investigated NK cell distribution and NK cell receptor expression in 20 naïve patients with anti-MAG polyneuropathy (MAG-PN). Using flow cytometry, we analysed NK cells and a series of NK cell receptors in the peripheral blood of patients with MAG-PN, and, as controls, in patients with chronic inflammatory demyelinating peripheral polyradiculoneuropathy (CIDP) and in healthy subjects. Six MAG-PN patients were also tested after rituximab treatment. At baseline the percentage of NK cells did not differ among the groups. KIR2DL2 receptor expression in MAG-PN patients was higher, andCD94/NKG2A receptor expression in both MAG-PN and CIDP patients was lower than in healthy controls. These abnormalities did not correlate with any clinical or demographic variable. No modification was found after rituximab therapy. The data suggest that MAG-PN shows abnormalities in NK cell receptors that characterise other autoimmune diseases, and cannot help in differential diagnosis with CIDP. The impairment of the relevant CD94/NKG2A inhibitory pathway, which might play a central role in the development and perpetuation of MAG-PN, warrants further functional investigations. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. RW Per - Nodal motion changes its amplitude by 1.4 mag

    NASA Technical Reports Server (NTRS)

    Schaefer, Bradley E.; Fried, Robert E.

    1991-01-01

    RW Per was found to have large secular changes in its eclipse amplitude. In blue light, for example, the amplitude was 3.2 mag in the early 1900s, 2.2 mag in the late 1960s, and 1.75 mag in 1990. Throughout this time, the brightness at maximum was constant in all colors. It is shown that the only possible explanation is nodal motion, where the inclination varies with a period of roughly 100,000 yr. The nodal motion is caused by a third star, for which the light curve, the colors, and the O - C curve already provide evidence. Thus, RW Per is only the fourth known star with large changes of eclipse amplitude and is only the second example of nodal motion.

  9. Controlled Speed Accessory Drive demonstration program

    NASA Technical Reports Server (NTRS)

    Hoehn, F. W.

    1981-01-01

    A Controlled Speed Accessory Drive System was examined in an effort to improve the fuel economy of passenger cars. Concept feasibility and the performance of a typical system during actual road driving conditions were demonstrated. The CSAD system is described as a mechanical device which limits engine accessory speeds, thereby reducing parasitic horsepower losses and improving overall vehicle fuel economy. Fuel consumption data were compiled for fleets of GSA vehicles. Various motor pool locations were selected, each representing different climatic conditions. On the basis of a total accumulated fleet usage of nearly three million miles, an overall fuel economy improvement of 6 percent to 7 percent was demonstrated. Coincident chassis dynamometer tests were accomplished on selected vehicles to establish the effect of different accessory drive systems on exhaust emissions, and to evaluate the magnitude of the mileage benefits which could be derived.

  10. Accessory stimulus modulates executive function during stepping task

    PubMed Central

    Watanabe, Tatsunori; Koyama, Soichiro; Tanabe, Shigeo

    2015-01-01

    When multiple sensory modalities are simultaneously presented, reaction time can be reduced while interference enlarges. The purpose of this research was to examine the effects of task-irrelevant acoustic accessory stimuli simultaneously presented with visual imperative stimuli on executive function during stepping. Executive functions were assessed by analyzing temporal events and errors in the initial weight transfer of the postural responses prior to a step (anticipatory postural adjustment errors). Eleven healthy young adults stepped forward in response to a visual stimulus. We applied a choice reaction time task and the Simon task, which consisted of congruent and incongruent conditions. Accessory stimuli were randomly presented with the visual stimuli. Compared with trials without accessory stimuli, the anticipatory postural adjustment error rates were higher in trials with accessory stimuli in the incongruent condition and the reaction times were shorter in trials with accessory stimuli in all the task conditions. Analyses after division of trials according to whether anticipatory postural adjustment error occurred or not revealed that the reaction times of trials with anticipatory postural adjustment errors were reduced more than those of trials without anticipatory postural adjustment errors in the incongruent condition. These results suggest that accessory stimuli modulate the initial motor programming of stepping by lowering decision threshold and exclusively under spatial incompatibility facilitate automatic response activation. The present findings advance the knowledge of intersensory judgment processes during stepping and may aid in the development of intervention and evaluation tools for individuals at risk of falls. PMID:25925321

  11. Accessory Cavitated Uterine Mass: A Rare Cause of Severe Dysmenorrhea in Young Women.

    PubMed

    Paul, P G; Chopade, Gaurav; Das, Tanuka; Dhivya, N; Patil, Saurabh; Thomas, Manju

    2015-01-01

    We present 3 case reports of a rare Müllerian anomaly called accessory and cavitated uterine mass (ACUM), which is found in young women >30 years of age. They presented with severe dysmenorrhea refractory to medical treatment. The patients were 17, 19, and 25 years old. The patients had the classic Müllerian anomalies. The hysteroscopic examination was normal in all 3 cases, and laparoscopic examination showed a 3- to 4-cm ill-defined mass on the right half of the uterus, without any communication to the uterine cavity. The chocolate-colored material was drained in all of the cases, during excision of the mass. The myometrial defect was sutured laparoscopically. On histological examination, the mass was found to be a cystic cavity, lined by endometrial glands and stroma, which confirmed the diagnosis of ACUM. Copyright © 2015 AAGL. Published by Elsevier Inc. All rights reserved.

  12. FastMag: Fast micromagnetic simulator for complex magnetic structures (invited)

    NASA Astrophysics Data System (ADS)

    Chang, R.; Li, S.; Lubarda, M. V.; Livshitz, B.; Lomakin, V.

    2011-04-01

    A fast micromagnetic simulator (FastMag) for general problems is presented. FastMag solves the Landau-Lifshitz-Gilbert equation and can handle multiscale problems with a high computational efficiency. The simulator derives its high performance from efficient methods for evaluating the effective field and from implementations on massively parallel graphics processing unit (GPU) architectures. FastMag discretizes the computational domain into tetrahedral elements and therefore is highly flexible for general problems. The magnetostatic field is computed via the superposition principle for both volume and surface parts of the computational domain. This is accomplished by implementing efficient quadrature rules and analytical integration for overlapping elements in which the integral kernel is singular. Thus, discretized superposition integrals are computed using a nonuniform grid interpolation method, which evaluates the field from N sources at N collocated observers in O(N) operations. This approach allows handling objects of arbitrary shape, allows easily calculating of the field outside the magnetized domains, does not require solving a linear system of equations, and requires little memory. FastMag is implemented on GPUs with ?> GPU-central processing unit speed-ups of 2 orders of magnitude. Simulations are shown of a large array of magnetic dots and a recording head fully discretized down to the exchange length, with over a hundred million tetrahedral elements on an inexpensive desktop computer.

  13. 14 CFR 23.1437 - Accessories for multiengine airplanes.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Accessories for multiengine airplanes. 23... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Miscellaneous Equipment § 23.1437 Accessories for multiengine airplanes. For multiengine airplanes...

  14. 14 CFR 23.1437 - Accessories for multiengine airplanes.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Accessories for multiengine airplanes. 23... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Miscellaneous Equipment § 23.1437 Accessories for multiengine airplanes. For multiengine airplanes...

  15. 14 CFR 23.1437 - Accessories for multiengine airplanes.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Accessories for multiengine airplanes. 23... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Miscellaneous Equipment § 23.1437 Accessories for multiengine airplanes. For multiengine airplanes...

  16. A background correction algorithm for Van Allen Probes MagEIS electron flux measurements

    DOE PAGES

    Claudepierre, S. G.; O'Brien, T. P.; Blake, J. B.; ...

    2015-07-14

    We describe an automated computer algorithm designed to remove background contamination from the Van Allen Probes Magnetic Electron Ion Spectrometer (MagEIS) electron flux measurements. We provide a detailed description of the algorithm with illustrative examples from on-orbit data. We find two primary sources of background contamination in the MagEIS electron data: inner zone protons and bremsstrahlung X-rays generated by energetic electrons interacting with the spacecraft material. Bremsstrahlung X-rays primarily produce contamination in the lower energy MagEIS electron channels (~30–500 keV) and in regions of geospace where multi-M eV electrons are present. Inner zone protons produce contamination in all MagEIS energymore » channels at roughly L < 2.5. The background-corrected MagEIS electron data produce a more accurate measurement of the electron radiation belts, as most earlier measurements suffer from unquantifiable and uncorrectable contamination in this harsh region of the near-Earth space environment. These background-corrected data will also be useful for spacecraft engineering purposes, providing ground truth for the near-Earth electron environment and informing the next generation of spacecraft design models (e.g., AE9).« less

  17. Binding specificity of anti-HNK-1 IgM M-protein in anti-MAG neuropathy: possible clinical relevance.

    PubMed

    Hamada, Yukihiro; Hirano, Makito; Kuwahara, Motoi; Samukawa, Makoto; Takada, Kazuo; Morise, Jyoji; Yabuno, Keiko; Oka, Shogo; Kusunoki, Susumu

    2015-02-01

    Anti-myelin-associated-glycoprotein (MAG) neuropathy is an intractable autoimmune polyneuropathy. The antigenic region of MAG is the human natural killer-1 (HNK-1) carbohydrate. We and others previously suggested that the extension of antibody reactivities to HNK-1-bearing proteins other than MAG was associated with treatment resistance, without statistical analyses. In this study, we established an ELISA method with recombinant proteins to test binding specificities of currently available monoclonal antibodies to MAG and another HNK-1-bearing protein, phosphacan. Using this system, we found the distinct binding specificities of anti-MAG antibody in 19 patients with anti-MAG neuropathy. Their clinical relevance was then determined retrospectively with the adjusted 10-points INCAT disability score (0 = normal and 10 = highly disable). The results showed that strong reactivities of anti-MAG antibodies to phosphacan were significantly associated with treatment resistance or progressive clinical courses, indicating a possible clinical relevance of the binding specificities. Copyright © 2014 Elsevier Ireland Ltd and the Japan Neuroscience Society. All rights reserved.

  18. Pathogenesis and Treatment of Anti-MAG Neuropathy.

    PubMed

    Dalakas, Marinos C

    2010-03-01

    Polyneuropathies associated with IgM monoclonal gammopathies comprise a distinct entity. In spite of the apparent pathogenicity of the IgM antibodies and the specific immunoreactivity to myelin antigens, the disease has been difficult to treat. This review describes the clinical phenotype, addresses recent data on immunoreactivity of IgM to various nerve antigens, and discusses the latest progress on treatment.Most of these patients present with paresthesias and sensory ataxia followed by a varying degree of sensorimotor deficits. In more than 75% of the patients, the monoclonal IgM recognizes myelin-associated glycoprotein (MAG) and sulfoglucuronyl glycosphingolipid (SGPG), best detected by ELISA, or other peripheral nerve glycolipids. Recent experiments have demonstrated that animals immunized with SGPG develop sensory ataxia, suggesting a pathogenic role for this antigen. Although cladribine, cyclophosphamide with prednisone, and intravenous immunoglobulin have offered transient benefits to some patients, most have remained treatment-resistant. Open label studies and a recent randomized controlled trial indicate that rituximab is emerging as the best agent available, providing long-term benefits to almost half of these patients. Rituximab appears to work by suppressing the IgM as well as the anti-MAG antibodies and by inducing immunoregulatory T cells. Patients with more sensory deficits and higher anti-MAG antibodies are more likely to respond but may require re-treatment after several months.These encouraging results need confirmation with a larger trial. Data on long-term efficacy and immune markers associated with response to therapy or need for re-treatment are still needed.

  19. Detecting De-gelation through Tissue Using Magnetically Modulated Optical Nanoprobes (MagMOONs)

    PubMed Central

    Nguyen, KhanhVan T.; Anker, Jeffrey N.

    2014-01-01

    Alginate gels are widely used for drug delivery and implanted devices. The rate at which these gels break down is important for controlling drug release. Since the de-gelation may be different in vivo, monitoring this process in situ is essential. However, it is challenging to monitor the gel through tissue due to optical scattering and tissue autofluorescence. Herein we describe a method to detect through tissue the chemically-induced changes in viscosity and de-gelation process of alginate gels using magnetically modulated optical nanoprobes (MagMOONs). The MagMOONs are fluorescent magnetic microspheres coated with a thin layer of opaque metal on one hemisphere. The metal layer prevents excitation and emission light from passing through one side of the MagMOONs, which creates orientation-dependent fluorescence intensity. The magnetic particles also align in an external magnetic field and give blinking signals when they rotate to follow an external modulated magnetic field. The blinking signals from these MagMOONs are distinguished from background autofluorescence and can be tracked on a single particle level in the absence of tissue, or for an ensemble average of particles blinking through tissue. When these MagMOONs are dispersed in calcium alginate gel, they become sensors for detecting gel degradation upon addition of either ammonium ion or alginate lyase. Our results show MagMOONs start blinking approximately 10 minutes after 2 mg/mL alginate lyase addition and this blinking is clearly detected even through up to 4 mm chicken breast. This approach can potentially be employed to detect bacterial biofilm formation on medical implants by sensing specific proteases that either activate a related function or regulate biofilm formation. It can also be applied to other biosensors and drug delivery systems based on enzyme-catalyzed breakdown of gel components. PMID:26273129

  20. Detecting De-gelation through Tissue Using Magnetically Modulated Optical Nanoprobes (MagMOONs).

    PubMed

    Nguyen, KhanhVan T; Anker, Jeffrey N

    2014-12-15

    Alginate gels are widely used for drug delivery and implanted devices. The rate at which these gels break down is important for controlling drug release. Since the de-gelation may be different in vivo , monitoring this process in situ is essential. However, it is challenging to monitor the gel through tissue due to optical scattering and tissue autofluorescence. Herein we describe a method to detect through tissue the chemically-induced changes in viscosity and de-gelation process of alginate gels using magnetically modulated optical nanoprobes (MagMOONs). The MagMOONs are fluorescent magnetic microspheres coated with a thin layer of opaque metal on one hemisphere. The metal layer prevents excitation and emission light from passing through one side of the MagMOONs, which creates orientation-dependent fluorescence intensity. The magnetic particles also align in an external magnetic field and give blinking signals when they rotate to follow an external modulated magnetic field. The blinking signals from these MagMOONs are distinguished from background autofluorescence and can be tracked on a single particle level in the absence of tissue, or for an ensemble average of particles blinking through tissue. When these MagMOONs are dispersed in calcium alginate gel, they become sensors for detecting gel degradation upon addition of either ammonium ion or alginate lyase. Our results show MagMOONs start blinking approximately 10 minutes after 2 mg/mL alginate lyase addition and this blinking is clearly detected even through up to 4 mm chicken breast. This approach can potentially be employed to detect bacterial biofilm formation on medical implants by sensing specific proteases that either activate a related function or regulate biofilm formation. It can also be applied to other biosensors and drug delivery systems based on enzyme-catalyzed breakdown of gel components.

  1. 21 CFR 876.5820 - Hemodialysis system and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    .... (1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air... conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system...

  2. 21 CFR 876.5820 - Hemodialysis system and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... (1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air... conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system...

  3. 21 CFR 876.5820 - Hemodialysis system and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    .... (1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air... conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system...

  4. 21 CFR 876.5820 - Hemodialysis system and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    .... (1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air... conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system...

  5. 14 CFR 23.1437 - Accessories for multiengine airplanes.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Accessories for multiengine airplanes. 23.1437 Section 23.1437 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF..., engine-driven accessories essential to safe operation must be distributed among two or more engines so...

  6. 14 CFR 23.1437 - Accessories for multiengine airplanes.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Accessories for multiengine airplanes. 23.1437 Section 23.1437 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF..., engine-driven accessories essential to safe operation must be distributed among two or more engines so...

  7. A left lateral accessory pathway unmasked by rivastigmine.

    PubMed

    Guenancia, Charles; Fichot, Marie; Garnier, Fabien; Montoy, Mathieu; Laurent, Gabriel

    A 75-year-old woman was referred for advice regarding surface electrocardiographic modifications after the initiation of rivastigmine. In our patient, the baseline ECGs appeared perfectly normal. However, the initiation of a cholinesterase inhibitor unmasked a left lateral accessory pathway that had never been diagnosed before. Although cholinesterase inhibitors are known to increase vagal tone, the PR interval was shortened after rivastigmine administration, thus excluding this hypothesis to explain the appearance of the accessory pathway. Therefore, we hypothesized that cholinesterase inhibitors may have increased conduction velocity in the accessory pathway or in the atria. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. MagIC: Fluid dynamics in a spherical shell simulator

    NASA Astrophysics Data System (ADS)

    Wicht, J.; Gastine, T.; Barik, A.; Putigny, B.; Yadav, R.; Duarte, L.; Dintrans, B.

    2017-09-01

    MagIC simulates fluid dynamics in a spherical shell. It solves for the Navier-Stokes equation including Coriolis force, optionally coupled with an induction equation for Magneto-Hydro Dynamics (MHD), a temperature (or entropy) equation and an equation for chemical composition under both the anelastic and the Boussinesq approximations. MagIC uses either Chebyshev polynomials or finite differences in the radial direction and spherical harmonic decomposition in the azimuthal and latitudinal directions. The time-stepping scheme relies on a semi-implicit Crank-Nicolson for the linear terms of the MHD equations and a Adams-Bashforth scheme for the non-linear terms and the Coriolis force.

  9. A new contrast media for functional MR urography: Gd-MAG3.

    PubMed

    Algin, Oktay

    2011-07-01

    Tc-99m-MAG3 (tubular agent) provides high imaging quality and extraction efficiency; and has become one of the most widely used agent for scintigraphic examinations of urinary system pathologies and renal transplants. Recently, it was reported that functional magnetic resonance urography (FMRU) can be sufficient in detection of urinary tract obstruction, renal artery stenosis, calculation of kidney functions and evaluation of renal transplants. However the pharmacokinetics of magnetic resonance (MR) contrast-media used in FMRU and Tc-99m-MAG3 differs from each other. This may cause discordant results between the FMRU and most of the scintigraphic studies. To our knowledge, there is no contrast-media which is specific for FMRU. A kidney specific contrast material can be developed for FMRU studies as well. MAG3 is a good candidate for this chelation. In conclusion, MR imaging (MRI) will be the most useful and important technique for morphologic-functional evaluation of urinary system. FMRU examinations performed with MAG3 chelated gadolinium can be sufficient for the complete evaluation of urinary tract even in patients with impaired renal functions ("all in one MRI"). MRI has some important advantages including no risk for radiation exposure, high temporal and spatial resolution, no need for nephrotoxic contrast agent; besides being a fast and feasible technique. Gadolinium-containing contrast agents may cause a life-threatening adverse reaction known as nephrogenic systemic fibrosis in patients with severe renal impairment, but Gd-MAG3 may reduce the risk of nephrogenic systemic fibrosis due to its higher extraction capacity and other features. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Status analysis of keyhole bottom in laser-MAG hybrid welding process.

    PubMed

    Wang, Lin; Gao, Xiangdong; Chen, Ziqin

    2018-01-08

    The keyhole status is a determining factor of weld quality in laser-metal active gas arc (MAG) hybrid welding process. For a better evaluation of the hybrid welding process, three different penetration welding experiments: partial penetration, normal penetration (or full penetration), and excessive penetration were conducted in this work. The instantaneous visual phenomena including metallic vapor, spatters and keyhole of bottom surface were used to evaluate the keyhole status by a double high-speed camera system. The Fourier transform was applied on the bottom weld pool image for removing the image noise around the keyhole, and then the bottom weld pool image was reconstructed through the inverse Fourier transform. Lastly, the keyhole bottom was extracted from the de-noised bottom weld pool image. By analyzing the visual features of the laser-MAG hybrid welding process, mechanism of the closed and opened keyhole bottom were revealed. The results show that the stable opened or closed status of keyhole bottom is directly affected by the MAG droplet transition in the normal penetration welding process, and the unstable opened or closed status of keyhole bottom would appear in excessive penetration welding and partial penetration welding. The analysis method proposed in this paper could be used to monitor the keyhole stability in laser-MAG hybrid welding process.

  11. 21 CFR 884.5350 - Contraceptive diaphragm and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Contraceptive diaphragm and accessories. 884.5350 Section 884.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Devices § 884.5350 Contraceptive diaphragm and accessories. (a) Identification. A contraceptive diaphragm...

  12. 21 CFR 884.5350 - Contraceptive diaphragm and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Contraceptive diaphragm and accessories. 884.5350 Section 884.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Devices § 884.5350 Contraceptive diaphragm and accessories. (a) Identification. A contraceptive diaphragm...

  13. 21 CFR 884.5350 - Contraceptive diaphragm and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contraceptive diaphragm and accessories. 884.5350 Section 884.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Devices § 884.5350 Contraceptive diaphragm and accessories. (a) Identification. A contraceptive diaphragm...

  14. 21 CFR 884.5350 - Contraceptive diaphragm and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Contraceptive diaphragm and accessories. 884.5350 Section 884.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Devices § 884.5350 Contraceptive diaphragm and accessories. (a) Identification. A contraceptive diaphragm...

  15. 21 CFR 884.5350 - Contraceptive diaphragm and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Contraceptive diaphragm and accessories. 884.5350 Section 884.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Devices § 884.5350 Contraceptive diaphragm and accessories. (a) Identification. A contraceptive diaphragm...

  16. Iron oxide nanoparticles modulate heat shock proteins and organ specific markers expression in mice male accessory organs.

    PubMed

    Sundarraj, Kiruthika; Raghunath, Azhwar; Panneerselvam, Lakshmikanthan; Perumal, Ekambaram

    2017-02-15

    With increased industrial utilization of iron oxide nanoparticles (Fe 2 O 3 -NPs), concerns on adverse reproductive health effects following exposure have been immensely raised. In the present study, the effects of Fe 2 O 3 -NPs exposure in the seminal vesicle and prostate gland were studied in mice. Mice were exposed to two different doses (25 and 50 mg/kg) of Fe 2 O 3 -NPs along with the control and analyzed the expressions of heat shock proteins (HSP60, HSP70 and HSP90) and organ specific markers (Caltrin, PSP94, and SSLP1). Fe 2 O 3 -NPs decreased food consumption, water intake, and organo-somatic index in mice with elevated iron levels in serum, urine, fecal matter, seminal vesicle and prostate gland. FTIR spectra revealed alterations in the functional groups of biomolecules on Fe 2 O 3 -NPs treatment. These changes are accompanied by increased lactate dehydrogenase levels with decreased total protein and fructose levels. The investigation of oxidative stress biomarkers demonstrated a significant increase in reactive oxygen species, nitric oxide, lipid peroxidation, protein carbonyl content and glutathione peroxidase with a concomitant decrement in the glutathione and ascorbic acid in the male accessory organs which confirmed the induction of oxidative stress. An increase in NADPH-oxidase-4 with a decrease in glutathione-S-transferase was observed in the seminal vesicle and prostate gland of the treated groups. An alteration in HSP60, HSP70, HSP90, Caltrin, PSP94, and SSLP1 expression was also observed. Moreover, accumulation of Fe 2 O 3 -NPs brought pathological changes in the seminal vesicle and prostate gland of treated mice. These findings provide evidence that Fe 2 O 3 -NPs could be an environmental risk factor for reproductive disease. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. [Mucoepidermoid carcinoma of salivary glands: the prognostic value of tumoral markers].

    PubMed

    Hoyek-Gebeily, J; Nehmé, E; Aftimos, G; Sader-Ghorra, C; Sargi, Z; Haddad, A

    2007-12-01

    Mucoepidermoid carcinoma is one of the most frequent malignant lesions of salivary glands. The treatment is based on clinical, paraclinical and histological data. Several studies on the prognostic value of molecular markers for these cancers were made with contradictory results. The aim of this retrospective study was to analyze the prognostic value of molecular markers of salivary gland mucoepidermoid carcinoma. Sixteen patients were treated for mucoepidermoid carcinoma of principal and/or accessory salivary glands between 1994 and 2003. An immunohistochemical study of archive specimen was performed. Nine markers were specifically studied: 4 proteins/oncoproteins (p53, bcl2, c-erb-B2 and cd117), 2 markers of proliferation (PCNA and Ki67), 1 growing factor receptor (EGFR), 1 epithelial adhesion molecule (E-cadherin), and 1 angiogenic cytokine (PDGF). Nine men and 7 women were included, with a mean age of 43.7 years (14-80). The mean diameter of tumors was 3.1 mm (1-14), and the parotid gland was the most frequent location. The mean global survival rate was 57.3 months with a median of 55 months. The 2 to 5 years survival expectation rate were 82.5% and 46.4% respectively. The mean survival rate for women was superior to that of men (P=0.043). The expression of p53 and the high expression rate of EFGR were bad prognostic factors (respectively P=0.049 and P=0.012). The expression of PCNA was linked to the location (mainly the salivary gland) and to the diameter of the tumor (respectively P=0.037 and P=0.029). The degree of EFGR positivity and the histological grade were linked (P=0.027). The strong expression of EGFR was statistically linked to the histological tumor grade. The degree of PCNA positivity seemed to be associated to the preferential location in the main salivary glands and to the diameter of the tumor. The strong expression of p53 and EGFR were bad prognostic factors. These retrospective results need to be confirmed by prospective randomized and larger

  18. 21 CFR 884.4120 - Gynecologic electrocautery and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gynecologic electrocautery and accessories. 884.4120 Section 884.4120 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... under direct visual observation. This generic type of device may include the following accessories: an...

  19. 14 CFR 23.1192 - Engine accessory compartment diaphragm.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Engine accessory compartment diaphragm. 23... Powerplant Powerplant Fire Protection § 23.1192 Engine accessory compartment diaphragm. For aircooled radial engines, the engine power section and all portions of the exhaust sytem must be isolated from the engine...

  20. 14 CFR 23.1192 - Engine accessory compartment diaphragm.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Engine accessory compartment diaphragm. 23... Powerplant Powerplant Fire Protection § 23.1192 Engine accessory compartment diaphragm. For aircooled radial engines, the engine power section and all portions of the exhaust sytem must be isolated from the engine...

  1. 14 CFR 23.1192 - Engine accessory compartment diaphragm.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Engine accessory compartment diaphragm. 23... Powerplant Powerplant Fire Protection § 23.1192 Engine accessory compartment diaphragm. For aircooled radial engines, the engine power section and all portions of the exhaust sytem must be isolated from the engine...

  2. 21 CFR 876.4890 - Urological table and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., stirrups, and belts used to support a patient in a suitable position for endoscopic procedures of the lower...) Class II (special controls) for the electrically powered urological table and accessories. The device is... § 876.9. (2) Class I for the manually powered table and accessories, and for stirrups for electrically...

  3. Sperm collection by transrectal ultrasound-guided massage of the accessory sex glands is less stressful than electroejaculation without altering sperm characteristics in conscious goat bucks.

    PubMed

    Abril-Sánchez, Silvia; Freitas-de-Melo, Aline; Beracochea, Florencia; Damián, Juan Pablo; Giriboni, Julia; Santiago-Moreno, Julián; Ungerfeld, Rodolfo

    2017-08-01

    In anesthetized non-domestic ruminants transrectal ultrasound-guided massage of the accessory sex glands (TUMASG) is an alternative method to collect semen slightly less stressful than electroejaculation (EE). However, some sperm characteristics are better when semen is collected with EE than with TUMASG. As anesthesia reduces the response to stressors, the advantages of TUMASG may be reduced in anesthetized animals, and thus, TUMASG may be even more advantageous in conscious animals. Therefore, the aim of the present study was to compare the stress response and the characteristics of the sperm collected with TUMASG and EE in conscious goat bucks. Semen was collected in 10 bucks with both procedures. During each procedure, the time required for ejaculation, the number of electric pulses applied and the number of vocalizations were recorded. Rectal temperature, heart rate, serum cortisol concentration, biochemical and hematological parameters were measured before and after each procedure. Sperm characteristics [ejaculated volume, sperm concentration, sperm mass motility (scale 0-5), sperm vigor (scale 0-5), the percentages of motile and progressive motile sperm, of sperm vitality, of sperm with plasma membrane integrity, and with acrosome damage and morphological abnormalities] were also determined. Electroejaculation required more electric pulses than TUMASG (P < 0.0001), but TUMASG took more time than EE (P < 0.0001). The EE provoked more vocalizations (P = 0.02) and a greater increase of cortisol concentrations than TUMASG (P = 0.04). Heart rate also tended to be greater with EE than with TUMASG (P = 0.07). The sperm characteristics did not differ between TUMASG and EE. In conclusion, TUMASG was less stressful and probably less painful than EE without affecting the semen quality. Thus, although it required more time, TUMASG is an alternative procedure to decrease the welfare concerns raised by EE in conscious goat bucks. Copyright © 2017 Elsevier Inc

  4. 14 CFR 125.149 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Engine accessory section diaphragm. 125.149... Requirements § 125.149 Engine accessory section diaphragm. Unless equivalent protection can be shown by other means, a diaphragm that complies with § 125.145 must be provided on air-cooled engines to isolate the...

  5. 14 CFR 125.149 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Engine accessory section diaphragm. 125.149... Requirements § 125.149 Engine accessory section diaphragm. Unless equivalent protection can be shown by other means, a diaphragm that complies with § 125.145 must be provided on air-cooled engines to isolate the...

  6. 14 CFR 125.149 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Engine accessory section diaphragm. 125.149... Requirements § 125.149 Engine accessory section diaphragm. Unless equivalent protection can be shown by other means, a diaphragm that complies with § 125.145 must be provided on air-cooled engines to isolate the...

  7. 14 CFR 125.149 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Engine accessory section diaphragm. 125.149... Requirements § 125.149 Engine accessory section diaphragm. Unless equivalent protection can be shown by other means, a diaphragm that complies with § 125.145 must be provided on air-cooled engines to isolate the...

  8. MagAO: Status and on-sky performance of the Magellan adaptive optics system

    NASA Astrophysics Data System (ADS)

    Morzinski, Katie M.; Close, Laird M.; Males, Jared R.; Kopon, Derek; Hinz, Phil M.; Esposito, Simone; Riccardi, Armando; Puglisi, Alfio; Pinna, Enrico; Briguglio, Runa; Xompero, Marco; Quirós-Pacheco, Fernando; Bailey, Vanessa; Follette, Katherine B.; Rodigas, T. J.; Wu, Ya-Lin; Arcidiacono, Carmelo; Argomedo, Javier; Busoni, Lorenzo; Hare, Tyson; Uomoto, Alan; Weinberger, Alycia

    2014-07-01

    MagAO is the new adaptive optics system with visible-light and infrared science cameras, located on the 6.5-m Magellan "Clay" telescope at Las Campanas Observatory, Chile. The instrument locks on natural guide stars (NGS) from 0th to 16th R-band magnitude, measures turbulence with a modulating pyramid wavefront sensor binnable from 28×28 to 7×7 subapertures, and uses a 585-actuator adaptive secondary mirror (ASM) to provide at wavefronts to the two science cameras. MagAO is a mutated clone of the similar AO systems at the Large Binocular Telescope (LBT) at Mt. Graham, Arizona. The high-level AO loop controls up to 378 modes and operates at frame rates up to 1000 Hz. The instrument has two science cameras: VisAO operating from 0.5-1μm and Clio2 operating from 1-5 μm. MagAO was installed in 2012 and successfully completed two commissioning runs in 2012-2013. In April 2014 we had our first science run that was open to the general Magellan community. Observers from Arizona, Carnegie, Australia, Harvard, MIT, Michigan, and Chile took observations in collaboration with the MagAO instrument team. Here we describe the MagAO instrument, describe our on-sky performance, and report our status as of summer 2014.

  9. Rapid Development of Salivary Gland Carcinomas upon Conditional Expression of K-ras Driven by the Cytokeratin 5 Promoter

    PubMed Central

    Raimondi, Ana R.; Vitale-Cross, Lynn; Amornphimoltham, Panomwat; Gutkind, J. Silvio; Molinolo, Alfredo

    2006-01-01

    We have used a recently described model in which a ras oncogene is expressed in cytokeratin 5 (K5)-expressing cells on doxycycline administration to explore the effects of this oncogene in salivary glands of adult mice. Inducible expression of a mutated K-ras gene under the control of the K5 promoter led to the development of hyperplastic and dysplastic epithelial lesions and carcinomas, with an incidence of 100% and a minimum latency of a week. All major salivary glands were affected, as well as a set of previously undescribed buccal accessory salivary glands located on the apex of the masseter muscle, close to the oral angle. The tumors appear to arise from the cytokeratin 5-positive basal cell compartment. Myoepithelial cells participated in the hyperplasias but not in carcinomas, because the tumors are negative for smooth muscle actin. Carcinomas did not accumulate immunoreactive p53 but are positive for p63, as assayed by immunohistochemistry using an antibody against the N terminus of ΔN p63, a splice variant of p63 that can inhibit p53 transcriptional activity. In this study, we provide evidence that the ras oncogene, targeted to a specifically sensitive cell compartment within the salivary glands, can trigger a series of event that are sufficient for full carcinogenesis. PMID:16651631

  10. The CrowdMag App - turning your smartphone into a travelling magnetic observatory

    NASA Astrophysics Data System (ADS)

    Saltus, Richard; Nair, Manoj

    2017-04-01

    In 2014, we started the "CrowdMag" Project to collect vector magnetic data from digital magnetometers in smartphones. In October 2014, we released our first-generation Android and iOS apps. Currently, the CrowdMag Project has more than 15,000 enthusiastic users contributing more than 12 million magnetic data points from around the world. NOAA's National Centers for Environmental Information (NCEI), in partnership with the University of Colorado's Cooperative Institute for Research in the Environmental Sciences (CIRES) develops magnetic field models to aid navigation, resource exploration and scientific research. We use observatories, satellites and ship/airborne surveys to measure the magnetic data. However, the measurements leave gaps in coverage, particularly for short-wavelength urban noise. Our ultimate goal is to use data from the CrowdMag Project to improve global magnetic data coverage. Here we present some early results from the analysis of the crowdsourced magnetic data. A global magnetic model derived solely based on CrowdMag data is generally consistent with satellite-derived models such as World Magnetic Model. A unique contribution of the CrowdMag Project is the collection of ground level magnetic data in densely populated regions with an unprecedented spatial resolution. For example, we show a magnetic map (by binning the data collected into 100x100m cells) of central Boulder using 170,000 data points collected by about 60 devices over the duration October 2014- January 2016. The median magnetic field value is consistent with the expected magnitude of the Earth's background magnetic field. The standard deviation of the CrowdMag total field (F) values is much higher than the expected natural (i.e., diurnal and geologic) magnetic field variation. However, the phone's magnetometer is sensitive enough to capture the larger magnitude magnetic signature from the urban magnetic sources. We discuss the reliability of crowdsourced magnetic maps and their

  11. A New Interface for the Magnetics Information Consortium (MagIC) Paleo and Rock Magnetic Database

    NASA Astrophysics Data System (ADS)

    Jarboe, N.; Minnett, R.; Koppers, A. A. P.; Tauxe, L.; Constable, C.; Shaar, R.; Jonestrask, L.

    2014-12-01

    The Magnetic Information Consortium (MagIC) database (http://earthref.org/MagIC/) continues to improve the ease of uploading data, the creation of complex searches, data visualization, and data downloads for the paleomagnetic, geomagnetic, and rock magnetic communities. Data uploading has been simplified and no longer requires the use of the Excel SmartBook interface. Instead, properly formatted MagIC text files can be dragged-and-dropped onto an HTML 5 web interface. Data can be uploaded one table at a time to facilitate ease of uploading and data error checking is done online on the whole dataset at once instead of incrementally in an Excel Console. Searching the database has improved with the addition of more sophisticated search parameters and with the ability to use them in complex combinations. Searches may also be saved as permanent URLs for easy reference or for use as a citation in a publication. Data visualization plots (ARAI, equal area, demagnetization, Zijderveld, etc.) are presented with the data when appropriate to aid the user in understanding the dataset. Data from the MagIC database may be downloaded from individual contributions or from online searches for offline use and analysis in the tab delimited MagIC text file format. With input from the paleomagnetic, geomagnetic, and rock magnetic communities, the MagIC database will continue to improve as a data warehouse and resource.

  12. MAG4 Versus Alternative Techniques for Forecasting Active-Region Flare Productivity

    NASA Technical Reports Server (NTRS)

    Falconer, David A.; Moore, Ronald L.; Barghouty, Abdulnasser F.; Khazanov, Igor

    2014-01-01

    MAG4 (Magnetogram Forecast), developed originally for NASA/SRAG (Space Radiation Analysis Group), is an automated program that analyzes magnetograms from the HMI (Helioseismic and Magnetic Imager) instrument on NASA SDO (Solar Dynamics Observatory), and automatically converts the rate (or probability) of major flares (M- and X-class), Coronal Mass Ejections (CMEs), and Solar Energetic Particle Events. MAG4 does not forecast that a flare will occur at a particular time in the next 24 or 48 hours; rather the probability of one occurring.

  13. 21 CFR 884.2660 - Fetal ultrasonic monitor and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fetal ultrasonic monitor and accessories. 884.2660... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring Devices § 884.2660 Fetal ultrasonic monitor and accessories. (a) Identification. A fetal ultrasonic...

  14. 21 CFR 884.2660 - Fetal ultrasonic monitor and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fetal ultrasonic monitor and accessories. 884.2660... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring Devices § 884.2660 Fetal ultrasonic monitor and accessories. (a) Identification. A fetal ultrasonic...

  15. 21 CFR 884.2660 - Fetal ultrasonic monitor and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Fetal ultrasonic monitor and accessories. 884.2660... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring Devices § 884.2660 Fetal ultrasonic monitor and accessories. (a) Identification. A fetal ultrasonic...

  16. 21 CFR 874.4680 - Bronchoscope (flexible or rigid) and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... (flexible or rigid) and accessories. (a) Identification. A bronchoscope (flexible or rigid) and accessories... bronchoscope and is intended to examine or treat the larynx and tracheobronchial tree. It is typically used...

  17. Tissue-specific transcriptomics in the field cricket Teleogryllus oceanicus.

    PubMed

    Bailey, Nathan W; Veltsos, Paris; Tan, Yew-Foon; Millar, A Harvey; Ritchie, Michael G; Simmons, Leigh W

    2013-02-01

    Field crickets (family Gryllidae) frequently are used in studies of behavioral genetics, sexual selection, and sexual conflict, but there have been no studies of transcriptomic differences among different tissue types. We evaluated transcriptome variation among testis, accessory gland, and the remaining whole-body preparations from males of the field cricket, Teleogryllus oceanicus. Non-normalized cDNA libraries from each tissue were sequenced on the Roche 454 platform, and a master assembly was constructed using testis, accessory gland, and whole-body preparations. A total of 940,200 reads were assembled into 41,962 contigs, to which 36,856 singletons (reads not assembled into a contig) were added to provide a total of 78,818 sequences used in annotation analysis. A total of 59,072 sequences (75%) were unique to one of the three tissues. Testis tissue had the greatest proportion of tissue-specific sequences (62.6%), followed by general body (56.43%) and accessory gland tissue (44.16%). We tested the hypothesis that tissues expressing gene products expected to evolve rapidly as a result of sexual selection--testis and accessory gland--would yield a smaller proportion of BLASTx matches to homologous genes in the model organism Drosophila melanogaster compared with whole-body tissue. Uniquely expressed sequences in both testis and accessory gland showed a significantly lower rate of matching to annotated D. melanogaster genes compared with those from general body tissue. These results correspond with empirical evidence that genes expressed in testis and accessory gland tissue are rapidly evolving targets of selection.

  18. Improvements to the Magnetics Information Consortium (MagIC) Paleo and Rock Magnetic Database

    NASA Astrophysics Data System (ADS)

    Jarboe, N.; Minnett, R.; Tauxe, L.; Koppers, A. A. P.; Constable, C.; Jonestrask, L.

    2015-12-01

    The Magnetic Information Consortium (MagIC) database (http://earthref.org/MagIC/) continues to improve the ease of data uploading and editing, the creation of complex searches, data visualization, and data downloads for the paleomagnetic, geomagnetic, and rock magnetic communities. Online data editing is now available and the need for proprietary spreadsheet software is therefore entirely negated. The data owner can change values in the database or delete entries through an HTML 5 web interface that resembles typical spreadsheets in behavior and uses. Additive uploading now allows for additions to data sets to be uploaded with a simple drag and drop interface. Searching the database has improved with the addition of more sophisticated search parameters and with the facility to use them in complex combinations. A comprehensive summary view of a search result has been added for increased quick data comprehension while a raw data view is available if one desires to see all data columns as stored in the database. Data visualization plots (ARAI, equal area, demagnetization, Zijderveld, etc.) are presented with the data when appropriate to aid the user in understanding the dataset. MagIC data associated with individual contributions or from online searches may be downloaded in the tab delimited MagIC text file format for susbsequent offline use and analysis. With input from the paleomagnetic, geomagnetic, and rock magnetic communities, the MagIC database will continue to improve as a data warehouse and resource.

  19. Acute neurological worsening after Rituximab treatment in patients with anti-MAG neuropathy.

    PubMed

    Sala, Emilie; Robert-Varvat, Florence; Paul, Stéphane; Camdessanché, Jean-Philippe; Antoine, Jean-Christophe

    2014-10-15

    Patients with peripheral neuropathy and anti-MAG monoclonal IgM may respond to Rituximab, a humanized monoclonal anti-CD20 antibody. We report on three patients with peripheral neuropathy and anti-MAG monoclonal IgM who deteriorated under Rituximab and reviewed seven previously published cases. Worsening was acute and severe, and occurred during the treatment period. All the patients improved after deterioration but at final evaluation only one was improved comparatively to baseline, five were worsened and four were stabilized. Deterioration was not clearly associated with an increase of the anti-MAG antibody titer. Two patients received Rituximab prior or after the course which induced worsening without adverse reaction. Although rare, acute worsening of the neuropathy can occur after Rituximab. The deterioration is however reversible within some weeks to several months. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Accessory mental foramina and nerves: Application to periodontal, periapical, and implant surgery.

    PubMed

    Iwanaga, Joe; Watanabe, Koichi; Saga, Tsuyoshi; Tabira, Yoko; Kitashima, Sadaharu; Kusukawa, Jingo; Yamaki, Koh-Ichi

    2016-05-01

    Recent studies investigating accessory mental foramina using developments in diagnostic imaging have primarily defined the morphology of the foramina; however, few studies have described the structures passing through them. Additional clinical knowledge of the foramina is therefore required for preoperative diagnosis prior to surgery, including implant, periodontal and periapical surgery. In this study, we investigated the accessory mental foramina and the associated nerves and arteries in donated cadaveric mandibles using anatomical and radiological observation methods. We examined 63 mandibles with overlying soft tissue by cone-beam computed tomography and noted the existence of the accessory mental foramina. Mandibles with accessory mental foramina were subsequently analyzed. Additionally, the neurovascular bundles passing through these foramina were dissected using anatomical methods.The incidence of accessory mental foramina was 14.3%. The larger foramina tended to be located anteriorly or superiorly and proximal to the mental foramen, while the smaller foramina tended to be located posterosuperiorly and distal to the mental foramen. The mental foramen ipsilateral to the accessory mental foramen was smaller than the one contralateral to it. The comparatively distant and large accessory mental foramen included an artery.This study elucidated the relationship between accessory mental foramina and the associated nerves and arteries. We believe that the results will contribute to the clinical dentistry field. © 2015 Wiley Periodicals, Inc.

  1. Salivary Glands

    MedlinePlus

    ... salivary gland tumors usually show up as painless enlargements of these glands. Tumors rarely involve more than ... otolaryngologist-head and neck surgeon should check these enlargements. Malignant tumors of the major salivary glands can ...

  2. 21 CFR 884.2700 - Intrauterine pressure monitor and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Intrauterine pressure monitor and accessories. 884.2700 Section 884.2700 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... include the following accessories: signal analysis and display equipment, patient and equipment supports...

  3. 21 CFR 884.2640 - Fetal phonocardiographic monitor and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fetal phonocardiographic monitor and accessories. 884.2640 Section 884.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... includes the following accessories: signal analysis and display equipment, patient and equipment supports...

  4. 21 CFR 884.2640 - Fetal phonocardiographic monitor and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Fetal phonocardiographic monitor and accessories. 884.2640 Section 884.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... includes the following accessories: signal analysis and display equipment, patient and equipment supports...

  5. 21 CFR 884.2700 - Intrauterine pressure monitor and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intrauterine pressure monitor and accessories. 884.2700 Section 884.2700 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... include the following accessories: signal analysis and display equipment, patient and equipment supports...

  6. 21 CFR 884.2640 - Fetal phonocardiographic monitor and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Fetal phonocardiographic monitor and accessories. 884.2640 Section 884.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... includes the following accessories: signal analysis and display equipment, patient and equipment supports...

  7. 21 CFR 884.2640 - Fetal phonocardiographic monitor and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal phonocardiographic monitor and accessories. 884.2640 Section 884.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... includes the following accessories: signal analysis and display equipment, patient and equipment supports...

  8. 21 CFR 884.2640 - Fetal phonocardiographic monitor and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fetal phonocardiographic monitor and accessories. 884.2640 Section 884.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... includes the following accessories: signal analysis and display equipment, patient and equipment supports...

  9. 21 CFR 884.2700 - Intrauterine pressure monitor and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Intrauterine pressure monitor and accessories. 884.2700 Section 884.2700 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... include the following accessories: signal analysis and display equipment, patient and equipment supports...

  10. Salivary gland disease.

    PubMed

    Thomas, Bethan L; Brown, Jackie E; McGurk, Mark

    2010-01-01

    Salivary gland disease covers a wide range of pathological entities, including salivary gland-specific disease, as well as manifestations of systemic diseases. This chapter discusses the recent advances in managing obstructive salivary gland disease, the move from gland excision to gland preservation, the dilemmas in diagnosing and managing tumours of the salivary glands, and the international data collection to understand the aetiology and progression of Sjögren's disease. Copyright 2010 S. Karger AG, Basel.

  11. Complete Spinal Accessory Nerve Palsy From Carrying Climbing Gear.

    PubMed

    Coulter, Jess M; Warme, Winston J

    2015-09-01

    We report an unusual case of spinal accessory nerve palsy sustained while transporting climbing gear. Spinal accessory nerve injury is commonly a result of iatrogenic surgical trauma during lymph node excision. This particular nerve is less frequently injured by blunt trauma. The case reported here results from compression of the spinal accessory nerve for a sustained period-that is, carrying a load over the shoulder using a single nylon rope for 2.5 hours. This highlights the importance of using proper load-carrying equipment to distribute weight over a greater surface area to avoid nerve compression in the posterior triangle of the neck. The signs and symptoms of spinal accessory nerve palsy and its etiology are discussed. This report is particularly relevant to individuals involved in mountaineering and rock climbing but can be extended to anyone carrying a load with a strap over one shoulder and across the body. Copyright © 2015 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  12. Antigen-induced inhibition of autoimmune response to rat male accessory glands: distinct characteristics of I-A- and I-E-positive peritoneal cells.

    PubMed

    Rivero, V E; Ferro, M E; Romero-Piffiguer, M; Correa, S; Yranzo-Volonté, N; Riera, C M

    1991-05-01

    The present report describes different aspects of two populations of peritoneal cells (PC) obtained from rats injected i.p. 2 h or 24 h previously with a suppressor dose of a purified fraction (FI) of rat male accessory glands (RAG) (FI-PC2h and FI-PC24h, respectively). The FI-PC2h, which are mainly I-E (OX17) positive and can suppress the autoimmune response to RAG autoantigens, have an elevated phagocytic activity against Candida albicans and capacity to reduce the dye nitroblue tetrazolium. In contrast, FI-PC24h, which are mainly I-A (OX6) positive and can potentiate the autoimmunity to RAG autoantigens, have a diminished capacity to reduce the dye and a diminished phagocytic activity. Moreover, the Toxoplasma gondii appear to have a different effect on both populations. The parasites can invade FI-PC2h while FI-PC24h offer resistance to T. gondii aggression. FI-PC2h cultured during 22 h (FI-PC2-24h in vitro), or PC obtained from syngeneic recipients injected i.p. 22 h previously with FI-PC2h (FI-PC2-24h in vivo) show, as FI-PC2h, an increase of the I-E+ cells and capacity to induce suppression of the delayed-type hypersensitivity response to RAG autoantigens when they are injected to syngeneic rats 10 and 3 days prior to the immunization with chemically modified (diazotized arsanilic and sulfanilic acid) RAG in complete Freund's adjuvant. The PC obtained 24 h after injection of irradiated rats with N-PC plus FI show an increase of I-E+ cells whereas an enhancement of I-A+ cells can be observed when the PC are obtained 24 h after injection of irradiated and bone marrow-reconstituted rats with N-PC plus FI. These findings appear to indicate that FI-PC2h and FI-PC24h are functionally different and that the population obtained 24 h after injection of FI of RAG could not originate from either the population present 2 h after injection of FI of RAG injection nor from normal PC. They appear to require bone marrow precursors.

  13. Sexual behavior attenuates the effects of chronic stress in body weight, testes, sexual accessory glands, and plasma testosterone in male rats.

    PubMed

    Retana-Márquez, S; Vigueras-Villaseñor, R M; Juárez-Rojas, L; Aragón-Martínez, A; Torres, G Reyes

    2014-11-01

    The aim of this study was to evaluate whether continuous sexual behavior could attenuate the effects of chronic stress on spermatogenesis, sexual glands, plasma testosterone and corticosterone in sexually experienced male rats. Rats were exposed to stress by immersion in cold water (ICW) daily for 20 or 50 consecutive days. Plasma testosterone and corticosterone, masculine sexual behavior, as well as the number of offspring, the epithelial area of seminiferous, prostatic and seminal glands were assessed. In stressed males, body and testicular weights decreased, male sexual behavior was disrupted, and adrenal weights increased. In males stressed for 50 days, prostate and seminal glands had lower weights compared with controls. Prostate and seminal epithelial areas also decreased in these males. Seminiferous tubules in testes from rats stressed for 20 or 50 days showed several degenerative signs, such as vacuoles in the basal epithelium, with picnotic indicia; moderate to severe exfoliation of degenerative germinal cells in the tubule lumen was also observed. In males stressed for 50 days a significant decrease in seminiferous epithelial area was observed from stages I-VIII, regardless of copulation. The litters from females that copulated with males stressed for 50 days decreased significantly. Chronic stress caused increase in plasma levels of corticosterone, which were higher in males stressed for 20 days than in males stressed for 50 days. Testosterone decreased in stressed males and it was lower in males stressed for 50 days. In stressed males allowed to copulate, body and testicular weights were similar to controls. Adrenal, seminal glands, and prostate weights, as well as epithelial areas of males stressed for 50 days allowed to copulate were also similar to controls. Corticosterone was lower than in males stressed for 50 days, but still higher than in controls. Testosterone in males stressed for 50 days and allowed to copulate was higher than in stressed

  14. Modernizing the MagIC Paleomagnetic and Rock Magnetic Database Technology Stack to Encourage Code Reuse and Reproducible Science

    NASA Astrophysics Data System (ADS)

    Minnett, R.; Koppers, A. A. P.; Jarboe, N.; Jonestrask, L.; Tauxe, L.; Constable, C.

    2016-12-01

    The Magnetics Information Consortium (https://earthref.org/MagIC/) develops and maintains a database and web application for supporting the paleo-, geo-, and rock magnetic scientific community. Historically, this objective has been met with an Oracle database and a Perl web application at the San Diego Supercomputer Center (SDSC). The Oracle Enterprise Cluster at SDSC, however, was decommissioned in July of 2016 and the cost for MagIC to continue using Oracle became prohibitive. This provided MagIC with a unique opportunity to reexamine the entire technology stack and data model. MagIC has developed an open-source web application using the Meteor (http://meteor.com) framework and a MongoDB database. The simplicity of the open-source full-stack framework that Meteor provides has improved MagIC's development pace and the increased flexibility of the data schema in MongoDB encouraged the reorganization of the MagIC Data Model. As a result of incorporating actively developed open-source projects into the technology stack, MagIC has benefited from their vibrant software development communities. This has translated into a more modern web application that has significantly improved the user experience for the paleo-, geo-, and rock magnetic scientific community.

  15. 19 CFR 10.2020 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 1 2014-04-01 2014-04-01 false Accessories, spare parts, or tools. 10.2020 Section 10.2020 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY... Trade Promotion Agreement Rules of Origin § 10.2020 Accessories, spare parts, or tools. (a) General...

  16. 19 CFR 10.600 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...-Central America-United States Free Trade Agreement Rules of Origin § 10.600 Accessories, spare parts, or... 10.600 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT... of the good's standard accessories, spare parts, or tools will be treated as originating goods if the...

  17. Accessory neuropathy after sternotomy: Clinico-anatomical correlation supporting an inflammatory cause.

    PubMed

    Kassem, Mohammad W; Iwanaga, Joe; Loukas, Marios; Stone, Jonathan J; Smith, Jay; Spinner, Robert J; Tubbs, R Shane

    2018-04-01

    Inflammatory etiologies are becoming increasingly recognized as explanations of some neuropathies, especially those occurring in the perioperative period. Although "brachial neuritis" is known to affect extraplexal nerves, accessory nerve palsy following median sternotomy has been attributed to stretch on the nerve. To better elucidate stretch as a potential cause, a cadaveric study was performed. Two patients who developed accessory nerve palsy following median sternotomy are presented to illustrate features consistent with the diagnosis of a perioperative inflammatory neuropathy. Five adult unembalmed cadavers underwent exposure of the bilateral accessory nerves in the posterior cervical triangle. A median sternotomy was performed and self-retaining retractors positioned. With the head in neutral, left rotation and right rotation, retractors were opened as during surgery while observing and recording any accessory nerve movements. The self-retaining sternal retractors were fully opened to a mean inter-blade distance of 13 cm. Regardless of head position, from the initial retractor click to maximal opening there was no gross movement of the accessory nerve on the left or right sides. Opening self-retaining sternal retractors does not appear to stretch the accessory nerve in the posterior cervical triangle. Based on our clinical experience and cadaveric results, we believe that inflammatory conditions, (i.e., idiopathic brachial plexitis) can involve the accessory nerve, and might be triggered by surgical procedures. Clin. Anat. 31:417-421, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  18. Wounds caused by contact with muzzle-lift relief ports (Mag-Na-Port).

    PubMed

    Rogers, D R; Shem, R J

    1992-12-01

    Fan-shaped stippled burns were produced on the skin when a revolver whose barrel had been modified by the Mag-Na-Port process was fired twice with the side of the muzzle in contact. A grazing wound was produced by one bullet, and an oblique entry was produced by the other. The characteristics of Mag-Na-Port wounds and test shots are described, and these are compared with test shots from two other higher power revolvers.

  19. 21 CFR 884.2660 - Fetal ultrasonic monitor and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal ultrasonic monitor and accessories. 884.2660... Devices § 884.2660 Fetal ultrasonic monitor and accessories. (a) Identification. A fetal ultrasonic monitor is a device designed to transmit and receive ultrasonic energy into and from the pregnant woman...

  20. [The pathology of salivary glands. Tumors of the salivary glands].

    PubMed

    Mahy, P; Reychler, H

    2006-01-01

    The management of benign and malignant neoplasms of the salivary glands requires precise knowledge of tumor histogenesis and classification as well as surgical skills. Pleomorphic adenoma and Whartin's tumor are the most frequent tumors in parotid glands while the probability for malignant tumors is higher in other glands, especially in sublingual and minor salivary glands. Those malignant salivary glands tumors are rare and necessitate multidisciplinar staging and management in close collaboration with the pathologist and the radiation oncologist.

  1. Next Generation HeliMag UXO Mapping Technology

    DTIC Science & Technology

    2010-01-01

    Ancillary instrumentation records aircraft height above ground and attitude. A fluxgate magnetometer is used to allow for aeromagnetic compensation of... Magnetometer System WWII World War II WAA wide area assessment ACKNOWLEDGEMENTS This Next Generation HeliMag Unexploded Ordnance (UXO) Mapping...for deployment of seven total-field magnetometers on a Kevlar reinforced boom mounted on a Bell 206L helicopter. The objectives of this

  2. Mag-seeding of rat bone marrow stromal cells into porous hydroxyapatite scaffolds for bone tissue engineering.

    PubMed

    Shimizu, Kazunori; Ito, Akira; Honda, Hiroyuki

    2007-09-01

    Bone tissue engineering has been investigated as an alternative strategy for autograft transplantation. In the process of tissue engineering, cell seeding into three-dimensional (3-D) scaffolds is the first step for constructing 3-D tissues. We have proposed a methodology of cell seeding into 3-D porous scaffolds using magnetic force and magnetite nanoparticles, which we term Mag-seeding. In this study, we applied this Mag-seeding technique to bone tissue engineering using bone marrow stromal cells (BMSCs) and 3-D hydroxyapatite (HA) scaffolds. BMSCs were magnetically labeled with our original magnetite cationic liposomes (MCLs) having a positive surface charge to improve adsorption to cell surface. Magnetically labeled BMSCs were seeded onto a scaffold, and a 1-T magnet was placed under the scaffold. By using Mag-seeding, the cells were successfully seeded into the internal space of scaffolds with a high cell density. The cell seeding efficiency into HA scaffolds by Mag-seeding was approximately threefold larger than that by static-seeding (conventional method, without a magnet). After a 14-d cultivation period using the osteogenic induction medium by Mag-seeding, the level of two representative osteogenic markers (alkaline phosphatase and osteocalcin) were significantly higher than those by static-seeding. These results indicated that Mag-seeding of BMSCs into HA scaffolds is an effective approach to bone tissue engineering.

  3. Accessory wandering spleen: Report of a case of laparoscopic approach in an asymptomatic patient

    PubMed Central

    Perin, Alessandro; Cola, Roberto; Favretti, Franco

    2014-01-01

    INTRODUCTION Accessory wandering spleen is a rare but dangerous condition. Abnormalities of the ligamentous apparatus of an accessory spleen may evolve into torsion of its vascular axis, which can lead to a splenic infarct making surgery necessary. Patients are often asymptomatic and the diagnosis can be accidental. An early diagnosis and a correct treatment are fundamental. PRESENTATION OF CASE In this case report a young woman underwent laparoscopic surgery after an incidental finding at a Pelvic Ultrasound of an accessory wandering spleen. DISCUSSION In literature are reported cases of asymptomatic patients with an accessory wandering spleen treated with a conservative approach. However, a torsion or infarct of the accessory wandering spleen leads to emergency surgery. The presence of an independent vascular axis of the accessory spleen reduces the risk of postoperative complications (e.g. thrombocytosis) and the administration of low molecular weight heparin should prevent the risk of portal thrombosis. CONCLUSION We suggest performing surgery with a laparoscopic approach in patients with accessory wandering spleen, though asymptomatic, because of the risk of serious complications in case of accessory spleen torsion. PMID:25460427

  4. Accessory breasts: a historical and current perspective.

    PubMed

    Loukas, Marios; Clarke, Pamela; Tubbs, R Shane

    2007-05-01

    The presence of accessory breast tissue such as extra nipples (polythelia) and extra breast (polymastia) is relatively common, with a high incidence of being misdiagnosed in clinical medicine. Although polythelia is congenital in origin and is identifiable at childhood, polymastia may not be evident until the influence of sex hormones during puberty. In this article, we present a review of the literature concerning the historical background of accessory breasts, their incidence, their misdiagnoses, and their association with other syndromes and diseases. Finally, we present the common treatment options available today for such conditions.

  5. Interaction of both plasmas in CO2 laser-MAG hybrid welding of carbon steel

    NASA Astrophysics Data System (ADS)

    Kutsuna, Muneharu; Chen, Liang

    2003-03-01

    Researches and developments of laser and arc hybrid welding has been curried out since in 1978. Especially, CO2 laser and TIG hybrid welding has been studied for increasing the penetration depth and welding speed. Recently laser and MIG/MAG/Plasma hybrid welding processes have been developed and applied to industries. It was recognized as a new welding process that promote the flexibility of the process for increasing the penetration depth, welding speed and allowable joint gap and improving the quality of the welds. In the present work, CO2 Laser-MAG hybrid welding of carbon steel (SM490) was investigated to make clear the phenomenon and characteristics of hybrid welding process comparing with laser welding and MAG process. The effects of many process parameters such as welding current, arc voltage, welding speed, defocusing distance, laser-to-arc distance on penetration depth, bead shape, spatter, arc stability and plasma formation were investigated in the present work. Especially, the interaction of laser plasma and MAG arc plasma was considered by changing the laser to arc distance (=DLA).

  6. Accessory proteins of SARS-CoV and other coronaviruses.

    PubMed

    Liu, Ding Xiang; Fung, To Sing; Chong, Kelvin Kian-Long; Shukla, Aditi; Hilgenfeld, Rolf

    2014-09-01

    The huge RNA genome of SARS coronavirus comprises a number of open reading frames that code for a total of eight accessory proteins. Although none of these are essential for virus replication, some appear to have a role in virus pathogenesis. Notably, some SARS-CoV accessory proteins have been shown to modulate the interferon signaling pathways and the production of pro-inflammatory cytokines. The structural information on these proteins is also limited, with only two (p7a and p9b) having their structures determined by X-ray crystallography. This review makes an attempt to summarize the published knowledge on SARS-CoV accessory proteins, with an emphasis on their involvement in virus-host interaction. The accessory proteins of other coronaviruses are also briefly discussed. This paper forms part of a series of invited articles in Antiviral Research on "From SARS to MERS: 10 years of research on highly pathogenic human coronaviruses" (see Introduction by Hilgenfeld and Peiris (2013)). Copyright © 2014 Elsevier B.V. All rights reserved.

  7. The benefits of using bluetooth accessories with hearing aids.

    PubMed

    Smith, Pauline; Davis, Adrian

    2014-10-01

    To investigate the benefits in reported outcomes after providing bluetooth accessories for established hearing aid users. Prospective observational study using validated quantitative outcome measures and detailed patient narrative before and two months after patients were provided with bluetooth accessories. Twelve patients with bilateral NHS hearing aids participated. They had a wide range of ages and hearing loss. After two months, 10 patients reported substantial additional benefit and kept the accessories; two returned them for various reasons. Statistically significant changes were seen in two validated outcome measures: the Glasgow Hearing Aid Benefit Profile and the International Outcome Inventory - Hearing Aids, but not in the Speech, Spatial and Qualities of Hearing Scale. Two notable benefits were reported: some described hearing the emotion and mood in a voice for the first time; others were amazed to report an improved ability to hear film or to hold conversations over the telephone. The provision of bluetooth accessories can give additional reported benefit for some patients - we need better knowledge about who benefits, and whether further support/training to individuals would make a difference.

  8. Crystallization of accessory phases in magmas by local saturation adjacent to phenocrysts

    USGS Publications Warehouse

    Bacon, C.R.

    1989-01-01

    Accessory minerals commonly occur attached to or included in the major crystalline phases of felsic and some intermediate igneous rocks. Apatite is particularly common as inclusions, but Fe-Ti oxides, pyrrhotite, zircon, monazite, chevkinite and xenotime are also known from silicic rocks. Accessories may nucleate near the host crystal/ liquid interface as a result of local saturation owing to formation of a differentiated chemical boundary layer in which accessory mineral solubility would be lower than in the surrounding liquid. Differentiation of this boundary layer would be greatest adjacent to ferromagnesian phenocrysts, especially Fe-Ti oxides; it is with oxides that accessories are most commonly associated in rocks. A boundary layer may develop if the crystal grows more rapidly than diffusion can transport incorporated and rejected elements to and from the phenocryst. Diffusion must dominate over convection as a mode of mass transfer near the advancing crystal/liquid interface in order for a boundary layer to exist. Accumulation of essential structural constituent elements of accessory minerals owing to their slow diffusion in evolved silicate melt also may force local saturation, but this is not a process that applies to all cases. Local saturation is an attractive mechanism for enhancing fractionation during crystallization differentiation. If accessory minerals attached to or included in phenocrysts formed because of local saturation, their host phenocrysts must have grown rapidly when accessories nucleated in comparison to lifetimes of magma reservoirs. Some inconsistencies remain in a local saturation origin for accessory phases that cannot be evaluated without additional information. ?? 1989.

  9. TetraMag: A compact magnetizing device based on eight rotating permanent magnets

    NASA Astrophysics Data System (ADS)

    Gilbert, M.; Mertins, H.-Ch.; Tesch, M.; Berges, O.; Feilbach, Herbert; Schneider, C. M.

    2012-02-01

    In this paper we describe a novel magnetizing device based on eight rotatable permanent magnets arranged in a quadrupolar configuration, which is termed the TetraMag. TetraMag creates stable and homogeneous magnetic fields at the sample position with a resolution of 0.02 mT tunable between -570 mT and +570 mT. The field direction is continuously rotatable between 0° and 360° within the sample plane, while the field strength is maintained. A simplified mathematical description of TetraMag is developed leading to magnetic field calculations which are in good agreement with the experimental results. This versatile device avoids electrical energy dissipation, cooling mechanisms, and hysteresis effects known from classical electromagnets. It is ultrahigh vacuum compatible and it offers a completely free optical path over 180° for magneto-optical experiments. It is suitable for scattering experiments with synchrotron radiation and neutrons and may be employed in a large class of magnetization experiments.

  10. 26 CFR 48.4061(b)-3 - Rebuilt, reconditioned, or repaired parts or accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., reconditioned, or repaired parts or accessories. (a) Rebuilt parts or accessories. Rebuilding of automobile... for the person reassembling the generator, (6) reground or remetalized crankshafts, and (7) engines in... reassembling (with any necessary replacements of worn parts) of automobile parts or accessories, such as fuel...

  11. 26 CFR 48.4061(b)-3 - Rebuilt, reconditioned, or repaired parts or accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., reconditioned, or repaired parts or accessories. (a) Rebuilt parts or accessories. Rebuilding of automobile... for the person reassembling the generator, (6) reground or remetalized crankshafts, and (7) engines in... reassembling (with any necessary replacements of worn parts) of automobile parts or accessories, such as fuel...

  12. 26 CFR 48.4061(b)-3 - Rebuilt, reconditioned, or repaired parts or accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., reconditioned, or repaired parts or accessories. (a) Rebuilt parts or accessories. Rebuilding of automobile... for the person reassembling the generator, (6) reground or remetalized crankshafts, and (7) engines in... reassembling (with any necessary replacements of worn parts) of automobile parts or accessories, such as fuel...

  13. 14 CFR 221.52 - Airport to airport application, accessorial services.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false Airport to airport application, accessorial... Charges § 221.52 Airport to airport application, accessorial services. Tariffs shall specify whether or not the fares therein include services in addition to airport-to-airport transportation. ...

  14. 14 CFR 221.52 - Airport to airport application, accessorial services.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false Airport to airport application, accessorial... Charges § 221.52 Airport to airport application, accessorial services. Tariffs shall specify whether or not the fares therein include services in addition to airport-to-airport transportation. ...

  15. 14 CFR 221.52 - Airport to airport application, accessorial services.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Airport to airport application, accessorial... Charges § 221.52 Airport to airport application, accessorial services. Tariffs shall specify whether or not the fares therein include services in addition to airport-to-airport transportation. ...

  16. 14 CFR 221.52 - Airport to airport application, accessorial services.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 4 2012-01-01 2012-01-01 false Airport to airport application, accessorial... Charges § 221.52 Airport to airport application, accessorial services. Tariffs shall specify whether or not the fares therein include services in addition to airport-to-airport transportation. ...

  17. 14 CFR 221.52 - Airport to airport application, accessorial services.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Airport to airport application, accessorial... Charges § 221.52 Airport to airport application, accessorial services. Tariffs shall specify whether or not the fares therein include services in addition to airport-to-airport transportation. ...

  18. Migration to Current Open Source Technologies by MagIC Enables a More Responsive Website, Quicker Development Times, and Increased Community Engagement

    NASA Astrophysics Data System (ADS)

    Jarboe, N.; Minnett, R.; Koppers, A.; Constable, C.; Tauxe, L.; Jonestrask, L.

    2017-12-01

    The Magnetics Information Consortium (MagIC) supports an online database for the paleo, geo, and rock magnetic communities ( https://earthref.org/MagIC ). Researchers can upload data into the archive and download data as selected with a sophisticated search system. MagIC has completed the transition from an Oracle backed, Perl based, server oriented website to an ElasticSearch backed, Meteor based thick client website technology stack. Using JavaScript on both the sever and the client enables increased code reuse and allows easy offloading many computational operations to the client for faster response. On-the-fly data validation, column header suggestion, and spreadsheet online editing are some new features available with the new system. The 3.0 data model, method codes, and vocabulary lists can be browsed via the MagIC website and more easily updated. Source code for MagIC is publicly available on GitHub ( https://github.com/earthref/MagIC ). The MagIC file format is natively compatible with the PmagPy ( https://github.com/PmagPy/PmagPy) paleomagnetic analysis software. MagIC files can now be downloaded from the database and viewed and interpreted in the PmagPy GUI based tool, pmag_gui. Changes or interpretations of the data can then be saved by pmag_gui in the MagIC 3.0 data format and easily uploaded to the MagIC database. The rate of new contributions to the database has been increasing with many labs contributing measurement level data for the first time in the last year. Over a dozen file format conversion scripts are available for translating non-MagIC measurement data files into the MagIC format for easy uploading. We will continue to work with more labs until the whole community has a manageable workflow for contributing their measurement level data. MagIC will continue to provide a global repository for archiving and retrieving paleomagnetic and rock magnetic data and, with the new system in place, be able to more quickly respond to the community

  19. Accessory mineral records of tectonic environments? (Invited)

    NASA Astrophysics Data System (ADS)

    Storey, C.; Marschall, H. R.; Enea, F.; Taylor, J.; Jennings, E. S.

    2010-12-01

    Accessory mineral research continues to gather momentum as we seek to unleash their full potential. It is now widely recognised that robust accessory minerals, such as zircon, rutile, titanite, allanite and monazite, are archives of important trace elements that can help deduce metamorphic reaction history in metapelites, metabasites and other rock types. Moreover, they are important carriers of certain trace elements and govern or influence the products of partial melting and of fluid-rock interaction (e.g. magmas and mineralisation) in settings like subduction zones and hydrothermal systems. Perhaps most importantly, they can often be dated using the U-Th-Pb system. More recently, radiogenic (Lu-Hf, Sm-Nd, Rb-Sr) and stable (O) isotope systems have been applied and have further pushed the utility of accessory mineral research. In this talk I will discuss some of these advances towards one particular aim: the use of detrital accessory minerals for fingerprinting tectonic environments. This is a particularly laudable aim in Precambrian rocks, for which the preservation potential of orogenic belts and fossil subduction zones and their diagnostic metamorphic rocks is low. The implication is that our understanding of plate tectonics, particularly in the Archaean, is biased by the preserved in-tact rock record. An analogy is that Jack Hills zircons record evidence of Earth’s crust some 400 Ma before the preserved rock record begins. I will focus on some recent advances and new data from rutile and also the mineral inclusion record within zircon, which shows great promise for petrologic interpretation.

  20. Accessory Devices Frequently Used for Endoscopic Submucosal Dissection

    PubMed Central

    Choi, Hyuk Soon; Chun, Hoon Jai

    2017-01-01

    Endoscopic submucosal dissection (ESD) is increasingly being considered an essential component of treatment for early gastrointestinal cancers and subepithelial tumors. The ESD technique owes its popularity to the development of sophisticated instruments used for ESD. With an increase in the number of ESD procedures performed, there is rapid development in the number and types of endoscopic accessory devices used for such procedures. Despite the large numbers of new devices developed and marketed, the use of ESD instruments and accessory devices is largely determined by individual preferences and experiences. Accessory devices frequently used during ESD are important tools for ESD techniques. Each instrument possesses characteristic advantages and disadvantages associated with its use, and no one instrument is superior in all respects to others. In this article, we review the characteristics of endoscopic electrical knives, cap and hood, and hemostatic devices commonly used in ESD. PMID:28609818

  1. 21 CFR 884.1300 - Uterotubal carbon dioxide insufflator and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Uterotubal carbon dioxide insufflator and... Gynecological Diagnostic Devices § 884.1300 Uterotubal carbon dioxide insufflator and accessories. (a) Identification. A uterotubal carbon dioxide insufflator and accessories is a device used to test the patency...

  2. 21 CFR 884.1300 - Uterotubal carbon dioxide insufflator and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Uterotubal carbon dioxide insufflator and... Gynecological Diagnostic Devices § 884.1300 Uterotubal carbon dioxide insufflator and accessories. (a) Identification. A uterotubal carbon dioxide insufflator and accessories is a device used to test the patency...

  3. 21 CFR 884.1300 - Uterotubal carbon dioxide insufflator and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Uterotubal carbon dioxide insufflator and... Gynecological Diagnostic Devices § 884.1300 Uterotubal carbon dioxide insufflator and accessories. (a) Identification. A uterotubal carbon dioxide insufflator and accessories is a device used to test the patency...

  4. 21 CFR 888.5850 - Nonpowered orthopedic traction apparatus and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonpowered orthopedic traction apparatus and accessories. 888.5850 Section 888.5850 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... orthopedic traction apparatus and accessories. (a) Identification. A nonpowered orthopedic traction apparatus...

  5. 21 CFR 888.5850 - Nonpowered orthopedic traction apparatus and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nonpowered orthopedic traction apparatus and accessories. 888.5850 Section 888.5850 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... orthopedic traction apparatus and accessories. (a) Identification. A nonpowered orthopedic traction apparatus...

  6. Tissue-Specific Transcriptomics in the Field Cricket Teleogryllus oceanicus

    PubMed Central

    Bailey, Nathan W.; Veltsos, Paris; Tan, Yew-Foon; Millar, A. Harvey; Ritchie, Michael G.; Simmons, Leigh W.

    2013-01-01

    Field crickets (family Gryllidae) frequently are used in studies of behavioral genetics, sexual selection, and sexual conflict, but there have been no studies of transcriptomic differences among different tissue types. We evaluated transcriptome variation among testis, accessory gland, and the remaining whole-body preparations from males of the field cricket, Teleogryllus oceanicus. Non-normalized cDNA libraries from each tissue were sequenced on the Roche 454 platform, and a master assembly was constructed using testis, accessory gland, and whole-body preparations. A total of 940,200 reads were assembled into 41,962 contigs, to which 36,856 singletons (reads not assembled into a contig) were added to provide a total of 78,818 sequences used in annotation analysis. A total of 59,072 sequences (75%) were unique to one of the three tissues. Testis tissue had the greatest proportion of tissue-specific sequences (62.6%), followed by general body (56.43%) and accessory gland tissue (44.16%). We tested the hypothesis that tissues expressing gene products expected to evolve rapidly as a result of sexual selection—testis and accessory gland—would yield a smaller proportion of BLASTx matches to homologous genes in the model organism Drosophila melanogaster compared with whole-body tissue. Uniquely expressed sequences in both testis and accessory gland showed a significantly lower rate of matching to annotated D. melanogaster genes compared with those from general body tissue. These results correspond with empirical evidence that genes expressed in testis and accessory gland tissue are rapidly evolving targets of selection. PMID:23390599

  7. Accessory costs of seed production and the evolution of angiosperms.

    PubMed

    Lord, Janice M; Westoby, Mark

    2012-01-01

    Accessory costs of reproduction frequently equal or exceed direct investment in offspring, and can limit the evolution of small offspring sizes. Early angiosperms had minimum seed sizes, an order of magnitude smaller than their contemporaries. It has been proposed that changes to reproductive features at the base of the angiosperm clade reduced accessory costs thus removing the fitness disadvantage of small seeds. We measured accessory costs of reproduction in 25 extant gymnosperms and angiosperms, to test whether angiosperms can produce small seeds more economically than gymnosperms. Total accessory costs scaled isometrically to seed mass for angiosperms but less than isometrically for gymnosperms, so that smaller seeds were proportionally more expensive for gymnosperms to produce. In particular, costs of abortions and packaging structures were significantly higher in gymnosperms. Also, the relationship between seed:ovule ratio and seed size was negative in angiosperms but positive in gymnosperms. We argue that the carpel was a key evolutionary innovation reducing accessory costs in angiosperms by allowing sporophytic control of pre- and postzygotic mate selection and timing of resource allocation. The resulting reduction in costs of aborting unfertilized ovules or genetically inferior embryos would have lowered total reproductive costs enabling early angiosperms to evolve small seed sizes and short generation times. © 2011 The Author(s). Evolution © 2011 The Society for the Study of Evolution.

  8. [Evaluation of iatrogenic accessory nerve injury in forensic medical practice].

    PubMed

    Somogyi, E; Irányi, J

    1996-04-14

    The authors give a survey of the clinical and medical-legal characteristics of the accessory nerve injury. In the past two decades the conception of the successfulness of the surgical treatment of the accessory nerve injury became prevailing. About the medical-legal aspects of the iatrogenic injury of the nerve reported in connection of the reconstructive surgery chiefly also departments of neurosurgery, orthopedics and traumatology. In the case of the authors a 70 year old patient suffered 10 years ago a iatrogenic accessory nerve injury. The mild trapezius palsy recovered spontaneously practically with cosmetic disadvantage. In connection with the development of extreme dorso-lumbal scoliosis associated with torsion the trapezius atrophy worsened. Physical therapy was partly successful. But the patient became unfit for manual work. Their observations sustain the data of authors who established that in the case of accessory nerve injury not only the surgical but also conservative treatment is usually successful. In opposite to certain data of the literature the authors establish that the iatrogenic injuries of the accessory nerve may lead to significant lifelong disability. The diagnosis is not always made in time with consequent delay in repair. This may be regarded as an unfavorable issue during medical-legal discussions. The authors recommend in interest to prevent nerve injury in the posterior triangle of the neck to perform operation in special department.

  9. Rhabdovirus accessory genes.

    PubMed

    Walker, Peter J; Dietzgen, Ralf G; Joubert, D Albert; Blasdell, Kim R

    2011-12-01

    The Rhabdoviridae is one of the most ecologically diverse families of RNA viruses with members infecting a wide range of organisms including placental mammals, marsupials, birds, reptiles, fish, insects and plants. The availability of complete nucleotide sequences for an increasing number of rhabdoviruses has revealed that their ecological diversity is reflected in the diversity and complexity of their genomes. The five canonical rhabdovirus structural protein genes (N, P, M, G and L) that are shared by all rhabdoviruses are overprinted, overlapped and interspersed with a multitude of novel and diverse accessory genes. Although not essential for replication in cell culture, several of these genes have been shown to have roles associated with pathogenesis and apoptosis in animals, and cell-to-cell movement in plants. Others appear to be secreted or have the characteristics of membrane-anchored glycoproteins or viroporins. However, most encode proteins of unknown function that are unrelated to any other known proteins. Understanding the roles of these accessory genes and the strategies by which rhabdoviruses use them to engage, divert and re-direct cellular processes will not only present opportunities to develop new anti-viral therapies but may also reveal aspects of cellar function that have broader significance in biology, agriculture and medicine. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  10. [Improvement in nuclear medicine diagnosis of kidney function using 99m technetium mercaptoacetyltriglycine (MAG3)].

    PubMed

    Erpenbach, K; Ebert, A; Wieler, H

    1991-03-01

    Renal scintigraphy and clearance measurement are indispensable in nephro-urologic disorders. A continuous series of 103 sequential scintigraphies and clearance measurements were performed with the new technetium-labelled agent MAG3 (Gamma-kamera, Phillips Tomo Diagnost) and 131I-orthohippuric acid (OIH) using the Oberhausen method (Nucleopan, Siemens). The time-activity curves obtained with the two radionuclides agreed exactly. Reaching a tubular excretion rate of nearly 90%, the clearance of MAG3 differed by no more than 6% from the OIH clearance in 95% of the cases. The factor between clearances of the two radionuclides was determined by means of a commercially available software according to the Oberhausen method and amounted to 0.59 +/- 0.09. The favorable physical properties and high activity of MAG3 permit exact examination of tubular function and better assessment of renal morphology than hippuran-labelled radionuclides. The low radiation dose combined with a better spatial resolution, especially, the constant availability in a nuclear medicine department should give the preference to MAG3.

  11. Ancestor of land plants acquired the DNA-3-methyladenine glycosylase (MAG) gene from bacteria through horizontal gene transfer.

    PubMed

    Fang, Huimin; Huangfu, Liexiang; Chen, Rujia; Li, Pengcheng; Xu, Shuhui; Zhang, Enying; Cao, Wei; Liu, Li; Yao, Youli; Liang, Guohua; Xu, Chenwu; Zhou, Yong; Yang, Zefeng

    2017-08-24

    The origin and evolution of land plants was an important event in the history of life and initiated the establishment of modern terrestrial ecosystems. From water to terrestrial environments, plants needed to overcome the enhanced ultraviolet (UV) radiation and many other DNA-damaging agents. Evolving new genes with the function of DNA repair is critical for the origin and radiation of land plants. In bacteria, the DNA-3-methyladenine glycosylase (MAG) recognizes of a variety of base lesions and initiates the process of the base excision repair for damaged DNA. The homologs of MAG gene are present in all major lineages of streptophytes, and both the phylogenic and sequence similarity analyses revealed that green plant MAG gene originated through an ancient horizontal gene transfer (HGT) event from bacteria. Experimental evidence demonstrated that the expression of the maize ZmMAG gene was induced by UV and zeocin, both of which are known as DNA-damaging agents. Further investigation revealed that Streptophyta MAG genes had undergone positive selection during the initial evolutionary period in the ancestor of land plants. Our findings demonstrated that the ancient HGT of MAG to the ancestor of land plants probably played an important role in preadaptation to DNA-damaging agents in terrestrial environments.

  12. Simon Effect with and without Awareness of the Accessory Stimulus

    ERIC Educational Resources Information Center

    Treccani, Barbara; Umilta, Carlo; Tagliabue, Mariaelena

    2006-01-01

    The authors investigated whether a Simon effect could be observed in an accessory-stimulus Simon task when participants were unaware of the task-irrelevant accessory cue. In Experiment 1A a central visual target was accompanied by a suprathreshold visual lateral cue. A regular Simon effect (i.e., faster cue-response corresponding reaction times…

  13. Visual and auditory accessory stimulus offset and the Simon effect.

    PubMed

    Nishimura, Akio; Yokosawa, Kazuhiko

    2010-10-01

    We investigated the effect on the right and left responses of the disappearance of a task-irrelevant stimulus located on the right or left side. Participants pressed a right or left response key on the basis of the color of a centrally located visual target. Visual (Experiment 1) or auditory (Experiment 2) task-irrelevant accessory stimuli appeared or disappeared at locations to the right or left of the central target. In Experiment 1, responses were faster when onset or offset of the visual accessory stimulus was spatially congruent with the response. In Experiment 2, responses were again faster when onset of the auditory accessory stimulus and the response were on the same side. However, responses were slightly slower when offset of the auditory accessory stimulus and the response were on the same side than when they were on opposite sides. These findings indicate that transient change information is crucial for a visual Simon effect, whereas sustained stimulation from an ongoing stimulus also contributes to an auditory Simon effect.

  14. Mycoplasma agalactiae MAG_5040 is a Mg2+-Dependent, Sugar-Nonspecific SNase Recognised by the Host Humoral Response during Natural Infection

    PubMed Central

    Cacciotto, Carla; Addis, Maria Filippa; Coradduzza, Elisabetta; Carcangiu, Laura; Nuvoli, Anna Maria; Tore, Gessica; Dore, Gian Mario; Pagnozzi, Daniela; Uzzau, Sergio; Chessa, Bernardo; Pittau, Marco; Alberti, Alberto

    2013-01-01

    In this study the enzymatic activity of Mycoplasma agalactiae MAG_5040, a magnesium-dependent nuclease homologue to the staphylococcal SNase was characterized and its antigenicity during natural infections was established. A UGA corrected version of MAG_5040, lacking the region encoding the signal peptide, was expressed in Escherichia coli as a GST fusion protein. Recombinant GST-MAG_5040 exhibits nuclease activity similar to typical sugar-nonspecific endo- and exonucleases, with DNA as the preferred substrate and optimal activity in the presence of 20 mM MgCl2 at temperatures ranging from 37 to 45°C. According to in silico analyses, the position of the gene encoding MAG_5040 is consistently located upstream an ABC transporter, in most sequenced mycoplasmas belonging to the Mycoplasma hominis group. In M. agalactiae, MAG_5040 is transcribed in a polycistronic RNA together with the ABC transporter components and with MAG_5030, which is predicted to be a sugar solute binding protein by 3D modeling and homology search. In a natural model of sheep and goats infection, anti-MAG_5040 antibodies were detected up to 9 months post infection. Taking into account its enzymatic activity, MAG_5040 could play a key role in Mycoplasma agalactiae survival into the host, contributing to host pathogenicity. The identification of MAG_5040 opens new perspectives for the development of suitable tools for the control of contagious agalactia in small ruminants. PMID:23469065

  15. Interdisciplinary Collaboration amongst Colleagues and between Initiatives with the Magnetics Information Consortium (MagIC) Database

    NASA Astrophysics Data System (ADS)

    Minnett, R.; Koppers, A. A. P.; Jarboe, N.; Tauxe, L.; Constable, C.; Jonestrask, L.; Shaar, R.

    2014-12-01

    Earth science grand challenges often require interdisciplinary and geographically distributed scientific collaboration to make significant progress. However, this organic collaboration between researchers, educators, and students only flourishes with the reduction or elimination of technological barriers. The Magnetics Information Consortium (http://earthref.org/MagIC/) is a grass-roots cyberinfrastructure effort envisioned by the geo-, paleo-, and rock magnetic scientific community to archive their wealth of peer-reviewed raw data and interpretations from studies on natural and synthetic samples. MagIC is dedicated to facilitating scientific progress towards several highly multidisciplinary grand challenges and the MagIC Database team is currently beta testing a new MagIC Search Interface and API designed to be flexible enough for the incorporation of large heterogeneous datasets and for horizontal scalability to tens of millions of records and hundreds of requests per second. In an effort to reduce the barriers to effective collaboration, the search interface includes a simplified data model and upload procedure, support for online editing of datasets amongst team members, commenting by reviewers and colleagues, and automated contribution workflows and data retrieval through the API. This web application has been designed to generalize to other databases in MagIC's umbrella website (EarthRef.org) so the Geochemical Earth Reference Model (http://earthref.org/GERM/) portal, Seamount Biogeosciences Network (http://earthref.org/SBN/), EarthRef Digital Archive (http://earthref.org/ERDA/) and EarthRef Reference Database (http://earthref.org/ERR/) will benefit from its development.

  16. 21 CFR 878.4400 - Electrosurgical cutting and coagulation device and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrosurgical cutting and coagulation device and....4400 Electrosurgical cutting and coagulation device and accessories. (a) Identification. An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control...

  17. MERS-CoV Accessory ORFs Play Key Role for Infection and Pathogenesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Menachery, Vineet D.; Mitchell, Hugh D.; Cockrell, Adam S.

    ABSTRACT While dispensable for viral replication, coronavirus (CoV) accessory open reading frame (ORF) proteins often play critical roles during infection and pathogenesis. Utilizing a previously generated mutant, we demonstrate that the absence of all four Middle East respiratory syndrome CoV (MERS-CoV) accessory ORFs (deletion of ORF3, -4a, -4b, and -5 [dORF3-5]) has major implications for viral replication and pathogenesis. Importantly, attenuation of the dORF3-5 mutant is primarily driven by dysregulated host responses, including disrupted cell processes, augmented interferon (IFN) pathway activation, and robust inflammation.In vitroreplication attenuation also extends toin vivomodels, allowing use of dORF3-5 as a live attenuated vaccine platform.more » Finally, examination of ORF5 implicates a partial role in modulation of NF-κB-mediated inflammation. Together, the results demonstrate the importance of MERS-CoV accessory ORFs for pathogenesis and highlight them as potential targets for surveillance and therapeutic treatments moving forward. IMPORTANCEThe initial emergence and periodic outbreaks of MERS-CoV highlight a continuing threat posed by zoonotic pathogens to global public health. In these studies, mutant virus generation demonstrates the necessity of accessory ORFs in regard to MERS-CoV infection and pathogenesis. With this in mind, accessory ORF functions can be targeted for both therapeutic and vaccine treatments in response to MERS-CoV and related group 2C coronaviruses. In addition, disruption of accessory ORFs in parallel may offer a rapid response platform to attenuation of future emergent strains based on both SARS- and MERS-CoV accessory ORF mutants.« less

  18. Spectroscopic Analysis of 10MAG/LDAO Reverse Micelles to Determine Characteristic Properties and Behavioral Extrema

    NASA Astrophysics Data System (ADS)

    Berg, Joshua; Mawson, Cara; Norris, Zach; Nucci, Nathaniel

    Reverse micelles are spontaneously organizing complexes of surfactant that encapsulate a nanoscale pool of water in a bulk non-polar solvent. Reverse micelle (RM) mixtures have a wide range of applications, including biophysical investigation of protein systems. A new RM mixture composed of decyl-1-monoglycerol (10MAG) and lauryldimethylammonium-N-oxide (LDAO) was recently described. This mixture has the potential to prove more widely applicable for use of RMs in applications that involve encapsulation of macromolecules, yet little is known about the phase behavior or size of reverse micelles created by this mixture. Data describing such behaviors for this mixture are presented here. We have used dynamic light scattering (DLS) and fluorescence spectroscopy to investigate the size and partitioning behavior of RMs in varying mixtures of 10MAG, LDAO, water, pentane, and hexanol. These data demonstrate that the 10MAG/LDAO RM mixture exhibits markedly different phase and RM size behavior than that of commonly used RM surfactant mixtures. The implications of these findings for use of the 10MAG/LDAO mix for RM applications will also be addressed. Funding provided by Rowan University.

  19. Electrophysiology of Cranial Nerve Testing: Spinal Accessory and Hypoglossal Nerves.

    PubMed

    Stino, Amro M; Smith, Benn E

    2018-01-01

    Multiple techniques have been developed for the electrodiagnostic evaluation of cranial nerves XI and XII. Each of these carries both benefits and limitations, with more techniques and data being available in the literature for spinal accessory than hypoglossal nerve evaluation. Spinal accessory and hypoglossal neuropathy are relatively uncommon cranial mononeuropathies that may be evaluated in the outpatient electrodiagnostic laboratory setting. A review of available literature using PubMed was conducted regarding electrodiagnostic technique in the evaluation of spinal accessory and hypoglossal nerves searching for both routine nerve conduction studies and repetitive nerve conduction studies. The review provided herein provides a resource by which clinical neurophysiologists may develop and implement clinical and research protocols for the evaluation of both of these lower cranial nerves in the outpatient setting.

  20. MAG traffic generator study : survey data from Arizona State University

    DOT National Transportation Integrated Search

    1994-12-01

    The Maricopa Association of Governments (MAG) is responsible for the travel demand models used to forecast multi-modal travel behavior in the Phoenix metropolitan area. The main campus of Arizona State University (ASU), located in Tempe, is one of th...

  1. 76 FR 46330 - NUREG-1934, Nuclear Power Plant Fire Modeling Application Guide (NPP FIRE MAG); Second Draft...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-02

    ... NUCLEAR REGULATORY COMMISSION [NRC-2009-0568] NUREG-1934, Nuclear Power Plant Fire Modeling Application Guide (NPP FIRE MAG); Second Draft Report for Comment AGENCY: Nuclear Regulatory Commission... 1023259), ``Nuclear Power Plant Fire Modeling Application Guide (NPP FIRE MAG), Second Draft Report for...

  2. Magnetically Responsive Optical Nanoprobes (MagRONs) and Systems

    DTIC Science & Technology

    2004-02-28

    5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER The regents of the University of...research. MagMOON Architechtures I Controlled deposition of magnetic materials onto any nanosensor Prism coated nanoparticles Electric field sensors...into a predefined pattern has been the focus of many investigations.[7-11] For example, strawberry-like composite materials using organic -inorganic

  3. Teaching Techniques for Accessory Percussion

    ERIC Educational Resources Information Center

    Micallef, Ken

    2007-01-01

    Everyone is familiar with the main percussion instruments of the contemporary orchestra: bass drum, snare drum, suspended cymbal, vibraphone, and timpani. But as source material broadens, so do the demands placed on the percussion section. Accessory, or auxiliary percussion, can make the difference between a typical rendition of a well-known piece…

  4. Two novel elements (CFG1 and PYG1) of Mag lineage of Ty3/Gypsy retrotransposons from Zhikong scallop (Chlamys farreri) and Japanese scallop (Patinopecten yessoensis).

    PubMed

    Wang, Shi; Bao, Zhenmin; Hu, Xiaoli; Shao, Mingyu; Zhang, Lingling; Hu, Jingjie

    2008-05-01

    Two novel elements (CFG1 and PYG1) of Mag lineage of Ty3/Gypsy retrotransposons were cloned from Zhikong scallop (Chlamys farreri) and Japanese scallop (Patinopecten yessoensis). The total length of the CFG1 element is 4826 bp, including 5'-LTR (192 bp), the entire ORF (4047 bp) and 3'-LTR (189 bp). The entire ORFs of both CFG1 and PYG1 elements are composed of 1348 aa and do not have any frameshifts. Their closest relative is Jule element from the poeciliid fish (Xiphophorus maculatus). On average, the diploid genome of C. farreri contains approximately 84 copies of CFG1 elements. We summarize the major features of CFG1, PYG1 and other elements of Mag lineage of the Ty3/Gypsy group. mRNA expression of CFG1 element in larvae increases gradually before the gastrulae stage and decreases gradually afterward, whereas in adductor such expression in adductor muscle and digestive gland are lower than those in other tissues. Overall, mRNA expression of CFG1 element in the early larvae is significantly higher than that in adult tissues. In muscle tissue, while the promoter and partial GAG domain of CFG1 element are unmethylated, the partial RT domain is highly methylated. These results suggest that CFG1 expression may be controlled by a post-transcriptional gene silencing mechanism that is associated with coding-region (RT domain) methylation.

  5. Accessory renal arteries: Prevalence in resistant hypertension and an important role in nonresponse to radiofrequency renal denervation.

    PubMed

    VonAchen, Paige; Hamann, Jason; Houghland, Thomas; Lesser, John R; Wang, Yale; Caye, David; Rosenthal, Kristi; Garberich, Ross F; Daniels, Mary; Schwartz, Robert S

    The aim of this study was to understand the role of accessory renal arteries in resistant hypertension, and to establish their role in nonresponse to radiofrequency renal denervation (RDN) procedures. Prior studies suggest a role for accessory renal arteries in hypertensive syndromes, and recent clinical trials of renal denervation report that these anomalies are highly prevalent in resistant hypertension. This study evaluated the relationships among resistant hypertension, accessory renal arteries, and the response to radiofrequency (RF) renal denervation. Computed Tomography Angiography (CTA) and magnetic resonance imaging (MRI) scans from 58 patients with resistant hypertension undergoing RF renal denervation (RDN) were evaluated. Results were compared with CT scans in 57 healthy, normotensive subjects undergoing screening as possible renal transplant donors. All scans were carefully studied for accessory renal arteries, and were correlated with long term blood pressure reduction. Accessory renal arteries were markedly more prevalent in the hypertensive patients than normotensive renal donors (59% vs 32% respectively, p=0.004). RDN had an overall nonresponse rate of 29% (response rate 71%). Patients without accessory vessels had a borderline higher response rate to RDN than those with at least one accessory vessel (83% vs 62% respectively, p=0.076) and a higher RDN response than patients with untreated accessory arteries (83% vs 55%; p=0.040). For accessory renal arteries and nonresponse, the sensitivity was 76%, specificity 49%, with positive and negative predictive values 38% and 83% respectively. Accessory renal arteries were markedly over-represented in resistant hypertensives compared with healthy controls. While not all patients with accessory arteries were nonresponders, nonresponse was related to both the presence and non-treatment of accessory arteries. Addressing accessory renal arteries in future clinical trials may improve RDN therapeutic efficacy

  6. The Effect of External Magnetic Fields on the MRT Instability in MagLIF

    NASA Astrophysics Data System (ADS)

    Hess, Mark; Peterson, Kyle; Weis, Matthew; Lau, Yue Ying

    2014-10-01

    Recent experiments on MagLIF which incorporate an external B-field suggest that the MRT instability within the liner has a different behavior than without the B-field. Previous work by Chandrasekhar and Harris have illustrated how the MRT growth rate, assuming fixed liner density and fixed acceleration, can change due to the presence of an external B-field. In this work, we show how the growth rate of the MRT instability is dynamically affected by the rapidly varying acceleration, liner density, and surface magnetic field, which is composed of the external B-field and the drive B-field of the liner in the MagLIF experiments. In addition, we also examine the effects of finite liner resistivity on MRT growth, which gives rise to an additional time scale corresponding to magnetic diffusion. We discuss the implications of this result for future MagLIF designs. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under Contract DE-AC04-94AL85000.

  7. Clinical outcome of surgical treatment of the symptomatic accessory navicular.

    PubMed

    Kopp, Franz J; Marcus, Randall E

    2004-01-01

    When conservative treatment fails to provide relief for a symptomatic accessory navicular, surgical intervention may be necessary. Numerous studies have been published, reporting the results of the traditional Kidner procedure and alternative surgical techniques, all of which produce mostly satisfactory clinical outcomes. The purpose of this study was to report the clinical results, utilizing the American Orthopaedic Foot and Ankle Society (AOFAS) Midfoot Scale, of surgical management for symptomatic accessory navicular with simple excision and anatomic repair of the tibialis posterior tendon. The authors retrospectively reviewed the results of 13 consecutive patients (14 feet) who underwent surgical treatment for symptomatic accessory navicular. The patients ranged in age from 16 to 64 years (average, 34.1 years; mean, 28.2 years) at the time of surgery. All patients had a type II accessory navicular. The average follow-up of the patients involved in the study was 103.4 months (range, 45-194 months). The AOFAS Midfoot Scale was utilized to determine both preoperative and postoperative clinical status of the 14 feet included in the study. The average preoperative AOFAS score was 48.2 (range, 20-75; mean, 38.8). The average postoperative AOFAS score was 94.5 (range, 83-100; mean, 94.3). At last follow-up, 13 of 14 feet were without any pain, no patients had activity limitations, and only two of 14 feet required shoe insert modification. Postoperatively, no patients had a clinically notable change in their preoperative midfoot longitudinal arch alignment. All of the patients in the study were satisfied with the outcome of their surgery and would undergo the same operation again under similar circumstances. When conservative measures fail to relieve the symptoms of a painful accessory navicular, simple excision of the accessory navicular and anatomic repair of the posterior tibialis tendon is a successful intervention. Overall, the procedure provides reliable pain

  8. Immunohistochemical sweat gland profiles.

    PubMed

    Noël, Fanchon; Piérard, Gérald E; Delvenne, Philippe; Quatresooz, Pascale; Humbert, Philippe; Piérard-Franchimont, Claudine

    2013-09-01

    Human sweat glands are heterogeneous in their structures and functions. Accordingly, eccrine, apocrine, and apoeccrine glands are distinguished. Some immunohistochemical markers are expected to distinguish the sweat gland types in their secretory and excretory parts. This study used two sets of antibodies. The first panel was composed of antibodies directed to well-defined sweat gland structures. The molecular targets included the low-molecular-weight cytokeratins CAM 5.2, the S100-B protein, the epithelial membrane antigen (EMA), the carcinoembryonic antigen (CEA), and the lectin Ulex europaeus agglutinin-1 (UEA-1). A second exploratory panel of antibodies targeted syndecan-1 (CD138), NKI-C3 (CD63), and CD68. They were used to disclose some undescribed antigen expressions in human sweat glands. The first set of antibodies confirmed previous findings. The immunoreactivities of the three sweat gland types were similar in the excretory ducts. By contrast, they were distinguished in the deeper coiled secretory portions of the glands. Clues supporting their distinction and probably their functional activity were obtained by immunohistochemistry using the S100-B protein, CEA and CD63 antibodies. The immunoreactivity to the S100-B protein, CEA and CD63 possibly help identifying apoeccrine sweat glands or a peculiar functional activity of eccrine sweat glands. © 2013 Wiley Periodicals, Inc.

  9. How MAG4 Improves Space Weather Forecasting

    NASA Technical Reports Server (NTRS)

    Falconer, David; Khazanov, Igor; Barghouty, Nasser

    2013-01-01

    Dangerous space weather is driven by solar flares and Coronal Mass Ejection (CMEs). Forecasting flares and CMEs is the first step to forecasting either dangerous space weather or All Clear. MAG4 (Magnetogram Forecast), developed originally for NASA/SRAG (Space Radiation Analysis Group), is an automated program that analyzes magnetograms from the HMI (Helioseismic and Magnetic Imager) instrument on NASA SDO (Solar Dynamics Observatory), and automatically converts the rate (or probability) of major flares (M- and X-class), Coronal Mass Ejections (CMEs), and Solar Energetic Particle Events.

  10. Uploading, Searching and Visualizing of Paleomagnetic and Rock Magnetic Data in the Online MagIC Database

    NASA Astrophysics Data System (ADS)

    Minnett, R.; Koppers, A.; Tauxe, L.; Constable, C.; Donadini, F.

    2007-12-01

    The Magnetics Information Consortium (MagIC) is commissioned to implement and maintain an online portal to a relational database populated by both rock and paleomagnetic data. The goal of MagIC is to archive all available measurements and derived properties from paleomagnetic studies of directions and intensities, and for rock magnetic experiments (hysteresis, remanence, susceptibility, anisotropy). MagIC is hosted under EarthRef.org at http://earthref.org/MAGIC/ and will soon implement two search nodes, one for paleomagnetism and one for rock magnetism. Currently the PMAG node is operational. Both nodes provide query building based on location, reference, methods applied, material type and geological age, as well as a visual map interface to browse and select locations. Users can also browse the database by data type or by data compilation to view all contributions associated with well known earlier collections like PINT, GMPDB or PSVRL. The query result set is displayed in a digestible tabular format allowing the user to descend from locations to sites, samples, specimens and measurements. At each stage, the result set can be saved and, where appropriate, can be visualized by plotting global location maps, equal area, XY, age, and depth plots, or typical Zijderveld, hysteresis, magnetization and remanence diagrams. User contributions to the MagIC database are critical to achieving a useful research tool. We have developed a standard data and metadata template (version 2.3) that can be used to format and upload all data at the time of publication in Earth Science journals. Software tools are provided to facilitate population of these templates within Microsoft Excel. These tools allow for the import/export of text files and provide advanced functionality to manage and edit the data, and to perform various internal checks to maintain data integrity and prepare for uploading. The MagIC Contribution Wizard at http://earthref.org/MAGIC/upload.htm executes the upload

  11. An Accessory Muscle of Pectoral Region: A Case Report

    PubMed Central

    Bannur, B.M.; Mallashetty, Nagaraj; Endigeri, Preetish

    2013-01-01

    Among the variations of pectoral muscles, this case appears to be unique in the literature. This was a case of an accessory pectoral muscle which was located between pectoralis major and pectoralis minor muscles, which was discovered during a routine anatomy dissection. The accessory muscle originated from 6th and 7th ribs at costo-chondral junction, which travelled supero-laterally and inserted by fusing with fibres of pectoralis minor. This unusual muscle holds importance for surgeons while they perform dissectomies, in avoiding complications. PMID:24179919

  12. Hairy cell leukaemia complicated by anti-MAG paraproteinemic demyelinating neuropathy: resolution of neurological syndrome after cladribrine treatment.

    PubMed

    Rossi, Davide; Franceschetti, Silvia; Cerri, Michaela; Conconi, Annarita; Lunghi, Monia; Capello, Daniela; Cantello, Roberto; Gaidano, Gianluca

    2007-06-01

    Hairy cell leukaemia (HCL) occasionally displays a monoclonal gammopathy, yet the association of HCL with paraproteinemic demyelinating neuropathy (PDN) has not been reported. We describe a HCL case complicated by PDN and high titers of monoclonal IgM against myelin associated glycoprotein (MAG). Heavy and light chains of the patient's anti-MAG monoclonal protein were consistent with those expressed by HCL cells. After treatment with cladribrine, remission of HCL strictly paralleled disappearance of the IgM monoclonal protein and of the serum anti-MAG activity, and led to PDN clinical and electrophysiological improvement. Purine analogs may represent a choice in IgM PDN associated with lymphoproliferative disorders.

  13. Headgear Accessories Classification Using an Overhead Depth Sensor

    PubMed Central

    Luna, Carlos A.; Marron-Romera, Marta; Mazo, Manuel; Luengo-Sanchez, Sara; Macho-Pedroso, Roberto

    2017-01-01

    In this paper, we address the generation of semantic labels describing the headgear accessories carried out by people in a scene under surveillance, only using depth information obtained from a Time-of-Flight (ToF) camera placed in an overhead position. We propose a new method for headgear accessories classification based on the design of a robust processing strategy that includes the estimation of a meaningful feature vector that provides the relevant information about the people’s head and shoulder areas. This paper includes a detailed description of the proposed algorithmic approach, and the results obtained in tests with persons with and without headgear accessories, and with different types of hats and caps. In order to evaluate the proposal, a wide experimental validation has been carried out on a fully labeled database (that has been made available to the scientific community), including a broad variety of people and headgear accessories. For the validation, three different levels of detail have been defined, considering a different number of classes: the first level only includes two classes (hat/cap, and no hat/cap), the second one considers three classes (hat, cap and no hat/cap), and the last one includes the full class set with the five classes (no hat/cap, cap, small size hat, medium size hat, and large size hat). The achieved performance is satisfactory in every case: the average classification rates for the first level reaches 95.25%, for the second one is 92.34%, and for the full class set equals 84.60%. In addition, the online stage processing time is 5.75 ms per frame in a standard PC, thus allowing for real-time operation. PMID:28796177

  14. 21 CFR 884.1720 - Gynecologic laparoscope and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... accessory instruments include: the lens cleaning brush, biopsy brush, clip applier (without clips...), retractor, mechanical (noninflatable), snare, stylet, forceps, dissector, mechanical (noninflatable...

  15. 21 CFR 884.1720 - Gynecologic laparoscope and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... accessory instruments include: the lens cleaning brush, biopsy brush, clip applier (without clips...), retractor, mechanical (noninflatable), snare, stylet, forceps, dissector, mechanical (noninflatable...

  16. 21 CFR 884.1720 - Gynecologic laparoscope and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... accessory instruments include: the lens cleaning brush, biopsy brush, clip applier (without clips...), retractor, mechanical (noninflatable), snare, stylet, forceps, dissector, mechanical (noninflatable...

  17. Association of estradiol on expression of melanocortin receptors and their accessory proteins in the liver of chicken (Gallus gallus).

    PubMed

    Ren, Junxiao; Li, Yanmin; Xu, Naiyi; Li, Hong; Li, Cuicui; Han, Ruili; Wang, Yanbin; Li, Zhuanjian; Kang, Xiangtao; Liu, Xiaojun; Tian, Yadong

    2017-01-01

    The melanocortin receptor accessory proteins (MRAP and MRAP2) are small single-pass transmembrane proteins that regulate the biological functions of the melanocortin receptor (MCR) family. MCRs comprise five receptors (MC1R-MC5R) with diverse physiological roles in mammals. Five MCR members and two MRAPs were also predicted in the chicken (Gallus gallus) genome. However, little is known about their expression, regulation and biological functions. In this study, we cloned the MRAP and MRAP2 genes. Sequencing analysis revealed that the functional domains of MRAP and MRAP2 were conserved among species, suggesting that the physiological roles of chicken MRAP and MRAP2 could be similar to their mammalian counterparts. Tissue expression analysis demonstrated that MRAP was expressed in the adrenal gland, liver, spleen, glandular stomach and lungs, while MRAP2 is predominantly expressed in the adrenal gland. All five MCRs were present in the adrenal gland, but showed different expression patterns in other tissues. The MC5R was the only MCR member that was expressed in the chicken liver. The expression levels of MRAP in chicken liver were significantly increased at sexual maturity stage, and were significantly up-regulated (P<0.05) when chickens and chicken primary hepatocytes were treated with 17β-estradiol in vivo and in vitro, respectively; however, expression levels of PPARγ were down-regulated, and no effect on MC5R was observed. Our results suggested that estrogen could stimulate the expression of MRAP in the liver of chicken through inhibiting the expression of transcription regulation factor PPARγ, and MRAP might play its biological role in a different way rather than forming an MRAP/MC2R complex in chicken liver during the egg-laying period. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. The role of accessory cells in polyclonal T cell activation. I. Both induction of interleukin 2 production and of interleukin 2 responsiveness by concanavalin A are accessory cell dependent.

    PubMed

    Hünig, T; Loos, M; Schimpl, A

    1983-01-01

    Recent studies from other laboratories have shown that concanavalin A (Con A) acts at two separate steps in polyclonal T cell activation: interleukin 2 (IL2) production, and induction of responsiveness to IL2. Using a combination of techniques for the depletion of accessory cells from lymph node T cells, we have investigated which of these steps, if not both, is responsible for the known requirement for accessory cells in the Con A response. It was found that with increasing T cell purification, first the ability is lost to produce sufficient levels of endogenous IL2, whereas induction of IL2 responsiveness can still take place. Further removal of accessory cells however yields a population of resting T cells that cannot be induced by Con A to become IL2-reactive. It was concluded that both IL2 production and induction of reactivity to IL2 are accessory cell-dependent events.

  19. Modeling and Simulation of Two Wheelchair Accessories for Pushing Doors.

    PubMed

    Abdullah, Soran Jalal; Shaikh Mohammed, Javeed

    2017-03-27

    Independent mobility is vital to individuals of all ages, and wheelchairs have proven to be great personal mobility devices. The tasks of opening and navigating through a door are trivial for healthy people, while the same tasks could be difficult for some wheelchair users. A wide range of intelligent wheelchair controllers and systems, robotic arms, or manipulator attachments integrated with wheelchairs have been developed for various applications, including manipulating door knobs. Unfortunately, the intelligent wheelchairs and robotic attachments are not widely available as commercial products. Therefore, the current manuscript presents the modeling and simulation of a novel but simple technology in the form of a passive wheelchair accessory (straight, arm-like with a single wheel, and arc-shaped with multiple wheels) for pushing doors open from a wheelchair. From the simulations using different wheel shapes and sizes, it was found that the arc-shaped accessory could push open the doors faster and with almost half the required force as compared to the arm-like accessory. Also, smaller spherical wheels were found to be best in terms of reaction forces on the wheels. Prototypes based on the arc-shaped accessory design will be manufactured and evaluated for pushing doors open and dodging or gliding other obstacles.

  20. Adrenal Gland Tumors: Statistics

    MedlinePlus

    ... Gland Tumor: Statistics Request Permissions Adrenal Gland Tumor: Statistics Approved by the Cancer.Net Editorial Board , 03/ ... primary adrenal gland tumor is very uncommon. Exact statistics are not available for this type of tumor ...

  1. Can computed tomography volumetry of the renal cortex replace MAG3-scintigraphy in all patients for determining split renal function?

    PubMed

    Houbois, Christian; Haneder, Stefan; Merkt, Martin; Morelli, John N; Schmidt, Matthias; Hellmich, Martin; Mueller, Roman-Ulrich; Wahba, Roger; Maintz, David; Puesken, Michael

    2018-06-01

    The current gold standard for determination of split renal function (SRF) is Tc-99m-mercapto-acetyltriglycin (MAG3) scintigraphy. Initial studies comparing MAG3-scintigraphy and CT-based renal cortex volumetry (RCV) for calculation of SRF have shown similar results in highly selected patient collectives with normal renal function (i.e. living kidney donors). This study aims to compare MAG3-scintigraphy and CT-RCV within a large unselected patient collective including patients with impaired renal function. For this assessment, 279 datasets (131 men, 148 women; mean age: 54.2 ± 12.9 years, range: 24-84 years) of patients who underwent MAG3-scintigraphy and contrast-enhanced abdominal CT within two weeks were retrospectively analyzed. Two independent readers assessed the CT-RCV in all CT datasets using a semi-automated volumetry tool. The MAG3-scintigraphy and CT-RCV methods were compared, stratified for the eGFR. Statistical analysis included descriptive statistics as well as inter- observer agreement. The absolute mean difference between the percentage contribution of the left and the right kidneys in total MAG3-clearance was 8.6%. Independent of eGFR, an overall sufficient agreement between both methods was established in all patients. A relatively small, tolerable systemic error resulted in an underestimation (max. 2%) of the left renal contribution to overall RCV. The results demonstrate that CT-RCV is a potential clinical replacement for MAG3-scintigraphy for calculation of SRF: CT-RCV demonstrates clinically tolerable differences with MAG3-scintigraphy, independent of patient eGFR. The relative complexity of the RCV method utilized is a potential limitation and may have contributed to the acceptable but only fair to moderate level of intra-reader reliability. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Adolescent accessory navicular.

    PubMed

    Leonard, Zachary C; Fortin, Paul T

    2010-06-01

    Accessory tarsal navicular is a common anomaly in the human foot. It should be in the differential of medial foot pain. A proper history and physical, along with imaging modalities, can lead to the diagnosis. Often, classification of the ossicle and amount of morbidity guide treatment. Nonsurgical measures can provide relief. A variety of surgical procedures have been used with good results. Our preferred method is excision for small ossicles and segmental fusion after removal of the synchondrosis for large ossicles. In addition, pes planovalgus deformities need to be addressed concomitantly. Copyright 2010 Elsevier Inc. All rights reserved.

  3. Variations in the surface anatomy of the spinal accessory nerve in the posterior triangle.

    PubMed

    Symes, A; Ellis, H

    2005-12-01

    Iatrogenic injury to the spinal accessory nerve has been widely documented and can have medico-legal implications. The resulting syndrome of pain, paralysis and winging of the scapula are often the source of considerable morbidity. This paper researches the degree of accuracy achievable in mapping the surface anatomy of the spinal accessory nerve in the region of the posterior triangle with a view to creating a cartographical aid to surgical procedures. The necks of 25 adult cadavers were dissected bilaterally to expose the spinal accessory nerve. Variations in the course and distribution of the spinal accessory nerve in the posterior triangle were recorded along with its relationship to the borders of sternocleidomastoid and trapezius. Considerable variation was seen in the surface and regional anatomy of the nerve and in the contribution of the cervical plexus to the spinal accessory nerve in the posterior triangle. Measurements of the running course and exit point of the nerve into and from the posterior triangle differed significantly from those previously recorded. Delineation of an accurate surface anatomy was not possible. Creating a map to define the surface anatomy of the spinal accessory nerve in the posterior triangle is an unrealistic goal given its wide variations in man. Avoidance of damage to the spinal accessory nerve cannot be achieved by slavishly adhering to surface markings given in textbooks, but only by cautious dissection during operations on the posterior triangle.

  4. 21 CFR 890.3910 - Wheelchair accessory.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wheelchair accessory. 890.3910 Section 890.3910 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3910 Wheelchair...

  5. 21 CFR 890.3910 - Wheelchair accessory.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wheelchair accessory. 890.3910 Section 890.3910 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3910 Wheelchair...

  6. 21 CFR 890.3910 - Wheelchair accessory.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wheelchair accessory. 890.3910 Section 890.3910 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3910 Wheelchair...

  7. 21 CFR 890.3910 - Wheelchair accessory.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wheelchair accessory. 890.3910 Section 890.3910 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3910 Wheelchair...

  8. 21 CFR 890.3910 - Wheelchair accessory.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wheelchair accessory. 890.3910 Section 890.3910 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3910 Wheelchair...

  9. Morganella morganii bacteria produces phenol as the sex pheromone of the New Zealand grass grub from tyrosine in the colleterial gland

    NASA Astrophysics Data System (ADS)

    Marshall, D. G.; Jackson, T. A.; Unelius, C. R.; Wee, S. L.; Young, S. D.; Townsend, R. J.; Suckling, D. M.

    2016-08-01

    Costelytra zealandica (Coleoptera: Scarabeidae) is a univoltine endemic species that has colonised and become a major pest of introduced clover and ryegrass pastures that form about half of the land area of New Zealand. Female beetles were previously shown to use phenol as their sex pheromone produced by symbiotic bacteria in the accessory or colleterial gland. In this study, production of phenol was confirmed from the female beetles, while bacteria were isolated from the gland and tested for attractiveness towards grass grub males in traps in the field. The phenol-producing bacterial taxon was identified by partial sequencing of the 16SrRNA gene, as Morganella morganii. We then tested the hypothesis that the phenol sex pheromone is biosynthesized from the amino acid tyrosine by the bacteria. This was shown to be correct, by addition of isotopically labelled tyrosine (13C) to the bacterial broth, followed by detection of the labelled phenol by SPME-GCMS. Elucidation of this pathway provides specific evidence how the phenol is produced as an insect sex pheromone by a mutualistic bacteria.

  10. Managing Rock and Paleomagnetic Data Flow with the MagIC Database: from Measurement and Analysis to Comprehensive Archive and Visualization

    NASA Astrophysics Data System (ADS)

    Koppers, A. A.; Minnett, R. C.; Tauxe, L.; Constable, C.; Donadini, F.

    2008-12-01

    The Magnetics Information Consortium (MagIC) is commissioned to implement and maintain an online portal to a relational database populated by rock and paleomagnetic data. The goal of MagIC is to archive all measurements and derived properties for studies of paleomagnetic directions (inclination, declination) and intensities, and for rock magnetic experiments (hysteresis, remanence, susceptibility, anisotropy). Organizing data for presentation in peer-reviewed publications or for ingestion into databases is a time-consuming task, and to facilitate these activities, three tightly integrated tools have been developed: MagIC-PY, the MagIC Console Software, and the MagIC Online Database. A suite of Python scripts is available to help users port their data into the MagIC data format. They allow the user to add important metadata, perform basic interpretations, and average results at the specimen, sample and site levels. These scripts have been validated for use as Open Source software under the UNIX, Linux, PC and Macintosh© operating systems. We have also developed the MagIC Console Software program to assist in collating rock and paleomagnetic data for upload to the MagIC database. The program runs in Microsoft Excel© on both Macintosh© computers and PCs. It performs routine consistency checks on data entries, and assists users in preparing data for uploading into the online MagIC database. The MagIC website is hosted under EarthRef.org at http://earthref.org/MAGIC/ and has two search nodes, one for paleomagnetism and one for rock magnetism. Both nodes provide query building based on location, reference, methods applied, material type and geological age, as well as a visual FlashMap interface to browse and select locations. Users can also browse the database by data type (inclination, intensity, VGP, hysteresis, susceptibility) or by data compilation to view all contributions associated with previous databases, such as PINT, GMPDB or TAFI or other user

  11. 29 CFR 1919.28 - Unit proof tests-cranes and gear accessory thereto.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Unit proof tests-cranes and gear accessory thereto. 1919.28... ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) GEAR CERTIFICATION Certification of Vessels: Tests and Proof Loads; Heat Treatment; Competent Persons § 1919.28 Unit proof tests—cranes and gear accessory thereto...

  12. Comparative anatomy of the accessory ciliary ganglion in mammals.

    PubMed

    Kuchiiwa, S; Kuchiiwa, T; Suzuki, T

    1989-01-01

    The orbits of 13 mammalian species (pig, sika deer, domestic sheep, horse, cat, fox, racoon dog, marten, rat, rabbit, crab-eating macaque, japanese macaque and man) were stained with silver nitrate and dissected under a dissecting microscope with special attention to the presence and location of the accessory ciliary ganglion. Some preparations were stained with thionin and examined as whole-mounts in a transmission microscope. The accessory ciliary ganglion was present in all 13 species, although the number and degree of development varied greatly from species to species. The accessory ciliary ganglion could be readily differentiated from the main ciliary ganglion in the following respects: it was located on the short ciliary nerve, and it had no root derived directly from the inferior trunk of the oculomotor nerve and it never attaches to this nerve. In many species, ganglion cells were also scattered in the short ciliary nerves in the stained whole preparations. In a few species, there were one or more small ganglia on the nerve to the inferior oblique muscle.

  13. Mammary Gland Development

    PubMed Central

    Macias, Hector

    2012-01-01

    The mammary gland develops through several distinct stages. The first transpires in the embryo as the ectoderm forms a mammary line that resolves into placodes. Regulated by epithelial/mesenchymal interactions, the placodes descend into the underlying mesenchyme and produce the rudimentary ductal structure of the gland present at birth. Subsequent stages of development – pubertal growth, pregnancy, lactation and involution – occur postnatally under the regulation of hormones. Puberty initiates branching morphogenesis, which requires growth hormone and estrogen, as well as IGF1, to create a ductal tree that fills the fat pad. Upon pregnancy the combined actions of progesterone and prolactin generate alveoli, which secrete milk during lactation. Lack of demand for milk at weaning initiates the process of involution whereby the gland is remodeled back to its pre-pregnancy state. These processes require numerous signaling pathways that have distinct regulatory functions at different stages of gland development. Signaling pathways also regulate a specialized subpopulation of mammary stem cells that fuel the dramatic changes in the gland occurring with each pregnancy. Our knowledge of mammary gland development and mammary stem cell biology has significantly contributed to our understanding of breast cancer and has advanced the discovery of therapies to treat this disease. PMID:22844349

  14. The clypeal gland: a new exocrine gland in termite imagoes (Isoptera: Serritermitidae, Rhinotermitidae, Termitidae).

    PubMed

    Křížková, Barbora; Bourguignon, Thomas; Vytisková, Blahoslava; Sobotník, Jan

    2014-11-01

    Social insects possess a rich set of exocrine organs producing diverse pheromones and defensive compounds. This is especially true for termite imagoes, which are equipped with several glands producing, among others, sex pheromones and defensive compounds protecting imagoes during the dispersal flight and colony foundation. Here, we describe the clypeal gland, a new termite exocrine organ occurring in the labro-clypeal region of imagoes of most Rhinotermitidae, Serritermitidae and Termitidae species. The clypeal gland of Coptotermes testaceus consists of class 1 (modified epidermal cell) and class 3 (bicellular gland unit) secretory cells. Ultrastructural features suggest that the gland secretes volatile compounds and proteins, probably after starting the reproduction. One peculiar feature of the gland is the presence of multiple secretory canals in a single canal cell, a feature never observed before in other insect glands. Although the function of the gland remains unknown, we hypothesize that it could produce secretion signalling the presence of functional reproductives or their need to be fed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Diverse Broad-Host-Range Plasmids from Freshwater Carry Few Accessory Genes

    PubMed Central

    Sen, Diya; Yano, Hirokazu; Bauer, Matthew L.; Rogers, Linda M.; Van der Auwera, Geraldine A.

    2013-01-01

    Broad-host-range self-transferable plasmids are known to facilitate bacterial adaptation by spreading genes between phylogenetically distinct hosts. These plasmids typically have a conserved backbone region and a variable accessory region that encodes host-beneficial traits. We do not know, however, how well plasmids that do not encode accessory functions can survive in nature. The goal of this study was to characterize the backbone and accessory gene content of plasmids that were captured from freshwater sources without selecting for a particular phenotype or cultivating their host. To do this, triparental matings were used such that the only required phenotype was the plasmid's ability to mobilize a nonconjugative plasmid. Based on complete genome sequences of 10 plasmids, only 5 carried identifiable accessory gene regions, and none carried antibiotic resistance genes. The plasmids belong to four known incompatibility groups (IncN, IncP-1, IncU, and IncW) and two potentially new groups. Eight of the plasmids were shown to have a broad host range, being able to transfer into alpha-, beta-, and gammaproteobacteria. Because of the absence of antibiotic resistance genes, we resampled one of the sites and compared the proportion of captured plasmids that conferred antibiotic resistance to their hosts with the proportion of such plasmids captured from the effluent of a local wastewater treatment plant. Few of the captured plasmids from either site encoded antibiotic resistance. A high diversity of plasmids that encode no or unknown accessory functions is thus readily found in freshwater habitats. The question remains how the plasmids persist in these microbial communities. PMID:24096417

  16. 47 CFR 15.27 - Special accessories.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Special accessories. 15.27 Section 15.27 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.27 Special... manual is provided only in a form other than paper, such as on a computer disk or over the Internet, the...

  17. 47 CFR 15.27 - Special accessories.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Special accessories. 15.27 Section 15.27 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.27 Special... manual is provided only in a form other than paper, such as on a computer disk or over the Internet, the...

  18. 47 CFR 15.27 - Special accessories.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Special accessories. 15.27 Section 15.27 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.27 Special... manual is provided only in a form other than paper, such as on a computer disk or over the Internet, the...

  19. 47 CFR 15.27 - Special accessories.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Special accessories. 15.27 Section 15.27 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.27 Special... manual is provided only in a form other than paper, such as on a computer disk or over the Internet, the...

  20. 29 CFR 1919.28 - Unit proof tests-cranes and gear accessory thereto.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 7 2011-07-01 2011-07-01 false Unit proof tests-cranes and gear accessory thereto. 1919.28... Loads; Heat Treatment; Competent Persons § 1919.28 Unit proof tests—cranes and gear accessory thereto. (a) Except as noted in paragraph (e) of this section, cranes and other hoisting machines, together...

  1. Benign Pediatric Salivary Gland Lesions.

    PubMed

    Carlson, Eric R; Ord, Robert A

    2016-02-01

    Salivary gland lesions are rare in pediatric patients. In addition, the types of salivary gland tumors are different in their distribution in specific sites in the major and minor salivary glands in children compared with adults. This article reviews benign neoplastic and nonneoplastic salivary gland disorders in pediatric patients to help clinicians to develop an orderly differential diagnosis that will lead to expedient treatment of pediatric patients with salivary gland lesions. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. [Investigations on the pathogenesis of changes in somatic growth of Lymnaea stagnalis (Gastropoda: Pulmonata) experimentally infected with parthenites Opisthioglyphe ranae (Digenea: Plagiorchiida). I. Relative weight of accessory sex organs and synthetic activity of neurosecretory cells].

    PubMed

    Pokora, Z

    1996-01-01

    In the paper an attempt to define pathogenesis of changes in somatic growth of juvenile individuals of the popular freshwater snail Lymnaea stagnalis experimentally infected with parthenites of the trematode Opisthioglyphe ranae was undertaken. Significant enlargement of relative wet weight of examined accessory sex organs (albumen gland, oothecal gland, prostate, male copulatory organ) observed in infected snails permits to explain increase of their somatic growth basing on the hypothesis of disturbances in energetistic budget of the host-as a consequence of reduction by the parasite activity of the snail's reproductive system. Pathogenesis of this phenomenon has probably a complicated character, including also effect of parthenites on activity of the neurosecretory cells that control somatic growth in examined species of the snail. An argument for this standpoint is, observed in infected snails, increase of amount of neurosecretory material and RNA in cytoplasm of these cells (the light green cells of cerebral ganglia), as well as amount of the loose fraction of chromatine in their nuclei.

  3. Accessory Axillary Breast Excision with Liposuction Using Minimal Incision: A Preliminary Report.

    PubMed

    Hwang, Seong Bae; Choi, Byung Seo; Byun, Geon Young; Koo, Bum Hwan; Lee, Sung Ryul

    2017-02-01

    Accessory breasts have received little attention in the surgical fields, although the condition is quite common in the female population, with 2-6% of women suffering from it. Its convexity and cyclic pain make women feel embarrassed and uncomfortable, so patients often desire surgical excision to improve their appearances and to remove the pain. A total of 967 patients who had been treated by an excision of accessory breast tissue with liposuction using minimal incision from September 2013 to Dec 2015 at the Damsoyu Hospital were analyzed for clinical factors retrospectively. All 967 patients were female. There were 514 (53.2%) unmarried patients and 453 (46.8%) married patients. The major clinical manifestation was the problem in the appearance with cyclic pain in both unmarried and married groups (82.7 vs. 87.9%). Three types of accessory breasts were observed: 779 (80.6%) breast tissue only in axillae, 182 (18.8%) breast tissue with accessory nipple, and 6 (0.6%) breast tissue with accessory nipple-areolar complex. The mean operation time was 58 min. All cyclic axillar pain in our cases was resolved after the operation. Postoperative complications developed in 160 patients (16.55%). Among them, seroma after operation was the most common (11.27%). In our study, 95.65% of the patients were satisfied with the cosmetic outcomes. The surgical excision of accessory breasts with liposuction through the minimal incision is a safe and effective method to make women feel comfortable in clinical manifestations and be satisfied with their cosmetic axillar line. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  4. Into the blue: AO science with MagAO in the visible

    NASA Astrophysics Data System (ADS)

    Close, Laird M.; Males, Jared R.; Follette, Katherine B.; Hinz, Phil; Morzinski, Katie; Wu, Ya-Lin; Kopon, Derek; Riccardi, Armando; Esposito, Simone; Puglisi, Alfio; Pinna, Enrico; Xompero, Marco; Briguglio, Runa; Quiros-Pacheco, Fernando

    2014-08-01

    We review astronomical results in the visible (λ<1μm) with adaptive optics. Other than a brief period in the early 1990s, there has been little astronomical science done in the visible with AO until recently. The most productive visible AO system to date is our 6.5m Magellan telescope AO system (MagAO). MagAO is an advanced Adaptive Secondary system at the Magellan 6.5m in Chile. This secondary has 585 actuators with < 1 msec response times (0.7 ms typically). We use a pyramid wavefront sensor. The relatively small actuator pitch (~23 cm/subap) allows moderate Strehls to be obtained in the visible (0.63-1.05 microns). We use a CCD AO science camera called "VisAO". On-sky long exposures (60s) achieve <30mas resolutions, 30% Strehls at 0.62 microns (r') with the VisAO camera in 0.5" seeing with bright R < 8 mag stars. These relatively high visible wavelength Strehls are made possible by our powerful combination of a next generation ASM and a Pyramid WFS with 378 controlled modes and 1000 Hz loop frequency. We'll review the key steps to having good performance in the visible and review the exciting new AO visible science opportunities and refereed publications in both broad-band (r,i,z,Y) and at Halpha for exoplanets, protoplanetary disks, young stars, and emission line jets. These examples highlight the power of visible AO to probe circumstellar regions/spatial resolutions that would otherwise require much larger diameter telescopes with classical infrared AO cameras.

  5. The Primary Duct of Bothrops jararaca Glandular Apparatus Secretes Toxins

    PubMed Central

    Sakai, Fernanda; Portes-Junior, José Antonio; Godoy Viana, Luciana; Mendes Carneiro, Sylvia; Perales, Jonas; Yamanouye, Norma

    2018-01-01

    Despite numerous studies concerning morphology and venom production and secretion in the main venom gland (and some data on the accessory gland) of the venom glandular apparatus of Viperidae snakes, the primary duct has been overlooked. We characterized the primary duct of the Bothrops jararaca snake by morphological analysis, immunohistochemistry and proteomics. The duct has a pseudostratified epithelium with secretory columnar cells with vesicles of various electrondensities, as well as mitochondria-rich, dark, basal, and horizontal cells. Morphological analysis, at different periods after venom extraction, showed that the primary duct has a long cycle of synthesis and secretion, as do the main venom and accessory glands; however, the duct has a mixed mode venom storage, both in the lumen and in secretory vesicles. Mouse anti-B. jararaca venom serum strongly stained the primary duct’s epithelium. Subsequent proteomic analysis revealed the synthesis of venom toxins—mainly C-type lectin/C-type lectin-like proteins. We propose that the primary duct’s toxin synthesis products complement the final venom bolus. Finally, we hypothesize that the primary duct and the accessory gland (components of the venom glandular apparatus) are part of the evolutionary path from a salivary gland towards the main venom gland. PMID:29533989

  6. Electrophysiological mapping of the accessory olfactory bulb of the rabbit (Oryctolagus cuniculus).

    PubMed

    van Groen, T; Ruardy, L; da Silva, F H

    1986-07-01

    Field potentials elicited by electrical stimulation of the vomeronasal nerve were measured in the accessory olfactory bulb of the rabbit. Maps were made of the distribution of surface field potentials and of the corresponding depth profiles. The surface maps followed closely the contours of the accessory olfactory bulb: at the frontal border the field potential tended to zero and at the center of the structure the field potential attained a maximum. Depth profiles of the field potentials through the accessory olfactory bulb presented a surface-negative wave and, in depth, a positive wave. The polarity reversal occurred at the deep part of the granule cell layer. The zero equipotential line followed closely the curvature of the granule cell layer. Current source density analysis of the depth profiles revealed a main sink at the external plexiform and granule cell layers. This indicates that the main activity in the accessory olfactory bulb is generated by the synapses between the mitral cells and the granule cells as is found in the main olfactory bulb.

  7. Spinal Accessory Motor Neurons in the Mouse: A Special Type of Branchial Motor Neuron?

    PubMed

    Watson, Charles; Tvrdik, Petr

    2018-04-16

    The spinal accessory nerve arises from motor neurons in the upper cervical spinal cord. The axons of these motor neurons exit dorsal to the ligamentum denticulatum and form the spinal accessory nerve. The nerve ascends in the spinal subarachnoid space to enter the posterior cranial fossa through the foramen magnum. The spinal accessory nerve then turns caudally to exit through the jugular foramen alongside the vagus and glossopharyngeal nerves, and then travels to supply the sternomastoid and trapezius muscles in the neck. The unusual course of the spinal accessory nerve has long prompted speculation that it is not a typical spinal motor nerve and that it might represent a caudal remnant of the branchial motor system. Our cell lineage tracing data, combined with images from public databases, show that the spinal accessory motor neurons in the mouse transiently express Phox2b, a transcription factor that is required for development of brain stem branchial motor nuclei. While this is strong prima facie evidence that the spinal accessory motor neurons should be classified as branchial motor, the evolutionary history of these motor neurons in anamniote vertebrates suggests that they may be considered to be an atypical branchial group that possesses both branchial and somatic characteristics. Anat Rec, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  8. 21 CFR 884.4100 - Endoscopic electrocautery and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... coagulate fallopian tube tissue with a probe heated by low-voltage energy. This generic type of device may include the following accessories: electrical generators, probes, and electrical cables. (b...

  9. 21 CFR 884.4100 - Endoscopic electrocautery and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... coagulate fallopian tube tissue with a probe heated by low-voltage energy. This generic type of device may include the following accessories: electrical generators, probes, and electrical cables. (b...

  10. 21 CFR 884.4100 - Endoscopic electrocautery and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... coagulate fallopian tube tissue with a probe heated by low-voltage energy. This generic type of device may include the following accessories: electrical generators, probes, and electrical cables. (b...

  11. 21 CFR 884.4100 - Endoscopic electrocautery and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... coagulate fallopian tube tissue with a probe heated by low-voltage energy. This generic type of device may include the following accessories: electrical generators, probes, and electrical cables. (b...

  12. 21 CFR 884.1720 - Gynecologic laparoscope and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... genital organs. This generic type of device may include: Trocar and cannula, instruments used through an... accessory instruments include: the lens cleaning brush, biopsy brush, clip applier (without clips...

  13. 21 CFR 884.1720 - Gynecologic laparoscope and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... genital organs. This generic type of device may include: Trocar and cannula, instruments used through an... accessory instruments include: the lens cleaning brush, biopsy brush, clip applier (without clips...

  14. Reconstructive surgery using interference screw fixation for painful accessory navicular in adult athletes.

    PubMed

    Miyamoto, Wataru; Takao, Masato; Yamada, Kazuaki; Yasui, Youichi; Matsushita, Takashi

    2012-10-01

    To examine the effectiveness of a new technique for reattaching the posterior tibial tendon (PTT) using a bone tunnel and interference screw after resection of the accessory navicular for painful accessory navicular (type II) in adult athletes. Ten adult athletes (7 male, 3 female; mean age 30 years, range 23-45) underwent reconstruction using a bone tunnel with an interference screw for a painful accessory navicular. All patients complained of pain on the medial aspect of the foot after eversion sprain during sports activities and radiographs revealed type II accessory navicular. Clinical evaluation with the American Orthopaedic Foot and Ankle Society Ankle-Hindfoot Scale (AOFAS) and visual analogue scale (VAS) before surgery was compared with that at most recent follow up (mean 30 months, range 24-39). Mean AOFAS score improved from a preoperative 62.8 ± 2.9 points (range 61-82) to a postoperative 92.1 ± 7.0 points (range 83-100; p < 0.01). Furthermore, mean VAS score improved from a preoperative 92.5 ± 5.4 points (range 85-100) to a postoperative 4.5 ± 3.8 points (range 0-10; p < 0.01). All patients could return to full sports activity at a mean of 14 weeks (range 12-18) after surgery. The presented technique reconstructs the bone-tendon interface of the PTT at the primary navicular with sufficient fixation after resection of the accessory navicular, which preserves the strength of the PTT in adult athletes with an intractably painful accessory navicular.

  15. Development and Application of an Indirect Enzyme-Linked Immunosorbent Assay Using Recombinant Mag1 for Serodiagnosis of Toxoplasma gondii In Dogs.

    PubMed

    Zhuo, Xunhui; Sun, Hongchao; Zhang, Zhi; Luo, Jiaqing; Shan, Ying; Du, Aifang

    2017-06-01

    Serologic tests are widely accepted and applied as means to detect anti- Toxoplasma gondii immunoglobulin G antibodies. In this study, recombinant matrix antigen (rMAG1) was induced by isopropyl-β-d-thiogalactoside and purified by nickel-nitrilotriacetic acid purification system. We then developed and optimized an indirect enzyme-linked immunosorbent assay (ELISA) through checkerboard assays using serial dilutions of antigens and sera to assess the potential use of rMAG1 in serologic detection of T. gondii infection in dogs. Serum samples from 93 domestic dogs were analyzed by western blot and rMAG1-ELISA. The results were compared with those obtained from an ELISA with the soluble Toxoplasma lysate antigens (TLA). We found that although yielding an excellent agreement (96.7%) with western blot data (κ = 0.9659), rMAG1-ELISA produced higher sensitivity (93.9% vs. 87.8%) and specificity (98.3% vs. 96.7%) than TLA-ELISA. In addition, receiver operating characteristic analysis also revealed that rMAG1-ELISA is in more agreement with western blot (area under the curve [AUC] = 0.985) relative to TLA-ELISA (AUC = 0.955). These results indicated that the rMAG1-ELISA established in this study provides a promising and reliable tool for serologic detection of T. gondii infection in dogs.

  16. 21 CFR 888.3030 - Single/multiple component metallic bone fixation appliances and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Single/multiple component metallic bone fixation....3030 Single/multiple component metallic bone fixation appliances and accessories. (a) Identification. Single/multiple component metallic bone fixation appliances and accessories are devices intended to be...

  17. 21 CFR 888.3030 - Single/multiple component metallic bone fixation appliances and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Single/multiple component metallic bone fixation....3030 Single/multiple component metallic bone fixation appliances and accessories. (a) Identification. Single/multiple component metallic bone fixation appliances and accessories are devices intended to be...

  18. 21 CFR 888.3030 - Single/multiple component metallic bone fixation appliances and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Single/multiple component metallic bone fixation....3030 Single/multiple component metallic bone fixation appliances and accessories. (a) Identification. Single/multiple component metallic bone fixation appliances and accessories are devices intended to be...

  19. 21 CFR 888.3030 - Single/multiple component metallic bone fixation appliances and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Single/multiple component metallic bone fixation....3030 Single/multiple component metallic bone fixation appliances and accessories. (a) Identification. Single/multiple component metallic bone fixation appliances and accessories are devices intended to be...

  20. 21 CFR 888.3030 - Single/multiple component metallic bone fixation appliances and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Single/multiple component metallic bone fixation....3030 Single/multiple component metallic bone fixation appliances and accessories. (a) Identification. Single/multiple component metallic bone fixation appliances and accessories are devices intended to be...

  1. Adrenal Gland Cancer

    MedlinePlus

    ... either benign or malignant. Benign tumors aren't cancer. Malignant ones are. Most adrenal gland tumors are ... and may not require treatment. Malignant adrenal gland cancers are uncommon. Types of tumors include Adrenocortical carcinoma - ...

  2. Mechanical performance comparison between RotaFlow and CentriMag centrifugal blood pumps in an adult ECLS model.

    PubMed

    Yulong Guan; Xiaowei Su; McCoach, Robert; Kunselman, Allen; El-Banayosy, Aly; Undar, Akif

    2010-03-01

    Centrifugal blood pumps have been widely adopted in conventional adult cardiopulmonary bypass and circulatory assist procedures. Different brands of centrifugal blood pumps incorporate distinct designs which affect pump performance. In this adult extracorporeal life support (ECLS) model, the performances of two brands of centrifugal blood pump (RotaFlow blood pump and CentriMag blood pump) were compared. The simulated adult ECLS circuit used in this study included a centrifugal blood pump, Quadrox D membrane oxygenator and Sorin adult ECLS tubing package. A Sorin Cardiovascular(R) VVR(R) 4000i venous reservoir (Sorin S.p.A., Milan, Italy) with a Hoffman clamp served as a pseudo-patient. The circuit was primed with 900ml heparinized human packed red blood cells and 300ml lactated Ringer's solution (total volume 1200 ml, corrected hematocrit 40%). Trials were conducted at normothermia (36 degrees C). Performance, including circuit pressure and flow rate, was measured for every setting analyzed. The shut-off pressure of the RotaFlow was higher than the CentriMag at all measurement points given the same rotation speed (p < 0.0001). The shut-off pressure differential between the two centrifugal blood pumps was significant and increased given higher rotation speeds (p < 0.0001). The RotaFlow blood pump has higher maximal flow rate (9.08 +/- 0.01L/min) compared with the CentriMag blood pump (8.37 +/- 0.02L/min) (p < 0.0001). The blood flow rate differential between the two pumps when measured at the same revolutions per minute (RPM) ranged from 1.64L/min to 1.73L/min. The results obtained in this experiment demonstrate that the RotaFlow has a higher shut-off pressure (less retrograde flow) and maximal blood flow rate than the CentriMag blood pump. Findings support the conclusion that the RotaFlow disposable pump head has a better mechanical performance than the CentriMag. In addition, the RotaFlow disposable pump is 20-30 times less expensive than the CentriMag.

  3. Successful catheter ablation of a left anterior accessory pathway from the non-coronary cusp of the aortic valve.

    PubMed

    Laranjo, Sérgio; Oliveira, Mário; Trigo, Conceição

    2015-08-01

    Left anterior accessory pathways are considered to be rare findings. Catheter ablation of accessory pathways in this location remains a challenging target, and few reports about successful ablation of these accessory pathways are available. We describe our experience regarding a case of a manifest left anterior accessory pathway ablation using radiofrequency energy at the junction of the left coronary cusp with the non-coronary cusp.

  4. Morphological Features of the Porcine Lacrimal Gland and Its Compatibility for Human Lacrimal Gland Xenografting

    PubMed Central

    Gaffling, Simone; Asano, Nagayoshi; Hampel, Ulrike; Garreis, Fabian; Hornegger, Joachim; Paulsen, Friedrich

    2013-01-01

    In this study, we present first data concerning the anatomical structure, blood supply and location of the lacrimal gland of the pig. Our data indicate that the porcine lacrimal gland may serve as a potential xenograft candidate in humans or as an animal model for engineering of a bioartificial lacrimal gland tissue construct for clinical application. For this purpose, we used different macroscopic preparation techniques and digital reconstruction of the histological gland morphology to gain new insights and important information concerning the feasibility of a lacrimal gland transplantation from pig to humans in general. Our results show that the lacrimal gland of the pig reveals a lot of morphological similarities to the analogous human lacrimal gland and thus might be regarded as a xenograft in the future. This is true for a similar anatomical location within the orbit as well as for the feeding artery supply to the organ. Functional differences concerning the composition of the tear fluid, due to a different secretory unit distribution within the gland tissue will, however, be a challenge in future investigations. PMID:24069265

  5. Morphological features of the porcine lacrimal gland and its compatibility for human lacrimal gland xenografting.

    PubMed

    Henker, Robert; Scholz, Michael; Gaffling, Simone; Asano, Nagayoshi; Hampel, Ulrike; Garreis, Fabian; Hornegger, Joachim; Paulsen, Friedrich

    2013-01-01

    In this study, we present first data concerning the anatomical structure, blood supply and location of the lacrimal gland of the pig. Our data indicate that the porcine lacrimal gland may serve as a potential xenograft candidate in humans or as an animal model for engineering of a bioartificial lacrimal gland tissue construct for clinical application. For this purpose, we used different macroscopic preparation techniques and digital reconstruction of the histological gland morphology to gain new insights and important information concerning the feasibility of a lacrimal gland transplantation from pig to humans in general. Our results show that the lacrimal gland of the pig reveals a lot of morphological similarities to the analogous human lacrimal gland and thus might be regarded as a xenograft in the future. This is true for a similar anatomical location within the orbit as well as for the feeding artery supply to the organ. Functional differences concerning the composition of the tear fluid, due to a different secretory unit distribution within the gland tissue will, however, be a challenge in future investigations.

  6. Comparison of MagNA Pure 96, Chemagic MSM1, and QIAamp MinElute for hepatitis B virus nucleic acid extraction.

    PubMed

    Kang, Seong-Ho; Lee, Eun Hee; Park, Geon; Jang, Sook Jin; Moon, Dae Soo

    2012-01-01

    This study was designed to compare two automated systems and one manual system for hepatitis B virus (HBV) nucleic acid extraction. The two automated systems were the MagNA Pure 96 system (Roche Applied Science, Manheim, Germany) and the Chemagic system (Chemagen, Baesweiler, Germany), and the manual system was the QIAamp system (Qiagen, Hilden, Germany). Sixty-eight samples that were within the detection range of the Cobas Ampliprep/Cobas TaqMan (CAP/CTM) platform (Roche Molecular Systems, Manheim, Germany) were selected. Extracted viral nucleic acids from the three systems were quantified using an AccuPower HBV Quantitative PCR kit (Bioneer, Daejon, Korea). The MagNA Pure 96 system and QIAamp system did not detect viral loads in one sample. The Chemagic system did not detect low viral loads in nine samples (range, 26-290 IU/mL by the CAP/CTM platform). Comparisons of the viral loads of the samples from the MagNA Pure 96 system, the Chemagic system, and the QIAamp system with those from the CAP/CTM platform yielded correlation coefficients of 0.977, 0.914, and 0.967, respectively. Comparisons of the MagNA Pure 96 system and the Chemagic system with the QIAamp system yielded correlation coefficients of 0.987 and 0.939, respectively. The MagNA Pure 96 system demonstrated better performance than the Chemagic system for HBV nucleic acid extraction. The MagNA Pure 96 system demonstrated comparable performance with the QIAamp system.

  7. Mammotome-Assisted Liposuction: A Novel Technique for Accessory Breasts.

    PubMed

    Tang, Xin

    2017-06-01

    Due to its minimally invasive and highly precise nature, the mammotome, a vacuum-assisted breast biopsy device, has proven effective for the treatment of benign breast lesions. Taking advantage of both liposuction and the mammotome, we utilized the mammotome device for the excision of accessory breasts. Between July 2010 and June 2014, 16 patients with accessory breasts received mammotome-assisted liposuction. After adipose was removed using this procedure, the mammotome system was used to excise the fibro-glandular tissue in accessory breasts under ultrasound monitoring. All patients were satisfied with their appearance after surgery. A single 5-mm incision, which was well hidden in the axillary skin folds and allowed for restoration, provided an aesthetically pleasing contour to the axilla. Mammotome-assisted liposuction is a new approach that can be used to excise both adipose and fibro-glandular breast tissue simultaneously with a minimal incision, and provides a favorable contour to the axilla. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  8. Accessory hepatic vein complicating extra-cardiac total cavopulmonary connection.

    PubMed

    Yoshii, Shinpei; Suzuki, Shoji; Osawa, Hiroshi; Hosaka, Shigeru; Honda, Yoshihiro; Abraham, Samuel J K; Tada, Yusuke; Sugiyama, Hisashi; Tan, Tetsushi; Kadono, Toshie; Hoshiai, Minako; Komai, Takayuki

    2002-04-01

    We encountered unexpected, severe hypoxia after the right heart bypass operation in a patient with isomerism. A 2-year-old girl with polysplenia had a complex cardiac anomaly consisting of a single atrium, single ventricle, pulmonary stenosis, absence of the right superior vena cava, hemiazygos continuation of the left inferior vena cava, and d-malposition of the great arteries. After a total cavopulmonary shunt, we performed an extra-cardiac total cavo-pulmonary connection with a 14 mm tube graft. The postoperative course was complicated by severe hypoxia. Angiography performed 20 days after the operation showed that contrast medium in the conduit poured into the hepatic vein, and through the intrahepatic communications, it passed into a left-sided accessory hepatic vein, which was connected directly to the left side of the aspect of the atrium. As the intrahepatic communication was adequate, we ligated the accessory hepatic vein within the pericardial cavity. The SpO2 returned to normal and no hepatic dysfunction was detected. We conclude that surgeons performing extra-cardiac total cavopulmonary connection need to pay closer attention to the possibility that an accessory hepatic vein might exist.

  9. Accessory carpal bone luxation in two gray wolves (Canis lupus).

    PubMed

    Keller, Dominique L; Ellison, Michelle; Clyde, Victoria L; Wallace, Roberta S

    2012-09-01

    Two sibling male castrated gray wolves (Canis lupus) developed acute onset right forelimb lameness, one at 8 and the other at 11 yr of age. In both cases, the right carpus was swollen, carpal hyperextension was notable, and the wolves exhibited significant intermittent lameness of the affected limb. Radiographs revealed right accessory carpal bone luxation in both cases, with type III fracture of the accessory carpal bone in one wolf. Although carpal bone luxation in domestic dogs is frequently treated surgically, conservative medical management resolved the lameness in both wolves with no further complications.

  10. 21 CFR 872.6010 - Abrasive device and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories... crowns. The device is attached to a shank that is held by a handpiece. The device includes the abrasive...

  11. 21 CFR 872.6010 - Abrasive device and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories... crowns. The device is attached to a shank that is held by a handpiece. The device includes the abrasive...

  12. 21 CFR 872.6010 - Abrasive device and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories... crowns. The device is attached to a shank that is held by a handpiece. The device includes the abrasive...

  13. 21 CFR 872.6010 - Abrasive device and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories... crowns. The device is attached to a shank that is held by a handpiece. The device includes the abrasive...

  14. 21 CFR 872.6010 - Abrasive device and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories... crowns. The device is attached to a shank that is held by a handpiece. The device includes the abrasive...

  15. Algal Accessory Pigment Detection Using AVIRIS Image-Derived Spectral Radiance Data

    NASA Technical Reports Server (NTRS)

    Richardson, Laurie L.; Ambrosia, Vincent G.

    1996-01-01

    Visual and derivative analyses of AVIRIS spectral data can be used to detect algal accessory pigments in aquatic communities. This capability extends the use of remote sensing for the study of aquatic ecosystems by allowing detection of taxonomically significant pigment signatures which yield information about the type of algae present. Such information allows remote sensing-based assessment of aquatic ecosystem health, as in the detection of nuisance blooms of cyanobacteria or toxic blooms of dinoflagellates. Remote sensing of aquatic systems has traditionally focused on quantification of chlorophyll a, a photoreactive (and light-harvesting) pigment which is common to all algae as well as cyanobacteria (bluegreen algae). Due to the ubiquitousness of this pigment within algae, chl a is routinely measured to estimate algal biomass both during ground-truthing and using various airborne or satellite based sensors, including AVIRIS. Within the remote sensing and aquatic sciences communities, ongoing research has been performed to detect algal accessory pigments for assessment of algal population composition. This research is based on the fact that many algal accessory pigments are taxonomically significant, and all are spectrally unique. Aquatic scientists have been refining pigment analysis techniques, primarily high performance liquid chromatography, or HPLC, to detect specific pigments as a time-saving alternative to individual algal cell identifications and counts. Remote sensing scientists are investigating the use of pigment signatures to construct pigment libraries analogous to mineral spectral libraries used in geological remote sensing applications. The accessory pigment approach has been used successfully in remote sensing using data from the Thematic Mapper, low-altitude, multiple channel scanners, field spectroradiometers and the AVIRIS hyperspectral scanner. Due to spectral and spatial resolution capabilities, AVIRIS is the sensor of choice for such

  16. Salivary Gland Cancer

    MedlinePlus

    ... contains antibodies that can kill germs. Salivary gland cancer is a type of head and neck cancer. It is rare. It may not cause any ... pain in your face Doctors diagnose salivary gland cancer using a physical exam, imaging tests, and a ...

  17. 49 CFR 390.17 - Additional equipment and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... equipment and accessories, not inconsistent with or prohibited by this subchapter, provided such equipment... are used. [53 FR 18052, May 19, 1988, as amended at 60 FR 38744, July 28, 1995. Redesignated at 65 FR...

  18. Expression profiles of aquaporins in rat conjunctiva, cornea, lacrimal gland and Meibomian gland.

    PubMed

    Yu, Dongfang; Thelin, William R; Randell, Scott H; Boucher, Richard C

    2012-10-01

    The aim of the study was to elucidate aquaporin (AQP) family member mRNA expression and protein expression/localization in the rat lacrimal functional unit. The mRNA expression of all rat AQPs (AQP0-9, 11-12) in palpebral, fornical, and bulbar conjunctiva, cornea, lacrimal gland, and Meibomian gland was measured by Reverse Transcriptase-Polymerase Chain Reaction (RT-PCR) and real time RT-PCR. Antibodies against AQP1, 3, 4, 5, 9, and 11 were used in Western blotting and immunohistochemistry to determine protein expression and distribution. Our study demonstrated characteristic AQP expression profiles in rat ocular tissues. AQP1, 3, 4, 5, 8, 9, 11, and 12 mRNA were detected in conjunctiva. AQP0, 1, 2, 3, 4, 5, 6, 11, and 12 mRNA were expressed in cornea. AQP0, 1, 2, 3, 4, 5, 7, 8, and 11 mRNA were detected in lacrimal gland. AQP1, 3, 4, 5, 7, 8, 9, 11, and 12 mRNA were identified in Meibomian gland. By Western blot, AQP1, 3, 5, and 11 were detected in conjunctiva; AQP1, 3, 5, and 11 were identified in cornea; AQP1, 3, 4, 5, and 11 were detected in lacrimal gland; and AQP1, 3, 4, 5, 9, and 11 were present in Meibomian gland. Immunohistochemistry localized AQPs to distinct sites in the various tissues. This study rigorously analyzed AQPs expression and localization in rat conjunctiva, cornea, lacrimal gland, and Meibomian gland tissues. Our findings provide a comprehensive platform for further investigation into the physiological or pathophysiological relevance of AQPs in ocular surface. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. The nucleotide composition of microbial genomes indicates differential patterns of selection on core and accessory genomes.

    PubMed

    Bohlin, Jon; Eldholm, Vegard; Pettersson, John H O; Brynildsrud, Ola; Snipen, Lars

    2017-02-10

    The core genome consists of genes shared by the vast majority of a species and is therefore assumed to have been subjected to substantially stronger purifying selection than the more mobile elements of the genome, also known as the accessory genome. Here we examine intragenic base composition differences in core genomes and corresponding accessory genomes in 36 species, represented by the genomes of 731 bacterial strains, to assess the impact of selective forces on base composition in microbes. We also explore, in turn, how these results compare with findings for whole genome intragenic regions. We found that GC content in coding regions is significantly higher in core genomes than accessory genomes and whole genomes. Likewise, GC content variation within coding regions was significantly lower in core genomes than in accessory genomes and whole genomes. Relative entropy in coding regions, measured as the difference between observed and expected trinucleotide frequencies estimated from mononucleotide frequencies, was significantly higher in the core genomes than in accessory and whole genomes. Relative entropy was positively associated with coding region GC content within the accessory genomes, but not within the corresponding coding regions of core or whole genomes. The higher intragenic GC content and relative entropy, as well as the lower GC content variation, observed in the core genomes is most likely associated with selective constraints. It is unclear whether the positive association between GC content and relative entropy in the more mobile accessory genomes constitutes signatures of selection or selective neutral processes.

  20. Characterization of human pineal gland proteome.

    PubMed

    Yelamanchi, Soujanya D; Kumar, Manish; Madugundu, Anil K; Gopalakrishnan, Lathika; Dey, Gourav; Chavan, Sandip; Sathe, Gajanan; Mathur, Premendu P; Gowda, Harsha; Mahadevan, Anita; Shankar, Susarla K; Prasad, T S Keshava

    2016-11-15

    The pineal gland is a neuroendocrine gland located at the center of the brain. It is known to regulate various physiological functions in the body through secretion of the neurohormone melatonin. Comprehensive characterization of the human pineal gland proteome has not been undertaken to date. We employed a high-resolution mass spectrometry-based approach to characterize the proteome of the human pineal gland. A total of 5874 proteins were identified from the human pineal gland in this study. Of these, 5820 proteins were identified from the human pineal gland for the first time. Interestingly, 1136 proteins from the human pineal gland were found to contain a signal peptide domain, which indicates the secretory nature of these proteins. An unbiased global proteomic profile of this biomedically important organ should benefit molecular research to unravel the role of the pineal gland in neuropsychiatric and neurodegenerative diseases.

  1. Giant accessory breast: a rare occurrence reported, with a review of the literature.

    PubMed

    Hiremath, Bharati; Subramaniam, Narayana; Chandrashekhar, Nayan

    2015-11-05

    Polymastia, or the presence of supranumerary breasts, occurs in 2-6% of the female population, the spectrum of the disorder ranging between a small mole and a fully functional ectopic breast. They are often asymptomatic but require treatment when symptomatic or if they harbour malignancy. We present a case of a 41-year-old woman with an accessory breast in the left inframammary fold, which increased in size over the decade following her first pregnancy, to reach a size almost three times that of her right breast. Preoperative fine-needle aspiration and ultrasound was suggestive of accessory breast tissue, distinct from the left breast. Intraoperatively, a 14×10×8 cm accessory breast was found in the inframammary fold, distinct from the left breast and having an accessory nipple areola complex as well. A simple mastectomy was performed with trimming and rotation of the inframammary flap. The patient was happy with the cosmetic outcome. This article also reviews the literature and covers classification of polymastia, diagnostic complexities and challenges associated with surgery. 2015 BMJ Publishing Group Ltd.

  2. Giant accessory breast: a rare occurrence reported, with a review of the literature

    PubMed Central

    Hiremath, Bharati; Subramaniam, Narayana; Chandrashekhar, Nayan

    2015-01-01

    Polymastia, or the presence of supranumerary breasts, occurs in 2–6% of the female population, the spectrum of the disorder ranging between a small mole and a fully functional ectopic breast. They are often asymptomatic but require treatment when symptomatic or if they harbour malignancy. We present a case of a 41-year-old woman with an accessory breast in the left inframammary fold, which increased in size over the decade following her first pregnancy, to reach a size almost three times that of her right breast. Preoperative fine-needle aspiration and ultrasound was suggestive of accessory breast tissue, distinct from the left breast. Intraoperatively, a 14×10×8 cm accessory breast was found in the inframammary fold, distinct from the left breast and having an accessory nipple areola complex as well. A simple mastectomy was performed with trimming and rotation of the inframammary flap. The patient was happy with the cosmetic outcome. This article also reviews the literature and covers classification of polymastia, diagnostic complexities and challenges associated with surgery. PMID:26542818

  3. Investigating the laser heating of underdense plasmas at conditions relevant to MagLIF

    NASA Astrophysics Data System (ADS)

    Harvey-Thompson, Adam

    2015-11-01

    The magnetized Liner Inertial Fusion (MagLIF) scheme has achieved thermonuclear fusion yields on Sandia's Z Facility by imploding a cylindrical liner filled with D2 fuel that is preheated with a multi-kJ laser and pre-magnetized with an axial field Bz = 10 T. The challenge of fuel preheating in MagLIF is to deposit several kJ's of energy into an underdense (ne/ncrit<0.1) fusion fuel over ~ 10 mm target length efficiently and without introducing contaminants that could contribute to unacceptable radiative losses during the implosion. Very little experimental work has previously been done to investigate laser heating of gas at densities, scale lengths, modest intensities (Iλ2 ~ 1014 watts- μm2 /cm2) and magnetization parameters (ωceτe ~ 10) necessary for MagLIF. In particular, magnetization of the preheated plasma suppresses electron thermal conduction, which can modify laser energy coupling. Providing an experimental dataset in this regime is essential to not only understand the dynamics of a MagLIF implosion and stagnation, but also to validate magnetized transport models and better understand the physics of laser propagation in magnetized plasmas. In this talk, we present data and analysis of several experiments conducted at OMEGA-EP and at Z to investigate laser propagation and plasma heating in underdense D2 plasmas under a range of conditions, including densities (ne = 0.05-0.1 nc) and magnetization parmaters (ωceτe ~ 0-10). The results show differences in the electron temperature of the heated plasma and the velocity of the laser burn wave with and without an applied magnetic field. We will show comparisons of these experimental results to 2D and 3D HYDRA simulations, which show that the effect of the magnetic field on the electron thermal conduction needs to be taken into account when modeling laser preheat. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the National Nuclear Security Administration

  4. 21 CFR 876.4300 - Endoscopic electrosurgical unit and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... accessories is a device used to perform electrosurgical procedures through an endoscope. This generic type of device includes the electrosurgical generator, patient plate, electric biopsy forceps, electrode...

  5. Plasma exchanges for severe acute neurological deterioration in patients with IgM anti-myelin-associated glycoprotein (anti-MAG) neuropathy.

    PubMed

    Baron, M; Lozeron, P; Harel, S; Bengoufa, D; Vignon, M; Asli, B; Malphettes, M; Parquet, N; Brignier, A; Fermand, J P; Kubis, N; Arnulf, Bertrand

    2017-06-01

    Monoclonal IgM anti-myelin-associated glycoprotein (MAG) antibody-related peripheral neuropathy (anti-MAG neuropathy) is predominantly a demyelinating sensory neuropathy with ataxia and distal paresthesia. The clinical course of anti-MAG neuropathy is usually slowly progressive making difficult the identification of clear criteria to start a specific treatment. Although no consensus treatment is yet available, a rituximab-based regimen targeting the B-cell clone producing the monoclonal IgM may be proposed, alone or in combination with alkylating agents or purine analogs. However, in some rare cases, an acute and severe neurological deterioration can occur in few days leading to a rapid loss of autonomy. In these cases, a treatment rapidly removing the monoclonal IgM from the circulation might be useful before initiating a specific therapy. We report successful treatment with plasma exchanges (PE) in four patients presenting with acute neurological deterioration. PE allowed a dramatic and rapid neurological improvement in all patients. PE are safe and may be useful at the initial management of these cases of anti-MAG neuropathy.

  6. A New MIC1-MAG1 Recombinant Chimeric Antigen Can Be Used Instead of the Toxoplasma gondii Lysate Antigen in Serodiagnosis of Human Toxoplasmosis

    PubMed Central

    Holec-Gąsior, Lucyna; Ferra, Bartłomiej; Drapała, Dorota; Lautenbach, Dariusz

    2012-01-01

    This study presents an evaluation of the MIC1 (microneme protein 1)-MAG1 (matrix antigen 1) Toxoplasma gondii recombinant chimeric antigen for the serodiagnosis of human toxoplasmosis for the first time. The recombinant MIC1-MAG1 antigen was obtained as a fusion protein containing His tags at the N- and C-terminal ends using an Escherichia coli expression system. After purification by metal affinity chromatography, the chimeric protein was tested for usefulness in an enzyme-linked immunosorbent assay (ELISA) for the detection of anti-T. gondii immunoglobulin G (IgG). One hundred ten sera from patients at different stages of infection and 40 sera from seronegative patients were examined. The results obtained for the MIC1-MAG1 chimeric antigen were compared with those of IgG ELISAs using a Toxoplasma lysate antigen (TLA), a combination of recombinant antigens (rMIC1ex2-rMAG1) and single recombinant proteins (rMIC1ex2 and rMAG1). The sensitivity of the IgG ELISA calculated from all of the positive serum samples was similar for the MIC1-MAG1 chimeric antigen (90.8%) and the TLA (91.8%), whereas the sensitivities of the other antigenic samples used were definitely lower, at 69.1% for the mixture of antigens, 75.5% for the rMIC1ex2, and 60% for rMAG1. This study demonstrates that the MIC1-MAG1 recombinant chimeric antigen can be used instead of the TLA in the serodiagnosis of human toxoplasmosis. PMID:22116686

  7. The scolopidial accessory organs and Nebenorgans in orthopteroid insects: Comparative neuroanatomy, mechanosensory function, and evolutionary origin.

    PubMed

    Strauß, Johannes

    2017-11-01

    Scolopidial sensilla in insects often form large sensory organs involved in proprioception or exteroception. Here the knowledge on Nebenorgans and accessory organs, two organs consisting of scolopidial sensory cells, is summarised. These organs are present in some insects which are model organisms for the physiology of mechanosensory systems (cockroaches and tettigoniids). Recent comparative studies documented the accessory organ in several taxa of Orthoptera (including tettigoniids, cave crickets, Jerusalem crickets) and the Nebenorgan in related insects (Mantophasmatodea). The accessory organ or Nebenorgan is usually a small organ of 8-15 sensilla located in the posterior leg tibia of all leg pairs. The physiological properties of the accessory organs and Nebenorgans are so far largely unknown. Taking together neuroanatomical and electrophysiological data from disparate taxa, there is considerable evidence that the accessory organ and Nebenorgan are vibrosensitive. They thus complement the larger vibrosensitive subgenual organ in the tibia. This review summarises the comparative studies of these sensory organs, in particular the arguments and criteria for the homology of the accessory organ and Nebenorgan among orthopteroid insects. Different scenarios of repeated evolutionary origins or losses of these sensory organs are discussed. Neuroanatomy allows to distinguish individual sensory organs for analysis of sensory physiology, and to infer scenarios of sensory evolution. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Accessories modifying based on plastic waste of shampoo bottle as home economic product

    NASA Astrophysics Data System (ADS)

    Setyowati, Erna; Sukesi, Siti

    2018-03-01

    Plastic is a waste that can not decompose by the soil and if its left without a good handling can pollute the environment. Plastic waste needs processing by the recycle bottles principle. Shampoo bottle is one of plastic waste with high density polyethylene type (HDPE). One of the innovation to recycling shampoo bottles waste into the new products whichbeneficially and aestheticallyform by engineered the buns accesories. Accessories are one of the tools used by most women, in the form of trinkets or ornaments which ajusted to the trend to beautify the look. Accessories from shampoo bottle waste can be obtained from household waste, beauty salon and the beauty program study by inculcating human beings' behavior by transforming waste into blessing while also increasing family income. Technique of making its by compiling through improvement of panelist team. The goal of this research is to engineering theaccessories based on shampoo bottle waste as home economics. The method are using experiment, observation and documentation, analysis using descriptive. The results obtained from the overall sensory test averaged at 93%, while the favored test averaged at 85.5%. The product can be ordered according to the desired design, but it takes a long time. Therefore accessories engineering from shampoo bottles waste-based can be used as home economics. The production of shampoo bottles waste-based accessories should improved its quality and quantity, to be marketed through the community, by the cooperation with accessories and bun craftsmen.

  9. 21 CFR 884.1690 - Hysteroscope and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... specialized instrument or device delivery system; do not have adapters, connectors, channels, or do not have... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hysteroscope and accessories. 884.1690 Section 884.1690 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...

  10. 21 CFR 884.1690 - Hysteroscope and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... specialized instrument or device delivery system; do not have adapters, connectors, channels, or do not have... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hysteroscope and accessories. 884.1690 Section 884.1690 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...

  11. 21 CFR 884.1690 - Hysteroscope and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... specialized instrument or device delivery system; do not have adapters, connectors, channels, or do not have... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hysteroscope and accessories. 884.1690 Section 884.1690 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...

  12. 21 CFR 884.1690 - Hysteroscope and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... specialized instrument or device delivery system; do not have adapters, connectors, channels, or do not have... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hysteroscope and accessories. 884.1690 Section 884.1690 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...

  13. 21 CFR 884.1690 - Hysteroscope and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... specialized instrument or device delivery system; do not have adapters, connectors, channels, or do not have... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hysteroscope and accessories. 884.1690 Section 884.1690 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...

  14. Introducing a New Interface for the Online MagIC Database by Integrating Data Uploading, Searching, and Visualization

    NASA Astrophysics Data System (ADS)

    Jarboe, N.; Minnett, R.; Constable, C.; Koppers, A. A.; Tauxe, L.

    2013-12-01

    The Magnetics Information Consortium (MagIC) is dedicated to supporting the paleomagnetic, geomagnetic, and rock magnetic communities through the development and maintenance of an online database (http://earthref.org/MAGIC/), data upload and quality control, searches, data downloads, and visualization tools. While MagIC has completed importing some of the IAGA paleomagnetic databases (TRANS, PINT, PSVRL, GPMDB) and continues to import others (ARCHEO, MAGST and SECVR), further individual data uploading from the community contributes a wealth of easily-accessible rich datasets. Previously uploading of data to the MagIC database required the use of an Excel spreadsheet using either a Mac or PC. The new method of uploading data utilizes an HTML 5 web interface where the only computer requirement is a modern browser. This web interface will highlight all errors discovered in the dataset at once instead of the iterative error checking process found in the previous Excel spreadsheet data checker. As a web service, the community will always have easy access to the most up-to-date and bug free version of the data upload software. The filtering search mechanism of the MagIC database has been changed to a more intuitive system where the data from each contribution is displayed in tables similar to how the data is uploaded (http://earthref.org/MAGIC/search/). Searches themselves can be saved as a permanent URL, if desired. The saved search URL could then be used as a citation in a publication. When appropriate, plots (equal area, Zijderveld, ARAI, demagnetization, etc.) are associated with the data to give the user a quicker understanding of the underlying dataset. The MagIC database will continue to evolve to meet the needs of the paleomagnetic, geomagnetic, and rock magnetic communities.

  15. Salivary Gland Secretion.

    ERIC Educational Resources Information Center

    Dorman, H. L.; And Others

    1981-01-01

    Describes materials and procedures for an experiment utilizing a live dog to demonstrate: (1) physiology of the salivary gland; (2) parasympathetic control of the salivary gland; (3) influence of varying salivary flow rates on sodium and potassium ions, osmolarity and pH; and (4) salivary secretion as an active process. (DS)

  16. Progress in the clinical imaging research of bone diseases on ankle and foot sesamoid bones and accessory ossicles

    PubMed Central

    Li, Xiaozhong; Shi, Lenian; Liu, Taiyun; Wang, Lin

    2012-01-01

    Summary Sesamoid bones and accessory ossicles are research focuses of foot and ankle surgery. Pains of the foot and ankle are related to sesamoid bones and accessory ossicles. The specific anatomical and functional relationship of sesamoid bones and accessory ossicles can cause such bone diseases as the dislocation of sesamoid bones and accessory bones, infection, inflammation and necrosis of sesamoid bones, cartilage softening, tenosynovitis of sesamoid bones and the sesamoid bone syndrome. However, these bone diseases are often misdiagnosed or mistreated. In patients with trauma history, relevant diseases of sesamoid bones and accessory ossicles as above mentioned are highly probable to be misdiagnosed as avulsion fractures. In such cases, radiographic findings may provide a basis for clinical diagnosis. PMID:25343083

  17. Salivary gland diseases in children

    PubMed Central

    Iro, Heinrich; Zenk, Johannes

    2014-01-01

    Salivary gland diseases in children are rare, apart from viral-induced diseases. Nevertheless, it is essential for the otolaryngologist to recognize these uncommon findings in children and adolescents and to diagnose and initiate the proper treatment. The present work provides an overview of the entire spectrum of congenital and acquired diseases of the salivary glands in childhood and adolescence. The current literature was reviewed and the results discussed and summarized. Besides congenital diseases of the salivary glands in children, the main etiologies of viral and bacterial infections, autoimmune diseases and tumors of the salivary glands were considered. In addition to the known facts, new developments in diagnostics, imaging and therapy, including sialendoscopy in obstructive diseases and chronic recurrent juvenile sialadenitis were taken into account. In addition, systemic causes of salivary gland swelling and the treatment of sialorrhoea were discussed. Although salivary gland diseases in children are usually included in the pathology of the adult, they differ in their incidence and some­times in their symptoms. Clinical diagnostics and especially the surgical treatment are influenced by a stringent indications and a less invasive strategy. Due to the rarity of tumors of the salivary glands in children, it is recommended to treat them in a specialized center with greater surgical experience. Altogether the knowledge of the differential diagnoses in salivary gland diseases in children is important for otolaryngologists, to indicate the proper therapeutic approach. PMID:25587366

  18. 77 FR 22802 - Certain Handbags, Luggage, Accessories, and Packaging Thereof; Determination Not To Review an...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-17

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-754] Certain Handbags, Luggage, Accessories, and Packaging Thereof; Determination Not To Review an Initial Determination Granting Complainant... importation of certain handbags, luggage, accessories, and packaging thereof by reason of infringement of U.S...

  19. Three-dimensional finite element analysis on canine teeth distalization by different accessories of bracket-free invisible orthodontics technology

    NASA Astrophysics Data System (ADS)

    Xu, Nuo; Lei, Xue; Yang, Xiaoli; Li, Xinhui; Ge, Zhenlin

    2018-04-01

    Objective: to compare canine tooth stress distribution condition during maxillary canine tooth distalization by different accessories of bracket-free invisible orthodontics technology after removal of maxillary first premolar, and provide basis for clinical design of invisible orthodontics technology. Method: CBCT scanning image of a patient with individual normal occlusion was adopted, Mimics, Geomagic and ProlE software were used for establishing three-dimensional models of maxilla, maxillary dentition, parodontium, invisible orthodontics appliance and accessories, ANSYS WORKBENCH was utilized as finite element analysis tools for analyzing stress distribution and movement pattern of canine tooth and parodontium when canine tooth was equipped with power arm and vertical rectangle accessory. Meanwhile, canine tooth none-accessory design group was regarded as a control. Result: teeth had even bistal surface stress distribution in the power arm group; stress was concentrated on distal tooth neck, and the stress was gradually deviated to mesial-labial side and distal lingual side in vertical rectangle group and none-accessory group. Conclusion: teeth tend to move as a whole in the Power arm group, vertical rectangle group has lower tooth gradient compared with the none-accessory group, teeth are inclined for movement in the none-accessory group, and canine teeth tend to rotate to the distal lingual side.

  20. Thermomechanical milling of accessory lithics in volcanic conduits

    NASA Astrophysics Data System (ADS)

    Campbell, Michelle E.; Russell, James K.; Porritt, Lucy A.

    2013-09-01

    Accessory lithic clasts recovered from pyroclastic deposits commonly result from the failure of conduit wall rocks, and represent an underutilized resource for constraining conduit processes during explosive volcanic eruptions. The morphological features of lithic clasts provide distinctive 'textural fingerprints' of processes that have reshaped them during transport in the conduit. Here, we present the first study focused on accessory lithic clast morphology and show how the shapes and surfaces of these accessory pyroclasts can inform on conduit processes. We use two main types of accessory lithic clasts from pyroclastic fallout deposits of the 2360 B.P. subplinian eruption of Mount Meager, British Columbia, as a case study: (i) rough and subangular dacite clasts, and (ii) variably rounded and smoothed monzogranite clasts. The quantitative morphological data collected on these lithics include: mass, volume, density, 2-D image analysis of convexity (C), and 3-D laser scans for sphericity (Ψ) and smoothness (S). Shaping and comminution (i.e. milling) of clasts within the conduit are ascribed to three processes: (1) disruptive fragmentation due to high-energy impacts between clasts or between clasts and conduit walls, (2) ash-blasting of clasts suspended within the volcanic flux, and (3) thermal effects. We use a simplified conduit eruption model to predict ash-blasting velocities and lithic residence times as a function of clast size and source depth, thereby constraining the lithic milling processes. The extent of shape and surface modification (i.e. rounding and honing) is directly proportional to clast residence times within the conduit prior to evacuation. We postulate that the shallow-seated dacite clasts remain subangular and rough due to short (<2 min) residence times, whereas monzogranite clasts are much more rounded and smoothed due to deeper source depths and consequently longer residence times (up to ˜1 h). Larger monzogranite clasts are smoother than

  1. Accessory genes confer a high replication rate to virulent feline immunodeficiency virus.

    PubMed

    Troyer, Ryan M; Thompson, Jesse; Elder, John H; VandeWoude, Sue

    2013-07-01

    Feline immunodeficiency virus (FIV) is a lentivirus that causes AIDS in domestic cats, similar to human immunodeficiency virus (HIV)/AIDS in humans. The FIV accessory protein Vif abrogates the inhibition of infection by cat APOBEC3 restriction factors. FIV also encodes a multifunctional OrfA accessory protein that has characteristics similar to HIV Tat, Vpu, Vpr, and Nef. To examine the role of vif and orfA accessory genes in FIV replication and pathogenicity, we generated chimeras between two FIV molecular clones with divergent disease potentials: a highly pathogenic isolate that replicates rapidly in vitro and is associated with significant immunopathology in vivo, FIV-C36 (referred to here as high-virulence FIV [HV-FIV]), and a less-pathogenic strain, FIV-PPR (referred to here as low-virulence FIV [LV-FIV]). Using PCR-driven overlap extension, we produced viruses in which vif, orfA, or both genes from virulent HV-FIV replaced equivalent genes in LV-FIV. The generation of these chimeras is more straightforward in FIV than in primate lentiviruses, since FIV accessory gene open reading frames have very little overlap with other genes. All three chimeric viruses exhibited increased replication kinetics in vitro compared to the replication kinetics of LV-FIV. Chimeras containing HV-Vif or Vif/OrfA had replication rates equivalent to those of the virulent HV-FIV parental virus. Furthermore, small interfering RNA knockdown of feline APOBEC3 genes resulted in equalization of replication rates between LV-FIV and LV-FIV encoding HV-FIV Vif. These findings demonstrate that Vif-APOBEC interactions play a key role in controlling the replication and pathogenicity of this immunodeficiency-inducing virus in its native host species and that accessory genes act as mediators of lentiviral strain-specific virulence.

  2. The Magnetics Information Consortium (MagIC) Online Database: Uploading, Searching and Visualizing Paleomagnetic and Rock Magnetic Data

    NASA Astrophysics Data System (ADS)

    Minnett, R.; Koppers, A.; Tauxe, L.; Constable, C.; Pisarevsky, S. A.; Jackson, M.; Solheid, P.; Banerjee, S.; Johnson, C.

    2006-12-01

    The Magnetics Information Consortium (MagIC) is commissioned to implement and maintain an online portal to a relational database populated by both rock and paleomagnetic data. The goal of MagIC is to archive all measurements and the derived properties for studies of paleomagnetic directions (inclination, declination) and intensities, and for rock magnetic experiments (hysteresis, remanence, susceptibility, anisotropy). MagIC is hosted under EarthRef.org at http://earthref.org/MAGIC/ and has two search nodes, one for paleomagnetism and one for rock magnetism. Both nodes provide query building based on location, reference, methods applied, material type and geological age, as well as a visual map interface to browse and select locations. The query result set is displayed in a digestible tabular format allowing the user to descend through hierarchical levels such as from locations to sites, samples, specimens, and measurements. At each stage, the result set can be saved and, if supported by the data, can be visualized by plotting global location maps, equal area plots, or typical Zijderveld, hysteresis, and various magnetization and remanence diagrams. User contributions to the MagIC database are critical to achieving a useful research tool. We have developed a standard data and metadata template (Version 2.1) that can be used to format and upload all data at the time of publication in Earth Science journals. Software tools are provided to facilitate population of these templates within Microsoft Excel. These tools allow for the import/export of text files and provide advanced functionality to manage and edit the data, and to perform various internal checks to maintain data integrity and prepare for uploading. The MagIC Contribution Wizard at http://earthref.org/MAGIC/upload.htm executes the upload and takes only a few minutes to process several thousand data records. The standardized MagIC template files are stored in the digital archives of EarthRef.org where they

  3. The Magnetics Information Consortium (MagIC) Online Database: Uploading, Searching and Visualizing Paleomagnetic and Rock Magnetic Data

    NASA Astrophysics Data System (ADS)

    Koppers, A.; Tauxe, L.; Constable, C.; Pisarevsky, S.; Jackson, M.; Solheid, P.; Banerjee, S.; Johnson, C.; Genevey, A.; Delaney, R.; Baker, P.; Sbarbori, E.

    2005-12-01

    The Magnetics Information Consortium (MagIC) operates an online relational database including both rock and paleomagnetic data. The goal of MagIC is to store all measurements and their derived properties for studies of paleomagnetic directions (inclination, declination) and their intensities, and for rock magnetic experiments (hysteresis, remanence, susceptibility, anisotropy). MagIC is hosted under EarthRef.org at http://earthref.org/MAGIC/ and has two search nodes, one for paleomagnetism and one for rock magnetism. These nodes provide basic search capabilities based on location, reference, methods applied, material type and geological age, while allowing the user to drill down from sites all the way to the measurements. At each stage, the data can be saved and, if the available data supports it, the data can be visualized by plotting equal area plots, VGP location maps or typical Zijderveld, hysteresis, FORC, and various magnetization and remanence diagrams. All plots are made in SVG (scalable vector graphics) and thus can be saved and easily read into the user's favorite graphics programs without loss of resolution. User contributions to the MagIC database are critical to achieve a useful research tool. We have developed a standard data and metadata template (version 1.6) that can be used to format and upload all data at the time of publication in Earth Science journals. Software tools are provided to facilitate easy population of these templates within Microsoft Excel. These tools allow for the import/export of text files and they provide advanced functionality to manage/edit the data, and to perform various internal checks to high grade the data and to make them ready for uploading. The uploading is all done online by using the MagIC Contribution Wizard at http://earthref.org/MAGIC/upload.htm that takes only a few minutes to process a contribution of approximately 5,000 data records. After uploading these standardized MagIC template files will be stored in the

  4. Indirect searches of Galactic diffuse dark matter in INO-MagICAL detector

    DOE PAGES

    Khatun, Amina; Laha, Ranjan; Agarwalla, Sanjib Kumar

    2017-06-12

    Here, the signatures for the existence of dark matter are revealed only through its gravitational interaction. Theoretical arguments support that the Weakly Interacting Massive Particle (WIMP) can be a class of dark matter and it can annihilate and/or decay to Standard Model particles, among which neutrino is a favorable candidate. We show that the proposed 50 kt Magnetized Iron CALorimeter (MagICAL) detector under the India-based Neutrino Observatory (INO) project can play an important role in the indirect searches of Galactic diffuse dark matter in the neutrino and antineutrino mode separately. We present the sensitivity of 500 kt·yr MagICAL detector to set limits on the velocity-averaged self-annihilation cross-section (more » $$\\langle$$σv$$\\rangle$$) and decay lifetime (τ) of dark matter having mass in the range of 2 GeV ≤ m χ ≤ 90 GeV and 4 GeV ≤ m χ ≤ 180 GeV respectively, assuming no excess over the conventional atmospheric neutrino and antineutrino fluxes at the INO site. Our limits for low mass dark matter constrain the parameter space which has not been explored before. We show that MagICAL will be able to set competitive constraints, $$\\langle$$σv$$\\rangle$$ ≤ 1.87 × 10 -24 cm 3 s -1 for χχ→$$ν\\overline{v}$$ χχ→$$ν\\overline{v}$$ and τ ≥ 4.8 × 10 24s for χ → $$ν\\overline{v}$$ χ → $$ν\\overline{v}$$ at 90% C.L. (1 d.o.f.) for m χ = 10 GeV assuming the NFW as dark matter density profile.« less

  5. Indirect searches of Galactic diffuse dark matter in INO-MagICAL detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khatun, Amina; Laha, Ranjan; Agarwalla, Sanjib Kumar

    Here, the signatures for the existence of dark matter are revealed only through its gravitational interaction. Theoretical arguments support that the Weakly Interacting Massive Particle (WIMP) can be a class of dark matter and it can annihilate and/or decay to Standard Model particles, among which neutrino is a favorable candidate. We show that the proposed 50 kt Magnetized Iron CALorimeter (MagICAL) detector under the India-based Neutrino Observatory (INO) project can play an important role in the indirect searches of Galactic diffuse dark matter in the neutrino and antineutrino mode separately. We present the sensitivity of 500 kt·yr MagICAL detector to set limits on the velocity-averaged self-annihilation cross-section (more » $$\\langle$$σv$$\\rangle$$) and decay lifetime (τ) of dark matter having mass in the range of 2 GeV ≤ m χ ≤ 90 GeV and 4 GeV ≤ m χ ≤ 180 GeV respectively, assuming no excess over the conventional atmospheric neutrino and antineutrino fluxes at the INO site. Our limits for low mass dark matter constrain the parameter space which has not been explored before. We show that MagICAL will be able to set competitive constraints, $$\\langle$$σv$$\\rangle$$ ≤ 1.87 × 10 -24 cm 3 s -1 for χχ→$$ν\\overline{v}$$ χχ→$$ν\\overline{v}$$ and τ ≥ 4.8 × 10 24s for χ → $$ν\\overline{v}$$ χ → $$ν\\overline{v}$$ at 90% C.L. (1 d.o.f.) for m χ = 10 GeV assuming the NFW as dark matter density profile.« less

  6. 21 CFR 876.5980 - Gastrointestinal tube and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., gastrointestinal string and tubes to locate internal bleeding, double lumen tube for intestinal decompression or... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Gastrointestinal tube and accessories. 876.5980... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5980 Gastrointestinal...

  7. 21 CFR 876.5980 - Gastrointestinal tube and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., gastrointestinal string and tubes to locate internal bleeding, double lumen tube for intestinal decompression or... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gastrointestinal tube and accessories. 876.5980... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5980 Gastrointestinal...

  8. 21 CFR 876.5980 - Gastrointestinal tube and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., gastrointestinal string and tubes to locate internal bleeding, double lumen tube for intestinal decompression or... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Gastrointestinal tube and accessories. 876.5980... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5980 Gastrointestinal...

  9. 21 CFR 876.5980 - Gastrointestinal tube and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., gastrointestinal string and tubes to locate internal bleeding, double lumen tube for intestinal decompression or... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Gastrointestinal tube and accessories. 876.5980... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5980 Gastrointestinal...

  10. 21 CFR 884.4900 - Obstetric table and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Devices § 884.4900 Obstetric table and accessories. (a) Identification. An obstetric table is a device with adjustable sections designed to support a patient in the various positions required during...: patient equipment, support attachments, and cabinets for warming instruments and disposing of wastes. (b...

  11. 21 CFR 884.6190 - Assisted reproductive microscopes and microscope accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction... or embryos. Variations of microscopes and accessories used for these purposes would include phase...

  12. Beyond 31 mag arcsec-2: The Frontier of Low Surface Brightness Imaging with the Largest Optical Telescopes

    NASA Astrophysics Data System (ADS)

    Trujillo, Ignacio; Fliri, Jüergen

    2016-06-01

    The detection of structures in the sky with optical surface brightnesses fainter than 30 mag arcsec-2 (3σ in 10 × 10 arcsec boxes; r-band) has remained elusive in current photometric deep surveys. Here we show how present-day telescopes of 10 m class can provide broadband imaging 1.5-2 mag deeper than most previous results within a reasonable amount of time (I.e., <10 hr on-source integration). In particular, we illustrate the ability of the 10.4 m Gran Telescopio de Canarias telescope to produce imaging with a limiting surface brightness of 31.5 mag arcsec-2 (3σ in 10 × 10 arcsec boxes; r-band) using 8.1 hr on source. We apply this power to explore the stellar halo of the galaxy UGC 00180, a galaxy analogous to M31 located at ˜150 Mpc, by obtaining a radial profile of surface brightness down to μ r ˜ 33 mag arcsec-2. This depth is similar to that obtained using the star-counts techniques for Local Group galaxies, but is achieved at a distance where this technique is unfeasible. We find that the mass of the stellar halo of this galaxy is ˜4 × 109 M ⊙, I.e., (3 ± 1)% of the total stellar mass of the whole system. This amount of mass in the stellar halo is in agreement with current theoretical expectations for galaxies of this kind.

  13. Laser heating challenges of high yield MagLIF targets

    NASA Astrophysics Data System (ADS)

    Slutz, Stephen; Sefkow, Adam; Vesey, Roger

    2014-10-01

    The MagLIF (Magnetized Liner Inertial Fusion) concept is predicted by numerical simulation to produce fusion yields of about 100 kJ, when driven by 25 MA from the existing Z accelerator [S. A. Slutz et al. Phys. Plasmas 17, 056303 (2010)] and much higher yields with future accelerators delivering higher currents [Slutz and Vesey PRL 108, 025003 (2012)]. The fuel must be heated before compression to obtain significant fusion yields due to the relatively slow implosion velocities (~ 100 km/s) of magnetically driven liners. Lasers provide a convenient means to accomplish this pre-compressional heating of the fusion fuel, but there are challenges. The laser must penetrate a foil covering the laser entrance hole and deposit 20-30 kJ within the ~1 cm length of the liner in fuel at 6-12 mg/cc. Such high densities could result in beam scattering due to refraction and laser plasma interactions. Numerical simulations of the laser heating process are presented, which indicate that energies as high as 30 kJ could be deposited in the fuel by using two laser pulses of different wavelengths. Simulations of this process will be presented as well of results for a MagLIF design for a potential new machine delivering 50 MA of current. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under Contract DE-AC04-94AL85000.

  14. Creating a FIESTA (Framework for Integrated Earth Science and Technology Applications) with MagIC

    NASA Astrophysics Data System (ADS)

    Minnett, R.; Koppers, A. A. P.; Jarboe, N.; Tauxe, L.; Constable, C.

    2017-12-01

    The Magnetics Information Consortium (https://earthref.org/MagIC) has recently developed a containerized web application to considerably reduce the friction in contributing, exploring and combining valuable and complex datasets for the paleo-, geo- and rock magnetic scientific community. The data produced in this scientific domain are inherently hierarchical and the communities evolving approaches to this scientific workflow, from sampling to taking measurements to multiple levels of interpretations, require a large and flexible data model to adequately annotate the results and ensure reproducibility. Historically, contributing such detail in a consistent format has been prohibitively time consuming and often resulted in only publishing the highly derived interpretations. The new open-source (https://github.com/earthref/MagIC) application provides a flexible upload tool integrated with the data model to easily create a validated contribution and a powerful search interface for discovering datasets and combining them to enable transformative science. MagIC is hosted at EarthRef.org along with several interdisciplinary geoscience databases. A FIESTA (Framework for Integrated Earth Science and Technology Applications) is being created by generalizing MagIC's web application for reuse in other domains. The application relies on a single configuration document that describes the routing, data model, component settings and external services integrations. The container hosts an isomorphic Meteor JavaScript application, MongoDB database and ElasticSearch search engine. Multiple containers can be configured as microservices to serve portions of the application or rely on externally hosted MongoDB, ElasticSearch, or third-party services to efficiently scale computational demands. FIESTA is particularly well suited for many Earth Science disciplines with its flexible data model, mapping, account management, upload tool to private workspaces, reference metadata, image

  15. 21 CFR 876.4300 - Endoscopic electrosurgical unit and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Endoscopic electrosurgical unit and accessories. (a) Identification. An endoscopic electrosurgical unit and... device includes the electrosurgical generator, patient plate, electric biopsy forceps, electrode, flexible snare, electrosurgical alarm system, electrosurgical power supply unit, electrical clamp, self...

  16. [Comparison of manual and automated (MagNA Pure) nucleic acid isolation methods in molecular diagnosis of HIV infections].

    PubMed

    Alp, Alpaslan; Us, Dürdal; Hasçelik, Gülşen

    2004-01-01

    Rapid quantitative molecular methods are very important for the diagnosis of human immunodeficiency virus (HIV) infections, assessment of prognosis and follow up. The purpose of this study was to compare and evaluate the performances of conventional manual extraction method and automated MagNA Pure system, for the nucleic acid isolation step which is the first and most important step in molecular diagnosis of HIV infections. Plasma samples of 35 patients in which anti-HIV antibodies were found as positive by microparticule enzyme immunoassay and confirmed by immunoblotting method, were included in the study. The nucleic acids obtained simultaneously by manual isolation kit (Cobas Amplicor, HIV-1 Monitor Test, version 1.5, Roche Diagnostics) and automated system (MagNA Pure LC Total Nucleic Acid Isolation Kit, Roche Diagnostics), were amplified and detected in Cobas Amplicor (Roche Diagnostics) instrument. Twenty three of 35 samples (65.7%) were found to be positive, and 9 (25.7%) were negative by both of the methods. The agreement between the methods were detected as 91.4%, for qualitative results. Viral RNA copies detected by manual and MagNA Pure isolation methods were found between 76.0-7.590.000 (mean: 487.143) and 113.0-20.300.0000 (mean: 2.174.097) copies/ml, respectively. When both of the overall and individual results were evaluated, the number of RNA copies obtained with automatized system, were found higher than the manual method (p<0.05). Three samples which had low numbers of nucleic acids (113, 773, 857, respectively) with MagNA Pure, yielded negative results with manual method. In conclusion, the automatized MagNA Pure system was found to be a reliable, rapid and practical method for the isolation of HIV-RNA.

  17. Discovery of radioactive silver ((110m)Ag) in spiders and other fauna in the terrestrial environment after the meltdown of Fukushima Dai-ichi nuclear power plant.

    PubMed

    Nakanishi, Hiromi; Mori, Atsushi; Takeda, Kouki; Tanaka, Houdo; Kobayashi, Natsuko; Tanoi, Keitaro; Yamakawa, Takashi; Mori, Satoshi

    2015-01-01

    Six months after the explosion of TEPCO's Fukushima Dai-ichi nuclear power plant, radioactive silver ((110m)Ag), was detected in concentrations of 3754 Bq/kg in Nephila clavata (the orb-web spider; Joro-gumo in Japanese) collected at Nimaibashi, Iitate village in Fukushima Prefecture, whereas (110m)Ag in the soil was 43.1 Bq/kg. A survey of 35 faunal species in the terrestrial environment during the 3.5 years after the accident showed that most of Anthropoda had two orders higher (110m)Ag in their tissues than soils, although silver is not an essential element for their life. However, tracing of the activity of (110m)Ag detected in spider Atypus karschi collected regularly at a fixed location showed that it declined much faster than the physical half-life. These results suggest that (110m)Ag was at once biologically concentrated by faunal species, especially Arthropoda, through food chain. The factors affecting the subsequent rapid decline of (110m)Ag concentration in faunal species are discussed.

  18. Discovery of radioactive silver (110mAg) in spiders and other fauna in the terrestrial environment after the meltdown of Fukushima Dai-ichi nuclear power plant

    PubMed Central

    NAKANISHI, Hiromi; MORI, Atsushi; TAKEDA, Kouki; TANAKA, Houdo; KOBAYASHI, Natsuko; TANOI, Keitaro; YAMAKAWA, Takashi; MORI, Satoshi

    2015-01-01

    Six months after the explosion of TEPCO’s Fukushima Dai-ichi nuclear power plant, radioactive silver (110mAg), was detected in concentrations of 3754 Bq/kg in Nephila clavata (the orb-web spider; Joro-gumo in Japanese) collected at Nimaibashi, Iitate village in Fukushima Prefecture, whereas 110mAg in the soil was 43.1 Bq/kg. A survey of 35 faunal species in the terrestrial environment during the 3.5 years after the accident showed that most of Anthropoda had two orders higher 110mAg in their tissues than soils, although silver is not an essential element for their life. However, tracing of the activity of 110mAg detected in spider Atypus karschi collected regularly at a fixed location showed that it declined much faster than the physical half-life. These results suggest that 110mAg was at once biologically concentrated by faunal species, especially Arthropoda, through food chain. The factors affecting the subsequent rapid decline of 110mAg concentration in faunal species are discussed. PMID:25864469

  19. 21 CFR 884.4100 - Endoscopic electrocautery and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endoscopic electrocautery and accessories. 884.4100 Section 884.4100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... ammeters: continue electrode activation for 5 seconds after the visual endpoint (tissue blanching) is...

  20. 21 CFR 890.3025 - Prosthetic and orthotic accessory.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Prosthetic and orthotic accessory. 890.3025 Section 890.3025 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3025...

  1. 21 CFR 890.3025 - Prosthetic and orthotic accessory.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Prosthetic and orthotic accessory. 890.3025 Section 890.3025 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3025...

  2. 21 CFR 890.3025 - Prosthetic and orthotic accessory.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Prosthetic and orthotic accessory. 890.3025 Section 890.3025 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3025...

  3. 21 CFR 890.3025 - Prosthetic and orthotic accessory.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Prosthetic and orthotic accessory. 890.3025 Section 890.3025 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3025...

  4. 21 CFR 890.3025 - Prosthetic and orthotic accessory.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prosthetic and orthotic accessory. 890.3025 Section 890.3025 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3025...

  5. Quality detection system and method of micro-accessory based on microscopic vision

    NASA Astrophysics Data System (ADS)

    Li, Dongjie; Wang, Shiwei; Fu, Yu

    2017-10-01

    Considering that the traditional manual detection of micro-accessory has some problems, such as heavy workload, low efficiency and large artificial error, a kind of quality inspection system of micro-accessory has been designed. Micro-vision technology has been used to inspect quality, which optimizes the structure of the detection system. The stepper motor is used to drive the rotating micro-platform to transfer quarantine device and the microscopic vision system is applied to get graphic information of micro-accessory. The methods of image processing and pattern matching, the variable scale Sobel differential edge detection algorithm and the improved Zernike moments sub-pixel edge detection algorithm are combined in the system in order to achieve a more detailed and accurate edge of the defect detection. The grade at the edge of the complex signal can be achieved accurately by extracting through the proposed system, and then it can distinguish the qualified products and unqualified products with high precision recognition.

  6. MERS-CoV Accessory ORFs Play Key Role for Infection and Pathogenesis

    PubMed Central

    Menachery, Vineet D.; Mitchell, Hugh D.; Cockrell, Adam S.; Gralinski, Lisa E.; Yount, Boyd L.; Graham, Rachel L.; McAnarney, Eileen T.; Douglas, Madeline G.; Scobey, Trevor; Beall, Anne; Dinnon, Kenneth; Kocher, Jacob F.; Hale, Andrew E.; Stratton, Kelly G.; Waters, Katrina M.

    2017-01-01

    ABSTRACT While dispensable for viral replication, coronavirus (CoV) accessory open reading frame (ORF) proteins often play critical roles during infection and pathogenesis. Utilizing a previously generated mutant, we demonstrate that the absence of all four Middle East respiratory syndrome CoV (MERS-CoV) accessory ORFs (deletion of ORF3, -4a, -4b, and -5 [dORF3-5]) has major implications for viral replication and pathogenesis. Importantly, attenuation of the dORF3-5 mutant is primarily driven by dysregulated host responses, including disrupted cell processes, augmented interferon (IFN) pathway activation, and robust inflammation. In vitro replication attenuation also extends to in vivo models, allowing use of dORF3-5 as a live attenuated vaccine platform. Finally, examination of ORF5 implicates a partial role in modulation of NF-κB-mediated inflammation. Together, the results demonstrate the importance of MERS-CoV accessory ORFs for pathogenesis and highlight them as potential targets for surveillance and therapeutic treatments moving forward. PMID:28830941

  7. Cytokeratin expression in mouse lacrimal gland germ epithelium.

    PubMed

    Hirayama, Masatoshi; Liu, Ying; Kawakita, Tetsuya; Shimmura, Shigeto; Tsubota, Kazuo

    2016-05-01

    The lacrimal gland secretes tear fluids that protect the ocular surface epithelium, and its dysfunction leads to dry eye disease (DED). The functional restoration of the lacrimal gland by engraftment of a bioengineered lacrimal gland using lacrimal gland germ epithelial cells has been proposed to cure DED in mice. Here, we investigate the expression profile of cytokeratins in the lacrimal gland germ epithelium to clarify their unique characteristics. We performed quantitative polymerase chain reaction (Q-PCR) and immunohistochemistry (IHC) analysis to clarify the expression profile of cytokeratin in the lacrimal gland germ epithelium. The mRNA expression of keratin (KRT) 5, KRT8, KRT14, KRT15, and KRT18 in the lacrimal gland germ epithelium was increased compared with that in mouse embryonic stem cells and the lacrimal gland germ mesenchyme, as analyzed by Q-PCR. The expression level of KRT15 increased in the transition from stem cells to lacrimal gland germ epithelium, then decreased as the lacrimal gland matured. IHC revealed that the expression set of these cytokeratins in the lacrimal gland germ epithelium was different from that in the adult lacrimal gland. The expression of KRT15 was observed in the lacrimal gland germ epithelium, and it segmentalized into some of the basal cells in the intercanulated duct in mature gland. We determined the expression profile of cytokeratins in the lacrimal gland epithelium, and identified KRT15 as a candidate unique cellular marker for the lacrimal gland germ epithelium. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Crystal structures of 3-methyladenine DNA glycosylase MagIII and the recognition of alkylated bases

    PubMed Central

    Eichman, Brandt F.; O’Rourke, Eyleen J.; Radicella, J.Pablo; Ellenberger, Tom

    2003-01-01

    DNA glycosylases catalyze the excision of chemically modified bases from DNA. Although most glycosylases are specific to a particular base, the 3-methyladenine (m3A) DNA glycosylases include both highly specific enzymes acting on a single modified base, and enzymes with broader specificity for alkylation-damaged DNA. Our structural understanding of these different enzymatic specificities is currently limited to crystal and NMR structures of the unliganded enzymes and complexes with abasic DNA inhibitors. Presented here are high-resolution crystal structures of the m3A DNA glycosylase from Helicobacter pylori (MagIII) in the unliganded form and bound to alkylated bases 3,9-dimethyladenine and 1,N6-ethenoadenine. These are the first structures of a nucleobase bound in the active site of a m3A glycosylase belonging to the helix–hairpin–helix superfamily. MagIII achieves its specificity for positively-charged m3A not by direct interactions with purine or methyl substituent atoms, but rather by stacking the base between two aromatic side chains in a pocket that excludes 7-methylguanine. We report base excision and DNA binding activities of MagIII active site mutants, together with a structural comparison of the HhH glycosylases. PMID:14517230

  9. Incidental gastric accessory spleen during laparoscopic sleeve gastrectomy.

    PubMed

    Almazeedi, Sulaiman; Alhaddad, Eliana; Al-Khithr, Talal; Alhunaidi, Mohammed

    2017-01-01

    Bariatric surgery has shown to produce the most predictable and tangible results for weight loss, with laparoscopic sleeve gastrectomy's being the most popular one of them. However, the occurrence of previously undiagnosed diseases can be encountered during bariatric operations. The work has been reported in line with the SCARE criteria. This is the case of a 54year old morbidly obese female, presenting to our hospital for a laparoscopic sleeve gastrectomy. During her procedure, it was discovered that she has an accessory spleen on the fundus of her stomach. The decision was made to resect it with the specimen of the stomach for histopathalogical examination. Incidental findings during routine bariatric surgery are a common occurance, and therefore prompt and effective intra-op management is key to the prognosis of the patient. Accessory spleens, although uncommon, tend to be asymptomatic. However, if undiagnosed, could present with dangerous consequences. Copyright © 2017. Published by Elsevier Ltd.

  10. Meibomian gland studies: histologic and ultrastructural investigations.

    PubMed

    Jester, J V; Nicolaides, N; Smith, R E

    1981-04-01

    Heightened interest in meibomian gland dysfunction has prompted us to evaluate the normal morphological and ultrastructural characteristics of the meibomian gland. Histologic analysis of human, primate, steer, and rabbit glands revealed evidence of keratinized epithelium extending throughout the meibomian gland duct. Characteristic ultrastructural features of keratinized epithelium identified in primate and rabbit glands included tonofilaments, keratohyaline granules, lamellar bodies, and keratinized squamous cells. Comparison of the meibomian gland duct to the pilosebaceous canal and the sebaceous duct brought out certain dissimilarities such as (1) the lack of a well-developed stratum granulosum and (2) the absence of lipid inclusions within transitional cells from duct to acini. We postulate that abnormalities of the keratinizing process may be responsible for meibomian gland dysfunction states.

  11. Anatomical study of the accessory axillary vein in cadavers: a contribution to the axillary surgical approach.

    PubMed

    Felix, Valtuir Barbosa; Dos Santos, José André Bernardino; Fernandes, Katharina Jucá de Moraes; Cabral, Dhayanna Rolemberg Gama; Dos Santos, Carlos Adriano Silva; Rodrigues, Célio Fernando de Sousa; Lima, Jacqueline Silva Brito; Ramalho, Antônio José Casado

    2016-01-01

    The axillary vein is an important blood vessel that participates in drainage of the upper limb. Some individuals present a second axillary vein (accessory axillary vein), which is an important collateral drainage path. The goal of this study was to determine the incidence of the accessory axillary vein and to describe this vessel's topography. In this study, axillary dissections were carried out on twenty-four (24) human cadavers of both sexes that had been fixed with 10% formaldehyde. The upper limbs of the cadavers were still attached to the bodies and the axillary structures were preserved. Data collection was carried out and the axillary structures of the cadavers were compared. The incidence of accessory axillary veins was 58.3%, with no significant preference for sex or for side of the body. The accessory axillary vein originated from the lateral brachial vein in 39.28% of cases, from the common brachial vein in 35.71% of cases, and from the deep brachial vein in 25% of cases. Its high incidence and clinical relevance make the accessory axillary vein important for provision of collateral circulation in the event of traumatic injury to the axillary vein.

  12. Development of a Magnetic Microbead Affinity Selection Screen (MagMASS) Using Mass Spectrometry for Ligands to the Retinoid X Receptor-α

    NASA Astrophysics Data System (ADS)

    Rush, Michael D.; Walker, Elisabeth M.; Prehna, Gerd; Burton, Tristesse; van Breemen, Richard B.

    2017-03-01

    To overcome limiting factors in mass spectrometry-based screening methods such as automation while still facilitating the screening of complex mixtures such as botanical extracts, magnetic microbead affinity selection screening (MagMASS) was developed. The screening process involves immobilization of a target protein on a magnetic microbead using a variety of possible chemistries, incubation with mixtures of molecules containing possible ligands, a washing step that removes non-bound compounds while a magnetic field retains the beads in the microtiter well, and an organic solvent release step followed by LC-MS analysis. Using retinoid X receptor-α (RXRα) as an example, which is a nuclear receptor and target for anti-inflammation therapy as well as cancer treatment and prevention, a MagMASS assay was developed and compared with an existing screening assay, pulsed ultrafiltration (PUF)-MS. Optimization of MagMASS involved evaluation of multiple protein constructs and several magnetic bead immobilization chemistries. The full-length RXRα construct immobilized with amylose beads provided optimum results. Additional enhancements of MagMASS were the application of 96-well plates to enable automation, use of UHPLC instead of HPLC for faster MS analyses, and application of metabolomics software for faster, automated data analysis. Performance of MagMASS was demonstrated using mixtures of synthetic compounds and known ligands spiked into botanical extracts.

  13. Sensitivity of Salivary Glands to Radiation

    PubMed Central

    Grundmann, O.; Mitchell, G.C.; Limesand, K.H.

    2009-01-01

    Radiation therapy for head and neck cancer causes significant secondary side-effects in normal salivary glands, resulting in diminished quality of life for these individuals. Salivary glands are exquisitely sensitive to radiation and display acute and chronic responses to radiotherapy. This review will discuss clinical implications of radiosensitivity in normal salivary glands, compare animal models used to investigate radiation-induced salivary gland damage, address therapeutic advances, and project future directions in the field. PMID:19783796

  14. Making the MagIC (Magnetics Information Consortium) Web Application Accessible to New Users and Useful to Experts

    NASA Astrophysics Data System (ADS)

    Minnett, R.; Koppers, A.; Jarboe, N.; Tauxe, L.; Constable, C.; Jonestrask, L.

    2017-12-01

    Challenges are faced by both new and experienced users interested in contributing their data to community repositories, in data discovery, or engaged in potentially transformative science. The Magnetics Information Consortium (https://earthref.org/MagIC) has recently simplified its data model and developed a new containerized web application to reduce the friction in contributing, exploring, and combining valuable and complex datasets for the paleo-, geo-, and rock magnetic scientific community. The new data model more closely reflects the hierarchical workflow in paleomagnetic experiments to enable adequate annotation of scientific results and ensure reproducibility. The new open-source (https://github.com/earthref/MagIC) application includes an upload tool that is integrated with the data model to provide early data validation feedback and ease the friction of contributing and updating datasets. The search interface provides a powerful full text search of contributions indexed by ElasticSearch and a wide array of filters, including specific geographic and geological timescale filtering, to support both novice users exploring the database and experts interested in compiling new datasets with specific criteria across thousands of studies and millions of measurements. The datasets are not large, but they are complex, with many results from evolving experimental and analytical approaches. These data are also extremely valuable due to the cost in collecting or creating physical samples and the, often, destructive nature of the experiments. MagIC is heavily invested in encouraging young scientists as well as established labs to cultivate workflows that facilitate contributing their data in a consistent format. This eLightning presentation includes a live demonstration of the MagIC web application, developed as a configurable container hosting an isomorphic Meteor JavaScript application, MongoDB database, and ElasticSearch search engine. Visitors can explore the Mag

  15. Granular cutaneous glands in the frog Physalaemus biligonigerus (Anura, Leptodactylidae): comparison between ordinary serous and 'inguinal' glands.

    PubMed

    Delfino, G; Brizzi, R; Alvarez, B B; Gentili, M

    1999-12-01

    Beside the ordinary granular (or serous) glands, the skin of the leptodactylid frog Physalaemus biligonigerus possesses peculiar clusters of large granular units, the 'inguinal' glands, located in the dorsolateral areas of the pelvic girdle. Both gland types store their specific products within the syncytial cytoplasm of the secretory unit. These secretory materials consist of spheroidal or ellipsoidal bodies (granules) with a repeating substructure. The subcellular features of the immature products of the ordinary serous and inguinal glands are identical. However, these products undergo divergent maturative processes, leading to fluidation on the one hand and condensation on the other. Secretory release into the small gland lumen was observed in both cases, involving merocrine mechanisms. On the basis of the analysis of cutaneous serous gland polymorphism in anurans, the inguinal units in P. biligonigerus do not appear to be an independent line. Rather, these large units belong to the ordinary serous type and represent a gland population specialized in the storage of remarkable amounts of product used in chemical defence of the skin.

  16. 21 CFR 884.4150 - Bipolar endoscopic coagulator-cutter and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... high frequency electrical current through tissue between two electrical contacts of a probe. This generic type of device may include the following accessories: an electrical generator, probes, and...

  17. 21 CFR 884.4150 - Bipolar endoscopic coagulator-cutter and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... high frequency electrical current through tissue between two electrical contacts of a probe. This generic type of device may include the following accessories: an electrical generator, probes, and...

  18. 21 CFR 884.4150 - Bipolar endoscopic coagulator-cutter and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... high frequency electrical current through tissue between two electrical contacts of a probe. This generic type of device may include the following accessories: an electrical generator, probes, and...

  19. 21 CFR 884.4150 - Bipolar endoscopic coagulator-cutter and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... high frequency electrical current through tissue between two electrical contacts of a probe. This generic type of device may include the following accessories: an electrical generator, probes, and...

  20. 21 CFR 884.4900 - Obstetric table and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Obstetric table and accessories. 884.4900 Section 884.4900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...: patient equipment, support attachments, and cabinets for warming instruments and disposing of wastes. (b...

  1. 21 CFR 878.4160 - Surgical camera and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Surgical camera and accessories. 878.4160 Section 878.4160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4160 Surgical camera...

  2. 21 CFR 878.4350 - Cryosurgical unit and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cryosurgical unit and accessories. 878.4350 Section 878.4350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4350 Cryosurgical unit...

  3. 21 CFR 878.4160 - Surgical camera and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Surgical camera and accessories. 878.4160 Section 878.4160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4160 Surgical camera...

  4. 21 CFR 878.4160 - Surgical camera and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Surgical camera and accessories. 878.4160 Section 878.4160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4160 Surgical camera...

  5. 21 CFR 878.4350 - Cryosurgical unit and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cryosurgical unit and accessories. 878.4350 Section 878.4350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4350 Cryosurgical unit...

  6. 21 CFR 878.4350 - Cryosurgical unit and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cryosurgical unit and accessories. 878.4350 Section 878.4350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4350 Cryosurgical unit...

  7. 21 CFR 878.4160 - Surgical camera and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgical camera and accessories. 878.4160 Section 878.4160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4160 Surgical camera...

  8. 21 CFR 878.4160 - Surgical camera and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Surgical camera and accessories. 878.4160 Section 878.4160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4160 Surgical camera...

  9. 21 CFR 878.4350 - Cryosurgical unit and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cryosurgical unit and accessories. 878.4350 Section 878.4350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4350 Cryosurgical unit...

  10. The harderian gland: a tercentennial review.

    PubMed Central

    Payne, A P

    1994-01-01

    The harderian gland was first described in 1694 by Johann Jacob Harder (1656-1711). It occurs in most terrestrial vertebrates and is located within the orbit where, in some species, it is the largest structure. It may be compound tubular or compound tubuloalveolar, and its secretory duct is usually morphologically distinct only after leaving the substance of the gland to open on the surface of the nictitating membrane. The tubules of the gland are formed of a single layer of columnar epithelial cells surrounded by myoepithelial cells. The chief product(s) of the gland varies between different groups of vertebrates, and epithelial cells possess granules or vacuoles whose contents may be mucous, serous or lipid. In rodents, the gland synthesises lipids, porphyrins and indoles. In the case of lipid vacuoles, the gland is unusual in releasing these by an exocytotic mechanism. It is unclear whether the gland can act both as an exocrine and endocrine organ. There is control of gland structure and synthesis through a variety of humoral agents, including gonadal, thyroid and pituitary hormones; in addition there is a rich autonomic innervation and many neuropeptides have been identified. The proposed functions of the gland are remarkably diverse and include the gland being (1) a source of 'saliva', (2) a site of immune response, (3) a photoprotective organ, (4) part of a retinal-pineal axis, (5) a source of pheromones, (6) a source of thermoregulatory lipids, (7) a site of osmoregulation, and (8) a source of growth factors. The gland is discussed in terms of its embryology and phylogeny, and in relation to ecological variables. Several goals of future research are identified. Images Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 11 Fig. 12 Fig. 13 Fig. 14 Fig. 15 Fig. 16 Fig. 16 Fig. 17 Fig. 18 Fig. 19 Fig. 20 Fig. 21 Fig. 22 Fig. 23 Fig. 24 Fig. 25 Fig. 26 Fig. 27 Fig. 28 Fig. 29 Fig. 30 Fig. 31 Fig. 32 Fig. 36 Fig. 37 Fig. 38 Fig. 40 PMID:7559104

  11. 3D Stagnation instabilities in MagLIF loads on the Z Generator

    NASA Astrophysics Data System (ADS)

    Jennings, Christopher

    2017-10-01

    Experiments with Magnetized Liner Inertial Fusion (MagLIF) loads have successfully demonstrated the premise of magnetized fusion. While these experiments are increasingly well diagnosed, many of the measurements (particularly during stagnation) are time integrated, limited in spatial resolution or require additional assumptions to interpret in the context of a structured, rapidly evolving system. As such, there is some ambiguity over what may be limiting performance. Poor laser coupling in preheating the fuel prior to implosion has been suggested as a mechanism. Mix of high Z contaminants that cool the fuel is also a significant concern. In addition, time integrated crystal imaging has shown significant structure in the final fuel assembly indicating potential disruption from instabilities. Understanding the balance between these degradation mechanisms is vital to progress with MagLif. We compare several sets of experimental data with synthetically generated data from systematically varied 3D resistive-MHD simulations to gain insight into the relative contributions of different degradation mechanisms. We demonstrate how some measurements strongly indicate disruption from liner material penetrating into the fuel at stagnation, and discuss the implications this has for how MagLif targets work and scale to larger drive currents. We then explore the extent to which different combinations of instability development, current delivery, high-Z mix into the fuel and initial laser deposition can be differentiated in our existing measurements. Better determining the dominant degradation mechanisms can directly influence the direction we take to improve performance, or our confidence in scaling these targets to higher currents. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology and Engineering Solutions of Sandia LLC, a wholly owned subsidiary of Honeywell International Inc. for the U.S. DoE's NNSA under contract DE-NA0003525.

  12. Correction of accessory axillary breast tissue without visible scar.

    PubMed

    Kim, Young Soo

    2004-01-01

    Various methods for correction of accessory axillary breast tissue have been proposed, including simple excision, diamond-shaped excision, a Y-V technique, and lipoplasty. We present an effective method for correction of a prominent axillary mound that combines lipoplasty with excision of accessory breast tissue along the axillary transverse line. Preoperative markings included an incision within the natural wrinkle line in the axillary fold, and demarcation of areas in which lipoplasty and excision were to be performed. After lipoplasty, deep dissection was performed to isolate and remove accessory breast tissue and excess fat tissue. A compression dressing was applied for 1 to 2 weeks postoperatively, and the patient was instructed to wear a sports bra for 1 to 2 months after removal of the dressing. We treated 7 patients using this procedure between October 1999 and March 2003. No major postoperative complications were detected and recurrence was not noted during the follow-up periods. Aesthetic results were satisfactory. We believe that a procedure that combines lipoplasty and excision provides numerous advantages as a surgical option in treating a prominent axillary mound. The main advantage is that the final scar is laid in the natural axillary fold, rendering scars less conspicuous and eliminating the need to remove excess skin. The one disadvantage was that elevation of the skin flap via small, remote incisions initially produced surgical difficulties, but these were overcome with experience.

  13. 21 CFR 876.5090 - Suprapubic urological catheter and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... accessories is a flexible tubular device that is inserted through the abdominal wall into the urinary bladder with the aid of a trocar and cannula. The device is used to pass fluids to and from the urinary tract...

  14. INTERIOR VIEW OF BATHROOM 2. SHOWING ORIGINAL TILE. CERAMIC ACCESSORIES, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    INTERIOR VIEW OF BATHROOM 2. SHOWING ORIGINAL TILE. CERAMIC ACCESSORIES, AND MARBLE THRESHOLD. VIEW FACING EAST. - Hickam Field, Officers' Housing Type G, 205 Seventh Street, Honolulu, Honolulu County, HI

  15. Persistent Increase in Blood Pressure After Renal Nerve Stimulation in Accessory Renal Arteries After Sympathetic Renal Denervation.

    PubMed

    de Jong, Mark R; Hoogerwaard, Annemiek F; Gal, Pim; Adiyaman, Ahmet; Smit, Jaap Jan J; Delnoy, Peter Paul H M; Ramdat Misier, Anand R; van Hasselt, Boudewijn A A M; Heeg, Jan-Evert; le Polain de Waroux, Jean-Benoit; Lau, Elizabeth O Y; Staessen, Jan A; Persu, Alexandre; Elvan, Arif

    2016-06-01

    Blood pressure response to renal denervation is highly variable, and the proportion of responders is disappointing. This may be partly because of accessory renal arteries too small for denervation, causing incomplete ablation. Renal nerve stimulation before and after renal denervation is a promising approach to assess completeness of renal denervation and may predict blood pressure response to renal denervation. The objective of the current study was to assess renal nerve stimulation-induced blood pressure increase before and after renal sympathetic denervation in main and accessory renal arteries of anaesthetized patients with drug-resistant hypertension. The study included 21 patients. Nine patients had at least 1 accessory renal artery in which renal denervation was not feasible. Renal nerve stimulation was performed in the main arteries of all patients and in accessory renal arteries of 6 of 9 patients with accessory arteries, both before and after renal sympathetic denervation. Renal nerve stimulation before renal denervation elicited a substantial increase in systolic blood pressure, both in main (25.6±2.9 mm Hg; P<0.001) and accessory (24.3±7.4 mm Hg; P=0.047) renal arteries. After renal denervation, renal nerve stimulation-induced systolic blood pressure increase was blunted in the main renal arteries (Δ systolic blood pressure, 8.6±3.7 mm Hg; P=0.020), but not in the nondenervated renal accessory renal arteries (Δ systolic blood pressure, 27.1±7.6 mm Hg; P=0.917). This residual source of renal sympathetic tone may result in persistent hypertension after ablation and partly account for the large response variability. © 2016 American Heart Association, Inc.

  16. 14 CFR 121.251 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Engine accessory section diaphragm. 121.251... REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.251 Engine... complies with § 121.247 must be provided on air-cooled engines to isolate the engine power section and all...

  17. 14 CFR 121.251 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Engine accessory section diaphragm. 121.251... REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.251 Engine... complies with § 121.247 must be provided on air-cooled engines to isolate the engine power section and all...

  18. 14 CFR 121.251 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Engine accessory section diaphragm. 121.251... REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.251 Engine... complies with § 121.247 must be provided on air-cooled engines to isolate the engine power section and all...

  19. 14 CFR 121.251 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Engine accessory section diaphragm. 121.251... REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.251 Engine... complies with § 121.247 must be provided on air-cooled engines to isolate the engine power section and all...

  20. Biotin avidin amplified magnetic immunoassay for hepatitis B surface antigen detection using GoldMag nanoparticles

    NASA Astrophysics Data System (ADS)

    Yu, An; Geng, Tingting; Fu, Qiang; Chen, Chao; Cui, Yali

    2007-04-01

    Using GoldMag (Fe3O4/Au) nanoparticles as a carrier, a biotin-avidin amplified ELISA was developed to detect hepatitis B surface antigen (HBsAg). A specific antibody was labeled with biotin and then used to detect the antigen with an antibody coated on GoldMag nanoparticles by a sandwich ELISA assay. The results showed that 5 mol of biotin were surface bound per mole of antibody. The biotin-avidin amplified ELISA assay has a higher sensitivity than that of the direct ELISA assay. There is 5-fold difference between HBsAg positive and negative serum even at dilution of 1:10000, and the relative standard deviation of the parallel positive serum at dilution of 1:4000 is 5.98% (n=11).

  1. Dufour's gland and poison gland chemistry of the myrmicine ant,Messor capensis (Mayr).

    PubMed

    Brand, J M; Mpuru, S P

    1993-07-01

    The Cape harvester ant,Messor capensis (Mayr), is widespread in the more arid regions of southern Africa, where it forms trails many meters long and harvests considerable quantities of seeds. The poison gland contains primarily the alkaloid, anabaseine, with minor amounts of the related alkaloid, anabasine, and an unidentified compound. The Dufour's gland contains predominantly alkanes and alkenes of carbon chain length 12-23.n-Pentadecane is the major component, with lesser amounts ofn-pentadecene,n-tridecane,n-heptadecane,n-tetradecane,n-heneicosene, andn-tricosene. The dienes,n-heneicosadiene andn-tricosadiene are rather unusual components of the Dufour's gland of ants.

  2. [Clinicopathological analyses of accessory breast cancer: a report of 22 cases].

    PubMed

    Wang, Haotian; Duan, Jingjing; Xin, Fei; Cao, Xuchen

    2015-01-27

    To explore the clinicopathological characteristics, diagnosis, multi-disciplinary therapy and prognosis of accessory breast cancer. The clinical data were retrospectively analyzed for 22 patients with accessory breast cancer from December 2000 and September 2013. Three patients underwent breast-conserving local wide excision of tumor plus axillary lymph node dissection while the remainder had Auchincloss or Halsted mastectomy. The most common histological type was infiltrating ductal carcinoma (n = 16, 72%) and one of them was associated with mucous adenocarcinoma. There were carcinoma simplex (n = 1), papillary adenocarcinoma (n = 1) and adenocarcinoma (n = 4). The most common pathological stages (according to AJCC Staging of Breast Cancer, 2002, 6th edition) were II (n = 15, 68%),I(n = 3), III (n = 4) and IV (n = 0). The median follow-up period was 3 (1-14) years. And the follow-up rate was 100%.Until October 2014, 2 patients died from metastasis and the remainder survived. Accessory breast cancer is rare and has a worse prognosis.Now the clinical diagnostic criteria to it remains controversial and the diagnosis is often late. A definite diagnosis is made on the basis of clinical characteristics, postoperative pathology and imaging examinations. And surgery remains a major option.

  3. Laparoendoscopic single site (LESS) in vivo suturing using a magnetic anchoring and guidance system (MAGS) camera in a porcine model: impact on ergonomics and workload.

    PubMed

    Yin, Gang; Han, Woong Kyu; Faddegon, Stephen; Tan, Yung Khan; Liu, Zhuo-Wei; Olweny, Ephrem O; Scott, Daniel J; Cadeddu, Jeffrey A

    2013-01-01

    To compare the ergonomics and workload of the surgeon during single-site suturing while using the magnetic anchoring and guidance system (MAGS) camera vs a conventional laparoscope. Seven urologic surgeons were enrolled and divided into an expert group (n=2) and a novice group (n=5) according to their laparoendoscopic single-site (LESS) experience. Each surgeon performed 2 conventional LESS and 2 MAGS camera-assisted LESS vesicostomy closures in a porcine model. A Likert scale (scoring 1-5) questionnaire assessing workload, ergonomics, technical difficulty, visualization, and needle handling, as well as a validated National Aeronautics and Space Administration Task Load Index (NASA-TLX) questionnaire were used to evaluate the tasks and workloads. MAGS LESS suturing was universally favored by expert and novice surgeons compared with conventional LESS in workload (3.4 vs 4.2), ergonomics (3.4 vs 4.4), technical challenge (3.3 vs 4.3), visualization (2.4 vs 3.3), and needle handling (3.1 vs 3.9 respectively; P<.05 for all categories). Surgeon NASA-TLX assessments found MAGS LESS suturing significantly decreased the workload in physical demand (P=.004), temporal demand (P=.017), and effort (P=.006). External instrument clashing was significantly reduced in MAGS LESS suturing (P<.001). The total operative time of MAGS LESS suturing was comparable to that of conventional LESS (P=.89). MAGS camera technology significantly decreased surgeon workload and improved ergonomics. Nevertheless, LESS suturing and knot tying remains a challenging task that requires training, regardless of which camera is used. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. 75 FR 41523 - Paris Accessories, Inc., Including On-Site Leased Workers From Job Connections, New Smithville...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-16

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-71,106; TA-W-71,106A] Paris Accessories, Inc., Including On-Site Leased Workers From Job Connections, New Smithville, PA; Paris... Paris Accessories, Inc., including on-site leased workers from Job Connections, New Smithville...

  5. 76 FR 585 - In the Matter of Certain Handbags, Luggage, Accessories and Packaging Thereof; Notice of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-05

    ..., Accessories and Packaging Thereof; Notice of Investigation AGENCY: U.S. International Trade Commission. ACTION... packaging thereof by reason of infringement of U.S. Trademark Registration No. 297,594 (``the `594 trademark... certain handbags, luggage, accessories and packaging thereof that infringe the `594 trademark; the `625...

  6. Interplanetary Dust Observations by the Juno MAG Investigation

    NASA Astrophysics Data System (ADS)

    Jørgensen, John; Benn, Mathias; Denver, Troelz; Connerney, Jack; Jørgensen, Peter; Bolton, Scott; Brauer, Peter; Levin, Steven; Oliversen, Ronald

    2017-04-01

    The spin-stabilized and solar powered Juno spacecraft recently concluded a 5-year voyage through the solar system en route to Jupiter, arriving on July 4th, 2016. During the cruise phase from Earth to the Jovian system, the Magnetometer investigation (MAG) operated two magnetic field sensors and four co-located imaging systems designed to provide accurate attitude knowledge for the MAG sensors. One of these four imaging sensors - camera "D" of the Advanced Stellar Compass (ASC) - was operated in a mode designed to detect all luminous objects in its field of view, recording and characterizing those not found in the on-board star catalog. The capability to detect and track such objects ("non-stellar objects", or NSOs) provides a unique opportunity to sense and characterize interplanetary dust particles. The camera's detection threshold was set to MV9 to minimize false detections and discourage tracking of known objects. On-board filtering algorithms selected only those objects tracked through more than 5 consecutive images and moving with an apparent angular rate between 15"/s and 10,000"/s. The coordinates (RA, DEC), intensity, and apparent velocity of such objects were stored for eventual downlink. Direct detection of proximate dust particles is precluded by their large (10-30 km/s) relative velocity and extreme angular rates, but their presence may be inferred using the collecting area of Juno's large ( 55m2) solar arrays. Dust particles impact the spacecraft at high velocity, creating an expanding plasma cloud and ejecta with modest (few m/s) velocities. These excavated particles are revealed in reflected sunlight and tracked moving away from the spacecraft from the point of impact. Application of this novel detection method during Juno's traversal of the solar system provides new information on the distribution of interplanetary (µm-sized) dust.

  7. Anatomy and histology of rodent and human major salivary glands: -overview of the Japan salivary gland society-sponsored workshop-.

    PubMed

    Amano, Osamu; Mizobe, Kenichi; Bando, Yasuhiko; Sakiyama, Koji

    2012-10-31

    MAJOR SALIVARY GLANDS OF BOTH HUMANS AND RODENTS CONSIST OF THREE PAIRS OF MACROSCOPIC GLANDS: parotid, submandibular, and sublingual. These glands secrete serous, mucous or mixed saliva via the proper main excretory ducts connecting the glandular bodies with the oral cavity. A series of discoveries about the salivary ducts in the 17th century by Niels Stensen (1638-1686), Thomas Wharton (1614-1673), and Caspar Bartholin (1655-1738) established the concept of exocrine secretion as well as salivary glands. Recent investigations have revealed the endocrine functions of parotin and a variety of cell growth factors produced by salivary glands.The present review aims to describe macroscopic findings on the major salivary glands of rodents and the microscopic differences between those of humans and rodents, which review should be of interest to those researchers studying salivary glands.

  8. Anatomical study of the accessory axillary vein in cadavers: a contribution to the axillary surgical approach

    PubMed Central

    Felix, Valtuir Barbosa; dos Santos, José André Bernardino; Fernandes, Katharina Jucá de Moraes; Cabral, Dhayanna Rolemberg Gama; dos Santos, Carlos Adriano Silva; Rodrigues, Célio Fernando de Sousa; Lima, Jacqueline Silva Brito; Ramalho, Antônio José Casado

    2016-01-01

    Abstract Background The axillary vein is an important blood vessel that participates in drainage of the upper limb. Some individuals present a second axillary vein (accessory axillary vein), which is an important collateral drainage path. Objectives The goal of this study was to determine the incidence of the accessory axillary vein and to describe this vessel’s topography. Methods In this study, axillary dissections were carried out on twenty-four (24) human cadavers of both sexes that had been fixed with 10% formaldehyde. The upper limbs of the cadavers were still attached to the bodies and the axillary structures were preserved. Data collection was carried out and the axillary structures of the cadavers were compared. Results The incidence of accessory axillary veins was 58.3%, with no significant preference for sex or for side of the body. The accessory axillary vein originated from the lateral brachial vein in 39.28% of cases, from the common brachial vein in 35.71% of cases, and from the deep brachial vein in 25% of cases. Conclusions Its high incidence and clinical relevance make the accessory axillary vein important for provision of collateral circulation in the event of traumatic injury to the axillary vein.

  9. EFFECT OF INFLAMMATION ON LACRIMAL GLAND FUNCTION

    PubMed Central

    Zoukhri, Driss

    2005-01-01

    The lacrimal gland is the main contributor to the aqueous layer of the tear film. It secretes proteins, electrolytes and water, which helps to nourish and protect the ocular surface. Lacrimal gland secretion is primarily under neural control, which is achieved through a neural reflex arc. Stimuli to the ocular surface activate afferent sensory nerves in the cornea and conjunctiva. This in turn activates efferent parasympathetic and sympathetic nerves in the lacrimal gland to stimulate secretion. Sex steroid hormones are also important regulators of lacrimal gland functions. A decrease or lack of lacrimal gland secretion is the leading cause of aqueous tear deficient dry eye syndrome (DES). It has been suggested that DES is an inflammatory disorder that affects the ocular surface and the lacrimal gland. In several pathological instances, the lacrimal gland can become a target of the immune system and show signs of inflammation. This can result from autoimmune diseases (Sjögren's syndrome), organ transplantation (graft versus host disease), or simply as a result of aging. The hallmarks of lacrimal gland inflammation are the presence of focal lymphocytic infiltrates and increased production of proinflammatory cytokines. The mechanisms leading to lacrimal gland dysfunction are still poorly understood. Apoptosis, production of autoantibodies, hormonal imbalance, alterations in signaling molecules, neural dysfunction, and increased levels of proinflammatory cytokines have been proposed as possible mediators of lacrimal gland insufficiency in disease states. PMID:16309672

  10. Preparation of 99Tcm-MAG3: no confirmation that sodium chloride injections from plastic containers affect radiochemical purity.

    PubMed

    Millar, A M; O'Brien, L M

    1998-05-01

    Reports have suggested that when sodium chloride injections from a plastic ampoule are used during the preparation of 99Tcm-mercaptoacetyltriglycine (99Tcm-MAG3), the radiochemical purity of the final product might be reduced. A study was therefore undertaken to examine the effect of sodium chloride injections from five manufacturers on the radiochemical purity and stability of 99Tcm-MAG3. One sodium chloride injection was supplied in a glass vial, three in plastic ampoules and one in a plastic infusion bag. Three batches of sodium chloride injections from each manufacturer were tested. The radiopharmaceutical was prepared at a radioactive concentration of 1.1 GBq in 10 ml according to the instructions of the manufacturer of TechneScan MAG3. Analysis of radiochemical purity was performed by high-performance liquid chromatography immediately after preparation and 6 h later. Using 95% as the minimum acceptable radiochemical purity, all the products were satisfactory over the 6 h test period. No manufacturer's sodium chloride injection was found to have a statistically significant effect on the radiochemical purity. Based on the 15 batches of sodium chloride injection tested, this study cannot confirm that sodium chloride injections from a plastic container affect the radiochemical purity of 99Tcm-MAG3. However, in view of the known sensitivity of some 99Tcm radiopharmaceuticals to external influences, it is probably good practice to test radiochemical purity when new batches of ancillary materials, such as sodium chloride injections, are introduced.

  11. CrowdMag - Crowdsourcing magnetic data

    NASA Astrophysics Data System (ADS)

    Nair, M. C.; Boneh, N.; Chulliat, A.

    2014-12-01

    In the CrowdMag project, we explore whether digital magnetometers built in modern mobile phones can be used as scientific instruments to measure Earth's magnetic field. Most modern mobile phones have digital magnetometers to orient themselves. A phone's magnetometer measures three components of the local magnetic field with a typical sensitivity of about 150 to 600 nanotesla (nT). By combining data from vector magnetometers and accelerometers, phone's orientation is determined. Using phone's Internet connection, magnetic data and location are sent to a central server. At the server, we check quality of the magnetic data from all users and make the data available to the public as aggregate maps. We have two long-term goals. 1) Develop near-real-time models of Earth's time changing magnetic field by reducing man-made noise from crowdsourced data and combining it with geomagnetic data from other sources. 2) Improving accuracy of magnetic navigation by mapping magnetic noise sources (for e.g. power transformer and iron pipes). Key challenges to this endeavor are the low sensitivity of the phone's magnetometer and the noisy environment within and surrounding the phone. URL : http://www.ngdc.noaa.gov/geomag/crowdmag.shtml

  12. Behavioral Abnormalities in a Mouse Model of Chronic Toxoplasmosis Are Associated with MAG1 Antibody Levels and Cyst Burden.

    PubMed

    Xiao, Jianchun; Li, Ye; Prandovszky, Emese; Kannan, Geetha; Viscidi, Raphael P; Pletnikov, Mikhail V; Yolken, Robert H

    2016-04-01

    There is marked variation in the human response to Toxoplasma gondii infection. Epidemiological studies indicate associations between strain virulence and severity of toxoplasmosis. Animal studies on the pathogenic effect of chronic infection focused on relatively avirulent strains (e.g. type II) because they can easily establish latent infections in mice, defined by the presence of bradyzoite-containing cysts. To provide insight into virulent strain-related severity of human toxoplasmosis, we established a chronic model of the virulent type I strain using outbred mice. We found that type I-exposed mice displayed variable outcomes ranging from aborted to severe infections. According to antibody profiles, we found that most of mice generated antibodies against T. gondii organism but varied greatly in the production of antibodies against matrix antigen MAG1. There was a strong correlation between MAG1 antibody level and brain cyst burden in chronically infected mice (r = 0.82, p = 0.0021). We found that mice with high MAG1 antibody level displayed lower weight, behavioral changes, altered levels of gene expression and immune activation. The most striking change in behavior we discovered was a blunted response to amphetamine-trigged locomotor activity. The extent of most changes was directly correlated with levels of MAG1 antibody. These changes were not found in mice with less cyst burden or mice that were acutely but not chronically infected. Our finding highlights the critical role of cyst burden in a range of disease severity during chronic infection, the predictive value of MAG1 antibody level to brain cyst burden and to changes in behavior or other pathology in chronically infected mice. Our finding may have important implications for understanding the heterogeneous effects of T. gondii infections in human.

  13. Behavioral Abnormalities in a Mouse Model of Chronic Toxoplasmosis Are Associated with MAG1 Antibody Levels and Cyst Burden

    PubMed Central

    Xiao, Jianchun; Li, Ye; Prandovszky, Emese; Kannan, Geetha; Viscidi, Raphael P.; Pletnikov, Mikhail V.; Yolken, Robert H.

    2016-01-01

    There is marked variation in the human response to Toxoplasma gondii infection. Epidemiological studies indicate associations between strain virulence and severity of toxoplasmosis. Animal studies on the pathogenic effect of chronic infection focused on relatively avirulent strains (e.g. type II) because they can easily establish latent infections in mice, defined by the presence of bradyzoite-containing cysts. To provide insight into virulent strain-related severity of human toxoplasmosis, we established a chronic model of the virulent type I strain using outbred mice. We found that type I-exposed mice displayed variable outcomes ranging from aborted to severe infections. According to antibody profiles, we found that most of mice generated antibodies against T. gondii organism but varied greatly in the production of antibodies against matrix antigen MAG1. There was a strong correlation between MAG1 antibody level and brain cyst burden in chronically infected mice (r = 0.82, p = 0.0021). We found that mice with high MAG1 antibody level displayed lower weight, behavioral changes, altered levels of gene expression and immune activation. The most striking change in behavior we discovered was a blunted response to amphetamine-trigged locomotor activity. The extent of most changes was directly correlated with levels of MAG1 antibody. These changes were not found in mice with less cyst burden or mice that were acutely but not chronically infected. Our finding highlights the critical role of cyst burden in a range of disease severity during chronic infection, the predictive value of MAG1 antibody level to brain cyst burden and to changes in behavior or other pathology in chronically infected mice. Our finding may have important implications for understanding the heterogeneous effects of T. gondii infections in human. PMID:27124472

  14. Clothing/Apparel and Accessories Merchandising. A Suggested Interdisciplinary Guide.

    ERIC Educational Resources Information Center

    Wray, Ralph D.; Hayden, Margaret B.

    This curriculum guide contains three sections: introduction, curriculum material, and an annotated bibliography. Introductory information provides an overview of the clothing/apparel and accessories merchandising area, aptitudes needed, and career opportunities; discusses potential career ladders, which are divided into entry level, middle…

  15. Gland segmentation in prostate histopathological images

    PubMed Central

    Singh, Malay; Kalaw, Emarene Mationg; Giron, Danilo Medina; Chong, Kian-Tai; Tan, Chew Lim; Lee, Hwee Kuan

    2017-01-01

    Abstract. Glandular structural features are important for the tumor pathologist in the assessment of cancer malignancy of prostate tissue slides. The varying shapes and sizes of glands combined with the tedious manual observation task can result in inaccurate assessment. There are also discrepancies and low-level agreement among pathologists, especially in cases of Gleason pattern 3 and pattern 4 prostate adenocarcinoma. An automated gland segmentation system can highlight various glandular shapes and structures for further analysis by the pathologist. These objective highlighted patterns can help reduce the assessment variability. We propose an automated gland segmentation system. Forty-three hematoxylin and eosin-stained images were acquired from prostate cancer tissue slides and were manually annotated for gland, lumen, periacinar retraction clefting, and stroma regions. Our automated gland segmentation system was trained using these manual annotations. It identifies these regions using a combination of pixel and object-level classifiers by incorporating local and spatial information for consolidating pixel-level classification results into object-level segmentation. Experimental results show that our method outperforms various texture and gland structure-based gland segmentation algorithms in the literature. Our method has good performance and can be a promising tool to help decrease interobserver variability among pathologists. PMID:28653016

  16. Male-induced costs of mating for females compensated by offspring viability benefits in an insect.

    PubMed

    Garcia-Gonzalez, F; Simmons, L W

    2010-10-01

    Sexual conflict facilitates the evolution of traits that increase the reproductive success of males at the expense of components of female fitness. Theory suggests that indirect benefits are unlikely to offset the direct costs to females from antagonistic male adaptations, but empirical studies examining the net fitness pay-offs of the interaction between the sexes are scarce. Here, we investigate whether matings with males that invest intrinsically more into accessory gland tissue undermine female lifetime reproductive success (LRS) in the cricket Teleogryllus oceanicus. We found that females incur a longevity cost of mating that is proportional to the partner's absolute investment into the production of accessory gland products. However, male accessory gland weight positively influences embryo survival, and harmful ejaculate-induced effects are cancelled out when these are put in the context of female LRS. The direct costs of mating with males that sire offspring with higher viability are thus compensated by direct and possibly indirect genetic benefits in this species. © 2010 The Authors. Journal Compilation © 2010 European Society For Evolutionary Biology.

  17. Human lacrimal gland mucins.

    PubMed

    Paulsen, Friedrich; Langer, Gesa; Hoffmann, Werner; Berry, Monica

    2004-05-01

    The objective of this study was to determine whether the lacrimal gland synthesizes mucins and whether they are changed with age or in cases of dry eye. Expression of mucins in human lacrimal glands was monitored by reverse transcription-polymerase chain reaction analysis. Furthermore, the presence and distribution of MUC1, -2, -4, -5AC, -5B, -6 and -7 in epithelia of the human lacrimal gland and its excretory duct system were assessed with antisera to mucin peptide cores. Thirty normal tissues from cadavers of different ages were tested, plus four with dry eye treated with artificial tears. Expression studies detected mRNAs for mucins MUC1, -4, -5AC, -5B, -6 and -7; whereas the MUC2 message was absent. The message for MUC4 was present in all four cases of dry eye, but only in six out of the 30 normal glands from individuals who did not receive artificial tears. MUC6 mRNA was detected only in about half of the investigated samples. Immunohistochemistry revealed membrane-bound MUC1 at the apical surface of acinar cells, absence of MUC2, MUC5AC associated with goblet cells of excretory ducts, MUC5B and -7 in the cytoplasm of acinar cells, and MUC7 also in epithelial cells of excretory ducts. MUC4 mucin was detected only in those individuals in which message was identified. In dry eyes, MUC5AC and -5B were localized in the same acinar cells; whereas MUC2 and MUC6 were not detectable. Dot-blot analysis clearly revealed increased amounts of MUC4, -5AC, and -5B in the glands of elderly women who received treatment for dry eyes. These results confirm that the human lacrimal gland synthesizes a spectrum of mucins; part of them might be correlated with age. Copyright 2004 Springer-Verlag

  18. 26 CFR 48.4062(a)-1 - Specific parts or accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., and Taxable Fuel Automotive and Related Items § 48.4062(a)-1 Specific parts or accessories. Spark plugs, storage batteries, leaf springs, coils, timers, and tire chains, which are suitable for use on or...

  19. Accessory enzymes influence cellulase hydrolysis of the model substrate and the realistic lignocellulosic biomass.

    PubMed

    Sun, Fubao Fuebiol; Hong, Jiapeng; Hu, Jinguang; Saddler, Jack N; Fang, Xu; Zhang, Zhenyu; Shen, Song

    2015-11-01

    The potential of cellulase enzymes in the developing and ongoing "biorefinery" industry has provided a great motivation to develop an efficient cellulase mixture. Recent work has shown how important the role that the so-called accessory enzymes can play in an effective enzymatic hydrolysis. In this study, three newest Novozymes Cellic CTec cellulase preparations (CTec 1/2/3) were compared to hydrolyze steam pretreated lignocellulosic substrates and model substances at an identical FPA loading. These cellulase preparations were found to display significantly different hydrolytic performances irrelevant with the FPA. And this difference was even observed on the filter paper itself when the FPA based assay was revisited. The analysis of specific enzyme activity in cellulase preparations demonstrated that different accessory enzymes were mainly responsible for the discrepancy of enzymatic hydrolysis between diversified substrates and various cellulases. Such the active role of accessory enzymes present in cellulase preparations was finally verified by supplementation with β-glucosidase, xylanase and lytic polysaccharide monooxygenases AA9. This paper provides new insights into the role of accessory enzymes, which can further provide a useful reference for the rational customization of cellulase cocktails in order to realize an efficient conversion of natural lignocellulosic substrates. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Value of local electrogram characteristics predicting successful catheter ablation of left-versus right-sided accessory atrioventricular pathways by radiofrequency current.

    PubMed

    Lin, J L; Schie, J T; Tseng, C D; Chen, W J; Cheng, T F; Tsou, S S; Chen, J J; Tseng, Y Z; Lien, W P

    1995-01-01

    Despite similar guidance by local electrogram criteria, catheter ablation of right-sided accessory atrioventricular (AV) pathways by radiofrequency current has been less effective than that of left-sided ones. In order to elucidate the possible diversities in local electrosignal criteria, we systematically analyzed the morphological and timing characteristics of 215 bipolar local electrograms from catheter ablation sites of 65 left-sided accessory AV pathways and of 356 from those of 37 right-sided ones in 92 consecutive patients with Wolff-Parkinson-White syndrome or AV reentrant tachycardia incorporating concealed accessory AV pathways. After stepwise multivariate analysis, we selected the presence of a possible accessory pathway potential, local ventricular activation preceding QRS complex for 20 ms or more during ventricular insertion mapping, and the local retrograde ventriculoatrial (VA) continuity, local retrograde VA interval < or = 50 ms, electrogram stability (left-sided targets only), retrograde accessory pathway potential (right-sided targets only) during atrial insertion mapping, as independent local electrogram predictors for successful ablation of left- and right-sided accessory AV pathways. Combination of all local electrogram predictors could have moderate chance of success (80 and 51%) for the ventricular and atrial insertion ablation of left-sided accessory AV pathways, but only low probability of success (40% in ventricular insertion ablation) or very low sensitivity (12.5% in atrial insertion ablation) for right-sided ones. In conclusion, with the present approach, successful catheter ablation of right-sided accessory AV pathways, compared to left-sided ones, still necessitate a breakthrough in the precision mapping and the efficiency of energy delivery.