Sample records for acetabular fractures treated

  1. [Effects of Surgically Treated Pelvic Ring and Acetabular Fractures on Postural Control].

    PubMed

    Lang, P; Schnegelberger, A; Riesner, H-J; Stuby, F; Friemert, B; Palm, H-G

    2016-04-01

    The aim of surgical treatment of pelvic ring and acetabular fractures is to allow rapid mobilisation of patients in order to restore stance and gait stability (postural control), as this significantly correlates with a positive outcome. The regulation of postural stability is mainly controlled by transmission of proprioceptive stimuli. In addition, the pelvis serves as a connection between the legs and the spine and thus is also of great importance for mechanical stabilisation. It remains unclear whether surgical treatment of pelvic ring and acetabular fractures affects the regulation of postural control. Therefore, the aim of this study was to examine the impact of surgically treated pelvic ring and acetabular fractures on postural stability by means of computerised dynamic posturography (CDP) after a mean of 35 months and to compare the results with a healthy control group. A retrospective case control study of 38 patients with surgically treated pelvic ring and acetabular fractures and 38 healthy volunteers was carried out using CDP. The average time of follow-up was 35 (12-78) months. The most important outcome parameter in this investigation was the overall stability index (OSI). Hip joint mobility, the health-related quality of life (SF-12) and pain were supplementary outcome parameters. It was found that surgically treated pelvic ring and acetabular fractures had no influence on postural stability. The OSI was 2.1 ° in the patient group and 1.9 ° in the control group. There was no significant difference between the groups in hip joint mobility. A total of 52 % of patients showed no or only mild pain. Mean health-related quality of life was the same as in the total population. Surgically treated pelvic ring and acetabular fractures do not lead to deterioration in postural control in the mid term. This is of high prognostic importance for rapid mobilisation of the patients. Therefore no increase in the risk of falling is expected after successfully

  2. Comparative study of comminuted posterior acetabular wall fracture treated with the Acetabular Tridimensional Memory Fixation System.

    PubMed

    Zhang, Yuntong; Zhao, Xue; Tang, Yang; Zhang, Chuncai; Xu, Shuogui; Xie, Yang

    2014-04-01

    Posterior wall fractures are one of the most common acetabular fractures. However, only 30% of these fractures involve a single large fragment, and comminuted acetabular posterior wall fractures pose a particular surgical challenge. The purpose of this study was to compare outcomes between patients who received fixation for comminuted posterior wall fracture using the Acetabular Tridimensional Memory Fixation System (ATMFS) and patients who underwent fixation with conventional screws and buttress plates (Plates group). Between April 2003 and May 2007, 196 consecutive patients who sustained a comminuted posterior wall fracture of acetabulum were treated with ATMFS or conventional screws and buttress plates. Operative time, fluoroscopy time, blood loss, and any intra-operative complications were recorded. Plain AP and lateral radiographs were obtained at all visits (Matta's criteria). Modified Merle d' Aubigne-Postel score, and Mos SF-36 score were compared between groups. Fifty patients were included in the analysis with 26 in the ATMFS group and 24 in the Plates group. The mean follow-up time was 57.5 months, ranging from 31 to 69 months. All patients had fully healed fractures at the final follow-up. There was no difference in clinical outcomes or radiological evaluations between groups. Patients with comminuted posterior wall fractures of the acetabulum treated with the ATMFS or conventional screws and buttress plate techniques achieve a good surgical result. Both techniques are safe, reliable, and practical. Use of the ATMFS technique may reduce blood loss and improve rigid support to marginal bone impaction. The use ATMFS may need additional support when fractures involve the superior roof. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Reduced survival for uncemented compared to cemented total hip arthroplasty after operatively treated acetabular fractures.

    PubMed

    Clarke-Jenssen, John; Westberg, Marianne; Røise, Olav; Storeggen, Stein Arne Øvre; Bere, Tone; Silberg, Ingunn; Madsen, Jan Erik

    2017-11-01

    Post traumatic arthritis and avascular necrosis of the femoral head are common complications after operatively treated acetabular fractures. This may cause severe disabilities for the patient, necessitating a total hip arthroplasty. Even though an arthroplasty may provide good symptomatic relief, the long-term results are more uncertain and no consensus exists according to preferred prosthetic designs. With this cohort study, we aimed to investigate the medium to long term arthroplasty survival and clinical results of total hip arthroplasty after operatively treated acetabular fractures. We included 52 patients treated with a secondary total hip arthroplasty at a median of 2.4 (0.1-14.1) years after an operatively treated acetabular fracture. The median age was 54 (11-82) years. Cemented arthroplasty was used for 33 patients, 10 patients had an uncemented arthroplasty and 9 patients received a hybrid arthroplasty. Average follow up was 8.0 (SD 5.0) years. Ten-year revision free arthroplasty survival was 79%. Uncemented arthroplasties had a significantly worse 10-year survival of 57%. Arthroplasties performed at a centre without a pelvic fracture service also had a significantly worse 10-years survival of 51%. Cox regression showed similar results with an 8-fold increase in risk of revision for both uncemented arthroplasties and operations performed at a non-pelvic trauma centre. Total hip arthroplasty secondary to an operatively treated acetabular fracture provides good symptomatic relief. These patients are, however, complex cases and are probably best treated at specialist centres with both pelvic trauma surgeons and arthroplasty surgeons proficient in complex revisions present. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Controversies in Treatment of Acetabular Fracture

    PubMed Central

    Grubor, Predrag; Krupic, Ferid; Biscevic, Mirza; Grubor, Milan

    2015-01-01

    Introduction: Acetabular fractures treatment represents a great controversy, challenge and dilemma for an orthopedic surgeon. Aim: The aim of the paper was to present the results of treatment of 96 acetabular fractures in the Clinic of Traumatology Banja Luka, in the period from 2003 to 2013, as well as to raise awareness regarding the controversy in the methods of choice in treating acetabulum fractures. Material and methods: The series consists of 96 patients, 82 males and 14 females, average age 40.5 years. Traffic trauma was the cause of fractures in 79 patients (85%), and in 17 patients (15%) fractures occurred due to falls from height. Polytrauma was present in 31 patients (32%). According to the classification of Judet and Letournel, representation of acetabular fractures was as follows: posterior wall in 32 patients, posterior column in 28, anterior wall in 4, anterior column in 2, transverse fractures in 8, posterior wall and posterior column in 10, anterior and posterior wall in 6, both- column in 4 and transversal fracture and posterior wall in 2 patients. 14 patients were treated with traction, that is, 6 patients with femoral traction and 8 patients with both lateral and femoral traction. 82 patients (86.4%) were surgically treated. Kocher-Langenbeck approach was applied in the treatment of 78 patients. In two patients from the Kocher-Langenbeck’s approach, the Ollier’s approach had to be applied as well. Two acetabular were primarily treated with Ollier’s approach. Extended Smith- Peterson’s approach was applied 4 times, and Emile Letournel’s (ilioinguinal) approach 14 times. Results: Functional outcome (after follow-up of 18 months), according to the Harris hip score of surgical treatment in 82 patients, was as follows: good 46 (56%), satisfactory 32 (39%) and poor 4 (5%). Results of acetabulum fractures treated with traction were: good 8 (57%), satisfactory 4 (28%) and poor 2 (15%). According to the Brook’s classification of heterotopic

  5. Acetabular fractures: anatomic and clinical considerations.

    PubMed

    Lawrence, David A; Menn, Kirsten; Baumgaertner, Michael; Haims, Andrew H

    2013-09-01

    Classifying acetabular fractures can be an intimidating topic. However, it is helpful to remember that there are only three basic types of acetabular fractures: column fractures, transverse fractures, and wall fractures. Within this framework, acetabular fractures are classified into two broad categories: elementary or associated fractures. We will review the osseous anatomy of the pelvis and provide systematic approaches for reviewing both radiographs and CT scans to effectively evaluate the acetabulum. Although acetabular fracture classification may seem intimidating, the descriptions and distinctions discussed and shown in this article hopefully make the topic simpler to understand. Approach the task by recalling that there are only three basic types of acetabular fractures: column fractures (coronally oriented on CT images), transverse fractures (sagittally oriented on CT images), and wall fractures (obliquely oriented on CT images). We have provided systematic approaches for reviewing both conventional radiographs and CT scans to effectively assess the acetabulum. The clinical implications of the different fracture patterns have also been reviewed because it is critically important to include pertinent information for our clinical colleagues to provide the most efficient and timely clinical care.

  6. [Application of three-dimensional printing personalized acetabular wing-plate in treatment of complex acetabular fractures via lateral-rectus approach].

    PubMed

    Mai, J G; Gu, C; Lin, X Z; Li, T; Huang, W Q; Wang, H; Tan, X Y; Lin, H; Wang, Y M; Yang, Y Q; Jin, D D; Fan, S C

    2017-03-01

    Objective: To investigate reduction and fixation of complex acetabular fractures using three-dimensional (3D) printing technique and personalized acetabular wing-plate via lateral-rectus approach. Methods: From March to July 2016, 8 patients with complex acetabular fractures were surgically managed through 3D printing personalized acetabular wing-plate via lateral-rectus approach at Department of Orthopedics, the Third Affiliated Hospital of Southern Medical University. There were 4 male patients and 4 female patients, with an average age of 57 years (ranging from 31 to 76 years). According to Letournel-Judet classification, there were 2 anterior+ posterior hemitransverse fractures and 6 both-column fractures, without posterior wall fracture or contralateral pelvic fracture. The CT data files of acetabular fracture were imported into the computer and 3D printing technique was used to print the fractures models after reduction by digital orthopedic technique. The acetabular wing-plate was designed and printed with titanium. All fractures were treated via the lateral-rectus approach in a horizontal position after general anesthesia. The anterior column and the quadrilateral surface fractures were fixed by 3D printing personalized acetabular wing-plate, and the posterior column fractures were reduction and fixed by antegrade lag screws under direct vision. Results: All the 8 cases underwent the operation successfully. Postoperative X-ray and CT examination showed excellent or good reduction of anterior and posterior column, without any operation complications. Only 1 case with 75 years old was found screw loosening in the pubic bone with osteoporosis after 1 month's follow-up, who didn't accept any treatment because the patient didn't feel discomfort. According to the Matta radiological evaluation, the reduction of the acetabular fracture was rated as excellent in 3 cases, good in 4 cases and fair in 1 case. All patients were followed up for 3 to 6 months and all

  7. Combat-related acetabular fractures: Outcomes of open versus closed injuries.

    PubMed

    Purcell, Richard L; Donohue, Michael A; Saxena, Sameer K; Gordon, Wade T; Lewandowski, Louis L

    2018-02-01

    Since the onset of the Global War on Terror close to 50,000 United States service members have been injured in combat, many of these injuries would have previously been fatal. Among these injuries, open acetabular fractures are at an increased number due to the high percentage of penetrating injuries such as high velocity gunshot wounds and blast injuries. These injuries lead to a greater degree of contamination, and more severe associated injuries. There is a significantly smaller proportion of the classic blunt trauma mechanism typically seen in civilian trauma. We performed a retrospective review of the Department of Defense Trauma Registry into which all US combat-injured patients are enrolled, as well as reviewed local patient medical records, and radiologic studies from March 2003 to April 2012. Eighty seven (87) acetabular fractures were identified with 32 classified as open fractures. Information regarding mechanism of injury, fracture pattern, transfusion requirements, Injury Severity Score (ISS), and presence of lower extremity amputations was analyzed. The mechanism of injury was an explosive device in 59% (n=19) of patients with an open acetabular fracture; the remaining 40% (n=13) were secondary to ballistic injury. In contrast, in the closed acetabular fracture cohort 38% (21/55) of fractures were due to explosive devices, and all remaining (n=34) were secondary to blunt trauma such as falls, motor vehicle collisions, or aircraft crashes. Patients with open acetabular fractures required a median of 17units of PRBC within the first 24h after injury. The mean ISS was 32 in the open group compared with 22 in the closed group (p=0.003). In the open fracture group nine patients (28%) sustained bilateral lower extremity amputations, and 10 patients (31%) ultimately underwent a hip disarticulation or hemi-pelvectomy as their final amputation level. Open acetabular fractures represent a significant challenge in the management of combat-related injuries. High

  8. A Novel Approach for Treatment of Acetabular Fractures

    PubMed Central

    Xue, Zichao; Qin, Hui; Ding, Haoliang; An, Zhiquan

    2016-01-01

    Background There is no single approach that provides adequate exposure for treatment of all types of acetabular fractures. We describe our experience with an easier, relatively less invasive pubic symphysis approach (PSA) for the treatment of acetabular fractures. Material/Methods Between March 2011 and March 2012, fifteen patients with acetabular fracture underwent surgery using the PSA technique. Fracture reduction and treatment outcomes were assessed by clinical and radiological examination. Operation time, intraoperative blood loss and postoperative complications were documented. Results Mean operative time was 222±78 minutes. Average blood loss was 993±361 mL. Anatomical reduction was achieved in all patients. Minimum follow-up period was 31 months. Postoperative hypoesthesia in the area of innervation of the lateral femoral cutaneous nerve was reported in one patient, with spontaneous recovery at one month after surgery. No complications were reported during the follow-up period. At the most recent follow up, clinical outcomes were graded as “excellent” in six patients, “good” in eight patients and “fair” in one patient based on the modified Merle d’Aubigné-Postel score. Conclusions PSA appears to be a timesaving and safe approach for treatment of acetabular fractures that affords good visual access and allows for excellent fracture reduction. Our preliminary results revealed a much lower incidence of complications than traditional approaches, suggesting PSA is an alternative for treatment of acetabular fractures. PMID:27734825

  9. Safe surgical technique for associated acetabular fractures

    PubMed Central

    2013-01-01

    Associated acetabular fractures are challenging injuries to manage. The complex surgical approaches and the technical difficulty in achieving anatomical reduction imply that the learning curve to achieve high-quality care of patients with such challenging injuries is extremely steep. This first article in the Journal’s “Safe Surgical Technique” section presents the standard surgical care, in conjunction with intraoperative tips and tricks, for the safe management of all subgroups of associated acetabular fractures. PMID:23414782

  10. Computed tomography image-guided surgery in complex acetabular fractures.

    PubMed

    Brown, G A; Willis, M C; Firoozbakhsh, K; Barmada, A; Tessman, C L; Montgomery, A

    2000-01-01

    Eleven complex acetabular fractures in 10 patients were treated by open reduction with internal fixation incorporating computed tomography image guided software intraoperatively. Each of the implants placed under image guidance was found to be accurate and without penetration of the pelvis or joint space. The setup time for the system was minimal. Accuracy in the range of 1 mm was found when registration was precise (eight cases) and was in the range of 3.5 mm when registration was only approximate (three cases). Added benefits included reduced intraoperative fluoroscopic time, less need for more extensive dissection, and obviation of additional surgical approaches in some cases. Compared with a series of similar fractures treated before this image guided series, the reduction in operative time was significant. For patients with complex anterior and posterior combined fractures, the average operation times with and without application of three-dimensional imaging technique were, respectively, 5 hours 15 minutes and 6 hours 14 minutes, revealing 16% less operative time for those who had surgery using image guidance. In the single column fracture group, the operation time for those with three-dimensional imaging application, was 2 hours 58 minutes and for those with traditional surgery, 3 hours 42 minutes, indicating 20% less operative time for those with imaging modality. Intraoperative computed tomography guided imagery was found to be an accurate and suitable method for use in the operative treatment of complex acetabular fractures with substantial displacement.

  11. Variation in Treatment of Displaced Geriatric Acetabular Fractures Among 15 Level-I Trauma Centers.

    PubMed

    Manson, Theodore T; Reider, Lisa; OʼToole, Robert V; Scharfstein, Daniel O; Tornetta, Paul; Gary, Joshua L

    2016-09-01

    To document the initial treatment of displaced acetabular fractures among older adults across multiple trauma centers and to investigate the factors that influence the decision to operate and the choice of operative procedure [open reduction internal fixation (ORIF) vs. total hip arthroplasty (THA)]. Retrospective observational study. Fifteen US level-I trauma centers participating in the Major Extremity Trauma Research Consortium. Overall, 269 patients aged 60 years or older admitted for the treatment of a displaced acetabular fracture. None. Treatment. Sixty percent of fractures (n = 162) were treated operatively. Younger age (<80 years), injury from high-energy mechanism, fractures with femoral head impaction, and fractures without hip congruency were significantly associated with receiving operative treatment (P < 0.05). Significant site variation in operative versus nonoperative treatment occurred even after accounting for these factors (P = 0.0044). Among operatively treated patients, 88% (n = 142) received ORIF and 12% (n = 20) received THA as the initial treatment. Women were more likely to be treated with initial THA compared with men; of the known risk factors for poor outcomes with ORIF (ie, dome or roof impaction, femoral head impaction, or posterior wall involvement), only dome impaction was significantly associated with receiving initial THA (P < 0.05). Currently, no treatment guidelines exist for acetabular fractures in older adults, which likely explains the significant site variation in operative versus nonoperative treatment. This study identifies patient and injury factors that drive treatment decisions, which will be important in planning and designing future trials needed to determine the best treatment for these fractures.

  12. Increased Mortality in Elderly Patients with Sarcopenia and Acetabular Fractures.

    PubMed

    Deren, Matthew E; Babu, Jacob; Cohen, Eric M; Machan, Jason; Born, Christopher T; Hayda, Roman

    2017-02-01

    Sarcopenia is a condition of clinically relevant loss of muscle mass and function. Acetabular fractures in elderly patients are common and difficult to treat. This study aimed to determine if sarcopenia is common in elderly patients with acetabular fractures and correlates with lower-energy mechanisms of injury, higher rates of complications, and higher mortality than patients with normal muscle mass. The Rhode Island Hospital Trauma Database was queried for patients who were ≥60 years of age from 2005 to 2014 using the International Classification of Diseases, Ninth Revision, code for closed acetabular fracture, 808.0. Charts were retrospectively reviewed for demographic data, operative intervention, mechanism of injury, mortality, comorbidities, and other factors. Computed tomography (CT) was used to determine the muscle cross-sectional area and to calculate the skeletal muscle index. The database revealed 192 patients coded for acetabular fracture; of these, 181 were correctly diagnosed. Ninety-nine patients had recorded body mass index (BMI) and adequate CT scans to measure the skeletal muscle index. Forty-two patients (42.4%) had sarcopenia, and 57 patients (57.6%) did not have sarcopenia. There were no significant differences in demographic characteristics between the groups with the exception of BMI and sex. BMI was higher in patients who did not have sarcopenia (31.7 kg/m) than it was in patients with sarcopenia (23.6 kg/m) (p < 0.001). Male sex was significantly greater (p = 0.0104) in patients with sarcopenia at 76.2% (32 of 42 patients) than in patients without sarcopenia at 50.9% (29 of 57 patients). Fractures in patients without sarcopenia were associated with a higher-energy mechanism of injury in 78.9% of cases compared with 52.4% of cases of patients with sarcopenia (p = 0.005). Sarcopenia was significantly associated (p = 0.0419) with increased 1-year mortality (28.6%) compared with the absence of sarcopenia (12.3%). This association was even

  13. Early Versus Late Weight-Bearing Protocols for Surgically Managed Posterior Wall Acetabular Fractures.

    PubMed

    Heare, Austin; Kramer, Nicholas; Salib, Christopher; Mauffrey, Cyril

    2017-07-01

    Despite overall improved outcomes with open reduction and internal fixation of acetabular fractures, posterior wall fractures show disproportionately poor results. The effect of weight bearing on outcomes of fracture management has been investigated in many lower extremity fractures, but evidence-based recommendations in posterior wall acetabular fractures are lacking. The authors systematically reviewed the current literature to determine if a difference in outcome exists between early and late postoperative weight-bearing protocols for surgically managed posterior wall acetabular fractures. PubMed and MEDLINE were searched for posterior wall acetabular fracture studies that included weight-bearing protocols and Merle d'Aubigné functional scores. Twelve studies were identified. Each study was classified as either early or late weight bearing. Early weight bearing was defined as full, unrestricted weight bearing at or before 12 weeks postoperatively. Late weight bearing was defined as restricted weight bearing for greater than 12 weeks postoperatively. The 2 categories were then compared by functional score using a 2-tailed t test and by complication rate using chi-square analysis. Six studies (152 fractures) were placed in the early weight-bearing category. Six studies (302 fractures) were placed in the late weight-bearing category. No significant difference in Merle d'Aubigné functional scores was found between the 2 groups. No difference was found regarding heterotopic ossification, avascular necrosis, superficial infections, total infections, or osteoarthritis. This systematic review found no difference in functional outcome scores or complication rates between early and late weight-bearing protocols for surgically treated posterior wall fractures. [Orthopedics. 2017: 40(4):e652-e657.]. Copyright 2017, SLACK Incorporated.

  14. Atypical anterior wall fracture of the acetabulum: case series of anterior acetabular rim fracture without involvement of the pelvic brim.

    PubMed

    Lenarz, Christopher J; Moed, Berton R

    2007-09-01

    The purpose of this study was to describe a form of anterior wall acetabular fracture, which has been inadequately defined in the literature. Retrospective analysis of consecutive patients. Level 1 trauma center. A retrospective analysis of consecutive acetabulum patients treated by a single surgeon between 1999 and 2005 identified 6 patients with a form of anterior wall fracture without involvement of the pelvic brim. All fractures were treated operatively. Open reduction and internal fixation through an anterior surgical approach. Final radiographic appearance and modified Merle d'Aubigne score. All 6 cases demonstrated characteristics of an atypical fracture of the anterior wall, involving the anterior rim of the acetabulum similar in nature to those described for the posterior wall, rather than the standard anterior wall fracture type described by Letournel. Of the 6 cases that were identified, 5 had follow-up 1 year or greater with a mean modified Merle d'Aubigne Score of 17 (range: 17-18). A form of anterior wall acetabular fracture exists, which involves the anterior acetabular rim without involvement of the pelvic brim. It can occur in young patients with high-energy mechanisms of injury, as well as in the elderly with low-energy trauma. With appropriate surgical management, using a modified Smith-Peterson approach, good to excellent clinical outcomes should be expected.

  15. Computer-assisted virtual preoperative planning in orthopedic surgery for acetabular fractures based on actual computed tomography data.

    PubMed

    Wang, Guang-Ye; Huang, Wen-Jun; Song, Qi; Qin, Yun-Tian; Liang, Jin-Feng

    2016-12-01

    Acetabular fractures have always been very challenging for orthopedic surgeons; therefore, appropriate preoperative evaluation and planning are particularly important. This study aimed to explore the application methods and clinical value of preoperative computer simulation (PCS) in treating pelvic and acetabular fractures. Spiral computed tomography (CT) was performed on 13 patients with pelvic and acetabular fractures, and Digital Imaging and Communications in Medicine (DICOM) data were then input into Mimics software to reconstruct three-dimensional (3D) models of actual pelvic and acetabular fractures for preoperative simulative reduction and fixation, and to simulate each surgical procedure. The times needed for virtual surgical modeling and reduction and fixation were also recorded. The average fracture-modeling time was 45 min (30-70 min), and the average time for bone reduction and fixation was 28 min (16-45 min). Among the surgical approaches planned for these 13 patients, 12 were finally adopted; 12 cases used the simulated surgical fixation, and only 1 case used a partial planned fixation method. PCS can provide accurate surgical plans and data support for actual surgeries.

  16. Intraoperative CT in the assessment of posterior wall acetabular fracture stability.

    PubMed

    Cunningham, Brian; Jackson, Kelly; Ortega, Gil

    2014-04-01

    Posterior wall acetabular fractures that involve 10% to 40% of the posterior wall may or may not require an open reduction and internal fixation. Dynamic stress examination of the acetabular fracture under fluoroscopy has been used as an intraoperative method to assess joint stability. The aim of this study was to demonstrate the value of intraoperative ISO computed tomography (CT) examination using the Siemens ISO-C imaging system (Siemens Corp, Malvern, Pennsylvania) in the assessment of posterior wall acetabular fracture stability during stress examination under anesthesia. In 5 posterior wall acetabular fractures, standard fluoroscopic images (including anteroposterior pelvis and Judet radiographs) with dynamic stress examinations were compared with the ISO-C CT imaging system to assess posterior wall fracture stability during stress examination. After review of standard intraoperative fluoroscopic images under dynamic stress examination, all 5 cases appeared to demonstrate posterior wall stability; however, when the intraoperative images from the ISO-C CT imaging system demonstrated that 1 case showed fracture instability of the posterior wall segment during stress examination, open reduction and internal fixation was performed. The use of intraoperative ISO CT imaging has shown an initial improvement in the surgeon's ability to assess the intraoperative stability of posterior wall acetabular fractures during stress examination when compared with standard fluoroscopic images. Copyright 2014, SLACK Incorporated.

  17. Managing acetabular fractures in the elderly with fixation and primary arthroplasty: aiming for early weightbearing.

    PubMed

    Rickman, Mark; Young, James; Trompeter, Alex; Pearce, Rachel; Hamilton, Mark

    2014-11-01

    Osteoporotic acetabular fractures in the elderly are becoming more common. Regardless of treatment, most patients are managed with a period of protected weightbearing, even if a THA has been performed. We have tried to treat these patients analogously to geriatric femoral neck fractures in a way that allows immediate full weightbearing. We determined return to mobility, length of hospital stay (LOS), radiographic outcomes, and complications in a series of elderly osteoporotic patients treated for acetabular fractures with early fracture fixation and simultaneous THA, allowing full weightbearing immediately postoperatively. Since 2009, one surgeon (MR) used a consistent approach for fracture fixation and THA with immediate weightbearing in all patients older than 65 years with acetabular fractures who were fit for surgery and whose injuries were deemed osteoporotic fractures (low-energy mechanisms) meeting particular radiographic criteria (significant marginal impaction or femoral head damage). Twenty-four patients met these criteria and were reviewed at a mean of 24 months (range, 8-38 months). Mean age was 77 years (range, 63-90 years), and eight patients were women. The surgical technique included plate stabilization of both acetabular columns plus simultaneous THA using a tantalum socket and a cemented femoral stem. Clinical and note reviews were conducted to ascertain return to mobility, LOS, and postoperative complications. Component migration and fracture healing were assessed on plain radiographs. All patients mobilized with full weightbearing by Day 7 postoperatively. Only one patient remained dependent on a frame to mobilize at discharge. At 6 weeks, two patients already required no walking aids. At 6 months, patients were using a single stick at home at most, and all patients had managed stairs. Mean LOS was 18 days (range, 10-36 days). Radiographically, no component migration was seen in any patient. Seventeen of 24 fractures (71%) healed

  18. Direct and indirect costs of surgically treated pelvic fractures.

    PubMed

    Aprato, Alessandro; Joeris, Alexander; Tosto, Ferdinando; Kalampoki, Vasiliki; Stucchi, Alessandro; Massè, Alessandro

    2016-03-01

    Pelvic fractures requiring surgical fixation are rare injuries but present a great societal impact in terms of disability, as well as economic resources. In the literature, there is no description of these costs. Main aim of this study is to describe the direct and indirect costs of these fractures. Secondary aims were to test if the type of fracture (pelvic ring injury or acetabular fracture) influences these costs (hospitalization, consultation, medication, physiotherapy sessions, job absenteeism). We performed a retrospective study on patients with surgically treated acetabular fractures or pelvic ring injuries. Medical records were reviewed in terms of demographic data, follow-up, diagnosis (according to Letournel and Tile classifications for acetabular and pelvic fractures, respectively) and type of surgical treatment. Patients were interviewed about hospitalization length, consultations after discharge, medications, physiotherapy sessions and absenteeism. The study comprised 203 patients, with a mean age of 49.1 ± 15.6 years, who had undergone surgery for an acetabular fracture or pelvic ring injury. The median treatment costs were 29.425 Euros per patient. Sixty percent of the total costs were attributed to health-related work absence. Median costs (in Euros) were 2.767 for hospitalization from trauma to definitive surgery, 4.530 for surgery, 3.018 for hospitalization in the surgical unit, 1.693 for hospitalization in the rehabilitation unit, 1.920 for physiotherapy after discharge and 402 for consultations after discharge. Total costs for treating pelvic ring injuries were higher than for acetabular fractures, mainly due to the significant higher costs of pelvic injuries regarding hospitalization from trauma to definitive surgery (p < 0.001) and hospitalization in the surgical unit (p = 0.008). Pelvic fractures are associated with both high direct costs and substantial productivity loss.

  19. The epidemiology and injury patterns of acetabular fractures: are the USA and China comparable?

    PubMed

    Mauffrey, Cyril; Hao, Jiandong; Cuellar, Derly O; Herbert, Benoit; Chen, Xiao; Liu, Bo; Zhang, Yingze; Smith, Wade

    2014-11-01

    Acetabular fractures are rare injuries in heterogeneous patient groups, making it difficult to develop adequately powered prospective single-center clinical trials in the USA or Europe. Chinese trauma centers treat a high volume of these injuries, and if the patient population and injury patterns are comparable to those in the USA, this might support development of multicenter studies in Level I trauma centers in the two countries. We determined whether the following parameters were similar between operative acetabular fractures treated at Chinese and US trauma centers: (1) epidemiology of injured patients, (2) mechanism of injuries and fracture types, and (3) hospital stay parameters, including symptomatic postoperative deep vein thrombosis (DVT) rate. We extracted data from trauma databases for patients admitted with acetabular fractures managed surgically from 2005 to 2012 for one Chinese center and from 2008 to 2012 for one US center. Sex, age, mechanism of injury, fracture classification, Injury Severity Score (ISS), time from injury to surgery, length of hospital stay, and symptomatic DVT rate were analyzed. We included 661 Chinese patients (539 men, 122 women) and 212 US patients (163 men, 49 women). Mean age at time of injury was different between China and the USA, at 40 years with a unimodal distribution and 44 years with a bimodal distribution (p<0.001), respectively. Incidence of surgically treated acetabular fractures has been increasing in China but decreasing in the USA. Mean ISSs were comparable. Although the distribution of mechanisms of injury was different (p=0.004), high-energy injuries (motor vehicle accidents, falls>10 feet) still accounted for most fractures in both centers. Fracture classifications (per Letournel) were comparable, with posterior wall fractures most common. Mean time from injury to surgery and mean hospital stay were longer in China than in the USA (9 versus 3 days [p<0.001] and 26 versus 11 days [p<0.001], respectively

  20. Computer assisted surgery in preoperative planning of acetabular fracture surgery: state of the art.

    PubMed

    Boudissa, Mehdi; Courvoisier, Aurélien; Chabanas, Matthieu; Tonetti, Jérôme

    2018-01-01

    The development of imaging modalities and computer technology provides a new approach in acetabular surgery. Areas covered: This review describes the role of computer-assisted surgery (CAS) in understanding of the fracture patterns, in the virtual preoperative planning of the surgery and in the use of custom-made plates in acetabular fractures with or without 3D printing technologies. A Pubmed internet research of the English literature of the last 20 years was carried out about studies concerning computer-assisted surgery in acetabular fractures. The several steps for CAS in acetabular fracture surgery are presented and commented by the main author regarding to his personal experience. Expert commentary: Computer-assisted surgery in acetabular fractures is still initial experiences with promising results. Patient-specific biomechanical models considering soft tissues should be developed to allow a more realistic planning.

  1. Biocompatibility of Bespoke 3D-Printed Titanium Alloy Plates for Treating Acetabular Fractures.

    PubMed

    Lin, Xuezhi; Xiao, Xingling; Wang, Yimeng; Gu, Cheng; Wang, Canbin; Chen, Jiahui; Liu, Han; Luo, Juan; Li, Tao; Wang, Di; Fan, Shicai

    2018-01-01

    Treatment of acetabular fractures is challenging, not only because of its complicated anatomy but also because of the lack of fitting plates. Personalized titanium alloy plates can be fabricated by selective laser melting (SLM) but the biocompatibility of these three-dimensional printing (3D-printed) plates remains unknown. Plates were manufactured by SLM and their cytocompatibility was assessed by observing the metabolism of L929 fibroblasts incubated with culture medium extracts using a CCK-8 assay and their morphology by light microscopy. Allergenicity was tested using a guinea pig maximization test. In addition, acute systemic toxicity of the 3D-printed plates was determined by injecting extracts from the implants into the tail veins of mice. Finally, the histocompatibility of the plates was investigated by implanting them into the dorsal muscles of rabbits. The in vitro results suggested that cytocompatibility of the 3D-printed plates was similar to that of conventional plates. The in vivo data also demonstrated histocompatibility that was comparable between the two manufacturing techniques. In conclusion, both in vivo and in vitro experiments suggested favorable biocompatibility of 3D-printed titanium alloy plates, indicating that it is a promising option for treatment of acetabular fractures.

  2. Bilateral non-traumatic acetabular and femoral neck fractures due to pregnancy-associated osteoporosis.

    PubMed

    Aynaci, Osman; Kerimoglu, Servet; Ozturk, Cagatay; Saracoglu, Metehan

    2008-03-01

    Pregnancy-associated osteoporosis is a rare disorder and its pathophysiology remains unknown. We report a case of pregnancy-associated osteoporosis in a 27-year-old primiparous patient who revealed bilateral hip pain during early postnatal period. The plain radiographs and computerized tomography showed bilateral femoral neck and acetabular fractures. The diagnosis of osteoporosis was established by bone mineral density. Diagnostic work-up excluded a secondary osteoporosis. The case was treated successfully by bilateral cementless total hip arthroplasty. Bone mineral density increased after 2 years of treatment with calcium-vitamin D, calcitriol and alendronate. Diagnosis of pregnancy-associated osteoporosis should be suspected when hip pain occurs during pregnancy or in the post-partum period as it can lead to acetabular and femoral neck fractures.

  3. Biocompatibility of Bespoke 3D-Printed Titanium Alloy Plates for Treating Acetabular Fractures

    PubMed Central

    Xiao, Xingling; Wang, Yimeng; Gu, Cheng; Wang, Canbin; Chen, Jiahui; Liu, Han; Luo, Juan; Li, Tao

    2018-01-01

    Treatment of acetabular fractures is challenging, not only because of its complicated anatomy but also because of the lack of fitting plates. Personalized titanium alloy plates can be fabricated by selective laser melting (SLM) but the biocompatibility of these three-dimensional printing (3D-printed) plates remains unknown. Plates were manufactured by SLM and their cytocompatibility was assessed by observing the metabolism of L929 fibroblasts incubated with culture medium extracts using a CCK-8 assay and their morphology by light microscopy. Allergenicity was tested using a guinea pig maximization test. In addition, acute systemic toxicity of the 3D-printed plates was determined by injecting extracts from the implants into the tail veins of mice. Finally, the histocompatibility of the plates was investigated by implanting them into the dorsal muscles of rabbits. The in vitro results suggested that cytocompatibility of the 3D-printed plates was similar to that of conventional plates. The in vivo data also demonstrated histocompatibility that was comparable between the two manufacturing techniques. In conclusion, both in vivo and in vitro experiments suggested favorable biocompatibility of 3D-printed titanium alloy plates, indicating that it is a promising option for treatment of acetabular fractures. PMID:29682523

  4. [One-stage operation for pelvis and acetabular fractures combined with Morel-Lavallée injury by internal fixation associated with vacuum sealing drainage].

    PubMed

    Wei, Dan; Wang, Yue; Yuan, Jiabin; Tang, Xiaoming; Zhang, Bin; Lu, Bing; Tan, Bo

    2014-01-01

    To investigate the methods and effectiveness of one-stage operation for pelvis and acetabular fractures combined with Morel-Lavallée injury by internal fixation associated with vacuum sealing drainage (VSD). Between June 2008 and October 2012, 15 cases of pelvis and acetabular fractures combined with Morel-Lavallée injury were treated. There were 5 males and 10 females, aged from 18 to 67 years (mean, 36.8 years). Fractures were caused by traffic accident in 11 cases and crashing injury of heavy object in 4 cases. The time from injury to hospitalization was 3 hours to 9 days (mean, 5.4 days). Morel-Lavallée injury located in the above posterior superior iliac spine in 4 cases, greater trochanter in 7 cases, and anterior proximal thigh in 4 cases. In 10 cases complicated by pelvic fracture, there were 1 case of anteroposterior compression type, 3 cases of lateral compression type, 5 cases of vertical shear type, and 1 case of compound injury type; in 5 cases complicated by acetabular fracture, there were 1 case of transverse fracture, 1 case of posterior wall and posterior column fracture, 1 case of transverse acetabulum plus posterior wall fracture, and 2 cases of both columns fracture. Open reduction and internal fixation were used to treat pelvic and acetabular fractures, and VSD to treat Morel-Lavallée injury. When the drainage volume was less than 20 mL/d, interrupted wound suture or free skin grafting was performed. The hospitalization time was 16-31 days (mean, 20.8 days). Thirteen cases were followed up 4-16 months (mean, 7.8 months). The healing time of Morel-Lavallée injury was 16-36 days after operation (mean, 21.3 days). All the wounds had primary healing, and no infection occurred. The X-ray films showed that all fractures healed, with a mean healing time of 13.6 weeks (range, 11-18 weeks). At 6.5 months after operation, according to Majeed function scoring system in 8 cases of pelvic fracture, the results were excellent in 5 cases, good in 2 cases

  5. The development and nature of femoral head cam lesions following acetabular fractures.

    PubMed

    Berber, Onur; Foote, Julian; Sabharwal, Sanjeeve; Datta, Gorav; Bircher, Martin D

    2014-01-01

    The aim of acetabular fracture fixation is to restore joint congruity with restoration of the articular surface. Poor outcomes are seen where this has not been achieved. Letournel reported a collarette osteophyte seen postoperatively in a proportion of patients, which he suggested was an early precursor to the development of osteoarthritis. This is a retrospective study of patients treated at a tertiary referral unit who developed this lesion. The triangular index was measured in 48 of these patients and then correlated with their clinical findings, Oxford Hip Score and the presence of osteoarthritis. Length of follow-up, fracture classification, and joint congruency were also recorded. Results showed a statistically significant relationship between cam lesion size and the development of osteoarthritis (P = 0.008), cam lesion size and length of follow-up (P = 0.01), and between groin pain and postoperative joint congruency (LR = 0.035). These findings suggest that the appearance of a cam lesion is a poor long-term prognostic marker for the development of osteoarthritis in patients with an acetabular fracture.

  6. [Contact characteristics research of acetabular weight-bearing area with different internal fixation methods after compression fracture of acetabular dome].

    PubMed

    Xu, Bowen; Zhang, Qingsong; An, Siqi; Pei, Baorui; Wu, Xiaobo

    2017-08-01

    To establish the model of compression fracture of acetabular dome, and to measure the contact characteristics of acetabular weight-bearing area of acetabulum after 3 kinds of internal fixation. Sixteen fresh adult half pelvis specimens were randomly divided into 4 groups, 4 specimens each group. Group D was the complete acetabulum (control group), and the remaining 3 groups were prepared acetabular dome compression fracture model. The fractures were fixed with reconstruction plate in group A, antegrade raft screws in group B, and retrograde raft screws in group C. The pressure sensitive films were attached to the femoral head, and the axial compression test was carried out on the inverted single leg standing position. The weight-bearing area, average stress, and peak stress were measured in each group. Under the loading of 500 N, the acetabular weight-bearing area was significantly higher in group D than in other 3 groups ( P <0.05), and the average stress and peak stress were significantly lower than in other 3 groups ( P <0.05). The acetabular weight-bearing area were significantly higher in group B and group C than in group A, and the average stress and peak stress were significantly lower than in group A ( P <0.05). There was no significant difference in the above indexes between group B and group C ( P >0.05). For the compression fracture of the acetabular dome, the contact characteristics of the weight-bearing area can not restore to the normal level, even if the anatomical reduction and rigid internal fixation were performed; compared with the reconstruction plate fixation, antegrade and retrograde raft screws fixations can increase the weight-bearing area, reduce the average stress and peak stress, and reduce the incidence of traumatic arthritis.

  7. Stabilization of an acetabular fracture with cables for acute total hip arthroplasty.

    PubMed

    Mears, D C; Shirahama, M

    1998-01-01

    A critical stage of total hip arthroplasty for an acute acetabular fracture where extensive comminution, impaction, and osteopenia thwart the application of conventional open or closed methods, especially in the elderly, is stable fixation of the acetabulum. The use of 2-mm braided cables permits effective immobilization of the fracture for use in conjunction with a hybrid arthroplasty. The method is consistent with the use of a conventional arthroplastic incision and is suitable for other applications including the fixation of periprosthetic fractures, bulk allografts, and conventional acetabular fractures.

  8. Survivorship of the native hip joint after percutaneous repair of acetabular fractures in the elderly.

    PubMed

    Gary, Joshua L; Lefaivre, Kelly A; Gerold, Frank; Hay, Michael T; Reinert, Charles M; Starr, Adam J

    2011-10-01

    Our purpose was to examine survivorship of the native hip joint in patients ages 60 and over who underwent percutaneous reduction and fixation of acetabular fractures. A retrospective review at a University Level I Trauma Center was performed. Our institutional trauma database was reviewed. Patients aged 60 or older treated with percutaneous reduction and fixation of acetabular fractures between 1994 and 2007 were selected. 79 consecutive patients with 80 fractures were identified. Rate of conversion to total hip arthroplasty were used to construct a Kaplan-Meier curve showing survivorship of the native hip joint after treatment. 75 fractures had adequate clinical follow-up with a mean of 3.9 years (range 0.5-11.9 years). Average blood loss was 69 cc and there were no postoperative infections. 19/75 (25%) were converted to total hip arthroplasty at a mean time of 1.4 years after the index procedure. Survivorship analysis demonstrated a cumulative survival of 65% at 11.9 years of follow-up. There were no conversions to arthroplasty beyond 4.7 years postoperatively. There were no statistically significant associations between conversion to arthroplasty and age, sex, closed vs. limited open reduction, and simple vs. complex fracture pattern. Percutaneous fixation is a viable treatment option for patients age 60 or greater with acetabular fractures. Rates of conversion to total hip arthroplasty are comparable to open treatment methods and if conversion is required, soft tissues are preserved for future surgery. Copyright © 2010 Elsevier Ltd. All rights reserved.

  9. How often does open reduction and internal fixation of geriatric acetabular fractures lead to hip arthroplasty?

    PubMed

    O'Toole, Robert V; Hui, Emily; Chandra, Amit; Nascone, Jason W

    2014-03-01

    We hypothesized that open reduction and internal fixation (ORIF) of displaced acetabular fractures in geriatric patients result in a low rate of conversion to hip arthroplasty and satisfactory hip-specific validated outcome scores at medium-term follow-up. Retrospective review. Level I trauma center. One hundred forty-seven consecutive patients who were 60 years or older who had acetabular fractures were treated at our center from 2001 through 2006. During this time period, fractures meeting operative criteria were treated with ORIF unless medical conditions warranted nonoperative treatment. Twenty-nine patients were lost to follow-up, 46 were deceased, and 11 declined to participate, leaving 61 potential patients for inclusion, 46 of whom were treated with ORIF (average follow-up, 4.4 years; range, 1.1-8.0 years). Standardized telephone interviews included hip-specific questions and validated outcome measures. Rates of conversion to hip arthroplasty and hip-specific validated outcome scores. Among 46 patients treated with ORIF (15 others were treated nonoperatively or with percutaneous screw fixation), 28% underwent hip arthroplasty an average 2.5 years after injury (range, 0.4-5.5 years) and had an average Western Ontario and McMaster Universities Index of Osteoarthritis score of 17 (range, 0-56; n = 38). This score is similar to or better than the typical scores after elective arthroplasty for arthritis and much better than the scores for patients with established arthritis (P < 0.05). The average SF-8 Health Survey physical component score was 46.1 (range, 31-62), similar to US population norms for the geriatric age group (P > 0.20). Few data exist regarding the treatment outcomes for geriatric acetabular fractures. It is difficult for clinicians to decide among ORIF, percutaneous fixation, acute arthroplasty, and nonoperative treatment. Our protocol of mostly ORIF showed a high 1-year mortality rate of 25% and a rate of conversion to arthroplasty after ORIF of

  10. Treatment of acetabular fractures in older patients-introduction of a new implant for primary total hip arthroplasty.

    PubMed

    Resch, H; Krappinger, D; Moroder, P; Auffarth, A; Blauth, M; Becker, J

    2017-04-01

    Fractures of the acetabulum in younger patients are commonly treated by open reduction and internal fixation. For elderly patients, stable primary total hip arthroplasty with the advantage of immediate postoperative mobilization might be the adequate treatment. For this purpose, a sufficiently stable fixation of the acetabular component is required. Between August 2009 and 2014, 30 cases were reported in which all patients underwent total hip arthroplasty additionally to a customized implant designed as an antiprotrusion cage. Inclusion criteria were an acetabular fracture with or without a previous hemiarthroplasty, age above 65 years, and pre-injury mobility dependent on a walking frame at the most. The median age was 79.9 years (65-92), and of 30 fractures, 25 were primary acetabular fractures (83%), four periprosthetic acetabular fractures (14%), and one non-union after a failed ORIF (3%). The average time from injury to surgery was 9.4 days (3-23) and 295 days for the non-union case. Mean time of surgery was 154.4 min (range 100 to 303). In 21 cases (70%), mobilization with full weight bearing was possible within the first 10 days. Six patients died before the follow-up examination 3 and 6 months after surgery, while 24 patients underwent radiologic examination showing consolidated fractures in bi-plane radiographs. In 9 patients, additional CT scan was performed which confirmed the radiographical results. 13 had regained their pre-injury level of mobility including the non-union case. Only one patient did not regain independent mobility. Four complications were recognized with necessary surgical revision (one prosthetic head dislocation, one pelvic cement leakage, one femoral shaft fracture, and one infected hematoma). The presented cage provides the possibility of early mobilization with full weight bearing which represents a valuable addition to the treatment spectrum in this challenging patient group.

  11. Reconstruction of the pelvic brim and its role in the reduction accuracy of displaced T-shaped acetabular fracture.

    PubMed

    Harnroongroj, T; Asavamongkolkul, A; Chareancholvanich, K

    2000-05-01

    Open reduction of the displaced T-shaped acetabular fracture has a problem of accuracy of the fracture reduction. This study was carried out to demonstrate that the reconstruction of the pelvic brim by approaching the pubo-acetabular fragment plays a role in the accuracy of the reduction of displaced T-shaped acetabular fractures. From 1975 to 1990, a retrospective study was carried out of 22 patients who sustained a displaced T-shaped acetabular fracture. The patients were operated on by open reduction and internal fixation of the ischio-acetabular fragment to the posterior column without restoration of the pelvic brim. Radiographs of the pelvis were reviewed. The result showed that there was displacement of the pubo-acetabular fragment including the medial wall in all cases. As the result of this study, a prospective study between 1990 and 1997 was carried out of 15 patients who sustained displaced T-shaped acetabular fractures including 3 cases with medial displacement of the femoral head. The pubo-acetabular fragment was anatomically reduced and fixed to the anterior column of the acetabulumn as the first approach to restore a disrupted pelvic brim. There, patterns of the acetabular fracture were subsequently re-evaluated especially the ischio-acetabular fragment including the position of the femoral head by using an intraoperative portable X-ray technique. The stability of the hip joint was assessed by hip flexion. The intraoperative radiograph appearances of the ischio-acetabular fragment were visually confirmed by a second surgical exposure. The results showed that the intraoperative radiographs gave spontaneous reduction of the ischio-acetabular fragment in all patients except one. There was a reduction of the displaced femoral head into the hip socket in the three patients. The hip joints were stable in all patients. The second surgical exposure showed that there was good spontaneous reduction of the ischio-acetabular fragment to the posterior column by

  12. Radiographic Measurement of Displacement in Acetabular Fractures: A Systematic Review of the Literature.

    PubMed

    Dodd, Andrew; Osterhoff, Georg; Guy, Pierre; Lefaivre, Kelly A

    2016-06-01

    To report methods of measurement of radiographic displacement and radiographic outcomes in acetabular fractures described in the literature. A systematic review of the English literature was performed using EMBASE and Medline in August 2014. Inclusion criteria were studies of operatively treated acetabular fractures in adults with acute (<6 weeks) open reduction and internal fixation that reported radiographic outcomes. Exclusion criteria included case series with <10 patients, fractures managed >6 weeks from injury, acute total hip arthroplasty, periprosthetic fractures, time frame of radiographic outcomes not stated, missing radiographic outcome data, and non-English language articles. Basic information collected included journal, author, year published, number of fractures, and fracture types. Specific data collected included radiographic outcome data, method of measuring radiographic displacement, and methods of interpreting or categorizing radiographic outcomes. The number of reproducible radiographic measurement techniques (2/64) and previously described radiographic interpretation methods (4) were recorded. One radiographic reduction grading criterion (Matta) was used nearly universally in articles that used previously described criteria. Overall, 70% of articles using this criteria documented anatomic reductions. The current standard of measuring radiographic displacement in publications dealing with acetabulum fractures almost universally lacks basic description, making further scientific rigor, such as testing reproducibility, impossible. Further work is necessary to standardize radiographic measurement techniques, test their reproducibility, and qualify their validity or determine which measurements are important to clinical outcomes. Diagnostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  13. Sarcopenia Is Predictive of 1-Year Mortality After Acetabular Fractures in Elderly Patients.

    PubMed

    Mitchell, Phillip M; Collinge, Cory A; OʼNeill, David E; Bible, Jesse E; Mir, Hassan R

    2018-06-01

    To determine whether sarcopenia is an independent predictor of mortality in geriatric acetabular fractures. Retrospective cohort. American College of Surgeons Level I trauma center. One hundred and forty-six patients over the age 60 with acetabular fractures treated at our institution over a 12-year period. The primary outcome was 1-year mortality, collected using the Social Security Death Index. We used the psoas:lumbar vertebral index (PLVI), calculated using the cross-sectional area of the L4 vertebral body and the left and right psoas muscles, to assess for sarcopenia. Using a multivariate logistic regression model, we found that low PLVI was associated with increased 1-year mortality (P = 0.046) when controlling for age, gender, Charlson Comorbidity Index, Injury Severity Score (ISS), smoking status, and associated pelvic ring injury. Increasing age and ISS also showed a relationship with 1-year mortality in this cohort (P < 0.001, P < 0.001, respectively). We defined sarcopenia as those patients in the lowest quartile of PLVI. The mortality rate of this cohort was 32.4%, compared with 11.0% in patients without sarcopenia (odds ratio 4.04; 95% confidence interval 1.62-10.1). Age >75 years, ISS >14, and sarcopenia had 1-year mortality rates of 37.1%, 30.9%, and 32.4%, respectively. In patients with all 3 factors, the mortality rate was 90%. Sarcopenia is an independent risk factor for 1-year mortality in elderly patients with acetabular fractures. This study highlights the importance of objective measures to assess frailty in elderly patients who have sustained fractures about the hip and pelvis. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  14. 3D surgical printing and pre contoured plates for acetabular fractures.

    PubMed

    Chana-Rodríguez, Francisco; Mañanes, Rubén Pérez; Rojo-Manaute, José; Gil, Pablo; Martínez-Gómiz, José María; Vaquero-Martín, Javier

    2016-11-01

    We describe the methodical and possibilities of 3D surgical printing in preoperative planning of acetabular fractures showing a case of a 45-year-old with an associated transverse fracture of the left acetabulum with posterior wall fracture, with multiple fragments, and posterior ipsilateral hip dislocation, defending the do it your-self mode. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Direct hip joint distraction during acetabular fracture surgery using the AO universal manipulator.

    PubMed

    Calafi, L Afshin; Routt, M L Chip

    2010-02-01

    Certain acetabular fractures may necessitate distraction of the hip joint for removal of intra-articular debris and assessment of reduction. Distraction can be accomplished by manual traction, using a traction table or an AO universal manipulator (UM). The UM is a relatively simple and an inexpensive device that can provide focal distraction in a controlled manner without the risks associated with the use of a traction table. We describe a technique using the UM for hip joint distraction during acetabular fracture surgery through a Kocher-Langenbeck surgical exposure.

  16. Secure Screw Placement in Management of Acetabular Fractures Using the Suprapectineal Quadrilateral Buttress Plate.

    PubMed

    Egli, R J; Keel, M J B; Cullmann, J L; Bastian, J D

    2017-01-01

    Acetabular fractures involving predominantly the anterior column associated with a disruption of the quadrilateral surface can be treated with instrumentation implementing the stabilization of the quadrilateral surface. The recently introduced suprapectineal quadrilateral buttress plate is specifically designed to prevent secondary medial subluxation of the femoral head, especially in elderly patients with reduced ability for partial weight bearing. Whereas there are guidelines available for safe screw fixation for the anterior and posterior columns, there might be a concern for intra-articular placement of screws placed through the infrapectineal part of the quadrilateral buttress plate. Within this report we analyzed retrospectively screw placement in 30 plates in postoperative CT scans using algorithms for metal artifact reduction. None of the screws of the buttress plate penetrated the hip joint. We describe the placement, length, and spatial orientation of the screws used for fracture fixation and suggest that the use of intraoperative image intensifiers with a combined inlet-obturator view of 30-45° best projects the screws and the hip joint. Preoperative knowledge of approximate screw placement and information for accurate intraoperative imaging may contribute to safe acetabular fracture fixation and may reduce operating time and limit radiation exposure to the patient and the personnel. This trial is registered with KEK-BE: 266/2014.

  17. The effect of variable size posterior wall acetabular fractures on contact characteristics of the hip joint.

    PubMed

    Olson, S A; Bay, B K; Pollak, A N; Sharkey, N A; Lee, T

    1996-01-01

    The indications for open reduction and internal fixation of posterior wall acetabular fractures associated with a clinically stable hip joint are unclear. In previous work a large posterior wall defect (27% articular surface area) resulted in significant alteration of load transmission across the hip; specifically, there was a transition from evenly distributed loading along the acetabular articular surface to loading concentrated mainly in the superior portion of the articular surface during simulated single leg stance. However, the majority of posterior wall fractures involve a smaller amount of the articular surface. Posterior wall acetabular fractures not associated with instability of the hip are commonly treated nonoperatively. This practice does not account for the size of the posterior wall fracture. To study the biomechanical consequences of variably sized articular defects, a laboratory experiment was conducted evaluating three progressively larger posterior wall defects of the acetabulum during simulated single leg stance using superlow Fuji prescale film (Itochu International, New York): (a) 1/3 articular surface width through a 50 degrees arc along the posterior wall of the acetabulum, (b) 2/3, and (c) 3/3 articular width defects through the same 50 degrees arc along the posterior wall of the acetabulum. In the intact acetabulum, 48% of the total articular contact was located in the superior acetabulum. Twenty-eight percent of articular contact was in the anterior wall region of the acetabulum and 24% in the posterior wall region. After the 1/3 width posterior wall defect, 64% of the articular contact was located in the superior acetabulum (p = 0.0011). The 2/3 width posterior wall defect resulted in 71% of articular contact area being located in the superior acetabulum (p = 0.0006). After the 3/3 width posterior wall defect, 77% of articular contact was located in the superior acetabulum, significantly greater than the intact condition (p < 0

  18. [Correlation analysis between residual displacement and hip function after reconstruction of acetabular fractures].

    PubMed

    Ma, Kunlong; Fang, Yue; Luan, Fujun; Tu, Chongqi; Yang, Tianfu

    2012-03-01

    To investigate the relationships between residual displacement of weight-bearing and non weight-bearing zones (gap displacement and step displacement) and hip function by analyzing the CT images after reconstruction of acetabular fractures. The CT measures and clinical outcome were retrospectively analyzed from 48 patients with displaced acetabular fracture between June 2004 and June 2009. All patients were treated by open reduction and internal fixation, and were followed up 24 to 72 months (mean, 36 months); all fractures healed after operation. The residual displacement involved the weight-bearing zone in 30 cases (weight-bearing group), and involved the non weight-bearing zone in 18 cases (non weight-bearing group). The clinical outcomes were evaluated by Merle d'Aubigné-Postel criteria, and the reduction of articular surface by CT images, including the maximums of two indexes (gap displacement and step displacement). All the data were analyzed in accordance with the Spearman rank correlation coefficient analysis. There was strong negative correlation between the hip function and the residual displacement values in weight-bearing group (r(s) = -0.722, P = 0.001). But there was no correlation between the hip function and the residual displacement values in non weight-bearing group (r(s) = 0.481, P = 0.059). The results of clinical follow-up were similar to the correlation analysis results. In weight-bearing group, the hip function had strong negative correlation with step displacement (r(s) = 0.825, P = 0.002), but it had no correlation with gap displacement (r(s) = 0.577, P = 0.134). In patients with acetabular fracture, the hip function has correlation not only with the extent of the residual displacement but also with the location of the residual displacement, so the residual displacement of weight-bearing zone is a key factor to affect the hip function. In patients with residual displacement in weight-bearing zone, the bigger the step displacement is, the

  19. Application of an innovative computerized virtual planning system in acetabular fracture surgery: A feasibility study.

    PubMed

    Wang, Huixiang; Wang, Fang; Newman, Simon; Lin, Yanping; Chen, Xiaojun; Xu, Lu; Wang, Qiugen

    2016-08-01

    Acetabular fracture surgery is amongst the most challenging tasks in the field of trauma surgery and careful preoperative planning is crucial for success. The aim of this paper is to describe the preliminary outcome of the utilization of an innovative computerized virtual planning system for acetabular fractures. 3D models of acetabular fractures and surrounding soft tissues from six patients were constructed from preoperative CT scans. A novel highly-automatic segmentation technique was performed on the 3D model to separate each fracture fragment, then 3D virtual reduction was performed. Additionally, the models were used to assess potential surgical approaches with reference to both the fracture and the surrounding soft tissues. The time required for virtual planning was recorded. After surgery, the virtual plan was compared to the real surgery with respect to surgical approach and reduction sequence. A Likert scale questionnaire was completed by the surgeons to evaluate their satisfaction with the system. Virtual planning was successfully completed in all cases. The planned surgical approach was followed in all cases with the planned reduction sequence followed completely in five cases and partially in one. The mean time required for virtual planning was 38.7min (range 21-57, SD=15.5). The mean time required for planning of B-type fractures was 25.0min (range 21-30, SD=4.6), of C-type fracture 52.3min (range 49-57, SD=4.2). The results of the questionnaire demonstrated a high level of satisfaction with the planning system. This study demonstrates that the virtual planning system is feasible in clinical settings with high satisfaction and acceptability from the surgeons. It provides a viable option for the planning of acetabular fracture surgery. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Does semi-automatic bone-fragment segmentation improve the reproducibility of the Letournel acetabular fracture classification?

    PubMed

    Boudissa, M; Orfeuvre, B; Chabanas, M; Tonetti, J

    2017-09-01

    The Letournel classification of acetabular fracture shows poor reproducibility in inexperienced observers, despite the introduction of 3D imaging. We therefore developed a method of semi-automatic segmentation based on CT data. The present prospective study aimed to assess: (1) whether semi-automatic bone-fragment segmentation increased the rate of correct classification; (2) if so, in which fracture types; and (3) feasibility using the open-source itksnap 3.0 software package without incurring extra cost for users. Semi-automatic segmentation of acetabular fractures significantly increases the rate of correct classification by orthopedic surgery residents. Twelve orthopedic surgery residents classified 23 acetabular fractures. Six used conventional 3D reconstructions provided by the center's radiology department (conventional group) and 6 others used reconstructions obtained by semi-automatic segmentation using the open-source itksnap 3.0 software package (segmentation group). Bone fragments were identified by specific colors. Correct classification rates were compared between groups on Chi 2 test. Assessment was repeated 2 weeks later, to determine intra-observer reproducibility. Correct classification rates were significantly higher in the "segmentation" group: 114/138 (83%) versus 71/138 (52%); P<0.0001. The difference was greater for simple (36/36 (100%) versus 17/36 (47%); P<0.0001) than complex fractures (79/102 (77%) versus 54/102 (53%); P=0.0004). Mean segmentation time per fracture was 27±3min [range, 21-35min]. The segmentation group showed excellent intra-observer correlation coefficients, overall (ICC=0.88), and for simple (ICC=0.92) and complex fractures (ICC=0.84). Semi-automatic segmentation, identifying the various bone fragments, was effective in increasing the rate of correct acetabular fracture classification on the Letournel system by orthopedic surgery residents. It may be considered for routine use in education and training. III: prospective

  1. [Use of the Omega plate for stabilisation of acetabular fractures: first experience].

    PubMed

    Šrám, J; Taller, S; Lukáš, R; Endrych, L

    2013-01-01

    The aim of our study is to solve the problem of insufficient fixation of comminuted fractures of the quadrilateral plane and the iliopectineal line. These fixation problems occur while using the standard narrow 3.5 mm fixation plate applied from a modified Stoppa approach. A new plate developed by the authors--the Omega plate--fulfils the requirements. In the period 2010-2012, we performed 156 stabilisations of pelvic ring fractures and acetabular fractures. We used the modified Stoppa approach applying the standard fixation plate in 24 patients and the Omega plate in 15 patients. The patient group with the Omega plate included 10 male and five female patients with the average age of 61 years (range, 30-72). Only 11 patients were followed up, with an average period of 13.3 months, because one patient was lost to followup and three patients were shortly after surgery. The surgical technique of Omega plate application is described in detail. The clinical evaluation of post-operative results was based on the Harris Hip Score; the graphical results were rated using the Matta and Pohlemann criteria. The Stoppa approach alone was used in four patients, combination of two approaches (Stoppa and Kocher-Langenbeck approach) was used in six cases and three approaches were employed in five patients. No adverse intra- or post-operative events were recorded. Excellent or satisfactory graphical results were obtained in 12 patients and an unsatisfactory graphical outcome was recorded in three cases. In the follow-up period ranging from 8 to 22 months, 11 patients healed. Late complications included avascular femoral head necrosis in two and severe post-traumatic coxarthrosis in three patients. Due to these complications, all five patients underwent total hip arthroplasty without previous Omega plate removal at an average interval of 15 months from the primary pelvic surgery. They were not included in the follow-up evaluation. The remaining six patients had an average Harris Hip

  2. A combination of three-dimensional printing and computer-assisted virtual surgical procedure for preoperative planning of acetabular fracture reduction.

    PubMed

    Zeng, Canjun; Xing, Weirong; Wu, Zhanglin; Huang, Huajun; Huang, Wenhua

    2016-10-01

    Treatment of acetabular fractures remains one of the most challenging tasks that orthopaedic surgeons face. An accurate assessment of the injuries and preoperative planning are essential for an excellent reduction. The purpose of this study was to evaluate the feasibility, accuracy and effectiveness of performing 3D printing technology and computer-assisted virtual surgical procedures for preoperative planning in acetabular fractures. We hypothesised that more accurate preoperative planning using 3D printing models will reduce the operation time and significantly improve the outcome of acetabular fracture repair. Ten patients with acetabular fractures were recruited prospectively and examined by CT scanning. A 3-D model of each acetabular fracture was reconstructed with MIMICS14.0 software from the DICOM file of the CT data. Bone fragments were moved and rotated to simulate fracture reduction and restore the pelvic integrity with virtual fixation. The computer-assisted 3D image of the reduced acetabula was printed for surgery simulation and plate pre-bending. The postoperative CT scan was performed to compare the consistency of the preoperative planning with the surgical implants by 3D-superimposition in MIMICS14.0, and evaluated by Matta's method. Computer-based pre-operations were precisely mimicked and consistent with the actual operations in all cases. The pre-bent fixation plates had an anatomical shape specifically fit to the individual pelvis without further bending or adjustment at the time of surgery and fracture reductions were significantly improved. Seven out of 10 patients had a displacement of fracture reduction of less than 1mm; 3 cases had a displacement of fracture reduction between 1 and 2mm. The 3D printing technology combined with virtual surgery for acetabular fractures is feasible, accurate, and effective leading to improved patient-specific preoperative planning and outcome of real surgery. The results provide useful technical tips in

  3. Management of acetabular fractures with modified posterior approach to spare external hip rotators.

    PubMed

    Sarlak, Ahmet Y; Selek, Ozgur; Inanir, Murat; Musaoglu, Resul; Baran, Tuncay

    2014-04-01

    In the present study the quality of reduction and incidence of complications in hip external rotator sparing modified posterior approach was assessed in both simple and complex acetabular fractures. This retrospective study includes 37 patients (38 hips) with a mean age of 42.1 years (range 21-60), that had been treated for displaced acetabular fractures from June 2007 through May 2011. They were reviewed at a mean of 3 years (20-67 months). The fractures were classified according to the Letournel-Judet classification. Anatomic reduction and stable fixation of the fracture with less than 2mm residual displacement was achieved in 28 of 38 hips. At the final follow up the patients were evaluated clinically according to Merle d'Aubigne and Postel scoring system which had been modified by Matta and radiologically based on the criteria described by Matta. The clinical results were excellent in 20, good in 8, fair in 8, and poor 2 hips. Complications included two superficial local wound infection and 10 heterotopic ossification with 7 of the cases having grade I heterotopic ossification. Avascular necrosis of the femoral head was not seen in any of the 38 hips. One patient with preoperative sciatic nerve palsy had complete recovery of neurologic function. There were no cases of deep vein thrombosis or pulmonary embolism. The functional outcome was satisfactory in most of the cases and comparable with other larger series. Using the limited part of Henry's sciatic nerve exposure skin incision - working in the plane between gluteus maximus and the tensor fascia lata as in the classical Gibson approach and two portal external rotator hip sparing approach resulted in good fracture reduction without approach related complications. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Acetabular fractures in the elderly treated with a primary Burch-Schneider reinforcement ring, autologous bone graft, and a total hip arthroplasty: a prospective study with a 4-year follow-up.

    PubMed

    Enocson, Anders; Blomfeldt, Richard

    2014-06-01

    To investigate the clinical and radiologic outcomes in elderly patients suffering from an acetabular fracture operated with an acute primary acetabular reinforcement ring, autologous bone graft, and a total hip arthroplasty (THA). Prospective cohort study. Tertiary care university hospital. Fifteen elderly patients (7 women) with a mean age of 76 years and a displaced acetabular fracture after a low-energy trauma were included. The fractures involved the anterior column, but no patients with associated both column fractures were included. All the patients were able to walk independently before the fracture occurred. Primary operation with a Burch-Schneider reinforcement ring, autologous bone graft, and a THA. The patients were reviewed at 4, 12, 24, and 48 months after the fracture occurred. The outcome assessments included complications, reoperations, activity of daily living function, functional scores (Harris hip score and short musculoskeletal function assessment), health-related quality of life [EuroQol (EQ-5D) index score], and radiologic evaluation. There were no prosthetic dislocations, periprosthetic fractures, deep infections, or other adverse events. There were no radiologic signs of loosening of the reinforcement ring or the prosthesis components at any of the follow up sessions, and the autologous bone graft was well incorporated in all the patients at the final follow-up. At 48 months, the mean Harris hip score was 88, the mean short musculoskeletal function assessment dysfunction score was 30, the bother score was 25, and the mean EQ-5D index score was 0.65. All the patients were able to walk independently at the final follow-up. Treatment of displaced anterior column, anterior column posterior hemitransverse and transverse acetabular fractures in elderly patients using a primary reinforcement ring, autologous bone graft, and a THA seems to be a safe option with good functional and radiologic outcomes. Therapeutic Level IV. See Instructions for

  5. Perioperative and acute care outcomes in morbidly obese patients with acetabular fractures at a Level 1 trauma center

    PubMed Central

    Vincent, Heather K.; Haupt, Edward; Tang, Sonya; Egwuatu, Adaeze; Vlasak, Richard; Horodyski, MaryBeth; Carden, Donna; Sadisivan, Kalia K.

    2014-01-01

    Background Controversy exists regarding obesity-related injury severity and clinical outcomes after orthopedic trauma. Purpose The purposes of this study were to expand our understanding of the effect of morbid obesity on perioperative and acute care outcomes after acetabular fracture. Methods This was a retrospective review of patients with acetabular fracture after trauma. Non-morbidly obese (BMI < 35 kg/m2) and morbidly obese (BMI ≥ 35 kg/m2; N = 81). Injury severity scores and Glasgow Coma Scale scores (GCS) were collected. Perioperative and acute care outcomes were positioning and operative time, extra fractures, estimated blood loss, complications, hospital charges, ventilator days, transfusions, length of stay (LOS) and discharge destination. Positioning and operative times were longer in morbidly obese patients (p < 0.05). No other differences existed between groups. Conclusions Orthopedic trauma surgeons and care teams can expect similar acute care outcomes in morbidly obese and non-morbidly obese patients with acetabular fracture. PMID:25104886

  6. Decreased Lumbar Lordosis and Deficient Acetabular Coverage Are Risk Factors for Subchondral Insufficiency Fracture.

    PubMed

    Jo, Woo Lam; Lee, Woo Suk; Chae, Dong Sik; Yang, Ick Hwan; Lee, Kyoung Min; Koo, Kyung Hoi

    2016-10-01

    Subchondral insufficiency fracture (SIF) of the femoral head occurs in the elderly and recipients of organ transplantation. Osteoporosis and deficient lateral coverage of the acetabulum are known risk factors for SIF. There has been no study about relation between spinopelvic alignment and anterior acetabular coverage with SIF. We therefore asked whether a decrease of lumbar lordosis and a deficiency in the anterior acetabular coverage are risk factors. We investigated 37 patients with SIF. There were 33 women and 4 men, and their mean age was 71.5 years (59-85 years). These 37 patients were matched with 37 controls for gender, age, height, weight, body mass index and bone mineral density. We compared the lumbar lordosis, pelvic incidence, pelvic tilt, sacral slope, acetabular index, acetabular roof angle, acetabular head index, anterior center-edge angle and lateral center-edge angle. Lumbar lordosis, pelvic tilt, sacral slope, lateral center edge angle, anterior center edge angle, acetabular index and acetabular head index were significantly different between SIF group and control group. Lumbar lordosis (OR = 1.11), lateral center edge angle (OR = 1.30) and anterior center edge angle (OR = 1.27) had significant associations in multivariate analysis. Decreased lumbar lordosis and deficient anterior coverage of the acetabulum are risk factors for SIF as well as decreased lateral coverage of the acetabulum.

  7. [Progress on treatment and research of quadrilateral plate fractures of acetabular].

    PubMed

    Peng, Ye; Zhang, Li-hai; Tang, Pei-fu

    2015-05-01

    Acetabular is an important human joint for weight bearing. Quadrilateral plate is a crucial structure of medial acetabulum with special morphology and important function. Quadrilateral plate fractures are common fracture in acetabulum. Quadrilateral plate fracture is hard to expose and reduction because it is in the medial of acetabulum. At the same time,the bone in the quadrilateral plate is not easy to fixed for thinning bones and adjacent to the articular cavity. The operator should know well about the anatomy and choose the suitable internal fixation. After quadrilateral plate fractures, the femur head maybe displace medially even break into pelvis. That make reduction and treatment always be a challenge. With different kinds of fractures,the efficacy of treatment is not the same. This paper intend to review the relation of anatomic features,approaches, internal fixations, key point of treatment and efficacy.

  8. [Application of 3D printing and computer-assisted surgical simulation in preoperative planning for acetabular fracture].

    PubMed

    Liu, Xin; Zeng, Can-Jun; Lu, Jian-Sen; Lin, Xu-Chen; Huang, Hua-Jun; Tan, Xin-Yu; Cai, Dao-Zhang

    2017-03-20

    To evaluate the feasibility and effectiveness of using 3D printing and computer-assisted surgical simulation in preoperative planning for acetabular fractures. A retrospective analysis was performed in 53 patients with pelvic fracture, who underwent surgical treatment between September, 2013 and December, 2015 with complete follow-up data. Among them, 19 patients were treated with CT three-dimensional reconstruction, computer-assisted virtual reset internal fixation, 3D model printing, and personalized surgery simulation before surgery (3D group), and 34 patients underwent routine preoperative examination (conventional group). The intraoperative blood loss, transfusion volume, times of intraoperative X-ray, operation time, Matta score and Merle D' Aubigne & Postel score were recorded in the 2 groups. Preoperative planning and postoperative outcomes in the two groups were compared. All the operations were completed successfully. In 3D group, significantly less intraoperative blood loss, transfusion volume, fewer times of X-ray, and shortened operation time were recorded compared with those in the conventional group (P<0.05). According to the Matta scores, excellent or good fracture reduction was achieved in 94.7% (18/19) of the patients in 3D group and in 82.4% (28/34) of the patients in conventional group; the rates of excellent and good hip function at the final follow-up were 89.5% (17/19) in the 3D group and 85.3% (29/34) in the conventional group (P>0.05). In the 3D group, the actual internal fixation well matched the preoperative design. 3D printing and computer-assisted surgical simulation for preoperative planning is feasible and accurate for management of acetabular fracture and can effectively improve the operation efficiency.

  9. [Aseptic, simultaneous and bilateral mobilisation due to an acetabular shell fracture in a 43 year-old patient].

    PubMed

    Ceretti, M; Fanelli, M; Pappalardo, S

    2014-01-01

    The acetabular shell mobilization is the main long-term complication in total hip replacement. Metal-back fracture has also to be considered among the possible causes of shell mobilization. A case is presented of bilateral acetabular shell mobilization due to the trabecular covering de-soldering from the metal-back in a 43 year-old patient, 13-14 years after the first surgery. Copyright © 2013 SECOT. Published by Elsevier Espana. All rights reserved.

  10. Intraoperative fluoroscopic evaluation of screw placement during pelvic and acetabular surgery.

    PubMed

    Yi, Chengla; Burns, Sean; Hak, David J

    2014-01-01

    The surgical treatment of pelvic and acetabular fractures can be technically challenging. Various techniques are available for the reconstruction of pelvic and acetabular fractures. Less invasive percutaneous fracture stabilization techniques, with closed reduction or limited open reduction, have been developed and are gaining popularity in the management of pelvic and acetabular fractures. These techniques require knowledge and interpretation of various fluoroscopic images to ensure appropriate and safe screw placement. Given the anatomic complexity of the intrapelvic structures and the 2-dimensional nature of standard fluoroscopy, multiple images oriented in different planes are needed to assess the accuracy of guide wire and screw placement. This article reviews the fluoroscopic imaging of common screw orientations during pelvic and acetabular surgery.

  11. [BIOMECHANICAL COMPARATIVE STUDY ON FOUR INTERNAL FIXATIONS FOR ACETABULAR FRACTURES IN QUADRILATERAL AREA].

    PubMed

    Wang, Lei; Wu, Xiaobo; Qi, Wei; Wang, Yongbin; He, Quanjie; Xu, Fengsong; Liu, Hongyang

    2015-10-01

    To compare the biomechanical difference of 4 kinds of internal fixations for acetabular fracture in quadrilateral area. The transverse fracture models were created in 16 hemipelves specimens from 8 adult males, and were randomly divided into 4 groups according to different internal fixation methods (n = 4): infrapectineal buttress reconstruction plate (group A), infrapectineal buttress locking reconstruction plate (group B), reconstruction plate combined with trans-plate quadrilateral screws (group C), and anterior reconstruction plate-lag screw (group D). Then the horizontal displacement, longitudinal displacement of fractures, and axial stiffness were measured and counted to compare the stability after continuous vertical loading. Under the same loading, the horizontal and longitudinal displacements of groups A, B, C, and D were decreased gradually; when the loading reached 1 800 N, the longitudinal displacement of group A was more than 3.00 mm, indicating the failure criterion, while the axial stiffness increased gradually. Under 200 N loading, there was no significant difference (P > 0.05) in horizontal displacement, longitudinal displacement, and axial stiffness among 4 groups. When the loading reached 600-1 800 N, significant differences were found in horizontal displacement, longitudinal displacement, and axial stiffness among 4 groups (P < 0.05) except the horizontal displacement between groups C and D (P > 0.05). For acetabular fracture in the quadrilateral area, anterior reconstruction plate-lag screw for internal fixation has highest stability, followed by reconstruction plate combined with trans-plate quadrilateral screws, and they are better than infrapectineal buttress reconstruction plate and infrapectineal buttress locking reconstruction plate.

  12. Usefulness of Arthroscopic Treatment of Painful Hip after Acetabular Fracture or Hip Dislocation.

    PubMed

    Hwang, Jung-Taek; Lee, Woo-Yong; Kang, Chan; Hwang, Deuk-Soo; Kim, Dong-Yeol; Zheng, Long

    2015-12-01

    Painful hip following hip dislocation or acetabular fracture can be an important signal for early degeneration and progression to osteoarthritis due to intraarticular pathology. However, there is limited literature discussing the use of arthroscopy for the treatment of painful hip. The purpose of this retrospective study was to analyze the effectiveness and benefit of arthroscopic treatment for patients with a painful hip after major trauma. From July 2003 to February 2013, we reviewed 13 patients who underwent arthroscopic treatment after acetabular fracture or hip dislocation and were followed up for a minimum of 2 postoperative years. The degree of osteoarthritis based on the Tonnis classification pre- and postoperatively at final follow-up was determined. Clinical outcomes were evaluated using visual analogue scale for pain (VAS) and modified Harris hip score (MHHS), and range of motion (ROM) of the hip pre- and postoperatively at final follow-up. There were nine male and four female patients with a mean age at surgery of 28 years (range, 20 to 50 years). The mean follow-up period of the patients was 59.8 months (range, 24 to 115 months), and the mean interval between initial trauma and arthroscopic treatment was 40.8 months (range, 1 to 144 months). At the final follow-up, VAS and MHHS improved significantly from 6.3 and 53.4 to 3.0 and 88.3, respectively (p = 0.002 and p < 0.001, respectively). However, there were no significant differences in hip flexion, abduction, adduction, external rotation, and internal rotation as minor improvements from 113.1°, 38.5°, 28.5°, 36.5°, and 22.7° to 118.5°, 39.0°, 29.2°, 38.9°, and 26.5° were observed, respectively (p = 0.070, p = 0.414, p = 0.317, p = 0.084, and p = 0.136, respectively). None of the patients exhibited progression of osteoarthritis of the hip at the final follow-up. Arthroscopic treatment after acetabular fracture or hip dislocation is effective and delays the progression of traumatic

  13. Should money follow the patient: Financial implication for being the National Centre for the Treatment and Management of Pelvic and Acetabular Fractures in Ireland.

    PubMed

    Kelly, M E; Leonard, M; Green, C; Beggs, R; Cheung, C; McElwain, J; Morris, S

    2013-12-01

    Pelvic and acetabular fractures are complex injuries requiring specialist treatment. Our institution is the National Centre for Treatment and Management of these injuries. To audit all referrals to our institution over a 6-month period and calculate the cost incurred by being the national referral centre. Retrospective review of database, and subsequent allocation of Casemix points to assess total cost of treatment for each patient referred to our institution. 103 patients referred with pelvic or acetabular fracture for operative management. The furthest referral distance was 181miles. Over-all, the length of stay was 15.4 days. The average inclusive cost for a referral to our unit for operative management was €16,302. Pelvic and acetabular fractures are complex injuries that require specialist referral unit management. However for these units to remain sustainable money needs to "follow the patient". Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  14. Internal Fixation of Complicated Acetabular Fractures Directed by Preoperative Surgery with 3D Printing Models.

    PubMed

    Liu, Zhao-Jie; Jia, Jian; Zhang, Yin-Guang; Tian, Wei; Jin, Xin; Hu, Yong-Cheng

    2017-05-01

    The purpose of this article is to evaluate the efficacy and feasibility of preoperative surgery with 3D printing-assisted internal fixation of complicated acetabular fractures. A retrospective case review was performed for the above surgical procedure. A 23-year-old man was confirmed by radiological examination to have fractures of multiple ribs, with hemopneumothorax and communicated fractures of the left acetabulum. According to the Letounel and Judet classification, T-shaped fracture involving posterior wall was diagnosed. A 3D printing pelvic model was established using CT digital imaging and communications in medicine (DICOM) data preoperatively, with which surgical procedures were simulated in preoperative surgery to confirm the sequence of the reduction and fixation as well as the position and length of the implants. Open reduction with internal fixation (ORIF) of the acetabular fracture using modified ilioinguinal and Kocher-Langenbeck approaches was performed 25 days after injury. Plates that had been pre-bent in the preoperative surgery were positioned and screws were tightened in the directions determined in the preoperative planning following satisfactory reduction. The duration of the operation was 170 min and blood loss was 900 mL. Postoperative X-rays showed that anatomical reduction of the acetabulum was achieved and the hip joint was congruous. The position and length of the implants were not different when compared with those in preoperative surgery on 3D printing models. We believe that preoperative surgery using 3D printing models is beneficial for confirming the reduction and fixation sequence, determining the reduction quality, shortening the operative time, minimizing preoperative difficulties, and predicting the prognosis for complicated fractures of acetabulam. © 2017 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  15. Modifier 22 for acetabular fractures in morbidly obese patients: does it affect reimbursement?

    PubMed

    Bergin, Patrick F; Kneip, Christopher; Pierce, Christine; Hendrix, Stephen T; Porter, Scott E; Graves, Matthew L; Russell, George V

    2014-11-01

    Modifier 22 in the American Medical Association's Current Procedural Terminology (CPT®) book is a billing code for professional fees used to reflect an increased amount of skill, time, and work required to complete a procedure. There is little disagreement that using this code in the setting of surgery for acetabulum fractures in the obese patient is appropriate; however, to our knowledge, the degree to which payers value this additional level of complexity has not been determined. We asked whether (1) the use of Modifier 22 increased reimbursements in morbidly obese patients and (2) there was any difference between private insurance and governmental payer sources in treatment of Modifier 22. Over a 4-year period, we requested immediate adjudication with payers when using Modifier 22 for morbidly obese patients with acetabular fractures. We provided payers with evidence of the increased time and effort required in treating this population. Reimbursements were calculated for morbidly obese and nonmorbidly obese patients. Of the 346 patients we reviewed, 57 had additional CPT® codes or modifiers appended to their charges and were excluded, leaving 289 patients. Thirty (10%) were morbidly obese and were billed with Modifier 22. Fifty-three (18%) were insured by our largest private insurer and 69 (24%) by governmental programs (Medicare/Medicaid). Eight privately insured patients (15%) and seven governmentally insured patients (10%) were morbidly obese and were billed with Modifier 22. For our primary question, we compared reimbursement rates between patients with and without Modifier 22 for obesity within the 289 patients. We then performed the same comparison for the 53 privately insured patients and the 69 governmentally insured patients. Overall, there was no change in mean reimbursement when using Modifier 22 in morbidly obese patients, compared to nonmorbidly obese patients (USD 2126 versus USD 2149, p < 0.94). There was also no difference in mean

  16. Biomechanical analysis using FEA and experiments of a standard plate method versus three cable methods for fixing acetabular fractures with simultaneous THA.

    PubMed

    Aziz, Mina S R; Dessouki, Omar; Samiezadeh, Saeid; Bougherara, Habiba; Schemitsch, Emil H; Zdero, Radovan

    2017-08-01

    Acetabular fractures potentially account for up to half of all pelvic fractures, while pelvic fractures potentially account for over one-tenth of all human bone fractures. This is the first biomechanical study to assess acetabular fracture fixation using plates versus cables in the presence of a total hip arthroplasty, as done for the elderly. In Phase 1, finite element (FE) models compared a standard plate method versus 3 cable methods for repairing an acetabular fracture (type: anterior column plus posterior hemi-transverse) subjected to a physiological-type compressive load of 2207N representing 3 x body weight for a 75kg person during walking. FE stress maps were compared to choose the most mechanically stable cable method, i.e. lowest peak bone stress. In Phase 2, mechanical tests were then done in artificial hemipelvises to compare the standard plate method versus the optimal cable method selected from Phase 1. FE analysis results showed peak bone stresses of 255MPa (Plate method), 205MPa (Mears cable method), 250MPa (Kang cable method), and 181MPa (Mouhsine cable method). Mechanical tests then showed that the Plate method versus the Mouhsine cable method selected from Phase 1 had higher stiffness (662versus 385N/mm, p=0.001), strength (3210versus 2060N, p=0.009), and failure energy (8.8versus 6.2J, p=0.002), whilst they were statistically equivalent for interfragmentary sliding (p≥0.179) and interfragmentary gapping (p≥0.08). The Plate method had superior mechanical properties, but the Mouhsine cable method may be a reasonable alternative if osteoporosis prevents good screw thread interdigitation during plating. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  17. The Anterior Intrapelvic Approach for Acetabular Fractures Using Approach-Specific Instruments and an Anatomical-Preshaped 3-Dimensional Suprapectineal Plate.

    PubMed

    Gras, Florian; Marintschev, Ivan; Grossterlinden, Lars; Rossmann, Markus; Graul, Isabel; Hofmann, Gunther O; Rueger, Johannes M; Lehmann, Wolfgang

    2017-07-01

    Anatomical acetabular plates the anterior intrapelvic approach (AIP) were recently introduced to fix acetabular fractures through the intrapelvic approach. Therefore, we asked the following: (1) Does the preshaped 3-dimensional suprapectineal plate interfere with or even impair the fracture reduction quality? (2) How often does the AIP approach need to be extended by the first (lateral) window of the ilioinguinal approach? Observational case series. Two Level 1 trauma centers. Patients with unstable acetabular fractures in 2014. Fracture fixation with anatomical-preshaped, 3-dimensional suprapectineal plates through the AIP approach ± the first window of the ilioinguinal approach. Fracture reduction results were measured in computed tomography scans and graded according to the Matta quality of reduction. Intraoperative parameters and perioperative complications were recorded. Radiological results (according to Matta) and functional outcome (modified Merle d'Aubigné score) were evaluated at 1-year follow-up. Thirty patients (9 women + 21 men; mean age ± SE: 64 ± 8 years) were included. The intrapelvic approach was solely used in 19 cases, and in 11 cases, an additional extension with the first window of the ilioinguinal approach (preferential for 2-column fractures) was performed. The mean operating time was 202 ± 59 minutes; the fluoroscopic time was 66 ± 48 seconds. Fracture gaps and steps in preoperative versus postoperative computed tomography scans were 12.4 ± 9.8 versus 2.0 ± 1.5 and 6.0 ± 5.5 versus 1.3 ± 1.7 mm, respectively. At 13.4 ± 2.9 months follow-up, the Matta grading was excellent in 50%, good in 25%, fair in 11%, and poor in 14% of cases. The modified Merle d'Aubigné score was excellent in 17%, good in 37%, fair in 33%, and poor in 13% of cases. The AIP approach using approach-specific instruments and an anatomical-preshaped, 3-dimensional suprapectineal plate became the standard procedure in our departments. Radiological and functional

  18. 3D printing utility for surgical treatment of acetabular fractures.

    PubMed

    Chana Rodríguez, F; Pérez Mañanes, R; Narbona Cárceles, F J; Gil Martínez, P

    2018-05-25

    Preoperative 3D modelling enables more effective diagnosis and simulates the surgical procedure. We report twenty cases of acetabular fractures with preoperative planning performed by pre-contouring synthesis plates on a 3D printed mould obtained from a computarized tomography (CT) scan. The mould impression was made with the DaVinci 1.0 printer model (XYZ Printing). After obtaining the printed hemipelvis, we proceeded to select the implant size (pelvic Matta system, Stryker ® ) that matched the characteristics of the fracture and the approach to be used. Printing the moulds took a mean of 385minutes (322-539), and 238grams of plastic were used to print the model (180-410). In all cases, anatomic reduction was obtained and intra-operative changes were not required in the initial contouring of the plates. The time needed to perform the full osteosynthesis, once the fracture had been reduced was 16.9minutes (10-24). In one case fixed with two plates, a postoperative CT scan showed partial contact of the implant with the surface of the quadrilateral plate. In the remaining cases, the contact was complete. In conclusion, our results suggest that the use of preoperative planning, by printing 3D mirror imaging models of the opposite hemipelvis and pre-contouring plates over the mould, might effectively achieve a predefined surgical objective and reduce the inherent risks in these difficult procedures. Copyright © 2018. Publicado por Elsevier España, S.L.U.

  19. Planning acetabular fracture reduction using patient-specific multibody simulation of the hip

    NASA Astrophysics Data System (ADS)

    Oliveri, Hadrien; Boudissa, Mehdi; Tonetti, Jerome; Chabanas, Matthieu

    2017-03-01

    Acetabular fractures are a challenge in orthopedic surgery. Computer-aided solutions were proposed to segment bone fragments, simulate the fracture reduction or design the osteosynthesis fixation plates. This paper addresses the simulation part, which is usually carried out by freely moving bone fragments with six degrees of freedom to reproduce the pre-fracture state. Instead we propose a different paradigm, closer to actual surgeon's requirements: to simulate the surgical procedure itself rather than the desired result. A simple, patient-specific, biomechanical multibody model is proposed, integrating the main ligaments and muscles of the hip joint while accounting for contacts between bone fragments. Main surgical tools and actions can be simulated, such as clamps, Schanz screws or traction of the femur. Simulations are computed interactively, which enables clinicians to evaluate different strategies for an optimal surgical planning. Six retrospective cases were studied, with simple and complex fracture patterns. After interactively building the models from preoperative CT, gestures from the surgical reports were reproduced. Results of the simulations could then be compared with postoperative CT data. A qualitative study shows the model behavior is excellent and the simulated reductions fit the observed data. A more quantitative analysis is currently being completed. Two cases are particularly significant, for which the surgical reduction actually failed. Simulations show it was indeed not possible to reduce these fractures with the chosen approach. Had our simulator being used, a better planning may have avoided a second surgery to these patients.

  20. [Osteosynthesis and cup revision in periprosthetic acetabulum fractures using a Kocher-Langenbeck approach].

    PubMed

    Schwabe, P; Märdian, S; Perka, C; Schaser, K-D

    2016-04-01

    Reconstruction/stable fixation of the acetabular columns to create an adequate periacetabular requirement for the implantation of a revision cup. Displaced/nondisplaced fractures with involvement of the posterior column. Resulting instability of the cup in an adequate bone stock situation. Periprosthetic acetabulum fractures with inadequate bone stock. Extended periacetabular defects with loss of anchorage options. Isolated periprosthetic fractures of the anterior column. Septic loosening. Dorsal approach. Dislocation of hip. Mechanical testing of inlaying acetabular cup. With unstable cup situation explantation of the cup, fracture fixation of acetabulum with dorsal double plate osteosynthesis along the posterior column. Cup revision. Hip joint reposition. Early mobilization; partial weight bearing for 12 weeks. Thrombosis prophylaxis. Clinical and radiological follow-ups. Periprosthetic acetabular fracture in 17 patients with 9 fractures after primary total hip replacement (THR), 8 after revision THR. Fractures: 12 due to trauma, 5 spontaneously; 7 anterior column fractures, 5 transverse fractures, 4 posterior column fractures, 1 two column fracture after hemiendoprosthesis. 5 type 1 fractures and 12 type 2 fractures. Operatively treated cases (10/17) received 3 reinforcement ring, 2 pedestal cup, 1 standard revision cup, cup-1 cage construct, 1 ventral plate osteosynthesis, 1 dorsal plate osteosynthesis, and 1 dorsal plate osteosynthesis plus cup revision (10-month Harris Hip Score 78 points). Radiological follow-up for 10 patients: consolidation of fractures without dislocation and a fixed acetabular cup. No revision surgeries during follow-up; 2 hip dislocations, 1 transient sciatic nerve palsy.

  1. Acetabular Morphology: Implications for Joint-preserving Surgery

    PubMed Central

    Ganz, Reinhold; Impellizzeri, Franco M.; Leunig, Michael

    2009-01-01

    Appropriate anatomic concepts for surgery to treat femoroacetabular impingement require a precise appreciation of the native acetabular anatomy. We therefore determined (1) the spatial acetabular rim profile, (2) the topography of the articular lunate surface, and (3) the 3-D relationships of the acetabular opening plane comparing 66 bony acetabula from 33 pelves in female and male pelves. The acetabular rim profile had a constant and regular wave-like outline without gender differences. Three prominences anterosuperiorly, anteroinferiorly and posteroinferiorly extended just above hemispheric level. Two depressions were below hemispheric level, of 9° at the anterior wall and of 21° along the posterosuperior wall. In 94% of all acetabula, the deepest extent of the articular surface was within 30° of the anterosuperior acetabular sector. In 99% of men and in 91% of women, the depth of the articular surface was at least 55° along almost half of the upper acetabular cup. The articular surface was smaller in women than in men. The acetabular opening plane was orientated in 21° ± 5° for version, 48° ± 4° for inclination and 19° ± 6° for acetabular tilt with no gender differences. We defined tilt as forward rotation of the entire acetabular cup around its central axis; because of interindividual variability of acetabular tilt, descriptions of acetabular lesions during surgery, CT scanning and MRI should be defined and recorded in relation to the acetabular notch. Acetabular tilt and pelvic tilt should be separately identified. We believe this information important for surgeons performing rim trimming in FAI surgery or performing acetabular osteotomies. PMID:19130159

  2. A novel electromagnetic navigation tool for acetabular surgery.

    PubMed

    Lehmann, Wolfgang; Rueger, Johannes M; Nuechtern, Jakob; Grossterlinden, Lars; Kammal, Michael; Hoffmann, Michael

    2015-10-01

    Acetabular fracture surgery is demanding and screw placement along narrow bony corridors remains challenging. It necessitates x-ray radiation for fluoroscopically assisted screw insertion. The purpose of this cadaver study was to evaluate the feasibility, accuracy and operation time of a novel electromagnetic navigation system for screw insertion along predefined acetabular corridors. A controlled laboratory study with a total of 24 electromagnetically navigated screw insertions was performed on 8 cadaveric acetabula. 3 peri-acetabular bony corridors (QSS, Quadrilateral Surface Screw; IAS, Infra-Acetabular Screw; PCS, Posterior Column Screw) were defined and screws were placed in a defined order without fluoroscopy. Operation time was documented. Postoperative CT scans were performed to analyse accuracy of screw placement. Mean cadaver age was 70.4 ± 11.7. Successful screw placement was accomplished in 22 out of 24 (91.7%) cases. The overall mean time for all 3 acetabular screws was 576.6 ± 75.9s. All 3 complications occurred during the placement of the IAS due to an impassable narrow bony corridor. QSS mean length was 50 ± 5mm, IAS mean length was 85 ± 10mm and PCS mean length was 120 ± 5mm. In this cadaver study the novel electromagnetic navigation system was feasible to allow accurate screw placement without fluoroscopy in defined narrow peri-acetabular bony corridors. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Discrete element analysis is a valid method for computing joint contact stress in the hip before and after acetabular fracture.

    PubMed

    Townsend, Kevin C; Thomas-Aitken, Holly D; Rudert, M James; Kern, Andrew M; Willey, Michael C; Anderson, Donald D; Goetz, Jessica E

    2018-01-23

    Evaluation of abnormalities in joint contact stress that develop after inaccurate reduction of an acetabular fracture may provide a potential means for predicting the risk of developing post-traumatic osteoarthritis. Discrete element analysis (DEA) is a computational technique for calculating intra-articular contact stress distributions in a fraction of the time required to obtain the same information using the more commonly employed finite element analysis technique. The goal of this work was to validate the accuracy of DEA-computed contact stress against physical measurements of contact stress made in cadaveric hips using Tekscan sensors. Four static loading tests in a variety of poses from heel-strike to toe-off were performed in two different cadaveric hip specimens with the acetabulum intact and again with an intentionally malreduced posterior wall acetabular fracture. DEA-computed contact stress was compared on a point-by-point basis to stress measured from the physical experiments. There was good agreement between computed and measured contact stress over the entire contact area (correlation coefficients ranged from 0.88 to 0.99). DEA-computed peak contact stress was within an average of 0.5 MPa (range 0.2-0.8 MPa) of the Tekscan peak stress for intact hips, and within an average of 0.6 MPa (range 0-1.6 MPa) for fractured cases. DEA-computed contact areas were within an average of 33% of the Tekscan-measured areas (range: 1.4-60%). These results indicate that the DEA methodology is a valid method for accurately estimating contact stress in both intact and fractured hips. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Open reduction and internal fixation of osteoporotic acetabular fractures through the ilio-inguinal approach: use of buttress plates to control medial displacement of the quadrilateral surface.

    PubMed

    Peter, Robin E

    2015-01-01

    The number of acetabular fractures in the geriatric population requiring open reduction and internal fixation is increasing. Fractures with medial or anterior displacement are the most frequent types, and via the ilio-inguinal approach buttress plates have proved helpful to maintain the quadrilateral surface or medial acetabular wall. Seven to ten hole 3.5 mm reconstruction plates may be used as buttress plates, placed underneath the usual pelvic brim plate. This retrospective study presents our results with this technique in 13 patients at a minimum follow-up of 12 months (average, 31 months). 85% of the patients had a good result. The early onset of post-traumatic osteoarthritis necessitated total hip arthroplasty in two patients (15%) at 12 and 18 months follow-up, respectively. This treatment option should be considered in the surgeon's armamentarium when fixing these challenging cases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Acetabular Cup Revision.

    PubMed

    Kim, Young-Ho

    2017-09-01

    The use of acetabular cup revision arthroplasty is on the rise as demands for total hip arthroplasty, improved life expectancies, and the need for individual activity increase. For an acetabular cup revision to be successful, the cup should gain stable fixation within the remaining supportive bone of the acetabulum. Since the patient's remaining supportive acetabular bone stock plays an important role in the success of revision, accurate classification of the degree of acetabular bone defect is necessary. The Paprosky classification system is most commonly used when determining the location and degree of acetabular bone loss. Common treatment options include: acetabular liner exchange, high hip center, oblong cup, trabecular metal cup with augment, bipolar cup, bulk structural graft, cemented cup, uncemented cup including jumbo cup, acetabular reinforcement device (cage), trabecular metal cup cage. The optimal treatment option is dependent upon the degree of the discontinuity, the amount of available bone stock and the likelihood of achieving stable fixation upon supportive host bone. To achieve successful acetabular cup revision, accurate evaluation of bone defect preoperatively and intraoperatively, proper choice of method of acetabular revision according to the evaluation of acetabular bone deficiency, proper technique to get primary stability of implant such as precise grafting technique, and stable fixation of implant are mandatory.

  6. Cup-cage construct for acute fractures of the acetabulum, re-defining indications.

    PubMed

    Chana-Rodríguez, Francisco; Villanueva-Martínez, Manuel; Rojo-Manaute, Jose; Sanz-Ruíz, Pablo; Vaquero-Martín, Javier

    2012-12-01

    Acetabular fractures in the elderly are challenging injuries. The use of a trabecular metal acetabular cage was investigated as the treatment option in a series of elderly patients with acetabular fractures. At a 2-year follow up, 6 elderly patients were found to have mimimum pain, increased function, and increased scores using the Merle d'Aubigné and Postel system modified by Charnley. Radiographically, the areas of morsellised autograft that surrounded the cups were seen to have incorporated uniformly well, and the acetabular fractures were healed within six months after surgery. No mechanical failure, screw breakage, loosening, or migration was noticed. This novel indication of the cup-cage construction that uses revision techniques, for selected patients and fractures, to achieve an acute stable reconstruction, should be considered as an alternative reconstruction option in elderly patients presenting with acetabular fractures. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. [IMAGING ANALYSIS OF ACETABULAR CUP POSITIONS IN TOTAL HIP ARTHROPLASTY FOR ADULTS WITH ACETABULAR DYSPLASIA].

    PubMed

    Sun, Hong; Fang, Shuying; Yang, Zibo; Zhang, Zhiqi; Kang, Yan; Zhang, Ziji; Liao, Weiming; Fu, Ming; Wu, Peihui

    2016-11-08

    To investigate the influence of the degree of acetabular deformity and the learning-curve on the acetabular cup positions in total hip arthroplasty (THA) for adults with developmental dysplasia of hip (DDH). Between January 2008 and December 2015, 130 patients (144 hips) with DDH underwent primary THA, and the clinical data were analyzed retrospectively. Fifty-three patients (59 hips) were admitted before 2012, and 77 patients (85 hips) were treated after 2012. There were 32 males and 98 females, aged from 31 to 83 years (mean, 61). Unilateral replacement was performed in 116 cases and bilateral replacement in 14 cases. Of 144 hips, 48 hips were rated as Crowe type I, 57 hips as type II, and 39 hips as type of III/IV. The standard pelvic radiograph was taken within 1 week after operation. The mediCAD software was adopted to measure the angle of anteversion and abduction, bony coverage, and the distance between true rotating center and optimal rotating center to the connection of teardrops and the horizontal distance between two centers to evaluate the qualified rate of acetabular cup positions. Compared with the patients with the same type in 2013-2015 group, the anteversion angle and qualified rate of acetabular cup position significantly decreased in patients with Crowe I ( P <0.05); the horizontal distance significantly increased and qualified rate of acetabular cup position significantly decreased in patients with Crowe II ( P <0.05); and the anteversion angle significantly decreased and the horizontal distance significantly increased in patients with Crowe III/IV ( P <0.05) in 2008-2012 group. But no significant difference was shown in the other indexes ( P >0.05). In all Crowe types, the vertical distance between the true rotating center and the optimal rotating center increased with the degree of acetabular deformity in both 2008-2012 group and 2013-2015 group, showing significant difference ( P <0.05), but no significant difference was found in the other

  8. Use of a constrained tripolar acetabular liner to treat intraoperative instability and postoperative dislocation after total hip arthroplasty: a review of our experience.

    PubMed

    Callaghan, John J; O'Rourke, Michael R; Goetz, Devon D; Lewallen, David G; Johnston, Richard C; Capello, William N

    2004-12-01

    Constrained acetabular components have been used to treat certain cases of intraoperative instability and postoperative dislocation after total hip arthroplasty. We report our experience with a tripolar constrained component used in these situations since 1988. The outcomes of the cases where this component was used were analyzed for component failure, component loosening, and osteolysis. At average 10-year followup, for cases treated for intraoperative instability (2 cases) or postoperative dislocation (4 cases), the component failure rate was 6% (6 of 101 hips in 5 patients). For cases where the constrained liner was cemented into a fixed cementless acetabular shell, the failure rate was 7% (2 of 31 hips in 2 patients) at 3.9-year average followup. Use of a constrained liner was not associated with an increased osteolysis or aseptic loosening rate. This tripolar constrained acetabular liner provided total hip arthroplasty construct stability in most cases in which it was used for intraoperative instability or postoperative dislocation.

  9. Intraoperative assessment of reduction and implant placement in acetabular fractures-limitations of 3D-imaging compared to computed tomography.

    PubMed

    Keil, Holger; Beisemann, Nils; Schnetzke, Marc; Vetter, Sven Yves; Swartman, Benedict; Grützner, Paul Alfred; Franke, Jochen

    2018-04-10

    In acetabular fractures, the assessment of reduction and implant placement has limitations in conventional 2D intraoperative imaging. 3D imaging offers the opportunity to acquire CT-like images and thus to improve the results. However, clinical experience shows that even 3D imaging has limitations, especially regarding artifacts when implants are placed. The purpose of this study was to assess the difference between intraoperative 3D imaging and postoperative CT regarding reduction and implant placement. Twenty consecutive cases of acetabular fractures were selected with a complete set of intraoperative 3D imaging and postoperative CT data. The largest detectable step and the largest detectable gap were measured in all three standard planes. These values were compared between the 3D data sets and CT data sets. Additionally, possible correlations between the possible confounders age and BMI and the difference between 3D and CT values were tested. The mean difference of largest visible step between the 3D imaging and CT scan was 2.0 ± 1.8 mm (0.0-5.8, p = 0.02) in the axial, 1.3 ± 1.4 mm (0.0-3.7, p = 0.15) in the sagittal and 1.9 ± 2.4 mm (0.0-7.4, p = 0.22) in the coronal views. The mean difference of largest visible gap between the 3D imaging and CT scan was 3.1 ± 3.6 mm (0.0-14.1, p = 0.03) in the axial, 4.6 ± 2.7 mm (1.2-8.7, p = 0.001) in the sagittal and 3.5 ± 4.0 mm (0.0-15.4, p = 0.06) in the coronal views. A positive correlation between the age and the difference in gap measurements in the sagittal view was shown (rho = 0.556, p = 0.011). Intraoperative 3D imaging is a valuable adjunct in assessing reduction and implant placement in acetabular fractures but has limitations due to artifacts caused by implant material. This can lead to missed malreduction and impairment of clinical outcome, so postoperative CT should be considered in these cases.

  10. Biomechanical modeling of acetabular component polyethylene stresses, fracture risk, and wear rate following press-fit implantation.

    PubMed

    Ong, Kevin L; Rundell, Steve; Liepins, Imants; Laurent, Ryan; Markel, David; Kurtz, Steven M

    2009-11-01

    Press-fit implantation may result in acetabular component deformation between the ischial-ilial columns ("pinching"). The biomechanical and clinical consequences of liner pinching due to press-fit implantation have not been well studied. We compared the effects of pinching on the polyethylene fracture risk, potential wear rate, and stresses for two different thickness liners using computational methods. Line-to-line ("no pinch") reaming and 2 mm underreaming press fit ("pinch") conditions were examined for Trident cups with X3 polyethylene liner wall thicknesses of 5.9 mm (36E) and 3.8 mm (40E). Press-fit cup deformations were measured from a foam block configuration. A hybrid material model, calibrated to experimentally determined stress-strain behavior of sequentially annealed polyethylene, was applied to the computational model. Molecular chain stretch did not exceed the fracture threshold in any cases. Nominal shell pinch of 0.28 mm was estimated to increase the volumetric wear rate by 70% for both cups and peak contact stresses by 140 and 170% for the 5.9 and 3.8 mm-thick liners, respectively. Although pinching increases liner stresses, polyethylene fracture is highly unlikely, and the volumetric wear rates are likely to be low compared to conventional polyethylene. (c) 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  11. Inversion of the acetabular labrum triggers rapidly destructive osteoarthritis of the hip: representative case report and proposed etiology.

    PubMed

    Fukui, Kiyokazu; Kaneuji, Ayumi; Fukushima, Mana; Matsumoto, Tadami

    2014-12-01

    The pathophysiology of rapidly destructive osteoarthritis (OA) of the hip is unknown. This study documented cases of inversion of the acetabular labrum, which has clinicoradiologic features similar to those of initial-stage rapidly destructive hip OA. Our study was based on a prospective review of data for 9 patients with rapidly destructive hip OA. Intraoperative findings showed that the anterosuperior portion of the acetabular labrum had inverted into the articular space, along with many fragments of articular cartilage, in all patients. Subchondral insufficiency fractures of the femoral heads were seen just under the inverted labra in 8 of the 9 patients. Inversion of the acetabular labrum may be involved in rapid joint-space narrowing and subchondral insufficiency fracture in rapidly destructive hip OA. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Functional outcomes of conservatively treated clavicle fractures

    PubMed Central

    Bajuri, Mohd Yazid; Maidin, S; Rauf, A; Baharuddin, M; Harjeet, S

    2011-01-01

    OBJECTIVE: The main aim of the study was to analyze the outcomes of clavicle fractures in adults treated non-surgically and to evaluate the clinical effects of displacement, fracture patterns, fracture location, fracture comminution, shortening and fracture union on shoulder function. METHODS: Seventy clavicle fractures were non-surgically treated in the Orthopedics Department at the Tuanku Ja'afar General Hospital, a tertiary care hospital in Seremban, Malaysia, an average of six months after injury. The clavicle fractures were treated conservatively with an arm sling and a figure-eight splint for three weeks. No attempt was made to reduce displaced fractures, and the patients were allowed immediate free-shoulder mobilization, as tolerated. They were prospectively evaluated clinically and radiographically. Shoulder function was evaluated using the Constant scoring technique. RESULTS: There were statistically significant functional outcome impairments in non-surgically treated clavicle fractures that correlated with the fracture type (comminution), the fracture displacement (21 mm or more), shortening (15 mm or more) and the fracture union (malunion). CONCLUSION: This article reveals the need for surgical intervention to treat clavicle fractures and improve shoulder functional outcomes. PMID:21655759

  13. Fractures of a single design of highly cross-linked polyethylene acetabular liners: an analysis of voluntary reports to the United States Food and Drug Administration.

    PubMed

    Ast, Michael P; John, Thomas K; Labbisiere, Anthony; Robador, Nicolas; Valle, Alejandro Gonzalez Della

    2014-06-01

    Polyethylene liner fracture is a risk associated with the use of highly cross-linked UHMWPE. We performed a review of the voluntary reports of fractured liners to the US Food and Drug Administration to determine if any risk factors could be identified. There have been 74 reports of fractured Trilogy, Longevity liners to the US Food and Drug Administration since 1999. Most cases utilized small acetabular shells (≤54 mm) combined with large diameter heads (≥36 mm). Liners less than 7 mm thick at the weight bearing or 4.8 mm thick at the rim should be used with caution. At revision surgery, malpositioned shells should be revised and the use of a thin liner should be avoided. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. The design, production and clinical application of 3D patient-specific implants with drilling guides for acetabular surgery.

    PubMed

    Merema, B J; Kraeima, J; Ten Duis, K; Wendt, K W; Warta, R; Vos, E; Schepers, R H; Witjes, M J H; IJpma, F F A

    2017-11-01

    An innovative procedure for the development of 3D patient-specific implants with drilling guides for acetabular fracture surgery is presented. By using CT data and 3D surgical planning software, a virtual model of the fractured pelvis was created. During this process the fracture was virtually reduced. Based on the reduced fracture model, patient-specific titanium plates including polyamide drilling guides were designed, 3D printed and milled for intra-operative use. One of the advantages of this procedure is that the personalised plates could be tailored to both the shape of the pelvis and the type of fracture. The optimal screw directions and sizes were predetermined in the 3D model. The virtual plan was translated towards the surgical procedure by using the surgical guides and patient-specific osteosynthesis. Besides the description of the newly developed multi-disciplinary workflow, a clinical case example is presented to demonstrate that this technique is feasible and promising for the operative treatment of complex acetabular fractures. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Correlation of Hip Fracture with Other Fracture Types: Toward a Rational Composite Hip Fracture Endpoint

    PubMed Central

    Colón-Emeric, Cathleen; Pieper, Carl F.; Grubber, Janet; Van Scoyoc, Lynn; Schnell, Merritt L; Van Houtven, Courtney Harold; Pearson, Megan; Lafleur, Joanne; Lyles, Kenneth W.; Adler, Robert A.

    2016-01-01

    Purpose With ethical requirements to the enrollment of lower risk subjects, osteoporosis trials are underpowered to detect reduction in hip fractures. Different skeletal sites have different levels of fracture risk and response to treatment. We sought to identify fracture sites which cluster with hip fracture at higher than expected frequency; if these sites respond to treatment similarly, then a composite fracture endpoint could provide a better estimate of hip fracture reduction. Methods Cohort study using Veterans Affairs and Medicare administrative data. Male Veterans (n=5,036,536) aged 50-99 years receiving VA primary care between1999-2009 were included. Fractures were ascertained using ICD9 and CPT codes and classified by skeletal site. Pearson correlation coefficients, logistic regression and kappa statistics, were used to describe the correlation between each fracture type and hip fracture within individuals, without regards to the timing of the events. Results 595,579 (11.8%) men suffered 1 or more fractures and 179,597 (3.6%) suffered 2 or more fractures during the time under study. Of those with one or more fractures, rib was the most common site (29%), followed by spine (22%), hip (21%) and femur (20%). The fracture types most highly correlated with hip fracture were pelvic/acetabular (Pearson correlation coefficient 0.25, p<0.0001), femur (0.15, p<0.0001), and shoulder (0.11, p<0.0001). Conclusions Pelvic, acetabular, femur, and shoulder fractures cluster with hip fractures within individuals at greater than expected frequency. If we observe similar treatment risk reductions within that cluster, subsequent trials could consider use of a composite endpoint to better estimate hip fracture risk. PMID:26151123

  16. Nanotechnology for treating osteoporotic vertebral fractures

    PubMed Central

    Gao, Chunxia; Wei, Donglei; Yang, Huilin; Chen, Tao; Yang, Lei

    2015-01-01

    Osteoporosis is a serious public health problem affecting hundreds of millions of aged people worldwide, with severe consequences including vertebral fractures that are associated with significant morbidity and mortality. To augment or treat osteoporotic vertebral fractures, a number of surgical approaches including minimally invasive vertebroplasty and kyphoplasty have been developed. However, these approaches face problems and difficulties with efficacy and long-term stability. Recent advances and progress in nanotechnology are opening up new opportunities to improve the surgical procedures for treating osteoporotic vertebral fractures. This article reviews the improvements enabled by new nanomaterials and focuses on new injectable biomaterials like bone cements and surgical instruments for treating vertebral fractures. This article also provides an introduction to osteoporotic vertebral fractures and current clinical treatments, along with the rationale and efficacy of utilizing nanomaterials to modify and improve biomaterials or instruments. In addition, perspectives on future trends with injectable bone cements and surgical instruments enhanced by nanotechnology are provided. PMID:26316746

  17. Early failure mechanisms of constrained tripolar acetabular sockets used in revision total hip arthroplasty.

    PubMed

    Cooke, Christopher C; Hozack, William; Lavernia, Carlos; Sharkey, Peter; Shastri, Shani; Rothman, Richard H

    2003-10-01

    Fifty-eight patients received an Osteonics constrained acetabular implant for recurrent instability (46), girdlestone reimplant (8), correction of leg lengthening (3), and periprosthetic fracture (1). The constrained liner was inserted into a cementless shell (49), cemented into a pre-existing cementless shell (6), cemented into a cage (2), and cemented directly into the acetabular bone (1). Eight patients (13.8%) required reoperation for failure of the constrained implant. Type I failure (bone-prosthesis interface) occurred in 3 cases. Two cementless shells became loose, and in 1 patient, the constrained liner was cemented into an acetabular cage, which then failed by pivoting laterally about the superior fixation screws. Type II failure (liner locking mechanism) occurred in 2 cases. Type III failure (femoral head locking mechanism) occurred in 3 patients. Seven of the 8 failures occurred in patients with recurrent instability. Constrained liners are an effective method for treatment during revision total hip arthroplasty but should be used in select cases only.

  18. Promising Mid-term Results With a Cup-cage Construct for Large Acetabular Defects and Pelvic Discontinuity.

    PubMed

    Amenabar, Tomas; Rahman, Wael A; Hetaimish, Bandar M; Kuzyk, Paul R; Safir, Oleg A; Gross, Allan E

    2016-02-01

    Restoring normal anatomy and achieving stable fixation of the acetabular component can be especially challenging when the surgeon must deal with severe acetabular defects and/or pelvic discontinuity. The cup-cage (CC) construct, where an ilioischial cage is cemented within a biologically fixed porous metal cup, has emerged as an excellent option to treat such challenges. We sought to determine (1) mid-term Kaplan-Meier survival; (2) clinical outcomes based on Merle d'Aubigné-Postel scores; (3) radiological outcomes based primarily on construct migration; and (4) the complication rate for a series of 67 CC procedures performed at our institution. All hip revision procedures between January 2003 and March 2012 where a CC was used (with the exception of tumor cases or acute fracture; four total cases) that had a minimum 2-year followup and that had been seen within the last 2 years were included in this retrospective review. Acetabular bone loss and presence of pelvic discontinuity were assessed according to the Gross classification. Sixty-seven CC procedures with an average followup of 74 months (range, 24-135 months; SD, 34.3) months were identified; 26 of 67 (39%) were Gross Type IV and 41 of 67 (61%) were Gross Type V (pelvic discontinuity). Postoperative clinical and radiological evaluation was done annually. Merle d'Aubigné-Postel scores were recorded and all radiographs were compared with the 6-week postoperative radiographs to evaluate for radiographic loosening or migration. Failure was defined as revision surgery for any cause, including infection. The 5-year Kaplan-Meier survival rate with revision for any cause representing failure was 93% (95% confidence interval [CI], 83.1-97.4), and the 10-year survival rate was 85% (95% CI, 67.2-93.8). The Merle d'Aubigné-Postel score improved significantly from a mean of 6 preoperatively to 13 postoperatively (p < 0.001). Four CC had nonprogressive radiological migration of the ischial flange and they remain stable

  19. Periprosthetic Occult Fractures of the Acetabulum Occur Frequently During Primary THA.

    PubMed

    Hasegawa, Kazuhiro; Kabata, Tamon; Kajino, Yoshitomo; Inoue, Daisuke; Tsuchiya, Hiroyuki

    2017-02-01

    cup, and acetabular design were examined in multivariate analysis. Acetabular component designs were categorized as true hemispheric, peripheral self-locking, and elliptical; during the period in question the indications for each cup design were based on the brand of stem used. Comparison between preoperative and postoperative CT images was done to detect the fractures. Patients with fractures identified during surgery were treated with additional dome screw fixation and a 3-week period of nonweightbearing. Patients with occult fractures in this series did not receive additional treatment as we had confirmed secure fixation of the cup during surgery. Occult fractures occurred in 41 hips (8.4%); periprosthetic fractures of the acetabulum were seen during surgery in an additional two hips (0.4%). The superolateral wall was the most frequent location for occult fractures of the acetabulum. After controlling for relevant confounding variables, only the use of peripheral self-locking cups was associated with an increased risk of occult fracture (odds ratio [OR], 2.6 compared with hemispheric cups; 95% CI, 1.2-5.6; p < 0.05). All patients with occult fractures showed bone ingrowth fixation at the final followup, without any additional surgical intervention. Periprosthetic occult fractures of the acetabulum may occur relatively frequently during press-fit impaction. We observed a higher rate of fractures associated with the use of peripheral self-locking components. Occult acetabular fractures not detected on routine postoperative plain films may be ignored if secure fixation of the cup has been confirmed during the operation. Level III, therapeutic study.

  20. Does a cemented cage improve revision THA for severe acetabular defects?

    PubMed

    Hansen, Erik; Shearer, David; Ries, Michael D

    2011-02-01

    Evidence suggests a growing incidence of revision total hip arthroplasty (THA) including a subset with large acetabular defects. Revision THA for severe acetabular bone loss is associated with a relatively high rate of mechanical failure. We questioned whether cementing a cage to the reconstructed acetabular defect and pelvis would improve the rate of mechanical failure for patients with Type 3 defects (Paprosky et al.) with and without pelvic discontinuity in comparison to historical controls. We retrospectively collected data on 33 patients who underwent 35 revision THAs using an acetabular reconstruction cage cemented to morselized allograft and either structural allograft or trabecular metal augmentation for Type 3 defects in the presence (n = 13) and absence (n = 22) of pelvic discontinuity at a mean followup of 59 months (range, 24-92 months). The primary outcome was mechanical failure, defined as revision of the acetabular reconstruction for aseptic loosening. Revision surgery for mechanical failure occurred in four of the 13 patients with pelvic discontinuity and two of the 22 patients without discontinuity. Radiographic loosening occurred in one patient with and one patient without pelvic discontinuity. Seven of the 35 revisions were subsequently revised for deep infection all in patients who were immunocompromised. Cementing the cage to the pelvis can offer an advantage for treating severe acetabular defects. Trabecular metal augmentation appears to provide better initial mechanical stability than a structural allograft, but successful allograft reconstruction may restore bone stock. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  1. The jumbo acetabular component for acetabular revision: Curtain Calls and Caveats.

    PubMed

    Lachiewicz, P F; Watters, T S

    2016-01-01

    The 'jumbo' acetabular component is now commonly used in acetabular revision surgery where there is extensive bone loss. It offers high surface contact, permits weight bearing over a large area of the pelvis, the need for bone grafting is reduced and it is usually possible to restore centre of rotation of the hip. Disadvantages of its use include a technique in which bone structure may not be restored, a risk of excessive posterior bone loss during reaming, an obligation to employ screw fixation, limited bone ingrowth with late failure and high hip centre, leading to increased risk of dislocation. Contraindications include unaddressed pelvic dissociation, inability to implant the component with a rim fit, and an inability to achieve screw fixation. Use in acetabulae with < 50% bone stock has also been questioned. Published results have been encouraging in the first decade, with late failures predominantly because of polyethylene wear and aseptic loosening. Dislocation is the most common complication of jumbo acetabular revisions, with an incidence of approximately 10%, and often mandates revision. Based on published results, a hemispherical component with an enhanced porous coating, highly cross-linked polyethylene, and a large femoral head appears to represent the optimum tribology for jumbo acetabular revisions. ©2016 The British Editorial Society of Bone & Joint Surgery.

  2. Hemodynamic Deterioration in Lateral Compression Pelvic Fracture After Prehospital Pelvic Circumferential Compression Device Application.

    PubMed

    Garner, Alan A; Hsu, Jeremy; McShane, Anne; Sroor, Adam

    Increased fracture displacement has previously been described with the application of pelvic circumferential compression devices (PCCDs) in patients with lateral compression-type pelvic fracture. We describe the first reported case of hemodynamic deterioration temporally associated with the prehospital application of a PCCD in a patient with a complex acetabular fracture with medial displacement of the femoral head. Active hemorrhage from a site adjacent to the acetabular fracture was subsequently demonstrated on angiography. Caution in the application of PCCDs to patients with lateral compression-type fractures is warranted. Copyright © 2017 Air Medical Journal Associates. All rights reserved.

  3. Extruded talus treated with reimplantation and primary tibiotalocalcaneal arthrodesis

    PubMed Central

    A’Court, J; Pillai, A

    2017-01-01

    Extruded talus is a rare serious result from a high-energy injury to a supinated and plantar flexed foot. Treatment remains controversial with a lack of congruent evidence for talar reimplantation. A 34-year-old woman was involved in a road traffic accident at 40 mph. Imaging revealed a left talus extruded anterolaterally with a talar neck fracture. Additional injuries included right acetabular fracture, transverse process fractures and rib fractures, which were treated conservatively. The talus was reimplanted and the talar neck fixed with a cortical screw. A hindfoot nail was used to fuse the calcaneus, talus and tibia. Follow-up at two years showed solid tibiotalocalcaneal fusion, with no evidence of avascular development, and the patient was fully weight bearing without pain. We believe this is the first published case of successful primary tibiotalocalcaneal fusion for extruded talus injuries. PMID:28349756

  4. An unusual mode of failure of a tripolar constrained acetabular liner: a case report.

    PubMed

    Banks, Louisa N; McElwain, John P

    2010-04-01

    Dislocation after primary total hip arthroplasty (THA) is the most commonly encountered complication and is unpleasant for both the patient and the surgeon. Constrained acetabular components can be used to treat or prevent instability after primary total hip arthroplasty. We present the case of a 42-year-old female with a BMI of 41. At 18 months post-primary THA the patient underwent further revision hip surgery after numerous (more than 20) dislocations. She had a tripolar Trident acetabular cup (Stryker-Howmedica-Osteonics, Rutherford, New Jersey) inserted. Shortly afterwards the unusual mode of failure of the constrained acetabular liner was noted from radiographs in that the inner liner had dissociated from the outer. The reinforcing ring remained intact and in place. We believe that the patient's weight, combined with poor abductor musculature caused excessive demand on the device leading to failure at this interface when the patient flexed forward. Constrained acetabular components are useful implants to treat instability but have been shown to have up to 42% long-term failure rates with problems such as dissociated inserts, dissociated constraining rings and dissociated femoral rings being sited. Sometimes they may be the only option left in difficult cases such as illustrated here, but still unfortunately have the capacity to fail in unusual ways.

  5. Periacetabular Osteotomy Provides Higher Survivorship Than Rim Trimming for Acetabular Retroversion.

    PubMed

    Zurmühle, Corinne A; Anwander, Helen; Albers, Christoph E; Hanke, Markus S; Steppacher, Simon D; Siebenrock, Klaus A; Tannast, Moritz

    2017-04-01

    Acetabular retroversion can cause impaction-type femoroacetabular impingement leading to hip pain and osteoarthritis. It can be treated by anteverting periacetabular osteotomy (PAO) or acetabular rim trimming with refixation of the labrum. There is increasing evidence that acetabular retroversion is a rotational abnormality of the entire hemipelvis and not a focal overgrowth of the anterior acetabular wall, which favors an anteverting PAO. However, it is unknown if this larger procedure would be beneficial in terms of survivorship and Merle d'Aubigné scores in a midterm followup compared with rim trimming. We asked if anteverting PAO results in increased survivorship of the hip compared with rim trimming through a surgical hip dislocation in patients with symptomatic acetabular retroversion. We performed a retrospective, comparative study evaluating the midterm survivorship of two matched patient groups with symptomatic acetabular retroversion undergoing either anteverting PAO or acetabular rim trimming through a surgical hip dislocation. Acetabular retroversion was defined by a concomitantly present positive crossover, posterior wall, and ischial spine sign. A total of 279 hips underwent a surgical intervention for acetabular retroversion at our center between 1997 and 2012 (166 periacetabular osteotomies, 113 rim trimmings through surgical hip dislocation). A total of 99 patients (60%) were excluded from the PAO group and 56 patients (50%) from the rim trimming group because they had any of several prespecified conditions (eg, dysplasia or pediatric conditions 61 [37%] for the PAO group and two [2%] for the rim trimming group), matching (10 [6%]/10 [9%] hips), deficient records (10 [6%]/13 [12%] hips), or the patient declined or was lost to followup (18 [11%]/31 [27%] hips). This left 67 hips (57 patients) that underwent anteverting PAO and 57 hips (52 patients) that had acetabular rim trimming. The two groups did not differ in terms of age, sex, body mass

  6. Predictors for Long-Term Hip Survivorship Following Acetabular Fracture Surgery: Importance of Gap Compared with Step Displacement.

    PubMed

    Verbeek, Diederik O; van der List, Jelle P; Tissue, Camden M; Helfet, David L

    2018-06-06

    Historically, the greatest residual (gap or step) displacement is used to predict clinical outcome following acetabular fracture surgery. Gap and step displacement may, however, impact the outcome to different degrees. We assessed the individual relationship between gap or step displacement and hip survivorship and determined their independent association with conversion to total hip arthroplasty. Patients who had acetabular fracture fixation (from 1992 through 2014), follow-up of ≥2 years (or early conversion to total hip arthroplasty), and postoperative computed tomography (CT) scans were included. Of 227 patients, 55 (24.2%) had conversion to total hip arthroplasty at a mean follow-up (and standard deviation) of 8.7 ± 5.6 years. Residual gap and step displacement were measured using a standardized CT-based method, and assessors were blinded to the outcome. Kaplan-Meier survivorship curves for the hips were plotted and compared (log-rank test) using critical cutoff values for gap and step displacement. These values were identified using receiver operating characteristic curves. Multivariate analysis was performed to identify independent variables associated with conversion to total hip arthroplasty. Subgroup analysis was performed in younger patients (<50 years old). The critical CT cutoff value for total hip arthroplasty conversion was 5 mm for gap and 1 mm for step displacement. Hip survivorship at 10 years was 82.0% for patients with a gap of <5 mm compared with 56.5% for a gap of ≥5 mm (p < 0.001) and 80.0% for a step of <1.0 mm versus 65.5% for a step of ≥1.0 mm (p = 0.012). A gap of ≥5 mm (hazard ratio [HR], 2.3; p = 0.012) and an age of ≥50 years (HR, 4.2; p < 0.001) were independently associated with conversion to total hip arthroplasty in all patients. In the subgroup of younger patients, only a step of ≥1 mm (HR, 6.4; p = 0.017) was an independent factor for conversion to total hip arthroplasty. Residual gap and step displacement as

  7. [Return to Work after Fractures of the Pelvis and the Acetabulum].

    PubMed

    Nusser, M; Holstiege, J; Kaluscha, R; Tepohl, L; Stuby, F; Röderer, G; Krischak, G

    2015-06-01

    Pelvic and acetabular fractures are severe injuries with serious consequences that mainly happen to young people. Therefore it is highly interesting to find out to what extent affected patients succeed in returning to work, which is an important factor concerning quality of live. Thus, the objective of this study was to estimate the "return to work" in a two-year follow-up after rehabilitative treatment of patients with pelvic and acetabular fractures and to identify influencing factors. A retrospective cohort study was conducted using population-based administrative data of the Baden-Württemberg statutory pension fund. All patients (age 18 to 63 years) who had participated in a rehabilitation programme between 2004 and 2009 due to a pelvic or acetabular fracture were included. Return to work was modelled using multivariate logistic regression analysis. Rehabilitants were classified as "returned" if they have paid at least one monthly contribution due to employment during 13 to 24 months after rehabilitation. Age, gender, diagnostic group, type of rehabilitation programme, fractures of the spine, nerve injuries of the lumbosacral area and/or the lower limb and employment status before the fractures were considered as prognostic covariates. Two-thirds of the 249 researched patients returned to work. This corresponds to a reduction of employment amounting to 16.6 % for patients with a pelvic fracture and 20.8 % for patients with an acetabular fracture. Main predictor for a return to work was the employment status before the fracture. Younger patients had a better chance to return to work than older ones. Patients with fractures of the spine or nerve injuries of the lumbosacral area and/or the lower limb had a 73 % or, respectively, 78 % higher risk of not returning to work. Fractures of the pelvis and the acetabulum currently lead in one of five patients to loss of employment. Thereby the trauma threatens the social security of the young patients. Follow

  8. Interprosthetic femoral fractures treated with locking plate.

    PubMed

    Ebraheim, Nabil; Carroll, Trevor; Moral, Muhammad Z; Lea, Justin; Hirschfeld, Adam; Liu, Jiayong

    2014-10-01

    Interprosthetic fractures are challenging to manage. Although treatment of femoral fractures around a single implant has been described, there is little literature for treatment of interprosthetic femoral fractures. This study analyses the management and outcomes of 15 patients with interprosthetic femoral fractures treated with locking plates. A retrospective chart review was conducted of 17 patients with interprosthetic femur fracture treated with locking plates from 2002 to 2013. Patient demographics and comorbidities were collected. Preoperatively, patients were classified with the Vancouver or Su classification system. Intraoperative use of bone graft and/or cerclage cables was also examined. Clinical and radiographic outcomes were evaluated for union, time to full weight bearing, return to preinjury level of activity, and pain assessed with visual analog scale (VAS). There were 15 patients with interprosthetic fractures meeting criteria for this study. Average patient age was 80.53 (range, 61-92) years. Bone grafting was used in 23.5% (four of 17) and cerclage cables in 29.4% (five of 17). Patients achieved complete union and return to full weight bearing an average of 4.02 (range, two to six) months later. Average VAS pain score was 1.00 (range, zero to six). All patients returned to their preoperative ambulatory status. Locking plates could achieve satisfactory results for interprosthetic fractures. Considering an individual's fracture type, bone quality and protheses to determine the appropriate plate length and optional use of cerclage and/or bone graft was essential. In this limited sample size, interprosthetic fractures occurred at similar rates at the supracondylar region and diaphysis.

  9. Pediatric mandibular fractures treated by rigid internal fixation.

    PubMed

    Wong, G B

    1993-09-01

    Mandibular fractures in the pediatric patient population are relatively uncommon. These patients present with their own unique treatment requirements. Most fractures have been treated conservatively by dental splints. Closed reduction techniques with maxillomandibular fixation (MMF) in very young children can pose several concerns, including cooperation, compliance and adequate nutritional intake. Rigid internal fixation of unstable mandibular fractures using miniplates and screws circumvents the need for MMF and allows immediate jaw mobilization. At major pediatric trauma institutions, there has been an increasing trend toward the use of this treatment when open reduction is necessary. This article presents a report of a five-year-old child who presented with bilateral mandibular fractures and was treated by rigid internal fixation and immediate mandibular mobilization.

  10. A case report of the management and the outcome of a complete epiphyseal separation and dislocation with left anterior column fracture of the acetabulum.

    PubMed

    Palencia, Jesús; Alfayez, Saud; Serro, Firas; Alqahtani, Jamal; Alharbi, Hani; Alhinai, Hamed

    2016-01-01

    Femoral head and neck fractures in children are uncommon, accounting for fewer than 1% of all pediatric fractures and fewer than 8% of all hip fractures. Furthermore, traumatic transphyseal hip fracture is rare to present in daily practice especially when associated with an acetabular fracture. A twelve years old boy, not known to have any chronic illnesses, presented to the emergency department as a case of polytrauma after a road traffic accident. Signs of left hip dislocation were discovered upon physical examination. X-rays and CT scans, revealed a complete transphyseal posterior dislocation and a left anterior column fracture of the acetabulum with a minimal displacement. Within five hours, the patient underwent open reduction and internal fixation by two cannulated screws. The acetabular fracture was managed conservatively. After six months, there were clear signs of osteonecrosis of the femoral head. A high-energy trauma in children and adolescents can lead to simultaneous epiphyseal and acetabular fractures which are associated with a poor prognosis. The age seems to play a role as patients older than ten years have a higher risk of developing AVN after sustaining a hip dislocation regardless of the time of intervention. Epiphyseal fracture with dislocation of the femoral head is rare among children and adolescents, especially when associated with an acetabular fracture. AVN in such cases can develop, and it represents a challenge to orthopedic surgeons due to the poor prognosis and the future functional limitations of the joint. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  11. The Evolution of the Cup-Cage Technique for Major Acetabular Defects: Full and Half Cup-Cage Reconstruction.

    PubMed

    Sculco, Peter K; Ledford, Cameron K; Hanssen, Arlen D; Abdel, Matthew P; Lewallen, David G

    2017-07-05

    Complex acetabular reconstruction for major bone loss can require advanced methods such as the use of a cup-cage construct. The purpose of this study was to review outcomes after the initial development of the cup-cage technique and the subsequent evolution to the use of a half cup-cage construct. We performed a retrospective, single-center review of 57 patients treated with cup-cage reconstruction for major acetabular bone loss. All patients had major acetabular defects graded as Paprosky Type 2B through 3B, with 34 (60%) having an associated pelvic discontinuity. Thirty patients received a full cup-cage construct and 27, a half cup-cage construct. The mean follow-up was 5 years. Both the full and half cup-cage cohorts demonstrated significantly improved Harris hip score (HHS) values, from 36 to 72 at a minimum of 2 years of follow-up (p < 0.05). Early construct migration occurred in 4 patients, with stabilization prior to 2-year follow-up in all but 1 patient. Incomplete, zone-3, nonprogressive acetabular radiolucencies were observed in 2 (7%) of the full cup-cage constructs and 6 (22%) of the half cup-cage constructs. One patient with a full cup-cage construct underwent re-revision of the acetabular component for progressive migration and aseptic loosening. Short-term survivorship free from re-revision for any cause or reoperation was 89% (83% and 96% for full and half cup-cage cohorts, respectively). Both full and half cup-cage constructs demonstrated successful clinical outcomes and survivorship in the treatment of major acetabular defects and pelvic discontinuity. Each method is utilized on the basis of individual intraoperative findings, including the extent and pattern of bone loss, the quality and location of host bone remaining after preparation, and the presence of pelvic discontinuity. Longer-term follow-up is required to understand the durability of these constructs in treating major acetabular defects and pelvic discontinuity. Therapeutic Level III

  12. Nonsurgical Treatment of Acetabular Labral Tears.

    PubMed

    Theige, Melissa; David, Shannon

    2018-05-04

    Clinical Scenario: Surgical treatment of acetabular labral tears has been explored in multiple studies, while there is a lack of research on the effectiveness of conservative methods. Focused Clinical Question: To what extent can nonsurgical treatment produce symptomatic or functional improvements in athletes with an acetabular labral tear? Summary of Search, Best Evidence Appraised, and Key Findings: The literature was searched for studies of patients with confirmed acetabular labral tears who participated in any level of sport. Four studies were located, all of which were included. Clinical Bottom Line: The research discussed in this review agreed that conservative management of acetabular labral tears produced measurable improvements in pain and function among the athletes studied, including their ability to participate in sport activities. Based on these findings, it appears that conservative management is effective at rehabilitating athletes with acetabular labral tears. However, this method should not be applied to every athlete based on the low strength of current research. Treatment plans should be decided upon on a case-by-case basis. Strength of Recommendation: The studies located were of low quality. The highest Oxford Center for Evidence-Based Medicine Level of Evidence achieved was 4. Higher level studies must be conducted before the conclusions of this research can be applied clinically with assertion. Strength of recommendation is level 3.

  13. Stress Fractures of Tibia Treated with Ilizarov External Fixator.

    PubMed

    Górski, Radosław; Żarek, Sławomir; Modzelewski, Piotr; Górski, Ryszard; Małdyk, Paweł

    2016-08-30

    Stress fractures are the result of cyclic loading of the bone, which gradually becomes damaged. Most often they are treated by rest or plaster cast and, in rare cases, by internal fixation. There is little published data on initial reposition followed by stabilization with the Ilizarov apparatus in such fractures. Six patients were treated with an external fixator according to the Ilizarov method for a stress fracture of the tibia between 2007 and 2015. Three patients were initially treated conservatively. Due to increasing tibial deformation, they were qualified for surgical treatment with external stabilization. In the other patients, surgery was the first-line treatment. All patients demonstrated risk factors for a stress fracture. After the surgery, they fully loaded the operated limb. No patient developed malunion, nonunion, infection or venous thrombosis. The average time from the first operation to the removal of the external fixator was 19 weeks. Radiographic and clinical outcomes were satisfactory in all patients. 1. The Ilizarov method allows for successful stabilization of stress fractures of the tibia. 2. It may be a good alternative to internal stabilization, especially in patients with multiple comorbidities which affect bone quality and may impair soft tissue healing.

  14. [Stress analysis on the acetabular side of bipolar hemiarthroplasty by the two-dimensional finite element method incorporating the boundary friction layer].

    PubMed

    Ichihashi, K; Imura, S; Oomori, H; Gesso, H

    1994-11-01

    We compared the biomechanical characteristics of bipolar and unipolar hemiarthroplasty on the proximal migration of the outer head by determining the von Mises stress distribution and acetabular (outer head) displacement with clinical assessment of hemiarthroplasty in 75 patients. This analysis used the two-dimensional finite element method, which incorporated boundary friction layers on both the inner and outer bearings of the prosthesis. Acetabular reaming increased stress within the pelvic bone and migration of the outer head. A combination of the acetabular reaming and bone transplantation increased the stress within the pelvic bone and grafted bone, and caused outer head migration. These findings were supported by clinical results. Although the bipolar endoprosthesis was biomechanically superior to the unipolar endoprosthesis, migration of the outer head still occurred. The bipolar endoprosthesis appeared to be indicated in cases of a femoral neck fracture or of avascular necrosis in the femoral head, but its use in cases of osteoarthritis in the hip required caution.

  15. Outcomes of nonoperatively treated displaced scapular body fractures.

    PubMed

    Dimitroulias, Apostolos; Molinero, Kenneth G; Krenk, Daniel E; Muffly, Matthew T; Altman, Daniel T; Altman, Gregory T

    2011-05-01

    Displaced scapular body fractures most commonly are treated conservatively. However there is conflicting evidence in the literature regarding the outcomes owing to retrospective design of studies, different classification systems, and diverse outcome tools. The functional outcome after nonoperative management of displaced scapular body fractures was assessed by change in the DASH (Disability of Arm, Shoulder and Hand) score; (2) the radiographic outcome was assessed by the change of the glenopolar angle (GPA); and (3) associated scapular and extrascapular injuries that may affect outcome were identified. Forty-nine consecutive patients were treated with early passive and active ROM exercises for a displaced scapular body fracture. We followed 32 of these patients (65.3%) for a minimum of 6 months (mean, 15 months; range, 6-33 months). Mean age of the patients was 46.9 years (range, 21-84 years) and the mean Injury Severity Score (ISS) was 21.5 (range, 5-50). Subjective functional results (DASH score) and radiographic assessment (fracture union, glenopolar angle) were measured. All fractures healed uneventfully. The mean change of glenopolar angle was 9° (range, 0°-20°). The mean change of the DASH score was 10.2, which is a change with minimal clinical importance. There was a correlation between the change in this score with the ISS and presence of rib fractures. Satisfactory outcomes are reported with nonoperative treatment of displaced scapular body fractures. We have shown that the severity of ISS and the presence of rib fractures adversely affect the clinical outcome.

  16. Effect of acetabular reinforcement ring with hook for acetabular dysplasia clarified by three-dimensional finite element analysis.

    PubMed

    Zhao, Xin; Chosa, Etsuo; Yamako, Go; Watanabe, Shinji; Deng, Gang; Totoribe, Koji

    2013-12-01

    The objective of this study was to biomechanically determine the effect of the severity of acetabular dysplasia, number and positions of screws and type of bone graft material used on the initial fixation strength of the acetabular reinforcement ring with hook (Ganz ring) using the finite element method. Relative micromotion increased as the severity of acetabular dysplasia increased and tended to decrease as the number of screws increased, but varied according to screw placement position. Increased strength of the bone graft material led to decreased relative micromotion. Biomechanically, the Ganz ring can be placed securely using 3 screws in patients with Crowe 1 dysplasia. However, in patients with Crowe 2 or higher dysplasia, it is necessary to spread at least 4 screws across an area of good host bone. © 2013.

  17. Functional outcomes after operatively treated patella fractures.

    PubMed

    LeBrun, Christopher T; Langford, Joshua R; Sagi, H Claude

    2012-07-01

    To evaluate the midterm functional outcomes of patients with isolated operatively treated patella fractures. Prospective cohort and retrospective clinical and radiographic assessment. A Level I and Level II trauma center. Two hundred forty-one patients underwent operative intervention for a displaced patella fracture between 1991 and 2007. After appropriate exclusions, 110 patients met criteria. A total of 40 (36%) patients with isolated, unilateral, operatively treated patella fractures with minimum 1-year follow-up agreed to participate in this study and return for functional testing. Mean follow-up was 6.5 years (range, 1.25-17 years). Enrolled patients were treated with one of the following methods: standard tension band with Kirschner wires, tension band through 2 cannulated screws, longitudinal anterior banding with cerclage, or partial patellectomy. All enrolled patients were evaluated with the SF-36 and an injury-specific questionnaire (Knee Injury and Osteoarthritis Outcome Scores) and asked to self-report symptomatic hardware. Patients were also evaluated by physical examination assessing range of motion and Biodex bilateral quadriceps isometric and isokinetic comparisons. The mean normalized SF-36 physical composite score and the mean normalized Knee Injury and Osteoarthritis Outcome Scores subscale scores (pain, 71.7; symptoms, 66.3; activities of daily living, 75.1; sport/recreation, 45.2; quality of life, 49.6) were statistically different (P < 0.05) from reference population norms. Removal of symptomatic fixation was required in 52% of the patients treated with osteosynthesis, whereas 38% of those with retained fixation self-reported implant-related pain at least some of the time. Eight patients (20%) had an extensor lag greater than 5°. A restricted range of flexion of greater than 5° was noted in 15 patients (38%) and restricted range of extension of greater than 5° was noted in 6 patients (15%). Biodex dynamometric testing revealed a mean

  18. Variation Among Pediatric Orthopaedic Surgeons When Treating Medial Epicondyle Fractures.

    PubMed

    Hughes, Meghan; Dua, Karan; O'Hara, Nathan N; Brighton, Brian K; Ganley, Theodore J; Hennrikus, William L; Herman, Martin J; Hyman, Joshua E; Lawrence, J Todd; Mehlman, Charles T; Noonan, Kenneth J; Otsuka, Norman Y; Schwend, Richard M; Shrader, M Wade; Smith, Brian G; Sponseller, Paul D; Abzug, Joshua M

    2017-10-18

    Medial epicondyle fractures are a common pediatric and adolescent injury accounting for 11% to 20% of elbow fractures in this population. This purpose of this study was to determine the variability among pediatric orthopaedic surgeons when treating pediatric medial epicondyle fractures. A discrete choice experiment was conducted to determine which patient and injury attributes influence the management of medial epicondyle fractures by pediatric orthopaedic surgeons. A convenience sample of 13 pediatric orthopaedic surgeons reviewed 60 case vignettes of medial epicondyle fractures that included elbow radiographs and patient/injury characteristics. Displacement was incorporated into the study model as a fixed effect. Surgeons were queried if they would treat the injury with immobilization alone or open reduction and internal fixation (ORIF). Statistical analysis was performed using a mixed effect regression model. In addition, surgeons filled out a demographic questionnaire and a risk assessment to determine if these factors affected clinical decision-making. Elbow dislocation and fracture displacement were the only attributes that significantly influenced surgeons to perform surgery (P<0.05). The presence of an elbow dislocation had the largest impact on surgeons when choosing operative care (β=-0.14; P=0.02). In addition, for every 1 mm increase in displacement, surgeons tended to favor ORIF by a factor of 0.09 (P<0.01). Sex, mechanism of injury, and sport participation did not influence decision-making. In total, 54% of the surgeons demonstrated a preference for ORIF for the included scenarios. On the basis of the personality Likert scale, participants were neither high-risk takers nor extremely risk adverse with an average-risk score of 2.24. Participant demographics did not influence decision-making. There is substantial variation among pediatric orthopaedic surgeons when treating medial epicondyle fractures. The decision to operate is significantly based on

  19. Reconstruction of failed acetabular component in the presence of severe acetabular bone loss: a systematic review.

    PubMed

    Volpin, A; Konan, S; Biz, C; Tansey, R J; Haddad, F S

    2018-04-13

    Acetabular revision especially in the presence of severe bone loss is challenging. There is a paucity of literature critiquing contemporary techniques of revision acetabular reconstruction and their outcomes. The purpose of this study was to systematically review the literature and to report clinical outcomes and survival of contemporary acetabular revision arthroplasty techniques (tantalum metal shells, uncemented revision jumbo shells, reinforced cages and rings, oblong shells and custom-made triflange constructs). Full-text papers and those with an abstract in English published from January 2001 to January 2016 were identified through international databases. A total of 50 papers of level IV scientific evidence, comprising 2811 hips in total, fulfilled the inclusion criteria and were included. Overall, patients had improved outcomes irrespective of the technique of reconstruction as documented by postoperative hip scores. Our pooled analysis suggests that oblong cups components had a lower failure rate compared with other different materials considered in this review. Custom-made triflange cups had one of highest failure rates. However, this may reflect the complexity of revisions and severity of bone loss. The most common postoperative complication reported in all groups was dislocation. This review confirms successful acetabular reconstructions using diverse techniques depending on the type of bone loss and highlights key features and outcomes of different techniques. In particular, oblong cups and tantalum shells have successful survivorship.

  20. Acetabular-epiphyseal angle and hip dislocation in cerebral palsy: a preliminary study.

    PubMed

    Alí-Morell, O J; Zurita-Ortega, F; Davó-Jiménez, I; Segura-Biedma, S

    To relate, in non-ambulatory subjects with palsy, Reimers' migration percentage with standardized radiological measurements, including the acetabular-epiphyseal angle. Descriptive, observational and transversal study of 15 individuals with cerebral palsy at levels IV and V of the Gross Motor Function Classification System, aged between 3 and 9 years. Radiological measurements of the acetabular index, Hilgenreiner's epiphyseal angle, acetabular-epiphyseal angle, neck-shaft angle and Reimers' migration percentage of each of the hips were performed. Correlations between acetabular index, epiphyseal angle and acetabular-epiphyseal angle were obtained with respect to the Reimers migration percentage. For hips with a migration rate of 15% or less, a positive correlation was observed between acetabular and epiphyseal angles. In our population, the measurement between acetabular and epiphyseal inclination represents the highest association with the hip migration percentage. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Polyethylene wear debris in modular acetabular prostheses.

    PubMed

    Chen, P C; Mead, E H; Pinto, J G; Colwell, C W

    1995-08-01

    The longevity of total hip arthroplasty has brought forth the recognition of aseptic loosening of prosthetic components as the leading cause of implant failure. Modularity of implants, although a significant improvement in versatility, may increase debris formation, a recognized cause of implant failure. This study was designed to measure the relative motion, and to assess the polyethylene wear debris production at the interface between the metal acetabular shell and the back side of the polyethylene liner, in modular hip prostheses. Five models from 4 manufacturers with different locking mechanisms and acetabular shell surface treatments were tested under long-term simultaneous sinusoidal and static loading (10(7) cycles at 3 Hz with +/- 2.5 Nmeter and 220 N static load). Results showed that there were marked differences in the security of the acetabular shell and polyethylene liner locking mechanism, wear pattern, damage sites, and amount of polyethylene debris on the acetabular shell and polyethylene liner surfaces. The range of polyethylene liner motion observed among the 5 models during 1 cycle of testing varied from an average of 0.96 degrees to movement too small to be detected by the test machines. Image and scanning electron microscopy analysis showed different wear patterns and a wide range in the average polyethylene liner surface wear area (0.26 cm2-4.61 cm2). In general, a stable locking mechanism and a smooth acetabular shell surface are essential in minimizing polyethylene liner wear and polyethylene debris production.

  2. [Quantification of acetabular coverage in normal adult].

    PubMed

    Lin, R M; Yang, C Y; Yu, C Y; Yang, C R; Chang, G L; Chou, Y L

    1991-03-01

    Quantification of acetabular coverage is important and can be expressed by superimposition of cartilage tracings on the maximum cross-sectional area of the femoral head. A practical Autolisp program on PC AutoCAD has been developed by us to quantify the acetabular coverage through numerical expression of the images of computed tomography. Thirty adults (60 hips) with normal center-edge angle and acetabular index in plain X ray were randomly selected for serial drops. These slices were prepared with a fixed coordination and in continuous sections of 5 mm in thickness. The contours of the cartilage of each section were digitized into a PC computer and processed by AutoCAD programs to quantify and characterize the acetabular coverage of normal and dysplastic adult hips. We found that a total coverage ratio of greater than 80%, an anterior coverage ratio of greater than 75% and a posterior coverage ratio of greater than 80% can be categorized in a normal group. Polar edge distance is a good indicator for the evaluation of preoperative and postoperative coverage conditions. For standardization and evaluation of acetabular coverage, the most suitable parameters are the total coverage ratio, anterior coverage ratio, posterior coverage ratio and polar edge distance. However, medial coverage and lateral coverage ratios are indispensable in cases of dysplastic hip because variations between them are so great that acetabuloplasty may be impossible. This program can also be used to classify precisely the type of dysplastic hip.

  3. Fracture of Ceramic Liner and Head in a Total Hip Arthroplasty with a Sandwich Type Cup

    PubMed Central

    Reátegui, Diego; García, Sebastián; Bori, Guillem; Gallart, Xavier

    2013-01-01

    Due to its advantages, ceramic-on-ceramic bearings have been widely used in young patients for almost 30 years. Long-term survivorship, low wear, and low biological reactivity to particles are some of its characteristics. Even though this material has had a lot of improvements, the risk of fracture is one of the concerns. There have been reports of fracture of ceramic in the acetabular liner and head but no fractures of both in the same patient. We report a case of a fracture in a sandwich type acetabular liner and the ceramic head in a patient involving ankylosing spondylitis. It occurred three years after the operation and with no history of direct trauma. We decided to change the bearing surfaces to metal polyethylene without removing the metal back. The patient is satisfied by the clinical results after a 5-year followup. PMID:23691392

  4. Can we assess healing of surgically treated long bone fractures on radiograph?

    PubMed

    Perlepe, V; Omoumi, P; Larbi, A; Putineanu, D; Dubuc, J-E; Schubert, T; Vande Berg, B

    2018-06-01

    To determine the frequency and causes for limitations in the radiographic evaluation of surgically treated long bone fractures. Six readers separately scored 140 sets of antero-posterior (AP) and lateral radiographs of surgically treated long bone fractures, using a radiographic union score (RUS). We determined the rate of assessability of the fracture edges at each of the four cortical segments (n=560) seen tangentially on the two radiographs and the causes for non-assessability. The rate of feasibility of the RUS (more than two fracture edges assessable per fracture) was determined and compared according to different parameters. Fracture edges were visible in 71% to 81% of the 560 cortical segments. Metal hardware superimposition was the most frequent cause for non-assessability (79-95%). RUS values could be calculated in 58% to 75% of fractures. Scoring was statistically significantly less frequently calculable in plated (31-56%) than in nailed fractures (90-97%), in distal (47-61%) than in proximal (78-89%) bones and in upper (27-49%) than in lower (76-91%) limb bones (P≤0.01). The type of stabilization hardware is the main limiting factor in the radiographic assessment of surgically treated long bone fractures. Scoring was feasible in only 31% to 56% of plated fractures. Copyright © 2018 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  5. Evaluation of the three-dimensional bony coverage before and after rotational acetabular osteotomy.

    PubMed

    Tanaka, Takeyuki; Moro, Toru; Takatori, Yoshio; Oshima, Hirofumi; Ito, Hideya; Sugita, Naohiko; Mitsuishi, Mamoru; Tanaka, Sakae

    2018-02-26

    Rotational acetabular osteotomy is a type of pelvic osteotomy that involves rotation of the acetabular bone to improve the bony coverage of the femoral head for patients with acetabular dysplasia. Favourable post-operative long-term outcomes have been reported in previous studies. However, there is a paucity of published data regarding three-dimensional bony coverage. The present study investigated the three-dimensional bony coverage of the acetabulum covering the femoral head in hips before and after rotational acetabular osteotomy and in normal hips. The computed tomography data of 40 hip joints (12 joints before and after rotational acetabular osteotomy; 16 normal joints) were analyzed. The three-dimensional bony coverage of each joint was evaluated using original software. The post-operative bony coverage improved significantly compared with pre-operative values. In particular, the anterolateral aspect of the acetabulum tended to be dysplastic in patients with acetabular dysplasia compared to those with normal hip joints. However, greater bony coverage at the anterolateral aspect was obtained after rotational acetabular osteotomy. Meanwhile, the results of the present study may indicate that the bony coverage in the anterior aspect may be excessive. Three-dimensional analysis indicated that rotational acetabular osteotomy achieved favorable bony coverage. Further investigations are necessary to determine the ideal bony coverage after rotational acetabular osteotomy.

  6. Acetabular inclination and anteversion in infants using 3D MR imaging.

    PubMed

    Falliner, A; Muhle, C; Brossmann, J

    2002-03-01

    To establish if 3D MR imaging could be used for measurements of acetabular inclination and anteversion in infants specimens. 3D MR data of 3 pelvic preparations of 6-week- to 10-month-old infant specimens was gathered. MR imaging in transaxial and frontal planes was carried out to measure the acetabular inclination and anteversion: a method to determine the MR planes for measurements is described. It was oriented on anatomical landmarks of the pelvis and therefore allowed adjustment of the frontal and transaxial planes, independent of the pelvis position. The mean acetabular inclination angle was 48 degrees, and the mean acetabular anteversion was 23 degrees. Because of the low number of cases the results can only be assessed as a tendency, but MR imaging seems to be suitable for measurements of acetabular inclination and anteversion.

  7. A novel method to assess primary stability of press-fit acetabular cups.

    PubMed

    Crosnier, Emilie A; Keogh, Patrick S; Miles, Anthony W

    2014-11-01

    Initial stability is an essential prerequisite to achieve osseointegration of press-fit acetabular cups in total hip replacements. Most in vitro methods that assess cup stability do not reproduce physiological loading conditions and use simplified acetabular models with a spherical cavity. The aim of this study was to investigate the effect of bone density and acetabular geometry on cup stability using a novel method for measuring acetabular cup micromotion. A press-fit cup was inserted into Sawbones(®) foam blocks having different densities to simulate normal and osteoporotic bone variations and different acetabular geometries. The stability of the cup was assessed in two ways: (a) measurement of micromotion of the cup in 6 degrees of freedom under physiological loading and (b) uniaxial push-out tests. The results indicate that changes in bone substrate density and acetabular geometry affect the stability of press-fit acetabular cups. They also suggest that cups implanted into weaker, for example, osteoporotic, bone are subjected to higher levels of micromotion and are therefore more prone to loosening. The decrease in stability of the cup in the physiological model suggests that using simplified spherical cavities to model the acetabulum over-estimates the initial stability of press-fit cups. This novel testing method should provide the basis for a more representative protocol for future pre-clinical evaluation of new acetabular cup designs. © IMechE 2014.

  8. Press-fit versus threaded acetabular cups in total hip arthroplasty: Functional and radiological results after five years.

    PubMed

    Ellenrieder, Martin; Bader, Rainer; Bergschmidt, Philipp; Mittelmeier, Wolfram

    2016-03-01

    Prospectively the outcome after total hip replacement with a new threaded acetabular cup design was compared to an established press-fit cup. After 1, 2 and 5 years, the 36-item Short Form Health Survey, Western Ontario and McMaster University Osteoarthritis Index and Harris Hip Score revealed no significant differences between the two groups (each group: n=42 patients), except for a higher Harris Hip Score in the threaded cup group after five years (p=0.02). After five years, one threaded cup had a mild radiolucent line without further signs of loosening. All other cups of both groups (98.6%) showed a full osseous integration. The cup inclination angle ranged from 41-58° (threaded cups) to 39-77° (press-fit cups). The new threaded cup provides equivalent clinical outcomes and osseous integration but more precise implant positioning compared to the press-fit design. No complications typically ascribed to threaded cups (acetabular fractures, bone resorption, nerve impairment) occurred.

  9. [Should one choose the nail or the plate in treating a leg fracture?].

    PubMed

    Vives, P; Massy, E; Dubois, P; Decoopmann, P

    1975-12-01

    The authors have analysed the results of 126 tibial fractures treated by blind nailing with reaming and 112 tibial fractures treated by plating. They noted 5 septic complications after nailing, after plating, one non-union after nailing and 12 after plating, 3 malunions after nailing and 2 after plating. The cases treated by nailing united earlier. The Authors conclude that nailing is a more fiable technique than plating, and that the only fractures which should be plated are those which are not fit for nailing.

  10. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip) acetabular...

  11. Investigation of Mechanical Properties and Fracture Simulation of Solution-Treated AA 5754

    NASA Astrophysics Data System (ADS)

    Kumar, Pankaj; Singh, Akhilendra

    2017-10-01

    In this work, mechanical properties and fracture toughness of as-received and solution-treated aluminum alloy 5754 (AA 5754) are experimentally evaluated. Solution heat treatment of the alloy is performed at 530 °C for 2 h, and then, quenching is done in water. Yield strength, ultimate tensile strength, impact toughness, hardness, fatigue life, brittle fracture toughness (K_{Ic} ) and ductile fracture toughness (J_{Ic} ) are evaluated for as-received and solution-treated alloy. Extended finite element method has been used for the simulation of tensile and fracture behavior of material. Heaviside function and asymptotic crack tip enrichment functions are used for modelling of the crack in the geometry. Ramberg-Osgood material model coupled with fracture energy is used to simulate the crack propagation. Fracture surfaces obtained from various mechanical tests are characterized by scanning electron microscopy.

  12. Acetabular labral tears in patients with sports injury.

    PubMed

    Kang, Chan; Hwang, Deuk-Soo; Cha, Soo-Min

    2009-12-01

    We wanted to investigate acetabular labral tears and their correlation with femoroacetabular impingement in patients with sports injury. Among 111 patients who were diagnosed with the acetabular labral tears after arthroscopic treatment from January 2004 to December 2007, we selected 41 patients with sports injury. There were 12 cases of Taekwondo injury, 5 of golf injury, 4 of soccer injury, 3 of gymnastics injury, 2 of Hapkido injury, 2 of aerobics injury, 2 of rock-climbing injury, 2 of fitness training injury and 9 of other sports injuries. We checked the subtypes of acetabular labral tears and the accompanying femoroacetabular impingement. For the cases with accompanying femoroacetabular impingement, we investigated the subtypes according to the types of sports, gender and age. At last follow-up, we checked the Harris Hip Score (HHS), the Hip Outcome Score (HOS) sports scale and the percentage of patients who returned to their sports activity. The average age of symptomatic onset was 26 years (range, 12 to 65 years). The ratio of males to females was 29 : 12. An average duration of the hip pain was 17 months (range, 1 to 60 months). The degenerative type of acetabular labral tears was the most prevalent with 32 cases (78%), and there were 9 cases (22%) of the partial tear type. Thirty cases (73%) were accompanied by femoroacetabular impingement. The average age of the 23 cases (56%) of the cam-type was 23 years (range, 12 to 48 years), and it was more likely to occur in men (87%) and for people practicing martial arts such as Taekwondo or Hapkido. An average age of the 5 cases (12%) of the pincer-type was 26 (range, 16 to 43 years), it usually occurred in women (60%) and for non-martial arts such as golf and gymnastics. There were 2 cases of the mixed type (cam + pincer-type). At 27 months follow-up, the HHS was 61 to 92 points, the HOS sports scale increased 43 to 75%, and the rate of returning to sports was 71%. In spite of the early expression of symptoms

  13. Long-term results with the Atlas IIIp elastic cementless acetabular component in total hip replacement.

    PubMed

    Lee, Paul Yuh Feng; Rachala, Madhu; Teoh, Kar Ho; Woodnutt, David John

    2016-09-01

    Modular cementless elastic acetabular systems have advantages over cemented and hard shell cementless acetabular systems. There are few reports on the medium-term and long-term follow up of this particular type of implant. This study describes our experience with the Atlas IIIp modular acetabular system, which is a thin shell cementless elastic acetabular implant for total hip replacement commercialized under this name in many countries. We prospectively followed 244 patients treated with Atlas IIIp acetabular system between 2001 and 2004. Minimum ten year follow up was available for 148 hips (139 patients) from the original cohort of 263 hips (244 patients). One hundred five patients had died from unrelated causes and were excluded from the results. Post-operative and follow up radiographs of patients were assessed; and Harris hip scores were used as clinical outcome. Revision for any reason was defined as the end point for survivorship analysis. The mean pre-operative Harris hip score was 48 (S.D. 16) and the average post-operative score was 82 (S.D. 12). The mean follow up in our series was 11.5 years, ranging from ten to 13.5 years. Thirteen hips required further surgery in our cohort; of which ten cases required cup revision. The 13-years cumulative implant survival was 91.2 % and the risk of implant revision was 8.8 % at 13 years in 148 hips (139 patients). Kaplan-Meier analysis showed the implant survival rate of 95.2 % at ten years for revision for any reason and 99.4 % for aseptic loosening. Our clinical experience with this acetabular cup suggests good long-term survival rates that are similar to other cups on the market. The clinical experience in this study shows long-term survival rates that are consistent, acceptable and good results achieved with a low revision rate. Therapeutic III; therapeutic study.

  14. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint (hemi-hip) acetabular metal cemented... (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip) acetabular metal cemented prosthesis is a device intended to be implanted to replace a portion of the hip joint...

  15. Basic considerations for determining the amount of press fit in acetabular cup endoprostheses as a function of the elastic bone behavior.

    PubMed

    Winter, Werner; Karl, Matthias

    2014-10-01

    Acetabular cup endoprostheses are frequently placed in pelvic bone, employing the mechanical principle of press fit. While a sufficiently stable bone-implant connection is desirable, deformation of the cup and fracture of the pelvis should be avoided. The goal of this work is to demonstrate the importance of the elastic properties of bone on the amount of press fit achievable in a specific situation. On the basis of previous work describing the relation between relative bone mineral density and relative elastic modulus for cortical and trabecular bone, mechanical equations were used for analyzing the press-fit loading situation of an acetabular cup. Additionally, a two-dimensional finite element model was used for visualizing the stress and strain situation in the host bone occurring as a consequence of implant insertion, as well as the effect of moment loads acting on the acetabular cup. Given the fact that oversizing the implant for a specific recipient site is the only clinical means of optimizing press fit, knowledge of the elastic properties of the host bone before implant selection would be beneficial. Such information could, for instance, be derived from intraoperative compressive testing of the host bone.

  16. Treating patella fractures with a fixed-angle patella plate-A prospective observational study.

    PubMed

    Wild, Michael; Fischer, Kai; Hilsenbeck, Florian; Hakimi, Mohssen; Betsch, Marcel

    2016-08-01

    Anterior tension wiring using Kirschner wires (K-wires) is still considered the standard treatment for patella fractures, despite its high complication rate. The objective of this prospective clinical study was to evaluate intra- and perioperative complications as well as the clinical outcome of patients with patella fracture treated with a new developed bilateral, polyaxial, fixed-angle 2.7mm patella plate. Between 2011 and 2014 all patients with a patella fracture were included in this prospective study and treated with a fixed-angle patella plate. Avulsion fractures of the inferior or superior pole of the patella were excluded. All fractures were classified according to the AO/OTA fracture classification. During a twelve-month follow up period all intra- and postoperative complications were recorded as well as the time until fracture healing. One year postoperatively the Lysholm Score, the pre- and postoperative Tegner Score, the Hospital for Special Surgery Knee Score (HSS), the Turba Score, the Oxford Knee Score, the Knee injury and Osteoarthritis Outcome Score (KOOS), the Bostman Score and the Iowa Knee Score were surveyed. Altogether, 20 patella fractures in 19 patients were included in this prospective study. The most frequent type of fracture, n=10, was a simple transverse patella fracture (C1), followed by 7 comminuted patella fractures (C3) and 3 T-shaped patella fractures (C2). During the 12-month follow up period two patients treated with the patella plate had a complication. In one patient a superficial wound infection occurred, which was treated successfully with hardware removal and in one patient a fracture dislocation due to an implant failure occurred. X-rays demonstrated complete bony healing in all fractures on average 3.2 months postoperatively. All knee scores showed good to excellent clinical results one year postoperatively. The results of this first clinical study indicate that the fixed-angle patella plate is an effective and safe

  17. Interventions for treating fractures of the patella in adults.

    PubMed

    Sayum Filho, Jorge; Lenza, Mário; Teixeira de Carvalho, Rogerio; Pires, Osvaldo G N; Cohen, Moisés; Belloti, João Carlos

    2015-02-27

    Fractures of the patella (kneecap) account for around 1% of all human fractures. The treatment of these fractures can be surgical or conservative (such as immobilisation with a cast or brace). There are many different surgical and conservative interventions for treating fractures of the patella in adults. To assess the effects (benefits and harms) of interventions (surgical and conservative) for treating fractures of the patella in adults. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register (2 May 2014), the Cochrane Central Register of Controlled Trials (The Cochrane Library, 2014, Issue 4), MEDLINE (1946 to April Week 4 2014), Ovid MEDLINE In-Process & Other Non-Indexed Citations (2 May 2014), Embase (1980 to 2014 Week 17), LILACS (1982 to 2 May 2014), trial registers and references lists of articles. Randomised controlled trials (RCTs) or quasi-RCTs that evaluated any surgical or conservative intervention for treating adults with fractures of the patella were eligible for inclusion. The primary outcomes were patient-rated knee function and knee pain, and major adverse outcomes. At least two review authors independently selected eligible trials, assessed risk of bias and cross-checked data extraction. Where appropriate, results of comparable trials were pooled. We included five small trials involving 169 participants with patella fractures. Participant age ranged from 16 to 76 years. There were 68 females and 100 males; the gender of one participant was not reported. Two trials were conducted in China and one each in Finland, Mexico and Turkey.All five trials compared different surgical interventions. Two trials compared biodegradable versus metallic implants for treating displaced patella fractures; one trial compared patellectomy with advancement of vastus medialis obliquus versus simple patellectomy for treating comminuted patella fractures; and two trials compared percutaneous osteosynthesis (both procedures were 'novel' and one

  18. Delay in weight bearing in surgically treated tibial shaft fractures is associated with impaired healing: a cohort analysis of 166 tibial fractures.

    PubMed

    Houben, I B; Raaben, M; Van Basten Batenburg, M; Blokhuis, T J

    2018-04-09

    The relation between timing of weight bearing after a fracture and the healing outcome is yet to be established, thereby limiting the implementation of a possibly beneficial effect for our patients. The current study was undertaken to determine the effect of timing of weight bearing after a surgically treated tibial shaft fracture. Surgically treated diaphyseal tibial fractures were retrospectively studied between 2007 and 2015. The timing of initial weight bearing (IWB) was analysed as a predictor for impaired healing in a multivariate regression. Totally, 166 diaphyseal tibial fractures were included, 86 cases with impaired healing and 80 with normal healing. The mean age was 38.7 years (range 16-89). The mean time until IWB was significantly shorter in the normal fracture healing group (2.6 vs 7.4 weeks, p < 0.001). Correlation analysis yielded four possible confounders: infection requiring surgical intervention, fracture type, fasciotomy and open fractures. Logistic regression identified IWB as an independent predictor for impaired healing with an odds ratio of 1.13 per week delay (95% CI 1.03-1.25). Delay in initial weight bearing is independently associated with impaired fracture healing in surgically treated tibial shaft fractures. Unlike other factors such as fracture type or soft tissue condition, early resumption of weight bearing can be influenced by the treating physician and this factor therefore has a direct clinical relevance. This study indicates that early resumption of weight bearing should be the treatment goal in fracture fixation. 3b.

  19. A Prolonged Time Interval Between Trauma and Prophylactic Radiation Therapy Significantly Increases the Risk of Heterotopic Ossification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mourad, Waleed F., E-mail: Waleed246@gmail.com; Department of Radiation Oncology, Beth Israel Medical Center, New York, NY; Packianathan, Satyaseelan

    2012-03-01

    Purpose: To ascertain whether the time from injury to prophylactic radiation therapy (RT) influences the rate of heterotopic ossification (HO) after operative treatment of displaced acetabular fractures. Methods and Materials: This is a single-institution, retrospective analysis of patients referred for RT for the prevention of HO. Between January 2000 and January 2009, 585 patients with displaced acetabular fractures were treated surgically followed by RT for HO prevention. We analyzed the effect of time from injury on prevention of HO by RT. In all patients, 700 cGy was prescribed in a single fraction and delivered within 72 hours postsurgery. The patientsmore » were stratified into five groups according to time interval (in days) from the date of their accident to the date of RT: Groups A {<=}3, B {<=}7, C {<=}14, D {<=}21, and E >21days. Results: Of the 585 patients with displaced acetabular fractures treated with RT, (18%) 106 patients developed HO within the irradiated field. The risk of HO after RT increased from 10% for RT delivered {<=}3 days to 92% for treatment delivered >21 days after the initial injury. Wilcoxon test showed a significant correlation between the risk of HO and the length of time from injury to RT (p < 0.0001). Chi-square test and multiple logistic regression analysis showed no significant association between all other factors and the risk of HO (race, gender, cause and type of fracture, surgical approach, or the use of indomethacin). Conclusions: Our data suggest that there is higher incidence and risk of HO if prophylactic RT is significantly delayed after a displaced acetabular fracture. Thus, RT should be administered as early as clinically possible after the trauma. Patients undergoing RT >3 weeks from their displaced acetabular fracture should be informed of the higher risk (>90%) of developing HO despite prophylaxis.« less

  20. [APPLICATION AND EFFECTIVENESS OF BIOLOGICAL TYPE ACETABULAR CUP IN ADULT Crowe TYPE IV DEVELOPMENTAL DYSPLASIA OF THE HIP].

    PubMed

    Xu, Ning; Sun, Junying; Zhao, Xijiang; Wang, Tao

    2016-01-01

    To investigate the application and effectiveness of the biological type acetabular cup(diameter < 44 mm) in adult Crowe type IV developmental dysplasia of the hip (DDH). Between April 2001 andAugust 2013, biological type acetabular cup was used in total hip arthroplasty for the treatment of Crowe type IV DDH in16 cases (20 hips). There were 3 males and 13 females, aged 31-69 years (mean, 49 years). Unilateral hip was involved in 12cases, and bilateral hips in 4 cases. The patients showed pain of the hip joint and inequality of lower limb (shortening ofaffected limb 1.8-6.0 cm in length, 3.5 cm on average). Acetabular deformity, the relationship and the severity of femoralhead dislocation were comfirmed on the X-ray films. The preoperative Harris score was 34.0 ± 6.9. All patientsachieved healing of incision by first intention, with no complication of infection or neurovascular injury. Sixteen caseswere followed up 4-12 years (mean, 7.5 years). At 2 weeks after operation, dislocation occurred in 2 cases, and were fixedwith plaster for 3 weeks after reduction of the hip. Postoperative X-ray films showed complete reduction of femoral head;the average acetabular coverage of the cup of the weight-bearing area was 98.5% (range, 98.2%-99.1%). The cup from theRanawat triangle was 4.6-7.0 mm (mean, 5.8 mm) in medial shifting, and was 4.5-7.9 mm (mean, 6.2 mm) in elevation,it located at cup lateral surface area inside the iliopectineal line and the Kohler line (< 40%); the cup abduction angle was(45 ± 5)degrees, and the anteversion angle was (10 ± 5)degrees. The other patients had no prosthesis loosening except 1 patient havingextensive acetabular prosthesis loosening because of acetabular osteolysis at 12 years after operation. The hip Harris scorewas significantly improved to 85.0 ± 7.5 at 1 year after operation (t = 14.34, P = 0.01). The acetabular grindingprocess to retain enough bone combined with a small cup of-biological prosthesis treating adult Crowe type IV DDH

  1. Ca 45 Uptake in Fracture Callus of Normal and Aminoacetonitrile-Treated Rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bolognani, L.; Ponseti, T. V.

    1962-04-01

    Calcium content and Ca 45 uptake were measured in the fracture callus of normal and AAN-treated rats. It appears that total calcium deposition and Ca 45 uptake are both higher in the young callus, 5 and 10 days after fracture, of the AAN-treated animals. By the 20th day, mineralization of the callus in both groups is similar.

  2. Enhanced chondrogenesis and Wnt signaling in PTH-treated fractures.

    PubMed

    Kakar, Sanjeev; Einhorn, Thomas A; Vora, Siddharth; Miara, Lincoln J; Hon, Gregory; Wigner, Nathan A; Toben, Daniel; Jacobsen, Kimberly A; Al-Sebaei, Maisa O; Song, Michael; Trackman, Philip C; Morgan, Elise F; Gerstenfeld, Louis C; Barnes, George L

    2007-12-01

    Studies have shown that systemic PTH treatment enhanced the rate of bone repair in rodent models. However, the mechanisms through which PTH affects bone repair have not been elucidated. In these studies we show that PTH primarily enhanced the earliest stages of endochondral bone repair by increasing chondrocyte recruitment and rate of differentiation. In coordination with these cellular events, we observed an increased level of canonical Wnt-signaling in PTH-treated bones at multiple time-points across the time-course of fracture repair, supporting the conclusion that PTH responses are at least in part mediated through Wnt signaling. Since FDA approval of PTH [PTH(1-34); Forteo] as a treatment for osteoporosis, there has been interest in its use in other musculoskeletal conditions. Fracture repair is one area in which PTH may have a significant clinical impact. Multiple animal studies have shown that systemic PTH treatment of healing fractures increased both callus volume and return of mechanical competence in models of fracture healing. Whereas the potential for PTH has been established, the mechanism(s) by which PTH produces these effects remain elusive. Closed femoral fractures were generated in 8-wk-old male C57Bl/6 mice followed by daily systemic injections of either saline (control) or 30 microg/kg PTH(1-34) for 14 days after fracture. Bones were harvested at days 2, 3, 5, 7, 10, 14, 21, and 28 after fracture and analyzed at the tissue level by radiography and histomorphometry and at the molecular and biochemical levels level by RNase protection assay (RPA), real-time PCR, and Western blot analysis. Quantitative muCT analysis showed that PTH treatment induced a larger callus cross-sectional area, length, and total volume compared with controls. Molecular analysis of the expression of extracellular matrix genes associated with chondrogenesis and osteogenesis showed that PTH treated fractures displayed a 3-fold greater increase in chondrogenesis relative to

  3. Secure corridor for infraacetabular screws in acetabular fracture fixation-a 3-D radiomorphometric analysis of 124 pelvic CT datasets.

    PubMed

    Arlt, Stephan; Noser, Hansrudi; Wienke, Andreas; Radetzki, Florian; Hofmann, Gunther Olaf; Mendel, Thomas

    2018-05-21

    Acetabular fracture surgery is directed toward anatomical reduction and stable fixation to allow for the early functional rehabilitation of an injured hip joint. Recent biomechanical investigations have shown the superiority of using an additional screw in the infraacetabular (IA) region, thereby transfixing the separated columns to strengthen the construct by closing the periacetabular fixation frame. However, the inter-individual existence and variance concerning secure IA screw corridors are poorly understood. This computer-aided 3-D radiomorphometric study examined 124 CT Digital Imaging and Communications in Medicine (DICOM) datasets of intact human pelves (248 acetabula) to visualize the spatial IA corridors as the sum of all intraosseous screw positions. DICOM files were pre-processed using the Amira® 4.2 visualization software. Final corridor computation was accomplished using a custom-made software algorithm. The volumetric measurement data of each corridor were calculated for further statistical analyses. Correlations between the volumetric values and the biometric data were investigated. Furthermore, the influence of hip dysplasia on the IA corridor configuration was analyzed. The IA corridors consistently showed a double-cone shape with the isthmus located at the acetabular fovea. In 97% of male and 91% of female acetabula, a corridor for a 3.5-mm screw could be found. The number of IA corridors was significantly lower in females for screw diameters ≥ 4.5 mm. The mean 3.5-mm screw corridor volume was 16 cm 3 in males and 9.2 cm 3 in female pelves. Corridor volumes were significantly positively correlated with body height and weight and with the diameter of Köhler's teardrop on standard AP pelvic X-rays. No correlation was observed between hip dysplasia and the IA corridor extent. IA corridors are consistently smaller in females. However, 3.5-mm small fragment screws may still be used as the standard implant because sex-specific differences are

  4. Rate of displacement for Jakob Type 1 lateral condyle fractures treated with a cast.

    PubMed

    Zale, C; Winthrop, Z A; Hennrikus, W

    2018-04-01

    The aim of this retrospective study is to report the rate of displacement of Jakob Type 1 lateral condyle fractures that were initially treated in a cast. We performed a retrospective review of all patients that were treated for a non-displaced (Jakob Type 1 < 2 mm) lateral condyle fracture of the humerus at our institution between 2002 and 2015. A total of 59 patients were initially treated with casting. Five fractures displaced and were converted to a closed pinning treatment plan with a conversion rate of 8.5%. There was a mean of 13.2 days (4 to 21) between treatment by initial casting and closed pinning. This study demonstrates an 8.5% displacement and conversion rate from cast treatment to closed pinning for initially non-displaced Jakob Type 1 lateral condyle fractures of the humerus. The internal oblique radiograph is most accurate to determine displacement. We recommend obtaining an internal oblique view at initial evaluation and at follow-up in the cast for lateral condyle fractures. To minimize movement at the fracture site, we recommend treating Jakob Type 1 lateral condyle fractures with a long arm cast with the elbow at 90° and the forearm in the supine position with a sling-loop design. IV - retrospective therapeutic study.

  5. Comparison of Short vs Long Anti-rotation in Treating Trochanteric Fractures.

    PubMed

    Raval, P; Ramasamy, A; Raza, H; Khan, K; Awan, N

    2016-03-01

    Introduction : A comparative evaluation of the surgical treatment and outcome of patients with pertrochanteric fractures treated with short versus long proximal femoral nail antirotation. Materials and methods : A retrospective review was conducted of patients with pertrochanteric fractures treated between January 2011 and June 2012. In all 80 patients were enrolled in the study, of which 40 were treated with short PFNA and the remaining with long PFNA. Comparative analyses of demographic data, peri-operative outcome and complications were carried out. Results : There was no significant difference noted in the two groups with regards to Arbeitsgemeinschaft fur Osteosynthesefragen (AO) fracture classification, time from injury to surgery, blood transfusion post surgery and hospital stay. The surgical duration for a short PFNA procedure was significantly less (58 minutes) when compared to that of a long PFNA (87 minutes). Similarly intra-operative blood loss was significantly higher in the long PFNA group as compared to the short PFNA. Conclusions : A relatively quicker surgical time of just under an hour , lesser blood loss and better learning curve with trainee surgeons make short PFNA a better implant choice in the treatment of pertrochanteric fractures.

  6. Single-stage Acetabular Revision During Two-stage THA Revision for Infection is Effective in Selected Patients.

    PubMed

    Fink, Bernd; Schlumberger, Michael; Oremek, Damian

    2017-08-01

    The treatment of periprosthetic infections of hip arthroplasties typically involves use of either a single- or two-stage (with implantation of a temporary spacer) revision surgery. In patients with severe acetabular bone deficiencies, either already present or after component removal, spacers cannot be safely implanted. In such hips where it is impossible to use spacers and yet a two-stage revision of the prosthetic stem is recommended, we have combined a two-stage revision of the stem with a single revision of the cup. To our knowledge, this approach has not been reported before. (1) What proportion of patients treated with single-stage acetabular reconstruction as part of a two-stage revision for an infected THA remain free from infection at 2 or more years? (2) What are the Harris hip scores after the first stage and at 2 years or more after the definitive reimplantation? Between June 2009 and June 2014, we treated all patients undergoing surgical treatment for an infected THA using a single-stage acetabular revision as part of a two-stage THA exchange if the acetabular defect classification was Paprosky Types 2B, 2C, 3A, 3B, or pelvic discontinuity and a two-stage procedure was preferred for the femur. The procedure included removal of all components, joint débridement, definitive acetabular reconstruction (with a cage to bridge the defect, and a cemented socket), and a temporary cemented femoral component at the first stage; the second stage consisted of repeat joint and femoral débridement and exchange of the femoral component to a cementless device. During the period noted, 35 patients met those definitions and were treated with this approach. No patients were lost to followup before 2 years; mean followup was 42 months (range, 24-84 months). The clinical evaluation was performed with the Harris hip scores and resolution of infection was assessed by the absence of clinical signs of infection and a C-reactive protein level less than 10 mg/L. All

  7. Validation of a new radiographic measurement of acetabular version: the transverse axis distance (TAD).

    PubMed

    Nitschke, Ashley; Lambert, Jeffery R; Glueck, Deborah H; Jesse, Mary Kristen; Mei-Dan, Omer; Strickland, Colin; Petersen, Brian

    2015-11-01

    This study has three aims: (1) validate a new radiographic measure of acetabular version, the transverse axis distance (TAD) by showing equivalent TAD accuracy in predicting CT equatorial acetabular version when compared to a previously validated, but more cumbersome, radiographic measure, the p/a ratio; (2) establish predictive equations of CT acetabular version from TAD; (3) calculate a sensitive and specific cut point for predicting excessive CT acetabular anteversion using TAD. A 14-month retrospective review was performed of patients who had undergone a dedicated MSK CT pelvis study and who also had a technically adequate AP pelvis radiograph. Two trained observers measured the radiographic p/a ratio, TAD, and CT acetabular equatorial version for 110 hips on a PACS workstation. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of p/a ratio and TAD. CT equatorial acetabular version can accurately be predicted from either p/a ratio (p < 0.001) or TAD (p < 0.001). The diagnostic accuracies of p/a ratio and TAD are comparable (p =0.46). Patients whose TAD is higher than 17 mm may have excessive acetabular anteversion. For that cutpoint, the sensitivity of TAD is 0.73, with specificity of 0.82. TAD is an accurate radiographic predictor of CT acetabular anteversion and provides an easy-to-use and intuitive point-of-care assessment of acetabular version in patients with hip pain.

  8. Three-dimensional finite analysis of acetabular contact pressure and contact area during normal walking.

    PubMed

    Wang, Guangye; Huang, Wenjun; Song, Qi; Liang, Jinfeng

    2017-11-01

    This study aims to analyze the contact areas and pressure distributions between the femoral head and mortar during normal walking using a three-dimensional finite element model (3D-FEM). Computed tomography (CT) scanning technology and a computer image processing system were used to establish the 3D-FEM. The acetabular mortar model was used to simulate the pressures during 32 consecutive normal walking phases and the contact areas at different phases were calculated. The distribution of the pressure peak values during the 32 consecutive normal walking phases was bimodal, which reached the peak (4.2 Mpa) at the initial phase where the contact area was significantly higher than that at the stepping phase. The sites that always kept contact were concentrated on the acetabular top and leaned inwards, while the anterior and posterior acetabular horns had no pressure concentration. The pressure distributions of acetabular cartilage at different phases were significantly different, the zone of increased pressure at the support phase distributed at the acetabular top area, while that at the stepping phase distributed in the inside of acetabular cartilage. The zones of increased contact pressure and the distributions of acetabular contact areas had important significance towards clinical researches, and could indicate the inductive factors of acetabular osteoarthritis. Copyright © 2016. Published by Elsevier Taiwan.

  9. Debonding of porous coating of a threaded acetabular component: retrieval analysis.

    PubMed

    Łapaj, Łukasz; Markuszewski, Jacek; Rybak, Tomasz; Wierusz-Kozłowska, Małgorzata

    2013-01-01

    This report presents a case of debonding of plasma sprayed porous titanium coating from a threaded acetabular component which caused aseptic loosening of the implant. Weight bearing after delamination caused abrasive damage of the acetabular shell, and particles of the coating embedded in the acetabular liner. Microscopic examination of periprosthetic tissues showed presence of metal particles and macrophage infiltration. Despite microscopic examination of the retrieved component the cause of debonding remains unclear. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Outcome of bone marrow instillation at fracture site in intracapsular fracture of femoral neck treated by head preserving surgery.

    PubMed

    Verma, Nikhil; Singh, M P; Ul-Haq, Rehan; Rajnish, Rajesh K; Anshuman, Rahul

    2017-08-01

    The aim of present study is to evaluate the outcome of bone marrow instillation at the fracture site in fracture of intracapsular neck femur treated by head preserving surgery. This study included 32 patients of age group 18-50 years with closed fracture of intracapsular neck femur. Patients were randomized into two groups as per the plan generated via www.randomization.com. The two groups were Group A (control), in which the fracture of intracapsular neck femur was treated by closed reduction and cannulated cancellous screw fixation, and Group B (intervention), in which additional percutaneous autologous bone marrow aspirate instillation at fracture site was done along with cannulated cancellous screw fixation. Postoperatively the union at fracture site and avascular necrosis of the femoral head were assessed on serial plain radiographs at final follow-up. Functional outcome was evaluated by Harris hip score. The average follow-up was 19.6 months. Twelve patients in each group had union and 4 patients had signs of nonunion. One patient from each group had avascular necrosis of the femoral head. The average Harris hip score at final follow-up in Group A was 80.50 and in Group B was 75.73, which was found to be not significant. There is no significant role of adding on bone marrow aspirate instillation at the fracture site in cases of fresh fracture of intracapsular neck femur treated by head preserving surgery in terms of accelerating the bone healing and reducing the incidence of femoral head necrosis. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  11. Predictive value of clinical scoring and simplified gait analysis for acetabulum fractures.

    PubMed

    Braun, Benedikt J; Wrona, Julian; Veith, Nils T; Rollman, Mika; Orth, Marcel; Herath, Steven C; Holstein, Jörg H; Pohlemann, Tim

    2016-12-01

    Fractures of the acetabulum show a high, long-term complication rate. The aim of the present study was to determine the predictive value of clinical scoring and standardized, simplified gait analysis on the outcome after these fractures. Forty-one patients with acetabular fractures treated between 2008 and 2013 and available, standardized video recorded aftercare were identified from a prospective database. A visual gait score was used to determine the patients walking abilities 6-m postoperatively. Clinical (Merle d'Aubigne and Postel score, visual analogue scale pain, EQ5d) and radiological scoring (Kellgren-Lawrence score, postoperative computed tomography, and Matta classification) were used to perform correlation and multivariate regression analysis. The average patient age was 48 y (range, 15-82 y), six female patients were included in the study. Mean follow-up was 1.6 y (range, 1-2 y). Moderate correlation between the gait score and outcome (versus EQ5d: r s  = 0.477; versus Merle d'Aubigne: r s  = 0.444; versus Kellgren-Lawrence: r s  = -0.533), as well as high correlation between the Merle d'Aubigne score and outcome were seen (versus EQ5d: r s  = 0.575; versus Merle d'Aubigne: r s  = 0.776; versus Kellgren-Lawrence: r s  = -0.419). Using a multivariate regression model, the 6 m gait score (B = -0.299; P < 0.05) and early osteoarthritis development (B = 1.026; P < 0.05) were determined as predictors of final osteoarthritis. A good fit of the regression model was seen (R 2  = 904). Easy and available clinical scoring (gait score/Merle d'Aubigne) can predict short-term radiological and functional outcome after acetabular fractures with sufficient accuracy. Decisions on further treatment and interventions could be based on simplified gait analysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Bone preserving techniques for explanting the well-fixed cemented acetabular component.

    PubMed

    Stevens, Jarrad; Macpherson, Gavin; Howie, Colin

    2018-06-01

    Removal of a well-fixed, cemented acetabular component at the time of revision hip surgery can be complex. It is essential to remove the implant and cement mantle in a timely fashion while preserving bone stock and osseous integrity. The biomechanical properties of polymethylmethacrylate cement and polyethylene can be utilised to aid with the removal of well cemented implants which are often harder than the surrounding bone. While removal of loose components may be relatively straightforward, the challenge for the revision arthroplasty surgeon often involves the removal of well-fixed implants. Here, we present three established techniques for the removal of a well-fixed cemented acetabular component and one novel modification we have described before. We collate and review four techniques for removing well-fixed cemented acetabular implants that utilise the different biomechanical properties of bone cement and polyethylene. These techniques are illustrated with a photographic series utilising saw bones. A step-by-step approach to our new technique is shown in photographs, both in the clinical setting and with a "Sawbone". This is accompanied by a clinical video that details the surgical technique in its entirety. These techniques utilise different biomechanical principles to extract the acetabular component. Each technique has advantages and disadvantages. Our new technique is a simplification of a previously published extraction manoeuvre that utilises tensile force between cement and the implant to remove the polyethylene cup. This is a safe and reproducible technique in patients with a well-fixed cemented acetabular implant. Understanding the biomechanical properties of polymethylmethacrylate bone cement and polyethylene can aid in the safe removal of a well-fixed cemented acetabular component in revision hip surgery. The optimal technique for removal of a cemented acetabular component varies depending on a number of patient and implant factors. This summary of

  13. Effects of Titanium Mesh Surfaces-Coated with Hydroxyapatite/β-Tricalcium Phosphate Nanotubes on Acetabular Bone Defects in Rabbits

    PubMed Central

    Nguyen, Thuy-Duong Thi; Bae, Tae-Sung; Yang, Dae-hyeok; Park, Myung-sik; Yoon, Sun-jung

    2017-01-01

    The management of severe acetabular bone defects in revision reconstructive orthopedic surgery is challenging. In this study, cyclic precalcification (CP) treatment was used on both nanotube-surface Ti-mesh and a bone graft substitute for the acetabular defect model, and its effects were assessed in vitro and in vivo. Nanotube-Ti mesh coated with hydroxyapatite/β-tricalcium phosphate (HA/β-TCP) was manufactured by an anodizing and a sintering method, respectively. An 8 mm diameter defect was created on each acetabulum of eight rabbits, then treated by grafting materials and covered by Ti meshes. At four and eight weeks, postoperatively, biopsies were performed for histomorphometric analyses. The newly-formed bone layers under cyclic precalcified anodized Ti (CP-AT) meshes were superior with regard to the mineralized area at both four and eight weeks, as compared with that under untreated Ti meshes. Active bone regeneration at 2–4 weeks was stronger than at 6–8 weeks, particularly with treated biphasic ceramic (p < 0.05). CP improved the bioactivity of Ti meshes and biphasic grafting materials. Moreover, the precalcified nanotubular Ti meshes could enhance early contact bone formation on the mesh and, therefore, may reduce the collapse of Ti meshes into the defect, increasing the sufficiency of acetabular reconstruction. Finally, cyclic precalcification did not affect bone regeneration by biphasic grafting materials in vivo. PMID:28686210

  14. Low-dose CT of postoperative pelvic fractures: a comparison with radiography.

    PubMed

    Eriksson, Thomas; Berg, Per; Olerud, Claes; Shalabi, Adel; Hänni, Mari

    2018-01-01

    Background Computed tomography (CT) is superior to conventional radiography (CR) for assessing internal fixation of pelvic fractures, but with a higher radiation exposure. Low-dose CT (LDCT) could possibly have a sufficient diagnostic accuracy but with a lower radiation dose. Purpose To compare postoperative diagnostic accuracy of LDCT and CR after open reduction and internal fixation of pelvic fracture. Material and Methods Twenty-one patients were examined with LDCT and CR 0-9 days after surgery. The examinations were reviewed by two musculoskeletal radiologists. Hardware, degree of fracture reduction, image quality, and reviewing time were assessed, and effective radiation dose was calculated. Inter-reader agreement was calculated. Results LDCT was significantly better than CR in determining whether hardware positioning was assessable ( P < 0.001). Acetabular congruence was assessable in all fractured patients with LDCT. In 12 of the 32 assessments with CR of patients with an acetabular fracture, joint congruence was not assessable due to overlapping hardware ( P = 0.001). Image quality was significantly higher for LDCT. Median time to review was 240 s for LDCT compared to 180 s for CR. Effective dose was 0.79 mSv for LDCT compared to 0.32 mSv for CR ( P < 0.001). Conclusion LDCT is more reliable than CR in assessing hardware position and fracture reduction. Joint congruency is sometimes not possible to assess with CR, due to overlapping hardware. The image quality is higher, but also the effective dose, with LDCT than with CR.

  15. Outcome of surgically treated non-missile traumatic depressed skull fracture.

    PubMed

    Nnadi, M O N; Bankole, O B; Arigbabu, S O

    2014-12-01

    To determine the functional outcome and infection rate in patients who were surgically treated for non-missile traumatic depressed skull fractures. It is a prospective cross-sectional descriptive study carried out on computerised tomography scanned depressed skull fractures surgically treated in Lagos University Teaching Hospital, Lagos from October 2008 to September 2009. Data were collected using structured proforma in accident and emergency, theatre, wards, and in outpatient clinic. Data collected included age, gender, occupation, type of depressed fracture, aetiology, clinicaland radiological findings, type of surgery done, complications, and outcome of treatment. Data was analysed using EPI info 2002 software. A total of 17 patients were studied. There were 12males and 5females. Fifteen (88.2%) of the patients were0- 40years. The aetiology was road traffic accident in 82.4% of cases. Fourteen (82.4%) of the patients had open depressed skull fractures, while 17.6% had closed depressed skull fractures. Five (29.4%) of the patients had wound infection. Two (22.2%) of thepatients operated within 48hours had wound infection, while 37.5% of those operated after 48hours had wound infection. There was no infection among patients who had primary bone fragments replaced. Fifteen (88.2%) of the patients had good functional outcome. The functional outcome in this study is good but the infection rate is high. Primary bone fragments should be replaced whenever possible as it prevents the need for cranioplasty and there is no relative risk of increased infection rate.

  16. Fractures of the distal tibia treated with polyaxial locking plating.

    PubMed

    Gao, Hong; Zhang, Chang-Qing; Luo, Cong-Feng; Zhou, Zu-Bin; Zeng, Bing-Fang

    2009-03-01

    We evaluated the healing rate, complications, and functional outcomes in 32 adult patients with very short metaphyseal fragments in fractures of the distal tibia treated with a polyaxial locking system. The average distance from the distal extent of the fracture to the tibial plafond was 11 mm. All fractures healed and the average time to union was 14 weeks. Six patients (19%) reported occasional local disturbance over the medial malleolus. There were two cases of postoperative superficial infections and evidence of delayed wound healing. Using the American Orthopaedic Foot and Ankle Society ankle score, the average functional score was 87.3 points (of 100 total possible points). Our results show the polyaxial locking plates, which offer more fixation versatility, may be a reasonable treatment option for distal tibia fractures with very short metaphyseal segments.

  17. When do anterior external or internal fixators provide additional stability in an unstable (Tile C) pelvic fracture? A biomechanical study.

    PubMed

    Mcdonald, E; Theologis, A A; Horst, P; Kandemir, U; Pekmezci, M

    2015-12-01

    This study aimed at evaluating the additional stability that is provided by anterior external and internal fixators in an unstable pelvic fracture model (OTA 61-C). An unstable pelvic fracture (OTA 61-C) was created in 27 synthetic pelves by making a 5-mm gap through the sacral foramina (posterior injury) and an ipsilateral pubic rami fracture (anterior injury). The posterior injury was fixed with either a single iliosacral (IS) screw, a single trans-iliac, trans-sacral (TS) screw, or two iliosacral screws (S1S2). Two anterior fixation techniques were utilized: external fixation (Ex-Fix) and supra-acetabular external fixation and internal fixation (In-Fix); supra-acetabular pedicle screws connected with a single subcutaneous spinal rod. The specimens were tested using a nondestructive single-leg stance model. Peak-to-peak (P2P) displacement and rotation and conditioning displacement (CD) were calculated. The Ex-Fix group failed in 83.3 % of specimens with concomitant single-level posterior fixation (Total: 15/18-7 of 9 IS fixation, 8 of 9 TS fixation), and 0 % (0/9) of specimens with concomitant two-level (S1S2) posterior fixation. All specimens with the In-Fix survived testing except for two specimens treated with In-Fix combined with IS fixation. Trans-sacral fixation had higher pubic rotation and greater sacral and pubic displacement than S1S2 (p < 0.05). Rotation of the pubis and sacrum was not different between In-Fix constructs combined with single-level IS and TS fixation. In this model of an unstable pelvic fracture (OTA 61-C), anterior fixation with an In-Fix was biomechanically superior to an anterior Ex-Fix in the setting of single-level posterior fixation. There was no biomechanical difference between the In-Fix and Ex-Fix when each was combined with two levels of posterior sacral fixation.

  18. Validity and reliability of the Paprosky acetabular defect classification.

    PubMed

    Yu, Raymond; Hofstaetter, Jochen G; Sullivan, Thomas; Costi, Kerry; Howie, Donald W; Solomon, Lucian B

    2013-07-01

    The Paprosky acetabular defect classification is widely used but has not been appropriately validated. Reliability of the Paprosky system has not been evaluated in combination with standardized techniques of measurement and scoring. This study evaluated the reliability, teachability, and validity of the Paprosky acetabular defect classification. Preoperative radiographs from a random sample of 83 patients undergoing 85 acetabular revisions were classified by four observers, and their classifications were compared with quantitative intraoperative measurements. Teachability of the classification scheme was tested by dividing the four observers into two groups. The observers in Group 1 underwent three teaching sessions; those in Group 2 underwent one session and the influence of teaching on the accuracy of their classifications was ascertained. Radiographic evaluation showed statistically significant relationships with intraoperative measurements of anterior, medial, and superior acetabular defect sizes. Interobserver reliability improved substantially after teaching and did not improve without it. The weighted kappa coefficient went from 0.56 at Occasion 1 to 0.79 after three teaching sessions in Group 1 observers, and from 0.49 to 0.65 after one teaching session in Group 2 observers. The Paprosky system is valid and shows good reliability when combined with standardized definitions of radiographic landmarks and a structured analysis. Level II, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.

  19. The Transverse Acetabular Ligament as an Intraoperative Guide to Cup Abduction.

    PubMed

    Hiddema, Willem B; van der Merwe, Johan F; van der Merwe, Werner

    2016-07-01

    The success of a total hip arthroplasty relies on optimal acetabular cup placement to ensure mating of the femoral head and acetabular cup throughout all positions of the hip joint. Poor cup placement is associated with dislocation, impingement, microseparation, component loosening, and accelerated wear due to rim loading. This study examined a novel method of using the transverse acetabular ligament (TAL) to guide cup inclination during primary total hip arthroplasty. A descriptive study using 16 hips from 9 cadavers. A computer navigation system measured inclination and version of the acetabular component in 3 positions with the lower edge of cup: (1) flush with, (2) 5 mm proximal to, and (3) 5 mm distal to free border of the TAL. The median inclination angles were 44° in position (1), 30° in position (2), and 64° in position (3). The median anteversion angle for all positions was 19°. Cup inclination was acceptable when the lower edge of the cup was flush or within 5 mm proximal to the TAL. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Application of biodegradable plates for treating pediatric mandibular fractures.

    PubMed

    An, Jingang; Jia, Pengcheng; Zhang, Yi; Gong, Xi; Han, Xiaodong; He, Yang

    2015-05-01

    We assessed the clinical results of a biodegradable plate system for the internal fixation of mandibular fractures in children, and observed the imaging features of fracture healing and bone changes around the biodegradable plates and screws during follow-up. We enrolled 39 patients (22 male, 17 female, average age 4 years 10 months) with different mandibular fractures. We used 2.0-mm resorbable plates to repair the fractures. Postoperative follow-up ranged from 6 months to 5 years; average follow-up was 1 year 2 months. The outcome measures identified and assessed included facial symmetry, mouth opening, occlusal relationship, infection, nonunion, malunion, and plate dehiscence. We fixed 42 fractures with 43 resorbable plates; the fracture site of one patient (aged 11 years 3 months) was fixed with two plates. Two patients developed small fistulas at the intraoral incision 2 months after surgery; the fistulas healed after 1 month without special treatment. In the other patients, the incision healed well, there was facial symmetry, mouth opening was >35 mm, and occlusion was good. Follow-up computed tomography examination data were available for 20 cases, and revealed different degrees of radiolucency indicating that osteolysis had occurred. Radiolucency was observed around the resorbable plates 1 month after the surgery. The extent and depth of the radiolucent region were obvious within 1 year of surgery. In the second year, there were obvious repairs, with the bony defect areas becoming shallower. After 2 years, the bony defect areas had almost disappeared. Biodegradable fixation devices are safe and efficient for treating pediatric mandibular fractures. Osteolysis commonly follows biodegradable fixation of pediatric mandibular fractures, and has no adverse effect on fracture healing. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Comparing hospital outcomes between open and closed tibia fractures treated with intramedullary fixation.

    PubMed

    Smith, Evan J; Kuang, Xiangyu; Pandarinath, Rajeev

    2017-07-01

    Tibial shaft fractures comprise a large portion of operatively treated long bone fractures, and present with the highest rate of open injuries. Intramedullary fixation has become the standard of care for both open and closed injuries. The rates of short term complications and hospital length of stay for open and closed fractures treated with intramedullary fixation is not fully known. Previous series on tibia fractures were performed at high volume centers, and data were not generalizable, further they did not report on length of stay and the impact of preoperative variables on infections, complications and reoperation. We used a large surgical database to compare these outcomes while adjusting for preoperative risk factors. Data were extracted from the ACS-NSQIP database from 2005 to 2014. Cases were identified based on CPT codes for intramedullary fixation and categorized as closed vs open based on ICD9 code. In addition to demographic and case data, primary analysis examined correlation between open and closed fracture status with infection, complications, reoperation and hospital length of stay. Secondary analysis examined preoperative variables including gender, race, age, BMI, and diabetes effect on outcomes. There were 272 cases identified. There were no significant demographic differences between open and closed tibia fracture cases. Open fracture status did not increase the rate of infection, 30day complications, reoperation, or length of stay. The only preoperative factor that correlated with length of stay was age. There was no correlation between BMI, presence of insulin dependent and nondependent diabetes, and any outcome measure. When considering the complication rates for open and closed tibial shaft fractures treated with intramedullary fixation, there is no difference between 30-day complication rate, length of stay, or return to the operating room. Our reported postoperative infection rates were comparable to previous series, adding validity to

  2. Distal tibial fractures and non-unions treated with shortened intramedullary nail.

    PubMed

    Megas, P; Zouboulis, P; Papadopoulos, A X; Karageorgos, A; Lambiris, E

    2003-01-01

    We reviewed 18 patients, 14 with acute fractures and four with non-union of the distal tibia, treated between 1990 and 2001 with a shortened, reamed intramedullary nail. The mean follow-up was 38 (8-144) months. The fractures united at an average of 16 (12-18) weeks and the non-unions at 20 (12-30) weeks. Two patients required nail dynamization. No limb shortening nor material failures were seen. All patients returned to normal daily activities. Although technically demanding, intramedullary nailing for distal tibial fractures and non-unions with a shortened nail represents a safe and reliable method.

  3. Sacroiliac joint dysfunction as a reason for the development of acetabular retroversion: a new theory.

    PubMed

    Cibulka, Michael T

    2014-05-01

    Acetabular retroversion has been recently implicated as an important factor in the development of femoral acetabular impingement and hip osteoarthritis. The proper function of the hip joint requires that the anatomic features of the acetabulum and femoral head complement one another. In acetabular retroversion, the alignment of the acetabulum is altered where it opens in a posterolaterally instead of anterior direction. Changes in acetabular orientation can occur with alterations in pelvic tilt (anterior/posterior), and pelvic rotation (left/right). An overlooked problem that alters pelvic tilt and rotation, often seen by physical therapists, is sacroiliac joint dysfunction. A unique feature that develops in patients with sacroiliac joint dysfunction (SIJD) is asymmetry between the left and right innominate bones that can alter pelvic tilt and rotation. This article puts forth a theory suggesting that acetabular retroversion may be produced by sacroiliac joint dysfunction.

  4. Fractures in women treated with raloxifene or alendronate: a retrospective database analysis

    PubMed Central

    2013-01-01

    Background Raloxifene and alendronate are anti-resorptive therapies approved for the prevention and treatment of postmenopausal osteoporosis. Raloxifene is also indicated to reduce the risk of invasive breast cancer in postmenopausal women with osteoporosis and in postmenopausal women at high risk of invasive breast cancer. A definitive study comparing the fracture effectiveness and rate of breast cancer for raloxifene and alendronate has not been published. The purpose of this retrospective cohort study was to evaluate fracture and breast cancer rates among patients treated with raloxifene or alendronate. Methods Females ≥45 years who initiated raloxifene or alendronate in 1998–2006 Truven Health Analytics MarketScan® Databases, had continuous enrollment 12 months prior to and at least 12 months after the index date, and had a treatment medication possession ratio ≥80% were included in this study. Rates of vertebral and nonvertebral fractures and breast cancer during 1, 3, 5, 6, 7, and 8 years of treatment with raloxifene or alendronate were evaluated. Fracture rates were adjusted for potential treatment bias using inverse probability of treatment weights. Multivariate hazard ratios were estimated for vertebral and nonvertebral fractures. Results Raloxifene patients had statistically significantly lower rates of vertebral fractures in 1, 3, 5, and 7 years and for nonvertebral fractures in 1 and 5 years. There were no statistically significant differences in the adjusted fracture rates between raloxifene and alendronate cohorts, except in the 3-year nonvertebral fracture rates where raloxifene was higher. Multivariate hazard ratios of raloxifene versus alendronate cohorts were not significantly different for vertebral and nonvertebral fracture in 1, 3, 5, 6, 7, and 8 years. Unweighted and weighted breast cancer rates were lower among raloxifene recipients. Conclusions Patients treated with alendronate and raloxifene had similar adjusted

  5. Is anatomic acetabular orientation related to pelvic morphology? CT analysis of 150 healthy pelvises.

    PubMed

    Sautet, P; Giorgi, H; Chabrand, P; Tropiano, P; Argenson, J-N; Parratte, S; Blondel, B

    2018-05-01

    Links between sagittal spinal alignment and acetabular orientation attract considerable research attention with the goal of optimising prosthetic cup position. However, whether pelvic incidence (PI) is related to anatomic acetabular orientation remains unknown. We therefore conducted a radiological study with the following objectives: to look for correlations between PI and anatomic acetabular parameters; to describe the sacro-pubic angle (SPA), defined by fixed bony pelvic landmarks, and its relations with acetabular anteversion; and to determine whether anatomical parameters (PI and SPA) correlate with demographic characteristics. PI correlates with anatomical acetabular parameters. We conducted a computed tomography (CT) study of the pelvises of 150 patients free of degenerative disease. Three parameters were measured: anatomic acetabular orientation in the Lewinnek reference plane, PI, and the SPA subtended by the line connecting the midpoint of the sacral endplate to the pubic symphysis and the anterior pelvic plane. Statistical tests were performed to look for correlations among these parameters. Intra-observer and inter-observer reproducibility was considered highly satisfactory (inter-class correlation coefficient, >86% and >82%, respectively). Mean PI was 58.6°±10.2° (range, 32.8°-97.6°), with no significant differences between genders or across age groups. Mean SPA was 34.7°±5.5° (range, 18.3°-49.8°). Mean anatomic acetabular anteversion (AAA) was greater in females (23.4°; range, 11.5°-34.5°) than in males (20°; range, 7.5°-34.5°) (P<0.001). PI did not correlate with any of the acetabular parameters (PI/AAA, r=0.8 and P=0.33; PI/acetabular inclination on the horizontal, r=-0.96 and P=0.24). SPA correlated significantly with both PI (r=0.33 and P<0.001) and AAA (r=0.33 and P<0.001). This CT study of normal pelvises showed that AAA was significantly greater in females and that SPA correlated significantly with both PI and acetabular

  6. A Novel Fixation System for Acetabular Quadrilateral Plate Fracture: A Comparative Biomechanical Study

    PubMed Central

    Zha, Guo-Chun; Sun, Jun-Ying; Dong, Sheng-Jie; Zhang, Wen; Luo, Zong-Ping

    2015-01-01

    This study aims to assess the biomechanical properties of a novel fixation system (named AFRIF) and to compare it with other five different fixation techniques for quadrilateral plate fractures. This in vitro biomechanical experiment has shown that the multidirectional titanium fixation (MTF) and pelvic brim long screws fixation (PBSF) provided the strongest fixation for quadrilateral plate fracture; the better biomechanical performance of the AFRIF compared with the T-shaped plate fixation (TPF), L-shaped plate fixation (LPF), and H-shaped plate fixation (HPF); AFRIF gives reasonable stability of treatment for quadrilateral plate fracture and may offer a better solution for comminuted quadrilateral plate fractures or free floating medial wall fracture and be reliable in preventing protrusion of femoral head. PMID:25802849

  7. Interobserver reliability of the young-burgess and tile classification systems for fractures of the pelvic ring.

    PubMed

    Koo, Henry; Leveridge, Mike; Thompson, Charles; Zdero, Rad; Bhandari, Mohit; Kreder, Hans J; Stephen, David; McKee, Michael D; Schemitsch, Emil H

    2008-07-01

    The purpose of this study was to measure interobserver reliability of 2 classification systems of pelvic ring fractures and to determine whether computed tomography (CT) improves reliability. The reliability of several radiographic findings was also tested. Thirty patients taken from a database at a Level I trauma facility were reviewed. For each patient, 3 radiographs (AP pelvis, inlet, and outlet) and CT scans were available. Six different reviewers (pelvic and acetabular specialist, orthopaedic traumatologist, or orthopaedic trainee) classified the injury according to Young-Burgess and Tile classification systems after reviewing plain radiographs and then after CT scans. The Kappa coefficient was used to determine interobserver reliability of these classification systems before and after CT scan. For plain radiographs, overall Kappa values for the Young-Burgess and Tile classification systems were 0.72 and 0.30, respectively. For CT scan and plain radiographs, the overall Kappa values for the Young-Burgess and Tile classification systems were 0.63 and 0.33, respectively. The pelvis/acetabular surgeons demonstrated the highest level of agreement using both classification systems. For individual questions, the addition of CT did significantly improve reviewer interpretation of fracture stability. The pre-CT and post-CT Kappa values for fracture stability were 0.59 and 0.93, respectively. The CT scan can improve the reliability of assessment of pelvic stability because of its ability to identify anatomical features of injury. The Young-Burgess system may be optimal for the learning surgeon. The Tile classification system is more beneficial for specialists in pelvic and acetabular surgery.

  8. Acetabular cartilage defects cause altered hip and knee joint coordination variability during gait.

    PubMed

    Samaan, Michael A; Teng, Hsiang-Ling; Kumar, Deepak; Lee, Sonia; Link, Thomas M; Majumdar, Sharmila; Souza, Richard B

    2015-12-01

    Patients with acetabular cartilage defects reported increased pain and disability compared to those without acetabular cartilage defects. The specific effects of acetabular cartilage defects on lower extremity coordination patterns are unclear. The purpose of this study was to determine hip and knee joint coordination variability during gait in those with and without acetabular cartilage defects. A combined approach, consisting of a semi-quantitative MRI-based quantification method and vector coding, was used to assess hip and knee joint coordination variability during gait in those with and without acetabular cartilage lesions. The coordination variability of the hip flexion-extension/knee rotation, hip abduction-adduction/knee rotation, and hip rotation/knee rotation joint couplings were reduced in the acetabular lesion group compared to the control group during loading response of the gait cycle. The lesion group demonstrated increased variability in the hip flexion-extension/knee rotation and hip abduction-adduction/knee rotation joint couplings, compared to the control group, during the terminal stance/pre-swing phase of gait. Reduced variability during loading response in the lesion group may suggest reduced movement strategies and a possible compensation mechanism for lower extremity instability during this phase of the gait cycle. During terminal stance/pre-swing, a larger variability in the lesion group may suggest increased movement strategies and represent a compensation or pain avoidance mechanism caused by the load applied to the hip joint. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Rush Fracture Liaison Service for capturing "missed opportunities" to treat osteoporosis in patients with fragility fractures.

    PubMed

    Gupta, M J; Shah, S; Peterson, S; Baim, S

    2018-06-04

    In spite of being a public health problem of pandemic proportions, osteoporosis continues to be underdiagnosed and undertreated especially in older adults with fragility fractures. Confirmation of this hypothesis resulted in the development of a novel Fracture Liaison Service (Rush FLS). Results of the first 12 months of operation revealed that patients with confirmed fragility fracture do not have a timely diagnosis at fracture occurrence or treatment of their disease. The Rush FLS is an effective fracture liaison model. Determining the prevalence of undiagnosed and untreated osteoporosis in fragility fracture patients, either admitted to an academic tertiary care center or treated and discharged from the center's emergency department to be followed in the endocrinology bone clinic, using an innovative, educational, low-cost, physician-run Fracture Liaison Service (FLS). An automated alert was integrated into the electronic medical record at Rush University Medical Center (RUMC), triggered by historical and/or acute fracture(s) in patients 50 years or older, in patients that were either admitted to the hospital or in patients evaluated in the emergency department and discharged to be followed in the endocrinology bone clinic. We report the results of the first 12 months of operation in patients admitted to the hospital. First acute fragility fracture(s) were identified in 36% (80/223), only historical fragility fracture(s) in 28% (63/223) and both acute and historical fragility fracture(s) in 36% (80/223). The cumulative subgroup with historical fragility fractures with/without new fractures included 67% (96/143) without a previous diagnosis of osteoporosis. First acute fragility fracture group included 83.8% (67/80) without a previous diagnosis of osteoporosis. Rush FLS "captured missed opportunities" in 73.1% (163/223) of previously undiagnosed and 77.1% (172/223) of previously untreated osteoporosis patients. Dual-energy x-ray absorptiometry (DXA) prior to

  10. Magnetic resonance imaging with gadolinium arthrography to assess acetabular cartilage delamination.

    PubMed

    Zaragoza, Edward; Lattanzio, Pierre-Jean; Beaule, Paul E

    2009-01-01

    Recent reports have demonstrated magnetic resonance imaging (MRI) as a promising technique in detecting articular cartilage lesions of the hip joint. The purpose of our study was to evaluate the diagnostic performance of MRI with gadolinium arthrography in detecting acetabular cartilage delamination in patients with pre-arthritic hip pain. 46 patients (48 hips) underwent surgical dislocation of the hip. Mean age was 38.8 (range 17-56). There were 26 males and 20 females. All patients had Magnetic Resonance Imaging with gadolinium arthrography (MRA) before undergoing open hip surgery where the acetabular cartilage was inspected. Acetabular cartilage delamination on MRA was seen on sagittal images as a linear intra-articular filling defect of low signal intensity >1mm in thickness on T1 weighted images and surrounded by contrast. On MRA all hips had a labral tear confirmed at surgery. At surgery 30 hips had evidence of acetabular cartilage delamination, 4 hips had ulceration and 14 had no articular cartilage damage. The majority of labral tears and cartilage damage were located in the antero-superior quadrant. The sensitivity and specificity of MRA detection of cartilage delamination confirmed at surgery were 97% and 84%, respectively. The positive and negative predictive values of the MRA finding were 90% and 94%, respectively. The presence of the acetabular cartilage delamination represents an early stage of articular cartilage degeneration. When evaluating a young adult with hip pain, labral tears in association with cartilage delamination should be considered. MRA represents an effective diagnostic tool.

  11. Effects of fiber-glass-reinforced composite restorations on fracture resistance and failure mode of endodontically treated molars.

    PubMed

    Nicola, Scotti; Alberto, Forniglia; Riccardo, Michelotto Tempesta; Allegra, Comba; Massimo, Saratti Carlo; Damiano, Pasqualini; Mario, Alovisi; Elio, Berutti

    2016-10-01

    The study evaluated the fracture resistance and fracture patterns of endodontically treated mandibular first molars restored with glass-fiber-reinforced direct composite restorations. In total, 60 extracted intact first molars were treated endodontically; a mesio-occluso-distal (MOD) cavity was prepared and specimens were then divided into six groups: sound teeth (G1), no restoration (G2), direct composite restoration (G3), fiber-post-supported direct composite restoration (G4), direct composite reinforced with horizontal mesio-distal glass-fibers (G5), and buccal-palatal glass-fibers (G6). Specimens were subjected to 5000 thermocycles and 20,000 cycles of 45° oblique loading force at 1.3Hz and 50N; they were then loaded until fracture. The maximum fracture loads were recorded in Newtons (N) and data were analyzed with one-way ANOVA and post-hoc Tukey tests (p<0.05). Fractured specimens were analyzed with a scanning electron microscope (SEM). The mean static loads (in Newtons) were: G1, 831.83; G2, 282.86; G3, 364.18; G4, 502.93; G5, 499.26; and G6, 582.22. Fracture resistance did not differ among G4, G5, and G6, but was significantly higher than G3 (p=0.001). All specimens fractured in a catastrophic way. In G6, glass fibers inducted a partial deflection of the fracture, although they were not able to stop crack propagation. For the direct restoration of endodontically treated molars, reinforcement of composite resins with glass-fibers or fiber posts can enhance fracture resistance. The SEM analysis showed a low ability of horizontal glass-fibers to deviate the fracture, but this effect was not sufficient to lead to more favorable fracture patterns above the cement-enamel junction (CEJ). The fracture resistance of endodontically treated molars restored with direct composite restorations seems to be increased by reinforcement with fibers, even if it is insufficient to restore sound molar fracture resistance and cannot avoid vertical fractures. Copyright © 2016

  12. Cement-in-cement acetabular revision with a constrained tripolar component.

    PubMed

    Leonidou, Andreas; Pagkalos, Joseph; Luscombe, Jonathan

    2012-02-17

    Dislocation of a total hip replacement (THR) is common following total hip arthroplasty (THA). When nonoperative management fails to maintain reduction, revision surgery is considered. The use of constrained acetabular liners has been extensively described. Complete removal of the old cement mantle during revision THA can be challenging and is associated with significant complications. Cement-in-cement revision is an established technique. However, the available clinical and experimental studies focus on femoral stem revision. The purpose of this study was to present a case of cement-in-cement acetabular revision with a constrained component for recurrent dislocations and to investigate the current best evidence for this technique. This article describes the case of a 74-year-old woman who underwent revision of a Charnley THR for recurrent low-energy dislocations. A tripolar constrained acetabular component was cemented over the primary cement mantle following removal of the original liner by reaming, roughening the surface, and thoroughly irrigating and drying the primary cement. Clinical and radiological results were good, with the Oxford Hip Score improving from 11 preoperatively to 24 at 6 months postoperatively. The good short-term results of this case and the current clinical and biomechanical data encourage the use of the cement-in-cement technique for acetabular revision. Careful irrigation, drying, and roughening of the primary surface are necessary. Copyright 2012, SLACK Incorporated.

  13. Should fractures in massive intercalary bone allografts of the lower limb be treated with ORIF or with a new allograft?

    PubMed

    Aponte-Tinao, Luis A; Ayerza, Miguel A; Muscolo, D Luis; Farfalli, Germán L

    2015-03-01

    Massive bone allografts have been used for limb salvage of bone tumor resections as an alternative to endoprostheses, although they have different outcomes and risks. There is no general consensus about when to use these alternatives, but when it is possible to save the native joints after the resection of a long bone tumor, intercalary allografts offer some advantages despite complications, such as fracture. The management and outcomes of this complication deserve more study. The purposes of this study were to (1) analyze the fracture frequency in a group of patients treated with massive intercalary bone allografts of the femur and tibia; (2) compare the results of allografts treated with open reduction and internal fixation (ORIF) with those treated with resection and repeat allograft reconstruction; and (3) determine the likelihood that treatment of a fracture resulted in a healed intercalary reconstruction. We reviewed patients treated with intercalary bone allografts between 1991 and 2011. During this period, patients were generally treated with intercalary allografts when after tumor resection at least 1 cm of residual epiphysis remained to allow fixation of the osteotomy junction. To obtain a homogeneous group of patients, we excluded allograft-prosthesis composites and osteoarticular and hemicylindrical intercalary allografts from this study. We analyzed the fracture rate of 135 patients reconstructed with segmental intercalary bone allografts of the lower extremities (98 femurs and 37 tibias). In patients whose grafts fractured were treated either by internal fixation or a second allograft, ORIF generally was attempted but after early failures in femur fractures, these fractures were treated with a second allograft. Using a chart review, we ascertained the frequency of osseous union, complications, and reoperations after the treatment of fractured intercalary allografts. Followup was at a mean of 101 months (range, 24-260 months); of the original 135

  14. Pelvic incidence: a predictive factor for three-dimensional acetabular orientation-a preliminary study.

    PubMed

    Boulay, Christophe; Bollini, Gérard; Legaye, Jean; Tardieu, Christine; Prat-Pradal, Dominique; Chabrol, Brigitte; Jouve, Jean-Luc; Duval-Beaupère, Ginette; Pélissier, Jacques

    2014-01-01

    Acetabular cup orientation (inclination and anteversion) is a fundamental topic in orthopaedics and depends on pelvis tilt (positional parameter) emphasising the notion of a safe range of pelvis tilt. The hypothesis was that pelvic incidence (morphologic parameter) could yield a more accurate and reliable assessment than pelvis tilt. The aim was to find out a predictive equation of acetabular 3D orientation parameters which were determined by pelvic incidence to include in the model. The second aim was to consider the asymmetry between the right and left acetabulae. Twelve pelvic anatomic specimens were measured with an electromagnetic Fastrak system (Polhemus Society) providing 3D position of anatomical landmarks to allow measurement of acetabular and pelvic parameters. Acetabulum and pelvis data were correlated by a Spearman matrix. A robust linear regression analysis provided prediction of acetabulum axes. The orientation of each acetabulum could be predicted by the incidence. The incidence is correlated with the morphology of acetabula. The asymmetry of the acetabular roof was correlated with pelvic incidence. This study allowed analysis of relationships of acetabular orientation and pelvic incidence. Pelvic incidence (morphologic parameter) could determine the safe range of pelvis tilt (positional parameter) for an individual and not a group.

  15. Pelvic Incidence: A Predictive Factor for Three-Dimensional Acetabular Orientation—A Preliminary Study

    PubMed Central

    Bollini, Gérard; Legaye, Jean; Tardieu, Christine; Prat-Pradal, Dominique; Chabrol, Brigitte; Jouve, Jean-Luc; Duval-Beaupère, Ginette; Pélissier, Jacques

    2014-01-01

    Acetabular cup orientation (inclination and anteversion) is a fundamental topic in orthopaedics and depends on pelvis tilt (positional parameter) emphasising the notion of a safe range of pelvis tilt. The hypothesis was that pelvic incidence (morphologic parameter) could yield a more accurate and reliable assessment than pelvis tilt. The aim was to find out a predictive equation of acetabular 3D orientation parameters which were determined by pelvic incidence to include in the model. The second aim was to consider the asymmetry between the right and left acetabulae. Twelve pelvic anatomic specimens were measured with an electromagnetic Fastrak system (Polhemus Society) providing 3D position of anatomical landmarks to allow measurement of acetabular and pelvic parameters. Acetabulum and pelvis data were correlated by a Spearman matrix. A robust linear regression analysis provided prediction of acetabulum axes. The orientation of each acetabulum could be predicted by the incidence. The incidence is correlated with the morphology of acetabula. The asymmetry of the acetabular roof was correlated with pelvic incidence. This study allowed analysis of relationships of acetabular orientation and pelvic incidence. Pelvic incidence (morphologic parameter) could determine the safe range of pelvis tilt (positional parameter) for an individual and not a group. PMID:25006461

  16. Computer-aided designed, three dimensional-printed hemipelvic prosthesis for peri-acetabular malignant bone tumour.

    PubMed

    Wang, Baichuan; Hao, Yongqiang; Pu, Feifei; Jiang, Wenbo; Shao, Zengwu

    2018-03-01

    Prosthetic reconstruction may be a promising treatment for peri-acetabular malignant bone tumour; however, it is associated with a high complication rate. Therefore, prosthetic design and approach of prosthetic reconstruction after tumour resection warrant study. We retrospectively analyzed 11 patients with peri-acetabular malignant bone tumours treated by personalized 3D-printed hemipelvic prostheses after en bloc resection between 2015 and 2016. Pre-operative and post-operative pain at rest was assessed according to a 10-cm VAS score. The results of functional improvement were evaluated using the MSTS-93 score at the final follow-up. We also analyzed tumour recurrence, metastases, and complications associated with the reconstruction procedure. All patients were observed for six to 24 months with an average follow-up of 15.5 months. One patient had occasional pain of the involved hip at the final follow-up (VAS, pre vs. post 8 months: 3 vs. 2). The mean MSTS-93 score was 19.2 (range, 13-25). Hip dislocation was detected in two patients, while delayed wound healing occurred in one patient. One patient with mesenchymal chondrosarcoma had a left iliac bone metastasis. Local tumour recurrence was not observed. Reconstruction of bony defect after tumour resection using personalized 3D-printed hemipelvic prostheses can obtain acceptable functional results without severe complications. Based on previous reports and our results, we believe that reconstruction arthroplasty using 3D-printed hemipelvic prostheses will provide a promising alternative for those patients with peri-acetabular malignant bone tumours. Level IV, therapeutic study.

  17. Acetabular rim and surface segmentation for hip surgery planning and dysplasia evaluation

    NASA Astrophysics Data System (ADS)

    Tan, Sovira; Yao, Jianhua; Yao, Lawrence; Summers, Ronald M.; Ward, Michael M.

    2008-03-01

    Knowledge of the acetabular rim and surface can be invaluable for hip surgery planning and dysplasia evaluation. The acetabular rim can also be used as a landmark for registration purposes. At the present time acetabular features are mostly extracted manually at great cost of time and human labor. Using a recent level set algorithm that can evolve on the surface of a 3D object represented by a triangular mesh we automatically extracted rims and surfaces of acetabulae. The level set is guided by curvature features on the mesh. It can segment portions of a surface that are bounded by a line of extremal curvature (ridgeline or crestline). The rim of the acetabulum is such an extremal curvature line. Our material consists of eight hemi-pelvis surfaces. The algorithm is initiated by putting a small circle (level set seed) at the center of the acetabular surface. Because this surface distinctively has the form of a cup we were able to use the Shape Index feature to automatically extract an approximate center. The circle then expands and deforms so as to take the shape of the acetabular rim. The results were visually inspected. Only minor errors were detected. The algorithm also proved to be robust. Seed placement was satisfactory for the eight hemi-pelvis surfaces without changing any parameters. For the level set evolution we were able to use a single set of parameters for seven out of eight surfaces.

  18. Combination acetabular radiofrequency ablation and cementoplasty using a navigational radiofrequency ablation device and ultrahigh viscosity cement: technical note.

    PubMed

    Wallace, Adam N; Huang, Ambrose J; Vaswani, Devin; Chang, Randy O; Jennings, Jack W

    2016-03-01

    Percutaneous radiofrequency ablation and cementoplasty is an alternative palliative therapy for painful metastases involving axial load-bearing bones. This technical report describes the use of a navigational radiofrequency probe to ablate acetabular metastases from an anterior approach followed by instillation of ultrahigh viscosity cement under CT-fluoroscopic guidance. The tumor ablation databases of two institutions were retrospectively reviewed to identify patients who underwent combination acetabular radiofrequency ablation and cementoplasty using the STAR Tumor Ablation and StabiliT Vertebral Augmentation Systems (DFINE; San Jose, CA). Pre-procedure acetabular tumor volume was measured on cross-sectional imaging. Pre- and post-procedure pain scores were measured using the Numeric Rating Scale (10-point scale) and compared. Partial pain improvement was categorically defined as ≥ 2-point pain score reduction. Patients were evaluated for evidence of immediate complications. Electronic medical records were reviewed for evidence of delayed complications. During the study period, 12 patients with acetabular metastases were treated. The median tumor volume was 54.3 mL (range, 28.3-109.8 mL). Pre- and post-procedure pain scores were obtained from 92% (11/12) of the cohort. The median pre-procedure pain score was 8 (range, 3-10). Post-procedure pain scores were obtained 7 days (82%; 9/11), 11 days (9.1%; 1/11) or 21 days (9.1%; 1/11) after treatment. The median post-treatment pain score was 3 (range, 1-8), a statistically significant difference compared with pre-treatment (P = 0.002). Categorically, 73% (8/11) of patients reported partial pain relief after treatment. No immediate symptomatic complications occurred. Three patients (25%; 3/12) were discharged to hospice within 1 week of treatment. No delayed complications occurred in the remaining 75% (9/12) of patients during median clinical follow-up of 62 days (range, 14-178 days). Palliative percutaneous

  19. THE TREATMENT OF IRRADIATION FRACTURE OF THE FEMORAL NECK

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leabhart, J.W.; Bonfiglio, M.

    1961-10-01

    Treatment of 44 patients with 56 postirradiation fractures of the femoral neck is reported. Of 2612 patients who received pelvic irradiation for carcinoma of the uterine cervix, 40 developed fractures of the femoral neck, an incidence of 1.5%. Sixteen of the 40 patients had bilateral fractures. The average age of the patients was 58.5 yr at the time of irradiation. The average irradiation dose was approximates 3600 r (parametrial dose), the largest dose being 4235 r. The average interval from irradiation to the onset of pain in the hip was 36.6 months (3 to 240 months) and from the onsetmore » of pain to diagnosis, 3 months. Forty-six surgical procedures were performed: 36 as primary treatment and 9 because of failure or complications of the first procedure. The average follow-up time of these patients was 6.9 yr. The presenting complaint was usually spontaneous onset of pain in the groin and medial portion of the thigh. Initially the physical examination often revealed only restriction of internal rotation of the affected hip, and the roentgenograms appeared normal in some instances. Subsequently, a change in bone density was noted at the inferior aspect of the femoral neck, denoting an adduction type of fracture. The displaced fractures resembled the traumatic adduction fractures of the femoral neck seen in patients who had not received irradiation. Acetabular changes were also noted, characterized by marked osteoporosis and occasionally fracture of the acetabulum. Seven methods of primary therapy were used to treat these patients: no treatment, nonsurgical measures (crutches or bedrest), internal fixation, bone- grafting (with and without additional fixation), osteotomy, arthroplasty, and the insertion of a prosthesis. Early in situ internal fixation or internal fixation with bone grafts was the procedure of choice in fractures of the femorai neck secondary to irradiation. Reconstructive procedures, such as cup arthroplasty or insertion of a prosthesis, were

  20. The obturator oblique and iliac oblique/outlet views predict most accurately the adequate position of an anterior column acetabular screw.

    PubMed

    Guimarães, João Antonio Matheus; Martin, Murphy P; da Silva, Flávio Ribeiro; Duarte, Maria Eugenia Leite; Cavalcanti, Amanda Dos Santos; Machado, Jamila Alessandra Perini; Mauffrey, Cyril; Rojas, David

    2018-06-08

    Percutaneous fixation of the acetabulum is a treatment option for select acetabular fractures. Intra-operative fluoroscopy is required, and despite various described imaging strategies, it is debatable as to which combination of fluoroscopic views provides the most accurate and reliable assessment of screw position. Using five synthetic pelvic models, an experimental setup was created in which the anterior acetabular columns were instrumented with screws in five distinct trajectories. Five fluoroscopic images were obtained of each model (Pelvic Inlet, Obturator Oblique, Iliac Oblique, Obturator Oblique/Outlet, and Iliac Oblique/Outlet). The images were presented to 32 pelvic and acetabular orthopaedic surgeons, who were asked to draw two conclusions regarding screw position: (1) whether the screw was intra-articular and (2) whether the screw was intraosseous in its distal course through the bony corridor. In the assessment of screw position relative to the hip joint, accuracy of surgeon's response ranged from 52% (iliac oblique/outlet) to 88% (obturator oblique), with surgeon confidence in the interpretation ranging from 60% (pelvic inlet) to 93% (obturator oblique) (P < 0.0001). In the assessment of intraosseous position of the screw, accuracy of surgeon's response ranged from 40% (obturator oblique/outlet) to 79% (iliac oblique/outlet), with surgeon confidence in the interpretation ranging from 66% (iliac oblique) to 88% (pelvic inlet) (P < 0.0001). The obturator oblique and obturator oblique/outlet views afforded the most accurate and reliable assessment of penetration into the hip joint, and intraosseous position of the screw was most accurately assessed with pelvic inlet and iliac oblique/outlet views. Clinical Question.

  1. The outcome of unstable proximal femoral fracture treated with reverse LISS plates.

    PubMed

    Lin, Shih-Jie; Huang, Kuo-Chin; Chuang, Po-Yao; Lee, Chien-Yin; Huang, Tsan-Wen; Lee, Mel S; Hsu, Robert Wen-Wei

    2016-10-01

    The Russel-Taylor type 2B fractures compromised the trochanteric region and medial buttress of proximal femur. This fracture pattern limits the choice of implants and raises the risk of adverse outcomes. We aimed to (i) determine the outcome of Russel-Taylor type 2B fractures treated using reverse less invasive stabilization system plates (LISS-DF) and to (ii) learn what factors affected outcomes after osteosynthesis with reverse LISS plates. A retrospective study SETTING: The study was conducted at a Level III trauma center in Taiwan. Twenty-five consecutive patients presenting with a Russel-Taylor type 2B fracture were enrolled. All cases were treated with reverse LISS plates. A Modified Radiographic Union Scale for Femur (RUSF), Radiographic parameters, functional scores, and complications were assessed. Union occurred in 21 cases at an average of 18.8 weeks. The average immediate postoperative neck-shaft angle was 130° (range: 122-135°) compared with 139° (range: 135-141°, p=0.05) on the contralateral side. Two cases had complications of proximal screws cutting out and two cases had broken implants. Finally, all 4 cases required repeated surgeries (16%). Malunion occurred in 4 patients and early mechanical failure (proximal screws cut out) occurred in 2. There was a significant difference in the purchase index of the proximal screws between cases with redisplacement and those without (26.4mm and 98.6mm, p=0.01). The use of reverse LISS plate appeared to be an alternative procedure for the specific pattern in the present study. We recommend using this reverse locking plate to treat unstable proximal femoral fractures with meticulous techniques of placing plates. Adequate purchase of the proximal locking screws might decrease the risks of complications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. [Intramedullary nailing combined with cannulated screw in treating femoral condyles fractures].

    PubMed

    Shen, Guo-Qing; Zhang, Hao; Long, Da-Fu; Li, Zheng-Wen; Tan, Ying-Dong

    2017-07-25

    To observe the clinical effects of retrograde intramedullary nailing and cannulated screws in the treatment of femoral condylar fracture. From June 2009 to June 2015, 13 patients with femoral condyles fracture were treated by retrograde intramedullary nailing and cannulated screws including 6 males and 7 females with an average age of 46.1 years old ranging from 16 to 76 years old. There were 10 cases of closed fractures, 3 cases of open fraetures. According to AO classification criteriam, 4 cases were type C1, 7 cases were type C2, 2 cases were type C3. Postoperative reduction of fracture and the knee joint function recovery were observed. All patients were followed up for 12 to 36 months with a mean of 24 months. X-ray examination showed that the union time of fracture was 18 to 24 weeks, 21 weeks on average. There were no cases of loosening, breakage of internal fixators and re-fracture. Hospital for Special Surgery(HSS) knee score was 90.07±4.99 at 1 year after the operation. The clinical efficacy for retrograde intramedullary nailing and cannulated screw for the treatment of femoral condyles fracture was excellent. It can improve the anatomical reattachment rate and reduce the complications and promote the knee functional recovery.

  3. Complications of Elastic Stable Intramedullary Nailing for treating paediatric long bone fractures

    PubMed Central

    Nisar, Aamer; Bhosale, Abhijit; Madan, Sanjeev S.; Flowers, Mark J.; Fernandes, James A.; Jones, Stanley

    2013-01-01

    This study reports the complications observed in children with long bone fractures treated using Elastic Stable Intramedullary Nailing (ESIN). One hundred and sixty-four (n = 164) fractures in 160 patients under the age of 16 years formed the basis of our review. This included 108 boys and 52 girls with the median age of 11 years and median follow up of 7.5 months. The analysis included fractures of the radius/ulna, humerus, femur and tibia. All pathological fractures were excluded. In this series 54 patients (34%) had complications however majority of these were minor complications with irritation due to prominent nail ends being the commonest complication. No long-term sequelae were encountered in our patients. PMID:24403743

  4. Short-term Results of Robinson Type 2B2 Clavicular Fractures Treated Conservatively or Surgically.

    PubMed

    Malkoc, Melih; Korkmaz, Ozgur; Bayram, Erhan; Ormeci, Tugrul; Isyar, Mehmet; Yilmaz, Murat; Seker, Ali

    2016-01-01

    The most frequently treated injuries, representing approximately 82% of all clavicular fractures, involve the midshaft clavicle. Historically, most acute displaced midshaft clavicular fractures were treated nonsurgically. However, the outcomes of nonsurgical treatment have recently been thought to be not as good as expected in the past, and the trend is to treat these fractures surgically. The goal of this study was to evaluate the short-term clinical outcomes of Robinson type 2B2 clavicular fractures treated conservatively vs with locked plate fixation. Among 59 patients included in the study, 30 patients (mean age, 45±13.7 years; range, 30-62 years) treated conservatively were designated as group A, and 29 patients (mean age, 38.8±11.1 years; range, 20-60 years) treated with locked plate fixation were designated as group B. All patients were evaluated using Oxford and Constant scoring systems at final follow-up. Mean follow-up was 18 months (range, 12-24 months). In group A, mean Constant score was 70.5±15.1 (range, 98-43) and mean Oxford score was 46.6±1.3 (range, 49-44) at final follow-up. In group B, mean Constant score was 89.2±8 (range, 100-77) and mean Oxford score was 46.5±1.2 (range, 48-44) at final follow-up. Callus was detected radiographically in both groups at 6-week follow-up. Patients in groups A and B started active range-of-motion exercises at weeks 6 and 3 after treatment, respectively. Locked plate fixation of Robinson type 2B2 clavicular fractures can be the first treatment option because of good clinical results, low complication rates, and good cosmesis. Copyright 2016, SLACK Incorporated.

  5. Outcome Determining Factors for displaced Intra-articular Calcaneal Fractures treated operatively

    PubMed Central

    Chan, KL; Idham, HM; Izani, IM; Nahulan, T

    2015-01-01

    Introduction: Calcaneal fractures are caused by high energy trauma and mostly are intra-articular fractures. Nondisplaced intra-articular calcaneal fracture (IACF) can be treated non-operatively. However, displaced intra-articular need to be reduced and fixed anatomically to facilitate early ankle rehabilitation and minimize functional impairment. This study was done to find out the outcome of the IACF patients who underwent operative treatment. Methods: 62 patients with IACF were selected in this study and had been followed up from June 2009 to May 2013. They were placed into two groups; the operative treated and non-operative treated groups. Bilateral ankle lateral view plain radiographs were taken for comparison of the Bohler and Gissane angles. Both groups of patients were assessed by the Maryland Foot Score (MFS) and the SF-36v2 general health survey questionnaire. The ability of the patients to perform activity of daily living (ADL) and /or return to work (RTW) was assessed as well. Results: The operative treatment group of displaced IACF patients achieved no significant better scores in the mean MFS and SF-36v2 mean scores as compared to non operated cases. There was no difference in RTW between the 2 groups, but earlier ADL was recorded in the operated group. However, this study had found 5 associated factors which causes major effect to the patients’ outcome to treatment. Conclusions: The patient’s compliance with post-operative rehabilitation regimen were found to be significantly related with the outcomes. PMID:28611903

  6. Arthroscopic treatment of femoral nerve paresthesia caused by an acetabular paralabral cyst.

    PubMed

    Kanauchi, Taira; Suganuma, Jun; Mochizuki, Ryuta; Uchikawa, Shinichi

    2014-05-01

    This report describes a rare case of femoral nerve paresthesia caused by an acetabular paralabral cyst of the hip joint. A 68-year-old woman presented with a 6-month history of right hip pain and paresthesia along the anterior thigh and radiating down to the anterior aspect of the knee. Radiography showed osteoarthritis with a narrowed joint space in the right hip joint. Magnetic resonance imaging showed a cyst with low T1- and high T2-weighted signal intensity arising from a labral tear at the anterior aspect of the acetabulum. The cyst was connected to the joint space and displaced the femoral nerve to the anteromedial side. The lesion was diagnosed as an acetabular paralabral cyst causing femoral neuropathy. Because the main symptom was femoral nerve paresthesia and the patient desired a less invasive procedure, arthroscopic labral repair was performed to stop synovial fluid flow to the paralabral cyst that was causing the femoral nerve paresthesia. After surgery, the cyst and femoral nerve paresthesia disappeared. At the 18-month follow-up, the patient had no recurrence. There have been several reports of neurovascular compression caused by the cyst around the hip joint. To the authors' knowledge, only 3 cases of acetabular paralabral cysts causing sciatica have been reported. The current patient appears to represent a rare case of an acetabular paralabral cyst causing femoral nerve paresthesia. The authors suggest that arthroscopic labral repair for an acetabular paralabral cyst causing neuropathy can be an option for patients who desire a less invasive procedure. Copyright 2014, SLACK Incorporated.

  7. The effect of acetabular cup size on the short-term stability of revision hip arthroplasty: a finite element investigation.

    PubMed

    Phillips, A T M; Pankaj; Usmani, A S; Howie, C R

    2004-01-01

    The study uses idealized two-dimensional finite element models to examine the behaviour of the acetabular construct following revision hip arthroplasty, carried out using the Slooff-Ling impaction grafting technique. The behaviour of bone graft was considered in detail, with non-linear elasticity and non-associated plasticity being adopted. Load was applied to the acetabular construct through a femoral head using smooth sliding surfaces. In particular, four models were subjected to two idealized cyclic load cases to investigate the effect of acetabular cup size on the short-term stability of the acetabular construct. The study suggests that benefits may be gained by using the largest practical size of acetabular cup.

  8. High-precision measurements of cementless acetabular components using model-based RSA: an experimental study.

    PubMed

    Baad-Hansen, Thomas; Kold, Søren; Kaptein, Bart L; Søballe, Kjeld

    2007-08-01

    In RSA, tantalum markers attached to metal-backed acetabular cups are often difficult to detect on stereo radiographs due to the high density of the metal shell. This results in occlusion of the prosthesis markers and may lead to inconclusive migration results. Within the last few years, new software systems have been developed to solve this problem. We compared the precision of 3 RSA systems in migration analysis of the acetabular component. A hemispherical and a non-hemispherical acetabular component were mounted in a phantom. Both acetabular components underwent migration analyses with 3 different RSA systems: conventional RSA using tantalum markers, an RSA system using a hemispherical cup algorithm, and a novel model-based RSA system. We found narrow confidence intervals, indicating high precision of the conventional marker system and model-based RSA with regard to migration and rotation. The confidence intervals of conventional RSA and model-based RSA were narrower than those of the hemispherical cup algorithm-based system regarding cup migration and rotation. The model-based RSA software combines the precision of the conventional RSA software with the convenience of the hemispherical cup algorithm-based system. Based on our findings, we believe that these new tools offer an improvement in the measurement of acetabular component migration.

  9. Anterior subcutaneous internal fixation for treatment of unstable pelvic fractures

    PubMed Central

    2014-01-01

    Background Fractures of the pelvic ring including disruption of the posterior elements in high-energy trauma have both high morbidity and mortality rates. For some injury pattern part of the initial resuscitation includes either external fixation or plate fixation to close the pelvic ring and decrease blood loss. In certain situations – especially when associated with abdominal trauma and the need to perform laparotomies – both techniques may put the patient at risk of either pintract or deep plate infections. We describe an operative approach to percutaneously close and stabilize the pelvic ring using spinal implants as an internal fixator and report the results in a small series of patients treated with this technique during the resuscitation phase. Findings Four patients were treated by subcutaneous placement of an internal fixator. Screw fixation was carried out by minimally invasive placement of two supra-acetabular iliac screws. Afterwards, a subcutaneous transfixation rod was inserted and attached to the screws after reduction of the pelvic ring. All patients were allowed to fully weight-bear. No losses of reduction or deep infections occurred. Fracture healing was uneventful in all cases. Conclusion Minimally invasive fixation is an alternative technique to stabilize the pelvic ring. The clinical results illustrate that this technique is able to achieve good results in terms of maintenance of reduction the pelvic ring. Also, abdominal surgeries no longer put the patient at risk of infected pins or plates. PMID:24606833

  10. Impact of attention deficit hyperactivity disorder therapy on fracture risk in children treated in German pediatric practices.

    PubMed

    Jacob, L; Kostev, K

    2017-04-01

    Two thousand eight hundred ninety-four children and adolescents treated by 243 pediatricians were analyzed. Patients receiving attention deficit hyperactivity disorder (ADHD) medications were at a lower risk of fractures than patients without ADHD medications. The strongest impact was in the age group of 6-9 years. Finally, there was a significant association between therapy duration and fracture risk. The aim of this study was to analyze the impact of ADHD therapy on fracture risk in children treated by German pediatricians. Children and adolescents initially diagnosed with ADHD and fractures between 2010 and 2015 were identified by 243 pediatricians. In this nested case-control study, each ADHD case with a fracture was matched (1:1) to an ADHD control without a fracture for age, gender, index year, and physician. In total, 2894 individuals were available for analysis. The main outcome of the study was the risk of fracture as a function of ADHD therapy. Multivariate logistic regression models were created to determine the effect of ADHD therapy on the risk of fracture in the entire population and in three age-specific subgroups. Patients receiving ADHD medications were at a lower risk of fracture than patients without ADHD medications (OR = 0.61). The impact of ADHD therapy on the risk of fracture was stronger in the age group of 6-9 years (OR = 0.41) than in the age groups of 10-13 years (OR = 0.68) and 14-17 years (OR = 0.74). Finally, a significant correlation was found between therapy duration and fracture risk (OR = 0.71 per month). ADHD therapy was associated with a decrease in the risk of fracture in children and adolescents treated by German pediatricians.

  11. Progression of a fracture site impaction as a prognostic indicator of impacted femoral neck fracture treated with multiple pinning.

    PubMed

    Yoon, Pil Whan; Shin, Young Ho; Yoo, Jeong Joon; Yoon, Kang Sup; Kim, Hee Joong

    2012-03-01

    We evaluated the clinical and radiologic results of impacted femoral neck fractures treated with multiple pinning and determined the influence of the progression of impaction at the fracture site on clinical outcome. There were 34 patients with a mean age of 65.5 years. The mean follow-up period was 3.4 years. Progression of fracture site impaction was measured using an articulo-trochanteric distance index and the percentage decrease in the articulo-trochanteric distance index between follow-up intervals. The failure of treatment was clarified as non-union and avascular necrosis. Other characteristics of the patients, including mean waiting time for surgery, preoperative Singh index score, and body mass index, were also measured to evaluate the influence on the clinical outcome of surgery. There were 6 fractures which were not treated successfully (3 non-union, 8.8% and 3 avascular necrosis, 8.8%). The mean percentage decrease of the articulo-trochanteric distance index within the first 6 weeks after surgery was 4.5% in the successful group and 25.1% in the failure group (p < 0.001). There was also a significant mean percentage decrease in the articulo-trochanteric distance index between 6 weeks and 3 months (p < 0.001). Primary stabilization with Knowles pins for impacted femoral neck fractures had a reasonable clinical outcome with low morbidity. Despite a significant difference of a mean percentage decrease in the articulo-trochanteric distance index between the successful group and the failure group, we could not verify it as a risk factor for failure of treatment because the odds ratio was not statistically significant.

  12. Revision rates and cumulative financial burden in patients treated with hemiarthroplasty compared to cannulated screws after femoral neck fractures.

    PubMed

    Shields, Edward; Kates, Stephen L

    2014-12-01

    This study compares re-operation rates and financial burden following the treatment of femoral neck fractures treated with hemiarthroplasty compared to non-displaced femoral neck fractures treated with cannulated screws. Data was retrospectively analyzed from a prospective database at a university hospital setting on patients undergoing hemiarthroplasty after femoral neck fractures and those with non-displaced femoral neck fractures treated with cannulated screws over a 7-year period. Re-operation rates were determined and financial data was analyzed. Charges refer to amounts billed by the hospital to insurance carriers, while costs refer to financial burden carried by the hospital during treatment. There were 491 femoral neck fractures (475 patients) that underwent hemiarthroplasty (HA) and 120 non-displaced fractures (119 patients) treated with cannulated screw (CannS) fixation. Both groups had similar age, sex, Charlson co-morbidity scores, pre-operative Parker mobility scores, and 12-month mortality. There were 29 (5.9 %) reoperations in the HA group and 16 (13.3 %) in the CannS group (P = 0.007). The majority of re-operations occurred within 12 months for both groups [21/29 (72 %) HA group; 15/16 (94 %) CannS group; P = 0.13]. Average hospital charges per patient for the index procedure were higher in the HA group ($17,880 ± 745) compared to the CannS group ($14,104 ± 5,047; P < 0.001). After accounting for additional procedures related to their initial surgical fixation, average hospital charges and costs remained higher in the HA group. Patients treated with hemiarthroplasty for femoral neck fractures have lower re-operation rates than patients treated with cannulated screws for non-displaced femoral neck fractures, with 80 % of re-operations occurring in the first 12 months. Hospital charges and costs to the hospital for treating patients undergoing hemiarthroplasty were higher than patients treated with cannulated screws for the index procedure alone

  13. Is labral hypotrophy correlated with increased acetabular depth?

    PubMed Central

    Toft, Felix; Anliker, Elmar; Beck, Martin

    2015-01-01

    Labral hypertrophy is a distinct feature in hip dysplasia. Occasionally, very small, hypotrophic labra are observed. However, there is no literature concerning this pathology. We investigated if the size of the labrum correlated with any radiologic parameters reflecting the amount of acetabular coverage. It was hypothezised that there is a negative correlation between labrum size and acetabular coverage. Labra were categorized into three groups depending on the relation between length of the articular sided surface and height of bony attachment. Labra with a height:length ratio of 2 were classified as hypotrophic, with a height:length ratio of 1 as normal and with a ratio of 0.5 as hypertrophic. Labral cross-sectional areas (CSA) were measured on radial magnetic resonance imaging-arthrography slices using the measuring tool of the PACS system of 20 hips with hypotrophic labra (group 1), 20 hips with normal labral appearance (group 2) and 10 hips with hypertrophic labra (group 3). These values were then analyzed against following parameters: neck-shaft-angle (NSA), lateral center-edge angle (LCE), acetabular index (AI), femoral extrusion index (FEI) and acetabular retroversion index (ARI). Analyses of variance were used to determine differences in mean values between the three groups. Mean labral CSA differed significantly between all groups (group 1: 12.1 ± 2.9 mm2; group 2: 25.2 ± 6.2 mm2; group 3: 41.1 ± 12.3 mm2; P < 0.001). NSA, LCE, AI and FEI all showed a significant difference between group 3 and 1 or 2. The ARI showed no difference between groups. Stepwise linear regression analyses showed a significant correlation between LCE angle and labral CSA with a corrected R2-value of 0.301. Labral CSA correlates with the LCE. No statistically significant difference between groups 1 and 2 concerning the LCE, AI or FEI could be identified. Nevertheless, group 1 had the highest mean coverage of all groups, hips with hypertrophic labra

  14. The prevalence of acetabular anomalies associated with pistol-grip-deformity in osteoarthritic hips.

    PubMed

    Ipach, I; Mittag, F; Walter, C; Syha, R; Wolf, P; Kluba, T

    2013-02-01

    Acetabular retroversion, excessive acetabular coverage and abnormal head-neck-junction with a so-called "pistol-grip-deformity" were added to the classical description of hip dysplasia to describe pathological hip morphology. The aim of the current study was the detection of pathological acetabular geometry in patients with an abnormal head-neck-junction. Femoroacetabular impingement and hip dysplasia features are frequent in patients with end-stage osteoarthritis before 60 years of age. We analysed our data bank retrospectively for all patients who received a Total Hip Arthroplasty (THA) due to end-stage osteoarthritis before the age of 60 years. The pelvic-views and the Dunn-view of these patients were screened for an abnormal head-neck-junction by measuring the head-ratio and the alpha-angle. An orthopaedic surgeon and a radiologist did this independently. These radiographies were measured for signs of acetabular dysplasia, excessive acetabular coverage and crossing sign. A consecutive series of 135 total hip arthroplasties were performed in patients aged less or equal to 60 years because of end-stage osteoarthritis. From these, 81 patients were classified as having an abnormal head-neck-junction. The mean head-ratio in these 81 patients was 1.52±0.35, the mean alpha-angle was 62.5°±9.3°. The mean CE-angle of these 81 patients was 35.8°±10.4°, the mean CA-angle was 36.7°±5.7°, the mean depth-width ratio was 49.1±10, the mean extrusion index was 19.1±9.2 and the mean CCD-angle was 131.7°±7.3°. Of these 81hips, 14 had isolated pistol-grip-deformity, while 11 hips had associated dysplasia, 38 had excessive acetabular coverage, and 14 had crossing sign. In addition, a crossing sign was identified in four of the 11 dysplastic hips and 19 of the 38 of the hips having excessive acetabular coverage. There was no statistically significant difference in regard to the age between the four groups (P=0.087). In contrast, the hips that had excessive acetabular

  15. Fracture Strength of Endodontically Treated Teeth with Different Access Cavity Designs.

    PubMed

    Plotino, Gianluca; Grande, Nicola Maria; Isufi, Almira; Ioppolo, Pietro; Pedullà, Eugenio; Bedini, Rossella; Gambarini, Gianluca; Testarelli, Luca

    2017-06-01

    The purpose of this study was to compare in vitro the fracture strength of root-filled and restored teeth with traditional endodontic cavity (TEC), conservative endodontic cavity (CEC), or ultraconservative "ninja" endodontic cavity (NEC) access. Extracted human intact maxillary and mandibular premolars and molars were selected and assigned to control (intact teeth), TEC, CEC, or NEC groups (n = 10/group/type). Teeth in the TEC group were prepared following the principles of traditional endodontic cavities. Minimal CECs and NECs were plotted on cone-beam computed tomographic images. Then, teeth were endodontically treated and restored. The 160 specimens were then loaded to fracture in a mechanical material testing machine (LR30 K; Lloyd Instruments Ltd, Fareham, UK). The maximum load at fracture and fracture pattern (restorable or unrestorable) were recorded. Fracture loads were compared statistically, and the data were examined with analysis of variance and the Student-Newman-Keuls test for multiple comparisons. The mean load at fracture for TEC was significantly lower than the one for the CEC, NEC, and control groups for all types of teeth (P < .05), whereas no difference was observed among CEC, NEC, and intact teeth (P > .05). Unrestorable fractures were significantly more frequent in the TEC, CEC, and NEC groups than in the control group in each tooth type (P < .05). Teeth with TEC access showed lower fracture strength than the ones prepared with CEC or NEC. Ultraconservative "ninja" endodontic cavity access did not increase the fracture strength of teeth compared with the ones prepared with CEC. Intact teeth showed more restorable fractures than all the prepared ones. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. Cemented total hip replacement cable debris and acetabular construct durability.

    PubMed

    Altenburg, Aaron J; Callaghan, John J; Yehyawi, Tameem M; Pedersen, Douglas R; Liu, Steve S; Leinen, Jessica A; Dahl, Kevin A; Goetz, Devon D; Brown, Thomas D; Johnston, Richard C

    2009-07-01

    Third-body wear can adversely affect the outcome of total hip arthroplasty by causing increased polyethylene wear, osteolysis, and component loosening. We hypothesized that there would be greater generation and migration of metal debris to the bearing surfaces in hips in which cobalt-chromium cables were used to reattach the osteotomized greater trochanter when compared with hips in which stainless steel wires were used. Between June 1981 and December 1983, 196 consecutive total hip arthroplasties were performed with use of an Iowa stem and a titanium-backed cemented acetabular component, with cobalt-chromium cable trochanteric reattachment. After nineteen to twenty years of follow-up, the patients were evaluated with regard to the depth of head penetration into the polyethylene (as a surrogate for wear), osteolysis, loosening, and the need for revision. The results were compared with those for a series of 304 total hip arthroplasties that were performed by the same surgeon from January 1984 to December 1985 with use of the same components and the same surgical technique, but with stainless steel wire trochanteric reattachment. The two groups had a comparable nineteen to twenty-year follow-up. All living patients (fifty-nine hips in the cable group and ninety-two hips in the wire group) had minimum ten-year follow-up radiographs. The polyethylene wear rate was 0.101 mm/yr for the cable group and 0.082 mm/yr for the wire group (p = 0.039). For the living patients, the rate of revision of the acetabular component because of aseptic loosening was 37.3% (twenty-two hips) for the cable group and 20.7% (nineteen hips) for the wire group (p = 0.025). The rate of acetabular osteolysis was 44% (twenty-six hips) for the cable group and 26% (twenty-four hips) for the wire group (p = 0.022). Kaplan-Meier analysis with revision of the acetabular component because of aseptic loosening as the end point demonstrated survival rates of 73.7% +/- 9% and 83% +/- 7% for the cable and

  17. Optimal acetabular component orientation estimated using edge-loading and impingement risk in patients with metal-on-metal hip resurfacing arthroplasty.

    PubMed

    Mellon, Stephen J; Grammatopoulos, George; Andersen, Michael S; Pandit, Hemant G; Gill, Harinderjit S; Murray, David W

    2015-01-21

    Edge-loading in patients with metal-on-metal resurfaced hips can cause high serum metal ion levels, the development of soft-tissue reactions local to the joint called pseudotumours and ultimately, failure of the implant. Primary edge-loading is where contact between the femoral and acetabular components occurs at the edge/rim of the acetabular component whereas impingement of the femoral neck on the acetabular component's edge causes secondary or contrecoup edge-loading. Although the relationship between the orientation of the acetabular component and primary edge-loading has been identified, the contribution of acetabular component orientation to impingement and secondary edge-loading is less clear. Our aim was to estimate the optimal acetabular component orientation for 16 metal-on-metal hip resurfacing arthroplasty (MoMHRA) subjects with known serum metal ion levels. Data from motion analysis, subject-specific musculoskeletal modelling and Computed Tomography (CT) measurements were used to calculate the dynamic contact patch to rim (CPR) distance and impingement risk for 3416 different acetabular component orientations during gait, sit-to-stand, stair descent and static standing. For each subject, safe zones free from impingement and edge-loading (CPR <10%) were defined and, consequently, an optimal acetabular component orientation was determined (mean inclination 39.7° (SD 6.6°) mean anteversion 14.9° (SD 9.0°)). The results of this study suggest that the optimal acetabular component orientation can be determined from a patient's motion and anatomy. However, 'safe' zones of acetabular component orientation associated with reduced risk of dislocation and pseudotumour are also associated with a reduced risk of edge-loading and impingement. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Endoscopic resection of acetabular screw tip to decompress sciatic nerve following total hip arthroplasty.

    PubMed

    Yoon, Sun-Jung; Park, Myung-Sik; Matsuda, Dean K; Choi, Yun Ho

    2018-06-04

    Sciatic nerve injuries following total hip arthroplasty are disabling complications. Although degrees of injury are variable from neuropraxia to neurotmesis, mechanical irritation of sciatic nerve might be occurred by protruding hardware. This case shows endoscopic decompression for protruded acetabular screw irritating sciatic nerve, the techniques described herein may permit broader arthroscopic/endoscopic applications for management of complications after reconstructive hip surgery. An 80-year-old man complained of severe pain and paresthesias following acetabular component revision surgery. Physical findings included right buttock pain with radiating pain to lower extremity. Radiographs and computed tomography imaging showed that the sharp end of protruded screw invaded greater sciatic foramen anterior to posterior and distal to proximal direction at sciatic notch level. A protruding tip of the acetabular screw at the sciatic notch was decompressed by use of techniques gained from experience performing endoscopic sciatic nerve decompression. The pre-operative pain and paresthesias resolved post-operatively after recovering from anesthesia. This case report describes the first documented endoscopic resection of the tip of the acetabular screw irritating sciatic nerve after total hip arthroplasty. If endoscopic resection of an offending acetabular screw can be performed in a safe and minimally invasive manner, one can envision a future expansion of the role of hip arthroscopic surgery in several complications management after total hip arthroplasty.

  19. Fracture resistance of endodontically treated teeth restored with a bulkfill flowable material and a resin composite

    PubMed Central

    Isufi, Almira; Plotino, Gianluca; Grande, Nicola Maria; Ioppolo, Pietro; Testarelli, Luca; Bedini, Rossella; Al-Sudani, Dina; Gambarini, Gianluca

    2016-01-01

    Summary Aim To determine and compare the fracture resistance of endodontically treated teeth restored with a bulk fill flowable material (SDR) and a traditional resin composite. Methods Thirty maxillary and 30 mandibular first molars were selected based on similar dimensions. After cleaning, shaping and filling of the root canals and adhesive procedures, specimens were assigned to 3 subgroups for each tooth type (n=10): Group A: control group, including intact teeth; Group B: access cavities were restored with a traditional resin composite (EsthetX; Dentsply-Italy, Rome, Italy); Group C: access cavities were restored with a bulk fill flowable composite (SDR; Dentsply-Italy), except 1.5 mm layer of the occlusal surface that was restored with the same resin composite as Group B. The specimens were subjected to compressive force in a material static-testing machine until fracture occurred, the maximum fracture load of the specimens was measured (N) and the type of fracture was recorded as favorable or unfavorable. Data were statistically analyzed with one-way analysis of variance (ANOVA) and Bonferroni tests (P<0.05). Results No statistically significant differences were found among groups (P<0.05). Fracture resistance of endodontically treated teeth restored with a traditional resin composite and with a bulk fill flowable composite (SDR) was similar in both maxillary and mandibular molars and showed no significant decrease in fracture resistance compared to intact specimens. Conclusions No significant difference was observed in the mechanical fracture resistance of endodontically treated molars restored with traditional resin composite restorations compared to bulk fill flowable composite restorations. PMID:27486505

  20. Fracture resistance of endodontically treated teeth restored with a bulkfill flowable material and a resin composite.

    PubMed

    Isufi, Almira; Plotino, Gianluca; Grande, Nicola Maria; Ioppolo, Pietro; Testarelli, Luca; Bedini, Rossella; Al-Sudani, Dina; Gambarini, Gianluca

    2016-01-01

    To determine and compare the fracture resistance of endodontically treated teeth restored with a bulk fill flowable material (SDR) and a traditional resin composite. Thirty maxillary and 30 mandibular first molars were selected based on similar dimensions. After cleaning, shaping and filling of the root canals and adhesive procedures, specimens were assigned to 3 subgroups for each tooth type (n=10): Group A: control group, including intact teeth; Group B: access cavities were restored with a traditional resin composite (EsthetX; Dentsply-Italy, Rome, Italy); Group C: access cavities were restored with a bulk fill flowable composite (SDR; Dentsply-Italy), except 1.5 mm layer of the occlusal surface that was restored with the same resin composite as Group B. The specimens were subjected to compressive force in a material static-testing machine until fracture occurred, the maximum fracture load of the specimens was measured (N) and the type of fracture was recorded as favorable or unfavorable. Data were statistically analyzed with one-way analysis of variance (ANOVA) and Bonferroni tests (P<0.05). No statistically significant differences were found among groups (P<0.05). Fracture resistance of endodontically treated teeth restored with a traditional resin composite and with a bulk fill flowable composite (SDR) was similar in both maxillary and mandibular molars and showed no significant decrease in fracture resistance compared to intact specimens. No significant difference was observed in the mechanical fracture resistance of endodontically treated molars restored with traditional resin composite restorations compared to bulk fill flowable composite restorations.

  1. The Morscher Press-Fit Acetabular Component: An Independent Long-Term Review at 18-22 Years.

    PubMed

    Gwynne-Jones, David P; Lash, Heath W R; James, Andrew W; Iosua, Ella E; Matheson, John A

    2017-08-01

    There are relatively few 20-year results of uncemented acetabular components, and most of these are modular designs. This study reports the 20-year results of a monoblock press-fit acetabular component. A total of 122 total hip arthroplasties (111 patients) using the Morscher cup were reviewed at a mean of 19.7 years. The average age at implantation was 57.3 years (range, 36-74 years), and 81 (66%) were men. Twenty-two patients (25 hips) had died. Seven hips were revised, including 5 acetabular revisions. Six patients (6 hips) declined to participate but were known not to have been revised. The mean Oxford hip score was 41.1 (range, 22-48), and the mean reduced Western Ontario and McMaster Universities Osteoarthritis Index score was 5.7/48 (range, 0-24). Eccentric wear was seen in 13 (15.7%) and major osteolysis in 14 (17%) of 82 surviving hips with radiographs. The all-cause revision rate was 0.32 per 100 observed component years (95% confidence interval [CI], 0.13-0.66). The 20-year Kaplan-Meier survival was 93.4% (CI, 86.6-96.8) for all-cause revisions, 95.5% (CI, 89.4-98.1) for any acetabular revision, and 97.1% (CI, 91.2-99.1) for acetabular aseptic loosening, wear, or osteolysis. The Morscher acetabular component has continued to perform well at 20 years despite using conventional polyethylene with results that match or surpass other cementless acetabulae. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Progression of a Fracture Site Impaction as a Prognostic Indicator of Impacted Femoral Neck Fracture Treated with Multiple Pinning

    PubMed Central

    Yoon, Pil Whan; Shin, Young Ho; Yoo, Jeong Joon; Yoon, Kang Sup

    2012-01-01

    Background We evaluated the clinical and radiologic results of impacted femoral neck fractures treated with multiple pinning and determined the influence of the progression of impaction at the fracture site on clinical outcome. Methods There were 34 patients with a mean age of 65.5 years. The mean follow-up period was 3.4 years. Progression of fracture site impaction was measured using an articulo-trochanteric distance index and the percentage decrease in the articulo-trochanteric distance index between follow-up intervals. The failure of treatment was clarified as non-union and avascular necrosis. Other characteristics of the patients, including mean waiting time for surgery, preoperative Singh index score, and body mass index, were also measured to evaluate the influence on the clinical outcome of surgery. Results There were 6 fractures which were not treated successfully (3 non-union, 8.8% and 3 avascular necrosis, 8.8%). The mean percentage decrease of the articulo-trochanteric distance index within the first 6 weeks after surgery was 4.5% in the successful group and 25.1% in the failure group (p < 0.001). There was also a significant mean percentage decrease in the articulo-trochanteric distance index between 6 weeks and 3 months (p < 0.001). Conclusions Primary stabilization with Knowles pins for impacted femoral neck fractures had a reasonable clinical outcome with low morbidity. Despite a significant difference of a mean percentage decrease in the articulo-trochanteric distance index between the successful group and the failure group, we could not verify it as a risk factor for failure of treatment because the odds ratio was not statistically significant. PMID:22379557

  3. Fractures and Osteomalacia in a Patient Treated With Frequent Home Hemodialysis.

    PubMed

    Hanudel, Mark R; Froch, Larry; Gales, Barbara; Jüppner, Harald; Salusky, Isidro B

    2017-09-01

    Bone deformities and fractures are common consequences of renal osteodystrophy in the dialysis population. Persistent hypophosphatemia may be observed with more frequent home hemodialysis regimens, but the specific effects on the skeleton are unknown. We present a patient with end-stage renal disease treated with frequent home hemodialysis who developed severe bone pain and multiple fractures, including a hip fracture and a tibia-fibula fracture complicated by nonunion, rendering her nonambulatory and wheelchair bound for more than a year. A bone biopsy revealed severe osteomalacia, likely secondary to chronic hypophosphatemia and hypocalcemia. Treatment changes included the addition of phosphate to the dialysate, a higher dialysate calcium concentration, and increased calcitriol dose. Several months later, the patient no longer required a wheelchair and was able to ambulate without pain. Repeat bone biopsy revealed marked improvements in bone mineralization and turnover parameters. Also, with increased dialysate phosphate and calcium concentrations, as well as increased calcitriol, circulating fibroblast growth factor 23 levels increased. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  4. The use of 3D-printed titanium mesh tray in treating complex comminuted mandibular fractures

    PubMed Central

    Ma, Junli; Ma, Limin; Wang, Zhifa; Zhu, Xiongjie; Wang, Weijian

    2017-01-01

    Abstract Rationale: Precise bony reduction and reconstruction of optimal contour in treating comminuted mandibular fractures is very difficult using traditional techniques and devices. The aim of this report is to introduce our experiences in using virtual surgery and three-dimensional (3D) printing technique in treating this clinical challenge. Patient concerns: A 26-year-old man presented with severe trauma in the maxillofacial area due to fall from height. Diagnosis: Computed tomography images revealed middle face fractures and comminuted mandibular fracture including bilateral condyles. Interventions and outcomes: The computed tomography data was used to construct the 3D cranio-maxillofacial models; then the displaced bone fragments were virtually reduced. On the basis of the finalized model, a customized titanium mesh tray was designed and fabricated using selective laser melting technology. During the surgery, a submandibular approach was adopted to repair the mandibular fracture. The reduction and fixation were performed according to preoperative plan, the bone defects in the mental area were reconstructed with iliac bone graft. The 3D-printed mesh tray served as an intraoperative template and carrier of bone graft. The healing process was uneventful, and the patient was satisfied with the mandible contour. Lessons: Virtual surgical planning combined with 3D printing technology enables surgeon to visualize the reduction process preoperatively and guide intraoperative reduction, making the reduction less time consuming and more precise. 3D-printed titanium mesh tray can provide more satisfactory esthetic outcomes in treating complex comminuted mandibular fractures. PMID:28682875

  5. Should lower limb fractures be treated surgically in patients with chronic spinal injuries? Experience in a reference centre.

    PubMed

    Barrera-Ochoa, S; Haddad, S; Rodríguez-Alabau, S; Teixidor, J; Tomás, J; Molero, V

    To report the outcomes of surgical treatment of lower limb fractures in patients with chronic spinal cord injuries. A total of 37 lower limb fractures were treated from 2003 to 2010, of which 25 fractures were treated surgically and 12 orthopaedically. Patients of the surgical group had better clinical results, range of motion, bone consolidation, and less pressure ulcers and radiological misalignment. No differences were detected between groups in terms of pain, hospital stay, and medical complications. There is no currently consensus regarding the management of lower limb fractures in patients with chronic spinal cord injuries, but the trend has been conservative treatment due to the high rate of complications in surgical treatment. Chronic spinal cord injuries patients with lower limb fractures who are treated surgically achieved a more reliable consolidation, practically a free range of motion, low rate of cutaneous complications, and pain associated with the fracture. This allows a quick return to the previous standard of living, and should be considered as an alternative to orthopaedic treatment in these patients. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Biochemical and Cellular Assessment of Acetabular Chondral Flaps Identified During Hip Arthroscopy.

    PubMed

    Hariri, Sanaz; Truntzer, Jeremy; Smith, Robert Lane; Safran, Marc R

    2015-06-01

    To analyze chondral flaps debrided during hip arthroscopy to determine their biochemical and cellular composition. Thirty-one full-thickness acetabular chondral flaps were collected during hip arthroscopy. Biochemical analysis was undertaken in 21 flaps from 20 patients, and cellular viability was determined in 10 flaps from 10 patients. Biochemical analysis included concentrations of (1) DNA (an indicator of chondrocyte content), (2) hydroxyproline (an indicator of collagen content), and (3) glycosaminoglycan (an indicator of chondrocyte biosynthesis). Higher values for these parameters indicated more healthy tissue. The flaps were examined to determine the percentage of viable chondrocytes. The percentage of acetabular chondral flap specimens that had concentrations within 1 SD of the mean values reported in previous normal cartilage studies was 38% for DNA, 0% for glycosaminoglycan, and 43% for hydroxyproline. The average cellular viability of our acetabular chondral flap specimens was 39% (SD, 14%). Only 2 of the 10 specimens had more than half the cells still viable. There was no correlation between (1) the gross examination of the joint or knowledge of the patient's demographic characteristics and symptoms and (2) biochemical properties and cell viability of the flap, with one exception: a degenerative appearance of the surrounding cartilage correlated with a higher hydroxyproline concentration. Although full-thickness acetabular chondral flaps can appear normal grossly, the biochemical properties and percentage of live chondrocytes in full-thickness chondral flaps encountered in hip arthroscopy show that this tissue is not normal. There has been recent interest in repairing chondral flaps encountered during hip arthroscopy. These data suggest that acetabular chondral flaps are not biochemically and cellularly normal. Although these flaps may still be valuable mechanically and/or as a scaffold in some conductive or inductive capacity, further study is

  7. Effect of remaining coronal structure on the resistance to fracture of crowned endodontically treated maxillary first premolars.

    PubMed

    Nissan, Joseph; Barnea, Eitan; Bar Hen, Doron; Assif, David

    2008-09-01

    Endodontically treated maxillary first premolars present a restorative challenge. The objective of the present study was to assess the resistance to fracture of crowned endodontically treated maxillary first premolars under simulated occlusal load, while preserving various degrees of remaining coronal structure. The study consisted of 50 intact maxillary first premolars with bifurcated roots and similar root diameter and length, randomly divided into 5 equal experimental groups. All dowels were luted with Flexi-Flow titanium-reinforced composite resin cement. TiCore titanium-reinforced composite resin was used to fabricate the core. Complete cast crowns were fabricated and cemented with zinc phosphate cement. Forces at fracture and mode of failure were recorded. Statistically significant differences (P < .05) were found among mean failure forces for all tested groups in their resistance to fracture under load with the Kruskal-Wallias test and among all combinations of the 5 groups (Z = -1.56/-2.34; P > .05) with the Mann-Whitney test. This indicates that crowned maxillary first premolars with varying degrees of remaining coronal structure differ significantly in their resistance to fracture under occlusal load. There was increased protection against fracture under occlusal loads with more remaining tooth structure. Within the limitations of this study, remaining coronal structure influenced the fracture resistance of crowned endodontically treated maxillary first premolars. Preservation of tooth structure is important for its protection against fracture under occlusal loads and may influence the tooth prognosis.

  8. The boiled-egg technique: a new method for obtaining femoral head autograft used in acetabular defect reconstruction.

    PubMed

    Bucknall, Vittoria; Mehdi, Ali

    2013-09-01

    Primary total hip arthroplasty can be complicated by acetabular bony defects, threatening the biomechanical integrity of the prosthesis. Traditionally, when autologous bone is used to pack these defects, it is obtained from thin slices of femoral head in addition to acetabular reamings. We report a novel technique for the acquisition of autologous femoral head bone graft used in the reconstruction of acetabular defects during primary total hip arthroplasty. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Myofascial treatment for patients with acetabular labral tears: a single-subject research design study.

    PubMed

    Cashman, Glenn E; Mortenson, W Ben; Gilbart, Michael K

    2014-08-01

    Single-subject research design using 4 consecutive patients. To assess whether treatment using soft tissue therapy (ART or Active Release Technique), stretching, and strengthening of the hip abductors, hip external rotators, and tensor fascia latae muscles reduces pain and improves self-reported hip function in patients with acetabular labral tears who also have posterolateral hip pain of suspected myofascial origin. Acetabular labral tears cause pain in some but not all patients. Pain commonly presents anteriorly but may also present posteriorly and laterally. The standard of care is arthroscopic repair, which helps many but not all patients. It is possible that these patients may present with extra-articular contributions to their pain, such as myofascial pain, making their clinical presentation more complex. No previous study has assessed soft tissue therapy as a treatment option for this subset of patients. This A-B-A design used repeated measures of the Hip Outcome Score and visual analog scale for pain. Four patients were treated for 6 to 8 weeks, using a combination of soft tissue therapy, stretching, and strengthening for the hip abductors, external rotators, and tensor fascia latae. Data were assessed visually, statistically, and by comparing mean differences before and after intervention. All 4 patients experienced both statistically significant and clinically meaningful improvement in posterolateral hip pain and hip-related function. Three patients also experienced reduction in anteromedial hip pain. Myofascial hip pain may contribute to hip-related symptoms and disability in patients with acetabular labral tears and posterolateral hip pain. These patients may benefit from soft tissue therapy combined with stretching and strengthening exercises targeting the hip abductors, tensor fascia latae, and hip external rotator muscles. Level of Evidence Therapy, level 4.

  10. Impaction grafted bone chip size effect on initial stability in an acetabular model: Mechanical evaluation.

    PubMed

    Holton, Colin; Bobak, Peter; Wilcox, Ruth; Jin, Zhongmin

    2013-01-01

    Acetabular bone defect reconstruction is an increasing problem for surgeons with patients undergoing complex primary or revision total hip replacement surgery. Impaction bone grafting is one technique that has favourable long-term clinical outcome results for patients who undergo this reconstruction method for acetabular bone defects. Creating initial mechanical stability of the impaction bone graft in this technique is known to be the key factor in achieving a favourable implant survival rate. Different sizes of bone chips were used in this technique to investigate if the size of bone chips used affected initial mechanical stability of a reconstructed acetabulum. Twenty acetabular models were created in total. Five control models were created with a cemented cup in a normal acetabulum. Then five models in three different groups of bone chip size were constructed. The three groups had an acetabular protrusion defect reconstructed using either; 2-4 mm(3), 10 mm(3) or 20 mm(3) bone chip size for impaction grafting reconstruction. The models underwent compression loading up to 9500 N and displacement within the acetabular model was measured indicating the initial mechanical stability. This study reveals that, although not statistically significant, the largest (20 mm(3)) bone chip size grafted models have an inferior maximum stiffness compared to the medium (10 mm(3)) bone chip size. Our study suggests that 10 mm(3) size of bone chips provide better initial mechanical stability compared to smaller or larger bone chips. We dismissed the previously held opinion that the biggest practically possible graft is best for acetabular bone graft impaction.

  11. Influence of ferrule preparation with or without glass fiber post on fracture resistance of endodontically treated teeth

    PubMed Central

    de LIMA, Alexandra Furtado; SPAZZIN, Aloísio Oro; GALAFASSI, Daniel; CORRER-SOBRINHO, Lourenço; CARLINI-JÚNIOR, Bruno

    2010-01-01

    Objective This study evaluated the effect of ferrule preparation (Fp) on the fracture resistance of endodontically treated teeth, restored with composite resin cores with or without glass fiber posts. Material and Methods Forty-four bovine teeth were sectioned 19 or 17 mm (2 mm ferrule) from the apex, endodontically treated and assigned to four groups (n = 11): Group 1: Fp and post; Group 2: Fp and without post; Group 3: without Fp and with post; Group 4: without Fp and without post. All specimens were restored with composite resin core and metal crown. Specimens were subjected to fracture resistance testing in a universal testing machine at a crosshead speed of 0.5 mm/min. The data were analyzed by two-way ANOVA and Tukey’s tests (α=0.05). Results The mean fracture resistance values were as follows: Group 1: 573.3 N; Group 2: 552.5 N; Group 3: 275.3 N; Group 4: 258.6 N. Significantly higher fracture resistance was found for the groups with Fp (p<0.001). Conclusion There was no statistically significant interaction between the "Fp" and "post" factors (p = 0.954). The ferrule preparation increased the fracture resistance of endodontically treated teeth. However, the use of glass fiber post showed no significant influence on the fracture resistance. PMID:20835570

  12. Cemented Total Hip Replacement Cable Debris and Acetabular Construct Durability

    PubMed Central

    Altenburg, Aaron J.; Callaghan, John J.; Yehyawi, Tameem M.; Pedersen, Douglas R.; Liu, Steve S.; Leinen, Jessica A.; Dahl, Kevin A.; Goetz, Devon D.; Brown, Thomas D.; Johnston, Richard C.

    2009-01-01

    Background: Third-body wear can adversely affect the outcome of total hip arthroplasty by causing increased polyethylene wear, osteolysis, and component loosening. We hypothesized that there would be greater generation and migration of metal debris to the bearing surfaces in hips in which cobalt-chromium cables were used to reattach the osteotomized greater trochanter when compared with hips in which stainless steel wires were used. Methods: Between June 1981 and December 1983, 196 consecutive total hip arthroplasties were performed with use of an Iowa stem and a titanium-backed cemented acetabular component, with cobalt-chromium cable trochanteric reattachment. After nineteen to twenty years of follow-up, the patients were evaluated with regard to the depth of head penetration into the polyethylene (as a surrogate for wear), osteolysis, loosening, and the need for revision. The results were compared with those for a series of 304 total hip arthroplasties that were performed by the same surgeon from January 1984 to December 1985 with use of the same components and the same surgical technique, but with stainless steel wire trochanteric reattachment. The two groups had a comparable nineteen to twenty-year follow-up. All living patients (fifty-nine hips in the cable group and ninety-two hips in the wire group) had minimum ten-year follow-up radiographs. Results: The polyethylene wear rate was 0.101 mm/yr for the cable group and 0.082 mm/yr for the wire group (p = 0.039). For the living patients, the rate of revision of the acetabular component because of aseptic loosening was 37.3% (twenty-two hips) for the cable group and 20.7% (nineteen hips) for the wire group (p = 0.025). The rate of acetabular osteolysis was 44% (twenty-six hips) for the cable group and 26% (twenty-four hips) for the wire group (p = 0.022). Kaplan-Meier analysis with revision of the acetabular component because of aseptic loosening as the end point demonstrated survival rates of 73.7% ± 9% and

  13. Comparison of Early and Delayed Open Reduction and Internal Fixation for Treating Closed Tibial Pilon Fractures.

    PubMed

    Tang, Xin; Liu, Lei; Tu, Chong-qi; Li, Jian; Li, Qi; Pei, Fu-xing

    2014-07-01

    The timing of surgery for osteosynthesis of type C pilon (AO/OTA) fractures remains controversial. The aim of this study was to determine the outcome of early and delayed open reduction and internal fixation (ORIF) for treating closed type C pilon fractures. Forty-six patients with closed type C pilon fractures matched according to age, gender, soft tissue conditions, and fracture pattern were divided into group A (early group: underwent surgery within 36 hours of the injury) or group B (delayed group: underwent surgery 10 days to 3 weeks postinjury after the soft tissue swelling subsided). In the delayed group, 9 patients were treated first by temporary external fixation. All the closed fractures were managed by ORIF with locking plates. At follow-up, the clinical and radiographic results were retrospectively analyzed. The mean follow-up time was 25.8 months (range, 14 to 48 months) in group A and 26.0 months (range, 15 to 44 months) in group B. There was no significant difference (P > .05) between the 2 groups regarding the rate of soft tissue complication, the rate of fracture union, and the final functional score. The patients in group A had a significantly shorter mean time to fracture union (21.5 ± 4.0 weeks vs 23.3 ± 3.7 weeks, P < .05), operating time (84.3 ± 12.1 months vs 100.6 ± 13.7 months, P < .01), and hospital stay (7.6 ± 2.6 days vs 15.2 ± 4.2 days, P < .01). If soft tissue conditions are acceptable, early ORIF for treating closed type C pilon fractures can be safe and effective, with similar rates of wound complication, fracture union, and final good functional recovery but shorter operative time, union time, and hospital stay. These results favorably compare with delayed ORIF treatment. Level III, retrospective comparative study. © The Author(s) 2014.

  14. Acetabular overcoverage in the horizontal plane: an underdiagnosed trigger of early hip arthritis. A CT scan study in young adults.

    PubMed

    Valera, Màrius; Ibáñez, Natalia; Sancho, Rogelio; Llauger, Jaume; Gich, Ignasi

    2018-01-01

    Acetabular overcoverage promotes hip osteoarthritis causing a pincer-type femoroacetabular impingement. Acetabular coverage in the horizontal plane is usually poorly defined in imaging studies and may be misdiagnosed. The goal of this study was to analyze the role of acetabular overcoverage measured in the frontal plane and in the horizontal plane by CT scan and to determine its relationship with other anatomic features in the onset of hip arthritis in young adults. We compared prospectively CT scans from two groups of adults of 55 years or younger: the patient group (n = 30) consisted of subjects with diagnosis of early hip arthritis (Tönnis Grade I or II) and the control group (n = 31) consisted of subjects with healthy hips. Two independent observers analyzed centre edge angle (CEA), acetabular anteversion angle (AAA), anterior sector acetabular angle (AASA), posterior sector acetabular angle (PASA), horizontal acetabular sector angle (HASA), femoral anteversion angle (FAVA), alpha angle (AA), and Mckibbin Instability Index (MI). Angles measuring the acetabular coverage on the horizontal plane (AASA, PASA and, HASA) were significantly higher in the patient group (p < 0.001, p = 0.03 and p < 0.001, respectively). Pearson's correlation coefficient showed a positive correlation between CEA and HASA in patients (r = 0.628) and in controls (r = 0.660). However, a high CEA (> 35º) was strongly associated with a high HASA (> 160º) in patients (p = 0.024) but not in controls (p = 0.21), suggesting that pincer should be simultaneously present in the horizontal and frontal plane to trigger hip degeneration. No significant association was detected between a high alpha angle (> 60º) and a high CEA (> 35º suggesting that a mixed pincer-cam aetiology was not prevalent in our series. Multivariate regression analysis showed the most significant predictors of degenerative joint disease were HASA (p = 0.008), AA (p = 0.048) and ASAA (p = 0

  15. Improving the accuracy of acetabular cup implantation using a bulls-eye spirit level.

    PubMed

    Macdonald, Duncan; Gupta, Sanjay; Ohly, Nicholas E; Patil, Sanjeev; Meek, R; Mohammed, Aslam

    2011-01-01

    Acetabular introducers have a built-in inclination of 45 degrees to the handle shaft. With patients in the lateral position, surgeons aim to align the introducer shaft vertical to the floor to implant the acetabulum at 45 degrees. We aimed to determine if a bulls-eye spirit level attached to an introducer improved the accuracy of implantation. A small circular bulls-eye spirit level was attached to the handle of an acetabular introducer. A saw bone hemipelvis was fixed to a horizontal, flat surface. A cement substitute was placed in the acetabulum and subjects were asked to implant a polyethylene cup, aiming to obtain an angle of inclination of 45 degrees. Two attempts were made with the spirit level masked and two with it unmasked. The distance of the air bubble from the spirit level's center was recorded by a single assessor. The angle of inclination of the acetabular component was then calculated. Subjects included both orthopedic consultants and trainees. Twenty-five subjects completed the study. Accuracy of acetabular implantation when using the unmasked spirit level improved significantly in all grades of surgeon. With the spirit level masked, 12 out of 50 attempts were accurate at 45 degrees inclination; 11 out of 50 attempts were "open," with greater than 45 degrees of inclination, and 27 were "closed," with less than 45 degrees. With the spirit level visible, all subjects achieved an inclination angle of exactly 45 degrees. A simple device attached to the handle of an acetabular introducer can significantly improve the accuracy of implantation of a cemented cup into a saw bone pelvis in the lateral position.

  16. Fracture resistance and primary failure mode of endodontically treated teeth restored with a carbon fiber-reinforced resin post system in vitro.

    PubMed

    Raygot, C G; Chai, J; Jameson, D L

    2001-01-01

    This study was undertaken to characterize the fracture resistance and mode of fracture of endodontically treated incisors restored with cast post-and-core, prefabricated stainless steel post, or carbon fiber-reinforced composite post systems. Ten endodontically treated teeth restored with each technique were subjected to a compressive load delivered at a 130-degree angle to the long axis until the first sign of failure was noted. The fracture load and the mode of fracture were recorded. The failure loads registered in the three groups were not significantly different. Between 70%, and 80% of teeth from any of the three groups displayed fractures that were located above the simulated bone level. The use of carbon fiber-reinforced composite posts did not change the fracture resistance or the failure mode of endodontically treated central incisors compared to the use of metallic posts.

  17. Pelvic Incidence and Acetabular Version in Slipped Capital Femoral Epiphysis.

    PubMed

    Gebhart, Jeremy J; Bohl, Michael S; Weinberg, Douglas S; Cooperman, Daniel R; Liu, Raymond W

    2015-09-01

    The etiology of slipped capital femoral epiphysis (SCFE) is multifactorial, but the role of sagittal balance of the pelvis as a contributing factor to its development has not been well studied. Our primary purpose was to determine whether a smaller pelvic incidence (PI), a position-independent anatomic parameter that regulates pelvic orientation, could be a factor that increases shear stress in the epiphyseal growth plate and potentially contributes to the development of SCFE. We also set out to determine whether acetabular retroversion was associated with SCFE. We obtained 14 cadaveric pelvi from the Hamann-Todd Osteological Collection whose femurs showed evidence of post-SCFE deformity. Two hundred age-matched, sex-matched, and race-matched pelvi were used as controls. PI and acetabular version were measured using standardized lateral photographs and goniometers, respectively. T tests were performed to evaluate for differences in measured parameters between groups. The mean PI was 40.6±6.1 degrees for SCFE specimens and 47.4±9.9 degrees for normal specimens (P=0.01). The mean version of SCFE and normal acetabula was 15±7 and 17±6 degrees, respectively (P=0.39). There was also no significant difference in version between SCFE acetabula and the contralateral, uninvolved acetabular of the same specimen (15±7 vs. 17±8 degrees, P=0.33). Specimens with SCFE deformity demonstrated a smaller PI than a large cohort of normal control specimens. We found no significant difference between acetabular version of specimens with and without SCFE deformity. Contralateral or unaffected acetabuli of SCFE specimens were not more retroverted than the affected side of the same specimen. Sagittal balance of the pelvis, and particularly decreased PI, may play an important role in the development of SCFE. The influence of mechanical factors beyond the hip joint in the development of SCFE should be considered by clinicians.

  18. Does Increased Coefficient of Friction of Highly Porous Metal Increase Initial Stability at the Acetabular Interface?

    PubMed

    Goldman, Ashton H; Armstrong, Lucas C; Owen, John R; Wayne, Jennifer S; Jiranek, William A

    2016-03-01

    Highly porous metal acetabular components illustrate a decreased rate of aseptic loosening in short-term follow-up compared with previous registry data. This study compared the effect of component surface roughness at the bone-implant interface and the quality of the bone on initial pressfit stability. The null hypothesis is that a standard porous coated acetabular cup would show no difference in initial stability as compared with a highly porous acetabular cup when subjected to a bending moment. Second, would bone mineral density (BMD) be a significant variable under these test conditions. In a cadaveric model, acetabular cup micromotion was measured during a 1-time cantilever bending moment applied to 2 generations of pressfit acetabular components. BMD data were also obtained from the femoral necks available for associated specimen. The mean bending moment at 150 μm was not found to be significantly different for Gription (24.6 ± 14.0 N m) cups vs Porocoat (25 ± 10.2 N m; P > .84). The peak bending moment tolerated by Gription cups (33.9 ± 20.3 N m) was not found to be significantly different from Porocoat (33.5 ± 12.2 N m; P > .92). No correlation between BMD and bending moment at 150 μm of displacement could be identified. The coefficient of friction provided by highly porous metal acetabular shells used in this study did not provide better resistance to migration under bending load when compared with a standard porous coated component. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Interventions for treating proximal humeral fractures in adults.

    PubMed

    Handoll, Helen H G; Ollivere, Benjamin J; Rollins, Katie E

    2012-12-12

    displaced and/or complex fractures, compared surgical versus conservative treatment. Pooled results of patient-reported functional scores at one year from three trials (153 participants) showed no statistically significant difference between the two groups (standardised mean difference -0.10, 95% CI -0.42 to 0.22; negative results favour surgery). Quality of life based on the EuroQol results scores from three trials (153 participants) showed non-statistically significant differences between the two groups at three time points up to 12 months. However, the pooled EuroQol results at two years (101 participants) from two trials run concurrently from the same centre were significantly in favour of the surgical group. There was no significant difference between the two groups in mortality (8/98 versus 5/98; RR 1.55, 95% CI 0.55 to 4.36; 4 trials). Significantly more surgical group patients had additional or secondary surgery (18/112 versus 5/111; RR 3.36, 95% CI 1.33 to 8.49; 5 trials). This is equivalent to an extra operation in one of every nine surgically treated patients.Different methods of surgical management were tested in seven small trials. One trial comparing two types of locking plate versus a locking nail for treating two-part surgical neck fractures found some evidence of better function after plate fixation but also of a higher rate of surgically-related complications. One trial comparing a locking plate versus minimally invasive fixation with distally inserted intramedullary nails found some evidence of a short-term benefit for the nailing group. Compared with hemiarthroplasty, tension-band fixation of severe injuries using wires was associated with a higher re-operation rate in one trial. Two trials found no important differences between 'polyaxial' and 'monaxial' screws combined with locking plate fixation. One trial produced some preliminary evidence that tended to support the use of medial support locking screws in locking plate fixation. One trial found

  20. Anterior tibial stress fractures treated with anterior tension band plating in high-performance athletes.

    PubMed

    Cruz, Alexandre Santa; de Hollanda, João Paris Buarque; Duarte, Aires; Hungria Neto, José Soares

    2013-06-01

    The non-surgical treatment of anterior tibial cortex stress fractures requires long periods of abstention from sports activities and often results in non-union. Many different surgical techniques have already been previously described to treat these fractures, but there is no consensus on the best treatment. We describe the outcome of treatment using anterior tibial tension band plating in three high-performance athletes (4 legs) with anterior tibial cortex stress fractures. Tibial osteosynthesis with a 3.5-mm locking compression plate in the anterolateral aspect of the tibia was performed in all patients diagnosed with anterior tibial stress fracture after September 2010 at Santa Casa Hospital. All of the fractures were consolidated within a period of 3 months after surgery, allowing for an early return to pre-injury levels of competitive sports activity. There were no infection, non-union, malunion or anterior knee pain complications. Anterior tibial tension band plating leads to prompt fracture consolidation and is a good alternative for the treatment of anterior tibial cortex stress fractures. Bone grafts were shown to be unnecessary.

  1. Biomechanical investigation of titanium elastic nail prebending for treating diaphyseal long bone fractures.

    PubMed

    Chen, Yen-Nien; Lee, Pei-Yuan; Chang, Chih-Wei; Ho, Yi-Hung; Peng, Yao-Te; Chang, Chih-Han; Li, Chun-Ting

    2017-03-01

    This study numerically investigated the deformation of titanium elastic nails prebent at various degrees during implantation into the intramedullary canal of fractured bones and the mechanism by which this prebending influenced the stability of the fractured bone. Three degrees of prebending the implanted portions of the nails were used: equal to, two times, and three times the diameter of the intramedullary canal. Furthermore, a simulated diaphyseal fracture with a 5-mm gap was created in the middle shaft portion of the bone fixed with two elastic nails in a double C-type configuration. End caps were simulated using a constraint equation. To confirm that the simulation process is able to present the mechanical response of the nail inside the intramedullary, an experiment was conducted by using sawbone for validation. The results indicated that increasing the degrees of nail prebending facilitated straightening the nails against the inner aspect of canal after implantation, with increase in stability under torsion. Furthermore, reducing nail prebending caused a larger portion of the nails to move closer to the loading site and center of bone after implantation; the use of end caps prevented the nail tips from collapsing and increased axial stability. End cap use was critical for preventing the nail tips from collapsing and for increasing the stability of the nails prebent at a degree equal to the diameter of the canal with insufficient frictional force between the nail and canal. Therefore, titanium elastic nail prebending in a double C-type configuration with a degree three times the diameter of the canal represents a superior solution for treating transverse fractures without a gap, whereas that with a degree equal to the diameter of the intramedullary canal and combined with end cap use represents an advanced solution for treating comminuted fractures in a diaphyseal long bone fracture.

  2. Preferences of orthopedic surgeons for treating midshaft clavicle fracture in adults

    PubMed Central

    de Oliveira, Adilson Sanches; Roberto, Bruno Braga; Lenza, Mario; Pintan, Guilherme Figueiredo; Ejnisman, Benno; Schor, Breno; Carrera, Eduardo da Frota; Murachovsky, Joel

    2017-01-01

    ABSTRACT Objective To determine the current clinical practice in Latin America for treating midshaft clavicle fractures, including surgical and non-surgical approaches. Methods A cross-sectional study using a descriptive questionnaire. Shoulder and elbow surgeons from the Brazilian Society of Shoulder and Elbow Surgery and from the Latin American Society of Shoulder and Elbow were contacted and asked to complete a short questionnaire (SurveyMonkey®) on the management of midshaft fractures of the clavicle. Incomplete or inconsistent answers were excluded. Results The type of radiographic classification preferably used was related to description of fracture morphology, according to 41% of participants. Allman classification ranked second and was used by 24.1% of participants. As to indications for surgical treatment, only the indications with shortening and imminence of skin exposure were statistically significant. Conservative treatment was chosen in cortical contact. Regarding immobilization method, the simple sling was preferred, and treatment lasted from 4 to 6 weeks. Although the result was not statistically significant, the blocked plate was the preferred option in surgical cases. Conclusion The treatment of midshaft clavicle fractures in Latin America is in accordance with the current literature. PMID:29091151

  3. Analysis of acetabular orientation and femoral anteversion using images of three-dimensional reconstructed bone models.

    PubMed

    Park, Jaeyeong; Kim, Jun-Young; Kim, Hyun Deok; Kim, Young Cheol; Seo, Anna; Je, Minkyu; Mun, Jong Uk; Kim, Bia; Park, Il Hyung; Kim, Shin-Yoon

    2017-05-01

    Radiographic measurements using two-dimensional (2D) plain radiographs or planes from computed tomography (CT) scans have several drawbacks, while measurements using images of three-dimensional (3D) reconstructed bone models can provide more consistent anthropometric information. We compared the consistency of results using measurements based on images of 3D reconstructed bone models (3D measurements) with those using planes from CT scans (measurements using 2D slice images). Ninety-six of 561 patients who had undergone deep vein thrombosis-CT between January 2013 and November 2014 were randomly selected. We evaluated measurements using 2D slice images and 3D measurements. The images used for 3D reconstruction of bone models were obtained and measured using [Formula: see text] and [Formula: see text] (Materialize, Leuven, Belgium). The mean acetabular inclination, acetabular anteversion and femoral anteversion values on 2D slice images were 42.01[Formula: see text], 18.64[Formula: see text] and 14.44[Formula: see text], respectively, while those using images of 3D reconstructed bone models were 52.80[Formula: see text], 14.98[Formula: see text] and 17.26[Formula: see text]. Intra-rater reliabilities for acetabular inclination, acetabular anteversion, and femoral anteversion on 2D slice images were 0.55, 0.81, and 0.85, respectively, while those for 3D measurements were 0.98, 0.99, and 0.98. Inter-rater reliabilities for acetabular inclination, acetabular anteversion and femoral anteversion on 2D slice images were 0.48, 0.86, and 0.84, respectively, while those for 3D measurements were 0.97, 0.99, and 0.97. The differences between the two measurements are explained by the use of different tools. However, more consistent measurements were possible using the images of 3D reconstructed bone models. Therefore, 3D measurement can be a good alternative to measurement using 2D slice images.

  4. Morphometric assessment of hip dysplasia in a cat treated by juvenile pubic symphysiodesis.

    PubMed

    Lai, Alen; Culvenor, John; Bailey, Craig

    2016-09-20

    To quantitatively evaluate the change of the coxofemoral joints using computed tomography and distraction index in a cat with hip dysplasia treated by juvenile pubic symphysiodesis. Case report. Eighteen-week-old female entire Maine Coon cat. Juvenile pubic symphysiodesis resulted in changes in the distraction index, acetabular angle, dorsal acetabular rim angle, dorsal acetabular sector angle, and clinical improvement at the six month follow-up. No intra-operative or postoperative complications were recorded. Juvenile pubic symphysiodesis performed at 18 weeks of age resulted in improvement in hip joint conformation and hip laxity in a dysplastic cat. Juvenile pubic symphysiodesis may be a promising treatment for feline hip dysplasia and is a safe and technically simple procedure to perform. Further investigations are warranted.

  5. Surgical Strategy and Techniques for Low-Profile Dorsal Plating in Treating Dorsally Displaced Unstable Distal Radius Fractures

    PubMed Central

    Hamada, Yoshitaka; Gotani, Hiroyuki; Hibino, Naohito; Tanaka, Yoshitaka; Satoh, Ryousuke; Sasaki, Kousuke; Kanchanathepsak, Thepparat

    2016-01-01

    Background The low-profile dorsal locking plating (DLP) technique is useful for treating dorsally comminuted intra-articular distal radius fractures; however, due to the complications associated with DLP, the technique is not widely used. Methods A retrospective review of 24 consecutive cases treated with DLP were done. Results All cases were classified into two types by surgical strategy according to the fracture pattern. In type 1, there is a volar fracture line distal to the watershed line in the dorsally displaced fragment, and this type is treated by H-framed DLP. In type 2, the displaced dorsal die-punch fragment is associated with a minimally displaced styloid shearing fracture or a transverse volar fracture line. We found that the die-punch fragment was reduced by the buttress effect of small l-shaped DLP after stabilization of the styloid shearing for the volar segment by cannulated screws from radial styloid processes. At 6 months after surgery, outcomes were good or excellent based on the modified Mayo wrist scores with no serious complications except one case. The mean range of motion of each type was as follows: the palmar flexion was 50, 65 degrees, dorsiflexion was 70, 75 degrees, supination was 85, 85 degrees, and pronation was 80, 80 degrees; in type 1 and 2, respectively. Conclusion DLP is a useful technique for the treatment of selected cases of dorsally displaced, comminuted intra-articular fractures of the distal radius with careful soft tissue coverage. PMID:28428920

  6. Complications Are Not Increased With Acetabular Revision of Metal-on-metal Total Hip Arthroplasty.

    PubMed

    Penrose, Colin T; Seyler, Thorsten M; Wellman, Samuel S; Bolognesi, Michael P; Lachiewicz, Paul F

    2016-10-01

    Isolated revision of the acetabular component in the setting of total hip arthroplasty has an increased risk of dislocation. With local soft tissue destruction frequently associated with failed metal-on-metal (MoM) bearings, it is presumed that acetabular revision of these hips will have even greater risk of complications. However, no study directly compares the complications of MoM with metal-on-polyethylene (MoP) acetabular revisions. In the context of a large database analysis, we asked the following questions: (1) Are there differences in early medical or wound complications after isolated acetabular revision of MoM and MoP bearing surfaces? (2) Are there differences in the frequency of dislocation, deep infection, and rerevision based on the bearing surface of the original implant? A review of the 100% Medicare database from 2005 to 2012 was performed using International Classification of Diseases, 9th Revision and Current Procedural Terminology codes. We identified 451 patients with a MoM bearing and 628 patients with a MoP bearing who had an isolated acetabular revision and a minimum followup of 2 years. The incidence, odds ratios, and 95% confidence intervals for early medical or wound complications were calculated using a univariate analysis at 30 days with patient sex and age group-adjusted analysis for blood transfusion. The incidence, odds ratio, and 95% confidence intervals for dislocation, deep infection, and rerevision were calculated using a univariate analysis at 30 day, 90 days, 1 year, and 2 years using a subgroup analysis with the Cochran-Mantel-Haenszel test to adjust for patient gender and age groups. There were no differences between the MoM and MoP isolated acetabular revisions in the incidence of 30-day local complications. There was a greater risk of transfusion in the MoP group than the MoM group (134 of 451 [30%] versus 230 of 628 [37%]; odds ratio [OR], 0.731; 95% confidence interval [CI], 0.565-0.948; p = 0.018). There were no

  7. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented acetabular...

  8. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented acetabular...

  9. Assessment of acetabular retroversion following long term review of Salter's osteotomy.

    PubMed

    Robb, Curtis A; Datta, Amit; Nayeemuddin, Mohammed; Bache, Christopher E

    2009-01-01

    Salter's innominate osteotomy may predispose to anterior over-coverage of the acetabulum. Over cover or retroversion has been demonstrated to be a cause of hip pain, impingement and subsequent osteoarthritis. We reviewed the long-term follow up of seventeen skeletally mature hips in sixteen patients who had previously undergone a Salter's osteotomy in childhood. The Salter pelvic osteotomy was performed at a mean average age of 5 years and follow up at a mean average age of 20 years. Patients were assessed by clinical examination for signs of impingement, Harris Hip Score and pelvic radiograph. Acetabular version was evaluated by the relationship between anterior and posterior walls of the acetabulum using templates applied to the pelvic radiograph as described by Hefti. The median acetabular cover averaged 17 degrees of anteversion with 2 patients (12%) demonstrating retroversion, neither of whom, had signs of impingement on examination. The mean average Harris Hip Score was 85 indicating a good outcome at long-term follow-up. We believe acetabular remodelling may occur with age after Salter's innominate osteotomy and have found good results in patients after skeletal maturation. Fears of long-term anterior over-coverage and retroversion with this operation may be unfounded.

  10. Initial stability of press-fit acetabular components under rotational forces.

    PubMed

    Fehring, Keith A; Owen, John R; Kurdin, Anton A; Wayne, Jennifer S; Jiranek, William A

    2014-05-01

    The primary goal of this study was to determine the initial press-fit stability in acetabular components without screw fixation. Mechanical testing was performed with the implantation of press-fit acetabular components in cadaveric specimens. No significant difference was found in load to failure testing between 1 and 2 mm of under-reaming. However, there was significant variability in bending forces required to create 150 μm of micromotion ranging from 49.3 N to 214.4 N. This study shows that cups implanted in a press-fit fashion, which are felt to be clinically stable, have high degrees of variability in resisting load and may be at risk for loosening. There is a need for more objective intra-operative techniques to test cup stability. © 2014.

  11. The influence of acetabular bone cracks in the press-fit hip replacement: Numerical and experimental analysis.

    PubMed

    Ramos, A; Duarte, R J; Relvas, C; Completo, A; Simões, J A

    2013-07-01

    The press-fit hip acetabular prosthesis implantation can cause crack formation in the thin regions surrounding the acetabular. As a consequence the presence of cracks in this region can lead to poor fixation and fibrous tissue formation. Numerical and experimental models of commercial press-fit hip replacements were developed to compare the behavior between the intact and implanted joints. Numerical models with an artificial crack and without crack were considered. The iliac and the femur were created through 3D geometry acquisition based on composite human replicas and 3D-Finite Element models were generated. The mechanical behavior was assessed numerically and experimentally considering the principal strains. The comparison between Finite Element model predictions and experimental measurements revealed a maximum difference of 9%. Similar distribution of the principal strains around the acetabular cavity was obtained for the intact and implanted models. When comparing the Von Mises stresses, it is possible to observe that the intact model is the one that presents the highest stress values in the entire acetabular cavity surface. The crack in the posterior side changes significantly the principal strain distribution, suggesting bone loss after hip replacement. Relatively to micromotions, these were higher on the superior side of the acetabular cavity and can change the implant stability and bone ingrowth. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. A Pilot Study of Augmented Reality Technology Applied to the Acetabular Cup Placement During Total Hip Arthroplasty.

    PubMed

    Ogawa, Hiroyuki; Hasegawa, Seiichirou; Tsukada, Sachiyuki; Matsubara, Masaaki

    2018-06-01

    We developed an acetabular cup placement device, the AR-HIP system, using augmented reality (AR). The AR-HIP system allows the surgeon to view an acetabular cup image superimposed in the surgical field through a smartphone. The smartphone also shows the placement angle of the acetabular cup. This preliminary study was performed to assess the accuracy of the AR-HIP system for acetabular cup placement during total hip arthroplasty (THA). We prospectively measured the placement angles using both a goniometer and AR-HIP system in 56 hips of 54 patients undergoing primary THA. We randomly determined the order of intraoperative measurement using the 2 devices. At 3 months after THA, the placement angle of the acetabular cup was measured on computed tomography images. The primary outcome was the absolute value of the difference between intraoperative and postoperative computed tomography measurements. The measurement angle using AR-HIP was significantly more accurate in terms of radiographic anteversion than that using a goniometer (2.7° vs 6.8°, respectively; mean difference 4.1°; 95% confidence interval, 3.0-5.2; P < .0001). There was no statistically significant difference in terms of radiographic inclination (2.1° vs 2.6°; mean difference 0.5°; 95% confidence interval, -1.1 to 0.1; P = .13). In this pilot study, the AR-HIP system provided more accurate information regarding acetabular cup placement angle than the conventional method. Further studies are required to confirm the utility of the AR-HIP system as a navigation tool. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Outcome of Boxer’s Fractures Treated by a Soft Wrap and Buddy Taping: A Prospective Study

    PubMed Central

    Kämpfen, Stephan; Berli, Martin; Fritschy, Daniel; Della Santa, Dominique; Fusetti, Cesare

    2007-01-01

    Introduction The ideal treatment for a boxer’s fracture remains controversial, particularly the degree of volar dislocation considered acceptable for nonoperative treatment. Patients and Methods From December 2003 to December 2004, 25 patients who sustained a subcapital metacarpal fracture of the little finger with volar angulation between 30 to 75° were prospectively enrolled in the study. All patients were treated with a circular self-adherent wrap covering metacarpal bones II–V and buddy taping of the ring and little fingers for a period of 3 weeks while allowing immediate free range of motion. Results Final evaluation at a mean of 5 months revealed all patients to be satisfied without subjective functional impairment. All fractures healed, and the angulation of the fracture remained unchanged, but moderate shortening was observed. Active flexion of the metacarpophalangeal (MCP) joint was significantly lower on the fracture side, but as the median degree of MCP flexion was the same, this statistical difference was without clinical relevance. There was no loss in grip strength. A subjective long-term evaluation was performed by phone; at a median of 3 years, a QuickDash score gave a median of 0 point. Conclusion Treating a boxer’s fracture with angulation of up to 75° by soft wrap and buddy taping resulted in satisfied patients and good clinical results. PMID:18780055

  14. [A simulative biomechanical experiment on different position of none-cement acetabular components influencing the load distribution around acetabulum].

    PubMed

    Li, Dongsong; Liu, Jianguo; Li, Shuqiang; Fan, Honghui; Guan, Jikui

    2008-02-01

    In the present study, a three dimensional finite-element model of the human pelvic was reconstructed, and then, under different acetabular component position (the abduction angle ranges from 30 degrees to 70 degrees and the anteversion ranges from 5 degrees to 30degrees) the load distribution around the acetabular was evaluated by the computer biomechanical analysis program (Solidworks). Through the obtained load distribution results, the most even and reasonable range of the distribution was selected; therefore the safe range of the acetabular component implantation can be validated from the biomechanics aspect.

  15. Can acetabular orientation be restored by lumbar pedicle subtraction osteotomy in ankylosing spondylitis patients with thoracolumbar kyphosis?

    PubMed

    Hu, Jun; Qian, Bang-Ping; Qiu, Yong; Wang, Bin; Yu, Yang; Zhu, Ze-Zhang; Jiang, Jun; Mao, Sai-Hu; Qu, Zhe; Zhang, Yun-Peng

    2017-07-01

    To evaluate whether acetabular orientation (abduction and anteversion) can be restored by lumbar pedicle subtraction osteotomy (PSO) in ankylosing spondylitis (AS) patients with thoracolumbar kyphosis. A total of 33 consecutive AS patients with thoracolumbar kyphosis undergoing one-level lumbar PSO were retrospectively reviewed. Radiographical measurements included sagittal vertical axis, global kyphosis, thoracic kyphosis, local kyphosis, lumbar lordosis, pelvic incidence, sacral slope, and pelvic tilt. Acetabular abduction and anteversion were measured on CT scans of the pelvis before and after lumbar PSO. The preoperative and postoperative parameters were compared by the paired samples t test. Pearson's correlation analysis was conducted to determine the correlations between the changes in acetabular abduction and anteversion and the changes in sagittal spinopelvic parameters. After lumbar PSO, sagittal vertical axis, global kyphosis, and pelvic tilt were corrected from 15.7 ± 6.7 cm, 66.8° ± 17.5°, and 38.6° ± 9.0° to 2.9 ± 4.9 cm, 21.3° ± 8.2°, and 23.2° ± 8.2°, respectively (p < 0.001). Of note, acetabular abduction and anteversion decreased from 59.6° ± 4.6° to 31.4° ± 6.5° before surgery to 51.4° ± 6.5° and 20.2° ± 4.4° after surgery, respectively (p < 0.001). Moreover, the changes in acetabular abduction and anteversion were observed significantly correlated with the change in pelvic tilt (r = 0.527, p = 0.002; r = 0.586, p < 0.001). Abnormal acetabular abduction and anteversion could be corrected by lumbar PSO in AS patients with thoracolumbar kyphosis. Consequently, a relatively normal acetabular orientation could be achieved after lumbar PSO, which might decrease the potential risk of dislocation in AS patients with spine and hip deformities requiring subsequent THR surgery.

  16. Distal tibial pilon fractures (AO/OTA type B, and C) treated with the external skeletal and minimal internal fixation method.

    PubMed

    Milenković, Sasa; Mitković, Milorad; Micić, Ivan; Mladenović, Desimir; Najman, Stevo; Trajanović, Miroslav; Manić, Miodrag; Mitković, Milan

    2013-09-01

    Distal tibial pilon fractures include extra-articular fractures of the tibial metaphysis and the more severe intra-articular tibial pilon fractures. There is no universal method for treating distal tibial pilon fractures. These fractures are treated by means of open reduction, internal fixation (ORIF) and external skeletal fixation. The high rate of soft-tissue complications associated with primary ORIF of pilon fractures led to the use of external skeletal fixation, with limited internal fixation as an alternative technique for definitive management. The aim of this study was to estimate efficacy of distal tibial pilon fratures treatment using the external skeletal and minimal internal fixation method. We presented a series of 31 operated patients with tibial pilon fractures. The patients were operated on using the method of external skeletal fixation with a minimal internal fixation. According to the AO/OTA classification, 17 patients had type B fracture and 14 patients type C fractures. The rigid external skeletal fixation was transformed into a dynamic external skeletal fixation 6 weeks post-surgery. This retrospective study involved 31 patients with tibial pilon fractures, average age 41.81 (from 21 to 60) years. The average follow-up was 21.86 (from 12 to 48) months. The percentage of union was 90.32%, nonunion 3.22% and malunion 6.45%. The mean to fracture union was 14 (range 12-20) weeks. There were 4 (12.19%) infections around the pins of the external skeletal fixator and one (3.22%) deep infections. The ankle joint arthrosis as a late complication appeared in 4 (12.90%) patients. All arthroses appeared in patients who had type C fractures. The final functional results based on the AOFAS score were excellent in 51.61%, good in 32.25%, average in 12.90% and bad in 3.22% of the patients. External skeletal fixation and minimal internal fixation of distal tibial pilon fractures is a good method for treating all types of inta-articular pilon fractures. In

  17. Sex assessment from the acetabular rim by means of image analysis.

    PubMed

    Benazzi, S; Maestri, C; Parisini, S; Vecchi, F; Gruppioni, G

    2008-08-25

    Determining sex from skeletal remains is one of the most important steps in archaeological and forensic anthropology. The present study considers the diagnostic value of the acetabulum based on its planar image and related metric data. For this purpose, 83 adult os coxae of known age were examined. Digital photos of the acetabular area were taken, with each bone in a standardized orientation. Technical drawing software was used to trace the acetabular rim and to measure the related dimensions (area, perimeter, longitudinal and transverse maximum width). The measurements were subjected to SPSS discriminant and classification function analysis. There were significant differences (p

  18. A novel approach for determining three-dimensional acetabular orientation: results from two hundred subjects.

    PubMed

    Higgins, Sean W; Spratley, E Meade; Boe, Richard A; Hayes, Curtis W; Jiranek, William A; Wayne, Jennifer S

    2014-11-05

    The inherently complex three-dimensional morphology of both the pelvis and acetabulum create difficulties in accurately determining acetabular orientation. Our objectives were to develop a reliable and accurate methodology for determining three-dimensional acetabular orientation and to utilize it to describe relevant characteristics of a large population of subjects without apparent hip pathology. High-resolution computed tomography studies of 200 patients previously receiving pelvic scans for indications not related to orthopaedic conditions were selected from our institution's database. Three-dimensional models of each osseous pelvis were generated to extract specific anatomical data sets. A novel computational method was developed to determine standard measures of three-dimensional acetabular orientation within an automatically identified anterior pelvic plane reference frame. Automatically selected points on the osseous ridge of the acetabulum were used to generate a best-fit plane for describing acetabular orientation. Our method showed excellent interobserver and intraobserver agreement (an intraclass correlation coefficient [ICC] of >0.999) and achieved high levels of accuracy. A significant difference between males and females in both anteversion (average, 3.5°; 95% confidence interval [CI], 1.9° to 5.1° across all angular definitions; p < 0.0001) and inclination (1.4°; 95% CI, 0.6° to 2.3° for anatomic angular definition; p < 0.002) was observed. Intrapatient asymmetry in anatomic measures showed bilateral differences in anteversion (maximum, 12.1°) and in inclination (maximum, 10.9°). Significant differences in acetabular orientation between the sexes can be detected only with accurate measurements that account for the entire acetabulum. While a wide range of interpatient acetabular orientations was observed, the majority of subjects had acetabula that were relatively symmetrical in both inclination and anteversion. A highly accurate and

  19. [Pedicle flap transfer combined with external fixator to treat leg open fracture with soft tissue defect].

    PubMed

    Luo, Zhongchun; Lou, Hua; Jiang, Junwei; Song, Chunlin; Gong, Min; Wang, Yongcai

    2008-08-01

    To investigate the clinical results of treating leg open fracture with soft tissue defect by pedicle flap transfer in combination with external fixator. From May 2004 to June 2007, 12 cases of leg open fracture with soft tissue defect, 9 males and 3 females aged 18-75 years, were treated. Among them, 8 cases were caused by traffic accidents, 2 crush, 1 falling and 1 mechanical accident. According to the Gustilo Classification, there were 2 cases of type II, 5 of type IIIA and 5 of type IIIB. There were 2 cases of upper-tibia fracture, 3 of middle-tibia and 7 of middle-lower. The sizes of soft tissue defect ranged from 5 cm x 3 cm to 22 cm x 10 cm.The sizes of exposed bone ranged from 3 cm x 2 cm to 6 cm x 3 cm. The course of the disease was 1-12 hours. Fracture fixation was reached by external fixators or external fixators and limited internal fixation with Kirschner wire. The wounds with exposed tendons and bones were repaired by ipsilateral local rotation flap, sural neurocutaneous flap and saphenous nerve flap. The size of selected flap ranged from 5 cm x 4 cm to 18 cm x 12 cm. Granulation wounds were repaired by skin grafting or direct suture. All patients were followed up for 6 months to 2 years. All patients survived, among whom 2 with the wound edge infection and 1 with the distal necrosis were cured by changing the dressing, 8 with pin hole infection were treated by taking out the external fixator, 1 with nonunion received fracture healing after bone graft in comminuted fracture of lower tibia, 2 suffered delayed union in middle-lower tibia fracture. The ROM of ankle in 3 cases was mildly poor with surpass-joint fixation, with plantar extension of 0-10 degrees and plantar flexion of 10-30 degrees, while the others had plantar extension of 10-20 degrees and plantar flexion of 30-50 degrees. The method of pedicle flap transfer combined with external fixator is safe and effective for the leg open fracture with soft tissue defect.

  20. Lateral Condyle Fracture of the Humerus in Children Treated with Bioabsorbable Materials

    PubMed Central

    Tercier, Stéphane; Bregou-Bourgeois, Aline; Zambelli, Pierre-Yves

    2013-01-01

    The aim of this study was to compare clinical and radiological outcome of lateral condyle fracture of the elbow in children treated with bioabsorbable or metallic material. From January 2008 to December 2009, 16 children with similar fractures and ages were grouped according to the fixation material used. Children were seen at 3, 6, and 12 months and more than 4 years (mean 51.8 months) postoperatively. The clinical results were compared using the Mayo Elbow Performance Score (MEPS). Radiographic studies of the fractured and opposite elbow were assessed at last follow-up control. Twelve children had a sufficient followup and could be included in the study. Seven could be included in the traditional group and 5 in the bioabsorbable group. At 12 months, the MEPS was 100 for every child in both groups. Asymptomatic bony radiolucent visible tracks and heterotopic ossifications were noted in both groups. There were no significant differences in terms of clinical and radiological outcome between the two groups. The use of bioabsorbable pins or screws is a reasonable alternative to the traditional use of metallic materials for the treatment of lateral condyle fracture of the elbow in children. PMID:24228016

  1. Comprehension and reproducibility of the Judet and Letournel classification

    PubMed Central

    Polesello, Giancarlo Cavalli; Nunes, Marcus Aurelius Araujo; Azuaga, Thiago Leonardi; de Queiroz, Marcelo Cavalheiro; Honda, Emerson Kyoshi; Ono, Nelson Keiske

    2012-01-01

    Objective To evaluate the effectiveness of the method of radiographic interpretation of acetabular fractures, according to the classification of Judet and Letournel, used by a group of residents of Orthopedics at a university hospital. Methods We selected ten orthopedic residents, who were divided into two groups; one group received training in a methodology for the classification of acetabular fractures, which involves transposing the radiographic images to a graphic two-dimensional representation. We classified fifty cases of acetabular fracture on two separate occasions, and determined the intraobserver and interobserver agreement. Result The success rate was 16.2% (10-26%) for the trained group and 22.8% (10-36%) for the untrained group. The mean kappa coefficients for interobserver and intraobserver agreement in the trained group were 0.08 and 0.12, respectively, and for the untrained group, 0.14 and 0.29. Conclusion Training in the method of radiographic interpretation of acetabular fractures was not effective for assisting in the classification of acetabular fractures. Level of evidence I, Testing of previously developed diagnostic criteria on consecutive patients (with universally applied reference "gold" standard). PMID:24453583

  2. Well-fixed acetabular component retention or replacement: the whys and the wherefores.

    PubMed

    Blaha, J David

    2002-06-01

    Occasionally the adult reconstructive surgeon is faced with a well-fixed acetabular component that is associated with an arthroplasty problem that ordinarily would require removal and replacement of the cup. Removal of a well-fixed cup is associated with considerable morbidity in bone loss, particularly in the medial wall of the acetabulum. In such a situation, retention of the cup with exchange only of the polyethylene liner may be possible. As preparation for a prospective study, I informally reviewed my experience of cup retention or replacement in revision total hip arthroplasty. An algorithm for retaining or revising a well-fixed acetabular component is presented here. Copyright 2002, Elsevier Science (USA).

  3. Penile vascular indices in surgically treated and conservatively treated penile fracture: does conventional immediate repair matter?

    PubMed

    Safarinejad, Mohammad Reza; Lashkari, Mohammad Hossein; Babaei, Alireza; Dadkhah, Farid; Kolahi, Ali Asghar

    2012-12-01

    To investigate the impact of immediate surgical repair and conservative treatment of penile fracture (PF) on penile vascular indices. The study includes 146 surgically treated (group 1), and 56 conservatively treated patients (group 2). All of the participants underwent penile duplex Doppler ultrasonography (PDDU), and Doppler parameters including the peak systolic velocity (PSV), end diastolic velocity (EDV), and resistive index (RI) were measured in both corpora at baseline and after intracavernosal injection of 20 μg prostaglandin E1. Univariable and multivariable Cox regression analysis addressed study variables. An increased number of men in group 2 (25.0%) compared with men in group 1 (19.2%) reported ED, but the difference did not reach statistical significance (P=0.06). In patients with ED the mean PSV did not differ significantly between the group 1 (30.1±4.02 cm/s) and group 2 (30.1±4.02 cm/s) (P=0.32). Also, in patients without ED, the mean PSV for group 1 (82.4±24.1 cm/s) subjects did not differ significantly from the means for the group 2 patients (79.4±27.2 cm/s) (P=0.21). Vascular hemodynamics in fractured corpus cavernosum did not differ significantly between two groups (P=0.08). Current method of surgical treatment does not provide better outcome in terms of erectile function and penile vascular hemodynamics.

  4. A novel technique of using a miniature plate in combination with tension band wiring to treat comminuted patellar fractures

    PubMed Central

    Gao, Song; Liu, Xuqiang; Zhang, Fengtian; Gao, Tian; Zhang, Zhihong; Dai, Min

    2018-01-01

    Abstract Traditionally, tension band fixation has been used for treating simple fracture patterns; however, fixation remains a challenge, especially for comminuted fractures. We describe a new method of operation using a combination of a miniature plate with tension band wiring to treat comminuted patellar fractures. The aim of this technique is to transform complicate fractures into simple transverse fractures. As far as we know, no studies using a similar method have been found. The purpose of this study was to assess the effectiveness of a novel technique in which a miniature plate is used in combination with tension band wiring to treat comminuted patellar fractures. Between March 2013 and May 2015, 16 patients with closed, displaced, comminuted fractures of the patella were included in the present study. All subjects underwent fixation using a combination of a miniature plate with a tension band wire. Knee function and patient status were evaluated at 12 months using the Böstman knee score and Lysholm knee scale. The average follow-up period was 15.6 months (range, 12–20 months). At the 12-month follow-up, bone healing was satisfactory in all patients. The average postoperative Lysholm score was 91.6 ± 1.4 (range, 84–97). The average postoperative Böstman scale score was 26.4 ± 0.5 (range, 22–30), thereby indicating excellent results in 4 patients and good results in 12. No patients required reoperation. The results demonstrate that this new technique is an effective and safe treatment option for comminuted patella fractures, as it is associated with good clinical outcomes. PMID:29642160

  5. Interventions for treating proximal humeral fractures in adults.

    PubMed

    Handoll, Helen H G; Brorson, Stig

    2015-11-11

    .Different methods of surgical management were tested in 12 trials. One trial (57 participants) comparing two types of locking plate versus a locking nail for treating two-part surgical neck fractures found some evidence of slightly better function after plate fixation but also of a higher rate of surgically-related complications. One trial (61 participants) comparing a locking plate versus minimally invasive fixation with distally inserted intramedullary K-wires found little difference between the two implants at two years. Compared with hemiarthroplasty, one trial (32 participants) found similar results with locking plate fixation in function and re-operation rates, whereas another trial (30 participants) reported all five re-operations occurred in the tension-band fixation group. One trial (62 participants) found better patient-rated (Quick DASH) and composite shoulder function scores at a minimum of two years follow-up and a lower incidence of re-operation and complications after reverse shoulder arthroplasty (RSA) compared with hemiarthroplasty.No important between-group differences were found in one trial (120 participants) comparing the deltoid-split approach versus deltopectoral approach for non-contact bridging plate fixation, and two trials (180 participants) comparing 'polyaxial' and 'monaxial' screws in locking plate fixation. One trial (68 participants) produced some preliminary evidence that tended to support the use of medial support locking screws in locking plate fixation. One trial (54 participants) found fewer adverse events, including re-operations, for the newer of two types of intramedullary nail. One trial (35 participants) found better functional results for one of two types of hemiarthroplasty. One trial (45 participants) found no important effects of tenodesis of the long head of the biceps for people undergoing hemiarthroplasty.Very limited evidence suggested similar outcomes from early versus later mobilisation after either surgical fixation (one trial

  6. Conservative interventions for treating middle third clavicle fractures in adolescents and adults.

    PubMed

    Lenza, Mário; Faloppa, Flávio

    2016-12-15

    Clavicle (collarbone) fractures account for around 4% of all fractures. Most (76%) clavicle fractures involve the middle-third section of the clavicle. Treatment of these fractures is usually non-surgical (conservative). Commonly used treatments are arm slings, strapping and figure-of-eight bandages.This is an update of a Cochrane review first published in 2009 and updated in 2014. To evaluate the effects (benefits and harms) of different methods for conservative (non-operative) treatment for acute (treated soon after injury) middle third clavicle fractures in adolescents and adults. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register, the Cochrane Central Register of Controlled Trials, MEDLINE (from 1966), Embase (from 1980), LILACS (from 1982), trial registers, orthopaedic proceedings and reference lists of articles. We applied no language or publication restrictions. The date of the last search was 5 January 2016. Randomised and quasi-randomised controlled trials testing conservative interventions for treating adolescents and adults with acute middle third clavicle fractures. The primary outcomes were shoulder function or disability, pain and treatment failure. For this update, two review authors selected eligible trials, independently assessed risk of bias and cross-checked data extraction. We calculated risk ratios and 95% confidence intervals for dichotomous variables, and mean differences and 95% confidence intervals for continuous variables. There was very limited pooling of data. We included four trials in this review with 416 participants, who were aged 14 years or above. One new trial was included in this update.Very low quality evidence was available from three trials (296 participants) that compared the figure-of-eight bandage with an arm sling for treating acute middle third clavicle fractures. The three trials were underpowered and compromised by poor methodology. Shoulder function was assessed in different ways in the

  7. A new method for the measurement of anteversion of the acetabular cup after total hip arthroplasty.

    PubMed

    Aydogan, Mehmet; Burç, Halil; Saka, Gursel

    2014-08-01

    Many methods of determining the anteversion of the acetabular cup have been described in the literature. The advantages and disadvantages of each of these methods are discussed in this paper. We present a new method of measuring the acetabular anteversion at the anteroposterior hip. The formula designed by the authors was anteversion angle (α) = arc sin |PK|/√ |AK| × |BK|. The formula was tested using the AutoCAD software, and an experimental study was conducted to evaluate the accuracy. Three groups were created, and 16 X-ray images were taken and coded. Ten orthopaedic surgeons measured the acetabular anteversion from these X-rays using our formula. The results in Group 1 were closer to the actual value; in contrast, the results in Group 2 differed from the actual values. The results in Group 3 were as close to the actual anteversion values as were those in Group 1. Developments in technology often bring an increase in complications. Despite newly developed surgical methods and technology, the position of the acetabular cup is still used to determine the results of a total hip arthroplasty. Our method is simple, cost-effective and achieves almost 100 % accuracy.

  8. Horizontal root fracture treated with MTA, a case report with a 10-year follow-up.

    PubMed

    Roig, Miguel; Espona, José; Mercadé, Montse; Duran-Sindreu, Fernando

    2011-12-01

    Root fractures occur more frequently in fully erupted permanent teeth with closed apices in which the completely formed root is solidly supported in the bone and periodontium. The consequences can be complex because of combined damage to the pulp, dentine, cementum, bone, and periodontium. Management of horizontal root fractures and lateral luxation depends on several factors, with the result that various clinical modalities have been suggested. This case report describes the treatment and 10-year follow-up of two maxillary central incisors, one with horizontal root fracture and the other with lateral luxation, treated with mineral trioxide aggregate and root canal treatment, respectively. © 2011 John Wiley & Sons A/S.

  9. The effect of canal fill on paediatric femur fractures treated with titanium elastic nails.

    PubMed

    Nielsen, E; Bonsu, N; Andras, L M; Goldstein, R Y

    2018-02-01

    Traditional teaching for fixation of paediatric femur fractures recommends 80% nail diameter/medullary canal diameter ratio (ND/MCD) for successful maintenance of reduction. Prior studies have investigated this with stainless steel Enders nails. Our aim was to assess the impact of ND/MCD on maintenance of reduction and malunion rates in paediatric femur fractures treated with flexible intramedullary nails (FINs). Retrospective data was collected on all paediatric patients treated with FINs for diaphyseal femur fractures at a single tertiary care institution over a ten-year period. Patients with co-morbidities affecting bone quality were excluded. Patients were subdivided into groups based on ND/MCD. A total of 66 patients met inclusion criteria. Mean ND/MCD was 76.3% (32.9% to 98.8%, SD 14.3). In all, 50% (n = 33/66) of patients had > 80% ND/MCD, and only 13.6% (n = 9/66) of patients had less than 60% ND/MCD. When controlling for fracture stability, ND/MCD had no correlation with mean shortening (p = 0.07) There was no correlation between ND/MCD and angulation in the sagittal (p = 0.96) or coronal plane (p = 0.20). Three patients fit malunion criteria. ND/MCD for these patients were 40%, 67% and 79%. There was no correlation between ND/MCD and shortening or malangulation. The majority of patients in this series with less than 80% fill with FIN healed within acceptable parameters. III.

  10. An In Vitro Study on the Effects of Post-Core Design and Ferrule on the Fracture Resistance of Endodontically Treated Maxillary Central Incisors.

    PubMed

    Sreedevi, S; Sanjeev, R; Raghavan, Rekha; Abraham, Anna; Rajamani, T; Govind, Girish Kumar

    2015-08-01

    Endodontically treated teeth have significantly different physical and mechanical properties compared to vital teeth and are more prone to fracture. The study aims to compare the fracture resistance of endodontically treated teeth with and without post reinforcement, custom cast post-core and prefabricated post with glass ionomer core and to evaluate the ferrule effect on endodontically treated teeth restored with custom cast post-core. A total of 40 human maxillary central incisors with similar dimensions devoid of any root caries, restorations, previous endodontic treatment or cracks were selected from a collection of stored extracted teeth. An initial silicone index of each tooth was made. They were treated endodontically and divided into four groups of ten specimens each. Their apical seal was maintained with 4 mm of gutta-percha. Root canal preparation was done and then post core fabrication was done. The prepared specimens were subjected to load testing using a computer coordinated UTM. The fracture load results were then statistically analyzed. One-way ANOVA was followed by paired t-test. 1. Reinforcement of endodontically treated maxillary central incisors with post and core, improved their fracture resistance to be at par with that of endodontically treated maxillary central incisor, with natural crown. 2. The fracture resistance of endodontically treated maxillary central incisors is significantly increased when restored with custom cast post-core and 2 mm ferrule. With 2 mm ferrule, teeth restored with custom cast post-core had a significantly higher fracture resistance than teeth restored with custom cast post-core or prefabricated post and glass ionomer core without ferrule.

  11. Cost-effectiveness of training rural providers to identify and treat patients at risk for fragility fractures.

    PubMed

    Nelson, S D; Nelson, R E; Cannon, G W; Lawrence, P; Battistone, M J; Grotzke, M; Rosenblum, Y; LaFleur, J

    2014-12-01

    This is a cost-effectiveness analysis of training rural providers to identify and treat osteoporosis. Results showed a slight cost savings, increase in life years, increase in treatment rates, and decrease in fracture incidence. However, the results were sensitive to small differences in effectiveness, being cost-effective in 70 % of simulations during probabilistic sensitivity analysis. We evaluated the cost-effectiveness of training rural providers to identify and treat veterans at risk for fragility fractures relative to referring these patients to an urban medical center for specialist care. The model evaluated the impact of training on patient life years, quality-adjusted life years (QALYs), treatment rates, fracture incidence, and costs from the perspective of the Department of Veterans Affairs. We constructed a Markov microsimulation model to compare costs and outcomes of a hypothetical cohort of veterans seen by rural providers. Parameter estimates were derived from previously published studies, and we conducted one-way and probabilistic sensitivity analyses on the parameter inputs. Base-case analysis showed that training resulted in no additional costs and an extra 0.083 life years (0.054 QALYs). Our model projected that as a result of training, more patients with osteoporosis would receive treatment (81.3 vs. 12.2 %), and all patients would have a lower incidence of fractures per 1,000 patient years (hip, 1.628 vs. 1.913; clinical vertebral, 0.566 vs. 1.037) when seen by a trained provider compared to an untrained provider. Results remained consistent in one-way sensitivity analysis and in probabilistic sensitivity analyses, training rural providers was cost-effective (less than $50,000/QALY) in 70 % of the simulations. Training rural providers to identify and treat veterans at risk for fragility fractures has a potential to be cost-effective, but the results are sensitive to small differences in effectiveness. It appears that provider education alone is

  12. [Missed diagnosis of osteoporosis and failure to treat adults with hip fracture in Chile].

    PubMed

    Rodríguez, José Adolfo; Borzutzky, Arturo; Barnett, Carolina; Marín, Pedro Paulo

    2003-07-01

    Hip fractures are the most severe complication of osteoporosis, yet patients who suffer hip fracture rarely receive adequate treatment. To assess diagnosis and treatment of osteoporosis in patients with hip fracture. A retrospective study in 203 patients admitted for hip fracture surgery at two medical institutions in Santiago, Chile. Clinical data from 101 patients from the Hospital Clínico Pontificia Universidad Católica de Chile (a university tertiary care hospital, HCPUC) and 102 patients from Hospital de Urgencia de la Asistencia Pública (a public emergency hospital, HUAP) were reviewed. We also evaluated incidence of new fractures, further treatment of osteoporosis and functionality, by means of a telephonic survey of 48% of patients (n = 99) 12.3 +/- 5.3 months after hip fracture in HCPUC and 16.5 +/- 3.0 months for HUAP. A previous diagnosis of osteoporosis was present in 2.9% and 1% of cases, and treatment prior to fracture in 3.9% and 0% of cases from HCPUC and HUAP, respectively. None of the patients in HUAP were diagnosed with osteoporosis during hospital stay or given treatment for this condition at discharge, in comparison to 0.9% (n = 1) and 2% (n = 2), respectively, in HCPUC. Seven and six percent of cases presented prior hip fractures. Telephonic follow up of patients revealed that 75.6% persisted without treatment for osteoporosis. At follow up, 2.9% and 3% of patients in HCPUC and HUAP had presented new hip fractures. At the time of survey 30.9% and 34% of patients, respectively, were considered invalid. Missed diagnosis and failure to treat osteoporosis occurred in over 90% of patients admitted for hip fracture, regardless of the different complexities in the hospitals of admission. The data suggest that lack of medical action on these issues may play a role in failure to prevent new hip fractures.

  13. The use of customized cages in revision total hip arthroplasty for Paprosky type III acetabular bone defects.

    PubMed

    Mao, Yuanqing; Xu, Chen; Xu, Jiawei; Li, Huiwu; Liu, Fengxiang; Yu, Degang; Zhu, Zhenan

    2015-10-01

    Revision total hip arthroplasty (THA) is challenging if severe periacetabular bone loss is present. Here we describe a method that uses a customised cage to reconstruct an acetabulum with a massive bone defect. Designed with the aid of the rapid prototyping technique, a customised cage with a hook, crest and flange or braids was made, and then utilized to reconstruct severe compromised acetabulum in revision THA since 2001. Twenty-two patients (23 hips) were included in this study. The mean patient age at the time of surgery was 60.9 years (range, 38-80 years). Three hips had massive acetabular bone defects of Paprosky type IIIA and 20 of type IIIB. The Harris hip score was used to evaluate hip function. Radiographs were taken to evaluate loosening of the cage and resorption of allograft bone. The average follow up was 81.6 ± 24.9 months. The mean Harris hip score improved from 39.6 pre-operatively to 80.9 at the final follow-up. There were no instances of deep infection, severe venous thrombosis, and nerve palsy. One patient who had an intra-operative rupture of the superior acetabular artery was successfully treated using the haemostatic suturing technique. Two patients experienced dislocation at post-operative days four and six, respectively, and both were treated with closed reduction and skin traction for three weeks. The present study demonstrates that a customised cage may be a promising option for THA revision of severely compromised acetabula. Extended follow-up is necessary to evaluate the long-term performance of this approach.

  14. Acetabular Global Insufficiency in Patients with Down Syndrome and Hip-Related Symptoms: A Matched-Cohort Study.

    PubMed

    Bulat, Evgeny; Maranho, Daniel A; Kalish, Leslie A; Millis, Michael B; Kim, Young-Jo; Novais, Eduardo N

    2017-10-18

    The etiology of hip instability in Down syndrome is not completely understood. We investigated the morphology of the acetabulum and femur in patients with Down syndrome and compared measurements of the hips with those of matched controls. Computed tomography (CT) images of the pelvis of 42 patients with Down syndrome and hip symptoms were compared with those of 42 age and sex-matched subjects without Down syndrome or history of hip disease who had undergone CT for abdominal pain. Each of the cohorts had 23 male and 19 female subjects. The mean age (and standard deviation) in each cohort was 11.3 ± 5.3 years. The lateral center-edge angle (LCEA), acetabular inclination angle (IA), acetabular depth-width ratio (ADR), acetabular version, and anterior and posterior acetabular sector angles (AASA and PASA) were compared. The neck-shaft angle and femoral version were measured in the patients with Down syndrome only. The hips of the patients with Down syndrome were further categorized as stable (n = 21) or unstable (n = 63) for secondary analysis. The hips in the Down syndrome group had a smaller LCEA (mean, 10.8° ± 12.6° compared with 25.6° ± 4.6°; p < 0.0001), a larger IA (mean, 17.4° ± 10.3° compared with 10.9° ± 4.8°; p < 0.0001), a lower ADR (mean, 231.9 ± 56.2 compared with 306.8 ± 31.0; p < 0.0001), a more retroverted acetabulum (mean acetabular version as measured at the level of the centers of the femoral heads [AVC], 7.8° ± 5.1° compared with 14.0° ± 4.5°; p < 0.0001), a smaller AASA (mean, 55.0° ± 9.9° compared with 59.7° ± 7.8°; p = 0.005), and a smaller PASA (mean, 67.1° ± 10.4° compared with 85.2° ± 6.8°; p < 0.0001). Within the Down syndrome cohort, the unstable hips showed greater femoral anteversion (mean, 32.7° ± 14.6° compared with 23.6° ± 10.6°; p = 0.002) and worse global acetabular insufficiency compared with the stable hips. No differences between the unstable and stable hips were found with respect to

  15. Surface-enhanced Raman scattering study of the healing of radial fractures treated with or without Huo-Xue-Hua-Yu decoction therapy

    NASA Astrophysics Data System (ADS)

    Chen, Weiwei; Huang, Hao; Chen, Rong; Feng, Shangyuan; Yu, Yun; Lin, Duo; Lin, Jia

    2014-11-01

    This study aimed to assess, through surface-enhanced Raman scattering (SERS) spectroscopy, the incorporation of calcium hydroxyapatite (CHA ~960 cm-1) and other biochemical substances in the repair of complete radial fractures in rabbits treated with or without Huo-Xue-Hua-Yu decoction (HXHYD) therapy. A total of 18 rabbits with complete radial fractures were randomly divided into two groups; one group was treated with HXHYD therapy and the other without therapy acted as a control. The animals were sacrificed at 15, 30 and 45 d after surgery. Specimens were routinely prepared for SERS measurement and high quality SERS spectra from a mixture of bone tissues and silver nanoparticles were obtained. The mineral-to-matrix ratios from the control and treated groups were calculated. Results showed that both deposition content of CHA measured by SERS spectroscopy and the mineral-to-matrix ratio in the treated group were always greater than those of the control group during the experiment, demonstrating that HXHYD therapy is effective in improving fracture healing and that SERS spectroscopy might be a novel tool to assess fracture healing.

  16. Female Sex Is a Risk Factor for Failure of Hip Arthroscopy Performed for Acetabular Retroversion

    PubMed Central

    Poehling-Monaghan, Kirsten L.; Krych, Aaron J.; Levy, Bruce A.; Trousdale, Robert T.; Sierra, Rafael J.

    2017-01-01

    Background: The success of hip surgery in treating acetabular retroversion depends on the severity of the structural deformity and on selecting the correct patient for open or arthroscopic procedures. Purpose: To compare a group of patients with retroverted hips treated successfully with hip arthroscopy with a group of patients with retroverted hips that failed arthroscopic surgery, with special emphasis on (1) patient characteristics, (2) perioperative radiographic parameters, (3) intraoperative findings and concomitant procedures, and (4) patient sex. Study Design: Case-control study; Level of evidence, 3. Methods: We retrospectively reviewed the charts of 47 adult patients (47 hips) with acetabular retroversion who had undergone hip arthroscopy. Retroversion was based on the presence of an ischial spine sign in addition to either a crossover or posterior wall sign on a well-positioned anteroposterior pelvic radiograph. A total of 24 hips (50%) (16 females, 8 males; mean patient age, 31 years) had failed arthroscopy, defined as modified Harris Hip Score (mHHS) <80 or need for subsequent procedure. Twenty-three hips (8 females, 15 males; mean patient age, 29 years) were considered successful, defined as having no subsequent procedures and an mHHS >80 at the time of most recent follow-up. Perioperative variables, radiographic characteristics, and intraoperative findings were compared between the groups, in addition to a subgroup analysis based on sex. Results: The mean follow-up for successful hips was 30 months (SD, 11 months), with a mean mHHS of 95. In the failure group, 6 patients required subsequent procedures (4 anteverting periacetabular osteotomies and 2 total hip arthroplasties). The mean overall time to failure was 21 months, and the mean time to a second procedure was 24 months (total hip arthroplasty, 29.5 months; periacetabular osteotomy, 21.2 months); 18 hips failed on the basis of a low mHHS (mean, 65; range, 27-79) at last follow-up. Factors

  17. Morphometric analysis of acetabular dysplasia in cerebral palsy: three-dimensional CT study.

    PubMed

    Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2009-12-01

    Three-dimensional computed tomography (3D-CT) eliminates the positioning errors and allows the clinician to more accurately assess the radiographic parameters present. To elucidate the 3D geometry of the acetabulum and the extent of hip subluxation/dislocation in patients with cerebral palsy (CP), quantitative morphometric analysis was performed using 3D-CT data. We evaluated 150 hips in 75 patients with bilateral spastic CP. The mean age of the patients was 5.4 years (range: 2.7 to 6.9 y). The fitting plane of the ilium was projected onto the coronal plane and then onto the sagittal plane, and then the angle formed with a horizontal line was defined as CTalpha (the lateral opening angle) and CTbeta (the sagittal inclination angle), respectively. The center of the acetabulum and the femoral head were defined, and the distance between these centers was divided by the femoral head diameter, defined as CT migration percentage (CTMP, %). In 123 (82%) of the 150 hips, the femoral head center was located posteriorly, superiorly, and laterally relative to the acetabular center. Large CTalpha cases tended to show large CTMP. CTalpha and CTMP were significantly larger in the cases with Gross Motor Functional Classification System (GMFCS) level IV/V and spastic quadriplegia, than in the cases with GMFCS level II/III and spastic diplegia. CTbeta showed significant correlation with the acetabular defect on the lateral 3D reconstructed images. Three-dimensional acetabular geometry and migration percentage in CP patients can be analyzed quantitatively using 3D-CT regardless of the abnormal spastic posture. The extent of acetabular dysplasia and subluxation is more severe in patients with GMFCS level IV/V and spastic quadriplesia. Level 4.

  18. The Bimetric cementless total hip replacement: 7-18 year follow-up assessing the influence of acetabular design on survivorship.

    PubMed

    Russell, R C; Ghassemi, A; Dorrell, J H; Powles, D P

    2009-08-01

    The purpose of this study was to evaluate the mid- to long-term survivorship of Bimetric cementless total hip replacement and assess how it is affected by the acetabular design. This was a retrospective analysis of 127 Bimetric cementless total hip replacements in 110 patients with a follow-up of 7-18 years. A single design stem and three different cementless metal-backed acetabular designs were used. Patients were assessed clinically using the Harris hip score and radiologically by independent review of current hip radiographs. There was only one case of aseptic loosening of the femoral stem. The earliest acetabular design showed a high failure rate whilst the latter two designs showed a 96% survivorship at a mean of 9.5 years. We conclude that a combination of the bimetric stem with either of the latter acetabular cup designs has a good mid- to long-term performance.

  19. Radiological and functional outcomes 2.7 years following conservatively treated completely displaced midshaft clavicle fractures.

    PubMed

    Fuglesang, Hendrik F S; Flugsrud, Gunnar B; Randsborg, Per-Henrik; Stavem, Knut; Utvåg, Stein E

    2016-01-01

    It is unclear whether all completely displaced midshaft clavicle fractures require primary surgical intervention. The aim of this study was to elucidate the radiological and clinical outcomes after conservative treatment, and to identify subgroups at risk of an inferior outcome. Retrospective case series. Level II trauma center. Between 2005 and 2008, 122 patients were conservatively treated for a completely displaced midshaft clavicle fracture of whom 92 were eligible for inclusion in this study. Of these, 59 completed the study after a median of 2.7 years after the fracture (min-max, 1.1-4.9). The patients received the standard treatment administered at our institution at the time: nonsurgically with a sling without physiotherapy. Patients with painful nonunions were subsequently offered surgery. At follow-up, the patients' Disabilities of Arm, Shoulder, and Hand (DASH) and the Constant scores were evaluated. Radiographs were taken at follow-up and compared to those taken acutely. Nonunion was found in 9 of the 59 (15.3%) patients. Twenty-four (24%) patients reported a fair-to-poor DASH score (i.e. >20). Patients with fractures that were vertically displaced by more than 100% (one bone width) were significantly less satisfied than those with fractures vertically displaced at 100% (p = 0.04). Initial shortening of more than 15 mm was not associated with a worse outcome or nonunion. The odds ratio of developing a nonunion increased with age (p = 0.04). By treating completely displaced midshaft clavicle fractures conservatively with a sling and offering plate fixation for eventual painful nonunions, we found a 24% risk of a fair or poor clinical result with a DASH score over 20. A vertical displacement of more than 100 % between the main fragments on the initial radiograph was associated with an inferior clinical outcome in this study. IV.

  20. An in vitro Evaluation of Fracture Resistance of endodontically treated Teeth with Different Restorative Materials.

    PubMed

    Sangwan, Babita; Rishi, Rahul; Seal, Mukut; Jain, Kanav; Dutt, Pranjali; Talukdar, Pratim

    2016-07-01

    The aim of the present study is to compare and assess the fracture resistance of root canal treated teeth with different restorative materials. The present in vitro study was carried out on seventy-five freshly extracted, noncarious, single-canal human lower-first premolars with similar anatomic characteristics. Teeth were randomly assigned to five groups with 15 teeth being present in each group. Group I is control group (no alteration done), group II is restored with silver amalgam after endodontic therapy, group III is restored with posterior composite after end-odontic therapy, group IV is restored with posterior glass ionomer cement (GIC) after endodontic therapy, and group V is restored with miracle mix after endodontic therapy. Universal testing machine was used to assess the fracture strength. Analysis of variance (ANOVA) test followed by Tukey's post hoc test were used to determine the significant difference between each group. A p-value of < 0.05 was considered as statistically significant. The mean fracture resistance of control group showed highest fracture resistance with a mean Newton of 1083.33 ± 136.78. Among the restorative material, the highest fracture resistance was shown by teeth restored by composite (845.46 ± 47.36), followed by silver amalgam (845.46 ± 47.36). There was statistically significant difference among all the restorative materials compared with the control group (p < 0.05). However, among the teeth restored with silver amalgam and miracle mix, there was no statistical significance (p > 0.05). The present study concludes that composites are found to be having more fracture resistance followed by silver amalgam on endodontically treated premolar teeth. Restoring nonvital teeth represents a major challenge for clinicians as they are extensively damaged due to caries and endodontic access preparations. With various restorative materials in the market, it becomes difficult for the clinician to choose the better restorative material

  1. Accuracy of templating the acetabular cup size in Total Hip Replacement using conventional acetate templates on digital radiographs.

    PubMed

    Krishnamoorthy, Vignesh P; Perumal, Rajamani; Daniel, Alfred J; Poonnoose, Pradeep M

    2015-12-01

    Templating of the acetabular cup size in Total Hip Replacement (THR) is normally done using conventional radiographs. As these are being replaced by digital radiographs, it has become essential to create a technique of templating using digital films. We describe a technique that involves templating the digital films using the universally available acetate templates for THR without the use of special software. Preoperative digital radiographs of the pelvis were taken with a 30 mm diameter spherical metal ball strapped over the greater trochanter. Using standard acetate templates provided by the implant company on magnified digital radiographs, the size of the metal ball (X mm) and acetabular cup (Y mm) were determined. The size of the acetabular cup to be implanted was estimated using the formula 30*Y/X. The estimated size was compared with the actual size of the cup used at surgery. Using this technique, it was possible to accurately predict the acetabular cup size in 28/40 (70%) of the hips. When the accuracy to within one size was considered, templating was correct in 90% (36/40). When assessed by two independent observers, there was good intra-observer and inter-observer reliability with intra-class correlation coefficient values greater than 0.8. It was possible to accurately and reliably predict the size of the acetabular cup, using acetate templates on digital films, without any digital templates.

  2. Pneumothorax complicating isolated clavicle fracture

    PubMed Central

    Hani, Redouane; Ennaciri, Badr; Jeddi, Idriss; El Bardouni, Ahmed; Mahfoud, Mustapha; Berrada, Mohamed Saleh

    2015-01-01

    Isolated clavicle fractures are among the commonest of traumatic fractures in the emergency department. Complications of isolated clavicle fractures are rare. Pneumothorax has been described as a complication of a fractured clavicle only rarely in English literature. In all the reported cases, the pneumothorax was treated by a thoracostomy and the clavicle fracture was treated conservatively. In our case, the pneumothorax required a chest drain insertion and the clavicle fracture was treated surgically with good result. PMID:26421097

  3. Pneumothorax complicating isolated clavicle fracture.

    PubMed

    Hani, Redouane; Ennaciri, Badr; Jeddi, Idriss; El Bardouni, Ahmed; Mahfoud, Mustapha; Berrada, Mohamed Saleh

    2015-01-01

    Isolated clavicle fractures are among the commonest of traumatic fractures in the emergency department. Complications of isolated clavicle fractures are rare. Pneumothorax has been described as a complication of a fractured clavicle only rarely in English literature. In all the reported cases, the pneumothorax was treated by a thoracostomy and the clavicle fracture was treated conservatively. In our case, the pneumothorax required a chest drain insertion and the clavicle fracture was treated surgically with good result.

  4. Fracture resistance of endodontically treated molars restored with horizontal fiberglass posts or indirect techniques.

    PubMed

    Bromberg, Carolina Ritter; Alves, Caroline Beatriz; Stona, Deborah; Spohr, Ana Maria; Rodrigues-Junior, Sinval Adalberto; Melara, Rafael; Burnett, Luiz Henrique

    2016-12-01

    Because of the many possibilities for endodontically restoring the posterior teeth and the high prevalence of restoration failures, this topic continues to be of major concern. A composite resin (CR) restoration reinforced by a horizontal fiberglass post may improve the fracture resistance of endodontically treated teeth. The authors investigated this possibility by comparing the fracture resistance of molars restored with direct techniques with that of molars restored with indirect techniques. The authors divided 50 extracted sound third molars into 5 groups: sound teeth, onlay (ON), inlay (IN), direct CR, and transfixed fiberglass post (TFP) plus direct CR. The authors performed standardized mesio-occlusodistal cavity preparations and endodontic treatments. The authors cemented indirect restorations of Lava Ultimate (3M ESPE) adhesively in the ON and IN groups. The authors restored CR group teeth directly with Filtek Z230 XT (3M ESPE). In the TFP group, the authors transfixed 2 fiberglass posts horizontally and restored the teeth directly with CR. Thereafter, the authors submitted the teeth to cyclic fatigue loading with 500,000 cycles at 200 newtons. The authors tested fracture resistance in newtons in a universal testing machine. The authors analyzed data with 1-way analysis of variance and a Tukey test (P < .05). Sound teeth had the highest fracture resistance. ON had the highest recovery of resistance, followed by TFP. CR had the lowest recovery, which was similar to that of IN. Endodontically treated molars restored with TFP plus CR had fracture resistance similar to those restored with ON, which was higher than that for IN or CR only. Horizontal TFPs placed inside a composite restoration had the same performance as did ON restorations. Copyright © 2016 American Dental Association. Published by Elsevier Inc. All rights reserved.

  5. Validation of a 3D CT method for measurement of linear wear of acetabular cups.

    PubMed

    Jedenmalm, Anneli; Nilsson, Fritjof; Noz, Marilyn E; Green, Douglas D; Gedde, Ulf W; Clarke, Ian C; Stark, Andreas; Maguire, Gerald Q; Zeleznik, Michael P; Olivecrona, Henrik

    2011-02-01

    We evaluated the accuracy and repeatability of a 3D method for polyethylene acetabular cup wear measurements using computed tomography (CT). We propose that the method be used for clinical in vivo assessment of wear in acetabular cups. Ultra-high molecular weight polyethylene cups with a titanium mesh molded on the outside were subjected to wear using a hip simulator. Before and after wear, they were (1) imaged with a CT scanner using a phantom model device, (2) measured using a coordinate measurement machine (CMM), and (3) weighed. CMM was used as the reference method for measurement of femoral head penetration into the cup and for comparison with CT, and gravimetric measurements were used as a reference for both CT and CMM. Femoral head penetration and wear vector angle were studied. The head diameters were also measured with both CMM and CT. The repeatability of the method proposed was evaluated with two repeated measurements using different positions of the phantom in the CT scanner. The accuracy of the 3D CT method for evaluation of linear wear was 0.51 mm and the repeatability was 0.39 mm. Repeatability for wear vector angle was 17°. This study of metal-meshed hip-simulated acetabular cups shows that CT has the capacity for reliable measurement of linear wear of acetabular cups at a clinically relevant level of accuracy.

  6. Acoustic Emission Methodology to Evaluate the Fracture Toughness in Heat Treated AISI D2 Tool Steel

    NASA Astrophysics Data System (ADS)

    Mostafavi, Sajad; Fotouhi, Mohamad; Motasemi, Abed; Ahmadi, Mehdi; Sindi, Cevat Teymuri

    2012-10-01

    In this article, fracture toughness behavior of tool steel was investigated using Acoustic Emission (AE) monitoring. Fracture toughness ( K IC) values of a specific tool steel was determined by applying various approaches based on conventional AE parameters, such as Acoustic Emission Cumulative Count (AECC), Acoustic Emission Energy Rate (AEER), and the combination of mechanical characteristics and AE information called sentry function. The critical fracture toughness values during crack propagation were achieved by means of relationship between the integral of the sentry function and cumulative fracture toughness (KICUM). Specimens were selected from AISI D2 cold-work tool steel and were heat treated at four different tempering conditions (300, 450, 525, and 575 °C). The results achieved through AE approaches were then compared with a methodology proposed by compact specimen testing according to ASTM standard E399. It was concluded that AE information was an efficient method to investigate fracture characteristics.

  7. Postural correction reduces hip pain in adult with acetabular dysplasia: A case report.

    PubMed

    Lewis, Cara L; Khuu, Anne; Marinko, Lee N

    2015-06-01

    Developmental dysplasia of the hip is often diagnosed in infancy, but less severe cases of acetabular dysplasia are being detected in young active adults. The purpose of this case report is to present a non-surgical intervention for a 31-year-old female with mild acetabular dysplasia and an anterior acetabular labral tear. The patient presented with right anterior hip and groin pain, and she stood with the trunk swayed posterior to the pelvis (swayback posture). The hip pain was reproduced with the anterior impingement test. During gait, the patient maintained the swayback posture and reported 6/10 hip pain. Following correction of the patient's posture, the patient's pain rating was reduced to a 2/10 while walking. The patient was instructed to maintain the improved posture. At the 1 year follow-up, she demonstrated significantly improved posture in standing and walking. She had returned to recreational running and was generally pain-free. The patient demonstrated improvement on self-reported questionnaires for pain, function, and activity. These findings suggest that alteration of posture can have an immediate and lasting effect on hip pain in persons with structural abnormality and labral pathology. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Postural correction reduces hip pain in adult with acetabular dysplasia: a case report

    PubMed Central

    Lewis, Cara L.; Khuu, Anne; Marinko, Lee

    2015-01-01

    Developmental dysplasia of the hip is often diagnosed in infancy, but less severe cases of acetabular dysplasia are being detected in young active adults. The purpose of this case report is to present a non-surgical intervention for a 31-year-old female with mild acetabular dysplasia and an anterior acetabular labral tear. The patient presented with right anterior hip and groin pain, and she stood with the trunk swayed posterior to the pelvis (swayback posture). The hip pain was reproduced with the anterior impingement test. During gait, the patient maintained the swayback posture and reported 6/10 hip pain. Following correction of the patient’s posture, the patient’s pain rating was reduced to a 2/10 while walking. The patient was instructed to maintain the improved posture. At the 1 year follow-up, she demonstrated significantly improved posture in standing and walking. She had returned to recreational running and was generally pain-free. The patient demonstrated improvement on self-reported questionnaires for pain, function and activity. These findings suggest that alteration of posture can have an immediate and lasting effect on hip pain in persons with structural abnormality and labral pathology. PMID:25731688

  9. Robotic-arm assisted total hip arthroplasty results in smaller acetabular cup size in relation to the femoral head size: a matched-pair controlled study.

    PubMed

    Suarez-Ahedo, Carlos; Gui, Chengcheng; Martin, Timothy J; Chandrasekaran, Sivashankar; Lodhia, Parth; Domb, Benjamin G

    2017-03-31

    To compare the acetabular component size relative to the patient's native femoral head size between conventional THA (CTHA) approach and robotic-arm assisted THA (RTHA) to infer which of these techniques preserved more acetabular bone. Patients were included if they had primary osteoarthritis (OA) and underwent total hip replacement between June 2008 and March 2014. Patients were excluded if they had missing or rotated postoperative anteroposterior radiographs. RTHA patients were matched to a control group of CTHA patients, in terms of preoperative native femoral head size, age, gender, body mass index (BMI) and approach. Acetabular cup size relative to femoral head size was used as a surrogate for amount of bone resected. We compared the groups according to 2 measures describing acetabular cup diameter (c) in relation to femoral head diameter (f): (i) c-f, the difference between cup diameter and femoral head diameter and (ii) (c-f)/f, the same difference as a fraction of femoral head diameter. 57 matched pairs were included in each group. There were no significant differences between groups for demographic measures, femoral head diameter, or acetabular cup diameter (p>0.05). However, measures (i) and (ii) did differ significantly between the groups, with lower values in the RTHA group (p<0.02). Using acetabular cup size relative to femoral head size as an approximate surrogate measure of acetabular bone resection may suggest greater preservation of bone stock using RTHA compared to CTHA. Further studies are needed to validate the relationship between acetabular cup size and bone loss in THA.

  10. The societal costs of femoral neck fracture patients treated with internal fixation.

    PubMed

    Zielinski, S M; Bouwmans, C A M; Heetveld, M J; Bhandari, M; Patka, P; Van Lieshout, E M M

    2014-03-01

    The study rationale was to provide a detailed overview of the costs for femoral neck fracture treatment with internal fixation in the Netherlands. Mean total costs per patient at 2-years follow-up were 19,425. Costs were higher for older, less healthy patients. Results are comparable to internationally published costs. The aim of this study was to provide a detailed overview of the cost and healthcare consumption of patients treated for a hip fracture with internal fixation. A secondary aim was to compare costs of patients who underwent a revision surgery with patients who did not. The study was performed alongside the Dutch sample of an international randomized controlled trial, concerning femoral neck fracture patients treated with internal fixation. Patient characteristics and healthcare consumption were collected. Total follow-up was 2 years. A societal perspective was adopted. Costs included hospital costs during primary stay and follow-up, and costs related to rehabilitation and changes in living situation. Costs were compared between non-revision surgery patients, implant removal patients, and revision arthroplasty patients. A total of 248 patients were included (mean age 71 years). Mean total costs per patient at 2-years follow-up were 19,425. In the non-revision surgery patients total costs were 17,405 (N = 137), in the implant removal patients 10,066 (N = 38), and in the revision arthroplasty patients 26,733 (N = 67). The main contributing costs were related to the primary surgery, admission days, physical therapy, and revision surgeries. The main determinant was the costs of admission to a rehabilitation center/nursing home. Costs were specifically high in elderly with comorbidity, who were less independent pre-fracture, and have a longer admission to the hospital and/or a nursing home. Costs were also higher in revision surgery patients. The 2-years follow-up costs in our study were comparable to published costs

  11. Predictors for perioperative blood transfusion in elderly patients with extra capsular hip fractures treated with cephalo-medullary nailing.

    PubMed

    Fazal, M Ali; Bagley, Caroline; Garg, Parag

    2018-02-01

    The aim of our study was to determine predictive factors and requirement for perioperative blood transfusion in elderly patients with extra capsular hip fractures treated with cephalo-medullary device. Seventy-nine patients with extra capsular hip fractures treated with cephalo-medullary nailing were included in the study. Age, sex, ASA grade, timing of surgery, preoperative and postoperative haemoglobin, length of hospital stay, fracture type, number of units transfused and 30-day mortality were recorded. The mean age was 82.3 years. Forty-seven patients underwent a short nail and 32 patients a long nail; 53.4% patients required blood transfusion postoperatively. Transfusion was required in 71.8% of the long nails (p < 0.05), 65.8% patients above the age of 80 (p < 0.05), 100% of the patients with hemoglobin below 90 g/L and 20 patients with a ASA grade of 3 (p < 0.05). 78.5% patients with A2 fracture and 75% of A3 fractures needed blood transfusion (p > 0.05). Length of hospital stay in non-transfusion group was 13 days and in transfusion group was 19 days (p < 0.05). 55.1% operated within 36 h and 47.6% operated after 36 h of admission needed transfusion (p > 0.05). Thirty-day mortality in patients needing blood transfusion was 5% and in non-transfusion group was 3.7% (p > 0.05). Patient age, ASA grade, preoperative haemoglobin and length of nail are reliable predictors for perioperative blood transfusion in extra capsular hip fractures in elderly patients treated with cephalo-medullary nailing and reinforce a selective transfusion policy. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  12. Paediatric tibial shaft fractures treated by open reduction and stabilization with monolateral external fixation

    PubMed Central

    Simon, A.-L.; Apostolou, N.; Vidal, C.; Ferrero, E.; Mazda, K.; Ilharreborde, B.

    2018-01-01

    Abstract Purpose Elastic stable intramedullary nailing is increasingly used for surgical treatment of tibial shaft fractures, but frequently requires immobilization and delayed full weight-bearing. Therefore, external fixation remains interesting. The aim was to report clinico-radiological outcomes of monolateral external fixation for displaced and unstable tibial shaft fractures in children. Methods All tibial fractures consecutively treated by monolateral external fixation between 2008 and 2013 were followed. Inclusion criteria included skeletal immaturity and closed and open Gustilo I fractures caused by a direct impact. Patients were seen until two years postoperatively. Demographics, mechanism of injury, surgical data and complications were recorded. Anteroposterior and lateral side radiographs were performed at each visit. Full-limb 3D reconstructions using biplanar stereroradiography was performed for final limb length and alignment measures. Results A total of 45 patients (mean age 9.7 years ± 0.5) were included. In all, 17 were Gustilo I fractures, with no difference between open and closed fractures for any data. Mean time to full weight bearing was 18.2 days ± 0.7. After 15 days, 39 patients returned to school. Hardware removal (mean time to union 15.6 weeks ± 0.8) was performed during consultation under analgesic gas. There were no cases of nonunion. No fracture healed with > 10° of angulation (mean 5.1° ± 0.4°). Leg-length discrepancy > 10 mm was found for six patients. Conclusions This procedure can be a safe and simple surgical treatment for children with tibial shaft fractures. Few complications and early return to school were reported, with the limitations of non-comparative study. Level of Evidence IV PMID:29456750

  13. Can the displacement of a conservatively treated distal radius fracture be predicted at the beginning of treatment?

    PubMed Central

    Einsiedel, T.; Freund, W.; Sander, S.; Trnavac, S.; Gebhard, F.

    2008-01-01

    The aim of this study was to investigate whether the final displacement of conservatively treated distal radius fractures can be predicted after primary reduction. We analysed the radiographic documents of 311 patients with a conservatively treated distal radius fracture at the time of injury, after reduction and after bony consolidation. We measured the dorsal angulation (DA), the radial angle (RA) and the radial shortening (RS) at each time point. The parameters were analysed separately for metaphyseally “stable” (A2, C1) and “unstable” (A3, C2, C3) fractures, according to the AO classification system. Spearman’s rank correlations and regression functions were determined for the analysis. The highest correlations were found for the DA between the time points ‘reduction’ and ‘complete healing’ (r = 0.75) and for the RA between the time points ‘reduction’ and ‘complete healing’ (r = 0.80). The DA and the RA after complete healing can be predicted from the regression functions. PMID:18504577

  14. Validation of a 3D CT method for measurement of linear wear of acetabular cups

    PubMed Central

    2011-01-01

    Background We evaluated the accuracy and repeatability of a 3D method for polyethylene acetabular cup wear measurements using computed tomography (CT). We propose that the method be used for clinical in vivo assessment of wear in acetabular cups. Material and methods Ultra-high molecular weight polyethylene cups with a titanium mesh molded on the outside were subjected to wear using a hip simulator. Before and after wear, they were (1) imaged with a CT scanner using a phantom model device, (2) measured using a coordinate measurement machine (CMM), and (3) weighed. CMM was used as the reference method for measurement of femoral head penetration into the cup and for comparison with CT, and gravimetric measurements were used as a reference for both CT and CMM. Femoral head penetration and wear vector angle were studied. The head diameters were also measured with both CMM and CT. The repeatability of the method proposed was evaluated with two repeated measurements using different positions of the phantom in the CT scanner. Results The accuracy of the 3D CT method for evaluation of linear wear was 0.51 mm and the repeatability was 0.39 mm. Repeatability for wear vector angle was 17°. Interpretation This study of metal-meshed hip-simulated acetabular cups shows that CT has the capacity for reliable measurement of linear wear of acetabular cups at a clinically relevant level of accuracy. PMID:21281259

  15. External fixation of tibial pilon fractures and fracture healing.

    PubMed

    Ristiniemi, Jukka

    2007-06-01

    Distal tibial fractures are rare and difficult to treat because the bones are subcutaneous. External fixation is commonly used, but the method often results in delayed union. The aim of the present study was to find out the factors that affect fracture union in tibial pilon fractures. For this purpose, prospective data collection of tibial pilon fractures was carried out in 1998-2004, resulting in 159 fractures, of which 83 were treated with external fixation. Additionally, 23 open tibial fractures with significant > 3 cm bone defect that were treated with a staged method in 2000-2004 were retrospectively evaluated. The specific questions to be answered were: What are the risk factors for delayed union associated with two-ring hybrid external fixation? Does human recombinant BMP-7 accelerate healing? What is the role of temporary ankle-spanning external fixation? What is the healing potential of distal tibial bone loss treated with a staged method using antibiotic beads and subsequent autogenous cancellous grafting compared to other locations of the tibia? The following risk factors for delayed healing after external fixation were identified: post-reduction fracture gap of >3 mm and fixation of the associated fibula fracture. Fracture displacement could be better controlled with initial temporary external fixation than with early definitive fixation, but it had no significant effect on healing time, functional outcome or complication rate. Osteoinduction with rhBMP-7 was found to accelerate fracture healing and to shorten the sick leave. A staged method using antibiotic beads and subsequent autogenous cancellous grafting proved to be effective in the treatment of tibial bone loss. Healing potential of the bone loss in distal tibia was at least equally good as in other locations of the tibia.

  16. The outcome of surgically treated traumatic unstable pelvic fractures by open reduction and internal fixation.

    PubMed

    Mardanpour, Keykhosro; Rahbar, Mahtab

    2013-07-01

    This study was performed to evaluate functional and radiological results of pelvic ring fractures treatment by open reduction and internal fixation. Thirty eight patients with unstable pelvic fractures, treated from 2002 to 2008 were retrospectively reviewed. The mean patients' age was 37 years (range 20 to 67). Twenty six patients were men (4 patients with type B and 22 patients with type C fracture) and 12 women (7 patients with type B and 5 patients with type C fracture). The commonest cause was a road traffic accident (N=37, about 97%). Internal fixation was done by plaque with ilioinguinal and Kocher-Langenbeek approaches for anterior, posterior pelvic wall and acetabulum fracture respectively. Quality of reduction was graded according to Majeed score system. There were 11 type-C and 27 type-B pelvic fractures according to Tile's classification. Thirty six patients sustained additional injuries. The commonest additional injury was lower extremity fracture. The mean follow-up was 45.6 months (range 16 to 84 months).The functional outcome was excellent in 66%, good in 15%, fair in 11% and poor in 7% of the patients with type B pelvic fractures and functional outcome was excellent in 46%, good in 27%, fair in 27% and poor in 0% of the patients with type C pelvic fractures. There were four postoperative infections. No sexual functional problem was reported. Neurologic problem like Lateral cutaneous nerve of thigh injury recovered completely in 2 patients and partially in 2 patients. There was no significant relation between functional outcome and the site of fracture (P greater than 0.005). Unstable pelvic ring fracture injuries should be managed surgically by rigid stabilization. It must be carried out as soon as the general condition of the patient permits, and even up to two weeks.

  17. Characteristics of foot fractures in HIV-infected patients previously treated with tenofovir versus non-tenofovir-containing highly active antiretroviral therapy.

    PubMed

    Horizon, Arash A; Joseph, Robert J; Liao, Qiming; Ross, Steven T; Pakes, Gary E

    2011-01-01

    In a retrospective case series study, medical records were evaluated for all male patients infected with human immunodeficiency virus (HIV) diagnosed over a one-year period with foot fractures (n = 30) confirmed by magnetic resonance imaging at a Los Angeles outpatient private practice rheumatology clinic. Proportionally more patients had received tenofovir prefracture (17 [57%]) than those who had not (13 [43%]). At fracture diagnosis, these two groups were similar in median age (49 versus 48 years), HIV-1 RNA (both 1.7 log(10) copies/mL), CD4 count (300 versus 364/mm(3)), time between HIV diagnosis and foot fracture (both 17 years), family history of degenerative bone disease (24% versus 23%), prevalence of malabsorption syndrome, renal failure, calcium deficiency, or vitamin D deficiency, and concurrent use of bisphosphonates, calcitonin, and diuretics. However, more tenofovir-treated patients had osteoporosis (35% versus 8%), stress-type fractures (53% versus 31%), concurrent fractures (12% versus 0%), wasting syndrome (29% versus 15%), truncal obesity (18% versus 8%), smoked cigarettes (more than one pack/day for more than one year; 35% versus 8%), dual energy X-ray absorptiometry (DEXA) T scores < -2.4 (denoting osteoporosis) at the femur (24% versus 9%) and spine (47% versus 36%), and had received protease inhibitors (71% versus 46%), non-nucleoside reverse transcriptase inhibitors (24% versus 0%), prednisone (24% versus 0%), testosterone (47% versus 23%), and teriparatide (29% versus 8%). Median time from tenofovir initiation until fracture was 2.57 (range 1.17-5.69) years. In conclusion, more foot fractures were observed in tenofovir-treated patients than in non-tenofovir-treated patients with HIV infection. Comorbidities and/or coadministered drugs may have been contributory.

  18. Long-term outcome of pronation-external rotation ankle fractures treated with syndesmotic screws only.

    PubMed

    Lambers, Kaj T A; van den Bekerom, Michel P J; Doornberg, Job N; Stufkens, Sjoerd A S; van Dijk, C Niek; Kloen, Peter

    2013-09-04

    There is sparse information in the literature on the outcome of Maisonneuve-type pronation-external rotation ankle fractures treated with syndesmotic screws. The primary aim of this study was to determine the long-term results of such treatment of these fractures as indicated by standardized patient-based and physician-based outcome measures. The secondary aim was to identify predictors of the outcome with use of bivariate and multivariate statistical analysis. Fifty patients with pronation-external rotation (predominantly Maisonneuve) fractures were treated with open reduction and internal fixation of the syndesmosis utilizing only one or two screws. The results were evaluated at a mean of twenty-one years after the fracture utilizing three standardized outcomes instruments: (1) the Foot and Ankle Ability Measure (FAAM), (2) the American Orthopaedic Foot & Ankle Society (AOFAS) ankle-hindfoot scale, and (3) the Center for Epidemiologic Studies-Depression (CES-D) Scale. Osteoarthritis was graded according to the van Dijk and revised Takakura radiographic scoring systems. Bivariate and multivariate analyses were performed to identify predictors of long-term outcome. Forty-four (92%) of forty-eighty patients had good or excellent AOFAS scores, and forty-four (90%) of forty-nine had good or excellent FAAM scores. Arthrodesis for severe osteoarthritis was performed in two patients. Radiographic evidence of osteoarthritis was observed in twenty-four (49%) of forty-nine patients. Multivariate analysis identified pain as the most important independent predictor of long-term ankle function as indicated by the AOFAS and FAAM scores, explaining 91% and 53% of the variation in scores, respectively. Analysis of pain as the dependent variable in bivariate analyses revealed that depression, ankle range of motion, and a subsequent surgery were significantly correlated with higher pain scores. No firm conclusions could be drawn after multivariate analysis of predictors of pain

  19. The incidence of pelvic fractures with traumatic lower limb amputation in modern warfare due to improvised explosive devices.

    PubMed

    Cross, A M; Davis, C; Penn-Barwell, J; Taylor, D M; De Mello, W F; Matthews, J J

    2014-01-01

    A frequently-seen injury pattern in current military experience is traumatic lower limb amputation as a result of improvised explosive devices (IEDs). This injury can coexist with fractures involving the pelvic ring. This study aims to assess the frequency of concomitant pelvic fracture in IED-related lower limb amputation. A retrospective analysis of the trauma charts, medical notes, and digital imaging was undertaken for all patients arriving at the Emergency Department at the UK military field hospital in Camp Bastion, Afghanistan, with a traumatic lower limb amputation in the six months between September 2009 and April 2010, in order to determine the incidence of associated pelvic ring fractures. Of 77 consecutive patients with traumatic lower limb amputations, 17 (22%) had an associated pelvic fracture (eleven with displaced pelvic ring fractures, five undisplaced fractures and one acetabular fracture). Unilateral amputees (n = 31) had a 10% incidence of associated pelvic fracture, whilst 30 % of bilateral amputees (n = 46) had a concurrent pelvic fracture. However, in bilateral, trans-femoral amputations (n = 28) the incidence of pelvic fracture was 39%. The study demonstrates a high incidence of pelvic fractures in patients with traumatic lower limb amputations, supporting the routine pre-hospital application of pelvic binders in this patient group.

  20. [Early results of proximal femoral fractures treated with FENIX modular hemiarthroplasty].

    PubMed

    Görski, Radosław; Górecki, Andrzej; Olszewski, Paweł; Biedrzycki, Jerzy; Skowronek, Paweł

    2010-01-01

    The article discusses preliminary clinical results in patients with proximal femoral fractures treated with hemiarthroplasty using a FENIX implant. The study group comprised 41 subjects aged 69 to 97 (median age 82.3 year). The follow-up study provided data on 26 subjects (63.4%), among which 15 attended the check-up, 5 subjects refused to visit at the Department and 6 subjects were reported as deceased. Median follow-up period amounted to 6.8 month (1 to 22 months). General hospitalization-related complications occurred in 8 patients (19.5%). During hospitalization no deaths occurred, in the deceased group 3 patients died within 12 months after surgery, while another 3 died after the twelve-month postoperative period (median of 13.3%). According to Merle d'Aubigne-Postel score favorable long-term results were observed in 9 patients (59.9%), 13 patients regained the level of motor function similar to the functional ability prior to fracture. The need to postpone the surgery due to general health status and impaired pre-operative motor function are significant negative prognostic factors. The results obtained were compared with previous efficacy studies on femoral fracture treatment using an Austin-Moore implant. Functional ability and self-reliance was higher in the FENIX group. FENIX arthroplasty effectively helps patients regain self-reliance and motor function thanks to its modular characteristics and anatmoical construction.

  1. Treating Eyres type IV and V coracoid fracture using the acromion osteotomy approach.

    PubMed

    Wu, Jin; Fu, Xi-jin; Sha, Mo; Liu, Hui; Chen, Zhi-da; Kang, Liang-qi

    2016-02-01

    To introduce a surgical method of treating Eyres type IV and V coracoid fracture using the acromion osteotomy approach and to further analyse the clinical effectiveness of this surgical procedure. Nine patients were included in this study with a mean follow-up time of 23.3 months (range, 14.0-34.0 months). Patients were evaluated with use of the Constant score, the Simple Shoulder Test (SST) score and a visual analogue scale (VAS) pain score. Moreover, the shoulder range of motion was also observed. The mean operation time was 91.6 min with a blood loss volume ranging from 310 to 530 ml. The fractures of eight patients had recovered between 10 and 12 weeks post operation with no signs of infection, screw loosening, plate breaking or other internal fixation failures, while one case had non-union at 34 months' follow-up. The mean Constant score increased from 75.6 points preoperatively to 91.0 points at follow-up. The mean VAS score decreased from 5.3 preoperatively to 1.0 at follow-up, while the average SST score increased from 7.1 points preoperatively to 10.0 points at follow-up. The mean abduction, forward flexion, external rotation, internal rotation and backward extension angles were 162°, 159° 50°, 55° and 47°. Five cases were classified as excellent, three cases were marked as good and one case was classified as fair. Treating coracoid fracture through the approach of acromion osteotomy could be an effective treatment option with minimise damages.

  2. Surgical interventions for treating acute fractures or non-union of the middle third of the clavicle.

    PubMed

    Lenza, Mário; Faloppa, Flávio

    2015-05-07

    This review covers two conditions: acute clavicle fractures and non-union resulting from failed fracture healing. Clavicle (collarbone) fractures account for around 4% of all fractures. While treatment for these fractures is usually non-surgical, some types of clavicular fractures, as well as non-union of the middle third of the clavicle, are often treated surgically. This is an update of a Cochrane review first published in 2009. To evaluate the effects (benefits and harms) of different methods of surgical treatment for acute fracture or non-union of the middle third of the clavicle. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register (27 June 2014), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2014, Issue 5), MEDLINE (1966 to June week 3 2014), EMBASE (1988 to 2014 week 25), LILACS (1982 to 27 June 2014), trial registries and reference lists of articles. We applied no language or publication restrictions. We considered randomised and quasi-randomised controlled trials evaluating any surgical intervention for treating people with fractures or non-union of the middle third of the clavicle. The primary outcomes were shoulder function or disability, pain and treatment failure (measured by the number of participants who had undergone or were being considered for a non-routine secondary surgical intervention for symptomatic non-union, malunion or other complications). Two review authors selected eligible trials, independently assessed risk of bias and cross-checked data. Where appropriate, we pooled results of comparable trials. We included seven trials in this review with 398 participants. Four trials were new in this update.The four new trials (160 participants) compared intramedullary fixation with open reduction and internal fixation with plate for treating acute middle third clavicle fractures in adults. Low quality evidence from the four trials indicated that intramedullary fixation did not

  3. A cemented cup with acetabular impaction bone grafting is more cost-effective than an uncemented cup in patients under 50 years.

    PubMed

    Busch, Vincent J J F; Verschueren, Joost; Adang, Eddy M; Lie, Stein A; Havelin, Leif I; Schreurs, Berend W

    2016-01-01

    Acetabular deficiencies in young patients can be restored in several ways during total hip arthroplasty. Currently, cementless cups are most frequently used. Impaction bone grafting of acetabular defects is a more biological approach, but is it cost-effective in young patients on the long term? We designed a decision model for a cost-utility analysis of a cemented cup with acetabular impaction bone grafting versus an uncemented cup, in terms of cost per quality-adjusted life year (QALY) for the young adult with acetabular bone deficiency, in need for a primary total hip arthroplasty. Outcome probabilities and effectiveness were derived from the Radboud University Nijmegen Medical Centre and the Norwegian Hip Register. Multiple sensitivity analyses were used to assess the contribution of the included variables in the model's outcome. Cemented cups with impaction bone grafting were more cost-effective compared to the uncemented option in terms of costs per QALY. A scenario suggesting equal primary survival rates of both cemented and uncemented cups still showed an effect gain of the cemented cup with impaction bone grafting, but at higher costs. Based on this model, the first choice of treatment of the acetabular bone deficient osteoarthritic hip in a young patient is reconstruction with impaction bone grafting and a cemented cup.

  4. Examination of acetabular labral tear: a continued diagnostic challenge.

    PubMed

    Reiman, Michael P; Mather, Richard C; Hash, Thomas W; Cook, Chad E

    2014-02-01

    Acetabular labrum tears (ALT) are present in 22-55% of individuals with hip or groin pain. Tears can occur as a result of trauma or degeneration and are markedly associated with femoral acetabular morphological variations. An ALT can lead to biomechanical deficiencies and a loss of stability to the coxafemoral joint due to the labrum serving as a stabilising structure of this joint. The diagnosis of ALT is complex and multidimensional. Although tremendous improvements in diagnostic utility for ALT have occurred in the past 25 years, there are few patient history, clinical examination and special test findings that are unique to the condition. Imaging methods such as MRI, CT and ultrasonography have demonstrated reasonable accuracy, but not at a level that allows use as a stand-alone measure. Outcomes measures that focus on functional limitation or that are used to measure recovery should envelop the complexities of the condition and be captured using both self-report and physical performance measures. Only when patient history, objective testing, clinical examination special testing and imaging are combined can a clinician fully elucidate the multidimensional diagnosis of ALT.

  5. Low Frequency of Early Complications With Dual-mobility Acetabular Cups in Cementless Primary THA.

    PubMed

    Chughtai, Morad; Mistry, Jaydev B; Diedrich, Aloise M; Jauregui, Julio J; Elmallah, Randa K; Bonutti, Peter M; Harwin, Steven F; Malkani, Arthur L; Kolisek, Frank R; Mont, Michael A

    2016-10-01

    Dislocation complicates 1% to 5% of primary total hip arthroplasties (THAs). As a result, some surgeons consider dual-mobility articulations, which are usually used in the revision setting to decrease the likelihood of dislocation, as an option for primary THA. However, few studies have evaluated their use in this setting. (1) What is the cup survivorship when the dual-mobility articulation is used in the setting of primary THA? (2) What are the clinical outcomes with this approach? (3) What are the radiographic outcomes? (4) What are the complications of dual-mobility articulations in primary THA? Between 2011 and 2013, the five participating surgeons performed 495 cementless primary THAs. During that time, one of the five surgeons used dual-mobility articulations for all THAs, and the other four used it whenever the acetabular cup size was 52 mm or greater to enable a 28-mm head. Of the 495 patients, 453 (92%) were performed using this device. Smaller patients were treated with a standard THA. Of the 453 patients, a total of 43 patients (10%) were lost to followup before the 2-year minimum. The resulting 410 patients who were included in the analysis (164 men, 246 women) had a mean age of 64 years (SD, 12 years). The mean followup was 3 years (SD, 0.7 years). We performed Kaplan-Meier analyses to assess survivorship to aseptic failure and all-cause acetabular component survivorship. Clinical outcomes were evaluated using the Harris hip score (HHS); radiographs were assessed for cup migration, progressive radiolucencies, and positional changes of the components; and any surgery-related complications were recorded. The survivorship to aseptic failure and all-cause acetabular component survivorship was 99.8% (failures, n = 1) (95% confidence interval [CI], 4.517-4.547) and 99.3% (failures, aseptic, n = 1; septic, n = 2) (95% CI, 4.494-4.543); one hip had trunnion notching caused by impingement of a malpositioned cup, which was treated with revision of the cup and

  6. The Bimetric cementless total hip replacement: 7–18 year follow-up assessing the influence of acetabular design on survivorship

    PubMed Central

    Ghassemi, A.; Dorrell, J. H.; Powles, D. P.

    2008-01-01

    The purpose of this study was to evaluate the mid- to long-term survivorship of Bimetric cementless total hip replacement and assess how it is affected by the acetabular design. This was a retrospective analysis of 127 Bimetric cementless total hip replacements in 110 patients with a follow-up of 7–18 years. A single design stem and three different cementless metal-backed acetabular designs were used. Patients were assessed clinically using the Harris hip score and radiologically by independent review of current hip radiographs. There was only one case of aseptic loosening of the femoral stem. The earliest acetabular design showed a high failure rate whilst the latter two designs showed a 96% survivorship at a mean of 9.5 years. We conclude that a combination of the bimetric stem with either of the latter acetabular cup designs has a good mid- to long-term performance. PMID:18551293

  7. [Hip Fracture--Epidemiology, Management and Liaison Service. What do we need to close care gaps in treating hip fracture?--How to include the UK experience into the care in Japan].

    PubMed

    Takahashi, Hideaki E

    2015-04-01

    Various care gaps are noted in and between acute and rehabilitation hospitals, and after discharge from hospitals in Japan. In the most of acute care hospitals physicians take care of elderly fractured patients only by a request of orthopaedic team. This made a mean time until surgery was 4.5 days (2011). A critical pathway in treating hip fracture has certainly shortened days in the acute hospitals, care gaps may exist between hospitals. Although osteoporosis medication has started on discharge, it may be discontinued at home, in health or social care facilities under the care of primary care physicians. Even though it was estimated approximately 160,000 hip fractures per year in Japan, management of patients' address is not well established after discharge. In order to include the UK experience in Japan, two proposals were made for hospitals in treating hip fracture as follows. 1. Clinical auditing may be added to improve quality of care. An audit protocol is to be developed multidisciplinarily by orthopaedic surgeons and geriatricians, with interprofessional collaboration. 2. A fracture liaison service is to be established to make interprofessional care-mix possible, such as an increase of adherence of osteoporosis drugs and prevention of falls after discharge. A fracture liaison coordinator is to be assigned to the service in making a team approach possible to a patient and his/her family.

  8. The clinical application of absorbable intramedullary nail and claw plate on treating multiple rib fractures.

    PubMed

    Chai, X; Lin, Q; Ruan, Z; Zheng, J; Zhou, J; Zhang, J

    2013-08-01

    The absorption intramedullary nail and claw plate indications and efficacy were investigated in the treatment of a life-threatening multiple rib fractures. A retrospective analysis of 248 surgically treated rib fracture patients was performed who admitted to our hospital from March 2007 to December 2012. Intramedullary nailing was performed in 28 cases, a claw-type bone plate was fixed in 141 cases, and a combination of both was fixed in 79 cases. All internal fixation patients were clinically cured except 1 patient died 14 days after a massive pulmonary embolism. The patients with flail chest and floating chest wall causing respiratory and circulatory disorders were promptly corrected. Routine follow-up was from 1 to 2 years, displaced fractures were in 2 cases, and there were 11 cases of internal fixation and extraction. Internal fixation is a simple and reliable method for the treatment of multiple rib fractures. Both internal fixation materials have their pros and cons but the claw bone plate is more robust. The actual selection of appropriate treatment options helps to improve the treatment efficacy.

  9. Malleolar fractures and their ligamentous injury equivalents have similar outcomes in supination-external rotation type IV fractures of the ankle treated by anatomical internal fixation.

    PubMed

    Berkes, M B; Little, M T M; Lazaro, L E; Sculco, P K; Cymerman, R M; Daigl, M; Helfet, D L; Lorich, D G

    2012-11-01

    It has previously been suggested that among unstable ankle fractures, the presence of a malleolar fracture is associated with a worse outcome than a corresponding ligamentous injury. However, previous studies have included heterogeneous groups of injury. The purpose of this study was to determine whether any specific pattern of bony and/or ligamentous injury among a series of supination-external rotation type IV (SER IV) ankle fractures treated with anatomical fixation was associated with a worse outcome. We analysed a prospective cohort of 108 SER IV ankle fractures with a follow-up of one year. Pre-operative radiographs and MRIs were undertaken to characterise precisely the pattern of injury. Operative treatment included fixation of all malleolar fractures. Post-operative CT was used to assess reduction. The primary and secondary outcome measures were the Foot and Ankle Outcome Score (FAOS) and the range of movement of the ankle. There were no clinically relevant differences between the four possible SER IV fracture pattern groups with regard to the FAOS or range of movement. In this population of strictly defined SER IV ankle injuries, the presence of a malleolar fracture was not associated with a significantly worse clinical outcome than its ligamentous injury counterpart. Other factors inherent to the injury and treatment may play a more important role in predicting outcome.

  10. Complex proximal humeral fractures: a prospective study of 22 cases treated using the "Bilboquet" device.

    PubMed

    Doursounian, L; Kilinc, A; Cherrier, B; Nourissat, G

    2011-02-01

    Despite recent improvements in surgical devices, complex proximal humerus fractures internal fixation still encounters frequent mechanical failures. The aim of this study was to confirm that the Bilboquet device (a design mimicking the cup-and-ball game) helps solving mechanical difficulties associated with these fractures internal fixation and to present a simplified version of the original surgical procedure. This non-randomised prospective study included 22 fractures in 22 patients, mean age: 70 years. According to the Neer classification there were three-part fractures in seven cases and four-part fractures in 15 cases. Fractures were all reduced and treated by internal fixation in a simplified surgical procedure using the Bilboquet device. Mean postoperative follow-up was 34 months. The mean Constant score was 66 and the weighted Constant score was 86. Mean active forward elevation was 108° and mean active external rotation was 28°. No per- or postoperative complications occurred. Initial reduction of the tuberosity was incomplete in four cases. Union was obtained in all fractures. There was no secondary tilting of the head, and no migration or pseudarthrosis of the tuberosities. Five patients developed postoperative avascular necrosis of the humeral head. The Bilboquet staple component provides a supporting platform for the entire humeral head area. This peripheral stabilization associated with tension band wiring explains the lack of secondary displacement in these cases. Although the Bilboquet device provides a solution to the mechanical problems of complex fractures of the proximal humerus, it does not solve the problem of secondary avascular necrosis of the humeral head, which occurred in 23% of the patients in this series and in 33% of patients in the four-part fractures subgroup. IV (non-randomised prospective study). Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  11. Surgery for scapula process fractures

    PubMed Central

    Anavian, Jack; Wijdicks, Coen A; Schroder, Lisa K; Vang, Sandy

    2009-01-01

    Background Generally, scapula process fractures (coracoid and acromion) have been treated nonoperatively with favorable outcome, with the exception of widely displaced fractures. Very little has been published, however, regarding the operative management of such fractures and the literature that is available involves very few patients. Our hypothesis was that operative treatment of displaced acromion and coracoid fractures is a safe and effective treatment that yields favorable surgical results. Methods We reviewed 26 consecutive patients (27 fractures) treated between 1998 and 2007. Operative indications for these process fractures included either a painful nonunion, a concomitant ipsilateral operative scapula fracture, ≥ 1 cm of displacement on X-ray, or a multiple disruption of the superior shoulder suspensory complex. All patients were followed until they were asymptomatic, displayed radiographic fracture union, and had recovered full motion with no pain. Patients and results 21 males and 5 females, mean age 36 (18–67) years, were included in the study. 18 patients had more than one indication for surgery. Of the 27 fractures, there were 13 acromion fractures and 14 coracoid fractures. 1 patient was treated for both a coracoid and an acromion fracture. Fracture patterns for the acromion included 6 acromion base fractures and 7 fractures distal to the base. Coracoid fracture patterns included 11 coracoid base fractures and 3 fractures distal to the base. Mean follow-up was 11 (2–42) months. All fractures united and all patients had recovered full motion with no pain at the time of final follow-up. 3 patients underwent removal of hardware due to irritation from hardware components that were too prominent. There were no other complications. Interpretation While most acromion and coracoid fractures can be treated nonoperatively with satisfactory results, operative management may be indicated for displaced fractures and double lesions of the superior shoulder

  12. [Total hip arthroplasty in post-dysplastic hip arthritis. Can type and position of the acetabular component influence longevity of the prosthesis?].

    PubMed

    Fousek, J; Indráková, P

    2007-02-01

    The aim of the study was a retrospective evaluation of our patients with post-dysplastic hips treated by cemented or non-cemented total hip arthroplasty (THA) in order to ascertain which type and position of the acetabular component was most effective. In the years 1999-2002, 111 THA procedures were performed in 93 patients, 76 women and 17 men, with post-dysplastic hip arthritis. The average age of the patients at the time of implantation was 52.6 years. On the basis of pre-operative radiographic findings, the patients' conditions were evaluated using the Hartofilakidis classification into three disease categories: dysplasia, low dislocation and high dislocation, and the patients were placed in two groups. Group 1 included 78 patients, and group 2 comprised 26 patients. None of our patients was classified as having high dislocation. Thirty-nine of these patients had previously undergone surgery for dysplastic hips. A total of 104 THAs were evaluated, because radiographic data was incomplete in seven cases. In addition to X-ray findings, the prosthesis type (cemented, hybrid, non-cemented), post-operative complications and signs of loosening were included in the evaluation. Clinical outcomes were assessed by the Harris score. The follow-up terminating on 31st December 2005 was 67 months on the average. In group 1 patients, the average Harris score increased from 38.6 to 80.3 points and in group 2 patients from 35.5 to 84.9 points, mostly with excellent and good results. In 72.1 % of the hips, a press-fit acetabular component was implanted. In 55.8 % of the cases, the acetabular component was implanted off the anatomical center of rotation, into the high hip center, with the range from 9 to 20 mm and an average of 15 mm. The average limb lengthening was 2.5 cm, ranging from 1.0 to 3.5 cm. Our results show that it is more effective to use non-cemented THA for post-dysplastic hips. The implantation of a noncemented acetabular component into the high center provides

  13. Effect of Retained Austenite on the Fracture Toughness of Quenching and Partitioning (Q&P)-Treated Sheet Steels

    NASA Astrophysics Data System (ADS)

    Wu, Riming; Li, Wei; Zhou, Shu; Zhong, Yong; Wang, Li; Jin, Xuejun

    2014-04-01

    Fracture toughness K IC was measured by double edge-notched tension (DENT) specimens with fatigue precracks on quenching and partitioning (Q&P)-treated high-strength (ultimate tensile strength [UTS] superior to 1200 MPa) sheet steels consisting of 4 to 10 vol pct of retained austenite. Crack extension force, G IC, evaluated from the measured K IC, is used to analyze the role of retained austenite in different fracture behavior. Meanwhile, G IC is deduced by a constructed model based on energy absorption by martensite transformation (MT) behavior of retained austenite in Q&P-treated steels. The tendency of the change of two results is in good agreement. The Q&P-treated steel, quenched at 573 K (300 °C), then partitioned at 573 K (300 °C), holding for 60 seconds, has a fracture toughness of 74.1 MPa·m1/2, which is 32 pct higher than quenching and tempering steel (55.9 MPa·m1/2), and 16 pct higher than quenching and austempering (QAT) steel (63.8 MPa·m1/2). MT is found to occur preferentially at the tips of extension cracks on less stable retained austenite, which further improves the toughness of Q&P steels; on the contrary, the MT that occurs at more stable retained austenite has a detrimental effect on toughness.

  14. The use of an Ossis custom 3D-printed tri-flanged acetabular implant for major bone loss: minimum 2-year follow-up: Short title: Ossis custom 3D-Printed tri-flanged acetabular implant.

    PubMed

    Kieser, David C; Ailabouni, Ramez; Kieser, Sandra C J; Wyatt, Michael C; Armour, Paul C; Coates, Mark H; Hooper, Gary J

    2018-05-01

    Custom 3D-printed acetabular implants are a new technology used in hip surgery with ever-increasing frequency. They offer patient-specific implants to optimise filling of bone defects and implant-bone contact, without the need for excessive bone resection. This is a retrospective cohort study of 46 consecutive patients who underwent an Ossis unilateral custom 3D-printed acetabular implant. Clinical (Oxford Hip Score OHS-60), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS) and radiological (restoration of biomechanical hip centre, osteointegration, wear, heterotrophic ossification) results were assessed. Patient mean age was 68 years and follow-up was 38 months (minimum 24 months). 10 patients were excluded from the outcome analysis; 2 patients died, 1 required revision for deep infection and 7 were lost to follow-up. Of the 36 patients included, 21 had severe osteolysis. 7 were revised for infection, 3 for tumoural defects, 3 for metallosis, 1 for dysplasia and 1 for trauma (Paprosky 2a [n=6], 2b [n=2], 2c [n=5], 3a [n=6], 3b [n=11], pelvic dissociation [n=6]). OHS significantly improved postoperatively (16-8-48.4 p=0.027). Postoperative functional scores were good (WOMAC 98; HHS 79). The biomechanical hip centre was restored in all patients. 1 patient had early implant migration with subsequent stabilisation. 2 patients had radiographs concerning for failure of osteointegration. 1 patient had recurrent dislocations. The mid-term results of the Ossis custom 3D-printed tri-flanged acetabular implant for the management of severe acetabular defects are encouraging. The improvement in functional scores and radiographic outcomes are comparable to similar designs. In addition, no cases have required revision for aseptic loosening.

  15. Early Weightbearing After Operatively Treated Ankle Fractures: A Biomechanical Analysis.

    PubMed

    Tan, Eric W; Sirisreetreerux, Norachart; Paez, Adrian G; Parks, Brent G; Schon, Lew C; Hasenboehler, Erik A

    2016-06-01

    No consensus exists regarding the timing of weightbearing after surgical fixation of unstable traumatic ankle fractures. We evaluated fracture displacement and timing of displacement with simulated early weightbearing in a cadaveric model. Twenty-four fresh-frozen lower extremities were assigned to Group 1, bimalleolar ankle fracture (n=6); Group 2, trimalleolar ankle fracture with unfixed small posterior malleolar fracture (n=9); or Group 3, trimalleolar ankle fracture with fixed large posterior malleolar fracture (n=9) and tested with axial compressive load at 3 Hz from 0 to 1000 N for 250 000 cycles to simulate 5 weeks of full weightbearing. Displacement was measured by differential variable reluctance transducer. The average motion at all fracture sites in all groups was significantly less than 1 mm (P < .05). Group 1 displacement of the lateral and medial malleolus fracture was 0.1±0.1 mm and 0.4±0.4 mm, respectively. Group 2 displacement of the lateral, medial, and posterior malleolar fracture was 0.6±0.4 mm, 0.5±0.4 mm, and 0.5±0.6 mm, respectively. Group 3 displacement of the lateral, medial, and posterior malleolar fracture was 0.1±0.1 mm, 0.5±0.7 mm, and 0.5±0.4 mm, respectively. The majority of displacement (64.0% to 92.3%) occurred in the first 50 000 cycles. There was no correlation between fracture displacement and bone mineral density. No significant fracture displacement, no hardware failure, and no new fractures occurred in a cadaveric model of early weightbearing in unstable ankle fracture after open reduction and internal fixation. This study supports further investigation of early weightbearing postoperative protocols after fixation of unstable ankle fractures. © The Author(s) 2016.

  16. Preservation of the Acetabular Cup During Revision Total Hip Arthroplasty Using a Novel Mini-navigation Tool: A Case Report.

    PubMed

    Vincent, John; Alshaygy, Ibrahim; Muir, Jeffrey M; Kuzyk, Paul

    2018-01-01

    While intraoperative navigation systems have been shown to improve outcomes in primary total hip arthroplasty (THA), their use in the context of revision has been largely overlooked. This case report presents the first documented use of an imageless navigation tool in the context of revision THA, and an unexpected benefit to the surgical procedure as a result. An 84-year-old female patient presented following five episodes of dislocation of the left hip and with pain in the left buttock, groin, and posterior aspect of her hip. Relevant surgical history included primary hip arthroplasty in 1999 and the first revision in 2014. Preoperative analysis revealed a constrained liner that had become disengaged and migrated inferiorly, lodging at the distal aspect of the femoral neck. Acetabular protrusion was also noted. The pre-operative plan included the replacement of the fragmented liner and likely of the acetabular cup due to hardware failure. Intraoperative assessment, however, revealed that the cup was in good condition and would be difficult to remove due to substantial bony ingrowth. With the assistance of imageless navigation, the orientation of the acetabular cup was determined and a new constrained liner was cemented into the preexisting acetabular component at an altered orientation, correcting anteversion by 7°. In revision hip arthroplasty cases, image-based navigation is limited by the presence of existing implants and corresponding metal artefact. This case demonstrates the successful use of an imageless navigation tool for revision surgery. Use of navigation led to the unexpected intraoperative discovery that the acetabular cup was in an acceptable state, and allowed the surgical team to correct the position of the cup using a constrained liner, thus preserving the cup. This significantly benefitted patient outcome, due to the risks associated with the removal of a firmly fixated acetabular cup. While more extensive research is required, this case

  17. Press-fit acetabular cup fixation: principles and testing.

    PubMed

    Macdonald, W; Carlsson, L V; Charnley, G J; Jacobsson, C M

    1999-01-01

    Pre-clinical testing of the fixation of press-fit acetabular components of total hip prostheses relies on cadaver or synthetic bone, but the properties and geometry of bone models differ from those of physiological bone. Cup designs use varied mechanisms for initial stability in bone; therefore, using different analogues and tests is appropriate. Press-fit cup stability was tested in the following: firstly, polyurethane (PU) foam modelling cancellous support; secondly, glass-fibre reinforced epoxide (GFRE) tubes modelling acetabular cortical support; thirdly, cadaveric acetabula. Three commercial cups [Harris-Galante II (H-G-II), Zimmer; Optifix, Smith & Nephew, Richards; porous coated anatomic (PCA), Howmedica] and an experimental cup with enhanced rim fixation were tested in three modes: direct pull-out, lever-out and axial torque. The fixation stabilities measured in the PU and the GFRE models showed trends consistent with those in cadaver bone, differing in the oversizing and cup geometry. The experimental cup was significantly more secure in most modes than other cups; the H-G II and Optifix cups showed similar stabilities, lower than that of the experimental cup but greater than that of the PCA cup (analysis of variance and Tukey's highly significant test; p < 0.001). The stabilities measured in cadaver bone more closely approximated those in GFRE. The use of several bone analogues enables separation of fixation mechanisms, allowing more accurate prediction of in vivo performance.

  18. Laser/LED phototherapy on the repair of tibial fracture treated with wire osteosynthesis evaluated by Raman spectroscopy.

    PubMed

    Pinheiro, Antônio L B; Soares, Luiz G P; da Silva, Aline C P; Santos, Nicole R S; da Silva, Anna Paula L T; Neves, Bruno Luiz R C; Soares, Amanda P; Silveira, Landulfo

    2018-04-23

    The aim of the present study was to assess, by means of Raman spectroscopy, the repair of complete surgical tibial fractures fixed with wire osteosynthesis (WO) treated or not with infrared laser (λ780 nm) or infrared light emitting diode (LED) (λ850 ± 10 nm) lights, 142.8 J/cm 2 per treatment, associated or not to the use of mineral trioxide aggregate (MTA) cement. Surgical tibial fractures were created on 18 rabbits, and all fractures were fixed with WO and some groups were grafted with MTA. Irradiated groups received lights at every other day during 15 days, and all animals were sacrificed after 30 days, being the tibia removed. The results showed that only irradiation with either laser or LED influenced the peaks of phosphate hydroxyapatite (~ 960 cm -1 ). Collagen (~ 1450 cm -1 ) and carbonated hydroxyapatite (~ 1070 cm -1 ) peaks were influenced by both the use of MTA and the irradiation with either laser or LED. It is concluded that the use of either laser or LED phototherapy associated to MTA cement was efficacious on improving the repair of complete tibial fractures treated with wire osteosynthesis by increasing the synthesis of collagen matrix and creating a scaffold of calcium carbonate (carbonated hydroxyapatite-like) and the subsequent deposition of phosphate hydroxyapatite.

  19. Acetabular revisions using porous tantalum components: A retrospective study with 5-10 years follow-up

    PubMed Central

    Evola, Francesco Roberto; Costarella, Luciano; Evola, Giuseppe; Barchitta, Martina; Agodi, Antonella; Sessa, Giuseppe

    2017-01-01

    AIM To evaluate the clinical and X-ray results of acetabular components and tantalum augments in prosthetic hip revisions. METHODS Fifty-eight hip prostheses with primary failure of the acetabular component were reviewed with tantalum implants. The clinical records and X-rays of these cases were retrospectively reviewed. Bone defect evaluations were based on preoperative CT scans and classified according to Paprosky criteria of Radiolucent lines and periprosthetic gaps; implant mobilization and osteolysis were evaluated by X-ray. An ad hoc database was created and statistical analyses were performed with SPSS software (IBM SPSS Statistics for Windows, version 23.0). Statistical analyses were carried out using the Student’s t test for independent and paired samples. A P value of < 0.05 was considered statistically significant and cumulative survival was calculated by the Kaplan-Meier method. RESULTS The mean follow-up was 87.6 ± 25.6 mo (range 3-120 mo). 25 cases (43.1%) were classified as minor defects, and 33 cases (56.9%) as major defects. The preoperative HHS rating improved significantly from a mean of 40.7 ± 6.1 (range: 29-53) before revision, to a mean of 85.8 ± 6.1 (range: 70-94) at the end of the follow-up (Student’s t test for paired samples: P < 0.001). Considering HHS only at the end of follow-up, no statistically significant difference was observed between patients with a major or minor defect (Student’s t test for independent samples: P > 0.05). Radiolucent lines were found in 4 implants (6.9%). Postoperative acetabular gaps were observed in 5 hips (8.6%). No signs of implant mobilization or areas of periprosthetic osteolysis were found in the x-rays at the final follow-up. Only 3 implants failed: 1 case of infection and 2 cases of instability. Defined as the end-point, cumulative survival at 10 years was 95% (for all reasons) and 100% for aseptic loosening of the acetabular component. CONCLUSION The medium-term use of prosthetic tantalum

  20. Acetabular revisions using porous tantalum components: A retrospective study with 5-10 years follow-up.

    PubMed

    Evola, Francesco Roberto; Costarella, Luciano; Evola, Giuseppe; Barchitta, Martina; Agodi, Antonella; Sessa, Giuseppe

    2017-07-18

    To evaluate the clinical and X-ray results of acetabular components and tantalum augments in prosthetic hip revisions. Fifty-eight hip prostheses with primary failure of the acetabular component were reviewed with tantalum implants. The clinical records and X-rays of these cases were retrospectively reviewed. Bone defect evaluations were based on preoperative CT scans and classified according to Paprosky criteria of Radiolucent lines and periprosthetic gaps; implant mobilization and osteolysis were evaluated by X-ray. An ad hoc database was created and statistical analyses were performed with SPSS software (IBM SPSS Statistics for Windows, version 23.0). Statistical analyses were carried out using the Student's t test for independent and paired samples. A P value of < 0.05 was considered statistically significant and cumulative survival was calculated by the Kaplan-Meier method. The mean follow-up was 87.6 ± 25.6 mo (range 3-120 mo). 25 cases (43.1%) were classified as minor defects, and 33 cases (56.9%) as major defects. The preoperative HHS rating improved significantly from a mean of 40.7 ± 6.1 (range: 29-53) before revision, to a mean of 85.8 ± 6.1 (range: 70-94) at the end of the follow-up (Student's t test for paired samples: P < 0.001). Considering HHS only at the end of follow-up, no statistically significant difference was observed between patients with a major or minor defect (Student's t test for independent samples: P > 0.05). Radiolucent lines were found in 4 implants (6.9%). Postoperative acetabular gaps were observed in 5 hips (8.6%). No signs of implant mobilization or areas of periprosthetic osteolysis were found in the x-rays at the final follow-up. Only 3 implants failed: 1 case of infection and 2 cases of instability. Defined as the end-point, cumulative survival at 10 years was 95% (for all reasons) and 100% for aseptic loosening of the acetabular component. The medium-term use of prosthetic tantalum components in prosthetic hip revisions is

  1. Articular congruity is associated with short-term clinical outcomes of operatively treated SER IV ankle fractures.

    PubMed

    Berkes, Marschall B; Little, Milton T M; Lazaro, Lionel E; Pardee, Nadine C; Schottel, Patrick C; Helfet, David L; Lorich, Dean G

    2013-10-02

    With regard to supination-external rotation type-IV (SER IV) ankle fractures, there is no consensus regarding which patient, injury, and treatment variables most strongly influence clinical outcome. The purpose of this investigation was to examine the impact of articular surface congruity on the functional outcomes of operatively treatment of SER IV ankle fractures. A prospectively generated database consisting of operatively treated SER IV ankle fractures was reviewed. Postoperative computed tomography (CT) scans were used to assess ankle joint congruity. Ankles were considered incongruent in the presence of >2 mm of articular step-off, intra-articular loose bodies, or an articular surface gap of >2 mm (despite an otherwise anatomic reduction) due to joint impaction and comminution. Patients with at least one year of clinical follow-up were eligible for analysis. The primary and secondary outcome measures were the Foot and Ankle Outcome Score (FAOS) and ankle motion. One hundred and eight SER IV fractures met our inclusion criteria. The average duration of follow-up was twenty-one months. Seventy-two patients (67%) had a congruent ankle joint, and thirty-six (33%) had elements of articular surface incongruity on postoperative CT scanning. These two groups were similar with regard to comorbidities and injury and treatment variables. At the time of the final follow-up, the group with articular incongruity had a significantly worse FAOS with regard to symptoms (p = 0.012), pain (p = 0.004), and activities of daily living (p = 0.038). Those with articular incongruity had worse average scores in the FAOS sport domain as well. No significant differences in ankle motion were found between the two groups. In this population of patients with an operatively treated SER IV ankle fracture, the presence of postoperative articular incongruity correlated with inferior early clinical outcomes. Orthopaedic surgeons should scrutinize ankle fracture reductions and strive for

  2. The effect of HIV on early wound healing in open fractures treated with internal and external fixation.

    PubMed

    Aird, J; Noor, S; Lavy, C; Rollinson, P

    2011-05-01

    There are 33 million people worldwide currently infected with human immunodeficiency virus (HIV). This complex disease affects many of the processes involved in wound and fracture healing, and there is little evidence available to guide the management of open fractures in these patients. Fears of acute and delayed infection often inhibit the use of fixation, which may be the most effective way of achieving union. This study compared fixation of open fractures in HIV-positive and -negative patients in South Africa, a country with very high rates of both HIV and high-energy trauma. A total of 133 patients (33 HIV-positive) with 135 open fractures fulfilled the inclusion criteria. This cohort is three times larger than in any similar previously published study. The results suggest that HIV is not a contraindication to internal or external fixation of open fractures in this population, as HIV is not a significant risk factor for acute wound/implant infection. However, subgroup analysis of grade I open fractures in patients with advanced HIV and a low CD4 count (< 350) showed an increased risk of infection; we suggest that grade I open fractures in patients with advanced HIV should be treated by early debridement followed by fixation at an appropriate time.

  3. The treatment of complex proximal humeral fractures: analysis of the results of 55 cases treated with PHILOS plate.

    PubMed

    Fattoretto, D; Borgo, A; Iacobellis, C

    2016-08-01

    Complex proximal humerus fractures are often difficult to treat. Their frequency is high, especially in the elderly, and their treatment is still controversial. The aim of this study was to analyze the clinical and radiological results achieved by patients with complex proximal humerus fractures, treated with PHILOS plate only. A cohort of 55 patients was selected. The mean age was 63.4 (range 33-89), while the mean follow-up time was 21.5 months (range 6-75). Clinical outcome was evaluated with the "Constant-Murley shoulder score." All the informations about the presence of complications were gathered, and radiological images were used to calculate the head-shaft angle. The overall mean Constant score was 61.93 ± 18.59, the Individual CS was 70 ± 20 % and the Relative CS was 83 ± 23 %. No significant differences were found between fractures Neer 3 and Neer 4 and between the surgical approaches (delta-split vs. delto-pectoral). Six patients had a fracture with dislocation, seven patients (12.7 %) had complications while in four patients a head-shaft angle beyond the normal range was found. Osteosynthesis with PHILOS plate is stable in the greater part of the cases, and it allows an earlier rehabilitation and so a good functional result, which could be compromised by a prolonged immobilization. Therefore, PHILOS plate is a good option for the treatment of complex proximal humerus fractures.

  4. Pediatric Facial Fractures: A Review of 2071 Fractures.

    PubMed

    Ferreira, Pedro Costa; Barbosa, Joselina; Braga, José Miguel; Rodrigues, Acácio; Silva, Álvaro Catarino; Amarante, José Manuel

    2016-01-01

    Facial fractures are infrequent in children and adolescents, and there are only few reports that review a significant number of patients. The objective of this study was to analyze the pattern of maxillofacial fractures in pediatric patients of Portugal. We reviewed the clinical records of a series of 1416 patients 18 years or younger with facial fractures, treated by the Department of Plastic Reconstructive, Aesthetic and of Maxillofacial Surgery of São João Hospital, Porto, Portugal, between 1993 and 2012. The following parameters were evaluated: age; sex; cause of the accident; hour, day, and month of hospital admission; location and type of fractures; presence and location of associated injuries; treatment methods; length of in-hospital stay; and complications. A total of 2071 fractures were treated. The ratio of boys to girls was 3.1:1. Patients between 16 and 18 years old were the major group (43.9%). Motor vehicle accident was the most common cause of injuries (48.7% of patients). Mandibular fractures were the most common (44.4%). Associated injuries occurred in 1015 patients (71.7%). Pediatric facial fractures are usually associated with severe trauma. There has been a highly significant decrease (P < 0.001) in pediatric facial fractures in Portugal for the past 20 years.

  5. Endogenous PTH deficiency impairs fracture healing and impedes the fracture-healing efficacy of exogenous PTH(1-34).

    PubMed

    Ren, Yongxin; Liu, Bo; Feng, Yuxu; Shu, Lei; Cao, Xiaojian; Karaplis, Andrew; Goltzman, David; Miao, Dengshun

    2011-01-01

    Although the capacity of exogenous PTH1-34 to enhance the rate of bone repair is well established in animal models, our understanding of the mechanism(s) whereby PTH induces an anabolic response during skeletal repair remains limited. Furthermore it is unknown whether endogenous PTH is required for fracture healing and how the absence of endogenous PTH would influence the fracture-healing capacity of exogenous PTH. Closed mid-diaphyseal femur fractures were created and stabilized with an intramedullary pin in 8-week-old wild-type and Pth null (Pth(-/-)) mice. Mice received daily injections of vehicle or of PTH1-34 (80 µg/kg) for 1-4 weeks post-fracture, and callus tissue properties were analyzed at 1, 2 and 4 weeks post-fracture. Cartilaginous callus areas were reduced at 1 week post-fracture, but were increased at 2 weeks post-fracture in vehicle-treated and PTH-treated Pth(-/-) mice compared to vehicle-treated and PTH-treated wild-type mice respectively. The mineralized callus areas, bony callus areas, osteoblast number and activity, osteoclast number and surface in callus tissues were all reduced in vehicle-treated and PTH-treated Pth(-/-) mice compared to vehicle-treated and PTH-treated wild-type mice, but were increased in PTH-treated wild-type and Pth(-/-) mice compared to vehicle-treated wild-type and Pth(-/-) mice. Absence of endogenous PTH1-84 impedes bone fracture healing. Exogenous PTH1-34 can act in the absence of endogenous PTH but callus formation, including accelerated endochondral bone formation and callus remodeling as well as mechanical strength of the bone are greater when endogenous PTH is present. Results of this study suggest a complementary role for endogenous PTH1-84 and exogenous PTH1-34 in accelerating fracture healing.

  6. Primary stability of a cementless acetabular cup in a cohort of patient-specific finite element models.

    PubMed

    O'Rourke, Dermot; Al-Dirini, Rami Ma; Taylor, Mark

    2018-03-01

    The primary stability achieved during total hip arthroplasty determines the long-term success of cementless acetabular cups. Pre-clinical finite element testing of cups typically use a model of a single patient and assume the results can be extrapolated to the general population. This study explored the variability in predicted primary stability of a Pinnacle ® cementless acetabular cup in 103 patient-specific finite element models of the hemipelvis and examined the association between patient-related factors and the observed variability. Cups were inserted by displacement-control into the FE models and then a loading configuration simulating a complete level gait cycle was applied. The cohort showed a range of polar gap of 284-1112 μm and 95th percentile composite peak micromotion (CPM) of 18-624 μm. Regression analysis was not conclusive on the relationship between patient-related factors and primary stability. No relationship was found between polar gap and micromotion. However, when the patient-related factors were categorised into quartile groups, trends suggested higher polar gaps occurred in subjects with small and shallow acetabular geometries and cup motion during gait was affected most by low elastic modulus and high bodyweight. The variation in primary stability in the cohort for an acetabular cup with a proven clinical track record may provide benchmark data when evaluating new cup designs. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1012-1023, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  7. Study of the three-dimensional orientation of the labrum: its relations with the osseous acetabular rim

    PubMed Central

    Bonneau, Noémie; Bouhallier, July; Baylac, Michel; Tardieu, Christine; Gagey, Olivier

    2012-01-01

    Understanding the three-dimensional orientation of the coxo-femoral joint remains a challenge as an accurate three-dimensional orientation ensure an efficient bipedal gait and posture. The quantification of the orientation of the acetabulum can be performed using the three-dimensional axis perpendicular to the plane that passes along the edge of the acetabular rim. However, the acetabular rim is not regular as an important indentation in the anterior rim was observed. An innovative cadaver study of the labrum was developed to shed light on the proper quantification of the three-dimensional orientation of the acetabulum. Dissections on 17 non-embalmed corpses were performed. Our results suggest that the acetabular rim is better represented by an anterior plane and a posterior plane rather than a single plane along the entire rim as it is currently assumed. The development of the socket from the Y-shaped cartilage was suggested to explain the different orientations in these anterior and posterior planes. The labrum forms a plane that takes an orientation in between the anterior and posterior parts of the acetabular rim, filling up inequalities of the bony rim. The vectors VL, VA2 and VP, representing the three-dimensional orientation of the labrum, the anterior rim and the posterior rim, are situated in a unique plane that appears biomechanically dependent. The three-dimensional orientation of the acetabulum is a fundamental parameter to understand the hip joint mechanism. Important applications for hip surgery and rehabilitation, as well as for physical anthropology, were discussed. PMID:22360458

  8. Vibration Testing Procedures for Bone Stiffness Assessment in Fractures Treated with External Fixation.

    PubMed

    Mattei, Lorenza; Longo, Antonia; Di Puccio, Francesca; Ciulli, Enrico; Marchetti, Stefano

    2017-04-01

    A bone healing assessment is crucial for the successful treatment of fractures, particularly in terms of the timing of support devices. However, in clinical practice, this assessment is only made qualitatively through bone manipulation and X-rays, and hence cannot be repeated as often as might be required. The present study reconsiders the quantitative method of frequency response analysis for healing assessments, and specifically for fractures treated with an external fixator. The novelty consists in the fact that bone excitation and response are achieved through fixator pins, thus overcoming the problem of transmission through soft-tissues and their damping effect. The main objective was to develop and validate a test procedure in order to characterize the treated bone. More than 80 tests were performed on a tibia phantom alone, a phantom with pins, and a phantom with a complete fixator. Different excitation techniques and input-output combinations were compared. The results demonstrated the effectiveness of a procedure based on impact tests using a micro-hammer. Pins and fixator were demonstrated to influence the frequency response of the phantom by increasing the number of resonant frequencies. This procedure will be applied in future studies to monitor healing both in in vitro and in vivo conditions.

  9. Complications in the treatment of adolescent clavicle fractures.

    PubMed

    Luo, T David; Ashraf, Ali; Larson, A Noelle; Stans, Anthony A; Shaughnessy, William J; McIntosh, Amy L

    2015-04-01

    This study evaluated the complications associated with the treatment of clavicle fractures in adolescents. All cases of clavicle fractures were identified during an 8-year period between January 2005 and January 2013. During the study period, 153 clavicle fractures occurred in patients between the ages of 14 and 17 years who were treated at the authors' center. Medical records and radiographs were reviewed to determine injury mechanism, fracture pattern, treatment, and complications. Injury severity was assessed as high, medium, and low. Patients with medial or distal metaphyseal fractures and intra-articular fractures were excluded. Of the 153 clavicle fractures, 23 (15.0%) were treated surgically. Compared with the fractures treated nonsurgically, the surgical fractures had greater shortening (mean, 2.0 vs 0.9 cm; P<.001) and were more likely to be comminuted (65.2% vs 23.1%; P<.001). Complications occurred in 21.7% of fractures treated surgically, including refracture (n=2), implant removal for prominence (n=2), and nonunion with implant failure (n=1). One complication was associated with intramedullary nailing, whereas the other 4 complications occurred in clavicles treated with plate fixation. In the non-surgical group, no patients sustained a refracture or malunion who required delayed surgical intervention. Pediatric fellowship-trained orthopedic surgeons treated 78 displaced fractures, resulting in 8 (10.3%) surgeries. Nonpediatric orthopedic specialists treated 46 displaced fractures, 15 (32.6%) of which were treated surgically (P=.0035). Copyright 2015, SLACK Incorporated.

  10. Fracture strength of endodontically treated molars transfixed horizontally by a fiber glass post.

    PubMed

    Beltrão, Maria Cecilia Gomes; Spohr, Ana Maria; Oshima, Hugo Mitsuo Silva; Mota, Eduardo Gonçalves; Burnett, Luiz Henrique

    2009-02-01

    To assess the effect of a horizontally transfixed fiber glass post placed between buccal and palatal surfaces, on the fracture strength of endodontically treated molar teeth with MOD cavities, either restored with resin-based composite, or not. 75 sound maxillary human third molars were extracted, embedded in acrylic resin blocks and randomly assigned to five groups (n=15). Group A (sound teeth), (control) and Groups B, C, D and E, which were subjected to the following procedures after endodontic treatment: GB--(MOD+Endo), GC--(MOD+Endo+Post), GD--MOD and composite restoration (MOD+Endo+CR), GE--(MOD+Endo+Post+CR). The specimens were stored in distilled water at 37 degrees C for 24 hours. Later, a compressive force was applied by means of a universal testing machine at 1 mm/minute speed, parallel to the long axis of the teeth until fracture occurred. The means of the results (N) followed by the same letter represent no statistical difference by ANOVA and Tukey (P<0.05): GA = 4289.8 (+/- 1128.9)a, GB = 549.6 (+/- 120.7)b, GC = 1474.8 (+/- 338.1)c, GD = 1224.7 (+/- 236.0)c, GE = 2645.4 (+/- 675.1)d. In the analysis of qualitative variables, there was a tendency to cusp fracture in all groups except for Group C. The fiber glass post transfixed horizontally in a MOD cavity significantly increased the fracture resistance of the teeth restored with resin composite.

  11. Change in Acetabular Cup Orientation From Supine to Standing Position and Its Effect on Wear of Highly Crosslinked Polyethylene.

    PubMed

    Teeter, Matthew G; Goyal, Prateek; Yuan, Xunhua; Howard, James L; Lanting, Brent A

    2018-01-01

    The purpose of this study is to measure acetabular cup position and wear of the highly crosslinked polyethylene liner in the supine and standing position for patients at a minimum of 10 years after the operation. A total of 38 patients were recruited at a mean of 12.5 years after the operation. All patients received a single acetabular cup design with a highly crosslinked liner and a 28-mm cobalt-chromium femoral head. Patients underwent supine and standing radiostereometric examinations in which the X-ray sources and detectors were positioned to obtain an anterior-posterior and cross-table lateral radiograph. Acetabular cup position and the three-dimensional wear rate were measured from the radiographs, and outcome scores were recorded for each patient. Anteversion significantly increased (P < .0001) a mean of 12° from supine (15.1° ± 10.4°) to standing (27.2° ± 10.5°) position. Inclination also significantly increased (P = .001) a mean of 2° from supine (44.4° ± 6.8°) to standing (46.3° ± 7.7°) position. There was no difference (P = .093) in wear rate between supine (0.067 ± 0.070 mm/y) and standing (0.073 ± 0.074 mm/y) positions. There were no correlations between cup orientation and wear rate in either position. Highly crosslinked polyethylene is a forgiving bearing material. Although adherence to the traditional acetabular position target zone is recommended, ensuring hip stability and consideration of the patient's functional position are also important objectives to consider for the acetabular position. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Complications in the Treatment of Adolescent Clavicle Fractures

    PubMed Central

    Luo, T. David; Ashraf, Ali; Larson, A. Noelle; Stans, Anthony A.; Shaughnessy, William J.; McIntosh, Amy L.

    2015-01-01

    The authors’ study evaluates the complications associated with the treatment of clavicle fractures in adolescents. During the study period, 153 clavicle fractures occurred in patients between the ages of 14 and 17 years who were treated at the authors’ center, of which 23 (15.0%) were treated surgically. Compared to the fractures treated nonoperatively, the surgical fractures had greater shortening (mean, 2.0 vs 0.9 cm; P<.001) and were more likely to be comminuted (65.2% vs 23.1%; P<.001). Complications occurred in 21.7% of fractures treated surgically. One delayed union occurred in the nonoperative cohort, but no other complications or patients who required clavicular osteotomy for malunion. Pediatric fellowship-trained orthopedic surgeons treated 78 displaced fractures, resulting in 8 (10.3%) surgeries. Nonpediatric orthopedic specialists treated 46 displaced fractures, 15 (32.6%) of which were treated operatively (P=.0035). FigureA 15-year-old boy sustained a comminuted clavicle fracture from playing football. Preoperative radiograph showing significant clavicle shortening and a vertical fragment. PMID:25901621

  13. The relationship between operative and radiographic acetabular component orientation: which factors influence resultant cup orientation?

    PubMed

    Grammatopoulos, G; Pandit, H G; da Assunção, R; McLardy-Smith, P; De Smet, K A; Gill, H S; Murray, D W

    2014-10-01

    There is great variability in acetabular component orientation following hip replacement. The aims of this study were to compare the component orientation at impaction with the orientation measured on post-operative radiographs and identify factors that influence the difference between the two. A total of 67 hip replacements (52 total hip replacements and 15 hip resurfacings) were prospectively studied. Intra-operatively, the orientation of the acetabular component after impaction relative to the operating table was measured using a validated stereo-photogrammetry protocol. Post-operatively, the radiographic orientation was measured; the mean inclination/anteversion was 43° (sd 6°)/ 19° (sd 7°). A simulated radiographic orientation was calculated based on how the orientation would have appeared had an on-table radiograph been taken intra-operatively. The mean difference between radiographic and intra-operative inclination/anteversion was 5° (sd 5°)/ -8° (sd 8°). The mean difference between simulated radiographic and intra-operative inclination/anteversion, which quantifies the effect of the different way acetabular orientation is measured, was 3°/-6° (sd 2°). The mean difference between radiographic and simulated radiographic orientation inclination/anteversion, which is a manifestation of the change in pelvic position between component impaction and radiograph, was 1°/-2° (sd 7°). This study demonstrated that in order to achieve a specific radiographic orientation target, surgeons should implant the acetabular component 5° less inclined and 8° more anteverted than their target. Great variability (2 sd about ± 15°) in the post-operative radiographic cup orientation was seen. The two equally contributing causes for this are variability in the orientation at which the cup is implanted, and the change in pelvic position between impaction and post-operative radiograph. ©2014 The British Editorial Society of Bone & Joint Surgery.

  14. Treatment of mandibular symphyseal fracture combined with dislocated intracapsular condylar fractures.

    PubMed

    Xu, Xiaofeng; Shi, Jun; Xu, Bing; Dai, Jiewen; Zhang, Shilei

    2015-03-01

    To evaluate the treatment methods of mandibular symphyseal fracture combined with dislocated intracapsular condylar fractures (MSF&DICF) and to compare the effect of different treatment methods of condylar fractures. Twenty-eight patients with MSF&DICF were included in this study. Twenty-two sites were treated by open reduction, and all the medial condylar fragments were fixed with titanium screws; whereas the other 22 sites underwent close treatment. The surgical effect between these 2 groups was compared based on clinical examination and radiographic examination results. Seventeen of 22 condyle fractures were repositioned in the surgery group, whereas 4 of 22 condyle fractures were repositioned in the close treatment group. Statistical difference was observed between these 2 groups (P < 0.01). Functional outcomes of the patients treated in the surgical treatment group also were better than those in the close treatment group. The dislocated intracapsular condyle fractures should be treated by surgical reduction with the maintenance of the attachment of lateral pterygoid muscle, which is beneficial to repositioning the dislocated condyle to its original physiological position, to closure of the mandibular lingual gap, to restore the mandibular width.

  15. Morphological experimental study of bone stress at the interface acetabular bone/prosthetic cup in the bipolar hip prosthesis.

    PubMed

    Anuşca, D; Pleşea, I E; Iliescu, N; Tomescu, P; Poenaru, F; Dascălu, V; Pop, O T

    2006-01-01

    By calculating the tension and distortion of the elements composing the bipolar prosthesis under extreme conditions encountered in real life using a special post-processing program, we established the variation curves of the contact pressure at the hip bone-cup, armor-cup and cup-femoral head interface. By comparing the data obtained from all the examined cases, important conclusions were drawn regarding the influence of tension and pressure distribution on the structural integrity and biomechanics of the prosthesis, as well as the acetabular wear and tear, in order to assess its reliability. The experimentally determined tension and distortion status at the acetabular bone-metal armour interface, lead to the wear and tear phenomenon, which can be explained by three mechanisms and theories incompletely reflecting the overall process. The histopathologic study of the acetabular bone tissue using FEM (finite elements method) on surgically removed specimens will probably lead to the identification of a series of factors that could reduce the rate of the wear and tear process.

  16. Femoral Neck Fractures in Adults Treated With Internal Fixation: A Prospective Multicenter Chinese Cohort.

    PubMed

    Slobogean, Gerard P; Stockton, David J; Zeng, Bingfang; Wang, Dong; Ma, Bao-Tong; Pollak, Andrew N

    2017-04-01

    Although femoral neck fractures in young patients are rare and their complications are well-documented, there is a paucity of data on patient-reported outcomes for this population. The purpose of this study was to describe the quality of life and the effect of clinical complications on the outcomes of young patients with femoral neck fractures in a Chinese cohort. In this prospective observational cohort study, patients aged 18 to 55 years admitted to one of three participating trauma hospitals in China for treatment of a femoral neck fracture were recruited. The primary outcome was the patient's health-related quality of life using the Medical Outcomes Study 36-Item Short Form (SF-36) Health Survey at 1 year after injury. Associations between the primary outcome and potential predictors were explored with univariate and multivariate regression analysis. One hundred seven patients (mean age, 44 years) completed 1-year follow-up. Nearly all patients were treated with closed reduction and screw fixation. Nine cases of nonunion, 7 cases of malunion, and 11 cases of osteonecrosis were identified. The mean SF-36 Physical Component Score was 48.6 ± 8.5, and the mean Mental Component Score was 51.0 ± 7.4. Fracture displacement, quality of reduction, and nonunion were associated with a poor Physical Component Score outcome. Our results demonstrate that the quality of life for patients after closed reduction and screw fixation of femoral neck fractures is similar to that of the general population, particularly when complications of nonunion and malunion are avoided. Level I.

  17. Towards the optimal design of an uncemented acetabular component using genetic algorithms

    NASA Astrophysics Data System (ADS)

    Ghosh, Rajesh; Pratihar, Dilip Kumar; Gupta, Sanjay

    2015-12-01

    Aseptic loosening of the acetabular component (hemispherical socket of the pelvic bone) has been mainly attributed to bone resorption and excessive generation of wear particle debris. The aim of this study was to determine optimal design parameters for the acetabular component that would minimize bone resorption and volumetric wear. Three-dimensional finite element models of intact and implanted pelvises were developed using data from computed tomography scans. A multi-objective optimization problem was formulated and solved using a genetic algorithm. A combination of suitable implant material and corresponding set of optimal thicknesses of the component was obtained from the Pareto-optimal front of solutions. The ultra-high-molecular-weight polyethylene (UHMWPE) component generated considerably greater volumetric wear but lower bone density loss compared to carbon-fibre reinforced polyetheretherketone (CFR-PEEK) and ceramic. CFR-PEEK was located in the range between ceramic and UHMWPE. Although ceramic appeared to be a viable alternative to cobalt-chromium-molybdenum alloy, CFR-PEEK seems to be the most promising alternative material.

  18. Fracture resistance of structurally compromised and normal endodontically treated teeth restored with different post systems: An in vitro study

    PubMed Central

    Mortazavi, Vajihesadat; Fathi, Mohammadhossein; Katiraei, Najmeh; Shahnaseri, Shirin; Badrian, Hamid; Khalighinejad, Navid

    2012-01-01

    Background: With the aim of developing methods that could increase the fracture resistance of structurally compromised endodontically treated teeth, this study was conducted to compare the effect of three esthetic post systems on the fracture resistance and failure modes of structurally compromised and normal roots. Materials and Methods: Forty five extracted and endodontically treated maxillary central teeth were assigned to 5 experimental groups (n=9). In two groups, the post spaces were prepared with the corresponding drills of the post systems to be restored with double taper light posts (DT.Light-Post) (group DT.N) and zirconia posts (Cosmopost) (group Zr.N). In other 3 groups thin wall canals were simulated to be restored with Double taper Light posts (DT.W), double taper Light posts and Ribbond fibers (DT+R.W) and Zirconia posts (Zr.W). After access cavity restoration and thermocycling, compressive load was applied and the fracture strength values and failure modes were evaluated. Data were analyzed using two-way ANOVA, Tukey and Fisher exact tests (P<0.05). Results: The mean failure loads (N) were 678.56, 638.22, 732.44, 603.44 and 573.67 for groups DT.N, Zr.N, DT.W, DT+R.W and Zr.w respectively. Group DT+R.W exhibited significantly higher resistance to fracture compared to groups Zr.N, DT.W and Zr.w (P<0.05). A significant difference was detected between groups DT.N and Zr.W (P=0.027). Zirconia posts showed significantly higher root fracture compared to fiber posts (P=0.004). Conclusion: The structurally compromised teeth restored with double taper light posts and Ribbond fibers showed the most fracture resistance and their strengths were comparable to those of normal roots restored with double taper light posts. More desirable fracture patterns were observed in teeth restored with fiber posts. PMID:22623936

  19. [Efficacy of Sacroiliac Joint Anterior Approach with Double Reconstruction Plate and Computer Assisted Navigation Percutaneous Sacroiliac Screw for Treating Tile C1 Pelvic Fractures].

    PubMed

    Tan, Zhen; Fang, Yue; Zhang, Hui; Liu, Lei; Xiang, Zhou; Zhong, Gang; Huang, Fu-Guo; Wang, Guang-Lin

    2017-09-01

    To compare the efficacy of sacroiliac joint anterior approach with double reconstruction plate and computer assisted navigation percutaneous sacroiliac screw for treating Tile C1 pelvic fractures. Fifty patients with pelvic Tile C1 fractures were randomly divided into two groups ( n =25 for each) in the orthopedic department of West China Hospital of Sichuan University from December 2012 to November 2014. Patients in group A were treated by sacroiliac joint dislocation with anterior plate fixation. Patients in group B were treated with computerized navigation for percutaneous sacroiliac screw. The operation duration,intraoperative blood loss,incision length,and postoperative complications (nausea,vomiting,pulmonary infection,wound complications,etc.) were compared between the two groups. The postoperative fracture healing time,postoperative patient satisfaction,and postoperative fractures MATTA scores (to evaluate fracture reduction),postoperative MAJEED function scores,and SF36 scores of the patients were also recorded and compared. No significant differences in baseline characteristics were found between the two groups of patients. All of the patients in both groups had their operations successfully completed. Patients in group B had significantly shorter operations and lower intraoperative blood loss,incision length and postoperative complications than those in group A ( P <0.05). Patients in group B also had higher levels of satisfaction than those in group A ( P <0.05). No significant differences were found between the two groups in postoperative followup time,fracture healing time,postoperative MATTA scores,postoperative MAJEED function scores and SF36 scores ( P >0.05). Sacroiliac joint anterior approach with double reconstruction plate and computer assisted navigation percutaneous sacroiliac screws are both effective for treating Tile C1type pelvic fractures,with similar longterm efficacies. However,computer assisted navigation percutaneous sacroiliac screw

  20. Atypical fracture with long-term bisphosphonate therapy is associated with altered cortical composition and reduced fracture resistance

    PubMed Central

    Lloyd, Ashley A.; Gludovatz, Bernd; Riedel, Christoph; Luengo, Emma A.; Saiyed, Rehan; Marty, Eric; Lorich, Dean G.; Lane, Joseph M.; Ritchie, Robert O.

    2017-01-01

    Bisphosphonates are the most widely prescribed pharmacologic treatment for osteoporosis and reduce fracture risk in postmenopausal women by up to 50%. However, in the past decade these drugs have been associated with atypical femoral fractures (AFFs), rare fractures with a transverse, brittle morphology. The unusual fracture morphology suggests that bisphosphonate treatment may impair toughening mechanisms in cortical bone. The objective of this study was to compare the compositional and mechanical properties of bone biopsies from bisphosphonate-treated patients with AFFs to those from patients with typical osteoporotic fractures with and without bisphosphonate treatment. Biopsies of proximal femoral cortical bone adjacent to the fracture site were obtained from postmenopausal women during fracture repair surgery (fracture groups, n = 33) or total hip arthroplasty (nonfracture groups, n = 17). Patients were allocated to five groups based on fracture morphology and history of bisphosphonate treatment [+BIS Atypical: n = 12, BIS duration: 8.2 (3.0) y; +BIS Typical: n = 10, 7.7 (5.0) y; +BIS Nonfx: n = 5, 6.4 (3.5) y; −BIS Typical: n = 11; −BIS Nonfx: n = 12]. Vibrational spectroscopy and nanoindentation showed that tissue from bisphosphonate-treated women with atypical fractures was harder and more mineralized than that from bisphosphonate-treated women with typical osteoporotic fractures. In addition, fracture mechanics measurements showed that tissue from patients treated with bisphosphonates had deficits in fracture toughness, with lower crack-initiation toughness and less crack deflection at osteonal boundaries than that of bisphosphonate-naïve patients. Together, these results suggest a deficit in intrinsic and extrinsic toughening mechanisms, which contribute to AFFs in patients treated with long-term bisphosphonates. PMID:28760963

  1. T2* Mapping Provides Information That Is Statistically Comparable to an Arthroscopic Evaluation of Acetabular Cartilage.

    PubMed

    Morgan, Patrick; Nissi, Mikko J; Hughes, John; Mortazavi, Shabnam; Ellerman, Jutta

    2017-07-01

    Objectives The purpose of this study was to validate T2* mapping as an objective, noninvasive method for the prediction of acetabular cartilage damage. Methods This is the second step in the validation of T2*. In a previous study, we established a quantitative predictive model for identifying and grading acetabular cartilage damage. In this study, the model was applied to a second cohort of 27 consecutive hips to validate the model. A clinical 3.0-T imaging protocol with T2* mapping was used. Acetabular regions of interest (ROI) were identified on magnetic resonance and graded using the previously established model. Each ROI was then graded in a blinded fashion by arthroscopy. Accurate surgical location of ROIs was facilitated with a 2-dimensional map projection of the acetabulum. A total of 459 ROIs were studied. Results When T2* mapping and arthroscopic assessment were compared, 82% of ROIs were within 1 Beck group (of a total 6 possible) and 32% of ROIs were classified identically. Disease prediction based on receiver operating characteristic curve analysis demonstrated a sensitivity of 0.713 and a specificity of 0.804. Model stability evaluation required no significant changes to the predictive model produced in the initial study. Conclusions These results validate that T2* mapping provides statistically comparable information regarding acetabular cartilage when compared to arthroscopy. In contrast to arthroscopy, T2* mapping is quantitative, noninvasive, and can be used in follow-up. Unlike research quantitative magnetic resonance protocols, T2* takes little time and does not require a contrast agent. This may facilitate its use in the clinical sphere.

  2. Acetabular revision with impaction bone grafting and a cemented polyethylene acetabular component: comparison of the Kaplan-Meier analysis to the competing risk analysis in 62 revisions with 25 to 30 years follow-up.

    PubMed

    Te Stroet, M A J; Keurentjes, J C; Rijnen, W H C; Gardeniers, J W M; Verdonschot, N; Slooff, T J J H; Schreurs, B W

    2015-10-01

    We present the results of 62 consecutive acetabular revisions using impaction bone grafting and a cemented polyethylene acetabular component in 58 patients (13 men and 45 women) after a mean follow-up of 27 years (25 to 30). All patients were prospectively followed. The mean age at revision was 59.2 years (23 to 82). We performed Kaplan-Meier (KM) analysis and also a Competing Risk (CR) analysis because with long-term follow-up, the presence of a competing event (i.e. death) prevents the occurrence of the endpoint of re-revision. A total of 48 patients (52 hips) had died or had been re-revised at final review in March 2011. None of the deaths were related to the surgery. The mean Harris hip score of the ten surviving hips in ten patients was 76 points (45 to 99). The KM survivorship at 25 years for the endpoint 're-revision for any reason' was 58.0% (95% confidence interval (CI) 38 to 73) and for 're-revision for aseptic loosening' 72.1% (95% CI 51 to 85). With the CR analysis we calculated the KM analysis overestimates the failure rate with respectively 74% and 93% for these endpoints. The current study shows that acetabular impaction bone grafting revisions provide good clinical results at over 25 years. ©2015 The British Editorial Society of Bone & Joint Surgery.

  3. High complication rate in reconstruction of Paprosky type IIIa acetabular defects using an oblong implant with modular side plates and a hook.

    PubMed

    Babis, G C; Sakellariou, V I; Chatziantoniou, A N; Soucacos, P N; Megas, P

    2011-12-01

    We report the results of 62 hips in 62 patients (17 males, 45 females) with mean age of 62.4 years (37 to 81), who underwent revision of the acetabular component of a total hip replacement due to aseptic loosening between May 2003 and November 2007. All hips had a Paprosky type IIIa acetabular defect. Acetabular revision was undertaken using a Procotyl E cementless oblong implant with modular side plates and a hook combined with impaction allografting. At a mean follow-up of 60.5 months (36 to 94) with no patients lost to follow-up and one died due to unrelated illness, the complication rate was 38.7%. Complications included aseptic loosening (19 hips), deep infection (3 hips), broken hook and side plate (one hip) and a femoral nerve palsy (one hip). Further revision of the acetabular component was required in 18 hips (29.0%) and a further four hips (6.4%) are currently loose and awaiting revision. We observed unacceptably high rates of complication and failure in our group of patients and cannot recommend this implant or technique.

  4. Functional and radiological evaluations of high-energy tibial plateau fractures treated with double-buttress plate fixation.

    PubMed

    Yu, Z; Zheng, L; Zhang, Y; Li, J; Ma, Bao'an

    2009-05-14

    This study was designed to evaluate the functional and radiological outcomes of patients with complex tibial plateau fractures treated with double-buttress plate fixation. Sixty five cases of complex (Schatzker type V and VI) tibial plateau fractures were treated with double-buttress plate fixation in our centre from September 2001 to September 2006 through two separate plate incisions. Fifty four patients were followed up for a period ranging from 12 to 48 months and evaluated for the functional and radiological outcomes by a series of standard questionnaire and measurement. Due to the good exposure without any extensive soft-tissue dissection of the double-buttress plate fixation, the fractures in all 54 patients were healed and the treatment achieved greater than 90% of satisfactory-to-excellent rates of reduction. The mean time of bone union was 15.4 weeks (range, 12-30 weeks), and the mean time of full weight-bearing was 18.7 weeks (range, 14-26 weeks). At the final follow-up visit, no patients showed knee instability; the mean range of motion was 107.6 degrees (range, 85 degrees -130 degrees ). For all patients, no statistically significant difference in the functional outcomes was observed between their 6-months and final follow-up visits; or in the radiological findings between their immediate postoperative and final follow-up examinations. Double-buttress plate fixation is a feasible treatment option for bilcondylar and complex tibial plateau fractures. Although technically demanding, it offers reliable stability without additional postoperative adjuvant external fixation, and at the same time avoids extensive soft tissue dissection, allowing the early painless range of motion.

  5. The effect of the Tscherne injury pattern on the outcome of operatively treated Lisfranc fracture dislocations.

    PubMed

    Demirkale, Ismail; Tecimel, Osman; Celik, Ismail; Kilicarslan, Kasim; Ocguder, Ali; Dogan, Metin

    2013-09-01

    Lisfranc fracture dislocations cause severe tarso-metatarsal malalignment. The research question of this study was to evaluate the severity of the soft tissue injury on the final clinical outcome and compare that with the effect of various determinants on the disability in daily living activities after open reduction and internal fixation of a Lisfranc injury. This study consisted of a retrospective analysis of patients with Lisfranc fracture dislocations who were treated by open reduction and internal fixation beween 2004 and 2009. Evaluation focused mainly on the severity of the soft tissue injury, age, fracture classification, time to operation, posttraumatic osteoarthritis, and the results were compared with American Foot and Ankle Society (AOFAS) scores, and Foot and Ankle Disability Index (FADI). Eight patients had Tscherne Grade 1, 13 had Grade 2, and 11 had Grade 3 soft tissue injuries. Myerson classification revealed 11 type A, 8 type B and 13 type C fractures. Six patients' operations were delayed beyond 8h. Of the 38 patients treated in the study period, 32 patients (11 female, 21 male; <30 y-old: 14, >30 y-old: 18) were available for complete follow-up (average, 55.5 months). The comparison of treatment results revealed that those patients with high grade soft tissue injuries had lower AOFAS and FADI scores (43.8±15.9, 53.7±9.4, respectively) when compared to Tscherne Grade 1 injuries (82.8±6.1, 109±13.9, respectively) (p<0.001). The overall negative impact of the severity of soft tissue injury on functional outcomes had similar significance with regard to post-traumatic osteoarthritis, and fracture type. There was also a statistically significant difference between outcome measures and post-reduction quality (p=0.002). Patient age (p=0.9) and delayed surgery (p=0.5) had no statistically significant effect on the final outcome. Satisfactory results can be achieved with open reduction for Lisfranc injuries. However, despite this treatment, both the

  6. [Pulsative hematoma--a penile fracture complication].

    PubMed

    Dorde, Nale; Mićić, Sava

    2007-01-01

    Fracture of the penis is a direct blunt trauma of the erect or semi-erect penis. It can be treated by conservative or surgical means. Retrospective analyses of conservative penile fracture treatment reveal frequent immediate and later complications. We presented a 41-year-old patient with pulsative hematoma caused by an unusual fracture of the penis. Fracture had appeared 40 days before the admittance during a sexual intercourse. The patient was treated surgically. Pulsative hematoma (pulsative diverticulum) is a very rare, early complication of a conservatively treated penile fracture. Surgical treatment has an advantage over surgical one, which was confirmed by our case report.

  7. Use of iPhone technology in improving acetabular component position in total hip arthroplasty.

    PubMed

    Tay, Xiau Wei; Zhang, Benny Xu; Gayagay, George

    2017-09-01

    Improper acetabular cup positioning is associated with high risk of complications after total hip arthroplasty. The aim of our study is to objectively compare 3 methods, namely (1) free hand, (2) alignment jig (Sputnik), and (3) iPhone application to identify an easy, reproducible, and accurate method in improving acetabular cup placement. We designed a simple setup and carried out a simple experiment (see Method section). Using statistical analysis, the difference in inclination angles using iPhone application compared with the freehand method was found to be statistically significant ( F [2,51] = 4.17, P = .02) in the "untrained group". There is no statistical significance detected for the other groups. This suggests a potential role for iPhone applications in junior surgeons in overcoming the steep learning curve.

  8. Effects of the Ratio between Pigment and Bleaching Gel on the Fracture Resistance and Dentin Microhardness of endodontically treated Teeth.

    PubMed

    Galloza, Marina Og; Jordão-Basso, Keren Cf; Bandeca, Matheus C; Costa, Samuel O; Borges, Alvaro H; Tonetto, Mateus R; Tirintan, Fabio C; Keine, Kátia C; Kuga, Milton C

    2017-11-01

    The aim of this study was to evaluate the effects of bleaching gel using 35% hydrogen peroxide (HP), associated with red carmine pigment (RC), in the 3:1 or 1:1 ratio, on fracture resistance and dentin microhardness of endodontically treated teeth. A total of 40 lower incisors were endodontically treated and divided into four groups (n = 10), according to the bleaching protocol: G1 (HP3), 35% HP + RC (3:1); G2 (HP1), 35% HP + RC (1:1); G3 (positive), 38% HP; and G4 (negative), unbleached. Four dental bleaching sessions were performed. The dental crowns were restored after the last session and submitted to the fracture resistance test. Totally, 60 specimens from the endodontically treated lower incisor crowns were prepared to evaluate the effects on dentin microhardness. The analysis was measured (in Knoop) prior to and after the last dental bleaching session using similar bleaching protocols. G2 presented the lowest fracture resistance (p < 0.05). The other groups were similar to each other (p > 0.05). No difference was observed in the reduction of dentin microhardness among the groups (p > 0.05). A 1:1 ratio (bleaching gel:pigment) caused a significant fracture resistance reduction in relation to the other protocols. No effect on the dentin microhardness reduction was observed. The pigment addition to the bleaching agent accelerates the bleaching chemical reaction. However, no studies have evaluated the ideal proportion to optimize tooth bleaching.

  9. Fracture resistance of endodontically treated teeth restored with Zirconia filler containing composite core material and fiber posts.

    PubMed

    Jeaidi, Zaid Al

    2016-01-01

    To assess the fracture resistance of endodontically treated teeth with a novel Zirconia (Zr) nano-particle filler containing bulk fill resin composite. Forty-five freshly extracted maxillary central incisors were endodontically treated using conventional step back preparation and warm lateral condensation filling. Post space preparation was performed using drills compatible for fiber posts (Rely X Fiber Post) on all teeth (n=45), and posts were cemented using self etch resin cement (Rely X Unicem). Samples were equally divided into three groups (n=15) based on the type of core materials, ZirconCore (ZC) MulticCore Flow (MC) and Luxacore Dual (LC). All specimens were mounted in acrylic resin and loads were applied (Universal testing machine) at 130° to the long axis of teeth, at a crosshead speed of 0.5 mm/min until failure. The loads and the site at which the failures occurred were recorded. Data obtained was tabulated and analyzed using a statistical program. The means and standard deviations were compared using ANOVA and Multiple comparisons test. The lowest and highest failure loads were shown by groups LC (18.741±3.02) and MC (25.16±3.30) respectively. Group LC (18.741±3.02) showed significantly lower failure loads compared to groups ZC (23.02±4.21) and MC (25.16±3.30) (p<0.01). However groups ZC (23.02±4.21) and MC (25.16±3.30) showed comparable failure loads (p=0.23). Fracture resistance of endodontically treated teeth restored with Zr filler containing bulk fill composite cores was comparable to teeth restored with conventional Zr free bulk fill composites. Zr filled bulk fill composites are recommended for restoration of endodontically treated teeth as they show comparable fracture resistance to conventional composite materials with less catastrophic failures.

  10. Bone fractures among postmenopausal patients with endocrine-responsive early breast cancer treated with 5 years of letrozole or tamoxifen in the BIG 1-98 trial.

    PubMed

    Rabaglio, M; Sun, Z; Price, K N; Castiglione-Gertsch, M; Hawle, H; Thürlimann, B; Mouridsen, H; Campone, M; Forbes, J F; Paridaens, R J; Colleoni, M; Pienkowski, T; Nogaret, J-M; Láng, I; Smith, I; Gelber, R D; Goldhirsch, A; Coates, A S

    2009-09-01

    To compare the incidence and timing of bone fractures in postmenopausal women treated with 5 years of adjuvant tamoxifen or letrozole for endocrine-responsive early breast cancer in the Breast International Group (BIG) 1-98 trial. We evaluated 4895 patients allocated to 5 years of letrozole or tamoxifen in the BIG 1-98 trial who received at least some study medication (median follow-up 60.3 months). Bone fracture information (grade, cause, site) was collected every 6 months during trial treatment. The incidence of bone fractures was higher among patients treated with letrozole [228 of 2448 women (9.3%)] versus tamoxifen [160 of 2447 women (6.5%)]. The wrist was the most common site of fracture in both treatment groups. Statistically significant risk factors for bone fractures during treatment included age, smoking history, osteoporosis at baseline, previous bone fracture, and previous hormone replacement therapy. Consistent with other trials comparing aromatase inhibitors to tamoxifen, letrozole was associated with an increase in bone fractures. Benefits of superior disease control associated with letrozole and lower incidence of fracture with tamoxifen should be considered with the risk profile for individual patients.

  11. Bone fractures among postmenopausal patients with endocrine-responsive early breast cancer treated with 5 years of letrozole or tamoxifen in the BIG 1-98 trial

    PubMed Central

    Rabaglio, M.; Sun, Z.; Castiglione-Gertsch, M.; Hawle, H.; Thürlimann, B.; Mouridsen, H.; Campone, M.; Forbes, J. F.; Paridaens, R. J.; Colleoni, M.; Pienkowski, T.; Nogaret, J.-M.; Láng, I.; Smith, I.; Gelber, R. D.; Goldhirsch, A.; Coates, A. S.

    2009-01-01

    Background: To compare the incidence and timing of bone fractures in postmenopausal women treated with 5 years of adjuvant tamoxifen or letrozole for endocrine-responsive early breast cancer in the Breast International Group (BIG) 1-98 trial. Methods: We evaluated 4895 patients allocated to 5 years of letrozole or tamoxifen in the BIG 1-98 trial who received at least some study medication (median follow-up 60.3 months). Bone fracture information (grade, cause, site) was collected every 6 months during trial treatment. Results: The incidence of bone fractures was higher among patients treated with letrozole [228 of 2448 women (9.3%)] versus tamoxifen [160 of 2447 women (6.5%)]. The wrist was the most common site of fracture in both treatment groups. Statistically significant risk factors for bone fractures during treatment included age, smoking history, osteoporosis at baseline, previous bone fracture, and previous hormone replacement therapy. Conclusions: Consistent with other trials comparing aromatase inhibitors to tamoxifen, letrozole was associated with an increase in bone fractures. Benefits of superior disease control associated with letrozole and lower incidence of fracture with tamoxifen should be considered with the risk profile for individual patients. PMID:19474112

  12. Examination and treatment of a professional ballet dancer with a suspected acetabular labral tear: A case report.

    PubMed

    Khoo-Summers, Lynnette; Bloom, Nancy J

    2015-08-01

    Dancers are at risk for developing groin pain that is due to acetabular labral tears. Although surgical management of labral tears has been reported extensively, conservative management has been poorly described. This case report describes the examination, diagnosis, and treatment of groin pain in a professional ballet dancer with a suspected acetabular labral tear. Treatment focused on decreasing anterior hip joint stresses and improving the precision of hip motion through correction of alignment and movement impairments noted during functional activities and dance. Successful outcomes included a reduction in pain and return to professional ballet dancing. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Bone Remodeling in Acetabular Reconstruction Using a Kerboull-Type Reinforcement Device and Structural Bone-Grafting in Total Hip Arthroplasty.

    PubMed

    Oe, Kenichi; Iida, Hirokazu; Tsuda, Kohei; Nakamura, Tomohisa; Okamoto, Naofumi; Ueda, Yusuke

    2017-03-01

    The purpose of this study was to identify the long-term durability of the Kerboull-type reinforcement device (KT plate) in acetabular reconstruction for massive bone defects, assessing the remodeling of structural bone grafts. This study retrospectively evaluated 106 hips that underwent acetabular reconstruction using a KT plate between November 2000 and December 2010. Thirty-eight primary total hip arthoplasties (THAs) and 68 revised THAs were performed, and the mean duration of clinical follow-up was 8 years (5-14 years). Regarding reconstructing the acetabular bone defects, autografts were used in 37 hips, allografts in 68 hips, and A-W glass ceramics in 2 hips. One hip exhibited radiological migration and no revision for aseptic loosening. The mean Merle d'Aubigné Clinical Score improved from 7.5 points (4-12 points) preoperatively to 10.9 points (9-18 points) at the last follow-up. The Kaplan-Meier survival rate for radiological migration of primary and revised THAs at 10 years was 100% and 97% (95% confidence interval: 96%-100%), respectively. Bone remodeling was evaluated using the radiological demarcation at the bone-to-bone interface, and an improvement of 100% in primary THAs and 94% in revised THAs was observed. For massive bone defects, acetabular reconstruction using the KT plate with a structural bone grafting can yield successful results. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. The use of low-intensity pulsed ultrasound in treating delayed union of fifth metatarsal fractures.

    PubMed

    Teoh, Kar Hao; Whitham, Robert; Wong, Jenny F; Hariharan, Kartik

    2018-01-31

    There are no studies looking at the success rate of low-intensity pulsed ultrasound (LIPUS) in fifth metatarsal fracture delayed unions to our knowledge. The aim of this study is to investigate the use of LIPUS treatment for delayed union of fifth metatarsal fractures. A retrospective review of patients who were treated with LIPUS following a delayed union of fifth metatarsal fracture was conducted over a three-year period. There were thirty patients (9 males, 21 females) in this cohort. The average age was 39.3 years. Type 2 fractures made up 43% of our cohort. Twenty-seven (90%) patients went on to progress to union clinically and radiologically following LIPUS treatment. Smoking (p=0.014) was predictive of non-union. Assuming that there were 10 delayed unions a year and 6 went on to non-union as previously suggested by a systematic review, the cost savings of using LIPUS (90% success rate; 10 LIPUS machine and surgery for 1 non-union) vs operative intervention (surgery for 6 non-union) equates to a cost saving of £7765 a year. There is a role for the use of LIPUS in delayed union of fifth metatarsal fractures and can serve as an adjunct prior to consideration of surgery. The findings of this study also suggest the use of LIPUS to be a cost effective treatment modality compared to surgical management. Level 4. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Multifocal humeral fractures.

    PubMed

    Maresca, A; Pascarella, R; Bettuzzi, C; Amendola, L; Politano, R; Fantasia, R; Del Torto, M

    2014-02-01

    Multifocal humeral fractures are extremely rare. These may affect the neck and the shaft, the shaft alone, or the diaphysis and the distal humerus. There is no classification of these fractures in the literature. From 2004 to 2010, 717 patients with humeral fracture were treated surgically at our department. Thirty-five patients presented with an associated fracture of the proximal and diaphyseal humerus: synthesis was performed with plate and screws in 34 patients, and the remaining patient had an open fracture that was treated with an external fixator. Mean follow-up was 3 years and 3 months. A classification is proposed in which type A fractures are those affecting the proximal and the humeral shaft, type B the diaphysis alone, and type C the diaphysis in association with the distal humerus. Type A fractures are then divided into three subgroups: A-I, undisplaced fracture of the proximal humerus and displaced shaft fracture; A-II: displaced fracture of the proximal and humeral shaft; and A-III: multifragmentary fracture affecting the proximal humerus and extending to the diaphysis. Multifocal humeral fractures are very rare and little described in the literature, both for classification and treatment. The AO classification describes bifocal fracture of the humeral diaphysis, type B and C. The classification suggested in this article mainly concerns fractures involving the proximal and humeral shaft. A simple classification of multifocal fractures is suggested to help the surgeon choose the most suitable type of synthesis for surgical treatment. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint (hemi-hip) acetabular metal cemented prosthesis. 888.3370 Section 888.3370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint...

  17. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint (hemi-hip) acetabular metal cemented prosthesis. 888.3370 Section 888.3370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint...

  18. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint (hemi-hip) acetabular metal cemented prosthesis. 888.3370 Section 888.3370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint...

  19. Treating osteoporotic vertebral compression fractures with intraosseous vacuum phenomena using high-viscosity bone cement via bilateral percutaneous vertebroplasty

    PubMed Central

    Guo, Dan; Cai, Jun; Zhang, Shengfei; Zhang, Liang; Feng, Xinmin

    2017-01-01

    Abstract Osteoporotic vertebral compression fractures with intraosseous vacuum phenomena could cause persistent back pains in patients, even after receiving conservative treatment. The aim of this study was to evaluate the efficacy of using high-viscosity bone cement via bilateral percutaneous vertebroplasty in treating patients who have osteoporotic vertebral compression fractures with intraosseous vacuum phenomena. Twenty osteoporotic vertebral compression fracture patients with intraosseous vacuum phenomena, who received at least 2 months of conservative treatment, were further treated by injecting high-viscosity bone cement via bilateral percutaneous vertebroplasty due to failure of conservative treatment. Treatment efficacy was evaluated by determining the anterior vertebral compression rates, visual analog scale (VAS) scores, and Oswestry disability index (ODI) scores at 1 day before the operation, on the first day of postoperation, at 1-month postoperation, and at 1-year postoperation. Three of 20 patients had asymptomatic bone cement leakage when treated via percutaneous vertebroplasty; however, no serious complications related to these treatments were observed during the 1-year follow-up period. A statistically significant improvement on the anterior vertebral compression rates, VAS scores, and ODI scores were achieved after percutaneous vertebroplasty. However, differences in the anterior vertebral compression rate, VAS score, and ODI score in the different time points during the 1-year follow-up period was not statistically significant (P > 0.05). Within the limitations of this study, the injection of high-viscosity bone cement via bilateral percutaneous vertebroplasty for patients who have osteoporotic vertebral compression fractures with intraosseous vacuum phenomena significantly relieved their back pains and improved their daily life activities shortly after the operation, thereby improving their life quality. In this study, the use of high

  20. Acetabular labral tears with underlying chondromalacia: a possible association with high-level running.

    PubMed

    Guanche, Carlos A; Sikka, Robby S

    2005-05-01

    The use of hip arthroscopy has helped delineate intra-articular pathology and has enabled clinicians to further elucidate the factors responsible for injuries, such as running. The subtle development of degenerative changes may be a result of repetitive impact loading associated with this sport. This study presents a population of runners with common pathologic acetabular changes. Case series. Eight high-level runners with an average age of 36 years (range, 19 to 45 years) were seen for complaints of increasing hip pain with running without any history of macrotrauma. All of the patients had either run several marathons (4), were triathletes (1), Olympic middle distance runners (1), or had run more than 10 miles per week for longer than 5 years (2). Plain radiographic analysis revealed no degenerative changes and an average center-edge (CE) angle of 36.7 degrees (range, 28 degrees to 44 degrees). All patients underwent hip arthroscopy with labral debridement. In 6 patients (75%), a chondral injury of the acetabular cartilage underlying the labral tear was noted. In addition, 3 patients had ligamentum teres disruptions. It is possible that the development of these tears is the result of subtle instability, which may be exacerbated by running, eventually leading to labral tearing and possible ligamentum teres disruption. While perhaps concurrently, subtle acetabular dysplasia may play a role. Although this study does not confirm an association between running and the development of labral tears or chondral lesions in the hip, it certainly questions whether there is an injury pattern common to this population, a "runner's hip." Level IV.

  1. Hip Resurfacing Using Highly Cross-linked Polyethylene: Prospective Study Results at 8.5 Years.

    PubMed

    Pritchett, James W

    2016-10-01

    Hip resurfacing is an option to consider when treating younger, more active patients. Advantages over total hip arthroplasty include a more normal gait and a lower incidence of thigh pain. In this prospective study, 190 hip resurfacing procedures (164 participants) were performed using a cobalt-chromium femoral component and a cementless acetabular cup with a 3.8-mm highly cross-linked polyethylene acetabular liner. The mean follow-up was 8.5 (range, 7-10) years. Two participants were lost to follow-up and 2 died. One participant underwent successful revision surgery for acetabular loosening. Four participants underwent successful revision to a total hip arthroplasty because of femoral neck fracture (2), femoral loosening, or infection. The Kaplan-Meier survivorship was 97%. Acetabular bone conservation was assessed using computed tomography by measuring the medial acetabular wall. The mean thickness was 9 mm. Femoral bone was well preserved with a mean head:neck ratio of 1.37. There were 4 (2%) osteolytic defects up to 0.9 cm(3) on computed tomography and no instances of impending polyethylene wear-through. Seven polyethylene retrievals had a measured wear rate of 0.05 mm/y. Hip resurfacing using a highly cross-linked polyethylene acetabular component is a reliable procedure. Both femoral and acetabular bones are reasonably preserved compared with prior resurfacing methods. The low incidence of osteolysis and the low rate of wear found on retrievals suggest that many years of use in highly active patients is possible. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Pathological fractures in children

    PubMed Central

    De Mattos, C. B. R.; Binitie, O.; Dormans, J. P.

    2012-01-01

    Pathological fractures in children can occur as a result of a variety of conditions, ranging from metabolic diseases and infection to tumours. Fractures through benign and malignant bone tumours should be recognised and managed appropriately by the treating orthopaedic surgeon. The most common benign bone tumours that cause pathological fractures in children are unicameral bone cysts, aneurysmal bone cysts, non-ossifying fibromas and fibrous dysplasia. Although pathological fractures through a primary bone malignancy are rare, these should be recognised quickly in order to achieve better outcomes. A thorough history, physical examination and review of plain radiographs are crucial to determine the cause and guide treatment. In most benign cases the fracture will heal and the lesion can be addressed at the time of the fracture, or after the fracture is healed. A step-wise and multidisciplinary approach is necessary in caring for paediatric patients with malignancies. Pathological fractures do not have to be treated by amputation; these fractures can heal and limb salvage can be performed when indicated. PMID:23610658

  3. Infection rate in adult patients with open fractures treated at the emergency hospital and at the ULBRA university hospital in Canoas, Rio Grande do Sul, Brazil.

    PubMed

    Guerra, Marcelo Teodoro Ezequiel; Gregio, Fernando Machado; Bernardi, Adriane; Castro, Cyntia Cordeiro de

    2017-01-01

    To identify the infection rate in adult patients with open fractures treated at two tertiary hospitals in the city of Canoas, Rio Grande do Sul, Brazil. This quantitative descriptive study was conducted at Hospital de Pronto Socorro de Canoas. Eligible participants were adults aged 18-60 years with open fractures who were admitted to the orthopedic trauma service from January to May 2014 and followed-up for one year. A total of 133 patients with open fractures were included; most were men (92.48%), with a mean age of 36 years. There was a predominance of Gustilo-Anderson type III fractures. The infection rate was 18.80%, being more frequent in Gustilo-Anderson type III fractures (72.00%). The most commonly observed bacteria were Staphylococcus aureus and Enterobacter aerogenes . The infection rate in open fractures of patients initially treated at the emergency department of HPSC was 18.8%. The infections occurred predominantly in Gustilo-Anderson type III fractures. The bacteria with the highest incidence in infections were Staphylococcus aureus and Enterobacter aerogenes .

  4. Undisplaced Intraoperative Fracture Presenting as Early Dislocation with Tapered Wedge Stems in Total Hip Arthroplasty - Case Series and Review of Literature

    PubMed Central

    Reddy, A V Gurava; Eachempati, Krishna Kiran; Mugalur, Aakash; Suchinder, A; Rao, V B N Prasad; Kamurukuru, Nalanda

    2017-01-01

    Introduction: Periprosthetic fractures and dislocation in the early post-operative period can be disastrous both for the surgeon and the patient. However, undisplaced periprosthetic fractures presenting with dislocation is uncommon. We describe successful management of two cases (one bilateral dislocation and one unilateral dislocation) of undisplaced iatrogenic fractures in total hip arthroplasty (THA) presenting as early dislocation. Case Report: Case 1 was a 45-year-old female with osteoarthritis of hip secondary to developmental dysplasia of the hip with bilateral early nontraumatic dislocation with bilateral identical periprosthetic fracture. It was managed by revision to long stem and encirclage wiring. Case 2 presented with early dislocation in the 2nd week post THA. We found an intertrochanteric fracture intra-operatively with unstable implant. Acetabular component and femoral component revision were done with reconstruction of the greater trochanter. Discussion: These fractures could be occult iatrogenic fractures characteristic of taper wedge stems which presented as early nontraumatic dislocation in the post-operative period. The prosthesis subsidence, loss of muscle tension and change of version might be the factors leading to dislocation. Conclusion: Unrecognized incomplete intraoperative fracture can occur with tapered wedge uncemented stems which can present as a dislocation in the immediate post-operative period. This will require early revision of the femoral component. PMID:29051875

  5. Effect of fiber post length and abutment height on fracture resistance of endodontically treated premolars prepared for zirconia crowns.

    PubMed

    Lin, Jie; Matinlinna, Jukka Pekka; Shinya, Akikazu; Botelho, Michael George; Zheng, Zhiqiang

    2018-04-01

    The purpose of this study was to compare the fracture resistance, mode of fracture, and stress distribution of endodontically treated teeth prepared with three different fiber post lengths and two different abutment heights, using both experimental and finite element (FE) approaches. Forty-eight human maxillary premolars with two roots were selected and endodontically treated. The teeth were randomly distributed into six equally sized groups (n = 8) with different combinations of post lengths (7.5, 11, and 15 mm) and abutment heights (3 and 5 mm). All the teeth restored with glass fiber post (Rely X Fiber Post, 3M ESPE, USA) and a full zirconia crown. All the specimens were thermocycled and then loaded to failure at an oblique angle of 135°. Statistical analysis was performed for the effects of post length and abutment height on failure loads using ANOVA and Tukey's honestly significant difference test. In addition, corresponding FE models of a premolar restored with a glass fiber post were developed to examine mechanical responses. The factor of post length (P < 0.01) had a significant effect on failure load. The abutment height (P > 0.05) did not have a significant effect on failure load. The highest mean fracture resistance was recorded for the 15 mm post length and 5 mm abutment height test group, which was significantly more resistant to fracture than the 7.5 mm post and 5 mm abutment height group (P < 0.05). The FE analysis showed the peak compression and tension stress values of 7.5 mm post length were higher than that of 11 and 15 mm post length. The stress value of remaining tooth decreased as the post length was increased. Within the limitations of this experimental and FE analysis study, increasing the post length inside the root of endodontically treated premolar teeth restored with glass-fiber posts increase the fracture resistance to non-axial forces. Failure mode is more favorable with reduced abutment heights.

  6. Comparison of the diagnostic value of ultrasonography and standing radiography for pelvic-femoral disorders in horses.

    PubMed

    Geburek, Florian; Rötting, Anna K; Stadler, Peter M

    2009-04-01

    To assess agreement between ultrasonography (transcutaneous and transrectal) and standing radiography in horses with fractures in the pelvic region and disorders of the coxofemoral joint. Case series. Warmblood horses (n=23) and 2 ponies. Medical records (1999-2008) of equids with pelvic or coxofemoral disorders that had pelvic radiography and ultrasonography were retrieved and results of both techniques compared. Radiography and ultrasonography each identified equal numbers of fractures of the tuber coxa (n=4), ilial shaft (2), ischium (3), femoral neck (2), and osteoarthritis/osis of the coxofemoral joint (6). Fractures of the ilial wing (4) were only identified by ultrasonography not by standing radiography. Of 9 acetabular fractures, 3 were identified on radiographs only, 5 were identified with both modalities. One pubic fracture was identified using ultrasonography and radiography. One acetabular and 1 pubic fracture were only diagnosed on necropsy. We found reasonable agreement (73%; 24/33) between ultrasonography and standing radiography for diagnosis of pelvic-femoral disorders. Ultrasonography was more useful for ilial wing fractures and radiography for acetabular fractures. Ultrasonography is a rapid, safe imaging technique for detecting disorders of the pelvic region with a high diagnostic yield and is a preferred initial approach in horses with severe hindlimb lameness.

  7. Effect of screw fixation on acetabular component alignment change in total hip arthroplasty.

    PubMed

    Fujishiro, Takaaki; Hayashi, Shinya; Kanzaki, Noriyuki; Hashimoto, Shingo; Shibanuma, Nao; Kurosaka, Masahiro

    2014-06-01

    The use of screws can enhance immediate cup fixation, but the influence of screw insertion on cup position has not previously been measured. The purpose of this study was to quantitatively evaluate the effect of intra-operative screw fixation on acetabular component alignment that has been inserted with the use of a navigation system. We used a navigation system to measure cup alignment at the time of press-fit and after screw fixation in 144 hips undergoing total hip arthroplasty. We also compared those findings with factors measured from postoperative radiographs. The mean intra-operative change of cup position was 1.78° for inclination and 1.81° for anteversion. The intra-operative change of anteversion correlated with the number of screws. The intra-operative change of inclination also correlated with medial hip centre. The insertion of screws can induce changes in cup alignment, especially when multiple screws are used or if a more medial hip centre is required for rigid acetabular fixation.

  8. [Clinical experience with various techniques integrated treat the wounded with gunshot fractures of limbs].

    PubMed

    Kozlov, V K; Akhmedov, B G; Chililov, A M

    To increase an efficiency of complex treatment of patients with diaphyseal gunshot fractures of long bones by introduction of modern minimally invasive surgical techniques of internal osteosynthesis into clinical practice of civil health care and to improve the outcomes in victims. Prospective comparative clinical trial included 104 victims from the Republic of Yemen with gunshot wounds of limbs of various severity for the period 2009-2011. There were diaphyseal fractures of long bones of limbs associated with soft tissue injuries. Men were predominant (80.7%). Age ranged from 15 to 80 years (mean 38,5 ± 5,7 years). Various surgical techniques of simultaneous and staged treatment were used for gunshot fractures of long bones of limbs. Additional immune therapy was prescribed to prevent infectious complications in the most severe cases. Victims were comprehensively treated according to different staged treatment: conventional surgical treatment with external fixation devices or early primary minimally invasive functionally stable osteosynthesis with LCP/BIOS plates were applied for low-energy fractures; in case of high-energy fractures the first stage included external fixation devices deployment followed by their subsequent replacement during delayed minimally invasive osteosynthesis. The essence of improvement is pursuit to simultaneous minimally invasive surgery by using of current plates for osteosynthesis and preventive immunotherapy of immune dysfunction to eliminate infectious complications. As a result, we obtained 2-fold decrease of surgical invasiveness (r≤0,01) and hospital-stay (r≤0,01). Repeated osteosynthesis was not made. Also 4-fold and 40-fold reduction of infectious and noninfectious complications was observed. This management was accompanied by reduced rehabilitation tine and significantly improved quality of life. Improved technique and algorithm of complex treatment of diaphyseal gunshot fractures of long bones of limbs were described

  9. [Calcaneal fractures treated by open reduction and internal fixation with a locking compression plate (LCP). A prospective study. part I: basic analysis of the group].

    PubMed

    Svatoš, F; Bartoška, R; Skála-Rosenbaum, J; Douša, P; Pacovský, V; Krbec, M

    2011-01-01

    In a prospective study of patients with calcaneal fractures treated by open reduction from an extensile lateral approach and LCP osteosynthesis, the authors evaluated the basic epidemiological data, mechanism of injury, type of fracture, essential data on surgery, days of hospital stay and the number of complications. In the period from September 1, 2006 to July 31, 2010, a total of 230 patients with 243 calcaneal fractures were treated. The fractures were classified as either open or closed and according to the Essex-Lopresti system. Of the total number of patients, 135 (55.6 % of all fractures) were indicated for conservative treatment and 108 (44.4% of all fractures) for surgical intervention. Indications for surgery based on the generally accepted criteria enabled us to select 77 patients with 82 fractures (33.7 % of all fractures) for treatment by the method of open reduction and LCP osteosynthesis. These patients constituted the group evaluated here. The other patients were treated using other techniques (21 fractures, i.e., 8.6 % of all fractures, by the Stehlík-Štulík transfixation method and further five [2.1 %] by screw osteosynthesis). Six surgeons were involved in the treatment of this group. For the diagnosis of fractures, plain radiographs in lateral and axial projection and axial and coronal CT images were used. All fractures were treated after subsidence of oedema by the method of open reduction and LCP fixation from an extensile lateral approach, with the use of a tourniquet. The follow-up period for the evaluation of functional outcome and bone union was 3 to 48 months. Fifty patients were followed up for over one year. The group evaluated comprised 58 men (75.3 %) with 63 fractures (76.8 %) and 19 women (24.7 %) with 19 fractures (23.2 %). The average age of the group was 42 years, with 41 years (range, 22-61 years) in men and 47 years (range, 30-70 years) in women. The most frequent cause of injury was a fall from a height below 1 metre and

  10. A new approach for assessment of wear in metal-backed acetabular cups using computed tomography: a phantom study with retrievals.

    PubMed

    Jedenmalm, Anneli; Noz, Marilyn E; Olivecrona, Henrik; Olivecrona, Lotta; Stark, Andre

    2008-04-01

    Polyethylene wear is an important cause of aseptic loosening in hip arthroplasty. Detection of significant wear usually happens late on, since available diagnostic techniques are either not sensitive enough or too complicated and expensive for routine use. This study evaluates a new approach for measurement of linear wear of metal-backed acetabular cups using CT as the intended clinically feasible method. 8 retrieved uncemented metal-backed acetabular cups were scanned twice ex vivo using CT. The linear penetration depth of the femoral head into the cup was measured in the CT volumes using dedicated software. Landmark points were placed on the CT images of cup and head, and also on a reference plane in order to calculate the wear vector magnitude and angle to one of the axes. A coordinate-measuring machine was used to test the accuracy of the proposed CT method. For this purpose, the head diameters were also measured by both methods. Accuracy of the CT method for linear wear measurements was 0.6 mm and wear vector angle was 27 degrees . No systematic difference was found between CT scans. This study on explanted acetabular cups shows that CT is capable of reliable measurement of linear wear in acetabular cups at a clinically relevant level of accuracy. It was also possible to use the method for assessment of direction of wear.

  11. Corrosion on the acetabular liner taper from retrieved modular metal-on-metal total hip replacements.

    PubMed

    Gascoyne, Trevor C; Dyrkacz, Richard M; Turgeon, Thomas R; Burnell, Colin D; Wyss, Urs P; Brandt, Jan-M

    2014-10-01

    Eight retrieved metal-on-metal total hip replacements displayed corrosion damage along the cobalt-chromium alloy liner taper junction with the Ti alloy acetabular shell. Scanning electron microscopy indicated the primary mechanism of corrosion to be grain boundary and associated crevice corrosion, which was likely accelerated through mechanical micromotion and galvanic corrosion resulting from dissimilar alloys. Coordinate measurements revealed up to 4.3mm(3) of the cobalt-chromium alloy taper surface was removed due to corrosion, which is comparable to previous reports of corrosion damage on head-neck tapers. The acetabular liner-shell taper appears to be an additional source of metal corrosion products in modular total hip replacements. Patients with these prostheses should be closely monitored for signs of adverse reaction towards corrosion by-products. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Orbital fractures treated in Auckland from 2010-2015: review of patient outcomes.

    PubMed

    Anand, Lanit; Sealey, Christopher

    2017-07-07

    The purpose of this study was to review patient outcomes from surgical reconstruction of isolated orbital fractures, performed by the Auckland District Health Board (ADHB) Oral and Maxillofacial Surgery service (OMFS), from 2010 to 2015. In particular, we wished to assess titanium as an orbital reconstructive material and compare outcomes with the international literature. Hospital records for 103 adults (>18 years old) who underwent repair of isolated orbital fractures by the OMFS department at Middlemore Hospital, between 2010 and 2015, were reviewed. Information collected included patient characteristics, cause of injury, type of reconstruction material used and post-operative complications. Patients were then followed up by means of a verbal telephone questionnaire. The majority of patients were male in the 18-30 year age group, with interpersonal violence being the leading cause of injury. Titanium was the preferred choice of reconstructive material. Seven patients required return to theatre to resolve post-operative complications. Sixty-four patients could be contacted by telephone (12 months to six years follow-up). Thirty patients, who could not be contacted by telephone, did attend clinic follow-up and were assessed from their hospital records (minimum of one month follow-up). Ten patients could not be contacted by telephone and had not attended clinic follow-up. Problems with diplopia, paraesthesia and cosmesis were within complication rates reported in the literature. Patients with isolated orbital fractures, treated by the Oral and Maxillofacial Surgery Department in Auckland from 2010-2015, were reviewed. Titanium was the most commonly used reconstructive material and proved to be well tolerated. Complication rates were within international norms.

  13. Management of Symphysis and Parasymphysis Mandibular Fractures in Children Treated with MacLennan Splint: Stability and Early Results

    PubMed Central

    Bhat, Manohar; Sharma, Anupama; Sharma, Rajesh

    2015-01-01

    ABSTRACT Objective: The aim of this study was to assess the safety and efficiency of MacLennan splint in symphysis and parasymphysis mandibular fractures in children. Study design: Six patients (four boys and two girls, mean age 3 years, range between 2 and 5 years) were operated on parasymphysis fractures of children. The mean follow-up time was 12 months. MacLennan splint was applied in these case upto 3 weeks. Results: Primary healing of the fractured mandible was observed in all patients. Postoperative complications were minor and transient. The outcome of the operation was not endangered. Adverse tissue reaction like infection, malocclusion, swelling and growth restrictions did not occur during observation period. Conclusion: MacLennan splint is having various advantages like faster mobilization and the avoidance of secondary removal operations. Based on this preliminary results MacLennan splints are safe and efficient in the treatment of pediatric mandible fracture. How to cite this article: Khairwa A, Bhat M, Sharma A, Sharma R. Management of Symphysis and Parasymphysis Mandibular Fractures in Children Treated with MacLennan Splint: Stability and Early Results. Int J Clin Pediatr Dent 2015;8(2):127-132. PMID:26379381

  14. Occipital Neuralgia after Occipital Cervical Fusion to Treat an Unstable Jefferson Fracture

    PubMed Central

    Kong, Seong Ju; Park, Jin Hoon

    2012-01-01

    In this report we describe a patient with an unstable Jefferson fracture who was treated by occipitocervical fusion and later reported sustained postoperative occipital neuralgia. A 70-year-old male was admitted to our center with a Jefferson fracture induced by a car accident. Preoperative lateral X-ray revealed an atlanto-dens interval of 4.8mm and a C1 canal anterior-posterior diameter of 19.94mm. We performed fusion surgery from the occiput to C5 without decompression of C1. The patient reported sustained continuous pain throughout the following year despite strong analgesics. The pain dermatome was located mainly in the great occipital nerve territory and posterior neck. Magnetic resonance images revealed no evidence of cord compression, however a C1 lamina compressed dural sac and C2 root compression could not be excluded. We performed bilateral C2 root decompression via a C1 laminectomy. After decompression, bilateral C2 root redundancy was identified by palpation. After decompression surgery, pain was reduced. This case indicates that occipital neuralgia, suggesting the need for diagnostic block, should be considered in the differential diagnosis of patients with sustained occipital headache after occipitocervical fusion surgery. PMID:25983846

  15. Influence of remaining coronal tooth structure on fracture resistance and failure mode of restored endodontically treated maxillary incisors.

    PubMed

    Santos Pantaleón, Domingo; Morrow, Brian R; Cagna, David R; Pameijer, Cornelis H; Garcia-Godoy, Franklin

    2018-03-01

    Limited information is available on the effect of an incomplete ferrule because of the varying residual axial wall heights and the volume of residual tooth structure on the fracture resistance of endodontically treated and restored maxillary incisors. The purpose of this in vitro investigation was to examine the effect of varying residual axial wall heights, residual coronal tooth structure, and the absence of 1 proximal axial wall on the fracture resistance and failure mode of endodontically treated teeth restored with metal posts. Sixty intact human maxillary central incisors were divided into 6 groups (n=10): no ferrule (NF), 2-mm complete ferrule (CF2), 2-mm (IF2), 3-mm (IF3), and 4-mm (IF4) incomplete ferrules missing a single interproximal wall, and a control group that had a 6-mm incomplete ferrule (IF6). Cast metal post-and-cores were placed in all experimental specimens except for controls. Control specimens received 1 interproximal cavity preparation extending to the root canal access and a composite resin restoration. Complete metal crowns were then cemented on all specimens. Completed specimens were subjected to thermocycling (6000 cycles, 5°C/55°C) followed by the immediate testing of fracture resistance. Failed specimens were sectioned buccolingually and evaluated to identify the failure mode. The data were analyzed with an analysis of variance (ANOVA) and the Student-Newman-Keuls multiple comparison test (α=.05). An incomplete ferrule (IF2) with 1 interproximal wall missing had significantly reduced fracture resistance (697 N) compared with a complete ferrule (932 N). An increase of 3 to 4 mm of remaining wall height improved fracture resistance, from 844 N (IF3) to 853 N (IF4). Partial decementation was noticed in 8 NF and 5 IF2 specimens. IF3 and IF4 had no decementations. Radicular fractures and cracks (catastrophic failure) were observed in all IF2, IF3, and IF4, 9 CF2, and 6 NF specimens. In 7 specimens without posts (IF6, control

  16. Influence of natural fractures on hydraulic fracture propagation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teufel, L.W.; Warpinski, N.R.

    Hydraulic fracturing has become a valuable technique for the stimulation of oil, gas, and geothermal reservoirs in a variety of reservoir rocks. In many applications, only short fractures are needed for economic production. In low-permeability reservoirs, however, long penetrating fractures are generally needed, and in this case, natural fractures can be the cause of many adverse effects during a fracture treatment. Natural fractures can influence the overall geometry and effectiveness of the hydraulic fracture by: (1) arresting the vertical or lateral growth, (2) reducing total fracture length via fluid leakoff, (3) limiting proppant transport and placement, and (4) enhancing themore » creation of multiple or secondary fractures rather than a single planar hydraulic fracture. The result may range from negligible to catastrophic depending on the values of the ancillary treatment and reservoir parameters, such as the treating pressure, in-situ stresses, pore pressure, orientations of the natural fractures relative to principal in-situ stresses, spacing and distribution of the natural fractures, permeability, etc. Field observations from mineback experiments at DOE's Nevada Test Site and the multiwell experiment in Colorado, laboratory tests, and analyses of these data are integrated to describe the complex fracture behavior found and to provide guidelines for predicting when this complex fracturing will occur.« less

  17. Influence of natural fractures on hydraulic fracture propagation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teufel, L.W.; Warpinski, N.R.

    Hydraulic fracturing has become a valuable technique for the stimulation of oil, gas, and geothermal reservoirs in a variety of reservoir rocks. In many applications, only short fractures are needed for economic production. In low-permeability reservoirs, however, long penetrating fractures are generally needed, and in this case, natural fractures can be the cause of many adverse effects during a fracture treatment. Natural fractures can influence the overall geometry and effectiveness of the hydraulic fracture by: (1) arresting the vertical or lateral growth, (2) reducing total fracture length via fluid leakoff, (3) limiting proppant transport and placement, and (4) enhancing themore » creation of multiple or secondary fractures rather than a single planar hydraulic fracture. The result may range from negligible to catastrophic depending on the values of the ancillary treatment and reservoir parameters, such as the treating pressure, in-situ stresses, pore pressure, orientations of the natural fractures relative to principle in-situ stresses, spacing and distribution of the natural fractures, permeability, etc. Field observations from mineback experiments at DOE's Nevada Test Site and the multiwell experiment in Colorado, laboratory tests, and analyses of these data are integrated to describe the complex fracture behavior found to an provide guidelines for predicting when this complex fracturing occurs.« less

  18. Perioperative mortality in hip fracture patients treated with cemented and uncemented hemiprosthesis: a register study of 11,210 patients.

    PubMed

    Talsnes, Ove; Vinje, Tarjei; Gjertsen, Jan Erik; Dahl, Ola E; Engesæter, Lars B; Baste, Valborg; Pripp, Are Hugo; Reikerås, Olav

    2013-06-01

    Adverse events associated with the use of bone cement for fixation of prostheses is a known complication. Due to inconclusive results in studies of hip fracture patients treated with cemented and uncemented hemiprostheses, this study was initiated. Our study is based on data reported to the Norwegian Hip Fracture Register on 11,210 cervical hip fractures treated with hemiprostheses (8,674 cemented and 2,536 uncemented). Significantly increased mortality within the first day of surgery was found in the cemented group (relative risk 2.9, 95 % confidence interval 1.6-5.1, p=0.001). The finding was robust giving the same results after adjusting for independent risk factors such as age, sex, cognitive impairment and comorbidity [American Society of Anesthesiologists (ASA) score]. For the first post-operative day the number needed to harm was 116 (one death for every 116 cemented prosthesis). However, in the most comorbid group (ASA worse than 3), the number needed to harm was only 33. We found increased mortality for the cemented hemiprosthesis the first post-operative day compared to uncemented procedures. This increased risk is closely related to patient comorbidity estimated by the patient's ASA score.

  19. Basic principles of fracture treatment in children.

    PubMed

    Ömeroğlu, Hakan

    2018-04-01

    This review aims to summarize the basic treatment principles of fractures according to their types and general management principles of special conditions including physeal fractures, multiple fractures, open fractures, and pathologic fractures in children. Definition of the fracture is needed for better understanding the injury mechanism, planning a proper treatment strategy, and estimating the prognosis. As the healing process is less complicated, remodeling capacity is higher and non-union is rare, the fractures in children are commonly treated by non-surgical methods. Surgical treatment is preferred in children with multiple injuries, in open fractures, in some pathologic fractures, in fractures with coexisting vascular injuries, in fractures which have a history of failed initial conservative treatment and in fractures in which the conservative treatment has no/little value such as femur neck fractures, some physeal fractures, displaced extension and flexion type humerus supracondylar fractures, displaced humerus lateral condyle fractures, femur, tibia and forearm shaft fractures in older children and adolescents and unstable pelvis and acetabulum fractures. Most of the fractures in children can successfully be treated by non-surgical methods.

  20. Does the optimal position of the acetabular fragment should be within the radiological normal range for all developmental dysplasia of the hip? A patient-specific finite element analysis.

    PubMed

    Wang, Xuyi; Peng, Jianping; Li, De; Zhang, Linlin; Wang, Hui; Jiang, Leisheng; Chen, Xiaodong

    2016-10-04

    The success of Bernese periacetabular osteotomy depends significantly on how extent the acetabular fragment can be corrected to its optimal position. This study was undertaken to investigate whether correcting the acetabular fragment into the so-called radiological "normal" range is the best choice for all developmental dysplasia of the hip with different severities of dysplasia from the biomechanical view? If not, is there any correlation between the biomechanically optimal position of the acetabular fragment and the severity of dysplasia? Four finite element models with different severities of dysplasia were developed. The virtual periacetabular osteotomy was performed with the acetabular fragment rotated anterolaterally to incremental center-edge angles; then, the contact area and pressure and von Mises stress in the cartilage were calculated at different correction angles. The optimal position of the acetabular fragment for patients 1, 2, and 3 was when the acetabular fragment rotated 17° laterally (with the lateral center-edge angle of 36° and anterior center-edge angle of 58°; both were slightly larger than the "normal" range), 25° laterally following further 5° anterior rotation (with the lateral center-edge angle of 31° and anterior center-edge angle of 51°; both were within the "normal" range), and 30° laterally following further 10° anterior rotation (with the lateral center-edge angle of 25° and anterior center-edge angle of 40°; both were less than the "normal" range), respectively. The optimal corrective position of the acetabular fragment is severity dependent rather than within the radiological "normal" range for developmental dysplasia of the hip. We prudently proposed that the optimal correction center-edge angle of mild, moderate, and severe developmental dysplasia of the hip is slightly larger than the "normal" range, within the "normal" range, and less than the lower limit of the "normal" range, respectively.

  1. Mechanobiological simulations of peri-acetabular bone ingrowth: a comparative analysis of cell-phenotype specific and phenomenological algorithms.

    PubMed

    Mukherjee, Kaushik; Gupta, Sanjay

    2017-03-01

    Several mechanobiology algorithms have been employed to simulate bone ingrowth around porous coated implants. However, there is a scarcity of quantitative comparison between the efficacies of commonly used mechanoregulatory algorithms. The objectives of this study are: (1) to predict peri-acetabular bone ingrowth using cell-phenotype specific algorithm and to compare these predictions with those obtained using phenomenological algorithm and (2) to investigate the influences of cellular parameters on bone ingrowth. The variation in host bone material property and interfacial micromotion of the implanted pelvis were mapped onto the microscale model of implant-bone interface. An overall variation of 17-88 % in peri-acetabular bone ingrowth was observed. Despite differences in predicted tissue differentiation patterns during the initial period, both the algorithms predicted similar spatial distribution of neo-tissue layer, after attainment of equilibrium. Results indicated that phenomenological algorithm, being computationally faster than the cell-phenotype specific algorithm, might be used to predict peri-prosthetic bone ingrowth. The cell-phenotype specific algorithm, however, was found to be useful in numerically investigating the influence of alterations in cellular activities on bone ingrowth, owing to biologically related factors. Amongst the host of cellular activities, matrix production rate of bone tissue was found to have predominant influence on peri-acetabular bone ingrowth.

  2. [Iliac spine fractures in children].

    PubMed

    Sułko, Jerzy; Olipra, Wojciech

    2010-01-01

    Iliac spine fractures in children are a form of avulsion fractures at mechanically weak spot caused by the presence of the growth plate. Presentation of observations concerning treatment and results of iliac spine fractures in children. 49 children (1 girl and 48 boys). Age, at the time of injury, average 15.1 years (10.6-18 years). We analyzed medical and radiological documentation of patients. 17 patients sustained anterior superior iliac spine fractures (ASIS), 32 fracture of the inferior iliac spine (AIIS). Most of injuries happened during sport activities--27 patients suffered fracture while playing football. 37 patients asked for medical advice immediately after the injury. Rest of patients, who came late--sustained AIIS fracture. We hospitalized 26 patients (53%), all of them suffered significant pain. The average length of stay in hospital was 8 days. All patients were treated conservatively. All of the fractures healed without complications. Larger study than ours group, concerning 84 patients with iliac spine fractures, was presented only by Italian authors who analyzed injures of professional athletes. In literature reviewed conservative treatment strongly predominates. Only a small group of patients were treated surgically (including athletes treated by Croatian surgeons). The treatment of iliac spines in children should be conservative, consisting of a couple days of bed rest and then for 2-3 weeks walking on crutches with only toe touching until the pain resolves. We recommend return to full activities after 2 months.

  3. [EFFECTIVENESS COMPARISON OF PROXIMAL FEMORAL NAIL ANTI-ROTATION IN SUPINE "SCISSORS" POSITION AND IN LITHOTOMY POSITION TO TREAT FEMORAL INTERTROCHANTERIC FRACTURES OF OLD PATIENTS].

    PubMed

    Du, Shihao; Yin, Fei; Wei, Xuming; Song, Sheng; Gu, Sanjun; Sun, Zhenzhong; Rui, Yongjun

    2016-02-01

    To compare the effectiveness of proximal femoral nail anti-rotation (PFNA) between in the supine "scissors" position and in the lithotomy position for treating femoral intertrochanteric fractures of old patients. A retrospective study was performed on 58 patients with femoral intertrochanteric fractures treated with PFNA between January 2013 and January 2015. Fracture was treated with PFNA in the lithotomy position in 28 cases (group A) and in the supine "scissors" position in 30 cases (group B). There was no significant difference in gender, age, side, cause of injury, fracture type, and interval from injury to operation between 2 groups (P>0.05). The incision length, operation time, perspective times, intraoperative blood loss, complications, and fracture healing time were recorded; Harris hip score was used to access the effectiveness. The wound healed by first intention without infection, pressure sores, deep vein thrombosis of lower extremity, and other complications. There was no significant difference in incision length between 2 groups (t=1.313, P=0.212). Group B was significantly better than group A in operation time, perspective times, and intraoperative blood loss (P<0.05). All patients were followed up 10-31 months (mean, 15.3 months). Stretch injury at normal side and perineal discomfort occurred in 1 case and 5 cases of group A respectively, and no nonunion and other complications was observed in the other patients. There was no significant difference in fracture healing time and Harris hip score at last follow-up between 2 groups (P>0.05). PFNA in the supine "scissors" position has exact effectiveness and advantages of shorter operation time, less intraoperative blood loss, less perspective times, and fewer complications.

  4. Direct medical costs attributable to peripheral fractures in Canadian post-menopausal women.

    PubMed

    Bessette, L; Jean, S; Lapointe-Garant, M-P; Belzile, E L; Davison, K S; Ste-Marie, L G; Brown, J P

    2012-06-01

    This study determined the cost of treating fractures at osteoporotic sites (except spine fractures) for the year following fracture. While the average cost of treating a hip fracture was the highest of all fractures ($46,664 CAD per fracture), treating other fractures also accounted for significant expenditures ($5,253 to $10,410 CAD per fracture). This study aims to determine the mean direct medical cost of treating fractures at peripheral osteoporotic sites in the year post-fracture (through 2 years post-hip fracture). Health administrative databases from the province of Quebec, Canada were used to estimate the cost of treating peripheral fractures at osteoporotic sites for the year following fracture (through 2 years for hip fractures). Included in costs analyses were physician claims, emergency and outpatient clinic costs, hospitalization costs, and subsequent costs for treatment of complications. A total of 15,827 patients (mean age 72 years) who suffered one fracture at an osteoporotic site had data for analyses. Hip/femur fractures had the highest rate of hospital stays related to fracture (91%) and the highest rate of hospital stays associated with a post-fracture complication (8%). In the year following fracture, the mean (SD) costs (2009 Canadian dollars) of treating acute fractures and post-fracture complications were: hip/femur fracture $46,664 ($43,198), wrist fracture $5,253 ($18,982), and fractures at other peripheral sites $10,410 ($27,641). The average (SD) cost of treating post-fracture complications at the hip/femur in the second year post-fracture was $1,698 ($12,462). Hospitalizations associated with the fracture accounted for 88% of the total cost of fracture treatment. The treatment of hip fractures accounts for a significant proportion of the costs associated with the treatment of peripheral osteoporotic fractures. Interventions to reduce the incidence of fractures, particularly hip fractures, would result in significant cost savings to the

  5. How Reliable is the Acetabular Cup Position Assessment from Routine Radiographs?

    PubMed Central

    Carvajal Alba, Jaime A.; Vincent, Heather K.; Sodhi, Jagdeep S.; Latta, Loren L.; Parvataneni, Hari K.

    2017-01-01

    Abstract Background: Cup position is crucial for optimal outcomes in total hip arthroplasty. Radiographic assessment of component position is routinely performed in the early postoperative period. Aims: The aims of this study were to determine in a controlled environment if routine radiographic methods accurately and reliably assess the acetabular cup position and to assess if there is a statistical difference related to the rater’s level of training. Methods: A pelvic model was mounted in a spatial frame. An acetabular cup was fixed in different degrees of version and inclination. Standardized radiographs were obtained. Ten observers including five fellowship-trained orthopaedic surgeons and five orthopaedic residents performed a blind assessment of cup position. Inclination was assessed from anteroposterior radiographs of the pelvis and version from cross-table lateral radiographs of the hip. Results: The radiographic methods used showed to be imprecise specially when the cup was positioned at the extremes of version and inclination. An excellent inter-observer reliability (Intra-class coefficient > 0,9) was evidenced. There were no differences related to the level of training of the raters. Conclusions: These widely used radiographic methods should be interpreted cautiously and computed tomography should be utilized in cases when further intervention is contemplated. PMID:28852355

  6. [Charnley-type total hip prosthesis. Radiological technic of angular measurements of the acetabular piece (anteversion)].

    PubMed

    Chevrot, A; Najman, G

    1983-01-01

    A radiological technique is described based on the study of antero-posterior and lateral views of the hip. Mathematical calculations by trigonometry make it possible to deduce the degree of anteversion of the acetabular cup. The necessary tables are given.

  7. [Complications of percutaneous kyphoplasty non-related with bone leakage in treating osteoporotic thoracolumbar vertebral compression fractures].

    PubMed

    Ru, Xuan-liong; Jiang, Zeng-hui; Gui, Xian-ge; Sun, Qi-cai; Song, Bo-Shan; Lin, Hang; He, Jian

    2015-08-01

    To analyze the complications of percutaneous kyphoplasty except bone leakge for the treatment of osteoporotic thoracolumbar vertebral compression fractures. From October 2008 to October 2012,178 patients with 224 osteoporotic vertebral compression fractures were treated with percutaneous kyphoplasty under local anethsia. There were 72 males and 106 females,ranging in age from 58 to 92 years old,with an average of 75.3 years,including 93 thoracic vertebrae and 131 lumbar vertebrae. The complications except bone cement leakage were analyzed during operation and after operation. All operations were successful and all patients were followed up from 12 to 60 months with an average of 26.2 months. No death was found. Bone cement leakage occurred in 27 cases, about 15.1% in 178 cases; and complications except bone cement leakage occurred in 15 cases. There was 1 case with cardiac arrest,was completely recovery by cardiopulmonary resuscitation (CPR) immediately; and 1 case with temporary absence of breathing,was recovery after treatment. There were 3 cases with fall of blood pressure and slower of heart rate; 1 case with intestinal obstruction; 2 cases with local hematoma and 1 case with intercostal neuralgia. Vertebral body fractures of 2 cases were split by bone cement and the fractures of adjacent body occurred in 4 cases. It's uncommon complication except bone cement leakge in treatment of osteoporotic thoracolumbar vertebral compression fractures with percutaneous kyphoplasty. The complication of cardiopulmonary system is a high risk in surgery; and cytotoxicity of bone cement,nervous reflex,fat embolism and alteration of intravertebral pressure may be main reasons.

  8. In vitro study of root fracture treated by CO2 laser and DP-bioactive glass paste.

    PubMed

    Wang, Yin-Lin; Lee, Bor-Shiunn; Tseng, Ching-Li; Lin, Feng-Huei; Lin, Chun-Pin

    2008-01-01

    An ideal material has yet to be discovered that can successfully treat vertical root fracture. Therefore, the purpose of this study was to use a continuous-wave CO2 laser of medium-energy density to fuse DP-bioactive glass paste (DPGP) to vertical root fracture. The DP-bioglass powder was based on a Na2O-CaO-SiO2-P2O5 system and it was mixed with phosphoric acid (65% concentration) with a powder/liquid ratio of 2 g/4 mL to form DPGP. The interaction of DPGP and dentin was analyzed by means of X-ray diffractometer (XRD) and differential thermal analysis/thermogravimetric analysis (DTA/TGA). Root fracture line was filled with DPGP followed by CO2 laser irradiation and the result was examined by scanning electron microscopy (SEM). The main crystal phase of DPGP was monocalcium phosphate monohydrate (Ca(H2PO4)2.H2O) and the phase transformed to dicalcium phosphate dihydrate (CaHPO4.2H2O) after mixing DPGP with dentin powder (DPG-D). Additionally, gamma-Ca2P2O7 and beta-Ca2P2O7 were identified when DPG-D was lased by CO2 laser. The reaction temperature was between 500 degrees C and 1100 degrees C. SEM results demonstrated that the fracture line was effectively sealed by DPGP. The chemical reaction of DPGP and dentin indicated that DPGP combined with CO2 laser is a potential regimen for the treatment of vertical root fracture.

  9. Functional outcome of Schatzker type V and VI tibial plateau fractures treated with dual plates

    PubMed Central

    Prasad, G Thiruvengita; Kumar, T Suresh; Kumar, R Krishna; Murthy, Ganapathy K; Sundaram, Nandkumar

    2013-01-01

    Background: Dual plate fixation in comminuted bicondylar tibial plateau fractures remains controversial. Open reduction and internal fixation, specifically through compromised soft tissues, has historically been associated with major wound complications. Alternate methods of treatment have been described, each with its own merits and demerits. We performed a retrospective study to evaluate the functional outcome of lateral and medial plate fixation of Schatzker type V and VI fractures through an anterolateral approach, and a medial minimally invasive approach or a posteromedial approach. Materials and Methods: We treated 46 tibial plateau fractures Schatzker type V and VI with lateral and medial plates through an anterolateral approach and a medial minimal invasive approach over an 8 years period. Six patients were lost to followup. Radiographs in two planes were taken in all cases. Immediate postoperative radiographs were assessed for quality of reduction and fixation. The functional outcome was evaluated according to the Oxford Knee Score criteria on followup. Results: Forty patients (33 men and 7 women) who completed the followup were included in the study. There were 20 Schatzker type V fractures and 20 Schatzker type VI fractures. The mean duration of followup was 4 years (range 1-8 years). All patients had a satisfactory articular reduction defined as ≤2 mm step-off or gap as assessed on followup. All patients had a good coronal and sagittal plane alignment, and articular width as assessed on supine X-rays of the knee in the anteroposterior (AP) and lateral views. The functional outcome, as assessed by the Oxford Knee Score, was excellent in 30 patients and good in 10 patients. All patients returned to their pre-injury level of activity and employment. There were no instances of deep infection. Conclusions: Dual plate fixation of severe bicondylar tibial plateau fractures is an excellent treatment option as it provides rigid fixation and allows early knee

  10. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... component is intended to be fixed with bone cement. The acetabular component is intended for use without bone cement (§ 888.3027). (b) Classification. Class III. (c) Date PMA or notice of completion of a PDP...

  11. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... component is intended to be fixed with bone cement. The acetabular component is intended for use without bone cement (§ 888.3027). (b) Classification. Class III. (c) Date PMA or notice of completion of a PDP...

  12. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... component is intended to be fixed with bone cement. The acetabular component is intended for use without bone cement (§ 888.3027). (b) Classification. Class III. (c) Date PMA or notice of completion of a PDP...

  13. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... component is intended to be fixed with bone cement. The acetabular component is intended for use without bone cement (§ 888.3027). (b) Classification. Class III. (c) Date PMA or notice of completion of a PDP...

  14. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... component is intended to be fixed with bone cement. The acetabular component is intended for use without bone cement (§ 888.3027). (b) Classification. Class III. (c) Date PMA or notice of completion of a PDP...

  15. Ten-year incidence and risk factors of bone fractures in a cohort of treated HIV1-infected adults

    PubMed Central

    Collin, Fidéline; Duval, Xavier; Lemoing, Vincent; Piroth, Lionel; Al Kaied, Firas; Massip, Patrice; Villes, Virginie; Chêne, Geneviève; Raffi, François

    2009-01-01

    In the ANRS CO8 APROCO-COPILOTE cohort of patients treated with combination antiretroviral therapy since 1997–1999, the incidence density of bone fractures was 3.3 for 1,000 patient-years (95% CI: 2.0–4.6). Rate was 2.9-fold (95% CI: 1.3–6.5) higher among patients with excessive alcohol consumption and 3.6-fold (95% CI: 1.6–8.1) higher in those with Hepatitis C virus (HCV) co-infection. Specific monitoring of HCV/HIV-coinfected patients and active promotion of alcohol cessation should be recommended for the prevention of bone fractures. PMID:19300202

  16. Finite element analysis of locking plate and two types of intramedullary nails for treating mid-shaft clavicle fractures.

    PubMed

    Ni, Ming; Niu, Wenxin; Wong, Duo Wai-Chi; Zeng, Wei; Mei, Jiong; Zhang, Ming

    2016-08-01

    Both plate and intramedullary nail fixations, including straight and anatomic nails, have been clinically adopted for the treatment of displaced mid-shaft clavicle fractures. However, the biomechanical performances of these fixations and implants have not been well evaluated. This study aims to compare the construct stability, stress distribution and fracture micro-motion of three fixations based on finite element (FE) method. The FE model of clavicle was reconstructed from CT images of a male volunteer. A mid-shaft fracture gap was created in the intact clavicle. Three fixation styles were simulated including locking plate (LP), anatomic intramedullary nail (CRx), and straight intramedullary nail (RCP). Two loading scenarios (axial compression and inferior bending) were applied at the distal end of the clavicle to simulate arm abduction, while the sternal end was fixed. Under both conditions, the LP was the stiffest, followed by the CRx, and the RCP was the weakest. LP also displayed a more evenly stress distribution for both implant and bone. RCP had a higher stress compared with CRx in both conditions. Moreover, all implants sustained higher stress level under the loading condition of bending than compression. The plate fixation significantly stabilizes the fracture gap, reduces the implant stress, and serves as the recommended fixation for the mid-shaft clavicle fracture. The CRx is an alternative device to treat clavicle shaft fracture, but the shoulder excessive activities should be avoided after operation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Vertical root fractures and their management

    PubMed Central

    Khasnis, Sandhya Anand; Kidiyoor, Krishnamurthy Haridas; Patil, Anand Basavaraj; Kenganal, Smita Basavaraj

    2014-01-01

    Vertical root fractures associated with endodontically treated teeth and less commonly in vital teeth represent one of the most difficult clinical problems to diagnose and treat. In as much as there are no specific symptoms, diagnosis can be difficult. Clinical detection of this condition by endodontists is becoming more frequent, where as it is rather underestimated by the general practitioners. Since, vertical root fractures almost exclusively involve endodontically treated teeth; it often becomes difficult to differentiate a tooth with this condition from an endodontically failed one or one with concomitant periodontal involvement. Also, a tooth diagnosed for vertical root fracture is usually extracted, though attempts to reunite fractured root have been done in various studies with varying success rates. Early detection of a fractured root and extraction of the tooth maintain the integrity of alveolar bone for placement of an implant. Cone beam computed tomography has been shown to be very accurate in this regard. This article focuses on the diagnostic and treatment strategies, and discusses about predisposing factors which can be useful in the prevention of vertical root fractures. PMID:24778502

  18. Diagnosis and Management of Common Foot Fractures.

    PubMed

    Bica, David; Sprouse, Ryan A; Armen, Joseph

    2016-02-01

    Foot fractures are among the most common foot injuries evaluated by primary care physicians. They most often involve the metatarsals and toes. Patients typically present with varying signs and symptoms, the most common being pain and trouble with ambulation. Diagnosis requires radiographic evaluation, although emerging evidence demonstrates that ultrasonography may be just as accurate. Management is determined by the location of the fracture and its effect on balance and weight bearing. Metatarsal shaft fractures are initially treated with a posterior splint and avoidance of weight-bearing activities; subsequent treatment consists of a short leg walking cast or boot for four to six weeks. Proximal fifth metatarsal fractures have different treatments depending on the location of the fracture. A fifth metatarsal tuberosity avulsion fracture can be treated acutely with a compressive dressing, then the patient can be transitioned to a short leg walking boot for two weeks, with progressive mobility as tolerated after initial immobilization. A Jones fracture has a higher risk of nonunion and requires at least six to eight weeks in a short leg non-weight-bearing cast; healing time can be as long as 10 to 12 weeks. Great toe fractures are treated with a short leg walking boot or cast with toe plate for two to three weeks, then a rigid-sole shoe for an additional three to four weeks. Lesser toe fractures can be treated with buddy taping and a rigid-sole shoe for four to six weeks.

  19. [Acetabular anteversion angle of the hip in the Mexican adult population measured with computed tomography].

    PubMed

    Rubalcava, J; Gómez-García, F; Ríos-Reina, J L

    2012-01-01

    Knowledge of the radiogrametric characteristics of a specific skeletal segment in a healthy population is of the utmost clinical importance. The main justification for this study is that there is no published description of the radiogrametric parameter of acetabular anteversion in a healthy Mexican adult population. A prospective, descriptive and cross-sectional study was conducted. Individuals of both genders older than 18 years and orthopedically healthy were included. They underwent a two-dimensional axial tomographic study of both hips to measure the acetabular anteversion angles. The statistical analysis consisted of obtaining central trend and scatter measurements. A multivariate analysis of variance (ANOVA) and statistical significance were performed. 118 individuals were studied, 60 males and 58 females, with a mean age of 47.7 +/- 16.7, and a range of 18-85 years. The anteversion of the entire group was 18.6 degrees + 4.1 degrees. Anteversion in males was 17.3 degrees +/- 3.5 degrees (10 degrees - 25 degrees) and in females 19.8 degrees +/- 4.7 degrees (10 degrees - 31 degrees). There were no statistically significant differences (p < or = 0.05) in right and left anteversion in the entire group. However, there were statistically significant differences (p > or = 0.005) both in the right and left sides when males and females were compared. Our study showed that there are great variations in the anteversion ranges of a healthy population. When our results are compared with those published by other authors the mean of most measurements exceeds 15 degrees. This should be useful to make therapeutic decisions that involve acetabular anteversion.

  20. Effect of a crown ferrule on the fracture strength of endodontically treated canines restored with fiber posts and metal-ceramic or all-ceramic crowns.

    PubMed

    Evangelinaki, Evangelia; Tortopidis, Dimitrios; Kontonasaki, Eleana; Fragou, Theodora; Gogos, Christos; Koidis, Petros

    2013-01-01

    The aim of this study was to comparatively evaluate the fracture strength of endodontically treated canines restored with glass-fiber posts (GFPs) and either metal-ceramic (MC) or all-ceramic (AC) crowns in the presence or absence of 2 mm of ferrule height. Fifty human maxillary canines were endodontically treated and randomly divided into five groups of 10 specimens each. The first group remained intact (control), while the remainder were restored with GFPs and composite cores with either MC or AC crowns. Each of the AC and MC groups was equally divided between teeth with or without ferrule. Teeth were embedded in acrylic resin and loaded at a 135-degree angle to their long axis until fracture. Fracture strength was not significantly different between ferrule and no ferrule groups (P = .571), but was significantly larger for the MC groups compared with the control and AC groups (P = .009 and P = .024, respectively). A significant effect of the type of restoration was found as teeth restored with MC crowns presented significantly higher fracture strength, independently of ferrule.

  1. Discrete Fracture Network Characterization of Fractured Shale Reservoirs with Implications to Hydraulic Fracturing Optimization

    NASA Astrophysics Data System (ADS)

    Jin, G.

    2016-12-01

    Shales are important petroleum source rocks and reservoir seals. Recent developments in hydraulic fracturing technology have facilitated high gas production rates from shale and have had a strong impact on the U.S. gas supply and markets. Modeling of effective permeability for fractured shale reservoirs has been challenging because the presence of a fracture network significantly alters the reservoir hydrologic properties. Due to the frequent occurrence of fracture networks, it is of vital importance to characterize fracture networks and to investigate how these networks can be used to optimize the hydraulic fracturing. We have conducted basic research on 3-D fracture permeability characterization and compartmentization analyses for fractured shale formations, which takes the advantages of the discrete fracture networks (DFN). The DFN modeling is a stochastic modeling approach using the probabilistic density functions of fractures. Three common scenarios of DFN models have been studied for fracture permeability mapping using our previously proposed techniques. In DFN models with moderately to highly concentrated fractures, there exists a representative element volume (REV) for fracture permeability characterization, which indicates that the fractured reservoirs can be treated as anisotropic homogeneous media. Hydraulic fracturing will be most effective if the orientation of the hydraulic fracture is perpendicular to the mean direction of the fractures. A DFN model with randomized fracture orientations, on the other hand, lacks an REV for fracture characterization. Therefore, a fracture permeability tensor has to be computed from each element. Modeling of fracture interconnectivity indicates that there exists no preferred direction for hydraulic fracturing to be most effective oweing to the interconnected pathways of the fracture network. 3-D fracture permeability mapping has been applied to the Devonian Chattanooga Shale in Alabama and the results suggest that an

  2. Fracture resistance of endodontically treated teeth restored with short fiber composite used as a core material-An in vitro study.

    PubMed

    Garlapati, Tejesh Gupta; Krithikadatta, Jogikalmat; Natanasabapathy, Velmurugan

    2017-10-01

    This in-vitro study tested the fracture resistance of endodontically treated molars with Mesial-Occluso-Distal (MOD) cavities restored with fibre reinforced composite material everX posterior in comparision with hybrid composite and ribbond fiber composite. Fifty intact freshly extracted human mandibular first molars were collected and were randomly divided into five groups (n=10). Group 1: positive control (PC) intact teeth without any endodontic preparation. In groups 2 through 6 after endodontic procedure standard MOD cavities were prepared and restored with their respective core materials as follows: group 2, negative control (NC) left unrestored or temporary flling was applied. Group 3, Hybrid composite (HC) as a core material (Te-Econom Plus Ivoclar Vivadent Asia) group 4, Ribbond (Ribbond; Seattle, WA, USA)+conventional composite resin (RCR) group 5, everX posterior (everX Posterior GC EUROPE)+conventional composite resin (EXP) after thermocycling fracture resistance for the samples were tested using universal testing machine. The results were analysed using ANOVA and Tukey's HSD post hoc tests. Mean fracture resistance (in Newton, N) was group 1: 1568.4±221.71N, group 2: 891.0±50.107N, group 3: 1418.3±168.71N, group 4:1716.7±199.51N and group 5: 1994.8±254.195N. Among the materials tested, endodontically treated teeth restored with everX posterior fiber reinforced composite showed superior fracture resistance. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  3. Measuring acetabular component position on lateral radiographs - ischio-lateral method.

    PubMed

    Pulos, Nicholas; Tiberi Iii, John V; Schmalzried, Thomas P

    2011-01-01

    The standard method for the evaluation of arthritis and postoperative assessment of arthroplasty treatment is observation and measurement from plain films, using the flm edge for orientation. A more recent employment of an anatomical landmark, the ischial tuberosity, has come into use as orientation for evaluation and is called the ischio-lateral method. In this study, the use of this method was evaluated as a first report to the literature on acetabular component measurement using a skeletal reference with lateral radiographs. Postoperative radiographs of 52 hips, with at least three true lateral radiographs taken at different time periods, were analyzed. Component position was measured with the historical method (using the flm edge for orientation) and with the new method using the ischio-lateral method. The mean standard deviation (SD) for the historical approach was 3.7° and for the ischio-lateral method, 2.2° (p < 0.001). With the historical method, 19 (36.5%) hips had a SD greater than ± 4°, compared to six hips (11.5%) with the ischio-lateral method. By using a skeletal reference, the ischio-lateral method provides a more consistent measurement of acetabular component position. The high intra-class correlation coefficients for both intra- and inter-observer reliability indicate that the angle measured with this simple method, which employs no further technology, increased time, or cost, is consistent and reproducible for multiple observers.

  4. Non-hip, non-spine fractures drive healthcare utilization following a fracture: the Global Longitudinal study of Osteoporosis in Women (GLOW)

    PubMed Central

    Ioannidis, G.; Flahive, J.; Pickard, L.; Papaioannou, A.; Chapurlat, R. D.; Saag, K. G.; Silverman, S.; Anderson, F. A.; Gehlbach, S. H.; Hooven, F. H.; Boonen, S.; Compston, J. E.; Cooper, C.; Díez-Perez, A.; Greenspan, S. L.; LaCroix, A. Z.; Lindsay, R.; Netelenbos, J. C.; Pfeilschifter, J.; Rossini, M.; Roux, C.; Sambrook, P. N.; Siris, E. S.; Watts, N. B.

    2016-01-01

    Summary We evaluated healthcare utilization associated with treating different fracture types in over 51,000 women aged ≥55 years. Over the course of 1 year, there were five times more non-hip, non-spine fractures than hip or spine fractures, resulting in twice as many days of hospitalization and rehabilitation/nursing home care for non-hip, non-spine fractures. Purpose To evaluate the medical healthcare utilization associated with treating several types of fractures in women aged 55 years or older from various geographic regions. Methods Information from the Global Longitudinal study of Osteoporosis in Women (GLOW) was collected via self-administered patient questionnaires at baseline and year 1 (n=51,491). Self-reported clinically recognized low-trauma fractures at year 1 were classified as incident spine, hip, wrist/hand, arm/shoulder, pelvis, rib, leg, and other fractures. Healthcare utilization data were self-reported and included whether the fracture was treated at a doctor’s office/clinic or at a hospital. Patients were also asked if they had undergone surgery or been treated at a rehabilitation center or nursing home. Results Over the 1-year study period, there were 195 spine, 134 hip, and 1,654 non-hip, non-spine fractures. In the GLOW cohort, clinical vertebral fractures resulted in 617 days of hospitalization and 512 days of rehabilitation/nursing home care, while hip fractures accounted for 1,306 days of hospitalization and 1,650 days of rehabilitation/nursing home care. Of particular interest is the result that non-hip, non-spine fractures resulted in 3,805 days in hospital and 5,186 days of rehabilitation/nursing home care. Conclusions While hip and vertebral fractures are well recognized for their associated increase in health resource utilization, non-hip, non-spine fractures, by virtue of their 5-fold greater number, require significantly more healthcare resources. PMID:22525976

  5. Interlocking intramedullary nailing in distal tibial fractures.

    PubMed

    Tyllianakis, M; Megas, P; Giannikas, D; Lambiris, E

    2000-08-01

    This retrospective study examined the results of non-pilon fractures of the distal part of the tibia treated with interlocking intramedullary nailing. Seventy-three patients with equal numbers of fractures treated surgically between 1990 and 1998 were reviewed. Mean patient age was 39.8 years, and follow-up averaged 34.2 months. The AO fracture classification system was used. Concomitant fractures of the lateral malleolus were fixed. All but three fractures achieved union within 4.2 months on average. Satisfactory or excellent results were obtained in 86.3% of patients. These results indicate interlocking intramedullary nailing is a reliable method of treatment for these fractures and is characterized by high rates of union and a low incidence of complications.

  6. Figure-of-eight bandage versus arm sling for treating middle-third clavicle fractures in adults: study protocol for a randomised controlled trial.

    PubMed

    Lenza, Mario; Taniguchi, Luiz Fabiano Presente; Ferretti, Mario

    2016-05-04

    Fracture of the clavicle is common, accounting for 2.6 to 4.0 % of all fractures, with an overall incidence of 36.5 to 64 per 100,000 per year. Around 80 % of clavicle fractures occur in the middle third of the clavicle. Randomised controlled trials comparing treatment interventions have failed to indicate the best therapeutic practices for these fractures. The objective of this study is to evaluate the effects (benefits and harms) of two commonly-used conservative interventions: the figure-of-eight bandage versus the arm sling as treatments of middle-third clavicle fractures. This project has been designed as a single-centre, two-arm randomised controlled trial that will compare two interventions: figure-of-eight bandage versus the arm sling. We propose to recruit 110 adults, aged 18 years or older, with an acute (less than 10 days since injury) middle-third clavicle fracture. The primary outcomes to be evaluated will be function and/or disability measured by the Disability of the Arm, Shoulder, and Hand (DASH) questionnaire. In order to assess the secondary outcomes, the Modified University of California at Los Angeles (modified - UCLA) Shoulder Rating Scale will be used. The occurrence of pain (Visual Analogue Scale for pain (VAS)), treatment failure, adverse events and the ability to return to previous activities will also be recorded and evaluated as secondary outcomes. the primary outcome DASH score and the secondary outcomes - modified UCLA and VAS scores - will be analysed graphically. We will apply generalised mixed models with the intervention groups (two levels), and time-point assessments (seven levels) as fixed effects and patients as a random effect. According to the current literature there is very limited evidence from two small trials regarding the effectiveness of different methods of conservative interventions for treating clavicle fractures. This is the first randomised controlled trial comparing the figure-of-eight bandage versus the arm

  7. [Fracture Type and Injury-to-Surgery Interval as Risk Factors for Avascular Necrosis of the Femoral Head after Internal Fixation of Intracapsular Femoral Neck Fracture].

    PubMed

    Popelka, O; Skála-Rosenbaum, J; Bartoška, R; Waldauf, P; Krbec, M; Džupa, V

    2015-01-01

    The aim of the study was to investigate the occurrence of avascular necrosis (AVN) of the femoral head following the osteosynthesis of intracapsular fracture of the femoral neck in relation to the time interval between injury and surgery and the type of fracture. The data of patients with intracapsular fractures of the femoral neck surgically treated in the period from 2001 to 2011 were reviewed. Of 1555 patients treated for this fracture, 125 (7%) underwent osteosynthesis. The evaluated group included 115 patients who came for examination at one-year follow-up. There were 59 (52%) women and 56 (48%) men. Dynamic hip screw (DHS) osteosynthesis with an anti-rotation screw was performed in 103 patients and lag-screw osteosynthesis involving three parallel cannulated cancellous screws was employed in 12 patients. The patients were allocated to groups according to the injury-to-surgery interval and to sub-groups on the basis of the Garden classification of femoral fracture stage. In the group of 58 patients treated within 6 h of injury, AVN developed in 10 (17%). When the type of fracture was considered, 4% of the non-displaced fractures and 30% of the displaced fractures developed AVN. The patients with Garden stage I and II (non-displaced) fractures treated within 6 h of injury had a significantly lower risk of AVN development than those with Garden stage III or IV (displaced) fractures. The group treated between 6 and 24 post-injury hours comprised 21 patients, of whom four (19%) had AVN. In non-displaced and displaced fracture sub-groups, 25% of the patients in the former and 16% in the latter had AVN. The stage of displacement had no effect on AVN development. The two groups together (patients treated by 24 h) had a significantly lower AVN incidence than the patients treated after 24 h (p = 0.0025). In this group of 36 patients, 16 had AVN (44%) and the fracture stage made no significant difference (p = 0.6985; nondisplacement sub-group, 41%; displacement sub

  8. Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing.

    PubMed

    Korduba, Laryssa A; Essner, Aaron; Pivec, Robert; Lancin, Perry; Mont, Michael A; Wang, Aiguo; Delanois, Ronald E

    2014-10-01

    The effect of acetabular component positioning on the wear rates of metal-on-polyethylene articulations has not been extensively studied. Placement of acetabular cups at abduction angles of more than 40° has been noted as a possible reason for early failure caused by increased wear. We conducted a study to evaluate the effects of different acetabular cup abduction angles on polyethylene wear rate, wear area, contact pressure, and contact area. Our in vitro study used a hip joint simulator and finite element analysis to assess the effects of cup orientation at 4 angles (0°, 40°, 50°, 70°) on wear and contact properties. Polyethylene bearings with 28-mm cobalt-chrome femoral heads were cycled in an environment mimicking in vivo joint fluid to determine the volumetric wear rate after 10 million cycles. Contact pressure and contact area for each cup abduction angle were assessed using finite element analysis. Results were correlated with cup abduction angles to determine if there were any differences among the 4 groups. The inverse relationship between volumetric wear rate and acetabular cup inclination angle demonstrated less wear with steeper cup angles. The largest abduction angle (70°) had the lowest contact area, largest contact pressure, and smallest head coverage. Conversely, the smallest abduction angle (0°) had the most wear and most head coverage. Polyethylene wear after total hip arthroplasty is a major cause of osteolysis and aseptic loosening, which may lead to premature implant failure. Several studies have found that high wear rates for cups oriented at steep angles contributed to their failure. Our data demonstrated that larger cup abduction angles were associated with lower, not higher, wear. However, this potentially "protective" effect is likely counteracted by other complications of steep cup angles, including impingement, instability, and edge loading. These factors may be more relevant in explaining why implants fail at a higher rate if

  9. [Distal clavicle fractures. Classifications and management].

    PubMed

    Ockert, Ben; Wiedemann, E; Haasters, F

    2015-05-01

    Fractures of the distal third of the clavicle represent 10-30% of all clavicle fractures . Frequently, these fractures result in instability due to a combination of bony and ligamentous injury. Thus, assessment of the stability is essential for adequate treatment of these fractures. This article presents a review of the different classification systems for distal clavicle fractures with respect to anatomical and functional factors to allow for comprehensive assessment of stability. Furthermore, the different treatment options for each fracture type are analyzed. Fractures to the distal third of the clavicle without instability can be treated conservatively with satisfactory outcome. In contrast, instability may result in symptomatic non-union under conservative treatment; therefore, distal clavicle fractures with instability should be treated operatively with respect to the functional demands of the patient. Operative treatment with locked plating in combination with coracoclavicular fixation results in excellent functional results. Arthroscopically assisted fracture fixation may be beneficial in terms of a minimally invasive approach as well as assessment and treatment of associated glenohumeral lesions.

  10. Total medical costs of treating femoral neck fracture patients with hemi- or total hip arthroplasty: a cost analysis of a multicenter prospective study.

    PubMed

    Burgers, P T P W; Hoogendoorn, M; Van Woensel, E A C; Poolman, R W; Bhandari, M; Patka, P; Van Lieshout, E M M

    2016-06-01

    The aim of this study was to determine the total medical costs for treating displaced femoral neck fractures with hemi- or total hip arthroplasty in fit elderly patients. The mean total costs per patient at 2 years of follow-up were €26,399. These results contribute to cost awareness. The absolute number of hip fractures is rising and increases the already significant burden on society. The aim of this study was to determine the mean total medical costs per patient for treating displaced femoral neck fractures with hemi- or total hip arthroplasty in fit elderly patients. The population was the Dutch sample of an international randomized controlled trial consisting of femoral neck fracture patients treated with hemi- or total hip arthroplasty. Patient data and health care utilization were prospectively collected during a total follow-up period of 2 years. Costs were separated into costs for hospital care during primary stay, hospital costs for clinical follow-up, and costs generated outside the hospital during rehabilitation. Multiple imputations were used to account for missing data. Data of 141 participants (mean age 81 years) were included in the analysis. The 2-year mortality rate was 19 %. The mean total cost per patient after 10 weeks of follow-up was €15,216. After 1 and 2 years of follow-up the mean total costs were €23,869 and €26,399, respectively. Rehabilitation was the main cost determinant, and accounted for 46 % of total costs. Primary hospital admission days accounted for 22 % of the total costs, index surgery for 11 %, and physical therapy for 7 %. The main cost determinants for hemi- or total hip arthroplasty after treatment of displaced femoral neck fractures (€26,399 per patient until 2 years) were rehabilitation and nursing homes. Most of the costs were made in the first year. Reducing costs after hip fracture surgery should focus on improving the duration and efficiency of the rehabilitation phase.

  11. Decreased fracture rate, pharmacogenetics and BMD response in 79 Swedish children with osteogenesis imperfecta types I, III and IV treated with Pamidronate.

    PubMed

    Lindahl, K; Kindmark, A; Rubin, C-J; Malmgren, B; Grigelioniene, G; Söderhäll, S; Ljunggren, Ö; Åström, E

    2016-06-01

    Osteogenesis imperfecta (OI) is an inherited heterogeneous bone fragility disorder, usually caused by collagen I mutations. It is well established that bisphosphonate treatment increases lumbar spine (LS) bone mineral density (BMD), as well as improves vertebral geometry in severe OI; however, fracture reduction has been difficult to prove, pharmacogenetic studies are scarce, and it is not known at which age, or severity of disease, treatment should be initiated. COL1A1 and COL1A2 were analyzed in 79 children with OI (type I n=33, type III n=25 and type IV n=21) treated with Pamidronate. Data on LS BMD, height, and radiologically confirmed non-vertebral and vertebral fractures were collected prior to, and at several time points during treatment. An increase in LS BMD Z-score was observed for all types of OI, and a negative correlation to Δ LS BMD was observed for both age and LS BMD Z-score at treatment initiation. Supine height Z-scores were not affected by Pamidronate treatment, The fracture rate was reduced for all OI types at all time points during treatment (overall p<0.0003, <0.0001 and 0.0003 for all OI types I, III and IV respectively). The reduced fracture rate was maintained for types I and IV, while an additional decrease was observed over time for type III. The fracture rate was reduced also in individuals with continued low BMD after >4yrs Pamidronate. Twice as many boys as girls with OI type I were treated with Pamidronate, and the fracture rate the year prior treatment was 2.2 times higher for boys (p=0.0236). Greater Δ LS BMD, but smaller Δ fracture numbers were observed on Pamidronate for helical glycine mutations in COL1A1 vs. COL1A2. Vertebral compression fractures did not progress in any individual during treatment; however, they did not improve in 9%, and these individuals were all >11years of age at treatment initiation (p<0.0001). Pamidronate treatment in children with all types of OI increased LS BMD, decreased fracture rate, and improved

  12. Lateral Compression-I Pelvic Ring Injury: Not Benign to the Developing Fetus.

    PubMed

    Weinlein, John C; Mashru, Rakesh P; Perez, Edward A; Johnson, Sara E

    2018-02-01

    To determine whether certain patterns of pelvic ring injury are associated with more frequent intrauterine fetal demise (IUFD). Retrospective review. Level 1 trauma center. Of 44 pregnant patients with pelvic and/or acetabular fractures, 40 had complete records that allowed determination of fetal viability. χ2 tests were used for categorical variables (Fisher exact tests when expected cell counts were fewer than 5), and t tests were used for continuous variables. Fetal or maternal death. Sixteen patients had isolated acetabular fractures, 25 had isolated pelvic ring injuries, and 3 had acetabular fractures with concomitant pelvic ring injuries. Maternal and fetal mortality were 2% and 40%, respectively. No patients with isolated acetabular fractures experienced IUFD, compared with 68% (15/22) of those with isolated pelvic ring injuries (P < 0.0001). Eight (53%) of 15 IUFDs were associated with lateral compression (LC)-I pelvic ring injuries (Orthopaedic Trauma Association/Arbeitsgemeinschaft für Osteosynthesefragen 61-B2). Of the 13 LC-I pelvic ring injuries, 8 (62%) resulted in IUFD. Pelvic ring stability, Young-Burgess classification, and operative treatment were not associated with IUFD. Maternal Glasgow Coma Scale (average 13.2) and Injury Severity Score (average 18.2) at admission were predictive of IUFD. The most frequent pelvic fractures in gravid trauma patients are LC-I. Although the rate of maternal mortality was low, the risk of IUFD was quite high (40%). LC-I pelvic ring injuries often had catastrophic outcomes, with IUFD in 62% of cases. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  13. Early polyethylene wear and osteolysis with ABG acetabular cups (7- to 12-year follow-up).

    PubMed

    Badhe, Sachin; Livesley, Peter

    2006-02-01

    We reviewed 81 consecutive ABG I primary total hip replacements implanted in 72 patients between January 1993 and December 1998. The mean follow-up was 8.2 (range 7-12) years. There was significant polyethylene wear and osteolysis associated with the acetabular cup . The cumulative survival of the cup with revision being the end point at 8.2 years was 95.1% (95% CI: 92-97.6%). However, the cumulative survival of the cup with revision and aseptic loosening together was 72% (95% CI: 61-78%) and survival of the acetabular liner for wear was 62% (95% CI: 48-74%). Stem survival with revision being the end point was 100%. In spite of significant radiological failures of the cups, most patients remained asymptomatic. Though results of the ABG stems in this series were good, we advocate a regular follow-up of all these hips in view of the poor outcome of the cups.

  14. Early polyethylene wear and osteolysis with ABG acetabular cups (7- to 12-year follow-up)

    PubMed Central

    Livesley, Peter

    2005-01-01

    We reviewed 81 consecutive ABG I primary total hip replacements implanted in 72 patients between January 1993 and December 1998. The mean follow-up was 8.2 (range 7–12) years. There was significant polyethylene wear and osteolysis associated with the acetabular cup .The cumulative survival of the cup with revision being the end point at 8.2 years was 95.1% (95% CI: 92–97.6%). However, the cumulative survival of the cup with revision and aseptic loosening together was 72% (95% CI: 61–78%) and survival of the acetabular liner for wear was 62% (95% CI: 48–74%). Stem survival with revision being the end point was 100%. In spite of significant radiological failures of the cups, most patients remained asymptomatic. Though results of the ABG stems in this series were good, we advocate a regular follow-up of all these hips in view of the poor outcome of the cups. PMID:16283307

  15. Similar influence of stabilized alkaline and neutral sodium hypochlorite solutions on the fracture resistance of root canal-treated bovine teeth.

    PubMed

    Souza, Erick Miranda; Calixto, Amanda Martins; Lima, Camila Nara E; Pappen, Fernanda Geraldo; De-Deus, Gustavo

    2014-10-01

    Stabilizing sodium hypochlorite (NaOCl) at an alkaline pH is proposed to increase solution stability and tissue dissolution ability; however, a reduction on the flexural strength of dentin discs has been found to be a side effect. This study sought to determine whether a stabilized alkaline NaOCl reduces the fracture resistance of root canal-treated bovine teeth after root canal preparation compared with a neutral solution counterpart. The 4 anterior incisors were removed from 20 mandibular bovine jaws, and each 1 was randomly assigned to 1 of 4 groups (20 teeth each). Teeth were prepared with a sequence of 6 K-type files. The following experimental groups received a different irrigation regimen: G1: distilled water (negative control), G2: 5% NaOCl at a pH of 7.2, and G3: 5% NaOCl at a pH of 12.8; in the positive control group (G4), teeth remained untreated. The time of contact and volume of solution were carefully standardized. After bone and periodontal ligament simulation, teeth were subjected to a fracture resistance test. A significant difference was observed among the 4 groups tested (analysis of variance, P < .05). The 5% NaOCl groups (G2 and G3) presented significantly lower resistance to fracture than the control (G1 and G4) (Tukey test, P < .05). Both NaOCl solutions similarly reduced the fracture resistance at approximately 30% (Tukey test, P > .05). No differences were observed between positive and negative control groups (Tukey test, P > .05). Stabilized alkaline and neutral NaOCl solutions similarly reduced the fracture resistance of root canal-treated bovine teeth by about 30%. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. Occult Intertrochanteric Fracture Mimicking the Fracture of Greater Trochanter.

    PubMed

    Chung, Phil Hyun; Kang, Suk; Kim, Jong Pil; Kim, Young Sung; Lee, Ho Min; Back, In Hwa; Eom, Kyeong Soo

    2016-06-01

    Occult intertrochanteric fractures are misdiagnosed as isolated greater trochanteric fractures in some cases. We investigated the utility of three-dimensional computed tomography (3D-CT) and magnetic resonance imaging (MRI) in the diagnosis and outcome management of occult intertrochanteric fractures. This study involved 23 cases of greater trochanteric fractures as diagnosed using plain radiographs from January 2004 to July 2013. Until January 2008, 9 cases were examined with 3D-CT only, while 14 cases were screened with both 3D-CT and MRI scans. We analyzed diagnostic accuracy and treatment results following 3D-CT and MRI scanning. Nine cases that underwent 3D-CT only were diagnosed with isolated greater trochanteric fractures without occult intertrochanteric fractures. Of these, a patient with displacement received surgical treatment. Of the 14 patients screened using both CT and MRI, 13 were diagnosed with occult intertrochanteric fractures. Of these, 11 were treated with surgical intervention and 2 with conservative management. Three-dimensional CT has very low diagnostic accuracy in diagnosing occult intertrochanteric fractures. For this reason, MRI is recommended to confirm a suspected occult intertrochanteric fracture and to determine the most appropriate mode of treatment.

  17. Cup press fit in uncemented THA depends on sex, acetabular shape, and surgical technique.

    PubMed

    García-Rey, Eduardo; García-Cimbrelo, Eduardo; Cruz-Pardos, Ana

    2012-11-01

    Uncemented press-fit cups provide bone fixation in primary THA, but the use of screws is sometimes necessary to achieve primary stability of the socket. However, it is unclear whether and when screws should be used. We analyzed the factors related to screw use with a press-fit uncemented cup and assessed whether screw use is associated with the same rates of loosening and revision as a press-fit technique. We retrospectively reviewed 248 patients who underwent THA using the same prosthetic design. Eighty-eight hips had screws to achieve primary cup fixation (Group 1), and 189 did not (Group 2). Mean age was 50 years (range, 14-73 years). We analyzed factors related to the patient, acetabular type, and reconstruction of the rotation center of the hip. Minimum followup was 5 years (mean, 8.9 years; range, 5-12 years). We found higher screw use in women, patients with less physical activity, Acetabular Types A or C, and a distance from the center of the prosthetic femoral head to the normal center of rotation of more than 3 mm. There were four revisions in Group 1 and five in Group 2. Eight hips had radiographic loosening in Group 1 and nine in Group 2. Cups with a postoperative abduction angle of more than 50° had a higher risk for loosening. Press fit was achieved less frequently in women and patients with Acetabular Types A or C and less physical activity; a closer distance to the normal center of rotation decreased screw use. Screw use to augment fixation achieved survival similar to that of a press-fit cup. Level II, prognostic study. See Instructions for Authors for a complete description of levels of evidence.

  18. Post-deformation shape-recovery behavior of vitamin E-diffused, radiation crosslinked polyethylene acetabular components.

    PubMed

    Takahashi, Yasuhito; Tateiwa, Toshiyuki; Shishido, Takaaki; Masaoka, Toshinori; Kubo, Kosuke; Yamamoto, Kengo

    2016-10-01

    The in-vivo progression of creep and wear in ultra-high molecular weight polyethylene (UHMWPE) acetabular liners has been clinically evaluated by measuring radiographic penetration of femoral heads. In such clinical assessments, however, viscoelastic strain relaxation has been rarely considered after a removal of hip joint loading, potentially leading to an underestimation of the penetrated thickness. The objective of this study was to investigate shape-recovery behavior of pre-compressed, radiation crosslinked and antioxidant vitamin E-diffused UHMWPE acetabular liners, and also to characterize the effects of varying their internal diameter (ID) and wall thickness (WT). We applied uniaxial compression to the UHMWPE specimens of various ID (28, 32, 36mm) and WT (4.8, 6.8, 8.9mm) for 4320min under the constant load of 3000N, and subsequently monitored the strain-relaxation behavior as a function of time after unloading. It was observed that there was a considerable shape recovery of the components after removal of the external static load. Reducing ID and WT significantly accelerated the rate of creep strain recovery, and varying WT was more sensitive to the recovery behavior than ID. Creep deformation of the tested liners recovered mostly within the first 300min after unloading. Note that approximately half of the total recovery amount proceeded just within 5min after unloading. These results suggest a remarkably high capability of shape recovery of vitamin E-diffused highly crosslinked UHMWPE. In conclusion, the time-dependent shape recovering and the diameter-thickness effect on its behavior should be carefully considered when the postoperative penetration is quantified in highly crosslinked UHMWPE acetabular liners (especially on the non-weight bearing radiographs). Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Outcome of limb fracture repair in rabbits: 139 cases (2007-2015).

    PubMed

    Sasai, Hiroshi; Fujita, Daisuke; Seto, Eiko; Denda, Yuki; Imai, Yutaro; Okamoto, Kanako; Okamura, Kensaku; Furuya, Masaru; Tani, Hiroyuki; Sasai, Kazumi

    2018-02-15

    OBJECTIVE To evaluate outcome of limb fracture repair in rabbits. DESIGN Retrospective case series. ANIMALS 139 client-owned rabbits with limb fractures treated between 2007 and 2015. PROCEDURES Medical records were reviewed for information on fracture location, fracture treatment, and time to fracture healing. RESULTS 25 rabbits had fractures involving the distal aspects of the limbs (ie, metacarpal or metatarsal bones, phalanges, and calcaneus or talus). Fractures were treated in 23 of these 25 rabbits (external coaptation, n = 17; external skeletal fixation, 4; and intramedullary pinning, 2) and healed in all 23, with a median healing time of 28 days (range, 20 to 45 days). One hundred ten rabbits had long bone fractures, and fractures were treated in 100 of the 110 (external skeletal fixation, n = 89; bone plating, 1; intramedullary pinning, 3; and external coaptation, 7). The percentage of fractures that healed was significantly lower for open (14/18) than for closed (26/26) tibial fractures and was significantly lower for femoral (19/26) and treated humeral (4/6) fractures than for radial (23/24) or closed tibial (26/26) fractures. Micro-CT was used to assess fracture realignment during external skeletal fixator application and to evaluate fracture healing. CONCLUSIONS AND CLINICAL RELEVANCE The prognosis for rabbits with limb fractures was good, with fractures healing in most rabbits following fracture repair (109/123). Micro-CT was useful in assessing fracture realignment and evaluating fracture healing.

  20. The treatment options for posterior malleolar fractures in tibial spiral fractures.

    PubMed

    Guo, Jialiang; Liu, Lei; Yang, Zongyou; Hou, Zhiyong; Chen, Wei; Zhang, Yingze

    2017-09-01

    The posterior malleolar fracture (PMF) in tibial spiral fractures are a common type of complication that occurs in tibial fractures. However, the indication of fixation for posterior fractures is still under debate and varies between different surgeons'. It is not unusual to find the smaller PMF (<25%), which could be treated conservatively within guidelines, treated with internal fixation in clinic. The aim of this study is to evaluate the clinical outcomes of tibial spiral fractures with PMF and provide proper guidance for the treatment of this special fracture. A total of 284 cases of spiral fractures combined with PMF were collected and analyzed. Demographic data, fragment size (classified by 25% involvement of ankle joint), time to weight-bearing and functional scores post-operatively were recorded. The ankle-hindfoot scale of the American Orthopaedic Foot and Ankle Society (AOFAS), a visual analogue scale (VAS) pain score, assessment of dorsiflexion restriction and arthritis scale were used as the main evaluations. Forty patients with a larger PMF (≥25%) and 72 with smaller ones (<25%) were fixed and categorized as the fixation group (FG). In the nonfixation group (NG), the corresponding numbers were four and 168 patients respectively. A total of 279 PMF were classified as large posterolateral triangular fragment carrying the posterior half of the fibular notch and intra-incisural posterolateral fragment involving one-fourth to one-third of the fibular notch. However, no obvious differences were observed in terms of the clinical outcomes in PMF involving one-fourth to one-third of the fibular notch. In the treatment of smaller PMF (<25%) of this type, there were no obvious differences in the functional outcomes between fixed (SF) and nonfixed PMF (SN). Many patients with smaller PMFs were fixated, but functional outcomes of SF were not better than those of SN. There is no need to emphasize other factors guiding the treatment of PMF involving one-fourth to

  1. Occupational therapy and Colles' fractures.

    PubMed

    Christensen, O M; Kunov, A; Hansen, F F; Christiansen, T C; Krasheninnikoff, M

    2001-01-01

    In this randomized trial, we enrolled 30 patients treated for a distal radius Colles' type fracture. The fractures were reduced if necessary and fixed in a below-elbow plaster cast for 5 weeks. One group consisting of 14 patients received instructions for shoulder; elbow and finger exercise and the other group consisting of 16 patients had occupational therapy. At 5 weeks, 3 and 9 months we measured the functional scores. There were no statistically significant differences between the groups at any time. It seems that for non-surgically treated patients with a distal radius fracture only instructions are necessary.

  2. Operative treatment of hip fractures in patients receiving hemodialysis.

    PubMed

    Tosun, Bilgehan; Atmaca, Halil; Gok, Umit

    2010-11-01

    Fifteen hips in 13 patients with hip fracture were treated in patients receiving hemodialysis for chronic renal failure. There were four intertrochanteric and 11 femoral neck fractures. 10 of the 11 femoral neck fractures and one of the four intertrochanteric fractures were treated with cemented bipolar hemiarthroplasty. Two intertrochanteric fractures fixed with sliding compression screws. External fixation was used for stabilization in two patients who had femoral neck and intertrochanteric fractures. Two intertrochanteric fractures that were treated with sliding hip screw showed radiological union postoperatively at the 6th month. Of the 11 hemiarthroplasty, four hips developed aseptic loosening (36%). According to Harris hip score grading system, three (37.5%) poor, two (25%) fair, two (25%) good and one (12.5%) case had excellent outcome in the hemiarthroplasty group. The survival of dialysis patients with a hip fracture is markedly reduced. Initial treatment of hemiarthroplasty allows early mobilization and prevents revision surgery.

  3. Isolated olecranon fractures in children affected by osteogenesis imperfecta type I treated with single screw or tension band wiring system: Outcomes and pitfalls in relation to bone mineral density.

    PubMed

    Persiani, Pietro; Ranaldi, Filippo M; Graci, Jole; De Cristo, Claudia; Zambrano, Anna; D'Eufemia, Patrizia; Martini, Lorena; Villani, Ciro

    2017-05-01

    The purpose of this study is to compare the results of 2 techniques, tension band wiring (TBW) and fixation with screws, in olecranon fractures in children affected with osteogenesis imperfecta (OI) type I. Between 2010 and 2014, 21 olecranon fractures in 18 children with OI (average age: 12 years old) were treated surgically. Ten patients were treated with the screw fixation and 11 with TBW. A total of 65% of olecranon fractures occurred as a result of a spontaneous avulsion of the olecranon during the contraction of the triceps muscle. The average follow-up was 36 months. Among the children treated with 1 screw, 5 patients needed a surgical revision with TBW due to a mobilization of the screw. In this group, the satisfactory results were 50%. In patients treated with TBW, the satisfactory results were 100% of the cases. The average Z-score, the last one recorded in the patients before the trauma, was -2.53 in patients treated with screw fixation and -2.04 in those treated with TBW. TBW represents the safest surgical treatment for patients suffering from OI type I, as it helps to prevent the rigidity of the elbow through an earlier recovery of the range of motion, and there was no loosening of the implant. In analyzing the average Z-score before any fracture, the fixation with screws has an increased risk of failure in combination with low bone mineral density.

  4. Single-incision approach improves wound healing and bone union for treating mid-to-lower segment of tibiofibular fracture.

    PubMed

    Zhang, Yongguang; Zhuang, Yuehong; Wang, Benhai; Xu, Hao; Chen, Jinshui; Lin, Songqing

    2015-01-01

    The mid-to-lower segment of tibiofibular fractures (MLTFs) is commonly encountered in clinical practice, which is conventionally treated by the double-incision surgical approach. However, the double-incision approach frequently makes the closure of the wound extremely difficult and sometimes results in necrosis of skin around fractured sites. In the present study, our experience of using a single-incision surgical approach for treating MLTF was exhibited. From February 2005 to December 2013, the clinical outcomes of 212 patients with MLTFs who underwent either double-incision approach or single-incision approach were retrospectively evaluated and compared. Both groups were similar with respect to injury mechanism and all patients were followed up with the efficacies of treatment evaluated by Johner-Wruth criteria. The results demonstrated that the effective rate and the rate of excellent and good efficacy in the single-incision group were significantly higher than those in the double-incision group (P<0.05). In addition, the rates of skin wound healing and bone union after surgery in the single-incision group were significantly higher than those in the double-incision group (P<0.05). These findings indicate that the single-incision surgical approach, which holds the advantages of being milder in trauma, fewer in complications and better in function restoration, might be used as an alternative method for treating MLTFs.

  5. What Safe Zone? The Vast Majority of Dislocated THAs Are Within the Lewinnek Safe Zone for Acetabular Component Position.

    PubMed

    Abdel, Matthew P; von Roth, Philipp; Jennings, Matthew T; Hanssen, Arlen D; Pagnano, Mark W

    2016-02-01

    Numerous factors influence total hip arthroplasty (THA) stability including surgical approach and soft tissue tension, patient compliance, and component position. One long-held tenet regarding component position is that cup inclination and anteversion of 40° ± 10° and 15° ± 10°, respectively, represent a "safe zone" as defined by Lewinnek that minimizes dislocation after primary THA; however, it is clear that components positioned in this zone can and do dislocate. We sought to determine if these classic radiographic targets for cup inclination and anteversion accurately predicted a safe zone limiting dislocation in a contemporary THA practice. From a cohort of 9784 primary THAs performed between 2003 and 2012 at one institution, we retrospectively identified 206 THAs (2%) that subsequently dislocated. Radiographic parameters including inclination, anteversion, center of rotation, and limb length discrepancy were analyzed. Mean followup was 27 months (range, 0-133 months). The majority (58% [120 of 206]) of dislocated THAs had a socket within the Lewinnek safe zone. Mean cup inclination was 44° ± 8° with 84% within the safe zone for inclination. Mean anteversion was 15° ± 9° with 69% within the safe zone for anteversion. Sixty-five percent of dislocated THAs that were performed through a posterior approach had an acetabular component within the combined acetabular safe zones, whereas this was true for only 33% performed through an anterolateral approach. An acetabular component performed through a posterior approach was three times as likely to be within the combined acetabular safe zones (odds ratio [OR], 1.3; 95% confidence interval [CI], 1.1-1.6) than after an anterolateral approach (OR, 0.4; 95% CI, 0.2-0.7; p < 0.0001). In contrast, acetabular components performed through a posterior approach (OR, 1.6; 95% CI, 1.2-1.9) had an increased risk of dislocation compared with those performed through an anterolateral approach (OR, 0.8; 95% CI, 0.7-0.9; p

  6. Surgery for pathological proximal femoral fractures, excluding femoral head and neck fractures: resection vs. stabilisation.

    PubMed

    Zacherl, Max; Gruber, Gerald; Glehr, Mathias; Ofner-Kopeinig, Petra; Radl, Roman; Greitbauer, Manfred; Vecsei, Vilmos; Windhager, Reinhard

    2011-10-01

    Pathological femoral head and neck fractures are commonly treated by arthroplasty. Treatment options for the trochanteric region or below are not clearly defined. The purpose of this retrospective, comparative, double-centre study was to analyse survival and influences on outcome according to the surgical technique used to treat pathological proximal femoral fractures, excluding fractures of the femoral head and neck. Fifty-nine patients with 64 fractures were operated up on between 1998 and 2004 in two tertiary referral centres and divided into two groups. One group (S, n = 33) consisted of patients who underwent intramedullary nailing alone, and the other group (R, n = 31) consisted of patients treated by metastatic tissue resection and reconstruction by means of different implants. Median survival was 12.6 months with no difference between groups. Surgical complications were higher in the R group (n = 7) vs. the S group (n = 3), with no statistically significant difference. Patients with surgery-related complications had a higher survival rate (p = 0.049), as did patients with mechanical implant failure (p = 0.01). Survival scoring systems did not correlate with actual survival. Resection of metastases in patients with pathological fractures of the proximal femur, excluding femoral head and neck fractures, has no influence on survival. Patients with long postoperative survival prognosis are at risk of implant-related complications.

  7. Nine Year Follow-up of a Ceramic-on-Ceramic Bearing Total Hip Arthroplasty Utilizing a Layered Monoblock Acetabular Component

    PubMed Central

    Mayor, David; Patel, Savan; Perry, Clayton; Walter, Norman; Burton, Stephen; Atkinson, Theresa

    2014-01-01

    Introduction Early ceramic bearing systems in total hip arthoplasty (THA) sought to provide long term wear improvement over traditional metal on polyethylene systems. However, previous designs exhibited fractures of the ceramic acetabular liner, leading to the development of the Implex Hedrocel ceramic bearing THA system where the ceramic liner was supported on a layer of polyethylene intended to transition liner loads to the metal shell, a so-called “sandwich” design. Unfortunately, the device trial was stopped to further enrollment when liner fractures were reported. The current study examines nearly 10-year follow-up on 28 devices implanted by two surgeons at one institution in order to document ceramic bearing system performance over a longer time period. Methods Radiographic and patient reported outcomes, in the form of Harris Hip Scores (HHS) and 12-Item Short Form Health Survey (sF-12), were collected. Results During the study period two cups were replaced, one at three years and a second at seven years. At the five year follow-up HHS were similar to those reported in the literature for devices with traditional metal-on-polyethylene bearing surfaces and for other sandwich ceramic bearing designs. At the nine year follow-up, the HHS had not changed significantly and SF-12 scores measuring overall physical and mental health were higher than age matched national norms (p<0.001). There were no signs of cup migration, stem subsidence, osteolysis or cup loosening at any time up to the last follow-up in this patient cohort. The 89% survivorship rate and device revisions due to delamination of the liner observed in this group were similar to those reported earlier for this device and for other “sandwich design” ceramic bearing systems. Discussion This cohort did not exhibit new failure modes and HHS and SF-12 scores indicated high functionality for the majority of patients. These data suggest that a focus on preventing ceramic liner fracture through design

  8. [Treatment of metacarpal fractures].

    PubMed

    Prokop, A; Jubel, A; Helling, H J; Kulus, S; Rehm, K E

    2002-09-01

    Conservative treatment of metacarpal fractures is recommended if there is no joint displacement, malrotation, displacement of over 30 degrees ad axim and shortening of over 5 mm. Surgery should be performed in open fractures and serial fractures of metacarpal bone. Early functional treatment should be carried out in stable, not displaced fractures. A cast can be used for a short period in full extended position of fingers and flexion in metacarpo-phalangeal joint in 60 - 90 degrees. Twin-tape fixation allows functional treatment after soft-tissue swelling has disappeared. Closed reduction of displaced fractures of the fifth metacarpal bone (boxer's fracture) is not successful. Cases with displacement of over 30 degrees may be treated surgically by intramedullary stabilisation.

  9. Advances in treating exposed fractures.

    PubMed

    Nogueira Giglio, Pedro; Fogaça Cristante, Alexandre; Ricardo Pécora, José; Partezani Helito, Camilo; Lei Munhoz Lima, Ana Lucia; Dos Santos Silva, Jorge

    2015-01-01

    The management of exposed fractures has been discussed since ancient times and remains of great interest to present-day orthopedics and traumatology. These injuries are still a challenge. Infection and nonunion are feared complications. Aspects of the diagnosis, classification and initial management are discussed here. Early administration of antibiotics, surgical cleaning and meticulous debridement are essential. The systemic conditions of patients with multiple trauma and the local conditions of the limb affected need to be taken into consideration. Early skeletal stabilization is necessary. Definitive fixation should be considered when possible and provisional fixation methods should be used when necessary. Early closure should be the aim, and flaps can be used for this purpose.

  10. Intrinsic mechanical behavior of femoral cortical bone in young, osteoporotic and bisphosphonate-treated individuals in low- and high energy fracture conditions

    NASA Astrophysics Data System (ADS)

    Zimmermann, Elizabeth A.; Schaible, Eric; Gludovatz, Bernd; Schmidt, Felix N.; Riedel, Christoph; Krause, Matthias; Vettorazzi, Eik; Acevedo, Claire; Hahn, Michael; Püschel, Klaus; Tang, Simon; Amling, Michael; Ritchie, Robert O.; Busse, Björn

    2016-02-01

    Bisphosphonates are a common treatment to reduce osteoporotic fractures. This treatment induces osseous structural and compositional changes accompanied by positive effects on osteoblasts and osteocytes. Here, we test the hypothesis that restored osseous cell behavior, which resembles characteristics of younger, healthy cortical bone, leads to improved bone quality. Microarchitecture and mechanical properties of young, treatment-naïve osteoporosis, and bisphosphonate-treated cases were investigated in femoral cortices. Tissue strength was measured using three-point bending. Collagen fibril-level deformation was assessed in non-traumatic and traumatic fracture states using synchrotron small-angle x-ray scattering (SAXS) at low and high strain rates. The lower modulus, strength and fibril deformation measured at low strain rates reflects susceptibility for osteoporotic low-energy fragility fractures. Independent of age, disease and treatment status, SAXS revealed reduced fibril plasticity at high strain rates, characteristic of traumatic fracture. The significantly reduced mechanical integrity in osteoporosis may originate from porosity and alterations to the intra/extrafibrillar structure, while the fibril deformation under treatment indicates improved nano-scale characteristics. In conclusion, losses in strength and fibril deformation at low strain rates correlate with the occurrence of fragility fractures in osteoporosis, while improvements in structural and mechanical properties following bisphosphonate treatment may foster resistance to fracture during physiological strain rates.

  11. Managing Complications of Calcaneus Fractures.

    PubMed

    Clare, Michael P; Crawford, William S

    2017-03-01

    Calcaneus fractures remain among the most complicated fractures for orthopedic surgeons to manage because of the complexity of various fracture patterns, the limited surrounding soft tissue envelope, and the prolonged rehabilitation issues impacting function after successful treatment. Despite this, appropriate management of complications associated with calcaneus fractures is critical for the complete care of this injury, whether treated operatively or nonoperatively. The authors present the common complications encountered with fractures of the calcaneus and management thereof. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Occult Intertrochanteric Fracture Mimicking the Fracture of Greater Trochanter

    PubMed Central

    Chung, Phil Hyun; Kang, Suk; Kim, Jong Pil; Kim, Young Sung; Back, In Hwa; Eom, Kyeong Soo

    2016-01-01

    Purpose Occult intertrochanteric fractures are misdiagnosed as isolated greater trochanteric fractures in some cases. We investigated the utility of three-dimensional computed tomography (3D-CT) and magnetic resonance imaging (MRI) in the diagnosis and outcome management of occult intertrochanteric fractures. Materials and Methods This study involved 23 cases of greater trochanteric fractures as diagnosed using plain radiographs from January 2004 to July 2013. Until January 2008, 9 cases were examined with 3D-CT only, while 14 cases were screened with both 3D-CT and MRI scans. We analyzed diagnostic accuracy and treatment results following 3D-CT and MRI scanning. Results Nine cases that underwent 3D-CT only were diagnosed with isolated greater trochanteric fractures without occult intertrochanteric fractures. Of these, a patient with displacement received surgical treatment. Of the 14 patients screened using both CT and MRI, 13 were diagnosed with occult intertrochanteric fractures. Of these, 11 were treated with surgical intervention and 2 with conservative management. Conclusion Three-dimensional CT has very low diagnostic accuracy in diagnosing occult intertrochanteric fractures. For this reason, MRI is recommended to confirm a suspected occult intertrochanteric fracture and to determine the most appropriate mode of treatment. PMID:27536653

  13. Comparison of surgical techniques of 111 medial malleolar fractures classified by fracture geometry.

    PubMed

    Ebraheim, Nabil A; Ludwig, Todd; Weston, John T; Carroll, Trevor; Liu, Jiayong

    2014-05-01

    Evaluation of operative techniques used for medial malleolar fractures by classifying fracture geometry has not been well documented. One hundred eleven patients with medial malleolar fractures (transverse n = 63, oblique n = 29, vertical n = 7, comminuted n = 12) were included in this study. Seventy-two patients had complicating comorbidities. All patients were treated with buttress plate, lag screw, tension band, or K-wire fixation. Treatment outcomes were evaluated on the basis of radiological outcome (union, malunion, delayed union, or nonunion), need for operative revision, presence of postoperative complications, and AOFAS Ankle-Hindfoot score. For transverse fractures, tension band fixation showed the highest rate of union (79%), highest average AOFAS score (86), lowest revision rate (5%), and lowest complication rate (16%). For oblique fractures, lag screws showed the highest rate of union (71%), highest average AOFAS score (80), lowest revision rate (19%), and lowest complication rate (33%) of the commonly used fixation techniques. For vertical fractures, buttress plating was used in every case but 1, achieving union (whether normal or delayed) in all cases with an average AOFAS score of 84, no revisions, and a 17% complication rate. Comminuted fractures had relatively poor outcomes regardless of fixation method. The results of this study suggest that both tension bands and lag screws result in similar rates of union for transverse fractures of the medial malleolus, but that tension band constructs are associated with less need for revision surgery and fewer complications. In addition, our data demonstrate that oblique fractures were most effectively treated with lag screws and that vertical fractures attained superior outcomes with buttress plating. Level III, retrospective comparative series.

  14. Does age affect outcome in children with clavicle fracture treated conservatively? QuickDash and MRC evaluation of 131 consecutive cases.

    PubMed

    Pavone, Vito; DE Cristo, Claudia; Testa, Gianluca; Canavese, Federico; Lucenti, Ludovico; Sessa, Giuseppe

    2018-04-12

    Non-operative treatment with immobilization is the gold-standard for paediatric clavicular fractures. Purpose of this study is to evaluate functional outcomes and efficacy of non-operative treatment of clavicular fractures in a succession of 131 children. Between 2006 and 2012, we treated non-surgically 131 children for a clavicular fracture. All fractures have been classified according to Robinson classification. Clavicle shortening, range of movements and muscular strength through the Medical Research Council (MRC) scale were evaluated. To assess the outcomes, QuickDASH questionnaire, dividing the sample in 3 age-related group, was administered. The average follow-up was 26 months (8-84 months). Clavicle shortening at the time of injury occurred in 18 cases. All fractures reached union. Average time to union was 34 days. Mean time return to activity was 12.6 weeks. No cases of nonunion or delayed union were reported. Complications occurred in 21 cases. A shortening persisted in 2 cases. Only one patient had a slight functional restriction. Average QuickDASH score was 6.2±1.1 (range 4.3-9.4). All patients recovered to a MRC score of 5, except for one patient with a score of 4. Best QuickDASH scores were observed in the group aged under 8 years and in non-comminuted and lateral third fractures of the clavicle. Observing results, clavicle fractures have a satisfactory clinical healing as shown by the good scores at QuickDASH and MRC scale. Younger children under 8 years can achieve the best results with a conservative treatment in terms of bone healing and activity level.

  15. Outcomes of dual-mobility acetabular cup for instability in primary and revision total hip arthroplasty.

    PubMed

    Mohammed, Riazuddin; Hayward, Keith; Mulay, Sanjay; Bindi, Frank; Wallace, Murray

    2015-03-01

    The concept of a dual-mobility hip socket involves the standard femoral head component encased in a larger polyethylene liner, which in turn articulates inside a metal shell implanted in the native acetabulum. The aim of this study was to assess outcomes from using a Serf Novae(®) Dual Mobility Acetabular cup (Orthodynamics Ltd, Gloucestershire, UK) to address the problem of instability in primary and revision total hip arthroplasty (THA). A retrospective review was carried out of all hip arthroplasties performed in a District General Hospital utilising the dual-mobility socket from January 2007 to December 2012. Clinical and radiological outcomes were analysed for 44 hips in 41 patients, comprising 20 primary and 24 revision THA. The average age of the study group was 70.8 years (range 56-84 years) for primary and 76.4 years (range 56-89 years) for revision arthroplasty. Among the primary THA, always performed for hip osteoarthritis or in presence of osteoarthritic changes, the reasons to choose a dual mobility cup were central nervous system problems such as Parkinson's disease, stroke, dementia (10), hip fracture (5), failed hip fracture fixation (2), severe fixed hip deformity (2) and diffuse peripheral neuropathy (1). The indications for revisions were recurrent dislocation (17), aseptic loosening with abductor deficiency (4), failed hemiarthroplasty with abductor deficiency (2) and neglected dislocation (1). At a mean follow-up of 22 months (range 6-63 months), none of the hips had any dislocation, instability or infection and no further surgical intervention was required. Radiological assessment showed that one uncemented socket in a revision arthroplasty performed for recurrent dislocation had changed position, but was stable in the new position. The patient did not have complications from this and did not need any surgical intervention. Even though postoperative hip stability depends on several factors other than design-related ones, our study shows

  16. Emergency department recidivism in adults older than 65 years treated for fractures.

    PubMed

    Southerland, Lauren T; Richardson, Daniel S; Caterino, Jeffrey M; Essenmacher, Alex C; Swor, Robert A

    2014-09-01

    Fractures in older adults are a commonly diagnosed injury in the emergency department (ED). We performed a retrospective medical record review to determine the rate of return to the same ED within 72 hours (returns) and the risk factors associated with returning. A retrospective medical record review of patients at least 65 years old discharged from a large, academic ED with a new diagnosis of upper extremity, lower extremity, or rib fractures was performed. Risk factors analyzed included demographic data, type of fracture, analgesic prescriptions, assistive devices provided, other concurrent injuries, and comorbidities (Charlson Comorbidity Index). Our primary outcome was return to the ED within 72 hours. Three hundred fifteen patients qualified. Most fractures were in the upper extremity (64% [95% confidence interval {CI}, 58%-69%]). Twenty patients (6.3% [95% CI, 3.9%-9.6%]) returned within 72 hours. Most returns (15/20, 75%) were for reasons associated with the fracture itself, such as cast problems and inadequate pain control. Only 3 (<1% of all patients) patients returned for cardiac etiologies. Patients with distal forearm fractures had higher return rates (10.7% vs 4.5%, P = .03), and most commonly returned for cast or splint problems. Age, sex, other injuries, assistive devices, and Charlson Comorbidity Index score (median, 1 [interquartile range, 1-2] for both groups) did not predict 72-hour returns. Older adults with distal forearm fractures may have more unscheduled health care usage in the first 3 days after fracture diagnosis than older adults with other fracture types. Overall, revisits for cardiac reasons or repeat falls were rare (<1%). Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Clinical effects of internal fixation for ulnar styloid fractures associated with distal radius fractures: A matched case-control study.

    PubMed

    Sawada, Hideyoshi; Shinohara, Takaaki; Natsume, Tadahiro; Hirata, Hitoshi

    2016-11-01

    Ulnar styloid fractures are often associated with distal radius fractures. However, controversy exists regarding whether to treat ulnar styloid fractures. This study aimed to evaluate clinical effects of internal fixation for ulnar styloid fractures after distal radius fractures were treated with the volar locking plate system. We used prospectively collected data of distal radius fractures. 111 patients were enrolled in this study. A matched case-control study design was used. We selected patients who underwent fixation for ulnar styloid fractures (case group). Three control patients for each patient of the case group were matched on the basis of age, sex, and fracture type of distal radius fractures from among patients who did not undergo fixation for ulnar styloid fractures (control group). The case group included 16 patients (7 men, 9 women; mean age: 52.6 years; classification of ulnar styloid fractures: center, 3; base, 11; and proximal, 2). The control group included 48 patients (15 men, 33 women; mean age: 61.1 years; classification of ulnar styloid fractures: center, 10; base, 31; and proximal, 7). For radiographic examination, the volar tilt angle, radial inclination angle, and ulnar variance length were measured, and the union of ulnar styloid fractures was judged. For clinical examination, the range of motions, grip strength, Hand20 score, and Numeric Rating Scale score were evaluated. There was little correction loss for each radiological parameter of fracture reduction, and these parameters were not significantly different between the groups. The bone-healing rate of ulnar styloid fractures was significantly higher in the case group than in the control group, but the clinical results were not significantly different. We revealed that there was no need to fix ulnar styloid fractures when distal radius fractures were treated via open reduction and internal fixation with a volar locking plate system. Copyright © 2016 The Japanese Orthopaedic Association

  18. Performance-based Outcomes of Inpatient Rehabilitation Facilities Treating Hip Fracture Patients in the United States

    PubMed Central

    Baernholdt, Marianne; Anderson, Ruth A.; Merwin, Elizabeth I.

    2015-01-01

    Objective To examine the influence of facility and aggregate patient characteristics of inpatient rehabilitation facilities (IRFs) on performance-based rehabilitation outcomes in a national sample of IRFs treating Medicare beneficiaries with hip fracture. Design Secondary data analysis. Setting U.S. Medicare-certified IRFs (N=983). Participants 983 US Medicare-certified IRFs. Data included 34,364 patient records of Medicare beneficiaries admitted in 2009 for rehabilitation after hip fracture. Main Outcome Measures Performance-based outcomes included mean motor function on discharge, mean motor change (mean motor score on discharge minus mean motor score on admission) and percentage discharged to the community. Results Higher mean motor function on discharge was explained by aggregate characteristics of hip fracture patients (lower age [p=0.009], lower percentage of Blacks [p<0.001] and Hispanics [p<0.001], higher percentage of females [p<0.030], higher motor function on admission [p<0.001], longer length of stay [p<0.001]) and facility characteristics (freestanding [p<0.001], rural [p<0.001], for-profit [p=0.048], and smaller IRFs [p=0.041]). The findings were similar for motor change, but motor change was also associated with lower mean cognitive function on admission (0.008). Higher percentage discharged to the community was associated with aggregate patient characteristics (lower age [p<0.001], lower percentage of Hispanics [p=0.009], higher percentage of patients living with others [p<0.001], and higher motor function on admission [p<0.001]). No facility characteristics were associated with percentage discharged to the community. Conclusion Performance-based measurement offers health policymakers, administrators, clinicians, and consumers a major opportunity for securing health system improvement by benchmarking or comparing their outcomes to other similar facilities. These results might serve as the basis for benchmarking and quality-based reimbursement to

  19. Bone Repair on Fractures Treated with Osteosynthesis, ir Laser, Bone Graft and Guided Bone Regeneration: Histomorfometric Study

    NASA Astrophysics Data System (ADS)

    dos Santos Aciole, Jouber Mateus; dos Santos Aciole, Gilberth Tadeu; Soares, Luiz Guilherme Pinheiro; Barbosa, Artur Felipe Santos; Santos, Jean Nunes; Pinheiro, Antonio Luiz Barbosa

    2011-08-01

    The aim of this study was to evaluate, through the analysis of histomorfometric, the repair of complete tibial fracture in rabbits fixed with osteosynthesis, treated or not with infrared laser light (λ780 nm, 50 mW, CW) associated or not to the use of hydroxyapatite and guided bone regeneration (GBR). Surgical fractures were created, under general anesthesia (Ketamina 0,4 ml/Kg IP and Xilazina 0,2 ml/Kg IP), on the dorsum of 15 Oryctolagus rabbits that were divided into 5 groups and maintained on individual cages, at day/night cycle, fed with solid laboratory pelted diet and had water ad libidum. On groups II, III, IV and V the fracture was fixed with wire osteosynthesis. Animals of groups III and V were grafted with hydroxyapatite and GBR technique used. Animals of groups IV and V were irradiated at every other day during two weeks (16 J/cm2, 4×4 J/cm2). Observation time was that of 30 days. After animal death (overdose of general anesthetics) the specimes were routinely processed to wax and underwent histological analysis by light microscopy. The histomorfometric analysis showed an increased bone neoformation, increased collagen deposition, less reabsorption and inflammation when laser was associated to the HATCP. It is concluded that IR laser light was able to accelerate fracture healing and the association with HATCP and GBR resulted on increased deposition of CHA.

  20. Peroneal tendon displacement accompanying intra-articular calcaneal fractures.

    PubMed

    Toussaint, Rull James; Lin, Darius; Ehrlichman, Lauren K; Ellington, J Kent; Strasser, Nicholas; Kwon, John Y

    2014-02-19

    Peroneal tendon displacement (subluxation or dislocation) accompanying an intra-articular calcaneal fracture is often undetected and under-treated. The goals of this study were to determine (1) the prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures, (2) the association of tendon displacement with fracture classifications, (3) the association of tendon displacement with heel width, and (4) the rate of missed diagnosis of the tendon displacement on radiographs and computed tomography (CT) scans and the resulting treatment rate. A retrospective radiographic review of all calcaneal fractures presenting at three institutions from June 30, 2006, to June 30, 2011, was performed. CT imaging of 421 intra-articular calcaneal fractures involving the posterior facet was available for review. The prevalence of peroneal tendon displacement was noted and its associations with fracture classification and heel width were evaluated. Peroneal tendon displacement was identified in 118 (28.0%) of the 421 calcaneal fracture cases. The presence of tendon displacement was significantly associated with joint-depression fractures compared with tongue-type fractures (p < 0.001). Only twelve (10.2%) of the 118 cases of peroneal tendon displacement had been identified in the radiology reports. Although sixty-five (55.1%) of the fractures with tendon displacement had been treated with internal fixation, the tendon displacement was treated surgically in only seven (10.8%) of these cases. Analysis of CT images showed a 28% prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures. Surgeons and radiologists are encouraged to consider this association.

  1. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. 888.3320 Section 888.3320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic...

  2. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. 888.3320 Section 888.3320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic...

  3. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. 888.3320 Section 888.3320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic...

  4. Use of resorbable plates and screws in pediatric facial fractures.

    PubMed

    Eppley, Barry L

    2005-03-01

    The use of resorbable plates and screws for fixation of pediatric facial fractures is both well tolerated and effective. It enables realignment and stable positioning of rapidly healing fracture segments while obviating any future issues secondary to long-term metal retention. Forty-four pediatric facial fractures were treated over a 10-year period at our institution using differing techniques of polymeric bone fixation. Twenty-nine mandible fractures in patients under the age of 10 (age range, 6 months to 8 years) were treated. Displaced fractures of the symphysis, parasymphysis, body, and ramus underwent open reduction and either 1.5-mm or 2.0-mm plate and screw fixation in 14 patients. Subcondylar fractures were treated by a short period of maxillomandibular fixation (3 weeks) achieved with suture ligation between resorbable screws placed at the zygoma and symphysis or a circummandibular suture attached to a zygomatic screw. Fifteen patients (age range, 4 to 11 years) with isolated frontal, supraorbital, intraorbital, or orbitozygomatic fractures were treated by open reduction and internal fixation with 1.5-mm resorbable plates, mesh, and screws. No long-term implant-related complications were seen in any of the treated patients. Resorbable polylactic and polyglycolic acid plates and screws can be an effective fixation method for facial fractures in children in the primary and secondary dentition periods.

  5. Fractal Viscous Fingering in Fracture Networks

    NASA Astrophysics Data System (ADS)

    Boyle, E.; Sams, W.; Ferer, M.; Smith, D. H.

    2007-12-01

    We have used two very different physical models and computer codes to study miscible injection of a low- viscosity fluid into a simple fracture network, where it displaces a much-more viscous "defending" fluid through "rock" that is otherwise impermeable. The one code (NETfLow) is a standard pore level model, originally intended to treat laboratory-scale experiments; it assumes negligible mixing of the two fluids. The other code (NFFLOW) was written to treat reservoir-scale engineering problems; It explicitly treats the flow through the fractures and allows for significant mixing of the fluids at the interface. Both codes treat the fractures as parallel plates, of different effective apertures. Results are presented for the composition profiles from both codes. Independent of the degree of fluid-mixing, the profiles from both models have a functional form identical to that for fractal viscous fingering (i.e., diffusion limited aggregation, DLA). The two codes that solve the equations for different models gave similar results; together they suggest that the injection of a low-viscosity fluid into large- scale fracture networks may be much more significantly affected by fractal fingering than previously illustrated.

  6. Before and after hip fracture, vitamin D deficiency may not be treated sufficiently.

    PubMed

    Maier, S; Sidelnikov, E; Dawson-Hughes, B; Egli, A; Theiler, R; Platz, A; Staehelin, H B; Simmen, H-P; Meier, C; Dick, W; Grob, D; von Eckardstein, A; Bischoff-Ferrari, H A

    2013-11-01

    Our findings show that only about 20% of seniors receive vitamin D supplementation prior to their index hip fracture or after the event. We further confirm the high prevalence of severe vitamin D deficiency in this population and show that those who receive supplementation have significantly higher 25-hydroxyvitamin D (25(OH)D) status. The aim of this study is to assess current practice in pre- and post-hip fracture care practice with respect to vitamin D supplementation. We surveyed 1,090 acute hip fracture patients age 65 and older admitted to acute care for hip fracture repair; 844 had serum 25-hydroxyvitamin D levels measured upon admission to acute care, and 362 agreed to be followed at 12 month after their hip fracture. Prevalence of vitamin D supplementation was assessed upon admission to acute care (at the time of hip fracture), upon discharge from acute care, and at 6 and 12 months follow-up. Of 1,090 acute hip fracture patients (mean age 85 years, 78% women, 59 % community-dwelling), 19% had received any dose of vitamin D prior to the index hip fracture, 27% (of 854 assessed) at discharge from acute care, 22 % (of 321 assessed) at 6 month, and 21% (of 285 assessed) at 12 month after their hip fracture. At the time of fracture, 45% had 25(OH)D levels below 10 ng/ml, 81% had levels below 20 ng/ml, and 96% had levels below 30 ng/ml. Notably, 25(OH)D levels did not differ by season or gender but were significantly higher among 164 hip fracture patients, with any vitamin D supplementation compared with 680 without supplementation (19.9 versus 10.8 ng/ml; p < 0.0001). Only about 20% of seniors receive vitamin D at the time of their fracture and after the event. This is despite the documented 81% prevalence of vitamin D deficiency. Interdisciplinary efforts may be warranted to improve vitamin D supplementation in seniors both before a hip fracture occurs and after.

  7. Is transverse acetabular ligament an anatomical landmark to reliably orient the cup in primary total hip arthroplasty?

    PubMed

    Viste, A; Chouteau, J; Testa, R; Chèze, L; Fessy, M-H; Moyen, B

    2011-05-01

    Accurate positioning of the acetabular cup in primary total hip arthroplasty is critical to decrease the rate of dislocation. Inaccurate orientation of the cup is the most common error during this procedure. Target acetabular orientation is still controversial. An original study found a dislocation rate of 0.6% when the cup was aligned with the transverse acetabular ligament (TAL). TAL is a patient-specific anatomical landmark and a tool for cup orientation. Eight cadaveric pelves (14 hips included for study) were harvested in toto at our research laboratory. Anatomical versions of the TAL, labrum and horns were measured in relation to the anterior pelvic plane. A navigator sensor and an optoelectronic device (Motion Analysis™) were used. Anatomical versions of the TAL, horns and labrum averaged 1.9° (range, -8° to +13.3°), 3° (range, -12.2° to 14°), and 26.3° (range, 17.4° to 41.8°), respectively. To our knowledge, this is the first study to report the orientation of the periacetabular soft-tissues. TAL anteversion was outside the safe zone described by Lewinnek, while labrum anteversion was within this safe-zone. We discuss the reference used, Lewinnek's safe zone, and functional orientation of the implants. Lewinnek's safe-zone does not seem to be valid. The TAL seems to be a specific reference for each patient but its reliability must still be confirmed as an adequate reference for positioning the cup in total hip arthroplasty. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  8. Does using a polyethylene RM press-fit cup modify the preparation of the acetabulum and acetabular offset in primary hip arthroplasty?

    PubMed

    Erivan, R; Aubret, S; Villatte, G; Mulliez, A; Descamps, S; Boisgard, S

    2017-09-01

    When performing total hip arthroplasty (THA), it is important to maintain the femoral and acetabular offsets to ensure good joint stability and to restore the function of the hip abductor muscles. In our practice, we mainly use a lateralized stem and hollow out the acetabulum to the quadrilateral plate to accommodate a press-fit polyethylene cup. However, the repercussions of this preparation method, which is driven by the cup's design, are not known. We carried out a retrospective study to assess: (1) the changes in the femoral and acetabular offset; (2) the height of the center of rotation; and (3) the repercussions on wear. We hypothesized there would be no significant differences between the preoperative and postoperative femoral and acetabular offsets. We reviewed 88 primary THA cases performed with the RM Pressfit™ cup that had a minimum of 5 years' follow-up. A lateralized self-locking Muller-type cemented femoral stem was used in 92.0% of cases and a standard stem in 8.0%. Measurements were done on plain radiographs with MHP™ and Mesurim Pro™ software. The average follow-up was 6.5 years (5-8). On average, the acetabular offset was reduced by 2.75mm±5.9 mm (range: -17.5 to +10.6 mm) (P<0.001) and the femoral offset was increased by 0.01mm±5.5 mm (range: -17.8 to +11.0 mm) (P=0.99). In terms of total offset, medialization of 2.74mm±7 mm (range: -17.7 to +18.2mm) was found (P=0.001). The acetabular center of rotation was on average 4.77mm±5.1 mm higher (P<0.001). The mean annual wear at the more recent follow-up (min.: 5 years) was 0.068mm (range: 0.01 to 0.25mm) per year. The wear was not impacted by having more than 5mm change in offset. Measurements of acetabular offset revealed statistically significant medialization due to the type of implant used and the surgical technique. The anatomical technique consists of positioning the cup in subchondral bone without contacting the quadrilateral plate. This preserves bone stock, which may be

  9. Intrinsic mechanical behavior of femoral cortical bone in young, osteoporotic and bisphosphonate-treated individuals in low- and high energy fracture conditions

    DOE PAGES

    Zimmermann, Elizabeth A.; Schaible, Eric; Gludovatz, Bernd; ...

    2016-02-16

    Bisphosphonates are a common treatment to reduce osteoporotic fractures. This treatment induces osseous structural and compositional changes accompanied by positive effects on osteoblasts and osteocytes. Here, we test the hypothesis that restored osseous cell behavior, which resembles characteristics of younger, healthy cortical bone, leads to improved bone quality. Microarchitecture and mechanical properties of young, treatment-naïve osteoporosis, and bisphosphonate-treated cases were investigated in femoral cortices. Tissue strength was measured using three-point bending. Collagen fibril-level deformation was assessed in non-traumatic and traumatic fracture states using synchrotron small-angle x-ray scattering (SAXS) at low and high strain rates. The lower modulus, strength and fibrilmore » deformation measured at low strain rates reflects susceptibility for osteoporotic low-energy fragility fractures. Independent of age, disease and treatment status, SAXS revealed reduced fibril plasticity at high strain rates, characteristic of traumatic fracture. We find the significantly reduced mechanical integrity in osteoporosis may originate from porosity and alterations to the intra/extrafibrillar structure, while the fibril deformation under treatment indicates improved nano-scale characteristics. In conclusion, losses in strength and fibril deformation at low strain rates correlate with the occurrence of fragility fractures in osteoporosis, while improvements in structural and mechanical properties following bisphosphonate treatment may foster resistance to fracture during physiological strain rates.« less

  10. Intrinsic mechanical behavior of femoral cortical bone in young, osteoporotic and bisphosphonate-treated individuals in low- and high energy fracture conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zimmermann, Elizabeth A.; Schaible, Eric; Gludovatz, Bernd

    Bisphosphonates are a common treatment to reduce osteoporotic fractures. This treatment induces osseous structural and compositional changes accompanied by positive effects on osteoblasts and osteocytes. Here, we test the hypothesis that restored osseous cell behavior, which resembles characteristics of younger, healthy cortical bone, leads to improved bone quality. Microarchitecture and mechanical properties of young, treatment-naïve osteoporosis, and bisphosphonate-treated cases were investigated in femoral cortices. Tissue strength was measured using three-point bending. Collagen fibril-level deformation was assessed in non-traumatic and traumatic fracture states using synchrotron small-angle x-ray scattering (SAXS) at low and high strain rates. The lower modulus, strength and fibrilmore » deformation measured at low strain rates reflects susceptibility for osteoporotic low-energy fragility fractures. Independent of age, disease and treatment status, SAXS revealed reduced fibril plasticity at high strain rates, characteristic of traumatic fracture. We find the significantly reduced mechanical integrity in osteoporosis may originate from porosity and alterations to the intra/extrafibrillar structure, while the fibril deformation under treatment indicates improved nano-scale characteristics. In conclusion, losses in strength and fibril deformation at low strain rates correlate with the occurrence of fragility fractures in osteoporosis, while improvements in structural and mechanical properties following bisphosphonate treatment may foster resistance to fracture during physiological strain rates.« less

  11. [Four cases of penile fracture].

    PubMed

    Ohtake, Shinji; Nakaigawa, Noboru; Kubota, Yoshinobu

    2013-04-01

    Penile fracture is not common but is an emergency disease. We report 4 cases of penile fracture treated at the Department of Urology, Yokohama City University between 2005 and 2012. The age of the patients ranged between 26 and 67 years (mean age, 41.5 years). Of the patients in our series, 3 sustained injury during sexual intercourse, and 1 while rolling over in bed. All patients were treated surgically and cured without any functional disturbance after treatment. Reports before 2002 and 99 cases after 2002 were also reviewed. The number of patients between 40 and 60 years was increasing. Magnetic resonance imaging was useful to detect the site of penile fracture and immediate surgical treatment was important.

  12. A hierarchy of computationally derived surgical and patient influences on metal on metal press-fit acetabular cup failure.

    PubMed

    Clarke, S G; Phillips, A T M; Bull, A M J; Cobb, J P

    2012-06-01

    The impact of anatomical variation and surgical error on excessive wear and loosening of the acetabular component of large diameter metal-on-metal hip arthroplasties was measured using a multi-factorial analysis through 112 different simulations. Each surgical scenario was subject to eight different daily loading activities using finite element analysis. Excessive wear appears to be predominantly dependent on cup orientation, with inclination error having a higher influence than version error, according to the study findings. Acetabular cup loosening, as inferred from initial implant stability, appears to depend predominantly on factors concerning the area of cup-bone contact, specifically the level of cup seating achieved and the individual patient's anatomy. The extent of press fit obtained at time of surgery did not appear to influence either mechanism of failure in this study. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Omnidirectional Internal Fixation by Double Approaches for Treating Rüedi-Allgöwer Type III Pilon Fractures.

    PubMed

    Dai, Chong-Hua; Sun, Jun; Chen, Kun-Quan; Zhang, Hui-Bo

    In the present study, we explored the effectiveness and complications of omnidirectional internal fixation using a double approach for treating Rüedi-Allgöwer type III pilon fractures. A retrospective analysis was performed of 19 cases of Rüedi-Allgöwer type III unilateral closed pilon fracture. With preoperative preparation and correct surgical timing, the reduction was performed using anteromedial and posterolateral approaches, and the fracture fragments were fixed by omnidirectional internal fixation. Imaging evaluation was performed using the Burwell-Charnley scoring system. The Johner-Wruhs scoring system was used to assess the functional status of the patients. A comprehensive evaluation of efficacy was performed using a 5-point Likert score. The complications were also recorded and analyzed. All patients were followed up for an average of 16.2 months. The operative incisions of 15 cases healed by primary intent and with delayed healing in 4. All patients had achieved bony union at an average of 16 weeks postoperatively. No deep infection, broken nail or withdrawn nail, exposed plate, or skin flap necrosis occurred. The Burwell-Charnley imaging evaluation showed that 14 patients had anatomic reduction of the articular surface and 5 had acceptable reduction. Using the Johner-Wruhs scoring system, the results were excellent for 8, good for 7, fair for 2, and poor for 2 patients; the combined rate of excellent and good results was 78.9%. The Likert score of efficacy self-reported by the patients was 3 to 4 points for 12 patients, 2 points for 4 patients, and 0 to 1 point for 3 patients. The Likert score of therapeutic efficacy reported by the physicians was 3 to 4 points for 10 patients, 2 points for 5 patients, and 0 to 1 point for 4 patients. Omnidirectional internal fixation using double approaches was an effective method to treat Rüedi-Allgöwer type III pilon fractures with satisfactory reduction and rigid fixation, good joint function recovery, and

  14. Post-fracture management of patients with hip fracture: a perspective.

    PubMed

    Bruyere, O; Brandi, M-L; Burlet, N; Harvey, N; Lyritis, G; Minne, H; Boonen, S; Reginster, J-Y; Rizzoli, R; Akesson, K

    2008-10-01

    Hip fracture creates a worldwide morbidity, mortality and economic burden. After surgery, many patients experience long-term disability or die as a consequence of the fracture. A fracture is a major risk factor for a subsequent fracture, which may occur within a short interval. A literature search on post-fracture management of patients with hip fracture was performed on the Medline database. Key experts convened to develop a consensus document. Management of hip-fracture patients to optimize outcome after hospital discharge requires several stages of care co-ordinated by a multidisciplinary team from before admission through to discharge. Further studies that specifically assess prevention and post-fracture management of hip fracture are needed, as only one study to date has assessed an osteoporosis medication in patients with a recent hip fracture. Proper nutrition is vital to assist bone repair and prevent further falls, particularly in malnourished patients. Vitamin D, calcium and protein supplementation is associated with an increase in hip BMD and reduction in falls. Rehabilitation is essential to improve functional disabilities and survival rates. Fall prevention and functional recovery strategies should include patient education and training to improve balance and increase muscle strength and mobility. Appropriate management can prevent further fractures and it is critical that high-risk patients are identified and treated. To foster this process, clinical pathways have been established to support orthopaedic surgeons. Although hip fracture is generally associated with poor outcomes, appropriate management can ensure optimal recovery and survival, and should be prioritized after a hip fracture to avoid deterioration of health and prevent subsequent fracture.

  15. Fracture heuristics: surgical decision for approaches to distal radius fractures. A surgeon's perspective.

    PubMed

    Wichlas, Florian; Tsitsilonis, Serafim; Kopf, Sebastian; Krapohl, Björn Dirk; Manegold, Sebastian

    2017-01-01

    Introduction: The aim of the present study is to develop a heuristic that could replace the surgeon's analysis for the decision on the operative approach of distal radius fractures based on simple fracture characteristics. Patients and methods: Five hundred distal radius fractures operated between 2011 and 2014 were analyzed for the surgeon's decision on the approach used. The 500 distal radius fractures were treated with open reduction and internal fixation through palmar, dorsal, and dorsopalmar approaches with 2.4 mm locking plates or underwent percutaneous fixation. The parameters that should replace the surgeon's analysis were the fractured palmar cortex, and the frontal and the sagittal split of the articular surface of the distal radius. Results: The palmar approach was used for 422 (84.4%) fractures, the dorsal approach for 39 (7.8%), and the combined dorsopalmar approach for 30 (6.0%). Nine (1.8%) fractures were treated percutaneously. The correlation between the fractured palmar cortex and the used palmar approach was moderate (r=0.464; p<0.0001). The correlation between the frontal split and the dorsal approach, including the dorsopalmar approach, was strong (r=0.715; p<0.0001). The sagittal split had only a weak correlation for the dorsal and dorsopalmar approach (r=0.300; p<0.0001). Discussion: The study shows that the surgical decision on the preferred approach is dictated through two simple factors, even in the case of complex fractures. Conclusion: When the palmar cortex is displaced in distal radius fractures, a palmar approach should be used. When there is a displaced frontal split of the articular surface, a dorsal approach should be used. When both are present, a dorsopalmar approach should be used. These two simple parameters could replace the surgeon's analysis for the surgical approach.

  16. [Early application of the antibiotic-laden bone cement (ALBC) combined with the external fixation support in treating the open fractures of lower limbs complicated with bone defect].

    PubMed

    Xiao, Jian; Mao, Zhao-Guang; Zhu, Hui-Hua; Guo, Liang

    2017-03-25

    To discuss the curative effect of the early application of the antibiotic-laden bone cement (ALBC) combined with the external fixation support in treating the open fractures of lower limbs complicated with bone defect. From December 2013 to January 2015, 36 cases of lower limb open comminuted fractures complicated with bone defects were treated by the vancomycin ALBC combined with the external fixation support, including 26 males and 10 females with an average age of 38.0 years old ranging from 19 to 65 years old. The included cases were all open fractures of lower limbs complicated with bone defects with different degree of soft tissue injuries. Among them, 25 cases were tibial fractures, 11 cases were femoral fractures. The radiographs indicated a presence of bone defects, which ranged from 3.0 to 6.1 cm with an average of 4.0 cm. The Gustilo classification of open fractures:24 cases were type IIIA, 12 cases were typr IIIB. The percentage of wound infection, bone grafting time, fracture healing time and postoperative joint function of lower limb were observed. The function of injured limbs was evaluated at 1 month after the clinical healing of fracture based on Paley evaluation criterion. All cases were followed up for 3 to 24 months with an average of (6.0±3.0) months. The wound surface was healed well, neither bone infections nor unhealed bone defects were presented. The reoperation of bone grafting was done at 6 weeks after the patients received an early treatment with ALBC, some of them were postponed to 8 weeks till the approximate healing of fractures, the treatment course lasted for 4 to 8 months with an average of(5.5±1.5) months. According to Paley and other grading evaluations of bone and function, there were 27 cases as excellent, 5 cases as good, 3 cases as ordinary. The ALBC combined with external fixation support was an effective method for early treatment to treat the traumatic lower limb open fractures complicated with bone defects. This method

  17. Treatment of the femoral shaft fracture with a curved heat-treated COP clover-leaf nail.

    PubMed

    Onoue, Y; Sunami, Y; Fujiwara, H; Sadakane, T; Yasuda, S

    1979-01-01

    The commonly used straight intramedullary nail has certain limitations and disadvantages. Following radiographic and metallurgical studies we have developed a curved heat-treated clover-leaf nail using a newly developed precipitation hardening stainless steel (COP). The nail is bent with a slot on the convex side and the radius of curvature is 115 cm which corresponds to the anatomical antero-lateral convexity of the human femur. The nail has been satisfactory in clinical use since 1971 and has provided not only more stable internal fixation but also allowed fixation of fractures beyond the middle third of the shaft.

  18. Radiologic Changes by Early Motion in Neck Fractures of the Fifth Metacarpal Treated with Antegrade Intramedullary Fixation.

    PubMed

    Heo, Youn Moo; Kim, Sang Bum; Yi, Jin Woong; Kim, Tae Gyun; Lim, Byoung Gu

    2016-02-01

    As intramedullary (IM) fixation is one of the fixation methods used in neck fractures of the fifth metacarpal, an early motion of injured finger can be allowed. The purpose of this study is to evaluate whether immediate active motion affects the stability of antegrade IM fixation in surgical treatment of neck fractures of the fifth metacarpal bone and to assess related factors. Thirty one patients treated by closed reduction and antegrade IM fixation were consecutively enrolled. All patients started active motion of the little finger since 7 postoperative days and only daily activities including writing, typing or washing were allowed until the union of fracture. All fractures were healed within four to eight weeks. The changes of angulation, fifth metacarpal length and tip to head distance of K-wire were compared between immediate postoperative radiographs and radiographs at eight weeks. In addition, the effects by age, gender, initial angulation and comminution of the metacarpal neck were assessed. The average change of angulation was 0.12°, 5th metacarpal length was 1.49mm and tip to head distance of K-wire was 1.31mm. There was no significant difference in the change of angulation (p = 0.137). But, there were significant differences in the change of 5th metacarpal length and tip to head distance of K-wire ([Formula: see text]). The change of angulation was related to a comminution of the metacarpal neck and that of 5th metacarpal length was related to age and sex. The change of 5th metacarpal length and tip to head distance of K-wire can occur by an early mobilization in the antegrade IM fixation for neck fractures of the fifth metacarpal. However, we thought that an early active motion after surgery is important to increase the patients' satisfaction, even though careful selection of candidates is necessary.

  19. Avascular Necrosis of Acetabulum: The Hidden Culprit of Resistant Deep Wound Infection and Failed Fixation of Fracture Acetabulum - A Case Report.

    PubMed

    K, Kandhari V; M, Desai M; S, Bava S; N, Wade R

    2015-01-01

    Chances of avascular necrosis of acetabulum are rare as it enjoys a rich blood supply. But cases of post - traumatic avascular necrosis of acetabulum following fracture of posterior column have been well documented. Importance of identifying and suspecting the avascular necrosis of acetabulum is essential in cases of failed fixation of fracture acetabulum, previously operated using extensile approach to acetabulum; either extended anterior ilio - femoral or tri - radiate approach. Such patients usually present with repeated deep bone infection or with early failure of fixation with aseptic loosening and migration of its components. We present a similar case. 40 years female presented with inadequately managed transverse fracture of left acetabulum done by anterior extended ilio-inguinal approach. The fixation failed. She presented 6 months later with painful hip. Cemented total hip replacement was performed with reconstruction of acetabulum by posterior column plating. Six months postoperatively patient presented with dislodgement of cup, pelvic discontinuity and sinus in the thigh. Two stage revision surgery was planned. First implant, removal; debridement and antibiotic spacer surgery was performed. At second stage of revision total hip replacement, patient had Paprosky grade IIIb defect in acetabulum. Spacer was removed through the posterior approach. Anterior approach was taken for anterior plating. Intra-operatively external iliac pulsations were found to be absent so procedure was abandoned after expert opinion. Postoperatively digital subtraction angiography demonstrated a chronic block in the external iliac artery and corona mortis was the only patent vascular channel providing vascular to the left lower limb. Thus, peripheral limb was stealing blood supply from the acetabulum to maintain perfusion. Patient was ultimately left with pelvic discontinuity, excision arthroplasty and pseudoarthrosis of the left hip. Avascular necrosis of acetabulum is a rare

  20. [Comparing clinical effects of titanic elastic nail and locking compression pine fixation in treating subtrochanteric fractures in older children].

    PubMed

    Zhu, Kang-xiang; Yin, Shan-qing

    2013-12-01

    To explore optimal choice of surgical treatment for subtrochanteric fractures in older children. A retrospective study of 36 older children with subtrochanteric fractures was performed between January 2010 and January 2012. Among them, 18 patients (11 males and 7 females) aged from 7 to 13 years old with an average of 9.4 were treated with titanic elastic nail (TEN) fixation, 4 cases were Type II A, 3 cases were II B, 2 cases were II C, 4 cases were III A, 3 cases were III B according to Seinsheimer classification. Eighteen patients (10 males and 8 females) aged was from 8 to 13 years with an average of 9.6 were treated with locking compression pine (LCP) fixation, and 3 cases were Type II A, 4 cases were II B, 3 cases were II C, 4 cases were IIIA, 2 cases were III B. Fracture healing time, postoperative complications (including wound infection, failure and breakage of internal fixtion, deformities of angular on the sagittal view, deformities of coxa vara) and recovery of hip joint function were observed and recorded. All children were followed up from 15 to 36 months with an average of 21. Fracture were all healed, the time ranged from 7 to 16 weeks (mean 9.5). Three cases in TEN group occurred mild deformities of angular on the sagittal view, 3 cases occurred deformities of coxa vara and 2 cases occurred limb shortening; while 1 case occurred mild deformities of angular on the sagittal view, and no deformities of coxa vara and limb shortening occurred in LCP group. No early close of epiphyseal injury, avascular necrosis of femoral head occurred. Clinical efficacy were evaluated by Sanders standard, 14 cases got excellent results, 3 cases were moderate in LCP group, while 9 cases in excellent, 4 in moderate in TEN group. There were no significant differences between two group in recovery of hip joint function and complications. For the treatment of subtrochanteric fractures in older children,the efficacy of LCP fixation is better than that of TFN fixation, which

  1. Assessment of the influence of Laser phototherapy on the bone repair process of complete fractures in tibiae of rabbits stabilized with semi-rigid internal fixation treated with or without MTA graft: a histological study

    NASA Astrophysics Data System (ADS)

    Soares, Luiz G. P.; Silva, Aline C. P.; Silva, Anna Paula L. T.; Neves, Bruno Luiz R. C.; Santos, Nicole R. S.; dos Santos, Jean N.; Pinheiro, Antonio L. B.

    2016-03-01

    Beside biomaterials, Laser phototherapy has shown positive effects as auxiliary therapy in bone repair process, especially when involving large bone losses. The aim of this histological study was to evaluate, by light microscopy, the influence of laser phototherapy on the repair of complete tibial fractures in rabbits treated or not with semi-rigid internal fixation and Mineral Trioxide Aggregate - MTA graft. Twelve Rabbits were randomly divided into four groups with three animals each. After general anesthesia, complete fractures were created in one tibia with a carborundum disk. All animals (groups I-IV) had the fracture stabilized with semi-rigid fixation (wire osteosynthesis - WO). Group I was routinely fixed with WO; groups II and IV fracture was filled by blood clot and MTA implant. In Groups III and IV fracture was filled by blood clot and further irradiated with laser (λ780 nm, 70 mW, CW, Φ = 0.04 cm2, 20.4 J/cm2, per session, t = 300s, 142.8 J/cm2 per treatment). The phototherapy protocol was applied immediately after the surgery and repeated each 48 hours during 15 days. Animal death occurred on the 30th postoperative day. After removal of the specimens, the samples were routinely processed, stained with HE and evaluated by light microscopy. Histologically, the group treated with MTA graft and irradiated with laser showed the fracture filled by a more organized and mature trabecular bone, when compared with all other groups. From the results of the present study, it may be concluded that the association of Laser phototherapy + MTA graft in fractures treated with WO improved bone repair when compared with fractures treated only with WO.

  2. A novel computer algorithm for modeling and treating mandibular fractures: A pilot study.

    PubMed

    Rizzi, Christopher J; Ortlip, Timothy; Greywoode, Jewel D; Vakharia, Kavita T; Vakharia, Kalpesh T

    2017-02-01

    To describe a novel computer algorithm that can model mandibular fracture repair. To evaluate the algorithm as a tool to model mandibular fracture reduction and hardware selection. Retrospective pilot study combined with cross-sectional survey. A computer algorithm utilizing Aquarius Net (TeraRecon, Inc, Foster City, CA) and Adobe Photoshop CS6 (Adobe Systems, Inc, San Jose, CA) was developed to model mandibular fracture repair. Ten different fracture patterns were selected from nine patients who had already undergone mandibular fracture repair. The preoperative computed tomography (CT) images were processed with the computer algorithm to create virtual images that matched the actual postoperative three-dimensional CT images. A survey comparing the true postoperative image with the virtual postoperative images was created and administered to otolaryngology resident and attending physicians. They were asked to rate on a scale from 0 to 10 (0 = completely different; 10 = identical) the similarity between the two images in terms of the fracture reduction and fixation hardware. Ten mandible fracture cases were analyzed and processed. There were 15 survey respondents. The mean score for overall similarity between the images was 8.41 ± 0.91; the mean score for similarity of fracture reduction was 8.61 ± 0.98; and the mean score for hardware appearance was 8.27 ± 0.97. There were no significant differences between attending and resident responses. There were no significant differences based on fracture location. This computer algorithm can accurately model mandibular fracture repair. Images created by the algorithm are highly similar to true postoperative images. The algorithm can potentially assist a surgeon planning mandibular fracture repair. 4. Laryngoscope, 2016 127:331-336, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  3. [Functional and radiological evaluation of patients with midshaft clavicle fracture surgically treated].

    PubMed

    Ojeda-Reyes, Ángel Jesús; Barragán-Hervella, Rodolfo Gregorio; Vallecillo-Velázquez, Hernán; Alvarado-Ortega, Iván; Romero-Figueroa, María Socorro; Montiel-Jarquín, Álvaro José

    2016-01-01

    Functional and radiographic evaluation at midshaft clavicle fractures is better with surgical than conservative management. The aim of this paper is to describe the functional and radiological evaluation of patients with midshaft clavicle fracture surgery at the Hospital de Traumatología y Ortopedia of the Instituto Mexicano del Seguro Social. Descriptive studies, conducted during the period June 2014 to June 2015, patients undergoing surgical treatment for midshaft clavicle fracture were included. Constant-Murley and Montoya Scales were used to evaluate the functionality and radiological consolidation 6 months after the treatment. There were 90 patients, average age was 33.63 years, 78.9% were men, left side affected in 53.3% patients. At 6 months after surgery, functional results were excellent in 87.8% of patients, in 91% there was disappearance of fracture line regardless callus. The group of patients aged 18 and 40 years present better functional and radiographic results compared to the other groups (p <0.05). The management of patients with diaphyseal clavicle fracture should be surgical, ages between 18 to 40 years and between 61 to 76 years have better functional outcomes with greater consolidation of fracture line regardless of the callus.

  4. [Pathologic proximal femoral fractures in children in an unicameral bone cyst].

    PubMed

    Havránek, P; Pesl, T; Bartonícek, J

    2005-01-01

    Proximal femoral fractures in children are rare, pathologic fractures being extremely rare. Despite many meanings these fractures are still "unsolved" there are some definite rules for treatment of true accidental injuries. Pathologic fractures are outstanding with their extremely rare incidence. The aim of the study is to overview a large clinical material, find out the incidence of this pathologic fracture, the extent and shape of the unicameral bone cyst (UBC), specific therapeutic approach, technical problems of eventual osteosynthesis, number of reoperations and sequels. Altogether 49 children with 50 accidental and pathologic fractures of proximal part of the femur treated in the Regional Pediatric Trauma Centre of the Department of Pediatric and Trauma Surgery, 3rd Faculty of Medicine, Charles University, Prague. Retrospective and prospective study of children (0 to 15 years of age) treated with proximal femoral accidental and pathologic fractures during the 20 year period (from August 1984 to November 2004). Classification of fractures according to Delbet and Colonna. Diagnosis of bone cyst with plain X-rays, eventually CT scans. During the 20 years period (August 1984 to November 2004) 49 children with 50 proximal femoral fractures were treated in the Department. Four patients sustained a pathologic fracture through an unicameral bone cyst. Two of these latter children were treated by an open reduction and osteosynthesis with the use of the proximal femoral AO-ASIF angled-plate and two children nonoperatively using skeletal traction because of impossibility of insertion of the osteosynthetic material without a damage of the growth plate. Subsequent operations of the UBC were necessary in these two children. All four patients recovered well without sequels. Pathologic fractures in UBC are usually treated nonoperatively and the cyst itself is treated after fracture healing. Proximal femoral impairment is the exception from this rule because of weigh bearing

  5. Pediatric mandibular fractures.

    PubMed

    Thaller, S R; Mabourakh, S

    1991-06-01

    In spite of curiosity, facial fractures, particularly mandibular fractures, in the pediatric age group embrace only a modest proportion of facial fractures that occur within the general population. Several large series report an overall incidence of approximately 1% of all facial bone fractures. A considerable volume of literature has been generated describing the pattern of injury and treatment modalities for pediatric facial bone fractures. At our institution, which is an extremely busy university-based regional trauma center, we have witnessed a persistent escalation in the number of patients requiring repair of their facial bone fractures. During the period of January 1989 through January 1990, we treated a total of 204 patients for repair of mandible fractures. An analysis of the records of this group revealed only 3 patients who were younger than 4 years of age and 2 additional patients younger than 8 years. There were another 10 patients 17 years and younger, for a total incidence of 0.08%. Additionally, we found that within this seemingly small group, there was a surprisingly high incidence of severe, associated injuries.

  6. Comminuted inferior pole fracture of patella can be successfully treated with rim-plate-augmented separate vertical wiring.

    PubMed

    Cho, Jae-Woo; Kim, Jinil; Cho, Won-Tae; Gujjar, Pranay H; Oh, Chang-Wug; Oh, Jong-Keon

    2018-02-01

    We present the surgical technique of rim-plate-augmented separate vertical wiring for comminuted inferior pole fracture of the patella and report the clinical outcomes. Between July 2013 and January 2016, 13 patients (7 male and 6 female) who were diagnosed with comminuted inferior pole fracture of the patella in preoperative computed tomography and underwent a minimum of 1 year of follow-up were enrolled in this study. Mean patient age was 57.7 years (range 28-72 years). All patients underwent open reduction and internal fixation by rim-plate-augmented separate vertical wiring. Bony union, complications, range of motion and Bostman score were the clinical outcomes. Bony union was achieved in all cases at an average of 10 weeks after surgery (range 8-12). There was no loss of reduction and fixative failure during follow-up. The average range of motion was 127° (range 120°-130°). The mean Bostman score at last follow-up was 29.6 points (range 27-30) and graded excellent in 12 patients. Rim-plate-augmented separate vertical wiring demonstrated secure fixation and favorable clinical outcomes. This study provides evidence for its effectiveness as a fixation method for treating displaced, comminuted inferior pole fracture of the patella.

  7. The reinforcement effect of polyethylene fibre and composite impregnated glass fibre on fracture resistance of endodontically treated teeth: An in vitro study

    PubMed Central

    Luthria, Archana; Srirekha, A; Hegde, Jayshree; Karale, Rupali; Tyagi, Sanjana; Bhaskaran, Sajeev

    2012-01-01

    Aim: The aim of this study was to evaluate the fracture resistance of endodontically treated maxillary premolars with wide mesio-occluso-distal (MOD) cavities restored with either composite resin, or composite resin reinforced with different types of fibres. Materials and Methods: Fifty human maxillary premolars were selected. Five intact teeth served as positive controls. Endodontic therapy was carried out in the remaining forty-five teeth. Standardized MOD cavities were prepared in all the teeth. The teeth were restored with a nanocomposite using an incremental technique. These forty five teeth were randomly divided into three experimental groups (Group A, B and C) (n = 15). The teeth in Group A did not undergo any further procedures. The teeth in Group B and C were reinforced with composite impregnated glass fibre and polyethylene fibre, respectively. Fracture resistance was measured in Newtons (N). Results: The positive controls showed the highest mean fracture resistance (811.90 N), followed by Group B (600.49N), Group A (516.96N) and Group C (514.64N), respectively. One Way analysis of variance (ANOVA) test revealed a statistically significant difference between all the groups (P = 0.001). Post-hoc Tukey test revealed a moderately significant difference (P = 0.034) between Control and Group B, and a strongly significant difference between Control and Group A (P = 0.002), and Control and Group C (P = 0.001). Conclusions: Endodontic therapy and MOD cavity preparation significantly reduced the fracture resistance of endodontically treated maxillary premolars (P = 0.001). No statistically significant difference was found between the experimental groups (Group A, B and C) (P > 0.1). However, the fracture resistance of the composite impregnated glass fibre reinforced group was much higher than the others. PMID:23112487

  8. [Conservative treatment of metacarpal fracture].

    PubMed

    Prokop, A; Helling, H J; Kulus, S; Rehm, K E

    2002-01-01

    Conservative treatment of meatacarpale fracture is recommended if there are no joint displacement, rotation failures, displacement over 30 degrees ad axim and shortening over 5 mm. Operative procedures should be done in open fractures and serial of fractures of metacarpale bones. Early functionally treatment should be done in stable, not displaced fractures. Cast can be used only for a short time in full extended position of fingers and flexion in metacarpo-phalangeal joint in 60-90 degrees. Twin-tapes after reduction of edema allowed free range of motion by fixed rotation. Closed reduction of displaced fractures of fifth metacarpal bone (boxer's fracture) isn't successful. Cases with displacement over 30 degrees may be operatively treated by intramedullary stabilization.

  9. Factors Associated With Narcotic Use After Clavicle Fractures.

    PubMed

    Weinberg, Douglas S; Napora, Joshua K; West, William H; Grimberg, Dominic C; Vallier, Heather A

    2016-09-01

    Clavicle fractures are common in adults. Recent studies have shown that operative treatment of clavicle fractures has benefits in many situations. However, there is controversy about the indications. Data on social outcomes are limited. A total of 434 patients with 436 clavicle fractures treated both operatively and nonoperatively at a level 1 trauma center were identified. Narcotic use was recorded 2, 4, 6, 8, 10, 12, 14, and 16 weeks after injury for both treatment groups. Other descriptive data included age, sex, laterality, hand dominance, rib fractures, smoking, alcohol use, employment, long bone or spine fracture, open clavicle fracture, and mechanism of injury. Logistic regression analysis was performed to determine the independent predictors of narcotic use after clavicle fracture. Open reduction and internal fixation was performed in 105 fractures (24%), and 329 fractures were managed nonoperatively. A total of 154 patients (35%) reported some narcotic use 2 weeks after injury, and 15% were still using narcotics 16 weeks after injury. Narcotic use decreased over time in patients treated with open reduction and internal fixation (10% vs 15% after nonoperative management). Patients treated with open reduction and internal fixation reported reduced narcotic use at 16 weeks (odds ratio [OR], 0.454; P=.070). Concurrent rib fracture (OR, 5.668; P<.001), smoking (OR, 3.095; P=.013), unemployment (OR, 5.429; P<.0005), and long bone or spine fracture (OR, 6.761; P<.001) were predictors of narcotic use. Further studies of the social, economic, and financial outcomes of clavicle fracture and osteosynthesis are warranted. [Orthopedics. 2016; 39(5):e917-e923.]. Copyright 2016, SLACK Incorporated.

  10. Pregnancy-associated osteoporosis with eight fractures in the vertebral column treated with kyphoplasty and bracing: a case report.

    PubMed

    Bonacker, J; Janousek, M; Kröber, M

    2014-02-01

    Pregnancy-associated osteoporosis is a rare condition, which imposes multiple symptoms in the musculoskeletal system. Common complaints announced by patients are severe pain in the lower back, hips and the joints of the lower extremities with a reduced and less mobility status in general. Most of the patients' problems occur in the last trimester of pregnancy or postpartum and are often not diagnosed as side effects of osteoporosis but as problems associated with pregnancy. Although vertebral fractures are rare complications of pregnancy-associated osteoporosis, they should be always considered in women presenting with an acute pain syndrome in peripregnancy period. This case presents a 40-year-old primagravid woman who developed pain in hips and severe pain in the lower back causing an immobilization diagnosed with a pregnancy-associated osteoporosis with eight compression fractures in the thoracic and lumbar spine. Because of sagittal imbalance of the spine, she was treated with kyphoplasty at the four lumbar fractures and with bracing for the upper, thoracic ones, additional to the conservative anti-osteoporotic therapy. The authors discuss pregnancy-associated osteoporosis and its clinical presentation, as well as the indications of kyphoplasty, spinal alignment and the risk of single conservative treatment.

  11. Outcome of distal end clavicle fractures treated with locking plates.

    PubMed

    Vaishya, Raju; Vijay, Vipul; Khanna, Vikram

    2017-02-01

    Fractures of the lateral end of the clavicle are relatively uncommon. These fractures are unstable due to the various deforming forces which act on the fragments as well as the small distal fracture fragment. At most times the deforming forces are not taken into consideration, and the fracture is not fixed securely. In this study, we assessed a fixation technique using the precontoured locking plates to find out whether it provided a stable fixation with good functional outcome. Totally, 32 patients with lateral end clavicle fracture (Neer's Type II) were included in the study. After the informed consent and preoperative investigations were obtained, open reduction and internal fixation was done using a 3.5 mm precontoured superior locking plate with lateral extension under general anesthesia. Postoperative X-rays were done on day 1 and every 6 weeks after operation, until radiological union was achieved. The postoperative pain was assessed using Visual Analogue Scale (VAS) on postoperative days 1, 2 and 10. Postoperatively arm pouch sling was given for 2 weeks followed by active mobilization. Patients were asked to do their daily routine work and avoid lifting heavy weights. The functional outcome was assessed at the end of 2nd and 6th months with the help of Disabilities of the Arm, Shoulder and Hand (DASH) scoring. There were no intraoperative complications in the procedure. The mean VAS score on postoperative day 1 was found to be 5 which decreased to 3 on day 2 and 0 on day 10. The mean DASH score was calculated as 11.63 at the end of postoperative month 2 and then 4.6 at the end of month 6. There was one case of malunion in whom the overhead abduction was restricted but was not painful and was managed conservatively. The precontoured locking plates with lateral extension may be a good method to fix the fractures of the lateral end clavicle, which provide a stable fixation with good functional outcome with very few instances of stiffness and decreased range

  12. Radial and tibial fracture repair with external skeletal fixation. Effects of fracture type, reduction, and complications on healing.

    PubMed

    Johnson, A L; Kneller, S K; Weigel, R M

    1989-01-01

    Twenty-eight consecutive fractures of the canine radius and tibia were treated with external skeletal fixation as the primary method of stabilization. The time of fixation removal (T1) and the time to unsupported weight-bearing (T2) were correlated with: (1) bone involved; (2) communication of the fracture with the external environment; (3) severity of the fracture; (4) proximity of the fracture to the nutrient artery; (5) method of reduction; (6) diaphyseal displacement after reduction; and (7) gap between cortical fragments after reduction. The Kruskal-Wallis one-way analysis of variance was used to test the correlation with p less than .05 set as the criterion for significance. The median T1 was 10 weeks and the median T2 was 11 weeks. None of the variables correlated significantly with either of the healing times; however, there was a strong trend toward longer healing times associated with open fractures and shorter healing times associated with closed reduction. Periosteal and endosteal callus uniting the fragments were observed radiographically in comminuted fractures, with primary bone union observed in six fractures in which anatomic reduction was achieved. Complications observed in the treatment of these fractures included: bone lysis around pins (27 fractures), pin track drainage (27 fractures), pin track hemorrhage (1 fracture), periosteal reaction around pins (27 fractures), radiographic signs consistent with osteomyelitis (12 fractures), degenerative joint disease (2 dogs), and nonunion (1 fracture). Valgus or rotational malalignment resulted in 16 malunions of fractures. One external fixation device was replaced and four loose pins were removed before the fractures healed. One dog was treated with antibiotics during the postoperative period because clinical signs of osteomyelitis appeared.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Fracture penis: an analysis of 26 cases.

    PubMed

    Pandyan, G V Soundra; Zaharani, Ahmed Bakeet; Al Rashid, Mohammed

    2006-01-29

    The aim of this study was to review the pattern of penile fracture occurrence, its clinical presentation, diagnosis, management, and outcome at our center. A retrospective analysis of 26 patients with penile fractures treated at our hospital from January 1997 to January 2005 was carried out. We noted an incidence of 3.5 cases per year, occurring more commonly in unmarried men. Of our study group, 28 episodes of penile fractures occurred in 26 patients. Hospital presentation after trauma varied from 2 h to 21 days. Masturbation was the main initiating causative factor and penile hematoma was the most common clinical finding. Nearly 81% noticed the characteristic click prior to the fracture. Clinical diagnosis was adequate in a majority of the cases. Midshaft fractures with right-sided laterality were more frequent in this series. The tear size ranged from 0.5-2.5 cm with a mean of 1.1 cm. All cases, but one, were treated by surgical repair using absorbable sutures. Out of three cases treated conservatively, two failed to respond and had to be treated surgically. False fracture with dorsal vein tear was present in two cases. Involvement of bilateral corpora was seen in one patient. Infection was the most common early complication, while pain with deviation was the late complication. In our experience, clinical findings are adequate enough to diagnose fracture penis in a majority of cases. Surgical exploration with repair of the tear is recommended both in early and delayed presentations. There was no noticeable relationship to the time of initial presentation or with the size and site of tear to the final outcome.

  14. Fractures of the manubrium sterni: treatment options and a possible classification of different types of fractures

    PubMed Central

    Krinner, Sebastian; Oppel, Pascal; Grupp, Sina; Schulz-Drost, Melanie; Hennig, Friedrich F.; Langenbach, Andreas

    2018-01-01

    Background Sternum fractures are mostly located on the sternal corpus, seldom on the manubrium. Fractures of the sternal manubrium are, however, more frequently associated with severe concomitant injuries of thoracic organs, and therefore deserve special attention. In addition, in its function as a capstone in between the anterior chest wall and the shoulder girdle, it is exposed to a multiplicity of forces. Therefore the questions arise what types of fractures are observed in today’s clinical practice, how to classify them and which treatment options are available. This study reports on different types of fractures which involve the manubrium sterni. Methods Between January 2012 and October 2014, data was collected from all severely injured patients (ISS ≥16), which received a CT scan of the thorax in our Level-I-Trauma Center and retrospectively analyzed concerning sternal fractures. Fracture type, collateral injuries, age, and information about the circumstances of the accident were noted. Results Of 890 evaluable patients, 154 (17.3%) had a fracture of the sternum and 23 (2.6%) of the manubrium. Fractures of the manubrium appeared in following types: A-type—transverse fracture (n=11) in 1st intercostal space by direct blunt trauma or flexion of the torso with sagittal instability; B-type—oblique fracture (n=9) by seat belt injury with rotatory instability; C-type—combined, more fragmentary fracture (n=3) by direct blunt trauma with simultaneous flexion of the torso and multi directional instability. Fractures only little dislocation were treated conservatively, and unstable fractures were surgically stabilized (n=10). Conclusions In summary, three main types of fractures could be found. A-type fractures were stabilized with a longitudinal plate osteosynthesis and B-type fractures with transverse positioned plates. To treat complex C-type fractures, plates with a T- or H-form could be a good solution. Level of evidence: Level III retrospective

  15. Relationship Between the Lateral Center-Edge Angle and 3-Dimensional Acetabular Coverage.

    PubMed

    Wylie, James D; Kapron, Ashley L; Peters, Christopher L; Aoki, Stephen K; Maak, Travis G

    2017-04-01

    The lateral center-edge angle (LCEA) is an important measurement in understanding acetabular morphology and has had multiple interpretations. Misunderstanding of the LCEA and its relationship with acetabular 3-dimensional (3D) morphology may result in misdiagnosis and poor outcomes. To determine the discrepancy between bone-edge and sourcil-edge LCEA measurements on anteroposterior (AP) radiographs and to determine the 3D anatomic location of the sourcil-edge and bone-edge LCEA measurements. Cohort study (diagnosis); Level of evidence, 2. The LCEA was measured on radiographs to both the sourcil-edge and bone-edge on AP images of 60 symptomatic hips. On computed tomography (CT), coronal slices producing an LCEA matching the magnitude of each AP LCEA were identified. These coronal slices were mapped to a sagittal image of the acetabulum, which was divided into a standard clockface (3 = anterior, 12 = superior). We identified clockface locations corresponding to the AP sourcil-edge and bone-edge LCEA measurements. Paired t tests identified differences in magnitude and location of the bone and sourcil LCEAs. Limits of agreement were calculated for the differences between measures. Intraclass correlation coefficients (ICCs) assessed inter- and intraobserver repeatability. On the AP radiographs, the bone-edge LCEA was a mean 4.7° (95% CI, -4.0° to 13.3°) greater than the sourcil-edge LCEA ( P < .001). On CT, the sagittal clockface location of the sourcil-edge LCEA was more anterior compared with the sagittal clockface location of the maximum bone-edge LCEA (1:03 ± 0:42 vs 12:06 ± 0:30, respectively; P < .001). In hips with a difference >5° between sourcil-edge and bone-edge measurements, the coronal CT slice corresponding to the sourcil-edge LCEA was significantly more anterior (1:26 ± 0:35) than the CT slice corresponding to the bone-edge LCEA (11:46 ± 0:29; P < .001). This significant difference was similar in location but less pronounced in hips with a

  16. External fixation techniques for distal radius fractures.

    PubMed

    Capo, John T; Swan, Kenneth G; Tan, Virak

    2006-04-01

    Fractures of the distal radius are common injuries. Low-energy or high-energy mechanisms may be involved. Unstable distal radius fractures present a challenge to the treating orthopaedic surgeon. External fixation is a valuable instrument for fracture reduction and stabilization. Limited open incisions, early range of motion, and treatment of complex wounds are a few of the benefits of external fixation. Fixators may be spanning or nonbridging and may be used alone or in combination with other stabilization methods to obtain and maintain distal radius fracture reduction. Augmentation with percutaneous wires allows for optimal fracture stabilization with physiologic alignment of the wrist. Moderate distraction at the carpus does not induce postoperative stiffness. The distal radioulnar joint must be assessed and may need to be stabilized. Complications of external fixation are usually minor, but must be anticipated and treated early. Level V (expert opinion).

  17. Comparative evaluation of the vertical fracture resistance of endodontically treated roots filled with Gutta-percha and Resilon: a meta-analysis of in vitro studies.

    PubMed

    Tan, Minmin; Chai, Zhaowu; Sun, Chengjun; Hu, Bo; Gao, Xiang; Chen, Yunjia; Song, Jinlin

    2018-06-13

    Teeth treated endodontically are more susceptible to vertical root fracture (VRF). Some studies have suggested that obturating the root canals with Gutta-percha or Resilon can reinforce endodontically treated teeth, but a few others have presented conflicting results. These inconsistent results cannot guide clinicians in determining clinical approaches. The objective of this meta-analysis is to evaluate and compare the vertical fracture resistance of endodontically treated root canals obturated with Gutta-percha/AH plus and the Resilon system. Comprehensive literature searches were performed in the PubMed, Cochrane Library, ScienceDirect, Web of Science and Embase databases. The titles and abstracts of all of the retrieved articles were independently assessed by two authors according to predefined selection criteria. Data in the included articles were independently extracted. Statistical analyses were conducted using Review Manager 5.3 and Stata 12.0 software. The pooled standardized mean differences (SMDs) with 95% confidence intervals (CIs) were calculated for the outcome indicators. The level of statistical significance was set at p < 0.05. The Cochran Q test (I 2 test) was used to test for heterogeneity among studies. Fourteen randomized controlled in vitro trials were included in the meta-analysis. The results demonstrated that the vertical root fracture resistance of unprepared and unfilled roots was significantly higher than that of roots obturated with Gutta-percha/AH plus (SMD = - 0.69, 95% CI = - 1.34 to - 0.04, p = 0.04) or the Resilon system (SMD = - 0.54, 95% CI = - 1.07 to - 0.00, p = 0.05). The differences in fracture resistance between the roots filled with Gutta-percha/AH plus and the prepared unfilled root canals was not significant (SMD = 0.59, 95% CI = - 0.02 to 1.21, p = 0.06). Roots obturated with Resilon had higher fracture resistance than instrumented unfilled roots (SMD = 0.83, 95

  18. Tribological assessment of a flexible carbon-fibre-reinforced poly(ether-ether-ketone) acetabular cup articulating against an alumina femoral head.

    PubMed

    Scholes, S C; Inman, I A; Unsworth, A; Jones, E

    2008-04-01

    New material combinations have been introduced as the bearing surfaces of hip prostheses in an attempt to prolong their life by overcoming the problems of failure due to wear-particle-induced osteolysis. This will hopefully reduce the need for revision surgery. The study detailed here used a hip simulator to assess the volumetric wear rates of large-diameter carbon-fibre-reinforced pitch-based poly(ether-ether-ketone) (CFR-PEEK) acetabular cups articulating against alumina femoral heads. The joints were tested for 25 x 10(6) cycles. Friction tests were also performed on these joints to determine the lubrication regime under which they operate. The average volumetric wear rate of the CFR-PEEK acetabular component of 54 mm diameter was 1.16 mm(3)/10(6) cycles, compared with 38.6 mm(3)/10(6) cycles for an ultra-high-molecular-weight polyethylene acetabular component of 28 mm diameter worn against a ceramic head. This extremely low wear rate was sustained over 25 x 10(6) cycles (the equivalent of up to approximately 25 years in vivo). The frictional studies showed that the joints worked under the mixed-boundary lubrication regime. The low wear produced by these joints showed that this novel joint couple offers low wear rates and therefore may be an alternative material choice for the reduction of osteolysis.

  19. Inter- and intra-observer variability of radiography and computed tomography for evaluation of Zurich cementless acetabular cup placement ex vivo.

    PubMed

    Leasure, Jessica O; Peck, Jeffrey N; Villamil, Armando; Fiore, Kara L; Tano, Cheryl A

    2016-11-23

    To evaluate the inter- and intra-observer variability in measurement of the angle of lateral opening (ALO) and version angle measurement using digital radiography and computed tomography (CT). Each hemipelvis was implanted with a cementless acetabular cup. Ventrodorsal and mediolateral radiographs were made of each pelvis, followed by CT imaging. After removal of the first cup, the pelves were implanted with an acetabular cup in the contralateral acetabulum and imaging was repeated. Three surgeons measured the ALO and version angles three times for each cup from the mediolateral radiographic projection. The same measurements were made using three-dimensional multiplanar reconstructions from CT images. Two anatomical axes were used to measure pelvic inclination in the sagittal plane, resulting in six measurements per cup. Two-way repeated measures analysis of variance evaluated inter- and intra-observer repeatability for radiographic and CT-based measurements. Version angle based on radiographic measurement did not differ within surgeons (p = 0.433), but differed between surgeons (p <0.001). Radiographic measurement of ALO differed within surgeons (p = 0.006) but not between surgeons (p = 0.989). The ALO and version angle measured on CT images did not differ with or between surgeons. Assessment of inter- and intra-observer measurement of ALO and version angle was more reproducible using CT images than conventional mediolateral radiography for a Zurich cementless acetabular cup.

  20. Laser-treated stainless steel mini-screw implants: 3D surface roughness, bone-implant contact, and fracture resistance analysis

    PubMed Central

    Kang, He-Kyong; Chu, Tien-Min; Dechow, Paul; Stewart, Kelton; Kyung, Hee-Moon

    2016-01-01

    Summary Background/Objectives: This study investigated the biomechanical properties and bone-implant intersurface response of machined and laser surface-treated stainless steel (SS) mini-screw implants (MSIs). Material and Methods: Forty-eight 1.3mm in diameter and 6mm long SS MSIs were divided into two groups. The control (machined surface) group received no surface treatment; the laser-treated group received Nd-YAG laser surface treatment. Half in each group was used for examining surface roughness (Sa and Sq), surface texture, and facture resistance. The remaining MSIs were placed in the maxilla of six skeletally mature male beagle dogs in a randomized split-mouth design. A pair with the same surface treatment was placed on the same side and immediately loaded with 200g nickel–titanium coil springs for 8 weeks. After killing, the bone-implant contact (BIC) for each MSI was calculated using micro computed tomography. Analysis of variance model and two-sample t test were used for statistical analysis with a significance level of P <0.05. Results: The mean values of Sa and Sq were significantly higher in the laser-treated group compared with the machined group (P <0.05). There were no significant differences in fracture resistance and BIC between the two groups. Limitation: animal study Conclusions/Implications: Laser treatment increased surface roughness without compromising fracture resistance. Despite increasing surface roughness, laser treatment did not improve BIC. Overall, it appears that medical grade SS has the potential to be substituted for titanium alloy MSIs. PMID:25908868

  1. Patients with prior vertebral or hip fractures treated with teriparatide in the Direct Assessment of Nonvertebral Fractures in Community Experience (DANCE) observational study.

    PubMed

    Beall, D P; Feldman, R G; Gordon, M L; Gruber, B L; Lane, J M; Valenzuela, G; Yim, D; Alam, J; Krege, J H; Krohn, K

    2016-03-01

    In patients in the Direct Assessment of Nonvertebral Fractures in Community Experience (DANCE) observational study with and without a prior vertebral or hip fracture, the incidence of nonvertebral fractures was lower with >6 months of teriparatide treatment than during the first 6 months. Clinical evidence on the effect of teriparatide in patients with prior fracture is limited. In the DANCE observational study, the incidence of nonvertebral fragility fractures (NVFX) decreased significantly in patients receiving teriparatide for >6 months (6-24 months) versus >0 to ≤6 months (reference period). We performed a post hoc analysis to assess the effect of teriparatide 20 μg/day in patients who entered DANCE with prior vertebral or hip fractures. The incidence of patients experiencing a NVFX for four 6-month intervals during and after treatment was compared with the reference period. Overall, 4085 patients received ≥1 dose of teriparatide. Of 3720 with sufficient data for efficacy analysis, 692 had prior vertebral fracture, including 179 with previous kyphoplasty/vertebroplasty; 290 had prior hip fracture. These patients were older, and those with prior vertebral fractures had more comorbid conditions at baseline than those without prior vertebral fractures. The incidence of patients experiencing NVFX declined over time in all patient groups. The fracture incidence rate declined 49 and 46%, respectively, in patients with and without prior vertebral fracture and was 63 and 46% lower in patients with previous kyphoplasty/vertebroplasty and without prior vertebral fracture. NVFX declined 43 and 48% in patients with and without prior hip fracture. The reduced incidence over time was consistent in the subgroups (all interaction p values >0.05). Patients with prior fracture were more likely to experience serious adverse events. The incidence of NVFX decreased over time in patients receiving teriparatide in DANCE regardless of prior fracture status.

  2. Initial stability of cementless acetabular cups: press-fit and screw fixation interaction--an in vitro biomechanical study.

    PubMed

    Tabata, Tomonori; Kaku, Nobuhiro; Hara, Katsutoshi; Tsumura, Hiroshi

    2015-04-01

    Press-fit and screw fixation are important technical factors to achieve initial stability of a cementless acetabular cup for good clinical results of total hip arthroplasty. However, how these factors affect one another in initial cup fixation remains unclear. Therefore, this study aimed to evaluate the mutual influence between press-fit and screw fixation on initial cup stability. Foam bone was subjected to exact hemispherical-shape machining to diameters of 48, 48.5 and 49 mm. A compressive force was applied to ensure seating of a 48-mm-diameter acetabular cup in the foam bone prior to testing. Screws were inserted in six different conditions and tightened in a radial direction at the same torque strength. Then, the socket was rotated with a twist-testing machine, and the torque value at the start of axial rotation between the socket and the foam bone was measured under each screw condition. The torque values for the 48-mm-diameter reaming were >20 N m higher than those for the 48.5- and 49-mm-diameter reaming in each screw condition, indicating that press-fit fixation is stronger than screw fixation. Meanwhile, torque values for the 48.5- and 49-mm-diameter reaming tended to increase with increasing the number of screws. According to our experiment, press-fit fixation of a cementless acetabular cup achieved rigid stability. Although the supplemental screws increased stability of the implant under good press-fit conditions, they showed little impact on whole-cup stability. In the case of insufficient press-fit fixation, cup stability depends on screw stability and increasing the number of additional screws increases cup stability.

  3. Technical considerations for surgical intervention of Jones fractures.

    PubMed

    Mendicino, Robert W; Hentges, Matthew J; Mendicino, Michael R; Catanzariti, Alan R

    2013-01-01

    Jones fractures are a common injury treated by foot and ankle surgeons. Surgical intervention is recommended because of the high rate of delayed union, nonunion, and repeat fracture, when treated conservatively. Percutaneous intramedullary screw fixation is commonly used in the treatment of these fractures. We present techniques that can increase the surgical efficiency and decrease the complications associated with percutaneous delivery of internal fixation. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Patella Fracture Fixation with Suture and Wire: you Reap what you Sew

    PubMed Central

    Egol, Kenneth; Howard, Daniel; Monroy, Alexa; Crespo, Alexander; Tejwani, Nirmal; Davidovitch, Roy

    2014-01-01

    Introduction Operative fixation of displaced inferior pole patella fractures has now become the standard of care. This study aims to quantify clinical, radiographic and functional outcomes, as well as identify complications in a cohort of patients treated with non-absorbable braided suture fixation for inferior pole patellar fractures. These patients were then compared to a control group of patients treated for mid-pole fractures with K-wires or cannulated screws with tension band wiring. Methods In this IRB approved study, we identified a cohort of patients who were diagnosed and treated surgically for a displaced patella fracture. Demographic, injury, and surgical information were recorded. All patients were treated with a standard surgical technique utilizing non-absorbable braided suture woven through the patellar tendon and placed through drill holes to achieve reduction and fracture fixation. All patients were treated with a similar post-operative protocol and followed up at standard intervals. Data were collected concurrently at follow up visits. For purpose of comparison, we identified a control cohort with middle third patella fractures treated with either k-wires or cannulated screws and tension band technique. Patients were followed by the treating surgeon at regular follow-up intervals. Outcomes included self-reported function and knee range of motion compared to the uninjured side. Results Forty-nine patients with 49 patella fractures identified retrospectively were treated over 9 years. This cohort consisted of 31 females (63.3%) and 18 males (36.7%) with an average age of 57.1 years (range 26 - 88 years). Patients had an average BMI of 26.48 (range 19 - 44.08). Thirteen patients with inferior pole fractures underwent suture fixation and 36 patients with mid-pole fractures underwent tension band fixation (K-wire or cannulated screws with tension band). In the suture cohort, one fracture failed open repair (7.6%), which was revised again with sutures

  5. Patella fracture fixation with suture and wire: you reap what you sew.

    PubMed

    Egol, Kenneth; Howard, Daniel; Monroy, Alexa; Crespo, Alexander; Tejwani, Nirmal; Davidovitch, Roy

    2014-01-01

    Operative fixation of displaced inferior pole patella fractures has now become the standard of care. This study aims to quantify clinical, radiographic and functional outcomes, as well as identify complications in a cohort of patients treated with non-absorbable braided suture fixation for inferior pole patellar fractures. These patients were then compared to a control group of patients treated for mid-pole fractures with K-wires or cannulated screws with tension band wiring. In this IRB approved study, we identified a cohort of patients who were diagnosed and treated surgically for a displaced patella fracture. Demographic, injury, and surgical information were recorded. All patients were treated with a standard surgical technique utilizing non-absorbable braided suture woven through the patellar tendon and placed through drill holes to achieve reduction and fracture fixation. All patients were treated with a similar post-operative protocol and followed up at standard intervals. Data were collected concurrently at follow up visits. For purpose of comparison, we identified a control cohort with middle third patella fractures treated with either k-wires or cannulated screws and tension band technique. Patients were followed by the treating surgeon at regular follow-up intervals. Outcomes included self-reported function and knee range of motion compared to the uninjured side. Forty-nine patients with 49 patella fractures identified retrospectively were treated over 9 years. This cohort consisted of 31 females (63.3%) and 18 males (36.7%) with an average age of 57.1 years (range 26-88 years). Patients had an average BMI of 26.48 (range 19-44.08). Thirteen patients with inferior pole fractures underwent suture fixation and 36 patients with mid-pole fractures underwent tension band fixation (K-wire or cannulated screws with tension band). In the suture cohort, one fracture failed open repair (7.6%), which was revised again with sutures and progressed to union. Of the 36

  6. An assessment of fracture resistance of three composite resin core build-up materials on three prefabricated non-metallic posts, cemented in endodontically treated teeth: an in vitro study

    PubMed Central

    Pal, Bhupinder; Pujari, Prashant

    2015-01-01

    Endodontically treated teeth with excessive loss of tooth structure would require to be restored with post and core to enhance the strength and durability of the tooth and to achieve retention for the restoration. The non-metallic posts have a superior aesthetic quality. Various core build-up materials can be used to build-up cores on the posts placed in endodontically treated teeth. These materials would show variation in their bonding with the non-metallic posts thus affecting the strength and resistance to fracture of the remaining tooth structure. Aims. The aim of the study was to assess the fracture resistance of three composite resin core build-up materials on three prefabricated non-metallic posts, cemented in extracted endodontically treated teeth. Material and Methods. Forty-five freshly extracted maxillary central incisors of approximately of the same size and shape were selected for the study. They were divided randomly into 3 groups of 15 each, depending on the types of non-metallic posts used. Each group was further divided into 3 groups (A, B and C) of 5 samples each depending on three core build-up material used. Student’s unpaired ‘t’ test was also used to analyse and compare each group with the other groups individually, and decide whether their comparisons were statistically significant. Results. Luxacore showed the highest fracture resistance among the three core build-up materials with all the three posts systems. Ti-core had intermediate values of fracture resistance and Lumiglass had the least values of fracture resistance. PMID:25755926

  7. The effect of bearing friction torques on the primary stability of press-fit acetabular cups: A novel in vitro method.

    PubMed

    Alexander, Jahnke; Stefan, Schroeder; Alfonso, Fonseca Ulloa Carlos; Adam, Ahmed Gafar; Alexander, Ishaque Bernd; Markus, Rickert

    2018-05-10

    Aseptic loosening is the main reason for revision of total hip arthroplasty, and relative micromotions between cementless acetabular cups and bone play an important role regarding their comparatively high loosening rate. Therefore, the aim of the present study was to analyze the influence of resulting frictional torques on the primary stability of press-fit acetabular cups subjected to two different bearing partners. A cementless press-fit cup was implanted in bone-like foam. Primary stability of the cup was analyzed by determining spatial total, translational and rotational interface micromotions by means of an eddy current sensor measuring system. Torque transmission into the cup was realized by three synchronous servomotors considering resultant friction torques based on constant friction for ceramic-on-ceramic (CoC: µ = 0.044; max. resultant torque: 1.5 Nm) and for ceramic-on-polyethylene (CoP: µ = 0.063; max. resultant torque: 1.9 Nm) bearing partners. Rotational micromotion of CoC was 8.99 ± 0.85µm and of CoP 13.39 ± 1.43µm. Translational micromotion of CoC was 29.93 ± 1.44µm and of CoP 39.91 ± 2.25µm. Maximum total relative micromotions were 37.10 ± 1.07µm for CoC and 51.64 ± 2.18µm for CoP. Micromotions resulting from CoC were statistically lower than those resulting from CoP (p < 0.05). The described 3D-measuring set-up offers a novel in vitro method of measuring primary stability of acetabular cups. We can therefore conclude, that primary stability of acetabular cup systems can be observed using either the lower friction curve (CoC) or the higher friction curve (CoP). In future studies different cup designs or cup fixation mechanisms may be tested and compared in vitro and assessed prior to implantation. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  8. Management of Simple Clavicle Fractures by Primary Care Physicians.

    PubMed

    Stepanyan, Hayk; Gendelberg, David; Hennrikus, William

    2017-05-01

    The clavicle is the most commonly fractured bone. Children with simple fractures are often referred to orthopedic surgeons by primary care physician to ensure adequate care. The objective of this study was to show that simple clavicle fractures have excellent outcomes and are within the scope of primary care physician's practice. We performed a retrospective chart review of 16 adolescents with simple clavicle fractures treated with a sling. Primary outcomes were bony union, pain, and function. The patients with simple clavicle fractures had excellent outcomes with no complications or complaints of pain or restriction of their activities of daily living. The outcomes are similar whether treated by an orthopedic surgeon or a primary care physician. The cost to society and the patient is less when the primary care physician manages the fracture. Therefore, primary care physicians should manage simple clavicle fractures.

  9. Initial stability of a highly porous titanium cup in an acetabular bone defect model.

    PubMed

    Yoshimoto, Kensei; Nakashima, Yasuharu; Wakiyama, Miyo; Hara, Daisuke; Nakamura, Akihiro; Iwamoto, Mikio

    2018-04-12

    The purpose of this study was to quantify the initial stability of a highly porous titanium cup using an acetabular bone defect model. The maximum torque of a highly porous titanium cup, with a pore size of 640 μm and porosity of 60%, was measured using rotational and lever-out torque testing and compared to that of a titanium-sprayed cup. The bone models were prepared using a polyurethane foam block and had three levels of bone coverage: 100, 70, and 50%. The highly porous titanium cup demonstrated significantly higher maximum torque than the titanium-sprayed cups in the three levels of bone defects. On rotational torque testing, it was found to be 1.5, 1.3, and 1.3 times stronger than the titanium-sprayed cups with 100, 70 and 50% bone coverage, respectively. Furthermore, it was found to be 2.2, 2.3, and 1.5 times stronger on lever-out testing than the titanium-sprayed cup. No breakage in the porous layers was noted during the testing. This study provides additional evidence of the initial stability of highly porous titanium cup, even in the presence of acetabular bone defects. Copyright © 2018. Published by Elsevier B.V.

  10. A discrete fracture model for two-phase flow in fractured porous media

    NASA Astrophysics Data System (ADS)

    Gläser, Dennis; Helmig, Rainer; Flemisch, Bernd; Class, Holger

    2017-12-01

    A discrete fracture model on the basis of a cell-centered finite volume scheme with multi-point flux approximation (MPFA) is presented. The fractures are included in a d-dimensional computational domain as (d - 1)-dimensional entities living on the element facets, which requires the grid to have the element facets aligned with the fracture geometries. However, the approach overcomes the problem of small cells inside the fractures when compared to equi-dimensional models. The system of equations considered is solved on both the matrix and the fracture domain, where on the prior the fractures are treated as interior boundaries and on the latter the exchange term between fracture and matrix appears as an additional source/sink. This exchange term is represented by the matrix-fracture fluxes, computed as functions of the unknowns in both domains by applying adequate modifications to the MPFA scheme. The method is applicable to both low-permeable as well as highly conductive fractures. The quality of the results obtained by the discrete fracture model is studied by comparison to an equi-dimensional discretization on a simple geometry for both single- and two-phase flow. For the case of two-phase flow in a highly conductive fracture, good agreement in the solution and in the matrix-fracture transfer fluxes could be observed, while for a low-permeable fracture the discrepancies were more pronounced. The method is then applied two-phase flow through a realistic fracture network in two and three dimensions.

  11. Atlas Fractures and Atlas Osteosynthesis: A Comprehensive Narrative Review.

    PubMed

    Kandziora, Frank; Chapman, Jens R; Vaccaro, Alexander R; Schroeder, Gregory D; Scholz, Matti

    2017-09-01

    Most atlas fractures are the result of compression forces. They are often combined with fractures of the axis and especially with the odontoid process. Multiple classification systems for atlas fractures have been described. For an adequate diagnosis, a computed tomography is mandatory. To distinguish between stable and unstable atlas injury, it is necessary to evaluate the integrity of the transverse atlantal ligament (TAL) by magnetic resonance imaging and to classify the TAL lesion. Studies comparing conservative and operative management of unstable atlas fractures are unfortunately not available in the literature; neither are studies comparing different operative treatment strategies. Hence all treatment recommendations are based on low level evidence. Most of atlas fractures are stable and will be successfully managed by immobilization in a soft/hard collar. Unstable atlas fractures may be treated conservatively by halo-fixation, but nowadays more and more surgeons prefer surgery because of the potential discomfort and complications of halo-traction. Atlas fractures with a midsubstance ligamentous disruption of TAL or severe bony ligamentous avulsion can be treated by a C1/2 fusion. Unstable atlas fractures with moderate bony ligamentous avulsion may be treated by atlas osteosynthesis. Although the evidence for the different treatment strategies of atlas fractures is low, atlas osteosynthesis has the potential to change treatment philosophies. The reasons for this are described in this review.

  12. G7 BiSpherical Acetabular Shell PMCF Study

    ClinicalTrials.gov

    2017-11-22

    Rheumatoid Arthritis; Osteoarthritis; Noninflammatory Degenerative Joint Disease; Avascular Necrosis; Correction of Functional Deformity; Non-Union Fracture; Femoral Neck Fractures; Trochanteric Fractures

  13. Bilateral Femoral Neck Fractures in Cerebrotendinous Xanthomatosis Treated by Hip Arthroplasties: The First Case Report and Literature Review.

    PubMed

    Wejjakul, Witchuree; Chatmaitri, Swist; Wattanarojanaporn, Thongek; Pongkunakorn, Anuwat; Ittiwut, Chupong; Shotelersuk, Vorasuk

    2017-01-01

    Cerebrotendinous xanthomatosis (CTX) is a rare autosomal recessive lipid storage disease caused by mutations of the CYP27A1 gene and deficiency of the sterol-27-hydroxylase enzyme in bile acid biosynthesis. It is characterized by the accumulation of cholestanol and bile alcohols in plasma, the formation of xanthomatous lesions in various tissues, and organ degeneration. This disorder is also associated with osteoporosis and increased risk of fracture. To date, only two CTX patients with femoral neck fractures have been reported. Neither was treated by arthroplasties, and the operative outcomes are lacking. We report the case of a 46-year-old Thai female who presented with consecutive bilateral femoral neck fractures following minor trauma within a 3-year period and received cementless bipolar hemiarthroplasties. Her phenotypic expression included Achilles tendon masses, childhood-onset cataracts, intellectual disability, and cerebellar ataxia. A brain computed tomography showed non-enhancing hypodense lesions in the bilateral cerebellar hemispheres with mild brain atrophy. Histopathology from an Achilles tendon biopsy revealed tendinous xanthoma and molecular analysis confirmed a homozygous nonsense mutation, c.1072C>T (p.Gln358Ter), in exon 6 of the CYP27A1 gene. The intra-operative crack of a calcar femorale was a major complication during both prosthetic insertion surgeries and warranted cerclage wiring. At the 7-month follow-up of the right hip and the 41-month follow-up of the left hip, postoperative radiographs showed well-fixed and well-aligned prostheses. Independent household ambulation could be resumed with Harris hip scores of 81 points equally. CTX is associated with osteoporosis, and middle-aged patients could present with femoral neck fracture following minor trauma. Cementless bipolar hemiarthroplasty for a totally displaced fracture is justified for a patient who has cognitive impairment. Intra-operative fracture is a major complication during

  14. Fracture of the medial intercondylar eminence of the tibia in horses treated by arthroscopic fragment removal (21 horses).

    PubMed

    Rubio-Martínez, L M; Redding, W R; Bladon, B; Wilderjans, H; Payne, R J; Tessier, C; Geffroy, O; Parker, R; Bell, C; Collingwood, F A

    2018-01-01

    Fractures of the medial intercondylar eminence of the tibia (MICET) are scarcely reported in horses. To report the clinical and diagnostic findings, surgical treatment and outcome in a series of horses presented with MICET fracture and treated with arthroscopic fragment removal. Multicentre retrospective case series. Case records of horses diagnosed with MICET fractures that had undergone surgical treatment were reviewed. Follow-up information was obtained from re-examination visits and/or owners. Twenty-one cases were identified at 9 equine hospitals between 2004 and 2016. A history of trauma and acute onset of lameness was reported in 12 horses. All cases underwent fracture removal via arthroscopy of the medial femorotibial joint. The cranial cruciate ligament was intact in 6 horses and damaged in 15 horses (damage was ≤25% [n = 9], 25-50% [n = 4] or ≥50% [n = 2] of the cross-sectional area). The cranial ligament of the medial meniscus was damaged in 11 horses (≤25% [n = 8], 25-50% [n = 3]). The medial meniscus was damaged in 5 horses and articular cartilage damage was identified in 14 horses (mild [n = 8], moderate [n = 6]). Follow-up information (median 14 months; 4 months-6 years) was available for 20 cases; 2 horses were sound but convalescing; 13 horses were sound and returned to their previous or expected use. Of the 4 horses with the most severe changes to the articular soft tissue structures, 2 remained lame and 2 were subjected to euthanasia because of persistent lameness. The retrospective, multicentre nature of this study and the limited number of horses are the main limitations. Fractures of the MICET are commonly associated with a traumatic event. Prompt diagnosis and early arthroscopic removal of the fracture are recommended. © 2017 The Authors. Equine Veterinary Journal published by John Wiley & Sons Ltd on behalf of EVJ Ltd.

  15. [Biomechanical significance of the acetabular roof and its reaction to mechanical injury].

    PubMed

    Domazet, N; Starović, D; Nedeljković, R

    1999-01-01

    The introduction of morphometry into the quantitative analysis of the bone system and functional adaptation of acetabulum to mechanical damages and injuries enabled a relatively simple and acceptable examination of morphological acetabular changes in patients with damaged hip joints. Measurements of the depth and form of acetabulum can be done by radiological methods, computerized tomography and ultrasound (1-9). The aim of the study was to obtain data on the behaviour of acetabular roof, the so-called "eyebrow", by morphometric analyses during different mechanical injuries. Clinical studies of the effect of different loads on acetabular roof were carried out in 741 patients. Radiographic findings of 400 men and 341 women were analysed. The control group was composed of 148 patients with normal hip joints. Average age of the patients was 54.7 years and that of control subjects 52.0 years. Data processing was done for all examined patients. On the basis of our measurements the average size of female "eyebrow" ranged from 24.8 mm to 31.5 mm with standard deviation of 0.93 and in men from 29.4 mm to 40.3 mm with standard deviation of 1.54. The average size in the whole population was 32.1 mm with standard deviation of 15.61. Statistical analyses revealed high correlation coefficients between the age and "eyebrow" size in men (r = 0.124; p < 0.05); it was statically in inverse proportion (Graph 1). However, in female patients the correlation coefficient was statistically significant (r = 0.060; p > 0.05). The examination of the size of collodiaphysial angle and length of "eyebrow" revealed that "eyebrow" length was in inverse proportion to the size of collodiaphysial angle (r = 0.113; p < 0.05). The average "eyebrow" length in relation to the size of collodiaphysial angle ranged from 21.3 mm to 35.2 mm with standard deviation of 1.60. There was no statistically significant correlation between the "eyebrow" size and Wiberg's angle in male (r = 0.049; p > 0.05) and

  16. How well can step-off and gap distances be reduced when treating intra-articular distal radius fractures with fragment specific fixation when using fluoroscopy.

    PubMed

    Thiart, M; Ikram, A; Lamberts, R P

    2016-12-01

    Although fragment specific fixation has proved to be an effective treatment regime, it has not been established how successfully this treatment could be performed using fluoroscopy and what the added value of arthroscopy could be. Establish gap and step-off distances after in intra-articular distal radius fractures that have been treated with fragment specific fixation while using fluoroscopy. Forty-four patients with an intra-articular distal radius fracture were treated with fragment specific fixation while using fluoroscopy. After the treatment of the intra-articular distal radius fracture with fragment specific fixation and the use of fluoroscopy, but before the completion of the surgical intervention, all gap, and step-off distances were determined by using arthroscopy. In addition, the joint was checked for any other wrist pathologies. Arthroscopy after the surgical intervention showed that in 37 patients no gap distances could be detected, while in six patients a gap distance of≤2mm was found and in one patient, a gap distance of 3mm. Similarly, arthroscopy revealed no step-off distances in 33 patients, while in 11 patients a step-off distance of≤2mm was found. Although additional wrist pathologies were found in 48% of our population, only one patient needed surgical intervention. Three months after the surgical intervention wrist flexion was 41±10°, wrist extension 51±17°, ulnar deviation 19±10°, radial deviation 32±12° while patients could pronate and supinate their wrist to 85±5° and 74±20°, respectively. Intra-articular distal radius fractures can be treated successfully with fragment specific fixation and the use of fluoroscopy. As almost all gap and step-off distances could be reduced to an acceptable level, the scope for arthroscopy to further improve this treatment regime is limited. The functional outcome scores that were found 3 months after the surgical intervention were similar to what has been reported in other studies using

  17. Adoption of Robotic vs Fluoroscopic Guidance in Total Hip Arthroplasty: Is Acetabular Positioning Improved in the Learning Curve?

    PubMed

    Kamara, Eli; Robinson, Jonathon; Bas, Marcel A; Rodriguez, Jose A; Hepinstall, Matthew S

    2017-01-01

    Acetabulum positioning affects dislocation rates, component impingement, bearing surface wear rates, and need for revision surgery. Novel techniques purport to improve the accuracy and precision of acetabular component position, but may have a significant learning curve. Our aim was to assess whether adopting robotic or fluoroscopic techniques improve acetabulum positioning compared to manual total hip arthroplasty (THA) during the learning curve. Three types of THAs were compared in this retrospective cohort: (1) the first 100 fluoroscopically guided direct anterior THAs (fluoroscopic anterior [FA]) done by a surgeon learning the anterior approach, (2) the first 100 robotic-assisted posterior THAs done by a surgeon learning robotic-assisted surgery (robotic posterior [RP]), and (3) the last 100 manual posterior (MP) THAs done by each surgeon (200 THAs) before adoption of novel techniques. Component position was measured on plain radiographs. Radiographic measurements were taken by 2 blinded observers. The percentage of hips within the surgeons' "target zone" (inclination, 30°-50°; anteversion, 10°-30°) was calculated, along with the percentage within the "safe zone" of Lewinnek (inclination, 30°-50°; anteversion, 5°-25°) and Callanan (inclination, 30°-45°; anteversion, 5°-25°). Relative risk (RR) and absolute risk reduction (ARR) were calculated. Variances (square of the standard deviations) were used to describe the variability of cup position. Seventy-six percentage of MP THAs were within the surgeons' target zone compared with 84% of FA THAs and 97% of RP THAs. This difference was statistically significant, associated with a RR reduction of 87% (RR, 0.13 [0.04-0.40]; P < .01; ARR, 21%; number needed to treat, 5) for RP compared to MP THAs. Compared to FA THAs, RP THAs were associated with a RR reduction of 81% (RR, 0.19 [0.06-0.62]; P < .01; ARR, 13%; number needed to treat, 8). Variances were lower for acetabulum inclination and anteversion in RP

  18. Mating of a PROSTALAC spacer with an intramedullary nail for reconstruction of an infected interprosthetic femoral shaft fracture: a case report.

    PubMed

    Kamath, Atul F; Austin, Daniel; Lee, Gwo-Chin

    2012-08-01

    Reconstruction for concurrent infection of an ipsilateral total hip arthroplasty (THA) and total knee arthroplasty (TKA) is a challenge. We report a 2-stage reconstruction of a THA for chronic infection of both the THA and TKA with severe femoral bone loss secondary to interprosthetic fractures. The reconstruction involved using a custom-made, temporary, antibiotic-impregnated PROSTALAC spacer mated with an intramedullary nail. The acetabulum was then exposed and the necrotic cartilage was removed and curetted. The acetabulum was reamed to accept a PROSTALAC acetabular shell. The shell was cemented into the acetabulum with antibiotic cement. The custom-made spacer was then inserted distally first into the tibia. The distal end of the intramedullary nail was interlocked with a bicortical bolt to minimise nail rotation. Antibiotic-impregnated cement was moulded around the nail and spacer. The proximal end of the spacer was then reduced into the acetabular socket, and the joint was irrigated and the wound closed. A customised abduction brace was fitted, and partial weight bearing was allowed. Sufficient leg length, soft-tissue tension, and range of hip motion were restored, and a total femur and constrained liner was re-implanted 4 months later. Mating of an intramedullary nail with a PROSTALAC spacer is a viable reconstructive option.

  19. Orbital fractures due to domestic violence: an epidemiologic study.

    PubMed

    Goldberg, Stuart H.; McRill, Connie M.; Bruno, Christopher R.; Ten Have, Tom; Lehman, Erik

    2000-09-01

    Domestic violence is an important cause of orbital fractures in women. Physicians who treat patients with orbital fractures may not suspect this mechanism of injury. The purpose of this study was to assess the association between domestic violence and orbital fractures. A medical center-based case-control study with matching on age and site of admission was done. Medical center databases were searched using ICD-9 codes to identify all cases of orbital fractures encountered during a three-year period. Medical records of female patients age 13 and older were reviewed along with those of age, gender and site of admission matched controls. A stratified exact test was employed to test the association between domestic violence and orbital fracture. Among 41 adult female cases with orbital fractures treated at our medical center, three (7.3%) reported domestic violence compared to zero among the matched controls (p = 0.037). We believe that domestic violence may be under-reported in both orbital fracture cases and controls. This may result in an underestimate of the orbital fracture versus domestic violence association. Domestic violence is a serious women's health and societal problem. Domestic violence may have a variety of presentations, including illnesses and injuries. Orbital fracture is an identifiable manifestation of domestic violence. Domestic violence is more likely to be detected in adult female hospital patients with orbital fracture than in matched controls with any other diagnosis. Physicians who treat patients with orbital fractures should be familiar with this mechanism of injury.

  20. Intercondylar humerus fracture- parallel plating and its results.

    PubMed

    Kumar, Sanjiv; Singh, Sudhir; Kumar, Dharmender; Kumar, Neeraj; Verma, Reetu

    2015-01-01

    Intercondylar fracture of humerus is one of the commonest fractures of young adult and counts for about 30% of all elbow fractures. The treatment of these fractures continues to present challenges despite advances in internal fixation. Although orthogonal plating use to provid adequate functional results in these fractures, parallel plating is said to be mechanically more stable construct thus allowing early mobilization and better range of motion. AIM of the study is to assess the clinical as well functional results of these fractures treated with parallel plating. Prospective study in a tertiary care hospital. A total of 23 fresh patients of intercondylar fracture of humerus from Jan 2013 to May 2014 were included in the study and were treated with parallel plating. These patients were followed at 3, 6, 12, 24 weeks and at 1year of follow up and assessed in terms of time for union, range of motion, MAYO score, DASH score and complication rate. At final follow up Mayo score was 96.32±04.96 from 5.00±01.26 and DASH SCORE was 31.42±2.04 which dropped from 150±05.34, Range of motion improved from 21.38±05.70 to 116.1±07.92 with 100% union rate and complications less than 19%. Parallel plating for intercondylar fracture of humerus is excellent method of fixation and results are similar to those treated with orthogonal plating.

  1. Is metal-on-metal squeaking related to acetabular angle of inclination?

    PubMed

    Bernasek, Thomas; Fisher, David; Dalury, David; Levering, Melissa; Dimitris, Kirk

    2011-09-01

    Postoperative audible squeaking has been well documented in ceramic-on-ceramic hip prostheses, and several metal-on-metal (MOM) THA designs, specifically those used for large-head resurfacing and MOM polyethylene sandwich designs, and are attributed to different implant- and patient-specific factors. Current literature does not identify the incidence of squeaking in modular MOM THA or possible etiologic factors. Our purposes were to (1) identify the incidence of squeaking in modular MOM prostheses in THA; (2) determine whether males or females were more likely to have squeaking; and (3) determine whether the incidence of squeaking relates to acetabular inclination angle. We retrospectively reviewed the patient records and radiographs of 539 patients (542 hips) from three independent centers who underwent a MOM THA between February 2001 and December 2005. Demographic and implant factors were evaluated, including measurement of cup inclination angles. The minimum followup was 36 months (mean, 76 months; range, 36-119 months). We identified squeaking in eight of the 542 hips (1.5%); five were in women and two were in men (one patient had bilateral squeaking). The time to onset of patient-reported audible squeaking averaged 23 months (range, 6-84 months). Squeaking was more likely to occur in women (six of eight hips). No hips with 45º or less acetabular inclination squeaked (291 hips); eight of 251 hips (3.2%) with inclination angles greater than 45º squeaked. Patients who reported squeaking had higher inclination angles than those who did not report squeaking. Our observations suggest an increased frequency of squeaking in female patients and in patients with greater inclination angles with this MOM implant design.

  2. Overtreatment of displaced midshaft clavicle fractures.

    PubMed

    Ban, Ilija; Nowak, Jan; Virtanen, Kaisa; Troelsen, Anders

    2016-12-01

    Background and purpose - The best treatment for displaced clavicle fractures has been debated for decades. Operative treatment has become more common. However, several randomized trials comparing non-operative and operative treatment have not shown any compelling evidence in favor of surgery. We identified the preferred treatment of displaced midshaft clavicle fractures at public hospitals in 3 countries in Scandinavia. Patients and methods - A purpose-made multiple-choice questionnaire in English was sent to all public hospitals in Denmark, Sweden, and Finland. This was addressed to the orthopedic surgeon responsible for treatment of clavicle fractures, and completed questionnaires were obtained from 85 of 118 hospitals. Results - In the 3 countries, 69 of the 85 hospitals that responded would treat displaced clavicle fractures operatively. Clear criteria for treatment allocation were used at 58 of the hospitals, with the remaining 27 using individual assessment in collaboration with the patient. Precontoured locking plates were mostly used, placed either superiorly (64/85) or anteriorly (10/85). Interpretation - Displaced midshaft clavicle fractures are mainly treated operatively in Sweden, Denmark, and Finland. This treatment is not supported by compelling evidence.

  3. Clinical and radiographic outcomes of femoral head fractures: excision vs. fixation of fragment in Pipkin type I: what is the optimal choice for femoral head fracture?

    PubMed

    Park, Kyung-Soon; Lee, Keun-Bae; Na, Bo-Ram; Yoon, Taek-Rim

    2015-07-01

    In this work, we present relatively long-term results of femoral head fractures with a specific focus on Pipkin type I fractures. Fifty-nine femoral head fractures were treated according to modified Pipkin's classification as follows: type I, small fragment distal to the fovea centralis (FC); type II, large fragment distal to the FC; type III, large fragment proximal to the FC; type IV, comminuted fracture. There were 15 cases of type I, 28 of type II, 9 of type III, and 7 of type IV fractures. Conservative treatment with skeletal traction was performed in 4 type II cases, excision of the fragment in 15 type I and 10 type II cases, fixation of the fragment in 14 type II and all 9 type III cases, and total hip replacement in all 7 type IV cases. The overall clinical and radiographic outcomes were evaluated using previously published criteria, focusing on the results in Pipkin type I fractures with relatively large fragments. Based on Epstein criteria, in type II fractures, excellent or good clinical results were seen in 6 of 10 patients (60.0 %) treated by excision of the fragment and 12 of 14 patients (85.7 %) treated by internal fixation (p = 0.05). Also, excellent or good radiologic results were seen in 4 of 10 (40.0 %) patients treated by excision of the fragment and 12 of 14 (85.7 %) patients treated by internal fixation (p = 0.03). Even in Pipkin type I fractures, if the fragment is large (modified Pipkin type II), early reduction and internal fixation can produce good results.

  4. Periprosthetic fractures of the humerus.

    PubMed

    McDonough, Edward B; Crosby, Lynn A

    2005-12-01

    Periprosthetic humeral fractures present a treatment challenge for the orthopedic surgeon. The overall incidence of fracture is between 0.5% and 3%, with the majority of fractures occurring intraoperatively and involving the humeral diaphysis. Excess torque produced during surgery is usually responsible for intraoperative fractures. Improper canal preparation or prosthetic placement may also increase the chance of sustaining a fracture. Postoperative fractures are most commonly caused by minor trauma, such as a fall. Poor bone quality, female sex, advanced age, and history of rheumatoid arthritis are the risk factors most commonly associated with periprosthetic fractures. All 4 systems used to describe periprosthetic humeral shaft fractures classify fracture patterns according to the anatomic relation of the fracture to the prosthetic stem. Treatment decisions should be made with respect to obtaining fracture stability, initiating early gleno-humeral motion, and restoring shoulder function. Intraoperative fractures and any postoperative fracture resulting in prosthetic instability should be treated with a long-stem prosthesis extending at least 2 to 3 cortical diameters past the fracture site with consideration for rigid plate fixation. Short oblique or transverse postoperative fractures should be managed with early stable fixation. There has been some support for conservative treatment of long oblique or spiral postoperative fractures. Postoperative diaphyseal fractures distal to the stem generally are well maintained with standard fracture management.

  5. A pilot trial comparing the tear-out behavior in screw-sockets and cemented polyethylene acetabular components - a cadaveric study.

    PubMed

    Möbius, R; Schleifenbaum, S; Grunert, R; Löffler, S; Werner, M; Prietzel, T; Hammer, N

    2016-10-01

    The removal of well-fixed acetabular components following THA (total hip arthroplasty) is a difficult operation and could be accompanied by the loss of acetabular bone stock. The optimal method for fixation is still under debate. The aim of this pilot study was to compare the tear-out resistance and failure behavior between osseo-integrated and non-integrated screw cups. Furthermore, we examined whether there are differences in the properties mentioned between screw sockets and cemented polyethylene cups. Tear-out resistance and related mechanical work required for the tear-out of osseo-integrated screw sockets are higher than in non-integrated screw sockets. Ten human coxal bones from six cadavers with osseo-integrated screw sockets (n=4), non-integrated (implanted post-mortem, n=3) screw sockets and cemented polyethylene cups (n=3) were used for tear-out testing. The parameters axial failure load and mechanical work for tear-out were introduced as measures for determining the stability of acetabular components following THA. The osseo-integrated screw sockets yielded slightly higher tear-out resistance (1.61±0.26kN) and related mechanical work compared to the non-integrated screw sockets (1.23±0.39kN, P=0.4). The cemented polyethylene cups yielded the lowest tear-out resistance with a failure load of 1.18±0.24kN. Compared to the screw cups implanted while alive, they also differ on a non-significant level (P=0.1). Osseous failure patterns differed especially for the screw sockets compared to the cemented polyethylene cups. Osseo-integration did not greatly influence the tear-out stability in cementless screw sockets following axial loading. Furthermore, the strength of the bone-implant-interface of cementless screw sockets appears to be similar to cemented polyethylene cups. However, given the high failure load, high mechanical load and because of the related bone failure patterns, removal should not be performed by means of tear-out but rather by osteotomes

  6. Ultrasound diagnosis of penile fracture.

    PubMed

    Nomura, Jason T; Sierzenski, Paul R

    2010-04-01

    Rupture of the corpus cavernosum, penile fracture, is an uncommon occurrence. Diagnosis is straightforward when classical historical and physical examination findings are present. However, atypical presentations can make the diagnosis difficult. Review the literature supporting use of ultrasound for the diagnosis of penile fracture. Review of the ultrasonographic findings in patients with penile fracture. A 32-year-old man presented with penile ecchymosis after sex but lacking several historical and physical examination elements for a diagnosis of penile fracture. Ultrasound performed by the treating physician revealed rupture of the tunica albuginea and presence of a hematoma, leading to a diagnosis of penile fracture. Ultrasound is a simple, efficient, and non-invasive imaging method to assist in the diagnosis of penile fracture. Copyright 2010 Elsevier Inc. All rights reserved.

  7. Facial Fracture Management in Northwest Nigeria

    PubMed Central

    Taiwo, Abdurrazaq Olanrewaju; Soyele, Olujide Oladele; Godwin, Ndubuizi Ugochukwu; Ibikunle, Adebayo Aremu

    2013-01-01

    Background: Facial fracture is gradually become a public health problem in our community due to the attendant morbidity and mortality. Hence, the aim of this study was to determine the pattern of facial fracture in Dental and Maxillofacial Surgery Department of Usmanu Danfodiyo University Teaching Hospital. This cross-sectional study was undertaken to provide information regarding gender, age, etiology, and diagnosis of patients with maxillofacial fractures. Materials and Methods: A 1-year review of patients diagnosed and treated for facial fractures in Usmanu Danfodiyo University Teaching Hospital between January 2011 and December 2011. The diagnosis was based on radiographic data and clinical examination. The main analysis outcome measures were etiology, age, gender, site, and treatment. Data were organized and presented by means of descriptive statistics and Pearson's Chi-square test. The level of significance adopted was 5%. Results: A total of 40 patients were treated in this period. Over 95% were male, 81% were caused by road traffic crash (RTC) and 86.4% were in the 21-30 years group. Most patients (52%) had mandibular fractures, and the most common site was the body. Most patients with midfacial fractures had fractures of the zygomaticomaxillary region (36%), while fractures of the parasymphyseal region were more common in the mandible 156 (31%). The most common treatment for jaw fractures was mandibulomaxillary fixation (MMF). Stable zygomatic complex fractures were reduced (elevated) intraorally, and unstable ones were supported by antral packs. Conclusions: This study highlights facial fractures secondary to RTC as a serious public health problem in our environment. Preventive strategies remain the cheapest way to reduce direct and indirect costs of the sequelae of RTC. It also bring to the fore the necessity to shift to open reduction and internal fixation (ORIF) of fractures. PMID:24741422

  8. Complex tibial fracture outcomes following treatment with low-intensity pulsed ultrasound.

    PubMed

    Leung, Kwok-Sui; Lee, Wing-Sze; Tsui, Hon-For; Liu, Paul Po-Lung; Cheung, Wing-Hoi

    2004-03-01

    A clinical study was conducted to investigate the effect of low-intensity pulsed ultrasound (US) stimulation (LIPUS) on the healing of complex tibial fractures. Thirty complex tibial fractures were randomly assigned to the treatment with LIPUS (n = 16) or by a dummy machine (sham-exposed: n = 14). The fractures were immobilized by either internal or external fixations according to the clinical indications. LIPUS was given 20 min/day for 90 days. Fracture healing was monitored by clinical, radiological, densitometric and biochemical assessments. The LIPUS-treated group showed statistically significantly better healing, as demonstrated by all assessments. Complications were minimal in the LIPUS group. There were two cases of delayed union, with one in each group. There were two cases of infection in the control group. The delayed-union cases were subsequently treated by LIPUS and the infection cases were treated with standard protocol. Fracture healing in these patients was again treated by LIPUS.

  9. Advantages of external hybrid fixators for treating Schatzker V-VI tibial plateau fractures: A retrospective study of 40 cases.

    PubMed

    Gross, J-B; Gavanier, B; Belleville, R; Coudane, H; Mainard, D

    2017-10-01

    Proximal tibia fractures make up 1% of all fractures in adults. The fractures classified as Schatzker V and VI fractures can compromise knee structure and function. They are challenging to treat and often have complications. While plate fixation is the gold standard, the resulting infection rate has led us to favor external hybrid fixation. The aims of this study were to assess the radiographic and functional outcomes along with the complication rate when using this method and to compare them to historical plate fixation data. This was a retrospective study of 40 patients. The complications, quality of reduction, IKS, Lysholm and Rasmussen functional scores at the latest follow-up and factors affecting the functional outcome were evaluated. These parameters were compared to published results from plate fixation studies. The deep infection rate was 2.5%. The union rate was 80%. Satisfactory reduction was obtained in 70% of cases; however, 52% of patients had malunion. The mean IKS score was 73.74, the mean Rasmussen score was 22.85 and the mean Lysholm score was 75.53. Age, reduction at latest follow-up, mechanical axis and anteroposterior laxity had a significant effect on the functional outcome. Despite the malunion rate being higher than other studies, the functional outcomes were nearly identical based on the variables measured. There are several advantages associated with using a hybrid external fixator: shorter operative time, less bleeding, shorter hospital stays and lower infection rate. Hybrid external fixation is a reliable fracture fixation method that leads to satisfactory functional outcomes, while reducing the infection rate and allowing arthroplasty to be performed in the future if needed. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  10. A prospective study on 284 digital fractures of the hand.

    PubMed

    Pun, W K; Chow, S P; So, Y C; Luk, K D; Ip, F K; Chan, K C; Ngai, W K; Crosby, C; Ng, C

    1989-05-01

    We report a prospective study on 284 digital fractures of the hand in 235 patients. Management followed clear guidelines set out in a protocol. Important factors in the selection of the treatment method were, acceptable alignment, functional stability, and associated "significant" soft tissue injuries. "Functionally" stable fractures treated by free mobilization had satisfactory results. Unstable fractures treated by splints or Kirschner wire fixation produced unsatisfactory results. "Open fracture," "comminuted fracture," and "associated significant soft tissue injuries" were identified as unfavorable prognostic factors. The anatomic site of the fractures was not important in determining the final outcome. About 15% of the displaced fractures became functionally stable after closed reduction and their results were comparable with the undisplaced fractures. About 30% of the patients had various degrees of difficulty after they returned to work. About 14% of the patients eventually changed their jobs because of their residual disability.

  11. Acetabular cup position and risk of dislocation in primary total hip arthroplasty.

    PubMed

    Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik; Husted, Henrik; Gromov, Kirill

    2017-02-01

    Background and purpose - Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods - A systematic search of literature in the PubMed database was performed (January and February 2016) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results - 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced postoperative dislocation whereas others did not. The majority of articles could not identify a statistically significant difference between dislocating and non-dislocating THA with regard to mean angles of cup anteversion and inclination. Most of the articles that assessed cup placement within the Lewinnek safe zone did not show a statistically significant reduction in dislocation rate. Alternative target ranges have been proposed by several authors. Interpretation - The Lewinnek safe zone could not be justified. It is difficult to draw broad conclusions regarding a definitive target zone for cup positioning in THA, due to variability between studies and the likely multifactorial nature of THA dislocation. Future studies comparing cup positioning and dislocation rate should investigate surgical approach separately. Standardized tools for measurement of cup positioning should be implemented to allow comparison between studies.

  12. Computed tomography arthrography with traction in the human hip for three-dimensional reconstruction of cartilage and the acetabular labrum

    PubMed Central

    Henak, C.R.; Abraham, C.L.; Peters, C.L.; Sanders, R.K.; Weiss, J.A.; Anderson, A.E.

    2014-01-01

    AIM To develop and demonstrate the efficacy of a computed tomography arthrography (CTA) protocol for the hip that enables accurate three-dimensional reconstructions of cartilage and excellent visualization of the acetabular labrum. MATERIALS AND METHODS Ninety-three subjects were imaged (104 scans); 68 subjects with abnormal anatomy, 11 patients after periacetabular osteotomy surgery, and 25 subjects with normal anatomy. Fifteen to 25 ml of contrast agent diluted with lidocaine was injected using a lateral oblique approach. A Hare traction splint applied traction during CT. The association between traction force and intra-articular joint space was assessed qualitatively under fluoroscopy. Cartilage geometry was reconstructed from the CTA images for 30 subjects; the maximum joint space under traction was measured. RESULTS Using the Hare traction splint, the intra-articular space and boundaries of cartilage could be clearly delineated throughout the joint; the acetabular labrum was also visible. Dysplastic hips required less traction (~5 kg) than normal and retroverted hips required (>10 kg) to separate the cartilage. An increase in traction force produced a corresponding widening of the intra-articular joint space. Under traction, the maximum width of the intra-articular joint space during CT ranged from 0.98–6.7 mm (2.46 ± 1.16 mm). CONCLUSIONS When applied to subjects with normal and abnormal hip anatomy, the CTA protocol presented yields clear delineation of the cartilage and the acetabular labrum. Use of a Hare traction splint provides a simple, cost-effective method to widen the intra-articular joint space during CT, and provides flexibility to vary the traction as required. PMID:25070373

  13. Complications in Pediatric Facial Fractures

    PubMed Central

    Chao, Mimi T.; Losee, Joseph E.

    2009-01-01

    Despite recent advances in the diagnosis, treatment, and prevention of pediatric facial fractures, little has been published on the complications of these fractures. The existing literature is highly variable regarding both the definition and the reporting of adverse events. Although the incidence of pediatric facial fractures is relative low, they are strongly associated with other serious injuries. Both the fractures and their treatment may have long-term consequence on growth and development of the immature face. This article is a selective review of the literature on facial fracture complications with special emphasis on the complications unique to pediatric patients. We also present our classification system to evaluate adverse outcomes associated with pediatric facial fractures. Prospective, long-term studies are needed to fully understand and appreciate the complexity of treating children with facial fractures and determining the true incidence, subsequent growth, and nature of their complications. PMID:22110803

  14. Management of Complications of Distal Radius Fractures

    PubMed Central

    Chung, Kevin C.; Mathews, Alexandra L.

    2015-01-01

    Synopsis Treating a fracture of the distal radius may require the surgeon to make a difficult decision between surgical treatment and nonsurgical management. The use of surgical fixation has recently increased owing to complications associated with conservative treatment. However, conservative action may be necessary depending on certain patient factors. The treating surgeon must be aware of the possible complications associated with distal radius fracture treatments to prevent their occurrence. Prevention can be achieved with a proper understanding of the mechanism of these complications. This article discusses the most recent evidence on how to manage and prevent complications following a fracture of the distal radius. PMID:25934197

  15. Treatment of Pediatric Condylar Fractures: A 20-Year Experience.

    PubMed

    Ghasemzadeh, Ali; Mundinger, Gerhard S; Swanson, Edward W; Utria, Alan F; Dorafshar, Amir H

    2015-12-01

    The purpose of this study was to define patterns of injury and treatment for condylar and subcondylar fractures and evaluate short-term outcomes in the pediatric population. A retrospective chart review was performed on pediatric patients with mandibular condylar fractures who presented between 1990 and 2010. Computed tomographic imaging was reviewed for all patients to assess fracture characteristics. Mandibular fractures were codified using the Strasbourg Osteosynthesis Research Group and Lindahl classification methods. Sixty-four patients with 92 condylar fractures were identified. Of these patients, 29 had isolated condylar fracture and 35 had a condylar fracture associated with an additional mandibular arch fracture. The most common fracture patterns were diacapitular fracture in the Strasbourg Osteosynthesis Research Group system (n = 46) and vertical condylar head fracture in the Lindahl system (n = 14). Condylar fracture with additional mandibular arch fractures were treated with maxillomandibular fixation more often than patients with condylar fracture [n = 40 (74.1 percent) versus n = 14 (25.9 percent); p = 0.004]. No condylar fracture was treated in an open fashion. Forty-three patients returned for follow-up. The median follow-up period was 81 days (interquartile range, 35 to 294 days). Ten patients had complications (23.3 percent). The most common complication was malocclusion (n = 5). Nine of 10 patients with complications had condylar fracture with an additional mandibular arch fracture. Closed treatment of condylar fractures yields satisfactory results in pediatric patients. Pediatric patients with condylar fractures combined with additional arch fractures experience a higher rate of unfavorable outcomes.

  16. Treatment of Pediatric Condylar Fractures: A 20-Year Experience

    PubMed Central

    Ghasemzadeh, Ali; Mundinger, Gerhard S.; Swanson, Edward W.; Utria, Alan F.; Dorafshar, Amir H.

    2016-01-01

    Background The purpose of this study was to define patterns of injury and treatment for condylar and subcondylar fractures and evaluate short-term outcomes in the pediatric population. Methods A retrospective chart review was performed on pediatric patients with mandibular condylar fractures who presented between 1990 and 2010. Computed tomographic imaging was reviewed for all patients to assess fracture characteristics. Mandibular fractures were codified using the Strasbourg Osteosynthesis Research Group and Lindahl classification methods. Results Sixty-four patients with 92 condylar fractures were identified. Of these patients, 29 had isolated condylar fracture and 35 had a condylar fracture associated with an additional mandibular arch fracture. The most common fracture patterns were diacapitular fracture in the Strasbourg Osteosynthesis Research Group system (n = 46) and vertical condylar head fracture in the Lindahl system (n = 14). Condylar fracture with additional mandibular arch fractures were treated with maxillomandibular fixation more often than patients with condylar fracture [n = 40 (74.1 percent) versus n = 14 (25.9 percent); p = 0.004]. No condylar fracture was treated in an open fashion. Forty-three patients returned for follow-up. The median follow-up period was 81 days (interquartile range, 35 to 294 days). Ten patients had complications (23.3 percent). The most common complication was malocclusion (n = 5). Nine of 10 patients with complications had condylar fracture with an additional mandibular arch fracture. Conclusions Closed treatment of condylar fractures yields satisfactory results in pediatric patients. Pediatric patients with condylar fractures combined with additional arch fractures experience a higher rate of unfavorable outcomes. PMID:26595021

  17. A new technique for radiographic measurement of acetabular cup orientation.

    PubMed

    Derbyshire, Brian; Diggle, Peter J; Ingham, Christopher J; Macnair, Rory; Wimhurst, James; Jones, Henry Wynn

    2014-02-01

    Accurate radiographic measurement of acetabular cup orientation is required in order to assess susceptibility to impingement, dislocation, and edge loading wear. In this study, the accuracy and precision of a new radiographic cup orientation measurement system were assessed and compared to those of two commercially available systems. Two types of resurfacing hip prostheses and an uncemented prosthesis were assessed. Radiographic images of each prosthesis were created with the cup set at different, known angles of version and inclination in a measurement jig. The new system was the most accurate and precise and could repeatedly measure version and inclination to within a fraction of a degree. In addition it has a facility to distinguish cup retroversion from anteversion on anteroposterior radiographs. © 2013.

  18. Interventional MSK procedures: the hip.

    PubMed

    Dodré, Emilie; Lefebvre, Guillaume; Cockenpot, Eric; Chastanet, Patrick; Cotten, Anne

    2016-01-01

    Percutaneous musculoskeletal procedures are widely accepted as low invasive, highly effective, efficient and safe methods in a vast amount of hip pathologies either in diagnostic or in therapeutic management. Hip intra-articular injections are used for the symptomatic treatment of osteoarthritis. Peritendinous or intrabursal corticosteroid injections can be used for the symptomatic treatment of greater trochanteric pain syndrome and anterior iliopsoas impingement. In past decades, the role of interventional radiology has rapidly increased in metastatic disease, thanks to the development of many ablative techniques. Image-guided percutaneous ablation of skeletal metastases provides a minimally invasive treatment option that appears to be a safe and effective palliative treatment for localized painful lytic lesion. Methods of tumour destruction based on temperature, such as radiofrequency ablation (RFA) and cryotherapy, are performed for the management of musculoskeletal metastases. MR-guided focused ultrasound surgery provides a non-invasive alternative to these ablative methods. Cementoplasty is now widely used for pain management and consolidation of acetabular metastases and can be combined with RFA. RFA is also used to treat benign tumours, namely osteoid osteomas. New interventional procedures such as percutaneous screw fixation are also proposed to treat non-displaced or minimally displaced acetabular roof fractures.

  19. Wear versus Thickness and Other Features of 5-Mrad Crosslinked UHMWPE Acetabular Liners

    PubMed Central

    Shen, Fu-Wen; Lu, Zhen

    2010-01-01

    Background The low wear rates of crosslinked polyethylenes provide the potential to use larger diameters to resist dislocation. However, this requires the use of thinner liners in the acetabular component, with concern that higher contact stresses will increase wear, offsetting the benefits of the crosslinking. Questions/purposes We asked the following questions: Is the wear of conventional and crosslinked polyethylene liners affected by ball diameter, rigidity of backing, and liner thickness? Are the stresses in the liner affected by thickness? Methods Wear rates were measured in a hip simulator and stresses were calculated using finite element modeling. Results Without crosslinking, the wear rate was 4% to 10% greater with a 36-mm diameter than a 28-mm diameter. With crosslinking, wear was 9% lower with a 36-mm diameter without metal backing and 4% greater with metal backing. Reducing the thickness from 6 mm to 3 mm increased the contact stress by 46%, but the wear rate decreased by 19%. Conclusions The reduction in wear with 5 Mrad of crosslinking was not offset by increasing the diameter from 28 mm to 36 mm or by using a liner as thin as 3 mm. Clinical Relevance The results indicate, for a properly positioned 5-Mrad crosslinked acetabular component and within the range of dimensions evaluated, neither wear nor stresses in the polyethylene are limiting factors in the use of larger-diameter, thinner cups to resist dislocation. PMID:20848244

  20. Long-term results of uncemented alumina acetabular implants.

    PubMed

    Boehler, M; Knahr, K; Plenk, H; Walter, A; Salzer, M; Schreiber, V

    1994-01-01

    We report the clinical and tribological performance of 67 ceramic acetabular prostheses implanted between 1976 and 1979 without bone cement. They articulated with ceramic femoral heads mounted on mental femoral stems. After a mean elapsed period of 144 months, 59 sockets were radiographically stable but two showed early signs and six showed late signs of loosening. Four of the loose sockets have been revised. Histological analysis of the retrieved tissue showed a fibrous membrane around all the implants, with fibrocartilage in some. There was no bone ingrowth, and the fibrous membrane was up to 6 mm thick and infiltrated with lymphocytes, plasma cells, and macrophages. Intra- and extracellular birefringent wear particles were seen. Tribological analysis showed total wear rates in two retrieved alumina-on-alumina joints of 2.6 microns per year in a stable implant and 68 microns in a loose implant. Survival analysis showed a revision rate of 12.4% at 136 months.

  1. [Intramedullary stabilisation of clavicula fractures].

    PubMed

    Prokop, A; Schiffer, G; Jubel, A; Chmielnicki, M

    2013-10-01

    With an incidence of 64/100,000, clavicular shaft fractures are one of the most common fractures. Intramedullary fixation with Prevot nails was initially reported in the late 1990s. This procedure offers minimally invasive stabilization of the fracture, thus enabling immediate mobilization and rapid loading capacity. Using a case study, the positioning and procedure are demonstrated on video. The intramedullary implant accommodates the varying tension loading of the clavicle. This treatment is ideal for clavicular fractures with 2-3 fragments. Compared to patients treated conservatively, operated patients achieve more rapid and improved mobility. Employment disability is shorter, and malunion occurs less frequently. Georg Thieme Verlag KG Stuttgart · New York.

  2. Sports participation and radiographic findings of adolescents treated nonoperatively for displaced clavicle fractures.

    PubMed

    Robinson, Luke; Gargoum, Riyad; Auer, Ron; Nyland, John; Chan, Gilbert

    2015-07-01

    There is a relative paucity of high-level evidence that guides the treatment of displaced midshaft clavicle fractures in adolescents. Some use overhead sports or significant shortening as relative indications for surgical treatment, while others rarely consider operative intervention for these patients. The purpose of this study is to determine the effect of overhead sports participation and fracture shortening on subjective and objective outcomes after nonoperative treatment of displaced midshaft clavicle fractures in those aged 10-17 years. Using a radiographic database, adolescents with displaced clavicle fractures were identified and contacted over the phone. These subjects were invited to take part in the study in return for compensation. Radiographic measurements of dedicated clavicle films around the time of injury were performed, and a custom survey aimed at elucidating participation in overhead or contact sports was given. The Nottingham Clavicle Score (NCS) and the Constant Shoulder Score were obtained for each patient to provide both subjective and objective outcome data. Statistical Package for Social Science (SPSS) software (version 22, IBM) was used to compare radiographic and sports data to the outcome measures. Gender, age at the time of fracture, time since fracture, relative and absolute radiographic shortening, and hand dominance were all not significantly correlated with subjective or objective outcomes. Five patients (23%) reported not feeling happy with the appearance of their shoulder at the beach or at the pool. This group had statistically lower NCS results. Eleven of 22 participated in ≥6 months per year of overhead or contact sports; they did not have worse subjective or objective outcomes. Fracture shortening and sports participation do not have a significant impact in adolescents on outcomes after displaced midshaft clavicle fracture. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Is fusion necessary for thoracolumbar burst fracture treated with spinal fixation? A systematic review and meta-analysis.

    PubMed

    Diniz, Juliete M; Botelho, Ricardo V

    2017-11-01

    OBJECTIVE Thoracolumbar fractures account for 90% of spinal fractures, with the burst subtype corresponding to 20% of this total. Controversy regarding the best treatment for this condition remains. The traditional surgical approach, when indicated, involves spinal fixation and arthrodesis. Newer studies have brought the need for fusion associated with internal fixation into question. Not performing arthrodesis could reduce surgical time and intraoperative bleeding without affecting clinical and radiological outcomes. With this study, the authors aimed to assess the effect of fusion, adjuvant to internal fixation, on surgically treated thoracolumbar burst fractures. METHODS A search of the Medline and Cochrane Central Register of Controlled Trials databases was performed to identify randomized trials that compared the use and nonuse of arthrodesis in association with internal fixation for the treatment of thoracolumbar burst fractures. The search encompassed all data in these databases up to February 28, 2016. RESULTS Five randomized/quasi-randomized trials, which involved a total of 220 patients and an average follow-up time of 69.1 months, were included in this review. No significant difference between groups in the final scores of the visual analog pain scale or Low Back Outcome Scale was detected. Surgical time and blood loss were significantly lower in the group of patients who did not undergo fusion (p < 0.05). Among the evaluated radiological outcomes, greater mobility in the affected segment was found in the group of those who did not undergo fusion. No significant difference between groups in the degree of kyphosis correction, loss of kyphosis correction, or final angle of kyphosis was observed. CONCLUSIONS The data reviewed in this study suggest that the use of arthrodesis did not improve clinical outcomes, but it was associated with increased surgical time and higher intraoperative bleeding and did not promote significant improvement in radiological

  4. Management of patellar fracture with titanium cable cerclage

    PubMed Central

    Huang, Sheng-Li; Xue, Jian-Li; Gao, Zong-Qiang; Lan, Bin-Shang

    2017-01-01

    Abstract Early rehabilitation after surgery for patellar fracture is challenging. The purpose of this study was to evaluate the surgical outcome of titanium cable cerclage for patellar fracture in early functional activity. We reviewed a series of 24 patients treated at our hospital with titanium cable. Functional exercises were started early. Patients were followed up for at least 12 months. Fifteen were males and 9 were females. Fracture occurred in the right knee in 13 patients and in the left knee in 11 patients. The most common mode of injury involves a tumble. None of the patients presented with any postoperative complications. The management resulted in satisfactory outcomes. Titanium cable cerclage offers a new strategy in treating patellar fracture. PMID:29095314

  5. Compartment syndrome of the thigh complicating surgical treatment of ipsilateral femur and ankle fractures

    NASA Technical Reports Server (NTRS)

    Moore, M. R.; Garfin, S. R.; Hargens, A. R.

    1987-01-01

    A 26-year-old man presented with ipsilateral femur and ankle fractures. The patient was treated with interlocking nail of his femur fracture, followed by open reduction and internal fixation of his ankle fracture under tourniquet control. Postoperatively, the patient developed compartment syndrome of his thigh with elevated pressures, requiring decompressive fasciotomies. This case illustrates the possible complication of treating a femur fracture with intramedullary nailing and then immediately applying a tourniquet to treat an ipsilateral extremity fracture. Because of the complication with this patient, we feel the procedure should be staged, or a tourniquet should be avoided if possible.

  6. [Quality of life and job performance resulting from operatively treated tibial plateau fractures].

    PubMed

    Roßbach, B P; Faymonville, C; Müller, L P; Stützer, H; Isenberg, J

    2016-01-01

    The aim of this article is to present the functional results and the effect on quality of life of surgically treated tibial plateau fractures in physically active and working patients with multiple and serious injuries. In addition, the relationships between functional and radiological outcome were evaluated and compared with activity in daily and professional life. In all, 41 injured patients were followed up a mean of 47 months after surgical treatment and examined with radiological, functional, as well as quality of life score. In the radiological scoring, a mean value of 72 points (max 100 points) was achieved. In the activity score, there was an average of 63.5 points (max 100 points). When evaluating the health-related quality of life, an average score of 69.6 points was achieved. There was a significant relationship between radiological and activity scores and the radiological and life quality scores. Furthermore, the relationship between activity and quality of life scores was considered significant. Surgeon's influence on the functional outcome could be confirmed. The functional and the radiological results were moderate. Quality of life was permanently affected by the consequences of tibial plateau fracture in 12 patients; 11 patients were not re-employed. However, the quality of life was assessed as good or very good and 28 patients had returned to work. The quality of life was firmly linked to the radiological and functional parameters, which tended to be influenced by the quality of the primary surgical treatment when looking at the overall population.

  7. Migration characteristics and early clinical results of a novel-finned press-fit acetabular cup.

    PubMed

    Kaipel, Martin; Prenner, Anton; Bachl, Sebastian; Farr, Sebastian; Sinz, Günter

    2014-04-01

    Ana Nova® is a novel-finned press-fit acetabular cup which showed superior biomechanical characteristics in an experimental set-up. Using Einzel Bild Röntgen Analyse (EBRA) measurements should offer the opportunity to predict implant survival at an early stage. The purpose of this study was to assess migration and clinical outcome 2 years after total hip replacement by a novel-finned press-fit acetabular cup. In this study, migration and clinical results of the implant were prospectively assessed in 67 patients. Clinical outcome was assessed using the Harris hip score (HHS). Migration analyses were performed using the computer assisted EBRA system. Data were analyzed for normal distribution using the Kolmogorov-Smirnov test. Group comparisons were performed using the analysis of variance (ANOVA) test. P-values less than 0.05 were considered statistically significant. At 2 years after surgery, none of the implants needed revision and HHS increased from 39.7 up to 92.2. In contrast to the beneficial clinical outcome, 17 of 44 patients showed increased total migration ( 1 mm/2a). Adverse migration data in this study might predict aseptic loosening and decreased survival of the implant. According to previous studies, it is possible that this effect occurred because of limited accuracy of the EBRA system. In our opinion, migration analyses may not be recommended as a screening tool in a 2 year follow-up.

  8. Early predictive value of supine and upright X-ray films of odontoid fractures treated with halo-vest immobilization.

    PubMed

    Kim, David H; Vaccaro, Alexander R; Affonso, Jesse; Jenis, Louis; Hilibrand, Alan S; Albert, Todd J

    2008-01-01

    Although halo-vest immobilization remains a common form of treatment for type II odontoid fractures, nonunion and C1-2 instability may be the result in up to 20% to 40% of patients. Supine and upright lateral X-ray films may allow early identification of patients likely to fail halo-vest treatment and earlier surgical treatment with decreased morbidity from prolonged unsuccessful halo-vest immobilization. A prospective cohort study was performed. Twenty patients with type II odontoid fractures. Posttreatment nonunion and C1-2 instability as determined by plain X-ray films and computed tomography scan. Both supine and upright lateral X-ray films were obtained immediately after halo-vest application and at the 2-week, 6-week, and 3-month follow-up. Flexion-extension lateral X-ray films were obtained after halo-vest removal. Patients with nonunion or instability underwent computed tomography scan. Upright X-ray films were compared serially to identify loss of reduction. Pairs of supine and upright X-ray films were compared to measure any change in displacement or angulation upon transition from supine to upright position. Nonunion patients were compared with healed patients to determine any difference in fracture behavior based on serial supine and upright X-ray films. Twenty patients with type II odontoid fractures were identified during the study period. Three patients with multiple trauma underwent immediate surgical stabilization. Three elderly patients with nondisplaced fractures were treated in a cervical orthosis. Fourteen patients initiated and completed 3 months of halo-vest immobilization. After halo-vest removal, 4 of 14 patients (29%) showed radiographic nonunion or instability. In all 4 nonunion patients, supine and upright radiographs at 2 weeks revealed change in fracture angulation > or =5 degrees between the supine and upright positions. In three of these patients standard serial upright lateral X-ray films failed to identify any loss of reduction. In

  9. Different Surgical Approaches for Multiple Fractured Atrophic Mandibles

    PubMed Central

    Pereira, Felipe Ladeira; Gealh, Walter Cristiano; Barbosa, Carlos Eduardo Braga; Filho, Liogi Iwaki

    2011-01-01

    Atrophic edentulous mandible fractures in geriatric patients have low incidence but present several biological and biomechanical peculiarities that produce a nonunion rate of around 20%. Surgical extraoral approaches for internal fixation of these fractures can be transcervical or by one or two submandibular incisions. Two patients sustaining multiple fractures in atrophic edentulous mandible are presented: the first patient was 72-years-old, treated by two submandibular incisions, and the second was 81-years-old, treated by transcervical approach. We discuss the advantages and drawbacks of each approach and their indications according to the Luhr et al (1996) atrophy index. PMID:22379503

  10. Fracture of Fully-coated Femoral Stem after Primary Total Hip Arthroplasty for Nonunion of Intertrochanteric Fracture: A Case Report.

    PubMed

    Chun, Young Soo; Juh, Hyung Suk; Cho, Yoon Je; Rhyu, Kee Hyung

    2015-09-01

    Femoral stem fracture is an uncommon reason for the failure of total hip arthroplasty, with only 16 cases of fully coated stem fractures reported to date. Here we report a case in which a fully coated primary femoral stem fracture occurred after conversion to total hip arthroplasty for the non-union of an intertrochanteric fracture of the femur. Metallurgic evaluation of the etiology and mechanism revealed that the fracture was initiated by fatigue-related failure and completed by ductile failure on the posterior side of the fracture. Considering the recent trend of treating an intertrochanteric fracture with hip arthroplasty, possible stem failure should be considered, since most patients will have at least one of the known risk factors for stem fracture.

  11. Fracture of Fully-coated Femoral Stem after Primary Total Hip Arthroplasty for Nonunion of Intertrochanteric Fracture: A Case Report

    PubMed Central

    Chun, Young Soo; Juh, Hyung Suk; Cho, Yoon Je

    2015-01-01

    Femoral stem fracture is an uncommon reason for the failure of total hip arthroplasty, with only 16 cases of fully coated stem fractures reported to date. Here we report a case in which a fully coated primary femoral stem fracture occurred after conversion to total hip arthroplasty for the non-union of an intertrochanteric fracture of the femur. Metallurgic evaluation of the etiology and mechanism revealed that the fracture was initiated by fatigue-related failure and completed by ductile failure on the posterior side of the fracture. Considering the recent trend of treating an intertrochanteric fracture with hip arthroplasty, possible stem failure should be considered, since most patients will have at least one of the known risk factors for stem fracture. PMID:27536622

  12. Hybrid external fixation in the treatment of tibial pilon fractures: A retrospective analysis of 162 fractures.

    PubMed

    Galante, Vito N; Vicenti, Giovanni; Corina, Gianfranco; Mori, Claudio; Abate, Antonella; Picca, Girolamo; Conserva, Vito; Speciale, Domenico; Scialpi, Lorenzo; Tartaglia, Nicola; Caiaffa, Vincenzo; Moretti, Biagio

    2016-10-01

    To determine the efficacy of hybrid external fixation in the treatment of tibial pilon fractures. Retrospective, multicentre study. Adult patients with tibial pilon fractures treated with hybrid external fixation. Fracture reduction with ligamentotaxis and fixation with XCaliber hybrid external fixator. Fracture union, complications, functional outcome (Mazur Ankle Score). Union was obtained in 159 fractures at an average of 125days; there were three delayed unions and three non-unions. The most frequent complication was superficial pin-track infections (48), all of which responded to local wound care and antibiotics. There were no deep infections and no DVT. Only one fracture had loss of reduction that required frame revision. The overall functional scores were 91 (excellent) for AO/OTA type A fractures, 89 (good) for type B fractures, and 75 (satisfactory) for type C fractures. Hybrid external fixation is an effective method of stabilising tibial pilon fractures, particularly those with marked comminution. The minimally-invasive technique and stable fixation enable early mobilisation, with good functional results and minimal complications. Level IV Case series. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Foot and Ankle Stress Fractures in Athletes.

    PubMed

    Greaser, Michael C

    2016-10-01

    The incidence of stress fractures in the general athletic population is less than 1%, but may be as high as 15% in runners. Stress fractures of the foot and ankle account for almost half of bone stress injuries in athletes. These injuries occur because of repetitive submaximal stresses on the bone resulting in microfractures, which may coalesce to form complete fractures. Advanced imaging such as MRI and triple-phase bone scans is used to evaluate patients with suspected stress fracture. Low-risk stress fractures are typically treated with rest and protected weight bearing. High-stress fractures more often require surgical treatment. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. The experiences of physiotherapists treating people with dementia who fracture their hip.

    PubMed

    Hall, A J; Watkins, R; Lang, I A; Endacott, R; Goodwin, V A

    2017-04-20

    It is estimated that people with dementia are approximately three times more likely to fracture their hip than sex and age matched controls. A report by the Chartered Society of Physiotherapy found that this population have poor access to rehabilitation as inpatients and in the community. A recent scoping review found a paucity of research in this area, indeed there has been no qualitative research undertaken with physiotherapists. In order to address this evidence gap, the aim of this current study was to explore the experiences of physiotherapists treating this population. Semi-structured interviews with physiotherapists were undertaken in order to gain an in-depth understanding of how they manage this population. Physiotherapists were recruited from all over the UK and a purposive sampling strategy was employed. Thematic analysis was utilised. A total of 12 physiotherapists were interviewed, at which stage data saturation was reached as no new themes were emerging. The participants had a broad range of experience both in physical and mental health settings. Analysis identified three separate themes: challenges, "thinking outside the box" and realising potential. Physiotherapists felt significant pressures and challenges regarding many aspects of the management of this population. Mainly this was the result of pressures placed on them by guidelines and targets that may not be achievable or appropriate for those with dementia. The challenges and importance of risk taking was also highlighted for this population with an appreciation that standard treatment techniques may need adapting. "Rehabilitation potential" was highlighted as an important consideration, but challenging to determine. Interventions for the management of people with dementia and hip fracture need to consider that a traditional biomedical physiotherapy approach may not be the most appropriate approach to use with this population. However physiotherapists reported feeling pressurised to conform to

  15. Functional Improvement in Geriatric Hip Fractures: Does Vitamin D Deficiency Affect the Functional Outcome of Patients With Surgically Treated Intertrochanteric Hip Fractures.

    PubMed

    Seng, W R D; Belani, M H; Ramason, R; Naidu, G; Doshi, H K

    2015-09-01

    The "Integrated Care Pathway" for geriatric intertrochanteric (IT) fractures in Singapore's Tan Tock Seng Hospital has shown significant functional recovery in patients' activities of daily living. However, the influence of preoperative vitamin D on functional recovery remains equivocal. This retrospective study therefore aims to determine whether patients with preoperative vitamin D deficiency have poorer functional outcomes. A total of 171 patients who had surgical treatment for IT fractures were recruited in the study. They were categorized into group A (vitamin D deficient) and group B (normal vitamin D). Charlson Comorbidity Index (CCI) score and nutritional parameters including hemoglobin, albumin, and adjusted calcium levels on admission were recorded. The Modified Barthel Index (MBI) score was used to measure functional recovery at the following time intervals: at pre-fall, at discharge after surgery, at 6 months, and at 1-year follow-up. The mean age of both the groups (A: 79.7 years, n = 45; B: 83.0 years, n = 126) was statistically different (P < .05). However, the mean CCI (A: 9.42 and B: 10.13), hemoglobin (A: 12.4 and B 11.1), adjusted calcium (A: 2.39 and B: 2.38), and mean albumin (A: 33.6 and B: 33.0) of the groups were not significantly different. Furthermore, the MBI scores were not significantly different for both groups at preinjury (A: 91.5 and B: 89.4), at discharge (A: 55.2 and B: 58.9), at 6 months (A: 70.9 and B: 75.1), and at 1 year (A: 75.8 and B: 79.4). In our cohort, patients with vitamin D deficiency were younger. However, vitamin D deficiency at time of injury had no significant influence on functional recovery in patients with surgically treated hip fracture in our Integrated Care Pathway. In addition, patients who had a normal vitamin D levels had similar functional scores and improvement postoperatively and at 1 year (A: 82.8% and B: 88.9%).

  16. Overtreatment of displaced midshaft clavicle fractures

    PubMed Central

    Ban, Ilija; Nowak, Jan; Virtanen, Kaisa; Troelsen, Anders

    2016-01-01

    Background and purpose The best treatment for displaced clavicle fractures has been debated for decades. Operative treatment has become more common. However, several randomized trials comparing non-operative and operative treatment have not shown any compelling evidence in favor of surgery. We identified the preferred treatment of displaced midshaft clavicle fractures at public hospitals in 3 countries in Scandinavia. Patients and methods A purpose-made multiple-choice questionnaire in English was sent to all public hospitals in Denmark, Sweden, and Finland. This was addressed to the orthopedic surgeon responsible for treatment of clavicle fractures, and completed questionnaires were obtained from 85 of 118 hospitals. Results In the 3 countries, 69 of the 85 hospitals that responded would treat displaced clavicle fractures operatively. Clear criteria for treatment allocation were used at 58 of the hospitals, with the remaining 27 using individual assessment in collaboration with the patient. Precontoured locking plates were mostly used, placed either superiorly (64/85) or anteriorly (10/85). Interpretation Displaced midshaft clavicle fractures are mainly treated operatively in Sweden, Denmark, and Finland. This treatment is not supported by compelling evidence. PMID:27225678

  17. Etiology, distribution, treatment modalities and complications of maxillofacial fractures

    PubMed Central

    Pham-Dang, Nathalie; Barthélémy, Isabelle; Orliaguet, Thierry; Artola, Alain; Mondié, Jean M.

    2014-01-01

    Purpose: This study evaluated the trends and factors associated with maxillofacial fractures treated from 1997 to 2007 in the Oral and Maxillofacial Surgery Department of the Clermont-Ferrand University Hospital. Material and Methods: This study included 364 patients of which 82% were men and 45%, 20-29-years old. The etiology, anatomical distribution, treatment modality and complications of maxillofacial fractures were examined. Results: Overall, interpersonal violence, traffic accidents and falls were the most common mechanisms of injury. There was a decreasing trend in traffic accidents and increasing one in falls as a cause of fracture over the 11-years period of this study. Young male patients were preferentially victim of interpersonal violence and traffic accidents, while middle-aged ones were of falls and work-related accidents. Middle-aged female patients were preferentially victim of traffic accidents and interpersonal violence, while older ones were of falls. And the number of fractures per patient varied according to the mechanism of injury: low after work-related accidents and high after traffic accidents. About two-third of fractures involved the mandible. Most of these mandibular fractures were treated by osteosynthesis with or without intermaxillary fixation, with the proportion of the latter increasing over time. There were very few postoperative infections and only in mandible. Conclusions: Maxillofacial fractures predominantly occur in young men, due to interpersonal violence. There is nevertheless an increasing trend in falls as a cause of fracture, especially in female patients, consistent with the increasing trend in presentation of older people. Most maxillofacial fractures involve the mandible and there is an increasing trend in treating these fractures by osteosynthesis without intermaxillary fixation. Antibiotic prophylaxis associated with dental hygiene care can be indicated to prevent postoperative infections. Key words

  18. Epidemiology of forearm fractures in adults in Denmark: national age- and gender-specific incidence rates, ratio of forearm to hip fractures, and extent of surgical fracture repair in inpatients and outpatients.

    PubMed

    Abrahamsen, B; Jørgensen, N R; Schwarz, P

    2015-01-01

    National epidemiological studies of forearm fractures are scarce. We examined in- and outpatient rates in Denmark, including anatomical location, surgery, hospitalization ratio, recurrent fractures, and ratio of forearm to hip fractures. This may be useful for triangulation in countries with less detailed information. Rates were higher than previously estimated. Despite a significant contribution to the overall burden of osteoporotic, nonvertebral fractures, relatively little information is available about age- and gender-specific incidence rates for many countries including Denmark. We used national individual patient data on inpatient and outpatient treatment to calculate rates of forearm fractures, taking readmissions into account, with subtables for distal and proximal fractures. We also calculated ratios of forearm to hip fractures that may be useful when imputing forearm fracture rates from other administrative sources. In addition, we report the rates of hospital admission and the rates of surgical treatment, allowing readers to extrapolate from the number of admissions or surgical procedures to incidence rates, should their data sources be less comprehensive. Forearm fracture rates were 278 per 100,000 patient years in men aged 50+ and 1,110 per 100,000 in women aged 50+. The female to male incidence rate ratio was 4.0 for the age group 50+ but close to unity in persons aged 40 or under. Two thirds of patients were treated on an outpatient basis with little difference across age and gender strata. Four out of five fractures were treated conservatively. The rate of forearm fractures in Denmark was somewhat higher in both genders than recently imputed from hip fracture rates and were close to the rates previously reported in studies from Norway and Sweden. The rates of forearm fracture in Denmark are higher than previously estimated and very similar to the high risk reported from studies in Norway and Sweden.

  19. Fractures of the Femur. End Results*

    PubMed Central

    2008-01-01

    guidance [5]. We reproduce here an article in which Dr. Henderson reviewed 222 consecutive cases of femur fractures, 165 of which had been referred late because of complications of fractures treated elsewhere (clearly, by 1921, the Mayo Clinic was a referral source for others) [2]. Followup could not have been easy at a time when patients often came from a distance and travel was difficult, but it was described when available and in 40 of the 57 recent fractures, Henderson reported 87.5% were “cured.” Of the 165 old fractures, he was able to trace 143 (87%), a remarkable figure even today. He reported 90% of the femoral neck fractures were cured by various sorts of nonsurgical (6 patients) or surgical reconstructive (39 patients) means; 85% of the femoral shaft fractures were cured by either nonoperative (29 patients) or operative (69 patients) means. While he did not use the sort of outcomes we use today (the earliest orthopaedic outcome instruments were not introduced for four more decades: by Carroll B. Larson in 1963 [3] and William H. Harris in 1969 [1]), we can only presume Henderson meant union was achieved when patients were “cured” since nonunion or malunion would not have likely produced good results. That being the case, his rate of union was remarkable and would be enviable today in these sometimes difficult situations, attesting to his understanding of the individual situations and his skills. Melvin S. Henderson, MD is shown. Photograph is reproduced with permission and ©American Academy of Orthopaedic Surgeons. Fifty Years of Progress, 1983. References Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty: an end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51:737–755. Henderson MS. Fractures of the femur: end results. J Bone Joint Surg Am. 1921;3:520–528. Larson CB. Rating scale for hip disabilities. Clin Orthop Relat Res. 1963;31:85–93. Mostofi

  20. Restoration of the centre of rotation in primary total hip arthroplasty: the influence of acetabular floor depth and reaming technique.

    PubMed

    Meermans, G; Doorn, J Van; Kats, J-J

    2016-12-01

    One goal of total hip arthroplasty is to restore normal hip anatomy. The aim of this study was to compare displacement of the centre of rotation (COR) using a standard reaming technique with a technique in which the acetabulum was reamed immediately peripherally and referenced off the rim. In the first cohort the acetabulum was reamed to the floor followed by sequentially larger reamers. In the second cohort the acetabulum was only reamed peripherally, starting with a reamer the same size as the native femoral head. Anteroposterior pelvic radiographs were analysed for acetabular floor depth and vertical and horizontal position of the COR. Horizontally, the mean medial displacement of the COR was 0.8 mm (standard deviation (sd) 1.4) in the peripheral remaing group and 5.0 mm (sd 3.30) in the standard reaming group (p < 0.001). Vertically, the mean superior displacement of the COR was 0.7 mm (sd 1.3) in the peripheral reaming group and 3.7 mm (sd 2.6) in the standard reaming group (p < 0.001). In the standard reaming group, there was a strong correlation between the pre-operative acetabular floor depth and displacement of the COR (p < 0.001). Reaming the acetabulum to the floor can lead to significant displacement of the COR medially and superiorly. This displacement is related to the pre-operative acetabular floor depth and cannot always be compensated by using a high offset stem. Cite this article: Bone Joint J 2016;98-B:1597-603. ©2016 The British Editorial Society of Bone & Joint Surgery.