Sample records for accurately measuring behavioral

  1. A randomized trial to identify accurate and cost-effective fidelity measurement methods for cognitive-behavioral therapy: project FACTS study protocol.

    PubMed

    Beidas, Rinad S; Maclean, Johanna Catherine; Fishman, Jessica; Dorsey, Shannon; Schoenwald, Sonja K; Mandell, David S; Shea, Judy A; McLeod, Bryce D; French, Michael T; Hogue, Aaron; Adams, Danielle R; Lieberman, Adina; Becker-Haimes, Emily M; Marcus, Steven C

    2016-09-15

    This randomized trial will compare three methods of assessing fidelity to cognitive-behavioral therapy (CBT) for youth to identify the most accurate and cost-effective method. The three methods include self-report (i.e., therapist completes a self-report measure on the CBT interventions used in session while circumventing some of the typical barriers to self-report), chart-stimulated recall (i.e., therapist reports on the CBT interventions used in session via an interview with a trained rater, and with the chart to assist him/her) and behavioral rehearsal (i.e., therapist demonstrates the CBT interventions used in session via a role-play with a trained rater). Direct observation will be used as the gold-standard comparison for each of the three methods. This trial will recruit 135 therapists in approximately 12 community agencies in the City of Philadelphia. Therapists will be randomized to one of the three conditions. Each therapist will provide data from three unique sessions, for a total of 405 sessions. All sessions will be audio-recorded and coded using the Therapy Process Observational Coding System for Child Psychotherapy-Revised Strategies scale. This will enable comparison of each measurement approach to direct observation of therapist session behavior to determine which most accurately assesses fidelity. Cost data associated with each method will be gathered. To gather stakeholder perspectives of each measurement method, we will use purposive sampling to recruit 12 therapists from each condition (total of 36 therapists) and 12 supervisors to participate in semi-structured qualitative interviews. Results will provide needed information on how to accurately and cost-effectively measure therapist fidelity to CBT for youth, as well as important information about stakeholder perspectives with regard to each measurement method. Findings will inform fidelity measurement practices in future implementation studies as well as in clinical practice. NCT02820623

  2. Accurate Identification of Fear Facial Expressions Predicts Prosocial Behavior

    PubMed Central

    Marsh, Abigail A.; Kozak, Megan N.; Ambady, Nalini

    2009-01-01

    The fear facial expression is a distress cue that is associated with the provision of help and prosocial behavior. Prior psychiatric studies have found deficits in the recognition of this expression by individuals with antisocial tendencies. However, no prior study has shown accuracy for recognition of fear to predict actual prosocial or antisocial behavior in an experimental setting. In 3 studies, the authors tested the prediction that individuals who recognize fear more accurately will behave more prosocially. In Study 1, participants who identified fear more accurately also donated more money and time to a victim in a classic altruism paradigm. In Studies 2 and 3, participants’ ability to identify the fear expression predicted prosocial behavior in a novel task designed to control for confounding variables. In Study 3, accuracy for recognizing fear proved a better predictor of prosocial behavior than gender, mood, or scores on an empathy scale. PMID:17516803

  3. Accurate identification of fear facial expressions predicts prosocial behavior.

    PubMed

    Marsh, Abigail A; Kozak, Megan N; Ambady, Nalini

    2007-05-01

    The fear facial expression is a distress cue that is associated with the provision of help and prosocial behavior. Prior psychiatric studies have found deficits in the recognition of this expression by individuals with antisocial tendencies. However, no prior study has shown accuracy for recognition of fear to predict actual prosocial or antisocial behavior in an experimental setting. In 3 studies, the authors tested the prediction that individuals who recognize fear more accurately will behave more prosocially. In Study 1, participants who identified fear more accurately also donated more money and time to a victim in a classic altruism paradigm. In Studies 2 and 3, participants' ability to identify the fear expression predicted prosocial behavior in a novel task designed to control for confounding variables. In Study 3, accuracy for recognizing fear proved a better predictor of prosocial behavior than gender, mood, or scores on an empathy scale.

  4. 38 CFR 4.46 - Accurate measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate... indispensable in examinations conducted within the Department of Veterans Affairs. Muscle atrophy must also be...

  5. 38 CFR 4.46 - Accurate measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate... indispensable in examinations conducted within the Department of Veterans Affairs. Muscle atrophy must also be...

  6. 38 CFR 4.46 - Accurate measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate... indispensable in examinations conducted within the Department of Veterans Affairs. Muscle atrophy must also be...

  7. 38 CFR 4.46 - Accurate measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate... indispensable in examinations conducted within the Department of Veterans Affairs. Muscle atrophy must also be...

  8. 38 CFR 4.46 - Accurate measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate... indispensable in examinations conducted within the Department of Veterans Affairs. Muscle atrophy must also be...

  9. Issues and Challenges in Sedentary Behavior Measurement

    ERIC Educational Resources Information Center

    Kang, Minsoo; Rowe, David A.

    2015-01-01

    Previous research has shown the negative impact of sedentary behavior on health, including cardiovascular risk factors, chronic disease-related morbidity, and mortality. Accurate measurement of sedentary behavior is thus important to plan effective interventions and to inform public health messages. This article (a) provides an overview of the…

  10. Vision drives accurate approach behavior during prey capture in laboratory mice

    PubMed Central

    Hoy, Jennifer L.; Yavorska, Iryna; Wehr, Michael; Niell, Cristopher M.

    2016-01-01

    Summary The ability to genetically identify and manipulate neural circuits in the mouse is rapidly advancing our understanding of visual processing in the mammalian brain [1,2]. However, studies investigating the circuitry that underlies complex ethologically-relevant visual behaviors in the mouse have been primarily restricted to fear responses [3–5]. Here, we show that a laboratory strain of mouse (Mus musculus, C57BL/6J) robustly pursues, captures and consumes live insect prey, and that vision is necessary for mice to perform the accurate orienting and approach behaviors leading to capture. Specifically, we differentially perturbed visual or auditory input in mice and determined that visual input is required for accurate approach, allowing maintenance of bearing to within 11 degrees of the target on average during pursuit. While mice were able to capture prey without vision, the accuracy of their approaches and capture rate dramatically declined. To better explore the contribution of vision to this behavior, we developed a simple assay that isolated visual cues and simplified analysis of the visually guided approach. Together, our results demonstrate that laboratory mice are capable of exhibiting dynamic and accurate visually-guided approach behaviors, and provide a means to estimate the visual features that drive behavior within an ethological context. PMID:27773567

  11. Highly accurate surface maps from profilometer measurements

    NASA Astrophysics Data System (ADS)

    Medicus, Kate M.; Nelson, Jessica D.; Mandina, Mike P.

    2013-04-01

    Many aspheres and free-form optical surfaces are measured using a single line trace profilometer which is limiting because accurate 3D corrections are not possible with the single trace. We show a method to produce an accurate fully 2.5D surface height map when measuring a surface with a profilometer using only 6 traces and without expensive hardware. The 6 traces are taken at varying angular positions of the lens, rotating the part between each trace. The output height map contains low form error only, the first 36 Zernikes. The accuracy of the height map is ±10% of the actual Zernike values and within ±3% of the actual peak to valley number. The calculated Zernike values are affected by errors in the angular positioning, by the centering of the lens, and to a small effect, choices made in the processing algorithm. We have found that the angular positioning of the part should be better than 1?, which is achievable with typical hardware. The centering of the lens is essential to achieving accurate measurements. The part must be centered to within 0.5% of the diameter to achieve accurate results. This value is achievable with care, with an indicator, but the part must be edged to a clean diameter.

  12. The potential for accurately measuring behavioral and economic dimensions of consumption, prices, and markets for illegal drugs.

    PubMed

    Johnson, Bruce D; Golub, Andrew

    2007-09-01

    There are numerous analytic and methodological limitations to current measures of drug market activity. This paper explores the structure of markets and individual user behavior to provide an integrated understanding of behavioral and economic (and market) aspects of illegal drug use with an aim toward developing improved procedures for measurement. This involves understanding the social processes that structure illegal distribution networks and drug users' interactions with them. These networks are where and how social behaviors, prices, and markets for illegal drugs intersect. Our focus is upon getting an up close measurement of these activities. Building better measures of consumption behaviors necessitates building better rapport with subjects than typically achieved with one-time surveys in order to overcome withholding and underreporting and to get a comprehensive understanding of the processes involved. This can be achieved through repeated interviews and observations of behaviors. This paper also describes analytic advances that could be adopted to direct this inquiry including behavioral templates, and insights into the economic valuation of labor inputs and cash expenditures for various illegal drugs. Additionally, the paper makes recommendations to funding organizations for developing the mechanisms that would support behavioral scientists to weigh specimens and to collect small samples for laboratory analysis-by providing protection from the potential for arrest. The primary focus is upon U.S. markets. The implications for other countries are discussed.

  13. The Potential for Accurately Measuring Behavioral and Economic Dimensions of Consumption, Prices, and Markets for Illegal Drugs

    PubMed Central

    Johnson, Bruce D.; Golub, Andrew

    2007-01-01

    There are numerous analytic and methodological limitations to current measures of drug market activity. This paper explores the structure of markets and individual user behavior to provide an integrated understanding of behavioral and economic (and market) aspects of illegal drug use with an aim toward developing improved procedures for measurement. This involves understanding the social processes that structure illegal distribution networks and drug users’ interactions with them. These networks are where and how social behaviors, prices, and markets for illegal drugs intersect. Our focus is upon getting an up close measurement of these activities. Building better measures of consumption behaviors necessitates building better rapport with subjects than typically achieved with one-time surveys in order to overcome withholding and underreporting and to get a comprehensive understanding of the processes involved. This can be achieved through repeated interviews and observations of behaviors. This paper also describes analytic advances that could be adopted to direct this inquiry including behavioral templates, and insights into the economic valuation of labor inputs and cash expenditures for various illegal drugs. Additionally, the paper makes recommendations to funding organizations for developing the mechanisms that would support behavioral scientists to weigh specimens and to collect small samples for laboratory analysis—by providing protection from the potential for arrest. The primary focus is upon U.S. markets. The implications for other countries are discussed. PMID:16978801

  14. Highly accurate thickness measurement of multi-layered automotive paints using terahertz technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krimi, Soufiene; Beigang, René; Klier, Jens

    2016-07-11

    In this contribution, we present a highly accurate approach for thickness measurements of multi-layered automotive paints using terahertz time domain spectroscopy in reflection geometry. The proposed method combines the benefits of a model-based material parameters extraction method to calibrate the paint coatings, a generalized Rouard's method to simulate the terahertz radiation behavior within arbitrary thin films, and the robustness of a powerful evolutionary optimization algorithm to increase the sensitivity of the minimum thickness measurement limit. Within the framework of this work, a self-calibration model is introduced, which takes into consideration the real industrial challenges such as the effect of wet-on-wetmore » spray in the painting process.« less

  15. Accurately measuring volcanic plume velocity with multiple UV spectrometers

    USGS Publications Warehouse

    Williams-Jones, Glyn; Horton, Keith A.; Elias, Tamar; Garbeil, Harold; Mouginis-Mark, Peter J; Sutton, A. Jeff; Harris, Andrew J. L.

    2006-01-01

    A fundamental problem with all ground-based remotely sensed measurements of volcanic gas flux is the difficulty in accurately measuring the velocity of the gas plume. Since a representative wind speed and direction are used as proxies for the actual plume velocity, there can be considerable uncertainty in reported gas flux values. Here we present a method that uses at least two time-synchronized simultaneously recording UV spectrometers (FLYSPECs) placed a known distance apart. By analyzing the time varying structure of SO2 concentration signals at each instrument, the plume velocity can accurately be determined. Experiments were conducted on Kīlauea (USA) and Masaya (Nicaragua) volcanoes in March and August 2003 at plume velocities between 1 and 10 m s−1. Concurrent ground-based anemometer measurements differed from FLYSPEC-measured plume speeds by up to 320%. This multi-spectrometer method allows for the accurate remote measurement of plume velocity and can therefore greatly improve the precision of volcanic or industrial gas flux measurements.

  16. Measuring the value of accurate link prediction for network seeding.

    PubMed

    Wei, Yijin; Spencer, Gwen

    2017-01-01

    The influence-maximization literature seeks small sets of individuals whose structural placement in the social network can drive large cascades of behavior. Optimization efforts to find the best seed set often assume perfect knowledge of the network topology. Unfortunately, social network links are rarely known in an exact way. When do seeding strategies based on less-than-accurate link prediction provide valuable insight? We introduce optimized-against-a-sample ([Formula: see text]) performance to measure the value of optimizing seeding based on a noisy observation of a network. Our computational study investigates [Formula: see text] under several threshold-spread models in synthetic and real-world networks. Our focus is on measuring the value of imprecise link information. The level of investment in link prediction that is strategic appears to depend closely on spread model: in some parameter ranges investments in improving link prediction can pay substantial premiums in cascade size. For other ranges, such investments would be wasted. Several trends were remarkably consistent across topologies.

  17. Accurate mass measurement: terminology and treatment of data.

    PubMed

    Brenton, A Gareth; Godfrey, A Ruth

    2010-11-01

    High-resolution mass spectrometry has become ever more accessible with improvements in instrumentation, such as modern FT-ICR and Orbitrap mass spectrometers. This has resulted in an increase in the number of articles submitted for publication quoting accurate mass data. There is a plethora of terms related to accurate mass analysis that are in current usage, many employed incorrectly or inconsistently. This article is based on a set of notes prepared by the authors for research students and staff in our laboratories as a guide to the correct terminology and basic statistical procedures to apply in relation to mass measurement, particularly for accurate mass measurement. It elaborates on the editorial by Gross in 1994 regarding the use of accurate masses for structure confirmation. We have presented and defined the main terms in use with reference to the International Union of Pure and Applied Chemistry (IUPAC) recommendations for nomenclature and symbolism for mass spectrometry. The correct use of statistics and treatment of data is illustrated as a guide to new and existing mass spectrometry users with a series of examples as well as statistical methods to compare different experimental methods and datasets. Copyright © 2010. Published by Elsevier Inc.

  18. Accurately measuring the height of (real) forest trees

    Treesearch

    Don C. Bragg

    2014-01-01

    Quick and accurate tree height measurement has always been a goal of foresters. The techniques and technology to measure height were developed long ago—even the earliest textbooks on mensuration showcased hypsometers (e.g., Schlich 1895, Mlodziansky 1898, Schenck 1905, Graves 1906), and approaches to refine these sometimes remarkable tools appeared in the first issues...

  19. Monitoring circuit accurately measures movement of solenoid valve

    NASA Technical Reports Server (NTRS)

    Gillett, J. D.

    1966-01-01

    Solenoid operated valve in a control system powered by direct current issued to accurately measure the valve travel. This system is currently in operation with a 28-vdc power system used for control of fluids in liquid rocket motor test facilities.

  20. Apparatus for accurately measuring high temperatures

    DOEpatents

    Smith, D.D.

    The present invention is a thermometer used for measuring furnace temperatures in the range of about 1800/sup 0/ to 2700/sup 0/C. The thermometer comprises a broadband multicolor thermal radiation sensor positioned to be in optical alignment with the end of a blackbody sight tube extending into the furnace. A valve-shutter arrangement is positioned between the radiation sensor and the sight tube and a chamber for containing a charge of high pressure gas is positioned between the valve-shutter arrangement and the radiation sensor. A momentary opening of the valve shutter arrangement allows a pulse of the high gas to purge the sight tube of air-borne thermal radiation contaminants which permits the radiation sensor to accurately measure the thermal radiation emanating from the end of the sight tube.

  1. Apparatus for accurately measuring high temperatures

    DOEpatents

    Smith, Douglas D.

    1985-01-01

    The present invention is a thermometer used for measuring furnace temperaes in the range of about 1800.degree. to 2700.degree. C. The thermometer comprises a broadband multicolor thermal radiation sensor positioned to be in optical alignment with the end of a blackbody sight tube extending into the furnace. A valve-shutter arrangement is positioned between the radiation sensor and the sight tube and a chamber for containing a charge of high pressure gas is positioned between the valve-shutter arrangement and the radiation sensor. A momentary opening of the valve shutter arrangement allows a pulse of the high gas to purge the sight tube of air-borne thermal radiation contaminants which permits the radiation sensor to accurately measure the thermal radiation emanating from the end of the sight tube.

  2. On accurate determination of contact angle

    NASA Technical Reports Server (NTRS)

    Concus, P.; Finn, R.

    1992-01-01

    Methods are proposed that exploit a microgravity environment to obtain highly accurate measurement of contact angle. These methods, which are based on our earlier mathematical results, do not require detailed measurement of a liquid free-surface, as they incorporate discontinuous or nearly-discontinuous behavior of the liquid bulk in certain container geometries. Physical testing is planned in the forthcoming IML-2 space flight and in related preparatory ground-based experiments.

  3. Accurate Behavioral Simulator of All-Digital Time-Domain Smart Temperature Sensors by Using SIMULINK

    PubMed Central

    Chen, Chun-Chi; Chen, Chao-Lieh; Lin, You-Ting

    2016-01-01

    This study proposes a new behavioral simulator that uses SIMULINK for all-digital CMOS time-domain smart temperature sensors (TDSTSs) for performing rapid and accurate simulations. Inverter-based TDSTSs offer the benefits of low cost and simple structure for temperature-to-digital conversion and have been developed. Typically, electronic design automation tools, such as HSPICE, are used to simulate TDSTSs for performance evaluations. However, such tools require extremely long simulation time and complex procedures to analyze the results and generate figures. In this paper, we organize simple but accurate equations into a temperature-dependent model (TDM) by which the TDSTSs evaluate temperature behavior. Furthermore, temperature-sensing models of a single CMOS NOT gate were devised using HSPICE simulations. Using the TDM and these temperature-sensing models, a novel simulator in SIMULINK environment was developed to substantially accelerate the simulation and simplify the evaluation procedures. Experiments demonstrated that the simulation results of the proposed simulator have favorable agreement with those obtained from HSPICE simulations, showing that the proposed simulator functions successfully. This is the first behavioral simulator addressing the rapid simulation of TDSTSs. PMID:27509507

  4. Progress Toward Accurate Measurements of Power Consumptions of DBD Plasma Actuators

    NASA Technical Reports Server (NTRS)

    Ashpis, David E.; Laun, Matthew C.; Griebeler, Elmer L.

    2012-01-01

    The accurate measurement of power consumption by Dielectric Barrier Discharge (DBD) plasma actuators is a challenge due to the characteristics of the actuator current signal. Micro-discharges generate high-amplitude, high-frequency current spike transients superimposed on a low-amplitude, low-frequency current. We have used a high-speed digital oscilloscope to measure the actuator power consumption using the Shunt Resistor method and the Monitor Capacitor method. The measurements were performed simultaneously and compared to each other in a time-accurate manner. It was found that low signal-to-noise ratios of the oscilloscopes used, in combination with the high dynamic range of the current spikes, make the Shunt Resistor method inaccurate. An innovative, nonlinear signal compression circuit was applied to the actuator current signal and yielded excellent agreement between the two methods. The paper describes the issues and challenges associated with performing accurate power measurements. It provides insights into the two methods including new insight into the Lissajous curve of the Monitor Capacitor method. Extension to a broad range of parameters and further development of the compression hardware will be performed in future work.

  5. An accurate behavioral model for single-photon avalanche diode statistical performance simulation

    NASA Astrophysics Data System (ADS)

    Xu, Yue; Zhao, Tingchen; Li, Ding

    2018-01-01

    An accurate behavioral model is presented to simulate important statistical performance of single-photon avalanche diodes (SPADs), such as dark count and after-pulsing noise. The derived simulation model takes into account all important generation mechanisms of the two kinds of noise. For the first time, thermal agitation, trap-assisted tunneling and band-to-band tunneling mechanisms are simultaneously incorporated in the simulation model to evaluate dark count behavior of SPADs fabricated in deep sub-micron CMOS technology. Meanwhile, a complete carrier trapping and de-trapping process is considered in afterpulsing model and a simple analytical expression is derived to estimate after-pulsing probability. In particular, the key model parameters of avalanche triggering probability and electric field dependence of excess bias voltage are extracted from Geiger-mode TCAD simulation and this behavioral simulation model doesn't include any empirical parameters. The developed SPAD model is implemented in Verilog-A behavioral hardware description language and successfully operated on commercial Cadence Spectre simulator, showing good universality and compatibility. The model simulation results are in a good accordance with the test data, validating high simulation accuracy.

  6. Measurement of radial artery contrast intensity to assess cardiac microbubble behavior.

    PubMed

    Sosnovik, David E; Januzzi, James L; Church, Charles C; Mertsch, Judith A; Sears, Andrea L; Fetterman, Robert C; Walovitch, Richard C; Picard, Michael H

    2003-12-01

    We sought to determine whether analysis of the contrast signal from the radial artery is better able to reflect changes in left ventricular (LV) microbubble dynamics than the signal from the LV itself. Assessment of microbubble behavior from images of the LV may be affected by attenuation from overlying microbubbles and nonuniform background signal intensities. The signal intensity from contrast in a peripheral artery is not affected by these artifacts and may, thus, be more accurate. After injection of a contrast bolus into a peripheral vein, signal intensity was followed simultaneously in the LV and radial artery. The measurements were repeated using continuous, triggered, low and high mechanical index harmonic imaging of the LV. Peak and integrated signal intensities ranged from 25 dB and 1550 dB/s, respectively, with radial artery imaging to 5.6 dB and 471 dB/s with ventricular imaging. Although differences in microbubble behavior during the different imaging protocols could be determined from both the LV and radial artery curves, analysis of the radial artery curves yielded more consistent and robust differences. The signal from microbubbles in the radial artery is not affected by shadowing and is, thus, a more accurate reflection of microbubble behavior in the LV than the signal from the LV itself. This may have important implications for the measurement of myocardial perfusion by contrast echocardiography.

  7. Accurate Measurements of the Local Deuterium Abundance from HST Spectra

    NASA Technical Reports Server (NTRS)

    Linsky, Jeffrey L.

    1996-01-01

    An accurate measurement of the primordial value of D/H would provide a critical test of nucleosynthesis models for the early universe and the baryon density. I briefly summarize the ongoing HST observations of the interstellar H and D Lyman-alpha absorption for lines of sight to nearby stars and comment on recent reports of extragalactic D/H measurements.

  8. MASS MEASUREMENTS BY AN ACCURATE AND SENSITIVE SELECTED ION RECORDING TECHNIQUE

    EPA Science Inventory

    Trace-level components of mixtures were successfully identified or confirmed by mass spectrometric accurate mass measurements, made at high resolution with selected ion recording, using GC and LC sample introduction. Measurements were made at 20 000 or 10 000 resolution, respecti...

  9. The Psychometric Properties of a New Measure of Sensory Behaviors in Autistic Children

    ERIC Educational Resources Information Center

    Neil, Louise; Green, Dido; Pellicano, Elizabeth

    2017-01-01

    Unusual reactions to sensory input became part of the diagnostic criteria for autism spectrum disorder in the DSM-5. Measures accurately assessing these symptoms are important for clinical decisions. This study examined the reliability and validity of the Sensory Behavior Questionnaire, a parent-report scale designed to assess frequency and impact…

  10. Reliable and accurate extraction of Hamaker constants from surface force measurements.

    PubMed

    Miklavcic, S J

    2018-08-15

    A simple and accurate closed-form expression for the Hamaker constant that best represents experimental surface force data is presented. Numerical comparisons are made with the current standard least squares approach, which falsely assumes error-free separation measurements, and a nonlinear version assuming independent measurements of force and separation are subject to error. The comparisons demonstrate that not only is the proposed formula easily implemented it is also considerably more accurate. This option is appropriate for any value of Hamaker constant, high or low, and certainly for any interacting system exhibiting an inverse square distance dependent van der Waals force. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. A Simple and Accurate Method for Measuring Enzyme Activity.

    ERIC Educational Resources Information Center

    Yip, Din-Yan

    1997-01-01

    Presents methods commonly used for investigating enzyme activity using catalase and presents a new method for measuring catalase activity that is more reliable and accurate. Provides results that are readily reproduced and quantified. Can also be used for investigations of enzyme properties such as the effects of temperature, pH, inhibitors,…

  12. Device accurately measures and records low gas-flow rates

    NASA Technical Reports Server (NTRS)

    Branum, L. W.

    1966-01-01

    Free-floating piston in a vertical column accurately measures and records low gas-flow rates. The system may be calibrated, using an adjustable flow-rate gas supply, a low pressure gage, and a sequence recorder. From the calibration rates, a nomograph may be made for easy reduction. Temperature correction may be added for further accuracy.

  13. Toward more accurate loss tangent measurements in reentrant cavities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moyer, R. D.

    1980-05-01

    Karpova has described an absolute method for measurement of dielectric properties of a solid in a coaxial reentrant cavity. His cavity resonance equation yields very accurate results for dielectric constants. However, he presented only approximate expressions for the loss tangent. This report presents more exact expressions for that quantity and summarizes some experimental results.

  14. Single-Item Measurement of Suicidal Behaviors: Validity and Consequences of Misclassification

    PubMed Central

    Millner, Alexander J.; Lee, Michael D.; Nock, Matthew K.

    2015-01-01

    Suicide is a leading cause of death worldwide. Although research has made strides in better defining suicidal behaviors, there has been less focus on accurate measurement. Currently, the widespread use of self-report, single-item questions to assess suicide ideation, plans and attempts may contribute to measurement problems and misclassification. We examined the validity of single-item measurement and the potential for statistical errors. Over 1,500 participants completed an online survey containing single-item questions regarding a history of suicidal behaviors, followed by questions with more precise language, multiple response options and narrative responses to examine the validity of single-item questions. We also conducted simulations to test whether common statistical tests are robust against the degree of misclassification produced by the use of single-items. We found that 11.3% of participants that endorsed a single-item suicide attempt measure engaged in behavior that would not meet the standard definition of a suicide attempt. Similarly, 8.8% of those who endorsed a single-item measure of suicide ideation endorsed thoughts that would not meet standard definitions of suicide ideation. Statistical simulations revealed that this level of misclassification substantially decreases statistical power and increases the likelihood of false conclusions from statistical tests. Providing a wider range of response options for each item reduced the misclassification rate by approximately half. Overall, the use of single-item, self-report questions to assess the presence of suicidal behaviors leads to misclassification, increasing the likelihood of statistical decision errors. Improving the measurement of suicidal behaviors is critical to increase understanding and prevention of suicide. PMID:26496707

  15. Validity and usability of a safe driving behaviors measure for older adults : strategy for congestion mitigation.

    DOT National Transportation Integrated Search

    2012-01-01

    Statistics project that crash/injury/fatality rates of older drivers will increase with the future growth of : this population. Accurate and precise measurement of older driver behaviors becomes imperative to : curtail these crash trends and resultin...

  16. Consistency of Helping-Behavior Measures.

    ERIC Educational Resources Information Center

    Bar-Tal, Daniel; Raviv, Amiram

    1979-01-01

    Examines the consistency of various methods of measuring helping behavior. Questionnaires concerning helping behavior among 280 sixth graders and teachers' ratings were compared to measures of altruistic behavior and behavioral intention administered 2 years later. (CM)

  17. Feeding Experimentation Device (FED): A flexible open-source device for measuring feeding behavior.

    PubMed

    Nguyen, Katrina P; O'Neal, Timothy J; Bolonduro, Olurotimi A; White, Elecia; Kravitz, Alexxai V

    2016-07-15

    Measuring food intake in rodents is a conceptually simple yet labor-intensive and temporally-imprecise task. Most commonly, food is weighed manually, with an interval of hours or days between measurements. Commercial feeding monitors are excellent, but are costly and require specialized caging and equipment. We have developed the Feeding Experimentation Device (FED): a low-cost, open-source, home cage-compatible feeding system. FED utilizes an Arduino microcontroller and open-source software and hardware. FED dispenses a single food pellet into a food well where it is monitored by an infrared beam. When the mouse removes the pellet, FED logs the timestamp to a secure digital (SD) card and dispenses a new pellet into the well. Post-hoc analyses of pellet retrieval timestamps reveal high-resolution details about feeding behavior. FED is capable of accurately measuring food intake, identifying discrete trends during light and dark-cycle feeding. Additionally, we show the utility of FED for measuring increases in feeding resulting from optogenetic stimulation of agouti-related peptide neurons in the arcuate nucleus of the hypothalamus. With a cost of ∼$350 per device, FED is >10× cheaper than commercially available feeding systems. FED is also self-contained, battery powered, and designed to be placed in standard colony rack cages, allowing for monitoring of true home cage feeding behavior. Moreover, FED is highly adaptable and can be synchronized with emerging techniques in neuroscience, such as optogenetics, as we demonstrate here. FED allows for accurate, precise monitoring of feeding behavior in a home cage setting. Published by Elsevier B.V.

  18. Fast and Accurate Exhaled Breath Ammonia Measurement

    PubMed Central

    Solga, Steven F.; Mudalel, Matthew L.; Spacek, Lisa A.; Risby, Terence H.

    2014-01-01

    This exhaled breath ammonia method uses a fast and highly sensitive spectroscopic method known as quartz enhanced photoacoustic spectroscopy (QEPAS) that uses a quantum cascade based laser. The monitor is coupled to a sampler that measures mouth pressure and carbon dioxide. The system is temperature controlled and specifically designed to address the reactivity of this compound. The sampler provides immediate feedback to the subject and the technician on the quality of the breath effort. Together with the quick response time of the monitor, this system is capable of accurately measuring exhaled breath ammonia representative of deep lung systemic levels. Because the system is easy to use and produces real time results, it has enabled experiments to identify factors that influence measurements. For example, mouth rinse and oral pH reproducibly and significantly affect results and therefore must be controlled. Temperature and mode of breathing are other examples. As our understanding of these factors evolves, error is reduced, and clinical studies become more meaningful. This system is very reliable and individual measurements are inexpensive. The sampler is relatively inexpensive and quite portable, but the monitor is neither. This limits options for some clinical studies and provides rational for future innovations. PMID:24962141

  19. Highly accurate articulated coordinate measuring machine

    DOEpatents

    Bieg, Lothar F.; Jokiel, Jr., Bernhard; Ensz, Mark T.; Watson, Robert D.

    2003-12-30

    Disclosed is a highly accurate articulated coordinate measuring machine, comprising a revolute joint, comprising a circular encoder wheel, having an axis of rotation; a plurality of marks disposed around at least a portion of the circumference of the encoder wheel; bearing means for supporting the encoder wheel, while permitting free rotation of the encoder wheel about the wheel's axis of rotation; and a sensor, rigidly attached to the bearing means, for detecting the motion of at least some of the marks as the encoder wheel rotates; a probe arm, having a proximal end rigidly attached to the encoder wheel, and having a distal end with a probe tip attached thereto; and coordinate processing means, operatively connected to the sensor, for converting the output of the sensor into a set of cylindrical coordinates representing the position of the probe tip relative to a reference cylindrical coordinate system.

  20. Unobtrusive measures in behavioral assessment

    PubMed Central

    Kazdin, Alan E.

    1979-01-01

    A major distinguishing characteristic of behavioral assessment is the direct assessment of overt behavior. Direct assessment is assumed to provide a sample of behavior that reflects client performance in the situation in which behavior is assessed, even if the assessment procedures were not implemented. Yet, in the majority of investigations, behavioral assessment procedures are obtrusive, i.e., subjects are aware that their behavior is being assessed. The potential problem with obtrusive assessment is that it may be reactive, i.e., affect how subjects perform. Recent research has demonstrated that obtrusive observations often are reactive and that behaviors assessed under obtrusive and unobtrusive conditions bear little relation. From methodological and applied perspectives, additional attention needs to be given to unobtrusive measures of behavior change. The present paper illustrates unobtrusive measures in behavior modification including direct observations, archival records, and physical traces of performance. In addition, validation and assessment problems, questions about the obtrusiveness of the measures, and ethical issues are discussed. PMID:16795622

  1. Accurate phase measurements for thick spherical objects using optical quadrature microscopy

    NASA Astrophysics Data System (ADS)

    Warger, William C., II; DiMarzio, Charles A.

    2009-02-01

    In vitro fertilization (IVF) procedures have resulted in the birth of over three million babies since 1978. Yet the live birth rate in the United States was only 34% in 2005, with 32% of the successful pregnancies resulting in multiple births. These multiple pregnancies were directly attributed to the transfer of multiple embryos to increase the probability that a single, healthy embryo was included. Current viability markers used for IVF, such as the cell number, symmetry, size, and fragmentation, are analyzed qualitatively with differential interference contrast (DIC) microscopy. However, this method is not ideal for quantitative measures beyond the 8-cell stage of development because the cells overlap and obstruct the view within and below the cluster of cells. We have developed the phase-subtraction cell-counting method that uses the combination of DIC and optical quadrature microscopy (OQM) to count the number of cells accurately in live mouse embryos beyond the 8-cell stage. We have also created a preliminary analysis to measure the cell symmetry, size, and fragmentation quantitatively by analyzing the relative dry mass from the OQM image in conjunction with the phase-subtraction count. In this paper, we will discuss the characterization of OQM with respect to measuring the phase accurately for spherical samples that are much larger than the depth of field. Once fully characterized and verified with human embryos, this methodology could provide the means for a more accurate method to score embryo viability.

  2. Calibration Techniques for Accurate Measurements by Underwater Camera Systems

    PubMed Central

    Shortis, Mark

    2015-01-01

    Calibration of a camera system is essential to ensure that image measurements result in accurate estimates of locations and dimensions within the object space. In the underwater environment, the calibration must implicitly or explicitly model and compensate for the refractive effects of waterproof housings and the water medium. This paper reviews the different approaches to the calibration of underwater camera systems in theoretical and practical terms. The accuracy, reliability, validation and stability of underwater camera system calibration are also discussed. Samples of results from published reports are provided to demonstrate the range of possible accuracies for the measurements produced by underwater camera systems. PMID:26690172

  3. Accurate Construction of Photoactivated Localization Microscopy (PALM) Images for Quantitative Measurements

    PubMed Central

    Coltharp, Carla; Kessler, Rene P.; Xiao, Jie

    2012-01-01

    Localization-based superresolution microscopy techniques such as Photoactivated Localization Microscopy (PALM) and Stochastic Optical Reconstruction Microscopy (STORM) have allowed investigations of cellular structures with unprecedented optical resolutions. One major obstacle to interpreting superresolution images, however, is the overcounting of molecule numbers caused by fluorophore photoblinking. Using both experimental and simulated images, we determined the effects of photoblinking on the accurate reconstruction of superresolution images and on quantitative measurements of structural dimension and molecule density made from those images. We found that structural dimension and relative density measurements can be made reliably from images that contain photoblinking-related overcounting, but accurate absolute density measurements, and consequently faithful representations of molecule counts and positions in cellular structures, require the application of a clustering algorithm to group localizations that originate from the same molecule. We analyzed how applying a simple algorithm with different clustering thresholds (tThresh and dThresh) affects the accuracy of reconstructed images, and developed an easy method to select optimal thresholds. We also identified an empirical criterion to evaluate whether an imaging condition is appropriate for accurate superresolution image reconstruction with the clustering algorithm. Both the threshold selection method and imaging condition criterion are easy to implement within existing PALM clustering algorithms and experimental conditions. The main advantage of our method is that it generates a superresolution image and molecule position list that faithfully represents molecule counts and positions within a cellular structure, rather than only summarizing structural properties into ensemble parameters. This feature makes it particularly useful for cellular structures of heterogeneous densities and irregular geometries, and

  4. Pelvic orientation for total hip arthroplasty in lateral decubitus: can it be accurately measured?

    PubMed

    Sykes, Alice M; Hill, Janet C; Orr, John F; Gill, Harinderjit S; Salazar, Jose J; Humphreys, Lee D; Beverland, David E

    2016-05-16

    During total hip arthroplasty (THA), accurately predicting acetabular cup orientation remains a key challenge, in great part because of uncertainty about pelvic orientation. This pilot study aimed to develop and validate a technique to measure pelvic orientation; establish its accuracy in the location of anatomical landmarks and subsequently; investigate if limb movement during a simulated surgical procedure alters pelvic orientation. The developed technique measured 3-D orientation of an isolated Sawbone pelvis, it was then implemented to measure pelvic orientation in lateral decubitus with post-THA patients (n = 20) using a motion capture system. Orientation of the isolated Sawbone pelvis was accurately measured, demonstrated by high correlations with angular data from a coordinate measurement machine; R-squared values close to 1 for all pelvic axes. When applied to volunteer subjects, largest movements occurred about the longitudinal pelvic axis; internal and external pelvic rotation. Rotations about the anteroposterior axis, which directly affect inclination angles, showed >75% of participants had movement within ±5° of neutral, 0°. The technique accurately measured orientation of the isolated bony pelvis. This was not the case in a simulated theatre environment. Soft tissue landmarks were difficult to palpate repeatedly. These findings have direct clinical relevance, landmark registration in lateral decubitus is a potential source of error, contributing here to large ranges in measured movement. Surgeons must be aware that present techniques using bony landmarks to reference pelvic orientation for cup implantation, both computer-based and mechanical, may not be sufficiently accurate.

  5. Accurate FRET Measurements within Single Diffusing Biomolecules Using Alternating-Laser Excitation

    PubMed Central

    Lee, Nam Ki; Kapanidis, Achillefs N.; Wang, You; Michalet, Xavier; Mukhopadhyay, Jayanta; Ebright, Richard H.; Weiss, Shimon

    2005-01-01

    Fluorescence resonance energy transfer (FRET) between a donor (D) and an acceptor (A) at the single-molecule level currently provides qualitative information about distance, and quantitative information about kinetics of distance changes. Here, we used the sorting ability of confocal microscopy equipped with alternating-laser excitation (ALEX) to measure accurate FRET efficiencies and distances from single molecules, using corrections that account for cross-talk terms that contaminate the FRET-induced signal, and for differences in the detection efficiency and quantum yield of the probes. ALEX yields accurate FRET independent of instrumental factors, such as excitation intensity or detector alignment. Using DNA fragments, we showed that ALEX-based distances agree well with predictions from a cylindrical model of DNA; ALEX-based distances fit better to theory than distances obtained at the ensemble level. Distance measurements within transcription complexes agreed well with ensemble-FRET measurements, and with structural models based on ensemble-FRET and x-ray crystallography. ALEX can benefit structural analysis of biomolecules, especially when such molecules are inaccessible to conventional structural methods due to heterogeneity or transient nature. PMID:15653725

  6. A spectroscopic transfer standard for accurate atmospheric CO measurements

    NASA Astrophysics Data System (ADS)

    Nwaboh, Javis A.; Li, Gang; Serdyukov, Anton; Werhahn, Olav; Ebert, Volker

    2016-04-01

    Atmospheric carbon monoxide (CO) is a precursor of essential climate variables and has an indirect effect for enhancing global warming. Accurate and reliable measurements of atmospheric CO concentration are becoming indispensable. WMO-GAW reports states a compatibility goal of ±2 ppb for atmospheric CO concentration measurements. Therefore, the EMRP-HIGHGAS (European metrology research program - high-impact greenhouse gases) project aims at developing spectroscopic transfer standards for CO concentration measurements to meet this goal. A spectroscopic transfer standard would provide results that are directly traceable to the SI, can be very useful for calibration of devices operating in the field, and could complement classical gas standards in the field where calibration gas mixtures in bottles often are not accurate, available or stable enough [1][2]. Here, we present our new direct tunable diode laser absorption spectroscopy (dTDLAS) sensor capable of performing absolute ("calibration free") CO concentration measurements, and being operated as a spectroscopic transfer standard. To achieve the compatibility goal stated by WMO for CO concentration measurements and ensure the traceability of the final concentration results, traceable spectral line data especially line intensities with appropriate uncertainties are needed. Therefore, we utilize our new high-resolution Fourier-transform infrared (FTIR) spectroscopy CO line data for the 2-0 band, with significantly reduced uncertainties, for the dTDLAS data evaluation. Further, we demonstrate the capability of our sensor for atmospheric CO measurements, discuss uncertainty calculation following the guide to the expression of uncertainty in measurement (GUM) principles and show that CO concentrations derived using the sensor, based on the TILSAM (traceable infrared laser spectroscopic amount fraction measurement) method, are in excellent agreement with gravimetric values. Acknowledgement Parts of this work have been

  7. Device and method for accurately measuring concentrations of airborne transuranic isotopes

    DOEpatents

    McIsaac, Charles V.; Killian, E. Wayne; Grafwallner, Ervin G.; Kynaston, Ronnie L.; Johnson, Larry O.; Randolph, Peter D.

    1996-01-01

    An alpha continuous air monitor (CAM) with two silicon alpha detectors and three sample collection filters is described. This alpha CAM design provides continuous sampling and also measures the cumulative transuranic (TRU), i.e., plutonium and americium, activity on the filter, and thus provides a more accurate measurement of airborne TRU concentrations than can be accomplished using a single fixed sample collection filter and a single silicon alpha detector.

  8. Device and method for accurately measuring concentrations of airborne transuranic isotopes

    DOEpatents

    McIsaac, C.V.; Killian, E.W.; Grafwallner, E.G.; Kynaston, R.L.; Johnson, L.O.; Randolph, P.D.

    1996-09-03

    An alpha continuous air monitor (CAM) with two silicon alpha detectors and three sample collection filters is described. This alpha CAM design provides continuous sampling and also measures the cumulative transuranic (TRU), i.e., plutonium and americium, activity on the filter, and thus provides a more accurate measurement of airborne TRU concentrations than can be accomplished using a single fixed sample collection filter and a single silicon alpha detector. 7 figs.

  9. Methods to measure olfactory behavior in mice

    PubMed Central

    Zou, Junhui; Wang, Wenbin; Pan, Yung-Wei; Lu, Song; Xia, Zhengui

    2015-01-01

    Mice rely on the sense of olfaction to detect food sources, recognize social and mating partners, and avoid predators. Many behaviors of mice including learning and memory, social interaction, fear, and anxiety are closely associated with their function of olfaction, and behavior tasks designed to evaluate those brain functions may use odors as cues. Accurate assessment of olfaction is not only essential for the study of olfactory system but also critical for proper interpretation of various mouse behaviors especially learning and memory, emotionality and affect, and sociality. Here we describe a series of behavior experiments that offer multidimensional and quantitative assessments for mouse’s olfactory function, including olfactory habituation, discrimination, odor preference, odor detection sensitivity, and olfactory memory, to both social and nonsocial odors. PMID:25645244

  10. An accurate model for predicting high frequency noise of nanoscale NMOS SOI transistors

    NASA Astrophysics Data System (ADS)

    Shen, Yanfei; Cui, Jie; Mohammadi, Saeed

    2017-05-01

    A nonlinear and scalable model suitable for predicting high frequency noise of N-type Metal Oxide Semiconductor (NMOS) transistors is presented. The model is developed for a commercial 45 nm CMOS SOI technology and its accuracy is validated through comparison with measured performance of a microwave low noise amplifier. The model employs the virtual source nonlinear core and adds parasitic elements to accurately simulate the RF behavior of multi-finger NMOS transistors up to 40 GHz. For the first time, the traditional long-channel thermal noise model is supplemented with an injection noise model to accurately represent the noise behavior of these short-channel transistors up to 26 GHz. The developed model is simple and easy to extract, yet very accurate.

  11. Radiometer for accurate (+ or - 1%) measurement of solar irradiance equal to 10,000 solar constants

    NASA Technical Reports Server (NTRS)

    Kendall, J. M., Sr.

    1981-01-01

    The 10,000 solar constant radiometer was developed for the accurate (+ or - 1%) measurement of the irradiance produced in the image formed by a parabolic reflector or by a multiple mirror solar installation. This radiometer is water cooled, weighs about 1 kg, and is 5 cm (2 in.) in diameter by 10 cm (4 in.) long. A sting is provided for mounting the radiometer in the solar installation capable of measuring irradiances as high as 20,000 solar constants, the instrument is self calibrating. Its accuracy depends on the accurate determination of the cavity aperture, and absorptivity of the cavity, and accurate electrical measurements. The spectral response is flat over the entire spectrum from far UV to far IR. The radiometer responds to a measurement within 99.7% of the final value within 8 s. During a measurement of the 10,000 solar constant irradiance, the temperature rise of the water is about 20 C. The radiometer has perfect cosine response up to 60 deg off the radiometer axis.

  12. Multiple-frequency continuous wave ultrasonic system for accurate distance measurement

    NASA Astrophysics Data System (ADS)

    Huang, C. F.; Young, M. S.; Li, Y. C.

    1999-02-01

    A highly accurate multiple-frequency continuous wave ultrasonic range-measuring system for use in air is described. The proposed system uses a method heretofore applied to radio frequency distance measurement but not to air-based ultrasonic systems. The method presented here is based upon the comparative phase shifts generated by three continuous ultrasonic waves of different but closely spaced frequencies. In the test embodiment to confirm concept feasibility, two low cost 40 kHz ultrasonic transducers are set face to face and used to transmit and receive ultrasound. Individual frequencies are transmitted serially, each generating its own phase shift. For any given frequency, the transmitter/receiver distance modulates the phase shift between the transmitted and received signals. Comparison of the phase shifts allows a highly accurate evaluation of target distance. A single-chip microcomputer-based multiple-frequency continuous wave generator and phase detector was designed to record and compute the phase shift information and the resulting distance, which is then sent to either a LCD or a PC. The PC is necessary only for calibration of the system, which can be run independently after calibration. Experiments were conducted to test the performance of the whole system. Experimentally, ranging accuracy was found to be within ±0.05 mm, with a range of over 1.5 m. The main advantages of this ultrasonic range measurement system are high resolution, low cost, narrow bandwidth requirements, and ease of implementation.

  13. Accurate diode behavioral model with reverse recovery

    NASA Astrophysics Data System (ADS)

    Banáš, Stanislav; Divín, Jan; Dobeš, Josef; Paňko, Václav

    2018-01-01

    This paper deals with the comprehensive behavioral model of p-n junction diode containing reverse recovery effect, applicable to all standard SPICE simulators supporting Verilog-A language. The model has been successfully used in several production designs, which require its full complexity, robustness and set of tuning parameters comparable with standard compact SPICE diode model. The model is like standard compact model scalable with area and temperature and can be used as a stand-alone diode or as a part of more complex device macro-model, e.g. LDMOS, JFET, bipolar transistor. The paper briefly presents the state of the art followed by the chapter describing the model development and achieved solutions. During precise model verification some of them were found non-robust or poorly converging and replaced by more robust solutions, demonstrated in the paper. The measurement results of different technologies and different devices compared with a simulation using the new behavioral model are presented as the model validation. The comparison of model validation in time and frequency domains demonstrates that the implemented reverse recovery effect with correctly extracted parameters improves the model simulation results not only in switching from ON to OFF state, which is often published, but also its impedance/admittance frequency dependency in GHz range. Finally the model parameter extraction and the comparison with SPICE compact models containing reverse recovery effect is presented.

  14. Is self-reported height or arm span a more accurate alternative measure of height?

    PubMed

    Brown, Jean K; Feng, Jui-Ying; Knapp, Thomas R

    2002-11-01

    The purpose of this study was to determine whether self-reported height or arm span is the more accurate alternative measure of height. A sample of 409 people between the ages of 19 and 67 (M = 35.0) participated in this anthropometric study. Height, self-reported height, and arm span were measured by 82 nursing research students. Mean differences from criterion measures were 0.17 cm for the measuring rules, 0.47 cm for arm span, and 0.85 cm and 0.87 cm for heights. Test-retest reliability was r = .997 for both height and arm span. The relationships of height to self-reported height and arm span were r = .97 and .90, respectively. Mean absolute differences were 1.80 cm and 4.29 cm, respectively. These findings support the practice of using self-reported height as an alternative measure of measured height in clinical settings, but arm span is an accurate alternative when neither measured height nor self-reported height is obtainable.

  15. Accurate and reproducible measurements of RhoA activation in small samples of primary cells.

    PubMed

    Nini, Lylia; Dagnino, Lina

    2010-03-01

    Rho GTPase activation is essential in a wide variety of cellular processes. Measurement of Rho GTPase activation is difficult with limited material, such as tissues or primary cells that exhibit stringent culture requirements for growth and survival. We defined parameters to accurately and reproducibly measure RhoA activation (i.e., RhoA-GTP) in cultured primary keratinocytes in response to serum and growth factor stimulation using enzyme-linked immunosorbent assay (ELISA)-based G-LISA assays. We also established conditions that minimize RhoA-GTP in unstimulated cells without affecting viability, allowing accurate measurements of RhoA activation on stimulation or induction of exogenous GTPase expression. Copyright 2009 Elsevier Inc. All rights reserved.

  16. Unconstrained and Noninvasive Measurement of Swimming Behavior of Small Fish Based on Ventilatory Signals

    NASA Astrophysics Data System (ADS)

    Kitayama, Shigehisa; Soh, Zu; Hirano, Akira; Tsuji, Toshio; Takiguchi, Noboru; Ohtake, Hisao

    Ventilatory signal is a kind of bioelectric signals reflecting the ventilatory conditions of fish, and has received recent attention as an indicator for assessment of water quality, since breathing is adjusted by the respiratory center according to changes in the underwater environment surrounding the fish. The signals are thus beginning to be used in bioassay systems for water examination. Other than ventilatory conditions, swimming behavior also contains important information for water examination. The conventional bioassay systems, however, only measure either ventilatory signals or swimming behavior. This paper proposes a new unconstrained and noninvasive measurement method that is capable of conducting ventilatory signal measurement and behavioral analysis of fish at the same time. The proposed method estimates the position and the velocity of a fish in free-swimming conditions using power spectrum distribution of measured ventilatory signals from multiple electrodes. This allowed the system to avoid using a camera system which requires light sources. In order to validate estimation accuracy, the position and the velocity estimated by the proposed method were compared to those obtained from video analysis. The results confirmed that the estimated error of the fish positions was within the size of fish, and the correlation coefficient between the velocities was 0.906. The proposed method thus not only can measure the ventilatory signals, but also performs behavioral analysis as accurate as using a video camera.

  17. MEASUREMENT OF BEHAVIORAL THERMOREGULATION

    EPA Science Inventory

    The measurement of thermoregulatory behavior by the techniques of thermal gradient and operant conditioning allows the study of many parameters of the behavioral control of body temperature in particular species as well as the comparative study of thermo- regulatory capabilities ...

  18. Measurement of acute pain in infants: a review of behavioral and physiological variables.

    PubMed

    Hatfield, Linda A; Ely, Elizabeth A

    2015-01-01

    The use of non-validated pain measurement tools to assess infant pain represents a serious iatrogenic threat to the developing neonatal nervous system. One partial explanation for this practice may be the contradictory empirical data from studies that use newborn pain management tools constructed for infants of different developmental stages or exposed to different environmental stressors. The purpose of this review is to evaluate the evidence regarding the physiologic and behavioral variables that accurately assess and measure acute pain response in infants. A literature search was conducted using PUBMED and CINAHL and the search terms infant, neonate/neonatal, newborn, pain, assessment, and measurement to identify peer-reviewed studies that examined the validity and reliability of behavioral and physiological variables used for investigation of infant pain. Ten articles were identified for critical review. Strong evidence supports the use of the behavioral variables of facial expressions and body movements and the physiologic variables of heart rate and oxygen saturation to assess acute pain in infants. It is incumbent upon researchers and clinical nurses to ensure the validity, reliability, and feasibility of pain measures, so that the outcomes of their investigations and interventions will be developmentally appropriate and effective pain management therapies. © The Author(s) 2014.

  19. Neuroscientific Measures of Covert Behavior

    ERIC Educational Resources Information Center

    Ortu, Daniele

    2012-01-01

    In radical behaviorism, the difference between overt and covert responses does not depend on properties of the behavior but on the sensitivity of the measurement tools employed by the experimenter. Current neuroscientific research utilizes technologies that allow measurement of variables that are undetected by the tools typically used by behavior…

  20. An approach for the accurate measurement of social morality levels.

    PubMed

    Liu, Haiyan; Chen, Xia; Zhang, Bo

    2013-01-01

    In the social sciences, computer-based modeling has become an increasingly important tool receiving widespread attention. However, the derivation of the quantitative relationships linking individual moral behavior and social morality levels, so as to provide a useful basis for social policy-making, remains a challenge in the scholarly literature today. A quantitative measurement of morality from the perspective of complexity science constitutes an innovative attempt. Based on the NetLogo platform, this article examines the effect of various factors on social morality levels, using agents modeling moral behavior, immoral behavior, and a range of environmental social resources. Threshold values for the various parameters are obtained through sensitivity analysis; and practical solutions are proposed for reversing declines in social morality levels. The results show that: (1) Population size may accelerate or impede the speed with which immoral behavior comes to determine the overall level of social morality, but it has no effect on the level of social morality itself; (2) The impact of rewards and punishment on social morality levels follows the "5∶1 rewards-to-punishment rule," which is to say that 5 units of rewards have the same effect as 1 unit of punishment; (3) The abundance of public resources is inversely related to the level of social morality; (4) When the cost of population mobility reaches 10% of the total energy level, immoral behavior begins to be suppressed (i.e. the 1/10 moral cost rule). The research approach and methods presented in this paper successfully address the difficulties involved in measuring social morality levels, and promise extensive application potentials.

  1. The Agreement between Parent-Reported and Directly Measured Child Language and Parenting Behaviors

    PubMed Central

    Bennetts, Shannon K.; Mensah, Fiona K.; Westrupp, Elizabeth M.; Hackworth, Naomi J.; Reilly, Sheena

    2016-01-01

    Parenting behaviors are commonly targeted in early interventions to improve children’s language development. Accurate measurement of both parenting behaviors and children’s language outcomes is thus crucial for sensitive assessment of intervention outcomes. To date, only a small number of studies have compared parent-reported and directly measured behaviors, and these have been hampered by small sample sizes and inaccurate statistical techniques, such as correlations. The Bland–Altman Method and Reduced Major Axis regression represent more reliable alternatives because they allow us to quantify fixed and proportional bias between measures. In this study, we draw on data from two Australian early childhood cohorts (N = 201 parents and slow-to-talk toddlers aged 24 months; and N = 218 parents and children aged 6–36 months experiencing social adversity) to (1) examine agreement and quantify bias between parent-reported and direct measures, and (2) to determine socio-demographic predictors of the differences between parent-reported and direct measures. Measures of child language and parenting behaviors were collected from parents and their children. Our findings support the utility of the Bland–Altman Method and Reduced Major Axis regression in comparing measurement methods. Results indicated stronger agreement between parent-reported and directly measured child language, and poorer agreement between measures of parenting behaviors. Child age was associated with difference scores for child language; however, the direction varied for each cohort. Parents who rated their child’s temperament as more difficult tended to report lower language scores on the parent questionnaire, compared to the directly measured scores. Older parents tended to report lower parenting responsiveness on the parent questionnaire, compared to directly measured scores. Finally, speaking a language other than English was associated with less responsive parenting behaviors on the

  2. An Approach for the Accurate Measurement of Social Morality Levels

    PubMed Central

    Liu, Haiyan; Chen, Xia; Zhang, Bo

    2013-01-01

    In the social sciences, computer-based modeling has become an increasingly important tool receiving widespread attention. However, the derivation of the quantitative relationships linking individual moral behavior and social morality levels, so as to provide a useful basis for social policy-making, remains a challenge in the scholarly literature today. A quantitative measurement of morality from the perspective of complexity science constitutes an innovative attempt. Based on the NetLogo platform, this article examines the effect of various factors on social morality levels, using agents modeling moral behavior, immoral behavior, and a range of environmental social resources. Threshold values for the various parameters are obtained through sensitivity analysis; and practical solutions are proposed for reversing declines in social morality levels. The results show that: (1) Population size may accelerate or impede the speed with which immoral behavior comes to determine the overall level of social morality, but it has no effect on the level of social morality itself; (2) The impact of rewards and punishment on social morality levels follows the “5∶1 rewards-to-punishment rule,” which is to say that 5 units of rewards have the same effect as 1 unit of punishment; (3) The abundance of public resources is inversely related to the level of social morality; (4) When the cost of population mobility reaches 10% of the total energy level, immoral behavior begins to be suppressed (i.e. the 1/10 moral cost rule). The research approach and methods presented in this paper successfully address the difficulties involved in measuring social morality levels, and promise extensive application potentials. PMID:24312189

  3. Accurate fluid force measurement based on control surface integration

    NASA Astrophysics Data System (ADS)

    Lentink, David

    2018-01-01

    Nonintrusive 3D fluid force measurements are still challenging to conduct accurately for freely moving animals, vehicles, and deforming objects. Two techniques, 3D particle image velocimetry (PIV) and a new technique, the aerodynamic force platform (AFP), address this. Both rely on the control volume integral for momentum; whereas PIV requires numerical integration of flow fields, the AFP performs the integration mechanically based on rigid walls that form the control surface. The accuracy of both PIV and AFP measurements based on the control surface integration is thought to hinge on determining the unsteady body force associated with the acceleration of the volume of displaced fluid. Here, I introduce a set of non-dimensional error ratios to show which fluid and body parameters make the error negligible. The unsteady body force is insignificant in all conditions where the average density of the body is much greater than the density of the fluid, e.g., in gas. Whenever a strongly deforming body experiences significant buoyancy and acceleration, the error is significant. Remarkably, this error can be entirely corrected for with an exact factor provided that the body has a sufficiently homogenous density or acceleration distribution, which is common in liquids. The correction factor for omitting the unsteady body force, {{{ {ρ f}} {1 - {ρ f} ( {{ρ b}+{ρ f}} )}.{( {{{{ρ }}b}+{ρ f}} )}}} , depends only on the fluid, {ρ f}, and body, {{ρ }}b, density. Whereas these straightforward solutions work even at the liquid-gas interface in a significant number of cases, they do not work for generalized bodies undergoing buoyancy in combination with appreciable body density inhomogeneity, volume change (PIV), or volume rate-of-change (PIV and AFP). In these less common cases, the 3D body shape needs to be measured and resolved in time and space to estimate the unsteady body force. The analysis shows that accounting for the unsteady body force is straightforward to non

  4. Automated measurement of mouse social behaviors using depth sensing, video tracking, and machine learning.

    PubMed

    Hong, Weizhe; Kennedy, Ann; Burgos-Artizzu, Xavier P; Zelikowsky, Moriel; Navonne, Santiago G; Perona, Pietro; Anderson, David J

    2015-09-22

    A lack of automated, quantitative, and accurate assessment of social behaviors in mammalian animal models has limited progress toward understanding mechanisms underlying social interactions and their disorders such as autism. Here we present a new integrated hardware and software system that combines video tracking, depth sensing, and machine learning for automatic detection and quantification of social behaviors involving close and dynamic interactions between two mice of different coat colors in their home cage. We designed a hardware setup that integrates traditional video cameras with a depth camera, developed computer vision tools to extract the body "pose" of individual animals in a social context, and used a supervised learning algorithm to classify several well-described social behaviors. We validated the robustness of the automated classifiers in various experimental settings and used them to examine how genetic background, such as that of Black and Tan Brachyury (BTBR) mice (a previously reported autism model), influences social behavior. Our integrated approach allows for rapid, automated measurement of social behaviors across diverse experimental designs and also affords the ability to develop new, objective behavioral metrics.

  5. Automated measurement of mouse social behaviors using depth sensing, video tracking, and machine learning

    PubMed Central

    Hong, Weizhe; Kennedy, Ann; Burgos-Artizzu, Xavier P.; Zelikowsky, Moriel; Navonne, Santiago G.; Perona, Pietro; Anderson, David J.

    2015-01-01

    A lack of automated, quantitative, and accurate assessment of social behaviors in mammalian animal models has limited progress toward understanding mechanisms underlying social interactions and their disorders such as autism. Here we present a new integrated hardware and software system that combines video tracking, depth sensing, and machine learning for automatic detection and quantification of social behaviors involving close and dynamic interactions between two mice of different coat colors in their home cage. We designed a hardware setup that integrates traditional video cameras with a depth camera, developed computer vision tools to extract the body “pose” of individual animals in a social context, and used a supervised learning algorithm to classify several well-described social behaviors. We validated the robustness of the automated classifiers in various experimental settings and used them to examine how genetic background, such as that of Black and Tan Brachyury (BTBR) mice (a previously reported autism model), influences social behavior. Our integrated approach allows for rapid, automated measurement of social behaviors across diverse experimental designs and also affords the ability to develop new, objective behavioral metrics. PMID:26354123

  6. Accurate potential drop sheet resistance measurements of laser-doped areas in semiconductors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heinrich, Martin, E-mail: mh.seris@gmail.com; NUS Graduate School for Integrative Science and Engineering, National University of Singapore, Singapore 117456; Kluska, Sven

    2014-10-07

    It is investigated how potential drop sheet resistance measurements of areas formed by laser-assisted doping in crystalline Si wafers are affected by typically occurring experimental factors like sample size, inhomogeneities, surface roughness, or coatings. Measurements are obtained with a collinear four point probe setup and a modified transfer length measurement setup to measure sheet resistances of laser-doped lines. Inhomogeneities in doping depth are observed from scanning electron microscope images and electron beam induced current measurements. It is observed that influences from sample size, inhomogeneities, surface roughness, and coatings can be neglected if certain preconditions are met. Guidelines are given onmore » how to obtain accurate potential drop sheet resistance measurements on laser-doped regions.« less

  7. Accurate mass replacement method for the sediment concentration measurement with a constant volume container

    NASA Astrophysics Data System (ADS)

    Ban, Yunyun; Chen, Tianqin; Yan, Jun; Lei, Tingwu

    2017-04-01

    The measurement of sediment concentration in water is of great importance in soil erosion research and soil and water loss monitoring systems. The traditional weighing method has long been the foundation of all the other measuring methods and instrument calibration. The development of a new method to replace the traditional oven-drying method is of interest in research and practice for the quick and efficient measurement of sediment concentration, especially field measurements. A new method is advanced in this study for accurately measuring the sediment concentration based on the accurate measurement of the mass of the sediment-water mixture in the confined constant volume container (CVC). A sediment-laden water sample is put into the CVC to determine its mass before the CVC is filled with water and weighed again for the total mass of the water and sediments in the container. The known volume of the CVC, the mass of sediment-laden water, and sediment particle density are used to calculate the mass of water, which is replaced by sediments, therefore sediment concentration of the sample is calculated. The influence of water temperature was corrected by measuring water density to determine the temperature of water before measurements were conducted. The CVC was used to eliminate the surface tension effect so as to obtain the accurate volume of water and sediment mixture. Experimental results showed that the method was capable of measuring the sediment concentration from 0.5 up to 1200 kg m-3. A good liner relationship existed between the designed and measured sediment concentrations with all the coefficients of determination greater than 0.999 and the averaged relative error less than 0.2%. All of these seem to indicate that the new method is capable of measuring a full range of sediment concentration above 0.5 kg m-3 to replace the traditional oven-drying method as a standard method for evaluating and calibrating other methods.

  8. Optical Coherence Tomography Accurately Measures Corneal Power Change From Laser Refractive Surgery

    PubMed Central

    McNabb, Ryan P.; Farsiu, Sina; Stinnett, Sandra S.; Izatt, Joseph A.; Kuo, Anthony N.

    2014-01-01

    Purpose To determine the ability of motion corrected optical coherence tomography (OCT) to measure the corneal refractive power change due to laser in situ keratomileusis (LASIK). Design Evaluation of a diagnostic test or technology in a cohort. Subjects 70 eyes from 37 subjects undergoing LASIK were measured preoperatively. 39 eyes from 22 subjects were measured postoperatively and completed the study. Methods Consecutive patients undergoing LASIK at the Duke Eye Center who consented to participate were imaged with Placido-ring topography, Scheimpflug photography and OCT on the day of their surgery. Patients were then reimaged with the same imaging systems at the post-operative month 3 visit. Change in pre- to post-operative corneal refractive power as measured by each of the imaging modalities was compared to the pre- to post-operative change in manifest refraction using t-test with generalized estimating equations. Main Outcome Measures Corneal refractive power change due to LASIK as measured by Placido-ring topography, Scheimpflug Photography, and OCT compared to the manifest refraction change vertexed to the corneal plane. The change in manifest refraction should correspond to the change in the corneal refractive power from LASIK and was considered the reference measurement. Results In 22 returning post-LASIK individuals (39 eyes), we found no significant difference between the clinically measured pre to post LASIK change in manifest refraction and both Scheimpflug photography (p = 0.714) and OCT (p = 0.216). In contrast, keratometry values from Placido-ring topography were found to be significantly different from the measured refractive change (p < 0.001). Additionally, of the three imaging modalities, OCT recorded the smallest mean absolute difference from the reference measurement with the least amount of variability. Conclusion Motion corrected OCT more accurately measures the change in corneal refractive power due to laser refractive surgery than

  9. Importance of accurate measurements in nutrition research: dietary flavonoids as a case study

    USDA-ARS?s Scientific Manuscript database

    Accurate measurements of the secondary metabolites in natural products and plant foods are critical to establishing diet/health relationships. There are as many as 50,000 secondary metabolites which may influence human health. Their structural and chemical diversity present a challenge to analytic...

  10. Accurate mass measurement by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry. II. Measurement of negative radical ions using porphyrin and fullerene standard reference materials.

    PubMed

    Shao, Zhecheng; Wyatt, Mark F; Stein, Bridget K; Brenton, A Gareth

    2010-10-30

    A method for the accurate mass measurement of negative radical ions by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) is described. This is an extension to our previously described method for the accurate mass measurement of positive radical ions (Griffiths NW, Wyatt MF, Kean SD, Graham AE, Stein BK, Brenton AG. Rapid Commun. Mass Spectrom. 2010; 24: 1629). The porphyrin standard reference materials (SRMs) developed for positive mode measurements cannot be observed in negative ion mode, so fullerene and fluorinated porphyrin compounds were identified as effective SRMs. The method is of immediate practical use for the accurate mass measurement of functionalised fullerenes, for which negative ion MALDI-TOFMS is the principal mass spectrometry characterisation technique. This was demonstrated by the accurate mass measurement of six functionalised C(60) compounds. Copyright © 2010 John Wiley & Sons, Ltd.

  11. Radio Astronomers Set New Standard for Accurate Cosmic Distance Measurement

    NASA Astrophysics Data System (ADS)

    1999-06-01

    A team of radio astronomers has used the National Science Foundation's Very Long Baseline Array (VLBA) to make the most accurate measurement ever made of the distance to a faraway galaxy. Their direct measurement calls into question the precision of distance determinations made by other techniques, including those announced last week by a team using the Hubble Space Telescope. The radio astronomers measured a distance of 23.5 million light-years to a galaxy called NGC 4258 in Ursa Major. "Ours is a direct measurement, using geometry, and is independent of all other methods of determining cosmic distances," said Jim Herrnstein, of the National Radio Astronomy Observatory (NRAO) in Socorro, NM. The team says their measurement is accurate to within less than a million light-years, or four percent. The galaxy is also known as Messier 106 and is visible with amateur telescopes. Herrnstein, along with James Moran and Lincoln Greenhill of the Harvard- Smithsonian Center for Astrophysics; Phillip Diamond, of the Merlin radio telescope facility at Jodrell Bank and the University of Manchester in England; Makato Inoue and Naomasa Nakai of Japan's Nobeyama Radio Observatory; Mikato Miyoshi of Japan's National Astronomical Observatory; Christian Henkel of Germany's Max Planck Institute for Radio Astronomy; and Adam Riess of the University of California at Berkeley, announced their findings at the American Astronomical Society's meeting in Chicago. "This is an incredible achievement to measure the distance to another galaxy with this precision," said Miller Goss, NRAO's Director of VLA/VLBA Operations. "This is the first time such a great distance has been measured this accurately. It took painstaking work on the part of the observing team, and it took a radio telescope the size of the Earth -- the VLBA -- to make it possible," Goss said. "Astronomers have sought to determine the Hubble Constant, the rate of expansion of the universe, for decades. This will in turn lead to an

  12. An Accurate Link Correlation Estimator for Improving Wireless Protocol Performance

    PubMed Central

    Zhao, Zhiwei; Xu, Xianghua; Dong, Wei; Bu, Jiajun

    2015-01-01

    Wireless link correlation has shown significant impact on the performance of various sensor network protocols. Many works have been devoted to exploiting link correlation for protocol improvements. However, the effectiveness of these designs heavily relies on the accuracy of link correlation measurement. In this paper, we investigate state-of-the-art link correlation measurement and analyze the limitations of existing works. We then propose a novel lightweight and accurate link correlation estimation (LACE) approach based on the reasoning of link correlation formation. LACE combines both long-term and short-term link behaviors for link correlation estimation. We implement LACE as a stand-alone interface in TinyOS and incorporate it into both routing and flooding protocols. Simulation and testbed results show that LACE: (1) achieves more accurate and lightweight link correlation measurements than the state-of-the-art work; and (2) greatly improves the performance of protocols exploiting link correlation. PMID:25686314

  13. Accurate reconstruction of hyperspectral images from compressive sensing measurements

    NASA Astrophysics Data System (ADS)

    Greer, John B.; Flake, J. C.

    2013-05-01

    The emerging field of Compressive Sensing (CS) provides a new way to capture data by shifting the heaviest burden of data collection from the sensor to the computer on the user-end. This new means of sensing requires fewer measurements for a given amount of information than traditional sensors. We investigate the efficacy of CS for capturing HyperSpectral Imagery (HSI) remotely. We also introduce a new family of algorithms for constructing HSI from CS measurements with Split Bregman Iteration [Goldstein and Osher,2009]. These algorithms combine spatial Total Variation (TV) with smoothing in the spectral dimension. We examine models for three different CS sensors: the Coded Aperture Snapshot Spectral Imager-Single Disperser (CASSI-SD) [Wagadarikar et al.,2008] and Dual Disperser (CASSI-DD) [Gehm et al.,2007] cameras, and a hypothetical random sensing model closer to CS theory, but not necessarily implementable with existing technology. We simulate the capture of remotely sensed images by applying the sensor forward models to well-known HSI scenes - an AVIRIS image of Cuprite, Nevada and the HYMAP Urban image. To measure accuracy of the CS models, we compare the scenes constructed with our new algorithm to the original AVIRIS and HYMAP cubes. The results demonstrate the possibility of accurately sensing HSI remotely with significantly fewer measurements than standard hyperspectral cameras.

  14. Toward Accurate Measurement of Participation: Rethinking the Conceptualization and Operationalization of Participatory Evaluation

    ERIC Educational Resources Information Center

    Daigneault, Pierre-Marc; Jacob, Steve

    2009-01-01

    While participatory evaluation (PE) constitutes an important trend in the field of evaluation, its ontology has not been systematically analyzed. As a result, the concept of PE is ambiguous and inadequately theorized. Furthermore, no existing instrument accurately measures stakeholder participation. First, this article attempts to overcome these…

  15. Measuring Fisher Information Accurately in Correlated Neural Populations

    PubMed Central

    Kohn, Adam; Pouget, Alexandre

    2015-01-01

    Neural responses are known to be variable. In order to understand how this neural variability constrains behavioral performance, we need to be able to measure the reliability with which a sensory stimulus is encoded in a given population. However, such measures are challenging for two reasons: First, they must take into account noise correlations which can have a large influence on reliability. Second, they need to be as efficient as possible, since the number of trials available in a set of neural recording is usually limited by experimental constraints. Traditionally, cross-validated decoding has been used as a reliability measure, but it only provides a lower bound on reliability and underestimates reliability substantially in small datasets. We show that, if the number of trials per condition is larger than the number of neurons, there is an alternative, direct estimate of reliability which consistently leads to smaller errors and is much faster to compute. The superior performance of the direct estimator is evident both for simulated data and for neuronal population recordings from macaque primary visual cortex. Furthermore we propose generalizations of the direct estimator which measure changes in stimulus encoding across conditions and the impact of correlations on encoding and decoding, typically denoted by Ishuffle and Idiag respectively. PMID:26030735

  16. Accurate measurement of RF exposure from emerging wireless communication systems

    NASA Astrophysics Data System (ADS)

    Letertre, Thierry; Monebhurrun, Vikass; Toffano, Zeno

    2013-04-01

    Isotropic broadband probes or spectrum analyzers (SAs) may be used for the measurement of rapidly varying electromagnetic fields generated by emerging wireless communication systems. In this paper this problematic is investigated by comparing the responses measured by two different isotropic broadband probes typically used to perform electric field (E-field) evaluations. The broadband probes are submitted to signals with variable duty cycles (DC) and crest factors (CF) either with or without Orthogonal Frequency Division Multiplexing (OFDM) modulation but with the same root-mean-square (RMS) power. The two probes do not provide accurate enough results for deterministic signals such as Worldwide Interoperability for Microwave Access (WIMAX) or Long Term Evolution (LTE) as well as for non-deterministic signals such as Wireless Fidelity (WiFi). The legacy measurement protocols should be adapted to cope for the emerging wireless communication technologies based on the OFDM modulation scheme. This is not easily achieved except when the statistics of the RF emission are well known. In this case the measurement errors are shown to be systematic and a correction factor or calibration can be applied to obtain a good approximation of the total RMS power.

  17. Validity of Self-reported Sexual Behavior Among Adolescents: Where Do We Go from Here?

    PubMed

    DiClemente, Ralph J

    2016-01-01

    Adolescents have high rates of sexually transmitted infections (STIs). Adolescents consuming alcohol and using drugs have markedly greater HIV/STI risk and are a priority population for intervention. Accurate measurement of sexual risk behavior is critical for understanding individual's risk for HIV/STI, transmission dynamics of HIV/STI, and evaluating the efficacy of interventions designed reduce HIV/STI risk. However, significant challenges to accurately measuring adolescents' self-reported sexual behavior are well-documented. Recent advances in microbiology, such as the use of less invasive specimen collection for DNA assays, can assist researchers in more accurately measuring adolescents' sexual risk behavior. However, the majority of studies of adolescents' sexual risk rely solely on self-reported behavior; therefore, methods to improve the validity of adolescents' self-reported sexual behavior are needed. In addition, integrating biologic measures to complement self-reported measures are recommended, when appropriate and feasible.

  18. An accurate automated technique for quasi-optics measurement of the microwave diagnostics for fusion plasma

    NASA Astrophysics Data System (ADS)

    Hu, Jianqiang; Liu, Ahdi; Zhou, Chu; Zhang, Xiaohui; Wang, Mingyuan; Zhang, Jin; Feng, Xi; Li, Hong; Xie, Jinlin; Liu, Wandong; Yu, Changxuan

    2017-08-01

    A new integrated technique for fast and accurate measurement of the quasi-optics, especially for the microwave/millimeter wave diagnostic systems of fusion plasma, has been developed. Using the LabVIEW-based comprehensive scanning system, we can realize not only automatic but also fast and accurate measurement, which will help to eliminate the effects of temperature drift and standing wave/multi-reflection. With the Matlab-based asymmetric two-dimensional Gaussian fitting method, all the desired parameters of the microwave beam can be obtained. This technique can be used in the design and testing of microwave diagnostic systems such as reflectometers and the electron cyclotron emission imaging diagnostic systems of the Experimental Advanced Superconducting Tokamak.

  19. Measuring Neurotic Behavior.

    ERIC Educational Resources Information Center

    Blai, Boris, Jr.

    An exploratory study concerned with the measurement of perseveration, or persistence, as a personality variable was based on the work of G.V. Hamilton, an early investigator in the field. Persistently maladaptive behavior was hypothesized to be a chief characteristic of neurosis. An experimental problem-solving situation was designed to…

  20. A Self-Report Measure of Touching Behavior.

    ERIC Educational Resources Information Center

    Schutte, Nicola S.; And Others

    Because touching is an important and often studied construct, and there is need for a valid self-report measure of touching behavior, a measure of touching behaviors was developed. Touching behaviors to be reported were: brief touch on the arm or shoulder, handshake, hug, hand holding, kiss on the cheek, and kiss on the lips. Persons identified as…

  1. Accurate Measurements of the Dielectric Constant of Seawater at L Band

    NASA Technical Reports Server (NTRS)

    Lang, Roger; Zhou, Yiwen; Utku, Cuneyt; Le Vine, David

    2016-01-01

    This paper describes measurements of the dielectric constant of seawater at a frequency of 1.413 GHz, the center of the protected band (i.e., passive use only) used in the measurement of sea surface salinity from space. The objective of the measurements is to accurately determine the complex dielectric constant of seawater as a function of salinity and temperature. A resonant cylindrical microwave cavity in transmission mode has been employed to make the measurements. The measurements are made using standard seawater at salinities of 30, 33, 35, and 38 practical salinity units over a range of temperatures from 0 degree C to 35 degree C in 5 degree C intervals. Repeated measurements have been made at each temperature and salinity. Mean values and standard deviations are then computed. The total error budget indicates that the real and imaginary parts of the dielectric constant have a combined standard uncertainty of about 0.3 over the range of salinities and temperatures considered. The measurements are compared with the dielectric constants obtained from the model functions of Klein and Swift and those of Meissner and Wentz. The biggest differences occur at low and high temperatures.

  2. Accurate respiration measurement using DC-coupled continuous-wave radar sensor for motion-adaptive cancer radiotherapy.

    PubMed

    Gu, Changzhan; Li, Ruijiang; Zhang, Hualiang; Fung, Albert Y C; Torres, Carlos; Jiang, Steve B; Li, Changzhi

    2012-11-01

    Accurate respiration measurement is crucial in motion-adaptive cancer radiotherapy. Conventional methods for respiration measurement are undesirable because they are either invasive to the patient or do not have sufficient accuracy. In addition, measurement of external respiration signal based on conventional approaches requires close patient contact to the physical device which often causes patient discomfort and undesirable motion during radiation dose delivery. In this paper, a dc-coupled continuous-wave radar sensor was presented to provide a noncontact and noninvasive approach for respiration measurement. The radar sensor was designed with dc-coupled adaptive tuning architectures that include RF coarse-tuning and baseband fine-tuning, which allows the radar sensor to precisely measure movement with stationary moment and always work with the maximum dynamic range. The accuracy of respiration measurement with the proposed radar sensor was experimentally evaluated using a physical phantom, human subject, and moving plate in a radiotherapy environment. It was shown that respiration measurement with radar sensor while the radiation beam is on is feasible and the measurement has a submillimeter accuracy when compared with a commercial respiration monitoring system which requires patient contact. The proposed radar sensor provides accurate, noninvasive, and noncontact respiration measurement and therefore has a great potential in motion-adaptive radiotherapy.

  3. Accurate Measurement of the Optical Constants for Organic and Organophosphorous Liquid Layers and Drops

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Myers, Tanya L.; Tonkyn, Russell G.; Danby, Tyler O.

    We present accurate measurements for the determination of the optical constants for a series of organic liquids, including organophosphorous compounds. Bulk liquids are rarely encountered in the environment, but more commonly are present as droplets of liquids or thin layers on various substrates. Providing reference spectra to account for the plethora of morphological conditions that may be encountered under different scenarios is a challenge. An alternative approach is to provide the complex optical constants, n and k, which can be used to model the optical phenomena in media and at interfaces, minimizing the need for a vast number of laboratorymore » measurements. In this work, we present improved protocols for measuring the optical constants for a series of liquids that span the range from 7800 to 400 cm-1. The broad spectral range means that one needs to account for both the strong and weak spectral features that are encountered, all of which can be useful for detection, depending on the scenario. To span this dynamic range, both long and short cells are required for accurate measurements. The protocols are presented along with experimental and modeling results for thin layers of silicone oil on aluminum.« less

  4. Validating Measures of Brinkmanship Behaviors.

    ERIC Educational Resources Information Center

    Melancon, Janet G.; Thompson, Bruce

    This study investigated the validity of measures of teacher brinkmanship behaviors. These are behaviors which challenge the authority system of the school while avoiding its negative sanctions. These acts are generally satirical in nature. The subjects were teachers and principals representing schools located in a metropolitan school system in the…

  5. The preliminary exploration of 64-slice volume computed tomography in the accurate measurement of pleural effusion.

    PubMed

    Guo, Zhi-Jun; Lin, Qiang; Liu, Hai-Tao; Lu, Jun-Ying; Zeng, Yan-Hong; Meng, Fan-Jie; Cao, Bin; Zi, Xue-Rong; Han, Shu-Ming; Zhang, Yu-Huan

    2013-09-01

    Using computed tomography (CT) to rapidly and accurately quantify pleural effusion volume benefits medical and scientific research. However, the precise volume of pleural effusions still involves many challenges and currently does not have a recognized accurate measuring. To explore the feasibility of using 64-slice CT volume-rendering technology to accurately measure pleural fluid volume and to then analyze the correlation between the volume of the free pleural effusion and the different diameters of the pleural effusion. The 64-slice CT volume-rendering technique was used to measure and analyze three parts. First, the fluid volume of a self-made thoracic model was measured and compared with the actual injected volume. Second, the pleural effusion volume was measured before and after pleural fluid drainage in 25 patients, and the volume reduction was compared with the actual volume of the liquid extract. Finally, the free pleural effusion volume was measured in 26 patients to analyze the correlation between it and the diameter of the effusion, which was then used to calculate the regression equation. After using the 64-slice CT volume-rendering technique to measure the fluid volume of the self-made thoracic model, the results were compared with the actual injection volume. No significant differences were found, P = 0.836. For the 25 patients with drained pleural effusions, the comparison of the reduction volume with the actual volume of the liquid extract revealed no significant differences, P = 0.989. The following linear regression equation was used to compare the pleural effusion volume (V) (measured by the CT volume-rendering technique) with the pleural effusion greatest depth (d): V = 158.16 × d - 116.01 (r = 0.91, P = 0.000). The following linear regression was used to compare the volume with the product of the pleural effusion diameters (l × h × d): V = 0.56 × (l × h × d) + 39.44 (r = 0.92, P = 0.000). The 64-slice CT volume-rendering technique can

  6. Accurate acoustic power measurement for low-intensity focused ultrasound using focal axial vibration velocity

    NASA Astrophysics Data System (ADS)

    Tao, Chenyang; Guo, Gepu; Ma, Qingyu; Tu, Juan; Zhang, Dong; Hu, Jimin

    2017-07-01

    Low-intensity focused ultrasound is a form of therapy that can have reversible acoustothermal effects on biological tissue, depending on the exposure parameters. The acoustic power (AP) should be chosen with caution for the sake of safety. To recover the energy of counteracted radial vibrations at the focal point, an accurate AP measurement method using the focal axial vibration velocity (FAVV) is proposed in explicit formulae and is demonstrated experimentally using a laser vibrometer. The experimental APs for two transducers agree well with theoretical calculations and numerical simulations, showing that AP is proportional to the square of the FAVV, with a fixed power gain determined by the physical parameters of the transducers. The favorable results suggest that the FAVV can be used as a valuable parameter for non-contact AP measurement, providing a new strategy for accurate power control for low-intensity focused ultrasound in biomedical engineering.

  7. Precise and accurate isotope ratio measurements by ICP-MS.

    PubMed

    Becker, J S; Dietze, H J

    2000-09-01

    The precise and accurate determination of isotope ratios by inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) is important for quite different application fields (e.g. for isotope ratio measurements of stable isotopes in nature, especially for the investigation of isotope variation in nature or age dating, for determining isotope ratios of radiogenic elements in the nuclear industry, quality assurance of fuel material, for reprocessing plants, nuclear material accounting and radioactive waste control, for tracer experiments using stable isotopes or long-lived radionuclides in biological or medical studies). Thermal ionization mass spectrometry (TIMS), which used to be the dominant analytical technique for precise isotope ratio measurements, is being increasingly replaced for isotope ratio measurements by ICP-MS due to its excellent sensitivity, precision and good accuracy. Instrumental progress in ICP-MS was achieved by the introduction of the collision cell interface in order to dissociate many disturbing argon-based molecular ions, thermalize the ions and neutralize the disturbing argon ions of plasma gas (Ar+). The application of the collision cell in ICP-QMS results in a higher ion transmission, improved sensitivity and better precision of isotope ratio measurements compared to quadrupole ICP-MS without the collision cell [e.g., for 235U/238U approximately 1 (10 microg x L(-1) uranium) 0.07% relative standard deviation (RSD) vs. 0.2% RSD in short-term measurements (n = 5)]. A significant instrumental improvement for ICP-MS is the multicollector device (MC-ICP-MS) in order to obtain a better precision of isotope ratio measurements (with a precision of up to 0.002%, RSD). CE- and HPLC-ICP-MS are used for the separation of isobaric interferences of long-lived radionuclides and stable isotopes by determination of spallation nuclide abundances in an irradiated tantalum target.

  8. A facile electrode preparation method for accurate electrochemical measurements of double-side-coated electrode from commercial Li-ion batteries

    NASA Astrophysics Data System (ADS)

    Zhou, Ge; Wang, Qiyu; Wang, Shuo; Ling, Shigang; Zheng, Jieyun; Yu, Xiqian; Li, Hong

    2018-04-01

    The post mortem electrochemical analysis, including charge-discharge and electrochemical impedance spectroscopy (EIS) measurements, are critical steps for revealing the failure mechanisms of commercial lithium-ion batteries (LIBs). These post measurements usually require the reassembling of coin-cell with electrode which is often double-side-coated in commercial LIBs. It is difficult to use such double-side-coated electrode to perform accurate electrochemical measurements because the back side of the electrode is coated with active materials, rather than single-side-coated electrode that is often used in coin-cell measurements. In this study, we report a facile tape-covering sample preparation method, which can effectively suppress the influence of back side of the double-side-coated electrodes on capacity and EIS measurements in coin-cells. By tape-covering the unwanted side, the areal capacity of the desired investigated side of the electrode has been accurately measured with an experimental error of about 0.5% at various current densities, and accurate EIS measurements and analysis have been conducted as well.

  9. Latest Developments on Obtaining Accurate Measurements with Pitot Tubes in ZPG Turbulent Boundary Layers

    NASA Astrophysics Data System (ADS)

    Nagib, Hassan; Vinuesa, Ricardo

    2013-11-01

    Ability of available Pitot tube corrections to provide accurate mean velocity profiles in ZPG boundary layers is re-examined following the recent work by Bailey et al. Measurements by Bailey et al., carried out with probes of diameters ranging from 0.2 to 1.89 mm, together with new data taken with larger diameters up to 12.82 mm, show deviations with respect to available high-quality datasets and hot-wire measurements in the same Reynolds number range. These deviations are significant in the buffer region around y+ = 30 - 40 , and lead to disagreement in the von Kármán coefficient κ extracted from profiles. New forms for shear, near-wall and turbulence corrections are proposed, highlighting the importance of the latest one. Improved agreement in mean velocity profiles is obtained with new forms, where shear and near-wall corrections contribute with around 85%, and remaining 15% of the total correction comes from turbulence correction. Finally, available algorithms to correct wall position in profile measurements of wall-bounded flows are tested, using as benchmark the corrected Pitot measurements with artificially simulated probe shifts and blockage effects. We develop a new scheme, κB - Musker, which is able to accurately locate wall position.

  10. A Time-Accurate Upwind Unstructured Finite Volume Method for Compressible Flow with Cure of Pathological Behaviors

    NASA Technical Reports Server (NTRS)

    Loh, Ching Y.; Jorgenson, Philip C. E.

    2007-01-01

    A time-accurate, upwind, finite volume method for computing compressible flows on unstructured grids is presented. The method is second order accurate in space and time and yields high resolution in the presence of discontinuities. For efficiency, the Roe approximate Riemann solver with an entropy correction is employed. In the basic Euler/Navier-Stokes scheme, many concepts of high order upwind schemes are adopted: the surface flux integrals are carefully treated, a Cauchy-Kowalewski time-stepping scheme is used in the time-marching stage, and a multidimensional limiter is applied in the reconstruction stage. However even with these up-to-date improvements, the basic upwind scheme is still plagued by the so-called "pathological behaviors," e.g., the carbuncle phenomenon, the expansion shock, etc. A solution to these limitations is presented which uses a very simple dissipation model while still preserving second order accuracy. This scheme is referred to as the enhanced time-accurate upwind (ETAU) scheme in this paper. The unstructured grid capability renders flexibility for use in complex geometry; and the present ETAU Euler/Navier-Stokes scheme is capable of handling a broad spectrum of flow regimes from high supersonic to subsonic at very low Mach number, appropriate for both CFD (computational fluid dynamics) and CAA (computational aeroacoustics). Numerous examples are included to demonstrate the robustness of the methods.

  11. Handcrafted cuff manometers do not accurately measure endotracheal tube cuff pressure

    PubMed Central

    Annoni, Raquel; de Almeida, Antonio Evanir

    2015-01-01

    Objective To test the agreement between two handcrafted devices and a cuff-specific manometer. Methods The agreement between two handcrafted devices adapted to measure tracheal tube cuff pressure and a cuff-specific manometer was tested on 79 subjects. The cuff pressure was measured with a commercial manometer and with two handcrafted devices (HD) assembled with aneroid sphygmomanometers (HD1 and HD2). The data were compared using Wilcoxon and Spearman tests, the intraclass correlation coefficient (ICC) and limit-of-agreement analysis. Results Cuff pressures assessed with handcrafted devices were significantly different from commercial device measurements (pressures were higher when measured with HD1 and lower with HD2). The ICCs between the commercial device and HD1 and HD2 were excellent (ICC = 0.8 p < 0.001) and good (ICC = 0.66, p < 0.001), respectively. However, the Bland- Altman plots showed wide limits of agreement between HD1 and HD2 and the commercial device. Conclusion The handcrafted manometers do not provide accurate cuff pressure measurements when compared to a cuff-specific device and should not be used to replace the commercial cuff manometers in mechanically ventilated patients. PMID:26376160

  12. Accurate Critical Stress Intensity Factor Griffith Crack Theory Measurements by Numerical Techniques

    PubMed Central

    Petersen, Richard C.

    2014-01-01

    Critical stress intensity factor (KIc) has been an approximation for fracture toughness using only load-cell measurements. However, artificial man-made cracks several orders of magnitude longer and wider than natural flaws have required a correction factor term (Y) that can be up to about 3 times the recorded experimental value [1-3]. In fact, over 30 years ago a National Academy of Sciences advisory board stated that empirical KIc testing was of serious concern and further requested that an accurate bulk fracture toughness method be found [4]. Now that fracture toughness can be calculated accurately by numerical integration from the load/deflection curve as resilience, work of fracture (WOF) and strain energy release (SIc) [5, 6], KIc appears to be unnecessary. However, the large body of previous KIc experimental test results found in the literature offer the opportunity for continued meta analysis with other more practical and accurate fracture toughness results using energy methods and numerical integration. Therefore, KIc is derived from the classical Griffith Crack Theory [6] to include SIc as a more accurate term for strain energy release rate (𝒢Ic), along with crack surface energy (γ), crack length (a), modulus (E), applied stress (σ), Y, crack-tip plastic zone defect region (rp) and yield strength (σys) that can all be determined from load and deflection data. Polymer matrix discontinuous quartz fiber-reinforced composites to accentuate toughness differences were prepared for flexural mechanical testing comprising of 3 mm fibers at different volume percentages from 0-54.0 vol% and at 28.2 vol% with different fiber lengths from 0.0-6.0 mm. Results provided a new correction factor and regression analyses between several numerical integration fracture toughness test methods to support KIc results. Further, bulk KIc accurate experimental values are compared with empirical test results found in literature. Also, several fracture toughness mechanisms

  13. Conceptual framework on the application of biomechanical measurement methods in driving behavior study

    NASA Astrophysics Data System (ADS)

    Sanjaya, Kadek Heri; Sya'bana, Yukhi Mustaqim Kusuma

    2017-01-01

    Research on eco-friendly vehicle development in Indonesia has largely neglected ergonomic study, despite the fact that traffic accidents have resulted in greater economic cost than fuel subsidy. We have performed a biomechanical experiment on human locomotion earlier. In this article, we describe the importance of implementing the biomechanical measurement methods in transportation ergonomic study. The instruments such as electromyogram (EMG), load cell, pressure sensor, and motion analysis methods as well as cross-correlation function analysis were explained, then the possibility of their application in driving behavior study is described. We describe the potentials and challenges of the biomechanical methods concerning the future vehicle development. The methods provide greater advantages in objective and accurate measurement not only in human task performance but also its correlation with vehicle performance.

  14. ACCURATE: Greenhouse Gas Profiles Retrieval from Combined IR-Laser and Microwave Occultation Measurements

    NASA Astrophysics Data System (ADS)

    Proschek, Veronika; Kirchengast, Gottfried; Schweitzer, Susanne; Fritzer, Johannes

    2010-05-01

    The new climate satellite concept ACCURATE (Atmospheric Climate and Chemistry in the UTLS Region And climate Trends Explorer) enables simultaneous measurement of profiles of greenhouse gases, isotopes, wind and thermodynamic variables from Low Earth Orbit (LEO) satellites. The measurement principle applied is a combination of the novel LEO-LEO infrared laser occultation (LIO) technique and the already better studied LEO-LEO microwave occultation (LMO) technique. Resulting occultation events are evenly distributed around the world, have high vertical resolution and accuracy and are stable over long time periods. The LIO uses near-monochromatic signals in the short-wave infrared range (~2-2.5 μm for ACCURATE). These signals are absorbed by various trace species in the Earth's atmosphere. Profiles of the concentration of the absorbing species can be derived from signal transmission measurements. Accurately known temperature, pressure and humidity profiles derived from simultaneously measured LMO signals are essential pre-information for the retrieval of the trace species profiles. These LMO signals lie in the microwave band region from 17-23 GHz and, optionally, 178-195 GHz. The current ACCURATE mission design is arranged for the measurement of six greenhouse gases (GHG) (H2O, CO2, CH4, N2O, O3, CO) and four isotopes (13CO2, C18OO, HDO, H218O), with focus on the upper troposphere/lower stratosphere region (UTLS, 5-35 km). Wind speed in line-of-sight can be derived from a line-symmetric transmission difference which is caused by wind-induced Doppler shift. By-products are information on cloud layering, aerosol extinction, and scintillation strength. We introduce the methodology to retrieve GHG profiles from quasi-realistic forward-simulated intensities of LIO signals and thermodynamic profiles retrieved in a preceding step from LMO signals. Key of the retrieval methodology is the differencing of two LIO transmission signals, one being GHG sensitive on a target

  15. Accurate Measurements of the Dielectric Constant of Seawater at L Band

    NASA Technical Reports Server (NTRS)

    Lang, Roger H.; Utku, Cuneyt; Tarkocin, Yalcin; LeVine, David M.

    2010-01-01

    This report describes measurements of the dielectric constant of seawater at a frequency of 1.413 GHz that is at the center of the L-Sand radiometric protected frequency spectrum. Aquarius will be sensing the sea surface salinity from space in this band. The objective of the project is to refine the model function for the dielectric constant as a function of salinity and temperature so that remote sensing measurements can be made with the accuracy needed to meet the measurement goals (0.2 psu) of the Aquarius mission. The measurements were made, using a microwave cavity operated in the transmission configuration. The cavity's temperature was accurately regulated to 0.02 C by immersing it in a temperature controlled bath of distilled water and ethanol glycol. Seawater had been purchased from Ocean Scientific International Limited (OS1L) at salinities of 30, 35 and 38 psu. Measurements of these seawater samples were then made over a range of temperatures, from l0 C to 35 C in 5 C intervals. Repeated measurements were made at each temperature and salinity, Mean values and standard deviations were then computed. Total error budgets indicated that the real and imaginary parts of the dielectric constant had a relative accuracy of about l%.

  16. Geometric optimisation of an accurate cosine correcting optic fibre coupler for solar spectral measurement.

    PubMed

    Cahuantzi, Roberto; Buckley, Alastair

    2017-09-01

    Making accurate and reliable measurements of solar irradiance is important for understanding performance in the photovoltaic energy sector. In this paper, we present design details and performance of a number of fibre optic couplers for use in irradiance measurement systems employing remote light sensors applicable for either spectrally resolved or broadband measurement. The angular and spectral characteristics of different coupler designs are characterised and compared with existing state-of-the-art commercial technology. The new coupler designs are fabricated from polytetrafluorethylene (PTFE) rods and operate through forward scattering of incident sunlight on the front surfaces of the structure into an optic fibre located in a cavity to the rear of the structure. The PTFE couplers exhibit up to 4.8% variation in scattered transmission intensity between 425 nm and 700 nm and show minimal specular reflection, making the designs accurate and reliable over the visible region. Through careful geometric optimization near perfect cosine dependence on the angular response of the coupler can be achieved. The PTFE designs represent a significant improvement over the state of the art with less than 0.01% error compared with ideal cosine response for angles of incidence up to 50°.

  17. Finding the most accurate method to measure head circumference for fetal weight estimation.

    PubMed

    Schmidt, Ulrike; Temerinac, Dunja; Bildstein, Katharina; Tuschy, Benjamin; Mayer, Jade; Sütterlin, Marc; Siemer, Jörn; Kehl, Sven

    2014-07-01

    Accurate measurement of fetal head biometry is important for fetal weight estimation (FWE) and is therefore an important prognostic parameter for neonatal morbidity and mortality and a valuable tool for determining the further obstetric management. Measurement of the head circumference (HC) in particular is employed in many commonly used weight equations. The aim of the present study was to find the most accurate method to measure head circumference for fetal weight estimation. This prospective study included 481 term pregnancies. Inclusion criteria were a singleton pregnancy and ultrasound examination with complete fetal biometric parameters within 3 days of delivery, and an absence of structural or chromosomal malformations. Different methods were used for ultrasound measurement of the HC (ellipse-traced, ellipse-calculated, and circle-calculated). As a reference method, HC was also determined using a measuring tape immediately after birth. FWE was carried out with Hadlock formulas, including either HC or biparietal diameter (BPD), and differences were compared using percentage error (PE), absolute percentage error (APE), limits of agreement (LOA), and cumulative distribution. The ellipse-traced method showed the best results for FWE among all of the ultrasound methods assessed. It had the lowest median APE and the narrowest LOA. With regard to the cumulative distribution, it included the largest number of cases at a discrepancy level of ±10%. The accuracy of BPD was similar to that of the ellipse-traced method when it was used instead of HC for weight estimation. Differences between the three techniques for calculating HC were small but significant. For clinical use, the ellipse-traced method should be recommended. However, when BPD is used instead of HC for FWE, the accuracy is similar to that of the ellipse-traced method. The BPD might therefore be a good alternative to head measurements in estimating fetal weight. Copyright © 2014 Elsevier Ireland Ltd. All

  18. Does a pneumotach accurately characterize voice function?

    NASA Astrophysics Data System (ADS)

    Walters, Gage; Krane, Michael

    2016-11-01

    A study is presented which addresses how a pneumotach might adversely affect clinical measurements of voice function. A pneumotach is a device, typically a mask, worn over the mouth, in order to measure time-varying glottal volume flow. By measuring the time-varying difference in pressure across a known aerodynamic resistance element in the mask, the glottal volume flow waveform is estimated. Because it adds aerodynamic resistance to the vocal system, there is some concern that using a pneumotach may not accurately portray the behavior of the voice. To test this hypothesis, experiments were performed in a simplified airway model with the principal dimensions of an adult human upper airway. A compliant constriction, fabricated from silicone rubber, modeled the vocal folds. Variations of transglottal pressure, time-averaged volume flow, model vocal fold vibration amplitude, and radiated sound with subglottal pressure were performed, with and without the pneumotach in place, and differences noted. Acknowledge support of NIH Grant 2R01DC005642-10A1.

  19. Accurate macromolecular structures using minimal measurements from X-ray free-electron lasers

    PubMed Central

    Hattne, Johan; Echols, Nathaniel; Tran, Rosalie; Kern, Jan; Gildea, Richard J.; Brewster, Aaron S.; Alonso-Mori, Roberto; Glöckner, Carina; Hellmich, Julia; Laksmono, Hartawan; Sierra, Raymond G.; Lassalle-Kaiser, Benedikt; Lampe, Alyssa; Han, Guangye; Gul, Sheraz; DiFiore, Dörte; Milathianaki, Despina; Fry, Alan R.; Miahnahri, Alan; White, William E.; Schafer, Donald W.; Seibert, M. Marvin; Koglin, Jason E.; Sokaras, Dimosthenis; Weng, Tsu-Chien; Sellberg, Jonas; Latimer, Matthew J.; Glatzel, Pieter; Zwart, Petrus H.; Grosse-Kunstleve, Ralf W.; Bogan, Michael J.; Messerschmidt, Marc; Williams, Garth J.; Boutet, Sébastien; Messinger, Johannes; Zouni, Athina; Yano, Junko; Bergmann, Uwe; Yachandra, Vittal K.; Adams, Paul D.; Sauter, Nicholas K.

    2014-01-01

    X-ray free-electron laser (XFEL) sources enable the use of crystallography to solve three-dimensional macromolecular structures under native conditions and free from radiation damage. Results to date, however, have been limited by the challenge of deriving accurate Bragg intensities from a heterogeneous population of microcrystals, while at the same time modeling the X-ray spectrum and detector geometry. Here we present a computational approach designed to extract statistically significant high-resolution signals from fewer diffraction measurements. PMID:24633409

  20. Invited article: Time accurate mass flow measurements of solid-fueled systems.

    PubMed

    Olliges, Jordan D; Lilly, Taylor C; Joslyn, Thomas B; Ketsdever, Andrew D

    2008-10-01

    A novel diagnostic method is described that utilizes a thrust stand mass balance (TSMB) to directly measure time-accurate mass flow from a solid-fuel thruster. The accuracy of the TSMB mass flow measurement technique was demonstrated in three ways including the use of an idealized numerical simulation, verifying a fluid mass calibration with high-speed digital photography, and by measuring mass loss in more than 30 hybrid rocket motor firings. Dynamic response of the mass balance was assessed through weight calibration and used to derive spring, damping, and mass moment of inertia coefficients for the TSMB. These dynamic coefficients were used to determine the mass flow rate and total mass loss within an acrylic and gaseous oxygen hybrid rocket motor firing. Intentional variations in the oxygen flow rate resulted in corresponding variations in the total propellant mass flow as expected. The TSMB was optimized to determine mass losses of up to 2.5 g and measured total mass loss to within 2.5% of that calculated by a NIST-calibrated digital scale. Using this method, a mass flow resolution of 0.0011 g/s or 2% of the average mass flow in this study has been achieved.

  1. Invited Article: Time accurate mass flow measurements of solid-fueled systems

    NASA Astrophysics Data System (ADS)

    Olliges, Jordan D.; Lilly, Taylor C.; Joslyn, Thomas B.; Ketsdever, Andrew D.

    2008-10-01

    A novel diagnostic method is described that utilizes a thrust stand mass balance (TSMB) to directly measure time-accurate mass flow from a solid-fuel thruster. The accuracy of the TSMB mass flow measurement technique was demonstrated in three ways including the use of an idealized numerical simulation, verifying a fluid mass calibration with high-speed digital photography, and by measuring mass loss in more than 30 hybrid rocket motor firings. Dynamic response of the mass balance was assessed through weight calibration and used to derive spring, damping, and mass moment of inertia coefficients for the TSMB. These dynamic coefficients were used to determine the mass flow rate and total mass loss within an acrylic and gaseous oxygen hybrid rocket motor firing. Intentional variations in the oxygen flow rate resulted in corresponding variations in the total propellant mass flow as expected. The TSMB was optimized to determine mass losses of up to 2.5 g and measured total mass loss to within 2.5% of that calculated by a NIST-calibrated digital scale. Using this method, a mass flow resolution of 0.0011 g/s or 2% of the average mass flow in this study has been achieved.

  2. Home Circadian Phase Assessments with Measures of Compliance Yield Accurate Dim Light Melatonin Onsets

    PubMed Central

    Burgess, Helen J.; Wyatt, James K.; Park, Margaret; Fogg, Louis F.

    2015-01-01

    Study Objectives: There is a need for the accurate assessment of circadian phase outside of the clinic/laboratory, particularly with the gold standard dim light melatonin onset (DLMO). We tested a novel kit designed to assist in saliva sampling at home for later determination of the DLMO. The home kit includes objective measures of compliance to the requirements for dim light and half-hourly saliva sampling. Design: Participants were randomized to one of two 10-day protocols. Each protocol consisted of two back-to-back home and laboratory phase assessments in counterbalanced order, separated by a 5-day break. Setting: Laboratory or participants' homes. Participants: Thirty-five healthy adults, age 21–62 y. Interventions: N/A. Measurements and Results: Most participants received at least one 30-sec epoch of light > 50 lux during the home phase assessments (average light intensity 4.5 lux), but on average for < 9 min of the required 8.5 h. Most participants collected every saliva sample within 5 min of the scheduled time. Ninety-two percent of home DLMOs were not affected by light > 50 lux or sampling errors. There was no significant difference between the home and laboratory DLMOs (P > 0.05); on average the home DLMOs occurred 9.6 min before the laboratory DLMOs. The home DLMOs were highly correlated with the laboratory DLMOs (r = 0.91, P < 0.001). Conclusions: Participants were reasonably compliant to the home phase assessment procedures. The good agreement between the home and laboratory dim light melatonin onsets (DLMOs) demonstrates that including objective measures of light exposure and sample timing during home saliva sampling can lead to accurate home DLMOs. Clinical Trial Registration: Circadian Phase Assessments at Home, http://clinicaltrials.gov/show/NCT01487252, NCT01487252. Citation: Burgess HJ, Wyatt JK, Park M, Fogg LF. Home circadian phase assessments with measures of compliance yield accurate dim light melatonin onsets. SLEEP 2015;38(6):889–897

  3. No galaxy left behind: accurate measurements with the faintest objects in the Dark Energy Survey

    NASA Astrophysics Data System (ADS)

    Suchyta, E.; Huff, E. M.; Aleksić, J.; Melchior, P.; Jouvel, S.; MacCrann, N.; Ross, A. J.; Crocce, M.; Gaztanaga, E.; Honscheid, K.; Leistedt, B.; Peiris, H. V.; Rykoff, E. S.; Sheldon, E.; Abbott, T.; Abdalla, F. B.; Allam, S.; Banerji, M.; Benoit-Lévy, A.; Bertin, E.; Brooks, D.; Burke, D. L.; Carnero Rosell, A.; Carrasco Kind, M.; Carretero, J.; Cunha, C. E.; D'Andrea, C. B.; da Costa, L. N.; DePoy, D. L.; Desai, S.; Diehl, H. T.; Dietrich, J. P.; Doel, P.; Eifler, T. F.; Estrada, J.; Evrard, A. E.; Flaugher, B.; Fosalba, P.; Frieman, J.; Gerdes, D. W.; Gruen, D.; Gruendl, R. A.; James, D. J.; Jarvis, M.; Kuehn, K.; Kuropatkin, N.; Lahav, O.; Lima, M.; Maia, M. A. G.; March, M.; Marshall, J. L.; Miller, C. J.; Miquel, R.; Neilsen, E.; Nichol, R. C.; Nord, B.; Ogando, R.; Percival, W. J.; Reil, K.; Roodman, A.; Sako, M.; Sanchez, E.; Scarpine, V.; Sevilla-Noarbe, I.; Smith, R. C.; Soares-Santos, M.; Sobreira, F.; Swanson, M. E. C.; Tarle, G.; Thaler, J.; Thomas, D.; Vikram, V.; Walker, A. R.; Wechsler, R. H.; Zhang, Y.; DES Collaboration

    2016-03-01

    Accurate statistical measurement with large imaging surveys has traditionally required throwing away a sizable fraction of the data. This is because most measurements have relied on selecting nearly complete samples, where variations in the composition of the galaxy population with seeing, depth, or other survey characteristics are small. We introduce a new measurement method that aims to minimize this wastage, allowing precision measurement for any class of detectable stars or galaxies. We have implemented our proposal in BALROG, software which embeds fake objects in real imaging to accurately characterize measurement biases. We demonstrate this technique with an angular clustering measurement using Dark Energy Survey (DES) data. We first show that recovery of our injected galaxies depends on a variety of survey characteristics in the same way as the real data. We then construct a flux-limited sample of the faintest galaxies in DES, chosen specifically for their sensitivity to depth and seeing variations. Using the synthetic galaxies as randoms in the Landy-Szalay estimator suppresses the effects of variable survey selection by at least two orders of magnitude. With this correction, our measured angular clustering is found to be in excellent agreement with that of a matched sample from much deeper, higher resolution space-based Cosmological Evolution Survey (COSMOS) imaging; over angular scales of 0.004° < θ < 0.2°, we find a best-fitting scaling amplitude between the DES and COSMOS measurements of 1.00 ± 0.09. We expect this methodology to be broadly useful for extending measurements' statistical reach in a variety of upcoming imaging surveys.

  4. Student-Valued Measurable Teaching Behaviors of Award-Winning Pharmacy Preceptors.

    PubMed

    O'Sullivan, Teresa A; Lau, Carmen; Patel, Mitul; Mac, Chi; Krueger, Janelle; Danielson, Jennifer; Weber, Stanley S

    2015-12-25

    To identify specific preceptor teaching-coaching, role modeling, and facilitating behaviors valued by pharmacy students and to develop measures of those behaviors that can be used for an experiential education quality assurance program. Using a qualitative research approach, we conducted a thematic analysis of student comments about excellent preceptors to identify behaviors exhibited by those preceptors. Identified behaviors were sorted according to the preceptor's role as role model, teacher/coach, or learning facilitator; measurable descriptors for each behavior were then developed. Data analysis resulted in identification of 15 measurable behavior themes, the most frequent being: having an interest in student learning and success, making time for students, and displaying a positive preceptor attitude. Measureable descriptors were developed for 5 role-modeling behaviors, 6 teaching-coaching behaviors, and 4 facilitating behaviors. Preceptors may need to be evaluated in their separate roles as teacher-coach, role model, and learning facilitator. The developed measures in this report could be used in site quality evaluation.

  5. Behavioral Phenotyping of Murine Disease Models with the Integrated Behavioral Station (INBEST).

    PubMed

    Sakic, Boris; Cooper, Marcella P A; Taylor, Sarah E; Stojanovic, Milica; Zagorac, Bosa; Kapadia, Minesh

    2015-04-23

    Due to rapid advances in genetic engineering, small rodents have become the preferred subjects in many disciplines of biomedical research. In studies of chronic CNS disorders, there is an increasing demand for murine models with high validity at the behavioral level. However, multiple pathogenic mechanisms and complex functional deficits often impose challenges to reliably measure and interpret behavior of chronically sick mice. Therefore, the assessment of peripheral pathology and a behavioral profile at several time points using a battery of tests are required. Video-tracking, behavioral spectroscopy, and remote acquisition of physiological measures are emerging technologies that allow for comprehensive, accurate, and unbiased behavioral analysis in a home-base-like setting. This report describes a refined phenotyping protocol, which includes a custom-made monitoring apparatus (Integrated Behavioral Station, INBEST) that focuses on prolonged measurements of basic functional outputs, such as spontaneous activity, food/water intake and motivated behavior in a relatively stress-free environment. Technical and conceptual improvements in INBEST design may further promote reproducibility and standardization of behavioral studies.

  6. Accurate Measurements of Aircraft Engine Soot Emissions Using a CAPS PMssa Monitor

    NASA Astrophysics Data System (ADS)

    Onasch, Timothy; Thompson, Kevin; Renbaum-Wolff, Lindsay; Smallwood, Greg; Make-Lye, Richard; Freedman, Andrew

    2016-04-01

    We present results of aircraft engine soot emissions measurements during the VARIAnT2 campaign using CAPS PMssa monitors. VARIAnT2, an aircraft engine non-volatile particulate matter (nvPM) emissions field campaign, was focused on understanding the variability in nvPM mass measurements using different measurement techniques and accounting for possible nvPM sampling system losses. The CAPS PMssa monitor accurately measures both the optical extinction and scattering (and thus single scattering albedo and absorption) of an extracted sample using the same sample volume for both measurements with a time resolution of 1 second and sensitivity of better than 1 Mm-1. Absorption is obtained by subtracting the scattering signal from the total extinction. Given that the single scattering albedo of the particulates emitted from the aircraft engine measured at both 630 and 660 nm was on the order of 0.1, any inaccuracy in the scattering measurement has little impact on the accuracy of the ddetermined absorption coefficient. The absorption is converted into nvPM mass using a documented Mass Absorption Coefficient (MAC). Results of soot emission indices (mass soot emitted per mass of fuel consumed) for a turbojet engine as a function of engine power will be presented and compared to results obtained using an EC/OC monitor.

  7. Experimental Influences in the Accurate Measurement of Cartilage Thickness in MRI.

    PubMed

    Wang, Nian; Badar, Farid; Xia, Yang

    2018-01-01

    Objective To study the experimental influences to the measurement of cartilage thickness by magnetic resonance imaging (MRI). Design The complete thicknesses of healthy and trypsin-degraded cartilage were measured at high-resolution MRI under different conditions, using two intensity-based imaging sequences (ultra-short echo [UTE] and multislice-multiecho [MSME]) and 3 quantitative relaxation imaging sequences (T 1 , T 2 , and T 1 ρ). Other variables included different orientations in the magnet, 2 soaking solutions (saline and phosphate buffered saline [PBS]), and external loading. Results With cartilage soaked in saline, UTE and T 1 methods yielded complete and consistent measurement of cartilage thickness, while the thickness measurement by T 2 , T 1 ρ, and MSME methods were orientation dependent. The effect of external loading on cartilage thickness is also sequence and orientation dependent. All variations in cartilage thickness in MRI could be eliminated with the use of a 100 mM PBS or imaged by UTE sequence. Conclusions The appearance of articular cartilage and the measurement accuracy of cartilage thickness in MRI can be influenced by a number of experimental factors in ex vivo MRI, from the use of various pulse sequences and soaking solutions to the health of the tissue. T 2 -based imaging sequence, both proton-intensity sequence and quantitative relaxation sequence, similarly produced the largest variations. With adequate resolution, the accurate measurement of whole cartilage tissue in clinical MRI could be utilized to detect differences between healthy and osteoarthritic cartilage after compression.

  8. No Galaxy Left Behind: Accurate Measurements with the Faintest Objects in the Dark Energy Survey

    DOE PAGES

    Suchyta, E.

    2016-01-27

    Accurate statistical measurement with large imaging surveys has traditionally required throwing away a sizable fraction of the data. This is because most measurements have have relied on selecting nearly complete samples, where variations in the composition of the galaxy population with seeing, depth, or other survey characteristics are small. We introduce a new measurement method that aims to minimize this wastage, allowing precision measurement for any class of stars or galaxies detectable in an imaging survey. We have implemented our proposal in Balrog, a software package which embeds fake objects in real imaging in order to accurately characterize measurement biases.more » We also demonstrate this technique with an angular clustering measurement using Dark Energy Survey (DES) data. We first show that recovery of our injected galaxies depends on a wide variety of survey characteristics in the same way as the real data. We then construct a flux-limited sample of the faintest galaxies in DES, chosen specifically for their sensitivity to depth and seeing variations. Using the synthetic galaxies as randoms in the standard LandySzalay correlation function estimator suppresses the effects of variable survey selection by at least two orders of magnitude. Now our measured angular clustering is found to be in excellent agreement with that of a matched sample drawn from much deeper, higherresolution space-based COSMOS imaging; over angular scales of 0.004° < θ < 0.2 ° , we find a best-fit scaling amplitude between the DES and COSMOS measurements of 1.00 ± 0.09. We expect this methodology to be broadly useful for extending the statistical reach of measurements in a wide variety of coming imaging surveys.« less

  9. An Accurate Method for Measuring Airplane-Borne Conformal Antenna's Radar Cross Section

    NASA Astrophysics Data System (ADS)

    Guo, Shuxia; Zhang, Lei; Wang, Yafeng; Hu, Chufeng

    2016-09-01

    The airplane-borne conformal antenna attaches itself tightly with the airplane skin, so the conventional measurement method cannot determine the contribution of the airplane-borne conformal antenna to its radar cross section (RCS). This paper uses the 2D microwave imaging to isolate and extract the distribution of the reflectivity of the airplane-borne conformal antenna. It obtains the 2D spatial spectra of the conformal antenna through the wave spectral transform between the 2D spatial image and the 2D spatial spectrum. After the interpolation from the rectangular coordinate domain to the polar coordinate domain, the spectral domain data for the variation of the scatter of the conformal antenna with frequency and angle is obtained. The experimental results show that the measurement method proposed in this paper greatly enhances the airplane-borne conformal antenna's RCS measurement accuracy, essentially eliminates the influences caused by the airplane skin and more accurately reveals the airplane-borne conformal antenna's RCS scatter properties.

  10. Measuring fire behavior with photography

    Treesearch

    Hubert B. Clements; Darold E. Ward; Carl W. Adkins

    1983-01-01

    Photography is practical for recording and measuring some aspects of forest fire behavior if the scale and perspective can be determined. This paper describes a photogrammetric method for measuring flame height and rate of spread for fires on flat terrain. The flames are photographed at known times with a camera in front of the advancing fire. Scale and perspective of...

  11. Are external knee load and EMG measures accurate indicators of internal knee contact forces during gait?

    PubMed

    Meyer, Andrew J; D'Lima, Darryl D; Besier, Thor F; Lloyd, David G; Colwell, Clifford W; Fregly, Benjamin J

    2013-06-01

    Mechanical loading is believed to be a critical factor in the development and treatment of knee osteoarthritis. However, the contact forces to which the knee articular surfaces are subjected during daily activities cannot be measured clinically. Thus, the ability to predict internal knee contact forces accurately using external measures (i.e., external knee loads and muscle electromyographic [EMG] signals) would be clinically valuable. We quantified how well external knee load and EMG measures predict internal knee contact forces during gait. A single subject with a force-measuring tibial prosthesis and post-operative valgus alignment performed four gait patterns (normal, medial thrust, walking pole, and trunk sway) to induce a wide range of external and internal knee joint loads. Linear regression analyses were performed to assess how much of the variability in internal contact forces was accounted for by variability in the external measures. Though the different gait patterns successfully induced significant changes in the external and internal quantities, changes in external measures were generally weak indicators of changes in total, medial, and lateral contact force. Our results suggest that when total contact force may be changing, caution should be exercised when inferring changes in knee contact forces based on observed changes in external knee load and EMG measures. Advances in musculoskeletal modeling methods may be needed for accurate estimation of in vivo knee contact forces. Copyright © 2012 Orthopaedic Research Society.

  12. Accurate mass measurement by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry. I. Measurement of positive radical ions using porphyrin standard reference materials.

    PubMed

    Griffiths, Nia W; Wyatt, Mark F; Kean, Suzanna D; Graham, Andrew E; Stein, Bridget K; Brenton, A Gareth

    2010-06-15

    A method for the accurate mass measurement of positive radical ions by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) is described. Initial use of a conjugated oligomeric calibration material was rejected in favour of a series of meso-tetraalkyl/tetraalkylaryl-functionalised porphyrins, from which the two calibrants required for a particular accurate mass measurement were chosen. While all measurements of monoisotopic species were within +/-5 ppm, and the method was rigorously validated using chemometrics, mean values of five measurements were used for extra confidence in the generation of potential elemental formulae. Potential difficulties encountered when measuring compounds containing multi-isotopic elements are discussed, where the monoisotopic peak is no longer the lowest mass peak, and a simple mass-correction solution can be applied. The method requires no significant expertise to implement, but care and attention is required to obtain valid measurements. The method is operationally simple and will prove useful to the analytical chemistry community. Copyright (c) 2010 John Wiley & Sons, Ltd.

  13. Sexing adult black-legged kittiwakes by DNA, behavior, and morphology

    USGS Publications Warehouse

    Jodice, P.G.R.; Lanctot, Richard B.; Gill, V.A.; Roby, D.D.; Hatch, Shyla A.

    2000-01-01

    We sexed adult Black-legged Kittiwakes (Rissa tridactyla) using DNA-based genetic techniques, behavior and morphology and compared results from these techniques. Genetic and morphology data were collected on 605 breeding kittiwakes and sex-specific behaviors were recorded for a sub-sample of 285 of these individuals. We compared sex classification based on both genetic and behavioral techniques for this sub-sample to assess the accuracy of the genetic technique. DNA-based techniques correctly sexed 97.2% and sex-specific behaviors, 96.5% of this sub-sample. We used the corrected genetic classifications from this sub-sample and the genetic classifications for the remaining birds, under the assumption they were correct, to develop predictive morphometric discriminant function models for all 605 birds. These models accurately predicted the sex of 73-96% of individuals examined, depending on the sample of birds used and the characters included. The most accurate single measurement for determining sex was length of head plus bill, which correctly classified 88% of individuals tested. When both members of a pair were measured, classification levels improved and approached the accuracy of both behavioral observations and genetic analyses. Morphometric techniques were only slightly less accurate than genetic techniques but were easier to implement in the field and less costly. Behavioral observations, while highly accurate, required that birds be easily observable during the breeding season and that birds be identifiable. As such, sex-specific behaviors may best be applied as a confirmation of sex for previously marked birds. All three techniques thus have the potential to be highly accurate, and the selection of one or more will depend on the circumstances of any particular field study.

  14. Behavioral Dynamics in Swimming: The Appropriate Use of Inertial Measurement Units.

    PubMed

    Guignard, Brice; Rouard, Annie; Chollet, Didier; Seifert, Ludovic

    2017-01-01

    Motor control in swimming can be analyzed using low- and high-order parameters of behavior. Low-order parameters generally refer to the superficial aspects of movement (i.e., position, velocity, acceleration), whereas high-order parameters capture the dynamics of movement coordination. To assess human aquatic behavior, both types have usually been investigated with multi-camera systems, as they offer high three-dimensional spatial accuracy. Research in ecological dynamics has shown that movement system variability can be viewed as a functional property of skilled performers, helping them adapt their movements to the surrounding constraints. Yet to determine the variability of swimming behavior, a large number of stroke cycles (i.e., inter-cyclic variability) has to be analyzed, which is impossible with camera-based systems as they simply record behaviors over restricted volumes of water. Inertial measurement units (IMUs) were designed to explore the parameters and variability of coordination dynamics. These light, transportable and easy-to-use devices offer new perspectives for swimming research because they can record low- to high-order behavioral parameters over long periods. We first review how the low-order behavioral parameters (i.e., speed, stroke length, stroke rate) of human aquatic locomotion and their variability can be assessed using IMUs. We then review the way high-order parameters are assessed and the adaptive role of movement and coordination variability in swimming. We give special focus to the circumstances in which determining the variability between stroke cycles provides insight into how behavior oscillates between stable and flexible states to functionally respond to environmental and task constraints. The last section of the review is dedicated to practical recommendations for coaches on using IMUs to monitor swimming performance. We therefore highlight the need for rigor in dealing with these sensors appropriately in water. We explain the

  15. Behavioral Dynamics in Swimming: The Appropriate Use of Inertial Measurement Units

    PubMed Central

    Guignard, Brice; Rouard, Annie; Chollet, Didier; Seifert, Ludovic

    2017-01-01

    Motor control in swimming can be analyzed using low- and high-order parameters of behavior. Low-order parameters generally refer to the superficial aspects of movement (i.e., position, velocity, acceleration), whereas high-order parameters capture the dynamics of movement coordination. To assess human aquatic behavior, both types have usually been investigated with multi-camera systems, as they offer high three-dimensional spatial accuracy. Research in ecological dynamics has shown that movement system variability can be viewed as a functional property of skilled performers, helping them adapt their movements to the surrounding constraints. Yet to determine the variability of swimming behavior, a large number of stroke cycles (i.e., inter-cyclic variability) has to be analyzed, which is impossible with camera-based systems as they simply record behaviors over restricted volumes of water. Inertial measurement units (IMUs) were designed to explore the parameters and variability of coordination dynamics. These light, transportable and easy-to-use devices offer new perspectives for swimming research because they can record low- to high-order behavioral parameters over long periods. We first review how the low-order behavioral parameters (i.e., speed, stroke length, stroke rate) of human aquatic locomotion and their variability can be assessed using IMUs. We then review the way high-order parameters are assessed and the adaptive role of movement and coordination variability in swimming. We give special focus to the circumstances in which determining the variability between stroke cycles provides insight into how behavior oscillates between stable and flexible states to functionally respond to environmental and task constraints. The last section of the review is dedicated to practical recommendations for coaches on using IMUs to monitor swimming performance. We therefore highlight the need for rigor in dealing with these sensors appropriately in water. We explain the

  16. System to measure accurate temperature dependence of electric conductivity down to 20 K in ultrahigh vacuum.

    PubMed

    Sakai, C; Takeda, S N; Daimon, H

    2013-07-01

    We have developed the new in situ electrical-conductivity measurement system which can be operated in ultrahigh vacuum (UHV) with accurate temperature measurement down to 20 K. This system is mainly composed of a new sample-holder fixing mechanism, a new movable conductivity-measurement mechanism, a cryostat, and two receptors for sample- and four-probe holders. Sample-holder is pushed strongly against the receptor, which is connected to a cryostat, by using this new sample-holder fixing mechanism to obtain high thermal conductivity. Test pieces on the sample-holders have been cooled down to about 20 K using this fixing mechanism, although they were cooled down to only about 60 K without this mechanism. Four probes are able to be touched to a sample surface using this new movable conductivity-measurement mechanism for measuring electrical conductivity after making film on substrates or obtaining clean surfaces by cleavage, flashing, and so on. Accurate temperature measurement is possible since the sample can be transferred with a thermocouple and∕or diode being attached directly to the sample. A single crystal of Bi-based copper oxide high-Tc superconductor (HTSC) was cleaved in UHV to obtain clean surface, and its superconducting critical temperature has been successfully measured in situ. The importance of in situ measurement of resistance in UHV was demonstrated for this HTSC before and after cesium (Cs) adsorption on its surface. The Tc onset increase and the Tc offset decrease by Cs adsorption were observed.

  17. A practical strategy for the accurate measurement of residual dipolar couplings in strongly aligned small molecules

    NASA Astrophysics Data System (ADS)

    Liu, Yizhou; Cohen, Ryan D.; Martin, Gary E.; Williamson, R. Thomas

    2018-06-01

    Accurate measurement of residual dipolar couplings (RDCs) requires an appropriate degree of alignment in order to optimize data quality. An overly weak alignment yields very small anisotropic data that are susceptible to measurement errors, whereas an overly strong alignment introduces extensive anisotropic effects that severely degrade spectral quality. The ideal alignment amplitude also depends on the specific pulse sequence used for the coupling measurement. In this work, we introduce a practical strategy for the accurate measurement of one-bond 13C-1H RDCs up to a range of ca. -300 to +300 Hz, corresponding to an alignment that is an order of magnitude stronger than typically employed for small molecule structural elucidation. This strong alignment was generated in the mesophase of the commercially available poly-γ-(benzyl-L-glutamate) polymer. The total coupling was measured by the simple and well-studied heteronuclear two-dimensional J-resolved experiment, which performs well in the presence of strong anisotropic effects. In order to unequivocally determine the sign of the total coupling and resolve ambiguities in assigning total couplings in the CH2 group, coupling measurements were conducted at an isotropic condition plus two anisotropic conditions of different alignment amplitudes. Most RDCs could be readily extracted from these measurements whereas more complicated spectral effects resulting from strong homonuclear coupling could be interpreted either theoretically or by simulation. Importantly, measurement of these very large RDCs actually offers significantly improved data quality and utility for the structure determination of small organic molecules.

  18. Domain-Specific Relationships in Sexual Measures of Impulsive Behavior.

    PubMed

    Mahoney, Colin T; Lawyer, Steven R

    2018-04-25

    Impulsivity is an important construct for understanding sexual behaviors, but behavioral and self-report measures of impulsivity often are not correlated. One possible explanation for this is that there is little shared variance in the measures because behavioral measures index impulsivity by asking questions about monetary preferences, while self-report measures index impulsivity by asking about a broad range of real-world outcomes (including those of a sexual nature) largely unrelated to money-related preferences. Undergraduate students (total N = 105; female n = 77, male n = 28) completed laboratory measures-delay discounting (DD) and probability discounting (PD)-for two different outcomes-money and sexual activity. Participants also completed the Delaying Gratification Inventory (DGI), which measures difficulty with delaying gratification (i.e., impulsivity) across different domains, including money and physical pleasures. Findings indicated that DD and PD for money were not related to any of the DGI subscales. However, DD for sexual activity was significantly related to the DGI Physical Pleasures subscale, but not other subscales. These findings suggest that the relationship between behavioral and self-report measures of impulsive choice may be stronger when both are measuring domain-specific rather than domain-general behavioral patterns, but further research is warranted.

  19. Compensation method for obtaining accurate, sub-micrometer displacement measurements of immersed specimens using electronic speckle interferometry.

    PubMed

    Fazio, Massimo A; Bruno, Luigi; Reynaud, Juan F; Poggialini, Andrea; Downs, J Crawford

    2012-03-01

    We proposed and validated a compensation method that accounts for the optical distortion inherent in measuring displacements on specimens immersed in aqueous solution. A spherically-shaped rubber specimen was mounted and pressurized on a custom apparatus, with the resulting surface displacements recorded using electronic speckle pattern interferometry (ESPI). Point-to-point light direction computation is achieved by a ray-tracing strategy coupled with customized B-spline-based analytical representation of the specimen shape. The compensation method reduced the mean magnitude of the displacement error induced by the optical distortion from 35% to 3%, and ESPI displacement measurement repeatability showed a mean variance of 16 nm at the 95% confidence level for immersed specimens. The ESPI interferometer and numerical data analysis procedure presented herein provide reliable, accurate, and repeatable measurement of sub-micrometer deformations obtained from pressurization tests of spherically-shaped specimens immersed in aqueous salt solution. This method can be used to quantify small deformations in biological tissue samples under load, while maintaining the hydration necessary to ensure accurate material property assessment.

  20. Generalized weighted ratio method for accurate turbidity measurement over a wide range.

    PubMed

    Liu, Hongbo; Yang, Ping; Song, Hong; Guo, Yilu; Zhan, Shuyue; Huang, Hui; Wang, Hangzhou; Tao, Bangyi; Mu, Quanquan; Xu, Jing; Li, Dejun; Chen, Ying

    2015-12-14

    Turbidity measurement is important for water quality assessment, food safety, medicine, ocean monitoring, etc. In this paper, a method that accurately estimates the turbidity over a wide range is proposed, where the turbidity of the sample is represented as a weighted ratio of the scattered light intensities at a series of angles. An improvement in the accuracy is achieved by expanding the structure of the ratio function, thus adding more flexibility to the turbidity-intensity fitting. Experiments have been carried out with an 850 nm laser and a power meter fixed on a turntable to measure the light intensity at different angles. The results show that the relative estimation error of the proposed method is 0.58% on average for a four-angle intensity combination for all test samples with a turbidity ranging from 160 NTU to 4000 NTU.

  1. Accurate measurement of junctional conductance between electrically coupled cells with dual whole-cell voltage-clamp under conditions of high series resistance.

    PubMed

    Hartveit, Espen; Veruki, Margaret Lin

    2010-03-15

    Accurate measurement of the junctional conductance (G(j)) between electrically coupled cells can provide important information about the functional properties of coupling. With the development of tight-seal, whole-cell recording, it became possible to use dual, single-electrode voltage-clamp recording from pairs of small cells to measure G(j). Experiments that require reduced perturbation of the intracellular environment can be performed with high-resistance pipettes or the perforated-patch technique, but an accompanying increase in series resistance (R(s)) compromises voltage-clamp control and reduces the accuracy of G(j) measurements. Here, we present a detailed analysis of methodologies available for accurate determination of steady-state G(j) and related parameters under conditions of high R(s), using continuous or discontinuous single-electrode voltage-clamp (CSEVC or DSEVC) amplifiers to quantify the parameters of different equivalent electrical circuit model cells. Both types of amplifiers can provide accurate measurements of G(j), with errors less than 5% for a wide range of R(s) and G(j) values. However, CSEVC amplifiers need to be combined with R(s)-compensation or mathematical correction for the effects of nonzero R(s) and finite membrane resistance (R(m)). R(s)-compensation is difficult for higher values of R(s) and leads to instability that can damage the recorded cells. Mathematical correction for R(s) and R(m) yields highly accurate results, but depends on accurate estimates of R(s) throughout an experiment. DSEVC amplifiers display very accurate measurements over a larger range of R(s) values than CSEVC amplifiers and have the advantage that knowledge of R(s) is unnecessary, suggesting that they are preferable for long-duration experiments and/or recordings with high R(s). Copyright (c) 2009 Elsevier B.V. All rights reserved.

  2. Fast and accurate enzyme activity measurements using a chip-based microfluidic calorimeter.

    PubMed

    van Schie, Morten M C H; Ebrahimi, Kourosh Honarmand; Hagen, Wilfred R; Hagedoorn, Peter-Leon

    2018-03-01

    Recent developments in microfluidic and nanofluidic technologies have resulted in development of new chip-based microfluidic calorimeters with potential use in different fields. One application would be the accurate high-throughput measurement of enzyme activity. Calorimetry is a generic way to measure activity of enzymes, but unlike conventional calorimeters, chip-based calorimeters can be easily automated and implemented in high-throughput screening platforms. However, application of chip-based microfluidic calorimeters to measure enzyme activity has been limited due to problems associated with miniaturization such as incomplete mixing and a decrease in volumetric heat generated. To address these problems we introduced a calibration method and devised a convenient protocol for using a chip-based microfluidic calorimeter. Using the new calibration method, the progress curve of alkaline phosphatase, which has product inhibition for phosphate, measured by the calorimeter was the same as that recorded by UV-visible spectroscopy. Our results may enable use of current chip-based microfluidic calorimeters in a simple manner as a tool for high-throughput screening of enzyme activity with potential applications in drug discovery and enzyme engineering. Copyright © 2017. Published by Elsevier Inc.

  3. Measuring behavioral regulation in four societies

    PubMed Central

    Wanless, Shannon B.; McClelland, Megan M.; Acock, Alan C.; Ponitz, Claire C.; Son, Seung-Hee; Lan, Xuezhao; Morrison, Frederick J.; Chen, Jo-Lin; Chen, Taiwan Fu-Mei; Lee, Taiwan Kangyi; Sung, Miyoung; Li, Su

    2010-01-01

    The present study examined the psychometric properties of scores from a direct measure of behavioral regulation, the Head-Toes-Knees-Shoulders task (HTKS) with 3- to 6-year-old children in the U.S., Taiwan, South Korea, and China. Specifically, we investigated (1) the nature and variability of HTKS scores including relations to teacher-rated classroom behavioral regulation, and (2) relations between the HTKS and early mathematics, vocabulary, and literacy skills. Higher HTKS scores were significantly related to higher teacher ratings of classroom behavioral regulation in the U.S. and South Korea but not in Taiwan and China. Also, higher HTKS scores were significantly related to higher early mathematics, vocabulary, and literacy skills beyond the influence of demographic variables and teacher-rated classroom behavioral regulation. These initial findings suggest that HTKS scores may be interpreted as reflecting early behavioral regulation in these four societies, and that behavioral regulation is important for early academic success in the U.S. and in Asian countries. PMID:21381840

  4. Swimming behavior of zebrafish is accurately classified by direct modeling and behavioral space analysis

    NASA Astrophysics Data System (ADS)

    Feng, Ruopei; Chemla, Yann; Gruebele, Martin

    Larval zebrafish is a popular organism in the search for the correlation between locomotion behavior and neural pathways because of their highly stereotyped and temporally episodic swimming motion. This correlation is usually investigated using electrophysiological recordings of neural activities in partially immobilized fish. Seeking for a way to study animal behavior without constraints or intruding electrodes, which can in turn modify their behavior, our lab has introduced a parameter-free approach which allows automated classification of the locomotion behaviors of freely swimming fish. We looked into several types of swimming bouts including free swimming and two modes of escape responses and established a new classification of these behaviors. Combined with a neurokinematic model, our analysis showed the capability to probe intrinsic properties of the underlying neural pathways of freely swimming larval zebrafish by inspecting swimming movies only.

  5. Measuring Homework Completion in Behavioral Activation

    ERIC Educational Resources Information Center

    Busch, Andrew M.; Uebelacker, Lisa A.; Kalibatseva, Zornitsa; Miller, Ivan W.

    2010-01-01

    The aim of this study was to develop and validate an observer-based coding system for the characterization and completion of homework assignments during Behavioral Activation (BA). Existing measures of homework completion are generally unsophisticated, and there is no current measure of homework completion designed to capture the particularities…

  6. Method to make accurate concentration and isotopic measurements for small gas samples

    NASA Astrophysics Data System (ADS)

    Palmer, M. R.; Wahl, E.; Cunningham, K. L.

    2013-12-01

    Carbon isotopic ratio measurements of CO2 and CH4 provide valuable insight into carbon cycle processes. However, many of these studies, like soil gas, soil flux, and water head space experiments, provide very small gas sample volumes, too small for direct measurement by current constant-flow Cavity Ring-Down (CRDS) isotopic analyzers. Previously, we addressed this issue by developing a sample introduction module which enabled the isotopic ratio measurement of 40ml samples or smaller. However, the system, called the Small Sample Isotope Module (SSIM), does dilute the sample during the delivery with inert carrier gas which causes a ~5% reduction in concentration. The isotopic ratio measurements are not affected by this small dilution, but researchers are naturally interested accurate concentration measurements. We present the accuracy and precision of a new method of using this delivery module which we call 'double injection.' Two portions of the 40ml of the sample (20ml each) are introduced to the analyzer, the first injection of which flushes out the diluting gas and the second injection is measured. The accuracy of this new method is demonstrated by comparing the concentration and isotopic ratio measurements for a gas sampled directly and that same gas measured through the SSIM. The data show that the CO2 concentration measurements were the same within instrument precision. The isotopic ratio precision (1σ) of repeated measurements was 0.16 permil for CO2 and 1.15 permil for CH4 at ambient concentrations. This new method provides a significant enhancement in the information provided by small samples.

  7. Self-Interaction Chromatography of mAbs: Accurate Measurement of Dead Volumes.

    PubMed

    Hedberg, S H M; Heng, J Y Y; Williams, D R; Liddell, J M

    2015-12-01

    Measurement of the second virial coefficient B22 for proteins using self-interaction chromatography (SIC) is becoming an increasingly important technique for studying their solution behaviour. In common with all physicochemical chromatographic methods, measuring the dead volume of the SIC packed column is crucial for accurate retention data; this paper examines best practise for dead volume determination. SIC type experiments using catalase, BSA, lysozyme and a mAb as model systems are reported, as well as a number of dead column measurements. It was observed that lysozyme and mAb interacted specifically with Toyopearl AF-Formyl dead columns depending upon pH and [NaCl], invalidating their dead volume usage. Toyopearl AF-Amino packed dead columns showed no such problems and acted as suitable dead columns without any solution condition dependency. Dead volume determinations using dextran MW standards with protein immobilised SIC columns provided dead volume estimates close to those obtained using Toyopearl AF-Amino dead columns. It is concluded that specific interactions between proteins, including mAbs, and select SIC support phases can compromise the use of some standard approaches for estimating the dead volume of SIC columns. Two other methods were shown to provide good estimates for the dead volume.

  8. Accurate Energy Consumption Modeling of IEEE 802.15.4e TSCH Using Dual-BandOpenMote Hardware.

    PubMed

    Daneels, Glenn; Municio, Esteban; Van de Velde, Bruno; Ergeerts, Glenn; Weyn, Maarten; Latré, Steven; Famaey, Jeroen

    2018-02-02

    The Time-Slotted Channel Hopping (TSCH) mode of the IEEE 802.15.4e amendment aims to improve reliability and energy efficiency in industrial and other challenging Internet-of-Things (IoT) environments. This paper presents an accurate and up-to-date energy consumption model for devices using this IEEE 802.15.4e TSCH mode. The model identifies all network-related CPU and radio state changes, thus providing a precise representation of the device behavior and an accurate prediction of its energy consumption. Moreover, energy measurements were performed with a dual-band OpenMote device, running the OpenWSN firmware. This allows the model to be used for devices using 2.4 GHz, as well as 868 MHz. Using these measurements, several network simulations were conducted to observe the TSCH energy consumption effects in end-to-end communication for both frequency bands. Experimental verification of the model shows that it accurately models the consumption for all possible packet sizes and that the calculated consumption on average differs less than 3% from the measured consumption. This deviation includes measurement inaccuracies and the variations of the guard time. As such, the proposed model is very suitable for accurate energy consumption modeling of TSCH networks.

  9. Accurate Energy Consumption Modeling of IEEE 802.15.4e TSCH Using Dual-BandOpenMote Hardware

    PubMed Central

    Municio, Esteban; Van de Velde, Bruno; Latré, Steven

    2018-01-01

    The Time-Slotted Channel Hopping (TSCH) mode of the IEEE 802.15.4e amendment aims to improve reliability and energy efficiency in industrial and other challenging Internet-of-Things (IoT) environments. This paper presents an accurate and up-to-date energy consumption model for devices using this IEEE 802.15.4e TSCH mode. The model identifies all network-related CPU and radio state changes, thus providing a precise representation of the device behavior and an accurate prediction of its energy consumption. Moreover, energy measurements were performed with a dual-band OpenMote device, running the OpenWSN firmware. This allows the model to be used for devices using 2.4 GHz, as well as 868 MHz. Using these measurements, several network simulations were conducted to observe the TSCH energy consumption effects in end-to-end communication for both frequency bands. Experimental verification of the model shows that it accurately models the consumption for all possible packet sizes and that the calculated consumption on average differs less than 3% from the measured consumption. This deviation includes measurement inaccuracies and the variations of the guard time. As such, the proposed model is very suitable for accurate energy consumption modeling of TSCH networks. PMID:29393900

  10. Accurate Measurement of Velocity and Acceleration of Seismic Vibrations near Nuclear Power Plants

    NASA Astrophysics Data System (ADS)

    Arif, Syed Javed; Imdadullah; Asghar, Mohammad Syed Jamil

    In spite of all prerequisite geological study based precautions, the sites of nuclear power plants are also susceptible to seismic vibrations and their consequent effects. The effect of the ongoing nuclear tragedy in Japan caused by an earthquake and its consequent tsunami on March 11, 2011 is currently beyond contemplations. It has led to a rethinking on nuclear power stations by various governments around the world. Therefore, the prediction of location and time of large earthquakes has regained a great importance. The earth crust is made up of several wide, thin and rigid plates like blocks which are in constant motion with respect to each other. A series of vibrations on the earth surface are produced by the generation of elastic seismic waves due to sudden rupture within the plates during the release of accumulated strain energy. The range of frequency of seismic vibrations is from 0 to 10 Hz. However, there appears a large variation in magnitude, velocity and acceleration of these vibrations. The response of existing or conventional methods of measurement of seismic vibrations is very slow, which is of the order of tens of seconds. A systematic and high resolution measurement of velocity and acceleration of these vibrations are useful to interpret the pattern of waves and their anomalies more accurately, which are useful for the prediction of an earthquake. In the proposed work, a fast rotating magnetic field (RMF) is used to measure the velocity and acceleration of seismic vibrations in the millisecond range. The broad spectrum of pulses within one second range, measured by proposed method, gives all possible values of instantaneous velocity and instantaneous acceleration of the seismic vibrations. The spectrum of pulses in millisecond range becomes available which is useful to measure the pattern of fore shocks to predict the time and location of large earthquakes more accurately. Moreover, instead of average, the peak values of these quantities are helpful

  11. Advances in Multicollector ICPMS for precise and accurate isotope ratio measurements of Uranium isotopes

    NASA Astrophysics Data System (ADS)

    Bouman, C.; Lloyd, N. S.; Schwieters, J.

    2011-12-01

    The accurate and precise determination of uranium isotopes is challenging, because of the large dynamic range posed by the U isotope abundances and the limited available sample material. Various mass spectrometric techniques are used for the measurement of U isotopes, where TIMS is the most accepted and accurate one. Multicollector inductively coupled plasma mass spectrometry (MC-ICPMS) can offer higher productivity compared to TIMS, but is traditionally limited by low efficiency of sample utilisation. This contribution will discuss progress in MC-ICPMS for detecting 234U, 235U, 236U and 238U in various uranium reference materials from IRMM and NBL. The Thermo Scientific NEPTUNE Plus with Jet Interface offers a modified dry plasma ICP interface using a large interface pump combined with a special set of sample and skimmer cones giving ultimate sensitivity for all elements across the mass range. For uranium, an ion yield of > 3 % was reported previously [1]. The NEPTUNE Plus also offers Multi Ion Counting using discrete dynode electron multipliers as well as two high abundance-sensitivity filters to discriminate against peak tailing effects on 234U and 236U originating from the major uranium beams. These improvements in sensitivity and dynamic range allow accurate measurements of 234U, 235U and 236U abundances on very small samples and at low concentration. In our approach, minor U isotopes 234U and 236U were detected on ion counters with high abundance sensitivity filters, whereas 235U and 238U were detected on Faraday Cups using a high gain current amplifier (10e12 Ohm) for 235U. Precisions and accuracies for 234U and 236U were down to ~1%. For 235U, subpermil levels were reached.

  12. UAV multirotor platform for accurate turbulence measurements in the atmosphere

    NASA Astrophysics Data System (ADS)

    Carbajo Fuertes, Fernando; Wilhelm, Lionel; Sin, Kevin Edgar; Hofer, Matthias; Porté-Agel, Fernando

    2017-04-01

    One of the most challenging tasks in atmospheric field studies for wind energy is to obtain accurate turbulence measurements at any location inside the region of interest for a wind farm study. This volume would ideally include from several hundred meters to several kilometers around it and from ground height to the top of the boundary layer. An array of meteorological masts equipped with several sonic anemometers to cover all points of interest would be the best in terms of accuracy and data availability, but it is an obviously unfeasible solution. On the other hand, the evolution of wind LiDAR technology allows to measure at any point in space but unfortunately it involves two important limitations: the first one is the relatively low spatial and temporal resolution when compared to a sonic anemometer and the second one is the fact that the measurements are limited to the velocity component parallel to the laser beam (radial velocity). To overcome the aforementioned drawbacks, a UAV multirotor platform has been developed. It is based on a state-of-the-art octocopter with enough payload to carry laboratory-grade instruments for the measurement of time-resolved atmospheric pressure, three-component velocity vector and temperature; and enough autonomy to fly from 10 to 20 minutes, which is a standard averaging time in most atmospheric measurement applications. The UAV uses a gyroscope, an accelerometer, a GPS and an algorithm has been developed and integrated for the correction of any orientation and movement. This UAV platform opens many possibilities for the study of features that have been almost exclusively studied until now in wind tunnel such as wind turbine blade tip vortex characteristics, near-wake to far-wake transition, momentum entrainment from the higher part of the boundary layer in wind farms, etc. The validation of this new measurement technique has been performed against sonic anemometry in terms of wind speed and temperature time series as well as

  13. Apparatus for accurate density measurements of fluids based on a magnetic suspension balance

    NASA Astrophysics Data System (ADS)

    Gong, Maoqiong; Li, Huiya; Guo, Hao; Dong, Xueqiang; Wu, J. F.

    2012-06-01

    A new apparatus for accurate pressure, density and temperature (p, ρ, T) measurements over wide ranges of (p, ρ, T) (90 K to 290 K; 0 MPa to 3 MPa; 0 kg/m3 to 2000 kg/m3) is described. This apparatus is based on a magnetic suspension balance which applies the Archimedes' buoyancy principle. In order to verify the new apparatus, comprehensive (p, ρ, T) measurements on pure nitrogen were carried out. The maximum relative standard uncertainty is 0.09% in density. The maximum standard uncertainty in temperature is 5 mK, and that in pressure is 250 Pa for 1.5 MPa and 390 Pa for 3MPa full scale range respectively. The experimental data were compared with selected literature data and good agreements were found.

  14. Root resistance to cavitation is accurately measured using a centrifuge technique.

    PubMed

    Pratt, R B; MacKinnon, E D; Venturas, M D; Crous, C J; Jacobsen, A L

    2015-02-01

    Plants transport water under negative pressure and this makes their xylem vulnerable to cavitation. Among plant organs, root xylem is often highly vulnerable to cavitation due to water stress. The use of centrifuge methods to study organs, such as roots, that have long vessels are hypothesized to produce erroneous estimates of cavitation resistance due to the presence of open vessels through measured samples. The assumption that roots have long vessels may be premature since data for root vessel length are sparse; moreover, recent studies have not supported the existence of a long-vessel artifact for stems when a standard centrifuge technique was used. We examined resistance to cavitation estimated using a standard centrifuge technique and compared these values with native embolism measurements for roots of seven woody species grown in a common garden. For one species we also measured vulnerability using single-vessel air injection. We found excellent agreement between root native embolism and the levels of embolism measured using a centrifuge technique, and with air-seeding estimates from single-vessel injection. Estimates of cavitation resistance measured from centrifuge curves were biologically meaningful and were correlated with field minimum water potentials, vessel diameter (VD), maximum xylem-specific conductivity (Ksmax) and vessel length. Roots did not have unusually long vessels compared with stems; moreover, root vessel length was not correlated to VD or to the vessel length of stems. These results suggest that root cavitation resistance can be accurately and efficiently measured using a standard centrifuge method and that roots are highly vulnerable to cavitation. The role of root cavitation resistance in determining drought tolerance of woody species deserves further study, particularly in the context of climate change. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. An X-band waveguide measurement technique for the accurate characterization of materials with low dielectric loss permittivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allen, Kenneth W., E-mail: kenneth.allen@gtri.gatech.edu; Scott, Mark M.; Reid, David R.

    In this work, we present a new X-band waveguide (WR90) measurement method that permits the broadband characterization of the complex permittivity for low dielectric loss tangent material specimens with improved accuracy. An electrically long polypropylene specimen that partially fills the cross-section is inserted into the waveguide and the transmitted scattering parameter (S{sub 21}) is measured. The extraction method relies on computational electromagnetic simulations, coupled with a genetic algorithm, to match the experimental S{sub 21} measurement. The sensitivity of the technique to sample length was explored by simulating specimen lengths from 2.54 to 15.24 cm, in 2.54 cm increments. Analysis ofmore » our simulated data predicts the technique will have the sensitivity to measure loss tangent values on the order of 10{sup −3} for materials such as polymers with relatively low real permittivity values. The ability to accurately characterize low-loss dielectric material specimens of polypropylene is demonstrated experimentally. The method was validated by excellent agreement with a free-space focused-beam system measurement of a polypropylene sheet. This technique provides the material measurement community with the ability to accurately extract material properties of low-loss material specimen over the entire X-band range. This technique could easily be extended to other frequency bands.« less

  16. A solution for measuring accurate reaction time to visual stimuli realized with a programmable microcontroller.

    PubMed

    Ohyanagi, Toshio; Sengoku, Yasuhito

    2010-02-01

    This article presents a new solution for measuring accurate reaction time (SMART) to visual stimuli. The SMART is a USB device realized with a Cypress Programmable System-on-Chip (PSoC) mixed-signal array programmable microcontroller. A brief overview of the hardware and firmware of the PSoC is provided, together with the results of three experiments. In Experiment 1, we investigated the timing accuracy of the SMART in measuring reaction time (RT) under different conditions of operating systems (OSs; Windows XP or Vista) and monitor displays (a CRT or an LCD). The results indicated that the timing error in measuring RT by the SMART was less than 2 msec, on average, under all combinations of OS and display and that the SMART was tolerant to jitter and noise. In Experiment 2, we tested the SMART with 8 participants. The results indicated that there was no significant difference among RTs obtained with the SMART under the different conditions of OS and display. In Experiment 3, we used Microsoft (MS) PowerPoint to present visual stimuli on the display. We found no significant difference in RTs obtained using MS DirectX technology versus using the PowerPoint file with the SMART. We are certain that the SMART is a simple and practical solution for measuring RTs accurately. Although there are some restrictions in using the SMART with RT paradigms, the SMART is capable of providing both researchers and health professionals working in clinical settings with new ways of using RT paradigms in their work.

  17. Antiepileptic Drug Behavioral Side Effects in Individuals with Mental Retardation and the Use of Behavioral Measurement Techniques.

    ERIC Educational Resources Information Center

    Kalachnik, John E.; And Others

    1995-01-01

    Behavioral psychology measurement methods helped assess antiepileptic drug behavioral side effects in five individuals with mental retardation who could not verbally communicate presence of side effects. When the suspected antiepileptic drug was altered, an 81% reduction of maladaptive behaviors occurred. The measurement methods enabled systematic…

  18. A Brief Measure of Children's Behavior Problems: The Behavior Rating Index for Children.

    ERIC Educational Resources Information Center

    Stiffman, Arlene R.; And Others

    1984-01-01

    Describes the development of the Behavior Rating Index for Children (BRIC), a 13-item summated category partition scale that provides a prothetic measure of children's behavior problems. Evaluation of the BRIC with 600 referred and nonreferred children suggested adequate reliability and validity. (JAC)

  19. Assessing Counter-Terrorism field training with multiple behavioral measures.

    PubMed

    Spiker, V Alan; Johnston, Joan H

    2013-09-01

    Development of behavioral pattern recognition and analysis skills is an essential element of Counter-Terrorism training, particularly in the field. Three classes of behavioral measures were collected in an assessment of skill acquisition during a US Joint Forces Command-sponsored course consisting of Combat Tracking and Combat Profiling segments. Measures included situational judgment tests, structured behavioral observation checklists, and qualitative assessments of the emergence of specific knowledge-skills-attitudes over the course of the training. The paper describes statistical evidence across the three types of measures that indicate that behavioral pattern recognition and analysis skills were successfully acquired by most students (a mix of Army and civilian law enforcement personnel) during the field training exercises. Implications for broader training of these critical skills are also discussed. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  20. Ocean Lidar Measurements of Beam Attenuation and a Roadmap to Accurate Phytoplankton Biomass Estimates

    NASA Astrophysics Data System (ADS)

    Hu, Yongxiang; Behrenfeld, Mike; Hostetler, Chris; Pelon, Jacques; Trepte, Charles; Hair, John; Slade, Wayne; Cetinic, Ivona; Vaughan, Mark; Lu, Xiaomei; Zhai, Pengwang; Weimer, Carl; Winker, David; Verhappen, Carolus C.; Butler, Carolyn; Liu, Zhaoyan; Hunt, Bill; Omar, Ali; Rodier, Sharon; Lifermann, Anne; Josset, Damien; Hou, Weilin; MacDonnell, David; Rhew, Ray

    2016-06-01

    Beam attenuation coefficient, c, provides an important optical index of plankton standing stocks, such as phytoplankton biomass and total particulate carbon concentration. Unfortunately, c has proven difficult to quantify through remote sensing. Here, we introduce an innovative approach for estimating c using lidar depolarization measurements and diffuse attenuation coefficients from ocean color products or lidar measurements of Brillouin scattering. The new approach is based on a theoretical formula established from Monte Carlo simulations that links the depolarization ratio of sea water to the ratio of diffuse attenuation Kd and beam attenuation C (i.e., a multiple scattering factor). On July 17, 2014, the CALIPSO satellite was tilted 30° off-nadir for one nighttime orbit in order to minimize ocean surface backscatter and demonstrate the lidar ocean subsurface measurement concept from space. Depolarization ratios of ocean subsurface backscatter are measured accurately. Beam attenuation coefficients computed from the depolarization ratio measurements compare well with empirical estimates from ocean color measurements. We further verify the beam attenuation coefficient retrievals using aircraft-based high spectral resolution lidar (HSRL) data that are collocated with in-water optical measurements.

  1. An instrument for rapid, accurate, determination of fuel moisture content

    Treesearch

    Stephen S. Sackett

    1980-01-01

    Moisture contents of dead and living fuels are key variables in fire behavior. Accurate, real-time fuel moisture data are required for prescribed burning and wildfire behavior predictions. The convection oven method has become the standard for direct fuel moisture content determination. Efforts to quantify fuel moisture through indirect methods have not been...

  2. Do We Know Whether Researchers and Reviewers are Estimating Risk and Benefit Accurately?

    PubMed

    Hey, Spencer Phillips; Kimmelman, Jonathan

    2016-10-01

    Accurate estimation of risk and benefit is integral to good clinical research planning, ethical review, and study implementation. Some commentators have argued that various actors in clinical research systems are prone to biased or arbitrary risk/benefit estimation. In this commentary, we suggest the evidence supporting such claims is very limited. Most prior work has imputed risk/benefit beliefs based on past behavior or goals, rather than directly measuring them. We describe an approach - forecast analysis - that would enable direct and effective measure of the quality of risk/benefit estimation. We then consider some objections and limitations to the forecasting approach. © 2016 John Wiley & Sons Ltd.

  3. A hybrid solution using computational prediction and measured data to accurately determine process corrections with reduced overlay sampling

    NASA Astrophysics Data System (ADS)

    Noyes, Ben F.; Mokaberi, Babak; Mandoy, Ram; Pate, Alex; Huijgen, Ralph; McBurney, Mike; Chen, Owen

    2017-03-01

    Reducing overlay error via an accurate APC feedback system is one of the main challenges in high volume production of the current and future nodes in the semiconductor industry. The overlay feedback system directly affects the number of dies meeting overlay specification and the number of layers requiring dedicated exposure tools through the fabrication flow. Increasing the former number and reducing the latter number is beneficial for the overall efficiency and yield of the fabrication process. An overlay feedback system requires accurate determination of the overlay error, or fingerprint, on exposed wafers in order to determine corrections to be automatically and dynamically applied to the exposure of future wafers. Since current and future nodes require correction per exposure (CPE), the resolution of the overlay fingerprint must be high enough to accommodate CPE in the overlay feedback system, or overlay control module (OCM). Determining a high resolution fingerprint from measured data requires extremely dense overlay sampling that takes a significant amount of measurement time. For static corrections this is acceptable, but in an automated dynamic correction system this method creates extreme bottlenecks for the throughput of said system as new lots have to wait until the previous lot is measured. One solution is using a less dense overlay sampling scheme and employing computationally up-sampled data to a dense fingerprint. That method uses a global fingerprint model over the entire wafer; measured localized overlay errors are therefore not always represented in its up-sampled output. This paper will discuss a hybrid system shown in Fig. 1 that combines a computationally up-sampled fingerprint with the measured data to more accurately capture the actual fingerprint, including local overlay errors. Such a hybrid system is shown to result in reduced modelled residuals while determining the fingerprint, and better on-product overlay performance.

  4. The extraction of accurate coordinates of images on photographic plates by means of a scanning type measuring machine

    NASA Technical Reports Server (NTRS)

    Ross, B. E.

    1971-01-01

    The Moire method experimental stress analysis is similar to a problem encountered in astrometry. It is necessary to extract accurate coordinates from images on photographic plates. The solution to the mutual problem found applicable to the field of experimental stress analysis is presented to outline the measurement problem. A discussion of the photo-reading device developed to make the measurements follows.

  5. Assessing Pharmacy Students’ Ability to Accurately Measure Blood Pressure Using a Blood Pressure Simulator Arm

    PubMed Central

    Bryant, Ginelle A.; Haack, Sally L.; North, Andrew M.

    2013-01-01

    Objective. To compare student accuracy in measuring normal and high blood pressures using a simulator arm. Methods. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. Results. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; p<0.001). However, there was no difference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Conclusions. Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign. PMID:23788809

  6. Assessing pharmacy students' ability to accurately measure blood pressure using a blood pressure simulator arm.

    PubMed

    Bottenberg, Michelle M; Bryant, Ginelle A; Haack, Sally L; North, Andrew M

    2013-06-12

    To compare student accuracy in measuring normal and high blood pressures using a simulator arm. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; p<0.001). However, there was no difference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign.

  7. Issues Related to Measuring and Interpreting Objectively Measured Sedentary Behavior Data

    ERIC Educational Resources Information Center

    Janssen, Xanne; Cliff, Dylan P.

    2015-01-01

    The use of objective measures of sedentary behavior has increased over the past decade; however, as is the case for objectively measured physical activity, methodological decisions before and after data collection are likely to influence the outcomes. The aim of this article is to review the evidence on different methodological decisions made by…

  8. Accurate measurements of the true column efficiency and of the instrument band broadening contributions in the presence of a chromatographic column.

    PubMed

    Gritti, Fabrice; Guiochon, Georges

    2014-01-31

    A rapid and simple validated experimental protocol is proposed for the accurate determination of the true intrinsic column efficiency and for that of the variance of the extra-column volume of the instrument used, the latter being obtained without requiring the removal of the chromatographic column from the HPLC system. This protocol was applied to 2.1mm×100mm columns packed with sub-3 (2.7μm Halo Peptide ES-C18) and sub-2μm (1.6μm prototype) core-shell particles. It was validated by observing the linear behavior of the plot of the apparent column plate height versus the reciprocal of (1+k')(2) for at least three homologous compounds, with a linear regression coefficient R(2) larger than 0.999. Irrespective of the contribution of the several, different instruments used to the total band broadening, the same column HETP value was obtained within 5%. This new protocol outperform the classical one in which the chromatographic column is replaced with a zero dead volume (ZDV) union connector to measure the extra-column volume variance, which is subtracted from the variance measured with the column to measure the intrinsic HETP. This protocol fails because it significantly underestimates the system volume variance. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Creep Measurement Video Extensometer

    NASA Technical Reports Server (NTRS)

    Jaster, Mark; Vickerman, Mary; Padula, Santo, II; Juhas, John

    2011-01-01

    Understanding material behavior under load is critical to the efficient and accurate design of advanced aircraft and spacecraft. Technologies such as the one disclosed here allow accurate creep measurements to be taken automatically, reducing error. The goal was to develop a non-contact, automated system capable of capturing images that could subsequently be processed to obtain the strain characteristics of these materials during deformation, while maintaining adequate resolution to capture the true deformation response of the material. The measurement system comprises a high-resolution digital camera, computer, and software that work collectively to interpret the image.

  10. How accurate are lexile text measures?

    PubMed

    Stenner, A Jackson; Burdick, Hal; Sanford, Eleanor E; Burdick, Donald S

    2006-01-01

    The Lexile Framework for Reading models comprehension as the difference between a reader measure and a text measure. Uncertainty in comprehension rates results from unreliability in reader measures and inaccuracy in text readability measures. Whole-text processing eliminates sampling error in text measures. However, Lexile text measures are imperfect due to misspecification of the Lexile theory. The standard deviation component associated with theory misspecification is estimated at 64L for a standard-length passage (approximately 125 words). A consequence is that standard errors for longer texts (2,500 to 150,000 words) are measured on the Lexile scale with uncertainties in the single digits. Uncertainties in expected comprehension rates are largely due to imprecision in reader ability and not inaccuracies in text readabilities.

  11. A non-contact method based on multiple signal classification algorithm to reduce the measurement time for accurately heart rate detection

    NASA Astrophysics Data System (ADS)

    Bechet, P.; Mitran, R.; Munteanu, M.

    2013-08-01

    Non-contact methods for the assessment of vital signs are of great interest for specialists due to the benefits obtained in both medical and special applications, such as those for surveillance, monitoring, and search and rescue. This paper investigates the possibility of implementing a digital processing algorithm based on the MUSIC (Multiple Signal Classification) parametric spectral estimation in order to reduce the observation time needed to accurately measure the heart rate. It demonstrates that, by proper dimensioning the signal subspace, the MUSIC algorithm can be optimized in order to accurately assess the heart rate during an 8-28 s time interval. The validation of the processing algorithm performance was achieved by minimizing the mean error of the heart rate after performing simultaneous comparative measurements on several subjects. In order to calculate the error the reference value of heart rate was measured using a classic measurement system through direct contact.

  12. Improving measurement of injection drug risk behavior using item response theory.

    PubMed

    Janulis, Patrick

    2014-03-01

    Recent research highlights the multiple steps to preparing and injecting drugs and the resultant viral threats faced by drug users. This research suggests that more sensitive measurement of injection drug HIV risk behavior is required. In addition, growing evidence suggests there are gender differences in injection risk behavior. However, the potential for differential item functioning between genders has not been explored. To explore item response theory as an improved measurement modeling technique that provides empirically justified scaling of injection risk behavior and to examine for potential gender-based differential item functioning. Data is used from three studies in the National Institute on Drug Abuse's Criminal Justice Drug Abuse Treatment Studies. A two-parameter item response theory model was used to scale injection risk behavior and logistic regression was used to examine for differential item functioning. Item fit statistics suggest that item response theory can be used to scale injection risk behavior and these models can provide more sensitive estimates of risk behavior. Additionally, gender-based differential item functioning is present in the current data. Improved measurement of injection risk behavior using item response theory should be encouraged as these models provide increased congruence between construct measurement and the complexity of injection-related HIV risk. Suggestions are made to further improve injection risk behavior measurement. Furthermore, results suggest direct comparisons of composite scores between males and females may be misleading and future work should account for differential item functioning before comparing levels of injection risk behavior.

  13. Optimal neurocognitive, personality and behavioral measures for assessing impulsivity in cocaine dependence.

    PubMed

    LoBue, Christian; Cullum, C Munro; Braud, Jacqueline; Walker, Robrina; Winhusen, Theresa; Suderajan, Prabha; Adinoff, Bryon

    2014-11-01

    Impulsivity may underlie the poor treatment retention and high relapse rates observed in cocaine-dependent persons. However, observed differences in measures of impulsivity between cocaine-dependent and healthy control participants often do not reach clinical significance, suggesting that the clinical relevance of these differences may be limited. To examine which measures of impulsivity (i.e. self-report impulsivity, self-report personality, neurocognitive testing) best distinguish cocaine-dependent and healthy control participants (i.e. showing differences at least 1.5 standard deviations [SD] from controls). Optimal measures were considered to demonstrate sufficient classification accuracy. Sixty-five recently abstinent cocaine-dependent and 25 healthy control participants were assessed using select neurocognitive tests and self-report questionnaires including the NEO Personality Inventory-Revised (NEO-PI-R), Temperament and Character Inventory (TCI), Barratt Impulsiveness Scale (BIS-11a), and the Frontal Systems Behavior Scale (FrSBe). When corrected for years of education and gender, neurocognitive measures did not demonstrate clinically significant differences between cocaine-dependent and control participants. The personality measures TCI Purposefulness and Congruent Second Nature and NEO-PI-R Impulsiveness, and the self-rating measures FrSBe Disinhibition and BIS-11 Motor Impulsivity and Total successfully identified clinically meaningful elevations in impulsivity within cocaine-dependent participants (>1.5 SDs from controls). Furthermore, these measures achieved 84-93% accuracy in discriminating cocaine-dependent from control participants. Clinically significant neurocognitive impairment in cocaine-dependent participants was not observed in this sample. As the BIS-11 or FrSBe are brief to administer, accurate, and have been shown to predict treatment retention and relapse, these measures appear to be optimal, relative to the personality measures, for

  14. Electrooculography: Connecting Mind, Brain, and Behavior in Mathematics Education Research

    ERIC Educational Resources Information Center

    Shipulina, Olga V.; Campbell, Stephen R.; Cimen, Arda O.

    2009-01-01

    This paper reports on the potential roles and importance of electrooculography (EOG) for mathematics educational neuroscience research. EOG enables accurate measurements of eye-related behavior (i.e., blinks & movements) by recording changes in voltage potentials generated by eye-related behavior. We identify and discuss three main uses of EOG.…

  15. Development and Validation of a Musical Behavior Measure for Preschool Children

    ERIC Educational Resources Information Center

    Yi, Gina Jisun

    2013-01-01

    The purpose of this study was to develop a measure for use in assessing musical behaviors of preschool children in the context of regular music instruction and to determine the validity and the reliability of the measure. The Early Childhood Musical Behavior Measure (ECMBM) was constructed for use with preschool-aged children to measure their…

  16. Easy Leaf Area: Automated digital image analysis for rapid and accurate measurement of leaf area.

    PubMed

    Easlon, Hsien Ming; Bloom, Arnold J

    2014-07-01

    Measurement of leaf areas from digital photographs has traditionally required significant user input unless backgrounds are carefully masked. Easy Leaf Area was developed to batch process hundreds of Arabidopsis rosette images in minutes, removing background artifacts and saving results to a spreadsheet-ready CSV file. • Easy Leaf Area uses the color ratios of each pixel to distinguish leaves and calibration areas from their background and compares leaf pixel counts to a red calibration area to eliminate the need for camera distance calculations or manual ruler scale measurement that other software methods typically require. Leaf areas estimated by this software from images taken with a camera phone were more accurate than ImageJ estimates from flatbed scanner images. • Easy Leaf Area provides an easy-to-use method for rapid measurement of leaf area and nondestructive estimation of canopy area from digital images.

  17. Accurate temperature measurement by temperature field analysis in diamond anvil cell for thermal transport study of matter under high pressures

    NASA Astrophysics Data System (ADS)

    Yue, Donghui; Ji, Tingting; Qin, Tianru; Wang, Jia; Liu, Cailong; Jiao, Hui; Zhao, Lin; Han, Yonghao; Gao, Chunxiao

    2018-02-01

    The study on the thermal transport properties of matter under high pressure is important but is hard to fulfill in a diamond anvil cell (DAC) because the accurate measurement of the temperature gradient within the sample of DAC is very difficult. In most cases, the sample temperature can be read accurately from the thermocouples that are directly attached to the lateral edges of diamond anvils because both the sample and diamond anvils can be uniformly heated up to a given temperature. But for the thermal transport property studies in DAC, an artificial temperature distribution along the compression axis is a prerequisite. Obviously, the temperature of the top or bottom surface of the sample cannot be substituted by that of diamond anvils although diamond anvils can be considered as a good medium for heat conduction. With temperature field simulation by finite element analysis, it is found that big measurement errors can occur and are fatal to the correct analysis of thermal transport properties of materials. Thus, a method of combining both the four-thermocouple configuration and temperature field analysis is presented for the accurate temperature distribution measurement in DAC, which is based on the single-function relationship between temperature distribution and sample thermal conductivity.

  18. A Novel Multimode Waveguide Coupler for Accurate Power Measurement of Traveling Wave Tube Harmonic Frequencies

    NASA Technical Reports Server (NTRS)

    Wintucky, Edwin G.; Simons, Rainee N.

    2014-01-01

    This paper presents the design, fabrication and test results for a novel waveguide multimode directional coupler (MDC). The coupler fabricated from two dissimilar waveguides is capable of isolating the power at the second harmonic frequency from the fundamental power at the output port of a traveling-wave tube (TWT). In addition to accurate power measurements at harmonic frequencies, a potential application of the MDC is in the design of a beacon source for atmospheric propagation studies at millimeter-wave frequencies.

  19. The Driving Behavior Survey as a Measure of Behavioral Stress Responses to MVA-related PTSD

    PubMed Central

    Baker, Aaron S.; Litwack, Scott D.; Clapp, Joshua D.; Beck, J. Gayle; Sloan, Denise M.

    2014-01-01

    Numerous treatments are available that address the core symptoms of posttraumatic stress disorder (PTSD). However, there are a number of related behavioral stress responses that are not assessed with PTSD measures, yet these behavioral stress responses affect quality of life. The goal of the current study was to investigate whether a recently developed measure of behavioral stress response, the Driving Behavior Survey (DBS), was sensitive to change associated with treatment among a group of participants diagnosed with PTSD. The DBS indexes anxious driving behavior, which is frequently observed among individuals with motor vehicle accident-related PTSD. Participants (n = 40) were racially-diverse adults (M age =40.78, 63% women) who met diagnostic criteria for motor vehicle accident-related PTSD. Hierarchical linear modeling analyses indicated that participants who were assigned to a brief, exposure-based intervention displayed significant reductions on the DBS subscales relative to participants assigned to the waitlist control condition (r = .41-.43). Moreover, meditational analyses indicated that the observed reductions on the DBS subscales were not better accounted for by reductions in PTSD. Taken together, these findings suggest that the DBS subscales are sensitive to changes associated with PTSD treatment and can be used to augment outcome measures in PTSD treatment trials PMID:24491201

  20. Development of a New Fundamental Measuring Technique for the Accurate Measurement of Gas Flowrates by Means of Laser Doppler Anemometry

    NASA Astrophysics Data System (ADS)

    Dopheide, D.; Taux, G.; Krey, E.-A.

    1990-01-01

    In the Physikalisch-Technische Bundesanstalt (PTB), a research test facility for the accurate measurement of gas (volume and mass) flowrates has been set up in the last few years on the basis of a laser Doppler anemometer (LDA) with a view to directly measuring gas flowrates with a relative uncertainty of only 0,1%. To achieve this, it was necessary to develop laser Doppler anemometry into a precision measuring technique and to carry out detailed investigations on stationary low-turbulence nozzle flow. The process-computer controlled test facility covers the flowrate range from 100 to 4000 m3/h (~0,03 - 1,0 m3/s), any flowrate being measured directly, immediately and without staggered arrangement of several flow meters. After the development was completed, several turbine-type gas meters were calibrated and international comparisons carried out. The article surveys the most significant aspects of the work and provides an outlook on future developments with regard to the miniaturization of optical flow and flowrate sensors for industrial applications.

  1. History and progress on accurate measurements of the Planck constant

    NASA Astrophysics Data System (ADS)

    Steiner, Richard

    2013-01-01

    The measurement of the Planck constant, h, is entering a new phase. The CODATA 2010 recommended value is 6.626 069 57 × 10-34 J s, but it has been a long road, and the trip is not over yet. Since its discovery as a fundamental physical constant to explain various effects in quantum theory, h has become especially important in defining standards for electrical measurements and soon, for mass determination. Measuring h in the International System of Units (SI) started as experimental attempts merely to prove its existence. Many decades passed while newer experiments measured physical effects that were the influence of h combined with other physical constants: elementary charge, e, and the Avogadro constant, NA. As experimental techniques improved, the precision of the value of h expanded. When the Josephson and quantum Hall theories led to new electronic devices, and a hundred year old experiment, the absolute ampere, was altered into a watt balance, h not only became vital in definitions for the volt and ohm units, but suddenly it could be measured directly and even more accurately. Finally, as measurement uncertainties now approach a few parts in 108 from the watt balance experiments and Avogadro determinations, its importance has been linked to a proposed redefinition of a kilogram unit of mass. The path to higher accuracy in measuring the value of h was not always an example of continuous progress. Since new measurements periodically led to changes in its accepted value and the corresponding SI units, it is helpful to see why there were bumps in the road and where the different branch lines of research joined in the effort. Recalling the bumps along this road will hopefully avoid their repetition in the upcoming SI redefinition debates. This paper begins with a brief history of the methods to measure a combination of fundamental constants, thus indirectly obtaining the Planck constant. The historical path is followed in the section describing how the improved

  2. A rapid and accurate method, ventilated chamber C-history method, of measuring the emission characteristic parameters of formaldehyde/VOCs in building materials.

    PubMed

    Huang, Shaodan; Xiong, Jianyin; Zhang, Yinping

    2013-10-15

    The indoor pollution caused by formaldehyde and volatile organic compounds (VOCs) emitted from building materials poses an adverse effect on people's health. It is necessary to understand and control the behaviors of the emission sources. Based on detailed mass transfer analysis on the emission process in a ventilated chamber, this paper proposes a novel method of measuring the three emission characteristic parameters, i.e., the initial emittable concentration, the diffusion coefficient and the partition coefficient. A linear correlation between the logarithm of dimensionless concentration and time is derived. The three parameters can then be calculated from the intercept and slope of the correlation. Compared with the closed chamber C-history method, the test is performed under ventilated condition thus some commonly-used measurement instruments (e.g., GC/MS, HPLC) can be applied. While compared with other methods, the present method can rapidly and accurately measure the three parameters, with experimental time less than 12h and R(2) ranging from 0.96 to 0.99 for the cases studied. Independent experiment was carried out to validate the developed method, and good agreement was observed between the simulations based on the determined parameters and experiments. The present method should prove useful for quick characterization of formaldehyde/VOC emissions from indoor materials. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Accurate measurements of carbon monoxide in humid air using the cavity ring-down spectroscopy (CRDS) technique

    NASA Astrophysics Data System (ADS)

    Chen, H.; Karion, A.; Rella, C. W.; Winderlich, J.; Gerbig, C.; Filges, A.; Newberger, T.; Sweeney, C.; Tans, P. P.

    2012-09-01

    Accurate measurements of carbon monoxide (CO) in humid air have been made using the cavity ring-down spectroscopy (CRDS) technique. The measurements of CO mole fractions are determined from the strength of its spectral absorption in the near infrared region (∼1.57 μm) after removing interferences from adjacent carbon dioxide (CO2) and water vapor (H2O) absorption lines. Water correction functions that account for the dilution and pressure-broadening effects as well as absorption line interferences from adjacent CO2 and H2O lines have been derived for CO2 mole fractions between 360-390 ppm. The line interference corrections are independent of CO mole fractions. The dependence of the line interference correction on CO2 abundance is estimated to be approximately -0.3 ppb/100 ppm CO2 for dry mole fractions of CO. Comparisons of water correction functions from different analyzers of the same type show significant differences, making it necessary to perform instrument-specific water tests for each individual analyzer. The CRDS analyzer was flown on an aircraft in Alaska from April to November in 2011, and the accuracy of the CO measurements by the CRDS analyzer has been validated against discrete NOAA/ESRL flask sample measurements made on board the same aircraft, with a mean difference between integrated in situ and flask measurements of -0.6 ppb and a standard deviation of 2.8 ppb. Preliminary testing of CRDS instrumentation that employs new spectroscopic analysis (available since the beginning of 2012) indicates a smaller water vapor dependence than the models discussed here, but more work is necessary to fully validate the performance. The CRDS technique provides an accurate and low-maintenance method of monitoring the atmospheric dry mole fractions of CO in humid air streams.

  4. Accurate and automatic extrinsic calibration method for blade measurement system integrated by different optical sensors

    NASA Astrophysics Data System (ADS)

    He, Wantao; Li, Zhongwei; Zhong, Kai; Shi, Yusheng; Zhao, Can; Cheng, Xu

    2014-11-01

    Fast and precise 3D inspection system is in great demand in modern manufacturing processes. At present, the available sensors have their own pros and cons, and hardly exist an omnipotent sensor to handle the complex inspection task in an accurate and effective way. The prevailing solution is integrating multiple sensors and taking advantages of their strengths. For obtaining a holistic 3D profile, the data from different sensors should be registrated into a coherent coordinate system. However, some complex shape objects own thin wall feather such as blades, the ICP registration method would become unstable. Therefore, it is very important to calibrate the extrinsic parameters of each sensor in the integrated measurement system. This paper proposed an accurate and automatic extrinsic parameter calibration method for blade measurement system integrated by different optical sensors. In this system, fringe projection sensor (FPS) and conoscopic holography sensor (CHS) is integrated into a multi-axis motion platform, and the sensors can be optimally move to any desired position at the object's surface. In order to simple the calibration process, a special calibration artifact is designed according to the characteristics of the two sensors. An automatic registration procedure based on correlation and segmentation is used to realize the artifact datasets obtaining by FPS and CHS rough alignment without any manual operation and data pro-processing, and then the Generalized Gauss-Markoff model is used to estimate the optimization transformation parameters. The experiments show the measurement result of a blade, where several sampled patches are merged into one point cloud, and it verifies the performance of the proposed method.

  5. Race/Ethnicity and Family Contact: Toward a Behavioral Measure of Familialism

    ERIC Educational Resources Information Center

    Comeau, Joseph A.

    2012-01-01

    Research from several disciplines has found that Latinos in the United States tend to score higher than other groups on measures of familialism. While most studies of Latino familialism use attitudinal measures rather than behavioral ones, I argue that examining behavioral measures of familialism can offer additional insights. This article…

  6. Accumulating Data to Optimally Predict Obesity Treatment (ADOPT) Core Measures: Behavioral Domain.

    PubMed

    Lytle, Leslie A; Nicastro, Holly L; Roberts, Susan B; Evans, Mary; Jakicic, John M; Laposky, Aaron D; Loria, Catherine M

    2018-04-01

    The ability to identify and measure behaviors that are related to weight loss and the prevention of weight regain is crucial to understanding the variability in response to obesity treatment and the development of tailored treatments. The overarching goal of the Accumulating Data to Optimally Predict obesity Treatment (ADOPT) Core Measures Project is to provide obesity researchers with guidance on a set of constructs and measures that are related to weight control and that span and integrate obesity-related behavioral, biological, environmental, and psychosocial domains. This article describes how the behavioral domain subgroup identified the initial list of high-priority constructs and measures to be included, and it describes practical considerations for assessing the following four behavioral areas: eating, activity, sleep, and self-monitoring of weight. Challenges and considerations for advancing the science related to weight loss and maintenance behaviors are also discussed. Assessing a set of core behavioral measures in combination with those from other ADOPT domains is critical to improve our understanding of individual variability in response to adult obesity treatment. The selection of behavioral measures is based on the current science, although there continues to be much work needed in this field. © 2018 The Obesity Society.

  7. Measuring implementation intentions in the context of the theory of planned behavior.

    PubMed

    Rise, Jostein; Thompson, Marianne; Verplanken, Bas

    2003-04-01

    The usefulness of measuring implementation intentions in the context of the theory of planned behavior (TPB) was explored among 112 Norwegian college students. They responded to a questionnaire measuring past behavior, perceived behavioral control, behavioral intentions, implementation intentions, and actual performance of regular exercising and recycling of drinking cartons. Implementation intentions were measured using five items relating to recycling and four items relating to exercise, which showed satisfactory internal consistencies. Consistent with the main prediction, the presence of implementation intentions was related to performing the two behaviors, although behavioral intentions were the strongest determinant for both behaviors. The results suggest that the TPB may benefit from inclusion of the concept of implementation intentions to provide a more complete understanding of the psychological process in which motivation is translated into action.

  8. Technical note: Instantaneous sampling intervals validated from continuous video observation for behavioral recording of feedlot lambs.

    PubMed

    Pullin, A N; Pairis-Garcia, M D; Campbell, B J; Campler, M R; Proudfoot, K L

    2017-11-01

    When considering methodologies for collecting behavioral data, continuous sampling provides the most complete and accurate data set whereas instantaneous sampling can provide similar results and also increase the efficiency of data collection. However, instantaneous time intervals require validation to ensure accurate estimation of the data. Therefore, the objective of this study was to validate scan sampling intervals for lambs housed in a feedlot environment. Feeding, lying, standing, drinking, locomotion, and oral manipulation were measured on 18 crossbred lambs housed in an indoor feedlot facility for 14 h (0600-2000 h). Data from continuous sampling were compared with data from instantaneous scan sampling intervals of 5, 10, 15, and 20 min using a linear regression analysis. Three criteria determined if a time interval accurately estimated behaviors: 1) ≥ 0.90, 2) slope not statistically different from 1 ( > 0.05), and 3) intercept not statistically different from 0 ( > 0.05). Estimations for lying behavior were accurate up to 20-min intervals, whereas feeding and standing behaviors were accurate only at 5-min intervals (i.e., met all 3 regression criteria). Drinking, locomotion, and oral manipulation demonstrated poor associations () for all tested intervals. The results from this study suggest that a 5-min instantaneous sampling interval will accurately estimate lying, feeding, and standing behaviors for lambs housed in a feedlot, whereas continuous sampling is recommended for the remaining behaviors. This methodology will contribute toward the efficiency, accuracy, and transparency of future behavioral data collection in lamb behavior research.

  9. Optimal neurocognitive, personality and behavioral measures for assessing impulsivity in cocaine dependence

    PubMed Central

    LoBue, Christian; Cullum, C. Munro; Braud, Jacqueline; Walker, Robrina; Winhusen, Theresa; Suderajan, Prabha; Adinoff, Bryon

    2015-01-01

    Background Impulsivity may underlie the poor treatment retention and high relapse rates observed in cocaine-dependent persons. However, observed differences in measures of impulsivity between cocaine-dependent and healthy control participants often do not reach clinical significance, suggesting that the clinical relevance of these differences may be limited. Objectives To examine which measures of impulsivity (i.e. self-report impulsivity, self-report personality, neurocognitive testing) best distinguish cocaine-dependent and healthy control participants (i.e. showing differences at least 1.5 standard deviations [SD] from controls). Optimal measures were considered to demonstrate sufficient classification accuracy. Methods Sixty-five recently abstinent cocaine-dependent and 25 healthy control participants were assessed using select neurocognitive tests and self-report questionnaires including the NEO Personality Inventory-Revised (NEO-PI-R), Temperament and Character Inventory (TCI), Barratt Impulsiveness Scale (BIS-11a), and the Frontal Systems Behavior Scale (FrSBe). Results When corrected for years of education and gender, neurocognitive measures did not demonstrate clinically significant differences between cocaine-dependent and control participants. The personality measures TCI Purposefulness and Congruent Second Nature and NEO-PI-R Impulsiveness, and the self-rating measures FrSBe Disinhibition and BIS-11 Motor Impulsivity and Total successfully identified clinically meaningful elevations in impulsivity within cocaine-dependent participants (>1.5 SDs from controls). Furthermore, these measures achieved 84–93% accuracy in discriminating cocaine-dependent from control participants. Conclusion Clinically significant neurocognitive impairment in cocaine-dependent participants was not observed in this sample. As the BIS-11 or FrSBe are brief to administer, accurate, and have been shown to predict treatment retention and relapse, these measures appear to be

  10. Development of Survey Scales for Measuring Exposure and Behavioral Responses to Disruptive Intraoperative Behavior.

    PubMed

    Villafranca, Alexander; Hamlin, Colin; Rodebaugh, Thomas L; Robinson, Sandra; Jacobsohn, Eric

    2017-09-10

    Disruptive intraoperative behavior has detrimental effects to clinicians, institutions, and patients. How clinicians respond to this behavior can either exacerbate or attenuate its effects. Previous investigations of disruptive behavior have used survey scales with significant limitations. The study objective was to develop appropriate scales to measure exposure and responses to disruptive behavior. We obtained ethics approval. The scales were developed in a sequence of steps. They were pretested using expert reviews, computational linguistic analysis, and cognitive interviews. The scales were then piloted on Canadian operating room clinicians. Factor analysis was applied to half of the data set for question reduction and grouping. Item response analysis and theoretical reviews ensured that important questions were not eliminated. Internal consistency was evaluated using Cronbach α. Model fit was examined on the second half of the data set using confirmatory factor analysis. Content validity of the final scales was re-evaluated. Consistency between observed relationships and theoretical predictions was assessed. Temporal stability was evaluated on a subsample of 38 respondents. A total of 1433 and 746 clinicians completed the exposure and response scales, respectively. Content validity indices were excellent (exposure = 0.96, responses = 1.0). Internal consistency was good (exposure = 0.93, responses = 0.87). Correlations between the exposure scale and secondary measures were consistent with expectations based on theory. Temporal stability was acceptable (exposure = 0.77, responses = 0.73). We have developed scales measuring exposure and responses to disruptive behavior. They generate valid and reliable scores when surveying operating room clinicians, and they overcome the limitations of previous tools. These survey scales are freely available.

  11. DEVELOPMENT AND VALIDATION OF A NEW SELF-REPORT MEASURE OF PAIN BEHAVIORS

    PubMed Central

    Cook, Karon F.; Keefe, Francis; Jensen, Mark P.; Roddey, Toni S.; Callahan, Leigh F.; Revicki, Dennis; Bamer, Alyssa M.; Kim, Jiseon; Chung, Hyewon; Salem, Rana; Amtmann, Dagmar

    2013-01-01

    Pain behaviors that are maintained beyond the acute stage post-injury can contribute to subsequent psychosocial and physical disability. Critical to the study of pain behaviors is the availability of psychometrically sound pain behavior measures. In this study we developed a self-report measure of pain behaviors, the Pain Behaviors Self Report (PaB-SR). PaB-SR scores were developed using item response theory and evaluated using a rigorous, multiple-witness approach to validity testing. Participants included: a) 661 survey participants with chronic pain and with multiple sclerosis (MS), back pain, or arthritis; b) 618 survey participants who were significant others of a chronic pain participant; and c) 86 participants in a videotaped pain behavior observation protocol. Scores on the PaB-SR were found to be measurement invariant with respect to clinical condition. PaB-SR scores, observer-reports, and the video-taped protocol yielded distinct, but convergent views of pain behavior, supporting the validity of the new measure. The PaB-SR is expected to be of substantial utility to researchers wishing to explore the relationship between pain behaviors and constructs such as pain intensity, pain interference, and disability. PMID:23994451

  12. History and progress on accurate measurements of the Planck constant.

    PubMed

    Steiner, Richard

    2013-01-01

    The measurement of the Planck constant, h, is entering a new phase. The CODATA 2010 recommended value is 6.626 069 57 × 10(-34) J s, but it has been a long road, and the trip is not over yet. Since its discovery as a fundamental physical constant to explain various effects in quantum theory, h has become especially important in defining standards for electrical measurements and soon, for mass determination. Measuring h in the International System of Units (SI) started as experimental attempts merely to prove its existence. Many decades passed while newer experiments measured physical effects that were the influence of h combined with other physical constants: elementary charge, e, and the Avogadro constant, N(A). As experimental techniques improved, the precision of the value of h expanded. When the Josephson and quantum Hall theories led to new electronic devices, and a hundred year old experiment, the absolute ampere, was altered into a watt balance, h not only became vital in definitions for the volt and ohm units, but suddenly it could be measured directly and even more accurately. Finally, as measurement uncertainties now approach a few parts in 10(8) from the watt balance experiments and Avogadro determinations, its importance has been linked to a proposed redefinition of a kilogram unit of mass. The path to higher accuracy in measuring the value of h was not always an example of continuous progress. Since new measurements periodically led to changes in its accepted value and the corresponding SI units, it is helpful to see why there were bumps in the road and where the different branch lines of research joined in the effort. Recalling the bumps along this road will hopefully avoid their repetition in the upcoming SI redefinition debates. This paper begins with a brief history of the methods to measure a combination of fundamental constants, thus indirectly obtaining the Planck constant. The historical path is followed in the section describing how the

  13. Measurement of Motivations for and against Sexual Behavior

    ERIC Educational Resources Information Center

    Patrick, Megan E.; Maggs, Jennifer L.; Cooper, M. Lynne; Lee, Christine M.

    2011-01-01

    A multidimensional measure assessing distinct motivations for and against sex was shown to be reliable, valid, and configurally invariant among incoming first-year college students. Three Motivations Against Sex Questionnaire subscales were developed to measure motivations "against" sexual behavior (Values, Health, Not Ready) to complement and…

  14. Can Wearable Devices Accurately Measure Heart Rate Variability? A Systematic Review.

    PubMed

    Georgiou, Konstantinos; Larentzakis, Andreas V; Khamis, Nehal N; Alsuhaibani, Ghadah I; Alaska, Yasser A; Giallafos, Elias J

    2018-03-01

    A growing number of wearable devices claim to provide accurate, cheap and easily applicable heart rate variability (HRV) indices. This is mainly accomplished by using wearable photoplethysmography (PPG) and/or electrocardiography (ECG), through simple and non-invasive techniques, as a substitute of the gold standard RR interval estimation through electrocardiogram. Although the agreement between pulse rate variability (PRV) and HRV has been evaluated in the literature, the reported results are still inconclusive especially when using wearable devices. The purpose of this systematic review is to investigate if wearable devices provide a reliable and precise measurement of classic HRV parameters in rest as well as during exercise. A search strategy was implemented to retrieve relevant articles from MEDLINE and SCOPUS databases, as well as, through internet search. The 308 articles retrieved were reviewed for further evaluation according to the predetermined inclusion/exclusion criteria. Eighteen studies were included. Sixteen of them integrated ECG - HRV technology and two of them PPG - PRV technology. All of them examined wearable devices accuracy in RV detection during rest, while only eight of them during exercise. The correlation between classic ECG derived HRV and the wearable RV ranged from very good to excellent during rest, yet it declined progressively as exercise level increased. Wearable devices may provide a promising alternative solution for measuring RV. However, more robust studies in non-stationary conditions are needed using appropriate methodology in terms of number of subjects involved, acquisition and analysis techniques implied.

  15. Measuring radio-signal power accurately

    NASA Technical Reports Server (NTRS)

    Goldstein, R. M.; Newton, J. W.; Winkelstein, R. A.

    1979-01-01

    Absolute value of signal power in weak radio signals is determined by computer-aided measurements. Equipment operates by averaging received signal over several-minute period and comparing average value with noise level of receiver previously calibrated.

  16. Non-destructive testing principles and accurate evaluation of the hydraulic measure impact range using the DC method

    NASA Astrophysics Data System (ADS)

    Qiu, Liming; Shen, Rongxi; Song, Dazhao; Wang, Enyuan; Liu, Zhentang; Niu, Yue; Jia, Haishan; Xia, Shankui; Zheng, Xiangxin

    2017-12-01

    An accurate and non-destructive evaluation method for the hydraulic measure impact range in coal seams is urgently needed. Aiming at the application demands, a theoretical study and field test are presented using the direct current (DC) method to evaluate the impact range of coal seam hydraulic measures. We firstly analyzed the law of the apparent resistivity response of an abnormal conductive zone in a coal seam, and then investigated the principle of non-destructive testing of the coal seam hydraulic measure impact range using the DC method, and used an accurate evaluation method based on the apparent resistivity cloud chart. Finally, taking hydraulic fracturing and hydraulic flushing as examples, field experiments were carried out in coal mines to evaluate the impact ranges. The results showed that: (1) in the process of hydraulic fracturing, coal conductivity was enhanced by high-pressure water in the coal seam, and after hydraulic fracturing, the boundary of the apparent resistivity decrease area was the boundary impact range. (2) In the process of hydraulic flushing, coal conductivity was reduced by holes and cracks in the coal seam, and after hydraulic flushing, the boundary of the apparent resistivity increase area was the boundary impact range. (3) After the implementation of the hydraulic measures, there may be some blind zones in the coal seam; in hydraulic fracturing blind zones, the apparent resistivity increased or stayed constant, while in hydraulic flushing blind zones, the apparent resistivity decreased or stayed constant. The DC method realized a comprehensive and non-destructive evaluation of the impact range of the hydraulic measures, and greatly reduced the time and cost of evaluation.

  17. Object strength--an accurate measure for small objects that is insensitive to partial volume effects.

    PubMed

    Tofts, P S; Silver, N C; Barker, G J; Gass, A

    2005-07-01

    There are currently four problems in characterising small nonuniform lesions or other objects in Magnetic Resonance images where partial volume effects are significant. Object size is over- or under-estimated; boundaries are often not reproducible; mean object value cannot be measured; and fuzzy borders cannot be accommodated. A new measure, Object Strength, is proposed. This is the sum of all abnormal intensities, above a uniform background value. For a uniform object, this is simply the product of the increase in intensity and the size of the object. Biologically, this could be at least as relevant as existing measures of size or mean intensity. We hypothesise that Object Strength will perform better than traditional area measurements in characterising small objects. In a pilot study, the reproducibility of object strength measurements was investigated using MR images of small multiple sclerosis (MS) lesions. In addition, accuracy was investigated using artificial lesions of known volume (0.3-6.2 ml) and realistic appearance. Reproducibility approached that of area measurements (in 33/90 lesion reports the difference between repeats was less than for area measurements). Total lesion volume was accurate to 0.2%. In conclusion, Object Strength has potential for improved characterisation of small lesions and objects in imaging and possibly spectroscopy.

  18. Accurate measurement of heteronuclear dipolar couplings by phase-alternating R-symmetry (PARS) sequences in magic angle spinning NMR spectroscopy

    NASA Astrophysics Data System (ADS)

    Hou, Guangjin; Lu, Xingyu; Vega, Alexander J.; Polenova, Tatyana

    2014-09-01

    We report a Phase-Alternating R-Symmetry (PARS) dipolar recoupling scheme for accurate measurement of heteronuclear 1H-X (X = 13C, 15N, 31P, etc.) dipolar couplings in MAS NMR experiments. It is an improvement of conventional C- and R-symmetry type DIPSHIFT experiments where, in addition to the dipolar interaction, the 1H CSA interaction persists and thereby introduces considerable errors in the dipolar measurements. In PARS, phase-shifted RN symmetry pulse blocks applied on the 1H spins combined with π pulses applied on the X spins at the end of each RN block efficiently suppress the effect from 1H chemical shift anisotropy, while keeping the 1H-X dipolar couplings intact. Another advantage over conventional DIPSHIFT experiments, which require the signal to be detected in the form of a reduced-intensity Hahn echo, is that the series of π pulses refocuses the X chemical shift and avoids the necessity of echo formation. PARS permits determination of accurate dipolar couplings in a single experiment; it is suitable for a wide range of MAS conditions including both slow and fast MAS frequencies; and it assures dipolar truncation from the remote protons. The performance of PARS is tested on two model systems, [15N]-N-acetyl-valine and [U-13C,15N]-N-formyl-Met-Leu-Phe tripeptide. The application of PARS for site-resolved measurement of accurate 1H-15N dipolar couplings in the context of 3D experiments is presented on U-13C,15N-enriched dynein light chain protein LC8.

  19. Analysis of Behavioral Indicators as a Measure of Satiation.

    PubMed

    Scalzo, Rachel; Davis, Tonya N

    2017-03-01

    Providing noncontingent access to a stimulus until an individual displays behavioral indicators of satiation has been used to determine when an abolishing operation is in effect, but there has been variation in its application in the literature. Four males diagnosed with autism spectrum disorder with tangibly maintained challenging behavior participated in this study. Individualized behavioral indicators were identified and verified to determine when each participant was finished playing with his/her preferred item. Three presession conditions were manipulated including restricted access to the tangible stimulus for 30 min, access to the tangible stimulus until the display of one behavioral indicator, and access to the tangible stimulus until the display of three behavioral indicators. Each presession condition was followed by a tangible condition of the functional analysis to measure challenging behavior. Results indicated that presession access to a tangible stimulus until the display of three behavioral indicators produced a greater abative effect on challenging behavior than one behavioral indicator.

  20. Social Desirability Responding in the Measurement of Assertive Behavior.

    ERIC Educational Resources Information Center

    Kiecolt, Janice; McGrath, Ellen

    1979-01-01

    Women completed behavioral measures of assertion and anxiety before and after assertiveness training. High social desirability scorers described themselves as more assertive and less anxious, but were behaviorally less assertive than low scorers. Although all scorers improved their assertion skills, high scorers did not appear less anxious after…

  1. Development and validation of a new self-report measure of pain behaviors.

    PubMed

    Cook, Karon F; Keefe, Francis; Jensen, Mark P; Roddey, Toni S; Callahan, Leigh F; Revicki, Dennis; Bamer, Alyssa M; Kim, Jiseon; Chung, Hyewon; Salem, Rana; Amtmann, Dagmar

    2013-12-01

    Pain behaviors that are maintained beyond the acute stage after injury can contribute to subsequent psychosocial and physical disability. Critical to the study of pain behaviors is the availability of psychometrically sound pain behavior measures. In this study we developed a self-report measure of pain behaviors, the Pain Behaviors Self Report (PaB-SR). PaB-SR scores were developed using item response theory and evaluated using a rigorous, multiple-witness approach to validity testing. Participants included 661 survey participants with chronic pain and with multiple sclerosis, back pain, or arthritis; 618 survey participants who were significant others of a chronic pain participant; and 86 participants in a videotaped pain behavior observation protocol. Scores on the PaB-SR were found to be measurement invariant with respect to clinical condition. PaB-SR scores, observer reports, and the videotaped protocol yielded distinct, but convergent views of pain behavior, supporting the validity of the new measure. The PaB-SR is expected to be of substantial utility to researchers wishing to explore the relationship between pain behaviors and constructs such as pain intensity, pain interference, and disability. Copyright © 2013 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  2. Observed Parenting Behavior with Teens: Measurement Invariance and Predictive Validity Across Race

    PubMed Central

    Skinner, Martie L.; MacKenzie, Elizabeth P.; Haggerty, Kevin P.; Hill, Karl G.; Roberson, Kendra C.

    2011-01-01

    Previous reports supporting measurement equality between European American and African American families have often focused on self-reported risk factors or observed parent behavior with young children. This study examines equality of measurement of observer ratings of parenting behavior with adolescents during structured tasks; mean levels of observed parenting; and predictive validity of teen self-reports of antisocial behaviors and beliefs using a sample of 163 African American and 168 European American families. Multiple-group confirmatory factor analyses supported measurement invariance across ethnic groups for 4 measures of observed parenting behavior: prosocial rewards, psychological costs, antisocial rewards, and problem solving. Some mean-level differences were found: African American parents exhibited lower levels of prosocial rewards, higher levels of psychological costs, and lower problem solving when compared to European Americans. No significant mean difference was found in rewards for antisocial behavior. Multigroup structural equation models suggested comparable relationships across race (predictive validity) between parenting constructs and youth antisocial constructs (i.e., drug initiation, positive drug attitudes, antisocial attitudes, problem behaviors) in all but one of the tested relationships. This study adds to existing evidence that family-based interventions targeting parenting behaviors can be generalized to African American families. PMID:21787057

  3. Measuring Iranian women's sexual behaviors: Expert opinion

    PubMed Central

    Ghorashi, Zohreh; Merghati-Khoei, Effat; Yousefy, Alireza

    2014-01-01

    The cultural compatibility of sexually related instruments is problematic because the contexts from which the concepts and meanings were extracted may be significantly different from related contexts in a different society. This paper describes the instruments that have been used to assess sexual behaviors, primarily in Western contexts. Then, based on the instruments’ working definition of ‘sexual behavior’ and their theoretical frameworks, we will (1) discuss the applicability or cultural compatibility of existing instruments targeting women's sexual behaviors within an Iranian context, and (2) suggest criteria for sexually related tools applicable in Iranian settings. Iranian women's sexual scripts may compromise the existing instruments’ compatibility. Suggested criteria are as follows: understanding, language of sexuality, ethics and morality. Therefore, developing a culturally comprehensive measure that can adequately examine Iranian women's sexual behaviors is needed. PMID:25250346

  4. Development of a Behaviorally Anchored Rating Scale for Leadership

    DTIC Science & Technology

    2018-01-01

    Research Product 2018-06 Development of a Behaviorally Anchored Rating Scale for Leadership Tatiana H. Toumbeva Krista L...anchored Rating Scale for Leadership 5a. CONTRACT NUMBER W5J9CQ-11-D-0004 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 62278 6...observer- based behavioral measure to help instructors more reliably and accurately evaluate the development of leadership attributes and competencies

  5. Accurate quantitation standards of glutathione via traceable sulfur measurement by inductively coupled plasma optical emission spectrometry and ion chromatography

    PubMed Central

    Rastogi, L.; Dash, K.; Arunachalam, J.

    2013-01-01

    The quantitative analysis of glutathione (GSH) is important in different fields like medicine, biology, and biotechnology. Accurate quantitative measurements of this analyte have been hampered by the lack of well characterized reference standards. The proposed procedure is intended to provide an accurate and definitive method for the quantitation of GSH for reference measurements. Measurement of the stoichiometrically existing sulfur content in purified GSH offers an approach for its quantitation and calibration through an appropriate characterized reference material (CRM) for sulfur would provide a methodology for the certification of GSH quantity, that is traceable to SI (International system of units). The inductively coupled plasma optical emission spectrometry (ICP-OES) approach negates the need for any sample digestion. The sulfur content of the purified GSH is quantitatively converted into sulfate ions by microwave-assisted UV digestion in the presence of hydrogen peroxide prior to ion chromatography (IC) measurements. The measurement of sulfur by ICP-OES and IC (as sulfate) using the “high performance” methodology could be useful for characterizing primary calibration standards and certified reference materials with low uncertainties. The relative expanded uncertainties (% U) expressed at 95% confidence interval for ICP-OES analyses varied from 0.1% to 0.3%, while in the case of IC, they were between 0.2% and 1.2%. The described methods are more suitable for characterizing primary calibration standards and certifying reference materials of GSH, than for routine measurements. PMID:29403814

  6. Teaching Behavior and Well-Being in Students: Development and Concurrent Validity of an Instrument to Measure Student-Reported Teaching Behavior

    ERIC Educational Resources Information Center

    Pössel, Patrick; Moritz Rudasill, Kathleen; Adelson, Jill L.; Bjerg, Annie C.; Wooldridge, Don T.; Black, Stephanie Winkeljohn

    2013-01-01

    Teaching behavior has important implications for students' emotional well-being. Multiple models suggest students' perceptions of teaching behaviors are more critical than other measures for predicting well-being, yet student-report instruments that measure concrete and specific teaching behavior are limited. The purpose of the present studies is…

  7. Accurate measurements of carbon monoxide in humid air using the cavity ring-down spectroscopy (CRDS) technique

    NASA Astrophysics Data System (ADS)

    Chen, H.; Karion, A.; Rella, C. W.; Winderlich, J.; Gerbig, C.; Filges, A.; Newberger, T.; Sweeney, C.; Tans, P. P.

    2013-04-01

    Accurate measurements of carbon monoxide (CO) in humid air have been made using the cavity ring-down spectroscopy (CRDS) technique. The measurements of CO mole fractions are determined from the strength of its spectral absorption in the near-infrared region (~1.57 μm) after removing interferences from adjacent carbon dioxide (CO2) and water vapor (H2O) absorption lines. Water correction functions that account for the dilution and pressure-broadening effects as well as absorption line interferences from adjacent CO2 and H2O lines have been derived for CO2 mole fractions between 360-390 ppm and for reported H2O mole fractions between 0-4%. The line interference corrections are independent of CO mole fractions. The dependence of the line interference correction on CO2 abundance is estimated to be approximately -0.3 ppb/100 ppm CO2 for dry mole fractions of CO. Comparisons of water correction functions from different analyzers of the same type show significant differences, making it necessary to perform instrument-specific water tests for each individual analyzer. The CRDS analyzer was flown on an aircraft in Alaska from April to November in 2011, and the accuracy of the CO measurements by the CRDS analyzer has been validated against discrete NOAA/ESRL flask sample measurements made on board the same aircraft, with a mean difference between integrated in situ and flask measurements of -0.6 ppb and a standard deviation of 2.8 ppb. Preliminary testing of CRDS instrumentation that employs improved spectroscopic model functions for CO2, H2O, and CO to fit the raw spectral data (available since the beginning of 2012) indicates a smaller water vapor dependence than the models discussed here, but more work is necessary to fully validate the performance. The CRDS technique provides an accurate and low-maintenance method of monitoring the atmospheric dry mole fractions of CO in humid air streams.

  8. Home Circadian Phase Assessments with Measures of Compliance Yield Accurate Dim Light Melatonin Onsets.

    PubMed

    Burgess, Helen J; Wyatt, James K; Park, Margaret; Fogg, Louis F

    2015-06-01

    There is a need for the accurate assessment of circadian phase outside of the clinic/laboratory, particularly with the gold standard dim light melatonin onset (DLMO). We tested a novel kit designed to assist in saliva sampling at home for later determination of the DLMO. The home kit includes objective measures of compliance to the requirements for dim light and half-hourly saliva sampling. Participants were randomized to one of two 10-day protocols. Each protocol consisted of two back-to-back home and laboratory phase assessments in counterbalanced order, separated by a 5-day break. Laboratory or participants' homes. Thirty-five healthy adults, age 21-62 y. N/A. Most participants received at least one 30-sec epoch of light > 50 lux during the home phase assessments (average light intensity 4.5 lux), but on average for < 9 min of the required 8.5 h. Most participants collected every saliva sample within 5 min of the scheduled time. Ninety-two percent of home DLMOs were not affected by light > 50 lux or sampling errors. There was no significant difference between the home and laboratory DLMOs (P > 0.05); on average the home DLMOs occurred 9.6 min before the laboratory DLMOs. The home DLMOs were highly correlated with the laboratory DLMOs (r = 0.91, P < 0.001). Participants were reasonably compliant to the home phase assessment procedures. The good agreement between the home and laboratory dim light melatonin onsets (DLMOs) demonstrates that including objective measures of light exposure and sample timing during home saliva sampling can lead to accurate home DLMOs. Circadian Phase Assessments at Home, http://clinicaltrials.gov/show/NCT01487252, NCT01487252. © 2015 Associated Professional Sleep Societies, LLC.

  9. Detecting Children's Lies: Are Parents Accurate Judges of Their Own Children's Lies?

    ERIC Educational Resources Information Center

    Talwar, Victoria; Renaud, Sarah-Jane; Conway, Lauryn

    2015-01-01

    The current study investigated whether parents are accurate judges of their own children's lie-telling behavior. Participants included 250 mother-child dyads. Children were between three and 11 years of age. A temptation resistance paradigm was used to elicit a minor transgressive behavior from the children involving peeking at a forbidden toy and…

  10. Milieu matters: Evidence that ongoing lifestyle activities influence health behaviors

    PubMed Central

    Lowe, Rob; Norman, Paul

    2017-01-01

    Health behaviors occur within a milieu of lifestyle activities that could conflict with health actions. We examined whether cognitions about, and performance of, other lifestyle activities augment the prediction of health behaviors, and whether these lifestyle factors are especially influential among individuals with low health behavior engagement. Participants (N = 211) completed measures of past behavior and cognitions relating to five health behaviors (e.g., smoking, getting drunk) and 23 lifestyle activities (e.g., reading, socializing), as well as personality variables. All behaviors were measured again at two weeks. Data were analyzed using neural network and cluster analyses. The neural network accurately predicted health behaviors at follow-up (R2 = .71). As hypothesized, lifestyle cognitions and activities independently predicted health behaviors over and above behavior-specific cognitions and previous behavior. Additionally, lifestyle activities and poor self-regulatory capability were more influential among people exhibiting unhealthy behaviors. Considering ongoing lifestyle activities can enhance prediction and understanding of health behaviors and offer new targets for health behavior interventions. PMID:28662120

  11. Laser diode absorption spectroscopy for accurate CO(2) line parameters at 2 microm: consequences for space-based DIAL measurements and potential biases.

    PubMed

    Joly, Lilian; Marnas, Fabien; Gibert, Fabien; Bruneau, Didier; Grouiez, Bruno; Flamant, Pierre H; Durry, Georges; Dumelie, Nicolas; Parvitte, Bertrand; Zéninari, Virginie

    2009-10-10

    Space-based active sensing of CO(2) concentration is a very promising technique for the derivation of CO(2) surface fluxes. There is a need for accurate spectroscopic parameters to enable accurate space-based measurements to address global climatic issues. New spectroscopic measurements using laser diode absorption spectroscopy are presented for the preselected R30 CO(2) absorption line ((20(0)1)(III)<--(000) band) and four others. The line strength, air-broadening halfwidth, and its temperature dependence have been investigated. The results exhibit significant improvement for the R30 CO(2) absorption line: 0.4% on the line strength, 0.15% on the air-broadening coefficient, and 0.45% on its temperature dependence. Analysis of potential biases of space-based DIAL CO(2) mixing ratio measurements associated to spectroscopic parameter uncertainties are presented.

  12. Accurate measurement of dispersion data through short and narrow tubes used in very high-pressure liquid chromatography.

    PubMed

    Gritti, Fabrice; McDonald, Thomas; Gilar, Martin

    2015-09-04

    An original method is proposed for the accurate and reproducible measurement of the time-based dispersion properties of short L< 50cm and narrow rc< 50μm tubes at mobile phase flow rates typically used in very high-pressure liquid chromatography (vHPLC). Such tubes are used to minimize sample dispersion in vHPLC; however, their dispersion characteristics cannot be accurately measured at such flow rates due to system dispersion contribution of vHPLC injector and detector. It is shown that using longer and wider tubes (>10μL) enables a reliable measurement of the dispersion data. We confirmed that the dimensionless plot of the reduced dispersion coefficient versus the reduced linear velocity (Peclet number) depends on the aspect ratio, L/rc, of the tube, and unexpectedly also on the diffusion coefficient of the analyte. This dimensionless plot could be easily obtained for a large volume tube, which has the same aspect ratio as that of the short and narrow tube, and for the same diffusion coefficient. The dispersion data for the small volume tube are then directly extrapolated from this plot. For instance, it is found that the maximum volume variances of 75μm×30.5cm and 100μm×30.5cm prototype finger-tightened connecting tubes are 0.10 and 0.30μL(2), respectively, with an accuracy of a few percent and a precision smaller than seven percent. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Radio interferometric measurements for accurate planetary orbiter navigation

    NASA Technical Reports Server (NTRS)

    Poole, S. R.; Ananda, M.; Hildebrand, C. E.

    1979-01-01

    The use of narrowband delta-VLBI to achieve accurate orbit determination is presented by viewing a spacecraft from widely separated stations followed by viewing a nearby quasar from the same stations. Current analysis is examined that establishes the orbit determination accuracy achieved with data arcs spanning up to 3.5 d. Strategies for improving prediction accuracy are given, and the performance of delta-VLBI is compared with conventional radiometric tracking data. It is found that accuracy 'within the fit' is on the order of 0.5 km for data arcs having delta-VLBI on the ends of the arcs and for arc lengths varying from one baseline to 3.5 d. The technique is discussed with reference to the proposed Venus Orbiting Imaging Radar mission.

  14. Revisit to three-dimensional percolation theory: Accurate analysis for highly stretchable conductive composite materials

    PubMed Central

    Kim, Sangwoo; Choi, Seongdae; Oh, Eunho; Byun, Junghwan; Kim, Hyunjong; Lee, Byeongmoon; Lee, Seunghwan; Hong, Yongtaek

    2016-01-01

    A percolation theory based on variation of conductive filler fraction has been widely used to explain the behavior of conductive composite materials under both small and large deformation conditions. However, it typically fails in properly analyzing the materials under the large deformation since the assumption may not be valid in such a case. Therefore, we proposed a new three-dimensional percolation theory by considering three key factors: nonlinear elasticity, precisely measured strain-dependent Poisson’s ratio, and strain-dependent percolation threshold. Digital image correlation (DIC) method was used to determine actual Poisson’s ratios at various strain levels, which were used to accurately estimate variation of conductive filler volume fraction under deformation. We also adopted strain-dependent percolation threshold caused by the filler re-location with deformation. When three key factors were considered, electrical performance change was accurately analyzed for composite materials with both isotropic and anisotropic mechanical properties. PMID:27694856

  15. The need for accurate total cholesterol measurement. Recommended analytical goals, current state of reliability, and guidelines for better determinations.

    PubMed

    Naito, H K

    1989-03-01

    We have approached a dawn of a new era in detection, evaluation, treatment, and monitoring of individuals with elevated blood cholesterol levels who are at increased risk for CHD. The NHLBI's National Cholesterol Education Program will be the major force underlying this national awareness program, which is dependent on the clinical laboratories providing reliable data. Precision or reproducibility of results is not a problem for most of the laboratories, but accuracy is a major concern. Both the manufacturers and laboratorians need to standardize the measurement for cholesterol so that the accuracy base is traceable to the NCCLS NRS/CHOL. The manufacturers need to adopt a uniform policy that will ensure that the values assigned to calibration, quality control, and quality assurance or survey materials are accurate and traceable to the NCCLS/CHOL. Since, at present, there are some limitations of these materials caused by matrix effects, laboratories are encouraged to use the CDC-NHLBI National Reference Laboratory Network to evaluate and monitor their ability to measure patient blood cholesterol levels accurately. Major areas of analytical problems are identified and general, as well as specific, recommendations are provided to help ensure reliable measurement of cholesterol in patient specimens.

  16. The Child Play Behavior and Activity Questionnaire: A Parent-Report Measure of Childhood Gender-Related Behavior in China

    PubMed Central

    Winter, Sam; Xie, Dong

    2008-01-01

    Boys and girls establish relatively stable gender stereotyped behavior patterns by middle childhood. Parent-report questionnaires measuring children’s gender-related behavior enable researchers to conduct large-scale screenings of community samples of children. For school-aged children, two parent-report instruments, the Child Game Participation Questionnaire (CGPQ) and the Child Behavior and Attitude Questionnaire (CBAQ), have long been used for measuring children’s sex-dimorphic behaviors in Western societies, but few studies have been conducted using these measures for Chinese populations. The current study aimed to empirically examine and modify the two instruments for their applications to Chinese society. Parents of 486 Chinese boys and 417 Chinese girls (6–12 years old) completed a questionnaire comprising items from the CGPQ and CBAQ, and an additional 14 items specifically related to Chinese gender-specific games. Items revealing gender differences in a Chinese sample were identified and used to construct a Child Play Behavior and Activity Questionnaire (CPBAQ). Four new scales were generated through factor analysis: a Gender Scale, a Girl Typicality Scale, a Boy Typicality Scale, and a Cross-Gender Scale (CGS). These scales had satisfactory internal reliabilities and large effect sizes for gender. The CPBAQ is believed to be a promising instrument for measuring children’s gender-related behavior in China. PMID:18719986

  17. Venous Thromboembolism Quality Measures Fail to Accurately Measure Quality.

    PubMed

    Lau, Brandyn D; Streiff, Michael B; Pronovost, Peter J; Haut, Elliott R

    2018-03-20

    Venous thromboembolism (VTE) is 1 of the most common causes of preventable harm for patients in hospitals. Consequently, the Joint Commission, the Centers for Medicare and Medicaid Services, the Agency for Healthcare Research and Quality, the United Kingdom Care Quality Commission, the Australian Commission on Safety and Quality in Health Care, the Maryland Health Services Cost Review Commission, and the American College of Surgeons have prioritized measuring and reporting VTE outcomes with the goal of reducing the incidence of and preventable harm from VTE. We developed a rubric for defect-free VTE prevention, graded each organizational VTE quality measure, and found that none of the current VTE-related quality measures adequately characterizes VTE prevention efforts or outcomes in hospitalized patients. Effective VTE prevention is multifactorial: clinicians must assess patients' risk for VTE and prescribe therapy appropriate for each patient's risk profile, patients must accept the prescribed therapy, and nurses must administer the therapy as prescribed. First, an ideal, defect-free VTE prevention process measure requires: (1) documentation of a standardized VTE risk assessment; (2) prescription of optimal, risk-appropriate VTE prophylaxis; and (3) administration of all risk-appropriate VTE prophylaxis as prescribed. Second, an ideal VTE outcome measure should define potentially preventable VTE as VTE that developed in patients who experienced any VTE prevention process failures. © 2018 American Heart Association, Inc.

  18. Accurate and cost-effective MTF measurement system for lens modules of digital cameras

    NASA Astrophysics Data System (ADS)

    Chang, Gao-Wei; Liao, Chia-Cheng; Yeh, Zong-Mu

    2007-01-01

    For many years, the widening use of digital imaging products, e.g., digital cameras, has given rise to much attention in the market of consumer electronics. However, it is important to measure and enhance the imaging performance of the digital ones, compared to that of conventional cameras (with photographic films). For example, the effect of diffraction arising from the miniaturization of the optical modules tends to decrease the image resolution. As a figure of merit, modulation transfer function (MTF) has been broadly employed to estimate the image quality. Therefore, the objective of this paper is to design and implement an accurate and cost-effective MTF measurement system for the digital camera. Once the MTF of the sensor array is provided, that of the optical module can be then obtained. In this approach, a spatial light modulator (SLM) is employed to modulate the spatial frequency of light emitted from the light-source. The modulated light going through the camera under test is consecutively detected by the sensors. The corresponding images formed from the camera are acquired by a computer and then, they are processed by an algorithm for computing the MTF. Finally, through the investigation on the measurement accuracy from various methods, such as from bar-target and spread-function methods, it appears that our approach gives quite satisfactory results.

  19. Validation of the Elementary Social Behavior Assessment: A Measure of Student Prosocial School Behaviors

    ERIC Educational Resources Information Center

    Pennefather, Jordan T.; Smolkowski, Keith

    2015-01-01

    We describe the psychometric evaluation of the "Elementary Social Behavior Assessment" (ESBA™), a 12-item scale measuring teacher-preferred, positive social skills. The ESBA was developed for use in elementary school classrooms to measure teacher perceptions of students using time-efficient, web-based data collection methods that allow…

  20. Interrelating Behavioral Measures of Distress Tolerance with Self-Reported Experiential Avoidance.

    PubMed

    Schloss, Heather M; Haaga, David A F

    2011-03-01

    Experiential avoidance and distress intolerance play a central role in novel behavior therapies, yet they appear to overlap considerably the REBT concept of low frustration tolerance. Using baseline data from 100 adult cigarette smokers enrolled in a clinical trial of smoking cessation therapies, the present study evaluated the convergent validity of common questionnaire measures of experiential avoidance (Acceptance and Action Questionnaire; AAQ; Hayes et al. 2004, and Avoidance and Inflexibility Scale: AIS; Gifford et al. 2004) and behavioral measures of distress tolerance (computerized Mirror Tracing Persistence Task: MTPT-C: Strong et al. 2003; computerized Paced Auditory Serial Addition Task; PASAT-C; Lejuez et al. 2003). The distress tolerance measures correlated significantly (r = .29) with one another. However, the questionnaire measures of experiential avoidance did not correlate with each other, nor with the behavioral measures. Further research is needed on the validity of measuring experiential avoidance by self-report and of the overlap versus distinctiveness of seemingly similar constructs such as experiential avoidance, distress tolerance, and frustration tolerance.

  1. Z-scan theoretical and experimental studies for accurate measurements of the nonlinear refractive index and absorption of optical glasses near damage threshold

    NASA Astrophysics Data System (ADS)

    Olivier, Thomas; Billard, Franck; Akhouayri, Hassan

    2004-06-01

    Self-focusing is one of the dramatic phenomena that may occur during the propagation of a high power laser beam in a nonlinear material. This phenomenon leads to a degradation of the wave front and may also lead to a photoinduced damage of the material. Realistic simulations of the propagation of high power laser beams require an accurate knowledge of the nonlinear refractive index γ. In the particular case of fused silica and in the nanosecond regime, it seems that electronic mechanisms as well as electrostriction and thermal effects can lead to a significant refractive index variation. Compared to the different methods used to measure this parmeter, the Z-scan method is simple, offers a good sensitivity and may give absolute measurements if the incident beam is accurately studied. However, this method requires a very good knowledge of the incident beam and of its propagation inside a nonlinear sample. We used a split-step propagation algorithm to simlate Z-scan curves for arbitrary beam shape, sample thickness and nonlinear phase shift. According to our simulations and a rigorous analysis of the Z-scan measured signal, it appears that some abusive approximations lead to very important errors. Thus, by reducing possible errors on the interpretation of Z-scan experimental studies, we performed accurate measurements of the nonlinear refractive index of fused silica that show the significant contribution of nanosecond mechanisms.

  2. Measuring behavior in mice with chronic stress depression paradigm.

    PubMed

    Strekalova, Tatyana; Steinbusch, Harry W M

    2010-03-17

    Many studies with chronic stress, a common depression paradigm, lead to inconsistent behavioral results. We are introducing a new model of stress-induced anhedonia, which provides more reproducible induction and behavioral measuring of depressive-like phenotype in mice. First, a 4-week stress procedure induces anhedonia, defined by decreased sucrose preference, in the majority of but not all C57BL/6 mice. The remaining 30-50% non-anhedonic animals are used as an internal control for stress effects that are unrelated to anhedonia. Next, a modified sucrose test enables the detection of inter-individual differences in mice. Moreover, testing under dimmed lighting precludes behavioral artifacts caused by hyperlocomotion, a major confounding factor in stressed mice. Finally, moderation of the stress load increases the reproducibility of anhedonia induction, which otherwise is difficult to provide because of inter-batch variability in laboratory mice. We believe that our new mouse model overcomes some major difficulties in measuring behavior with chronic stress depression models. Copyright 2009 Elsevier Inc. All rights reserved.

  3. Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode.

    PubMed

    Omar, Mohamed; Sarkissian, Carl; Jianbo, Li; Calle, Juan; Monga, Manoj

    2016-01-01

    To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recente pH result measured by dipstick from a spot urine sample that preceded the result of a 24-hour urine pH measured by the use of a pH electrode. Patients were excluded if there was a change in medications or dietary recommendations or if the two samples were more than 4 months apart. A difference of more than 0.5 pH was considered na inaccurate result. A total 600 patients were retrospectively reviewed for the pH results. The mean difference in pH between spot urine value and the 24 hours collection values was 0.52±0.45 pH. Higher pH was associated with lower accuracy (p<0.001). The accuracy of spot urine samples to predict 24-hour pH values of <5.5 was 68.9%, 68.2% for 5.5 to 6.5 and 35% for >6.5. Samples taken more than 75 days apart had only 49% the accuracy of more recent samples (p<0.002). The overall accuracy is lower than 80% (p<0.001). Influence of diurnal variation was not significant (p=0.588). Spot urine pH by dipstick is not an accurate method for evaluation of the patients with urolithiasis. Patients with alkaline urine are more prone to error with reliance on spot urine pH.

  4. Anisotropic Thermal Behavior of Silicone Polymer, DC 745

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adams, Jillian Cathleen; Torres, Joseph Angelo; Volz, Heather Michelle

    In material applications, it is important to understand how polymeric materials behave in the various environments they may encounter. One factor governing polymer behavior is processing history. Differences in fabrication will result in parts with varied or even unintended properties. In this work, the thermal expansion behavior of silicone DC 745 is studied. Thermomechanical analysis (TMA) is used to determine changes in sample dimension resulting from changes in temperature. This technique can measure thermal events such as the linear coefficient of thermal expansion (CTE), melting, glass transitions, cure shrinkage, and internal relaxations. Using a thermomechanical analyzer (Q400 TMA), it ismore » determined that DC 745 expands anisotropically when heated. This means that the material has a different CTE depending upon which direction is being measured. In this study, TMA experiments were designed in order to confirm anisotropic thermal behavior in multiple DC 745 samples of various ages and lots. TMA parameters such as temperature ramp rate, preload force, and temperature range were optimized in order to ensure the most accurate and useful data. A better understanding of the thermal expansion of DC 745 will allow for more accurate modeling of systems using this material.« less

  5. Partial volume correction and image segmentation for accurate measurement of standardized uptake value of grey matter in the brain.

    PubMed

    Bural, Gonca; Torigian, Drew; Basu, Sandip; Houseni, Mohamed; Zhuge, Ying; Rubello, Domenico; Udupa, Jayaram; Alavi, Abass

    2015-12-01

    Our aim was to explore a novel quantitative method [based upon an MRI-based image segmentation that allows actual calculation of grey matter, white matter and cerebrospinal fluid (CSF) volumes] for overcoming the difficulties associated with conventional techniques for measuring actual metabolic activity of the grey matter. We included four patients with normal brain MRI and fluorine-18 fluorodeoxyglucose (F-FDG)-PET scans (two women and two men; mean age 46±14 years) in this analysis. The time interval between the two scans was 0-180 days. We calculated the volumes of grey matter, white matter and CSF by using a novel segmentation technique applied to the MRI images. We measured the mean standardized uptake value (SUV) representing the whole metabolic activity of the brain from the F-FDG-PET images. We also calculated the white matter SUV from the upper transaxial slices (centrum semiovale) of the F-FDG-PET images. The whole brain volume was calculated by summing up the volumes of the white matter, grey matter and CSF. The global cerebral metabolic activity was calculated by multiplying the mean SUV with total brain volume. The whole brain white matter metabolic activity was calculated by multiplying the mean SUV for the white matter by the white matter volume. The global cerebral metabolic activity only reflects those of the grey matter and the white matter, whereas that of the CSF is zero. We subtracted the global white matter metabolic activity from that of the whole brain, resulting in the global grey matter metabolism alone. We then divided the grey matter global metabolic activity by grey matter volume to accurately calculate the SUV for the grey matter alone. The brain volumes ranged between 1546 and 1924 ml. The mean SUV for total brain was 4.8-7. Total metabolic burden of the brain ranged from 5565 to 9617. The mean SUV for white matter was 2.8-4.1. On the basis of these measurements we generated the grey matter SUV, which ranged from 8.1 to 11.3. The

  6. The Driving Behavior Survey as a Measure of Behavioral Stress Responses to MVA-Related PTSD

    PubMed Central

    Baker, Aaron S.; Litwack, Scott D.; Clapp, Joshua D.; Beck, J. Gayle; Sloan, Denise M.

    2014-01-01

    Numerous treatments are available that address the core symptoms of posttraumatic stress disorder (PTSD). However, there are a number of related behavioral stress responses that are not assessed with PTSD measures, yet these behavioral stress responses affect quality of life. The goal of the current study was to investigate whether a recently developed measure of behavioral stress response, the Driving Behavior Survey (DBS), was sensitive to change associated with treatment among a group of participants diagnosed with PTSD. The DBS indexes anxious driving behavior, which is frequently observed among individuals with motor vehicle accident-related PTSD. Participants (n = 40) were racially diverse adults (M age = 40.78, 63% women) who met diagnostic criteria for motor vehicle accident-related PTSD. Hierarchical linear modeling analyses indicated that participants who were assigned to a brief, exposure-based intervention displayed significant reductions on the DBS subscales relative to participants assigned to the wait-list control condition (r = .41–.43). Moreover, mediational analyses indicated that the observed reductions on the DBS subscales were not better accounted for by reductions in PTSD. Taken together, these findings suggest that the DBS subscales are sensitive to changes associated with PTSD treatment and can be used to augment outcome assessment in PTSD treatment trials. PMID:24800313

  7. k-Space Image Correlation Spectroscopy: A Method for Accurate Transport Measurements Independent of Fluorophore Photophysics

    PubMed Central

    Kolin, David L.; Ronis, David; Wiseman, Paul W.

    2006-01-01

    We present the theory and application of reciprocal space image correlation spectroscopy (kICS). This technique measures the number density, diffusion coefficient, and velocity of fluorescently labeled macromolecules in a cell membrane imaged on a confocal, two-photon, or total internal reflection fluorescence microscope. In contrast to r-space correlation techniques, we show kICS can recover accurate dynamics even in the presence of complex fluorophore photobleaching and/or “blinking”. Furthermore, these quantities can be calculated without nonlinear curve fitting, or any knowledge of the beam radius of the exciting laser. The number densities calculated by kICS are less sensitive to spatial inhomogeneity of the fluorophore distribution than densities measured using image correlation spectroscopy. We use simulations as a proof-of-principle to show that number densities and transport coefficients can be extracted using this technique. We present calibration measurements with fluorescent microspheres imaged on a confocal microscope, which recover Stokes-Einstein diffusion coefficients, and flow velocities that agree with single particle tracking measurements. We also show the application of kICS to measurements of the transport dynamics of α5-integrin/enhanced green fluorescent protein constructs in a transfected CHO cell imaged on a total internal reflection fluorescence microscope using charge-coupled device area detection. PMID:16861272

  8. Note: long range and accurate measurement of deep trench microstructures by a specialized scanning tunneling microscope.

    PubMed

    Ju, Bing-Feng; Chen, Yuan-Liu; Zhang, Wei; Zhu, Wule; Jin, Chao; Fang, F Z

    2012-05-01

    A compact but practical scanning tunneling microscope (STM) with high aspect ratio and high depth capability has been specially developed. Long range scanning mechanism with tilt-adjustment stage is adopted for the purpose of adjusting the probe-sample relative angle to compensate the non-parallel effects. A periodical trench microstructure with a pitch of 10 μm has been successfully imaged with a long scanning range up to 2.0 mm. More innovatively, a deep trench with depth and step height of 23.0 μm has also been successfully measured, and slope angle of the sidewall can approximately achieve 67°. The probe can continuously climb the high step and exploring the trench bottom without tip crashing. The new STM could perform long range measurement for the deep trench and high step surfaces without image distortion. It enables accurate measurement and quality control of periodical trench microstructures.

  9. Detailed behavioral assessment promotes accurate diagnosis in patients with disorders of consciousness

    PubMed Central

    Gilutz, Yael; Lazary, Avraham; Karpin, Hana; Vatine, Jean-Jacques; Misha, Tamar; Fortinsky, Hadassah; Sharon, Haggai

    2015-01-01

    Introduction: Assessing the awareness level in patients with disorders of consciousness (DOC) is made on the basis of exhibited behaviors. However, since motor signs of awareness (i.e., non-reflex motor responses) can be very subtle, differentiating the vegetative from minimally conscious states (which is in itself not clear-cut) is often challenging. Even the careful clinician relying on standardized scales may arrive at a wrong diagnosis. Aim: To report our experience in tackling this problem by using two in-house use assessment procedures developed at Reuth Rehabilitation Hospital, and demonstrate their clinical significance by reviewing two cases. Methods: (1) Reuth DOC Response Assessment (RDOC-RA) –administered in addition to the standardized tools, and emphasizes the importance of assessing a wide range of motor responses. In our experience, in some patients the only evidence for awareness may be a private specific movement that is not assessed by standard assessment tools. (2) Reuth DOC Periodic Intervention Model (RDOC-PIM) – current literature regarding assessment and diagnosis in DOC refers mostly to the acute phase of up to 1 year post injury. However, we have found major changes in responsiveness occurring 1 year or more post-injury in many patients. Therefore, we conduct periodic assessments at predetermined times points to ensure patients are not misdiagnosed or neurological changes overlooked. Results: In the first case the RDOC-RA promoted a more accurate diagnosis than that based on standardized scales alone. The second case shows how the RDOC-PIM allowed us to recognize late recovery and promoted reinstatement of treatment with good results. Conclusion: Adding a detailed periodic assessment of DOC patients to existing scales can yield critical information, promoting better diagnosis, treatment, and clinical outcomes. We discuss the implications of this observation for the future development and validation of assessment tools in DOC patients

  10. A scale for measuring hygiene behavior: development, reliability and validity.

    PubMed

    Stevenson, Richard J; Case, Trevor I; Hodgson, Deborah; Porzig-Drummond, Renata; Barouei, Javad; Oaten, Megan J

    2009-09-01

    There is currently no general self-report measure for assessing hygiene behavior. This article details the development and testing of such a measure. In studies 1 to 4, a total of 855 participants were used for scale and subscale development and for reliability and validity testing. The latter involved establishing the relationships between self-reported hygiene behavior and existing measures, hand hygiene behavior, illness rates, and a physiological marker of immune function. In study 5, a total of 507 participants were used to assess the psychometric properties of the final revised version of the scale. The final 23-item scale comprised 5 subscales: general, household, food-related, handwashing technique, and personal hygiene. Studies 1 to 4 confirmed the scale's reliability and validity, and study 5 confirmed the scale's 5-factor structure. The scale is potentially suitable for multiple uses, in various settings, and for experimental and correlational approaches.

  11. Nonsuicidal self-injury: relationship to behavioral and self-rating measures of impulsivity and self-aggression.

    PubMed

    McCloskey, Michael S; Look, Amy E; Chen, Eunice Y; Pajoumand, Golnaz; Berman, Mitchell E

    2012-04-01

    Previous research using self-report measures has shown an association between nonsuicidal self-injurious behavior (NSSI) and impulsive tendencies. However, self-injurers have not been shown to be different from comparison groups on laboratory tasks putatively assessing impulsive behavior. One explanation for these contradictory findings is that self-report and laboratory measures of impulsive behavior tap into distinct but related constructs. Moreover, performance on laboratory measures of impulsive behavior can be influenced by myriad contextual and affective factors not present during past self-reported NSSI events. Accordingly, a relationship between behavioral tasks of impulsivity and self-injurious behavior could emerge if both are assessed relatively close in time under controlled laboratory conditions. To test this possibility, both self-ratings and laboratory task measures of self-injurious and impulsive behavior were employed in the current study. This multi-modal assessment approach revealed that self-rated impulsivity was associated with both self-report and behavioral measures of self-injurious behavior. Moreover, behavioral measures of impulsivity were associated with self-injurious behavior, but not NSSI history. These results provide support for the notion that a multi-modal approach to assessing self-injurious behavior is important for better understanding the correlates of nonsuicidal self-injury. © 2012 The American Association of Suicidology.

  12. "Bien Educado": Measuring the Social Behaviors of Mexican American Children

    ERIC Educational Resources Information Center

    Bridges, Margaret; Cohen, Shana R.; McGuire, Leah Walker; Yamada, Hiro; Fuller, Bruce; Mireles, Laurie; Scott, Lyn

    2012-01-01

    Young children's expected social behaviors develop within particular cultural contexts and contribute to their academic experience in large part through their relationships with their teachers. Commonly used measures focus on children's problem behaviors, developed from psychopathology traditions, and rarely situate normative and positive…

  13. Reliability and Validity of a Measure of Preschool Teachers' Attributions for Disruptive Behavior

    ERIC Educational Resources Information Center

    Carter, Lauren M.; Williford, Amanda P.; LoCasale-Crouch, Jennifer

    2014-01-01

    Research Findings: This study examined the quality of teacher attributions for child disruptive behavior using a new measure, the Preschool Teaching Attributions measure. A sample of 153 early childhood teachers and 432 children participated. All teachers completed the behavior attributions measure, as well as measures regarding demographics,…

  14. Interrelating Behavioral Measures of Distress Tolerance with Self-Reported Experiential Avoidance

    PubMed Central

    Schloss, Heather M.

    2011-01-01

    Experiential avoidance and distress intolerance play a central role in novel behavior therapies, yet they appear to overlap considerably the REBT concept of low frustration tolerance. Using baseline data from 100 adult cigarette smokers enrolled in a clinical trial of smoking cessation therapies, the present study evaluated the convergent validity of common questionnaire measures of experiential avoidance (Acceptance and Action Questionnaire; AAQ; Hayes et al. 2004, and Avoidance and Inflexibility Scale: AIS; Gifford et al. 2004) and behavioral measures of distress tolerance (computerized Mirror Tracing Persistence Task: MTPT-C: Strong et al. 2003; computerized Paced Auditory Serial Addition Task; PASAT-C; Lejuez et al. 2003). The distress tolerance measures correlated significantly (r = .29) with one another. However, the questionnaire measures of experiential avoidance did not correlate with each other, nor with the behavioral measures. Further research is needed on the validity of measuring experiential avoidance by self-report and of the overlap versus distinctiveness of seemingly similar constructs such as experiential avoidance, distress tolerance, and frustration tolerance. PMID:21448252

  15. An Accurate Non-Cooperative Method for Measuring Textureless Spherical Target Based on Calibrated Lasers.

    PubMed

    Wang, Fei; Dong, Hang; Chen, Yanan; Zheng, Nanning

    2016-12-09

    Strong demands for accurate non-cooperative target measurement have been arising recently for the tasks of assembling and capturing. Spherical objects are one of the most common targets in these applications. However, the performance of the traditional vision-based reconstruction method was limited for practical use when handling poorly-textured targets. In this paper, we propose a novel multi-sensor fusion system for measuring and reconstructing textureless non-cooperative spherical targets. Our system consists of four simple lasers and a visual camera. This paper presents a complete framework of estimating the geometric parameters of textureless spherical targets: (1) an approach to calibrate the extrinsic parameters between a camera and simple lasers; and (2) a method to reconstruct the 3D position of the laser spots on the target surface and achieve the refined results via an optimized scheme. The experiment results show that our proposed calibration method can obtain a fine calibration result, which is comparable to the state-of-the-art LRF-based methods, and our calibrated system can estimate the geometric parameters with high accuracy in real time.

  16. An Accurate Non-Cooperative Method for Measuring Textureless Spherical Target Based on Calibrated Lasers

    PubMed Central

    Wang, Fei; Dong, Hang; Chen, Yanan; Zheng, Nanning

    2016-01-01

    Strong demands for accurate non-cooperative target measurement have been arising recently for the tasks of assembling and capturing. Spherical objects are one of the most common targets in these applications. However, the performance of the traditional vision-based reconstruction method was limited for practical use when handling poorly-textured targets. In this paper, we propose a novel multi-sensor fusion system for measuring and reconstructing textureless non-cooperative spherical targets. Our system consists of four simple lasers and a visual camera. This paper presents a complete framework of estimating the geometric parameters of textureless spherical targets: (1) an approach to calibrate the extrinsic parameters between a camera and simple lasers; and (2) a method to reconstruct the 3D position of the laser spots on the target surface and achieve the refined results via an optimized scheme. The experiment results show that our proposed calibration method can obtain a fine calibration result, which is comparable to the state-of-the-art LRF-based methods, and our calibrated system can estimate the geometric parameters with high accuracy in real time. PMID:27941705

  17. Behavioral System Feedback Measurement Failure: Sweeping Quality under the Rug

    ERIC Educational Resources Information Center

    Mihalic, Maria T.; Ludwig, Timothy D.

    2009-01-01

    Behavioral Systems rely on valid measurement systems to manage processes and feedback and to deliver contingencies. An examination of measurement system components designed to track customer service quality of furniture delivery drivers revealed the measurement system failed to capture information it was designed to measure. A reason for this…

  18. Accurate measurement of heteronuclear dipolar couplings by phase-alternating R-symmetry (PARS) sequences in magic angle spinning NMR spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hou, Guangjin, E-mail: hou@udel.edu, E-mail: tpolenov@udel.edu; Lu, Xingyu, E-mail: luxingyu@udel.edu, E-mail: lexvega@comcast.net; Vega, Alexander J., E-mail: luxingyu@udel.edu, E-mail: lexvega@comcast.net

    2014-09-14

    We report a Phase-Alternating R-Symmetry (PARS) dipolar recoupling scheme for accurate measurement of heteronuclear {sup 1}H-X (X = {sup 13}C, {sup 15}N, {sup 31}P, etc.) dipolar couplings in MAS NMR experiments. It is an improvement of conventional C- and R-symmetry type DIPSHIFT experiments where, in addition to the dipolar interaction, the {sup 1}H CSA interaction persists and thereby introduces considerable errors in the dipolar measurements. In PARS, phase-shifted RN symmetry pulse blocks applied on the {sup 1}H spins combined with π pulses applied on the X spins at the end of each RN block efficiently suppress the effect from {supmore » 1}H chemical shift anisotropy, while keeping the {sup 1}H-X dipolar couplings intact. Another advantage over conventional DIPSHIFT experiments, which require the signal to be detected in the form of a reduced-intensity Hahn echo, is that the series of π pulses refocuses the X chemical shift and avoids the necessity of echo formation. PARS permits determination of accurate dipolar couplings in a single experiment; it is suitable for a wide range of MAS conditions including both slow and fast MAS frequencies; and it assures dipolar truncation from the remote protons. The performance of PARS is tested on two model systems, [{sup 15}N]-N-acetyl-valine and [U-{sup 13}C,{sup 15}N]-N-formyl-Met-Leu-Phe tripeptide. The application of PARS for site-resolved measurement of accurate {sup 1}H-{sup 15}N dipolar couplings in the context of 3D experiments is presented on U-{sup 13}C,{sup 15}N-enriched dynein light chain protein LC8.« less

  19. Toward Objective Monitoring of Ingestive Behavior in Free-living Population

    PubMed Central

    Sazonov, Edward S.; Schuckers, Stephanie A.C.; Lopez-Meyer, Paulo; Makeyev, Oleksandr; Melanson, Edward L.; Neuman, Michael R.; Hill, James O.

    2010-01-01

    Understanding of eating behaviors associated with obesity requires objective and accurate monitoring of food intake patterns. Accurate methods are available for measuring total energy expenditure and its components in free-living populations, but methods for measuring food intake in free-living people are far less accurate and involve self-reporting or subjective monitoring. We suggest that chews and swallows can be used for objective monitoring of ingestive behavior. This hypothesis was verified in a human study involving 20 subjects. Chews and swallows were captured during periods of quiet resting, talking, and meals of varying size. The counts of chews and swallows along with other derived metrics were used to build prediction models for detection of food intake, differentiation between liquids and solids, and for estimation of the mass of ingested food. The proposed prediction models were able to detect periods of food intake with >95% accuracy and a fine time resolution of 30 s, differentiate solid foods from liquids with >91% accuracy, and predict mass of ingested food with >91% accuracy for solids and >83% accuracy for liquids. In earlier publications, we have shown that chews and swallows can be captured by noninvasive sensors that could be developed into a wearable device. Thus, the proposed methodology could lead to the development of an innovative new way of assessing human eating behavior in free-living conditions. PMID:19444225

  20. Toward objective monitoring of ingestive behavior in free-living population.

    PubMed

    Sazonov, Edward S; Schuckers, Stephanie A C; Lopez-Meyer, Paulo; Makeyev, Oleksandr; Melanson, Edward L; Neuman, Michael R; Hill, James O

    2009-10-01

    Understanding of eating behaviors associated with obesity requires objective and accurate monitoring of food intake patterns. Accurate methods are available for measuring total energy expenditure and its components in free-living populations, but methods for measuring food intake in free-living people are far less accurate and involve self-reporting or subjective monitoring. We suggest that chews and swallows can be used for objective monitoring of ingestive behavior. This hypothesis was verified in a human study involving 20 subjects. Chews and swallows were captured during periods of quiet resting, talking, and meals of varying size. The counts of chews and swallows along with other derived metrics were used to build prediction models for detection of food intake, differentiation between liquids and solids, and for estimation of the mass of ingested food. The proposed prediction models were able to detect periods of food intake with >95% accuracy and a fine time resolution of 30 s, differentiate solid foods from liquids with >91% accuracy, and predict mass of ingested food with >91% accuracy for solids and >83% accuracy for liquids. In earlier publications, we have shown that chews and swallows can be captured by noninvasive sensors that could be developed into a wearable device. Thus, the proposed methodology could lead to the development of an innovative new way of assessing human eating behavior in free-living conditions.

  1. Behavioral similarity measurement based on image processing for robots that use imitative learning

    NASA Astrophysics Data System (ADS)

    Sterpin B., Dante G.; Martinez S., Fernando; Jacinto G., Edwar

    2017-02-01

    In the field of the artificial societies, particularly those are based on memetics, imitative behavior is essential for the development of cultural evolution. Applying this concept for robotics, through imitative learning, a robot can acquire behavioral patterns from another robot. Assuming that the learning process must have an instructor and, at least, an apprentice, the fact to obtain a quantitative measurement for their behavioral similarity, would be potentially useful, especially in artificial social systems focused on cultural evolution. In this paper the motor behavior of both kinds of robots, for two simple tasks, is represented by 2D binary images, which are processed in order to measure their behavioral similarity. The results shown here were obtained comparing some similarity measurement methods for binary images.

  2. Forced reeling of Bombyx mori silk: separating behavior and processing conditions.

    PubMed

    Mortimer, Beth; Holland, Chris; Vollrath, Fritz

    2013-10-14

    Controlled reeling is a powerful tool to investigate the details of silk processing. However, consistent forced reeling of silkworms is hindered by the significant degree of behaviorally induced variation caused by the animal. This paper proposes silkworm paralysis as a novel method to control the animal and thus in vivo spinning conditions. Using these methods, we achieve low and consistent reeling forces during the collection of over 500 m of individual silk fiber while monitoring filament variability, morphology, and properties. Novel techniques to measure the irregular silk cross-sectional areas lead to the more accurate calculation of the true engineering values and mechanical property variation of individual silk fibers. Combining controlled reeling and accurate thread measurement techniques allows us to present the relative contributions of processing and behavior in the performance envelope of Bombyx mori silk.

  3. The standard centrifuge method accurately measures vulnerability curves of long-vesselled olive stems.

    PubMed

    Hacke, Uwe G; Venturas, Martin D; MacKinnon, Evan D; Jacobsen, Anna L; Sperry, John S; Pratt, R Brandon

    2015-01-01

    The standard centrifuge method has been frequently used to measure vulnerability to xylem cavitation. This method has recently been questioned. It was hypothesized that open vessels lead to exponential vulnerability curves, which were thought to be indicative of measurement artifact. We tested this hypothesis in stems of olive (Olea europea) because its long vessels were recently claimed to produce a centrifuge artifact. We evaluated three predictions that followed from the open vessel artifact hypothesis: shorter stems, with more open vessels, would be more vulnerable than longer stems; standard centrifuge-based curves would be more vulnerable than dehydration-based curves; and open vessels would cause an exponential shape of centrifuge-based curves. Experimental evidence did not support these predictions. Centrifuge curves did not vary when the proportion of open vessels was altered. Centrifuge and dehydration curves were similar. At highly negative xylem pressure, centrifuge-based curves slightly overestimated vulnerability compared to the dehydration curve. This divergence was eliminated by centrifuging each stem only once. The standard centrifuge method produced accurate curves of samples containing open vessels, supporting the validity of this technique and confirming its utility in understanding plant hydraulics. Seven recommendations for avoiding artefacts and standardizing vulnerability curve methodology are provided. © 2014 The Authors. New Phytologist © 2014 New Phytologist Trust.

  4. Accurate method for luminous transmittance and signal detection quotients measurements in sunglasses lenses

    NASA Astrophysics Data System (ADS)

    Loureiro, A. D.; Gomes, L. M.; Ventura, L.

    2018-02-01

    The international standard ISO 12312-1 proposes transmittance tests that quantify how dark sunglasses lenses are and whether or not they are suitable for driving. To perform these tests a spectrometer is required. In this study, we present and analyze theoretically an accurate alternative method for performing these measurements using simple components. Using three LEDs and a four-channel sensor we generated weighting functions similar to the standard ones for luminous and traffic lights transmittances. From 89 sunglasses lens spectroscopy data, we calculated luminous transmittance and signal detection quotients using our obtained weighting functions and the standard ones. Mean-difference Tukey plots were used to compare the results. All tested sunglasses lenses were classified in the right category and correctly as suitable or not for driving. The greatest absolute errors for luminous transmittance and red, yellow, green and blue signal detection quotients were 0.15%, 0.17, 0.06, 0.04 and 0.18, respectively. This method will be used in a device capable to perform transmittance tests (visible, traffic lights and ultraviolet (UV)) according to the standard. It is important to measure rightly luminous transmittance and relative visual attenuation quotients to report correctly whether or not sunglasses are suitable for driving. Moreover, standard UV requirements depend on luminous transmittance.

  5. Hyperspectral imaging-based spatially-resolved technique for accurate measurement of the optical properties of horticultural products

    NASA Astrophysics Data System (ADS)

    Cen, Haiyan

    Hyperspectral imaging-based spatially-resolved technique is promising for determining the optical properties and quality attributes of horticultural and food products. However, considerable challenges still exist for accurate determination of spectral absorption and scattering properties from intact horticultural products. The objective of this research was, therefore, to develop and optimize hyperspectral imaging-based spatially-resolved technique for accurate measurement of the optical properties of horticultural products. Monte Carlo simulations and experiments for model samples of known optical properties were performed to optimize the inverse algorithm of a single-layer diffusion model and the optical designs, for extracting the absorption (micro a) and reduced scattering (micros') coefficients from spatially-resolved reflectance profiles. The logarithm and integral data transformation and the relative weighting methods were found to greatly improve the parameter estimation accuracy with the relative errors of 10.4%, 10.7%, and 11.4% for micro a, and 6.6%, 7.0%, and 7.1% for micros', respectively. More accurate measurements of optical properties were obtained when the light beam was of Gaussian type with the diameter of less than 1 mm, and the minimum and maximum source-detector distances were 1.5 mm and 10--20 transport mean free paths, respectively. An optical property measuring prototype was built, based on the optimization results, and evaluated for automatic measurement of absorption and reduced scattering coefficients for the wavelengths of 500--1,000 nm. The instrument was used to measure the optical properties, and assess quality/maturity, of 500 'Redstar' peaches and 1039 'Golden Delicious' (GD) and 1040 'Delicious' (RD) apples. A separate study was also conducted on confocal laser scanning and scanning electron microscopic image analysis and compression test of fruit tissue specimens to measure the structural and mechanical properties of 'Golden

  6. Accurate color measurement methods for medical displays.

    PubMed

    Saha, Anindita; Kelley, Edward F; Badano, Aldo

    2010-01-01

    The necessity for standard instrumentation and measurements of color that are repeatable and reproducible is the major motivation behind this work. Currently, different instrumentation and methods can yield very different results when measuring the same feature such as color uniformity or color difference. As color increasingly comes into play in medical imaging diagnostics, display color will have to be quantified in order to assess whether the display should be used for imaging purposes. The authors report on the characterization of three novel probes for measuring display color with minimal contamination from screen areas outside the measurement spot or from off-normal emissions. They compare three probe designs: A modified small-spot luminance probe and two conic probe designs based on black frusta. To compare the three color probe designs, spectral and luminance measurements were taken with specialized instrumentation to determine the luminance changes and color separation abilities of the probes. The probes were characterized with a scanning slit method, veiling glare, and a moving laser and LED arrangement. The scanning slit measurement was done using a black slit plate over a white line on an LCD monitor. The luminance was measured in 1 mm increments from the center of the slit to +/- 15 mm above and below the slit at different distances between the probe and the slit. The veiling glare setup consisted of measurements of the luminance of a black spot pattern with a white disk of radius of 100 mm as the black spot increases in 1 mm radius increments. The moving LED and laser method consisted of a red and green light orthogonal to the probe tip for the light to directly shine into the probe. The green light source was moved away from the red source in 1 cm increments to measure color stray-light contamination at different probe distances. The results of the color testing using the LED and laser methods suggest a better performance of one of the frusta probes

  7. A Teacher-Report Measure of Children's Task-Avoidant Behavior: A Validation Study of the Behavioral Strategy Rating Scale

    ERIC Educational Resources Information Center

    Zhang, Xiao; Nurmi, Jari-Erik; Kiuru, Noona; Lerkkanen, Marja-Kristiina; Aunola, Kaisa

    2011-01-01

    This study aims to validate a teacher-report measure of children's task-avoidant behavior, namely the Behavioral Strategy Rating Scale (BSRS), in a sample of 352 Finnish children. In each of the four waves from Kindergarten to Grade 2, teachers rated children's task-avoidant behavior using the BSRS, children completed reading and mathematics…

  8. Accurate in situ measurement of complex refractive index and particle size in intralipid emulsions

    NASA Astrophysics Data System (ADS)

    Dong, Miao L.; Goyal, Kashika G.; Worth, Bradley W.; Makkar, Sorab S.; Calhoun, William R.; Bali, Lalit M.; Bali, Samir

    2013-08-01

    A first accurate measurement of the complex refractive index in an intralipid emulsion is demonstrated, and thereby the average scatterer particle size using standard Mie scattering calculations is extracted. Our method is based on measurement and modeling of the reflectance of a divergent laser beam from the sample surface. In the absence of any definitive reference data for the complex refractive index or particle size in highly turbid intralipid emulsions, we base our claim of accuracy on the fact that our work offers several critically important advantages over previously reported attempts. First, our measurements are in situ in the sense that they do not require any sample dilution, thus eliminating dilution errors. Second, our theoretical model does not employ any fitting parameters other than the two quantities we seek to determine, i.e., the real and imaginary parts of the refractive index, thus eliminating ambiguities arising from multiple extraneous fitting parameters. Third, we fit the entire reflectance-versus-incident-angle data curve instead of focusing on only the critical angle region, which is just a small subset of the data. Finally, despite our use of highly scattering opaque samples, our experiment uniquely satisfies a key assumption behind the Mie scattering formalism, namely, no multiple scattering occurs. Further proof of our method's validity is given by the fact that our measured particle size finds good agreement with the value obtained by dynamic light scattering.

  9. Accurate in situ measurement of complex refractive index and particle size in intralipid emulsions.

    PubMed

    Dong, Miao L; Goyal, Kashika G; Worth, Bradley W; Makkar, Sorab S; Calhoun, William R; Bali, Lalit M; Bali, Samir

    2013-08-01

    A first accurate measurement of the complex refractive index in an intralipid emulsion is demonstrated, and thereby the average scatterer particle size using standard Mie scattering calculations is extracted. Our method is based on measurement and modeling of the reflectance of a divergent laser beam from the sample surface. In the absence of any definitive reference data for the complex refractive index or particle size in highly turbid intralipid emulsions, we base our claim of accuracy on the fact that our work offers several critically important advantages over previously reported attempts. First, our measurements are in situ in the sense that they do not require any sample dilution, thus eliminating dilution errors. Second, our theoretical model does not employ any fitting parameters other than the two quantities we seek to determine, i.e., the real and imaginary parts of the refractive index, thus eliminating ambiguities arising from multiple extraneous fitting parameters. Third, we fit the entire reflectance-versus-incident-angle data curve instead of focusing on only the critical angle region, which is just a small subset of the data. Finally, despite our use of highly scattering opaque samples, our experiment uniquely satisfies a key assumption behind the Mie scattering formalism, namely, no multiple scattering occurs. Further proof of our method's validity is given by the fact that our measured particle size finds good agreement with the value obtained by dynamic light scattering.

  10. Fully automated laboratory and field-portable goniometer used for performing accurate and precise multiangular reflectance measurements

    NASA Astrophysics Data System (ADS)

    Harms, Justin D.; Bachmann, Charles M.; Ambeau, Brittany L.; Faulring, Jason W.; Ruiz Torres, Andres J.; Badura, Gregory; Myers, Emily

    2017-10-01

    Field-portable goniometers are created for a wide variety of applications. Many of these applications require specific types of instruments and measurement schemes and must operate in challenging environments. Therefore, designs are based on the requirements that are specific to the application. We present a field-portable goniometer that was designed for measuring the hemispherical-conical reflectance factor (HCRF) of various soils and low-growing vegetation in austere coastal and desert environments and biconical reflectance factors in laboratory settings. Unlike some goniometers, this system features a requirement for "target-plane tracking" to ensure that measurements can be collected on sloped surfaces, without compromising angular accuracy. The system also features a second upward-looking spectrometer to measure the spatially dependent incoming illumination, an integrated software package to provide full automation, an automated leveling system to ensure a standard frame of reference, a design that minimizes the obscuration due to self-shading to measure the opposition effect, and the ability to record a digital elevation model of the target region. This fully automated and highly mobile system obtains accurate and precise measurements of HCRF in a wide variety of terrain and in less time than most other systems while not sacrificing consistency or repeatability in laboratory environments.

  11. Sensible organizations: technology and methodology for automatically measuring organizational behavior.

    PubMed

    Olguin Olguin, Daniel; Waber, Benjamin N; Kim, Taemie; Mohan, Akshay; Ara, Koji; Pentland, Alex

    2009-02-01

    We present the design, implementation, and deployment of a wearable computing platform for measuring and analyzing human behavior in organizational settings. We propose the use of wearable electronic badges capable of automatically measuring the amount of face-to-face interaction, conversational time, physical proximity to other people, and physical activity levels in order to capture individual and collective patterns of behavior. Our goal is to be able to understand how patterns of behavior shape individuals and organizations. By using on-body sensors in large groups of people for extended periods of time in naturalistic settings, we have been able to identify, measure, and quantify social interactions, group behavior, and organizational dynamics. We deployed this wearable computing platform in a group of 22 employees working in a real organization over a period of one month. Using these automatic measurements, we were able to predict employees' self-assessments of job satisfaction and their own perceptions of group interaction quality by combining data collected with our platform and e-mail communication data. In particular, the total amount of communication was predictive of both of these assessments, and betweenness in the social network exhibited a high negative correlation with group interaction satisfaction. We also found that physical proximity and e-mail exchange had a negative correlation of r = -0.55 (p 0.01), which has far-reaching implications for past and future research on social networks.

  12. Accurate quantitative CF-LIBS analysis of both major and minor elements in alloys via iterative correction of plasma temperature and spectral intensity

    NASA Astrophysics Data System (ADS)

    Shuxia, ZHAO; Lei, ZHANG; Jiajia, HOU; Yang, ZHAO; Wangbao, YIN; Weiguang, MA; Lei, DONG; Liantuan, XIAO; Suotang, JIA

    2018-03-01

    The chemical composition of alloys directly determines their mechanical behaviors and application fields. Accurate and rapid analysis of both major and minor elements in alloys plays a key role in metallurgy quality control and material classification processes. A quantitative calibration-free laser-induced breakdown spectroscopy (CF-LIBS) analysis method, which carries out combined correction of plasma temperature and spectral intensity by using a second-order iterative algorithm and two boundary standard samples, is proposed to realize accurate composition measurements. Experimental results show that, compared to conventional CF-LIBS analysis, the relative errors for major elements Cu and Zn and minor element Pb in the copper-lead alloys has been reduced from 12%, 26% and 32% to 1.8%, 2.7% and 13.4%, respectively. The measurement accuracy for all elements has been improved substantially.

  13. E-Cigarettes Use Behavior and Experience of Adults: Qualitative Research Findings to Inform E-Cigarette Use Measure Development.

    PubMed

    Kim, Hyoshin; Davis, Andrew H; Dohack, Jaime L; Clark, Pamela I

    2017-02-01

    findings reveal that vaping is not a mere replacement for combustible cigarette smoking and that many users of e-cigarettes enjoy product characteristics such as flavors and "clouds" that are unavailable in combustible cigarettes. Therefore, commonly available cigarette smoking measures are not well suited to measurement of e-cigarette use behavior, and indication that new measures need to be developed to accurately track e-cigarette use. © The Author 2016. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. E-Cigarettes Use Behavior and Experience of Adults: Qualitative Research Findings to Inform E-Cigarette Use Measure Development

    PubMed Central

    Davis, Andrew H.; Dohack, Jaime L.; Clark, Pamela I.

    2017-01-01

    phenomenon and assessing the risks associated with using e-cigarette products. Our findings reveal that vaping is not a mere replacement for combustible cigarette smoking and that many users of e-cigarettes enjoy product characteristics such as flavors and “clouds” that are unavailable in combustible cigarettes. Therefore, commonly available cigarette smoking measures are not well suited to measurement of e-cigarette use behavior, and indication that new measures need to be developed to accurately track e-cigarette use. PMID:27613944

  15. Measuring P-V-T Phase Behavior with a Variable Volume View Cell

    ERIC Educational Resources Information Center

    Hoffmann, Markus M.; Salter, Jason D.

    2004-01-01

    An experiment using a variable volume cell is presented where students actively control and directly observe the phase equilibrium inside the view cell. Measuring and exploring P-V-T phase behavior through dielectric constant measurements conveys the important concept that solvent behavior can be changed continuously in the sc fluid state.

  16. Finite Element Modelling of a Field-Sensed Magnetic Suspended System for Accurate Proximity Measurement Based on a Sensor Fusion Algorithm with Unscented Kalman Filter

    PubMed Central

    Chowdhury, Amor; Sarjaš, Andrej

    2016-01-01

    The presented paper describes accurate distance measurement for a field-sensed magnetic suspension system. The proximity measurement is based on a Hall effect sensor. The proximity sensor is installed directly on the lower surface of the electro-magnet, which means that it is very sensitive to external magnetic influences and disturbances. External disturbances interfere with the information signal and reduce the usability and reliability of the proximity measurements and, consequently, the whole application operation. A sensor fusion algorithm is deployed for the aforementioned reasons. The sensor fusion algorithm is based on the Unscented Kalman Filter, where a nonlinear dynamic model was derived with the Finite Element Modelling approach. The advantage of such modelling is a more accurate dynamic model parameter estimation, especially in the case when the real structure, materials and dimensions of the real-time application are known. The novelty of the paper is the design of a compact electro-magnetic actuator with a built-in low cost proximity sensor for accurate proximity measurement of the magnetic object. The paper successively presents a modelling procedure with the finite element method, design and parameter settings of a sensor fusion algorithm with Unscented Kalman Filter and, finally, the implementation procedure and results of real-time operation. PMID:27649197

  17. Finite Element Modelling of a Field-Sensed Magnetic Suspended System for Accurate Proximity Measurement Based on a Sensor Fusion Algorithm with Unscented Kalman Filter.

    PubMed

    Chowdhury, Amor; Sarjaš, Andrej

    2016-09-15

    The presented paper describes accurate distance measurement for a field-sensed magnetic suspension system. The proximity measurement is based on a Hall effect sensor. The proximity sensor is installed directly on the lower surface of the electro-magnet, which means that it is very sensitive to external magnetic influences and disturbances. External disturbances interfere with the information signal and reduce the usability and reliability of the proximity measurements and, consequently, the whole application operation. A sensor fusion algorithm is deployed for the aforementioned reasons. The sensor fusion algorithm is based on the Unscented Kalman Filter, where a nonlinear dynamic model was derived with the Finite Element Modelling approach. The advantage of such modelling is a more accurate dynamic model parameter estimation, especially in the case when the real structure, materials and dimensions of the real-time application are known. The novelty of the paper is the design of a compact electro-magnetic actuator with a built-in low cost proximity sensor for accurate proximity measurement of the magnetic object. The paper successively presents a modelling procedure with the finite element method, design and parameter settings of a sensor fusion algorithm with Unscented Kalman Filter and, finally, the implementation procedure and results of real-time operation.

  18. Accurate 3D kinematic measurement of temporomandibular joint using X-ray fluoroscopic images

    NASA Astrophysics Data System (ADS)

    Yamazaki, Takaharu; Matsumoto, Akiko; Sugamoto, Kazuomi; Matsumoto, Ken; Kakimoto, Naoya; Yura, Yoshiaki

    2014-04-01

    Accurate measurement and analysis of 3D kinematics of temporomandibular joint (TMJ) is very important for assisting clinical diagnosis and treatment of prosthodontics and orthodontics, and oral surgery. This study presents a new 3D kinematic measurement technique of the TMJ using X-ray fluoroscopic images, which can easily obtain the TMJ kinematic data in natural motion. In vivo kinematics of the TMJ (maxilla and mandibular bone) is determined using a feature-based 2D/3D registration, which uses beads silhouette on fluoroscopic images and 3D surface bone models with beads. The 3D surface models of maxilla and mandibular bone with beads were created from CT scans data of the subject using the mouthpiece with the seven strategically placed beads. In order to validate the accuracy of pose estimation for the maxilla and mandibular bone, computer simulation test was performed using five patterns of synthetic tantalum beads silhouette images. In the clinical applications, dynamic movement during jaw opening and closing was conducted, and the relative pose of the mandibular bone with respect to the maxilla bone was determined. The results of computer simulation test showed that the root mean square errors were sufficiently smaller than 1.0 mm and 1.0 degree. In the results of clinical application, during jaw opening from 0.0 to 36.8 degree of rotation, mandibular condyle exhibited 19.8 mm of anterior sliding relative to maxillary articular fossa, and these measurement values were clinically similar to the previous reports. Consequently, present technique was thought to be suitable for the 3D TMJ kinematic analysis.

  19. The Influence of Restraint Systems on Panel Behavior

    NASA Technical Reports Server (NTRS)

    Jegley, Dawn C.

    2011-01-01

    When a panel is tested in uniaxial compression in a test machine, the boundary conditions are not quite the same as they would be if it were part of a complete structure. A restraint system may be used to simulate conditions found in a complete vehicle. Quantifying the quality of the restraint with only point-measurement devices can leave an inadequate characterization of the out-of-plane behavior. However, today s full-field displacement monitoring techniques allow for much more accurate views of the global panel deformation and strain, and therefore allow for a better understanding of panel behavior. In the current study, the behavior of a hat-stiffened and two rod-stiffened carbon-epoxy panels is considered. Panels were approximately 2 meters tall and 0.76 to 1.06 m wide. Unloaded edges were supported by knife edges and stiffeners were attached to a support structure at selected locations to restrain out-of-plane motion. A comparison is made between test results based on full-field measurements and analyses based on assumptions of boundary conditions of a completely rigid edge restraint and the absence of any edge restraint. Results indicate that motion at the restrained edges must be considered to obtain accurate test-analysis correlation.

  20. Methods for the accurate estimation of confidence intervals on protein folding ϕ-values

    PubMed Central

    Ruczinski, Ingo; Sosnick, Tobin R.; Plaxco, Kevin W.

    2006-01-01

    ϕ-Values provide an important benchmark for the comparison of experimental protein folding studies to computer simulations and theories of the folding process. Despite the growing importance of ϕ measurements, however, formulas to quantify the precision with which ϕ is measured have seen little significant discussion. Moreover, a commonly employed method for the determination of standard errors on ϕ estimates assumes that estimates of the changes in free energy of the transition and folded states are independent. Here we demonstrate that this assumption is usually incorrect and that this typically leads to the underestimation of ϕ precision. We derive an analytical expression for the precision of ϕ estimates (assuming linear chevron behavior) that explicitly takes this dependence into account. We also describe an alternative method that implicitly corrects for the effect. By simulating experimental chevron data, we show that both methods accurately estimate ϕ confidence intervals. We also explore the effects of the commonly employed techniques of calculating ϕ from kinetics estimated at non-zero denaturant concentrations and via the assumption of parallel chevron arms. We find that these approaches can produce significantly different estimates for ϕ (again, even for truly linear chevron behavior), indicating that they are not equivalent, interchangeable measures of transition state structure. Lastly, we describe a Web-based implementation of the above algorithms for general use by the protein folding community. PMID:17008714

  1. Accurate human limb angle measurement: sensor fusion through Kalman, least mean squares and recursive least-squares adaptive filtering

    NASA Astrophysics Data System (ADS)

    Olivares, A.; Górriz, J. M.; Ramírez, J.; Olivares, G.

    2011-02-01

    Inertial sensors are widely used in human body motion monitoring systems since they permit us to determine the position of the subject's limbs. Limb angle measurement is carried out through the integration of the angular velocity measured by a rate sensor and the decomposition of the components of static gravity acceleration measured by an accelerometer. Different factors derived from the sensors' nature, such as the angle random walk and dynamic bias, lead to erroneous measurements. Dynamic bias effects can be reduced through the use of adaptive filtering based on sensor fusion concepts. Most existing published works use a Kalman filtering sensor fusion approach. Our aim is to perform a comparative study among different adaptive filters. Several least mean squares (LMS), recursive least squares (RLS) and Kalman filtering variations are tested for the purpose of finding the best method leading to a more accurate and robust limb angle measurement. A new angle wander compensation sensor fusion approach based on LMS and RLS filters has been developed.

  2. Three Measures of Family Problem Solving Behavior: A Procedural Manual.

    ERIC Educational Resources Information Center

    Nickerson, Mark; And Others

    The procedural details of three measures of family problem-solving behavior are presented. These measures are used to code videotapes that are recorded when family members discuss and try to solve a family problem that they consider important. The measures were developed to accompany methods for training parents and their preadolescent and…

  3. Measuring homework completion in behavioral activation.

    PubMed

    Busch, Andrew M; Uebelacker, Lisa A; Kalibatseva, Zornitsa; Miller, Ivan W

    2010-07-01

    The aim of this study was to develop and validate an observer-based coding system for the characterization and completion of homework assignments during Behavioral Activation (BA). Existing measures of homework completion are generally unsophisticated, and there is no current measure of homework completion designed to capture the particularities of BA. The tested scale sought to capture the type of assignment, realm of functioning targeted, extent of completion, and assignment difficulty. Homework assignments were drawn from 12 (mean age = 48, 83% female) clients in two trials of a 10-session BA manual targeting treatment-resistant depression in primary care. The two coders demonstrated acceptable or better reliability on most codes, and unreliable codes were dropped from the proposed scale. In addition, correlations between homework completion and outcome were strong, providing some support for construct validity. Ultimately, this line of research aims to develop a user-friendly, reliable measure of BA homework completion that can be completed by a therapist during session.

  4. Mass spectrometry in Earth sciences: the precise and accurate measurement of time.

    PubMed

    Schaltegger, Urs; Wotzlaw, Jörn-Frederik; Ovtcharova, Maria; Chiaradia, Massimo; Spikings, Richard

    2014-01-01

    Precise determinations of the isotopic compositions of a variety of elements is a widely applied tool in Earth sciences. Isotope ratios are used to quantify rates of geological processes that occurred during the previous 4.5 billion years, and also at the present time. An outstanding application is geochronology, which utilizes the production of radiogenic daughter isotopes by the radioactive decay of parent isotopes. Geochronological tools, involving isotopic analysis of selected elements from smallest volumes of minerals by thermal ionization mass spectrometry, provide precise and accurate measurements of time throughout the geological history of our planet over nine orders of magnitude, from the accretion of the proto-planetary disk, to the timing of the last glaciation. This article summarizes the recent efforts of the Isotope Geochemistry, Geochronology and Thermochronology research group at the University of Geneva to advance the U-Pb geochronological tool to achieve unprecedented precision and accuracy, and presents two examples of its application to two significant open questions in Earth sciences: what are the triggers and timescales of volcanic supereruptions, and what were the causes of mass extinctions in the geological past, driven by global climatic and environmental deterioration?

  5. Measuring children's regulation of emotion-expressive behavior.

    PubMed

    Bar-Haim, Yair; Bar-Av, Gali; Sadeh, Avi

    2011-04-01

    Emotion regulation has become a pivotal concept in developmental and clinical research. However, the measurement of regulatory processes has proved extremely difficult, particularly in the context of within-subject designs. Here, we describe a formal conceptualization and a new experimental procedure, the Balloons Game, to measure a regulatory component of emotion-expressive behavior. We present the internal consistency and stability of the indices derived from the Balloons Game in a sample of 121 kindergarten children. External validation against measures that have been associated with emotion regulation processes is also provided. The findings suggest that the Balloons Game provides a reliable tool for the study of regulation of emotion expression in young children. PsycINFO Database Record (c) 2011 APA, all rights reserved.

  6. Enabling high grayscale resolution displays and accurate response time measurements on conventional computers.

    PubMed

    Li, Xiangrui; Lu, Zhong-Lin

    2012-02-29

    Display systems based on conventional computer graphics cards are capable of generating images with 8-bit gray level resolution. However, most experiments in vision research require displays with more than 12 bits of luminance resolution. Several solutions are available. Bit++ (1) and DataPixx (2) use the Digital Visual Interface (DVI) output from graphics cards and high resolution (14 or 16-bit) digital-to-analog converters to drive analog display devices. The VideoSwitcher (3) described here combines analog video signals from the red and blue channels of graphics cards with different weights using a passive resister network (4) and an active circuit to deliver identical video signals to the three channels of color monitors. The method provides an inexpensive way to enable high-resolution monochromatic displays using conventional graphics cards and analog monitors. It can also provide trigger signals that can be used to mark stimulus onsets, making it easy to synchronize visual displays with physiological recordings or response time measurements. Although computer keyboards and mice are frequently used in measuring response times (RT), the accuracy of these measurements is quite low. The RTbox is a specialized hardware and software solution for accurate RT measurements. Connected to the host computer through a USB connection, the driver of the RTbox is compatible with all conventional operating systems. It uses a microprocessor and high-resolution clock to record the identities and timing of button events, which are buffered until the host computer retrieves them. The recorded button events are not affected by potential timing uncertainties or biases associated with data transmission and processing in the host computer. The asynchronous storage greatly simplifies the design of user programs. Several methods are available to synchronize the clocks of the RTbox and the host computer. The RTbox can also receive external triggers and be used to measure RT with respect

  7. Accurate measurements of the thermal diffusivity of thin filaments by lock-in thermography

    NASA Astrophysics Data System (ADS)

    Salazar, Agustín; Mendioroz, Arantza; Fuente, Raquel; Celorrio, Ricardo

    2010-02-01

    In lock-in (modulated) thermography the lateral thermal diffusivity can be obtained from the slope of the linear relation between the phase of the surface temperature and the distance to the heating spot. However, this slope is greatly affected by heat losses, leading to an overestimation of the thermal diffusivity, especially for thin samples of poor thermal conducting materials. In this paper, we present a complete theoretical model to calculate the surface temperature of filaments heated by a focused and modulated laser beam. All heat losses have been included: conduction to the gas, convection, and radiation. Monofilaments and coated wires have been studied. Conduction to the gas has been identified as the most disturbing effect preventing from the direct use of the slope method to measure the thermal diffusivity. As a result, by keeping the sample in vacuum a slope method combining amplitude and phase can be used to obtain the accurate diffusivity value. Measurements performed in a wide variety of filaments confirm the validity of the conclusion. On the other hand, in the case of coated wires, the slope method gives an effective thermal diffusivity, which verifies the in-parallel thermal resistor model. As an application, the slope method has been used to retrieve the thermal conductivity of thin tubes by filling them with a liquid of known thermal properties.

  8. Toward accurate and valid estimates of greenhouse gas reductions from bikeway projects.

    DOT National Transportation Integrated Search

    2016-07-31

    We sought to accurately and validly model emissions generating and activities, including changes in traveler behavior and thus GHG : emissions in the wake of bikeway projects. We wanted the results to be applicable to practice and policy in Californi...

  9. Measuring farmer conservation behaviors: Challenges and best practices

    Treesearch

    Kristin Floress; Adam Reimer; Aaron Thompson; Mark Burbach; Cody Knutson; Linda Prokopy; Marc Ribaudo; Jessica Ulrich-Schad

    2018-01-01

    This article presents a guide for understanding the purposes and appropriate uses of different measures of conservation behavior. While applicable across natural resource management contexts, we primarily draw upon agricultural conservation research to illustrate our points. Farmers are often of interest to researchers, program managers, extension professionals, and...

  10. Accurate mass measurements and their appropriate use for reliable analyte identification.

    PubMed

    Godfrey, A Ruth; Brenton, A Gareth

    2012-09-01

    Accurate mass instrumentation is becoming increasingly available to non-expert users. This data can be mis-used, particularly for analyte identification. Current best practice in assigning potential elemental formula for reliable analyte identification has been described with modern informatic approaches to analyte elucidation, including chemometric characterisation, data processing and searching using facilities such as the Chemical Abstracts Service (CAS) Registry and Chemspider.

  11. Accurate measurement of volume and shape of resting and activated blood platelets from light scattering.

    PubMed

    Moskalensky, Alexander E; Yurkin, Maxim A; Konokhova, Anastasiya I; Strokotov, Dmitry I; Nekrasov, Vyacheslav M; Chernyshev, Andrei V; Tsvetovskaya, Galina A; Chikova, Elena D; Maltsev, Valeri P

    2013-01-01

    We introduce a novel approach for determination of volume and shape of individual blood platelets modeled as an oblate spheroid from angle-resolved light scattering with flow-cytometric technique. The light-scattering profiles (LSPs) of individual platelets were measured with the scanning flow cytometer and the platelet characteristics were determined from the solution of the inverse light-scattering problem using the precomputed database of theoretical LSPs. We revealed a phenomenon of parameter compensation, which is partly explained in the framework of anomalous diffraction approximation. To overcome this problem, additional a priori information on the platelet refractive index was used. It allowed us to determine the size of each platelet with subdiffraction precision and independent of the particular value of the platelet aspect ratio. The shape (spheroidal aspect ratio) distributions of platelets showed substantial differences between native and activated by 10 μM adenosine diphosphate samples. We expect that the new approach may find use in hematological analyzers for accurate measurement of platelet volume distribution and for determination of the platelet activation efficiency.

  12. Psychometric data of a questionnaire to measure cyberbullying bystander behavior and its behavioral determinants among adolescents.

    PubMed

    DeSmet, A; Bastiaensens, S; Van Cleemput, K; Poels, K; Vandebosch, H; Deboutte, G; Herrewijn, L; Malliet, S; Pabian, S; Van Broeckhoven, F; De Troyer, O; Deglorie, G; Van Hoecke, S; Samyn, K; De Bourdeaudhuij, I

    2018-06-01

    .This paper describes the items, scale validity and scale reliability of a self-report questionnaire that measures bystander behavior in cyberbullying incidents among adolescents, and its behavioral determinants. Determinants included behavioral intention, behavioral attitudes, moral disengagement attitudes, outcome expectations, self-efficacy, subjective norm and social skills. Questions also assessed (cyber-)bullying involvement. Validity and reliability information is based on a sample of 238 adolescents (M age=13.52 years, SD=0.57). Construct validity was assessed using Confirmatory Factor Analysis (CFA) or Exploratory Factor Analysis (EFA) in Mplus7 software. Reliability (Cronbach Alpha, α) was assessed in SPSS, version 22. Data and questionnaire are included in this article. Further information can be found in DeSmet et al. (2018) [1].

  13. Seeking: Accurate Measurement Techniques for Deep-Bone Density and Structure

    NASA Technical Reports Server (NTRS)

    Sibonga, Jean

    2009-01-01

    We are seeking a clinically-useful technology with enough sensitivity to assess the microstructure of "spongy" bone that is found in the marrow cavities of whole bones. However, this technology must be for skeletal sites surrounded by layers of soft tissues, such as the spine and the hip. Soft tissue interferes with conventional imaging and using a more accessible area -- for example, the wrist or the ankle of limbs-- as a proxy for the less accessible skeletal regions, will not be accurate. A non-radioactive technology is strongly preferred.

  14. Vocational Behavior 1990-1992: Personnel Practices, Organizational Behavior, Workplace Justice, and Industrial/Organizational Measurement Issues.

    ERIC Educational Resources Information Center

    Blau, Gary; And Others

    1993-01-01

    This annual review gives representative coverage of research on personnel practices and issues, work adjustment, organizational behavior, workplace justice (equal opportunities, harassment, etc.), and industrial/occupational measurement issues. The bibliography lists 438 references. (SK)

  15. Waist Circumference and Objectively Measured Sedentary Behavior in Rural School Adolescents

    ERIC Educational Resources Information Center

    Machado-Rodrigues, Aristides M.; Coelho e Silva, Manuel J.; Ribeiro, Luís P.; Fernandes, Romulo; Mota, Jorge; Malina, Robert M.

    2016-01-01

    Background: Research on relationships between lifestyle behaviors and adiposity in school youth is potentially important for identifying subgroups at risk. This study evaluates the associations between waist circumference (WC) and objective measures of sedentary behavior (SB) in a sample of rural school adolescents. Methods: The sample included…

  16. Strong genetic influences on measures of behavioral-regulation among inbred rat strains

    PubMed Central

    Richards, Jerry B.; Lloyd, David R.; Kuehlewind, Brandon; Militello, Leah; Paredez, Marita; Solberg -Woods, Leah; Palmer, Abraham A.

    2013-01-01

    A fundamental challenge for any complex nervous system is to regulate behavior in response to environmental challenges. Three measures of behavioral regulation were tested in a panel of 8 inbred rat strains. These measures were; 1) sensation seeking as assessed by locomotor response to novelty and the sensory reinforcing effects of light onset, 2) attention and impulsivity, as measured by a choice reaction time task, and 3) impulsivity as measured by a delay discounting task. Deficient behavioral regulation has been linked to a number of psychopathologies, including ADHD, Schizophrenia, Autism, drug abuse and eating disorders. Eight inbred rat strains (August Copenhagen Irish, Brown Norway, Buffalo, Fischer 344, Wistar Kyoto, Spontaneous Hypertensive Rat, Lewis, Dahl Salt Sensitive) were tested. With n=9 for each strain, we observed robust strain differences for all tasks; heritability was estimated between 0.43 and 0.66. Performance of the 8 inbred rat strains on the choice reaction time task was compared to the performance of out bred Sprague Dawley (n=28) and Heterogeneous strain rats (n=48). The results indicate a strong genetic influence on complex tasks related to behavioral regulation and indicate that some of measures tap common genetically-driven processes. Furthermore, our results establish the potential for future studies aimed at identifying specific alleles that influence variability for these traits. Identification of such alleles could contribute to our understanding of the molecular genetic basis of behavioral regulation, which is of fundamental importance and likely contributes to multiple psychiatric disorders. PMID:23710681

  17. Design and Measurement of a Digital Phase Locked BWO for Accurately Extracting the Quality Factors in a Biconcave Resonator System

    NASA Astrophysics Data System (ADS)

    Gao, Yuanci; Charles, Jones R.; Yu, Guofen; Jyotsna, Dutta M.

    2012-03-01

    A long loop phase locked backward-wave oscillator (BWO) for a high quality factor resonator system operating at D-band frequencies (130-170GHz) was described, the phase noise of the phased locked BWO was analyzed and measured at typical frequencies. When it used with a high quality factor open resonator for measuring the quality factor of simple harmonic resonators based on the magnitude transfer characteristic, this system has proven to be capable of accurate measuring the quality factor as high as 0.8 million with an uncertainty of less than 1.3% (Lorentzian fitting) at typical frequencies in the range of 130GHz-170GHz.

  18. Microbalance accurately measures extremely small masses

    NASA Technical Reports Server (NTRS)

    Patashnick, H.

    1970-01-01

    Oscillating fiber microbalance has a vibrating quartz fiber as balance arm to hold the mass to be weighed. Increasing fiber weight decreases its resonant frequency. Scaler and timer measure magnitude of the shift. This instrument withstands considerable physical abuse and has calibration stability at normal room temperatures.

  19. Comparing Multi-Informant Assessment Measures of Parental Monitoring and Their Links with Adolescent Delinquent Behavior

    PubMed Central

    Augenstein, Tara M.; Thomas, Sarah A.; Ehrlich, Katherine B.; Daruwala, Samantha; Reyes, Shelby M.; Chrabaszcz, Jeffrey S.; De Los Reyes, Andres

    2016-01-01

    SYNOPSIS Objective Parents’ poor monitoring of adolescents’ whereabouts and activities is commonly linked to adolescents’ increased engagement in delinquent behaviors. Yet, different domains of parental monitoring (parental monitoring behaviors vs. parental knowledge) and reports from multiple informants (parent vs. adolescent) may vary in their links to delinquent behavior. Design Seventy-four parental caregivers and 74 adolescents completed survey measures of parental monitoring and knowledge, and adolescents completed self-report surveys of delinquent behavior. Results We observed low-to-moderate magnitudes of correspondence between parent- and adolescent-reports of parental monitoring behaviors and parental knowledge. Adolescent self-reported delinquent behavior related to parent and adolescent reports of parental monitoring behaviors and parental knowledge, with adolescents who self-reported engagement in delinquent behaviors evidencing lower levels of parental knowledge and higher levels of poor monitoring compared to adolescents who did not self-report engagement in delinquent behaviors. Adolescent self-reported engagement in delinquent behaviors evidenced stronger links to parental monitoring when based on adolescent reports of monitoring (relative to parent reports), whereas stronger links held between adolescent self-reported delinquent behavior and parental knowledge when based on parent reports of knowledge (relative to adolescent reports). Conclusions Links between monitoring and adolescents’ delinquent behavior vary by the kind of monitoring measure completed as well as the informant completing the measure. These findings inform measurement selection in research and clinical assessments of parental monitoring and adolescent delinquent behavior. PMID:27482171

  20. Measurement of the linear viscoelastic behavior of antimisting kerosene

    NASA Technical Reports Server (NTRS)

    Ferry, J. D.

    1983-01-01

    Measurements of dynamic viscoelastic properties in very small oscillating shear deformations was made on solutions of a jet fuel, Jet A, containing an antimisting polymeric additive, FM-9. A few measurements were also made on solutions of FM-9 in a mixed solvent of mineral oil, Tetralin, and 0-terphenyl. Two samples of FM-9 had approximate number-average molecular weights of 12,000,000 and 8,100,000 as deduced from analysis of the measurements. The ranges of variables were 2.42 to 4.03 g/1 in concentration (0.3 to 0.5% by weight), 1 to 35 in temperature, 1.3 to 9.4 cp in solvent viscosity, and 103 to 6100 Hz in frequency. Measurements in the Jet A solvent were made both with and without a modifying carrier. The results were compared with the Zimm theory and the viscoelastic behavior was found to resemble rather closely that of ordinary non-polar polymers in theta solvents. The relation of the results to the antithixotropic behavior of such solutions a high shear rates is discussed in terms of intramolecular and intermolecular interactions.

  1. Accurate isotopic fission yields of electromagnetically induced fission of 238U measured in inverse kinematics at relativistic energies

    NASA Astrophysics Data System (ADS)

    Pellereau, E.; Taïeb, J.; Chatillon, A.; Alvarez-Pol, H.; Audouin, L.; Ayyad, Y.; Bélier, G.; Benlliure, J.; Boutoux, G.; Caamaño, M.; Casarejos, E.; Cortina-Gil, D.; Ebran, A.; Farget, F.; Fernández-Domínguez, B.; Gorbinet, T.; Grente, L.; Heinz, A.; Johansson, H.; Jurado, B.; Kelić-Heil, A.; Kurz, N.; Laurent, B.; Martin, J.-F.; Nociforo, C.; Paradela, C.; Pietri, S.; Rodríguez-Sánchez, J. L.; Schmidt, K.-H.; Simon, H.; Tassan-Got, L.; Vargas, J.; Voss, B.; Weick, H.

    2017-05-01

    SOFIA (Studies On Fission with Aladin) is a novel experimental program, dedicated to accurate measurements of fission-fragment isotopic yields. The setup allows us to fully identify, in nuclear charge and mass, both fission fragments in coincidence for the whole fission-fragment range. It was installed at the GSI facility (Darmstadt), to benefit from the relativistic heavy-ion beams available there, and thus to use inverse kinematics. This paper reports on fission yields obtained in electromagnetically induced fission of 238U.

  2. Self-report and long-term field measures of MP3 player use: how accurate is self-report?

    PubMed

    Portnuff, C D F; Fligor, B J; Arehart, K H

    2013-02-01

    This study was designed to evaluate the usage patterns of portable listening device (PLD) listeners, and the relationships between self-report measures and long-term dosimetry measures of listening habits. This study used a descriptive correlational design. Participants (N = 52) were 18-29 year old men and women who completed surveys. A randomly assigned subset (N = 24) of participants had their listening monitored by dosimetry for one week. Median weekly noise doses reported and measured through dosimetry were low (9-93%), but 14.3% of participants reported exceeding a 100% noise dose weekly. When measured by dosimetry, 16.7% of participants exceeded a 100% noise dose weekly. The self-report question that best predicted the dosimetry-measured dose asked participants to report listening duration and usual listening level on a visual-analog scale. This study reports a novel dosimetry system that can provide accurate measures of PLD use over time. When not feasible, though, the self-report question described could provide a useful research or clinical tool to estimate exposure from PLD use. Among the participants in this study, a small but substantial percentage of PLD users incurred exposure from PLD use alone that increases their risk of music-induced hearing loss.

  3. A New Measure of Reading Habit: Going Beyond Behavioral Frequency

    PubMed Central

    Schmidt, Fabian T. C.; Retelsdorf, Jan

    2016-01-01

    Reading habit is considered an important construct in reading research as it serves as a significant predictor of reading achievement. However, there is still no consensus on how to best measure reading habit. In recent research, it has mostly been measured as behavioral frequency; this approach neglects the fact that repeated behavior does not cover the broad content of habitual behavior—such as automaticity and the expression of one’s identity. In this study, we aimed to adapt a 10-item scale on the basis of the Self-Report Habit Index by Verplanken and Orbell (2003) that is comprehensive but still economical for measuring reading habit. It was tested by drawing on a sample of N = 1,418 upper secondary school students. The scale showed good psychometric properties and the internal and external validity was supported. Moreover, the scale predicted reading achievement and decoding speed over and above reading frequency. The implications of an elaborated but still economical way of measuring reading habit are discussed giving new impetus on research on reading habit, challenging conventional approaches of traditional measures. PMID:27660619

  4. Test-retest reliability of behavioral measures of impulsive choice, impulsive action, and inattention

    PubMed Central

    Weafer, Jessica; Baggott, Matthew J.; de Wit, Harriet

    2014-01-01

    Behavioral measures of impulsivity are widely used in substance abuse research, yet relatively little attention has been devoted to establishing their psychometric properties, especially their reliability over repeated administration. The current study examined the test-retest reliability of a battery of standardized behavioral impulsivity tasks, including measures of impulsive choice (delay discounting, probability discounting, and the Balloon Analogue Risk Task), impulsive action (the stop signal task, the go/no-go task, and commission errors on the continuous performance task), and inattention (attention lapses on a simple reaction time task and omission errors on the continuous performance task). Healthy adults (n=128) performed the battery on two separate occasions. Reliability estimates for the individual tasks ranged from moderate to high, with Pearson correlations within the specific impulsivity domains as follows: impulsive choice (r = .76 - .89, ps < .001); impulsive action (r = .65 - .73, ps < .001); and inattention (r = .38-.42, ps < .001). Additionally, the influence of day-to-day fluctuations in mood as measured by the Profile of Mood States was assessed in relation to variability in performance on each of the behavioral tasks. Change in performance on the delay discounting task was significantly associated with change in positive mood and arousal. No other behavioral measures were significantly associated with mood. In sum, the current analysis demonstrates that behavioral measures of impulsivity are reliable measures and thus can be confidently used to assess various facets of impulsivity as intermediate phenotypes for drug abuse. PMID:24099351

  5. Microfluidic nitrogen-assisted nanoelectrospray emitter: A monolithic interface for accurate mass measurements based on a single nozzle.

    PubMed

    Wang, Lingling; Wang, Yujiao; Jiang, Shichang; Ye, Mingyue; Su, Ping; Xiong, Bo

    2016-10-28

    Nitrogen-assisted nanoelectrospray emitter (NANE) was developed to achieve accurate mass-to-charge ratio (m/z) measurements with a single monolithic nozzle. Deposition patterns of generated electrosprays from NANE confirmed their wrapped configurations. Additionally, the intensity of the sample ion and its ratio relative to a reference ion was inclined to focus on the central region of the spray; this trend further supported the existence of wrapped configurations. Further, the proposed NANE was fabricated from poly-(dimethylsiloxane) (PDMS) with octadecyltrichlorosilane modification to restrain the dissolution of PDMS monomers. Assist nitrogen flows were introduced to improve the ionization of reference ions. Moreover, the NANE could regulate the distribution of reference ions by microfluidic three dimensional hydrodynamic focusing. By regulating the distribution of reference ions, the ionization depression was reduced to some degree, and an improved sensitivity was accomplished compared with the mixing of sample and reference solutions. Achieved relative errors of m/z were between 0.2-4.5ppm and 5.2-9.2ppm for ten organic molecules and four biological macromolecules, respectively. Acceptable linear ranges were obtained in quantifications for rhodamine B and emamectin benzoate. Finally, the NANE was compatible with broad infusion rates (from 50nLmin -1 to 15μLmin -1 ) and solutions of different compositions (from 100% methanol to 100% water). Considering the comprehensive application of PDMS in microfluidics, the proposed NANE could be used as a compact and monolithic interface to achieve accurate m/z measurements. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Observation procedure, observer gender, and behavior valence as determinants of sampling error in a behavior assessment analogue

    PubMed Central

    Farkas, Gary M.; Tharp, Roland G.

    1980-01-01

    Several factors thought to influence the representativeness of behavioral assessment data were examined in an analogue study using a multifactorial design. Systematic and unsystematic methods of observing group behavior were investigated using 18 male and 18 female observers. Additionally, valence properties of the observed behaviors were inspected. Observers' assessments of a videotape were compared to a criterion code that defined the population of behaviors. Results indicated that systematic observation procedures were more accurate than unsystematic procedures, though this factor interacted with gender of observer and valence of behavior. Additionally, males tended to sample more representatively than females. A third finding indicated that the negatively valenced behavior was overestimated, whereas the neutral and positively valenced behaviors were accurately assessed. PMID:16795631

  7. Patient-Centeredness as Physician Behavioral Adaptability to Patient Preferences.

    PubMed

    Carrard, Valérie; Schmid Mast, Marianne; Jaunin-Stalder, Nicole; Junod Perron, Noëlle; Sommer, Johanna

    2018-05-01

    A physician who communicates in a patient-centered way is a physician who adapts his or her communication style to what each patient needs. In order to do so, the physician has to (1) accurately assess each patient's states and traits (interpersonal accuracy) and (2) possess a behavioral repertoire to choose from in order to actually adapt his or her behavior to different patients (behavioral adaptability). Physician behavioral adaptability describes the change in verbal or nonverbal behavior a physician shows when interacting with patients who have different preferences in terms of how the physician should interact with them. We hypothesized that physician behavioral adaptability to their patients' preferences would lead to better patient outcomes and that physician interpersonal accuracy was positively related to behavioral adaptability. To test these hypotheses, we recruited 61 physicians who completed an interpersonal accuracy test before being videotaped during four consultations with different patients. The 244 participating patients indicated their preferences for their physician's interaction style prior to the consultation and filled in a consultation outcomes questionnaire directly after the consultation. We coded the physician's verbal and nonverbal behavior for each of the consultations and compared it to the patients' preferences to obtain a measure of physician behavioral adaptability. Results partially confirmed our hypotheses in that female physicians who adapted their nonverbal (but not their verbal) behavior had patients who reported more positive consultation outcomes. Moreover, the more female physicians were accurate interpersonally, the more they showed verbal and nonverbal behavioral adaptability. For male physicians, more interpersonal accuracy was linked to less nonverbal adaptability.

  8. Using machine learning and surface reconstruction to accurately differentiate different trajectories of mood and energy dysregulation in youth.

    PubMed

    Versace, Amelia; Sharma, Vinod; Bertocci, Michele A; Bebko, Genna; Iyengar, Satish; Dwojak, Amanda; Bonar, Lisa; Perlman, Susan B; Schirda, Claudiu; Travis, Michael; Gill, Mary Kay; Diwadkar, Vaibhav A; Sunshine, Jeffrey L; Holland, Scott K; Kowatch, Robert A; Birmaher, Boris; Axelson, David; Frazier, Thomas W; Arnold, L Eugene; Fristad, Mary A; Youngstrom, Eric A; Horwitz, Sarah M; Findling, Robert L; Phillips, Mary L

    2017-01-01

    Difficulty regulating positive mood and energy is a feature that cuts across different pediatric psychiatric disorders. Yet, little is known regarding the neural mechanisms underlying different developmental trajectories of positive mood and energy regulation in youth. Recent studies indicate that machine learning techniques can help elucidate the role of neuroimaging measures in classifying individual subjects by specific symptom trajectory. Cortical thickness measures were extracted in sixty-eight anatomical regions covering the entire brain in 115 participants from the Longitudinal Assessment of Manic Symptoms (LAMS) study and 31 healthy comparison youth (12.5 y/o;-Male/Female = 15/16;-IQ = 104;-Right/Left handedness = 24/5). Using a combination of trajectories analyses, surface reconstruction, and machine learning techniques, the present study aims to identify the extent to which measures of cortical thickness can accurately distinguish youth with higher (n = 18) from those with lower (n = 34) trajectories of manic-like behaviors in a large sample of LAMS youth (n = 115; 13.6 y/o; M/F = 68/47, IQ = 100.1, R/L = 108/7). Machine learning analyses revealed that widespread cortical thickening in portions of the left dorsolateral prefrontal cortex, right inferior and middle temporal gyrus, bilateral precuneus, and bilateral paracentral gyri and cortical thinning in portions of the right dorsolateral prefrontal cortex, left ventrolateral prefrontal cortex, and right parahippocampal gyrus accurately differentiate (Area Under Curve = 0.89;p = 0.03) youth with different (higher vs lower) trajectories of positive mood and energy dysregulation over a period up to 5years, as measured by the Parent General Behavior Inventory-10 Item Mania Scale. Our findings suggest that specific patterns of cortical thickness may reflect transdiagnostic neural mechanisms associated with different temporal trajectories of positive mood and energy dysregulation in youth. This approach has

  9. An algorithm for selecting the most accurate protocol for contact angle measurement by drop shape analysis.

    PubMed

    Xu, Z N

    2014-12-01

    In this study, an error analysis is performed to study real water drop images and the corresponding numerically generated water drop profiles for three widely used static contact angle algorithms: the circle- and ellipse-fitting algorithms and the axisymmetric drop shape analysis-profile (ADSA-P) algorithm. The results demonstrate the accuracy of the numerically generated drop profiles based on the Laplace equation. A significant number of water drop profiles with different volumes, contact angles, and noise levels are generated, and the influences of the three factors on the accuracies of the three algorithms are systematically investigated. The results reveal that the above-mentioned three algorithms are complementary. In fact, the circle- and ellipse-fitting algorithms show low errors and are highly resistant to noise for water drops with small/medium volumes and contact angles, while for water drop with large volumes and contact angles just the ADSA-P algorithm can meet accuracy requirement. However, this algorithm introduces significant errors in the case of small volumes and contact angles because of its high sensitivity to noise. The critical water drop volumes of the circle- and ellipse-fitting algorithms corresponding to a certain contact angle error are obtained through a significant amount of computation. To improve the precision of the static contact angle measurement, a more accurate algorithm based on a combination of the three algorithms is proposed. Following a systematic investigation, the algorithm selection rule is described in detail, while maintaining the advantages of the three algorithms and overcoming their deficiencies. In general, static contact angles over the entire hydrophobicity range can be accurately evaluated using the proposed algorithm. The ease of erroneous judgment in static contact angle measurements is avoided. The proposed algorithm is validated by a static contact angle evaluation of real and numerically generated water drop

  10. Development of an attachment-informed measure of sexual behavior in late adolescence.

    PubMed

    Szielasko, Alicia L; Symons, Douglas K; Lisa Price, E

    2013-04-01

    There is considerable interest in relations between sexual behavior and romantic attachment styles in adolescence as attachment needs are increasingly met through intimate partners rather than parents. The objectives of this research were to organize a measure of sexual behavior within an attachment theory framework, and then show that this new measure uniquely predicted sexual approach styles and invasive sexual experiences. 190 18- and 19-year-old university students in late adolescence completed sexual behavior items that were provided ambivalent (anxious) and avoidant dimensions. These were systematically related to the romantic attachment dimensions of the Experiences in Close Relationships - Revised. However, even after romantic relationship style, gender, and social desirability were controlled, avoidance in sexual relationships predicted lifetime sexual partner number and negatively predicted positive sexual strategies, and ambivalence in sexual relationships predicted invasive and coercive sexual behaviors. A measure specific to sexual relationships informs the attachment and romantic context of sex in late adolescence. Copyright © 2013 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.

  11. A systematic approach for the accurate and rapid measurement of water vapor transmission through ultra-high barrier films

    NASA Astrophysics Data System (ADS)

    Kiese, Sandra; Kücükpinar, Esra; Reinelt, Matthias; Miesbauer, Oliver; Ewender, Johann; Langowski, Horst-Christian

    2017-02-01

    Flexible organic electronic devices are often protected from degradation by encapsulation in multilayered films with very high barrier properties against moisture and oxygen. However, metrology must be improved to detect such low quantities of permeants. We therefore developed a modified ultra-low permeation measurement device based on a constant-flow carrier-gas system to measure both the transient and stationary water vapor permeation through high-performance barrier films. The accumulation of permeated water vapor before its transport to the detector allows the measurement of very low water vapor transmission rates (WVTRs) down to 2 × 10-5 g m-2 d-1. The measurement cells are stored in a temperature-controlled chamber, allowing WVTR measurements within the temperature range 23-80 °C. Differences in relative humidity can be controlled within the range 15%-90%. The WVTR values determined using the novel measurement device agree with those measured using a commercially available carrier-gas device from MOCON®. Depending on the structure and quality of the barrier film, it may take a long time for the WVTR to reach a steady-state value. However, by using a combination of the time-dependent measurement and the finite element method, we were able to estimate the steady-state WVTR accurately with significantly shorter measurement times.

  12. Development and validation of the Pediatric Anesthesia Behavior score--an objective measure of behavior during induction of anesthesia.

    PubMed

    Beringer, Richard M; Greenwood, Rosemary; Kilpatrick, Nicky

    2014-02-01

    Measuring perioperative behavior changes requires validated objective rating scales. We developed a simple score for children's behavior during induction of anesthesia (Pediatric Anesthesia Behavior score) and assessed its reliability, concurrent validity, and predictive validity. Data were collected as part of a wider observational study of perioperative behavior changes in children undergoing general anesthesia for elective dental extractions. One-hundred and two healthy children aged 2-12 were recruited. Previously validated behavioral scales were used as follows: the modified Yale Preoperative Anxiety Scale (m-YPAS); the induction compliance checklist (ICC); the Pediatric Anesthesia Emergence Delirium scale (PAED); and the Post-Hospitalization Behavior Questionnaire (PHBQ). Pediatric Anesthesia Behavior (PAB) score was independently measured by two investigators, to allow assessment of interobserver reliability. Concurrent validity was assessed by examining the correlation between the PAB score, the m-YPAS, and the ICC. Predictive validity was assessed by examining the association between the PAB score, the PAED scale, and the PHBQ. The PAB score correlated strongly with both the m-YPAS (P < 0.001) and the ICC (P < 0.001). PAB score was significantly associated with the PAED score (P = 0.031) and with the PHBQ (P = 0.034). Two independent investigators recorded identical PAB scores for 94% of children and overall, there was close agreement between scores (Kappa coefficient of 0.886 [P < 0.001]). The PAB score is simple to use and may predict which children are at increased risk of developing postoperative behavioral disturbance. This study provides evidence for its reliability and validity. © 2013 John Wiley & Sons Ltd.

  13. New device for accurate measurement of the x-ray intensity distribution of x-ray tube focal spots.

    PubMed

    Doi, K; Fromes, B; Rossmann, K

    1975-01-01

    A new device has been developed with which the focal spot distribution can be measured accurately. The alignment and localization of the focal spot relative to the device are accomplished by adjustment of three micrometer screws in three orthogonal directions and by comparison of red reference light spots with green fluorescent pinhole images at five locations. The standard deviations for evaluating the reproducibility of the adjustments in the horizontal and vertical directions were 0.2 and 0.5 mm, respectively. Measurements were made of the pinhole images as well as of the line-spread functions (LSFs) and modulation transfer functions (MTFs) for an x-ray tube with focal spots of 1-mm and 50-mum nominal size. The standard deviations for the LSF and MTF of the 1-mm focal spot were 0.017 and 0.010, respectively.

  14. Risk perception measures' associations with behavior intentions, affect, and cognition following colon cancer screening messages.

    PubMed

    Dillard, Amanda J; Ferrer, Rebecca A; Ubel, Peter A; Fagerlin, Angela

    2012-01-01

    Risk perception is important for motivating health behavior (e.g., Janz & Becker, 1984), but different measures of the construct may change how important that relationship appears. In two studies, we examined associations between four measures of risk perception, health behavior intentions and possible behavioral determinants. Participants in these studies, who were due for colorectal cancer screening, read an online message about the importance of screening to reduce the chance of cancer. We examined bivariate and multivariate associations between risk perception measures, including absolute, comparative, and feelings-of-risk, and behavioral intentions to screen, general worry, and knowledge and attitudes related to screening. Results across the two studies were consistent, with all risk perception measures being correlated with intentions and attitudes. Multivariate analyses revealed that feelings-of-risk was most predictive of all variables, with the exception of general worry, for which comparative measures were the most predictive. Researchers interested in risk perception should assess feelings-of-risk along with more traditional measures. Those interested in influencing health behavior specifically should attempt to increase feelings of vulnerability rather than numerical risk.

  15. Behavioral Economic Measures of Alcohol Reward Value as Problem Severity Indicators in College Students

    PubMed Central

    Skidmore, Jessica R.; Murphy, James G.; Martens, Matthew P.

    2014-01-01

    The aims of the current study were to examine the associations among behavioral economic measures of alcohol value derived from three distinct measurement approaches, and to evaluate their respective relations with traditional indicators of alcohol problem severity in college drinkers. Five behavioral economic metrics were derived from hypothetical demand curves that quantify reward value by plotting consumption and expenditures as a function of price, another metric measured proportional behavioral allocation and enjoyment related to alcohol versus other activities, and a final metric measured relative discretionary expenditures on alcohol. The sample included 207 heavy drinking college students (53% female) who were recruited through an on-campus health center or university courses. Factor analysis revealed that the alcohol valuation construct comprises two factors: one factor that reflects participants’ levels of alcohol price sensitivity (demand persistence), and a second factor that reflects participants’ maximum consumption and monetary and behavioral allocation towards alcohol (amplitude of demand). The demand persistence and behavioral allocation metrics demonstrated the strongest and most consistent multivariate relations with alcohol-related problems, even when controlling for other well-established predictors. The results suggest that behavioral economic indices of reward value show meaningful relations with alcohol problem severity in young adults. Despite the presence of some gender differences, these measures appear to be useful problem indicators for men and women. PMID:24749779

  16. Accurate Black Hole Spin Measurements using ABC

    NASA Astrophysics Data System (ADS)

    Connolly, Andrew

    Measuring the spin of black holes provides important insights into the supernova formation mechanism of stellar-mass black holes, galaxy merger scenarios for supermassive black holes, and the launching mechanisms of ballistic jets. It is therefore of crucial importance to measure black hole spins to a high degree of accuracy. Stellar-mass black holes in binary systems (BHBs) have two major advantages over Active Galactic Nuclei (AGN): (1) owing to their proximity and brightness, observations of BHBs are not as limited by counting statistics as their supermassive counter-parts; (2) unlike in AGN, one can use two largely independent methods to measure the spin in BHBs, providing a check on spin measurements. However, the high flux that makes BHBs such excellent targets for spin measurements also proves to be their Achilles heel: modern CCD cameras are optimized for observing faint sources. Consequently, observations of bright BHBs with CCD cameras are subject to non-linear instrumental effects among them pile-up and grade migration that strongly distort the spectrum. Since spin measurements rely on a very precise model of both the continuum X-ray flux and disc reflection signatures superimposed on top of the former, these instrumental effects may cause inferred spin measurements to differ by a factor of two or more. Current mitigation strategies are aimed at removing instrumental effects either during the observations themselves, by requiring simultaneous observations with multiple telescopes, or in post-processing. Even when these techniques are employed, pile-up may remain unrecognized and still distort results, whereas mitigation strategies may introduce additional systematic biases, e.g. due to increased (cross-)calibration uncertainties. Advances in modern statistical methodology allow for efficient modeling of instrumental effects during the analysis stage, largely eliminating the requirements for observations with multiple instruments or increased observation

  17. High frequency measures of OHC nonlinear capacitance (NLC) and their significance: Why measures stray away from predictions

    NASA Astrophysics Data System (ADS)

    Santos-Sacchi, Joseph

    2018-05-01

    Measures of membrane capacitance (Cm) can be used to assess important characteristics of voltage-dependent membrane proteins (e.g., channels and transporters). In particular, a protein's time-dependent voltage-sensor charge movement is equivalently represented as a frequency-dependent component of Cm, telling much about the kinetics of the protein's conformational behavior. Recently, we have explored the frequency dependence of OHC voltage-dependent capacitance (aka nonlinear capacitance, NLC) to query rates of conformational switching within prestin (SLC26a5), the cell's lateral membrane molecular motor 1. Following removal of confounding stray capacitance effects, high frequency Cm measures using wide-band stimuli accurately reveal unexpected low pass behavior in prestin's molecular motions.

  18. Test-retest reliability of behavioral measures of impulsive choice, impulsive action, and inattention.

    PubMed

    Weafer, Jessica; Baggott, Matthew J; de Wit, Harriet

    2013-12-01

    Behavioral measures of impulsivity are widely used in substance abuse research, yet relatively little attention has been devoted to establishing their psychometric properties, especially their reliability over repeated administration. The current study examined the test-retest reliability of a battery of standardized behavioral impulsivity tasks, including measures of impulsive choice (i.e., delay discounting, probability discounting, and the Balloon Analogue Risk Task), impulsive action (i.e., the stop signal task, the go/no-go task, and commission errors on the continuous performance task), and inattention (i.e., attention lapses on a simple reaction time task and omission errors on the continuous performance task). Healthy adults (n = 128) performed the battery on two separate occasions. Reliability estimates for the individual tasks ranged from moderate to high, with Pearson correlations within the specific impulsivity domains as follows: impulsive choice (r range: .76-.89, ps < .001); impulsive action (r range: .65-.73, ps < .001); and inattention (r range: .38-.42, ps < .001). Additionally, the influence of day-to-day fluctuations in mood, as measured by the Profile of Mood States, was assessed in relation to variability in performance on each of the behavioral tasks. Change in performance on the delay discounting task was significantly associated with change in positive mood and arousal. No other behavioral measures were significantly associated with mood. In sum, the current analysis demonstrates that behavioral measures of impulsivity are reliable measures and thus can be confidently used to assess various facets of impulsivity as intermediate phenotypes for drug abuse.

  19. Item response theory and the measurement of motor behavior.

    PubMed

    Safrit, M J; Cohen, A S; Costa, M G

    1989-12-01

    Item response theory (IRT) has been the focus of intense research and development activity in educational and psychological measurement during the past decade. Because this theory can provide more precise information about test items than other theories usually used in measuring motor behavior, the application of IRT in physical education and exercise science merits investigation. In IRT, the difficulty level of each item (e.g., trial or task) can be estimated and placed on the same scale as the ability of the examinee. Using this information, the test developer can determine the ability levels at which the test functions best. Equating the scores of individuals on two or more items or tests can be handled efficiently by applying IRT. The precision of the identification of performance standards in a mastery test context can be enhanced, as can adaptive testing procedures. In this tutorial, several potential benefits of applying IRT to the measurement of motor behavior were described. An example is provided using bowling data and applying the graded-response form of the Rasch IRT model. The data were calibrated and the goodness of fit was examined. This analysis is described in a step-by-step approach. Limitations to using an IRT model with a test consisting of repeated measures were noted.

  20. Symbolic dynamic filtering and language measure for behavior identification of mobile robots.

    PubMed

    Mallapragada, Goutham; Ray, Asok; Jin, Xin

    2012-06-01

    This paper presents a procedure for behavior identification of mobile robots, which requires limited or no domain knowledge of the underlying process. While the features of robot behavior are extracted by symbolic dynamic filtering of the observed time series, the behavior patterns are classified based on language measure theory. The behavior identification procedure has been experimentally validated on a networked robotic test bed by comparison with commonly used tools, namely, principal component analysis for feature extraction and Bayesian risk analysis for pattern classification.

  1. Behavioral Objectives for English

    ERIC Educational Resources Information Center

    Zoellner, Robert

    1972-01-01

    A review-critique of On Writing Behavioral Objectives for English, by John Maxwell and Anthony Lovat, in which behavioral objectives theory is dominated by a stimulus-response rather than a stimulus-response-reinforcement psychology. The reviewer questions whether behavioral objectives can be applied accurately and without distortion of meanings,…

  2. Taking Stock of Behavioral Measures of Adolescent Dating Violence

    PubMed Central

    SMITH, JACLYN; MULFORD, CARRIE; LATZMAN, NATASHA E.; THARP, ANDRA TETEN; NIOLON, PHYLLIS HOLDITCH; BLACHMAN-DEMNER, DARA

    2018-01-01

    The past 2 decades have witnessed an increase in dating violence awareness and research. As the field evolves, it is critical to examine the definition and measurement of adolescent dating violence. This article summarizes the behavioral measures of adolescent dating violence used in the field. Based on a review of the literature and federally funded studies, we identified 48 different measures. The most commonly used measures were the Conflict Tactics Scale–2, the Safe Dates Scale, and the Conflict in Adolescent Dating Relationship Inventory, which all examine aspects of psychological, physical, and sexual violence. Researchers also adapted or created their own measures. This article concludes with a discussion of developments for consideration as the field moves forward. PMID:29606849

  3. Amotivation in Schizophrenia: Integrated Assessment With Behavioral, Clinical, and Imaging Measures

    PubMed Central

    Wolf, Daniel H.; Satterthwaite, Theodore D.; Kantrowitz, Jacob J.; Katchmar, Natalie; Vandekar, Lillie; Elliott, Mark A.; Ruparel, Kosha

    2014-01-01

    Motivational deficits play a central role in disability caused by schizophrenia and constitute a major unmet therapeutic need. Negative symptoms have previously been linked to hypofunction in ventral striatum (VS), a core component of brain motivation circuitry. However, it remains unclear to what extent this relationship holds for specific negative symptoms such as amotivation, and this question has not been addressed with integrated behavioral, clinical, and imaging measures. Here, 41 individuals with schizophrenia and 37 controls performed a brief, computerized progressive ratio task (PRT) that quantifies effort exerted in pursuit of monetary reward. Clinical amotivation was assessed using the recently validated Clinical Assessment Interview for Negative Symptoms (CAINS). VS function was probed during functional magnetic resonance imaging using a monetary guessing paradigm. We found that individuals with schizophrenia had diminished motivation as measured by the PRT, which significantly and selectively related to clinical amotivation as measured by the CAINS. Critically, lower PRT motivation in schizophrenia was also dimensionally related to VS hypofunction. Our results demonstrate robust dimensional associations between behavioral amotivation, clinical amotivation, and VS hypofunction in schizophrenia. Integrating behavioral measures such as the PRT will facilitate translational efforts to identify biomarkers of amotivation and to assess response to novel therapeutic interventions. PMID:24657876

  4. A measure of fall risk behaviors and perceptions among community-dwelling older adults.

    PubMed

    Yuen, Hon Keung; Carter, Rickey E

    2006-01-01

    Relatively little is known about the interaction between behavioral and environmental circumstances associated with falls among community-dwelling older adults. This study is designed to develop an instrument that measures community-dwelling older adults' participation in and perceptions of fall risk behaviors. Eighty-seven community-dwelling older adults aged 60 or above (mean +/- SD = 76 +/- 7.9), who had experienced at least one fall in the past 12 months, completed a questionnaire dealing with frequency of their participation in fall risk behaviors, their perceptions of these behaviors, and their fall history. Data were subjected to exploratory factor analysis. A 20-item instrument consisting of three constructs was presented as the Fall Risk Behaviors and Perceptions Scale (FRB&PS). Two of the three constructs of the instrument were de-stabilizers and non-supports, both of which measure participation in fall risk behaviors; the third was perceptions of fall risk behaviors. Internal consistency coefficient of the FRB&PS is 0.733 with a root mean square error of approximation (RMSEA) score of 0.075, which indicates an adequate model fit. Results from the stepwise regression analyses indicated that adults aged 75 and above (the old-old) participated less frequently in fall risk activities (p = 0.025), and had more knowledge about fall risks as measured by a higher perception score (p = 0.025) than those aged 60 to 75 (the young-old). Older men tended to participate more frequently in fall risk activities (p = 0.020) than older women; in addition, those older adults who are more mobile (p = 0.002) also participated more frequently in fall risk behaviors than those who are less mobile. Preliminary findings indicate that the pilot FRB&PS is a reliable and valid instrument to measure community-dwelling older adults' participation in and perceptions of fall risk behaviors. Additional psychometric validation of the FRB&PS on predicting the likelihood of falls is

  5. Advancing Measurement of Locomotor Rehabilitation Outcomes to Optimize Interventions and Differentiate between Recovery versus Compensation

    PubMed Central

    Bowden, Mark G.; Behrman, Andrea L.; Woodbury, Michelle; Gregory, Chris M.; Velozo, Craig A.; Kautz, Steven A.

    2017-01-01

    Progress in locomotor rehabilitation has created an increasing need to understand the factors that contribute to motor behavior, to determine whether these factors are modifiable, and if so, to determine how best to modify them in a way that promotes improved function. Currently available measures do not have the capacity to distinguish between neuromotor recovery and compensation for impaired underlying body structure/functions. The purpose of this Special Interest article is to examine the state of outcomes measurement in physical therapy in regards outcomes to locomotor rehabilitation, and to suggest approaches that may improve assessment of recovery and clinical decision-making capabilities. We examine historical approaches to measurement of locomotor rehabilitation outcomes including rating scales, timed movement tasks, and laboratory-based outcome measures, and we discuss the emerging use of portable technology to assess walking in a free living environment. The ability to accurately measure outcomes of rehabilitation, both in and away from the laboratory setting, allows assessment of skill acquisition, retention, and long-term carryover in a variety of environments. Accurate measurement allows behavioral changes to be observed and assessments to be made, not only regarding an individual's ability to adapt during interventions, but also their ability to incorporate new skills into a real-world behavior. The result of such an approach to assessment may be that interventions truly translate from laboratory to real-world environments. Future locomotor measurement tools must be based on a theoretical framework that can guide their use to accurately quantify treatment effects and provide a basis upon which to develop and refine therapeutic interventions. PMID:22333921

  6. Measurement of assertive behavior: construct and predictive validity of self-report, role-playing, and in-vivo measures.

    PubMed

    Burkhart, B R; Green, S B; Harrison, W H

    1979-04-01

    Examined the predictive validity and construct equivalence of the three major procedures used to measure assertive behavior: Self-report, behavioral role-playing, and in-vivo assessment. Seventy-five Ss, who spanned the range of assertiveness, completed two self-report measures of assertiveness, the Rathus Assertiveness Scale (RAS) and the College Self-Expression Scale (CSES); two scales from the Endler S-R Inventory of General Trait Anxiousness, the interpersonal and general anxiety scales; eight role-playing situations that involved the expression of positive and negative assertiveness; and a telephone in-vivo task. In general, the study revealed the following: (1) assertiveness measures are task-dependent in that there was more overlap within task than between tasks; (2) there is a moderate degree of correspondence between self-report and role-playing measures, although this was true only for negative assertion; (3) positive and negative assertion do not appear to have the same topography of responding; and (4) there appears to be no consistent relationship between the in-vivo measure and any other type of assertiveness measure.

  7. Measured and predicted structural behavior of the HiMAT tailored composite wing

    NASA Technical Reports Server (NTRS)

    Nelson, Lawrence H.

    1987-01-01

    A series of load tests was conducted on the HiMAT tailored composite wing. Coupon tests were also run on a series of unbalanced laminates, including the ply configuration of the wing, the purpose of which was to compare the measured and predicted behavior of unbalanced laminates, including - in the case of the wing - a comparison between the behavior of the full scale structure and coupon tests. Both linear and nonlinear finite element (NASTRAN) analyses were carried out on the wing. Both linear and nonlinear point-stress analyses were performed on the coupons. All test articles were instrumented with strain gages, and wing deflections measured. The leading and trailing edges were found to have no effect on the response of the wing to applied loads. A decrease in the stiffness of the wing box was evident over the 27-test program. The measured load-strain behavior of the wing was found to be linear, in contrast to coupon tests of the same laminate, which were nonlinear. A linear NASTRAN analysis of the wing generally correlated more favorably with measurements than did a nonlinear analysis. An examination of the predicted deflections in the wing root region revealed an anomalous behavior of the structural model that cannot be explained. Both hysteresis and creep appear to be less significant in the wing tests than in the corresponding laminate coupon tests.

  8. Accurate measurements of cross-plane thermal conductivity of thin films by dual-frequency time-domain thermoreflectance (TDTR)

    NASA Astrophysics Data System (ADS)

    Jiang, Puqing; Huang, Bin; Koh, Yee Kan

    2016-07-01

    Accurate measurements of the cross-plane thermal conductivity Λcross of a high-thermal-conductivity thin film on a low-thermal-conductivity (Λs) substrate (e.g., Λcross/Λs > 20) are challenging, due to the low thermal resistance of the thin film compared with that of the substrate. In principle, Λcross could be measured by time-domain thermoreflectance (TDTR), using a high modulation frequency fh and a large laser spot size. However, with one TDTR measurement at fh, the uncertainty of the TDTR measurement is usually high due to low sensitivity of TDTR signals to Λcross and high sensitivity to the thickness hAl of Al transducer deposited on the sample for TDTR measurements. We observe that in most TDTR measurements, the sensitivity to hAl only depends weakly on the modulation frequency f. Thus, we performed an additional TDTR measurement at a low modulation frequency f0, such that the sensitivity to hAl is comparable but the sensitivity to Λcross is near zero. We then analyze the ratio of the TDTR signals at fh to that at f0, and thus significantly improve the accuracy of our Λcross measurements. As a demonstration of the dual-frequency approach, we measured the cross-plane thermal conductivity of a 400-nm-thick nickel-iron alloy film and a 3-μm-thick Cu film, both with an accuracy of ˜10%. The dual-frequency TDTR approach is useful for future studies of thin films.

  9. Development of a measure of college students' adherence to religious doctrine concerning sexual behavior.

    PubMed

    Victor, Elizabeth C; Bowman, Hilary; Thompson, Robert J

    2015-01-01

    The authors developed a 14-item measure of adherence to religious doctrine concerning sexual behavior (ARDSB). The ARDSB psychometric properties were investigated to better understand religious motivations associated with changes in sexual behavior that may provide support for sexual health promotion and prevention programs. Four hundred eighty-three undergraduates aged 18 to 26. Data were collected from an online survey during the 2012-2013 academic school year. Principle components factor analysis identified 2 factors: reasons to break religious doctrine and reasons to adhere to religious doctrine concerning sexual behavior. The subscales had good internal consistency. Correlations, t tests, and analyses of variance of the subscales with measures of intrinsic and extrinsic religiosity and self-reported sexual behavior and risk provide support for concurrent validity. The ARDSB could be employed as a measure to better understand sexual behavior; it is inexpensive and relatively easy to employ in both research and campus ministry settings.

  10. Accurate reconstruction of the jV-characteristic of organic solar cells from measurements of the external quantum efficiency

    NASA Astrophysics Data System (ADS)

    Meyer, Toni; Körner, Christian; Vandewal, Koen; Leo, Karl

    2018-04-01

    In two terminal tandem solar cells, the current density - voltage (jV) characteristic of the individual subcells is typically not directly measurable, but often required for a rigorous device characterization. In this work, we reconstruct the jV-characteristic of organic solar cells from measurements of the external quantum efficiency under applied bias voltages and illumination. We show that it is necessary to perform a bias irradiance variation at each voltage and subsequently conduct a mathematical correction of the differential to the absolute external quantum efficiency to obtain an accurate jV-characteristic. Furthermore, we show that measuring the external quantum efficiency as a function of voltage for a single bias irradiance of 0.36 AM1.5g equivalent sun provides a good approximation of the photocurrent density over voltage curve. The method is tested on a selection of efficient, common single-junctions. The obtained conclusions can easily be transferred to multi-junction devices with serially connected subcells.

  11. Evaluation of factors affecting accurate measurements of atmospheric CO2 and CH4 by wavelength-scanned cavity ring-down spectroscopy

    NASA Astrophysics Data System (ADS)

    Nara, H.; Tanimoto, H.; Tohjima, Y.; Mukai, H.; Nojiri, Y.; Katsumata, K.; Rella, C.

    2012-07-01

    We examined potential interferences from water vapor and atmospheric background gases (N2, O2, and Ar), and biases by isotopologues of target species, on accurate measurement of atmospheric CO2 and CH4 by means of wavelength-scanned cavity ring-down spectroscopy (WS-CRDS). Variations in the composition of the background gas substantially impacted the CO2 and CH4 measurements: the measured amounts of CO2 and CH4 decreased with increasing N2 mole fraction, but increased with increasing O2 and Ar, suggesting that the pressure-broadening effects (PBEs) increased as Ar < O2 < N2. Using these experimental results, we inferred PBEs for the measurement of synthetic standard gases. The PBEs were negligible (up to 0.05 ppm for CO2 and 0.01 ppb for CH4) for gas standards balanced with purified air, although the PBEs were substantial (up to 0.87 ppm for CO2 and 1.4 ppb for CH4) for standards balanced with synthetic air. For isotopic biases on CO2 measurements, we compared experimental results and theoretical calculations, which showed excellent agreement within their uncertainty. We derived empirical correction functions for water vapor for three WS-CRDS instruments (Picarro EnviroSense 3000i, G-1301, and G-2301). Although the transferability of the functions was not clear, no significant difference was found in the water vapor correction values among these instruments within the typical analytical precision at sufficiently low water concentrations (< 0.3%V for CO2 and < 0.4%V for CH4). For accurate measurements of CO2 and CH4 in ambient air, we concluded that WS-CRDS measurements should be performed under complete dehumidification of air samples, or moderate dehumidification followed by application of a water vapor correction function, along with calibration by natural air-based standard gases or purified air-balanced synthetic standard gases with isotopic correction.

  12. A new multidimensional measure of African adolescents' perceptions of teachers' behaviors.

    PubMed

    Mboya, M M

    1994-04-01

    The Perceived Teacher Behavior Inventory was designed to measure three dimensions of students' perceptions of the behaviors of their teachers. This research was conducted to assess the statistical validity and reliability of the instrument administered to 770 students attending two coeducational high schools in Cape Town, South Africa. Factor analysis clearly identified three subscales indicating that the instrument distinguished the students' perceptions of their teachers' behaviors in three areas. Estimates of internal consistency of the subscales were assessed using the squared multiple correlation as the index of reliability.

  13. Accurate viscosity measurements of flowing aqueous glucose solutions with suspended scatterers using a dynamic light scattering approach with optical coherence tomography.

    PubMed

    Weatherbee, Andrew; Popov, Ivan; Vitkin, Alex

    2017-08-01

    The viscosity of turbid colloidal glucose solutions has been accurately determined from spectral domain optical coherence tomography (OCT) M-mode measurements and our recently developed OCT dynamic light scattering model. Results for various glucose concentrations, flow speeds, and flow angles are reported. The relative "combined standard uncertainty" uc(η) on the viscosity measurements was ±1% for the no-flow case and ±5% for the flow cases, a significant improvement in measurement robustness over previously published reports. The available literature data for the viscosity of pure water and our measurements differ by 1% (stagnant case) and 1.5% (flow cases), demonstrating good accuracy; similar agreement is seen across the measured glucose concentration range when compared to interpolated literature values. The developed technique may contribute toward eventual noninvasive glucose measurements in medicine. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  14. Psychosocial Factors and AIDS-Related Behavior of Homosexual Men: Measurement and Associations.

    ERIC Educational Resources Information Center

    Zapka, Jane G.; And Others

    1990-01-01

    Measurement and data-reduction procedures were conducted for psychosocial scales used in behavioral research on the acquired immune deficiency syndrome (AIDS). Associations of the scales for other personal and health services/information factors with one selected AIDS protective behavior among 281 asymptomatic homosexual/bisexual men were…

  15. Using Teach-Back to Understand Participant Behavioral Self-Monitoring Skills Across Health Literacy Level and Behavioral Condition.

    PubMed

    Porter, Kathleen; Chen, Yvonnes; Estabrooks, Paul; Noel, Lauren; Bailey, Angela; Zoellner, Jamie

    2016-01-01

    To assess differences, by health literacy status and behavioral condition, in participants' abilities to self-monitor behaviors accurately and recall key behavioral messages using data from a teach-back call. Cross-sectional. Rural, southwestern Virginia. Adults (n = 301). The majority were female (81.1%), 31.9% had a high school education or less, 66.1% earned < $25,000/y, and 32.9% were low health literate. First class session of 2 community-based behavioral interventions: SIPsmartER (reduce sugar-sweetened beverage intake) or MoveMore (increase physical activity). Reported accuracy of behavioral diary completion, proportion of behavioral messages recalled during the first round of teach-back, and rounds of teach-back. Descriptive statistics and generalized linear model. Low health literate participants were significantly less accurate in diary completion (P < .001), recalled fewer behavioral messages correctly (P < .001), and needed more rounds of teach-back (P < .001) than high health literate participants. Compared with SIPsmartER participants, MoveMore participants more accurately completed diaries (P = .001) but recalled a lower proportion of behavioral messages correctly (P < .001) and required more rounds of teach-back (P < .001). Health literacy status and behavioral target affect the ability to self-monitor and recall key concepts. Researchers should consider using teach-back early in the intervention to assess and reinforce participants' ability to self-monitor. Copyright © 2016 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  16. Use of quality measures for Medicaid behavioral health services by state agencies: implications for health care reform.

    PubMed

    Seibert, Julie; Fields, Suzanne; Fullerton, Catherine Anne; Mark, Tami L; Malkani, Sabrina; Walsh, Christine; Ehrlich, Emily; Imshaug, Melina; Tabrizi, Maryam

    2015-06-01

    The structure-process-outcome quality framework espoused by Donabedian provides a conceptual way to examine and prioritize behavioral health quality measures used by states. This report presents an environmental scan of the quality measures and satisfaction surveys that state Medicaid managed care and behavioral health agencies used prior to Medicaid expansion in 2014. Data were collected by reviewing online documents related to Medicaid managed care contracts for behavioral health, quality strategies, quality improvement plans, quality and performance indicators data, annual outcomes reports, performance measure specification manuals, legislative reports, and Medicaid waiver requests for proposals. Information was publicly available for 29 states. Most states relied on process measures, along with some structure and outcome measures. Although all states reported on at least one process measure of behavioral health quality, 52% of states did not use any outcomes measures and 48% of states had no structure measures. A majority of the states (69%) used behavioral health measures from the National Committee for Quality Assurance's Healthcare Effectiveness Data and Information Set, and all but one state in the sample (97%) used consumer experience-of-care surveys. Many states supplemented these data with locally developed behavioral health indicators that rely on administrative and nonadministrative data. State Medicaid agencies are using nationally recognized as well as local measures to assess quality of behavioral health care. Findings indicate a need for additional nationally endorsed measures in the area of substance use disorders and treatment outcomes.

  17. Utility of the theory of planned behavior to predict nursing staff blood pressure monitoring behaviours.

    PubMed

    Nelson, Joan M; Cook, Paul F; Ingram, Jennifer C

    2014-02-01

    To evaluate constructs from the theory of planned behavior (TPB, Ajzen 2002) - attitudes, sense of control, subjective norms and intentions - as predictors of accuracy in blood pressure monitoring. Despite numerous initiatives aimed at teaching blood pressure measurement techniques, many healthcare providers measure blood pressures incorrectly. Descriptive, cohort design. Medical assistants and licensed practical nurses were asked to complete a questionnaire on TPB variables. These nursing staff's patients had their blood pressures measured and completed a survey about techniques used to measure their blood pressure. We correlated nursing staff's responses on the TBP questionnaire with their intention to measure an accurate blood pressure and with the difference between their actual blood pressure measurement and a second measurement taken by a researcher immediately after the clinic visit. Patients' perceptions of MAs' and LPNs' blood pressure measurement techniques were examined descriptively. Perceived control and social norm predicted intention to measure an accurate blood pressure, with a negative relationship between knowledge and intention. Consistent with the TPB, intention was the only significant predictor of blood pressure measurement accuracy. Theory of planned behavior constructs predicted the healthcare providers' intention to measure blood pressure accurately and intention predicted the actual accuracy of systolic blood pressure measurement. However, participants' knowledge about blood pressure measurement had an unexpected negative relationship with their intentions. These findings have important implications for nursing education departments and organisations which traditionally invest significant time and effort in annual competency training focused on knowledge enhancement by staff. This study suggests that a better strategy might involve efforts to enhance providers' intention to change, particularly by changing social norms or increasing

  18. Neutrons measure phase behavior in pores at Angstrom size

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bardoel, Agatha A; Melnichenko, Yuri B

    Researchers have measured the phase behavior of green house gases in pores at the Angstrom-level, using small angle neutron scattering (SANS) at the Oak Ridge National Laboratory's High Flux Isotope Reactor. Yuri Melnichenko, an instrument scientist on the General Purpose Small Angle Neutron Scattering (GP SANS) Diffractometer at ORNL's High Flux Isotope Reactor, his postdoctoral associate Lilin He and collaborators Nidia Gallego and Cristian Contescu from the Material Sciences Division (ORNL) were engaged in the work. They were studying nanoporous carbons to assess their attractiveness as storage media for hydrogen, with a view to potential use for on-board hydrogen storagemore » for transportation applications. Nanoporous carbons can also serve as electrode material for supercapacitors and batteries. The researchers successfully determined that the most efficiently condensing pore size in a carbon nanoporous material for hydrogen storage is less than one nanometer. In a paper recently published by the Journal of the American Chemical Society, the collaborators used small angle neutron scattering to study how hydrogen condenses in small pores at ambient temperature. They discovered that the surface-molecule interactions create internal pressures in pores that may exceed the external gas pressure by a factor of up to 50. 'This is an exciting result,' Melnichenko said, 'as you achieve extreme densification in pores 'for free', i.e. without spending any energy. These results can be used to guide the development of new carbon adsorbents tailored to maximize hydrogen storage capacities.' Another important factor that defines the adsorption capacity of sub-nanometer pores is their shape. In order to get accurate structural information and maximize sorption capacity, it is important that pores are small and of approximately uniform size. In collaboration with Drexel University's Yury Gogotsi who supplied the samples, Melnichenko and his collaborators used the GP SANS

  19. Measurement of compressed breast thickness by optical stereoscopic photogrammetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyson, Albert H.; Mawdsley, Gordon E.; Yaffe, Martin J.

    2009-02-15

    The determination of volumetric breast density (VBD) from mammograms requires accurate knowledge of the thickness of the compressed breast. In attempting to accurately determine VBD from images obtained on conventional mammography systems, the authors found that the thickness reported by a number of mammography systems in the field varied by as much as 15 mm when compressing the same breast or phantom. In order to evaluate the behavior of mammographic compression systems and to be able to predict the thickness at different locations in the breast on patients, they have developed a method for measuring the local thickness of themore » breast at all points of contact with the compression paddle using optical stereoscopic photogrammetry. On both flat (solid) and compressible phantoms, the measurements were accurate to better than 1 mm with a precision of 0.2 mm. In a pilot study, this method was used to measure thickness on 108 volunteers who were undergoing mammography examination. This measurement tool will allow us to characterize paddle surface deformations, deflections and calibration offsets for mammographic units.« less

  20. Measurement of compressed breast thickness by optical stereoscopic photogrammetry.

    PubMed

    Tyson, Albert H; Mawdsley, Gordon E; Yaffe, Martin J

    2009-02-01

    The determination of volumetric breast density (VBD) from mammograms requires accurate knowledge of the thickness of the compressed breast. In attempting to accurately determine VBD from images obtained on conventional mammography systems, the authors found that the thickness reported by a number of mammography systems in the field varied by as much as 15 mm when compressing the same breast or phantom. In order to evaluate the behavior of mammographic compression systems and to be able to predict the thickness at different locations in the breast on patients, they have developed a method for measuring the local thickness of the breast at all points of contact with the compression paddle using optical stereoscopic photogrammetry. On both flat (solid) and compressible phantoms, the measurements were accurate to better than 1 mm with a precision of 0.2 mm. In a pilot study, this method was used to measure thickness on 108 volunteers who were undergoing mammography examination. This measurement tool will allow us to characterize paddle surface deformations, deflections and calibration offsets for mammographic units.

  1. Amotivation in schizophrenia: integrated assessment with behavioral, clinical, and imaging measures.

    PubMed

    Wolf, Daniel H; Satterthwaite, Theodore D; Kantrowitz, Jacob J; Katchmar, Natalie; Vandekar, Lillie; Elliott, Mark A; Ruparel, Kosha

    2014-11-01

    Motivational deficits play a central role in disability caused by schizophrenia and constitute a major unmet therapeutic need. Negative symptoms have previously been linked to hypofunction in ventral striatum (VS), a core component of brain motivation circuitry. However, it remains unclear to what extent this relationship holds for specific negative symptoms such as amotivation, and this question has not been addressed with integrated behavioral, clinical, and imaging measures. Here, 41 individuals with schizophrenia and 37 controls performed a brief, computerized progressive ratio task (PRT) that quantifies effort exerted in pursuit of monetary reward. Clinical amotivation was assessed using the recently validated Clinical Assessment Interview for Negative Symptoms (CAINS). VS function was probed during functional magnetic resonance imaging using a monetary guessing paradigm. We found that individuals with schizophrenia had diminished motivation as measured by the PRT, which significantly and selectively related to clinical amotivation as measured by the CAINS. Critically, lower PRT motivation in schizophrenia was also dimensionally related to VS hypofunction. Our results demonstrate robust dimensional associations between behavioral amotivation, clinical amotivation, and VS hypofunction in schizophrenia. Integrating behavioral measures such as the PRT will facilitate translational efforts to identify biomarkers of amotivation and to assess response to novel therapeutic interventions. © The Author 2014. Published by Oxford University Press on behalf of the Maryland Psychiatric Research Center. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  2. Measurements of the principal Hugoniots of dense gaseous deuterium-helium mixtures: Combined multi-channel optical pyrometry, velocity interferometry, and streak optical pyrometry measurements

    NASA Astrophysics Data System (ADS)

    Li, Zhi-Guo; Chen, Qi-Feng; Gu, Yun-Jun; Zheng, Jun; Chen, Xiang-Rong

    2016-10-01

    The accurate hydrodynamic description of an event or system that addresses the equations of state, phase transitions, dissociations, ionizations, and compressions, determines how materials respond to a wide range of physical environments. To understand dense matter behavior in extreme conditions requires the continual development of diagnostic methods for accurate measurements of the physical parameters. Here, we present a comprehensive diagnostic technique that comprises optical pyrometry, velocity interferometry, and time-resolved spectroscopy. This technique was applied to shock compression experiments of dense gaseous deuterium-helium mixtures driven via a two-stage light gas gun. The advantage of this approach lies in providing measurements of multiple physical parameters in a single experiment, such as light radiation histories, particle velocity profiles, and time-resolved spectra, which enables simultaneous measurements of shock velocity, particle velocity, pressure, density, and temperature and expands understanding of dense high pressure shock situations. The combination of multiple diagnostics also allows different experimental observables to be measured and cross-checked. Additionally, it implements an accurate measurement of the principal Hugoniots of deuterium-helium mixtures, which provides a benchmark for the impedance matching measurement technique.

  3. An easy way to measure accurately the direct magnetoelectric voltage coefficient of thin film devices

    NASA Astrophysics Data System (ADS)

    Poullain, Gilles; More-Chevalier, Joris; Cibert, Christophe; Bouregba, Rachid

    2017-01-01

    TbxDy1-xFe2/Pt/Pb(Zrx, Ti1-x)O3 thin films were grown on Pt/TiO2/SiO2/Si substrate by multi-target sputtering. The magnetoelectric voltage coefficient αΗΜΕ was determined at room temperature using a lock-in amplifier. By adding, in series in the circuit, a capacitor of the same value as that of the device under test, we were able to demonstrate that the magnetoelectric device behaves as a voltage source. Furthermore, a simple way to subtract the stray voltage arising from the flow of eddy currents in the measurement set-up, is proposed. This allows the easy and accurate determination of the true magnetoelectric voltage coefficient. A large αΗΜΕ of 8.3 V/cm. Oe was thus obtained for a Terfenol-D/Pt/PZT thin film device, without DC magnetic field nor mechanical resonance.

  4. Measurement of shot noise in magnetic tunnel junction and its utilization for accurate system calibration

    NASA Astrophysics Data System (ADS)

    Tamaru, S.; Kubota, H.; Yakushiji, K.; Fukushima, A.; Yuasa, S.

    2017-11-01

    This work presents a technique to calibrate the spin torque oscillator (STO) measurement system by utilizing the whiteness of shot noise. The raw shot noise spectrum in a magnetic tunnel junction based STO in the microwave frequency range is obtained by first subtracting the baseline noise, and then excluding the field dependent mag-noise components reflecting the thermally excited spin wave resonances. As the shot noise is guaranteed to be completely white, the total gain of the signal path should be proportional to the shot noise spectrum obtained by the above procedure, which allows for an accurate gain calibration of the system and a quantitative determination of each noise power. The power spectral density of the shot noise as a function of bias voltage obtained by this technique was compared with a theoretical calculation, which showed excellent agreement when the Fano factor was assumed to be 0.99.

  5. Physical activity measurements affected participants' behavior in a randomized controlled trial.

    PubMed

    van Sluijs, Esther M F; van Poppel, Mireille N M; Twisk, Jos W R; van Mechelen, Willem

    2006-04-01

    Assessing levels and determinants of physical activity as outcome measurements might have an independent effect on participant's physical activity behavior. The objective is to study this effect in a randomized controlled trial (RCT) promoting regular physical activity in Dutch general practice. Using a Solomon four-group design, participants were randomized twice. After randomization to a control or intervention-condition at general practice level (N = 29), participants were randomized to a group participating in measurements at baseline, 2 and 6 months (3M-group, N = 361), or a group only participating in measurements at 6 months (1M-group, N = 356). Outcome measures assessed at 6 months included: level of physical activity (self-reported and objectively measured with accelerometry), meeting ACSM/CDC guideline for regular physical activity, stage of change, and determinants of physical activity. Follow-up data on 635 participants (89%) was collected. Statistically significant measurement effects were found for meeting the ACSM/CDC guideline (self-reported), self-efficacy for resisting relapse, knowledge, and on awareness. Other outcome measures showed positive trends, except stages of change. Measurements of physical activity affect participant's physical activity behavior, possibly triggered by a raised awareness about their own physical activity level. Implications for future research are discussed, as well as methodologic limitations of the study design.

  6. Accurate measurement of chest compression depth using impulse-radio ultra-wideband sensor on a mattress.

    PubMed

    Yu, Byung Gyu; Oh, Je Hyeok; Kim, Yeomyung; Kim, Tae Wook

    2017-01-01

    We developed a new chest compression depth (CCD) measuring technology using radar and impulse-radio ultra-wideband (IR-UWB) sensor. This study was performed to determine its accuracy on a soft surface. Four trials, trial 1: chest compressions on the floor using an accelerometer device; trial 2: chest compressions on the floor using an IR-UWB sensor; trial 3: chest compressions on a foam mattress using an accelerometer device; trial 4: chest compressions on a foam mattress using an IR-UWB sensor, were performed in a random order. In all the trials, a cardiopulmonary resuscitation provider delivered 50 uninterrupted chest compressions to a manikin. The CCD measured by the manikin and the device were as follows: 57.42 ± 2.23 and 53.92 ± 2.92 mm, respectively in trial 1 (p < 0.001); 56.29 ± 1.96 and 54.16 ± 3.90 mm, respectively in trial 2 (p < 0.001); 55.61 ± 1.57 and 103.48 ± 10.48 mm, respectively in trial 3 (p < 0.001); 57.14 ± 3.99 and 55.51 ± 3.39 mm, respectively in trial 4 (p = 0.012). The gaps between the CCD measured by the manikin and the devices (accelerometer device vs. IR-UWB sensor) on the floor were not different (3.50 ± 2.08 mm vs. 3.15 ± 2.27 mm, respectively, p = 0.136). However, the gaps were significantly different on the foam mattress (48.53 ± 5.65 mm vs. 4.10 ± 2.47 mm, p < 0.001). The IR-UWB sensor could measure the CCD accurately both on the floor and on the foam mattress.

  7. Comparison of self-report and objective measures of driving behavior and road safety: A systematic review.

    PubMed

    Kaye, Sherrie-Anne; Lewis, Ioni; Freeman, James

    2018-06-01

    This research systematically reviewed the existing literature in regards to studies which have used both self-report and objective measures of driving behavior. The objective of the current review was to evaluate disparities or similarities between self-report and objective measures of driving behavior. Searches were undertaken in the following electronic databases, PsycINFO, PubMed, and Scopus, for peer-reviewed full-text articles that (1) focused on road safety, and (2) compared both subjective and objective measures of driving performance or driver safety. A total of 22,728 articles were identified, with 19 articles, comprising 20 studies, included as part of the review. The research reported herein suggested that for some behaviors (e.g., driving in stressful situations) there were similarities between self-report and objective measures while for other behaviors (e.g., sleepiness and vigilance states) there were differences between these measurement techniques. In addition, findings from some studies suggested that in-vehicle devices may be a valid measurement tool to assess driving exposure in older drivers. Further research is needed to examine the correspondence between self-report and objective measures of driving behavior. In particular, there is a need to increase the number of studies which compare "like with like" as it is difficult to draw comparisons when there are variations in measurement tools used. Incorporating a range of objective and self-report measurements tools in research would help to ensure that the methods used offer the most reliable measures of assessing on-road behaviors. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  8. Laboratory Measured Behavioral Impulsivity Relates to Suicide Attempt History

    ERIC Educational Resources Information Center

    Dougherty, Donald M.; Mathias, Charles W.; Marsh, Dawn M.; Papageorgiou, T. Dorina; Swann, Alan C.; Moeller, F. Gerard

    2004-01-01

    The purpose of this study was to examine the relationship between laboratory behavioral measured impulsivity (using the Immediate and Delayed Memory Tasks) and suicidal attempt histories. Three groups of adults were recruited, those with either: no previous suicide attempts (Control, n = 20), only a single suicide attempt (Single, n = 20), or…

  9. Measuring and Visualizing Students' Behavioral Engagement in Writing Activities

    ERIC Educational Resources Information Center

    Liu, Ming; Calvo, Rafael A.; Pardo, Abelardo; Martin, Andrew

    2015-01-01

    Engagement is critical to the success of learning activities such as writing, and can be promoted with appropriate feedback. Current engagement measures rely mostly on data collected by observers or self-reported by the participants. In this paper, we describe a learning analytic system called Tracer, which derives behavioral engagement measures…

  10. Concentration and limit behaviors of stationary measures

    NASA Astrophysics Data System (ADS)

    Huang, Wen; Ji, Min; Liu, Zhenxin; Yi, Yingfei

    2018-04-01

    In this paper, we study limit behaviors of stationary measures of the Fokker-Planck equations associated with a system of ordinary differential equations perturbed by a class of multiplicative noise including additive white noise case. As the noises are vanishing, various results on the invariance and concentration of the limit measures are obtained. In particular, we show that if the noise perturbed systems admit a uniform Lyapunov function, then the stationary measures form a relatively sequentially compact set whose weak∗-limits are invariant measures of the unperturbed system concentrated on its global attractor. In the case that the global attractor contains a strong local attractor, we further show that there exists a family of admissible multiplicative noises with respect to which all limit measures are actually concentrated on the local attractor; and on the contrary, in the presence of a strong local repeller in the global attractor, there exists a family of admissible multiplicative noises with respect to which no limit measure can be concentrated on the local repeller. Moreover, we show that if there is a strongly repelling equilibrium in the global attractor, then limit measures with respect to typical families of multiplicative noises are always concentrated away from the equilibrium. As applications of these results, an example of stochastic Hopf bifurcation and an example with non-decomposable ω-limit sets are provided. Our study is closely related to the problem of noise stability of compact invariant sets and invariant measures of the unperturbed system.

  11. Development of an Attachment-Informed Measure of Sexual Behavior in Late Adolescence

    ERIC Educational Resources Information Center

    Szielasko, Alicia L.; Symons, Douglas K.; Price, E. Lisa

    2013-01-01

    There is considerable interest in relations between sexual behavior and romantic attachment styles in adolescence as attachment needs are increasingly met through intimate partners rather than parents. The objectives of this research were to organize a measure of sexual behavior within an attachment theory framework, and then show that this new…

  12. Children's Assertive Behavior: The Reliability and Validity of Three Self-Report Measures.

    ERIC Educational Resources Information Center

    Scanlon, Elizabeth M.; Ollendick, Thomas H.

    1985-01-01

    The internal consistency and validity of three new scales for measuring assertiveness in children were tested. Two of the scales were able to "unbind" aggressive from assertive behavior, while the third was able to "unbind" submissive from assertive behavior. At present, a combination of the three scales is recommended. (KH)

  13. MELIFT - A new device for accurate measurements in a snow rich environment

    NASA Astrophysics Data System (ADS)

    Dorninger, M.

    2012-04-01

    A deep snow pack, remote locations, no external power supply and very low temperatures are often the main ingredients when it comes to the deployment of meteorological stations in mountainous terrain. The accurate position of the sensor related to the snow surface is normally not known. A new device called METLIFT overcomes the problems. WMO recommends a height between 1.2 m and 2 m above ground level for the measurement of air temperature and humidity. The height above ground level is specified to take care of the possible strong vertical temperature and humidity gradients at the lowest layers in the atmosphere. Especially in snow rich and remote locations it may be hardly possible to follow this advice. Therefore most of the meteorological stations in mountainous terrain are situated at mountain tops where strong winds will blow off the snow or in valleys where a daily inspection of the sensors is possible. In other unpopulated mountainous areas, e.g. basins, plateaus, the distance of the sensor to the snow surface is not known or the sensor will be snow-covered. A new device was developed to guarantee the sensor height above surface within the WMO limits in harsh and remote environments. An ultrasonic snow height sensor measures the distance to the snow surface. If it exceeds certain limits due to snow accumulation or snow melt the lift adapts its height accordingly. The prototype of METLIFT has been installed in Lower Austria at an altitude of 1000m. The lift is 6 m high and can pull out for another 4 m. Sensor arms are mounted every meter to allow the connection of additional sensors or to measure a profile of a certain parameter of the lowest 5 m above surface. Sensors can be added easily since cable wiring is provided to each sensor arm. Horizontal winds are measured at 7 m height above surface. METLIFT is independent of external power supply. Three lead gel accumulators recharged by three solar panels provide the energy necessary for the sensors, the data

  14. Objective Physiological Measurements but Not Subjective Reports Moderate the Effect of Hunger on Choice Behavior

    PubMed Central

    Shabat-Simon, Maytal; Shuster, Anastasia; Sela, Tal; Levy, Dino J.

    2018-01-01

    Hunger is a powerful driver of human behavior, and is therefore of great interest to the study of psychology, economics, and consumer behavior. Assessing hunger levels in experiments is often biased, when using self-report methods, or complex, when using blood tests. We propose a novel way of objectively measuring subjects’ levels of hunger by identifying levels of alpha-amylase (AA) enzyme in their saliva samples. We used this measure to uncover the effect of hunger on different types of choice behaviors. We found that hunger increases risk-seeking behavior in a lottery-choice task, modifies levels of vindictiveness in a social decision-making task, but does not have a detectible effect on economic inconsistency in a budget-set choice task. Importantly, these findings were moderated by AA levels and not by self-report measures. We demonstrate the effects hunger has on choice behavior and the problematic nature of subjective measures of physiological states, and propose to use reliable and valid biologically based methods to overcome these problems. PMID:29875715

  15. Accurate measurement of transgene copy number in crop plants using droplet digital PCR.

    PubMed

    Collier, Ray; Dasgupta, Kasturi; Xing, Yan-Ping; Hernandez, Bryan Tarape; Shao, Min; Rohozinski, Dominica; Kovak, Emma; Lin, Jeanie; de Oliveira, Maria Luiza P; Stover, Ed; McCue, Kent F; Harmon, Frank G; Blechl, Ann; Thomson, James G; Thilmony, Roger

    2017-06-01

    Genetic transformation is a powerful means for the improvement of crop plants, but requires labor- and resource-intensive methods. An efficient method for identifying single-copy transgene insertion events from a population of independent transgenic lines is desirable. Currently, transgene copy number is estimated by either Southern blot hybridization analyses or quantitative polymerase chain reaction (qPCR) experiments. Southern hybridization is a convincing and reliable method, but it also is expensive, time-consuming and often requires a large amount of genomic DNA and radioactively labeled probes. Alternatively, qPCR requires less DNA and is potentially simpler to perform, but its results can lack the accuracy and precision needed to confidently distinguish between one- and two-copy events in transgenic plants with large genomes. To address this need, we developed a droplet digital PCR-based method for transgene copy number measurement in an array of crops: rice, citrus, potato, maize, tomato and wheat. The method utilizes specific primers to amplify target transgenes, and endogenous reference genes in a single duplexed reaction containing thousands of droplets. Endpoint amplicon production in the droplets is detected and quantified using sequence-specific fluorescently labeled probes. The results demonstrate that this approach can generate confident copy number measurements in independent transgenic lines in these crop species. This method and the compendium of probes and primers will be a useful resource for the plant research community, enabling the simple and accurate determination of transgene copy number in these six important crop species. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  16. The modified hole board--measuring behavior, cognition and social interaction in mice and rats.

    PubMed

    Labots, Maaike; Van Lith, Hein A; Ohl, Frauke; Arndt, Saskia S

    2015-04-08

    This protocol describes the modified hole board (mHB), which combines features from a traditional hole board and open field and is designed to measure multiple dimensions of unconditioned behavior in small laboratory mammals (e.g., mice, rats, tree shrews and small primates). This paradigm is a valuable alternative for the use of a behavioral test battery, since a broad behavioral spectrum of an animal's behavioral profile can be investigated in one single test. The apparatus consists of a box, representing the 'protected' area, separated from a group compartment. A board, on which small cylinders are staggered in three lines, is placed in the center of the box, representing the 'unprotected' area of the set-up. The cognitive abilities of the animals can be measured by baiting some cylinders on the board and measuring the working and reference memory. Other unconditioned behavior, such as activity-related-, anxiety-related- and social behavior, can be observed using this paradigm. Behavioral flexibility and the ability to habituate to a novel environment can additionally be observed by subjecting the animals to multiple trials in the mHB, revealing insight into the animals' adaptive capacities. Due to testing order effects in a behavioral test battery, naïve animals should be used for each individual experiment. By testing multiple behavioral dimensions in a single paradigm and thereby circumventing this issue, the number of experimental animals used is reduced. Furthermore, by avoiding social isolation during testing and without the need to food deprive the animals, the mHB represents a behavioral test system, inducing if any, very low amount of stress.

  17. The need for accurate long-term measurements of water vapor in the upper troposphere and lower stratosphere with global coverage.

    PubMed

    Müller, Rolf; Kunz, Anne; Hurst, Dale F; Rolf, Christian; Krämer, Martina; Riese, Martin

    2016-02-01

    Water vapor is the most important greenhouse gas in the atmosphere although changes in carbon dioxide constitute the "control knob" for surface temperatures. While the latter fact is well recognized, resulting in extensive space-borne and ground-based measurement programs for carbon dioxide as detailed in the studies by Keeling et al. (1996), Kuze et al. (2009), and Liu et al. (2014), the need for an accurate characterization of the long-term changes in upper tropospheric and lower stratospheric (UTLS) water vapor has not yet resulted in sufficiently extensive long-term international measurement programs (although first steps have been taken). Here, we argue for the implementation of a long-term balloon-borne measurement program for UTLS water vapor covering the entire globe that will likely have to be sustained for hundreds of years.

  18. A near-optimal low complexity sensor fusion technique for accurate indoor localization based on ultrasound time of arrival measurements from low-quality sensors

    NASA Astrophysics Data System (ADS)

    Mitilineos, Stelios A.; Argyreas, Nick D.; Thomopoulos, Stelios C. A.

    2009-05-01

    A fusion-based localization technique for location-based services in indoor environments is introduced herein, based on ultrasound time-of-arrival measurements from multiple off-the-shelf range estimating sensors which are used in a market-available localization system. In-situ field measurements results indicated that the respective off-the-shelf system was unable to estimate position in most of the cases, while the underlying sensors are of low-quality and yield highly inaccurate range and position estimates. An extensive analysis is performed and a model of the sensor-performance characteristics is established. A low-complexity but accurate sensor fusion and localization technique is then developed, which consists inof evaluating multiple sensor measurements and selecting the one that is considered most-accurate based on the underlying sensor model. Optimality, in the sense of a genie selecting the optimum sensor, is subsequently evaluated and compared to the proposed technique. The experimental results indicate that the proposed fusion method exhibits near-optimal performance and, albeit being theoretically suboptimal, it largely overcomes most flaws of the underlying single-sensor system resulting in a localization system of increased accuracy, robustness and availability.

  19. Is digital photography an accurate and precise method for measuring range of motion of the hip and knee?

    PubMed

    Russo, Russell R; Burn, Matthew B; Ismaily, Sabir K; Gerrie, Brayden J; Han, Shuyang; Alexander, Jerry; Lenherr, Christopher; Noble, Philip C; Harris, Joshua D; McCulloch, Patrick C

    2017-09-07

    Accurate measurements of knee and hip motion are required for management of musculoskeletal pathology. The purpose of this investigation was to compare three techniques for measuring motion at the hip and knee. The authors hypothesized that digital photography would be equivalent in accuracy and show higher precision compared to the other two techniques. Using infrared motion capture analysis as the reference standard, hip flexion/abduction/internal rotation/external rotation and knee flexion/extension were measured using visual estimation, goniometry, and photography on 10 fresh frozen cadavers. These measurements were performed by three physical therapists and three orthopaedic surgeons. Accuracy was defined by the difference from the reference standard, while precision was defined by the proportion of measurements within either 5° or 10°. Analysis of variance (ANOVA), t-tests, and chi-squared tests were used. Although two statistically significant differences were found in measurement accuracy between the three techniques, neither of these differences met clinical significance (difference of 1.4° for hip abduction and 1.7° for the knee extension). Precision of measurements was significantly higher for digital photography than: (i) visual estimation for hip abduction and knee extension, and (ii) goniometry for knee extension only. There was no clinically significant difference in measurement accuracy between the three techniques for hip and knee motion. Digital photography only showed higher precision for two joint motions (hip abduction and knee extension). Overall digital photography shows equivalent accuracy and near-equivalent precision to visual estimation and goniometry.

  20. Musical aptitude and second language pronunciation skills in school-aged children: neural and behavioral evidence.

    PubMed

    Milovanov, Riia; Huotilainen, Minna; Välimäki, Vesa; Esquef, Paulo A A; Tervaniemi, Mari

    2008-02-15

    The main focus of this study was to examine the relationship between musical aptitude and second language pronunciation skills. We investigated whether children with superior performance in foreign language production represent musical sound features more readily in the preattentive level of neural processing compared with children with less-advanced production skills. Sound processing accuracy was examined in elementary school children by means of event-related potential (ERP) recordings and behavioral measures. Children with good linguistic skills had better musical skills as measured by the Seashore musicality test than children with less accurate linguistic skills. The ERP data accompany the results of the behavioral tests: children with good linguistic skills showed more pronounced sound-change evoked activation with the music stimuli than children with less accurate linguistic skills. Taken together, the results imply that musical and linguistic skills could partly be based on shared neural mechanisms.

  1. A Cost-Effective Transparency-Based Digital Imaging for Efficient and Accurate Wound Area Measurement

    PubMed Central

    Li, Pei-Nan; Li, Hong; Wu, Mo-Li; Wang, Shou-Yu; Kong, Qing-You; Zhang, Zhen; Sun, Yuan; Liu, Jia; Lv, De-Cheng

    2012-01-01

    Wound measurement is an objective and direct way to trace the course of wound healing and to evaluate therapeutic efficacy. Nevertheless, the accuracy and efficiency of the current measurement methods need to be improved. Taking the advantages of reliability of transparency tracing and the accuracy of computer-aided digital imaging, a transparency-based digital imaging approach is established, by which data from 340 wound tracing were collected from 6 experimental groups (8 rats/group) at 8 experimental time points (Day 1, 3, 5, 7, 10, 12, 14 and 16) and orderly archived onto a transparency model sheet. This sheet was scanned and its image was saved in JPG form. Since a set of standard area units from 1 mm2 to 1 cm2 was integrated into the sheet, the tracing areas in JPG image were measured directly, using the “Magnetic lasso tool” in Adobe Photoshop program. The pixel values/PVs of individual outlined regions were obtained and recorded in an average speed of 27 second/region. All PV data were saved in an excel form and their corresponding areas were calculated simultaneously by the formula of Y (PV of the outlined region)/X (PV of standard area unit) × Z (area of standard unit). It took a researcher less than 3 hours to finish area calculation of 340 regions. In contrast, over 3 hours were expended by three skillful researchers to accomplish the above work with traditional transparency-based method. Moreover, unlike the results obtained traditionally, little variation was found among the data calculated by different persons and the standard area units in different sizes and shapes. Given its accurate, reproductive and efficient properties, this transparency-based digital imaging approach would be of significant values in basic wound healing research and clinical practice. PMID:22666449

  2. The "drinking-buddy" scale as a measure of para-social behavior.

    PubMed

    Powell, Larry; Richmond, Virginia P; Cantrell-Williams, Glenda

    2012-06-01

    Para-social behavior is a form of quasi-interpersonal behavior that results when audience members develop bonds with media personalities that can resemble interpersonal social interaction, but is not usually applied to political communication. This study tested whether the "Drinking-Buddy" Scale, a simple question frequently used in political communication, could be interpreted as a single-item measure of para-social behavior with respect to political candidates in terms of image judgments related to interpersonal attraction and perceived similarity to self. The participants were college students who had voted in the 2008 election. They rated the candidates, Obama or McCain, as drinking buddies and then rated the candidates' perceived similarity to themselves in attitude and background, and also the social and task attraction to the candidate. If the drinking-buddy rating serves as a proxy measure for para-social behavior, then it was expected that participants' ratings for all four kinds of similarity to and attraction toward a candidate would be higher for the candidate they chose as a drinking buddy. The directional hypotheses were supported for interpersonal attraction, but not for perceived similarity. These results indicate that the drinking-buddy scale predicts ratings of interpersonal attraction, while voters may view perceived similarity as an important but not essential factor in their candidate preference.

  3. Indirect viscosimetric method is less accurate than ektacytometry for the measurement of red blood cell deformability.

    PubMed

    Vent-Schmidt, Jens; Waltz, Xavier; Pichon, Aurélien; Hardy-Dessources, Marie-Dominique; Romana, Marc; Connes, Philippe

    2015-01-01

    The aim of this study was to test the accuracy of viscosimetric method to estimate the red blood cell (RBC) deformability properties. Thirty-three subjects were enrolled in this study: 6 healthy subjects (AA), 11 patients with sickle cell-hemoglobin C disease (SC) and 16 patients with sickle cell anemia (SS). Two methods were used to assess RBC deformability: 1) indirect viscosimetric method and 2) ektacytometry. The indirect viscosimetric method was based on the Dintenfass equation where blood viscosity, plasma viscosity and hematocrit are measured and used to calculate an index of RBC rigidity (Tk index). The RBC deformability/rigidity of the three groups was compared using the two methods. Tk index was not different between SS and SC patients and the two groups had higher values than AA group. When ektacytometry was used, RBC deformability was lower in SS and SC groups compared to the AA group and SS and SC patients were different. Although the two measures of RBC deformability were correlated, the association was not very high. Bland and Altman analysis demonstrated a 3.25 bias suggesting a slight difference between the two methods. In addition, the limit of agreement represented 28% (>15%) of the mean values of RBC deformability, showing no interchangeability between the two methods. In conclusion, measuring RBC deformability by indirect viscosimetry is less accurate than by ektacytometry, which is considered the gold standard.

  4. Behavioral Measures of Auditory Streaming in Ferrets (Mustela putorius)

    PubMed Central

    Ma, Ling; Yin, Pingbo; Micheyl, Christophe; Oxenham, Andrew J.; Shamma, Shihab A.

    2015-01-01

    An important aspect of the analysis of auditory “scenes” relates to the perceptual organization of sound sequences into auditory “streams.” In this study, we adapted two auditory perception tasks, used in recent human psychophysical studies, to obtain behavioral measures of auditory streaming in ferrets (Mustela putorius). One task involved the detection of shifts in the frequency of tones within an alternating tone sequence. The other task involved the detection of a stream of regularly repeating target tones embedded within a randomly varying multitone background. In both tasks, performance was measured as a function of various stimulus parameters, which previous psychophysical studies in humans have shown to influence auditory streaming. Ferret performance in the two tasks was found to vary as a function of these parameters in a way that is qualitatively consistent with the human data. These results suggest that auditory streaming occurs in ferrets, and that the two tasks described here may provide a valuable tool in future behavioral and neurophysiological studies of the phenomenon. PMID:20695663

  5. Measuring Accurately Single-Phase Sinusoidal and Non-Sinusoidal Power.

    DTIC Science & Technology

    1983-01-01

    current component. Since the induction watthour meter is designed for measuring ac variations only, the creation of a dc component in an ac circuit due...available and the basic principle of measurement used in each. 3.1 Power Measuring Meters Instruments designed to measure the amount of average power...1.0 percent of full scale and + 0.5% of reading. 3.2 Encrgy Measuring Meters Instruments designed to measure the amount of power consumed in a circuit

  6. Psychometric evaluation of a multi-dimensional measure of satisfaction with behavioral interventions.

    PubMed

    Sidani, Souraya; Epstein, Dana R; Fox, Mary

    2017-10-01

    Treatment satisfaction is recognized as an essential aspect in the evaluation of an intervention's effectiveness, but there is no measure that provides for its comprehensive assessment with regard to behavioral interventions. Informed by a conceptualization generated from a literature review, we developed a measure that covers several domains of satisfaction with behavioral interventions. In this paper, we briefly review its conceptualization and describe the Multi-Dimensional Treatment Satisfaction Measure (MDTSM) subscales. Satisfaction refers to the appraisal of the treatment's process and outcome attributes. The MDTSM has 11 subscales assessing treatment process and outcome attributes: treatment components' suitability and utility, attitude toward treatment, desire for continued treatment use, therapist competence and interpersonal style, format and dose, perceived benefits of the health problem and everyday functioning, discomfort, and attribution of outcomes to treatment. The MDTSM was completed by persons (N = 213) in the intervention group in a large trial of a multi-component behavioral intervention for insomnia within 1 week following treatment completion. The MDTSM's subscales demonstrated internal consistency reliability (α: .65 - .93) and validity (correlated with self-reported adherence and perceived insomnia severity at post-test). The MDTSM subscales can be used to assess satisfaction with behavioral interventions and point to aspects of treatments that are viewed favorably or unfavorably. © 2017 Wiley Periodicals, Inc.

  7. Use of electric field sensors for recording respiration, heart rate, and stereotyped motor behaviors in the rodent home cage.

    PubMed

    Noble, Donald J; MacDowell, Camden J; McKinnon, Michael L; Neblett, Tamra I; Goolsby, William N; Hochman, Shawn

    2017-02-01

    Numerous environmental and genetic factors can contribute significantly to behavioral and cardiorespiratory variability observed experimentally. Affordable technologies that allow for noninvasive home cage capture of physio-behavioral variables should enhance understanding of inter-animal variability including after experimental interventions. We assessed whether EPIC electric field sensors (Plessey Semiconductors) embedded within or attached externally to a rodent's home cage could accurately record respiration, heart rate, and motor behaviors. Current systems for quantification of behavioral variables require expensive specialty equipment, while measures of respiratory and heart rate are often provided by surgically implanted or chronically affixed devices. Sensors accurately encoded imposed sinusoidal changes in electric field tested at frequencies ranging from 0.5-100Hz. Mini-metronome arm movements were easily detected, but response magnitude was highly distance dependent. Sensors accurately reported respiration during whole-body plethysmography. In anesthetized rodents, PVC tube-embedded sensors provided accurate mechanical detection of both respiratory and heart rate. Comparable success was seen in naturally behaving animals at rest or sleeping when sensors were attached externally. Video-verified motor behaviors (sniffing, grooming, chewing, and rearing) were detectable and largely separable by their characteristic voltage fluctuations. Larger movement-related events had comparably larger voltage dynamics that easily allowed for a broad approximation of overall motor activity. Spectrograms were used to quickly depict characteristic frequencies in long-lasting recordings, while filtering and thresholding software allowed for detection and quantification of movement-related physio-behavioral events. EPIC electric field sensors provide a means for affordable non-contact home cage detection of physio-behavioral variables. Copyright © 2016 Elsevier B.V. All

  8. Computerized tomography magnified bone windows are superior to standard soft tissue windows for accurate measurement of stone size: an in vitro and clinical study.

    PubMed

    Eisner, Brian H; Kambadakone, Avinash; Monga, Manoj; Anderson, James K; Thoreson, Andrew A; Lee, Hang; Dretler, Stephen P; Sahani, Dushyant V

    2009-04-01

    We determined the most accurate method of measuring urinary stones on computerized tomography. For the in vitro portion of the study 24 calculi, including 12 calcium oxalate monohydrate and 12 uric acid stones, that had been previously collected at our clinic were measured manually with hand calipers as the gold standard measurement. The calculi were then embedded into human kidney-sized potatoes and scanned using 64-slice multidetector computerized tomography. Computerized tomography measurements were performed at 4 window settings, including standard soft tissue windows (window width-320 and window length-50), standard bone windows (window width-1120 and window length-300), 5.13x magnified soft tissue windows and 5.13x magnified bone windows. Maximum stone dimensions were recorded. For the in vivo portion of the study 41 patients with distal ureteral stones who underwent noncontrast computerized tomography and subsequently spontaneously passed the stones were analyzed. All analyzed stones were 100% calcium oxalate monohydrate or mixed, calcium based stones. Stones were prospectively collected at the clinic and the largest diameter was measured with digital calipers as the gold standard. This was compared to computerized tomography measurements using 4.0x magnified soft tissue windows and 4.0x magnified bone windows. Statistical comparisons were performed using Pearson's correlation and paired t test. In the in vitro portion of the study the most accurate measurements were obtained using 5.13x magnified bone windows with a mean 0.13 mm difference from caliper measurement (p = 0.6). Measurements performed in the soft tissue window with and without magnification, and in the bone window without magnification were significantly different from hand caliper measurements (mean difference 1.2, 1.9 and 1.4 mm, p = 0.003, <0.001 and 0.0002, respectively). When comparing measurement errors between stones of different composition in vitro, the error for calcium oxalate

  9. High-accurate optical fiber liquid level sensor

    NASA Astrophysics Data System (ADS)

    Sun, Dexing; Chen, Shouliu; Pan, Chao; Jin, Henghuan

    1991-08-01

    A highly accurate optical fiber liquid level sensor is presented. The single-chip microcomputer is used to process and control the signal. This kind of sensor is characterized by self-security and is explosion-proof, so it can be applied in any liquid level detecting areas, especially in the oil and chemical industries. The theories and experiments about how to improve the measurement accuracy are described. The relative error for detecting the measurement range 10 m is up to 0.01%.

  10. Accurate measurement of chest compression depth using impulse-radio ultra-wideband sensor on a mattress

    PubMed Central

    Kim, Yeomyung

    2017-01-01

    Objective We developed a new chest compression depth (CCD) measuring technology using radar and impulse-radio ultra-wideband (IR-UWB) sensor. This study was performed to determine its accuracy on a soft surface. Methods Four trials, trial 1: chest compressions on the floor using an accelerometer device; trial 2: chest compressions on the floor using an IR-UWB sensor; trial 3: chest compressions on a foam mattress using an accelerometer device; trial 4: chest compressions on a foam mattress using an IR-UWB sensor, were performed in a random order. In all the trials, a cardiopulmonary resuscitation provider delivered 50 uninterrupted chest compressions to a manikin. Results The CCD measured by the manikin and the device were as follows: 57.42 ± 2.23 and 53.92 ± 2.92 mm, respectively in trial 1 (p < 0.001); 56.29 ± 1.96 and 54.16 ± 3.90 mm, respectively in trial 2 (p < 0.001); 55.61 ± 1.57 and 103.48 ± 10.48 mm, respectively in trial 3 (p < 0.001); 57.14 ± 3.99 and 55.51 ± 3.39 mm, respectively in trial 4 (p = 0.012). The gaps between the CCD measured by the manikin and the devices (accelerometer device vs. IR-UWB sensor) on the floor were not different (3.50 ± 2.08 mm vs. 3.15 ± 2.27 mm, respectively, p = 0.136). However, the gaps were significantly different on the foam mattress (48.53 ± 5.65 mm vs. 4.10 ± 2.47 mm, p < 0.001). Conclusion The IR-UWB sensor could measure the CCD accurately both on the floor and on the foam mattress. PMID:28854262

  11. Only Behavioral But Not Self-Report Measures of Speech Perception Correlate with Cognitive Abilities.

    PubMed

    Heinrich, Antje; Henshaw, Helen; Ferguson, Melanie A

    2016-01-01

    Good speech perception and communication skills in everyday life are crucial for participation and well-being, and are therefore an overarching aim of auditory rehabilitation. Both behavioral and self-report measures can be used to assess these skills. However, correlations between behavioral and self-report speech perception measures are often low. One possible explanation is that there is a mismatch between the specific situations used in the assessment of these skills in each method, and a more careful matching across situations might improve consistency of results. The role that cognition plays in specific speech situations may also be important for understanding communication, as speech perception tests vary in their cognitive demands. In this study, the role of executive function, working memory (WM) and attention in behavioral and self-report measures of speech perception was investigated. Thirty existing hearing aid users with mild-to-moderate hearing loss aged between 50 and 74 years completed a behavioral test battery with speech perception tests ranging from phoneme discrimination in modulated noise (easy) to words in multi-talker babble (medium) and keyword perception in a carrier sentence against a distractor voice (difficult). In addition, a self-report measure of aided communication, residual disability from the Glasgow Hearing Aid Benefit Profile, was obtained. Correlations between speech perception tests and self-report measures were higher when specific speech situations across both were matched. Cognition correlated with behavioral speech perception test results but not with self-report. Only the most difficult speech perception test, keyword perception in a carrier sentence with a competing distractor voice, engaged executive functions in addition to WM. In conclusion, any relationship between behavioral and self-report speech perception is not mediated by a shared correlation with cognition.

  12. Only Behavioral But Not Self-Report Measures of Speech Perception Correlate with Cognitive Abilities

    PubMed Central

    Heinrich, Antje; Henshaw, Helen; Ferguson, Melanie A.

    2016-01-01

    Good speech perception and communication skills in everyday life are crucial for participation and well-being, and are therefore an overarching aim of auditory rehabilitation. Both behavioral and self-report measures can be used to assess these skills. However, correlations between behavioral and self-report speech perception measures are often low. One possible explanation is that there is a mismatch between the specific situations used in the assessment of these skills in each method, and a more careful matching across situations might improve consistency of results. The role that cognition plays in specific speech situations may also be important for understanding communication, as speech perception tests vary in their cognitive demands. In this study, the role of executive function, working memory (WM) and attention in behavioral and self-report measures of speech perception was investigated. Thirty existing hearing aid users with mild-to-moderate hearing loss aged between 50 and 74 years completed a behavioral test battery with speech perception tests ranging from phoneme discrimination in modulated noise (easy) to words in multi-talker babble (medium) and keyword perception in a carrier sentence against a distractor voice (difficult). In addition, a self-report measure of aided communication, residual disability from the Glasgow Hearing Aid Benefit Profile, was obtained. Correlations between speech perception tests and self-report measures were higher when specific speech situations across both were matched. Cognition correlated with behavioral speech perception test results but not with self-report. Only the most difficult speech perception test, keyword perception in a carrier sentence with a competing distractor voice, engaged executive functions in addition to WM. In conclusion, any relationship between behavioral and self-report speech perception is not mediated by a shared correlation with cognition. PMID:27242564

  13. School-based behavioral assessment tools are reliable and valid for measurement of fruit and vegetable intake, physical activity, and television viewing in young children.

    PubMed

    Economos, Christina D; Sacheck, Jennifer M; Kwan Ho Chui, Kenneth; Irizarry, Laura; Irizzary, Laura; Guillemont, Juliette; Collins, Jessica J; Hyatt, Raymond R

    2008-04-01

    Interventions aiming to modify the dietary and physical activity behaviors of young children require precise and accurate measurement tools. As part of a larger community-based project, three school-based questionnaires were developed to assess (a) fruit and vegetable intake, (b) physical activity and television (TV) viewing, and (c) perceived parental support for diet and physical activity. Test-retest reliability was performed on all questionnaires and validity was measured for fruit and vegetable intake, physical activity, and TV viewing. Eighty-four school children (8.3+/-1.1 years) were studied. Test-retest reliability was performed by administering questionnaires twice, 1 to 2 hours apart. Validity of the fruit and vegetable questionnaire was measured by direct observation, while the physical activity and TV questionnaire was validated by a parent phone interview. All three questionnaires yielded excellent test-retest reliability (P<0.001). The majority of fruit and vegetable questions and the questions regarding specific physical activities and TV viewing were valid. Low validity scores were found for questions on watching TV during breakfast or dinner. These questionnaires are reliable and valid tools to assess fruit and vegetable intake, physical activity, and TV viewing behaviors in early elementary school-aged children. Methods for assessment of children's TV viewing during meals should be further investigated because of parent-child discrepancies.

  14. Factors affecting the adoption of home-heating energy-conservation measures: a behavioral approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Macey, S.M.

    1982-01-01

    The basic aim of this research is to better understand homeowners' adoption of home-heating energy-conservation measures by analyzing a number of factors that are thought to be underlying determinants of adoption behavior. The basic approach is behavioral drawing on the knowledge built up in behavioral geography through studies on natural hazards and innovation diffusion, and borrowing from psychological theories of attitude formation and decision making. In particular, six factors (information, environmental personality, socio-economic and demographic factors, dwelling unit characteristics, psychological variables, and past experience) are shown to directly and indirectly affect adoption behavior. By this means, differences between adopters andmore » nonadopters in the underlying cognitive structures and in the situational factors that affect their decisions are identified. The study focuses on the adoption of three measures: reducing winter night-time thermostat settings, changing or cleaning furnace filters, and installing an automatic setback thermostat. Personal interviews with a random sample of 159 homeowners in Decatur, Illinois serve as the main data base. Results indicate that adoption behavior is determined more by past experience, than by intention. Beliefs, attitudes, and social influences affect behavior indirectly through intention. These psychological variables also act as mediators between information, knowledge, environmental personality, situational variables and behavior. In particular, respondent's age, previous home ownership, and length of residence act indirectly on adoption behavior. Each of these reflects the amount of past experience the respondent is likely to have.« less

  15. Environmental enrichment of brown capuchins (Cebus apella): behavioral and plasma and fecal cortisol measures of effectiveness.

    PubMed

    Boinski, S; Swing, S P; Gross, T S; Davis, J K

    1999-01-01

    No consensus exists about the quantity and variety of environmental enrichment needed to achieve an acceptable level of psychological well-being among singly housed primates. Behavioral and plasma and fecal cortisol measures were used to evaluate the effectiveness of four levels of toy and foraging enrichment provided to eight wild-caught, singly housed adult male brown capuchins (Cebus apella). The 16-week-long study comprised six conditions and began with a 4-week-long preexperimental and ended with a 4-week-long postexperimental period during which the subjects were maintained at baseline enrichment levels. During the intervening 8 weeks, the subjects were randomly assigned to a sequence of four 2-week-long experimental conditions: control (baseline conditions), toy (the addition of two plastic toys to each cage), box (access to a foraging box with food treats hidden within crushed alfalfa), and box & toy (the addition of two plastic toys and access to a foraging box). Behavioral responses to changes in enrichment were rapid and extensive. Within-subject repeated-measure ANOVAs with planned post hoc contrasts identified highly significant reductions in abnormal and undesirable behaviors (and increases in normal behaviors) as the level of enrichment increased from control to toy to box to box & toy. No significant behavioral differences were found between the control and pre- and postexperimental conditions. Plasma and fecal cortisol measures revealed a different response to changing enrichment levels. Repeated-measure ANOVA models found significant changes in both these measures across the six conditions. The planned post hoc analyses, however, while finding dramatic increases in cortisol titers in both the pre- and postexperimental conditions relative to the control condition, did not distinguish cortisol responses among the four enrichment levels. Linear regressions among weekly group means in behavioral and cortisol measures (n=16) found that plasma cortisol

  16. Environmental enrichment of brown capuchins (Cebus apella): Behavioral and plasma and fecal cortisol measures of effectiveness

    USGS Publications Warehouse

    Boinski, S.; Swing, S.P.; Gross, T.S.; Davis, J.K.

    1999-01-01

    No consensus exists about the quantity and variety of environmental enrichment needed to achieve an acceptable level of psychological well-being among singly housed primates. Behavioral and plasma and fecal cortisol measures were used to evaluate the effectiveness of four levels of toy and foraging enrichment provided to eight wild-caught, singly housed adult male brown capuchins (Cebus apella). The 16-week-long study comprised six conditions and began with a 4-week-long preexperimental and ended with a 4-week-long postexperimental period during which the subjects were maintained at baseline enrichment levels. During the intervening 8 weeks, the subjects were randomly assigned to a sequence of four 2-week-long experimental conditions: control (baseline conditions), toy (the addition of two plastic toys to each cage), box (access to a foraging box with food treats hidden within crushed alfalfa), and box and toy (the addition of two plastic toys and access to a foraging box). Behavioral responses to changes in enrichment were rapid and extensive. Within-subject repeated-measure ANOVAs with planned post hoc contrasts identified highly significant reductions in abnormal and undesirable behaviors (and increases in normal behaviors) as the level of enrichment increased from control to toy to box to box and toy. No significant behavioral differences were found between the control and pre- and postexperimental conditions. Plasma and fecal cortisol measures revealed a different response to changing enrichment levels. Repeated-measure ANOVA models found significant changes in both these measures across the six conditions. The planned post hoc analyses, however, while finding dramatic increases in cortisol titers in both the pre- and postexperimental conditions relative to the control condition, did not distinguish cortisol responses among the four enrichment levels. Linear regressions among weekly group means in behavioral and cortisol measures (n = 16) found that plasma

  17. Some generalization and follow-up measures on autistic children in behavior therapy1

    PubMed Central

    Lovaas, O. Ivar; Koegel, Robert; Simmons, James Q.; Long, Judith Stevens

    1973-01-01

    We have treated 20 autistic children with behavior therapy. At intake, most of the children were severely disturbed, having symptoms indicating an extremely poor prognosis. The children were treated in separate groups, and some were treated more than once, allowing for within- and between-subject replications of treatment effects. We have employed reliable measures of generalization across situations and behaviors as well as across time (follow-up). The findings can be summarized as follows: (1) Inappropriate behaviors (self-stimulation and echolalia) decreased during treatment, and appropriate behaviors (appropriate speech, appropriate play, and social non-verbal behaviors) increased. (2) Spontaneous social interactions and the spontaneous use of language occurred about eight months into treatment for some of the children. (3) IQs and social quotients reflected improvement during treatment. (4) There were no exceptions to the improvement, however, some of the children improved more than others. (5) Follow-up measures recorded 1 to 4 yr after treatment showed that large differences between groups of children depended upon the post-treatment environment (those groups whose parents were trained to carry out behavior therapy continued to improve, while children who were institutionalized regressed). (6) A brief reinstatement of behavior therapy could temporarily re-establish some of the original therapeutic gains made by the children who were subsequently institutionalized. PMID:16795385

  18. Instrument accurately measures weld angle and offset

    NASA Technical Reports Server (NTRS)

    Boyd, W. G.

    1967-01-01

    Weld angle is measured to the nearest arc minute and offset to one thousandth of an inch by an instrument designed to use a reference plane at two locations on a test coupon. A special table for computation has been prepared for use with the instrument.

  19. Estimating the state of a geophysical system with sparse observations: time delay methods to achieve accurate initial states for prediction

    NASA Astrophysics Data System (ADS)

    An, Zhe; Rey, Daniel; Ye, Jingxin; Abarbanel, Henry D. I.

    2017-01-01

    The problem of forecasting the behavior of a complex dynamical system through analysis of observational time-series data becomes difficult when the system expresses chaotic behavior and the measurements are sparse, in both space and/or time. Despite the fact that this situation is quite typical across many fields, including numerical weather prediction, the issue of whether the available observations are "sufficient" for generating successful forecasts is still not well understood. An analysis by Whartenby et al. (2013) found that in the context of the nonlinear shallow water equations on a β plane, standard nudging techniques require observing approximately 70 % of the full set of state variables. Here we examine the same system using a method introduced by Rey et al. (2014a), which generalizes standard nudging methods to utilize time delayed measurements. We show that in certain circumstances, it provides a sizable reduction in the number of observations required to construct accurate estimates and high-quality predictions. In particular, we find that this estimate of 70 % can be reduced to about 33 % using time delays, and even further if Lagrangian drifter locations are also used as measurements.

  20. The Convergent Validities of Two Measures of Dating Behaviors Related to Risk for Sexual Victimization

    ERIC Educational Resources Information Center

    Breitenbecher, Kimberly Hanson

    2008-01-01

    The primary purpose of this investigation was to assess the convergent validities of two measures of dating behaviors related to risk for sexual victimization, the Dating Self-Protection Against Rape Scale (DSPARS) and the Dating Behavior Survey (DBS). Three hundred seventy-seven women responded to measures assessing self-protective dating…

  1. Speech-Processing Fatigue in Children: Auditory Event-Related Potential and Behavioral Measures

    PubMed Central

    Gustafson, Samantha J.; Rentmeester, Lindsey; Hornsby, Benjamin W. Y.; Bess, Fred H.

    2017-01-01

    Purpose Fatigue related to speech processing is an understudied area that may have significant negative effects, especially in children who spend the majority of their school days listening to classroom instruction. Method This study examined the feasibility of using auditory P300 responses and behavioral indices (lapses of attention and self-report) to measure fatigue resulting from sustained listening demands in 27 children (M = 9.28 years). Results Consistent with predictions, increased lapses of attention, longer reaction times, reduced P300 amplitudes to infrequent target stimuli, and self-report of greater fatigue were observed after the completion of a series of demanding listening tasks compared with the baseline values. The event-related potential responses correlated with the behavioral measures of performance. Conclusion These findings suggest that neural and behavioral responses indexing attention and processing resources show promise as effective markers of fatigue in children. PMID:28595261

  2. Development and Validation of a Multidimensional Measure of Family Supportive Supervisor Behaviors (FSSB)

    PubMed Central

    Hammer, Leslie B.; Kossek, Ellen Ernst; Yragui, Nanette L.; Bodner, Todd E.; Hanson, Ginger C.

    2011-01-01

    Due to growing work-family demands, supervisors need to effectively exhibit family supportive supervisor behaviors (FSSB). Drawing on social support theory and using data from two samples of lower wage workers, the authors develop and validate a measure of FSSB, defined as behaviors exhibited by supervisors that are supportive of families. FSSB is conceptualized as a multidimensional superordinate construct with four subordinate dimensions: emotional support, instrumental support, role modeling behaviors, and creative work-family management. Results from multilevel confirmatory factor analyses and multilevel regression analyses provide evidence of construct, criterion-related, and incremental validity. The authors found FSSB to be significantly related to work-family conflict, work-family positive spillover, job satisfaction, and turnover intentions over and above measures of general supervisor support. PMID:21660254

  3. Alcohol operant self-administration: Investigating how alcohol-seeking behaviors predict drinking in mice using two operant approaches

    PubMed Central

    Blegen, Mariah B.; Silva, Daniel da Silva E; Bock, Roland; Morisot, Nadege; Ron, Dorit; Alvarez, Veronica A.

    2018-01-01

    Alcohol operant self-administration paradigms are critical tools for studying the neural circuits implicated in both alcohol-seeking and consummatory behaviors and for understanding the neural basis underlying alcohol-use disorders. In this study, we investigate the predictive value of two operant models of oral alcohol self-administration in mice, one in which alcohol is delivered into a cup following nose-poke responses with no accurate measurement of consumed alcohol solution, and another paradigm that provides access to alcohol via a sipper tube following lever presses and where lick rate and consumed alcohol volume can be measured. The goal was to identify a paradigm where operant behaviors such as lever presses and nose pokes, as well as other tracked behavior such as licks and head entries, can be used to reliably predict blood alcohol concentration (BAC). All mice were first exposed to alcohol in the home cage using the “drinking in the dark” (DID) procedure for 3 weeks and then were trained in alcohol self-administration using either of the operant paradigms for several weeks. Even without sucrose fading or food pre-training, mice acquired alcohol self-administration with both paradigms. However, neither lever press nor nose-poke rates were good predictors of alcohol intake or BAC. Only the lick rate and consumed alcohol were consistently and significantly correlated with BAC. Using this paradigm that accurately measures alcohol intake, unsupervised cluster analysis revealed three groups of mice: high-drinking (43%), low-drinking (37%), and non-drinking mice (20%). High-drinking mice showed faster acquisition of operant responding and achieved higher BACs than low-drinking mice. Lick rate and volume consumed varied with the alcohol concentration made available only for high- and low-drinking mice, but not for non-drinking mice. In addition, high- and low-drinking mice showed similar patterns during extinction and significant cue-induced reinstatement

  4. Electrophysiological gap detection thresholds: effects of age and comparison with a behavioral measure.

    PubMed

    Palmer, Shannon B; Musiek, Frank E

    2014-01-01

    Temporal processing ability has been linked to speech understanding ability and older adults often complain of difficulty understanding speech in difficult listening situations. Temporal processing can be evaluated using gap detection procedures. There is some research showing that gap detection can be evaluated using an electrophysiological procedure. However, there is currently no research establishing gap detection threshold using the N1-P2 response. The purposes of the current study were to 1) determine gap detection thresholds in younger and older normal-hearing adults using an electrophysiological measure, 2) compare the electrophysiological gap detection threshold and behavioral gap detection threshold within each group, and 3) investigate the effect of age on each gap detection measure. This study utilized an older adult group and younger adult group to compare performance on an electrophysiological and behavioral gap detection procedure. The subjects in this study were 11 younger, normal-hearing adults (mean = 22 yrs) and 11 older, normal-hearing adults (mean = 64.36 yrs). All subjects completed an adaptive behavioral gap detection procedure in order to determine their behavioral gap detection threshold (BGDT). Subjects also completed an electrophysiologic gap detection procedure to determine their electrophysiologic gap detection threshold (EGDT). Older adults demonstrated significantly larger gap detection thresholds than the younger adults. However, EGDT and BGDT were not significantly different in either group. The mean difference between EGDT and BGDT for all subjects was 0.43 msec. Older adults show poorer gap detection ability when compared to younger adults. However, this study shows that gap detection thresholds can be measured using evoked potential recordings and yield results similar to a behavioral measure. American Academy of Audiology.

  5. Displacement activities as a behavioral measure of stress in nonhuman primates and human subjects.

    PubMed

    Troisi, Alfonso

    2002-02-01

    Traditionally, research on human stress has relied mostly on physiological and psychological measures with a relatively minor emphasis on the behavioral aspects of the phenomenon. Such an approach makes it difficult to develop valid animal models of the human stress syndrome. A promising approach to the study of the behavioral correlates of stress is to analyze those behavior patterns that ethologists have named displacement activities and that, in primates, consist mostly of self-directed behaviors. In both nonhuman primates and human subjects, displacement behavior appears in situations characterized by social tension and is likely to reflect increased autonomic arousal. Pharmacological studies of nonhuman primates have shown that the frequency of occurrence of displacement behavior is increased by anxiogenic compounds and decreased by anxiolytic drugs. Ethological studies of healthy persons and psychiatric patients during interviews have found that increased displacement behavior not only correlates with a subjective feeling state of anxiety and negative affect but also gives more veridical information about the subject's emotional state than verbal statements and facial expression. The measurement of displacement activities may be a useful complement to the physiological and psychological studies aimed at analyzing the correlates and consequences of stress.

  6. Construct Validation of a Measure to Assess Sustainability of School-Wide Behavior Interventions

    ERIC Educational Resources Information Center

    Hume, Amanda; McIntosh, Kent

    2013-01-01

    This study assessed aspects of construct validity of the School-wide Universal Behavior Sustainability Index-School Teams (SUBSIST), a measure evaluating critical features of the school context related to sustainability of school-wide interventions. Participants at 217 schools implementing School-wide Positive Behavior Support (SWPBS) were…

  7. Comparison between objective measures and parental behavioral rating scales of memory and attention in pediatric endocrinology patients.

    PubMed

    Limbers, Christine; Young, Danielle; Jernigan, Stephanie; Bryant, William; Stephen, Matt

    2017-01-01

    Behavioral rating scales represent one potential method for screening of cognitive functioning in routine clinical care. It is not yet known if objective performance based measures and behavioral rating scales of cognitive functioning completed by parents yield similar information in pediatric endocrinology patients. The purpose of the present study was to evaluate the associations between performance-based measures and behavioral rating scales of memory and attention/concentration completed by parents of pediatric patients with Type 1 Diabetes or obesity. The sample consisted of 73 pediatric patients with Type 1 Diabetes or obesity (BMI > 95th percentile) ages 6-16 years (mean age = 12.29 years) referred to an outpatient pediatric endocrinology clinic. Youth were administered the Wide Range Assessment of Memory and Learning (WRAML-2). Parents completed the Child Behavior Checklist (CBCL) and the PedsQL Cognitive Functioning Scale. Pearson's Product Moment Correlations were examined among the performance-based measures and behavioral rating scales. All intercorrelations between the performance-based measures and behavioral rating scales completed by parents were in the small range. The only statistically significant (P < 0.05) and approaching medium correlation was between the PedsQL Cognitive Functioning Scale and WRAML-2 Verbal Memory Index (r = 0.28). On behavioral rating scales and performance-based measures of visual memory and attention/concentration, our sample exhibited greater difficulties than healthy youth from previously published data (P < 0.05). One possible explanation for our findings is that behavioral rating scales of attention/concentration and memory completed by parents measure different aspects of cognitive functioning than performance based measures in pediatric patients with Type 1 Diabetes or obesity.

  8. Multilevel Interventions: Measurement and Measures

    PubMed Central

    Charns, Martin P.; Alligood, Elaine C.; Benzer, Justin K.; Burgess, James F.; Mcintosh, Nathalie M.; Burness, Allison; Partin, Melissa R.; Clauser, Steven B.

    2012-01-01

    Background Multilevel intervention research holds the promise of more accurately representing real-life situations and, thus, with proper research design and measurement approaches, facilitating effective and efficient resolution of health-care system challenges. However, taking a multilevel approach to cancer care interventions creates both measurement challenges and opportunities. Methods One-thousand seventy two cancer care articles from 2005 to 2010 were reviewed to examine the state of measurement in the multilevel intervention cancer care literature. Ultimately, 234 multilevel articles, 40 involving cancer care interventions, were identified. Additionally, literature from health services, social psychology, and organizational behavior was reviewed to identify measures that might be useful in multilevel intervention research. Results The vast majority of measures used in multilevel cancer intervention studies were individual level measures. Group-, organization-, and community-level measures were rarely used. Discussion of the independence, validity, and reliability of measures was scant. Discussion Measurement issues may be especially complex when conducting multilevel intervention research. Measurement considerations that are associated with multilevel intervention research include those related to independence, reliability, validity, sample size, and power. Furthermore, multilevel intervention research requires identification of key constructs and measures by level and consideration of interactions within and across levels. Thus, multilevel intervention research benefits from thoughtful theory-driven planning and design, an interdisciplinary approach, and mixed methods measurement and analysis. PMID:22623598

  9. Extrinsic labeling method may not accurately measure Fe absorption from cooked pinto beans (Phaseolus vulgaris): comparison of extrinsic and intrinsic labeling of beans.

    PubMed

    Jin, Fuxia; Cheng, Zhiqiang; Rutzke, Michael A; Welch, Ross M; Glahn, Raymond P

    2008-08-27

    Isotopic labeling of food has been widely used for the measurement of Fe absorption in determining requirements and evaluating the factors involved in Fe bioavailability. An extrinsic labeling technique will not accurately predict the total Fe absorption from foods unless complete isotopic exchange takes place between an extrinsically added isotope label and the intrinsic Fe of the food. We examined isotopic exchange in the case of both white beans and colored beans (Phaseolus vulgaris) with an in vitro digestion model. There are significant differences in (58)Fe/(56)Fe ratios between the sample digest supernatant and the pellet of extrinsically labeled pinto bean. The white bean digest shows significantly better equilibration of the extrinsic (58)Fe with the intrinsic (56)Fe. In contrast to the extrinsically labeled samples, both white and red beans labeled intrinsically with (58)Fe demonstrated consistent ratios of (58)Fe/(56)Fe in the bean meal, digest, supernatant, and pellet. It is possible that the polyphenolics in the bean seed coat may bind Fe and thus interfere with extrinsic labeling of the bean meals. These observations raise questions on the accuracy of studies that used extrinsic tags to measure Fe absorption from beans. Intrinsic labeling appears necessary to accurately measure Fe bioavailability from beans.

  10. On canonical cylinder sections for accurate determination of contact angle in microgravity

    NASA Technical Reports Server (NTRS)

    Concus, Paul; Finn, Robert; Zabihi, Farhad

    1992-01-01

    Large shifts of liquid arising from small changes in certain container shapes in zero gravity can be used as a basis for accurately determining contact angle. Canonical geometries for this purpose, recently developed mathematically, are investigated here computationally. It is found that the desired nearly-discontinuous behavior can be obtained and that the shifts of liquid have sufficient volume to be readily observed.

  11. Sedentary behavior and sleep: paradoxical effects in association with childhood obesity.

    PubMed

    Must, A; Parisi, S M

    2009-04-01

    Sedentary behavior and sleep may be working in concert to increase the likelihood of a child becoming overweight, but in paradoxical ways. Reduction of sedentary behavior (that is, media screen time) has been extensively researched and touted as an intervention target. Inadequate sleep as a putative risk factor for obesity is only beginning to be explored. In this paper, we review the current state of research regarding these factors, and describe the existing evidence and mechanisms proposed to explain these relationships. Whereas the association between weight and sedentary behavior has been consistently shown in observational studies, effect sizes are small, and multiple mechanisms appear to be operating. Recent cross-sectional and longitudinal evidence suggests a link between short sleep duration and weight. Possible mechanisms here include direct metabolic effects as well as indirect behavioral pathways, including the presence of electronic media in children's bedrooms. Measurement issues present a challenge to both areas of research. Prospective studies that include more accurate measures of both sedentary behavior and of sleep will be needed to clarify causal pathways.

  12. Accurate Descriptions of Hot Flow Behaviors Across β Transus of Ti-6Al-4V Alloy by Intelligence Algorithm GA-SVR

    NASA Astrophysics Data System (ADS)

    Wang, Li-yong; Li, Le; Zhang, Zhi-hua

    2016-09-01

    Hot compression tests of Ti-6Al-4V alloy in a wide temperature range of 1023-1323 K and strain rate range of 0.01-10 s-1 were conducted by a servo-hydraulic and computer-controlled Gleeble-3500 machine. In order to accurately and effectively characterize the highly nonlinear flow behaviors, support vector regression (SVR) which is a machine learning method was combined with genetic algorithm (GA) for characterizing the flow behaviors, namely, the GA-SVR. The prominent character of GA-SVR is that it with identical training parameters will keep training accuracy and prediction accuracy at a stable level in different attempts for a certain dataset. The learning abilities, generalization abilities, and modeling efficiencies of the mathematical regression model, ANN, and GA-SVR for Ti-6Al-4V alloy were detailedly compared. Comparison results show that the learning ability of the GA-SVR is stronger than the mathematical regression model. The generalization abilities and modeling efficiencies of these models were shown as follows in ascending order: the mathematical regression model < ANN < GA-SVR. The stress-strain data outside experimental conditions were predicted by the well-trained GA-SVR, which improved simulation accuracy of the load-stroke curve and can further improve the related research fields where stress-strain data play important roles, such as speculating work hardening and dynamic recovery, characterizing dynamic recrystallization evolution, and improving processing maps.

  13. Accurate position estimation methods based on electrical impedance tomography measurements

    NASA Astrophysics Data System (ADS)

    Vergara, Samuel; Sbarbaro, Daniel; Johansen, T. A.

    2017-08-01

    than 0.05% of the tomograph radius value. These results demonstrate that the proposed approaches can estimate an object’s position accurately based on EIT measurements if enough process information is available for training or modelling. Since they do not require complex calculations it is possible to use them in real-time applications without requiring high-performance computers.

  14. The Relationship between Attitudinal and Behavioral Measures of Sex Preference.

    ERIC Educational Resources Information Center

    Calway-Fagen, Norma; And Others

    1979-01-01

    Examined the relationship between an attitudinal and a behavioral measure of sex-preference for offspring. Contrary to prediction, androgynous and nonandrogynous persons did not differ significantly on preferred sex of child. Persons with a more positive attitude toward women's movement ideology showed significantly less male preference. (Author)

  15. Anthropometric and Behavioral Measures Related to Mindfulness in College Students

    ERIC Educational Resources Information Center

    Grinnell, Sarah; Greene, Geoffrey; Melanson, Kathleen; Blissmer, Bryan; Lofgren, Ingrid E.

    2011-01-01

    Objective: To determine whether mindfulness is associated with physical and behavioral measures in first semester college students. Participants: Male and female first year college students (n = 75) from the University of Rhode Island. Methods: Height, weight, waist circumference (WC), and blood pressure were assessed and online questionnaires…

  16. Operationalizing the Measurement of Seroadaptive Behaviors: A Comparison of Reported Sexual Behaviors and Purposely-Adopted Behaviors Among Men who have Sex with Men (MSM) in Seattle.

    PubMed

    Khosropour, Christine M; Dombrowski, Julia C; Hughes, James P; Manhart, Lisa E; Simoni, Jane M; Golden, Matthew R

    2017-10-01

    Seroadaptive behaviors are traditionally defined by self-reported sexual behavior history, regardless of whether they reflect purposely-adopted risk-mitigation strategies. Among MSM attending an STD clinic in Seattle, Washington 2013-2015 (N = 3751 visits), we used two seroadaptive behavior measures: (1) sexual behavior history reported via clinical computer-assisted self-interview (CASI) (behavioral definition); (2) purposely-adopted risk-reduction behaviors reported via research CASI (purposely-adopted definition). Pure serosorting (i.e. only HIV-concordant partners) was the most common behavior, reported (behavioral and purposely-adopted definition) by HIV-negative respondents at 43% and 60% of visits, respectively (kappa = 0.24; fair agreement) and by HIV-positive MSM at 30 and 34% (kappa = 0.25; fair agreement). Agreement of the two definitions was highest for consistent condom use [HIV-negative men (kappa = 0.72), HIV-positive men (kappa = 0.57)]. Overall HIV test positivity was 1.4 but 0.9% for pure serosorters. The two methods of operationalizing behaviors result in different estimates, thus the choice of which to employ should depend on the motivation for ascertaining behavioral information.

  17. The TiltMeter app is a novel and accurate measurement tool for the weight bearing lunge test.

    PubMed

    Williams, Cylie M; Caserta, Antoni J; Haines, Terry P

    2013-09-01

    The weight bearing lunge test is increasing being used by health care clinicians who treat lower limb and foot pathology. This measure is commonly established accurately and reliably with the use of expensive equipment. This study aims to compare the digital inclinometer with a free app, TiltMeter on an Apple iPhone. This was an intra-rater and inter-rater reliability study. Two raters (novice and experienced) conducted the measurements in both a bent knee and straight leg position to determine the intra-rater and inter-rater reliability. Concurrent validity was also established. Allied health practitioners were recruited as participants from the workplace. A preconditioning stretch was conducted and the ankle range of motion was established with the weight bearing lunge test position with firstly the leg straight and secondly with the knee bent. The measurement device and each participant were randomised during measurement. The intra-rater reliability and inter-rater reliability for the devices and in both positions were all over ICC 0.8 except for one intra-rater measure (Digital inclinometer, novice, ICC 0.65). The inter-rater reliability between the digital inclinometer and the tilmeter was near perfect, ICC 0.96 (CI: 0.898-0.983); Concurrent validity ICC between the two devices was 0.83 (CI: -0.740 to 0.445). The use of the Tiltmeter app on the iPhone is a reliable and inexpensive tool to measure the available ankle range of motion. Health practitioners should use caution in applying these findings to other smart phone equipment if surface areas are not comparable. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  18. Using Copula Distributions to Support More Accurate Imaging-Based Diagnostic Classifiers for Neuropsychiatric Disorders

    PubMed Central

    Bansal, Ravi; Hao, Xuejun; Liu, Jun; Peterson, Bradley S.

    2014-01-01

    Many investigators have tried to apply machine learning techniques to magnetic resonance images (MRIs) of the brain in order to diagnose neuropsychiatric disorders. Usually the number of brain imaging measures (such as measures of cortical thickness and measures of local surface morphology) derived from the MRIs (i.e., their dimensionality) has been large (e.g. >10) relative to the number of participants who provide the MRI data (<100). Sparse data in a high dimensional space increases the variability of the classification rules that machine learning algorithms generate, thereby limiting the validity, reproducibility, and generalizability of those classifiers. The accuracy and stability of the classifiers can improve significantly if the multivariate distributions of the imaging measures can be estimated accurately. To accurately estimate the multivariate distributions using sparse data, we propose to estimate first the univariate distributions of imaging data and then combine them using a Copula to generate more accurate estimates of their multivariate distributions. We then sample the estimated Copula distributions to generate dense sets of imaging measures and use those measures to train classifiers. We hypothesize that the dense sets of brain imaging measures will generate classifiers that are stable to variations in brain imaging measures, thereby improving the reproducibility, validity, and generalizability of diagnostic classification algorithms in imaging datasets from clinical populations. In our experiments, we used both computer-generated and real-world brain imaging datasets to assess the accuracy of multivariate Copula distributions in estimating the corresponding multivariate distributions of real-world imaging data. Our experiments showed that diagnostic classifiers generated using imaging measures sampled from the Copula were significantly more accurate and more reproducible than were the classifiers generated using either the real-world imaging

  19. Validated Measures of Illness Perception and Behavior in People with Knee Pain and Knee Osteoarthritis: A Scoping Review.

    PubMed

    Hamilton, Clayon B; Wong, Ming-Kin; Gignac, Monique A M; Davis, Aileen M; Chesworth, Bert M

    2017-01-01

    To identify validated measures that capture illness perception and behavior and have been used to assess people who have knee pain/osteoarthritis. A scoping review was performed. Nine electronic databases were searched for records from inception through April 19, 2015. Search terms included illness perception, illness behavior, knee, pain, osteoarthritis, and their related terms. This review included English language publications of primary data on people with knee pain/osteoarthritis who were assessed with validated measures capturing any of 4 components of illness perception and behavior: monitor body, define and interpret symptoms, take remedial action, and utilize sources of help. Seventy-one publications included relevant measures. Two reviewers independently coded and analyzed each relevant measure within the 4 components. Sixteen measures were identified that capture components of illness perception and behavior in the target population. These measures were originally developed to capture constructs that include coping strategies/skills/styles, illness belief, illness perception, self-efficacy, and pain behavior. Coding results indicated that 5, 11, 12, and 5 of these measures included the monitor body, define and interpret symptoms, take remedial action, and utilize sources of help components, respectively. Several validated measures were interpreted as capturing some components, and only 1 measure was interpreted as capturing all of the components of illness perception and behavior in the target population. A measure that comprehensively captures illness perception and behavior could be valuable for informing and evaluating therapy for patients along a continuum of symptomatic knee osteoarthritis. © 2016 World Institute of Pain.

  20. Relations among behavioral and questionnaire measures of impulsivity in a sample of suicide attempters.

    PubMed

    Bagge, Courtney L; Littlefield, Andrew K; Rosellini, Anthony J; Coffey, Scott F

    2013-08-01

    Despite the focus on impulsivity within suicide research, it remains unclear the extent to which impulsivity assessments, that purportedly tap similar constructs, show significant overlap in samples of individuals with suicidal behaviors. In a sample of 69 suicide attempters, we took a multitrait, multimethod approach to examine the relation among various questionnaire and behavioral assessments of impulsivity facets. With the exception of urgency and go-stop performance, there was little evidence of concordance between questionnaire and behavioral measures. These findings suggest researchers cannot presume that measures of "impulsivity" assess similar psychological processes and that more nuanced terminology is needed. © 2013 The American Association of Suicidology.

  1. Objectively measured sedentary behavior in preschool children: comparison between Montessori and traditional preschools.

    PubMed

    Byun, Wonwoo; Blair, Steven N; Pate, Russell R

    2013-01-03

    This study aimed to compare the levels of objectively-measured sedentary behavior in children attending Montessori preschools with those attending traditional preschools. The participants in this study were preschool children aged 4 years old who were enrolled in Montessori and traditional preschools. The preschool children wore ActiGraph accelerometers. Accelerometers were initialized using 15-second intervals and sedentary behavior was defined as <200 counts/15-second. The accelerometry data were summarized into the average minutes per hour spent in sedentary behavior during the in-school, the after-school, and the total-day period. Mixed linear regression models were used to determine differences in the average time spent in sedentary behavior between children attending traditional and Montessori preschools, after adjusting for selected potential correlates of preschoolers' sedentary behavior. Children attending Montessori preschools spent less time in sedentary behavior than those attending traditional preschools during the in-school (44.4. min/hr vs. 47.1 min/hr, P = 0.03), after-school (42.8. min/hr vs. 44.7 min/hr, P = 0.04), and total-day (43.7 min/hr vs. 45.5 min/hr, P = 0. 009) periods. School type (Montessori or traditional), preschool setting (private or public), socio-demographic factors (age, gender, and socioeconomic status) were found to be significant predictors of preschoolers' sedentary behavior. Levels of objectively-measured sedentary behavior were significantly lower among children attending Montessori preschools compared to children attending traditional preschools. Future research should examine the specific characteristics of Montessori preschools that predict the lower levels of sedentary behavior among children attending these preschools compared to children attending traditional preschools.

  2. Objectively measured sedentary behavior in preschool children: comparison between Montessori and traditional preschools

    PubMed Central

    2013-01-01

    Background This study aimed to compare the levels of objectively-measured sedentary behavior in children attending Montessori preschools with those attending traditional preschools. Methods The participants in this study were preschool children aged 4 years old who were enrolled in Montessori and traditional preschools. The preschool children wore ActiGraph accelerometers. Accelerometers were initialized using 15-second intervals and sedentary behavior was defined as <200 counts/15-second. The accelerometry data were summarized into the average minutes per hour spent in sedentary behavior during the in-school, the after-school, and the total-day period. Mixed linear regression models were used to determine differences in the average time spent in sedentary behavior between children attending traditional and Montessori preschools, after adjusting for selected potential correlates of preschoolers’ sedentary behavior. Results Children attending Montessori preschools spent less time in sedentary behavior than those attending traditional preschools during the in-school (44.4. min/hr vs. 47.1 min/hr, P = 0.03), after-school (42.8. min/hr vs. 44.7 min/hr, P = 0.04), and total-day (43.7 min/hr vs. 45.5 min/hr, P = 0. 009) periods. School type (Montessori or traditional), preschool setting (private or public), socio-demographic factors (age, gender, and socioeconomic status) were found to be significant predictors of preschoolers’ sedentary behavior. Conclusions Levels of objectively-measured sedentary behavior were significantly lower among children attending Montessori preschools compared to children attending traditional preschools. Future research should examine the specific characteristics of Montessori preschools that predict the lower levels of sedentary behavior among children attending these preschools compared to children attending traditional preschools. PMID:23286454

  3. Accurate Permittivity Measurements for Microwave Imaging via Ultra-Wideband Removal of Spurious Reflectors

    PubMed Central

    Pelletier, Mathew G.; Viera, Joseph A.; Wanjura, John; Holt, Greg

    2010-01-01

    The use of microwave imaging is becoming more prevalent for detection of interior hidden defects in manufactured and packaged materials. In applications for detection of hidden moisture, microwave tomography can be used to image the material and then perform an inverse calculation to derive an estimate of the variability of the hidden material, such internal moisture, thereby alerting personnel to damaging levels of the hidden moisture before material degradation occurs. One impediment to this type of imaging occurs with nearby objects create strong reflections that create destructive and constructive interference, at the receiver, as the material is conveyed past the imaging antenna array. In an effort to remove the influence of the reflectors, such as metal bale ties, research was conducted to develop an algorithm for removal of the influence of the local proximity reflectors from the microwave images. This research effort produced a technique, based upon the use of ultra-wideband signals, for the removal of spurious reflections created by local proximity reflectors. This improvement enables accurate microwave measurements of moisture in such products as cotton bales, as well as other physical properties such as density or material composition. The proposed algorithm was shown to reduce errors by a 4:1 ratio and is an enabling technology for imaging applications in the presence of metal bale ties. PMID:22163668

  4. Accurate permittivity measurements for microwave imaging via ultra-wideband removal of spurious reflectors.

    PubMed

    Pelletier, Mathew G; Viera, Joseph A; Wanjura, John; Holt, Greg

    2010-01-01

    The use of microwave imaging is becoming more prevalent for detection of interior hidden defects in manufactured and packaged materials. In applications for detection of hidden moisture, microwave tomography can be used to image the material and then perform an inverse calculation to derive an estimate of the variability of the hidden material, such internal moisture, thereby alerting personnel to damaging levels of the hidden moisture before material degradation occurs. One impediment to this type of imaging occurs with nearby objects create strong reflections that create destructive and constructive interference, at the receiver, as the material is conveyed past the imaging antenna array. In an effort to remove the influence of the reflectors, such as metal bale ties, research was conducted to develop an algorithm for removal of the influence of the local proximity reflectors from the microwave images. This research effort produced a technique, based upon the use of ultra-wideband signals, for the removal of spurious reflections created by local proximity reflectors. This improvement enables accurate microwave measurements of moisture in such products as cotton bales, as well as other physical properties such as density or material composition. The proposed algorithm was shown to reduce errors by a 4:1 ratio and is an enabling technology for imaging applications in the presence of metal bale ties.

  5. Tomosynthesis can facilitate accurate measurement of joint space width under the condition of the oblique incidence of X-rays in patients with rheumatoid arthritis.

    PubMed

    Ono, Yohei; Kashihara, Rina; Yasojima, Nobutoshi; Kasahara, Hideki; Shimizu, Yuka; Tamura, Kenichi; Tsutsumi, Kaori; Sutherland, Kenneth; Koike, Takao; Kamishima, Tamotsu

    2016-06-01

    Accurate evaluation of joint space width (JSW) is important in the assessment of rheumatoid arthritis (RA). In clinical radiography of bilateral hands, the oblique incidence of X-rays is unavoidable, which may cause perceptional or measurement error of JSW. The objective of this study was to examine whether tomosynthesis, a recently developed modality, can facilitate a more accurate evaluation of JSW than radiography under the condition of oblique incidence of X-rays. We investigated quantitative errors derived from the oblique incidence of X-rays by imaging phantoms simulating various finger joint spaces using radiographs and tomosynthesis images. We then compared the qualitative results of the modified total Sharp score of a total of 320 joints from 20 patients with RA between these modalities. A quantitative error was prominent when the location of the phantom was shifted along the JSW direction. Modified total Sharp scores of tomosynthesis images were significantly higher than those of radiography, that is to say JSW was regarded as narrower in tomosynthesis than in radiography when finger joints were located where the oblique incidence of X-rays is expected in the JSW direction. Tomosynthesis can facilitate accurate evaluation of JSW in finger joints of patients with RA, even with oblique incidence of X-rays. Accurate evaluation of JSW is necessary for the management of patients with RA. Through phantom and clinical studies, we demonstrate that tomosynthesis may achieve more accurate evaluation of JSW.

  6. Accurate and stable equal-pressure measurements of water vapor transmission rate reaching the 10-6 g m-2 day-1 range

    NASA Astrophysics Data System (ADS)

    Nakano, Yoichiro; Yanase, Takashi; Nagahama, Taro; Yoshida, Hajime; Shimada, Toshihiro

    2016-10-01

    The water vapor transmission rate (WVTR) of a gas barrier coating is a critically important parameter for flexible organic device packaging, but its accurate measurement without mechanical stress to ultrathin films has been a significant challenge in instrumental analysis. At the current stage, no reliable results have been reported in the range of 10-6 g m-2 day-1 that is required for organic light emitting diodes (OLEDs). In this article, we describe a solution for this difficult, but important measurement, involving enhanced sensitivity by a cold trap, stabilized temperature system, pumped sealing and calibration by a standard conductance element.

  7. Measures of Consumer Satisfaction in Social Welfare and Behavioral Health: A Systematic Review

    ERIC Educational Resources Information Center

    Fraser, Mark W.; Wu, Shiyou

    2016-01-01

    This article reviews the origins, conceptual bases, psychometric properties, and limitations of consumer satisfaction measures in social welfare and behavioral health. Based on a systematic review of research reports published between 2003 and 2013, we identify 58 consumer satisfaction measures. On average, these measures have acceptable…

  8. 24 Hours of Sleep, Sedentary Behavior, and Physical Activity with Nine Wearable Devices

    PubMed Central

    Rosenberger, Mary E.; Buman, Matthew P.; Haskell, William L.; McConnell, Michael V.; Carstensen, Laura L.

    2015-01-01

    Getting enough sleep, exercising and limiting sedentary activities can greatly contribute to disease prevention and overall health and longevity. Measuring the full 24-hour activity cycle - sleep, sedentary behavior (SED), light intensity physical activity (LPA) and moderate-to-vigorous physical activity (MVPA) - may now be feasible using small wearable devices. PURPOSE This study compares nine devices for accuracy in 24-hour activity measurement. METHODS Adults (N=40, 47% male) wore nine devices for 24-hours: Actigraph GT3X+, activPAL, Fitbit One, GENEactiv, Jawbone Up, LUMOback, Nike Fuelband, Omron pedometer, and Z-Machine. Comparisons (to standards) were made for total sleep time (Z-machine), time spent in SED (activPAL), LPA (GT3x+), MVPA (GT3x+), and steps (Omron). Analysis included mean absolute percent error, equivalence testing, and Bland-Altman plots. RESULTS Error rates ranged from 8.1–16.9% for sleep; 9.5–65.8% for SED; 19.7–28.0% for LPA; 51.8–92% for MVPA; and 14.1–29.9% for steps. Equivalence testing indicated only two comparisons were significantly equivalent to standards: the LUMOback for sedentary behavior and the GT3X+ for sleep. Bland-Altman plots indicated GT3X+ had the closest measurement for sleep, LUMOback for sedentary behavior, GENEactiv for LPA, Fitbit for MVPA and GT3X+ for steps. CONCLUSIONS Currently, no device accurately captures activity data across the entire 24-hour day, but the future of activity measurement should aim for accurate 24-hour measurement as a goal. Researchers should continue to select measurement devices based on their primary outcomes of interest. PMID:26484953

  9. The Valued Living Questionnaire: Defining and Measuring Valued Action within a Behavioral Framework

    ERIC Educational Resources Information Center

    Wilson, Kelly G.; Sandoz, Emily K.; Kitchens, Jennifer; Roberts, Miguel

    2010-01-01

    A number of cognitive-behavior therapies now strongly emphasize particular behavioral processes as mediators of clinical change specific to that therapy. This shift in emphasis calls for the development of measures sensitive to changes in the therapies' processes. Among these is acceptance and commitment therapy (ACT), which posits valued living…

  10. The relationship between different measures of feed efficiency and feeding behavior traits in Duroc pigs.

    PubMed

    Lu, D; Jiao, S; Tiezzi, F; Knauer, M; Huang, Y; Gray, K A; Maltecca, C

    2017-08-01

    Utilization of feed in livestock species consists of a wide range of biological processes, and therefore, its efficiency can be expressed in various ways, including direct measurement, such as daily feed intake, as well as indicator measures, such as feeding behavior. Measuring feed efficiency is important to the swine industry, and its accuracy can be enhanced by using automated feeding systems, which record feed intake and associated feeding behavior of individual animals. Each automated feeder space is often shared among several pigs and therefore raises concerns about social interactions among pen mates with regard to feeding behavior. The study herein used a data set of 14,901 Duroc boars with individual records on feed intake, feeding behavior, and other off-test traits. These traits were modeled with and without the random spatial effect of Pen_Room, a concatenation of room and pen, or random social interaction among pen mates. The nonheritable spatial effect of common Pen-Room was observed for traits directly measuring feed intake and accounted for up to 13% of the total phenotypic variance in the average daily feeding rate. The social interaction effect explained larger proportions of phenotypic variation in all the traits studied, with the highest being 59% for ADFI in the group of feeding behaviors, 73% for residual feed intake (RFI; RFI4 and RFI6) in the feed efficiency traits, and 69% for intramuscular fat percentage in the off-test traits. After accounting for the social interaction effect, residual BW gain and RFI and BW gain (RIG) were found to have the heritability of 0.38 and 0.18, respectively, and had strong genetic correlations with growth and off-test traits. Feeding behavior traits were found to be moderately heritable, ranging from 0.14 (ADFI) to 0.52 (average daily occupation time), and some of them were strongly correlated with feed efficiency measures; for example, there was a genetic correlation of 0.88 between ADFI and RFI6. Our work

  11. Measures of fish behavior as indicators of sublethal toxicosis during standard toxicity tests

    USGS Publications Warehouse

    Little, E.E.; DeLonay, A.J.

    1996-01-01

    Behavioral functions essential for growth and survival can be dramatically altered by sublethal exposure to toxicants. Measures of these behavioral responses are effective in detecting adverse effects of sublethal contaminant exposure. Behavioral responses of fishes can be qualitatively and quantitatively evaluated during routine toxicity tests. At selected intervals of exposure, qualitative evaluations are accomplished through direct observations, whereas video recordings are used for quantitative evaluations. Standardized procedures for behavioral evaluation are readily applicable to different fish species and provide rapid, sensitive, and ecologically relevant assessments of sublethal exposure. The methods are readily applied to standardized test protocols.

  12. Work-related measures of physical and behavioral health function: Test-retest reliability.

    PubMed

    Marino, Molly Elizabeth; Meterko, Mark; Marfeo, Elizabeth E; McDonough, Christine M; Jette, Alan M; Ni, Pengsheng; Bogusz, Kara; Rasch, Elizabeth K; Brandt, Diane E; Chan, Leighton

    2015-10-01

    The Work Disability Functional Assessment Battery (WD-FAB), developed for potential use by the US Social Security Administration to assess work-related function, currently consists of five multi-item scales assessing physical function and four multi-item scales assessing behavioral health function; the WD-FAB scales are administered as Computerized Adaptive Tests (CATs). The goal of this study was to evaluate the test-retest reliability of the WD-FAB Physical Function and Behavioral Health CATs. We administered the WD-FAB scales twice, 7-10 days apart, to a sample of 376 working age adults and 316 adults with work-disability. Intraclass correlation coefficients were calculated to measure the consistency of the scores between the two administrations. Standard error of measurement (SEM) and minimal detectable change (MDC90) were also calculated to measure the scales precision and sensitivity. For the Physical Function CAT scales, the ICCs ranged from 0.76 to 0.89 in the working age adult sample, and 0.77-0.86 in the sample of adults with work-disability. ICCs for the Behavioral Health CAT scales ranged from 0.66 to 0.70 in the working age adult sample, and 0.77-0.80 in the adults with work-disability. The SEM ranged from 3.25 to 4.55 for the Physical Function scales and 5.27-6.97 for the Behavioral Health function scales. For all scales in both samples, the MDC90 ranged from 7.58 to 16.27. Both the Physical Function and Behavioral Health CATs of the WD-FAB demonstrated good test-retest reliability in adults with work-disability and general adult samples, a critical requirement for assessing work related functioning in disability applicants and in other contexts. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Work-related measures of Physical and Behavioral Health Function: Test-Retest Reliability

    PubMed Central

    Marino, Molly Elizabeth; Meterko, Mark; Marfeo, Elizabeth E.; McDonough, Christine M.; Jette, Alan M.; Ni, Pengsheng; Bogusz, Kara; Rasch, Elizabeth K.; Brandt, Diane E.; Chan, Leighton

    2015-01-01

    Background The Work Disability Functional Assessment Battery (WD-FAB), developed for potential use by the US Social Security Administration to assess work-related function, currently consists of five multi-item scales assessing physical function and four multi-item scales assessing behavioral health function; the WD-FAB scales are administered as Computerized Adaptive Tests (CATs). Objective The goal of this study was to evaluate the test-retest reliability of the WD-FAB Physical Function and Behavioral Health CATs. Methods We administered the WD-FAB scales twice, 7–10 days apart, to a sample of 376 working age adults and 316 adults with work-disability. Intraclass correlation coefficients were calculated to measure the consistency of the scores between the two administrations. Standard error of measurement (SEM) and minimal detectable change (MDC90) were also calculated to measure the scales precision and sensitivity. Results For the Physical Function CAT scales, the ICCs ranged from 0.76–0.89 in the working age adult sample, and 0.77–0.86 in the sample of adults with work-disability. ICCs for the Behavioral Health CAT scales ranged from 0.66–0.70 in the working age adult sample, and 0.77–0.80 in the adults with work-disability. The SEM ranged from 3.25–4.55 for the Physical Function scales and 5.27–6.97 for the Behavioral Health function scales. For all scales in both samples, the MDC90 ranged from 7.58–16.27. Conclusion Both the Physical Function and Behavioral Health CATs of the WD-FAB demonstrated good test-retest reliability in adults with work-disability and general adult samples, a critical requirement for assessing work related functioning in disability applicants and in other contexts. PMID:25991419

  14. Determinants of Sexual Network Structure and Their Impact on Cumulative Network Measures

    PubMed Central

    Schmid, Boris V.; Kretzschmar, Mirjam

    2012-01-01

    There are four major quantities that are measured in sexual behavior surveys that are thought to be especially relevant for the performance of sexual network models in terms of disease transmission. These are (i) the cumulative distribution of lifetime number of partners, (ii) the distribution of partnership durations, (iii) the distribution of gap lengths between partnerships, and (iv) the number of recent partners. Fitting a network model to these quantities as measured in sexual behavior surveys is expected to result in a good description of Chlamydia trachomatis transmission in terms of the heterogeneity of the distribution of infection in the population. Here we present a simulation model of a sexual contact network, in which we explored the role of behavioral heterogeneity of simulated individuals on the ability of the model to reproduce population-level sexual survey data from the Netherlands and UK. We find that a high level of heterogeneity in the ability of individuals to acquire and maintain (additional) partners strongly facilitates the ability of the model to accurately simulate the powerlaw-like distribution of the lifetime number of partners, and the age at which these partnerships were accumulated, as surveyed in actual sexual contact networks. Other sexual network features, such as the gap length between partnerships and the partnership duration, could–at the current level of detail of sexual survey data against which they were compared–be accurately modeled by a constant value (for transitional concurrency) and by exponential distributions (for partnership duration). Furthermore, we observe that epidemiological measures on disease prevalence in survey data can be used as a powerful tool for building accurate sexual contact networks, as these measures provide information on the level of mixing between individuals of different levels of sexual activity in the population, a parameter that is hard to acquire through surveying individuals. PMID

  15. Measuring and Modeling Behavioral Decision Dynamics in Collective Evacuation

    PubMed Central

    Carlson, Jean M.; Alderson, David L.; Stromberg, Sean P.; Bassett, Danielle S.; Craparo, Emily M.; Guiterrez-Villarreal, Francisco; Otani, Thomas

    2014-01-01

    Identifying and quantifying factors influencing human decision making remains an outstanding challenge, impacting the performance and predictability of social and technological systems. In many cases, system failures are traced to human factors including congestion, overload, miscommunication, and delays. Here we report results of a behavioral network science experiment, targeting decision making in a natural disaster. In a controlled laboratory setting, our results quantify several key factors influencing individual evacuation decision making in a controlled laboratory setting. The experiment includes tensions between broadcast and peer-to-peer information, and contrasts the effects of temporal urgency associated with the imminence of the disaster and the effects of limited shelter capacity for evacuees. Based on empirical measurements of the cumulative rate of evacuations as a function of the instantaneous disaster likelihood, we develop a quantitative model for decision making that captures remarkably well the main features of observed collective behavior across many different scenarios. Moreover, this model captures the sensitivity of individual- and population-level decision behaviors to external pressures, and systematic deviations from the model provide meaningful estimates of variability in the collective response. Identification of robust methods for quantifying human decisions in the face of risk has implications for policy in disasters and other threat scenarios, specifically the development and testing of robust strategies for training and control of evacuations that account for human behavior and network topologies. PMID:24520331

  16. From Knowledge to Action: Tips for Encouraging and Measuring Program-Related Behavior Change

    ERIC Educational Resources Information Center

    Chazdon, Scott; Horntvedt, Jody; Templin, Elizabeth

    2016-01-01

    It is challenging to document the behavior changes that result from Extension programming. This article describes an evaluation method we call the "action items method." Unlike other approaches for measuring behavior change, this method requires program participants to define their own action plans as part of a program and then asks them…

  17. Validation of a Behavioral Approach for Measuring Saccades in Parkinson's Disease.

    PubMed

    Turner, Travis H; Renfroe, Jenna B; Duppstadt-Delambo, Amy; Hinson, Vanessa K

    2017-01-01

    Speed and control of saccades are related to disease progression and cognitive functioning in Parkinson's disease (PD). Traditional eye-tracking complexities encumber application for individual evaluations and clinical trials. The authors examined psychometric properties of standalone tasks for reflexive prosaccade latency, volitional saccade initiation, and saccade inhibition (antisaccade) in a heterogeneous sample of 65 PD patients. Demographics had minimal impact on task performance. Thirty-day test-retest reliability estimates for behavioral tasks were acceptable and similar to traditional eye tracking. Behavioral tasks demonstrated concurrent validity with traditional eye-tracking measures; discriminant validity was less clear. Saccade initiation and inhibition discriminated PD patients with cognitive impairment. The present findings support further development and use of the behavioral tasks for assessing latency and control of saccades in PD.

  18. Straightforward and accurate technique for post-coupler stabilization in drift tube linac structures

    NASA Astrophysics Data System (ADS)

    Khalvati, Mohammad Reza; Ramberger, Suitbert

    2016-04-01

    The axial electric field of Alvarez drift tube linacs (DTLs) is known to be susceptible to variations due to static and dynamic effects like manufacturing tolerances and beam loading. Post-couplers are used to stabilize the accelerating fields of DTLs against tuning errors. Tilt sensitivity and its slope have been introduced as measures for the stability right from the invention of post-couplers but since then the actual stabilization has mostly been done by tedious iteration. In the present article, the local tilt-sensitivity slope TSn' is established as the principal measure for stabilization instead of tilt sensitivity or some visual slope, and its significance is developed on the basis of an equivalent-circuit diagram of the DTL. Experimental and 3D simulation results are used to analyze its behavior and to define a technique for stabilization that allows finding the best post-coupler settings with just four tilt-sensitivity measurements. CERN's Linac4 DTL Tank 2 and Tank 3 have been stabilized successfully using this technique. The final tilt-sensitivity error has been reduced from ±100 %/MHz down to ±3 %/MHz for Tank 2 and down to ±1 %/MHz for Tank 3. Finally, an accurate procedure for tuning the structure using slug tuners is discussed.

  19. Highly accurate photogrammetric measurements of the Planck reflectors

    NASA Astrophysics Data System (ADS)

    Amiri Parian, Jafar; Gruen, Armin; Cozzani, Alessandro

    2017-11-01

    The Planck mission of the European Space Agency (ESA) is designed to image the anisotropies of the Cosmic Background Radiation Field over the whole sky. To achieve this aim, sophisticated reflectors are used as part of the Planck telescope receiving system. The system consists of secondary and primary reflectors which are sections of two different ellipsoids of revolution with mean diameters of 1 and 1.6 meters. Deformations of the reflectors which influence the optical parameters and the gain of receiving signals are investigated in vacuum and at very low temperatures. For this investigation, among the various high accuracy measurement techniques, photogrammetry was selected. With respect to the photogrammetric measurements, special considerations had to be taken into account in design steps, measurement arrangement and data processing to achieve very high accuracies. The determinability of additional parameters of the camera under the given network configuration, datum definition, reliability and precision issues as well as workspace limits and propagating errors from different sources are considered. We have designed an optimal photogrammetric network by heuristic simulation for the flight model of the primary and the secondary reflectors with relative precisions better than 1:1000'000 and 1:400'000 to achieve the requested accuracies. A least squares best fit ellipsoid method was developed to determine the optical parameters of the reflectors. In this paper we will report about the procedures, the network design and the results of real measurements.

  20. Relationships of Behavioral Measures of Frontal Lobe Dysfunction with Underlying Electrophysiology in Cocaine-Dependent Patients

    PubMed Central

    Gjini, Klevest; Qazi, Aisha; Greenwald, Mark K.; Sandhu, Ravinder; Gooding, Diane C.; Boutros, Nash N.

    2013-01-01

    Background and Objectives Despite evidence that frontal lobe functioning is impaired in cocaine-dependent individuals, relationships between behavioral measures of frontal dysfunction and electrophysiological measures of inhibition in cocaine use have not been explored. Methods Using the Frontal System Behavior Scale (FrSBe), frontal dysfunction was assessed in a group of abstinent cocaine-dependent subjects (N=49) and healthy controls (N=32). Using transcranial magnetic stimulation (TMS) and evoked potential (EP)-based electrophysiological measures of inhibition, we assessed associations between these measures and FrSBe estimates of frontal dysfunction. Results Patients had significantly higher FrSBe scores for executive dysfunction, disinhibition and apathy than controls. Lower TMS-based resting motor thresholds (i.e., hyperexcitability) were significantly associated with higher Executive Dysfunction scores in the patients. Conclusions and Scientific Significance Relationships between FrSBe scores and TMS-based measures highlight neurophysiological aberrations underlying frontal lobe dysfunction in cocaine abusers. TMS and EP measures may be useful probes of the intermediary steps between frontal lobe dysfunction and addictive behavior. PMID:24724884

  1. Robust and accurate decoding of motoneuron behavior and prediction of the resulting force output.

    PubMed

    Thompson, Christopher K; Negro, Francesco; Johnson, Michael D; Holmes, Matthew R; McPherson, Laura Miller; Powers, Randall K; Farina, Dario; Heckman, Charles J

    2018-05-03

    The spinal alpha motoneuron is the only cell in the human CNS whose discharge can be routinely recorded in humans. We have reengineered motor unit collection and decomposition approaches, originally developed in humans, to measure the neural drive to muscle and estimate muscle force generation in the decerebrate cat model. Experimental, computational, and predictive approaches are used to demonstrate the validity of this approach across a wide range of modes to activate the motor pool. The utility of this approach is shown through the ability to track individual motor units across trials, allowing for better predictions of muscle force than the electromyography signal, and providing insights in to the stereotypical discharge characteristics in response to synaptic activation of the motor pool. This approach now allows for a direct link between the intracellular data of single motoneurons, the discharge properties of motoneuron populations, and muscle force generation in the same preparation. The discharge of a spinal alpha motoneuron and the resulting contraction of its muscle fibers represents the functional quantum of the motor system. Recent advances in the recording and decomposition of the electromyographic signal allows for the identification of several tens of concurrently active motor units. These detailed population data provide the potential to achieve deep insights into the synaptic organization of motor commands. Yet most of our understanding of the synaptic input to motoneurons is derived from intracellular recordings in animal preparations. Thus, it is necessary to extend the new electrode and decomposition methods to recording of motor unit populations in these same preparations. To achieve this goal, we use high-density electrode arrays and decomposition techniques, analogous to those developed for humans, to record and decompose the activity of tens of concurrently active motor units in a hindlimb muscle in the decerebrate cat. Our results showed

  2. Truth or consequences: the intertemporal consistency of adolescent self-report on the Youth Risk Behavior Survey.

    PubMed

    Rosenbaum, Janet E

    2009-06-01

    Surveys are the primary information source about adolescents' health risk behaviors, but adolescents may not report their behaviors accurately. Survey data are used for formulating adolescent health policy, and inaccurate data can cause mistakes in policy creation and evaluation. The author used test-retest data from the Youth Risk Behavior Survey (United States, 2000) to compare adolescents' responses to 72 questions about their risk behaviors at a 2-week interval. Each question was evaluated for prevalence change and 3 measures of unreliability: inconsistency (retraction and apparent initiation), agreement measured as tetrachoric correlation, and estimated error due to inconsistency assessed with a Bayesian method. Results showed that adolescents report their sex, drug, alcohol, and tobacco histories more consistently than other risk behaviors in a 2-week period, opposite their tendency over longer intervals. Compared with other Youth Risk Behavior Survey topics, most sex, drug, alcohol, and tobacco items had stable prevalence estimates, higher average agreement, and lower estimated measurement error. Adolescents reported their weight control behaviors more unreliably than other behaviors, particularly problematic because of the increased investment in adolescent obesity research and reliance on annual surveys for surveillance and policy evaluation. Most weight control items had unstable prevalence estimates, lower average agreement, and greater estimated measurement error than other topics.

  3. Improving Measures via Examining the Behavior of Distractors in Multiple-Choice Tests

    PubMed Central

    Sideridis, Georgios; Tsaousis, Ioannis; Al Harbi, Khaleel

    2017-01-01

    The purpose of the present article was to illustrate, using an example from a national assessment, the value from analyzing the behavior of distractors in measures that engage the multiple-choice format. A secondary purpose of the present article was to illustrate four remedial actions that can potentially improve the measurement of the construct(s) under study. Participants were 2,248 individuals who took a national examination of chemistry. The behavior of the distractors was analyzed by modeling their behavior within the Rasch model. Potentially informative distractors were (a) further modeled using the partial credit model, (b) split onto separate items and retested for model fit and parsimony, (c) combined to form a “super” item or testlet, and (d) reexamined after deleting low-ability individuals who likely guessed on those informative, albeit erroneous, distractors. Results indicated that all but the item split strategies were associated with better model fit compared with the original model. The best fitted model, however, involved modeling and crediting informative distractors via the partial credit model or eliminating the responses of low-ability individuals who likely guessed on informative distractors. The implications, advantages, and disadvantages of modeling informative distractors for measurement purposes are discussed. PMID:29795904

  4. Use of an inertial navigation system for accurate track recovery and coastal oceanographic measurements

    NASA Technical Reports Server (NTRS)

    Oliver, B. M.; Gower, J. F. R.

    1977-01-01

    A data acquisition system using a Litton LTN-51 inertial navigation unit (INU) was tested and used for aircraft track recovery and for location and tracking from the air of targets at sea. The characteristic position drift of the INU is compensated for by sighting landmarks of accurately known position at discrete time intervals using a visual sighting system in the transparent nose of the Beechcraft 18 aircraft used. For an aircraft altitude of about 300 m, theoretical and experimental tests indicate that calculated aircraft and/or target positions obtained from the interpolated INU drift curve will be accurate to within 10 m for landmarks spaced approximately every 15 minutes in time. For applications in coastal oceanography, such as surface current mapping by tracking artificial targets, the system allows a broad area to be covered without use of high altitude photography and its attendant needs for large targets and clear weather.

  5. Dimensionality of the Measure of Ingratiatory Behaviors in Organizational Settings (MIBOS) Scale.

    ERIC Educational Resources Information Center

    Kacmar, K. Michele; Valle, Matthew

    1997-01-01

    The dimensionality of the Measure of Ingratiatory Behaviors in Organizational Settings (MIBOS) (K. Kumar and M. Beyerlein, 1991) was studied with data from 203 state government employees. Results do not confirm the factor solution proposed by the measure's creators. Suggestions are offered to improve the psychometric properties of the MIBOS scale.…

  6. Measurement Properties of Indirect Assessment Methods for Functional Behavioral Assessment: A Review of Research

    ERIC Educational Resources Information Center

    Floyd, Randy G.; Phaneuf, Robin L.; Wilczynski, Susan M.

    2005-01-01

    Indirect assessment instruments used during functional behavioral assessment, such as rating scales, interviews, and self-report instruments, represent the least intrusive techniques for acquiring information about the function of problem behavior. This article provides criteria for examining the measurement properties of these instruments…

  7. The Construct of Adaptive Behavior: Its Conceptualization, Measurement, and Use in the Field of Intellectual Disability

    ERIC Educational Resources Information Center

    Tasse, Marc J.; Schalock, Robert L.; Balboni, Giulia; Bersani, Hank, Jr.; Borthwick-Duffy, Sharon A.; Spreat, Scott; Thissen, David; Widaman, Keith F.; Zhang, Dalun

    2012-01-01

    This article updates the current conceptualization, measurement, and use of the adaptive behavior construct. Major sections of the article address an understanding of the construct, the current approaches to its measurement, four assessment issues and challenges related to the use of adaptive behavior information for the diagnosis of intellectual…

  8. Appetitive traits from infancy to adolescence: Using behavioral and neural measures to investigate obesity risk

    PubMed Central

    Carnell, Susan; Benson, Leora; Pryor, Katherine; Driggin, Elissa

    2013-01-01

    We come into the world with enduring predispositions towards food, which interact with environmental factors to influence our eating behaviors and weight trajectories. But our fates are not sealed – by learning more about this process we can identify ways to intervene. To advance this goal this we need to be able to assess appetitive traits such as food cue responsiveness and satiety sensitivity at different developmental stages. Assessment methods might include behavioral measures (e.g. eating behavior tests, psychometric questionnaires), but also biomarkers such as brain responses to food cues measured using fMRI. Evidence from infants, children and adolescents suggests that these indices of appetite differ not only with body weight, but also with familial obesity risk as assessed by parent weight, which reflects both genetic and environmental influences, and may provide a useful predictor of obesity development. Behavioral and neural approaches have great potential to inform each other: examining eating behavior can help us identify meaningful appetitive endophenotypes whose neural bases can be probed, while increasing knowledge of the shared neurobiology underlying appetite, obesity, and related behaviors and disorders may ultimately lead to innovative generalized interventions. Another challenge will be to combine comprehensive behavioral and neural assessments of appetitive traits with measures of relevant genetic and environmental factors within long-term prospective studies. This approach may help to identify the biobehavioral precursors of obesity, and lay the foundations for targeted neurobehavioral interventions that can interrupt the pathway to excess weight. PMID:23458627

  9. Appearing smart: the impression management of intelligence, person perception accuracy, and behavior in social interaction.

    PubMed

    Murphy, Nora A

    2007-03-01

    Intelligence is an important trait that affects everyday social interaction. The present research utilized the ecological perspective of social perception to investigate the impression management of intelligence and strangers' evaluations of targets' intelligence levels. The ability to effectively portray an impression of intelligence to outside judges as well as interaction partners was appraised and the effect of impression management on the accurate judgment of intelligence was assessed. In addition, targets' behavior was studied in relation to impression management, perceived intelligence, and actual measured intelligence. Impression-managing targets appeared more intelligent to video judges but not to their interaction partner as compared to controls. The intelligence quotient (IQ) of impression-managing targets was more accurately judged than controls' IQ. Impression-managing targets displayed distinct nonverbal behavioral patterns that differed from controls. Looking while speaking was a key behavior: It significantly correlated with IQ, was successfully manipulated by impression-managing targets, and contributed to higher perceived intelligence ratings.

  10. Accurate Measurements of Spectral Reflectance in Picasso's Guernica Painting.

    PubMed

    de Luna, Javier Muñoz; Fernandez-Balbuena, Antonio Alvarez; Vázquez, Daniel; Melgosa, Manuel; Durán, Humberto; García, Jorge; Muro, Carmen

    2016-01-01

    The use of non-invasive spectral measurements to control the conservation status is a part of the preventive conservation of artworks which nowadays is becoming increasingly interesting. This paper describes how to use a spectral measuring device and an illumination system specifically designed for such a task in a very large dimension artwork painting (7.8 m wide × 3.5 m high). The system, controlled by a Cartesian robot, allows spectral measurements in a spectral range of 400-780 nm. The measured data array has a total of 2201 circular regions with 5.5 mm spot diameter placed on a square grid. Colorimetric calculations performed from these spectral measurements may be used to characterize color shifts related to reflectance changes in specific areas of the paint. A color shifting from the expected gray has been shown. © The Author(s) 2015.

  11. Necessary Conditions for Accurate, Transient Hot-Wire Measurements of the Apparent Thermal Conductivity of Nanofluids are Seldom Satisfied

    NASA Astrophysics Data System (ADS)

    Antoniadis, Konstantinos D.; Tertsinidou, Georgia J.; Assael, Marc J.; Wakeham, William A.

    2016-08-01

    The paper considers the conditions that are necessary to secure accurate measurement of the apparent thermal conductivity of two-phase systems comprising nanoscale particles of one material suspended in a fluid phase of a different material. It is shown that instruments operating according to the transient hot-wire technique can, indeed, produce excellent measurements when a finite element method (FEM) is employed to describe the instrument for the exact geometry of the hot wire. Furthermore, it is shown that an approximate analytic solution can be employed with equal success, over the time range of 0.1 s to 1 s, provided that (a) two wires are employed, so that end effects are canceled, (b) each wire is very thin, less than 30 \\upmu m diameter, so that the line source model and the corresponding corrections are valid, (c) low values of the temperature rise, less than 4 K, are employed in order to minimize the effect of convection on the heat transfer in the time of measurement of 1 s, and (d) insulated wires are employed for measurements in electrically conducting or polar liquids to avoid current leakage or other electrical distortions. According to these criteria, a transient hot-wire instrument has been designed, constructed, and employed for the measurement of the enhancement of the thermal conductivity of water when TiO2 or multi-wall carbon nanotubes (MWCNT) are added. These new results, together with a critical evaluation of other measurements, demonstrate the importance of proper implementation of the technique.

  12. Keep Your Scanners Peeled: Gaze Behavior as a Measure of Automation Trust During Highly Automated Driving.

    PubMed

    Hergeth, Sebastian; Lorenz, Lutz; Vilimek, Roman; Krems, Josef F

    2016-05-01

    The feasibility of measuring drivers' automation trust via gaze behavior during highly automated driving was assessed with eye tracking and validated with self-reported automation trust in a driving simulator study. Earlier research from other domains indicates that drivers' automation trust might be inferred from gaze behavior, such as monitoring frequency. The gaze behavior and self-reported automation trust of 35 participants attending to a visually demanding non-driving-related task (NDRT) during highly automated driving was evaluated. The relationship between dispositional, situational, and learned automation trust with gaze behavior was compared. Overall, there was a consistent relationship between drivers' automation trust and gaze behavior. Participants reporting higher automation trust tended to monitor the automation less frequently. Further analyses revealed that higher automation trust was associated with lower monitoring frequency of the automation during NDRTs, and an increase in trust over the experimental session was connected with a decrease in monitoring frequency. We suggest that (a) the current results indicate a negative relationship between drivers' self-reported automation trust and monitoring frequency, (b) gaze behavior provides a more direct measure of automation trust than other behavioral measures, and (c) with further refinement, drivers' automation trust during highly automated driving might be inferred from gaze behavior. Potential applications of this research include the estimation of drivers' automation trust and reliance during highly automated driving. © 2016, Human Factors and Ergonomics Society.

  13. Time-Accurate Numerical Simulations of Synthetic Jet Quiescent Air

    NASA Technical Reports Server (NTRS)

    Rupesh, K-A. B.; Ravi, B. R.; Mittal, R.; Raju, R.; Gallas, Q.; Cattafesta, L.

    2007-01-01

    The unsteady evolution of three-dimensional synthetic jet into quiescent air is studied by time-accurate numerical simulations using a second-order accurate mixed explicit-implicit fractional step scheme on Cartesian grids. Both two-dimensional and three-dimensional calculations of synthetic jet are carried out at a Reynolds number (based on average velocity during the discharge phase of the cycle V(sub j), and jet width d) of 750 and Stokes number of 17.02. The results obtained are assessed against PIV and hotwire measurements provided for the NASA LaRC workshop on CFD validation of synthetic jets.

  14. Fast and Accurate Circuit Design Automation through Hierarchical Model Switching.

    PubMed

    Huynh, Linh; Tagkopoulos, Ilias

    2015-08-21

    In computer-aided biological design, the trifecta of characterized part libraries, accurate models and optimal design parameters is crucial for producing reliable designs. As the number of parts and model complexity increase, however, it becomes exponentially more difficult for any optimization method to search the solution space, hence creating a trade-off that hampers efficient design. To address this issue, we present a hierarchical computer-aided design architecture that uses a two-step approach for biological design. First, a simple model of low computational complexity is used to predict circuit behavior and assess candidate circuit branches through branch-and-bound methods. Then, a complex, nonlinear circuit model is used for a fine-grained search of the reduced solution space, thus achieving more accurate results. Evaluation with a benchmark of 11 circuits and a library of 102 experimental designs with known characterization parameters demonstrates a speed-up of 3 orders of magnitude when compared to other design methods that provide optimality guarantees.

  15. Can variations in visual behavior measures be good predictors of driver sleepiness? A real driving test study.

    PubMed

    Wang, Yonggang; Xin, Mengyang; Bai, Han; Zhao, Yangdong

    2017-02-17

    The primary purpose of this study was to examine the association between variations in visual behavior measures and subjective sleepiness levels across age groups over time to determine a quantitative method of measuring drivers' sleepiness levels. A total of 128 volunteer drivers in 4 age groups were asked to finish 2-, 3-, and 4-h continuous driving tasks on expressways, during which the driver's fixation, saccade, and blink measures were recorded by an eye-tracking system and the subjective sleepiness level was measured through the Stanford Sleepiness Scale. Two-way repeated measures analysis of variance was then used to examine the change in visual behavior measures across age groups over time and compare the interactive effects of these 2 factors on the dependent visual measures. Drivers' visual behavior measures and subjective sleepiness levels vary significantly over time but not across age groups. A statistically significant interaction between age group and driving duration was found in drivers' pupil diameter, deviation of search angle, saccade amplitude, blink frequency, blink duration, and closure duration. Additionally, change in a driver's subjective sleepiness level is positively or negatively associated with variation in visual behavior measures, and such relationships can be expressed in regression models for different period of driving duration. Driving duration affects drivers' sleepiness significantly, so the amount of continuous driving time should be strictly controlled. Moreover, driving sleepiness can be quantified through the change rate of drivers' visual behavior measures to alert drivers of sleepiness risk and to encourage rest periods. These results provide insight into potential strategies for reducing and preventing traffic accidents and injuries.

  16. Accurately Mapping M31's Microlensing Population

    NASA Astrophysics Data System (ADS)

    Crotts, Arlin

    2004-07-01

    We propose to augment an existing microlensing survey of M31 with source identifications provided by a modest amount of ACS {and WFPC2 parallel} observations to yield an accurate measurement of the masses responsible for microlensing in M31, and presumably much of its dark matter. The main benefit of these data is the determination of the physical {or "einstein"} timescale of each microlensing event, rather than an effective {"FWHM"} timescale, allowing masses to be determined more than twice as accurately as without HST data. The einstein timescale is the ratio of the lensing cross-sectional radius and relative velocities. Velocities are known from kinematics, and the cross-section is directly proportional to the {unknown} lensing mass. We cannot easily measure these quantities without knowing the amplification, hence the baseline magnitude, which requires the resolution of HST to find the source star. This makes a crucial difference because M31 lens m ass determinations can be more accurate than those towards the Magellanic Clouds through our Galaxy's halo {for the same number of microlensing events} due to the better constrained geometry in the M31 microlensing situation. Furthermore, our larger survey, just completed, should yield at least 100 M31 microlensing events, more than any Magellanic survey. A small amount of ACS+WFPC2 imaging will deliver the potential of this large database {about 350 nights}. For the whole survey {and a delta-function mass distribution} the mass error should approach only about 15%, or about 6% error in slope for a power-law distribution. These results will better allow us to pinpoint the lens halo fraction, and the shape of the halo lens spatial distribution, and allow generalization/comparison of the nature of halo dark matter in spiral galaxies. In addition, we will be able to establish the baseline magnitude for about 50, 000 variable stars, as well as measure an unprecedentedly deta iled color-magnitude diagram and luminosity

  17. Is oral temperature an accurate measurement of deep body temperature? A systematic review.

    PubMed

    Mazerolle, Stephanie M; Ganio, Matthew S; Casa, Douglas J; Vingren, Jakob; Klau, Jennifer

    2011-01-01

    Oral temperature might not be a valid method to assess core body temperature. However, many clinicians, including athletic trainers, use it rather than criterion standard methods, such as rectal thermometry. To critically evaluate original research addressing the validity of using oral temperature as a measurement of core body temperature during periods of rest and changing core temperature. In July 2010, we searched the electronic databases PubMed, Scopus, Cumulative Index to Nursing and Allied Health Literature (CINAHL), SPORTDiscus, Academic Search Premier, and the Cochrane Library for the following concepts: core body temperature, oral, and thermometers. Controlled vocabulary was used, when available, as well as key words and variations of those key words. The search was limited to articles focusing on temperature readings and studies involving human participants. Original research was reviewed using the Physiotherapy Evidence Database (PEDro). Sixteen studies met the inclusion criteria and subsequently were evaluated by 2 independent reviewers. All 16 were included in the review because they met the minimal PEDro score of 4 points (of 10 possible points), with all but 2 scoring 5 points. A critical review of these studies indicated a disparity between oral and criterion standard temperature methods (eg, rectal and esophageal) specifically as the temperature increased. The difference was -0.50°C ± 0.31°C at rest and -0.58°C ± 0.75°C during a nonsteady state. Evidence suggests that, regardless of whether the assessment is recorded at rest or during periods of changing core temperature, oral temperature is an unsuitable diagnostic tool for determining body temperature because many measures demonstrated differences greater than the predetermined validity threshold of 0.27°C (0.5°F). In addition, the differences were greatest at the highest rectal temperatures. Oral temperature cannot accurately reflect core body temperature, probably because it is

  18. Development of an accurate portable recording peak-flow meter for the diagnosis of asthma.

    PubMed

    Hitchings, D J; Dickinson, S A; Miller, M R; Fairfax, A J

    1993-05-01

    This article describes the systematic design of an electronic recording peak expiratory flow (PEF) meter to provide accurate data for the diagnosis of occupational asthma. Traditional diagnosis of asthma relies on accurate data of PEF tests performed by the patients in their own homes and places of work. Unfortunately there are high error rates in data produced and recorded by the patient, most of these are transcription errors and some patients falsify their records. The PEF measurement itself is not effort independent, the data produced depending on the way in which the patient performs the test. Patients are taught how to perform the test giving maximal effort to the expiration being measured. If the measurement is performed incorrectly then errors will occur. Accurate data can be produced if an electronically recording PEF instrument is developed, thus freeing the patient from the task of recording the test data. It should also be capable of determining whether the PEF measurement has been correctly performed. A requirement specification for a recording PEF meter was produced. A commercially available electronic PEF meter was modified to provide the functions required for accurate serial recording of the measurements produced by the patients. This is now being used in three hospitals in the West Midlands for investigations into the diagnosis of occupational asthma. In investigating current methods of measuring PEF and other pulmonary quantities a greater understanding was obtained of the limitations of current methods of measurement, and quantities being measured.(ABSTRACT TRUNCATED AT 250 WORDS)

  19. High Order Schemes in Bats-R-US for Faster and More Accurate Predictions

    NASA Astrophysics Data System (ADS)

    Chen, Y.; Toth, G.; Gombosi, T. I.

    2014-12-01

    BATS-R-US is a widely used global magnetohydrodynamics model that originally employed second order accurate TVD schemes combined with block based Adaptive Mesh Refinement (AMR) to achieve high resolution in the regions of interest. In the last years we have implemented fifth order accurate finite difference schemes CWENO5 and MP5 for uniform Cartesian grids. Now the high order schemes have been extended to generalized coordinates, including spherical grids and also to the non-uniform AMR grids including dynamic regridding. We present numerical tests that verify the preservation of free-stream solution and high-order accuracy as well as robust oscillation-free behavior near discontinuities. We apply the new high order accurate schemes to both heliospheric and magnetospheric simulations and show that it is robust and can achieve the same accuracy as the second order scheme with much less computational resources. This is especially important for space weather prediction that requires faster than real time code execution.

  20. Measuring Protective Behavioral Strategies for Marijuana Use Among Young Adults.

    PubMed

    Pedersen, Eric R; Hummer, Justin F; Rinker, Dipali Venkataraman; Traylor, Zach K; Neighbors, Clayton

    2016-05-01

    Marijuana use can result in a variety of negative consequences, yet it remains popular among young adults and the general public at large. Combined with the growing empirical support for the benefits of medicinal marijuana as well as the steady increase in popular opinion regarding its legalization, it is of growing importance to identify strategies that may mitigate the harms related to marijuana use, reduce consumption levels, and limit resulting negative consequences among young adults who use marijuana. The purpose of this study was to develop and conduct initial psychometric analyses on a new scale, which we named the Protective Behavioral Strategies for Marijuana (PBSM) scale. A sample of undergraduate college students who reported past-6-month marijuana use (n = 210) responded to the initial pool of PBSM items and completed measures of marijuana use, consequences from marijuana use, alcohol use, and protective behavioral strategies for alcohol. Results from an iterative principal component analyses process yielded a single-factor structure with 39 items. The PBSM mean composite score negatively associated with marijuana use and consequences, with the strongest correlations evident for pastmonth users. The PBSM also significantly positively correlated with alcohol protective strategies. Protective behavioral strategies for marijuana appear to be a measurable construct that are related to marijuana frequency and consequences, and thus may be a useful component of intervention and prevention programs with young adults. More work testing the PBSM items with larger and more diverse samples of young adults is encouraged.

  1. How do men and women help? Validation of a multidimensional measure of prosocial behavior.

    PubMed

    Nielson, Matthew G; Padilla-Walker, Laura; Holmes, Erin K

    2017-04-01

    The current study sought to address gender differences in prosocial behavior by creating and validating a multidimensional measure of prosocial behavior that more fully captures the ways that men help others. The new measure is directed toward family, friend, and strangers, and has five factors: defending, emotional support, inclusion, physical helping, and sharing. In Study 1, CFA analyses performed on a sample of 463 emerging adults online (mean age 23.42) revealed good model fit and divergent validity for each of the five factors. Study 2 replicated the analyses on a sample of 453 urban adolescents in the Northwest (mean age 18.37). Results established that all factors had good model fit, construct validity, and convergent validity. The discussion focuses on implications of this measure for future prosocial research including an increased diversity in how people (particularly men) help others and developmental differences toward different targets of prosocial behavior. Copyright © 2017 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.

  2. Sky-radiance gradient measurements at narrow bands in the visible.

    PubMed

    Winter, E M; Metcalf, T W; Stotts, L B

    1995-07-01

    Accurate calibrated measurements of the radiance of the daytime sky were made in narrow bands in the visible portion of the spectrum. These measurements were made over several months and were tabulated in a sun-referenced coordinate system. The radiance as a function of wavelength at angles ranging from 5 to 90 deg was plotted. A best-fit inverse power-law fit shows inversely linear behavior of the radiance versus wavelength near the Sun (5 deg) and a slope approaching inverse fourth power far from the Sun (60 deg). This behavior fits a Mie-scattering interpretation near the Sun and a Rayleigh-scattering interpretation away from the Sun. The results are also compared with LOWTRAN models.

  3. Determination of accurate vertical atmospheric profiles of extinction and turbulence

    NASA Astrophysics Data System (ADS)

    Hammel, Steve; Campbell, James; Hallenborg, Eric

    2017-09-01

    Our ability to generate an accurate vertical profile characterizing the atmosphere from the surface to a point above the boundary layer top is quite rudimentary. The region from a land or sea surface to an altitude of 3000 meters is dynamic and particularly important to the performance of many active optical systems. Accurate and agile instruments are necessary to provide measurements in various conditions, and models are needed to provide the framework and predictive capability necessary for system design and optimization. We introduce some of the path characterization instruments and describe the first work to calibrate and validate them. Along with a verification of measurement accuracy, the tests must also establish each instruments performance envelope. Measurement of these profiles in the field is a problem, and we will present a discussion of recent field test activity to address this issue. The Comprehensive Atmospheric Boundary Layer Extinction/Turbulence Resolution Analysis eXperiment (CABLE/TRAX) was conducted late June 2017. There were two distinct objectives for the experiment: 1) a comparison test of various scintillometers and transmissometers on a homogeneous horizontal path; 2) a vertical profile experiment. In this paper we discuss only the vertical profiling effort, and we describe the instruments that generated data for vertical profiles of absorption, scattering, and turbulence. These three profiles are the core requirements for an accurate assessment of laser beam propagation.

  4. Estimating the state of a geophysical system with sparse observations: time delay methods to achieve accurate initial states for prediction

    DOE PAGES

    An, Zhe; Rey, Daniel; Ye, Jingxin; ...

    2017-01-16

    The problem of forecasting the behavior of a complex dynamical system through analysis of observational time-series data becomes difficult when the system expresses chaotic behavior and the measurements are sparse, in both space and/or time. Despite the fact that this situation is quite typical across many fields, including numerical weather prediction, the issue of whether the available observations are "sufficient" for generating successful forecasts is still not well understood. An analysis by Whartenby et al. (2013) found that in the context of the nonlinear shallow water equations on a β plane, standard nudging techniques require observing approximately 70 % of themore » full set of state variables. Here we examine the same system using a method introduced by Rey et al. (2014a), which generalizes standard nudging methods to utilize time delayed measurements. Here, we show that in certain circumstances, it provides a sizable reduction in the number of observations required to construct accurate estimates and high-quality predictions. In particular, we find that this estimate of 70 % can be reduced to about 33 % using time delays, and even further if Lagrangian drifter locations are also used as measurements.« less

  5. Estimating the state of a geophysical system with sparse observations: time delay methods to achieve accurate initial states for prediction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    An, Zhe; Rey, Daniel; Ye, Jingxin

    The problem of forecasting the behavior of a complex dynamical system through analysis of observational time-series data becomes difficult when the system expresses chaotic behavior and the measurements are sparse, in both space and/or time. Despite the fact that this situation is quite typical across many fields, including numerical weather prediction, the issue of whether the available observations are "sufficient" for generating successful forecasts is still not well understood. An analysis by Whartenby et al. (2013) found that in the context of the nonlinear shallow water equations on a β plane, standard nudging techniques require observing approximately 70 % of themore » full set of state variables. Here we examine the same system using a method introduced by Rey et al. (2014a), which generalizes standard nudging methods to utilize time delayed measurements. Here, we show that in certain circumstances, it provides a sizable reduction in the number of observations required to construct accurate estimates and high-quality predictions. In particular, we find that this estimate of 70 % can be reduced to about 33 % using time delays, and even further if Lagrangian drifter locations are also used as measurements.« less

  6. Rapid jetting status inspection and accurate droplet volume measurement for a piezo drop-on-demand inkjet print head using a scanning mirror for display applications

    NASA Astrophysics Data System (ADS)

    Shin, Dong-Youn; Kim, Minsung

    2017-02-01

    Despite the inherent fabrication simplicity of piezo drop-on-demand inkjet printing, the non-uniform deposition of colourants or electroluminescent organic materials leads to faulty display products, and hence, the importance of rapid jetting status inspection and accurate droplet volume measurement increases from a process perspective. In this work, various jetting status inspections and droplet volume measurement methods are reviewed by discussing their advantages and disadvantages, and then, the opportunities for the developed prototype with a scanning mirror are explored. This work demonstrates that jetting status inspection of 384 fictitious droplets can be performed within 17 s with maximum and minimum measurement accuracies of 0.2 ± 0.5 μ m for the fictitious droplets of 50 μ m in diameter and -1.2 ± 0.3 μ m for the fictitious droplets of 30 μ m in diameter, respectively. In addition to the new design of an inkjet monitoring instrument with a scanning mirror, two novel methods to accurately measure the droplet volume by amplifying a minute droplet volume difference and then converting to other physical properties are suggested and the droplet volume difference of ±0.3% is demonstrated to be discernible using numerical simulations, even with the low measurement accuracy of 1 μ m . When the fact is considered that the conventional vision-based method with a CCD camera requires the optical measurement accuracy less than 25 nm to measure the volume of an in-flight droplet in the nominal diameter of 50 μ m at the same volume measurement accuracy, the suggested method with the developed prototype offers a whole new opportunity to inkjet printing for display applications.

  7. Rapid jetting status inspection and accurate droplet volume measurement for a piezo drop-on-demand inkjet print head using a scanning mirror for display applications.

    PubMed

    Shin, Dong-Youn; Kim, Minsung

    2017-02-01

    Despite the inherent fabrication simplicity of piezo drop-on-demand inkjet printing, the non-uniform deposition of colourants or electroluminescent organic materials leads to faulty display products, and hence, the importance of rapid jetting status inspection and accurate droplet volume measurement increases from a process perspective. In this work, various jetting status inspections and droplet volume measurement methods are reviewed by discussing their advantages and disadvantages, and then, the opportunities for the developed prototype with a scanning mirror are explored. This work demonstrates that jetting status inspection of 384 fictitious droplets can be performed within 17 s with maximum and minimum measurement accuracies of 0.2 ± 0.5 μm for the fictitious droplets of 50 μm in diameter and -1.2 ± 0.3 μm for the fictitious droplets of 30 μm in diameter, respectively. In addition to the new design of an inkjet monitoring instrument with a scanning mirror, two novel methods to accurately measure the droplet volume by amplifying a minute droplet volume difference and then converting to other physical properties are suggested and the droplet volume difference of ±0.3% is demonstrated to be discernible using numerical simulations, even with the low measurement accuracy of 1 μm. When the fact is considered that the conventional vision-based method with a CCD camera requires the optical measurement accuracy less than 25 nm to measure the volume of an in-flight droplet in the nominal diameter of 50 μm at the same volume measurement accuracy, the suggested method with the developed prototype offers a whole new opportunity to inkjet printing for display applications.

  8. Beyond Behavioral Inhibition: A Computer Avatar Task Designed to Assess Behavioral Inhibition Extends to Harm Avoidance.

    PubMed

    Allen, Michael Todd; Jameson, Molly M; Myers, Catherine E

    2017-01-01

    Personality factors such as behavioral inhibition (BI), a temperamental tendency for avoidance in the face of unfamiliar situations, have been identified as risk factors for anxiety disorders. Personality factors are generally identified through self-report inventories. However, this tendency to avoid may affect the accuracy of these self-report inventories. Previously, a computer based task was developed in which the participant guides an on-screen "avatar" through a series of onscreen events; performance on the task could accurately predict participants' BI, measured by a standard paper and pencil questionnaire (Adult Measure of Behavioral Inhibition, or AMBI). Here, we sought to replicate this finding as well as compare performance on the avatar task to another measure related to BI, the harm avoidance (HA) scale of the Tridimensional Personality Questionnaire (TPQ). The TPQ includes HA scales as well as scales assessing reward dependence (RD), novelty seeking (NS) and persistence. One hundred and one undergraduates voluntarily completed the avatar task and the paper and pencil inventories in a counter-balanced order. Scores on the avatar task were strongly correlated with BI assessed via the AMBI questionnaire, which replicates prior findings. Females exhibited higher HA scores than males, but did not differ on scores on the avatar task. There was a strong positive relationship between scores on the avatar task and HA scores. One aspect of HA, fear of uncertainty was found to moderately mediate the relationship between AMBI scores and avatar scores. NS had a strong negative relationship with scores on the avatar task, but there was no significant relationship between RD and scores on the avatar task. These findings indicate the effectiveness of the avatar task as a behavioral alternative to self-report measures to assess avoidance. In addition, the use of computer based behavioral tasks are a viable alternative to paper and pencil self-report inventories

  9. Best methods for evaluating educational impact: a comparison of the efficacy of commonly used measures of library instruction.

    PubMed

    Schilling, Katherine; Applegate, Rachel

    2012-10-01

    Libraries are increasingly called upon to demonstrate student learning outcomes and the tangible benefits of library educational programs. This study reviewed and compared the efficacy of traditionally used measures for assessing library instruction, examining the benefits and drawbacks of assessment measures and exploring the extent to which knowledge, attitudes, and behaviors actually paralleled demonstrated skill levels. An overview of recent literature on the evaluation of information literacy education addressed these questions: (1) What evaluation measures are commonly used for evaluating library instruction? (2) What are the pros and cons of popular evaluation measures? (3) What are the relationships between measures of skills versus measures of attitudes and behavior? Research outcomes were used to identify relationships between measures of attitudes, behaviors, and skills, which are typically gathered via attitudinal surveys, written skills tests, or graded exercises. Results provide useful information about the efficacy of instructional evaluation methods, including showing significant disparities between attitudes, skills, and information usage behaviors. This information can be used by librarians to implement the most appropriate evaluation methods for measuring important variables that accurately demonstrate students' attitudes, behaviors, or skills.

  10. Accurate Time/Frequency Transfer Method Using Bi-Directional WDM Transmission

    NASA Technical Reports Server (NTRS)

    Imaoka, Atsushi; Kihara, Masami

    1996-01-01

    An accurate time transfer method is proposed using b-directional wavelength division multiplexing (WDM) signal transmission along a single optical fiber. This method will be used in digital telecommunication networks and yield a time synchronization accuracy of better than 1 ns for long transmission lines over several tens of kilometers. The method can accurately measure the difference in delay between two wavelength signals caused by the chromatic dispersion of the fiber in conventional simple bi-directional dual-wavelength frequency transfer methods. We describe the characteristics of this difference in delay and then show that the accuracy of the delay measurements can be obtained below 0.1 ns by transmitting 156 Mb/s times reference signals of 1.31 micrometer and 1.55 micrometers along a 50 km fiber using the proposed method. The sub-nanosecond delay measurement using the simple bi-directional dual-wavelength transmission along a 100 km fiber with a wavelength spacing of 1 nm in the 1.55 micrometer range is also shown.

  11. Questionnaire and laboratory measures of eating behavior: Associations with energy intake and BMI in a community sample of working adults

    PubMed Central

    French, Simone A; Mitchell, Nathan R; Wolfson, Julian; Finlayson, Graham; Blundell, John E; Jeffery, Robert W

    2013-01-01

    Purpose The present research compared a self-report measure of usual eating behaviors with two laboratory-based behavioral measures of food reward and food preference. Methods Eating behaviors were measured among 233 working adults. A self-report measure was the Three Factor Eating Questionnaire (TFEQ) Restraint, Disinhibition and Hunger subscales. Laboratory measures were the (RVF) and Explicit Liking (EL) and Implicit Wanting (IW) for high fat food. Outcome measures were body mass index (BMI), and energy intake measured using three 24-hour dietary recalls. Results Significant bivariate associations were observed between each of the eating behavior measures and energy intake, but only Disinhibition and Hunger were associated with BMI. Multiple regression results showed RVF and EL and IW predicted energy intake independent of the TFEQ scales but did not predict BMI. Conclusion Laboratory and self-report measures capture unique aspects of individual differences in eating behaviors that are associated with energy intake. PMID:24096082

  12. Developing Items to Measure Theory of Planned Behavior Constructs for Opioid Administration for Children: Pilot Testing.

    PubMed

    Vincent, Catherine; Riley, Barth B; Wilkie, Diana J

    2015-12-01

    The Theory of Planned Behavior (TpB) is useful to direct nursing research aimed at behavior change. As proposed in the TpB, individuals' attitudes, perceived norms, and perceived behavior control predict their intentions to perform a behavior and subsequently predict their actual performance of the behavior. Our purpose was to apply Fishbein and Ajzen's guidelines to begin development of a valid and reliable instrument for pediatric nurses' attitudes, perceived norms, perceived behavior control, and intentions to administer PRN opioid analgesics when hospitalized children self-report moderate to severe pain. Following Fishbein and Ajzen's directions, we were able to define the behavior of interest and specify the research population, formulate items for direct measures, elicit salient beliefs shared by our target population and formulate items for indirect measures, and prepare and test our questionnaire. For the pilot testing of internal consistency of measurement items, Cronbach alphas were between 0.60 and 0.90 for all constructs. Test-retest reliability correlations ranged from 0.63 to 0.90. Following Fishbein and Ajzen's guidelines was a feasible and organized approach for instrument development. In these early stages, we demonstrated good reliability for most subscales, showing promise for the instrument and its use in pain management research. Better understanding of the TpB constructs will facilitate the development of interventions targeted toward nurses' attitudes, perceived norms, and/or perceived behavior control to ultimately improve their pain behaviors toward reducing pain for vulnerable children. Copyright © 2015 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.

  13. EMR Gage Would Measure Coal Thickness Accurately

    NASA Technical Reports Server (NTRS)

    King, J. D.; Rollwitz, W. L.

    1982-01-01

    Laboratory tests indicate electron magnetic resonance (EMR) would be effective in measuring thickness of coal overlying rock substrate. In prototype dual-frequency EMR system, Sample is irradiated by two radio frequencies. Signals are mixed, producing sum and difference output frequencies that are detected by receiver. Magnetic field is varied to scan resonant spot through sample. In system designed for field use, electromagnet is U-shaped, so that sample can be adjacent to, rather than inside the probe. Same coil is used for transmitting and receiving.

  14. Is digital photography an accurate and precise method for measuring range of motion of the shoulder and elbow?

    PubMed

    Russo, Russell R; Burn, Matthew B; Ismaily, Sabir K; Gerrie, Brayden J; Han, Shuyang; Alexander, Jerry; Lenherr, Christopher; Noble, Philip C; Harris, Joshua D; McCulloch, Patrick C

    2018-03-01

    Accurate measurements of shoulder and elbow motion are required for the management of musculoskeletal pathology. The purpose of this investigation was to compare three techniques for measuring motion. The authors hypothesized that digital photography would be equivalent in accuracy and show higher precision compared to the other two techniques. Using infrared motion capture analysis as the reference standard, shoulder flexion/abduction/internal rotation/external rotation and elbow flexion/extension were measured using visual estimation, goniometry, and digital photography on 10 fresh frozen cadavers. These measurements were performed by three physical therapists and three orthopaedic surgeons. Accuracy was defined by the difference from the reference standard (motion capture analysis), while precision was defined by the proportion of measurements within the authors' definition of clinical significance (10° for all motions except for elbow extension where 5° was used). Analysis of variance (ANOVA), t-tests, and chi-squared tests were used. Although statistically significant differences were found in measurement accuracy between the three techniques, none of these differences met the authors' definition of clinical significance. Precision of the measurements was significantly higher for both digital photography (shoulder abduction [93% vs. 74%, p < 0.001], shoulder internal rotation [97% vs. 83%, p = 0.001], and elbow flexion [93% vs. 65%, p < 0.001]) and goniometry (shoulder abduction [92% vs. 74%, p < 0.001] and shoulder internal rotation [94% vs. 83%, p = 0.008]) than visual estimation. Digital photography was more precise than goniometry for measurements of elbow flexion only [93% vs. 76%, p < 0.001]. There was no clinically significant difference in measurement accuracy between the three techniques for shoulder and elbow motion. Digital photography showed higher measurement precision compared to visual estimation for shoulder abduction, shoulder

  15. Muscle function during brief maximal exercise: accurate measurements on a friction-loaded cycle ergometer.

    PubMed

    Arsac, L M; Belli, A; Lacour, J R

    1996-01-01

    A friction loaded cycle ergometer was instrumented with a strain gauge and an incremental encoder to obtain accurate measurement of human mechanical work output during the acceleration phase of a cycling sprint. This device was used to characterise muscle function in a group of 15 well-trained male subjects, asked to perform six short maximal sprints on the cycle against a constant friction load. Friction loads were successively set at 0.25, 0.35, 0.45, 0.55, 0.65 and 0.75 N.kg-1 body mass. Since the sprints were performed from a standing start, and since the acceleration was not restricted, the greatest attention was paid to the measurement of the acceleration balancing load due to flywheel inertia. Instantaneous pedalling velocity (v) and power output (P) were calculated each 5 ms and then averaged over each downstroke period so that each pedal downstroke provided a combination of v, force and P. Since an 8-s acceleration phase was composed of about 21 to 34 pedal downstrokes, this many v-P combinations were obtained amounting to 137-180 v-P combinations for all six friction loads in one individual, over the widest functional range of pedalling velocities (17-214 rpm). Thus, the individual's muscle function was characterised by the v-P relationships obtained during the six acceleration phases of the six sprints. An important finding of the present study was a strong linear relationship between individual optimal velocity (vopt) and individual maximal power output (Pmax) (n = 15, r = 0.95, P < 0.001) which has never been observed before. Since vopt has been demonstrated to be related to human fibre type composition both vopt, Pmax and their inter-relationship could represent a major feature in characterising muscle function in maximal unrestricted exercise. It is suggested that the present method is well suited to such analyses.

  16. Measurement artifacts in the assessment of counterproductive work behavior and organizational citizenship behavior: do we know what we think we know?

    PubMed

    Spector, Paul E; Bauer, Jeremy A; Fox, Suzy

    2010-07-01

    An experiment investigated whether measurement features affected observed relationships between counterproductive work behavior (CWB) and organizational citizenship behavior (OCB) and their relationships with other variables. As expected, correlations between CWB and OCB were significantly higher with ratings of agreement rather than frequency of behavior, when OCB scale content overlapped with CWB than when it did not, and with supervisor rather than self-ratings. Relationships with job satisfaction and job stressors were inconsistent across conditions. We concluded that CWB and OCB are likely unrelated and not necessarily oppositely related to other variables. Researchers should avoid overlapping content in CWB and OCB scales and should use frequency formats to assess how often individuals engage in each form of behavior.

  17. BIOACCESSIBILITY TESTS ACCURATELY ESTIMATE BIOAVAILABILITY OF LEAD TO QUAIL

    EPA Science Inventory

    Hazards of soil-borne Pb to wild birds may be more accurately quantified if the bioavailability of that Pb is known. To better understand the bioavailability of Pb to birds, we measured blood Pb concentrations in Japanese quail (Coturnix japonica) fed diets containing Pb-contami...

  18. Validation of a Measure of College Students' Intoxicated Behaviors: Associations with Alcohol Outcome Expectancies, Drinking Motives, and Personality

    ERIC Educational Resources Information Center

    Westmaas, Johann; Moeller, Scott; Woicik, Patricia Butler

    2007-01-01

    Objective: The authors aimed to develop a measure of college students' intoxicated behaviors and to validate the measure using scales assessing alcohol outcome expectancies, motives for drinking, and personality traits. Participants and Method Summary: The authors administered these measures and an inventory describing 50 intoxicated behaviors to…

  19. Recognition and Management of Behavioral Disturbances in Dementia

    PubMed Central

    Desai, Abhilash K.; Grossberg, George T.

    2001-01-01

    Behavioral disturbances are seen in most patients with dementia at some point in their course. They cause immense patient suffering and are responsible for caregiver stress, institutionalization, and hospitalization. Identification of predisposing and precipitating factors is very important. The approach to the management of behavioral disturbances in dementia patients should be structured and thorough. Ensuring the safety of the patient and others should be paramount. Addressing the causes of behavioral disturbances such as comorbid medical illnesses, polypharmacy, pain, personal need, environmental factors, etc. is critical to a successful outcome. Many behavioral disturbances such as wandering and hoarding are not amenable to pharmacotherapy. Nonpharmacologic interventions are the mainstay of managing behavioral disturbances. Success of pharmacologic interventions will depend on accurate identification of specific syndromes, e.g., depression-anxiety and psychosis and severity of symptoms. Response to pharmacologic interventions is usually modest and may be associated with significant symptom resolution. Many behavioral disturbances can be prevented by avoiding inappropriate medications and educating patient, family, caregivers, and health care providers. Hospitalization can be avoided and institutionalization delayed by early recognition and treatment of behavioral disturbances. Leadership from physicians to implement preventive measures is recommended. Research to clarify the biological underpinnings of behavioral disturbances and to address cost-effectiveness of currently identified interventions is needed. PMID:15014607

  20. Determining site index accurately in even-aged stands

    Treesearch

    Gayne G. Erdmann; Ralph M., Jr. Peterson

    1992-01-01

    Good site index estimates are necessary for intensive forest management. To get tree age used in determining site index, increment cores are commonly used. The diffuse-porous rings of northern hardwoods, though, are difficult to count in cores, so many site index estimates are imprecise. Also, measuring the height of standing trees is more difficult and less accurate...

  1. Transmission Electron Microscope Measures Lattice Parameters

    NASA Technical Reports Server (NTRS)

    Pike, William T.

    1996-01-01

    Convergent-beam microdiffraction (CBM) in thermionic-emission transmission electron microscope (TEM) is technique for measuring lattice parameters of nanometer-sized specimens of crystalline materials. Lattice parameters determined by use of CBM accurate to within few parts in thousand. Technique developed especially for use in quantifying lattice parameters, and thus strains, in epitaxial mismatched-crystal-lattice multilayer structures in multiple-quantum-well and other advanced semiconductor electronic devices. Ability to determine strains in indivdual layers contributes to understanding of novel electronic behaviors of devices.

  2. Accurate Laboratory Measurements of Vibration-Rotation Transitions of 36ArH^+ and 38ArH+

    NASA Astrophysics Data System (ADS)

    Cueto, Maite; Cernicharo, Jose; Herrero, Victor Jose; Tanarro, Isabel; Domenech, Jose Luis

    2014-06-01

    The protonated Ar ion 36ArH^+ has recently been identified in space, in the Crab Nebula, from Herschel spectra. Its R(0) and R(1) transitions lie at 617.5 and 1234.6 GHz, respectively, where atmospheric transmission is rather poor, even for a site as good as that of ALMA. As an alternative, especially after the end of the Herschel mission, rovibrational transitions of ArH^+ could be observed in absorption against bright background sources such as the galactic center, or other objects. We report on accurate laboratory wavenumber measurements of 19 lines of the v=1-0 band of 36ArH^+ and 38ArH^+, using a hollow cathode discharge cell, a difference frequency laser spectrometer and Ar with natural isotopic composition. Of those lines, only eight had been reported before and with much less accuracy. The data have also been used in a Dunham-type global fit of all published laboratory data (IR and sub-mm) of all isotopologues. Barlow et al., Science, 342, 1343 (2013) R.R. Filgueira and C.E. Blom, J. Mol. Spectrosc., 127, 279 (1988) M. Cueto et al, Astrophys. J. Lett, 783, L5 (2014)

  3. Method for accurate growth of vertical-cavity surface-emitting lasers

    DOEpatents

    Chalmers, Scott A.; Killeen, Kevin P.; Lear, Kevin L.

    1995-01-01

    We report a method for accurate growth of vertical-cavity surface-emitting lasers (VCSELs). The method uses a single reflectivity spectrum measurement to determine the structure of the partially completed VCSEL at a critical point of growth. This information, along with the extracted growth rates, allows imprecisions in growth parameters to be compensated for during growth of the remaining structure, which can then be completed with very accurate critical dimensions. Using this method, we can now routinely grow lasing VCSELs with Fabry-Perot cavity resonance wavelengths controlled to within 0.5%.

  4. Method for accurate growth of vertical-cavity surface-emitting lasers

    DOEpatents

    Chalmers, S.A.; Killeen, K.P.; Lear, K.L.

    1995-03-14

    The authors report a method for accurate growth of vertical-cavity surface-emitting lasers (VCSELs). The method uses a single reflectivity spectrum measurement to determine the structure of the partially completed VCSEL at a critical point of growth. This information, along with the extracted growth rates, allows imprecisions in growth parameters to be compensated for during growth of the remaining structure, which can then be completed with very accurate critical dimensions. Using this method, they can now routinely grow lasing VCSELs with Fabry-Perot cavity resonance wavelengths controlled to within 0.5%. 4 figs.

  5. Accurate Rapid Lifetime Determination on Time-Gated FLIM Microscopy with Optical Sectioning

    PubMed Central

    Silva, Susana F.; Domingues, José Paulo

    2018-01-01

    Time-gated fluorescence lifetime imaging microscopy (FLIM) is a powerful technique to assess the biochemistry of cells and tissues. When applied to living thick samples, it is hampered by the lack of optical sectioning and the need of acquiring many images for an accurate measurement of fluorescence lifetimes. Here, we report on the use of processing techniques to overcome these limitations, minimizing the acquisition time, while providing optical sectioning. We evaluated the application of the HiLo and the rapid lifetime determination (RLD) techniques for accurate measurement of fluorescence lifetimes with optical sectioning. HiLo provides optical sectioning by combining the high-frequency content from a standard image, obtained with uniform illumination, with the low-frequency content of a second image, acquired using structured illumination. Our results show that HiLo produces optical sectioning on thick samples without degrading the accuracy of the measured lifetimes. We also show that instrument response function (IRF) deconvolution can be applied with the RLD technique on HiLo images, improving greatly the accuracy of the measured lifetimes. These results open the possibility of using the RLD technique with pulsed diode laser sources to determine accurately fluorescence lifetimes in the subnanosecond range on thick multilayer samples, providing that offline processing is allowed. PMID:29599938

  6. Accurate Rapid Lifetime Determination on Time-Gated FLIM Microscopy with Optical Sectioning.

    PubMed

    Silva, Susana F; Domingues, José Paulo; Morgado, António Miguel

    2018-01-01

    Time-gated fluorescence lifetime imaging microscopy (FLIM) is a powerful technique to assess the biochemistry of cells and tissues. When applied to living thick samples, it is hampered by the lack of optical sectioning and the need of acquiring many images for an accurate measurement of fluorescence lifetimes. Here, we report on the use of processing techniques to overcome these limitations, minimizing the acquisition time, while providing optical sectioning. We evaluated the application of the HiLo and the rapid lifetime determination (RLD) techniques for accurate measurement of fluorescence lifetimes with optical sectioning. HiLo provides optical sectioning by combining the high-frequency content from a standard image, obtained with uniform illumination, with the low-frequency content of a second image, acquired using structured illumination. Our results show that HiLo produces optical sectioning on thick samples without degrading the accuracy of the measured lifetimes. We also show that instrument response function (IRF) deconvolution can be applied with the RLD technique on HiLo images, improving greatly the accuracy of the measured lifetimes. These results open the possibility of using the RLD technique with pulsed diode laser sources to determine accurately fluorescence lifetimes in the subnanosecond range on thick multilayer samples, providing that offline processing is allowed.

  7. Measurement Invariance of an Instrument Assessing Sustainability of School-Based Universal Behavior Practices

    ERIC Educational Resources Information Center

    Mercer, Sterett H.; McIntosh, Kent; Strickland-Cohen, M. Kathleen; Horner, Robert H.

    2014-01-01

    Objective: The purpose of the study was to examine the extent to which the School-wide Universal Behavior Sustainability Index: School Teams (SUBSIST; McIntosh, Doolittle, Vincent, Horner, & Ervin, 2009), a measure of school and district contextual factors that promote the sustainability of school practices, demonstrated measurement invariance…

  8. Measurement Invariance of an Instrument Assessing Sustainability of School-Based Universal Behavior Practices

    ERIC Educational Resources Information Center

    Mercer, Sterett H.; McIntosh, Kent; Strickland-Cohen, M. Kathleen; Horner, Robert H.

    2014-01-01

    The purpose of the study was to examine the extent to which the School-Wide Universal Behavior Sustainability Index: School Teams (SUBSIST; McIntosh, Doolittle, Vincent, Horner, & Ervin, 2009), a measure of school and district contextual factors that promote the sustainability of school practices, demonstrated measurement invariance across…

  9. Phase rainbow refractometry for accurate droplet variation characterization.

    PubMed

    Wu, Yingchun; Promvongsa, Jantarat; Saengkaew, Sawitree; Wu, Xuecheng; Chen, Jia; Gréhan, Gérard

    2016-10-15

    We developed a one-dimensional phase rainbow refractometer for the accurate trans-dimensional measurements of droplet size on the micrometer scale as well as the tiny droplet diameter variations at the nanoscale. The dependence of the phase shift of the rainbow ripple structures on the droplet variations is revealed. The phase-shifting rainbow image is recorded by a telecentric one-dimensional rainbow imaging system. Experiments on the evaporating monodispersed droplet stream show that the phase rainbow refractometer can measure the tiny droplet diameter changes down to tens of nanometers. This one-dimensional phase rainbow refractometer is capable of measuring the droplet refractive index and diameter, as well as variations.

  10. Validity and reliability of the abdominal test and evaluation systems tool (ABTEST) to accurately measure abdominal force.

    PubMed

    Glenn, Jordan M; Galey, Madeline; Edwards, Abigail; Rickert, Bradley; Washington, Tyrone A

    2015-07-01

    Ability to generate force from the core musculature is a critical factor for sports and general activities with insufficiencies predisposing individuals to injury. This study evaluated isometric force production as a valid and reliable method of assessing abdominal force using the abdominal test and evaluation systems tool (ABTEST). Secondary analysis estimated 1-repetition maximum on commercially available abdominal machine compared to maximum force and average power on ABTEST system. This study utilized test-retest reliability and comparative analysis for validity. Reliability was measured using test-retest design on ABTEST. Validity was measured via comparison to estimated 1-repetition maximum on a commercially available abdominal device. Participants applied isometric, abdominal force against a transducer and muscular activation was evaluated measuring normalized electromyographic activity at the rectus-abdominus, rectus-femoris, and erector-spinae. Test, re-test force production on ABTEST was significantly correlated (r=0.84; p<0.001). Mean electromyographic activity for the rectus-abdominus (72.93% and 75.66%), rectus-femoris (6.59% and 6.51%), and erector-spinae (6.82% and 5.48%) were observed for trial-1 and trial-2, respectively. Significant correlations for the estimated 1-repetition maximum were found for average power (r=0.70, p=0.002) and maximum force (r=0.72, p<0.001). Data indicate the ABTEST can accurately measure rectus-abdominus force isolated from hip-flexor involvement. Negligible activation of erector-spinae substantiates little subjective effort among participants in the lower back. Results suggest ABTEST is a valid and reliable method of evaluating abdominal force. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  11. Measuring Protective Behavioral Strategies for Marijuana Use Among Young Adults

    PubMed Central

    Pedersen, Eric R.; Hummer, Justin F.; Rinker, Dipali Venkataraman; Traylor, Zach K.; Neighbors, Clayton

    2016-01-01

    Objective: Marijuana use can result in a variety of negative consequences, yet it remains popular among young adults and the general public at large. Combined with the growing empirical support for the benefits of medicinal marijuana as well as the steady increase in popular opinion regarding its legalization, it is of growing importance to identify strategies that may mitigate the harms related to marijuana use, reduce consumption levels, and limit resulting negative consequences among young adults who use marijuana. The purpose of this study was to develop and conduct initial psychometric analyses on a new scale, which we named the Protective Behavioral Strategies for Marijuana (PBSM) scale. Method: A sample of undergraduate college students who reported past-6-month marijuana use (n = 210) responded to the initial pool of PBSM items and completed measures of marijuana use, consequences from marijuana use, alcohol use, and protective behavioral strategies for alcohol. Results: Results from an iterative principal component analyses process yielded a single-factor structure with 39 items. The PBSM mean composite score negatively associated with marijuana use and consequences, with the strongest correlations evident for past-month users. The PBSM also significantly positively correlated with alcohol protective strategies. Conclusions: Protective behavioral strategies for marijuana appear to be a measurable construct that are related to marijuana frequency and consequences, and thus may be a useful component of intervention and prevention programs with young adults. More work testing the PBSM items with larger and more diverse samples of young adults is encouraged. PMID:27172576

  12. A Modified ELISA Accurately Measures Secretion of High Molecular Weight Hyaluronan (HA) by Graves' Disease Orbital Cells

    PubMed Central

    Krieger, Christine C.

    2014-01-01

    Excess production of hyaluronan (hyaluronic acid [HA]) in the retro-orbital space is a major component of Graves' ophthalmopathy, and regulation of HA production by orbital cells is a major research area. In most previous studies, HA was measured by ELISAs that used HA-binding proteins for detection and rooster comb HA as standards. We show that the binding efficiency of HA-binding protein in the ELISA is a function of HA polymer size. Using gel electrophoresis, we show that HA secreted from orbital cells is primarily comprised of polymers more than 500 000. We modified a commercially available ELISA by using 1 million molecular weight HA as standard to accurately measure HA of this size. We demonstrated that IL-1β-stimulated HA secretion is at least 2-fold greater than previously reported, and activation of the TSH receptor by an activating antibody M22 from a patient with Graves' disease led to more than 3-fold increase in HA production in both fibroblasts/preadipocytes and adipocytes. These effects were not consistently detected with the commercial ELISA using rooster comb HA as standard and suggest that fibroblasts/preadipocytes may play a more prominent role in HA remodeling in Graves' ophthalmopathy than previously appreciated. PMID:24302624

  13. Highly accurate nephelometric titrimetry.

    PubMed

    Zhan, Xiancheng; Li, Chengrong; Li, Zhiyi; Yang, Xiucen; Zhong, Shuguang; Yi, Tao

    2004-02-01

    A method that accurately indicates the end-point of precipitation reactions by the measurement of the relative intensity of the scattered light in the titrate is presented. A new nephelometric titrator with an internal nephelometric sensor has been devised. The work of the titrator including the sensor and change in the turbidity of the titrate and intensity of the scattered light are described. The accuracy of the nephelometric titrimetry is discussed theoretically. The titration of NaCl with AgNO(3) serves as a model. A relative error as well as deviation is within 0.2% under the experimental conditions. The applicability of the titrimetry in pharmaceutical analyses, for example, phenytoin sodium and procaine hydrochloride, is generally illustrated. Copyright 2004 Wiley-Liss, Inc. and the American Pharmacists Association

  14. Simple Learned Weighted Sums of Inferior Temporal Neuronal Firing Rates Accurately Predict Human Core Object Recognition Performance

    PubMed Central

    Hong, Ha; Solomon, Ethan A.; DiCarlo, James J.

    2015-01-01

    database of images for evaluating object recognition performance. We used multielectrode arrays to characterize hundreds of neurons in the visual ventral stream of nonhuman primates and measured the object recognition performance of >100 human observers. Remarkably, we found that simple learned weighted sums of firing rates of neurons in monkey inferior temporal (IT) cortex accurately predicted human performance. Although previous work led us to expect that IT would outperform V4, we were surprised by the quantitative precision with which simple IT-based linking hypotheses accounted for human behavior. PMID:26424887

  15. Simple Learned Weighted Sums of Inferior Temporal Neuronal Firing Rates Accurately Predict Human Core Object Recognition Performance.

    PubMed

    Majaj, Najib J; Hong, Ha; Solomon, Ethan A; DiCarlo, James J

    2015-09-30

    database of images for evaluating object recognition performance. We used multielectrode arrays to characterize hundreds of neurons in the visual ventral stream of nonhuman primates and measured the object recognition performance of >100 human observers. Remarkably, we found that simple learned weighted sums of firing rates of neurons in monkey inferior temporal (IT) cortex accurately predicted human performance. Although previous work led us to expect that IT would outperform V4, we were surprised by the quantitative precision with which simple IT-based linking hypotheses accounted for human behavior. Copyright © 2015 the authors 0270-6474/15/3513402-17$15.00/0.

  16. Exploring the Use of Sensors to Measure Behavioral Interactions: An Experimental Evaluation of Using Hand Trajectories

    PubMed Central

    Bergmann, Jeroen H. M.; Langdon, Patrick M.; Mayagoitia, Ruth E.; Howard, Newton

    2014-01-01

    Humans appear to be sensitive to relative small changes in their surroundings. These changes are often initially perceived as irrelevant, but they can cause significant changes in behavior. However, how exactly people’s behavior changes is often hard to quantify. A reliable and valid tool is needed in order to address such a question, ideally measuring an important point of interaction, such as the hand. Wearable-body-sensor systems can be used to obtain valuable, behavioral information. These systems are particularly useful for assessing functional interactions that occur between the endpoints of the upper limbs and our surroundings. A new method is explored that consists of computing hand position using a wearable sensor system and validating it against a gold standard reference measurement (optical tracking device). Initial outcomes related well to the gold standard measurements (r = 0.81) showing an acceptable average root mean square error of 0.09 meters. Subsequently, the use of this approach was further investigated by measuring differences in motor behavior, in response to a changing environment. Three subjects were asked to perform a water pouring task with three slightly different containers. Wavelet analysis was introduced to assess how motor consistency was affected by these small environmental changes. Results showed that the behavioral motor adjustments to a variable environment could be assessed by applying wavelet coherence techniques. Applying these procedures in everyday life, combined with correct research methodologies, can assist in quantifying how environmental changes can cause alterations in our motor behavior. PMID:24516583

  17. A mind you can count on: validating breath counting as a behavioral measure of mindfulness.

    PubMed

    Levinson, Daniel B; Stoll, Eli L; Kindy, Sonam D; Merry, Hillary L; Davidson, Richard J

    2014-01-01

    Mindfulness practice of present moment awareness promises many benefits, but has eluded rigorous behavioral measurement. To date, research has relied on self-reported mindfulness or heterogeneous mindfulness trainings to infer skillful mindfulness practice and its effects. In four independent studies with over 400 total participants, we present the first construct validation of a behavioral measure of mindfulness, breath counting. We found it was reliable, correlated with self-reported mindfulness, differentiated long-term meditators from age-matched controls, and was distinct from sustained attention and working memory measures. In addition, we employed breath counting to test the nomological network of mindfulness. As theorized, we found skill in breath counting associated with more meta-awareness, less mind wandering, better mood, and greater non-attachment (i.e., less attentional capture by distractors formerly paired with reward). We also found in a randomized online training study that 4 weeks of breath counting training improved mindfulness and decreased mind wandering relative to working memory training and no training controls. Together, these findings provide the first evidence for breath counting as a behavioral measure of mindfulness.

  18. Intensity of play behavior as a potential measure of welfare: A novel method for quantifying the integrated intensity of behavior in African elephants.

    PubMed

    Vicino, Greg A; Marcacci, Emily S

    2015-01-01

    To the authors' knowledge there is currently no discrete index to measure the integrated intensity of a play bout in mammals, despite the potential for using intensity and duration of play bouts as a measure of physical activity and welfare. This study was developed to test an equation that quantified the intensity and duration of play bouts in a particularly gregarious mammal, African elephants (Loxodonta africana) housed at the San Diego Zoo Safari Park in Escondido, CA. To quantify these behaviors, we created a scale of intensity and a subsequent equation that produces an index value, giving each unique bout a score. A compilation of these scores provides a range of intensity of play behavior that is a representative value for that particular herd at that point in time, and thus a database to which later bouts can be compared. It can be argued that play behavior is an indicator of positive welfare, and if quantifiable, it is our belief that it can be used as an additional measure of positive welfare in zoo housed animals. Here we present the methods and technique used to calculate a standardized Integrated Play Index (IPI) that has potential for use in other socially living species that are known to exhibit play behavior. © 2015 Wiley Periodicals, Inc.

  19. Movement, resting, and attack behaviors of wild pumas are revealed by tri-axial accelerometer measurements.

    PubMed

    Wang, Yiwei; Nickel, Barry; Rutishauser, Matthew; Bryce, Caleb M; Williams, Terrie M; Elkaim, Gabriel; Wilmers, Christopher C

    2015-01-01

    Accelerometers are useful tools for biologists seeking to gain a deeper understanding of the daily behavior of cryptic species. We describe how we used GPS and tri-axial accelerometer (sampling at 64 Hz) collars to monitor behaviors of free-ranging pumas (Puma concolor), which are difficult or impossible to observe in the wild. We attached collars to twelve pumas in the Santa Cruz Mountains, CA from 2010-2012. By implementing Random Forest models, we classified behaviors in wild pumas based on training data from observations and measurements of captive puma behavior. We applied these models to accelerometer data collected from wild pumas and identified mobile and non-mobile behaviors in captive animals with an accuracy rate greater than 96%. Accuracy remained above 95% even after downsampling our accelerometer data to 16 Hz. We were further able to predict low-acceleration movement behavior (e.g. walking) and high-acceleration movement behavior (e.g. running) with 93.8% and 92% accuracy, respectively. We had difficulty predicting non-movement behaviors such as feeding and grooming due to the small size of our training dataset. Lastly, we used model-predicted and field-verified predation events to quantify acceleration characteristics of puma attacks on large prey. These results demonstrate that accelerometers are useful tools for classifying the behaviors of cryptic medium and large-sized terrestrial mammals in their natural habitats and can help scientists gain deeper insight into their fine-scale behavioral patterns. We also show how accelerometer measurements can provide novel insights on the energetics and predation behavior of wild animals. Lastly we discuss the conservation implications of identifying these behavioral patterns in free-ranging species as natural and anthropogenic landscape features influence animal energy allocation and habitat use.

  20. Effects of pretesting implicit self-determined motivation on behavioral engagement: evidence for the mere measurement effect at the implicit level.

    PubMed

    Keatley, David A; Clarke, David D; Ferguson, Eamonn; Hagger, Martin S

    2014-01-01

    Research into individuals' intended behavior and performance has traditionally adopted explicitly measured, self-report constructs, and outcomes. More recently, research has shown that completing explicit self-report measures of constructs may effect subsequent behavior, termed the "mere measurement" effect. The aim of the present experiment was to investigate whether implicit measures of motivation showed a similar mere measurement effect on subsequent behavior. It may be the case that measuring the implicit systems affects subsequent implicit interventions (e.g., priming), observable on subsequent behavior. Priming manipulations were also given to participants in order to investigate the interaction between measurement and priming of motivation. Initially, a 2 [implicit association test (IAT: present vs. absent) ×2 (Prime: autonomous vs. absent) and a 2 (IAT: present vs. absent) × 2 (Prime: controlled vs. absent)] between participants designs were conducted, these were them combined into a 2 (IAT: present vs. absent) ×3 (Prime: autonomous vs. controlled vs. absent) between participants design, with attempts at a novel task taken as the outcome measure. Implicit measure completion significantly decreased behavioral engagement. Priming autonomous motivation significantly facilitated, and controlled motivation significantly inhibited performance. Finally, there was a significant implicit measurement × priming interaction, such that priming autonomous motivation only improved performance in the absence of the implicit measure. Overall, this research provides an insight into the effects of implicit measurement and priming of motivation and the combined effect of completing both tasks on behavior.

  1. Conservation caring: measuring the influence of zoo visitors' connection to wildlife on pro-conservation behaviors.

    PubMed

    Skibins, Jeffrey C; Powell, Robert B

    2013-01-01

    Zoos in the 21st century are striving to make effective contributions to conservation. Although zoos are extremely popular and host over 600 million visitors worldwide, one challenge zoos face is how to effectively engage visitors and raise awareness and action for conservation. To this end, zoos commonly rely on charismatic megafauna, which have been shown to elicit a connection with zoo visitors. However, little is known about how to measure a connection to a species or how this connection may influence conservation behaviors. This study had two sequential objectives. The first was to develop a scale to measure visitors' connection to a species (Conservation Caring). The second was to investigate the relationship of Conservation Caring to pro-conservation behaviors, following a zoo experience. Pre- (n = 411) and post-visit (n = 452) responses were collected from three sites in order to assess the reliability and validity of a scale to measure Conservation Caring. Structural equation modeling was used to explore the relationship between Conservation Caring and pro-conservation behaviors. Conservation Caring was deemed a valid and reliable scale and was a strong predictor of species oriented behaviors (β = 0.62), for example, "adopting" an animal, but a weak predictor for biodiversity oriented behaviors (β = 0.07), for example, supporting sustainability policies. Results support the role zoos can play in fostering a connection to wildlife and stimulating pro-conservation behaviors. Additionally, visitors connected to a wide array of animals. On the basis of these results, zoos may recruit a wider assemblage of species as potential flagships. © 2013 Wiley Periodicals, Inc.

  2. Does what you know matter? Investigating the relationship between mental models of climate change and pro-environmental behaviors

    NASA Astrophysics Data System (ADS)

    Davis, R.

    2013-12-01

    The purpose of this study is to test the conjecture that environmentally sustainable decisions and behaviors are related to individuals' conceptions of the natural world, in this case climate change; individuals' attitudes towards climate change; and the situations in which these decisions are made. The nature of mental models is an ongoing subject of disagreement. Some argue that mental models are coherent theories, much like scientific theories, that individuals employ systematically when reasoning about the world (Gopnik & Meltzoff, 1998). Others maintain that mental models are cobbled together from fragmented collections of ideas that are only loosely connected and context dependent (Disessa, 1988; Minstrell, 2000). It is likely that individuals sometimes reason about complex phenomena using systematic mental models and at other times reason using knowledge that is organized in fragmented pieces (Steedle & Shavelson, 2009). Thus, in measuring mental models of complex environmental systems, such as climate change, the assumption of systematicity may not be justified. Individuals may apply certain chains of reasoning in some contexts but not in others. The current study hypothesizes that an accurate mental model of climate change enables an individual to make effective evaluative judgments of environmental behavior options. The more an individual's mental model resembles that of an expert, the more consistent, accurate and automatic these judgments become. However, an accurate mental model is not sufficient to change environmental behavior. Real decisions and behaviors are products of a person-situation interaction: an interplay between psychosocial factors (such as knowledge and attitudes) and the situation in which the decision is made. This study investigates the relationship between both psychosocial and situational factors for climate change decisions. Data was collected from 436 adult participants through an online survey. The survey was comprised of

  3. An analytic model for accurate spring constant calibration of rectangular atomic force microscope cantilevers.

    PubMed

    Li, Rui; Ye, Hongfei; Zhang, Weisheng; Ma, Guojun; Su, Yewang

    2015-10-29

    Spring constant calibration of the atomic force microscope (AFM) cantilever is of fundamental importance for quantifying the force between the AFM cantilever tip and the sample. The calibration within the framework of thin plate theory undoubtedly has a higher accuracy and broader scope than that within the well-established beam theory. However, thin plate theory-based accurate analytic determination of the constant has been perceived as an extremely difficult issue. In this paper, we implement the thin plate theory-based analytic modeling for the static behavior of rectangular AFM cantilevers, which reveals that the three-dimensional effect and Poisson effect play important roles in accurate determination of the spring constants. A quantitative scaling law is found that the normalized spring constant depends only on the Poisson's ratio, normalized dimension and normalized load coordinate. Both the literature and our refined finite element model validate the present results. The developed model is expected to serve as the benchmark for accurate calibration of rectangular AFM cantilevers.

  4. Constraining the Dynamics of Periodic Behavior at Mt. Semeru, Indonesia, Combining Numerical Modeling and Field Measurements of Gas emission

    NASA Astrophysics Data System (ADS)

    Smekens, J.; Clarke, A. B.; De'Michieli Vitturi, M.; Moore, G. M.

    2012-12-01

    Mt. Semeru is one of the most active explosive volcanoes on the island of Java in Indonesia. The current eruption style consists of small but frequent explosions and/or gas releases (several times a day) accompanied by continuous lava effusion that sporadically produces block-and-ash flows down the SE flank of the volcano. Semeru presents a unique opportunity to investigate the magma ascent conditions that produce this kind of persistent periodic behavior and the coexistence of explosive and effusive eruptions. In this work we use DOMEFLOW, a 1.5D transient isothermal numerical model, to investigate the dynamics of lava extrusion at Semeru. Petrologic observations from tephra and ballistic samples collected at the summit help us constrain the initial conditions of the system. Preliminary model runs produced periodic lava extrusion and pulses of gas release at the vent, with a cycle period on the order of hours, even though a steady magma supply rate was prescribed at the bottom of the conduit. Enhanced shallow permeability implemented in the model appears to create a dense plug in the shallow subsurface, which in turn plays a critical role in creating and controlling the observed periodic behavior. We measured SO2 fluxes just above the vent, using a custom UV imaging system. The device consists of two high-sensitivity CCD cameras with narrow UV filters centered at 310 and 330 nm, and a USB2000+ spectrometer for calibration and distance correction. The method produces high-frequency flux series with an accurate determination of the wind speed and plume geometry. The model results, when combined with gas measurements, and measurements of sulfur in both the groundmass and melt inclusions in eruptive products, could be used to create a volatile budget of the system. Furthermore, a well-calibrated model of the system will ultimately allow the characteristic periodicity and corresponding gas flux to be used as a proxy for magma supply rate.

  5. Rapid and Accurate Behavioral Health Diagnostic Screening: Initial Validation Study of a Web-Based, Self-Report Tool (the SAGE-SR)

    PubMed Central

    Purcell, Susan E; Rhea, Karen; Maier, Philip; First, Michael; Zweede, Lisa; Sinisterra, Manuela; Nunn, M Brad; Austin, Marie-Paule; Brodey, Inger S

    2018-01-01

    Background The Structured Clinical Interview for DSM (SCID) is considered the gold standard assessment for accurate, reliable psychiatric diagnoses; however, because of its length, complexity, and training required, the SCID is rarely used outside of research. Objective This paper aims to describe the development and initial validation of a Web-based, self-report screening instrument (the Screening Assessment for Guiding Evaluation-Self-Report, SAGE-SR) based on the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) and the SCID-5-Clinician Version (CV) intended to make accurate, broad-based behavioral health diagnostic screening more accessible within clinical care. Methods First, study staff drafted approximately 1200 self-report items representing individual granular symptoms in the diagnostic criteria for the 8 primary SCID-CV modules. An expert panel iteratively reviewed, critiqued, and revised items. The resulting items were iteratively administered and revised through 3 rounds of cognitive interviewing with community mental health center participants. In the first 2 rounds, the SCID was also administered to participants to directly compare their Likert self-report and SCID responses. A second expert panel evaluated the final pool of items from cognitive interviewing and criteria in the DSM-5 to construct the SAGE-SR, a computerized adaptive instrument that uses branching logic from a screener section to administer appropriate follow-up questions to refine the differential diagnoses. The SAGE-SR was administered to healthy controls and outpatient mental health clinic clients to assess test duration and test-retest reliability. Cutoff scores for screening into follow-up diagnostic sections and criteria for inclusion of diagnoses in the differential diagnosis were evaluated. Results The expert panel reduced the initial 1200 test items to 664 items that panel members agreed collectively represented the SCID items from the 8 targeted

  6. Is Oral Temperature an Accurate Measurement of Deep Body Temperature? A Systematic Review

    PubMed Central

    Mazerolle, Stephanie M.; Ganio, Matthew S.; Casa, Douglas J.; Vingren, Jakob; Klau, Jennifer

    2011-01-01

    Context: Oral temperature might not be a valid method to assess core body temperature. However, many clinicians, including athletic trainers, use it rather than criterion standard methods, such as rectal thermometry. Objective: To critically evaluate original research addressing the validity of using oral temperature as a measurement of core body temperature during periods of rest and changing core temperature. Data Sources: In July 2010, we searched the electronic databases PubMed, Scopus, Cumulative Index to Nursing and Allied Health Literature (CINAHL), SPORTDiscus, Academic Search Premier, and the Cochrane Library for the following concepts: core body temperature, oral, and thermometers. Controlled vocabulary was used, when available, as well as key words and variations of those key words. The search was limited to articles focusing on temperature readings and studies involving human participants. Data Synthesis: Original research was reviewed using the Physiotherapy Evidence Database (PEDro). Sixteen studies met the inclusion criteria and subsequently were evaluated by 2 independent reviewers. All 16 were included in the review because they met the minimal PEDro score of 4 points (of 10 possible points), with all but 2 scoring 5 points. A critical review of these studies indicated a disparity between oral and criterion standard temperature methods (eg, rectal and esophageal) specifically as the temperature increased. The difference was −0.50°C ± 0.31°C at rest and −0.58°C ± 0.75°C during a nonsteady state. Conclusions: Evidence suggests that, regardless of whether the assessment is recorded at rest or during periods of changing core temperature, oral temperature is an unsuitable diagnostic tool for determining body temperature because many measures demonstrated differences greater than the predetermined validity threshold of 0.27°C (0.5°F). In addition, the differences were greatest at the highest rectal temperatures. Oral temperature cannot

  7. Relationship between Adolescent Risk Preferences on a Laboratory Task and Behavioral Measures of Risk-taking

    PubMed Central

    Rao, Uma; Sidhartha, Tanuj; Harker, Karen R.; Bidesi, Anup S.; Chen, Li-Ann; Ernst, Monique

    2010-01-01

    Purpose The goal of the study was to assess individual differences in risk-taking behavior among adolescents in the laboratory. A second aim was to evaluate whether the laboratory-based risk-taking behavior is associated with other behavioral and psychological measures associated with risk-taking behavior. Methods Eighty-two adolescents with no personal history of psychiatric disorder completed a computerized decision-making task, the Wheel of Fortune (WOF). By offering choices between clearly defined probabilities and real monetary outcomes, this task assesses risk preferences when participants are confronted with potential rewards and losses. The participants also completed a variety of behavioral and psychological measures associated with risk-taking behavior. Results Performance on the task varied based on the probability and anticipated outcomes. In the winning sub-task, participants selected low probability-high magnitude reward (high-risk choice) less frequently than high probability-low magnitude reward (low-risk choice). In the losing sub-task, participants selected low probability-high magnitude loss more often than high probability-low magnitude loss. On average, the selection of probabilistic rewards was optimal and similar to performance in adults. There were, however, individual differences in performance, and one-third of the adolescents made high-risk choice more frequently than low-risk choice while selecting a reward. After controlling for sociodemographic and psychological variables, high-risk choice on the winning task predicted “real-world” risk-taking behavior and substance-related problems. Conclusions These findings highlight individual differences in risk-taking behavior. Preliminary data on face validity of the WOF task suggest that it might be a valuable laboratory tool for studying behavioral and neurobiological processes associated with risk-taking behavior in adolescents. PMID:21257113

  8. Hiding the word: examining the relationship between a new measure of religiosity and sexual behavior.

    PubMed

    Young, Michael; Denny, George; Penhollow, Tina; Palacios, Rebecca; Morris, Duston

    2015-06-01

    The relationship between religiosity and sexual behavior has been previously investigated, but researchers have not examined the relationship between the intellectual dimension of religiosity and sexual behavior. In this study, we developed an intellectual measure of religiosity, Hiding the Word (HTW), and examined whether it accounted for variation in the sexual behavior of college students, beyond that for which age and a generic measure of religiosity could account. Results showed, after accounting for age and generic religiosity, HTW made a significant contribution to distinguishing between students who had, and those who had not, engaged in various sexual behaviors. For females, this was the case in three of the five behaviors examined (all except receiving oral sex and participating in unprotected penile-vaginal intercourse at most recent sexual encounter), and for males, two of the four behaviors (sexual intercourse and anal intercourse). HTW was less of a factor in accounting for variation in the frequency of participation. For males, HTW was significant for the frequency of participation in penile-vaginal intercourse, receiving oral sex, and the number of sexual partners in the last month. For females, HTW was significant only for the number of sexual partners in the last month. Thus, religiosity, and specifically HTW, seems to play more of a role in determining whether or not a person has participated in behavior, rather than in the frequency of participation.

  9. Blood-Pressure Measuring System Gives Accurate Graphic Output

    NASA Technical Reports Server (NTRS)

    1965-01-01

    The problem: To develop an instrument that will provide an external (indirect) measurement of arterial blood pressure in the form of an easily interpreted graphic trace that can be correlated with standard clinical blood-pressure measurements. From sphygmograms produced by conventional sphygmographs, it is very difficult to differentiate the systolic and diastolic blood-pressure pulses and to correlate these indices with the standard clinical values. It is nearly impossible to determine these indices when the subject is under physical or emotional stress. The solution: An electronic blood-pressure system, basically similar to conventional ausculatory sphygmomanometers, employing a standard occluding cuff, a gas-pressure source, and a gas-pressure regulator and valve. An electrical output transducer senses cuff pressure, and a microphone positioned on the brachial artery under the occluding cuff monitors the Korotkoff sounds from this artery. The output signals present the conventional systolic and diastolic indices in a clear, graphical display. The complete system also includes an electronic timer and cycle-control circuit.

  10. Lightdrum—Portable Light Stage for Accurate BTF Measurement on Site

    PubMed Central

    Havran, Vlastimil; Hošek, Jan; Němcová, Šárka; Čáp, Jiří; Bittner, Jiří

    2017-01-01

    We propose a miniaturised light stage for measuring the bidirectional reflectance distribution function (BRDF) and the bidirectional texture function (BTF) of surfaces on site in real world application scenarios. The main principle of our lightweight BTF acquisition gantry is a compact hemispherical skeleton with cameras along the meridian and with light emitting diode (LED) modules shining light onto a sample surface. The proposed device is portable and achieves a high speed of measurement while maintaining high degree of accuracy. While the positions of the LEDs are fixed on the hemisphere, the cameras allow us to cover the range of the zenith angle from 0∘ to 75∘ and by rotating the cameras along the axis of the hemisphere we can cover all possible camera directions. This allows us to take measurements with almost the same quality as existing stationary BTF gantries. Two degrees of freedom can be set arbitrarily for measurements and the other two degrees of freedom are fixed, which provides a tradeoff between accuracy of measurements and practical applicability. Assuming that a measured sample is locally flat and spatially accessible, we can set the correct perpendicular direction against the measured sample by means of an auto-collimator prior to measuring. Further, we have designed and used a marker sticker method to allow for the easy rectification and alignment of acquired images during data processing. We show the results of our approach by images rendered for 36 measured material samples. PMID:28241466

  11. Concurrent Validity of the Strength-Based "Behavioral Objective Sequence"

    ERIC Educational Resources Information Center

    Wilder, Lynn K.; Braaten, Sheldon; Wilhite, Kathi; Algozzine, Bob

    2006-01-01

    An essential task of diagnosticians is the accurate assessment of behavioral skills. Traditionally, deficit-based behavioral assessments have underscored student social skill deficits. Strength-based assessments delineate student competencies and are useful for individualized education program (IEP) and behavioral intervention plan (BIP)…

  12. Short communication: measures of weight distribution and frequency of steps as indicators of restless behavior.

    PubMed

    Chapinal, N; de Passillé, A M; Rushen, J; Tucker, C B

    2011-02-01

    Restless behavior, as measured by the steps taken or weight shifting between legs, may be a useful tool to assess the comfort of dairy cattle. These behaviors increase when cows stand on uncomfortable surfaces or are lame. The objective of this study was to compare 2 measures of restless behavior, stepping behavior and changes in weight distribution, on 2 standing surfaces: concrete and rubber. Twelve cows stood on a weighing platform with 1 scale/hoof for 1h. The platform was covered with either concrete or rubber, presented in a crossover design. Restlessness, as measured by both the frequency of steps and weight shifting (measured as the standard deviation of weight applied over time to the legs), increased over 1h of forced standing on either concrete or rubber. A positive relationship was found between the frequency of steps and the standard deviation of weight over 1h for both treatments and pairs of legs (r ≥ 0.66). No differences existed in the standard deviation of weight applied to the front (27.6 ± 1.6 kg) or rear legs (33.5 ± 1.4 kg) or the frequency of steps (10.2 ± 1.6 and 20.8 ± 3.2 steps/10 min for the front and rear pair, respectively) between rubber and concrete. Measures of restlessness are promising tools for assessing specific types of discomfort, such as those associated with lameness, but additional tools are needed to assess comfort of non-concrete standing surfaces. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  13. Measuring cervical cancer risk: development and validation of the CARE Risky Sexual Behavior Index.

    PubMed

    Reiter, Paul L; Katz, Mira L; Ferketich, Amy K; Ruffin, Mack T; Paskett, Electra D

    2009-12-01

    To develop and validate a risky sexual behavior index specific to cervical cancer research. Sexual behavior data on 428 women from the Community Awareness Resources and Education (CARE) study were utilized. A weighting scheme for eight risky sexual behaviors was generated and validated in creating the CARE Risky Sexual Behavior Index. Cutpoints were then identified to classify women as having a low, medium, or high level of risky sexual behavior. Index scores ranged from 0 to 35, with women considered to have a low level of risky sexual behavior if their score was less than six (31.3% of sample), a medium level if their score was 6–10 (30.6%), or a high level if their score was 11 or greater (38.1%). A strong association was observed between the created categories and having a previous abnormal Pap smear test (p < 0.001). The CARE Risky Sexual Behavior Index provides a tool for measuring risky sexual behavior level for cervical cancer research. Future studies are needed to validate this index in varied populations and test its use in the clinical setting.

  14. Multiaxial constitutive behavior of an interstitial-free steel: Measurements through X-ray and digital image correlation

    PubMed Central

    Jeong, Y.; Iadicola, M.A.; Gnäupel-Herold, T.; Creuziger, A.

    2017-01-01

    Constitutive behaviors of an interstitial-free steel sample were measured using an augmented Marciniak experiment. In these tests, multiaxial strain field data of the flat specimens were measured by the digital image correlation technique. In addition, the flow stress was measured using an X-ray diffractometer. The flat specimens in three different geometries were tested in order to achieve 1) balanced biaxial strain, and plane strain tests with zero strain in either 2) rolling direction or 3) transverse direction. The multiaxial stress and strain data were processed to obtain plastic work contours with reference to a uniaxial tension test along the rolling direction. The experimental results show that the mechanical behavior of the subjected specimen deviates significantly from isotropic behavior predicted by the von Mises yield criterion. The initial yield loci measured by a Marciniak tester is in good agreement with what is predicted by Hill's yield criterion. However, as deformation increases beyond the vonMises strain of 0.05, the shape of the work contour significantly deviates from that of Hill's yield locus. A prediction made by a viscoplastic self-consistent model is in better agreement with the experimental observation than the Hill yield locus with the isotropic work-hardening rule. However, none of the studied models matched the initial or evolving anisotropic behaviors of the interstitial-free steel measured by the augmented Marciniak experiment. PMID:28690400

  15. Multiaxial constitutive behavior of an interstitial-free steel: Measurements through X-ray and digital image correlation.

    PubMed

    Jeong, Y; Iadicola, M A; Gnäupel-Herold, T; Creuziger, A

    2016-06-15

    Constitutive behaviors of an interstitial-free steel sample were measured using an augmented Marciniak experiment. In these tests, multiaxial strain field data of the flat specimens were measured by the digital image correlation technique. In addition, the flow stress was measured using an X-ray diffractometer. The flat specimens in three different geometries were tested in order to achieve 1) balanced biaxial strain, and plane strain tests with zero strain in either 2) rolling direction or 3) transverse direction. The multiaxial stress and strain data were processed to obtain plastic work contours with reference to a uniaxial tension test along the rolling direction. The experimental results show that the mechanical behavior of the subjected specimen deviates significantly from isotropic behavior predicted by the von Mises yield criterion. The initial yield loci measured by a Marciniak tester is in good agreement with what is predicted by Hill's yield criterion. However, as deformation increases beyond the vonMises strain of 0.05, the shape of the work contour significantly deviates from that of Hill's yield locus. A prediction made by a viscoplastic self-consistent model is in better agreement with the experimental observation than the Hill yield locus with the isotropic work-hardening rule. However, none of the studied models matched the initial or evolving anisotropic behaviors of the interstitial-free steel measured by the augmented Marciniak experiment.

  16. Nonsuicidal Self-Injury: Relationship to Behavioral and Self-Rating Measures of Impulsivity and Self-Aggression

    ERIC Educational Resources Information Center

    Mc Closkey, Michael S.; Look, Amy E.; Chen, Eunice Y.; Pajoumand, Golnaz; Berman, Mitchell E.

    2012-01-01

    Previous research using self-report measures has shown an association between nonsuicidal self-injurious behavior (NSSI) and impulsive tendencies. However, self-injurers have not been shown to be different from comparison groups on laboratory tasks putatively assessing impulsive behavior. One explanation for these contradictory findings is that…

  17. Stimulating innovations in the measurement of parenting constructs.

    PubMed

    Mâsse, Louise C; Watts, Allison W

    2013-08-01

    Parents can play a crucial role in the development of children's behaviors associated with dietary habits, physical activity, and sedentary lifestyles. Many parenting practices and/or styles measures have been developed; however, there is little agreement as to how the influence of parenting should be measured. More importantly, our ability to relate parenting practices and/or styles to children's behaviors depends on its accurate assessment. While there is a need to standardize our assessment to further advance knowledge in this area, this article will discuss areas that may stimulate advances in the measurement of parenting constructs. Because self-report measures are important for the assessment of parenting, this article discusses whether solutions to improve self-report measures may lie in: (1) Improving the questions asked; (2) improving the methods used to correct for social desirability or measurement errors; (3) changing our measurement paradigm to assess implicit parenting behaviors; (4) changing how self-report is collected by taking advantage of ecological momentary assessment methods; (5) using better psychometric methods to validate parenting measures or alternatively using advances in psychometric methods, such as item banking and computerized adaptive testing, to solve common administration issues (i.e., response burden and comparability of results across studies); and (6) employing novel technologies to collect data such as portable technologies, gaming, and virtual reality simulation. This article will briefly discuss the potential of technologies to measure parenting constructs.

  18. Stimulating Innovations in the Measurement of Parenting Constructs

    PubMed Central

    Watts, Allison W.

    2013-01-01

    Abstract Parents can play a crucial role in the development of children's behaviors associated with dietary habits, physical activity, and sedentary lifestyles. Many parenting practices and/or styles measures have been developed; however, there is little agreement as to how the influence of parenting should be measured. More importantly, our ability to relate parenting practices and/or styles to children's behaviors depends on its accurate assessment. While there is a need to standardize our assessment to further advance knowledge in this area, this article will discuss areas that may stimulate advances in the measurement of parenting constructs. Because self-report measures are important for the assessment of parenting, this article discusses whether solutions to improve self-report measures may lie in: (1) Improving the questions asked; (2) improving the methods used to correct for social desirability or measurement errors; (3) changing our measurement paradigm to assess implicit parenting behaviors; (4) changing how self-report is collected by taking advantage of ecological momentary assessment methods; (5) using better psychometric methods to validate parenting measures or alternatively using advances in psychometric methods, such as item banking and computerized adaptive testing, to solve common administration issues (i.e., response burden and comparability of results across studies); and (6) employing novel technologies to collect data such as portable technologies, gaming, and virtual reality simulation. This article will briefly discuss the potential of technologies to measure parenting constructs. PMID:23944924

  19. The Prison Adjusted Measure of Aggression (PAMA): Psychometric characteristics of a new tool measuring change in aggressive behaviors in correctional settings.

    PubMed

    Kerekes, Nóra; Apelqvist, Susanne; Fielding, Cecilia; Anckarsäter, Henrik; Nilsson, Thomas

    2018-05-01

    There is a need for instruments that can be used in correctional settings to measure changes in aggressive behaviors over a limited time period. This study aimed to validate an instrument (the Prison Adjusted Measure of Aggression, PAMA) that assesses specifically the past month's aggressive behaviors and is adapted for use in correctional facilities. The psychometric properties of the self-rated and interview versions of the PAMA were explored and compared to those of two well-established measures of aggression: The Staff Observation Aggression Scale (SOAS); and the self-rate Aggression Questionnaire-Revised Swedish Version (AQ-RSV). The study group comprised 93 male and 59 female inmates, who were followed for two months. During the study, the prevalence of aggressive acts was observed and reported by SOAS. On two occasions, at monthly intervals, subjects reported their own aggressive behaviors using AQ-RSV and the self-report version of the PAMA; also, a psychologist conducted interviews according to PAMA. This study's main finding was that the self-rated version of PAMA is a valid measure of different types and dimensions of aggression (physical and verbal aggression, hostility) and has acceptable psychometric properties. Therefore, PAMA could potentially be of value for use in correctional services evaluating aggression managing treatment interventions. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  20. SU-F-BRF-13: Investigating the Feasibility of Accurate Dose Measurement in a Deforming Radiochromic Dosimeter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Juang, T; Adamovics, J; Oldham, M

    Purpose: Presage-Def, a deformable radiochromic 3D dosimeter, has been previously shown to have potential for validating deformable image registration algorithms. This work extends this effort to investigate the feasibility of using Presage-Def to validate dose-accumulation algorithms in deforming structures. Methods: Two cylindrical Presage-Def dosimeters (8cm diameter, 4.5cm length) were irradiated in a water-bath with a simple 4-field box treatment. Isocentric dose was 20Gy. One dosimeter served as control (no deformation) while the other was laterally compressed during irradiation by 21%. Both dosimeters were imaged before and after irradiation with a fast (∼10 minutes for 1mm isotropic resolution), broad beam, highmore » resolution optical-CT scanner. Measured dose distributions were compared to corresponding distributions calculated by a commissioned Eclipse planning system. Accuracy in the control was evaluated with 3D gamma (3%/3mm). The dose distribution calculated for the compressed dosimeter in the irradiation geometry cannot be directly compared via profiles or 3D gamma to the measured distribution, which deforms with release from compression. Thus, accuracy under deformation was determined by comparing integral dose within the high dose region of the deformed dosimeter distribution versus calculated dose. Dose profiles were used to study temporal stability of measured dose distributions. Results: Good dose agreement was demonstrated in the control with a 3D gamma passing rate of 96.6%. For the dosimeter irradiated under compression, the measured integral dose in the high dose region (518.0Gy*cm3) was within 6% of the Eclipse-calculated integral dose (549.4Gy*cm3). Elevated signal was noted on the dosimeter edge in the direction of compression. Change in dosimeter signal over 1.5 hours was ≤2.7%, and the relative dose distribution remained stable over this period of time. Conclusion: Presage-Def is promising as a 3D dosimeter capable of accurately

  1. The use of multiple imputation for the accurate measurements of individual feed intake by electronic feeders.

    PubMed

    Jiao, S; Tiezzi, F; Huang, Y; Gray, K A; Maltecca, C

    2016-02-01

    Obtaining accurate individual feed intake records is the key first step in achieving genetic progress toward more efficient nutrient utilization in pigs. Feed intake records collected by electronic feeding systems contain errors (erroneous and abnormal values exceeding certain cutoff criteria), which are due to feeder malfunction or animal-feeder interaction. In this study, we examined the use of a novel data-editing strategy involving multiple imputation to minimize the impact of errors and missing values on the quality of feed intake data collected by an electronic feeding system. Accuracy of feed intake data adjustment obtained from the conventional linear mixed model (LMM) approach was compared with 2 alternative implementations of multiple imputation by chained equation, denoted as MI (multiple imputation) and MICE (multiple imputation by chained equation). The 3 methods were compared under 3 scenarios, where 5, 10, and 20% feed intake error rates were simulated. Each of the scenarios was replicated 5 times. Accuracy of the alternative error adjustment was measured as the correlation between the true daily feed intake (DFI; daily feed intake in the testing period) or true ADFI (the mean DFI across testing period) and the adjusted DFI or adjusted ADFI. In the editing process, error cutoff criteria are used to define if a feed intake visit contains errors. To investigate the possibility that the error cutoff criteria may affect any of the 3 methods, the simulation was repeated with 2 alternative error cutoff values. Multiple imputation methods outperformed the LMM approach in all scenarios with mean accuracies of 96.7, 93.5, and 90.2% obtained with MI and 96.8, 94.4, and 90.1% obtained with MICE compared with 91.0, 82.6, and 68.7% using LMM for DFI. Similar results were obtained for ADFI. Furthermore, multiple imputation methods consistently performed better than LMM regardless of the cutoff criteria applied to define errors. In conclusion, multiple imputation

  2. Aptamer-conjugated live human immune cell based biosensors for the accurate detection of C-reactive protein

    NASA Astrophysics Data System (ADS)

    Hwang, Jangsun; Seo, Youngmin; Jo, Yeonho; Son, Jaewoo; Choi, Jonghoon

    2016-10-01

    C-reactive protein (CRP) is a pentameric protein that is present in the bloodstream during inflammatory events, e.g., liver failure, leukemia, and/or bacterial infection. The level of CRP indicates the progress and prognosis of certain diseases; it is therefore necessary to measure CRP levels in the blood accurately. The normal concentration of CRP is reported to be 1-3 mg/L. Inflammatory events increase the level of CRP by up to 500 times; accordingly, CRP is a biomarker of acute inflammatory disease. In this study, we demonstrated the preparation of DNA aptamer-conjugated peripheral blood mononuclear cells (Apt-PBMCs) that specifically capture human CRP. Live PBMCs functionalized with aptamers could detect different levels of human CRP by producing immune complexes with reporter antibody. The binding behavior of Apt-PBMCs toward highly concentrated CRP sites was also investigated. The immune responses of Apt-PBMCs were evaluated by measuring TNF-alpha secretion after stimulating the PBMCs with lipopolysaccharides. In summary, engineered Apt-PBMCs have potential applications as live cell based biosensors and for in vitro tracing of CRP secretion sites.

  3. Simulation of Thermo-viscoplastic Behaviors for AISI 4140 Steel

    NASA Astrophysics Data System (ADS)

    Li, Hong-Bin; Feng, Yun-Li

    2016-04-01

    The thermo-viscoplastic behaviors of AISI 4140 steel are investigated over wide ranges of strain rate and deformation temperature by isothermal compression tests. Based on the experimental results, a unified viscoplastic constitutive model is proposed to describe the hot compressive deformation behaviors of the studied steel. In order to reasonably evaluate the work hardening behaviors, a strain hardening material constant (h0) is expressed as a function of deformation temperature and strain rate in the proposed constitutive model. Also, the sensitivity of initial value of internal variable s to the deformation temperature is discussed. Furthermore, it is found that the initial value of internal variable s can be expressed as a linear function of deformation temperature. Comparisons between the measured and predicted results confirm that the proposed constitutive model can give an accurate and precise estimate of the inelastic stress-strain relationships for the studied high-strength steel.

  4. Performance-based measures and behavioral ratings of executive function in diagnosing attention-deficit/hyperactivity disorder in children.

    PubMed

    Tan, Alexander; Delgaty, Lauren; Steward, Kayla; Bunner, Melissa

    2018-04-16

    Deficits in real-world executive functioning (EF) are a frequent characteristic of attention-deficit/hyperactivity disorder (ADHD). However, the predictive value of using performance-based and behavioral rating measures of EF when diagnosing ADHD remains unclear. The current study investigates the use of performance-based EF measures and a parent-report questionnaire with established ecological validity and clinical utility when diagnosing ADHD. Participants included 21 healthy controls, 21 ADHD-primary inattentive, and 21 ADHD-combined type subjects aged 6-15 years. A brief neuropsychological battery was administered to each subject including common EF assessment measures. Significant differences were not found between groups on most performance-based EF measures, whereas significant differences (p < 0.05) were found on most parent-report behavioral rating scales. Furthermore, performance-based measures did not predict group membership above chance levels. Results further support differences in predictive value of EF performance-based measures compared to parent-report questionnaires when diagnosing ADHD. Further research must investigate the relationship between performance-based and behavioral rating measures when assessing EF in ADHD.

  5. Conversion of calibration curves for accurate estimation of molecular weight averages and distributions of polyether polyols by conventional size exclusion chromatography.

    PubMed

    Xu, Xiuqing; Yang, Xiuhan; Martin, Steven J; Mes, Edwin; Chen, Junlan; Meunier, David M

    2018-08-17

    Accurate measurement of molecular weight averages (M¯ n, M¯ w, M¯ z ) and molecular weight distributions (MWD) of polyether polyols by conventional SEC (size exclusion chromatography) is not as straightforward as it would appear. Conventional calibration with polystyrene (PS) standards can only provide PS apparent molecular weights which do not provide accurate estimates of polyol molecular weights. Using polyethylene oxide/polyethylene glycol (PEO/PEG) for molecular weight calibration could improve the accuracy, but the retention behavior of PEO/PEG is not stable in THF-based (tetrahydrofuran) SEC systems. In this work, two approaches for calibration curve conversion with narrow PS and polyol molecular weight standards were developed. Equations to convert PS-apparent molecular weight to polyol-apparent molecular weight were developed using both a rigorous mathematical analysis and graphical plot regression method. The conversion equations obtained by the two approaches were in good agreement. Factors influencing the conversion equation were investigated. It was concluded that the separation conditions such as column batch and operating temperature did not have significant impact on the conversion coefficients and a universal conversion equation could be obtained. With this conversion equation, more accurate estimates of molecular weight averages and MWDs for polyether polyols can be achieved from conventional PS-THF SEC calibration. Moreover, no additional experimentation is required to convert historical PS equivalent data to reasonably accurate molecular weight results. Copyright © 2018. Published by Elsevier B.V.

  6. An efficient and inexpensive method for measuring long-term thermoregulatory behavior

    PubMed Central

    Sperry, Jinelle H.; Rohr, Jason R.

    2016-01-01

    Thermoregulatory ability and behavior influence organismal responses to their environment. By measuring thermal preferences, researchers can better understand the effects that temperature tolerances have on ecological and physiological responses to both biotic and abiotic stressors. However, because of funding limitations and confounders, measuring thermoregulation can often be difficult. Here, we provide an effective, affordable (∼$50 USD per unit), easy to construct, and validated apparatus for measuring the long-term thermal preferences of animals. In tests, the apparatus spanned temperatures from 9.29 to 33.94 °C, and we provide methods to further increase this range. Additionally, we provide simple methods to non-invasively measure animal and substrate temperatures and to prevent temperature preferences of the focal organisms from being confounded with temperature preferences of its prey and its humidity preferences. To validate the apparatus, we show that it was capable of detecting individual-level consistency and among individual-level variation in the preferred body temperatures of Southern toads (Anaxyrus terrestris) and Cuban tree frogs (Osteopilus septentrionalis) over three-weeks. Nearly every aspect of our design is adaptable to meet the needs of a multitude of study systems, including various terrestrial amphibious, and aquatic organisms. The apparatus and methods described here can be used to quantify behavioral thermal preferences, which can be critical for determining temperature tolerances across species and thus the resiliency of species to current and impending climate change. PMID:27503737

  7. Best methods for evaluating educational impact: a comparison of the efficacy of commonly used measures of library instruction

    PubMed Central

    Schilling, Katherine; Applegate, Rachel

    2012-01-01

    Objectives and Background: Libraries are increasingly called upon to demonstrate student learning outcomes and the tangible benefits of library educational programs. This study reviewed and compared the efficacy of traditionally used measures for assessing library instruction, examining the benefits and drawbacks of assessment measures and exploring the extent to which knowledge, attitudes, and behaviors actually paralleled demonstrated skill levels. Methods: An overview of recent literature on the evaluation of information literacy education addressed these questions: (1) What evaluation measures are commonly used for evaluating library instruction? (2) What are the pros and cons of popular evaluation measures? (3) What are the relationships between measures of skills versus measures of attitudes and behavior? Research outcomes were used to identify relationships between measures of attitudes, behaviors, and skills, which are typically gathered via attitudinal surveys, written skills tests, or graded exercises. Results and Conclusions: Results provide useful information about the efficacy of instructional evaluation methods, including showing significant disparities between attitudes, skills, and information usage behaviors. This information can be used by librarians to implement the most appropriate evaluation methods for measuring important variables that accurately demonstrate students' attitudes, behaviors, or skills. PMID:23133325

  8. Can numerical simulations accurately predict hydrodynamic instabilities in liquid films?

    NASA Astrophysics Data System (ADS)

    Denner, Fabian; Charogiannis, Alexandros; Pradas, Marc; van Wachem, Berend G. M.; Markides, Christos N.; Kalliadasis, Serafim

    2014-11-01

    Understanding the dynamics of hydrodynamic instabilities in liquid film flows is an active field of research in fluid dynamics and non-linear science in general. Numerical simulations offer a powerful tool to study hydrodynamic instabilities in film flows and can provide deep insights into the underlying physical phenomena. However, the direct comparison of numerical results and experimental results is often hampered by several reasons. For instance, in numerical simulations the interface representation is problematic and the governing equations and boundary conditions may be oversimplified, whereas in experiments it is often difficult to extract accurate information on the fluid and its behavior, e.g. determine the fluid properties when the liquid contains particles for PIV measurements. In this contribution we present the latest results of our on-going, extensive study on hydrodynamic instabilities in liquid film flows, which includes direct numerical simulations, low-dimensional modelling as well as experiments. The major focus is on wave regimes, wave height and wave celerity as a function of Reynolds number and forcing frequency of a falling liquid film. Specific attention is paid to the differences in numerical and experimental results and the reasons for these differences. The authors are grateful to the EPSRC for their financial support (Grant EP/K008595/1).

  9. Measuring Cultural Socialization Attitudes and Behaviors of Mexican-Origin Mothers With Young Children: A Longitudinal Investigation

    PubMed Central

    Derlan, Chelsea L.; Umaña-Taylor, Adriana J.; Toomey, Russell B.; Jahromi, Laudan B.; Updegraff, Kimberly A.

    2016-01-01

    We describe the development and psychometric testing of the Cultural Socialization Behaviors Measure (CSBM) and the Cultural Socialization Attitudes Measure (CSAM). The CSBM assesses cultural socialization behaviors that parents use with young children, and the CSAM assesses the attitudes that parents have regarding the importance of socializing their young children about their culture. Both measures demonstrated strong reliability, validity, and cross-language equivalence (i.e., Spanish and English) among a sample of 204 Mexican-origin young mothers (Mage = 20.94 years, SD = 1.01) with 4-year-old children. In addition, the measures demonstrated longitudinal equivalence when children were 4 and 5 years of age. PMID:27990040

  10. Measuring Cultural Socialization Attitudes and Behaviors of Mexican-Origin Mothers With Young Children: A Longitudinal Investigation.

    PubMed

    Derlan, Chelsea L; Umaña-Taylor, Adriana J; Toomey, Russell B; Jahromi, Laudan B; Updegraff, Kimberly A

    2016-07-01

    We describe the development and psychometric testing of the Cultural Socialization Behaviors Measure (CSBM) and the Cultural Socialization Attitudes Measure (CSAM). The CSBM assesses cultural socialization behaviors that parents use with young children, and the CSAM assesses the attitudes that parents have regarding the importance of socializing their young children about their culture. Both measures demonstrated strong reliability, validity, and cross-language equivalence (i.e., Spanish and English) among a sample of 204 Mexican-origin young mothers ( M age = 20.94 years, SD = 1.01) with 4-year-old children. In addition, the measures demonstrated longitudinal equivalence when children were 4 and 5 years of age.

  11. Are Fluency Measures Accurate Predictors of Reading Achievement?

    ERIC Educational Resources Information Center

    Schilling, Stephen G.; Carlisle, Joanne F.; Scott, Sarah E.; Zeng, Ji

    2007-01-01

    This study focused on the predictive validity of fluency measures that comprise Dynamic Indicators of Basic Early Literacy Skills (DIBELS). Data were gathered from first through third graders attending 44 schools in 9 districts or local educational agencies that made up the first Reading First cohort in Michigan. Students were administered DIBELS…

  12. Accurate Monitoring and Fault Detection in Wind Measuring Devices through Wireless Sensor Networks

    PubMed Central

    Khan, Komal Saifullah; Tariq, Muhammad

    2014-01-01

    Many wind energy projects report poor performance as low as 60% of the predicted performance. The reason for this is poor resource assessment and the use of new untested technologies and systems in remote locations. Predictions about the potential of an area for wind energy projects (through simulated models) may vary from the actual potential of the area. Hence, introducing accurate site assessment techniques will lead to accurate predictions of energy production from a particular area. We solve this problem by installing a Wireless Sensor Network (WSN) to periodically analyze the data from anemometers installed in that area. After comparative analysis of the acquired data, the anemometers transmit their readings through a WSN to the sink node for analysis. The sink node uses an iterative algorithm which sequentially detects any faulty anemometer and passes the details of the fault to the central system or main station. We apply the proposed technique in simulation as well as in practical implementation and study its accuracy by comparing the simulation results with experimental results to analyze the variation in the results obtained from both simulation model and implemented model. Simulation results show that the algorithm indicates faulty anemometers with high accuracy and low false alarm rate when as many as 25% of the anemometers become faulty. Experimental analysis shows that anemometers incorporating this solution are better assessed and performance level of implemented projects is increased above 86% of the simulated models. PMID:25421739

  13. Accurate physical laws can permit new standard units: The two laws F→=ma→ and the proportionality of weight to mass

    NASA Astrophysics Data System (ADS)

    Saslow, Wayne M.

    2014-04-01

    Three common approaches to F→=ma→ are: (1) as an exactly true definition of force F→ in terms of measured inertial mass m and measured acceleration a→; (2) as an exactly true axiom relating measured values of a→, F→ and m; and (3) as an imperfect but accurately true physical law relating measured a→ to measured F→, with m an experimentally determined, matter-dependent constant, in the spirit of the resistance R in Ohm's law. In the third case, the natural units are those of a→ and F→, where a→ is normally specified using distance and time as standard units, and F→ from a spring scale as a standard unit; thus mass units are derived from force, distance, and time units such as newtons, meters, and seconds. The present work develops the third approach when one includes a second physical law (again, imperfect but accurate)—that balance-scale weight W is proportional to m—and the fact that balance-scale measurements of relative weight are more accurate than those of absolute force. When distance and time also are more accurately measurable than absolute force, this second physical law permits a shift to standards of mass, distance, and time units, such as kilograms, meters, and seconds, with the unit of force—the newton—a derived unit. However, were force and distance more accurately measurable than time (e.g., time measured with an hourglass), this second physical law would permit a shift to standards of force, mass, and distance units such as newtons, kilograms, and meters, with the unit of time—the second—a derived unit. Therefore, the choice of the most accurate standard units depends both on what is most accurately measurable and on the accuracy of physical law.

  14. Extracting Time-Accurate Acceleration Vectors From Nontrivial Accelerometer Arrangements.

    PubMed

    Franck, Jennifer A; Blume, Janet; Crisco, Joseph J; Franck, Christian

    2015-09-01

    Sports-related concussions are of significant concern in many impact sports, and their detection relies on accurate measurements of the head kinematics during impact. Among the most prevalent recording technologies are videography, and more recently, the use of single-axis accelerometers mounted in a helmet, such as the HIT system. Successful extraction of the linear and angular impact accelerations depends on an accurate analysis methodology governed by the equations of motion. Current algorithms are able to estimate the magnitude of acceleration and hit location, but make assumptions about the hit orientation and are often limited in the position and/or orientation of the accelerometers. The newly formulated algorithm presented in this manuscript accurately extracts the full linear and rotational acceleration vectors from a broad arrangement of six single-axis accelerometers directly from the governing set of kinematic equations. The new formulation linearizes the nonlinear centripetal acceleration term with a finite-difference approximation and provides a fast and accurate solution for all six components of acceleration over long time periods (>250 ms). The approximation of the nonlinear centripetal acceleration term provides an accurate computation of the rotational velocity as a function of time and allows for reconstruction of a multiple-impact signal. Furthermore, the algorithm determines the impact location and orientation and can distinguish between glancing, high rotational velocity impacts, or direct impacts through the center of mass. Results are shown for ten simulated impact locations on a headform geometry computed with three different accelerometer configurations in varying degrees of signal noise. Since the algorithm does not require simplifications of the actual impacted geometry, the impact vector, or a specific arrangement of accelerometer orientations, it can be easily applied to many impact investigations in which accurate kinematics need

  15. Development of an Instrument to Measure Behavioral Health Function for Work Disability: Item Pool Construction and Factor Analysis

    PubMed Central

    Marfeo, Elizabeth E.; Ni, Pengsheng; Haley, Stephen M.; Jette, Alan M.; Bogusz, Kara; Meterko, Mark; McDonough, Christine M.; Chan, Leighton; Brandt, Diane E.; Rasch, Elizabeth K.

    2014-01-01

    Objectives To develop a broad set of claimant-reported items to assess behavioral health functioning relevant to the Social Security disability determination processes, and to evaluate the underlying structure of behavioral health functioning for use in development of a new functional assessment instrument. Design Cross-sectional. Setting Community. Participants Item pools of behavioral health functioning were developed, refined, and field-tested in a sample of persons applying for Social Security disability benefits (N=1015) who reported difficulties working due to mental or both mental and physical conditions. Interventions None. Main Outcome Measure Social Security Administration Behavioral Health (SSA-BH) measurement instrument Results Confirmatory factor analysis (CFA) specified that a 4-factor model (self-efficacy, mood and emotions, behavioral control, and social interactions) had the optimal fit with the data and was also consistent with our hypothesized conceptual framework for characterizing behavioral health functioning. When the items within each of the four scales were tested in CFA, the fit statistics indicated adequate support for characterizing behavioral health as a unidimensional construct along these four distinct scales of function. Conclusion This work represents a significant advance both conceptually and psychometrically in assessment methodologies for work related behavioral health. The measurement of behavioral health functioning relevant to the context of work requires the assessment of multiple dimensions of behavioral health functioning. Specifically, we identified a 4-factor model solution that represented key domains of work related behavioral health functioning. These results guided the development and scale formation of a new SSA-BH instrument. PMID:23548542

  16. A Procedure to Measure the in-Situ Hygrothermal Behavior of Earth Walls

    PubMed Central

    Chabriac, Pierre-Antoine; Fabbri, Antonin; Morel, Jean-Claude; Laurent, Jean-Paul; Blanc-Gonnet, Joachim

    2014-01-01

    Rammed earth is a sustainable material with low embodied energy. However, its development as a building material requires a better evaluation of its moisture-thermal buffering abilities and its mechanical behavior. Both of these properties are known to strongly depend on the amount of water contained in wall pores and its evolution. Thus the aim of this paper is to present a procedure to measure this key parameter in rammed earth or cob walls by using two types of probes operating on the Time Domain Reflectometry (TDR) principle. A calibration procedure for the probes requiring solely four parameters is described. This calibration procedure is then used to monitor the hygrothermal behavior of a rammed earth wall (1.5 m × 1 m × 0.5 m), instrumented by six probes during its manufacture, and submitted to insulated, natural convection and forced convection conditions. These measurements underline the robustness of the calibration procedure over a large range of water content, even if the wall is submitted to quite important temperature variations. They also emphasize the importance of gravity on water content heterogeneity when the saturation is high, as well as the role of liquid-to-vapor phase change on the thermal behavior. PMID:28788603

  17. Development of an accurate EPID-based output measurement and dosimetric verification tool for electron beam therapy.

    PubMed

    Ding, Aiping; Xing, Lei; Han, Bin

    2015-07-01

    . The average discrepancy between EPID and ion chamber/film measurements was 0.81% ± 0.60% (SD) and 1.34% ± 0.75%, respectively. For the three clinical cases, the difference in output between the EPID- and ion chamber array measured values was found to be 1.13% ± 0.11%, 0.54% ± 0.10%, and 0.74% ± 0.11%, respectively. Furthermore, the γ-index analysis showed an excellent agreement between the EPID- and ion chamber array measured dose distributions: 100% of the pixels passed the criteria of 3%/3 mm. When the γ-index was set to be 2%/2 mm, the pass rate was found to be 99.0% ± 0.07%, 98.2% ± 0.14%, and 100% for the three cases. The EPID dosimetry system developed in this work provides an accurate and reliable tool for routine output measurement and dosimetric verification of electron beam therapy. Coupled with its portability and ease of use, the proposed system promises to replace the current film-based approach for fast and reliable assessment of small and irregular electron field dosimetry.

  18. Mixed sand and gravel beaches: accurate measurement of active layer depth and sediment transport volumes using PIT tagged tracer pebbles

    NASA Astrophysics Data System (ADS)

    Holland, A.; Moses, C.; Sear, D. A.; Cope, S.

    2016-12-01

    As sediments containing significant gravel portions are increasingly used for beach replenishment projects globally, the total number of beaches classified as `mixed sand and gravel' (MSG) increases. Calculations for required replenishment sediment volumes usually assume a uniform layer of sediment transport across and along the beach, but research into active layer (AL) depth has shown variations both across shore and according to sediment size distribution. This study addresses the need for more accurate calculations of sediment transport volumes on MSG beaches by using more precise measurements of AL depth and width, and virtual velocity of tracer pebbles. Variations in AL depth were measured along three main profile lines (from MHWS to MLWN) at Eastoke, Hayling Island (Hampshire, UK). Passive Integrated Transponder (PIT) tagged pebbles were deployed in columns, and their new locations repeatedly surveyed with RFID technology. These data were combined with daily dGPS beach profiles and sediment sampling for detailed analysis of the influence of beach morphodynamics on sediment transport volumes. Data were collected over two consecutive winter seasons: 2014-15 (relatively calm, average wave height <1 m) and 2015-16 (prolonged periods of moderate storminess, wave heights of 1-2 m). The active layer was, on average, 22% of wave height where beach slope (tanβ) is 0.1, with variations noted according to slope angle, sediment distribution, and beach groundwater level. High groundwater levels and a change in sediment proportions in the sandy lower foreshore reduced the AL to 10% of wave height in this area. The disparity in AL depth across the beach profile indicates that traditional models are not accurately representing bulk sediment transport on MSG beaches. It is anticipated that by improving model inputs, beach managers will be better able to predict necessary volumes and sediment grain size proportions of replenishment material for effective management of MSG

  19. Accurate Nanoscale Crystallography in Real-Space Using Scanning Transmission Electron Microscopy.

    PubMed

    Dycus, J Houston; Harris, Joshua S; Sang, Xiahan; Fancher, Chris M; Findlay, Scott D; Oni, Adedapo A; Chan, Tsung-Ta E; Koch, Carl C; Jones, Jacob L; Allen, Leslie J; Irving, Douglas L; LeBeau, James M

    2015-08-01

    Here, we report reproducible and accurate measurement of crystallographic parameters using scanning transmission electron microscopy. This is made possible by removing drift and residual scan distortion. We demonstrate real-space lattice parameter measurements with <0.1% error for complex-layered chalcogenides Bi2Te3, Bi2Se3, and a Bi2Te2.7Se0.3 nanostructured alloy. Pairing the technique with atomic resolution spectroscopy, we connect local structure with chemistry and bonding. Combining these results with density functional theory, we show that the incorporation of Se into Bi2Te3 causes charge redistribution that anomalously increases the van der Waals gap between building blocks of the layered structure. The results show that atomic resolution imaging with electrons can accurately and robustly quantify crystallography at the nanoscale.

  20. Developing a measure of provider adherence to improve the implementation of behavioral health services in primary care: a Delphi study

    PubMed Central

    2013-01-01

    Background The integration of behavioral health services into primary care is increasingly popular, yet fidelity of implementation in this area has been infrequently assessed due to the few measurement tools available. A sentinel indicator of fidelity of implementation is provider adherence, or utilization of prescribed procedures and engagement in model-specific behaviors. This study aimed to develop the first self-report measure of behavioral health provider adherence for co-located, collaborative care, a commonly adopted model of behavioral health service delivery in primary care. Methods A preliminary 56-item measure was developed by the research team to represent critical components of adherence among behavioral health providers. To ensure the content validity of the measure, a modified Delphi study was conducted using a panel of co-located, collaborative care model experts. During three rounds of emailed surveys, panel members provided qualitative feedback regarding item content while rating each item’s relevance for behavioral health provider practice. Items with consensus ratings of 80% or greater were included in the final adherence measure. Results The panel consisted of 25 experts representing the Department of Veterans Affairs, the Department of Defense, and academic and community health centers (total study response rate of 76%). During the Delphi process, two new items were added to the measure, four items were eliminated, and a high level of consensus was achieved on the remaining 54 items. Experts identified 38 items essential for model adherence, six items compatible (although not essential) for model adherence, and 10 items that represented prohibited behaviors. Item content addressed several domains, but primarily focused on behaviors related to employing a time-limited, brief treatment model, the scope of patient concerns addressed, and interventions used by providers. Conclusions This study yielded the first content valid self-report measure

  1. Accurate thermoelastic tensor and acoustic velocities of NaCl

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marcondes, Michel L., E-mail: michel@if.usp.br; Chemical Engineering and Material Science, University of Minnesota, Minneapolis, 55455; Shukla, Gaurav, E-mail: shukla@physics.umn.edu

    Despite the importance of thermoelastic properties of minerals in geology and geophysics, their measurement at high pressures and temperatures are still challenging. Thus, ab initio calculations are an essential tool for predicting these properties at extreme conditions. Owing to the approximate description of the exchange-correlation energy, approximations used in calculations of vibrational effects, and numerical/methodological approximations, these methods produce systematic deviations. Hybrid schemes combining experimental data and theoretical results have emerged as a way to reconcile available information and offer more reliable predictions at experimentally inaccessible thermodynamics conditions. Here we introduce a method to improve the calculated thermoelastic tensor bymore » using highly accurate thermal equation of state (EoS). The corrective scheme is general, applicable to crystalline solids with any symmetry, and can produce accurate results at conditions where experimental data may not exist. We apply it to rock-salt-type NaCl, a material whose structural properties have been challenging to describe accurately by standard ab initio methods and whose acoustic/seismic properties are important for the gas and oil industry.« less

  2. Accurate L-Band Measurements of the Dielectric Constant of Seawater

    NASA Technical Reports Server (NTRS)

    Lang, R.H.; Utku, C.; Tarkocin, Y.; Vine, D.M. Le

    2007-01-01

    A new temperature controlled microwave cavity system to measure the complex dielectric constant of seawater at 1.413 GHz is discussed. The system is being developed to measure seawater for temperatures from O C to 30 C and salinities from 10 to 40 psu, The paper discusses the construction of the measurement system and initial stability tests.

  3. The importance of accurate measurement of aortic stiffness in patients with chronic kidney disease and end-stage renal disease.

    PubMed

    Adenwalla, Sherna F; Graham-Brown, Matthew P M; Leone, Francesca M T; Burton, James O; McCann, Gerry P

    2017-08-01

    Cardiovascular (CV) disease is the leading cause of death in chronic kidney disease (CKD) and end-stage renal disease (ESRD). A key driver in this pathology is increased aortic stiffness, which is a strong, independent predictor of CV mortality in this population. Aortic stiffening is a potentially modifiable biomarker of CV dysfunction and in risk stratification for patients with CKD and ESRD. Previous work has suggested that therapeutic modification of aortic stiffness may ameliorate CV mortality. Nevertheless, future clinical implementation relies on the ability to accurately and reliably quantify stiffness in renal disease. Pulse wave velocity (PWV) is an indirect measure of stiffness and is the accepted standard for non-invasive assessment of aortic stiffness. It has typically been measured using techniques such as applanation tonometry, which is easy to use but hindered by issues such as the inability to visualize the aorta. Advances in cardiac magnetic resonance imaging now allow direct measurement of stiffness, using aortic distensibility, in addition to PWV. These techniques allow measurement of aortic stiffness locally and are obtainable as part of a comprehensive, multiparametric CV assessment. The evidence cannot yet provide a definitive answer regarding which technique or parameter can be considered superior. This review discusses the advantages and limitations of non-invasive methods that have been used to assess aortic stiffness, the key studies that have assessed aortic stiffness in patients with renal disease and why these tools should be standardized for use in clinical trial work.

  4. The importance of accurate measurement of aortic stiffness in patients with chronic kidney disease and end-stage renal disease

    PubMed Central

    Adenwalla, Sherna F.; Leone, Francesca M.T.; Burton, James O.; McCann, Gerry P.

    2017-01-01

    Abstract Cardiovascular (CV) disease is the leading cause of death in chronic kidney disease (CKD) and end-stage renal disease (ESRD). A key driver in this pathology is increased aortic stiffness, which is a strong, independent predictor of CV mortality in this population. Aortic stiffening is a potentially modifiable biomarker of CV dysfunction and in risk stratification for patients with CKD and ESRD. Previous work has suggested that therapeutic modification of aortic stiffness may ameliorate CV mortality. Nevertheless, future clinical implementation relies on the ability to accurately and reliably quantify stiffness in renal disease. Pulse wave velocity (PWV) is an indirect measure of stiffness and is the accepted standard for non-invasive assessment of aortic stiffness. It has typically been measured using techniques such as applanation tonometry, which is easy to use but hindered by issues such as the inability to visualize the aorta. Advances in cardiac magnetic resonance imaging now allow direct measurement of stiffness, using aortic distensibility, in addition to PWV. These techniques allow measurement of aortic stiffness locally and are obtainable as part of a comprehensive, multiparametric CV assessment. The evidence cannot yet provide a definitive answer regarding which technique or parameter can be considered superior. This review discusses the advantages and limitations of non-invasive methods that have been used to assess aortic stiffness, the key studies that have assessed aortic stiffness in patients with renal disease and why these tools should be standardized for use in clinical trial work. PMID:28852490

  5. Measuring the Complexity of Treatment for Challenging Behavior using the Treatment Intensity Rating Form

    PubMed Central

    Zarcone, Jennifer; Hagopian, Louis; Ninci, Jennifer; McKay, Chloe; Bonner, Andrew; Dillon, Christopher; Hausman, Nicole

    2016-01-01

    Objectives The goal of this study was to develop and evaluate a tool to measure the complexity and intensity of psychotropic medication interventions, behavioral interventions, and issues related to crisis management for challenging behavior using a standardized rating form. Method The Treatment Intensity Rating Form (TIRF) is a 10-item scale with three categories: pharmacological interventions, behavior supports, and protective equipment. In a retrospective review we examined the final treatment recommendations for 74 individuals with self-injurious behavior (SIB) based on psychiatric and behavioral notes and reports. We also compared whether TIRF scores differed across individuals for whom SIB was maintained by social reinforcement (e.g., to access attention or toys/activities, or escape from tasks) versus those for whom SIB was maintained by automatic reinforcement (e.g., occurs independent of social variables, and is presumed to be maintained by sensory reinforcement). Results The TIRF was demonstrated to have strong inter-rater reliability (98%) and appears to have good face validity. As hypothesized, individuals with SIB maintained by automatic reinforcement had significantly more medication trials (p=0.0005) and required more protective equipment than individuals with SIB maintained by social reinforcement (p=0.0002). Antidepressant medication was used more often with individuals with automatically reinforced SIB, although antipsychotics and anticonvulsants were also commonly used across both groups. Conclusion Findings provide initial support for the TIRF’s reliability, and face validity as a measure the level of complexity of medical and behavioral treatment plans - although additional research is needed to fully evaluate its psychometric properties. PMID:27917287

  6. Measuring the Complexity of Treatment for Challenging Behavior using the Treatment Intensity Rating Form.

    PubMed

    Zarcone, Jennifer; Hagopian, Louis; Ninci, Jennifer; McKay, Chloe; Bonner, Andrew; Dillon, Christopher; Hausman, Nicole

    2016-01-01

    The goal of this study was to develop and evaluate a tool to measure the complexity and intensity of psychotropic medication interventions, behavioral interventions, and issues related to crisis management for challenging behavior using a standardized rating form. The Treatment Intensity Rating Form (TIRF) is a 10-item scale with three categories: pharmacological interventions, behavior supports, and protective equipment. In a retrospective review we examined the final treatment recommendations for 74 individuals with self-injurious behavior (SIB) based on psychiatric and behavioral notes and reports. We also compared whether TIRF scores differed across individuals for whom SIB was maintained by social reinforcement (e.g., to access attention or toys/activities, or escape from tasks) versus those for whom SIB was maintained by automatic reinforcement (e.g., occurs independent of social variables, and is presumed to be maintained by sensory reinforcement). The TIRF was demonstrated to have strong inter-rater reliability (98%) and appears to have good face validity. As hypothesized, individuals with SIB maintained by automatic reinforcement had significantly more medication trials (p=0.0005) and required more protective equipment than individuals with SIB maintained by social reinforcement (p=0.0002). Antidepressant medication was used more often with individuals with automatically reinforced SIB, although antipsychotics and anticonvulsants were also commonly used across both groups. Findings provide initial support for the TIRF's reliability, and face validity as a measure the level of complexity of medical and behavioral treatment plans - although additional research is needed to fully evaluate its psychometric properties.

  7. Predicting Aggressive Behavior in Children with the Help of Measures of Implicit and Explicit Aggression

    ERIC Educational Resources Information Center

    Grumm, Mandy; Hein, Sascha; Fingerle, Michael

    2011-01-01

    Aggressive behavior between children in schools is a topic that receives much interest as violence and aggressive behavior cause many maladaptive social outcomes in the school setting. In the current study the Implicit Association Test (IAT) was adapted as a measure of children's implicit aggression, by assessing the association of the self…

  8. Direct and accurate measurement of size dependent wetting behaviors for sessile water droplets

    PubMed Central

    Park, Jimin; Han, Hyung-Seop; Kim, Yu-Chan; Ahn, Jae-Pyeong; Ok, Myoung-Ryul; Lee, Kyung Eun; Lee, Jee-Wook; Cha, Pil-Ryung; Seok, Hyun-Kwang; Jeon, Hojeong

    2015-01-01

    The size-dependent wettability of sessile water droplets is an important matter in wetting science. Although extensive studies have explored this problem, it has been difficult to obtain empirical data for microscale sessile droplets at a wide range of diameters because of the flaws resulting from evaporation and insufficient imaging resolution. Herein, we present the size-dependent quantitative change of wettability by directly visualizing the three phase interfaces of droplets using a cryogenic-focused ion beam milling and SEM-imaging technique. With the fundamental understanding of the formation pathway, evaporation, freezing, and contact angle hysteresis for sessile droplets, microdroplets with diameters spanning more than three orders of magnitude on various metal substrates were examined. Wetting nature can gradually change from hydrophobic at the hundreds-of-microns scale to super-hydrophobic at the sub-μm scale, and a nonlinear relationship between the cosine of the contact angle and contact line curvature in microscale water droplets was demonstrated. We also showed that the wettability could be further tuned in a size-dependent manner by introducing regular heterogeneities to the substrate. PMID:26657208

  9. Examining Convergence of Retrospective and Ecological Momentary Assessment Measures of Negative Affect and Eating Disorder Behaviors

    PubMed Central

    Wonderlich, Joseph A.; Lavender, Jason M.; Wonderlich, Stephen A.; Peterson, Carol B.; Crow, Scott J.; Engel, Scott G.; Le Grange, Daniel; Mitchell, James E.; Crosby, Ross D.

    2017-01-01

    Objective Data gathered via retrospective forms of assessment are subject to various recall biases. Ecological momentary assessment (EMA) is an alternative approach involving repeated momentary assessments within a participant's natural environment, thus reducing recall biases and improving ecological validity. EMA has been used in numerous prior studies examining various constructs of theoretical relevance to eating disorders. Method This investigation includes data from three previously published studies with distinct clinical samples: (a) women with anorexia nervosa (N=118), (b) women with bulimia nervosa (N=133), and (c) obese men and women (N=50; 9 with current binge eating disorder). Each study assessed negative affective states and eating disorder behaviors using traditional retrospective assessments and EMA. Spearman rho correlations were used to evaluate the concordance of retrospective versus EMA measures of affective and/or behavioral constructs in each sample. Bland-Altman plots were also used to further evaluate concordance in the assessment of eating disorder behaviors. Results There was moderate to strong concordance for the measures of negative affective states across all three studies. Moderate to strong concordance was also found for the measures of binge eating and exercise frequency. The strongest evidence of concordance across measurement approaches was found for purging behaviors. Discussion Overall, these preliminary findings support the convergence of retrospective and EMA assessments of both negative affective states and various eating disorder behaviors. Given the advantages and disadvantages associated with each of these assessment approaches, the specific questions being studied in future empirical studies should inform decisions regarding selection of the most appropriate method. PMID:25195932

  10. In Situ Local Measurement of Austenite Mechanical Stability and Transformation Behavior in Third-Generation Advanced High-Strength Steels

    NASA Astrophysics Data System (ADS)

    Abu-Farha, Fadi; Hu, Xiaohua; Sun, Xin; Ren, Yang; Hector, Louis G.; Thomas, Grant; Brown, Tyson W.

    2018-05-01

    Austenite mechanical stability, i.e., retained austenite volume fraction (RAVF) variation with strain, and transformation behavior were investigated for two third-generation advanced high-strength steels (3GAHSS) under quasi-static uniaxial tension: a 1200 grade, two-phase medium Mn (10 wt pct) TRIP steel, and a 980 grade, three-phase TRIP steel produced with a quenching and partitioning heat treatment. The medium Mn (10 wt pct) TRIP steel deforms inhomogeneously via propagative instabilities (Lüders and Portevin Le Châtelier-like bands), while the 980 grade TRIP steel deforms homogenously up to necking. The dramatically different deformation behaviors of these steels required the development of a new in situ experimental technique that couples volumetric synchrotron X-ray diffraction measurement of RAVF with surface strain measurement using stereo digital image correlation over the beam impingement area. Measurement results with the new technique are compared to those from a more conventional approach wherein strains are measured over the entire gage region, while RAVF measurement is the same as that in the new technique. A determination is made as to the appropriateness of the different measurement techniques in measuring the transformation behaviors for steels with homogeneous and inhomogeneous deformation behaviors. Extension of the new in situ technique to the measurement of austenite transformation under different deformation modes and to higher strain rates is discussed.

  11. In Situ Local Measurement of Austenite Mechanical Stability and Transformation Behavior in Third-Generation Advanced High-Strength Steels

    NASA Astrophysics Data System (ADS)

    Abu-Farha, Fadi; Hu, Xiaohua; Sun, Xin; Ren, Yang; Hector, Louis G.; Thomas, Grant; Brown, Tyson W.

    2018-07-01

    Austenite mechanical stability, i.e., retained austenite volume fraction (RAVF) variation with strain, and transformation behavior were investigated for two third-generation advanced high-strength steels (3GAHSS) under quasi-static uniaxial tension: a 1200 grade, two-phase medium Mn (10 wt pct) TRIP steel, and a 980 grade, three-phase TRIP steel produced with a quenching and partitioning heat treatment. The medium Mn (10 wt pct) TRIP steel deforms inhomogeneously via propagative instabilities (Lüders and Portevin Le Châtelier-like bands), while the 980 grade TRIP steel deforms homogenously up to necking. The dramatically different deformation behaviors of these steels required the development of a new in situ experimental technique that couples volumetric synchrotron X-ray diffraction measurement of RAVF with surface strain measurement using stereo digital image correlation over the beam impingement area. Measurement results with the new technique are compared to those from a more conventional approach wherein strains are measured over the entire gage region, while RAVF measurement is the same as that in the new technique. A determination is made as to the appropriateness of the different measurement techniques in measuring the transformation behaviors for steels with homogeneous and inhomogeneous deformation behaviors. Extension of the new in situ technique to the measurement of austenite transformation under different deformation modes and to higher strain rates is discussed.

  12. The use of operant technology to measure behavioral priorities in captive animals.

    PubMed

    Cooper, J J; Mason, G J

    2001-08-01

    Addressing the behavioral priorities of captive animals and the development of practical, objective measures of the value of environmental resources is a principal objective of animal welfare science. In theory, consumer demand approaches derived from human microeconomics should provide valid measures of the value of environmental resources. In practice, however, a number of empirical and theoretical problems have rendered these measures difficult to interpret in studies with animals. A common approach has been to impose a cost on access to resources and to use time with each resource as a measure of consumption to construct demand curves. This can be recorded easily by automatic means, but in a number of studies, it has been found that animals compensate for increased cost of access with longer visit time. Furthermore, direct observation of the test animals' behavior has shown that resource interaction is more intense once the animals have overcome higher costs. As a consequence, measures based on time with the resource may underestimate resource consumption at higher access costs, and demand curves derived from these measures may not be a true reflection of the value of different resources. An alternative approach to demand curves is reservation price, which is the maximum price individual animals are prepared to pay to gain access to resources. In studies using this approach, farmed mink (Mustela vison) paid higher prices for food and swimming water than for resources such as tunnels, water bowls, pet toys, and empty compartments. This indicates that the mink placed a higher value on food and swimming water than on other resources.

  13. Knowing what the brain is seeing in three dimensions: A novel, noninvasive, sensitive, accurate, and low-noise technique for measuring ocular torsion.

    PubMed

    Otero-Millan, Jorge; Roberts, Dale C; Lasker, Adrian; Zee, David S; Kheradmand, Amir

    2015-01-01

    Torsional eye movements are rotations of the eye around the line of sight. Measuring torsion is essential to understanding how the brain controls eye position and how it creates a veridical perception of object orientation in three dimensions. Torsion is also important for diagnosis of many vestibular, neurological, and ophthalmological disorders. Currently, there are multiple devices and methods that produce reliable measurements of horizontal and vertical eye movements. Measuring torsion, however, noninvasively and reliably has been a longstanding challenge, with previous methods lacking real-time capabilities or suffering from intrusive artifacts. We propose a novel method for measuring eye movements in three dimensions using modern computer vision software (OpenCV) and concepts of iris recognition. To measure torsion, we use template matching of the entire iris and automatically account for occlusion of the iris and pupil by the eyelids. The current setup operates binocularly at 100 Hz with noise <0.1° and is accurate within 20° of gaze to the left, to the right, and up and 10° of gaze down. This new method can be widely applicable and fill a gap in many scientific and clinical disciplines.

  14. Knowing what the brain is seeing in three dimensions: A novel, noninvasive, sensitive, accurate, and low-noise technique for measuring ocular torsion

    PubMed Central

    Otero-Millan, Jorge; Roberts, Dale C.; Lasker, Adrian; Zee, David S.; Kheradmand, Amir

    2015-01-01

    Torsional eye movements are rotations of the eye around the line of sight. Measuring torsion is essential to understanding how the brain controls eye position and how it creates a veridical perception of object orientation in three dimensions. Torsion is also important for diagnosis of many vestibular, neurological, and ophthalmological disorders. Currently, there are multiple devices and methods that produce reliable measurements of horizontal and vertical eye movements. Measuring torsion, however, noninvasively and reliably has been a longstanding challenge, with previous methods lacking real-time capabilities or suffering from intrusive artifacts. We propose a novel method for measuring eye movements in three dimensions using modern computer vision software (OpenCV) and concepts of iris recognition. To measure torsion, we use template matching of the entire iris and automatically account for occlusion of the iris and pupil by the eyelids. The current setup operates binocularly at 100 Hz with noise <0.1° and is accurate within 20° of gaze to the left, to the right, and up and 10° of gaze down. This new method can be widely applicable and fill a gap in many scientific and clinical disciplines. PMID:26587699

  15. Health behavior in persons with spinal cord injury: development and initial validation of an outcome measure.

    PubMed

    Pruitt, S D; Wahlgren, D R; Epping-Jordan, J E; Rossi, A L

    1998-10-01

    To describe the development and initial psychometric properties of a new outcome measure for health behaviors that delay or prevent secondary impairments associated with spinal cord injury (SCI). Persons with SCI were surveyed during routine annual physical evaluations. Veterans Affairs Medical Center Spinal Cord Injury Unit, which specializes in primary care for persons with SCI. Forty-nine persons with SCI, aged 19-73 years, 1-50 years post-SCI. The newly developed Spinal Cord Injury Lifestyle Scale (SCILS). Internal consistency is high (alpha = 0.81). Correlations between clinicians' ratings of participants' health behavior and the new SCILS provide preliminary support for construct validity. The SCILS is a brief, self-report measure of health-related behavior in persons with SCI. It is a promising new outcome measure to evaluate the effectiveness of clinical and educational efforts for health maintenance and prevention of secondary impairments associated with SCI.

  16. Measurement invariance of an instrument assessing sustainability of school-based universal behavior practices.

    PubMed

    Mercer, Sterett H; McIntosh, Kent; Strickland-Cohen, M Kathleen; Horner, Robert H

    2014-06-01

    The purpose of the study was to examine the extent to which the School-Wide Universal Behavior Sustainability Index: School Teams (SUBSIST; McIntosh, Doolittle, Vincent, Horner, & Ervin, 2009), a measure of school and district contextual factors that promote the sustainability of school practices, demonstrated measurement invariance across groups of schools that differed in length of time implementing school-wide Positive Behavioral Interventions and Supports (PBIS; Sugai & Horner, 2009), student ethnic composition, and student socioeconomic status (SES). School PBIS team members and district coaches representing 860 schools in 14 U.S. states completed the SUBSIST. Findings supported strong measurement invariance, for all items except 1, of a model with two school-level factors (School Priority and Team Use of Data) and 2 district-level factors (District Priority and Capacity Building) across groups of schools at initial implementation, institutionalization, and sustainability phases of PBIS implementation. Schools in the sustainability phase were rated significantly higher on School Priority and Team Use of Data than schools in initial implementation. Strong measurement invariance held across groups of schools that differed in student ethnicity and SES. The findings regarding measurement invariance are important for future longitudinal investigations of factors that may promote the sustained implementation of school practices. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  17. Media Exposure in Low-Income Preschool-Aged Children Is Associated with Multiple Measures of Self-Regulatory Behavior.

    PubMed

    Munzer, Tiffany G; Miller, Alison L; Peterson, Karen E; Brophy-Herb, Holly E; Horodynski, Mildred A; Contreras, Dawn; Sturza, Julie; Lumeng, Julie C; Radesky, Jenny

    2018-05-01

    Excessive screen media exposure in childhood is associated with parent-reported self-regulation difficulties. No studies have used laboratory-based or teacher-reported measures of child self-regulatory behaviors. This study examines cross-sectional associations between preschooler screen media exposure and multiple measures of self-regulatory behaviors. Preintervention data were used from 541 preschoolers in the Growing Healthy study, an obesity prevention trial (2011-2015). Screen media exposure was measured by daily screen media exposure (hr/d), television (TV) in the bedroom, frequency of background TV, and TV with meals (1 = rarely/never, 4 = frequently). Child self-regulatory behaviors were measured by the following: child ability to delay gratification, a standardized waiting paradigm; teacher-reported Social Competence and Behavior Evaluation; and parent-reported difficult temperament on the Child Behavior Questionnaire (CBQ). Multivariate regression analyses modeled screen media exposure predicting each self-regulatory measure, adjusting for child age, sex, parent age, education, marital status, income-to-needs ratio, number of adults in household, parent depressive symptoms, and sensitivity. Children were aged 4.1 years (SD = 0.5), parents were aged 29.6 years (SD = 6.8), 48% had high school education or less, and 67% were married. Daily screen media exposure and background TV were associated with weaker observed self-regulation (β: -10.30 seconds for each hr/d media, -12.63 seconds for 1-point increase, respectively). Background TV and TV with meals were associated with greater parent-reported difficult temperament (β: 0.04 and 0.05 CBQ, respectively, for 1-point increase). Greater screen media exposure had small but significant associations with weaker observed and parent-reported, but not teacher-reported, self-regulatory behaviors. Longitudinal studies are needed to determine the directionality of associations.

  18. Inter-rater reliability for movement pattern analysis (MPA): measuring patterning of behaviors versus discrete behavior counts as indicators of decision-making style.

    PubMed

    Connors, Brenda L; Rende, Richard; Colton, Timothy J

    2014-01-01

    The unique yield of collecting observational data on human movement has received increasing attention in a number of domains, including the study of decision-making style. As such, interest has grown in the nuances of core methodological issues, including the best ways of assessing inter-rater reliability. In this paper we focus on one key topic - the distinction between establishing reliability for the patterning of behaviors as opposed to the computation of raw counts - and suggest that reliability for each be compared empirically rather than determined a priori. We illustrate by assessing inter-rater reliability for key outcome measures derived from movement pattern analysis (MPA), an observational methodology that records body movements as indicators of decision-making style with demonstrated predictive validity. While reliability ranged from moderate to good for raw counts of behaviors reflecting each of two Overall Factors generated within MPA (Assertion and Perspective), inter-rater reliability for patterning (proportional indicators of each factor) was significantly higher and excellent (ICC = 0.89). Furthermore, patterning, as compared to raw counts, provided better prediction of observable decision-making process assessed in the laboratory. These analyses support the utility of using an empirical approach to inform the consideration of measuring patterning versus discrete behavioral counts of behaviors when determining inter-rater reliability of observable behavior. They also speak to the substantial reliability that may be achieved via application of theoretically grounded observational systems such as MPA that reveal thinking and action motivations via visible movement patterns.

  19. Teacher Implementation of Trial-Based Functional Analysis and Differential Reinforcement of Alternative Behavior for Students with Challenging Behavior

    ERIC Educational Resources Information Center

    Flynn, Susan D.; Lo, Ya-yu

    2016-01-01

    The purpose of this study was to examine the effects of a training package on three middle school special education teachers' accurate implementation of trial-based functional analysis (TBFA) and differential reinforcement of alternative behavior (DRA) with their students with autism spectrum disorders or emotional and behavioral disorders in the…

  20. Precipitation Measurements from Space: The Global Precipitation Measurement Mission

    NASA Technical Reports Server (NTRS)

    Hou, Arthur Y.

    2007-01-01

    Water is fundamental to the life on Earth and its phase transition between the gaseous, liquid, and solid states dominates the behavior of the weather/climate/ecological system. Precipitation, which converts atmospheric water vapor into rain and snow, is central to the global water cycle. It regulates the global energy balance through interactions with clouds and water vapor (the primary greenhouse gas), and also shapes global winds and dynamic transport through latent heat release. Surface precipitation affects soil moisture, ocean salinity, and land hydrology, thus linking fast atmospheric processes to the slower components of the climate system. Precipitation is also the primary source of freshwater in the world, which is facing an emerging freshwater crisis in many regions. Accurate and timely knowledge of global precipitation is essential for understanding the behavior of the global water cycle, improving freshwater management, and advancing predictive capabilities of high-impact weather events such as hurricanes, floods, droughts, and landslides. With limited rainfall networks on land and the impracticality of making extensive rainfall measurements over oceans, a comprehensive description of the space and time variability of global precipitation can only be achieved from the vantage point of space. This presentation will examine current capabilities in space-borne rainfall measurements, highlight scientific and practical benefits derived from these observations to date, and provide an overview of the multi-national Global Precipitation Measurement (GPM) Mission scheduled to bc launched in the early next decade.