Sample records for achieve good accuracy

  1. How To Achieve Good Library Acoustics.

    ERIC Educational Resources Information Center

    Wiens, Janet

    2003-01-01

    Discusses how to create a good acoustical environment for college libraries, focusing on requirements related to the HVAC system and lighting, and noting the importance of good maintenance. A sidebar looks at how to design and achieve the most appropriate HVAC and lighting systems for optimum library acoustics. (SM)

  2. Photon caliper to achieve submillimeter positioning accuracy

    NASA Astrophysics Data System (ADS)

    Gallagher, Kyle J.; Wong, Jennifer; Zhang, Junan

    2017-09-01

    The purpose of this study was to demonstrate the feasibility of using a commercial two-dimensional (2D) detector array with an inherent detector spacing of 5 mm to achieve submillimeter accuracy in localizing the radiation isocenter. This was accomplished by delivering the Vernier ‘dose’ caliper to a 2D detector array where the nominal scale was the 2D detector array and the non-nominal Vernier scale was the radiation dose strips produced by the high-definition (HD) multileaf collimators (MLCs) of the linear accelerator. Because the HD MLC sequence was similar to the picket fence test, we called this procedure the Vernier picket fence (VPF) test. We confirmed the accuracy of the VPF test by offsetting the HD MLC bank by known increments and comparing the known offset with the VPF test result. The VPF test was able to determine the known offset within 0.02 mm. We also cross-validated the accuracy of the VPF test in an evaluation of couch hysteresis. This was done by using both the VPF test and the ExacTrac optical tracking system to evaluate the couch position. We showed that the VPF test was in agreement with the ExacTrac optical tracking system within a root-mean-square value of 0.07 mm for both the lateral and longitudinal directions. In conclusion, we demonstrated the VPF test can determine the offset between a 2D detector array and the radiation isocenter with submillimeter accuracy. Until now, no method to locate the radiation isocenter using a 2D detector array has been able to achieve such accuracy.

  3. Preliminary study of GPS orbit determination accuracy achievable from worldwide tracking data

    NASA Technical Reports Server (NTRS)

    Larden, D. R.; Bender, P. L.

    1982-01-01

    The improvement in the orbit accuracy if high accuracy tracking data from a substantially larger number of ground stations is available was investigated. Observations from 20 ground stations indicate that 20 cm or better accuracy can be achieved for the horizontal coordinates of the GPS satellites. With this accuracy, the contribution to the error budget for determining 1000 km baselines by GPS geodetic receivers would be only about 1 cm.

  4. Preliminary study of GPS orbit determination accuracy achievable from worldwide tracking data

    NASA Technical Reports Server (NTRS)

    Larden, D. R.; Bender, P. L.

    1983-01-01

    The improvement in the orbit accuracy if high accuracy tracking data from a substantially larger number of ground stations is available was investigated. Observations from 20 ground stations indicate that 20 cm or better accuracy can be achieved for the horizontal coordinates of the GPS satellites. With this accuracy, the contribution to the error budget for determining 1000 km baselines by GPS geodetic receivers would be only about 1 cm. Previously announced in STAR as N83-14605

  5. The Impossibility of Achieving Consistently Good Mental Health.

    ERIC Educational Resources Information Center

    Ellis, Albert

    1987-01-01

    People disturb themselves with irrational beliefs, some of which are obvious and blatant while others are subtle and tricky. The latter type make people more disturbed than do the former kind. Even when helped by the most efficient forms of psychotherapy, humans have difficulty achieving and maintaining good mental health. (Author/VM)

  6. Interactional Effects of Instructional Quality and Teacher Judgement Accuracy on Achievement.

    ERIC Educational Resources Information Center

    Helmke, Andreas; Schrader, Friedrich-Wilhelm

    1987-01-01

    Analysis of predictions of 32 teachers regarding 690 fifth-graders' scores on a mathematics achievement test found that the combination of high judgement accuracy with varied instructional techniques was particularly favorable to students in contrast to a combination of high diagnostic sensitivity with a low frequency of cues or individual…

  7. The relation between children's accuracy estimates of their physical competence and achievement-related characteristics.

    PubMed

    Weiss, M R; Horn, T S

    1990-09-01

    The relationship between perceptions of competence and control, achievement, and motivated behavior in youth sport has been a topic of considerable interest. The purpose of this study was to examine whether children who are under-, accurate, or overestimators of their physical competence differ in their achievement characteristics. Children (N = 133), 8 to 13 years of age, who were attending a summer sport program, completed a series of questionnaires designed to assess perceptions of competence and control, motivational orientation, and competitive trait anxiety. Measures of physical competence were obtained by teachers' ratings that paralleled the children's measure of perceived competence. Perceived competence and teachers' ratings were standardized by grade level, and an accuracy score was computed from the difference between these scores. Children were then categorized as underestimators, accurate raters, or overestimators according to upper and lower quartiles of this distribution. A 2 x 2 x 3 (age level by gender by accuracy) MANCOVA revealed a significant gender by accuracy interaction. Underestimating girls were lower in challenge motivation, higher in trait anxiety, and more external in their control perceptions than accurate or overestimators. Underestimating boys were higher in perceived unknown control than accurate and overestimating boys. It was concluded that children who seriously underestimate their perceived competence may be likely candidates for discontinuation of sport activities or low levels of physical achievement.

  8. Accuracy of Self-Reported College GPA: Gender-Moderated Differences by Achievement Level and Academic Self-Efficacy

    ERIC Educational Resources Information Center

    Caskie, Grace I. L.; Sutton, MaryAnn C.; Eckhardt, Amanda G.

    2014-01-01

    Assessments of college academic achievement tend to rely on self-reported GPA values, yet evidence is limited regarding the accuracy of those values. With a sample of 194 undergraduate college students, the present study examined whether accuracy of self-reported GPA differed based on level of academic performance or level of academic…

  9. Accuracy testing of steel and electric groundwater-level measuring tapes: Test method and in-service tape accuracy

    USGS Publications Warehouse

    Fulford, Janice M.; Clayton, Christopher S.

    2015-10-09

    The calibration device and proposed method were used to calibrate a sample of in-service USGS steel and electric groundwater tapes. The sample of in-service groundwater steel tapes were in relatively good condition. All steel tapes, except one, were accurate to ±0.01 ft per 100 ft over their entire length. One steel tape, which had obvious damage in the first hundred feet, was marginally outside the accuracy of ±0.01 ft per 100 ft by 0.001 ft. The sample of in-service groundwater-level electric tapes were in a range of conditions—from like new, with cosmetic damage, to nonfunctional. The in-service electric tapes did not meet the USGS accuracy recommendation of ±0.01 ft. In-service electric tapes, except for the nonfunctional tape, were accurate to about ±0.03 ft per 100 ft. A comparison of new with in-service electric tapes found that steel-core electric tapes maintained their length and accuracy better than electric tapes without a steel core. The in-service steel tapes could be used as is and achieve USGS accuracy recommendations for groundwater-level measurements. The in-service electric tapes require tape corrections to achieve USGS accuracy recommendations for groundwater-level measurement.

  10. Achieving DFT accuracy with a machine-learning interatomic potential: Thermomechanics and defects in bcc ferromagnetic iron

    NASA Astrophysics Data System (ADS)

    Dragoni, Daniele; Daff, Thomas D.; Csányi, Gábor; Marzari, Nicola

    2018-01-01

    We show that the Gaussian Approximation Potential (GAP) machine-learning framework can describe complex magnetic potential energy surfaces, taking ferromagnetic iron as a paradigmatic challenging case. The training database includes total energies, forces, and stresses obtained from density-functional theory in the generalized-gradient approximation, and comprises approximately 150,000 local atomic environments, ranging from pristine and defected bulk configurations to surfaces and generalized stacking faults with different crystallographic orientations. We find the structural, vibrational, and thermodynamic properties of the GAP model to be in excellent agreement with those obtained directly from first-principles electronic-structure calculations. There is good transferability to quantities, such as Peierls energy barriers, which are determined to a large extent by atomic configurations that were not part of the training set. We observe the benefit and the need of using highly converged electronic-structure calculations to sample a target potential energy surface. The end result is a systematically improvable potential that can achieve the same accuracy of density-functional theory calculations, but at a fraction of the computational cost.

  11. Achieving Climate Change Absolute Accuracy in Orbit

    NASA Technical Reports Server (NTRS)

    Wielicki, Bruce A.; Young, D. F.; Mlynczak, M. G.; Thome, K. J; Leroy, S.; Corliss, J.; Anderson, J. G.; Ao, C. O.; Bantges, R.; Best, F.; hide

    2013-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission will provide a calibration laboratory in orbit for the purpose of accurately measuring and attributing climate change. CLARREO measurements establish new climate change benchmarks with high absolute radiometric accuracy and high statistical confidence across a wide range of essential climate variables. CLARREO's inherently high absolute accuracy will be verified and traceable on orbit to Système Internationale (SI) units. The benchmarks established by CLARREO will be critical for assessing changes in the Earth system and climate model predictive capabilities for decades into the future as society works to meet the challenge of optimizing strategies for mitigating and adapting to climate change. The CLARREO benchmarks are derived from measurements of the Earth's thermal infrared spectrum (5-50 micron), the spectrum of solar radiation reflected by the Earth and its atmosphere (320-2300 nm), and radio occultation refractivity from which accurate temperature profiles are derived. The mission has the ability to provide new spectral fingerprints of climate change, as well as to provide the first orbiting radiometer with accuracy sufficient to serve as the reference transfer standard for other space sensors, in essence serving as a "NIST [National Institute of Standards and Technology] in orbit." CLARREO will greatly improve the accuracy and relevance of a wide range of space-borne instruments for decadal climate change. Finally, CLARREO has developed new metrics and methods for determining the accuracy requirements of climate observations for a wide range of climate variables and uncertainty sources. These methods should be useful for improving our understanding of observing requirements for most climate change observations.

  12. Achievable accuracy of hip screw holding power estimation by insertion torque measurement.

    PubMed

    Erani, Paolo; Baleani, Massimiliano

    2018-02-01

    To ensure stability of proximal femoral fractures, the hip screw must firmly engage into the femoral head. Some studies suggested that screw holding power into trabecular bone could be evaluated, intraoperatively, through measurement of screw insertion torque. However, those studies used synthetic bone, instead of trabecular bone, as host material or they did not evaluate accuracy of predictions. We determined prediction accuracy, also assessing the impact of screw design and host material. We measured, under highly-repeatable experimental conditions, disregarding clinical procedure complexities, insertion torque and pullout strength of four screw designs, both in 120 synthetic and 80 trabecular bone specimens of variable density. For both host materials, we calculated the root-mean-square error and the mean-absolute-percentage error of predictions based on the best fitting model of torque-pullout data, in both single-screw and merged dataset. Predictions based on screw-specific regression models were the most accurate. Host material impacts on prediction accuracy: the replacement of synthetic with trabecular bone decreased both root-mean-square errors, from 0.54 ÷ 0.76 kN to 0.21 ÷ 0.40 kN, and mean-absolute-percentage errors, from 14 ÷ 21% to 10 ÷ 12%. However, holding power predicted on low insertion torque remained inaccurate, with errors up to 40% for torques below 1 Nm. In poor-quality trabecular bone, tissue inhomogeneities likely affect pullout strength and insertion torque to different extents, limiting the predictive power of the latter. This bias decreases when the screw engages good-quality bone. Under this condition, predictions become more accurate although this result must be confirmed by close in-vitro simulation of the clinical procedure. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Achieving the same for less: improving mood depletes blood glucose for people with poor (but not good) emotion control.

    PubMed

    Niven, Karen; Totterdell, Peter; Miles, Eleanor; Webb, Thomas L; Sheeran, Paschal

    2013-01-01

    Previous studies have found that acts of self-control like emotion regulation deplete blood glucose levels. The present experiment investigated the hypothesis that the extent to which people's blood glucose levels decline during emotion regulation attempts is influenced by whether they believe themselves to be good or poor at emotion control. We found that although good and poor emotion regulators were equally able to achieve positive and negative moods, the blood glucose of poor emotion regulators was reduced after performing an affect-improving task, whereas the blood glucose of good emotion regulators remained unchanged. As evidence suggests that glucose is a limited energy resource upon which self-control relies, the implication is that good emotion regulators are able to achieve the same positive mood with less cost to their self-regulatory resource. Thus, depletion may not be an inevitable consequence of engaging in emotion regulation.

  14. Use of Selected Goodness-of-Fit Statistics to Assess the Accuracy of a Model of Henry Hagg Lake, Oregon

    NASA Astrophysics Data System (ADS)

    Rounds, S. A.; Sullivan, A. B.

    2004-12-01

    Assessing a model's ability to reproduce field data is a critical step in the modeling process. For any model, some method of determining goodness-of-fit to measured data is needed to aid in calibration and to evaluate model performance. Visualizations and graphical comparisons of model output are an excellent way to begin that assessment. At some point, however, model performance must be quantified. Goodness-of-fit statistics, including the mean error (ME), mean absolute error (MAE), root mean square error, and coefficient of determination, typically are used to measure model accuracy. Statistical tools such as the sign test or Wilcoxon test can be used to test for model bias. The runs test can detect phase errors in simulated time series. Each statistic is useful, but each has its limitations. None provides a complete quantification of model accuracy. In this study, a suite of goodness-of-fit statistics was applied to a model of Henry Hagg Lake in northwest Oregon. Hagg Lake is a man-made reservoir on Scoggins Creek, a tributary to the Tualatin River. Located on the west side of the Portland metropolitan area, the Tualatin Basin is home to more than 450,000 people. Stored water in Hagg Lake helps to meet the agricultural and municipal water needs of that population. Future water demands have caused water managers to plan for a potential expansion of Hagg Lake, doubling its storage to roughly 115,000 acre-feet. A model of the lake was constructed to evaluate the lake's water quality and estimate how that quality might change after raising the dam. The laterally averaged, two-dimensional, U.S. Army Corps of Engineers model CE-QUAL-W2 was used to construct the Hagg Lake model. Calibrated for the years 2000 and 2001 and confirmed with data from 2002 and 2003, modeled parameters included water temperature, ammonia, nitrate, phosphorus, algae, zooplankton, and dissolved oxygen. Several goodness-of-fit statistics were used to quantify model accuracy and bias. Model

  15. The accuracy of the ATLAS muon X-ray tomograph

    NASA Astrophysics Data System (ADS)

    Avramidou, R.; Berbiers, J.; Boudineau, C.; Dechelette, C.; Drakoulakos, D.; Fabjan, C.; Grau, S.; Gschwendtner, E.; Maugain, J.-M.; Rieder, H.; Rangod, S.; Rohrbach, F.; Sbrissa, E.; Sedykh, E.; Sedykh, I.; Smirnov, Y.; Vertogradov, L.; Vichou, I.

    2003-01-01

    A gigantic detector, the ATLAS project, is under construction at CERN for particle physics research at the Large Hadron Collider which is to be ready by 2006. An X-ray tomograph has been developed, designed and constructed at CERN in order to control the mechanical quality of the ATLAS muon chambers. We reached a measurement accuracy of 2 μm systematic and 2 μm statistical uncertainties in the horizontal and vertical directions in the working area 220 cm (horizontal)×60 cm (vertical). Here we describe in detail the fundamental approach of the basic principle chosen to achieve such good accuracy. In order to crosscheck our precision, key results of measurements are presented.

  16. The Effects of Individual or Group Guidelines on the Calibration Accuracy and Achievement of High School Biology Students

    ERIC Educational Resources Information Center

    Bol, Linda; Hacker, Douglas J.; Walck, Camilla C.; Nunnery, John A.

    2012-01-01

    A 2 x 2 factorial design was employed in a quasi-experiment to investigate the effects of guidelines in group or individual settings on the calibration accuracy and achievement of 82 high school biology students. Significant main effects indicated that calibration practice with guidelines and practice in group settings increased prediction and…

  17. Good Practices for Learning to Recognize Actions Using FV and VLAD.

    PubMed

    Wu, Jianxin; Zhang, Yu; Lin, Weiyao

    2016-12-01

    High dimensional representations such as Fisher vectors (FV) and vectors of locally aggregated descriptors (VLAD) have shown state-of-the-art accuracy for action recognition in videos. The high dimensionality, on the other hand, also causes computational difficulties when scaling up to large-scale video data. This paper makes three lines of contributions to learning to recognize actions using high dimensional representations. First, we reviewed several existing techniques that improve upon FV or VLAD in image classification, and performed extensive empirical evaluations to assess their applicability for action recognition. Our analyses of these empirical results show that normality and bimodality are essential to achieve high accuracy. Second, we proposed a new pooling strategy for VLAD and three simple, efficient, and effective transformations for both FV and VLAD. Both proposed methods have shown higher accuracy than the original FV/VLAD method in extensive evaluations. Third, we proposed and evaluated new feature selection and compression methods for the FV and VLAD representations. This strategy uses only 4% of the storage of the original representation, but achieves comparable or even higher accuracy. Based on these contributions, we recommend a set of good practices for action recognition in videos for practitioners in this field.

  18. Inattention in primary school is not good for your future school achievement-A pattern classification study.

    PubMed

    Lundervold, Astri J; Bøe, Tormod; Lundervold, Arvid

    2017-01-01

    Inattention in childhood is associated with academic problems later in life. The contribution of specific aspects of inattentive behaviour is, however, less known. We investigated feature importance of primary school teachers' reports on nine aspects of inattentive behaviour, gender and age in predicting future academic achievement. Primary school teachers of n = 2491 children (7-9 years) rated nine items reflecting different aspects of inattentive behaviour in 2002. A mean academic achievement score from the previous semester in high school (2012) was available for each youth from an official school register. All scores were at a categorical level. Feature importances were assessed by using multinominal logistic regression, classification and regression trees analysis, and a random forest algorithm. Finally, a comprehensive pattern classification procedure using k-fold cross-validation was implemented. Overall, inattention was rated as more severe in boys, who also obtained lower academic achievement scores in high school than girls. Problems related to sustained attention and distractibility were together with age and gender defined as the most important features to predict future achievement scores. Using these four features as input to a collection of classifiers employing k-fold cross-validation for prediction of academic achievement level, we obtained classification accuracy, precision and recall that were clearly better than chance levels. Primary school teachers' reports of problems related to sustained attention and distractibility were identified as the two most important features of inattentive behaviour predicting academic achievement in high school. Identification and follow-up procedures of primary school children showing these characteristics should be prioritised to prevent future academic failure.

  19. Estimating Achievable Accuracy for Global Imaging Spectroscopy Measurement of Non-Photosynthetic Vegetation Cover

    NASA Astrophysics Data System (ADS)

    Dennison, P. E.; Kokaly, R. F.; Daughtry, C. S. T.; Roberts, D. A.; Thompson, D. R.; Chambers, J. Q.; Nagler, P. L.; Okin, G. S.; Scarth, P.

    2016-12-01

    Terrestrial vegetation is dynamic, expressing seasonal, annual, and long-term changes in response to climate and disturbance. Phenology and disturbance (e.g. drought, insect attack, and wildfire) can result in a transition from photosynthesizing "green" vegetation to non-photosynthetic vegetation (NPV). NPV cover can include dead and senescent vegetation, plant litter, agricultural residues, and non-photosynthesizing stem tissue. NPV cover is poorly captured by conventional remote sensing vegetation indices, but it is readily separable from substrate cover based on spectral absorption features in the shortwave infrared. We will present past research motivating the need for global NPV measurements, establishing that mapping seasonal NPV cover is critical for improving our understanding of ecosystem function and carbon dynamics. We will also present new research that helps determine a best achievable accuracy for NPV cover estimation. To test the sensitivity of different NPV cover estimation methods, we simulated satellite imaging spectrometer data using field spectra collected over mixtures of NPV, green vegetation, and soil substrate. We incorporated atmospheric transmittance and modeled sensor noise to create simulated spectra with spectral resolutions ranging from 10 to 30 nm. We applied multiple methods of NPV estimation to the simulated spectra, including spectral indices, spectral feature analysis, multiple endmember spectral mixture analysis, and partial least squares regression, and compared the accuracy and bias of each method. These results prescribe sensor characteristics for an imaging spectrometer mission with NPV measurement capabilities, as well as a "Quantified Earth Science Objective" for global measurement of NPV cover. Copyright 2016, all rights reserved.

  20. 40 CFR 92.127 - Emission measurement accuracy.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...

  1. 40 CFR 92.127 - Emission measurement accuracy.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...

  2. 40 CFR 92.127 - Emission measurement accuracy.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...

  3. 40 CFR 92.127 - Emission measurement accuracy.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...

  4. 40 CFR 92.127 - Emission measurement accuracy.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...

  5. Communication Accuracy in Magazine Science Reporting.

    ERIC Educational Resources Information Center

    Borman, Susan Cray

    1978-01-01

    Evaluators with scientific expertise who analyzed the accuracy of popularized science news in mass circulation magazines found that the over-all accuracy of the magazine articles was good, and that the major problem was the omission of relevant information. (GW)

  6. Good Agreements Make Good Friends

    PubMed Central

    Han, The Anh; Pereira, Luís Moniz; Santos, Francisco C.; Lenaerts, Tom

    2013-01-01

    When starting a new collaborative endeavor, it pays to establish upfront how strongly your partner commits to the common goal and what compensation can be expected in case the collaboration is violated. Diverse examples in biological and social contexts have demonstrated the pervasiveness of making prior agreements on posterior compensations, suggesting that this behavior could have been shaped by natural selection. Here, we analyze the evolutionary relevance of such a commitment strategy and relate it to the costly punishment strategy, where no prior agreements are made. We show that when the cost of arranging a commitment deal lies within certain limits, substantial levels of cooperation can be achieved. Moreover, these levels are higher than that achieved by simple costly punishment, especially when one insists on sharing the arrangement cost. Not only do we show that good agreements make good friends, agreements based on shared costs result in even better outcomes. PMID:24045873

  7. Real-Time Tropospheric Product Establishment and Accuracy Assessment in China

    NASA Astrophysics Data System (ADS)

    Chen, M.; Guo, J.; Wu, J.; Song, W.; Zhang, D.

    2018-04-01

    Tropospheric delay has always been an important issue in Global Navigation Satellite System (GNSS) processing. Empirical tropospheric delay models are difficult to simulate complex and volatile atmospheric environments, resulting in poor accuracy of the empirical model and difficulty in meeting precise positioning demand. In recent years, some scholars proposed to establish real-time tropospheric product by using real-time or near-real-time GNSS observations in a small region, and achieved some good results. This paper uses real-time observing data of 210 Chinese national GNSS reference stations to estimate the tropospheric delay, and establishes ZWD grid model in the country wide. In order to analyze the influence of tropospheric grid product on wide-area real-time PPP, this paper compares the method of taking ZWD grid product as a constraint with the model correction method. The results show that the ZWD grid product estimated based on the national reference stations can improve PPP accuracy and convergence speed. The accuracy in the north (N), east (E) and up (U) direction increase by 31.8 %,15.6 % and 38.3 %, respectively. As with the convergence speed, the accuracy of U direction experiences the most improvement.

  8. Good Schools: What Research Says about Improving Student Achievement.

    ERIC Educational Resources Information Center

    Hawley, Willis D.; And Others

    1985-01-01

    This journal, presented in monograph form, reviews research findings in order to identify elements that influence student academic achievement. Sections focus on effective teaching, effect of school leadership on achievement, schoolwide learning environment, learning resources, and parent involvement. An extensive bibliography is included. (DF)

  9. Accuracy versus transparency in pharmacoeconomic modelling: finding the right balance.

    PubMed

    Eddy, David M

    2006-01-01

    As modellers push to make their models more accurate, the ability of others to understand the models can decrease, causing the models to lose transparency. When this type of conflict between accuracy and transparency occurs, the question arises, "Where do we want to operate on that spectrum?" This paper argues that in such cases we should give absolute priority to accuracy: push for whatever degree of accuracy is needed to answer the question being asked, try to maximise transparency within that constraint, and find other ways to replace what we wanted to get from transparency. There are several reasons. The fundamental purpose of a model is to help us get the right answer to a question and, by any measure, the expected value of a model is proportional to its accuracy. Ironically, we use transparency as a way to judge accuracy. But transparency is not a very powerful or useful way to do this. It rarely enables us to actually replicate the model's results and, even if we could, replication would not tell us the model's accuracy. Transparency rarely provides even face validity; from the content expert's perspective, the simplifications that modellers have to make usually raise more questions than they answer. Transparency does enable modellers to alert users to weaknesses in their models, but that can be achieved simply by listing the model's limitations and does not get us any closer to real accuracy. Sensitivity analysis tests the importance of uncertainty about the variables in a model, but does not tell us about the variables that were omitted or the structure of the model. What people really want to know is whether a model actually works. Transparency by itself can't answer this; only demonstrations that the model accurately calculates or predicts real events can. Rigorous simulations of clinical trials are a good place to start. This is the type of empirical validation we need to provide if the potential of mathematical models in pharmacoeconomics is to be

  10. Phase noise in pulsed Doppler lidar and limitations on achievable single-shot velocity accuracy

    NASA Technical Reports Server (NTRS)

    Mcnicholl, P.; Alejandro, S.

    1992-01-01

    The smaller sampling volumes afforded by Doppler lidars compared to radars allows for spatial resolutions at and below some sheer and turbulence wind structure scale sizes. This has brought new emphasis on achieving the optimum product of wind velocity and range resolutions. Several recent studies have considered the effects of amplitude noise, reduction algorithms, and possible hardware related signal artifacts on obtainable velocity accuracy. We discuss here the limitation on this accuracy resulting from the incoherent nature and finite temporal extent of backscatter from aerosols. For a lidar return from a hard (or slab) target, the phase of the intermediate frequency (IF) signal is random and the total return energy fluctuates from shot to shot due to speckle; however, the offset from the transmitted frequency is determinable with an accuracy subject only to instrumental effects and the signal to noise ratio (SNR), the noise being determined by the LO power in the shot noise limited regime. This is not the case for a return from a media extending over a range on the order of or greater than the spatial extent of the transmitted pulse, such as from atmospheric aerosols. In this case, the phase of the IF signal will exhibit a temporal random walk like behavior. It will be uncorrelated over times greater than the pulse duration as the transmitted pulse samples non-overlapping volumes of scattering centers. Frequency analysis of the IF signal in a window similar to the transmitted pulse envelope will therefore show shot-to-shot frequency deviations on the order of the inverse pulse duration reflecting the random phase rate variations. Like speckle, these deviations arise from the incoherent nature of the scattering process and diminish if the IF signal is averaged over times greater than a single range resolution cell (here the pulse duration). Apart from limiting the high SNR performance of a Doppler lidar, this shot-to-shot variance in velocity estimates has a

  11. Spacecraft attitude determination accuracy from mission experience

    NASA Technical Reports Server (NTRS)

    Brasoveanu, D.; Hashmall, J.

    1994-01-01

    This paper summarizes a compilation of attitude determination accuracies attained by a number of satellites supported by the Goddard Space Flight Center Flight Dynamics Facility. The compilation is designed to assist future mission planners in choosing and placing attitude hardware and selecting the attitude determination algorithms needed to achieve given accuracy requirements. The major goal of the compilation is to indicate realistic accuracies achievable using a given sensor complement based on mission experience. It is expected that the use of actual spacecraft experience will make the study especially useful for mission design. A general description of factors influencing spacecraft attitude accuracy is presented. These factors include determination algorithms, inertial reference unit characteristics, and error sources that can affect measurement accuracy. Possible techniques for mitigating errors are also included. Brief mission descriptions are presented with the attitude accuracies attained, grouped by the sensor pairs used in attitude determination. The accuracies for inactive missions represent a compendium of missions report results, and those for active missions represent measurements of attitude residuals. Both three-axis and spin stabilized missions are included. Special emphasis is given to high-accuracy sensor pairs, such as two fixed-head star trackers (FHST's) and fine Sun sensor plus FHST. Brief descriptions of sensor design and mode of operation are included. Also included are brief mission descriptions and plots summarizing the attitude accuracy attained using various sensor complements.

  12. The achievement of good chemical status: an impossible mission for local water managers?

    NASA Astrophysics Data System (ADS)

    La Jeunesse, Isabelle; Jadas-Hécart, Alain; Landry, David

    2017-04-01

    The European Water Framework Directive (2000) required to achieve good ecological and chemical status in surface waters of the EU Member States in 2015. For pesticides, this means ensuring that concentrations in rivers do not exceed 0.1 μg/L per molecule and 0.5 µg/L for the sum of the concentrations of the different molecules found. At national scale, EcoPhyto plan (2008) aimed to reduce pesticide use by 50% within 10. This plan has been revised and postponed to 2025 as observed pesticide use is varying between years and concentrations in river did not decrease as expected. Although vineyards cover a small percentage of agricultural land surfaces, they contribute to 20% of national pesticide use. The presence of pesticides in rivers surrounding wine territories is therefore a current environmental concern. Thus, the recovery of the water quality requires local action programs to reduce pesticide contamination in rivers. The Layon catchment comprises 13% of vineyard. It is therefore subject to an action program led by the local water committee: the SAGE Layon-Aubance-Louet. Its goal is to ensure pesticide concentrations are reduced to 1 µg/L in 2018 and 0.5 µg/L in 2027. In this context, one of the actions of the SAGE, with the assistance of the University of Angers, addresses the study of peaks in pesticide concentrations during runoff events in a small catchment covered by vineyards. Between 2009 and 2016, one of the two farmers has converted to organic farming with consequent decreases in pesticides input to the case study which thus complied with the EcoPhyto objectives. Results demonstrate first a peak intensity of pesticides in runoff waters in relation with the date of application with a decrease of concentrations during time after the treatment and second a relation between peaks of SPM and pesticides. Transfer of pesticides in this catchment is strongly linked to runoff. Thus, even if the increase of grass surface within vineyard improves the soil

  13. A promising tool to achieve chemical accuracy for density functional theory calculations on Y-NO homolysis bond dissociation energies.

    PubMed

    Li, Hong Zhi; Hu, Li Hong; Tao, Wei; Gao, Ting; Li, Hui; Lu, Ying Hua; Su, Zhong Min

    2012-01-01

    A DFT-SOFM-RBFNN method is proposed to improve the accuracy of DFT calculations on Y-NO (Y = C, N, O, S) homolysis bond dissociation energies (BDE) by combining density functional theory (DFT) and artificial intelligence/machine learning methods, which consist of self-organizing feature mapping neural networks (SOFMNN) and radial basis function neural networks (RBFNN). A descriptor refinement step including SOFMNN clustering analysis and correlation analysis is implemented. The SOFMNN clustering analysis is applied to classify descriptors, and the representative descriptors in the groups are selected as neural network inputs according to their closeness to the experimental values through correlation analysis. Redundant descriptors and intuitively biased choices of descriptors can be avoided by this newly introduced step. Using RBFNN calculation with the selected descriptors, chemical accuracy (≤1 kcal·mol(-1)) is achieved for all 92 calculated organic Y-NO homolysis BDE calculated by DFT-B3LYP, and the mean absolute deviations (MADs) of the B3LYP/6-31G(d) and B3LYP/STO-3G methods are reduced from 4.45 and 10.53 kcal·mol(-1) to 0.15 and 0.18 kcal·mol(-1), respectively. The improved results for the minimal basis set STO-3G reach the same accuracy as those of 6-31G(d), and thus B3LYP calculation with the minimal basis set is recommended to be used for minimizing the computational cost and to expand the applications to large molecular systems. Further extrapolation tests are performed with six molecules (two containing Si-NO bonds and two containing fluorine), and the accuracy of the tests was within 1 kcal·mol(-1). This study shows that DFT-SOFM-RBFNN is an efficient and highly accurate method for Y-NO homolysis BDE. The method may be used as a tool to design new NO carrier molecules.

  14. Finding common ground to achieve a "good death": family physicians working with substitute decision-makers of dying patients. A qualitative grounded theory study.

    PubMed

    Tan, Amy; Manca, Donna

    2013-01-22

    Substitute decision-makers are integral to the care of dying patients and make many healthcare decisions for patients. Unfortunately, conflict between physicians and surrogate decision-makers is not uncommon in end-of-life care and this could contribute to a "bad death" experience for the patient and family. We aim to describe Canadian family physicians' experiences of conflict with substitute decision-makers of dying patients to identify factors that may facilitate or hinder the end-of-life decision-making process. This insight will help determine how to best manage these complex situations, ultimately improving the overall care of dying patients. Grounded Theory methodology was used with semi-structured interviews of family physicians in Edmonton, Canada, who experienced conflict with substitute decision-makers of dying patients. Purposeful sampling included maximum variation and theoretical sampling strategies. Interviews were audio-taped, and transcribed verbatim. Transcripts, field notes and memos were coded using the constant-comparative method to identify key concepts until saturation was achieved and a theoretical framework emerged. Eleven family physicians with a range of 3 to 40 years in clinical practice participated.The family physicians expressed a desire to achieve a "good death" and described their role in positively influencing the experience of death.Finding Common Ground to Achieve a "Good Death" for the Patient emerged as an important process which includes 1) Building Mutual Trust and Rapport through identifying key players and delivering manageable amounts of information, 2) Understanding One Another through active listening and ultimately, and 3) Making Informed, Shared Decisions. Facilitators and barriers to achieving Common Ground were identified. Barriers were linked to conflict. The inability to resolve an overt conflict may lead to an impasse at any point. A process for Resolving an Impasse is described. A novel framework for developing

  15. Going GLP: Conducting Toxicology Studies in Compliance with Good Laboratory Practices.

    PubMed

    Carroll, Erica Eggers

    2016-01-01

    Good laboratory practice standards are US federal regulations enacted as part of the Federal Insecticide, Fungicide, and Rodenticide Act (40 CFR Part 160), the Toxic Substance Control Act (40 CFR Part 792), and the Good Laboratory Practice for Nonclinical Laboratory Studies (21 CFR Part 58) to support protection of public health in the areas of pesticides, chemicals, and drug investigations in response to allegations of inaccurate data acquisition. Essentially, good laboratory practices (GLPs) are a system of management controls for nonclinical research studies involving animals to ensure the uniformity, consistency, reliability, reproducibility, quality, and integrity of data collected as part of chemical (including pharmaceuticals) tests, from in vitro through acute to chronic toxicity tests. The GLPs were established in the United States in 1978 as a result of the Industrial Bio-Test Laboratory scandal which led to congressional hearings and actions to prevent fraudulent data reporting and collection. Although the establishment of infrastructure for GLPs compliance is labor-intensive and time-consuming, achievement and maintenance of GLP compliance ensures the accuracy of the data collected from each study, which is critical for defending results, advancing science, and protecting human and animal health. This article describes how and why those in the US Army Medical Department responsible for protecting the public health of US Army and other military personnel made the policy decision to have its toxicology laboratory achieve complete compliance with GLP standards, the first such among US Army laboratories. The challenges faced and how they were overcome are detailed.

  16. Finding common ground to achieve a “good death”: family physicians working with substitute decision-makers of dying patients. A qualitative grounded theory study

    PubMed Central

    2013-01-01

    Background Substitute decision-makers are integral to the care of dying patients and make many healthcare decisions for patients. Unfortunately, conflict between physicians and surrogate decision-makers is not uncommon in end-of-life care and this could contribute to a “bad death” experience for the patient and family. We aim to describe Canadian family physicians’ experiences of conflict with substitute decision-makers of dying patients to identify factors that may facilitate or hinder the end-of-life decision-making process. This insight will help determine how to best manage these complex situations, ultimately improving the overall care of dying patients. Methods Grounded Theory methodology was used with semi-structured interviews of family physicians in Edmonton, Canada, who experienced conflict with substitute decision-makers of dying patients. Purposeful sampling included maximum variation and theoretical sampling strategies. Interviews were audio-taped, and transcribed verbatim. Transcripts, field notes and memos were coded using the constant-comparative method to identify key concepts until saturation was achieved and a theoretical framework emerged. Results Eleven family physicians with a range of 3 to 40 years in clinical practice participated. The family physicians expressed a desire to achieve a “good death” and described their role in positively influencing the experience of death. Finding Common Ground to Achieve a “Good Death” for the Patient emerged as an important process which includes 1) Building Mutual Trust and Rapport through identifying key players and delivering manageable amounts of information, 2) Understanding One Another through active listening and ultimately, and 3) Making Informed, Shared Decisions. Facilitators and barriers to achieving Common Ground were identified. Barriers were linked to conflict. The inability to resolve an overt conflict may lead to an impasse at any point. A process for Resolving an Impasse is

  17. A Promising Tool to Achieve Chemical Accuracy for Density Functional Theory Calculations on Y-NO Homolysis Bond Dissociation Energies

    PubMed Central

    Li, Hong Zhi; Hu, Li Hong; Tao, Wei; Gao, Ting; Li, Hui; Lu, Ying Hua; Su, Zhong Min

    2012-01-01

    A DFT-SOFM-RBFNN method is proposed to improve the accuracy of DFT calculations on Y-NO (Y = C, N, O, S) homolysis bond dissociation energies (BDE) by combining density functional theory (DFT) and artificial intelligence/machine learning methods, which consist of self-organizing feature mapping neural networks (SOFMNN) and radial basis function neural networks (RBFNN). A descriptor refinement step including SOFMNN clustering analysis and correlation analysis is implemented. The SOFMNN clustering analysis is applied to classify descriptors, and the representative descriptors in the groups are selected as neural network inputs according to their closeness to the experimental values through correlation analysis. Redundant descriptors and intuitively biased choices of descriptors can be avoided by this newly introduced step. Using RBFNN calculation with the selected descriptors, chemical accuracy (≤1 kcal·mol−1) is achieved for all 92 calculated organic Y-NO homolysis BDE calculated by DFT-B3LYP, and the mean absolute deviations (MADs) of the B3LYP/6-31G(d) and B3LYP/STO-3G methods are reduced from 4.45 and 10.53 kcal·mol−1 to 0.15 and 0.18 kcal·mol−1, respectively. The improved results for the minimal basis set STO-3G reach the same accuracy as those of 6-31G(d), and thus B3LYP calculation with the minimal basis set is recommended to be used for minimizing the computational cost and to expand the applications to large molecular systems. Further extrapolation tests are performed with six molecules (two containing Si-NO bonds and two containing fluorine), and the accuracy of the tests was within 1 kcal·mol−1. This study shows that DFT-SOFM-RBFNN is an efficient and highly accurate method for Y-NO homolysis BDE. The method may be used as a tool to design new NO carrier molecules. PMID:22942689

  18. 40 CFR 89.310 - Analyzer accuracy and specifications.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... to § 89.323. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates... generally not be used. (2) Some high resolution read-out systems, such as computers, data loggers, and so..., using good engineering judgement, below 15 percent of full scale are made to ensure the accuracy of the...

  19. 40 CFR 89.310 - Analyzer accuracy and specifications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... to § 89.323. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates... generally not be used. (2) Some high resolution read-out systems, such as computers, data loggers, and so..., using good engineering judgement, below 15 percent of full scale are made to ensure the accuracy of the...

  20. 40 CFR 89.310 - Analyzer accuracy and specifications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... to § 89.323. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates... generally not be used. (2) Some high resolution read-out systems, such as computers, data loggers, and so..., using good engineering judgement, below 15 percent of full scale are made to ensure the accuracy of the...

  1. 40 CFR 89.310 - Analyzer accuracy and specifications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... to § 89.323. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates... generally not be used. (2) Some high resolution read-out systems, such as computers, data loggers, and so..., using good engineering judgement, below 15 percent of full scale are made to ensure the accuracy of the...

  2. 40 CFR 89.310 - Analyzer accuracy and specifications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... to § 89.323. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates... generally not be used. (2) Some high resolution read-out systems, such as computers, data loggers, and so..., using good engineering judgement, below 15 percent of full scale are made to ensure the accuracy of the...

  3. Achieving accuracy in first-principles calculations at extreme temperature and pressure

    NASA Astrophysics Data System (ADS)

    Mattsson, Ann; Wills, John

    2013-06-01

    First-principles calculations are increasingly used to provide EOS data at pressures and temperatures where experimental data is difficult or impossible to obtain. The lack of experimental data, however, also precludes validation of the calculations in those regimes. Factors influencing the accuracy of first-principles data include theoretical approximations, and computational approximations used in implementing and solving the underlying equations. The first category includes approximate exchange-correlation functionals and wave equations simplifying the Dirac equation. In the second category are, e.g., basis completeness and pseudo-potentials. While the first category is extremely hard to assess without experimental data, inaccuracies of the second type should be well controlled. We are using two rather different electronic structure methods (VASP and RSPt) to make explicit the requirements for accuracy of the second type. We will discuss the VASP Projector Augmented Wave potentials, with examples for Li and Mo. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  4. The Upper and Lower Bounds of the Prediction Accuracies of Ensemble Methods for Binary Classification

    PubMed Central

    Wang, Xueyi; Davidson, Nicholas J.

    2011-01-01

    Ensemble methods have been widely used to improve prediction accuracy over individual classifiers. In this paper, we achieve a few results about the prediction accuracies of ensemble methods for binary classification that are missed or misinterpreted in previous literature. First we show the upper and lower bounds of the prediction accuracies (i.e. the best and worst possible prediction accuracies) of ensemble methods. Next we show that an ensemble method can achieve > 0.5 prediction accuracy, while individual classifiers have < 0.5 prediction accuracies. Furthermore, for individual classifiers with different prediction accuracies, the average of the individual accuracies determines the upper and lower bounds. We perform two experiments to verify the results and show that it is hard to achieve the upper and lower bounds accuracies by random individual classifiers and better algorithms need to be developed. PMID:21853162

  5. Assessing and Ensuring GOES-R Magnetometer Accuracy

    NASA Technical Reports Server (NTRS)

    Kronenwetter, Jeffrey; Carter, Delano R.; Todirita, Monica; Chu, Donald

    2016-01-01

    The GOES-R magnetometer accuracy requirement is 1.7 nanoteslas (nT). During quiet times (100 nT), accuracy is defined as absolute mean plus 3 sigma. During storms (300 nT), accuracy is defined as absolute mean plus 2 sigma. To achieve this, the sensor itself has better than 1 nT accuracy. Because zero offset and scale factor drift over time, it is also necessary to perform annual calibration maneuvers. To predict performance, we used covariance analysis and attempted to corroborate it with simulations. Although not perfect, the two generally agree and show the expected behaviors. With the annual calibration regimen, these predictions suggest that the magnetometers will meet their accuracy requirements.

  6. Life Satisfaction among Highly Achieving Students in Hong Kong: Do Gratitude and the "Good-Enough Mindset" Add to the Contribution of Perfectionism in Prediction?

    ERIC Educational Resources Information Center

    Chan, David W.

    2012-01-01

    This study investigated whether gratitude and the "good-enough mindset" added to the contribution of perfectionism in predicting life satisfaction in 245 Chinese highly achieving students in Hong Kong. Participants completed self-report questionnaires that included scales on life satisfaction, positive and negative perfectionism…

  7. Good and Bad Public Prose.

    ERIC Educational Resources Information Center

    Cockburn, Stewart

    1969-01-01

    The basic requirements of all good prose are clarity, accuracy, brevity, and simplicity. Especially in public prose--in which the meaning is the crux of the article or speech--concise, vigorous English demands a minimum of adjectives, a maximum use of the active voice, nouns carefully chosen, a logical argument with no labored or obscure points,…

  8. Continuous Glucose Monitoring and Trend Accuracy

    PubMed Central

    Gottlieb, Rebecca; Le Compte, Aaron; Chase, J. Geoffrey

    2014-01-01

    Continuous glucose monitoring (CGM) devices are being increasingly used to monitor glycemia in people with diabetes. One advantage with CGM is the ability to monitor the trend of sensor glucose (SG) over time. However, there are few metrics available for assessing the trend accuracy of CGM devices. The aim of this study was to develop an easy to interpret tool for assessing trend accuracy of CGM data. SG data from CGM were compared to hourly blood glucose (BG) measurements and trend accuracy was quantified using the dot product. Trend accuracy results are displayed on the Trend Compass, which depicts trend accuracy as a function of BG. A trend performance table and Trend Index (TI) metric are also proposed. The Trend Compass was tested using simulated CGM data with varying levels of error and variability, as well as real clinical CGM data. The results show that the Trend Compass is an effective tool for differentiating good trend accuracy from poor trend accuracy, independent of glycemic variability. Furthermore, the real clinical data show that the Trend Compass assesses trend accuracy independent of point bias error. Finally, the importance of assessing trend accuracy as a function of BG level is highlighted in a case example of low and falling BG data, with corresponding rising SG data. This study developed a simple to use tool for quantifying trend accuracy. The resulting trend accuracy is easily interpreted on the Trend Compass plot, and if required, performance table and TI metric. PMID:24876437

  9. Spinal intra-operative three-dimensional navigation with infra-red tool tracking: correlation between clinical and absolute engineering accuracy

    NASA Astrophysics Data System (ADS)

    Guha, Daipayan; Jakubovic, Raphael; Gupta, Shaurya; Yang, Victor X. D.

    2017-02-01

    Computer-assisted navigation (CAN) may guide spinal surgeries, reliably reducing screw breach rates. Definitions of screw breach, if reported, vary widely across studies. Absolute quantitative error is theoretically a more precise and generalizable metric of navigation accuracy, but has been computed variably and reported in fewer than 25% of clinical studies of CAN-guided pedicle screw accuracy. We reviewed a prospectively-collected series of 209 pedicle screws placed with CAN guidance to characterize the correlation between clinical pedicle screw accuracy, based on postoperative imaging, and absolute quantitative navigation accuracy. We found that acceptable screw accuracy was achieved for significantly fewer screws based on 2mm grade vs. Heary grade, particularly in the lumbar spine. Inter-rater agreement was good for the Heary classification and moderate for the 2mm grade, significantly greater among radiologists than surgeon raters. Mean absolute translational/angular accuracies were 1.75mm/3.13° and 1.20mm/3.64° in the axial and sagittal planes, respectively. There was no correlation between clinical and absolute navigation accuracy, in part because surgeons appear to compensate for perceived translational navigation error by adjusting screw medialization angle. Future studies of navigation accuracy should therefore report absolute translational and angular errors. Clinical screw grades based on post-operative imaging, if reported, may be more reliable if performed in multiple by radiologist raters.

  10. Depreciation of public goods in spatial public goods games

    NASA Astrophysics Data System (ADS)

    Shi, Dong-Mei; Zhuang, Yong; Li, Yu-Jian; Wang, Bing-Hong

    2011-10-01

    In real situations, the value of public goods will be reduced or even lost because of external factors or for intrinsic reasons. In this work, we investigate the evolution of cooperation by considering the effect of depreciation of public goods in spatial public goods games on a square lattice. It is assumed that each individual gains full advantage if the number of the cooperators nc within a group centered on that individual equals or exceeds the critical mass (CM). Otherwise, there is depreciation of the public goods, which is realized by rescaling the multiplication factor r to (nc/CM)r. It is shown that the emergence of cooperation is remarkably promoted for CM > 1 even at small values of r, and a global cooperative level is achieved at an intermediate value of CM = 4 at a small r. We further study the effect of depreciation of public goods on different topologies of a regular lattice, and find that the system always reaches global cooperation at a moderate value of CM = G - 1 regardless of whether or not there exist overlapping triangle structures on the regular lattice, where G is the group size of the associated regular lattice.

  11. Accuracy Analysis of a Low-Cost Platform for Positioning and Navigation

    NASA Astrophysics Data System (ADS)

    Hofmann, S.; Kuntzsch, C.; Schulze, M. J.; Eggert, D.; Sester, M.

    2012-07-01

    This paper presents an accuracy analysis of a platform based on low-cost components for landmark-based navigation intended for research and teaching purposes. The proposed platform includes a LEGO MINDSTORMS NXT 2.0 kit, an Android-based Smartphone as well as a compact laser scanner Hokuyo URG-04LX. The robot is used in a small indoor environment, where GNSS is not available. Therefore, a landmark map was produced in advance, with the landmark positions provided to the robot. All steps of procedure to set up the platform are shown. The main focus of this paper is the reachable positioning accuracy, which was analyzed in this type of scenario depending on the accuracy of the reference landmarks and the directional and distance measuring accuracy of the laser scanner. Several experiments were carried out, demonstrating the practically achievable positioning accuracy. To evaluate the accuracy, ground truth was acquired using a total station. These results are compared to the theoretically achievable accuracies and the laser scanner's characteristics.

  12. A Conceptual Framework for Achieving Good Governance at Open and Distance Learning Institutions

    ERIC Educational Resources Information Center

    Khanna, Pankaj

    2017-01-01

    This paper describes a good governance architecture framework that would bring significant improvements in the overall working of open and distance learning institutions in a well-structured and systematic way. The good governance framework is articulated with seven basic principles which are performance, transparency, accountability,…

  13. Accuracy and Resolution in Micro-earthquake Tomographic Inversion Studies

    NASA Astrophysics Data System (ADS)

    Hutchings, L. J.; Ryan, J.

    2010-12-01

    Accuracy and resolution are complimentary properties necessary to interpret the results of earthquake location and tomography studies. Accuracy is the how close an answer is to the “real world”, and resolution is who small of node spacing or earthquake error ellipse one can achieve. We have modified SimulPS (Thurber, 1986) in several ways to provide a tool for evaluating accuracy and resolution of potential micro-earthquake networks. First, we provide synthetic travel times from synthetic three-dimensional geologic models and earthquake locations. We use this to calculate errors in earthquake location and velocity inversion results when we perturb these models and try to invert to obtain these models. We create as many stations as desired and can create a synthetic velocity model with any desired node spacing. We apply this study to SimulPS and TomoDD inversion studies. “Real” travel times are perturbed with noise and hypocenters are perturbed to replicate a starting location away from the “true” location, and inversion is performed by each program. We establish travel times with the pseudo-bending ray tracer and use the same ray tracer in the inversion codes. This, of course, limits our ability to test the accuracy of the ray tracer. We developed relationships for the accuracy and resolution expected as a function of the number of earthquakes and recording stations for typical tomographic inversion studies. Velocity grid spacing started at 1km, then was decreased to 500m, 100m, 50m and finally 10m to see if resolution with decent accuracy at that scale was possible. We considered accuracy to be good when we could invert a velocity model perturbed by 50% back to within 5% of the original model, and resolution to be the size of the grid spacing. We found that 100 m resolution could obtained by using 120 stations with 500 events, bu this is our current limit. The limiting factors are the size of computers needed for the large arrays in the inversion and a

  14. Psychoticism and disruptive behavior can be also good predictors of school achievement.

    PubMed

    Flores-Mendoza, Carmen; Widaman, Keith; Mansur-Alves, Marcela; Bacelar, Tatiane Dias; Saldanha, Renata

    2013-01-01

    The relations of Gf (Standard Progressive Matrices Raven), Gc (verbal scale of Wechsler Intelligence Scale for Children-Third Version), personality dimensions (Eysenck Personality Questionnaire-Junior Version), and disruptive behavior (TDAH scale) with school achievement (measured by TDE test and PISA test) were investigated. Two samples of students (total N = 534) representing a broad range of socioeconomic status (SES) participated in this study. Path models were conducted. The results demonstrated that (1) in both samples no sex differences related to school achievement were found; (2) in the first sample, after controlling for age and SES differences, Gf and psychoticism predicted (.38 and -.13, respectively) school achievement (measured by TDE test); (3) in the second sample, after controlling for SES differences to which additional measures were administered, Gf and Gc positively predicted (.22 and .40, respectively) school achievement (measured by PISA test). In addition, psychoticism and disruptive behavior also predicted school performance (-.14 and -.28, respectively). Some theoretical and practical implications are discussed.

  15. Raising the Achievement of White Working Class Pupils: Good Practice in Schools

    ERIC Educational Resources Information Center

    Lewis, Kirstin; Demie, Feyisa

    2015-01-01

    This research identifies strategies that schools have used to raise achievement among white working class pupils in multiracial schools. The methodological approach comprises case studies of schools and focus group interviews to ascertain the views of teachers, parents and children about strategies that worked to raise achievement. The study…

  16. A synthetic visual plane algorithm for visibility computation in consideration of accuracy and efficiency

    NASA Astrophysics Data System (ADS)

    Yu, Jieqing; Wu, Lixin; Hu, Qingsong; Yan, Zhigang; Zhang, Shaoliang

    2017-12-01

    Visibility computation is of great interest to location optimization, environmental planning, ecology, and tourism. Many algorithms have been developed for visibility computation. In this paper, we propose a novel method of visibility computation, called synthetic visual plane (SVP), to achieve better performance with respect to efficiency, accuracy, or both. The method uses a global horizon, which is a synthesis of line-of-sight information of all nearer points, to determine the visibility of a point, which makes it an accurate visibility method. We used discretization of horizon to gain a good performance in efficiency. After discretization, the accuracy and efficiency of SVP depends on the scale of discretization (i.e., zone width). The method is more accurate at smaller zone widths, but this requires a longer operating time. Users must strike a balance between accuracy and efficiency at their discretion. According to our experiments, SVP is less accurate but more efficient than R2 if the zone width is set to one grid. However, SVP becomes more accurate than R2 when the zone width is set to 1/24 grid, while it continues to perform as fast or faster than R2. Although SVP performs worse than reference plane and depth map with respect to efficiency, it is superior in accuracy to these other two algorithms.

  17. Improving Speaking Accuracy through Awareness

    ERIC Educational Resources Information Center

    Dormer, Jan Edwards

    2013-01-01

    Increased English learner accuracy can be achieved by leading students through six stages of awareness. The first three awareness stages build up students' motivation to improve, and the second three provide learners with crucial input for change. The final result is "sustained language awareness," resulting in ongoing…

  18. Achieving Accuracy Requirements for Forest Biomass Mapping: A Data Fusion Method for Estimating Forest Biomass and LiDAR Sampling Error with Spaceborne Data

    NASA Technical Reports Server (NTRS)

    Montesano, P. M.; Cook, B. D.; Sun, G.; Simard, M.; Zhang, Z.; Nelson, R. F.; Ranson, K. J.; Lutchke, S.; Blair, J. B.

    2012-01-01

    The synergistic use of active and passive remote sensing (i.e., data fusion) demonstrates the ability of spaceborne light detection and ranging (LiDAR), synthetic aperture radar (SAR) and multispectral imagery for achieving the accuracy requirements of a global forest biomass mapping mission. This data fusion approach also provides a means to extend 3D information from discrete spaceborne LiDAR measurements of forest structure across scales much larger than that of the LiDAR footprint. For estimating biomass, these measurements mix a number of errors including those associated with LiDAR footprint sampling over regional - global extents. A general framework for mapping above ground live forest biomass (AGB) with a data fusion approach is presented and verified using data from NASA field campaigns near Howland, ME, USA, to assess AGB and LiDAR sampling errors across a regionally representative landscape. We combined SAR and Landsat-derived optical (passive optical) image data to identify forest patches, and used image and simulated spaceborne LiDAR data to compute AGB and estimate LiDAR sampling error for forest patches and 100m, 250m, 500m, and 1km grid cells. Forest patches were delineated with Landsat-derived data and airborne SAR imagery, and simulated spaceborne LiDAR (SSL) data were derived from orbit and cloud cover simulations and airborne data from NASA's Laser Vegetation Imaging Sensor (L VIS). At both the patch and grid scales, we evaluated differences in AGB estimation and sampling error from the combined use of LiDAR with both SAR and passive optical and with either SAR or passive optical alone. This data fusion approach demonstrates that incorporating forest patches into the AGB mapping framework can provide sub-grid forest information for coarser grid-level AGB reporting, and that combining simulated spaceborne LiDAR with SAR and passive optical data are most useful for estimating AGB when measurements from LiDAR are limited because they minimized

  19. Teachers' Judgements of Students' Foreign-Language Achievement

    ERIC Educational Resources Information Center

    Zhu, Mingjing; Urhahne, Detlef

    2015-01-01

    Numerous studies have been conducted on the accuracy of teacher judgement in different educational areas such as mathematics, language arts and reading. Teacher judgement of students' foreign-language achievement, however, has been rarely investigated. The study aimed to examine the accuracy of teacher judgement of students' foreign-language…

  20. Clinical evaluation and treatment accuracy in diabetic macular edema using navigated laser photocoagulator NAVILAS.

    PubMed

    Kozak, Igor; Oster, Stephen F; Cortes, Marco A; Dowell, Dennis; Hartmann, Kathrin; Kim, Jae Suk; Freeman, William R

    2011-06-01

    To evaluate the clinical use and accuracy of a new retinal navigating laser technology that integrates a scanning slit fundus camera system with fluorescein angiography (FA), color, red-free, and infrared imaging capabilities with a computer steerable therapeutic 532-nm laser. Interventional case series. Eighty-six eyes of 61 patients with diabetic retinopathy and macular edema treated by NAVILAS. The imaging included digital color fundus photographs and FA. The planning included graphically marking future treatment sites (microaneurysms for single-spot focal treatment and areas of diffuse leakage for grid pattern photocoagulation) on the acquired images. The preplanned treatment was visible and overlaid on the live fundus image during the actual photocoagulation. The NAVILAS automatically advances the aiming beam location from one planned treatment site to the next after each photocoagulation spot until all sites are treated. Aiming beam stabilization compensated for patient's eye movements. The pretreatment FA with the treatment plan was overlaid on top of the posttreatment color fundus images with the actual laser burns. This allowed treatment accuracy to be calculated. Independent observers evaluated the images to determine if the retinal opacification after treatment overlapped the targeted microaneurysm. Safety and accuracy of laser photocoagulation. The images were of very good quality compared with standard fundus cameras, allowing careful delineation of target areas on FA. Toggling from infrared, to monochromatic, to color view allowed evaluation and adjustment of burn intensity during treatment. There were no complications during or after photocoagulation treatment. An analysis of accuracy of 400 random focal targeted spots found that the NAVILAS achieved a microaneurysm hit rate of 92% when the placement of the treatment circle was centered by the operating surgeon on the microaneurysm. The accuracy for the control group analyzing 100 focal spots was

  1. Spatial accuracy of a simplified disaggregation method for traffic emissions applied in seven mid-sized Chilean cities

    NASA Astrophysics Data System (ADS)

    Ossés de Eicker, Margarita; Zah, Rainer; Triviño, Rubén; Hurni, Hans

    The spatial accuracy of top-down traffic emission inventory maps obtained with a simplified disaggregation method based on street density was assessed in seven mid-sized Chilean cities. Each top-down emission inventory map was compared against a reference, namely a more accurate bottom-up emission inventory map from the same study area. The comparison was carried out using a combination of numerical indicators and visual interpretation. Statistically significant differences were found between the seven cities with regard to the spatial accuracy of their top-down emission inventory maps. In compact cities with a simple street network and a single center, a good accuracy of the spatial distribution of emissions was achieved with correlation values>0.8 with respect to the bottom-up emission inventory of reference. In contrast, the simplified disaggregation method is not suitable for complex cities consisting of interconnected nuclei, resulting in correlation values<0.5. Although top-down disaggregation of traffic emissions generally exhibits low accuracy, the accuracy is significantly higher in compact cities and might be further improved by applying a correction factor for the city center. Therefore, the method can be used by local environmental authorities in cities with limited resources and with little knowledge on the pollution situation to get an overview on the spatial distribution of the emissions generated by traffic activities.

  2. Critical thinking and accuracy of nurses' diagnoses.

    PubMed

    Lunney, Margaret

    2003-01-01

    Interpretations of patient data are complex and diverse, contributing to a risk of low accuracy nursing diagnoses. This risk is confirmed in research findings that accuracy of nurses' diagnoses varied widely from high to low. Highly accurate diagnoses are essential, however, to guide nursing interventions for the achievement of positive health outcomes. Development of critical thinking abilities is likely to improve accuracy of nurses' diagnoses. New views of critical thinking serve as a basis for critical thinking in nursing. Seven cognitive skills and ten habits of mind are identified as dimensions of critical thinking for use in the diagnostic process. Application of the cognitive skills of critical thinking illustrates the importance of using critical thinking for accuracy of nurses' diagnoses. Ten strategies are proposed for self-development of critical thinking abilities.

  3. Weight Multispectral Reconstruction Strategy for Enhanced Reconstruction Accuracy and Stability With Cerenkov Luminescence Tomography.

    PubMed

    Hongbo Guo; Xiaowei He; Muhan Liu; Zeyu Zhang; Zhenhua Hu; Jie Tian

    2017-06-01

    Cerenkov luminescence tomography (CLT) provides a novel technique for 3-D noninvasive detection of radiopharmaceuticals in living subjects. However, because of the severe scattering of Cerenkov light, the reconstruction accuracy and stability of CLT is still unsatisfied. In this paper, a modified weight multispectral CLT (wmCLT) reconstruction strategy was developed which split the Cerenkov radiation spectrum into several sub-spectral bands and weighted the sub-spectral results to obtain the final result. To better evaluate the property of the wmCLT reconstruction strategy in terms of accuracy, stability and practicability, several numerical simulation experiments and in vivo experiments were conducted and the results obtained were compared with the traditional multispectral CLT (mCLT) and hybrid-spectral CLT (hCLT) reconstruction strategies. The numerical simulation results indicated that wmCLT strategy significantly improved the accuracy of Cerenkov source localization and intensity quantitation and exhibited good stability in suppressing noise in numerical simulation experiments. And the comparison of the results achieved from different in vivo experiments further indicated significant improvement of the wmCLT strategy in terms of the shape recovery of the bladder and the spatial resolution of imaging xenograft tumors. Overall the strategy reported here will facilitate the development of nuclear and optical molecular tomography in theoretical study.

  4. High accuracy in short ISS missions

    NASA Astrophysics Data System (ADS)

    Rüeger, J. M.

    1986-06-01

    Traditionally Inertial Surveying Systems ( ISS) are used for missions of 30 km to 100 km length. Today, a new type of ISS application is emanating from an increased need for survey control densification in urban areas often in connection with land information systems or cadastral surveys. The accuracy requirements of urban surveys are usually high. The loss in accuracy caused by the coordinate transfer between IMU and ground marks is investigated and an offsetting system based on electronic tacheometers is proposed. An offsetting system based on a Hewlett-Packard HP 3820A electronic tacheometer has been tested in Sydney (Australia) in connection with a vehicle mounted LITTON Auto-Surveyor System II. On missions over 750 m ( 8 stations, 25 minutes duration, 3.5 minute ZUPT intervals, mean offset distances 9 metres) accuracies of 37 mm (one sigma) in position and 8 mm in elevation were achieved. Some improvements to the LITTON Auto-Surveyor System II are suggested which would improve the accuracies even further.

  5. Magnetic resonance enterography has good inter-rater agreement and diagnostic accuracy for detecting inflammation in pediatric Crohn disease.

    PubMed

    Church, Peter C; Greer, Mary-Louise C; Cytter-Kuint, Ruth; Doria, Andrea S; Griffiths, Anne M; Turner, Dan; Walters, Thomas D; Feldman, Brian M

    2017-05-01

    Magnetic resonance enterography (MRE) is increasingly relied upon for noninvasive assessment of intestinal inflammation in Crohn disease. However very few studies have examined the diagnostic accuracy of individual MRE signs in children. We have created an MR-based multi-item measure of intestinal inflammation in children with Crohn disease - the Pediatric Inflammatory Crohn's MRE Index (PICMI). To inform item selection for this instrument, we explored the inter-rater agreement and diagnostic accuracy of individual MRE signs of inflammation in pediatric Crohn disease and compared our findings with the reference standards of the weighted Pediatric Crohn's Disease Activity Index (wPCDAI) and C-reactive protein (CRP). In this cross-sectional single-center study, MRE studies in 48 children with diagnosed Crohn disease (66% male, median age 15.5 years) were reviewed by two independent radiologists for the presence of 15 MRE signs of inflammation. Using kappa statistics we explored inter-rater agreement for each MRE sign across 10 anatomical segments of the gastrointestinal tract. We correlated MRE signs with the reference standards using correlation coefficients. Radiologists measured the length of inflamed bowel in each segment of the gastrointestinal tract. In each segment, MRE signs were scored as either binary (0-absent, 1-present), or ordinal (0-absent, 1-mild, 2-marked). These segmental scores were weighted by the length of involved bowel and were summed to produce a weighted score per patient for each MRE sign. Using a combination of wPCDAI≥12.5 and CRP≥5 to define active inflammation, we calculated area under the receiver operating characteristic curve (AUC) for each weighted MRE sign. Bowel wall enhancement, wall T2 hyperintensity, wall thickening and wall diffusion-weighted imaging (DWI) hyperintensity were most commonly identified. Inter-rater agreement was best for decreased motility and wall DWI hyperintensity (kappa≥0.64). Correlation between MRE

  6. Achieving accuracy in first-principles calculations for EOS: basis completeness at high temperatures

    NASA Astrophysics Data System (ADS)

    Wills, John; Mattsson, Ann

    2013-06-01

    First-principles electronic structure calculations can provide EOS data in regimes of pressure and temperature where accurate experimental data is difficult or impossible to obtain. This lack, however, also precludes validation of calculations in those regimes. Factors that influence the accuracy of first-principles data include (1) theoretical approximations and (2) computational approximations used in implementing and solving the underlying equations. In the first category are the approximate exchange/correlation functionals and approximate wave equations approximating the Dirac equation; in the second are basis completeness, series convergence, and truncation errors. We are using two rather different electronic structure methods (VASP and RSPt) to make definitive the requirements for accuracy of the second type, common to both. In this talk, we discuss requirements for converged calculation at high temperature and moderated pressure. At convergence we show that both methods give identical results. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  7. The Role of Pattern Goodness in the Reproduction of Backward Masked Patterns

    ERIC Educational Resources Information Center

    Bell, Herbert H.; Handel, Stephen

    1976-01-01

    The purpose of the present work was to investigate the relation between pattern goodness and accuracy of reproduction in backward masking. It may be hypothesized that good patterns, being easier to encode as wholes, will be reproduced more easily than poorer patterns. Four experiments were performed. (Author)

  8. Limits on the Accuracy of Linking. Research Report. ETS RR-10-22

    ERIC Educational Resources Information Center

    Haberman, Shelby J.

    2010-01-01

    Sampling errors limit the accuracy with which forms can be linked. Limitations on accuracy are especially important in testing programs in which a very large number of forms are employed. Standard inequalities in mathematical statistics may be used to establish lower bounds on the achievable inking accuracy. To illustrate results, a variety of…

  9. Accuracy assessment of fluoroscopy-transesophageal echocardiography registration

    NASA Astrophysics Data System (ADS)

    Lang, Pencilla; Seslija, Petar; Bainbridge, Daniel; Guiraudon, Gerard M.; Jones, Doug L.; Chu, Michael W.; Holdsworth, David W.; Peters, Terry M.

    2011-03-01

    This study assesses the accuracy of a new transesophageal (TEE) ultrasound (US) fluoroscopy registration technique designed to guide percutaneous aortic valve replacement. In this minimally invasive procedure, a valve is inserted into the aortic annulus via a catheter. Navigation and positioning of the valve is guided primarily by intra-operative fluoroscopy. Poor anatomical visualization of the aortic root region can result in incorrect positioning, leading to heart valve embolization, obstruction of the coronary ostia and acute kidney injury. The use of TEE US images to augment intra-operative fluoroscopy provides significant improvements to image-guidance. Registration is achieved using an image-based TEE probe tracking technique and US calibration. TEE probe tracking is accomplished using a single-perspective pose estimation algorithm. Pose estimation from a single image allows registration to be achieved using only images collected in standard OR workflow. Accuracy of this registration technique is assessed using three models: a point target phantom, a cadaveric porcine heart with implanted fiducials, and in-vivo porcine images. Results demonstrate that registration can be achieved with an RMS error of less than 1.5mm, which is within the clinical accuracy requirements of 5mm. US-fluoroscopy registration based on single-perspective pose estimation demonstrates promise as a method for providing guidance to percutaneous aortic valve replacement procedures. Future work will focus on real-time implementation and a visualization system that can be used in the operating room.

  10. Increasing Accuracy in Computed Inviscid Boundary Conditions

    NASA Technical Reports Server (NTRS)

    Dyson, Roger

    2004-01-01

    A technique has been devised to increase the accuracy of computational simulations of flows of inviscid fluids by increasing the accuracy with which surface boundary conditions are represented. This technique is expected to be especially beneficial for computational aeroacoustics, wherein it enables proper accounting, not only for acoustic waves, but also for vorticity and entropy waves, at surfaces. Heretofore, inviscid nonlinear surface boundary conditions have been limited to third-order accuracy in time for stationary surfaces and to first-order accuracy in time for moving surfaces. For steady-state calculations, it may be possible to achieve higher accuracy in space, but high accuracy in time is needed for efficient simulation of multiscale unsteady flow phenomena. The present technique is the first surface treatment that provides the needed high accuracy through proper accounting of higher-order time derivatives. The present technique is founded on a method known in art as the Hermitian modified solution approximation (MESA) scheme. This is because high time accuracy at a surface depends upon, among other things, correction of the spatial cross-derivatives of flow variables, and many of these cross-derivatives are included explicitly on the computational grid in the MESA scheme. (Alternatively, a related method other than the MESA scheme could be used, as long as the method involves consistent application of the effects of the cross-derivatives.) While the mathematical derivation of the present technique is too lengthy and complex to fit within the space available for this article, the technique itself can be characterized in relatively simple terms: The technique involves correction of surface-normal spatial pressure derivatives at a boundary surface to satisfy the governing equations and the boundary conditions and thereby achieve arbitrarily high orders of time accuracy in special cases. The boundary conditions can now include a potentially infinite number

  11. A method which can enhance the optical-centering accuracy

    NASA Astrophysics Data System (ADS)

    Zhang, Xue-min; Zhang, Xue-jun; Dai, Yi-dan; Yu, Tao; Duan, Jia-you; Li, Hua

    2014-09-01

    Optical alignment machining is an effective method to ensure the co-axiality of optical system. The co-axiality accuracy is determined by optical-centering accuracy of single optical unit, which is determined by the rotating accuracy of lathe and the optical-centering judgment accuracy. When the rotating accuracy of 0.2um can be achieved, the leading error can be ignored. An axis-determination tool which is based on the principle of auto-collimation can be used to determine the only position of centerscope is designed. The only position is the position where the optical axis of centerscope is coincided with the rotating axis of the lathe. Also a new optical-centering judgment method is presented. A system which includes the axis-determination tool and the new optical-centering judgment method can enhance the optical-centering accuracy to 0.003mm.

  12. Face recognition accuracy of forensic examiners, superrecognizers, and face recognition algorithms.

    PubMed

    Phillips, P Jonathon; Yates, Amy N; Hu, Ying; Hahn, Carina A; Noyes, Eilidh; Jackson, Kelsey; Cavazos, Jacqueline G; Jeckeln, Géraldine; Ranjan, Rajeev; Sankaranarayanan, Swami; Chen, Jun-Cheng; Castillo, Carlos D; Chellappa, Rama; White, David; O'Toole, Alice J

    2018-06-12

    Achieving the upper limits of face identification accuracy in forensic applications can minimize errors that have profound social and personal consequences. Although forensic examiners identify faces in these applications, systematic tests of their accuracy are rare. How can we achieve the most accurate face identification: using people and/or machines working alone or in collaboration? In a comprehensive comparison of face identification by humans and computers, we found that forensic facial examiners, facial reviewers, and superrecognizers were more accurate than fingerprint examiners and students on a challenging face identification test. Individual performance on the test varied widely. On the same test, four deep convolutional neural networks (DCNNs), developed between 2015 and 2017, identified faces within the range of human accuracy. Accuracy of the algorithms increased steadily over time, with the most recent DCNN scoring above the median of the forensic facial examiners. Using crowd-sourcing methods, we fused the judgments of multiple forensic facial examiners by averaging their rating-based identity judgments. Accuracy was substantially better for fused judgments than for individuals working alone. Fusion also served to stabilize performance, boosting the scores of lower-performing individuals and decreasing variability. Single forensic facial examiners fused with the best algorithm were more accurate than the combination of two examiners. Therefore, collaboration among humans and between humans and machines offers tangible benefits to face identification accuracy in important applications. These results offer an evidence-based roadmap for achieving the most accurate face identification possible. Copyright © 2018 the Author(s). Published by PNAS.

  13. HIV-1 tropism testing in subjects achieving undetectable HIV-1 RNA: diagnostic accuracy, viral evolution and compartmentalization.

    PubMed

    Pou, Christian; Codoñer, Francisco M; Thielen, Alexander; Bellido, Rocío; Pérez-Álvarez, Susana; Cabrera, Cecilia; Dalmau, Judith; Curriu, Marta; Lie, Yolanda; Noguera-Julian, Marc; Puig, Jordi; Martínez-Picado, Javier; Blanco, Julià; Coakley, Eoin; Däumer, Martin; Clotet, Bonaventura; Paredes, Roger

    2013-01-01

    Technically, HIV-1 tropism can be evaluated in plasma or peripheral blood mononuclear cells (PBMCs). However, only tropism testing of plasma HIV-1 has been validated as a tool to predict virological response to CCR5 antagonists in clinical trials. The preferable tropism testing strategy in subjects with undetectable HIV-1 viremia, in whom plasma tropism testing is not feasible, remains uncertain. We designed a proof-of-concept study including 30 chronically HIV-1-infected individuals who achieved HIV-1 RNA <50 copies/mL during at least 2 years after first-line ART initiation. First, we determined the diagnostic accuracy of 454 and population sequencing of gp120 V3-loops in plasma and PBMCs, as well as of MT-2 assays before ART initiation. The Enhanced Sensitivity Trofile Assay (ESTA) was used as the technical reference standard. 454 sequencing of plasma viruses provided the highest agreement with ESTA. The accuracy of 454 sequencing decreased in PBMCs due to reduced specificity. Population sequencing in plasma and PBMCs was slightly less accurate than plasma 454 sequencing, being less sensitive but more specific. MT-2 assays had low sensitivity but 100% specificity. Then, we used optimized 454 sequence data to investigate viral evolution in PBMCs during viremia suppression and only found evolution of R5 viruses in one subject. No de novo CXCR4-using HIV-1 production was observed over time. Finally, Slatkin-Maddison tests suggested that plasma and cell-associated V3 forms were sometimes compartmentalized. The absence of tropism shifts during viremia suppression suggests that, when available, testing of stored plasma samples is generally safe and informative, provided that HIV-1 suppression is maintained. Tropism testing in PBMCs may not necessarily produce equivalent biological results to plasma, because the structure of viral populations and the diagnostic performance of tropism assays may sometimes vary between compartments. Thereby, proviral DNA tropism testing

  14. Linear Discriminant Analysis Achieves High Classification Accuracy for the BOLD fMRI Response to Naturalistic Movie Stimuli

    PubMed Central

    Mandelkow, Hendrik; de Zwart, Jacco A.; Duyn, Jeff H.

    2016-01-01

    Naturalistic stimuli like movies evoke complex perceptual processes, which are of great interest in the study of human cognition by functional MRI (fMRI). However, conventional fMRI analysis based on statistical parametric mapping (SPM) and the general linear model (GLM) is hampered by a lack of accurate parametric models of the BOLD response to complex stimuli. In this situation, statistical machine-learning methods, a.k.a. multivariate pattern analysis (MVPA), have received growing attention for their ability to generate stimulus response models in a data-driven fashion. However, machine-learning methods typically require large amounts of training data as well as computational resources. In the past, this has largely limited their application to fMRI experiments involving small sets of stimulus categories and small regions of interest in the brain. By contrast, the present study compares several classification algorithms known as Nearest Neighbor (NN), Gaussian Naïve Bayes (GNB), and (regularized) Linear Discriminant Analysis (LDA) in terms of their classification accuracy in discriminating the global fMRI response patterns evoked by a large number of naturalistic visual stimuli presented as a movie. Results show that LDA regularized by principal component analysis (PCA) achieved high classification accuracies, above 90% on average for single fMRI volumes acquired 2 s apart during a 300 s movie (chance level 0.7% = 2 s/300 s). The largest source of classification errors were autocorrelations in the BOLD signal compounded by the similarity of consecutive stimuli. All classifiers performed best when given input features from a large region of interest comprising around 25% of the voxels that responded significantly to the visual stimulus. Consistent with this, the most informative principal components represented widespread distributions of co-activated brain regions that were similar between subjects and may represent functional networks. In light of these

  15. Female teachers' math anxiety affects girls' math achievement.

    PubMed

    Beilock, Sian L; Gunderson, Elizabeth A; Ramirez, Gerardo; Levine, Susan C

    2010-02-02

    People's fear and anxiety about doing math--over and above actual math ability--can be an impediment to their math achievement. We show that when the math-anxious individuals are female elementary school teachers, their math anxiety carries negative consequences for the math achievement of their female students. Early elementary school teachers in the United States are almost exclusively female (>90%), and we provide evidence that these female teachers' anxieties relate to girls' math achievement via girls' beliefs about who is good at math. First- and second-grade female teachers completed measures of math anxiety. The math achievement of the students in these teachers' classrooms was also assessed. There was no relation between a teacher's math anxiety and her students' math achievement at the beginning of the school year. By the school year's end, however, the more anxious teachers were about math, the more likely girls (but not boys) were to endorse the commonly held stereotype that "boys are good at math, and girls are good at reading" and the lower these girls' math achievement. Indeed, by the end of the school year, girls who endorsed this stereotype had significantly worse math achievement than girls who did not and than boys overall. In early elementary school, where the teachers are almost all female, teachers' math anxiety carries consequences for girls' math achievement by influencing girls' beliefs about who is good at math.

  16. Improving IMES Localization Accuracy by Integrating Dead Reckoning Information

    PubMed Central

    Fujii, Kenjiro; Arie, Hiroaki; Wang, Wei; Kaneko, Yuto; Sakamoto, Yoshihiro; Schmitz, Alexander; Sugano, Shigeki

    2016-01-01

    Indoor positioning remains an open problem, because it is difficult to achieve satisfactory accuracy within an indoor environment using current radio-based localization technology. In this study, we investigate the use of Indoor Messaging System (IMES) radio for high-accuracy indoor positioning. A hybrid positioning method combining IMES radio strength information and pedestrian dead reckoning information is proposed in order to improve IMES localization accuracy. For understanding the carrier noise ratio versus distance relation for IMES radio, the signal propagation of IMES radio is modeled and identified. Then, trilateration and extended Kalman filtering methods using the radio propagation model are developed for position estimation. These methods are evaluated through robot localization and pedestrian localization experiments. The experimental results show that the proposed hybrid positioning method achieved average estimation errors of 217 and 1846 mm in robot localization and pedestrian localization, respectively. In addition, in order to examine the reason for the positioning accuracy of pedestrian localization being much lower than that of robot localization, the influence of the human body on the radio propagation is experimentally evaluated. The result suggests that the influence of the human body can be modeled. PMID:26828492

  17. To address accuracy and precision using methods from analytical chemistry and computational physics.

    PubMed

    Kozmutza, Cornelia; Picó, Yolanda

    2009-04-01

    In this work the pesticides were determined by liquid chromatography-mass spectrometry (LC-MS). In present study the occurrence of imidacloprid in 343 samples of oranges, tangerines, date plum, and watermelons from Valencian Community (Spain) has been investigated. The nine additional pesticides were chosen as they have been recommended for orchard treatment together with imidacloprid. The Mulliken population analysis has been applied to present the charge distribution in imidacloprid. Partitioned energy terms and the virial ratios have been calculated for certain molecules entering in interaction. A new technique based on the comparison of the decomposed total energy terms at various configurations is demonstrated in this work. The interaction ability could be established correctly in the studied case. An attempt is also made in this work to address accuracy and precision. These quantities are well-known in experimental measurements. In case precise theoretical description is achieved for the contributing monomers and also for the interacting complex structure some properties of this latter system can be predicted to quite a good accuracy. Based on simple hypothetical considerations we estimate the impact of applying computations on reducing the amount of analytical work.

  18. COMPASS time synchronization and dissemination—Toward centimetre positioning accuracy

    NASA Astrophysics Data System (ADS)

    Wang, ZhengBo; Zhao, Lu; Wang, ShiGuang; Zhang, JianWei; Wang, Bo; Wang, LiJun

    2014-09-01

    In this paper we investigate methods to achieve highly accurate time synchronization among the satellites of the COMPASS global navigation satellite system (GNSS). Owing to the special design of COMPASS which implements several geo-stationary satellites (GEO), time synchronization can be highly accurate via microwave links between ground stations to the GEO satellites. Serving as space-borne relay stations, the GEO satellites can further disseminate time and frequency signals to other satellites such as the inclined geo-synchronous (IGSO) and mid-earth orbit (MEO) satellites within the system. It is shown that, because of the accuracy in clock synchronization, the theoretical accuracy of COMPASS positioning and navigation will surpass that of the GPS. In addition, the COMPASS system can function with its entire positioning, navigation, and time-dissemination services even without the ground link, thus making it much more robust and secure. We further show that time dissemination using the COMPASS-GEO satellites to earth-fixed stations can achieve very high accuracy, to reach 100 ps in time dissemination and 3 cm in positioning accuracy, respectively. In this paper, we also analyze two feasible synchronization plans. All special and general relativistic effects related to COMPASS clocks frequency and time shifts are given. We conclude that COMPASS can reach centimeter-level positioning accuracy and discuss potential applications.

  19. Story Goodness in Adolescents with Autism Spectrum Disorder (ASD) and in Optimal Outcomes from ASD

    ERIC Educational Resources Information Center

    Canfield, Allison R.; Eigsti, Inge-Marie; de Marchena, Ashley; Fein, Deborah

    2016-01-01

    Purpose: This study examined narrative quality of adolescents with autism spectrum disorder (ASD) using a well-studied "story goodness" coding system. Method: Narrative samples were analyzed for distinct aspects of story goodness and rated by naïve readers on dimensions of story goodness, accuracy, cohesiveness, and oddness. Adolescents…

  20. The Effects of Alcohol Intoxication on Accuracy and the Confidence–Accuracy Relationship in Photographic Simultaneous Line‐ups

    PubMed Central

    Colloff, Melissa F.; Karoğlu, Nilda; Zelek, Katarzyna; Ryder, Hannah; Humphries, Joyce E.; Takarangi, Melanie K.T.

    2017-01-01

    Summary Acute alcohol intoxication during encoding can impair subsequent identification accuracy, but results across studies have been inconsistent, with studies often finding no effect. Little is also known about how alcohol intoxication affects the identification confidence–accuracy relationship. We randomly assigned women (N = 153) to consume alcohol (dosed to achieve a 0.08% blood alcohol content) or tonic water, controlling for alcohol expectancy. Women then participated in an interactive hypothetical sexual assault scenario and, 24 hours or 7 days later, attempted to identify the assailant from a perpetrator present or a perpetrator absent simultaneous line‐up and reported their decision confidence. Overall, levels of identification accuracy were similar across the alcohol and tonic water groups. However, women who had consumed tonic water as opposed to alcohol identified the assailant with higher confidence on average. Further, calibration analyses suggested that confidence is predictive of accuracy regardless of alcohol consumption. The theoretical and applied implications of our results are discussed.© 2017 The Authors Applied Cognitive Psychology Published by John Wiley & Sons Ltd. PMID:28781426

  1. 40 CFR 86.1338-84 - Emission measurement accuracy.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... engineering practice dictates that exhaust emission sample analyzer readings below 15 percent of full scale... computers, data loggers, etc., can provide sufficient accuracy and resolution below 15 percent of full scale... spaced points, using good engineering judgement, below 15 percent of full scale are made to ensure the...

  2. 40 CFR 86.1338-84 - Emission measurement accuracy.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... engineering practice dictates that exhaust emission sample analyzer readings below 15 percent of full scale... computers, data loggers, etc., can provide sufficient accuracy and resolution below 15 percent of full scale... spaced points, using good engineering judgement, below 15 percent of full scale are made to ensure the...

  3. 40 CFR 86.1338-84 - Emission measurement accuracy.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... engineering practice dictates that exhaust emission sample analyzer readings below 15 percent of full scale... computers, data loggers, etc., can provide sufficient accuracy and resolution below 15 percent of full scale... spaced points, using good engineering judgement, below 15 percent of full scale are made to ensure the...

  4. 40 CFR 86.1338-84 - Emission measurement accuracy.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... engineering practice dictates that exhaust emission sample analyzer readings below 15 percent of full scale... computers, data loggers, etc., can provide sufficient accuracy and resolution below 15 percent of full scale... spaced points, using good engineering judgement, below 15 percent of full scale are made to ensure the...

  5. High-accuracy drilling with an image guided light weight robot: autonomous versus intuitive feed control.

    PubMed

    Tauscher, Sebastian; Fuchs, Alexander; Baier, Fabian; Kahrs, Lüder A; Ortmaier, Tobias

    2017-10-01

    Assistance of robotic systems in the operating room promises higher accuracy and, hence, demanding surgical interventions become realisable (e.g. the direct cochlear access). Additionally, an intuitive user interface is crucial for the use of robots in surgery. Torque sensors in the joints can be employed for intuitive interaction concepts. Regarding the accuracy, they lead to a lower structural stiffness and, thus, to an additional error source. The aim of this contribution is to examine, if an accuracy needed for demanding interventions can be achieved by such a system or not. Feasible accuracy results of the robot-assisted process depend on each work-flow step. This work focuses on the determination of the tool coordinate frame. A method for drill axis definition is implemented and analysed. Furthermore, a concept of admittance feed control is developed. This allows the user to control feeding along the planned path by applying a force to the robots structure. The accuracy is researched by drilling experiments with a PMMA phantom and artificial bone blocks. The described drill axis estimation process results in a high angular repeatability ([Formula: see text]). In the first set of drilling results, an accuracy of [Formula: see text] at entrance and [Formula: see text] at target point excluding imaging was achieved. With admittance feed control an accuracy of [Formula: see text] at target point was realised. In a third set twelve holes were drilled in artificial temporal bone phantoms including imaging. In this set-up an error of [Formula: see text] and [Formula: see text] was achieved. The results of conducted experiments show that accuracy requirements for demanding procedures such as the direct cochlear access can be fulfilled with compliant systems. Furthermore, it was shown that with the presented admittance feed control an accuracy of less then [Formula: see text] is achievable.

  6. Experimental studies of high-accuracy RFID localization with channel impairments

    NASA Astrophysics Data System (ADS)

    Pauls, Eric; Zhang, Yimin D.

    2015-05-01

    Radio frequency identification (RFID) systems present an incredibly cost-effective and easy-to-implement solution to close-range localization. One of the important applications of a passive RFID system is to determine the reader position through multilateration based on the estimated distances between the reader and multiple distributed reference tags obtained from, e.g., the received signal strength indicator (RSSI) readings. In practice, the achievable accuracy of passive RFID reader localization suffers from many factors, such as the distorted RSSI reading due to channel impairments in terms of the susceptibility to reader antenna patterns and multipath propagation. Previous studies have shown that the accuracy of passive RFID localization can be significantly improved by properly modeling and compensating for such channel impairments. The objective of this paper is to report experimental study results that validate the effectiveness of such approaches for high-accuracy RFID localization. We also examine a number of practical issues arising in the underlying problem that limit the accuracy of reader-tag distance measurements and, therefore, the estimated reader localization. These issues include the variations in tag radiation characteristics for similar tags, effects of tag orientations, and reader RSS quantization and measurement errors. As such, this paper reveals valuable insights of the issues and solutions toward achieving high-accuracy passive RFID localization.

  7. Efficient full-chip SRAF placement using machine learning for best accuracy and improved consistency

    NASA Astrophysics Data System (ADS)

    Wang, Shibing; Baron, Stanislas; Kachwala, Nishrin; Kallingal, Chidam; Sun, Dezheng; Shu, Vincent; Fong, Weichun; Li, Zero; Elsaid, Ahmad; Gao, Jin-Wei; Su, Jing; Ser, Jung-Hoon; Zhang, Quan; Chen, Been-Der; Howell, Rafael; Hsu, Stephen; Luo, Larry; Zou, Yi; Zhang, Gary; Lu, Yen-Wen; Cao, Yu

    2018-03-01

    Various computational approaches from rule-based to model-based methods exist to place Sub-Resolution Assist Features (SRAF) in order to increase process window for lithography. Each method has its advantages and drawbacks, and typically requires the user to make a trade-off between time of development, accuracy, consistency and cycle time. Rule-based methods, used since the 90 nm node, require long development time and struggle to achieve good process window performance for complex patterns. Heuristically driven, their development is often iterative and involves significant engineering time from multiple disciplines (Litho, OPC and DTCO). Model-based approaches have been widely adopted since the 20 nm node. While the development of model-driven placement methods is relatively straightforward, they often become computationally expensive when high accuracy is required. Furthermore these methods tend to yield less consistent SRAFs due to the nature of the approach: they rely on a model which is sensitive to the pattern placement on the native simulation grid, and can be impacted by such related grid dependency effects. Those undesirable effects tend to become stronger when more iterations or complexity are needed in the algorithm to achieve required accuracy. ASML Brion has developed a new SRAF placement technique on the Tachyon platform that is assisted by machine learning and significantly improves the accuracy of full chip SRAF placement while keeping consistency and runtime under control. A Deep Convolutional Neural Network (DCNN) is trained using the target wafer layout and corresponding Continuous Transmission Mask (CTM) images. These CTM images have been fully optimized using the Tachyon inverse mask optimization engine. The neural network generated SRAF guidance map is then used to place SRAF on full-chip. This is different from our existing full-chip MB-SRAF approach which utilizes a SRAF guidance map (SGM) of mask sensitivity to improve the contrast of

  8. Field Accuracy Test of Rpas Photogrammetry

    NASA Astrophysics Data System (ADS)

    Barry, P.; Coakley, R.

    2013-08-01

    Baseline Surveys Ltd is a company which specialises in the supply of accurate geospatial data, such as cadastral, topographic and engineering survey data to commercial and government bodies. Baseline Surveys Ltd invested in aerial drone photogrammetric technology and had a requirement to establish the spatial accuracy of the geographic data derived from our unmanned aerial vehicle (UAV) photogrammetry before marketing our new aerial mapping service. Having supplied the construction industry with survey data for over 20 years, we felt that is was crucial for our clients to clearly understand the accuracy of our photogrammetry so they can safely make informed spatial decisions, within the known accuracy limitations of our data. This information would also inform us on how and where UAV photogrammetry can be utilised. What we wanted to find out was the actual accuracy that can be reliably achieved using a UAV to collect data under field conditions throughout a 2 Ha site. We flew a UAV over the test area in a "lawnmower track" pattern with an 80% front and 80% side overlap; we placed 45 ground markers as check points and surveyed them in using network Real Time Kinematic Global Positioning System (RTK GPS). We specifically designed the ground markers to meet our accuracy needs. We established 10 separate ground markers as control points and inputted these into our photo modelling software, Agisoft PhotoScan. The remaining GPS coordinated check point data were added later in ArcMap to the completed orthomosaic and digital elevation model so we could accurately compare the UAV photogrammetry XYZ data with the RTK GPS XYZ data at highly reliable common points. The accuracy we achieved throughout the 45 check points was 95% reliably within 41 mm horizontally and 68 mm vertically and with an 11.7 mm ground sample distance taken from a flight altitude above ground level of 90 m.The area covered by one image was 70.2 m × 46.4 m, which equals 0.325 Ha. This finding has shown

  9. MUSCLE: multiple sequence alignment with high accuracy and high throughput.

    PubMed

    Edgar, Robert C

    2004-01-01

    We describe MUSCLE, a new computer program for creating multiple alignments of protein sequences. Elements of the algorithm include fast distance estimation using kmer counting, progressive alignment using a new profile function we call the log-expectation score, and refinement using tree-dependent restricted partitioning. The speed and accuracy of MUSCLE are compared with T-Coffee, MAFFT and CLUSTALW on four test sets of reference alignments: BAliBASE, SABmark, SMART and a new benchmark, PREFAB. MUSCLE achieves the highest, or joint highest, rank in accuracy on each of these sets. Without refinement, MUSCLE achieves average accuracy statistically indistinguishable from T-Coffee and MAFFT, and is the fastest of the tested methods for large numbers of sequences, aligning 5000 sequences of average length 350 in 7 min on a current desktop computer. The MUSCLE program, source code and PREFAB test data are freely available at http://www.drive5. com/muscle.

  10. The Effects of Student Characteristics on Teachers' Judgment Accuracy: Disentangling Ethnicity, Minority Status, and Achievement

    ERIC Educational Resources Information Center

    Kaiser, Johanna; Südkamp, Anna; Möller, Jens

    2017-01-01

    Teachers' judgments of students' academic achievement are not only affected by the achievement themselves but also by several other characteristics such as ethnicity, gender, and minority status. In real-life classrooms, achievement and further characteristics are often confounded. We disentangled achievement, ethnicity and minority status and…

  11. Genomic selection accuracies within and between environments and small breeding groups in white spruce.

    PubMed

    Beaulieu, Jean; Doerksen, Trevor K; MacKay, John; Rainville, André; Bousquet, Jean

    2014-12-02

    Genomic selection (GS) may improve selection response over conventional pedigree-based selection if markers capture more detailed information than pedigrees in recently domesticated tree species and/or make it more cost effective. Genomic prediction accuracies using 1748 trees and 6932 SNPs representative of as many distinct gene loci were determined for growth and wood traits in white spruce, within and between environments and breeding groups (BG), each with an effective size of Ne ≈ 20. Marker subsets were also tested. Model fits and/or cross-validation (CV) prediction accuracies for ridge regression (RR) and the least absolute shrinkage and selection operator models approached those of pedigree-based models. With strong relatedness between CV sets, prediction accuracies for RR within environment and BG were high for wood (r = 0.71-0.79) and moderately high for growth (r = 0.52-0.69) traits, in line with trends in heritabilities. For both classes of traits, these accuracies achieved between 83% and 92% of those obtained with phenotypes and pedigree information. Prediction into untested environments remained moderately high for wood (r ≥ 0.61) but dropped significantly for growth (r ≥ 0.24) traits, emphasizing the need to phenotype in all test environments and model genotype-by-environment interactions for growth traits. Removing relatedness between CV sets sharply decreased prediction accuracies for all traits and subpopulations, falling near zero between BGs with no known shared ancestry. For marker subsets, similar patterns were observed but with lower prediction accuracies. Given the need for high relatedness between CV sets to obtain good prediction accuracies, we recommend to build GS models for prediction within the same breeding population only. Breeding groups could be merged to build genomic prediction models as long as the total effective population size does not exceed 50 individuals in order to obtain high prediction accuracy such as that

  12. The accuracy of Genomic Selection in Norwegian red cattle assessed by cross-validation.

    PubMed

    Luan, Tu; Woolliams, John A; Lien, Sigbjørn; Kent, Matthew; Svendsen, Morten; Meuwissen, Theo H E

    2009-11-01

    Genomic Selection (GS) is a newly developed tool for the estimation of breeding values for quantitative traits through the use of dense markers covering the whole genome. For a successful application of GS, accuracy of the prediction of genomewide breeding value (GW-EBV) is a key issue to consider. Here we investigated the accuracy and possible bias of GW-EBV prediction, using real bovine SNP genotyping (18,991 SNPs) and phenotypic data of 500 Norwegian Red bulls. The study was performed on milk yield, fat yield, protein yield, first lactation mastitis traits, and calving ease. Three methods, best linear unbiased prediction (G-BLUP), Bayesian statistics (BayesB), and a mixture model approach (MIXTURE), were used to estimate marker effects, and their accuracy and bias were estimated by using cross-validation. The accuracies of the GW-EBV prediction were found to vary widely between 0.12 and 0.62. G-BLUP gave overall the highest accuracy. We observed a strong relationship between the accuracy of the prediction and the heritability of the trait. GW-EBV prediction for production traits with high heritability achieved higher accuracy and also lower bias than health traits with low heritability. To achieve a similar accuracy for the health traits probably more records will be needed.

  13. Methodological quality of diagnostic accuracy studies on non-invasive coronary CT angiography: influence of QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) items on sensitivity and specificity.

    PubMed

    Schueler, Sabine; Walther, Stefan; Schuetz, Georg M; Schlattmann, Peter; Dewey, Marc

    2013-06-01

    To evaluate the methodological quality of diagnostic accuracy studies on coronary computed tomography (CT) angiography using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) tool. Each QUADAS item was individually defined to adapt it to the special requirements of studies on coronary CT angiography. Two independent investigators analysed 118 studies using 12 QUADAS items. Meta-regression and pooled analyses were performed to identify possible effects of methodological quality items on estimates of diagnostic accuracy. The overall methodological quality of coronary CT studies was merely moderate. They fulfilled a median of 7.5 out of 12 items. Only 9 of the 118 studies fulfilled more than 75 % of possible QUADAS items. One QUADAS item ("Uninterpretable Results") showed a significant influence (P = 0.02) on estimates of diagnostic accuracy with "no fulfilment" increasing specificity from 86 to 90 %. Furthermore, pooled analysis revealed that each QUADAS item that is not fulfilled has the potential to change estimates of diagnostic accuracy. The methodological quality of studies investigating the diagnostic accuracy of non-invasive coronary CT is only moderate and was found to affect the sensitivity and specificity. An improvement is highly desirable because good methodology is crucial for adequately assessing imaging technologies. • Good methodological quality is a basic requirement in diagnostic accuracy studies. • Most coronary CT angiography studies have only been of moderate design quality. • Weak methodological quality will affect the sensitivity and specificity. • No improvement in methodological quality was observed over time. • Authors should consider the QUADAS checklist when undertaking accuracy studies.

  14. Child Effortful Control, Teacher-student Relationships, and Achievement in Academically At-risk Children: Additive and Interactive Effects

    PubMed Central

    Liew, Jeffrey; Chen, Qi; Hughes, Jan N.

    2009-01-01

    The joint contributions of child effortful control (using inhibitory control and task accuracy as behavioral indices) and positive teacher-student relationships at first grade on reading and mathematics achievement at second grade were examined in 761 children who were predominantly from low-income and ethnic minority backgrounds and assessed to be academically at-risk at entry to first grade. Analyses accounted for clustering effects, covariates, baselines of effortful control measures, and prior levels of achievement. Even with such conservative statistical controls, interactive effects were found for task accuracy and positive teacher-student relationships on future achievement. Results suggest that task accuracy served as a protective factor so that children with high task accuracy performed well academically despite not having positive teacher-student relationships. Further, positive teacher-student relationships served as a compensatory factor so that children with low task accuracy performed just as well as those with high task accuracy if they were paired with a positive and supportive teacher. Importantly, results indicate that the influence of positive teacher-student relationships on future achievement was most pronounced for students with low effortful control on tasks that require fine motor skills, accuracy, and attention-related skills. Study results have implications for narrowing achievement disparities for academically at-risk children. PMID:20161421

  15. Child Effortful Control, Teacher-student Relationships, and Achievement in Academically At-risk Children: Additive and Interactive Effects.

    PubMed

    Liew, Jeffrey; Chen, Qi; Hughes, Jan N

    2010-01-01

    The joint contributions of child effortful control (using inhibitory control and task accuracy as behavioral indices) and positive teacher-student relationships at first grade on reading and mathematics achievement at second grade were examined in 761 children who were predominantly from low-income and ethnic minority backgrounds and assessed to be academically at-risk at entry to first grade. Analyses accounted for clustering effects, covariates, baselines of effortful control measures, and prior levels of achievement. Even with such conservative statistical controls, interactive effects were found for task accuracy and positive teacher-student relationships on future achievement. Results suggest that task accuracy served as a protective factor so that children with high task accuracy performed well academically despite not having positive teacher-student relationships. Further, positive teacher-student relationships served as a compensatory factor so that children with low task accuracy performed just as well as those with high task accuracy if they were paired with a positive and supportive teacher. Importantly, results indicate that the influence of positive teacher-student relationships on future achievement was most pronounced for students with low effortful control on tasks that require fine motor skills, accuracy, and attention-related skills. Study results have implications for narrowing achievement disparities for academically at-risk children.

  16. Measurement system with high accuracy for laser beam quality.

    PubMed

    Ke, Yi; Zeng, Ciling; Xie, Peiyuan; Jiang, Qingshan; Liang, Ke; Yang, Zhenyu; Zhao, Ming

    2015-05-20

    Presently, most of the laser beam quality measurement system collimates the optical path manually with low efficiency and low repeatability. To solve these problems, this paper proposed a new collimated method to improve the reliability and accuracy of the measurement results. The system accuracy controlled the position of the mirror to change laser beam propagation direction, which can realize the beam perpendicularly incident to the photosurface of camera. The experiment results show that the proposed system has good repeatability and the measuring deviation of M2 factor is less than 0.6%.

  17. Good Practices in Free-energy Calculations

    NASA Technical Reports Server (NTRS)

    Pohorille, Andrew; Jarzynski, Christopher; Chipot, Christopher

    2013-01-01

    As access to computational resources continues to increase, free-energy calculations have emerged as a powerful tool that can play a predictive role in drug design. Yet, in a number of instances, the reliability of these calculations can be improved significantly if a number of precepts, or good practices are followed. For the most part, the theory upon which these good practices rely has been known for many years, but often overlooked, or simply ignored. In other cases, the theoretical developments are too recent for their potential to be fully grasped and merged into popular platforms for the computation of free-energy differences. The current best practices for carrying out free-energy calculations will be reviewed demonstrating that, at little to no additional cost, free-energy estimates could be markedly improved and bounded by meaningful error estimates. In energy perturbation and nonequilibrium work methods, monitoring the probability distributions that underlie the transformation between the states of interest, performing the calculation bidirectionally, stratifying the reaction pathway and choosing the most appropriate paradigms and algorithms for transforming between states offer significant gains in both accuracy and precision. In thermodynamic integration and probability distribution (histogramming) methods, properly designed adaptive techniques yield nearly uniform sampling of the relevant degrees of freedom and, by doing so, could markedly improve efficiency and accuracy of free energy calculations without incurring any additional computational expense.

  18. ShinyGPAS: interactive genomic prediction accuracy simulator based on deterministic formulas.

    PubMed

    Morota, Gota

    2017-12-20

    Deterministic formulas for the accuracy of genomic predictions highlight the relationships among prediction accuracy and potential factors influencing prediction accuracy prior to performing computationally intensive cross-validation. Visualizing such deterministic formulas in an interactive manner may lead to a better understanding of how genetic factors control prediction accuracy. The software to simulate deterministic formulas for genomic prediction accuracy was implemented in R and encapsulated as a web-based Shiny application. Shiny genomic prediction accuracy simulator (ShinyGPAS) simulates various deterministic formulas and delivers dynamic scatter plots of prediction accuracy versus genetic factors impacting prediction accuracy, while requiring only mouse navigation in a web browser. ShinyGPAS is available at: https://chikudaisei.shinyapps.io/shinygpas/ . ShinyGPAS is a shiny-based interactive genomic prediction accuracy simulator using deterministic formulas. It can be used for interactively exploring potential factors that influence prediction accuracy in genome-enabled prediction, simulating achievable prediction accuracy prior to genotyping individuals, or supporting in-class teaching. ShinyGPAS is open source software and it is hosted online as a freely available web-based resource with an intuitive graphical user interface.

  19. The Credibility of Children's Testimony: Can Children Control the Accuracy of Their Memory Reports?

    ERIC Educational Resources Information Center

    Koriat, Asher; Goldsmith, Morris; Schneider, Wolfgang; Nakash-Dura, Michal

    2001-01-01

    Three experiments examined children's strategic regulation of memory accuracy. Found that younger (7 to 9 years) and older (10 to 12 years) children could enhance the accuracy of their testimony by screening out wrong answers under free-report conditions. Findings suggest a developmental trend in level of memory accuracy actually achieved.…

  20. Improvement of Gaofen-3 Absolute Positioning Accuracy Based on Cross-Calibration

    PubMed Central

    Deng, Mingjun; Li, Jiansong

    2017-01-01

    The Chinese Gaofen-3 (GF-3) mission was launched in August 2016, equipped with a full polarimetric synthetic aperture radar (SAR) sensor in the C-band, with a resolution of up to 1 m. The absolute positioning accuracy of GF-3 is of great importance, and in-orbit geometric calibration is a key technology for improving absolute positioning accuracy. Conventional geometric calibration is used to accurately calibrate the geometric calibration parameters of the image (internal delay and azimuth shifts) using high-precision ground control data, which are highly dependent on the control data of the calibration field, but it remains costly and labor-intensive to monitor changes in GF-3’s geometric calibration parameters. Based on the positioning consistency constraint of the conjugate points, this study presents a geometric cross-calibration method for the rapid and accurate calibration of GF-3. The proposed method can accurately calibrate geometric calibration parameters without using corner reflectors and high-precision digital elevation models, thus improving absolute positioning accuracy of the GF-3 image. GF-3 images from multiple regions were collected to verify the absolute positioning accuracy after cross-calibration. The results show that this method can achieve a calibration accuracy as high as that achieved by the conventional field calibration method. PMID:29240675

  1. Good is not good enough: the culture of low expectations and the leader's challenge.

    PubMed

    Kerfoot, Karlene M

    2009-01-01

    When people believe that what they do is "good enough," excellence will never occur. As the demand for better health care escalates every year, achieving a ranking of very good doesn't count because it leaves many disenfranchised staff, errors, and dissatisfied patients. A leader can not be successful unless the culture of low expectations is eliminated. If there isn't a sense of caring, serving, and being an exemplar of the change, the leader won't succeed in moving the culture. When there is a sense of ownership and commitment to the mission and to patients, the culture of low expectations cannot exist.

  2. Secure Fingerprint Identification of High Accuracy

    DTIC Science & Technology

    2014-01-01

    secure ) solution of complexity O(n3) based on Gaussian elimination. When it is applied to biometrics X and Y with mX and mY minutiae, respectively...collections of biometric data in use today include, for example, fingerprint, face, and iris images collected by the US Department of Homeland Security ...work we focus on fingerprint data due to popularity and good accuracy of this type of biometry. We formulate the problem of private, or secure , finger

  3. [Good agricultural practice (GAP) of Chinese materia medica (CMM) for ten years: achievements, problems and proposals].

    PubMed

    Guo, Lan-Ping; Zhang, Yan; Zhu, Shou-Dong; Wang, Gui-Hua; Wang, Xiu; Zhang, Xiao-Bo; Chen, Mei-Lan; He, Ya-Li; Han, Bang-Xing; Chen, Nai-Fu; Huang, Lu-Qi

    2014-04-01

    This paper aims to summarize the achievements during the implementation process of good agricultural practice (GAP) in Chinese Materia Medica (CMM), and on basis of analyzing the existing problems of GAP, to propose further implementation of GAP in TCM growing. Since the launch of GAP in CMM growing ten years ago, it has acquired great achievements, including: (1) The promulgation of a series of measures for the administration of the GAP approval in the CMM growing; (2) The expanded planting area of CMM; (3) The increased awareness of standardized CMM growing among farmers and enterprises; (4) The establishment of GAP implementation bases for CMM growing; (5) The improvement of theory and methodology for CMM growing; (6) The development of a large group of experts and scholars in GAP approval for CMM production. The problems existing in the production include: (1) A deep understanding of GAP and its certification is still needed; (2) The distribution of the certification base is not reasonable; (3) The geo-economics effect and the backward farming practices are thought to be the bottlenecks in the standardization of CMM growing and the scale production of CMM; (4) Low comparative effectiveness limits the development of the GAP; (5) The base of breeding improved variety is blank; (6) The immature of the cultivation technique lead to the risk of production process; (7) The degradation of soil microbial and the continuous cropping obstacle restrict the sustainable development of the GAP base. To further promote the health and orderly GAP in the CMM growing, the authors propose: (1) To change the mode of production; (2) To establish a sound standard system so as to ensure quality products for fair prices; (3) To fully consider the geo-economic culture and vigorously promote the definite cultivating of traditional Chinese medicinal materials; (4) To strengthen the transformation and generalization of basic researches and achievements, in order to provide technical

  4. Accuracy of forecasts in strategic intelligence

    PubMed Central

    Mandel, David R.; Barnes, Alan

    2014-01-01

    The accuracy of 1,514 strategic intelligence forecasts abstracted from intelligence reports was assessed. The results show that both discrimination and calibration of forecasts was very good. Discrimination was better for senior (versus junior) analysts and for easier (versus harder) forecasts. Miscalibration was mainly due to underconfidence such that analysts assigned more uncertainty than needed given their high level of discrimination. Underconfidence was more pronounced for harder (versus easier) forecasts and for forecasts deemed more (versus less) important for policy decision making. Despite the observed underconfidence, there was a paucity of forecasts in the least informative 0.4–0.6 probability range. Recalibrating the forecasts substantially reduced underconfidence. The findings offer cause for tempered optimism about the accuracy of strategic intelligence forecasts and indicate that intelligence producers aim to promote informativeness while avoiding overstatement. PMID:25024176

  5. Educating for Good Work: From Research to Practice

    ERIC Educational Resources Information Center

    Mucinskas, Daniel; Gardner, Howard

    2013-01-01

    Launched in 1995, the GoodWork Project is a long-term, multi-site effort to understand the nature of good work across the professional landscape and to promote its achievement by relevant groups of students and professionals. In this essay, the authors review the goals and methods of the initial research project and its most salient findings. They…

  6. Time needed to achieve completeness and accuracy in bedside lung ultrasound reporting in intensive care unit.

    PubMed

    Tutino, Lorenzo; Cianchi, Giovanni; Barbani, Francesco; Batacchi, Stefano; Cammelli, Rita; Peris, Adriano

    2010-08-12

    The use of lung ultrasound (LUS) in ICU is increasing but ultrasonographic patterns of lung are often difficult to quantify by different operators. The aim of this study was to evaluate the accuracy and quality of LUS reporting after the introduction of a standardized electronic recording sheet. Intensivists were trained for LUS following a teaching programme. From April 2008, an electronic sheet was designed and introduced in ICU database in order to uniform LUS examination reporting. A mark from 0 to 24 has been given for each exam by two senior intensivists not involved in the survey. The mark assigned was based on completeness of a precise reporting scheme, concerning the main finding of LUS. A cut off of 15 was considered sufficiency. The study comprehended 12 months of observations and a total of 637 LUS. Initially, although some improvement in the reports completeness, still the accuracy and precision of examination reporting was below 15. The time required to reach a sufficient quality was 7 months. A linear trend in physicians progress was observed. The uniformity in teaching programme and examinations reporting system permits to improve the level of completeness and accuracy of LUS reporting, helping physicians in following lung pathology evolution.

  7. Electroencephalography Predicts Poor and Good Outcomes After Cardiac Arrest: A Two-Center Study.

    PubMed

    Rossetti, Andrea O; Tovar Quiroga, Diego F; Juan, Elsa; Novy, Jan; White, Roger D; Ben-Hamouda, Nawfel; Britton, Jeffrey W; Oddo, Mauro; Rabinstein, Alejandro A

    2017-07-01

    The prognostic role of electroencephalography during and after targeted temperature management in postcardiac arrest patients, relatively to other predictors, is incompletely known. We assessed performances of electroencephalography during and after targeted temperature management toward good and poor outcomes, along with other recognized predictors. Cohort study (April 2009 to March 2016). Two academic hospitals (Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland; Mayo Clinic, Rochester, MN). Consecutive comatose adults admitted after cardiac arrest, identified through prospective registries. All patients were managed with targeted temperature management, receiving prespecified standardized clinical, neurophysiologic (particularly, electroencephalography during and after targeted temperature management), and biochemical evaluations. We assessed electroencephalography variables (reactivity, continuity, epileptiform features, and prespecified "benign" or "highly malignant" patterns based on the American Clinical Neurophysiology Society nomenclature) and other clinical, neurophysiologic (somatosensory-evoked potential), and biochemical prognosticators. Good outcome (Cerebral Performance Categories 1 and 2) and mortality predictions at 3 months were calculated. Among 357 patients, early electroencephalography reactivity and continuity and flexor or better motor reaction had greater than 70% positive predictive value for good outcome; reactivity (80.4%; 95% CI, 75.9-84.4%) and motor response (80.1%; 95% CI, 75.6-84.1%) had highest accuracy. Early benign electroencephalography heralded good outcome in 86.2% (95% CI, 79.8-91.1%). False positive rates for mortality were less than 5% for epileptiform or nonreactive early electroencephalography, nonreactive late electroencephalography, absent somatosensory-evoked potential, absent pupillary or corneal reflexes, presence of myoclonus, and neuron-specific enolase greater than 75 µg/L; accuracy was highest for

  8. Small Body Landing Accuracy Using In-Situ Navigation

    NASA Technical Reports Server (NTRS)

    Bhaskaran, Shyam; Nandi, Sumita; Broschart, Stephen; Wallace, Mark; Olson, Corwin; Cangahuala, L. Alberto

    2011-01-01

    Spacecraft landings on small bodies (asteroids and comets) can require target accuracies too stringent to be met using ground-based navigation alone, especially if specific landing site requirements must be met for safety or to meet science goals. In-situ optical observations coupled with onboard navigation processing can meet the tighter accuracy requirements to enable such missions. Recent developments in deep space navigation capability include a self-contained autonomous navigation system (used in flight on three missions) and a landmark tracking system (used experimentally on the Japanese Hayabusa mission). The merging of these two technologies forms a methodology to perform autonomous onboard navigation around small bodies. This paper presents an overview of these systems, as well as the results from Monte Carlo studies to quantify the achievable landing accuracies by using these methods. Sensitivity of the results to variations in spacecraft maneuver execution error, attitude control accuracy and unmodeled forces are examined. Cases for two bodies, a small asteroid and on a mid-size comet, are presented.

  9. Design and Application of Automatic Falling Device for Different Brands of Goods

    NASA Astrophysics Data System (ADS)

    Yang, Xudong; Ge, Qingkuan; Zuo, Ping; Peng, Tao; Dong, Weifu

    2017-12-01

    The Goods-Falling device is an important device in the intelligent sorting goods sorting system, which is responsible for the temporary storage and counting of the goods, and the function of putting the goods on the conveyor belt according to certain precision requirements. According to the present situation analysis and actual demand of the domestic goods sorting equipment, a vertical type Goods - Falling Device is designed and the simulation model of the device is established. The dynamic characteristics such as the angular error of the opening and closing mechanism are carried out by ADAMS software. The simulation results show that the maximum angular error is 0.016rad. Through the test of the device, the goods falling speed is 7031/hour, the good of the falling position error within 2mm, meet the crawl accuracy requirements of the palletizing robot.

  10. Good breastfeeding policies -- good breastfeeding rates.

    PubMed

    1998-01-01

    In Norway, where breast-feeding policies protecting breast-feeding women's needs have been in place since the 1970s, approximately 97% of women breast feed when leaving the hospital, 80% are breast feeding at 3 months, and 20% beyond 12 months. Government family policies play an important role in enabling women to achieve good breast-feeding rates. In Norway: maternity leave is 42 weeks with full pay or 52 weeks with 80% of salary; flexible part-time is available for women from 2 months after giving birth with income supplemented from maternity benefits; after returning to work, women are entitled to 1- to 1.5-hour breaks to return home to breast feed, or to have the child brought to work. "Breast feeding is so normal," writes Hege Jacobson Lepri, "it's more embarrassing to bring out the feeding bottle in public." full text

  11. Accuracy requirements and uncertainties in radiotherapy: a report of the International Atomic Energy Agency.

    PubMed

    van der Merwe, Debbie; Van Dyk, Jacob; Healy, Brendan; Zubizarreta, Eduardo; Izewska, Joanna; Mijnheer, Ben; Meghzifene, Ahmed

    2017-01-01

    Radiotherapy technology continues to advance and the expectation of improved outcomes requires greater accuracy in various radiotherapy steps. Different factors affect the overall accuracy of dose delivery. Institutional comprehensive quality assurance (QA) programs should ensure that uncertainties are maintained at acceptable levels. The International Atomic Energy Agency has recently developed a report summarizing the accuracy achievable and the suggested action levels, for each step in the radiotherapy process. Overview of the report: The report seeks to promote awareness and encourage quantification of uncertainties in order to promote safer and more effective patient treatments. The radiotherapy process and the radiobiological and clinical frameworks that define the need for accuracy are depicted. Factors that influence uncertainty are described for a range of techniques, technologies and systems. Methodologies for determining and combining uncertainties are presented, and strategies for reducing uncertainties through QA programs are suggested. The role of quality audits in providing international benchmarking of achievable accuracy and realistic action levels is also discussed. The report concludes with nine general recommendations: (1) Radiotherapy should be applied as accurately as reasonably achievable, technical and biological factors being taken into account. (2) For consistency in prescribing, reporting and recording, recommendations of the International Commission on Radiation Units and Measurements should be implemented. (3) Each institution should determine uncertainties for their treatment procedures. Sample data are tabulated for typical clinical scenarios with estimates of the levels of accuracy that are practically achievable and suggested action levels. (4) Independent dosimetry audits should be performed regularly. (5) Comprehensive quality assurance programs should be in place. (6) Professional staff should be appropriately

  12. High Accuracy Monocular SFM and Scale Correction for Autonomous Driving.

    PubMed

    Song, Shiyu; Chandraker, Manmohan; Guest, Clark C

    2016-04-01

    We present a real-time monocular visual odometry system that achieves high accuracy in real-world autonomous driving applications. First, we demonstrate robust monocular SFM that exploits multithreading to handle driving scenes with large motions and rapidly changing imagery. To correct for scale drift, we use known height of the camera from the ground plane. Our second contribution is a novel data-driven mechanism for cue combination that allows highly accurate ground plane estimation by adapting observation covariances of multiple cues, such as sparse feature matching and dense inter-frame stereo, based on their relative confidences inferred from visual data on a per-frame basis. Finally, we demonstrate extensive benchmark performance and comparisons on the challenging KITTI dataset, achieving accuracy comparable to stereo and exceeding prior monocular systems. Our SFM system is optimized to output pose within 50 ms in the worst case, while average case operation is over 30 fps. Our framework also significantly boosts the accuracy of applications like object localization that rely on the ground plane.

  13. Accuracy of Estimating Solar Radiation Pressure for GEO Debris with Tumbling Effect

    NASA Astrophysics Data System (ADS)

    Chao, Chia-Chun George

    2009-03-01

    The accuracy of estimating solar radiation pressure for GEO debris is examined and demonstrated, via numerical simulations, by fitting a batch (months) of simulated position vectors. These simulated position vectors are generated from a "truth orbit" with added white noise using high-precision numerical integration tools. After the long-arc fit of the simulated observations (position vectors), one can accurately and reliably determine how close the estimated value of solar radiation pressure is to the truth. Results of this study show that the inherent accuracy in estimating the solar radiation pressure coefficient can be as good as 1% if a long-arc fit span up to 180 days is used and the satellite is not tumbling. The corresponding position prediction accuracy can be as good as, in maximum error, 1 km along in-track, 0.3 km along radial and 0.1 km along cross-track up to 30 days. Similar accuracies can be expected when the object is tumbling as long as the rate of attitude change is different from the orbit rate. Results of this study reveal an important phenomenon that the solar radiation pressure significantly affects the orbit motion when the spin rate is equal to the orbit rate.

  14. Achieving sub-pixel geolocation accuracy in support of MODIS land science

    USGS Publications Warehouse

    Wolfe, R.E.; Nishihama, M.; Fleig, A.J.; Kuyper, J.A.; Roy, David P.; Storey, James C.; Patt, F.S.

    2002-01-01

    The Moderate Resolution Imaging Spectroradiometer (MODIS) was launched in December 1999 on the polar orbiting Terra spacecraft and since February 2000 has been acquiring daily global data in 36 spectral bands—29 with 1 km, five with 500 m, and two with 250 m nadir pixel dimensions. The Terra satellite has on-board exterior orientation (position and attitude) measurement systems designed to enable geolocation of MODIS data to approximately 150 m (1σ) at nadir. A global network of ground control points is being used to determine biases and trends in the sensor orientation. Biases have been removed by updating models of the spacecraft and instrument orientation in the MODIS geolocation software several times since launch and have improved the MODIS geolocation to approximately 50 m (1σ) at nadir. This paper overviews the geolocation approach, summarizes the first year of geolocation analysis, and overviews future work. The approach allows an operational characterization of the MODIS geolocation errors and enables individual MODIS observations to be geolocated to the sub-pixel accuracies required for terrestrial global change applications.

  15. Acquisition and Retention of Sterile Compounding Accuracy Skills

    PubMed Central

    Brown, Michael C.; Valdovinos, Katie; Zavala, Pedro J.

    2017-01-01

    Objective. To determine the accuracy of dose of pharmacy students’ parenteral sterile preparation skills and to measure pharmacy students’ skill retention 1.5 years later. Methods. An exercise was designed to assess each student’s accuracy in compounding a sterile preparation with the correct potency during a second and then third year course. Results. Initially, the mean (standard deviation) of 141 students’ compounded preparation dose was not significantly different than the desired dose. Additionally, 91.5% of products were within 10% of the desired dose. In the follow-up activity the next academic year, the mean dose was not significantly different than the original compounded dose. Similarly 92.9% were within 10% of the desired dose. Conclusion. Students’ overall accuracy of sterile compounding was good initially and well-retained more than a year later, with more than 90% of students being within 10% of the desired dose in both courses. PMID:28970616

  16. Validity of a commercial wearable sleep tracker in adult insomnia disorder patients and good sleepers.

    PubMed

    Kang, Seung-Gul; Kang, Jae Myeong; Ko, Kwang-Pil; Park, Seon-Cheol; Mariani, Sara; Weng, Jia

    2017-06-01

    To compare the accuracy of the commercial Fitbit Flex device (FF) with polysomnography (PSG; the gold-standard method) in insomnia disorder patients and good sleepers. Participants wore an FF and actigraph while undergoing overnight PSG. Primary outcomes were intraclass correlation coefficients (ICCs) of the total sleep time (TST) and sleep efficiency (SE), and the frequency of clinically acceptable agreement between the FF in normal mode (FFN) and PSG. The sensitivity, specificity, and accuracy of detecting sleep epochs were compared among FFN, actigraphy, and PSG. The ICCs of the TST between FFN and PSG in the insomnia (ICC=0.886) and good-sleepers (ICC=0.974) groups were excellent, but the ICC of SE was only fair in both groups. The TST and SE were overestimated for FFN by 6.5min and 1.75%, respectively, in good sleepers, and by 32.9min and 7.9% in the insomnia group with respect to PSG. The frequency of acceptable agreement of FFN and PSG was significantly lower (p=0.006) for the insomnia group (39.4%) than for the good-sleepers group (82.4%). The sensitivity and accuracy of FFN in an epoch-by-epoch comparison with PSG was good and comparable to those of actigraphy, but the specificity was poor in both groups. The ICC of TST in the FFN-PSG comparison was excellent in both groups, and the frequency of agreement was high in good sleepers but significantly lower in insomnia patients. These limitations need to be considered when applying commercial sleep trackers for clinical and research purposes in insomnia. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Decreased Sperm Motility Retarded ICSI Fertilization Rate in Severe Oligozoospermia but Good-Quality Embryo Transfer Had Achieved the Prospective Clinical Outcomes.

    PubMed

    Zheng, Jufeng; Lu, Yongning; Qu, Xianqin; Wang, Peng; Zhao, Luiwen; Gao, Minzhi; Shi, Huijuan; Jin, Xingliang

    .26% clinical pregnancy, 25.74% implantation and 36.32% live birth, which gave live birth to 252 girls and 252 boys. The reduction of motile spermatozoa in severe oligozoospermia decreased the rates of fertilization and good-quality embryo. Obtaining and transfer of good-quality embryos was the good prognostic to achieve prospective clinical outcomes regardless of the severity of oligozoospermia.

  18. Factors Governing Surface Form Accuracy In Diamond Machined Components

    NASA Astrophysics Data System (ADS)

    Myler, J. K.; Page, D. A.

    1988-10-01

    Manufacturing methods for diamond machined optical surfaces, for application at infrared wavelengths, require that a new set of criteria must be recognised for the specification of surface form. Appropriate surface form parameters are discussed with particular reference to an XY cartesian geometry CNC machine. Methods for reducing surface form errors in diamond machining are discussed for certain areas such as tool wear, tool centring, and the fixturing of the workpiece. Examples of achievable surface form accuracy are presented. Traditionally, optical surfaces have been produced by use of random polishing techniques using polishing compounds and lapping tools. For lens manufacture, the simplest surface which could be created corresponded to a sphere. The sphere is a natural outcome of a random grinding and polishing process. The measurement of the surface form accuracy would most commonly be performed using a contact test gauge plate, polished to a sphere of known radius of curvature. QA would simply be achieved using a diffuse monochromatic source and looking for residual deviations between the polished surface and the test plate. The specifications governing the manufacture of surfaces using these techniques would call for the accuracy to which the generated surface should match the test plate as defined by a spherical deviations from the required curvature and a non spherical astigmatic error. Consequently, optical design software has tolerancing routines which specifically allow the designer to assess the influence of spherical error and astigmatic error on the optical performance. The creation of general aspheric surfaces is not so straightforward using conventional polishing techniques since the surface profile is non spherical and a good approximation to a power series. For infra red applications (X = 8-12p,m) numerically controlled single point diamond turning is an alternative manufacturing technology capable of creating aspheric profiles as well as

  19. High-accuracy user identification using EEG biometrics.

    PubMed

    Koike-Akino, Toshiaki; Mahajan, Ruhi; Marks, Tim K; Ye Wang; Watanabe, Shinji; Tuzel, Oncel; Orlik, Philip

    2016-08-01

    We analyze brain waves acquired through a consumer-grade EEG device to investigate its capabilities for user identification and authentication. First, we show the statistical significance of the P300 component in event-related potential (ERP) data from 14-channel EEGs across 25 subjects. We then apply a variety of machine learning techniques, comparing the user identification performance of various different combinations of a dimensionality reduction technique followed by a classification algorithm. Experimental results show that an identification accuracy of 72% can be achieved using only a single 800 ms ERP epoch. In addition, we demonstrate that the user identification accuracy can be significantly improved to more than 96.7% by joint classification of multiple epochs.

  20. Towards more efficient burn care: Identifying factors associated with good quality of life post-burn.

    PubMed

    Finlay, V; Phillips, M; Allison, G T; Wood, F M; Ching, D; Wicaksono, D; Plowman, S; Hendrie, D; Edgar, D W

    2015-11-01

    As minor burn patients constitute the vast majority of a developed nation case-mix, streamlining care for this group can promote efficiency from a service-wide perspective. This study tested the hypothesis that a predictive nomogram model that estimates likelihood of good long-term quality of life (QoL) post-burn is a valid way to optimise patient selection and risk management when applying a streamlined model of care. A sample of 224 burn patients managed by the Burn Service of Western Australia who provided both short and long-term outcomes was used to estimate the probability of achieving a good QoL defined as 150 out of a possible 160 points on the Burn Specific Health Scale-Brief (BSHS-B) at least six months from injury. A multivariate logistic regression analysis produced a predictive model provisioned as a nomogram for clinical application. A second, independent cohort of consecutive patients (n=106) was used to validate the predictive merit of the nomogram. Male gender (p=0.02), conservative management (p=0.03), upper limb burn (p=0.04) and high BSHS-B score within one month of burn (p<0.001) were significant predictors of good outcome at six months and beyond. A Receiver Operating Curve (ROC) analysis demonstrated excellent (90%) accuracy overall. At 80% probability of good outcome, the false positive risk was 14%. The nomogram was validated by running a second ROC analysis of the model in an independent cohort. The analysis confirmed high (86%) overall accuracy of the model, the risk of false positive was reduced to 10% at a lower (70%) probability. This affirms the stability of the nomogram model in different patient groups over time. An investigation of the effect of missing data on sample selection determined that a greater proportion of younger patients with smaller TBSA burns were excluded due to loss to follow up. For clinicians managing comparable burn populations, the BSWA burns nomogram is an effective tool to assist the selection of patients to

  1. Automated Registration of Multimodal Optic Disc Images: Clinical Assessment of Alignment Accuracy.

    PubMed

    Ng, Wai Siene; Legg, Phil; Avadhanam, Venkat; Aye, Kyaw; Evans, Steffan H P; North, Rachel V; Marshall, Andrew D; Rosin, Paul; Morgan, James E

    2016-04-01

    To determine the accuracy of automated alignment algorithms for the registration of optic disc images obtained by 2 different modalities: fundus photography and scanning laser tomography. Images obtained with the Heidelberg Retina Tomograph II and paired photographic optic disc images of 135 eyes were analyzed. Three state-of-the-art automated registration techniques Regional Mutual Information, rigid Feature Neighbourhood Mutual Information (FNMI), and nonrigid FNMI (NRFNMI) were used to align these image pairs. Alignment of each composite picture was assessed on a 5-point grading scale: "Fail" (no alignment of vessels with no vessel contact), "Weak" (vessels have slight contact), "Good" (vessels with <50% contact), "Very Good" (vessels with >50% contact), and "Excellent" (complete alignment). Custom software generated an image mosaic in which the modalities were interleaved as a series of alternate 5×5-pixel blocks. These were graded independently by 3 clinically experienced observers. A total of 810 image pairs were assessed. All 3 registration techniques achieved a score of "Good" or better in >95% of the image sets. NRFNMI had the highest percentage of "Excellent" (mean: 99.6%; range, 95.2% to 99.6%), followed by Regional Mutual Information (mean: 81.6%; range, 86.3% to 78.5%) and FNMI (mean: 73.1%; range, 85.2% to 54.4%). Automated registration of optic disc images by different modalities is a feasible option for clinical application. All 3 methods provided useful levels of alignment, but the NRFNMI technique consistently outperformed the others and is recommended as a practical approach to the automated registration of multimodal disc images.

  2. You are so beautiful... to me: seeing beyond biases and achieving accuracy in romantic relationships.

    PubMed

    Solomon, Brittany C; Vazire, Simine

    2014-09-01

    Do romantic partners see each other realistically, or do they have overly positive perceptions of each other? Research has shown that realism and positivity co-exist in romantic partners' perceptions (Boyes & Fletcher, 2007). The current study takes a novel approach to explaining this seemingly paradoxical effect when it comes to physical attractiveness--a highly evaluative trait that is especially relevant to romantic relationships. Specifically, we argue that people are aware that others do not see their partners as positively as they do. Using both mean differences and correlational approaches, we test the hypothesis that despite their own biased and idiosyncratic perceptions, people have 2 types of partner-knowledge: insight into how their partners see themselves (i.e., identity accuracy) and insight into how others see their partners (i.e., reputation accuracy). Our results suggest that romantic partners have some awareness of each other's identity and reputation for physical attractiveness, supporting theories that couple members' perceptions are driven by motives to fulfill both esteem- and epistemic-related needs (i.e., to see their partners positively and realistically). 2014 APA, all rights reserved

  3. Assessment of the Thematic Accuracy of Land Cover Maps

    NASA Astrophysics Data System (ADS)

    Höhle, J.

    2015-08-01

    Several land cover maps are generated from aerial imagery and assessed by different approaches. The test site is an urban area in Europe for which six classes (`building', `hedge and bush', `grass', `road and parking lot', `tree', `wall and car port') had to be derived. Two classification methods were applied (`Decision Tree' and `Support Vector Machine') using only two attributes (height above ground and normalized difference vegetation index) which both are derived from the images. The assessment of the thematic accuracy applied a stratified design and was based on accuracy measures such as user's and producer's accuracy, and kappa coefficient. In addition, confidence intervals were computed for several accuracy measures. The achieved accuracies and confidence intervals are thoroughly analysed and recommendations are derived from the gained experiences. Reliable reference values are obtained using stereovision, false-colour image pairs, and positioning to the checkpoints with 3D coordinates. The influence of the training areas on the results is studied. Cross validation has been tested with a few reference points in order to derive approximate accuracy measures. The two classification methods perform equally for five classes. Trees are classified with a much better accuracy and a smaller confidence interval by means of the decision tree method. Buildings are classified by both methods with an accuracy of 99% (95% CI: 95%-100%) using independent 3D checkpoints. The average width of the confidence interval of six classes was 14% of the user's accuracy.

  4. Applications and accuracy of the parallel diagonal dominant algorithm

    NASA Technical Reports Server (NTRS)

    Sun, Xian-He

    1993-01-01

    The Parallel Diagonal Dominant (PDD) algorithm is a highly efficient, ideally scalable tridiagonal solver. In this paper, a detailed study of the PDD algorithm is given. First the PDD algorithm is introduced. Then the algorithm is extended to solve periodic tridiagonal systems. A variant, the reduced PDD algorithm, is also proposed. Accuracy analysis is provided for a class of tridiagonal systems, the symmetric, and anti-symmetric Toeplitz tridiagonal systems. Implementation results show that the analysis gives a good bound on the relative error, and the algorithm is a good candidate for the emerging massively parallel machines.

  5. Black Working Class Adolescents' Attitudes Toward Academic Achievement.

    ERIC Educational Resources Information Center

    Mickelson, Roslyn Arlin

    This paper examines the discrepancy between black working class students' positive attitudes toward academic achievement and their failure to achieve good grades. The research presented was drawn from a study which altered a high school's reward structure, and then tested its effects on student attitudes toward academic achievement. The results of…

  6. The global public good concept: a means of promoting good veterinary governance.

    PubMed

    Eloit, M

    2012-08-01

    At the outset, the concept of a 'public good' was associated with economic policies. However, it has now evolved not only from a national to a global concept (global public good), but also from a concept applying solely to the production of goods to one encompassing societal issues (education, environment, etc.) and fundamental rights, including the right to health and food. Through their actions, Veterinary Services, as defined by the Terrestrial Animal Health Code (Terrestrial Code) of the World Organisation for Animal Health (OIE), help to improve animal health and reduce production losses. In this way they contribute directly and indirectly to food security and to safeguarding human health and economic resources. The organisation and operating procedures of Veterinary Services are therefore key to the efficient governance required to achieve these objectives. The OIE is a major player in global cooperation and governance in the fields of animal and public health through the implementation of its strategic standardisation mission and other programmes for the benefit of Veterinary Services and OIE Member Countries. Thus, the actions of Veterinary Services and the OIE deserve to be recognised as a global public good, backed by public investment to ensure that all Veterinary Services are in a position to apply the principles of good governance and to comply with the international standards for the quality of Veterinary Services set out in the OIE Terrestrial Code (Section 3 on Quality of Veterinary Services) and Aquatic Animal Health Code (Section 3 on Quality of Aquatic Animal Health Services).

  7. A Robust High-Accuracy Ultrasound Indoor Positioning System Based on a Wireless Sensor Network

    PubMed Central

    Qi, Jun; Liu, Guo-Ping

    2017-01-01

    This paper describes the development and implementation of a robust high-accuracy ultrasonic indoor positioning system (UIPS). The UIPS consists of several wireless ultrasonic beacons in the indoor environment. Each of them has a fixed and known position coordinate and can collect all the transmissions from the target node or emit ultrasonic signals. Every wireless sensor network (WSN) node has two communication modules: one is WiFi, that transmits the data to the server, and the other is the radio frequency (RF) module, which is only used for time synchronization between different nodes, with accuracy up to 1 μs. The distance between the beacon and the target node is calculated by measuring the time-of-flight (TOF) for the ultrasonic signal, and then the position of the target is computed by some distances and the coordinate of the beacons. TOF estimation is the most important technique in the UIPS. A new time domain method to extract the envelope of the ultrasonic signals is presented in order to estimate the TOF. This method, with the envelope detection filter, estimates the value with the sampled values on both sides based on the least squares method (LSM). The simulation results show that the method can achieve envelope detection with a good filtering effect by means of the LSM. The highest precision and variance can reach 0.61 mm and 0.23 mm, respectively, in pseudo-range measurements with UIPS. A maximum location error of 10.2 mm is achieved in the positioning experiments for a moving robot, when UIPS works on the line-of-sight (LOS) signal. PMID:29113126

  8. A Robust High-Accuracy Ultrasound Indoor Positioning System Based on a Wireless Sensor Network.

    PubMed

    Qi, Jun; Liu, Guo-Ping

    2017-11-06

    This paper describes the development and implementation of a robust high-accuracy ultrasonic indoor positioning system (UIPS). The UIPS consists of several wireless ultrasonic beacons in the indoor environment. Each of them has a fixed and known position coordinate and can collect all the transmissions from the target node or emit ultrasonic signals. Every wireless sensor network (WSN) node has two communication modules: one is WiFi, that transmits the data to the server, and the other is the radio frequency (RF) module, which is only used for time synchronization between different nodes, with accuracy up to 1 μ s. The distance between the beacon and the target node is calculated by measuring the time-of-flight (TOF) for the ultrasonic signal, and then the position of the target is computed by some distances and the coordinate of the beacons. TOF estimation is the most important technique in the UIPS. A new time domain method to extract the envelope of the ultrasonic signals is presented in order to estimate the TOF. This method, with the envelope detection filter, estimates the value with the sampled values on both sides based on the least squares method (LSM). The simulation results show that the method can achieve envelope detection with a good filtering effect by means of the LSM. The highest precision and variance can reach 0.61 mm and 0.23 mm, respectively, in pseudo-range measurements with UIPS. A maximum location error of 10.2 mm is achieved in the positioning experiments for a moving robot, when UIPS works on the line-of-sight (LOS) signal.

  9. Achieving Good Perioperative Outcomes After Pancreaticoduodenectomy in a Low-Volume Setting: A 25-Year Experience

    PubMed Central

    Chedid, Aljamir D.; Chedid, Marcio F.; Winkelmann, Leonardo V.; Filho, Tomaz J. M. Grezzana; Kruel, Cleber D. P.

    2015-01-01

    Perioperative mortality following pancreaticoduodenectomy has improved over time and is lower than 5% in selected high-volume centers. Based on several large literature series on pancreaticoduodenectomy from high-volume centers, some defend that high annual volumes are necessary for good outcomes after pancreaticoduodenectomy. We report here the outcomes of a low annual volume pancreaticoduodenectomy series after incorporating technical expertise from a high-volume center. We included all patients who underwent pancreaticoduodenectomy performed by a single surgeon (ADC.) as treatment for periampullary malignancies from 1981 to 2005. Outcomes of this series were compared to those of 3 high-volume literature series. Additionally, outcomes for first 10 cases in the present series were compared to those of all 37 remaining cases in this series. A total of 47 pancreaticoduodenectomies were performed over a 25-year period. Overall in-hospital mortality was 2 cases (4.3%), and morbidity occurred in 23 patients (48.9%). Both mortality and morbidity were similar to those of each of the three high-volume center comparison series. Comparison of the outcomes for the first 10 to the remaining 37 cases in this series revealed that the latter 37 cases had inferior mortality (20% versus 0%; P = 0.042), less tumor-positive margins (50 versus 13.5%; P = 0.024), less use of intraoperative blood transfusions (90% versus 32.4%; P = 0.003), and tendency to a shorter length of in-hospital stay (20 versus 15.8 days; P = 0.053). Accumulation of surgical experience and incorporation of expertise from high-volume centers may enable achieving satisfactory outcomes after pancreaticoduodenectomy in low-volume settings whenever referral to a high-volume center is limited. PMID:25875555

  10. Accuracy increase of self-compensator

    NASA Astrophysics Data System (ADS)

    Zhambalova, S. Ts; Vinogradova, A. A.

    2018-03-01

    In this paper, the authors consider a self-compensation system and a method for increasing its accuracy, without compromising the condition of the information theory of measuring devices. The result can be achieved using the pulse control of the tracking system in the dead zone (the zone of the proportional section of the amplifier's characteristic). Pulse control allows one to increase the control power, but the input signal of the amplifier is infinitesimal. To do this, the authors use the conversion scheme for the input quantity. It is also possible to reduce the dead band, but the system becomes unstable. The amount of information received from the instrument, correcting circuits complicates the system, and, reducing the feedback coefficient dramatically, reduces the speed. Thanks to this, without compromising the measurement condition, the authors increase the accuracy of the self-compensation system. The implementation technique allows increasing the power of the input signal by many orders of magnitude.

  11. Accuracy assessment of high resolution satellite imagery orientation by leave-one-out method

    NASA Astrophysics Data System (ADS)

    Brovelli, Maria Antonia; Crespi, Mattia; Fratarcangeli, Francesca; Giannone, Francesca; Realini, Eugenio

    Interest in high-resolution satellite imagery (HRSI) is spreading in several application fields, at both scientific and commercial levels. Fundamental and critical goals for the geometric use of this kind of imagery are their orientation and orthorectification, processes able to georeference the imagery and correct the geometric deformations they undergo during acquisition. In order to exploit the actual potentialities of orthorectified imagery in Geomatics applications, the definition of a methodology to assess the spatial accuracy achievable from oriented imagery is a crucial topic. In this paper we want to propose a new method for accuracy assessment based on the Leave-One-Out Cross-Validation (LOOCV), a model validation method already applied in different fields such as machine learning, bioinformatics and generally in any other field requiring an evaluation of the performance of a learning algorithm (e.g. in geostatistics), but never applied to HRSI orientation accuracy assessment. The proposed method exhibits interesting features which are able to overcome the most remarkable drawbacks involved by the commonly used method (Hold-Out Validation — HOV), based on the partitioning of the known ground points in two sets: the first is used in the orientation-orthorectification model (GCPs — Ground Control Points) and the second is used to validate the model itself (CPs — Check Points). In fact the HOV is generally not reliable and it is not applicable when a low number of ground points is available. To test the proposed method we implemented a new routine that performs the LOOCV in the software SISAR, developed by the Geodesy and Geomatics Team at the Sapienza University of Rome to perform the rigorous orientation of HRSI; this routine was tested on some EROS-A and QuickBird images. Moreover, these images were also oriented using the world recognized commercial software OrthoEngine v. 10 (included in the Geomatica suite by PCI), manually performing the LOOCV

  12. Accuracy of Rhenium-188 SPECT/CT activity quantification for applications in radionuclide therapy using clinical reconstruction methods.

    PubMed

    Esquinas, Pedro L; Uribe, Carlos F; Gonzalez, M; Rodríguez-Rodríguez, Cristina; Häfeli, Urs O; Celler, Anna

    2017-07-20

    The main applications of 188 Re in radionuclide therapies include trans-arterial liver radioembolization and palliation of painful bone-metastases. In order to optimize 188 Re therapies, the accurate determination of radiation dose delivered to tumors and organs at risk is required. Single photon emission computed tomography (SPECT) can be used to perform such dosimetry calculations. However, the accuracy of dosimetry estimates strongly depends on the accuracy of activity quantification in 188 Re images. In this study, we performed a series of phantom experiments aiming to investigate the accuracy of activity quantification for 188 Re SPECT using high-energy and medium-energy collimators. Objects of different shapes and sizes were scanned in Air, non-radioactive water (Cold-water) and water with activity (Hot-water). The ordered subset expectation maximization algorithm with clinically available corrections (CT-based attenuation, triple-energy window (TEW) scatter and resolution recovery was used). For high activities, the dead-time corrections were applied. The accuracy of activity quantification was evaluated using the ratio of the reconstructed activity in each object to this object's true activity. Each object's activity was determined with three segmentation methods: a 1% fixed threshold (for cold background), a 40% fixed threshold and a CT-based segmentation. Additionally, the activity recovered in the entire phantom, as well as the average activity concentration of the phantom background were compared to their true values. Finally, Monte-Carlo simulations of a commercial [Formula: see text]-camera were performed to investigate the accuracy of the TEW method. Good quantification accuracy (errors  <10%) was achieved for the entire phantom, the hot-background activity concentration and for objects in cold background segmented with a 1% threshold. However, the accuracy of activity quantification for objects segmented with 40% threshold or CT-based methods

  13. Accuracy Assessment of Underwater Photogrammetric Three Dimensional Modelling for Coral Reefs

    NASA Astrophysics Data System (ADS)

    Guo, T.; Capra, A.; Troyer, M.; Gruen, A.; Brooks, A. J.; Hench, J. L.; Schmitt, R. J.; Holbrook, S. J.; Dubbini, M.

    2016-06-01

    Recent advances in automation of photogrammetric 3D modelling software packages have stimulated interest in reconstructing highly accurate 3D object geometry in unconventional environments such as underwater utilizing simple and low-cost camera systems. The accuracy of underwater 3D modelling is affected by more parameters than in single media cases. This study is part of a larger project on 3D measurements of temporal change of coral cover in tropical waters. It compares the accuracies of 3D point clouds generated by using images acquired from a system camera mounted in an underwater housing and the popular GoPro cameras respectively. A precisely measured calibration frame was placed in the target scene in order to provide accurate control information and also quantify the errors of the modelling procedure. In addition, several objects (cinder blocks) with various shapes were arranged in the air and underwater and 3D point clouds were generated by automated image matching. These were further used to examine the relative accuracy of the point cloud generation by comparing the point clouds of the individual objects with the objects measured by the system camera in air (the best possible values). Given a working distance of about 1.5 m, the GoPro camera can achieve a relative accuracy of 1.3 mm in air and 2.0 mm in water. The system camera achieved an accuracy of 1.8 mm in water, which meets our requirements for coral measurement in this system.

  14. Diagnostic accuracy for major depression in multiple sclerosis using self-report questionnaires.

    PubMed

    Fischer, Anja; Fischer, Marcus; Nicholls, Robert A; Lau, Stephanie; Poettgen, Jana; Patas, Kostas; Heesen, Christoph; Gold, Stefan M

    2015-09-01

    Multiple sclerosis and major depressive disorder frequently co-occur but depression often remains undiagnosed in this population. Self-rated depression questionnaires are a good option where clinician-based standardized diagnostics are not feasible. However, there is a paucity of data on diagnostic accuracy of self-report measures for depression in multiple sclerosis (MS). Moreover, head-to-head comparisons of common questionnaires are largely lacking. This could be particularly relevant for high-risk patients with depressive symptoms. Here, we compare the diagnostic accuracy of the Beck Depression Inventory (BDI) and 30-item version of the Inventory of Depressive Symptomatology Self-Rated (IDS-SR30) for major depressive disorder (MSS) against diagnosis by a structured clinical interview. Patients reporting depressive symptoms completed the BDI, the IDS-SR30 and underwent diagnostic assessment (Mini International Neuropsychiatric Interview, M.I.N.I.). Receiver-Operating Characteristic analyses were performed, providing error estimates and false-positive/negative rates of suggested thresholds. Data from n = 31 MS patients were available. BDI and IDS-SR30 total score were significantly correlated (r = 0.82). The IDS-SR30total score, cognitive subscore, and BDI showed excellent to good accuracy (area under the curve (AUC) 0.86, 0.91, and 0.85, respectively). Both the IDS-SR30 and the BDI are useful to quantify depressive symptoms showing good sensitivity and specificity. The IDS-SR30 cognitive subscale may be useful as a screening tool and to quantify affective/cognitive depressive symptomatology.

  15. Accuracy Assessment of Professional Grade Unmanned Systems for High Precision Airborne Mapping

    NASA Astrophysics Data System (ADS)

    Mostafa, M. M. R.

    2017-08-01

    Recently, sophisticated multi-sensor systems have been implemented on-board modern Unmanned Aerial Systems. This allows for producing a variety of mapping products for different mapping applications. The resulting accuracies match the traditional well engineered manned systems. This paper presents the results of a geometric accuracy assessment project for unmanned systems equipped with multi-sensor systems for direct georeferencing purposes. There are a number of parameters that either individually or collectively affect the quality and accuracy of a final airborne mapping product. This paper focuses on identifying and explaining these parameters and their mutual interaction and correlation. Accuracy Assessment of the final ground object positioning accuracy is presented through real-world 8 flight missions that were flown in Quebec, Canada. The achievable precision of map production is addressed in some detail.

  16. Accuracy, calibration and clinical performance of the EuroSCORE: can we reduce the number of variables?

    PubMed

    Ranucci, Marco; Castelvecchio, Serenella; Menicanti, Lorenzo; Frigiola, Alessandro; Pelissero, Gabriele

    2010-03-01

    The European system for cardiac operative risk evaluation (EuroSCORE) is currently used in many institutions and is considered a reference tool in many countries. We hypothesised that too many variables were included in the EuroSCORE using limited patient series. We tested different models using a limited number of variables. A total of 11150 adult patients undergoing cardiac operations at our institution (2001-2007) were retrospectively analysed. The 17 risk factors composing the EuroSCORE were separately analysed and ranked for accuracy of prediction of hospital mortality. Seventeen models were created by progressively including one factor at a time. The models were compared for accuracy with a receiver operating characteristics (ROC) analysis and area under the curve (AUC) evaluation. Calibration was tested with Hosmer-Lemeshow statistics. Clinical performance was assessed by comparing the predicted with the observed mortality rates. The best accuracy (AUC 0.76) was obtained using a model including only age, left ventricular ejection fraction, serum creatinine, emergency operation and non-isolated coronary operation. The EuroSCORE AUC (0.75) was not significantly different. Calibration and clinical performance were better in the five-factor model than in the EuroSCORE. Only in high-risk patients were 12 factors needed to achieve a good performance. Including many factors in multivariable logistic models increases the risk for overfitting, multicollinearity and human error. A five-factor model offers the same level of accuracy but demonstrated better calibration and clinical performance. Models with a limited number of factors may work better than complex models when applied to a limited number of patients. Copyright (c) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  17. Accuracy comparison among different machine learning techniques for detecting malicious codes

    NASA Astrophysics Data System (ADS)

    Narang, Komal

    2016-03-01

    In this paper, a machine learning based model for malware detection is proposed. It can detect newly released malware i.e. zero day attack by analyzing operation codes on Android operating system. The accuracy of Naïve Bayes, Support Vector Machine (SVM) and Neural Network for detecting malicious code has been compared for the proposed model. In the experiment 400 benign files, 100 system files and 500 malicious files have been used to construct the model. The model yields the best accuracy 88.9% when neural network is used as classifier and achieved 95% and 82.8% accuracy for sensitivity and specificity respectively.

  18. Switch for Good Community Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crawford, Tabitha; Amran, Martha

    2013-11-19

    Switch4Good is an energy-savings program that helps residents reduce consumption from behavior changes; it was co-developed by Balfour Beatty Military Housing Management (BB) and WattzOn in Phase I of this grant. The program was offered at 11 Navy bases. Three customer engagement strategies were evaluated, and it was found that Digital Nudges (a combination of monthly consumption statements with frequent messaging via text or email) was most cost-effective. The program was delivered on-time and on-budget, and its success is based on the teamwork of local BB staff and the WattzOn team. The following graphic shows Switch4Good “by the numbers”, e.g.more » the scale of operations achieved during Phase I.« less

  19. Inter-arch digital model vs. manual cast measurements: Accuracy and reliability.

    PubMed

    Kiviahde, Heikki; Bukovac, Lea; Jussila, Päivi; Pesonen, Paula; Sipilä, Kirsi; Raustia, Aune; Pirttiniemi, Pertti

    2017-06-28

    The purpose of this study was to evaluate the accuracy and reliability of inter-arch measurements using digital dental models and conventional dental casts. Thirty sets of dental casts with permanent dentition were examined. Manual measurements were done with a digital caliper directly on the dental casts, and digital measurements were made on 3D models by two independent examiners. Intra-class correlation coefficients (ICC), a paired sample t-test or Wilcoxon signed-rank test, and Bland-Altman plots were used to evaluate intra- and inter-examiner error and to determine the accuracy and reliability of the measurements. The ICC values were generally good for manual and excellent for digital measurements. The Bland-Altman plots of all the measurements showed good agreement between the manual and digital methods and excellent inter-examiner agreement using the digital method. Inter-arch occlusal measurements on digital models are accurate and reliable and are superior to manual measurements.

  20. Investigation on Selective Laser Melting AlSi10Mg Cellular Lattice Strut: Molten Pool Morphology, Surface Roughness and Dimensional Accuracy

    PubMed Central

    Han, Xuesong; Zhu, Haihong; Nie, Xiaojia; Wang, Guoqing; Zeng, Xiaoyan

    2018-01-01

    AlSi10Mg inclined struts with angle of 45° were fabricated by selective laser melting (SLM) using different scanning speed and hatch spacing to gain insight into the evolution of the molten pool morphology, surface roughness, and dimensional accuracy. The results show that the average width and depth of the molten pool, the lower surface roughness and dimensional deviation decrease with the increase of scanning speed and hatch spacing. The upper surface roughness is found to be almost constant under different processing parameters. The width and depth of the molten pool on powder-supported zone are larger than that of the molten pool on the solid-supported zone, while the width changes more significantly than that of depth. However, if the scanning speed is high enough, the width and depth of the molten pool and the lower surface roughness almost keep constant as the density is still high. Therefore, high dimensional accuracy and density as well as good surface quality can be achieved simultaneously by using high scanning speed during SLMed cellular lattice strut. PMID:29518900

  1. Good character at school: positive classroom behavior mediates the link between character strengths and school achievement

    PubMed Central

    Wagner, Lisa; Ruch, Willibald

    2015-01-01

    Character strengths have been found to be substantially related to children’s and adolescents’ well-being. Initial evidence suggests that they also matter for school success (e.g., Weber and Ruch, 2012). The present set of two studies aimed at replicating and extending these findings in two different age groups, primary school students (N = 179; mean age = 11.6 years) and secondary school students (N = 199; mean age = 14.4 years). The students completed the VIA-Youth (Values in Action Inventory of Strengths for Youth), a self-report measure of the 24 character strengths in the VIA classification. Their teachers rated the students’ positive behavior in the classroom. Additionally, school achievement was assessed: For the primary school students (Study 1), teachers rated the students’ overall school achievement and for the secondary school students (Study 2), we used their grades as a measure of school achievement. We found that several character strengths were associated with both positive classroom behavior and school achievement. Across both samples, school achievement was correlated with love of learning, perseverance, zest, gratitude, hope, and perspective. The strongest correlations with positive classroom behavior were found for perseverance, self-regulation, prudence, social intelligence, and hope. For both samples, there were indirect effects of some of the character strengths on school achievement through teacher-rated positive classroom behavior. The converging findings from the two samples support the notion that character strengths contribute to positive classroom behavior, which in turn enhances school achievement. Results are discussed in terms of their implications for future research and for school interventions based on character strengths. PMID:26029144

  2. Good character at school: positive classroom behavior mediates the link between character strengths and school achievement.

    PubMed

    Wagner, Lisa; Ruch, Willibald

    2015-01-01

    Character strengths have been found to be substantially related to children's and adolescents' well-being. Initial evidence suggests that they also matter for school success (e.g., Weber and Ruch, 2012). The present set of two studies aimed at replicating and extending these findings in two different age groups, primary school students (N = 179; mean age = 11.6 years) and secondary school students (N = 199; mean age = 14.4 years). The students completed the VIA-Youth (Values in Action Inventory of Strengths for Youth), a self-report measure of the 24 character strengths in the VIA classification. Their teachers rated the students' positive behavior in the classroom. Additionally, school achievement was assessed: For the primary school students (Study 1), teachers rated the students' overall school achievement and for the secondary school students (Study 2), we used their grades as a measure of school achievement. We found that several character strengths were associated with both positive classroom behavior and school achievement. Across both samples, school achievement was correlated with love of learning, perseverance, zest, gratitude, hope, and perspective. The strongest correlations with positive classroom behavior were found for perseverance, self-regulation, prudence, social intelligence, and hope. For both samples, there were indirect effects of some of the character strengths on school achievement through teacher-rated positive classroom behavior. The converging findings from the two samples support the notion that character strengths contribute to positive classroom behavior, which in turn enhances school achievement. Results are discussed in terms of their implications for future research and for school interventions based on character strengths.

  3. A note on the accuracy of spectral method applied to nonlinear conservation laws

    NASA Technical Reports Server (NTRS)

    Shu, Chi-Wang; Wong, Peter S.

    1994-01-01

    Fourier spectral method can achieve exponential accuracy both on the approximation level and for solving partial differential equations if the solutions are analytic. For a linear partial differential equation with a discontinuous solution, Fourier spectral method produces poor point-wise accuracy without post-processing, but still maintains exponential accuracy for all moments against analytic functions. In this note we assess the accuracy of Fourier spectral method applied to nonlinear conservation laws through a numerical case study. We find that the moments with respect to analytic functions are no longer very accurate. However the numerical solution does contain accurate information which can be extracted by a post-processing based on Gegenbauer polynomials.

  4. The relative trending accuracy of noninvasive continuous hemoglobin monitoring during hemodialysis in critically ill patients.

    PubMed

    Yamada, Hiroshi; Saeki, Minako; Ito, Junko; Kawada, Kazuhiro; Higurashi, Aya; Funakoshi, Hiromi; Takeda, Kohji

    2015-02-01

    The pulse CO-Oximeter (Radical-7; Masimo Corp., Irvine, CA) is a multi-wavelength spectrophotometric method for noninvasive continuous monitoring of hemoglobin (SpHb). Because evaluating the relative change in blood volume (ΔBV) is crucial to avoid hypovolemia and hypotension during hemodialysis, it would be of great clinical benefit if ΔBV could be estimated by measurement of SpHb during hemodialysis. The capability of the pulse CO-Oximeter to monitor ΔBV depends on the relative trending accuracy of SpHb. The purpose of the current study was to evaluate the relative trending accuracy of SpHb by the pulse CO-Oximeter using Crit-Line as a reference device. In 12 patients who received hemodialysis (total 22 sessions) in the intensive care unit, ΔBV was determined from SpHb. Relative changes in blood volume determined from SpHb were calculated according to the equation: ΔBV(SpHb)=[starting SpHb]/[current SpHb] - 1. The absolute values of SpHb and hematocrit measured by Crit-Line (CL-Hct) showed poor correlation. On the contrary, linear regression analysis showed good correlation between ΔBV(SpHb) and the relative change in blood volume measured by Crit-Line [ΔBV(CL-Hct)] (r=0.83; P≤0.001). Bland-Altman analysis also revealed good agreement between ΔBV(SpHb) and ΔBV(CL-Hct) (bias, -0.77%; precision, 3.41%). Polar plot analysis revealed good relative trending accuracy of SpHb with an angular bias of 4.1° and radial limits of agreement of 24.4° (upper) and -16.2° (lower). The results of the current study indicate that SpHb measurement with the pulse CO-Oximeter has good relative trending accuracy.

  5. "Battleship Numberline": A Digital Game for Improving Estimation Accuracy on Fraction Number Lines

    ERIC Educational Resources Information Center

    Lomas, Derek; Ching, Dixie; Stampfer, Eliane; Sandoval, Melanie; Koedinger, Ken

    2011-01-01

    Given the strong relationship between number line estimation accuracy and math achievement, might a computer-based number line game help improve math achievement? In one study by Rittle-Johnson, Siegler and Alibali (2001), a simple digital game called "Catch the Monster" provided practice in estimating the location of decimals on a…

  6. Muscular and Aerobic Fitness, Working Memory, and Academic Achievement in Children.

    PubMed

    Kao, Shih-Chun; Westfall, Daniel R; Parks, Andrew C; Pontifex, Matthew B; Hillman, Charles H

    2017-03-01

    This study investigated the relationship between aerobic and muscular fitness with working memory and academic achievement in preadolescent children. Seventy-nine 9- to 11-yr-old children completed an aerobic fitness assessment using a graded exercise test; a muscular fitness assessment consisting of upper body, lower body, and core exercises; a serial n-back task to assess working memory; and an academic achievement test of mathematics and reading. Hierarchical regression analyses indicated that after controlling for demographic variables (age, sex, grade, IQ, socioeconomic status), aerobic fitness was associated with greater response accuracy and d' in the 2-back condition and increased mathematic performance in algebraic functions. Muscular fitness was associated with increased response accuracy and d', and longer reaction time in the 2-back condition. Further, the associations of muscular fitness with response accuracy and d' in the 2-back condition were independent of aerobic fitness. The current findings suggest the differential relationships between the aerobic and the muscular aspects of physical fitness with working memory and academic achievement. With the majority of research focusing on childhood health benefits of aerobic fitness, this study suggests the importance of muscular fitness to cognitive health during preadolescence.

  7. What is stereoscopic vision good for?

    NASA Astrophysics Data System (ADS)

    Read, Jenny C. A.

    2015-03-01

    Stereo vision is a resource-intensive process. Nevertheless, it has evolved in many animals including mammals, birds, amphibians and insects. It must therefore convey significant fitness benefits. It is often assumed that the main benefit is improved accuracy of depth judgments, but camouflage breaking may be as important, particularly in predatory animals. In humans, for the last 150 years, stereo vision has been turned to a new use: helping us reproduce visual reality for artistic purposes. By recreating the different views of a scene seen by the two eyes, stereo achieves unprecedented levels of realism. However, it also has some unexpected effects on viewer experience. The disruption of established mechanisms for interpreting pictures may be one reason why some viewers find stereoscopic content disturbing. Stereo vision also has uses in ophthalmology. Clinical stereoacuity tests are used in the management of conditions such as strabismus and amblyopia as well as vision screening. Stereoacuity can reveal the effectiveness of therapy and even predict long-term outcomes post surgery. Yet current clinical stereo tests fall far short of the accuracy and precision achievable in the lab. At Newcastle University, we are exploiting the recent availability of autostereo 3D tablet computers to design a clinical stereotest app in the form of a game suitable for young children. Our goal is to enable quick, accurate and precise stereoacuity measures which will enable clinicians to obtain better outcomes for children with visual disorders.

  8. Good Exemplars of Natural Scene Categories Elicit Clearer Patterns than Bad Exemplars but Not Greater BOLD Activity

    PubMed Central

    Torralbo, Ana; Walther, Dirk B.; Chai, Barry; Caddigan, Eamon; Fei-Fei, Li; Beck, Diane M.

    2013-01-01

    Within the range of images that we might categorize as a “beach”, for example, some will be more representative of that category than others. Here we first confirmed that humans could categorize “good” exemplars better than “bad” exemplars of six scene categories and then explored whether brain regions previously implicated in natural scene categorization showed a similar sensitivity to how well an image exemplifies a category. In a behavioral experiment participants were more accurate and faster at categorizing good than bad exemplars of natural scenes. In an fMRI experiment participants passively viewed blocks of good or bad exemplars from the same six categories. A multi-voxel pattern classifier trained to discriminate among category blocks showed higher decoding accuracy for good than bad exemplars in the PPA, RSC and V1. This difference in decoding accuracy cannot be explained by differences in overall BOLD signal, as average BOLD activity was either equivalent or higher for bad than good scenes in these areas. These results provide further evidence that V1, RSC and the PPA not only contain information relevant for natural scene categorization, but their activity patterns mirror the fundamentally graded nature of human categories. Analysis of the image statistics of our good and bad exemplars shows that variability in low-level features and image structure is higher among bad than good exemplars. A simulation of our neuroimaging experiment suggests that such a difference in variance could account for the observed differences in decoding accuracy. These results are consistent with both low-level models of scene categorization and models that build categories around a prototype. PMID:23555588

  9. Diagnostic accuracy for major depression in multiple sclerosis using self-report questionnaires

    PubMed Central

    Fischer, Anja; Fischer, Marcus; Nicholls, Robert A; Lau, Stephanie; Poettgen, Jana; Patas, Kostas; Heesen, Christoph; Gold, Stefan M

    2015-01-01

    Objective Multiple sclerosis and major depressive disorder frequently co-occur but depression often remains undiagnosed in this population. Self-rated depression questionnaires are a good option where clinician-based standardized diagnostics are not feasible. However, there is a paucity of data on diagnostic accuracy of self-report measures for depression in multiple sclerosis (MS). Moreover, head-to-head comparisons of common questionnaires are largely lacking. This could be particularly relevant for high-risk patients with depressive symptoms. Here, we compare the diagnostic accuracy of the Beck Depression Inventory (BDI) and 30-item version of the Inventory of Depressive Symptomatology Self-Rated (IDS-SR30) for major depressive disorder (MSS) against diagnosis by a structured clinical interview. Methods Patients reporting depressive symptoms completed the BDI, the IDS-SR30 and underwent diagnostic assessment (Mini International Neuropsychiatric Interview, M.I.N.I.). Receiver-Operating Characteristic analyses were performed, providing error estimates and false-positive/negative rates of suggested thresholds. Results Data from n = 31 MS patients were available. BDI and IDS-SR30 total score were significantly correlated (r = 0.82). The IDS-SR30total score, cognitive subscore, and BDI showed excellent to good accuracy (area under the curve (AUC) 0.86, 0.91, and 0.85, respectively). Conclusion Both the IDS-SR30 and the BDI are useful to quantify depressive symptoms showing good sensitivity and specificity. The IDS-SR30 cognitive subscale may be useful as a screening tool and to quantify affective/cognitive depressive symptomatology. PMID:26445703

  10. Diagnostic accuracy of refractometry for assessing bovine colostrum quality: A systematic review and meta-analysis.

    PubMed

    Buczinski, S; Vandeweerd, J M

    2016-09-01

    Provision of good quality colostrum [i.e., immunoglobulin G (IgG) concentration ≥50g/L] is the first step toward ensuring proper passive transfer of immunity for young calves. Precise quantification of colostrum IgG levels cannot be easily performed on the farm. Assessment of the refractive index using a Brix scale with a refractometer has been described as being highly correlated with IgG concentration in colostrum. The aim of this study was to perform a systematic review of the diagnostic accuracy of Brix refractometry to diagnose good quality colostrum. From 101 references initially obtain ed, 11 were included in the systematic review meta-analysis representing 4,251 colostrum samples. The prevalence of good colostrum samples with IgG ≥50g/L varied from 67.3 to 92.3% (median 77.9%). Specific estimates of accuracy [sensitivity (Se) and specificity (Sp)] were obtained for different reported cut-points using a hierarchical summary receiver operating characteristic curve model. For the cut-point of 22% (n=8 studies), Se=80.2% (95% CI: 71.1-87.0%) and Sp=82.6% (71.4-90.0%). Decreasing the cut-point to 18% increased Se [96.1% (91.8-98.2%)] and decreased Sp [54.5% (26.9-79.6%)]. Modeling the effect of these Brix accuracy estimates using a stochastic simulation and Bayes theorem showed that a positive result with the 22% Brix cut-point can be used to diagnose good quality colostrum (posttest probability of a good colostrum: 94.3% (90.7-96.9%). The posttest probability of good colostrum with a Brix value <18% was only 22.7% (12.3-39.2%). Based on this study, the 2 cut-points could be alternatively used to select good quality colostrum (sample with Brix ≥22%) or to discard poor quality colostrum (sample with Brix <18%). When sample results are between these 2 values, colostrum supplementation should be considered. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  11. Parts-Per-Billion Mass Measurement Accuracy Achieved through the Combination of Multiple Linear Regression and Automatic Gain Control in a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer

    PubMed Central

    Williams, D. Keith; Muddiman, David C.

    2008-01-01

    Fourier transform ion cyclotron resonance mass spectrometry has the ability to achieve unprecedented mass measurement accuracy (MMA); MMA is one of the most significant attributes of mass spectrometric measurements as it affords extraordinary molecular specificity. However, due to space-charge effects, the achievable MMA significantly depends on the total number of ions trapped in the ICR cell for a particular measurement. Even through the use of automatic gain control (AGC), the total ion population is not constant between spectra. Multiple linear regression calibration in conjunction with AGC is utilized in these experiments to formally account for the differences in total ion population in the ICR cell between the external calibration spectra and experimental spectra. This ability allows for the extension of dynamic range of the instrument while allowing mean MMA values to remain less than 1 ppm. In addition, multiple linear regression calibration is used to account for both differences in total ion population in the ICR cell as well as relative ion abundance of a given species, which also affords mean MMA values at the parts-per-billion level. PMID:17539605

  12. Improved accuracy for finite element structural analysis via an integrated force method

    NASA Technical Reports Server (NTRS)

    Patnaik, S. N.; Hopkins, D. A.; Aiello, R. A.; Berke, L.

    1992-01-01

    A comparative study was carried out to determine the accuracy of finite element analyses based on the stiffness method, a mixed method, and the new integrated force and dual integrated force methods. The numerical results were obtained with the following software: MSC/NASTRAN and ASKA for the stiffness method; an MHOST implementation method for the mixed method; and GIFT for the integrated force methods. The results indicate that on an overall basis, the stiffness and mixed methods present some limitations. The stiffness method generally requires a large number of elements in the model to achieve acceptable accuracy. The MHOST method tends to achieve a higher degree of accuracy for course models than does the stiffness method implemented by MSC/NASTRAN and ASKA. The two integrated force methods, which bestow simultaneous emphasis on stress equilibrium and strain compatibility, yield accurate solutions with fewer elements in a model. The full potential of these new integrated force methods remains largely unexploited, and they hold the promise of spawning new finite element structural analysis tools.

  13. Statistical algorithms improve accuracy of gene fusion detection

    PubMed Central

    Hsieh, Gillian; Bierman, Rob; Szabo, Linda; Lee, Alex Gia; Freeman, Donald E.; Watson, Nathaniel; Sweet-Cordero, E. Alejandro

    2017-01-01

    Abstract Gene fusions are known to play critical roles in tumor pathogenesis. Yet, sensitive and specific algorithms to detect gene fusions in cancer do not currently exist. In this paper, we present a new statistical algorithm, MACHETE (Mismatched Alignment CHimEra Tracking Engine), which achieves highly sensitive and specific detection of gene fusions from RNA-Seq data, including the highest Positive Predictive Value (PPV) compared to the current state-of-the-art, as assessed in simulated data. We show that the best performing published algorithms either find large numbers of fusions in negative control data or suffer from low sensitivity detecting known driving fusions in gold standard settings, such as EWSR1-FLI1. As proof of principle that MACHETE discovers novel gene fusions with high accuracy in vivo, we mined public data to discover and subsequently PCR validate novel gene fusions missed by other algorithms in the ovarian cancer cell line OVCAR3. These results highlight the gains in accuracy achieved by introducing statistical models into fusion detection, and pave the way for unbiased discovery of potentially driving and druggable gene fusions in primary tumors. PMID:28541529

  14. Competition in Healthcare: Good, Bad or Ugly?

    PubMed Central

    Goddard, Maria

    2015-01-01

    The role of competition in healthcare is much debated. Despite a wealth of international experience in relation to competition, evidence is mixed and contested and the debate about the potential role for competition is often polarised. This paper considers briefly some of the reasons for this, focusing on what is meant by "competition in healthcare" and why it is more valuable to think about the circumstances in which competition is more and less likely to be a good tool to achieve benefits, rather than whether or not it is "good" or "bad," per se.M PMID:26340484

  15. Vocal Accuracy and Neural Plasticity Following Micromelody-Discrimination Training

    PubMed Central

    Zarate, Jean Mary; Delhommeau, Karine; Wood, Sean; Zatorre, Robert J.

    2010-01-01

    Background Recent behavioral studies report correlational evidence to suggest that non-musicians with good pitch discrimination sing more accurately than those with poorer auditory skills. However, other studies have reported a dissociation between perceptual and vocal production skills. In order to elucidate the relationship between auditory discrimination skills and vocal accuracy, we administered an auditory-discrimination training paradigm to a group of non-musicians to determine whether training-enhanced auditory discrimination would specifically result in improved vocal accuracy. Methodology/Principal Findings We utilized micromelodies (i.e., melodies with seven different interval scales, each smaller than a semitone) as the main stimuli for auditory discrimination training and testing, and we used single-note and melodic singing tasks to assess vocal accuracy in two groups of non-musicians (experimental and control). To determine if any training-induced improvements in vocal accuracy would be accompanied by related modulations in cortical activity during singing, the experimental group of non-musicians also performed the singing tasks while undergoing functional magnetic resonance imaging (fMRI). Following training, the experimental group exhibited significant enhancements in micromelody discrimination compared to controls. However, we did not observe a correlated improvement in vocal accuracy during single-note or melodic singing, nor did we detect any training-induced changes in activity within brain regions associated with singing. Conclusions/Significance Given the observations from our auditory training regimen, we therefore conclude that perceptual discrimination training alone is not sufficient to improve vocal accuracy in non-musicians, supporting the suggested dissociation between auditory perception and vocal production. PMID:20567521

  16. Martial arts striking hand peak acceleration, accuracy and consistency.

    PubMed

    Neto, Osmar Pinto; Marzullo, Ana Carolina De Miranda; Bolander, Richard P; Bir, Cynthia A

    2013-01-01

    The goal of this paper was to investigate the possible trade-off between peak hand acceleration and accuracy and consistency of hand strikes performed by martial artists of different training experiences. Ten male martial artists with training experience ranging from one to nine years volunteered to participate in the experiment. Each participant performed 12 maximum effort goal-directed strikes. Hand acceleration during the strikes was obtained using a tri-axial accelerometer block. A pressure sensor matrix was used to determine the accuracy and consistency of the strikes. Accuracy was estimated by the radial distance between the centroid of each subject's 12 strikes and the target, whereas consistency was estimated by the square root of the 12 strikes mean squared distance from their centroid. We found that training experience was significantly correlated to hand peak acceleration prior to impact (r(2)=0.456, p =0.032) and accuracy (r(2)=0. 621, p=0.012). These correlations suggest that more experienced participants exhibited higher hand peak accelerations and at the same time were more accurate. Training experience, however, was not correlated to consistency (r(2)=0.085, p=0.413). Overall, our results suggest that martial arts training may lead practitioners to achieve higher striking hand accelerations with better accuracy and no change in striking consistency.

  17. Research on effect of rough surface on FMCW laser radar range accuracy

    NASA Astrophysics Data System (ADS)

    Tao, Huirong

    2018-03-01

    The non-cooperative targets large scale measurement system based on frequency-modulated continuous-wave (FMCW) laser detection and ranging technology has broad application prospects. It is easy to automate measurement without cooperative targets. However, the complexity and diversity of the surface characteristics of the measured surface directly affects the measurement accuracy. First, the theoretical analysis of range accuracy for a FMCW laser radar was studied, the relationship between surface reflectivity and accuracy was obtained. Then, to verify the effect of surface reflectance for ranging accuracy, a standard tool ball and three standard roughness samples were measured within 7 m to 24 m. The uncertainty of each target was obtained. The results show that the measurement accuracy is found to increase as the surface reflectivity gets larger. Good agreements were obtained between theoretical analysis and measurements from rough surfaces. Otherwise, when the laser spot diameter is smaller than the surface correlation length, a multi-point averaged measurement can reduce the measurement uncertainty. The experimental results show that this method is feasible.

  18. High accuracy wavelength calibration for a scanning visible spectrometer.

    PubMed

    Scotti, Filippo; Bell, Ronald E

    2010-10-01

    Spectroscopic applications for plasma velocity measurements often require wavelength accuracies ≤0.2 Å. An automated calibration, which is stable over time and environmental conditions without the need to recalibrate after each grating movement, was developed for a scanning spectrometer to achieve high wavelength accuracy over the visible spectrum. This method fits all relevant spectrometer parameters using multiple calibration spectra. With a stepping-motor controlled sine drive, an accuracy of ∼0.25 Å has been demonstrated. With the addition of a high resolution (0.075 arc  sec) optical encoder on the grating stage, greater precision (∼0.005 Å) is possible, allowing absolute velocity measurements within ∼0.3 km/s. This level of precision requires monitoring of atmospheric temperature and pressure and of grating bulk temperature to correct for changes in the refractive index of air and the groove density, respectively.

  19. Performance of search strategies to retrieve systematic reviews of diagnostic test accuracy from the Cochrane Library.

    PubMed

    Huang, Yuansheng; Yang, Zhirong; Wang, Jing; Zhuo, Lin; Li, Zhixia; Zhan, Siyan

    2016-05-06

    To compare the performance of search strategies to retrieve systematic reviews of diagnostic test accuracy from The Cochrane Library. Databases of CDSR and DARE in the Cochrane Library were searched for systematic reviews of diagnostic test accuracy published between 2008 and 2012 through nine search strategies. Each strategy consists of one group or combination of groups of searching filters about diagnostic test accuracy. Four groups of diagnostic filters were used. The Strategy combing all the filters was used as the reference to determine the sensitivity, precision, and the sensitivity x precision product for another eight Strategies. The reference Strategy retrieved 8029 records, of which 832 were eligible. The strategy only composed of MeSH terms about "accuracy measures" achieved the highest values in both precision (69.71%) and product (52.45%) with a moderate sensitivity (75.24%). The combination of MeSH terms and free text words about "accuracy measures" contributed little to increasing the sensitivity. Strategies composed of filters about "diagnosis" had similar sensitivity but lower precision and product to those composed of filters about "accuracy measures". MeSH term "exp'diagnosis' " achieved the lowest precision (9.78%) and product (7.91%), while its hyponym retrieved only half the number of records at the expense of missing 53 target articles. The precision was negatively correlated with sensitivities among the nine strategies. Compared to the filters about "diagnosis", the filters about "accuracy measures" achieved similar sensitivities but higher precision. When combining both terms, sensitivity of the strategy was enhanced obviously. The combination of MeSH terms and free text words about the same concept seemed to be meaningless for enhancing sensitivity. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  20. An optical lattice clock with accuracy and stability at the 10(-18) level.

    PubMed

    Bloom, B J; Nicholson, T L; Williams, J R; Campbell, S L; Bishof, M; Zhang, X; Zhang, W; Bromley, S L; Ye, J

    2014-02-06

    Progress in atomic, optical and quantum science has led to rapid improvements in atomic clocks. At the same time, atomic clock research has helped to advance the frontiers of science, affecting both fundamental and applied research. The ability to control quantum states of individual atoms and photons is central to quantum information science and precision measurement, and optical clocks based on single ions have achieved the lowest systematic uncertainty of any frequency standard. Although many-atom lattice clocks have shown advantages in measurement precision over trapped-ion clocks, their accuracy has remained 16 times worse. Here we demonstrate a many-atom system that achieves an accuracy of 6.4 × 10(-18), which is not only better than a single-ion-based clock, but also reduces the required measurement time by two orders of magnitude. By systematically evaluating all known sources of uncertainty, including in situ monitoring of the blackbody radiation environment, we improve the accuracy of optical lattice clocks by a factor of 22. This single clock has simultaneously achieved the best known performance in the key characteristics necessary for consideration as a primary standard-stability and accuracy. More stable and accurate atomic clocks will benefit a wide range of fields, such as the realization and distribution of SI units, the search for time variation of fundamental constants, clock-based geodesy and other precision tests of the fundamental laws of nature. This work also connects to the development of quantum sensors and many-body quantum state engineering (such as spin squeezing) to advance measurement precision beyond the standard quantum limit.

  1. Effects of accuracy motivation and anchoring on metacomprehension judgment and accuracy.

    PubMed

    Zhao, Qin

    2012-01-01

    The current research investigates how accuracy motivation impacts anchoring and adjustment in metacomprehension judgment and how accuracy motivation and anchoring affect metacomprehension accuracy. Participants were randomly assigned to one of six conditions produced by the between-subjects factorial design involving accuracy motivation (incentive or no) and peer performance anchor (95%, 55%, or no). Two studies showed that accuracy motivation did not impact anchoring bias, but the adjustment-from-anchor process occurred. Accuracy incentive increased anchor-judgment gap for the 95% anchor but not for the 55% anchor, which induced less certainty about the direction of adjustment. The findings offer support to the integrative theory of anchoring. Additionally, the two studies revealed a "power struggle" between accuracy motivation and anchoring in influencing metacomprehension accuracy. Accuracy motivation could improve metacomprehension accuracy in spite of anchoring effect, but if anchoring effect is too strong, it could overpower the motivation effect. The implications of the findings were discussed.

  2. Vibrationally averaged post Born-Oppenheimer isotopic dipole moment calculations approaching spectroscopic accuracy.

    PubMed

    Arapiraca, A F C; Jonsson, Dan; Mohallem, J R

    2011-12-28

    We report an upgrade of the Dalton code to include post Born-Oppenheimer nuclear mass corrections in the calculations of (ro-)vibrational averages of molecular properties. These corrections are necessary to achieve an accuracy of 10(-4) debye in the calculations of isotopic dipole moments. Calculations on the self-consistent field level present this accuracy, while numerical instabilities compromise correlated calculations. Applications to HD, ethane, and ethylene isotopologues are implemented, all of them approaching the experimental values.

  3. Meta-analysis of stratus OCT glaucoma diagnostic accuracy.

    PubMed

    Chen, Hsin-Yi; Chang, Yue-Cune

    2014-09-01

    To evaluate the diagnostic accuracy of glaucoma in different stages, different types of glaucoma, and different ethnic groups using Stratus optical coherence tomography (OCT). We searched MEDLINE to identify available articles on diagnostic accuracy of glaucoma published between January 2004 and December 2011. A PubMed (National Center for Biotechnology Information) search using medical subject headings and keywords was executed using the following terms: "diagnostic accuracy" or "receiver operator characteristic" or "area under curve" or "AUC" and "Stratus OCT" and "glaucoma." The search was subsequently limited to publications in English. The area under a receiver operator characteristic (AUC) curve was used to measure the diagnostic performance. A random-effects model was used to estimate the pooled AUC value of the 17 parameters (average retinal nerve fiber layer thickness, temporal quadrant, superior quadrant, nasal quadrant, inferior quadrant, and 1 to 12 o'clock). Meta-regression analysis was used to check the significance of some important factors: (1) glaucoma severity (five stages), (2) glaucoma types (four types), and (3) ethnicity (four categories). The orders of accuracy among those parameters were as follows: average > inferior > superior > 7 o'clock > 6 o'clock > 11 o'clock > 12 o'clock > 1 o'clock > 5 o'clock > nasal > temporal > 2 o'clock > 10 o'clock > 8 o'clock > 9 o'clock > 4 o'clock > 3 o'clock. After adjusting for the effects of age, glaucoma severity, glaucoma types, and ethnicity, the average retinal nerve fiber layer thickness provided highest accuracy compared with the other parameters of OCT. The diagnostic accuracy in Asian populations was significantly lower than that in whites and the other two ethnic types. Stratus OCT demonstrated good diagnostic capability in differentiating glaucomatous from normal eyes. However, we should be more cautious in applying this instrument in Asian groups in glaucoma management.

  4. Constructing better classifier ensemble based on weighted accuracy and diversity measure.

    PubMed

    Zeng, Xiaodong; Wong, Derek F; Chao, Lidia S

    2014-01-01

    A weighted accuracy and diversity (WAD) method is presented, a novel measure used to evaluate the quality of the classifier ensemble, assisting in the ensemble selection task. The proposed measure is motivated by a commonly accepted hypothesis; that is, a robust classifier ensemble should not only be accurate but also different from every other member. In fact, accuracy and diversity are mutual restraint factors; that is, an ensemble with high accuracy may have low diversity, and an overly diverse ensemble may negatively affect accuracy. This study proposes a method to find the balance between accuracy and diversity that enhances the predictive ability of an ensemble for unknown data. The quality assessment for an ensemble is performed such that the final score is achieved by computing the harmonic mean of accuracy and diversity, where two weight parameters are used to balance them. The measure is compared to two representative measures, Kappa-Error and GenDiv, and two threshold measures that consider only accuracy or diversity, with two heuristic search algorithms, genetic algorithm, and forward hill-climbing algorithm, in ensemble selection tasks performed on 15 UCI benchmark datasets. The empirical results demonstrate that the WAD measure is superior to others in most cases.

  5. Constructing Better Classifier Ensemble Based on Weighted Accuracy and Diversity Measure

    PubMed Central

    Chao, Lidia S.

    2014-01-01

    A weighted accuracy and diversity (WAD) method is presented, a novel measure used to evaluate the quality of the classifier ensemble, assisting in the ensemble selection task. The proposed measure is motivated by a commonly accepted hypothesis; that is, a robust classifier ensemble should not only be accurate but also different from every other member. In fact, accuracy and diversity are mutual restraint factors; that is, an ensemble with high accuracy may have low diversity, and an overly diverse ensemble may negatively affect accuracy. This study proposes a method to find the balance between accuracy and diversity that enhances the predictive ability of an ensemble for unknown data. The quality assessment for an ensemble is performed such that the final score is achieved by computing the harmonic mean of accuracy and diversity, where two weight parameters are used to balance them. The measure is compared to two representative measures, Kappa-Error and GenDiv, and two threshold measures that consider only accuracy or diversity, with two heuristic search algorithms, genetic algorithm, and forward hill-climbing algorithm, in ensemble selection tasks performed on 15 UCI benchmark datasets. The empirical results demonstrate that the WAD measure is superior to others in most cases. PMID:24672402

  6. A New Three-Dimensional High-Accuracy Automatic Alignment System For Single-Mode Fibers

    NASA Astrophysics Data System (ADS)

    Yun-jiang, Rao; Shang-lian, Huang; Ping, Li; Yu-mei, Wen; Jun, Tang

    1990-02-01

    In order to achieve the low-loss splices of single-mode fibers, a new three-dimension high-accuracy automatic alignment system for single -mode fibers has been developed, which includes a new-type three-dimension high-resolution microdisplacement servo stage driven by piezoelectric elements, a new high-accuracy measurement system for the misalignment error of the fiber core-axis, and a special single chip microcomputer processing system. The experimental results show that alignment accuracy of ±0.1 pin with a movable stroke of -±20μm has been obtained. This new system has more advantages than that reported.

  7. Improved Accuracy of the Inherent Shrinkage Method for Fast and More Reliable Welding Distortion Calculations

    NASA Astrophysics Data System (ADS)

    Mendizabal, A.; González-Díaz, J. B.; San Sebastián, M.; Echeverría, A.

    2016-07-01

    This paper describes the implementation of a simple strategy adopted for the inherent shrinkage method (ISM) to predict welding-induced distortion. This strategy not only makes it possible for the ISM to reach accuracy levels similar to the detailed transient analysis method (considered the most reliable technique for calculating welding distortion) but also significantly reduces the time required for these types of calculations. This strategy is based on the sequential activation of welding blocks to account for welding direction and transient movement of the heat source. As a result, a significant improvement in distortion prediction is achieved. This is demonstrated by experimentally measuring and numerically analyzing distortions in two case studies: a vane segment subassembly of an aero-engine, represented with 3D-solid elements, and a car body component, represented with 3D-shell elements. The proposed strategy proves to be a good alternative for quickly estimating the correct behaviors of large welded components and may have important practical applications in the manufacturing industry.

  8. The influence of achievement goals on the constructive activity of low achievers during collaborative problem solving.

    PubMed

    Gabriele, Anthony J

    2007-03-01

    Previous research on small-group learning has found that level of constructive activity (solving or explaining how to solve problems using ideas stated or implied in the explanation provided by a partner) was a better predictor of post-test achievement than either a student's prior achievement or the quality of help received (Webb, Troper, & Fall, 1995). The purpose of this study was to extend this research by examining the influence of additional factors, in particular, achievement goals and comprehension monitoring, on low achieving students' constructive activity after receiving help from a high achieving peer. Thirty-two low achieving upper elementary students from an urban school district in the mid-west of the United States were paired with high achieving partners. Videotape data from a previously reported study on peer collaboration were transcribed and reanalyzed. In that study, dyads were randomly assigned instructions designed to induce either a learning or performance goal and were videotaped as they worked together to solve a set of mathematical word problems. The following day, students were individually post-tested on problems similar to the ones worked on in pairs. Consistent with previous research, low achieving students' level of constructive activity predicted post-test performance. In addition, constructive activity was found to mediate the relationship between achievement goals and learning. However, achievement goals were not related to low achievers constructive use of help. Instead, achievement goals were related to low achievers' relative accuracy in comprehension monitoring, which in turn was related to level of constructive activity. The meaning of these results for understanding the processes by which low achievers learn from peer help and implications for classroom practice are discussed.

  9. QUADAS and STARD: evaluating the quality of diagnostic accuracy studies.

    PubMed

    Oliveira, Maria Regina Fernandes de; Gomes, Almério de Castro; Toscano, Cristiana Maria

    2011-04-01

    To compare the performance of two approaches, one based on the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) and another on the Standards for Reporting Studies of Diagnostic Accuracy (STARD), in evaluating the quality of studies validating the OptiMal® rapid malaria diagnostic test. Articles validating the rapid test published until 2007 were searched in the Medline/PubMed database. This search retrieved 13 articles. A combination of 12 QUADAS criteria and three STARD criteria were compared with the 12 QUADAS criteria alone. Articles that fulfilled at least 50% of QUADAS criteria were considered as regular to good quality. Of the 13 articles retrieved, 12 fulfilled at least 50% of QUADAS criteria, and only two fulfilled the STARD/QUADAS criteria combined. Considering the two criteria combination (> 6 QUADAS and > 3 STARD), two studies (15.4%) showed good methodological quality. The articles selection using the proposed combination resulted in two to eight articles, depending on the number of items assumed as cutoff point. The STARD/QUADAS combination has the potential to provide greater rigor when evaluating the quality of studies validating malaria diagnostic tests, given that it incorporates relevant information not contemplated in the QUADAS criteria alone.

  10. Spectroscopy of H3+ based on a new high-accuracy global potential energy surface.

    PubMed

    Polyansky, Oleg L; Alijah, Alexander; Zobov, Nikolai F; Mizus, Irina I; Ovsyannikov, Roman I; Tennyson, Jonathan; Lodi, Lorenzo; Szidarovszky, Tamás; Császár, Attila G

    2012-11-13

    The molecular ion H(3)(+) is the simplest polyatomic and poly-electronic molecular system, and its spectrum constitutes an important benchmark for which precise answers can be obtained ab initio from the equations of quantum mechanics. Significant progress in the computation of the ro-vibrational spectrum of H(3)(+) is discussed. A new, global potential energy surface (PES) based on ab initio points computed with an average accuracy of 0.01 cm(-1) relative to the non-relativistic limit has recently been constructed. An analytical representation of these points is provided, exhibiting a standard deviation of 0.097 cm(-1). Problems with earlier fits are discussed. The new PES is used for the computation of transition frequencies. Recently measured lines at visible wavelengths combined with previously determined infrared ro-vibrational data show that an accuracy of the order of 0.1 cm(-1) is achieved by these computations. In order to achieve this degree of accuracy, relativistic, adiabatic and non-adiabatic effects must be properly accounted for. The accuracy of these calculations facilitates the reassignment of some measured lines, further reducing the standard deviation between experiment and theory.

  11. 'It's a matter of patient safety': understanding challenges in everyday clinical practice for achieving good care on the surgical ward - a qualitative study.

    PubMed

    Jangland, Eva; Nyberg, Berit; Yngman-Uhlin, Pia

    2017-06-01

    Surgical care plays an important role in the acute hospital's delivery of safe, high-quality patient care. Although demands for effectiveness are high in surgical wards quality of care and patient safety must also be secured. It is therefore necessary to identify the challenges and barriers linked to quality of care and patient safety with a focus on this specific setting. To explore situations and processes that support or hinder good safe patient care on the surgical ward. This qualitative study was based on a strategic sample of 10 department and ward leaders in three hospitals and six surgical wards in Sweden. Repeated reflective interviews were analysed using systematic text condensation. Four themes described the leaders' view of a complex healthcare setting that demands effectiveness and efficiency in moving patients quickly through the healthcare system. Quality of care and patient safety were often hampered factors such as a shift of care level, with critically ill patients cared for without reorganisation of nurses' competencies on the surgical ward. There is a gap between what is described in written documents and what is or can be performed in clinical practice to achieve good care and safe care on the surgical ward. A shift in levels of care on the surgical ward without reallocation of the necessary competencies at the patient's bedside show consequences for quality of care and patient safety. This means that surgical wards should consider reviewing their organisation and implementing more advanced nursing roles in direct patient care on all shifts. The ethical issues and the moral stress on nurses who lack the resources and competence to deliver good care according to professional values need to be made more explicit as a part of the patient safety agenda in the surgical ward. © 2016 Nordic College of Caring Science.

  12. The Effect of Moderate and High-Intensity Fatigue on Groundstroke Accuracy in Expert and Non-Expert Tennis Players

    PubMed Central

    Lyons, Mark; Al-Nakeeb, Yahya; Hankey, Joanne; Nevill, Alan

    2013-01-01

    Exploring the effects of fatigue on skilled performance in tennis presents a significant challenge to the researcher with respect to ecological validity. This study examined the effects of moderate and high-intensity fatigue on groundstroke accuracy in expert and non-expert tennis players. The research also explored whether the effects of fatigue are the same regardless of gender and player’s achievement motivation characteristics. 13 expert (7 male, 6 female) and 17 non-expert (13 male, 4 female) tennis players participated in the study. Groundstroke accuracy was assessed using the modified Loughborough Tennis Skills Test. Fatigue was induced using the Loughborough Intermittent Tennis Test with moderate (70%) and high-intensities (90%) set as a percentage of peak heart rate (attained during a tennis-specific maximal hitting sprint test). Ratings of perceived exertion were used as an adjunct to the monitoring of heart rate. Achievement goal indicators for each player were assessed using the 2 x 2 Achievement Goals Questionnaire for Sport in an effort to examine if this personality characteristic provides insight into how players perform under moderate and high-intensity fatigue conditions. A series of mixed ANOVA’s revealed significant fatigue effects on groundstroke accuracy regardless of expertise. The expert players however, maintained better groundstroke accuracy across all conditions compared to the novice players. Nevertheless, in both groups, performance following high-intensity fatigue deteriorated compared to performance at rest and performance while moderately fatigued. Groundstroke accuracy under moderate levels of fatigue was equivalent to that at rest. Fatigue effects were also similar regardless of gender. No fatigue by expertise, or fatigue by gender interactions were found. Fatigue effects were also equivalent regardless of player’s achievement goal indicators. Future research is required to explore the effects of fatigue on performance in

  13. Accuracy and borehole influences in pulsed neutron gamma density logging while drilling.

    PubMed

    Yu, Huawei; Sun, Jianmeng; Wang, Jiaxin; Gardner, Robin P

    2011-09-01

    A new pulsed neutron gamma density (NGD) logging has been developed to replace radioactive chemical sources in oil logging tools. The present paper describes studies of near and far density measurement accuracy of NGD logging at two spacings and the borehole influences using Monte-Carlo simulation. The results show that the accuracy of near density is not as good as far density. It is difficult to correct this for borehole effects by using conventional methods because both near and far density measurement is significantly sensitive to standoffs and mud properties. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Role of optics in the accuracy of depth-from-defocus systems: comment.

    PubMed

    Blendowske, Ralf

    2007-10-01

    In their paper "Role of optics in the accuracy of depth-from-defocus systems" [J. Opt. Soc. Am. A24, 967 (2007)] the authors Blayvas, Kimmel, and Rivlin discuss the effect of optics on the depth reconstruction accuracy. To this end they applied an approach in Fourier space. An alternative derivation of their result in the spatial domain, based on geometrical optics, is presented and compared with their outcome. A better agreement with experimental data is achieved if some unclarities are refined.

  15. Relationship between accuracy and complexity when learning underarm precision throwing.

    PubMed

    Valle, Maria Stella; Lombardo, Luciano; Cioni, Matteo; Casabona, Antonino

    2018-06-12

    Learning precision ball throwing was mostly studied to explore the early rapid improvement of accuracy, with poor attention on possible adaptive processes occurring later when the rate of improvement is reduced. Here, we tried to demonstrate that the strategy to select angle, speed and height at ball release can be managed during the learning periods following the performance stabilization. To this aim, we used a multivariate linear model with angle, speed and height as predictors of changes in accuracy. Participants performed underarm throws of a tennis ball to hit a target on the floor, 3.42 m away. Two training sessions (S1, S2) and one retention test were executed. Performance accuracy increased over the S1 and stabilized during the S2, with a rate of changes along the throwing axis slower than along the orthogonal axis. However, both the axes contributed to the performance changes over the learning and consolidation time. A stable relationship between the accuracy and the release parameters was observed only during S2, with a good fraction of the performance variance explained by the combination of speed and height. All the variations were maintained during the retention test. Overall, accuracy improvements and reduction in throwing complexity at the ball release followed separate timing over the course of learning and consolidation.

  16. Improved accuracy for finite element structural analysis via a new integrated force method

    NASA Technical Reports Server (NTRS)

    Patnaik, Surya N.; Hopkins, Dale A.; Aiello, Robert A.; Berke, Laszlo

    1992-01-01

    A comparative study was carried out to determine the accuracy of finite element analyses based on the stiffness method, a mixed method, and the new integrated force and dual integrated force methods. The numerical results were obtained with the following software: MSC/NASTRAN and ASKA for the stiffness method; an MHOST implementation method for the mixed method; and GIFT for the integrated force methods. The results indicate that on an overall basis, the stiffness and mixed methods present some limitations. The stiffness method generally requires a large number of elements in the model to achieve acceptable accuracy. The MHOST method tends to achieve a higher degree of accuracy for course models than does the stiffness method implemented by MSC/NASTRAN and ASKA. The two integrated force methods, which bestow simultaneous emphasis on stress equilibrium and strain compatibility, yield accurate solutions with fewer elements in a model. The full potential of these new integrated force methods remains largely unexploited, and they hold the promise of spawning new finite element structural analysis tools.

  17. A material sensitivity study on the accuracy of deformable organ registration using linear biomechanical models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chi, Y.; Liang, J.; Yan, D.

    2006-02-15

    Model-based deformable organ registration techniques using the finite element method (FEM) have recently been investigated intensively and applied to image-guided adaptive radiotherapy (IGART). These techniques assume that human organs are linearly elastic material, and their mechanical properties are predetermined. Unfortunately, the accurate measurement of the tissue material properties is challenging and the properties usually vary between patients. A common issue is therefore the achievable accuracy of the calculation due to the limited access to tissue elastic material constants. In this study, we performed a systematic investigation on this subject based on tissue biomechanics and computer simulations to establish the relationshipsmore » between achievable registration accuracy and tissue mechanical and organ geometrical properties. Primarily we focused on image registration for three organs: rectal wall, bladder wall, and prostate. The tissue anisotropy due to orientation preference in tissue fiber alignment is captured by using an orthotropic or a transversely isotropic elastic model. First we developed biomechanical models for the rectal wall, bladder wall, and prostate using simplified geometries and investigated the effect of varying material parameters on the resulting organ deformation. Then computer models based on patient image data were constructed, and image registrations were performed. The sensitivity of registration errors was studied by perturbating the tissue material properties from their mean values while fixing the boundary conditions. The simulation results demonstrated that registration error for a subvolume increases as its distance from the boundary increases. Also, a variable associated with material stability was found to be a dominant factor in registration accuracy in the context of material uncertainty. For hollow thin organs such as rectal walls and bladder walls, the registration errors are limited. Given 30% in material

  18. 38 CFR 21.6054 - Criteria for determining good employment potential.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Stabilization of medical conditions or substance abuse problems. (6) Participation in therapeutic work programs... good potential for achieving employment does not exist, a personal interview will be scheduled, and the...

  19. Too Much of a Good Thing: User Leadership at TPAC

    ERIC Educational Resources Information Center

    Connelly, Brett; Dalton, Tashia; Murphy, Derrick; Rosales, Daniel; Sudlow, Daniel; Havelka, Douglas

    2016-01-01

    TPAC is a small third party health claims business that was seeking avenues for revenue growth and opportunities to increase efficiency. One course of action that management selected to achieve these goals was a change in the software application used to process claims. The new application was adopted to increase the speed and accuracy of claims…

  20. The use of low density high accuracy (LDHA) data for correction of high density low accuracy (HDLA) point cloud

    NASA Astrophysics Data System (ADS)

    Rak, Michal Bartosz; Wozniak, Adam; Mayer, J. R. R.

    2016-06-01

    Coordinate measuring techniques rely on computer processing of coordinate values of points gathered from physical surfaces using contact or non-contact methods. Contact measurements are characterized by low density and high accuracy. On the other hand optical methods gather high density data of the whole object in a short time but with accuracy at least one order of magnitude lower than for contact measurements. Thus the drawback of contact methods is low density of data, while for non-contact methods it is low accuracy. In this paper a method for fusion of data from two measurements of fundamentally different nature: high density low accuracy (HDLA) and low density high accuracy (LDHA) is presented to overcome the limitations of both measuring methods. In the proposed method the concept of virtual markers is used to find a representation of pairs of corresponding characteristic points in both sets of data. In each pair the coordinates of the point from contact measurements is treated as a reference for the corresponding point from non-contact measurement. Transformation enabling displacement of characteristic points from optical measurement to their match from contact measurements is determined and applied to the whole point cloud. The efficiency of the proposed algorithm was evaluated by comparison with data from a coordinate measuring machine (CMM). Three surfaces were used for this evaluation: plane, turbine blade and engine cover. For the planar surface the achieved improvement was of around 200 μm. Similar results were obtained for the turbine blade but for the engine cover the improvement was smaller. For both freeform surfaces the improvement was higher for raw data than for data after creation of mesh of triangles.

  1. Improving the Accuracy of the Chebyshev Rational Approximation Method Using Substeps

    DOE PAGES

    Isotalo, Aarno; Pusa, Maria

    2016-05-01

    The Chebyshev Rational Approximation Method (CRAM) for solving the decay and depletion of nuclides is shown to have a remarkable decrease in error when advancing the system with the same time step and microscopic reaction rates as the previous step. This property is exploited here to achieve high accuracy in any end-of-step solution by dividing a step into equidistant sub-steps. The computational cost of identical substeps can be reduced significantly below that of an equal number of regular steps, as the LU decompositions for the linear solves required in CRAM only need to be formed on the first substep. Themore » improved accuracy provided by substeps is most relevant in decay calculations, where there have previously been concerns about the accuracy and generality of CRAM. Lastly, with substeps, CRAM can solve any decay or depletion problem with constant microscopic reaction rates to an extremely high accuracy for all nuclides with concentrations above an arbitrary limit.« less

  2. Camera sensor arrangement for crop/weed detection accuracy in agronomic images.

    PubMed

    Romeo, Juan; Guerrero, José Miguel; Montalvo, Martín; Emmi, Luis; Guijarro, María; Gonzalez-de-Santos, Pablo; Pajares, Gonzalo

    2013-04-02

    In Precision Agriculture, images coming from camera-based sensors are commonly used for weed identification and crop line detection, either to apply specific treatments or for vehicle guidance purposes. Accuracy of identification and detection is an important issue to be addressed in image processing. There are two main types of parameters affecting the accuracy of the images, namely: (a) extrinsic, related to the sensor's positioning in the tractor; (b) intrinsic, related to the sensor specifications, such as CCD resolution, focal length or iris aperture, among others. Moreover, in agricultural applications, the uncontrolled illumination, existing in outdoor environments, is also an important factor affecting the image accuracy. This paper is exclusively focused on two main issues, always with the goal to achieve the highest image accuracy in Precision Agriculture applications, making the following two main contributions: (a) camera sensor arrangement, to adjust extrinsic parameters and (b) design of strategies for controlling the adverse illumination effects.

  3. Adaptive sensor-based ultra-high accuracy solar concentrator tracker

    NASA Astrophysics Data System (ADS)

    Brinkley, Jordyn; Hassanzadeh, Ali

    2017-09-01

    Conventional solar trackers use information of the sun's position, either by direct sensing or by GPS. Our method uses the shading of the receiver. This, coupled with nonimaging optics design allows us to achieve ultra-high concentration. Incorporating a sensor based shadow tracking method with a two stage concentration solar hybrid parabolic trough allows the system to maintain high concentration with acute accuracy.

  4. Sampling Molecular Conformers in Solution with Quantum Mechanical Accuracy at a Nearly Molecular-Mechanics Cost.

    PubMed

    Rosa, Marta; Micciarelli, Marco; Laio, Alessandro; Baroni, Stefano

    2016-09-13

    We introduce a method to evaluate the relative populations of different conformers of molecular species in solution, aiming at quantum mechanical accuracy, while keeping the computational cost at a nearly molecular-mechanics level. This goal is achieved by combining long classical molecular-dynamics simulations to sample the free-energy landscape of the system, advanced clustering techniques to identify the most relevant conformers, and thermodynamic perturbation theory to correct the resulting populations, using quantum-mechanical energies from density functional theory. A quantitative criterion for assessing the accuracy thus achieved is proposed. The resulting methodology is demonstrated in the specific case of cyanin (cyanidin-3-glucoside) in water solution.

  5. Cultivating Hope through Learning for the Common Good

    ERIC Educational Resources Information Center

    McEwen, Rhonda M.; Herman, Wayne R.; Himes, Brant M.

    2016-01-01

    This article examines how an orientation toward "hope" can guide institutions of higher education in achieving their ultimate purpose of providing education for the common good of society. In today's cultural context, colleges and universities must navigate a multitude of challenges and competing philosophies, many of which question the…

  6. Revealing how network structure affects accuracy of link prediction

    NASA Astrophysics Data System (ADS)

    Yang, Jin-Xuan; Zhang, Xiao-Dong

    2017-08-01

    Link prediction plays an important role in network reconstruction and network evolution. The network structure affects the accuracy of link prediction, which is an interesting problem. In this paper we use common neighbors and the Gini coefficient to reveal the relation between them, which can provide a good reference for the choice of a suitable link prediction algorithm according to the network structure. Moreover, the statistical analysis reveals correlation between the common neighbors index, Gini coefficient index and other indices to describe the network structure, such as Laplacian eigenvalues, clustering coefficient, degree heterogeneity, and assortativity of network. Furthermore, a new method to predict missing links is proposed. The experimental results show that the proposed algorithm yields better prediction accuracy and robustness to the network structure than existing currently used methods for a variety of real-world networks.

  7. The Role of Feedback on Studying, Achievement and Calibration.

    ERIC Educational Resources Information Center

    Chu, Stephanie T. L.; Jamieson-Noel, Dianne L.; Winne, Philip H.

    One set of hypotheses examined in this study was that various types of feedback (outcome, process, and corrective) supply different information about performance and have different effects on studying processes and on achievement. Another set of hypotheses concerned students' calibration, their accuracy in predicting and postdicting achievement…

  8. Good work - how is it recognised by the nurse?

    PubMed

    Christiansen, Bjørg

    2008-06-01

    The aim of this paper is to shed light on how nurses describe situations that reflect achievement and provide confirmation that they have done good work. Nurses' recognition of good work does not seem to have been the object of direct investigation, but is indirectly reflected in studies focusing on nurses' perceptions on work environments and the multifaceted nature of nursing. However, acknowledging high-quality performance in professional nurses can facilitate nurses in maintaining and strengthening the goals and values of the profession. This in turn can help nurses shoulder the multifaceted responsibilities they have to patients and next of kin. This paper is part of the Professional Learning in a Changing Society project, Institute of Educational Research, University of Oslo, funded by the Research Council of Norway. The project involves four professional groups. This paper, however, focuses on a group of 10 nurses, nine of whom work in hospitals and one in an outpatient clinic. A qualitative approach was chosen to gain insight into how nurses, as well as the other professional groups in the project, engage in processes of knowledge production and quality assurance work. Data presented in this paper derive from semi-structured in-depth interviews conducted during spring 2005 and focuses on the recognition of good work. The following themes were identified as essential in confirming that one did good work: securing fundamental needs of patients and next of kin; managing the flow of responsibilities; positive feedback. CONCLUSIONS. Good work seems to be related to specific situations and a sense of achievement by the respondents. Recognition of good work is not only rewarding and enjoyable; it may also serve as a source of consciousness raising for professional and ethical guidelines in the work place.

  9. What Good is Raman Water Vapor Lidar?

    NASA Technical Reports Server (NTRS)

    Whitman, David

    2011-01-01

    Raman lidar has been used to quantify water vapor in the atmosphere for various scientific studies including mesoscale meteorology and satellite validation. Now the international networks of NDACC and GRUAN have interest in using Raman water vapor lidar for detecting trends in atmospheric water vapor concentrations. What are the data needs for addressing these very different measurement challenges. We will review briefly the scientific needs for water vapor accuracy for each of these three applications and attempt to translate that into performance specifications for Raman lidar in an effort to address the question in the title of "What good is Raman water vapor Iidar."

  10. Solving Nonlinear Euler Equations with Arbitrary Accuracy

    NASA Technical Reports Server (NTRS)

    Dyson, Rodger W.

    2005-01-01

    A computer program that efficiently solves the time-dependent, nonlinear Euler equations in two dimensions to an arbitrarily high order of accuracy has been developed. The program implements a modified form of a prior arbitrary- accuracy simulation algorithm that is a member of the class of algorithms known in the art as modified expansion solution approximation (MESA) schemes. Whereas millions of lines of code were needed to implement the prior MESA algorithm, it is possible to implement the present MESA algorithm by use of one or a few pages of Fortran code, the exact amount depending on the specific application. The ability to solve the Euler equations to arbitrarily high accuracy is especially beneficial in simulations of aeroacoustic effects in settings in which fully nonlinear behavior is expected - for example, at stagnation points of fan blades, where linearizing assumptions break down. At these locations, it is necessary to solve the full nonlinear Euler equations, and inasmuch as the acoustical energy is of the order of 4 to 5 orders of magnitude below that of the mean flow, it is necessary to achieve an overall fractional error of less than 10-6 in order to faithfully simulate entropy, vortical, and acoustical waves.

  11. Evaluation of diagnostic accuracy in detecting ordered symptom statuses without a gold standard

    PubMed Central

    Wang, Zheyu; Zhou, Xiao-Hua; Wang, Miqu

    2011-01-01

    Our research is motivated by 2 methodological problems in assessing diagnostic accuracy of traditional Chinese medicine (TCM) doctors in detecting a particular symptom whose true status has an ordinal scale and is unknown—imperfect gold standard bias and ordinal scale symptom status. In this paper, we proposed a nonparametric maximum likelihood method for estimating and comparing the accuracy of different doctors in detecting a particular symptom without a gold standard when the true symptom status had an ordered multiple class. In addition, we extended the concept of the area under the receiver operating characteristic curve to a hyper-dimensional overall accuracy for diagnostic accuracy and alternative graphs for displaying a visual result. The simulation studies showed that the proposed method had good performance in terms of bias and mean squared error. Finally, we applied our method to our motivating example on assessing the diagnostic abilities of 5 TCM doctors in detecting symptoms related to Chills disease. PMID:21209155

  12. Localization accuracy of sphere fiducials in computed tomography images

    NASA Astrophysics Data System (ADS)

    Kobler, Jan-Philipp; Díaz Díaz, Jesus; Fitzpatrick, J. Michael; Lexow, G. Jakob; Majdani, Omid; Ortmaier, Tobias

    2014-03-01

    In recent years, bone-attached robots and microstereotactic frames have attracted increasing interest due to the promising targeting accuracy they provide. Such devices attach to a patient's skull via bone anchors, which are used as landmarks during intervention planning as well. However, as simulation results reveal, the performance of such mechanisms is limited by errors occurring during the localization of their bone anchors in preoperatively acquired computed tomography images. Therefore, it is desirable to identify the most suitable fiducials as well as the most accurate method for fiducial localization. We present experimental results of a study focusing on the fiducial localization error (FLE) of spheres. Two phantoms equipped with fiducials made from ferromagnetic steel and titanium, respectively, are used to compare two clinically available imaging modalities (multi-slice CT (MSCT) and cone-beam CT (CBCT)), three localization algorithms as well as two methods for approximating the FLE. Furthermore, the impact of cubic interpolation applied to the images is investigated. Results reveal that, generally, the achievable localization accuracy in CBCT image data is significantly higher compared to MSCT imaging. The lowest FLEs (approx. 40 μm) are obtained using spheres made from titanium, CBCT imaging, template matching based on cross correlation for localization, and interpolating the images by a factor of sixteen. Nevertheless, the achievable localization accuracy of spheres made from steel is only slightly inferior. The outcomes of the presented study will be valuable considering the optimization of future microstereotactic frame prototypes as well as the operative workflow.

  13. Good practices in free-energy calculations.

    PubMed

    Pohorille, Andrew; Jarzynski, Christopher; Chipot, Christophe

    2010-08-19

    As access to computational resources continues to increase, free-energy calculations have emerged as a powerful tool that can play a predictive role in a wide range of research areas. Yet, the reliability of these calculations can often be improved significantly if a number of precepts, or good practices, are followed. Although the theory upon which these good practices rely has largely been known for many years, it is often overlooked or simply ignored. In other cases, the theoretical developments are too recent for their potential to be fully grasped and merged into popular platforms for the computation of free-energy differences. In this contribution, the current best practices for carrying out free-energy calculations using free energy perturbation and nonequilibrium work methods are discussed, demonstrating that at little to no additional cost, free-energy estimates could be markedly improved and bounded by meaningful error estimates. Monitoring the probability distributions that underlie the transformation between the states of interest, performing the calculation bidirectionally, stratifying the reaction pathway, and choosing the most appropriate paradigms and algorithms for transforming between states offer significant gains in both accuracy and precision.

  14. Can Providing Rubrics for Writing Tasks Improve Developing Writers' Calibration Accuracy?

    ERIC Educational Resources Information Center

    Hawthorne, Katrice A.; Bol, Linda; Pribesh, Shana

    2017-01-01

    Rubric-referenced calibration and the interaction between writing achievement and calibration, a measure of the relationship between one's performance and the accuracy of one's judgments, were investigated. Undergraduate students (N = 596) were assigned to one of three calibration conditions: (a) global, (b) global and general criteria, or (c)…

  15. Diagnostic accuracy of language sample measures with Persian-speaking preschool children.

    PubMed

    Kazemi, Yalda; Klee, Thomas; Stringer, Helen

    2015-04-01

    This study examined the diagnostic accuracy of selected language sample measures (LSMs) with Persian-speaking children. A pre-accuracy study followed by phase I and II studies are reported. Twenty-four Persian-speaking children, aged 42 to 54 months, with primary language impairment (PLI) were compared to 27 age-matched children without PLI on a set of measures derived from play-based, conversational language samples. Results showed that correlations between age and LSMs were not statistically significant in either group of children. However, a majority of LSMs differentiated children with and without PLI at the group level (phase I), while three of the measures exhibited good diagnostic accuracy at the level of the individual (phase II). We conclude that general LSMs are promising for distinguishing between children with and without PLI. Persian-specific measures are mainly helpful in identifying children without language impairment while their ability to identify children with PLI is poor.

  16. Multi-wavelength approach towards on-product overlay accuracy and robustness

    NASA Astrophysics Data System (ADS)

    Bhattacharyya, Kaustuve; Noot, Marc; Chang, Hammer; Liao, Sax; Chang, Ken; Gosali, Benny; Su, Eason; Wang, Cathy; den Boef, Arie; Fouquet, Christophe; Huang, Guo-Tsai; Chen, Kai-Hsiung; Cheng, Kevin; Lin, John

    2018-03-01

    Success of diffraction-based overlay (DBO) technique1,4,5 in the industry is not just for its good precision and low toolinduced shift, but also for the measurement accuracy2 and robustness that DBO can provide. Significant efforts are put in to capitalize on the potential that DBO has to address measurement accuracy and robustness. Introduction of many measurement wavelength choices (continuous wavelength) in DBO is one of the key new capabilities in this area. Along with the continuous choice of wavelengths, the algorithms (fueled by swing-curve physics) on how to use these wavelengths are of high importance for a robust recipe setup that can avoid the impact from process stack variations (symmetric as well as asymmetric). All these are discussed. Moreover, another aspect of boosting measurement accuracy and robustness is discussed that deploys the capability to combine overlay measurement data from multiple wavelength measurements. The goal is to provide a method to make overlay measurements immune from process stack variations and also to report health KPIs for every measurement. By combining measurements from multiple wavelengths, a final overlay measurement is generated. The results show a significant benefit in accuracy and robustness against process stack variation. These results are supported by both measurement data as well as simulation from many product stacks.

  17. Accuracy Analysis of a Box-wing Theoretical SRP Model

    NASA Astrophysics Data System (ADS)

    Wang, Xiaoya; Hu, Xiaogong; Zhao, Qunhe; Guo, Rui

    2016-07-01

    For Beidou satellite navigation system (BDS) a high accuracy SRP model is necessary for high precise applications especially with Global BDS establishment in future. The BDS accuracy for broadcast ephemeris need be improved. So, a box-wing theoretical SRP model with fine structure and adding conical shadow factor of earth and moon were established. We verified this SRP model by the GPS Block IIF satellites. The calculation was done with the data of PRN 1, 24, 25, 27 satellites. The results show that the physical SRP model for POD and forecast for GPS IIF satellite has higher accuracy with respect to Bern empirical model. The 3D-RMS of orbit is about 20 centimeters. The POD accuracy for both models is similar but the prediction accuracy with the physical SRP model is more than doubled. We tested 1-day 3-day and 7-day orbit prediction. The longer is the prediction arc length, the more significant is the improvement. The orbit prediction accuracy with the physical SRP model for 1-day, 3-day and 7-day arc length are 0.4m, 2.0m, 10.0m respectively. But they are 0.9m, 5.5m and 30m with Bern empirical model respectively. We apply this means to the BDS and give out a SRP model for Beidou satellites. Then we test and verify the model with Beidou data of one month only for test. Initial results show the model is good but needs more data for verification and improvement. The orbit residual RMS is similar to that with our empirical force model which only estimate the force for along track, across track direction and y-bias. But the orbit overlap and SLR observation evaluation show some improvement. The remaining empirical force is reduced significantly for present Beidou constellation.

  18. Assessment of neuropsychiatric symptoms in dementia: toward improving accuracy

    PubMed Central

    Stella, Florindo

    2013-01-01

    The issue of this article concerned the discussion about tools frequently used tools for assessing neuropsychiatric symptoms of patients with dementia, particularly Alzheimer's disease. The aims were to discuss the main tools for evaluating behavioral disturbances, and particularly the accuracy of the Neuropsychiatric Inventory – Clinician Rating Scale (NPI-C). The clinical approach to and diagnosis of neuropsychiatric syndromes in dementia require suitable accuracy. Advances in the recognition and early accurate diagnosis of psychopathological symptoms help guide appropriate pharmacological and non-pharmacological interventions. In addition, recommended standardized and validated measurements contribute to both scientific research and clinical practice. Emotional distress, caregiver burden, and cognitive impairment often experienced by elderly caregivers, may affect the quality of caregiver reports. The clinician rating approach helps attenuate these misinterpretations. In this scenario, the NPI-C is a promising and versatile tool for assessing neuropsychiatric syndromes in dementia, offering good accuracy and high reliability, mainly based on the diagnostic impression of the clinician. This tool can provide both strategies: a comprehensive assessment of neuropsychiatric symptoms in dementia or the investigation of specific psychopathological syndromes such as agitation, depression, anxiety, apathy, sleep disorders, and aberrant motor disorders, among others. PMID:29213846

  19. Alternative Methods for Estimating Achievement Trends and School Effects: When Is Simple Good Enough?

    ERIC Educational Resources Information Center

    Warkentien, Siri; Silver, David

    2016-01-01

    Public schools with impressive records of serving lower-performing students are often overlooked because their average test scores, even when students are growing quickly, are lower than scores in schools that serve higher-performing students. Schools may appear to be doing poorly either because baseline achievement is not easily accounted for or…

  20. Application of Mensuration Technology to Improve the Accuracy of Field Artillery Firing Unit Location

    DTIC Science & Technology

    2013-12-13

    8 U.S. Army Field Artillery Operations ............................................................................ 8 Geodesy ...Experts in this field of study have a full working knowledge of geodesy and the theory that allows mensuration to surpass the level of accuracy achieved...desired. (2) Fire that is intended to achieve the desired result on target.”6 Geodesy : “that branch of applied mathematics which determines by observation

  1. Halo abundance matching: accuracy and conditions for numerical convergence

    NASA Astrophysics Data System (ADS)

    Klypin, Anatoly; Prada, Francisco; Yepes, Gustavo; Heß, Steffen; Gottlöber, Stefan

    2015-03-01

    Accurate predictions of the abundance and clustering of dark matter haloes play a key role in testing the standard cosmological model. Here, we investigate the accuracy of one of the leading methods of connecting the simulated dark matter haloes with observed galaxies- the halo abundance matching (HAM) technique. We show how to choose the optimal values of the mass and force resolution in large volume N-body simulations so that they provide accurate estimates for correlation functions and circular velocities for haloes and their subhaloes - crucial ingredients of the HAM method. At the 10 per cent accuracy, results converge for ˜50 particles for haloes and ˜150 particles for progenitors of subhaloes. In order to achieve this level of accuracy a number of conditions should be satisfied. The force resolution for the smallest resolved (sub)haloes should be in the range (0.1-0.3)rs, where rs is the scale radius of (sub)haloes. The number of particles for progenitors of subhaloes should be ˜150. We also demonstrate that the two-body scattering plays a minor role for the accuracy of N-body simulations thanks to the relatively small number of crossing-times of dark matter in haloes, and the limited force resolution of cosmological simulations.

  2. Increase in the Accuracy of Calculating Length of Horizontal Cable SCS in Civil Engineering

    NASA Astrophysics Data System (ADS)

    Semenov, A.

    2017-11-01

    A modification of the method for calculating the horizontal cable consumption of SCS established at civil engineering facilities is proposed. The proposed procedure preserves the prototype simplicity and provides a 5 percent accuracy increase. The values of the achieved accuracy are justified, their compliance with the practice of real projects is proved. The method is brought to the level of the engineering algorithm and formalized in the form of 12/70 rule.

  3. A systematic evaluation of prevalence and diagnostic accuracy of sacroiliac joint interventions.

    PubMed

    Simopoulos, Thomas T; Manchikanti, Laxmaiah; Singh, Vijay; Gupta, Sanjeeva; Hameed, Haroon; Diwan, Sudhir; Cohen, Steven P

    2012-01-01

    The contributions of the sacroiliac joint to low back and lower extremity pain have been a subject of considerable debate and research. It is generally accepted that 10% to 25% of patients with persistent mechanical low back pain below L5 have pain secondary to sacroiliac joint pathology. However, no single historical, physical exam, or radiological feature can definitively establish a diagnosis of sacroiliac joint pain. Based on present knowledge, a proper diagnosis can only be made using controlled diagnostic blocks. The diagnosis and treatment of sacroiliac joint pain continue to be characterized by wide variability and a paucity of the literature. To evaluate the accuracy of diagnostic sacroiliac joint interventions. A systematic review of diagnostic sacroiliac joint interventions. Methodological quality assessment of included studies was performed using Quality Appraisal of Reliability Studies (QAREL). Only diagnostic accuracy studies meeting at least 50% of the designated inclusion criteria were utilized for analysis. Studies scoring less than 50% are presented descriptively and analyzed critically. The level of evidence was classified as good, fair, or poor based on the quality of evidence developed by the United States Preventive Services Task Force (USPSTF). Data sources included relevant literature identified through searches of PubMed and EMBASE from 1966 to December 2011, and manual searches of the bibliographies of known primary and review articles. In this evaluation we utilized controlled local anesthetic blocks using at least 50% pain relief as the reference standard. The evidence is good for the diagnosis of sacroiliac joint pain utilizing controlled comparative local anesthetic blocks. The prevalence of sacroiliac joint pain is estimated to range between 10% and 62% based on the setting; however, the majority of analyzed studies suggest a point prevalence of around 25%, with a false-positive rate for uncontrolled blocks of approximately 20%. The

  4. A real-time freehand ultrasound calibration system with automatic accuracy feedback and control.

    PubMed

    Chen, Thomas Kuiran; Thurston, Adrian D; Ellis, Randy E; Abolmaesumi, Purang

    2009-01-01

    This article describes a fully automatic, real-time, freehand ultrasound calibration system. The system was designed to be simple and sterilizable, intended for operating-room usage. The calibration system employed an automatic-error-retrieval and accuracy-control mechanism based on a set of ground-truth data. Extensive validations were conducted on a data set of 10,000 images in 50 independent calibration trials to thoroughly investigate the accuracy, robustness, and performance of the calibration system. On average, the calibration accuracy (measured in three-dimensional reconstruction error against a known ground truth) of all 50 trials was 0.66 mm. In addition, the calibration errors converged to submillimeter in 98% of all trials within 12.5 s on average. Overall, the calibration system was able to consistently, efficiently and robustly achieve high calibration accuracy with real-time performance.

  5. On the Accuracy of Language Trees

    PubMed Central

    Pompei, Simone; Loreto, Vittorio; Tria, Francesca

    2011-01-01

    Historical linguistics aims at inferring the most likely language phylogenetic tree starting from information concerning the evolutionary relatedness of languages. The available information are typically lists of homologous (lexical, phonological, syntactic) features or characters for many different languages: a set of parallel corpora whose compilation represents a paramount achievement in linguistics. From this perspective the reconstruction of language trees is an example of inverse problems: starting from present, incomplete and often noisy, information, one aims at inferring the most likely past evolutionary history. A fundamental issue in inverse problems is the evaluation of the inference made. A standard way of dealing with this question is to generate data with artificial models in order to have full access to the evolutionary process one is going to infer. This procedure presents an intrinsic limitation: when dealing with real data sets, one typically does not know which model of evolution is the most suitable for them. A possible way out is to compare algorithmic inference with expert classifications. This is the point of view we take here by conducting a thorough survey of the accuracy of reconstruction methods as compared with the Ethnologue expert classifications. We focus in particular on state-of-the-art distance-based methods for phylogeny reconstruction using worldwide linguistic databases. In order to assess the accuracy of the inferred trees we introduce and characterize two generalizations of standard definitions of distances between trees. Based on these scores we quantify the relative performances of the distance-based algorithms considered. Further we quantify how the completeness and the coverage of the available databases affect the accuracy of the reconstruction. Finally we draw some conclusions about where the accuracy of the reconstructions in historical linguistics stands and about the leading directions to improve it. PMID:21674034

  6. Influence of non-level walking on pedometer accuracy.

    PubMed

    Leicht, Anthony S; Crowther, Robert G

    2009-05-01

    The YAMAX Digiwalker pedometer has been previously confirmed as a valid and reliable monitor during level walking, however, little is known about its accuracy during non-level walking activities or between genders. Subsequently, this study examined the influence of non-level walking and gender on pedometer accuracy. Forty-six healthy adults completed 3-min bouts of treadmill walking at their normal walking pace during 11 inclines (0-10%) while another 123 healthy adults completed walking up and down 47 stairs. During walking, participants wore a YAMAX Digiwalker SW-700 pedometer with the number of steps taken and registered by the pedometer recorded. Pedometer difference (steps registered-steps taken), net error (% of steps taken), absolute error (absolute % of steps taken) and gender were examined by repeated measures two-way ANOVA and Tukey's post hoc tests. During incline walking, pedometer accuracy indices were similar between inclines and gender except for a significantly greater step difference (-7+/-5 steps vs. 1+/-4 steps) and net error (-2.4+/-1.8% for 9% vs. 0.4+/-1.2% for 2%). Step difference and net error were significantly greater during stair descent compared to stair ascent while absolute error was significantly greater during stair ascent compared to stair descent. The current study demonstrated that the YAMAX Digiwalker SW-700 pedometer exhibited good accuracy during incline walking up to 10% while it overestimated steps taken during stair ascent/descent with greater overestimation during stair descent. Stair walking activity should be documented in field studies as the YAMAX Digiwalker SW-700 pedometer overestimates this activity type.

  7. Positioning accuracy in a registration-free CT-based navigation system

    NASA Astrophysics Data System (ADS)

    Brandenberger, D.; Birkfellner, W.; Baumann, B.; Messmer, P.; Huegli, R. W.; Regazzoni, P.; Jacob, A. L.

    2007-12-01

    In order to maintain overall navigation accuracy established by a calibration procedure in our CT-based registration-free navigation system, the CT scanner has to repeatedly generate identical volume images of a target at the same coordinates. We tested the positioning accuracy of the prototype of an advanced workplace for image-guided surgery (AWIGS) which features an operating table capable of direct patient transfer into a CT scanner. Volume images (N = 154) of a specialized phantom were analysed for translational shifting after various table translations. Variables included added weight and phantom position on the table. The navigation system's calibration accuracy was determined (bias 2.1 mm, precision ± 0.7 mm, N = 12). In repeated use, a bias of 3.0 mm and a precision of ± 0.9 mm (N = 10) were maintainable. Instances of translational image shifting were related to the table-to-CT scanner docking mechanism. A distance scaling error when altering the table's height was detected. Initial prototype problems visible in our study causing systematic errors were resolved by repeated system calibrations between interventions. We conclude that the accuracy achieved is sufficient for a wide range of clinical applications in surgery and interventional radiology.

  8. Effects of using the developing nurses' thinking model on nursing students' diagnostic accuracy.

    PubMed

    Tesoro, Mary Gay

    2012-08-01

    This quasi-experimental study tested the effectiveness of an educational model, Developing Nurses' Thinking (DNT), on nursing students' clinical reasoning to achieve patient safety. Teaching nursing students to develop effective thinking habits that promote positive patient outcomes and patient safety is a challenging endeavor. Positive patient outcomes and safety are achieved when nurses accurately interpret data and subsequently implement appropriate plans of care. This study's pretest-posttest design determined whether use of the DNT model during 2 weeks of clinical postconferences improved nursing students' (N = 83) diagnostic accuracy. The DNT model helps students to integrate four constructs-patient safety, domain knowledge, critical thinking processes, and repeated practice-to guide their thinking when interpreting patient data and developing effective plans of care. The posttest scores of students from the intervention group showed statistically significant improvement in accuracy. Copyright 2012, SLACK Incorporated.

  9. Using Language Sample Analysis in Clinical Practice: Measures of Grammatical Accuracy for Identifying Language Impairment in Preschool and School-Aged Children.

    PubMed

    Eisenberg, Sarita; Guo, Ling-Yu

    2016-05-01

    This article reviews the existing literature on the diagnostic accuracy of two grammatical accuracy measures for differentiating children with and without language impairment (LI) at preschool and early school age based on language samples. The first measure, the finite verb morphology composite (FVMC), is a narrow grammatical measure that computes children's overall accuracy of four verb tense morphemes. The second measure, percent grammatical utterances (PGU), is a broader grammatical measure that computes children's accuracy in producing grammatical utterances. The extant studies show that FVMC demonstrates acceptable (i.e., 80 to 89% accurate) to good (i.e., 90% accurate or higher) diagnostic accuracy for children between 4;0 (years;months) and 6;11 in conversational or narrative samples. In contrast, PGU yields acceptable to good diagnostic accuracy for children between 3;0 and 8;11 regardless of sample types. Given the diagnostic accuracy shown in the literature, we suggest that FVMC and PGU can be used as one piece of evidence for identifying children with LI in assessment when appropriate. However, FVMC or PGU should not be used as therapy goals directly. Instead, when children are low in FVMC or PGU, we suggest that follow-up analyses should be conducted to determine the verb tense morphemes or grammatical structures that children have difficulty with. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  10. Teaching High-Accuracy Global Positioning System to Undergraduates Using Online Processing Services

    ERIC Educational Resources Information Center

    Wang, Guoquan

    2013-01-01

    High-accuracy Global Positioning System (GPS) has become an important geoscientific tool used to measure ground motions associated with plate movements, glacial movements, volcanoes, active faults, landslides, subsidence, slow earthquake events, as well as large earthquakes. Complex calculations are required in order to achieve high-precision…

  11. Accuracy analysis and design of A3 parallel spindle head

    NASA Astrophysics Data System (ADS)

    Ni, Yanbing; Zhang, Biao; Sun, Yupeng; Zhang, Yuan

    2016-03-01

    As functional components of machine tools, parallel mechanisms are widely used in high efficiency machining of aviation components, and accuracy is one of the critical technical indexes. Lots of researchers have focused on the accuracy problem of parallel mechanisms, but in terms of controlling the errors and improving the accuracy in the stage of design and manufacturing, further efforts are required. Aiming at the accuracy design of a 3-DOF parallel spindle head(A3 head), its error model, sensitivity analysis and tolerance allocation are investigated. Based on the inverse kinematic analysis, the error model of A3 head is established by using the first-order perturbation theory and vector chain method. According to the mapping property of motion and constraint Jacobian matrix, the compensatable and uncompensatable error sources which affect the accuracy in the end-effector are separated. Furthermore, sensitivity analysis is performed on the uncompensatable error sources. The sensitivity probabilistic model is established and the global sensitivity index is proposed to analyze the influence of the uncompensatable error sources on the accuracy in the end-effector of the mechanism. The results show that orientation error sources have bigger effect on the accuracy in the end-effector. Based upon the sensitivity analysis results, the tolerance design is converted into the issue of nonlinearly constrained optimization with the manufacturing cost minimum being the optimization objective. By utilizing the genetic algorithm, the allocation of the tolerances on each component is finally determined. According to the tolerance allocation results, the tolerance ranges of ten kinds of geometric error sources are obtained. These research achievements can provide fundamental guidelines for component manufacturing and assembly of this kind of parallel mechanisms.

  12. Accuracy evaluation of 3D lidar data from small UAV

    NASA Astrophysics Data System (ADS)

    Tulldahl, H. M.; Bissmarck, Fredrik; Larsson, Hâkan; Grönwall, Christina; Tolt, Gustav

    2015-10-01

    A UAV (Unmanned Aerial Vehicle) with an integrated lidar can be an efficient system for collection of high-resolution and accurate three-dimensional (3D) data. In this paper we evaluate the accuracy of a system consisting of a lidar sensor on a small UAV. High geometric accuracy in the produced point cloud is a fundamental qualification for detection and recognition of objects in a single-flight dataset as well as for change detection using two or several data collections over the same scene. Our work presented here has two purposes: first to relate the point cloud accuracy to data processing parameters and second, to examine the influence on accuracy from the UAV platform parameters. In our work, the accuracy is numerically quantified as local surface smoothness on planar surfaces, and as distance and relative height accuracy using data from a terrestrial laser scanner as reference. The UAV lidar system used is the Velodyne HDL-32E lidar on a multirotor UAV with a total weight of 7 kg. For processing of data into a geographically referenced point cloud, positioning and orientation of the lidar sensor is based on inertial navigation system (INS) data combined with lidar data. The combination of INS and lidar data is achieved in a dynamic calibration process that minimizes the navigation errors in six degrees of freedom, namely the errors of the absolute position (x, y, z) and the orientation (pitch, roll, yaw) measured by GPS/INS. Our results show that low-cost and light-weight MEMS based (microelectromechanical systems) INS equipment with a dynamic calibration process can obtain significantly improved accuracy compared to processing based solely on INS data.

  13. An angle encoder for super-high resolution and super-high accuracy using SelfA

    NASA Astrophysics Data System (ADS)

    Watanabe, Tsukasa; Kon, Masahito; Nabeshima, Nobuo; Taniguchi, Kayoko

    2014-06-01

    Angular measurement technology at high resolution for applications such as in hard disk drive manufacturing machines, precision measurement equipment and aspherical process machines requires a rotary encoder with high accuracy, high resolution and high response speed. However, a rotary encoder has angular deviation factors during operation due to scale error or installation error. It has been assumed to be impossible to achieve accuracy below 0.1″ in angular measurement or control after the installation onto the rotating axis. Self-calibration (Lu and Trumper 2007 CIRP Ann. 56 499; Kim et al 2011 Proc. MacroScale; Probst 2008 Meas. Sci. Technol. 19 015101; Probst et al Meas. Sci. Technol. 9 1059; Tadashi and Makoto 1993 J. Robot. Mechatronics 5 448; Ralf et al 2006 Meas. Sci. Technol. 17 2811) and cross-calibration (Probst et al 1998 Meas. Sci. Technol. 9 1059; Just et al 2009 Precis. Eng. 33 530; Burnashev 2013 Quantum Electron. 43 130) technologies for a rotary encoder have been actively discussed on the basis of the principle of circular closure. This discussion prompted the development of rotary tables which achieve reliable and high accuracy angular verification. We apply these technologies for the development of a rotary encoder not only to meet the requirement of super-high accuracy but also to meet that of super-high resolution. This paper presents the development of an encoder with 221 = 2097 152 resolutions per rotation (360°), that is, corresponding to a 0.62″ signal period, achieved by the combination of a laser rotary encoder supplied by Magnescale Co., Ltd and a self-calibratable encoder (SelfA) supplied by The National Institute of Advanced Industrial Science & Technology (AIST). In addition, this paper introduces the development of a rotary encoder to guarantee ±0.03″ accuracy at any point of the interpolated signal, with respect to the encoder at the minimum resolution of 233, that is, corresponding to a 0.0015″ signal period after

  14. Accuracy of intraoral data acquisition in comparison to the conventional impression.

    PubMed

    Luthardt, R G; Loos, R; Quaas, S

    2005-10-01

    The achievable accuracy is a decisive parameter for the comparison of direct intraoral digitization with the conventional impression. The objective of the study was therefore to compare the accuracy of the reproduction of a model situation by intraoral digitization vs. the conventional procedure consisting of impression taking, model production, and extraoral digitization. Proceeding from a die model with a prepared tooth 16, the reference data set of the teeth 15, 16 and 17 was produced with an established procedure by means ofextraoral digitization. For the simulated intraoral data acquisition of the master model (Cerec 3D camera, Sirona, Bensheim), the camera was fastened on a stand for the measurement and the teeth digitized seven times each in defined views (occlusal, and in each case inclined by 20 degrees, from the mesio-proximal, disto-proximal, vestibular and oral aspect). Matching was automated (comparative data sets B1-B5). A clinically perfect one-step putty-and-wash impression was taken from the starting model. The model produced under defined conditions was digitized extraorally five times (digi-SCAN, comparative data sets C1-C5). The data sets B1-B5 and C1-C5 were assigned to the reference data set by means of best-fit matching and the root of the mean quadratic deviation (RMS; root mean square) calculated. The deviations were visualized, and mean positive, negative and absolute deviations calculated. The mean RMS was 27.9 microm (B1-B5) or 18.8 microm (C1-C5). The mean deviations for the prepared tooth were 18 microm/-17 microm (B1-B5) and 9 microm /-9 microm (C1-C5). For tooth 15, the mean deviations were 22 microm/-19 microm (B1-B5) and 15 microm/-16 microm (C1-C5). The intraoral method showed good results with deviations from the CAD starting model of approx. 17 microm, related to the prepared tooth 16. On the whole, in this in-vitro study, extraoral digitization with impression taking and model production showed higher accuracy than intraoral

  15. Microwave bio-sensor based on symmetrical split ring resonator with spurline filters for therapeutic goods detection.

    PubMed

    Alahnomi, Rammah A; Zakaria, Z; Ruslan, E; Ab Rashid, S R; Mohd Bahar, Amyrul Azuan; Shaaban, Azizah

    2017-01-01

    A novel symmetrical split ring resonator (SSRR) based microwave sensor with spurline filters for detecting and characterizing the properties of solid materials has been developed. Due to the weak perturbation in the interaction of material under test (MUT) and planar microwave sensor, spurline filters were embedded to the SSRR microwave sensor which effectively enhanced Q-factor with suppressing the undesired harmonic frequency. The spurline filter structures force the presented sensor to resonate at a fundamental frequency of 2.2 GHz with the capabilities of suppressing rejected harmonic frequency and miniaturization in circuit size. A wide bandwidth rejection is achieved by using double spurlines filters with high Q-factor achievement (up to 652.94) compared to single spurline filter. The new SSRR sensor with spurline filters displayed desired properties such as high sensitivity, accuracy, and performance with a 1.3% typical percentage error in the measurement results. Furthermore, the sensor has been successfully applied for detecting and characterizing solid materials (such as Roger 5880, Roger 4350, and FR4) and evidently demonstrated that it can suppress the harmonic frequency effectively. This novel design with harmonic suppression is useful for various applications such as food industry (meat, fruit, vegetables), biological medicine (derived from proteins and other substances produced by the body), and Therapeutic goods (antiseptics, vitamins, anti-psychotics, and other medicines).

  16. Microwave bio-sensor based on symmetrical split ring resonator with spurline filters for therapeutic goods detection

    PubMed Central

    Ruslan, E.; Ab Rashid, S. R.; Mohd Bahar, Amyrul Azuan; Shaaban, Azizah

    2017-01-01

    A novel symmetrical split ring resonator (SSRR) based microwave sensor with spurline filters for detecting and characterizing the properties of solid materials has been developed. Due to the weak perturbation in the interaction of material under test (MUT) and planar microwave sensor, spurline filters were embedded to the SSRR microwave sensor which effectively enhanced Q-factor with suppressing the undesired harmonic frequency. The spurline filter structures force the presented sensor to resonate at a fundamental frequency of 2.2 GHz with the capabilities of suppressing rejected harmonic frequency and miniaturization in circuit size. A wide bandwidth rejection is achieved by using double spurlines filters with high Q-factor achievement (up to 652.94) compared to single spurline filter. The new SSRR sensor with spurline filters displayed desired properties such as high sensitivity, accuracy, and performance with a 1.3% typical percentage error in the measurement results. Furthermore, the sensor has been successfully applied for detecting and characterizing solid materials (such as Roger 5880, Roger 4350, and FR4) and evidently demonstrated that it can suppress the harmonic frequency effectively. This novel design with harmonic suppression is useful for various applications such as food industry (meat, fruit, vegetables), biological medicine (derived from proteins and other substances produced by the body), and Therapeutic goods (antiseptics, vitamins, anti-psychotics, and other medicines). PMID:28934301

  17. Modern psychometrics for assessing achievement goal orientation: a Rasch analysis.

    PubMed

    Muis, Krista R; Winne, Philip H; Edwards, Ordene V

    2009-09-01

    A program of research is needed that assesses the psychometric properties of instruments designed to quantify students' achievement goal orientations to clarify inconsistencies across previous studies and to provide a stronger basis for future research. We conducted traditional psychometric and modern Rasch-model analyses of the Achievement Goals Questionnaire (AGQ, Elliot & McGregor, 2001) and the Patterns of Adaptive Learning Scale (PALS, Midgley et al., 2000) to provide an in-depth analysis of the two most popular instruments in educational psychology. For Study 1, 217 undergraduate students enrolled in educational psychology courses participated. Thirty-four were male and 181 were female (two did not respond). Participants completed the AGQ in the context of their educational psychology class. For Study 2, 126 undergraduate students enrolled in educational psychology courses participated. Thirty were male and 95 were female (one did not respond). Participants completed the PALS in the context of their educational psychology class. Traditional psychometric assessments of the AGQ and PALS replicated previous studies. For both, reliability estimates ranged from good to very good for raw subscale scores and fit for the models of goal orientations were good. Based on traditional psychometrics, the AGQ and PALS are valid and reliable indicators of achievement goals. Rasch analyses revealed that estimates of reliability for items were very good but respondent ability estimates varied from poor to good for both the AGQ and PALS. These findings indicate that items validly and reliably reflect a group's aggregate goal orientation, but using either instrument to characterize an individual's goal orientation is hazardous.

  18. Accuracy of Different Modalities to Record Natural Head Position in 3 Dimensions: A Systematic Review.

    PubMed

    Leung, Ming Yin; Lo, John; Leung, Yiu Yan

    2016-11-01

    Three-dimensional (3D) images are taken with positioning devices to ensure a patient's stability, which, however, place the patient's head into a random orientation. Reorientation of images to the natural head position (NHP) is necessary for appropriate assessment of dentofacial deformities before any surgical planning. The aim of this study was to review the literature systematically to identify and evaluate the various modalities available to record the NHP in 3 dimensions and to compare their accuracy. A systematic literature search of the PubMed, Cochrane Library and Embase databases, with no limitations on publication time or language, was performed in July 2015. The search and evaluations of articles were performed in 4 rounds. The methodologies, accuracies, advantages, and limitations of various modalities to record NHP were examined. Eight articles were included in the final review. Six modalities to record NHP were identified, namely 1) stereophotogrammetry, 2) facial markings along laser lines, 3) clinical photographs and the pose from orthography and scaling with iterations (POSIT) algorithm, 4) digital orientation sensing, 5) handheld 3D camera measuring system, and 6) laser scanning. Digital orientation sensing had good accuracy, with mean angular differences from the reference within 1° (0.07 ± 0.49° and 0.12 ± 0.54°, respectively). Laser scanning was shown to be comparable to digital orientation sensing. The method involving clinical photographs and the POSIT algorithm was reported to have good accuracy, with mean angular differences for pitch, roll, and yaw within 1° (-0.17 ± 0.50°). Stereophotogrammetry was reported to have the highest reliability, with mean angular deviations in pitch, roll, and yaw for active and passive stereophotogrammetric devices within 0.1° (0.004771 ± 0.045645° and 0.007572 ± 0.079088°, respectively). This systematic review showed that recording the NHP in 3 dimensions with a digital orientation sensor has good

  19. Selecting good regions to deblur via relative total variation

    NASA Astrophysics Data System (ADS)

    Li, Lerenhan; Yan, Hao; Fan, Zhihua; Zheng, Hanqing; Gao, Changxin; Sang, Nong

    2018-03-01

    Image deblurring is to estimate the blur kernel and to restore the latent image. It is usually divided into two stage, including kernel estimation and image restoration. In kernel estimation, selecting a good region that contains structure information is helpful to the accuracy of estimated kernel. Good region to deblur is usually expert-chosen or in a trial-anderror way. In this paper, we apply a metric named relative total variation (RTV) to discriminate the structure regions from smooth and texture. Given a blurry image, we first calculate the RTV of each pixel to determine whether it is the pixel in structure region, after which, we sample the image in an overlapping way. At last, the sampled region that contains the most structure pixels is the best region to deblur. Both qualitative and quantitative experiments show that our proposed method can help to estimate the kernel accurately.

  20. Decision Accuracy and the Role of Spatial Interaction in Opinion Dynamics

    NASA Astrophysics Data System (ADS)

    Torney, Colin J.; Levin, Simon A.; Couzin, Iain D.

    2013-04-01

    The opinions and actions of individuals within interacting groups are frequently determined by both social and personal information. When sociality (or the pressure to conform) is strong and individual preferences are weak, groups will remain cohesive until a consensus decision is reached. When group decisions are subject to a bias, representing for example private information known by some members of the population or imperfect information known by all, then the accuracy achieved for a fixed level of bias will increase with population size. In this work we determine how the scaling between accuracy and group size can be related to the microscopic properties of the decision-making process. By simulating a spatial model of opinion dynamics we show that the relationship between the instantaneous fraction of leaders in the population ( L), system size ( N), and accuracy depends on the frequency of individual opinion switches and the level of population viscosity. When social mixing is slow, and individual opinion changes are frequent, accuracy is determined by the absolute number of informed individuals. As mixing rates increase, or the rate of opinion updates decrease, a transition occurs to a regime where accuracy is determined by the value of L√{ N}. We investigate the transition between different scaling regimes analytically by examining a well-mixed limit.

  1. A design of optical modulation system with pixel-level modulation accuracy

    NASA Astrophysics Data System (ADS)

    Zheng, Shiwei; Qu, Xinghua; Feng, Wei; Liang, Baoqiu

    2018-01-01

    Vision measurement has been widely used in the field of dimensional measurement and surface metrology. However, traditional methods of vision measurement have many limits such as low dynamic range and poor reconfigurability. The optical modulation system before image formation has the advantage of high dynamic range, high accuracy and more flexibility, and the modulation accuracy is the key parameter which determines the accuracy and effectiveness of optical modulation system. In this paper, an optical modulation system with pixel level accuracy is designed and built based on multi-points reflective imaging theory and digital micromirror device (DMD). The system consisted of digital micromirror device, CCD camera and lens. Firstly we achieved accurate pixel-to-pixel correspondence between the DMD mirrors and the CCD pixels by moire fringe and an image processing of sampling and interpolation. Then we built three coordinate systems and calculated the mathematic relationship between the coordinate of digital micro-mirror and CCD pixels using a checkerboard pattern. A verification experiment proves that the correspondence error is less than 0.5 pixel. The results show that the modulation accuracy of system meets the requirements of modulation. Furthermore, the high reflecting edge of a metal circular piece can be detected using the system, which proves the effectiveness of the optical modulation system.

  2. Accuracy analysis of the space shuttle solid rocket motor profile measuring device

    NASA Technical Reports Server (NTRS)

    Estler, W. Tyler

    1989-01-01

    The Profile Measuring Device (PMD) was developed at the George C. Marshall Space Flight Center following the loss of the Space Shuttle Challenger. It is a rotating gauge used to measure the absolute diameters of mating features of redesigned Solid Rocket Motor field joints. Diameter tolerance of these features are typically + or - 0.005 inches and it is required that the PMD absolute measurement uncertainty be within this tolerance. In this analysis, the absolute accuracy of these measurements were found to be + or - 0.00375 inches, worst case, with a potential accuracy of + or - 0.0021 inches achievable by improved temperature control.

  3. Secondary Students' Writing Achievement Goals: Assessing the Mediating Effects of Mastery and Performance Goals on Writing Self-Efficacy, Affect, and Writing Achievement

    PubMed Central

    Yilmaz Soylu, Meryem; Zeleny, Mary G.; Zhao, Ruomeng; Bruning, Roger H.; Dempsey, Michael S.; Kauffman, Douglas F.

    2017-01-01

    The two studies reported here explored the factor structure of the newly constructed Writing Achievement Goal Scale (WAGS), and examined relationships among secondary students' writing achievement goals, writing self-efficacy, affect for writing, and writing achievement. In the first study, 697 middle school students completed the WAGS. A confirmatory factor analysis revealed a good fit for this data with a three-factor model that corresponds with mastery, performance approach, and performance avoidance goals. The results of Study 1 were an indication for the researchers to move forward with Study 2, which included 563 high school students. The secondary students completed the WAGS, as well as the Self-efficacy for Writing Scale, and the Liking Writing Scale. Students also self-reported grades for writing and for language arts courses. Approximately 6 weeks later, students completed a statewide writing assessment. We tested a theoretical model representing relationships among Study 2 variables using structural equation modeling including students' responses to the study scales and students' scores on the statewide assessment. Results from Study 2 revealed a good fit between a model depicting proposed relationships among the constructs and the data. Findings are discussed relative to achievement goal theory and writing. PMID:28878707

  4. Fusion with Language Models Improves Spelling Accuracy for ERP-based Brain Computer Interface Spellers

    PubMed Central

    Orhan, Umut; Erdogmus, Deniz; Roark, Brian; Purwar, Shalini; Hild, Kenneth E.; Oken, Barry; Nezamfar, Hooman; Fried-Oken, Melanie

    2013-01-01

    Event related potentials (ERP) corresponding to a stimulus in electroencephalography (EEG) can be used to detect the intent of a person for brain computer interfaces (BCI). This paradigm is widely utilized to build letter-by-letter text input systems using BCI. Nevertheless using a BCI-typewriter depending only on EEG responses will not be sufficiently accurate for single-trial operation in general, and existing systems utilize many-trial schemes to achieve accuracy at the cost of speed. Hence incorporation of a language model based prior or additional evidence is vital to improve accuracy and speed. In this paper, we study the effects of Bayesian fusion of an n-gram language model with a regularized discriminant analysis ERP detector for EEG-based BCIs. The letter classification accuracies are rigorously evaluated for varying language model orders as well as number of ERP-inducing trials. The results demonstrate that the language models contribute significantly to letter classification accuracy. Specifically, we find that a BCI-speller supported by a 4-gram language model may achieve the same performance using 3-trial ERP classification for the initial letters of the words and using single trial ERP classification for the subsequent ones. Overall, fusion of evidence from EEG and language models yields a significant opportunity to increase the word rate of a BCI based typing system. PMID:22255652

  5. Configuration optimization and experimental accuracy evaluation of a bone-attached, parallel robot for skull surgery.

    PubMed

    Kobler, Jan-Philipp; Nuelle, Kathrin; Lexow, G Jakob; Rau, Thomas S; Majdani, Omid; Kahrs, Lueder A; Kotlarski, Jens; Ortmaier, Tobias

    2016-03-01

    Minimally invasive cochlear implantation is a novel surgical technique which requires highly accurate guidance of a drilling tool along a trajectory from the mastoid surface toward the basal turn of the cochlea. The authors propose a passive, reconfigurable, parallel robot which can be directly attached to bone anchors implanted in a patient's skull, avoiding the need for surgical tracking systems. Prior to clinical trials, methods are necessary to patient specifically optimize the configuration of the mechanism with respect to accuracy and stability. Furthermore, the achievable accuracy has to be determined experimentally. A comprehensive error model of the proposed mechanism is established, taking into account all relevant error sources identified in previous studies. Two optimization criteria to exploit the given task redundancy and reconfigurability of the passive robot are derived from the model. The achievable accuracy of the optimized robot configurations is first estimated with the help of a Monte Carlo simulation approach and finally evaluated in drilling experiments using synthetic temporal bone specimen. Experimental results demonstrate that the bone-attached mechanism exhibits a mean targeting accuracy of [Formula: see text] mm under realistic conditions. A systematic targeting error is observed, which indicates that accurate identification of the passive robot's kinematic parameters could further reduce deviations from planned drill trajectories. The accuracy of the proposed mechanism demonstrates its suitability for minimally invasive cochlear implantation. Future work will focus on further evaluation experiments on temporal bone specimen.

  6. A new accuracy measure based on bounded relative error for time series forecasting

    PubMed Central

    Twycross, Jamie; Garibaldi, Jonathan M.

    2017-01-01

    Many accuracy measures have been proposed in the past for time series forecasting comparisons. However, many of these measures suffer from one or more issues such as poor resistance to outliers and scale dependence. In this paper, while summarising commonly used accuracy measures, a special review is made on the symmetric mean absolute percentage error. Moreover, a new accuracy measure called the Unscaled Mean Bounded Relative Absolute Error (UMBRAE), which combines the best features of various alternative measures, is proposed to address the common issues of existing measures. A comparative evaluation on the proposed and related measures has been made with both synthetic and real-world data. The results indicate that the proposed measure, with user selectable benchmark, performs as well as or better than other measures on selected criteria. Though it has been commonly accepted that there is no single best accuracy measure, we suggest that UMBRAE could be a good choice to evaluate forecasting methods, especially for cases where measures based on geometric mean of relative errors, such as the geometric mean relative absolute error, are preferred. PMID:28339480

  7. A new accuracy measure based on bounded relative error for time series forecasting.

    PubMed

    Chen, Chao; Twycross, Jamie; Garibaldi, Jonathan M

    2017-01-01

    Many accuracy measures have been proposed in the past for time series forecasting comparisons. However, many of these measures suffer from one or more issues such as poor resistance to outliers and scale dependence. In this paper, while summarising commonly used accuracy measures, a special review is made on the symmetric mean absolute percentage error. Moreover, a new accuracy measure called the Unscaled Mean Bounded Relative Absolute Error (UMBRAE), which combines the best features of various alternative measures, is proposed to address the common issues of existing measures. A comparative evaluation on the proposed and related measures has been made with both synthetic and real-world data. The results indicate that the proposed measure, with user selectable benchmark, performs as well as or better than other measures on selected criteria. Though it has been commonly accepted that there is no single best accuracy measure, we suggest that UMBRAE could be a good choice to evaluate forecasting methods, especially for cases where measures based on geometric mean of relative errors, such as the geometric mean relative absolute error, are preferred.

  8. The Good Behavior Game with Students in Alternative Educational Environments: Interactions between Reinforcement Criteria and Scoring Accuracy

    ERIC Educational Resources Information Center

    Sy, Jolene R.; Gratz, Olivia; Donaldson, Jeanne M.

    2016-01-01

    The good behavior game (GBG) is a class-wide contingency management strategy that involves rewarding teams who engage in low levels of disruptive behavior. The GBG has been found to be effective with neuro-typical individuals from preschool to high school. In Study 1, teachers and experimenters implemented the GBG on alternating days in an…

  9. Is Alcohol Consumption Associated with Poor Academic Achievement in University Students?

    PubMed Central

    El Ansari, Walid; Stock, Christiane; Mills, Claire

    2013-01-01

    Background: We assessed associations between educational achievement and alcohol consumption. Methods: We employed five alcohol consumption measures (length of time of and amount consumed during most recent drinking occasion, frequency of alcohol consumption, heavy episodic drinking, problem drinking); and three educational achievement indicators (students’ subjective importance of achieving good grades, students’ appraisal of their academic performance in comparison with peers, students’ actual module mark). Results: Males were positively associated with all five alcohol consumption measures. Age was negatively associated with three alcohol consumption measures. While students´ importance of good grades was negatively associated with three alcohol consumption measures, academic performance in comparison with peers was negatively associated with heavy episodic drinking. Actual module mark was not associated with any alcohol consumption measure. Conclusions: Alcohol consumption showed negative associations with motivation for and subjectively achieved academic performance. University alcohol prevention activities might have positive impact on students’ academic success. PMID:24319558

  10. High-accuracy Aspheric X-ray Mirror Metrology Using Software Configurable Optical Test System/deflectometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Run; Su, Peng; Burge, James H.

    The Software Configurable Optical Test System (SCOTS) uses deflectometry to measure surface slopes of general optical shapes without the need for additional null optics. Careful alignment of test geometry and calibration of inherent system error improve the accuracy of SCOTS to a level where it competes with interferometry. We report a SCOTS surface measurement of an off-axis superpolished elliptical x-ray mirror that achieves <1 nm<1 nm root-mean-square accuracy for the surface measurement with low-order term included.

  11. [What everybody should know about good clinical practices].

    PubMed

    Osorio, Lyda

    2015-01-01

    An increasing number of countries are adopting good clinical practices guidelines as part of the regulation of clinical studies to register pharmaceutical products and other health-related products. Consequently, all parties involved in the research and development of these products should know them, implement them and ensure their compliance. However, good clinical practices guidelines are just one of the initiatives seeking to achieve the highest ethical and scientific standards in health research and in other areas where humans are research subjects. This review defines such practices and their objectives presenting in a practical manner their legal framework in Colombia, and clarifying their application in studies where interventions use no medications or those that are not clinical trials. Finally, the work discusses the challenges to ensure that good clinical practices contribute to the protection of research participants, the education of trustworthy health professionals, and a culture of respect for human beings.

  12. Volunteering leads to rock-paper-scissors dynamics in a public goods game

    NASA Astrophysics Data System (ADS)

    Semmann, Dirk; Krambeck, Hans-Jürgen; Milinski, Manfred

    2003-09-01

    Collective efforts are a trademark of both insect and human societies. They are achieved through relatedness in the former and unknown mechanisms in the latter. The problem of achieving cooperation among non-kin has been described as the `tragedy of the commons', prophesying the inescapable collapse of many human enterprises. In public goods experiments, initial cooperation usually drops quickly to almost zero. It can be maintained by the opportunity to punish defectors or the need to maintain good reputation. Both schemes require that defectors are identified. Theorists propose that a simple but effective mechanism operates under full anonymity. With optional participation in the public goods game, `loners' (players who do not join the group), defectors and cooperators will coexist through rock-paper-scissors dynamics. Here we show experimentally that volunteering generates these dynamics in public goods games and that manipulating initial conditions can produce each predicted direction. If, by manipulating displayed decisions, it is pretended that defectors have the highest frequency, loners soon become most frequent, as do cooperators after loners and defectors after cooperators. On average, cooperation is perpetuated at a substantial level.

  13. Food Science for the Public Good

    NASA Astrophysics Data System (ADS)

    Miller, Cassandra

    If you are interested in food science, looking for a meaningful career path, and are motivated by the desire to make a difference, you may find that a career working for the public good can be very rewarding. Often, such opportunities address issues of social responsibility, sustainability, public health, and/or economic development. Food scientists who choose this path typically have an interest in social and public health issues, and are usually driven by the achievement of some sort of social, health, or societal gain. As food science in itself is a very broad discipline, applying this knowledge for the public good can also take a variety of paths. Whether you're interested in manufacturing, food safety, nutrition, food policy, product development, quality control, marketing and sales, or any other discipline that makes up the diverse field of food science, various opportunities exist to make a difference to society.

  14. Effect of X-Word Grammar and Traditional Grammar Instruction on Grammatical Accuracy

    ERIC Educational Resources Information Center

    Livingston, Sue; Toce, Andi; Casey, Toce; Montoya, Fernando; Hart, Bonny R.; O'Flaherty, Carmela

    2018-01-01

    This study first briefly describes an instructional approach to teaching grammar known as X-Word Grammar and then compares its effectiveness in assisting students in achieving grammatical accuracy with traditionally taught grammar. Two groups of L2 pre-college students were taught using curricula and practice procedures in two different grammar…

  15. Speed, Dissipation, and Accuracy in Early T-cell Recognition

    NASA Astrophysics Data System (ADS)

    Cui, Wenping; Mehta, Pankaj

    In the immune system, T cells can perform self-foreign discrimination with great foreign ligand sensitivity, high decision speed and low energy cost. There is significant evidence T-cells achieve such great performance with a mechanism: kinetic proofreading(KPR). KPR-based mechanisms actively consume energy to increase the specificity of T-cell recognition. An important theoretical question arises: how to understand trade-offs and fundamental limits on accuracy, speed, and dissipation (energy consumption). Recent theoretical work suggests that it is always possible to reduce the the error of KPR-based mechanisms by waiting longer and/or consuming more energy. Surprisingly, we find that this is not the case and that there actually exists an optimal point in the speed-energy-accuracy plane for KPR and its generalizations. This work was supported by NIH R35 and Simons MMLS Grant.

  16. Achieving Consensus on Principles of Good Practice for School Health in Independent Schools: A Delphi Study

    ERIC Educational Resources Information Center

    Marshall, Miguel G.; Allegrante, John P.

    2017-01-01

    Background: Although the 8 components of the coordinated school health (CSH) framework have been implemented to various degrees in the nation's public schools, principles of good practice (PGPs) to guide health promotion efforts in independent schools do not exist. The purpose of this study was to generate PGPs and rate their feasibility of…

  17. Use the Good Mind! An Interview with Freida Jacques.

    ERIC Educational Resources Information Center

    Simonelli, Richard

    1997-01-01

    Freida Jacques, Onondaga clan mother, discusses the discipline of the "good mind," which involves becoming aware of your thoughts, examining the intent of your actions, and deciding whether your intent is based on love or fear and anger. Peace and healing must be achieved through forgiveness and respect. Sidebars discuss Native American…

  18. Two high accuracy digital integrators for Rogowski current transducers.

    PubMed

    Luo, Pan-dian; Li, Hong-bin; Li, Zhen-hua

    2014-01-01

    The Rogowski current transducers have been widely used in AC current measurement, but their accuracy is mainly subject to the analog integrators, which have typical problems such as poor long-term stability and being susceptible to environmental conditions. The digital integrators can be another choice, but they cannot obtain a stable and accurate output for the reason that the DC component in original signal can be accumulated, which will lead to output DC drift. Unknown initial conditions can also result in integral output DC offset. This paper proposes two improved digital integrators used in Rogowski current transducers instead of traditional analog integrators for high measuring accuracy. A proportional-integral-derivative (PID) feedback controller and an attenuation coefficient have been applied in improving the Al-Alaoui integrator to change its DC response and get an ideal frequency response. For the special design in the field of digital signal processing, the improved digital integrators have better performance than analog integrators. Simulation models are built for the purpose of verification and comparison. The experiments prove that the designed integrators can achieve higher accuracy than analog integrators in steady-state response, transient-state response, and temperature changing condition.

  19. Two high accuracy digital integrators for Rogowski current transducers

    NASA Astrophysics Data System (ADS)

    Luo, Pan-dian; Li, Hong-bin; Li, Zhen-hua

    2014-01-01

    The Rogowski current transducers have been widely used in AC current measurement, but their accuracy is mainly subject to the analog integrators, which have typical problems such as poor long-term stability and being susceptible to environmental conditions. The digital integrators can be another choice, but they cannot obtain a stable and accurate output for the reason that the DC component in original signal can be accumulated, which will lead to output DC drift. Unknown initial conditions can also result in integral output DC offset. This paper proposes two improved digital integrators used in Rogowski current transducers instead of traditional analog integrators for high measuring accuracy. A proportional-integral-derivative (PID) feedback controller and an attenuation coefficient have been applied in improving the Al-Alaoui integrator to change its DC response and get an ideal frequency response. For the special design in the field of digital signal processing, the improved digital integrators have better performance than analog integrators. Simulation models are built for the purpose of verification and comparison. The experiments prove that the designed integrators can achieve higher accuracy than analog integrators in steady-state response, transient-state response, and temperature changing condition.

  20. Cognitive accuracy and intelligent executive function in the brain and in business.

    PubMed

    Bailey, Charles E

    2007-11-01

    This article reviews research on cognition, language, organizational culture, brain, behavior, and evolution to posit the value of operating with a stable reference point based on cognitive accuracy and a rational bias. Drawing on rational-emotive behavioral science, social neuroscience, and cognitive organizational science on the one hand and a general model of brain and frontal lobe executive function on the other, I suggest implications for organizational success. Cognitive thought processes depend on specific brain structures functioning as effectively as possible under conditions of cognitive accuracy. However, typical cognitive processes in hierarchical business structures promote the adoption and application of subjective organizational beliefs and, thus, cognitive inaccuracies. Applying informed frontal lobe executive functioning to cognition, emotion, and organizational behavior helps minimize the negative effects of indiscriminate application of personal and cultural belief systems to business. Doing so enhances cognitive accuracy and improves communication and cooperation. Organizations operating with cognitive accuracy will tend to respond more nimbly to market pressures and achieve an overall higher level of performance and employee satisfaction.

  1. Clinical decision support systems for improving diagnostic accuracy and achieving precision medicine.

    PubMed

    Castaneda, Christian; Nalley, Kip; Mannion, Ciaran; Bhattacharyya, Pritish; Blake, Patrick; Pecora, Andrew; Goy, Andre; Suh, K Stephen

    2015-01-01

    As research laboratories and clinics collaborate to achieve precision medicine, both communities are required to understand mandated electronic health/medical record (EHR/EMR) initiatives that will be fully implemented in all clinics in the United States by 2015. Stakeholders will need to evaluate current record keeping practices and optimize and standardize methodologies to capture nearly all information in digital format. Collaborative efforts from academic and industry sectors are crucial to achieving higher efficacy in patient care while minimizing costs. Currently existing digitized data and information are present in multiple formats and are largely unstructured. In the absence of a universally accepted management system, departments and institutions continue to generate silos of information. As a result, invaluable and newly discovered knowledge is difficult to access. To accelerate biomedical research and reduce healthcare costs, clinical and bioinformatics systems must employ common data elements to create structured annotation forms enabling laboratories and clinics to capture sharable data in real time. Conversion of these datasets to knowable information should be a routine institutionalized process. New scientific knowledge and clinical discoveries can be shared via integrated knowledge environments defined by flexible data models and extensive use of standards, ontologies, vocabularies, and thesauri. In the clinical setting, aggregated knowledge must be displayed in user-friendly formats so that physicians, non-technical laboratory personnel, nurses, data/research coordinators, and end-users can enter data, access information, and understand the output. The effort to connect astronomical numbers of data points, including '-omics'-based molecular data, individual genome sequences, experimental data, patient clinical phenotypes, and follow-up data is a monumental task. Roadblocks to this vision of integration and interoperability include ethical, legal

  2. Evaluation of registration accuracy between Sentinel-2 and Landsat 8

    NASA Astrophysics Data System (ADS)

    Barazzetti, Luigi; Cuca, Branka; Previtali, Mattia

    2016-08-01

    Starting from June 2015, Sentinel-2A is delivering high resolution optical images (ground resolution up to 10 meters) to provide a global coverage of the Earth's land surface every 10 days. The planned launch of Sentinel-2B along with the integration of Landsat images will provide time series with an unprecedented revisit time indispensable for numerous monitoring applications, in which high resolution multi-temporal information is required. They include agriculture, water bodies, natural hazards to name a few. However, the combined use of multi-temporal images requires an accurate geometric registration, i.e. pixel-to-pixel correspondence for terrain-corrected products. This paper presents an analysis of spatial co-registration accuracy for several datasets of Sentinel-2 and Landsat 8 images distributed all around the world. Images were compared with digital correlation techniques for image matching, obtaining an evaluation of registration accuracy with an affine transformation as geometrical model. Results demonstrate that sub-pixel accuracy was achieved between 10 m resolution Sentinel-2 bands (band 3) and 15 m resolution panchromatic Landsat images (band 8).

  3. How a GNSS Receiver Is Held May Affect Static Horizontal Position Accuracy

    PubMed Central

    Weaver, Steven A.; Ucar, Zennure; Bettinger, Pete; Merry, Krista

    2015-01-01

    understanding of antenna positioning within the receiver to achieve the greatest accuracy during data collection. PMID:25923667

  4. How a GNSS Receiver Is Held May Affect Static Horizontal Position Accuracy.

    PubMed

    Weaver, Steven A; Ucar, Zennure; Bettinger, Pete; Merry, Krista

    2015-01-01

    understanding of antenna positioning within the receiver to achieve the greatest accuracy during data collection.

  5. Good death in Japanese cancer care: a qualitative study.

    PubMed

    Hirai, Kei; Miyashita, Mitsunori; Morita, Tatsuya; Sanjo, Makiko; Uchitomi, Yosuke

    2006-02-01

    One of the most important goals of palliative care is achieving a "good death" or a "good dying process." The primary aim of this study was to identify the components of a Japanese "good death" through qualitative interviews with cancer patients, their families, physicians, and nurses. Semistructured interviews were conducted. Thirteen advanced cancer patients, 10 family members of such patients, 20 physicians, and 20 nurses were recruited from five regional cancer institutions in Japan. Content analysis was applied to answers, and 58 attributes were extracted and classified into 17 categories as follows: Freedom from pain or physical/psychological symptoms, Having a good family relationship, Dying in one's favorite place/environment, Having a good relationship with medical staff, Not being a burden to others, Maintaining dignity, Completion of life, Maintaining a sense of control, Fighting against cancer, Maintaining hope, Not prolonging life, Contributing to others, Control of future, Not being aware of death, Appreciating others, Maintaining pride, and Having faith. The most frequently cited category was "Freedom from pain or physical/psychological symptoms" and the least common was "Having faith." This study identified important components of a good death in Japan. A future quantitative survey is planned to clarify the generalizability of these findings as the primary endpoint of palliative care in Japan.

  6. The challenges of achieving good electrical and mechanical properties when making structural supercapacitors

    NASA Astrophysics Data System (ADS)

    Ciocanel, C.; Browder, C.; Simpson, C.; Colburn, R.

    2013-04-01

    The paper presents results associated with the electro-mechanical characterization of a composite material with power storage capability, identified throughout the paper as a structural supercapacitor. The structural supercapacitor uses electrodes made of carbon fiber weave, a separator made of Celgard 3501, and a solid PEG-based polymer blend electrolyte. To be a viable structural supercapacitor, the material has to have good mechanical and power storage/electrical properties. The literature in this area is inconsistent on which electrical properties are evaluated, and how those properties are assessed. In general, measurements of capacitance or specific capacitance (i.e. capacitance per unit area or per unit volume) are made, without considering other properties such as leakage resistance and equivalent series resistance of the supercapacitor. This paper highlights the significance of these additional electrical properties, discusses the fluctuation of capacitance over time, and proposes methods to improve the stability of the material's electric properties over time.

  7. An automated method for the evaluation of the pointing accuracy of sun-tracking devices

    NASA Astrophysics Data System (ADS)

    Baumgartner, Dietmar J.; Rieder, Harald E.; Pötzi, Werner; Freislich, Heinrich; Strutzmann, Heinz

    2016-04-01

    The accuracy of measurements of solar radiation (direct and diffuse radiation) depends significantly on the accuracy of the operational sun-tracking device. Thus rigid targets for instrument performance and operation are specified for international monitoring networks, such as e.g., the Baseline Surface Radiation Network (BSRN) operating under the auspices of the World Climate Research Program (WCRP). Sun-tracking devices fulfilling these accuracy targets are available from various instrument manufacturers, however none of the commercially available systems comprises a secondary accuracy control system, allowing platform operators to independently validate the pointing accuracy of sun-tracking sensors during operation. Here we present KSO-STREAMS (KSO-SunTRackEr Accuracy Monitoring System), a fully automated, system independent and cost-effective method for evaluating the pointing accuracy of sun-tracking devices. We detail the monitoring system setup, its design and specifications and results from its application to the sun-tracking system operated at the Austrian RADiation network (ARAD) site Kanzelhöhe Observatory (KSO). Results from KSO-STREAMS (for mid-March to mid-June 2015) show that the tracking accuracy of the device operated at KSO lies well within BSRN specifications (i.e. 0.1 degree accuracy). We contrast results during clear-sky and partly cloudy conditions documenting sun-tracking performance at manufacturer specified accuracies for active tracking (0.02 degrees) and highlight accuracies achieved during passive tracking i.e. periods with less than 300 W m-2 direct radiation. Furthermore we detail limitations to tracking surveillance during overcast conditions and periods of partial solar limb coverage by clouds.

  8. Accuracy requirements of optical linear algebra processors in adaptive optics imaging systems

    NASA Technical Reports Server (NTRS)

    Downie, John D.; Goodman, Joseph W.

    1989-01-01

    The accuracy requirements of optical processors in adaptive optics systems are determined by estimating the required accuracy in a general optical linear algebra processor (OLAP) that results in a smaller average residual aberration than that achieved with a conventional electronic digital processor with some specific computation speed. Special attention is given to an error analysis of a general OLAP with regard to the residual aberration that is created in an adaptive mirror system by the inaccuracies of the processor, and to the effect of computational speed of an electronic processor on the correction. Results are presented on the ability of an OLAP to compete with a digital processor in various situations.

  9. Correlates of Academic Procrastination and Mathematics Achievement of University Undergraduate Students

    ERIC Educational Resources Information Center

    Akinsola, Mojeed Kolawole; Tella, Adedeji; Tella, Adeyinka

    2007-01-01

    Procrastination is now a common phenomenon among students, particularly those at the higher level. And this is doing more harm to their academic achievement than good. Therefore, this study examined the correlates between academic procrastination and mathematics achievement among the university mathematics undergraduate students. The study used a…

  10. Signal processing for order 10 PM accuracy displacement metrology in real-world scientific applications

    NASA Astrophysics Data System (ADS)

    Halverson, Peter G.; Loya, Frank M.

    2017-11-01

    Projects such as the Space Interferometry Mission (SIM) [1] and Terrestrial Planet Finder (TPF) [2] rely heavily on sub-nanometer accuracy metrology systems to define their optical paths and geometries. The James Web Space Telescope (JWST) is using this metrology in a cryogenic dilatometer for characterizing material properties (thermal expansion, creep) of optical materials. For all these projects, a key issue has been the reliability and stability of the electronics that convert displacement metrology signals into real-time distance determinations. A particular concern is the behavior of the electronics in situations where laser heterodyne signals are weak or noisy and subject to abrupt Doppler shifts due to vibrations or the slewing of motorized optics. A second concern is the long-term (hours to days) stability of the distance measurements under conditions of drifting laser power and ambient temperature. This paper describes heterodyne displacement metrology gauge signal processing methods that achieve satisfactory robustness against low signal strength and spurious signals, and good long-term stability. We have a proven displacement-measuring approach that is useful not only to space-optical projects at JPL, but also to the wider field of distance measurements.

  11. Measuring true localization accuracy in super resolution microscopy with DNA-origami nanostructures

    NASA Astrophysics Data System (ADS)

    Reuss, Matthias; Fördős, Ferenc; Blom, Hans; Öktem, Ozan; Högberg, Björn; Brismar, Hjalmar

    2017-02-01

    A common method to assess the performance of (super resolution) microscopes is to use the localization precision of emitters as an estimate for the achieved resolution. Naturally, this is widely used in super resolution methods based on single molecule stochastic switching. This concept suffers from the fact that it is hard to calibrate measures against a real sample (a phantom), because true absolute positions of emitters are almost always unknown. For this reason, resolution estimates are potentially biased in an image since one is blind to true position accuracy, i.e. deviation in position measurement from true positions. We have solved this issue by imaging nanorods fabricated with DNA-origami. The nanorods used are designed to have emitters attached at each end in a well-defined and highly conserved distance. These structures are widely used to gauge localization precision. Here, we additionally determined the true achievable localization accuracy and compared this figure of merit to localization precision values for two common super resolution microscope methods STED and STORM.

  12. Accuracy and Reliability Assessment of CT and MR Perfusion Analysis Software Using a Digital Phantom

    PubMed Central

    Christensen, Soren; Sasaki, Makoto; Østergaard, Leif; Shirato, Hiroki; Ogasawara, Kuniaki; Wintermark, Max; Warach, Steven

    2013-01-01

    Purpose: To design a digital phantom data set for computed tomography (CT) perfusion and perfusion-weighted imaging on the basis of the widely accepted tracer kinetic theory in which the true values of cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT), and tracer arrival delay are known and to evaluate the accuracy and reliability of postprocessing programs using this digital phantom. Materials and Methods: A phantom data set was created by generating concentration-time curves reflecting true values for CBF (2.5–87.5 mL/100 g per minute), CBV (1.0–5.0 mL/100 g), MTT (3.4–24 seconds), and tracer delays (0–3.0 seconds). These curves were embedded in human brain images. The data were analyzed by using 13 algorithms each for CT and magnetic resonance (MR), including five commercial vendors and five academic programs. Accuracy was assessed by using the Pearson correlation coefficient (r) for true values. Delay-, MTT-, or CBV-dependent errors and correlations between time to maximum of residue function (Tmax) were also evaluated. Results: In CT, CBV was generally well reproduced (r > 0.9 in 12 algorithms), but not CBF and MTT (r > 0.9 in seven and four algorithms, respectively). In MR, good correlation (r > 0.9) was observed in one-half of commercial programs, while all academic algorithms showed good correlations for all parameters. Most algorithms had delay-dependent errors, especially for commercial software, as well as CBV dependency for CBF or MTT calculation and MTT dependency for CBV calculation. Correlation was good in Tmax except for one algorithm. Conclusion: The digital phantom readily evaluated the accuracy and characteristics of the CT and MR perfusion analysis software. All commercial programs had delay-induced errors and/or insufficient correlations with true values, while academic programs for MR showed good correlations with true values. © RSNA, 2012 Supplemental material: http

  13. Time series models of environmental exposures: Good predictions or good understanding.

    PubMed

    Barnett, Adrian G; Stephen, Dimity; Huang, Cunrui; Wolkewitz, Martin

    2017-04-01

    Time series data are popular in environmental epidemiology as they make use of the natural experiment of how changes in exposure over time might impact on disease. Many published time series papers have used parameter-heavy models that fully explained the second order patterns in disease to give residuals that have no short-term autocorrelation or seasonality. This is often achieved by including predictors of past disease counts (autoregression) or seasonal splines with many degrees of freedom. These approaches give great residuals, but add little to our understanding of cause and effect. We argue that modelling approaches should rely more on good epidemiology and less on statistical tests. This includes thinking about causal pathways, making potential confounders explicit, fitting a limited number of models, and not over-fitting at the cost of under-estimating the true association between exposure and disease. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Good match exploration for infrared face recognition

    NASA Astrophysics Data System (ADS)

    Yang, Changcai; Zhou, Huabing; Sun, Sheng; Liu, Renfeng; Zhao, Ji; Ma, Jiayi

    2014-11-01

    Establishing good feature correspondence is a critical prerequisite and a challenging task for infrared (IR) face recognition. Recent studies revealed that the scale invariant feature transform (SIFT) descriptor outperforms other local descriptors for feature matching. However, it only uses local appearance information for matching, and hence inevitably leads to a number of false matches. To address this issue, this paper explores global structure information (GSI) among SIFT correspondences, and proposes a new method SIFT-GSI for good match exploration. This is achieved by fitting a smooth mapping function for the underlying correct matches, which involves softassign and deterministic annealing. Quantitative comparisons with state-of-the-art methods on a publicly available IR human face database demonstrate that SIFT-GSI significantly outperforms other methods for feature matching, and hence it is able to improve the reliability of IR face recognition systems.

  15. Accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints.

    PubMed

    Siegenthaler, Andreas; Mlekusch, Sabine; Trelle, Sven; Schliessbach, Juerg; Curatolo, Michele; Eichenberger, Urs

    2012-08-01

    Cervical zygapophysial joint nerve blocks typically are performed with fluoroscopic needle guidance. Descriptions of ultrasound-guided block of these nerves are available, but only one small study compared ultrasound with fluoroscopy, and only for the third occipital nerve. To evaluate the potential usefulness of ultrasound-guidance in clinical practice, studies that determine the accuracy of this technique using a validated control are essential. The aim of this study was to determine the accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints using fluoroscopy as control. Sixty volunteers were studied. Ultrasound-imaging was used to place the needle to the bony target of cervical zygapophysial joint nerve blocks. The levels of needle placement were determined randomly (three levels per volunteer). After ultrasound-guided needle placement and application of 0.2 ml contrast dye, fluoroscopic imaging was performed for later evaluation by a blinded pain physician and considered as gold standard. Raw agreement, chance-corrected agreement κ, and chance-independent agreement Φ between the ultrasound-guided placement and the assessment using fluoroscopy were calculated to quantify accuracy. One hundred eighty needles were placed in 60 volunteers. Raw agreement was 87% (95% CI 81-91%), κ was 0.74 (0.64-0.83), and Φ 0.99 (0.99-0.99). Accuracy varied significantly between the different cervical nerves: it was low for the C7 medial branch, whereas all other levels showed very good accuracy. Ultrasound-imaging is an accurate technique for performing cervical zygapophysial joint nerve blocks in volunteers, except for the medial branch blocks of C7.

  16. Accuracy of acoustic respiration rate monitoring in pediatric patients.

    PubMed

    Patino, Mario; Redford, Daniel T; Quigley, Thomas W; Mahmoud, Mohamed; Kurth, C Dean; Szmuk, Peter

    2013-12-01

    Rainbow acoustic monitoring (RRa) utilizes acoustic technology to continuously and noninvasively determine respiratory rate from an adhesive sensor located on the neck. We sought to validate the accuracy of RRa, by comparing it to capnography, impedance pneumography, and to a reference method of counting breaths in postsurgical children. Continuous respiration rate data were recorded from RRa and capnography. In a subset of patients, intermittent respiration rate from thoracic impedance pneumography was also recorded. The reference method, counted respiratory rate by the retrospective analysis of the RRa, and capnographic waveforms while listening to recorded breath sounds were used to compare respiration rate of both capnography and RRa. Bias, precision, and limits of agreement of RRa compared with capnography and RRa and capnography compared with the reference method were calculated. Tolerance and reliability to the acoustic sensor and nasal cannula were also assessed. Thirty-nine of 40 patients (97.5%) demonstrated good tolerance of the acoustic sensor, whereas 25 of 40 patients (62.5%) demonstrated good tolerance of the nasal cannula. Intermittent thoracic impedance produced erroneous respiratory rates (>50 b·min(-1) from the other methods) on 47% of occasions. The bias ± SD and limits of agreement were -0.30 ± 3.5 b·min(-1) and -7.3 to 6.6 b·min(-1) for RRa compared with capnography; -0.1 ± 2.5 b·min(-1) and -5.0 to 5.0 b·min(-1) for RRa compared with the reference method; and 0.2 ± 3.4 b·min(-1) and -6.8 to 6.7 b·min(-1) for capnography compared with the reference method. When compared to nasal capnography, RRa showed good agreement and similar accuracy and precision but was better tolerated in postsurgical pediatric patients. © 2013 John Wiley & Sons Ltd.

  17. Accuracy Assessment of Digital Surface Models Based on WorldView-2 and ADS80 Stereo Remote Sensing Data

    PubMed Central

    Hobi, Martina L.; Ginzler, Christian

    2012-01-01

    Digital surface models (DSMs) are widely used in forest science to model the forest canopy. Stereo pairs of very high resolution satellite and digital aerial images are relatively new and their absolute accuracy for DSM generation is largely unknown. For an assessment of these input data two DSMs based on a WorldView-2 stereo pair and a ADS80 DSM were generated with photogrammetric instruments. Rational polynomial coefficients (RPCs) are defining the orientation of the WorldView-2 satellite images, which can be enhanced with ground control points (GCPs). Thus two WorldView-2 DSMs were distinguished: a WorldView-2 RPCs-only DSM and a WorldView-2 GCP-enhanced RPCs DSM. The accuracy of the three DSMs was estimated with GPS measurements, manual stereo-measurements, and airborne laser scanning data (ALS). With GCP-enhanced RPCs the WorldView-2 image orientation could be optimised to a root mean square error (RMSE) of 0.56 m in planimetry and 0.32 m in height. This improvement in orientation allowed for a vertical median error of −0.24 m for the WorldView-2 GCP-enhanced RPCs DSM in flat terrain. Overall, the DSM based on ADS80 images showed the highest accuracy of the three models with a median error of 0.08 m over bare ground. As the accuracy of a DSM varies with land cover three classes were distinguished: herb and grass, forests, and artificial areas. The study suggested the ADS80 DSM to best model actual surface height in all three land cover classes, with median errors <1.1 m. The WorldView-2 GCP-enhanced RPCs model achieved good accuracy, too, with median errors of −0.43 m for the herb and grass vegetation and −0.26 m for artificial areas. Forested areas emerged as the most difficult land cover type for height modelling; still, with median errors of −1.85 m for the WorldView-2 GCP-enhanced RPCs model and −1.12 m for the ADS80 model, the input data sets evaluated here are quite promising for forest canopy modelling. PMID:22778645

  18. Accuracy assessment of digital surface models based on WorldView-2 and ADS80 stereo remote sensing data.

    PubMed

    Hobi, Martina L; Ginzler, Christian

    2012-01-01

    Digital surface models (DSMs) are widely used in forest science to model the forest canopy. Stereo pairs of very high resolution satellite and digital aerial images are relatively new and their absolute accuracy for DSM generation is largely unknown. For an assessment of these input data two DSMs based on a WorldView-2 stereo pair and a ADS80 DSM were generated with photogrammetric instruments. Rational polynomial coefficients (RPCs) are defining the orientation of the WorldView-2 satellite images, which can be enhanced with ground control points (GCPs). Thus two WorldView-2 DSMs were distinguished: a WorldView-2 RPCs-only DSM and a WorldView-2 GCP-enhanced RPCs DSM. The accuracy of the three DSMs was estimated with GPS measurements, manual stereo-measurements, and airborne laser scanning data (ALS). With GCP-enhanced RPCs the WorldView-2 image orientation could be optimised to a root mean square error (RMSE) of 0.56 m in planimetry and 0.32 m in height. This improvement in orientation allowed for a vertical median error of -0.24 m for the WorldView-2 GCP-enhanced RPCs DSM in flat terrain. Overall, the DSM based on ADS80 images showed the highest accuracy of the three models with a median error of 0.08 m over bare ground. As the accuracy of a DSM varies with land cover three classes were distinguished: herb and grass, forests, and artificial areas. The study suggested the ADS80 DSM to best model actual surface height in all three land cover classes, with median errors <1.1 m. The WorldView-2 GCP-enhanced RPCs model achieved good accuracy, too, with median errors of -0.43 m for the herb and grass vegetation and -0.26 m for artificial areas. Forested areas emerged as the most difficult land cover type for height modelling; still, with median errors of -1.85 m for the WorldView-2 GCP-enhanced RPCs model and -1.12 m for the ADS80 model, the input data sets evaluated here are quite promising for forest canopy modelling.

  19. A proposal for limited criminal liability in high-accuracy endoscopic sinus surgery.

    PubMed

    Voultsos, P; Casini, M; Ricci, G; Tambone, V; Midolo, E; Spagnolo, A G

    2017-02-01

    The aim of the present study is to propose legal reform limiting surgeons' criminal liability in high-accuracy and high-risk surgery such as endoscopic sinus surgery (ESS). The study includes a review of the medical literature, focusing on identifying and examining reasons why ESS carries a very high risk of serious complications related to inaccurate surgical manoeuvers and reviewing British and Italian legal theory and case-law on medical negligence, especially with regard to Italian Law 189/2012 (so called "Balduzzi" Law). It was found that serious complications due to inaccurate surgical manoeuvers may occur in ESS regardless of the skill, experience and prudence/diligence of the surgeon. Subjectivity should be essential to medical negligence, especially regarding high-accuracy surgery. Italian Law 189/2012 represents a good basis for the limitation of criminal liability resulting from inaccurate manoeuvres in high-accuracy surgery such as ESS. It is concluded that ESS surgeons should be relieved of criminal liability in cases of simple/ordinary negligence where guidelines have been observed. © Copyright by Società Italiana di Otorinolaringologia e Chirurgia Cervico-Facciale, Rome, Italy.

  20. Accuracy Analysis for Finite-Volume Discretization Schemes on Irregular Grids

    NASA Technical Reports Server (NTRS)

    Diskin, Boris; Thomas, James L.

    2010-01-01

    A new computational analysis tool, downscaling test, is introduced and applied for studying the convergence rates of truncation and discretization errors of nite-volume discretization schemes on general irregular (e.g., unstructured) grids. The study shows that the design-order convergence of discretization errors can be achieved even when truncation errors exhibit a lower-order convergence or, in some cases, do not converge at all. The downscaling test is a general, efficient, accurate, and practical tool, enabling straightforward extension of verification and validation to general unstructured grid formulations. It also allows separate analysis of the interior, boundaries, and singularities that could be useful even in structured-grid settings. There are several new findings arising from the use of the downscaling test analysis. It is shown that the discretization accuracy of a common node-centered nite-volume scheme, known to be second-order accurate for inviscid equations on triangular grids, degenerates to first order for mixed grids. Alternative node-centered schemes are presented and demonstrated to provide second and third order accuracies on general mixed grids. The local accuracy deterioration at intersections of tangency and in flow/outflow boundaries is demonstrated using the DS tests tailored to examining the local behavior of the boundary conditions. The discretization-error order reduction within inviscid stagnation regions is demonstrated. The accuracy deterioration is local, affecting mainly the velocity components, but applies to any order scheme.

  1. Evaluating the Discriminant Accuracy of a Grammatical Measure With Spanish-Speaking Children

    PubMed Central

    Gutiérrez-Clellen, Vera F.; Restrepo, M. Adelaida; Simón-Cereijido, Gabriela

    2012-01-01

    Purpose The purpose of this study was to evaluate the discriminant accuracy of a grammatical measure for the identification of language impairment in Latino Spanish-speaking children. The authors hypothesized that if exposure to and use of English as a second language have an effect on the first language, bilingual children might exhibit lower rates of grammatical accuracy than their peers and be more likely to be misclassified. Method Eighty children with typical language development and 80 with language impairment were sampled from 4 different geographical regions and compared using linear discriminant function analysis. Results Results indicated fair-to-good sensitivity from 4;0 to 5;1 years, good sensitivity from 5;2 to 5;11 years, and poor sensitivity above age 6 years. The discriminant functions derived from the exploratory studies were able to predict group membership in confirmatory analyses with fair-to-excellent sensitivity up to age 6 years. Children who were bilingual did not show lower scores and were not more likely to be misclassified compared with their Spanish-only peers. Conclusions The measure seems to be appropriate for identifying language impairment in either Spanish-dominant or Spanish-only speakers between 4 and 6 years of age. However, for older children, supplemental testing is necessary. PMID:17197491

  2. Accuracy of stream habitat interpolations across spatial scales

    USGS Publications Warehouse

    Sheehan, Kenneth R.; Welsh, Stuart A.

    2013-01-01

    Stream habitat data are often collected across spatial scales because relationships among habitat, species occurrence, and management plans are linked at multiple spatial scales. Unfortunately, scale is often a factor limiting insight gained from spatial analysis of stream habitat data. Considerable cost is often expended to collect data at several spatial scales to provide accurate evaluation of spatial relationships in streams. To address utility of single scale set of stream habitat data used at varying scales, we examined the influence that data scaling had on accuracy of natural neighbor predictions of depth, flow, and benthic substrate. To achieve this goal, we measured two streams at gridded resolution of 0.33 × 0.33 meter cell size over a combined area of 934 m2 to create a baseline for natural neighbor interpolated maps at 12 incremental scales ranging from a raster cell size of 0.11 m2 to 16 m2 . Analysis of predictive maps showed a logarithmic linear decay pattern in RMSE values in interpolation accuracy for variables as resolution of data used to interpolate study areas became coarser. Proportional accuracy of interpolated models (r2 ) decreased, but it was maintained up to 78% as interpolation scale moved from 0.11 m2 to 16 m2 . Results indicated that accuracy retention was suitable for assessment and management purposes at various scales different from the data collection scale. Our study is relevant to spatial modeling, fish habitat assessment, and stream habitat management because it highlights the potential of using a single dataset to fulfill analysis needs rather than investing considerable cost to develop several scaled datasets.

  3. Employment of sawtooth-shaped-function excitation signal and oversampling for improving resistance measurement accuracy

    NASA Astrophysics Data System (ADS)

    Lin, Ling; Li, Shujuan; Yan, Wenjuan; Li, Gang

    2016-10-01

    In order to achieve higher measurement accuracy of routine resistance without increasing the complexity and cost of the system circuit of existing methods, this paper presents a novel method that exploits a shaped-function excitation signal and oversampling technology. The excitation signal source for resistance measurement is modulated by the sawtooth-shaped-function signal, and oversampling technology is employed to increase the resolution and the accuracy of the measurement system. Compared with the traditional method of using constant amplitude excitation signal, this method can effectively enhance the measuring accuracy by almost one order of magnitude and reduce the root mean square error by 3.75 times under the same measurement conditions. The results of experiments show that the novel method can attain the aim of significantly improve the measurement accuracy of resistance on the premise of not increasing the system cost and complexity of the circuit, which is significantly valuable for applying in electronic instruments.

  4. Accuracy and precision evaluation of seven self-monitoring blood glucose systems.

    PubMed

    Kuo, Chih-Yi; Hsu, Cheng-Teng; Ho, Cheng-Shiao; Su, Ting-En; Wu, Ming-Hsun; Wang, Chau-Jong

    2011-05-01

    Self-monitoring blood glucose (SMBG) systems play a critical role in management of diabetes. SMBG systems should at least meet the minimal requirement of the World Health Organization's ISO 15197:2003. For tight glycemic control, a tighter accuracy requirement is needed. Seven SMBG systems were evaluated for accuracy and precision: Bionime Rightest(™) GM550 (Bionime Corp., Dali City, Taiwan), Accu-Chek(®) Performa (Roche Diagnostics, Indianapolis, IN), OneTouch(®) Ultra(®)2 (LifeScan Inc., Milpitas, CA), MediSense(®) Optium(™) Xceed (Abbott Diabetes Care Inc., Alameda, CA), Medisafe (TERUMO Corp., Tokyo, Japan), Fora(®) TD4227 (Taidac Technology Corp., Wugu Township, Taiwan), and Ascensia Contour(®) (Bayer HealthCare LLC, Mishawaka, IN). The 107 participants (44 men and 63 women) were between 23 and 91 years old. The analytical results of seven SMBG systems were compared with those of plasma analyzed with the hexokinase method (Olympus AU640, Olympus America Inc., Center Valley, PA). The imprecision of the seven blood glucose meters ranged from 1.1% to 4.7%. Three of the seven blood glucose meters (42.9%) fulfilled the minimum accuracy criteria of ISO 15197:2003. The mean absolute relative error value for each blood glucose meter was calculated and ranged from 6.5% to 12.0%. More than 40% of evaluated SMBG systems meet the minimal accuracy criteria requirement of ISO 15197:2003. However, considering tighter criteria for accuracy of ±15%, only the Bionime Rightest GM550 meets this requirement. Because SMBG systems play a critical role in management of diabetes, manufacturers have to strive to improve accuracy and precision and to ensure the good quality of blood glucose meters and test strips.

  5. One of the Good Guys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiley, H. S.

    I was talking with some younger colleagues at a meeting last month when the subject of career goals came up. These colleagues were successful in that they had recently received tenure at top research universities and had some grants and good students. Thus, the early career pressure to simply survive was gone. So now what motivated them? Solving challenging and significant scientific problems was at the top of their lists. Interestingly, they were also motivated by a desire to become one of the “good guys” in science. The fact that being an important contributor to the scientific community can bemore » fulfilling should not come as a surprise to anyone. However, what I do consider surprising is how rarely this seems to be discussed with students and postdocs. What we do discuss are either those issues that are fundamental aspects of the job (get a grant, get tenure, do research in an important field) or those that are important to our institutions. Knowing how to do our jobs well is indeed essential for any kind of professional success. However, achieving the right balance in our ambitions is also important for our happiness.« less

  6. Accuracy of refractive outcomes in myopic and hyperopic laser in situ keratomileusis: Manifest versus aberrometric refraction.

    PubMed

    Reinstein, Dan Z; Morral, Merce; Gobbe, Marine; Archer, Timothy J

    2012-11-01

    To compare the achieved refractive accuracy of laser in situ keratomileusis (LASIK) performed based on manifest refraction with the predicted accuracy that would have been achieved using WASCA aberrometric refraction with and without Seidel correction factor for sphere. London Vision Clinic, London, United Kingdom. Comparative case series. Myopic eyes and hyperopic eyes had LASIK based on manifest refraction. Two aberrometric refractions were obtained preoperatively: Seidel, which includes spherical aberration in the sphere calculation, and non-Seidel. Bland-Altman plots were used to show the agreement between aberrometric and manifest refractions. Predicted LASIK outcomes had aberrometric refraction been used were modeled by shifting the postoperative manifest refraction by the vector difference between the preoperative manifest and aberrometric refractions. This study included 869 myopic eyes and 413 hyperopic eyes. The mean differences (manifest minus aberrometric) in spherical equivalent were +0.03 diopters (D) ± 0.48 (SD) (Seidel aberrometric) and +0.45 ± 0.42 D (non-Seidel aberrometric) for myopia and -0.20 ± 0.39 D and +0.39 ± 0.34 D, respectively, for hyperopia. The mean differences in cylinder magnitude were -0.10 ± 0.27 D and 0.00 ± 0.25 D, respectively. The percentage of eyes within ±0.50 D of the attempted correction was 81% (manifest), 70% (Seidel), and 67% (non-Seidel) for myopia and 71% (manifest), 61% (Seidel), and 64% (non-Seidel) for hyperopia. The achieved refractive accuracy by manifest refraction was better than the predicted accuracy had Seidel or non-Seidel aberrometric refractions been used for surgical planning. Using the Seidel method improved the accuracy in myopic eyes but not in hyperopic eyes. Dr. Reinstein is a consultant to Carl Zeiss Meditec AG and has a proprietary interest in the Artemis technology (Arcscan Inc., Morrison, Colorado, USA) through patents administered by the Cornell Center for Technology Enterprise and

  7. Battery Energy Storage State-of-Charge Forecasting: Models, Optimization, and Accuracy

    DOE PAGES

    Rosewater, David; Ferreira, Summer; Schoenwald, David; ...

    2018-01-25

    Battery energy storage systems (BESS) are a critical technology for integrating high penetration renewable power on an intelligent electrical grid. As limited energy restricts the steady-state operational state-of-charge (SoC) of storage systems, SoC forecasting models are used to determine feasible charge and discharge schedules that supply grid services. Smart grid controllers use SoC forecasts to optimize BESS schedules to make grid operation more efficient and resilient. This study presents three advances in BESS state-of-charge forecasting. First, two forecasting models are reformulated to be conducive to parameter optimization. Second, a new method for selecting optimal parameter values based on operational datamore » is presented. Last, a new framework for quantifying model accuracy is developed that enables a comparison between models, systems, and parameter selection methods. The accuracies achieved by both models, on two example battery systems, with each method of parameter selection are then compared in detail. The results of this analysis suggest variation in the suitability of these models for different battery types and applications. Finally, the proposed model formulations, optimization methods, and accuracy assessment framework can be used to improve the accuracy of SoC forecasts enabling better control over BESS charge/discharge schedules.« less

  8. Dependence of quantitative accuracy of CT perfusion imaging on system parameters

    NASA Astrophysics Data System (ADS)

    Li, Ke; Chen, Guang-Hong

    2017-03-01

    Deconvolution is a popular method to calculate parametric perfusion parameters from four dimensional CT perfusion (CTP) source images. During the deconvolution process, the four dimensional space is squeezed into three-dimensional space by removing the temporal dimension, and a prior knowledge is often used to suppress noise associated with the process. These additional complexities confound the understanding about deconvolution-based CTP imaging system and how its quantitative accuracy depends on parameters and sub-operations involved in the image formation process. Meanwhile, there has been a strong clinical need in answering this question, as physicians often rely heavily on the quantitative values of perfusion parameters to make diagnostic decisions, particularly during an emergent clinical situation (e.g. diagnosis of acute ischemic stroke). The purpose of this work was to develop a theoretical framework that quantitatively relates the quantification accuracy of parametric perfusion parameters with CTP acquisition and post-processing parameters. This goal was achieved with the help of a cascaded systems analysis for deconvolution-based CTP imaging systems. Based on the cascaded systems analysis, the quantitative relationship between regularization strength, source image noise, arterial input function, and the quantification accuracy of perfusion parameters was established. The theory could potentially be used to guide developments of CTP imaging technology for better quantification accuracy and lower radiation dose.

  9. Battery Energy Storage State-of-Charge Forecasting: Models, Optimization, and Accuracy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosewater, David; Ferreira, Summer; Schoenwald, David

    Battery energy storage systems (BESS) are a critical technology for integrating high penetration renewable power on an intelligent electrical grid. As limited energy restricts the steady-state operational state-of-charge (SoC) of storage systems, SoC forecasting models are used to determine feasible charge and discharge schedules that supply grid services. Smart grid controllers use SoC forecasts to optimize BESS schedules to make grid operation more efficient and resilient. This study presents three advances in BESS state-of-charge forecasting. First, two forecasting models are reformulated to be conducive to parameter optimization. Second, a new method for selecting optimal parameter values based on operational datamore » is presented. Last, a new framework for quantifying model accuracy is developed that enables a comparison between models, systems, and parameter selection methods. The accuracies achieved by both models, on two example battery systems, with each method of parameter selection are then compared in detail. The results of this analysis suggest variation in the suitability of these models for different battery types and applications. Finally, the proposed model formulations, optimization methods, and accuracy assessment framework can be used to improve the accuracy of SoC forecasts enabling better control over BESS charge/discharge schedules.« less

  10. Overlay accuracy fundamentals

    NASA Astrophysics Data System (ADS)

    Kandel, Daniel; Levinski, Vladimir; Sapiens, Noam; Cohen, Guy; Amit, Eran; Klein, Dana; Vakshtein, Irina

    2012-03-01

    Currently, the performance of overlay metrology is evaluated mainly based on random error contributions such as precision and TIS variability. With the expected shrinkage of the overlay metrology budget to < 0.5nm, it becomes crucial to include also systematic error contributions which affect the accuracy of the metrology. Here we discuss fundamental aspects of overlay accuracy and a methodology to improve accuracy significantly. We identify overlay mark imperfections and their interaction with the metrology technology, as the main source of overlay inaccuracy. The most important type of mark imperfection is mark asymmetry. Overlay mark asymmetry leads to a geometrical ambiguity in the definition of overlay, which can be ~1nm or less. It is shown theoretically and in simulations that the metrology may enhance the effect of overlay mark asymmetry significantly and lead to metrology inaccuracy ~10nm, much larger than the geometrical ambiguity. The analysis is carried out for two different overlay metrology technologies: Imaging overlay and DBO (1st order diffraction based overlay). It is demonstrated that the sensitivity of DBO to overlay mark asymmetry is larger than the sensitivity of imaging overlay. Finally, we show that a recently developed measurement quality metric serves as a valuable tool for improving overlay metrology accuracy. Simulation results demonstrate that the accuracy of imaging overlay can be improved significantly by recipe setup optimized using the quality metric. We conclude that imaging overlay metrology, complemented by appropriate use of measurement quality metric, results in optimal overlay accuracy.

  11. Accuracy improvements of gyro-based measurement-while-drilling surveying instruments by a laser testing method

    NASA Astrophysics Data System (ADS)

    Li, Rong; Zhao, Jianhui; Li, Fan

    2009-07-01

    Gyroscope used as surveying sensor in the oil industry has been proposed as a good technique for measurement-whiledrilling (MWD) to provide real-time monitoring of the position and the orientation of the bottom hole assembly (BHA).However, drifts in the measurements provided by gyroscope might be prohibitive for the long-term utilization of the sensor. Some usual methods such as zero velocity update procedure (ZUPT) introduced to limit these drifts seem to be time-consuming and with limited effect. This study explored an in-drilling dynamic -alignment (IDA) method for MWD which utilizes gyroscope. During a directional drilling process, there are some minutes in the rotary drilling mode when the drill bit combined with drill pipe are rotated about the spin axis in a certain speed. This speed can be measured and used to determine and limit some drifts of the gyroscope which pay great effort to the deterioration in the long-term performance. A novel laser assembly is designed on the wellhead to count the rotating cycles of the drill pipe. With this provided angular velocity of the drill pipe, drifts of gyroscope measurements are translated into another form that can be easy tested and compensated. That allows better and faster alignment and limited drifts during the navigation process both of which can reduce long-term navigation errors, thus improving the overall accuracy in INS-based MWD system. This article concretely explores the novel device on the wellhead designed to test the rotation of the drill pipe. It is based on laser testing which is simple and not expensive by adding a laser emitter to the existing drilling equipment. Theoretical simulations and analytical approximations exploring the IDA idea have shown improvement in the accuracy of overall navigation and reduction in the time required to achieve convergence. Gyroscope accuracy along the axis is mainly improved. It is suggested to use the IDA idea in the rotary mode for alignment. Several other

  12. Silver Coating for High-Mass-Accuracy Imaging Mass Spectrometry of Fingerprints on Nanostructured Silicon.

    PubMed

    Guinan, Taryn M; Gustafsson, Ove J R; McPhee, Gordon; Kobus, Hilton; Voelcker, Nicolas H

    2015-11-17

    Nanostructure imaging mass spectrometry (NIMS) using porous silicon (pSi) is a key technique for molecular imaging of exogenous and endogenous low molecular weight compounds from fingerprints. However, high-mass-accuracy NIMS can be difficult to achieve as time-of-flight (ToF) mass analyzers, which dominate the field, cannot sufficiently compensate for shifts in measured m/z values. Here, we show internal recalibration using a thin layer of silver (Ag) sputter-coated onto functionalized pSi substrates. NIMS peaks for several previously reported fingerprint components were selected and mass accuracy was compared to theoretical values. Mass accuracy was improved by more than an order of magnitude in several cases. This straightforward method should form part of the standard guidelines for NIMS studies for spatial characterization of small molecules.

  13. Contrast-enhanced small-animal PET/CT in cancer research: strong improvement of diagnostic accuracy without significant alteration of quantitative accuracy and NEMA NU 4-2008 image quality parameters.

    PubMed

    Lasnon, Charline; Quak, Elske; Briand, Mélanie; Gu, Zheng; Louis, Marie-Hélène; Aide, Nicolas

    2013-01-17

    The use of iodinated contrast media in small-animal positron emission tomography (PET)/computed tomography (CT) could improve anatomic referencing and tumor delineation but may introduce inaccuracies in the attenuation correction of the PET images. This study evaluated the diagnostic performance and accuracy of quantitative values in contrast-enhanced small-animal PET/CT (CEPET/CT) as compared to unenhanced small animal PET/CT (UEPET/CT). Firstly, a NEMA NU 4-2008 phantom (filled with 18F-FDG or 18F-FDG plus contrast media) and a homemade phantom, mimicking an abdominal tumor surrounded by water or contrast media, were used to evaluate the impact of iodinated contrast media on the image quality parameters and accuracy of quantitative values for a pertinent-sized target. Secondly, two studies in 22 abdominal tumor-bearing mice and rats were performed. The first animal experiment studied the impact of a dual-contrast media protocol, comprising the intravenous injection of a long-lasting contrast agent mixed with 18F-FDG and the intraperitoneal injection of contrast media, on tumor delineation and the accuracy of quantitative values. The second animal experiment compared the diagnostic performance and quantitative values of CEPET/CT versus UEPET/CT by sacrificing the animals after the tracer uptake period and imaging them before and after intraperitoneal injection of contrast media. There was minimal impact on IQ parameters (%SDunif and spillover ratios in air and water) when the NEMA NU 4-2008 phantom was filled with 18F-FDG plus contrast media. In the homemade phantom, measured activity was similar to true activity (-0.02%) and overestimated by 10.30% when vials were surrounded by water or by an iodine solution, respectively. The first animal experiment showed excellent tumor delineation and a good correlation between small-animal (SA)-PET and ex vivo quantification (r2 = 0.87, P < 0.0001). The second animal experiment showed a good correlation between CEPET/CT and

  14. Climate Change Accuracy: Requirements and Economic Value

    NASA Astrophysics Data System (ADS)

    Wielicki, B. A.; Cooke, R.; Mlynczak, M. G.; Lukashin, C.; Thome, K. J.; Baize, R. R.

    2014-12-01

    Higher than normal accuracy is required to rigorously observe decadal climate change. But what level is needed? How can this be quantified? This presentation will summarize a new more rigorous and quantitative approach to determining the required accuracy for climate change observations (Wielicki et al., 2013, BAMS). Most current global satellite observations cannot meet this accuracy level. A proposed new satellite mission to resolve this challenge is CLARREO (Climate Absolute Radiance and Refractivity Observatory). CLARREO is designed to achieve advances of a factor of 10 for reflected solar spectra and a factor of 3 to 5 for thermal infrared spectra (Wielicki et al., Oct. 2013 BAMS). The CLARREO spectrometers are designed to serve as SI traceable benchmarks for the Global Satellite Intercalibration System (GSICS) and to greatly improve the utility of a wide range of LEO and GEO infrared and reflected solar passive satellite sensors for climate change observations (e.g. CERES, MODIS, VIIIRS, CrIS, IASI, Landsat, SPOT, etc). Providing more accurate decadal change trends can in turn lead to more rapid narrowing of key climate science uncertainties such as cloud feedback and climate sensitivity. A study has been carried out to quantify the economic benefits of such an advance as part of a rigorous and complete climate observing system. The study concludes that the economic value is $12 Trillion U.S. dollars in Net Present Value for a nominal discount rate of 3% (Cooke et al. 2013, J. Env. Sys. Dec.). A brief summary of these two studies and their implications for the future of climate science will be presented.

  15. Improvement on Timing Accuracy of LIDAR for Remote Sensing

    NASA Astrophysics Data System (ADS)

    Zhou, G.; Huang, W.; Zhou, X.; Huang, Y.; He, C.; Li, X.; Zhang, L.

    2018-05-01

    The traditional timing discrimination technique for laser rangefinding in remote sensing, which is lower in measurement performance and also has a larger error, has been unable to meet the high precision measurement and high definition lidar image. To solve this problem, an improvement of timing accuracy based on the improved leading-edge timing discrimination (LED) is proposed. Firstly, the method enables the corresponding timing point of the same threshold to move forward with the multiple amplifying of the received signal. Then, timing information is sampled, and fitted the timing points through algorithms in MATLAB software. Finally, the minimum timing error is calculated by the fitting function. Thereby, the timing error of the received signal from the lidar is compressed and the lidar data quality is improved. Experiments show that timing error can be significantly reduced by the multiple amplifying of the received signal and the algorithm of fitting the parameters, and a timing accuracy of 4.63 ps is achieved.

  16. An apparent contradiction: increasing variability to achieve greater precision?

    PubMed

    Rosenblatt, Noah J; Hurt, Christopher P; Latash, Mark L; Grabiner, Mark D

    2014-02-01

    To understand the relationship between variability of foot placement in the frontal plane and stability of gait patterns, we explored how constraining mediolateral foot placement during walking affects the structure of kinematic variance in the lower-limb configuration space during the swing phase of gait. Ten young subjects walked under three conditions: (1) unconstrained (normal walking), (2) constrained (walking overground with visual guides for foot placement to achieve the measured unconstrained step width) and, (3) beam (walking on elevated beams spaced to achieve the measured unconstrained step width). The uncontrolled manifold analysis of the joint configuration variance was used to quantify two variance components, one that did not affect the mediolateral trajectory of the foot in the frontal plane ("good variance") and one that affected this trajectory ("bad variance"). Based on recent studies, we hypothesized that across conditions (1) the index of the synergy stabilizing the mediolateral trajectory of the foot (the normalized difference between the "good variance" and "bad variance") would systematically increase and (2) the changes in the synergy index would be associated with a disproportionate increase in the "good variance." Both hypotheses were confirmed. We conclude that an increase in the "good variance" component of the joint configuration variance may be an effective method of ensuring high stability of gait patterns during conditions requiring increased control of foot placement, particularly if a postural threat is present. Ultimately, designing interventions that encourage a larger amount of "good variance" may be a promising method of improving stability of gait patterns in populations such as older adults and neurological patients.

  17. Data for Program Management: An Accuracy Assessment of Data Collected in Household Registers by Community Health Workers in Southern Kayonza, Rwanda.

    PubMed

    Mitsunaga, Tisha; Hedt-Gauthier, Bethany L; Ngizwenayo, Elias; Farmer, Didi Bertrand; Gaju, Erick; Drobac, Peter; Basinga, Paulin; Hirschhorn, Lisa; Rich, Michael L; Winch, Peter J; Ngabo, Fidele; Mugeni, Cathy

    2015-08-01

    Community health workers (CHWs) collect data for routine services, surveys and research in their communities. However, quality of these data is largely unknown. Utilizing poor quality data can result in inefficient resource use, misinformation about system gaps, and poor program management and effectiveness. This study aims to measure CHW data accuracy, defined as agreement between household registers compared to household member interview and client records in one district in Eastern province, Rwanda. We used cluster-lot quality assurance sampling to randomly sample six CHWs per cell and six households per CHW. We classified cells as having 'poor' or 'good' accuracy for household registers for five indicators, calculating point estimates of percent of households with accurate data by health center. We evaluated 204 CHW registers and 1,224 households for accuracy across 34 cells in southern Kayonza. Point estimates across health centers ranged from 79 to 100% for individual indicators and 61 to 72% for the composite indicator. Recording error appeared random for all but the widely under-reported number of women on modern family planning method. Overall, accuracy was largely 'good' across cells, with varying results by indicator. Program managers should identify optimum thresholds for 'good' data quality and interventions to reach them according to data use. Decreasing variability and improving quality will facilitate potential of these routinely-collected data to be more meaningful for community health program management. We encourage further studies assessing CHW data quality and the impact training, supervision and other strategies have on improving it.

  18. Patient-specific instrument can achieve same accuracy with less resection time than navigation assistance in periacetabular pelvic tumor surgery: a cadaveric study.

    PubMed

    Wong, Kwok-Chuen; Sze, Kwan-Yik; Wong, Irene Oi-Ling; Wong, Chung-Ming; Kumta, Shekhar-Madhukar

    2016-02-01

    Inaccurate resection in pelvic tumors can result in compromised margins with increase local recurrence. Navigation-assisted and patient-specific instrument (PSI) techniques have recently been reported in assisting pelvic tumor surgery with the tendency of improving surgical accuracy. We examined and compared the accuracy of transferring a virtual pelvic resection plan to actual surgery using navigation-assisted or PSI technique in a cadaver study. We performed CT scan in twelve cadaveric bodies including whole pelvic bones. Either supraacetabular or partial acetabular resection was virtually planned in a hemipelvis using engineering software. The virtual resection plan was transferred to a CT-based navigation system or was used for design and fabrication of PSI. Pelvic resections were performed using navigation assistance in six cadavers and PSI in another six. Post-resection images were co-registered with preoperative planning for comparative analysis of resection accuracy in the two techniques. The mean average deviation error from the planned resection was no different ([Formula: see text]) for the navigation and the PSI groups: 1.9 versus 1.4 mm, respectively. The mean time required for the bone resection was greater ([Formula: see text]) for the navigation group than for the PSI group: 16.2 versus 1.1 min, respectively. In simulated periacetabular pelvic tumor resections, PSI technique enabled surgeons to reproduce the virtual surgical plan with similar accuracy but with less bone resection time when compared with navigation assistance. Further studies are required to investigate the clinical benefits of PSI technique in pelvic tumor surgery.

  19. New perspectives for high accuracy SLR with second generation geodesic satellites

    NASA Technical Reports Server (NTRS)

    Lund, Glenn

    1993-01-01

    This paper reports on the accuracy limitations imposed by geodesic satellite signatures, and on the potential for achieving millimetric performances by means of alternative satellite concepts and an optimized 2-color system tradeoff. Long distance laser ranging, when performed between a ground (emitter/receiver) station and a distant geodesic satellite, is now reputed to enable short arc trajectory determinations to be achieved with an accuracy of 1 to 2 centimeters. This state-of-the-art accuracy is limited principally by the uncertainties inherent to single-color atmospheric path length correction. Motivated by the study of phenomena such as postglacial rebound, and the detailed analysis of small-scale volcanic and strain deformations, the drive towards millimetric accuracies will inevitably be felt. With the advent of short pulse (less than 50 ps) dual wavelength ranging, combined with adequate detection equipment (such as a fast-scanning streak camera or ultra-fast solid-state detectors) the atmospheric uncertainty could potentially be reduced to the level of a few millimeters, thus, exposing other less significant error contributions, of which by far the most significant will then be the morphology of the retroreflector satellites themselves. Existing geodesic satellites are simply dense spheres, several 10's of cm in diameter, encrusted with a large number (426 in the case of LAGEOS) of small cube-corner reflectors. A single incident pulse, thus, results in a significant number of randomly phased, quasi-simultaneous return pulses. These combine coherently at the receiver to produce a convolved interference waveform which cannot, on a shot to shot basis, be accurately and unambiguously correlated to the satellite center of mass. This paper proposes alternative geodesic satellite concepts, based on the use of a very small number of cube-corner retroreflectors, in which the above difficulties are eliminated while ensuring, for a given emitted pulse, the return

  20. Perceptual and Acoustic Analyses of Good Voice Quality in Male Radio Performers.

    PubMed

    Warhurst, Samantha; Madill, Catherine; McCabe, Patricia; Ternström, Sten; Yiu, Edwin; Heard, Robert

    2017-03-01

    Good voice quality is an asset to professional voice users, including radio performers. We examined whether (1) voices could be reliably categorized as good for the radio and (2) these categories could be predicted using acoustic measures. Male radio performers (n = 24) and age-matched male controls performed "The Rainbow Passage" as if presenting on the radio. Voice samples were rated using a three-stage paired-comparison paradigm by 51 naive listeners and perceptual categories were identified (Study 1), and then analyzed for fundamental frequency, long-term average spectrum, cepstral peak prominence, and pause or spoken-phrase duration (Study 2). Study 1: Good inter-judge reliability was found for perceptual judgments of the best 15 voices (good for radio category, 14/15 = radio performers), but agreement on the remaining 33 voices (unranked category) was poor. Study 2: Discriminant function analyses showed that the SD standard deviation of sounded portion duration, equivalent sound level, and smoothed cepstral peak prominence predicted membership of categories with moderate accuracy (R 2  = 0.328). Radio performers are heterogeneous for voice quality; good voice quality was judged reliably in only 14 out of 24 radio performers. Current acoustic analyses detected some of the relevant signal properties that were salient in these judgments. More refined perceptual analysis and the use of other perceptual methods might provide more information on the complex nature of judging good voices. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  1. Block Adjustment and Image Matching of WORLDVIEW-3 Stereo Pairs and Accuracy Evaluation

    NASA Astrophysics Data System (ADS)

    Zuo, C.; Xiao, X.; Hou, Q.; Li, B.

    2018-05-01

    WorldView-3, as a high-resolution commercial earth observation satellite, which is launched by Digital Global, provides panchromatic imagery of 0.31 m resolution. The positioning accuracy is less than 3.5 meter CE90 without ground control, which can use for large scale topographic mapping. This paper presented the block adjustment for WorldView-3 based on RPC model and achieved the accuracy of 1 : 2000 scale topographic mapping with few control points. On the base of stereo orientation result, this paper applied two kinds of image matching algorithm for DSM extraction: LQM and SGM. Finally, this paper compared the accuracy of the point cloud generated by the two image matching methods with the reference data which was acquired by an airborne laser scanner. The results showed that the RPC adjustment model of WorldView-3 image with small number of GCPs could satisfy the requirement of Chinese Surveying and Mapping regulations for 1 : 2000 scale topographic maps. And the point cloud result obtained through WorldView-3 stereo image matching had higher elevation accuracy, the RMS error of elevation for bare ground area is 0.45 m, while for buildings the accuracy can almost reach 1 meter.

  2. Accuracy of routine magnetic resonance imaging in meniscal and ligamentous injuries of the knee: comparison with arthroscopy

    PubMed Central

    Behairy, Noha H.; Dorgham, Mohsen A.

    2008-01-01

    The aim of this study was to detect the accuracy of routine magnetic resonance imaging (MRI) done in different centres and its agreement with arthroscopy in meniscal and ligamentous injuries of the knee. We prospectively examined 70 patients ranging in age between 22 and 59 years. History taking, plain X-ray, clinical examination, routine MRI and arthroscopy were done for all patients. Sensitivity, specificity, accuracy, positive and negative predictive values, P value and kappa agreement measures were calculated. We found a sensitivity of 47 and 100%, specificity of 95 and 75% and accuracy of 73 and 78.5%, respectively, for the medial and lateral meniscus. A sensitivity of 77.8%, specificity of 100% and accuracy of 94% was noted for the anterior cruciate ligament (ACL). We found good kappa agreements (0.43 and 0.45) for both menisci and excellent agreement (0.84) for the ACL. MRI shows high accuracy and should be used as the primary diagnostic tool for selection of candidates for arthroscopy. Level of evidence: 4. PMID:18506445

  3. Accuracies of breeding values for dry matter intake using nongenotyped animals and predictor traits in different lactations.

    PubMed

    Manzanilla-Pech, C I V; Veerkamp, R F; de Haas, Y; Calus, M P L; Ten Napel, J

    2017-11-01

    accuracies in comparison when only lactation 1 was included. Finally, no benefit was obtained by adding information on predictor traits to the reference population when DMI was already included. However, in the absence of DMI records, having records on FPCM and LW from different lactations is a good way to obtain EBV with a relatively good accuracy. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  4. Investigation on the Accuracy of Superposition Predictions of Film Cooling Effectiveness

    NASA Astrophysics Data System (ADS)

    Meng, Tong; Zhu, Hui-ren; Liu, Cun-liang; Wei, Jian-sheng

    2018-05-01

    Film cooling effectiveness on flat plates with double rows of holes has been studied experimentally and numerically in this paper. This configuration is widely used to simulate the multi-row film cooling on turbine vane. Film cooling effectiveness of double rows of holes and each single row was used to study the accuracy of superposition predictions. Method of stable infrared measurement technique was used to measure the surface temperature on the flat plate. This paper analyzed the factors that affect the film cooling effectiveness including hole shape, hole arrangement, row-to-row spacing and blowing ratio. Numerical simulations were performed to analyze the flow structure and film cooling mechanisms between each film cooling row. Results show that the blowing ratio within the range of 0.5 to 2 has a significant influence on the accuracy of superposition predictions. At low blowing ratios, results obtained by superposition method agree well with the experimental data. While at high blowing ratios, the accuracy of superposition prediction decreases. Another significant factor is hole arrangement. Results obtained by superposition prediction are nearly the same as experimental values of staggered arrangement structures. For in-line configurations, the superposition values of film cooling effectiveness are much higher than experimental data. For different hole shapes, the accuracy of superposition predictions on converging-expanding holes is better than cylinder holes and compound angle holes. For two different hole spacing structures in this paper, predictions show good agreement with the experiment results.

  5. 40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., measurement accuracy, and cut-off. 53.53 Section 53.53 Protection of Environment ENVIRONMENTAL PROTECTION..., measurement accuracy, and cut-off. (a) Overview. This test procedure is designed to evaluate a candidate... measurement accuracy, coefficient of variability measurement accuracy, and the flow rate cut-off function. The...

  6. Good Education, the Good Teacher, and a Practical Art of Living a Good Life: A Catholic Perspective

    ERIC Educational Resources Information Center

    Hermans, Chris

    2017-01-01

    What is good education? We value education for reasons connected to the good provided by education in society. This good is connected to be the pedagogical aim of education. This article distinguishes five criteria for good education based on the concept of "Bildung". Next, these five criteria are used to develop the idea of the good…

  7. What Makes a Good Student? How Emotions, Self-Regulated Learning, and Motivation Contribute to Academic Achievement

    ERIC Educational Resources Information Center

    Mega, Carolina; Ronconi, Lucia; De Beni, Rossana

    2014-01-01

    The authors propose a theoretical model linking emotions, self-regulated learning, and motivation to academic achievement. This model was tested with 5,805 undergraduate students. They completed the Self-Regulated Learning, Emotions, and Motivation Computerized Battery (LEM-B) composed of 3 self-report questionnaires: the Self-Regulated Learning…

  8. Prognostic accuracy of five simple scales in childhood bacterial meningitis.

    PubMed

    Pelkonen, Tuula; Roine, Irmeli; Monteiro, Lurdes; Cruzeiro, Manuel Leite; Pitkäranta, Anne; Kataja, Matti; Peltola, Heikki

    2012-08-01

    In childhood acute bacterial meningitis, the level of consciousness, measured with the Glasgow coma scale (GCS) or the Blantyre coma scale (BCS), is the most important predictor of outcome. The Herson-Todd scale (HTS) was developed for Haemophilus influenzae meningitis. Our objective was to identify prognostic factors, to form a simple scale, and to compare the predictive accuracy of these scales. Seven hundred and twenty-three children with bacterial meningitis in Luanda were scored by GCS, BCS, and HTS. The simple Luanda scale (SLS), based on our entire database, comprised domestic electricity, days of illness, convulsions, consciousness, and dyspnoea at presentation. The Bayesian Luanda scale (BLS) added blood glucose concentration. The accuracy of the 5 scales was determined for 491 children without an underlying condition, against the outcomes of death, severe neurological sequelae or death, or a poor outcome (severe neurological sequelae, death, or deafness), at hospital discharge. The highest accuracy was achieved with the BLS, whose area under the curve (AUC) for death was 0.83, for severe neurological sequelae or death was 0.84, and for poor outcome was 0.82. Overall, the AUCs for SLS were ≥0.79, for GCS were ≥0.76, for BCS were ≥0.74, and for HTS were ≥0.68. Adding laboratory parameters to a simple scoring system, such as the SLS, improves the prognostic accuracy only little in bacterial meningitis.

  9. Is Early Ability Grouping Good for High-Achieving Students' Psychosocial Development? Effects of the Transition into Academically Selective Schools

    ERIC Educational Resources Information Center

    Becker, Michael; Neumann, Marko; Tetzner, Julia; Böse, Susanne; Knoppick, Henrike; Maaz, Kai; Baumert, Jürgen; Lehmann, Rainer

    2014-01-01

    The present study investigates school context effects on psychosocial characteristics (academic self-concept, peer relations, school satisfaction, and school anxiety) of high-achieving and gifted students. Students who did or did not make an early transition from elementary to secondary schools for high-achieving and gifted students in 5th grade…

  10. Diagnostic accuracy of routine blood examinations and CSF lactate level for post-neurosurgical bacterial meningitis.

    PubMed

    Zhang, Yang; Xiao, Xiong; Zhang, Junting; Gao, Zhixian; Ji, Nan; Zhang, Liwei

    2017-06-01

    To evaluate the diagnostic accuracy of routine blood examinations and Cerebrospinal Fluid (CSF) lactate level for Post-neurosurgical Bacterial Meningitis (PBM) at a large sample-size of post-neurosurgical patients. The diagnostic accuracies of routine blood examinations and CSF lactate level to distinguish between PAM and PBM were evaluated with the values of the Area Under the Curve of the Receiver Operating Characteristic (AUC -ROC ) by retrospectively analyzing the datasets of post-neurosurgical patients in the clinical information databases. The diagnostic accuracy of routine blood examinations was relatively low (AUC -ROC <0.7). The CSF lactate level achieved rather high diagnostic accuracy (AUC -ROC =0.891; CI 95%, 0.852-0.922). The variables of patient age, operation duration, surgical diagnosis and postoperative days (the interval days between the neurosurgery and examinations) were shown to affect the diagnostic accuracy of these examinations. The variables were integrated with routine blood examinations and CSF lactate level by Fisher discriminant analysis to improve their diagnostic accuracy. As a result, the diagnostic accuracy of blood examinations and CSF lactate level was significantly improved with an AUC -ROC value=0.760 (CI 95%, 0.737-0.782) and 0.921 (CI 95%, 0.887-0.948) respectively. The PBM diagnostic accuracy of routine blood examinations was relatively low, whereas the accuracy of CSF lactate level was high. Some variables that are involved in the incidence of PBM can also affect the diagnostic accuracy for PBM. Taking into account the effects of these variables significantly improves the diagnostic accuracies of routine blood examinations and CSF lactate level. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Good manufacturing practices for medicinal products for human use.

    PubMed

    Gouveia, Bruno G; Rijo, Patrícia; Gonçalo, Tânia S; Reis, Catarina P

    2015-01-01

    At international and national levels, there are public and private organizations, institutions and regulatory authorities, who work and cooperate between them and with Pharmaceutical Industry, in order to achieve a consensus of the guidelines and laws of the manufacturing of medicinal products for human use. This article includes an explanation of how operate and cooperate these participants, between them and expose the current regulations, following the line of European Community/European Economic Area, referencing, wherever appropriate, the practiced guidelines, outside of regulatory action of space mentioned. In this way, it is intended to achieve quality, security and effectiveness exceptional levels in the manufacturing of health products. Good Manufacturing Practice aim the promotion of the human health and consequently, to the improvement of quality of life. For achieve the proposed objectives, it is necessary to ensure the applicability of the presented concepts and show the benefits arising from this applicability.

  12. Good manufacturing practices for medicinal products for human use

    PubMed Central

    Gouveia, Bruno G.; Rijo, Patrícia; Gonçalo, Tânia S.; Reis, Catarina P.

    2015-01-01

    At international and national levels, there are public and private organizations, institutions and regulatory authorities, who work and cooperate between them and with Pharmaceutical Industry, in order to achieve a consensus of the guidelines and laws of the manufacturing of medicinal products for human use. This article includes an explanation of how operate and cooperate these participants, between them and expose the current regulations, following the line of European Community/European Economic Area, referencing, wherever appropriate, the practiced guidelines, outside of regulatory action of space mentioned. In this way, it is intended to achieve quality, security and effectiveness exceptional levels in the manufacturing of health products. Good Manufacturing Practice aim the promotion of the human health and consequently, to the improvement of quality of life. For achieve the proposed objectives, it is necessary to ensure the applicability of the presented concepts and show the benefits arising from this applicability. PMID:25883511

  13. Enhancing Visual Perception and Motor Accuracy among School Children through a Mindfulness and Compassion Program

    PubMed Central

    Tarrasch, Ricardo; Margalit-Shalom, Lilach; Berger, Rony

    2017-01-01

    The present study assessed the effects of the mindfulness/compassion cultivating program: “Call to Care-Israel” on the performance in visual perception (VP) and motor accuracy, as well as on anxiety levels and self-reported mindfulness among 4th and 5th grade students. One hundred and thirty-eight children participated in the program for 24 weekly sessions, while 78 children served as controls. Repeated measures ANOVA’s yielded significant interactions between time of measurement and group for VP, motor accuracy, reported mindfulness, and anxiety. Post hoc tests revealed significant improvements in the four aforementioned measures in the experimental group only. In addition, significant correlations were obtained between the improvement in motor accuracy and the reduction in anxiety and the increase in mindfulness. Since VP and motor accuracy are basic skills associated with quantifiable academic characteristics, such as reading and mathematical abilities, the results may suggest that mindfulness practice has the ability to improve academic achievements. PMID:28286492

  14. Challenges in developing e-government for good governance in North Sumatra

    NASA Astrophysics Data System (ADS)

    Siahaan, AY

    2017-01-01

    E-government as one form of public administration reform in Indonesia is increasingly related to the pursuance of good governance. This paper examines the relationship between of e-government and good governance by utilizing the case study design on the implementation of e-procurement in North Sumatra. It reveals centrality of local politics and business culture in understanding resistances of both local government officials and local business which creates loopholes’ for the practice of ‘bad governance’ in all phases of e-procurement in North Sumatra province. Data transparency does not equate and guarantee the realization of good governance. Public knowledge and understanding on government decision making processes and accountability (process and policy transparency) are central to achieve good governance through e-procurement. E-procurement system does not automatically change organizational and working culture of the implementers and suppliers. This paper provides insight to the attitude and the perception of private sector engage in e-procurement towards government in implementing e-government. Resistance, digital divide and local politics interrelatedly obstruct the realization of pursuing good governance through e-procurement.

  15. SU-F-T-479: Estimation of the Accuracy in Respiratory-Gated Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurosawa, T; Miyakawa, S; Sato, M

    Purpose: Irregular respiratory patterns affects dose outputs in respiratorygated radiotherapy and there is no commercially available quality assurance (QA) system for it. We designed and developed a patient specific QA system for respiratory-gated radiotherapy to estimate irradiated output. Methods: Our in-house QA system for gating was composed of a personal computer with the USB-FSIO electronic circuit connecting to the linear accelerator (ONCOR-K, Toshiba Medical Systems). The linac implements a respiratory gating system (AZ-733V, Anzai Medical). During the beam was on, 4.2 V square-wave pulses were continually sent to the system. Our system can receive and count the pulses. At first,more » our system and an oscilloscope were compared to check the performance of our system. Next, basic estimation models were generated when ionization-chamber measurements were performed in gating using regular sinusoidal wave patterns (2.0, 2.5, 4.0, 8.0, 15 sec/cycle). During gated irradiation with the regular patterns, the number of the pulses per one gating window was measured using our system. Correlation between the number of the pulses per one gating and dose per the gating window were assessed to generate the estimation model. Finally, two irregular respiratory patterns were created and the accuracy of the estimation was evaluated. Results: Compared to the oscilloscope, our system worked similarly. The basic models were generated with the accuracy within 0.1%. The results of the gated irradiations with two irregular respiratory patterns show good agreement within 0.4% estimation accuracy. Conclusion: Our developed system shows good estimation for even irregular respiration patterns. The system would be a useful tool to verify the output for respiratory-gated radiotherapy.« less

  16. Accuracy of the 15-item Geriatric Depression Scale (GDS-15) in a community-dwelling oldest-old sample: the Pietà Study.

    PubMed

    Dias, Filipi Leles da Costa; Teixeira, Antônio Lúcio; Guimarães, Henrique Cerqueira; Barbosa, Maira Tonidandel; Resende, Elisa de Paula França; Beato, Rogério Gomes; Carmona, Karoline Carvalho; Caramelli, Paulo

    2017-01-01

    Late-life depression (LLD) is common, but remains underdiagnosed. Validated screening tools for use with the oldest-old in clinical practice are still lacking, particularly in developing countries. To evaluate the accuracy of a screening tool for LLD in a community-dwelling oldest-old sample. We evaluated 457 community-dwelling elderly subjects, aged ≥75 years and without dementia, with the Geriatric Depression Scale (GDS-15). Depression diagnosis was established according to DSM-IV criteria following a structured psychiatric interview with the Mini International Neuropsychiatric Interview (MINI). Fifty-two individuals (11.4%) were diagnosed with major depression. The area under the receiver operating characteristic (ROC) curve was 0.908 (p<0.001). Using a cut-off score of 5/6 (not depressed/depressed), 84 (18.4%) subjects were considered depressed by the GDS-15 (kappa coefficient = 53.8%, p<0.001). The 4/5 cut-off point achieved the best combination of sensitivity (86.5%) and specificity (82.7%) (Youden's index = 0.692), with robust negative (0.9802) and reasonable positive predictive values (0.3819). GDS-15 showed good accuracy as a screening tool for major depression in this community-based sample of low-educated oldest-old individuals. Our findings support the use of the 4/5 cut-off score, which showed the best diagnostic capacity.

  17. Comparative Diagnostic Accuracy of the ACE-III, MIS, MMSE, MoCA, and RUDAS for Screening of Alzheimer Disease.

    PubMed

    Matías-Guiu, Jordi A; Valles-Salgado, María; Rognoni, Teresa; Hamre-Gil, Frank; Moreno-Ramos, Teresa; Matías-Guiu, Jorge

    2017-01-01

    Our aim was to evaluate and compare the diagnostic properties of 5 screening tests for the diagnosis of mild Alzheimer disease (AD). We conducted a prospective and cross-sectional study of 92 patients with mild AD and of 68 healthy controls from our Department of Neurology. The diagnostic properties of the following tests were compared: Mini-Mental State Examination (MMSE), Addenbrooke's Cognitive Examination III (ACE-III), Memory Impairment Screen (MIS), Montreal Cognitive Assessment (MoCA), and Rowland Universal Dementia Assessment Scale (RUDAS). All tests yielded high diagnostic accuracy, with the ACE-III achieving the best diagnostic properties. The area under the curve was 0.897 for the ACE-III, 0.889 for the RUDAS, 0.874 for the MMSE, 0.866 for the MIS, and 0.856 for the MoCA. The Mini-ACE score from the ACE-III showed the highest diagnostic capacity (area under the curve 0.939). Memory scores of the ACE-III and of the RUDAS showed a better diagnostic accuracy than those of the MMSE and of the MoCA. All tests, especially the ACE-III, conveyed a higher diagnostic accuracy in patients with full primary education than in the less educated group. Implementing normative data improved the diagnostic accuracy of the ACE-III but not that of the other tests. The ACE-III achieved the highest diagnostic accuracy. This better discrimination was more evident in the more educated group. © 2017 S. Karger AG, Basel.

  18. Evaluation of a community-based sex offender treatment program using a good lives model approach.

    PubMed

    Harkins, Leigh; Flak, Vanja E; Beech, Anthony R; Woodhams, Jessica

    2012-12-01

    In this study the authors assessed a Good Lives model (GLM) approach to sex offender treatment and compare it to a standard Relapse Prevention program. The comparisons examined (a) attrition rates, (b) treatment change in areas targeted in treatment and achievement of a posttreatment treated profile, and (c) views of offenders and facilitators. There were no differences in the attrition rates or the rates of treatment change between the two programs, indicating that they were equally effective at retaining participants and achieving change on areas targeted within treatment. Both facilitators and program participants reported the Good Lives approach module's impact in a positive, future-focused manner. In contrast, those who attended the Relapse Prevention module did not report their perceptions and motivations in a manner that was focused on the positives in their future as frequently as those who attended the module with the Good Lives model approach.

  19. The role of feedback and differences between good and poor decoders in a repeated word reading paradigm in first grade.

    PubMed

    van Gorp, Karly; Segers, Eliane; Verhoeven, Ludo

    2017-04-01

    The direct, retention, and transfer effects of repeated word and pseudoword reading were studied in a pretest, training, posttest, retention design. First graders (48 good readers, 47 poor readers) read 25 CVC words and 25 CVC pseudowords in ten repeated word reading sessions, preceded and followed by a transfer task with a different set of items. Two weeks after training, trained items were assessed again in a retention test. Participants either received phonics feedback, in which each word was spelled out and repeated; word feedback, in which each word was repeated; or no feedback. During the training, both good and poor readers improved in accuracy and speed. The increase in speed was stronger for poor readers than for good readers. The good readers demonstrated a stronger increase for pseudowords than for words. This increase in speed was most prominent in the first four sessions. Two weeks after training, the levels of accuracy and speed were retained. Furthermore, transfer effects on speed were found for pseudowords in both groups of readers. Good readers performed most accurately during the training when they received no feedback while poor readers performed most accurately during the training with the help of phonics feedback. However, feedback did not differentiate for reading speed or for effects after the training. The effects of repeated word reading were found to be stronger for poor readers than for good readers. Moreover, these effects were found to be stronger for pseudowords than for words. This indicates that repeated word reading can be seen as an important trigger for the improvement of decoding skills.

  20. Accuracy of genomic selection models in a large population of open-pollinated families in white spruce

    PubMed Central

    Beaulieu, J; Doerksen, T; Clément, S; MacKay, J; Bousquet, J

    2014-01-01

    Genomic selection (GS) is of interest in breeding because of its potential for predicting the genetic value of individuals and increasing genetic gains per unit of time. To date, very few studies have reported empirical results of GS potential in the context of large population sizes and long breeding cycles such as for boreal trees. In this study, we assessed the effectiveness of marker-aided selection in an undomesticated white spruce (Picea glauca (Moench) Voss) population of large effective size using a GS approach. A discovery population of 1694 trees representative of 214 open-pollinated families from 43 natural populations was phenotyped for 12 wood and growth traits and genotyped for 6385 single-nucleotide polymorphisms (SNPs) mined in 2660 gene sequences. GS models were built to predict estimated breeding values using all the available SNPs or SNP subsets of the largest absolute effects, and they were validated using various cross-validation schemes. The accuracy of genomic estimated breeding values (GEBVs) varied from 0.327 to 0.435 when the training and the validation data sets shared half-sibs that were on average 90% of the accuracies achieved through traditionally estimated breeding values. The trend was also the same for validation across sites. As expected, the accuracy of GEBVs obtained after cross-validation with individuals of unknown relatedness was lower with about half of the accuracy achieved when half-sibs were present. We showed that with the marker densities used in the current study, predictions with low to moderate accuracy could be obtained within a large undomesticated population of related individuals, potentially resulting in larger gains per unit of time with GS than with the traditional approach. PMID:24781808

  1. Kinematic Visual Biofeedback Improves Accuracy of Learning a Swallowing Maneuver and Accuracy of Clinician Cues During Training.

    PubMed

    Azola, Alba M; Sunday, Kirstyn L; Humbert, Ianessa A

    2017-02-01

    Submental surface electromyography (ssEMG) visual biofeedback is widely used to train swallowing maneuvers. This study compares the effect of ssEMG and videofluoroscopy (VF) visual biofeedback on hyo-laryngeal accuracy when training a swallowing maneuver. Furthermore, it examines the clinician's ability to provide accurate verbal cues during swallowing maneuver training. Thirty healthy adults performed the volitional laryngeal vestibule closure maneuver (vLVC), which involves swallowing and sustaining closure of the laryngeal vestibule for 2 s. The study included two stages: (1) first accurate demonstration of the vLVC maneuver, followed by (2) training-20 vLVC training swallows. Participants were randomized into three groups: (a) ssEMG biofeedback only, (b) VF biofeedback only, and (c) mixed biofeedback (VF for the first accurate demonstration achieving stage and ssEMG for the training stage). Participants' performances were verbally critiqued or reinforced in real time while both the clinician and participant were observing the assigned visual biofeedback. VF and ssEMG were continuously recorded for all participants. Results show that accuracy of both vLVC performance and clinician cues was greater with VF biofeedback than with either ssEMG or mixed biofeedback (p < 0.001). Using ssEMG for providing real-time biofeedback during training could lead to errors while learning and training a swallowing maneuver.

  2. Ontario multidetector computed tomographic coronary angiography study: field evaluation of diagnostic accuracy.

    PubMed

    Chow, Benjamin J W; Freeman, Michael R; Bowen, James M; Levin, Leslie; Hopkins, Robert B; Provost, Yves; Tarride, Jean-Eric; Dennie, Carole; Cohen, Eric A; Marcuzzi, Dan; Iwanochko, Robert; Moody, Alan R; Paul, Narinder; Parker, John D; O'Reilly, Daria J; Xie, Feng; Goeree, Ron

    2011-06-13

    Computed tomographic coronary angiography (CTCA) has gained clinical acceptance for the detection of obstructive coronary artery disease. Although single-center studies have demonstrated excellent accuracy, multicenter studies have yielded variable results. The true diagnostic accuracy of CTCA in the "real world" remains uncertain. We conducted a field evaluation comparing multidetector CTCA with invasive CA (ICA) to understand CTCA's diagnostic accuracy in a real-world setting. A multicenter cohort study of patients awaiting ICA was conducted between September 2006 and June 2009. All patients had either a low or an intermediate pretest probability for coronary artery disease and underwent CTCA and ICA within 10 days. The results of CTCA and ICA were interpreted visually by local expert observers who were blinded to all clinical data and imaging results. Using a patient-based analysis (diameter stenosis ≥50%) of 169 patients, the sensitivity, specificity, positive predictive value, and negative predictive value were 81.3% (95% confidence interval [CI], 71.0%-89.1%), 93.3% (95% CI, 85.9%-97.5%), 91.6% (95% CI, 82.5%-96.8%), and 84.7% (95% CI, 76.0%-91.2%), respectively; the area under receiver operating characteristic curve was 0.873. The diagnostic accuracy varied across centers (P < .001), with a sensitivity, specificity, positive predictive value, and negative predictive value ranging from 50.0% to 93.2%, 92.0% to 100%, 84.6% to 100%, and 42.9% to 94.7%, respectively. Compared with ICA, CTCA appears to have good accuracy; however, there was variability in diagnostic accuracy across centers. Factors affecting institutional variability need to be better understood before CTCA is universally adopted. Additional real-world evaluations are needed to fully understand the impact of CTCA on clinical care. clinicaltrials.gov Identifier: NCT00371891.

  3. An anthropomorphic abdominal phantom for deformable image registration accuracy validation in adaptive radiation therapy.

    PubMed

    Liao, Yuliang; Wang, Linjing; Xu, Xiangdong; Chen, Haibin; Chen, Jiawei; Zhang, Guoqian; Lei, Huaiyu; Wang, Ruihao; Zhang, Shuxu; Gu, Xuejun; Zhen, Xin; Zhou, Linghong

    2017-06-01

    To design and construct a three-dimensional (3D) anthropomorphic abdominal phantom for geometric accuracy and dose summation accuracy evaluations of deformable image registration (DIR) algorithms for adaptive radiation therapy (ART). Organ molds, including liver, kidney, spleen, stomach, vertebra, and two metastasis tumors, were 3D printed using contours from an ovarian cancer patient. The organ molds were molded with deformable gels made of different mixtures of polyvinyl chloride (PVC) and the softener dioctyl terephthalate. Gels with different densities were obtained by a polynomial fitting curve that described the relation between the Hounsfield unit (HU) and PVC-softener blending ratio. The rigid vertebras were constructed by molding of white cement and cellulose pulp. The final abdominal phantom was assembled by arranging all the fabricated organs inside a hollow dummy according to their anatomies, and sealed by deformable gel with averaged HU of muscle and fat. Fiducial landmarks were embedded inside the phantom for spatial accuracy and dose accumulation accuracy studies. Two channels were excavated to facilitate ionization chamber insertion for dosimetric measurements. Phantom properties such as deformable gel elasticity and HU stability were studied. The dosimetric measurement accuracy in the phantom was performed, and the DIR accuracies of three DIR algorithms available in the open source DIR toolkit-DIRART were also validated. The constructed deformable gel showed elastic behavior and was stable in HU values over times, proving to be a practical material for the deformable phantom. The constructed abdominal phantom consisted of realistic anatomies in terms of both anatomical shapes and densities when compared with its reference patient. The dosimetric measurements showed a good agreement with the calculated doses from the treatment planning system. Fiducial-based accuracy analysis conducted on the constructed phantom demonstrated the feasibility of

  4. Can Dissimilar Users Contribute to Accuracy and Diversity of Personalized Recommendation?

    NASA Astrophysics Data System (ADS)

    Zeng, Wei; Shang, Ming-Sheng; Zhang, Qian-Ming; Lü, Linyuan; Zhou, Tao

    Recommender systems are becoming a popular and important set of personalization techniques that assist individual users with navigating through the rapidly growing amount of information. A good recommender system should be able to not only find out the objects preferred by users, but also help users in discovering their personalized tastes. The former corresponds to high accuracy of the recommendation, while the latter to high diversity. A big challenge is to design an algorithm that provides both highly accurate and diverse recommendation. Traditional recommendation algorithms only take into account the contributions of similar users, thus, they tend to recommend popular items for users ignoring the diversity of recommendations. In this paper, we propose a recommendation algorithm by considering both the effects of similar and dissimilar users under the framework of collaborative filtering. Extensive analyses on three datasets, namely MovieLens, Netflix and Amazon, show that our method performs much better than the standard collaborative filtering algorithm for both accuracy and diversity.

  5. Narrative Skills, Gender, Culture, and Children's Long-Term Memory Accuracy of a Staged Event

    ERIC Educational Resources Information Center

    Klemfuss, J. Zoe; Wang, Qi

    2017-01-01

    This study examined the extent to which school-aged children's general narrative skills provide cognitive benefits for accurate remembering or enable good storytelling that undermines memory accuracy. European American and Chinese American 6-year-old boys and girls (N = 114) experienced a staged event in the laboratory and were asked to tell a…

  6. High accuracy position response calibration method for a micro-channel plate ion detector

    NASA Astrophysics Data System (ADS)

    Hong, R.; Leredde, A.; Bagdasarova, Y.; Fléchard, X.; García, A.; Müller, P.; Knecht, A.; Liénard, E.; Kossin, M.; Sternberg, M. G.; Swanson, H. E.; Zumwalt, D. W.

    2016-11-01

    We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an in situ calibration mask, an accuracy of 8 μm and a resolution of 85 μm (FWHM) have been achieved for MeV-scale α particles and ions with energies of ∼10 keV. At this level of accuracy, the difference between the MCP position responses to high-energy α particles and low-energy ions is significant. The improved performance of the MCP detector can find applications in many fields of AMO and nuclear physics. In our case, it helps reducing systematic uncertainties in a high-precision nuclear β-decay experiment.

  7. Design and preliminary accuracy studies of an MRI-guided transrectal prostate intervention system.

    PubMed

    Krieger, Axel; Csoma, Csaba; Iordachital, Iulian I; Guion, Peter; Singh, Anurag K; Fichtinger, Gabor; Whitcomb, Louis L

    2007-01-01

    This paper reports a novel system for magnetic resonance imaging (MRI) guided transrectal prostate interventions, such as needle biopsy, fiducial marker placement, and therapy delivery. The system utilizes a hybrid tracking method, comprised of passive fiducial tracking for initial registration and subsequent incremental motion measurement along the degrees of freedom using fiber-optical encoders and mechanical scales. Targeting accuracy of the system is evaluated in prostate phantom experiments. Achieved targeting accuracy and procedure times were found to compare favorably with existing systems using passive and active tracking methods. Moreover, the portable design of the system using only standard MRI image sequences and minimal custom scanner interfacing allows the system to be easily used on different MRI scanners.

  8. Cumulative detection probabilities and range accuracy of a pulsed Geiger-mode avalanche photodiode laser ranging system

    NASA Astrophysics Data System (ADS)

    Luo, Hanjun; Ouyang, Zhengbiao; Liu, Qiang; Chen, Zhiliang; Lu, Hualan

    2017-10-01

    Cumulative pulses detection with appropriate cumulative pulses number and threshold has the ability to improve the detection performance of the pulsed laser ranging system with GM-APD. In this paper, based on Poisson statistics and multi-pulses cumulative process, the cumulative detection probabilities and their influence factors are investigated. With the normalized probability distribution of each time bin, the theoretical model of the range accuracy and precision is established, and the factors limiting the range accuracy and precision are discussed. The results show that the cumulative pulses detection can produce higher target detection probability and lower false alarm probability. However, for a heavy noise level and extremely weak echo intensity, the false alarm suppression performance of the cumulative pulses detection deteriorates quickly. The range accuracy and precision is another important parameter evaluating the detection performance, the echo intensity and pulse width are main influence factors on the range accuracy and precision, and higher range accuracy and precision is acquired with stronger echo intensity and narrower echo pulse width, for 5-ns echo pulse width, when the echo intensity is larger than 10, the range accuracy and precision lower than 7.5 cm can be achieved.

  9. Accuracy of WAAS-Enabled GPS-RF Warning Signals When Crossing a Terrestrial Geofence

    PubMed Central

    Grayson, Lindsay M.; Keefe, Robert F.; Tinkham, Wade T.; Eitel, Jan U. H.; Saralecos, Jarred D.; Smith, Alistair M. S.; Zimbelman, Eloise G.

    2016-01-01

    Geofences are virtual boundaries based on geographic coordinates. When combined with global position system (GPS), or more generally global navigation satellite system (GNSS) transmitters, geofences provide a powerful tool for monitoring the location and movements of objects of interest through proximity alarms. However, the accuracy of geofence alarms in GNSS-radio frequency (GNSS-RF) transmitter receiver systems has not been tested. To achieve these goals, a cart with a GNSS-RF locator was run on a straight path in a balanced factorial experiment with three levels of cart speed, three angles of geofence intersection, three receiver distances from the track, and three replicates. Locator speed, receiver distance and geofence intersection angle all affected geofence alarm accuracy in an analysis of variance (p = 0.013, p = 2.58 × 10−8, and p = 0.0006, respectively), as did all treatment interactions (p < 0.0001). Slower locator speed, acute geofence intersection angle, and closest receiver distance were associated with reduced accuracy of geofence alerts. PMID:27322287

  10. Accuracy of WAAS-Enabled GPS-RF Warning Signals When Crossing a Terrestrial Geofence.

    PubMed

    Grayson, Lindsay M; Keefe, Robert F; Tinkham, Wade T; Eitel, Jan U H; Saralecos, Jarred D; Smith, Alistair M S; Zimbelman, Eloise G

    2016-06-18

    Geofences are virtual boundaries based on geographic coordinates. When combined with global position system (GPS), or more generally global navigation satellite system (GNSS) transmitters, geofences provide a powerful tool for monitoring the location and movements of objects of interest through proximity alarms. However, the accuracy of geofence alarms in GNSS-radio frequency (GNSS-RF) transmitter receiver systems has not been tested. To achieve these goals, a cart with a GNSS-RF locator was run on a straight path in a balanced factorial experiment with three levels of cart speed, three angles of geofence intersection, three receiver distances from the track, and three replicates. Locator speed, receiver distance and geofence intersection angle all affected geofence alarm accuracy in an analysis of variance (p = 0.013, p = 2.58 × 10(-8), and p = 0.0006, respectively), as did all treatment interactions (p < 0.0001). Slower locator speed, acute geofence intersection angle, and closest receiver distance were associated with reduced accuracy of geofence alerts.

  11. Dynamic Modeling Accuracy Dependence on Errors in Sensor Measurements, Mass Properties, and Aircraft Geometry

    NASA Technical Reports Server (NTRS)

    Grauer, Jared A.; Morelli, Eugene A.

    2013-01-01

    A nonlinear simulation of the NASA Generic Transport Model was used to investigate the effects of errors in sensor measurements, mass properties, and aircraft geometry on the accuracy of dynamic models identified from flight data. Measurements from a typical system identification maneuver were systematically and progressively deteriorated and then used to estimate stability and control derivatives within a Monte Carlo analysis. Based on the results, recommendations were provided for maximum allowable errors in sensor measurements, mass properties, and aircraft geometry to achieve desired levels of dynamic modeling accuracy. Results using other flight conditions, parameter estimation methods, and a full-scale F-16 nonlinear aircraft simulation were compared with these recommendations.

  12. Comparing position and orientation accuracy of different electromagnetic sensors for tracking during interventions.

    PubMed

    Nijkamp, Jasper; Schermers, Bram; Schmitz, Sander; de Jonge, Sofieke; Kuhlmann, Koert; van der Heijden, Ferdinand; Sonke, Jan-Jakob; Ruers, Theo

    2016-08-01

    To compare the position and orientation accuracy between using one 6-degree of freedom (DOF) electromagnetic (EM) sensor, or the position information of three 5DOF sensors within the scope of tumor tracking. The position accuracy of Northern Digital Inc Aurora 5DOF and 6DOF sensors was determined for a table-top field generator (TTFG) up to a distance of 52 cm. For each sensor 716 positions were measured for 10 s at 15 Hz. Orientation accuracy was determined for each of the orthogonal axis at the TTFG distances of 17, 27, 37 and 47 cm. For the 6DOF sensors, orientation was determined for sensors in-line with the orientation axis, and perpendicular. 5DOF orientation accuracy was determined for a theoretical 4 cm tumor. An optical tracking system was used as reference. Position RMSE and jitter were comparable between the sensors and increasing with distance. Jitter was within 0.1 cm SD within 45 cm distance to the TTFG. Position RMSE was approximately 0.1 cm up to 32 cm distance, increasing to 0.4 cm at 52 cm distance. Orientation accuracy of the 6DOF sensor was within 1[Formula: see text], except when the sensor was in-line with the rotation axis perpendicular to the TTFG plane (4[Formula: see text] errors at 47 cm). Orientation accuracy using 5DOF positions was within 1[Formula: see text] up to 37 cm and 2[Formula: see text] at 47 cm. The position and orientation accuracy of a 6DOF sensor was comparable with a sensor configuration consisting of three 5DOF sensors. To achieve tracking accuracy within 1 mm and 1[Formula: see text], the distance to the TTFG should be limited to approximately 30 cm.

  13. Do good actions inspire good actions in others?

    PubMed

    Capraro, Valerio; Marcelletti, Alessandra

    2014-12-12

    Actions such as sharing food and cooperating to reach a common goal have played a fundamental role in the evolution of human societies. Despite the importance of such good actions, little is known about if and how they can spread from person to person to person. For instance, does being recipient of an altruistic act increase your probability of being cooperative with a third party? We have conducted an experiment on Amazon Mechanical Turk to test this mechanism using economic games. We have measured willingness to be cooperative through a standard Prisoner's dilemma and willingness to act altruistically using a binary Dictator game. In the baseline treatments, the endowments needed to play were given by the experimenters, as usual; in the control treatments, they came from a good action made by someone else. Across four different comparisons and a total of 572 subjects, we have never found a significant increase of cooperation or altruism when the endowment came from a good action. We conclude that good actions do not necessarily inspire good actions in others. While this is consistent with the theoretical prediction, it challenges the majority of other experimental studies.

  14. Behavioral Patterns in Special Education. Good Teaching Practices.

    PubMed

    Rodríguez-Dorta, Manuela; Borges, África

    2017-01-01

    Providing quality education means to respond to the diversity in the classroom. The teacher is a key figure in responding to the various educational needs presented by students. Specifically, special education professionals are of great importance as they are the ones who lend their support to regular classroom teachers and offer specialized educational assistance to students who require it. Therefore, special education is different from what takes place in the regular classroom, demanding greater commitment by the teacher. There are certain behaviors, considered good teaching practices, which teachers have always been connected with to achieve good teaching and good learning. To ensure that these teachers are carrying out their educational work properly it is necessary to evaluate. This means having appropriate instruments. The Observational Protocol for Teaching Functions in Primary School and Special Education (PROFUNDO-EPE, v.3., in Spanish) allows to capture behaviors from these professionals and behavioral patterns that correspond to good teaching practices. This study evaluates the behavior of two special education teachers who work with students from different educational stages and educational needs. It reveals that the analyzed teachers adapt their behavior according the needs and characteristics of their students to the students responding more adequately to the needs presented by the students and showing good teaching practices. The patterns obtained indicate that they offer support, help and clear guidelines to perform the tasks. They motivate them toward learning by providing positive feedback and they check that students have properly assimilated the contents through questions or non-verbal supervision. Also, they provide a safe and reliable climate for learning.

  15. A cross-sectional study of mathematics achievement, estimation skills, and academic self-perception in students of varying ability.

    PubMed

    Montague, Marjorie; van Garderen, Delinda

    2003-01-01

    This study investigated students' mathematics achievement, estimation ability, use of estimation strategies, and academic self-perception. Students with learning disabilities (LD), average achievers, and intellectually gifted students (N = 135) in fourth, sixth, and eighth grade participated in the study. They were assessed to determine their mathematics achievement, ability to estimate discrete quantities, knowledge and use of estimation strategies, and perception of academic competence. The results indicated that the students with LD performed significantly lower than their peers on the math achievement measures, as expected, but viewed themselves to be as academically competent as the average achievers did. Students with LD and average achievers scored significantly lower than gifted students on all estimation measures, but they differed significantly from one another only on the estimation strategy use measure. Interestingly, even gifted students did not seem to have a well-developed understanding of estimation and, like the other students, did poorly on the first estimation measure. The accuracy of their estimates seemed to improve, however, when students were asked open-ended questions about the strategies they used to arrive at their estimates. Although students with LD did not differ from average achievers in their estimation accuracy, they used significantly fewer effective estimation strategies. Implications for instruction are discussed.

  16. Understanding dental CAD/CAM for restorations--accuracy from a mechanical engineering viewpoint.

    PubMed

    Tapie, Laurent; Lebon, Nicolas; Mawussi, Bernardin; Fron-Chabouis, Hélène; Duret, Francois; Attal, Jean-Pierre

    2015-01-01

    As is the case in the field of medicine, as well as in most areas of daily life, digital technology is increasingly being introduced into dental practice. Computer-aided design/ computer-aided manufacturing (CAD/CAM) solutions are available not only for chairside practice but also for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental practice can be considered as the handling of devices and software processing for the almost automatic design and creation of dental restorations. However, dentists who want to use dental CAD/CAM systems often do not have enough information to understand the variations offered by such technology practice. Knowledge of the random and systematic errors in accuracy with CAD/CAM systems can help to achieve successful restorations with this technology, and help with the purchasing of a CAD/CAM system that meets the clinical needs of restoration. This article provides a mechanical engineering viewpoint of the accuracy of CAD/ CAM systems, to help dentists understand the impact of this technology on restoration accuracy.

  17. Optical System Error Analysis and Calibration Method of High-Accuracy Star Trackers

    PubMed Central

    Sun, Ting; Xing, Fei; You, Zheng

    2013-01-01

    The star tracker is a high-accuracy attitude measurement device widely used in spacecraft. Its performance depends largely on the precision of the optical system parameters. Therefore, the analysis of the optical system parameter errors and a precise calibration model are crucial to the accuracy of the star tracker. Research in this field is relatively lacking a systematic and universal analysis up to now. This paper proposes in detail an approach for the synthetic error analysis of the star tracker, without the complicated theoretical derivation. This approach can determine the error propagation relationship of the star tracker, and can build intuitively and systematically an error model. The analysis results can be used as a foundation and a guide for the optical design, calibration, and compensation of the star tracker. A calibration experiment is designed and conducted. Excellent calibration results are achieved based on the calibration model. To summarize, the error analysis approach and the calibration method are proved to be adequate and precise, and could provide an important guarantee for the design, manufacture, and measurement of high-accuracy star trackers. PMID:23567527

  18. Assessment of Delivery Accuracy in an Operational-Like Environment

    NASA Technical Reports Server (NTRS)

    Sharma, Shivanjli; Wynnyk, Mitch

    2016-01-01

    In order to enable arrival management concepts and solutions in a Next Generation Air Transportation System (NextGen) environment, ground-based sequencing and scheduling functions were developed to support metering operations in the National Airspace System. These sequencing and scheduling tools are designed to assist air traffic controllers in developing an overall arrival strategy, from enroute down to the terminal area boundary. NASA developed a ground system concept and protoype capability called Terminal Sequencing and Spacing (TSAS) to extend metering operations into the terminal area to the runway. To demonstrate the use of these scheduling and spacing tools in an operational-like environment, the FAA, NASA, and MITRE conducted an Operational Integration Assessment (OIA) of a prototype TSAS system at the FAA's William J. Hughes Technical Center (WJHTC). This paper presents an analysis of the arrival management strategies utilized and delivery accuracy achieved during the OIA. The analysis demonstrates how en route preconditioning, in various forms, and schedule disruptions impact delivery accuracy. As the simulation spanned both enroute and terminal airspace, the use of Ground Interval Management - Spacing (GIM-S) enroute speed advisories was investigated. Delivery accuracy was measured as the difference between the Scheduled Time of Arrival (STA) and the Actual Time of Arrival (ATA). The delivery accuracy was computed across all runs conducted during the OIA, which included deviations from nominal operations which are known to commonly occur in real operations, such as schedule changes and missed approaches. Overall, 83% of all flights were delivered into the terminal airspace within +/- 30 seconds of their STA and 94% of flights were delivered within +/- 60 seconds. The meter fix delivery accuracy standard deviation was found to be between 36 and 55 seconds across all arrival procedures. The data also showed when schedule disruptions were excluded, the

  19. TH-A-9A-05: Initial Setup Accuracy Comparison Between Frame-Based and Frameless Stereotactic Radiosurgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tseng, T; Sheu, R; Todorov, B

    2014-06-15

    Purpose: To evaluate initial setup accuracy for stereotactic radiosurgery (SRS) between Brainlab frame-based and frameless immobilization system, also to discern the magnitude frameless system has on setup parameters. Methods: The correction shifts from the original setup were compared for total 157 SRS cranial treatments (69 frame-based vs. 88 frameless). All treatments were performed on a Novalis linac with ExacTrac positioning system. Localization box with isocenter overlay was used for initial setup and correction shift was determined by ExacTrac 6D auto-fusion to achieve submillimeter accuracy for treatment. For frameless treatments, mean time interval between simulation and treatment was 5.7 days (rangemore » 0–13). Pearson Chi-Square was used for univariate analysis. Results: The correctional radial shifts (mean±STD, median) for the frame and frameless system measured by ExacTrac were 1.2±1.2mm, 1.1mm and 3.1±3.3mm, 2.0mm, respectively. Treatments with frameless system had a radial shift >2mm more often than those with frames (51.1% vs. 2.9%; p<.0001). To achieve submillimeter accuracy, 85.5% frame-based treatments did not require shift and only 23.9% frameless treatment could succeed with initial setup. There was no statistical significant system offset observed in any direction for either system. For frameless treatments, those treated ≥ 3 days from simulation had statistically higher rates of radial shifts between 1–2mm and >2mm compared to patients treated in a shorter amount of time from simulation (34.3% and 56.7% vs. 28.6% and 33.3%, respectively; p=0.006). Conclusion: Although image-guided positioning system can also achieve submillimeter accuracy for frameless system, users should be cautious regarding the inherent uncertainty of its capability of immobilization. A proper quality assurance procedure for frameless mask manufacturing and a protocol for intra-fraction imaging verification will be crucial for frameless system. Time interval

  20. Making High Accuracy Null Depth Measurements for the LBTI Exozodi Survey

    NASA Technical Reports Server (NTRS)

    Mennesson, Bertrand; Defrere, Denis; Nowak, Matthias; Hinz, Philip; Millan-Gabet, Rafael; Absil, Oliver; Bailey, Vanessa; Bryden, Geoffrey; Danchi, William C.; Kennedy, Grant M.; hide

    2016-01-01

    The characterization of exozodiacal light emission is both important for the understanding of planetary systems evolution and for the preparation of future space missions aiming to characterize low mass planets in the habitable zone of nearby main sequence stars. The Large Binocular Telescope Interferometer (LBTI) exozodi survey aims at providing a ten-fold improvement over current state of the art, measuring dust emission levels down to a typical accuracy of 12 zodis per star, for a representative ensemble of 30+ high priority targets. Such measurements promise to yield a final accuracy of about 2 zodis on the median exozodi level of the targets sample. Reaching a 1 sigma measurement uncertainty of 12 zodis per star corresponds to measuring interferometric cancellation (null) levels, i.e visibilities at the few 100 ppm uncertainty level. We discuss here the challenges posed by making such high accuracy mid-infrared visibility measurements from the ground and present the methodology we developed for achieving current best levels of 500 ppm or so. We also discuss current limitations and plans for enhanced exozodi observations over the next few years at LBTI.

  1. Existing methods for improving the accuracy of digital-to-analog converters

    NASA Astrophysics Data System (ADS)

    Eielsen, Arnfinn A.; Fleming, Andrew J.

    2017-09-01

    The performance of digital-to-analog converters is principally limited by errors in the output voltage levels. Such errors are known as element mismatch and are quantified by the integral non-linearity. Element mismatch limits the achievable accuracy and resolution in high-precision applications as it causes gain and offset errors, as well as harmonic distortion. In this article, five existing methods for mitigating the effects of element mismatch are compared: physical level calibration, dynamic element matching, noise-shaping with digital calibration, large periodic high-frequency dithering, and large stochastic high-pass dithering. These methods are suitable for improving accuracy when using digital-to-analog converters that use multiple discrete output levels to reconstruct time-varying signals. The methods improve linearity and therefore reduce harmonic distortion and can be retrofitted to existing systems with minor hardware variations. The performance of each method is compared theoretically and confirmed by simulations and experiments. Experimental results demonstrate that three of the five methods provide significant improvements in the resolution and accuracy when applied to a general-purpose digital-to-analog converter. As such, these methods can directly improve performance in a wide range of applications including nanopositioning, metrology, and optics.

  2. Does clinical pretest probability influence image quality and diagnostic accuracy in dual-source coronary CT angiography?

    PubMed

    Thomas, Christoph; Brodoefel, Harald; Tsiflikas, Ilias; Bruckner, Friederike; Reimann, Anja; Ketelsen, Dominik; Drosch, Tanja; Claussen, Claus D; Kopp, Andreas; Heuschmid, Martin; Burgstahler, Christof

    2010-02-01

    To prospectively evaluate the influence of the clinical pretest probability assessed by the Morise score onto image quality and diagnostic accuracy in coronary dual-source computed tomography angiography (DSCTA). In 61 patients, DSCTA and invasive coronary angiography were performed. Subjective image quality and accuracy for stenosis detection (>50%) of DSCTA with invasive coronary angiography as gold standard were evaluated. The influence of pretest probability onto image quality and accuracy was assessed by logistic regression and chi-square testing. Correlations of image quality and accuracy with the Morise score were determined using linear regression. Thirty-eight patients were categorized into the high, 21 into the intermediate, and 2 into the low probability group. Accuracies for the detection of significant stenoses were 0.94, 0.97, and 1.00, respectively. Logistic regressions and chi-square tests showed statistically significant correlations between Morise score and image quality (P < .0001 and P < .001) and accuracy (P = .0049 and P = .027). Linear regression revealed a cutoff Morise score for a good image quality of 16 and a cutoff for a barely diagnostic image quality beyond the upper Morise scale. Pretest probability is a weak predictor of image quality and diagnostic accuracy in coronary DSCTA. A sufficient image quality for diagnostic images can be reached with all pretest probabilities. Therefore, coronary DSCTA might be suitable also for patients with a high pretest probability. Copyright 2010 AUR. Published by Elsevier Inc. All rights reserved.

  3. Consequences of splitting whole-genome sequencing effort over multiple breeds on imputation accuracy.

    PubMed

    Bouwman, Aniek C; Veerkamp, Roel F

    2014-10-03

    The aim of this study was to determine the consequences of splitting sequencing effort over multiple breeds for imputation accuracy from a high-density SNP chip towards whole-genome sequence. Such information would assist for instance numerical smaller cattle breeds, but also pig and chicken breeders, who have to choose wisely how to spend their sequencing efforts over all the breeds or lines they evaluate. Sequence data from cattle breeds was used, because there are currently relatively many individuals from several breeds sequenced within the 1,000 Bull Genomes project. The advantage of whole-genome sequence data is that it carries the causal mutations, but the question is whether it is possible to impute the causal variants accurately. This study therefore focussed on imputation accuracy of variants with low minor allele frequency and breed specific variants. Imputation accuracy was assessed for chromosome 1 and 29 as the correlation between observed and imputed genotypes. For chromosome 1, the average imputation accuracy was 0.70 with a reference population of 20 Holstein, and increased to 0.83 when the reference population was increased by including 3 other dairy breeds with 20 animals each. When the same amount of animals from the Holstein breed were added the accuracy improved to 0.88, while adding the 3 other breeds to the reference population of 80 Holstein improved the average imputation accuracy marginally to 0.89. For chromosome 29, the average imputation accuracy was lower. Some variants benefitted from the inclusion of other breeds in the reference population, initially determined by the MAF of the variant in each breed, but even Holstein specific variants did gain imputation accuracy from the multi-breed reference population. This study shows that splitting sequencing effort over multiple breeds and combining the reference populations is a good strategy for imputation from high-density SNP panels towards whole-genome sequence when reference

  4. Determining dynamical parameters of the Milky Way Galaxy based on high-accuracy radio astrometry

    NASA Astrophysics Data System (ADS)

    Honma, Mareki; Nagayama, Takumi; Sakai, Nobuyuki

    2015-08-01

    In this paper we evaluate how the dynamical structure of the Galaxy can be constrained by high-accuracy VLBI (Very Long Baseline Interferometry) astrometry such as VERA (VLBI Exploration of Radio Astrometry). We generate simulated samples of maser sources which follow the gas motion caused by a spiral or bar potential, with their distribution similar to those currently observed with VERA and VLBA (Very Long Baseline Array). We apply the Markov chain Monte Carlo analyses to the simulated sample sources to determine the dynamical parameter of the models. We show that one can successfully determine the initial model parameters if astrometric results are obtained for a few hundred sources with currently achieved astrometric accuracy. If astrometric data are available from 500 sources, the expected accuracy of R0 and Θ0 is ˜ 1% or higher, and parameters related to the spiral structure can be constrained by an error of 10% or with higher accuracy. We also show that the parameter determination accuracy is basically independent of the locations of resonances such as corotation and/or inner/outer Lindblad resonances. We also discuss the possibility of model selection based on the Bayesian information criterion (BIC), and demonstrate that BIC can be used to discriminate different dynamical models of the Galaxy.

  5. Heterogeneous multi-layered IF steel with simultaneous high strength and good ductility

    NASA Astrophysics Data System (ADS)

    Zhang, Ling; Jiang, Xiaojuan; Wang, Yuhui; Chen, Qiang; Chen, Zhen; Zhang, Yonghong; Huang, Tianlin; Wu, Guilin

    2017-07-01

    Multi-layered IF steel samples were designed and fabricated by hot compression followed by cold forging of an alternating stack of cold-rolled and annealed IF steel sheets, with an aim to improve the strength of the material without losing much ductility. A very good combination of strength and ductility was achieved by proper annealing after deformation. Microstructural analysis by electron back-scatter diffraction revealed that the good combination of strength and ductility is related to a characteristic hierarchical structure that is characterized by layered and lamella structures with different length scales.

  6. Reliability and accuracy analysis of a new semiautomatic radiographic measurement software in adult scoliosis.

    PubMed

    Aubin, Carl-Eric; Bellefleur, Christian; Joncas, Julie; de Lanauze, Dominic; Kadoury, Samuel; Blanke, Kathy; Parent, Stefan; Labelle, Hubert

    2011-05-20

    Radiographic software measurement analysis in adult scoliosis. To assess the accuracy as well as the intra- and interobserver reliability of measuring different indices on preoperative adult scoliosis radiographs using a novel measurement software that includes a calibration procedure and semiautomatic features to facilitate the measurement process. Scoliosis requires a careful radiographic evaluation to assess the deformity. Manual and computer radiographic process measures have been studied extensively to determine the reliability and reproducibility in adolescent idiopathic scoliosis. Most studies rely on comparing given measurements, which are repeated by the same user or by an expert user. A given measure with a small intra- or interobserver error might be deemed as good repeatability, but all measurements might not be truly accurate because the ground-truth value is often unknown. Thorough accuracy assessment of radiographic measures is necessary to assess scoliotic deformities, compare these measures at different stages or to permit valid multicenter studies. Thirty-four sets of adult scoliosis digital radiographs were measured two times by three independent observers using a novel radiographic measurement software that includes semiautomatic features to facilitate the measurement process. Twenty different measures taken from the Spinal Deformity Study Group radiographic measurement manual were performed on the coronal and sagittal images. Intra- and intermeasurer reliability for each measure was assessed. The accuracy of the measurement software was also assessed using a physical spine model in six different scoliotic configurations as a true reference. The majority of the measures demonstrated good to excellent intra- and intermeasurer reliability, except for sacral obliquity. The standard variation of all the measures was very small: ≤ 4.2° for Cobb angles, ≤ 4.2° for the kyphosis, ≤ 5.7° for the lordosis, ≤ 3.9° for the pelvic angles, and

  7. Accuracy improvement techniques in Precise Point Positioning method using multiple GNSS constellations

    NASA Astrophysics Data System (ADS)

    Vasileios Psychas, Dimitrios; Delikaraoglou, Demitris

    2016-04-01

    The future Global Navigation Satellite Systems (GNSS), including modernized GPS, GLONASS, Galileo and BeiDou, offer three or more signal carriers for civilian use and much more redundant observables. The additional frequencies can significantly improve the capabilities of the traditional geodetic techniques based on GPS signals at two frequencies, especially with regard to the availability, accuracy, interoperability and integrity of high-precision GNSS applications. Furthermore, highly redundant measurements can allow for robust simultaneous estimation of static or mobile user states including more parameters such as real-time tropospheric biases and more reliable ambiguity resolution estimates. This paper presents an investigation and analysis of accuracy improvement techniques in the Precise Point Positioning (PPP) method using signals from the fully operational (GPS and GLONASS), as well as the emerging (Galileo and BeiDou) GNSS systems. The main aim was to determine the improvement in both the positioning accuracy achieved and the time convergence it takes to achieve geodetic-level (10 cm or less) accuracy. To this end, freely available observation data from the recent Multi-GNSS Experiment (MGEX) of the International GNSS Service, as well as the open source program RTKLIB were used. Following a brief background of the PPP technique and the scope of MGEX, the paper outlines the various observational scenarios that were used in order to test various data processing aspects of PPP solutions with multi-frequency, multi-constellation GNSS systems. Results from the processing of multi-GNSS observation data from selected permanent MGEX stations are presented and useful conclusions and recommendations for further research are drawn. As shown, data fusion from GPS, GLONASS, Galileo and BeiDou systems is becoming increasingly significant nowadays resulting in a position accuracy increase (mostly in the less favorable East direction) and a large reduction of convergence

  8. Single-frequency receivers as master permanent stations in GNSS networks: precision and accuracy of the positioning in mixed networks

    NASA Astrophysics Data System (ADS)

    Dabove, Paolo; Manzino, Ambrogio Maria

    2015-04-01

    The use of GPS/GNSS instruments is a common practice in the world at both a commercial and academic research level. Since last ten years, Continuous Operating Reference Stations (CORSs) networks were born in order to achieve the possibility to extend a precise positioning more than 15 km far from the master station. In this context, the Geomatics Research Group of DIATI at the Politecnico di Torino has carried out several experiments in order to evaluate the achievable precision obtainable with different GNSS receivers (geodetic and mass-market) and antennas if a CORSs network is considered. This work starts from the research above described, in particular focusing the attention on the usefulness of single frequency permanent stations in order to thicken the existing CORSs, especially for monitoring purposes. Two different types of CORSs network are available today in Italy: the first one is the so called "regional network" and the second one is the "national network", where the mean inter-station distances are about 25/30 and 50/70 km respectively. These distances are useful for many applications (e.g. mobile mapping) if geodetic instruments are considered but become less useful if mass-market instruments are used or if the inter-station distance between master and rover increases. In this context, some innovative GNSS networks were developed and tested, analyzing the performance of rover's positioning in terms of quality, accuracy and reliability both in real-time and post-processing approach. The use of single frequency GNSS receivers leads to have some limits, especially due to a limited baseline length, the possibility to obtain a correct fixing of the phase ambiguity for the network and to fix the phase ambiguity correctly also for the rover. These factors play a crucial role in order to reach a positioning with a good level of accuracy (as centimetric o better) in a short time and with an high reliability. The goal of this work is to investigate about the

  9. Prospective memory mediated by interoceptive accuracy: a psychophysiological approach.

    PubMed

    Umeda, Satoshi; Tochizawa, Saiko; Shibata, Midori; Terasawa, Yuri

    2016-11-19

    Previous studies on prospective memory (PM), defined as memory for future intentions, suggest that psychological stress enhances successful PM retrieval. However, the mechanisms underlying this notion remain poorly understood. We hypothesized that PM retrieval is achieved through interaction with autonomic nervous activity, which is mediated by the individual accuracy of interoceptive awareness, as measured by the heartbeat detection task. In this study, the relationship between cardiac reactivity and retrieval of delayed intentions was evaluated using the event-based PM task. Participants were required to detect PM target letters while engaged in an ongoing 2-back working memory task. The results demonstrated that individuals with higher PM task performance had a greater increase in heart rate on PM target presentation. Also, higher interoceptive perceivers showed better PM task performance. This pattern was not observed for working memory task performance. These findings suggest that cardiac afferent signals enhance PM retrieval, which is mediated by individual levels of interoceptive accuracy.This article is part of the themed issue 'Interoception beyond homeostasis: affect, cognition and mental health'. © 2016 The Authors.

  10. Technical Excellence: A Requirement for Good Engineering

    NASA Technical Reports Server (NTRS)

    Gill, Paul S.; Vaughan, William W.

    2008-01-01

    Technical excellence is a requirement for good engineering. Technical excellence has many different ways of expressing itself within engineering. NASA has initiatives that address the enhancement of the Agency's technical excellence and thrust to maintain the associated high level of performance by the Agency on current programs/projects and as it moves into the Constellation Program and the return to the Moon with plans to visit Mars. This paper addresses some of the key initiatives associated with NASA's technical excellence thrust. Examples are provided to illustrate some results being achieved and plans to enhance these initiatives.

  11. Accuracy statistics in predicting Independent Activities of Daily Living (IADL) capacity with comprehensive and brief neuropsychological test batteries.

    PubMed

    Karzmark, Peter; Deutsch, Gayle K

    2018-01-01

    This investigation was designed to determine the predictive accuracy of a comprehensive neuropsychological and brief neuropsychological test battery with regard to the capacity to perform instrumental activities of daily living (IADLs). Accuracy statistics that included measures of sensitivity, specificity, positive and negative predicted power and positive likelihood ratio were calculated for both types of batteries. The sample was drawn from a general neurological group of adults (n = 117) that included a number of older participants (age >55; n = 38). Standardized neuropsychological assessments were administered to all participants and were comprised of the Halstead Reitan Battery and portions of the Wechsler Adult Intelligence Scale-III. A comprehensive test battery yielded a moderate increase over base-rate in predictive accuracy that generalized to older individuals. There was only limited support for using a brief battery, for although sensitivity was high, specificity was low. We found that a comprehensive neuropsychological test battery provided good classification accuracy for predicting IADL capacity.

  12. Influence of Student–Teacher and Parent–Teacher Relationships on Lower Achieving Readers’ Engagement and Achievement in the Primary Grades

    PubMed Central

    Hughes, Jan; Kwok, Oi-man

    2007-01-01

    Participants were 443 (52.6% male, 47.4% female) ethnically diverse, 1st-grade, lower achieving readers attending 1 of 3 school districts in Texas. Using latent variable structural equation modeling, the authors tested a theoretical model positing that (a) the quality of teachers’ relationships with students and their parents mediates the associations between children’s background characteristics and teacher-rated classroom engagement and that (b) child classroom engagement, in turn, mediates the associations between student–teacher and parent–teacher relatedness and child achievement the following year. The hypothesized model provided a good fit to the data. African American children and their parents, relative to Hispanic and Caucasian children and their parents, had less supportive relationships with teachers. These differences in relatedness may be implicated in African American children’s lower achievement trajectories in the early grades. Implications of these findings for teacher preparation are discussed. PMID:18084625

  13. The Impact of Pushed Output on Accuracy and Fluency of Iranian EFL Learners' Speaking

    ERIC Educational Resources Information Center

    Sadeghi Beniss, Aram Reza; Edalati Bazzaz, Vahid

    2014-01-01

    The current study attempted to establish baseline quantitative data on the impacts of pushed output on two components of speaking (i.e., accuracy and fluency). To achieve this purpose, 30 female EFL learners were selected from a whole population pool of 50 based on the standard test of IELTS interview and were randomly assigned into an…

  14. Medical records. Enhancing privacy, preserving the common good.

    PubMed

    Etzioni, A

    1999-01-01

    Personal medical information is now bought and sold on the open market. Companies use it to make hiring and firing decisions and to identify customers for new products. The justification for providing such access to medical information is that doing so benefits the public by securing public safety, controlling costs, and supporting medical research. And individuals have supposedly consented to it. But we can achieve the common goods while better protecting privacy by making institutional changes in the way information is maintained and protected.

  15. Variability of Diabetes Alert Dog Accuracy in a Real-World Setting

    PubMed Central

    Gonder-Frederick, Linda A.; Grabman, Jesse H.; Shepard, Jaclyn A.; Tripathi, Anand V.; Ducar, Dallas M.; McElgunn, Zachary R.

    2017-01-01

    Background: Diabetes alert dogs (DADs) are growing in popularity as an alternative method of glucose monitoring for individuals with type 1 diabetes (T1D). Only a few empirical studies have assessed DAD accuracy, with inconsistent results. The present study examined DAD accuracy and variability in performance in real-world conditions using a convenience sample of owner-report diaries. Method: Eighteen DAD owners (44.4% female; 77.8% youth) with T1D completed diaries of DAD alerts during the first year after placement. Diary entries included daily BG readings and DAD alerts. For each DAD, percentage hits (alert with BG ≤ 5.0 or ≥ 11.1 mmol/L; ≤90 or ≥200 mg/dl), percentage misses (no alert with BG out of range), and percentage false alarms (alert with BG in range) were computed. Sensitivity, specificity, positive likelihood ratio (PLR), and true positive rates were also calculated. Results: Overall comparison of DAD Hits to Misses yielded significantly more Hits for both low and high BG. Total sensitivity was 57.0%, with increased sensitivity to low BG (59.2%) compared to high BG (56.1%). Total specificity was 49.3% and PLR = 1.12. However, high variability in accuracy was observed across DADs, with low BG sensitivity ranging from 33% to 100%. Number of DADs achieving ≥ 60%, 65% and 70% true positive rates was 71%, 50% and 44%, respectively. Conclusions: DADs may be able to detect out-of-range BG, but variability across DADs is evident. Larger trials are needed to further assess DAD accuracy and to identify factors influencing the complexity of DAD accuracy in BG detection. PMID:28627305

  16. STTR Phase I: Low-Cost, High-Accuracy, Whole-Building Carbon Dioxide Monitoring for Demand Control Ventilation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hallstrom, Jason O.; Ni, Zheng Richard

    This STTR Phase I project assessed the feasibility of a new CO 2 sensing system optimized for low-cost, high-accuracy, whole-building monitoring for use in demand control ventilation. The focus was on the development of a wireless networking platform and associated firmware to provide signal conditioning and conversion, fault- and disruptiontolerant networking, and multi-hop routing at building scales to avoid wiring costs. Early exploration of a bridge (or “gateway”) to direct digital control services was also explored. Results of the project contributed to an improved understanding of a new electrochemical sensor for monitoring indoor CO 2 concentrations, as well as themore » electronics and networking infrastructure required to deploy those sensors at building scales. New knowledge was acquired concerning the sensor’s accuracy, environmental response, and failure modes, and the acquisition electronics required to achieve accuracy over a wide range of CO 2 concentrations. The project demonstrated that the new sensor offers repeatable correspondence with commercial optical sensors, with supporting electronics that offer gain accuracy within 0.5%, and acquisition accuracy within 1.5% across three orders of magnitude variation in generated current. Considering production, installation, and maintenance costs, the technology presents a foundation for achieving whole-building CO 2 sensing at a price point below $0.066 / sq-ft – meeting economic feasibility criteria established by the Department of Energy. The technology developed under this award addresses obstacles on the critical path to enabling whole-building CO 2 sensing and demand control ventilation in commercial retrofits, small commercial buildings, residential complexes, and other highpotential structures that have been slow to adopt these technologies. It presents an opportunity to significantly reduce energy use throughout the United States.« less

  17. Three Decades of Precision Orbit Determination Progress, Achievements, Future Challenges and its Vital Contribution to Oceanography and Climate Research

    NASA Technical Reports Server (NTRS)

    Luthcke, Scott; Rowlands, David; Lemoine, Frank; Zelensky, Nikita; Beckley, Brian; Klosko, Steve; Chinn, Doug

    2006-01-01

    Although satellite altimetry has been around for thirty years, the last fifteen beginning with the launch of TOPEX/Poseidon (TP) have yielded an abundance of significant results including: monitoring of ENS0 events, detection of internal tides, determination of accurate global tides, unambiguous delineation of Rossby waves and their propagation characteristics, accurate determination of geostrophic currents, and a multi-decadal time series of mean sea level trend and dynamic ocean topography variability. While the high level of accuracy being achieved is a result of both instrument maturity and the quality of models and correction algorithms applied to the data, improving the quality of the Climate Data Records produced from altimetry is highly dependent on concurrent progress being made in fields such as orbit determination. The precision orbits form the reference frame from which the radar altimeter observations are made. Therefore, the accuracy of the altimetric mapping is limited to a great extent by the accuracy to which a satellite orbit can be computed. The TP mission represents the first time that the radial component of an altimeter orbit was routinely computed with an accuracy of 2-cm. Recently it has been demonstrated that it is possible to compute the radial component of Jason orbits with an accuracy of better than 1-cm. Additionally, still further improvements in TP orbits are being achieved with new techniques and algorithms largely developed from combined Jason and TP data analysis. While these recent POD achievements are impressive, the new accuracies are now revealing subtle systematic orbit error that manifest as both intra and inter annual ocean topography errors. Additionally the construction of inter-decadal time series of climate data records requires the removal of systematic differences across multiple missions. Current and future efforts must focus on the understanding and reduction of these errors in order to generate a complete and

  18. A method for assessing the accuracy of surgical technique in the correction of astigmatism.

    PubMed

    Kaye, S B; Campbell, S H; Davey, K; Patterson, A

    1992-12-01

    Surgical results can be assessed as a function of what was aimed for, what was done, and what was achieved. One of the aims of refractive surgery is to reduce astigmatism; the smaller the postoperative astigmatism the better the result. Determination of what was done--that is, the surgical effect, can be calculated from the preoperative and postoperative astigmatism. A simplified formulation is described which facilitates the calculation (magnitude and direction) of this surgical effect. In addition, an expression for surgical accuracy is described, as a function of what was aimed for and what was achieved.

  19. Accuracy of torque-limiting devices: A comparative evaluation.

    PubMed

    Albayrak, Haydar; Gumus, Hasan Onder; Tursun, Funda; Kocaagaoglu, Hasan Huseyin; Kilinc, Halil Ibrahim

    2017-01-01

    To prevent the loosening of implant screws, clinicians should be aware of the output torque values needed to achieve the desired preload. Accurate torque-control devices are crucial in this regard; however, little information is currently available comparing the accuracy of mechanical with that of electronic torque-control devices. The purpose of this in vitro study was to identify and compare the accuracy of different types of torque-control devices. Devices from 5 different dental implant manufacturers were evaluated, including 2 spring-type (Straumann, Implance) mechanical devices (MTLD), 2 friction-type (Biohorizons, Dyna) MTLDs, and 1 (Megagen) electronic torque-control device (ETLD). For each manufacturer, 5 devices were tested 5 times with a digital torque tester, and the average for each device was calculated and recorded. The percentage of absolute deviations from the target torque values (PERDEV) were calculated and compared by using 1-way ANOVA. A 1-sample t test was used to evaluate the ability of each device to achieve its target torque value within a 95% confidence interval for the true population mean of measured values (α=.05 for all statistical analyses). One-way ANOVAs revealed statistically significant differences among torque-control devices (P<.001). ETLD showed higher PERDEVs (28.33 ±9.53) than MTLDs (P<.05), whereas PERDEVS of friction-type (7.56 ±3.64) and spring-type (10.85 ±4.11) MTLDs did not differ significantly. In addition, devices produced by Megagen had a significantly higher (P<.05) PERDEV (28.33 ±9.53) other devices, whereas no differences were found in devices manufactured by Biohorizons (7.31 ±5.34), Dyna (7.82 ±1.08), Implance (8.43 ±4.77), and Straumann (13.26 ±0.79). However, 1-sample t tests showed none of the torque-control devices evaluated in this study were capable of achieving their target torque values (P<.05). Within the limitations of this in vitro study, MTLDs were shown to be significantly more accurate

  20. Improving the sensitivity and accuracy of gamma activation analysis for the rapid determination of gold in mineral ores.

    PubMed

    Tickner, James; Ganly, Brianna; Lovric, Bojan; O'Dwyer, Joel

    2017-04-01

    Mining companies rely on chemical analysis methods to determine concentrations of gold in mineral ore samples. As gold is often mined commercially at concentrations around 1 part-per-million, it is necessary for any analysis method to provide good sensitivity as well as high absolute accuracy. We describe work to improve both the sensitivity and accuracy of the gamma activation analysis (GAA) method for gold. We present analysis results for several suites of ore samples and discuss the design of a GAA facility designed to replace conventional chemical assay in industrial applications. Copyright © 2017. Published by Elsevier Ltd.

  1. [Assessment of precision and accuracy of digital surface photogrammetry with the DSP 400 system].

    PubMed

    Krimmel, M; Kluba, S; Dietz, K; Reinert, S

    2005-03-01

    The objective of the present study was to evaluate the precision and accuracy of facial anthropometric measurements obtained through digital 3-D surface photogrammetry with the DSP 400 system in comparison to traditional 2-D photogrammetry. Fifty plaster casts of cleft infants were imaged and 21 standard anthropometric measurements were obtained. For precision assessment the measurements were performed twice in a subsample. Accuracy was determined by comparison of direct measurements and indirect 2-D and 3-D image measurements. Precision of digital surface photogrammetry was almost as good as direct anthropometry and clearly better than 2-D photogrammetry. Measurements derived from 3-D images showed better congruence to direct measurements than from 2-D photos. Digital surface photogrammetry with the DSP 400 system is sufficiently precise and accurate for craniofacial anthropometric examinations.

  2. Toward Quantitative Small Animal Pinhole SPECT: Assessment of Quantitation Accuracy Prior to Image Compensations

    PubMed Central

    Chen, Chia-Lin; Wang, Yuchuan; Lee, Jason J. S.; Tsui, Benjamin M. W.

    2011-01-01

    Purpose We assessed the quantitation accuracy of small animal pinhole single photon emission computed tomography (SPECT) under the current preclinical settings, where image compensations are not routinely applied. Procedures The effects of several common image-degrading factors and imaging parameters on quantitation accuracy were evaluated using Monte-Carlo simulation methods. Typical preclinical imaging configurations were modeled, and quantitative analyses were performed based on image reconstructions without compensating for attenuation, scatter, and limited system resolution. Results Using mouse-sized phantom studies as examples, attenuation effects alone degraded quantitation accuracy by up to −18% (Tc-99m or In-111) or −41% (I-125). The inclusion of scatter effects changed the above numbers to −12% (Tc-99m or In-111) and −21% (I-125), respectively, indicating the significance of scatter in quantitative I-125 imaging. Region-of-interest (ROI) definitions have greater impacts on regional quantitation accuracy for small sphere sources as compared to attenuation and scatter effects. For the same ROI, SPECT acquisitions using pinhole apertures of different sizes could significantly affect the outcome, whereas the use of different radii-of-rotation yielded negligible differences in quantitation accuracy for the imaging configurations simulated. Conclusions We have systematically quantified the influence of several factors affecting the quantitation accuracy of small animal pinhole SPECT. In order to consistently achieve accurate quantitation within 5% of the truth, comprehensive image compensation methods are needed. PMID:19048346

  3. Ultrasound indoor positioning system based on a low-power wireless sensor network providing sub-centimeter accuracy.

    PubMed

    Medina, Carlos; Segura, José Carlos; De la Torre, Ángel

    2013-03-13

    This paper describes the TELIAMADE system, a new indoor positioning system based on time-of-flight (TOF) of ultrasonic signal to estimate the distance between a receiver node and a transmitter node. TELIAMADE system consists of a set of wireless nodes equipped with a radio module for communication and a module for the transmission and reception of ultrasound. The access to the ultrasonic channel is managed by applying a synchronization algorithm based on a time-division multiplexing (TDMA) scheme. The ultrasonic signal is transmitted using a carrier frequency of 40 kHz and the TOF measurement is estimated by applying a quadrature detector to the signal obtained at the A/D converter output. Low sampling frequencies of 17.78 kHz or even 12.31 kHz are possible using quadrature sampling in order to optimize memory requirements and to reduce the computational cost in signal processing. The distance is calculated from the TOF taking into account the speed of sound. An excellent accuracy in the estimation of the TOF is achieved using parabolic interpolation to detect of maximum of the signal envelope at the matched filter output. The signal phase information is also used for enhancing the TOF measurement accuracy. Experimental results show a root mean square error (rmse) less than 2 mm and a standard deviation less than 0.3 mm for pseudorange measurements in the range of distances between 2 and 6 m. The system location accuracy is also evaluated by applying multilateration. A sub-centimeter location accuracy is achieved with an average rmse of 9.6 mm.

  4. Accuracy of magnetic resonance based susceptibility measurements

    NASA Astrophysics Data System (ADS)

    Erdevig, Hannah E.; Russek, Stephen E.; Carnicka, Slavka; Stupic, Karl F.; Keenan, Kathryn E.

    2017-05-01

    Magnetic Resonance Imaging (MRI) is increasingly used to map the magnetic susceptibility of tissue to identify cerebral microbleeds associated with traumatic brain injury and pathological iron deposits associated with neurodegenerative diseases such as Parkinson's and Alzheimer's disease. Accurate measurements of susceptibility are important for determining oxygen and iron content in blood vessels and brain tissue for use in noninvasive clinical diagnosis and treatment assessments. Induced magnetic fields with amplitude on the order of 100 nT, can be detected using MRI phase images. The induced field distributions can then be inverted to obtain quantitative susceptibility maps. The focus of this research was to determine the accuracy of MRI-based susceptibility measurements using simple phantom geometries and to compare the susceptibility measurements with magnetometry measurements where SI-traceable standards are available. The susceptibilities of paramagnetic salt solutions in cylindrical containers were measured as a function of orientation relative to the static MRI field. The observed induced fields as a function of orientation of the cylinder were in good agreement with simple models. The MRI susceptibility measurements were compared with SQUID magnetometry using NIST-traceable standards. MRI can accurately measure relative magnetic susceptibilities while SQUID magnetometry measures absolute magnetic susceptibility. Given the accuracy of moment measurements of tissue mimicking samples, and the need to look at small differences in tissue properties, the use of existing NIST standard reference materials to calibrate MRI reference structures is problematic and better reference materials are required.

  5. Behavioral Patterns in Special Education. Good Teaching Practices

    PubMed Central

    Rodríguez-Dorta, Manuela; Borges, África

    2017-01-01

    Providing quality education means to respond to the diversity in the classroom. The teacher is a key figure in responding to the various educational needs presented by students. Specifically, special education professionals are of great importance as they are the ones who lend their support to regular classroom teachers and offer specialized educational assistance to students who require it. Therefore, special education is different from what takes place in the regular classroom, demanding greater commitment by the teacher. There are certain behaviors, considered good teaching practices, which teachers have always been connected with to achieve good teaching and good learning. To ensure that these teachers are carrying out their educational work properly it is necessary to evaluate. This means having appropriate instruments. The Observational Protocol for Teaching Functions in Primary School and Special Education (PROFUNDO-EPE, v.3., in Spanish) allows to capture behaviors from these professionals and behavioral patterns that correspond to good teaching practices. This study evaluates the behavior of two special education teachers who work with students from different educational stages and educational needs. It reveals that the analyzed teachers adapt their behavior according the needs and characteristics of their students to the students responding more adequately to the needs presented by the students and showing good teaching practices. The patterns obtained indicate that they offer support, help and clear guidelines to perform the tasks. They motivate them toward learning by providing positive feedback and they check that students have properly assimilated the contents through questions or non-verbal supervision. Also, they provide a safe and reliable climate for learning. PMID:28512437

  6. [Study on high accuracy detection of multi-component gas in oil-immerse power transformer].

    PubMed

    Fan, Jie; Chen, Xiao; Huang, Qi-Feng; Zhou, Yu; Chen, Gang

    2013-12-01

    In order to solve the problem of low accuracy and mutual interference in multi-component gas detection, a kind of multi-component gas detection network with high accuracy was designed. A semiconductor laser with narrow bandwidth was utilized as light source and a novel long-path gas cell was also used in this system. By taking the single sine signal to modulate the spectrum of laser and using space division multiplexing (SDM) and time division multiplexing (TDM) technique, the detection of multi-component gas was achieved. The experiments indicate that the linearity relevance coefficient is 0. 99 and the measurement relative error is less than 4%. The system dynamic response time is less than 15 s, by filling a volume of multi-component gas into the gas cell gradually. The system has advantages of high accuracy and quick response, which can be used in the fault gas on-line monitoring for power transformers in real time.

  7. [Precision and accuracy of "a pocket" pulse oximeter in Mexico City].

    PubMed

    Torre-Bouscoulet, Luis; Chávez-Plascencia, Elizabeth; Vázquez-García, Juan Carlos; Pérez-Padilla, Rogelio

    2006-01-01

    Pulse oximeters are frequently used in the clinical practice and we must known their precision and accuracy. The objective was to evaluate the precision and accuracy of a "pocket" pulse oximeter at an altitude of 2,240 m above sea level. We tested miniature pulse oximeters (Onyx 9,500, Nonin Finger Pulse Oximeter) in 96 patients sent to the pulmonary laboratory for an arterial blood sample. Patients were tested with 5 pulse oximeters placed in each of the fingers of the hand oposite to that used for the arterial puncture. The gold standard was the oxygen saturation of the arterial blood sample. Blood samples had SaO2 of 87.2 +/- 11.0 (between 42.2 and 97.9%). Pulse oximeters had a mean error of 0.28 +/- 3.1%. SaO2 = (1.204 x SpO2) - 17.45966 (r = 0.92, p < 0.0001). Intraclass correlation coefficient between each of five pulse oximeters against the arterial blood standard ranged between 0.87 and 0.99. HbCO (2.4 +/- 0.6) did not affect the accuracy. The miniature oximeter Nonin is precise and accurate at 2,240 m of altitude. The observed levels of HbCO did not affect the performance of the equipment. The oximeter good performance, small size and low cost enhances its clinical usefulness.

  8. High Accuracy 3D Processing of Satellite Imagery

    NASA Technical Reports Server (NTRS)

    Gruen, A.; Zhang, L.; Kocaman, S.

    2007-01-01

    Automatic DSM/DTM generation reproduces not only general features, but also detailed features of the terrain relief. Height accuracy of around 1 pixel in cooperative terrain. RMSE values of 1.3-1.5 m (1.0-2.0 pixels) for IKONOS and RMSE values of 2.9-4.6 m (0.5-1.0 pixels) for SPOT5 HRS. For 3D city modeling, the manual and semi-automatic feature extraction capability of SAT-PP provides a good basis. The tools of SAT-PP allowed the stereo-measurements of points on the roofs in order to generate a 3D city model with CCM The results show that building models with main roof structures can be successfully extracted by HRSI. As expected, with Quickbird more details are visible.

  9. Trait Perception Accuracy and Acquaintance Within Groups: Tracking Accuracy Development.

    PubMed

    Brown, Jill A; Bernieri, Frank

    2017-05-01

    Previous work on trait perception has evaluated accuracy at discrete stages of relationships (e.g., strangers, best friends). A relatively limited body of literature has investigated changes in accuracy as acquaintance within a dyad or group increases. Small groups of initially unacquainted individuals spent more than 30 hr participating in a wide range of activities designed to represent common interpersonal contexts (e.g., eating, traveling). We calculated how accurately each participant judged others in their group on the big five traits across three distinct points within the acquaintance process: zero acquaintance, after a getting-to-know-you conversation, and after 10 weeks of interaction and activity. Judgments of all five traits exhibited accuracy above chance levels after 10 weeks. An examination of the trait rating stability revealed that much of the revision in judgments occurred not over the course of the 10-week relationship as suspected, but between zero acquaintance and the getting-to-know-you conversation.

  10. Cavity ring-down spectroscopy of Doppler-broadened absorption line with sub-MHz absolute frequency accuracy.

    PubMed

    Cheng, C-F; Sun, Y R; Pan, H; Lu, Y; Li, X-F; Wang, J; Liu, A-W; Hu, S-M

    2012-04-23

    A continuous-wave cavity ring-down spectrometer has been built for precise determination of absolute frequencies of Doppler-broadened absorption lines. Using a thermo-stabilized Fabry-Pérot interferometer and Rb frequency references at the 780 nm and 795 nm, 0.1 - 0.6 MHz absolute frequency accuracy has been achieved in the 775-800 nm region. A water absorption line at 12579 cm(-1) is studied to test the performance of the spectrometer. The line position at zero-pressure limit is determined with an uncertainty of 0.3 MHz (relative accuracy of 0.8 × 10(-9)). © 2012 Optical Society of America

  11. Correlates of midlife career achievement among women physicians.

    PubMed

    Graves, P L; Thomas, C B

    1985-08-09

    In the context of a longitudinal study, we explored factors contributing to midlife career achievement among 108 women physicians. Three groups were formed, based on medical specialty, specialty board certification, and professorial appointment. Using analysis of variance procedures, the career groups were compared on measures obtained during medical school and on marital status, family size, and three health measures in midlife. Of the youthful measures, academic standing, father's socioeconomic status, and early family (specifically father-daughter) relationships were found to be associated with midlife achievement. Furthermore, a clear association was observed between success and good health in midlife. Married women formed the majority in all groups; no differences in family size were found. We conclude that career achievement among women physicians is influenced less by marriage and family size than by motivational and personality factors shaped in early life.

  12. Good quantification practices of flavours and fragrances by mass spectrometry.

    PubMed

    Begnaud, Frédéric; Chaintreau, Alain

    2016-10-28

    Over the past 15 years, chromatographic techniques with mass spectrometric detection have been increasingly used to monitor the rapidly expanded list of regulated flavour and fragrance ingredients. This trend entails a need for good quantification practices suitable for complex media, especially for multi-analytes. In this article, we present experimental precautions needed to perform the analyses and ways to process the data according to the most recent approaches. This notably includes the identification of analytes during their quantification and method validation, when applied to real matrices, based on accuracy profiles. A brief survey of application studies based on such practices is given.This article is part of the themed issue 'Quantitative mass spectrometry'. © 2016 The Authors.

  13. The Social Accuracy Model of Interpersonal Perception: Assessing Individual Differences in Perceptive and Expressive Accuracy

    ERIC Educational Resources Information Center

    Biesanz, Jeremy C.

    2010-01-01

    The social accuracy model of interpersonal perception (SAM) is a componential model that estimates perceiver and target effects of different components of accuracy across traits simultaneously. For instance, Jane may be generally accurate in her perceptions of others and thus high in "perceptive accuracy"--the extent to which a particular…

  14. Speed-Accuracy Response Models: Scoring Rules Based on Response Time and Accuracy

    ERIC Educational Resources Information Center

    Maris, Gunter; van der Maas, Han

    2012-01-01

    Starting from an explicit scoring rule for time limit tasks incorporating both response time and accuracy, and a definite trade-off between speed and accuracy, a response model is derived. Since the scoring rule is interpreted as a sufficient statistic, the model belongs to the exponential family. The various marginal and conditional distributions…

  15. Cognitive Predictors of Achievement Growth in Mathematics: A Five Year Longitudinal Study

    PubMed Central

    Geary, David C.

    2011-01-01

    The study's goal was to identify the beginning of first grade quantitative competencies that predict mathematics achievement start point and growth through fifth grade. Measures of number, counting, and arithmetic competencies were administered in early first grade and used to predict mathematics achievement through fifth (n = 177), while controlling for intelligence, working memory, and processing speed. Multilevel models revealed intelligence, processing speed, and the central executive component of working memory predicted achievement or achievement growth in mathematics and, as a contrast domain, word reading. The phonological loop was uniquely predictive of word reading and the visuospatial sketch pad of mathematics. Early fluency in processing and manipulating numerical set size and Arabic numerals, accurate use of sophisticated counting procedures for solving addition problems, and accuracy in making placements on a mathematical number line were uniquely predictive of mathematics achievement. Use of memory-based processes to solve addition problems predicted mathematics and reading achievement but in different ways. The results identify the early quantitative competencies that uniquely contribute to mathematics learning. PMID:21942667

  16. Procedural Documentation and Accuracy Assessment of Bathymetric Maps and Area/Capacity Tables for Small Reservoirs

    USGS Publications Warehouse

    Wilson, Gary L.; Richards, Joseph M.

    2006-01-01

    Because of the increasing use and importance of lakes for water supply to communities, a repeatable and reliable procedure to determine lake bathymetry and capacity is needed. A method to determine the accuracy of the procedure will help ensure proper collection and use of the data and resulting products. It is important to clearly define the intended products and desired accuracy before conducting the bathymetric survey to ensure proper data collection. A survey-grade echo sounder and differential global positioning system receivers were used to collect water-depth and position data in December 2003 at Sugar Creek Lake near Moberly, Missouri. Data were collected along planned transects, with an additional set of quality-assurance data collected for use in accuracy computations. All collected data were imported into a geographic information system database. A bathymetric surface model, contour map, and area/capacity tables were created from the geographic information system database. An accuracy assessment was completed on the collected data, bathymetric surface model, area/capacity table, and contour map products. Using established vertical accuracy standards, the accuracy of the collected data, bathymetric surface model, and contour map product was 0.67 foot, 0.91 foot, and 1.51 feet at the 95 percent confidence level. By comparing results from different transect intervals with the quality-assurance transect data, it was determined that a transect interval of 1 percent of the longitudinal length of Sugar Creek Lake produced nearly as good results as 0.5 percent transect interval for the bathymetric surface model, area/capacity table, and contour map products.

  17. The effect of clock, media, and station location errors on Doppler measurement accuracy

    NASA Technical Reports Server (NTRS)

    Miller, J. K.

    1993-01-01

    Doppler tracking by the Deep Space Network (DSN) is the primary radio metric data type used by navigation to determine the orbit of a spacecraft. The accuracy normally attributed to orbits determined exclusively with Doppler data is about 0.5 microradians in geocentric angle. Recently, the Doppler measurement system has evolved to a high degree of precision primarily because of tracking at X-band frequencies (7.2 to 8.5 GHz). However, the orbit determination system has not been able to fully utilize this improved measurement accuracy because of calibration errors associated with transmission media, the location of tracking stations on the Earth's surface, the orientation of the Earth as an observing platform, and timekeeping. With the introduction of Global Positioning System (GPS) data, it may be possible to remove a significant error associated with the troposphere. In this article, the effect of various calibration errors associated with transmission media, Earth platform parameters, and clocks are examined. With the introduction of GPS calibrations, it is predicted that a Doppler tracking accuracy of 0.05 microradians is achievable.

  18. Assessing the accuracy and stability of variable selection ...

    EPA Pesticide Factsheets

    Random forest (RF) modeling has emerged as an important statistical learning method in ecology due to its exceptional predictive performance. However, for large and complex ecological datasets there is limited guidance on variable selection methods for RF modeling. Typically, either a preselected set of predictor variables are used, or stepwise procedures are employed which iteratively add/remove variables according to their importance measures. This paper investigates the application of variable selection methods to RF models for predicting probable biological stream condition. Our motivating dataset consists of the good/poor condition of n=1365 stream survey sites from the 2008/2009 National Rivers and Stream Assessment, and a large set (p=212) of landscape features from the StreamCat dataset. Two types of RF models are compared: a full variable set model with all 212 predictors, and a reduced variable set model selected using a backwards elimination approach. We assess model accuracy using RF's internal out-of-bag estimate, and a cross-validation procedure with validation folds external to the variable selection process. We also assess the stability of the spatial predictions generated by the RF models to changes in the number of predictors, and argue that model selection needs to consider both accuracy and stability. The results suggest that RF modeling is robust to the inclusion of many variables of moderate to low importance. We found no substanti

  19. Can CT-based patient-matched instrumentation achieve consistent rotational alignment in knee arthroplasty?

    PubMed

    Tibesku, C O; Innocenti, B; Wong, P; Salehi, A; Labey, L

    2012-02-01

    Long-term success of contemporary total knee replacements relies to a large extent on proper implant alignment. This study was undertaken to test whether specimen-matched cutting blocks based on computed axial tomography (CT) scans could provide accurate rotational alignment of the femoral component. CT scans of five fresh frozen full leg cadaver specimens, equipped with infrared reflective markers, were used to produce a specimen-matched femoral cutting block. Using those blocks, the bone cuts were made to implant a bi-compartmental femoral component. Rotational alignment of the components in the horizontal plane was determined using an optical measurement system and compared with all relevant rotational reference axes identified on the CT scans. Average rotational alignment for the bi-compartmental component in the horizontal plane was 1.9° (range 0°-6.3°; standard deviation 2.6°). One specimen that showed the highest deviation from the planned alignment also featured a completely degraded medial articular surface. The CT-based specimen-matched cutting blocks achieved good rotational alignment accuracy except for one specimen with badly damaged cartilage. In such cases, imaging techniques that visualize the cartilage layer might be more suitable to design cutting blocks, as they will provide a better fit and increased surface support.

  20. Modeling Student Test-Taking Motivation in the Context of an Adaptive Achievement Test

    ERIC Educational Resources Information Center

    Wise, Steven L.; Kingsbury, G. Gage

    2016-01-01

    This study examined the utility of response time-based analyses in understanding the behavior of unmotivated test takers. For the data from an adaptive achievement test, patterns of observed rapid-guessing behavior and item response accuracy were compared to the behavior expected under several types of models that have been proposed to represent…

  1. Superior accuracy of model-based radiostereometric analysis for measurement of polyethylene wear

    PubMed Central

    Stilling, M.; Kold, S.; de Raedt, S.; Andersen, N. T.; Rahbek, O.; Søballe, K.

    2012-01-01

    Objectives The accuracy and precision of two new methods of model-based radiostereometric analysis (RSA) were hypothesised to be superior to a plain radiograph method in the assessment of polyethylene (PE) wear. Methods A phantom device was constructed to simulate three-dimensional (3D) PE wear. Images were obtained consecutively for each simulated wear position for each modality. Three commercially available packages were evaluated: model-based RSA using laser-scanned cup models (MB-RSA), model-based RSA using computer-generated elementary geometrical shape models (EGS-RSA), and PolyWare. Precision (95% repeatability limits) and accuracy (Root Mean Square Errors) for two-dimensional (2D) and 3D wear measurements were assessed. Results The precision for 2D wear measures was 0.078 mm, 0.102 mm, and 0.076 mm for EGS-RSA, MB-RSA, and PolyWare, respectively. For the 3D wear measures the precision was 0.185 mm, 0.189 mm, and 0.244 mm for EGS-RSA, MB-RSA, and PolyWare respectively. Repeatability was similar for all methods within the same dimension, when compared between 2D and 3D (all p > 0.28). For the 2D RSA methods, accuracy was below 0.055 mm and at least 0.335 mm for PolyWare. For 3D measurements, accuracy was 0.1 mm, 0.2 mm, and 0.3 mm for EGS-RSA, MB-RSA and PolyWare respectively. PolyWare was less accurate compared with RSA methods (p = 0.036). No difference was observed between the RSA methods (p = 0.10). Conclusions For all methods, precision and accuracy were better in 2D, with RSA methods being superior in accuracy. Although less accurate and precise, 3D RSA defines the clinically relevant wear pattern (multidirectional). PolyWare is a good and low-cost alternative to RSA, despite being less accurate and requiring a larger sample size. PMID:23610688

  2. Accuracy of Four Imaging Techniques for Diagnosis of Posterior Pelvic Floor Disorders.

    PubMed

    van Gruting, Isabelle M A; Stankiewicz, Aleksandra; Kluivers, Kirsten; De Bin, Riccardo; Blake, Helena; Sultan, Abdul H; Thakar, Ranee

    2017-11-01

    is not the best available imaging technique. There is no one optimal test for the diagnosis of all posterior pelvic floor disorders. Because transperineal and endovaginal ultrasonography have good test accuracy and patient acceptability, we suggest these could be used for initial assessment of obstructed defecation syndrome. ClinicalTrials.gov, NCT02239302.

  3. It Feels Good to Learn Where I Belong: School Belonging, Academic Emotions, and Academic Achievement in Adolescents

    ERIC Educational Resources Information Center

    Lam, Un Fong; Chen, Wei-Wen; Zhang, Jingqi; Liang, Ting

    2015-01-01

    This study examined the relationships between school belonging, academic emotions, and academic achievement in Macau adolescents. A survey of 406 junior high school students in Macau was used to collect information on the extent to which these students felt accepted and respected in their schools (school belonging), the emotions they experienced…

  4. The Accuracy and Reliability of Crowdsource Annotations of Digital Retinal Images.

    PubMed

    Mitry, Danny; Zutis, Kris; Dhillon, Baljean; Peto, Tunde; Hayat, Shabina; Khaw, Kay-Tee; Morgan, James E; Moncur, Wendy; Trucco, Emanuele; Foster, Paul J

    2016-09-01

    Crowdsourcing is based on outsourcing computationally intensive tasks to numerous individuals in the online community who have no formal training. Our aim was to develop a novel online tool designed to facilitate large-scale annotation of digital retinal images, and to assess the accuracy of crowdsource grading using this tool, comparing it to expert classification. We used 100 retinal fundus photograph images with predetermined disease criteria selected by two experts from a large cohort study. The Amazon Mechanical Turk Web platform was used to drive traffic to our site so anonymous workers could perform a classification and annotation task of the fundus photographs in our dataset after a short training exercise. Three groups were assessed: masters only, nonmasters only and nonmasters with compulsory training. We calculated the sensitivity, specificity, and area under the curve (AUC) of receiver operating characteristic (ROC) plots for all classifications compared to expert grading, and used the Dice coefficient and consensus threshold to assess annotation accuracy. In total, we received 5389 annotations for 84 images (excluding 16 training images) in 2 weeks. A specificity and sensitivity of 71% (95% confidence interval [CI], 69%-74%) and 87% (95% CI, 86%-88%) was achieved for all classifications. The AUC in this study for all classifications combined was 0.93 (95% CI, 0.91-0.96). For image annotation, a maximal Dice coefficient (∼0.6) was achieved with a consensus threshold of 0.25. This study supports the hypothesis that annotation of abnormalities in retinal images by ophthalmologically naive individuals is comparable to expert annotation. The highest AUC and agreement with expert annotation was achieved in the nonmasters with compulsory training group. The use of crowdsourcing as a technique for retinal image analysis may be comparable to expert graders and has the potential to deliver timely, accurate, and cost-effective image analysis.

  5. An Antenna with Good Electrical Properties and Artistic Shape for Lampshade

    NASA Astrophysics Data System (ADS)

    Zhou, Chang; Yu, Yang; Ji, Chen

    2018-06-01

    An improved transparent antenna based on transparent ceramic MgAl2O4 with artistic shape which can be used as lampshade is presented in this paper. A great peak gain and good pattern can be achieved by choosing the property shape and optimizing location of the feed of the antenna. Simulation results indicate that this antenna can achieve return loss >-15dB, peak gain >8 dBi at 2 GHz and 40% relative impedance bandwidth. Both the electrical properties and artistic shape of the antenna are realized and the lampshade which made by MgAl2O4 meets the requirement for communication, decoration and high light transmission.

  6. Making High Accuracy Null Depth Measurements for the LBTI ExoZodi Survey

    NASA Technical Reports Server (NTRS)

    Mennesson, Bertrand; Defrere, Denis; Nowak, Matthew; Hinz, Philip; Millan-Gabet, Rafael; Absil, Olivier; Bailey, Vanessa; Bryden, Geoffrey; Danchi, William; Kennedy, Grant M.; hide

    2016-01-01

    The characterization of exozodiacal light emission is both important for the understanding of planetary systems evolution and for the preparation of future space missions aiming to characterize low mass planets in the habitable zone of nearby main sequence stars. The Large Binocular Telescope Interferometer (LBTI) exozodi survey aims at providing a ten-fold improvement over current state of the art, measuring dust emission levels down to a typical accuracy of approximately 12 zodis per star, for a representative ensemble of approximately 30+ high priority targets. Such measurements promise to yield a final accuracy of about 2 zodis on the median exozodi level of the targets sample. Reaching a 1 sigma measurement uncertainty of 12 zodis per star corresponds to measuring interferometric cancellation (null) levels, i.e visibilities at the few 100 ppm uncertainty level. We discuss here the challenges posed by making such high accuracy mid-infrared visibility measurements from the ground and present the methodology we developed for achieving current best levels of 500 ppm or so. We also discuss current limitations and plans for enhanced exozodi observations over the next few years at LBTI.

  7. Accuracy assessment of linear spectral mixture model due to terrain undulation

    NASA Astrophysics Data System (ADS)

    Wang, Tianxing; Chen, Songlin; Ma, Ya

    2008-12-01

    Mixture spectra are common in remote sensing due to the limitations of spatial resolution and the heterogeneity of land surface. During the past 30 years, a lot of subpixel model have developed to investigate the information within mixture pixels. Linear spectral mixture model (LSMM) is a simper and more general subpixel model. LSMM also known as spectral mixture analysis is a widely used procedure to determine the proportion of endmembers (constituent materials) within a pixel based on the endmembers' spectral characteristics. The unmixing accuracy of LSMM is restricted by variety of factors, but now the research about LSMM is mostly focused on appraisement of nonlinear effect relating to itself and techniques used to select endmembers, unfortunately, the environment conditions of study area which could sway the unmixing-accuracy, such as atmospheric scatting and terrain undulation, are not studied. This paper probes emphatically into the accuracy uncertainty of LSMM resulting from the terrain undulation. ASTER dataset was chosen and the C terrain correction algorithm was applied to it. Based on this, fractional abundances for different cover types were extracted from both pre- and post-C terrain illumination corrected ASTER using LSMM. Simultaneously, the regression analyses and the IKONOS image were introduced to assess the unmixing accuracy. Results showed that terrain undulation could dramatically constrain the application of LSMM in mountain area. Specifically, for vegetation abundances, a improved unmixing accuracy of 17.6% (regression against to NDVI) and 18.6% (regression against to MVI) for R2 was achieved respectively by removing terrain undulation. Anyway, this study indicated in a quantitative way that effective removal or minimization of terrain illumination effects was essential for applying LSMM. This paper could also provide a new instance for LSMM applications in mountainous areas. In addition, the methods employed in this study could be

  8. Enhanced perceived responsibility decreases metamemory but not memory accuracy in obsessive-compulsive disorder (OCD).

    PubMed

    Moritz, S; Wahl, K; Zurowski, B; Jelinek, L; Hand, I; Fricke, S

    2007-09-01

    Mixed findings have been obtained in prior research with respect to the presence and severity of memory and metamemory deficits in obsessive-compulsive disorder (OCD). We tested the hypothesis that experimentally induced increments of subjective responsibility would lead to a disproportionately strong decline of memory confidence and enhanced response latencies in OCD while leaving memory accuracy unaffected. Twenty-eight OCD patients and 28 healthy controls were presented a computerized memory test framed with two different scenarios. In the neutral scenario, the participant was requested to imagine purchasing 15 items from a do-it-yourself store. In the recognition phase, the 15 needed items were presented along with 15 distractor items. The participant was asked to decide whether items were on his or her shopping list or not, graded by subjective confidence. In the responsibility scenario, the general experimental setup was analogous except that the participant now had to envision that he or she was a helper in a region recently struck by an earthquake, dispatched to provide 15 urgently needed goods from a nearby town. In line with prior work by our group, samples did not differ in either condition on memory accuracy in a subsequent recognition task. As hypothesized, OCD participants were less certain in their responses for the high responsibility condition than controls. Whereas patients and controls did not differ in their subjective estimates for memorized items, patients expressed stronger doubt that their earthquake mission was successful. The findings indicate that low memory confidence in OCD may only be elicited in situations where perceived responsibility is high and that patients may share higher performance standards ("good is not good enough") than controls when perceived responsibility is inflated.

  9. Emerging Good Practices for Transforming Value Assessment: Patients' Voices, Patients' Values.

    PubMed

    Perfetto, Eleanor M; Harris, Jason; Mullins, C Daniel; dosReis, Susan

    2018-04-01

    Patient engagement is a transformative strategy for improving value assessment. US value framework developers have increased engagement activities, but more needs to be learned about how to best achieve meaningful patient engagement in value assessment. The objective was to glean good practices in patient engagement emerging from patient community experiences, to be used in value assessment. The National Health Council Value Workgroup conducted a survey and held a focus group with its member advocacy organizations to gather experiences with value framework developers and views on emerging good practices. Ten of 13 organizations completed the survey; reporting 13 interactions with four framework developers. Most rated experiences as "good" to "very good." Emerging good practices included (1) engage early; (2) engage a range of patients; (3) leverage patient-provided information, data resources, and outreach mechanisms; (4) be transparent; and (5) appreciate and accommodate resource constraints. Twelve of 13 organizations participated in the focus group, and this produced 30 emerging good practices in four areas: (1) timing; (2) methodology and data; (3) partnering; and (4) characterizing engagement. Patient engagement was limited in early development of value frameworks but has increased in the past few years. Patient groups report positive experiences that can serve as emerging good practices. These groups also reported experienced challenges in their interactions and recommended good practices to mitigate those challenges. The growing pool of patient engagement experiences can be translated into good practices to advance a patient-centered, value-driven health care ecosystem. Lessons learned from these early experiences can help establish recommend emerging good practices that can eventually result in best practices and standards in the field. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc

  10. High-accuracy reference standards for two-photon absorption in the 680–1050 nm wavelength range

    PubMed Central

    de Reguardati, Sophie; Pahapill, Juri; Mikhailov, Alexander; Stepanenko, Yuriy; Rebane, Aleksander

    2016-01-01

    Degenerate two-photon absorption (2PA) of a series of organic fluorophores is measured using femtosecond fluorescence excitation method in the wavelength range, λ2PA = 680–1050 nm, and ~100 MHz pulse repetition rate. The function of relative 2PA spectral shape is obtained with estimated accuracy 5%, and the absolute 2PA cross section is measured at selected wavelengths with the accuracy 8%. Significant improvement of the accuracy is achieved by means of rigorous evaluation of the quadratic dependence of the fluorescence signal on the incident photon flux in the whole wavelength range, by comparing results obtained from two independent experiments, as well as due to meticulous evaluation of critical experimental parameters, including the excitation spatial- and temporal pulse shape, laser power and sample geometry. Application of the reference standards in nonlinear transmittance measurements is discussed. PMID:27137334

  11. Improving orbit prediction accuracy through supervised machine learning

    NASA Astrophysics Data System (ADS)

    Peng, Hao; Bai, Xiaoli

    2018-05-01

    Due to the lack of information such as the space environment condition and resident space objects' (RSOs') body characteristics, current orbit predictions that are solely grounded on physics-based models may fail to achieve required accuracy for collision avoidance and have led to satellite collisions already. This paper presents a methodology to predict RSOs' trajectories with higher accuracy than that of the current methods. Inspired by the machine learning (ML) theory through which the models are learned based on large amounts of observed data and the prediction is conducted without explicitly modeling space objects and space environment, the proposed ML approach integrates physics-based orbit prediction algorithms with a learning-based process that focuses on reducing the prediction errors. Using a simulation-based space catalog environment as the test bed, the paper demonstrates three types of generalization capability for the proposed ML approach: (1) the ML model can be used to improve the same RSO's orbit information that is not available during the learning process but shares the same time interval as the training data; (2) the ML model can be used to improve predictions of the same RSO at future epochs; and (3) the ML model based on a RSO can be applied to other RSOs that share some common features.

  12. Speed-accuracy trade-off in a trajectory-constrained self-feeding task: a quantitative index of unsuppressed motor noise in children with dystonia

    PubMed Central

    Lunardini, Francesca; Bertucco, Matteo; Casellato, Claudia; Bhanpuri, Nasir; Pedrocchi, Alessandra; Sanger, Terence D.

    2015-01-01

    Motor speed and accuracy are both affected in childhood dystonia. Thus, deriving a speed-accuracy function is an important metric for assessing motor impairments in dystonia. Previous work in dystonia studied the speed-accuracy trade-off during point-to-point tasks. To achieve a more relevant measurement of functional abilities in dystonia, the present study investigates upper-limb kinematics and electromyographic activity of 8 children with dystonia and 8 healthy children during a trajectory-constrained child-relevant task that emulates self-feeding with a spoon and requires continuous monitoring of accuracy. The speed-accuracy trade-off is examined by changing the spoon size to create different accuracy demands. Results demonstrate that the trajectory-constrained speed-accuracy relation is present in both groups, but it is altered in dystonia in terms of increased slope and offset towards longer movement times. Findings are consistent with the hypothesis of increased signal-dependent noise in dystonia, which may partially explain the slow and variable movements observed in dystonia. PMID:25895910

  13. Accuracy and speed of orthographic processing in persons with developmental dyslexia.

    PubMed

    King, Wayne M; Lombardino, Linda L; Ahmed, Sarah

    2005-08-01

    A group of 39 persons (20 male and 19 female, 11.0 to 32.5 yr.) with developmental dyslexia and 42 controls (21 male and 21 female, 11.2 to 32.3 years) were compared on computerized tests of sight word reading, nonword decoding, and spelling recognition. The subjects with developmental dyslexia performed significantly slower and less accurately than controls on all tasks. Further, the effect size of the group differences was larger for the older group. Within-group analyses showed a significant difference by age group on accuracy. Only the control group showed a significant age difference between groups on response time. Mean accuracy and response times for the reading-disabled subjects resembled shifted versions of the control group means. These results agree with previous reports that phonological deficits persist for reading-disabled adults and suggest a test of whether the discrepancy between reading-disabled and typically achieving readers may actually increase across age groups.

  14. Social Power Increases Interoceptive Accuracy

    PubMed Central

    Moeini-Jazani, Mehrad; Knoeferle, Klemens; de Molière, Laura; Gatti, Elia; Warlop, Luk

    2017-01-01

    Building on recent psychological research showing that power increases self-focused attention, we propose that having power increases accuracy in perception of bodily signals, a phenomenon known as interoceptive accuracy. Consistent with our proposition, participants in a high-power experimental condition outperformed those in the control and low-power conditions in the Schandry heartbeat-detection task. We demonstrate that the effect of power on interoceptive accuracy is not explained by participants’ physiological arousal, affective state, or general intention for accuracy. Rather, consistent with our reasoning that experiencing power shifts attentional resources inward, we show that the effect of power on interoceptive accuracy is dependent on individuals’ chronic tendency to focus on their internal sensations. Moreover, we demonstrate that individuals’ chronic sense of power also predicts interoceptive accuracy similar to, and independent of, how their situationally induced feeling of power does. We therefore provide further support on the relation between power and enhanced perception of bodily signals. Our findings offer a novel perspective–a psychophysiological account–on how power might affect judgments and behavior. We highlight and discuss some of these intriguing possibilities for future research. PMID:28824501

  15. Climate sensitivity uncertainty: when is good news bad?

    PubMed

    Freeman, Mark C; Wagner, Gernot; Zeckhauser, Richard J

    2015-11-28

    Climate change is real and dangerous. Exactly how bad it will get, however, is uncertain. Uncertainty is particularly relevant for estimates of one of the key parameters: equilibrium climate sensitivity--how eventual temperatures will react as atmospheric carbon dioxide concentrations double. Despite significant advances in climate science and increased confidence in the accuracy of the range itself, the 'likely' range has been 1.5-4.5°C for over three decades. In 2007, the Intergovernmental Panel on Climate Change (IPCC) narrowed it to 2-4.5°C, only to reverse its decision in 2013, reinstating the prior range. In addition, the 2013 IPCC report removed prior mention of 3°C as the 'best estimate'. We interpret the implications of the 2013 IPCC decision to lower the bottom of the range and excise a best estimate. Intuitively, it might seem that a lower bottom would be good news. Here we ask: when might apparently good news about climate sensitivity in fact be bad news in the sense that it lowers societal well-being? The lowered bottom value also implies higher uncertainty about the temperature increase, definitely bad news. Under reasonable assumptions, both the lowering of the lower bound and the removal of the 'best estimate' may well be bad news. © 2015 The Author(s).

  16. The experience of a good day: a phenomenological study to explain a good day as experienced by a newly qualified RN.

    PubMed

    Jackson, Carole

    2005-04-01

    The main aim of this study was to provide an explanation of the newly qualified nurse's experience and description of a good day. Secondly, it sought to provide an explanation of how a good day made them feel about nursing. By identifying the main components of a good day and what positively effects the experience of a working day for a newly qualified nurse, it may be possible to move towards an increase in the occurrence of the components and emulation of a good day. While there is evidence to suggest that positive experiences within nursing increase job satisfaction and aid retention to the profession, the experience of a good day and what constitutes a good day for a newly qualified nurse has not been explored. The main components of a good day have not been identified and no work has been carried out to ascertain how these days make nurses feel about their chosen career. The aims of the study lent themselves to a phenomenological descriptive approach to research, the objective of which is identification of the essence of behaviour. Eight newly qualified nurses agreed to take part in the research. Each participant was interviewed twice, and in addition one group interview was arranged to clarify themes. The interviews, which were audio taped, were informal allowing the participants to answer in an open and unstructured manner. Once completed, all the tapes were transcribed and immersion and analysis of the data led to 5 themes naturally emerging as the components of a good day. The identified themes were, doing something well, good relationships with patients, feeling that you've achieved something, getting the work done and you need team work. In addition, although not a theme of a good day but of great importance was the description of 'that wonderful feeling at the end of a good day'. These themes contributed to feelings of job satisfaction and the pleasure of nursing. More specifically the concept of knowing the patient both from a personal level and

  17. Diagnostic Accuracy, Sensitivity, and Specificity of Executive Function Tests in Moderate Traumatic Brain Injury in Ghana.

    PubMed

    Adjorlolo, Samuel

    2018-06-01

    The sociocultural differences between Western and sub-Saharan African countries make it imperative to standardize neuropsychological tests in the latter. However, Western-normed tests are frequently administered in sub-Saharan Africa because of challenges hampering standardization efforts. Yet a salient topical issue in the cross-cultural neuropsychology literature relates to the utility of Western-normed neuropsychological tests in minority groups, non-Caucasians, and by extension Ghanaians. Consequently, this study investigates the diagnostic accuracy, sensitivity, and specificity of executive function (EF) tests (The Stroop Test, Trail Making Test, and Controlled Oral Word Association Test), and a Revised Quick Cognitive Screening Test (RQCST) in a sample of 50 patients diagnosed with moderate traumatic brain injury and 50 healthy controls in Ghana. The EF test scores showed good diagnostic accuracy, with area under the curve (AUC) values of the Trail Making Test scores ranging from .746 to .902. With respect to the Stroop Test scores, the AUC values ranged from .793 to .898, while Controlled Oral Word Association Test had AUC value of .787. The RQCST scores discriminated between the groups, with AUC values ranging from .674 to .912. The AUC values of composite EF score and a neuropsychological score created from EF and RQCST scores were .936 and. 942, respectively. Additionally, the Stroop Test, Trail Making Test, EF composite score, and RQCST scores showed good to excellent sensitivities and specificities. In general, this study has shown that commonly used EF tests in Western countries have diagnostic accuracy, sensitivity, and specificity when administered in Ghanaian samples. The findings and implications of the study are discussed.

  18. Cambodian Early Adolescents' Academic Achievement: The Role of Social Capital

    ERIC Educational Resources Information Center

    Eng, Sothy

    2013-01-01

    This study examined the associations of parents' cultural beliefs and attitudes with respect to fate, traditional gender roles, aspirations, and involvement in children's academic achievement in Cambodia. Based on Coleman's social capital theory, a good parent-child relationship enables children's school success because resources are created as a…

  19. Design of interpolation functions for subpixel-accuracy stereo-vision systems.

    PubMed

    Haller, Istvan; Nedevschi, Sergiu

    2012-02-01

    Traditionally, subpixel interpolation in stereo-vision systems was designed for the block-matching algorithm. During the evaluation of different interpolation strategies, a strong correlation was observed between the type of the stereo algorithm and the subpixel accuracy of the different solutions. Subpixel interpolation should be adapted to each stereo algorithm to achieve maximum accuracy. In consequence, it is more important to propose methodologies for interpolation function generation than specific function shapes. We propose two such methodologies based on data generated by the stereo algorithms. The first proposal uses a histogram to model the environment and applies histogram equalization to an existing solution adapting it to the data. The second proposal employs synthetic images of a known environment and applies function fitting to the resulted data. The resulting function matches the algorithm and the data as best as possible. An extensive evaluation set is used to validate the findings. Both real and synthetic test cases were employed in different scenarios. The test results are consistent and show significant improvements compared with traditional solutions. © 2011 IEEE

  20. Accuracy of maxillary positioning after standard and inverted orthognathic sequencing.

    PubMed

    Ritto, Fabio G; Ritto, Thiago G; Ribeiro, Danilo Passeado; Medeiros, Paulo José; de Moraes, Márcio

    2014-05-01

    This study aimed to compare the accuracy of maxillary positioning after bimaxillary orthognathic surgery, using 2 sequences. A total of 80 cephalograms (40 preoperative and 40 postoperative) from 40 patients were analyzed. Group 1 included radiographs of patients submitted to conventional sequence, whereas group 2 patients were submitted to inverted sequence. The final position of the maxillary central incisor was obtained after vertical and horizontal measurements of the tracings, and it was compared with what had been planned. The null hypothesis, which stated that there would be no difference between the groups, was tested. After applying the Welch t test for comparison of mean differences between maxillary desired and achieved position, considering a statistical significance of 5% and a 2-tailed test, the null hypothesis was not rejected (P > .05). Thus, there was no difference in the accuracy of maxillary positioning between groups. Conventional and inverted sequencing proved to be reliable in positioning the maxilla after LeFort I osteotomy in bimaxillary orthognathic surgeries. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. 19 CFR 10.605 - Goods classifiable as goods put up in sets.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...-Central America-United States Free Trade Agreement Rules of Origin § 10.605 Goods classifiable as goods... 19 Customs Duties 1 2010-04-01 2010-04-01 false Goods classifiable as goods put up in sets. 10.605 Section 10.605 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY...

  2. Analysis of deformable image registration accuracy using computational modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhong Hualiang; Kim, Jinkoo; Chetty, Indrin J.

    2010-03-15

    Computer aided modeling of anatomic deformation, allowing various techniques and protocols in radiation therapy to be systematically verified and studied, has become increasingly attractive. In this study the potential issues in deformable image registration (DIR) were analyzed based on two numerical phantoms: One, a synthesized, low intensity gradient prostate image, and the other a lung patient's CT image data set. Each phantom was modeled with region-specific material parameters with its deformation solved using a finite element method. The resultant displacements were used to construct a benchmark to quantify the displacement errors of the Demons and B-Spline-based registrations. The results showmore » that the accuracy of these registration algorithms depends on the chosen parameters, the selection of which is closely associated with the intensity gradients of the underlying images. For the Demons algorithm, both single resolution (SR) and multiresolution (MR) registrations required approximately 300 iterations to reach an accuracy of 1.4 mm mean error in the lung patient's CT image (and 0.7 mm mean error averaged in the lung only). For the low gradient prostate phantom, these algorithms (both SR and MR) required at least 1600 iterations to reduce their mean errors to 2 mm. For the B-Spline algorithms, best performance (mean errors of 1.9 mm for SR and 1.6 mm for MR, respectively) on the low gradient prostate was achieved using five grid nodes in each direction. Adding more grid nodes resulted in larger errors. For the lung patient's CT data set, the B-Spline registrations required ten grid nodes in each direction for highest accuracy (1.4 mm for SR and 1.5 mm for MR). The numbers of iterations or grid nodes required for optimal registrations depended on the intensity gradients of the underlying images. In summary, the performance of the Demons and B-Spline registrations have been quantitatively evaluated using numerical phantoms. The results show that

  3. Student perceptions of a good teacher: the gender perspective.

    PubMed

    Jules, V; Kutnick, P

    1997-12-01

    A large-scale survey of pupils' perceptions of a good teacher in the Caribbean republic of Trinidad and Tobago is reported. An essay-based, interpretative mode of research was used to elicit and identify constructs used by boys and girls. The study explores similarities and differences between boys and girls in their perceptions of a good teacher, in a society where girls achieve superior academic performance (than boys). A total of 1756 pupils and students aged between 8 and 16 provided the sample, which was proportional, stratified, clustered. Within these constraints classrooms were randomly selected to be representative of primary and secondary schools across the two islands. Altogether 1539 essays and 217 interviews were content analysed, coded for age development and compared between boys and girls. Content items identified by the pupils were logically grouped into: physical and personal characteristics of the teacher, quality of the relationship between the teacher and pupil, control of behaviour by the teacher, descriptions of the teaching process, and educational and other outcomes obtained by pupils due to teacher efforts. Female pupils identified more good teacher concepts at all age levels than males. There was some commonality between the sexes in concepts regarding interpersonal relationships and inclusiveness in the good teachers' teaching practices and boys showed significantly greater concerns regarding teacher control and use of punishment. Males as young as 8 years stated that good teachers should be sensitive to their needs. Only among the 16-year-old males were males noted as good teachers. Consideration is given to the roles of male and female teachers, how their classroom actions may set the basis for future success (or failure) of their pupils, and the needs of pupils with regard to teacher support within developing and developed countries.

  4. Recognising `good at mathematics': using a performative lens for identity

    NASA Astrophysics Data System (ADS)

    Darragh, Lisa

    2015-03-01

    Many students do not recognise in themselves positive learner identities in mathematics and thus exclude themselves from further mathematics education, limiting their life opportunities. In this study, I use a performance metaphor for identity, drawing on G.H. Mead, Erving Goffman and Judith Butler to analyse interviews with students, taken at four time points as they make the transition from primary to secondary school. The question I focus on is `How do you recognise someone who is "good at mathematics"?' The students' responses reveal that there is a wide variety of scripts available when enacting the role of `good at mathematics', and these include getting high marks, knowing the answer quickly, helping others and demonstrating the confidence to put up their hand to answer questions. Despite the variety of ways in which to demonstrate `good at mathematics', most of the students did not recognise themselves in their own descriptions. This goes some way towards explaining why students may opt out of further study in mathematics, despite high achievement in this subject.

  5. Improvement of SLR accuracy, a possible new step

    NASA Technical Reports Server (NTRS)

    Kasser, Michel

    1993-01-01

    The satellite laser ranging (SLR) technology experienced a large number of technical improvements since the early 1970's, leading now to a millimetric instrumental accuracy. Presently, it appears as useless to increase these instrumental performances as long as the atmospheric propagation delay suffers its actual imprecision. It has been proposed for many years to work in multiwavelength mode, but up to now the considerable technological difficulties of subpicosecond timing have seriously delayed such an approach. Then a new possibility is proposed, using a device which is not optimized now for SLR but has already given good results in the lower troposphere for wind measurement: the association of a radar and a sodar. While waiting for the 2-lambda methodology, this one could provide an atmospheric propagation delay at the millimeter level during a few years with only little technological investment.

  6. Accuracy of Perceptual and Acoustic Methods for the Detection of Inspiratory Loci in Spontaneous Speech

    PubMed Central

    Wang, Yu-Tsai; Nip, Ignatius S. B.; Green, Jordan R.; Kent, Ray D.; Kent, Jane Finley; Ullman, Cara

    2012-01-01

    The current study investigates the accuracy of perceptually and acoustically determined inspiratory loci in spontaneous speech for the purpose of identifying breath groups. Sixteen participants were asked to talk about simple topics in daily life at a comfortable speaking rate and loudness while connected to a pneumotach and audio microphone. The locations of inspiratory loci were determined based on the aerodynamic signal, which served as a reference for loci identified perceptually and acoustically. Signal detection theory was used to evaluate the accuracy of the methods. The results showed that the greatest accuracy in pause detection was achieved (1) perceptually based on the agreement between at least 2 of the 3 judges; (2) acoustically using a pause duration threshold of 300 ms. In general, the perceptually-based method was more accurate than was the acoustically-based method. Inconsistencies among perceptually-determined, acoustically-determined, and aerodynamically-determined inspiratory loci for spontaneous speech should be weighed in selecting a method of breath-group determination. PMID:22362007

  7. "Good mothering" or "good citizenship"?

    PubMed

    Porter, Maree; Kerridge, Ian H; Jordens, Christopher F C

    2012-03-01

    Umbilical cord blood banking is one of many biomedical innovations that confront pregnant women with new choices about what they should do to secure their own and their child's best interests. Many mothers can now choose to donate their baby's umbilical cord blood (UCB) to a public cord blood bank or pay to store it in a private cord blood bank. Donation to a public bank is widely regarded as an altruistic act of civic responsibility. Paying to store UCB may be regarded as a "unique opportunity" to provide "insurance" for the child's future. This paper reports findings from a survey of Australian women that investigated the decision to either donate or store UCB. We conclude that mothers are faced with competing discourses that force them to choose between being a "good mother" and fulfilling their role as a "good citizen." We discuss this finding with reference to the concept of value pluralism.

  8. Moderate-to-Vigorous Physical Activity, Indices of Cognitive Control, and Academic Achievement in Preadolescents.

    PubMed

    Pindus, Dominika M; Drollette, Eric S; Scudder, Mark R; Khan, Naiman A; Raine, Lauren B; Sherar, Lauren B; Esliger, Dale W; Kramer, Arthur F; Hillman, Charles H

    2016-06-01

    To assess whether preadolescents' objectively measured moderate-to-vigorous physical activity (MVPA) is associated with cognitive control and academic achievement, independent of aerobic fitness. A sample of 74 children (Meanage = 8.64 years, SD = .58, 46% girls) were included in the analyses. Daily MVPA (min/d) was measured over 7 days using ActiGraph wGT3X+ accelerometer. Aerobic fitness was measured using a maximal graded exercise test and expressed as maximal oxygen uptake (mL*kg(-1)*min(-1)). Inhibitory control was measured with a modified Eriksen flanker task (reaction time and accuracy), and working memory with an Operation Span Task (accuracy scores). Academic achievement (in reading, mathematics, and spelling) was expressed as standardized scores on the Kaufman Test of Educational Achievement. The relationships were assessed using hierarchical regression models adjusting for aerobic fitness and other covariates. No significant associations were found between MVPA and inhibition, working memory, or academic achievement. Aerobic fitness was positively associated with inhibitory control (P = .02) and spelling (P = .04) but not with other cognitive or academic variables (all P > .05). Aerobic fitness, rather than daily MVPA, is positively associated with childhood ability to manage perceptual interference and spelling. Further research into the associations between objectively measured MVPA and cognitive and academic outcomes in children while controlling for important covariates is needed. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Inertial Measures of Motion for Clinical Biomechanics: Comparative Assessment of Accuracy under Controlled Conditions - Effect of Velocity

    PubMed Central

    Lebel, Karina; Boissy, Patrick; Hamel, Mathieu; Duval, Christian

    2013-01-01

    Background Inertial measurement of motion with Attitude and Heading Reference Systems (AHRS) is emerging as an alternative to 3D motion capture systems in biomechanics. The objectives of this study are: 1) to describe the absolute and relative accuracy of multiple units of commercially available AHRS under various types of motion; and 2) to evaluate the effect of motion velocity on the accuracy of these measurements. Methods The criterion validity of accuracy was established under controlled conditions using an instrumented Gimbal table. AHRS modules were carefully attached to the center plate of the Gimbal table and put through experimental static and dynamic conditions. Static and absolute accuracy was assessed by comparing the AHRS orientation measurement to those obtained using an optical gold standard. Relative accuracy was assessed by measuring the variation in relative orientation between modules during trials. Findings Evaluated AHRS systems demonstrated good absolute static accuracy (mean error < 0.5o) and clinically acceptable absolute accuracy under condition of slow motions (mean error between 0.5o and 3.1o). In slow motions, relative accuracy varied from 2o to 7o depending on the type of AHRS and the type of rotation. Absolute and relative accuracy were significantly affected (p<0.05) by velocity during sustained motions. The extent of that effect varied across AHRS. Interpretation Absolute and relative accuracy of AHRS are affected by environmental magnetic perturbations and conditions of motions. Relative accuracy of AHRS is mostly affected by the ability of all modules to locate the same global reference coordinate system at all time. Conclusions Existing AHRS systems can be considered for use in clinical biomechanics under constrained conditions of use. While their individual capacity to track absolute motion is relatively consistent, the use of multiple AHRS modules to compute relative motion between rigid bodies needs to be optimized according to

  10. Systematic review of discharge coding accuracy

    PubMed Central

    Burns, E.M.; Rigby, E.; Mamidanna, R.; Bottle, A.; Aylin, P.; Ziprin, P.; Faiz, O.D.

    2012-01-01

    Introduction Routinely collected data sets are increasingly used for research, financial reimbursement and health service planning. High quality data are necessary for reliable analysis. This study aims to assess the published accuracy of routinely collected data sets in Great Britain. Methods Systematic searches of the EMBASE, PUBMED, OVID and Cochrane databases were performed from 1989 to present using defined search terms. Included studies were those that compared routinely collected data sets with case or operative note review and those that compared routinely collected data with clinical registries. Results Thirty-two studies were included. Twenty-five studies compared routinely collected data with case or operation notes. Seven studies compared routinely collected data with clinical registries. The overall median accuracy (routinely collected data sets versus case notes) was 83.2% (IQR: 67.3–92.1%). The median diagnostic accuracy was 80.3% (IQR: 63.3–94.1%) with a median procedure accuracy of 84.2% (IQR: 68.7–88.7%). There was considerable variation in accuracy rates between studies (50.5–97.8%). Since the 2002 introduction of Payment by Results, accuracy has improved in some respects, for example primary diagnoses accuracy has improved from 73.8% (IQR: 59.3–92.1%) to 96.0% (IQR: 89.3–96.3), P= 0.020. Conclusion Accuracy rates are improving. Current levels of reported accuracy suggest that routinely collected data are sufficiently robust to support their use for research and managerial decision-making. PMID:21795302

  11. The reliability, accuracy and minimal detectable difference of a multi-segment kinematic model of the foot-shoe complex.

    PubMed

    Bishop, Chris; Paul, Gunther; Thewlis, Dominic

    2013-04-01

    Kinematic models are commonly used to quantify foot and ankle kinematics, yet no marker sets or models have been proven reliable or accurate when wearing shoes. Further, the minimal detectable difference of a developed model is often not reported. We present a kinematic model that is reliable, accurate and sensitive to describe the kinematics of the foot-shoe complex and lower leg during walking gait. In order to achieve this, a new marker set was established, consisting of 25 markers applied on the shoe and skin surface, which informed a four segment kinematic model of the foot-shoe complex and lower leg. Three independent experiments were conducted to determine the reliability, accuracy and minimal detectable difference of the marker set and model. Inter-rater reliability of marker placement on the shoe was proven to be good to excellent (ICC=0.75-0.98) indicating that markers could be applied reliably between raters. Intra-rater reliability was better for the experienced rater (ICC=0.68-0.99) than the inexperienced rater (ICC=0.38-0.97). The accuracy of marker placement along each axis was <6.7 mm for all markers studied. Minimal detectable difference (MDD90) thresholds were defined for each joint; tibiocalcaneal joint--MDD90=2.17-9.36°, tarsometatarsal joint--MDD90=1.03-9.29° and the metatarsophalangeal joint--MDD90=1.75-9.12°. These thresholds proposed are specific for the description of shod motion, and can be used in future research designed at comparing between different footwear. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Unifying Speed-Accuracy Trade-Off and Cost-Benefit Trade-Off in Human Reaching Movements.

    PubMed

    Peternel, Luka; Sigaud, Olivier; Babič, Jan

    2017-01-01

    Two basic trade-offs interact while our brain decides how to move our body. First, with the cost-benefit trade-off, the brain trades between the importance of moving faster toward a target that is more rewarding and the increased muscular cost resulting from a faster movement. Second, with the speed-accuracy trade-off, the brain trades between how accurate the movement needs to be and the time it takes to achieve such accuracy. So far, these two trade-offs have been well studied in isolation, despite their obvious interdependence. To overcome this limitation, we propose a new model that is able to simultaneously account for both trade-offs. The model assumes that the central nervous system maximizes the expected utility resulting from the potential reward and the cost over the repetition of many movements, taking into account the probability to miss the target. The resulting model is able to account for both the speed-accuracy and the cost-benefit trade-offs. To validate the proposed hypothesis, we confront the properties of the computational model to data from an experimental study where subjects have to reach for targets by performing arm movements in a horizontal plane. The results qualitatively show that the proposed model successfully accounts for both cost-benefit and speed-accuracy trade-offs.

  13. A Dataset from TIMSS to Examine the Relationship between Computer Use and Mathematics Achievement

    ERIC Educational Resources Information Center

    Kadijevich, Djordje M.

    2015-01-01

    Because the relationship between computer use and achievement is still puzzling, there is a need to prepare and analyze good quality datasets on computer use and achievement. Such a dataset can be derived from TIMSS data. This paper describes how this dataset can be prepared. It also gives an example of how the dataset may be analyzed. The…

  14. High-accuracy contouring using projection moiré

    NASA Astrophysics Data System (ADS)

    Sciammarella, Cesar A.; Lamberti, Luciano; Sciammarella, Federico M.

    2005-09-01

    Shadow and projection moiré are the oldest forms of moiré to be used in actual technical applications. In spite of this fact and the extensive number of papers that have been published on this topic, the use of shadow moiré as an accurate tool that can compete with alternative devices poses very many problems that go to the very essence of the mathematical models used to obtain contour information from fringe pattern data. In this paper some recent developments on the projection moiré method are presented. Comparisons between the results obtained with the projection method and the results obtained by mechanical devices that operate with contact probes are presented. These results show that the use of projection moiré makes it possible to achieve the same accuracy that current mechanical touch probe devices can provide.

  15. Accuracy of visual estimates of joint angle and angular velocity using criterion movements.

    PubMed

    Morrison, Craig S; Knudson, Duane; Clayburn, Colby; Haywood, Philip

    2005-06-01

    A descriptive study to document undergraduate physical education majors' (22.8 +/- 2.4 yr. old) estimates of sagittal plane elbow angle and angular velocity of elbow flexion visually was performed. 42 subjects rated videotape replays of 30 movements organized into three speeds of movement and two criterion elbow angles. Video images of the movements were analyzed with Peak Motus to measure actual values of elbow angles and peak angular velocity. Of the subjects 85.7% had speed ratings significantly correlated with true peak elbow angular velocity in all three angular velocity conditions. Few (16.7%) subjects' ratings of elbow angle correlated significantly with actual angles. Analysis of the subjects with good ratings showed the accuracy of visual ratings was significantly related to speed, with decreasing accuracy for slower speeds of movement. The use of criterion movements did not improve the small percentage of novice observers who could accurately estimate body angles during movement.

  16. Using meta-analysis to inform the design of subsequent studies of diagnostic test accuracy.

    PubMed

    Hinchliffe, Sally R; Crowther, Michael J; Phillips, Robert S; Sutton, Alex J

    2013-06-01

    An individual diagnostic accuracy study rarely provides enough information to make conclusive recommendations about the accuracy of a diagnostic test; particularly when the study is small. Meta-analysis methods provide a way of combining information from multiple studies, reducing uncertainty in the result and hopefully providing substantial evidence to underpin reliable clinical decision-making. Very few investigators consider any sample size calculations when designing a new diagnostic accuracy study. However, it is important to consider the number of subjects in a new study in order to achieve a precise measure of accuracy. Sutton et al. have suggested previously that when designing a new therapeutic trial, it could be more beneficial to consider the power of the updated meta-analysis including the new trial rather than of the new trial itself. The methodology involves simulating new studies for a range of sample sizes and estimating the power of the updated meta-analysis with each new study added. Plotting the power values against the range of sample sizes allows the clinician to make an informed decision about the sample size of a new trial. This paper extends this approach from the trial setting and applies it to diagnostic accuracy studies. Several meta-analytic models are considered including bivariate random effects meta-analysis that models the correlation between sensitivity and specificity. Copyright © 2012 John Wiley & Sons, Ltd. Copyright © 2012 John Wiley & Sons, Ltd.

  17. Factors Predicting a Good Symptomatic Outcome After Prostate Artery Embolisation (PAE).

    PubMed

    Maclean, D; Harris, M; Drake, T; Maher, B; Modi, S; Dyer, J; Somani, B; Hacking, N; Bryant, T

    2018-02-26

    As prostate artery embolisation (PAE) becomes an established treatment for benign prostatic obstruction, factors predicting good symptomatic outcome remain unclear. Pre-embolisation prostate size as a predictor is controversial with a handful of papers coming to conflicting conclusions. We aimed to investigate if an association existed in our patient cohort between prostate size and clinical benefit, in addition to evaluating percentage volume reduction as a predictor of symptomatic outcome following PAE. Prospective follow-up of 86 PAE patients at a single institution between June 2012 and January 2016 was conducted (mean age 64.9 years, range 54-80 years). Multiple linear regression analysis was performed to assess strength of association between clinical improvement (change in IPSS) and other variables, of any statistical correlation, through Pearson's bivariate analysis. No major procedural complications were identified and clinical success was achieved in 72.1% (n = 62) at 12 months. Initial prostate size and percentage reduction were found to have a significant association with clinical improvement. Multiple linear regression analysis (r 2  = 0.48) demonstrated that percentage volume reduction at 3 months (r = 0.68, p < 0.001) had the strongest correlation with good symptomatic improvement at 12 months after adjusting for confounding factors. Both the initial prostate size and percentage volume reduction at 3 months predict good symptomatic outcome at 12 months. These findings therefore aid patient selection and counselling to achieve optimal outcomes for men undergoing prostate artery embolisation.

  18. Overlay accuracy on a flexible web with a roll printing process based on a roll-to-roll system.

    PubMed

    Chang, Jaehyuk; Lee, Sunggun; Lee, Ki Beom; Lee, Seungjun; Cho, Young Tae; Seo, Jungwoo; Lee, Sukwon; Jo, Gugrae; Lee, Ki-yong; Kong, Hyang-Shik; Kwon, Sin

    2015-05-01

    For high-quality flexible devices from printing processes based on Roll-to-Roll (R2R) systems, overlay alignment during the patterning of each functional layer poses a major challenge. The reason is because flexible substrates have a relatively low stiffness compared with rigid substrates, and they are easily deformed during web handling in the R2R system. To achieve a high overlay accuracy for a flexible substrate, it is important not only to develop web handling modules (such as web guiding, tension control, winding, and unwinding) and a precise printing tool but also to control the synchronization of each unit in the total system. A R2R web handling system and reverse offset printing process were developed in this work, and an overlay between the 1st and 2nd layers of ±5μm on a 500 mm-wide film was achieved at a σ level of 2.4 and 2.8 (x and y directions, respectively) in a continuous R2R printing process. This paper presents the components and mechanisms used in reverse offset printing based on a R2R system and the printing results including positioning accuracy and overlay alignment accuracy.

  19. A Tale of Two Models: Sources of Confusion in Achievement Testing. Research Report. ETS RR-17-44

    ERIC Educational Resources Information Center

    Reckase, Mark D.

    2017-01-01

    A common interpretation of achievement test results is that they provide measures of achievement that are much like other measures we commonly use for height, weight, or the cost of goods. In a limited sense, such interpretations are correct, but some nuances of these interpretations have important implications for the use of achievement test…

  20. Passive fit and accuracy of three dental implant impression techniques.

    PubMed

    Al Quran, Firas A; Rashdan, Bashar A; Zomar, AbdelRahman A Abu; Weiner, Saul

    2012-02-01

    To reassess the accuracy of three impression techniques relative to the passive fit of the prosthesis. An edentulous maxillary cast was fabricated in epoxy resin with four dental implants embedded and secured with heat-cured acrylic resin. Three techniques were tested: closed tray, open tray nonsplinted, and open tray splinted. One light-cured custom acrylic tray was fabricated for each impression technique, and transfer copings were attached to the implants. Fifteen impressions for each technique were prepared with medium-bodied consistency polyether. Subsequently, the impressions were poured in type IV die stone. The distances between the implants were measured using a digital micrometer. The statistical analysis of the data was performed with ANOVA and a one-sample t test at a 95% confidence interval. The lowest mean difference in dimensional accuracy was found within the direct (open tray) splinted technique. Also, the one-sample t test showed that the direct splinted technique has the least statistical significant difference from direct nonsplinted and indirect (closed tray) techniques. All discrepancies were less than 100 Μm. Within the limitations of this study, the best accuracy of the definitive prosthesis was achieved when the impression copings were splinted with autopolymerized acrylic resin, sectioned, and rejoined. However, the errors associated with all of these techniques were less than 100 Μm, and based on the current definitions of passive fit, they all would be clinically acceptable.

  1. Data accuracy assessment using enterprise architecture

    NASA Astrophysics Data System (ADS)

    Närman, Per; Holm, Hannes; Johnson, Pontus; König, Johan; Chenine, Moustafa; Ekstedt, Mathias

    2011-02-01

    Errors in business processes result in poor data accuracy. This article proposes an architecture analysis method which utilises ArchiMate and the Probabilistic Relational Model formalism to model and analyse data accuracy. Since the resources available for architecture analysis are usually quite scarce, the method advocates interviews as the primary data collection technique. A case study demonstrates that the method yields correct data accuracy estimates and is more resource-efficient than a competing sampling-based data accuracy estimation method.

  2. Feature Orientation and Positional Accuracy Assessment of Digital Orthophoto and Line Map for Large Scale Mapping: the Case Study on Bahir Dar Town, Ethiopia

    NASA Astrophysics Data System (ADS)

    Sisay, Z. G.; Besha, T.; Gessesse, B.

    2017-05-01

    This study used in-situ GPS data to validate the accuracy of horizontal coordinates and orientation of linear features of orthophoto and line map for Bahir Dar city. GPS data is processed using GAMIT/GLOBK and Lieca GeoOfice (LGO) in a least square sense with a tie to local and regional GPS reference stations to predict horizontal coordinates at five checkpoints. Real-Time-Kinematic GPS measurement technique is used to collect the coordinates of road centerline to test the accuracy associated with the orientation of the photogrammetric line map. The accuracy of orthophoto was evaluated by comparing with in-situ GPS coordinates and it is in a good agreement with a root mean square error (RMSE) of 12.45 cm in x- and 13.97 cm in y-coordinates, on the other hand, 6.06 cm with 95 % confidence level - GPS coordinates from GAMIT/GLOBK. Whereas, the horizontal coordinates of the orthophoto are in agreement with in-situ GPS coordinates at an accuracy of 16.71 cm and 18.98 cm in x and y-directions respectively and 11.07 cm with 95 % confidence level - GPS data is processed by LGO and a tie to local GPS network. Similarly, the accuracy of linear feature is in a good fit with in-situ GPS measurement. The GPS coordinates of the road centerline deviates from the corresponding coordinates of line map by a mean value of 9.18 cm in x- direction and -14.96 cm in y-direction. Therefore, it can be concluded that, the accuracy of the orthophoto and line map is within the national standard of error budget ( 25 cm).

  3. Increasing Efficiency and Effectiveness in Predicting Second-Grade Achievement Using a Kindergarten Screening Battery.

    ERIC Educational Resources Information Center

    Gordon, Roberta R.

    1988-01-01

    Investigation into the most effective use of a kindergarten screening battery to predict second-grade reading and mathematics achievement found that a combination of 10 readiness subtests resulted in the same degree of accuracy as that obtained using the entire battery. However, neither version was accurate enough to be useful. (Author/CB)

  4. Career Beginnings: Helping Disadvantaged Youth Achieve Their Potential. Fastback 293.

    ERIC Educational Resources Information Center

    Bloomfield, William

    Career Beginnings (CB) is a national program begun in 1985 to increase the likelihood of minority and other disadvantaged urban students to participate in postsecondary education or to obtain a good job. CB unites high schools, businesses, and local colleges in working partnerships to develop the potential of moderately-achieving high school…

  5. Dependence of Dynamic Modeling Accuracy on Sensor Measurements, Mass Properties, and Aircraft Geometry

    NASA Technical Reports Server (NTRS)

    Grauer, Jared A.; Morelli, Eugene A.

    2013-01-01

    The NASA Generic Transport Model (GTM) nonlinear simulation was used to investigate the effects of errors in sensor measurements, mass properties, and aircraft geometry on the accuracy of identified parameters in mathematical models describing the flight dynamics and determined from flight data. Measurements from a typical flight condition and system identification maneuver were systematically and progressively deteriorated by introducing noise, resolution errors, and bias errors. The data were then used to estimate nondimensional stability and control derivatives within a Monte Carlo simulation. Based on these results, recommendations are provided for maximum allowable errors in sensor measurements, mass properties, and aircraft geometry to achieve desired levels of dynamic modeling accuracy. Results using additional flight conditions and parameter estimation methods, as well as a nonlinear flight simulation of the General Dynamics F-16 aircraft, were compared with these recommendations

  6. Feasibility and accuracy of nasal alar pulse oximetry.

    PubMed

    Morey, T E; Rice, M J; Vasilopoulos, T; Dennis, D M; Melker, R J

    2014-06-01

    The nasal ala is an attractive site for pulse oximetry because of perfusion by branches of the external and internal carotid arteries. We evaluated the accuracy of a novel pulse oximetry sensor custom designed for the nasal ala. After IRB approval, healthy non-smoking subjects [n=12; aged 28 (23-41) yr; 6M/6F] breathed hypoxic mixtures of fresh gas by a facemask to achieve oxyhaemoglobin saturations of 70-100% measured by traditional co-oximetry from radial artery samples. Concurrent alar and finger pulse oximetry values were measured using probes designed for these sites. Data were analysed using the Bland-Altman method for multiple observations per subject. Bias, precision, and accuracy root mean square error (ARMS) over a range of 70-100% were significantly better for the alar probe compared with a standard finger probe. The mean bias for the alar and finger probes was 0.73% and 1.90% (P<0.001), respectively, with corresponding precision values of 1.65 and 1.83 (P=0.015) and ARMS values of 1.78% and 2.72% (P=0.047). The coefficients of determination were 0.96 and 0.96 for the alar and finger probes, respectively. The within/between-subject variation for the alar and finger probes were 1.14/1.57% and 1.87/1.47%, respectively. The limits of agreement were 3.96/-2.50% and 5.48/-1.68% for the alar and finger probes, respectively. Nasal alar pulse oximetry is feasible and demonstrates accurate pulse oximetry values over a range of 70-100%. The alar probe demonstrated greater accuracy compared with a conventional finger pulse oximeter. © The Author [2014]. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Accuracy of genomic breeding values for meat tenderness in Polled Nellore cattle.

    PubMed

    Magnabosco, C U; Lopes, F B; Fragoso, R C; Eifert, E C; Valente, B D; Rosa, G J M; Sainz, R D

    2016-07-01

    .22 (Bayes Cπ) to 0.25 (Bayes B). When preselecting SNP based on GWAS results, the highest correlation (0.27) between WBSF and the genomic breeding value was achieved using the Bayesian LASSO model with 15,030 (3%) markers. Although this study used relatively few animals, the design of the segregating population ensured wide genetic variability for meat tenderness, which was important to achieve acceptable accuracy of genomic prediction. Although all models showed similar levels of prediction accuracy, some small advantages were observed with the Bayes B approach when higher numbers of markers were preselected based on their -values resulting from a GWAS analysis.

  8. Smart Device-Supported BDS/GNSS Real-Time Kinematic Positioning for Sub-Meter-Level Accuracy in Urban Location-Based Services.

    PubMed

    Wang, Liang; Li, Zishen; Zhao, Jiaojiao; Zhou, Kai; Wang, Zhiyu; Yuan, Hong

    2016-12-21

    Using mobile smart devices to provide urban location-based services (LBS) with sub-meter-level accuracy (around 0.5 m) is a major application field for future global navigation satellite system (GNSS) development. Real-time kinematic (RTK) positioning, which is a widely used GNSS-based positioning approach, can improve the accuracy from about 10-20 m (achieved by the standard positioning services) to about 3-5 cm based on the geodetic receivers. In using the smart devices to achieve positioning with sub-meter-level accuracy, a feasible solution of combining the low-cost GNSS module and the smart device is proposed in this work and a user-side GNSS RTK positioning software was developed from scratch based on the Android platform. Its real-time positioning performance was validated by BeiDou Navigation Satellite System/Global Positioning System (BDS/GPS) combined RTK positioning under the conditions of a static and kinematic (the velocity of the rover was 50-80 km/h) mode in a real urban environment with a SAMSUNG Galaxy A7 smartphone. The results show that the fixed-rates of ambiguity resolution (the proportion of epochs of ambiguities fixed) for BDS/GPS combined RTK in the static and kinematic tests were about 97% and 90%, respectively, and the average positioning accuracies (RMS) were better than 0.15 m (horizontal) and 0.25 m (vertical) for the static test, and 0.30 m (horizontal) and 0.45 m (vertical) for the kinematic test.

  9. Benchmark Campaign of the COST Action GNSS4SWEC: Main Goals and Achievements

    NASA Astrophysics Data System (ADS)

    Dick, G.; Dousa, J.; Kacmarik, M.; Pottiaux, E.; Zus, F.; Brenot, H. H.; Moeller, G.; Kaplon, J.; Morel, L.; Hordyniec, P.

    2016-12-01

    This talk will give an overview of achievements of the Benchmark campaign, one of the central activities in the framework of the COST Action ES 1206 GNSS4SWEC. The main goal of the campaign is supporting the development and validation of advanced Global Navigation Satellite System (GNSS) tropospheric products, in particular high-resolution and ultra-fast/real-time zenith total delays (ZTD) and asymmetry products in terms of tropospheric horizontal gradients and slant delays.For the Benchmark campaign a complex data set of GNSS observations and various meteorological data were collected for a two-month period in 2013 (May-June) which included severe weather events in central Europe. An initial processing of data sets from GNSS and numerical weather models (NWM) provided independently estimated tropospheric reference products - ZTDs, tropospheric horizontal gradients and others. The comparison of horizontal tropospheric gradients from GNSS and NWM data demonstrated a very good agreement among independent solutions with negligible biases and an accuracy of about 0.5 mm. Visual comparisons of maps of zenith wet delays and tropospheric horizontal gradients showed very promising results for future exploitations of advanced GNSS tropospheric products in meteorological applications such as severe weather event monitoring and weather nowcasting.The benchmark data set is also used for an extensive validation of line-of-sight tropospheric Slant Total Delays (STD) from GNSS, NWM-raytracing and Water Vapour Radiometer (WVR) solutions. Six institutions delivered their STDs based on GNSS observations processed using different software and strategies. STDs from NWM ray-tracing came from three institutions using three different NWM models. Results show generally a very good mutual agreement among all solutions from all techniques. Among all an influence of adding not cleaned as well as cleaned GNSS post-fit residuals, i.e. residuals with eliminated and not eliminated non

  10. Accuracy of nursing diagnosis "readiness for enhanced hope" in patients with chronic kidney disease.

    PubMed

    Silva, Renan Alves; Melo, Geórgia Alcântara Alencar; Caetano, Joselany Áfio; Lopes, Marcos Venícios Oliveira; Butcher, Howard Karl; Silva, Viviane Martins da

    2017-07-06

    To analyse the accuracy of the nursing diagnosis readiness for enhanced hope in patients with chronic kidney disease. This is a cross-sectional study with 62 patients in the haemodialysis clinic conducted from August to November 2015. The Hearth Hope Scale was used to create definitions of the defining characteristics of the North American Nursing Diagnosis Association International. We analysed the measures of sensitivity, specificity, predictive value, likelihood ratio, and odds ratio of the defining characteristics of the diagnosis. Of the characteristics, 82.22% presented the diagnosis. The defining characteristics "Expresses the desire to enhance congruency of expectations with desires" and "Expresses the desire to enhance problem solving to meet goals" increased the chance of having the diagnosis by eleven and five, respectively. The characteristics, "Expresses desire to enhance congruency of expectations with desires" and "Expresses desire to enhance problem solving to meet goals" had good accuracy measures.

  11. Obtaining identical results with double precision global accuracy on different numbers of processors in parallel particle Monte Carlo simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cleveland, Mathew A., E-mail: cleveland7@llnl.gov; Brunner, Thomas A.; Gentile, Nicholas A.

    2013-10-15

    We describe and compare different approaches for achieving numerical reproducibility in photon Monte Carlo simulations. Reproducibility is desirable for code verification, testing, and debugging. Parallelism creates a unique problem for achieving reproducibility in Monte Carlo simulations because it changes the order in which values are summed. This is a numerical problem because double precision arithmetic is not associative. Parallel Monte Carlo, both domain replicated and decomposed simulations, will run their particles in a different order during different runs of the same simulation because the non-reproducibility of communication between processors. In addition, runs of the same simulation using different domain decompositionsmore » will also result in particles being simulated in a different order. In [1], a way of eliminating non-associative accumulations using integer tallies was described. This approach successfully achieves reproducibility at the cost of lost accuracy by rounding double precision numbers to fewer significant digits. This integer approach, and other extended and reduced precision reproducibility techniques, are described and compared in this work. Increased precision alone is not enough to ensure reproducibility of photon Monte Carlo simulations. Non-arbitrary precision approaches require a varying degree of rounding to achieve reproducibility. For the problems investigated in this work double precision global accuracy was achievable by using 100 bits of precision or greater on all unordered sums which where subsequently rounded to double precision at the end of every time-step.« less

  12. Increased genomic prediction accuracy in wheat breeding using a large Australian panel.

    PubMed

    Norman, Adam; Taylor, Julian; Tanaka, Emi; Telfer, Paul; Edwards, James; Martinant, Jean-Pierre; Kuchel, Haydn

    2017-12-01

    Genomic prediction accuracy within a large panel was found to be substantially higher than that previously observed in smaller populations, and also higher than QTL-based prediction. In recent years, genomic selection for wheat breeding has been widely studied, but this has typically been restricted to population sizes under 1000 individuals. To assess its efficacy in germplasm representative of commercial breeding programmes, we used a panel of 10,375 Australian wheat breeding lines to investigate the accuracy of genomic prediction for grain yield, physical grain quality and other physiological traits. To achieve this, the complete panel was phenotyped in a dedicated field trial and genotyped using a custom Axiom TM Affymetrix SNP array. A high-quality consensus map was also constructed, allowing the linkage disequilibrium present in the germplasm to be investigated. Using the complete SNP array, genomic prediction accuracies were found to be substantially higher than those previously observed in smaller populations and also more accurate compared to prediction approaches using a finite number of selected quantitative trait loci. Multi-trait genetic correlations were also assessed at an additive and residual genetic level, identifying a negative genetic correlation between grain yield and protein as well as a positive genetic correlation between grain size and test weight.

  13. The Effectiveness of the SSHA in Improving Prediction of Academic Achievement.

    ERIC Educational Resources Information Center

    Wikoff, Richard L.; Kafka, Gene F.

    1981-01-01

    Investigated the effectiveness of the Survey of Study Habits (SSHA) in improving prediction of achievement. The American College Testing Program English and mathematics subtests were good predictors of gradepoint average. The SSHA subtests accounted for an additional 3 percent of the variance. Sex differences were noted. (Author)

  14. Comparison of inversion accuracy of soil copper content from vegetation indices under different spectral resolution

    NASA Astrophysics Data System (ADS)

    Sun, Zhongqing; Shang, Kun; Jia, Lingjun

    2018-03-01

    Remote sensing inversion of heavy metal in vegetation leaves is generally based on the physiological characteristics of vegetation spectrum under heavy metal stress, and empirical models with vegetation indices are established to inverse the heavy metal content of vegetation leaves. However, the research of inversion of heavy metal content in vegetation-covered soil is still rare. In this study, Pulang is chosen as study area. The regression model of a typical heavy metal element, copper (Cu), is established with vegetation indices. We mainly investigate the inversion accuracies of Cu element in vegetation-covered soil by different vegetation indices according to specific spectral resolutions of ASD (Analytical Spectral Device) and Hyperion data. The inversion results of soil copper content in the vegetation-covered area shows a good accuracy, and the vegetation indices under ASD spectral resolution correspond to better results.

  15. Improvement of Dimensional Accuracy of 3-D Printed Parts using an Additive/Subtractive Based Hybrid Prototyping Approach

    NASA Astrophysics Data System (ADS)

    Amanullah Tomal, A. N. M.; Saleh, Tanveer; Raisuddin Khan, Md.

    2017-11-01

    At present, two important processes, namely CNC machining and rapid prototyping (RP) are being used to create prototypes and functional products. Combining both additive and subtractive processes into a single platform would be advantageous. However, there are two important aspects need to be taken into consideration for this process hybridization. First is the integration of two different control systems for two processes and secondly maximizing workpiece alignment accuracy during the changeover step. Recently we have developed a new hybrid system which incorporates Fused Deposition Modelling (FDM) as RP Process and CNC grinding operation as subtractive manufacturing process into a single setup. Several objects were produced with different layer thickness for example 0.1 mm, 0.15 mm and 0.2 mm. It was observed that pure FDM method is unable to attain desired dimensional accuracy and can be improved by a considerable margin about 66% to 80%, if finishing operation by grinding is carried out. It was also observed layer thickness plays a role on the dimensional accuracy and best accuracy is achieved with the minimum layer thickness (0.1 mm).

  16. Speed-Accuracy Trade-Off in a Trajectory-Constrained Self-Feeding Task: A Quantitative Index of Unsuppressed Motor Noise in Children With Dystonia.

    PubMed

    Lunardini, Francesca; Bertucco, Matteo; Casellato, Claudia; Bhanpuri, Nasir; Pedrocchi, Alessandra; Sanger, Terence D

    2015-10-01

    Motor speed and accuracy are both affected in childhood dystonia. Thus, deriving a speed-accuracy function is an important metric for assessing motor impairments in dystonia. Previous work in dystonia studied the speed-accuracy trade-off during point-to-point tasks. To achieve a more relevant measurement of functional abilities in dystonia, the present study investigates upper-limb kinematics and electromyographic activity of 8 children with dystonia and 8 healthy children during a trajectory-constrained child-relevant task that emulates self-feeding with a spoon and requires continuous monitoring of accuracy. The speed-accuracy trade-off is examined by changing the spoon size to create different accuracy demands. Results demonstrate that the trajectory-constrained speed-accuracy relation is present in both groups, but it is altered in dystonia in terms of increased slope and offset toward longer movement times. Findings are consistent with the hypothesis of increased signal-dependent noise in dystonia, which may partially explain the slow and variable movements observed in dystonia. © The Author(s) 2015.

  17. The Relationship Between Eyewitness Confidence and Identification Accuracy: A New Synthesis.

    PubMed

    Wixted, John T; Wells, Gary L

    2017-05-01

    The U.S. legal system increasingly accepts the idea that the confidence expressed by an eyewitness who identified a suspect from a lineup provides little information as to the accuracy of that identification. There was a time when this pessimistic assessment was entirely reasonable because of the questionable eyewitness-identification procedures that police commonly employed. However, after more than 30 years of eyewitness-identification research, our understanding of how to properly conduct a lineup has evolved considerably, and the time seems ripe to ask how eyewitness confidence informs accuracy under more pristine testing conditions (e.g., initial, uncontaminated memory tests using fair lineups, with no lineup administrator influence, and with an immediate confidence statement). Under those conditions, mock-crime studies and police department field studies have consistently shown that, for adults, (a) confidence and accuracy are strongly related and (b) high-confidence suspect identifications are remarkably accurate. However, when certain non-pristine testing conditions prevail (e.g., when unfair lineups are used), the accuracy of even a high-confidence suspect ID is seriously compromised. Unfortunately, some jurisdictions have not yet made reforms that would create pristine testing conditions and, hence, our conclusions about the reliability of high-confidence identifications cannot yet be applied to those jurisdictions. However, understanding the information value of eyewitness confidence under pristine testing conditions can help the criminal justice system to simultaneously achieve both of its main objectives: to exonerate the innocent (by better appreciating that initial, low-confidence suspect identifications are error prone) and to convict the guilty (by better appreciating that initial, high-confidence suspect identifications are surprisingly accurate under proper testing conditions).

  18. Accuracy of Genomic Prediction in Switchgrass (Panicum virgatum L.) Improved by Accounting for Linkage Disequilibrium

    PubMed Central

    Ramstein, Guillaume P.; Evans, Joseph; Kaeppler, Shawn M.; Mitchell, Robert B.; Vogel, Kenneth P.; Buell, C. Robin; Casler, Michael D.

    2016-01-01

    Switchgrass is a relatively high-yielding and environmentally sustainable biomass crop, but further genetic gains in biomass yield must be achieved to make it an economically viable bioenergy feedstock. Genomic selection (GS) is an attractive technology to generate rapid genetic gains in switchgrass, and meet the goals of a substantial displacement of petroleum use with biofuels in the near future. In this study, we empirically assessed prediction procedures for genomic selection in two different populations, consisting of 137 and 110 half-sib families of switchgrass, tested in two locations in the United States for three agronomic traits: dry matter yield, plant height, and heading date. Marker data were produced for the families’ parents by exome capture sequencing, generating up to 141,030 polymorphic markers with available genomic-location and annotation information. We evaluated prediction procedures that varied not only by learning schemes and prediction models, but also by the way the data were preprocessed to account for redundancy in marker information. More complex genomic prediction procedures were generally not significantly more accurate than the simplest procedure, likely due to limited population sizes. Nevertheless, a highly significant gain in prediction accuracy was achieved by transforming the marker data through a marker correlation matrix. Our results suggest that marker-data transformations and, more generally, the account of linkage disequilibrium among markers, offer valuable opportunities for improving prediction procedures in GS. Some of the achieved prediction accuracies should motivate implementation of GS in switchgrass breeding programs. PMID:26869619

  19. Laser ranging with the MéO telescope to improve orbital accuracy of space debris

    NASA Astrophysics Data System (ADS)

    Hennegrave, L.; Pyanet, M.; Haag, H.; Blanchet, G.; Esmiller, B.; Vial, S.; Samain, E.; Paris, J.; Albanese, D.

    2013-05-01

    Improving orbital accuracy of space debris is one of the major prerequisite to performing reliable collision prediction in low earth orbit. The objective is to avoid false alarms and useless maneuvers for operational satellites. This paper shows how laser ranging on debris can improve the accuracy of orbit determination. In March 2012 a joint OCA-Astrium team had the first laser echoes from space debris using the MéO (Métrologie Optique) telescope of the Observatoire de la Côte d'Azur (OCA), upgraded with a nanosecond pulsed laser. The experiment was conducted in full compliance with the procedures dictated by the French Civil Aviation Authorities. To perform laser ranging measurement on space debris, the laser link budget needed to be improved. Related technical developments were supported by implementation of a 2J pulsed laser purchased by ASTRIUM and an adapted photo detection. To achieve acquisition of the target from low accuracy orbital data such as Two Lines Elements, a 2.3-degree field of view telescope was coupled to the original MéO telescope 3-arcmin narrow field of view. The wide field of view telescope aimed at pointing, adjusting and acquiring images of the space debris for astrometry measurement. The achieved set-up allowed performing laser ranging and angular measurements in parallel, on several rocket stages from past launches. After a brief description of the set-up, development issues and campaigns, the paper discusses added-value of laser ranging measurement when combined to angular measurement for accurate orbit determination. Comparison between different sets of experimental results as well as simulation results is given.

  20. Dimensional accuracy of aluminium extrusions in mechanical calibration

    NASA Astrophysics Data System (ADS)

    Raknes, Christian Arne; Welo, Torgeir; Paulsen, Frode

    2018-05-01

    Reducing dimensional variations in the extrusion process without increasing cost is challenging due to the nature of the process itself. An alternative approach—also from a cost perspective—is using extruded profiles with standard tolerances and utilize downstream processes, and thus calibrate the part within tolerance limits that are not achievable directly from the extrusion process. In this paper, two mechanical calibration strategies for the extruded product are investigated, utilizing the forming lines of the manufacturer. The first calibration strategy is based on global, longitudinal stretching in combination with local bending, while the second strategy utilizes the principle of transversal stretching and local bending of the cross-section. An extruded U-profile is used to make a comparison between the two methods using numerical analyses. To provide response surfaces with the FEA program, ABAQUS is used in combination with Design of Experiment (DOE). DOE is conducted with a two-level fractional factorial design to collect the appropriate data. The aim is to find the main factors affecting the dimension accuracy of the final part obtained by the two calibration methods. The results show that both calibration strategies have proven to reduce cross-sectional variations effectively form standard extrusion tolerances. It is concluded that mechanical calibration is a viable, low-cost alternative for aluminium parts that demand high dimensional accuracy, e.g. due to fit-up or welding requirements.

  1. On the Accuracy Potential in Underwater/Multimedia Photogrammetry

    PubMed Central

    Maas, Hans-Gerd

    2015-01-01

    Underwater applications of photogrammetric measurement techniques usually need to deal with multimedia photogrammetry aspects, which are characterized by the necessity of handling optical rays that are refracted at interfaces between optical media with different refractive indices according to Snell’s Law. This so-called multimedia geometry has to be incorporated into geometric models in order to achieve correct measurement results. The paper shows a flexible yet strict geometric model for the handling of refraction effects on the optical path, which can be implemented as a module into photogrammetric standard tools such as spatial resection, spatial intersection, bundle adjustment or epipolar line computation. The module is especially well suited for applications, where an object in water is observed by cameras in air through one or more planar glass interfaces, as it allows for some simplifications here. In the second part of the paper, several aspects, which are relevant for an assessment of the accuracy potential in underwater/multimedia photogrammetry, are discussed. These aspects include network geometry and interface planarity issues as well as effects caused by refractive index variations and dispersion and diffusion under water. All these factors contribute to a rather significant degradation of the geometric accuracy potential in underwater/multimedia photogrammetry. In practical experiments, a degradation of the quality of results by a factor two could be determined under relatively favorable conditions. PMID:26213942

  2. Climate Change Observation Accuracy: Requirements and Economic Value

    NASA Technical Reports Server (NTRS)

    Wielicki, Bruce; Cooke, Roger; Golub, Alexander; Baize, Rosemary; Mlynczak, Martin; Lukashin, Constantin; Thome, Kurt; Shea, Yolanda; Kopp, Greg; Pilewskie, Peter; hide

    2016-01-01

    This presentation will summarize a new quantitative approach to determining the required accuracy for climate change observations. Using this metric, most current global satellite observations struggle to meet this accuracy level. CLARREO (Climate Absolute Radiance and Refractivity Observatory) is a new satellite mission designed to resolve this challenge is by achieving advances of a factor of 10 for reflected solar spectra and a factor of 3 to 5 for thermal infrared spectra. The CLARREO spectrometers can serve as SI traceable benchmarks for the Global Satellite Intercalibration System (GSICS) and greatly improve the utility of a wide range of LEO and GEO infrared and reflected solar satellite sensors for climate change observations (e.g. CERES, MODIS, VIIIRS, CrIS, IASI, Landsat, etc). A CLARREO Pathfinder mission for flight on the International Space Station is included in the U.S. Presidentâ€"TM"s fiscal year 2016 budget, with launch in 2019 or 2020. Providing more accurate decadal change trends can in turn lead to more rapid narrowing of key climate science uncertainties such as cloud feedback and climate sensitivity. A new study has been carried out to quantify the economic benefits of such an advance and concludes that the economic value is $9 Trillion U.S. dollars. The new value includes the cost of carbon emissions reductions.

  3. On the Accuracy Potential in Underwater/Multimedia Photogrammetry.

    PubMed

    Maas, Hans-Gerd

    2015-07-24

    Underwater applications of photogrammetric measurement techniques usually need to deal with multimedia photogrammetry aspects, which are characterized by the necessity of handling optical rays that are refracted at interfaces between optical media with different refractive indices according to Snell's Law. This so-called multimedia geometry has to be incorporated into geometric models in order to achieve correct measurement results. The paper shows a flexible yet strict geometric model for the handling of refraction effects on the optical path, which can be implemented as a module into photogrammetric standard tools such as spatial resection, spatial intersection, bundle adjustment or epipolar line computation. The module is especially well suited for applications, where an object in water is observed by cameras in air through one or more planar glass interfaces, as it allows for some simplifications here. In the second part of the paper, several aspects, which are relevant for an assessment of the accuracy potential in underwater/multimedia photogrammetry, are discussed. These aspects include network geometry and interface planarity issues as well as effects caused by refractive index variations and dispersion and diffusion under water. All these factors contribute to a rather significant degradation of the geometric accuracy potential in underwater/multimedia photogrammetry. In practical experiments, a degradation of the quality of results by a factor two could be determined under relatively favorable conditions.

  4. Accuracy of Monte Carlo simulations compared to in-vivo MDCT dosimetry.

    PubMed

    Bostani, Maryam; Mueller, Jonathon W; McMillan, Kyle; Cody, Dianna D; Cagnon, Chris H; DeMarco, John J; McNitt-Gray, Michael F

    2015-02-01

    The purpose of this study was to assess the accuracy of a Monte Carlo simulation-based method for estimating radiation dose from multidetector computed tomography (MDCT) by comparing simulated doses in ten patients to in-vivo dose measurements. MD Anderson Cancer Center Institutional Review Board approved the acquisition of in-vivo rectal dose measurements in a pilot study of ten patients undergoing virtual colonoscopy. The dose measurements were obtained by affixing TLD capsules to the inner lumen of rectal catheters. Voxelized patient models were generated from the MDCT images of the ten patients, and the dose to the TLD for all exposures was estimated using Monte Carlo based simulations. The Monte Carlo simulation results were compared to the in-vivo dose measurements to determine accuracy. The calculated mean percent difference between TLD measurements and Monte Carlo simulations was -4.9% with standard deviation of 8.7% and a range of -22.7% to 5.7%. The results of this study demonstrate very good agreement between simulated and measured doses in-vivo. Taken together with previous validation efforts, this work demonstrates that the Monte Carlo simulation methods can provide accurate estimates of radiation dose in patients undergoing CT examinations.

  5. Accuracy of volumetric measurement of simulated root resorption lacunas based on cone beam computed tomography.

    PubMed

    Wang, Y; He, S; Guo, Y; Wang, S; Chen, S

    2013-08-01

    To evaluate the accuracy of volumetric measurement of simulated root resorption cavities based on cone beam computed tomography (CBCT), in comparison with that of Micro-computed tomography (Micro-CT) which served as the reference. The State Key Laboratory of Oral Diseases at Sichuan University. Thirty-two bovine teeth were included for standardized CBCT scanning and Micro-CT scanning before and after the simulation of different degrees of root resorption. The teeth were divided into three groups according to the depths of the root resorption cavity (group 1: 0.15, 0.2, 0.3 mm; group 2: 0.6, 1.0 mm; group 3: 1.5, 2.0, 3.0 mm). Each depth included four specimens. Differences in tooth volume before and after simulated root resorption were then calculated from CBCT and Micro-CT scans, respectively. The overall between-method agreement of the measurements was evaluated using the concordance correlation coefficient (CCC). For the first group, the average volume of resorption cavity was 1.07 mm(3) , and the between-method agreement of measurement for the volume changes was low (CCC = 0.098). For the second and third groups, the average volumes of resorption cavities were 3.47 and 6.73 mm(3) respectively, and the between-method agreements were good (CCC = 0.828 and 0.895, respectively). The accuracy of 3-D quantitative volumetric measurement of simulated root resorption based on CBCT was fairly good in detecting simulated resorption cavities larger than 3.47 mm(3), while it was not sufficient for measuring resorption cavities smaller than 1.07 mm(3) . This method could be applied in future studies of root resorption although further studies are required to improve its accuracy. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Recall accuracy of mobile phone calls among Japanese young people.

    PubMed

    Kiyohara, Kosuke; Wake, Kanako; Watanabe, Soichi; Arima, Takuji; Sato, Yasuto; Kojimahara, Noriko; Taki, Masao; Yamaguchi, Naohito

    2016-11-01

    This study aimed to elucidate the recall accuracy of mobile phone calls among young people using new software-modified phone (SMP) technology. A total of 198 Japanese students aged between 10 and 24 years were instructed to use a SMP for 1 month to record their actual call statuses. Ten to 12 months after this period, face-to-face interviews were conducted to obtain the self-reported call statuses during the monitoring period. Using the SMP record as the gold standard of validation, the recall accuracy of phone calls was evaluated. A total of 19% of the participants (34/177) misclassified their laterality (i.e., the dominant side of ear used while making calls), with the level of agreement being moderate (κ-statistics, 0.449). The level of agreement between the self-reports and SMP records was relatively good for the duration of calls (Pearson's r, 0.620), as compared with the number of calls (Pearson's r, 0.561). The recall was prone to small systematic and large random errors for both the number and duration of calls. Such a large random recall error for the amount of calls and misclassification of laterality suggest that the results of epidemiological studies of mobile phone use based on self-assessment should be interpreted cautiously.

  7. From Great to Good: Principals' Sensemaking of Student Performance Decline in Formerly High Achieving High Poverty Schools

    ERIC Educational Resources Information Center

    Darbonne, Deborah

    2016-01-01

    School level leadership is second only to effective instruction as essential to high student achievement (Leithwood, Louis, Anderson & Wahlstrom, 2004). Although factors such as socioeconomic levels and parental involvement contribute to the academic success of students, school leadership outweighs the impact of those factors. In the era of…

  8. Mister Sandman, bring me good marks! On the relationship between sleep quality and academic achievement.

    PubMed

    Baert, Stijn; Omey, Eddy; Verhaest, Dieter; Vermeir, Aurélie

    2015-04-01

    There is growing evidence that health factors affect tertiary education success in a causal way. This study assesses the effect of sleep quality on academic achievement at university. To this end, we surveyed 804 students about their sleep quality by means of the Pittsburgh Sleep Quality Index (PSQI) before the start of their first exam period in December 2013 at Ghent University. PSQI scores were merged with course marks in this exam period. Instrumenting PSQI scores by sleep quality during secondary education, we find that increasing total sleep quality with one standard deviation leads to 4.85 percentage point higher course marks. Based on this finding, we suggest that higher education providers might be incentivised to invest part of their resources for social facilities in professional support for students with sleep and other health problems. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Influence of stimulated Brillouin scattering on positioning accuracy of long-range dual Mach-Zehnder interferometric vibration sensors

    NASA Astrophysics Data System (ADS)

    He, Xiangge; Xie, Shangran; Cao, Shan; Liu, Fei; Zheng, Xiaoping; Zhang, Min; Yan, Han; Chen, Guocai

    2016-11-01

    The properties of noise induced by stimulated Brillouin scattering (SBS) in long-range interferometers and their influences on the positioning accuracy of dual Mach-Zehnder interferometric (DMZI) vibration sensing systems are studied. The SBS noise is found to be white and incoherent between the two arms of the interferometer in a 1-MHz bandwidth range. Experiments on 25-km long fibers show that the root mean square error (RMSE) of the positioning accuracy is consistent with the additive noise model for the time delay estimation theory. A low-pass filter can be properly designed to suppress the SBS noise and further achieve a maximum RMSE reduction of 6.7 dB.

  10. Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty.

    PubMed

    Rosenberger, Ralf E; Hoser, Christian; Quirbach, Sebastian; Attal, Rene; Hennerbichler, Alfred; Fink, Christian

    2008-03-01

    Accuracy of implant positioning and reconstruction of the mechanical leg axis are major requirements for achieving good long-term results in total knee arthroplasty (TKA). The purpose of the present study was to determine whether image-free computer navigation technology has the potential to improve the accuracy of component alignment in TKA cohorts of experienced surgeons immediately and constantly. One hundred patients with primary arthritis of the knee underwent the unilateral total knee arthroplasty. The cohort of 50 TKAs implanted with conventional instrumentation was directly followed by the cohort of the very first 50 computer-assisted TKAs. All surgeries were performed by two senior surgeons. All patients received the Zimmer NexGen total knee prosthesis (Zimmer Inc., Warsaw, IN, USA). There was no variability regarding surgeons or surgical technique, except for the use of the navigation system (StealthStation) Treon plus Medtronic Inc., Minnesota, MI, USA). Accuracy of implant positioning was measured on postoperative long-leg standing radiographs and standard lateral X-rays with regard to the valgus angle and the coronal and sagittal component angles. In addition, preoperative deformities of the mechanical leg axis, tourniquet time, age, and gender were correlated. Statistical analyses were performed using the SPSS 15.0 (SPSS Inc., Chicago, IL, USA) software package. Independent t-tests were used, with significance set at P < 0.05 (two-tailed) to compare differences in mean angular values and frontal mechanical alignment between the two cohorts. To compute the rate of optimally implanted prostheses between the two groups we used the chi(2) test. The average postoperative radiological frontal mechanical alignment was 1.88 degrees of varus (range 6.1 degrees of valgus-10.1 degrees of varus; SD 3.68 degrees ) in the conventional cohort and 0.28 degrees of varus (range 3.7 degrees -6.0 degrees of varus; SD 1.97 degrees ) in the navigated cohort. Including all

  11. Improving LUC estimation accuracy with multiple classification system for studying impact of urbanization on watershed flood

    NASA Astrophysics Data System (ADS)

    Dou, P.

    2017-12-01

    Guangzhou has experienced a rapid urbanization period called "small change in three years and big change in five years" since the reform of China, resulting in significant land use/cover changes(LUC). To overcome the disadvantages of single classifier for remote sensing image classification accuracy, a multiple classifier system (MCS) is proposed to improve the quality of remote sensing image classification. The new method combines advantages of different learning algorithms, and achieves higher accuracy (88.12%) than any single classifier did. With the proposed MCS, land use/cover (LUC) on Landsat images from 1987 to 2015 was obtained, and the LUCs were used on three watersheds (Shijing river, Chebei stream, and Shahe stream) to estimate the impact of urbanization on water flood. The results show that with the high accuracy LUC, the uncertainty in flood simulations are reduced effectively (for Shijing river, Chebei stream, and Shahe stream, the uncertainty reduced 15.5%, 17.3% and 19.8% respectively).

  12. Optimizing Tsunami Forecast Model Accuracy

    NASA Astrophysics Data System (ADS)

    Whitmore, P.; Nyland, D. L.; Huang, P. Y.

    2015-12-01

    Recent tsunamis provide a means to determine the accuracy that can be expected of real-time tsunami forecast models. Forecast accuracy using two different tsunami forecast models are compared for seven events since 2006 based on both real-time application and optimized, after-the-fact "forecasts". Lessons learned by comparing the forecast accuracy determined during an event to modified applications of the models after-the-fact provide improved methods for real-time forecasting for future events. Variables such as source definition, data assimilation, and model scaling factors are examined to optimize forecast accuracy. Forecast accuracy is also compared for direct forward modeling based on earthquake source parameters versus accuracy obtained by assimilating sea level data into the forecast model. Results show that including assimilated sea level data into the models increases accuracy by approximately 15% for the events examined.

  13. Influence of Spatial Resolution in Three-dimensional Cine Phase Contrast Magnetic Resonance Imaging on the Accuracy of Hemodynamic Analysis

    PubMed Central

    Fukuyama, Atsushi; Isoda, Haruo; Morita, Kento; Mori, Marika; Watanabe, Tomoya; Ishiguro, Kenta; Komori, Yoshiaki; Kosugi, Takafumi

    2017-01-01

    Introduction: We aim to elucidate the effect of spatial resolution of three-dimensional cine phase contrast magnetic resonance (3D cine PC MR) imaging on the accuracy of the blood flow analysis, and examine the optimal setting for spatial resolution using flow phantoms. Materials and Methods: The flow phantom has five types of acrylic pipes that represent human blood vessels (inner diameters: 15, 12, 9, 6, and 3 mm). The pipes were fixed with 1% agarose containing 0.025 mol/L gadolinium contrast agent. A blood-mimicking fluid with human blood property values was circulated through the pipes at a steady flow. Magnetic resonance (MR) images (three-directional phase images with speed information and magnitude images for information of shape) were acquired using the 3-Tesla MR system and receiving coil. Temporal changes in spatially-averaged velocity and maximum velocity were calculated using hemodynamic analysis software. We calculated the error rates of the flow velocities based on the volume flow rates measured with a flowmeter and examined measurement accuracy. Results: When the acrylic pipe was the size of the thoracicoabdominal or cervical artery and the ratio of pixel size for the pipe was set at 30% or lower, spatially-averaged velocity measurements were highly accurate. When the pixel size ratio was set at 10% or lower, maximum velocity could be measured with high accuracy. It was difficult to accurately measure maximum velocity of the 3-mm pipe, which was the size of an intracranial major artery, but the error for spatially-averaged velocity was 20% or less. Conclusions: Flow velocity measurement accuracy of 3D cine PC MR imaging for pipes with inner sizes equivalent to vessels in the cervical and thoracicoabdominal arteries is good. The flow velocity accuracy for the pipe with a 3-mm-diameter that is equivalent to major intracranial arteries is poor for maximum velocity, but it is relatively good for spatially-averaged velocity. PMID:28132996

  14. TIMSS 2011 Student and Teacher Predictors for Mathematics Achievement Explored and Identified via Elastic Net.

    PubMed

    Yoo, Jin Eun

    2018-01-01

    A substantial body of research has been conducted on variables relating to students' mathematics achievement with TIMSS. However, most studies have employed conventional statistical methods, and have focused on selected few indicators instead of utilizing hundreds of variables TIMSS provides. This study aimed to find a prediction model for students' mathematics achievement using as many TIMSS student and teacher variables as possible. Elastic net, the selected machine learning technique in this study, takes advantage of both LASSO and ridge in terms of variable selection and multicollinearity, respectively. A logistic regression model was also employed to predict TIMSS 2011 Korean 4th graders' mathematics achievement. Ten-fold cross-validation with mean squared error was employed to determine the elastic net regularization parameter. Among 162 TIMSS variables explored, 12 student and 5 teacher variables were selected in the elastic net model, and the prediction accuracy, sensitivity, and specificity were 76.06, 70.23, and 80.34%, respectively. This study showed that the elastic net method can be successfully applied to educational large-scale data by selecting a subset of variables with reasonable prediction accuracy and finding new variables to predict students' mathematics achievement. Newly found variables via machine learning can shed light on the existing theories from a totally different perspective, which in turn propagates creation of a new theory or complement of existing ones. This study also examined the current scale development convention from a machine learning perspective.

  15. TIMSS 2011 Student and Teacher Predictors for Mathematics Achievement Explored and Identified via Elastic Net

    PubMed Central

    Yoo, Jin Eun

    2018-01-01

    A substantial body of research has been conducted on variables relating to students' mathematics achievement with TIMSS. However, most studies have employed conventional statistical methods, and have focused on selected few indicators instead of utilizing hundreds of variables TIMSS provides. This study aimed to find a prediction model for students' mathematics achievement using as many TIMSS student and teacher variables as possible. Elastic net, the selected machine learning technique in this study, takes advantage of both LASSO and ridge in terms of variable selection and multicollinearity, respectively. A logistic regression model was also employed to predict TIMSS 2011 Korean 4th graders' mathematics achievement. Ten-fold cross-validation with mean squared error was employed to determine the elastic net regularization parameter. Among 162 TIMSS variables explored, 12 student and 5 teacher variables were selected in the elastic net model, and the prediction accuracy, sensitivity, and specificity were 76.06, 70.23, and 80.34%, respectively. This study showed that the elastic net method can be successfully applied to educational large-scale data by selecting a subset of variables with reasonable prediction accuracy and finding new variables to predict students' mathematics achievement. Newly found variables via machine learning can shed light on the existing theories from a totally different perspective, which in turn propagates creation of a new theory or complement of existing ones. This study also examined the current scale development convention from a machine learning perspective. PMID:29599736

  16. Accuracy of Two Motor Assessments during the First Year of Life in Preterm Infants for Predicting Motor Outcome at Preschool Age

    PubMed Central

    Spittle, Alicia J.; Lee, Katherine J.; Spencer-Smith, Megan; Lorefice, Lucy E.; Anderson, Peter J.; Doyle, Lex W.

    2015-01-01

    Aim The primary aim of this study was to investigate the accuracy of the Alberta Infant Motor Scale (AIMS) and Neuro-Sensory Motor Developmental Assessment (NSMDA) over the first year of life for predicting motor impairment at 4 years in preterm children. The secondary aims were to assess the predictive value of serial assessments over the first year and when using a combination of these two assessment tools in follow-up. Method Children born <30 weeks’ gestation were prospectively recruited and assessed at 4, 8 and 12 months’ corrected age using the AIMS and NSMDA. At 4 years’ corrected age children were assessed for cerebral palsy (CP) and motor impairment using the Movement Assessment Battery for Children 2nd-edition (MABC-2). We calculated accuracy of the AIMS and NSMDA for predicting CP and MABC-2 scores ≤15th (at-risk of motor difficulty) and ≤5th centile (significant motor difficulty) for each test (AIMS and NSMDA) at 4, 8 and 12 months, for delay on one, two or all three of the time points over the first year, and finally for delay on both tests at each time point. Results Accuracy for predicting motor impairment was good for each test at each age, although false positives were common. Motor impairment on the MABC-2 (scores ≤5th and ≤15th) was most accurately predicted by the AIMS at 4 months, whereas CP was most accurately predicted by the NSMDA at 12 months. In regards to serial assessments, the likelihood ratio for motor impairment increased with the number of delayed assessments. When combining both the NSMDA and AIMS the best accuracy was achieved at 4 months, although results were similar at 8 and 12 months. Interpretation Motor development during the first year of life in preterm infants assessed with the AIMS and NSMDA is predictive of later motor impairment at preschool age. However, false positives are common and therefore it is beneficial to follow-up children at high risk of motor impairment at more than one time point, or to use a

  17. Accuracy of Two Motor Assessments during the First Year of Life in Preterm Infants for Predicting Motor Outcome at Preschool Age.

    PubMed

    Spittle, Alicia J; Lee, Katherine J; Spencer-Smith, Megan; Lorefice, Lucy E; Anderson, Peter J; Doyle, Lex W

    2015-01-01

    The primary aim of this study was to investigate the accuracy of the Alberta Infant Motor Scale (AIMS) and Neuro-Sensory Motor Developmental Assessment (NSMDA) over the first year of life for predicting motor impairment at 4 years in preterm children. The secondary aims were to assess the predictive value of serial assessments over the first year and when using a combination of these two assessment tools in follow-up. Children born <30 weeks' gestation were prospectively recruited and assessed at 4, 8 and 12 months' corrected age using the AIMS and NSMDA. At 4 years' corrected age children were assessed for cerebral palsy (CP) and motor impairment using the Movement Assessment Battery for Children 2nd-edition (MABC-2). We calculated accuracy of the AIMS and NSMDA for predicting CP and MABC-2 scores ≤15th (at-risk of motor difficulty) and ≤5th centile (significant motor difficulty) for each test (AIMS and NSMDA) at 4, 8 and 12 months, for delay on one, two or all three of the time points over the first year, and finally for delay on both tests at each time point. Accuracy for predicting motor impairment was good for each test at each age, although false positives were common. Motor impairment on the MABC-2 (scores ≤5th and ≤15th) was most accurately predicted by the AIMS at 4 months, whereas CP was most accurately predicted by the NSMDA at 12 months. In regards to serial assessments, the likelihood ratio for motor impairment increased with the number of delayed assessments. When combining both the NSMDA and AIMS the best accuracy was achieved at 4 months, although results were similar at 8 and 12 months. Motor development during the first year of life in preterm infants assessed with the AIMS and NSMDA is predictive of later motor impairment at preschool age. However, false positives are common and therefore it is beneficial to follow-up children at high risk of motor impairment at more than one time point, or to use a combination of assessment tools. ACTR

  18. The accuracy of transvaginal sonography to detect endometriosis cyst

    NASA Astrophysics Data System (ADS)

    Diantika, M.; Gunardi, E. R.

    2017-08-01

    Endometriosis is common in women of reproductive age. Late diagnosis is still the main concern. Currently, noninvasive diagnostic testing, such as transvaginal sonography, is recommended. The aim of the current study was to evaluate the accuracy of transvaginal sonography in diagnosing endometrial cysts in patients in Cipto Mangunkusumo Hospital, Jakarta, Indonesia. This diagnostic study was carried out at Cipto Mangunkusumo Hospital between January 2014 and June 2015. Outpatients suspected have an endometrial cyst based on the patient history and a clinical examination was recruited. The patients were then evaluated using transvaginal sonography by an experienced sonologist, according to the research protocol. The gold standard test was a histological finding in the removed surgical mass. Ninety-eight patients were analyzed. An endometrial cyst was confirmed by histology in 85 patients (87%). The accuracy, sensitivity, specificity, positive predictive value and negative predictive value of transvaginal sonography was established to be 85% (a range of 71-99%), 93%, 77%, 96%, and 63%, respectively. A significantly higher area under the curve was identified using transvaginal sonogpraphy compared to that achieved with a clinical examination alone (85% versus 79%). Transvaginal sonography was useful in diagnosing endometrial cysts in outpatients and is recommended in daily clinical practice.

  19. Is a flat-line a good thing? On the privatization of Israel's healthcare system.

    PubMed

    Seidman, Guy I

    2010-01-01

    Israel presents an intriguing conundrum: on the one hand, it provides quality healthcare in a near-universal healthcare system; on the other, it has maintained healthcare costs level at approximately 7.7% of GDP. This comes at a time when all western nations struggle with one or both sides of the equation: how to offer affordable, good quality health care to the population while curbing the sharp rise in health related costs. This paper explains both how Israel has achieved this 'flat line" effect and the social and political costs of this achievement.

  20. Spacecraft attitude determination accuracy from mission experience

    NASA Technical Reports Server (NTRS)

    Brasoveanu, D.; Hashmall, J.; Baker, D.

    1994-01-01

    This document presents a compilation of the attitude accuracy attained by a number of satellites that have been supported by the Flight Dynamics Facility (FDF) at Goddard Space Flight Center (GSFC). It starts with a general description of the factors that influence spacecraft attitude accuracy. After brief descriptions of the missions supported, it presents the attitude accuracy results for currently active and older missions, including both three-axis stabilized and spin-stabilized spacecraft. The attitude accuracy results are grouped by the sensor pair used to determine the attitudes. A supplementary section is also included, containing the results of theoretical computations of the effects of variation of sensor accuracy on overall attitude accuracy.

  1. Accuracy Validation of Large-scale Block Adjustment without Control of ZY3 Images over China

    NASA Astrophysics Data System (ADS)

    Yang, Bo

    2016-06-01

    Mapping from optical satellite images without ground control is one of the goals of photogrammetry. Using 8802 three linear array stereo images (a total of 26406 images) of ZY3 over China, we propose a large-scale and non-control block adjustment method of optical satellite images based on the RPC model, in which a single image is regarded as an adjustment unit to be organized. To overcome the block distortion caused by unstable adjustment without ground control and the excessive accumulation of errors, we use virtual control points created by the initial RPC model of the images as the weighted observations and add them into the adjustment model to refine the adjustment. We use 8000 uniformly distributed high precision check points to evaluate the geometric accuracy of the DOM (Digital Ortho Model) and DSM (Digital Surface Model) production, for which the standard deviations of plane and elevation are 3.6 m and 4.2 m respectively. The geometric accuracy is consistent across the whole block and the mosaic accuracy of neighboring DOM is within a pixel, thus, the seamless mosaic could take place. This method achieves the goal of an accuracy of mapping without ground control better than 5 m for the whole China from ZY3 satellite images.

  2. Probe-level linear model fitting and mixture modeling results in high accuracy detection of differential gene expression.

    PubMed

    Lemieux, Sébastien

    2006-08-25

    The identification of differentially expressed genes (DEGs) from Affymetrix GeneChips arrays is currently done by first computing expression levels from the low-level probe intensities, then deriving significance by comparing these expression levels between conditions. The proposed PL-LM (Probe-Level Linear Model) method implements a linear model applied on the probe-level data to directly estimate the treatment effect. A finite mixture of Gaussian components is then used to identify DEGs using the coefficients estimated by the linear model. This approach can readily be applied to experimental design with or without replication. On a wholly defined dataset, the PL-LM method was able to identify 75% of the differentially expressed genes within 10% of false positives. This accuracy was achieved both using the three replicates per conditions available in the dataset and using only one replicate per condition. The method achieves, on this dataset, a higher accuracy than the best set of tools identified by the authors of the dataset, and does so using only one replicate per condition.

  3. Approximate Algorithms for Computing Spatial Distance Histograms with Accuracy Guarantees

    PubMed Central

    Grupcev, Vladimir; Yuan, Yongke; Tu, Yi-Cheng; Huang, Jin; Chen, Shaoping; Pandit, Sagar; Weng, Michael

    2014-01-01

    Particle simulation has become an important research tool in many scientific and engineering fields. Data generated by such simulations impose great challenges to database storage and query processing. One of the queries against particle simulation data, the spatial distance histogram (SDH) query, is the building block of many high-level analytics, and requires quadratic time to compute using a straightforward algorithm. Previous work has developed efficient algorithms that compute exact SDHs. While beating the naive solution, such algorithms are still not practical in processing SDH queries against large-scale simulation data. In this paper, we take a different path to tackle this problem by focusing on approximate algorithms with provable error bounds. We first present a solution derived from the aforementioned exact SDH algorithm, and this solution has running time that is unrelated to the system size N. We also develop a mathematical model to analyze the mechanism that leads to errors in the basic approximate algorithm. Our model provides insights on how the algorithm can be improved to achieve higher accuracy and efficiency. Such insights give rise to a new approximate algorithm with improved time/accuracy tradeoff. Experimental results confirm our analysis. PMID:24693210

  4. Accuracy of transthoracic lung ultrasound for diagnosing anesthesia-induced atelectasis in children.

    PubMed

    Acosta, Cecilia M; Maidana, Gustavo A; Jacovitti, Daniel; Belaunzarán, Agustín; Cereceda, Silvana; Rae, Elizabeth; Molina, Ananda; Gonorazky, Sergio; Bohm, Stephan H; Tusman, Gerardo

    2014-06-01

    The aim of this study was to test the accuracy of lung sonography (LUS) to diagnose anesthesia-induced atelectasis in children undergoing magnetic resonance imaging (MRI). Fifteen children with American Society of Anesthesiology's physical status classification I and aged 1 to 7 yr old were studied. Sevoflurane anesthesia was performed with the patients breathing spontaneously during the study period. After taking the reference lung MRI images, LUS was carried out using a linear probe of 6 to 12 MHz. Atelectasis was documented in MRI and LUS segmenting the chest into 12 similar anatomical regions. Images were analyzed by four blinded radiologists, two for LUS and two for MRI. The level of agreement for the diagnosis of atelectasis among observers was tested using the κ reliability index. Fourteen patients developed atelectasis mainly in the most dependent parts of the lungs. LUS showed 88% of sensitivity (95% CI, 74 to 96%), 89% of specificity (95% CI, 83 to 94%), and 88% of accuracy (95% CI, 83 to 92%) for the diagnosis of atelectasis taking MRI as reference. The agreement between the two radiologists for diagnosing atelectasis by MRI was very good (κ, 0.87; 95% CI, 0.72 to 1; P < 0.0001) as was the agreement between the two radiologists for detecting atelectasis by LUS (κ, 0.90; 95% CI, 0.75 to 1; P < 0.0001). MRI and LUS also showed good agreement when data from the four radiologists were pooled and examined together (κ, 0.75; 95% CI, 0.69 to 0.81; P < 0.0001). LUS is an accurate, safe, and simple bedside method for diagnosing anesthesia-induced atelectasis in children.

  5. Geoid undulation accuracy

    NASA Technical Reports Server (NTRS)

    Rapp, Richard H.

    1993-01-01

    The determination of the geoid and equipotential surface of the Earth's gravity field, has long been of interest to geodesists and oceanographers. The geoid provides a surface to which the actual ocean surface can be compared with the differences implying information on the circulation patterns of the oceans. For use in oceanographic applications the geoid is ideally needed to a high accuracy and to a high resolution. There are applications that require geoid undulation information to an accuracy of +/- 10 cm with a resolution of 50 km. We are far from this goal today but substantial improvement in geoid determination has been made. In 1979 the cumulative geoid undulation error to spherical harmonic degree 20 was +/- 1.4 m for the GEM10 potential coefficient model. Today the corresponding value has been reduced to +/- 25 cm for GEM-T3 or +/- 11 cm for the OSU91A model. Similar improvements are noted by harmonic degree (wave-length) and in resolution. Potential coefficient models now exist to degree 360 based on a combination of data types. This paper discusses the accuracy changes that have taken place in the past 12 years in the determination of geoid undulations.

  6. The Accuracy and Reliability of Crowdsource Annotations of Digital Retinal Images

    PubMed Central

    Mitry, Danny; Zutis, Kris; Dhillon, Baljean; Peto, Tunde; Hayat, Shabina; Khaw, Kay-Tee; Morgan, James E.; Moncur, Wendy; Trucco, Emanuele; Foster, Paul J.

    2016-01-01

    Purpose Crowdsourcing is based on outsourcing computationally intensive tasks to numerous individuals in the online community who have no formal training. Our aim was to develop a novel online tool designed to facilitate large-scale annotation of digital retinal images, and to assess the accuracy of crowdsource grading using this tool, comparing it to expert classification. Methods We used 100 retinal fundus photograph images with predetermined disease criteria selected by two experts from a large cohort study. The Amazon Mechanical Turk Web platform was used to drive traffic to our site so anonymous workers could perform a classification and annotation task of the fundus photographs in our dataset after a short training exercise. Three groups were assessed: masters only, nonmasters only and nonmasters with compulsory training. We calculated the sensitivity, specificity, and area under the curve (AUC) of receiver operating characteristic (ROC) plots for all classifications compared to expert grading, and used the Dice coefficient and consensus threshold to assess annotation accuracy. Results In total, we received 5389 annotations for 84 images (excluding 16 training images) in 2 weeks. A specificity and sensitivity of 71% (95% confidence interval [CI], 69%–74%) and 87% (95% CI, 86%–88%) was achieved for all classifications. The AUC in this study for all classifications combined was 0.93 (95% CI, 0.91–0.96). For image annotation, a maximal Dice coefficient (∼0.6) was achieved with a consensus threshold of 0.25. Conclusions This study supports the hypothesis that annotation of abnormalities in retinal images by ophthalmologically naive individuals is comparable to expert annotation. The highest AUC and agreement with expert annotation was achieved in the nonmasters with compulsory training group. Translational Relevance The use of crowdsourcing as a technique for retinal image analysis may be comparable to expert graders and has the potential to deliver

  7. Technical Note: Quantitative accuracy evaluation for spectral images from a detector-based spectral CT scanner using an iodine phantom.

    PubMed

    Duan, Xinhui; Arbique, Gary; Guild, Jeffrey; Xi, Yin; Anderson, Jon

    2018-05-01

    The purpose of this study was to evaluate the quantitative accuracy of spectral images from a detector-based spectral CT scanner using a phantom with iodine-loaded inserts. A 40-cm long-body phantom with seven iodine inserts (2-20 mg/ml of iodine) was used in the study. The inserts could be placed at 5.5 or 10.5 cm from the phantom axis. The phantom was scanned five times for each insert configuration using 120 kVp tube voltage. A set of iodine, virtual noncontrast, effective atomic number, and virtual monoenergetic spectral CT images were generated and measurements were made for all the iodine rods. Measured values were compared with reference values calculated from the chemical composition information provided by the phantom manufacturer. Radiation dose from the spectral CT was compared to a conventional CT using a CTDI (32 cm) phantom. Good agreement between measurements and reference values was achieved for all types of spectral images. The differences ranged from -0.46 to 0.1 mg/ml for iodine concentration, -9.95 to 6.41 HU for virtual noncontrast images, 0.12 to 0.35 for effective Z images, and -17.7 to 55.7 HU for virtual monoenergetic images. For a similar CTDIvol, image noise from the conventional CT was 10% lower than the spectral CT. The detector-based spectral CT can achieve accurate spectral measurements on iodine concentration, virtual non-contrast images, effective atomic numbers, and virtual monoenergetic images. © 2018 American Association of Physicists in Medicine.

  8. Matters of accuracy and conventionality: prior accuracy guides children's evaluations of others' actions.

    PubMed

    Scofield, Jason; Gilpin, Ansley Tullos; Pierucci, Jillian; Morgan, Reed

    2013-03-01

    Studies show that children trust previously reliable sources over previously unreliable ones (e.g., Koenig, Clément, & Harris, 2004). However, it is unclear from these studies whether children rely on accuracy or conventionality to determine the reliability and, ultimately, the trustworthiness of a particular source. In the current study, 3- and 4-year-olds were asked to endorse and imitate one of two actors performing an unfamiliar action, one actor who was unconventional but successful and one who was conventional but unsuccessful. These data demonstrated that children preferred endorsing and imitating the unconventional but successful actor. Results suggest that when the accuracy and conventionality of a source are put into conflict, children may give priority to accuracy over conventionality when estimating the source's reliability and, ultimately, when deciding who to trust.

  9. The methodological quality of diagnostic test accuracy studies for musculoskeletal conditions can be improved.

    PubMed

    Henschke, Nicholas; Keuerleber, Julia; Ferreira, Manuela; Maher, Christopher G; Verhagen, Arianne P

    2014-04-01

    To provide an overview of reporting and methodological quality in diagnostic test accuracy (DTA) studies in the musculoskeletal field and evaluate the use of the QUality Assessment of Diagnostic Accuracy Studies (QUADAS) checklist. A literature review identified all systematic reviews that evaluated the accuracy of clinical tests to diagnose musculoskeletal conditions and used the QUADAS checklist. Two authors screened all identified reviews and extracted data on the target condition, index tests, reference standard, included studies, and QUADAS items. A descriptive analysis of the QUADAS checklist was performed, along with Rasch analysis to examine the construct validity and internal reliability. A total of 19 systematic reviews were included, which provided data on individual items of the QUADAS checklist for 392 DTA studies. In the musculoskeletal field, uninterpretable or intermediate test results are commonly not reported, with 175 (45%) studies scoring "no" to this item. The proportion of studies fulfilling certain items varied from 22% (item 11) to 91% (item 3). The interrater reliability of the QUADAS checklist was good and Rasch analysis showed excellent construct validity and internal consistency. This overview identified areas where the reporting and performance of diagnostic studies within the musculoskeletal field can be improved. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Motor Inhibition Affects the Speed But Not Accuracy of Aimed Limb Movements in an Insect

    PubMed Central

    Calas-List, Delphine; Clare, Anthony J.; Komissarova, Alexandra; Nielsen, Thomas A.

    2014-01-01

    When reaching toward a target, human subjects use slower movements to achieve higher accuracy, and this can be accompanied by increased limb impedance (stiffness, viscosity) that stabilizes movements against motor noise and external perturbation. In arthropods, the activity of common inhibitory motor neurons influences limb impedance, so we hypothesized that this might provide a mechanism for speed and accuracy control of aimed movements in insects. We recorded simultaneously from excitatory leg motor neurons and from an identified common inhibitory motor neuron (CI1) in locusts that performed natural aimed scratching movements. We related limb movement kinematics to recorded motor activity and demonstrate that imposed alterations in the activity of CI1 influenced these kinematics. We manipulated the activity of CI1 by injecting depolarizing or hyperpolarizing current or killing the cell using laser photoablation. Naturally higher levels of inhibitory activity accompanied faster movements. Experimentally biasing the firing rate downward, or stopping firing completely, led to slower movements mediated by changes at several joints of the limb. Despite this, we found no effect on overall movement accuracy. We conclude that inhibitory modulation of joint stiffness has effects across most of the working range of the insect limb, with a pronounced effect on the overall velocity of natural movements independent of their accuracy. Passive joint forces that are greatest at extreme joint angles may enhance accuracy and are not affected by motor inhibition. PMID:24872556

  11. Anatomy-aware measurement of segmentation accuracy

    NASA Astrophysics Data System (ADS)

    Tizhoosh, H. R.; Othman, A. A.

    2016-03-01

    Quantifying the accuracy of segmentation and manual delineation of organs, tissue types and tumors in medical images is a necessary measurement that suffers from multiple problems. One major shortcoming of all accuracy measures is that they neglect the anatomical significance or relevance of different zones within a given segment. Hence, existing accuracy metrics measure the overlap of a given segment with a ground-truth without any anatomical discrimination inside the segment. For instance, if we understand the rectal wall or urethral sphincter as anatomical zones, then current accuracy measures ignore their significance when they are applied to assess the quality of the prostate gland segments. In this paper, we propose an anatomy-aware measurement scheme for segmentation accuracy of medical images. The idea is to create a "master gold" based on a consensus shape containing not just the outline of the segment but also the outlines of the internal zones if existent or relevant. To apply this new approach to accuracy measurement, we introduce the anatomy-aware extensions of both Dice coefficient and Jaccard index and investigate their effect using 500 synthetic prostate ultrasound images with 20 different segments for each image. We show that through anatomy-sensitive calculation of segmentation accuracy, namely by considering relevant anatomical zones, not only the measurement of individual users can change but also the ranking of users' segmentation skills may require reordering.

  12. Three-dimensional single-molecule localization with nanometer accuracy using Metal-Induced Energy Transfer (MIET) imaging

    NASA Astrophysics Data System (ADS)

    Karedla, Narain; Chizhik, Anna M.; Stein, Simon C.; Ruhlandt, Daja; Gregor, Ingo; Chizhik, Alexey I.; Enderlein, Jörg

    2018-05-01

    Our paper presents the first theoretical and experimental study using single-molecule Metal-Induced Energy Transfer (smMIET) for localizing single fluorescent molecules in three dimensions. Metal-Induced Energy Transfer describes the resonant energy transfer from the excited state of a fluorescent emitter to surface plasmons in a metal nanostructure. This energy transfer is strongly distance-dependent and can be used to localize an emitter along one dimension. We have used Metal-Induced Energy Transfer in the past for localizing fluorescent emitters with nanometer accuracy along the optical axis of a microscope. The combination of smMIET with single-molecule localization based super-resolution microscopy that provides nanometer lateral localization accuracy offers the prospect of achieving isotropic nanometer localization accuracy in all three spatial dimensions. We give a thorough theoretical explanation and analysis of smMIET, describe its experimental requirements, also in its combination with lateral single-molecule localization techniques, and present first proof-of-principle experiments using dye molecules immobilized on top of a silica spacer, and of dye molecules embedded in thin polymer films.

  13. Three-dimensional accuracy of different impression techniques for dental implants

    PubMed Central

    Nakhaei, Mohammadreza; Madani, Azam S; Moraditalab, Azizollah; Haghi, Hamidreza Rajati

    2015-01-01

    Background: Accurate impression making is an essential prerequisite for achieving a passive fit between the implant and the superstructure. The aim of this in vitro study was to compare the three-dimensional accuracy of open-tray and three closed-tray impression techniques. Materials and Methods: Three acrylic resin mandibular master models with four parallel implants were used: Biohorizons (BIO), Straumann tissue-level (STL), and Straumann bone-level (SBL). Forty-two putty/wash polyvinyl siloxane impressions of the models were made using open-tray and closed-tray techniques. Closed-tray impressions were made using snap-on (STL model), transfer coping (TC) (BIO model) and TC plus plastic cap (TC-Cap) (SBL model). The impressions were poured with type IV stone, and the positional accuracy of the implant analog heads in each dimension (x, y and z axes), and the linear displacement (ΔR) were evaluated using a coordinate measuring machine. Data were analyzed using ANOVA and post-hoc Tukey tests (α = 0.05). Results: The ΔR values of the snap-on technique were significantly lower than those of TC and TC-Cap techniques (P < 0.001). No significant differences were found between closed and open impression techniques for STL in Δx, Δy, Δz and ΔR values (P = 0.444, P = 0.181, P = 0.835 and P = 0.911, respectively). Conclusion: Considering the limitations of this study, the snap-on implant-level impression technique resulted in more three-dimensional accuracy than TC and TC-Cap, but it was similar to the open-tray technique. PMID:26604956

  14. Validating continuous digital light processing (cDLP) additive manufacturing accuracy and tissue engineering utility of a dye-initiator package.

    PubMed

    Wallace, Jonathan; Wang, Martha O; Thompson, Paul; Busso, Mallory; Belle, Vaijayantee; Mammoser, Nicole; Kim, Kyobum; Fisher, John P; Siblani, Ali; Xu, Yueshuo; Welter, Jean F; Lennon, Donald P; Sun, Jiayang; Caplan, Arnold I; Dean, David

    2014-03-01

    This study tested the accuracy of tissue engineering scaffold rendering via the continuous digital light processing (cDLP) light-based additive manufacturing technology. High accuracy (i.e., <50 µm) allows the designed performance of features relevant to three scale spaces: cell-scaffold, scaffold-tissue, and tissue-organ interactions. The biodegradable polymer poly (propylene fumarate) was used to render highly accurate scaffolds through the use of a dye-initiator package, TiO2 and bis (2,4,6-trimethylbenzoyl)phenylphosphine oxide. This dye-initiator package facilitates high accuracy in the Z dimension. Linear, round, and right-angle features were measured to gauge accuracy. Most features showed accuracies between 5.4-15% of the design. However, one feature, an 800 µm diameter circular pore, exhibited a 35.7% average reduction of patency. Light scattered in the x, y directions by the dye may have reduced this feature's accuracy. Our new fine-grained understanding of accuracy could be used to make further improvements by including corrections in the scaffold design software. Successful cell attachment occurred with both canine and human mesenchymal stem cells (MSCs). Highly accurate cDLP scaffold rendering is critical to the design of scaffolds that both guide bone regeneration and that fully resorb. Scaffold resorption must occur for regenerated bone to be remodeled and, thereby, achieve optimal strength.

  15. Return on research investments: personal good versus public good

    NASA Astrophysics Data System (ADS)

    Fox, P. A.

    2017-12-01

    For some time the outputs, i.e. what's produced, of publicly and privately funded research while necessary, are far from sufficient, when considering an overall return on (research) investment. At the present time products such as peer-reviewed papers, websites, data, and software are recognized by funders on timescales related to research awards and reporting. However, from a consumer perspective impact and value are determined at the time a product is discovered, accessed, assessed and used. As is often the case, the perspectives of producer and consumer communities can be distinct and not intersect at all. We contrast personal good, i.e. credit, reputation, with that of public good, e.g. interest, leverage, exploitation, and more. This presentation will elaborate on both the metaphorical and idealogical aspects of applying a "return on investment" frame for the topic of assessing "good".

  16. Learning-related skills and academic achievement in academically at-risk first graders

    PubMed Central

    Cerda, Carissa A.; Im, Myung Hee; Hughes, Jan N.

    2015-01-01

    Using an academically at-risk, ethnically diverse sample of 744 first-grade children, this study tested a multi-method (i.e., child performance measures, teacher ratings, and peer ratings) measurement model of learning-related skills (i.e., effortful control [EC], behavioral self-regulation [BSR], and social competence [SC]), and their shared and unique contributions to children's reading and math achievement, above the effect of demographic variables. The hypothesized correlated factor measurement model demonstrated relatively good fit, with BSR and SC correlated highly with one another and moderately with EC. When entered in separate regression equations, EC and BSR each predicted children's reading and math achievement; SC only predicted reading achievement. When considered simultaneously, neither EC, BSR, nor SC contributed independently to reading achievement; however, EC had a direct effect on math achievement and an indirect effect on reading achievement via both BSR and SC. Implications for research and early intervention efforts are discussed. PMID:25908886

  17. Spectral Accuracy and Sulfur Counting Capabilities of the LTQ-FT-ICR and the LTQ-Orbitrap XL for Small Molecule Analysis

    NASA Astrophysics Data System (ADS)

    Blake, Samantha L.; Walker, S. Hunter; Muddiman, David C.; Hinks, David; Beck, Keith R.

    2011-12-01

    Color Index Disperse Yellow 42 (DY42), a high-volume disperse dye for polyester, was used to compare the capabilities of the LTQ-Orbitrap XL and the LTQ-FT-ICR with respect to mass measurement accuracy (MMA), spectral accuracy, and sulfur counting. The results of this research will be used in the construction of a dye database for forensic purposes; the additional spectral information will increase the confidence in the identification of unknown dyes found in fibers at crime scenes. Initial LTQ-Orbitrap XL data showed MMAs greater than 3 ppm and poor spectral accuracy. Modification of several Orbitrap installation parameters (e.g., deflector voltage) resulted in a significant improvement of the data. The LTQ-FT-ICR and LTQ-Orbitrap XL (after installation parameters were modified) exhibited MMA ≤ 3 ppm, good spectral accuracy (χ2 values for the isotopic distribution ≤ 2), and were correctly able to ascertain the number of sulfur atoms in the compound at all resolving powers investigated for AGC targets of 5.00 × 105 and 1.00 × 106.

  18. Smart Device-Supported BDS/GNSS Real-Time Kinematic Positioning for Sub-Meter-Level Accuracy in Urban Location-Based Services

    PubMed Central

    Wang, Liang; Li, Zishen; Zhao, Jiaojiao; Zhou, Kai; Wang, Zhiyu; Yuan, Hong

    2016-01-01

    Using mobile smart devices to provide urban location-based services (LBS) with sub-meter-level accuracy (around 0.5 m) is a major application field for future global navigation satellite system (GNSS) development. Real-time kinematic (RTK) positioning, which is a widely used GNSS-based positioning approach, can improve the accuracy from about 10–20 m (achieved by the standard positioning services) to about 3–5 cm based on the geodetic receivers. In using the smart devices to achieve positioning with sub-meter-level accuracy, a feasible solution of combining the low-cost GNSS module and the smart device is proposed in this work and a user-side GNSS RTK positioning software was developed from scratch based on the Android platform. Its real-time positioning performance was validated by BeiDou Navigation Satellite System/Global Positioning System (BDS/GPS) combined RTK positioning under the conditions of a static and kinematic (the velocity of the rover was 50–80 km/h) mode in a real urban environment with a SAMSUNG Galaxy A7 smartphone. The results show that the fixed-rates of ambiguity resolution (the proportion of epochs of ambiguities fixed) for BDS/GPS combined RTK in the static and kinematic tests were about 97% and 90%, respectively, and the average positioning accuracies (RMS) were better than 0.15 m (horizontal) and 0.25 m (vertical) for the static test, and 0.30 m (horizontal) and 0.45 m (vertical) for the kinematic test. PMID:28009835

  19. Predictors for good functional outcome after neurocritical care.

    PubMed

    Kiphuth, Ines C; Schellinger, Peter D; Köhrmann, Martin; Bardutzky, Jürgen; Lücking, Hannes; Kloska, Stephan; Schwab, Stefan; Huttner, Hagen B

    2010-01-01

    There are only limited data on the long-term outcome of patients receiving specialized neurocritical care. In this study we analyzed survival, long-term mortality and functional outcome after neurocritical care and determined predictors for good functional outcome. We retrospectively investigated 796 consecutive patients admitted to a non-surgical neurologic intensive care unit over a period of two years (2006 and 2007). Demographic and clinical parameters were analyzed. Depending on the diagnosis, we grouped patients according to their diseases (cerebral ischemia, intracranial hemorrhage (ICH), subarachnoid hemorrhage (SAH), meningitis/encephalitis, epilepsy, Guillain-Barré syndrome (GBS) and myasthenia gravis (MG), neurodegenerative diseases and encephalopathy, cerebral neoplasm and intoxication). Clinical parameters, mortality and functional outcome of all treated patients were analyzed. Functional outcome (using the modified Rankin Scale, mRS) one year after discharge was assessed by a mailed questionnaire or telephone interview. Outcome was dichotomized into good (mRS ≤ 2) and poor (mRS ≥ 3). Logistic regression analyses were calculated to determine independent predictors for good functional outcome. Overall in-hospital mortality amounted to 22.5% of all patients, and a good long-term functional outcome was achieved in 28.4%. The parameters age, length of ventilation (LOV), admission diagnosis of ICH, GBS/MG, and inoperable cerebral neoplasm as well as Therapeutic Intervention Scoring System (TISS)-28 on Day 1 were independently associated with functional outcome after one year. This investigation revealed that age, LOV and TISS-28 on Day 1 were strongly predictive for the outcome. The diagnoses of hemorrhagic stroke and cerebral neoplasm leading to neurocritical care predispose for functional dependence or death, whereas patients with GBS and MG are more likely to recover after neurocritical care.

  20. Predictors for good functional outcome after neurocritical care

    PubMed Central

    2010-01-01

    Introduction There are only limited data on the long-term outcome of patients receiving specialized neurocritical care. In this study we analyzed survival, long-term mortality and functional outcome after neurocritical care and determined predictors for good functional outcome. Methods We retrospectively investigated 796 consecutive patients admitted to a non-surgical neurologic intensive care unit over a period of two years (2006 and 2007). Demographic and clinical parameters were analyzed. Depending on the diagnosis, we grouped patients according to their diseases (cerebral ischemia, intracranial hemorrhage (ICH), subarachnoid hemorrhage (SAH), meningitis/encephalitis, epilepsy, Guillain-Barré syndrome (GBS) and myasthenia gravis (MG), neurodegenerative diseases and encephalopathy, cerebral neoplasm and intoxication). Clinical parameters, mortality and functional outcome of all treated patients were analyzed. Functional outcome (using the modified Rankin Scale, mRS) one year after discharge was assessed by a mailed questionnaire or telephone interview. Outcome was dichotomized into good (mRS ≤ 2) and poor (mRS ≥ 3). Logistic regression analyses were calculated to determine independent predictors for good functional outcome. Results Overall in-hospital mortality amounted to 22.5% of all patients, and a good long-term functional outcome was achieved in 28.4%. The parameters age, length of ventilation (LOV), admission diagnosis of ICH, GBS/MG, and inoperable cerebral neoplasm as well as Therapeutic Intervention Scoring System (TISS)-28 on Day 1 were independently associated with functional outcome after one year. Conclusions This investigation revealed that age, LOV and TISS-28 on Day 1 were strongly predictive for the outcome. The diagnoses of hemorrhagic stroke and cerebral neoplasm leading to neurocritical care predispose for functional dependence or death, whereas patients with GBS and MG are more likely to recover after neurocritical care. PMID:20646313

  1. Ground Truth Sampling and LANDSAT Accuracy Assessment

    NASA Technical Reports Server (NTRS)

    Robinson, J. W.; Gunther, F. J.; Campbell, W. J.

    1982-01-01

    It is noted that the key factor in any accuracy assessment of remote sensing data is the method used for determining the ground truth, independent of the remote sensing data itself. The sampling and accuracy procedures developed for nuclear power plant siting study are described. The purpose of the sampling procedure was to provide data for developing supervised classifications for two study sites and for assessing the accuracy of that and the other procedures used. The purpose of the accuracy assessment was to allow the comparison of the cost and accuracy of various classification procedures as applied to various data types.

  2. Test expectancy affects metacomprehension accuracy.

    PubMed

    Thiede, Keith W; Wiley, Jennifer; Griffin, Thomas D

    2011-06-01

    Theory suggests that the accuracy of metacognitive monitoring is affected by the cues used to judge learning. Researchers have improved monitoring accuracy by directing attention to more appropriate cues; however, this is the first study to more directly point students to more appropriate cues using instructions regarding tests and practice tests. The purpose of the present study was to examine whether the accuracy metacognitive monitoring was affected by the nature of the test expected. Students (N= 59) were randomly assigned to one of two test expectancy groups (memory vs. inference). Then after reading texts, judging learning, completed both memory and inference tests. Test performance and monitoring accuracy were superior when students received the kind of test they had been led to expect rather than the unexpected test. Tests influence students' perceptions of what constitutes learning. Our findings suggest that this could affect how students prepare for tests and how they monitoring their own learning. ©2010 The British Psychological Society.

  3. Robust sub-millihertz-level offset locking for transferring optical frequency accuracy and for atomic two-photon spectroscopy.

    PubMed

    Cheng, Wang-Yau; Chen, Ting-Ju; Lin, Chia-Wei; Chen, Bo-Wei; Yang, Ya-Po; Hsu, Hung Yi

    2017-02-06

    Robust sub-millihertz-level offset locking was achieved with a simple scheme, by which we were able to transfer the laser frequency stability and accuracy from either cesium-stabilized diode laser or comb laser to the other diode lasers who had serious frequency jitter previously. The offset lock developed in this paper played an important role in atomic two-photon spectroscopy with which record resolution and new determination on the hyperfine constants of cesium atom were achieved. A quantum-interference experiment was performed to show the improvement of light coherence as an extended design was implemented.

  4. Real longitudinal data analysis for real people: building a good enough mixed model.

    PubMed

    Cheng, Jing; Edwards, Lloyd J; Maldonado-Molina, Mildred M; Komro, Kelli A; Muller, Keith E

    2010-02-20

    Mixed effects models have become very popular, especially for the analysis of longitudinal data. One challenge is how to build a good enough mixed effects model. In this paper, we suggest a systematic strategy for addressing this challenge and introduce easily implemented practical advice to build mixed effects models. A general discussion of the scientific strategies motivates the recommended five-step procedure for model fitting. The need to model both the mean structure (the fixed effects) and the covariance structure (the random effects and residual error) creates the fundamental flexibility and complexity. Some very practical recommendations help to conquer the complexity. Centering, scaling, and full-rank coding of all the predictor variables radically improve the chances of convergence, computing speed, and numerical accuracy. Applying computational and assumption diagnostics from univariate linear models to mixed model data greatly helps to detect and solve the related computational problems. Applying computational and assumption diagnostics from the univariate linear models to the mixed model data can radically improve the chances of convergence, computing speed, and numerical accuracy. The approach helps to fit more general covariance models, a crucial step in selecting a credible covariance model needed for defensible inference. A detailed demonstration of the recommended strategy is based on data from a published study of a randomized trial of a multicomponent intervention to prevent young adolescents' alcohol use. The discussion highlights a need for additional covariance and inference tools for mixed models. The discussion also highlights the need for improving how scientists and statisticians teach and review the process of finding a good enough mixed model. (c) 2009 John Wiley & Sons, Ltd.

  5. An assessment of the accuracy of orthotropic photoelasticity

    NASA Technical Reports Server (NTRS)

    Hyer, M. W.; Liu, D. H.

    1984-01-01

    The accuracy of orthotropic photoelasticity was studied. The study consisted of both theoretical and experimental phases. In the theoretical phase a stress-optic law was developed. The stress-optic law included the effects of residual birefringence in the relation between applied stress and the material's optical response. The experimental phase had several portions. First, it was shown that four-point bending tests and the concept of an optical neutral axis could be conveniently used to calibrate the stress-optic behavior of the material. Second, the actual optical response of an orthotropic disk in diametral compression was compared with theoretical predictions. Third, the stresses in the disk were determined from the observed optical response, the stress-optic law, and a finite-difference form of the plane stress equilibrium equations. It was concluded that orthotropic photoelasticity is not as accurate as isotropic photoelasticity. This is believed to be due to the lack of good fringe resolution and the low sensitivity of most orthotropic photoelastic materials.

  6. Modeling additive and non-additive effects in a hybrid population using genome-wide genotyping: prediction accuracy implications

    PubMed Central

    Bouvet, J-M; Makouanzi, G; Cros, D; Vigneron, Ph

    2016-01-01

    Hybrids are broadly used in plant breeding and accurate estimation of variance components is crucial for optimizing genetic gain. Genome-wide information may be used to explore models designed to assess the extent of additive and non-additive variance and test their prediction accuracy for the genomic selection. Ten linear mixed models, involving pedigree- and marker-based relationship matrices among parents, were developed to estimate additive (A), dominance (D) and epistatic (AA, AD and DD) effects. Five complementary models, involving the gametic phase to estimate marker-based relationships among hybrid progenies, were developed to assess the same effects. The models were compared using tree height and 3303 single-nucleotide polymorphism markers from 1130 cloned individuals obtained via controlled crosses of 13 Eucalyptus urophylla females with 9 Eucalyptus grandis males. Akaike information criterion (AIC), variance ratios, asymptotic correlation matrices of estimates, goodness-of-fit, prediction accuracy and mean square error (MSE) were used for the comparisons. The variance components and variance ratios differed according to the model. Models with a parent marker-based relationship matrix performed better than those that were pedigree-based, that is, an absence of singularities, lower AIC, higher goodness-of-fit and accuracy and smaller MSE. However, AD and DD variances were estimated with high s.es. Using the same criteria, progeny gametic phase-based models performed better in fitting the observations and predicting genetic values. However, DD variance could not be separated from the dominance variance and null estimates were obtained for AA and AD effects. This study highlighted the advantages of progeny models using genome-wide information. PMID:26328760

  7. Predictive accuracy of the Historical-Clinical-Risk Management-20 for violence in forensic psychiatric wards in Japan.

    PubMed

    Arai, Kaoru; Takano, Ayumi; Nagata, Takako; Hirabayashi, Naotsugu

    2017-12-01

    Most structured assessment tools for assessing risk of violence were developed in Western countries, and evidence for their effectiveness is not well established in Asian countries. Our aim was to examine the predictive accuracy of the Historical-Clinical-Risk Management-20 (HCR-20) for violence in forensic mental health inpatient units in Japan. A retrospective record study was conducted with a complete 2008-2013 cohort of forensic psychiatric inpatients at the National Center Hospital of Neurology and Psychiatry, Tokyo. Forensic psychiatrists were trained in use of the HCR-20 and asked to complete it as part of their admission assessment. The completed forms were then retained by the researchers and not used in clinical practice; for this, clinicians relied solely on national legally required guidelines. Violent outcomes were determined at 3 and 6 months after the assessment. Receiver operating characteristic analysis was used to calculate the predictive accuracy of the HCR-20 for violence. Area under the curve analyses suggested that the HCR-20 total score is a good predictor of violence in this cohort, with the clinical and risk sub-scales showing good predictive accuracy, but the historical sub-scale not doing so. Area under the curve figures were similar at 3 months and at 6 months. Our results are consistent with studies previously conducted in Western countries. This suggests that the HCR-20 is an effective tool for supporting risk of violence assessment in Japanese forensic psychiatric wards. Its widespread use in clinical practice could enhance safety and would certainly promote transparency in risk-related decision-making. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  8. High accuracy GNSS based navigation in GEO

    NASA Astrophysics Data System (ADS)

    Capuano, Vincenzo; Shehaj, Endrit; Blunt, Paul; Botteron, Cyril; Farine, Pierre-André

    2017-07-01

    Although significant improvements in efficiency and performance of communication satellites have been achieved in the past decades, it is expected that the demand for new platforms in Geostationary Orbit (GEO) and for the On-Orbit Servicing (OOS) on the existing ones will continue to rise. Indeed, the GEO orbit is used for many applications including direct broadcast as well as communications. At the same time, Global Navigation Satellites System (GNSS), originally designed for land, maritime and air applications, has been successfully used as navigation system in Low Earth Orbit (LEO) and its further utilization for navigation of geosynchronous satellites becomes a viable alternative offering many advantages over present ground based methods. Following our previous studies of GNSS signal characteristics in Medium Earth Orbit (MEO), GEO and beyond, in this research we specifically investigate the processing of different GNSS signals, with the goal to determine the best navigation performance they can provide in a GEO mission. Firstly, a detailed selection among different GNSS signals and different combinations of them is discussed, taking into consideration the L1 and L5 frequency bands, and the GPS and Galileo constellations. Then, the implementation of an Orbital Filter is summarized, which adaptively fuses the GN1SS observations with an accurate orbital forces model. Finally, simulation tests of the navigation performance achievable by processing the selected combination of GNSS signals are carried out. The results obtained show an achievable positioning accuracy of less than one meter. In addition, hardware-in-the-loop tests are presented using a COTS receiver connected to our GNSS Spirent simulator, in order to collect real-time hardware-in-the-loop observations and process them by the proposed navigation module.

  9. Does a Sensory Processing Deficit Explain Counting Accuracy on Rapid Visual Sequencing Tasks in Adults with and without Dyslexia?

    ERIC Educational Resources Information Center

    Conlon, Elizabeth G.; Wright, Craig M.; Norris, Karla; Chekaluk, Eugene

    2011-01-01

    The experiments conducted aimed to investigate whether reduced accuracy when counting stimuli presented in rapid temporal sequence in adults with dyslexia could be explained by a sensory processing deficit, a general slowing in processing speed or difficulties shifting attention between stimuli. To achieve these aims, the influence of the…

  10. Accuracy improvement of quantitative analysis by spatial confinement in laser-induced breakdown spectroscopy.

    PubMed

    Guo, L B; Hao, Z Q; Shen, M; Xiong, W; He, X N; Xie, Z Q; Gao, M; Li, X Y; Zeng, X Y; Lu, Y F

    2013-07-29

    To improve the accuracy of quantitative analysis in laser-induced breakdown spectroscopy, the plasma produced by a Nd:YAG laser from steel targets was confined by a cavity. A number of elements with low concentrations, such as vanadium (V), chromium (Cr), and manganese (Mn), in the steel samples were investigated. After the optimization of the cavity dimension and laser fluence, significant enhancement factors of 4.2, 3.1, and 2.87 in the emission intensity of V, Cr, and Mn lines, respectively, were achieved at a laser fluence of 42.9 J/cm(2) using a hemispherical cavity (diameter: 5 mm). More importantly, the correlation coefficient of the V I 440.85/Fe I 438.35 nm was increased from 0.946 (without the cavity) to 0.981 (with the cavity); and similar results for Cr I 425.43/Fe I 425.08 nm and Mn I 476.64/Fe I 492.05 nm were also obtained. Therefore, it was demonstrated that the accuracy of quantitative analysis with low concentration elements in steel samples was improved, because the plasma became uniform with spatial confinement. The results of this study provide a new pathway for improving the accuracy of quantitative analysis of LIBS.

  11. Feature instructions improve face-matching accuracy

    PubMed Central

    Bindemann, Markus

    2018-01-01

    Identity comparisons of photographs of unfamiliar faces are prone to error but important for applied settings, such as person identification at passport control. Finding techniques to improve face-matching accuracy is therefore an important contemporary research topic. This study investigated whether matching accuracy can be improved by instruction to attend to specific facial features. Experiment 1 showed that instruction to attend to the eyebrows enhanced matching accuracy for optimized same-day same-race face pairs but not for other-race faces. By contrast, accuracy was unaffected by instruction to attend to the eyes, and declined with instruction to attend to ears. Experiment 2 replicated the eyebrow-instruction improvement with a different set of same-race faces, comprising both optimized same-day and more challenging different-day face pairs. These findings suggest that instruction to attend to specific features can enhance face-matching accuracy, but feature selection is crucial and generalization across face sets may be limited. PMID:29543822

  12. Relationship between resolution and accuracy of four intraoral scanners in complete-arch impressions

    PubMed Central

    Pascual-Moscardó, Agustín; Camps, Isabel

    2018-01-01

    Background The scanner does not measure the dental surface continually. Instead, it generates a point cloud, and these points are then joined to form the scanned object. This approximation will depend on the number of points generated (resolution), which can lead to low accuracy (trueness and precision) when fewer points are obtained. The purpose of this study is to determine the resolution of four intraoral digital imaging systems and to demonstrate the relationship between accuracy and resolution of the intraoral scanner in impressions of a complete dental arch. Material and Methods A master cast of the complete maxillary arch was prepared with different dental preparations. Using four digital impression systems, the cast was scanned inside of a black methacrylate box, obtaining a total of 40 digital impressions from each scanner. The resolution was obtained by dividing the number of points of each digital impression by the total surface area of the cast. Accuracy was evaluated using a three-dimensional measurement software, using the “best alignment” method of the casts with a highly faithful reference model obtained from an industrial scanner. Pearson correlation was used for statistical analysis of the data. Results Of the intraoral scanners, Omnicam is the system with the best resolution, with 79.82 points per mm2, followed by True Definition with 54.68 points per mm2, Trios with 41.21 points per mm2, and iTero with 34.20 points per mm2. However, the study found no relationship between resolution and accuracy of the study digital impression systems (P >0.05), except for Omnicam and its precision. Conclusions The resolution of the digital impression systems has no relationship with the accuracy they achieve in the impression of a complete dental arch. The study found that the Omnicam scanner is the system that obtains the best resolution, and that as the resolution increases, its precision increases. Key words:Trueness, precision, accuracy, resolution

  13. "Everyone just ate good food": 'Good food' in Islamabad, Pakistan.

    PubMed

    Hasnain, Saher

    2018-08-01

    In recent years, consumption of alternatively produced foods has increased in popularity in response to the deleterious effects of rapidly globalising and industrialised food systems. Concerns over food safety in relation to these changes may result from elevated levels of risk and changing perceptions associated with food production practices. This paper explores how the middle class residents of Islamabad, Pakistan, use the concept of 'good food' to reconnect themselves with nature, changing food systems, and traditional values. The paper also demonstrates how these ideas relate to those of organic, local, and traditional food consumption as currently used in more economically developed states in the Global North. Through research based on participant observation and semi-structured interviews, this paper illustrates that besides price and convenience, purity, freshness, association with specific places, and 'Pakistani-ness' were considered as the basis for making decisions about 'good food'. The results show that while individuals are aware of and have some access to imported organic and local food, they prefer using holistic and culturally informed concepts of 'good food' instead that reconnect them with food systems. I argue that through conceptualisations of 'good food', the urban middle class in Islamabad is reducing their disconnection and dis-embeddedness from nature, the food systems, and their social identities. The paper contributes to literature on food anxieties, reconnections in food geography, and 'good food' perceptions, with a focus on Pakistan. Copyright © 2018. Published by Elsevier Ltd.

  14. MAPPING SPATIAL THEMATIC ACCURACY WITH FUZZY SETS

    EPA Science Inventory

    Thematic map accuracy is not spatially homogenous but variable across a landscape. Properly analyzing and representing spatial pattern and degree of thematic map accuracy would provide valuable information for using thematic maps. However, current thematic map accuracy measures (...

  15. How Good Are Statistical Models at Approximating Complex Fitness Landscapes?

    PubMed Central

    du Plessis, Louis; Leventhal, Gabriel E.; Bonhoeffer, Sebastian

    2016-01-01

    Fitness landscapes determine the course of adaptation by constraining and shaping evolutionary trajectories. Knowledge of the structure of a fitness landscape can thus predict evolutionary outcomes. Empirical fitness landscapes, however, have so far only offered limited insight into real-world questions, as the high dimensionality of sequence spaces makes it impossible to exhaustively measure the fitness of all variants of biologically meaningful sequences. We must therefore revert to statistical descriptions of fitness landscapes that are based on a sparse sample of fitness measurements. It remains unclear, however, how much data are required for such statistical descriptions to be useful. Here, we assess the ability of regression models accounting for single and pairwise mutations to correctly approximate a complex quasi-empirical fitness landscape. We compare approximations based on various sampling regimes of an RNA landscape and find that the sampling regime strongly influences the quality of the regression. On the one hand it is generally impossible to generate sufficient samples to achieve a good approximation of the complete fitness landscape, and on the other hand systematic sampling schemes can only provide a good description of the immediate neighborhood of a sequence of interest. Nevertheless, we obtain a remarkably good and unbiased fit to the local landscape when using sequences from a population that has evolved under strong selection. Thus, current statistical methods can provide a good approximation to the landscape of naturally evolving populations. PMID:27189564

  16. The mathematical model accuracy estimation of the oil storage tank foundation soil moistening

    NASA Astrophysics Data System (ADS)

    Gildebrandt, M. I.; Ivanov, R. N.; Gruzin, AV; Antropova, L. B.; Kononov, S. A.

    2018-04-01

    The oil storage tanks foundations preparation technologies improvement is the relevant objective which achievement will make possible to reduce the material costs and spent time for the foundation preparing while providing the required operational reliability. The laboratory research revealed the nature of sandy soil layer watering with a given amount of water. The obtained data made possible developing the sandy soil layer moistening mathematical model. The performed estimation of the oil storage tank foundation soil moistening mathematical model accuracy showed the experimental and theoretical results acceptable convergence.

  17. Test Expectancy Affects Metacomprehension Accuracy

    ERIC Educational Resources Information Center

    Thiede, Keith W.; Wiley, Jennifer; Griffin, Thomas D.

    2011-01-01

    Background: Theory suggests that the accuracy of metacognitive monitoring is affected by the cues used to judge learning. Researchers have improved monitoring accuracy by directing attention to more appropriate cues; however, this is the first study to more directly point students to more appropriate cues using instructions regarding tests and…

  18. Accuracy of genomic prediction in switchgrass ( Panicum virgatum L.) improved by accounting for linkage disequilibrium

    DOE PAGES

    Ramstein, Guillaume P.; Evans, Joseph; Kaeppler, Shawn M.; ...

    2016-02-11

    Switchgrass is a relatively high-yielding and environmentally sustainable biomass crop, but further genetic gains in biomass yield must be achieved to make it an economically viable bioenergy feedstock. Genomic selection (GS) is an attractive technology to generate rapid genetic gains in switchgrass, and meet the goals of a substantial displacement of petroleum use with biofuels in the near future. In this study, we empirically assessed prediction procedures for genomic selection in two different populations, consisting of 137 and 110 half-sib families of switchgrass, tested in two locations in the United States for three agronomic traits: dry matter yield, plant height,more » and heading date. Marker data were produced for the families’ parents by exome capture sequencing, generating up to 141,030 polymorphic markers with available genomic-location and annotation information. We evaluated prediction procedures that varied not only by learning schemes and prediction models, but also by the way the data were preprocessed to account for redundancy in marker information. More complex genomic prediction procedures were generally not significantly more accurate than the simplest procedure, likely due to limited population sizes. Nevertheless, a highly significant gain in prediction accuracy was achieved by transforming the marker data through a marker correlation matrix. Our results suggest that marker-data transformations and, more generally, the account of linkage disequilibrium among markers, offer valuable opportunities for improving prediction procedures in GS. Furthermore, some of the achieved prediction accuracies should motivate implementation of GS in switchgrass breeding programs.« less

  19. Accuracy of genomic prediction in switchgrass ( Panicum virgatum L.) improved by accounting for linkage disequilibrium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramstein, Guillaume P.; Evans, Joseph; Kaeppler, Shawn M.

    Switchgrass is a relatively high-yielding and environmentally sustainable biomass crop, but further genetic gains in biomass yield must be achieved to make it an economically viable bioenergy feedstock. Genomic selection (GS) is an attractive technology to generate rapid genetic gains in switchgrass, and meet the goals of a substantial displacement of petroleum use with biofuels in the near future. In this study, we empirically assessed prediction procedures for genomic selection in two different populations, consisting of 137 and 110 half-sib families of switchgrass, tested in two locations in the United States for three agronomic traits: dry matter yield, plant height,more » and heading date. Marker data were produced for the families’ parents by exome capture sequencing, generating up to 141,030 polymorphic markers with available genomic-location and annotation information. We evaluated prediction procedures that varied not only by learning schemes and prediction models, but also by the way the data were preprocessed to account for redundancy in marker information. More complex genomic prediction procedures were generally not significantly more accurate than the simplest procedure, likely due to limited population sizes. Nevertheless, a highly significant gain in prediction accuracy was achieved by transforming the marker data through a marker correlation matrix. Our results suggest that marker-data transformations and, more generally, the account of linkage disequilibrium among markers, offer valuable opportunities for improving prediction procedures in GS. Furthermore, some of the achieved prediction accuracies should motivate implementation of GS in switchgrass breeding programs.« less

  20. Knowledge for the good of the individual and society: linking philosophy, disciplinary goals, theory, and practice.

    PubMed

    McCurry, Mary K; Revell, Susan M Hunter; Roy, Sr Callista

    2010-01-01

    Nursing as a profession has a social mandate to contribute to the good of society through knowledge-based practice. Knowledge is built upon theories, and theories, together with their philosophical bases and disciplinary goals, are the guiding frameworks for practice. This article explores a philosophical perspective of nursing's social mandate, the disciplinary goals for the good of the individual and society, and one approach for translating knowledge into practice through the use of a middle-range theory. It is anticipated that the integration of the philosophical perspective and model into nursing practice will strengthen the philosophy, disciplinary goal, theory, and practice links and expand knowledge within the discipline. With the focus on humanization, we propose that nursing knowledge for social good will embrace a synthesis of the individual and the common good. This approach converges vital and agency needs described by Hamilton and the primacy of maintaining the heritage of the good within the human species as outlined by Maritain. Further, by embedding knowledge development in a changing social and health care context, nursing focuses on the goals of clinical reasoning and action. McCubbin and Patterson's Double ABCX Model of Family Adaptation was used as an example of a theory that can guide practice at the community and global level. Using the theory-practice link as a foundation, the Double ABCX model provides practising nurses with one approach to meet the needs of individuals and society. The integration of theory into nursing practice provides a guide to achieve nursing's disciplinary goals of promoting health and preventing illness across the globe. When nursing goals are directed at the synthesis of the good of the individual and society, nursing's social and moral mandate may be achieved.

  1. Improved classification accuracy in 1- and 2-dimensional NMR metabolomics data using the variance stabilising generalised logarithm transformation

    PubMed Central

    Parsons, Helen M; Ludwig, Christian; Günther, Ulrich L; Viant, Mark R

    2007-01-01

    Background Classifying nuclear magnetic resonance (NMR) spectra is a crucial step in many metabolomics experiments. Since several multivariate classification techniques depend upon the variance of the data, it is important to first minimise any contribution from unwanted technical variance arising from sample preparation and analytical measurements, and thereby maximise any contribution from wanted biological variance between different classes. The generalised logarithm (glog) transform was developed to stabilise the variance in DNA microarray datasets, but has rarely been applied to metabolomics data. In particular, it has not been rigorously evaluated against other scaling techniques used in metabolomics, nor tested on all forms of NMR spectra including 1-dimensional (1D) 1H, projections of 2D 1H, 1H J-resolved (pJRES), and intact 2D J-resolved (JRES). Results Here, the effects of the glog transform are compared against two commonly used variance stabilising techniques, autoscaling and Pareto scaling, as well as unscaled data. The four methods are evaluated in terms of the effects on the variance of NMR metabolomics data and on the classification accuracy following multivariate analysis, the latter achieved using principal component analysis followed by linear discriminant analysis. For two of three datasets analysed, classification accuracies were highest following glog transformation: 100% accuracy for discriminating 1D NMR spectra of hypoxic and normoxic invertebrate muscle, and 100% accuracy for discriminating 2D JRES spectra of fish livers sampled from two rivers. For the third dataset, pJRES spectra of urine from two breeds of dog, the glog transform and autoscaling achieved equal highest accuracies. Additionally we extended the glog algorithm to effectively suppress noise, which proved critical for the analysis of 2D JRES spectra. Conclusion We have demonstrated that the glog and extended glog transforms stabilise the technical variance in NMR metabolomics

  2. Achieving behavioral control with millisecond resolution in a high-level programming environment.

    PubMed

    Asaad, Wael F; Eskandar, Emad N

    2008-08-30

    The creation of psychophysical tasks for the behavioral neurosciences has generally relied upon low-level software running on a limited range of hardware. Despite the availability of software that allows the coding of behavioral tasks in high-level programming environments, many researchers are still reluctant to trust the temporal accuracy and resolution of programs running in such environments, especially when they run atop non-real-time operating systems. Thus, the creation of behavioral paradigms has been slowed by the intricacy of the coding required and their dissemination across labs has been hampered by the various types of hardware needed. However, we demonstrate here that, when proper measures are taken to handle the various sources of temporal error, accuracy can be achieved at the 1 ms time-scale that is relevant for the alignment of behavioral and neural events.

  3. Achieving behavioral control with millisecond resolution in a high-level programming environment

    PubMed Central

    Asaad, Wael F.; Eskandar, Emad N.

    2008-01-01

    The creation of psychophysical tasks for the behavioral neurosciences has generally relied upon low-level software running on a limited range of hardware. Despite the availability of software that allows the coding of behavioral tasks in high-level programming environments, many researchers are still reluctant to trust the temporal accuracy and resolution of programs running in such environments, especially when they run atop non-real-time operating systems. Thus, the creation of behavioral paradigms has been slowed by the intricacy of the coding required and their dissemination across labs has been hampered by the various types of hardware needed. However, we demonstrate here that, when proper measures are taken to handle the various sources of temporal error, accuracy can be achieved at the one millisecond time-scale that is relevant for the alignment of behavioral and neural events. PMID:18606188

  4. SETI: A good introductory physics topic

    NASA Astrophysics Data System (ADS)

    Hobson, Art

    1997-04-01

    If America is to achieve the science literacy that is essential to industrialized democracy, all students must study such topics as scientific methodology, pseudoscience, ozone depletion, and global warming. My large-enrollment liberal-arts physics course covers the great principles of physics along with several such philosophical and societal topics. It is easy to include the interdisciplinary context of physics in courses for non-scientists, because these courses are flexible, conceptual, and taught to students whose interests span a broad range. Students find these topics relevant and fascinating, leading to large enrollments by non-scientists even in courses labeled ''physics.'' I will discuss my approach to teaching the search for extra-terrestrial intelligence (SETI), a topic with lots of good physics and with connections to scientific methodology and pseudoscience. A textbook for this kind of course has been published, Physics: Concepts and Connections (Prentice-Hall, 1995).

  5. Improving sub-grid scale accuracy of boundary features in regional finite-difference models

    USGS Publications Warehouse

    Panday, Sorab; Langevin, Christian D.

    2012-01-01

    As an alternative to grid refinement, the concept of a ghost node, which was developed for nested grid applications, has been extended towards improving sub-grid scale accuracy of flow to conduits, wells, rivers or other boundary features that interact with a finite-difference groundwater flow model. The formulation is presented for correcting the regular finite-difference groundwater flow equations for confined and unconfined cases, with or without Newton Raphson linearization of the nonlinearities, to include the Ghost Node Correction (GNC) for location displacement. The correction may be applied on the right-hand side vector for a symmetric finite-difference Picard implementation, or on the left-hand side matrix for an implicit but asymmetric implementation. The finite-difference matrix connectivity structure may be maintained for an implicit implementation by only selecting contributing nodes that are a part of the finite-difference connectivity. Proof of concept example problems are provided to demonstrate the improved accuracy that may be achieved through sub-grid scale corrections using the GNC schemes.

  6. Validation studies in forensic odontology - Part 1: Accuracy of radiographic matching.

    PubMed

    Page, Mark; Lain, Russell; Kemp, Richard; Taylor, Jane

    2018-05-01

    As part of a series of studies aimed at validating techniques in forensic odontology, this study aimed to validate the accuracy of ante-mortem (AM)/postmortem (PM) radiographic matching by dentists and forensic odontologists. This study used a web-based interface with 50 pairs of AM and PM radiographs from real casework, at varying degrees of difficulty. Participants were shown both radiographs as a pair and initially asked to decide if they represented the same individual using a yes/no binary choice forced-decision. Participants were asked to assess their level of confidence in their decision, and to make a conclusion using one of the ABFO (American Board of Forensic Odontology), INTERPOL (International Criminal Police Organisation) and DVISys™ (DVI System International, Plass Data Software) identification scale degrees. The mean false-positive rate using the binary choice scale was 12%. Overall accuracy was 89% using this model, however, 13% of participants scored below 80%. Only 25% of participants accurately answered yes or no >90% of the time, with no individual making the correct yes/no decision for all 50 pairs of radiographs. Non-odontologists (lay participants) scored poorly, with a mean accuracy of only 60%. Use of the graded ABFO, DVISYS and INTERPOL scales resulted in general improvements in performance, with the false-positive and false-negative rates falling to approximately 2% overall. Inter-examiner agreement in assigning scale degrees was good (ICC=0.64), however there was little correlation between confidence and both accuracy or agreement among practitioners. These results suggest that use of a non-binary scale is supported over a match/non-match call as it reduces the frequency of false positives and negatives. The use of the terms "possible" and "insufficient information" in the same scale appears to create confusion, reducing inter-examiner agreement. The lack of agreement between higher-performing and lower-performing groups suggests that

  7. Insensitivity of the octahedral spherical hohlraum to power imbalance, pointing accuracy, and assemblage accuracy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huo, Wen Yi; Zhao, Yiqing; Zheng, Wudi

    2014-11-15

    The random radiation asymmetry in the octahedral spherical hohlraum [K. Lan et al., Phys. Plasmas 21, 0 10704 (2014)] arising from the power imbalance, pointing accuracy of laser quads, and the assemblage accuracy of capsule is investigated by using the 3-dimensional view factor model. From our study, for the spherical hohlraum, the random radiation asymmetry arising from the power imbalance of the laser quads is about half of that in the cylindrical hohlraum; the random asymmetry arising from the pointing error is about one order lower than that in the cylindrical hohlraum; and the random asymmetry arising from the assemblage errormore » of capsule is about one third of that in the cylindrical hohlraum. Moreover, the random radiation asymmetry in the spherical hohlraum is also less than the amount in the elliptical hohlraum. The results indicate that the spherical hohlraum is more insensitive to the random variations than the cylindrical hohlraum and the elliptical hohlraum. Hence, the spherical hohlraum can relax the requirements to the power imbalance and pointing accuracy of laser facility and the assemblage accuracy of capsule.« less

  8. Accuracy of automated classification of major depressive disorder as a function of symptom severity.

    PubMed

    Ramasubbu, Rajamannar; Brown, Matthew R G; Cortese, Filmeno; Gaxiola, Ismael; Goodyear, Bradley; Greenshaw, Andrew J; Dursun, Serdar M; Greiner, Russell

    2016-01-01

    Growing evidence documents the potential of machine learning for developing brain based diagnostic methods for major depressive disorder (MDD). As symptom severity may influence brain activity, we investigated whether the severity of MDD affected the accuracies of machine learned MDD-vs-Control diagnostic classifiers. Forty-five medication-free patients with DSM-IV defined MDD and 19 healthy controls participated in the study. Based on depression severity as determined by the Hamilton Rating Scale for Depression (HRSD), MDD patients were sorted into three groups: mild to moderate depression (HRSD 14-19), severe depression (HRSD 20-23), and very severe depression (HRSD ≥ 24). We collected functional magnetic resonance imaging (fMRI) data during both resting-state and an emotional-face matching task. Patients in each of the three severity groups were compared against controls in separate analyses, using either the resting-state or task-based fMRI data. We use each of these six datasets with linear support vector machine (SVM) binary classifiers for identifying individuals as patients or controls. The resting-state fMRI data showed statistically significant classification accuracy only for the very severe depression group (accuracy 66%, p = 0.012 corrected), while mild to moderate (accuracy 58%, p = 1.0 corrected) and severe depression (accuracy 52%, p = 1.0 corrected) were only at chance. With task-based fMRI data, the automated classifier performed at chance in all three severity groups. Binary linear SVM classifiers achieved significant classification of very severe depression with resting-state fMRI, but the contribution of brain measurements may have limited potential in differentiating patients with less severe depression from healthy controls.

  9. Privacy-Preserving Accountable Accuracy Management Systems (PAAMS)

    NASA Astrophysics Data System (ADS)

    Thomas, Roshan K.; Sandhu, Ravi; Bertino, Elisa; Arpinar, Budak; Xu, Shouhuai

    We argue for the design of “Privacy-preserving Accountable Accuracy Management Systems (PAAMS)”. The designs of such systems recognize from the onset that accuracy, accountability, and privacy management are intertwined. As such, these systems have to dynamically manage the tradeoffs between these (often conflicting) objectives. For example, accuracy in such systems can be improved by providing better accountability links between structured and unstructured information. Further, accuracy may be enhanced if access to private information is allowed in controllable and accountable ways. Our proposed approach involves three key elements. First, a model to link unstructured information such as that found in email, image and document repositories with structured information such as that in traditional databases. Second, a model for accuracy management and entity disambiguation by proactively preventing, detecting and tracing errors in information bases. Third, a model to provide privacy-governed operation as accountability and accuracy are managed.

  10. Tracking accuracy assessment for concentrator photovoltaic systems

    NASA Astrophysics Data System (ADS)

    Norton, Matthew S. H.; Anstey, Ben; Bentley, Roger W.; Georghiou, George E.

    2010-10-01

    The accuracy to which a concentrator photovoltaic (CPV) system can track the sun is an important parameter that influences a number of measurements that indicate the performance efficiency of the system. This paper presents work carried out into determining the tracking accuracy of a CPV system, and illustrates the steps involved in gaining an understanding of the tracking accuracy. A Trac-Stat SL1 accuracy monitor has been used in the determination of pointing accuracy and has been integrated into the outdoor CPV module test facility at the Photovoltaic Technology Laboratories in Nicosia, Cyprus. Results from this work are provided to demonstrate how important performance indicators may be presented, and how the reliability of results is improved through the deployment of such accuracy monitors. Finally, recommendations on the use of such sensors are provided as a means to improve the interpretation of real outdoor performance.

  11. Simulation approach for the evaluation of tracking accuracy in radiotherapy: a preliminary study.

    PubMed

    Tanaka, Rie; Ichikawa, Katsuhiro; Mori, Shinichiro; Sanada, Sigeru

    2013-01-01

    Real-time tumor tracking in external radiotherapy can be achieved by diagnostic (kV) X-ray imaging with a dynamic flat-panel detector (FPD). It is important to keep the patient dose as low as possible while maintaining tracking accuracy. A simulation approach would be helpful to optimize the imaging conditions. This study was performed to develop a computer simulation platform based on a noise property of the imaging system for the evaluation of tracking accuracy at any noise level. Flat-field images were obtained using a direct-type dynamic FPD, and noise power spectrum (NPS) analysis was performed. The relationship between incident quantum number and pixel value was addressed, and a conversion function was created. The pixel values were converted into a map of quantum number using the conversion function, and the map was then input into the random number generator to simulate image noise. Simulation images were provided at different noise levels by changing the incident quantum numbers. Subsequently, an implanted marker was tracked automatically and the maximum tracking errors were calculated at different noise levels. The results indicated that the maximum tracking error increased with decreasing incident quantum number in flat-field images with an implanted marker. In addition, the range of errors increased with decreasing incident quantum number. The present method could be used to determine the relationship between image noise and tracking accuracy. The results indicated that the simulation approach would aid in determining exposure dose conditions according to the necessary tracking accuracy.

  12. Extended-Interval Gentamicin Dosing in Achieving Therapeutic Concentrations in Malaysian Neonates

    PubMed Central

    Tan, Sin Li; Wan, Angeline SL

    2015-01-01

    OBJECTIVE: To evaluate the usefulness of extended-interval gentamicin dosing practiced in neonatal intensive care unit (NICU) and special care nursery (SCN) of a Malaysian hospital. METHODS: Cross-sectional observational study with pharmacokinetic analysis of all patients aged ≤28 days who received gentamicin treatment in NICU/SCN. Subjects received dosing according to a regimen modified from an Australian-based pediatric guideline. During a study period of 3 months, subjects were evaluated for gestational age, body weight, serum creatinine concentration, gentamicin dose/interval, serum peak and trough concentrations, and pharmacokinetic parameters. Descriptive percentages were used to determine the overall dosing accuracy, while analysis of variance (ANOVA) was conducted to compare the accuracy rates among different gestational ages. Pharmacokinetic profile among different gestational age and body weight groups were compared by using ANOVA. RESULTS: Of the 113 subjects included, 82.3% (n = 93) achieved therapeutic concentrations at the first drug-monitoring assessment. There was no significant difference found between the percentage of term neonates who achieved therapeutic concentrations and the premature group (87.1% vs. 74.4%), p = 0.085. A total of 112 subjects (99.1%) achieved desired therapeutic trough concentration of <2 mg/L. Mean gentamicin peak concentration was 8.52 mg/L (95% confidence interval [Cl], 8.13–8.90 mg/L) and trough concentration was 0.54 mg/L (95% CI, 0.48–0.60 mg/L). Mean volume of distribution, half-life, and elimination rate were 0.65 L/kg (95% CI, 0.62–0.68 L/kg), 6.96 hours (95% CI, 6.52–7.40 hours), and 0.11 hour−1 (95% CI, 0.10–0.11 hour−1), respectively. CONCLUSION: The larger percentage of subjects attaining therapeutic range with extended-interval gentamicin dosing suggests that this regimen is appropriate and can be safely used among Malaysian neonates. PMID:25964729

  13. Automated and continual determination of radio telescope reference points with sub-mm accuracy: results from a campaign at the Onsala Space Observatory

    NASA Astrophysics Data System (ADS)

    Lösler, Michael; Haas, Rüdiger; Eschelbach, Cornelia

    2013-08-01

    The Global Geodetic Observing System (GGOS) requires sub-mm accuracy, automated and continual determinations of the so-called local tie vectors at co-location stations. Co-location stations host instrumentation for several space geodetic techniques and the local tie surveys involve the relative geometry of the reference points of these instruments. Thus, these reference points need to be determined in a common coordinate system, which is a particular challenge for rotating equipment like radio telescopes for geodetic Very Long Baseline Interferometry. In this work we describe a concept to achieve automated and continual determinations of radio telescope reference points with sub-mm accuracy. We developed a monitoring system, including Java-based sensor communication for automated surveys, network adjustment and further data analysis. This monitoring system was tested during a monitoring campaign performed at the Onsala Space Observatory in the summer of 2012. The results obtained in this campaign show that it is possible to perform automated determination of a radio telescope reference point during normal operations of the telescope. Accuracies on the sub-mm level can be achieved, and continual determinations can be realized by repeated determinations and recursive estimation methods.

  14. Accuracy of Monte Carlo simulations compared to in-vivo MDCT dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bostani, Maryam, E-mail: mbostani@mednet.ucla.edu; McMillan, Kyle; Cagnon, Chris H.

    Purpose: The purpose of this study was to assess the accuracy of a Monte Carlo simulation-based method for estimating radiation dose from multidetector computed tomography (MDCT) by comparing simulated doses in ten patients to in-vivo dose measurements. Methods: MD Anderson Cancer Center Institutional Review Board approved the acquisition of in-vivo rectal dose measurements in a pilot study of ten patients undergoing virtual colonoscopy. The dose measurements were obtained by affixing TLD capsules to the inner lumen of rectal catheters. Voxelized patient models were generated from the MDCT images of the ten patients, and the dose to the TLD for allmore » exposures was estimated using Monte Carlo based simulations. The Monte Carlo simulation results were compared to the in-vivo dose measurements to determine accuracy. Results: The calculated mean percent difference between TLD measurements and Monte Carlo simulations was −4.9% with standard deviation of 8.7% and a range of −22.7% to 5.7%. Conclusions: The results of this study demonstrate very good agreement between simulated and measured doses in-vivo. Taken together with previous validation efforts, this work demonstrates that the Monte Carlo simulation methods can provide accurate estimates of radiation dose in patients undergoing CT examinations.« less

  15. Accuracy assessment of Precise Point Positioning with multi-constellation GNSS data under ionospheric scintillation effects

    NASA Astrophysics Data System (ADS)

    Marques, Haroldo Antonio; Marques, Heloísa Alves Silva; Aquino, Marcio; Veettil, Sreeja Vadakke; Monico, João Francisco Galera

    2018-02-01

    GPS and GLONASS are currently the Global Navigation Satellite Systems (GNSS) with full operational capacity. The integration of GPS, GLONASS and future GNSS constellations can provide better accuracy and more reliability in geodetic positioning, in particular for kinematic Precise Point Positioning (PPP), where the satellite geometry is considered a limiting factor to achieve centimeter accuracy. The satellite geometry can change suddenly in kinematic positioning in urban areas or under conditions of strong atmospheric effects such as for instance ionospheric scintillation that may degrade satellite signal quality, causing cycle slips and even loss of lock. Scintillation is caused by small scale irregularities in the ionosphere and is characterized by rapid changes in amplitude and phase of the signal, which are more severe in equatorial and high latitudes geomagnetic regions. In this work, geodetic positioning through the PPP method was evaluated with integrated GPS and GLONASS data collected in the equatorial region under varied scintillation conditions. The GNSS data were processed in kinematic PPP mode and the analyses show accuracy improvements of up to 60% under conditions of strong scintillation when using multi-constellation data instead of GPS data alone. The concepts and analyses related to the ionospheric scintillation effects, the mathematical model involved in PPP with GPS and GLONASS data integration as well as accuracy assessment with data collected under ionospheric scintillation effects are presented.

  16. Voice Identification: Levels-of-Processing and the Relationship between Prior Description Accuracy and Recognition Accuracy.

    ERIC Educational Resources Information Center

    Walter, Todd J.

    A study examined whether a person's ability to accurately identify a voice is influenced by factors similar to those proposed by the Supreme Court for eyewitness identification accuracy. In particular, the Supreme Court has suggested that a person's prior description accuracy of a suspect, degree of attention to a suspect, and confidence in…

  17. Gender and Student Achievement in English Schools. CEE DP 58

    ERIC Educational Resources Information Center

    Machin, Stephen; McNally, Sandra

    2006-01-01

    In the UK, there is a marked gender gap in the educational attainment of boys and girls. At the end of compulsory education, 10 per cent fewer boys achieve 5 or more good GCSEs. This gap is by no means confined to GCSE. It is evident at all Key Stages. Furthermore, some indicators suggest that the gap has widened over time. In this paper, we…

  18. Evaluating the accuracy of orthophotos and 3D models from UAV photogrammetry

    NASA Astrophysics Data System (ADS)

    Julge, Kalev; Ellmann, Artu

    2015-04-01

    Rapid development of unmanned aerial vehicles (UAV) in recent years has made their use for various applications more feasible. This contribution evaluates the accuracy and quality of different UAV remote sensing products (i.e. orthorectified image, point cloud and 3D model). Two different autonomous fixed wing UAV systems were used to collect the aerial photographs. One is a mass-produced commercial UAV system, the other is a similar state-of-the-art UAV system. Three different study areas with varying sizes and characteristics (including urban areas, forests, fields, etc.) were surveyed. The UAV point clouds, 3D models and orthophotos were generated with three different commercial and free-ware software. The performance of each of these was evaluated. The effect of flying height on the accuracy of the results was explored, as well as the optimum number and placement of ground control points. Also the achieved results, when the only georeferencing data originates from the UAV system's on-board GNSS and inertial measurement unit, are investigated. Problems regarding the alignment of certain types of aerial photos (e.g. captured over forested areas) are discussed. The quality and accuracy of UAV photogrammetry products are evaluated by comparing them with control measurements made with GNSS-measurements on the ground, as well as high-resolution airborne laser scanning data and other available orthophotos (e.g. those acquired for large scale national mapping). Vertical comparisons are made on surfaces that have remained unchanged in all campaigns, e.g. paved roads. Planar comparisons are performed by control surveys of objects that are clearly identifiable on orthophotos. The statistics of these differences are used to evaluate the accuracy of UAV remote sensing. Some recommendations are given on how to conduct UAV mapping campaigns cost-effectively and with minimal time-consumption while still ensuring the quality and accuracy of the UAV data products. Also the

  19. The Effects of Direct Written Corrective Feedback on Improvement of Grammatical Accuracy of High-Proficient L2 Learners

    ERIC Educational Resources Information Center

    Farrokhi, Farahman; Sattarpour, Simin

    2012-01-01

    The present article reports the findings of a study that explored(1) whether direct written corrective feedback (CF) can help high-proficient L2 learners, who has already achieved a rather high level of accuracy in English, improve in the accurate use of two functions of English articles (the use of "a" for first mention and…

  20. A new ultra-high-accuracy angle generator: current status and future direction

    NASA Astrophysics Data System (ADS)

    Guertin, Christian F.; Geckeler, Ralf D.

    2017-09-01

    Lack of an extreme high-accuracy angular positioning device available in the United States has left a gap in industrial and scientific efforts conducted there, requiring certain user groups to undertake time-consuming work with overseas laboratories. Specifically, in x-ray mirror metrology the global research community is advancing the state-of-the-art to unprecedented levels. We aim to fill this U.S. gap by developing a versatile high-accuracy angle generator as a part of the national metrology tool set for x-ray mirror metrology and other important industries. Using an established calibration technique to measure the errors of the encoder scale graduations for full-rotation rotary encoders, we implemented an optimized arrangement of sensors positioned to minimize propagation of calibration errors. Our initial feasibility research shows that upon scaling to a full prototype and including additional calibration techniques we can expect to achieve uncertainties at the level of 0.01 arcsec (50 nrad) or better and offer the immense advantage of a highly automatable and customizable product to the commercial market.