Science.gov

Sample records for acremonium intraocular infection

  1. Fatal, disseminated Acremonium strictum infection in a neutropenic host.

    PubMed Central

    Schell, W A; Perfect, J R

    1996-01-01

    Disseminated Acremonium strictum infection in a neutropenic patient is reported. Positive fecal cultures preceded positive cutaneous and blood cultures by 18 and 21 days, respectively, which suggests gastrointestinal colonization and invasion as initiating events. Microscopic examination of cutaneous biopsy and pulmonary specimens revealed hyphae, phialides, and phialoconidia in vivo. These adventitious forms also can occur in infections due to other phialidic fungi such as Fusarium and Paecilomyces species and can be misdiagnosed as Candida species. Budding cells also can occur in vivo for species of Fusarium, Paecilomyces, and apparently Acremonium, further adding to the potential for misdiagnosis. The occurrence of adventitious forms in infections caused by species of Acremonium, Fusarium, Paecilomyces, Scedosporium, and Blastoschizomyces is suggested as a mechanism for dissemination of infection and as an explanation of the relatively higher frequency of positive blood cultures in these cases. PMID:8727935

  2. Modeling intraocular bacterial infections.

    PubMed

    Astley, Roger A; Coburn, Phillip S; Parkunan, Salai Madhumathi; Callegan, Michelle C

    2016-09-01

    Bacterial endophthalmitis is an infection and inflammation of the posterior segment of the eye which can result in significant loss of visual acuity. Even with prompt antibiotic, anti-inflammatory and surgical intervention, vision and even the eye itself may be lost. For the past century, experimental animal models have been used to examine various aspects of the pathogenesis and pathophysiology of bacterial endophthalmitis, to further the development of anti-inflammatory treatment strategies, and to evaluate the pharmacokinetics and efficacies of antibiotics. Experimental models allow independent control of many parameters of infection and facilitate systematic examination of infection outcomes. While no single animal model perfectly reproduces the human pathology of bacterial endophthalmitis, investigators have successfully used these models to understand the infectious process and the host response, and have provided new information regarding therapeutic options for the treatment of bacterial endophthalmitis. This review highlights experimental animal models of endophthalmitis and correlates this information with the clinical setting. The goal is to identify knowledge gaps that may be addressed in future experimental and clinical studies focused on improvements in the therapeutic preservation of vision during and after this disease. PMID:27154427

  3. Voriconazole curative treatment for Acremonium species keratitis developed in a patient with concomitant Staphylococcus aureus corneal infection: a case report.

    PubMed

    Cretì, Anna; Esposito, Vincenzo; Bocchetti, Maria; Baldi, Gianluca; De Rosa, Pasquale; Parrella, Roberto; Chirianni, Antonio

    2006-01-01

    The case of a 49-year-old male Caucasian, with more than a 3-year history of recurrent keratoconjunctivitis treated with steroids, antibiotics and midriatics, is reported. A combined Acremonium spp. and S. aureus infection was detected. After unsuccessful therapy with fluconazole, the Acremonium spp. infection was eradicated by voriconazole treatment. To our knowledge, this is the first case report of complete regression of this kind of infection by the use of voriconazole. Therefore, we strongly recommend, in the event of a compatible clinical picture, laboratory testing for mycetes even in the absence of traumatic events, and the use of the new generation azoles, in order avoid a keratoplasty intervention and disease progression to severe endophthalmitis. PMID:16433048

  4. Acremonium Pneumonia: Case Report and Literature Review

    PubMed Central

    Fakharian, Atefeh; Dorudinia, Atosa; Mansouri, Davood; Masjedi, Mohammad Reza

    2015-01-01

    Acremonium spp. cause human superficial infections including mycetoma, onychomycosis and keratitis. There are a few reports of systemic involvement in immunocompromised patients. However, isolated pulmonary infection in otherwise healthy hosts has never been reported in the literature. Herein, we report a 59 year-old diabetic man with non-resolving pneumonia due to Acremonium spp. and provide a consensus review of the published clinical cases of systemic and respiratory tract infections. PMID:26528372

  5. Bacterial Spectrum and Antibiotic Resistance Patterns of Ocular Infection: Differences between External and Intraocular Diseases

    PubMed Central

    Wang, Nan; Yang, Qian; Tan, Yiwei; Lin, Liping; Huang, Qiang; Wu, Kaili

    2015-01-01

    This study aimed to compare the differences of microbial spectrum and antibiotic resistance patterns between external and intraocular bacterial infections in an eye hospital in South China. A total of 737 bacteria isolates from suspected ocular infections were included in this retrospective study covering the period 2010–2013. The organisms cultured from the ocular surface (cornea, conjunctiva) accounted for the majority of the isolates (82.77%, n = 610), followed by the intraocular (aqueous humor, vitreous fluid), which accounted for 17.23% (n = 127). The top three species accounting for the external ocular infections were S. epidermidis (35.25%), P. aeruginosa (8.03%), and S. simulans (4.43%). The top three species for the intraocular infections were S. epidermidis (14.96%), S. hominis (8.66%), and B. subtilis (7.87%). The bacteria from the external ocular surface were more sensitive to neomycin, while those from the intraocular specimens were more sensitive to levofloxacin (P < 0.01). Multidrug resistance was found in 89 bacteria (12.08%), including isolates from both external (13.28%) and intraocular samples (6.30%). The results of this study indicate that the bacteria spectrum of external and intraocular infections is variable in the setting. A high percentage of bacterial organisms were found to be primarily susceptible to neomycin for external infection and levofloxacin for intraocular infection. PMID:26576294

  6. Role of TLR5 and flagella in bacillus intraocular infection.

    PubMed

    Parkunan, Salai Madhumathi; Astley, Roger; Callegan, Michelle C

    2014-01-01

    B. cereus possesses flagella which allow the organism to migrate within the eye during a blinding form of intraocular infection called endophthalmitis. Because flagella is a ligand for Toll-like receptor 5 (TLR5), we hypothesized that TLR5 contributed to endophthalmitis pathogenesis. Endophthalmitis was induced in C57BL/6J and TLR5-/- mice by injecting 100 CFU of B. cereus into the mid-vitreous. Eyes were analyzed for intraocular bacterial growth, retinal function, and inflammation by published methods. Purified B. cereus flagellin was also injected into the mid-vitreous of wild type C57BL/6J mice and inflammation was analyzed. TLR5 activation by B. cereus flagellin was also analyzed in vitro. B. cereus grew rapidly and at similar rates in infected eyes of C57BL/6J and TLR5-/- mice. A significant loss in retinal function in both groups of mice was observed at 8 and 12 hours postinfection. Retinal architecture disruption and acute inflammation (neutrophil infiltration and proinflammatory cytokine concentrations) increased and were significant at 8 and 12 hours postinfection. Acute inflammation was comparable in TLR5-/- and C57BL/6J mice. Physiological concentrations of purified B. cereus flagellin caused significant inflammation in C57BL/6J mouse eyes, but not to the extent of that observed during active infection. Purified B. cereus flagellin was a weak agonist for TLR5 in vitro. These results demonstrated that the absence of TLR5 did not have a significant effect on the evolution of B. cereus endophthalmitis. This disparity may be due to sequence differences in important TLR5 binding domains in B. cereus flagellin or the lack of flagellin monomers in the eye to activate TLR5 during infection. Taken together, these results suggest a limited role for flagellin/TLR5 interactions in B. cereus endophthalmitis. Based on this and previous data, the importance of flagella in this disease lies in its contribution to the motility of the organism within the eye during

  7. Evaluation of the Efficacies of Amphotericin B, Posaconazole, Voriconazole, and Anidulafungin in a Murine Disseminated Infection by the Emerging Opportunistic Fungus Sarocladium (Acremonium) kiliense

    PubMed Central

    Fernández-Silva, Fabiola; Capilla, Javier; Mayayo, Emilio; Sutton, Deanna A.; Hernández, Pilar

    2013-01-01

    We evaluated and compared the efficacies of different antifungal drugs against Sarocladium kiliense (formerly Acremonium kiliense), a clinically relevant opportunistic fungus, in a murine model of systemic infection. Three clinical strains of this fungus were tested, and the therapy administered was as follows: posaconazole at 20 mg/kg of body weight (twice daily), voriconazole at 40 mg/kg, anidulafungin at 10 mg/kg, or amphotericin B at 0.8 mg/kg. The efficacy was evaluated by prolonged animal survival, tissue burden reduction, and (1→3)-β-d-glucan serum levels. In general, the four antifungal drugs showed high MICs and poor in vitro activity. The efficacy of the different treatments was only modest, since survival rates were never higher than 40% and no drug was able to reduce fungal load in all the organs for the three strains tested. Posaconazole, in spite of its high MICs (≥16 μg/ml), showed the highest efficacy. The (1→3)-β-d-glucan serum levels were equally reduced by all drugs evaluated. PMID:24100490

  8. Role of intraocular Leptospira infections in the pathogenesis of Equine Recurrent Uveitis in the Southern United States

    Technology Transfer Automated Retrieval System (TEKTRAN)

    To investigate the role of intraocular leptospiral infections in horses with Equine Recurrent Uveitis (ERU) in the southern United States, blood and ocular fluid samples were collected from horses with a history and ocular findings consistent with ERU. Samples were also obtained from control horses ...

  9. Unexpected Roles for Toll-Like Receptor 4 and TRIF in Intraocular Infection with Gram-Positive Bacteria

    PubMed Central

    Parkunan, Salai Madhumathi; Randall, C. Blake; Coburn, Phillip S.; Astley, Roger A.; Staats, Rachel L.

    2015-01-01

    Inflammation caused by infection with Gram-positive bacteria is typically initiated by interactions with Toll-like receptor 2 (TLR2). Endophthalmitis, an infection and inflammation of the posterior segment of the eye, can lead to vision loss when initiated by a virulent microbial pathogen. Endophthalmitis caused by Bacillus cereus develops as acute inflammation with infiltrating neutrophils, and vision loss is potentially catastrophic. Residual inflammation observed during B. cereus endophthalmitis in TLR2−/− mice led us to investigate additional innate pathways that may trigger intraocular inflammation. We first hypothesized that intraocular inflammation during B. cereus endophthalmitis would be controlled by MyD88- and TRIF-mediated signaling, since MyD88 and TRIF are the major adaptor molecules for all bacterial TLRs. In MyD88−/− and TRIF−/− mice, we observed significantly less intraocular inflammation than in eyes from infected C57BL/6J mice, suggesting an important role for these TLR adaptors in B. cereus endophthalmitis. These results led to a second hypothesis, that TLR4, the only TLR that signals through both MyD88 and TRIF signaling pathways, contributed to inflammation during B. cereus endophthalmitis. Surprisingly, B. cereus-infected TLR4−/− eyes also had significantly less intraocular inflammation than infected C57BL/6J eyes, indicating an important role for TLR4 in B. cereus endophthalmitis. Taken together, our results suggest that TLR4, TRIF, and MyD88 are important components of the intraocular inflammatory response observed in experimental B. cereus endophthalmitis, identifying a novel innate immune interaction for B. cereus and for this disease. PMID:26195555

  10. Analysis of phylogenetic relationship of Cylindrocarpon lichenicola and Acremonium falciforme to the Fusarium solani species complex and a review of similarities in the spectrum of opportunistic infections caused by these fungi.

    PubMed

    Summerbell, R C; Schroers, H-J

    2002-08-01

    An emerging pattern of similarity in medical case reports led to a project to compare the phylogenetic affinities of two well-known tropical fungal opportunistic pathogens, Cylindrocarpon lichenicola and Acremonium falciforme, to members of the Fusarium solani species complex. C. lichenicola and A. falciforme, despite their deviating conidial morphologies, were shown via sequencing of the ribosomal large subunit to be well instituted within a clade mainly consisting of typical F. solani strains and other species until recently considered variants of F. solani. The original name Fusarium lichenicola C. B. Massalongo is reestablished, and the new combination F. falciforme is made. Recognition of these species as fusaria is necessary for correct interpretation of current and future molecular diagnostic tests. Reevaluation of species morphology in light of the molecular findings showed that certain features, especially elongate filiform conidiophores with integrated terminal phialides, facilitate correct microscopic classification of these atypical Fusarium species. There is a strong and underrecognized overlap in the spectra of cases caused by members of the F. solani clade, particularly ocular infections, mycetomas, and, in the neutropenic host, disseminated and other serious systemic infections. A novel synthesis of case reports shows that patients from areas with warm climates may develop a distinctive fusarial intertrigo caused by F. solani, Fusarium lichenicola, or Fusarium oxysporum. PMID:12149344

  11. Prevalence and factors predictive of intraocular fungal infection in patients with fungemia at an academic urban tertiary care center

    PubMed Central

    Geraymovych, Elena; Conduff, Joseph H; Braich, Puneet S; Leffler, Christopher T; Brar, Vikram S

    2015-01-01

    Objective To report the prevalence and to identify factors predictive of intraocular infection in patients with fungemia receiving prophylactic antifungal therapy. Methods A retrospective review of patients who received prophylactic antifungal therapy and a dilated fundus examination at an academic urban tertiary care center from 2000 to 2007. Basic demographic information, fungal species grown, antifungal agent(s) used, number of positive blood culture specimens, visual acuity, visual symptoms, and known risks of disseminated candidiasis were noted. Logistic regression analysis was used to determine the factors significantly associated with intraocular fungal infection. Results A total of 132 patients with positive fungemia culture were requested to have ophthalmology consults. The prevalence of ocular infection was 6.9% (N=9). All nine patients were infected with Candida species. Undergoing gastrointestinal (GI) surgery within the prior 6 months was significantly related to developing intraocular infection, with an odds ratio of 18.5 (95% confidence interval, 15.1–24.3; P=0.002). Having ≥3 positive fungal blood cultures was also a significant risk factor, with an odds ratio of 2.6 (95% confidence interval, 1.8–3.7; P=0.03). Among 40 patients having GI surgery, eight (20.0%) had intraocular fungal disease, compared with one of 92 patients (1.1%) not having GI surgery. Among 125 patients with a negative baseline examination result, two of 32 patients (6.3%), who had recent GI surgery, subsequently developed fungal ocular disease, compared with 0 of 93 patients (0%), who did not have recent GI surgery. Conclusion Recent GI surgery and higher numbers of positive fungal blood culture specimens may be predictive of candida ocular infections. Normal baseline fundoscopy examination results in patients with such risks may require repeat evaluations to detect delayed manifestations. PMID:26491246

  12. A GOOD ENDOPHYTE OF MAIZE: ACREMONIUM ZEAE ANTIBIOTICS INHIBITORY TO ASPERGILLUS FLAVUS AND FUSARIUM VERTICILLIOIDES

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The maize endophyte Acremonium zeae Gams and Sumner is antagonistic to kernel rotting and mycotoxin producing fungi Aspergillus flavus and Fusarium verticillioides in cultural tests for antagonism and interferes with A. flavus infection and aflatoxin contamination of preharvest maize kernels. Chemi...

  13. Pseudo-outbreak of Lecanicillium and Acremonium species in orthopedic surgery patients.

    PubMed

    Neal, Carolyn O S; Deak, Eszter; Chang, Loretta S; Gilmartin, Heather; Gade, Lalitha; Imanishi, Maho; Price, Connie; Brandt, Mary E; Chiller, Tom; Balajee, S Arunmozhi

    2012-12-01

    Acremonium species cause a variety of human infections, while Lecanicillium species have not been reported as human pathogens. We describe a pseudo-outbreak involving both organisms, highlighting the role and limitations of molecular methods in the characterization of rare fungal isolates. Repeated isolation of these fungi from patient tissue samples raises concerns about exogenous contamination in the hospital environment. PMID:23015668

  14. Bacterial endophthalmitis in the age of outpatient intravitreal therapies and cataract surgeries: Host-microbe interactions in intraocular infection

    PubMed Central

    Sadaka, Ama; Durand, Marlene L; Gilmore, Michael S

    2012-01-01

    Bacterial endophthalmitis is a sight threatening infection of the interior structures of the eye. Incidence in the US has increased in recent years, which appears to be related to procedures being performed on an aging population. The advent of outpatient intravitreal therapy for management of age-related macular degeneration raises yet additional risks. Compounding the problem is the continuing progression of antibiotic resistance. Visual prognosis for endophthalmitis depends on the virulence of the causative organism, the severity of intraocular inflammation, and the timeliness of effective therapy. We review the current understanding of the pathogenesis of bacterial endophthalmitis, highlighting opportunities for the development of improved therapeutics and preventive strategies. PMID:22521570

  15. Bacterial endophthalmitis in the age of outpatient intravitreal therapies and cataract surgeries: host-microbe interactions in intraocular infection.

    PubMed

    Sadaka, Ama; Durand, Marlene L; Gilmore, Michael S

    2012-07-01

    Bacterial endophthalmitis is a sight threatening infection of the interior structures of the eye. Incidence in the US has increased in recent years, which appears to be related to procedures being performed on an aging population. The advent of outpatient intravitreal therapy for management of age-related macular degeneration raises yet additional risks. Compounding the problem is the continuing progression of antibiotic resistance. Visual prognosis for endophthalmitis depends on the virulence of the causative organism, the severity of intraocular inflammation, and the timeliness of effective therapy. We review the current understanding of the pathogenesis of bacterial endophthalmitis, highlighting opportunities for the development of improved therapeutics and preventive strategies. PMID:22521570

  16. Mycetoma Caused by Acremonium Species in a Patient with Chronic Granulomatous Disease

    PubMed Central

    Wong, Gabriel; Jones, Julie; Huissoon, Aarnoud

    2016-01-01

    Patients with chronic granulomatous disease are predisposed to fungal infections and are therefore routinely prescribed antifungal prophylaxis. We report a case where acremonium was responsible for causing a cutaneous infection (mycetoma) despite antifungal prophylaxis. Treatment with voriconazole was initiated and the infection gradually resolved. This case highlights the need for careful clinical follow-up and thorough investigation of patients who have a neutrophil immunodeficiency. PMID:27022493

  17. Acremonium phylogenetic overview and revision of Gliomastix, Sarocladium, and Trichothecium.

    PubMed

    Summerbell, R C; Gueidan, C; Schroers, H-J; de Hoog, G S; Starink, M; Rosete, Y Arocha; Guarro, J; Scott, J A

    2011-01-01

    Over 200 new sequences are generated for members of the genus Acremonium and related taxa including ribosomal small subunit sequences (SSU) for phylogenetic analysis and large subunit (LSU) sequences for phylogeny and DNA-based identification. Phylogenetic analysis reveals that within the Hypocreales, there are two major clusters containing multiple Acremonium species. One clade contains Acremonium sclerotigenum, the genus Emericellopsis, and the genus Geosmithia as prominent elements. The second clade contains the genera Gliomastixsensu stricto and Bionectria. In addition, there are numerous smaller clades plus two multi-species clades, one containing Acremonium strictum and the type species of the genus Sarocladium, and, as seen in the combined SSU/LSU analysis, one associated subclade containing Acremonium breve and related species plus Acremonium curvulum and related species. This sequence information allows the revision of three genera. Gliomastix is revived for five species, G. murorum, G. polychroma, G. tumulicola, G. roseogrisea, and G. masseei. Sarocladium is extended to include all members of the phylogenetically distinct A. strictum clade including the medically important A. kiliense and the protective maize endophyte A. zeae. Also included in Sarocladium are members of the phylogenetically delimited Acremonium bacillisporum clade, closely linked to the A. strictum clade. The genus Trichothecium is revised following the principles of unitary nomenclature based on the oldest valid anamorph or teleomorph name, and new combinations are made in Trichothecium for the tightly interrelated Acremonium crotocinigenum, Spicellum roseum, and teleomorph Leucosphaerinaindica. Outside the Hypocreales, numerous Acremonium-like species fall into the Plectosphaerellaceae, and A. atrogriseum falls into the Cephalothecaceae. PMID:21523192

  18. Acremonium phylogenetic overview and revision of Gliomastix, Sarocladium, and Trichothecium

    PubMed Central

    Summerbell, R.C.; Gueidan, C.; Schroers, H-J.; de Hoog, G.S.; Starink, M.; Rosete, Y. Arocha; Guarro, J.; Scott, J.A.

    2011-01-01

    Over 200 new sequences are generated for members of the genus Acremonium and related taxa including ribosomal small subunit sequences (SSU) for phylogenetic analysis and large subunit (LSU) sequences for phylogeny and DNA-based identification. Phylogenetic analysis reveals that within the Hypocreales, there are two major clusters containing multiple Acremonium species. One clade contains Acremonium sclerotigenum, the genus Emericellopsis, and the genus Geosmithia as prominent elements. The second clade contains the genera Gliomastix sensu stricto and Bionectria. In addition, there are numerous smaller clades plus two multi-species clades, one containing Acremonium strictum and the type species of the genus Sarocladium, and, as seen in the combined SSU/LSU analysis, one associated subclade containing Acremonium breve and related species plus Acremonium curvulum and related species. This sequence information allows the revision of three genera. Gliomastix is revived for five species, G. murorum, G. polychroma, G. tumulicola, G. roseogrisea, and G. masseei. Sarocladium is extended to include all members of the phylogenetically distinct A. strictum clade including the medically important A. kiliense and the protective maize endophyte A. zeae. Also included in Sarocladium are members of the phylogenetically delimited Acremonium bacillisporum clade, closely linked to the A. strictum clade. The genus Trichothecium is revised following the principles of unitary nomenclature based on the oldest valid anamorph or teleomorph name, and new combinations are made in Trichothecium for the tightly interrelated Acremonium crotocinigenum, Spicellum roseum, and teleomorph Leucosphaerina indica. Outside the Hypocreales, numerous Acremonium-like species fall into the Plectosphaerellaceae, and A. atrogriseum falls into the Cephalothecaceae. PMID:21523192

  19. [Tropical ophthalmology : Intraocular inflammation caused by "new" infectious pathogens and travel-related infections].

    PubMed

    Pleyer, U; Klauß, V; Wilking, H; Nentwich, M M

    2016-01-01

    A number of "new" (emerging) infections that can also cause inflammatory eye changes are appearing and becoming increasingly important. In the past, diseases such as chikungunya, dengue fever or West Nile virus infections were endemic in tropical regions, but are now expanding worldwide and causing significant morbidity and even mortality. "Globalization" and human migration are important factors leading to the import of these infections. Climate changes are probably even more important. Increasing temperatures provide suitable conditions for new vectors, and may lead to autochthonous transmission of infectious pathogens. Diagnosis of these diseases requires not only careful assessment of medical and travel history, but also the application of specific laboratory diagnostic tests. A broad spectrum of ocular involvement has been reported, with frequent posterior segment involvement. Emerging infections should therefore be considered in the differential diagnosis of retinitis, chorioretinitis, retinal vasculitis and optic neuropathy in a patient living in or traveling back from an endemic area. Since these infections are often vector (insect) borne and effective treatments are almost uniformly lacking, prevention is at least as important as prompt diagnosis and initiation of supportive care. Here, we focus on Chikungunya, Dengue fever, Ebola fever, the West Nile virus and Rickettsioses, which frequently demonstrate ocular involvement. PMID:26649438

  20. Characterization of Acremonium and Isaria ice nuclei

    NASA Astrophysics Data System (ADS)

    Pummer, Bernhard G.; Pöschl, Ulrich; Fröhlich-Nowoisky, Janine

    2014-05-01

    Until recently, the only known fungal ice nuclei (IN) were a few exponents of lichen mycobionts and Fusarium spp. [Kieft and Ruscetti 1990, Pouleur et al. 1992, Hasegawa et al. 1994, Tsumuki et al. 1995], as well as two strains of mold [Jayaweera and Flanagan 1982]. Other investigated species did not show any IN activity [Pouleur et al. 1992, Iannone et al. 2011, Pummer et al. 2013]. In the last few years, IN-activity has been discovered in some rust and smut fungi [Morris et al. 2013, Haga et al. 2013], Acremonium implicatum (Acr.) and Isaria farinosa (Isa.) [Huffman et al. 2013] and a handful of other airborne and soil fungi [unpublished data]. We started characterizing the IN of Acr. and Isa.: Like other non-bacterial biological IN, they can be easily separated from the cells in aqueous suspension, and keep their activity. The IN-active aqueous suspensions were processed by filtration (5 μm, 0.1 μm, 300 kDa, 100 kDa) and exposure to heat (60° C) or guanidinium chloride (6 M). The IN activity of the processed samples was measured by a freezing assay of droplets, as described by Pummer et al. [2013]. Via the Vali formula, we calculated the amount of IN per gram of mycelium, which is higher than 105 g-1. The initial freezing temperature was -4° C for Isaria and -8° C for Acremonium IN. Both were completely knocked out by 60° C or guanidinium chloride. The Acremonium IN are in a mass range between 100 and 300 kDa. The Isaria IN seem to be either a bit larger, or more attached to larger particles, since not all of them pass through the 300-kDa-filter. It is likely that both of these new IN are proteinaceous like the IN of Fusarium spp. and lichen mycobionts, which belong to the Ascomycota phylum. Since the Isaria IN show a high onset freezing temperature and are rather large for single molecules, they might be agglomerates. Haga D.I. et al. (2013) J. Geophys. Res.: Atm. 118, 7260-7272 Hasegawa Y. et al. (1994) Biosci. Biotech. Biochem. 58, 2273-2274 Huffman A

  1. TGF-β1 levels and intraocular tissue alterations in mice infected with a virulent type I RH Toxoplasma gondii strain.

    PubMed

    Iqbal, Jamshaid; Al-Awadhi, Mohammad Ahmed; Raghupathy, Raj Gopal

    2016-03-01

    Toxoplasmosis is generally self-limiting in healthy adults but it may cause toxoplasmic retinochoroiditis in cases of congenital infection leading to blindness. The importance of host genetics in determining disease severity in ocular toxoplasmosis has been shown in different inbred mouse strains using low-virulence toxoplasma strain. In this study, we studied intraocular immune response and tissue alterations in the genetically resistant BALB/c and susceptible MF1 mice infected with a virulent type I RH Toxoplasma gondii strain by intravitreal route. We observed a significant up-regulation of IFN-γ and TNF-α to >2200 pg/ml and >300 pg/ml respectively in the blood of both BALB/c and MF1mice during the early stages of post intraocular infection (p < 0.01) but the levels dropped sharply to normal during the late stages of the infection on day 26. The cytokine levels detected were higher in the MF1 mice compared with the BALB/c mice and a relatively higher levels were observed in the aqueous humour (AqH) than in the blood of both group of mice. The TGF-β1 level in the blood and AqH of BALB/c mice remained low throughout the infection period compared with MF1 mice which showed gradual increase to 50 pg/ml in the blood and AqH during the early stages of infection which then further increased 2-fold-132 pg/ml on day 11 (p < 0.01) and remained high till the last day of observation on day 26 except that the TGF-β1 level in AqH dropped sharply to normal level. In summary, our results support that TGF-β1 may down-regulate the effector functions of anti-Toxoplasma cellular immunity during acute toxoplasmosis. We document that a mild Th1 pro-inflammatory response in the BALB/c mice with high IFN-γ and TNF-α and, low TGF-β1 levels during the early stages of infection may have contributed to an effective cellular immune response leading to lower morbidity, mortality and less ocular tissue damage. However in the MF1 mice, a significantly high TGF-β1 level in the blood as

  2. [Intraocular neovascularization].

    PubMed

    Inomata, H; Ishibashi, T; Murata, T; Iwasaki, M; Tahara, A; Hata, K; Yoshida, A; Yoshida, S; Onishi, Y; Murakami, M; Yamamoto, M; Kubota, T; Kawano, Y; Sugai, S; Sakamoto, T; Okada, T; Ishimoto, S; Fujisawa, K; Honda, T; Sakamoto, M; Shigefuji, M; Tsuji, I; Nishioka, K; Ueno, A; Nagatomi, Y

    1997-12-01

    To investigate the mechanism of intraocular neovascularization, we studied how vascular endothelial growth factor (VEGF) and interleukin-8 (IL-8) are expressed in the ocular tissues under hypoxic conditions. Prior to proliferation of vascular endothelial cells resulting in neovascularization, the retinal tissues such as pericytes, retinal glial cells, ganglion cells, and ciliary epithelium react directly to hypoxia expressing VEGF and/or IL-8 and stimulate endothelial cell proliferation in a paracrine manner. We demonstrated that transcription factor activator protein-1 (AP-1) is activated for expression of VEGF messenger ribonuculeic acid (mRNA) and in a similar way nuclear factor kappa B (NF-kappa B) is activated for expression of IL-8 mRNA. However, hypoxia-induced expression of VEGF and/ or IL-8 is only one aspect of the complicated processes in intraocular neovascularization. We hope that further detailed analysis of the mechanism will make it possible to inhibit and treat clinically intraocular neovascularization in the near future. PMID:9436356

  3. Phakic Intraocular Lenses

    MedlinePlus

    ... Implants and Prosthetics Phakic Intraocular Lenses Phakic Intraocular Lenses Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Phakic intraocular lenses are new devices used to correct nearsightedness. These ...

  4. Cellulases and hemicellulases from endophytic Acremonium species and its application on sugarcane bagasse hydrolysis

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The aim of this work was to have cellulase activity and hemicellulase activity screenings of endophyte Acremonium species (Acremonium zeae EA0802 and Acremonium sp. EA0810). Both fungi were cultivated in submerged culture (SC) containing L-arabinose, D-xylose, oat spelt xylan, sugarcane bagasse, or...

  5. A protective endophyte of maize: Acremonium zeae antibiotics inhibitory to Aspergillus flavus and Fusarium verticillioides.

    PubMed

    Wicklow, Donald T; Roth, Shoshannah; Deyrup, Stephen T; Gloer, James B

    2005-05-01

    The maize endophyte Acremonium zeae is antagonistic to kernel rotting and mycotoxin producing fungi Aspergillus flavus and Fusarium verticillioides in cultural tests for antagonism, and interferes with A. flavus infection and aflatoxin contamination of preharvest maize kernels. Chemical studies of an organic extract from maize kernel fermentations of Acremonium zeae (NRRL 13540), which displayed significant antifungal activity against Aspergillus flavus and F. verticillioides, revealed that the metabolites accounting for this activity were two newly reported antibiotics pyrrocidines A and B. Pyrrocidines were detected in fermentation extracts for 12 NRRL cultures of Acremonium zeae isolated from maize kernels harvested in Illinois (4/4 cultures), North Carolina (5/5), Georgia (1/2) and unrecorded locations within the USA (2/2). Pyrrocidine B was detected by LCMSMS in whole symptomatic maize kernels removed at harvest from ears of a commercial hybrid that were wound-inoculated in the milk stage with A. zeae (NRRL 13540) or (NRRL 13541). The pyrrocidines were first reported from the fermentation broth of an unidentified filamentous fungus LL-Cyan426, isolated from a mixed Douglas Fir hardwood forest on Crane Island Preserve, Washington, in 1993. Pyrrocidine A exhibited potent activity against most Gram-positive bacteria, including drug-resistant strains, and was also active against the yeast Candida albicans. In an evaluation of cultural antagonism between 13 isolates of A. zeae in pairings with A. flavus (NRRL 6541) and F. verticillioides (NRRL 25457), A. zeae (NRRL 6415) and (NRRL 34556) produced the strongest reaction, inhibiting both organisms at a distance while continuing to grow through the resulting clear zone at an unchanged rate. Maximum colony diameters for A. zeae (NRRL 6415) and (NRRL 13540), on potato dextrose agar after 14 d, were attained within the range of 25-30 degrees C, with less growth recorded at 15 degrees and 37.5 degrees and no growth at 5

  6. Clinical experiences in fungal keratitis caused by Acremonium

    PubMed Central

    Kim, Seong-Jae; Cho, Yong-Wun; Seo, Seong-Wook; Kim, Sun-Joo; Yoo, Ji-Myong

    2014-01-01

    Purpose To report the predisposing risk factors, clinical presentation, management, and therapeutic outcomes of fungal keratitis caused by Acremonium. Methods This is a retrospective study of cases with Acremonium fungal keratitis that presented to our tertiary referral center between January 2006 and August 2012. Patient demographic and clinical details were determined and reported. Results Five cases of fungal keratitis from Acremonium species were identified in five patients (three males, two females). The mean age of the patients was of 73.4±5.46 years, with a mean follow-up time of 124±72 days. All patients had a history of corneal trauma with vegetable matter. Four cases were unresponsive to initial treatment (0.2% fluconazole, 0.15% amphotericin B) and required topical 5% natamycin, and, in two out of five cases, topical 1% voriconazole. Conclusion The most common risk factors for Acremonium fungal keratitis was ocular trauma. When a corneal lesion is found to be unresponsive to the initial treatment, we should consider adding or substituting topical natamycin or voriconazole for treatment. PMID:24492439

  7. Extracellular Hemicellulolytic Enzymes from the Maize Endophyte Acremonium zeae

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The maize endophyte Acremonium zeae was examined for production of extracellular enzymes that hydrolyze cellulose and hemicellulose. The most prominent enzyme activity in cell-free culture media from A. zeae NRRL 6415 was xylanase, with a specific activity of 60 U/mg from cultures grown on crude co...

  8. Viral load in 1-day-old and 6-week-old chickens infected with chicken anaemia virus by the intraocular route.

    PubMed

    Kaffashi, Amir; Noormohammadi, Amir H; Allott, Melinda L; Browning, Glenn F

    2006-12-01

    Although the effects of chicken anaemia virus (CAV) infection have frequently been investigated in young chickens, there have been few studies of the pathogenesis of CAV infection in older birds. The aim of the work reported here was to study viral loads in 6-week-old chickens and to compare these with those seen in younger birds. Specific pathogen free chickens were inoculated at 1 day or at 6 weeks of age with 10(4) median tissue culture infective doses of CAV by the intraocular route. Chicks infected when 1 day old were euthanized at day 14, 18 or 22 post inoculation (p.i.), and those infected when 6 weeks old at day 16, 18 or 20 p.i. Their body and thymus weights were determined and samples were collected from their spleen, liver and thymus. A quantitative polymerase chain reaction assay was developed and used to determine the number of viral genome copies in the tissue samples. In both age groups, viral genome concentrations increased in all organs up to day 18 p.i. and reached a peak in the spleen and liver at day 18 p.i. The peak viral concentrations in the thymus were detected at day 18 in the younger birds and at day 20 p.i. in older chickens. These studies have shown that exposure to CAV in older birds leads to similar levels of active viral replication to those seen in younger birds, and may result in subclinical infections in older birds with the potential to increase susceptibility to other infectious agents. PMID:17121736

  9. The complete mitochondrial genome of the nematophagous fungus Acremonium implicatum.

    PubMed

    Yao, Yurong; Lin, Runmao; Tian, Xueliang; Shen, Baoming; Mao, Zhenchuan; Xie, Bingyan

    2016-09-01

    The complete mitochondrial genome of the nematophagous fungus Acremonium implicatum is reported for the first time. The genome is concatenated with 22,367 bp in length, encoding 13 protein-coding genes, 2 ribosomal RNA genes and a set of 17 transfer RNA genes. The synteny analysis reveals that 50.35% of A. implicatum mitochondrial sequences matched to 48.21% of Acremonium chrysogenum mitochondrial sequences with 85.68% identity. Two proteins of cox3 and nad6, as well as seven tRNAs are lost in A. implicatum mitogenome compared to A. chrysogenum mitogenome. The gene orders in A. implicatum and A. chrysogenum mitogenome is different, which is mainly due to the location of nad4 and cox2. In addition, one transposition event related to tRNAs is identified in these two mitogenomes. This study may provide valuable mitochondrial information for research on A. implicatum and facilitate the study of mitochondrial evolution. PMID:25630733

  10. Interference by methionine on valine uptake in Acremonium chrysogenum.

    PubMed Central

    Alonso, M J; Luengo, J M

    1987-01-01

    The incorporation of L-[U-14C]valine into delta-(L-alpha-aminoadipyl)-L-cysteinyl-D-valine (ACV), a direct biosynthetic precursor of penicillins and cephalosporins, was studied. When DL-methionine was added to Acremonium chrysogenum culture broths, no labeled ACV was found, while a large amount of radioactive ACV was detected when methionine was not present. DL-Norleucine, a nonsulfur analog of methionine, also inhibited the synthesis of radioactive ACV to some degree. This effect was due to the inhibition of valine transport by methionine and norleucine. PMID:3566258

  11. Cellulases and hemicellulases from endophytic Acremonium species and its application on sugarcane bagasse hydrolysis.

    PubMed

    de Almeida, Maíra Nicolau; Guimarães, Valéria Monteze; Bischoff, Kenneth M; Falkoski, Daniel Luciano; Pereira, Olinto Liparini; Gonçalves, Dayelle S P O; de Rezende, Sebastião Tavares

    2011-09-01

    The aim of this work was to have cellulase activity and hemicellulase activity screenings of endophyte Acremonium species (Acremonium zeae EA0802 and Acremonium sp. EA0810). Both fungi were cultivated in submerged culture (SC) containing L -arabinose, D -xylose, oat spelt xylan, sugarcane bagasse, or corn straw as carbon source. In solid-state fermentation, it was tested as carbon source sugarcane bagasse or corn straw. The highest FPase, endoglucanase, and xylanase activities were produced by Acremonium sp. EA0810 cultivated in SC containing sugarcane bagasse as a carbon source. The highest β-glucosidase activity was produced by Acremonium sp. EA0810 cultivated in SC using D -xylose as carbon source. A. zeae EA0802 has highest α-arabinofuranosidase and α-galactosidase activities in SC using xylan as a carbon source. FPase, endoglucanase, β-glucosidase, and xylanase from Acremonium sp. EA0810 has optimum pH and temperatures of 6.0, 55 °C; 5.0, 70 °C; 4.5, 60 °C; and 6.5, 50 °C, respectively. α-Arabinofuranosidase and α-galactosidase from A. zeae EA0802 has optimum pH and temperatures of 5.0, 60 °C and 4.5, 45 °C, respectively. It was analyzed the application of Acremonium sp. EA0810 to hydrolyze sugarcane bagasse, and it was achieved 63% of conversion into reducing sugar and 42% of conversion into glucose. PMID:21573756

  12. Effects of the fungal endophyte Acremonium coenophialum on nitrogen accumulation and metabolism in tall fescue

    SciTech Connect

    Lyons, P.C. ); Evans, J.J.; Bacon, C.W. )

    1990-03-01

    Infection by the fungal endophyte Acremonium coenophialum affected the accumulation of inorganic and organic N in leaf blades and leaf sheaths of KY31 tall fescue (Festuca arundinacea Schreb.) grown under greenhouse conditions. Total soluble amino acid concentrations were increased in either the blade or sheath of the leaf from infected plants. A number of amino acids were significantly increased in the sheath, but only asparagine increased in the blade. Infection resulted in higher sheath NH{sub 4}{sup +} concentrations, whereas NO{sub 3}{sup {minus}} concentrations decreased in both leaf parts. The effects on amino acid, NO{sub 3}{sup {minus}}, and NH{sub 4}{sup +} concentrations were dependent upon the level of N fertilization and were usually apparent only at the high rate (10 millimolar) of application. Administration of {sup 14}CO{sub 2} to the leaf blades increased the accumulation of {sup 14}C in their amino acid fraction but not in the sheaths of infected plants. This may indicate that infection increased amino acid synthesis in the blade but that translocation to the sheath, which is the site of fungal colonization, was not affected. Glutamine synthetase activity was greater in leaf blades of infected plants at high and low N rates of fertilization, but nitrate reductase activity was not affected in either part of the leaf. Increased activities of glutamine synthetase together with the other observed changes in N accumulation and metabolism in endophyte-infected tall fescue suggest that NH{sub 4}{sup +} reassimilation could also be affected in the leaf blade.

  13. Interrelationships between Acremonium lolii, Peramine, and Lolitrem B in Perennial Ryegrass

    PubMed Central

    Ball, O. J.; Prestidge, R. A.; Sprosen, J. M.

    1995-01-01

    Perennial ryegrass (Lolium perenne L.) is commonly infected with the endophytic fungus Acremonium lolii in a mutualistic relationship. The fungus produces a number of alkaloids, some of which are responsible for causing livestock disorders and/or for conferring insect resistance to the host grass. Little is known about the interrelationship between fungal growth and alkaloid production in the ryegrass plant and how this varies throughout the year. The concentrations of A. lolii and two of its alkaloid metabolites, lolitrem B and peramine, were monitored in basal (mainly leaf sheath) and upper (mainly leaf blade) parts of 17 endophyte-infected ryegrass plants on a monthly basis for 1 year. A. lolii, lolitrem B, and peramine concentrations were lowest in winter. The highest A. lolii concentrations were recorded in early summer, which coincided with the development of plant reproductive structures. Lolitrem B concentrations were highest from summer to early autumn and were consistently highest in the basal part of the plant. Peramine concentrations were generally highest in the upper part of the plant. Individual plants contained different levels of A. lolii, lolitrem B and peramine. These differences were generally maintained throughout the year. Although data for each month were variable, regression analyses showed that yearly mean concentrations of lolitrem B and peramine in individual plants were closely related to, and therefore probably largely determined by, yearly mean concentrations of A. lolii. PMID:16535001

  14. Purification and Characterization of Two Arabinofuranosidases from the Maize Endophyte Acremonium zeae

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Acremonium zeae, one of the most prevalent fungal colonists of preharvest maize, produces a full complement of hemicellulolytic enzymes including xylanase, xylosidase, and arabinofuranosidase activities. In the present study, two arabinofuranosidases were purified to electrophoretic homogeneity fro...

  15. Purification and characterization of arabinofuranosidase from the corn endophyte Acremonium zeae

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Acremonium zeae, one of the most prevalent fungal colonists of preharvest corn, possesses a suite of hemicellulolytic activities including xylanase, xylosidase, and arabinofuranosidase. In the present study, two enzymes with arabinofuranosidase activity were purified from cell-free culture supernat...

  16. Lactose enhances cellulase production by the filamentous fungus Acremonium cellulolyticus.

    PubMed

    Fang, Xu; Yano, Shinichi; Inoue, Hiroyuki; Sawayama, Shigeki

    2008-08-01

    Acremonium cellulolyticus is a fungus that produces cellulase and has been exploited by enzyme industry. To promote cellulase production by A. cellulolyticus strain C-1, we evaluated the effects of the saccharides: Solka Floc (cellulose), soluble soybean polysaccharide (SSPS), pullulan, lactose, trehalose, sophorose, cellobiose, galactose, sorbose, lactobionic acid, and mixtures as carbon sources for cellulase production. Solka Floc with SSPS enhanced cellulase production. Lactose as the sole carbon source induced cellulase synthesis in this fungus, and the synergistic effects between lactose and Solka Floc was observed. Various enzyme activities and the protein composition of crude enzyme produced by cultures with or without addition of lactose were analyzed. The results showed that lactose addition greatly improves the production of various proteins with cellulase activity by A. cellulolyticus. To our knowledge, this is the first report on production of cellulases by lactose in the A. cellulolyticus. PMID:18804052

  17. Antimicrobial activity of pyrrocidines from Acremonium zeae against endophytes and pathogens of maize.

    PubMed

    Wicklow, Donald T; Poling, Stephen M

    2009-01-01

    Acremonium zeae produces pyrrocidines A and B, which are polyketide-amino acid-derived antibiotics, and is recognized as a seedborne protective endophyte of maize which augments host defenses against microbial pathogens causing seedling blights and stalk rots. Pyrrocidine A displayed significant in vitro activity against Aspergillus flavus and Fusarium verticillioides in assays performed using conidia as inoculum, with pyrrocidine A being more active than B. In equivalent assays performed with conidia or hyphal cells as inoculum, pyrrocidine A revealed potent activity against major stalk and ear rot pathogens of maize, including F. graminearum, Nigrospora oryzae, Stenocarpella (Diplodia) maydis, and Rhizoctonia zeae. Pyrrocidine A displayed significant activity against seed-rotting saprophytes A. flavus and Eupenicillium ochrosalmoneum, as well as seed-infecting colonists of the phylloplane Alternaria alternata, Cladosporium cladosporioides, and Curvularia lunata, which produces a damaging leaf spot disease. Protective endophytes, including mycoparasites which grow asymptomatically within healthy maize tissues, show little sensitivity to pyrrocidines. Pyrrocidine A also exhibited potent activity against Clavibacter michiganense subsp. nebraskense, causal agent of Goss's bacterial wilt of maize, and Bacillus mojaviense and Pseudomonas fluorescens, maize endophytes applied as biocontrol agents, but were ineffective against the wilt-producing bacterium Pantoea stewartii. PMID:19055442

  18. Relationships among non-Acremonium sp. fungal endophytes in five grass species.

    PubMed Central

    An, Z Q; Siegel, M R; Hollin, W; Tsai, H F; Schmidt, D; Schardl, C L

    1993-01-01

    Many cool-season grasses (subfamily Pooideae) possess maternally transmitted fungal symbionts which cause no known pathology and often enhance the ecological fitness and biochemical capabilities of the grass hosts. The most commonly described endophytes are the Acremonium section Albo-lanosa spp. (Acremonium endophytes), which are conidial anamorphs (strictly asexual forms) of Epichloë typhina. Other endophytes which have been noted are a Gliocladium-like fungus in perennial ryegrass (Lolium perenne L.) and a Phialophora-like fungus in tall fescue (Festuca arundinacea Schreb.). Here, we report the identification of additional non-Acremonium sp. endophytes (herein designated p-endophytes) in three more grass species: Festuca gigantea, Festuca arizonica, and Festuca pratensis. In each grass species, the p-endophyte was cosymbiotic with an Acremonium endophyte. Serological analysis and sequence determinations of variable portions of their rRNA genes indicated that the two previously identified non-Acremonium endophytes are closely related to each other and to the newly identified p-endophytes. Therefore, the p-endophytes represent a second group of widely distributed grass symbionts. Images PMID:8517749

  19. Extracellular hemicellulolytic enzymes from the maize endophyte Acremonium zeae.

    PubMed

    Bischoff, Kenneth M; Wicklow, Donald T; Jordan, Douglas B; de Rezende, Sebastiao T; Liu, Siqing; Hughes, Stephen R; Rich, Joseph O

    2009-05-01

    Microorganisms that colonize plants require a number of hydrolytic enzymes to help degrade the cell wall. The maize endophyte Acremonium zeae was surveyed for production of extracellular enzymes that hydrolyze cellulose and hemicellulose. The most prominent enzyme activity in cell-free culture medium from A. zeae NRRL 6415 was xylanase, with a specific activity of 60 U/mg from cultures grown on crude corn fiber. Zymogram analysis following SDS-PAGE indicated six functional xylanase polypeptides of the following masses: 51, 44, 34, 29, 23, and 20 kDa. Xylosidase (0.39 U/mg), arabinofuranosidase (1.2 U/mg), endoglucanase (2.3 U/mg), cellobiohydrolase (1.3 U/mg), and beta-glucosidase (0.85 U/mg) activities were also detected. Although apparently possessing a full complement of hemicellulolytic activities, cell-free culture supernatants prepared from A. zeae required an exogenously added xylosidase to release more than 90% of the xylose and 80% of the arabinose from corn cob and wheat arabinoxylans. The hydrolytic enzymes from A. zeae may be suitable for application in the bioconversion of lignocellulosic biomass into fermentable sugars. PMID:19184610

  20. Intraocular radiation blocking

    SciTech Connect

    Finger, P.T.; Ho, T.K.; Fastenberg, D.M.; Hyman, R.A.; Stroh, E.M.; Packer, S.; Perry, H.D. )

    1990-09-01

    Iodine-based liquid radiographic contrast agents were placed in normal and tumor-bearing (Greene strain) rabbit eyes to evaluate their ability to block iodine-125 radiation. This experiment required the procedures of tumor implantation, vitrectomy, air-fluid exchange, and 125I plaque and thermoluminescent dosimetry (TLD) chip implantation. The authors quantified the amount of radiation attenuation provided by intraocularly placed contrast agents with in vivo dosimetry. After intraocular insertion of a blocking agent or sham blocker (saline) insertion, episcleral 125I plaques were placed across the eye from episcleral TLD dosimeters. This showed that radiation attenuation occurred after blocker insertion compared with the saline controls. Then computed tomographic imaging techniques were used to describe the relatively rapid transit time of the aqueous-based iohexol compared with the slow transit time of the oil-like iophendylate. Lastly, seven nontumor-bearing eyes were primarily examined for blocking agent-related ocular toxicity. Although it was noted that iophendylate induced intraocular inflammation and retinal degeneration, all iohexol-treated eyes were similar to the control eyes at 7 and 31 days of follow-up. Although our study suggests that intraocular radiopaque materials can be used to shield normal ocular structures during 125I plaque irradiation, a mechanism to keep these materials from exiting the eye must be devised before clinical application.

  1. Effect of simulated acid rain on the mutualism between tall fescue (Festuca arundinacea) and an endophytic fungus (Acremonium coenophialum)

    SciTech Connect

    Cheplick, G.P. )

    1993-03-01

    Biotic interactions between plants and microorganisms have the potential to be affected by acidic precipitation. I examined the effect of simulated sulfuric acid rain on the mutualism between a perennial forage grass (Festuca arundinacea) and a fungal endophyte (Acremonium coenophialum). Acid water was supplied as mists sprayed onto leaf surfaces or as water added to the soil for two groups in a greenhouse: one group had high levels of endophyte infection, while the other was predominantly noninfected. Control plants received distilled water (pH 6), while others received sulfuric acid water at pH 4.5 or pH 3. Plants were harvested after 4, 6, 8, and 23 wk. Leaf endophyte infection intensity as measured by hyphal counts was not affected by acid water treatment. Root mass and root: shoot ratios generally decreased with increasing acidity of both foliar sprays and soil water, but shoot mass was mostly not affected. There was a significant pH x infection interaction for plants exposed to acidic foliar sprays for 4 wk; root and shoot mass decreased with acidity, but only for infected plants. It was found that acid rain may be deleterious to tall fescue growth at specific stages of development, but biomass production in response to acid rain is not likely to be influenced by fungal endophytes within mature plants. 55 refs., 2 figs., 3 tabs.

  2. Is the root-colonizing endophyte Acremonium strictum an ericoid mycorrhizal fungus?

    PubMed

    Grunewaldt-Stöcker, Gisela; von Alten, Henning

    2016-07-01

    In previous investigations, we found that Acremonium strictum (strain DSM 100709) developed intracellular structures with similarity to mycelia of ericoid mycorrhizal fungi in the rhizodermal cells of flax plants and in hair roots of Rhododendron plantlets. A. strictum had also been isolated from roots of ericaceous salal plants and was described as an unusual ericoid mycorrhizal fungus (ERMF). As its mycorrhizal traits were doubted, we revised the hypothesis of a mycorrhizal nature of A. strictum. A successful synthesis of mycorrhiza in hair roots of inoculated ericaceous plants was a first step of evidence, followed by fluorescence microscopy with FUN(®)1 cell stain to observe the vitality of the host cells at the early infection stage. In inoculation trials with in vitro-raised mycorrhiza-free Rhododendron plants in axenic liquid culture and in greenhouse substrate culture, A. strictum was never observed in living hair root cells. As compared to the ERMF Oidiodendron maius and Rhizoscyphus ericae that invaded metabolically active host cells and established a symbiotic unit, A. strictum was only found in cells that were dead or in the process of dying and in the apoplast. In conclusion, A. strictum does not behave like a common ERMF-if it is one at all. A comparison of A. strictum isolates from ericaceous and non-ericaceous hosts could reveal further identity details to generalize or specify our findings on the symbiotic nature of A. strictum. At least, the staining method enables to discern between true mycorrhizal and other root endophytes-a tool for further studies. PMID:26846148

  3. OCCURRENCE OF PYRROCIDINE PRODUCTION AMONG ACREMONIUM ZEAE POPULATIONS FROM MAIZE GROWN IN DIFFERENT REGIONS

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Acremonium zeae is recognized as a protective endophyte of maize and a potential confounding variable in maize variety trials for resistance to pathogenic microbes and their mycotoxins. This fungus grows systemically in maize and produces pyrrocidines A and B, polyketide-amino acid-derived antibiot...

  4. Isolation of an Isocoumarin and an Isobenzofuran Derivatives from a Fungicolous Isolate of Acremonium crotocinigenum

    Technology Transfer Automated Retrieval System (TEKTRAN)

    6,8-dimethoxy-4,5-dimethyl-3-methyleneisochroman-1-one (1) and 5,7-dimethoxy-3,4-dimethyl-3-hydroxy-isobenzofuranone (2), have been isolated from an organic extract of the fungicolous fungus Acremonium crotocinigenum (NRRL 40192). The structures of these compounds were elucidated on the basis of NM...

  5. Antimicrobial Activity of Pyrrocidines from Acremonium zeae against Endophytes and Pathogens of Maize

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Acremonium zeae produces pyrrocidines A and B, polyketide-amino acid-derived antibiotics, and is recognized as a seed-borne protective endophyte of maize which augments host defenses against microbial pathogens causing seedling blights and stalk rots. Pyrrocidine A displayed significant in vitro ac...

  6. Intraocular lens fabrication

    DOEpatents

    Salazar, M.A.; Foreman, L.R.

    1997-07-08

    This invention describes a method for fabricating an intraocular lens made from clear Teflon{trademark}, Mylar{trademark}, or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube. 13 figs.

  7. Intraocular lens fabrication

    DOEpatents

    Salazar, Mike A.; Foreman, Larry R.

    1997-01-01

    This invention describes a method for fabricating an intraocular lens made rom clear Teflon.TM., Mylar.TM., or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube.

  8. Laser therapy in intraocular tumors

    NASA Astrophysics Data System (ADS)

    Carstocea, Benone D.; Gafencu, Otilia L.; Apostol, Silvia

    1995-01-01

    Intraocular tumors present special problems of diagnosis and treatment. Diagnostic methods include, in addition to systemic and ophthalmological examinations, ancillary examinations such as transillumination, fluorescein angiography, ultrasonography, radioactive phosphorus uptake test, radiology, computerized tomography, and fine-needle aspiration biopsy with cytological analyses. Previously, enucleation of the involved eye was generally accepted as management of malignant tumors. Improved therapeutic methods such as photocoagulation and better surgical techniques now provide a variety of therapeutical alternatives. This study consists of 21 cases of intraocular tumors that were managed by Argon laser photocoagulation. Four cases were intraocular metastasis and 17 cases were primitive intraocular tumors. Argon laser therapy proved to be totally ineffective for the intraocular metastasis and a very adequate therapy for the primitive tumors. Tumor extirpations (choroidal, cillary body, or iris tumors) using laser lancet proved to be more suitable than classic surgery.

  9. Intraocular pressure reduction and regulation system

    NASA Technical Reports Server (NTRS)

    Baehr, E. F.; Burnett, J. E.; Felder, S. F.; Mcgannon, W. J.

    1979-01-01

    An intraocular pressure reduction and regulation system is described and data are presented covering performance in: (1) reducing intraocular pressure to a preselected value, (2) maintaining a set minimum intraocular pressure, and (3) reducing the dynamic increases in intraocular pressure resulting from external loads applied to the eye.

  10. [Phakic intraocular lenses].

    PubMed

    Kohnen, T; Shajari, M

    2016-06-01

    Refractive surgical procedures are generally divided into additive procedures with, e. g. implantation of an artificial lens and subtractive procedures with ablation of corneal tissue. In this article the current status of phakic intraocular lens (IOL) implantation for correction of refractive errors is reviewed. Phakic IOLs are constructed as angle-supported or iris-fixated anterior chamber lenses and sulcus-fixated posterior chamber lenses. The implantation of phakic IOLs has been demonstrated to be an effective, safe, predictable and stable procedure to correct higher refractive errors. Complications are rare and depend to a large extent on the location. For anterior chamber lenses the main concern is critical endothelial cell loss and for posterior chamber lenses early cataract formation. PMID:27277751

  11. Intraocular pressure reduction and regulation

    NASA Technical Reports Server (NTRS)

    Baehr, E. F.; Mcgannon, W. J.

    1979-01-01

    System designed to reduce intraocular pressure hydraulically to any level desired by physician over set time and in controlled manner has number of uses in ophthalmology. Device may be most immediately useful in treatment of glaucoma.

  12. Intraocular Gnathostomiasis: Report of a Case and Review of Literature

    PubMed Central

    Pillai, Gopal S.; Kumar, Anil; Radhakrishnan, Natasha; Maniyelil, Jayasree; Shafi, Tufela; Dinesh, Kavitha R.; Karim, Shamsul

    2012-01-01

    Intraocular gnathostomiasis is a rare parasitic infection caused by the third-stage larvae of spiruroid nematode Gnanthostoma spp. seen mostly in tropical and subtropical regions. It is a food-borne zoonosis caused by ingestion of raw or undercooked freshwater fish, amphibians, reptiles, birds, and mammals, all of which are known to harbor advanced third-stage larvae of Gnanthostoma spp. To date, 74 cases of intraocular gnathostomiasis have been reported from 12 different countries. Only four countries have reported more than 10 cases each, and India shares the rare distinction of being one of them, with 14 cases. Surprisingly, not a single case of cutaneous gnanthostomiasis has ever been reported from India. We present one such case of intraocular gnathostomiasis in a 41-year-old male who presented with an actively motile worm attached to the iris, and we review the pertinent literature of all such cases reported from India. PMID:22492146

  13. General Information about Intraocular (Uveal) Melanoma

    MedlinePlus

    ... Intraocular (Uveal) Melanoma Treatment (PDQ®)–Patient Version General Information About Intraocular (Uveal) Melanoma Go to Health Professional ... the PDQ Adult Treatment Editorial Board . Clinical Trial Information A clinical trial is a study to answer ...

  14. 21 CFR 886.4270 - Intraocular gas.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Intraocular gas. 886.4270 Section 886.4270 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4270 Intraocular gas. (a) Identification. An intraocular gas is a device consisting of a gaseous fluid intended to be introduced into the eye to place...

  15. 21 CFR 886.4270 - Intraocular gas.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraocular gas. 886.4270 Section 886.4270 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4270 Intraocular gas. (a) Identification. An intraocular gas is a device consisting of a gaseous fluid intended to be introduced into the eye to place...

  16. 21 CFR 886.3600 - Intraocular lens.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Intraocular lens. 886.3600 Section 886.3600 Food... DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials such as glass or plastic intended to be implanted to...

  17. 21 CFR 886.3600 - Intraocular lens.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Intraocular lens. 886.3600 Section 886.3600 Food... DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials such as glass or plastic intended to be implanted to...

  18. 21 CFR 886.3600 - Intraocular lens.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Intraocular lens. 886.3600 Section 886.3600 Food... DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials such as glass or plastic intended to be implanted to...

  19. 21 CFR 886.3600 - Intraocular lens.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Intraocular lens. 886.3600 Section 886.3600 Food... DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials such as glass or plastic intended to be implanted to...

  20. 21 CFR 886.3600 - Intraocular lens.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraocular lens. 886.3600 Section 886.3600 Food... DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials such as glass or plastic intended to be implanted to...

  1. 21 CFR 886.4270 - Intraocular gas.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Intraocular gas. 886.4270 Section 886.4270 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4270 Intraocular gas. (a) Identification. An intraocular gas is a device consisting of a gaseous fluid intended to be introduced into the eye to place...

  2. 21 CFR 886.4270 - Intraocular gas.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Intraocular gas. 886.4270 Section 886.4270 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4270 Intraocular gas. (a) Identification. An intraocular gas is a device consisting of a gaseous fluid intended to be introduced into the eye to place...

  3. 21 CFR 886.4270 - Intraocular gas.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Intraocular gas. 886.4270 Section 886.4270 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4270 Intraocular gas. (a) Identification. An intraocular gas is a device consisting of a gaseous fluid intended to be introduced into the eye to place...

  4. 21 CFR 886.4275 - Intraocular fluid.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraocular fluid. 886.4275 Section 886.4275 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4275 Intraocular fluid. (a) Identification. An intraocular fluid is a device consisting of a nongaseous fluid intended to be introduced into the eye to...

  5. 21 CFR 886.4275 - Intraocular fluid.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Intraocular fluid. 886.4275 Section 886.4275 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4275 Intraocular fluid. (a) Identification. An intraocular fluid is a device consisting of a nongaseous fluid intended to be introduced into the eye to...

  6. 21 CFR 886.4275 - Intraocular fluid.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Intraocular fluid. 886.4275 Section 886.4275 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4275 Intraocular fluid. (a) Identification. An intraocular fluid is a device consisting of a nongaseous fluid intended to be introduced into the eye to...

  7. 21 CFR 886.4275 - Intraocular fluid.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Intraocular fluid. 886.4275 Section 886.4275 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4275 Intraocular fluid. (a) Identification. An intraocular fluid is a device consisting of a nongaseous fluid intended to be introduced into the eye to...

  8. 21 CFR 886.4275 - Intraocular fluid.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Intraocular fluid. 886.4275 Section 886.4275 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4275 Intraocular fluid. (a) Identification. An intraocular fluid is a device consisting of a nongaseous fluid intended to be introduced into the eye to...

  9. The production and characterization of a new active lipase from Acremonium alcalophilum using a plant bioreactor

    PubMed Central

    2013-01-01

    Background Microorganisms are the most proficient decomposers in nature, using secreted enzymes in the hydrolysis of lignocellulose. As such, they present the most abundant source for discovery of new enzymes. Acremonium alcalophilum is the only known cellulolytic fungus that thrives in alkaline conditions and can be cultured readily in the laboratory. Its optimal conditions for growth are 30°C and pH 9.0-9.2. The genome sequence of Acremonium alcalophilum has revealed a large number of genes encoding biomass-degrading enzymes. Among these enzymes, lipases are interesting because of several industrial applications including biofuels, detergent, food processing and textile industries. Results We identified a lipA gene in the genome sequence of Acremonium alcalophilum, encoding a protein with a predicted lipase domain with weak sequence identity to characterized enzymes. Unusually, the predicted lipase displays ≈ 30% amino acid sequence identity to both feruloyl esterase and lipase of Aspergillus niger. LipA, when transiently produced in Nicotiana benthamiana, accumulated to over 9% of total soluble protein. Plant-produced recombinant LipA is active towards p-nitrophenol esters of various carbon chain lengths with peak activity on medium-chain fatty acid (C8). The enzyme is also highly active on xylose tetra-acetate and oat spelt xylan. These results suggests that LipA is a novel lipolytic enzyme that possesses both lipase and acetylxylan esterase activity. We determined that LipA is a glycoprotein with pH and temperature optima at 8.0 and 40°C, respectively. Conclusion Besides being the first heterologous expression and characterization of a gene coding for a lipase from A. alcalophilum, this report shows that LipA is very versatile exhibiting both acetylxylan esterase and lipase activities potentially useful for diverse industry sectors, and that tobacco is a suitable bioreactor for producing fungal proteins. PMID:23915965

  10. Bisacremines E-G, Three Polycyclic Dimeric Acremines Produced by Acremonium persicinum SC0105.

    PubMed

    Wu, Ping; Xue, Jinghua; Yao, Lei; Xu, Liangxiong; Li, Hanxiang; Wei, Xiaoyi

    2015-10-01

    Three dimeric acremines, bisacremines E-G (1-3), with an unusual carbon skeleton were isolated from cultures of the soil-derived fungus Acremonium persicinum SC0105. Their structures were elucidated by spectroscopic analysis, X-ray diffraction, and ECD/TDDFT computations. Compound 3 exhibited inhibitory effects on the production of TNF-α, IL-6, and NO in LPS-stimulated macrophages. A biogenetic pathway with a [4 + 2] cycloaddition as the key reaction is proposed for 1-3. PMID:26399982

  11. A glucuronoyl esterase from Acremonium alcalophilum cleaves native lignin-carbohydrate ester bonds.

    PubMed

    Arnling Bååth, Jenny; Giummarella, Nicola; Klaubauf, Sylvia; Lawoko, Martin; Olsson, Lisbeth

    2016-08-01

    The Glucuronoyl esterases (GE) have been proposed to target lignin-carbohydrate (LC) ester bonds between lignin moieties and glucuronic acid side groups of xylan, but to date, no direct observations of enzymatic cleavage on native LC ester bonds have been demonstrated. In the present investigation, LCC fractions from spruce and birch were treated with a recombinantly produced GE originating from Acremonium alcalophilum (AaGE1). A combination of size exclusion chromatography and (31) P NMR analyses of phosphitylated LCC samples, before and after AaGE1 treatment provided the first evidence for cleavage of the LC ester linkages existing in wood. PMID:27397104

  12. Exogenous endophthalmitis caused by Enterococcus casseliflavus: A case report and discussion regarding treatment of intraocular infection with vancomycin-resistant enterococci

    PubMed Central

    Berenger, Byron M; Kulkarni, Shobhana; Hinz, Brad J; MD, Sarah E Forgie

    2015-01-01

    BACKGROUND: Endophthalmitis caused by enterococci is rare, and cases involving vancomycin-resistant enterococci are even more so. Due to the poor bioavailability of many antibiotics in the vitreous chamber, special considerations are required when choosing antibiotics to treat these infections. The authors report the first case of exogenous endophthalmitis caused by Enterococcus casseliflavus via the unique mechanism of high-velocity water stream trauma from a toy water gun. A previously healthy four-year old boy presented with endophthalmitis of the left eye after injury from a water gun. Empirical treatment for endophthalmitis was started on presentation to the ophthalmologist. After the identification of the pathogen and a review of the literature, the antibiotic regimen was changed to include intravitreal ampicillin and amikacin with systemic linezolid. Endophthalmitis caused by E casseliflavus and other vancomycin-resistant enterococci are challenging to treat. Rapid identification of vancomycin-resistant enterococcal endophthalmitis is important to guide appropriate antibiotic therapy. Systemic linezolid achieves excellent intravitreal concentrations, and should be used in combination with intravitreal and topical antibiotics. PMID:26744592

  13. The Fyodorov Sputnik intraocular lens.

    PubMed

    Kwitko, M L

    1979-04-01

    The author has implanted 197 Fyodorov intraocular lenses. With careful selection of patients, good surgical judgment, and meticulous surgery, a degree of success can be obtained with this lens, which will equal that of conventional cataract surgery. The surgical technique of implantation will be described. PMID:537770

  14. A Battle in a Kernel: Molecular Exploration of Antagonisms between Two Maize Endophytes, Fusarium verticillioides and Acremonium zeae

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Fusarium verticillioides (Fv) is a prevalent seed-borne maize endophyte capable of causing severe kernel rot and fumonisin mycotoxin contamination. Within maize kernels, Fv is primarily confined to the pedicel, while another seed-borne fungal endophyte, Acremonium zeae (Az), is observed in embryos. ...

  15. [Special intra-ocular lenses].

    PubMed

    Jacobi, K W; Nowak, M R; Strobel, J

    1990-01-01

    Intraocular lens (IOL) implantation is the method established worldwide for visual rehabilitation following cataract surgery. IOL's with particular characteristics and/or for special purposes are available for clinical or experimental use. Bifocal and multifocal IOLs have two or more foci for simultaneous far and near vision. The first clinical results are promising. The theoretically expected disadvantages, i.e., reduced contrast sensitivity or reduced visual acuity under reduced contrast conditions, have not yet been found in clinical studies. In cases of age-related macular degeneration, IOLs with a high negative diopter power in the center can be implanted as part of a Galilei telescope. By using high-plus power spectacles, a 2.5x to 4x magnification and a wide field of view can be achieved. Clinical investigation has started recently. Intraocular lenses for the correction of high-grade myopia are being tested by some surgeons. These lenses are made to be implanted in phakic eyes with a clear crystalline lens. Angle-supported and iris-fixated types are under investigation. Longterm results will show the clinical efficacy and safety. Other special intraocular lenses are iris-color lenses and a polymethymethacrylate (PMMA) iris diaphragm. PMID:2083909

  16. Acremonium zeae, a protective endophyte of maize, produces dihydroresorcylide and 7-hydroxydihydroresorcylides.

    PubMed

    Poling, Stephen M; Wicklow, Donald T; Rogers, Kristina D; Gloer, James B

    2008-05-14

    Acremonium zeae has been characterized as a protective endophyte of maize and displays antifungal activity against other fungi. Pyrrocidines A and B were discovered to be the metabolites accounting for this activity. During a population survey of A. zeae isolates from maize seeds produced in nine states to determine their ability to produce pyrrocidines, another metabolite of A. zeae, unrelated to the pyrrocidines, was found to have widespread occurrence (105 of 154 isolates) and to be produced in amounts comparable to the pyrrocidines. Further chemical studies of fermentation extracts of an A. zeae isolate (NRRL 45893) from maize led to the identification of a new compound, dihydroresorcylide, the saturated analogue of cis-resorcylide. Also identified were the two diastereomers of 7-hydroxydihydroresorcylide. Dihydroresorcylide and pyrrocidines A and B were detected by LC-APCI-MS in symptomatic maize kernels from ears that were wound-inoculated in the milk stage with A. zeae NRRL 34559. PMID:18416554

  17. Pupillary block glaucoma following intraocular lens implantation.

    PubMed

    Kielar, R A; Stambaugh, J L

    1982-08-01

    Seven cases of pupillary block granuloma occurred in a series of 665 consecutive cases of cataract extraction with insertion of an iris supported intraocular lens, an overall incidence of 1%. The incidence with an iris plane lens was 1.7%, and for all other styles used the incidence was 0.3%. Common factors noted were iris plane intraocular lens and early postoperative complications predisposing to pupillary block. In four of the seven cases, there was a period of normal intraocular pressure followed by elevated intraocular tension with a deep central anterior chamber two weeks to fifteen months following cataract extraction, with subsequent development of corneal edema and typical shallowing of the anterior chamber with iris bombe. Five of seven cases ultimately regained control of intraocular pressure although extensive peripheral anterior synechia were present. No patient ultimately had a visual acuity better than 20/50. PMID:7133608

  18. Transillumination imaging of intraocular tumours.

    PubMed

    Kjersem, Bård; Krohn, Jørgen

    2013-06-01

    The purpose of this paper is to discuss a recently described modification of a standard photo slit lamp system for ocular transillumination, with special emphasis on the light transmission through the eye wall and the photographic technique. Transillumination photography was carried out with the Haag-Streit Photo-Slit Lamp BX 900 (Haag-Streit AG, Koeniz, Switzerland). After having released the background lighting optic fibre cable from its holder, the patient was positioned at the slit lamp, and the fibre tip was gently pressed against the sclera or the cornea of the patient's eye. During about 1/1000 of a second, the eye was illuminated by the flash and the scleral shadow of the tumour was exposed to the camera sensor. The images were of good diagnostic quality, making it easy to outline the tumours and to evaluate the involvement of intraocular structures. None of the examined patients experienced discomfort or negative side effects. The method is recommended in cases where photographic transillumination documentation of intraocular pathologies is considered important. PMID:23641762

  19. IRIS: Integrated Robotic Intraocular Snake*

    PubMed Central

    He, Xingchi; van Geirt, Vincent; Gehlbach, Peter; Taylor, Russell; Iordachita, Iulian

    2015-01-01

    Retinal surgery is one of the most technically challenging surgical disciplines. Many robotic systems have been developed to enhance the surgical capabilities. However, very few of them provide the surgeon the dexterity within the patient’s eye to enable more flexible, more advanced surgical procedures. This paper presents a sub-millimeter intraocular dexterous robot, the Integrated Robotic Intraocular Snake (IRIS). The variable neutral-line mechanism is used to provide very high dexterity with a very small form factor. The IRIS distal dexterous unit is 0.9 mm in diameter and about 3 mm in length. It enables two rotational degrees of freedom at the distal end of the ophthalmic instruments. The analysis on contact mechanics provides a reference for the adjustment of the wire pretension. Redundant actuation is implemented by using one motor for each wire. A motion scaling transmission is developed to overcome the suboptimal resolution of the motors. A scale-up model of the IRIS is built for initial experimental evaluation. Preliminary results show that the scale-up IRIS can provide large range of motion. For given bending angle, the kinematic model can estimate the desired wire translation when the friction is not significant. The first prototype of the actual-scale IRIS is assembled and tested. PMID:26405561

  20. Cytomegalovirus retinitis mimicking intraocular lymphoma.

    PubMed

    Gooi, Patrick; Farmer, James; Hurley, Bernard; Brodbaker, Elliott

    2008-12-01

    We present a case of an unusual retinal infiltrate requiring retinal biopsy for definitive diagnosis. A 62-year-old man with treated lymphoma presented with decreased vision in the right eye associated with a white retinal lesion, which extended inferonasally from an edematous disc. Intraocular lymphoma was considered as a diagnosis; thus, the patient was managed with vitrectomy and retinal biopsy. Cytological analysis of the vitreous aspirate could not rule out a lymphoproliferative disorder. The microbial analysis was negative. Histology of the lesion showed extensive necrosis and large cells with prominent nucleoli. To rule out lymphoma, a battery of immunostains was performed and all were negative. However the limited amount of tissue was exhausted in the process. Subsequently, a hematoxylin and eosin (H/E) slide was destained, on which a CMV immunostain was performed. This revealed positivity in the nuclei and intranuclear inclusions within the large atypical cells. A diagnosis of CMV retinitis was made. Retinal biopsy may provide a definitive diagnosis and direct patient care toward intravenous gancyclovir in the case of CMV or toward radiation and chemotherapy for intraocular lymphoma. When faced with a limited amount of tissue, destaining regular H/E slides is a possible avenue to performing additional immunohistochemical studies. PMID:19668455

  1. Periocular migration of an intraocular lens.

    PubMed

    Jenkins, C

    1992-11-01

    A woman presented with a painful eye 6 weeks after cataract extraction and intraocular lens implantation. In the past she had had a sector iridectomy for iris bombé caused by chronic anterior uveitis. On examination the three central corneal sutures were absent, whilst the medial and lateral sutures had broken and were protruding from the section. The eye was quiet and the section intact. Combined clinical and ultrasound examination failed to locate the intraocular lens. Four months postoperatively, while being fitted for contact lenses for the correction of aphakia, the intraocular lens appeared from the superior fornix. PMID:1477048

  2. Pupillary block after intraocular lens implantation.

    PubMed

    Van Buskirk, E M

    1983-01-01

    Seventeen patients, ranging in age from 40 to 86 years, developed pupillary block detected one week to three years after intraocular lens implantation. Sixteen of the implants were anterior chamber intraocular lenses and one was a posterior chamber intraocular lens. Despite iris bombé that closed the anterior chamber angle, many cases were asymptomatic and were discovered fortuitously during routine postoperative examinations. Laser iridotomy or iridectomy eliminated the pupillary block in all 17 cases, but permanent synechial closure of a portion of the anterior chamber angle persisted in most cases and sometimes required medication or further surgery. One eye eventually lost all light perception. PMID:6849369

  3. Cataract surgery and intraocular pressure.

    PubMed

    Melancia, Diana; Abegão Pinto, Luis; Marques-Neves, Carlos

    2015-01-01

    Cataract surgery is one of the most performed surgeries in the developed world. In addition to its significant impact on visual acuity, phacoemulsification has been hailed as a potential intraocular pressure (IOP)-lowering procedure. While current evidence suggests an overall significant and sustained decrease in IOP to exist after cataract surgery, the specific ocular characteristics that could help predict which patients are likely to benefit from this IOP-lowering effect remain unclear. This definition is important in glaucoma patients if this surgery is to be used in the treatment for this disease. Our review aims to summarize the literature on the subject, depicting possible mechanisms behind this IOP decrease, which type of patients are more likely to benefit from this surgery for IOP-lowering purposes and ultimately help optimizing disease management for the increasing number of patients with concomitant glaucoma and cataract. PMID:25765255

  4. Cellulose-inducible xylanase Xyl10A from Acremonium cellulolyticus: Purification, cloning and homologous expression.

    PubMed

    Kishishita, Seiichiro; Yoshimi, Miho; Fujii, Tatsuya; Taylor, Larry E; Decker, Stephen R; Ishikawa, Kazuhiko; Inoue, Hiroyuki

    2014-02-01

    Cellulose-inducible endo-β-1,4-xylanase (Xyl10A) from the mesophilic fungus Acremonium cellulolyticus was purified, characterized, and expressed by a homologous expression system. A. cellulolyticus CF-2612 produces a high level of xylanase upon induction by Solka-Floc cellulose. To identify this xylanase, the major fraction showing xylanase activity was purified from the CF-2612 culture supernatant, and its gene was identified from the genome sequence. Amino acid sequence homology of Xyl10A revealed that the purified xylanase, designated Xyl10A, exhibited significant homology to family 10 of the glycoside hydrolases (GH10), possessing a cellulose-binding module 1 in the C-terminal region. The xyl10A gene was cloned and expressed in A. cellulolyticus under the control of a glucoamylase promoter. Two recombinant Xyl10As (rXyl10A-I, 53kDa, and rXyl10A-II, 51kDa) were purified that have slightly different molecular weights based on SDS-PAGE. The rXyl10As had the same physicochemical and enzymatic properties as wtXyl10A: high thermostability (Tm 80.5°C), optimum pH 5.0 and specific activity 232-251U/mg for birchwood xylan. The molecular weights of N-deglycosylated rXyl10As were consistent with that of wild-type Xyl10A (wtXyl10A, 51kDa). PMID:24211645

  5. Cyclosporin C is the main antifungal compound produced by Acremonium luzulae.

    PubMed Central

    Moussaïf, M; Jacques, P; Schaarwächter, P; Budzikiewicz, H; Thonart, P

    1997-01-01

    A strain of Acremonium luzulae (Fuckel) W. Gams was selected in screening new microorganisms for biological control of fruit postharvest diseases, especially gray and blue mold diseases on apples and strawberries. This strain manifests a very strong activity against a large number of phytopathogenic fungi. In this work, the product responsible for this antifungal activity was isolated from modified Sabouraud dextrose broth cultures of A. luzulae. It was purified to homogeneity by reverse-phase column chromatography. On the basis of UV, infrared, and 1H and 13C nuclear magnetic resonance spectra, mass spectral analysis, and the amino acid composition of the acid hydrolysates, the antibiotic was determined to be cyclosporin C. Cyclosporin C showed a broad-spectrum activity against filamentous phytopathogenic fungi but no activity against bacteria or yeasts. Its antifungal activity is only fungistatic. In contrast to Tolypocladium inflatum, another cyclosporin-producing strain, A. luzulae, did not produce additional cyclosporins. This was confirmed by in vivo-directed biosynthesis. PMID:9143111

  6. Crystal structure of Talaromyces cellulolyticus (formerly known as Acremonium cellulolyticus) GH family 11 xylanase.

    PubMed

    Kataoka, Misumi; Akita, Fusamichi; Maeno, Yuka; Inoue, Benchaporn; Inoue, Hiroyuki; Ishikawa, Kazuhiko

    2014-10-01

    Talaromyces cellulolyticus (formerly known as Acremonium cellulolyticus) is one of the mesophilic fungi that can produce high levels of cellulose-related enzymes and are expected to be used for the degradation of polysaccharide biomass. In silico analysis of the genome sequence of T. cellulolyticus detected seven open reading frames (ORFs) showing homology to xylanases from glycoside hydrolase (GH) family 11. The gene encoding the GH11 xylanase C (TcXylC) with the highest activity was used for overproduction and purification of the recombinant enzyme, permitting solving of the crystal structure to a resolution of 1.98 Å. In the asymmetric unit, two kinds of the crystal structures of the xylanase were identified. The main structure of the protein showed a β-jelly roll structure. We hypothesize that one of the two structures represents the open form and the other shows the close form. The changing of the flexible region between the two structures is presumed to induce and accelerate the enzyme reaction. The specificity of xylanase toward the branched xylan is discussed in the context of this structural data and by comparison with the other published structures of xylanases. PMID:25138599

  7. Purification and characterization of arabinofuranosidase from the corn endophyte Acremonium zeae.

    PubMed

    Bischoff, Kenneth M; de Rezende, Sebastiao T; Larson, Troy M; Liu, Siqing; Hughes, Stephen R; Rich, Joseph O

    2011-10-01

    Acremonium zeae, one of the most prevalent fungal colonists of preharvest corn, possesses a suite of hemicellulolytic activities including xylanase, xylosidase, and arabinofuranosidase. Two enzymes with arabinofuranosidase activity were purified from cell-free culture supernatants of A. zeae grown on oat spelt xylan. A 47 kDa enzyme (AF47) was optimally active at 37 °C and pH 6.0, and had a specific activity for 4-nitrophenyl-α-L-arabinofuranoside (4NPA) of 6.2 U/mg. A 30 kDa enzyme (AF30) was optimally active at 50 °C and pH 4.5, and had a specific activity for 4NPA of 12.4 U/mg. AF47 hydrolyzed 4-nitrophenyl-β-D-xylopyranoside, 4-nitrophenyl-β-D-glucopyranoside, and 4-nitrophenyl-β-D-cellobioside, as well as producing reducing sugars from corn fiber, wheat, and oat spelt arabinoxylan. AF30 had little detectable activity on the 4-nitrophenyl substrates, except for 4NPA, but activity on arabinoxylans from corn fiber, wheat, and oat spelt was at least 7-fold higher than AF47, with specific activities of 109, 358, and 153 U/mg, respectively. A combination of the two enzymes released 61 and 88% of the total arabinose from corn fiber and wheat arabinoxylans. The arabinofuranosidases produced by A. zeae may have industrial application for the enzymatic hydrolysis of recalcitrant lignocellulosic feedstocks such as corn fiber and wheat straw. PMID:21671092

  8. Manganese(IV) Oxide Production by Acremonium sp. Strain KR21-2 and Extracellular Mn(II) Oxidase Activity

    PubMed Central

    Miyata, Naoyuki; Tani, Yukinori; Maruo, Kanako; Tsuno, Hiroshi; Sakata, Masahiro; Iwahori, Keisuke

    2006-01-01

    Ascomycetes that can deposit Mn(III, IV) oxides are widespread in aquatic and soil environments, yet the mechanism(s) involved in Mn oxide deposition remains unclear. A Mn(II)-oxidizing ascomycete, Acremonium sp. strain KR21-2, produced a Mn oxide phase with filamentous nanostructures. X-ray absorption near-edge structure (XANES) spectroscopy showed that the Mn phase was primarily Mn(IV). We purified to homogeneity a laccase-like enzyme with Mn(II) oxidase activity from cultures of strain KR21-2. The purified enzyme oxidized Mn(II) to yield suspended Mn particles; XANES spectra indicated that Mn(II) had been converted to Mn(IV). The pH optimum for Mn(II) oxidation was 7.0, and the apparent half-saturation constant was 0.20 mM. The enzyme oxidized ABTS [2,2′-azinobis(3-ethylbenzothiazoline-6-sulfonic acid)] (pH optimum, 5.5; Km, 1.2 mM) and contained two copper atoms per molecule. Moreover, the N-terminal amino acid sequence (residues 3 to 25) was 61% identical with the corresponding sequence of an Acremonium polyphenol oxidase and 57% identical with that of a Myrothecium bilirubin oxidase. These results provide the first evidence that a fungal multicopper oxidase can convert Mn(II) to Mn(IV) oxide. The present study reinforces the notion of the contribution of multicopper oxidase to microbially mediated precipitation of Mn oxides and suggests that Acremonium sp. strain KR21-2 is a good model for understanding the oxidation of Mn in diverse ascomycetes. PMID:17021194

  9. Surface Modification of Intraocular Lenses

    PubMed Central

    Huang, Qi; Cheng, George Pak-Man; Chiu, Kin; Wang, Gui-Qin

    2016-01-01

    Objective: This paper aimed to review the current literature on the surface modification of intraocular lenses (IOLs). Data Sources: All articles about surface modification of IOLs published up to 2015 were identified through a literature search on both PubMed and ScienceDirect. Study Selection: The articles on the surface modification of IOLs were included, but those on design modification and surface coating were excluded. Results: Technology of surface modification included plasma, ion beam, layer-by-layer self-assembly, ultraviolet radiation, and ozone. The main molecules introduced into IOLs surface were poly (ethylene glycol), polyhedral oligomeric silsesquioxane, 2-methacryloyloxyethyl phosphorylcholine, TiO2, heparin, F-heparin, titanium, titanium nitride, vinyl pyrrolidone, and inhibitors of cytokines. The surface modification either resulted in a more hydrophobic lens, a more hydrophilic lens, or a lens with a hydrophilic anterior and hydrophobic posterior surface. Advances in research regarding surface modification of IOLs had led to a better biocompatibility in both in vitro and animal experiments. Conclusion: The surface modification is an efficient, convenient, economic and promising method to improve the biocompatibility of IOLs. PMID:26830993

  10. Multifocal intraocular lenses and glare.

    PubMed

    Akutsu, H; Legge, G E; Luebker, A; Lindstrom, R L; Zabel, R W; Kirby, V M

    1993-06-01

    In a previous paper, we reported finding deficits in the contrast sensitivity functions of patients with diffractive multifocal intraocular lenses (IOL's). The results were consistent with optical measurements of the modulation transfer function (MTF) of the IOL. When this MTF is treated as a linear spatial frequency filter, it predicts the existence of a glare effect; contrast threshold for the recognition of target letters should be elevated by a bright, adjacent stimulus. We tested this prediction by measuring contrast thresholds for recognizing 0.2 degrees Sloan letters on a background luminance of 11.2 cd/m2. The letters were presented inside bright (300 cd/m2) annular rings with inner diameters ranging from 0.42 to 1.22 degrees. Thresholds were measured for seven multifocal subjects, age-matched groups of monofocal subjects and phakic-control subjects, and a young group. Multifocal subjects exhibited a greater glare effect than monofocal subjects, and they in turn exhibited a greater effect than phakic-control subjects. The observed glare effect for multifocal subjects was about twice that expected from the spatial filtering property of the multifocal IOL. PMID:8336911

  11. [Intraocular pressure measurement in children].

    PubMed

    Bresson-Dumont, H

    2009-03-01

    Intraocular pressure (IOP) measurement in children is often difficult to perform because younger children are non-compliant and resisting the examination. Normal IOP in children is not well established yet because in the studies reporting about IOP, the instruments used and clinical conditions have varied. Non contact tonometer often overestimates IOP in blinking children and is not always reliable. But all the others measurement techniques use contact (GAT, Perkins, Tono-Pen, ORA, RBT), and are not always suitable and easy-touse. Under general anaesthesia, mean IOP measured with Perkins applanation tonometer is under 8 mmHg before age of 3 months and under 12 mmHg between ages of 6 and 9 months. After, IOP shows an increasing trend with age of 1 mmHg per year up to 12 years. Some studies have proposed as normal pediatric IOP: To=0.71 x age (years) +10, up to age 10. Then, IOP tends to approach adult levels by 12 years of age. However pediatric glaucoma is rare: congenital glaucoma, before age of 3 years, autosomal dominant juvenile glaucoma, with family history of glaucoma and elevated IOP, or secondary glaucoma with special context. Thus, hypertony has to be confirmed by another measurement technique, correlated to central corneal thickness, and clinical examination (optic nerve head and visual field). PMID:19515328

  12. Biopsy techniques for intraocular tumors.

    PubMed

    Rishi, Pukhraj; Dhami, Abhinav; Biswas, Jyotirmay

    2016-06-01

    Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB) to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88-95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous), suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies. PMID:27488148

  13. Biopsy techniques for intraocular tumors

    PubMed Central

    Rishi, Pukhraj; Dhami, Abhinav; Biswas, Jyotirmay

    2016-01-01

    Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB) to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88–95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous), suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies. PMID:27488148

  14. Gliotoxin-producing endophytic Acremonium sp. from Zingiber officinale found antagonistic to soft rot pathogen Pythium myriotylum.

    PubMed

    Anisha, C; Radhakrishnan, E K

    2015-04-01

    Soft rot caused by Pythium sp. is a major cause of economic loss in ginger cultivation. Endophytic fungi isolated from Zingiber officinale were screened for its activity against the soft rot pathogen Pythium myriotylum. Among the isolates screened, an endophytic fungus which was identified as Acremonium sp. showed promising activity against the phytopathogen in dual culture. The selected fungus was cultured in large scale on solid rice media and was extracted with ethyl acetate. The crude extract was subjected to column chromatography and preparative HPLC to obtain the fraction with the antifungal activity. LC-QTOF-MS/MS analysis of this fraction done using water-acetonitrile gradient identified a mass of m/z 327 (M + H) corresponding to gliotoxin with specific fragments m/z 263, 245, 227, and 111. The result was reconfirmed in negative mode ionization. Gliotoxin is the major antagonistic peptide produced by the commercially used biocontrol agent, Trichoderma sp., which shows high antagonism against Pythium sp. The gliotoxin production by the isolated endophytic Acremonium sp. of Z. officinale shows the possible natural biocontrol potential of this endophytic fungus. PMID:25820297

  15. Bioaugmentation of soil contaminated with high-level crude oil through inoculation with mixed cultures including Acremonium sp.

    PubMed

    Ma, Xiao-Kui; Ding, Ning; Peterson, Eric Charles

    2015-06-01

    Heavy contamination of soil with crude oil has caused significant negative environmental impacts and presents substantial hazards to human health. To explore a highly efficient bioaugmentation strategy for these contaminations, experiments were conducted over 180 days in soil heavily contaminated with crude oil (50,000 mg kg(-1)), with four treatments comprised of Bacillus subtilis inoculation with no further inoculation (I), or reinoculation after 100 days with either B. subtilis (II), Acremonium sp.(III), or a mixture of both organisms (IV). The removal values of total petroleum hydrocarbons were 60.1 ± 2.0, 60.05 ± 3.0, 71.3 ± 5.2 and 74.2 ± 2.7 % for treatment (I-IV), respectively. Treatments (III-IV) significantly enhanced the soil bioremediation compared with treatments (I-II) (p < 0.05). Furthermore, significantly (p < 0.05) greater rates of degradation for petroleum hydrocarbon fractions were observed in treatments (III-IV) compared to treatments (I-II), and this was especially the case with the degradative rates for polycyclic aromatic hydrocarbons and crude oil heavy fractions. Dehydrogenase activity in treatment (III-IV) containing Acremonium sp. showed a constant increase until the end of experiments. Therefore reinoculation with pure fungus or fungal-bacterial consortium should be considered as an effective strategy in bioaugmentation for soil heavily contaminated with crude oil. PMID:25929330

  16. Soluble inhibitors generated during hydrothermal pretreatment of oil palm mesocarp fiber suppressed the catalytic activity of Acremonium cellulase.

    PubMed

    Zakaria, Mohd Rafein; Hirata, Satoshi; Fujimoto, Shinji; Ibrahim, Izzudin; Hassan, Mohd Ali

    2016-01-01

    Oil palm mesocarp fiber was subjected to hydrothermal pretreatment under isothermal and non-isothermal conditions. The pretreated slurries were separated by filtration, pretreated liquids and solids were characterized. An enzymatic digestibility study was performed for both pretreated slurries and solids to understand the effect of soluble inhibitors generated during the pretreatment process. The highest glucose yield obtained from pretreated slurries was 70.1%, and gradually decreased with higher pretreatment severities. The highest glucose yield obtained in pretreated solids was 100%, after pretreatment at 210°C for 20min. In order to study the inhibitory effects of compounds generated during pretreatment with cellulase, technical grade solutions that mimic the pretreated liquid were prepared and their effect on Acremonium cellulase activity was monitored using Avicel. Xylo-oligomers and tannic acid were identified as powerful inhibitors of Acremonium cellulase, and the lowest hydrolysis rate of Avicel of 0.18g/g-glucose released/L/h was obtained from tannic acid. PMID:26524253

  17. Commercial air travel after intraocular gas injection.

    PubMed

    Houston, Stephen; Graf, Jürgen; Sharkey, James

    2012-08-01

    Passengers with intraocular gas are at risk of profound visual loss when exposed to reduced absolute pressure within the cabin of a typical commercial airliner. Information provided on the websites of the world's 10 largest airlines offer a considerable range of opinion as to when it might be safe to fly after gas injection. Physicians responsible for clearing pseassengers as 'fit to fly' should be aware modern retinal surgical techniques increasingly employ long-acting gases as vitreous substitutes. The kinetics of long-acting intraocular gases must be considered when deciding how long after surgery it is safe to travel. It is standard practice to advise passengers not to fly in aircraft until the gas is fully resorbed. To achieve this, it may be necessary to delay travel for approximately 2 wk after intraocular injection of sulfur hexafluoride (SF6) and for 6 wk after injection of perfluoropropane (C3F8). PMID:22872998

  18. [A morbidity study of intraocular foreign bodies].

    PubMed

    Mocanu, C; Bădescu, S

    1993-01-01

    190 patients presenting intraocular foreign bodies, hospitalized between 1981-1991, are examined. The study of accidents: cases showed a clear prevalence of work accidents--127 cases (66.84%); 86 of these cases occurred in industry (45.26%), the rest of 41 occurred in agriculture (21.58%). The professions most exposed to such accidents are those of locksmith, mechanic in agriculture or automobile industry. The postsurgical evolution and the incidence of complications show that intraocular foreign bodies are wosse-making factors of ocular plagues, because of anatomical structures disorganization, transparency modifications and infectious complications implied, which determined the diminishing of visual acuity in 88.08% of cases. The big percentage of work accidents in the etiology of intraocular foreign bodies emphasize the great importance of foreign the work-protection rules (regarding a especially the wearing of protection glasses) and of introducing of automation in technological processes involving great risks. PMID:8507606

  19. 21 CFR 886.4280 - Intraocular pressure measuring device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraocular pressure measuring device. 886.4280... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4280 Intraocular pressure measuring device. (a) Identification. An intraocular pressure measuring device is a manual or AC-powered...

  20. 21 CFR 886.4280 - Intraocular pressure measuring device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Intraocular pressure measuring device. 886.4280... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4280 Intraocular pressure measuring device. (a) Identification. An intraocular pressure measuring device is a manual or AC-powered...

  1. 21 CFR 886.4280 - Intraocular pressure measuring device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Intraocular pressure measuring device. 886.4280... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4280 Intraocular pressure measuring device. (a) Identification. An intraocular pressure measuring device is a manual or AC-powered...

  2. 21 CFR 886.4280 - Intraocular pressure measuring device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Intraocular pressure measuring device. 886.4280... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4280 Intraocular pressure measuring device. (a) Identification. An intraocular pressure measuring device is a manual or AC-powered...

  3. 21 CFR 886.4300 - Intraocular lens guide.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraocular lens guide. 886.4300 Section 886.4300...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device intended to be inserted into the eye during surgery to...

  4. 21 CFR 886.4300 - Intraocular lens guide.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Intraocular lens guide. 886.4300 Section 886.4300...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device intended to be inserted into the eye during surgery to...

  5. 21 CFR 886.4300 - Intraocular lens guide.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Intraocular lens guide. 886.4300 Section 886.4300...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device intended to be inserted into the eye during surgery to...

  6. 21 CFR 886.4300 - Intraocular lens guide.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Intraocular lens guide. 886.4300 Section 886.4300...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device intended to be inserted into the eye during surgery to...

  7. 21 CFR 886.4300 - Intraocular lens guide.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Intraocular lens guide. 886.4300 Section 886.4300...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device intended to be inserted into the eye during surgery to...

  8. Acremoxanthone E, a Novel Member of Heterodimeric Polyketides with a Bicyclo[3.2.2]nonene Ring, Produced by Acremonium camptosporum W. Gams (Clavicipitaceae) Endophytic Fungus

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The fungus Acremonium camptosporum was isolated as an endophyte from the leaves of the plant Bursera simaruba. Extracts from cultures of the fungus were shown to have inhibitory effects on the growth of plant pathogenic oomycetes. The chemical compounds in the extracts were identified, and a group...

  9. Importance of intraocular pressure in glaucoma

    NASA Astrophysics Data System (ADS)

    Joos, Karen M.

    1999-06-01

    Glaucoma results in permanent vision loss and affects the peripheral vision initially. It is presented in 22.5 million people worldwide and is the 3rd cause of blindness. Present tonometers are not ideal for intraocular pressure measurements in all eyes. Of concern, PRK and LASIK may result in lower intraocular pressure readings. A challenges now exists for the development of a tonometer which can easily compensate for corneas with many parameters to avoid a future increase in normal-tension glaucoma or glaucoma which is advanced.

  10. Bartonella and intraocular inflammation: a series of cases and review of literature

    PubMed Central

    Kalogeropoulos, Chris; Koumpoulis, Ioannis; Mentis, Andreas; Pappa, Chrisavgi; Zafeiropoulos, Paraskevas; Aspiotis, Miltiadis

    2011-01-01

    Purpose: To present various forms of uveitis and/or retinal vasculitis attributed to Bartonella infection and review the impact of this microorganism in patients with uveitis. Methods: Retrospective case series study. Review of clinical records of patients diagnosed with Bartonella henselae and Bartonella quintana intraocular inflammation from 2001 to 2010 in the Ocular Inflammation Department of the University Eye Clinic, Ioannina, Greece. Presentation of epidemiological and clinical data concerning Bartonella infection was provided by the international literature. Results: Eight patients with the diagnosis of Bartonella henselae and two patients with B. quintana intraocular inflammation were identified. Since four patients experienced bilateral involvement, the affected eyes totaled 14. The mean age was 36.6 years (range 12–62). Uveitic clinical entities that we found included intermediate uveitis in seven eyes (50%), vitritis in two eyes (14.2%), neuroretinitis in one eye (7.1%), focal retinochoroiditis in one eye (7.1%), branch retinal vein occlusion (BRVO) due to vasculitis in one eye (7.1%), disc edema with peripapillary serous retinal detachment in one eye (7.1%), and iridocyclitis in one eye (7.1%). Most of the patients (70%) did not experience systemic symptoms preceding the intraocular inflammation. Antimicrobial treatment was efficient in all cases with the exception of the case with neuroretinitis complicated by anterior ischemic optic neuropathy and tubulointerstitial nephritis. Conclusion: Intraocular involvement caused not only by B. henselae but also by B. quintana is being diagnosed with increasing frequency. A high index of suspicion is needed because the spectrum of Bartonella intraocular inflammation is very large. In our study the most common clinical entity was intermediate uveitis. PMID:21750616

  11. Infant Botulism and Raised Intraocular Pressure.

    PubMed

    Eberly, Matthew D; Uber, Ian; Kieling, Christopher R; Birdsong, Richard H

    2009-11-01

    Infant botulism is an exceedingly rare disease. Because confirmatory laboratory testing is not available for several days after time of presentation, infant botulism remains a clinical diagnosis. The authors demonstrate how raised intraocular pressure may provide an additional clinical clue to making the diagnosis. PMID:19873952

  12. Characterizing intraocular tumors with photoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Xu, Guan; Xue, Yafang; Gursel, Zeynep; Slimani, Naziha; Wang, Xueding; Demirci, Hakan

    2016-03-01

    Intraocular tumors are life-threatening conditions. Long-term mortality from uveal melanoma, which accounts for 80% of primary intraocular tumors, could be as high as 25% depending on the size, ciliary body involvement and extraocular extension. The treatments of intraocular tumors include eye-sparing approaches such as radiotherapy and thermotherapy, and the more aggressive enucleation. The accurate diagnosis of intraocular tumors is thereby critical in the management and follow-up of the patients. The diagnosis of intraocular tumors is usually based on clinical examination with acoustic backscattering based ultrasonography. By analyzing the high frequency fluctuations within the ultrasound (US) signals, microarchitecture information inside the tumor can be characterized. However, US cannot interrogate the histochemical components formulating the microarchitecture. One representative example is the inability of US imaging (and other contemporary imaging modalities as well) in differentiating nevoid and melanoma cells as the two types of cells possesses similar acoustic backscattering properties. Combining optical and US imaging, photoacoustic (PA) measurements encode both the microarchitecture and histochemical component information in biological tissue. This study attempts to characterize ocular tumors by analyzing the high frequency signal components in the multispectral PA images. Ex vivo human eye globes with melanoma and retinoblastoma tumors were scanned using less than 6 mJ per square centimeters laser energy with tunable range of 600-1700 nm. A PA-US parallel imaging system with US probes CL15-7 and L22-14 were used to acquire the high frequency PA signals in real time. Preliminary results show that the proposed method can identify uveal melanoma against retinoblastoma tumors.

  13. Direct ethanol production from glucose, xylose and sugarcane bagasse by the corn endophytic fungi Fusarium verticillioides and Acremonium zeae.

    PubMed

    de Almeida, Maíra N; Guimarães, Valéria M; Falkoski, Daniel L; Visser, Evan M; Siqueira, Germano A; Milagres, Adriane M F; de Rezende, Sebastião T

    2013-10-10

    Production of ethanol with two corn endophytic fungi, Fusarium verticillioides and Acremonium zeae, was studied. The yield of ethanol from glucose, xylose and a mixture of both sugars were 0.47, 0.46 and 0.50g/g ethanol/sugar for F. verticillioides and 0.37, 0.39 and 0.48g/g ethanol/sugar for A. zeae. Both fungi were able to co-ferment glucose and xylose. Ethanol production from 40g/L of pre-treated sugarcane bagasse was 4.6 and 3.9g/L for F. verticillioides and A. zeae, respectively, yielding 0.31g/g of ethanol per consumed sugar. Both fungi studied were capable of co-fermenting glucose and xylose at high yields. Moreover, they were able to produce ethanol directly from lignocellulosic biomass, demonstrating to be suitable microorganisms for consolidated bioprocessing. PMID:23942376

  14. The Visual Effects of Intraocular Colored Filters

    PubMed Central

    Hammond, Billy R.

    2012-01-01

    Modern life is associated with a myriad of visual problems, most notably refractive conditions such as myopia. Human ingenuity has addressed such problems using strategies such as spectacle lenses or surgical correction. There are other visual problems, however, that have been present throughout our evolutionary history and are not as easily solved by simply correcting refractive error. These problems include issues like glare disability and discomfort arising from intraocular scatter, photostress with the associated transient loss in vision that arises from short intense light exposures, or the ability to see objects in the distance through a veil of atmospheric haze. One likely biological solution to these more long-standing problems has been the use of colored intraocular filters. Many species, especially diurnal, incorporate chromophores from numerous sources (e.g., often plant pigments called carotenoids) into ocular tissues to improve visual performance outdoors. This review summarizes information on the utility of such filters focusing on chromatic filtering by humans. PMID:24278692

  15. Introduction to the development of intraocular lens

    NASA Astrophysics Data System (ADS)

    Li, Yifan; Peng, Runling; Hu, Shuilan; Wei, Maowei; Chen, Jiabi

    2013-08-01

    In order to cure the cataract disease or injuries in eyes, intraocular lens(IOL) has been studied all the time to replace the crystalline lens in human eyes. Researches on IOL are started early from 19th century, and it develops greatly in the hundreds years after. This article introduces several main kinds of IOLs that appear in the development history of IOL, and raises the double-liquid zoom IOL based on electrowetting, which will be the trend of IOL study.

  16. Isolation of an Acremonium sp. from a screening of 52 seawater fungal isolates and preliminary characterization of its growth conditions and nematicidal activity.

    PubMed

    Meng, QingHeng; Shi, XiaoXun; Meng, FanHuan; Feng, Xin; Sun, JianHua

    2012-10-01

    Fifty-two fungal isolates obtained from seawater were screened for anti-nematode activity. One isolate, an Acremonium sp., exhibited the highest activity against the pinewood nematode, Bursaphelenchus xylophilus. When it was grown at pH 7.0 and 24-26 °C, nematicidal metabolites were produced. These were heat-stable, water-soluble molecules with MWs <6 kDa. Nematicidal activity was highest at neutral pH. PMID:22714270

  17. Case report: intraocular gnathostomiasis in Vietnam.

    PubMed

    Xuan, Le Thi; Rojekittikhun, Wichit; Punpoowong, Benjanee; Trang, Le Nhu; Hien, Tran Vinh

    2002-09-01

    This is the report of the first case of intraocular gnathostomiasis diagnosed in Vietnam. The disease progressed in two months in two distinct phases: in the first phase, the patient had swellings, which appeared at different times and in different locations, on his face--this phase lasted around one month; the second phase was the embedding of the parasite in the vitreous cavity of the right eye and uveitis. Surgical extraction of a living Gnathostoma larva was carried out. Based on morphological, histological criteria, the larva may have been an atypical third-stage of Gnathostoma spinigerum. PMID:12693580

  18. Purification and characterization of an extracellular (1 --> 6)-beta-glucanase from the filamentous fungus Acremonium persicinum.

    PubMed Central

    Pitson, S M; Seviour, R J; McDougall, B M; Stone, B A; Sadek, M

    1996-01-01

    An endo-(1 --> 6)-beta-glucanase has been isolated from the culture filtrates of the filamentous fungus Acremonium persicinum and purified by (NH4)2SO4 precipitation followed by anion-exchange and gel-filtration chromatography. SDS/PAGE of the purified enzyme gave a single band with an apparent molecular mass of 42.7 kDa. The enzyme is a non-glycosylated, monomeric protein with a pI of 4.9 and pH optimum of 5.0. It hydrolysed (1 --> 6)-beta-glucans (pustulan and lutean), initially yielding a series of (1 --> 6)-beta-linked oligoglucosides, consistent with endo-hydrolytic action. Final hydrolysis products from these substrates were gentiobiose and gentiotriose, with all products released as beta-anomers, indicating that the enzyme acts with retention of configuration. The purified enzyme also hydrolysed Eisenia bicyclis laminarin, liberating glucose, gentiobiose, and a range of larger oligoglucosides, through the apparent bydrolysis of (1 --> 6)-beta- and some (1 --> 3)-beta-linkages in this substrate. K(m) values for pustulan, lutean and laminarin were 1.28, 1.38, and 1.67 mg/ml respectively. The enzyme was inhibited by N-acetylimidazole, N-bromosuccinimide, dicyclohexylcarbodi-imide, Woodward's Reagent K, 2-hydroxy-5-nitrobenzyl bromide, KMnO4 and some metal ions, whereas D-glucono-1,5-lactone and EDTA had no effect. PMID:8670160

  19. Transformation of L-tyrosine to L-dopa by a novel fungus, Acremonium rutilum, under submerged fermentation.

    PubMed

    Krishnaveni, R; Rathod, Vandana; Thakur, M S; Neelgund, Y F

    2009-02-01

    The present study deals with the transformation of L-tyrosine to L-dopa by Acremonium rutilum, a fungal tyrosinase producer, isolated from decomposed banana stud. This appears to be the first report on A. rutilum as a polyphenoloxidase producer with both cresolase and catecholase activity. Enriched Czapek-Dox agar was used for plate assay screening. Enriched potato dextrose broth was used for optimization studies, which induced high levels of L-dopa under submerged fermentation. A. rutilum gave the maximum L-dopa production (0.89 mg/ml) and tyrosinase activity (1095 U/mg) under the optimized parameters, that is, a temperature of 25 degrees C, pH 5.5, an inoculum size of 2.5 ml, and an incubation time of 72-120 h, with L-tyrosine (5 mg/ml) as substrate. Five resolved bands, with R(f) values of 0.73, 0.60, 0.54, 0.37, and 0.26, were observed, which confirmed the presence of L-dopa. This study involves the elevated profile of L-dopa production. Such study is needed, as L-dopa has the ability to control Parkinson's disease. PMID:19123033

  20. On the retinal toxicity of intraocular glucocorticoids.

    PubMed

    Torriglia, Alicia; Valamanesh, Fatemeh; Behar-Cohen, Francine

    2010-12-15

    Corticosteroids are hormones involved in many physiological responses such as stress, immune modulation, protein catabolism and water homeostasis. The subfamily of glucocorticoids is used systemically in the treatment of inflammatory diseases or allergic reactions. In the eye, glucocorticoides are used to treat macular edema, inflammation and neovascularization. The most commonly used glucocorticoid is triamcinolone acetonide (TA). The pharmaceutical formulation of TA is not adapted for intravitreal administration but has been selected by ophthalmologists because its very low intraocular solubility provides sustained effect. Visual benefits of intraocular TA do not clearly correlate with morpho-anatomical improvements, suggesting potential toxicity. We therefore studied, non-common, but deleterious effects of glucocorticoids on the retina. We found that the intravitreal administration of TA is beneficial in the treatment of neovascularization because it triggers cell death of endothelial cells of neovessels by a caspase-independent mechanism. However, this treatment is toxic for the retina because it induces a non-apoptotic, caspase-independent cell death related to paraptosis, mostly in the retinal pigmented epithelium cells and the Müller cells. PMID:20654583

  1. Severe South American Ocular Toxoplasmosis Is Associated with Decreased Ifn-γ/Il-17a and Increased Il-6/Il-13 Intraocular Levels

    PubMed Central

    de-la-Torre, Alejandra; Sauer, Arnaud; Pfaff, Alexander W.; Bourcier, Tristan; Brunet, Julie; Speeg-Schatz, Claude; Ballonzoli, Laurent; Villard, Odile; Ajzenberg, Daniel; Sundar, Natarajan; Grigg, Michael E.

    2013-01-01

    In a cross sectional study, 19 French and 23 Colombian cases of confirmed active ocular toxoplasmosis (OT) were evaluated. The objective was to compare clinical, parasitological and immunological responses and relate them to the infecting strains. A complete ocular examination was performed in each patient. The infecting strain was characterized by genotyping when intraocular Toxoplasma DNA was detectable, as well as by peptide-specific serotyping for each patient. To characterize the immune response, we assessed Toxoplasma protein recognition patterns by intraocular antibodies and the intraocular profile of cytokines, chemokines and growth factors. Significant differences were found for size of active lesions, unilateral macular involvement, unilateral visual impairment, vitreous inflammation, synechiae, and vasculitis, with higher values observed throughout for Colombian patients. Multilocus PCR-DNA sequence genotyping was only successful in three Colombian patients revealing one type I and two atypical strains. The Colombian OT patients possessed heterogeneous atypical serotypes whereas the French were uniformly reactive to type II strain peptides. The protein patterns recognized by intraocular antibodies and the cytokine patterns were strikingly different between the two populations. Intraocular IFN-γ and IL-17 expression was lower, while higher levels of IL-13 and IL-6 were detected in aqueous humor of Colombian patients. Our results are consistent with the hypothesis that South American strains may cause more severe OT due to an inhibition of the protective effect of IFN-γ. PMID:24278490

  2. Intraocular Implants for the Treatment of Autoimmune Uveitis

    PubMed Central

    Lee, Darren J.

    2015-01-01

    Uveitis is the third leading cause of blindness in developed countries. Currently, the most widely used treatment of non-infectious uveitis is corticosteroids. Posterior uveitis and macular edema can be treated with intraocular injection of corticosteroids, however, this is problematic in chronic cases because of the need for repeat injections. Another option is systemic immunosuppressive therapies that have their own undesirable side effects. These systemic therapies result in a widespread suppression of the entire immune system, leaving the patient susceptible to infection. Therefore, an effective localized treatment option is preferred. With the recent advances in bioengineering, biodegradable polymers that allow for a slow sustained-release of a medication. These advances have culminated in drug delivery implants that are food and drug administration (FDA) approved for the treatment of non-infectious uveitis. In this review, we discuss the types of ocular implants available and some of the polymers used, implants used for the treatment of non-infectious uveitis, and bioengineered alternatives that are on the horizon. PMID:26264035

  3. A 20-gauge intraocular electromagnetic tip for simplified intraocular foreign-body extraction.

    PubMed

    May, D R; Noll, F G; Munoz, R

    1989-02-01

    A modified tip for the Bronson intraocular electromagnet has been developed. The tip was machined to a 20-gauge cylinder that can be inserted readily into the eye either through an entrance wound or through a pars plana incision. Placement of the tip of the magnet inside the eye allows the foreign body to impact the tip of the magnet rather than the wall of the eye. PMID:2916983

  4. Insect Feeding Deterrents in Endophyte-Infected Tall Fescue †

    PubMed Central

    Johnson, M. C.; Dahlman, D. L.; Siegel, M. R.; Bush, L. P.; Latch, G. C. M.; Potter, D. A.; Varney, D. R.

    1985-01-01

    The presence of an endophytic fungus, Acremonium coenophialum, in tall fescue (Festuca arundinacea) deterred aphid feeding by Rhopalosiphum padi and Schizaphis graminum. Both species of aphid were unable to survive when confined to endophyte-infected tall fescue plants. Feeding deterrents and toxic factors to R. padi and Oncopeltus fasciatus, large milkweed bug, were primarily associated with a methanol extract obtained when endophyte-infected tall fescue seed was serially extracted with hexane, ethyl acetate, and methanol. The concentrations of pyrrolizidine alkaloids were determined to be 30 to 100 times greater in the methanol extract than in the hexane and ethyl acetate extracts. PMID:16346751

  5. Intraocular lens employed for cataract surgery

    NASA Astrophysics Data System (ADS)

    Roszkowska, A. M.; Torrisi, L.

    2014-04-01

    The aim of this paper is to illustrate the techniques of cataract surgery with implantation of intraocular lenses and some physical properties of the used materials. The new technology, coupled with extensive experience and the studied cases, permits to increase the standardization and accuracy of the engravings, by reducing the use and handling of surgical instruments inside the eye. At present it is possible to replace the cataract with crystalline lenses based on biopolymers such as PMMA, silicone, acrylic hydrophilic and hydrophobic acrylic. These materials are increasingly able to replace the natural lens and to ensure the fully functional of the eye. The role of femtosecond lasers in cataract surgery, to assist or replace several aspects of the manual cataract surgery, are discussed.

  6. Primary orbital neuroblastoma with intraocular extension

    PubMed Central

    Vallinayagam, Muthukrishnan; Rao, Vasudev Anand; Pandian, Datta Gulnar; Akkara, John Davis; Ganesan, Niruban

    2015-01-01

    Neuroblastoma is an undifferentiated malignancy of primitive neuroblasts. Neuroblastoma is among the most common solid tumors of childhood. Orbital neuroblastoma is typically a metastatic tumor. In this case report, we describe a 2-year-old child with a rapidly progressing orbital tumor. Computed tomography revealed an orbital mass lesion with extraocular and intraocular components. An incisional biopsy was done, and a histopathological examination showed features suggestive of neuroblastoma. Systemic workup including ultrasonography of the abdomen, chest roentgenogram, whole body computed tomography, and bone scintigraphy showed no evidence of systemic involvement. The diagnosis of primary orbital neuroblastoma was made, and the child was subjected to chemotherapy followed by rapid melting of the tumor. Neuroblastoma should be considered in the differential diagnosis of childhood orbital tumors. PMID:26576531

  7. Mechanical properties of intra-ocular lenses

    NASA Astrophysics Data System (ADS)

    Ehrmann, Klaus; Kim, Eon; Parel, Jean-Marie

    2008-02-01

    Cataract surgery usually involves the replacement of the natural crystalline lens with a rigid or foldable intraocular lens to restore clear vision for the patient. While great efforts have been placed on optimising the shape and optical characteristics of IOLs, little is know about the mechanical properties of these devices and how they interact with the capsular bag once implanted. Mechanical properties measurements were performed on 8 of the most commonly implanted IOLs using a custom build micro tensometer. Measurement data will be presented for the stiffness of the haptic elements, the buckling resistance of foldable IOLs, the dynamic behaviour of the different lens materials and the axial compressibility. The biggest difference between the lens types was found between one-piece and 3-piece lenses with respect to the flexibility of the haptic elements

  8. Bevacizumab and intraocular tumors: an intriguing paradox

    PubMed Central

    Ly, Long V.; Luyten, Gregorius P.M.; Versluis, Mieke; Grossniklaus, Hans E.; van der Velden, Pieter A.; Jager, Martine J.

    2012-01-01

    Purpose Bevacizumab, a humanized monoclonal antibody to vascular endothelial growth factor-A (VEGF-A), was originally developed as an anti-tumor treatment. In ocular oncology, it is being used to treat macular edema due to radiation retinopathy, but it may also be useful for the treatment of primary uveal melanoma (UM) or its metastases. We determined the effect of bevacizumab on the growth of B16F10 cells inside the eye and on B16F10 and UM cells cultured in vitro. Methods B16F10 melanoma cells were placed into the anterior chamber of the eye of C57Bl/6 mice and tumor growth was monitored after injection of different doses of bevacizumab or mock injection. In addition, the effect of bevacizumab on in vitro growth of B16F10 and human UM cells and on the expression of VEGF-A, GLUT-1, and HIF-1α was evaluated. Results Following intraocular injection of bevacizumab into murine B16 tumor-containing eyes, an acceleration of tumor growth was observed, with the occurrence of anterior chamber hemorrhages. Bevacizumab did not affect proliferation of B16F10 cells in vitro, while it inhibited UM cell proliferation. Expression analysis demonstrated that addition of bevacizumab under hypoxic conditions induced VEGF-A, GLUT-1 and HIF-1α in B16F10 cells as well as in UM cell lines and two of four primary UM tumor cultures. Conclusions In contrast with expectations, intraocular injection of bevacizumab stimulated B16F10 melanoma growth in murine eyes. In vitro exposure of B16 and human UM cells to bevacizumab led to paradoxical VEGF-A upregulation. The use of VEGF inhibitors for treatment of macular edema (due to radiation retinopathy) after irradiation of UM should be considered carefully, because of the possible adverse effects on residual UM cells. PMID:23077404

  9. Computational modeling of intraocular gas dynamics.

    PubMed

    Noohi, P; Abdekhodaie, M J; Cheng, Y L

    2015-01-01

    The purpose of this study was to develop a computational model to simulate the dynamics of intraocular gas behavior in pneumatic retinopexy (PR) procedure. The presented model predicted intraocular gas volume at any time and determined the tolerance angle within which a patient can maneuver and still gas completely covers the tear(s). Computational fluid dynamics calculations were conducted to describe PR procedure. The geometrical model was constructed based on the rabbit and human eye dimensions. SF6 in the form of pure and diluted with air was considered as the injected gas. The presented results indicated that the composition of the injected gas affected the gas absorption rate and gas volume. After injection of pure SF6, the bubble expanded to 2.3 times of its initial volume during the first 23 h, but when diluted SF6 was used, no significant expansion was observed. Also, head positioning for the treatment of retinal tear influenced the rate of gas absorption. Moreover, the determined tolerance angle depended on the bubble and tear size. More bubble expansion and smaller retinal tear caused greater tolerance angle. For example, after 23 h, for the tear size of 2 mm the tolerance angle of using pure SF6 is 1.4 times more than that of using diluted SF6 with 80% air. Composition of the injected gas and conditions of the tear in PR may dramatically affect the gas absorption rate and gas volume. Quantifying these effects helps to predict the tolerance angle and improve treatment efficiency. PMID:26682529

  10. Computational modeling of intraocular gas dynamics

    NASA Astrophysics Data System (ADS)

    Noohi, P.; Abdekhodaie, M. J.; Cheng, Y. L.

    2015-12-01

    The purpose of this study was to develop a computational model to simulate the dynamics of intraocular gas behavior in pneumatic retinopexy (PR) procedure. The presented model predicted intraocular gas volume at any time and determined the tolerance angle within which a patient can maneuver and still gas completely covers the tear(s). Computational fluid dynamics calculations were conducted to describe PR procedure. The geometrical model was constructed based on the rabbit and human eye dimensions. SF6 in the form of pure and diluted with air was considered as the injected gas. The presented results indicated that the composition of the injected gas affected the gas absorption rate and gas volume. After injection of pure SF6, the bubble expanded to 2.3 times of its initial volume during the first 23 h, but when diluted SF6 was used, no significant expansion was observed. Also, head positioning for the treatment of retinal tear influenced the rate of gas absorption. Moreover, the determined tolerance angle depended on the bubble and tear size. More bubble expansion and smaller retinal tear caused greater tolerance angle. For example, after 23 h, for the tear size of 2 mm the tolerance angle of using pure SF6 is 1.4 times more than that of using diluted SF6 with 80% air. Composition of the injected gas and conditions of the tear in PR may dramatically affect the gas absorption rate and gas volume. Quantifying these effects helps to predict the tolerance angle and improve treatment efficiency.

  11. Effects of Different Intensities of Exercise on Intraocular Pressure

    ERIC Educational Resources Information Center

    Rowe, Deryl; And Others

    1976-01-01

    The decrease in intraocular pressure during exercise and the first few minutes of recovery is related to a decrease in blood pH and an increase in blood lactate concentration, not to the intensity of the exercise. (MB)

  12. [The neuroanatomical and physiological bases of variations in intraocular pressure].

    PubMed

    Chiquet, C; Denis, P

    2004-09-01

    Intraocular pressure displays a distinct circadian rhythm in animals and humans, with an increase at night and a decrease during the daytime. In animals, the IOP rhythm has been reported to be synchronized by environmental light and to persist in constant darkness, demonstrating a circadian component controlled by an endogenous pacemaker. The structures involved in the rhythmic regulation of intraocular pressure include the suprachiasmatic nucleus, which controls the activity of sympathetic and parasympathetic ocular innervation. These effectors are responsible for controlling the production (beta-adrenergic system) and the outflow (alpha1-adrenergic, parasympathetic system, prostaglandin) of aqueous humor. The production of aqueous humor is under adrenergic control (alpha1- and beta-receptors). Many neuropeptides such as vasoactive intestinal peptide, substance P, and the atrial natriuretic peptide are also involved in the regulation of intraocular pressure. A better understanding of the circadian regulation of intraocular pressure is needed for an appropriate treatment of ocular hypertension and glaucoma. PMID:15314570

  13. IOL Implants: Lens Replacement and Cataract Surgery (Intraocular Lenses)

    MedlinePlus

    ... by: Kierstan Boyd Reviewed by: Elizabeth Yeu MD Mar. 01, 2016 Before intraocular lenses (IOLs) were developed, ... Foods Rich in Vitamin C Help Curb Cataracts Mar 28, 2016 Los Alimentos Ricos en Vitamina C ...

  14. Intraocular lymphoma after cardiac transplantation: magnetic resonance imaging findings.

    PubMed

    Kim, Yi Kyung; Kim, Hyung-Jin; Woo, Kyung In; Kim, Yoon-Duck

    2013-01-01

    We report a case of intraocular lymphoma in a 65-year-old man, 15 months after cardiac transplantation. On Magnetic Resonance (MR) images, the iris and the anterior chamber of the right eye were found to be involved with an enhancing soft-tissue lesion. To our knowledge, this is the first case of post-transplantation intraocular lymphoma evaluated with MR imaging. PMID:23323042

  15. Systemic chemotherapy as a new conservative treatment for intraocular retinoblastoma.

    PubMed

    Yanagisawa, Takaaki

    2004-02-01

    Retinoblastoma is the most common malignant intraocular tumor in childhood. With advances in the methods for early detection of this disease, the survival rate is over 90% in developed countries. The management of intraocular retinoblastoma has gradually changed over the past few decades. Every effort has been made to save life, with the preservation of the eye and sight, if possible. External beam radiotherapy has been a standard treatment for medium and large, or visually threatening, intraocular retinoblastoma, but it markedly increases the risk of cosmetic deformities and secondary cancer in children with germline RB mutations. For the past decade, primary systemic chemotherapy called "chemoreduction" has been employed to avoid radiotherapy and enucleation. This article gives an overview of the results of current trials of primary chemoreduction for intraocular retinoblastoma, and discusses its role and its limitations in conservative treatment. The article also discusses future directions to expand the indications for this treatment. Many children with advanced intraocular retinoblastoma could be spared external beam radiotherapy and enucleation, mostly as a result of chemoreduction and focal methods. Chemoreduction combined with focal treatments will continue to play an important role in the conservative management of children with intraocular retinoblastoma, possibly even in children with advanced disease, with the combined use of multidrug-resistance modulators. PMID:15162821

  16. Infection.

    PubMed

    Saigal, Gaurav; Nagornaya, Natalya; Post, M Judith D

    2016-01-01

    Imaging is useful in the diagnosis and management of infections of the central nervous system. Typically, imaging findings at the outset of the disease are subtle and nonspecific, but they often evolve to more definite imaging patterns in a few days, with less rapidity than for stroke but faster than for neoplastic lesions. This timing is similar to that of noninfectious inflammatory brain disease, such as multiple sclerosis. Fortunately, imaging patterns help to distinguish the two kinds of processes. Other than for sarcoidosis, the meninges are seldom involved in noninfectious inflammation; in contrast, many infectious processes involve the meninges, which then enhance with contrast on computed tomography (CT) or magnetic resonance imaging (MRI). However, brain infection causes a vast array of imaging patterns. Although CT is useful when hemorrhage or calcification is suspected or bony detail needs to be determined, MRI is the imaging modality of choice in the investigation of intracranial infections. Imaging sequences such as diffusion-weighted imaging help in accurately depicting the location and characterizing pyogenic infections and are particularly useful in differentiating bacterial infections from other etiologies. Susceptibility-weighted imaging is extremely useful for the detection of hemorrhage. Although MR spectroscopy findings can frequently be nonspecific, certain conditions such as bacterial abscesses show a relatively specific spectral pattern and are useful in diagnosing and constituting immediate therapy. In this chapter we review first the imaging patterns associated with involvement of various brain structures, such as the epidural and subdural spaces, the meninges, the brain parenchyma, and the ventricles. Involvement of these regions is illustrated with bacterial infections. Next we illustrate the patterns associated with viral and prion diseases, followed by mycobacterial and fungal infections, to conclude with a review of imaging findings

  17. One-pot bioethanol production from cellulose by co-culture of Acremonium cellulolyticus and Saccharomyces cerevisiae

    PubMed Central

    2012-01-01

    Background While the ethanol production from biomass by consolidated bioprocess (CBP) is considered to be the most ideal process, simultaneous saccharification and fermentation (SSF) is the most appropriate strategy in practice. In this study, one-pot bioethanol production, including cellulase production, saccharification of cellulose, and ethanol production, was investigated for the conversion of biomass to biofuel by co-culture of two different microorganisms such as a hyper cellulase producer, Acremonium cellulolyticus C-1 and an ethanol producer Saccharomyces cerevisiae. Furthermore, the operational conditions of the one-pot process were evaluated for maximizing ethanol concentration from cellulose in a single reactor. Results Ethanol production from cellulose was carried out in one-pot bioethanol production process. A. cellulolyticus C-1 and S. cerevisiae were co-cultured in a single reactor. Cellulase producing-medium supplemented with 2.5 g/l of yeast extract was used for productions of both cellulase and ethanol. Cellulase production was achieved by A. cellulolyticus C-1 using Solka-Floc (SF) as a cellulase-inducing substrate. Subsequently, ethanol was produced with addition of both 10%(v/v) of S. cerevisiae inoculum and SF at the culture time of 60 h. Dissolved oxygen levels were adjusted at higher than 20% during cellulase producing phase and at lower than 10% during ethanol producing phase. Cellulase activity remained 8–12 FPU/ml throughout the one-pot process. When 50–300 g SF/l was used in 500 ml Erlenmeyer flask scale, the ethanol concentration and yield based on initial SF were as 8.7–46.3 g/l and 0.15–0.18 (g ethanol/g SF), respectively. In 3-l fermentor with 50–300 g SF/l, the ethanol concentration and yield were 9.5–35.1 g/l with their yields of 0.12–0.19 (g/g) respectively, demonstrating that the one-pot bioethanol production is a reproducible process in a scale-up bioconversion of cellulose to ethanol. Conclusion A. cellulolyticus

  18. UV laser ablation patterns in intraocular lenses

    NASA Astrophysics Data System (ADS)

    Lagiou, D. P.; Evangelatos, Ch.; Apostolopoulos, A.; Spyratou, E.; Bacharis, C.; Makropoulou, M.; Serafetinides, A. A.

    2013-03-01

    The aim of this work is to investigate the effect of UV solid state laser radiation on intraocular lens (IOL) polymer surfaces as an alternative method to conventional surface shaping techniques for IOLs customization. Laser ablation experiments were performed on PMMA plates and commercially available hydrophobic and hydrophilic acrylic IOLs with the 5th harmonic of a Q-switched Nd:YAG laser (λ=213 nm). Circular arrays of holes were drilled on the polymer surface, covering the centre and the peripheries of the IOL. The morphology of the ablated IOL surface was examined with a conventional optical microscope (Leitz GMBH Wetzlar) and with a scanning electron microscope (SEM, Fei - Innova Nanoscope) at various laser parameters. Quantitative measurements of ablation rates were performed with a contact profilometer (Dektak-150), in which a mechanical stylus scanned across the surface of gold-coated IOLs (after SEM imaging) to measure variationsF in surface height. Laser interaction with IOLs depends on optical and mechanical material properties, in addition to laser radiation parameters. The exact ablation mechanism is discussed. Some polymer materials, depending on their properties, are more susceptible to the photothermal mechanism than the photochemical one or vice versa. In summary, every IOL polymer exhibits specific attributes in its interaction with the 5th harmonic of Nd:YAG laser.

  19. Calcification of intraocular implant lens surfaces.

    PubMed

    Wu, Wenju; Guan, Xiangying; Tang, Ruikang; Hook, Daniel; Yan, Wenyan; Grobe, George; Nancollas, George H

    2004-02-17

    Calcification of octacalcium phosphate [Ca8H2(PO4)6 x 5H2O, OCP] on differently packaged "Ultem" and "Surefold" intraocular implant lens surfaces has been studied in vitro in solutions supersaturated with respect to OCP at pH = 7.10 and 37 degrees C. No mineral deposition was observed on the lenses packaged in Ultem vials even after treatment with behenic acid, one of the fatty acids identified on explanted lenses. Following treatment with behenic acid, nucleation of OCP occurred on the lenses from Surefold vials, which incorporate silicone gaskets; induction periods preceding calcification were about 6 h. No mineralization was found on the lenses in vials with other gasket materials, including polytetrafluoroethylene, fluorocarbon elastomer, and polypropylene. The results of this study indicate that both silicone and fatty acids such as behenic acid play important roles in inducing the in vivo calcification of OCP on IOL lenses; all of the lens treatment steps were necessary for nucleation induction. PMID:15803719

  20. Ocular Biocompatibility of Nitinol Intraocular Clips

    PubMed Central

    Velez-Montoya, Raul; Erlanger, Michael

    2012-01-01

    Purpose. To evaluate the tolerance and biocompatibility of a preformed nitinol intraocular clip in an animal model after anterior segment surgery. Methods. Yucatan mini-pigs were used. A 30-gauge prototype injector was used to attach a shape memory nitinol clip to the iris of five pigs. Another five eyes received conventional polypropylene suture with a modified Seipser slip knot. The authors compared the surgical time of each technique. All eyes underwent standard full-field electroretinogram at baseline and 8 weeks after surgery. The animals were euthanized and eyes collected for histologic analysis after 70 days (10 weeks) postsurgery. The corneal thickness, corneal endothelial cell counts, specular microscopy parameters, retina cell counts, and electroretinogram parameters were compared between the groups. A two sample t-test for means and a P value of 0.05 were use for assessing statistical differences between measurements. Results. The injection of the nitinol clip was 15 times faster than conventional suturing. There were no statistical differences between the groups for corneal thickness, endothelial cell counts, specular microscopy parameters, retina cell counts, and electroretinogram measurements. Conclusions. The nitinol clip prototype is well tolerated and showed no evidence of toxicity in the short-term. The injectable delivery system was faster and technically less challenging than conventional suture techniques. PMID:22064995

  1. Noninvasive intraocular pressure monitoring: current insights

    PubMed Central

    De Smedt, Stefan

    2015-01-01

    Glaucoma is the second leading cause of blindness worldwide and intraocular pressure (IOP) is currently its only modifiable risk factor. Peak IOP has for a long time been considered as a major contributor to glaucoma progression, but its effects may depend not only on its magnitude, but also on its time course. The IOP is nowadays considered to be a dynamic parameter with a circadian rhythm and spontaneous changes. The current practice of punctual measuring the IOP during office hours is therefore a suboptimal approach, which does not take into account the natural fluctuation of IOP. Because of its static nature a single IOP measurement in sitting position fails to document the true range of an individual’s IOP, peak IOP, or variation throughout the day. Phasing means monitoring a patient’s IOP during the daytime or over a 24-hour period. This can provide additional information in the management of glaucoma patients. This review focuses on the current insight of non-invasive IOP monitoring as a method of obtaining more complete IOP profiles. Invasive techniques using an implantable sensor are beyond the scope of this review. PMID:26257509

  2. Optical performance test & analysis of intraocular lenses

    NASA Astrophysics Data System (ADS)

    Choi, Junoh

    Cataract is a condition in the eye that if left untreated, could lead to blindness. One of the effective ways to treat cataract is the removal of the cataractous natural crystalline lens and implantation of an artificial lens called an intraocular lens(IOL). The designs of the IOLs have shown improvements over the years to further imitate natural human vision. A need for an objective testing and analysis tool for the latest IOLs grow with the advancements of the IOLs. In this dissertation, I present a system capable of objective test and analysis of the advanced IOLs. The system consists of (1) Model eye into which an IOL can be inserted to mimic conditions of the human eye. (2) Modulation Transfer Function measurement setup capable of through-focus test for depth of field studies and polychromatic test for study of effects of chromatization. (3) Use of Defocus Transfer Function to simulate depth of field characteristic of rotationally symmetric multifocal designs and extension of the function to polychromatic conditions. (4) Several target imaging experiments for comparison of stray light artifacts and simulation using a non-sequential ray trace package.

  3. Update of intraocular lens implantation in children

    PubMed Central

    Al Shamrani, Mohammed; Al Turkmani, Shahira

    2012-01-01

    Cataract is a common problem that affects the vision in children and a major cause of amblyopia in children. However, the management of childhood cataract is tenuous and requires special considerations especially with regard to intraocular lens (IOL) implantation. Age at which an IOL can be implanted is a controversial issue. Implanting an IOL in very young children carries the risk of severe postoperative inflammation and posterior capsule opacification that may need other surgeries and may affect the vision permanently. Accuracy of the calculated IOL power is affected by the short eyes and the steep keratometric values at this age. Furthermore, choosing an appropriate IOL power is not a straight forward decision as future growth of the eye affects the axial length and keratometry readings which may result in an unexpected refractive error as children age. The aim of this review is to cover these issues regarding IOL implantation in children; indications, timing of implantation, types of IOLs, site of implantation and the power calculations. PMID:23961005

  4. [Intraocular Pressure Sensor Based on a Contact Lens].

    PubMed

    Guo, Xuhong; Pet, Weihua; Yao, Zhaolin; Chen, Yuanfang; Hu, Xiaohui; Chen, Hongda; Zhu, Jingyuan; Wu, Huijuan

    2016-02-01

    Intraocular pressure detection has a great significance for understanding the status of eye health, prevention and treatment of diseases such as glaucoma. Traditional intraocular pressure detection needs to be held in the hospital. It is not only time-consuming to doctors and patients, but also difficult to achieve 24 hour-continuous detection. Microminiaturization of the intraocular pressure sensor and wearing it as a contact lens, which is convenient, comfortable and noninvasive, can solve this problem because the soft contact lens with an embedded micro fabricated strain gauge allows the measurement of changes in corneal curvature to correlate to variations of intraocular pressure. We fabricated a strain gauge using micro-electron mechanical systems, and integrated with the contact lens made of polydimethylsiloxane (PDMS) using injection molding. The experimental results showed that the sensitivity was 100. 7 µV/µm. When attached to the corneal surface, the average sensitivity of sensor response of intraocular pressure can be 125.8 µV/mm Hg under the ideal condition. PMID:27382734

  5. Effects of 2-alkynyladenosine derivatives on intraocular pressure in rabbits.

    PubMed

    Konno, Takashi; Ohnuma, Shin-ya; Uemoto, Kazuhiro; Uchibori, Takehiro; Nagai, Akihiko; Kogi, Kentaro; Endo, Kazuki; Hosokawa, Tomokazu; Nakahata, Norimichi

    2004-02-23

    We evaluated the activities of 2-alkynyladenosine derivatives, relatively selective adenosine A2 receptor agonists, in the intraocular pressure regulation in rabbits. An adenosine A2 receptor agonist 2-[p-(2-carboxyethyl)phenylethylamino]-5'-N-ethylcarboxamidoadenosine (CGS-21680) decreased intraocular pressure, while another A2 receptor agonist 2-(phenylamino)adenosine transiently increased it. The first group of 2-alkynyladenosine derivatives (1-hexyn-1-yl derivatives) caused a transient increase followed by decrease in intraocular pressure, while the second group (1-octyn-1-yl and 6-cyano-1-hexyn-1-yl derivatives) only decreased it. The second group is also effective in the ocular hypertensive models induced by water-loading and alpha-chymotrypsin. The outflow facility was increased by a 1-octyn-1-yl derivative. Both increase and decrease in intraocular pressure induced by 2-alkynyladenosine derivatives were inhibited by an adenosine A2 receptor antagonist 3,7-dimethyl-1-propargylxanthine, but not by an adenosine A1 receptor antagonist 8-cyclopentyl-1,3-dipropyl xanthine. These findings suggest that 2-alkynyladenosine derivatives may affect intraocular pressure via adenosine A2 receptor, and 2-alkynyladenosine derivative-induced ocular hypotension is due to the increase of outflow facility. PMID:14985053

  6. Change in intraocular pressure during scleral depression

    PubMed Central

    Trevino, Richard; Stewart, Brandi

    2014-01-01

    Purpose Manometric studies have found that intraocular pressure (IOP) rises 116–350 mmHg during scleral depression in surgical settings. No information is available regarding the effect of scleral depression on IOP in routine clinical settings. The aim of this study is to quantify the change in IOP that occurs when scleral depression is performed on normal eyes in a routine clinical setting. Methods A total of 28 eyes from 28 normal subjects were included. Tono-Pen tonometry was performed while scleral depression was performed in each of the two quadrants: superotemporal (ST) and inferonasal (IN). A post-procedure IOP measurement was obtained following each scleral depression examination. Both ST and IN quadrants were tested on all eyes, with the quadrant tested first chosen at random (15 ST, 13 IN). Results The mean IOP during scleral depression was 65.3 mmHg ST and 47.8 mmHg IN, with a maximum recorded IOP of 88 mmHg. The mean change in IOP for the ST quadrant was 51.9 ± 17.3 mmHg and 46.4 ± 16.0 mmHg for the right and left eyes, respectively. The mean change in IOP for the IN quadrant was 45.3 ± 22.7 mmHg and 16.8 ± 15.8 mmHg for the right and left eyes, respectively. Conclusions Scleral depression as performed in a routine office setting produces wide fluctuations in IOP and may impair ocular perfusion. Additional studies are needed to determine the long-term consequences of routine scleral depression. PMID:25444648

  7. Immune Escape Mechanisms of Intraocular Tumors

    PubMed Central

    Niederkorn, Jerry Y.

    2009-01-01

    The notion that the immune system might control the growth of tumors was suggested over 100 years ago by the eminent microbiologist Paul Ehrlich. This concept was refined and expanded by Burnet and Thomas fifty years later with their articulation of the “immune surveillance” hypothesis. In its simplest form, the immune surveillance hypothesis suggests that neoplasms arise spontaneously and express novel antigens that are recognized by the immune system, which either eliminates the tumors or restrains their growth. Within the eye, immune responses are controlled and sometimes profoundly inhibited - a condition known as immune privilege. Immune privilege in the eye is the result of a complex array of anatomical, physiological, and immunoregulatory mechanisms that prevent the induction and expression of many immune responses. Tumors arising in the eye would seem to have an advantage in evading immune surveillance due to ocular immune privilege. Uveal melanoma, the most common and malignant intraocular tumor in adults not only benefits from the immune privilege of the eye, but has adopted many of the mechanisms that contribute to ocular immune privilege as a strategy for protecting uveal melanoma cells once they leave the sanctuary of the eye and are disseminated systemically in the form of metastases. Although the immune system possesses a battery of effector mechanisms designed to rid the body of neoplasms, tumors are capable of rapidly evolving and countering even the most sophisticated immunological effector mechanisms. To date, tumors seem to be winning this arms race, but an increased understanding of these mechanisms should provide insights for designing immunotherapy that was envisioned over half a century ago, but has failed to materialize to date. PMID:19563908

  8. Intraocular Pressure, Ethnicity, and Refractive Error

    PubMed Central

    Manny, Ruth E.; Mitchell, G. Lynn; Cotter, Susan A.; Jones-Jordan, Lisa A.; Kleinstein, Robert N.; Mutti, Donald O.; Twelker, J. Daniel; Zadnik, Karla

    2011-01-01

    Purpose The ethnically-diverse Collaborative Longitudinal Evaluation of Ethnicity and Refractive Error (CLEERE) Study cohort provides a unique opportunity to explore associations among intraocular pressure (IOP), ethnicity, and refractive error while adjusting for potential confounding variables. Methods Mixed linear models were used to examine the effect of age, refractive error (cycloplegic autorefraction), ethnicity, sex, and measurement protocol on IOP (Tono-pen) in 3,777 children, aged 6-14 years at their first CLEERE visit (1995-2009). Children who became myopic during follow-up were used to examine the relationship between time since myopia onset and IOP. Clinically meaningful differences in IOP were preset at > 2 mm Hg. Results IOP differed among refractive error categories with higher IOP in children with low/moderate myopia than those with high hyperopia (differences < 1 mm Hg). There was a statistically significant relationship between age and IOP that depended on ethnicity (interaction p<0.0001) and measurement protocol (interaction p<0.0001). The relationship between sex and IOP depended on measurement protocol (interaction p=0.0004). For children who became myopic during follow-up, the adjusted mean IOP showed a significant decline for only Asian (p=0.024) and White children (p=0.004). As with other statistically significant results, these changes in mean adjusted IOPs from two years before to two years after myopia onset were < 2 mm Hg. Conclusions Small but significant differences in IOP by refractive error category were found in this ethnically diverse cohort of children. Relationships between IOP and age, ethnicity, sex, and measurement protocol were complicated by significant interactions between these parameters. Longitudinal analysis of children before and after myopia onset showed changes in IOP over time that varied by ethnicity. Higher IOPs before and at myopia onset were not present in all ethnic groups, with differences before and after

  9. New trends in intraocular lens imaging

    NASA Astrophysics Data System (ADS)

    Millán, María S.; Alba-Bueno, Francisco; Vega, Fidel

    2011-08-01

    As a result of modern technological advances, cataract surgery can be seen as not only a rehabilitative operation, but a customized procedure to compensate for important sources of image degradation in the visual system of a patient, such as defocus and some aberrations. With the development of new materials, instruments and surgical techniques in ophthalmology, great progress has been achieved in the imaging capability of a pseudophakic eye implanted with an intraocular lens (IOL). From the very beginning, optical design has played an essential role in this progress. New IOL designs need, on the one hand, theoretical eye models able to predict optical imaging performance and on the other hand, testing methods, verification through in vitro and in vivo measurements, and clinical validation. The implant of an IOL requires a precise biometry of the eye, a prior calculation from physiological data, and an accurate position inside the eye. Otherwise, the effects of IOL calculation errors or misplacements degrade the image very quickly. The incorporation of wavefront aberrometry into clinical ophthalmology practice has motivated new designs of IOLs to compensate for high order aberrations in some extent. Thus, for instance, IOLs with an aspheric design have the potential to improve optical performance and contrast sensitivity by reducing the positive spherical aberration of human cornea. Monofocal IOLs cause a complete loss of accommodation that requires further correction for either distance or near vision. Multifocal IOLs address this limitation using the principle of simultaneous vision. Some multifocal IOLs include a diffractive zone that covers the aperture in part or totally. Reduced image contrast and undesired visual phenomena, such as halos and glare, have been associated to the performance of multifocal IOLs. Based on a different principle, accommodating IOLs rely on the effort of the ciliary body to increase the effective power of the optical system of the

  10. Aspheric versus Spherical Posterior Chamber Intraocular Lenses

    PubMed Central

    Jafarinasab, Mohammad-Reza; Feizi, Sepehr; Baghi, Ahmad-Reza; Ziaie, Hossein; Yaseri, Mehdi

    2010-01-01

    Purpose To compare spherical aberration and contrast sensitivity function following implantation of four different foldable posterior chamber intraocular lenses (IOLs), namely Sensar, Akreos AO, Tecnis, and AcrySof IQ. Methods In this randomized clinical trial, 68 eyes of 68 patients with senile cataracts underwent phacoemulsification and IOL implantation with Sensar (n=17), Akreos AO (n=17), Tecnis (n=17), or AcrySof IQ (n=17). Uncorrected visual acuity (UCVA) and best spectacle-corrected visual acuity (BSCVA), spherical aberration and contrast sensitivity function (CSF) were compared among the study groups, 3 months after surgery. Results There was no significant difference between the study groups in terms of age (P = 0.21). Mean postoperative BSCVA with Sensar, Akreos AO, Tecnis, and AcrySof IQ was 0.15±0.10, 0.12±0.9, 0.08±0.08, and 0.08±0.07 logMAR, respectively (P=0.08). Spherical aberration measured over a 4 mm pupil was significantly higher with Sensar and Akreos AO than the two other IOLs. The difference between Tecnis and AcrySof IQ was significantly in favor of the former IOL. Over a 6 mm pupil, spherical aberrations were comparable with Sensar and Akreos AO, furthermore spherical aberration was also comparable among eyes implanted with Akreos AO, AcrySof IQ, and Tecnis. Sensar yielded significantly inferior results as compared to Acrysof IQ and Tecnis. CSF with Sensar was inferior to the three aspheric IOLs at the majority of spatial frequencies. Tecnis yielded significantly better mesopic CSF at 1.5 and 3 cycles per degree spatial frequencies. Conclusion Tecnis and AcrySof IQ provided significantly better visual function as compared to Sensar and Akreos AO, especially with smaller pupil size. However, this difference diminished with increasing pupil size. PMID:22737364

  11. Retropupillary iris claw intraocular lens implantation in aphakia for dislocated intraocular lens

    PubMed Central

    Faria, Mun Yueh; Ferreira, Nuno Pinto; Pinto, Joana Medeiros; Sousa, David Cordeiro; Leal, Ines; Neto, Eliana; Marques-Neves, Carlos

    2016-01-01

    Background Nowadays, dislocated intraocular lenses (IOLs) and inadequate capsular support are becoming a challenge for every ophthalmic surgeon. Explantation of dislocated IOL and iris claw IOL (ICIOL) are the techniques that have been used in our ophthalmic department. The aim of this study is to report our technique for retropupillar ICIOL. Methods This study is a retrospective case series. A total of 105 eyes with dislocated IOL from the patients at the Department of Ophthalmology in Santa Maria Hospital, a tertiary reference hospital in Lisbon, Portugal, from January 2012 until January 2016, had been analyzed. Of these 105 eyes, 66 eyes had dislocated one-piece IOL and 39 eyes had dislocated three-piece IOL. The latter underwent iris suture of the same IOL and were excluded from this study. The remaining 66 eyes with dislocated one-piece IOL underwent pars plana vitrectomy, that is, explantation of dislocated IOL through corneal incision and an implantation of retropupillary ICIOL. Operative data and postoperative outcomes included best corrected visual acuity, IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and anterior chamber depth. Results The mean follow-up was 23 months (range: 6–48 months). The mean preoperative best corrected visual acuity was 1.260±0.771 logMAR, and postoperative best corrected visual acuity was 0.352±0.400 logMAR units. Mean vision gain was 0.909 logMar units. The patients had the following complications: 1) retinal detachment was found in one patient, 2) corneal edema was found in three patients, 3) high intraocular pressure was observed in twelve patients, 4) subluxation of the IOL was observed in one patient, and 5) macular edema was found in three eyes. Conclusion The results demonstrate that retropupillary ICIOL is an easy and effective method for the correction of aphakia in patients not receiving capsule support. The safety of this procedure must be interpreted in the context

  12. Evaluation of the motion of surgical instruments during intraocular surgery

    PubMed Central

    Hubschman, J-P; Son, J; Allen, B; Schwartz, S D; Bourges, J-L

    2011-01-01

    Purpose Robot assistance in ocular microsurgery could improve precision, dexterity, save time or prevent complications by task automation, and provide access to ocular surgery in undeserved countries by teleoperation. However, to design robotic devices, the range of motion of surgical instruments needs to be precisely quantified. Methods An electromagnetic tracking system was developed for intraocular surgery in order to quantify the movements of ophthalmic surgeons. Kinematics of surgical steps during phacoemulsification and pars plana vitrectomy procedures were determined by measuring the maximum translation and angular range of motion of intraocular surgical tools in the three planes. Conclusion Important variations in amplitudes of rotation and translation were measured between both hands and between surgical tasks. These parameters may be used to develop a robotic intraocular surgical system or to improve training. PMID:21527954

  13. Late-onset Citrobacter koseri endophthalmitis with suture exposure after secondary intraocular lens implantation.

    PubMed

    Kang, Hae Min; Chung, Eun Jee

    2011-08-01

    A 54-year-old male patient was seen in clinic for ocular pain and decreased vision in the right eye with duration of two days. He underwent a cataract operation for his right eye 12 years ago, then a sclera-fixated secondary intraocular implantation and pars plana vitrectomy three years ago due to intraocular lens dislocation. At the initial visit, his visual acuity was restricted to the perception of hand motion. An edematous cornea, cells, flare with hypopyon, and exposed suture material at were observed at the six o'clock direction by slit lamp. Vitreous opacity was noted from B-scan ultrasonography. The patient was diagnosed with late-onset endophthalmitis and an intravitreal cocktail injection was done. On the next day, the hypopyon was aggravated, and therefore a pars plana vitrectomy was performed. A vitreous culture tested positive for Citrobacter koseri. After 12 weeks, the best corrected visual acuity of the right eye improved to 0.7 and a fundus examination revealed a relatively normal optic disc and retinal vasculature. We herein report the first case of endophthalmitis caused by Citrobacter koseri in Korea. Exposed suture material was suspected as the source of infection in this case and prompt surgical intervention resulted in a relatively good visual outcome. PMID:21860579

  14. Late-Onset Citrobacter koseri Endophthalmitis with Suture Exposure after Secondary Intraocular Lens Implantation

    PubMed Central

    Kang, Hae Min

    2011-01-01

    A 54-year-old male patient was seen in clinic for ocular pain and decreased vision in the right eye with duration of two days. He underwent a cataract operation for his right eye 12 years ago, then a sclera-fixated secondary intraocular implantation and pars plana vitrectomy three years ago due to intraocular lens dislocation. At the initial visit, his visual acuity was restricted to the perception of hand motion. An edematous cornea, cells, flare with hypopyon, and exposed suture material at were observed at the six o'clock direction by slit lamp. Vitreous opacity was noted from B-scan ultrasonography. The patient was diagnosed with late-onset endophthalmitis and an intravitreal cocktail injection was done. On the next day, the hypopyon was aggravated, and therefore a pars plana vitrectomy was performed. A vitreous culture tested positive for Citrobacter koseri. After 12 weeks, the best corrected visual acuity of the right eye improved to 0.7 and a fundus examination revealed a relatively normal optic disc and retinal vasculature. We herein report the first case of endophthalmitis caused by Citrobacter koseri in Korea. Exposed suture material was suspected as the source of infection in this case and prompt surgical intervention resulted in a relatively good visual outcome. PMID:21860579

  15. Comparative expression profiling of genes involved in primary metabolism in high-yield and wild-type strains of Acremonium chrysogenum.

    PubMed

    Han, Shu; Liu, Yan; Xie, Liping; Zhu, Baoquan; Hu, Youjia

    2016-03-01

    Cephalosporin C (CPC) productivity of Acremonium chrysogenum has been improved significantly through classical strain improvement programs. Here, we used transcription and metabolite profiling to address mechanisms underlying CPC production in a high yield (HY) strain. Transcription and metabolite profiling indicated that enzymes involved in amino acid production are higher in abundance in the HY strain. Moreover, results indicate a higher flow of precursors from the glycolysis and gluconeogenesis pathways to serine synthesis at the late stage of fermentation in the HY strain. In addition, less pyruvate would enter the TCA cycle thus favoring valine synthesis. Amino acid production would also benefit from a more active pentose phosphate pathway and γ-amino butyric acid shunt both generating NADPH. Moreover the glyoxylate pathway seems to be more active in the HY strain. These results may provide new leads for CPC strain improvement in industry. PMID:26708072

  16. Animal model experimentation using the expansile hydrogel intraocular lens.

    PubMed

    Siepser, S B; Wieland, M

    1991-07-01

    To determine the biocompatibility of the expansile hydrogel intraocular lens, a two-year animal study was undertaken. After phacoemulsification, hydrogel expansile intraocular lenses were implanted in four Dutch-belted rabbit eyes. Slitlamp examinations revealed minimal anterior chamber reaction and lens synechias. Gross pathology and histology demonstrated hyperplastic residual cortex, but confirmed our clinical impression that the lenses were well tolerated. Electron diffraction energy dispersive X-ray microanalysis revealed deposition of aluminum, silicon, magnesium, and calcium, but there was no evidence of matrix penetration. PMID:1895227

  17. Softec HD hydrophilic acrylic intraocular lens: biocompatibility and precision

    PubMed Central

    Espandar, Ladan; Sikder, Shameema; Moshirfar, Majid

    2011-01-01

    Intraocular lens development is driven by higher patient expectations for ideal visual outcomes. The recently US Food and Drug Administration-approved Softec HD™ lens is an aspheric, hydrophilic acrylic intraocular lens (IOL). The hydrophilic design of the lens is optimized to address dysphotopsia while maintaining biocompatibility, optical clarity, resistance to damage, and resistance to biocontamination. Aspheric lenses decrease postoperative spherical aberration. The addition of the Softec lens provides clinicians with another option for IOL placement; however, randomized comparative studies of this lens to others already on the market remain to be completed. PMID:21311658

  18. Intraocular ophthalmic ointment following clear corneal phacoemulsification: Clinical implications.

    PubMed

    Humayun, Muhammad; Gottlieb, Chloe C; Rafuse, Paul E

    2006-12-01

    We report 4 cases of apparent ophthalmic ointment in the anterior chamber after sutureless clear corneal phacoemulsification and posterior chamber intraocular lens implantation. The cases, as well as previous literature, indicate that ointment for topical use can be well tolerated in the eye, although glaucoma and uveitis can be potential negative outcomes. Possible risk factors, some of which may be related to current rates of endophthalmitis after clear corneal cataract surgery, and methods to prevent intraocular ophthalmic ointment after cataract surgery are discussed. PMID:17137997

  19. Development and experimental verification of an intraocular scattering model

    NASA Astrophysics Data System (ADS)

    Jiang, Chong-Jhih; Jhong, Tian-Siang; Chen, Yi-Chun; Sun, Ching-Cherng

    2011-10-01

    An intraocular scattering model was constructed in human eye model and experimentally verified. According to the biometric data, the volumetric scattering in crystalline lens and diffusion at retina fundus were developed. The scattering parameters of cornea, including particle size and obscuration ratio, were varied to make the veiling luminance of the eye model matching the CIE disability glare general formula. By replacing the transparent lens with a cataractous lens, the disability glare curve of cataracts was generated and compared with that of transparent lenses. The MTF of the intraocular scattering model showed nice correspondence with the data measured by a double-pass experiment.

  20. Coaxially sighted intraocular lens light reflex for centration of the multifocal single piece intraocular lens.

    PubMed

    Melki, Samir A; Harissi-Dagher, Mona

    2011-08-01

    Centration of multifocal Intraocular lenses (IOL) may be critical to ensure optimal function and prevent untoward side effects. Pharmacologic pupillary dilation and constriction may shift the physiologic location of the pupillary center rendering intraoperative positioning of multifocal IOL challenging. Similarly, the anterior capsular center is difficult to pinpoint and may not correspond to either the visual axis or the pupillary center. The visual axis is the only landmark that can be consistently identified prior, during and after cataract surgery. Centering diffractive multifocal IOL on the visual axis may allow more consistent placement and better outcome measures. In the following, we describe a simple technique to center multifocal single piece acrylic IOLs on the visual axis. PMID:21816250

  1. An overview of the taxonomy, phylogeny, and typification of nectriaceous fungi in Cosmospora, Acremonium, Fusarium, Stilbella, and Volutella.

    PubMed

    Gräfenhan, T; Schroers, H-J; Nirenberg, H I; Seifert, K A

    2011-01-01

    A comprehensive phylogenetic reassessment of the ascomycete genus Cosmospora (Hypocreales, Nectriaceae) is undertaken using fresh isolates and historical strains, sequences of two protein encoding genes, the second largest subunit of RNA polymerase II (rpb2), and a new phylogenetic marker, the larger subunit of ATP citrate lyase (acl1). The result is an extensive revision of taxonomic concepts, typification, and nomenclatural details of many anamorph- and teleomorph-typified genera of the Nectriaceae, most notably Cosmospora and Fusarium. The combined phylogenetic analysis shows that the present concept of Fusarium is not monophyletic and that the genus divides into two large groups, one basal in the family, the other terminal, separated by a large group of species classified in genera such as Calonectria, Neonectria, and Volutella. All accepted genera received high statistical support in the phylogenetic analyses. Preliminary polythetic morphological descriptions are presented for each genus, providing details of perithecia, micro- and/or macro-conidial synanamorphs, cultural characters, and ecological traits. Eight species are included in our restricted concept of Cosmospora, two of which have previously documented teleomorphs and all of which have Acremonium-like microconidial anamorphs. A key is provided to the three anamorphic species recognised in Atractium, which is removed from synonymy with Fusarium and epitypified for two macroconidial synnematous species and one sporodochial species associated with waterlogged wood. Dialonectria is recognised as distinct from Cosmospora and two species with teleomorph, macroconidia and microconidia are accepted, including the new species D. ullevolea. Seven species, one with a known teleomorph, are classified in Fusicolla, formerly considered a synonym of Fusarium including members of the F. aquaeductuum and F. merismoides species complex, with several former varieties raised to species rank. Originally a section of

  2. An overview of the taxonomy, phylogeny, and typification of nectriaceous fungi in Cosmospora, Acremonium, Fusarium, Stilbella, and Volutella

    PubMed Central

    Gräfenhan, T.; Schroers, H.-J.; Nirenberg, H.I.; Seifert, K.A.

    2011-01-01

    A comprehensive phylogenetic reassessment of the ascomycete genus Cosmospora (Hypocreales, Nectriaceae) is undertaken using fresh isolates and historical strains, sequences of two protein encoding genes, the second largest subunit of RNA polymerase II (rpb2), and a new phylogenetic marker, the larger subunit of ATP citrate lyase (acl1). The result is an extensive revision of taxonomic concepts, typification, and nomenclatural details of many anamorph- and teleomorph-typified genera of the Nectriaceae, most notably Cosmospora and Fusarium. The combined phylogenetic analysis shows that the present concept of Fusarium is not monophyletic and that the genus divides into two large groups, one basal in the family, the other terminal, separated by a large group of species classified in genera such as Calonectria, Neonectria, and Volutella. All accepted genera received high statistical support in the phylogenetic analyses. Preliminary polythetic morphological descriptions are presented for each genus, providing details of perithecia, micro- and/or macro-conidial synanamorphs, cultural characters, and ecological traits. Eight species are included in our restricted concept of Cosmospora, two of which have previously documented teleomorphs and all of which have Acremonium-like microconidial anamorphs. A key is provided to the three anamorphic species recognised in Atractium, which is removed from synonymy with Fusarium and epitypified for two macroconidial synnematous species and one sporodochial species associated with waterlogged wood. Dialonectria is recognised as distinct from Cosmospora and two species with teleomorph, macroconidia and microconidia are accepted, including the new species D. ullevolea. Seven species, one with a known teleomorph, are classified in Fusicolla, formerly considered a synonym of Fusarium including members of the F. aquaeductuum and F. merismoides species complex, with several former varieties raised to species rank. Originally a section of

  3. CUSTOM OPTIMIZATION OF INTRAOCULAR LENS ASPHERICITY

    PubMed Central

    Koch, Douglas D.; Wang, Li

    2007-01-01

    Purpose To investigate the optimal amount of ocular spherical aberration (SA) in an intraocular lens (IOL) to maximize optical quality. Methods In 154 eyes of 94 patients aged 40 to 80 years, implantation of aspheric IOLs was simulated with different amounts of SA to produce residual ocular SA from −0.30 μm to +0.30 μm. Using the VOL-CT program (Sarver & Associates, Carbondale, Illinois), corneal wavefront aberrations up to 6th order were computed from corneal topographic elevation data (Humphrey Atlas, Carl Zeiss Meditec, Inc, Dublin, California). Using the ZernikeTool program (Advanced Medical Optics, Inc, Santa Ana, California), the polychromatic point spread function with Stiles-Crawford effect was calculated for the residual ocular higher-order aberrations (HOAs, 3rd to 6th order, 6-mm pupil), assuming fully corrected 2nd-order aberrations. Five parameters were used to quantify optical image quality, and we determined the residual ocular SA at which the maximal image quality was achieved for each eye. Stepwise multiple regression analysis was performed to assess the predictors for optimal SA of each eye. Results The optimal SA varied widely among eyes. Most eyes had best image quality with low amounts of negative SA. For modulation transfer function volume up to 15 cycles/degree, the amount of optimal SA could be predicted based on other HOAs of the cornea with coefficient of multiple determination (R2) of 79%. Eight Zernike terms significantly contributed to the optimal SA in this model; the order of importance to optimal SA from most to least was: Z60, Z62, Z42, Z53, Z64, Z3−1, Z33, and Z31. For the other 4 measures of visual quality, the coefficients of determination varied from 32% to 63%. Conclusion The amount of ocular SA producing best image quality varied widely among subjects and could be predicted based on corneal HOAs. Selection of an aspheric IOL should be customized according to the full spectrum of corneal HOAs and not 4th-order SA alone

  4. Controversies in intraocular lens implantation in pediatric uveitis.

    PubMed

    Phatak, Sumita; Lowder, Careen; Pavesio, Carlos

    2016-12-01

    Cataract is one of the most common and visually debilitating complications of pediatric uveitis. It develops as a consequence of chronic inflammation and steroid use and is seen most often in juvenile idiopathic arthritis (JIA)-associated uveitis. Cataract extraction with intraocular lens (IOL) insertion has been carried out with a measure of success in non-uveitic pediatric eyes, but in cases of uveitis, multiple factors affect the final outcome. Chronic inflammation and its sequelae such as band keratopathy, posterior synechiae, and cyclitic membranes make surgical intervention more challenging and outcome less certain. Postoperative complications like increased inflammation, glaucoma, posterior capsular opacification, retrolental membranes, and hypotony may compromise the visual outcome. Early refractive correction is imperative in pediatric eyes to prevent amblyopia. The use of contact lenses and intraocular lenses in pediatric uveitic eyes were fraught with complications in the past. Surgical interventions such as vitreo-lensectomy followed by contact lens fitting and small incision cataract surgery followed by different types of intraocular lenses have been utilized, and many reports have been published, albeit in small patient groups. This review analyzes and discusses the existing literature on intraocular lens implantation in cases of pediatric uveitic cataract surgery. PMID:27009616

  5. Telemedicine in the control of intra-ocular pressure.

    PubMed

    Michelson, G; Striebel, W; Prihoda, W; Schmidt, V

    2000-01-01

    Glaucoma is one of the most common causes of blindness in the Western world and a major risk factor is increased intra-ocular pressure. We therefore used telemedicine in its control. Patients measured their intra-ocular pressure several times a day with a portable instrument and the values were then entered into a portable digital assistant. These data were transmitted by a modem to a central server. If the intra-ocular pressure was pathologically high, an email message was automatically sent to the ophthalmologist. The pressure curve, including a statistical analysis, was displayed in an easily readable chart format. Ten patients with glaucoma participated in a trial. Self-tonometry with telemedicine enabled continuous evaluation of the patient by the ophthalmologist. This approach offered the advantage of controlling the treatment remotely. Advantages for the patient were that the measurements were easily done at home under normal conditions, and the patient could control when the measurement and data transmission would be performed. Telemedicine is a cost-effective technique enabling the early diagnosis of pathologically increased intra-ocular pressure. PMID:10793996

  6. Effect of chymase on intraocular pressure in rabbits.

    PubMed

    Konno, Takashi; Maruichi, Midori; Takai, Shinji; Oku, Hidehiro; Sugiyama, Tetsuya; Uchibori, Takehiro; Nagai, Akihiko; Kogi, Kentaro; Ikeda, Tsunehiko; Miyazaki, Mizuo

    2005-11-01

    Chymase is a chymotrypsin-like serine protease that is stored exclusively in the secretory granules of mast cells and converts big endothelins to endothelin-1 (1-31). The aim of this study was to evaluate the effect of chymase on intraocular pressure in rabbits. Chymase injection (3 and 10 mU) resulted in a trend toward increased intraocular pressure and a significant increase in intraocular pressure at a dose of 10 mU compared with the control. A specific chymase inhibitor, Suc-Val-Pro-Phe(P)(OPh)(2), attenuated the ocular hypertension induced by chymase. Endothelin-1 (1-31) also caused ocular hypertension, which was inhibited by a selective endothelin ET(A) receptor antagonist, cyclo(D-Asp-Pro-D-Val-Leu-D-Trp) (BQ-123). Moreover, chymase-induced ocular hypertension was inhibited by BQ-123. These results suggest that chymase influences the regulation of intraocular pressure, and it is likely that the formation of endothelin-1 (1-31) and subsequent activation of endothelin ET(A) receptors are involved in the development of ocular hypertension induced by chymase. PMID:16253233

  7. Intraocular pressure and tear production in five herbivorous wildlife species.

    PubMed

    Ofri, R; Horowitz, I H; Raz, D; Shvartsman, E; Kass, P H

    2002-08-31

    The intraocular pressure and rate of tear production were measured in 18 addax antelopes (Addax nasomaculatus), four impalas (Aepyceros melampus), 11 wide-lipped rhinoceroses (Ceratotherium simum), 10 white-tailed wildebeests (Connochaetes gnou) and seven scimitar-horned oryxes (Oryx dammah). The animals were anaesthetised with an intramuscular injection of etorphine hydrochloride and acepromazine maleate, and the Schirmer tear test I was used to evaluate tear production, and applanation tonometry was used to evaluate the intraocular pressure. The mean (sd) rate of tear production ranged from 17.6 (3.1) mm/minute in the rhinoceros to 28.8 (8.3) mm/minute in the addax. The intraocular pressure ranged from 8.0 (1.2) mmHg in the impala to 32.1 (10.4) mmHg in the rhinoceros. The rate of tear production in the addax and the intraocular pressure in the rhinoceros appear to be the highest values of these variables to have been reported in any species. PMID:12233828

  8. Ultrashort laser ablation of PMMA and intraocular lenses

    NASA Astrophysics Data System (ADS)

    Serafetinides, A. A.; Makropoulou, M.; Fabrikesi, E.; Spyratou, E.; Bacharis, C.; Thomson, R. R.; Kar, A. K.

    2008-10-01

    The use of intraocular lenses (IOLs) is the most promising method to restore vision after cataract surgery. Several new materials, techniques, and patterns have been studied for forming and etching IOLs to improve their optical properties and reduce diffractive aberrations. This study is aimed at investigating the use of ultrashort laser pulses to ablate the surface of PMMA and intraocular lenses, and thus provide an alternative to conventional techniques. Ablation experiments were conducted using various polymer substrates (PMMA samples, hydrophobic acrylic IOL, yellow azo dye doped IOL, and hydrophilic acrylic IOL consist of 25% H2O). The irradiation was performed using 100 fs pulses of 800 nm radiation from a regeneratively amplified Ti:sapphire laser system. We investigated the ablation efficiency and the phenomenology of the ablated patterns by probing the ablation depth using a profilometer. The surface modification was examined using a high resolution optical microscope (IOLs) or atomic force microscope—AFM (PMMA samples). It was found that different polymers exhibited different ablation characteristics, a result that we attribute to the differing optical properties of the materials. In particular, it was observed that the topography of the ablation tracks created on the hydrophilic intraocular lenses was smoother in comparison to those created on the PMMA and hydrophobic lens. The yellow doped hydrophobic intraocular lenses show higher ablation efficiency than undoped hydrophobic acrylic lenses.

  9. Combined aniridic intraocular lens implantation and vitreoretinal surgery

    PubMed Central

    Mehta, Hijab; Jayadev, Chaitra; Natarajan, S

    2007-01-01

    A 45-year-old man presented with post-traumatic aniridia. We describe the combined surgery done to treat both aniridia and epiretinal membrane simultaneously. A combined aniridia intraocular lens and vitreoretinal surgery was done. The case report highlights the advantage of combined surgery in terms of cost factor and surgical time. PMID:17699956

  10. Effects of angiotensin, vasopressin and atrial natriuretic peptide on intraocular pressure in anesthetized rats

    NASA Technical Reports Server (NTRS)

    Palm, D. E.; Shue, S. G.; Keil, L. C.; Balaban, C. D.; Severs, W. B.

    1995-01-01

    The effects of atrial natriuretic peptide (ANP), vasopressin (AVP) and angiotensin (ANG) on blood and intraocular pressures of pentobarbital anesthetized rats were evaluated following intravenous, intracerebroventricular or anterior chamber routes of administration. Central injections did not affect intraocular pressure. Equipressor intravenous infusions of ANG raised, whereas AVP decreased, intraocular pressure. Direct infusions of a balanced salt solution (0.175 microliter/min) raised intraocular pressure between 30 and 60 min. Adding ANG or ANP slightly reduced this solvent effect but AVP was markedly inhibitory. An AVP-V1 receptor antagonist reversed the blunting of the solvent-induced rise by the peptide, indicating receptor specificity. Acetazolamide pretreatment lowered intraocular pressure, but the solvent-induced rise in intraocular pressure and inhibition by AVP still occurred without altering the temporal pattern. Thus, these effects appear unrelated to aqueous humor synthesis rate. The data support the possibility of intraocular pressure regulation by peptides acting from the blood and aqueous humor.

  11. An ultralow power wireless intraocular pressure monitoring system

    NASA Astrophysics Data System (ADS)

    Demeng, Liu; Niansong, Mei; Zhaofeng, Zhang

    2014-10-01

    This paper describes an ultralow power wireless intraocular pressure (IOP) monitoring system that is dedicated to sensing and transferring intraocular pressure of glaucoma patients. Our system is comprised of a capacitive pressure sensor, an application-specific integrated circuit, which is designed on the SMIC 180 nm process, and a dipole antenna. The system is wirelessly powered and demonstrates a power consumption of 7.56 μW at 1.24 V during continuous monitoring, a significant reduction in active power dissipation compared to existing work. The input RF sensitivity is -13 dBm. A significant reduction in input RF sensitivity results from the reduction of mismatch time of the ASK modulation caused by FM0 encoding. The system exhibits an average error of ± 1.5 mmHg in measured pressure. Finally, a complete IOP system is demonstrated in the real biological environment, showing a successful reading of the pressure of an eye.

  12. Intra-ocular pressure normalization technique and equipment

    NASA Technical Reports Server (NTRS)

    Baehr, E. F. (Inventor)

    1979-01-01

    A method and apparatus is described for safely reducing abnormally high intraocular pressure in an eye during a predetermined time interval. This allows maintenance of normal intraocular pressure during glaucoma surgery. A pressure regulator of the spring-biassed diaphragm type is provided with additional bias by a column of liquid. The hypodermic needle can be safely inserted into the anterior chamber of the eye. Liquid is then bled out of the column to reduce the bias on the diaphragm of the pressure regulator and, consequently, the output pressure of the regulator. This lowering pressure of the regulator also occurs in the eye by means of a small second bleed path provided between the pressure regulator and the hypodermic needle.

  13. Determination of heparin on intraocular lens surfaces by ion chromatography.

    PubMed

    Ander, B; Karlsson, A; Ohrlund, A

    2001-05-11

    A sensitive and selective method has been developed for the determination of heparin on heparin coated PMMA, poly(methyl methacrylate), intraocular lenses. Heparin was hydrolysed to glucosamine and glucuronic acid, and the content of glucosamine was determined using ion chromatography with pulsed amperometric detection. In order to verify that a complete hydrolysis was obtained for the heparin on the coated intraocular lenses, electron spectroscopy for chemical analysis (ESCA) was used for analysing traces of sulphur on the lens surfaces. The sensitivity of the method allows quantitative determination of 150 ng of heparin on one individual lens. The new method was compared to a standard spectrophotometric method, measuring the colour intensity of a heparin toluidine blue complex. Correlation between the methods was shown for samples prepared from PMMA lenses coated with different amounts of heparin. PMID:11403462

  14. Intraocular lens exchange-removing the optic intact.

    PubMed

    Lee, Matthew Hao; Webster, Diane Lesley

    2016-01-01

    Current practice for intraocular lens (IOL) exchange is to cut the optic of the posterior chamber intraocular lens (PCIOL) prior to removing it. Great care must be taken during this maneuver to avoid a posterior capsular tear. Removing the haptics from the fibrosed capsule can also be hazardous, as it may result in zonular stress and dehiscence. A technique is described for performing foldable (one-piece acrylic) IOL removal without cutting the optic. Careful visco-dissection of the haptics with a low viscosity ophthalmic viscosurgical device (OVD) in the fibrosed peripheral capsular tunnel avoids zonular or capsular stress. Internal wound enlargement permits foldable IOL removal in one piece, whilst preserving a self-sealing sutureless corneal wound. This technique may enhance the safety and efficacy of foldable IOL exchange. PMID:27366699

  15. An Imaging Review of Intra-ocular Calcifications.

    PubMed

    Kachewar, Sushil G; Kulkarni, Devidas S

    2014-01-01

    Intra-ocular calcifications can occur due to a variety of reasons. In cataract, the lovely lens gets calcified and the bright beautiful world becomes dark and dreadful. Cataract comes in various forms like; congenital, traumatic and senile. Asteroid Hyalosis (AH) occurs because of the accumulation of calcium soaps in vitreous of the eyes. Although it is asymptomatic and unilateral, it is seen more often in diabetic patients. Tumours of eye like retinoblastoma and optic nerve meningioma too are known to show calcifications. This review has focussed on imaging appearances of intra-ocular calcifications, a small process in a small organ that nevertheless has a wide impact on the entire organs. PMID:24596775

  16. Intraocular lens exchange-removing the optic intact

    PubMed Central

    Lee, Matthew Hao; Webster, Diane Lesley

    2016-01-01

    Current practice for intraocular lens (IOL) exchange is to cut the optic of the posterior chamber intraocular lens (PCIOL) prior to removing it. Great care must be taken during this maneuver to avoid a posterior capsular tear. Removing the haptics from the fibrosed capsule can also be hazardous, as it may result in zonular stress and dehiscence. A technique is described for performing foldable (one-piece acrylic) IOL removal without cutting the optic. Careful visco-dissection of the haptics with a low viscosity ophthalmic viscosurgical device (OVD) in the fibrosed peripheral capsular tunnel avoids zonular or capsular stress. Internal wound enlargement permits foldable IOL removal in one piece, whilst preserving a self-sealing sutureless corneal wound. This technique may enhance the safety and efficacy of foldable IOL exchange. PMID:27366699

  17. Intraocular gnathostomiasis: A rare case report from Central India

    PubMed Central

    Rawat, Preeti; Gautam, Manushree; Jain, Nikhila C; Jain, Rajdeep

    2016-01-01

    We report the first case of intraocular gnathostomiasis from Central India. A 29-year-old male from Indore, Madhya Pradesh, presented with pain and redness of the right eye since 1 month. Slit lamp examination revealed anterior uveitis, multiple iris atrophic patches, and a live worm hooked on iris. The worm was removed through a small sclerocorneal tunnel. Microscopy confirmed Gnathostoma spinigerum. The patient was treated with oral albendazole and steroids. The case is reported because of its rarity. PMID:27146938

  18. Intraocular involvement with subretinal pigment epithelium infiltrates by mycosis fungoides.

    PubMed Central

    Erny, B. C.; Egbert, P. R.; Peat, I. M.; Shorrock, K.; Rosenthal, A. R.

    1991-01-01

    We report a case of intraocular mycosis fungoides in a 48-year-old man. The patient presented with decreased visual acuity, white subretinal lesions, and vitritis. Post-mortem histopathology revealed malignant T cell infiltrates consistent with mycosis fungoides in the retina, vitreous, and between the retinal pigment epithelium (RPE) and Bruch's membrane Focal atrophy of the RPE, along with the sub-RPE infiltrates, correlated with the clinically visible fundus lesions. Images PMID:1751471

  19. Endogenous bacterial endophthalmitis masquerading as an intraocular tumor

    PubMed Central

    Salvetti, Anna Paola; Pellegrini, Marco; Bottoni, Ferdinando; Staurenghi, Giovanni

    2015-01-01

    A 40-year-old female patient referred for a possible intraocular tumor was found to have an endogenous bacterial endophthalmitis in her right eye. Fundus examination revealed an amelanotic dome shaped choroidal mass and an exudative retinal detachment. Enhanced Depth Imaging-Optical Coherence Tomography (EDI-OCT), fundus autofluorescence (FAF) and ultrasounds were suggestive of a possible choroidal melanoma. A multimodal imaging approach and a thorough anamnesis were instrumental in establishing the correct diagnosis. PMID:26949365

  20. The dangers of metal-loop intraocular lenses.

    PubMed

    Shepard, D D

    1977-10-01

    The author implanted 500 intraocular lenses (IOLs) during intracapsular surgery. Data from the 60 lenses with metal posterior loops showed a markedly high incidence of complication compared to plastic loops: twice as many overall complications, three times the cystoid mascular edema, three times the rate for subsequent corrective surgical procedures, and 30 times more IOLs had to be removed. IOL manufacturers are advised to abandon metal loops for intracapsular implantation. Polypropylene is suggested as the apparent ideal loop material. PMID:304550

  1. Spontaneous dislocation of intraocular lens as a late complication of uncomplicated cataract surgery: a case series.

    PubMed

    Lam, Hee Hong; Visvaraja, Subrayan

    2012-01-01

    Five patients having uncomplicated phacoemulsification were implanted with CT-Asphina 603P intraocular lenses into the capsular bag. After a few months, three of the patients had haptic flexion anterior to the optic despite minimal capsular fibrosis. One patient had spontaneous dislocation of the intraocular lens into the anterior chamber with only minimal capsular fibrosis. Another patient had one haptic dislocated out of the bag. Late intraocular lens dislocation is also seen in newly designed preloaded intraocular lenses despite the absence of significant capsular fibrosis. Haptic-optic junction design and intraocular lens material play important roles in such complication. A slightly large capsulorhexis might be a deterrent for implantation of this intraocular lens. PMID:21954950

  2. Causes of elevated intraocular pressure following implantation of phakic intraocular lenses for myopia.

    PubMed

    Almalki, Salem; Abubaker, Abdullah; Alsabaani, Nasser A; Edward, Deepak P

    2016-04-01

    The purpose of this study is to present the causes and visual acuity outcomes in patients with elevated intraocular pressure (IOP) following implantable collamer lens (ICL) implantation. A chart review identified patients who developed high IOP at any postoperative examination and a minimum follow-up period of 3 months after ICL implantation. Data are reported out to 6 months postoperatively. Outcome measures included causes of elevated IOP, best-corrected visual acuity (BCVA) at last visit, number of glaucoma medications, other interventions, and glaucomatous damage. Elevated IOP occurred in 58 (10.8 %) of 534 eyes that received ICL. The mean age was 28 ± 7.2 years. The preoperative IOP was 16.3 ± 1.2 mmHg. Elevated IOP most commonly occurred on the first postoperative day (23/58 (39.7 %) eyes) due to retained viscoelastic. This was followed by steroid response in 22/58 (37.9 %) eyes at 2-4 weeks postoperatively. IOP elevation in 6 (10.3 %) eyes was related to high ICL vault and pupillary block, and in 4 (6.9 %) eyes due to synechial angle closure. At last visit, BCVA was 20/40 or better in 56/58 (96.6 %) eyes, and 5/58 (8.6 %) eyes remained on glaucoma medications due to persistent steroid response (2 eyes), synechial angle closure glaucoma (1 eye), and other causes (2 eyes). One eye showed glaucomatous damage. Two eyes with high vault and elevated IOP underwent ICL explantation. There is a moderate risk of transiently developing elevated IOP after ICL implantation. Thorough removal of viscoelastic and use of anti-glaucoma medications during steroid use will reduce the majority of cases with postoperative IOP elevation. PMID:26265323

  3. The preoperative intraocular pressure level predicts the amount of underestimated intraocular pressure after LASIK for myopia

    PubMed Central

    Chihara, E; Takahashi, H; Okazaki, K; Park, M; Tanito, M

    2005-01-01

    Aims: To evaluate the statistical significance of the parameters that affect underestimation of intraocular pressure (IOP) after laser in situ keratomileusis (LASIK) for myopia. Methods: In this prospective case series study, patient age, axial length, preoperative corneal curvature, preoperative central corneal thickness (CCT), preoperative IOP, and ablation depth were studied to determine whether they affect the underestimation of IOP in the right eyes of 100 consecutive patients who underwent LASIK. Results: The preoperative IOP was the most important parameter for an amount of underestimated Goldmann applanation tonometric IOP (GAT) and non-contact tonometric IOP (ncIOP) at 1 month (r = 0.654, p<0.0001, R2 = 0.427, and r = 0.694, p<0.0001, R2 = 0.481, respectively) and 3 months (r = 0.637, p<0.0001, R2 = 0.406, and r = 0.726, p<0.0001, R2 = 0.527, respectively). Patient age was statistically significant for underestimating the GAT at 1 month, and both the ablation depth and CCT were statistically significant parameters for underestimating the ncIOP at 1 month and at 3 months by stepwise multiple regression analysis (F>4.000). However, these parameters had small bivariate correlation coefficients, and were considered as minor parameters. Conclusion: Preoperative IOP is the most important parameter that affects an underestimation of IOP after LASIK for myopia. Eyes with a higher true IOP have a larger underestimation of the IOP after LASIK for myopia. From these results, the importance of the modulus of elasticity on IOP measurements was discussed. PMID:15665345

  4. Sustained Release Intraocular Drug Delivery Devices for Treatment of Uveitis

    PubMed Central

    Haghjou, Nahid; Soheilian, Masoud; Abdekhodaie, Mohammad Jafar

    2011-01-01

    Corticosteroids have been the mainstay of uveitis therapy. When intraocular inflammation is unresponsive to steroids, or steroid related side effects become a concern, steroid-sparing medications may be administered which can be classified into immunosuppressive and immunomodulatory agents. Uveitis treatment can be delivered systemically, topically, periocularly or intraocularly. All of the above mentioned medications can entail significant systemic side effects, particularly if administered for prolonged durations, which may become treatment-limiting. Some medications, particularly hydrophobic compounds, may poorly cross the blood–retinal barrier. Topical medications, which have the least side effects, do not penetrate well into the posterior segment and are unsuitable for posterior uveitis which is often sight-threatening. Intraocular or periocular injections can deliver relatively high doses of drug to the eye with few or no systemic side effects. However, such injections are associated with significant complications and must often be repeated at regular intervals. Compliance with any form of regular medication can be a problem, particularly if its administration is associated with discomfort or if side effects are unpleasant. To overcome the above-mentioned limitations, an increasing number of sustained-release drug delivery devices using different mechanisms and containing a variety of agents have been developed to treat uveitis. This review discusses various current and future sustained-release ophthalmic drug delivery systems for treatment of uveitis. PMID:22454753

  5. Validation of sensor for postoperative positioning with intraocular gas

    PubMed Central

    Brodie, Frank L; Woo, Kelly Y; Balakrishna, Ashwin; Choo, Hyuck; Grubbs, Robert H

    2016-01-01

    Purpose Surgical repair of retinal attachment or macular hole frequently requires intraocular gas. This necessitates specific postoperative positioning to improve outcomes and avoid complications. However, patients struggle with correct positioning. We have developed a novel sensor to detect the position of the gas bubble in the eye and provide feedback to patients in real time. In this paper, we determine the specificity and sensitivity of our sensor in vitro using a model eye. Methods We assessed the reliability of our sensor to detect when a gas bubble has deviated off a model retinal break in a model eye. Various bubble sizes representing the intraocular kinetics of sulfur hexafluoride gas and varying degrees of deviation from the correct position were tested using the sensor attached to a mannequin head with a model eye. Results We recorded 36 data points. The sensor acted appropriately in 33 (91.7%) of them. The sensor triggered the alarm every time the bubble deviated off the break (n=15, sensitivity =100%). However, it triggered the alarm (falsely) 3/21 times when the bubble was correctly positioned over the retinal break (specificity =86%). Conclusion Our device shows excellent sensitivity (100%) and specificity (86%) in detecting whether intraocular gas is tamponading a retinal break in a model eye. PMID:27307698

  6. Development of Microelectromechanical Systems (MEMS) forceps for intraocular surgery

    PubMed Central

    Bhisitkul, R B; Keller, C G

    2005-01-01

    Aim: To develop silicon microforceps for intraocular surgery using Microelectromechanical Systems (MEMS) technology, the application of microchip fabrication techniques for the production of controllable three dimensional devices on the micrometre scale. Methods: Prototype MEMS forceps were designed and manufactured for intraocular surgery. Scanning electron microscopy was used to evaluate device tip construction. Designs using both thermal expansion actuators and conventional mechanical activation were tested in human cadaver eyes and in vivo rabbit eyes to assess functionality in standard vitreoretinal surgery. Results: MEMS forceps were constructed with various tip designs ranging from 100 μm to 2 mm in length. Scanning electron microscopy confirmed accurate construction of micro features such as forceps teeth as small as tens of micrometres. In surgical testing, the silicon forceps tips were effective in surgical manoeuvres, including grasping retinal membranes and excising tissue. The mechanical actuator design on a 20 gauge handle was more operational in the intraocular environment than the thermal expansion actuator design. While handheld operation was possible, the precision of the forceps was best exploited when mounted on a three axis micromanipulator. Conclusion: MEMS microforceps are feasible for conventional vitreoretinal surgery, and offer advances in terms of small scale, operating precision, and construction tolerance. PMID:16299136

  7. Varifocal optics for a novel accommodative intraocular lens

    NASA Astrophysics Data System (ADS)

    Simonov, A. N.; Rombach, M.; Vdovin, G.; Loktev, M.

    2006-01-01

    The development of adaptive optics for the human eye to correct aberrations, to restore accommodation after lens extraction due to cataract and to correct age-related presbyopia have interest of academia and industry. We report on optics for a new accommodative intraocular lens which uses a two-element varifocal Alvarez lens. This lens has two refractive elements with cubic surfaces which, in combination, form a varifocal lens when the elements are shifted relatively to each other perpendicular to the optical path. The accommodative function of the lens will be driven by the ocular ciliary muscle. The refractive elements of the dual-optic intraocular lens are designed to provide a near emmetropic on-axis vision with a >4 dioptre accommodation range. The anterior element has a spherical lens to correct for the overall refraction of the eye, aspheric terms to correct the corneal asphericity and a cubic term as accommodative component; the posterior element has a cubic shaped surface only. The modular transfer function shows that the image on the retina reaches a diffraction limited performance for the on-axis vision in combination with the aspheric correction for aberrations of the cornea. We conclude that the varifocal lens is uniquely suitable for application as an intraocular accommodative lens because of its optical quality and ample accommodative power.

  8. [The Use of Polymers for Intraocular Lenses in Cataract Surgery].

    PubMed

    Fizia-Orlicz, Anna; Misiuk-Hojło, Marta

    2015-01-01

    According to the World Health Organization, cataract remains the leading cause of the curable visual impairment worldwide. Cataract can only be cured by surgery during which the cloudy lens is replaced with an artificial intraocular lens. It is one of the most common surgeries being performed worldwide. There are age-related, congenital, traumatic and metabolic types of cataract which have been distinguished. Age-related cataract is the most common one and it affects people over 60 with the greatest frequency. In reference to patients whose cornea does not fulfill the requirements for a standard refractive surgery, the number of refractive intraocular lens replacement is increasing. Manufacturers aim to enhance materials in order to minimize surgical complication while increasing the patient’s eyesight. The increase in average lifespan along with patients’ expectations stimulate competition among manufacturers who bring new products and solutions into to the market. There is an augmented demand for premium lenses such as toric, multifocal or accommodating. These lenses bring patients the promise of life without the need for wearing glasses. As far as the main materials used in the production of intraocular lens are concerned, there are hydrophobic, hydrophilic, acrylic and silicone lenses in use. In this paper the author discusses characteristics as well as advantages and disadvantages of the above-mentioned materials. The associated surgical complications and the new areas of development regarding the materials used in lenses manufacturing are also examined. PMID:26994891

  9. Raised intraocular pressure with topical steroids after trabeculectomy.

    PubMed

    Thomas, R; Jay, J L

    1988-01-01

    A prospective study of 87 eyes of 52 patients with primary open-angle glaucoma showed a significant steroid-induced rise in intraocular pressure in the 4 weeks after trabeculectomy in 23% of eyes. The steroid response rate was lower (17%) in those eyes that had trabeculectomy without a prior trial of medical therapy than in those who had surgery only after failure of medical therapy (36%), but this difference just failed to reach statistical significance. The responders were not significantly different from the non-responders as regards level of intraocular pressure or severity of visual field loss at diagnosis. The frequency of response was lower than that expected in the normal and in the glaucoma population and fell further in the late post-operative period when only 3 of 8 previously responsive eyes submitted to re-challenge with topical steroids showed persisting responsiveness. Topical steroids may be the commonest cause of high intraocular pressure in the first weeks or even days after trabeculectomy. Decisions about long-term supplementary medical therapy should therefore only be taken several weeks after withdrawal of the post-operative steroid drops. PMID:3169586

  10. Production and characterization of cellulases and hemicellulases by Acremonium cellulolyticus using rice straw subjected to various pretreatments as the carbon source.

    PubMed

    Hideno, Akihiro; Inoue, Hiroyuki; Tsukahara, Kenichiro; Yano, Shinichi; Fang, Xu; Endo, Takashi; Sawayama, Shigeki

    2011-02-01

    Cellulases and hemicellulases are key enzymes in the production of alternative fuels and chemicals from lignocellulosic biomass-an abundant renewable resource. Carbon source selection is an important factor in the production of cellulases and hemicellulases. Rice straw--a potential ethanol source--has recently gained considerable interest in Asian countries. Here, we investigated the production of cellulases by using rice straw subjected to various pretreatments as substrates in order to produce cellulases at low costs; we also identified the enzymes' characteristics. Rice straw cutter milled to <3mm was pretreated by wet disk milling, dry ball milling, or hot-compressed water treatment (HCWT). Pretreated rice straw and commercial cellulose, Solka Floc (SF), were used as carbon sources for cellulase production by the fungus Acremonium cellulolyticus. Filter paper cellulase, β-xylanase, and β-xylosidase production from ball- and disk-milled samples were higher than those from SF. Enzymatic activity was absent in cultures where HCWT rice straw was used as carbon source. Wet disk-milled rice straw cultures were more suitable for enzymatic hydrolysis of pretreated rice straw than SF cultures. Thus, wet disk milling may be a suitable pretreatment for producing substrates for enzymatic hydrolysis and generating inexpensive carbon sources for cellulase production. PMID:22112826

  11. Keeping an eye on dialysis: the association of hemodialysis with intraocular hypertension.

    PubMed

    William, Jeffrey H; Gilbert, Aubrey L; Rosas, Sylvia E

    2015-11-01

    Intraocular hypertension is common during hemodialysis. Dialysis disequilibrium syndrome and intraocular hypertension occur via similar pathophysiologic mechanisms. These mechanisms may contribute to the development of glaucoma and cataracts in a patient population already at high risk for ocular abnormalities, given the common risk factors for chronic kidney disease and impaired aqueous humor outflow. We describe a patient with complicated diabetes mellitus, end-stage renal disease, and recent cataract surgery who developed severe intraocular hypertension during hemodialysis. We recommend increased awareness of the symptoms of intraocular hypertension and subsequent ophthalmologic surveillance in order to prevent long-term visual complications. PMID:26042412

  12. Sutureless, Glueless, Scleral Fixation of Single-Piece and Toric Intraocular Lens: A Novel Technique

    PubMed Central

    Kelkar, Aditya; Shah, Rachana; Kelkar, Jai; Kelkar, Shreekant; Arora, Ekta

    2015-01-01

    Sutureless, glueless, scleral fixation of an intraocular lens is a known technique of fixing a lens in the scleral pockets. However, this technique is applied to single-piece and toric lenses instead of 3-piece lenses, allowing the advantage of the use of premium lenses in patients with poor capsular support. Favourable results without complications of pigment dispersion, iris transillumination defects, dysphotopsia, elevated intraocular pressure, intraocular hemorrhage and cystoid macular edema with a well-centered, stable intraocular lens have been observed in the 3-month postoperative period in both cases. PMID:26327909

  13. Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens

    PubMed Central

    Lee, Shinwook; Choi, Myoung; Xu, Zaiwei; Zhao, Zeyu; Alexander, Elsinore; Liu, Yueai

    2016-01-01

    Purpose The purpose of this study is to compare the optical characteristics of the novel PanOptix presbyopia-correcting trifocal intraocular lens (IOL) and the multifocal ReSTOR +3.0 D IOL, through in vitro bench investigations. Methods The optical characteristics of AcrySof® IQ PanOptix™ (PanOptix) and AcrySof® IQ ReSTOR +3.0 D (ReSTOR +3.0 D) IOLs were evaluated by through-focus Badal images, simulated headlight images, and modulation transfer function (MTF) measurements which determine resolution, photic phenomena, and image quality. Through-focus Badal images of an Early Treatment of Diabetic Retinopathy Study chart were recorded at both photopic and mesopic pupil sizes. Simulated headlight images were taken on an MTF bench with a 50-μm pinhole target and a 5.0 mm pupil at the distance focus of the IOL. MTF curves were measured with a 3.0 mm pupil, and spatial frequencies equivalent to 20/40 and 20/20 visual acuities were recorded to illustrate the through-focus MTF curves. Far-, intermediate-, and near-focus MTF values were obtained. Results Bench Badal image testing and MTF measurements showed that PanOptix has a near focus at a distance of 42 cm and an additional intermediate focus at a distance of about 60 cm. The near focus for ReSTOR +3.0 D is at 45 cm. PanOptix and ReSTOR +3.0 D have comparable photopic distances and near MTF values. Additionally, PanOptix provided a substantial continuous range of vision from distance to intermediate and to near compared with ReSTOR +3.0 D. The halo propensity for PanOptix was slightly higher than that for ReSTOR +3.0 D. Conclusion Laboratory-based in vitro simulations showed that PanOptix trifocal IOL has comparable resolution and image quality performance in distance and near foci compared with ReSTOR +3.0 D IOL. PanOptix showed better resolution and image quality performance at the intermediate focus than ReSTOR +3.0 D IOL. PMID:27330273

  14. Clinical evaluation of two multifocal intraocular lens implantation patterns

    PubMed Central

    Lin, Hao-Tian; Chen, Wei-Rong; Ding, Zhao-Feng; Chen, Wan; Wu, Chang-Rui

    2012-01-01

    AIM To evaluate the visual outcomes and patient satisfaction of two multifocal intraocular lens implantation patterns, with the decision between the two patterns being guided by the patients' choice of visual zones that best suited their lifestyle, or lifestyle zones. METHODS This is a prospective non-randomized comparative study. The lifestyle zones of 32 consecutive age-related cataract patients (64 eyes) were investigated individually to guide the surgical decision between two multifocal intraocular lens implantation patterns. The first group (MIX) received a combined implantation of a ReZoom NXG1 lens in the dominant eye and a Tecnis ZM900 lens in the other eye. The second group (MATCH) received bilateral ReZoom NXG1 lenses. One year postoperatively, the patients were assessed for binocular uncorrected visual acuity, reading visual acuity, reading speed and depth of focus under different luminance and were surveyed for visual disturbances, satisfaction and complete spectacle independence. RESULTS According to the determination of lifestyle zones, 18 and 14 patients were included in the MIX and MATCH groups, respectively. One year postoperatively, each of the patients exhibited positive visual outcomes and lifestyle satisfaction, although there were still some differences between the two groups. Generally, patients in the MATCH group had better distance visual acuity than those in the MIX group. In contrast, patients in the MIX group had better near visual acuity, better reading acuity and better reading speed than those in the MATCH group. Between the two groups, there was no clear difference in intermediate visual acuity, and the depths of focus between the two groups were approximately equal. The results of the mean NEI-RQL-42 questionnaire score, overall satisfaction, and complete spectacle independence did not differ between the two groups. CONCLUSION Different multifocal intraocular lenses implantation patterns can have differing advantages and

  15. UV solid state laser ablation of intraocular lenses

    NASA Astrophysics Data System (ADS)

    Apostolopoulos, A.; Lagiou, D. P.; Evangelatos, Ch.; Spyratou, E.; Bacharis, C.; Makropoulou, M.; Serafetinides, A. A.

    2013-06-01

    Commercially available intraocular lenses (IOLs) are manufactured from silicone and acrylic, both rigid (e.g. PMMA) and foldable (hydrophobic or hydrophilic acrylic biomaterials), behaving different mechanical and optical properties. Recently, the use of apodizing technology to design new diffractive-refractive multifocals improved the refractive outcome of these intraocular lenses, providing good distant and near vision. There is also a major ongoing effort to refine laser refractive surgery to correct other defects besides conventional refractive errors. Using phakic IOLs to treat high myopia potentially provides better predictability and optical quality than corneal-based refractive surgery. The aim of this work was to investigate the effect of laser ablation on IOL surface shaping, by drilling circular arrays of holes, with a homemade motorized rotation stage, and scattered holes on the polymer surface. In material science, the most popular lasers used for polymer machining are the UV lasers, and, therefore, we tried in this work the 3rd and the 5th harmonic of a Q-switched Nd:YAG laser (λ=355 nm and λ=213 nm respectively). The morphology of the ablated IOL surface was examined with a scanning electron microscope (SEM, Fei - Innova Nanoscope) at various laser parameters. Quantitative measurements were performed with a contact profilometer (Dektak-150), in which a mechanical stylus scanned across the surface of gold-coated IOLs (after SEM imaging) to measure variations in surface height and, finally, the ablation rates were also mathematically simulated for depicting the possible laser ablation mechanism(s). The experimental results and the theoretical modelling of UV laser interaction with polymeric IOLs are discussed in relation with the physical (optical, mechanical and thermal) properties of the material, in addition to laser radiation parameters (laser energy fluence, number of pulses). The qualitative aspects of laser ablation at λ=213 nm reveal a

  16. The Safety, Pharmacokinetics, and Efficacy of Intraocular Celecoxib

    PubMed Central

    Kim, Stephen J.; Toma, Hassanain; Shah, Rohan; Kompella, Uday B.; Vooturi, Sunil K.; Sheng, Jinsong

    2014-01-01

    Purpose. To determine safety, pharmacokinetics, and anti-inflammatory effects of intraocular celecoxib. Methods. The right eye of animals was injected with 1.5, 3, or 6 mg celecoxib prepared in dimethyl sulfoxide (DMSO). Left eyes served as controls and received 0.1 mL DMSO. Electroretinograms (ERG) were obtained at baseline and at 1, 4, and 12 weeks, and eyes were enucleated afterward for histopathologic analysis. For pharmacokinetics, 3 mg celecoxib was injected, and vitreous and retina/choroid drug levels were then analyzed at specific time points. For efficacy, 1 μg lipopolysaccharide was injected to induce inflammation; the right eye was then injected with 3 mg celecoxib (six eyes) or 2 mg triamcinolone acetonide (six eyes) and the left eye with saline. Twenty-four hours later, aqueous fluid was removed, and total leukocyte concentration and prostaglandin E2 (PGE2) concentration were determined. Results. Histologic and ERG studies demonstrated no signs of retinal or optic nerve toxicity. After a single 3-mg injection, vitreous (0.06 μg/mL) and retina/choroid (132.31 μg/g) celecoxib concentrations at 8 weeks exceeded median inhibitory concentration. Treatment with celecoxib and triamcinolone significantly reduced total leukocyte count by 40% (P = 0.02) and 31% (P = 0.01), respectively. Reduction in PGE2 levels paralleled reduction in leukocyte counts (P < 0.05). There was no increase in intraocular pressure, but cataract formation was observed at higher concentrations. Conclusions. Intraocular injection of celecoxib appeared to be nontoxic and demonstrated excellent penetration into the retina/choroid and sustained drug levels out to 8 weeks. Celecoxib demonstrated potent anti-inflammatory effects, but there was an association with cataract formation at higher doses. PMID:24458149

  17. ["Physical eyes" for evaluating various intraocular lenses for monocular and binocular use].

    PubMed

    Jacobi, K W; Reiner, J

    1993-12-01

    We developed a "physical eye system" to evaluate visual impression after physical implantation of monofocal and multifocal intraocular lenses (IOLs). The system is constructed as two identical astronomical telescopes. The objectives imitate the cornea and behind this cornea the IOL is inserted. The image quality represents exactly the quality of the intraocular lens. PMID:8145490

  18. Extensive facial and orbital infantile hemangiomas associated with high intraocular pressure.

    PubMed

    Shatriah, Ismail; Norazizah, Mohd-Amin; Wan-Hitam, Wan-Hazabbah; Wong, Abd-Rahim; Yunus, Rohaizan; Leo, Seo-Wei

    2013-01-01

    High intraocular pressure is a rare ophthalmic condition associated with infantile hemangiomas that involves the orbit, eyelid, or both. Here, we describe a patient with extensive facial and orbital infantile hemangiomas associated with high intraocular pressure in the affected eye. The prompt management of this challenging condition is essential. PMID:22329437

  19. Intraocular implants for the surgical correction of presbyopia

    NASA Astrophysics Data System (ADS)

    Parel, Jean-Marie A.; Rol, Pascal O.; Tahi, Hassan; Manns, Fabrice; Milne, Peter J.; Hamaoui, Marie; Ho, Arthur; Holden, Brien

    2000-06-01

    The surgical techniques proposed to restore accommodation past the onset of presbyopia can be categorized in two classes, those based of scleral expansion and those based on intraocular lens implantation and lens capsule refilling. This paper describes and discusses the different techniques and summarizes the results of clinical and experimental animal trials. Restoration of accommodation has been demonstrated by at least two different teams in non-human senile primates using modifications of the lens capsule refilling technique originally described by Julius Kessler in the late fifties. The advent of recent advances in microsurgery, devices, and injectable polymers are very promising and human clinical trials may soon be envisaged.

  20. Delayed accumulation of lens material behind the foldable intraocular lens.

    PubMed

    Bhattacharjee, Harsha; Bhattacharjee, Kasturi; Bhattacharjee, Pankaj

    2007-01-01

    Foldable acrylic intraocular lenses (IOLs) are known to reduce posterior capsule opacification by preventing migration of lens epithelial cells with its square edge design and its property of tackiness. Studies have reported a mean adhesiveness to posterior capsule more than three times higher for certain acrylic foldable IOLs than polymethyl methacrylate IOLs. The authors would like to report two cases where the force of tackiness was compensated, thereby presenting with delayed accumulation of lens material in the capsular bags behind the IOL with temporary loss of vision. PMID:17951912

  1. Delayed accumulation of lens material behind the foldable intraocular lens

    PubMed Central

    Bhattacharjee, Kasturi; Bhattacharjee, Pankaj

    2007-01-01

    Foldable acrylic intraocular lenses (IOLs) are known to reduce posterior capsule opacification by preventing migration of lens epithelial cells with its square edge design and its property of tackiness. Studies have reported a mean adhesiveness to posterior capsule more than three times higher for certain acrylic foldable IOLs than polymethyl methacrylate IOLs. The authors would like to report two cases where the force of tackiness was compensated, thereby presenting with delayed accumulation of lens material in the capsular bags behind the IOL with temporary loss of vision. PMID:17951912

  2. Effect of transscleral neodymium: YAG cyclophotocoagulation on intraocular lenses

    SciTech Connect

    Blomquist, P.H.; Gross, R.L.; Koch, D.D. )

    1990-03-01

    A neodymium: YAG laser operating in the thermal mode was used to irradiate isolated intraocular lenses (IOLs) and to perform transscleral cyclophotocoagulation on pseudophakic autopsy eyes to investigate the potential damage to IOL haptics such irradiation may cause. In the isolated IOLs, 70 mJ of energy deformed and partially melted both polymethylmethacrylate (PMMA) and polypropylene haptics. One of the capsular-fixated PC-IOL haptics in an autopsy eye partially melted when irradiated with the maximum energy level (8.8 J), with the aiming beam focused 1 mm posterior to the limbus and maximal posterior focus offset.

  3. Cataract and keratoconus: minimizing complications in intraocular lens calculations.

    PubMed

    Bozorg, Sara; Pineda, Roberto

    2014-01-01

    Patients with both cataract and keratoconus present unique challenges for the surgeon. Accurate keratometry (K) and axial length (AL) readings may be impossible, and uncertainty is introduced when estimating the corneal power for intraocular lens (IOL) selection. Different options on how to choose an IOL and how to manage irregular astigmatism of a keratoconic patient with cataract have been proposed and are reviewed. The stage of keratoconus and the history of the patient are both critical in determining the strategy used in treatment of cataracts. PMID:25325863

  4. In situ tumbling of the AcrySof intraocular lens.

    PubMed

    Rao, S K; Leung, A T; Lam, D S; Padmanabhan, P

    2000-02-01

    The small incision through which foldable acrylic intraocular lenses (IOLs) are implanted does not allow easy explantation of the lens in the event of intraoperative complications. Reversal of the IOL optic during insertion, although rare, can predispose to postoperative complications such as pupillary capture of the IOL, capsule bag distension syndrome, and refractive problems. Explanting the IOL can damage it, the cataract wound, or both. We describe a technique of in situ tumbling of the AcrySof IOL to correct reversed-optic implantation that preserves the integrity of the IOL and anterior segment structures. PMID:10683784

  5. Comparison of Artisan iris-claw intraocular lens implantation and posterior chamber intraocular lens sulcus fixation for aphakic eyes

    PubMed Central

    Teng, He; Zhang, Hong

    2014-01-01

    AIM To compare the efficacy and complications of Artisan iris-claw intraocular lens (IOL) implantation and posterior chamber IOL sulcus fixation for the treatment of aphakic eyes without capsular support after vitrectomy. METHODS A prospective study of 45 cases was conducted. Forty-five eyes without sufficient lens capsule support following pars plana vitrectomy (PPV) combined lens extraction were divided into two groups. Group A: 25 eyes received Artisan iris-claw IOL implantation. Group B: 20 eyes received posterior chamber IOL sulcus fixation. The corrected distance visual acuity (CDVA) and intraocular pressure (IOP), corneal endothelial cell loss rate, surgical time and complications were compared between the two groups. Pigment changes of trabecular meshwork and anterior chamber depths were measured at each time point in Artisan group. RESULTS The mean surgical time of Artisan group was significantly shorter (P<0.05). No statistically significant difference in endothelial cell loss rate was noted between two groups at any time point (P>0.05). CDVA of Artian group was better than that of the sulcus fixation group 1d after surgery (P<0.05) and there was no statistically significant difference 1 and 3mo after surgery (P>0.05). Mean IOP showed no significant differences between groups before and after surgery. The postoperative complications of Artisan group were anterior uveitis, iris depigmentation, pupillary distortion and spontaneous lens dislocation. The complications of sulcus fixation group include choroidal detachment, intraocular haemorrhage, tilt of IOL optic part and retinal detachment. CONCLUSION Secondary Artisan IOL implantation can be performed less invasively and in a shorter surgical time period with earlier visual recovery after surgery compared to transscleral suturing fixation of an IOL. This technique is an effective and safe procedure. It is a promising option for the treatment of aphakic eyes without capsular support after vitrectomy. PMID

  6. Intra-ocular pressure normalization technique and equipment

    NASA Technical Reports Server (NTRS)

    Mcgannon, W. J. (Inventor)

    1980-01-01

    A method and apparatus for safely reducing abnormally high intraocular pressure in an eye during a predetermined time interval is presented. This allows maintenance of normal intraocular pressure during glaucoma surgery. According to the invention, a pressure regulator of the spring biased diaphragm type is provided with additional bias by a column of liquid. The height of the column of liquid is selected such that the pressure at a hypodermic needle connected to the output of the pressure regulator is equal to the measured pressure of the eye. The hypodermic needle can then be safely inserted into the anterior chamber of the eye. Liquid is then bled out of the column to reduce the bias on the diaphragm of the pressure regulator and, consequently, the output pressure of the regulator. This lowering pressure of the regulator also occurs in the eye by means of a small second bleed path provided between the pressure regulator and the hypodermic needle. Alternately, a second hypodermic needle may be inserted into the eye to provide a controlled leak off path for excessive pressure and clouded fluid from the anterior chamber.

  7. Prevention of intraocular pressure rise following intravitreal injection.

    PubMed Central

    Morlet, N; Young, S H

    1993-01-01

    The intraocular pressure change produced by an intravitreal injection of ganciclovir, 2 mg in 0.1 ml, was studied in patients with cytomegalovirus retinitis. Using a Tono-pen XL to measure the intraocular pressure (IOP) of four patients (six eyes) we found the mean pressure immediately following injection was 44.5 mm Hg. Measurements taken on separate occasions after a 30 mm Hg decompression of the eye for 15 minutes before the injection showed a mean IOP of only 20.6 mm Hg after the injection. Mercury bag decompression of the eye significantly reduced the rise in IOP following intravitreal injection (difference in the mean IOP rise = 26.4 mm Hg, df = 54, t = 7.67, p < 0.001). Without ocular decompression before injection, all patients complained of temporary loss of vision, and reflux of the injection solution was frequently observed. Use of ocular decompression also reduced the discomfort of the injection. Throughout the full course of treatment by this means there were no adverse effects on the visual acuity. This technique is recommended to those performing intravitreal injections. Images PMID:8218055

  8. Standardized methods for assessing the imaging quality of intraocular lenses

    NASA Astrophysics Data System (ADS)

    Norrby, N. E. Sverker

    1995-11-01

    The relative merits of three standardized methods for assessing the imaging quality of intraocular lenses are discussed based on theoretical modulation-transfer-function calculations. The standards are ANSI Z80.7 1984 from the American National Standards Institute, now superseded by ANSI Z80.7 1994, and the proposed ISO 11979-2 from the International Organization for Standardization. They entail different test 60% resolution efficiency in air, 70% resolutionefficiency in aqueous humor, and 0.43 modulation at 100 line pairs/mm in a model eye. The ISO working group found that the latter corresponds to 60% resolution efficiency in air in a ring test among eight laboratories on a sample of 39 poly(methyl) methacrylate lenses and four silicone lenses spanning the power (in aqueous humor) range of 10-30 D. In both ANSI Z80.7 1994 and ISO 11979-2, a 60% resolution efficiency in air remains an optional approval limit. It is concluded that the ISO configuration is preferred, because it puts the intraocular lens into the context of the optics of the eye. Note that the ISO standard is tentative and is currently being voted on.

  9. Standardized methods for assessing the imaging quality of intraocular lenses.

    PubMed

    Norrby, N E

    1995-11-01

    The relative merits of three standardized methods for assessing the imaging quality of intraocular lenses are discussed based on theoretical modulation-transfer-function calculations. The standards are ANSI Z80.7 1984 from the American National Standards Institute, now superseded by ANSI Z80.7 1994, and the proposed ISO 11979-2 from the International Organization for Standardization. They entail different test configurations and approval limits, respectively: 60% resolution efficiency in air, 70% resolution efficiency in aqueous humor, and 0.43 modulation at 100 line pairs/mm in a model eye. The ISO working group found that the latter corresponds to 60% resolution efficiency in air in a ring test among eight laboratories on a sample of 39 poly(methyl) methacrylate lenses and four silicone lenses spanning the power (in aqueous humor) range of 10-30 D. In both ANSI Z80.7 1994 and ISO 11979-2, a 60% resolution efficiency in air remains an optional approval limit. It is concluded that the ISO configuration is preferred, because it puts the intraocular lens into the context of the optics of the eye. Note that the ISO standard is tentative and is currently being voted on. PMID:21060604

  10. Posterior Iris Fixated Intraocular Lens for Pediatric Traumatic Cataract

    PubMed Central

    Kavitha, V.; Balasubramanian, Preethi; Heralgi, Mallikarjun M.

    2016-01-01

    Purpose: To evaluate the postoperative visual outcomes and complications of posterior iris fixated intraocular lens (IFIOL) implantation for pediatric traumatic cataract. Methods: A retrospective clinical audit was performed of all the pediatric traumatic cataract patients who underwent lens removal and iris fixated lens implantation due to inadequate capsular support with or without corneal tear repair between January 2009 and December 2013. Data were collected and analyzed on the preoperative and postoperative visual outcomes and complications. Results: Twenty-five children (25 eyes; 21 males and 4 females) were enrolled with the mean age of 11 ± 4.0 years. There were 72% of eyes that underwent primary cataract removal with IFIOL implantation. Twenty-eight percent of eyes underwent corneal tear repair prior to intraocular lens (IOL) implantation. Preoperative best corrected visual acuity (BCVA) was hand motion in 32% eyes, counting fingers in 24%, and perception of light in 44%. Postoperative BCVA of 0-0.2 logarithm of minimum angle of resolution was reported in the 64% of eyes. One eye developed secondary glaucoma, one eye underwent re-enclavation, and none developed retinal complications. Conclusion: Posterior IFIOL implantation resulted in an improved visual outcome, low incidence of postoperative complications, and is a good alternative to other IOL, in the cases of pediatric traumatic cataract without adequate capsular support. PMID:27162456

  11. Case of Primary Intraocular Lymphoma with Extraocular Extension

    PubMed Central

    Kuro, Maki; Matsuyama, Kayako; Matsuoka, Masato; Kosaki, Ryo; Shikata, Nobuaki; Nishimura, Tetsuya; Takahashi, Kanji

    2015-01-01

    Purpose To describe a case of primary intraocular lymphoma (PIOL) with an extension through the sclera that was confirmed to be part of the PIOL by histopathological examinations. Case An 89-year-old woman was referred to a local clinic with a 1-year history of persistent blurred vision in her left eye. After 2 years without aggressive treatments, she had a marked reduction of vision and pain in her left eye. The clinical diagnosis was panophthalmitis, and the eye was enucleated and submitted for histopathological study. Results Light microscope examination showed that atypical lymphocytic cells had infiltrated into both the intraocular and extraocular areas. The anterior chamber angle was blocked by infiltrating tumor cells, which were also detected around the optic nerve. The tumor cells destroyed Bruch's membrane and infiltrated around the perineural and perivascular areas within the sclera. Immunohistochemistry showed that the tumor cells were positive for B-lymphocyte surface antigen (CD20), B-cell antigen receptor complex-associated protein alpha chain (CD79-alpha), and had a high positive rate for anti-Ki-67 antibody. Conclusion The finding in our case indicates that early diagnosis and treatment are important for eyes with PIOL because the tumor can spread and penetrate the sclera and invade extraocular tissues. PMID:27171820

  12. Purification and Characterization of an Endophytic Fungal Proteinase That Is Abundantly Expressed in the Infected Host Grass.

    PubMed Central

    Lindstrom, J. T.; Belanger, F. C.

    1994-01-01

    A novel Acremonium typhinum proteinase that is expressed during endophytic infection of the grass Poa ampla Merr. was purified from endophyte-infected leaf sheath tissue. It is a thiol-containing serine alkaline endoproteinase with bound carbohydrate. In the infected host tissue, this proteinase is an abundant protein localized within fungal membrane vesicles and in the plant and/or fungal cell walls. This proteinase was not expressed constitutively during fungus culture. Rather, its expression appeared to be induced by nutrient depletion. Expression of an antigenically similar proteinase was detected in five other endophyte-infected Poa species. The regulated expression of the proteinase in culture and its abundance in infected plant tissue suggest that its expression may be involved in the symbiotic interaction of the plant and the fungus. PMID:12232300

  13. An examination of the hypothesis that intraocular pressure elevation episodes can have prognostic significance in glaucoma suspects

    PubMed Central

    McMonnies, Charles

    2014-01-01

    The efficacy of intraocular pressure reduction in retarding the progression of glaucoma has been demonstrated. This review examines the potential for prognostic advantage for glaucoma suspects in reducing their optic nerve head exposure to elevated intraocular pressure associated with activities which have been shown to elevate intraocular pressure. In this observational study, patients examined at the Centre for Eye Health (University of New South Wales) with a diagnosis of glaucoma suspect were surveyed to determine their histories for participation in activities which are known to elevate intraocular pressure. The evidence regarding the pathological significance of these sources of elevation in susceptible patients was examined. Apart from the universality of sleep-related intraocular pressure elevations, the histories from 183 confirmed glaucoma suspects indicate a wide range and variation in frequency of participation in other intraocular pressure elevating activities. A reduction in exposure to elevated intraocular pressure may improve the prognosis for glaucoma suspects. Additional patient specific assessment of the results of this screening could provide an indication of the degree (frequency, intensity level and duration) of exposure to elevated intraocular pressure. Such information may provide the basis for improving a patient's prognosis by helping them to identify opportunities to reduce such exposure to elevated intraocular pressure. Any benefit of reduction of such exposure appears likely to be greater if activities which elevate intraocular pressure are of long duration, occur frequently, occur over a long period of time, and/or involve high levels of intraocular pressure elevation. PMID:25199440

  14. An examination of the hypothesis that intraocular pressure elevation episodes can have prognostic significance in glaucoma suspects.

    PubMed

    McMonnies, Charles

    2015-01-01

    The efficacy of intraocular pressure reduction in retarding the progression of glaucoma has been demonstrated. This review examines the potential for prognostic advantage for glaucoma suspects in reducing their optic nerve head exposure to elevated intraocular pressure associated with activities which have been shown to elevate intraocular pressure. In this observational study, patients examined at the Centre for Eye Health (University of New South Wales) with a diagnosis of glaucoma suspect were surveyed to determine their histories for participation in activities which are known to elevate intraocular pressure. The evidence regarding the pathological significance of these sources of elevation in susceptible patients was examined. Apart from the universality of sleep-related intraocular pressure elevations, the histories from 183 confirmed glaucoma suspects indicate a wide range and variation in frequency of participation in other intraocular pressure elevating activities. A reduction in exposure to elevated intraocular pressure may improve the prognosis for glaucoma suspects. Additional patient specific assessment of the results of this screening could provide an indication of the degree (frequency, intensity level and duration) of exposure to elevated intraocular pressure. Such information may provide the basis for improving a patient's prognosis by helping them to identify opportunities to reduce such exposure to elevated intraocular pressure. Any benefit of reduction of such exposure appears likely to be greater if activities which elevate intraocular pressure are of long duration, occur frequently, occur over a long period of time, and/or involve high levels of intraocular pressure elevation. PMID:25199440

  15. Survey of Intraocular Antibiotics Prophylaxis Practice after Open Globe Injury in China

    PubMed Central

    Tan, Junlian; Yang, Yao; Yuan, Zhaohui; Lin, Xiaofeng

    2016-01-01

    Purpose To elucidate the Chinese practice of intraocular antibiotics administration for prophylaxis after open globe injury. Methods A cross-sectional questionnaire survey was performed online by scanning a Quickmark (QR) code with smartphones at the 20th Chinese National Conference of Ocular Trauma in November 2014. Results A total of 153 (30.6%) of all participators at the conference responded. Of the respondents, 20.9% were routinely administered with prophylactic intraocular injection of antibiotics at the conclusion of the primary eye repair, and 56.9% were used only in cases with high risk of endophthalmitis development. The intraocular route of delivery was mainly included with intracameral injection (47.9%) and intravitreal injection (42.0%). Cephalosporins (53.8%) and vancomycin (42.0%) were the main choices of antibiotic agents, followed by fluoroquinolones (24.3%), and aminoglycosides (13.4%). Only 21.9% preferred a combination of two or more two drugs routinely. In addition, significantly more respondents from the referral eye hospital (92.7%) replied using intraocular antibiotics injection for prophylaxis compared to those respondents from the primary hospital (69.4%) (p = 0.001, Fisher’s exact test). Conclusions Intraocular antibiotics injection for post-traumatic endophthalmitis prophylaxis is widely used in China. However, the choice of antibiotic agents and the intraocular route of delivery vary. A well-designed clinical trial is needed to establish a standardized protocol of intraocular antibiotics administration for post-traumatic endophthalmitis prophylaxis. PMID:27275777

  16. Professor Peter Choyce: an early pioneer of intraocular lenses and corneal/refractive surgery.

    PubMed

    Pandey, Suresh K; Apple, David J

    2005-06-01

    Professor Peter Choyce, FRCS, DOMS, MS, was one of the pioneers of intraocular lens implant surgery. He developed an interest in artificial lens implantation following cataract surgery, a procedure that was widely criticized by the ophthalmic establishment in the UK, Europe, North America and other countries. Owing to the opposition to the intraocular lenses, Peter Choyce together with Sir Harold Ridley co-founded the International Intraocular Implant Club in 1966, which was responsible for the gradual acceptance of artificial lens implantation. Peter Choyce developed several models of intraocular lens, but did not patent the majority of them. The Choyce Mark IX, manufactured by Rayner Intraocular Lenses, became the first US Food and Drug Administration-approved intraocular lens in 1981. A review of Peter Choyce's record confirms a significant number of original innovations in the field of anterior segment surgery, including many procedures taken for granted today, but not associated with his name. These include early work on both kerato- and intraocular lens-refractive procedures, keratoprosthesis, pioneering paediatric implant procedures and others. Unfortunately his tenacious adherence to anterior chamber lens technology, while in general clinically sound, caused many to question his influence and hence he remained poorly understood even until after his death. He passed away on 8 August 2001 after a long fight with colon cancer. In this article, we provide evidence and elaborate Peter Choyce's accomplishments, which places him as one of the most innovative ophthalmologist in his surgical field in the twentieth century. PMID:15932534

  17. Optical quality of toric intraocular lens implantation in cataract surgery

    PubMed Central

    Xiao, Xian-Wen; Hao, Jing; Zhang, Hong; Tian, Fang

    2015-01-01

    AIM To analyze the optical quality after implantation of toric intraocular lens with optical quality analysis system. METHODS Fifty-two eyes of forty-four patients with regular corneal astigmatism of at least 1.00 D underwent implantation of AcrySof toric intraocular lens, including T3 group 19 eyes, T4 group 18 eyes, T5 group 10 eyes, T6 group 5 eyes. Main outcomes evaluated at 3mo of follow-up, included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), residual refractive cylinder and intraocular lens (IOL) axis rotation. Objective optical quality were measured using optical quality analysis system (OQAS II®, Visiometrics, Spain), included the cutoff frequency of modulation transfer function (MTFcutoff), objective scattering index (OSI), Strehl ratio, optical quality analysis system value (OV) 100%, OV 20% and OV 9% [the optical quality analysis system (OQAS) values at contrasts of 100%, 20%, and 9%]. RESULTS At 3mo postoperative, the mean UDVA and CDVA was 0.18±0.11 and 0.07±0.08 logMAR; the mean residual refractive cylinder was 0.50±0.29 D; the mean toric IOL axis rotation was 3.62±1.76 degrees, the mean MTFcutoff, OSI, Strehl ratio, OV 100%, OV 20% and OV 9% were 22.862±5.584, 1.80±0.84, 0.155±0.038, 0.76±0.18, 0.77±0.19 and 0.78±0.21. The values of UDVA, CDVA, IOL axis rotation, MTFcutoff, OSI, Strehl ratio, OV100%, OV20% and OV9% depending on the power of the cylinder of the implantation were not significantly different (P>0.05), except the residual refractive cylinder (P<0.05). CONCLUSION The optical quality analysis system was useful for characterizing the optical quality of AcrySof toric IOL implantation. Implantation of an AcrySof toric IOL is an effective and safe method to correct corneal astigmatism during cataract surgery. PMID:25709910

  18. Tritan colour contrast sensitivity function in refractive multifocal intraocular lenses

    PubMed Central

    Pieh, S.; Hanselmayer, G.; Lackner, B.; Marvan, P.; Grechenig, A.; Weghaupt, H.; Vass, C.; Skorpik, C.

    2001-01-01

    AIMS—To compare tritan colour contrast sensitivity (CCS), without and with glare, in patients with refractive multifocal intraocular lenses (IOLs) and with monofocal intraocular lenses.
METHODS—Tritan CCS was determined (Moorfields Vision System, CH Electronics) in 15 eyes (14 patients, 75.7 (±6.6) years) with a refractive multifocal IOL (Allergan SA 40N) and in 11 eyes (10 patients, 73.7 (±6.4) years) with a monofocal IOL (Allergan SI 40 NB). Measurements were made monocularly under mesopic conditions at a distance of 2 metres from the monitor with best distance refraction plus 0.5 D at 0.5, 1, 3, 6, 11.4, and 22.8 cycles per degree (cpd). The test was then repeated for the multifocal IOLs, adding minus 2.5 D to the best distance refraction to force the patient to use the near focus. Both lenses were also investigated under glare conditions with the same set-up and using the brightness acuity tester (BAT).
RESULTS—The tritan CCS function without glare in multifocal lenses through the distance focus was nearly identical to that through the near focus. The following statistically significant differences were measured: the CCS function without glare for the multifocal lens was worse at 0.5 cpd and 1.0 cpd than that of the monofocal lens. In CCS testing of the multifocal group with glare at 6 cpd, the results through the distance focus were better than the results through the near focus. For the CCS function with glare, the values for the distance focus in the multifocal lens were worse than the values for the monofocal lens at 0.5 cpd and 1 cpd. In CCS testing with glare through the near focus and CCS testing through the monofocal lens, the monofocal lens performed better at 0.5 cpd, 1 cpd, 3 cpd, and 6 cpd.
CONCLUSION—Refractive multifocal intraocular lenses influence tritan CCS function compared to monofocal lenses.

 PMID:11423455

  19. Associations with Intraocular Pressure in a Large Cohort

    PubMed Central

    Chan, Michelle P.Y.; Grossi, Carlota M.; Khawaja, Anthony P.; Yip, Jennifer L.Y.; Khaw, Kay-Tee; Patel, Praveen J.; Khaw, Peng T.; Morgan, James E.; Vernon, Stephen A.; Foster, Paul J.

    2016-01-01

    Purpose To describe the associations of physical and demographic factors with Goldmann-correlated intraocular pressure (IOPg) and corneal-compensated intraocular pressure (IOPcc) in a British cohort. Design Cross-sectional study within the UK Biobank, a large-scale multisite cohort study in the United Kingdom. Participants We included 110 573 participants from the UK Biobank with intraocular pressure (IOP) measurements available. Their mean age was 57 years (range, 40–69 years); 54% were women, and 90% were white. Methods Participants had 1 IOP measurement made on each eye using the Ocular Response Analyzer noncontact tonometer. Linear regression models were used to assess the associations of IOP with physical and demographic factors. Main Outcome Measures The IOPg and IOPcc. Results The mean IOPg was 15.72 mmHg (95% confidence interval [CI], 15.70–15.74 mmHg), and the mean IOPcc was 15.95 mmHg (15.92–15.97 mmHg). After adjusting for covariates, IOPg and IOPcc were both significantly associated with older age, male sex, higher systolic blood pressure (SBP), faster heart rate, greater myopia, self-reported glaucoma, and colder season (all P < 0.001). The strongest determinants of both IOPg and IOPcc were SBP (partial R2: IOPg 2.30%, IOPcc 2.26%), followed by refractive error (IOPg 0.60%, IOPcc 1.04%). The following variables had different directions of association with IOPg and IOPcc: height (−0.77 mmHg/m IOPg; 1.03 mmHg/m IOPcc), smoking (0.19 mmHg IOPg, −0.35 mmHg IOPcc), self-reported diabetes (0.41 mmHg IOPg, −0.05 mmHg IOPcc), and black ethnicity (−0.80 mmHg IOPg, 0.77 mmHg IOPcc). This suggests that height, smoking, diabetes, and ethnicity are related to corneal biomechanical properties. The increase in both IOPg and IOPcc with age was greatest among those of mixed ethnicities, followed by blacks and whites. The same set of covariates explained 7.4% of the variability of IOPcc but only 5.3% of the variability of IOPg. Conclusions This analysis

  20. Change in Intraocular Pressure During Point-of-Care Ultrasound

    PubMed Central

    Berg, Cameron; Doniger, Stephanie J.; Zaia, Brita; Williams, Sarah R.

    2015-01-01

    Introduction Point-of-care ocular ultrasound (US) is a valuable tool for the evaluation of traumatic ocular injuries. Conventionally, any maneuver that may increase intraocular pressure (IOP) is relatively contraindicated in the setting of globe rupture. Some authors have cautioned against the use of US in these scenarios because of a theoretical concern that an US examination may cause or exacerbate the extrusion of intraocular contents. This study set out to investigate whether ocular US affects IOP. The secondary objective was to validate the intraocular pressure measurements obtained with the Diaton® as compared with standard applanation techniques (the Tono-Pen®). Methods We enrolled a convenience sample of healthy adult volunteers. We obtained the baseline IOP for each patient by using a transpalpebral tonometer. Ocular US was then performed on each subject using a high-frequency linear array transducer, and a second IOP was obtained during the US examination. A third IOP measurement was obtained following the completion of the US examination. To validate transpalpebral measurement, a subset of subjects also underwent traditional transcorneal applanation tonometry prior to the US examination as a baseline measurement. In a subset of 10 patients, we obtained baseline pre-ultrasound IOP measurements with the Diaton® and Tono-Pen®, and then compared them. Results The study included 40 subjects. IOP values during ocular US examination were slightly greater than baseline (average +1.8mmHg, p=0.01). Post-US examination IOP values were not significantly different than baseline (average −0.15mmHg, p=0.42). In a subset of 10 subjects, IOP values were not significantly different between transpalpebral and transcorneal tonometry (average +0.03mmHg, p=0.07). Conclusion In healthy volunteer subjects, point-of-care ocular US causes a small and transient increase in IOP. We also showed no difference between the Diaton® and Tono-Pen® methods of IOP measurement

  1. [To guard against mistakes in selection of intraocular lenses].

    PubMed

    He, Shou-zhi

    2008-04-01

    Development of different kinds of new intraocular lenses (IOL) provide more selections to meet various clinical requirements, which may plays an active role in making cataract surgery more perfectible. But there are many misunderstandings about how to select the proper IOL. For example, "the expensive one is the best one", "new product is absolutely perfect", and so on. Some surgeons prefer more practice and ignore the summary of the experiences. Someone unilaterally exaggerates some special function of IOL When selecting the IOL, it is a common challenge for us to fully consider the patients needs, and properly manage the relationship between the basic need and special need, and to avoid fanaticism, and provide the best benefits to the patients. PMID:18844010

  2. Safety evaluation of BSS plus in pediatric intraocular surgery.

    PubMed

    Burke, M J; Parks, M M; Calhoun, J H; Diamond, J G; deFaller, J M

    1981-01-01

    An open-label study was conducted to determine the safety of a new intraocular irrigating solution, BSS Plus, when used during pediatric ophthalmic surgery. BBS Plus is a modified glutathione-bicarbonate-Ringer's solution which contains the necessary ions, buffers, and substrates for maintenance of normal cellular metabolism, function, and structural integrity when used as a perfusate during ophthalmic surgical procedures. At three centers, 30 patients undergoing lens aspiration or anterior segment reconstruction using vitrectomy instrumentation were enrolled in this study. Transient postoperative increases in intracellular pressure and internal or external ocular inflammatory signs were seen which were consistent with the trauma produced by the surgical procedure. The solution was judged to be safe when used in these surgical indications. PMID:7264851

  3. Experimental intraocular malignancy: the effect of intracameral perfusion.

    PubMed Central

    Wong, V G; Green, W R; Liu, Y P; Marsden, E R

    1979-01-01

    Transplantable Brown-Pearce carcinoma was adapted successfully in the rabbit anterior chamber. Regression of tumor growth was attained on tri-weekly perfusion of the AC with 10 micromolar of methotrexate. Tumor cyclic nucleotide phosphodiesterase (PDE) and protein activator were found to be markedly depressed during the course of chemotherapy and the PDE cAMP/cGMP ratio was similarly altered. Corroborative light and electron-microscopic studies showed specific alterations of intracellular organelles in relation to MTX and tumor cell death. These findings suggest that metabolic pathways of cyclic nucleotides are important biochemical modulators of neoplastic cells. The method of intraocular perfusion precludes systemic toxic effects and avoids compromising the animals' immunocompetence. Images FIGURE 3 A FIGURE 3 B FIGURE 4 A FIGURE 4 B PMID:232585

  4. Simulation of eye deformation in the measurement of intraocular pressure

    NASA Astrophysics Data System (ADS)

    Khusainov, R. R.; Tsibul'Skii, V. R.; Yakushev, V. L.

    2011-02-01

    The procedure of measuring the intraocular pressure by an optical analyzer is numerically simulated. The cornea and the sclera are considered as axisymmetrically deformable shells of revolution with fixed boundaries; the space between these shells is filled with incompressible fluid. Nonlinear shell theory is used to describe the stressed and strained state of the cornea and sclera. The optical system is calculated from the viewpoint of the geometrical optics. Dependences between the pressure in the air jet and the area of the surface reflecting the light into a photodetector are obtained. The shapes of the regions on the cornea surface are found from which the reflected light falls on the photodetector. First, the light is reflected from the center of the cornea, but then, as the cornea deforms, the light is reflected from its periphery. The numerical results make it possible to better interpret the measurement data.

  5. Ectopic intraocular lens: an unusual complication of cataract surgery.

    PubMed

    Shah, Mehul A; Shah, Shreya A; Aggarwal, Parul M

    2014-06-01

    We wish to report an unusual complication of intraocular lens (IOL) insertion following uneventful phacoemulsification. After successful phacoemulsification surgery, a hydrophobic acrylic IOL was loaded in the injector for insertion into the capsular bag. During insertion, the IOL inadvertently extended into the corneal stromal lamella. The complication was recognized at a late stage, and the foldable acrylic lens was retrieved and reinserted correctly in the bag. The anterior chamber was made viscoelastically taut and was maintained in this state for 10 min, followed by a routine viscoelastic wash and air bubble injection. Cornea was slightly edematous with stromal haze, and the corneal thickness was 908 μm. At the 1-month follow-up visit, the patient's vision was 20/40, the stromal haze had subsided, the corneal thickness was 572 μm, and the patient was comfortable. Though it was unknown complication, following proper management patient recovered satisfactorily. PMID:25005208

  6. Use of the Toric Intraocular Lens for Keratoconus Treatment

    PubMed Central

    Zvornicanin, Jasmin; Cabric, Emir; Jusufovic, Vahid; Musanovic, Zlatko; Zvornicanin, Edita

    2014-01-01

    A 50 year old man presented to Eye clinic University clinical centre Tuzla with bilateral visual impairment. Clinical examination revealed low visual acuity and keratoconus in both eyes, white cataract in right eye and diabetic retinopathy in left eye. Ultrasonography examination was normal. The patient underwent Trypan blue capsule staining, phacoemulsification and implantation of intraocular lens Alcon AcrySof SN60T9 16 D spherical and 6.0 D cylinder power. Phacoemulsification went uneventful and early postoperative recovery was successful. Visual acuity improved to 0,8 and fundus examination revealed background diabetic retinopathy. Postoperative follow up two years after surgery showed no signs of keratoconus progression and visual acuity maintained the same. PMID:24825942

  7. Bionic intraocular lens with variable focus and integrated structure

    NASA Astrophysics Data System (ADS)

    Liang, Dan; Wang, Xuan-Yin; Du, Jia-Wei; Xiang, Ke

    2015-10-01

    This paper proposes a bionic accommodating intraocular lens (IOL) for ophthalmic surgery. The designed lens has a solid-liquid mixed integrated structure, which mainly consists of a support ring, elastic membrane, rigid lens, and optical liquid. The lens focus can be adjusted through the deformation of the lens front surface when compressed. The integrated structure of the IOL is presented, as well as a detailed description of the lens materials and fabrication process. Images under different radial pressures are captured, and the lens deformation process, accommodating range, density, and optical property are analyzed. The designed lens achieves a 14.6 D accommodating range under a radial pressure of 51.4 mN and a 0.24 mm alteration of the lens outer radius. The deformation property of the lens matches well with the characteristic of the eye and shows the potential to help patients fully recover their vision accommodation ability after the cataract surgery.

  8. [Intraocular metallic crystalline lens for correction of aphakia].

    PubMed

    Aderikhin, I V; Golubchik, V L; Gorban', A I; Kolbin, M N

    1995-01-01

    Technological characteristics of a new in principle intraocular lens (IOL) consisting of a leukosaphire lens and elastic tantalum haptics are presented. The advantages of metallic crystal IOLs are validated: complete chemical and biological inertness, longevity, high transparency, and easy implantation in the capsular sac. Surgical recommendations are offered and highly positive results of clinical trials analyzed (more than 600 implantations followed up for up to 4 years). Metallic crystal IOLs for intracapsular correction of aphakia developed at the S. I. Vavilov All-Russian Research Center and St. Petersburg Division of the Moscow Research and Technological Complex "Ocular Microsurgery" and manufactured by the IOL Joint Stock Company are recommended for wide clinical use. PMID:7483205

  9. Shape optimization of an accommodative intra-ocular lens

    NASA Astrophysics Data System (ADS)

    Jouve, François; Hanna, Khalil

    2005-03-01

    Cataract surgery consists in replacing the clouded or opacified crystalline lens by an Intra-Ocular Lens (IOL) having the same mean dioptrical power. Clear vision is then achieved at a given distance and glasses are needed in many situations. A new kind of IOL, potentially accommodative, is proposed. Its design is based on the deep understanding of the accommodation mechanism and on the mathematical modeling and the numerical simulation of the IOL's comportment in vivo. A preliminary version of this IOL is now commercialized by the company HumanOptics under the name '1CU'. In a second phase, shape optimization techniques equipped with strong mechanical and physiological constraints, are used to enhance the IOL performance and build a new design. To cite this article: F. Jouve, K. Hanna, C. R. Mecanique 333 (2005).

  10. Intraocular electro-optic lens with ciliary muscle controlled accommodation.

    PubMed

    Doornaert, Dries; Glorieux, Christ; De Gersem, Herbert; Puers, Robert; Spileers, Werner; Blanckaert, Johan

    2013-01-01

    In this paper a concept is proposed of an intraocular lens implant with electro-optic accommodation of a variable-focus hybrid liquid-crystal-based lens. The dioptric strength of the lens is electronically controlled by a signal that is derived from the change of inductance of a sensing coil due to a marker implanted in the nearby contracting or decontracting ciliary muscle. Analytical, numerical and experimental results are reported on the dependency of the frequency of a Colpitts oscillator circuit on the location of a nearby conductive marker. A concept is also reported on the use as an electro-optic lens of a device based on a liquid crystal in planar alignment, which is held between a flat and a curved window coated with optically transparent and electrically conductive layers. PMID:24110406

  11. Survey of the optical quality of intraocular lens implants.

    PubMed

    Grossman, L W; Igel, D A; Faaland, R W

    1991-03-01

    Intraocular lenses (IOLs) from 15 U.S. firms were tested for conformance to the requirements of the American National Standards Institute Z80.7 standard for IOLs. A total of 162 IOLs were tested for resolution, astigmatism, and accuracy of labeled power. Average resolving power was 78% of the diffraction limit, much better than the ANSI minimum requirement which is typically equivalent to 30% of the diffraction limit. This suggests that the ANSI Z80.7 requirement could be significantly tightened with little effect on current production practices. Only one IOL exhibited astigmatism in excess of 0.25 diopter. Differences between measured and labeled power in excess of 0.50 diopter were found in 22 lenses, indicating that accuracy of refractive power may be the most commonly missed optical requirement of the standard. PMID:2040974

  12. Intraocular Lens Fragmentation Using Femtosecond Laser: An In Vitro Study

    PubMed Central

    Bala, Chandra; Shi, Jeffrey; Meades, Kerrie

    2015-01-01

    Purpose: To transect intraocular lenses (IOLs) using a femtosecond laser in cadaveric human eyes. To determine the optimal in vitro settings, to detect and characterize gasses or particles generated during this process. Methods: A femtosecond laser was used to transect hydrophobic and hydrophilic acrylic lenses. The settings required to enable easy separation of the lens fragment were determined. The gasses and particles generated were analysed using gas chromatography mass spectrometer (GC-MS) and total organic carbon analyzer (TOC), respectively. Results: In vitro the IOL fragments easily separated at the lowest commercially available energy setting of 1 μJ, 8-μm spot, and 2-μm line separation. No particles were detected in the 0.5- to 900-μm range. No significant gasses or other organic breakdown by products were detected at this setting. At much higher energy levels 12 μJ (4 × 6 μm spot and line separation) significant pyrolytic products were detected, which could be harmful to the eye. In cadaveric explanted IOL capsule complex the laser pulses could be applied through the capsule to the IOL and successfully fragment the IOL. Conclusion: IOL transection is feasible with femtosecond lasers. Further in vivo animal studies are required to confirm safety. Translational Relevance: In clinical practice there are a number of large intraocular lenses that can be difficult to explant. This in-vitro study examines the possibility of transecting the lasers quickly using femtosecond lasers. If in-vivo studies are successful, then this innovation could help ophthalmic surgeons in IOL explantation. PMID:26101721

  13. Cost-Effectiveness of Proton Beam Therapy for Intraocular Melanoma

    PubMed Central

    Moriarty, James P.; Borah, Bijan J.; Foote, Robert L.; Pulido, Jose S.; Shah, Nilay D.

    2015-01-01

    Purpose Proton beam therapy is a commonly accepted treatment for intraocular melanomas, but the literature is lacking in descriptions of patient preferences of clinical outcomes and economic impact. In addition, no economic evaluations have been published regarding the incremental cost-effectiveness of proton beam therapy compared with enucleation or plaque brachytherapy, typical alternative treatments. We, therefore, conducted a cost-utility analysis of these three approaches for the treatment of intraocular melanomas. Materials and Methods A Markov model was constructed. Model parameters were identified from the published literature and publicly available data sources. Cost-effectiveness of each treatment was calculated in 2011 US Dollars per quality-adjusted life-year. Incremental cost-effectiveness ratios were calculated assuming enucleation as reference. One-way sensitivity analyses were conducted on all model parameters. A decision threshold of $50,000/quality-adjusted life-year was used to determine cost-effectiveness. Results Enucleation had the lowest costs and quality-adjusted life-years, and plaque brachytherapy had the highest costs and quality-adjusted life-years. Compared with enucleation, the base-case incremental cost-effectiveness ratios for plaque brachytherapy and proton beam therapy were $77,500/quality-adjusted life-year and $106,100/quality-adjusted life-year, respectively. Results were highly sensitive to multiple parameters. All three treatments were considered optimal, and even dominant, depending on the values used for sensitive parameters. Conclusion Base-case analysis results suggest enucleation to be optimal. However, the optimal choice was not robust to sensitivity analyses and, depending on the assumption, both plaque brachytherapy and proton beam therapy could be considered cost-effective. Future clinical studies should focus on generating further evidence with the greatest parameter uncertainty to inform future cost

  14. Effect of hemodialysis on intraocular lens power calculation.

    PubMed

    Çalışkan, Sinan; Çelikay, Osman; Biçer, Tolga; Aylı, Mehmet Deniz; Gürdal, Canan

    2016-03-01

    Background To evaluate changes in ocular biometric parameters after hemodialysis (HD) in patients with end-stage renal disease (ESRD). Methods Forty eyes of 40 patients undergoing HD were included in this cross-sectional study. Keratometry (K) readings, white-to-white (WTW) distance, central corneal thickness (CCT), anterior chamber depth (ACD), pupil diameter, lens thickness (LT), axial length (AL), and intraocular lens (IOL) power calculation were measured with Lenstar LS 900 (Haag Streit AG, Koeniz, Switzerland) before and after hemodialysis. Intraocular pressure (IOP) was measured with a non-contact tonometer (Tonopachy NT-530P, Nidek Co., LTD, Tokyo, Japan). Main outcomes were changes in biometric parameters after HD. Reliability of the measurements (intraclass correlation coefficients (ICCs)) and the effect size (Cohen's d) were also calculated. Results Mean difference in AL before and after HD was -0.041 ± 0.022 mm with ICCs > 0.90 (p < 0.001 and Cohen's d = 0.06). Pupil diameter was also significantly different before (4.28 ± 0.81 mm) and after (4.44 ± 0.79 mm) HD with ICCs > 0.90 (p = 0.041 and Cohen's d = 0.20). Hemodialysis had no significant effect on K readings, WTW distance, CCT, ACD, LT, or IOP. Conclusion Axial length and pupil diameter increase after HD with small effect size, while HD does not significantly affect IOL power calculations. PMID:26707804

  15. Design of a Test Bench for Intraocular Lens Optical Characterization

    NASA Astrophysics Data System (ADS)

    Alba-Bueno, Francisco; Vega, Fidel; Millán, María S.

    2011-01-01

    The crystalline lens is the responsible for focusing at different distances (accommodation) in the human eye. This organ grows throughout life increasing in size and rigidity. Moreover, due this growth it loses transparency through life, and becomes gradually opacified causing what is known as cataracts. Cataract is the most common cause of visual loss in the world. At present, this visual loss is recoverable by surgery in which the opacified lens is destroyed (phacoemulsification) and replaced by the implantation of an intraocular lens (IOL). If the IOL implanted is mono-focal the patient loses its natural capacity of accommodation, and as a consequence they would depend on an external optic correction to focus at different distances. In order to avoid this dependency, multifocal IOLs designs have been developed. The multi-focality can be achieved by using either, a refractive surface with different radii of curvature (refractive IOLs) or incorporating a diffractive surface (diffractive IOLs). To analyze the optical quality of IOLs it is necessary to test them in an optical bench that agrees with the ISO119679-2 1999 standard (Ophthalmic implants. Intraocular lenses. Part 2. Optical Properties and Test Methods). In addition to analyze the IOLs according to the ISO standard, we have designed an optical bench that allows us to simulate the conditions of a real human eye. To do that, we will use artificial corneas with different amounts of optical aberrations and several illumination sources with different spectral distributions. Moreover, the design of the test bench includes the possibility of testing the IOLs under off-axis conditions as well as in the presence of decentration and/or tilt. Finally, the optical imaging quality of the IOLs is assessed by using common metrics like the Modulation Transfer Function (MTF), the Point Spread Function (PSF) and/or the Strehl ratio (SR), or via registration of the IOL's wavefront with a Hartmann-Shack sensor and its

  16. Argon laser trabeculoplasty as a means of decreasing intraocular pressure from ''normal'' levels in glaucomatous eyes

    SciTech Connect

    Sharpe, E.D.; Simmons, R.J.

    1985-06-15

    The authors conducted a retrospective study of 67 patients (85 eyes) with severe glaucoma to determine whether argon laser trabeculoplasty could reduce intraocular pressures below the ''normal'' range. All patients had initial intraocular pressures of less than or equal to 19 mm Hg. Success was defined as a decrease in intraocular pressure of at least 20%, no increase in medications, stable visual field, and no subsequent glaucoma surgery. After an average follow-up period of 30 months, treatment was successful in 31 cases. One half of the failures occurred by six months and 11 failures (30%) occurred after 12 months. Sixteen patients were able to decrease their medications. Two patients achieved intraocular pressures between 6 and 9 mm Hg and 20 between 10 and 12 mm Hg.

  17. [An instrument for projecting visual perception by monofocal and bifocal intraocular lenses].

    PubMed

    Reiner, J

    1992-01-01

    With the aid of a simple optical system similar to an astronomical telescope, images of spectacle lenses, contact lenses and intraocular lenses can be projected in front of, onto or into the eye. These optical images function like real lenses and enable their performance to be evaluated. In the case of intraocular lenses, visual perception through monofocal or bifocal lenses and teledioptric systems can be reproduced. PMID:1583844

  18. Transcorneal extrusion of anterior chamber intraocular lenses. A report of three cases.

    PubMed

    McKnight, G T; Richards, S C; Apple, D J; Stanko, M L; O'Morchoe, D J; Solomon, K D

    1987-12-01

    We examined three cases of transcorneal extrusion of anterior chamber intraocular lenses. In each case a preexisting condition (rheumatoid arthritis, glaucoma, and herpes zoster ophthalmicus, respectively) contributed to corneal necrosis and subsequent extrusion of the pseudophakos. The clinicopathologic correlations of this condition are discussed, as well as some causes of corneal decompensation associated with anterior chamber lenses. We emphasize the need for careful evaluation of patients who have preexisting disease before intraocular lens implantation. PMID:3318770

  19. [The progress of studies on intraocular lens implantation in cataract with high myopia].

    PubMed

    Liu, Xue; Wan, Xiuhua

    2015-07-01

    With development of the technology of cataract surgery, combined phacoemulsification and intraocular lens implantation in cataract with high myopia has been widely carried out in clinical treatment. Due to the particularity of high myopia, phacoemulsification in patients with cataract and high myopia is difficult and has recently received a lot of attentions. In this paper, preoperative examinations, the selection of intraocular lenses, surgery methods and surgical complications of cataract surgery in patients with cataract and high myopia are briefly reviewed. PMID:26310259

  20. The Increase of Intra-Abdominal Pressure Can Affect Intraocular Pressure

    PubMed Central

    Ece, Ilhan; Vatansev, Celalettin; Kucukkartallar, Tevfik; Tekin, Ahmet; Kartal, Adil; Okka, Mehmet

    2015-01-01

    Objective. This study aims to explore the usage of intraocular pressure measurements as the early indicator of the increase in intra-abdominal pressure. Methods. In this prospective study, 40 patients undergoing elective surgery were included. Patients were divided into four groups of 10 patients. The control group (Group C) was not subjected to laparoscopic intervention. Laparoscopic surgery was, respectively, performed with an intra-abdominal pressure of 9, 12, and 15 mmHg in Groups L (low), M (medium), and H (high pressure). Intraocular pressure was measured binocularly in each patient at three different times (before, during, and end of surgery) using a contact tonometer. Results. Patients' gender, age, body mass index (BMI), American Society of Anesthesiology (ASA) class, and operative times were not different among the groups. No complications occurred with either the surgery or measurement of intraocular pressure. Intubation was associated with a severe rise in IOP (P < 0.05). An increase in intraocular pressure was seen in groups M and H (P < 0.05). Conclusion. Intraocular pressure was increased in the groups with an intra-abdominal pressure of 12 mmHg or more. Measuring the intraocular pressure might be a useful method to estimate the intra-abdominal pressure. This trial is registered with NCT02319213. PMID:25648230

  1. A new device to noninvasively estimate the intraocular pressure produced during ocular compression

    PubMed Central

    Korenfeld, Michael S; Dueker, David K

    2016-01-01

    Purpose To describe a noninvasive instrument that estimates intraocular pressure during episodes of external globe compression and to demonstrate the accuracy and reliability of this device by comparing it to the intraocular pressures simultaneously and manometrically measured in cannulated eyes. Methods A thin fluid-filled bladder was constructed from flexible and inelastic plastic sheeting and was connected to a pressure transducer with high pressure tubing. The output of the pressure transducer was sent to an amplifier and recorded. This device was validated by measuring induced pressure in the fluid-filled bladder while digital pressure was applied to one surface, and the other surface was placed directly against a human cadaver eye or in vivo pig eye. The human cadaver and in vivo pig eyes were each cannulated to provide a manometric intraocular pressure control. Results The measurements obtained with the newly described device were within ~5% of simultaneously measured manometric intraocular pressures in both a human cadaver and in vivo pig eye model for a pressure range of ~15–100 mmHg. Conclusion This novel noninvasive device is useful for estimating the intraocular pressure transients induced during any form of external globe compression; this is a clinical setting where no other devices can be used to estimate intraocular pressure. PMID:26955260

  2. Comparison of dose calculation methods for brachytherapy of intraocular tumors

    SciTech Connect

    Rivard, Mark J.; Chiu-Tsao, Sou-Tung; Finger, Paul T.; Meigooni, Ali S.; Melhus, Christopher S.; Mourtada, Firas; Napolitano, Mary E.; Rogers, D. W. O.; Thomson, Rowan M.; Nath, Ravinder

    2011-01-15

    Purpose: To investigate dosimetric differences among several clinical treatment planning systems (TPS) and Monte Carlo (MC) codes for brachytherapy of intraocular tumors using {sup 125}I or {sup 103}Pd plaques, and to evaluate the impact on the prescription dose of the adoption of MC codes and certain versions of a TPS (Plaque Simulator with optional modules). Methods: Three clinical brachytherapy TPS capable of intraocular brachytherapy treatment planning and two MC codes were compared. The TPS investigated were Pinnacle v8.0dp1, BrachyVision v8.1, and Plaque Simulator v5.3.9, all of which use the AAPM TG-43 formalism in water. The Plaque Simulator software can also handle some correction factors from MC simulations. The MC codes used are MCNP5 v1.40 and BrachyDose/EGSnrc. Using these TPS and MC codes, three types of calculations were performed: homogeneous medium with point sources (for the TPS only, using the 1D TG-43 dose calculation formalism); homogeneous medium with line sources (TPS with 2D TG-43 dose calculation formalism and MC codes); and plaque heterogeneity-corrected line sources (Plaque Simulator with modified 2D TG-43 dose calculation formalism and MC codes). Comparisons were made of doses calculated at points-of-interest on the plaque central-axis and at off-axis points of clinical interest within a standardized model of the right eye. Results: For the homogeneous water medium case, agreement was within {approx}2% for the point- and line-source models when comparing between TPS and between TPS and MC codes, respectively. For the heterogeneous medium case, dose differences (as calculated using the MC codes and Plaque Simulator) differ by up to 37% on the central-axis in comparison to the homogeneous water calculations. A prescription dose of 85 Gy at 5 mm depth based on calculations in a homogeneous medium delivers 76 Gy and 67 Gy for specific {sup 125}I and {sup 103}Pd sources, respectively, when accounting for COMS-plaque heterogeneities. For off

  3. Comparison of dose calculation methods for brachytherapy of intraocular tumors

    PubMed Central

    Rivard, Mark J.; Chiu-Tsao, Sou-Tung; Finger, Paul T.; Meigooni, Ali S.; Melhus, Christopher S.; Mourtada, Firas; Napolitano, Mary E.; Rogers, D. W. O.; Thomson, Rowan M.; Nath, Ravinder

    2011-01-01

    Purpose: To investigate dosimetric differences among several clinical treatment planning systems (TPS) and Monte Carlo (MC) codes for brachytherapy of intraocular tumors using 125I or 103Pd plaques, and to evaluate the impact on the prescription dose of the adoption of MC codes and certain versions of a TPS (Plaque Simulator with optional modules). Methods: Three clinical brachytherapy TPS capable of intraocular brachytherapy treatment planning and two MC codes were compared. The TPS investigated were Pinnacle v8.0dp1, BrachyVision v8.1, and Plaque Simulator v5.3.9, all of which use the AAPM TG-43 formalism in water. The Plaque Simulator software can also handle some correction factors from MC simulations. The MC codes used are MCNP5 v1.40 and BrachyDose∕EGSnrc. Using these TPS and MC codes, three types of calculations were performed: homogeneous medium with point sources (for the TPS only, using the 1D TG-43 dose calculation formalism); homogeneous medium with line sources (TPS with 2D TG-43 dose calculation formalism and MC codes); and plaque heterogeneity-corrected line sources (Plaque Simulator with modified 2D TG-43 dose calculation formalism and MC codes). Comparisons were made of doses calculated at points-of-interest on the plaque central-axis and at off-axis points of clinical interest within a standardized model of the right eye. Results: For the homogeneous water medium case, agreement was within ∼2% for the point- and line-source models when comparing between TPS and between TPS and MC codes, respectively. For the heterogeneous medium case, dose differences (as calculated using the MC codes and Plaque Simulator) differ by up to 37% on the central-axis in comparison to the homogeneous water calculations. A prescription dose of 85 Gy at 5 mm depth based on calculations in a homogeneous medium delivers 76 Gy and 67 Gy for specific 125I and 103Pd sources, respectively, when accounting for COMS-plaque heterogeneities. For off-axis points

  4. Tumor vascularity and hematogenous metastasis in experimental murine intraocular melanoma.

    PubMed Central

    Grossniklaus, H E

    1998-01-01

    PURPOSE: The purpose of this study is to test the hypothesis that primary tumor vascularity in a murine model of intraocular melanoma positively correlates with the development and hematogenous spread of metastasis. METHODS: Forty 12-week-old C57BL6 mice were inoculated in either the anterior chamber (AC) or posterior compartment (PC) of 1 eye with 5 x 10(5) cells/microL of Queens tissue culture melanoma cells. The inoculated eye was enucleated at 2 weeks; the mice were sacrificed at 4 weeks postinoculation, and necropsies were performed. The enucleated eyes were examined for histologic and ultrastructural features, including relationship of tumor cells to tumor vascular channels, vascular pattern, and mean vascular density. RESULTS: Melanoma grew and was confined to the eye in 12 of 20 AC eyes and 10 of 20 PC eyes. Histologic and electron microscopic examination showed tumor invasion into vascular channels. Five of 12 AC tumors (42%) and 8 of 10 PC tumors (80%) metastasized. All of the AC tumors, but none of the PC tumors, that distantly metastasized also metastasized to ipsilateral cervical lymph nodes (P = .00535). There was no statistically significant difference of vascular pattern between the melanomas that did and did not metastasize to lungs in the PC group (P = .24), although there was a significant difference in the AC group (P = .02). Tumors with high-grade vascular patterns were more likely to metastasize than tumors with low-grade vascular patterns in the AC group. The mean vascular density positively correlated with the presence and number of metastases in both groups (P = .0000 and P < .001, respectively). There was no statistically significant difference of vascular pattern and mean vascular density for AC versus PC melanoma (P = .97). CONCLUSIONS: The rate of metastasis in this murine intraocular melanoma model positively correlates with primary tumor vascularity. The melanoma metastasizes via invasion of tumor vascular channels. AC melanoma also

  5. Mechanisms for vasopressin effects on intraocular pressure in anesthetized rats

    NASA Technical Reports Server (NTRS)

    Balaban, C. D.; Palm, D. E.; Shikher, V.; Searles, R. V.; Keil, L. C.; Severs, W. B.

    1997-01-01

    Continuous intracameral infusions of a balanced salt solution (0.175 microliter min-1) have been reported to raise intraocular pressure (IOP) in anesthetized rats. Palm et al. (1995) previously reported that this effect was attenuated significantly by inclusion of arginine-vasopressin (AVP, 10 ng 0.175 microliter-1) in the infusate. This study used experimental and computer simulation methods to investigate factors underlying these changes in IOP. First, constant intracameral infusions of artificial cerebrospinal fluid (aCSF) at different fixed rates (0.049-0.35 microliter min-1) were used to estimate the outflow resistance. Secondly, IOP responses were measured during an 2 hr intracameral infusion of either aCSF or AVP that was the sum of a small constant component (0.05 microliter min-1) and a larger periodic component (0.25 microliter min-1, cycling for 4 min on, then 4 min off); the mean infusion rate was 0.175 microliter min-1. As shown previously for 0.175 microliter min-1 constant infusions, the periodic aCSF infusion induced a significant rise in IOP that was attenuated by AVP administration. Complex demodulation analysis and the estimated gain parameter of a second order transfer function fit to the periodic responses indicated that outflow resistance increased significantly during the infusions in both aCSF and AVP groups, but that the indices of resistance did not differ significantly between aCSF and AVP infused eyes. This finding implies that changes in outflow resistance do not explain the difference in IOP responses to intracameral aCSF and AVP. The two responses differed significantly, though, in damping factors, such that the aCSF responses were considerably more underdamped than the AVP responses. It is hypothesized that aCSF-induced increase in IOP reflects both (1) a small component reflecting increased outflow resistance and (2) a larger non-resistive component. Since the non-resistive component is insensitive to pretreatment with acetazolamide

  6. Functionalised Polysiloxanes as Injectable, In Situ Curable Accommodating Intraocular Lenses

    PubMed Central

    Hao, Xiaojuan; Jeffery, Justine L.; Wilkie, John S.; Meijs, Gordon; Clayton, Anthony; Watling, Jason; Ho, Arthur; Fernandez, Viviana; Acosta, Carolina; Yamamoto, Hideo; Aly, Mohamed G. M.; Parel, Jean-Marie; Hughes, Timothy C.

    2010-01-01

    The aged eye’s ability to change focus (accommodation) may be restored by replacing the hardened natural lens with a soft gel. Functionalised polysiloxane macromonomers, designed for application as an injectable, in situ curable accommodating intraocular lens (A-IOL), were prepared via a two-step synthesis. Prepolymers were synthesised via ring opening polymerisation (ROP) of octamethylcyclotetrasiloxane (D4) and 2,4,6,8-tetramethylcyclotetrasiloxane (D4H) in toluene using trifluoromethanesulfonic acid (TfOH) as catalyst. Hexaethyldisiloxane (HEDS) was used as the end group to control the molecular weight of the prepolymers, which were then converted to macromonomers by hydrosilylation of the SiH groups with allyl methacrylate (AM) to introduce polymerisable groups. The resulting macromonomers had an injectable consistency and thus, were able to be injected into and refill the empty lens capsular bag. The macromonomers also contained a low ratio of polymerisable groups so that they may be cured on demand, in situ, under irradiation of blue light, in the presence of a photo-initiator, to form a soft polysiloxane gel (an intraocular lens) in the eye. The pre-cure viscosity and post-cure modulus of the polysiloxanes, which are crucial factors for an injectable, in situ curable A-IOL application, were controlled by adjusting the end group and D4H concentrations, respectively, in the ROP. The macromonomers were fully cured within 5 minutes under light irradiation, as shown by the rapid change in modulus monitored by photorheology. Ex vivo primate lens stretching experiments on an Ex Vivo Accommodation Simulator (EVAS) showed that the polysiloxane gel refilled lenses achieved over 60% of the accommodation amplitude of the natural lens. An in vivo biocompatibility study in rabbits using the lens refilling (Phaco-Ersatz) procedure demonstrated that the soft gels were biocompatible with the ocular tissue. The polysiloxane macromonomers meet the targeted optical and

  7. Intraocular pressure in very low birth weight preterm infants and its association with postconceptional age

    PubMed Central

    Lindenmeyer, Rodrigo L.; Farias, Lucas; Mendonça, Taís; Filho, João Borges Fortes; Procianoy, Renato S.; Silveira, Rita C.

    2012-01-01

    OBJECTIVE: To evaluate intraocular pressure in very low birth weight preterm infants and correlate it with postconceptional age. METHODS: The intraocular pressure in a prospective cohort of very low birth weight premature infants (defined as a birth weight ≤1,500 g and gestational age ≤32 weeks) admitted to Hospital de Clínicas de Porto Alegre, Brazil was evaluated weekly. The evaluated outcome was the variation in the intraocular pressure following changes in the postconceptional age (defined as the gestational age at birth plus the age in weeks at the time of examination) in the weeks following preterm birth. Mixed-effects models were used for the statistical analysis to determine the intraocular pressure variation according to postconceptional age, and means and 10th and 90th percentiles were calculated for the intraocular pressure values. RESULTS: Fifty preterm infants with a mean gestational age of 29.7±1.6 weeks and a mean birth weight of 1,127.7±222.7 g were evaluated. The mean intraocular pressure for the entire cohort considering both eyes was 14.9±4.5 mmHg, and 13.5% of all recorded intraocular pressure values were greater than 20 mmHg. The analysis revealed a mean reduction in the intraocular pressure of 0.29 mmHg for each increase in postconceptional age (p = 0.047; 95% CI: −0.58 to −0.0035). The mean intraocular pressure (P10–P90) decreased from 16.3 mmHg (10.52–22.16) at 26.3 weeks to 13.1 mmHg (7.28–18.92) at 37.6 weeks of postconceptional age. CONCLUSIONS: The mean intraocular pressure in very low birth weight preterm infants was 14.9±4.5 mmHg. This value decreased 0.29 mmHg per week as the postconceptional age increased. PMID:23184197

  8. Two remarkable events in the field of intraocular foreign body: (1) The reversal of siderosis bulbi. (2) The spontaneous extrusion of an intraocular copper foreign body.

    PubMed Central

    Welch, R B

    1975-01-01

    Two unusual events concerning intraocular foreign bodies are presented. The first patient had an occult or unsuspected intraocular foreign body. He showed iridoplegia with mydriasis, siderosis iridis, and an intraocular piece of iron lying posteriorly near the retina. The foreign body was removed and the patient regained normal iris color and pupillary activity. His vision remains 20/15 six years postoperatively dispite ensuing retinal detachment one year after removal of the foreign body. The second patient was a young boy injured by a blasting cap explosion. He lost one eye from the injury and had a piece of intraocular brass in his left eye. In spite of the development of chalcosis and a mature cataract the lens gradually shrank in the pupillary space permitting a clear aphakic area and 20/25 vision. The brass fragment migrated forward and inferiorly and was finally extruded under the conjunctiva five years later, where it was removed and chemically analyzed by x-ray diffraction. Images FIGURE 1 A FIGURE 1 B FIGURE 2 FIGURE 3 FIGURE 4 FIGURE 5 FIGURE 6 FIGURE 7 PMID:1108372

  9. Prognostic Factor Analysis of Intraocular Pressure with Neovascular Glaucoma.

    PubMed

    Nakano, Satoko; Nakamuro, Takako; Yokoyama, Katsuhiko; Kiyosaki, Kunihiro; Kubota, Toshiaki

    2016-01-01

    Purpose. To perform multivariate analysis for identifying independent predictors of elevated intraocular pressure (IOP) with neovascular glaucoma (NVG), including antivascular endothelial growth factor (VEGF) intravitreal injections. Methods. We retrospectively reviewed 142 NVG patients (181 eyes) with ischemic retinal diseases [proliferative diabetic retinopathy (PDR) in 134 eyes, retinal vein occlusion (RVO) in 29, and ocular ischemic syndrome in 18]. We analyzed age, gender, initial/final LogMAR VA, initial/final IOP, extent of iris and/or angle neovascularization, treatments, preexisting complications, concurrent medications, and follow-up duration. Results. The mean follow-up duration was 23.8 ± 18.8 months. At the final follow-up, 125 (72.3%) eyes had IOP ≤ 21 mmHg. NVG patients with RVO had a higher degree of angle closure and higher IOP. NVG with PDR had better IOP and LogMAR VA. Angle closure had the greatest impact on final IOP. Greater than 90% of patients treated with trabeculectomy with mitomycin C (LEC) had persistent declines in IOP (≤21 mmHg). Stand-alone and combination anti-VEGF therapies were not associated with improved long-term prognosis of IOP. Conclusions. Angle closure was found to have the greatest effect on NVG-IOP prognosis. When target IOP values are not obtained after adequate PRP with or without anti-VEGF, early LEC may improve the prognosis of IOP. PMID:27579175

  10. Prognostic Factor Analysis of Intraocular Pressure with Neovascular Glaucoma

    PubMed Central

    Nakamuro, Takako; Yokoyama, Katsuhiko; Kiyosaki, Kunihiro

    2016-01-01

    Purpose. To perform multivariate analysis for identifying independent predictors of elevated intraocular pressure (IOP) with neovascular glaucoma (NVG), including antivascular endothelial growth factor (VEGF) intravitreal injections. Methods. We retrospectively reviewed 142 NVG patients (181 eyes) with ischemic retinal diseases [proliferative diabetic retinopathy (PDR) in 134 eyes, retinal vein occlusion (RVO) in 29, and ocular ischemic syndrome in 18]. We analyzed age, gender, initial/final LogMAR VA, initial/final IOP, extent of iris and/or angle neovascularization, treatments, preexisting complications, concurrent medications, and follow-up duration. Results. The mean follow-up duration was 23.8 ± 18.8 months. At the final follow-up, 125 (72.3%) eyes had IOP ≤ 21 mmHg. NVG patients with RVO had a higher degree of angle closure and higher IOP. NVG with PDR had better IOP and LogMAR VA. Angle closure had the greatest impact on final IOP. Greater than 90% of patients treated with trabeculectomy with mitomycin C (LEC) had persistent declines in IOP (≤21 mmHg). Stand-alone and combination anti-VEGF therapies were not associated with improved long-term prognosis of IOP. Conclusions. Angle closure was found to have the greatest effect on NVG-IOP prognosis. When target IOP values are not obtained after adequate PRP with or without anti-VEGF, early LEC may improve the prognosis of IOP. PMID:27579175

  11. Foldable antibacterial acrylic intraocular lenses of high refractive index.

    PubMed

    Parra, F; Vázquez, B; Benito, L; Barcenilla, J; San Román, J

    2009-11-01

    Hydrophilic copolymers with high refractive index and bactericide properties based on quaternary ammonium salts monomers and methacrylates bearing benzothiazole moieties have been developed for application as foldable intraocular lenses. Composition of the systems was adjusted to get materials with optimized flexibility, wettability, and refractive properties. All the materials have been characterized in terms of optical properties, glass transition temperature, water content, and wettability. Water contact values oscillated between 37 and 15% and refractive index values in the wet state between 1.49 and 1.53, depending on composition. Glass transition temperature interval was 63-77 degrees C. Values of surface free energy of the solid ranged from 49 to 54 mN/m, characteristic of IOL hydrogel materials. Bactericide properties of the quaternary ammonium salts methacrylates were higher than that of the benzothiazole derivative, showing inhibition halos as high as 23-25 mm in antibiogram tests against S. epidermidis and P. aeruginosa , strains found in the ocular cavity and responsible for most postsurgical endolphthalmitis. Biocompatibility of the systems was evaluated in cell cultures using human fibroblasts. Cellular viability was higher than 90%, and close to 100% in many cases, for the extracts of selected formulations collected at different periods of time. PMID:19795830

  12. Intraocular Lymphoma:Update on Diagnosis and Management

    PubMed Central

    Chan, Chi-Chao; Wallace, Dana J.

    2007-01-01

    Background Primary intraocular lymphoma (PIOL) is a subset of primary central nervous system lymphoma (PCNSL) in which lymphoma cells initially invade the retina, vitreous, or optic nerve head, with or without concomitant CNS involvement. The incidence of this previously rare condition has increased dramatically. Given its nonspecific presentation and aggressive course, PIOL provides a diagnostic and therapeutic challenge. Methods We review the current strategies for diagnosis and treatment of PIOL and present our own experience with PIOL. Results Recent developments in the diagnosis of PIOL include immunohistochemistry, flow cytometry, cytokine evaluation, and molecular analysis. However, definitive diagnosis still requires harvesting of tissue for histopathology. Optimal treatment for PIOL remains unclear. Initial therapeutic regimens should include methotrexate-based chemotherapy and radiotherapy to the brain and eye. In addition, promising results have been seen with intravitreal methotrexate and autologous stem cell transplantation for recurrent and refractory disease. Conclusions Efforts to further determine the immunophenotype and molecular characteristics of PIOL will continue to assist in the diagnosis of PIOL. Future studies are required to determine the role of radiotherapy and optimal local and systemic chemotherapeutic regimens. PMID:15377987

  13. Diagnosis and management of primary intraocular lymphoma: an update

    PubMed Central

    Jahnke, Kristoph; Thiel, Eckhard; Abrey, Lauren E; Neuwelt, Edward A; Korfel, Agnieszka

    2007-01-01

    Despite recent advances in diagnosis and treatment, the prognosis of primary intraocular lymphoma (PIOL) remains poor, and the optimal treatment has yet to be defined. This review presents an overview of the current status of PIOL with a focus on recent advances in diagnosis and treatment. Recent studies show a decreasing time interval from symptom presentation to diagnosis, likely due to increased awareness of the disease and improved diagnostic tools. Advances in the pathologic characterization of PIOL have been made over the past years, and the development of PIOL animal models can offer the opportunity to study aspects of PIOL pathology, pathogenesis and treatment. Regarding treatment of PIOL, recent larger case series favor the use of systemic chemotherapy plus local ocular treatment as first-line management for patients with concomitant PIOL and PCNSL. For patients with isolated PIOL, the current trend focuses on local first-line treatment and early diagnosis of PIOL. Future studies are needed to confirm these trends. Future directions in the management of PIOL should include studies about pathogenesis, prognostic factors, and treatment optimization. In the future, monoclonal antibodies and radioimmunotherapy could prove useful for PIOL treatment. PMID:19668478

  14. Experiment design for through-focus testing of intraocular lenses

    NASA Astrophysics Data System (ADS)

    Millán, María. S.; Alba-Bueno, Francisco; Vega, Fidel

    2013-11-01

    Eye models to test intraocular lenses (IOLs) in an optical bench are commonly designed in agreement with the ISO 11979-2 and 11979-9 standard requirements. However, modifications to the ISO eye model have been proposed to test IOLs in conditions closer to real human eye. Wavefront analysis and aberration characterization, wavelength dependence, efficiency, off-axis performance and imaging degradation under certain amount of misalignment can thus be measured in vitro. The main parts of the system to test IOLs are: the illumination system and object test, the eye model including the IOL immersed in a wet cell and a microscope assembled to a sensor that magnifies and captures the aerial image of the object formed by the eye model. A problem concerning the simultaneous variation of defocus and magnification arises when using the microscope to capture out-of-focus images in a through-focus study. Using the eye model, we study the problem of implementing a through-focus measurement of the imaging quality of an IOL. We find a solution based on geometrical optics and compare it with other proposals reported in the literature. The effects on the measurement of the Modulation Transfer Function and the Point Spread Function are predicted. Experimental results are obtained and discussed.

  15. Effect of a tight necktie on intraocular pressure

    PubMed Central

    Teng, C; Gurses-Ozden, R; Liebmann, J M; Tello, C; Ritch, R

    2003-01-01

    Aim: To evaluate the effect of a tight necktie on intraocular pressure (IOP) measurement using Goldmann applanation tonometry. Methods: 40 eyes of 20 normal subjects and 20 open angle glaucoma patients (all male) were enrolled. IOP was measured with an open shirt collar, 3 minutes after placing a tight necktie, and 3 minutes after loosening it. All measurements were made by the same examiner. Results: Mean IOP in normal subjects increased by 2.6 (SD 3.9) mm Hg (p=0.008, paired t test; range −3 to +14 mm Hg) and in glaucoma patients by 1.0 (1.8) mm Hg (p=0.02, paired t test; range −2 to +4.5 mm Hg). In normal subjects, IOP in 12 eyes was increased by ⩾2 mm Hg and in seven eyes by ⩾4 mm Hg. In glaucoma patients, IOP in six eyes was increased by ⩾2 mm Hg and in two eyes by ⩾4 mm Hg. Conclusion: A tight necktie increases IOP in both normal subjects and glaucoma patients and could affect the diagnosis and management of glaucoma. PMID:12881330

  16. Impact factors on intraocular pressure measurements in healthy subjects

    PubMed Central

    Theelen, T; Meulendijks, C F M; Geurts, D E M; van Leeuwen, A; Voet, N B M; Deutman, A F

    2004-01-01

    Aim: To evaluate whether intraocular pressure (IOP) calculation by applanation tonometry is determined more essentially by the subject’s neck position or by neck constriction. Methods: 23 right eyes of 23 healthy subjects (12 male, 11 female) were included. IOP was measured by applanation tonometry with the TonoPen on sitting participants under four different conditions: with open collar upright (A) or with the head in the headrest of a slit lamp (B), with a tight necktie upright (C) or in slit lamp position (D). All measurements with neck constriction were performed 3 minutes after placing the necktie. Results: Mean IOP was 16.9 (SD 2.3) mm Hg (range 11–21 mm Hg) (A), 18.1 (SD 2.2) mm Hg (range 14–22 mm Hg) (B), 17.9 (SD 2.9) mm Hg (range 12–25 mm Hg) (C) and 18.7 (SD 2.7) mm Hg (range 13–24 mm Hg) (D). Mean IOP increased by 1.3 (SD 2.6) mm Hg (p = 0.028, paired t test, range +0.2 to +2.4 mm Hg) if subjects changed position from A to B. There was no statistically significant difference between measurements with or without neck constriction. Conclusion: Applanation tonometry may be inaccurate if performed in slit lamp position. In contrast, tight neckties do not significantly affect IOP evaluation in healthy subjects. PMID:15548801

  17. Aspheric Intraocular Lenses Implantation for Cataract Patients with Extreme Myopia

    PubMed Central

    Miao, Aizhu; Luo, Yi

    2014-01-01

    Objective. To evaluate the postoperative visual quality of cataract patients with extreme myopia after implantation of aspheric intraocular lenses (IOLs). Methods. Thirty-three eyes were enrolled in this prospectivestudy. Eighteen eyes with an axial length longer than 28 mm were included in the extreme myopia group, and the other 15 eyes were included in the nonextreme myopia group. Phacoemulsification and aspheric IOL implantation were performed. Six months after cataract surgery, best-corrected visual acuity (BCVA), contrast sensitivity, and wavefront aberrations were measured, and subjective visual quality was assessed. Results. The BCVA improved significantly after surgery for both groups, and patients in the nonextreme myopia group achieved better postoperative BCVA due to better retinal status of the eyes. The evaluation of contrast sensitivity without glare was the same in both groups, whereas patients in the nonextreme myopia group performed better at intermediate spatial frequencies under glare conditions. The two groups did not show a significant difference in high-order aberrations. With regard to subjective visual quality, the composite scores of both groups did not differ significantly. Conclusions. Aspheric IOLs provided good visual outcomes in cataract patients with extreme myopia. These patients should undergo careful evaluation to determine the maculopathy severity level before surgery. PMID:25006509

  18. Effect of four different intraocular lenses on posterior capsule opacification

    PubMed Central

    Duman, Rahmi; Karel, Fatih; Özyol, Pelin; Ateş, Can

    2015-01-01

    AIM To evaluate the impact of 4 different intraocular lenses (IOLs) on posterior capsule opacification (PCO) by comparing the neodymium: yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy rates. METHODS This retrospective study included 4970 eyes of 4013 cataract patients who underwent phacoemulsification and IOL implantation between January 2000 and January 2008 by the same surgeon at one clinic. Four different IOLs were assessed. The outcome parameter was the incidence of Nd:YAG laser posterior capsulotomies. RESULTS An Nd:YAG laser posterior capsulotomy was performed in 153 (3.07%) of the 4970 eyes. The mean follow-up time was 84mo for all of the IOL groups. The percentage of eyes developing PCO was significantly greater for the acrylic hydrophilic IOLs than for the hydrophobic IOLs, although eyes with acrylic hydrophilic IOLs did not require Nd:YAG laser capsulotomy as soon as eyes with acrylic hydrophobic IOLs. There was no difference between the long-term PCO rates when 1- and 3-piece acrylic hydrophobic IOLs were compared or when IOLs made of the same material but with different haptic angles were compared. CONCLUSION In this study, eyes with acrylic hydrophilic IOLs were more likely to develop PCO than those with acrylic hydrophobic IOLs. The lens design (1-piece versus 3-piece and varying haptic angles) did not affect the PCO rate. PMID:25709920

  19. Intraocular camera for retinal prostheses: Refractive and diffractive lens systems

    NASA Astrophysics Data System (ADS)

    Hauer, Michelle Christine

    The focus of this thesis is on the design and analysis of refractive, diffractive, and hybrid refractive/diffractive lens systems for a miniaturized camera that can be surgically implanted in the crystalline lens sac and is designed to work in conjunction with current and future generation retinal prostheses. The development of such an intraocular camera (IOC) would eliminate the need for an external head-mounted or eyeglass-mounted camera. Placing the camera inside the eye would allow subjects to use their natural eye movements for foveation (attention) instead of more cumbersome head tracking, would notably aid in personal navigation and mobility, and would also be significantly more psychologically appealing from the standpoint of personal appearances. The capability for accommodation with no moving parts or feedback control is incorporated by employing camera designs that exhibit nearly infinite depth of field. Such an ultracompact optical imaging system requires a unique combination of refractive and diffractive optical elements and relaxed system constraints derived from human psychophysics. This configuration necessitates an extremely compact, short focal-length lens system with an f-number close to unity. Initially, these constraints appear highly aggressive from an optical design perspective. However, after careful analysis of the unique imaging requirements of a camera intended to work in conjunction with the relatively low pixellation levels of a retinal microstimulator array, it becomes clear that such a design is not only feasible, but could possibly be implemented with a single lens system.

  20. Stem Cells in the Trabecular Meshwork for Regulating Intraocular Pressure.

    PubMed

    Yun, Hongmin; Zhou, Yi; Wills, Andrew; Du, Yiqin

    2016-06-01

    Intraocular pressure (IOP) is still the main treatment target for glaucoma. Outflow resistance mainly exists at the trabecular meshwork (TM) outflow pathway, which is responsible for IOP regulation. Changes of TM cellularity and TM extracellular matrix turnover may play important roles in IOP regulation. In this article, we review basic anatomy and physiology of the outflow pathway and TM stem cell characteristics regarding the location, isolation, identification and function. TM stem cells are localized at the insert region of the TM and are label-retaining in vivo. They can be isolated by side-population cell sorting, cloning culture, or sphere culture. TM stem cells are multipotent with the ability to home to the TM region and differentiate into TM cells in vivo. Other stem cell types, such as adipose-derived stem cells, mesenchymal stem cells and induced pluripotent stem cells have been discovered for TM cell differentiation and TM regeneration. We also review glaucomatous animal models, which are suitable to study stem cell-based therapies for TM regeneration. PMID:27183473

  1. Pharmacotherapy of intraocular pressure: part I. Parasympathomimetic, sympathomimetic and sympatholytics.

    PubMed

    Costagliola, Ciro; dell'Omo, Roberto; Romano, Mario R; Rinaldi, Michele; Zeppa, Lucia; Parmeggiani, Francesco

    2009-11-01

    Elevated intraocular pressure (IOP) has been recognized as the major risk factor for the development of glaucoma and a wide range of options are now available to reduce it: medical treatment, laser, filtering, or cyclodestructive surgery (alone or in combination). All these modalities act by decreasing eye pressure and, thereby, protecting the optic nerve head from a mechanic direct and/or vascular indirect insult. Topical medical therapy represents the first-choice treatment and, in most cases, it effectively controls IOP, avoiding the occurrence of further optic nerve damage. All medications lower IOP in two main ways: decreasing the production of aqueous humour or by increasing its outflow from the eye. Consequently, antiglaucoma drugs either suppress aqueous humour formation (beta-adrenergic antagonists, carbonic anhydrase inhibitors, and alpha-2-adrenergic agonists) or raise aqueous humour outflow throughout the conventional (e.g., pilocarpine) or uveoscleral (prostaglandin FP receptor agonists, and prostamides) route. In addition, fixed and unfixed combinations of antiglaucoma compounds have also been available for patients requiring more than one type of medication. This review, which is part one of two (please see Expert Opinion on Pharmacotherapy 10 (17)) briefly considers the characteristics of sympathomimetic, sympatholytics and parasympathomimetic commonly employed in the medical treatment of glaucoma, mainly the primary open-angle form, focusing the discussion on the clinical evidence supporting the use of these three classes of compound. PMID:19874249

  2. Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens

    PubMed Central

    Spierer, Oriel; O'Brien, Terrence P.

    2016-01-01

    A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL) which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful. PMID:27462251

  3. [Intraocular correction of aphakia in patients after kidney transplantation].

    PubMed

    Bocharov, V E; Ivanov, M N; Gantsovskiĭ, P I

    2004-01-01

    It was for the first time in the ophthalmologic practice that a possibility was demonstrated to ensure relatively high and stable functional results, in a significant number of patients with transplanted kidney (TK), related with different-type cataract extraction and with implantation of a variety of PMMA IOLs, i.e. model of B.A. Alexeev, "Storz" company models made from domestic and foreign-made PMMA and domestic-silicone models (P = 70). It was established that IOL implantation in patients with TK is possible in all cases provided the kidney transplant is compensated for and there are no foci of acute or chronic inflammation in the body. A minimal trauma caused by surgery and the suggested scheme of postoperative management (intramuscular injections of antibiotics and supplementary administration of solutions of poludan, naclof, catachrom and actovegin-gel made alongside with routine instillations) cuts the risk of infectious-and-inflammatory as well as of degenerative-and-dystrophic complications in patients with TK receiving the suppressor therapy. Clinical examinations denoted that the intraocular aphakia correction in patients with TK is a method of choice accelerating the medical and social rehabilitation in the discussed patients' category provided the therapeutic-and-diagnostic as well as preventive measures, as required by their status, are being taken. PMID:15384842

  4. Noninvasive Intraocular Pressure Measurements in Mice by Pneumotonometry

    PubMed Central

    Avila, Marcel Y.; Múnera, Alejandro; Guzmán, Arcadio; Do, Chi Wai; Wang, Zhao; Stone, Richard A.; Civan, Mortimer M.

    2005-01-01

    Purpose To develop a reliable, noninvasive, continuous, and easily implemented system for measuring intraocular pressure (IOP) in mice. Methods Pneumotonometry was adapted for measurement of mouse IOP. Measurements were compared with those obtained with the servo-null micropipette system (SNMS) and with direct anterior chamber cannulation. Heart rate was monitored by the precordial pulse, EKG, or tail pulse in anesthetized mice. The characteristic ocular hypotensive response to mannitol was assessed as an additional validation of the method. Results Measurements of IOP obtained using pneumotonometry agreed closely with values measured by SNMS or by direct cannulation. IOP oscillations were synchronous with the heart rate, with a coherence peak between them of ~2 Hz, equal to the pulse frequency. Hypertonic mannitol reduced IOP from 13.7 ± 0.9 mm Hg by 7.7 ± 0.7 mm Hg after 15 minutes. Conclusions Pneumotonometry is a reliable and noninvasive method for the measurement of IOP in mice and may permit comparisons of IOP to hemodynamic factors. This system is simpler and more adaptable for glaucoma research than previously reported methodologies for measuring IOP in mice. PMID:16123429

  5. Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens.

    PubMed

    Spierer, Oriel; O'Brien, Terrence P

    2016-01-01

    A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL) which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful. PMID:27462251

  6. Toward Automated Intraocular Laser Surgery Using a Handheld Micromanipulator

    PubMed Central

    Yang, Sungwook; MacLachlan, Robert A.; Riviere, Cameron N.

    2014-01-01

    This paper presents a technique for automated intraocular laser surgery using a handheld micromanipulator known as Micron. The novel handheld manipulator enables the automated scanning of a laser probe within a cylinder of 4 mm long and 4 mm in diameter. For the automation, the surface of the retina is reconstructed using a stereomicroscope, and then preplanned targets are placed on the surface. The laser probe is precisely located on the target via visual servoing of the aiming beam, while maintaining a specific distance above the surface. In addition, the system is capable of tracking the surface of the eye in order to compensate for any eye movement introduced during the operation. We compared the performance of the automated scanning using various control thresholds, in order to find the most effective threshold in terms of accuracy and speed. Given the selected threshold, we conducted the handheld operation above a fixed target surface. The average error and execution time are reduced by 63.6% and 28.5%, respectively, compared to the unaided trials. Finally, the automated laser photocoagulation was demonstrated also in an eye phantom, including compensation for the eye movement. PMID:25893135

  7. Micro-optical imaging concepts for an intraocular vision aid

    NASA Astrophysics Data System (ADS)

    Eix, Ilos; Stork, Wilhelm; Muller-Glaser, Klaus D.

    2004-03-01

    About 10 million people around the world are suffering from blindness, where the path of light is disturbed due to an opaque, irreversible damaged, and inoperable cornea. Although vision is not given to this group of population, the retina is still intact. To date, there is no artificial implant which is able to replace the natural cornea. The work presented here describes an approach to build and implant a micro-optical and microelectronic system to be used as an intraocular vision aid. By overcoming the disturbed light path, it yields to an improved visual acuity of the patient. The main aspect of this bio-mimetic system is to transfer information representing the patient's field of view to the retina. An image of the field of view is captured in real-time outside the eye. After employing data processing, it is wireless transferred to the implanted part of the vision aid. From there, the information emerging from a micro display is imaged to the retina via a micro-optical system. The limited display resolution available inside the eye and the limited dimensions of the eyeball build the constrains of the optical system. A combination of a spatial light modulator together with an imaging lens system realizes intelligent spatial information distribution schemes onto the retina. This ensures a high outcome of visual acuity in the central region of the retina. Various retinal acuities can be realized. The employment of in-vivo adjustment mechanisms of the focal plane is discussed.

  8. Non-continuous measurement of intraocular pressure in laboratory animals.

    PubMed

    Millar, J Cameron; Pang, Iok-Hou

    2015-12-01

    Glaucoma is a leading cause of blindness, which is treatable but currently incurable. Numerous animal models therefore have both been and continue to be utilized in the study of numerous aspects of this condition. One important facet associated with the use of such models is the ability to accurately and reproducibly measure (by cannulation) or estimate (by tonometry) intraocular pressure (IOP). At this juncture there are several different approaches to IOP measurement in different experimental animal species, and the list continues to grow. We feel therefore that a review of this subject matter is timely and should prove useful to others who wish to perform similar measurements. The general principles underlying various types of tonometric and non-tonometric techniques for non-continuous determination of IOP are considered. There follows discussion of specific details as to how these techniques are applied to experimental animal species involved in the research of this disease. Specific comments regarding anesthesia, circadian rhythm, and animal handling are also included, especially in the case of rodents. Brief consideration is also given to possible future developments. PMID:25933714

  9. Sulcus Fixation of Foldable Intraocular Lenses Guided by Ultrasound Biomicroscopy

    PubMed Central

    Gao, Shasha; Qin, Tingyu; Wang, Shengnan; Lu, Yong

    2015-01-01

    Background. To evaluate the clinical efficacy of suture fixation of foldable intraocular lens (IOL) in ciliary sulcus guided by ultrasound biomicroscopy (UBM). Methods. Thirty-five eyes of 32 cases needing suture fixation of foldable IOL in ciliary sulcus in our hospital were collected and divided into two groups: group A and group B. In group A, UBM was performed on 19 eyes of 17 cases before surgery to locate the projection position of ciliary sulcus in iris surface. In group B, the traditional sulcus fixation of IOL was performed on 16 eyes of 15 cases. The inserting position of needles, the haptics position of IOL and the IOL tilt, and decentration were observed by UBM examination 3 months after the surgery. Meanwhile, the vision and contrast sensitivity were analysed. Results. The differences in inserting position of the needle, the IOL tilt and decentration, the ratio of IOL haptics in sulcus, and uncorrected visual acuity were statistically significant (P < 0.05). The differences in best corrected visual acuity (BCVA) and contrast sensitivity were not statistically significant (P > 0.05). Conclusions. Sulcus fixation of foldable IOL aided by UBM can increase the accuracy of IOL haptics implanted into ciliary sulcus and reduce the IOL tilt and decentration. PMID:26413317

  10. Design and fabrication of a microstructured bifocal intraocular lens

    NASA Astrophysics Data System (ADS)

    Stork, Wilhelm; Wagner, Armin; Kreiner, Christine F.; Mueller-Glaser, Klaus-Dieter

    1999-06-01

    Intraocular lenses IOLs allow the vision restoration of cataract patients. However the ability of accommodation is lost after cataract surgery. Multifocal lenses show two or more foci with different refractive powers. Far and near objects can be at focus simultaneously. No additional spectacles are necessary. Bifocal lenses can be fabricated as multizone or as diffractive lenses. Diffractive multifocal lenses show in contrast to multi zone multifocal lenses no change of the brightness ratio for the far and near focus with change of the pupil diameter. Diffractive lenses show a saw tooth like microscopic shape with a geometrical height of the teeth in the order of microns. The lens was fabricated with a mold technique in a flexible silicone material. The molds have been lathed in metal with a ultra precision diamond lathe machine. For the test of the optical performance a MTF-measurement machine was constructed for multifocal lenses. With this machine the imaging quality and the intensity ratio of the two foci were measured. The optical quality of the lens turned out to be diffraction limited. At the University Hospital of Giessen, Germany a first clinical evaluation with 23 patients has been performed and proved for the high quality of the manufactured IOLs.

  11. Star testing: a novel evaluation of intraocular lens optical quality

    PubMed Central

    Mitchell, L; Molteno, A C B; Bevin, T H; Sanderson, G

    2006-01-01

    Background Despite the importance of optical quality of an intraocular lens (IOL) on visual outcomes following cataract surgery, objective data on their optical quality are not readily available, and manufacturing standards are industry regulated. The star test is a classic test of optical quality based on examination of the Airy disc and expanded diffraction rings of a point source of light, used mainly for telescope and microscope objectives. Methods A physical model eye cell allowed star testing of IOLs under conditions similar to the optical environment in which they operate. 18 IOLs were tested and results compared to actual images produced by these lenses in the model eye cell. Quantitative measures of star testing performance were developed. Results The optical performance of the IOLs varied, some performing very poorly. Most lenses (13/17) performed better in reverse orientation, while aberrations induced by the haptics of foldable IOLs were also detected. There was excellent correlation between actual images formed and star testing parameters. Conclusion Star testing IOLs was a novel biomedical application of a centuries old, inexpensive method. A concerning variation of optical quality was found, suggesting IOL optical performance data should be more readily available. Independent, authority mandated IOL optical quality standards should be developed, and results readily available to ophthalmologists. PMID:16622088

  12. Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo.

    PubMed

    Orssengo, G J; Pye, D C

    1999-05-01

    The purpose of this study was to determine the true intraocular pressure and modulus of elasticity of the human cornea in vivo. The cornea was modeled as a shell, and the equations for the deformations of a shell due to applanating and intraocular pressures were combined to model the behavior of the cornea during applanation tonometry. At certain corneal dimensions called the calibration dimensions, the applanating and intraocular pressures are considered to be equal. This relationship was used to determine the modulus of elasticity of the cornea and the relationship between the applanating and intraocular pressures. The true intraocular pressure (IOPT) was found to be related to Goldmann's applanating pressure (IOPG) as IOPT = IOPG/K, where K is a correction factor. For the calibration corneal thickness of 0.52 mm, the modulus of elasticity E in MPa of the human cornea was found to be related to the true intraocular pressure IOPT in mmHg as E = 0.02291OPT. The generalization of the Imbert-Fick law that takes into account the effect of corneal dimensions and stiffness was found to be given by IOPT = 73.5W/(K A), where W is the applanating weight in gf (gram force) and A is the applanated area in mm2. The calculated true intraocular pressure and modulus of elasticity were found to agree with published experimental results. The mathematical model developed may therefore be used to improve results from applanation tonometry and to estimate the mechanical property of the cornea in vivo. PMID:17883231

  13. Intraocular pressure and glaucoma: Is physical exercise beneficial or a risk?

    PubMed

    McMonnies, Charles William

    2016-01-01

    Intraocular pressure may become elevated with muscle exertion, changes in body position and increased respiratory volumes, especially when Valsalva manoeuver mechanisms are involved. All of these factors may be present during physical exercise, especially if hydration levels are increased. This review examines the evidence for intraocular pressure changes during and after physical exercise. Intraocular pressure elevation may result in a reduction in ocular perfusion pressure with the associated possibility of mechanical and/or ischaemic damage to the optic nerve head. A key consideration is the possibility that, rather than being beneficial for patients who are susceptible to glaucomatous pathology, any intraocular pressure elevation could be detrimental. Lower intraocular pressure after exercise may result from its elevation causing accelerated aqueous outflow during exercise. Also examined is the possibility that people who have lower frailty are more likely to exercise as well as less likely to have or develop glaucoma. Consequently, lower prevalence of glaucoma would be expected among people who exercise. The evidence base for this topic is deficient and would be greatly improved by the availability of tonometry assessment during dynamic exercise, more studies which control for hydration levels, and methods for assessing the potential general health benefits of exercise against any possibility of exacerbated glaucomatous pathology for individual patients who are susceptible to such changes. PMID:26794458

  14. Comparison Between Digital and Manual Marking for Toric Intraocular Lenses

    PubMed Central

    Elhofi, Abdel Hamid; Helaly, Hany Ahmed

    2015-01-01

    Abstract To compare the clinical outcome of digital and manual marking for toric intraocular lens (IOL) alignment. This is a prospective clinical study that included 60 eyes of 60 patients undergoing cataract surgery with coexisting corneal astigmatism more than 1 diopter (D). The eyes were randomly assigned to either digital image guidance using VERION digital marker (Alcon Laboratories, Ft. Worth, TX) or manual slitlamp-assisted preoperative marking using pendulum-attached marker. Tecnis toric IOL (Abbott Medical Optics, Inc, Santa Ana, CA) was implanted in all cases. The mean postoperative uncorrected distance visual acuity (UCDVA) for the digital-marking group was 0.12 + 0.12 logMAR, and for the manual-marking group was 0.18 + 0.14 logMAR (P = 0.104). The mean deviation from targeted induced astigmatism (TIA) for the first group was 0.10 + 0.08 D and for the second group was 0.20 + 0.14 D (P = 0.001). The mean postoperative toric IOL misalignment measured by the slitlamp was 2.4° + 1.96° for the first group and was 4.33° + 2.72° for the second group (P = 0.003). Accurate alignment of the toric IOL is important to achieve the desired astigmatism correction. VERION system has the advantage of preoperative planning and intraoperative digital guidance of the toric IOL alignment. The use of VERION system resulted in less postoperative deviation from TIA and showed less postoperative toric IOL misalignment than using manual-marking technique. PMID:26402830

  15. Driving time modulates accommodative response and intraocular pressure.

    PubMed

    Vera, Jesús; Diaz-Piedra, Carolina; Jiménez, Raimundo; Morales, José M; Catena, Andrés; Cardenas, David; Di Stasi, Leandro L

    2016-10-01

    Driving is a task mainly reliant on the visual system. Most of the time, while driving, our eyes are constantly focusing and refocusing between the road and the dashboard or near and far traffic. Thus, prolonged driving time should produce visual fatigue. Here, for the first time, we investigated the effects of driving time, a common inducer of driver fatigue, on two ocular parameters: the accommodative response (AR) and the intraocular pressure (IOP). A pre/post-test design has been used to assess the impact of driving time on both indices. Twelve participants (out of 17 recruited) completed the study (5 women, 24.42±2.84years old). The participants were healthy and active drivers with no visual impairment or pathology. They drove for 2h in a virtual driving environment. We assessed AR and IOP before and after the driving session, and also collected subjective measures of arousal and fatigue. We found that IOP and AR decreased (i.e., the accommodative lag increased) after the driving session (p=0.03 and p<0.001, respectively). Moreover, the nearest distances tested (20cm, 25cm, and 33cm) induced the highest decreases in AR (corrected p-values<0.05). Consistent with these findings, the subjective levels of arousal decreased and levels of fatigue increased after the driving session (all p-values<0.001). These results represent an innovative step towards an objective, valid, and reliable assessment of fatigue-impaired driving based on visual fatigue signs. PMID:27235337

  16. Comparative intraocular penetration of topical and injected cefuroxime.

    PubMed Central

    Jenkins, C D; Tuft, S J; Sheraidah, G; McHugh, D A; Buckley, R J

    1996-01-01

    AIMS: The choice of a prophylactic antibiotic for cataract surgery is dependent on its antibacterial activity and tissue penetration. The influence of the route and timing of administration of cefuroxime on its intraocular concentrations was examined. METHODS: 120 patients were recruited before cataract surgery into a prospective trial to compare the anterior chamber concentration of cefuroxime at a fixed time after administration by three routes. In a further 110 patients, the interval before sampling was varied in order to permit an examination of the kinetics of penetration. In another 10 patients, cefuroxime was given topically at the completion of surgery to assess the effect of a corneal wound on aqueous penetration. Cefuroxime concentrations were measured by high performance liquid chromatography on 0.2 ml samples of aqueous aspirated from the anterior chamber. Mean aqueous concentrations of cefuroxime for each group were compared using Student's t test. RESULTS: After 25 mg cefuroxime, mean aqueous concentrations increased in the order forniceal (< 0.1 microgram/ml) < topical (0.18 microgram/ml) < subconjunctival (2.31 microgram/ml) when sampled 12-24 minutes after administration. Aqueous concentrations of cefuroxime reached a peak between 80 and 110 minutes after both forniceal and peribulbar injection but were still rising at this time after subconjunctival injection. Topical application of 12.5 mg cefuroxime to eyes with a 10 mm corneal wound resulted in a mean aqueous concentration of 9.34 micrograms/ml. CONCLUSION: In the intact eye, only sub-conjunctival injection resulted in clinically significant aqueous concentrations of cefuroxime (> 1 microgram/ml) between 12 and 24 minutes after administration. For all routes, maximal aqueous concentrations were delayed by at least 80 minutes from administration. In the presence of a corneal wound, high aqueous levels of cefuroxime were rapidly attained after topical application. PMID:8949709

  17. Bevacizumab therapy normalizes the pathological intraocular environment beyond neutralizing VEGF

    PubMed Central

    Rogojina, Anna T.; Chalam, K.V.

    2010-01-01

    Purpose Vascular endothelial growth factor (VEGF) plays a key role in neovascularization by stimulating the proliferation and migration of vascular endothelial cells. The anti-VEGF therapy bevacizumab acts by binding to VEGF and preventing its effects. However, this linear interaction represents only a partial view of the pathobiology of neovascular diseases and the anti-VEGF treatment. To obtain an integrated view of the processes involved in VEGF-related ocular pathologies, we applied a systems approach and investigated whether intravitreal bevacizumab injections have a global effect in normalizing the ocular physiology perturbed by the disease. Methods We analyzed 90 analytes representing various pathophysiological processes in aqueous humor. The samples were obtained from eight patients receiving intravitreal bevacizumab injections for various ocular VEGF-related conditions. The samples were obtained before and after the injection and were analyzed using microbead technology developed by Luminex xMAP. Results Forty-three analytes were detected above the sensitivity of the assay both in pre- and post-injection samples. Of these, normal values of 41 analytes were known and these analytes were further analyzed. The detected analytes included relevant markers such as VEGF, C reactive protein, glutathione, and cytokines. We identified 24 markers that were perturbed more than 1.5 fold in diseased samples (pre-injection) compared to normal levels. The levels of perturbed analytes were compared in post-treatment samples. The results demonstrated an unequivocal trend toward normalization in post-treatment samples. Conclusions Our results show intraocular bevacizumab injections change the perturbed physiologic environment of the eye toward normalization. Its effects reached beyond neutralizing VEGF. The results also demonstrate that large-scale analysis of the aqueous, using a systems approach, could provide useful insight regarding ocular diseases, their

  18. Retreatments after multifocal intraocular lens implantation: an analysis

    PubMed Central

    Gundersen, Kjell Gunnar; Makari, Sarah; Ostenstad, Steffen; Potvin, Rick

    2016-01-01

    Purpose To determine the incidence and etiology of required retreatment after multifocal intraocular lens (IOL) implantation and to evaluate the methods and clinical outcomes of retreatment. Patients and methods A retrospective chart review of 416 eyes of 209 patients from one site that underwent uncomplicated cataract surgery with multifocal IOL implantation. Biometry, the IOL, and refractive data were recorded after the original implantation, with the same data recorded after retreatment. Comments related to vision were obtained both before and after retreatment for retreated patients. Results The multifocal retreatment rate was 10.8% (45/416 eyes). The eyes that required retreatment had significantly higher residual refractive astigmatism compared with those who did not require retreatment (1.21±0.51 D vs 0.51±0.39 D, P<0.01). The retreatment rate for the two most commonly implanted primary IOLs, blended bifocal (10.5%, 16/152) and bilateral trifocal (6.9%, 14/202) IOLs, was not statistically significantly different (P=0.12). In those requiring retreatment, refractive-related complaints were most common. Retreatment with refractive corneal surgery, in 11% of the eyes, and piggyback IOLs, in 89% of the eyes, was similarly successful, improving patient complaints 78% of the time. Conclusion Complaints related to ametropia were the main reasons for retreatment. Residual astigmatism appears to be an important determinant of retreatment rate after multifocal IOL implantation. Retreatment can improve symptoms for a high percentage of patients; a piggyback IOL is a viable retreatment option. PMID:27041983

  19. Nanosponge-Mediated Drug Delivery Lowers Intraocular Pressure

    PubMed Central

    Lambert, Wendi S.; Carlson, Brian J.; van der Ende, Alice E.; Shih, Grace; Dobish, Julia N.; Calkins, David J.; Harth, Eva

    2015-01-01

    Purpose We examined the efficacy of an extended-release drug delivery system, nanosponge (NS) encapsulated compounds, administered intravitreally to lower intraocular pressure (IOP) in mice. Methods Bilateral ocular hypertension was induced in mice by injecting microbeads into the anterior chamber. Hypertensive mice received NS loaded with ocular hypotensive drugs via intravitreal injection and IOP was monitored. Retinal deposition and retinal ganglion cell (RGC) uptake of Neuro-DiO were examined following intravitreal injection of Neuro-DiO-NS using confocal microscopy. Results Brimonidine-loaded NS lowered IOP 12% to 30% for up to 6 days (P < 0.02), whereas travoprost-NS lowered IOP 19% to 29% for up to 4 days (P < 0.02) compared to saline injection. Three bimatoprost NS were tested: a 400-nm NS and two 700-nm NS with amorphous (A-NS) or amorphous/crystalline (AC-NS) crosslinkers. A single injection of 400 nm NS lowered IOP 24% to 33% for up to 17 days compared to saline, while A-NS and AC-NS lowered IOP 22% to 32% and 18% to 26%, respectively, for up to 32 days (P < 0.046). Over time retinal deposition of Neuro-DiO increased from 19% to 71%; Neuro-DiO released from NS was internalized by RGCs. Conclusions A single injection of NS can effectively deliver ocular hypotensive drugs in a linear and continuous manner for up to 32 days. Also, NS may be effective at targeting RGCs, the neurons that degenerate in glaucoma. Translational Relevance Patient compliance is a major issue in glaucoma. The use of NS to deliver a controlled, sustained release of therapeutics could drastically reduce the number of patients that progress to vision loss in this disease. PMID:25599009

  20. Increased Intraocular Pressure and Hyperglycemic Level in Diabetic Patients

    PubMed Central

    Hymowitz, Maggie B.; Chang, Donny; Feinberg, Edward B.; Roy, Sayon

    2016-01-01

    Purpose To determine whether hyperglycemic levels as determined from high hemoglobin A1c (HbA1c) levels influence intraocular pressure (IOP) in patients with non-proliferative diabetic retinopathy (NPDR). Methods A retrospective chart review was performed on subjects with a diagnosis of NPDR and a corresponding HbA1c level measured within 90 days before or after an IOP measurement over a two-year period. Exclusion criteria included a diagnosis of glaucoma or treatment with IOP lowering medications or oral or topical steroids. Results Using 14.5mmHg as a baseline mean value for IOP, 42 subjects had an IOP < 14.5mmHg and mean HbA1c of 8.1±1.1, while 72 subjects had an IOP ≥ 14.5mmHg and a mean HbA1c of 9.0±2.1. Although there was an overlap in the confidence intervals, a significant difference (P = 0.01) in the mean HbA1c level was observed in regression analysis between the two groups. Importantly, diabetic subjects with elevated HbA1c levels rarely (<1%) exhibited reduced IOP levels. Conclusions Diabetic subjects with elevated HbA1c levels exhibited significantly higher IOPs compared to those with lower HbA1c levels. Findings from this study indicate an association between hyperglycemia and elevated IOP and that poor glycemic control may contribute to increased IOP levels in long-term diabetic patients. PMID:27002725

  1. Energy Efficiency of a New Trifocal Intraocular Lens

    NASA Astrophysics Data System (ADS)

    Vega, F.; Alba-Bueno, F.; Millán, M. S.

    2014-01-01

    The light distribution among the far, intermediate and near foci of a new trifocal intraocular lens (IOL) is experimentally determined, as a function of the pupil size, from image analysis. The concept of focus energy efficiency is introduced because, in addition to the theoretical diffraction efficiency of the focus, it accounts for other factors that are naturally presented in the human eye such as the level of spherical aberration (SA) upon the IOL, light scattering at the diffractive steps or the depth of focus. The trifocal IOL is tested in-vitro in two eye models: the aberration-free ISO model, and a so called modified-ISO one that uses an artificial cornea with positive spherical SA in instead. The SA upon the IOL is measured with a Hartmann-Shack sensor and compared to the values of theoretical eye models. The results show, for large pupils, a notorious reduction of the energy efficiency of the far and near foci of the trifocal IOL due to two facts: the level of SA upon the IOL is larger than the value the lens is able to compensate for and there is significant light scattering at the diffractive steps. On the other hand, the energy efficiency of the intermediate focus for small pupils is enhanced by the contribution of the extended depth of focus of the near and far foci. Thus, while IOLs manufacturers tend to provide just the theoretical diffraction efficiency of the foci to show which would be the performance of the lens in terms of light distribution among the foci, our results put into evidence that this is better described by using the energy efficiency of the foci.

  2. Blood Pressure Modifies Retinal Susceptibility to Intraocular Pressure Elevation

    PubMed Central

    He, Zheng; Nguyen, Christine T. O.; Armitage, James A.; Vingrys, Algis J.; Bui, Bang V.

    2012-01-01

    Primary open angle glaucoma affects more than 67 million people. Elevated intraocular pressure (IOP) is a risk factor for glaucoma and may reduce nutrient availability by decreasing ocular perfusion pressure (OPP). An interaction between arterial blood pressure and IOP determines OPP; but the exact contribution that these factors have for retinal function is not fully understood. Here we sought to determine how acute modifications of arterial pressure will affect the susceptibility of neuronal function and blood flow to IOP challenge. Anaesthetized (ketamine:xylazine) Long-Evan rats with low (∼60 mmHg, sodium nitroprusside infusion), moderate (∼100 mmHg, saline), or high levels (∼160 mmHg, angiotensin II) of mean arterial pressure (MAP, n = 5–10 per group) were subjected to IOP challenge (10–120 mmHg, 5 mmHg steps every 3 minutes). Electroretinograms were measured at each IOP step to assess bipolar cell (b-wave) and inner retinal function (scotopic threshold response or STR). Ocular blood flow was measured using laser-Doppler flowmetry in groups with similar MAP level and the same IOP challenge protocol. Both b-wave and STR amplitudes decreased with IOP elevation. Retinal function was less susceptible to IOP challenge when MAP was high, whereas the converse was true for low MAP. Consistent with the effects on retinal function, higher IOP was needed to attenuated ocular blood flow in animals with higher MAP. The susceptibility of retinal function to IOP challenge can be ameliorated by acute high BP, and exacerbated by low BP. This is partially mediated by modifications in ocular blood flow. PMID:22359566

  3. Handheld Automated Microsurgical Instrumentation for Intraocular Laser Surgery

    PubMed Central

    Yang, Sungwook; Lobes, Louis A.; Martel, Joseph N.; Riviere, Cameron N.

    2016-01-01

    Background and Objective Laser photocoagulation is a mainstay or adjuvant treatment for a variety of common retinal diseases. Automated laser photocoagulation during intraocular surgery has not yet been established. The authors introduce an automated laser photocoagulation system for intraocular surgery, based on a novel handheld instrument. The goals of the system are to enhance accuracy and efficiency and improve safety. Materials and Methods Triple-ring patterns are introduced as a typical arrangement for the treatment of proliferative retinopathy and registered to a preoperative fundus image. In total, 32 target locations are specified along the circumferences of three rings having diameters of 1, 2, and 3 mm, with a burn spacing of 600 μm. Given the initial system calibration, the retinal surface is reconstructed using stereo vision, and the targets specified on the preoperative image are registered with the control system. During automated operation, the laser probe attached to the manipulator of the active handheld instrument is deflected as needed via visual servoing in order to correct the error between the aiming beam and a specified target, regardless of any erroneous handle motion by the surgeon. A constant distance of the laser probe from the retinal surface is maintained in order to yield consistent size of burns and ensure safety during operation. Real-time tracking of anatomical features enables compensation for any movement of the eye. A graphical overlay system within operating microscope provides the surgeon with guidance cues for automated operation. Two retinal surgeons performed automated and manual trials in an artificial model of the eye, with each trial repeated three times. For the automated trials, various targeting thresholds (50–200 μm) were used to automatically trigger laser firing. In manual operation, fixed repetition rates were used, with frequencies of 1.0–2.5 Hz. The power of the 532 nm laser was set at 3.0 W with a

  4. Higher intraocular pressure is associated with leukoaraiosis among middle-aged and elderly Koreans without glaucoma or dementia

    PubMed Central

    Park, B-J; Kim, J-K; Lee, Y-J

    2014-01-01

    Aim Leukoaraiosis and high intraocular pressure are strongly associated with cardiovascular disease, vascular angiopathy, and geriatric syndrome. Until now, little is known about the relationship between intraocular pressure and leukoaraiosis in its preclinical stage. The aim of this study was to evaluate the association between intraocular pressure and leukoaraiosis among middle-aged and elderly Koreans without glaucoma or dementia. Methods We examined the relationship of intraocular pressure with leukoaraiosis at a preclinical stage in 753 Korean adults (474 men, 279 women; mean age 57.8±6.6 years). A multiple logistic regression analysis was performed in order to determine whether intraocular pressure is an independent determinant for leukoaraiosis. Results The overall prevalence of leukoaraiosis was 7.3%. Mean ocular pressure (±SD) was significantly higher in the leukoaraiosis group than the control group (14.3±2.9 and 13.5±2.9, respectively; P=0.028). In multiple logistic regression analysis, the odds ratio for leukoaraiosis was 1.18 (95% confidence interval: 1.06–1.31) for each 1 mm Hg increase in intraocular pressure. Conclusion Intraocular pressure was found to be independently and positively associated with leukoaraiosis. This finding indicates that higher intraocular pressure may be a useful additional measure in assessing the risk of leukoaraiosis in the clinical setting. PMID:24675583

  5. [Refraction after Implantation of Multifocal and Presbyopia-Correcting Intraocular Lenses].

    PubMed

    Kretz, F T A; Linz, K; Mueller, M; Gerl, M; Koss, M J; Gerl, R H; Auffarth, G U

    2015-08-01

    Nowadays, further developments in the field of intraocular lenses offer a higher level of spectacle independence for our patients. As light gets scattered on different focal points a wider range of defocus is created. This greater defocus area makes it more difficult for us to determine the objective or subjective refraction. This contribution is concerned with the difficulties of measuring visual acuity in different intraocular lens designs and different measurement distances. Measuring refraction after implantation of a multifocal intraocular lens is a complex procedure and the experience of the examiner plays a crucial role. Retinoscopy, keratometry and the defocus curve are reliable methods for testing, while the auto refractometer, bichromatic testing and the cross-cylinder have limitations. PMID:25927177

  6. Anti-tubercular therapy for intraocular tuberculosis: A systematic review and meta-analysis.

    PubMed

    Kee, Ae Ra; Gonzalez-Lopez, Julio J; Al-Hity, Aws; Gupta, Bhaskar; Lee, Cecilia S; Gunasekeran, Dinesh Visva; Jayabalan, Nirmal; Grant, Robert; Kon, Onn Min; Gupta, Vishali; Westcott, Mark; Pavesio, Carlos; Agrawal, Rupesh

    2016-01-01

    Intraocular tuberculosis remains a diagnostic and management conundrum for both ophthalmologists and pulmonologists. We analyze the efficacy and safety of anti-tubercular therapy (ATT) in patients with intraocular tuberculosis and factors associated with favorable outcome. Twenty-eight studies are included in this review, with a total of 1,917 patients. Nonrecurrence of inflammation was observed in pooled estimate of 84% of ATT-treated patients (95% CI 79-89). There was minimal difference in the outcome between patients treated with ATT alone (85% successful outcome; 95% CI 25-100) and those with concomitant systemic corticosteroid (82%; 95% CI 73-90). The use of ATT may be of benefit to patients with suspected intraocular tuberculosis; however, this conclusion is limited by the lack of control group analysis and standardized recruitment and treatment protocols. We propose further prospective studies to better establish the efficacy of ATT and ascertain the factors associated with favorable treatment outcomes. PMID:26970263

  7. STS-41 crewmembers conduct DSO 0472 Intraocular Pressure on OV-103's middeck

    NASA Technical Reports Server (NTRS)

    1990-01-01

    STS-41 crewmembers conduct Detailed Supplementary Objective (DSO) 0472 Intraocular Pressure on the middeck of Discovery, Orbiter Vehicle (OV) 103. Mission Specialist (MS) William M. Shepherd rests his head on the stowed treadmill while Pilot Robert D. Cabana, holding Shepherd's eye open, prepares to measure Shepherd's intraocular pressure using a tono pen (in his right hand). Objectives include: establishing a database of changes in intraocular pressures that can be used to evaluate crew health; validating ten degree head down bedrest as a model for cephalad fluid shifts in microgravity; facilitating the interpretation of data by providing a quantative measure of microgravity induced cephalad fluid shifts; and validating the tono pen as an effective tool for diagnostic and scientific data collection.

  8. Laser-triggered intraocular implant to induce photodynamic therapy for posterior capsule opacification prevention.

    PubMed

    Zhang, Zhaoguo; Huang, Wenyong; Lei, Ming; He, Yuanfeng; Yan, Mina; Zhang, Xuefei; Zhao, Chunshun

    2016-02-10

    Posterior capsule opacification (PCO) is one of the main reasons for loss of vision again after cataract surgery. In this study, intraocular lenses were modified with indocyanine green (ICG) and sealed up with PLGA to form long-term intraocular implants (ICG-IOL). When triggered by laser, ICG-IOL would induce photodynamic therapy (PDT). In-vitro cell viability assay and scratch wound healing assay demonstrated that ICG-IOL could effectively inhibit HLEpiC proliferation and migration without causing damage to the cells far away from it. Laser attenuation test indicated that ICG-IOL could be applied in vivo. In-vivo pharmacodynamics and safety study showed that ICG-IOL could significantly prevent the occurrence of PCO and was safe for intraocular normal tissue. All these results suggested that ICG-IOL would be a very promising candidate for PCO prevention. PMID:26456263

  9. Current Perspectives of Prophylaxis and Management of Acute Infective Endophthalmitis.

    PubMed

    Tranos, Paris; Dervenis, Nikolaos; Vakalis, Athanasios N; Asteriadis, Solon; Stavrakas, Panagiotis; Konstas, Anastasios G P

    2016-05-01

    Endophthalmitis is an intraocular inflammatory condition which may or may not be caused by infective agents. Noninfectious (sterile) endophthalmitis may be attributable to various causes including postoperative retained soft lens matter or toxicity following introduction of other agents into the eye. Infectious endophthalmitis is further subdivided into endogenous and exogenous. In endogenous endophthalmitis there is hematogenous spread of organisms from a distant source of infection whereas in exogenous endophthalmitis direct microbial inoculation may occur usually following ocular surgery or penetrating eye injury with or without intraocular foreign bodies. Acute infective endophthalmitis is usually exogenous induced by inoculation of pathogens following ocular surgery, open-globe injury and intravitreal injections. More infrequently the infective source is internal and septicemia spreads to the eye resulting in endogenous endophthalmitis. Several risk factors have been implicated including immunosuppression, ocular surface abnormalities, poor surgical wound construction, complicated cataract surgery with vitreous loss and certain types of intraocular lens. Comprehensive guidelines and recommendations on prophylaxis and monitoring of surgical cases have been proposed to minimize the risk of acute endophthalmitis. Early diagnosis and prompt management of infective endophthalmitis employing appropriately selected intravitreal antibiotics are essential to optimize visual outcome. PMID:26935830

  10. Correlation between Intraocular Pressure Fluctuation with Postural Change and Postoperative Intraocular Pressure in Relation to the Time Course after Trabeculectomy

    PubMed Central

    Tenkumo, Kaori; Nitta, Eri; Sato, Shino

    2014-01-01

    Background. To investigate the correlation between intraocular pressure (IOP) fluctuation with postural change and IOP in relation to the time course after trabeculectomy. Methods. A total of 29 patients who had previously undergone primary trabeculectomy with mitomycin C were examined. IOP was obtained at 1, 2, 3, 6, and 12 months and then every 6 months postoperatively. Results. The postural IOP difference before surgery was 3.0 ± 1.8 mmHg, which was reduced to 0.9 ± 1.1 mmHg at 1 month, 1.0 ± 1.0 mmHg at 2 months, 1.3 ± 2.0 mmHg at 3 months, 1.3 ± 1.4 mmHg at 6 months, 1.4 ± 1.5 mmHg at 12 months, and 1.1 ± 0.7 mmHg at 18 months after trabeculectomy (P < 0.01 each visit). The filtering surgery failed in 7 out of 29 eyes. Postural IOP changes were less than 3 mmHg in those patients who did not require needle revision at every visit. However, in patients who did require needle revision, the increase in the posture-induced IOP was greater than 3 mmHg prior to the increase in the sitting position IOP. Conclusions. Assessment of postural IOP changes after trabeculectomy might be potentially useful for predicting IOP changes after trabeculectomy. PMID:25136454

  11. Intraocular Pressure Regulation: Findings of Pulse-Dependent Trabecular Meshwork Motion Lead to Unifying Concepts of Intraocular Pressure Homeostasis

    PubMed Central

    2014-01-01

    Abstract Intraocular pressure (IOP) is the only treatable risk factor in glaucoma, one of the world's leading causes of blindness. Mechanisms that maintain IOP within a normal range have been poorly understood in contrast to intrinsic mechanisms that regulate systemic blood pressure. Vessel walls experience continuous pulse-induced cyclic pressure and flow. Pressure-dependent wall stress and flow-dependent shear stress provide sensory signals that initiate mechanotransduction responses. The responses optimize vessel wall elasticity, compliance and lumen size, providing a feedback loop to maintain intrinsic pressure homeostasis. Aqueous humor is part of a vascular circulatory loop, being secreted into the anterior chamber of the eye from the vasculature, then returning to the vasculature by passing through the trabecular meshwork (TM), a uniquely modified vessel wall interposed between the anterior chamber and a vascular sinus called Schlemm's canal (SC). Since pressure in circulatory loops elsewhere is modulated by cyclic stresses, one might predict similar pressure modulation in the aqueous outflow system. Recent laboratory evidence in fact demonstrates that cyclic IOP changes alter aqueous outflow while increasing cellularity and contractility of TM cells. Cyclic changes also lead to alterations in gene expression, changes in cytoskeletal networks and modulation of signal transduction. A new technology, phase-based optical coherence tomography, demonstrates in vivo pulse-dependent TM motion like that elsewhere in the vasculature. Recognition of pulse-dependent TM motion provides a linkage to well-characterized mechanisms that provide pressure homeostasis in the systemic vasculature. The linkage may permit unifying concepts of pressure control and provide new insights into IOP homeostatic mechanisms. PMID:24359130

  12. Comparison of visual outcomes after implantation of diffractive trifocal toric intraocular lens and a diffractive apodized bifocal toric intraocular lens

    PubMed Central

    Gundersen, Kjell Gunnar; Potvin, Rick

    2016-01-01

    Purpose The aim of this study was to compare a new diffractive trifocal toric lens with an apodized diffractive bifocal toric lens in terms of refractive and visual acuity (VA) outcomes, including low-contrast VA (LCVA), as well as the patient’s visual function 3 months after implantation. Patients and methods This is a randomized prospective study involving bilateral implantation of a trifocal toric or a bifocal toric lens. At 3 months postoperatively, the subject’s vision was tested both uncorrected and with his/her best distance correction at: distance (4 m), intermediate (63 cm), and near (40 cm). Binocular defocus curves were measured with no correction and with the subject’s best distance correction in place. Quality of vision was measured using the National Eye Institute Visual Function Questionnaire. Results A total of 22 patients were enrolled (eleven in each group). There was no statistically significant difference in the absolute change in measured rotation between 1 month and 3 months postoperatively between the two intraocular lens (IOL) groups (P=0.98). At 3 months, the postoperative refraction and distance VA by eye were similar between groups. There was no statistically significant difference in the measured LCVA between groups (P=0.39). The defocus curve showed that at 67 cm, the trifocal toric lens had statistically significantly better VA when compared to the bifocal toric lens. There were no statistically significant differences by group for any of the National Eye Institute Visual Function Questionnaire scores (P>0.26 in all cases). Conclusion The trifocal toric IOL improved the intermediate vision without negatively impacting visual function and distance, near, or low-contrast VA when compared to a bifocal toric IOL. The toric component of the trifocal lens effectively reduced astigmatism and provided good rotational stability. PMID:27051269

  13. Apparatus and method for non-contact, acoustic resonance determination of intraocular pressure

    DOEpatents

    Sinha, Dipen N.; Wray, William O.

    1994-01-01

    Apparatus and method for measuring intraocular pressure changes in an eye under investigation by detection of vibrational resonances therein. An ultrasonic transducer operating at its resonant frequency is amplitude modulated and swept over a range of audio frequencies in which human eyes will resonate. The output therefrom is focused onto the eye under investigation, and the resonant vibrations of the eye observed using a fiber-optic reflection vibration sensor. Since the resonant frequency of the eye is dependent on the pressure therein, changes in intraocular pressure may readily be determined after a baseline pressure is established.

  14. Intraocular/Intracranial pressure mismatch hypothesis for visual impairment syndrome in space.

    PubMed

    Zhang, Li-Fan; Hargens, Alan R

    2014-01-01

    Visual impairment intracranial pressure syndrome (VIIP) is considered a major risk for future human spaceflight. Loss of hydrostatic pressure gradients in vascular and cerebrospinal fluid systems due to the removal of gravity associated with subsequent intracranial and intraocular fluid shifts and the resulting intraocular/intracranial pressure mismatch might be important etiology factors causingVIIP syndrome. Acclimation changes in the ocular and cerebral circulation and the two fluid systems during chronic microgravity exposure and their underlying mechanisms need further elucidation. Relevant findings may help to validate the pressure differential hypothesis for VlIP syndrome and to evaluate whether a gravity based countermeasure is needed. PMID:24479265

  15. Fulminant Panuveitis following Iris Suture Fixation of Posterior Chamber Intraocular Lens

    PubMed Central

    Mansour, Ahmad M.; Awwad, Shady T.

    2013-01-01

    We present a case of fulminant panuveitis following iris suture fixation of a posterior chamber intraocular lens. We hypothesize that the zonular dehiscence allowed the inflammatory cells in the anterior compartment to gain access to the posterior segment mimicking endophthalmitis or toxic anterior segment syndrome. Also certain bulky lens designs, like the current Rayner hydrophilic acrylic lens, are difficult to manipulate and hold in the optic capture position, and hence the iris fixation of these lenses can be traumatic and lengthy. It is advised to exchange such lenses with 3-piece intraocular lenses that are easy to fixate. PMID:23476849

  16. New two-point scleral-fixation technique for foldable intraocular lenses with four hollow haptics.

    PubMed

    Liu, He-Ting; Jiang, Zheng-Xuan; Tao, Li-Ming

    2016-01-01

    The study was to report a new two-point scleral-fixation technique for foldable intraocular lenses with four haptics. Lenses were slid into the anterior chamber from a 2.8 mm corneal incision and fixed under two sclera flaps at two opposite points. The postoperative best-corrected visual acuities (BCVAs) of all patients were significantly better than their preoperative BCVA. The results demonstrate that two-point, scleral fixations of foldable, intraocular lenses might be practicable and effective. PMID:27158623

  17. New two-point scleral-fixation technique for foldable intraocular lenses with four hollow haptics

    PubMed Central

    Liu, He-Ting; Jiang, Zheng-Xuan; Tao, Li-Ming

    2016-01-01

    The study was to report a new two-point scleral-fixation technique for foldable intraocular lenses with four haptics. Lenses were slid into the anterior chamber from a 2.8 mm corneal incision and fixed under two sclera flaps at two opposite points. The postoperative best-corrected visual acuities (BCVAs) of all patients were significantly better than their preoperative BCVA. The results demonstrate that two-point, scleral fixations of foldable, intraocular lenses might be practicable and effective. PMID:27158623

  18. Symbolic algebra approach to the calculation of intraocular lens power following cataract surgery

    NASA Astrophysics Data System (ADS)

    Hjelmstad, David P.; Sayegh, Samir I.

    2013-03-01

    We present a symbolic approach based on matrix methods that allows for the analysis and computation of intraocular lens power following cataract surgery. We extend the basic matrix approach corresponding to paraxial optics to include astigmatism and other aberrations. The symbolic approach allows for a refined analysis of the potential sources of errors ("refractive surprises"). We demonstrate the computation of lens powers including toric lenses that correct for both defocus (myopia, hyperopia) and astigmatism. A specific implementation in Mathematica allows an elegant and powerful method for the design and analysis of these intraocular lenses.

  19. Apparatus and method for non-contact, acoustic resonance determination of intraocular pressure

    DOEpatents

    Sinha, D.N.; Wray, W.O.

    1994-12-27

    The apparatus and method for measuring intraocular pressure changes in an eye under investigation by detection of vibrational resonances therein. An ultrasonic transducer operating at its resonant frequency is amplitude modulated and swept over a range of audio frequencies in which human eyes will resonate. The output therefrom is focused onto the eye under investigation, and the resonant vibrations of the eye observed using a fiber-optic reflection vibration sensor. Since the resonant frequency of the eye is dependent on the pressure therein, changes in intraocular pressure may readily be determined after a baseline pressure is established. 3 figures.

  20. Iris-claw, retropupillary-fixated, aphakic intraocular lens implantation for traumatic aphakia following penetrating keratoplasty

    PubMed Central

    Anbari, Anas A.

    2015-01-01

    Summary We report the correction of aphakia using an iris-claw, aphakic intraocular lens (IOL) fixated in a retropupillary location in a 17-year-old young man who suffered blunt trauma to his eye 5 months after penetrating keratoplasty (PKP). There were no intraoperative complications. At 21 months after implantation, the patient’s uncorrected distance visual acuity was 20/28; his corrected distance visual acuity was 20/22, with +0.50 −3.00 × 155. Intraocular pressure was normal, and endothelial cell count was 1798 cells/mm2.

  1. Phakic Intraocular Lenses for the Treatment of Refractive Errors

    PubMed Central

    2009-01-01

    Executive Summary Objective The objective of this analysis is to review the effectiveness, safety, and cost-effectiveness of phakic intraocular lenses (pIOLs) for the treatment of myopia, hyperopia, and astigmatism. Clinical Need: Condition and Target Population Refractive Errors Refractive errors occur when the eye cannot focus light properly. In myopia (near- or short-sightedness), distant objects appear blurry because the axis of the eye is too long or the cornea is too steep, so light becomes focused in front of the retina. Hyperopia (far sightedness) occurs when light is focused behind the retina causing nearby objects to appear blurry. In astigmatism, blurred or distorted vision occurs when light is focused at two points rather than one due to an irregularly shaped cornea or lens. Refractive errors are common worldwide, but high refractive errors are less common. In the United States, the prevalence of high myopia (≤ −5 D) in people aged 20 to 39, 40 to 59, and 60 years and older is 7.4% (95% confidence interval [CI], 6.5% – 8.3%), 7.8% (95% CI, 6.4% – 8.6%), and 3.1% (95% CI, 2.2% – 3.9%), respectively. The prevalence of high hyperopia (≥ 3 D) is 1.0% (95% CI, .6% – 1.4%), 2.4% (95% CI, 1.7% – 3.0%), and 10.0% (95% CI, 9.1% – 10.9%) for the same age groupings. Finally, the prevalence of astigmatism (≥ 1 D cylinder) is 23.1% (95% CI, 21.6% – 24.5%), 27.6% (95% CI, 25.8% – 29.3%) and 50.1% (48.2% – 52.0%). Low Vision According to the Ontario Schedule of Benefits, low visual acuity is defined by a best spectacle corrected visual acuity (BSCVA) of 20/50 (6/15) or less in the better eye and not amenable to further medical and/or surgical treatment. Similarly, the Ontario Assistive Devices Program defines low vision as BSCVA in the better eye in the range of 20/70 or less that cannot be corrected medically, surgically, or with ordinary eyeglasses or contact lenses. Estimates of the prevalence of low vision vary. Using the criteria of

  2. Central corneal thickness and intraocular pressure in premature infants.

    PubMed

    Sekeroglu, Mehmet Ali; Hekimoglu, Emre; Petricli, İkbal Seza; Karakaya, Jale; Ozcan, Beyza; Yucel, Husniye; Kavurt, Aysen Sumru; Bas, Ahmet Yagmur

    2015-12-01

    To evaluate the central corneal thickness (CCT) and intraocular pressure (IOP) of premature infants and to document correlation of them with gestational age, chronological age, and birth weight of infants. Using a hand-held applanation tonometer and a portable pachymeter, IOP and CCT of 170 premature infants were measured just before initial retinopathy of prematurity screening examination and re-measured 4 weeks after the first visit. The CCT and IOP were positively correlated during the first (r = 0.616, p < 0.001) and second (r = 0.564, p < 0.001) visits. The mean CCT at first and second visits were 568.1 ± 22.1 (527-628) and 561.6 ± 21.4 (520-619) µm, consecutively (p < 0.001). Gestational age, chronological age and birth weight of infants were found to be negatively correlated with CCT at first (r = -0.751, p < 0.001; r = -0.745, p < 0.001; r = -0.581, p < 0.001, consecutively) and second (r = -0.729, p < 0.001; r = -0.729, p < 0.001; r = -0.555, p < 0.001, consecutively) visits. The mean IOP at first and second visits were 14.1 ± 1.9 (11-19) and 13.7 ± 1.7 (11-18) mmHg, consecutively (p < 0.001). Gestational age, chronological age, and birth weight of infants were found to be negatively correlated with IOP at first (r = -0.724, p < 0.001; r = -0.715, p < 0.001; r = -0.558, p < 0.001, consecutively) and second (r = -0.704, p < 0.001; r = -0.703, p < 0.001; r = -0.518, p < 0.001, consecutively) visits. CCT and IOP of the premature infants with a smaller gestational age were found to be higher (p < 0.001 for both). Premature infants with smaller gestational age have higher CCT and IOP values when compared to older infants. These values tend to become lower 4 weeks after the first examination as infants become older. The CCT and IOP were positively correlated with each other and both were negatively correlated with gestational age, chronological age, and birth weight during first and second visits. PMID:26286757

  3. [Postoperative opacification of posterior chamber intraocular lenses - a review].

    PubMed

    Schmidbauer, J M; Werner, L; Apple, D J; Pandey, S K; Izak, A M; Trivedi, R H; Macky, T A; Auffarth, G U; Peng, Q; Arthur, S N; Escobar-Gomez, M; Ma, L; Vargas, L G

    2001-09-01

    Postoperative opacification of intraocular lenses (IOLs) is a very unpleasant complication for the ophthalmic surgeon and the patient. We report on our experiences with opacification of different foldable IOL designs and rigid poly (methyl methacrylate) (PMMA) posterior chamber lenses.1. Snowflake degeneration of PMMA IOLs: This condition is an unanticipated and surprising late postoperative finding 8 to 15 years after implantation. In our opinion, this complication is probably not related to the PMMA biomaterial itself, but rather it appears to represent a manufacturing problem that has affected a selected, albeit large number of lenses manufactured in the 1980s-mid 1990s.2. Degeneration of UV absorber material and calcium deposits within the optic of hydrophilic IOLs: Two years postoperatively degenerations of UV absorber material and calcium deposits within the optic of single piece hydrophilic acrylic lenses SC60B-OUV manufactured by MDR (Medical developmental research Inc. Clearwater FL, USA) can occur. Although the precise mechanism is not fully known, it was assumed that these opacifications are due to premature aging of the UV blocking agent incorporated in the lens biomaterial and calcification.3. Calcification on the surface of the Bausch & Lomb Hydroviewtrade mark IOLs: Twelve to 15 months postoperatively granular surface calcifications in Hydroviewtrade mark IOLs occured. The mechanism is not fully understood. According to Bausch and Lomb studies, part of the components of the packaging contained silicone, which may have come off the packaging onto the lens optic, where it then appears to be a catalyst for calcium precipitation. The manufacturer has correlated a change in packaging with the appearance of the opacification. The manufacturer now believes that this problem has been solved. However, final verification will require a careful 1 - 2 years clinical study.4. Glistenings in the hydrophobic acrylic AcrySoftrade mark IOLs: The time frame of

  4. Intraocular pressure-lowering combination therapies with prostaglandin analogues.

    PubMed

    Aptel, Florent; Chiquet, Christophe; Romanet, Jean-Paul

    2012-07-01

    Intraocular pressure (IOP) reduction is currently the only therapeutic approach demonstrated to preserve visual function in patients with glaucoma. The first line of glaucoma treatment consists of topical IOP-lowering medications, usually initiated as monotherapy. A significant proportion of patients require more than one medication to reach a target IOP at which optic nerve damage will not progress. As prostaglandin analogues (PGAs) are the most effective class for reducing IOP, one of the other commonly used classes (β-adrenoceptor antagonist [β-blocker], carbonic anhydrase inhibitor or α(2)-adrenoceptor agonist) is frequently combined with a PGA. In the last decade, the use of fixed combinations containing two medications in a single bottle has steadily increased. Fixed combinations have the potential to simplify the dosing regimen, increase patient adherence, avoid the washout effect of the second drop on the first medication instilled, decrease exposure to preservatives and, sometimes, reduce the cost of treatment. Clinical trials have evaluated PGA-based fixed combinations versus unfixed combinations (individual components administered concomitantly) or versus individual monotherapies; however, any advantage that the fixed combinations may have in terms of IOP-lowering efficacy is still debated. For these reasons, the PGA-based fixed combinations are not approved by regulatory authorities in some countries, such as the US. We review the published studies evaluating the efficacy and tolerability of the IOP-lowering unfixed and fixed combination therapies with PGAs. Regarding unfixed combinations, the review shows that α(2)-adrenergic agonists-PGA and carbonic anhydrase inhibitor-PGA combinations seem to be at least as effective at reducing IOP as the β-blocker-PGA combinations. As for the fixed combinations, the review shows that the three PGA-timolol fixed combinations are more effective than their component medications used separately as monotherapy and

  5. Drug loading of foldable commercial intraocular lenses using supercritical impregnation.

    PubMed

    Bouledjouidja, A; Masmoudi, Y; Sergent, M; Trivedi, V; Meniai, A; Badens, E

    2016-03-16

    The drug delivery through intraocular lenses (IOLs) allows the combination of cataract surgery act and postoperative treatment in a single procedure. In order to prepare such systems, "clean" supercritical CO2 processes are studied for loading commercial IOLs with ophthalmic drugs. Ciprofloxacin (CIP, an antibiotic) and dexamethasone 21-phosphate disodium (DXP, an anti-inflammatory drug) were impregnated into foldable IOLs made from poly-2-hydroxyethyl methacrylate (P-HEMA). A first pre-treatment step was conducted in order to remove absorbed conditioning physiological solution. Supercritical impregnations were then performed by varying the experimental conditions. In order to obtain transparent IOLs and avoid the appearance of undesirable foaming, it was necessary to couple slow pressurization and depressurization phases during supercritical treatments. The impregnation yields were determined through drug release studies. For both drugs, release studies show deep and reproducible impregnation for different diopters. For the system P-HEMA/CIP, a series of impregnations was performed to delimit the experimental range at two pressures (80 and 200 bar) in the presence or absence of ethanol as a co-solvent for two diopters (+5.0 D and +21.0 D). Increase in pressure in the absence of a co-solvent resulted in improved CIP impregnation. The addition of ethanol (5 mol%) produced impregnation yields comparable to those obtained at 200 bar without co-solvent. A response surface methodology based on experimental designs was used to study the influence of operating conditions on impregnation of IOLs (+21.0 D) in the absence of co-solvent. Two input variables with 5 levels each were considered; the pressure (80-200 bar) and the impregnation duration (30-240 min). CIP impregnation yields ranging between 0.92 and 3.83 μg CIP/mg IOL were obtained from these experiments and response surface indicated the pressure as a key factor in the process. The DXP impregnation in P-HEMA was

  6. Reference intervals for intraocular pressure measured by rebound tonometry in ten raptor species and factors affecting the intraocular pressure.

    PubMed

    Reuter, Anne; Müller, Kerstin; Arndt, Gisela; Eule, Johanna Corinna

    2011-09-01

    Intraocular pressure (IOP) was measured with the TonoVet rebound tonometer in 10 raptor species, and possible factors affecting IOP were investigated. A complete ophthalmic examination was performed, and IOP was assessed in 2 positions, upright and dorsal recumbency, in 237 birds belonging to the families Accipitridae, Falconidae, Strigidae, and Tytonidae. Mean IOP values of healthy eyes were calculated for each species, and differences between families, species, age, sex, left and right eye, as well as the 2 body positions were evaluated. Physiologic fluctuations of IOP were assessed by measuring IOP serially for 5 days at the same time of day in 15 birds of 3 species. Results showed IOP values varied by family and species, with the following mean IOP values (mm Hg +/- SD) determined: white-tailed sea eagle (Haliaeetus albicilla), 26.9 +/- 5.8; red kite (Milvus milvus), 13.0 +/- 5.5; northern goshawk (Accipiter gentilis), 18.3 +/- 3.8; Eurasian sparrowhawk (Accipiter nisus), 15.5 +/- 2.5; common buzzard (Buteo buteo), 26.9 +/- 7.0; common kestrel (Falco tinnunculus), 9.8 +/- 2.5; peregrine falcon, (Falco peregrinus), 12.7 +/- 5.8; tawny owl (Strix aluco), 9.4 +/- 4.1; long-eared owl (Asio otus), 7.8 +/- 3.2; and barn owl (Tyto alba), 10.8 +/- 3.8. No significant differences were found between sexes or between left and right eyes. In goshawks, common buzzards, and common kestrels, mean IOP was significantly lower in juvenile birds than it was in adult birds. Mean IOP differed significantly by body position in tawny owls (P = .01) and common buzzards (P = .04). By measuring IOP over several days, mean physiologic variations of +/- 2 mm Hg were detected. Differences in IOP between species and age groups should be considered when interpreting tonometric results. Physiologic fluctuations of IOP may occur and should not be misinterpreted. These results show that rebound tonometry is a useful diagnostic tool in measuring IOP in birds of prey because it provides rapid

  7. Evaluation of Different Power of Near Addition in Two Different Multifocal Intraocular Lenses

    PubMed Central

    Unsal, Ugur; Baser, Gonen

    2016-01-01

    Purpose. To compare near, intermediate, and distance vision and quality of vision, when refractive rotational multifocal intraocular lenses with 3.0 diopters or diffractive multifocal intraocular lenses with 2.5 diopters near addition are implanted. Methods. 41 eyes of 41 patients in whom rotational +3.0 diopters near addition IOLs were implanted and 30 eyes of 30 patients in whom diffractive +2.5 diopters near addition IOLs were implanted after cataract surgery were reviewed. Uncorrected and corrected distance visual acuity, intermediate visual acuity, near visual acuity, and patient satisfaction were evaluated 6 months later. Results. The corrected and uncorrected distance visual acuity were the same between both groups (p = 0.50 and p = 0.509, resp.). The uncorrected intermediate and corrected intermediate and near vision acuities were better in the +2.5 near vision added intraocular lens implanted group (p = 0.049, p = 0.005, and p = 0.001, resp.) and the uncorrected near vision acuity was better in the +3.0 near vision added intraocular lens implanted group (p = 0.001). The patient satisfactions of both groups were similar. Conclusion. The +2.5 diopters near addition could be a better choice in younger patients with more distance and intermediate visual requirements (driving, outdoor activities), whereas the + 3.0 diopters should be considered for patients with more near vision correction (reading). PMID:27340560

  8. A case of presumed acute retinal necrosis after intraocular foreign body injury.

    PubMed

    Park, Sung Who; Byon, Ik Soo; Park, Hyun Jun; Lee, Ji Eun; Oum, Boo Sup

    2013-01-01

    The aim of this study was to report a case of acute retinal necrosis (ARN) after intraocular foreign body removal. A 32-year-old male presented with visual loss in the left eye. He was hit by an iron fragment while he was hammering. An intraocular foreign body was found with corneal laceration and traumatic cataract. On the day he was injured, primary closure of the laceration, lensectomy, and vitrectomy were performed, and the foreign body was removed. The day after the operation, there was no sign of retinal detachment or retinitis. Two days after the operation, retinal necrosis and accompanying vitreous inflammation were noted in the far periphery. On day 3, the necrosis spread circumferentially and inflammation became more distinct. ARN was presumed and intravenous acyclovir was administered. The necrotic areas were reduced 2 days later, and were resolved in 1 month. The final visual acuity in his left eye was 20/20 after implantation of an intraocular lens. This case is the first report of ARN after penetrating injury and an intraocular foreign body. ARN may develop after open-globe injury. PMID:23658473

  9. Novel Intraocular Therapy in Non-infectious Uveitis of the Posterior Segment of the Eye

    PubMed Central

    Mikhail, Michael; Sallam, Ahmed

    2013-01-01

    This article reviews the new clinically relevant data regarding the intraocular treatment of non-infectious uveitis. Triamcinolone acetonide is the most commonly used intravitreal corticosteroid for treatment of uveitis and uveitic macular oedema. The drug is available at low cost but it is associated with a high risk of raised intraocular pressure (IOP) and cataract and is not licensed for intraocular use. Dexamethasone implant (Ozurdex®) appears to have a better safety profile, and a slightly long-lasting effect than triamcinolone acetonide. Fluocinolone acetonide implant (Retisert®) implant allows the release of corticosteroids at a constant rate over a 3-year period, but it requires surgical placement and its use is associated with a very high risk of cataracts and raised intraocular pressure. Iluvien® is another fluocinolone acetonide implant that could represent a more convenient treatment option for such cases in the future as it can be inserted into the vitreous cavity through 25-gauge injector system in an outpatient setting. To circumvent the risks associated with corticosteroids use, non-corticosteroids related therapeutics including intravitreal methotrexate; anti-vascular endothelial growth factor treatments and intravitreal sirolimus have been recently developed. PMID:24822232

  10. Bilateral anterior chamber intraocular lenses dislocation in a patient with habitual eye rubbing.

    PubMed

    Poh, E P; Fariza, N Nor; Mariam, I

    2005-08-01

    A 61-year-old Chinese man presented with bilateral posteriorly dislocated anterior chamber intraocular lenses (AC IOLs) one year after successful vitrectomy, removal of bilateral dislocated mature cataractous lenses and AC IOLs implantation. A thorough clinical evaluation revealed habitual eye rubbing as the only possible cause. PMID:16379196

  11. Fifty-year follow-up and Strampelli anterior chamber intraocular lens

    PubMed Central

    Oakley, Carmen L.; Nigro, Matthew A.; Vote, Brendan J.

    2015-01-01

    The Strampelli anterior chamber intraocular lens was created in 1953, and was primarily used to treat myopia and aphakia. Due to the positioning of the lens, it was associated with a number of complications, and was later modified to decrease the rate of significant complications, including endothelial cell loss. This paper describes a 62-year-old man, who has had a Strampelli intraocular lens (IOL) in situ for 52 years, with relatively few complications. The case provides a framework for reflection on the significant advances in the development of IOLs since the Strampelli era. The Strampelli anterior chamber intraocular lens was created in 1953, and was primarily used to treat myopia and aphakia. Due to the positioning of the lens, it was associated with a number of complications, and was later modified to decrease the rate of significant complications, including endothelial cell loss. This paper describes a 62-year-old man, who has had a Strampelli intraocular lens (IOL) in situ for 52 years, with relatively few complications. The case provides a framework for reflection on the significant advances in the development of IOLs since the Strampelli era.

  12. Intravitreal injection of anti-VEGF and diagnosis of primary intraocular central nervous system lymphoma.

    PubMed

    Gambrelle, J; Missotten, G; Delhoum, S; Desjardins, L

    2013-05-01

    We report a case of primary intraocular central nervous system (CNS) lymphoma in a patient previously treated with intravitreal anti-vascular endothelial growth factor (VEGF) injections for age-related macular degeneration (AMD). An 88-year-old woman, with past medical history significant for bilateral age-related macular degeneration (AMD) treated with intravitreal ranibizumab injections for 1 year, was referred to our department for bilateral vitritis diagnosed 10 days after the last anti-VEGF injection. A complete uveitis work-up including aqueous humour analysis, brain MRI and vitreous biopsy enabled us to confirm the diagnosis of primary intraocular CNS lymphoma. To the best of our knowledge, this is the first report of the diagnosis of primary intraocular CNS lymphoma in a patient treated with anti-VEGF for AMD. The differential diagnosis of vitritis in elderly patients is relatively broad. Endophthalmitis and uveitis have been described after anti-VEGF injections. In such a situation, there is actually a risk of missing the diagnosis of intraocular lymphoma in the mistaken belief that the observed vitritis may be a reaction to administered anti-VEGFs. If no direct time-relationship with the anti-VEGF injections can be found, a classic vitritis work-up should be performed. Our observation suggests that ranibizumab, at the dosage used for AMD, does not impede the spread of CNS lymphoma in the eye nor interfere with cytological diagnosis. PMID:23306179

  13. Deformable Surface Accommodating Intraocular Lens: Second Generation Prototype Design Methodology and Testing

    PubMed Central

    McCafferty, Sean J.; Schwiegerling, Jim T.

    2015-01-01

    Purpose: Present an analysis methodology for developing and evaluating accommodating intraocular lenses incorporating a deformable interface. Methods: The next generation design of extruded gel interface intraocular lens is presented. A prototype based upon similar previously in vivo proven design was tested with measurements of actuation force, lens power, interface contour, optical transfer function, and visual Strehl ratio. Prototype verified mathematical models were used to optimize optical and mechanical design parameters to maximize the image quality and minimize the required force to accommodate. Results: The prototype lens produced adequate image quality with the available physiologic accommodating force. The iterative mathematical modeling based upon the prototype yielded maximized optical and mechanical performance through maximum allowable gel thickness to extrusion diameter ratio, maximum feasible refractive index change at the interface, and minimum gel material properties in Poisson's ratio and Young's modulus. Conclusions: The design prototype performed well. It operated within the physiologic constraints of the human eye including the force available for full accommodative amplitude using the eye's natural focusing feedback, while maintaining image quality in the space available. The parameters that optimized optical and mechanical performance were delineated as those, which minimize both asphericity and actuation pressure. The design parameters outlined herein can be used as a template to maximize the performance of a deformable interface intraocular lens. Translational Relevance: The article combines a multidisciplinary basic science approach from biomechanics, optical science, and ophthalmology to optimize an intraocular lens design suitable for preliminary animal trials. PMID:25938005

  14. Laser ablation and high precision patterning of biomaterials and intraocular lenses

    NASA Astrophysics Data System (ADS)

    Serafetinides, A. A.; Spyratou, E.; Makropoulou, M.

    2010-10-01

    The use of intraocular lenses (IOL) is the most promising method for restoring excellent vision in cataract surgery. In addition, multifocal intraocular lenses for good distant and near vision are investigated. Several new materials, techniques and patterns are studied for the formation and etching of intraocular lenses in order to improve their optical properties and reduce the diffractive aberrations. As pulsed laser ablation is well established as a universal tool for surface processing of organic polymer materials, this study was focused in using laser ablation with short and ultra short laser pulses for surface modification of PMMA and intraocular lenses, instead of using other conventional techniques. The main advantage of using very short laser pulses, e.g. of ns, ps or fs duration, is that heat diffusion into the polymer material is negligible. As a result high precision patterning of the sample, without thermal damage of the surroundings, becomes possible. In this study, laser ablation was performed using commercially available hydrophobic acrylic IOLs, hydrophilic acrylic IOLs, and PMMA IOLs, with various diopters. We investigated the ablation efficiency and the phenomenology of the etched patterns by testing the ablation rate, versus laser energy fluence, at several wavelengths and the surface modification with atomic force microscopy (AFM), or scanning electron microscopy (SEM). The irradiated polymers have different optical properties, at the applied wavelengths, and therefore, present different ablation behaviour and morphology of the laser ablated crater walls and surrounding surfaces. The experimental results, some theoretical assumptions for mathematical modeling of the relevant ablation mechanisms are discussed.

  15. Two cases of primary intraocular lymphoma: fine needle aspiration diagnosis and intravitreal methotrexate treatment.

    PubMed

    Zhao, Tantai; Li, Yunqin; Tang, Luosheng; Wei, Xin; Zhu, Xiaohua

    2011-02-01

    We described clinical process of two cases of intraocular lymphoma in aspects of early diagnosis by fine needle aspiration (FNA) and biopsy and treatment by intravitreal methotrexate (MTX). Two patients were suspected to have primary intraocular lymphoma (PIOL) with geographic yellow-white infiltrates and vitreous opacity. FNA confirmed malignant intraocular lymphoma in one patient and failed in the other patient due to complication of vitreous hemorrhage. Subsequent vitreous biopsy confirmed malignant intraocular lymphoma in the other patient. Both patients were treated by intravitreal methotrexate. In case 1 the tumor had complete remission and follow-up of 12 months had not found any signs of recurrence. In case 2 the patient died of brain metastasis 22 months after the ocular biopsy. Our findings demonstrate that although cytological examination of vitrectomy specimens remains the gold standard in diagnosis of PIOL, examination of FNA and biopsy increases the reliability of early diagnosing or excluding a PIOL. Individualized intravitreal methotrexate can be used to effectively treat PIOL. More effective integrated program treating primary central nervous system lymphoma/PIOL is worthy of looking forward to. PMID:21336740

  16. Clinical evaluation of clobetasone butyrate eye drops in the treatment of anterior uveitis and its effects on intraocular pressure.

    PubMed Central

    Eilon, L A; Walker, S R

    1981-01-01

    Clobetasone butyrate has been formulated as a new steroid preparation of use in ophthalmology and has been compared with prednisolone phosphate and betamethasone phosphate in the treatment of anterior uveitis. The results from 4 double-blind, between-patient studies have shown that all 3 treatments are effective in reducing the signs and symptoms of this intraocular disease. 87% of those patients receiving clobetasone butyrate had a good or satisfactory response, but no differences in therapeutic efficacy were observed between these 3 steroid treatments. Clobetasone butyrate had little effect on intraocular pressure when compared with dexamethasone or hydrocortisone, both of which cause a significant rise in intraocular pressure. PMID:7028089

  17. Nontuberculous Mycobacterial Ocular Infections: A Systematic Review of the Literature

    PubMed Central

    Kheir, Wajiha J.; Sheheitli, Huda; Abdul Fattah, Maamoun; Hamam, Rola N.

    2015-01-01

    Nontuberculous or atypical mycobacterial ocular infections have been increasing in prevalence over the past few decades. They are known to cause periocular, adnexal, ocular surface and intraocular infections and are often recalcitrant to medical therapy. These infections can potentially cause detrimental outcomes, in part due to a delay in diagnosis. We review 174 case reports and series on nontuberculous mycobacterial (NTM) ocular infections and discuss etiology, microbiology, risk factors, diagnosis, clinical presentation, and treatment of these infections. History of interventions, trauma, foreign bodies, implants, contact lenses, and steroids are linked to NTM ocular infections. Steroid use may prolong the duration of the infection and cause poorer visual outcomes. Early diagnosis and initiation of treatment with multiple antibiotics are necessary to achieve the best visual outcome. PMID:26106601

  18. Visual outcome of pars plana vitrectomy with intraocular foreign body removal through sclerocorneal tunnel and sulcus-fixated intraocular lens implantation as a single procedure, in cases of metallic intraocular foreign body with traumatic cataract

    PubMed Central

    Mahapatra, Santosh K; Rao, Nageswar G

    2010-01-01

    Aim: To evaluate visual outcome following pars plana vitrectomy (PPV) and intraocular foreign body (IOFB) removal through the sclerocorneal tunnel combined with simultaneous cataract extraction and sulcus-fixated intraocular lens (IOL) implantation as a single procedure in penetrating ocular trauma with IOFB and traumatic cataract. Materials and Methods: Eighteen cases of penetrating ocular trauma with retained IOFB and traumatic cataract who underwent PPV, IOFB body removal and cataract extraction with posterior chamber IOL (PCIOL) implantation in the same sitting, between June '04 and December '05 were retrospectively analyzed. All the foreign bodies were removed through the sclerocorneal tunnel. Result: All the 18 patients were young males, with an average follow-up period of 12 months. In 12 cases the foreign body was intravitreal and in six cases it was intraretinal but extramacular. Thirteen cases had a best corrected visual acuity ranging from 20/20 to 20/60 at their last follow-up. Five cases developed retinal detachment due to proliferative vitreoretinopathy (PVR) changes postoperatively and were subsequently managed by surgery. Conclusion: Primary IOL implantation with combined cataract and vitreo-retinal surgery is a safe option reducing the need for two separate surgeries in selected patients with retained IOFB and traumatic cataract. This combined procedure provides good visual outcome with early rehabilitation in young working patients. PMID:20195033

  19. The intraocular pressure-lowering properties of intravenous paracetamol

    PubMed Central

    van den Heever, Henning; Meyer, David

    2016-01-01

    Aim The aim of this paper was to investigate the intraocular pressure (IOP)-changing properties of a single standard dose of intravenous (IV) paracetamol and compare it to that of topical timolol, oral acetazolamide, and no treatment. Methods A prospective, randomized, investigator-blind, parallel-group study was conducted in 73 eyes of 52 subjects. Subjects received a single dose of IV paracetamol (1 g), oral acetazolamide (250 mg), topical timolol (0.5%, one drop), or no treatment. Baseline IOP was measured, and the measurement was repeated at 1, 2, 4, and 6 hours after treatment. Results Paracetamol reduced IOP from baseline by −10.8% (95% confidence interval [CI]: −4.9% to −16.8%, P=0.146) at 1 hour, −13.3% (95% CI: −8.3% to −18.4%, P=0.045) at 2 hours, −11.8% (95% CI: −5.5% to −18.4%, P=1.000) at 4 hours, and −23.9% (95% CI: −17.8% to −30.1%, P=0.006) at 6 hours after treatment. In the no-treatment group, the change was −2.9% (95% CI: +1.0% to −6.7%, P= referent) at 1 hour, −2.1% (95% CI: +2.9% to −7.2%, P= referent) at 2 hours, −7.6% (95% CI: −3.9% to −11.2%, P= referent) at 4 hours, and −6.9% (95% CI: −3.6% to −10.2%, P= referent) at 6 hours. Acetazolamide reduced IOP by −18.8% (95% CI: −12.7% to −24.8%, P=0.000) at 1 hour, −26.2% (95% CI: −18.2% to −34.2%, P=0.001) at 2 hours, −24.6% (95% CI: −16.9% to −32.3%, P=0.000) after 4 hours, and −26.9% (95% CI: −19.6% to −34.3%, P=0.000) 6 hours after treatment. Timolol reduced IOP by −31.2% (95% CI: −26.7% to −35.7%, P=0.000) at 1 hour, −27.7% (95% CI: −20.7% to −34.8%, P=0.000) at 2 hours, −28.7% (95% CI: −21.1% to −36.2%, P=0.000) at 4 hours, and −21.3% (95% CI: −13.4% to −30.0%, P=0.030) at 6 hours after treatment. The average change in IOP for the no-treatment group was −4.8% (95% CI: −2.6% to −6.9%, P= referent). It was −15.7% (95% CI: −9.3% to −22.1%, P=0.021) for paracetamol, −23.1% (95% CI: −16.4% to

  20. Intra-Ocular Pressure Measurement in a Patient with a Thin, Thick or Abnormal Cornea

    PubMed Central

    Clement, Colin I.; Parker, Douglas G.A.; Goldberg, Ivan

    2016-01-01

    Accurate measurement of intra-ocular pressure is a fundamental component of the ocular examination. The most common method of measuring IOP is by Goldmann applanation tonometry, the accuracy of which is influenced by the thickness and biomechanical properties of the cornea. Algorithms devised to correct for corneal thickness to estimate IOP oversimplify the effects of corneal biomechanics. The viscous and elastic properties of the cornea influence IOP measurements in unpredictable ways, a finding borne out in studies of patients with inherently abnormal and surgically altered corneal biomechanics. Dynamic contour tonometry, rebound tonometry and the ocular response analyzer provide useful alternatives to GAT in patients with abnormal corneas, such as those who have undergone laser vision correction or keratoplasty. This article reviews the various methods of intra-ocular pressure measurement available to the clinician and the ways in which their utility is influenced by variations in corneal thickness and biomechanics. PMID:27014386

  1. Automatic intraocular lens segmentation and detection in optical coherence tomography images.

    PubMed

    Gillner, Melanie; Eppig, Timo; Langenbucher, Achim

    2014-05-01

    We present a new algorithm for automatic segmentation and detection of an accommodative intraocular lens implanted in a biomechanical eye model. We extracted lens curvature and position. The algorithm contains denoising and fan correction by a multi-level calibration routine. The segmentation is realized by an adapted canny edge detection algorithm followed by a detection of lens surface with an automatic region of interest search to suppress non-optical surfaces like the lens haptic. The optical distortion of lens back surface is corrected by inverse raytracing. Lens geometry was extracted by a spherical fit. We implemented and demonstrated a powerful algorithm for automatic segmentation, detection and surface analysis of intraocular lenses in vitro. The achieved accuracy is within the expected range determined by previous studies. Future improvements will include the transfer to clinical anterior segment OCT devices. PMID:23928353

  2. Development of a hydrophobic polymer composition with improved biocompatibility for making foldable intraocular lenses

    NASA Astrophysics Data System (ADS)

    Haldar, R. S.; Chauhan, R.; Kapoor, K.; Niyogi, U. K.

    2014-05-01

    A hydrophobic composition for foldable intraocular lenses was developed by copolymerizing phenyl ethyl acrylate, phenyl ethyl methacrylate and butanediol diacrylate by gamma irradiation. Aqueous solution of heparin, a biocompatibilizer absorbed in hydroxyethyl methacrylate was added to the monomer mixture before irradiation to impart desired level of hydrophilicity and improved biocompatibility to the hydrophobic composition. Ketorolac tromethamine, an anti-inflammatory agent and L-glutathione, an antioxidant were added to the composition as functional additive for exhibiting improved performance while in use. Concentrations of monomers, biocompatibilizer and functional additives were optimized to develop an advanced material for foldable intraocular lenses. Transmittance, refractive index, Abbe number, hardness, tensile strength, flexibility and foldability were studied on the final composition. Scanning electron microscopic study, differential scanning calorimetric analysis, leachability and viscometry confirmed the permanent incorporation of additives into the polymer. Results of haemocompatibility, tissue implantation and cytotoxicity confirm that the biocompatibility of the base polymer was improved by incorporation of heparin.

  3. Fractured Anterior Chamber Intraocular Lens (ACIOL) Complicating Nd: YAG Laser for Peripheral Iridotomy

    PubMed Central

    Farah, Edgard; Koutsandrea, Chryssanthi; Papaefthimiou, Ioannis; Papaconstantinou, Dimitris; Georgalas, Ilias

    2014-01-01

    Laser peripheral iridotomy is the procedure of choice for the treatment of angle-closure glaucoma caused by relative or absolute pupillary block. Nd: YAG laser iridotomy has been reported to have several complications such as Iris bleeding, hyphema, transient IOP elevation, intraocular inflammation, choroidal, retinal detachment and vitreous hemorrhage. We report a case of a 74 year old lady on anticoagulant treatment who developed pupillary block and angle closure glaucoma after cataract surgery and anterior chamber intraocular lens (ACIOL) insertion complicated with intraoperative bleeding. The patient was treated with Nd: YAG laser iridotomy , however, the ACIOL was inadvertently fractured after a single shot of laser and it had to be replaced. Although the incidence is rare. Ophthalmologists and Opticians should be aware that an ACIOL may be fractured even after a single Nd:YAG laser shot and avoid to perform it close to the ACIOL. Pretreatment counseling should include this rare complication. PMID:24600484

  4. Intraocular SF6 gas applications: treatment of retinal detachments caused by holes at the posterior pole.

    PubMed

    Mester, U; Kroll, P; Völker, B; Kreissig, I

    1983-01-01

    Retinal detachments caused by holes in the posterior pole are rare among rhegmatogenous detachments, but the central position of the holes causes considerable difficulties on surgery. The use of intraocular gas bubbles affords new possibilities for the treatment of these cases. Among 1,800 consecutively treated retinal detachments, we found only 21 which were due exclusively to one or more holes at the posterior pole; of these, only 7 exhibited a hole directly in the macula. The operative treatment of these 21 detachments consisted of an intraocular gas tamponade effected through injection of SF6 combined with cryo- and laser coagulation of the periphery of the holes. Reattachment of the macula and improved visual acuity were achieved in 19 cases. The postoperative follow-up ranges from 4 to 60 months, with a mean of 29 months. PMID:6682535

  5. An aspheric intraocular telescope for age-related macular degeneration patients

    PubMed Central

    Tabernero, Juan; Qureshi, Muhammad A; Robbie, Scott J; Artal, Pablo

    2015-01-01

    We have designed an intraocular telescope for the posterior chamber of the human eye of patients with age related macular degeneration. The basic design is composed of two decentered high optical power lenses ( + 66D and −66D) inducing a 3° prismatic effect to project a magnified central field of view into a healthier location off the central fovea. Aspheric surfaces were used to ensure a compromise between good optical quality and high tolerance to the final axial position of both lenses after surgery. With this particular design, the telescope affords an extended range of depth of focus, high tolerance to different axial lengths of the eye and robustness against typical values of astigmatism and higher order aberrations. The final design has been manufactured in a foldable material and is compact enough to facilitate surgical implantation. This telescope is a simple but promising intraocular visual aid for AMD patients. PMID:25798322

  6. Reverse pupillary block associated with pigment dispersion syndrome after in-the-bag intraocular lens implantation.

    PubMed

    Itagaki, Hideo; Kunikata, Toshio; Hiratsuka, Kentaro; Saito, Junichiro; Oshika, Tetsuro

    2013-12-01

    A 61-year-old man with high myopia who had received a systemic α1A-adrenoceptor antagonist had phacoemulsification and in-the-bag intraocular lens implantation in the right eye. One day postoperatively, marked pigment dispersion in the anterior chamber, posterior bowing of the iris, and iridodonesis were noted associated with a subsequent elevation in intraocular pressure (IOP). Pharmacological pupil dilation was effective in reducing pigment dispersion and IOP, and laser peripheral iridotomy was performed to alleviate posterior bowing of the iris. We hypothesize that dynamic changes in the aqueous humor flow by cataract surgery and latent flaccidity of the iris due to the systemic α1A-adrenoceptor antagonist caused reverse pupillary block. High myopia may be another risk factor for this complication. PMID:24140374

  7. Complement Regulatory Activity of Normal Human Intraocular Fluid Is Mediated by MCP, DAF, and CD59

    PubMed Central

    Sohn, Jeong-Hyeon; Kaplan, Henry J.; Suk, Hye-Jung; Bora, Puran S.; Bora, Nalini S.

    2007-01-01

    Purpose To identify the molecules in normal human intraocular fluid (aqueous humor and vitreous) that inhibit the functional activity of the complement system. Methods Aqueous humor and vitreous were obtained from patients with noninflammatory ocular disease at the time of surgery. Samples were incubated with normal human serum (NHS), and the mixture assayed for inhibition of the classical and alternative complement pathways using standard CH50 and AH50 hemolytic assays, respectively. Both aqueous humor and vitreous were fractionated by microconcentrators and size exclusion column chromatography. The inhibitory molecules were identified by immunoblotting as well as by studying the effect of depletion of membrane cofactor protein (MCP), decay-accelerating factor (DAF), and CD59 on inhibitory activity. Results Both aqueous humor and vitreous inhibited the activity of the classical pathway (CH50). Microcentrifugation revealed the major inhibitory activity resided in the fraction with an Mr ≥ 3 kDa. Chromatography on an S-100-HR column demonstrated that the most potent inhibition was associated with the high-molecular-weight fractions (≥ 19.5 kDa). In contrast to unfractionated aqueous and vitreous, fractions with an Mr ≥ 3 kDa also had an inhibitory effect on the alternative pathway activity (AH50). The complement regulatory activity in normal human intraocular fluid was partially blocked by monoclonal antibodies against MCP, DAF, and CD59. Immunoblot analysis confirmed the presence of these three molecules in normal intraocular fluid. Conclusions Our results demonstrate that normal human intraocular fluid (aqueous humor and vitreous) contains complement inhibitory factors. Furthermore, the high-molecular-weight factors appear to be the soluble forms of MCP, DAF, and CD59. PMID:11095615

  8. An examination of the relation between intraocular pressure, fundal stretching and myopic pathology.

    PubMed

    McMonnies, Charles W

    2016-03-01

    Pathological myopia is one of the leading causes of visual impairment worldwide. Myopic development and progression is biomechanical and dominated by axial elongation. This clinical perspective examines some of the stretch-related fundal changes, which are associated with axial elongation and myopic pathology. The biomechanics of stretching of the fundus appears to depend on genetically and/or visual experience-based scleral changes, which reduce its thickness and elastic modulus so that it becomes more susceptible to the distending forces of intraocular pressure. These changes include reduced collagen synthesis, altered collagen fibres, tissue loss, altered proteoglycans and increased matrix metalloproteinase activity. Such changes are associated with reduced scleral rigidity and related increased potential to stretch in response to intraocular pressure. As axial elongation progresses, the sclera appears likely to continue to reduce in thickness and in its capacity to resist intraocular pressure, especially when pressure becomes elevated. Tessellation, lacquer cracks, myopic crescents, staphylomata, chorioretinal atrophy and retinal detachment are examined within a model for stretching of the fundus. Age, refractive error and axial length, for example, are associated with increased pathological progression. Myopic pathological progression can become dominated by vascular changes and include a greater risk of loss of acuity and blindness. Measures to control myopic pathology, which successfully slow or prevent stretching of the fundus, appear to be key factors in reducing or even avoiding permanent visual loss associated with this condition. For example, limiting axial elongation and related myopic fundus pathology by inhibiting changes which reduce the elastic modulus of scleral tissue is a desirable outcome from interventions to control myopia. Similarly, reducing exposure to the distending stress of elevated intraocular pressure appears to be a desirable form of

  9. Toric intraocular lenses: historical overview, patient selection, IOL calculation, surgical techniques, clinical outcomes, and complications.

    PubMed

    Visser, Nienke; Bauer, Noël J C; Nuijts, Rudy M M A

    2013-04-01

    We present an overview of currently available toric intraocular lenses (IOLs) and multifocal toric IOLs. Relevant patient selection criteria, IOL calculation issues, and surgical techniques for IOL implantation are discussed. Clinical outcomes including uncorrected visual acuity, residual refractive astigmatism, and spectacle independency, which have been reported for both toric IOLs and multifocal toric IOLs, are reviewed. The incidence of misalignment, the most important complication of toric IOLs, is determined. Finally, future developments in the field of toric IOLs are discussed. PMID:23522584

  10. Retropupillary Fixation of Iris-Claw Intraocular Lens for Aphakic Eyes in Children

    PubMed Central

    Brandner, Martina; Thaler-Saliba, Sarah; Plainer, Sophie; Vidic, Bertram; El-Shabrawi, Yosuf; Ardjomand, Navid

    2015-01-01

    Purpose To report outcome, complications and safety of retropupillary fixated iris-claw intraocular lenses in a pediatric population. Design Retrospective study. Patients and Methods Ten consecutive pediatric patients (15 eyes) underwent placement of retropupillary fixated iris-claw intraocular lenses between October 2007 and July 2013 at the Department of Ophthalmology, Medical University Graz and General Hospital Klagenfurt, Austria. Postoperative visual acuity and complications were analyzed. Results Median final best-corrected visual acuity improved by 0.12 logMAR from preoperative baseline. Mean postoperative spherical equivalent was -0.05 ± 1.76 D. No serious complications were observed intra- or postoperatively during the entire follow-up period of up to 40 months. One patient experienced a haptic disenclavation with IOL subluxation immediately after a car accident. Conclusion Our study demonstrates that iris-claw intraocular lens implantation behind the iris is safe in children with lack of capsular support and yields excellent visual outcome with low complication rate. PMID:26110864

  11. [Results of intraocular lens implantation in cataract complicated by medium and high myopia].

    PubMed

    Plotnikova, Iu A; Chuprov, A D; Volkov, D V

    2001-01-01

    Results of surgical treatment of cataract complicated by medium and high myopia are analyzed. The main group consisted of 90 patients (96 eyes) subjected to extracapsular cataract extraction with implantation of posterior-chamber intraocular lenses and the reference group of 128 patients in whom cataract was extracted without implantation of artificial lens. The study included creation of a mathematical model of myopic eye with estimation of pressure fluctuations in various zones of the eye, developing during transposition of the vitreous during patient's movements (head movements, jumps, falling) and the damping effect of the lens in the ocular system. It was proven by mathematical calculations that transpositions of jelly fractions of the vitreous decreased by 70% in an eye with the lens in comparison with their transposition in aphakia. Clinical studies demonstrated the efficiency of intraocular correction of aphakia in high myopia: implantation of an intraocular lens decreases the risk of detachment of the retina during the postoperative period and helps attain the desired refraction. PMID:11765458

  12. Two-photon absorption induced drug delivery from polymeric intraocular lenses

    NASA Astrophysics Data System (ADS)

    Hampp, Norbert A.; Kim, Hee-Cheol; Kreiling, Stefan; Hesse, Lutz; Greiner, Andreas

    2003-10-01

    Secondary cataracts are quite often observed after implantation of polymeric intraocular lenses. The reason for this complication is that lens epithelial cells remain in the capsular bag when the natural lens is removed. They begin proliferation and cause secondary cataracts. It is not desireable to add cell toxic agents at the time of the implantation because wound healing is negatively affected. We have developed polymeric intraocular lenses which are equipped with a drug depot which may be released non-invasively through photochemical treatment. In the example presented the drug is 5-fluoruracil (5FU) which is covalently bound to the polymer. Deliberation of 5FU from the polymer is done photochemically. Since light is transmitted permanently through the artificial intraocular lens and wearing of special glasses by the patient should be omitted conventional photochemistry is not a suitable tool for the drug release. The polymer-5FU linkage is designed in a way that it has a high two-photon absorption cross-section. Two-photon absorption is used to selectively release 5FU from the lens. The one-photon reaction is blocked since the cornea does absorb UV light. The principle shown here is not limited to 5FU but may be applied to other drugs also.

  13. Endophthalmitis following intraocular lens implantation: report of 30 cases and review of the literature.

    PubMed

    Weber, D J; Hoffman, K L; Thoft, R A; Baker, A S

    1986-01-01

    Bacterial endophthalmitis is a postoperative complication of intraocular lens implantation. A review of 30 cases showed that 77% occurred within seven days of initial cataract surgery and that all cases occurred within 32 days. Common presenting symptoms and signs included pain localized to the involved eye, decreased visual acuity, conjunctival injection, anterior chamber inflammation, hypopyon, and absent or poor red reflex. Diagnosis of an infectious etiology was made by aqueous and vitreous sampling for gram stain and culture. The commonest bacterial agents were coagulase-negative staphylococci and Staphylococcus aureus, but a wide variety of gram-negative and -positive organisms were also isolated. On the basis of this series and review of the literature, optimal treatment includes prompt diagnosis by culture and gram stain of vitreous fluid, frequent application of topical antibiotics, and administration of intraocular antibiotics. Intravenous antibiotics and vitrectomy may improve the visual outcome. Removal of the intraocular lens is unnecessary for bacteriologic cure and is not associated with improved visual outcome. PMID:3513284

  14. Blueberry Supplementation Attenuates Microglial Activation in Hippocampal Intraocular Grafts to aged hosts

    PubMed Central

    Willis, Lauren M.; Freeman, Linnea; Bickford, Paula C.; Quintero, E. Matthew; Umphlet, Claudia D.; Moore, Alfred B.; Goetzl, Laura; Granholm, Ann-Charlotte

    2010-01-01

    Transplantation of central nervous tissue has been proposed as a therapeutic intervention for age-related neurodegenerative diseases and stroke. However, survival of embryonic neuronal cells is hampered by detrimental factors in the aged host brain such as circulating inflammatory cytokines and oxidative stress. We have previously found that supplementation with 2% blueberry in the diet increases graft growth and neuronal survival in intraocular hippocampal grafts to aged hosts. In the present study we explored possible biochemical mechanisms for this increased survival, and we here report decreased microglial activation and astrogliosis in intraocular hippocampal grafts to middle-aged hosts fed a 2% blueberry diet. Markers for astrocytes and for activated microglial cells were both decreased long-term after grafting to blueberry-treated hosts compared to age-matched rats on a control diet. Similar findings were obtained in the host brain, with a reduction in OX-6 immunoreactive microglial cells in the hippocampus of those recipients treated with blueberry. In addition, immunoreactivity for the pro-inflammatory cytokine IL-6 was found to be significantly attenuated in intraocular grafts by the 2% blueberry diet. These studies demonstrate direct effects of blueberry upon microglial activation both during isolated conditions and in the aged host brain and suggest that this nutraceutical can attenuate age-induced inflammation. PMID:20014277

  15. [Intraocular Lens as a Drug Delivery Device: State of the Art and Future Perspective].

    PubMed

    Eibl-Lindner, K H; Wertheimer, C; Kampik, A

    2016-02-01

    Development of an intraocular lens (IOL) as a drug delivery device has been pursued for many years and is a promising concept in modern cataract surgery. Common postoperative conditions such as posterior capsule opacification (PCO), intraocular inflammation or the rare but severe complications of cataract surgery like endophthalmitis are potential therapeutic targets for a drug-eluting IOL. There are three techniques of pharmacological IOL modification: Firstly, surface modification of the IOL ("coating"); secondly, IOL optic modification ("soaking") and lastly, loading the IOL haptics with a slow release system. The last option does not interfere with the IOL optics at all. Therefore, a broad spectrum of pharmacological agents needs to be assessed in preclinical and clinical studies to determine which agent/IOL combination is safe and efficient. For pharmacological PCO prophylaxis, erufosine-loaded IOLs are of great clinical interest. Heparin-coated IOLs might become clinically relevant for attenuation of intraocular inflammation after cataract surgery and cefuroxime-loaded IOLs for endophthalmitis prophylaxis. PMID:26878733

  16. Intraocular lens power estimation by accurate ray tracing for eyes underwent previous refractive surgeries

    NASA Astrophysics Data System (ADS)

    Yang, Que; Wang, Shanshan; Wang, Kai; Zhang, Chunyu; Zhang, Lu; Meng, Qingyu; Zhu, Qiudong

    2015-08-01

    For normal eyes without history of any ocular surgery, traditional equations for calculating intraocular lens (IOL) power, such as SRK-T, Holladay, Higis, SRK-II, et al., all were relativley accurate. However, for eyes underwent refractive surgeries, such as LASIK, or eyes diagnosed as keratoconus, these equations may cause significant postoperative refractive error, which may cause poor satisfaction after cataract surgery. Although some methods have been carried out to solve this problem, such as Hagis-L equation[1], or using preoperative data (data before LASIK) to estimate K value[2], no precise equations were available for these eyes. Here, we introduced a novel intraocular lens power estimation method by accurate ray tracing with optical design software ZEMAX. Instead of using traditional regression formula, we adopted the exact measured corneal elevation distribution, central corneal thickness, anterior chamber depth, axial length, and estimated effective lens plane as the input parameters. The calculation of intraocular lens power for a patient with keratoconus and another LASIK postoperative patient met very well with their visual capacity after cataract surgery.

  17. Optical aberrations of intraocular lenses measured in vivo and in vitro

    NASA Astrophysics Data System (ADS)

    Barbero, Sergio; Marcos, Susana; Jiménez-Alfaro, Ignacio

    2003-10-01

    Corneal and ocular aberrations were measured in a group of eyes before and after cataract surgery with spherical intraocular lens (IOL) implantation by use of well-tested techniques developed in our laboratory. By subtraction of corneal from total aberration maps, we also estimated the optical quality of the intraocular lens in vivo. We found that aberrations in pseudophakic eyes are not significantly different from aberrations in eyes before cataract surgery or from previously reported aberrations in healthy eyes of the same age. However, aberrations in pseudophakic eyes are significantly higher than in young eyes. We found a slight increase of corneal aberrations after surgery. The aberrations of the IOL and the lack of balance of the corneal spherical aberrations by the spherical aberrations of the intraocular lens also degraded the optical quality in pseudophakic eyes. We also measured the aberrations of the IOL in vitro, using an eye cell model, and simulated the aberrations of the IOL on the basis of the IOL's physical parameters. We found a good agreement among in vivo, in vitro, and simulated measures of spherical aberration: Unlike the spherical aberration of the young crystalline lens, which tends to be negative, the spherical aberration of the IOL is positive and increases with lens power. Computer simulations and in vitro measurements show that tilts and decentrations might be contributors to the increased third-order aberrations in vivo in comparison with in vitro measurements.

  18. The influence of intraocular pressure and air jet pressure on corneal contactless tonometry tests.

    PubMed

    Simonini, Irene; Pandolfi, Anna

    2016-05-01

    The air puff is a dynamic contactless tonometer test used in ophthalmology clinical practice to assess the biomechanical properties of the human cornea and the intraocular pressure due to the filling fluids of the eye. The test is controversial, since the dynamic response of the cornea is governed by the interaction of several factors which cannot be discerned within a single measurement. In this study we describe a numerical model of the air puff tests, and perform a parametric analysis on the major action parameters (jet pressure and intraocular pressure) to assess their relevance on the mechanical response of a patient-specific cornea. The particular cornea considered here has been treated with laser reprofiling to correct myopia, and the parametric study has been conducted on both the preoperative and postoperative geometries. The material properties of the cornea have been obtained by means of an identification procedure that compares the static biomechanical response of preoperative and postoperative corneas under the physiological IOP. The parametric study on the intraocular pressure suggests that the displacement of the cornea׳s apex can be a reliable indicator for tonometry, and the one on the air jet pressure predicts the outcomes of two or more distinct measurements on the same cornea, which can be used in inverse procedures to estimate the material properties of the tissue. PMID:26282384

  19. Fine-needle aspiration biopsy and other biopsies in suspected intraocular malignant disease: a review.

    PubMed

    Eide, Nils; Walaas, Lisa

    2009-09-01

    Ocular oncologists require a strong indication for intraocular biopsy before the procedure can be performed because it carries a risk for serious eye complications and the dissemination of malignant cells. The purpose of this review is to evaluate the extent to which this restricted practice is supported by evidence from previous reports and to outline our main indications and contraindications. The different intraocular biopsy techniques in the anterior and posterior segment are discussed with a focus on our preferred method, fine-needle aspiration biopsy (FNAB). In the literature, complications are typically under-reported, which reduces the possibilities of evaluating the risks correctly and of making fair comparisons with other biopsy methods. In FNAB, the exact placement of the needle is critical, as is an accurate assessment of the size of the lesion. Fine-needle aspiration biopsy is usually not a reliable diagnostic tool in lesions < 2 mm in thickness. It is very advantageous to have a cytopathologist present in the operating theatre or close by. This ensures adequate sampling and encourages repeated biopsy attempts if necessary. This approach reduces false negative results to < 3%. Adjunct immunocytochemistry is documented to increase specificity and is essential for diagnosis and management in about 10% of cases. In some rare pathological processes the diagnosis depends ultimately on the identification of specific cell markers. An accurate diagnosis may have a decisive influence on prognosis. The cytogenetic prognostications made possible after FNAB are reliable. Biopsy by FNA has a low complication rate. The calculated risk for retinal detachment is < 4%. Intraocular haemorrhage is frequently observed, but clears spontaneously in nearly all cases. Only a single case of epibulbar seeding of malignant cells at the scleral pars plana puncture site of transvitreal FNAB has been documented. Endophthalmitis has been reported and adequate standard preoperative

  20. Central line infections - hospitals

    MedlinePlus

    ... infection; CVC - infection; Central venous device - infection; Infection control - central line infection; Nosocomial infection - central line infection; Hospital acquired infection - central line infection; Patient safety - central ...

  1. Prostaglandin E2-Glyceryl Ester: In Vivo Evidence for a Distinct Pharmacological Identity from Intraocular Pressure Studies.

    PubMed

    Woodward, David F; Poloso, Neil J; Wang, Jenny W

    2016-08-01

    Prostaglandin E2 (PGE2)-2-glyceryl ester is a cyclo-oxygenase 2 product of the endocannabinoid 2-arachidonyl glycerol. It is claimed as pharmacologically novel, but this is complicated by rapid and irreversible isomerization to the 1(3) ester. For ocular studies, enzymatic hydrolysis of the ester moiety creates an additional complication. PG-glyceryl esters were stabilized to isomerization and hydrolysis by replacing the noncarbonyl O with NH, to form the serinolamide and propanediolamide as stable analogs of PG-2-glyceryl and PG-2-1(3) glyceryl esters, respectively. Intraocular pressure was measured in conscious dogs and conscious laser-induced ocular hypertensive monkeys. Pharmacological studies involved stable transfectants for each of the human recombinant prostanoid receptors and the isolated feline iris for prostamide activity. PGE2-serinolamide and PGE2- propanediolamide were essentially inactive at all receptors except the EP3 receptor (EC50, ∼500 nM). This obliged elucidation of EP3 receptor involvement in the intraocular pressure response to these PGE2-glycyerl ester analogs. Since the EP3 receptor agonists sulprostone and GR 63799 did not lower monkey intraocular pressure, a role for EP3 receptors in mediating the effects of PGE2-serinolamide and PGE2-propanediolamide is not indicated. PGE2-glyceryl ester (0.01% and 0.1%) substantially lowered intraocular pressure in monkeys. PGE2-propanediolamide was more efficacious than PGE2-serinolamide in lowering intraocular pressure in monkey eyes, but both appeared equieffective in dog eyes. PGE2-serinolamide dose-dependently (0.01- 0.1%) lowered intraocular pressure in both species, but PGF2 α-serinolamide was inactive. In conclusion, stable PGE2-glyceryl ester analogs lowered intraocular pressure. These findings are consistent with the presence of a PGE2-glyceryl ester-specific recognition site in the eye. PMID:27217589

  2. Intraocular lymphoma in Korea: the Consortium for Improving Survival of Lymphoma (CISL) study

    PubMed Central

    Lee, Seul; Kim, Moon Jin; Kim, Jin Seok; Kim, Seok Jin; Kwon, Yoon Hyung; Chung, In Young; Kang, Jung Hun; Yang, Deok-Hwan; Kang, Hye Jin; Yoon, Dok Hyun; Kim, Won Seog; Kim, Hyo-Jin

    2015-01-01

    Background Intraocular lymphoma (IOL) is a rare malignant lymphoma that most closely resembles a diffuse large B-cell lymphoma, and it is a subtype of primary central nervous system lymphoma (PCNSL). IOL is located inside the eye in the retina, uvea, and/or optic nerve. We retrospectively analyzed IOL patient data to identify treatment patterns and survival rates in Korea. Methods Cytological confirmation for a diagnosis of IOL was performed for all patients. The clinical data collected from medical records included Ann Arbor stage, International Prognostic Index, performance status, date of diagnosis, treatment modality and response, date of relapse, and date of last follow-up. Results Twenty patients who were diagnosed with IOL, between December 2007 and June 2014 at multiple centers in Korea, were included in the analysis. Four patients were diagnosed with IOL alone, not involving the CNS. Two patients with isolated IOL later developed PCNSL. Nine patients developed CNS lesions before the onset of ocular lymphoma. Five patients had simultaneous onset in the eye and CNS. Twelve patients were treated by intravitreal injection of methotrexate for IOL. The median progression-free survival (PFS) for patients was 19.7 months (95% CI, 8.7-30.7 mo). The estimated 3-year overall survival (OS) for all patients was 75.1%. Conclusion Treatment for IOL patients included radiotherapy and intraocular chemotherapy. IOL patients showed favorable PFS and OS. These patients would require long-term follow-up to identify relapse and adverse effects of radiotherapy or intraocular chemotherapy. PMID:26770952

  3. Evaluation of a new soft tipped injector for the implantation of foldable intraocular lenses

    PubMed Central

    Kleinmann, Guy; Apple, David J

    2007-01-01

    Aim To evaluate the R‐INJ‐04 soft‐tipped injector, a new injector with an integral round nozzle manufactured by Rayner Intraocular Lenses, England. Methods 16 Rayner C‐flex intraocular lenses (IOLs; Rayner Intraocular lenses, England) ranging between +10 and +30 D (2 for each power) were tested. An ophthalmic viscoelastic device (Healon, AMO, Santa Ana, California, USA) was applied to the injectors. The IOLs were loaded according to the company injector's instructions for use and were injected into a Petri dish. After the injection, all the IOLs and nozzles were evaluated by gross (macroscopic) and microscopic analyses and photographed under a light microscope. One lens of each power and the cartridge used for the implantation were then sent for further analysis by scanning electron microscopy (SEM). The rest of the IOLs were tested for power and modulation transfer function (MTF). Results All the injections were successful. No damage to the IOLs or to the injectors was found by gross examination, light microscopy and SEM. No deposits were found on the IOL optical surfaces or haptics. Power and MTF analysis showed a close match with the original measurements. Conclusion Our results suggest that the R‐INJ‐04 soft‐tipped injector is safe for the implantation of the C‐flex IOL with power range from 10 to 30 D. No structural damage to the IOLs or to the injectors was found, and the lens power and light transmission properties were not damaged in any way by the injection process. PMID:17135340

  4. [Reliable UV-light protection in intraocular lenses--scientific rationale and quality requirements].

    PubMed

    Augustin, A J

    2014-09-01

    Since the late 1980s implantation of UV-blocker intraocular lenses during cataract surgery has become an internationally accepted standard. Last year the Kassenärztliche Vereinigung Bayern (KVB) and statutory health insurance organisations proposed for the first time quality criteria for intraocular lenses (IOL), thereby including exact parameters for the amount of UV light transmission (≤10% at 400 nm). Since then, the discussion has been raised again as to what extent IOLs should filter or block UV light. In this article, exact definitions of spectral subbands within the optical radiation band are given. Today, 400 nm is the internationally accepted standard to distinguish UV light and visible light. Moreover, exposure of the eye to UV radiation is described as well as mechanisms of photooxidative damage to the retina. Comprehensive laboratory and animal experimental studies show that light of short wave lengths, i.e., above all UV light but also blue light, may induce photochemical damage to the retina. Primary sites of such damage are both the outer segments of the photoreceptors and the retinal pigment epithelium (RPE). Physiological protective mechanisms of the eye, such as filtering properties of different ocular media are described in detail. Cornea, aqueous and vitreous absorb UV radiation below 300 nm, while the natural adult lens absorbs UV radiation between 300 and 400 nm. This protection is lost when the lens is removed by cataract surgery and thus should be restored. UV light does not contribute to vision but damages retinal structures. Therefore, UV-blocking intraocular lenses with a 10% cut-off near 400 nm should be implanted during cataract surgery. This ensures sufficient retinal protection after surgery. These theoretical considerations are supported by results from animal and clinical studies. PMID:24992237

  5. Intra- and Intersession Repeatability of an Optical Quality and Intraocular Scattering Measurement System in Children

    PubMed Central

    Shen, Yang; Gao, Jian; Mo, Xiaofen; Zhou, Xingtao

    2015-01-01

    Purpose To evaluate intra- and intersession repeatability of objective optical quality and intraocular scattering measurements with a double-pass system in children. Methods Forty-two eyes of 42 children were included in the study. An optical quality analysis system (OQAS) was used to measure optical quality parameters, including modulation transfer function cutoff frequency (MTFcutoff), Strehl ratio (SR), OQAS values (OV) at 3 different contrasts and objective scatter index (OSI). Three measurement sessions with 10-min intervals were operated by the same technician, and in each session four consecutive measurements were obtained. Results Mean values for MTFcutoff, SR and OSI were 46.85 ± 7.45cpd, 0.27 ± 0.06 and 0.34 ± 0.22 respectively. 1) The intraclass correlation coefficients were ranged from 0.89 to 0.97 and coefficients of variation from 0.06 to 0.16 for all the parameters in the first session; the relative repeatability were 11.1% (MTFcutoff), 22.5% (SR), 10.9% (OV100%), 16.6% (OV2%), 22.4% (OV9%) and 56.3% (OSI). Similar results were found in the second and third sessions. 2) Bland-Altman analysis showed that narrow 95% confidence intervals (compared between the first and second sessions) ranged from -5.42 to 5.28 (MTFcutoff), -0.05 to 0.07 (SR), -0.18 to 0.18 (OV100%), -0.26 to 0.29 (OV20%), -0.33 to 0.39 (OV9%) and -0.11 to 0.09 (OSI); the comparison between any two of the three sessions showed similar results. Conclusion Measurements of optical quality and intraocular scattering in children by the double-pass system showed good intra- and intersession repeatability. Retinal image quality is high and intraocular scattering is low in children. PMID:26536120

  6. Time Course of Optical Quality and Intraocular Scattering after Refractive Lenticule Extraction

    PubMed Central

    Kamiya, Kazutaka; Shimizu, Kimiya; Igarashi, Akihito; Kobashi, Hidenaga

    2013-01-01

    Purpose To assess the time course of optical quality and intraocular scattering in relation to visual acuity after femtosecond lenticule extraction (FLEx) for the correction of myopia. Methods This study evaluated 36 eyes of 36 patients with spherical equivalents of −4.38±1.53 D [mean ± standard deviation] who underwent FLEx. Before surgery, and 1 week and 1, 3 and 6 months after surgery, we assessed the modulation transfer function (MTF) cutoff frequency, Strehl ratio, objective scattering index (OSI), and OQAS values (OVs), using a double-pass instrument. We also investigated the relationship of the OSI with corrected distance visual acuity (CDVA) preoperatively and postoperatively. Results The mean changes in MTF cutoff frequency, Strehl ratio, OSI, OV100%, OV20%, and OV9% preoperatively and 6 months postoperatively were −5.51±15.01, −0.03±0.07, 0.35±0.83, −0.17±0.48, −0.14±0.38, and −0.09±0.22, respectively. We found no significant preoperative correlation between the OSI and logMAR CDVA (Spearman rank correlation coefficient r = 0.068, p = 0.69), and modest, but significant correlations 1 week and 1, 3, and 6 months postoperatively (r = 0.572, r = 0.562, r = 0.542, r = 0.540, p<0.001, respectively). Conclusions FLEx induced a transient decrease in optical quality in association with an increase in intraocular scattering in the early postoperative period, possibly due to mild interface haze formation, but gradually recovered with time. It is suggested that this transient degradation in optical quality related to an increase in the intraocular scattering may result in a slight delay of CDVA recovery in the early postoperative period. PMID:24146917

  7. The dynamics and location of axonal transport blockade by acute intraocular pressure elevation in primate optic nerve.

    PubMed

    Quigley, H; Anderson, D R

    1976-08-01

    Axonal transport in primate optic nerve axons was studied by autoradiography, scintillation counting, and electron microscopy under conditions of short-term intraocular pressure elevation. With elevation of intraocular pressure to 30 mm. Hg below mean arterial blood pressure, blockage of transport was detected within 2 hours by autoradiography and within 1 hour by electron microscopy. The earliest buildup of radioactively labeled protein and ultrastructurally visible cellular organelles was within the scleral lamina cribrosa. The degree of blockage, judged by amount of label buildup, increased with time. Some transported material traversed the lamina cribrosa despite pressure elevation at the level tested. Reversal of transport blockade occurred rapidly after normalization of intraocular pressure. PMID:60300

  8. Refractive errors induced by displacement of intraocular lenses within the pseudophakic eye.

    PubMed

    Atchison, D A

    1989-03-01

    Simple methods were developed to estimate refractive errors when intraocular lenses are not fitted optimally within pseudophakic eyes. The accuracy of these methods was determined by comparing results obtained with them to results obtained by raytracing through a model eye. Accuracy was good for longitudinal displacement and tilting, and reasonable for transverse displacement. Refractive errors are related linearly to the magnitude of the longitudinal displacement, and are related to the square of the magnitude of tilt or transverse displacement. The refractive error upon transverse displacement is quadratically dependent upon lens shape. PMID:2717142

  9. Comparison of retinal image quality with spherical and customized aspheric intraocular lenses

    PubMed Central

    Guo, Huanqing; Goncharov, Alexander V.; Dainty, Chris

    2012-01-01

    We hypothesize that an intraocular lens (IOL) with higher-order aspheric surfaces customized for an individual eye provides improved retinal image quality, despite the misalignments that accompany cataract surgery. To test this hypothesis, ray-tracing eye models were used to investigate 10 designs of mono-focal single lens IOLs with rotationally symmetric spherical, aspheric, and customized surfaces. Retinal image quality of pseudo-phakic eyes using these IOLs together with individual variations in ocular and IOL parameters, are evaluated using a Monte Carlo analysis. We conclude that customized lenses should give improved retinal image quality despite the random errors resulting from IOL insertion. PMID:22574257

  10. Visual performance after the implantation of a new trifocal intraocular lens

    PubMed Central

    Vryghem, Jérôme C; Heireman, Steven

    2013-01-01

    Purpose To evaluate the subjective and objective visual results after the implantation of a new trifocal diffractive intraocular lens. Methods A new trifocal diffractive intraocular lens was designed combining two superimposed diffractive profiles: one with +1.75 diopters (D) addition for intermediate vision and the other with +3.50 D addition for near vision. Fifty eyes of 25 patients that were operated on by one surgeon are included in this study. The uncorrected and best distance-corrected monocular and binocular, near, intermediate, and distance visual acuities, contrast sensitivity, and defocus curves were measured 6 months postoperatively. In addition to the standard clinical follow-up, a questionnaire evaluating individual satisfaction and quality of life was submitted to the patients. Results The mean age of patients at the time of surgery was 70 ± 10 years. The mean uncorrected and corrected monocular distance visual acuity (VA) were LogMAR 0.06 ± 0.10 and LogMAR 0.00 ± 0.08, respectively. The outcomes for the binocular uncorrected distance visual acuity were almost the same (LogMAR −0.04 ± 0.09). LogMAR −010 ± 0.15 and 0.02 ± 0.06 were measured for the binocular uncorrected intermediate and near VA, respectively. The distance-corrected visual acuity was maintained in mesopic conditions. The contrast sensitivity was similar to that obtained after implantation of a bifocal intraocular lens and did not decrease in mesopic conditions. The binocular defocus curve confirms good VA even in the intermediate distance range, with a moderate decrease of less than LogMAR 0.2 at −1.5 D, with respect to the best distance VA at 0 D defocus. Patient satisfaction was high. No discrepancy between the objective and subjective outcomes was evidenced. Conclusion The introduction of a third focus in diffractive multifocal intraocular lenses improves the intermediate vision with minimal visual discomfort for the patient. PMID:24124348

  11. Decompensation of ocular torsion following malrotation of a toric intraocular lens.

    PubMed

    Ramskold, Louise; Lodhia, Vaishali; Jones, Alistair; Jain, Saurabh

    2015-12-01

    Toric intraocular lenses (IOLs) are being increasingly used to correct corneal astigmatism in cataract surgery. A quarter of patients that undergo cataract surgery may benefit from a toric rather than a spherical IOL. However, these implants must be positioned accurately, because postoperative rotation of the toric IOL can have clinically significant consequences. We present the first documented case of a 78-year-old woman who presented with diplopia as a result of exacerbation of a preexisting torsion following toric lens implantation. PMID:26691041

  12. Ultraviolet or blue-filtering intraocular lenses: what is the evidence?

    PubMed

    Downes, S M

    2016-02-01

    Cataract surgery was revolutionised by the introduction of modern intraocular lenses in the late 1940's. By the late 1960's to 1970's evidence had emerged that short-wavelength light caused phototoxicity at the retina and retinal pigment epithelium. By the early 1980's ultraviolet filters had been incorporated into intraocular lenses. This caused intense controversy, as there was concern that the UV-filtering chromophore might leach out into the eye causing toxicity. With the arrival of blue-filtering intraocular lenses (BFIOLs) in 1990's, a further debate was ignited as to their safety and potential disadvantages. Selecting the optimal performing intraocular lens to obtain the best visual performance with the fewest potential drawbacks has become complex and challenging for cataract surgeons and their patients with the wide choice of lenses available. Choosing a personalised lens to address astigmatism, presbyopia, spherical aberration, chromatic aberration, and potentially to shield the retina from short-wavelength light is now possible. The potential benefits and possible side effects of these different innovations emphasise the importance of assessing the evidence for their clinical utility, allowing the surgeon and the patient to weigh-up the risk benefit ratio and make an informed decision. The BFIOLs were developed to reduce cyanopsia, address chromatic aberration, and improve contrast sensitivity in different lighting conditions, as well as to prevent short-wavelength light reaching the retina thus potentially reducing the risk of developing age-related macular degeneration. Further design development of the BFIOLs was to mimic the natural crystalline lens absorption and transmittance properties in adulthood. Multiple publications have reported on the potential benefits and pitfalls of implanting a blue-filtering lens. The potential disadvantages raised in the literature over the last 25 years since their introduction, regarding compromise of visual

  13. INTRAOCULAR SILICONE BALL IMPLANTATION AFTER EVISCERATION IN A SLOW LORIS (NYCTICEBUS COUCANG).

    PubMed

    Kim, Jury; Kim, Young-Jun; Ji, Dong-Beom; Kim, Min-Su

    2016-06-01

    A slow loris, Nycticebus coucang , was brought to Ji Dong Beom Animal Hospital from the National Institute of Ecology due to globe enlargement and frequent blepharospasm of the right eye. Ophthalmic diagnoses included glaucoma with posterior lens luxation and cataract. Because this animal was on exhibition at the National Institute of Ecology, preservation of the eyeball by intraocular silicone implantation following evisceration rather than enucleation was selected. Before the surgery, examination of the normal left eye was performed using Retcam and spectral domain optical coherence tomography. Three months later, the globe size was almost the same as the left eye; however, corneal edema remained. PMID:27468037

  14. Using the Electroretinogram to Understand How Intraocular Pressure Elevation Affects the Rat Retina

    PubMed Central

    Bui, Bang V.; He, Zheng; Vingrys, Algis J.; Nguyen, Christine T. O.; Wong, Vickie H. Y.; Fortune, Brad

    2013-01-01

    Intraocular pressure (IOP) elevation is a key risk factor for glaucoma. Our understanding of the effect that IOP elevation has on the eye has been greatly enhanced by the application of the electroretinogram (ERG). In this paper, we describe how the ERG in the rodent eye is affected by changes in IOP magnitude, duration, and number of spikes. We consider how the variables of blood pressure and age can modify the effect of IOP elevation on the ERG. Finally, we contrast the effects that acute and chronic IOP elevation can have on the rodent ERG. PMID:23431417

  15. Retropupillary iris-claw intraocular lens in ectopia lentis in Marfan syndrome

    PubMed Central

    Faria, Mun Yueh; Ferreira, Nuno; Neto, Eliana

    2016-01-01

    Objective To report visual outcomes, complication rate, and safety of retropupillary iris-claw intraocular lens (ICIOL) in ectopia lentis in Marfan syndrome (MFS). Design Retrospective study. Methods Six eyes of three MFS patients with ectopia lentis underwent surgery for subluxation lens and retropupillary ICIOL implantation from October 2014 to October 2015 at the Department of Ophthalmology, Santa Maria Hospital in Lisbon, Portugal. Demographics, preoperative and postoperative best-corrected visual acuity (BCVA), and intraocular pressure were evaluated. Endothelium cell count was assessed using specular microscopy; anterior chamber depth was measured using Pentacam postoperatively; and intraocular lens position was viewed by ultrasound biomicroscopy. All patients were female; mean age was 20±14.264 years (range: 7–38 years). Results The average follow-up period was 6.66 months (range: 4–16 months). Preoperative BCVA was 0.568±0.149 logMAR units, and postoperative BCVA was 0.066±0.121 logMAR units. The mean BCVA gain was −0.502±0.221 on the logMAR scale. Postoperative average astigmatism and intraocular pressure were 1.292±0.697 mmHg (range: 0.5–2.25 mmHg) and 16 mmHg (range: 12–18 mmHg), respectively. The average endothelial cell density decreased from 3,121±178 cells/mm2 before surgery to 2,835±533 cells/mm2 after surgery (measured at last follow-up visit) and in the last follow-up, representing an average endothelial cell loss of 9.16%. Mean anterior chamber depth was 4.01 mm (±0.77 mm), as measured by Pentacam. No complications were found intra- or postoperatively in any of the six studied eyes. Conclusion Retropupillary ICIOL implantation is a safe and effective procedure in the treatment of aphakia in MFS eyes, without capsular support after surgery for ectopia lens. The six eyes that underwent lensectomy and retropupillary ICIOL implantation have had excellent visual outcomes with no complications so far. PMID:27382335

  16. Delayed microhyphaema with intraocular lenses: a retrospective study of eight patients.

    PubMed Central

    Butler, L; Roper-Hall, M J

    1989-01-01

    Eight patients with delayed microhyphaema were identified from a computer data base of 1209 patients who had had cataract extraction with Binkhorst 4-loop intraocular lens insertion. Five cases were recurrent. The cases were examined to try and identify an underlying cause. No single cause was identified, but trauma, hypertension, and oral anticoagulants were found to be associated. Some episodes were asymptomatic. The wide variety of surgical technique and style of lens with which this complication has been reported implies multiple causative factors. The source of the bleeding and its management are discussed. PMID:2930755

  17. Design, synthesis, and evaluation of NO-donor containing carbonic anhydrase inhibitors to lower intraocular pressure.

    PubMed

    Huang, Qinhua; Rui, Eugene Y; Cobbs, Morena; Dinh, Dac M; Gukasyan, Hovhannes J; Lafontaine, Jennifer A; Mehta, Saurabh; Patterson, Brian D; Rewolinski, David A; Richardson, Paul F; Edwards, Martin P

    2015-03-26

    The antiglaucoma drugs dorzolamide (1) and brinzolamide (2) lower intraocular pressure (IOP) by inhibiting the carbonic anhydrase (CA) enzyme to reduce aqueous humor production. The introduction of a nitric oxide (NO) donor into the alkyl side chain of dorzolamide (1) and brinzolamide (2) has led to the discovery of NO-dorzolamide 3a and NO-brinzolamide 4a, which could lower IOP through two mechanisms: CA inhibition to decrease aqueous humor secretion (reduce inflow) and NO release to increase aqueous humor drainage (increase outflow). Compounds 3a and 4a have shown improved efficacy of lowering IOP in both rabbits and monkeys compared to brinzolamide (2). PMID:25728019

  18. A slide rule for calculating the power of an intraocular lens.

    PubMed

    Wang, G J; Pomerantzeff, O; Miao, T Y

    1983-01-01

    We have designed a slide rule to calculate the emmetropizing and iseikonizing power of an intraocular lens (IOL). Like the dial biometer currently used for these calculations, the slide rule is inexpensive, easy to use, simple, and a compact pocket size. It can, however, also be used to calculate postoperative refractive error, corneal power when various keratometers are used, and conversion of refractive correction at the spectacle frame to that at the cornea, or vice versa. All the calculated data are within the accuracy suitable for clinical work. PMID:6630016

  19. [State-of-the-art cataract surgery and intraocular optical correction].

    PubMed

    Maliugin, B É

    2014-01-01

    The paper provides current knowledge on cataract epidemiology worldwide and in the Russian Federation, including issues of cataractogenesis and prevention. An overview of medical equipment for preoperative and intraoperative diagnostics is provided. Key aspects of the conventional ultrasonic phacoemulsification method as well as the most marked trends in correction of aphakia with intraocular lenses and in design of the latter are presented. Major laser-assisted techniques, including those that imply the use of femtosecond laser systems, and results that they yielded to date are discussed in detail. PMID:25715557

  20. Simple technique to measure toric intraocular lens alignment and stability using a smartphone.

    PubMed

    Teichman, Joshua C; Baig, Kashif; Ahmed, Iqbal Ike K

    2014-12-01

    Toric intraocular lenses (IOLs) are commonly implanted to correct corneal astigmatism at the time of cataract surgery. Their use requires preoperative calculation of the axis of implantation and postoperative measurement to determine whether the IOL has been implanted with the proper orientation. Moreover, toric IOL alignment stability over time is important for the patient and for the longitudinal evaluation of toric IOLs. We present a simple, inexpensive, and precise method to measure the toric IOL axis using a camera-enabled cellular phone (iPhone 5S) and computer software (ImageJ). PMID:25316617

  1. A time-delay calibrated method for cornea hysteresis and intraocular pressure measurement

    NASA Astrophysics Data System (ADS)

    Wang, Kuo-Jen; Tsai, Che-Liang; Wang, Wai; Hsu, Long; Hsu, Ken-Yuh

    2016-04-01

    The presence of cornea hysteresis (CH) in characterizing the intraocular pressure (IOP) of a human eye deteriorates the accuracy of IOP. To suppress CH, the pressure gauge of a tonometer must be located as close as possible to the cornea. However, this arrangement is unpractical because appropriate working distance to the cornea is required. In this paper, a time-delay calibrated (TDC) method is proposed to counteract the undesired effect of CH in characterizing the IOP. Employing this TDC method, the CH approaches to zero for most eyes measured.

  2. Measurement of intraocular distances in human eyes by using Fourier domain low-coherence interferometry

    NASA Astrophysics Data System (ADS)

    Feng, Liang; Zhu, Lida; Li, Qinghua; Ma, Zhenhe; Wang, Bo; Wang, Yi

    2016-03-01

    We introduce a system for rapidly measuring the intraocular distances of human eyes in vivo with high sensitivity by using Fourier domain low-coherence interferometry. The system mainly consisting of a rapid focus displacement unit and a reference arm which has a variable optical path length. This system is capable of providing a complete biometrical assessment of a human eye in a single measurement procedure, including cornea thickness, anterior chamber depth, lens thickness, and axial length. The system is experimentally verified by measuring the four parameters of a human eye in vivo.

  3. Comparison of the efficiency, MTF and chromatic properties of four diffractive bifocal intraocular lens designs.

    PubMed

    Castignoles, Fannie; Flury, Manuel; Lepine, Thierry

    2010-03-01

    The aim of this paper is to compare the properties of four different profiles which can be used as multifocal intraocular lens. The Hankel transform based on the theory of scalar diffraction is applied to a binary profile, a parabolic one, a parabolic profile with holes, and finally a sinusoidal one. This enables to study the various distributions of the diffractive efficiencies and the axial chromatism. The image quality is evaluated by means of simulations of the MTFs with Zemax. Finally we propose a new way to graphically synthesize all the properties of these lenses, using a radar graph. PMID:20389537

  4. Initial clinical experience with the picosecond Nd:YLF laser for intraocular therapeutic applications

    PubMed Central

    Geerling, G.; Roider, J.; Schmidt-Erfurt, U.; Nahen, K.; El-Hifnawi, E.; Laqua, H.; Vogel, A.

    1998-01-01

    AIMS/BACKGROUND—Compared with nanosecond (ns) pulses of conventional Nd-YAG lasers, picosecond (ps) laser pulses allow intraocular surgery at considerably lower pulse energy. The authors report initial clinical experiences using a Nd:YLF ps laser for the treatment of various indications for photodisruption.
METHODS—A Nd:YLF laser system (ISL 2001, wavelength 1053 nm) was used to apply pulse series of 100-400 µJ single pulse energy at a repetition rate of 0.12-1.0 kHz. Computer controlled patterns were used to perform iridectomies (n=53), capsulotomies (n=9), synechiolysis (n=3), and pupilloplasties (n=2). Other procedures were vitreoretinal strand incision (n=2) and peripheral retinotomy (n=1). For comparison, 10 capsulotomies and 20 iridotomies were performed with a Nd:YAG ns laser. The ps laser cut of an anterior capsule was assessed by scanning electron microscopy (SEM).
RESULTS—Open, well defined iridectomies (mean total energy 4028 mJ, mean diameter 724 µm) were achieved at first attempt in 92% of the cases. In 64% an iris bleeding and in 21% an IOP increase of >10 mm Hg occurred. All capsulotomies were performed successfully (mean energy 690 mJ/mm cutting length) but with a high incidence of intraocular lens damage. The attempted vitreoretinal applications remained unsuccessful as a result of optical aberrations of the eye and contact lens. Although ps laser capsulotomies and iridectomies required much higher total energy than ns procedures, the resulting tissue effects of the ps pulses were more clearly defined. SEM examination of a ps incision of the anterior lens capsule demonstrated, nevertheless, that the cut was more irregular than the edge of a continuous curvilinear capsulorhexis.
CONCLUSION—Series of ps pulses applied in computer controlled patterns can be used effectively for laser surgery in the anterior segment and are considerably less disruptive than ns pulses. The ps laser is well suited for laser iridectomies while the

  5. Influence of various anesthetic drugs on the intraocular pressure of cats.

    PubMed

    Hahnenberger, R W

    1976-04-14

    Cats with one normal eye and one eye with experimental glaucoma were trained to tolerate tonometry while conscious. They were then given the general anesthetic agents pentobarbital, ketamine, and CI-744 in the lowest and twice the lowest dosages which permitted tonometry in untrained cats. Pentobarbital lowered intraocular pressure (IOP) by 20-50%. Ketamine raised IOP by about 10%. CI-744 had essentially no effect on IOP. The two conpoments of CI-744, tiletamine (CI-634) and zolazepam (CI-716) were given individually in the doses in which they had been given as part of CI-744. Tiletamine had no effect on IOP, while zolazepam lowered IOP by about 10%. PMID:1083696

  6. Meningococcal Infections

    MedlinePlus

    ... are a type of bacteria that cause serious infections. The most common infection is meningitis, which is an inflammation of the ... also cause other problems, including a serious bloodstream infection called sepsis. Meningococcal infections can spread from person ...

  7. Comparison of pseudophakic retinal straylight in spherical/aspherical and hydrophobic/hydrophilic intraocular lens

    PubMed Central

    Tang, Yong; Song, Hui; Chen, Jing; Tang, Xin

    2015-01-01

    AIM To study the potential reasons of increased straylight in pseudophakic eyes. METHODS Cross-sectional study. Seventy patients diagnosed as bilateral age-related cataract and implanted with Tecnis ZA9003, Sensar AR40e, SA60AT, XLSTABI ZO or Akeros AO intraocular lens (IOL) were enrolled in this research. Straylight was measured by a C-Quant straylight meter three to four weeks postoperatively. Five different modalities of IOL, including spherical/aspherical optics and hydrophobic/hydrophilic material were tested in this study. Normal as well as dilated pupils were used. The main outcome variable for straylight measurement was the logarithmic straylight parameter, log(s). RESULTS The straylight parameter increased significantly after pupil dilation (P<0.05). Straylight of aspherical IOL was significantly higher after pupil dilation (P<0.05) compared to spherical IOL. In normal pupil, straylight of hydrophobic IOL was significant higher when compared with hydrophilic IOL (P<0.05). CONCLUSION Straylight and visual acuity stand for the different aspects of visual function. Several factors including pupil diameter, optic material, aspherical design of IOL influence intraocular light scattering in pseudophakic eyes. Further investigation was needed to study the impact of optic material and optic surface design on pseudophakic straylight. PMID:26682163

  8. A Case of Intraocular Erosion and Intrusion by an Arruga Suture

    PubMed Central

    Kitagaki, Takakuni; Morishita, Seita; Kohmoto, Ryohsuke; Fukumoto, Masanori; Suzuki, Hiroyuki; Sato, Takaki; Kobayashi, Takatoshi; Kida, Teruyo; Nakajima, Masayuki; Ikeda, Tsunehiko

    2016-01-01

    Purpose To report a case of intraocular erosion and intrusion by an Arruga suture. Case Report This study involved a 62-year-old male who had undergone scleral buckling surgery 40 or more years ago at another hospital for rhegmatogenous retinal detachment, as well as trabeculectomy 20 years ago for primary open-angle glaucoma, in his left eye at the same hospital. However, he recently became aware of blurred vision in that eye. Upon examination, iritis was observed in the anterior portion of his left eye, as well as a great number of pigment cell keratoprecipitates on the posterior surface of the cornea. In the ocular fundus, extensive atrophy of the retinal pigment epithelium and partial hyperpigmentation was observed, accompanied by subretinal strands, yet the retina remained attached. Around the entire peripheral area of the retina we observed a ring-shaped protrusion, but we also saw a shiny, filamentous material in the vitreous cavity that penetrated the sclera and choroid, completely extending from the 4- to 8-o'clock position of the scleral buckle protrusion. To treat the iritis in the patient's left eye, we began to administrate low-concentration steroid eye drops, after which the inflammation disappeared. Conclusion In this study, we experienced a case of intraocular erosion and intrusion by an Arruga suture, and opted to treat the patient with steroid eye drops and conservative follow-up observations unless retinal redetachment and/or vitreous hemorrhage occurs. PMID:27099609

  9. The effects of intravenous alfaxalone with and without premedication on intraocular pressure in healthy dogs.

    PubMed

    Bauer, Bianca S; Ambros, Barbara

    2016-04-01

    The objective of this study was to investigate the effects of intravenous alfaxalone with and without premedication on intraocular pressure (IOP) in healthy dogs. Thirty-three dogs were randomized to receive 1 of 3 treatments: acepromazine [0.03 mg/kg body weight (BW)] with butorphanol (0.2 mg/kg BW) intramuscularly (IM), followed by intravenous (IV) alfaxalone (1.5 mg/kg BW); dexmedetomidine (0.002 mg/kg BW) with hydromorphone (0.1 mg/kg BW) IM, followed by alfaxalone (1 mg/kg BW) IV; and saline 0.9% (0.02 mL/kg BW) IM, followed by alfaxalone (3 mg/kg BW) IV. Intraocular pressure (IOP) was measured at baseline, 15 min, and 30 min after premedication, after pre-oxygenation, after administration of alfaxalone, and after intubation. After induction and after intubation, the IOP was significantly increased in all groups compared to baseline. While premedication with acepromazine/butorphanol or dexmedetomidine/hydromorphone did not cause a significant increase in IOP, the risk of vomiting and the associated peak in IOP after dexmedetomidine/hydromorphone should be considered when selecting an anesthetic protocol for dogs with poor tolerance for transient increases in IOP. PMID:27127343

  10. Ophthalmic Artery Chemosurgery for Less Advanced Intraocular Retinoblastoma: Five Year Review

    PubMed Central

    Abramson, David H.; Marr, Brian P.; Brodie, Scott E.; Dunkel, Ira; Palioura, Sotiria; Gobin, Y. Pierre

    2012-01-01

    Background Ophthalmic artery chemosurgery (OAC) for retinoblastoma was introduced by us 5 years ago for advanced intraocular retinoblastoma. Because the success was higher than with existing alternatives and systemic side effects limited we have now treated less advanced intraocular retinoblastoma (Reese-Ellsworth (RE) I-III and International Classification Retinoblastoma (ICRB) B and C). Methodology/Principal Findings Retrospective review of 5 year experience in eyes with Reese Ellsworth (Table 1) I (7 eyes), II (6 eyes) or III (6 eyes) and/or International Classification (Table 2) B (19 eyes) and C (11 eyes) treated with OAC (melphalan with or without topotecan) introduced directly into the ophthalmic artery. Patient survival was 100%. Ocular event-free survival was 100% for Reese-Ellsworth Groups I, II and III (and 96% for ICRB B and C) at a median of 16 months follow-up. One ICRB Group C (Reese-Ellsworth Vb) eye could not be treated on the second attempt for technical reasons and was therefore enucleated. No patient required a port and only one patient required transfusion of blood products. The electroretinogram (ERG) was unchanged or improved in 14/19 eyes. Conclusions/Significance Ophthalmic artery chemosurgery for retinoblastoma that was Reese-Ellsworth I, II and III (or International Classification B or C) was associated with high success (100% of treatable eyes were retained) and limited toxicity with results that equal or exceed conventional therapy with less toxicity. PMID:22545080

  11. Dosimetry and treatment planning of Occu-Prosta I-125 seeds for intraocular lesions.

    PubMed

    Chaudhari, Suresh; Deshpande, Sudesh; Anand, Vivek; De, Sandeep; Saxena, Sanjay; Dash, A; Basu, Mahua; Samant, Preetam; Kannan, V

    2008-01-01

    Intraocular malignant lesions are frequently encountered in clinical practice. Plaque brachytherapy represents an effective means of treatment for intraocular lesions. Recently Radiopharmaceutical Division, BARC, Mumbai, has indigenously fabricated reasonable-cost I-125 sources. Here we are presenting the preliminary experience of dosimetry of sources, configuration of treatment planning system (TPS) and quality assurance (QA) for eye plaque therapy with Occu-Prosta I-125 seeds, treated in our hospital, for a patient with ocular lesions. I-125 seeds were calibrated using well-type chamber. BrachyVision TPS was configured with Monte Carlo computed radial dose functions and anisotropy functions for I-125 sources. Dose calculated by TPS at different points in central axis and off axis was compared with manually calculated dose. Eye plaque was fabricated of 17 karat pure gold, locally. The seeds were arranged in an outer ring near the edge of the plaque and in concentric rings throughout the plaque. The sources were manually digitized on the TPS, and dose distribution was calculated in three dimensions. Measured activity using cross-calibrated well-type chamber was within +/-10% of the activity specified by the supplier. Difference in TPS-calculated dose and manually calculated dose was within 5%. Treatment time calculated by TPS was in concordance with published data for similar plaque arrangement. PMID:20041047

  12. FBG-based sensorized light pipe for robotic intraocular illumination facilitates bimanual retinal microsurgery.

    PubMed

    Horise, Yuki; He, Xingchi; Gehlbach, Peter; Taylor, Russell; Iordachita, Iulian

    2015-01-01

    In retinal surgery, microsurgical instruments such as micro forceps, scissors and picks are inserted through the eye wall via sclerotomies. A handheld intraocular light source is typically used to visualize the tools during the procedure. Retinal surgery requires precise and stable tool maneuvers as the surgical targets are micro scale, fragile and critical to function. Retinal surgeons typically control an active surgical tool with one hand and an illumination source with the other. In this paper, we present a "smart" light pipe that enables true bimanual surgery via utilization of an active, robot-assisted source of targeted illumination. The novel sensorized smart light pipe measures the contact force between the sclerotomy and its own shaft, thereby accommodating the motion of the patient's eye. Forces at the point of contact with the sclera are detected by fiber Bragg grating (FBG) sensors on the light pipe. Our calibration and validation results demonstrate reliable measurement of the contact force as well as location of the sclerotomy. Preliminary experiments have been conducted to functionally evaluate robotic intraocular illumination. PMID:26736189

  13. Transscleral fixation of closed loop haptic acrylic posterior chamber intraocular lens in aphakic nonvitrectomized eyes

    PubMed Central

    Agrawal, Siddharth; Singh, Vinita; Gupta, Sanjiv Kumar; Misra, Nibha; Srivastava, Rajat M

    2015-01-01

    Purpose: To evaluate the outcome of transscleral fixation of closed loop haptic acrylic posterior chamber intraocular lens (PCIOL) in aphakia in nonvitrectomized eyes. Materials and Methods: Patients with postcataract surgery aphakia, trauma with posterior capsule injury, subluxated crystalline lens, and per operative complications where sulcus implantation was not possible were included over a 1-year period. Scleral fixation of acrylic hydrophilic PCIOL was performed according to the described technique, and the patients were evaluated on the day 1, 3, 14, and at 3 and 12 months postoperatively for IOL centration, pseudophakodonesis, change in best-corrected visual acuity (BCVA), and any other complications. Results: Out of twenty-nine eyes of 24 patients, who completed the study, 25 (86.2%) eyes had improved, 2 (6.9%) eyes showed no change, and 2 (6.9%) eyes had worsening of BCVA. Three (10.3%) eyes developed postoperative complications. A significant improvement in mean BCVA (P < 0.0001) was observed after the procedure. Mean duration of follow-up was 26.2 months (range 22–35 months). Conclusion: The use of closed loop haptic acrylic IOL for scleral fixation appears to be safe and effective alternative to conventional scleral fixated polymethyl methacrylate intraocular lenses. PMID:26576522

  14. Irradiation system for two-photon induced activation of agents in novel intraocular lenses

    NASA Astrophysics Data System (ADS)

    Klämpfl, Florian; Roth, Stephan; Schmidt, Michael

    This paper presents a newly designed irradiation system for the photochemically triggered two-photon activation of an agent loaded in novel intraocular lenses. After activation, this agent suppresses the formation of after-cataract, a very common disease after the treatment of an eye cataract by implanting an intraocular lens. For this application, intrinsic safety is also important: the laser radiation is applied to one of the most light-sensitive organs: the eye. This has to be taken into account during development of the system. Moreover, the activation uses a two-photon process so a relatively small laser focus is required. To address these issues in combination with economic requirements, a mirror based objective was designed and built, specifically tailored to these needs. Besides the laser beam guidance elements, the irradiation system consists of a camera based monitoring module and an illumination unit. While the first part of the paper shows the design of the system, the second part presents the results of the characterization of the system. The paper closes with a conclusion and an outlook discussing what further development is needed to prepare the system for treatments of human eyes.

  15. Intraocular pressure determination in clinically normal red-footed tortoise (Geochelone carbonaria).

    PubMed

    Selmi, André L; Mendes, Guilherme M; McManus, Concepta; Arrais, Patrícia

    2002-03-01

    Intraocular pressure (IOP) reflects a balance between aqueous humor production and outflow and is often an essential ophthalmic diagnostic procedure in animals. The objective of this study was to estimate IOP in clinically normal red-footed tortoises (Geochelone carbonaria) of various sizes by using applanation tonometry. Intraocular pressures were estimated for 25 captive red-footed tortoises (10 males, 10 females, and 5 animals of unknown sex) by using an applanation tonometer after topical anesthesia. Body length ranged from 5.1 to 54.9 cm, measured from nuchal to anal scutes. Five measurements from each eye were obtained by a single observer in an ambient temperature of approximately 30 degrees C. Observer's reliability was good (intraclass r = 0.75), and IOP did not change over the ordered sequence of five replicate measurements. For individual tortoises the correlation for IOP between the left and right eyes was low (r = 0.20). The paired t-test did not show any statistical effect (P = 0.426) for the difference in IOP between the left and right eyes. Mean IOP determined for 10 confirmed males and 10 confirmed females did not differ between sexes (P = 0.244). The mean IOP of five small tortoises (< 10 cm long) was not significantly different (P = 0.244) from that of 20 large tortoises (> 10 cm long). In red-footed tortoises there does not appear to be any relation between carapace length and IOP. PMID:12216794

  16. Hydrophilic Acrylic Intraocular Lens Opacification after Descemet Stripping Automated Endothelial Keratoplasty

    PubMed Central

    Norouzpour, Amir; Zarei-Ghanavati, Siamak

    2016-01-01

    Purpose: To report hydrophilic acylic intraocular lens (IOL) opacification after Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) in an eye with multiple prior intraocular surgeries and iatrogenic aniridia. Case Report: A 34-year-old woman with history of penetrating keratoplasty (PKP) for advanced keratoconus and subsequent Urrets-Zavalia Syndrome (UZS) underwent phacoemulsification and hydrophilic acrylic IOL implantation for her cataract. In order to control post-PKP glaucoma, multiple glaucoma surgeries including two glaucoma drainage implants were performed. As the original corneal graft failed, the patient subsequently underwent re-PKP. Four years later, she underwent DSAEK for treatment of the second graft failure. Ten months after DSAEK, a double semi-circular pattern of IOL opacification was observed on the anterior surface of the IOL. The patient did not report any complaints and we decided not to exchange the IOL. Conclusion: In an eye with UZS and iatrogenic aniridia, IOL opacification may result from direct contact between the IOL surface and exogenous air. Aniridia can be a risk factor for development of IOL opacification after DSAEK. Further studies are required to confirm this hypothesis. PMID:27413506

  17. Iris-claw intraocular lens implantation: Anterior chamber versus retropupillary implantation

    PubMed Central

    Helvacı, Sezer; Demirdüzen, Selahaddin; Öksüz, Hüseyin

    2016-01-01

    Purpose: To compare the outcomes of anterior chamber and retropupillary implantation of iris-claw Artisan intraocular lenses (IOL). Design: Prospective, randomized, single-blinded study. Patients and Methods: Forty eyes of forty aphakic patients were enrolled. Patients were randomized into two groups. Each group includes twenty patients. Group 1 received anterior chamber Artisan IOL implantation. Group 2 received retropupillary Artisan IOL implantation. Preoperative and postoperative corrected distance visual acuity (CDVA), intraocular pressure (IOP), and all complications were noted and compared at 6 months follow-up. Results: Each two groups obtained a significant improvement in CDVA (P < 0.05). Four patients in Group 1 and five patients in Group 2 had significant but nonpermanent increase at IOP values. There were one and two pupillary irregularity in Group 1 and Group 2, respectively. In one patient, a shallow and inferior located retinal detachment were encountered in anterior chamber group. Conclusions: The results were not significantly different between the two fixation techniques for iris-claw lens. The surgery procedure is dependent to surgeon experience and eye's conditions. PMID:26953023

  18. Transconjunctival sutureless intrascleral intraocular lens fixation using intrascleral tunnels guided with catheter and 30-gauge needles.

    PubMed

    Takayama, Kohei; Akimoto, Masayuki; Taguchi, Hogara; Nakagawa, Satoko; Hiroi, Kano

    2015-11-01

    We invented a new method for fixing an intraocular lens (IOL) in the scleral tunnel without using a wide conjunctival incision. Modified bent catheter needles were used to penetrate the IOL haptics through the sclerotomy sites. The IOL haptics were inserted into 30-guage (G) scleral tunnels guided by double 30-G needles piercing the sclera. All procedures were performed through the conjunctiva without wide incision. The procedure does not require special forceps, trocars or fibrin glue, only catheter and 30-G needles. The aid of an assistant was not required to support the IOL haptic. The procedures were easily learnt based on our previous method. As with other transconjunctival sutureless surgeries, patients feel less discomfort and the conjunctiva can be conserved for future glaucoma surgery. Complications included two cases of vitreous haemorrhage (16.7%), and one case each of postoperative hypotony, and iris capture (8.3%). Astigmatism induced by intraocular aberration was the same as we reported previously. Our method for fixing the IOL into the scleral tunnel is innovative, less expensive, less invasive and quick. This modified method is a good alternative for fixing IOL haptics into the sclera. PMID:25855502

  19. Dosimetry and treatment planning of Occu-Prosta I-125 seeds for intraocular lesions

    PubMed Central

    Chaudhari, Suresh; Deshpande, Sudesh; Anand, Vivek; De, Sandeep; Saxena, Sanjay; Dash, A.; Basu, Mahua; Samant, Preetam; Kannan, V.

    2008-01-01

    Intraocular malignant lesions are frequently encountered in clinical practice. Plaque brachytherapy represents an effective means of treatment for intraocular lesions. Recently Radiopharmaceutical Division, BARC, Mumbai, has indigenously fabricated reasonable-cost I-125 sources. Here we are presenting the preliminary experience of dosimetry of sources, configuration of treatment planning system (TPS) and quality assurance (QA) for eye plaque therapy with Occu-Prosta I-125 seeds, treated in our hospital, for a patient with ocular lesions. I-125 seeds were calibrated using well-type chamber. BrachyVision TPS was configured with Monte Carlo computed radial dose functions and anisotropy functions for I-125 sources. Dose calculated by TPS at different points in central axis and off axis was compared with manually calculated dose. Eye plaque was fabricated of 17 karat pure gold, locally. The seeds were arranged in an outer ring near the edge of the plaque and in concentric rings throughout the plaque. The sources were manually digitized on the TPS, and dose distribution was calculated in three dimensions. Measured activity using cross-calibrated well-type chamber was within ±10% of the activity specified by the supplier. Difference in TPS-calculated dose and manually calculated dose was within 5%. Treatment time calculated by TPS was in concordance with published data for similar plaque arrangement. PMID:20041047

  20. Design and evaluation of an intraocular B-scan OCT-guided 36-gauge needle

    NASA Astrophysics Data System (ADS)

    Shen, Jin H.; Joos, Karen M.

    2015-03-01

    Optical coherence tomography imaging is widely used in ophthalmology and optometry clinics for diagnosing retinal disorders. External microscope-mounted OCT operating room systems have imaged retinal changes immediately following surgical manipulations. However, the goal is to image critical surgical maneuvers in real time. External microscope-mounted OCT systems have some limitations with problems tracking constantly moving intraocular surgical instruments, and formation of absolute shadows by the metallic surgical instruments upon the underlying tissues of interest. An intraocular OCT-imaging probe was developed to resolve these problems. A disposable 25-gauge probe tip extended beyond the handpiece, with a 36-gauge needle welded to a disposable tip with its end extending an additional 3.5 mm. A sealed 0.35 mm diameter GRIN lens protected the fiber scanner and focused the scanning beam at a 3 to 4 mm distance. The OCT engine was a very high-resolution spectral-domain optical coherence tomography (SDOCT) system (870 nm, Bioptigen, Inc. Durham, NC) which produced 2000 A-scan lines per B-scan image at a frequency of 5 Hz with the fiber optic oscillations matched to this frequency. Real-time imaging of the needle tip as it touched infrared paper was performed. The B-scan OCT-needle was capable of real-time performance and imaging of the phantom material. In the future, the B-scan OCT-guided needle will be used to perform sub-retinal injections.

  1. Laser flare photometry: a noninvasive, objective, and quantitative method to measure intraocular inflammation.

    PubMed

    Tugal-Tutkun, Ilknur; Herbort, Carl P

    2010-10-01

    Aqueous flare and cells are the two inflammatory parameters of anterior chamber inflammation resulting from disruption of the blood-ocular barriers. When examined with the slit lamp, measurement of intraocular inflammation remains subjective with considerable intra- and interobserver variations. Laser flare cell photometry is an objective quantitative method that enables accurate measurement of these parameters with very high reproducibility. Laser flare photometry allows detection of subclinical alterations in the blood-ocular barriers, identifying subtle pathological changes that could not have been recorded otherwise. With the use of this method, it has been possible to compare the effect of different surgical techniques, surgical adjuncts, and anti-inflammatory medications on intraocular inflammation. Clinical studies of uveitis patients have shown that flare measurements by laser flare photometry allowed precise monitoring of well-defined uveitic entities and prediction of disease relapse. Relationships of laser flare photometry values with complications of uveitis and visual loss further indicate that flare measurement by laser flare photometry should be included in the routine follow-up of patients with uveitis. PMID:19430730

  2. Opacification of hydrophilic intraocular lenses after Descemet stripping automated endothelial keratoplasty

    PubMed Central

    Morgan-Warren, Peter J; Andreatta, Walter; Patel, Amit K

    2015-01-01

    Purpose Opacification of hydrophilic acrylic intraocular lenses (IOLs) is an emerging complication following Descemet stripping automated endothelial keratoplasty (DSAEK). We report six cases and review the current literature. Methods In this retrospective, noncomparative, observational case series, patients with IOL opacification after previous DSAEK surgery were identified from corneal clinic records. Case notes were reviewed for demographic details, indication for DSAEK, IOL model, incidence of rebubbling, and postoperative course. Results Six patients developed IOL opacification after DSAEK. All patients had Fuchs’ endothelial dystrophy and had previously received hydrophilic acrylic IOL models. Central anterior IOL opacification was noted in all six cases. Five cases (83%) had required rebubbling due to dislocated graft tissue, and one had an early postoperative intraocular pressure (IOP) rise. Five cases (83%) were managed conservatively, and one case with a failed graft underwent redo DSAEK and IOL exchange. Conclusion Repeated exposure to intracameral air, raised IOP, and other patient influences may be major etiological factors for IOL opacification after DSAEK. We advise avoiding hydrophilic acrylic IOL models in patients who may require future endothelial keratoplasty. PMID:25709389

  3. Spectral analysis and comparison of mineral deposits forming in opacified intraocular lens and senile cataractous lens

    NASA Astrophysics Data System (ADS)

    Lin, Shan-Yang; Chen, Ko-Hwa; Lin, Chih-Cheng; Cheng, Wen-Ting; Li, Mei-Jane

    2010-10-01

    This preliminary report was attempted to compare the chemical components of mineral deposits on the surfaces of an opacified intraocular lens (IOL) and a calcified senile cataractous lens (SCL) by vibrational spectral diagnosis. An opacified intraocular lens (IOL) was obtained from a 65-year-old male patient who had a significant decrease in visual acuity 2-years after an ocular IOL implantation. Another SCL with grayish white calcified plaque on the subcapsular cortex was isolated from a 79-year-old male patient with complicated cataract after cataract surgery. Optical light microscope was used to observe both samples and gross pictures were taken. Fourier transform infrared (FT-IR) and Raman microspectroscopic techniques were employed to analyze the calcified deposits. The curve-fitting algorithm using the Gaussian function was also used to quantitatively estimate the chemical components in each deposit. The preliminary results of spectral diagnosis indicate that the opacified IOL mainly consisted of the poorly crystalline, immature non-stoichiometric hydroxyapatite (HA) with higher content of type B carbonated apatites. However, the calcified plaque deposited on the SCL was comprised of a mature crystalline stoichiometric HA having higher contents of type A and type B carbonate apatites. More case studies should be examined in future.

  4. Study on intra-ocular lens aberration measurement in-air

    NASA Astrophysics Data System (ADS)

    Wang, Yuanyuan; Chen, Jiaojie; Fen, Haihua; Hu, Chuan; Li, Yiyi

    2010-10-01

    In clinical ophthalmology, the wavefront aberration of human eyes is expressed by Zernike polynomial after cataract surgery and intraocular lens implantation, the human eyes aberration will change. The problem of objective evaluation of wavefront aberration introduced by the Intra-ocular (IOL) in-vivo remains unsolved. This paper introduced the measurement principal of IOL wavefront aberration with expression by Zernike polynominal in air. A Hartmann-Shack wavefront sensor system was constructed to measure the wavefront of IOL and to get the corresponding grid patterns. After a series of computer image processing steps, 7th order with 35 items Zernike coefficients was obtained. The IOL of 20.0D power was measured 5 times by this system to get the spherical aberration about 6.73+/-0.02μm, demonstrating the good repeatability of the system. Ten IOLs with the same 20.0D power but difference in surface curvature were chosen for measurement. The spherical aberration observed were in the range of 2.74μm-11.26μm. These results are valuable for the optical design of IOLs and the aberration analysis of human eyes post-operation.

  5. Factors associated with strabismus after cataract extraction and primary intraocular lens implantation in congenital cataracts

    PubMed Central

    Lee, Soo Jung; Kim, Wan-Soo

    2014-01-01

    AIM To evaluate factors associated with the development of strabismus after cataract extraction and primary intraocular lens implantation. METHODS The medical records of 122 patients, aged 1.5mo to 9y, who had undergone cataract extraction with primary intraocular lens implantation between January 1993 and August 2011 were reviewed. Fourteen patients (17 eyes) with strabismus before cataract surgery were excluded. Patients were divided into those with congenital bilateral cataracts (64 patients, 128 eyes) and those with unilateral cataracts (44 patients, 44 eyes). The associations between the development of strabismus and age at cataract surgery, pre- and post-cataract extraction corrected distance visual acuity (CDVA), interocular CDVA difference, nystagmus, surgical method, and secondary cataract were evaluated. RESULTS Factors significantly associated with the development of strabismus included age at cataract surgery (≤1y), preoperative mean CDVA ≤20/100, presence of nystagmus in the bilateral cataract group and postoperative interocular CDVA difference >20/70 in the unilateral group. Postoperative CDVA ≤20/100 and preservation of posterior capsule, and presence of secondary cataract were significant factors in both groups. CONCLUSION Children with congenital cataracts should be monitored carefully after cataract surgery for the development of strabismus, especially when they underwent surgery at age ≤1y, and they have nystagmus, large postoperative interocular CDVA difference, poor preoperative and postoperative CDVA, preservation of the posterior capsule, or secondary cataract. PMID:24967203

  6. Poly(ortho ester) nanoparticle-based targeted intraocular therapy for controlled release of hydrophilic molecules.

    PubMed

    Palamoor, Mallika; Jablonski, Monica M

    2013-02-01

    Development of an efficient intraocular drug delivery nanosystem remains the most difficult challenge to attain a prolonged therapeutic effect at the site of drug action. The purpose of this work was to develop a biodegradable, long-term sustained release, and biocompatible nanoparticulate system to treat various intraocular diseases. To attain the objectives, poly(ortho ester) (POE), a hydrophobic, surface erodible, and nontoxic polymer, was selected for fabrication of nanoparticles for the first time using a double emulsion solvent evaporation method. The influence of POE molecular weight on particle size, polydispersity index, zeta potential, drug content, in vitro release, degradation, in vitro cytotoxicity, and cell uptake studies was investigated. Drug-loaded nanoparticles had a spherical shape with an average particle diameter from 241 to 298 nm and zeta potential values from -8 to -11 mV. Encapsulation efficiency ranged between 21 and 63%, depending on the type of the water-soluble molecule used. Approximately 20-30% of the loaded drug was released over a period of 14 weeks. The drug release and degradation profiles of nanoparticles followed perfect zero-order kinetics confirming the POE-surface erosion mechanism. In vitro cytotoxicity and cell uptake studies revealed the cyto-compatible nature and nonendocytic behavior of POE nanoparticles. Collectively, POE nanoparticles are a very promising vehicle for sustained delivery of therapeutics to the back of the eye. PMID:23256649

  7. Effect of oral administration of carprofen on intraocular pressure in normal dogs.

    PubMed

    Meekins, J M; Overton, T L; Rankin, A J; Roush, J K

    2016-08-01

    The aim of this study was to determine the effect of oral administration of carprofen on intraocular pressure in normal dogs. Twelve young adult beagle dogs were randomly assigned to treatment (n = 6) or control (n = 6) groups. After an 11-day acclimation period, the treatment group received approximately 2.2 mg/kg carprofen per os every 12 h for 7 days, and the control group received a placebo gel capsule containing no drug per os every 12 h for 7 days. Intraocular pressure (IOP) was measured by a rebound tonometer at three time points per day (8 am, 2 pm, and 8 pm) during the acclimation (days 1-11) and treatment (days 12-18) phases and for 48 h (days 19-20) after the completion of treatment. There was no statistically significant change in IOP for either eye in the dogs receiving oral carprofen during the treatment phase (days 12-18). After day 4, no significant daily IOP changes were seen in control group dogs. Carprofen administered orally every 12 h for 7 days had no effect on IOP in normal beagle dogs. An acclimation period to frequent IOP measurements of at least 5 days is necessary to establish baseline IOP values and minimize possible anxiety-related effects on IOP measurements. PMID:26923773

  8. Bone and joint infections by Mucorales, Scedosporium, Fusarium and even rarer fungi.

    PubMed

    Koehler, Philipp; Tacke, Daniela; Cornely, Oliver A

    2016-01-01

    Mucorales, Scedosporium and Fusarium species are rarely considered as cause for bone and joint infections. However, these moulds are emerging as important fungal pathogens in immunocompromised and immunocompetent patients. Typical pre-disposing host conditions are immunosuppression and diabetes. Most common causative pathogens are Mucorales followed by Scedosporium and Fusarium. Acremonium and Phialemonium species are rare but some case reports exist. MRI is the gold standard imaging technique. Tissue specimens obtained as aspirates, imaging guided biopsy or open surgery need mycological and histopathological work-up for genus and species identification. Multimodal treatment strategies combine surgical debridement, drainage of joints or abscesses, removal of infected prosthetic joints and systemic antifungals. The treatment of mucormycosis is polyene based and may be combined with either posaconazole or - in rare cases - caspofungin. As Scedosporium species are intrinsically resistant to polyenes and azoles show absence of in vitro activity, voriconazole plus synergistic treatment regimens become the therapeutic standard. In fusariosis, fungal susceptibility is virtually impossible to predict, so that combination treatment of voriconazole and lipid-based amphotericin B should be the first-line strategy while susceptibility results are pending. In the absence of randomized controlled trials, infections due to the above moulds should be registered, e.g. in the registries of the European Confederation of Medical Mycology (ECMM). PMID:24809926

  9. Ocular and neural distribution of feline herpesvirus-1 during active and latent experimental infection in cats

    PubMed Central

    2013-01-01

    Background Herpes simplex virus 1 (HSV-1) and varicella zoster virus (VZV) cause extensive intra-ocular and neural infections in humans and are closely related to Felid herpes virus 1 (FeHV-1). We report the extent of intra-ocular replication and the extent and morphological aspects of neural replication during the acute and latent phases of FeHV-1 infection. Juvenile, SPF cats were inoculated with FeHV-1. Additional cats were used as negative controls. Cats were euthanized on days 6, 10, and 30 post-inoculation. Results FeHV-1 was isolated from the conjunctiva, cornea, uveal tract, retina, optic nerve, ciliary ganglion (CG), pterygopalatine ganglion (PTPG), trigeminal ganglion (TG), brainstem, visual cortex, cerebellum, and olfactory bulb of infected cats during the acute phase, but not the cranial cervical ganglion (CCG) and optic chiasm. Viral DNA was detected in all tissues during acute infection by a real-time quantitative PCR assay. On day 30, viral DNA was detected in all TG, all CCG, and 2 PTPG. Histologically mild inflammation and ganglion cell loss were noted within the TG during acute, but not latent infection. Using linear regression, a strong correlation existed between clinical score and day 30 viral DNA copy number within the TG. Conclusions The correlation between clinical score and day 30 viral DNA copy number suggests the severity of the acute clinical infection is related to the quantity of latent viral DNA. The histologic response was similar to that seen during HSV-1 or VZV infection. To the author’s knowledge this is the first report of FeHV-1 infection involving intraocular structures and autonomic ganglia. PMID:24053192

  10. Characterization of the Cephalosporium acremonium pcbAB gene encoding alpha-aminoadipyl-cysteinyl-valine synthetase, a large multidomain peptide synthetase: linkage to the pcbC gene as a cluster of early cephalosporin biosynthetic genes and evidence of multiple functional domains.

    PubMed Central

    Gutiérrez, S; Díez, B; Montenegro, E; Martín, J F

    1991-01-01

    A 24-kb region of Cephalosporium acremonium C10 DNA was cloned by hybridization with the pcbAB and pcbC genes of Penicillium chrysogenum. A 3.2-kb BamHI fragment of this region complemented the mutation in the structural pcbC gene of the C. acremonium N2 mutant, resulting in cephalosporin production. A functional alpha-aminoadipyl-cysteinyl-valine (ACV) synthetase was encoded by a 15.6-kb EcoRI-BamHI DNA fragment, as shown by complementation of an ACV synthetase-deficient mutant of P. chrysogenum. Two transcripts of 1.15 and 11.4 kb were found by Northern (RNA blot) hybridization with probes internal to the pcbC and pcbAB genes, respectively. An open reading frame of 11,136 bp was located upstream of the pcbC gene that matched the 11.4-kb transcript initiation and termination regions. It encoded a protein of 3,712 amino acids with a deduced Mr of 414,791. The nucleotide sequence of the gene showed 62.9% similarity to the pcbAB gene encoding the ACV synthetase of P. chrysogenum; 54.9% of the amino acids were identical in both ACV synthetases. Three highly repetitive regions occur in the deduced amino acid sequence of C. acremonium ACV synthetase. Each is similar to the three repetitive domains in the deduced sequence of P. chrysogenum ACV synthetase and also to the amino acid sequence of gramicidin synthetase I and tyrocidine synthetase I of Bacillus brevis. These regions probably correspond to amino acid activating domains in the ACV synthetase protein. In addition, a thioesterase domain was present in the ACV synthetases of both fungi. A similarity has been found between the domains existing in multienzyme nonribosomal peptide synthetases and polyketide and fatty acid synthetases. The pcbAB gene is linked to the pcbC gene, forming a cluster of early cephalosporin-biosynthetic genes. Images PMID:1706706

  11. Reduction of intraocular pressure and improvement of vision after cataract surgeries in angle closure glaucoma with concomitant cataract patients

    PubMed Central

    Zhang, Zong-Mei; Niu, Qing; Nie, Yan; Zhang, Jin

    2015-01-01

    Objective: This study is to compare the efficacy of three different cataract surgeries in eyes with angle closure glaucoma (ACG) with concomitant cataract. Methods: A retrospective comparative analysis of 106 ACG patients (112 eyes) with concomitant cataract was conducted between February, 2012 and February, 2014. Clinical outcomes of ACG patients with concomitant cataract underwent phacoemulsification and intraocular lens implantation (group A, n = 34, 36 eyes, angle closure < 180°); combined phacoemulsification, intraocular lens implantation, and goniosynechialysis (group B, n = 43, 45 eyes, angle closure, 180°~270°); and combined phacoemulsification, intraocular lens implantation, and trabeculectomy (group C, n = 29, 31 eyes, angle closure > 270°) were compared during a 6-month follow-up. Results: There were no statistical differences among the 3 groups in pre-operative or post-operative average visual acuity (VA), intraocular pressure (IOP), anterior chamber depth (ACD), and angle opening distance (AOD) (all P > 0.05). Post-operative VA, IOP, ACD, AOD and the degree of angle opening in the 3 groups were all improved as compared with pre-operative levels (all P < 0.05). No statistical difference was detected among the 3 groups in the incidence of complications (χ2 = 0.376, P = 0.829). Conclusion: Phacoemulsification alone, combined phacoemulsification/goniosynechialysis, and combined phacoemulsification/trabeculectomy provide safe, effective, predictable, and stable options of cataract surgery for treatment of ACG with concomitant cataract. PMID:26629184

  12. Uveitis-glaucoma-hyphema syndrome caused by posterior chamber intraocular lens--a rare complication in pediatric cataract surgery.

    PubMed

    Lin, Chun-Ju; Tan, Chau-Yi; Lin, Szu-Yuan; Jou, Jieh-Ren

    2008-01-01

    We report a case of postoperative uveitis-glaucome-hyphema (UGH) syndrome following pediatric cataract surgery due to posterior chamber intraocular lens (PC-IOL). Slit-lamp examination revealed the optic of PC-IOL migrated into anterior chamber. The PC-IOL explantation was performed and ocular inflammation subsided. PMID:19230361

  13. Choroidal Neovascularization Is Inhibited in Splenic-Denervated or Splenectomized Mice with a Concomitant Decrease in Intraocular Macrophage

    PubMed Central

    Tan, Xue; Fujiu, Katsuhito; Manabe, Ichiro; Nishida, Junko; Yamagishi, Reiko; Terashima, Yuya; Matsushima, Kouji; Kaburaki, Toshikatsu; Nagai, Ryozo; Yanagi, Yasuo

    2016-01-01

    Purpose To determine the involvement of sympathetic activity in choroidal neovascularization (CNV) using laser-induced CNV in a mouse model. Methods We investigated changes in the proportions of intraocular lymphocytes, granulocytes, and three macrophage subtypes (Ly6Chi, Ly6Cint, and Ly6Clo) after laser injury in mice using flow cytometry, and evaluated CNV lesion size in mice lacking inflammatory cells. Further, we evaluated the lesion size in mice administered the β3 receptor antagonist, splenic-denervated and splenectomized mice. We also assessed changes in the proportions of intraocular macrophages and peripheral blood monocytes in splenic-denervated and splenectomized mice. Lastly, lesion size was compared between splenic-denervated mice with or without adoptive transfer of macrophages following laser injury. After Ly5.1 mice spleen-derived Ly6Chi cells were transferred into Ly5.2 mice, the proportions of intraocular Ly5.1+Ly6Chi cells were compared. Results In WT mice, the proportion of CD4+ T cells recruited into the eye increased progressively from day 3 to day 7 after laser injury, whereas, intraocular CD8+ T cells did not change significantly. Proportions of B220+ cells, granulocytes, and two subtypes of intraocular macrophages (Ly6Chi and Ly6Clo) peaked at day 3 following laser injury. In contrast, Ly6Cint/loCD64+ subtype showed a significantly higher percentage at day 7 after laser injury. There were no differences in lesion size between CD4–/–or Rag2–/–mice and controls, whereas lesion size was significantly reduced in CCR2−/− mice and clodronate liposome-treated mice. CNV lesion area was significantly reduced in mice with β3 blocker treatment, splenic-denervated and splenectomized mice compared with controls. Intraocular Ly6Chi macrophages were also reduced by splenic denervation or splenectomy. Adoptive transfer of spleen-derived Ly6Chi cells increased the lesion size in splenic-denervated mice. Compared with controls, intraocular

  14. Prediction error and accuracy of intraocular lens power calculation in pediatric patient comparing SRK II and Pediatric IOL Calculator

    PubMed Central

    2010-01-01

    Background Despite growing number of intraocular lens power calculation formulas, there is no evidence that these formulas have good predictive accuracy in pediatric, whose eyes are still undergoing rapid growth and refractive changes. This study is intended to compare the prediction error and the accuracy of predictability of intraocular lens power calculation in pediatric patients at 3 month post cataract surgery with primary implantation of an intraocular lens using SRK II versus Pediatric IOL Calculator for pediatric intraocular lens calculation. Pediatric IOL Calculator is a modification of SRK II using Holladay algorithm. This program attempts to predict the refraction of a pseudophakic child as he grows, using a Holladay algorithm model. This model is based on refraction measurements of pediatric aphakic eyes. Pediatric IOL Calculator uses computer software for intraocular lens calculation. Methods This comparative study consists of 31 eyes (24 patients) that successfully underwent cataract surgery and intraocular lens implantations. All patients were 12 years old and below (range: 4 months to 12 years old). Patients were randomized into 2 groups; SRK II group and Pediatric IOL Calculator group using envelope technique sampling procedure. Intraocular lens power calculations were made using either SRK II or Pediatric IOL Calculator for pediatric intraocular lens calculation based on the printed technique selected for every patient. Thirteen patients were assigned for SRK II group and another 11 patients for Pediatric IOL Calculator group. For SRK II group, the predicted postoperative refraction is based on the patient's axial length and is aimed for emmetropic at the time of surgery. However for Pediatric IOL Calculator group, the predicted postoperative refraction is aimed for emmetropic spherical equivalent at age 2 years old. The postoperative refractive outcome was taken as the spherical equivalent of the refraction at 3 month postoperative follow-up. The

  15. Splenectomy promotes indirect elimination of intraocular tumors by CD8+ T cells that is associated with IFNγ- and Fas/FasL-dependent activation of intratumoral macrophages.

    PubMed

    Miller, Maxine R; Mandell, Jonathan B; Beatty, Kelly M; Harvey, Stephen A K; Rizzo, Michael J; Previte, Dana M; Thorne, Stephen H; McKenna, Kyle C

    2014-12-01

    Ocular immune privilege (IP) limits the immune surveillance of intraocular tumors as certain immunogenic tumor cell lines (P815, E.G7-OVA) that are rejected when transplanted in the skin grow progressively when placed in the anterior chamber of the eye. As splenectomy (SPLNX) is known to terminate ocular IP, we characterized the immune mechanisms responsible for rejection of intraocular tumors in SPLNX mice as a first step toward identifying how to restore tumoricidal activity within the eye. CD8(+) T cells, IFNγ, and FasL, but not perforin, or TNFα were required for the elimination of intraocular E.G7-OVA tumors that culminated in destruction of the eye (ocular phthisis). IFNγ and FasL did not target tumor cells directly as the majority of SPLNX IFNγR1(-/-) mice and Fas-defective lpr mice failed to eliminate intraocular E.G7-OVA tumors that expressed Fas and IFNγR1. Bone marrow chimeras revealed that IFNγR1 and Fas expression on immune cells was most critical for rejection, and SPLNX increased the frequency of activated macrophages (Mϕ) within intraocular tumors in an IFNγ- and Fas/FasL-dependent manner, suggesting an immune cell target of IFNγ and Fas. As depletion of Mϕs limited CD8 T cell-mediated rejection of intraocular tumors in SPLNX mice, our data support a model in which IFNγ- and Fas/FasL-dependent activation of intratumoral Mϕs by CD8(+) T cells promotes severe intraocular inflammation that indirectly eliminates intraocular tumors by inducing phthisis, and suggests that immunosuppressive mechanisms that maintain ocular IP interfere with the interaction between CD8(+) T cells and Mϕs to limit the immunosurveillance of intraocular tumors. PMID:25248763

  16. Effects of Different Levels of Intraocular Stray Light on Kinetic Perimetry Findings

    PubMed Central

    2015-01-01

    Purpose To evaluate the effect of different levels of intraocular stray light on kinetic perimetry findings. Methods Twenty-five eyes of 25 healthy young participants were examined by automated kinetic perimetry (Octopus 900) using Goldmann stimuli III4e, I4e, I3e, I2e, and I1e. Each stimulus was presented with a velocity of 3°/s at 24 meridians with 15° intervals. Four levels of intraocular stray light were induced using non-white opacity filter (WOF) filters and WOFs applied to the clear plastic eye covers of the participants. The visual acuity, pupil diameter, isopter area, and kinetic sensitivity of each meridian were analyzed for each WOF density. Results Visual acuity deteriorated with increasing WOF densities (p < 0.01). With a visual acuity of 0.1 LogMAR units, the isopter areas for III4e, I4e, I3e, I2e, and I1e decreased by -32.7 degree2 (-0.2%), -255.7 degree2 (-2.6%), -381.2 degree2 (-6.2%), -314.8 degree2 (-12.8%), and -59.2 degree2 (-15.2%), respectively; kinetic sensitivity for those stimuli decreased by -0.1 degree (-0.1%), -0.8 degree (-1.4%), -1.6 degree (-3.7%), -2.7 degree (-9.7%), and -1.7 degree (-16.2%), respectively. The pupil diameter with each WOF density was not significantly different. Conclusion Kinetic perimetry measurements with a high-intensity stimulus (i.e., III4e) were unaffected by intraocular stray light. In contrast, measurements with the I4e, I3e, I2e, and I1e stimuli, especially I2e and I1e, were affected. Changes in the shape of the isopter resulting from opacity must be monitored, especially in cases of smaller and lower-intensity stimuli. PMID:25965816

  17. Intraocular and extraocular cameras for retinal prostheses: Effects of foveation by means of visual prosthesis simulation

    NASA Astrophysics Data System (ADS)

    McIntosh, Benjamin Patrick

    Blindness due to Age-Related Macular Degeneration and Retinitis Pigmentosa is unfortunately both widespread and largely incurable. Advances in visual prostheses that can restore functional vision in those afflicted by these diseases have evolved rapidly from new areas of research in ophthalmology and biomedical engineering. This thesis is focused on further advancing the state-of-the-art of both visual prostheses and implantable biomedical devices. A novel real-time system with a high performance head-mounted display is described that enables enhanced realistic simulation of intraocular retinal prostheses. A set of visual psychophysics experiments is presented using the visual prosthesis simulator that quantify, in several ways, the benefit of foveation afforded by an eye-pointed camera (such as an eye-tracked extraocular camera or an implantable intraocular camera) as compared with a head-pointed camera. A visual search experiment demonstrates a significant improvement in the time to locate a target on a screen when using an eye-pointed camera. A reach and grasp experiment demonstrates a 20% to 70% improvement in time to grasp an object when using an eye-pointed camera, with the improvement maximized when the percept is blurred. A navigation and mobility experiment shows a 10% faster walking speed and a 50% better ability to avoid obstacles when using an eye-pointed camera. Improvements to implantable biomedical devices are also described, including the design and testing of VLSI-integrable positive mobile ion contamination sensors and humidity sensors that can validate the hermeticity of biomedical device packages encapsulated by hermetic coatings, and can provide early warning of leaks or contamination that may jeopardize the implant. The positive mobile ion contamination sensors are shown to be sensitive to externally applied contamination. A model is proposed to describe sensitivity as a function of device geometry, and verified experimentally. Guidelines are

  18. A Circadian and Cardiac Intraocular Pressure Sensor for Smart Implantable Lens.

    PubMed

    Donida, Achille; Di Dato, Giuseppe; Cunzolo, Paolo; Sala, Marco; Piffaretti, Filippo; Orsatti, Paolo; Barrettino, Diego

    2015-12-01

    This paper presents a new system to measure the Intraocular Pressure (IOP) with very high accuracy (0.036 mbar) used for monitoring glaucoma. The system not only monitors the daily variation of the IOP (circadian IOP), but also allows to perform an spectral analysis of the pressure signal generated by the heartbeat (cardiac IOP). The system comprises a piezoresistive pressure sensor, an application-specific integrated circuit (ASIC) to read out the sensor data and an external reader installed on customized glasses. The ASIC readout electronics combines chopping modulation with correlated double sampling (CDS) in order to eliminate both the amplifier offset and the chopper ripple at the sampling frequency. In addition, programmable current sources are used to compensate for the atmospheric pressure ( 800-1200 mbar ) and the circadian component (± 7 mbar) thus allowing to read out the very weak cardiac signals (± 1.6 mbar) with a maximum accuracy of 0.036 mbar. PMID:26800549

  19. Abnormal increase of intraocular pressure in fellow eye after severe ocular trauma

    PubMed Central

    Vaajanen, Anu; Tuulonen, Anja

    2016-01-01

    Abstract Background: An ocular injury can lead to secondary glaucoma in the traumatized eye in 3% to 20% of cases. Literature on the risk of developing elevated intraocular pressure in the nontraumatized fellow eye is scant. Clinicians treating ocular traumas should also bear in mind sympathetic ophthalmia, a rare bilateral granulomatous panuveitis following accidental or surgical trauma to 1 eye. Case report: We report a case of high-pressure glaucoma of the fellow eye without any signs of uveitis. The left eye of a 24-year-old man was injured in an inadvertent movement during a free-time table-tennis match. The eye was severely crushed, leading to blindness. His right eye developed medically uncontrolled high-pressure glaucoma only 1 month after the injury. Conclusion: To the best of our knowledge, there are no previous reports of post-traumatic glaucoma in the nontraumatized eye after open-globe injury. PMID:27495058

  20. [The calculation of the intraocular lens power based on raytracing methods: a systematic review].

    PubMed

    Steiner, Deborah; Hoffmann, Peter; Goldblum, David

    2013-04-01

    A problem in cataract surgery consists in the preoperative identification of the appropriate intraocular lens (IOL) power. Different calculation approaches have been developed for this purpose; raytracing methods represent one of the most exact but also mathematically more challenging methods. This article gives a systematic overview of the different raytracing calculations available and described in the literature and compares their results. It has been shown that raytracing includes physical measurements and IOL manufacturing data but no approximations. The prediction error is close to zero and an essential advantage is the applicability to different conditions without the need of modifications. Compared to the classical formulae the raytracing methods are more precise overall, but due to the various data and property situations they are hardly comparable yet. The raytracing calculations represent a good alternative to the 3rd generation formulae. They minimize refractive errors, are wider applicable and provide better results overall, particularly in eyes with preconditions. PMID:23629771

  1. Treatment of ophidism-induced bilateral canine cataract by extracapsular lens extraction and intraocular lens implantation.

    PubMed

    Kibar, M; Evereklioğlu, C; Doğan, Z

    2014-01-01

    The aim of this study was to report a new cause of cataract, namely snake bite induced cataract in a dog. A 3-year-old male mongrel dog was referred to our clinic for the assessment of cataract in both eyes. The dog was bitten by a snake nearly 4 months ago. A 40 dioptre acrylic lens with 13 mm haptics was implanted into the lens capsule. In the left eye, posterior synechia was detected in the temporal part of the iris, but decentration of the intraocular lens was not observed. To the best of our knowledge, this is the first report of bilateral cataract caused by ophidism and treated by surgical intervention in a dog. PMID:27175143

  2. Combined transscleral fixation of an artificial iris prosthesis with an intraocular lens.

    PubMed

    Gunenc, Uzeyır; Ozturk, Taylan; Arikan, Gul; Kaya, Mahmut

    2016-02-01

    Post-traumatic aniridia combined with aphakia may be seen after globe injury. Aside from esthetic aspects, partial or total loss of the iris tissue may also be related to various degrees of glare and photophobia. Such patients suffer from severe visual impairment secondary to aphakia. Herein we describe a novel surgical technique for the management of an aphakic eye with traumatic aniridia for a patient who underwent transscleral fixation of a custom-tailored artificial iris prosthesis combined with a rigid intraocular lens (IOL). Tight suturing of the IOL haptic eyelets on the silicone iris prosthesis and fixation of such a complex to the scleral wall may provide excellent cosmetic and functional outcomes in aphakic eyes with aniridia. PMID:26840171

  3. Oxygen saturation changes in the optic nerve head during acute intraocular pressure elevation in monkeys

    NASA Astrophysics Data System (ADS)

    Khoobehi, Bahram; Kawano, Hiroyuki; Ning, Jinfeng; Burgoyne, Claude F.; Rice, David A.; Khan, Fareeha; Thompson, Hilary W.; Beach, James M.

    2009-02-01

    Background and Objective: To evaluate the effect of an acute elevated intraocular pressure (IOP) on oxygen saturation of structures of the optic nerve head. Study Design/Materials and Methods: In the cynomolgus monkey eye, IOP was set to 10 mm Hg, and then raised to 30, 45, and 55 mm Hg. The ONH and overlying vessels were imaged using a fundus camera attached to a hyperspectral imaging system (HSI) at 10 and 30 minutes after IOP elevation. Results: Raising IOP from 10 to 30 mm Hg did not significantly (P < 0.0001) change saturation in vessels or ONH tissue structures but at 55 mm Hg, all structures showed significant reduction. Conclusions: Quantitative assay of the blood oxygen saturation in structures on the surface and overlying the optic nerve head is possible using hyperspectral imaging techniques.

  4. Mouse model of brachytherapy in consort with enucleation for treatment of malignant intraocular melanoma

    SciTech Connect

    Niederkorn, J.; Sanborn, G.E.; Scarbrough, E.E. )

    1990-06-01

    The efficacy of brachytherapy in the treatment and prevention of metastasis of intraocular melanoma was investigated in a mouse model. A highly metastatic subline of B16 melanoma was transplanted into the anterior segment of C57BL/6 mice and allowed to grow. Brachytherapy was delivered by means of miniature iodine 125 seeds implanted in shallow subcutaneous pockets of the upper eyelid margin of these mice, and 25 Gy of radiation was delivered between days 12 and 14. This brachytherapy reduced both the tumor volume and the number of mitotic figures per high-power field compared with irradiated controls. In a second experiment, 25 Gy of brachytherapy was delivered before enucleation, straddling enucleation, and after enucleation; there was a significant reduction in metastasis when radiation was delivered prior to enucleation. This model may be useful in conducting further studies involving brachytherapy with 125I plaque implants.

  5. The effect of long-term use of intranasal steroids on intraocular pressure

    PubMed Central

    Şimşek, Ali; Bayraktar, Cem; Doğan, Sedat; Karataş, Mehmet; Sarıkaya, Yasin

    2016-01-01

    Long-term use of topical nasal steroids (especially older generation steroids) has been shown to elevate intraocular pressure (IOP), but newer intranasal steroids are thought to have a minimal effect on IOP because of their low bioavailability. This study aimed to investigate alterations in IOP with two commonly used intranasal steroids for a 6-month period of time. One-hundred allergic rhinitis patients, divided equally into two groups, used mometasone furoate and fluticasone furoate intranasal steroids for 6 months. IOPs were measured before treatment and repeated at the 3rd, 6th, 12th, and 24th weeks of treatment. The IOPs of the groups were then compared. No statistically significant alteration was observed between the groups during the treatment time period. It was found that new generation intranasal steroids can be used safely, and there may not be an increased risk of IOP elevation in prolonged use in normal healthy people. PMID:27354761

  6. The Road Ahead to Continuous 24-Hour Intraocular Pressure Monitoring in Glaucoma

    PubMed Central

    Mansouri, Kaweh

    2014-01-01

    Intraocular pressure (IOP) is the only treatable risk factor for glaucoma. Yet, current glaucoma management usually relies on single IOP measurements during clinic hours despite the fact that IOP is a dynamic parameter with individual rhythms. Single IOP measurements underpin all major clinical guidelines on treatment of glaucoma. Other potentially informative parameters, such as IOP fluctuations and peak IOP, have been neglected, and effects of IOP-lowering interventions on such measures are largely unknown. The search for continuous 24-hour IOP monitoring started over 50 years ago, but only recent technological advances have provided clinician-researchers with devices for continuous IOP monitoring. Herein, we discuss innovative approaches with permanent and temporary devices for 24-hour IOP monitoring, such as a contact lens sensor. Despite being in their infancy, these devices may soon enable clinicians to use 24-hour IOP data to improve glaucoma management and reduce the glaucoma-related burden of disease. PMID:25279129

  7. Bilateral spontaneous anterior dislocation of intraocular lens with the capsular bag in a patient with pseudoexfoliation

    PubMed Central

    Bhattacharjee, Harsha; Saxena, Rushil Kumar; Medhi, Jnanankar

    2015-01-01

    We report a rare case of bilateral spontaneous anterior partial in-the-bag intraocular lens (IOL) dislocation in a 75-year-old man with pseudoexfoliation (PXF). He underwent uneventful phacoemulsification in both eyes with in-the-bag IOL implantation 9 years back. In the right eye, single piece poly (methyl methacrylate) (PMMA) IOL (+19 D) and in the left eye, single piece acrylic foldable IOL (+19 D) were implanted. An attempt at pharmacological IOL repositioning was unsuccessful. The dislocated IOLs were explanted and exchanged with scleral suture fixated PMMA IOLs. Vision improved to 20/30 in both eyes following surgery, without any associated ocular morbidity. We believe that zonular weakness secondary to PXF, capsular contraction, and myopia together were the predisposing factors for partial anterior dislocation of IOLs and IOL exchange with scleral suture fixation of IOL is a safe and effective treatment option. PMID:26655008

  8. Surface modification of polymethyl methacrylate intraocular lenses by plasma for improvement of antithrombogenicity and transmittance

    NASA Astrophysics Data System (ADS)

    Zhang, Lihua; Wu, Di; Chen, Yashao; Wang, Xiaoli; Zhao, Guowei; Wan, Haiyan; Huang, Changzheng

    2009-05-01

    To improve antithrombogenicity and reduce ultraviolet transmittance, polymethyl methacrylate intraocular lenses (PMMA IOLs) were pretreated with Ar plasma and combined with heparin (Hp), with polyglycol (PEG) and with both Hp and PEG in a plasma atmosphere. The resulting modified PMMA IOLs denoted as PEG-PMMA, Hp-PMMA and Hp-PEG-PMMA were characterized by attenuated total reflectance Fourier transfer infrared spectroscopy (ATR-FTIR), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), ultraviolet-visible spectroscopy (UV-vis), contact angle (CA) and platelet adhesion experiments. The results indicated that Hp and PEG had been successfully immobilized onto the surfaces of PMMA IOLs. Antithrombogenicity was improved remarkably and ultraviolet transmittance was reduced as well.

  9. Intraocular lens design for treating high myopia based on individual eye model

    NASA Astrophysics Data System (ADS)

    Wang, Yang; Wang, Zhaoqi; Wang, Yan; Zuo, Tong

    2007-02-01

    In this research, we firstly design the phakic intraocular lens (PIOL) based on individual eye model with optical design software ZEMAX. The individual PIOL is designed to correct the defocus and astigmatism, and then we compare the PIOL power calculated from the individual eye model with that from the experiential formula. Close values of PIOL power are obtained between the individual eye model and the formula, but the suggested method has more accuracy with more functions. The impact of PIOL decentration on human eye is evaluated, including rotation decentration, flat axis decentration, steep axis decentration and axial movement of PIOL, which is impossible with traditional method. To control the PIOL decentration errors, we give the limit values of PIOL decentration for the specific eye in this study.

  10. Rotation stability of a toric intraocular lens with a second capsular tension ring.

    PubMed

    Sagiv, Oded; Sachs, Dan

    2015-05-01

    An Acrysof toric intraocular lens (IOL) and a capsular tension ring (CTR) were implanted in the highly myopic eye of a 74-year-old white man during cataract surgery. On the first postoperative day, the IOL was found 90 degrees from the required position, with a consequent high amount of astigmatism. A second procedure was performed and because it was not possible to secure the toric IOL in the correct position, an additional in-the-bag CTR was inserted, with an immediate optimal outcome. The IOL remained stable up to the final follow-up examination. Co-implantation of a toric IOL and a single CTR has been reported. In our case, 2 CTRs were required to fixate the toric IOL in the correct position. This procedure is simple and safe and should be considered in cases of postoperatively misaligned toric IOLs. PMID:25937341

  11. Quality of vision in patients implanted with aspherical and spherical intraocular lens: Intraindividual comparison

    PubMed Central

    Semeraro, Francesco; Romano, Mario R; Duse, Sarah; Costagliola, Ciro

    2014-01-01

    Aims: To compare the quality of vision in pseudophakic patients implanted with aspherical and spherical intraocular lenses (IOLs). Materials and Methods: Randomized prospective longitudinal intrapatient comparison between aspherical and spherical IOLs performed on 22 patients who underwent bilateral cataract surgery. Best corrected visual acuity, subjective contrast sensitivity, Strehl ratio and spherical aberrations (SA), and higher order wavefront aberrations for a 3.5 mm and a 6.0 mm pupil were measured after 3 months of cataract surgery. Results: SA (Z4,0) decreased significantly in eyes with aspherical IOL implant (P =0.004). Modulation transfer function (MTF) and point spread function (PSF) resulted no significant difference between the two groups (P =0.87; P = 0.32). Conclusion: Although the SA is significantly lower in eyes implanted with aspherical IOL, the quality of vision determined with MTF and PSF does not significantly differ for subjective and objective parameters that were analyzed. PMID:24008781

  12. Necrotizing scleritis after intraocular surgery associated with the use of polyester nonabsorbable sutures.

    PubMed

    Stokes, John; Wright, Mark; Ramaesh, Kanna; Smith, Colin; Dhillon, Baljean

    2003-09-01

    We present 2 elderly patients who developed necrotizing scleritis after cataract extraction in which the wound was sutured with polyester. In the first case, a 73-year-old woman who had right phacoemulsification via a limbal incision developed necrotizing scleritis 8 months after surgery. The eye became progressively painful and phthisical, necessitating enucleation. Microscopic examination of the enucleated globe showed a predominantly lymphocytic infiltration of the ocular tissues with no evidence of an infectious agent. In the second case, a 78-year-old woman had bilateral extracapsular cataract extraction through a limbal incision closed with a polyester suture. The patient presented 3 years later with bilateral necrotizing sclerokeratitis. No underlying systemic vasculitis or autoimmune condition was identified in either patient. To our knowledge, the association of necrotizing scleritis after intraocular surgery and polyester fiber suture material (Mersilene) has not been described. PMID:14522309

  13. Optimization of an intraocular lens for correction of advanced corneal refractive errors.

    PubMed

    Wadbro, Eddie; Hallberg, Per; Schedin, Staffan

    2016-06-01

    Based on numerical 3D ray tracing, we propose a new procedure to optimize personalized intra-ocular lenses (IOLs). The 3D ray tracing was based on measured corneal elevation data from patients who suffered from advanced keratoconus. A mathematical shape description of the posterior IOL surface, by means of a tensor product cubic Hermite spline, was implemented. The optimized lenses provide significantly reduced aberrations. Our results include a trade-off study that suggests that it is possible to considerably reduce the aberrations with only minor perturbations of an ideal spherical lens. The proposed procedure can be applied for correction of aberrations of any optical system by modifying a single surface. PMID:27411190

  14. Surface PEGylation of intraocular lens for PCO prevention: An in vivo evaluation.

    PubMed

    Xu, Xu; Tang, Jun-Mei; Han, Yue-Mei; Wang, Wei; Chen, Hao; Lin, Quan-Kui

    2016-07-01

    Posterior capsular opacification (PCO) is a common complication in cataract surgery. The development of PCO is attributed to the combination of adhesion, migration, proliferation, and transdifferentiation of the residual lens epithelial cells (LEC) onto the interface of intraocular lens (IOL) material and lens posterior, in which the initial adhesion is the beginning step and plays important roles. In the present study, hydrophilic polyethylene glycol (PEG) was immobilized onto IOL surface via plasma-aided chemical grafting procedure. The attenuated total reflection - Fourier transform infrared (ATR-FTIR) and contact angle (CA) - measurements indicate the successful surface PEGylation, as well as the excellent hydrophilicity of the surfaces. Compared with pristine IOL, the PEGylation does not influent its optical property, whereas the initial adhesion of LEC is greatly inhibited. In vivo ocular implantation results show that the PEGylated IOL presents good in vivo biocompatibility, and can effectively prevent the PCO development. PMID:26980548

  15. Intraocular Ossification in the GSP/pe Chicken With Imperfect Albinism.

    PubMed

    Shibuya, K; Kinoshita, K; Mizutani, M; Oshima, A; Yamashita, R; Matsuda, Y

    2015-07-01

    The eyes of 2 male and 2 female GSP/pe chickens, the imperfect albino strain, were investigated at 52 weeks of age. Aged chickens of the GSP/pe colony became blind with bilateral ocular enlargement and opaque lenses. Affected eyes (bilateral in 2 males and unilateral in 2 females) were hard and difficult to section; histologic specimens were processed after decalcification. A large portion of the posterior chamber was occupied by cancellous bone containing fibrous and cartilaginous foci. Osseous tissues developed adjacent to the choroid, and no retinal pigment epithelium (RPE) was detected between osseous tissues and the choroid. Small segments of degenerate neuronal retina were scattered in the osseous tissue. The irises and ciliary bodies were deformed by osseous tissue, and the lenses had severe cataracts. These observations suggest that the intraocular osseous tissue may be derived from RPE in the hereditary incomplete-albino strain of chickens. PMID:25421422

  16. Evaluation of intraocular lens implant location in the eyeball basing on the Purkinje images

    NASA Astrophysics Data System (ADS)

    Jóźwik, A.; Siedlecki, D.; Zajac, M.

    2012-01-01

    Intraocular lens (IOL) is an artificial implant substituting natural crystalline lens which is non-transparent due to cataract. Incorrect location of the IOL in the eyeball (e.g. its shift or tilt) causes significant deterioration of patient's vision. The analysis of Purkinje images (i.e. reflections from successive refracting surfaces in the eye) enables to determine the real IOL location and thus helps in evaluating the retinal image quality. The experimental setup for Purkinje images recording consists of illuminator, composed of a number of infrared LEDs, telecentric lens and detector (CCD camera). Analysis of mutual position of particular reflections enables to evaluate the lens location in respect to the corneal axis. The actual measurements are realized on artificial eye model, what allows to estimate the precision of the algorithm applied in the calculations. In the future the experimental set-up will be adapted to measure the eyes of real patients.

  17. Surgical technique for transscleral fixation of a foldable posterior chamber intraocular lens.

    PubMed

    Yepez, Juan B; de Yepez, Jazmin Cedeño; Valero, Alejandro; Arevalo, J Fernando

    2006-01-01

    The safety and efficacy of a modified technique for transscleral fixation of a foldable posterior chamber intraocular lens (IOL) for intracapsular aphakia (secondary IOL) or after complicated phacoemulsification was evaluated. All eyes had inadequate or no posterior capsular support. Follow-up was between 4 and 26 months (mean, 12 months). Uncorrected visual acuity improved (> 2 lines) in all patients. During follow-up, the IOL was correctly positioned in all cases. There were no major complications, such as endophthalmitis or suture erosion through the conjunctiva at the site of fixation. No patient required further surgical interventions. This modified technique of transscleral fixation of foldable posterior chamber IOL offers the advantages of a small incision and rapid visual rehabilitation, and minimizes the risk of intraoperative and postoperative complications. PMID:16749265

  18. Location and composition of haptics of posterior chamber intraocular lenses. Histopathologic study of postmortem eyes.

    PubMed

    McDonnell, P J; Champion, R; Green, W R

    1987-02-01

    Of 110 eyes with posterior chamber intraocular lenses (IOLs) examined postmortem, 37% had both haptics outside of the capsular bag; 57% had one haptic in the capsular bag and the other haptic outside of the bag. Typically, these optics were decentered by 1 to 2 mm. Only six eyes (5%) had both haptics within the capsular bag. Erosion into the ciliary sulcus produced obliteration of the major arterial circle of the iris in 12 eyes (11%). The local tissue response to eroding haptics was similar for haptics composed of polypropylene and haptics composed of polymethylmethacrylate (PMMA). The authors found considerable discrepancy between the actual location of haptics and the surgeon's desired location (i.e., capsular bag or ciliary sulcus). Most of these cases were clinically successful. PMID:3574878

  19. Corneal injection track: an unusual complication of intraocular lens implantation and review

    PubMed Central

    Lok, Julie Y.C.; Young, Alvin L.

    2015-01-01

    Phacoemulsification is the main gold standard for cataract operation in the developed world together with foldable intraocular lens (IOL) implantation by injection, allowing for stable wound construction and less postoperative astigmatism. It is a safe procedure with high success rate with the advancement in machines, improvement of IOL injection systems and further maturation of surgeons' techniques. Despite the large number of operations performed every day, foldable IOL injection leading to an intra-stromal corneal track is a very rare complication. We report a case of this unusual finding in a 70-year-old gentleman who has undergone cataract operation in November 2011 in our hospital and will review on the complications related to foldable IOL injection. PMID:26086020

  20. Spontaneous disinsertion of a multipiece foldable acrylic intraocular lens haptic 3 and 12 months after implantation.

    PubMed

    Por, Yong Ming; Chee, Soon-Phaik

    2004-05-01

    We report 2 cases of spontaneous postoperative haptic disinsertion with the Alcon AcrySof MA60BM posterior chamber intraocular lens (PC IOL). A 14-year-old girl with a history of acute retinal necrosis and pars plana vitrectomy with lensectomy for retinal detachment repair had secondary implantation of a PC IOL in the ciliary sulcus. Three months later, the superior haptic disinserted from the optic and dislocated into the anterior chamber. In the second case, a 22-year-old man had lens aspiration and PC IOL implantation in the capsular bag. One year after surgery, the PC IOL had a similar problem, with the disinserted superior haptic remaining in the capsular bag while the optic and inferior haptic dislocated into the anterior chamber. In both patients, the PC IOLs were exchanged for rigid single-piece PC IOLs. The patients have had no further problems. PMID:15130659

  1. Radiation Pretreatment Does Not Protect the Rat Optic Nerve From Elevated Intraocular Pressure–Induced Injury

    PubMed Central

    Johnson, Elaine C.; Cepurna, William O.; Choi, Dongseok; Choe, Tiffany E.; Morrison, John C.

    2015-01-01

    Purpose. Optic nerve injury has been found to be dramatically reduced in a genetic mouse glaucoma model following exposure to sublethal, head-only irradiation. In this study, the same radiation treatment was used prior to experimental induction of elevated intraocular pressure (IOP) to determine if radiation is neuroprotective in another glaucoma model. Methods. Episcleral vein injection of hypertonic saline was used to elevate IOP unilaterally in two groups of rats: (1) otherwise untreated and (2) radiation pretreated, n > 25/group. Intraocular pressure histories were collected for 5 weeks, when optic nerves were prepared and graded for injury. Statistical analyses were used to compare IOP history and nerve injury. The density of microglia and macrophages in two nerve head regions was determined by Iba1 immunolabeling. Results. Mean and peak IOP elevations were not different between the two glaucoma model groups. Mean optic nerve injury grades were not different in glaucoma model optic nerves and were equivalent to approximately 35% of axons degenerating. Nerves selected for lower mean or peak IOP elevations did not differ in optic nerve injury. Similarly, nerves selected for lower injury grade did not differ in IOP exposure. By multiple regression modeling, nerve injury grade was most significantly associated with mean IOP (P < 0.002). There was no significant effect of radiation treatment. Iba1+ cell density was not altered by radiation treatment. Conclusions. In contrast to previous observations in a mouse genetic glaucoma model, head-only irradiation offers the adult rat optic nerve no protection from optic nerve degeneration due to chronic, experimentally induced IOP elevation. PMID:25525172

  2. Vision in semi-aquatic snakes: Intraocular morphology, accommodation, and eye: Body allometry

    NASA Astrophysics Data System (ADS)

    Plylar, Helen Bond

    Vision in vertebrates generally relies on the refractive power of the cornea and crystalline lens to facilitate vision. Light from the environment enters the eye and is refracted by the cornea and lens onto the retina for production of an image. When an animal with a system designed for air submerges underwater, the refractive power of the cornea is lost. Semi-aquatic animals (e.g., water snakes, turtles, aquatic mammals) must overcome this loss of corneal refractive power through visual accommodation. Accommodation relies on change of the position or shape of the lens to change the focal length of the optical system. Intraocular muscles and fibers facilitate lenticular displacement and deformation. Snakes, in general, are largely unstudied in terms of visual acuity and intraocular morphology. I used light microscopy and scanning electron microscopy to examine differences in eye anatomy between five sympatric colubrid snake species (Nerodia cyclopion, N. fasciata, N. rhombifer, Pantherophis obsoletus, and Thamnophis proximus) from Southeast Louisiana. I discovered previously undescribed structures associated with the lens in semi-aquatic species. Photorefractive methods were used to assess refractive error. While all species overcame the expected hyperopia imposed by submergence, there was interspecific variation in refractive error. To assess scaling of eye size with body size, I measure of eye size, head size, and body size in Nerodia cyclopion and N. fasciata from the SLU Vertebrate Museum. In both species, body size increases at a significantly faster rate than head size and eye size (negative allometry). Small snakes have large eyes relative to body size, and large snakes have relatively small eyes. There were interspecific differences in scaling of eye size with body size, where N. fasciata had larger eye diameter, but N. cyclopion had longer eyes (axial length).

  3. Brinzolamide nanocrystal formulations for ophthalmic delivery: reduction of elevated intraocular pressure in vivo.

    PubMed

    Tuomela, Annika; Liu, Peng; Puranen, Jooseppi; Rönkkö, Seppo; Laaksonen, Timo; Kalesnykas, Giedrius; Oksala, Olli; Ilkka, Jukka; Laru, Johanna; Järvinen, Kristiina; Hirvonen, Jouni; Peltonen, Leena

    2014-06-01

    Nanocrystal-based drug delivery systems provide important tools for ocular formulation development, especially when considering poorly soluble drugs. The objective of the study was to formulate ophthalmic, intraocular pressure (IOP) reducing, nanocrystal suspensions from a poorly soluble drug, brinzolamide (BRA), using a rapid wet milling technique, and to investigate their IOP reducing effect in vivo. Different stabilizers for the nanocrystals were screened (hydroxypropyl methylcellulose (HPMC), poloxamer F127 and F68, polysorbate 80) and HPMC was found to be the only successful stabilizer. In order to investigate both the effect of an added absorption enhancer (polysorbate 80) and the impact of the free drug in the nanocrystal suspension, formulations in phosphate buffered saline (PBS) at pH 7.4 and pH 4.5 were prepared. Particle size, polydispersity (PI), solid state (DSC), morphology (SEM) as well as dissolution behavior and the uniformity of the formulations were characterized. There was rapid dissolution of BRA (in PBS pH 7.4) from all the nanocrystal formulations; after 1 min 100% of the drug was fully dissolved. The effect was significantly pronounced at pH 4.5, where the dissolved fraction of drug was the highest. The cytotoxicity of nanocrystal formulations to human corneal epithelial cell (HCE-T) viability was tested. The effects of the nanocrystal formulations and the commercial product on the cell viability were comparable. The intraocular pressure (IOP) lowering effect was investigated in vivo using a modern rat ocular hypertensive model and elevated IOP reduction was seen in vivo with all the formulations. Notably, the reduction achieved in experimentally elevated IOP was comparable to that obtained with a marketed product. In conclusion, various BRA nanocrystal formulations, which all showed advantageous dissolution and absorption behavior, were successfully formulated. PMID:24680962

  4. The Effect of Swimming Goggles on Intraocular Pressure and Blood Flow within the Optic Nerve Head

    PubMed Central

    Ma, Kyoung Tak; Chung, Woo Suk; Seo, Kyoung Yul; Seong, Gong Je

    2007-01-01

    Purpose Goggles are frequently worn in the sport of swimming and are designed to form a seal around the periorbital tissue orbit. The resultant pressure on the eye may have the potential to affect intraocular pressure and blood flow of the optic nerve head. This study evaluates the influence of wearing swimming goggles on intraocular pressure (IOP) and blood flow of the ocular nerve head (ONH) in normal subjects. Materials and Methods Thirty healthy participants took part in this study. The IOP of each participant was measured using a Goldmann tonometer. Measurements were taken immediately before putting on swimming goggles, at 5, 10, 30, and 60 minutes after putting on swimming goggles, and then immediately after taking off the goggles. Blood flow of the ONH was measured using the Heidelberg retinal flowmeter. Results The average IOP before, during and after wearing the swimming goggles were 11.88 ± 2.82 mmHg, 14.20 ± 2.81mmHg and 11.78 ± 2.89 mmHg, respectively. The IOP increased immediately after putting on the goggles (p < 0.05) and then returned to normal values immediately after removal (p > 0.05). Blood flow of the ONH was 336.60 ± 89.07 Arbitrary Units (AU) before and 319.18 ± 96.02 AU after the goggles were worn (p < 0.05). Conclusion A small but significant IOP elevation was observed immediately after the swimming goggles were put on. This elevated IOP was maintained while the goggles were kept on, and then returned to normal levels as soon as they were taken off. Blood flow of the ONH did not change significantly throughout the experiment. These facts should be considered for safety concerns, especially in advanced glaucoma patients. PMID:17963338

  5. Short-term intraocular pressure changes after intravitreal injection of bevacizumab in diabetic retinopathy patients

    PubMed Central

    Farhood, Qasim Kadhim; Twfeeq, Sinan Mohammad

    2014-01-01

    Background This study examined the changes in short-term intraocular pressure (IOP) in a prospective series of patients undergoing intravitreal bevacizumab injection. The aim was to evaluate the frequency and predictive factors related to intraocular pressure (IOP) elevation in patients receiving intravitreal bevacizumab. Patients and methods This study included 52 patients with diabetic retinopathy between 28 to 75 years of age with a mean age of 51 years; 30 (58%) were females, and 22 (42%) were males. All patients received bevacizumab (1.25 mg/0.05 mL) injected intravitreally in a standard fashion between May 2012 to February 2013 in the AL-Jumhoury teaching hospital. IOP was measured at baseline, 5, 10, and 30 minutes after injection using Goldman applanation tonometry. Statistics Data were analyzed using the SPSS v.12.0 for windows. Basic, demographic, and clinical data were analyzed using means, proportions, and appropriate 95% confidence intervals (CIs). Results Most patients (85%) were diagnosed with proliferative diabetic retinopathy, while 15% presented with diabetic macular edema. The mean IOP values at baseline, 5, 10, and 30 minutes after injection were 14.0 mmHg (95% CI 13.4–14.7), 36.1 mmHg (95% CI 33.5–38.6), 25.7 mmHg (95% CI 23.8–27.5), and 15.5 mmHg (95% CI 12.4–16.51), respectively. Regression analysis showed a trend toward phakic patients having higher IOP at 30 minutes. Conclusion Intravitreal injection of bevacizumab is safe with respect to short-term IOP changes, as almost all IOP returned to a safe range (<25 mmHg) within 30 minutes. Elevated IOP 30 minutes after injection only occurs rarely, so routine prophylactic use of anti-glaucoma medication is not indicated. PMID:24707164

  6. Wavefront analysis and modulation transfer function of three multifocal intraocular lenses

    PubMed Central

    Santhiago, Marcony R; Netto, Marcelo V; Barreto, Jackson; Gomes, Beatriz AF; Schaefer, Arthur; Kara-Junior, Newton

    2010-01-01

    Purpose: To evaluate wavefront performance and modulation transfer function (MTF) in the human eye after the implantation of diffractive or refractive multifocal intraocular lenses (IOLs). Materials and Methods: This was a prospective, interventional, comparative, nonrandomized clinical study. Uncorrected distance and near visual acuity, and wavefront analysis including MTF curves (iTrace aberrometer, Tracey Technologies, Houston, TX, USA) were measured in 60 patients after bilateral IOL implantation with 6 months of follow-up. Forty eyes received the diffractive ReSTOR (Alcon), 40 eyes received the refractive ReZoom (Advanced Medical Optics) and 40 eyes, the Tecnis ZM900 (Advanced Medical Optics). The comparison of MTF and aberration between the intraocular lenses was performed using analysis of variance (ANOVA), followed by the Dunn test when necessary. Results: The mean uncorrected distance visual acuity was similar in all three groups of multifocal IOLs. The ReSTOR group provided better uncorrected near visual acuity than the ReZoom group (P < 0.001), but similar to the Tecnis group. Spherical aberration was significantly higher in the ReZoom group (P = 0.007). Similar MTF curves were found for the aspheric multifocal IOL Tecnis and the spheric multifocal IOL ReSTOR, and both performed better than the multifocal IOL ReZoom in a 5 mm pupil (P < 0.001 at all spatial frequencies). Conclusions: Diffractive IOLs studied presented similar MTF curves for a 5 mm pupil diameter. Both diffractive IOLs showed similar spherical aberration, which was significantly better with the full-diffractive IOL Tecnis than with the refractive IOL ReZoom. PMID:20195032

  7. In Vivo Imaging of Intraocular Fluidics in Vitrectomized Swine Eyes Using a Digital Fluoroscopy System

    PubMed Central

    Tandogan, Tamer; Khoramnia, Ramin; Auffarth, Gerd Uwe; Koss, Michael Janusz; Choi, Chul Young

    2016-01-01

    Purpose. To describe the characteristics of intraocular fluidics during cataract surgery in swine eyes with prior vitrectomy. Methods. We prepared three groups of enucleated swine eyes (nonvitrectomized, core, and totally vitrectomized). Irrigation and aspiration were performed (2.7 mm conventional sleeved phacosystem) using a balanced saline solution mixed with a water-soluble radiopaque contrast medium at 1 : 1 ratio. We imaged the eyes using a digital fluoroscopy system (DFS) during phacoemulsification and compared the characteristics of the intraocular fluid dynamics between the groups. Results. The anterior chamber depth (ACD) after the commencement of irrigation differed between groups (2.25 ± 0.06 mm; 2.33 ± 0.06 mm; 3.17 ± 0.11 mm), as well as the height of the fluid flowing from the anterior chamber into the posterior cavity that was identified by lifting up the iris to correct the infusion deviation syndrome (0.00 ± 0.00 mm; 0.41 ± 0.04 mm; 2.19 ± 0.35 mm). Conclusions. DFS demonstrated differences in fluid dynamics during phacoemulsification in swine eyes with or without prior vitrectomy. In completely vitrectomized eyes, the large ACD, which developed during phacoemulsification, could be reduced by lifting the iris and allowing the fluid to shift to the posterior cavity. Recognizing the differences in fluidics of vitrectomized eyes as compared to those of the nonvitrectomized eyes may reduce the frequency of intraoperative complications. PMID:27127645

  8. High Refractive Index Polysiloxane as Injectable, In Situ Curable Accommodating Intraocular Lens

    PubMed Central

    Hao, Xiaojuan; Jeffery, Justine L.; Le, Tam P.T.; McFarland, Gail; Johnson, Graham; Mulder, Roger J.; Garrett, Qian; Manns, Fabrice; Nankivil, Derek; Arrieta, Esdras; Ho, Arthur; Parel, Jean-Marie; Hughes, Timothy C.

    2012-01-01

    Functionalised siloxane macromonomers, with properties designed for application as an injectable, in situ curable accommodating intraocular lens (A-IOL), were prepared via reequilibration of a phenyl group-containing polysiloxane of very high molecular weight with octamethylcyclotetrasiloxane (D4) and 2,4,6,8-tetra(n-propyl-3-methacrylate)-2,4,6,8-tetramethylcyclotetrasiloxane (D4AM) in toluene using trifluoromethanesulfonic acid as a catalyst. Hexaethyldisiloxane was used as an end group to control the molecular weight of the polymer. The generated polymers had a consistency suitable for injection into the empty lens capsule. The polymers contained a low ratio of polymerisable groups so that, in the presence of a photo-initiator, they could be cured on demand in situ within 5 minutes under irradiation of blue light to form an intraocular lens within the lens capsule. All resulting polysiloxane soft gels had a low elastic modulus and thus should be able to restore accommodation. The pre-cure viscosity and post-cure modulus of the generated polysiloxanes were controlled by the end group and D4AM concentrations respectively in the re-equilibration reactions. The refractive index could be precisely controlled by adjusting the aromatic ratio in the polymer to suit such application as an artificial lens. Lens stretching experiments with both human and non-human primate cadaver lenses of different ages refilled with polysiloxane polymers provided a significant increase in amplitude of accommodation (up to 4 D more than that of the respective natural lens). Both in vitro cytotoxicity study using L929 cell lines and in vivo biocompatibility study in rabbit models demonstrated the non-cytotoxicity and ocular biocompatibility of the polymer. PMID:22594975

  9. One Year Follow-Up After Veriflex Phakic Intraocular Lenses Implantation for Correction of Myopia

    PubMed Central

    Pjano, Melisa Ahmedbegovic; Biscevic, Alma; Grisevic, Senad; Pidro, Ajla; Ratkovic, Mirko; Bohac, Maja; Husovic, Amila Alikadic; Gojak, Refet

    2016-01-01

    Objectives: The aim of this study was to evaluate visual and refractive outcomes after Veriflex phakic intraocular lenses (pIOL) implantation in moderately myopic eyes as well as postoperative complications. Methods: This prospective clinical study included 40 eyes of 26 patients which underwent implantation of Veriflex for correction of myopia from -6.00 to -14.50 diopters (D) in the Eye Clinic Svjetlost Sarajevo, from January 2011 to January 2014. Uncorrected distance visual acuity (UDVA), manifest residual spherical equivalent (MRSE), intraocular pressure (IOP), endothelial cell (EC) density were evaluated at one, three, six and 12 months. Other complications in postoperative period were evaluated. For statistical analysis SPSS for Windows and Microsoft Excel were used. Results: Out of 26 patients 14 had binocular and 12 monocular procedure, with mean age of 29.8±6.5 years. After 12 months mean UDVA was 0.73±0.20. Mean MRSE was -0.39±0.31D and 90% of eyes had MRSE within ±1D. EC loss was 7.18±4.33%. There was no significant change of IOP by the end of 12 months follow up period. The only intraoperative complication was hyphema and occurred in one eye. Few postoperative complications were: subclinical inflammation in three eyes (7,5%), pigment dispersion in four eyes (10%), ovalisation of papilla in 2 eyes (5%) and decentration of pIOL in 2 eyes (5%). Conclusion: Implantation of iris-claw phakic lenses Veriflex for treating moderately high myopia is a procedure with good visual and refractive results and few postoperative complications. PMID:27482131

  10. Ocular health assessment, tear production, and intraocular pressure in the Andros Island iguana (Cyclura cychlura cychlura).

    PubMed

    Wojick, Kimberlee B; Naples, Lisa M; Knapp, Charles R

    2013-03-01

    The purpose of this study was to assess the ocular health of a wild population of Andros Island iguanas (Cyclura cychlura cychlura) and determine reference values for tear production and intraocular pressure (IOP) for this species. Fifty-two iguanas, 20 males and 32 females, ranging in size from 11.1- to 51.0-cm snout-to-vent length (SVL), were included in the sample set, with measurements obtained from each eye. No abnormalities were found on ophthalmic examination, with the exception of mild, focal chemosis in one individual and periocular ticks in 52% of iguanas. Tear production was measured using the phenol red thread test, and IOP was measured using the TonoVet rebound tonometer set on the P (undefined species) setting. No significant difference was found between males and females for either measurement. No significant difference was found between right and left eyes for intraocular pressure; however, a significant difference was found between eyes for tear production values. The mean (+/- SD) of IOP in the left and right eyes were 4.77 +/- 1.88 mm Hg and 5.12 +/- 2.52 mm Hg, respectively, with a range of 1-11 mm Hg. The mean (+/- SD) of tear production in the left and right eyes were 10.63 +/- 6.89 mm/15 sec (range 1-28 mm/15 sec) and 12.44 +/- 7.52 mm/15 sec (range 1-23 mm/15 sec), respectively. A positive correlation was found between SVL and all ocular parameters measured. This study provides an assessment of ocular health, as well as baseline values for IOP and tear production, in the Andros Island iguana. PMID:23505711

  11. Glaucoma Surgery Calculator: Limited Additive Effect of Phacoemulsification on Intraocular Pressure in Ab Interno Trabeculectomy

    PubMed Central

    Schuman, Joel S.; Brown, Eric N.

    2016-01-01

    Purpose To compare intraocular pressure (IOP) reduction and to develop a predictive surgery calculator based on the results between trabectome-mediated ab interno trabeculectomy in pseudophakic patients versus phacoemulsification combined with trabectome-mediated ab interno trabeculectomy in phakic patients. Methods This observational surgical cohort study analyzed pseudophakic patients who received trabectome-mediated ab interno trabeculectomy (AIT) or phacoemulsification combined with AIT (phaco-AIT). Follow up for less than 12 months or neovascular glaucoma led to exclusion. Missing data was imputed by generating 5 similar but non-identical datasets. Groups were matched using Coarsened Exact Matching based on age, gender, type of glaucoma, race, preoperative number of glaucoma medications and baseline intraocular pressure (IOP). Linear regression was used to examine the outcome measures consisting of IOP and medications. Results Of 949 cases, 587 were included consisting of 235 AIT and 352 phaco-AIT. Baseline IOP between groups was statistically significant (p≤0.01) in linear regression models and was minimized after Coarsened Exact Matching. An increment of 1 mmHg in baseline IOP was associated with a 0.73±0.03 mmHg IOP reduction. Phaco-AIT had an IOP reduction that was only 0.73±0.32 mmHg greater than that of AIT. The resulting calculator to determine IOP reduction consisted of the formula -13.54+0.73 × (phacoemulsification yes:1, no:0) + 0.73 × (baseline IOP) + 0.59 × (secondary open angle glaucoma yes:1, no:0) + 0.03 × (age) + 0.09 × (medications). Conclusions This predictive calculator for minimally invasive glaucoma surgery can assist clinical decision making. Only a small additional IOP reduction was observed when phacoemulsification was added to AIT. Patients with a higher baseline IOP had a greater IOP reduction. PMID:27077914

  12. A Longitudinal Study of Association between Adiposity Markers and Intraocular Pressure: The Kangbuk Samsung Health Study

    PubMed Central

    Zhao, Di; Kim, Myung Hun; Pastor-Barriuso, Roberto; Chang, Yoosoo; Ryu, Seungho; Zhang, Yiyi; Rampal, Sanjay; Shin, Hocheol; Kim, Joon Mo; Friedman, David S.; Guallar, Eliseo; Cho, Juhee

    2016-01-01

    Importance Intraocular pressure (IOP) reduction or stabilization is the only proven method for glaucoma management. Identifying risk factors for IOP is crucial to understand the pathophysiology of glaucoma. Objective To examine the associations of change in body mass index (BMI), waist circumference, and percent fat mass with change in intraocular pressure (IOP) in a large sample of Korean adults. Design, setting and participants Cohort study of 274,064 young and middle age Korean adults with normal fundoscopic findings who attended annual or biennial health exams from January 1, 2002 to Feb 28, 2010 (577,981 screening visits). Exposures BMI, waist circumference, and percent fat mass. Main Outcome Measure(s) At each visit, IOP was measured in both eyes with automated noncontact tonometers. Results In multivariable-adjusted models, the average increase in IOP (95% confidence intervals) over time per interquartile increase in BMI (1.26 kg/m2), waist circumference (6.20 cm), and percent fat mass (3.40%) were 0.18 mmHg (0.17 to 0.19), 0.27 mmHg (0.26 to 0.29), and 0.10 mmHg (0.09 to 0.11), respectively (all P < 0.001). The association was stronger in men compared to women (P < 0.001) and it was only slightly attenuated after including diabetes and hypertension as potential mediators in the model. Conclusions and Relevance Increases in adiposity were significantly associated with an increase in IOP in a large cohort of Korean adults attending health screening visits, an association that was stronger for central obesity. Further research is needed to understand better the underlying mechanisms of this association, and to establish the role of weight gain in increasing IOP and the risk of glaucoma and its complications. PMID:26731527

  13. Hookworm infection

    MedlinePlus

    Hookworm disease; Ground itch; Ancylostoma duodenale infection; Necator americanus infection; Parasitic infection - hookworm ... in getting the disease is walking barefoot on ground where there are feces of people who have ...

  14. Yeast Infections

    MedlinePlus

    ... antibiotics, it can multiply and cause an infection. Yeast infections affect different parts of the body in different ways: Thrush is a yeast infection that causes white patches in your mouth Candida ...

  15. Vaginal Infections

    MedlinePlus

    ... Two common vaginal infections are bacterial vaginosis and yeast infections . Bacterial vaginosis (BV) happens when a certain ... increases the chances that you’ll get BV. Yeast infections happen when a fungus (a type of ...

  16. Bone Infections

    MedlinePlus

    ... of the body, bones can get infected. The infections are usually bacterial, but can also be fungal. ... bloodstream. People who are at risk for bone infections include those with diabetes, poor circulation, or recent ...

  17. Eye Infections

    MedlinePlus

    Your eyes can get infections from bacteria, fungi, or viruses. Eye infections can occur in different parts of the eye and can affect just one eye or both. Two common eye infections are Conjunctivitis - also known as pinkeye. Conjunctivitis is ...

  18. Comparison of visual outcomes and subjective visual quality after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of apodized diffractive bifocal intraocular lenses

    PubMed Central

    Gundersen, Kjell Gunnar; Potvin, Rick

    2016-01-01

    Purpose To compare the visual acuity (VA) and quality of vision between bilateral implantation of a trifocal intraocular lens (IOL) and blended bifocal IOLs with an intermediate add in the dominant eye and a near add in the nondominant eye. Patients and methods Patients with either trifocal or blended bifocal IOLs implanted were recruited after surgery. Subjects returned for a single diagnostic visit between 3 and 24 months after surgery. VA was tested at various distances, including low-contrast acuity and acuity at their preferred reading distance. A binocular defocus curve was obtained, and subjective visual function and quality of vision were evaluated. Results Twenty-five trifocal subjects and 30 blended bifocal subjects were enrolled. There were no significant differences in low-contrast acuity, preferred reading distance, or acuity at that reading distance. Binocular vision at 4 m, 60 cm, and 40 cm was not statistically significantly different. The trifocal provided statistically significantly better visual acuity (P<0.05) at vergences from −0.5 to −1.5 D (from 2 m to 67 cm viewing distance, P<0.05). There was no statistically significant difference in the near vision subscale scores of the 39-question National Eye Institute Visual Function Questionnaire or the overall scores of the Quality of Vision questionnaire, though significantly more trifocal subjects reported that the observed visual disturbances were “bothersome” (P<0.05). Conclusion Both lens modalities provided subjects with excellent binocular near and distance vision, with similar low rates of visual disturbances and good reported functional vision. The trifocal IOL provided significantly better intermediate VA in the viewing distance range of 2 m to 67 cm, corresponding to viewing things such as a car dashboard or grocery shelf. VA was similar between groups at viewing distances from 60 to 40 cm, corresponding to computer or reading distance. PMID:27274184

  19. Light transmission through intraocular lenses with or without yellow chromophore (blue light filter) and its potential influence on functional vision in everyday environmental conditions.

    PubMed

    Owczarek, Grzegorz; Gralewicz, Grzegorz; Skuza, Natalia; Jurowski, Piotr

    2016-01-01

    In this research the factors used to evaluate the light transmission through two types of acrylic hydrophobic intraocular lenses, one that contained yellow chromophore that blocks blue light transmission and the other which did not contain that filter, were defined according to various light condition, e.g., daylight and at night. The potential influence of light transmission trough intraocular lenses with or without yellow chromophore on functional vision in everyday environmental conditions was analysed. PMID:26327154

  20. Light transmission through intraocular lenses with or without yellow chromophore (blue light filter) and its potential influence on functional vision in everyday environmental conditions

    PubMed Central

    Owczarek, Grzegorz; Gralewicz, Grzegorz; Skuza, Natalia; Jurowski, Piotr

    2016-01-01

    In this research the factors used to evaluate the light transmission through two types of acrylic hydrophobic intraocular lenses, one that contained yellow chromophore that blocks blue light transmission and the other which did not contain that filter, were defined according to various light condition, e.g., daylight and at night. The potential influence of light transmission trough intraocular lenses with or without yellow chromophore on functional vision in everyday environmental conditions was analysed. PMID:26327154

  1. Malik`s Technique of Single Loop Fixation of Posterior Chamber Intraocular Lens in Presence of Partial Capsular Support

    PubMed Central

    Singh Malik, Krishan Pal; Goel, Ruchi; Kishore, Divya; Nagpal, Smriti

    2015-01-01

    Single loop fixation of posterior chamber intraocular lens in the presence of partial capsular support is usually performed by creation of additional scleral flap or tunnel. This extra port may expose the suture holding the intraocular lens or the tucked-in lens haptics to the outside environment thereby increasing the risk of endophthalmitis. We describe a technique of single loop fixation where the scleral tunnel is created adjacent to the site with the absent capsule, the leading haptic is placed on the capsular scaffold, the trailing haptic is tied to 9-0 polypropylene, and the suture is then secured to the inner edge of the scleral lip with enough tension to center the optics and the wound is then closed. The suture knot gets buried within the scleral tunnel with no external communication and does not require a separate port. It is an easy, safe, fast and reproducible technique with a lens tilt of less than 2°. PMID:26962380

  2. The Effect of ND:YAG Laser Posterior Capsulotomy Size on Refraction, Intraocular Pressure, and Macular Thickness

    PubMed Central

    Karahan, Eyyup; Tuncer, Ibrahim; Zengin, Mehmet Ozgur

    2014-01-01

    Purpose. The aim of this study is to examine the influence of capsulotomy size on, spherical equivalent (SE), intraocular pressure (IOP), and macular thickness. Materials and Methods. Sixty-eight patients were examined preoperatively and 1, 4, and 12 weeks after Nd:YAG capsulotomy. Patients were divided into two groups based on the postoperative capsulotomy size. Changes in SE, IOP, and macular thickness were compared between two groups. Results. We found a higher hyperopic shift in large capsulotomy group. In both groups 1 and 2, IOP increased 1 week postoperatively. Intraocular pressure rise in group 2 was higher than in group 1. Both groups had increased macular thickness at 1 week postoperatively. The degree of macular thickening was similar in group 1 and group 2. Comment. Patients who underwent a larger capsulotomy have a higher hyperopic shift and IOP elevation. Rise in macular thickness was similar in large and small capsulotomy groups. PMID:24724016

  3. A noncontact intraocular pressure measurement device using a micro reflected air pressure sensor for the prediagnosis of glaucoma

    NASA Astrophysics Data System (ADS)

    Kim, Kyoung Hwan; Kim, Byeong Hee; Seo, Young Ho

    2012-03-01

    This study investigates a novel, portable tonometer using a micro reflected air pressure sensor for the prediagnosis of glaucoma. Because glaucoma progresses slowly and is not painful, glaucoma patients require a portable prediagnosis system to periodically measure intraocular pressure at home. Conventionally, intraocular pressure is measured by an air-puff tonometer whereby the cornea is deformed by a short pulse of air pressure and the magnitude of the corneal deformation is measured by optic systems such as a combination of laser- and photodiodes. In this study, a micro reflected air pressure sensor was designed, fabricated, and tested in order to measure the magnitude of corneal deformation without optic systems. In an experimental study, artificial eyes with different internal pressures were fabricated and these pressures were measured by the aforementioned system.

  4. The Effect of ND:YAG Laser Posterior Capsulotomy Size on Refraction, Intraocular Pressure, and Macular Thickness.

    PubMed

    Karahan, Eyyup; Tuncer, Ibrahim; Zengin, Mehmet Ozgur

    2014-01-01

    Purpose. The aim of this study is to examine the influence of capsulotomy size on, spherical equivalent (SE), intraocular pressure (IOP), and macular thickness. Materials and Methods. Sixty-eight patients were examined preoperatively and 1, 4, and 12 weeks after Nd:YAG capsulotomy. Patients were divided into two groups based on the postoperative capsulotomy size. Changes in SE, IOP, and macular thickness were compared between two groups. Results. We found a higher hyperopic shift in large capsulotomy group. In both groups 1 and 2, IOP increased 1 week postoperatively. Intraocular pressure rise in group 2 was higher than in group 1. Both groups had increased macular thickness at 1 week postoperatively. The degree of macular thickening was similar in group 1 and group 2. Comment. Patients who underwent a larger capsulotomy have a higher hyperopic shift and IOP elevation. Rise in macular thickness was similar in large and small capsulotomy groups. PMID:24724016

  5. Phacoemulsification with corneal astigmatism correction with the use of a toric intraocular lens in a case of megalocornea.

    PubMed

    Rękas, Marek; Pawlik, Rafał; Kluś, Adam; Różycki, Radosław; Szaflik, Jacek Paweł; Ołdak, Monika

    2011-08-01

    We report the case of a 49-year-old patient with megalocornea and coexisting corneal astigmatism. The corneal diameter in the right eye was 15.0 mm and in the left eye, 14.9 mm. In both eyes, a nuclear sclerotic cataract developed, with the tendency toward cortical mass swelling in the right eye. The aim of surgical treatment was to remove the cataract with simultaneous correction of corneal astigmatism by implanting an Acrysof toric intraocular lens (IOL). Intraocular lens stabilization was obtained by suturing it to an capsular tension ring (CTR) in the anterior chamber. The IOL-CTR complex was rotated into the lens capsule and aligned with the steep meridian of corneal astigmatism. The surgical technique provides a stable refractive and functional effect in patients with megalocornea and coexisting cataract and corneal astigmatism. PMID:21782100

  6. Accuracy of Intraocular Lens Power Formulas Involving 148 Eyes with Long Axial Lengths: A Retrospective Chart-Review Study.

    PubMed

    Chen, Chong; Xu, Xian; Miao, Yuyu; Zheng, Gaoxin; Sun, Yong; Xu, Xun

    2015-01-01

    Purpose. This study aims to compare the accuracy of intraocular lens power calculation formulas in eyes with long axial lengths from Chinese patients subjected to cataract surgery. Methods. A total of 148 eyes with an axial length of >26 mm from 148 patients who underwent phacoemulsification with intraocular lens implantation were included. The Haigis, Hoffer Q, Holladay 1, and SRK/T formulas were used to calculate the refractive power of the intraocular lenses and the postoperative estimated power. Results. Overall, the Haigis formula achieved the lowest level of median absolute error 1.025 D (P < 0.01 for Haigis versus each of the other formulas), followed by SRK/T formula (1.040 D). All formulas were least accurate when eyes were with axial length of >33 mm, and median absolute errors were significantly higher for those eyes than eyes with axial length = 26.01-30.00 mm. Absolute error was correlated with axial length for the SRK/T (r = 0.212, P = 0.010) and Hoffer Q (r = 0.223, P = 0.007) formulas. For axial lengths > 33 mm, eyes exhibited a postoperative hyperopic refractive error. Conclusions. The Haigis and SRK/T formulas may be more suitable for calculating intraocular lens power for eyes with axial lengths ranging from 26 to 33 mm. And for axial length over 33 mm, the Haigis formula could be more accurate. PMID:26793392

  7. Intraocular surgery in a large diabetes patient population: risk factors and surgical results.

    PubMed

    Ostri, Christoffer

    2014-05-01

    The prevalence of diabetes is on the increase in developed countries. Accordingly, the prevention and treatment of vision-threatening diabetic eye complications is assuming greater importance. The overall aim of this thesis is to analyse risk factors for intraocular surgery in a large diabetes population and to report surgical results. The specific objectives are to (1) estimate the incidence of diabetic vitrectomy and analyse risk factors (Study I), (2) report long-term results, prognostic factors and incidence of cataract surgery after diabetic vitrectomy (Study II), (3) report results and prognostic factors after cataract surgery in diabetes patients (Study III) and (4) analyse risk factors for diabetic papillopathy with emphasis on metabolic control variability (Study IV). All studies are based on a close-to-complete national surgery register and a large, closely followed diabetic retinopathy screening population. Study I (cohort study, 3980 type 1 diabetes patients) illustrates that diabetic vitrectomy is rarely required in a diabetes patient population with varying degrees of diabetic retinopathy. The risk of reaching diabetic vitrectomy increases fourfold with poor metabolic control, defined as glycosylated haemoglobin A1c > 75 mmol/mol (~9%), which points to good metabolic control as an important preventive measure. Study II (cohort study, 167 diabetes patients) shows that most diabetic vitrectomy patients stand to gain visual acuity ≥0.3 after surgery. Visual acuity is stable after 1 year, and the stability is maintained through 10 years of follow-up. The use of silicone oil for endotamponade is a consistent long-term predictor of low vision after surgery. The risk of requiring cataract surgery after diabetic vitrectomy is substantial, and the risk increases if silicone oil is used. Study III (cohort study, 285 diabetes patients) shows, on the other hand, that diabetes patients can expect a significant improvement in visual acuity after cataract

  8. Expression and Activation of STAT3 in the Astrocytes of Optic Nerve in a Rat Model of Transient Intraocular Hypertension

    PubMed Central

    Zhang, Shaodan; Li, Weiyi; Wang, Wenqian; Zhang, Samuel S.; Huang, Ping; Zhang, Chun

    2013-01-01

    Lamina cribosa, an astrocyte-rich region, is the origin of axonal degeneration in glaucomatous neuropathy. Astrocytes are particularly activated during optic nerve (ON) degeneration and are likely to contribute to the pathogenesis of glaucomatous optic neuropathy. Signalling mechanisms that regulate different aspects of astrocyte reactiviation in response to intraocular hypertensive injury are not well defined. Signal transducer and activator of transcription protein-3 (STAT3) is a transcription factor that participates in many biological processes and has been implicated as activator of reactive astrogliosis. In this study, we investigated the role of STAT3 in regulating the activation of astrocytes to transient intraocular hypertension in vivo by using a rat ocular hypertension model. ON astrocytes hypertrophy was observed early after intraocular hypertensive stress. Morphological changes in glial fibrillary acidic protein (GFAP) positive cells coupled with axon loss in the optic nerve was detected at day 7 after the injury. Nestin was significantly upregulated in ON astrocytes as early as day 2 post injury and kept elevated through post injury day 7. Phosphorylated STAT3 (pSTAT3) was markedly upregulated in ON astrocytes at post injury day 1, prior to the reactivation of ON astrocytes. These findings indicate that STAT3 signalling is involved in the initiation of astrocyte reactivation in optic nerve injury. PMID:23383263

  9. Long-term visual outcomes after Crystalens® HD intraocular lens implantation

    PubMed Central

    Karavitaki, Alexandra E; Pallikaris, Ioannis G; Panagopoulou, Sophia I; Kounis, George A; Kontadakis, George; Kymionis, George D

    2014-01-01

    Purpose Our purpose was to evaluate the long-term visual outcomes after bilateral implantation of Crystalens® HD (Bausch and Lomb, Inc.) accommodative intraocular lenses. Methods In this study, 25 patients (50 eyes) who underwent cataract surgery and bilateral Crystalens HD accommodative intraocular lens implantation were included. The Crystalens HD lens was implanted in the bag in both eyes, without any intra- or postoperative complications. The visual parameters measured before and after surgery were: uncorrected distance visual acuity, corrected distance visual acuity (CDVA) (using the Early Diabetic Retinopathy Study [EDTRS] logMAR charts), uncorrected intermediate visual acuity, and uncorrected near visual acuity using a Birkhäuser reading chart, at a distance of 66 cm and 33 cm for intermediate and near vision, respectively, directly illuminated by a lamp of 60 watts. After surgery, the patients were evaluated at 1, 3, 6, 12, 24, and 36 months. Results The mean age was 68.70±7.1 (range: 54 to 83) years. The mean follow-up was 42.72±0.49 (range: 42.33 to 43.27) months. The uncorrected distance visual acuity improved from 0.56±0.41 (range: 0 to 2) preoperatively to 0.19±0.13 (range: 0 to 0.38) (logMAR scale) at the last follow-up visit, and the CDVA improved from 0.17±0.18 (range: 0 to 0.7) preoperatively to 0.05±0.05 (range: −0.02 to 0.22) at the last follow-up visit. No eyes lost lines of CDVA during the follow-up period, while 54% of patients gained one or more lines of CDVA. The uncorrected intermediate and near visual acuity was J2 or better in 71% and 69% of our patients, respectively. Conclusion Crystalens HD implantation seems to provide an improvement in visual acuity for far, intermediate, and near distances. PMID:24899793

  10. Chronic Low Level Complement Activation within the Eye Is Controlled by Intraocular Complement Regulatory Proteins

    PubMed Central

    Sohn, Jeong-Hyeon; Kaplan, Henry J.; Suk, Hye-Jung; Bora, Puran S.; Bora, Nalini S.

    2007-01-01

    Purpose To explore the role of the complement system and complement regulatory proteins in an immune-privileged organ, the eye. Methods Eyes of normal Lewis rats were analyzed for the expression of complement regulatory proteins, membrane cofactor protein (MCP), decay-acceleration factor (DAF), membrane inhibitor of reactive lysis (MIRL, CD59), and cell surface regulator of complement (Crry), using immunohistochemistry, Western blot analysis, and reverse transcription–polymerase chain reaction (RT-PCR). Zymosan, a known activator of the alternative pathway of complement system was injected into the anterior chamber of the eye of Lewis rats. Animals were also injected intracamerally with 5 μl (25 μg) of neutralizing monoclonal antibody (mAb) against rat Crry (5I2) or CD59 (6D1) in an attempt to develop antibody induced anterior uveitis; control animals received 5 μl of sterile phosphate-buffered saline (PBS), OX-18 (25 μg), G-16-510E3 (25 μg), or MOPC-21 (25 μg). The role of complement system in antibody-induced uveitis was explored by intraperitoneal injection of 35 U cobra venom factor (CVF), 24 hours before antibody injection. Immunohistochemical staining and sodium dodecyl sulfate–polyacrylamide gel electrophoresis (SDS-PAGE) with Western blot analysis were used to detect the presence of membrane attack complex (MAC) and C3 activation products, respectively, in normal and antibody-injected rat eyes. Results Complement activation product MAC was present in the normal rat eye, and intraocular injection of zymosan induced severe anterior uveitis. The complement regulatory proteins, MCP, DAF, CD59, and Crry, were identified in the normal rat eye. Soluble forms of Crry and CD59 were also detected in normal rat aqueous humor. Severe anterior uveitis developed in Lewis rats injected with a neutralizing mAb against Crry, with increased formation of C3 split products. Systemic complement depletion by CVF prevented the induction of anterior uveitis by anti

  11. Corneal biomechanical changes and intraocular pressure in patients with thyroid orbitopathy

    PubMed Central

    Pniakowska, Zofia; Klysik, Anna; Gos, Roman; Jurowski, Piotr

    2016-01-01

    AIM To determine the relevance of the objective parameters addressing the altered biomechanical properties of cornea for glaucoma monitoring in patients with mild or moderate thyroid associated orbitopathy (TAO), and in healthy individuals. METHODS Twenty-five patients with TAO (group 1) and 25 healthy adults (group 2) were included to the study. Both groups were of a similar age and the ratio women:man. For each patient, the following parameters of both eyes were measured with ocular response analyzer (ORA): corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann correlated intraocular pressure (IOPg) and corneal compensated intraocular pressure (IOPcc). In both groups participating in our study, all measurements were performed within minutes to reduce the diurnal effects. RESULTS The mean age in group 1 was 56±11y and 76% were women, 24% were men. The mean age in group 2 was 64±11y and 68% were women, 32% were men. CH correlated negatively with IOPg in group 1 (r2=0.10, P<0.05). IOPg strongly correlated with IOPcc in both groups (group 1: r2=0.79, P<0.0001; group 2: r2=0.85, P<0.0001). There was positive correlation between CRF and IOPg in group 1 (r2=0.12, P<0.05) and in group 2 (r2=0.31, P<0.0001). Statistical analysis revealed no significant correlation between CRF and IOPcc in group 1 (r2=0.009, P>0.05) and also no significant correlation in group 2 (r2=0.04, P>0.05). CRF mean value in group 2 (11.51±1.72 mm Hg) was higher than in group 1 (10.85±1.45 mm Hg) (P<0.05). IOPg strongly correlated with IOPcc in both groups (group 1: r2=0.79, P<0.0001; group 2: r2=0.85, P<0.0001). There was also strong correlation between CRF and CH in both populations: group 1: (r2=0.58, P<0.0001), group 2: (r2=0.41, P<0.0001). CONCLUSION Biomechanical parameters of cornea, as quantified by CH and CRF, and measured together with IOPcc, precisely reveal glaucoma staging in TAO and thus are reliable for diagnosing and follow-up in clinical practice. PMID:27158617

  12. Long-Term Visual Outcomes of Secondary Intraocular Lens Implantation in Children with Congenital Cataracts

    PubMed Central

    Jiang, Yongxiang; Lu, Yi

    2015-01-01

    Aim The aim of this study was to evaluate the long-term visual outcomes and factors affecting visual results in children undergoing secondary intraocular lens (IOL) implantation following primary congenital cataract extraction. Methods Children with congenital cataracts who underwent secondary IOL implantation for aphakia at the Eye and ENT Hospital of Fudan University between January 1, 2001, and December 31, 2007, were retrospectively reviewed. One eye was randomly selected in children with bilateral cataracts. Laterality, type of cataract (total or partial opacity), sex, age at primary and secondary surgeries, visual axis opacity (VAO), compliance with amblyopia therapy, postoperative ocular complications, refractive error, ocular alignment, and best corrected visual acuity (BCVA) at last follow-up were recorded; potential factors that might have affected the visual results were evaluated. Results Seventy-six bilateral and 34 unilateral congenital cataract cases were analyzed; the mean ages of the children were 12.70±5.06 and 12.50±2.71 years at final follow-up, the mean follow-up periods from IOL implantation were 94.93±24.22 and 109.09±18.89 months, and the mean BCVA (Log MAR) values were 0.51±0.37 and 1.05±0.46, respectively. Final BCVA after secondary IOL implantation was significantly associated with laterality, type of cataract, age at primary cataract extraction, compliance with amblyopia therapy, and refractive correction after surgery. No significant associations were found between BCVA and sex, age at secondary IOL implantation, VAO, or other ocular complications. The most common ocular complications were VAO and elevated intraocular pressure after surgery. There were no other complications, with the exception of one eye with IOL dislocation. Conclusions The results indicate that the important determinants of long-term visual outcomes in children with congenital cataracts undergoing secondary IOL implantation are laterality, cataract type, age at

  13. Infection and Cardiovascular Disease

    ClinicalTrials.gov

    2016-02-17

    Cardiovascular Diseases; Coronary Disease; Cerebrovascular Accident; Heart Diseases; Myocardial Infarction; Infection; Chlamydia Infections; Cytomegalovirus Infections; Helicobacter Infections; Atherosclerosis

  14. The Application of a Contact Lens Sensor in Detecting 24-Hour Intraocular Pressure-Related Patterns

    PubMed Central

    2016-01-01

    Glaucoma is one of the leading causes of blindness worldwide. Recent studies suggest that intraocular pressure (IOP) fluctuations, peaks, and rhythm are important factors in disease advancement. Yet, current glaucoma management remains hinged on single IOP measurements during clinic hours. To overcome this limitation, 24-hour IOP monitoring devices have been employed and include self-tonometry, permanent IOP, and temporary IOP monitoring. This review discusses each IOP measuring strategy and focuses on the recently FDA-approved contact lens sensor (CLS). The CLS records IOP-related ocular patterns for 24 hours continuously. Using the CLS, IOP-related parameters have been found to be associated with the rate of visual field progression in primary open-angle glaucoma, disease progression in primary angle-closure glaucoma, and various clinical variables in ocular hypertension. The CLS has been used to quantify blink rate and limbal strain and measure the circadian rhythm in a variety of disease states including normal-tension glaucoma and thyroid eye disease. The effects of various IOP-lowering interventions were also characterized using the CLS. CLS provides a unique, safe, and well-tolerated way to study IOP-related patterns in a wide range of disease states. IOP-related patterns may help identify patients most at risk for disease progression and assist with the development of tailored treatments. PMID:27525110

  15. Intraocular BDNF Promotes Ectopic Branching, Alters Motility and Stimulates Abnormal Collaterals in Regenerating Optic Fibers

    PubMed Central

    Dawson, Amy J.; Miotke, Jill A.; Meyer, Ronald L.

    2015-01-01

    A great deal of effort has been invested in using trophic factors and other bioactive molecules to promote cell survival and axonal regeneration in the adult central nervous system. Far less attention has been paid to investigating potential effects that trophic factors may have that might interfere with recovery. In the visual system, BDNF has been previously reported to prevent regeneration. To test if BDNF is inherently incompatible with regeneration, BDNF was given intraocularly during optic nerve regeneration in the adult goldfish. In vivo imaging and anatomical analysis of selectively labeled axons were used as a sensitive assay for effects on regeneration within the tectum. BDNF had no detectable inhibitory effect on the ability of axons to regenerate. Normal numbers of axons regenerated into the tectum, exhibited dynamic growth and retractions similar to controls, and were able to navigate to their correct target zone in the tectum. However, BDNF was found to have additional effects that adversely affected the quality of regeneration. It promoted premature branching at ectopic locations, diminished the growth rate of axons through the tectum, and resulted in the formation of ectopic collaterals. Thus, although BDNF has robust effects on axonal behavior, it is, nevertheless, compatible with axonal regeneration, axon navigation and the formation of terminal arbors. PMID:25847715

  16. INTRAOCULAR PRESSURE IN SOUTHERN ROCKHOPPER (EUDYPTES CHRYSOCOME) AND MACARONI PENGUINS (EUDYPTES CHRYSOLOPHUS): EVALUATION OF INFLUENCING FACTORS.

    PubMed

    Woodhouse, Sarah J; Peterson, Edward L; Schmitt, Todd; Aquino, Susette

    2016-03-01

    Ophthalmic examinations were performed on 160 macaroni penguins (Eudyptes chrysolophus) and 90 southern rockhopper penguins (Eudyptes chrysocome) at eight North American zoos and aquaria. Intraocular pressure (IOP) was measured using rebound tonometry while penguins were held in two different body positions. Correlations between IOP and factors including age, body position, eye pathology, and housing parameters were evaluated. Normal macaroni penguins had a mean IOP of 42.0 ± 9.7 mm Hg. Normal rockhopper penguins had a mean IOP of 32.9 ± 6.2 mm Hg. Neither species had significantly different IOP between sexes or between left and right eyes of the same penguin. In both species, there was a negative linear correlation between age and IOP. In the macaroni population, IOP was significantly higher when IOP measurement was performed before ophthalmic exam; this was not true in rockhoppers. In both species, IOP measured in a horizontal body position was significantly higher than IOP measured in a vertical body position. In both species, eyes with corneal lesions had significantly lower IOP than normal eyes. In the macaroni penguin, eyes with rubeosis iridis had significantly lower IOP than normal eyes. In macaroni penguins, eyes with cataracts had significantly lower mean IOP than normal eyes; this was not true for rockhoppers. PMID:27010282

  17. Association between Glucose Levels and Intraocular Pressure: Pre- and Postprandial Analysis in Diabetic and Nondiabetic Patients

    PubMed Central

    Pimentel, Luis Guilherme Milesi; Gracitelli, Carolina P. B.; da Silva, Leticia Sant'Ana Cardoso; Souza, Aline Katia Siqueira; Prata, Tiago Santos

    2015-01-01

    The aim of this study was to evaluate the relationship between glucose levels and intraocular pressure (IOP) fluctuation in diabetic and nondiabetic patients. Seventeen nondiabetic and 20 diabetic subjects underwent a complete ophthalmic examination, capillary glucose testing, and applanation tonometry in two distinct situations: first, fasting for at least 8 hours and, second, postprandial measurements. Baseline glucose levels were higher in diabetic patients (P < 0.001). Postprandial IOP was significantly higher than baseline IOP in diabetic (P < 0.001) and nondiabetic patients (P = 0.006). Postprandial glucose levels were significantly higher than baseline measurements in both diabetic (P = 0.005) and nondiabetic patients (P = 0.015). There was a significant association between glucose levels variation and IOP change in both diabetic patients (R2 = 0.540; P < 0.001) and nondiabetic individuals (R2 = 0.291; P = 0.025). There is also a significant association between the baseline glucose levels and IOP change in diabetic group (R2 = 0.445; P = 0.001). In a multivariable model, the magnitude of glucose level change remained significantly associated with IOP variation even including age, baseline IOP, ancestry, and gender as a confounding factor (P < 0.001). We concluded that there is a significant association between blood glucose levels and IOP variation, especially in diabetic patients. PMID:25642344

  18. Regulation of intraocular pressure by soluble and membrane guanylate cyclases and their role in glaucoma

    PubMed Central

    Buys, Emmanuel S.; Potter, Lincoln R.; Pasquale, Louis R.; Ksander, Bruce R.

    2014-01-01

    Glaucoma is a progressive optic neuropathy characterized by visual field defects that ultimately lead to irreversible blindness (Alward, 2000; Anderson et al., 2006). By the year 2020, an estimated 80 million people will have glaucoma, 11 million of which will be bilaterally blind. Primary open-angle glaucoma (POAG) is the most common type of glaucoma. Elevated intraocular pressure (IOP) is currently the only risk factor amenable to treatment. How IOP is regulated and can be modulated remains a topic of active investigation. Available therapies, mostly geared toward lowering IOP, offer incomplete protection, and POAG often goes undetected until irreparable damage has been done, highlighting the need for novel therapeutic approaches, drug targets, and biomarkers (Heijl et al., 2002; Quigley, 2011). In this review, the role of soluble (nitric oxide (NO)-activated) and membrane-bound, natriuretic peptide (NP)-activated guanylate cyclases that generate the secondary signaling molecule cyclic guanosine monophosphate (cGMP) in the regulation of IOP and in the pathophysiology of POAG will be discussed. PMID:24904270

  19. Scleral Fixation of Posteriorly Dislocated Intraocular Lenses by 23-Gauge Vitrectomy without Anterior Segment Approach

    PubMed Central

    Nadal, Jeroni; Kudsieh, Bachar; Casaroli-Marano, Ricardo P.

    2015-01-01

    Background. To evaluate visual outcomes, corneal changes, intraocular lens (IOL) stability, and complications after repositioning posteriorly dislocated IOLs and sulcus fixation with polyester sutures. Design. Prospective consecutive case series. Setting. Institut Universitari Barraquer. Participants. 25 eyes of 25 patients with posteriorly dislocated IOL. Methods. The patients underwent 23-gauge vitrectomy via the sulcus to rescue dislocated IOLs and fix them to the scleral wall with a previously looped nonabsorbable polyester suture. Main Outcome Measures. Best corrected visual acuity (BCVA) LogMAR, corneal astigmatism, endothelial cell count, IOL stability, and postoperative complications. Results. Mean follow-up time was 18.8 ± 10.9 months. Mean surgery time was 33 ± 2 minutes. Mean BCVA improved from 0.30 ± 0.48 before surgery to 0.18 ± 0.60 (p = 0.015) at 1 month, which persisted to 12 months (0.18 ± 0.60). Neither corneal astigmatism nor endothelial cell count showed alterations 1 year after surgery. Complications included IOL subluxation in 1 eye (4%), vitreous hemorrhage in 2 eyes (8%), transient hypotony in 2 eyes (8%), and cystic macular edema in 1 eye (4%). No patients presented retinal detachment. Conclusion. This surgical technique proved successful in the management of dislocated IOL. Functional results were good and the complications were easily resolved. PMID:26294964

  20. Effect of the color of the intraocular lens on optical and visual quality

    PubMed Central

    Díez-Ajenjo, Mª Amparo; García-Domene, Mª Carmen; Peris-Martínez, Cristina; Artigas, José Mª; Felipe, Adelina

    2014-01-01

    Purpose: To analyze the optical quality of intraocular lenses (IOL) with an orange (PC440Y) and a yellow (SN60AT) filter, and correlate these results with the visual quality of patients with these implants. Setting: Fisabio Oftalmología Médica, Valencia, Spain. Design: Randomized prospective study. Materials and Methods: The IOL optical quality was determined using the modulation transfer function (MTF) and the spectral transmission. The visual quality of 87 eyes with cataract (51 with orange filter and 36 with yellow filter) was determined by best corrected visual acuity (BCVA) and contrast sensitivity function (CSF) under photopic and mesopic conditions. To analyze the results, we use a Student's t-test. Results: Orange lens filtered more of the blue spectrum (cut-off wavelength of 370 nm) than the yellow lens (390 nm). The MTF of the yellow lens was better than the orange lens (average modulation of 0.676 for natural and 0.672 for orange). The patients’ BCVA was 0.02 + 0.10 logMAR for both lenses. The CSF obtained with the yellow lens was slightly better, although without statistically significant differences (P > 0.05). Conclusions: Both lenses are of good optical quality. The patients’ visual quality was similar with both lenses, and optical quality was also similar. The color of the lens does not affect the visual quality of the patient. PMID:25494247

  1. Evaluation of a class of polyurethane materials for intraocular lens manufacturing.

    PubMed

    Bozukova, Dimitriya; Bertrand, Virginie; Pagnoulle, Christophe; De Pauw-Gillet, Marie-Claire

    2015-08-01

    Ophthalmic lenses are medical devices with considerable requirements in terms of optical, biomechanical and biological performance. There is limited number of materials used for their manufacturing, comprising mainly silicones and poly(meth)acrylates. This series of publications aims at investigating the applicability of thermoplastic polyurethane elastomers (TPU) for the manufacturing of ophthalmic lenses and examining the properties of the respective devices. This study is related to the synthesis of TPUs with chemical compositions that comprise chemically grafted filters for the hazardous-light. GC-MS, attenuated total reflectance Fourier transform infrared spectroscopy, and UV-vis spectroscopies confirmed the reaction completion and the beneficial effect of the filters on the light transmittance, respectively. Relatively high refractive index of the material was measured and allows for the manufacturing of thinner lenses. The contrast sensitivity determined for a model intraocular lens (IOL) was satisfactory. Few optical defects were, however, present on the model lens prepared by thermoplastic injection molding. The elasticity of the materials was evaluated in view to their potential applicability as foldable IOLs by determining their glass transition temperature and their Young modulus and measuring their shore A. The TPU materials demonstrated more bioadhesive character compared with a benchmark hydrophilic acrylic reference material, which is already used for IOL manufacturing. PMID:25352276

  2. Toric intraocular lenses for correction of astigmatism in keratoconus and after corneal surgery

    PubMed Central

    Mol, Ilse EMA; Van Dooren, Bart TH

    2016-01-01

    Purpose To describe the results of cataract extraction with toric intraocular lens (IOL) implantation in patients with preexisting astigmatism from three corneal conditions (keratoconus, postkeratoplasty, and postpterygium surgery). Methods Cataract patients with topographically stable, fairly regular (although sometimes very high) corneal astigmatism underwent phacoemulsification with implantation of a toric IOL (Zeiss AT TORBI 709, Alcon Acrysof IQ toric SN6AT, AMO Tecnis ZCT). Postoperative astigmatism and refractive outcomes, as well as visual acuities, vector reduction, and complications were recorded for all eyes. Results This study evaluated 17 eyes of 16 patients with a mean age of 60 years at the time of surgery. Mean follow-up in this study was 12 months. The corrected distance Snellen visual acuity (with spectacles or contact lenses) 12 months postoperatively was 20/32 or better in 82% of eyes. The mean corneal astigmatism was 6.7 diopters (D) preoperatively, and 1.5 D of refractive cylinder at 1-year follow-up. No vision-compromising intra- or postoperative complications occurred and decentration or off-axis alignment of toric IOLs were not observed. Conclusion Phacoemulsification with toric IOL implantation was a safe and effective procedure in the three mentioned corneal conditions. Patient selection, counseling, and IOL placement with optimal astigmatism correction are crucial. PMID:27382249

  3. Biological performance of functionalized biomedical polymers for potential applications as intraocular lens.

    PubMed

    Zheng, Zhiwen; Wang, Yingjun; Jiao, Yan; Zhai, Zhichen

    2016-08-01

    To study the biological performance of surface-modified biomedical polymer materials, a model of the functional mechanism of nonspecific adsorption resistance was constructed. Cell behavior on the surface and in vivo transplantation features of intraocular lens (IOL) materials, such as hydrophobic acrylic ester and polymethyl methacrylate (PMMA), were investigated. The results of cell adhesion and proliferation studies showed that the addition of hirudin can significantly resist epithelial cell adhesion, better than the pure amination process, and thereby inhibit excessive proliferation on the surface. Experiments on the eyes of rabbits indicated that the IOL surfaces with hirudin modification reduced the incidence of cell aggregation and inflammation. Combined with a study of protein-resistant layer construction with recombinant hirudin on the material surface, the mechanism of surface functionalization was determined. The biological performance indicated that nonspecific adsorption is greatly decreased due to the existence of amphiphilic ions or hydration layers, which lead to stability and long-term resistance to nonspecific adsorption. These results offer a theoretical basis for the use of traditional biomedical polymer materials in long-term clinical applications. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 1961-1967, 2016. PMID:27027387

  4. Differences of Longitudinal Chromatic Aberration (LCA) between Eyes with Intraocular Lenses from Different Manufacturers

    PubMed Central

    Nakajima, Masashi; Hiraoka, Takahiro; Yamamoto, Toshiya; Takagi, Seiu; Hirohara, Yoko; Oshika, Tetsuro

    2016-01-01

    Several researchers have studied the longitudinal chromatic aberration (LCA) of eyes implanted with an intraocular lens (IOL). We investigated the LCA of eyes implanted with yellow-colored IOLs from three different manufacturers: Alcon Inc., HOYA Corp., and AMO Inc. The number of subjects was 11, 16, and 16, respectively. The LCA of eyes implanted with SN60WF and SN60AT (Alcon Inc.), and with XY-1 (HOYA Corp.), was the same as that of phakic eyes. The LCA of eyes with ZCB00V (AMO Inc.) was smaller than that of phakic eyes. The LCA of eyes implanted with Alcon’s and HOYA’s IOLs, but not the LCA of eyes implanted with AMO’s IOLs, was positively correlated with the powers of the IOLs. We also performed simulations to verify the impacts of LCA on visual performance for 4-mm pupil diameter; the simulations were a polychromatic modulation transfer function (MTF) and a visual Strehl ratio computed on the basis of an optical transfer function (VSOTF). We concluded that the differences between the LCA of different manufacturers do not affect visual performances when some extent of higher-order aberration (HOA) exists. The smaller HOA of AMO IOLs may enhance visual performance. PMID:27258141

  5. Instrumental studies on silicone oil adsorption to the surface of intraocular lenses

    NASA Astrophysics Data System (ADS)

    Kim, Chun Ho; Joo, Choun-Ki; Chun, Heung Jae; Yoo, Bok Ryul; Noh, Dong Il; Shim, Young Bock

    2012-12-01

    The purpose of this study was to examine the degree of adherence of silicone oil to various intraocular lenses (IOLs) through comparison of the physico-chemical properties of the oil and IOLs. Four kinds of IOLs comprising various biomaterials were examined: PMMA (720A™), PHEMA (IOGEL 1103™), Acrysof (MA60BM™), and silicone (SI30NB™). Each lens was immersed in silicone oil or carboxylated silicone (CS-PDMS) oil for 72 h. For determination of the changes in chemical and elemental compositions on the surfaces of IOLs caused by the contact with silicone oil, IOLs were washed and rinsed with n-pentane to remove as much of the adsorbed silicone oil as possible, then subjected to Fourier transform infrared spectroscopic (FTIR) and X-ray photoelectron spectroscopic (XPS) analyses. The results of FTIR studies strongly indicate that washing with n-pentane completely removed the adhered silicone oil on the surfaces of PHEMA and Acrysof IOLs, whereas the residual silicone oil was detected on the surfaces of PMMA and silicone IOLs. XPS studies showed that silicone oil coverage of PMMA lenses was 12%, even after washing with n-pentane. In the case of silicone IOLs, the relative O1s peak area of carboxyl group in the residual CS-PDMS oil was found to be ˜2.7%. Considering that 2.8% carboxyl group-substituted silicone oil was used in the present study, CS-PDMS oil covered the entire surface of the silicone IOLs.

  6. Dynamic response of intraocular pressure and biomechanical effects of the eye considering fluid-structure interaction.

    PubMed

    Salimi, S; Park, S Simon; Freiheit, T

    2011-09-01

    The vibration characteristics of shell structures such as eyes have been shown to vary with intraocular pressure (IOP). Therefore, vibration characteristics of the eye have the potential to provide improved correlation to IOP over traditional IOP measurements. As background to examine an improved IOP correlation, this paper develops a finite element model of an eye subject to vibration. The eye is modeled as a shell structure filled with inviscid pressurized fluid in which there is no mean flow. This model solves a problem of a fluid with coupled structural interactions of a generally spherically shaped shell system. The model is verified by comparing its vibrational characteristics with an experimental modal analysis of an elastic spherical shell filled with water. The structural dynamic effects due to change in pressure of the fluid are examined. It is shown that the frequency response of this fluid-solid coupled system has a clear increase in natural frequency as the fluid pressure rises. The fluid and structure interaction is important for accurate prediction of system dynamics. This model is then extended to improve its accuracy in modeling the eye by including the effect of the lens to study corneal vibration. The effect of biomechanical parameters such as the thicknesses of different parts of the eye and eye dimensions in altering measured natural frequencies is investigated and compared to the influence of biomechanical parameters in Goldmann applanation tonometry models. The dynamic response of the eye is found to be less sensitive to biomechanical parameters than the applanation tonometry model. PMID:22010744

  7. The impact of multifocal intraocular lens in retinal imaging with optical coherence tomography.

    PubMed

    Dias-Santos, Arnaldo; Costa, Lívio; Lemos, Vanessa; Anjos, Rita; Vicente, André; Ferreira, Joana; Cunha, João Paulo

    2015-02-01

    Multifocal intraocular lenses (MF IOLs) have concentric optical zones with different dioptric power, enabling patients to have good visual acuity at multiple focal points. However, several optical limitations have been attributed to this particular design. The purpose of this study is to access the effect of MF IOLs design on the accuracy of retinal optical coherence tomography (OCT). Cross-sectional study conducted at the Refractive Surgery Department of Central Lisbon Hospital Center. Twenty-three eyes of 15 patients with a diffractive MF IOL and 27 eyes of 15 patients with an aspheric monofocal IOL were included in this study. All patients underwent OCT macular scans using Heidelberg Spectralis(®). Macular thickness and volume values and image quality (Q factor) were compared between the two groups. There were no statistically significant differences between both groups regarding macular thickness or volume measurements. Retinal OCT image quality was significantly lower in the MF IOL group (p < 0.01). MF IOLs are associated with a significant decrease in OCT image quality. However, this fact does not seem to compromise the accuracy of spectral domain OCT retinal measurements. PMID:25381578

  8. Visual and Refractive Outcomes of a Toric Presbyopia-Correcting Intraocular Lens.

    PubMed

    Epitropoulos, Alice T

    2016-01-01

    Purpose. To evaluate outcomes in astigmatic patients implanted with the Trulign (Bausch + Lomb) toric presbyopia-correcting intraocular lens (IOL) during cataract surgery in a clinical practice setting. Methods. Retrospective study in 40 eyes (31 patients) that underwent cataract extraction and IOL implantation in a procedure using intraoperative wavefront aberrometry guidance (ORA system). Endpoints included uncorrected visual acuity (VA), reduction in refractive cylinder, accuracy to target, axis orientation, and safety. Results. At postoperative month 1, refractive cylinder was ≤0.50 D in 97.5% of eyes (≤1.00 D in 100%), uncorrected distance VA was 20/25 or better in 95%, uncorrected intermediate VA was 20/25 or better in 95%, and uncorrected near VA was 20/40 (J3 equivalent) or better in 92.5%. Manifest refraction spherical equivalent was within 1.00 D of target in 95% of eyes and within 0.50 D in 82.5%. Lens rotation was <5° and best-corrected VA was 20/25 or better in all eyes. Conclusion. The IOL effectively reduced refractive cylinder and provided excellent uncorrected distance and intermediate vision and functional near vision. Refractive predictability and rotational stability were exceptional. Implantation of this toric presbyopia-correcting IOL using ORA intraoperative aberrometry provides excellent refractive and visual outcomes in a standard of care setting. PMID:26885382

  9. Visual and Refractive Outcomes of Phacoemulsification with Implantation of Accommodating versus Standard Monofocal Intraocular Lenses

    PubMed Central

    Sadoughi, Mohammad Mehdi; Einollahi, Bahram; Roshandel, Danial; Sarimohammadli, Mohammad; Feizi, Sepehr

    2015-01-01

    Purpose: To compare distant and near visual function after cataract surgery with implantation of Crystalens HD or Tek-Clear as accommodating intraocular lenses (IOLs), versus SA60AT as a standard IOL. Methods: The study included 62 eyes of 58 patients divided into three groups using three different IOLs: Crystalens HD (Bausch and Lomb, NY, USA), Tek-Clear (Tekia, CA, USA) and SA60AT (Alcon, TX, USA) were implanted in 23, 14 and 25 eyes, respectively. Corrected distant visual acuity (CDVA), uncorrected and distance corrected near visual acuities (UCNVA and DCNVA), near point of accommodation (NPA), spectacle freedom and patient satisfaction were assessed six months postoperatively and compared between the three groups. Results: After 6 months, all patients showed significant improvement in CDVA with no significant difference among the study groups. However, UCNVA and DCNVA were significantly better in patients implanted with accommodating IOLs. NPA was closest in the Crystalens HD group, followed by Tek-Clear and monofocal SA60AT (P < 0.001). Patients with accommodating IOLs were more likely to become spectacle free and satisfied with their near vision as compared to subjects receiving a monofocal IOL. Conclusions: Accommodating IOLs (Crystalens HD and Tek-Clear) effectively reduce the necessity for spectacles after cataract surgery. PMID:27051480

  10. Effects of betaxolol and flunarizine on visual fields and intraocular pressure in patients with migraine.

    PubMed

    Yarangümeli, Alper; Comoglu, Selçuk; Köz, Ozlem Gürbüz; Elhan, Atilla Halil; Kural, Gülcan

    2003-05-01

    Fifty-one patients with migraine were divided into four groups to investigate the effects of topical betaxolol and systemic calcium channel blocker flunarizine on visual fields (VF) and intraocular pressure (IOP). The first group (Group 0) was followed with no medications, topical betaxolol (bid) was precribed to the second group (Group B), oral flunarizine (10 mg daily) was prescribed to the third group (Group F), and the last group (Group BF) was assigned for combined betaxolol and flunarizine treatment. After a mean follow-up time of 4.2 +/- 1.2 months (3-6 months), IOP measurements and VF tests were repeated. Group B and Group BF were found to be statistically different from the other groups in terms of IOP reduction and VF improvement according to mean deviation and corrected pattern standard deviation indices in the second examinations. On the other hand, Group F and Group BF differed from the other two groups considering the improvement in migrainous complaints. VF findings which are probably influenced by perfusion problems due to vasospastic mechanisms in migraineurs, improved following topical betaxolol treatment. However, systemic use of flunarizine--a calcium channel blocker--did not seem to be effective on visual fields although it had beneficial effects on migraine. PMID:12737504

  11. Elevated Intraocular Pressure Induces Rho GTPase Mediated Contractile Signaling in the Trabecular Meshwork

    PubMed Central

    Pattabiraman, Padmanabhan P; Inoue, Toshihiro; Rao, P. Vasantha

    2015-01-01

    Rho GTPase regulated contractile signaling in the trabecular meshwork (TM) has been shown to modulate aqueous humor (AH) outflow and intraocular pressure (IOP). To explore whether elevated IOP, a major risk factor for primary open angle glaucoma (POAG) influences Rho GTPase signaling in the TM, we recorded AH outflow in enucleated contralateral porcine eyes perfused for 4–5 hours at either 15 mm or 50 mm Hg pressure. After perfusion, TM tissue extracted from perfused eyes was evaluated for the activation status of Rho GTPase, myosin light chain (MLC), myosin phosphatase target substrate 1 (MYPT1), myristoylated alanine-rich C-kinase substrate (MARCKS) and paxillin. Eyes perfused at 50 mm Hg exhibited a significant decrease in AH outflow facility compared with those perfused at 15 mm Hg. Additionally, TM tissue from eyes perfused at 50 mm Hg revealed significantly increased levels of activated RhoA and phosphorylated MLC, MYPT1, MARCKS and paxillin compared to TM tissue derived from eyes perfused at 15 mm Hg. Taken together, these observations indicate that elevated IOP-induced activation of Rho GTPase-dependent contractile signaling in the TM is associated with increased resistance to AH outflow through the trabecular pathway, and demonstrate the sensitivity of Rho GTPase signaling to mechanical force in the AH outflow pathway. PMID:25956210

  12. Intraocular pressure elevation after intravitreal triamcinolone acetonide injection: a Meta-analysis

    PubMed Central

    Yuksel-Elgin, Cansu; Elgin, Ceyhun

    2016-01-01

    AIM To report on intraocular pressure (IOP) after intravitreal injections of triamcinolone acetonide. METHODS Systematic literature review of studies that investigated the effects of an injection of triamcinolone intravitreal triamcinolone acetonide on IOP was conducted according to the Cochrane Collaboration methodology and the reported effects have been analyzed with Meta-analysis. RESULTS We found that the IOP follows an inverted-U shape pattern over time starting with an average value of 14.81±1.22 mm Hg before the injection, rising to a maximum of 19.48±2.15 mm Hg after one month of injection and falling down to 16.16±1.92 mm Hg after 6mo. Moreover, country of study, age, previous history of glaucoma and gender compositions matter for cross-study were different in reported IOP changes. CONCLUSION Our findings may be helpful in determining pressure elevation risk of intravitreal triamcinolone acetonide therapy as well as comparing it with those of more recent therapies such as the anti-vascular endothelial growth factor agents. PMID:26949624

  13. Modeling glaucoma in rats by sclerosing aqueous outflow pathways to elevate intraocular pressure.

    PubMed

    Morrison, John C; Cepurna, William O; Johnson, Elaine C

    2015-12-01

    Injection of hypertonic saline via episcleral veins toward the limbus in laboratory rats can produce elevated intraocular pressure (IOP) by sclerosis of aqueous humor outflow pathways. This article describes important anatomic characteristics of the rat optic nerve head (ONH) that make it an attractive animal model for human glaucoma, along with the anatomy of rat aqueous humor outflow on which this technique is based. The injection technique itself is also described, with the aid of a supplemental movie, including necessary equipment and specific tips to acquire this skill. Outcomes of a successful injection are presented, including IOP elevation and patterns of optic nerve injury. These concepts are then specifically considered in light of the use of this model to assess potential neuroprotective therapies. Advantages of the hypertonic saline model include a delayed and relatively gradual IOP elevation, likely reproduction of scleral and ONH stresses and strains that may be important in producing axonal injury, and its ability to be applied to any rat (and potentially mouse) strain, leaving the unmanipulated fellow eye as an internal control. Challenges include the demanding surgical skill required by the technique itself, a wide range of IOP response, and mild corneal clouding in some animals. However, meticulous application of the principles detailed in this article and practice will allow most researchers to attain this useful skill for studying cellular events of glaucomatous optic nerve damage. PMID:26003399

  14. Late opacification of a silicone intraocular lens caused by ophthalmic ointment.

    PubMed

    Chew, Jesse J L; Werner, Liliana; Mackman, Gary; Mamalis, Nick

    2006-02-01

    A 55-year-old man had uneventful phacoemulsification with implantation of a 3-piece silicone intraocular lens (IOL). Postoperative medications included antibiotic-steroid drops and ointments. Eight months postoperatively, the patient started having recurrent episodes of anterior chamber inflammatory reaction. Suspicion that lens instability was causing the reactions led to a lens repositioning procedure 11 months after the initial surgical implantation and again at 13 months. Eighteen months postoperatively, the IOL had a "greasy" film. Despite antiinflammatory and antibiotic treatment, the clinical outcome did not improve. Twenty-seven months after implantation, the lens was exchanged with a hydrophilic acrylic IOL. The course after the exchange was uneventful. The explanted lens was examined by gross and microscopic evaluations, scanning electron microscopy, energy-dispersive X-ray spectroscopy, and gas chromatography-mass spectrometry (GC-MS) using electronic ionization. Gross and microscopic evaluations confirmed the presence of a thin, oily film covering the IOL optic surface. Surface analyses at the level of the oily substance showed unspecific peaks of sodium, chloride, and potassium. The GC-MS analysis showed the presence of compounds characteristic of hydrocarbons, including docosane, tricosane, and tetracosane, which are commonly found in the vehicle of ophthalmic ointments. The GC-MS analysis of 1 ointment used postoperatively found matching peaks, suggesting deposition of those compounds on the IOL. PMID:16565014

  15. Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes.

    PubMed

    Zhang, Yichi; Liang, Xiao Ying; Liu, Shu; Lee, Jacky W Y; Bhaskar, Srinivasan; Lam, Dennis S C

    2016-01-01

    Purpose. To evaluate and compare the accuracy of different intraocular lens (IOL) power calculation formulas for eyes with an axial length (AL) greater than 26.00 mm. Methods. This study reviewed 407 eyes of 219 patients with AL longer than 26.0 mm. The refractive prediction errors of IOL power calculation formulas (SRK/T, Haigis, Holladay, Hoffer Q, and Barrett Universal II) using User Group for Laser Interference Biometry (ULIB) constants were evaluated and compared. Results. One hundred seventy-one eyes were enrolled. The Barrett Universal II formula had the lowest mean absolute error (MAE) and SRK/T and Haigis had similar MAE, and the statistical highest MAE were seen with the Holladay and Hoffer Q formulas. The interquartile range of the Barrett Universal II formula was also the lowest among all the formulas. The Barrett Universal II formulas yielded the highest percentage of eyes within ±1.0 D and ±0.5 D of the target refraction in this study (97.24% and 79.56%, resp.). Conclusions. Barrett Universal II formula produced the lowest predictive error and the least variable predictive error compared with the SRK/T, Haigis, Holladay, and Hoffer Q formulas. For high myopic eyes, the Barrett Universal II formula may be a more suitable choice. PMID:27119018

  16. Hydrophobic modification of polymethyl methacrylate as intraocular lenses material to improve the cytocompatibility.

    PubMed

    Wang, Bailiang; Lin, Quankui; Shen, Chenghui; Tang, Junmei; Han, Yuemei; Chen, Hao

    2014-10-01

    The development of posterior capsule opacification (PCO) after intraocular lenses (IOL) implantation for dealing with cataract is mainly due to the severe loss of the human lens epithelial cells (HLECs) during surgery contact. A novel poly (hedral oligomeric silsesquioxane-co-methyl methacrylate) copolymer (allyl POSS-PMMA) was synthesized by free radical polymerization method to promote the adhesion of HLECs. FT-IR and (1)H NMR measurements indicated the existence of POSS cage in the product, which demonstrated the successful synthesis of allyl POSS-PMMA copolymer. Effect of allyl POSS in the hybrids on crystal structure, surface wettability and morphology, optical transmission, thermodynamic properties and cytocompatibility was investigated in detail. X-ray diffraction peaks at 2θ∼11° and 12° indicated that POSS molecules had aggregated and crystallized. Thermogravimetric analysis-differential scanning calorimeter and optical transmission measurements confirmed that the allyl POSS-PMMA copolymer had high glass transition temperatures (more than 100°C) and good transparency. The hydrophilicity and morphology of PMMA and copolymers surfaces were characterized by static water contact angle and atomic force microscopy. The results revealed that the surface of the allyl POSS-PMMA copolymer displayed higher hydrophobicity and higher roughness than that of pure PMMA. The surface biocompatibility was evaluated by morphology and activity measurement with HLECs in vitro. The results verified that the surface of allyl POSS-PMMA copolymer films had more HLECs adhesion and better spreading morphology than that of PMMA film. PMID:24972346

  17. Impact of environmental temperature on optical power properties of intraocular lenses.

    PubMed

    Walker, Bennett N; James, Robert H; Calogero, Don; Ilev, Ilko K

    2014-01-20

    Optical power properties of lenses and materials in general can be influenced by thermal changes of the material and surrounding medium. In the case of an intraocular lens (IOL) implant, the spherical power (SP), cylinder power, (CP), astigmatism, and spherical aberration are the critical fundamental properties that can significantly impact its efficacy. Directly evaluating how changes in temperature can affect these optical properties may show the importance of considering temperature when evaluating IOL optical characteristics. In this paper, we present a quantitative study on evaluating the impact of environmental temperature changes on IOL fundamental optical properties by testing IOL samples with different materials (e.g., hydrophobic and hydrophilic) and designs (e.g., monofocal and toric) to better encompass types of IOLs in conventional use today. The results from this study demonstrate that significant changes are observed as temperatures are changed from room temperature (20°C) to slightly above body temperature (40°C). Findings indicate that evaluating optical properties at arbitrary temperatures could significantly affect the characterization of IOLs that are already near the tolerance thresholds. PMID:24514132

  18. [The influence of electro-stimulation anaesthesia on the intraocular pressure (author's transl)].

    PubMed

    Abdulla, W; Oggel, K; Schwab, R

    1981-04-01

    The effect of electrostimulation anaesthesia was studied in 23 patients undergoing ophthalmic surgery. Intraocular pressure (IOP) was measured 30 minutes after premedication (I), immediately after intubation (II), after the start of stimulation and relaxation (III) and after the establishment of full relaxation and achievement of full stimulation (IV). After intubation IOP increased from 16.4 +/- 3.3 mm Hg to 19.4 +/- 5.6 mm Hg (p less than 0.05), but decreased at reading IV statistically significantly compared with reading I to 12.7 +/- 2.8 mm Hg. To investigate the effect of electrostimulation alone on IOP, we performed tonometry on 10 control persons, in whom we observed a rise in IOP which can be attributed to current induced contractions of the extraocular muscles. The results demonstrate that there is a direct relation between electrostimulation and extraocular muscles, and we find it essential to relax the patients sufficiently to avoid hazards of IOP elevation. PMID:7247003

  19. Sutureless intrascleral intraocular lens fixation with lamellar dissection of scleral tunnel

    PubMed Central

    Kawaji, Takahiro; Sato, Tomoki; Tanihara, Hidenobu

    2016-01-01

    Purpose To report the results of sutureless scleral fixation of a posterior chamber intraocular lens (IOL) by using our developed simple technique. Methods We retrospectively reviewed the medical records of 48 eyes of 47 patients who underwent sutureless intrascleral IOL fixation by using our modified technique. A 25-gauge microvitreoretinal knife was used to perform sclerotomies and create limbus-parallel scleral tunnels with lamellar dissection in which the haptics were fixed. Results The IOLs were fixed and centered well. The mean follow-up period was 26.7 months. Postoperative complications included smooth vitreous hemorrhage in four eyes (8.3%), cystoid macular edema in two eyes (4.2%), and iris capture of the IOL in two eyes (4.2%). No other complications, such as breakage of the IOL, spontaneous IOL dislocation, or retinal detachment, were detected during the follow-up period. Conclusion The lamellar dissection of the limbus-parallel scleral tunnel can simplify the forceps-assisted introduction of the haptics into the scleral tunnel, and this technique seemed to be safe. PMID:26869757

  20. Visual and Refractive Outcomes of a Toric Presbyopia-Correcting Intraocular Lens

    PubMed Central

    Epitropoulos, Alice T.

    2016-01-01

    Purpose. To evaluate outcomes in astigmatic patients implanted with the Trulign (Bausch + Lomb) toric presbyopia-correcting intraocular lens (IOL) during cataract surgery in a clinical practice setting. Methods. Retrospective study in 40 eyes (31 patients) that underwent cataract extraction and IOL implantation in a procedure using intraoperative wavefront aberrometry guidance (ORA system). Endpoints included uncorrected visual acuity (VA), reduction in refractive cylinder, accuracy to target, axis orientation, and safety. Results. At postoperative month 1, refractive cylinder was ≤0.50 D in 97.5% of eyes (≤1.00 D in 100%), uncorrected distance VA was 20/25 or better in 95%, uncorrected intermediate VA was 20/25 or better in 95%, and uncorrected near VA was 20/40 (J3 equivalent) or better in 92.5%. Manifest refraction spherical equivalent was within 1.00 D of target in 95% of eyes and within 0.50 D in 82.5%. Lens rotation was <5° and best-corrected VA was 20/25 or better in all eyes. Conclusion. The IOL effectively reduced refractive cylinder and provided excellent uncorrected distance and intermediate vision and functional near vision. Refractive predictability and rotational stability were exceptional. Implantation of this toric presbyopia-correcting IOL using ORA intraoperative aberrometry provides excellent refractive and visual outcomes in a standard of care setting. PMID:26885382

  1. Ultrasound Biomicroscopy Comparison of Ab Interno and Ab Externo Intraocular Lens Scleral Fixation.

    PubMed

    Horiguchi, Lie; Garcia, Patricia Novita; Malavazzi, Gustavo Ricci; Allemann, Norma; Gomes, Rachel L R

    2016-01-01

    Purpose. To compare ab interno and ab externo scleral fixation of posterior chamber intraocular lenses (PCIOL) using ultrasound biomicroscopy (UBM). Methods. Randomized patients underwent ab externo or ab interno scleral fixation of a PCIOL. Ultrasound biomicroscopy was performed 3 to 6 months postoperatively, to determine PCIOL centration, IOL distance to the iris at 12, 3, 6, and 9 hours, and haptics placement in relation to the ciliary sulcus. Results. Fifteen patients were enrolled in the study. The ab externo technique was used in 7 eyes (46.6%) and the ab interno in 8 eyes (53.3%). In the ab externo technique, 14 haptics were located: 4 (28.57%) in the ciliary sulcus; 2 (14.28%) anterior to the sulcus; and 8 (57.14%) posterior to the sulcus, 6 in the ciliary body and 2 posterior to the ciliary body. In the ab interno group, 4 haptics (25.0%) were in the ciliary sulcus, 2 (12.50%) anterior to the sulcus, and 10 (75.0%) posterior to the sulcus, 4 in the ciliary body and 6 posterior to the ciliary body. Conclusions. Ab externo and ab interno scleral fixation techniques presented similar results in haptic placement. Ab externo technique presented higher vertical tilt when compared to the ab interno. PMID:27293878

  2. Intraocular pressure (IOP) in relation to four levels of daily geomagnetic and extreme yearly solar activity.

    PubMed

    Stoupel, E; Goldenfeld, M; Shimshoni, M; Siegel, R

    1993-02-01

    The link between geomagnetic field activity (GMA), solar activity and intraocular pressure (IOP) in healthy individuals was investigated. The IOP of 485 patients (970 eyes) was recorded over three nonconsecutive years (1979, 1986, 1989) which were characterized by maximal solar activity (1979, 1989) or minimal solar activity (1986). The measurements were also correlated with four categories of GMA activity: quiet (level I0), unsettled (II0), active (III0), and stormy (IV0). Participants were also differentiated by age and sex. We found that IOP was lowest on days of level IV0 (stromy) GMA. The drop in IOP concomitant with a decrease in GMA level was more significant during periods of low solar activity and in persons over 65 years of age. There was a trend towards higher IOP values on days of levels II0 and IV0 GMA in years of high solar activity. Differences between the sexes and among individuals younger than 65 years were not significant. Our results show an interesting aspect of environmental influence on the healthy population. PMID:8468099

  3. Twenty-four-Hour Measurement of Intraocular Pressure in Guinea Pigs (Cavia porcellus).

    PubMed

    Ansari-Mood, Maneli; Mehdi-Rajaei, Seyed; Sadjadi, Reza; Selk-Ghaffari, Masoud; Williams, David L

    2016-01-01

    The objective of this study was to measure intraocular pressure (IOP) in intact, healthy guinea pigs (15 male, 15 female) every 2 h for a 24-h period. First, IOP was measured by using rebound tonometry (RBT). After a 1-min rest period, 0.5% proparacaine ophthalmic solution, a topical anesthetic, was applied to both eyes; 4 min after anesthetic instillation, IOP was measured by using applanation tonometry (APT). The IOP was lower during the light period (0700 to 1900) than during the dark phase (2000 to 0600). The lowest IOP by both RBT and APT (3.68 and 13.37 mm Hg, respectively) occurred at 0700, whereas maximal IOP occurred at 2300 for RBT (8.12 mm Hg) but at 2100 for APT (20.62 mm Hg). No significant differences in IOP between the left and right eyes or between RBT and APT were noted. In addition, daily variations in the IOP of guinea pigs seem to be independent of sex and body weight. The results of this study may be beneficial in the diagnosis and observation of glaucoma in guinea pigs. PMID:26817986

  4. Evaluation of actual retinal images produced by misaligned aspheric intraocular lenses in a model eye

    PubMed Central

    Fujikado, Takashi; Saika, Makoto

    2014-01-01

    Purpose To examine the effect of misalignment (decentration and tilt) of intraocular lenses (IOLs) on retinal image quality using a water-immersed model eye with corneal spherical aberration adjusted to the values found in normal human eyes (spherical aberration 0.25 μm; pupil diameter 6 mm). Methods Three types of IOL holders were prepared. The first was without decentration or tilt, the second had a decentration of 0.5 mm, and the third had a tilt of 5.0°. One spherical IOL and three aspherical IOLs, each with a power of +20 D, were set in the holders and their optical properties (wave front aberration, defocused modulation transfer function, defocused point spread function, and Landolt ring simulations) were compared. Results Coma aberrations generated by misaligned IOLs were related to the spherical aberration corrective power of the IOLs. Landolt ring simulations show that the depth of focus increased as spherical aberration increased and that the retinal image quality was degraded by increases in coma aberration. Conclusion Coma aberration was generated by IOLs with a large degree of spherical aberration correction, leading to reduced retinal image quality when the IOL was misaligned. This suggests that, in a clinical setting, the quality of vision might be improved by reducing the degree of coma aberration using IOLs that retain, or minimally correct, spherical aberration. PMID:25506203

  5. TRPV4 regulates calcium homeostasis, cytoskeletal remodeling, conventional outflow and intraocular pressure in the mammalian eye.

    PubMed

    Ryskamp, Daniel A; Frye, Amber M; Phuong, Tam T T; Yarishkin, Oleg; Jo, Andrew O; Xu, Yong; Lakk, Monika; Iuso, Anthony; Redmon, Sarah N; Ambati, Balamurali; Hageman, Gregory; Prestwich, Glenn D; Torrejon, Karen Y; Križaj, David

    2016-01-01

    An intractable challenge in glaucoma treatment has been to identify druggable targets within the conventional aqueous humor outflow pathway, which is thought to be regulated/dysregulated by elusive mechanosensitive protein(s). Here, biochemical and functional analyses localized the putative mechanosensitive cation channel TRPV4 to the plasma membrane of primary and immortalized human TM (hTM) cells, and to human and mouse TM tissue. Selective TRPV4 agonists and substrate stretch evoked TRPV4-dependent cation/Ca(2+) influx, thickening of F-actin stress fibers and reinforcement of focal adhesion contacts. TRPV4 inhibition enhanced the outflow facility and lowered perfusate pressure in biomimetic TM scaffolds populated with primary hTM cells. Systemic delivery, intraocular injection or topical application of putative TRPV4 antagonist prodrug analogs lowered IOP in glaucomatous mouse eyes and protected retinal neurons from IOP-induced death. Together, these findings indicate that TRPV4 channels function as a critical component of mechanosensitive, Ca(2+)-signaling machinery within the TM, and that TRPV4-dependent cytoskeletal remodeling regulates TM stiffness and outflow. Thus, TRPV4 is a potential IOP sensor within the conventional outflow pathway and a novel target for treating ocular hypertension. PMID:27510430

  6. Distribution of salicylate in lens and intraocular fluids and its effect on cataract formation.

    PubMed

    Cotlier, E; Sharma, Y R; Niven, T; Brescia, M

    1983-06-14

    Retrospective studies on cataract development in patients with rheumatoid arthritis or osteoarthritis revealed a retardant effect of aspirin on diabetic and non-diabetic cataracts. The effect of aspirin is dose-dependent. The correlation coefficient between years delay for various cataracts subcategories versus aspirin taken (in tablets per day X years of intake) was 0.69. The ocular pharmacokinetics of 14C acetylsalicylic acid or salicylate were determined after intravenous or intraperitoneal administration to rabbits. 14C acetylsalicylic acid penetrates rapidly into rabbit lens and aqueous humor after intravenous administration. After intraperitoneal administration, salicylate levels in rabbit plasma, similar to those of humans receiving four to six aspirin tablets (325 mg each), result in accumulation of salicylate by lens (mean +/- SD) of 405 +/- 72 mumoles/g and 620 +/- 30 mumoles/g at two and four hours, respectively. At those dosages, salicylate is cleared in 24 hours from rabbit plasma and intraocular fluids, but retained by lens. Penetration of salicylate into rabbit lens and rat lens is dose-dependent. The retardant aspirin effect in diabetic cataracts is linked to inhibition of tissue aldose reductase and lens protein glycosylation. Deceleration of galactose cataract formation in rats occurs after daily salicylate intraperitoneal injections of 100 mg/kg a day. PMID:6859071

  7. Development of a human eye model incorporated with intraocular scattering for visual performance assessment

    NASA Astrophysics Data System (ADS)

    Chen, Yi-Chun; Jiang, Chong-Jhih; Yang, Tsung-Hsun; Sun, Ching-Cherng

    2012-07-01

    A biometry-based human eye model was developed by using the empirical anatomic and optical data of ocular parameters. The gradient refractive index of the crystalline lens was modeled by concentric conicoid isoindical surfaces and was adaptive to accommodation and age. The chromatic dispersion of ocular media was described by Cauchy equations. The intraocular scattering model was composed of volumetric Mie scattering in the cornea and the crystalline lens, and a diffusive-surface model at the retina fundus. The retina was regarded as a Lambertian surface and was assigned its corresponding reflectance at each wavelength. The optical performance of the eye model was evaluated in CodeV and ASAP and presented by the modulation transfer functions at single and multiple wavelengths. The chromatic optical powers obtained from this model resembled that of the average physiological eyes. The scattering property was assessed by means of glare veiling luminance and compared with the CIE general disability glare equation. By replacing the transparent lens with a cataractous lens, the disability glare curve of cataracts was generated to compare with the normal disability glare curve. This model has high potential for investigating visual performance in ordinary lighting and display conditions and under the influence of glare sources.

  8. Precise modelling of the eye for proton therapy of intra-ocular tumours

    NASA Astrophysics Data System (ADS)

    Dobler, Barbara; Bendl, Rolf

    2002-02-01

    A new method is described that allows precise modelling of organs at risk and target volume for radiation therapy of intra-ocular tumours. The aim is to optimize the dose distribution and thus to reduce normal tissue complication probability. A geometrical 3D model based on elliptic shapes was developed that can be used for multimodal model-based segmentation of 3D patient data. The tumour volume cannot be clearly identified in CT and MR data, whereas the tumour outline can be discriminated very precisely in fundus photographs. Therefore, a multimodal 2D fundus diagram was developed, which allows us to correlate and display simultaneously information extracted from the eye model, 3D data and the fundus photograph. Thus, the connection of fundus diagram and 3D data is well-defined and the 3D volume can be calculated directly from the tumour outline drawn onto the fundus photograph and the tumour height measured by ultrasound. The method allows the calculation of a precise 3D eye model of the patient, including the different structures of the eye as well as the tumour volume. The method was developed as part of the new 3D treatment planning system OCTOPUS for proton therapy of ocular tumours within a national research project together with the Hahn-Meitner-Institut Berlin.

  9. Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes

    PubMed Central

    Zhang, Yichi; Liang, Xiao Ying; Liu, Shu; Lee, Jacky W. Y.; Bhaskar, Srinivasan; Lam, Dennis S. C.

    2016-01-01

    Purpose. To evaluate and compare the accuracy of different intraocular lens (IOL) power calculation formulas for eyes with an axial length (AL) greater than 26.00 mm. Methods. This study reviewed 407 eyes of 219 patients with AL longer than 26.0 mm. The refractive prediction errors of IOL power calculation formulas (SRK/T, Haigis, Holladay, Hoffer Q, and Barrett Universal II) using User Group for Laser Interference Biometry (ULIB) constants were evaluated and compared. Results. One hundred seventy-one eyes were enrolled. The Barrett Universal II formula had the lowest mean absolute error (MAE) and SRK/T and Haigis had similar MAE, and the statistical highest MAE were seen with the Holladay and Hoffer Q formulas. The interquartile range of the Barrett Universal II formula was also the lowest among all the formulas. The Barrett Universal II formulas yielded the highest percentage of eyes within ±1.0 D and ±0.5 D of the target refraction in this study (97.24% and 79.56%, resp.). Conclusions. Barrett Universal II formula produced the lowest predictive error and the least variable predictive error compared with the SRK/T, Haigis, Holladay, and Hoffer Q formulas. For high myopic eyes, the Barrett Universal II formula may be a more suitable choice. PMID:27119018

  10. Lowered intraocular pressure in a glaucoma patient after intravitreal injection of ocriplasmin

    PubMed Central

    McClintock, Michael; MacCumber, Mathew W

    2015-01-01

    We report the case of a glaucoma patient who received a single intravitreal injection of 125 µg ocriplasmin for vitreomacular traction in the right eye. The patient had bilateral advanced glaucoma and had previously undergone an implantation of an Ahmed glaucoma valve in the right eye and trabeculectomy in both eyes. The patient was using three topical ophthalmic intraocular pressure (IOP)-lowering medications on the day of injection. Baseline uncorrected Snellen visual acuity was 20/80-1 and IOP was 19 mmHg. Resolution of vitreomacular traction was achieved 1 week after injection. IOP was transiently decreased, reaching a maximum reduction of 12 mmHg below baseline at 1 month after injection, when serous choroidal effusion was also present. IOP returned to baseline levels and choroidal effusion resolved at 2 months after injection of IOP-lowering medication. Vitrectomy with epiretinal membrane and internal limiting membrane peeling, endolaser photocoagulation, and fluid–gas exchange were performed in the right eye ~3.5 months after injection to treat persistent epiretinal membrane, and presumed tractional retinal detachment. Final visual acuity was 20/50+ and IOP was 18 mmHg at 16 weeks after surgery. To our knowledge, this is the first report of IOP reduction and serous choroidal effusion after ocriplasmin injection. PMID:26604668

  11. Perioperative dorzolamide-timolol intervention for rising intraocular pressure during steep Trendelenburg positioned surgery.

    PubMed

    Molloy, Bonnie; Cong, Xiaomei

    2014-06-01

    Elevated intraocular pressure (IOP) and venous congestion may produce a low ocular perfusion state that can lead to postoperative visual loss (POVL). The literature cites the importance of early IOP reduction to prevent optic nerve damage and visual loss. This study examined dorzolamide hydrochloride and timolol maleate (Cosopt) eyedrops on reducing elevated IOP during laparoscopic surgery with the patient in steep Trendelenburg position. A quasi-experimental study design was used. Subjects involving robotic urologic and gynecologic procedures at 3 separate medical centers were included. The medication was administered topically to both eyes at time points when IOP approached 40 mm Hg. The IOP was measured at 30-minute intervals compared with a supine, anesthetized baseline and final postprocedure supine measurements. A total of 194 patients were recruited, and 63 patients received dorzolamide-timolol treatment when IOP levels reached 38 to 40 mm Hg. Repeated-measures analysis of variance showed that IOP values dropped significantly after drug intervention at 60, 90, and 120 minutes (P < .001). Effect sizes of pharmacologic intervention on IOP reduction were strong (partial eta2 of 0.60 to 0.66). Treatment with dorzolamide-timolol eyedrops significantly reduces elevated IOP of patients who undergo lengthy laparoscopic surgery in the steep Trendelenburg position. PMID:25109158

  12. Tram-Track Suture Technique for Pupillary Capture of a Scleral Fixated Intraocular Lens

    PubMed Central

    Kim, Sung In; Kim, Kiseok

    2016-01-01

    Purpose To report a new technique using tram-track suture for pupillary capture of a scleral fixated posterior chamber intraocular lens (PC-IOL) to reposition the tilted IOL. Methods In this prospective interventional case series, we describe a tram-track suture for pupillary capture of a scleral fixated PC-IOL. A long straight needle with double-armed 10-0 polypropylene is passed behind the iris and just above the optic portion (tilted forward) of the IOL. The other straight needle with double-armed 10-0 polypropylene is passed just below the optic portion (tilted backward) of the IOL. After the IOL is repositioned properly, the polypropylene sutures are gently pulled and tied. Results Four eyes of 4 patients underwent tram-track suture for pupillary capture of a scleral fixated PC-IOL. No intra- or postoperative complications were noted, and no pupillary captures were detected during the follow-up period. Conclusions The tram-track suture technique provides good centration and stability of a PC-IOL. This technique is an easy and effective way to reposition pupillary capture of an IOL. Further, it is also minimally invasive as it maintains a closed system. PMID:27462257

  13. A safe method of ciliary sulcus fixation of foldable intraocular lens using a ciliary sulcus guide.

    PubMed

    Can, Ertuğrul; Gül, Adem; Birinci, Hakkı

    2016-08-01

    To describe a novel technique for implantation of intraocular lens in the absence of capsular support using a ciliary sulcus guide. Based on the anatomic knowledge of the ciliary sulcus and the sclera, a new instrument was developed to pierce the needle safely through the ciliary sulcus and sclera. While the foldable lens is stored inside the cartridge, the leading haptic is sutured with a cow-hitch knot. The needle is then inserted into the ciliary sulcus guide. The tip of the guide is inserted from the corneal incision and proceeded under the iris to touch and fit the ciliary sulcus. The needle is pushed from back side. The needle comes out at precise point at the sclera. Implantation of the lens was performed through a 2.8 mm clear cornea incision using the injector. The trailing haptic is tied after implantation, and then the same procedure is performed at the opposite side. We performed this technique to 15 aphakic eyes without sufficient capsular support. There was no bleeding or other intraoperative complication. All the points coming out the sclera were between 2 and 2.5 mm from the limbus. The ab interno technique for scleral fixation of IOL is quicker, easier and less traumatic then ab externo techniques. A new ciliary sulcus guide which is usable with both straight and curved needles eliminates the blind maneuvers of ab interno technique and makes this technique more safe and precise. PMID:26439372

  14. Safety and efficacy of travoprost solution for the treatment of elevated intraocular pressure

    PubMed Central

    Quaranta, Luciano; Riva, Ivano; Katsanos, Andreas; Floriani, Irene; Centofanti, Marco; Konstas, Anastasios G P

    2015-01-01

    Travoprost is a prostaglandin analogue widely used for reducing intraocular pressure (IOP) in patients affected with glaucoma and ocular hypertension. It exerts its ocular hypotensive effect through the prostaglandin FP receptors, located in the ciliary muscle and the trabecular meshwork. Several studies have shown that topical administration of travoprost induces a mean IOP reduction ranging from 25% to 32%, and sustained throughout the 24-hour cycle. When compared with timolol, travoprost is more effective at reducing IOP, while generally no difference has been found in the head-to-head comparison with other prostaglandin analogues. The fixed combination of travoprost and timolol has demonstrated a hypotensive efficacy comparable to the concomitant administration of the two drugs. Recently, a new preservative-free formulation of travoprost 0.004% has been marketed for reducing tolerability-related problems in subjects affected with ocular surface disease. Low rates of topical and systemic adverse reactions, strong ocular hypotensive efficacy, and once-a-day dosing make travoprost a first-line treatment for patients affected with elevated IOP. PMID:25914522

  15. Sustained intraocular pressure reduction throughout the day with travoprost ophthalmic solution 0.004%

    PubMed Central

    Dubiner, Harvey B; Noecker, Robert

    2012-01-01

    Background The purpose of this study was to characterize intraocular pressure (IOP) reduction throughout the day with travoprost ophthalmic solution 0.004% dosed once daily in the evening. Methods The results of seven published, randomized clinical trials including at least one arm in which travoprost 0.004% was dosed once daily in the evening were integrated. Means (and standard deviations) of mean baseline and on-treatment IOP, as well as mean IOP reduction and mean percent IOP reduction at 0800, 1000, and 1600 hours at weeks 2 and 12 were calculated. Results From a mean baseline IOP ranging from 25.0 to 27.2 mmHg, mean IOP on treatment ranged from 17.4 to 18.8 mmHg across all visits and time points. Mean IOP reductions from baseline ranged from 7.6 to 8.4 mmHg across visits and time points, representing a mean IOP reduction of 30%. Results of the safety analysis were consistent with the results from the individual studies for travoprost ophthalmic solution 0.004%, with ocular hyperemia being the most common side effect. Conclusion Travoprost 0.004% dosed once daily in the evening provides sustained IOP reduction throughout the 24-hour dosing interval in subjects with ocular hypertension or open-angle glaucoma. No reduction of IOP-lowering efficacy was observed at the 1600-hour time point which approached the end of the dosing interval. PMID:22536047

  16. Twenty-four–Hour Measurement of Intraocular Pressure in Guinea Pigs (Cavia porcellus)

    PubMed Central

    Ansari-Mood, Maneli; Mehdi-Rajaei, Seyed; Sadjadi, Reza; Selk-Ghaffari, Masoud; Williams, David L

    2016-01-01

    The objective of this study was to measure intraocular pressure (IOP) in intact, healthy guinea pigs (15 male, 15 female) every 2 h for a 24-h period. First, IOP was measured by using rebound tonometry (RBT). After a 1-min rest period, 0.5% proparacaine ophthalmic solution, a topical anesthetic, was applied to both eyes; 4 min after anesthetic instillation, IOP was measured by using applanation tonometry (APT). The IOP was lower during the light period (0700 to 1900) than during the dark phase (2000 to 0600). The lowest IOP by both RBT and APT (3.68 and 13.37 mm Hg, respectively) occurred at 0700, whereas maximal IOP occurred at 2300 for RBT (8.12 mm Hg) but at 2100 for APT (20.62 mm Hg). No significant differences in IOP between the left and right eyes or between RBT and APT were noted. In addition, daily variations in the IOP of guinea pigs seem to be independent of sex and body weight. The results of this study may be beneficial in the diagnosis and observation of glaucoma in guinea pigs. PMID:26817986

  17. Correlation between short-term and long-term intraocular pressure fluctuation in glaucoma patients

    PubMed Central

    Tojo, Naoki; Abe, Shinya; Miyakoshi, Mari; Hayashi, Atsushi

    2016-01-01

    Purpose We investigated correlations between short-term and long-term intraocular pressure (IOP) fluctuations. Methods We examined 50 eyes of glaucoma patients who were followed for >2 years. We measured short-term IOP fluctuation using a Triggerfish® contact lens sensor (CLS). The short-term IOP fluctuation (mVeq) was defined as the difference between the maximum value and the minimum value measured during the 24-hour course with CLS. The long-term IOP fluctuation was defined by four parameters: 1) the mean IOP (mmHg) determined during follow-up; 2) the IOP difference, which was defined as the difference between the maximum IOP and the minimum IOP; 3) the standard deviation of IOP; and 4) the peak IOP, which was defined as the maximum IOP. Correlations between these parameters and the short-term IOP fluctuation were examined. Results The mean follow-up period was 5.4 years. The average IOP was 15.0±4.0 mmHg. The range of short-term IOP fluctuation identified with CLS was significantly correlated with all the four long-term IOP fluctuation parameters. Conclusion Short-term IOP fluctuations were found to be associated with long-term IOP fluctuations. Examination of 24-hour IOP fluctuations with the CLS might be useful for predicting the long-term IOP fluctuation.

  18. Ultrasound Biomicroscopy Comparison of Ab Interno and Ab Externo Intraocular Lens Scleral Fixation

    PubMed Central

    Horiguchi, Lie; Garcia, Patricia Novita; Malavazzi, Gustavo Ricci; Allemann, Norma

    2016-01-01

    Purpose. To compare ab interno and ab externo scleral fixation of posterior chamber intraocular lenses (PCIOL) using ultrasound biomicroscopy (UBM). Methods. Randomized patients underwent ab externo or ab interno scleral fixation of a PCIOL. Ultrasound biomicroscopy was performed 3 to 6 months postoperatively, to determine PCIOL centration, IOL distance to the iris at 12, 3, 6, and 9 hours, and haptics placement in relation to the ciliary sulcus. Results. Fifteen patients were enrolled in the study. The ab externo technique was used in 7 eyes (46.6%) and the ab interno in 8 eyes (53.3%). In the ab externo technique, 14 haptics were located: 4 (28.57%) in the ciliary sulcus; 2 (14.28%) anterior to the sulcus; and 8 (57.14%) posterior to the sulcus, 6 in the ciliary body and 2 posterior to the ciliary body. In the ab interno group, 4 haptics (25.0%) were in the ciliary sulcus, 2 (12.50%) anterior to the sulcus, and 10 (75.0%) posterior to the sulcus, 4 in the ciliary body and 6 posterior to the ciliary body. Conclusions. Ab externo and ab interno scleral fixation techniques presented similar results in haptic placement. Ab externo technique presented higher vertical tilt when compared to the ab interno. PMID:27293878

  19. Revealing anisotropic properties of cornea at different intraocular pressures using optical coherence elastography

    NASA Astrophysics Data System (ADS)

    Li, Jiasong; Singh, Manmohan; Han, Zhaolong; Wu, Chen; Nair, Achuth; Aglyamov, Salavat R.; Twa, Michael D.; Larin, Kirill V.

    2016-03-01

    In this study we have evaluated the elastic anisotropy of porcine corneas with increasing intraocular pressures (IOPs) using a noncontact optical coherence elastography (OCE) technique. A focused air-pulse induced low amplitude (<=10 μm) elastic waves in fresh porcine corneas (n=9) in situ in the whole eye-globe configuration. A phase-stabilized swept source optical coherence elastography (PhS-SSOCE) system imaged the propagation of the elastic wave in different stepped radial directions. A closed-loop feedback system was utilized to artificially manipulate the IOP, and OCE measurements were repeated while the IOP was increased in 5 mmHg increments from 15 to 30 mmHg. The OCE measurements demonstrated that the elastic anisotropy of the cornea became more pronounced at higher IOPs, and that there were distinct radial angles of higher and lower stiffness. The presented noncontact OCE method was capable of detecting and assessing the corneal elastic anisotropy as a function of IOP. Due to the noninvasive nature and small amplitude of the elastic wave, this method may be able to provide additional information about corneal health and integrity in vivo.

  20. Sustained intraocular VEGF neutralization results in retinal neurodegeneration in the Ins2Akita diabetic mouse

    PubMed Central

    Hombrebueno, Jose R.; Ali, Imran HA.; Xu, Heping; Chen, Mei

    2015-01-01

    Current therapies that target vascular endothelial growth factor (VEGF) have become a mainstream therapy for the management of diabetic macular oedema. The treatment involves monthly repeated intravitreal injections of VEGF inhibitors. VEGF is an important growth factor for many retinal cells, including different types of neurons. In this study, we investigated the adverse effect of multiple intravitreal anti-VEGF injections (200 ng/μl/eye anti-mouse VEGF164, once every 2 weeks totalling 5–6 injections) to retinal neurons in Ins2Akita diabetic mice. Funduscopic examination revealed the development of cotton wool spot-like lesions in anti-VEGF treated Ins2Akita mice after 5 injections. Histological investigation showed focal swellings of retinal nerve fibres with neurofilament disruption. Furthermore, anti-VEGF-treated Ins2Akita mice exhibited impaired electroretinographic responses, characterized by reduced scotopic a- and b-wave and oscillatory potentials. Immunofluorescent staining revealed impairment of photoreceptors, disruptions of synaptic structures and loss of amacrine and retinal ganglion cells in anti-VEGF treated Ins2Akita mice. Anti-VEGF-treated WT mice also presented mild amacrine and ganglion cell death, but no overt abnormalities in photoreceptors and synaptic structures. At the vascular level, exacerbated albumin leakage was observed in anti-VEGF injected diabetic mice. Our results suggest that sustained intraocular VEGF neutralization induces retinal neurodegeneration and vascular damage in the diabetic eye. PMID:26671074