Main View
This view is used for searching all possible sources.
First Page Previous Page 1 2 3 4 5 6 7 Next Page Last Page
 
1
SNS LINAC Wire Scanner System : Signal Levels and Accuracy.
2002-01-01

The linac wire scanner system for the Spallation Neutron Source (SNS) at Oak Ridge, TN, USA, calls for 5 units in the medium energy beam transport (MEBT), 5 in the drift tube linac (DTL), and 10 in the coupled cavity linac (CCL). In this paper we present expected signal levels and an analysis of the error in the beam size measurement as functions of ...

Energy Citations Database

2
Wire-Scanner Recentering Experiment Error Estimates.
1977-01-01

In the wire-scanner recentering experiment, the effective center of a wire scanner is determined by turning the previous quadrupole magnet on and off. The beam is steered into the quadrupole such that it drifts to the same point somewhere on a second wire...

National Technical Information Service (NTIS)

3
Premier Scanner a Fils Chauds (Initial Model of a Hot-Wire Scanner).
1989-01-01

The authors present the results of a feasibility study for the fabrication of a hot-wire mini-scanner. After reviewing what scanning and hot-wire scanning entail, they describe a simple physical study of the system. They then present the solution algorith...

National Technical Information Service (NTIS)

4
Experience with wire scanners at SLC.
1992-01-01

Fifty wire scanners are in use at SLC for phase space and beam optics monitoring. A large number of failures of the 50 (mu)m wire used in the scanners have occurred. Studies of these show strong electro-magnetic fields produced by the beam to be the proba...

National Technical Information Service (NTIS)

5
BEPC II wire scanner system
2010-10-01

To monitor the beam profile at the end of the linac non-destructively, a wire scanner as a new diagnostic instrument was designed, manufactured and installed in 2007. Since then, several measurements have been carried out using this device. This paper describes the whole system of the wire scanner and the testing ...

NASA Astrophysics Data System (ADS)

6
LASER SCANNER FOR AUTOMATIC INSPECTION OF ...
1980-10-01

... Accession Number : ADD312291. Title : LASER SCANNER FOR AUTOMATIC INSPECTION OF PRINTED WIRING BOARDS. Corporate Author : ...

DTIC Science & Technology

7
Design and simulation of a wire scanner for the CSNS linac
2010-10-01

In this paper, we report the design and simulation of a wire scanner for the linac of the CSNS (China Spallation Neutron Source). The wire scanner is used to measure the transverse beam profile and the emittance. The effect of beam energy change upon the mechanical design of the wire ...

NASA Astrophysics Data System (ADS)

8
An Instrument Design for the Accurate Determination of the Electron Beam Location in the Linac Coherent Light Source Undulator
2008-01-23

The Linac Coherent Light Source (LCLS), currently under design, requires accurate alignment between the electron beam and each undulator's magnetic centerline. A beam finder wire (BFW) instrument has been developed to provide beam location information that is used to move the undulators to their appropriate positions. A BFW instrument is mounted at each of the 33 ...

DOE Information Bridge

9
Rhic Beam Position Monitor Characterization
1995-01-01

Techniques and results of RHIC BPM measurements are presented. These include wire scanner measurements of uncalibrated and calibrated BPM position and roll accuracy, preliminary measurements of the coupling between adjacent striplines to permit in situ offset calibration of the BPM signal cables and electronics, frequency dependence of ...

E-print Network

10
Beam energy measurement using the ARC beam line as a spectrometer
1993-06-01

The use of the Hall C achromatic arc line as an energy analyser is proposed. It has a dispersion of 12cm/% with all the quadrupoles, sextupoles, and beam correctors switched off. The transverse position and the angle of the beam at the entrance of the arc is precisely measured by a pair of wire scanners spaced by 2.5 m, and the transverse position of the ...

DOE Information Bridge

11
DOUBLE-UNIT AUTOMATIC FLUX WIRE SCANNER
1959-09-01

A double-unit automatic flux wire scanner was designed and put into operation for use in obtdining neutron flux profiles by the activation technique. The instrument consists of two scanner assemblies with the necessary information and a central control unit. Each scanner assembly consists of a stationary ...

Energy Citations Database

12
Evaluation and Accuracy Assessment of ANDSCAN - A ...
1995-05-01

... Accession Number : ADD338291. Title : Evaluation and Accuracy Assessment of ANDSCAN - A Portable Non-Destructive Scanner. ...

DTIC Science & Technology

13
TS2 Terrestrial Laser Scanning Thorsten Schulz and Hilmar Ingensand

, Precision and Accuracy of Terrestrial Laser Scanners INGEO 2004 and FIG Regional Central and Eastern Variables, Precision and Accuracy of Terrestrial Laser Scanners Thorsten SCHULZ and Hilmar INGENSAND, laser scanning is used for applications in cultural heritage. The recent developments of laser ...

E-print Network

14
Lansce Wire Scanning Diagnostics Device Mechanical Design
2011-01-01

The Accelerator Operations & Technology Division at Los Alamos National Laboratory operates a linear particle accelerator which utilizes 110 wire scanning diagnostics devices to gain position and intensity information of the proton beam. In the upcoming LANSCE improvements, 51 of these wire scanners are to be replaced with a new ...

Energy Citations Database

15
INTEGRATED LASER SCANNER AND INTENSITY IMAGE CALIBRATION AND ACCURACY ASSESSMENT

INTEGRATED LASER SCANNER AND INTENSITY IMAGE CALIBRATION AND ACCURACY ASSESSMENT Jafar Amiri Parian (parian, agruen)@geod.baug.ethz.ch KEY WORDS: Laser Scanner, Panoramic Image, Calibration, Sensor, Modeling, Accuracy, Test ABSTRACT: Nowadays, the use of laser scanner devices as an active ...

E-print Network

16
Experience with wire scanners at SLC
1992-12-01

Fifty wire scanners are in use at SLC for phase space and beam optics monitoring. A large number of failures of the 50 [mu]m wire used in the scanners have occurred. Studies of these show strong electro-magnetic fields produced by the beam to be the probable cause. The problem has been cured with the adoption of a ...

DOE Information Bridge

17
Experience with wire scanners at SLC
1992-12-01

Fifty wire scanners are in use at SLC for phase space and beam optics monitoring. A large number of failures of the 50 {mu}m wire used in the scanners have occurred. Studies of these show strong electro-magnetic fields produced by the beam to be the probable cause. The problem has been cured with the adoption of a ...

DOE Information Bridge

18
Cost effective system for connecting multiwire cables to printed wiring boards
1980-03-01

A system flexible enough to meet present and future work requirements was developed. The Component Locator System usually is referred to as a Work Director. The Work Director shows the exact location for installing the wire on the pointed wiring board (PWB) and codes the Cable Scanner for the correct wire. The ...

NASA Astrophysics Data System (ADS)

19
Wire-scanner recentering experiment error estimates
1977-09-01

In the wire-scanner recentering experiment, the effective center of a wire scanner is determined by turning the previous quadrupole magnet on and off. The beam is steered into the quadrupole such that it drifts to the same point somewhere on a second wire scanner downstream, for the quadrupole ...

Energy Citations Database

20
A Novel Wire Scanner for High Intensity Pulsed Beams
1999-02-19

A novel wire scanner has been developed with applications at linear accelerators where small beam spots or high intensities would otherwise destroy wires. A pattern of wires is supported on a thin membrane and remains in place even when punctured by the beam. Many scans can be made before the material needs to be ...

DOE Information Bridge

First Page Previous Page 1 2 3 4 5 6 7 Next Page Last Page
 
First Page Previous Page 1 2 3 4 5 6 7 Next Page Last Page
 
21
Wire breakage in SLC wire profile monitors.
1998-01-01

Wire scanning beam profile monitors are used at the Stanford Linear Collider (SLC) for emittance preservation control and beam optics optimization. Twenty such scanners have proven most useful for this purpose and have performed a total of 1.5 million sca...

National Technical Information Service (NTIS)

22
Cost effective system for connecting multiwire cables to printed wiring boards. Final report
1980-03-01

The high density wiring used on newer electronic devices requires an improved processing technique to eliminate wiring errors and difficulties in reworking assemblies. For example, one subassembly has three cables and three connectors containing approximately 130 wires that terminate on a printed wiring board ...

Energy Citations Database

23
Absolute Accuracy of the Cyberware WB4 Whole Body Scanner.
1997-01-01

This report describes a study of the accuracy of the Cyberware WB4 whole-body scanner. CARD Lab researchers made multiple scans of a calibration object designed to simulate human body size and shape. Researchers then pinpointed landmarks on the scans usin...

National Technical Information Service (NTIS)

24
Wall Sensing for an Autonomous Robot With a Three ...
2011-02-01

... measurement. This technique retains much of the accuracy of the line scanner and can generate a very dense point cloud. The ...

DTIC Science & Technology

25
Reverse Engineering of Quadric Surfaces Employing Three ...

... Examples of the accuracy of the laser scanner data, and software algorithms for modelling planes, cylinders, cones and spheres, are presented by ...

DTIC Science & Technology

26
Measuring Household Food Inventory with a UPC Scanner is ...

... method of recording the home food inventory the accuracy and simplicity of this approach can provide useful information on foods available for ...

DTIC Science & Technology

27
Accuracy of Ocean Color Data Derived from the Coastal Zone ...
1991-03-01

Page 1. AD-A235 719 Accuracy of Ocean Color Data Derived from the Coastal Zone Color Scanner (CZCS) GD ...

DTIC Science & Technology

28
Accuracy of Ocean Color Data Derived from the Coastal Zone ...
1991-03-01

... Accession Number : ADA235719. Title : Accuracy of Ocean Color Data Derived from the Coastal Zone Color Scanner (CZCS). ...

DTIC Science & Technology

29
THE STANDARD BASE LINE AND AN INVESTIGATION OF ...

... Title : THE STANDARD BASE LINE AND AN INVESTIGATION OF READING ACCURACY IN BASE LINE MEASUREMENT WITH INVAR WIRES,. ...

DTIC Science & Technology

30
Accuracy of Reduced and Extended Thin-Wire Kernels
2008-11-24

Some results are presented comparing the accuracy of the reduced thin-wire kernel and an extended kernel with exact integration of the 1/R term of the Green's function and results are shown for simple wire structures.

Energy Citations Database

31
A laser range scanner designed for minimum calibration complexity
2001-01-01

Laser range scanners are a popular method for acquiring three-dimensional geometry due to their accuracy and robustness. Maximizing scanner accuracy while minimizing engineering costs is a key challenge to future scanner designs. Engineering costs arise from both expensive components and ...

E-print Network

32
Determination of transverse phase-space and momentum error from size measurements along the 50-MeV H/sup -/ RCS injection line
1981-01-01

The 50-MeV H/sup -/ injection line for the RCS at Argonne National Laboratory has 16 quadrupole and eight bending magnets. Horizontal and vertical profiles can be obtained at 12 wire scanner positions. Size information from these profiles can be used to determine the three ellipses parameters in each plane required to describe the transverse phase space. ...

DOE Information Bridge

33
Beam emittance measurements in RHIC
2009-05-04

The RHIC proton polarimeters can operate in scanning mode, giving polarization profiles and transverse beam intensity profile (beam emittance) measurements. The polarimeters function as wire scanners, providing a very good signal/noise ratio and high counting rate. This allows accurate bunch-by-bunch emittance measurements during fast target sweeps ...

DOE Information Bridge

34
Relation between Wire Resistance and Fluid Pressure in the Transient Hot-Wire Method,
1989-01-01

The resistance of metals is a function of applied pressure, and the dependence is large enough to be significant in the calibration of transient hot-wire thermal conductivity instruments. For the highest possible accuracy, the instrument's hot wires shoul...

National Technical Information Service (NTIS)

35
Approximations to wire grid inductance.
2004-06-01

By using a multipole-conformal mapping expansion for the wire currents we examine the accuracy of approximations for the transfer inductance of a one dimensional array of wires (wire grid). A simple uniform fit is constructed by introduction of the decay factor from bipolar coordinates into existing formulas for ...

Energy Citations Database

36
Fostering a Project Management Legacy through Technology ... - NASA

scanners, automatic insulin pump, portable x-ray device, invisible braces, dental arch wire, palate surgery technology, clean room apparel, implantable ...

NASA Website

37
Design and control of a nanoprecision XY? scanner
2008-04-01

This paper describes the design and control of a nanoprecision XY? scanner consisting of voice coil motors and air bearing guides. The proposed scanner can be installed on a conventional XY stage with long strokes to improve the positioning accuracy and settling performance. Major design considerations in developing a high precision ...

NASA Astrophysics Data System (ADS)

38
Design and control of a nanoprecision XY Theta scanner.
2008-04-01

This paper describes the design and control of a nanoprecision XY Theta scanner consisting of voice coil motors and air bearing guides. The proposed scanner can be installed on a conventional XY stage with long strokes to improve the positioning accuracy and settling performance. Major design considerations in developing a high ...

PubMed

39
SPIE Proceedings on Iiitelligent Trunsportution Systems, I99 High-performance laser range scanner

SPIE Proceedings on Iiitelligent Trunsportution Systems, I99 High-performance laser range scanner, PA 15110 ABSTRACT Laser scanners, or ladars, have been used for a number of years for mobile robot of state-of-the-art, high speed, high accuracy, laser range scanner technology This work has been a joint

E-print Network

40
Accuracy of 3D Scanning Technologies in a Face Scanning Scenario Chris Boehnen Patrick Flynn

that is generally accepted. Goesele et al. [2] compared the accuracy of two laser scanners using a slanted edge of the resulting scan. Subject comfort is comparable to the other scanners reviewed. The laser used is also eye] sandpaper function (the translucency of the eyes can cause spikes when using a laser ...

E-print Network

First Page Previous Page 1 2 3 4 5 6 7 Next Page Last Page
 
First Page Previous Page 1 2 3 4 5 6 7 Next Page Last Page
 
41
Wire scanners for beam size and emittance measurements at the SLC
1991-05-01

The SLC wire scanner beam profile monitors provide accurate beam size and emittance measurements for each bunch in the three bunch SLC beam. The beam size measurement error for typical 50GeV SLC linac beams (100{mu}m {sigma}({sub x,y})) is better than 5{mu}m. Beam profile measurements can be performed throughout much of the SLC with no interruption to ...

DOE Information Bridge

42
Design and development of the LEDA slow wire scanner profile measurement
1998-12-31

The Low Energy Demonstration Accelerator (LEDA) is being developed at Los Alamos National Laboratory as part of the Accelerator Production of Tritium (APT) project. One of the diagnostics being developed to commission LEDSA is a slow wire scanner beam profile measurement. Initial profile measurements will be made at 6.7 MeV beam energy and 100 mA beam ...

Energy Citations Database

43
Design and Development of the LEDA Slow Wire Scanner Profile Measurement
1998-08-31

The Low Energy Demonstration Accelerator (LEDA) [1, 2] is being developed at Los Alamos National Laboratory as part of the Accelerator Production of Tritium (APT) project. One of the diagnostics being developed to commission LEDA [3] is a slow wire scanner beam profile measurement. Initial profile measurements will be made at 6.7 MeV beam energy and 100 mA ...

Energy Citations Database

44
Wire scanner software and firmware issues
2008-01-01

The Los Alamos Neutron Science Center facility presently has 110 slow wire scanning profile measurement instruments located along its various beam lines. These wire scanners were developed and have been operating for at least 30 years. While the wire scanners solved many problems to operate and ...

Energy Citations Database

45
Accuracy and directional sensitivity of the single-wire technique
1984-01-01

Multi-orientation of a single-hot-wire is a novel way to measure the three time-mean velocities, the

NASA Technical Reports Server (NTRS)

46
Interpolation of High Quality Ground Models From Laser Scanned Data in Forested Areas

... presented, but this list has also validity for laser scanner data processing in general. The quality of the DTMs derived from laser scanner data and accuracy investigations are presented for two ... ...

NBII National Biological Information Infrastructure

47
A Study of Techniques for Processing Multispectral Scanner Data.
1973-01-01

A linear decision rule to reduce the time required for processing multispectral scanner data is developed. Test results are presented which justify the use of the new rule for digital processing whenever both accuracy and processing time are important. A ...

National Technical Information Service (NTIS)

48
Model of Carbon Wire Heating in Accelerator Beam

A heat flow equation with beam-induced heating and various cooling processes for a carbon wire passing through a particle beam is solved. Due to equation nonlinearity a numerical approach based on discretization of the wire movement is used. Heating of the wire due to the beam-induced electromagnetic field is taken into account. An ...

E-print Network

49
Wire scanners for beam size and emittance measurements at the SLC.
1991-01-01

The SLC wire scanner beam profile monitors provide accurate beam size and emittance measurements for each bunch in the three bunch SLC beam. The beam size measurement error for typical 50GeV SLC linac beams (100(mu)m (sigma)((sub x,y))) is better than 5(m...

National Technical Information Service (NTIS)

50
Wire scanner data analysis for the SSC Linac emittance measurement
1993-07-01

The wire scanners are designed in the SSC Linac for measurement of beam emittance at various locations. In order to obtain beam parameters from the scan signal, a data analysis program was developed that considers the problems of noise reduction, machine modeling, parameter fitting, and correction. This program is intended as a tool for Linac commissioning ...

DOE Information Bridge

51
First Test Results of the New LANSCE Wire Scanner
2011-01-01

The Beam Diagnostics and Instrumentation Team (BDIT) at Los Alamos National Laboratory's LANSCE facility is presently developing a new and improved wire scanner diagnostics system controlled by National Instrument's cRIO platform. This paper describes the current state of development of the control system along with the results gathered ...

Energy Citations Database

52
DETERMINING PHASE-SPACE PROPERTIES OF THE LEDA RFQ OUTPUT BEAM
2000-08-01

Quadruple scans were used to characterize the LEDA RFQ beam. Experimental data were fit to computer simulation models for the rms beam size. The codes were found to be inadequate in accurately reproducing details of the wire scanner data. When this discrepancy is resolved, we plan to fit using all the data in wire ...

DOE Information Bridge

53
Practical transverse matching of the high-intensity SNS Linac
2009-08-01

It is important to accomplish adequate matching for a high intensity linear accelerator such as the SNS linac to minimize the mismatch and potential beam loss. In the early stage of the SNS linac design, there was a discussion over whether to match the core or to match the tail. The present study shows that the matching by minimizing rms emittances reduces both the core emittance and the beam ...

NASA Astrophysics Data System (ADS)

54
Design considerations for a novel MRI compatible manipulator for prostate cryoablation.
2011-04-12

PURPOSE: Prostate carcinoma is a commonly diagnosed cancer in men. Nonsurgical treatment of early stage prostate cancer is an important alternative. The use of MRI for tumor cryoablation is of particular interest: it offers lower morbidity compared with other localized techniques. However, the current manual procedure is very time-consuming and has limited accuracy. A novel ...

PubMed

55
Measuring micron size beams in the SLC final focus
1994-10-01

A pair of high resolution wire scanners have been built and installed in the SLC final focus. The final focus optics uses a set of de-magnifying telescopes, and an ideal location for a beam size monitor is at one of the magnified image points of the interaction point. The image point chosen for these scanners is in the middle of a ...

Energy Citations Database

56
Figures of merit for comparing reconstruction algorithms with a volume-imaging PET scanner.
1994-03-01

For volume-imaging PET scanners, no septa are used to maximize the sensitivity by collecting events oblique to the scanner axis. We answer two questions: (i) how does the performance of an image reconstruction algorithm for a volume-imaging PET scanner depend on its general dimensions? and (ii) at what point is a three-dimensional (3D) ...

PubMed

57
Wire breakage in SLC wire profile monitors
1998-05-01

Wire scanning beam profile monitors are used at the Stanford Linear Collider (SLC) for emittance preservation control and beam optics optimization. Twenty such scanners have proven most useful for this purpose and have performed a total of 1.5 million scans in the 4 to 6 years since their installation. Most of the essential scanners ...

DOE Information Bridge

58
GEOPOSITIONAL ACCURACY ASSESSMENT OF EARTHSAT ...

historical time frames: (l) mid-1970s imagery from the Landsat Multispectral Scanner (MSS); (2) late 19805 ~ early l990s imagery from the Landsat Thematic ...

NASA Website

59
Autoradiography of californium-252 wire neutron sources. [To determine uniformity of distribution of Cf 252
1976-03-01

A technique for measuring the distribution of Cf 252 in a wire is discussed. An autograph was produced by placing the wire on a photographic plate sensitive to gamma radiation. The radiograph was read by a computer automated densitometer. A brief discussion of the accuracy of the technique is presented. (DDA)

Energy Citations Database

60
The Recent Results of the ATF
2003-03-14

This report describes the recent results of the beam commissioning of the ATF at KEK. Recent progress on the studies on production of low emittance beam, multi-bunch beam operation and development on beam instrumentation are discussed. So far, a horizontal emittance of 1.7 {+-} 0.3 nm was measured with wire-scanners in the extraction line and with the horizontal spatial ...

Energy Citations Database

First Page Previous Page 1 2 3 4 5 6 7 Next Page Last Page
 
First Page Previous Page 1 2 3 4 5 6 7 Next Page Last Page
 
61
LANSCE-R WIRE-SCANNER SYSTEM
2011-01-01

The National Instruments cRIO platform is used for the new LANSCE-R wire-scanner systems. All wire-scanner electronics are integrated into a single BiRa BiRIO 4U cRIO chassis specifically designed for the cRIO crate and all interface electronics. The BiRIO chassis, actuator and LabVIEW VIs provide a complete wire-scanner system ...

Energy Citations Database

62
Test Measurements of a 20 ms-1 Carbon Wire Beam Scanner

This paper pre�sents the de�sign of the ac�tu�a�tor for the fast and high ac�cu�ra�cy Wire Scan�ner sys�tem. The ac�tu�a�tor con�sists of a ro�tary brushless syn�chronous motor with the per�ma�nent mag�net rotor in�stalled in�side the vac�u�um cham�ber and the sta�tor in�stalled ...

E-print Network

63
Nondestructive measurement of solar cell sheet resistance using a laser scanner
1984-05-01

Experimental data have shown that a laser scanner can be used as a probe to make nondestructive measurements of solar cell sheet resistance with an accuracy of several percent. The photovoltaic response from cells with controlled sheet resistance was measured using the scanner and compared with the theoretical predictions made by other ...

Energy Citations Database

64
Measuring Household Food Inventory with a UPC Scanner is a Feasible Method of Studying Food Usage Patterns in Low Income Families.
2003-01-01

This study determines the feasibility of using a UPC scanner to record the home food inventory of limited-resource families. Feasibility is based on the accuracy of the scanner, time involved, and researcher/study participant feedback. Program staff used ...

National Technical Information Service (NTIS)

65
Detection of electrical problems using an infrared scanner
1982-01-01

A valuable tool of preventive maintenance in electrical systems is the use of infrared surveys. Infrared scanners detect problems which produce an abnormal rise in temperature. Because electrical equipment is scanned while it is in service, actual operating conditions are observed. The ability to determine the amount of temperature rise is important in establishing priorities ...

Energy Citations Database

66
Geopositional Accuracy Validation of Orthorectified Landsat MSS Imagery.
2004-01-01

This report provides results of an independent assessment of the horizontal geopositional accuracy of Earth Satellite (EarthSat) Corporation's GeoCover orthorectified Landsat Multispectral Scanner (MSS) imagery. This imagery was purchased through NASA's E...

National Technical Information Service (NTIS)

67
Additional Studies of Forest Classification Accuracy as Influenced by Multispectral Scanner Spatial Resolution.
1976-01-01

First, an analysis of forest feature signatures was used to help explain the large variation in classification accuracy that can occur among individual forest features for any one case of spatial resolution and the inconsistent changes in classification a...

National Technical Information Service (NTIS)

68
Accuracy and precision of the three-dimensional assessment of the facial surface using a 3-D laser scanner.
2006-06-01

Three-dimensional (3-D) recording of the surface of the human body or anatomical areas has gained importance in many medical specialties. Thus, it is important to determine scanner precision and accuracy in defined medical applications and to establish standards for the recording procedure. Here we evaluated the precision and accuracy ...

PubMed

69
Enhancing laser scanner accuracy by grid correction
2010-02-01

Lasers are used in micro manufacturing and microwelding applications. Manufacturing in micrometer scale features requires good laser beam properties, but also the axes of the laser machining system have to be accurate. One of the possible technologies is a scanner. Scanners are equipped often with galvanometric actuators, which enable accurate beam ...

NASA Astrophysics Data System (ADS)

70
Factors affecting accuracy and precision in PET volume imaging
1991-03-01

Volume imaging positron emission tomographic (PET) scanners with no septa and a large axial acceptance angle offer several advantages over multiring PET scanners. A volume imaging scanner combines high sensitivity with fine axial sampling and spatial resolution. The fine axial sampling minimizes the partial volume effect, which affects ...

Energy Citations Database

71
Linac beam core modeling from wire-scanner data
1977-08-01

This study introduces mathematical modeling of accelerator beams from data collected by wire scanners. Details about a beam core D(x,x',y,y') are examined in several situations: (a) for a discretization of the projection into xy-space, a maximum-entropy solution and a minimum-norm solution are developed and discussed, (b) for ...

Energy Citations Database

72
BEAM EMITTANCE MEASUREMENT TOOL FOR CEBAF OPERATIONS
2008-10-01

A new software tool was created at Jefferson Lab to measure the emittance of the CEBAF electron beams. The tool consists of device control and data analysis applications. The device control application handles the work of wire scanners and writes their measurement results as well as the information about accelerator settings during these measurements into ...

Energy Citations Database

73
ANALYSIS OF DATA FROM THE LEDA WIRE SCANNER/HALO SCRAPER
2001-05-01

A new diagnostic has been designed and commissioned that measures the profile of the beam in the halo channel of the Low Energy Demonstration Accelerator at the Los Alamos National Laboratory. This paper describes the algorithms written to analyze the data from that diagnostic, a combined wire scanner and halo scraper. These algorithms determine the safe ...

Energy Citations Database

74
Commercial scanner application for reverse engineering and inspection
1997-01-01

A commercial scanner provides economical and extremely accurate images. This paper discuses the scanner and how it is used in the CGI RE1000 reverse engineering and inspection system. The RE1000 complements existing laser, CMM, and x- ray technologies. The RE1000 provides greater accuracy, captures complete internal geometry, and is ...

NASA Astrophysics Data System (ADS)

75
Quantitative x-ray microtomography with a conventional source
2010-08-01

In 1981, Elliott and Dover designed an X-ray microtomography scanner as a means of measuring the local mineral concentration in teeth. Although slow, this first generation system gave accurate measurements of the X-ray linear attenuation coefficient (LAC) due to its use of energy dispersive photon counting apparatus. Attaining such accuracy with ...

NASA Astrophysics Data System (ADS)

76
Development of Response Models for the Earth Radiation Budget Experiment (ERBE) Sensors. Part 3. ERBE Scanner Measurement Accuracy Analysis due to Reduced Housekeeping Data.
1987-01-01

The accuracy of scanner measurements was evaluated when the sampling frequency of sensor housekeeping (HK) data was reduced from once every scan to once every eight scans. The resulting increase in uncertainty was greatest for sources with rapid or extrem...

National Technical Information Service (NTIS)

77
Scanner-dependent optical proximity effects
2009-03-01

Optical imaging of IC critical designs is impacted by optical proximity effects, OPEs, originating from finite numerical aperture of projection lenses used in modern projectors. The OPE's are caused by filtering of pattern diffraction orders falling outside of the lens band pass. Controlling OPEs is so critical to IC performance, that IC design community implemented optical proximity correction, ...

NASA Astrophysics Data System (ADS)

78
Beam Emittance Measurement with Laser Wire Scanners in the ILC Beam Delivery System
2008-02-01

Accurate measurement of the beam phase-space is essential for the next generation of electron accelerators. A scheme for beam optics optimization and beam matrix reconstruction algorithms for the diagnostics section of the beam delivery system of the International Linear Collider based on laser-wire beam profile monitors are discussed. Possible modes of operation of the ...

DOE Information Bridge

79
Beam profile wire-scanner/halo-scraper sensor analog interface electronics
2001-04-01

The halo experiment presently being conducted at the Low Energy Demonstration Accelerator (LEDA) at Los Alamos National Laboratory utilizes a generally traditional wire scanner for measurement of the beam core profile and a graphite scraper for measurement of the tails of the beam distribution. A lossy integrator is used to detect the replacement charge ...

Energy Citations Database

80
Transverse tails and higher order moments.
1993-01-01

The tails that may be engendered in a beam's transverse phase space distribution by, e.g., intrabunch wakefields and nonlinear magnetic fields, are all important diagnostic and object of tuning in linear colliders. Wire scanners or phosphorescent screen m...

National Technical Information Service (NTIS)

First Page Previous Page 1 2 3 4 5 6 7 Next Page Last Page
 
First Page Previous Page 1 2 3 4 5 6 7 Next Page Last Page
 
81
Physics requirements of commissioning diagnostics for SSCL linac.
1993-01-01

Commissioning diagnostics are described in terms of the beam physics requirements of the SSCL linac. Commissioning diagnostics include current monitors, beam position monitors, spectrometer, foil scattering experiment, wire scanners, Faraday cups, and bun...

National Technical Information Service (NTIS)

82
Parabolic Trough VSHOT Optical Characterization in 2005-2006...
2006-08-14

reports errors relative to that shape Target FireWire Camera Test Article He/Ne Laser Laser Scanner Tripod Camera Support Arms Control Computer Shutter Laser "Spot" Solargenix...

National Renewable Energy Laboratory (NREL)

83
Concentrator Testing
2007-03-16

reports errors relative to that shape Target FireWire Camera Test Article He/Ne Laser Laser Scanner Tripod Camera Support Arms Control Computer Shutter Laser "Spot" page 20...

National Renewable Energy Laboratory (NREL)

84
BEAM-PROFILE INSTRUMENTATION FOR BEAM-HALO MEASUREMENT : OVERALL DESCRIPTION, OPERATION, AND BEAM DATA.
2001-01-01

The halo experiment presently being conducted at the Low Energy Demonstration Accelerator (LEDA) at Los Alamos National Laboratory (LANL) has specific instruments that acquire horizontally and vertically projected particle-density beam distributions out to greater than 10{sup 5}:1 dynamic range. They measure the core of the distributions using traditional wire ...

Energy Citations Database

85
LANSCE wire scanning diagnostics device mechanical design
2010-01-01

The Los Alamos Neutron Science Center (LANSCE) is one of the major experimental science facilities at the Los Alamos National Laboratory (LANL). The core of LANSCE's work lies in the operation of a powerful linear accelerator, which accelerates protons up to 84% the speed oflight. These protons are used for a variety of purposes, including materials testing, weapons research and isotopes ...

Energy Citations Database

86
Measured emittance versus store time in the SLC damping ring
1992-03-01

Emittance studies at the SLC North Damping Ring led to precise measurements of the damping time using three independent methods. These measurements were done at three different locations: (1) in the ring using a fast gated video camera which allows the acquisition of the image of the synchrotron light from a single turn, (2) using the extracted beam and a single wire ...

Energy Citations Database

87
Characterizing proton beam of 6.7 MeV LEDA RFQ by fitting wire-scanner profiles to 3-D nonlinear simulations
2001-01-01

Quadrupole scans were used to characterize the transverse beam of the LEDA RFQ. The original scan data, obtained when the HEBT was installed immediately downstream of the RFQ, were reanalyzed by fitting to the 3-D nonlinear simulation code IMPACT. All the data in the measured profiles at the wire scanner were used, not just the rms widths. The measured and ...

Energy Citations Database

88
Beam instrumentation for the SSC RFQ
1993-05-01

A detailed description of the SSC RFQ beam instrumentation is presented. Most of the instrumentation is located in the RFQ end walls. The upstream end wall contains a segmented Faraday cup, a segmented aperture and a wire scanner. The down stream end wall contains a segmented aperture and wire scanner. Two current ...

Energy Citations Database

89
Determination of the Accuracy of Wire Position Sensors

An energy spectrometer has been installed in the LEP accelerator to determine the beam energy with a relative accuracy of 10-4. A precisely calibrated bending magnet is flanked by 6 beam position monitors (BPM). The beam energy is determined by measuring the deflection angle of the LEP beams and the integrated bending field. An accuracy of less than 10-6 m ...

E-print Network

90
Extension of a thin-wire algorithm for wires moved laterally within a mesh
1998-11-01

It was shown that the accuracy of results for wires moved laterally from mesh edges can be greatly improved by taking account of the behavior of the field in the vicinity of the wire. Also, the distance to the end of the wire can be adjusted within a cell by using a general second-order difference form for the ...

DOE Information Bridge

91
Accuracy of 3D scanning technologies in a face scanning context
2005-01-01

In this paper, we will review several different 3D scanning devices. We will present a method for empirical accuracy analysis, and apply it to several scanners providing an overview of their technologies. The scanners include both general purpose and face specific scanning devices. We will focus on face scanning technique, although the ...

E-print Network

92
High density harp or wire scanner for particle beam diagnostics
1996-05-21

A diagnostic detector head harp (23) used to detect and characterize high energy particle beams using an array of closely spaced detector wires (21), typically carbon wires, spaced less than 0.1 cm (0.040 inch) connected to a hybrid microcircuit (25) formed on a ceramic substrate (26). A method to fabricate harps (23) to obtain carbon ...

Energy Citations Database

93
High density harp or wire scanner for particle beam diagnostics
1996-05-21

Disclosed is a diagnostic detector head harp used to detect and characterize high energy particle beams using an array of closely spaced detector wires, typically carbon wires, spaced less than 0.1 cm (0.040 inch) connected to a hybrid microcircuit formed on a ceramic substrate. A method to fabricate harps to obtain carbon wire spacing ...

DOEpatents

94
Considerations for Efficient Wire/Surface Modeling.
1978-01-01

The most significant aspects of a moment method surface patch/wire formulation are speed, accuracy, convergence, and versatility. Techniques for improving these parameters are discussed and applied to a solution based on the piecewise sinusoidal reaction ...

National Technical Information Service (NTIS)

95
An Electric Model for a Cable Clamp on a Single Wire Transmission Line.
1977-01-01

This report describes the development of a lumped element model for a grounded cable clamp on a single wire transmission line. With such a model, it will be possible to increase the accuracy of existing single line, internal EMP interaction computer codes...

National Technical Information Service (NTIS)

96
Accuracy of approximate transmission line formulass for overhead wires
1989-11-01

Errors resulting from two approximations of the transmission line parameters of overhead wires are determined. Sunde's simple approximation is found to be more accurate than the Handel function approximation.

Energy Citations Database

97
Evaluation of portable CT scanners for otologic image-guided surgery.
2011-07-21

PURPOSE: Portable CT scanners are beneficial for diagnosis in the intensive care unit, emergency room, and operating room. Portable fixed-base versus translating-base CT systems were evaluated for otologic image-guided surgical (IGS) applications based on geometric accuracy and utility for percutaneous cochlear implantation. METHODS: Five cadaveric skulls ...

PubMed

98
The impacts of scanner modeling parameters for OPC model of sub-40nm memory device
2010-03-01

It is necessary to apply extreme illumination condition on real device as minimum feature size of the device shrinks. As k1 decrease, ultra extreme illumination has to be used. However, in case of using this illumination, CD and process windows dramatically fluctuate as pupil shapes slightly changes. For past several years, Pupil Fit Modeling (PFM) was developed in order to analyze pupil shape ...

NASA Astrophysics Data System (ADS)

99
High-precision GAFCHROMIC EBT film-based absolute clinical dosimetry using a standard flatbed scanner without the use of a scanner non-uniformity correction.
2010-04-17

To report a study of the use of GAFCHROMIC EBT radiochromic film (RCF) digitized with a commercially available flatbed document scanner for accurate and reliable all-purpose two-dimensional (2D) absolute dosimetry within a clinical environment. We used a simplified methodology that yields high-precision dosimetry measurements without significant postirradiation correction. The ...

PubMed

100
Accuracy of commercial 24-hour electrocardiogram analyzers for quantitation of total and repetitive ventricular arrhythmias.
1987-12-01

The accuracy of 2 commercial 24-hour electrocardiogram analyzers was tested for quantitation of ventricular premature complexes (VPCs). Scanner 1 was the Cardiodata Systems Mark III and scanner 2 was the Avionics Trendsetter DCG VII. Twenty-four-hour electrocardiographic recordings from 19 consecutive ambulatory patients with frequent ...

PubMed

First Page Previous Page 1 2 3 4 5 6 7 Next Page Last Page
 
First Page Previous Page 1 2 3 4 5 6 7 Next Page Last Page
 
101
Ultrasonic Calibration Wire Test Phantom
2004-09-24

We designed and built a phantom consisting of vertical wires maintained under tension to be used as an ultrasonic test, calibration, and reconstruction object for the Lawrence Livermore National Laboratory annular array scanner. We provide a description of the phantom, present example data sets, preliminary reconstructions, example metadata, and MATLAB ...

Energy Citations Database

102
LANSCE-R WIRE-SCANNER ANALOG FRONT-END ELECTRONICS
2011-01-01

A new AFE is being developed for the new LANSCE-R wire-scanner systems. The new AFE is implemented in a National Instruments Compact RIO (cRIO) module installed a BiRa 4U BiRIO cRIO chassis specifically designed to accommodate the cRIO crate and all the wire-scanner interface, control and motor-drive electronics. A single AFE module provides interface to ...

DOE Information Bridge

103
Frequency response of a supported thermocouple wire: Effects of ...

Mar 24, 2009 ... thermocouple represents a compromise between accuracy, ruggedness ... gle of the thermocouple response may be attenuated by axial heat ...

NASA Website

104
An Improved Strain Gage Signal Conditioner for Dynamic ...
1990-10-01

... is an increased demand for accuracy and for extended data bandwidth. ... manufacturers using small-diameter, high-resistance thermocouple wire as ...

DTIC Science & Technology

105
Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies

higher accuracy. The increase in accuracy can be used to make touch inter- faces more reliable, to pack accura- cy. The increase in accuracy can be used to make touch inter- faces more reliable, pack up to 3 of the current touch location. Hardware Implementation The Guardian fingerprint scanner in our prototype ...

E-print Network

106
Technical report. An inexpensive densitometric analysis system using a Macintosh computer and a desktop scanner.
1994-06-01

A brief description of the setup of an inexpensive densitometric analysis system is provided. This system uses a software package and scanner that can be obtained for a total of less than $1000 and that can be operated by any Macintosh computer, including a MacPlus. In the event that a scanner is already available, the software itself can be obtained for ...

PubMed

107
Laser scanning measurements on solar cell test pattern NBS-22. Final report, 1 June 1980-30 November 1981
1981-05-01

The NBS laser scanner has been used to make measurements on the solar cell test pattern, NBS-22, to verify the theoretical calculations of Sawyer, Lehovec, and Fedotowski. The photovoltaic response from cells with controlled sheet resistance step changes and breaks in the metallization contact to the cell was measured and compared to the theoretical predictions. Laser ...

Energy Citations Database

108
Conventional wire scanners for TESLA
2000-01-01

this report are shown in the following table: Parameter Symbol Unit Value Center of mass energy E cm GeV 500 Repetition rate f rep Hz 5 Bunches per pulse n b 2820 Pulse length t pulse s 950 Bunch spacing t bunch f bunch ns MHz 337 2.97 Bunch charge n bunch 1/e 2 10 10 Beam width horizontal s h m (cm) 100 (10 Beam width vertical s v m (cm) 10 (10 Table 1: Parameters of TESLA ...

E-print Network

109
Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC[reg] film
2006-12-15

In this study, we present three significant artifacts that have the potential to negatively impact the accuracy and precision of film dosimetry measurements made using GAFCHROMIC[reg] EBT radiochromic film when read out with CCD flatbed scanners. Films were scanned using three commonly employed instruments: a Macbeth TD932 spot densitometer, an Epson ...

Energy Citations Database

110
Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC film.
2006-12-01

In this study, we present three significant artifacts that have the potential to negatively impact the accuracy and precision of film dosimetry measurements made using GAFCHROMIC EBT radiochromic film when read out with CCD flatbed scanners. Films were scanned using three commonly employed instruments: a Macbeth TD932 spot densitometer, an Epson Expression ...

PubMed

111
Impact of scanner signatures on optical proximity correction
2010-03-01

Low pass filtering of mask diffraction orders, in the projection tools used in microelectronics industry, leads to a range of optical proximity effects, OPEs, impacting integrated circuit pattern images. These predictable OPEs can be corrected with various, model-based optical proximity correction methodologies, OPCs , the success of which strongly depends on the completeness of the imaging models ...

NASA Astrophysics Data System (ADS)

112
A method of 3D scene reconstruction with vehicle-borne laser scanner based on monocular visual positioning
2011-06-01

In the process of 3D reconstruction of the target scene with the moving vehicle-borne single-line scanner, a method of monocular visual positioning is used to locate the exact position of the moving scanner. Attitude sensor, camera and the laser scanner are located on the same platform which is installed on the vehicle. Data can be ...

NASA Astrophysics Data System (ADS)

113
Micron-scale laser-wire scanner for the KEK Accelerator Test Facility extraction line
2010-12-01

A laser-wire transverse electron beam size measurement system has been constructed and operated at the Accelerator Test Facility (ATF) extraction line at KEK. The construction of the system is described in detail along with the environment of the ATF related to the laser wire. A special set of electron beam optics was developed to generate an approximately ...

NASA Astrophysics Data System (ADS)

114
High intensity beam profile monitors for the LAMPF primary beam lines
1979-01-01

Two types of beam profile monitors are in use at LAMPF to measure the properties of the 800 MeV, 500 ..mu..A proton beam external to the linac. Both types use secondary electron emission from a wire to produce a current signal proportional to the amount of proton beam that intercepts the wire. The wire scanner ...

DOE Information Bridge

115
Recent advances to NEC (Numerical Electromagnetics Code): Applications and validation
1989-03-03

Capabilities of the antenna modeling code NEC are reviewed and results are presented to illustrate typical applications. Recent developments are discussed that will improve accuracy in modeling electrically small antennas, stepped-radius wires and junctions of tightly coupled wires, and also a new capability for modeling insulated ...

Energy Citations Database

116
Lightning-induced voltage on an overhead wire influenced by a branch line
1997-01-01

The lightning-induced voltage waveform on an overhead wire having a branch is studied based on numerical calculations. The induced voltage is calculated by the method where the tangential component of the electric field to the overhead wire is looked upon as inducing sources. Accuracy of the calculated result is ensured with ...

Energy Citations Database

117
Investigation on Laser Scanners
2004-09-30

The study and purchase of a three-dimensional laser scanner for a number of diverse metrology tasks at SLAC will be covered. Specifications including range, accuracy, scan density, resolution, field of view and more are discussed and the results of field tests and demonstrations by four potential vendors is covered. This will include details on the ...

DOE Information Bridge

118
Determination of density and thickness of finger bones with an iodine 125 profile scanner. Reproducibility and accuracy of different evaluation methods
1974-01-01

The density of compacta and spongiosa of the finger bone is determined from the attenuation coefficients using an I 125 profile scanner. Possible sources of error are critically tested and various methods of evaluation are compared. Finally, the dependence of the bone density and thickness on the age of life is investigated in a larger test sample. (RW/LH)

Energy Citations Database

119
A micro-computer based system for high precision temperature measurement using Platinum RTD's
1982-07-01

A micro-computer controlled system for 10 channel high precision temperature data acquisition has been developed. The temperature sensing elements are Platinum Resistance Thermometer Devices (RTD's). Probe construction, using standard, commercially available RTD elements is described and wiring and switching requirements for the 4-wire resistance ...

NASA Astrophysics Data System (ADS)

120
Stereo Pushbroom Scanner System Digital Photogrammetry System (DPS) and Its Accuracy.
1986-01-01

A digital stereoscanner with three line sensor arrays working on the pushbroom principle and a suitable rigorous compilation process, was designed. It delivers the orientation data of the camera in selectable update points along the flight path of aircraf...

National Technical Information Service (NTIS)

First Page Previous Page 1 2 3 4 5 6 7 Next Page Last Page
 
First Page Previous Page 1 2 3 4 5 6 7 Next Page Last Page
 
121
Sensitivity of Slope Measurements on Parabolic Solar Mirrors to Positioning and Alignment of the Laser Scanner.
1978-01-01

A laser scanning system for measuring the geometric accuracy of parabolic solar concentrators in both laboratory and field situations is being developed. Inaccuracies in positioning and aligning this device with respect to the parabola reference system wi...

National Technical Information Service (NTIS)

122
Gamma ray scanner systems for nondestructive assay of heterogeneous waste barrels.
1997-01-01

Traditional gamma safeguards measurements have usually been performed using a segmented gamma scanning (SGS) system. The accuracy of this technique relies on the assumption that the sample matrix and the activity are both uniform for a segment. Waste barr...

National Technical Information Service (NTIS)

123
Evaluation of Algorithms for Estimating Wheat Acreage from Multispectral Scanner Data.
1976-01-01

The author has identified the following significant results. Fourteen different classification algorithms were tested for their ability to estimate the proportion of wheat in an area. For some algorithms, accuracy of classification in field centers was ob...

National Technical Information Service (NTIS)

124
Calibration Experiments of a Laser Scanner.
2002-01-01

A LADAR is an instrument which can rapidly capture 3-D data of a scene in the form of x, y, z points. The confidence in end products of the applications 3-D models, positioning, derived quantities-depends largely on the accuracy and precision of the laser...

National Technical Information Service (NTIS)

125
CVO Menu - Mount St. Helens Eruption 2004 - LIDAR
2011-08-06

models (DEMs) with vertical accuracy as good as 10 cm. LIDAR equipment, which includes a laser scanner, a Global Positioning System (GPS), and an Inertial Navigation System (INS),...

Science.gov Websites

First Page Previous Page 1 2 3 4 5 6 7 Next Page Last Page