Main View
This view is used for searching all possible sources.
First Page Previous Page 1 2 Next Page Last Page
 
1
Nuclear Accident Dosimetry Systems. UK Measurements at the Fourth I.A.E.A. Intercomparison at Harwell, April 1975.
1978-01-01

An international Intercomparison of Nuclear Accident Dosimetry Systems was held at Harwell in April 1975 under the auspices of the IAEA. The source of radiation was the pulsed reactor VIPER at AWRE Aldermaston. This paper presents the results of the measu...

National Technical Information Service (NTIS)

2
1983 International Intercomparison of Nuclear Accident Dosimetry Systems at Oak Ridge National Laboratory.
1985-01-01

An international intercomparison of nuclear accident dosimetry systems was conducted during September 12-16, 1983, at Oak Ridge National Laboratory (ORNL) using the Health Physics Research Reactor operated in the pulse mode to simulate criticality acciden...

National Technical Information Service (NTIS)

3
Performance of the CEDS Accident Dosimetry System at the 1995 Los Alamos National Laboratory Nuclear Accident Dosimetry Intercomparison.
1996-01-01

In July 1995, LANL hosted an accident dosimetry intercomparison. When all reactors on the Oak Ridge Reservation were idled in 1988, the Health Physics Research Reactor (HPRR), which had been used for 22 previous intercomparisons dating from 1965, was shut...

National Technical Information Service (NTIS)

4
Technical basis for nuclear accident dosimetry at the Oak Ridge National Laboratory
1993-08-01

The Oak Ridge National Laboratory (ORNL) Environmental, Safety, and Health Emergency Response Organization has the responsibility of providing analyses of personnel exposures to neutrons and gamma rays from a nuclear accident. This report presents the technical and philosophical basis for the dose assessment aspects of the nuclear accident ...

DOE Information Bridge

5
New fixed nuclear-accident-dosimetry system for the Idaho National Engineering Laboratory
1982-06-01

A simple and inexpensive Nuclear Accident Dosimetry (NAD) system for use in criticality accidents is described in this report. It consists of activation detectors of indium, gold, copper and sulfur for neutron dose estimates and thermoluminescent dosimeters (TLD) and radiophotoluminescent (RPL) dosimeters for gamma ...

Energy Citations Database

6
NTS personnel dosimeter: NAD system
1972-12-01

The neutron dosimetry system incorporated in the NTS personnel dosimeter and the method of using it for nuclear accident dosimetry (NAD) are described. Details of the calibration procedure are given. Some useful cross sections and other detailed data are tabulated. (auth)

Energy Citations Database

7
PROCEEDINGS OF THE FIRST SYMPOSIUM ON THE NUCLEAR ACCIDENT DOSIMETRY PROGRAM: TECHNIQUES AND USES, HELD AT THE MIRAMAR CONVENTION CENTER AND THE SANTA BARBARA LABORATORY OF EDGERTON, GERMESHAUSEN AND GRIER, INC., SANTA BARBARA, CALIFORNIA, OCTOBER 5-6, 1960
1962-10-31

Proceedings of the First Symposium on the Nuclear Accident Dosimetry Programi Techniques and Uses are presented. Topics covered include justification of the general system, descriptions of gamma and neutron systems, energy-response calculations of threshold-detector unlts, radiation-leakage calculations for ...

Energy Citations Database

8
RADIATION ACCIDENTS: DOSIMETRIC ASPECTS OF NEUTRON AND GAMMA-RAY EXPOSURES
1959-11-16

A system of dosimetry for persons involved in accidental criticality excursions is presented as part A of a two part report. The information is arranged to be useful as a reference for those responsible for implementing the system. Part A also contains a review and re-evaluation of the dosimetry of ...

Energy Citations Database

9
Nuclear Accident Dosimetry: Report on the Fourth IAEA Intercomparison Experiment at Harwell, UK - 7TH-8TH April 1975: Part 1. Description of the Experiment and Participants' Results.
1976-01-01

An experiment was organised at Harwell to test nuclear accident dosimetry (NAD) systems from some 17 laboratories in 13 countries. Dosimeters were irradiated by the Viper reactor at Aldermaston which gave a well moderated neutron spectrum with a broad pea...

National Technical Information Service (NTIS)

10
Personnel neutron dosimetry
1982-04-01

This edited transcript of a presentation on personnel neutron discusses the accuracy of present dosimetry practices, requirements, calibration, dosemeter types, quality factors, operational problems, and dosimetry for a criticality accident. 32 figs. (ACR)

Energy Citations Database

11
Chemical dosimetry system for criticality accidents.
2004-01-01

Ruder Boskovi? Institute (RBI) criticality dosimetry system consists of a chemical dosimetry system for measuring the total (neutron + gamma) dose, and a thermoluminescent (TL) dosimetry system for a separate determination of the gamma ray component. The use of the chemical ...

PubMed

12
DRDC Ottawa Participation in the SILENE Accident Dosimetry ...
2002-11-01

... Accession Number : ADA412535. Title : DRDC Ottawa Participation in the SILENE Accident Dosimetry Intercomparison Exercise. June 10-21, 2002. ...

DTIC Science & Technology

13
Panasonic dosimetry system performance testing and results at nuclear accident dose levels 500 rad to 10,000 rad.
1998-01-01

Panasonic thermoluminescent dosimeters (TLDs) are used as the photon dose assessment part of the personal nuclear accident dosimeter (PNAD) and may be used for the same purpose with the fixed nuclear accident dosimeter (FNAD). To demonstrate compliance wi...

National Technical Information Service (NTIS)

14
Reference dosimetry measurements for the international intercomparison of criticality accident dosimetry SILENE 9-21 June 2002.
2004-01-01

An international intercomparison of criticality accident dosimetry systems took place in the SILENE reactor, in June 2002. Participants from 60 laboratories irradiated their dosemeters (physical and biological) using two different configurations of the reactor. In preparation for this intercomparison, the leakage radiation fields were ...

PubMed

15
Dosimetry of Criticality Accidents Using Activations of the Blood and Hair.
1980-01-01

The evaluation of the dose that a person received in a criticality accident can be difficult. Most accidents have occurred when the person was not wearing nuclear accident dosimetry and since the NRC no longer requires these dosimeters, future dose evalua...

National Technical Information Service (NTIS)

16
10 CFR 835.1304 - Nuclear accident dosimetry.
2011-01-01

... OCCUPATIONAL RADIATION PROTECTION ...835.1304 Nuclear accident dosimetry...individuals to radiation from a nuclear accident is possible...involved in a nuclear accident to determine...significant exposures to radiation occurred;...

Code of Federal Regulations, 2011

17
Seventeenth nuclear accident dosimetry intercomparison study: August 11-15, 1980
1981-04-01

The Seventeenth Nuclear Accident Dosimetry Intercomparison Study was conducted August 11-15, 1980, at the Oak Ridge National Laboratory. Nuclear criticality accidents with three different neutron and gamma ray energy spectra were simulated by operating the Health Physics Research Reactor in the pulse mode. Participants from 13 ...

Energy Citations Database

18
The ENEA criticality accident dosimetry system: a contribution to the 2002 international intercomparison at the SILENE reactor.
2004-01-01

The present paper summarises the activity carried out at the ENEA Radiation Protection Institute for updating the methodologies employed for the evaluation of the neutron and photon dose to the exposed workers in case of a criticality accident, in the framework of the 'International Intercomparison of Criticality Accident Dosimetry ...

PubMed

19
An upgraded personnel dosimetry system for TMI-2 (Three Mile Island Unit 2)
1988-01-01

Following the Three Mile Island Unit 2 (TMI-2) accident, it was identified that due to the unusual radiological conditions created, an improved thermoluminescent dosimetry (TLD) system was needed to support the cleanup and recovery. The deficiencies of the existing system were identified as an unsuitable dosimeter ...

Energy Citations Database

20
La dosimetrie biologique des accidents d'irradiation. (Biological dosimetry of irradiation accidents).
1994-01-01

The biological dosimetry in radiation protection allows to evaluate the received dose by a potentially irradiated person from biological markers such chromosomal abnormalities. The technologies of Hybridization In Situ by Fluorescence (F.I.S.H) allow the ...

National Technical Information Service (NTIS)

First Page Previous Page 1 2 Next Page Last Page
 
First Page Previous Page 1 2 Next Page Last Page
 
21
Optoelectronic reader for CET dosimeter, a radiation accident chemical dosimetry system
2003-12-01

The use of chlorobenzene-ethanol-trimethylpentane solution (CET) in radiation dosimetry is based on radiolytic formation of hydrochloric acid which protonates a pH indicator, thymolsulphonphthalein. The high molar absorptivity of its red form at 552nm is responsible for a high sensitivity of the system: doses in the range 0.2-15Gy can be measured. Together ...

NASA Astrophysics Data System (ADS)

22
Czech results at criticality dosimetry intercomparison 2002.
2004-01-01

Two criticality dosimetry systems were tested by Czech participants during the intercomparison held in Valduc, France, June 2002. The first consisted of the thermoluminescent detectors (TLDs) (Al-P glasses) and Si-diodes as passive neutron dosemeters. Second, it was studied to what extent the individual dosemeters used in the Czech routine personal ...

PubMed

23
Twenty-second ORNL intercomparison of criticality accident dosimetry systems, August 12-16, 1985
1986-05-01

The twenty-second in a series of criticality accident dosimetry intercomparison studies was conducted at the Oak Ridge National Laboratory's Dosimetry Applications Research Facility during August 12-16, 1985. The Health Physics Research Reactor operated in the pulse mode over Storage Pit No. 1 was used to simulate three ...

Energy Citations Database

24
The 1983 international intercomparison of nuclear accident dosimetry systems at Oak Ridge National Laboratory
1985-04-01

An international intercomparison of nuclear accident dosimetry systems was conducted during September 12 to 16, 1983, at Oak Ridge National Laboratory (ORNL) using the Health Physics Research Reactor operated in the pulse mode to simulate criticality accidents. Participants measured neutron and gamma doses at area ...

NASA Astrophysics Data System (ADS)

25
Performance of the CEDS Accident Dosimetry System at the 1995 Los Alamos National Laboratory Nuclear Accident Dosimetry Intercomparison
1996-12-01

In July 1995, LANL hosted an accident dosimetry intercomparison. When all reactors on the Oak Ridge Reservation were idled in 1988, the Health Physics Research Reactor (HPRR), which had been used for 22 previous intercomparisons dating from 1965, was shut down for an indefinite period. The LANL group began characterization of two critical assemblies for ...

DOE Information Bridge

26
Nineteenth nuclear accident dosimetry intercomparison study, August 9-13, 1982
1983-11-01

The Nineteenth Nuclear Accident Dosimetry Intercomparison Study was held August 9 to 13, 1982, at the Oak Ridge National Laboratory using the Health Physics Research Reactor operated in the pulse mode to simulate nuclear criticality accidents. Participants from eight organizations measured neutron and gamma doses at air stations and on ...

Energy Citations Database

27
Criticality accident dosimetry systems: an international intercomparison at the SILENE reactor in 2002.
2004-01-01

In criticality accident dosimetry and more generally for high dose measurements, special techniques are used to measure separately the gamma ray and neutron components of the dose. To improve these techniques and to check their dosimetry systems (physical and/or biological), a total of 60 laboratories from 29 ...

PubMed

28
The Theory and Practice of Radiation Dosimetry in the ...
1987-04-01

... Title : The Theory and Practice of Radiation Dosimetry in the Radiation Hardness Testing of Electronic Devices and Systems. ...

DTIC Science & Technology

29
Personnel neutron dosimetry at SLAC
1975-06-09

The rationale and methods of the personnel neutron-dosimetry system used at SLAC are presented and discussed.

Energy Citations Database

30
Performance characteristics of a high-level solid-state personnel dosimetry system in pulsed radiation environments
1986-01-01

The Health Physics Research Reactor at Oak Ridge National Laboratory was used to evaluate performance characteristics of a high-level, solid-state, personnel-dosimetry system developed for the US Army for the rapid measurement of total(gamma plus neutron) radiation doses to soldiers in locations where tactical nuclear weapons could be used. The ...

Energy Citations Database

31
Dosimetry at the Los Alamos Critical Experiments Facility: Past, present, and future
1993-10-01

Although the primary reason for the existence of the Los Alamos Critical Experiments Facility is to provide basic data on the physics of systems of fissile material, the physical arrangements and ability to provide sources of radiation have led to applications for all types of radiation dosimetry. In the broad definition of radiation phenomena, the ...

Energy Citations Database

First Page Previous Page 1 2 Next Page Last Page