Sample records for activation energies measured

  1. Assessment of Physical Activity and Energy Expenditure: An Overview of Objective Measures

    PubMed Central

    Hills, Andrew P.; Mokhtar, Najat; Byrne, Nuala M.

    2014-01-01

    The ability to assess energy expenditure (EE) and estimate physical activity (PA) in free-living individuals is extremely important in the global context of non-communicable diseases including malnutrition, overnutrition (obesity), and diabetes. It is also important to appreciate that PA and EE are different constructs with PA defined as any bodily movement that results in EE and accordingly, energy is expended as a result of PA. However, total energy expenditure, best assessed using the criterion doubly labeled water (DLW) technique, includes components in addition to physical activity energy expenditure, namely resting energy expenditure and the thermic effect of food. Given the large number of assessment techniques currently used to estimate PA in humans, it is imperative to understand the relative merits of each. The goal of this review is to provide information on the utility and limitations of a range of objective measures of PA and their relationship with EE. The measures discussed include those based on EE or oxygen uptake including DLW, activity energy expenditure, physical activity level, and metabolic equivalent; those based on heart rate monitoring and motion sensors; and because of their widespread use, selected subjective measures. PMID:25988109

  2. Simultaneous determination of interfacial energy and growth activation energy from induction time measurements

    NASA Astrophysics Data System (ADS)

    Shiau, Lie-Ding; Wang, Hsu-Pei

    2016-05-01

    A model is developed in this work to calculate the interfacial energy and growth activation energy of a crystallized substance from induction time data without the knowledge of the actual growth rate. Induction time data for αL-glutamic acid measured with a turbidity probe for various supersaturations at temperatures from 293 to 313 K are employed to verify the developed model. In the model a simple empirical growth rate with growth order 2 is assumed because experiments are conducted at low supersaturation. The results indicate for αL-glutamic acid that the growth activation energy is 39 kJ/mol, which suggests that the growth rate of small nuclei in the agitated induction time experiments is integration controlled. The interfacial energy obtained from the current model is in the range of 5.2-7.4 mJ/m2, which is slightly greater than that obtained from the traditional method (ti-1∝J) for which the value is in the range 4.1-5.7 mJ/m2.

  3. Activation energy measurements of cheese

    USDA-ARS?s Scientific Manuscript database

    Temperature sweeps of cheeses using small amplitude oscillatory shear tests produced values for activation energy of flow (Ea) between 30 and 44 deg C. Soft goat cheese and Queso Fresco, which are high-moisture cheeses and do not flow when heated, exhibited Ea values between 30 and 60 kJ/mol. The ...

  4. The use of a running wheel to measure activity in rodents: relationship to energy balance, general activity, and reward.

    PubMed

    Novak, Colleen M; Burghardt, Paul R; Levine, James A

    2012-03-01

    Running wheels are commonly employed to measure rodent physical activity in a variety of contexts, including studies of energy balance and obesity. There is no consensus on the nature of wheel-running activity or its underlying causes, however. Here, we will begin by systematically reviewing how running wheel availability affects physical activity and other aspects of energy balance in laboratory rodents. While wheel running and physical activity in the absence of a wheel commonly correlate in a general sense, in many specific aspects the two do not correspond. In fact, the presence of running wheels alters several aspects of energy balance, including body weight and composition, food intake, and energy expenditure of activity. We contend that wheel-running activity should be considered a behavior in and of itself, reflecting several underlying behavioral processes in addition to a rodent's general, spontaneous activity. These behavioral processes include defensive behavior, predatory aggression, and depression- and anxiety-like behaviors. As it relates to energy balance, wheel running engages several brain systems-including those related to the stress response, mood, and reward, and those responsive to growth factors-that influence energy balance indirectly. We contend that wheel-running behavior represents factors in addition to rodents' tendency to be physically active, engaging additional neural and physiological mechanisms which can then independently alter energy balance and behavior. Given the impact of wheel-running behavior on numerous overlapping systems that influence behavior and physiology, this review outlines the need for careful design and interpretation of studies that utilize running wheels as a means for exercise or as a measurement of general physical activity. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. The use of a running wheel to measure activity in rodents: Relationship to energy balance, general activity, and reward

    PubMed Central

    Levine, James A.

    2015-01-01

    Running wheels are commonly employed to measure rodent physical activity in a variety of contexts, including studies of energy balance and obesity. There is no consensus on the nature of wheel-running activity or its underlying causes, however. Here, we will begin by systematically reviewing how running wheel availability affects physical activity and other aspects of energy balance in laboratory rodents. While wheel running and physical activity in the absence of a wheel commonly correlate in a general sense, in many specific aspects the two do not correspond. In fact, the presence of running wheels alters several aspects of energy balance, including body weight and composition, food intake, and energy expenditure of activity. We contend that wheel-running activity should be considered a behavior in and of itself, reflecting several underlying behavioral processes in addition to a rodent's general, spontaneous activity. These behavioral processes include defensive behavior, predatory aggression, and depression- and anxiety-like behaviors. As it relates to energy balance, wheel running engages several brain systems—including those related to the stress response, mood, and reward, and those responsive to growth factors—that influence energy balance indirectly. We contend that wheel-running behavior represents factors in addition to rodents' tendency to be physically active, engaging additional neural and physiological mechanisms which can then independently alter energy balance and behavior. Given the impact of wheel-running behavior on numerous overlapping systems that influence behavior and physiology, this review outlines the need for careful design and interpretation of studies that utilize running wheels as a means for exercise or as a measurement of general physical activity. PMID:22230703

  6. Accuracy of a novel multi-sensor board for measuring physical activity and energy expenditure

    PubMed Central

    Lester, Jonathan; Migotsky, Sean; Goh, Jorming; Higgins, Lisa; Borriello, Gaetano

    2011-01-01

    The ability to relate physical activity to health depends on accurate measurement. Yet, none of the available methods are fully satisfactory due to several factors. This study examined the accuracy of a multi-sensor board (MSB) that infers activity types (sitting, standing, walking, stair climbing, and running) and estimates energy expenditure in 57 adults (32 females) 39.2 ± 13.5 years. In the laboratory, subjects walked and ran on a treadmill over a select range of speeds and grades for 3 min each (six stages in random order) while connected to a stationary calorimeter, preceded and followed by brief sitting and standing. On a different day, subjects completed scripted activities in the field connected to a portable calorimeter. The MSB was attached to a strap at the right hip. Subjects repeated one condition (randomly selected) on the third day. Accuracy of inferred activities compared with recorded activities (correctly identified activities/total activities × 100) was 97 and 84% in the laboratory and field, respectively. Absolute accuracy of energy expenditure [100 – absolute value (kilocalories MSB – kilocalories calorimeter/kilocalories calorimeter) × 100] was 89 and 76% in the laboratory and field, the later being different (P < 0.05) from the calorimeter. Test–retest reliability for energy expenditure was significant in both settings (P < 0.0001; r = 0.97). In general, the MSB provides accurate measures of activity type in laboratory and field settings and energy expenditure during treadmill walking and running although the device underestimates energy expenditure in the field. PMID:21249383

  7. Measurement of Physical Activity and Energy Expenditure in Wheelchair Users: Methods, Considerations and Future Directions.

    PubMed

    Nightingale, Tom E; Rouse, Peter C; Thompson, Dylan; Bilzon, James L J

    2017-12-01

    Accurately measuring physical activity and energy expenditure in persons with chronic physical disabilities who use wheelchairs is a considerable and ongoing challenge. Quantifying various free-living lifestyle behaviours in this group is at present restricted by our understanding of appropriate measurement tools and analytical techniques. This review provides a detailed evaluation of the currently available measurement tools used to predict physical activity and energy expenditure in persons who use wheelchairs. It also outlines numerous considerations specific to this population and suggests suitable future directions for the field. Of the existing three self-report methods utilised in this population, the 3-day Physical Activity Recall Assessment for People with Spinal Cord Injury (PARA-SCI) telephone interview demonstrates the best reliability and validity. However, the complexity of interview administration and potential for recall bias are notable limitations. Objective measurement tools, which overcome such considerations, have been validated using controlled laboratory protocols. These have consistently demonstrated the arm or wrist as the most suitable anatomical location to wear accelerometers. Yet, more complex data analysis methodologies may be necessary to further improve energy expenditure prediction for more intricate movements or behaviours. Multi-sensor devices that incorporate physiological signals and acceleration have recently been adapted for persons who use wheelchairs. Population specific algorithms offer considerable improvements in energy expenditure prediction accuracy. This review highlights the progress in the field and aims to encourage the wider scientific community to develop innovative solutions to accurately quantify physical activity in this population.

  8. Measuring temperature-dependent activation energy in thermally activated processes: a 2D Arrhenius plot method.

    PubMed

    Li, Jian V; Johnston, Steven W; Yan, Yanfa; Levi, Dean H

    2010-03-01

    Thermally activated processes are characterized by two key quantities, activation energy (E(a)) and pre-exponential factor (nu(0)), which may be temperature dependent. The accurate measurement of E(a), nu(0), and their temperature dependence is critical for understanding the thermal activation mechanisms of non-Arrhenius processes. However, the classic 1D Arrhenius plot-based methods cannot unambiguously measure E(a), nu(0), and their temperature dependence due to the mathematical impossibility of resolving two unknown 1D arrays from one 1D experimental data array. Here, we propose a 2D Arrhenius plot method to solve this fundamental problem. Our approach measures E(a) at any temperature from matching the first and second moments of the data calculated with respect to temperature and rate in the 2D temperature-rate plane, and therefore is able to unambiguously solve E(a), nu(0), and their temperature dependence. The case study of deep level emission in a Cu(In,Ga)Se(2) solar cell using the 2D Arrhenius plot method reveals clear temperature dependent behavior of E(a) and nu(0), which has not been observable by its 1D predecessors.

  9. Unobtrusive measurement of indoor energy expenditure using an infrared sensor-based activity monitoring system.

    PubMed

    Hwang, Bosun; Han, Jonghee; Choi, Jong Min; Park, Kwang Suk

    2008-11-01

    The purpose of this study was to develop an unobtrusive energy expenditure (EE) measurement system using an infrared (IR) sensor-based activity monitoring system to measure indoor activities and to estimate individual quantitative EE. IR-sensor activation counts were measured with a Bluetooth-based monitoring system and the standard EE was calculated using an established regression equation. Ten male subjects participated in the experiment and three different EE measurement systems (gas analyzer, accelerometer, IR sensor) were used simultaneously in order to determine the regression equation and evaluate the performance. As a standard measurement, oxygen consumption was simultaneously measured by a portable metabolic system (Metamax 3X, Cortex, Germany). A single room experiment was performed to develop a regression model of the standard EE measurement from the proposed IR sensor-based measurement system. In addition, correlation and regression analyses were done to compare the performance of the IR system with that of the Actigraph system. We determined that our proposed IR-based EE measurement system shows a similar correlation to the Actigraph system with the standard measurement system.

  10. Correlating hydrogen oxidation and evolution activity on platinum at different pH with measured hydrogen binding energy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheng, WC; Zhuang, ZB; Gao, MR

    2015-01-08

    The hydrogen oxidation/evolution reactions are two of the most fundamental reactions in distributed renewable electrochemical energy conversion and storage systems. The identification of the reaction descriptor is therefore of critical importance for the rational catalyst design and development. Here we report the correlation between hydrogen oxidation/evolution activity and experimentally measured hydrogen binding energy for polycrystalline platinum examined in several buffer solutions in a wide range of electrolyte pH from 0 to 13. The hydrogen oxidation/evolution activity obtained using the rotating disk electrode method is found to decrease with the pH, while the hydrogen binding energy, obtained from cyclic voltammograms, linearlymore » increases with the pH. Correlating the hydrogen oxidation/evolution activity to the hydrogen binding energy renders a monotonic decreasing hydrogen oxidation/evolution activity with the hydrogen binding energy, strongly supporting the hypothesis that hydrogen binding energy is the sole reaction descriptor for the hydrogen oxidation/evolution activity on monometallic platinum.« less

  11. Technology Learning Activities. Design Brief--Measuring Inaccessible Distances. Alternative Energy Sources: Designing a Wind Powered Generator. Alternative Energy Sources: Designing a Hot Dog Heater Using Solar Energy.

    ERIC Educational Resources Information Center

    Technology Teacher, 1991

    1991-01-01

    These three learning activities are on measuring accessible distances, designing a wind powered generator, and designing a hot dog heater using solar energy. Each activity includes description of context, objectives, list of materials and equipment, challenge to students, and evaluation questions. (SK)

  12. Activation energy measurements in rheological analysis of cheese

    USDA-ARS?s Scientific Manuscript database

    Activation energy of flow (Ea) was calculated from temperature sweeps of cheeses with contrasting characteristics to determine its usefulness in predicting rheological behavior upon heating. Cheddar, Colby, whole milk Mozzarella, low moisture part skim Mozzarella, Parmesan, soft goat, and Queso Fre...

  13. The Limit of Free Magnetic Energy in Active Regions

    NASA Technical Reports Server (NTRS)

    Moore, Ron; Falconer, David; Sterling, Alphonse

    2012-01-01

    By measuring from active-region magnetograms a proxy of the free energy in the active region fs magnetic field, it has been found previously that (1) there is an abrupt upper limit to the free energy the field can hold that increases with the amount of magnetic field in the active region, the active region fs magnetic flux content, and (2) the free energy is usually near its limit when the field explodes in a CME/flare eruption. That is, explosive active regions are concentrated in a main-sequence path bordering the free-energy ]limit line in (flux content, free-energy proxy) phase space. Here, from measurement of Marshall Space Flight Center vector magnetograms, we find the magnetic condition that underlies the free ]energy limit and the accompanying main sequence of explosive active regions. Using a suitable free ]energy proxy measured from vector magnetograms of 44 active regions, we find that (1) in active regions at and near their free ]energy limit, the ratio of magnetic-shear free energy to the non ]free magnetic energy the potential field would have is approximately 1 in the core field, the field rooted along the neutral line, and (2) this ratio is progressively less in active regions progressively farther below their free ]energy limit. This shows that most active regions in which this core-field energy ratio is much less than 1 cannot be triggered to explode; as this ratio approaches 1, most active regions become capable of exploding; and when this ratio is 1 or greater, most active regions are compelled to explode. From these results we surmise the magnetic condition that determines the free ]energy limit is the ratio of the free magnetic energy to the non-free energy the active region fs field would have were it completely relaxed to its potential ]field configuration, and that this ratio is approximately 1 at the free-energy limit and in the main sequence of explosive active regions.

  14. Assessing physical activity using wearable monitors: measures of physical activity.

    PubMed

    Butte, Nancy F; Ekelund, Ulf; Westerterp, Klaas R

    2012-01-01

    Physical activity may be defined broadly as "all bodily actions produced by the contraction of skeletal muscle that increase energy expenditure above basal level." Physical activity is a complex construct that can be classified into major categories qualitatively, quantitatively, or contextually. The quantitative assessment of physical activity using wearable monitors is grounded in the measurement of energy expenditure. Six main categories of wearable monitors are currently available to investigators: pedometers, load transducers/foot-contact monitors, accelerometers, HR monitors, combined accelerometer and HR monitors, and multiple sensor systems. Currently available monitors are capable of measuring total physical activity as well as components of physical activity that play important roles in human health. The selection of wearable monitors for measuring physical activity will depend on the physical activity component of interest, study objectives, characteristics of the target population, and study feasibility in terms of cost and logistics. Future development of sensors and analytical techniques for assessing physical activity should focus on the dynamic ranges of sensors, comparability for sensor output across manufacturers, and the application of advanced modeling techniques to predict energy expenditure and classify physical activities. New approaches for qualitatively classifying physical activity should be validated using direct observation or recording. New sensors and methods for quantitatively assessing physical activity should be validated in laboratory and free-living populations using criterion methods of calorimetry or doubly labeled water.

  15. Activity promoting games and increased energy expenditure

    PubMed Central

    Lanningham-Foster, Lorraine; Foster, Randal C.; McCrady, Shelly K.; Jensen, Teresa B.; Mitre, Naim; Levine, James A.

    2009-01-01

    Objectives Children and adults spend large portions of their days in front of screens. Our hypothesis was that both children and adults would expend more calories and move more while playing activity-promoting video games compared to sedentary video games. Study Design In this single-group study, twenty-two healthy children (12 ± 2 years, 11 M, 11 F) and 20 adults (34 ± 11 years, 10 M, 10 F) were recruited. Energy expenditure and physical activity were measured while participants were resting, standing, watching television seated, sitting and playing a traditional sedentary video game, and while playing an activity-promoting video game (Nintendo® Wii™ Boxing). Physical activity was measured using accelerometers and energy expenditure was measured using an indirect calorimeter. Results Energy expenditure increased significantly above all activities when children or adults played Nintendo® Wii™ (mean increase over resting, 189 ± 63 kcal/hr, p < 0.001, and 148 ± 71 kcal/hr, p < 0.001, respectively). Upon examination of movement using accelerometry, children moved significantly more than adults (55 ± 5 AAU and 23 ± 2 AAU, respectively, p < 0.001) while playing Nintendo® Wii™. Conclusions Activity-promoting video games have the potential to increase movement and energy expenditure in children and adults. PMID:19324368

  16. Measurements of Generated Energy/Electrical Quantities from Locomotion Activities Using Piezoelectric Wearable Sensors for Body Motion Energy Harvesting

    PubMed Central

    Proto, Antonino; Penhaker, Marek; Bibbo, Daniele; Vala, David; Conforto, Silvia; Schmid, Maurizio

    2016-01-01

    In this paper, two different piezoelectric transducers—a ceramic piezoelectric, lead zirconate titanate (PZT), and a polymeric piezoelectric, polyvinylidene fluoride (PVDF)—were compared in terms of energy that could be harvested during locomotion activities. The transducers were placed into a tight suit in proximity of the main body joints. Initial testing was performed by placing the transducers on the neck, shoulder, elbow, wrist, hip, knee and ankle; then, five locomotion activities—walking, walking up and down stairs, jogging and running—were chosen for the tests. The values of the power output measured during the five activities were in the range 6 µW–74 µW using both transducers for each joint. PMID:27077867

  17. Energy expenditure and activity among Hadza hunter-gatherers.

    PubMed

    Pontzer, Herman; Raichlen, David A; Wood, Brian M; Emery Thompson, Melissa; Racette, Susan B; Mabulla, Audax Z P; Marlowe, Frank W

    2015-01-01

    Studies of total energy expenditure, (TEE; kcal/day) among traditional populations have challenged current models relating habitual physical activity to daily energy requirements. Here, we examine the relationship between physical activity and TEE among traditional Hadza hunter-gatherers living in northern Tanzania. Hadza adults were studied at two camps, with minimal intervention so as to monitor energy expenditure and activity during normal daily life. We measured daily walking distance and walking speed using wearable GPS units for 41 adults. For a subset of 30 adults, we measured TEE using doubly labeled water, three indices of work load (foraging return rate, maternal status, and number of dependent children), and urinary biomarkers of metabolic activity and stress (8-hydroxydeoxyguanosine, cortisol, and testosterone). Fat-free mass was the single strongest predictor of TEE among Hadza adults (r(2)  = 0.66, P < 0.001). Hadza men used greater daily walking distances and faster walking speeds compared with that of Hadza women, but neither sex nor any measure of physical activity or work load were correlated with TEE in analyses controlling for fat-free mass. Compared with developed, industrial populations, Hadza adults had similar TEE but elevated levels of metabolic stress as measured by 8-hydroxydeoxyguanosine. Our results indicate that daily physical activity may not predict TEE within traditional hunter-gatherer populations like the Hadza. Instead, adults with high levels of habitual physical activity may adapt by reducing energy allocation to other physiological activity. © 2015 Wiley Periodicals, Inc.

  18. Understanding the Nature of Measurement Error When Estimating Energy Expenditure and Physical Activity via Physical Activity Recall.

    PubMed

    Paul, David R; McGrath, Ryan; Vella, Chantal A; Kramer, Matthew; Baer, David J; Moshfegh, Alanna J

    2018-03-26

    The National Health and Nutrition Examination Survey physical activity questionnaire (PAQ) is used to estimate activity energy expenditure (AEE) and moderate to vigorous physical activity (MVPA). Bias and variance in estimates of AEE and MVPA from the PAQ have not been described, nor the impact of measurement error when utilizing the PAQ to predict biomarkers and categorize individuals. The PAQ was administered to 385 adults to estimate AEE (AEE:PAQ) and MVPA (MVPA:PAQ), while simultaneously measuring AEE with doubly labeled water (DLW; AEE:DLW) and MVPA with an accelerometer (MVPA:A). Although AEE:PAQ [3.4 (2.2) MJ·d -1 ] was not significantly different from AEE:DLW [3.6 (1.6) MJ·d -1 ; P > .14], MVPA:PAQ [36.2 (24.4) min·d -1 ] was significantly higher than MVPA:A [8.0 (10.4) min·d -1 ; P < .0001]. AEE:PAQ regressed on AEE:DLW and MVPA:PAQ regressed on MVPA:A yielded not only significant positive relationships but also large residual variances. The relationships between AEE and MVPA, and 10 of the 12 biomarkers were underestimated by the PAQ. When compared with accelerometers, the PAQ overestimated the number of participants who met the Physical Activity Guidelines for Americans. Group-level bias in AEE:PAQ was small, but large for MVPA:PAQ. Poor within-participant estimates of AEE:PAQ and MVPA:PAQ lead to attenuated relationships with biomarkers and misclassifications of participants who met or who did not meet the Physical Activity Guidelines for Americans.

  19. Science Activities in Energy: Electrical Energy.

    ERIC Educational Resources Information Center

    Oak Ridge Associated Universities, TN.

    Presented is a science activities in energy package which includes 16 activities relating to electrical energy. Activities are simple, concrete experiments for fourth, fifth and sixth grades which illustrate principles and problems relating to energy. Each activity is outlined in a single card which is introduced by a question. A teacher's…

  20. More physically active and leaner adolescents have higher energy intake.

    PubMed

    Cuenca-García, Magdalena; Ortega, Francisco B; Ruiz, Jonatan R; Labayen, Idoia; Moreno, Luis A; Patterson, Emma; Vicente-Rodríguez, Germán; González-Gross, Marcela; Marcos, Ascensión; Polito, Angela; Manios, Yannis; Beghin, Laurent; Huybrechts, Inge; Wästlund, Acki; Hurtig-Wennlöf, Anita; Hagströmer, Maria; Molnár, Dénes; Widhalm, Kurt; Kafatos, Anthony; De Henauw, Stefaan; Castillo, Manuel J; Gutin, Bernard; Sjöström, Michael

    2014-01-01

    To test whether youths who engage in vigorous physical activity are more likely to have lean bodies while ingesting relatively large amounts of energy. For this purpose, we studied the associations of both physical activity and adiposity with energy intake in adolescents. The study subjects were adolescents who participated in 1 of 2 cross-sectional studies, the Healthy Lifestyle in Europe by Nutrition in Adolescence (HELENA) study (n = 1450; mean age, 14.6 years) or the European Youth Heart Study (EYHS; n = 321; mean age, 15.6 years). Physical activity was measured by accelerometry, and energy intake was measured by 24-hour recall. In the HELENA study, body composition was assessed by 2 or more of the following methods: skinfold thickness, bioelectrical impedance analysis, plus dual-energy X-ray absorptiometry or air-displacement plethysmography in a subsample. In the EYHS, body composition was assessed by skinfold thickness. Fat mass was inversely associated with energy intake in both studies and using 4 different measurement methods (P ≤ .006). Overall, fat-free mass was positively associated with energy intake in both studies, yet the results were not consistent across measurement methods in the HELENA study. Vigorous physical activity in the HELENA study (P < .05) and moderate physical activity in the EYHS (P < .01) were positively associated with energy intake. Overall, results remained unchanged after adjustment for potential confounding factors, after mutual adjustment among the main exposures (physical activity and fat mass), and after the elimination of obese subjects, who might tend to underreport energy intake, from the analyses. Our data are consistent with the hypothesis that more physically active and leaner adolescents have higher energy intake than less active adolescents with larger amounts of fat mass. Copyright © 2014 Mosby, Inc. All rights reserved.

  1. SU-E-T-543: Measurement of Neutron Activation From Different High Energy Varian Linear Accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thatcher, T; Madsen, S; Sudowe, R

    2015-06-15

    Purpose: Linear accelerators producing photons above 10 MeV may induce photonuclear reactions in high Z components of the accelerator. These liberated neutrons can then activate the structural components of the accelerator and other materials in the beam path through neutron capture reactions. The induced activity within the accelerator may contribute to additional dose to both patients and personnel. This project seeks to determine the total activity and activity per activated isotope following irradiation in different Varian accelerators at energies above 10 MeV. Methods: A Varian 21IX accelerator was used to irradiate a 30 cm × 30 cm × 20 cmmore » solid water phantom with 15 MV x-rays. The phantom was placed at an SSD of 100 cm and at the center of a 20 cm × 20 cm field. Activation induced gamma spectra were acquired over a 5 minute interval after 1 and 15 minutes from completion of the irradiation. All measurements were made using a CANBERRA Falcon 5000 Portable HPGe detector. The majority of measurements were made in scattering geometry with the detector situated at 90° to the incident beam, 30 cm from the side of the phantom and approximately 10 cm from the top. A 5 minute background count was acquired and automatically subtracted from all subsequent measurements. Photon spectra were acquired for both open and MLC fields. Results: Based on spectral signatures, nuclides have been identified and their activities calculated for both open and MLC fields. Preliminary analyses suggest that activities from the activation products in the microcurie range. Conclusion: Activation isotopes have been identified and their relative activities determined. These activities are only gross estimates since efficiencies have not been determined for this source-detector geometry. Current efforts are focused on accurate determination of detector efficiencies using Monte Carlo calculations.« less

  2. Collision activity during training increases total energy expenditure measured via doubly labelled water.

    PubMed

    Costello, Nessan; Deighton, Kevin; Preston, Thomas; Matu, Jamie; Rowe, Joshua; Sawczuk, Thomas; Halkier, Matt; Read, Dale B; Weaving, Daniel; Jones, Ben

    2018-06-01

    Collision sports are characterised by frequent high-intensity collisions that induce substantial muscle damage, potentially increasing the energetic cost of recovery. Therefore, this study investigated the energetic cost of collision-based activity for the first time across any sport. Using a randomised crossover design, six professional young male rugby league players completed two different 5-day pre-season training microcycles. Players completed either a collision (COLL; 20 competitive one-on-one collisions) or non-collision (nCOLL; matched for kinematic demands, excluding collisions) training session on the first day of each microcycle, exactly 7 days apart. All remaining training sessions were matched and did not involve any collision-based activity. Total energy expenditure was measured using doubly labelled water, the literature gold standard. Collisions resulted in a very likely higher (4.96 ± 0.97 MJ; ES = 0.30 ± 0.07; p = 0.0021) total energy expenditure across the 5-day COLL training microcycle (95.07 ± 16.66 MJ) compared with the nCOLL training microcycle (90.34 ± 16.97 MJ). The COLL training session also resulted in a very likely higher (200 ± 102 AU; ES = 1.43 ± 0.74; p = 0.007) session rating of perceived exertion and a very likely greater (- 14.6 ± 3.3%; ES = - 1.60 ± 0.51; p = 0.002) decrease in wellbeing 24 h later. A single collision training session considerably increased total energy expenditure. This may explain the large energy expenditures of collision-sport athletes, which appear to exceed kinematic training and match demands. These findings suggest fuelling professional collision-sport athletes appropriately for the "muscle damage caused" alongside the kinematic "work required".

  3. The Limit of Magnetic-Shear Energy in Solar Active Regions

    NASA Technical Reports Server (NTRS)

    Moore, Ronald; Falconer, David; Sterling, Alphonse

    2012-01-01

    It has been found previously, by measuring from active-region magnetograms a proxy of the free energy in the active region's magnetic field, (1) that there is a sharp upper limit to the free energy the field can hold that increases with the amount of magnetic field in the active region, the active region's magnetic flux content, and (2) that most active regions are near this limit when their field explodes in a coronal mass ejection/flare eruption. That is, explosive active regions are concentrated in a main-sequence path bordering the free-energy-limit line in (flux content, free-energy proxy) phase space. Here, we present evidence that specifies the underlying magnetic condition that gives rise to the free-energy limit and the accompanying main sequence of explosive active regions. Using a suitable free-energy proxy measured from vector magnetograms of 44 active regions, we find evidence that (1) in active regions at and near their free-energy limit, the ratio of magnetic-shear free energy to the non-free magnetic energy the potential field would have is of the order of one in the core field, the field rooted along the neutral line, and (2) this ratio is progressively less in active regions progressively farther below their free-energy limit. Evidently, most active regions in which this core-field energy ratio is much less than one cannot be triggered to explode; as this ratio approaches one, most active regions become capable of exploding; and when this ratio is one, most active regions are compelled to explode.

  4. The Limit of Magnetic-Shear Energy in Solar Active Regions

    NASA Technical Reports Server (NTRS)

    Moore, Ronald L.; Falconer, David A.; Sterling, Alphonse C.

    2013-01-01

    It has been found previously, by measuring from active ]region magnetograms a proxy of the free energy in the active region fs magnetic field, (1) that there is a sharp upper limit to the free energy the field can hold that increases with the amount of magnetic field in the active region, the active region fs magnetic flux content, and (2) that most active regions are near this limit when their field explodes in a CME/flare eruption. That is, explosive active regions are concentrated in a main ]sequence path bordering the free ]energy ]limit line in (flux content, free ]energy proxy) phase space. Here we present evidence that specifies the underlying magnetic condition that gives rise to the free ]energy limit and the accompanying main sequence of explosive active regions. Using a suitable free energy proxy measured from vector magnetograms of 44 active regions, we find evidence that (1) in active regions at and near their free ]energy limit, the ratio of magnetic ]shear free energy to the non ]free magnetic energy the potential field would have is of order 1 in the core field, the field rooted along the neutral line, and (2) this ratio is progressively less in active regions progressively farther below their free ]energy limit. Evidently, most active regions in which this core ]field energy ratio is much less than 1 cannot be triggered to explode; as this ratio approaches 1, most active regions become capable of exploding; and when this ratio is 1, most active regions are compelled to explode.

  5. Effects of activation energy and activation volume on the temperature-dependent viscosity of water.

    PubMed

    Kwang-Hua, Chu Rainer

    2016-08-01

    Water transport in a leaf is vulnerable to viscosity-induced changes. Recent research has suggested that these changes may be partially due to variation at the molecular scale, e.g., regulations via aquaporins, that induce reductions in leaf hydraulic conductance. What are the quantitative as well as qualitative changes in temperature-dependent viscosity due to the role of aquaporins in tuning activation energy and activation volume? Using the transition-state approach as well as the boundary perturbation method, we investigate temperature-dependent viscosity tuned by activation energy and activation volume. To validate our approach, we compare our numerical results with previous temperature-dependent viscosity measurements. The rather good fit between our calculations and measurements confirms our present approach. We have obtained critical parameters for the temperature-dependent (shear) viscosity of water that might be relevant to the increasing and reducing of leaf hydraulic conductance. These parameters are sensitive to temperature, activation energy, and activation volume. Once the activation energy increases, the (shear) viscosity of water increases. Our results also show that as the activation volume increases (say, 10^{-23}m^{3}), the (shear) viscosity of water decreases significantly and the latter induces the enhancing of leaf hydraulic conductance. Within the room-temperature regime, a small increase in the activation energy will increase the water viscosity or reduce the leaf hydraulic conductance. Our approach and results can be applied to diverse plant or leaf attributes.

  6. Physical activity recommendations: an alternative approach using energy expenditure.

    PubMed

    Mudd, Lanay M; Rafferty, Ann P; Reeves, Mathew J; Pivarnik, James M

    2008-10-01

    Most adults do not meet the American College of Sports Medicine and Centers for Disease Control and Prevention (ACSM/CDC) physical activity recommendations. Even fewer meet the more extreme Institute of Medicine (IOM) physical activity recommendations. Compliance with either recommendation has been conventionally assessed by combining frequencies and durations of self-reported activities. Leisure-time energy expenditure is a cumulative measure of activity that offers an alternative method of defining compliance. To calculate the leisure-time energy expenditure of adults complying with the ACSM/CDC or the IOM physical activity recommendations determined by conventional measures and to reexamine compliance with the IOM recommendation using energy expenditure criteria. National, cross-sectional data from the 2000 Behavioral Risk Factor Surveillance System determined the mode, frequency, and duration of up to two leisure-time activities performed by adults. Four mutually exclusive activity groups (Non-, Low-, ACSM/CDC-, and IOM-Active) were defined on the basis of frequencies and durations of reported activities. Leisure-time energy expenditure (kcal x kg(-1) x wk(-1)) was calculated per respondent. The energy expenditure threshold for meeting the IOM recommendation was calculated as 21 kcal x kg(-1) x wk(-1). Of the 162,669 respondents included in the analyses, 29.9% were Nonactive, whereas 42.3%, 23.3%, and 4.5% were Low-, ACSM/CDC-, and IOM-Active, respectively. Median leisure-time energy expenditure values were 9.0, 27.4, and 63.0 kcal x kg(-1) x wk(-1) for Low-, ACSM/CDC-, and IOM-Active groups, respectively. When using energy expenditure criteria, compliance with the IOM recommendation rose to 27.7% of respondents. Compliance with the IOM physical activity recommendation dramatically increased when assessed by energy expenditure compared with conventional criteria, thereby highlighting the potential bias of conventional methods. A significant proportion of adults

  7. A measurement error model for physical activity level as measured by a questionnaire with application to the 1999-2006 NHANES questionnaire.

    PubMed

    Tooze, Janet A; Troiano, Richard P; Carroll, Raymond J; Moshfegh, Alanna J; Freedman, Laurence S

    2013-06-01

    Systematic investigations into the structure of measurement error of physical activity questionnaires are lacking. We propose a measurement error model for a physical activity questionnaire that uses physical activity level (the ratio of total energy expenditure to basal energy expenditure) to relate questionnaire-based reports of physical activity level to true physical activity levels. The 1999-2006 National Health and Nutrition Examination Survey physical activity questionnaire was administered to 433 participants aged 40-69 years in the Observing Protein and Energy Nutrition (OPEN) Study (Maryland, 1999-2000). Valid estimates of participants' total energy expenditure were also available from doubly labeled water, and basal energy expenditure was estimated from an equation; the ratio of those measures estimated true physical activity level ("truth"). We present a measurement error model that accommodates the mixture of errors that arise from assuming a classical measurement error model for doubly labeled water and a Berkson error model for the equation used to estimate basal energy expenditure. The method was then applied to the OPEN Study. Correlations between the questionnaire-based physical activity level and truth were modest (r = 0.32-0.41); attenuation factors (0.43-0.73) indicate that the use of questionnaire-based physical activity level would lead to attenuated estimates of effect size. Results suggest that sample sizes for estimating relationships between physical activity level and disease should be inflated, and that regression calibration can be used to provide measurement error-adjusted estimates of relationships between physical activity and disease.

  8. Daily energy expenditure by five-year-old children, measured by doubly labeled water.

    PubMed

    Fontvieille, A M; Harper, I T; Ferraro, R T; Spraul, M; Ravussin, E

    1993-08-01

    Current recommendations for daily energy requirements in 5-year-old children (90 kcal/kg per day) are based on energy intake associated with normal growth. It is not known, however, how these recommendations compare with total free-living energy expenditure (TEE) and how much of TEE is related to physical activity. The TEE and the resting metabolic rate (RMR) were measured in 28 white children, aged 5 years (15 boys, 13 girls; mean (+/- SD) weight 20.1 +/- 3.4 kg; height 113 +/- 6 cm; fat 20% +/- 5%). The TEE was calculated during a 7-day period from urinary elimination rates of deuterium (2H) and heavy oxygen (18O) by using a modification of the two-point slope-intercept method; RMR was measured by a ventilated-hood indirect calorimeter. Physical activity indexes were also collected from questionnaires completed by the parents. Measured TEE was considerably lower than the recommended dietary allowances (1370 +/- 222 kcal/day vs 1807 +/- 310 kcal/day; p < 0.0001), whereas measured RMR was slightly higher than predicted RMR (1001 +/- 119 kcal/day vs 952 +/- 78 kcal/day; p < 0.001). The energy cost of physical activity accounted for only 16% +/- 7% of TEE. An index of activity, assessed as the difference between the measured TEE and the predicted TEE, correlated positively with past-year sport-leisure activity assessed by questionnaire (r = 0.40; p < 0.05). We conclude that measured TEE in 5-year-old children yields lower values (approximately 400 kcal/day) than current estimates. A minute part of this difference (20 to 30 kcal/day) is related to the changes in energy stores during growth, but most seems due to lower-than-expected levels of physical activity. This might be related to increased television viewing, which replaces activities requiring energy.

  9. Science Activities in Energy: Wind Energy.

    ERIC Educational Resources Information Center

    Oak Ridge Associated Universities, TN.

    Included in this science activities energy package are 12 activities related to wind energy for elementary students. Each activity is outlined on a single card and is introduced by a question. Topics include: (1) At what time of day is there enough wind to make electricity where you live?; (2) Where is the windiest spot on your schoolground?; and…

  10. The Maximum Free Magnetic Energy Allowed in a Solar Active Region

    NASA Technical Reports Server (NTRS)

    Moore, Ronald L.; Falconer, David A.

    2009-01-01

    Two whole-active-region magnetic quantities that can be measured from a line-of-sight magnetogram are (sup L) WL(sub SG), a gauge of the total free energy in an active region's magnetic field, and sup L(sub theta), a measure of the active region's total magnetic flux. From these two quantities measured from 1865 SOHO/MDI magnetograms that tracked 44 sunspot active regions across the 0.5 R(sub Sun) central disk, together with each active region's observed production of CMEs, X flares, and M flares, Falconer et al (2009, ApJ, submitted) found that (1) active regions have a maximum attainable free magnetic energy that increases with the magnetic size (sup L) (sub theta) of the active region, (2) in (Log (sup L)WL(sub SG), Log(sup L) theta) space, CME/flare-productive active regions are concentrated in a straight-line main sequence along which the free magnetic energy is near its upper limit, and (3) X and M flares are restricted to large active regions. Here, from (a) these results, (b) the observation that even the greatest X flares produce at most only subtle changes in active region magnetograms, and (c) measurements from MSFC vector magnetograms and from MDI line-of-sight magnetograms showing that practically all sunspot active regions have nearly the same area-averaged magnetic field strength: =- theta/A approximately equal to 300 G, where theta is the active region's total photospheric flux of field stronger than 100 G and A is the area of that flux, we infer that (1) the maximum allowed ratio of an active region's free magnetic energy to its potential-field energy is 1, and (2) any one CME/flare eruption releases no more than a small fraction (less than 10%) of the active region's free magnetic energy. This work was funded by NASA's Heliophysics Division and NSF's Division of Atmospheric Sciences.

  11. Playing active video games increases energy expenditure in children.

    PubMed

    Graf, Diana L; Pratt, Lauren V; Hester, Casey N; Short, Kevin R

    2009-08-01

    To compare energy expenditure rates in children playing the physically active video games, Dance Dance Revolution (DDR) and Nintendo's Wii Sports in relation to treadmill walking. Energy expenditure, heart rate, step rate, and perceived exertion were measured in 14 boys and 9 girls (ages 10-13 years; BMI at 3-98th percentile for age and gender) while watching television at rest, playing DDR at 2 skill levels, playing Wii bowling and boxing, and walking at 2.6, 4.2, and 5.7 km/h. Arterial elasticity was measured at rest and immediately after gaming. Compared with watching television, energy expenditure while gaming or walking increased 2- to 3-fold. Similarly, high rates of energy expenditure, heart rate, and perceived exertion were elicited from playing Wii boxing, DDR level 2, or walking at 5.7 km/h. This occurred despite variations in step rate among activities, reflecting greater use of upper body during Wii play (lowest step rate) than during walking (highest step rate) or DDR play. Wii bowling and beginner level DDR elicited a 2-fold increase in energy expenditure compared to television watching. Large-artery elasticity declined immediately after both DDR and Wii. The change was inversely related to the increment in energy expenditure above rest achieved during the activity. Energy expenditure during active video game play is comparable to moderate-intensity walking. Thus, for children who spend considerable time playing electronic screen games for entertainment, physically active games seem to be a safe, fun, and valuable means of promoting energy expenditure.

  12. Employing Magnetic Levitation to Monitor Reaction Kinetics and Measure Activation Energy

    ERIC Educational Resources Information Center

    Benz, Lauren; Cesafsky, Karen E.; Le, Tran; Park, Aileen; Malicky, David

    2012-01-01

    This article describes a simple and inexpensive undergraduate-level kinetics experiment that uses magnetic levitation to monitor the progress and determine the activation energy of a condensation reaction on a polymeric solid support. The method employs a cuvette filled with a paramagnetic solution positioned between two strong magnets. The…

  13. Changing Conceptions of Activation Energy.

    ERIC Educational Resources Information Center

    Pacey, Philip D.

    1981-01-01

    Provides background material which relates to the concept of activation energy, fundamental in the study of chemical kinetics. Compares the related concepts of the Arrhenius activation energy, the activation energy at absolute zero, the enthalpy of activation, and the threshold energy. (CS)

  14. Constrained Total Energy Expenditure and Metabolic Adaptation to Physical Activity in Adult Humans.

    PubMed

    Pontzer, Herman; Durazo-Arvizu, Ramon; Dugas, Lara R; Plange-Rhule, Jacob; Bovet, Pascal; Forrester, Terrence E; Lambert, Estelle V; Cooper, Richard S; Schoeller, Dale A; Luke, Amy

    2016-02-08

    Current obesity prevention strategies recommend increasing daily physical activity, assuming that increased activity will lead to corresponding increases in total energy expenditure and prevent or reverse energy imbalance and weight gain [1-3]. Such Additive total energy expenditure models are supported by exercise intervention and accelerometry studies reporting positive correlations between physical activity and total energy expenditure [4] but are challenged by ecological studies in humans and other species showing that more active populations do not have higher total energy expenditure [5-8]. Here we tested a Constrained total energy expenditure model, in which total energy expenditure increases with physical activity at low activity levels but plateaus at higher activity levels as the body adapts to maintain total energy expenditure within a narrow range. We compared total energy expenditure, measured using doubly labeled water, against physical activity, measured using accelerometry, for a large (n = 332) sample of adults living in five populations [9]. After adjusting for body size and composition, total energy expenditure was positively correlated with physical activity, but the relationship was markedly stronger over the lower range of physical activity. For subjects in the upper range of physical activity, total energy expenditure plateaued, supporting a Constrained total energy expenditure model. Body fat percentage and activity intensity appear to modulate the metabolic response to physical activity. Models of energy balance employed in public health [1-3] should be revised to better reflect the constrained nature of total energy expenditure and the complex effects of physical activity on metabolic physiology. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Engagement, enjoyment, and energy expenditure during active video game play

    PubMed Central

    Lyons, Elizabeth J.; Tate, Deborah F.; Ward, Dianne S.; Ribisl, Kurt M.; Bowling, J. Michael; Kalyanaraman, Sriram

    2014-01-01

    Objective Playing active video games can produce moderate levels of physical activity, but little is known about how these games motivate players to be active. Several psychological predictors, such as perceptions of competence, control, and engagement, may be associated with enjoyment of a game, which has in turn been hypothesized to predict energy expended during play. However, these relationships have yet to be tested in active video games. Methods Young adults aged 18–35 (N = 97, 50 female) < 300 pounds played a Dance Dance Revolution game for 13 minutes while energy expenditure was measured using indirect calorimetry. Self-reported measures of engagement, perceived competence, perceived control, and enjoyment were taken immediately afterwards. Mediation was analyzed using path analysis. Results A path model in which enjoyment mediated the effects of engagement, perceived competence, and perceived control on energy expenditure and BMI directly affected energy expenditure was an adequate fit to the data, χ2(1, N = 97) = .199, p = .655; CFI = 1.00; RMSEA < .001; 90% CI = .000 - .206; p = .692. Enjoyment mediated the relationship between engagement and energy expenditure (indirect effect = .138, p = .028), but other mediated effects were not significant. Conclusion Engagement, enjoyment, and BMI affect energy expended during active video game play. Games that are more enjoyable and engaging may produce greater intensity activity. Developers, practitioners, and researchers should consider characteristics that influence these predictors when creating or recommending active video games. PMID:23527520

  16. Energy saving and recovery measures in integrated urban water systems

    NASA Astrophysics Data System (ADS)

    Freni, Gabriele; Sambito, Mariacrocetta

    2017-11-01

    The present paper describes different energy production, recovery and saving measures which can be applied in an integrated urban water system. Production measures are often based on the installation of photovoltaic systems; the recovery measures are commonly based on hydraulic turbines, exploiting the available pressure potential to produce energy; saving measures are based on substitution of old pumps with higher efficiency ones. The possibility of substituting some of the pipes of the water supply system can be also considered in a recovery scenario in order to reduce leakages and recovery part of the energy needed for water transport and treatment. The reduction of water losses can be obtained through the Active Leakage Control (ALC) strategies resulting in a reduction in energy consumption and in environmental impact. Measures were applied to a real case study to tested it the efficiency, i.e., the integrated urban water system of the Palermo metropolitan area in Sicily (Italy).

  17. Comparison of measured versus predicted energy requirements in critically ill cancer patients.

    PubMed

    Pirat, Arash; Tucker, Anne M; Taylor, Kim A; Jinnah, Rashida; Finch, Clarence G; Canada, Todd D; Nates, Joseph L

    2009-04-01

    Accurate determination of caloric requirements is essential to avoid feeding-associated complications in critically ill patients. In critically ill cancer patients we compared the measured and estimated resting energy expenditures. All patients admitted to the oncology intensive care unit between March 2004 and July 2005 were considered for inclusion. For those patients enrolled (n = 34) we measured resting energy expenditure via indirect calorimetry, and estimated resting energy expenditure in 2 ways: clinically estimated resting energy expenditure; and the Harris-Benedict basal energy expenditure equation. Clinically estimated resting energy expenditure was associated with underfeeding, appropriate feeding, and overfeeding in approximately 15%, 15%, and 71% of the patients, respectively. The Harris-Benedict basal energy expenditure was associated with underfeeding, appropriate feeding, and overfeeding in approximately 29%, 41%, and 29% of the patients, respectively. The mean measured resting energy expenditure (1,623 +/- 384 kcal/d) was similar to the mean Harris-Benedict basal energy expenditure without the addition of stress or activity factors (1,613 +/- 382 kcal/d, P = .87), and both were significantly lower than the mean clinically estimated resting energy expenditure (1,862 +/- 330 kcal/d, P < or = .003 for both). There was a significant correlation only between mean measured resting energy expenditure and mean Harris-Benedict basal energy expenditure (P < .001), but the correlation coefficient between those values was low (r = 0.587). Underfeeding and overfeeding were common in our critically ill cancer patients when resting energy expenditure was estimated rather than measured. Indirect calorimetry is the method of choice for determining caloric need in critically ill cancer patients, but if indirect calorimetry is not available or feasible, the Harris-Benedict equation without added stress and activity factors is more accurate than the clinically

  18. Measurements of the Activation Energies for Atomic Hydrogen Diffusion on Pure Solid CO

    NASA Astrophysics Data System (ADS)

    Kimura, Y.; Tsuge, M.; Pirronello, V.; Kouchi, A.; Watanabe, N.

    2018-05-01

    The diffusion of hydrogen atoms on dust grains is a key process in the formation of interstellar H2 and some hydrogenated molecules such as formaldehyde and methanol. We investigate the adsorption and diffusion of H atoms on pure solid CO as an analog of dust surfaces observed toward some cold interstellar regions. Using a combination of photostimulated desorption and resonance-enhanced multiphoton ionization methods to detect H atoms directly, the relative adsorption probabilities and diffusion coefficients of the H atoms are measured on pure solid CO at 8, 12, and 15 K. There is little difference between the diffusion coefficients of the hydrogen and deuterium atoms, indicating that the diffusion is limited by thermal hopping. The activation energies controlling the H-atom diffusion depend on the surface temperature, and values of 22, 30, and ∼37 meV were obtained for 8, 12, and 15 K, respectively.

  19. Well-Being Tracking via Smartphone-Measured Activity and Sleep: Cohort Study.

    PubMed

    DeMasi, Orianna; Feygin, Sidney; Dembo, Aluma; Aguilera, Adrian; Recht, Benjamin

    2017-10-05

    Automatically tracking mental well-being could facilitate personalization of treatments for mood disorders such as depression and bipolar disorder. Smartphones present a novel and ubiquitous opportunity to track individuals' behavior and may be useful for inferring and automatically monitoring mental well-being. The aim of this study was to assess the extent to which activity and sleep tracking with a smartphone can be used for monitoring individuals' mental well-being. A cohort of 106 individuals was recruited to install an app on their smartphone that would track their well-being with daily surveys and track their behavior with activity inferences from their phone's accelerometer data. Of the participants recruited, 53 had sufficient data to infer activity and sleep measures. For this subset of individuals, we related measures of activity and sleep to the individuals' well-being and used these measures to predict their well-being. We found that smartphone-measured approximations for daily physical activity were positively correlated with both mood (P=.004) and perceived energy level (P<.001). Sleep duration was positively correlated with mood (P=.02) but not energy. Our measure for sleep disturbance was not found to be significantly related to either mood or energy, which could imply too much noise in the measurement. Models predicting the well-being measures from the activity and sleep measures were found to be significantly better than naive baselines (P<.01), despite modest overall improvements. Measures of activity and sleep inferred from smartphone activity were strongly related to and somewhat predictive of participants' well-being. Whereas the improvement over naive models was modest, it reaffirms the importance of considering physical activity and sleep for predicting mood and for making automatic mood monitoring a reality. ©Orianna DeMasi, Sidney Feygin, Aluma Dembo, Adrian Aguilera, Benjamin Recht. Originally published in JMIR Mhealth and Uhealth (http

  20. Well-Being Tracking via Smartphone-Measured Activity and Sleep: Cohort Study

    PubMed Central

    Feygin, Sidney; Dembo, Aluma; Aguilera, Adrian; Recht, Benjamin

    2017-01-01

    Background Automatically tracking mental well-being could facilitate personalization of treatments for mood disorders such as depression and bipolar disorder. Smartphones present a novel and ubiquitous opportunity to track individuals’ behavior and may be useful for inferring and automatically monitoring mental well-being. Objective The aim of this study was to assess the extent to which activity and sleep tracking with a smartphone can be used for monitoring individuals’ mental well-being. Methods A cohort of 106 individuals was recruited to install an app on their smartphone that would track their well-being with daily surveys and track their behavior with activity inferences from their phone’s accelerometer data. Of the participants recruited, 53 had sufficient data to infer activity and sleep measures. For this subset of individuals, we related measures of activity and sleep to the individuals’ well-being and used these measures to predict their well-being. Results We found that smartphone-measured approximations for daily physical activity were positively correlated with both mood (P=.004) and perceived energy level (P<.001). Sleep duration was positively correlated with mood (P=.02) but not energy. Our measure for sleep disturbance was not found to be significantly related to either mood or energy, which could imply too much noise in the measurement. Models predicting the well-being measures from the activity and sleep measures were found to be significantly better than naive baselines (P<.01), despite modest overall improvements. Conclusions Measures of activity and sleep inferred from smartphone activity were strongly related to and somewhat predictive of participants’ well-being. Whereas the improvement over naive models was modest, it reaffirms the importance of considering physical activity and sleep for predicting mood and for making automatic mood monitoring a reality. PMID:28982643

  1. Science Activities in Energy: Solar Energy II.

    ERIC Educational Resources Information Center

    Oak Ridge Associated Universities, TN.

    Included in this science activities energy package are 14 activities related to solar energy for secondary students. Each activity is outlined on a single card and is introduced by a question such as: (1) how much solar heat comes from the sun? or (2) how many times do you have to run water through a flat-plate collector to get a 10 degree rise in…

  2. The Magnetic Free Energy in Active Regions

    NASA Technical Reports Server (NTRS)

    Metcalf, Thomas R.; Mickey, Donald L.; LaBonte, Barry J.

    2001-01-01

    The magnetic field permeating the solar atmosphere governs much of the structure, morphology, brightness, and dynamics observed on the Sun. The magnetic field, especially in active regions, is thought to provide the power for energetic events in the solar corona, such as solar flares and Coronal Mass Ejections (CME) and is believed to energize the hot coronal plasma seen in extreme ultraviolet or X-rays. The question remains what specific aspect of the magnetic flux governs the observed variability. To directly understand the role of the magnetic field in energizing the solar corona, it is necessary to measure the free magnetic energy available in active regions. The grant now expiring has demonstrated a new and valuable technique for observing the magnetic free energy in active regions as a function of time.

  3. Activities Handbook for Energy Education.

    ERIC Educational Resources Information Center

    DeVito, Alfred; Krockover, Gerald H.

    The purpose of this handbook is to present information about energy and to translate this information into learning activities for children. Chapter 1, "Energy: A Delicate Dilemma," presents activities intended to provide an introduction to energy and energy usage. Chapter 2, "What are the Sources of Energy?" provides…

  4. Energy Storage. Teachers Guide. Science Activities in Energy.

    ERIC Educational Resources Information Center

    Jacobs, Mary Lynn, Ed.

    Included in this science activities energy package for students in grades 4-10 are 12 activities related to energy storage. Each activity is outlined on the front and back of a single sheet and is introduced by a key question. Most of the activities can be completed in the classroom with materials readily available in any community. Among the…

  5. Effects of Charge State on Fragmentation Pathways, Dynamics, and Activation Energies of Ubiquitin Ions Measured by Blackbody Infrared Radiative Dissociation

    PubMed Central

    Jockusch, Rebecca A.; Schnier, Paul D.; Price, William D.; Strittmatter, Eric. F.; Demirev, Plamen A.; Williams*, Evan R.

    2005-01-01

    Blackbody infrared radiative dissociation spectra of the (M + 5H)5+ through (M + 11H)11+ ions of the protein ubiquitin (8.6 kDa) formed by electrospray ionization were measured in a Fourier-transform mass spectrometer. The 5+ ion dissociates exclusively by loss of water and/or ammonia, whereas the 11+ charge state dissociates only by formation of complementary y and b ions. These two processes are competitive for intermediate charge state ions, with the formation of y and b ions increasingly favored for the higher charge states. The y and b ions are formed by cleavage of the backbone amide bond on the C-terminal side of acidic residues exclusively, with cleavage adjacent to aspartic acid favored. Thermal unimolecular dissociation rate constants for the dissociation of each of these charge states were measured. From the temperature dependence of these rates, Arrhenius activation parameters in the rapid energy exchange limit are obtained. The activation energies (Ea) and preexponential factors (A) for the 5+, 8+, and 9+ ions are 1.2 eV and 1012 s−1, respectively. These values for the 6+ and 7+ ions are 0.9–1.0 eV and 109 s−1, and those for the 10+ and 11+ ions are 1.6 eV and 1016–1017 s−1. Thus, with the exception of the 5+ ion, the higher charge states of ubiquitin have larger dissociation activation energies than the lower charge states. The different A factors observed for production of y and b ions from different precursor charge states indicate that they are formed by different mechanisms, ranging from relatively complex rearrangements to direct bond cleavages. These results clearly demonstrate that the relative dissociation rates of large biomolecule ions by themselves are not necessarily a reliable indicator of their relative dissociation energies, even when similar fragment ions are formed. PMID:9075403

  6. Effects of charge state on fragmentation pathways, dynamics, and activation energies of ubiquitin ions measured by blackbody infrared radiative dissociation.

    PubMed

    Jockusch, R A; Schnier, P D; Price, W D; Strittmatter, E F; Demirev, P A; Williams, E R

    1997-03-15

    Blackbody infrared radiative dissociation spectra of the (M + 5H)5+ through (M + 11H)11+ ions of the protein ubiquitin (8.6 kDa) formed by electrospray ionization were measured in a Fourier-transform mass spectrometer. The 5+ ion dissociates exclusively by loss of water and/or ammonia, whereas the 11+ charge state dissociates only by formation of complementary y and b ions. These two processes are competitive for intermediate charge state ions, with the formation of y and b ions increasingly favored for the higher charge states. The y and b ions are formed by cleavage of the backbone amide bond on the C-terminal side of acidic residues exclusively, with cleavage adjacent to aspartic acid favored. Thermal unimolecular dissociation rate constants for the dissociation of each of these charge states were measured. From the temperature dependence of these rates, Arrhenius activation parameters in the rapid energy exchange limit are obtained. The activation energies (Ea) and preexponential factors (A) for the 5+, 8+, and 9+ ions are 1.2 eV and 10(12) s-1, respectively. These values for the 6+ and 7+ ions are 0.9-1.0 eV and 10(9) s-1, and those for the 10+ and 11+ ions are 1.6 eV and 10(16)-10(17) s-1. Thus, with the exception of the 5+ ion, the higher charge states of ubiquitin have larger dissociation activation energies than the lower charge states. The different A factors observed for production of y and b ions from different precursor charge states indicate that they are formed by different mechanisms, ranging from relatively complex rearrangements to direct bond cleavages. These results clearly demonstrate that the relative dissociation rates of large biomolecule ions by themselves are not necessarily a reliable indicator of their relative dissociation energies, even when similar fragment ions are formed.

  7. A new, simple and precise method for measuring cyclotron proton beam energies using the activity vs. depth profile of zinc-65 in a thick target of stacked copper foils.

    PubMed

    Asad, A H; Chan, S; Cryer, D; Burrage, J W; Siddiqui, S A; Price, R I

    2015-11-01

    The proton beam energy of an isochronous 18MeV cyclotron was determined using a novel version of the stacked copper-foils technique. This simple method used stacked foils of natural copper forming 'thick' targets to produce Zn radioisotopes by the well-documented (p,x) monitor-reactions. Primary beam energy was calculated using the (65)Zn activity vs. depth profile in the target, with the results obtained using (62)Zn and (63)Zn (as comparators) in close agreement. Results from separate measurements using foil thicknesses of 100, 75, 50 or 25µm to form the stacks also concurred closely. Energy was determined by iterative least-squares comparison of the normalized measured activity profile in a target-stack with the equivalent calculated normalized profile, using 'energy' as the regression variable. The technique exploits the uniqueness of the shape of the activity vs. depth profile of the monitor isotope in the target stack for a specified incident energy. The energy using (65)Zn activity profiles and 50-μm foils alone was 18.03±0.02 [SD] MeV (95%CI=17.98-18.08), and 18.06±0.12MeV (95%CI=18.02-18.10; NS) when combining results from all isotopes and foil thicknesses. When the beam energy was re-measured using (65)Zn and 50-μm foils only, following a major upgrade of the ion sources and nonmagnetic beam controls the results were 18.11±0.05MeV (95%CI=18.00-18.23; NS compared with 'before'). Since measurement of only one Zn monitor isotope is required to determine the normalized activity profile this indirect yet precise technique does not require a direct beam-current measurement or a gamma-spectroscopy efficiency calibrated with standard sources, though a characteristic photopeak must be identified. It has some advantages over published methods using the ratio of cross sections of monitor reactions, including the ability to determine energies across a broader range and without need for customized beam degraders. Copyright © 2015 Elsevier Ltd. All rights

  8. On the possibility of negative activation energies in bimolecular reactions

    NASA Technical Reports Server (NTRS)

    Jaffe, R. L.

    1978-01-01

    The temperature dependence of the rate constants for model reacting systems was studied to understand some recent experimental measurements which imply the existence of negative activation energies. A collision theory model and classical trajectory calculations are used to demonstrate that the reaction probability can vary inversely with collision energy for bimolecular reactions occurring on attractive potential energy surfaces. However, this is not a sufficient condition to ensure that the rate constant has a negative temperature dependence. On the basis of these calculations, it seems unlikely that a true bimolecular reaction between neutral molecules will have a negative activation energy.

  9. Energy Adventure Center. Activity Book.

    ERIC Educational Resources Information Center

    Carlton, Linda L.

    Energy activities are provided in this student activity book. They include: (1) an energy walk; (2) forms of energy in the home; (3) energy conversion; (4) constructing a solar hot dog cooker (with instructions for drawing a parabola); (5) interviewing senior citizens to learn about energy use in the past; (6) packaging materials; (7) insulation;…

  10. Automatic energy expenditure measurement for health science.

    PubMed

    Catal, Cagatay; Akbulut, Akhan

    2018-04-01

    It is crucial to predict the human energy expenditure in any sports activity and health science application accurately to investigate the impact of the activity. However, measurement of the real energy expenditure is not a trivial task and involves complex steps. The objective of this work is to improve the performance of existing estimation models of energy expenditure by using machine learning algorithms and several data from different sensors and provide this estimation service in a cloud-based platform. In this study, we used input data such as breathe rate, and hearth rate from three sensors. Inputs are received from a web form and sent to the web service which applies a regression model on Azure cloud platform. During the experiments, we assessed several machine learning models based on regression methods. Our experimental results showed that our novel model which applies Boosted Decision Tree Regression in conjunction with the median aggregation technique provides the best result among other five regression algorithms. This cloud-based energy expenditure system which uses a web service showed that cloud computing technology is a great opportunity to develop estimation systems and the new model which applies Boosted Decision Tree Regression with the median aggregation provides remarkable results. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Comparative validity of physical activity measures in older adults.

    PubMed

    Colbert, Lisa H; Matthews, Charles E; Havighurst, Thomas C; Kim, Kyungmann; Schoeller, Dale A

    2011-05-01

    To compare the validity of various physical activity measures with doubly labeled water (DLW)-measured physical activity energy expenditure (PAEE) in free-living older adults. Fifty-six adults aged ≥65 yr wore three activity monitors (New Lifestyles pedometer, ActiGraph accelerometer, and a SenseWear (SW) armband) during a 10-d free-living period and completed three different surveys (Yale Physical Activity Survey (YPAS), Community Health Activities Model Program for Seniors (CHAMPS), and a modified Physical Activity Scale for the Elderly (modPASE)). Total energy expenditure was measured using DLW, resting metabolic rate was measured with indirect calorimetry, the thermic effect of food was estimated, and from these, estimates of PAEE were calculated. The degree of linear association between the various measures and PAEE was assessed, as were differences in group PAEE, when estimable by a given measure. All three monitors were significantly correlated with PAEE (r=0.48-0.60, P<0.001). Of the questionnaires, only CHAMPS was significantly correlated with PAEE (r=0.28, P=0.04). Statistical comparison of the correlations suggested that the monitors were superior to YPAS and modPASE. Mean squared errors for all correlations were high, and the median PAEE from the different tools was significantly different from DLW for all but the YPAS and regression-estimated PAEE from the ActiGraph. Objective devices more appropriately rank PAEE than self-reported instruments in older adults, but absolute estimates of PAEE are not accurate. Given the cost differential and ease of use, pedometers seem most useful in this population when ranking by physical activity level is adequate. © 2011 by the American College of Sports Medicine

  12. Physical Activity Energy Expenditure and Sarcopenia in Black South African Urban Women.

    PubMed

    Kruger, Herculina S; Havemann-Nel, Lize; Ravyse, Chrisna; Moss, Sarah J; Tieland, Michael

    2016-03-01

    Black women are believed to be genetically less predisposed to age-related sarcopenia. The objective of this study was to investigate lifestyle factors associated with sarcopenia in black South African (SA) urban women. In a cross-sectional study, 247 women (mean age 57 y) were randomly selected. Anthropometric and sociodemographic variables, dietary intakes, and physical activity were measured. Activity was also measured by combined accelerometery/heart rate monitoring (ActiHeart), and HIV status was tested. Dual energy x-ray absorptiometry was used to measure appendicular skeletal mass (ASM). Sarcopenia was defined according to a recently derived SA cutpoint of ASM index (ASM/height squared) < 4.94 kg/m(2). In total, 8.9% of the women were sarcopenic, decreasing to 8.1% after exclusion of participants who were HIV positive. In multiple regressions with ASM index, grip strength, and gait speed, respectively, as dependent variables, only activity energy expenditure (β = .27) was significantly associated with ASM index. Age (β = -.50) and activity energy expenditure (β = .17) were significantly associated with gait speed. Age (β = -.11) and lean mass (β = .21) were significantly associated with handgrip strength. Sarcopenia was prevalent among these SA women and was associated with low physical activity energy expenditure.

  13. Remote Determination of Auroral Energy Characteristics During Substorm Activity

    NASA Technical Reports Server (NTRS)

    Germany, G. A.; Parks, G. K.; Brittnacher, M. J.; Cumnock, J.; Lummerzheim, D.; Spann, J. F., Jr.

    1997-01-01

    Ultraviolet auroral images from the Ultraviolet Imager onboard the POLAR satellite can be used as quantitative remote diagnostics of the auroral regions, yielding estimates of incident energy characteristics, compositional changes, and other higher order data products. In particular, images of long and short wavelength N2 Lyman-Birge-Hopfield (LBH) emissions can be modeled to obtain functions of energy flux and average energy that are basically insensitive to changes in seasonal and solar activity changes. This technique is used in this study to estimate incident electron energy flux and average energy during substorm activity occurring on May 19, 1996. This event was simultaneously observed by WIND, GEOTAIL, INTERBALL, DMSP and NOAA spacecraft as well as by POLAR. Here incident energy estimates derived from Ultraviolet Imager (UVI) are compared with in situ measurements of the same parameters from an overflight by the DMSP F12 satellite coincident with the UVI image times.

  14. In-use measurement of activity, energy use, and emissions of a plug-in hybrid electric vehicle.

    PubMed

    Graver, Brandon M; Frey, H Christopher; Choi, Hyung-Wook

    2011-10-15

    Plug-in hybrid electric vehicles (PHEVs) could reduce transportation air emissions and energy use. However, a method is needed for estimating on-road emissions of PHEVs. To develop a framework for quantifying microscale energy use and emissions (EU&E), measurements were conducted on a Toyota Prius retrofitted with a plug-in battery system on eight routes. Measurements were made using the following: (1) a data logger for the hybrid control system; (2) a portable emissions measurement system; and (3) a global positioning system with barometric altimeter. Trends in EU&E are estimated based on vehicle specific power. Energy economy is quantified based on gasoline consumed by the engine and grid energy consumed by the plug-in battery. Emissions from electricity consumption are estimated based on the power generation mix. Fuel use is approximately 30% lower during plug-in battery use. Grid emissions were higher for CO₂, NO(x), SO₂, and PM compared to tailpipe emissions but lower for CO and hydrocarbons. EU&E depends on engine and plug-in battery operation. The use of two energy sources must be addressed in characterizing fuel economy; overall energy economy is 11% lower if including grid energy use than accounting only for fuel consumption.

  15. The Energy Spectra of Heavy Nuclei Measured by the ATIC Experiment

    NASA Technical Reports Server (NTRS)

    Panov, A. D.; Adams, J. H.; Ahn, H. S.; Bashindzhagyan, G. L.; Batkov, K. E.; Chang, J.; Christl, M.; Fazley, A. R.; Ganel, O.; Gunasingha, R. M.

    2004-01-01

    ATIC (Advanced Thin Ionization Calorimeter) is a balloon-borne experiment to measure the spectra and composition of primary cosmic rays in the region of total energy from 100 GeV to near 100 TeV for Z from 1 to 26. ATIC consists of a pixelated silicon matrix detector to measure charge plus a fully active BGO calorimeter, to measure energy, located below a carbon target interleaved with three layers of scintillator hodoscope. The ATIC instrument had a second (scientific) flight from McMurdo, Antarctica from 12/29/02 to 1/18/03, yielding 20 days of good data. The GEANT 3.21 Monte Carlo code with the QGSM event generator and the FLUKA code with the DPMJET-II event generator were used to convert energy deposition measurements to primary energy. We present the preliminary energy spectra for the abundant elements C, O, Ne, Mg, Si and Fe and compare them with the results of the first (test) flight of ATIC in 2000-01 and with results from the HEAO-3 and CRN experiments.

  16. ACTIVITY ENERGY EXPENDITURE AND INCIDENT COGNITIVE IMPAIRMENT IN OLDER ADULTS

    PubMed Central

    Middleton, Laura E.; Manini, Todd M.; Simonsick, Eleanor M.; Harris, Tamara B.; Barnes, Deborah E.; Tylavsky, Frances; Brach, Jennifer S.; Everhart, James E.; Yaffe, Kristine

    2013-01-01

    Introduction Studies suggest that physically active people have reduced risk of incident cognitive impairment in late life. However, these studies are limited by reliance on subjective self-reports of physical activity, which only moderately correlate to objective measures and often exclude activity not readily quantifiable by frequency and duration. The objective of this study was to investigate the relationship between activity energy expenditure (AEE), an objective measure of total activity, and incidence of cognitive impairment. Methods We calculated AEE as 90% of total energy expenditure (assessed over two weeks using doubly-labeled water) minus resting metabolic rate (measured using indirect calorimetry) in 197 men and women (mean 74.8 years) who were free of mobility and cognitive impairments at study baseline (1998–2000). Cognitive function was assessed at baseline and 2 or 5 years later using the Modified Mini-Mental State Examination (3MS). Cognitive impairment was defined as a decline of >1.0 SD (9 points) between baseline and follow-up. Results After adjustment for baseline 3MS, demographics, fat free mass, sleep duration, self-reported health, and diabetes, older adults in the highest sex-specific tertile of AEE had lower odds of incident cognitive impairment than those in the lowest tertile (OR, 95% CI 0.09, 0.01–0.79). There was also a significant dose response between AEE and incidence of cognitive impairment (p-for-trend over tertiles=0.05). Conclusions These findings indicate that greater activity energy expenditure may be protective against cognitive impairment in a dose-response manner. The significance of overall activity in contrast to vigorous or light activity should be determined. PMID:21771893

  17. ERP Energy and Cognitive Activity Correlates

    NASA Astrophysics Data System (ADS)

    Schillaci, Michael Jay; Vendemia, Jennifer M. C.

    2014-03-01

    We propose a novel analysis approach for high-density event related scalp potential (ERP) data where the integrated channel-power is used to attain an energy density functional state for channel-clusters of neurophysiological significance. The method is applied to data recorded during a two-stimulus, directed lie paradigm and shows that deceptive responses emit between 8% and 10% less power. A time course analysis of these cognitive activity measures over posterior and anterior regions of the cortex suggests that neocortical interactions, reflecting the differing workload demands during executive and semantic processes, take about 50% longer for the case of deception. These results suggest that the proposed method may provide a useful tool for the analysis of ERP correlates of high-order cognitive functioning. We also report on a possible equivalence between the energy functional distribution and near-infrared signatures that have been measured with other modalities.

  18. Energy homeostasis and running wheel activity during pregnancy in the mouse.

    PubMed

    Ladyman, S R; Carter, K M; Grattan, D R

    2018-05-05

    Pregnancy and lactation are metabolically challenging states, where the mother must supply all the energy requirements for the developing fetus and growing pups respectively. The aim of the current study was to characterize many aspects of energy homeostasis before and during pregnancy in the mouse, and to examine the role of voluntary activity on changes in energy expenditure during pregnancy. In a secondary aim, we evaluate measures of energy homeostasis during pregnancy in mice that successfully reared their litter or in mice that went on to abandon their litter, to determine if an impairment in pregnancy-induced adaptation of energy homeostasis might underlie the abandonment of pups soon after birth. During pregnancy, food intake was increased, characterized by increased meal size and duration but not number of meals per day. The duration of time spent inactive, predicted to indicate sleep behaviour, was increased both early and late in pregnancy compared to pre-pregnancy levels. Increased x + y beam breaks, as a measure of activity increased during pregnancy and this reflected an increase in ambulatory behaviour in mid pregnancy and an increase in non-ambulatory movement in late pregnancy. Energy expenditure, as measured by indirect calorimetry, increased across pregnancy, likely due to the growth and development of fetal tissue. There was also a dramatic reduction in voluntary wheel running as soon as the mice became pregnant. Compared with successful pregnancies and lactations, pregnancies where pups were abandoned soon after birth were associated with reduced body weight gain and an increase in running wheel activity at the end of pregnancy, but no difference in food intake or energy expenditure. Overall, during pregnancy there are multiple adaptations to change energy homeostasis, resulting in partitioning of provisions of energy to the developing fetus and storing energy for future metabolic demands. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Proton and Electron Threshold Energy Measurements for Extravehicular Activity Space Suits. Chapter 2

    NASA Technical Reports Server (NTRS)

    Moyers, M. F.; Nelson, G. D.; Saganti, P. B.

    2003-01-01

    Construction of ISS will require more than 1000 hours of EVA. Outside of ISS during EVA, astronauts and cosmonauts are likely to be exposed to a large fluence of electrons and protons. Development of radiation protection guidelines requires the determination of the minimum energy of electrons and protons that penetrate the suits at various locations. Measurements of the water-equivalent thickness of both US. and Russian EVA suits were obtained by performing CT scans. Specific regions of interest of the suits were further evaluated using a differential range shift technique. This technique involved measuring thickness ionization curves for 6-MeV electron and 155-MeV proton beams with ionization chambers using a constant source-to-detector distance. The thicknesses were obtained by stacking polystyrene slabs immediately upstream of the detector. The thicknesses of the 50% ionizations relative to the maximum ionizations were determined. The detectors were then placed within the suit and the stack thickness adjusted until the 50% ionization was reestablished. The difference in thickness between the 50% thicknesses was then used with standard range-energy tables to determine the threshold energy for penetration. This report provides a detailed description of the experimental arrangement and results.

  20. Results on the neutron energy distribution measurements at the RECH-1 Chilean nuclear reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aguilera, P., E-mail: paguilera87@gmail.com; Romero-Barrientos, J.; Universidad de Chile, Dpto. de Física, Facultad de Ciencias, Las Palmeras 3425, Nuñoa, Santiago

    2016-07-07

    Neutron activations experiments has been perform at the RECH-1 Chilean Nuclear Reactor to measure its neutron flux energy distribution. Samples of pure elements was activated to obtain the saturation activities for each reaction. Using - ray spectroscopy we identify and measure the activity of the reaction product nuclei, obtaining the saturation activities of 20 reactions. GEANT4 and MCNP was used to compute the self shielding factor to correct the cross section for each element. With the Expectation-Maximization algorithm (EM) we were able to unfold the neutron flux energy distribution at dry tube position, near the RECH-1 core. In this work,more » we present the unfolding results using the EM algorithm.« less

  1. A system for measuring thermal activation energy levels in silicon by thermally stimulated capacitance

    NASA Technical Reports Server (NTRS)

    Cockrum, R. H.

    1982-01-01

    One method being used to determine energy level(s) and electrical activity of impurities in silicon is described. The method is called capacitance transient spectroscopy (CTS). It can be classified into three basic categories: the thermally stimulated capacitance method, the voltage-stimulated capacitance method, and the light-stimulated capacitance method; the first two categories are discussed. From the total change in capacitance and the time constant of the capacitance response, emission rates, energy levels, and trap concentrations can be determined. A major advantage of using CTS is its ability to detect the presence of electrically active impurities that are invisible to other techniques, such as Zeeman effect atomic absorption, and the ability to detect more than one electrically active impurity in a sample. Examples of detection of majority and minority carrier traps from gold donor and acceptor centers in silicon using the capacitance transient spectrometer are given to illustrate the method and its sensitivity.

  2. Energy Expenditure and Intensity of Active Video Games in Children and Adolescents.

    PubMed

    Canabrava, Karina L R; Faria, Fernanda R; Lima, Jorge R P de; Guedes, Dartagnan P; Amorim, Paulo R S

    2018-03-01

    This study aimed to compare the energy expenditure and intensity of active video games to that of treadmill walking in children and adolescents. Seventy-two boys and girls (aged 8-13 years) were recruited from local public schools. Energy expenditure and heart rate were measured during rest, during 3-km/hr, 4-km/hr, and 5-km/hr walks, and during active games (Adventure, Boxing I, Boxing II, and Dance). During walking and active games, we also assessed physical activity using an accelerometer. The energy expenditure of the active games Adventure, Boxing I, Boxing II, and Dance was similar to that of treadmill walking at 5 km/hr in boys and girls. Heart rate was significantly higher for the game Adventure compared with walking at 3 km/hr, 4 km/hr, and 5 km/hr and the game Dance in both genders. The heart rate of girls during the games Adventure and Dance was significantly higher compared with boys. There was a statistically significant difference (p < .05, with an effect size ranging from 0.40 to 3.54) in the counts·min -1 , measured through accelerometry, between activities. XBOX 360 Kinect games provide energy expenditure and physical activity of moderate intensity for both genders. The use of active video games can be an interesting alternative to increase physical activity levels.

  3. Active cell mechanics: Measurement and theory.

    PubMed

    Ahmed, Wylie W; Fodor, Étienne; Betz, Timo

    2015-11-01

    Living cells are active mechanical systems that are able to generate forces. Their structure and shape are primarily determined by biopolymer filaments and molecular motors that form the cytoskeleton. Active force generation requires constant consumption of energy to maintain the nonequilibrium activity to drive organization and transport processes necessary for their function. To understand this activity it is necessary to develop new approaches to probe the underlying physical processes. Active cell mechanics incorporates active molecular-scale force generation into the traditional framework of mechanics of materials. This review highlights recent experimental and theoretical developments towards understanding active cell mechanics. We focus primarily on intracellular mechanical measurements and theoretical advances utilizing the Langevin framework. These developing approaches allow a quantitative understanding of nonequilibrium mechanical activity in living cells. This article is part of a Special Issue entitled: Mechanobiology. Copyright © 2015. Published by Elsevier B.V.

  4. Photocatalytic Active Radiation Measurements and Use

    NASA Technical Reports Server (NTRS)

    Davis, Bruce A.; Underwood, Lauren W.

    2011-01-01

    Photocatalytic materials are being used to purify air, to kill microbes, and to keep surfaces clean. A wide variety of materials are being developed, many of which have different abilities to absorb various wavelengths of light. Material variability, combined with both spectral illumination intensity and spectral distribution variability, will produce a wide range of performance results. The proposed technology estimates photocatalytic active radiation (PcAR), a unit of radiation that normalizes the amount of light based on its spectral distribution and on the ability of the material to absorb that radiation. Photocatalytic reactions depend upon the number of electron-hole pairs generated at the photocatalytic surface. The number of electron-hole pairs produced depends on the number of photons per unit area per second striking the surface that can be absorbed and whose energy exceeds the bandgap of the photocatalytic material. A convenient parameter to describe the number of useful photons is the number of moles of photons striking the surface per unit area per second. The unit of micro-einsteins (or micromoles) of photons per m2 per sec is commonly used for photochemical and photoelectric-like phenomena. This type of parameter is used in photochemistry, such as in the conversion of light energy for photosynthesis. Photosynthetic response correlates with the number of photons rather than by energy because, in this photochemical process, each molecule is activated by the absorption of one photon. In photosynthesis, the number of photons absorbed in the 400 700 nm spectral range is estimated and is referred to as photosynthetic active radiation (PAR). PAR is defined in terms of the photosynthetic photon flux density measured in micro-einsteins of photons per m2 per sec. PcAR is an equivalent, similarly modeled parameter that has been defined for the photocatalytic processes. Two methods to measure the PcAR level are being proposed. In the first method, a calibrated

  5. New Method for Measuring the Anchoring Energy of Strongly-Bound Membrane-Associated Proteins [Method for measuring the anchoring energy of strongly-bound membrane-associated proteins].

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kent, Michael S.; La Bauve, Elisa; Vernon, Briana C.

    Here, we describe a new method to measure the activation energy required to remove a strongly-bound membrane-associated protein from a lipid membrane (anchoring energy). It is based on measuring the rate of release of a liposome-bound protein during centrifugation on a sucrose gradient as a function of time and temperature. The method was used to determine anchoring energy for the soluble dengue virus envelope protein (sE) strongly bound to 80:20 POPC:POPG liposomes at pH 5.5. We also measured the binding energy of sE at the same pH for the initial, predominantly reversible, phase of binding to a 70:30 PC:PG lipidmore » bilayer. The anchoring energy (37 +/- 1.7 kcal/mol, 20% PG) was found to be much larger than the binding energy (7.8 +/- 0.3 kcal/mol for 30% PG, or est. 7.0 kcal/mol for 20% PG). This is consistent with data showing that free sE is a monomer at pH 5.5, but assembles into trimers after associating with membranes. But, trimerization alone is insufficient to account for the observed difference in energies, and we conclude that some energy dissipation occurs during the release process. This new method to determine anchoring energy should be useful to understand the complex interactions of integral monotopic proteins and strongly-bound peripheral membrane proteins with lipid membranes.« less

  6. New Method for Measuring the Anchoring Energy of Strongly-Bound Membrane-Associated Proteins [Method for measuring the anchoring energy of strongly-bound membrane-associated proteins].

    DOE PAGES

    Kent, Michael S.; La Bauve, Elisa; Vernon, Briana C.; ...

    2016-02-01

    Here, we describe a new method to measure the activation energy required to remove a strongly-bound membrane-associated protein from a lipid membrane (anchoring energy). It is based on measuring the rate of release of a liposome-bound protein during centrifugation on a sucrose gradient as a function of time and temperature. The method was used to determine anchoring energy for the soluble dengue virus envelope protein (sE) strongly bound to 80:20 POPC:POPG liposomes at pH 5.5. We also measured the binding energy of sE at the same pH for the initial, predominantly reversible, phase of binding to a 70:30 PC:PG lipidmore » bilayer. The anchoring energy (37 +/- 1.7 kcal/mol, 20% PG) was found to be much larger than the binding energy (7.8 +/- 0.3 kcal/mol for 30% PG, or est. 7.0 kcal/mol for 20% PG). This is consistent with data showing that free sE is a monomer at pH 5.5, but assembles into trimers after associating with membranes. But, trimerization alone is insufficient to account for the observed difference in energies, and we conclude that some energy dissipation occurs during the release process. This new method to determine anchoring energy should be useful to understand the complex interactions of integral monotopic proteins and strongly-bound peripheral membrane proteins with lipid membranes.« less

  7. [Energy requirements in active elderly individuals living in a rural region of Northwest Mexico].

    PubMed

    Alemán-Mateo, H; Reza-Durán, G T; Esparza, J; Valencia, M E

    1999-06-01

    The energy requirements in free-living elderly rural people were investigated by measuring physical activity level and basal energy expenditure using a physical activity questionnaire and indirect calorimetry, respectively. Approximately 65 different occupational and leisure activities over the previous 12 months were considered. Energy expenditure by physical activity was estimated using PAL for specific activities reported in the literature. All 65 the activities were considered to adapt the questionnaire. Reproducibility was evaluated by administering the questionnaire on two separate occasions within 3-4 week elapsed between them. It was found to be reliable for the study (Pearson correlation was r = 0.85; p < 0.05). The physical activity level of the women and men were 1.50 +/- 0.29 and 1.65 +/- 0.66, respectively (p < 0.05). The basal metabolic rate also differed between women and men (p < 0.05) with 5348 +/- 719 kJ/day and 6160 +/- 862 kJ/day, respectively. Similarly the total energy expenditure was different (p < 0.05) in women and men 8311 +/- 1610 kJ/day and 10,210 +/- 2268 kJ/day, respectively. Results indicate that the physical activity questionnaire presented can be an alternative methodology to estimate physical activity in free-living elderly people and together with indirect calorimetry measurements can be useful to estimate their energy expenditure and hence energy requirements.

  8. Measurement of the energy of horizontal cosmic ray muons

    NASA Astrophysics Data System (ADS)

    Gettert, Michael

    1993-03-01

    An experiment in which the energy of cosmic ray muons is determined by measuring the electron positron pairs that they radiate off when passing through matter is described. The detector is a stack of lead converters interspersed with ionization chambers for particle detection. The chambers use as active medium the liquid tetra methyl silane (TMS). The radiated quanta initiate electromagnetic cascades in the lead and are recognized due to the characteristic shower development. The energy spectrum of horizontal muons is presented and from this the primary cosmic ray spectrum is deduced.

  9. C&RE-SLC: Database for conservation and renewable energy activities

    NASA Astrophysics Data System (ADS)

    Cavallo, J. D.; Tompkins, M. M.; Fisher, A. G.

    1992-08-01

    The Western Area Power Administration (Western) requires all its long-term power customers to implement programs that promote the conservation of electric energy or facilitate the use of renewable energy resources. The hope is that these measures could significantly reduce the amount of environmental damage associated with electricity production. As part of preparing the environmental impact statement for Western's Electric Power Marketing Program, Argonne National Laboratory constructed a database of the conservation and renewable energy activities in which Western's Salt Lake City customers are involved. The database provides information on types of conservation and renewable energy activities and allows for comparisons of activities being conducted at different utilities in the Salt Lake City region. Sorting the database allows Western's Salt Lake City customers to be classified so the various activities offered by different classes of utilities can be identified; for example, comparisons can be made between municipal utilities and cooperatives or between large and small customers. The information included in the database was collected from customer planning documents in the files of Western's Salt Lake City office.

  10. Dietary intake, physical activity and energy expenditure of Malaysian adolescents.

    PubMed

    Zalilah, M S; Khor, G L; Mirnalini, K; Norimah, A K; Ang, M

    2006-06-01

    Paediatric obesity is a public health concern worldwide as it can track into adulthood and increase the risk of adult morbidity and mortality. While the aetiology of obesity is multi-factorial, the roles of diet and physical activity are controversial. Thus, the purpose of this study was to report on the differences in energy intake, diet composition, time spent doing physical activity and energy expenditure among underweight (UW), normal weight (NW) and at-risk of overweight (OW) Malaysian adolescents (317 females and 301 males) aged 11-15 years. This was a cross-sectional study with 6,555 adolescents measured for weights and heights for body mass index (BMI) categorisation. A total of 618 subjects were randomly selected from each BMI category according to gender. The subjects' dietary intake and physical activity were assessed using self-reported three-day food and activity records, respectively. Dietary intake components included total energy and macronutrient intakes. Energy expenditure was calculated as a sum of energy expended for basal metabolic rate and physical activity. Time spent (in minutes) in low, medium and high intensity activities was also calculated. The OW adolescents had the highest crude energy intake and energy expenditure. However, after adjusting for body weight, the OW subjects had the lowest energy intake and energy expenditure (p-value is less than 0.001). The study groups did not differ significantly in time spent for low, medium and high intensity activities. Macronutrient intakes differed significantly only among the girls where the OW group had the highest intakes compared to UW and NW groups (p-value is less than 0.05). All study groups had greater than 30 percent and less than 55 percent of energy intake from fat and carbohydrate, respectively. The data suggested that a combination of low energy expenditure adjusted for body weight and high dietary fat intake may be associated with overweight and obesity among adolescents. To

  11. Physical activity assessment: biomarkers and self-report of activity-related energy expenditure in the WHI.

    PubMed

    Neuhouser, Marian L; Di, Chongzhi; Tinker, Lesley F; Thomson, Cynthia; Sternfeld, Barbara; Mossavar-Rahmani, Yasmin; Stefanick, Marcia L; Sims, Stacy; Curb, J David; Lamonte, Michael; Seguin, Rebecca; Johnson, Karen C; Prentice, Ross L

    2013-03-15

    We used a biomarker of activity-related energy expenditure (AREE) to assess measurement properties of self-reported physical activity and to determine the usefulness of AREE regression calibration equations in the Women's Health Initiative. Biomarker AREE, calculated as the total energy expenditure from doubly labeled water minus the resting energy expenditure from indirect calorimetry, was assessed in 450 Women's Health Initiative participants (2007-2009). Self-reported AREE was obtained from the Arizona Activity Frequency Questionnaire (AAFQ), the 7-Day Physical Activity Recall (PAR), and the Women's Health Initiative Personal Habits Questionnaire (PHQ). Eighty-eight participants repeated the protocol 6 months later. Reporting error, measured as log(self-report AREE) minus log(biomarker AREE), was regressed on participant characteristics for each instrument. Body mass index was associated with underreporting on the AAFQ and PHQ but overreporting on PAR. Blacks and Hispanics underreported physical activity levels on the AAFQ and PAR, respectively. Underreporting decreased with age for the PAR and PHQ. Regressing logbiomarker AREE on logself-reported AREE revealed that self-report alone explained minimal biomarker variance (R(2) = 7.6, 4.8, and 3.4 for AAFQ, PAR, and PHQ, respectively). R(2) increased to 25.2, 21.5, and 21.8, respectively, when participant characteristics were included. Six-month repeatability data adjusted for temporal biomarker variation, improving R(2) to 79.4, 67.8, and 68.7 for AAFQ, PAR, and PHQ, respectively. Calibration equations "recover" substantial variation in average AREE and valuably enhance AREE self-assessment.

  12. 78 FR 7939 - Energy Conservation Program: Test Procedures for Microwave Ovens (Active Mode)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-04

    ...The U.S. Department of Energy (DOE) proposes to revise its test procedures for microwave ovens established under the Energy Policy and Conservation Act. The proposed amendments would add provisions for measuring the active mode energy use for microwave ovens, including both microwave-only ovens and convection microwave ovens. Specifically, DOE is proposing provisions for measuring the energy use of the microwave-only cooking mode for both microwave-only ovens and convection microwave ovens based on the testing methods in the latest draft version of the International Electrotechnical Commission Standard 60705, ``Household microwave ovens--Methods for measuring performance.'' DOE is proposing provisions for measuring the energy use of the convection-only cooking mode for convection microwave ovens based on the DOE test procedure for conventional ovens in our regulations. DOE is also proposing to calculate the energy use of the convection-microwave cooking mode for convection microwave ovens by apportioning the microwave-only mode and convection-only mode energy consumption measurements based on typical consumer use.

  13. Measuring Income and Projecting Energy Use

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pitcher, Hugh M.

    2009-11-01

    Abstract: Energy is a key requirement for a healthy, productive life and a major driver of the emissions leading to an increasingly warm planet. The implications of a doubling and redoubling of per capita incomes over the remainder of this century for energy use are a critical input into understanding the magnitude of the carbon management problem. A substantial controversy about how the Special Report on Emssions Scenarios (SRES) measured income and the potential implications of how income was measured for long term levels of energy use is revisited again in the McKibbin, Pearce and Stegman article appearing elsewhere inmore » this issue. The recent release of a new set of purchasing power estimates of national income, and the preparations for creating new scenarios to support the IPCC’s fifth assessment highlight the importance of the issues which have arisen surrounding income and energy use. Comparing the 1993 and 2005 ICP results on Purchasing Power Parity (PPP) based measures of income reveals that not only do the 2005 ICP estimates share the same issue of common growth rates for real income as measured by PPP and US $, but the lack of coherence in the estimates of PPP incomes, especially for developing countries raises yet another obstacle to resolving the best way to measure income. Further, the common use of an income term to mediate energy demand (as in the Kaya identity) obscures an underlying reality about per capita energy demands, leading to unreasonable estimates of the impact of changing income measures and of the recent high GDP growth rates in India and China. Significant new research is required to create both a reasonable set of GDP growth rates and long term levels of energy use.« less

  14. Energy expenditure while playing active and inactive video games.

    PubMed

    Leatherdale, Scott T; Woodruff, Sarah J; Manske, Stephen R

    2010-01-01

    To examine energy expenditure (EE) when playing active and inactive videogames (VG). Predicted EE was measured among 51 undergraduate students while playing active and inactive VG (Ontario, Canada). Predicted EE was significantly higher playing the active VG compared to the inactive VG according to heart rate monitor (97.4 kcal vs 64.7 kcal) and SenseWear armband (192.4 kcal vs 42.3 kcal) estimates. Active VG may be a viable intervention tool for increasing EE among students who would otherwise be spending time in sedentary screen-based behaviors.

  15. Energy Cost of Free-Play Activities in 10- to 11-Year-Old Children.

    PubMed

    Mackintosh, Kelly Alexandra; Ridley, Kate; Stratton, Gareth; Ridgers, Nicola D

    2016-06-01

    This study sought to ascertain the energy expenditure (EE) associated with different sedentary and physically active free-play activities in primary school-aged children. Twenty-eight children (13 boys; 11.4 ± 0.3 years; 1.45 ± 0.09 m; 20.0 ± 4.7 kg∙m-2) from 1 primary school in Northwest England engaged in 6 activities representative of children's play for 10 minutes (drawing, watching a DVD, playground games and free-choice) and 5 minutes (self-paced walking and jogging), with 5 minutes rest between each activity. Gas exchange variables were measured throughout. Resting energy expenditure was measured during 15 minutes of supine rest. Child (Schofield-predicted) MET values for watching a DVD, self-paced jogging and playing reaction ball were significantly higher for girls (P < .05). Utilizing a field-based protocol to examine children's free-living behaviors, these data contribute to the scarcity of information concerning children's EE during play to update the Compendium of Energy Expenditures for Youth.

  16. Measuring energy efficiency in economics: Shadow value approach

    NASA Astrophysics Data System (ADS)

    Khademvatani, Asgar

    For decades, academic scholars and policy makers have commonly applied a simple average measure, energy intensity, for studying energy efficiency. In contrast, we introduce a distinctive marginal measure called energy shadow value (SV) for modeling energy efficiency drawn on economic theory. This thesis demonstrates energy SV advantages, conceptually and empirically, over the average measure recognizing marginal technical energy efficiency and unveiling allocative energy efficiency (energy SV to energy price). Using a dual profit function, the study illustrates how treating energy as quasi-fixed factor called quasi-fixed approach offers modeling advantages and is appropriate in developing an explicit model for energy efficiency. We address fallacies and misleading results using average measure and demonstrate energy SV advantage in inter- and intra-country energy efficiency comparison. Energy efficiency dynamics and determination of efficient allocation of energy use are shown through factors impacting energy SV: capital, technology, and environmental obligations. To validate the energy SV, we applied a dual restricted cost model using KLEM dataset for the 35 US sectors stretching from 1958 to 2000 and selected a sample of the four sectors. Following the empirical results, predicted wedges between energy price and the SV growth indicate a misallocation of energy use in stone, clay and glass (SCG) and communications (Com) sectors with more evidence in the SCG compared to the Com sector, showing overshoot in energy use relative to optimal paths and cost increases from sub-optimal energy use. The results show that energy productivity is a measure of technical efficiency and is void of information on the economic efficiency of energy use. Decomposing energy SV reveals that energy, capital and technology played key roles in energy SV increases helping to consider and analyze policy implications of energy efficiency improvement. Applying the marginal measure, we also

  17. Diagnosis and characterization of mania: Quantifying increased energy and activity in the human behavioral pattern monitor

    PubMed Central

    Perry, William; McIlwain, Meghan; Kloezeman, Karen; Henry, Brook L.; Minassian, Arpi

    2016-01-01

    Increased energy or activity is now an essential feature of the mania of Bipolar Disorder (BD) according to DSM-5. This study examined whether objective measures of increased energy can differentiate manic BD individuals and provide greater diagnostic accuracy compared to rating scales, extending the work of previous studies with smaller samples. We also tested the relationship between objective measures of energy and rating scales. 50 hospitalized manic BD patients were compared to healthy subjects (HCS, n=39) in the human Behavioral Pattern Monitor (hBPM) which quantifies motor activity and goal-directed behavior in an environment containing novel stimuli. Archival hBPM data from 17 schizophrenia patients were used in sensitivity and specificity analyses. Manic BD patients exhibited higher motor activity than HCS and higher novel object interactions. hBPM activity measures were not correlated with observer-rated symptoms, and hBPM activity was more sensitive in accurately classifying hospitalized BD subjects than observer ratings. Although the findings can only be generalized to inpatient populations, they suggest that increased energy, particularly specific and goal-directed exploration, is a distinguishing feature of BD mania and is best quantified by objective measures of motor activity. A better understanding is needed of the biological underpinnings of this cardinal feature. PMID:27138818

  18. Applicability of self-activation of an NaI scintillator for measurement of photo-neutrons around a high-energy X-ray radiotherapy machine.

    PubMed

    Wakabayashi, Genichiro; Nohtomi, Akihiro; Yahiro, Eriko; Fujibuchi, Toshioh; Fukunaga, Junichi; Umezu, Yoshiyuki; Nakamura, Yasuhiko; Nakamura, Katsumasa; Hosono, Makoto; Itoh, Tetsuo

    2015-01-01

    The applicability of the activation of an NaI scintillator for neutron monitoring at a clinical linac was investigated experimentally. Thermal neutron fluence rates are derived by measurement of the I-128 activity generated in an NaI scintillator irradiated by neutrons; β-rays from I-128 are detected efficiently by the NaI scintillator. In order to verify the validity of this method for neutron measurement, we irradiated an NaI scintillator at a research reactor, and the neutron fluence rate was estimated. The method was then applied to neutron measurement at a 10-MV linac (Varian Clinac 21EX), and the neutron fluence rate was estimated at the isocenter and at 30 cm from the isocenter. When the scintillator was irradiated directly by high-energy X-rays, the production of I-126 was observed due to photo-nuclear reactions, in addition to the generation of I-128 and Na-24. From the results obtained by these measurements, it was found that the neutron measurement by activation of an NaI scintillator has a great advantage in estimates of a low neutron fluence rate by use of a quick measurement following a short-time irradiation. Also, the future application of this method to quasi real-time monitoring of neutrons during patient treatments at a radiotherapy facility is discussed, as well as the method of evaluation of the neutron dose.

  19. Body Segment Kinematics and Energy Expenditure in Active Videogames.

    PubMed

    Böhm, Birgit; Hartmann, Michael; Böhm, Harald

    2016-06-01

    Energy expenditure (EE) in active videogames (AVGs) is a component for assessing its benefit for cardiovascular health. Existing evidence suggests that AVGs are able to increase EE above rest and when compared with playing passive videogames. However, the association between body movement and EE remains unclear. Furthermore, for goal-directed game design, it is important to know the contribution of body segments to EE. This knowledge will help to acquire a certain level of exercise intensity during active gaming. Therefore, the purpose of this study was to determine the best predictors of EE from body segment energies, acceleration, and heart rate during different game situations. EE and body segment movement of 17 subjects, aged 22.1 ± 2.5 years, were measured in two different AVGs. In randomized order, the subjects played a handheld-controlled Nintendo(®) Wii™ tennis (NWT) game and a whole body-controlled Sony EyeToy(®) waterfall (ETW) game. Body segment movement was analyzed using a three-dimensional motion capture system. From the video data, mean values of mechanical energy change and acceleration of 10 body segments were analyzed. Measured EE was significantly higher in ETW (7.8 ± 1.4 metabolic equivalents [METs]) than in NWT (3.4 ± 1.0 METs). The best prediction parameter for the more intense ETW game was the energy change of the right thigh and for the less intense hand-controlled NWT game was the energy change of the upper torso. Segment acceleration was less accurate in predicting EE. The best predictors of metabolic EE were the thighs and the upper torso in whole body and handheld-controlled games, respectively. Increasing movement of these body segments would lead to higher physical activity intensity during gaming, reducing sedentary behavior.

  20. Neutron energy measurement for practical applications

    NASA Astrophysics Data System (ADS)

    Roshan, M. V.; Sadeghi, H.; Ghasabian, M.; Mazandarani, A.

    2018-03-01

    Industrial demand for neutrons constrains careful energy measurements. Elastic scattering of monoenergetic α -particles from neutron collision enables neutron energy measurement by calculating the amount of deviation from the position where collision takes place. The neutron numbers with specific energy is obtained by counting the number of α -particles in the corresponding location on the charged particle detector. Monte Carlo simulation and COMSOL Multiphysics5.2 are used to account for one-to-one collision of neutrons with α -particles.

  1. Energy balance measurement: when something is not better than nothing.

    PubMed

    Dhurandhar, N V; Schoeller, D; Brown, A W; Heymsfield, S B; Thomas, D; Sørensen, T I A; Speakman, J R; Jeansonne, M; Allison, D B

    2015-07-01

    Energy intake (EI) and physical activity energy expenditure (PAEE) are key modifiable determinants of energy balance, traditionally assessed by self-report despite its repeated demonstration of considerable inaccuracies. We argue here that it is time to move from the common view that self-reports of EI and PAEE are imperfect, but nevertheless deserving of use, to a view commensurate with the evidence that self-reports of EI and PAEE are so poor that they are wholly unacceptable for scientific research on EI and PAEE. While new strategies for objectively determining energy balance are in their infancy, it is unacceptable to use decidedly inaccurate instruments, which may misguide health-care policies, future research and clinical judgment. The scientific and medical communities should discontinue reliance on self-reported EI and PAEE. Researchers and sponsors should develop objective measures of energy balance.

  2. Development of an ATP measurement method suitable for xenobiotic treatment activated sludge biomass.

    PubMed

    Nguyen, Lan Huong; Chong, Nyuk-Min

    2015-09-01

    Activated sludge consumes a large amount of energy to degrade a xenobiotic organic compound. By tracking the energy inventory of activated sludge biomass during the sludge's degradation of a xenobiotic, any disadvantageous effect on the sludge's performance caused by energy deficiency can be observed. The purpose of this study was to develop a reliable and accurate method for measuring the ATP contents of activated sludge cells that were to degrade a xenobiotic organic. Cell disruption and cellular ATP extraction were performed by a protocol with which xenobiotic degrading activated sludge biomass was washed with SDS, treated by Tris and TCA, and followed by bead blasting. The suspension of disrupted cells was filtered before the filtrate was injected into HPLC that was set at optimal conditions to measure the ATP concentration therein. This extraction protocol and HPLC measurement of ATP was evaluated for its linearity, limits of detection, and reproducibility. Evaluation test results reported a R(2) of 0.999 of linear fit of ATP concentration versus activated sludge concentration, a LOD=0.00045mg/L, a LOQ=0.0015mg/L for HPLC measurement of ATP, a MDL=0.46mg/g SS for ATP extraction protocol, and a recovery efficiency of 96.4±2%. This method of ATP measurement was simple, rapid, reliable, and was unburdened of some limitations other methods may have. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Measuring physical activity in children and adolescents for dietary surveys: practicalities, problems and pitfalls.

    PubMed

    Mindell, Jennifer S; Coombs, Ngaire; Stamatakis, Emmanuel

    2014-05-01

    Physical inactivity is an important risk factor for many chronic diseases and contributes to obesity and poor mental well-being. The present paper describes the main advantages and disadvantages, practical problems, suggested uses, and future developments regarding self-reported and objective data collection in the context of dietary surveys. In dietary surveys, physical activity is measured primarily to estimate energy expenditure. Energy expenditure surveillance is important for tracking changes over time, particularly given the debates over the role of the relative importance of energy intake and expenditure changes in the aetiology of obesity. It is also important to assess the extent of underreporting of dietary intake in these surveys. Physical activity data collected should include details on the frequency, duration and relative intensity of activity for each activity type that contributes considerably to overall activity and energy expenditure. Problems of validity and reliability, associated with inaccurate assessment, recall bias, and social desirability bias, are well-known; children under 10 years cannot report their activities accurately. However, despite such limitations, questionnaires are still the dominant method of physical activity assessment in dietary surveys due to their low cost and relatively low participant burden. Objective, time-stamped measures that monitor heart rate and/or movement can provide more comprehensive, quantitative assessment of physical activity but at greater cost and participant burden. Although overcoming many limitations of questionnaires, objective measures also have drawbacks, including technical, practical and interpretational issues.

  4. Estimating activity energy expenditure: how valid are physical activity questionnaires?

    PubMed

    Neilson, Heather K; Robson, Paula J; Friedenreich, Christine M; Csizmadi, Ilona

    2008-02-01

    Activity energy expenditure (AEE) is the modifiable component of total energy expenditure (TEE) derived from all activities, both volitional and nonvolitional. Because AEE may affect health, there is interest in its estimation in free-living people. Physical activity questionnaires (PAQs) could be a feasible approach to AEE estimation in large populations, but it is unclear whether or not any PAQ is valid for this purpose. Our aim was to explore the validity of existing PAQs for estimating usual AEE in adults, using doubly labeled water (DLW) as a criterion measure. We reviewed 20 publications that described PAQ-to-DLW comparisons, summarized study design factors, and appraised criterion validity using mean differences (AEE(PAQ) - AEE(DLW), or TEE(PAQ) - TEE(DLW)), 95% limits of agreement, and correlation coefficients (AEE(PAQ) versus AEE(DLW) or TEE(PAQ) versus TEE(DLW)). Only 2 of 23 PAQs assessed most types of activity over the past year and indicated acceptable criterion validity, with mean differences (TEE(PAQ) - TEE(DLW)) of 10% and 2% and correlation coefficients of 0.62 and 0.63, respectively. At the group level, neither overreporting nor underreporting was more prevalent across studies. We speculate that, aside from reporting error, discrepancies between PAQ and DLW estimates may be partly attributable to 1) PAQs not including key activities related to AEE, 2) PAQs and DLW ascertaining different time periods, or 3) inaccurate assignment of metabolic equivalents to self-reported activities. Small sample sizes, use of correlation coefficients, and limited information on individual validity were problematic. Future research should address these issues to clarify the true validity of PAQs for estimating AEE.

  5. Uncertainty Estimation Improves Energy Measurement and Verification Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walter, Travis; Price, Phillip N.; Sohn, Michael D.

    2014-05-14

    Implementing energy conservation measures in buildings can reduce energy costs and environmental impacts, but such measures cost money to implement so intelligent investment strategies require the ability to quantify the energy savings by comparing actual energy used to how much energy would have been used in absence of the conservation measures (known as the baseline energy use). Methods exist for predicting baseline energy use, but a limitation of most statistical methods reported in the literature is inadequate quantification of the uncertainty in baseline energy use predictions. However, estimation of uncertainty is essential for weighing the risks of investing in retrofits.more » Most commercial buildings have, or soon will have, electricity meters capable of providing data at short time intervals. These data provide new opportunities to quantify uncertainty in baseline predictions, and to do so after shorter measurement durations than are traditionally used. In this paper, we show that uncertainty estimation provides greater measurement and verification (M&V) information and helps to overcome some of the difficulties with deciding how much data is needed to develop baseline models and to confirm energy savings. We also show that cross-validation is an effective method for computing uncertainty. In so doing, we extend a simple regression-based method of predicting energy use using short-interval meter data. We demonstrate the methods by predicting energy use in 17 real commercial buildings. We discuss the benefits of uncertainty estimates which can provide actionable decision making information for investing in energy conservation measures.« less

  6. Energy savings modelling of re-tuning energy conservation measures in large office buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fernandez, Nick; Katipamula, Srinivas; Wang, Weimin

    Today, many large commercial buildings use sophisticated building automation systems (BASs) to manage a wide range of building equipment. While the capabilities of BASs have increased over time, many buildings still do not fully use the BAS’s capabilities and are not properly commissioned, operated or maintained, which leads to inefficient operation, increased energy use, and reduced lifetimes of the equipment. This paper investigates the energy savings potential of several common HVAC system re-tuning measures on a typical large office building, using the Department of Energy’s building energy modeling software, EnergyPlus. The baseline prototype model uses roughly as much energy asmore » an average large office building in existing building stock, but does not utilize any re-tuning measures. Individual re-tuning measures simulated against this baseline include automatic schedule adjustments, damper minimum flow adjustments, thermostat adjustments, as well as dynamic resets (set points that change continuously with building and/or outdoor conditions) to static pressure, supply-air temperature, condenser water temperature, chilled and hot water temperature, and chilled and hot water differential pressure set points. Six combinations of these individual measures have been formulated – each designed to conform to limitations to implementation of certain individual measures that might exist in typical buildings. All the individual measures and combinations were simulated in 16 climate locations representative of specific U.S. climate zones. The modeling results suggest that the most effective energy savings measures are those that affect the demand-side of the building (air-systems and schedules). Many of the demand-side individual measures were capable of reducing annual total HVAC system energy consumption by over 20% in most cities that were modeled. Supply side measures affecting HVAC plant conditions were only modestly successful (less than 5% annual HVAC

  7. Experimental measurement of energy harvesting with backpack

    NASA Astrophysics Data System (ADS)

    Pavelkova, Radka; Vala, David; Suranek, Pavel; Mahdal, Miroslav

    2017-08-01

    This article deals with the energy harvesting systems, especially the energy harvesting backpack, which appears as a convenient means for energy harvesting for mobile sensors power. Before starting the experiment, it was necessary to verify whether this energy will be sufficient to get acquainted with the human kinematics and analyze problematics itself. For this purpose there was used motion capture technology from Xsens. Measured data on the position of a particle moving man and back when walking, these data were then used for experimental realization of energy harvesting backpack and as input data to the simulation in Simulink, which brought us a comparison between theoretical assumptions and practical implementation. When measuring characteristics of energy harvesting system we have a problem with measurements on backpack solved when redoing of the hydraulic cylinder as a source of a suitable movement corresponding to the amplitude and frequency of human walk.

  8. Estimating Physical Activity Energy Expenditure with the Kinect Sensor in an Exergaming Environment

    PubMed Central

    Nathan, David; Huynh, Du Q.; Rubenson, Jonas; Rosenberg, Michael

    2015-01-01

    Active video games that require physical exertion during game play have been shown to confer health benefits. Typically, energy expended during game play is measured using devices attached to players, such as accelerometers, or portable gas analyzers. Since 2010, active video gaming technology incorporates marker-less motion capture devices to simulate human movement into game play. Using the Kinect Sensor and Microsoft SDK this research aimed to estimate the mechanical work performed by the human body and estimate subsequent metabolic energy using predictive algorithmic models. Nineteen University students participated in a repeated measures experiment performing four fundamental movements (arm swings, standing jumps, body-weight squats, and jumping jacks). Metabolic energy was captured using a Cortex Metamax 3B automated gas analysis system with mechanical movement captured by the combined motion data from two Kinect cameras. Estimations of the body segment properties, such as segment mass, length, centre of mass position, and radius of gyration, were calculated from the Zatsiorsky-Seluyanov's equations of de Leva, with adjustment made for posture cost. GPML toolbox implementation of the Gaussian Process Regression, a locally weighted k-Nearest Neighbour Regression, and a linear regression technique were evaluated for their performance on predicting the metabolic cost from new feature vectors. The experimental results show that Gaussian Process Regression outperformed the other two techniques by a small margin. This study demonstrated that physical activity energy expenditure during exercise, using the Kinect camera as a motion capture system, can be estimated from segmental mechanical work. Estimates for high-energy activities, such as standing jumps and jumping jacks, can be made accurately, but for low-energy activities, such as squatting, the posture of static poses should be considered as a contributing factor. When translated into the active video gaming

  9. Energy Conservation Activity Packet, Grade 3.

    ERIC Educational Resources Information Center

    Bakke, Ruth

    This activity packet for grade 3 is one of a series developed in response to the concern for energy conservation. It contains activities that stress an energy conservation ethic and includes many values clarification activities for grade three. The packet is divided into two parts and provides the teacher with background information, concepts and…

  10. Diagnosis and characterization of mania: Quantifying increased energy and activity in the human behavioral pattern monitor.

    PubMed

    Perry, William; McIlwain, Meghan; Kloezeman, Karen; Henry, Brook L; Minassian, Arpi

    2016-06-30

    Increased energy or activity is now an essential feature of the mania of Bipolar Disorder (BD) according to DSM-5. This study examined whether objective measures of increased energy can differentiate manic BD individuals and provide greater diagnostic accuracy compared to rating scales, extending the work of previous studies with smaller samples. We also tested the relationship between objective measures of energy and rating scales. 50 hospitalized manic BD patients were compared to healthy subjects (HCS, n=39) in the human Behavioral Pattern Monitor (hBPM) which quantifies motor activity and goal-directed behavior in an environment containing novel stimuli. Archival hBPM data from 17 schizophrenia patients were used in sensitivity and specificity analyses. Manic BD patients exhibited higher motor activity than HCS and higher novel object interactions. hBPM activity measures were not correlated with observer-rated symptoms, and hBPM activity was more sensitive in accurately classifying hospitalized BD subjects than observer ratings. Although the findings can only be generalized to inpatient populations, they suggest that increased energy, particularly specific and goal-directed exploration, is a distinguishing feature of BD mania and is best quantified by objective measures of motor activity. A better understanding is needed of the biological underpinnings of this cardinal feature. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Activities of the Iowa Energy Policy Council in Energy Education.

    ERIC Educational Resources Information Center

    Heiting, W. Tony

    This report describes the various energy education programs and projects with which the Iowa Energy Policy Council has been involved since 1976. Briefly summarized are the Council's activities in curriculum development, inservice education, energy extension, and the organization of energy-related special events. (WB)

  12. Changes in Microbial Energy Metabolism Measured by Nanocalorimetry during Growth Phase Transitions

    PubMed Central

    Robador, Alberto; LaRowe, Douglas E.; Finkel, Steven E.; Amend, Jan P.; Nealson, Kenneth H.

    2018-01-01

    Calorimetric measurements of the change in heat due to microbial metabolic activity convey information about the kinetics, as well as the thermodynamics, of all chemical reactions taking place in a cell. Calorimetric measurements of heat production made on bacterial cultures have recorded the energy yields of all co-occurring microbial metabolic reactions, but this is a complex, composite signal that is difficult to interpret. Here we show that nanocalorimetry can be used in combination with enumeration of viable cell counts, oxygen consumption rates, cellular protein content, and thermodynamic calculations to assess catabolic rates of an isolate of Shewanella oneidensis MR-1 and infer what fraction of the chemical energy is assimilated by the culture into biomass and what fraction is dissipated in the form of heat under different limiting conditions. In particular, our results demonstrate that catabolic rates are not necessarily coupled to rates of cell division, but rather, to physiological rearrangements of S. oneidensis MR-1 upon growth phase transitions. In addition, we conclude that the heat released by growing microorganisms can be measured in order to understand the physiochemical nature of the energy transformation and dissipation associated with microbial metabolic activity in conditions approaching those found in natural systems. PMID:29449836

  13. Photosynthetic dioxygen formation studied by time-resolved delayed fluorescence measurements--method, rationale, and results on the activation energy of dioxygen formation.

    PubMed

    Buchta, Joachim; Grabolle, Markus; Dau, Holger

    2007-06-01

    The analysis of the time-resolved delayed fluorescence (DF) measurements represents an important tool to study quantitatively light-induced electron transfer as well as associated processes, e.g. proton movements, at the donor side of photosystem II (PSII). This method can provide, inter alia, insights in the functionally important inner-protein proton movements, which are hardly detectable by conventional spectroscopic approaches. The underlying rationale and experimental details of the method are described. The delayed emission of chlorophyll fluorescence of highly active PSII membrane particles was measured in the time domain from 10 mus to 60 ms after each flash of a train of nanosecond laser pulses. Focusing on the oxygen-formation step induced by the third flash, we find that the recently reported formation of an S4-intermediate prior to the onset of O-O bond formation [M. Haumann, P. Liebisch, C. Müller, M. Barra, M. Grabolle, H. Dau, Science 310, 1019-1021, 2006] is a multiphasic process, as anticipated for proton movements from the manganese complex of PSII to the aqueous bulk phase. The S4-formation involves three or more likely sequential steps; a tri-exponential fit yields time constants of 14, 65, and 200 mus (at 20 degrees C, pH 6.4). We determine that S4-formation is characterized by a sizable difference in Gibbs free energy of more than 90 meV (20 degrees C, pH 6.4). In the second part of the study, the temperature dependence (-2.7 to 27.5 degrees C) of the rate constant of dioxygen formation (600/s at 20 degrees C) was investigated by analysis of DF transients. If the activation energy is assumed to be temperature-independent, a value of 230 meV is determined. There are weak indications for a biphasicity in the Arrhenius plot, but clear-cut evidence for a temperature-dependent switch between two activation energies, which would point to the existence of two distinct rate-limiting steps, is not obtained.

  14. Physical Activity in Vietnam: Estimates and Measurement Issues.

    PubMed

    Bui, Tan Van; Blizzard, Christopher Leigh; Luong, Khue Ngoc; Truong, Ngoc Le Van; Tran, Bao Quoc; Otahal, Petr; Srikanth, Velandai; Nelson, Mark Raymond; Au, Thuy Bich; Ha, Son Thai; Phung, Hai Ngoc; Tran, Mai Hoang; Callisaya, Michele; Gall, Seana

    2015-01-01

    Our aims were to provide the first national estimates of physical activity (PA) for Vietnam, and to investigate issues affecting their accuracy. Measurements were made using the Global Physical Activity Questionnaire (GPAQ) on a nationally-representative sample of 14706 participants (46.5% males, response 64.1%) aged 25-64 years selected by multi-stage stratified cluster sampling. Approximately 20% of Vietnamese people had no measureable PA during a typical week, but 72.9% (men) and 69.1% (women) met WHO recommendations for PA by adults for their age. On average, 52.0 (men) and 28.0 (women) Metabolic Equivalent Task (MET)-hours/week (largely from work activities) were reported. Work and total PA were higher in rural areas and varied by season. Less than 2% of respondents provided incomplete information, but an additional one-in-six provided unrealistically high values of PA. Those responsible for reporting errors included persons from rural areas and all those with unstable work patterns. Box-Cox transformation (with an appropriate constant added) was the most successful method of reducing the influence of large values, but energy-scaled values were most strongly associated with pathophysiological outcomes. Around seven-in-ten Vietnamese people aged 25-64 years met WHO recommendations for total PA, which was mainly from work activities and higher in rural areas. Nearly all respondents were able to report their activity using the GPAQ, but with some exaggerated values and seasonal variation in reporting. Data transformation provided plausible summary values, but energy-scaling fared best in association analyses.

  15. Physical Activity in Vietnam: Estimates and Measurement Issues

    PubMed Central

    Bui, Tan Van; Blizzard, Christopher Leigh; Luong, Khue Ngoc; Truong, Ngoc Le Van; Tran, Bao Quoc; Otahal, Petr; Srikanth, Velandai; Nelson, Mark Raymond; Au, Thuy Bich; Ha, Son Thai; Phung, Hai Ngoc; Tran, Mai Hoang; Callisaya, Michele; Gall, Seana

    2015-01-01

    Introduction Our aims were to provide the first national estimates of physical activity (PA) for Vietnam, and to investigate issues affecting their accuracy. Methods Measurements were made using the Global Physical Activity Questionnaire (GPAQ) on a nationally-representative sample of 14706 participants (46.5% males, response 64.1%) aged 25−64 years selected by multi-stage stratified cluster sampling. Results Approximately 20% of Vietnamese people had no measureable PA during a typical week, but 72.9% (men) and 69.1% (women) met WHO recommendations for PA by adults for their age. On average, 52.0 (men) and 28.0 (women) Metabolic Equivalent Task (MET)-hours/week (largely from work activities) were reported. Work and total PA were higher in rural areas and varied by season. Less than 2% of respondents provided incomplete information, but an additional one-in-six provided unrealistically high values of PA. Those responsible for reporting errors included persons from rural areas and all those with unstable work patterns. Box-Cox transformation (with an appropriate constant added) was the most successful method of reducing the influence of large values, but energy-scaled values were most strongly associated with pathophysiological outcomes. Conclusions Around seven-in-ten Vietnamese people aged 25–64 years met WHO recommendations for total PA, which was mainly from work activities and higher in rural areas. Nearly all respondents were able to report their activity using the GPAQ, but with some exaggerated values and seasonal variation in reporting. Data transformation provided plausible summary values, but energy-scaling fared best in association analyses. PMID:26485044

  16. 10 CFR 436.104 - Energy conservation measures and standards.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Energy conservation measures and standards. 436.104 Section 436.104 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION FEDERAL ENERGY MANAGEMENT AND PLANNING PROGRAMS Guidelines for General Operations Plans § 436.104 Energy conservation measures and standards. (a...

  17. 10 CFR 436.104 - Energy conservation measures and standards.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Energy conservation measures and standards. 436.104 Section 436.104 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION FEDERAL ENERGY MANAGEMENT AND PLANNING PROGRAMS Guidelines for General Operations Plans § 436.104 Energy conservation measures and standards. (a...

  18. 10 CFR 436.104 - Energy conservation measures and standards.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Energy conservation measures and standards. 436.104 Section 436.104 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION FEDERAL ENERGY MANAGEMENT AND PLANNING PROGRAMS Guidelines for General Operations Plans § 436.104 Energy conservation measures and standards. (a...

  19. 10 CFR 436.104 - Energy conservation measures and standards.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Energy conservation measures and standards. 436.104 Section 436.104 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION FEDERAL ENERGY MANAGEMENT AND PLANNING PROGRAMS Guidelines for General Operations Plans § 436.104 Energy conservation measures and standards. (a...

  20. 10 CFR 436.104 - Energy conservation measures and standards.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Energy conservation measures and standards. 436.104 Section 436.104 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION FEDERAL ENERGY MANAGEMENT AND PLANNING PROGRAMS Guidelines for General Operations Plans § 436.104 Energy conservation measures and standards. (a...

  1. Activity and energy expenditure in older people playing active video games.

    PubMed

    Taylor, Lynne M; Maddison, Ralph; Pfaeffli, Leila A; Rawstorn, Jonathan C; Gant, Nicholas; Kerse, Ngaire M

    2012-12-01

    Tayl To quantify energy expenditure in older adults playing interactive video games while standing and seated, and secondarily to determine whether participants' balance status influenced the energy cost associated with active video game play. Cross-sectional study. University research center. Community-dwelling adults (N=19) aged 70.7±6.4 years. Participants played 9 active video games, each for 5 minutes, in random order. Two games (boxing and bowling) were played in both seated and standing positions. Energy expenditure was assessed using indirect calorimetry while at rest and during game play. Energy expenditure was expressed in kilojoules per minute and metabolic equivalents (METs). Balance was assessed using the mini-BESTest, the Activities-specific Balance Confidence Scale, and the Timed Up and Go (TUG). Mean ± SD energy expenditure was significantly greater for all game conditions compared with rest (all P≤.01) and ranged from 1.46±.41 METs to 2.97±1.16 METs. There was no significant difference in energy expenditure, activity counts, or perceived exertion between equivalent games played while standing and seated. No significant correlations were observed between energy expenditure or activity counts and balance status. Active video games provide light-intensity exercise in community-dwelling older people, whether played while seated or standing. People who are unable to stand may derive equivalent benefits from active video games played while seated. Further research is required to determine whether sustained use of active video games alters physical activity levels in community settings for this population. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  2. Government: Its Energy Policy and Activities.

    ERIC Educational Resources Information Center

    Winek, Gary J.

    1980-01-01

    Discusses the federal government's progress toward the formation of a national energy policy and briefly describes the energy activities of government agencies, especially the Department of Energy. (SK)

  3. Active interrogation using low-energy nuclear reactions

    NASA Astrophysics Data System (ADS)

    Antolak, Arlyn; Doyle, Barney; Leung, Ka-Ngo; Morse, Daniel; Provencio, Paula

    2005-09-01

    High-energy photons and neutrons can be used to interrogate for heavily shielded fissile materials inside sealed cargo containers by detecting their prompt and/or delayed fission signatures. The FIND (Fissmat Inspection for Nuclear Detection) active interrogation system is based on a dual neutron+gamma source that uses low-energy (< 500 keV) proton- or deuteron-induced nuclear reactions to produce high intensities of mono-energetic gamma rays and/or neutrons. The source can be operated in either pulsed (e.g., to detect delayed photofission neutrons and gammas) or continuous (e.g., detecting prompt fission signatures) modes. For the gamma-rays, the source target can be segmented to incorporate different (p,γ) isotopes for producing gamma-rays at selective energies, thereby improving the probability of detection. The design parameters for the FIND system are discussed and preliminary accelerator-based measurements of gamma and neutron yields, background levels, and fission signals for several target materials under consideration are presented.

  4. Electro-optic measurement of terahertz pulse energy distribution.

    PubMed

    Sun, J H; Gallacher, J G; Brussaard, G J H; Lemos, N; Issac, R; Huang, Z X; Dias, J M; Jaroszynski, D A

    2009-11-01

    An accurate and direct measurement of the energy distribution of a low repetition rate terahertz electromagnetic pulse is challenging because of the lack of sensitive detectors in this spectral range. In this paper, we show how the total energy and energy density distribution of a terahertz electromagnetic pulse can be determined by directly measuring the absolute electric field amplitude and beam energy density distribution using electro-optic detection. This method has potential use as a routine method of measuring the energy density of terahertz pulses that could be applied to evaluating future high power terahertz sources, terahertz imaging, and spatially and temporarily resolved pump-probe experiments.

  5. Tracking Photospheric Energy Transport in Active Regions with SDO

    NASA Astrophysics Data System (ADS)

    Attié, R.; Thompson, B. J.

    2017-12-01

    The solar photosphere presents flow fields at all observable scales. Where energy-bearing magnetic active regions break through the photosphere these flows are particularly strong, as sheared and twisted magnetic fields come into equilibrium with their surroundings while transporting magnetic energy into the corona. A part of this magnetic energy - the so-called `free energy' stored in the magnetic field in the form of "twisted" and shear of the field - is released in flares and eruptions. We can quantify the energy arrival and build-up in the corona by tracking flow fields and magnetic features at the photosphere as magnetic flux emerges and evolves before and after a flare or eruption.To do this reliably requires two things: a long series of photospheric observations at high sensitivity, spatial and temporal resolution, and an efficient, reliable and robust framework that tracks the photospheric plasma flows and magnetic evolution in both the quiet sun and active regions. SDO/HMI provides the observations, and we present here an innovative high resolution tracking framework that involves the `Balltracking' and `Magnetic Balltracking' algorithms. We show the first results of a systematic, quantitative and comprehensive measurements of the flows and transport of magnetic energy into the solar atmosphere and investigate whether this dynamic view can improve predictions of flares and Coronal Mass Ejections (CMEs).

  6. Density functional calculation of activation energies for lattice and grain boundary diffusion in alumina

    NASA Astrophysics Data System (ADS)

    Lei, Yinkai; Gong, Yu; Duan, Zhiyao; Wang, Guofeng

    2013-06-01

    To acquire knowledge on the lattice and grain boundary diffusion processes in alumina, we have determined the activation energies of elementary O and Al diffusive jumps in the bulk crystal, Σ3(0001) grain boundaries, and Σ3(101¯0) grain boundaries of α-Al2O3 using the first-principles density functional theory method. Specifically, we calculated the activation energies for four elementary jumps of both O and Al lattice diffusion in alumina. It was predicted that the activation energy of O lattice diffusion varied from 3.58 to 5.03 eV, while the activation energy of Al lattice diffusion ranged from 1.80 to 3.17 eV. As compared with experimental measurements, the theoretical predictions of the activation energy for lattice diffusion were lower and thus implied that there might be other high-energy diffusive jumps in the experimental alumina samples. Moreover, our results suggested that the Al lattice diffusion was faster than the O lattice diffusion in alumina, in agreement with experiment observations. Furthermore, it was found from our calculations for α-Al2O3 that the activation energies of O and Al grain boundary diffusion in the high-energy Σ3(0001) grain boundaries were significantly lower than those of the lattice diffusion. In contrast, the activation energies of O and Al grain boundary diffusion in the low-energy Σ3(101¯0) grain boundaries could be even higher than those of the lattice diffusion.

  7. Energy expenditure and activity of transfemoral amputees using mechanical and microprocessor-controlled prosthetic knees.

    PubMed

    Kaufman, Kenton R; Levine, James A; Brey, Robert H; McCrady, Shelly K; Padgett, Denny J; Joyner, Michael J

    2008-07-01

    To quantify the energy efficiency of locomotion and free-living physical activity energy expenditure of transfemoral amputees using a mechanical and microprocessor-controlled prosthetic knee. Repeated-measures design to evaluate comparative functional outcomes. Exercise physiology laboratory and community free-living environment. Subjects (N=15; 12 men, 3 women; age, 42+/-9 y; range, 26-57 y) with transfemoral amputation. Research participants were long-term users of a mechanical prosthesis (20+/-10 y as an amputee; range, 3-36 y). They were fitted with a microprocessor-controlled knee prosthesis and allowed to acclimate (mean time, 18+/-8 wk) before being retested. Objective measurements of energy efficiency and total daily energy expenditure were obtained. The Prosthetic Evaluation Questionnaire was used to gather subjective feedback from the participants. Subjects demonstrated significantly increased physical activity-related energy expenditure levels in the participant's free-living environment (P=.04) after wearing the microprocessor-controlled prosthetic knee joint. There was no significant difference in the energy efficiency of walking (P=.34). When using the microprocessor-controlled knee, the subjects expressed increased satisfaction in their daily lives (P=.02). People ambulating with a microprocessor-controlled knee significantly increased their physical activity during daily life, outside the laboratory setting, and expressed an increased quality of life.

  8. Quantitatively accurate activity measurements with a dedicated cardiac SPECT camera: Physical phantom experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pourmoghaddas, Amir, E-mail: apour@ottawaheart.ca; Wells, R. Glenn

    Purpose: Recently, there has been increased interest in dedicated cardiac single photon emission computed tomography (SPECT) scanners with pinhole collimation and improved detector technology due to their improved count sensitivity and resolution over traditional parallel-hole cameras. With traditional cameras, energy-based approaches are often used in the clinic for scatter compensation because they are fast and easily implemented. Some of the cardiac cameras use cadmium-zinc-telluride (CZT) detectors which can complicate the use of energy-based scatter correction (SC) due to the low-energy tail—an increased number of unscattered photons detected with reduced energy. Modified energy-based scatter correction methods can be implemented, but theirmore » level of accuracy is unclear. In this study, the authors validated by physical phantom experiments the quantitative accuracy and reproducibility of easily implemented correction techniques applied to {sup 99m}Tc myocardial imaging with a CZT-detector-based gamma camera with multiple heads, each with a single-pinhole collimator. Methods: Activity in the cardiac compartment of an Anthropomorphic Torso phantom (Data Spectrum Corporation) was measured through 15 {sup 99m}Tc-SPECT acquisitions. The ratio of activity concentrations in organ compartments resembled a clinical {sup 99m}Tc-sestamibi scan and was kept consistent across all experiments (1.2:1 heart to liver and 1.5:1 heart to lung). Two background activity levels were considered: no activity (cold) and an activity concentration 1/10th of the heart (hot). A plastic “lesion” was placed inside of the septal wall of the myocardial insert to simulate the presence of a region without tracer uptake and contrast in this lesion was calculated for all images. The true net activity in each compartment was measured with a dose calibrator (CRC-25R, Capintec, Inc.). A 10 min SPECT image was acquired using a dedicated cardiac camera with CZT detectors (Discovery NM530c

  9. Energy Expenditure and Intensity of Active Video Games in Children and Adolescents

    ERIC Educational Resources Information Center

    Canabrava, Karina L. R.; Faria, Fernanda R.; de Lima, Jorge R. P.; Guedes, Dartagnan P.; Amorim, Paulo R. S.

    2018-01-01

    Purpose: This study aimed to compare the energy expenditure and intensity of active video games to that of treadmill walking in children and adolescents. Method: Seventy-two boys and girls (aged 8-13 years) were recruited from local public schools. Energy expenditure and heart rate were measured during rest, during 3-km/hr, 4-km/hr, and 5-km/hr…

  10. Activation measurement of the 3He(alpha,gamma)7Be cross section at low energy.

    PubMed

    Bemmerer, D; Confortola, F; Costantini, H; Formicola, A; Gyürky, Gy; Bonetti, R; Broggini, C; Corvisiero, P; Elekes, Z; Fülöp, Zs; Gervino, G; Guglielmetti, A; Gustavino, C; Imbriani, G; Junker, M; Laubenstein, M; Lemut, A; Limata, B; Lozza, V; Marta, M; Menegazzo, R; Prati, P; Roca, V; Rolfs, C; Alvarez, C Rossi; Somorjai, E; Straniero, O; Strieder, F; Terrasi, F; Trautvetter, H P

    2006-09-22

    The nuclear physics input from the 3He(alpha,gamma)7Be cross section is a major uncertainty in the fluxes of 7Be and 8B neutrinos from the Sun predicted by solar models and in the 7Li abundance obtained in big-bang nucleosynthesis calculations. The present work reports on a new precision experiment using the activation technique at energies directly relevant to big-bang nucleosynthesis. Previously such low energies had been reached experimentally only by the prompt-gamma technique and with inferior precision. Using a windowless gas target, high beam intensity, and low background gamma-counting facilities, the 3He(alpha,gamma)7Be cross section has been determined at 127, 148, and 169 keV center-of-mass energy with a total uncertainty of 4%. The sources of systematic uncertainty are discussed in detail. The present data can be used in big-bang nucleosynthesis calculations and to constrain the extrapolation of the 3He(alpha,gamma)7Be astrophysical S factor to solar energies.

  11. Activities for Teaching Solar Energy.

    ERIC Educational Resources Information Center

    Mason, Jack Lee; Cantrell, Joseph S.

    1980-01-01

    Plans and activities are suggested for teaching elementary children about solar energy. Directions are included for constructing a flat plate collector and a solar oven. Activities for a solar field day are given. (SA)

  12. A simple method for electron energy constancy measurement

    PubMed Central

    King, R. Paul; Anderson, R. Scott

    2001-01-01

    A device is described for use in confirming the energy constancy of clinical electron beams. A wedge shaped absorber is placed over an ionization chamber leading to an energy dependent response. A measurement under the energy filter is divided by a measurement in air to correct for the inherent energy dependence of the chamber. A nearly linear response is demonstrated. PACS number(s): 87.52.–g, 87.53.–j, 87.66.–a PMID:11674838

  13. Thermodynamic Derivation of the Activation Energy for Ice Nucleation

    NASA Technical Reports Server (NTRS)

    Barahona, D.

    2015-01-01

    Cirrus clouds play a key role in the radiative and hydrological balance of the upper troposphere. Their correct representation in atmospheric models requires an understanding of the microscopic processes leading to ice nucleation. A key parameter in the theoretical description of ice nucleation is the activation energy, which controls the flux of water molecules from the bulk of the liquid to the solid during the early stages of ice formation. In most studies it is estimated by direct association with the bulk properties of water, typically viscosity and self-diffusivity. As the environment in the ice-liquid interface may differ from that of the bulk, this approach may introduce bias in calculated nucleation rates. In this work a theoretical model is proposed to describe the transfer of water molecules across the ice-liquid interface. Within this framework the activation energy naturally emerges from the combination of the energy required to break hydrogen bonds in the liquid, i.e., the bulk diffusion process, and the work dissipated from the molecular rearrangement of water molecules within the ice-liquid interface. The new expression is introduced into a generalized form of classical nucleation theory. Even though no nucleation rate measurements are used to fit any of the parameters of the theory the predicted nucleation rate is in good agreement with experimental results, even at temperature as low as 190 K, where it tends to be underestimated by most models. It is shown that the activation energy has a strong dependency on temperature and a weak dependency on water activity. Such dependencies are masked by thermodynamic effects at temperatures typical of homogeneous freezing of cloud droplets; however, they may affect the formation of ice in haze aerosol particles. The new model provides an independent estimation of the activation energy and the homogeneous ice nucleation rate, and it may help to improve the interpretation of experimental results and the

  14. Distributed activation energy model parameters of some Turkish coals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gunes, M.; Gunes, S.K.

    2008-07-01

    A multi-reaction model based on distributed activation energy has been applied to some Turkish coals. The kinetic parameters of distributed activation energy model were calculated via computer program developed for this purpose. It was observed that the values of mean of activation energy distribution vary between 218 and 248 kJ/mol, and the values of standard deviation of activation energy distribution vary between 32 and 70 kJ/mol. The correlations between kinetic parameters of the distributed activation energy model and certain properties of coal have been investigated.

  15. Energy expenditure and physical activity in Prader-Willi syndrome: comparison with obese subjects.

    PubMed

    Butler, Merlin G; Theodoro, Mariana F; Bittel, Douglas C; Donnelly, Joseph E

    2007-03-01

    Prader-Willi syndrome (PWS) is a complex neurodevelopmental disorder characterized by hypotonia, suck and feeding difficulties, hypogonadism, small hands and feet, developmental delay, hyperphagia and early childhood obesity and a particular facial appearance. The obesity associated with PWS is the result of a chronic imbalance between energy intake and energy expenditure (EE) due to hyperphagia, decreased physical activity, reduced metabolic rate and an inability to vomit. EE is affected by body composition as well as exercise. Individuals with PWS have a lower lean body mass (LBM) compared with controls which may contribute to reduced basal level EE. To determine the relationship among body composition, activity levels and metabolic rates, dual energy X-ray absorptiometry (DEXA) and a whole-room respiration chamber were used to measure body composition, total EE (TEE), resting EE (REE), physical activity, and mechanical work (MW) during an 8 hr monitoring period. The chamber consisted of a live-in whole-room indirect calorimeter equipped with a force platform floor to allow simultaneous measurement of EE, physical activity, and work efficiency during spontaneous activities and standardized exercise. Participants with PWS (27 with 15q11-q13 deletion and 21 with maternal disomy 15 with an average age of 23 years) had significantly decreased TEE by 20% and reduced LBM compared to 24 obese subjects. Similarly, REE was significantly reduced by 16% in the individuals with PWS relative to the comparison subjects. Total MW performed during the 8 hr monitoring period was significantly reduced by 35% in the PWS group. The energy cost of physical activity is related to the duration, intensity and type of activity and the metabolic efficiency of the individual. After adjusting group differences in LBM by analysis of variance, TEE and REE were no longer different between the two groups. Our data indicate that there is a significant reduction of EE in individuals with PWS

  16. Evaluation of the ability of three physical activity monitors to predict weight change and estimate energy expenditure.

    PubMed

    Correa, John B; Apolzan, John W; Shepard, Desti N; Heil, Daniel P; Rood, Jennifer C; Martin, Corby K

    2016-07-01

    Activity monitors such as the Actical accelerometer, the Sensewear armband, and the Intelligent Device for Energy Expenditure and Activity (IDEEA) are commonly validated against gold standards (e.g., doubly labeled water, or DLW) to determine whether they accurately measure total daily energy expenditure (TEE) or activity energy expenditure (AEE). However, little research has assessed whether these parameters or others (e.g., posture allocation) predict body weight change over time. The aims of this study were to (i) test whether estimated energy expenditure or posture allocation from the devices was associated with weight change during and following a low-calorie diet (LCD) and (ii) compare free-living TEE and AEE predictions from the devices against DLW before weight change. Eighty-seven participants from 2 clinical trials wore 2 of the 3 devices simultaneously for 1 week of a 2-week DLW period. Participants then completed an 8-week LCD and were weighed at the start and end of the LCD and 6 and 12 months after the LCD. More time spent walking at baseline, measured by the IDEEA, significantly predicted greater weight loss during the 8-week LCD. Measures of posture allocation demonstrated medium effect sizes in their relationships with weight change. Bland-Altman analyses indicated that the Sensewear and the IDEEA accurately estimated TEE, and the IDEEA accurately measured AEE. The results suggest that the ability of energy expenditure and posture allocation to predict weight change is limited, and the accuracy of TEE and AEE measurements varies across activity monitoring devices, with multi-sensor monitors demonstrating stronger validity.

  17. Evaluation of the ability of three physical activity monitors to predict weight change and estimate energy expenditure

    PubMed Central

    Correa, John B.; Apolzan, John W.; Shepard, Desti N.; Heil, Daniel P.; Rood, Jennifer C.; Martin, Corby K.

    2016-01-01

    Activity monitors such as the Actical accelerometer, the Sensewear armband, and the Intelligent Device for Energy Expenditure and Activity (IDEEA) are commonly validated against gold standards (e.g., doubly labeled water, or DLW) to determine whether they accurately measure total daily energy expenditure (TEE) or activity energy expenditure (AEE). However, little research has assessed whether these parameters or others (e.g., posture allocation) predict body weight change over time. The aims of this study were to (i) test whether estimated energy expenditure or posture allocation from the devices was associated with weight change during and following a low-calorie diet (LCD) and (ii) compare free-living TEE and AEE predictions from the devices against DLW before weight change. Eighty-seven participants from 2 clinical trials wore 2 of the 3 devices simultaneously for 1 week of a 2-week DLW period. Participants then completed an 8-week LCD and were weighed at the start and end of the LCD and 6 and 12 months after the LCD. More time spent walking at baseline, measured by the IDEEA, significantly predicted greater weight loss during the 8-week LCD. Measures of posture allocation demonstrated medium effect sizes in their relationships with weight change. Bland–Altman analyses indicated that the Sensewear and the IDEEA accurately estimated TEE, and the IDEEA accurately measured AEE. The results suggest that the ability of energy expenditure and posture allocation to predict weight change is limited, and the accuracy of TEE and AEE measurements varies across activity monitoring devices, with multi-sensor monitors demonstrating stronger validity. PMID:27270210

  18. Energy Expenditure and Activity of Transfemoral Amputees Using Mechanical and Microprocessor-Controlled Prosthetic Knees

    PubMed Central

    Kaufman, Kenton R.; Levine, James A.; Brey, Robert H.; McCrady, Shelly K.; Padgett, Denny J.; Joyner, Michael J.

    2009-01-01

    Objective To quantify the energy efficiency of locomotion and free-living physical activity energy expenditure of transfemoral amputees using a mechanical and microprocessor-controlled prosthetic knee. Design Repeated-measures design to evaluate comparative functional outcomes. Setting Exercise physiology laboratory and community free-living environment. Participants Subjects (N=15; 12 men, 3 women; age, 42±9y; range, 26 –57y) with transfemoral amputation. Intervention Research participants were long-term users of a mechanical prosthesis (20±10y as an amputee; range, 3–36y). They were fitted with a microprocessor-controlled knee prosthesis and allowed to acclimate (mean time, 18±8wk) before being retested. Main Outcome Measures Objective measurements of energy efficiency and total daily energy expenditure were obtained. The Prosthetic Evaluation Questionnaire was used to gather subjective feedback from the participants. Results Subjects demonstrated significantly increased physical activity–related energy expenditure levels in the participant’s free-living environment (P=.04) after wearing the microprocessor-controlled prosthetic knee joint. There was no significant difference in the energy efficiency of walking (P=.34). When using the microprocessor-controlled knee, the subjects expressed increased satisfaction in their daily lives (P=.02). Conclusions People ambulating with a microprocessor-controlled knee significantly increased their physical activity during daily life, outside the laboratory setting, and expressed an increased quality of life. PMID:18586142

  19. Energy and Man's Environment Activity Guide: An Interdisciplinary Teacher's Guide to Energy and Environmental Activities, Section One - Sources of Energy.

    ERIC Educational Resources Information Center

    Jones, John, Ed.

    This publication presents the activities pertaining to the first goal of this activity guide series. The activities in this publication focus primarily on the availability of resources, forms of energy, natural laws, and socioeconomic considerations. These materials are appropriate for middle school and junior high school students. These…

  20. Energy Activities for the Primary Classroom. Revised.

    ERIC Educational Resources Information Center

    Tierney, Blue, Comp.

    An energy education program at the primary level should help students to understand the nature and importance of energy, consider different energy sources, learn about energy conservation, prepare for energy related careers, and become energy conscious in other career fields. The activities charts, readings, and experiments provided in this…

  1. Validation of Web-Based Physical Activity Measurement Systems Using Doubly Labeled Water

    PubMed Central

    Yamaguchi, Yukio; Yamada, Yosuke; Tokushima, Satoru; Hatamoto, Yoichi; Sagayama, Hiroyuki; Kimura, Misaka; Higaki, Yasuki; Tanaka, Hiroaki

    2012-01-01

    Background Online or Web-based measurement systems have been proposed as convenient methods for collecting physical activity data. We developed two Web-based physical activity systems—the 24-hour Physical Activity Record Web (24hPAR WEB) and 7 days Recall Web (7daysRecall WEB). Objective To examine the validity of two Web-based physical activity measurement systems using the doubly labeled water (DLW) method. Methods We assessed the validity of the 24hPAR WEB and 7daysRecall WEB in 20 individuals, aged 25 to 61 years. The order of email distribution and subsequent completion of the two Web-based measurements systems was randomized. Each measurement tool was used for a week. The participants’ activity energy expenditure (AEE) and total energy expenditure (TEE) were assessed over each week using the DLW method and compared with the respective energy expenditures estimated using the Web-based systems. Results The mean AEE was 3.90 (SD 1.43) MJ estimated using the 24hPAR WEB and 3.67 (SD 1.48) MJ measured by the DLW method. The Pearson correlation for AEE between the two methods was r = .679 (P < .001). The Bland-Altman 95% limits of agreement ranged from –2.10 to 2.57 MJ between the two methods. The Pearson correlation for TEE between the two methods was r = .874 (P < .001). The mean AEE was 4.29 (SD 1.94) MJ using the 7daysRecall WEB and 3.80 (SD 1.36) MJ by the DLW method. The Pearson correlation for AEE between the two methods was r = .144 (P = .54). The Bland-Altman 95% limits of agreement ranged from –3.83 to 4.81 MJ between the two methods. The Pearson correlation for TEE between the two methods was r = .590 (P = .006). The average input times using terminal devices were 8 minutes and 10 seconds for the 24hPAR WEB and 6 minutes and 38 seconds for the 7daysRecall WEB. Conclusions Both Web-based systems were found to be effective methods for collecting physical activity data and are appropriate for use in epidemiological studies. Because the measurement

  2. Enhanced stochastic fluctuations to measure steep adhesive energy landscapes

    PubMed Central

    Haider, Ahmad; Potter, Daniel; Sulchek, Todd A.

    2016-01-01

    Free-energy landscapes govern the behavior of all interactions in the presence of thermal fluctuations in the fields of physical chemistry, materials sciences, and the biological sciences. From the energy landscape, critical information about an interaction, such as the reaction kinetic rates, bond lifetimes, and the presence of intermediate states, can be determined. Despite the importance of energy landscapes to understanding reaction mechanisms, most experiments do not directly measure energy landscapes, particularly for interactions with steep force gradients that lead to premature jump to contact of the probe and insufficient sampling of transition regions. Here we present an atomic force microscopy (AFM) approach for measuring energy landscapes that increases sampling of strongly adhesive interactions by using white-noise excitation to enhance the cantilever’s thermal fluctuations. The enhanced fluctuations enable the recording of subtle deviations from a harmonic potential to accurately reconstruct interfacial energy landscapes with steep gradients. Comparing the measured energy landscape with adhesive force measurements reveals the existence of an optimal excitation voltage that enables the cantilever fluctuations to fully sample the shape and depth of the energy surface. PMID:27911778

  3. Directed energy deflection laboratory measurements

    NASA Astrophysics Data System (ADS)

    Brashears, Travis; Lubin, Phillip; Hughes, Gary B.; Meinhold, Peter; Suen, Jonathan; Batliner, Payton; Motta, Caio; Griswold, Janelle; Kangas, Miikka; Johansson, Isbella; Alnawakhtha, Yusuf; Prater, Kenyon; Lang, Alex; Madajian, Jonathan

    2015-09-01

    We report on laboratory studies of the effectiveness of directed energy planetary defense as a part of the DESTAR (Directed Energy System for Targeting of Asteroids and exploRation) program. DE-STAR [1][5][6] and DE-STARLITE [2][5][6] are directed energy "stand-off" and "stand-on" programs, respectively. These systems consist of a modular array of kilowatt-class lasers powered by photovoltaics, and are capable of heating a spot on the surface of an asteroid to the point of vaporization. Mass ejection, as a plume of evaporated material, creates a reactionary thrust capable of diverting the asteroid's orbit. In a series of papers, we have developed a theoretical basis and described numerical simulations for determining the thrust produced by material evaporating from the surface of an asteroid [1][2][3][4][5][6]. In the DE-STAR concept, the asteroid itself is used as the deflection "propellant". This study presents results of experiments designed to measure the thrust created by evaporation from a laser directed energy spot. We constructed a vacuum chamber to simulate space conditions, and installed a torsion balance that holds an "asteroid" sample. The sample is illuminated with a fiber array laser with flux levels up to 60 MW/m2 which allows us to simulate a mission level flux but on a small scale. We use a separate laser as well as a position sensitive centroid detector to readout the angular motion of the torsion balance and can thus determine the thrust. We compare the measured thrust to the models. Our theoretical models indicate a coupling coefficient well in excess of 100 μN/Woptical, though we assume a more conservative value of 80 μN/Woptical and then degrade this with an optical "encircled energy" efficiency of 0.75 to 60 μN/Woptical in our deflection modeling. Our measurements discussed here yield about 45 μN/Wabsorbed as a reasonable lower limit to the thrust per optical watt absorbed.

  4. 78 FR 64414 - Assistance to Foreign Atomic Energy Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-29

    ... DEPARTMENT OF ENERGY 10 CFR Part 810 RIN 1994-AA02 Assistance to Foreign Atomic Energy Activities... Assistance to Foreign Atomic Energy Activities since 1986. The NOPR reflected a need to make the regulations... concerning Assistance to Foreign Atomic Energy Activities since 1986. (76 FR 55278) The NOPR reflected a need...

  5. A pediatric correlational study of stride interval dynamics, energy expenditure and activity level.

    PubMed

    Ellis, Denine; Sejdic, Ervin; Zabjek, Karl; Chau, Tom

    2014-08-01

    The strength of time-dependent correlations known as stride interval (SI) dynamics has been proposed as an indicator of neurologically healthy gait. Most recently, it has been hypothesized that these dynamics may be necessary for gait efficiency although the supporting evidence to date is scant. The current study examines over-ground SI dynamics, and their relationship with the cost of walking and physical activity levels in neurologically healthy children aged nine to 15 years. Twenty participants completed a single experimental session consisting of three phases: 10 min resting, 15 min walking and 10 min recovery. The scaling exponent (α) was used to characterize SI dynamics while net energy cost was measured using a portable metabolic cart, and physical activity levels were determined based on a 7-day recall questionnaire. No significant linear relationships were found between a and the net energy cost measures (r < .07; p > .25) or between α and physical activity levels (r = .01, p = .62). However, there was a marked reduction in the variance of α as activity levels increased. Over-ground stride dynamics do not appear to directly reflect energy conservation of gait in neurologically healthy youth. However, the reduction in the variance of α with increasing physical activity suggests a potential exercise-moderated convergence toward a level of stride interval persistence for able-bodied youth reported in the literature. This latter finding warrants further investigation.

  6. Improving energy efficiency via smart building energy management systems. A comparison with policy measures

    DOE PAGES

    Rocha, Paula; Siddiqui, Afzal; Stadler, Michael

    2014-12-09

    In this study, to foster the transition to more sustainable energy systems, policymakers have been approving measures to improve energy efficiency as well as promoting smart grids. In this setting, building managers are encouraged to adapt their energy operations to real-time market and weather conditions. Yet, most fail to do so as they rely on conventional building energy management systems (BEMS) that have static temperature set points for heating and cooling equipment. In this paper, we investigate how effective policy measures are at improving building-level energy efficiency compared to a smart BEMS with dynamic temperature set points. To this end,more » we present an integrated optimisation model mimicking the smart BEMS that combines decisions on heating and cooling systems operations with decisions on energy sourcing. Using data from an Austrian and a Spanish building, we find that the smart BEMS results in greater reduction in energy consumption than a conventional BEMS with policy measures.« less

  7. CMOS Active Pixel Sensors as energy-range detectors for proton Computed Tomography.

    PubMed

    Esposito, M; Anaxagoras, T; Evans, P M; Green, S; Manolopoulos, S; Nieto-Camero, J; Parker, D J; Poludniowski, G; Price, T; Waltham, C; Allinson, N M

    2015-06-03

    Since the first proof of concept in the early 70s, a number of technologies has been proposed to perform proton CT (pCT), as a means of mapping tissue stopping power for accurate treatment planning in proton therapy. Previous prototypes of energy-range detectors for pCT have been mainly based on the use of scintillator-based calorimeters, to measure proton residual energy after passing through the patient. However, such an approach is limited by the need for only a single proton passing through the energy-range detector in a read-out cycle. A novel approach to this problem could be the use of pixelated detectors, where the independent read-out of each pixel allows to measure simultaneously the residual energy of a number of protons in the same read-out cycle, facilitating a faster and more efficient pCT scan. This paper investigates the suitability of CMOS Active Pixel Sensors (APSs) to track individual protons as they go through a number of CMOS layers, forming an energy-range telescope. Measurements performed at the iThemba Laboratories will be presented and analysed in terms of correlation, to confirm capability of proton tracking for CMOS APSs.

  8. 10 CFR 455.102 - Energy conservation measure cost-share credit.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Energy conservation measure cost-share credit. 455.102 Section 455.102 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION GRANT PROGRAMS FOR SCHOOLS AND HOSPITALS... Energy conservation measure cost-share credit. To the extent a State provides in its State Plan, DOE may...

  9. 10 CFR 455.102 - Energy conservation measure cost-share credit.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Energy conservation measure cost-share credit. 455.102 Section 455.102 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION GRANT PROGRAMS FOR SCHOOLS AND HOSPITALS... Energy conservation measure cost-share credit. To the extent a State provides in its State Plan, DOE may...

  10. 10 CFR 455.102 - Energy conservation measure cost-share credit.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Energy conservation measure cost-share credit. 455.102 Section 455.102 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION GRANT PROGRAMS FOR SCHOOLS AND HOSPITALS... Energy conservation measure cost-share credit. To the extent a State provides in its State Plan, DOE may...

  11. Energy Adventure Center. Activity Book. Revised [and Expanded] Edition.

    ERIC Educational Resources Information Center

    Wichita Unified School District 259, KS.

    A variety of energy activities are provided, including instructions for and questions related to energy films. The activities are organized into five sections. Section 1 (work) includes an activity focusing on movement and change. Section 2 (forms of energy) includes activities related to mechanical (movement), radiant (light), chemical (burning),…

  12. Research and Construction of DC Energy Measurement Traceability Technology

    NASA Astrophysics Data System (ADS)

    Zhi, Wang; Maotao, Yang; Jing, Yang

    2018-02-01

    With the implementation of energy saving and emission reduction policies, DC energy metering has been widely used in many fields. In view of the lack of a DC energy measurementtraceability system, in combination with the process of downward measurement transfer in relation to the DC charger-based field calibration technology and DC energy meter and shunt calibration technologies, the paper proposed DC fast charging, high DC, small DC voltage output and measuring technologies, and built a time-based plan by converting high DC voltage into low voltage and high current into low current and then into low voltage, leaving DC energy traceable to national standards in terms of voltage, current and time and thus filling in the gap in DC energy measurement traceability.

  13. Nonadiabatic coupling reduces the activation energy in thermally activated delayed fluorescence.

    PubMed

    Gibson, J; Penfold, T J

    2017-03-22

    The temperature dependent rate of a thermally activated process is given by the Arrhenius equation. The exponential decrease in the rate with activation energy, which this imposes, strongly promotes processes with small activation barriers. This criterion is one of the most challenging during the design of thermally activated delayed fluorescence (TADF) emitters used in organic light emitting diodes. The small activation energy is usually achieved with donor-acceptor charge transfer complexes. However, this sacrifices the radiative rate and is therefore incommensurate with the high luminescence quantum yields required for applications. Herein we demonstrate that the spin-vibronic mechanism, operative for efficient TADF, overcomes this limitation. Nonadiabatic coupling between the lowest two triplet states give rise to a strong enhancement of the rate of reserve intersystem crossing via a second order mechanism and promotes population transfer between the T 1 to T 2 states. Consequently the rISC mechanism is actually operative between initial and final state exhibiting an energy gap that is smaller than between the T 1 and S 1 states. This contributes to the small activation energies for molecules exhibiting a large optical gap, identifies limitations of the present design procedures and provides a basis from which to construct TADF molecules with simultaneous high radiative and rISC rates.

  14. Measurements of Daily Energy Intake and Total Energy Expenditure in People with Dementia in Care Homes: The Use of Wearable Technology.

    PubMed

    Murphy, J; Holmes, J; Brooks, C

    2017-01-01

    To estimate daily total energy expenditure (TEE) using a physical activity monitor, combined with dietary assessment of energy intake to assess the relationship between daily energy expenditure and patterns of activity with energy intake in people with dementia living in care homes. A cross-sectional study in care homes in the UK. Twenty residents with confirmed dementia diagnosis were recruited from two care homes that specialised in dementia care. A physical activity monitor (SensewearTM Armband, Body Media, Pittsburgh, PA) was employed to objectively determine total energy expenditure, sleep duration and physical activity. The armband was placed around the left upper triceps for up to 7 days. Energy intake was determined by weighing all food and drink items over 4 days (3 weekdays and 1 weekend day) including measurements of food wastage. The mean age was 78.7 (SD ± 11.8) years, Body Mass Index (BMI) 23.0 (SD ± 4.2) kg/m2; 50% were women. Energy intake (mean 7.4; SD ± 2.6) MJ/d) was correlated with TEE (mean 7.6; SD ± 1.8 MJ/d; r=0.49, p<0.05). Duration of sleeping ranged from 0.4-12.5 (mean 6.1) hrs/d and time spent lying down was 1.3-16.0 (8.3) hrs/d. On average residents spent 17.9 (6.3-23.4) hrs/d undertaking sedentary activity. TEE was correlated with BMI (r=0.52, p<0.05) and body weight (r=0.81, p<0.001) but inversely related to sleep duration (r=-0.59, p<0.01) and time lying down (r=-0.62, p<0.01). Multiple linear regression analysis revealed that after taking BMI, sleep duration and time spent lying down into account, TEE was no longer correlated with energy intake. The results show the extent to which body mass, variable activity and sleep patterns may be contributing to TEE and together with reduced energy intake, energy requirements were not satisfied. Thus wearable technology has the potential to offer real-time monitoring to provide appropriate nutrition management that is more person-centred to prevent weight loss in dementia.

  15. Black hole firewalls require huge energy of measurement

    NASA Astrophysics Data System (ADS)

    Hotta, Masahiro; Matsumoto, Jiro; Funo, Ken

    2014-06-01

    The unitary moving mirror model is one of the best quantum systems for checking the reasoning of the original firewall paradox of Almheiri et al. [J. High Energy Phys. 02 (2013) 062] in quantum black holes. Though the late-time part of radiations emitted from the mirror is fully entangled with the early part, no firewall exists with a deadly, huge average energy flux in this model. This is because the high-energy entanglement structure of the discretized systems in almost maximally entangled states is modified so as to yield the correct description of low-energy effective field theory. Furthermore, the strong subadditivity paradox of firewalls is resolved using nonlocality of general one-particle states and zero-point fluctuation entanglement. Due to the Reeh-Schlieder theorem in quantum field theory, another firewall paradox is inevitably raised with quantum remote measurements in the model. We resolve this paradox from the viewpoint of the energy cost of measurements. No firewall appears, as long as the energy for the measurement is much smaller than the ultraviolet cutoff scale.

  16. [Sedentary lifestyle: physical activity duration versus percentage of energy expenditure].

    PubMed

    Cabrera de León, Antonio; Rodríguez-Pérez, María del C; Rodríguez-Benjumeda, Luis M; Anía-Lafuente, Basilio; Brito-Díaz, Buenaventura; Muros de Fuentes, Mercedes; Almeida-González, Delia; Batista-Medina, Marta; Aguirre-Jaime, Armando

    2007-03-01

    To compare different definitions of a sedentary lifestyle and to determine which is the most appropriate for demonstrating its relationship with the metabolic syndrome and other cardiovascular risk factors. A cross-sectional study of 5814 individuals was carried out. Comparisons were made between two definitions of a sedentary lifestyle: one based on active energy expenditure being less than 10% of total energy expenditure, and the other, on performing less than 25-30 minutes of physical activity per day. Reported levels of physical activity, anthropometric measurements, and biochemical markers of cardiovascular risk were recorded. The associations between a sedentary lifestyle and metabolic syndrome and other risk factors were adjusted for gender, age and tobacco use. The prevalence of a sedentary lifestyle was higher in women (70%) than in men (45-60%, according to the definition used). The definitions based on physical activity duration and on energy expenditure were equally useful: there were direct associations between a sedentary lifestyle and metabolic syndrome, body mass index, abdominal and pelvic circumferences, systolic blood pressure, heart rate, apolipoprotein B, and triglycerides, and inverse associations with high-density lipoprotein cholesterol and paraoxonase activity, which demonstrated the greatest percentage difference between sedentary and active individuals. An incidental finding was that both definitions of a sedentary lifestyle were more strongly associated with the metabolic syndrome as defined by International Diabetes Federation criteria than by Adult Treatment Panel III criteria. Given that it is relatively easy to determine whether a patient performs less than 25 minutes of physical activity per day, use of this definition of a sedentary lifestyle is recommended for clinical practice. The serum paraoxonase activity level could provide a useful marker for studying sedentary lifestyles.

  17. Genetic association between body energy measured throughout lactation and fertility in dairy cattle.

    PubMed

    Banos, G; Coffey, M P

    2010-02-01

    The objective of this study was to quantify the genetic association of body energy assessed throughout lactation with a cow's fertility. Nine direct and indirect body energy traits were defined at different stages of lactation. Four were daily records of energy balance, energy content, cumulative effective energy (CEE) and body condition score (BCS) calculated between lactation days 4 and 311. The other five traits included duration of negative energy balance (DNEB), rate of recovery during DNEB (RNEB), sum of negative energy balance (SNEB), nadir of energy content (NEC) and number of days from calving to NEC. Of these traits, energy balance, DNEB, RNEB and SNEB were primarily based on individual cow feed intake and milk yield, and considered direct measures of body energy. The other traits were calculated from body lipid and protein changes, predicted from BCS and live weight profiles, and were considered indirect measures of body energy. Fertility was defined by number of days between calving and commencement of luteal activity (DLA), first observed oestrus (DH) and conception (DC), and number of services per conception. A total of 957 cows in their first four lactations were considered in the study. Genetic models fitted cubic splines to define longitudinal traits (energy balance, energy content, CEE and BCS) and calculate heritability and genetic correlation with fertility. Daily heritability estimate ranges were 0.10 to 0.34, 0.35 to 0.61, 0.32 to 0.53 and 0.24 to 0.56 for energy balance, energy content, CEE and BCS, respectively, and, in most cases, tended to increase towards the middle of lactation and remain relatively stable thereafter. Of the other body energy traits, heritability of NEC (0.44) was the most notable. Statistically significant (P < 0.05) genetic correlations of DH with daily energy balance, energy content, CEE and BCS ranged from -0.16 to -0.28, -0.35 to -0.48, -0.16 to -0.26 and -0.37 to -0.44, respectively. For DC, respective estimates

  18. Microparticle impact sensor measures energy directly

    NASA Technical Reports Server (NTRS)

    Alexander, W. M.; Berg, O. E.

    1965-01-01

    Construction of a capacitor sensor consisting of a dielectric layer between two conductive surface layers and connected across a potential source through a sensing resistor permits measurement of energy of impinging particles without degradation of sensitivity. A measurable response is produced without penetration of the dielectric layer.

  19. Energy Savings Measure Packages. Existing Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Casey, Sean; Booten, Chuck

    2011-11-01

    This document presents the most cost effective Energy Savings Measure Packages (ESMP) for existing mixed-fuel and all electric homes to achieve 15% and 30% savings for each BetterBuildings grantee location across the United States. These packages are optimized for minimum cost to homeowners for source energy savings given the local climate and prevalent building characteristics (i.e. foundation types). Maximum cost savings are typically found between 30% and 50% energy savings over the reference home; this typically amounts to $300 - $700/year.

  20. Measurement of Daily Activity in Restrictive Type Anorexia Nervosa

    PubMed Central

    Harris, Ann M.; McAlpine, Donald E.; Shirbhate, Rashmi; Manohar, Chinmay U.; Levine, James A.

    2009-01-01

    Objective The assessment of daily activity in patients with restrictive type anorexia nervosa is limited by an absence of accurate and precise technology. We wanted to test a daily activity detecting device named, the Physical Activity Monitoring System (PAMS). Method Women participants with restrictive type anorexia nervosa (n = 8, 36 ± 11 years, 17 ± 2 kg/m2) and healthy women participants (n = 8, 30 ± 11 years, 27 ± 7 kg/m2) were asked to lie, sit and stand motionless, and walk at 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0 mph whilst wearing PAMS. Results For all restrictive type anorexia nervosa and healthy participants, body posture was correctly detected for all measurements (300/300). There was excellent correlation of an individual’s body acceleration with walking velocity and walking energy expenditure (r2> 0.99). Conclusions The PAMS technology could serve as a tool for lending insight into the pathophysiology of restrictive type anorexia nervosa; and potentially measuring compliance with activity recommendations for medical professionals treating individuals with restrictive type anorexia nervosa. PMID:18004719

  1. Measuring Intermolecular Binding Energies by Laser Spectroscopy.

    PubMed

    Knochenmuss, Richard; Maity, Surajit; Féraud, Géraldine; Leutwyler, Samuel

    2017-02-22

    The ground-state dissociation energy, D0(S0), of isolated intermolecular complexes in the gas phase is a fundamental measure of the interaction strength between the molecules. We have developed a three-laser, triply resonant pump-dump-probe technique to measure dissociation energies of jet-cooled M•S complexes, where M is an aromatic chromophore and S is a closed-shell 'solvent' molecule. Stimulated emission pumping (SEP) via the S0→S1 electronic transition is used to precisely 'warm' the complex by populating high vibrational levels v" of the S0 state. If the deposited energy E(v") is less than D0(S0), the complex remains intact, and is then mass- and isomer-selectively detected by resonant two-photon ionization (R2PI) with a third (probe) laser. If the pumped level is above D0(S0), the hot complex dissociates and the probe signal disappears. Combining the fluorescence or SEP spectrum of the cold complex with the SEP breakoff of the hot complex brackets D0(S0). The UV chromophores 1-naphthol and carbazole were employed; these bind either dispersively via the aromatic rings, or form a hydrogen bond via the -OH or -NH group. Dissociation energies have been measured for dispersively bound complexes with noble gases (Ne, Kr, Ar, Xe), diatomics (N2, CO), alkanes (methane to n-butane), cycloalkanes (cyclopropane to cycloheptane), and unsaturated compounds (ethene, benzene). Hydrogen-bond dissociation energies have been measured for H2O, D2O, methanol, ethanol, ethers (oxirane, oxetane), NH3 and ND3.

  2. Cellular Links between Neuronal Activity and Energy Homeostasis.

    PubMed

    Shetty, Pavan K; Galeffi, Francesca; Turner, Dennis A

    2012-01-01

    Neuronal activity, astrocytic responses to this activity, and energy homeostasis are linked together during baseline, conscious conditions, and short-term rapid activation (as occurs with sensory or motor function). Nervous system energy homeostasis also varies during long-term physiological conditions (i.e., development and aging) and with adaptation to pathological conditions, such as ischemia or low glucose. Neuronal activation requires increased metabolism (i.e., ATP generation) which leads initially to substrate depletion, induction of a variety of signals for enhanced astrocytic function, and increased local blood flow and substrate delivery. Energy generation (particularly in mitochondria) and use during ATP hydrolysis also lead to considerable heat generation. The local increases in blood flow noted following neuronal activation can both enhance local substrate delivery but also provides a heat sink to help cool the brain and removal of waste by-products. In this review we highlight the interactions between short-term neuronal activity and energy metabolism with an emphasis on signals and factors regulating astrocyte function and substrate supply.

  3. [Measurement of physical activity in older adults. Correlation between the PRISCUS-PAQ and accelerometry].

    PubMed

    Trampisch, U S; Platen, P; Moschny, A; Wilm, S; Thiem, U; Hinrichs, T

    2012-04-01

    The German questionnaire PRISCUS-PAQ was developed to measure actual physical activity of older adults in a telephone interview. PRISCUS-PAQ consists of ten main questions to assess the time spend in domestic activities (e.g., housework, gardening), sporting activities (e.g., riding a bicycle), and inactivity (e.g., sedentary activity, sleeping during the day) during the prior week. By assessing the number of days for each activity and the mean duration of performing this activity, a total score can be calculated. The total score corresponds to the energy consumption for 1 week. The aim of this study is to estimate the correlation of the PRISCUS-PAQ total score and accelerometry as an objective measurement method for the assessment of physical activity. A total of 114 participants (58% women) with a mean age of 76 years participated in the study. PRISCUS-PAQ was initially analyzed descriptively. To assess the validity of PRISCUS-PAQ, the correlation (correlation coefficient of Spearman) was calculated between the total score of the questionnaire PRISCUS-PAQ and the 95% trimmed sum of an accelerometer with a measurement period of 1 week. The correlation coefficient for the association of the PRISCUS-PAQ total score and the 95% trimmed sum of the acceleration values was r = 0.28 (95% confidence interval 0.10–0.44). Activities of daily life like cleaning and other domestic activities highly contributed to the weekly energy consumption of the participants. The association between the PRISCUS-PAQ questionnaire and accelerometry measured physical activity is comparable to other validated and established international questionnaires. The PRISCUS-PAQ is the first German questionnaire that allows the measurement of physical activity of older adults in a telephone interview.

  4. Assessment of laboratory and daily energy expenditure estimates from consumer multi-sensor physical activity monitors.

    PubMed

    Chowdhury, Enhad A; Western, Max J; Nightingale, Thomas E; Peacock, Oliver J; Thompson, Dylan

    2017-01-01

    Wearable physical activity monitors are growing in popularity and provide the opportunity for large numbers of the public to self-monitor physical activity behaviours. The latest generation of these devices feature multiple sensors, ostensibly similar or even superior to advanced research instruments. However, little is known about the accuracy of their energy expenditure estimates. Here, we assessed their performance against criterion measurements in both controlled laboratory conditions (simulated activities of daily living and structured exercise) and over a 24 hour period in free-living conditions. Thirty men (n = 15) and women (n = 15) wore three multi-sensor consumer monitors (Microsoft Band, Apple Watch and Fitbit Charge HR), an accelerometry-only device as a comparison (Jawbone UP24) and validated research-grade multi-sensor devices (BodyMedia Core and individually calibrated Actiheart™). During discrete laboratory activities when compared against indirect calorimetry, the Apple Watch performed similarly to criterion measures. The Fitbit Charge HR was less consistent at measurement of discrete activities, but produced similar free-living estimates to the Apple Watch. Both these devices underestimated free-living energy expenditure (-394 kcal/d and -405 kcal/d, respectively; P<0.01). The multi-sensor Microsoft Band and accelerometry-only Jawbone UP24 devices underestimated most laboratory activities and substantially underestimated free-living expenditure (-1128 kcal/d and -998 kcal/d, respectively; P<0.01). None of the consumer devices were deemed equivalent to the reference method for daily energy expenditure. For all devices, there was a tendency for negative bias with greater daily energy expenditure. No consumer monitors performed as well as the research-grade devices although in some (but not all) cases, estimates were close to criterion measurements. Thus, whilst industry-led innovation has improved the accuracy of consumer monitors, these devices

  5. Assessment of laboratory and daily energy expenditure estimates from consumer multi-sensor physical activity monitors

    PubMed Central

    Chowdhury, Enhad A.; Western, Max J.; Nightingale, Thomas E.; Peacock, Oliver J.; Thompson, Dylan

    2017-01-01

    Wearable physical activity monitors are growing in popularity and provide the opportunity for large numbers of the public to self-monitor physical activity behaviours. The latest generation of these devices feature multiple sensors, ostensibly similar or even superior to advanced research instruments. However, little is known about the accuracy of their energy expenditure estimates. Here, we assessed their performance against criterion measurements in both controlled laboratory conditions (simulated activities of daily living and structured exercise) and over a 24 hour period in free-living conditions. Thirty men (n = 15) and women (n = 15) wore three multi-sensor consumer monitors (Microsoft Band, Apple Watch and Fitbit Charge HR), an accelerometry-only device as a comparison (Jawbone UP24) and validated research-grade multi-sensor devices (BodyMedia Core and individually calibrated Actiheart™). During discrete laboratory activities when compared against indirect calorimetry, the Apple Watch performed similarly to criterion measures. The Fitbit Charge HR was less consistent at measurement of discrete activities, but produced similar free-living estimates to the Apple Watch. Both these devices underestimated free-living energy expenditure (-394 kcal/d and -405 kcal/d, respectively; P<0.01). The multi-sensor Microsoft Band and accelerometry-only Jawbone UP24 devices underestimated most laboratory activities and substantially underestimated free-living expenditure (-1128 kcal/d and -998 kcal/d, respectively; P<0.01). None of the consumer devices were deemed equivalent to the reference method for daily energy expenditure. For all devices, there was a tendency for negative bias with greater daily energy expenditure. No consumer monitors performed as well as the research-grade devices although in some (but not all) cases, estimates were close to criterion measurements. Thus, whilst industry-led innovation has improved the accuracy of consumer monitors, these devices

  6. Characterization of a Gafchromic film for the two-dimensional profile measurement of low-energy heavy-ion beams

    NASA Astrophysics Data System (ADS)

    Yuri, Yosuke; Narumi, Kazumasa; Yuyama, Takahiro

    2016-08-01

    The feasibility of the transverse intensity distribution measurement of low-energy (keV/u range) heavy-ion beams using radiochromic films is experimentally explored. We employ a Gafchromic radiochromic film, HD-V2, whose active layer is not laminated by a surface-protection layer. The coloration response of films irradiated with several ion beams is characterized in terms of optical density (OD) by reading the films with a general-purpose scanner. To explore the energy dependence of the film response widely, the kinetic energy of the beams is varied from 1.5 keV/u to 27 MeV/u. We have found that the coloration of HD-V2 films is induced by irradiation with low-energy ion beams of the order of 10 keV/u. The range of the beams is considerably shorter than the thickness of the film's active layer. The dependence of OD response on ion species is also discussed. We demonstrate that the Gafchromic film used here is useful for measuring the intensity distribution of such low-energy ion beams.

  7. A Comparison of Energy Expenditure Estimation of Several Physical Activity Monitors

    PubMed Central

    Dannecker, Kathryn L.; Sazonova, Nadezhda A.; Melanson, Edward L.; Sazonov, Edward S.; Browning, Raymond C.

    2013-01-01

    Accurately and precisely estimating free-living energy expenditure (EE) is important for monitoring energy balance and quantifying physical activity. Recently, single and multi-sensor devices have been developed that can classify physical activities, potentially resulting in improved estimates of EE. PURPOSE To determine the validity of EE estimation of a footwear-based physical activity monitor and to compare this validity against a variety of research and consumer physical activity monitors. METHODS Nineteen healthy young adults (10 male, 9 female), completed a four-hour stay in a room calorimeter. Participants wore a footwear-based physical activity monitor, as well as Actical, Actigraph, IDEEA, DirectLife and Fitbit devices. Each individual performed a series of postures/activities. We developed models to estimate EE from the footwear-based device, and we used the manufacturer's software to estimate EE for all other devices. RESULTS Estimated EE using the shoe-based device was not significantly different than measured EE (476(20) vs. 478(18) kcal) (Mean (SE)), respectively, and had a root mean square error (RMSE) of (29.6 kcal (6.2%)). The IDEEA and DirectLlife estimates of EE were not significantly different than the measured EE but the Actigraph and Fitbit devices significantly underestimated EE. Root mean square errors were 93.5 (19%), 62.1 kcal (14%), 88.2 kcal (18%), 136.6 kcal (27%), 130.1 kcal (26%), and 143.2 kcal (28%) for Actical, DirectLife, IDEEA, Actigraph and Fitbit respectively. CONCLUSIONS The shoe based physical activity monitor provides a valid estimate of EE while the other physical activity monitors tested have a wide range of validity when estimating EE. Our results also demonstrate that estimating EE based on classification of physical activities can be more accurate and precise than estimating EE based on total physical activity. PMID:23669877

  8. A comparison of energy expenditure estimation of several physical activity monitors.

    PubMed

    Dannecker, Kathryn L; Sazonova, Nadezhda A; Melanson, Edward L; Sazonov, Edward S; Browning, Raymond C

    2013-11-01

    Accurately and precisely estimating free-living energy expenditure (EE) is important for monitoring energy balance and quantifying physical activity. Recently, single and multisensor devices have been developed that can classify physical activities, potentially resulting in improved estimates of EE. This study aimed to determine the validity of EE estimation of a footwear-based physical activity monitor and to compare this validity against a variety of research and consumer physical activity monitors. Nineteen healthy young adults (10 men, 9 women) completed a 4-h stay in a room calorimeter. Participants wore a footwear-based physical activity monitor as well as Actical, ActiGraph, IDEEA, DirectLife, and Fitbit devices. Each individual performed a series of postures/activities. We developed models to estimate EE from the footwear-based device, and we used the manufacturer's software to estimate EE for all other devices. Estimated EE using the shoe-based device was not significantly different than measured EE (mean ± SE; 476 ± 20 vs 478 ± 18 kcal, respectively) and had a root-mean-square error of 29.6 kcal (6.2%). The IDEEA and the DirectLlife estimates of EE were not significantly different than the measured EE, but the ActiGraph and the Fitbit devices significantly underestimated EE. Root-mean-square errors were 93.5 (19%), 62.1 kcal (14%), 88.2 kcal (18%), 136.6 kcal (27%), 130.1 kcal (26%), and 143.2 kcal (28%) for Actical, DirectLife, IDEEA, ActiGraph, and Fitbit, respectively. The shoe-based physical activity monitor provides a valid estimate of EE, whereas the other physical activity monitors tested have a wide range of validity when estimating EE. Our results also demonstrate that estimating EE based on classification of physical activities can be more accurate and precise than estimating EE based on total physical activity.

  9. The energy expenditure of an activity-promoting video game compared to sedentary video games and TV watching.

    PubMed

    Mitre, Naim; Foster, Randal C; Lanningham-Foster, Lorraine; Levine, James A

    2011-01-01

    In the present study we investigated the effect of television watching and the use of activity-promoting video games on energy expenditure in obese and lean children. Energy expenditure and physical activity were measured while participants were watching television, playing a video game on a traditional sedentary video game console, and while playing the same video game on an activity-promoting video game console. Energy expenditure was significantly greater than television watching and playing video games on a sedentary video game console when children played the video game on the activity-promoting console. When examining movement with accelerometry, children moved significantly more when playing the video game on the Nintendo Wii console. Activity-promoting video games have shown to increase movement, and be an important tool to raise energy expenditure by 50% when compared to sedentary activities of daily living.

  10. Environmental Measurements Laboratory fiscal year 1998: Accomplishments and technical activities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erickson, M.D.

    1999-01-01

    The Environmental Measurements Laboratory (EML) is government-owned, government-operated, and programmatically under the DOE Office of Environmental Management. The Laboratory is administered by the Chicago Operations Office. EML provides program management, technical assistance and data quality assurance for measurements of radiation and radioactivity relating to environmental restoration, global nuclear nonproliferation, and other priority issues for the Department of Energy, as well as for other government, national, and international organizations. This report presents the technical activities and accomplishments of EML for Fiscal Year 1998.

  11. Energy Conservation Activities for the Classroom K-12.

    ERIC Educational Resources Information Center

    Kentucky Dept. of Energy, Frankfort.

    After a brief introduction entitled "Where Does the Energy We Use Come From," this unit presents 86 activities. Each activity gives the title, concept, objectives, subject area, level, time involved, materials needed, procedures, and related career activities. Topics cover everything from housing insulation to alternate sources of energy to energy…

  12. MAGNETIC ENERGY SPECTRA IN SOLAR ACTIVE REGIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abramenko, Valentyna; Yurchyshyn, Vasyl

    Line-of-sight magnetograms for 217 active regions (ARs) with different flare rates observed at the solar disk center from 1997 January until 2006 December are utilized to study the turbulence regime and its relationship to flare productivity. Data from the SOHO/MDI instrument recorded in the high-resolution mode and data from the BBSO magnetograph were used. The turbulence regime was probed via magnetic energy spectra and magnetic dissipation spectra. We found steeper energy spectra for ARs with higher flare productivity. We also report that both the power index, {alpha}, of the energy spectrum, E(k) {approx} k{sup -}{alpha}, and the total spectral energy,more » W = {integral}E(k)dk, are comparably correlated with the flare index, A, of an AR. The correlations are found to be stronger than those found between the flare index and the total unsigned flux. The flare index for an AR can be estimated based on measurements of {alpha} and W as A = 10{sup b}({alpha}W){sup c}, with b = -7.92 {+-} 0.58 and c = 1.85 {+-} 0.13. We found that the regime of the fully developed turbulence occurs in decaying ARs and in emerging ARs (at the very early stage of emergence). Well-developed ARs display underdeveloped turbulence with strong magnetic dissipation at all scales.« less

  13. Negative vacuum energy densities and the causal diamond measure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salem, Michael P.

    2009-07-15

    Arguably a major success of the landscape picture is the prediction of a small, nonzero vacuum energy density. The details of this prediction depend in part on how the diverging spacetime volume of the multiverse is regulated, a question that remains unresolved. One proposal, the causal diamond measure, has demonstrated many phenomenological successes, including predicting a distribution of positive vacuum energy densities in good agreement with observation. In the string landscape, however, the vacuum energy density is expected to take positive and negative values. We find the causal diamond measure gives a poor fit to observation in such a landscapemore » - in particular, 99.6% of observers in galaxies seemingly just like ours measure a vacuum energy density smaller than we do, most of them measuring it to be negative.« less

  14. Activation energy and energy density: a bioenergetic framework for assessing soil organic matter stability

    NASA Astrophysics Data System (ADS)

    Williams, E. K.; Plante, A. F.

    2017-12-01

    The stability and cycling of natural organic matter depends on the input of energy needed to decompose it and the net energy gained from its decomposition. In soils, this relationship is complicated by microbial enzymatic activity which decreases the activation energies associated with soil organic matter (SOM) decomposition and by chemical and physical protection mechanisms which decreases the concentrations of the available organic matter substrate and also require additional energies to overcome for decomposition. In this study, we utilize differential scanning calorimetry and evolved CO2 gas analysis to characterize differences in the energetics (activation energy and energy density) in soils that have undergone degradation in natural (bare fallow), field (changes in land-use), chemical (acid hydrolysis), and laboratory (high temperature incubation) experimental conditions. We will present this data in a novel conceptual framework relating these energy dynamics to organic matter inputs, decomposition, and molecular complexity.

  15. Direct Measurement of the Surface Energy of Graphene.

    PubMed

    van Engers, Christian D; Cousens, Nico E A; Babenko, Vitaliy; Britton, Jude; Zappone, Bruno; Grobert, Nicole; Perkin, Susan

    2017-06-14

    Graphene produced by chemical vapor deposition (CVD) is a promising candidate for implementing graphene in a range of technologies. In most device configurations, one side of the graphene is supported by a solid substrate, wheras the other side is in contact with a medium of interest, such as a liquid or other two-dimensional material within a van der Waals stack. In such devices, graphene interacts on both faces via noncovalent interactions and therefore surface energies are key parameters for device fabrication and operation. In this work, we directly measured adhesive forces and surface energies of CVD-grown graphene in dry nitrogen, water, and sodium cholate using a modified surface force balance. For this, we fabricated large (∼1 cm 2 ) and clean graphene-coated surfaces with smooth topography at both macro- and nanoscales. By bringing two such surfaces into contact and measuring the force required to separate them, we measured the surface energy of single-layer graphene in dry nitrogen to be 115 ± 4 mJ/m 2 , which was similar to that of few-layer graphene (119 ± 3 mJ/m 2 ). In water and sodium cholate, we measured interfacial energies of 83 ± 7 and 29 ± 6 mJ/m 2 , respectively. Our work provides the first direct measurement of graphene surface energy and is expected to have an impact both on the development of graphene-based devices and contribute to the fundamental understanding of surface interactions.

  16. [Thermal energy utilization analysis and energy conservation measures of fluidized bed dryer].

    PubMed

    Xing, Liming; Zhao, Zhengsheng

    2012-07-01

    To propose measures for enhancing thermal energy utilization by analyzing drying process and operation principle of fluidized bed dryers,in order to guide optimization and upgrade of fluidized bed drying equipment. Through a systematic analysis on drying process and operation principle of fluidized beds,the energy conservation law was adopted to calculate thermal energy of dryers. The thermal energy of fluidized bed dryers is mainly used to make up for thermal consumption of water evaporation (Qw), hot air from outlet equipment (Qe), thermal consumption for heating and drying wet materials (Qm) and heat dissipation to surroundings through hot air pipelines and cyclone separators. Effective measures and major approaches to enhance thermal energy utilization of fluidized bed dryers were to reduce exhaust gas out by the loss of heat Qe, recycle dryer export air quantity of heat, preserve heat for dry towers, hot air pipes and cyclone separators, dehumidify clean air in inlets and reasonably control drying time and air temperature. Such technical parameters such air supply rate, air inlet temperature and humidity, material temperature and outlet temperature and humidity are set and controlled to effectively save energy during the drying process and reduce the production cost.

  17. A reduced energy supply strategy in active vibration control

    NASA Astrophysics Data System (ADS)

    Ichchou, M. N.; Loukil, T.; Bareille, O.; Chamberland, G.; Qiu, J.

    2011-12-01

    In this paper, a control strategy is presented and numerically tested. This strategy aims to achieve the potential performance of fully active systems with a reduced energy supply. These energy needs are expected to be comparable to the power demands of semi-active systems, while system performance is intended to be comparable to that of a fully active configuration. The underlying strategy is called 'global semi-active control'. This control approach results from an energy investigation based on management of the optimal control process. Energy management encompasses storage and convenient restitution. The proposed strategy monitors a given active law without any external energy supply by considering purely dissipative and energy-demanding phases. Such a control law is offered here along with an analysis of its properties. A suboptimal form, well adapted for practical implementation steps, is also given. Moreover, a number of numerical experiments are proposed in order to validate test findings.

  18. Method for measuring the unbinding energy of strongly-bound membrane-associated proteins.

    PubMed

    Bauve, Elisa La; Vernon, Briana C; Ye, Dongmei; Rogers, David M; Siegrist, Cathryn M; Carson, Bryan D; Rempe, Susan B; Zheng, Aihua; Kielian, Margaret; Shreve, Andrew P; Kent, Michael S

    2016-11-01

    We describe a new method to measure the activation energy for unbinding (enthalpy ΔH* u and free energy ΔG* u ) of a strongly-bound membrane-associated protein from a lipid membrane. It is based on measuring the rate of release of a liposome-bound protein during centrifugation on a sucrose gradient as a function of time and temperature. The method is used to determine ΔH* u and ΔG* u for the soluble dengue virus envelope protein (sE) strongly bound to 80:20 POPC:POPG liposomes at pH5.5. ΔH* u is determined from the Arrhenius equation whereas ΔG* u is determined by fitting the data to a model based on mean first passage time for escape from a potential well. The binding free energy ΔG b of sE was also measured at the same pH for the initial, predominantly reversible, phase of binding to a 70:30 PC:PG lipid bilayer. The unbinding free energy (20±3kcal/mol, 20% PG) was found to be roughly three times the binding energy per monomer, (7.8±0.3kcal/mol for 30% PG, or est. 7.0kcal/mol for 20% PG). This is consistent with data showing that free sE is a monomer at pH5.5, but assembles into trimers after associating with membranes. This new method to determine unbinding energies should be useful to understand better the complex interactions of integral monotopic proteins and strongly-bound peripheral membrane proteins with lipid membranes. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Method for measuring the unbinding energy of strongly-bound membrane-associated proteins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    La Bauve, Elisa; Vernon, Briana C.; Ye, Dongmei

    Here, we describe a new method to measure the activation energy for unbinding (enthalpy ΔH* u and free energy ΔG* u) of a strongly-bound membrane-associated protein from a lipid membrane. It is based on measuring the rate of release of a liposome-bound protein during centrifugation on a sucrose gradient as a function of time and temperature. The method is used to determine ΔH*u and ΔG*u for the soluble dengue virus envelope protein (sE) strongly bound to 80:20 POPC:POPG liposomes at pH 5.5. ΔH*u is determined from the Arrhenius equation whereas ΔG*u is determined by fitting the data to a modelmore » based on mean first passage time for escape from a potential well. The binding free energy ΔG b of sE was also measured at the same pH for the initial, predominantly reversible, phase of binding to a 70:30 PC:PG lipid bilayer. The unbinding free energy (20 ± 3 kcal/mol, 20% PG) was found to be roughly three times the binding energy per monomer, (7.8 ± 0.3 kcal/mol for 30% PG, or est. 7.0 kcal/mol for 20% PG). This is consistent with data showing that free sE is a monomer at pH 5.5, but assembles into trimers after associating with membranes. Furthermore, this new method to determine unbinding energies should be useful to understand better the complex interactions of integral monotopic proteins and strongly-bound peripheral membrane proteins with lipid membranes.« less

  20. Method for measuring the unbinding energy of strongly-bound membrane-associated proteins

    DOE PAGES

    La Bauve, Elisa; Vernon, Briana C.; Ye, Dongmei; ...

    2016-07-15

    Here, we describe a new method to measure the activation energy for unbinding (enthalpy ΔH* u and free energy ΔG* u) of a strongly-bound membrane-associated protein from a lipid membrane. It is based on measuring the rate of release of a liposome-bound protein during centrifugation on a sucrose gradient as a function of time and temperature. The method is used to determine ΔH*u and ΔG*u for the soluble dengue virus envelope protein (sE) strongly bound to 80:20 POPC:POPG liposomes at pH 5.5. ΔH*u is determined from the Arrhenius equation whereas ΔG*u is determined by fitting the data to a modelmore » based on mean first passage time for escape from a potential well. The binding free energy ΔG b of sE was also measured at the same pH for the initial, predominantly reversible, phase of binding to a 70:30 PC:PG lipid bilayer. The unbinding free energy (20 ± 3 kcal/mol, 20% PG) was found to be roughly three times the binding energy per monomer, (7.8 ± 0.3 kcal/mol for 30% PG, or est. 7.0 kcal/mol for 20% PG). This is consistent with data showing that free sE is a monomer at pH 5.5, but assembles into trimers after associating with membranes. Furthermore, this new method to determine unbinding energies should be useful to understand better the complex interactions of integral monotopic proteins and strongly-bound peripheral membrane proteins with lipid membranes.« less

  1. Boundary displacement measurements using multi-energy soft x-rays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tritz, K., E-mail: ktritz@pppl.gov; Stutman, D.; Diallo, A.

    The Multi-Energy Soft X-ray (ME-SXR) system on NSTX provides radial profiles of soft X-ray emission, measured through a set of filters with varying thickness, which have been used to reconstruct the electron temperature on fast time scales (∼10 kHz). In addition to this functionality, here we show that the ME-SXR system can be used to measure the boundary displacement of the NSTX plasma with a few mm spatial resolution during magnetohydrodyamic (MHD) activity. Boundary displacement measurements can serve to inform theoretical predictions of neoclassical toroidal viscosity, and will be used to investigate other edge phenomena on NSTX-U. For example, boundary measurementsmore » using filtered SXR measurements can provide information on pedestal steepness and dynamic evolution leading up to and during edge localized modes (ELMs). Future applications include an assessment of a simplified, filtered SXR edge detection system as well as its suitability for real-time non-magnetic boundary feedback for ELMs, MHD, and equilibrium position control.« less

  2. Generalized energy measurements and modified transient quantum fluctuation theorems

    NASA Astrophysics Data System (ADS)

    Watanabe, Gentaro; Venkatesh, B. Prasanna; Talkner, Peter

    2014-05-01

    Determining the work which is supplied to a system by an external agent provides a crucial step in any experimental realization of transient fluctuation relations. This, however, poses a problem for quantum systems, where the standard procedure requires the projective measurement of energy at the beginning and the end of the protocol. Unfortunately, projective measurements, which are preferable from the point of view of theory, seem to be difficult to implement experimentally. We demonstrate that, when using a particular type of generalized energy measurements, the resulting work statistics is simply related to that of projective measurements. This relation between the two work statistics entails the existence of modified transient fluctuation relations. The modifications are exclusively determined by the errors incurred in the generalized energy measurements. They are universal in the sense that they do not depend on the force protocol. Particularly simple expressions for the modified Crooks relation and Jarzynski equality are found for Gaussian energy measurements. These can be obtained by a sequence of sufficiently many generalized measurements which need not be Gaussian. In accordance with the central limit theorem, this leads to an effective error reduction in the individual measurements and even yields a projective measurement in the limit of infinite repetitions.

  3. Energy Efficiency Measures to Incorporate into Remodeling Projects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liaukus, C.

    2014-12-01

    Energy improvements in a home are often approached as one concerted effort, beginning with a simple walk-through assessment or more in-depth energy audit and followed by the installation of recommended energy measures. While this approach allows for systems thinking to guide the efforts, comprehensive energy improvements of this nature are undertaken by a relatively small number of U.S. households compared to piecemeal remodeling efforts. In this report, the U.S Department of Energy Building America Retrofit Alliance research team examines the improvement of a home’s energy performance in an opportunistic way by examining what can be done to incorporate energy efficiencymore » measures into general remodeling work and home repair projects. This allows for energy efficiency upgrades to occur at the same time as remodeling proejcts. There are challenges to this approach, not the least of which being that the work will take place over time in potentially many separate projects. The opportunity to improve a home’s energy efficiency at one time expands or contracts with the scope of the remodel. As such, guidance on how to do each piece thoughtfully and with consideration for potential future projects, is critical.« less

  4. 75 FR 64348 - BOEMRE Information Collection Activity: 1010-0182, Increased Safety Measures for Energy...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-19

    ... No. BOEM-2010-0052] BOEMRE Information Collection Activity: 1010-0182, Increased Safety Measures for... the likelihood of blowouts, loss of well control, fires, spillages, physical obstruction to other... subsequent oil spill in the Gulf of Mexico. These events highlight the importance of ensuring safe operations...

  5. Predicting Activity Energy Expenditure Using the Actical[R] Activity Monitor

    ERIC Educational Resources Information Center

    Heil, Daniel P.

    2006-01-01

    This study developed algorithms for predicting activity energy expenditure (AEE) in children (n = 24) and adults (n = 24) from the Actical[R] activity monitor. Each participant performed 10 activities (supine resting, three sitting, three house cleaning, and three locomotion) while wearing monitors on the ankle, hip, and wrist; AEE was computed…

  6. Energy Cost and Enjoyment of Active Videogames in Children and Teens: Xbox 360 Kinect.

    PubMed

    Clevenger, Kimberly A; Howe, Cheryl A

    2015-08-01

    New active videogames (AVGs) may provide youth an alternative to traditional play. The purpose of this study was to compare the physical activity energy expenditure (PAEE), intensity, and enjoyment of AVGs with those of seated videogames (SVGs). Youth (8-17 years old) volunteered to play a random selection of six (two SVGs, four AVGs) videogames for 6-10 minutes each. Prior to participation, height, weight, and resting metabolic rate (RMR) were measured. A portable metabolic analyzer was worn during the games to measure total energy expenditure, and PAEE was calculated as (total energy expenditure - measured RMR). An accelerometer was worn on the right hip to measure intensity in counts/minute and steps/minute. Youth were classified as child (8-12 years old) versus teen (13-17 years old), healthy weight (body mass index [BMI] <85th percentile) versus overweight (BMI ≥85th percentile), and male versus female. A three-way mixed-model analysis of variance was used to compare differences in PAEE (metabolic equivalents [METs] and kcal/minute) with sex, weight status, and age group as main effects, including Bonferroni's adjustment. Most AVGs were moderate to vigorous intensity (4.6±0.1 METs; range, 2.8-6.6 METs), where steps/minute (lower-body movement) was positively related to PAEE (R(2)=0.68). All SVGs were classified as light intensity (1.7±0.0 METs). PAEE (kcal/minute) was significantly higher during AVGs and for teens, males, and overweight youth. There was no significant difference in enjoyment between AVGs and SVGs. AVGs elicited sufficient energy cost to be a suitable alternative for traditional play and may contribute to the recommended dose of physical activity, particularly in teens, males, and overweight youth.

  7. Concept of proton radiography using energy resolved dose measurement.

    PubMed

    Bentefour, El H; Schnuerer, Roland; Lu, Hsiao-Ming

    2016-08-21

    Energy resolved dosimetry offers a potential path to single detector based proton imaging using scanned proton beams. This is because energy resolved dose functions encrypt the radiological depth at which the measurements are made. When a set of predetermined proton beams 'proton imaging field' are used to deliver a well determined dose distribution in a specific volume, then, at any given depth x of this volume, the behavior of the dose against the energies of the proton imaging field is unique and characterizes the depth x. This concept applies directly to proton therapy scanning delivery methods (pencil beam scanning and uniform scanning) and it can be extended to the proton therapy passive delivery methods (single and double scattering) if the delivery of the irradiation is time-controlled with a known time-energy relationship. To derive the water equivalent path length (WEPL) from the energy resolved dose measurement, one may proceed in two different ways. A first method is by matching the measured energy resolved dose function to a pre-established calibration database of the behavior of the energy resolved dose in water, measured over the entire range of radiological depths with at least 1 mm spatial resolution. This calibration database can also be made specific to the patient if computed using the patient x-CT data. A second method to determine the WEPL is by using the empirical relationships between the WEPL and the integral dose or the depth at 80% of the proximal fall off of the energy resolved dose functions in water. In this note, we establish the evidence of the fundamental relationship between the energy resolved dose and the WEPL at the depth of the measurement. Then, we illustrate this relationship with experimental data and discuss its imaging dynamic range for 230 MeV protons.

  8. Energy cost of physical activities in 12-y-old girls: MET values and the influence of body weight.

    PubMed

    Spadano, J L; Must, A; Bandini, L G; Dallal, G E; Dietz, W H

    2003-12-01

    Few data exist on the energy cost of specific activities in children. The influence of body weight on the energy cost of activity when expressed as metabolic equivalents (METs) has not been vigorously explored. To provide MET data on five specific activities in 12-y-old girls and to test the hypothesis that measured MET values are independent of body weight. In 17 12-y-old girls, resting metabolic rate (RMR) and the energy expended while sitting, standing, walking on a flat treadmill at 3.2 and at 4.8 km/h, and walking on a treadmill at a 10% incline at 4.8 km/h were measured using indirect calorimetry. MET values were calculated by dividing the energy expenditure of an activity by the subject's RMR. The influence of body weight was assessed using simple linear regression. The observed METs were more consistent with published values for similar activities in adults than those offered for children. Body weight was a statistically significant predictor of the MET of all three walking activities, but not the MET of sitting or standing. Body weight explained 25% of the variance in the MET value for walking at 3.2 km/h, 39% for walking at 4.8 km/h, and 63% for walking at a 10% incline at 4.8 km/h. METs for the three walking activities were not independent of body weight. The use of average MET values to estimate the energy cost of these three activities would result in an underestimation of their energy cost in heavier girls and an overestimation in lighter girls. These results suggest that the estimation of total energy expenditure from activity diary, recall, and direct observation data using average MET values may be biased by body weight.

  9. Compact, Energy-Efficient High-Frequency Switched Capacitor Neural Stimulator With Active Charge Balancing.

    PubMed

    Hsu, Wen-Yang; Schmid, Alexandre

    2017-08-01

    Safety and energy efficiency are two major concerns for implantable neural stimulators. This paper presents a novel high-frequency, switched capacitor (HFSC) stimulation and active charge balancing scheme, which achieves high energy efficiency and well-controlled stimulation charge in the presence of large electrode impedance variations. Furthermore, the HFSC can be implemented in a compact size without any external component to simultaneously enable multichannel stimulation by deploying multiple stimulators. The theoretical analysis shows significant benefits over the constant-current and voltage-mode stimulation methods. The proposed solution was fabricated using a 0.18 μm high-voltage technology, and occupies only 0.035 mm 2 for a single stimulator. The measurement result shows 50% peak energy efficiency and confirms the effectiveness of active charge balancing to prevent the electrode dissolution.

  10. Energy Measurement Studies for CO2 Measurement with a Coherent Doppler Lidar System

    NASA Technical Reports Server (NTRS)

    Beyon, Jeffrey Y.; Koch, Grady J.; Vanvalkenburg, Randal L.; Yu, Jirong; Singh, Upendra N.; Kavaya, Michael J.

    2010-01-01

    The accurate measurement of energy in the application of lidar system for CO2 measurement is critical. Different techniques of energy estimation in the online and offline pulses are investigated for post processing of lidar returns. The cornerstone of the techniques is the accurate estimation of the spectrum of lidar signal and background noise. Since the background noise is not the ideal white Gaussian noise, simple average level estimation of noise level is not well fit in the energy estimation of lidar signal and noise. A brief review of the methods is presented in this paper.

  11. CUES - A Study Site for Measuring Snowpack Energy Balance in the Sierra Nevada

    NASA Astrophysics Data System (ADS)

    Bair, Edward; Dozier, Jeff; Davis, Robert; Colee, Michael; Claffey, Keran

    2015-09-01

    Accurate measurement and modeling of the snowpack energy balance are critical to understanding the terrestrial water cycle. Most of the water resources in the western US come from snowmelt, yet statistical runoff models that rely on the historical record are becoming less reliable because of a changing climate. For physically based snow melt models that do not depend on past conditions, ground based measurements of the energy balance components are imperative for verification. For this purpose, the US Army Corps of Engineers Cold Regions Research and Engineering Laboratory (CRREL) and the University of California, Santa Barbara (UCSB) established the “CUES” snow study site (CRREL/UCSB Energy Site, http://www.snow.ucsb.edu/) at 2940 m elevation on Mammoth Mountain, California. We describe CUES, provide an overview of research, share our experience with scientific measurements, and encourage future collaborative research. Snow measurements began near the current CUES site for ski area operations in 1969. In the 1970s, researchers began taking scientific measurements. Today, CUES benefits from year round gondola access and a fiber optic internet connection. Data loggers and computers automatically record and store over 100 measurements from more than 50 instruments each minute. CUES is one of only five high altitude mountain sites in the Western US where a full suite of energy balance components are measured. In addition to measuring snow on the ground at multiple locations, extensive radiometric and meteorological measurements are recorded. Some of the more novel measurements include scans by an automated terrestrial LiDAR, passive and active microwave imaging of snow stratigraphy, microscopic imaging of snow grains, snowflake imaging with a multi-angle camera, fluxes from upward and downward looking radiometers, snow water equivalent from different types of snow pillows, snowmelt from lysimeters, and concentration of impurities in the snowpack. We give an

  12. Associations Between Sedentary Time, Physical Activity, and Dual-Energy X-ray Absorptiometry Measures of Total Body, Android, and Gynoid Fat Mass in Children.

    PubMed

    McCormack, Lacey; Meendering, Jessica; Specker, Bonny; Binkley, Teresa

    2016-01-01

    Negative health outcomes are associated with excess body fat, low levels of physical activity (PA), and high sedentary time (ST). Relationships between PA, ST, and body fat distribution, including android and gynoid fat, assessed using dual-energy X-ray absorptiometry (DXA) have not been measured in children. The purpose of this study was to test associations between levels of activity and body composition in children and to evaluate if levels of activity predict body composition by DXA and by body mass index percentile in a similar manner. PA, ST, and body composition from 87 children (8.8-11.8 yr, grades 3-5, 44 boys) were used to test the association among study variables. Accelerometers measured PA and ST. Body composition measured by DXA included bone mineral content (BMC) and fat and lean mass of the total body (TB, less head), android, and gynoid regions. ST (range: 409-685 min/wk) was positively associated with TB percent fat (0.03, 95% confidence interval [CI]: 0.00-0.05) and android fat mass (1.5 g, 95% CI: 0.4-3.0), and inversely associated with the lean mass of the TB (-10.7 g, 95% CI: -20.8 to -0.63) and gynoid regions (-2.2 g, 95% CI: -4.3 to -0.2), and with BMC (-0.43 g, 95% CI: 0.77-0.09). Moderate-to-vigorous PA was associated with lower TB (-53 g, 95% CI: -87 to -18), android (-5 g, 95% CI: -8 to -2]), and gynoid fat (-6 g, 95% CI: -11 to -0.5). Vigorous activity results were similar. Light PA was associated with increased TB (17.1 g, 95% CI: 3.0-31.3) and gynoid lean mass (3.9 g, 95% CI: 1.0-6.8) and BMC (0.59 g, 95% CI: 0.10-1.07). In boys, there were significant associations between activity and DXA percent body fat measures that were not found with the body mass index percentile. Objective measures of PA were inversely associated with TB, android, and gynoid fat, whereas ST was directly associated with TB percent fat and, in particular, android fat. Activity levels predict body composition measures by DXA and, in

  13. Solar Energy Educational Material, Activities and Science Projects

    Science.gov Websites

    ;The sun has produced energy for billions of years. Solar energy is the solar radiation that reaches Energy - Energy from the Sun DOE Documents with Activities/Projects: Web Pages Solar Energy Education , Part I. Energy, Society, and the Sun Solar Energy Education. Reader, Part II. Sun Story. [Includes

  14. Quality of Ambulant Measures of Distance, Speed, Load and Energy Consumption During Military Operations

    DTIC Science & Technology

    2009-10-01

    Nutrition 2007, 85, 742-749. [2] Calabro, M. A., Welk, G. J. FACSM, & Eisenmann , J. C. (2007). Measurement Agreemen Between Two Pattern-Recognition Activity...Exercise Energy Expenditure. . Medicine & Science in Sports & Exercise, 36 (6), 1063-1069. [17] McClain, J. J., Welk, G. J., Wickel, E. E., & Eisenmann

  15. Activity Related Energy Expenditure, Appetite and Energy Intake: Potential Implications for Weight Management

    PubMed Central

    Harrington, D.M.; Martin, C.K.; Ravussin, E.; Katzmarzyk, P.T.

    2013-01-01

    The aim was to investigate relationships between activity related energy expenditure (AREE), appetite ratings and energy intake (EI) in a sample of 40 male (26.4 years; BMI 23.5 kg/m2) and 42 female (26.9 years; BMI 22.4 kg/m2) participants. AREE was expressed as the residual value of the regression between total daily EE (by doubly labeled water) and resting EE (by indirect calorimetry). EI was measured using an ad libitum buffet meal and visual analogue scales measured subjective appetite ratings before and after the meal. AREE was divided into low, middle and high sex-specific tertiles. General linear models were used to investigate differences in appetite ratings and EI across AREE tertiles. Before the meal, males in the high AREE tertile had significantly lower desire to eat and lower prospective food consumption and higher feelings of fullness compared to those in the low tertile. Males in the middle tertile had significantly higher satiety quotients after the meal and lower EI compared to the other tertiles. No significant differences across tertiles were found in females. Sex differences in relationships between AREE, appetite ratings and EI may lead to differing patterns of EI and subsequent weight maintenance. PMID:23523668

  16. Activity related energy expenditure, appetite and energy intake: potential implications for weight management.

    PubMed

    Harrington, D M; Martin, C K; Ravussin, E; Katzmarzyk, P T

    2013-08-01

    The aim was to investigate relationships between activity related energy expenditure (AREE), appetite ratings and energy intake (EI) in a sample of 40 male (26.4years; BMI 23.5kg/m(2)) and 42 female (26.9years; BMI 22.4kg/m(2)) participants. AREE was expressed as the residual value of the regression between total daily EE (by doubly labeled water) and resting EE (by indirect calorimetry). EI was measured using an ad libitum buffet meal and visual analogue scales measured subjective appetite ratings before and after the meal. AREE was divided into low, middle and high sex-specific tertiles. General linear models were used to investigate differences in appetite ratings and EI across AREE tertiles. Before the meal, males in the high AREE tertile had significantly lower desire to eat and lower prospective food consumption and higher feelings of fullness compared to those in the low tertile. Males in the middle tertile had significantly higher satiety quotients after the meal and lower EI compared to the other tertiles. No significant differences across tertiles were found in females. Sex differences in relationships between AREE, appetite ratings and EI may lead to differing patterns of EI and subsequent weight maintenance. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. WIND MEASUREMENTS WITH HIGH-ENERGY DOPPLER LIDAR

    NASA Technical Reports Server (NTRS)

    Koch, Grady J.; Kavaya, Michael J.; Barnes, Bruce W.; Beyon, Jeffrey Y.; Petros, Mulugeta; Jirong, Yu; Amzajerdian, Farzin; Slingh, Upendra N.

    2006-01-01

    Coherent lidars at 2-micron wavelengths from holmium or thulium solid-state lasers have been in use to measure wind for applications in meteorology, aircraft wake vortex tracking, and turbulence detection [1,2,3] These field-deployed lidars, however, have generally been of a pulse energy of a few millijoules, limiting their range capability or restricting operation to regions of high aerosol concentration such as the atmospheric boundary layer. Technology improvements in the form of high-energy pulsed lasers, low noise detectors, and high optical quality telescopes are being evaluated to make wind measurements to long ranges or low aerosol concentrations. This research is aimed at developing lidar technology for satellite-based observation of wind on a global scale. The VALIDAR project was initiated to demonstrate a high pulse energy coherent Doppler lidar. VALIDAR gets its name from the concept of validation lidar, in that it can serve as a calibration and validation source for future airborne and spaceborne lidar missions. VALIDAR is housed within a mobile trailer for field measurements.

  18. Direct measurement of exciton dissociation energy in polymers

    NASA Astrophysics Data System (ADS)

    Toušek, J.; Toušková, J.; Chomutová, R.; Paruzel, B.; Pfleger, J.

    2017-01-01

    Exciton dissociation energy was obtained based on the comparison of thickness of the space charge region estimated from the measurement of capacitance of prepared Schottky diode and from the measurement of photovoltage spectra. While the capacitance measurements provide information about the total width of the space charge region (SCR) the surface photovoltaic effect brings information only about the part of the SCR where electric field is sufficiently high to cause dissociation. For determination of the dissociation energy it is sufficient to find the electric potential in the SCR where the process starts.

  19. Get Current: Switch on Clean Energy Activity Book

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2014-06-01

    Switching on clean energy technologies means strengthening the economy while protecting the environment. This activity book for all ages promotes energy awareness, with facts on different types of energy and a variety of puzzles in an energy theme.

  20. In Vitro Effects of Sports and Energy Drinks on Streptococcus mutans Biofilm Formation and Metabolic Activity.

    PubMed

    Vinson, LaQuia A; Goodlett, Amy K; Huang, Ruijie; Eckert, George J; Gregory, Richard L

    2017-09-15

    Sports and energy drinks are being increasingly consumed and contain large amounts of sugars, which are known to increase Streptococcus mutans biofilm formation and metabolic activity. The purpose of this in vitro study was to investigate the effects of sports and energy drinks on S. mutans biofilm formation and metabolic activity. S. mutans UA159 was cultured with and without a dilution (1:3 ratio) of a variety of sports and energy drinks in bacterial media for 24 hours. The biofilm was washed, fixed, and stained. Biofilm growth was evaluated by reading absorbance of the crystal violet. Biofilm metabolic activity was measured by the biofilm-reducing XTT to a water-soluble orange compound. Gatorade Protein Recovery Shake and Starbucks Doubleshot Espresso Energy were found to significantly increase biofilm (30-fold and 22-fold, respectively) and metabolic activity (2-fold and 3-fold, respectively). However, most of the remaining drinks significantly inhibited biofilm growth and metabolic activity. Several sports and energy drinks, with sugars or sugar substitutes as their main ingredients inhibited S. mutans biofilm formation. Among the drinks evaluated, Gatorade Protein Recovery Chocolate Shake and Starbucks Doubleshot Energy appear to have cariogenic potential since they increased the biofilm formation and metabolic activity of S. mutans.

  1. Compensatory mechanisms activated with intermittent energy restriction: A randomized control trial.

    PubMed

    Coutinho, Sílvia Ribeiro; Halset, Eline Holli; Gåsbakk, Sigrid; Rehfeld, Jens F; Kulseng, Bård; Truby, Helen; Martins, Cátia

    2018-06-01

    Strong compensatory responses, with reduced resting metabolic rate (RMR), increased exercise efficiency (ExEff) and appetite, are activated when weight loss (WL) is achieved with continuous energy restriction (CER), which try to restore energy balance. Intermittent energy restriction (IER), where short spells of energy restriction are interspaced by periods of habitual energy intake, may offer some protection in minimizing those responses. We aimed to compare the effect of IER versus CER on body composition and the compensatory responses induced by WL. 35 adults (age: 39 ± 9 y) with obesity (BMI: 36 ± 4 kg/m 2 ) were randomized to lose a similar weight with an IER (N = 18) or a CER (N = 17) diet over a 12 week period. Macronutrient composition and overall energy restriction (33% reduction) were similar between groups. Body weight/composition, RMR, fasting respiratory quotient (RQ), ExEff (10, 25, and 50 W), subjective appetite ratings (hunger, fullness, desire to eat, and prospective food consumption (PFC)), and appetite-regulating hormones (active ghrelin (AG), cholecystokinin (CCK), total peptide YY (PYY), active glucagon-like peptide-1 (GLP-1), and insulin) were measured before and after WL. Changes in body weight (≈12.5% WL) and composition were similar in both groups. Fasting RQ and ExEff at 10 W increased in both groups. Losing weight, either by IER or CER dieting, did not induce significant changes in subjective appetite ratings. RMR decreased and ExEff at 25 and 50 W increased (P < 0.001 for all) in IER group only. Basal and postprandial AG increased (P < 0.05) in IER group, whereas basal active GLP-1 decreased (P = 0.033) in CER group only. Postprandial CCK decreased in both groups (P = 0.0012 and P = 0.009 for IER and CER groups, respectively). No between group differences were apparent for any of the outcomes. The technique used to achieve energy restriction, whether it is continuous or intermittent, does not appear to modulate

  2. Occupational energy expenditure and leisure-time physical activity.

    PubMed

    Kaleta, Dorota; Jegier, Anna

    2005-01-01

    In the majority of countries around the world, a decrease in the leisure-time physical activity is observed. The aim of the study was to evaluate the correlation between occupational energy expenditure and leisure-time physical activity. Moreover, the correlation between other factors and leisure-time physical activity was assessed. The study was performed in a randomly selected group of full-time employees (272 men and 236 women) living in the city of Lódź. Logistic regression was used to estimate odds ratios and 95% confidence intervals as well as to control the effects of occupational workload and leisure-time physical activity limitations. Physical activity was determined by the Seven Day Physical Activity Recall (SDPAR). Leisure-time physical activity was strongly associated with energy expenditure on occupational physical activity in men and women. Among men who expended 4000 kcal/week or more on occupational physical activity, the risk of inactivity at leisure was 1.5 times higher than in men whose weekly energy expenditure on occupational activity did not exceed 4000 kcal (adjusted OR = 1.33, 95% CI: 1.06-2.34). Among women who expended 3500 kcal/week or more on occupational physical activity, the risk of not taking up leisure-time physical activity was also higher as compared to those whose weekly energy expenditure on occupational activity was lower than 3500 kcal (adjusted OR = 1.41, 95% CI: 1.09-3.40). Prophylactic schedules associated with the improvement of leisure-time physical activity should be addressed to all adults, particularly to blue-collar workers. Future programs aimed at increasing physical activity in adults should consider work-related factors.

  3. Measurement of Activation Cross Sections Producing Short-Lived Nuclei with Pulsed Neutron Beam

    NASA Astrophysics Data System (ADS)

    Shimizu, Toshiaki; Arakita, Kazumasa; Miyazaki, Itaru; Shibata, Michihiro; Kawade, Kiyoshi; Hori, Jun-ichi; Ochiai, Kentaro; Nishitani, Takeo

    2005-05-01

    Activation cross sections for the (n, n') reaction were measured by means of the activation method at the neutron energies of 3.1 and 2.54 MeV by using a pulsed neutron beam. Target nuclei were 79Br, 90Zr, 197Au, and 207Pb, whose half-lives were between 0.8 and 8 s. The cross section for the 90Zr (n, n') 90mZr reaction was obtained for the first time in this energy range. The d-D neutrons were generated by bombarding a deuterated titanium target with a 350-keV d+ beam at the 80-degree beam line of the Fusion Neutronics Source at the Japan Atomic Energy Research Institute. In order to obtain reliable activation cross sections, careful attention was paid to correct the efficiency for a volume source, and the self-absorption of gamma rays in an irradiated sample. The systematics of the (n, n') reaction at the neutron energy of 3.1 MeV, which could be predicted within an accuracy of 50%, was proposed on the basis of our data.

  4. Measuring Dark Energy with CHIME

    NASA Astrophysics Data System (ADS)

    Newburgh, Laura; Chime Collaboration

    2015-04-01

    The Canadian Hydrogen Intensity Mapping Experiment (CHIME) is a new radio transit interferometer currently being built at the Dominion Radio Astrophysical Observatory (DRAO) in Penticton, BC, Canada. We will use the 21 cm emission line of neutral hydrogen to map baryon acoustic oscillations between 400-800 MHz across 3/4 of the sky. These measurements will yield sensitive constraints on the dark energy equation of state between redshifts 0.8 - 2.5, a fascinating but poorly probed era corresponding to when dark energy began to impact the expansion history of the Universe. I will describe theCHIME instrument, the analysis challenges, the calibration requirements, and current status.

  5. 10 CFR 35.2060 - Records of calibrations of instruments used to measure the activity of unsealed byproduct material.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Records of calibrations of instruments used to measure the activity of unsealed byproduct material. 35.2060 Section 35.2060 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2060 Records of calibrations of instruments used to measure...

  6. 10 CFR 35.2060 - Records of calibrations of instruments used to measure the activity of unsealed byproduct material.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Records of calibrations of instruments used to measure the activity of unsealed byproduct material. 35.2060 Section 35.2060 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2060 Records of calibrations of instruments used to measure...

  7. 10 CFR 35.2060 - Records of calibrations of instruments used to measure the activity of unsealed byproduct material.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Records of calibrations of instruments used to measure the activity of unsealed byproduct material. 35.2060 Section 35.2060 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2060 Records of calibrations of instruments used to measure...

  8. 10 CFR 35.2060 - Records of calibrations of instruments used to measure the activity of unsealed byproduct material.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Records of calibrations of instruments used to measure the activity of unsealed byproduct material. 35.2060 Section 35.2060 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2060 Records of calibrations of instruments used to measure...

  9. 10 CFR 35.2060 - Records of calibrations of instruments used to measure the activity of unsealed byproduct material.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Records of calibrations of instruments used to measure the activity of unsealed byproduct material. 35.2060 Section 35.2060 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2060 Records of calibrations of instruments used to measure...

  10. A Systematic Review of the Clinimetric Properties of Habitual Physical Activity Measures in Young Children with a Motor Disability

    PubMed Central

    Oftedal, Stina; Bell, Kristie L.; Mitchell, Louise E.; Davies, Peter S. W.; Ware, Robert S.; Boyd, Roslyn N.

    2012-01-01

    Aim. To identify and systematically review the clinimetric properties of habitual physical activity (HPA) measures in young children with a motor disability. Method. Five databases were searched for measures of HPA including: children aged <6.0 years with a neuromuscular disorder, physical activity defined as “bodily movement produced by skeletal muscles causing caloric expenditure”, reported HPA as duration, frequency, intensity, mode or energy expenditure, and evaluated clinimetric properties. The quality of papers was assessed using the COSMIN-checklist. A targeted search of identified measures found additional studies of typically developing young children (TDC). Results. Seven papers assessing four activity monitors met inclusion criteria. Four studies were of good methodological quality. The Minimod had good ability to measure continuous walking but the demonstrated poor ability to measure steps during free-living activities. The Intelligent Device for Energy Expenditure and Activity and Ambulatory Monitoring Pod showed poor ability to measure activity during both continuous walking and free-living activities. The StepWatch showed good ability to measure steps during continuous walking in TDC. Interpretation. Studies assessing the clinimetric properties of measures of HPA in this population are urgently needed to allow assessment of the relationship between HPA and health outcomes in this group. PMID:22927865

  11. Activation cross-section measurement of proton induced reactions on cerium

    NASA Astrophysics Data System (ADS)

    Tárkányi, F.; Hermanne, A.; Ditrói, F.; Takács, S.; Spahn, I.; Spellerberg, S.

    2017-12-01

    In the framework of a systematic study of proton induced nuclear reactions on lanthanides we have measured the excitation functions on natural cerium for the production of 142,139,138m,137Pr, 141,139,137m,137g,135Ce and 133La up to 65 MeV proton energy using the activation method with stacked-foil irradiation technique and high-resolution γ-ray spectrometry. The cross-sections of the investigated reactions were compared with the data retrieved from the TENDL-2014 and TENDL-2015 libraries, based on the latest version of the TALYS code system. No earlier experimental data were found in the literature. The measured cross-section data are important for further improvement of nuclear reaction models and for practical applications in nuclear medicine, other labeling and activation studies.

  12. A Neutron Multiplicity Meter for Deep Underground Muon-Induced High Energy Neutron Measurements

    NASA Astrophysics Data System (ADS)

    Hennings-Yeomans, Raul; Akerib, Daniel

    2007-04-01

    The nature of dark matter is one of the most important outstanding issues in particle physics, cosmology and astrophysics. A leading hypothesis is that Weakly Interacting Massive Particles, or WIMPs, were produced in the early universe and make up the dark matter. WIMP searches must be performed underground to shield from cosmic rays, which produce secondary particles that could fake a WIMP signal. Nuclear recoils from fast neutrons in underground laboratories are one of the most challenging backgrounds to WIMP detection. We present, for the first time, the design of an instrument capable of measuring the high energy (>60,eV) muon-induced neutron flux deep underground. The instrument is based on applying the Gd-loaded liquid-scintillator technique to measure the rate of multiple low energy neutron events produced in a Pb target and from this measurement to infer the rate of high energy neutron events. This unique signature allows both for efficient tagging of neutron multiplicity events as well as rejection of random gamma backgrounds so effectively that typical low-background techniques are not required. We will also discuss the benefits of using a neutron multiplicity meter as a component of active shielding.

  13. Pulse-by-pulse energy measurement at the Stanford Linear Collider

    NASA Astrophysics Data System (ADS)

    Blaylock, G.; Briggs, D.; Collins, B.; Petree, M.

    1992-01-01

    The Stanford Linear Collider (SLC) collides a beam of electrons and positrons at 92 GeV. It is the first colliding linac, and produces Z(sup 0) particles for High-Energy Physics measurements. The energy of each beam must be measured to one part in 10(exp 4) on every collision (120 Hz). An Energy Spectrometer in each beam line after the collision produces two stripes of high-energy synchrotron radiation with critical energy of a few MeV. The distance between these two stripes at an imaging plane measures the beam energy. The Wire-Imaging Synchrotron Radiation Detector (WISRD) system comprises a novel detector, data acquisition electronics, readout, and analysis. The detector comprises an array of wires for each synchrotron stripe. The electronics measure secondary emission charge on each wire of each array. A Macintosh II (using THINK C, THINK Class Library) and DSP coprocessor (using ANSI C) acquire and analyze the data, and display and report the results for SLC operation.

  14. Measures of physical activity and their correlates: the Swedish National March Cohort.

    PubMed

    Lagerros, Ylva Trolle; Bellocco, Rino; Adami, Hans-Olov; Nyrén, Olof

    2009-01-01

    We compared the results of self-estimates of physical activity obtained with a novel instrument (the Energy Expenditure Questionnaire, EEQ) to those obtained from questions typically asked in epidemiological investigations (reference method) in a cohort of 42,150 Swedish men and women, aged 18-94. In the EEQ, participants were asked to report total physical activity by estimating the total time during a typical day and night spent on different physical activity intensity levels from the lowest (corresponding to lying in bed, 0.9 Metabolic Energy Turnover; MET) to the highest, (exceeding the intensity of to shovelling snow by hand, i.e., >6 MET). As a comparison, they also estimated hours per week devoted to household chores, commuting and leisure time physical activities classified as; light, moderate and heavy. The average physical activity estimated with the EEQ was 1.36 MET or 32.6 METh/day or 2,341 kcal/day. In comparison, physical activity estimated with the reference method represented no more than 17% of this amount. The Spearman's correlation coefficient between the two measures was 0.26. Using EEQ, men reported significantly more physical activity than women (mean = 36.3 vs. 30.6 METh/day). Body mass index (BMI) > or = 25, education > or = 12 years, and age > or = 60 years were significantly associated with lower physical activity. Questions focusing on leisure time exercise and a few other selected activities provide estimates of activity that correlate poorly with self-reported total energy output from all physical activity and inactivity. Investigators need to be more explicit about which component of activity they investigate.

  15. The physical activity energy cost of the latest active video games in young adults.

    PubMed

    Howe, Cheryl A; Barr, Marcus W; Winner, Brett C; Kimble, Jenelyn R; White, Jason B

    2015-02-01

    Although promoted for weight loss, especially in young adults, it has yet to be determined if the physical activity energy expenditure (PAEE) and intensity of the newest active video games (AVGs) qualifies as moderate-to-vigorous physical activity (MVPA; > 3.0 METs). This study compared the PAEE and intensity of AVGs to traditional seated video games (SVGs). Fifty-three young adults (18-35 y; 27 females) volunteered to play 6 video games (4 AVGs, 2 SVGs). Anthropometrics and resting metabolism were measured before testing. While playing the games (6-10 min) in random order against a playmate, the participants wore a portable metabolic analyzer for measuring PAEE (kcal/min) and intensity (METs). A repeated-measures ANOVA compared the PAEE and intensity across games with sex, BMI, and PA status as main effects. The intensity of AVGs (6.1 ± 0.2 METs) was significantly greater than SVGs (1.8 ± 0.1 METs). AVGs elicited greater PAEE than SVGs in all participants (5.3 ± 0.2 vs 0.8 ± 0.0 kcal/min); PAEE during the AVGs was greater in males and overweight participants compared with females and healthy weight participants (p's < .05). The newest AVGs do qualify as MVPA and can contribute to the recommended dose of MVPA for weight management in young adults.

  16. Identification of cost effective energy conservation measures

    NASA Technical Reports Server (NTRS)

    Bierenbaum, H. S.; Boggs, W. H.

    1978-01-01

    In addition to a successful program of readily implemented conservation actions for reducing building energy consumption at Kennedy Space Center, recent detailed analyses have identified further substantial savings for buildings representative of technical facilities designed when energy costs were low. The techniques employed for determination of these energy savings consisted of facility configuration analysis, power and lighting measurements, detailed computer simulations and simulation verifications. Use of these methods resulted in identification of projected energy savings as large as $330,000 a year (approximately two year break-even period) in a single building. Application of these techniques to other commercial buildings is discussed

  17. Low energy physical activity recognition system on smartphones.

    PubMed

    Soria Morillo, Luis Miguel; Gonzalez-Abril, Luis; Ortega Ramirez, Juan Antonio; de la Concepcion, Miguel Angel Alvarez

    2015-03-03

    An innovative approach to physical activity recognition based on the use of discrete variables obtained from accelerometer sensors is presented. The system first performs a discretization process for each variable, which allows efficient recognition of activities performed by users using as little energy as possible. To this end, an innovative discretization and classification technique is presented based on the χ2 distribution. Furthermore, the entire recognition process is executed on the smartphone, which determines not only the activity performed, but also the frequency at which it is carried out. These techniques and the new classification system presented reduce energy consumption caused by the activity monitoring system. The energy saved increases smartphone usage time to more than 27 h without recharging while maintaining accuracy.

  18. The effect of a caffeinated energy drink on various psychological measures during submaximal cycling.

    PubMed

    Duncan, Michael J; Hankey, Joanne

    2013-05-27

    Caffeine containing energy drinks is commonly consumed in the belief that it will enhance the quality of an exercise session and enhance mood. However, studies examining their efficacy are sparse. The aim of this study was to examine the effect of a caffeinated energy drink on leg pain perception, perceived exertion, mood state and readiness to invest effort pre, during and post 60 min cycling exercise. Fourteen active individuals (7 males, 7 females, mean age ± S.D.=23.5 ± 3.5 years), completed two 60 min cycling trials at an intensity of 60% VO2 max preceded by ingestion of solutions containing either a caffeinated energy drink or placebo using a double-blind, deceptive, crossover design. During exercise, RPE (6-20 scale), leg pain (0-10 scale), heart rate (HR) and blood lactate (Bla) were recorded. Participants also completed measures of mood state and readiness to invest physical effort (RTIPE) pre- and post-exercise. Repeated measures analysis of variance was used to assess differences in all variables and across time and treatments, with gender used as a between subjects variable. Results indicate that HR was significantly higher (P=.002) from 30 to 60 min and RPE (P=.0001) and pain perception (P=.0001) were significantly lower from 20 to 60 min in the energy drink condition compared to placebo. Bla was significantly higher (P=.021) in the last 15 min of the energy drink trial and RTIPE (P=.001) increased significantly more from pre-ingestion to pre-exercise post-ingestion in the energy drink condition compared to placebo. No gender differences were evident (P>.05). The data revealed positive effects of energy drink ingestion on perception of exertion, leg muscle pain perception and readiness to invest effort during submaximal cycling in active adults. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. The Need for Direct High-Energy Cosmic-Ray Measurements

    NASA Technical Reports Server (NTRS)

    Jones, Frank C.; Streitmatter, Robert

    2004-01-01

    Measuring the chemical composition of the cosmic rays in the energy region of greater than or equal to 10(exp 12)eV would be highly useful in settling several nagging questions concerning the propagation of cosmic rays in the galaxy. In particular an accurate measurement of secondary to primary ratios such as Boron to Carbon would gibe clear evidence as to whether the propagation of cosmic rays is determined by a diffusion coefficient that varies with the particle's energy as E(sup 0.5) or E(sup 0.3). This would go a long ways in helping us to understand the anistropy (or lack thereof) of the highest energy cosmic rays and the power requirements for producing those particles at approximately equal to 10(exp 18) eV which are believed to be highest energy particles produced in the Galaxy. This would be only one of the benefits of a mission such as ACCESS to perform direct particle measurements on very high energy cosmic rays.

  20. The Differential Gibbs Free Energy of Activation and its Implications in the Transition-State of Enzymatic Reactions

    NASA Astrophysics Data System (ADS)

    Maggi, F.; Riley, W. J.

    2016-12-01

    We propose a mathematical framework to introduce the concept of differential free energy of activation in enzymatically catalyzed reactions, and apply it to N uptake by microalgae and bacteria. This framework extends the thermodynamic capabilities of the classical transition-state theory in and harmonizes the consolidated definitions of kinetic parameters with their thermodynamic and physical meaning. Here, the activation energy is assumed to be a necessary energetic level for equilibrium complexation between reactants and activated complex; however, an additional energy contribution is required for the equilibrium activated complex to release reaction products. We call this "differential free energy of activation"; it can be described by a Boltzmann distribution, and corresponds to a free energy level different from that of complexation. Whether this level is above or below the free energy of activation depends on the reaction, and defines energy domains that correspond to "superactivated", "activated", and "subactivated" complexes. The activated complex reaching one of those states will eventually release the products from an energy level different than that of activation. The concept of differential free energy of activation was tested on 57 independent experiments of NH­4+ and NO3- uptake by various microalgae and bacteria at temperatures ranging between 1 and 45oC. Results showed that the complexation equilibrium always favored the activated complex, but the differential energy of activation led to an apparent energy barrier consistent with observations. Temperature affected all energy levels within this framework but did not alter substantially these thermodynamic features. Overall the approach: (1) provides a thermodynamic and mathematical link between Michaelis-Menten and rate constants; (2) shows that both kinetic parameters can be described or approximated by Arrhenius' like equations; (3) describes the likelihood of formation of sub-, super-, and

  1. Measuring thermal budgets of active volcanoes by satellite remote sensing

    NASA Technical Reports Server (NTRS)

    Glaze, L.; Francis, P. W.; Rothery, D. A.

    1989-01-01

    Thematic Mapper measurements of the total radiant energy flux Q at Lascar volcano in north Chile for December 1984 are reported. The results are consistent with the earlier suggestion that a lava lake is the source of a reported thermal budget anomaly, and with values for 1985-1986 that are much lower, suggesting that fumarolic activity was then a more likely heat source. The results show that satellite remote sensing may be used to monitor the activity of a volcano quantitatively, in a way not possible by conventional ground studies, and may provide a method for predicting eruptions.

  2. Sample Energy Conservation Education Activities for Elementary School Students.

    ERIC Educational Resources Information Center

    Allen, Rodney F., Ed.; LaHart, David E., Ed.

    The booklet contains learning activities for introducing energy and conservation concepts into the existing elementary school curriculum. The activities were developed by Palm Beach County teachers during a one-week workshop. A framework of ideas is divided into three functional categories: universe of energy, living systems and energy, and social…

  3. Evaluation of dietary energy intake and physical activity in dogs undergoing a controlled weight-loss program.

    PubMed

    Wakshlag, Joseph J; Struble, Angela M; Warren, Barbour S; Maley, Mary; Panasevich, Matthew R; Cummings, Kevin J; Long, Grace M; Laflamme, Dorothy E

    2012-02-15

    To quantify physical activity and dietary energy intake in dogs enrolled in a controlled weight-loss program and assess relationships between energy intake and physical activity, sex, age, body weight, and body condition score (BCS). Prospective clinical study. 35 client-owned obese dogs (BCS > 7/9). Dogs were fed a therapeutic diet with energy intake restrictions to maintain weight loss of approximately 2%/wk. Collar-mounted pedometers were used to record the number of steps taken daily as a measure of activity. Body weight and BCS were assessed at the beginning of the weight-loss program and every 2 weeks thereafter throughout the study. Relationships between energy intake and sex, age, activity, BCS, and body weight at the end of the study were assessed via multivariable linear regression. Variables were compared among dogs stratified post hoc into inactive and active groups on the basis of mean number of steps taken (< or > 7,250 steps/d, respectively). Mean ± SD daily energy intake per unit of metabolic body weight (kg(0.75)) of active dogs was significantly greater than that of inactive dogs (53.6 ± 15.2 kcal/kg(0.75) vs 42.2 ± 9.7 kcal/kg(0.75), respectively) while maintaining weight-loss goals. In regression analysis, only the number of steps per day was significantly associated with energy intake. Increased physical activity was associated with higher energy intake while maintaining weight-loss goals. Each 1,000-step interval was associated with a 1 kcal/kg(0.75) increase in energy intake.

  4. Pulse energy measurement at the SXR instrument

    DOE PAGES

    Moeller, Stefan; Brown, Garth; Dakovski, Georgi; ...

    2015-04-14

    A gas monitor detector was implemented and characterized at the Soft X-ray Research (SXR) instrument to measure the average, absolute and pulse-resolved photon flux of the LCLS beam in the energy range between 280 and 2000 eV. The detector is placed after the monochromator and addresses the need to provide reliable absolute pulse energy as well as pulse-resolved measurements for the various experiments at this instrument. This detector provides a reliable non-invasive measurement for determining flux levels on the samples in the downstream experimental chamber and for optimizing signal levels of secondary detectors and for the essential need of datamore » normalization. The design, integration into the instrument and operation are described, and examples of its performance are given.« less

  5. The relationship between physical activity, appetite and energy intake in older adults: A systematic review.

    PubMed

    Clegg, M E; Godfrey, A

    2018-06-07

    Ageing often causes a reduction in appetite and energy intake in older adults which can result in malnutrition. Current guidelines for older adults suggest increasing physical activity to enhance appetite. However, it is unclear if there is evidence to support this advice. This aim of this review is to assess if appetite and energy intake is changed in older adults that undertake acute or regular physical activity (measured from cross sectional and intervention studies). Databases SPORTDiscus, CINAHL, MEDLINE were searched for studies between 1970 and 2017 using search terms related to ageing, physical activity (including exercise), energy and appetite. Studies included contained adults over 60 years, including acute, cross-sectional and intervention (longitudinal) studies. Of 34 full-text articles assessed, 8 were included. The Cochrane Collaboration's tool was used for assessing risk of bias. No acute studies were found. Of the cross-sectional studies, one study suggested that individuals who undertake habitual physical activity had an increased energy intake and none of the studies found differences in appetite ratings. Energy intakes increased in the intervention studies, though not always sufficiently to maintain energy balance. One study showed that ability to correctly compensate for previous energy intake was better in those that undertake habitual physical activity. The limited number of studies, wide range of data collection methodologies, time-scales and interventions mean that definitive outcomes are difficult to identify. At this stage advice to increase acute or habitual physical activity as a mean to increase appetite is not supported by sufficient evidence. Copyright © 2018. Published by Elsevier Ltd.

  6. Technique for measurement of energy loss of proton in target medium

    NASA Astrophysics Data System (ADS)

    Khadke, U. V.

    2018-05-01

    Energy loss (EL) of charged particles in target medium needs special attention, when measurements are required to be done repeatedly over periods of couple of days. It is imperative to ensure that the measurements are not affected by the long term drifts of the accelerator beam energy and the associated electronic modules. For one such situation in measurement of EL of proton beam in thick target, we optimised and standardized the technique of measuring most probable energy loss of 24.774 MeV proton in aluminium target of thickness 330 mg/cm2. The paper described the method that we developed to ensure that our EL measurements were free from effects of drifts due to any associated electronic modules. The details of the energy spectrometer, basic principle and technique for energy loss measurements in target medium are described in this paper.

  7. Home Economics. Iowa Developed Energy Activity Sampler, 6-12. Revised.

    ERIC Educational Resources Information Center

    Iowa State Dept. of Education, Des Moines. Div. of Instructional Services.

    The revised Iowa Developed Energy Activity Sampler (IDEAS) was compiled using the original IDEAS program and the Energy Conservation Activity Packets (ECAPS). This document was developed to provide home economics teachers with background information on energy, and activities that can be used/adapted with a minimum of preparation time. The…

  8. Energy storage cell impedance measuring apparatus, methods and related systems

    DOEpatents

    Morrison, John L.; Morrison, William H.; Christophersen, Jon P.

    2017-12-26

    Energy storage cell impedance testing devices, circuits, and related methods are disclosed. An energy storage cell impedance measuring device includes a sum of sinusoids (SOS) current excitation circuit including differential current sources configured to isolate a ground terminal of the differential current sources from a positive terminal and a negative terminal of an energy storage cell. A method includes applying an SOS signal comprising a sum of sinusoidal current signals to the energy storage cell with the SOS current excitation circuit, each of the sinusoidal current signals oscillating at a different one of a plurality of different frequencies. The method also includes measuring an electrical signal at a positive terminal and a negative terminal of the energy storage cell, and computing an impedance of the energy storage cell at each of the plurality of different frequencies using the measured electrical signal.

  9. Calculation versus measurement of total energy expenditure.

    PubMed

    van Lanschot, J J; Feenstra, B W; Vermeij, C G; Bruining, H A

    1986-11-01

    In acutely ill patients both hypo- and hyperalimentation must be avoided by adjusting caloric intake to total energy expenditure (TEE). We determined the discrepancy between basal energy expenditure (BEE) calculated from the basic Harris-Benedict formula and TEE measured by continuous indirect calorimetry in a heterogeneous group of mechanically ventilated surgical patients. We also compared the accuracy of TEE calculated from the corrected Harris-Benedict formula or estimated by intermittent indirect calorimetry to that of TEE measured by continuous indirect calorimetry. The poor correlation between calculated BEE and measured TEE was significantly (p less than .05) improved by a correction factor based on each patient's clinical condition. The mean absolute difference between calculated TEE and measured TEE was 8.9 +/- 9.6 (SD) %. Calculations were significantly (p less than .05) improved by estimating TEE from two 5-min recording periods, which suggests that continuous indirect calorimetry may not always be necessary to guide caloric replacement.

  10. Distance measurements from supernovae and dark energy constraints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang Yun

    2009-12-15

    Constraints on dark energy from current observational data are sensitive to how distances are measured from Type Ia supernova (SN Ia) data. We find that flux averaging of SNe Ia can be used to test the presence of unknown systematic uncertainties, and yield more robust distance measurements from SNe Ia. We have applied this approach to the nearby+SDSS+ESSENCE+SNLS+HST set of 288 SNe Ia, and the 'Constitution' set of 397 SNe Ia. Combining the SN Ia data with cosmic microwave background anisotropy data from Wilkinson Microwave Anisotropy Probe 5 yr observations, the Sloan Digital Sky Survey baryon acoustic oscillation measurements, themore » data of 69 gamma-ray bursts (GRBs) , and the Hubble constant measurement from the Hubble Space Telescope project SHOES, we measure the dark energy density function X(z){identical_to}{rho}{sub X}(z)/{rho}{sub X}(0) as a free function of redshift (assumed to be a constant at z>1 or z>1.5). Without the flux averaging of SNe Ia, the combined data using the Constitution set of SNe Ia seem to indicate a deviation from a cosmological constant at {approx}95% confidence level at 0 < or apporx. z < or approx. 0.8; they are consistent with a cosmological constant at {approx}68% confidence level when SNe Ia are flux averaged. The combined data using the nearby+SDSS+ESSENCE+SNLS+HST data set of SNe Ia are consistent with a cosmological constant at 68% confidence level with or without flux averaging of SNe Ia, and give dark energy constraints that are significantly more stringent than that using the Constitution set of SNe Ia. Assuming a flat Universe, dark energy is detected at >98% confidence level for z{<=}0.75 using the combined data with 288 SNe Ia from nearby+SDSS+ESSENCE+SNLS+HST, independent of the assumptions about X(z{>=}1). We quantify dark energy constraints without assuming a flat Universe using the dark energy figure of merit for both X(z) and a dark energy equation-of-state linear in the cosmic scale factor.« less

  11. Low energy measurements of the 10B(p ,α )7Be reaction

    NASA Astrophysics Data System (ADS)

    Wiescher, M.; deBoer, R. J.; Görres, J.; Azuma, R. E.

    2017-04-01

    Background: The 11B(p,2 α ) 4He reaction is being discussed as a prime candidate for advanced aneutronic fusion fuel systems. Particular interest in this reaction has recently emerged for laser driven plasma systems for energy generation and jet-propulsion systems. The lack of long-lived radioactive reaction products has been suggested as the main advantage of proton-boron fusion fuel. However, 19% of natural boron is 10B, with the 10B(p ,α )7Be fusion reaction producing long-lived 7Be as a side product. Purpose: A detailed measurement of the 10B(p ,α )7Be reaction over the critical energy range of hot fusion plasma environments will help to determine the amount of 7Be radioactivity being produced. This information can be used in turn to monitor the actual fusion temperature by offline measurement of the extracted 7Be activity. The goal of the here presented experiment is to expand on the results of earlier experiments, covering a wider energy range of interest for aneutronic plasma fusion applications, including also both 10B(p ,α0)7Be and the 10B(p ,α1)7Be reaction channels. Method: The reaction cross section was measured over a wide energy range from Ep=400 to 1000 keV using particle detection and from Ep=80 to 1440 keV using γ -ray spectroscopic techniques. Reaction α particles were measured at different angles to obtain angular distribution information. The results are discussed in terms of an R -matrix analysis. Results: The cross section data cover a wider energy range than previously investigated and bridge a gap in the previously available data sets. The cross sections show good agreement with previous results in the low energy region and show that the 10B(p ,α0)7Be channel is considerably larger than that of the 10B(p ,α1)7Be channel up to Ep≈1 MeV . Conclusions: The new reaction data provides important new information about the reaction cross section over the entire energy range of plasma fusion facilities. This data, when coupled with

  12. Measurement of alpha particle energy using windowless electret ion chambers.

    PubMed

    Dua, S K; Kotrappa, P; Srivastava, R; Ebadian, M A; Stieff, L R

    2002-10-01

    Electret ion chambers are inexpensive, lightweight, robust, commercially available, passive, charge-integrating devices for accurate measurement of different ionizing radiations. In an earlier work a chamber of dimensions larger than the range of alpha particles having aluminized Mylar windows of different thickness was used for measurement of alpha radiation. Correlation between electret mid-point voltage, alpha particle energy, and response was developed and it was shown that this chamber could be used for estimating the effective energy of an unknown alpha source. In the present study, the electret ion chamber is used in the windowless mode so that the alpha particles dissipate their entire energy inside the volume, and the alpha particle energy is determined from the first principles. This requires that alpha disintegration rate be accurately known or measured by an alternate method. The measured energies were within 1 to 4% of the true values for different sources (230Th, 237Np, 239Pu, 241Am, and 224Cm). This method finds application in quantitative determination of alpha energy absorbed in thin membrane and, hence, the absorbed dose.

  13. The effects of Ramadan fasting on activity and energy expenditure.

    PubMed

    Lessan, Nader; Saadane, Ilham; Alkaf, Budour; Hambly, Catherine; Buckley, Adam J; Finer, Nick; Speakman, John R; Barakat, Maha T

    2018-01-01

    Fasting during the month of Ramadan entails abstinence from eating and drinking between dawn and sunset and a major shift in meal times and patterns with associated changes in several hormones and circadian rhythms; whether there are accompanying changes in energy metabolism is unclear. We have investigated the impact of Ramadan fasting on resting metabolic rate (RMR), activity, and total energy expenditure (TEE). Healthy nonobese volunteers (n = 29; 16 women) fasting during Ramadan were recruited. RMR was measured with the use of indirect calorimetry. In subgroups of participants, activity (n = 11; 5 women) and TEE (n = 10; 5 women) in free-living conditions were measured with the use of accelerometers and the doubly labeled water technique, respectively. Body composition was measured with the use of bioelectrical impedance. Measurements were repeated after a wash-out period of between 1 and 2 mo after Ramadan. Nonparametric tests were used for comparative statistics. Ramadan fasting did not result in any change in RMR (mean ± SD: 1365.7 ± 230.2 compared with 1362.9 ± 273.6 kcal/d for Ramadan and post-Ramadan respectively, P = 0.713, n = 29). However, controlling for the effects of age, sex, and body weight, RMR was higher in the first week of Ramadan than in subsequent weeks. During Ramadan, the total number of steps walked were significantly lower (n = 11, P = 0.001), while overall sleeping time was reduced and different sleeping patterns were seen. TEE did not differ significantly between Ramadan and post-Ramadan (mean ± SD: 2224.1 ± 433.7 compared with 2121.0 ± 718.5 kcal/d for Ramadan and post-Ramadan, P = 0.7695, n = 10). Ramadan fasting is associated with reduced activity and sleeping time, but no significant change in RMR or TEE. Reported weight changes with Ramadan in other studies are more likely to be due to differences in food intake. This trial is registered at clinicaltrials.gov as NCT02696421. © 2018 American Society for Nutrition. All rights

  14. A Novel Energy-Efficient Approach for Human Activity Recognition

    PubMed Central

    Zheng, Lingxiang; Wu, Dihong; Ruan, Xiaoyang; Weng, Shaolin; Tang, Biyu; Lu, Hai; Shi, Haibin

    2017-01-01

    In this paper, we propose a novel energy-efficient approach for mobile activity recognition system (ARS) to detect human activities. The proposed energy-efficient ARS, using low sampling rates, can achieve high recognition accuracy and low energy consumption. A novel classifier that integrates hierarchical support vector machine and context-based classification (HSVMCC) is presented to achieve a high accuracy of activity recognition when the sampling rate is less than the activity frequency, i.e., the Nyquist sampling theorem is not satisfied. We tested the proposed energy-efficient approach with the data collected from 20 volunteers (14 males and six females) and the average recognition accuracy of around 96.0% was achieved. Results show that using a low sampling rate of 1Hz can save 17.3% and 59.6% of energy compared with the sampling rates of 5 Hz and 50 Hz. The proposed low sampling rate approach can greatly reduce the power consumption while maintaining high activity recognition accuracy. The composition of power consumption in online ARS is also investigated in this paper. PMID:28885560

  15. A Novel Energy-Efficient Approach for Human Activity Recognition.

    PubMed

    Zheng, Lingxiang; Wu, Dihong; Ruan, Xiaoyang; Weng, Shaolin; Peng, Ao; Tang, Biyu; Lu, Hai; Shi, Haibin; Zheng, Huiru

    2017-09-08

    In this paper, we propose a novel energy-efficient approach for mobile activity recognition system (ARS) to detect human activities. The proposed energy-efficient ARS, using low sampling rates, can achieve high recognition accuracy and low energy consumption. A novel classifier that integrates hierarchical support vector machine and context-based classification (HSVMCC) is presented to achieve a high accuracy of activity recognition when the sampling rate is less than the activity frequency, i.e., the Nyquist sampling theorem is not satisfied. We tested the proposed energy-efficient approach with the data collected from 20 volunteers (14 males and six females) and the average recognition accuracy of around 96.0% was achieved. Results show that using a low sampling rate of 1Hz can save 17.3% and 59.6% of energy compared with the sampling rates of 5 Hz and 50 Hz. The proposed low sampling rate approach can greatly reduce the power consumption while maintaining high activity recognition accuracy. The composition of power consumption in online ARS is also investigated in this paper.

  16. Measurements of fusion neutron yields by neutron activation technique: Uncertainty due to the uncertainty on activation cross-sections

    NASA Astrophysics Data System (ADS)

    Stankunas, Gediminas; Batistoni, Paola; Sjöstrand, Henrik; Conroy, Sean; JET Contributors

    2015-07-01

    The neutron activation technique is routinely used in fusion experiments to measure the neutron yields. This paper investigates the uncertainty on these measurements as due to the uncertainties on dosimetry and activation reactions. For this purpose, activation cross-sections were taken from the International Reactor Dosimetry and Fusion File (IRDFF-v1.05) in 640 groups ENDF-6 format for several reactions of interest for both 2.5 and 14 MeV neutrons. Activation coefficients (reaction rates) have been calculated using the neutron flux spectra at JET vacuum vessel, both for DD and DT plasmas, calculated by MCNP in the required 640-energy group format. The related uncertainties for the JET neutron spectra are evaluated as well using the covariance data available in the library. These uncertainties are in general small, but not negligible when high accuracy is required in the determination of the fusion neutron yields.

  17. Optimizing Lidar Scanning Strategies for Wind Energy Measurements (Invited)

    NASA Astrophysics Data System (ADS)

    Newman, J. F.; Bonin, T. A.; Klein, P.; Wharton, S.; Chilson, P. B.

    2013-12-01

    Environmental concerns and rising fossil fuel prices have prompted rapid development in the renewable energy sector. Wind energy, in particular, has become increasingly popular in the United States. However, the intermittency of available wind energy makes it difficult to integrate wind energy into the power grid. Thus, the expansion and successful implementation of wind energy requires accurate wind resource assessments and wind power forecasts. The actual power produced by a turbine is affected by the wind speeds and turbulence levels experienced across the turbine rotor disk. Because of the range of measurement heights required for wind power estimation, remote sensing devices (e.g., lidar) are ideally suited for these purposes. However, the volume averaging inherent in remote sensing technology produces turbulence estimates that are different from those estimated by a sonic anemometer mounted on a standard meteorological tower. In addition, most lidars intended for wind energy purposes utilize a standard Doppler beam-swinging or Velocity-Azimuth Display technique to estimate the three-dimensional wind vector. These scanning strategies are ideal for measuring mean wind speeds but are likely inadequate for measuring turbulence. In order to examine the impact of different lidar scanning strategies on turbulence measurements, a WindCube lidar, a scanning Halo lidar, and a scanning Galion lidar were deployed at the Southern Great Plains Atmospheric Radiation Measurement (ARM) site in Summer 2013. Existing instrumentation at the ARM site, including a 60-m meteorological tower and an additional scanning Halo lidar, were used in conjunction with the deployed lidars to evaluate several user-defined scanning strategies. For part of the experiment, all three scanning lidars were pointed at approximately the same point in space and a tri-Doppler analysis was completed to calculate the three-dimensional wind vector every 1 second. In another part of the experiment, one of

  18. Ligand reorganization and activation energies in nonadiabatic electron transfer reactions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu Jianjun; Wang Jianji; Stell, George

    2006-10-28

    The activation energy and ligand reorganization energy for nonadiabatic electron transfer reactions in chemical and biological systems are investigated in this paper. The free energy surfaces and the activation energy are derived exactly in the general case in which the ligand vibration frequencies are not equal. The activation energy is derived by free energy minimization at the transition state. Our formulation leads to the Marcus-Hush [J. Chem. Phys. 24, 979 (1956); 98, 7170 (1994); 28, 962 (1958)] results in the equal-frequency limit and also generalizes the Marcus-Sumi [J. Chem. Phys. 84, 4894 (1986)] model in the context of studying themore » solvent dynamic effect on electron transfer reactions. It is found that when the ligand vibration frequencies are different, the activation energy derived from the Marcus-Hush formula deviates by 5%-10% from the exact value. If the reduced reorganization energy approximation is introduced in the Marcus-Hush formula, the result is almost exact.« less

  19. Ligand reorganization and activation energies in nonadiabatic electron transfer reactions

    NASA Astrophysics Data System (ADS)

    Zhu, Jianjun; Wang, Jianji; Stell, George

    2006-10-01

    The activation energy and ligand reorganization energy for nonadiabatic electron transfer reactions in chemical and biological systems are investigated in this paper. The free energy surfaces and the activation energy are derived exactly in the general case in which the ligand vibration frequencies are not equal. The activation energy is derived by free energy minimization at the transition state. Our formulation leads to the Marcus-Hush [J. Chem. Phys. 24, 979 (1956); 98, 7170 (1994); 28, 962 (1958)] results in the equal-frequency limit and also generalizes the Marcus-Sumi [J. Chem. Phys. 84, 4894 (1986)] model in the context of studying the solvent dynamic effect on electron transfer reactions. It is found that when the ligand vibration frequencies are different, the activation energy derived from the Marcus-Hush formula deviates by 5%-10% from the exact value. If the reduced reorganization energy approximation is introduced in the Marcus-Hush formula, the result is almost exact.

  20. Comparison of resting and total energy expenditure in peritoneal dialysis patients and body composition measured by dual-energy X-ray absorptiometry.

    PubMed

    El-Kateb, S; Sridharan, S; Farrington, K; Davenport, A

    2016-11-01

    Under basal resting conditions muscle metabolism is reduced, whereas metabolism increases with physical activity. We wished to determine whether there was an association between resting energy expenditure (REE) and total energy expenditure (TEE) in peritoneal dialysis (PD) patients and lean body mass (LBM). We determined REE and TEE by recently validated equations, using doubly labelled isotopic water, and LBM by dual-energy X-ray absorptiometry (DXA) scanning. We studied 87 patients, 50 male (57.4%), 25 diabetic (28.7%), mean age 60.3±17.6 years, with a median PD treatment of 11.4 (4.7-29.5) months. The mean weight was 70.1±17.7 kg with a REE of 1509±245 kcal/day and TEE 1947±378 kcal/day. REE was associated with body size (weight r=0.78 and body mass index (BMI) r=0.72) and body composition (LBM r=0.77, lean body mass index (LBMI) r=0.76, r=0.62), all P<0.001). For TEE, there was an association with weight r=0.58, BMI r=0.49 and body composition (LBM r=0.64, LBMI (r=0.54), all P<0.001). We compared LBMI measured by DXA and that estimated by the Boer equation using anthropomorphic measurements, which overestimated and underestimated LBM for smaller patients and heavier patients, respectively. Muscle metabolism is reduced at rest and increases with physical activity. Whereas previous reports based on REE did not show any association with LBM, we found an association between both REE and TEE, using a recently validated equation derived from dialysis patients, and LBM measured by DXA scanning. Estimation of muscle mass from anthropomorphic measurements systematically overestimated LBM for small patients and conversely underestimated for heavier patients.

  1. 10 CFR 431.16 - Test procedures for the measurement of energy efficiency.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Test procedures for the measurement of energy efficiency. 431.16 Section 431.16 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR... Methods of Determining Efficiency § 431.16 Test procedures for the measurement of energy efficiency. For...

  2. 10 CFR 431.16 - Test procedures for the measurement of energy efficiency.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Test procedures for the measurement of energy efficiency. 431.16 Section 431.16 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR... Methods of Determining Efficiency § 431.16 Test procedures for the measurement of energy efficiency. For...

  3. Energy Efficiency Measures to Incorporate into Remodeling Projects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liaukus, C.

    2014-12-01

    Energy improvements in a home are often approached as one concerted effort, beginning with a simple walk-through assessment or more in-depth energy audit and followed by the installation of recommended energy measures. While this approach allows for systems thinking to guide the efforts, comprehensive energy improvements of this nature are undertaken by a relatively small number of the households in our nation compared to more piecemeal remodeling efforts. Even when programs like the Weatherization Assistance Program and Home Performance with ENERGY STAR are considered, homes that have had a comprehensive energy makeover still represent a small fraction of the 111.1more » million households. In this report, the U.S Department of Energy Building America Retrofit Alliance research team looks at the improvement of a home's energy performance in an opportunistic way: it examines what can be done to incorporate energy efficiency measures into general remodeling work and home repair projects. This allows for the possibility for people who would not normally pursue energy efficiency but will remodel their kitchen or re-side their home to improve their home's performance at the same time. There are challenges to this approach, not the least of which being that the work will take place over time in potentially many separate projects. The opportunity to improve a home's energy efficiency at one time expands or contracts with the scope of the remodel. As such, guidance on how to do each piece thoughtfully and with consideration for potential future projects, is critical.« less

  4. 10 CFR 431.444 - Test procedures for the measurement of energy efficiency.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Test procedures for the measurement of energy efficiency. 431.444 Section 431.444 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR... procedures for the measurement of energy efficiency. (a) Scope. Pursuant to section 346(b)(1) of EPCA, this...

  5. 10 CFR 431.444 - Test procedures for the measurement of energy efficiency.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Test procedures for the measurement of energy efficiency. 431.444 Section 431.444 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR... procedures for the measurement of energy efficiency. (a) Scope. Pursuant to section 346(b)(1) of EPCA, this...

  6. Effects of Energy Drinks on Economy and Cardiovascular Measures.

    PubMed

    Peveler, Willard W; Sanders, Gabe J; Marczinski, Cecile A; Holmer, Brady

    2017-04-01

    Peveler, WW, Sanders, GJ, Marczinski, CA, and Holmer, B. Effects of energy drinks on economy and cardiovascular measures. J Strength Cond Res 31(4): 882-887, 2017-The use of energy drinks among athletes has risen greatly. Caffeine and taurine are the 2 primary performance enhancing ingredients found in energy drinks. The number of emergency department visits involving energy drinks doubled over the past 5 years. Reviews of the health complications have highlighted adverse cardiovascular events. The literature reveals that caffeine is known to moderately increase blood pressure (BP) and heart rate (HR). The purpose of this study was to determine the effect of 3 different energy drinks on cardiovascular and performance measures. Fifteen recreational runners completed 5 trials. The first trial consisted of a graded exercise protocol. The 4 remaining trials consisted of 15-minute economy trials at a treadmill speed consistent with 70% of subject's V[Combining Dot Above]O2max. An hour before subjects ingested 1 of the 3 energy drinks or a placebo. HR, BP, V[Combining Dot Above]O2, and rating of perceived exertion (RPE) were recorded during the 15-minute trial. Mean values for dependent measures were compared using repeated-measures analysis of variance. Fifteen-minute systolic BP readings were significantly lower in the placebo trials (156.93 ± 15.50) in relation to the 3 energy drink trials (163.87 ± 13.30, 166.47 ± 13.71, and 165.00 ± 15.23). There were no significant differences in diastolic BP and HR. There were no significant differences found in V[Combining Dot Above]O2 or RPE measures. Ingestion of energy drinks demonstrated no change in V[Combining Dot Above]O2 or RPE during the economy trials. The findings show no performance benefits under the conditions of this study. However, there does appear to be a significant increase in systolic BP.

  7. Hybrid energy storage systems utilizing redox active organic compounds

    DOEpatents

    Wang, Wei; Xu, Wu; Li, Liyu; Yang, Zhenguo

    2015-09-08

    Redox flow batteries (RFB) have attracted considerable interest due to their ability to store large amounts of power and energy. Non-aqueous energy storage systems that utilize at least some aspects of RFB systems are attractive because they can offer an expansion of the operating potential window, which can improve on the system energy and power densities. One example of such systems has a separator separating first and second electrodes. The first electrode includes a first current collector and volume containing a first active material. The second electrode includes a second current collector and volume containing a second active material. During operation, the first source provides a flow of first active material to the first volume. The first active material includes a redox active organic compound dissolved in a non-aqueous, liquid electrolyte and the second active material includes a redox active metal.

  8. Possibility of cellulose-based electro-active paper energy scavenging transducer.

    PubMed

    Abas, Zafar; Kim, Heung Soo; Zhai, Lindong; Kim, Jaehwan; Kim, Joo Hyung

    2014-10-01

    In this paper, a cellulose-based Electro-Active Paper (EAPap) energy scavenging transducer is presented. Cellulose is proven as a smart material, and exhibits piezoelectric effect. Specimens were prepared by coating gold electrodes on both sides of cellulose film. The fabricated specimens were tested by a base excited aluminum cantilever beam at resonant frequency. Different tests were performed with single and multiple parallel connected electrodes coated on the cellulose film. A maximum of 131 mV output voltage was measured, when three electrodes were connected in parallel. It was observed that voltage output increases significantly with the area of electrodes. From these results, it can be concluded that the piezoelectricity of cellulose-based EAPap can be used in energy transduction application.

  9. Energy utilization associated with regular activity breaks and continuous physical activity: A randomized crossover trial.

    PubMed

    Fenemor, S P; Homer, A R; Perry, T L; Skeaff, C M; Peddie, M C; Rehrer, N J

    2018-06-01

    To quantify and compare energy utilization associated with prolonged sitting alone, or interrupted with regular activity breaks and/or an additional bout of continuous physical activity. Thirty six adults (11 males, BMI 24.1 ± 4.6) completed four interventions: (1) prolonged sitting (SIT), (2) sitting with 2-min of walking every 30 min (RAB), (3) prolonged sitting with 30-min of continuous walking at the end of the day (SIT + PA), (4) a combination of the activities in (2) and (3) above (RAB + PA). All walking was at a speed and incline corresponding to 60% V̇O 2max . Energy utilization over 7 h for each intervention was estimated using indirect calorimetry. Compared to SIT, SIT + PA increased total energy utilization by 709 kJ (95% CI 485-933 kJ), RAB by 863 kJ (95% CI 638-1088 kJ), and RAB + PA by 1752 kJ (95% CI 1527-1927 kJ) (all p < 0.001). There was no difference in total energy utilization between SIT + PA and RAB, however, post-physical activity energy utilization in RAB was 632 kJ greater than SIT + PA (95% CI 561-704 kJ; p < 0.001). Short frequent activity, results in greater accumulation of elevated post-physical activity energy utilization compared to a single bout of continuous activity; however the total energy utilization is similar. Combining activity breaks with a longer continuous bout of activity will further enhance energy utilization, and in the longer term, may positively affect weight management of a greater magnitude than either activity pattern performed alone. ANZCTR12614000624684. Copyright © 2018 The Italian Society of Diabetology, the Italian Society for the Study of Atherosclerosis, the Italian Society of Human Nutrition, and the Department of Clinical Medicine and Surgery, Federico II University. Published by Elsevier B.V. All rights reserved.

  10. Resting sympathetic activity is associated with the sympathetically mediated component of energy expenditure following a meal.

    PubMed

    Limberg, Jacqueline K; Malterer, Katherine R; Matzek, Luke J; Levine, James A; Charkoudian, Nisha; Miles, John M; Joyner, Michael J; Curry, Timothy B

    2017-08-01

    Individuals with high plasma norepinephrine (NE) levels at rest have a smaller reduction in resting energy expenditure (REE) following β -adrenergic blockade. If this finding extends to the response to a meal, it could have important implications for the role of the sympathetic nervous system in energy balance and weight gain. We hypothesized high muscle sympathetic nerve activity (MSNA) would be associated with a low sympathetically mediated component of energy expenditure following a meal. Fourteen young, healthy adults completed two visits randomized to continuous saline (control) or intravenous propranolol to achieve systemic β -adrenergic blockade. Muscle sympathetic nerve activity and REE were measured (indirect calorimetry) followed by a liquid mixed meal (Ensure). Measures of energy expenditure continued every 30 min for 5 h after the meal and are reported as an area under the curve (AUC). Sympathetic support of energy expenditure was calculated as the difference between the AUC during saline and β -blockade (AUC P ropranolol -AUC S aline , β -REE) and as a percent (%) of control (AUC P ropranolol ÷AUC S aline  × 100). β -REE was associated with baseline sympathetic activity, such that individuals with high resting MSNA (bursts/100 heart beats) and plasma NE had the greatest sympathetically mediated component of energy expenditure following a meal (MSNA: β -REE R  =   -0.58, P =  0.03; %REE R  = -0.56, P =  0.04; NE: β -REE R  = -0.55, P  = 0.0535; %REE R  = -0.54, P  = 0.0552). Contrary to our hypothesis, high resting sympathetic activity is associated with a greater sympathetically mediated component of energy expenditure following a liquid meal. These findings may have implications for weight maintenance in individuals with varying resting sympathetic activity. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  11. NREL: International Activities - Fourth Renewable Energy Industries Forum

    Science.gov Websites

    Speakers and Presentations International Activities Printable Version Fourth Renewable Energy Industries Forum Speakers and Presentations The Fourth Renewable Energy Industries Forum (REIF) speakers and practices, opportunities and challenges of utility and distributed projects, renewable energy integration

  12. Channeling Children's Energy through Vocabulary Activities

    ERIC Educational Resources Information Center

    Schindler, Andrea

    2006-01-01

    In this article, the author shares vocabulary development activities for young learners. These activities channel students' energy and make learning more effective and fun. The author stresses the importance of giving young learners a good language-learning experience, and the challenges of teaching young learners who are not literate in their L1.…

  13. Stress versus temperature dependent activation energies in creep

    NASA Technical Reports Server (NTRS)

    Freed, A. D.; Raj, S. V.; Walker, K. P.

    1990-01-01

    The activation energy for creep at low stresses and elevated temperatures is lattice diffusion, where the rate controlling mechanism for deformation is dislocation climb. At higher stresses and intermediate temperatures, the rate controlling mechanism changes from that of dislocation climb to one of obstacle-controlled dislocation glide. Along with this change, there occurs a change in the activation energy. It is shown that a temperature-dependent Gibbs free energy does a good job of correlating steady-state creep data, while a stress-dependent Gibbs free energy does a less desirable job of correlating the same data. Applications are made to copper and a LiF-22 mol. percent CaF2 hypereutectic salt.

  14. Measurement of Energy Performances for General-Structured Servers

    NASA Astrophysics Data System (ADS)

    Liu, Ren; Chen, Lili; Li, Pengcheng; Liu, Meng; Chen, Haihong

    2017-11-01

    Energy consumption of servers in data centers increases rapidly along with the wide application of Internet and connected devices. To improve the energy efficiency of servers, voluntary or mandatory energy efficiency programs for servers, including voluntary label program or mandatory energy performance standards have been adopted or being prepared in the US, EU and China. However, the energy performance of servers and testing methods of servers are not well defined. This paper presents matrices to measure the energy performances of general-structured servers. The impacts of various components of servers on their energy performances are also analyzed. Based on a set of normalized workload, the author proposes a standard method for testing energy efficiency of servers. Pilot tests are conducted to assess the energy performance testing methods of servers. The findings of the tests are discussed in the paper.

  15. Energy Expenditure and Intensity of Physical Activity in Soccer Referees During Match-Play

    PubMed Central

    da Silva, Alberto Inácio; Fernandes, Luiz Cláudio; Fernandez, Ricardo

    2008-01-01

    In order to elaborate a diet that sufficiently restores the athlete’s energy expenditure during training and/or competition, the first step would be to measure energy expenditure during activity.We observed that during officials matches soccer referees perform physical aerobic activities of low and moderate intensity, and present a significant decline in energy expenditure between the first and second half.The pattern of movement observed in the present report confirms that soccer referees, like players undertake intermittent type exercise.Nutritional habits of soccer referees must be adapted to their daily physical activities, short training periods and moderate energy intensity physical activity, on average, during match refereeing. PMID:24149899

  16. Energy expenditure and intensity of physical activity in soccer referees during match-play.

    PubMed

    da Silva, Alberto Inácio; Fernandes, Luiz Cláudio; Fernandez, Ricardo

    2008-01-01

    In order to elaborate a diet that sufficiently restores the athlete's energy expenditure during training and/or competition, the first step would be to measure energy expenditure during activity.We observed that during officials matches soccer referees perform physical aerobic activities of low and moderate intensity, and present a significant decline in energy expenditure between the first and second half.The pattern of movement observed in the present report confirms that soccer referees, like players undertake intermittent type exercise.Nutritional habits of soccer referees must be adapted to their daily physical activities, short training periods and moderate energy intensity physical activity, on average, during match refereeing.

  17. Investigation of Activation Cross Sections of the Proton Induced Nuclear Reactions on Natural Iron at Medium Energies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ditroi, F.; Tarkanyi, F.; Csikai, J.

    2005-05-24

    Iron is one of the most important structural materials in every field of science, technology, industry, etc. Its application in a radiating environment requires the knowledge of accurate excitation functions for the possible reactions in question. By using the Thin Layer Activation technique (TLA) the knowledge of such data is also extremely important even in the case of relative measurements to design the irradiation (irradiation energy, beam intensity, duration) and also for radioactive safety estimations. The cross sections are frequently measured at low energies but there are unsatisfactory and unreliable data in the energy range above 40 MeV.

  18. Investigation of Activation Cross Sections of the Proton Induced Nuclear Reactions on Natural Iron at Medium Energies

    NASA Astrophysics Data System (ADS)

    Ditrói, F.; Tárkányi, F.; Csikai, J.; Uddin, M. S.; Hagiwara, M.; Baba, M.

    2005-05-01

    Iron is one of the most important structural materials in every field of science, technology, industry, etc. Its application in a radiating environment requires the knowledge of accurate excitation functions for the possible reactions in question. By using the Thin Layer Activation technique (TLA) the knowledge of such data is also extremely important even in the case of relative measurements to design the irradiation (irradiation energy, beam intensity, duration) and also for radioactive safety estimations. The cross sections are frequently measured at low energies but there are unsatisfactory and unreliable data in the energy range above 40 MeV.

  19. Activation energy associated with the electromigration of oligosaccharides through viscosity modifier and polymeric additive containing background electrolytes.

    PubMed

    Kerékgyártó, Márta; Járvás, Gábor; Novák, Levente; Guttman, András

    2016-02-01

    The activation energy related to the electromigration of oligosaccharides can be determined from their measured electrophoretic mobilities at different temperatures. The effects of a viscosity modifier (ethylene glycol) and a polymeric additive (linear polyacrylamide) on the electrophoretic mobility of linear sugar oligomers with α1-4 linked glucose units (maltooligosaccharides) were studied in CE using the activation energy concept. The electrophoretic separations of 8-aminopyrene-1,3,6-trisulfonate-labeled maltooligosaccharides were monitored by LIF detection in the temperature range of 20-50°C, using either 0-60% ethylene glycol (viscosity modifier) or 0-3% linear polyacrylamide (polymeric additive) containing BGEs. Activation energy curves were constructed based on the slopes of the Arrhenius plots. With the use of linear polyacrylamide additive, solute size-dependent activation energy variations were found for the maltooligosaccharides with polymerization degrees below and above maltoheptaose (DP 7), probably due to molecular conformation changes and possible matrix interaction effects. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Activation Energy of Tantalum-Tungsten Oxide Thermite Reaction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cervantes, O; Kuntz, J; Gash, A

    2010-02-25

    The activation energy of a high melting temperature sol-gel (SG) derived tantalum-tungsten oxide thermite composite was determined using the Kissinger isoconversion method. The SG derived powder was consolidated using the High Pressure Spark Plasma Sintering (HPSPS) technique to 300 and 400 C to produce pellets with dimensions of 5 mm diameter by 1.5 mm height. A custom built ignition setup was developed to measure ignition temperatures at high heating rates (500-2000 C {center_dot} min{sup -1}). Such heating rates were required in order to ignite the thermite composite. Unlike the 400 C samples, results show that the samples consolidated to 300more » C undergo an abrupt change in temperature response prior to ignition. This change in temperature response has been attributed to the crystallization of the amorphous WO{sub 3} in the SG derived Ta-WO{sub 3} thermite composite and not to a pre-ignition reaction between the constituents. Ignition temperatures for the Ta-WO{sub 3} thermite ranged from approximately 465-670 C. The activation energy of the SG derived Ta-WO{sup 3} thermite composite consolidated to 300 and 400 C were determined to be 37.787 {+-} 1.58 kJ {center_dot} mol{sup -1} and 57.381 {+-} 2.26 kJ {center_dot} mol{sup -1}, respectively.« less

  1. Physical activity in an indigenous Ecuadorian forager-horticulturalist population as measured using accelerometry.

    PubMed

    Madimenos, Felicia C; Snodgrass, J Josh; Blackwell, Aaron D; Liebert, Melissa A; Sugiyama, Lawrence S

    2011-01-01

    Minimal information on physical activity is available for non-Western populations undergoing the transition to a market economy. This is unfortunate given the importance of these data for understanding health issues such as the global obesity epidemic. We consider the utility of using accelerometry technology to examine activity patterns and energy use regulation among indigenous Shuar, an Ecuadorian forager-horticulturalist population undergoing economic and lifestyle change. We investigate sex differences in Shuar activity patterns and the effects of reproductive status on activity. Finally, we discuss the potential of accelerometry use in human biology research. Physical activity levels were measured using Actical accelerometers in 49 indigenous Shuar adults (23 males, 26 females) from a rural Ecuadorian community. Female participants were in various reproductive states including pregnant, lactating, and nonpregnant/nonlactating. Activity counts (AC), activity energy expenditure (AEE), and physical activity levels (PAL) were significantly higher (P < 0.05) in males than females. Significant differences in energy expenditure were found among pregnant or lactating females and males with pregnant or lactating partners (P < 0.001). Males with pregnant or lactating partners also had significantly higher activity levels than did other men (P < 0.01). Shuar activity levels are relatively low compared to other non-Western populations. Despite increasing market integration, pregnant and lactating females seem to be adopting a strategy noted in other subsistence populations where male participation in subsistence activities increases to compensate for their partners' elevated reproductive costs. Despite certain limitations, use of accelerometry in human biology research shows promise. Copyright © 2011 Wiley-Liss, Inc.

  2. Physical activity in an indigenous Ecuadorian forager-horticulturalist population as measured using accelerometry

    PubMed Central

    Madimenos, Felicia C.; Snodgrass, J. Josh; Blackwell, Aaron D.; Liebert, Melissa A.; Sugiyama, Lawrence S.

    2011-01-01

    Objective Minimal information on physical activity is available for non-Western populations undergoing the transition to a market economy. This is unfortunate given the importance of these data for understanding health issues such as the global obesity epidemic. We consider the utility of using accelerometry technology to examine activity patterns and energy use regulation among indigenous Shuar, an Ecuadorian forager-horticulturalist population undergoing economic and lifestyle change. We investigate sex differences in Shuar activity patterns and the effects of reproductive status on activity. Finally, we discuss the potential of accelerometry use in human biology research. Methods Physical activity levels were measured using Actical accelerometers in 49 indigenous Shuar adults (23 males, 26 females) from a rural Ecuadorian community. Female participants were in various reproductive states including pregnant, lactating, and non-pregnant/non-lactating. Results Activity counts (AC), activity energy expenditure (AEE), and physical activity levels (PAL) were significantly higher (P < 0.05) in males than females. Significant differences in energy expenditure were found among pregnant or lactating females and males with pregnant or lactating partners (P < 0.001). Males with pregnant or lactating partners also had significantly higher activity levels than did other men (P < 0.01). Conclusions Shuar activity levels are relatively low compared to other non-Western populations. Despite increasing market integration, pregnant and lactating females seem to be adopting a strategy noted in other subsistence populations where male participation in subsistence activities increases to compensate for their partners’ elevated reproductive costs. Despite certain limitations, use of accelerometry in human biology research shows promise. PMID:21538650

  3. Quantify the energy and environmental benefits of implementing energy-efficiency measures in China’s iron and steel production

    DOE PAGES

    Ma, Ding; Chen, Wenying; Xu, Tengfang

    2015-08-21

    As one of the most energy-, emission- and pollution-intensive industries, iron and steel production is responsible for significant emissions of greenhouse gas (GHG) and air pollutants. Although many energy-efficiency measures have been proposed by the Chinese government to mitigate GHG emissions and to improve air quality, lacking full understanding of the costs and benefits has created barriers against implementing these measures widely. This paper sets out to advance the understanding by addressing the knowledge gap in costs, benefits, and cost-effectiveness of energy-efficiency measures in iron and steel production. Specifically, we build a new evaluation framework to quantify energy benefits andmore » environmental benefits (i.e., CO 2 emission reduction, air-pollutants emission reduction and water savings) associated with 36 energy-efficiency measures. Results show that inclusion of benefits from CO 2 and air-pollutants emission reduction affects the cost-effectiveness of energy-efficiency measures significantly, while impacts from water-savings benefits are moderate but notable when compared to the effects by considering energy benefits alone. The new information resulted from this study should be used to augment future programs and efforts in reducing energy use and environmental impacts associated with steel production.« less

  4. Quantify the energy and environmental benefits of implementing energy-efficiency measures in China’s iron and steel production

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, Ding; Chen, Wenying; Xu, Tengfang

    As one of the most energy-, emission- and pollution-intensive industries, iron and steel production is responsible for significant emissions of greenhouse gas (GHG) and air pollutants. Although many energy-efficiency measures have been proposed by the Chinese government to mitigate GHG emissions and to improve air quality, lacking full understanding of the costs and benefits has created barriers against implementing these measures widely. This paper sets out to advance the understanding by addressing the knowledge gap in costs, benefits, and cost-effectiveness of energy-efficiency measures in iron and steel production. Specifically, we build a new evaluation framework to quantify energy benefits andmore » environmental benefits (i.e., CO 2 emission reduction, air-pollutants emission reduction and water savings) associated with 36 energy-efficiency measures. Results show that inclusion of benefits from CO 2 and air-pollutants emission reduction affects the cost-effectiveness of energy-efficiency measures significantly, while impacts from water-savings benefits are moderate but notable when compared to the effects by considering energy benefits alone. The new information resulted from this study should be used to augment future programs and efforts in reducing energy use and environmental impacts associated with steel production.« less

  5. Computer simulated building energy consumption for verification of energy conservation measures in network facilities

    NASA Technical Reports Server (NTRS)

    Plankey, B.

    1981-01-01

    A computer program called ECPVER (Energy Consumption Program - Verification) was developed to simulate all energy loads for any number of buildings. The program computes simulated daily, monthly, and yearly energy consumption which can be compared with actual meter readings for the same time period. Such comparison can lead to validation of the model under a variety of conditions, which allows it to be used to predict future energy saving due to energy conservation measures. Predicted energy saving can then be compared with actual saving to verify the effectiveness of those energy conservation changes. This verification procedure is planned to be an important advancement in the Deep Space Network Energy Project, which seeks to reduce energy cost and consumption at all DSN Deep Space Stations.

  6. Energy utilization rates during shuttle extravehicular activities.

    PubMed

    Waligora, J M; Kumar, K V

    1995-01-01

    The work rates or energy utilization rates during EVA are major factors in sizing of life support systems. These rates also provide a measure of ease of EVA and its cost in crew fatigue. From the first Shuttle EVA on the STS-6 mission in 1983, we have conducted 59 man-EVA and 341 man-hours of EVA. Energy utilization rates have been measured on each of these EVA. Metabolic rate was measured during each EVA using oxygen utilization corrected for suit leakage. From 1981-1987, these data were available for average data over the EVA or over large segments of the EVA. Since 1987, EVA oxygen utilization data were available at 2-minute intervals. The average metabolic rate on Shuttle EVA (194 kcal/hr.) has been significantly lower than metabolic rates during Apollo and Skylab missions. Peak rates have been below design levels, infrequent, and of short duration. The data suggest that the energy cost of tasks may be inversely related to the degree of training for the task. The data provide insight on the safety margins provided by life support designs and on the energy cost of Station construction EVA.

  7. Measuring Photosynthetic Response to Drought Stress using Active and Passive Fluorescence

    NASA Astrophysics Data System (ADS)

    Helm, L.; Lerdau, M.; Wang, W.; Yang, X.

    2017-12-01

    Photosynthesis, the endothermic reactions involving the absorption of light and fixation and reduction of carbon dioxide by plants, plays important roles in carbon and water cycles, food security, and even weather and climate patterns. Solar radiation provides the energy for photosynthesis, but often plants absorb more solar energy than they can use to reduce carbon dioxide. This excess energy, which is briefly stored as high-energy electrons in the chloroplast, must be removed or damage to the leaf's photosynthetic machinery will occur. One important energy dissipation pathway is for the high energy electrons to return to their lower valance state and, in doing so, release radiation (fluorescence). This fluorescence (known as solar induced fluorescence (SIF) has been found to strongly correlate with gross photosynthesis. Recent advances in the remote sensing of SIF allow for large-scale real-time estimation of photosynthesis. In a warming climate with more frequent stress, remote sensing is necessary for measuring the spatial and temporal variability of photosynthesis. However, the mechanisms that link SIF and photosynthesis are unclear, particularly how the relationship may or may not change under stress. We present data from leaf-level measurements of gas exchange, pulse amplitude modulation (PAM) fluorescence, and SIF in two major tree species in North America. Water-stressed and well-watered plants were compared to determine how SIF and carbon dioxide exchange are modulated by drought diurnally and seasonally. Secondly, photosynthesis and fluorescence under high and low oxygen concentrations were compared to determine how photorespiration alters the relationship between SIF and gross photosynthesis. We find a strong correlation between SIF and steady-state fluorescence measured with conventional PAM fluorometry. Our results also indicate that drought-stress modulates the SIF-photosynthesis relationship, and this may be driven by drought-induced changes in

  8. Energy balance, physical activity, and cancer risk.

    PubMed

    Fair, Alecia Malin; Montgomery, Kara

    2009-01-01

    This chapter posits that cancer is a complex and multifactorial process as demonstrated by the expression and production of key endocrine and steroid hormones that intermesh with lifestyle factors (physical activity, body size, and diet) in combination to heighten cancer risk. Excess weight has been associated with increased mortality from all cancers combined and for cancers of several specific sites. The prevalence of obesity has reached epidemic levels in many parts of the world; more than 1 billion adults are overweight with a body mass index (BMI) exceeding 25. Overweight and obesity are clinically defined indicators of a disease process characterized by the accumulation of body fat due to an excess of energy intake (nutritional intake) relative to energy expenditure (physical activity). When energy intake exceeds energy expenditure over a prolonged period of time, the result is a positive energy balance (PEB), which leads to the development of obesity. This physical state is ideal for intervention and can be modulated by changes in energy intake, expenditure, or both. Nutritional intake is a modifiable factor in the energy balance-cancer linkage primarily tested by caloric restriction studies in animals and the effect of energy availability. Restriction of calories by 10 to 40% has been shown to decrease cell proliferation, increasing apoptosis through anti-angiogenic processes. The potent anticancer effect of caloric restriction is clear, but caloric restriction alone is not generally considered to be a feasible strategy for cancer prevention in humans. Identification and development of preventive strategies that "mimic" the anticancer effects of low energy intake are desirable. The independent effect of energy intake on cancer risk has been difficult to estimate because body size and physical activity are strong determinants of total energy expenditure. The mechanisms that account for the inhibitory effects of physical activity on the carcinogenic process

  9. Study to determine the criterion validity of the SenseWear Armband as a measure of physical activity in people with rheumatoid arthritis.

    PubMed

    Tierney, Marie; Fraser, Alexander; Purtill, Helen; Kennedy, Norelee

    2013-06-01

    Measuring physical activity in people with rheumatoid arthritis (RA) is of great importance in light of the increased mortality in this population due to cardiovascular disease. Validation of activity monitors in specific populations is recommended to ensure the accuracy of physical activity measurement. Thus, the purpose of this study was to determine the validity of the SenseWear Pro3 Armband (SWA) as a measure of physical activity during activities of daily living (ADL) in people with RA. Fourteen subjects (8 men and 6 women) with a diagnosis of RA were recruited from rheumatology clinics at the Mid-Western Regional Hospitals, Limerick, Ireland. Participants undertook a series of ADL of varying intensities. The SWA was compared to the criterion measures of the Oxycon Mobile indirect calorimetry system (energy expenditure in kJ) and of manual video observation (step count). Bland and Altman, intraclass correlation coefficient (ICC), and correlation analyses were done using SPSS, version 19.0. The SWA showed substantial agreement (ICC 0.717, P < 0.001) and a strong relationship (Pearson's correlation coefficient = 0.852) compared with the criterion measure when estimating energy expenditure during ADL. However, it was found that the SWA overestimated energy expenditure, particularly at higher intensity levels. The ability of the SWA to estimate step counts during ADL was poor (ICC 0.304, P = 0.038). The SWA can be considered a valid tool to estimate energy expenditure during ADL in the RA population; however, attention should be paid to its tendency to overestimate energy expenditure. Copyright © 2013 by the American College of Rheumatology.

  10. The Effects of Acid Etching on the Nanomorphological Surface Characteristics and Activation Energy of Titanium Medical Materials.

    PubMed

    Hung, Kuo-Yung; Lin, Yi-Chih; Feng, Hui-Ping

    2017-10-11

    The purpose of this study was to characterize the etching mechanism, namely, the etching rate and the activation energy, of a titanium dental implant in concentrated acid and to construct the relation between the activation energy and the nanoscale surface topographies. A commercially-pure titanium (CP Ti) and Ti-6Al-4V ELI surface were tested by shot blasting (pressure, grain size, blasting distance, blasting angle, and time) and acid etching to study its topographical, weight loss, surface roughness, and activation energy. An Arrhenius equation was applied to derive the activation energy for the dissolution of CP Ti/Ti-6Al-4V ELI in sulfuric acid (H₂SO₄) and hydrochloric acid (HCl) at different temperatures. In addition, white-light interferometry was applied to measure the surface nanomorphology of the implant to obtain 2D or 3D roughness parameters (Sa, Sq, and St). The nanopore size that formed after etching was approximately 100-500 nm. The surface roughness of CP Ti and Ti-6Al-4V ELI decreased as the activation energy decreased but weight loss increased. Ti-6Al-4V ELI has a higher level of activation energy than Ti in HCl, which results in lower surface roughness after acid etching. This study also indicates that etching using a concentrated hydrochloric acid provided superior surface modification effects in titanium compared with H₂SO₄.

  11. Development of departmental standard for traceability of measured activity for I-131 therapy capsules used in nuclear medicine.

    PubMed

    Ravichandran, Ramamoorthy; Binukumar, Jp

    2011-01-01

    International Basic Safety Standards (International Atomic Energy Agency, IAEA) provide guidance levels for diagnostic procedures in nuclear medicine indicating the maximum usual activity for various diagnostic tests in terms of activities of injected radioactive formulations. An accuracy of ± 10% in the activities of administered radio-pharmaceuticals is being recommended, for expected outcome in diagnostic and therapeutic nuclear medicine procedures. It is recommended that the long-term stability of isotope calibrators used in nuclear medicine is to be checked periodically for their performance using a long-lived check source, such as Cs-137, of suitable activity. In view of the un-availability of such a radioactive source, we tried to develop methods to maintain traceability of these instruments, for certifying measured activities for human use. Two re-entrant chambers [(HDR 1000 and Selectron Source Dosimetry System (SSDS)] with I-125 and Ir-192 calibration factors in the Department of Radiotherapy were used to measure Iodine-131 (I-131) therapy capsules to establish traceability to Mark V isotope calibrator of the Department of Nuclear Medicine. Special nylon jigs were fabricated to keep I-131 capsule holder in position. Measured activities in all the chambers showed good agreement. The accuracy of SSDS chamber in measuring Ir-192 activities in the last 5 years was within 0.5%, validating its role as departmental standard for measuring activity. The above method is adopted because mean energies of I-131 and Ir-192 are comparable.

  12. Accuracy of Consumer Monitors for Estimating Energy Expenditure and Activity Type.

    PubMed

    Woodman, James A; Crouter, Scott E; Bassett, David R; Fitzhugh, Eugene C; Boyer, William R

    2017-02-01

    Increasing use of consumer-based physical activity (PA) monitors necessitates that they are validated against criterion measures. Thus, the purpose of this study was to examine the accuracy of three consumer-based PA monitors for estimating energy expenditure (EE) and PA type during simulated free-living activities. Twenty-eight participants (mean ± SD: age, 25.5 ± 3.7 yr; body mass index, 24.9 ± 2.6 kg·m) completed 11 activities ranging from sedentary behaviors to vigorous intensities. Simultaneous measurements were made with an Oxycon portable calorimeter (criterion), a Basis Peak and Garmin Vivofit on the nondominant wrist, and three Withings Pulse devices (right hip, shirt collar, dominant wrist). Repeated-measures ANOVA were used to examine differences between measured and predicted EE. Intraclass correlation coefficients were calculated to determine reliability of EE predictions between Withings placements. Paired samples t tests were used to determine mean differences between observed minutes and Basis Peak predictions during walking, running, and cycling. On average, the Basis Peak was within 8% of measured EE for the entire PA routine (P > 0.05); however, there were large individual errors (95% prediction interval, -290.4 to +233.1 kcal). All other devices were significantly different from measured EE for the entire PA routine (P < 0.05). For activity types, Basis Peak correctly identified ≥92% of actual minutes spent walking and running (P > 0.05), and 40.4% and 0% of overground and stationary cycling minutes, respectively (P < 0.001). The Basis Peak was the only device that did not significantly differ from measured EE; however, it also had the largest individual errors. Additionally, the Basis Peak accurately predicted minutes spent walking and running, but not cycling.

  13. The Energy Measure for the Euler and Navier-Stokes Equations

    NASA Astrophysics Data System (ADS)

    Leslie, Trevor M.; Shvydkoy, Roman

    2018-04-01

    The potential failure of energy equality for a solution u of the Euler or Navier-Stokes equations can be quantified using a so-called `energy measure': the weak-* limit of the measures {|u(t)|^2dx} as t approaches the first possible blowup time. We show that membership of u in certain (weak or strong) {L^q L^p} classes gives a uniform lower bound on the lower local dimension of E ; more precisely, it implies uniform boundedness of a certain upper s-density of E . We also define and give lower bounds on the `concentration dimension' associated to E , which is the Hausdorff dimension of the smallest set on which energy can concentrate. Both the lower local dimension and the concentration dimension of E measure the departure from energy equality. As an application of our estimates, we prove that any solution to the 3-dimensional Navier-Stokes Equations which is Type-I in time must satisfy the energy equality at the first blowup time.

  14. Physical activity levels from a meta-analysis of doubly labeled water studies for validating energy intake as measured by dietary assessment.

    PubMed

    Black, A E

    1996-06-01

    Studies using doubly labeled water have identified underreporting of food intake as a problem of dietary surveys. However, reported energy intakes may be evaluated by comparison with energy requirements expressed as multiples of the basal metabolic rate, and a formula for calculating the value below which reported intake cannot be either a valid measure of habitual intake or a true low intake obtained by chance is presented. The energy requirements of different age-sex groups needed for the comparison with energy intakes have been obtained from a meta-analysis of doubly labeled water data.

  15. Limits on an energy dependence of the speed of light from a flare of the active galaxy PKS 2155-304.

    PubMed

    Aharonian, F; Akhperjanian, A G; Barres de Almeida, U; Bazer-Bachi, A R; Becherini, Y; Behera, B; Beilicke, M; Benbow, W; Bernlöhr, K; Boisson, C; Bochow, A; Borrel, V; Braun, I; Brion, E; Brucker, J; Brun, P; Bühler, R; Bulik, T; Büsching, I; Boutelier, T; Carrigan, S; Chadwick, P M; Charbonnier, A; Chaves, R C G; Chounet, L-M; Clapson, A C; Coignet, G; Costamante, L; Dalton, M; Degrange, B; Deil, C; Dickinson, H J; Djannati-Ataï, A; Domainko, W; Drury, L O'C; Dubois, F; Dubus, G; Dyks, J; Egberts, K; Emmanoulopoulos, D; Espigat, P; Farnier, C; Feinstein, F; Fiasson, A; Förster, A; Fontaine, G; Füssling, M; Gabici, S; Gallant, Y A; Gérard, L; Giebels, B; Glicenstein, J F; Glück, B; Goret, P; Hadjichristidis, C; Hauser, D; Hauser, M; Heinz, S; Heinzelmann, G; Henri, G; Hermann, G; Hinton, J A; Hoffmann, A; Hofmann, W; Holleran, M; Hoppe, S; Horns, D; Jacholkowska, A; de Jager, O C; Jung, I; Katarzyński, K; Kaufmann, S; Kendziorra, E; Kerschhaggl, M; Khangulyan, D; Khélifi, B; Keogh, D; Komin, Nu; Kosack, K; Lamanna, G; Lenain, J-P; Lohse, T; Marandon, V; Martin, J M; Martineau-Huynh, O; Marcowith, A; Maurin, D; McComb, T J L; Medina, C; Moderski, R; Moulin, E; Naumann-Godo, M; de Naurois, M; Nedbal, D; Nekrassov, D; Niemiec, J; Nolan, S J; Ohm, S; Olive, J-F; de Oña Wilhelmi, E; Orford, K J; Osborne, J L; Ostrowski, M; Panter, M; Pedaletti, G; Pelletier, G; Petrucci, P-O; Pita, S; Pühlhofer, G; Punch, M; Quirrenbach, A; Raubenheimer, B C; Raue, M; Rayner, S M; Renaud, M; Rieger, F; Ripken, J; Rob, L; Rosier-Lees, S; Rowell, G; Rudak, B; Ruppel, J; Sahakian, V; Santangelo, A; Schlickeiser, R; Schöck, F M; Schröder, R; Schwanke, U; Schwarzburg, S; Schwemmer, S; Shalchi, A; Skilton, J L; Sol, H; Spangler, D; Stawarz, Ł; Steenkamp, R; Stegmann, C; Superina, G; Tam, P H; Tavernet, J-P; Terrier, R; Tibolla, O; van Eldik, C; Vasileiadis, G; Venter, C; Vialle, J P; Vincent, P; Vivier, M; Völk, H J; Volpe, F; Wagner, S J; Ward, M; Zdziarski, A A; Zech, A

    2008-10-24

    In the past few decades, several models have predicted an energy dependence of the speed of light in the context of quantum gravity. For cosmological sources such as active galaxies, this minuscule effect can add up to measurable photon-energy dependent time lags. In this Letter a search for such time lags during the High Energy Stereoscopic System observations of the exceptional very high energy flare of the active galaxy PKS 2155-304 on 28 July 2006 is presented. Since no significant time lag is found, lower limits on the energy scale of speed of light modifications are derived.

  16. Smart approaches for assessing free-living energy expenditure following identification of types of physical activity.

    PubMed

    Plasqui, G

    2017-02-01

    Accurate assessment of physical activity and energy expenditure has been a research focus for many decades. A variety of wearable sensors have been developed to objectively capture physical activity patterns in daily life. These sensors have evolved from simple pedometers to tri-axial accelerometers, and multi sensor devices measuring different physiological constructs. The current review focuses on how activity recognition may help to improve daily life energy expenditure assessment. A brief overview is given about how different sensors have evolved over time to pave the way for recognition of different activity types. Once the activity is recognized together with the intensity of the activity, an energetic value can be attributed. This concept can then be tested in daily life using the independent reference technique doubly labeled water. So far, many studies have been performed to accurately identify activity types, and some of those studies have also successfully translated this into energy expenditure estimates. Most of these studies have been performed under standardized conditions, and the true applicability in daily life has rarely been addressed. The results so far however are highly promising, and technological advancements together with newly developed algorithms based on physiological constructs will further expand this field of research. © 2017 World Obesity Federation.

  17. Total photoproduction cross section measurement at HERA energies

    NASA Astrophysics Data System (ADS)

    Ahmed, T.; Andreev, V.; Andrieu, B.; Arpagaus, M.; Babaev, A.; Bärwolff, H.; Bán, J.; Baranov, P.; Barrelet, E.; Bartel, W.; Bassler, U.; Beck, G. A.; Beck, H. P.; Behrend, H.-J.; Belousov, A.; Berger, Ch.; Bergstein, H.; Bernardi, G.; Bernet, R.; Berthon, U.; Bertrand-Coremans, G.; Besançon, M.; Biddulph, P.; Binder, E.; Bizot, J. C.; Blobel, V.; Borras, K.; Bosetti, P. C.; Boudry, V.; Bourdarios, C.; Brasse, F.; Braun, U.; Braunschweig, W.; Brisson, V.; Bruncko, D.; Bürger, J.; Büsser, F. W.; Buniatian, A.; Burke, S.; Buschhorn, G.; Campbell, A. J.; Carli, T.; Charles, F.; Clarke, D.; Clegg, A. B.; Colombo, M.; Coughlan, J. A.; Courau, A.; Coutures, Ch.; Cozzika, G.; Criegee, L.; Cvach, J.; Dainton, J. B.; Danilov, M.; Dann, A. W. E.; Dau, W. D.; David, M.; Deffur, E.; Delcourt, B.; del Buono, L.; Devel, M.; de Roeck, A.; Dingus, P.; Dollfus, C.; Dowell, J. D.; Dreis, H. B.; Drescher, A.; Duboc, J.; Düllmann, D.; Dünger, O.; Duhm, H.; Eberle, M.; Ebert, J.; Ebert, T. R.; Eckerlin, G.; Efremenko, V.; Egli, S.; Eichenberger, S.; Eichler, R.; Eisele, F.; Eisenhandler, E.; Ellis, N. N.; Ellison, R. J.; Elsen, E.; Erdmann, M.; Evrard, E.; Favart, L.; Fedotov, A.; Feeken, D.; Felst, R.; Feltesse, J.; Feng, Y.; Fensome, I. F.; Ferencei, J.; Ferrarotto, F.; Flauger, W.; Fleischer, M.; Flower, P. S.; Flügge, G.; Fomenko, A.; Fominykh, B.; Forbush, M.; Formánek, J.; Foster, J. M.; Franke, G.; Fretwurst, E.; Fuhrmann, P.; Gabathuler, E.; Gamerdinger, K.; Garvey, J.; Gayler, J.; Gellrich, A.; Gennis, M.; Gensch, U.; Genzel, H.; Gerhards, R.; Gillespie, D.; Godfrey, L.; Goerlach, U.; Goerlich, L.; Goldberg, M.; Goodall, A. M.; Gorelov, I.; Goritchev, P.; Grab, C.; Grässler, H.; Grässler, R.; Greenshaw, T.; Greif, H.; Grindhammer, G.; Gruber, C.; Haack, J.; Haidt, D.; Hajduk, L.; Hamon, O.; Handschuh, D.; Hanlon, E. M.; Hapke, M.; Harjes, J.; Hartz, P.; Haydar, R.; Haynes, W. J.; Heatherington, J.; Hedberg, V.; Hedgecock, R.; Heinzelmann, G.; Henderson, R. C. W.; Henschel, H.; Herma, R.; Herynek, I.; Hildesheim, W.; Hill, P.; Hilton, C. D.; Hladký, J.; Hoeger, K. C.; Huet, Ph.; Hufnagel, H.; Huot, N.; Ibbotson, M.; Jabiol, M. A.; Jacholkowska, A.; Jacobsson, C.; Jaffre, M.; Jönsson, L.; Johannsen, K.; Johnson, D. P.; Johnson, L.; Jung, H.; Kalmus, P. I. P.; Kasarian, S.; Kaschowitz, R.; Kasselmann, P.; Kathage, U.; Kaufmann, H. H.; Kenyon, I. R.; Kermiche, S.; Kiesling, C.; Klein, M.; Kleinwort, C.; Knies, G.; Köhler, T.; Kolanoski, H.; Kole, F.; Kolya, S. D.; Korbel, V.; Korn, M.; Kostka, P.; Kotelnikov, S. K.; Krasny, M. W.; Krehbiel, H.; Krücker, D.; Krüger, U.; Kubenka, J. P.; Küster, H.; Kuhlen, M.; Kurça, T.; Kurzhöfer, J.; Kuznik, B.; Lander, R.; Landon, M. P. J.; Langkau, R.; Lanius, P.; Laporte, J. F.; Lebedev, A.; Leuschner, A.; Leverenz, C.; Levin, D.; Levonian, S.; Ley, Ch.; Lindner, A.; Lindström, G.; Loch, P.; Lohmander, H.; Lopez, G. C.; Lüers, D.; Magnussen, N.; Malinovski, E.; Mani, S.; Marage, P.; Marks, J.; Marshall, R.; Martens, J.; Martin, R.; Martyn, H.-U.; Martyniak, J.; Masson, S.; Mavroidis, A.; Maxfield, S. J.; McMahon, S. J.; Mehta, A.; Meier, K.; Merz, T.; Meyer, C. A.; Meyer, H.; Meyer, J.; Mikocki, S.; Milone, V.; Monnier, E.; Moreau, F.; Moreels, J.; Morris, J. V.; Morton, J. M.; Müller, K.; Murín, P.; Murray, S. A.; Nagovizin, V.; Naroska, B.; Naumann, Th.; Newton, D.; Nguyen, H. K.; Niebergall, F.; Nisius, R.; Nowak, G.; Noyes, G. W.; Nyberg, M.; Oberlack, H.; Obrock, H.; Olsson, J. E.; Orenstein, S.; Ould-Saada, F.; Pascaud, C.; Patel, G. D.; Peppel, E.; Peters, S.; Phillips, H. T.; Phillips, J. P.; Pichler, Ch.; Pilgram, W.; Pitzl, D.; Prosi, R.; Raupach, F.; Rauschnabel, K.; Reimer, P.; Ribarics, P.; Riech, V.; Riedlberger, J.; Rietz, M.; Robertson, S. M.; Robmann, P.; Roosen, R.; Rostovtsev, A.; Royon, C.; Rudowicz, M.; Ruffer, M.; Rusakov, S.; Rybicki, K.; Ryseck, E.; Sacton, J.; Sahlmann, N.; Sanchez, E.; Sankey, D. P. C.; Savitsky, M.; Schacht, P.; Schleper, P.; von Schlippe, W.; Schmidt, C.; Schmidt, D.; Schmitz, W.; Schröder, V.; Schulz, M.; Schwind, A.; Scobel, W.; Seehausen, U.; Sell, R.; Seman, M.; Semenov, A.; Shekelyan, V.; Sheviakov, I.; Shooshtari, H.; Siegmon, G.; Siewert, U.; Sirois, Y.; Skillicorn, I. O.; Smirnov, P.; Smith, J. R.; Smolik, L.; Soloviev, Y.; Spitzer, H.; Staroba, P.; Steenbock, M.; Steffen, P.; Steinberg, R.; Steiner, H.; Stella, B.; Stephens, K.; Stier, J.; Strachota, J.; Straumann, U.; Struczinski, W.; Sutton, J. P.; Taylor, R. E.; Thompson, G.; Thompson, R. J.; Tichomirov, I.; Trenkel, C.; Truöl, P.; Tchernyshov, V.; Turnau, J.; Tutas, J.; Urban, L.; Usik, A.; Valkar, S.; Valkarova, A.; Vallee, C.; van Esch, P.; Vartapetian, A.; Vazdik, Y.; Vecko, M.; Verrecchia, P.; Vick, R.; Villet, G.; Vogel, E.; Wacker, K.; Walker, I. W.; Walther, A.; Weber, G.; Wegener, D.; Wegner, A.; Wellisch, H. P.; Willard, S.; Winde, M.; Winter, G.-G.; Wolff, Th.; Womersley, L. A.; Wright, A. E.; Wulff, N.; Yiou, T. P.; Áçek, J.; Závada, P.; Zeitnitz, C.; Ziaeepour, H.; Zimmer, M.; Zimmermann, W.; Zomer, F.

    1993-01-01

    We present first results on the total photoproduction cross section measurement with the H1 detector at HERA. The data were extracted from low Q2 collisions of 26.7 GeV electrons with 820 GeV protons. The γp total cross section has been measured by two independent methods in the γp center of mass energy range from 90 to 290 GeV. For an average center of mass energy of 195 GeV a value of σtot (γp) = 159 +/- 7 (stat.) +/- 20 (syst.) μb was obtained. Supported by the Swedish Natural Science Research Council.

  18. Biomass measurement from LANDSAT: Drought and energy applications

    NASA Technical Reports Server (NTRS)

    Maxwell, E. L.

    1981-01-01

    The theory supporting the use of vegetation indices derived from LANDSAT data for the direct measurement of biomass is reviewed. The use of multispectral data to measure biomass is a natural and viable application since the photosynthetic production of biomass gives vegetation its unique spectral properties. Vegetation indices also perform a normalization function which tends to make them insensitive to atmospheric and soil color variations. Optical and digital LANDSAT products are discussed relative to the use of vegetation indices to monitor drought impact. Based on results obtained in Colorado, operational use of LANDSAT to monitor drought is cost effective, practical and ready for implementation today. The direct measurement of biomass energy resources may also benefit from LANDSAT technology. Measurement of total biomass and annual primary production may be feasible. Identification of that component of biomass resources available for energy use will require other sources of information, however.

  19. Resource Evaluation and Energy Production Estimate for a Tidal Energy Conversion Installation using Acoustic Flow Measurements

    NASA Astrophysics Data System (ADS)

    Gagnon, Ian; Baldwin, Ken; Wosnik, Martin

    2015-11-01

    The ``Living Bridge'' project plans to install a tidal turbine at Memorial Bridge in the Piscataqua River at Portsmouth, NH. A spatio-temporal tidal energy resource assessment was performed using long term bottom-deployed Acoustic Doppler Current Profilers ADCP. Two locations were evaluated: at the planned deployment location and mid-channel. The goal was to determine the amount of available kinetic energy that can be converted into usable electrical energy on the bridge. Changes in available kinetic energy with ebb/flood and spring/neap tidal cycles and electrical energy demand were analyzed. A system model is used to calculate the net energy savings using various tidal generator and battery bank configurations. Differences in the tidal characteristics between the two measurement locations are highlighted. Different resource evaluation methodologies were also analyzed, e.g., using a representative ADCP ``bin'' vs. a more refined, turbine-geometry-specific methodology, and using static bin height vs. bin height that move w.r.t. the free surface throughout a tidal cycle (representative of a bottom-fixed or floating turbine deployment, respectively). ADCP operating frequencies and bin sizes affect the standard deviation of measurements, and measurement uncertainties are evaluated. Supported by NSF-IIP grant 1430260.

  20. Measurement of inequality using household energy consumption data in rural China

    NASA Astrophysics Data System (ADS)

    Wu, Shimei; Zheng, Xinye; Wei, Chu

    2017-10-01

    Measuring inequality can be challenging due to the limitations of using household income or expenditure data. Because actual energy consumption can be measured more easily and accurately and is relatively more stable, it may be a better measure of inequality. Here we use data on energy consumption for specific devices from a large nation-wide household survey (n = 3,404 rural households from 12 provinces) to assess inequality in rural China. We find that the overall inequality of energy consumption and expenditure varies greatly in terms of energy type, end-use demand, regions and climatic zones. Biomass, space heating and cooking, intraregional differences, and climatic zones characterized as cold or hot summer/cold winter contribute the most to total inequality for each indicator, respectively. The results suggest that the expansion of infrastructure does not accompany alleviation of energy inequality, and that energy affordability should be improved through income growth and targeted safety-net programmes instead of energy subsidies.

  1. Proton and deuteron activation measurements at the NPI and future plans in SPIRAL2/NFS

    NASA Astrophysics Data System (ADS)

    Šimečková, Eva; Bém, Pavel; Mrázek, Jaromír; Štefánik, Milan; Běhal, Radomír; Gladolev, Vadim

    2017-09-01

    The proton- and deuteron-induced reactions are of a great interest for the assessment of induced radioactivity of accelerator components, target and beam stoppers as well as isotope production for medicine. In the present work, the deuteron-induced reaction cross sections on zinc were investigated by stacked-foil activation technique with deuteron beam of 20 MeV energy from the cyclotron U-120M of NPI CAS Řež. Also the proton activation cross section measurement of iron is presented. The comparison of present results to data of other authors and to predictions of evaluated data libraries is discussed. The investigation shall continue for higher proton and deuteron energy interval 20-35 MeV at SPIRAL2/NFS facility using a charged particle irradiation chamber with pneumatic transport system to measure isotopes and isomers with half-lives in minutes-regions.

  2. Hermes III endpoint energy calculation from photonuclear activation of 197Au and 58Ni foils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parzyck, Christopher Thomas

    2014-09-01

    A new process has been developed to characterize the endpoint energy of HERMES III on a shot-to-shot basis using standard dosimetry tools from the Sandia Radiation Measurements Laboratory. Photonuclear activation readings from nickel and gold foils are used in conjunction with calcium fluoride thermoluminescent dosimeters to derive estimated electron endpoint energies for a series of HERMES shots. The results are reasonably consistent with the expected endpoint voltages on those shots.

  3. On Measuring Cosmic Ray Energy Spectra with the Rapidity Distributions

    NASA Technical Reports Server (NTRS)

    Bashindzhagyan, G.; Adams, J.; Chilingarian, A.; Drury, L.; Egorov, N.; Golubkov, S.; Korotkova, N.; Panasyuk, M.; Podorozhnyi, D.; Procqureur, J.

    2000-01-01

    An important goal of cosmic ray research is to measure the elemental energy spectra of galactic cosmic rays up to 10(exp 16) eV. This goal cannot be achieved with an ionization calorimeter because the required instrument is too massive for space flight. An alternate method will be presented. This method is based on measuring the primary particle energy by determining the angular distribution of secondaries produced in a target layer. The proposed technique can be used over a wide range of energies (10 (exp 11) -10 (exp 16) eV) and gives an energy resolution of 60% or better. Based on this technique, a conceptual design for a new instrument (KLEM) will be presented. Due to its light weight, this instrument can have a large aperture enabling the direct measurement of cosmic rays to 1016 eV.

  4. Activity Profile and Energy Expenditure Among Active Older Adults, British Columbia, 2011-2012.

    PubMed

    Madden, Kenneth M; Ashe, Maureen C; Chase, Jocelyn M

    2015-07-16

    Time spent by young adults in moderate to vigorous activity predicts daily caloric expenditure. In contrast, caloric expenditure among older adults is best predicted by time spent in light activity. We examined highly active older adults to examine the biggest contributors to energy expenditure in this population. Fifty-four community-dwelling men and women aged 65 years or older (mean, 71.4 y) were enrolled in this cross-sectional observational study. All were members of the Whistler Senior Ski Team, and all met current American guidelines for physical activity. Activity levels (sedentary, light, and moderate to vigorous) were recorded by accelerometers worn continuously for 7 days. Caloric expenditure was measured using accelerometry, galvanic skin response, skin temperature, and heat flux. Significant variables were entered into a stepwise multivariate linear model consisting of activity level, age, and sex. The average (standard deviation [SD]) daily nonlying sedentary time was 564 (92) minutes (9.4 [1.5] h) per day. The main predictors of higher caloric expenditure were time spent in moderate to vigorous activity (standardized β = 0.42 [SE, 0.08]; P < .001) and male sex (standardized β = 1.34 [SE, 0.16]; P < .001). A model consisting of only moderate to vigorous physical activity and sex explained 68% of the variation in caloric expenditure. An increase in moderate to vigorous physical activity by 1 minute per day was associated with an additional 16 kcal expended in physical activity. The relationship between activity intensity and caloric expenditure in athletic seniors is similar to that observed in young adults. Active older adults still spend a substantial proportion of the day engaged in sedentary behaviors.

  5. Physical Modeling of Activation Energy in Organic Semiconductor Devices based on Energy and Momentum Conservations

    PubMed Central

    Mao, Ling-Feng; Ning, H.; Hu, Changjun; Lu, Zhaolin; Wang, Gaofeng

    2016-01-01

    Field effect mobility in an organic device is determined by the activation energy. A new physical model of the activation energy is proposed by virtue of the energy and momentum conservation equations. The dependencies of the activation energy on the gate voltage and the drain voltage, which were observed in the experiments in the previous independent literature, can be well explained using the proposed model. Moreover, the expression in the proposed model, which has clear physical meanings in all parameters, can have the same mathematical form as the well-known Meyer-Neldel relation, which lacks of clear physical meanings in some of its parameters since it is a phenomenological model. Thus it not only describes a physical mechanism but also offers a possibility to design the next generation of high-performance optoelectronics and integrated flexible circuits by optimizing device physical parameter. PMID:27103586

  6. NREL Open House Features Energy Activities, Tours

    Science.gov Websites

    Open House Features Energy Activities, Tours For more information contact: e:mail: Public Affairs National Renewable Energy Laboratory (NREL) will open its doors 10 a.m. to 3 p.m., Saturday, July 24 for tours of its research facilities and interactive exhibits at the Visitors Center. The Open House

  7. A time to search: finding the meaning of variable activation energy.

    PubMed

    Vyazovkin, Sergey

    2016-07-28

    This review deals with the phenomenon of variable activation energy frequently observed when studying the kinetics in the liquid or solid phase. This phenomenon commonly manifests itself through nonlinear Arrhenius plots or dependencies of the activation energy on conversion computed by isoconversional methods. Variable activation energy signifies a multi-step process and has a meaning of a collective parameter linked to the activation energies of individual steps. It is demonstrated that by using appropriate models of the processes, the link can be established in algebraic form. This allows one to analyze experimentally observed dependencies of the activation energy in a quantitative fashion and, as a result, to obtain activation energies of individual steps, to evaluate and predict other important parameters of the process, and generally to gain deeper kinetic and mechanistic insights. This review provides multiple examples of such analysis as applied to the processes of crosslinking polymerization, crystallization and melting of polymers, gelation, and solid-solid morphological and glass transitions. The use of appropriate computational techniques is discussed as well.

  8. Simulation and experimental measurement of radon activity using a multichannel silicon-based radiation detector.

    PubMed

    Ozdemir, F B; Selcuk, A B; Ozkorucuklu, S; Alpat, A B; Ozdemir, T; Ӧzek, N

    2018-05-01

    In this study, high-precision radiation detector (HIPRAD), a new-generation semiconductor microstrip detector, was used for detecting radon (Rn-222) activity. The aim of this study was to detect radon (Rn-222) activity experimentally by measuring the energy of particles in this detector. Count-ADC channel, eta-charge, and dose-response values were experimentally obtained using HIPRAD. The radon simulation in the radiation detector was theoretically performed using the Geant4 software package. The obtained radioactive decay, energy generation, energy values, and efficiency values of the simulation were plotted using the root program. The new-generation radiation detector proved to have 95% reliability according to the obtained dose-response graphs. The experimental and simulation results were found to be compatible with each other and with the radon decays and literature studies. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Energy Efficiency in Gait, Activity, Participation, and Health Status in Children with Cerebral Palsy

    ERIC Educational Resources Information Center

    Kerr, Claire; Parkes, Jackie; Stevenson, Mike; Cosgrove, Aidan P.; McDowell, Brona C.

    2008-01-01

    The aim of the study was to establish if a relationship exists between the energy efficiency of gait, and measures of activity limitation, participation restriction, and health status in a representative sample of children with cerebral palsy (CP). Secondary aims were to investigate potential differences between clinical subtypes and gross motor…

  10. Single Molecule Measurements of Interaction Free Energies Between the Proteins Within Binary and Ternary SNARE Complexes

    PubMed Central

    Liu, W.; Montana, Vedrana; Parpura, Vladimir; Mohideen, U.

    2010-01-01

    We use an Atomic Force Microscope based single molecule measurements to evaluate the activation free energy in the interaction of SNARE proteins syntaxin 1A, SNAP25B and synaptobrevin 2 which regulate intracellular fusion of vesicles with target membranes. The dissociation rate of the binary syntaxin-synaptobrevin and the ternary syntaxin-SNAP25B-synaptobrevin complex was measured from the rupture force distribution as a function of the rate of applied force. The temperature dependence of the spontaneous dissociation rate was used to obtain the activation energy to the transition state of 19.8 ± 3.5 kcal/mol = 33 ± 6 kBT and 25.7 ± 3.0 kcal/mol = 43 ± 5 kBT for the binary and ternary complex, respectively. They are consistent with those measured previously for the ternary complex in lipid membranes and are of order expected for bilayer fusion and pore formation. The ΔG was 12.4–16.6 kcal/mol = 21–28 kBT and 13.8–18.0 kcal/mol = 23–30 kBT for the binary and ternary complex, respectively. The ternary complex was more stable by 1.4 kcal/mol = 2.3 kBT, consistent with the spontaneous dissociation rates. The higher adhesion energies and smaller molecular extensions measured with SNAP25B point to its possible unique and important physiological role in tethering/docking the vesicle in closer proximity to the plasma membrane and increasing the probability for fusion completion. PMID:20107522

  11. Ventromedial hypothalamic melanocortin receptor activation: regulation of activity energy expenditure and skeletal muscle thermogenesis.

    PubMed

    Gavini, Chaitanya K; Jones, William C; Novak, Colleen M

    2016-09-15

    The ventromedial hypothalamus (VMH) and the central melanocortin system both play vital roles in regulating energy balance by modulating energy intake and utilization. Recent evidence suggests that activation of the VMH alters skeletal muscle metabolism. We show that intra-VMH melanocortin receptor activation increases energy expenditure and physical activity, switches fuel utilization to fats, and lowers work efficiency such that excess calories are dissipated by skeletal muscle as heat. We also show that intra-VMH melanocortin receptor activation increases sympathetic nervous system outflow to skeletal muscle. Intra-VMH melanocortin receptor activation also induced significant changes in the expression of mediators of energy expenditure in muscle. These results support the role of melanocortin receptors in the VMH in the modulation of skeletal muscle metabolism. The ventromedial hypothalamus (VMH) and the brain melanocortin system both play vital roles in increasing energy expenditure (EE) and physical activity, decreasing appetite and modulating sympathetic nervous system (SNS) outflow. Because of recent evidence showing that VMH activation modulates skeletal muscle metabolism, we propose the existence of an axis between the VMH and skeletal muscle, modulated by brain melanocortins, modelled on the brain control of brown adipose tissue. Activation of melanocortin receptors in the VMH of rats using a non-specific agonist melanotan II (MTII), compared to vehicle, increased oxygen consumption and EE and decreased the respiratory exchange ratio. Intra-VMH MTII enhanced activity-related EE even when activity levels were held constant. MTII treatment increased gastrocnemius muscle heat dissipation during controlled activity, as well as in the home cage. Compared to vehicle-treated rats, rats with intra-VMH melanocortin receptor activation had higher skeletal muscle norepinephrine turnover, indicating an increased SNS drive to muscle. Lastly, intra-VMH MTII induced m

  12. Accurate prediction of energy expenditure using a shoe-based activity monitor.

    PubMed

    Sazonova, Nadezhda; Browning, Raymond C; Sazonov, Edward

    2011-07-01

    The aim of this study was to develop and validate a method for predicting energy expenditure (EE) using a footwear-based system with integrated accelerometer and pressure sensors. We developed a footwear-based device with an embedded accelerometer and insole pressure sensors for the prediction of EE. The data from the device can be used to perform accurate recognition of major postures and activities and to estimate EE using the acceleration, pressure, and posture/activity classification information in a branched algorithm without the need for individual calibration. We measured EE via indirect calorimetry as 16 adults (body mass index=19-39 kg·m) performed various low- to moderate-intensity activities and compared measured versus predicted EE using several models based on the acceleration and pressure signals. Inclusion of pressure data resulted in better accuracy of EE prediction during static postures such as sitting and standing. The activity-based branched model that included predictors from accelerometer and pressure sensors (BACC-PS) achieved the lowest error (e.g., root mean squared error (RMSE)=0.69 METs) compared with the accelerometer-only-based branched model BACC (RMSE=0.77 METs) and nonbranched model (RMSE=0.94-0.99 METs). Comparison of EE prediction models using data from both legs versus models using data from a single leg indicates that only one shoe needs to be equipped with sensors. These results suggest that foot acceleration combined with insole pressure measurement, when used in an activity-specific branched model, can accurately estimate the EE associated with common daily postures and activities. The accuracy and unobtrusiveness of a footwear-based device may make it an effective physical activity monitoring tool.

  13. Measuring Energy Scaling of Laser Driven Magnetic Fields

    NASA Astrophysics Data System (ADS)

    Williams, Jackson; Goyon, Clement; Mariscal, Derek; Pollock, Brad; Patankar, Siddharth; Moody, John

    2016-10-01

    Laser-driven magnetic fields are of interest in particle confinement, fast ignition, and ICF platforms as an alternative to pulsed power systems to achieve many times higher fields. A comprehensive model describing the mechanism responsible for creating and maintaining magnetic fields from laser-driven coils has not yet been established. Understanding the scaling of key experimental parameters such as spatial and temporal uniformity and duration are necessary to implement coil targets in practical applications yet these measurements prove difficult due to the highly transient nature of the fields. We report on direct voltage measurements of laser-driven coil targets in which the laser energy spans more than four orders of magnitude. Results suggest that at low energies, laser-driven coils can be modeled as an electric circuit; however, at higher energies plasma effects dominate and a simple circuit treatment is insufficient to describe all observed phenomenon. The favorable scaling with laser power and pulse duration, observed in the present study and others at kilojoule energies, has positive implications for sustained, large magnetic fields for applications on the NIF. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  14. Strain energy storage and dissipation rate in active cell mechanics

    NASA Astrophysics Data System (ADS)

    Agosti, A.; Ambrosi, D.; Turzi, S.

    2018-05-01

    When living cells are observed at rest on a flat substrate, they can typically exhibit a rounded (symmetric) or an elongated (polarized) shape. Although the cells are apparently at rest, the active stress generated by the molecular motors continuously stretches and drifts the actin network, the cytoskeleton of the cell. In this paper we theoretically compare the energy stored and dissipated in this active system in two geometric configurations of interest: symmetric and polarized. We find that the stored energy is larger for a radially symmetric cell at low activation regime, while the polar configuration has larger strain energy when the active stress is beyond a critical threshold. Conversely, the dissipation of energy in a symmetric cell is always larger than that of a nonsymmetric one. By a combination of symmetry arguments and competition between surface and bulk stress, we argue that radial symmetry is an energetically expensive metastable state that provides access to an infinite number of lower-energy states, the polarized configurations.

  15. Strain energy storage and dissipation rate in active cell mechanics.

    PubMed

    Agosti, A; Ambrosi, D; Turzi, S

    2018-05-01

    When living cells are observed at rest on a flat substrate, they can typically exhibit a rounded (symmetric) or an elongated (polarized) shape. Although the cells are apparently at rest, the active stress generated by the molecular motors continuously stretches and drifts the actin network, the cytoskeleton of the cell. In this paper we theoretically compare the energy stored and dissipated in this active system in two geometric configurations of interest: symmetric and polarized. We find that the stored energy is larger for a radially symmetric cell at low activation regime, while the polar configuration has larger strain energy when the active stress is beyond a critical threshold. Conversely, the dissipation of energy in a symmetric cell is always larger than that of a nonsymmetric one. By a combination of symmetry arguments and competition between surface and bulk stress, we argue that radial symmetry is an energetically expensive metastable state that provides access to an infinite number of lower-energy states, the polarized configurations.

  16. Measurements of radiated elastic wave energy from dynamic tensile cracks

    NASA Technical Reports Server (NTRS)

    Boler, Frances M.

    1990-01-01

    The role of fracture-velocity, microstructure, and fracture-energy barriers in elastic wave radiation during a dynamic fracture was investigated in experiments in which dynamic tensile cracks of two fracture cofigurations of double cantilever beam geometry were propagating in glass samples. The first, referred to as primary fracture, consisted of fractures of intact glass specimens; the second configuration, referred to as secondary fracture, consisted of a refracture of primary fracture specimens which were rebonded with an intermittent pattern of adhesive to produce variations in fracture surface energy along the crack path. For primary fracture cases, measurable elastic waves were generated in 31 percent of the 16 fracture events observed; the condition for radiation of measurable waves appears to be a local abrupt change in the fracture path direction, such as occurs when the fracture intersects a surface flaw. For secondary fractures, 100 percent of events showed measurable elastic waves; in these fractures, the ratio of radiated elastic wave energy in the measured component to fracture surface energy was 10 times greater than for primary fracture.

  17. Biomass I. Science Activities in Energy [and] Teacher's Guide.

    ERIC Educational Resources Information Center

    Oak Ridge Associated Universities, TN.

    Designed for science students in fourth, fifth, and sixth grades, the activities in this unit illustrate principles and problems related to biomass as a form of energy. (The word biomass is used to describe all solid material of animal or vegetable origin from which energy may be extracted.) Twelve student activities using art, economics,…

  18. Low levels of physical activity are associated with dysregulation of energy intake and fat mass gain over 1 year.

    PubMed

    Shook, Robin P; Hand, Gregory A; Drenowatz, Clemens; Hebert, James R; Paluch, Amanda E; Blundell, John E; Hill, James O; Katzmarzyk, Peter T; Church, Timothy S; Blair, Steven N

    2015-12-01

    Previous studies suggest that appetite may be dysregulated at low levels of activity, creating an energy imbalance that results in weight gain. The aim was to examine the relation between energy intake, physical activity, appetite, and weight gain during a 1-y follow-up period in a large sample of adults. Participants included 421 individuals (mean ± SD age: 27.6 ± 3.8 y). Measurements included the following: energy intake with the use of interviewer-administered dietary recalls and calculated by using changes in body composition and energy expenditure, moderate-to-vigorous physical activity (MVPA) with the use of an arm-based monitor, body composition with the use of dual-energy X-ray absorptiometry, and questionnaire-derived perceptions of dietary restraint, disinhibition, hunger, and control of eating. Participants were grouped at baseline into quintiles of MVPA (min/d) by sex. Measurements were repeated every 3 mo for 1 y. At baseline, an inverse relation existed between body weight and activity groups, with the least-active group (15.7 ± 9.9 min MVPA/d, 6062 ± 1778 steps/d) having the highest body weight (86.3 ± 13.2 kg) and the most-active group (174.5 ± 60.5 min MVPA/d, 10260 ± 3087 steps/d) having the lowest body weight (67.5 ± 11.0 kg). A positive relation was observed between calculated energy intake and activity group, except in the lowest quintile of activity. The lowest physical activity group reported higher levels of disinhibition (P = 0.07) and cravings for savory foods (P = 0.03) compared with the group with the highest level of physical activity. Over 1 y of follow-up, the lowest activity group gained the largest amount of fat mass (1.7 ± 0.3 kg) after adjustment for change in MVPA and baseline fat mass. The odds of gaining >3% of fat mass were between 1.8 and 3.8 times as high for individuals in the least-active group as for those in the middle activity group. These results suggest that low levels of physical activity are a risk factor

  19. The Effects of Acid Etching on the Nanomorphological Surface Characteristics and Activation Energy of Titanium Medical Materials

    PubMed Central

    Hung, Kuo-Yung; Lin, Yi-Chih; Feng, Hui-Ping

    2017-01-01

    The purpose of this study was to characterize the etching mechanism, namely, the etching rate and the activation energy, of a titanium dental implant in concentrated acid and to construct the relation between the activation energy and the nanoscale surface topographies. A commercially-pure titanium (CP Ti) and Ti-6Al-4V ELI surface were tested by shot blasting (pressure, grain size, blasting distance, blasting angle, and time) and acid etching to study its topographical, weight loss, surface roughness, and activation energy. An Arrhenius equation was applied to derive the activation energy for the dissolution of CP Ti/Ti-6Al-4V ELI in sulfuric acid (H2SO4) and hydrochloric acid (HCl) at different temperatures. In addition, white-light interferometry was applied to measure the surface nanomorphology of the implant to obtain 2D or 3D roughness parameters (Sa, Sq, and St). The nanopore size that formed after etching was approximately 100–500 nm. The surface roughness of CP Ti and Ti-6Al-4V ELI decreased as the activation energy decreased but weight loss increased. Ti-6Al-4V ELI has a higher level of activation energy than Ti in HCl, which results in lower surface roughness after acid etching. This study also indicates that etching using a concentrated hydrochloric acid provided superior surface modification effects in titanium compared with H2SO4. PMID:29019926

  20. 40 CFR 73.81 - Qualified conservation measures and renewable energy generation.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... renewable energy generation. 73.81 Section 73.81 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) SULFUR DIOXIDE ALLOWANCE SYSTEM Energy Conservation and Renewable Energy Reserve § 73.81 Qualified conservation measures and renewable energy generation. (a) Qualified energy...

  1. 40 CFR 73.81 - Qualified conservation measures and renewable energy generation.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... renewable energy generation. 73.81 Section 73.81 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) SULFUR DIOXIDE ALLOWANCE SYSTEM Energy Conservation and Renewable Energy Reserve § 73.81 Qualified conservation measures and renewable energy generation. (a) Qualified energy...

  2. 40 CFR 73.81 - Qualified conservation measures and renewable energy generation.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... renewable energy generation. 73.81 Section 73.81 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) SULFUR DIOXIDE ALLOWANCE SYSTEM Energy Conservation and Renewable Energy Reserve § 73.81 Qualified conservation measures and renewable energy generation. (a) Qualified energy...

  3. Association of energy intake and physical activity with overweight among Indonesian children 6-12 years of age.

    PubMed

    Harahap, Heryudarini; Sandjaja, Sandjaja; Soekatri, Moesijanti; Khouw, Ilse; Deurenberg, Paul

    2018-01-01

    Indonesia is currently facing double burden malnutrition in children. As overweight and obesity are due to a disturbed energy balance, this study aimed to assess the association of total energy intake and physical activity with the prevalence of overweight among Indonesian children. The data used for this analysis were from 1143 children, 6-12 years old, that participated in the South East Asian Nutrition Survey (SEANUTS). Physical activity (PA) was measured using pedometers for 2 consecutive days and was categorized low, moderate and high. Child nutritional status was categorized based on body mass index for age z-scores (BAZ) into normal weight (-2 SD ≤BAZ≤1 SD) or overweight (BAZ >1 SD). Energy intake was calculated from a one day 24 hour recall and compared to the Indonesian recommended dietary allowance (RDA) for energy. Children with low PA had higher risk (ODDs 3.4, 95% CI: 2.0, 6.0) of being overweight compared to children who had high PA. Children with moderate PA and energy take >100% RDA had higher risk (ODDs 4.2, 95% CI 1.9, 9.3) of being overweight than children with high PA and energy intakes ≤100% RDA. Low physical activity independently or moderate physical activity and high energy intake are risk factors for Indonesian children to get overweight. Program intervention such as increasing physical activity at school and home is needed to reduce overweight among children.

  4. On-farm estimation of energy balance in dairy cows using only frequent body weight measurements and body condition score.

    PubMed

    Thorup, V M; Edwards, D; Friggens, N C

    2012-04-01

    Precise energy balance estimates for individual cows are of great importance to monitor health, reproduction, and feed management. Energy balance is usually calculated as energy input minus output (EB(inout)), requiring measurements of feed intake and energy output sources (milk, maintenance, activity, growth, and pregnancy). Except for milk yield, direct measurements of the other sources are difficult to obtain in practice, and estimates contain considerable error sources, limiting on-farm use. Alternatively, energy balance can be estimated from body reserve changes (EB(body)) using body weight (BW) and body condition score (BCS). Automated weighing systems exist and new technology performing semi-automated body condition scoring has emerged, so frequent automated BW and BCS measurements are feasible. We present a method to derive individual EB(body) estimates from frequently measured BW and BCS and evaluate the performance of the estimated EB(body) against the traditional EB(inout) method. From 76 Danish Holstein and Jersey cows, parity 1 or 2+, on a glycerol-rich or a whole grain-rich total mixed ration, BW was measured automatically at each milking. The BW was corrected for the weight of milk produced and for gutfill. Changes in BW and BCS were used to calculate changes in body protein, body lipid, and EB(body) during the first 150 d in milk. The EB(body) was compared with the traditional EB(inout) by isolating the term within EB(inout) associated with most uncertainty; that is, feed energy content (FEC); FEC=(EB(body)+EMilk+EMaintenance+Eactivity)/dry matter intake, where the energy requirements are for milk produced (EMilk), maintenance (EMaintenance), and activity (EActivity). Estimated FEC agreed well with FEC values derived from tables (the mean estimate was 0.21 MJ of effective energy/kg of dry matter or 2.2% higher than the mean table value). Further, the FEC profile did not suggest systematic bias in EB(body) with stage of lactation. The EB

  5. Activation of hip prostheses in high energy radiotherapy and resultant dose to nearby tissue.

    PubMed

    Keehan, Stephanie; Smith, Ryan L; Millar, Jeremy; Esser, Max; Taylor, Michael L; Lonski, Peta; Kron, Tomas; Franich, Rick D

    2017-03-01

    High energy radiotherapy can produce contaminant neutrons through the photonuclear effect. Patients receiving external beam radiation therapy to the pelvis may have high-density hip prostheses. Metallic materials such as those in hip prostheses, often have high cross-sections for neutron interaction. In this study, Thackray (UK) prosthetic hips have been irradiated by 18 MV radiotherapy beams to evaluate the additional dose to patients from the activation products. Hips were irradiated in- and out-of field at various distances from the beam isocenter to assess activation caused in-field by photo-activation, and neutron activation which occurs both in and out-of-field. NaI(Tl) scintillator detectors were used to measure the subsequent gamma-ray emissions and their half-lives. High sensitivity Mg, Cu, P doped LiF thermoluminescence dosimeter chips (TLD-100H) were used to measure the subsequent dose at the surface of a prosthesis over the 12 h following an in-field irradiation of 10,000 MU to a hip prosthesis located at the beam isocenter in a water phantom. 53 Fe, 56 Mn, and 52 V were identified within the hip following irradiation by radiotherapy beams. The dose measured at the surface of a prosthesis following irradiation in a water phantom was 0.20 mGy over 12 h. The dose at the surface of prostheses irradiated to 200 MU was below the limit of detection (0.05 mGy) of the TLD100H. Prosthetic hips are activated by incident photons and neutrons in high energy radiotherapy, however, the dose resulting from activation is very small. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  6. Stress versus temperature dependence of activation energies for creep

    NASA Technical Reports Server (NTRS)

    Freed, A. D.; Raj, S. V.; Walker, K. P.

    1992-01-01

    The activation energy for creep at low stresses and elevated temperatures is associated with lattice diffusion, where the rate controlling mechanism for deformation is dislocation climb. At higher stresses and intermediate temperatures, the rate controlling mechanism changes from dislocation climb to obstacle-controlled dislocation glide. Along with this change in deformation mechanism occurs a change in the activation energy. When the rate controlling mechanism for deformation is obstacle-controlled dislocation glide, it is shown that a temperature-dependent Gibbs free energy does better than a stress-dependent Gibbs free energy in correlating steady-state creep data for both copper and LiF-22mol percent CaF2 hypereutectic salt.

  7. Measurements of the atmospheric neutrino flux by Super-Kamiokande: Energy spectra, geomagnetic effects, and solar modulation

    NASA Astrophysics Data System (ADS)

    Richard, E.; Okumura, K.; Abe, K.; Haga, Y.; Hayato, Y.; Ikeda, M.; Iyogi, K.; Kameda, J.; Kishimoto, Y.; Miura, M.; Moriyama, S.; Nakahata, M.; Nakajima, T.; Nakano, Y.; Nakayama, S.; Orii, A.; Sekiya, H.; Shiozawa, M.; Takeda, A.; Tanaka, H.; Tomura, T.; Wendell, R. A.; Akutsu, R.; Irvine, T.; Kajita, T.; Kaneyuki, K.; Nishimura, Y.; Labarga, L.; Fernandez, P.; Gustafson, J.; Kachulis, C.; Kearns, E.; Raaf, J. L.; Stone, J. L.; Sulak, L. R.; Berkman, S.; Nantais, C. M.; Tanaka, H. A.; Tobayama, S.; Goldhaber, M.; Kropp, W. R.; Mine, S.; Weatherly, P.; Smy, M. B.; Sobel, H. W.; Takhistov, V.; Ganezer, K. S.; Hartfiel, B. L.; Hill, J.; Hong, N.; Kim, J. Y.; Lim, I. T.; Park, R. G.; Himmel, A.; Li, Z.; O'Sullivan, E.; Scholberg, K.; Walter, C. W.; Wongjirad, T.; Ishizuka, T.; Tasaka, S.; Jang, J. S.; Learned, J. G.; Matsuno, S.; Smith, S. N.; Friend, M.; Hasegawa, T.; Ishida, T.; Ishii, T.; Kobayashi, T.; Nakadaira, T.; Nakamura, K.; Oyama, Y.; Sakashita, K.; Sekiguchi, T.; Tsukamoto, T.; Suzuki, A. T.; Takeuchi, Y.; Yano, T.; Cao, S. V.; Hiraki, T.; Hirota, S.; Huang, K.; Kikawa, T.; Minamino, A.; Nakaya, T.; Suzuki, K.; Fukuda, Y.; Choi, K.; Itow, Y.; Suzuki, T.; Mijakowski, P.; Frankiewicz, K.; Hignight, J.; Imber, J.; Jung, C. K.; Li, X.; Palomino, J. L.; Wilking, M. J.; Yanagisawa, C.; Fukuda, D.; Ishino, H.; Kayano, T.; Kibayashi, A.; Koshio, Y.; Mori, T.; Sakuda, M.; Xu, C.; Kuno, Y.; Tacik, R.; Kim, S. B.; Okazawa, H.; Choi, Y.; Nishijima, K.; Koshiba, M.; Totsuka, Y.; Suda, Y.; Yokoyama, M.; Bronner, C.; Hartz, M.; Martens, K.; Marti, Ll.; Suzuki, Y.; Vagins, M. R.; Martin, J. F.; Konaka, A.; Chen, S.; Zhang, Y.; Wilkes, R. J.; Super-Kamiokande Collaboration

    2016-09-01

    A comprehensive study of the atmospheric neutrino flux in the energy region from sub-GeV up to several TeV using the Super-Kamiokande (SK) water Cherenkov detector is presented in this paper. The energy and azimuthal spectra, and variation over time, of the atmospheric νe+ν¯ e and νμ+ν¯μ fluxes are measured. The energy spectra are obtained using an iterative unfolding method by combining various event topologies with differing energy responses. The azimuthal spectra depending on energy and zenith angle, and their modulation by geomagnetic effects, are also studied. A predicted east-west asymmetry is observed in both the νe and νμ samples at 8.0 σ and 6.0 σ significance, respectively, and an indication that the asymmetry dipole angle changes depending on the zenith angle was seen at the 2.2 σ level. The measured energy and azimuthal spectra are consistent with the current flux models within the estimated systematic uncertainties. A study of the long-term correlation between the atmospheric neutrino flux and the solar magnetic activity cycle is performed, and a weak preference for a correlation was seen at the 1.1 σ level, using SK-I-SK-IV data spanning a 20-year period. For several particularly strong solar activity periods, corresponding to Forbush decrease events, no theoretical prediction is available but a deviation below the typical neutrino event rate is seen at the 2.4 σ level. The seasonal modulation of the neutrino flux is also examined, but the change in flux at the SK site is predicted to be negligible, and, as expected, no evidence for a seasonal correlation is seen.

  8. Precise 238U(n,2n)237U reaction cross-section measurements using the activation facility at TUNL

    NASA Astrophysics Data System (ADS)

    Krishichayan, Fnu; Bhike, M.; Tornow, W.

    2014-09-01

    Accurate neutron-induced 238U(n,2n)237U reaction data are required for many practical applications, especially in the field of nuclear energy, including advanced heavy water reactors, where 238U is used as the breeding material to regenerate the fissile material 239Pu. Precise (n,2n) cross-section measurements of 238U are underway at TUNL with mono-energetic neutrons in the 8.0 to 14.0 MeV energy range in steps of 0.25 MeV using the activation technique. After activation of the 0.5 inch diameter and 442 mg 238U foil, the activity of the 208 keV characteristic γ-line is tracked for 6 weeks with a high efficient HPGe clover detector to determine the initial activity needed for the cross-section determination. Results of the cross-section measurements, determined relative to 27Al and 197Au neutron activation monitor foils, and the comparison with theoretical models will be presented during the meeting.

  9. Solar Energy Education. Humanities: activities and teacher's guide. Field test edition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1982-01-01

    Activities are outlined to introduce students to information on solar energy while performing ordinary classroom work. In this teaching manual solar energy is integrated with the humanities. The activities include such things as stories, newspapers, writing assignments, and art and musical presentations all filled with energy related terms. An energy glossary is provided. (BCS)

  10. Oxygen consumption rate v. rate of energy utilization of fishes: a comparison and brief history of the two measurements.

    PubMed

    Nelson, J A

    2016-01-01

    Accounting for energy use by fishes has been taking place for over 200 years. The original, and continuing gold standard for measuring energy use in terrestrial animals, is to account for the waste heat produced by all reactions of metabolism, a process referred to as direct calorimetry. Direct calorimetry is not easy or convenient in terrestrial animals and is extremely difficult in aquatic animals. Thus, the original and most subsequent measurements of metabolic activity in fishes have been measured via indirect calorimetry. Indirect calorimetry takes advantage of the fact that oxygen is consumed and carbon dioxide is produced during the catabolic conversion of foodstuffs or energy reserves to useful ATP energy. As measuring [CO2 ] in water is more challenging than measuring [O2 ], most indirect calorimetric studies on fishes have used the rate of O2 consumption. To relate measurements of O2 consumption back to actual energy usage requires knowledge of the substrate being oxidized. Many contemporary studies of O2 consumption by fishes do not attempt to relate this measurement back to actual energy usage. Thus, the rate of oxygen consumption (M˙O2 ) has become a measurement in its own right that is not necessarily synonymous with metabolic rate. Because all extant fishes are obligate aerobes (many fishes engage in substantial net anaerobiosis, but all require oxygen to complete their life cycle), this discrepancy does not appear to be of great concern to the fish biology community, and reports of fish oxygen consumption, without being related to energy, have proliferated. Unfortunately, under some circumstances, these measures can be quite different from one another. A review of the methodological history of the two measurements and a look towards the future are included. © 2016 The Fisheries Society of the British Isles.

  11. Carrier concentration dependence of donor activation energy in n-type GaN epilayers grown on Si (1 1 1) by plasma-assisted MBE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar, Mahesh; Central Research Laboratory, Bharat Electronics, Bangalore 560 013; Bhat, Thirumaleshwara N.

    Highlights: ► The n-type GaN layers were grown by plasma-assisted molecular beam epitaxy. ► The optical characteristics of a donor level in Si-doped GaN were studied. ► Activation energy of a Si-related donor was estimated from temperature dependent PL measurements. ► PL peak positions, FWHM of PL and activation energies are found to be proportional to the cube root of carrier density. ► The involvement of donor levels is supported by the temperature-dependent electron concentration measurements. -- Abstract: The n-type GaN layers were grown by plasma-assisted MBE and either intentionally doped with Si or unintentionally doped. The optical characteristics ofmore » a donor level in Si-doped, GaN were studied in terms of photoluminescence (PL) spectroscopy as a function of electron concentration. Temperature dependent PL measurements allowed us to estimate the activation energy of a Si-related donor from temperature-induced decay of PL intensity. PL peak positions, full width at half maximum of PL and activation energies are found to be proportional to the cube root of carrier density. The involvement of donor levels is supported by the temperature-dependent electron concentration measurements.« less

  12. Enzyme activation through the utilization of intrinsic dianion binding energy.

    PubMed

    Amyes, T L; Malabanan, M M; Zhai, X; Reyes, A C; Richard, J P

    2017-03-01

    We consider 'the proposition that the intrinsic binding energy that results from the noncovalent interaction of a specific substrate with the active site of the enzyme is considerably larger than is generally believed. An important part of this binding energy may be utilized to provide the driving force for catalysis, so that the observed binding energy represents only what is left over after this utilization' [Jencks,W.P. (1975) Adv. Enzymol. Relat. Areas. Mol. Biol. , , 219-410]. The large ~12 kcal/mol intrinsic substrate phosphodianion binding energy for reactions catalyzed by triosephosphate isomerase (TIM), orotidine 5'-monophosphate decarboxylase and glycerol-3-phosphate dehydrogenase is divided into 4-6 kcal/mol binding energy that is expressed on the formation of the Michaelis complex in anchoring substrates to the respective enzyme, and 6-8 kcal/mol binding energy that is specifically expressed at the transition state in activating the respective enzymes for catalysis. A structure-based mechanism is described where the dianion binding energy drives a conformational change that activates these enzymes for catalysis. Phosphite dianion plays the active role of holding TIM in a high-energy closed active form, but acts as passive spectator in showing no effect on transition-state structure. The result of studies on mutant enzymes is presented, which support the proposal that the dianion-driven enzyme conformational change plays a role in enhancing the basicity of side chain of E167, the catalytic base, by clamping the base between a pair of hydrophobic side chains. The insight these results provide into the architecture of enzyme active sites and the development of strategies for the de novo design of protein catalysts is discussed. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  13. β-particle energy-summing correction for β-delayed proton emission measurements

    DOE PAGES

    Meisel, Z.; del Santo, M.; Crawford, H. L.; ...

    2016-11-14

    One common approach to studying β-delayed proton emission is to measure the energy of the emitted proton and corresponding nuclear recoil in a double-sided silicon-strip detector (DSSD) after implanting the β-delayed proton-emitting (βp) nucleus. However, in order to extract the proton-decay energy, the measured energy must be corrected for the additional energy implanted in the DSSD by the β-particle emitted from the βp nucleus, an effect referred to here as β-summing. Here, we present an approach to determine an accurate correction for β-summing. Our method relies on the determination of the mean implantation depth of the βp nucleus within themore » DSSD by analyzing the shape of the total (proton + recoil + β) decay energy distribution shape. We validate this approach with other mean implantation depth measurement techniques that take advantage of energy deposition within DSSDs upstream and downstream of the implantation DSSD.« less

  14. The energy cost of playing active video games in children with obesity and children of a healthy weight.

    PubMed

    O'Donovan, C; Roche, E F; Hussey, J

    2014-08-01

    Increasing physical activity and reducing sedentary behaviour form a large part of the treatment of paediatric obesity. However, many children today spend prolonged periods of time playing sedentary video games. Active video games (AVGs) represent a novel and child friendly form of physical activity. To measure the energy cost of playing two AVGs in children with obesity and healthy age- and gender-matched children. The energy cost of gaming and heart rates achieved during gaming conditions were compared between groups. AVG play can result in light-to-moderate intensity physical activity (2.7-5.4 metabolic equivalents). When corrected for fat-free mass those with obesity expended significantly less energy than healthy weight peers playing Nintendo Wii Fit Free Jogging (P = 0.017). No significant difference was seen between groups in the energy cost of playing Boxing. Certain AVGs, particularly those that require lower limb movement, could be used to increase total energy expenditure, replace more sedentary activities, or achieve moderate intensity physical activity among children with obesity. There seems to be some differences in how children with obesity and children of a healthy weight play AVGs. This could result in those with obesity expending less energy than their lean peers during AVG play. © 2013 The Authors. Pediatric Obesity © 2013 International Association for the Study of Obesity.

  15. Safe Active Scanning for Energy Delivery Systems Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Helms, J.; Salazar, B.; Scheibel, P.

    The Department of Energy’s Cybersecurity for Energy Delivery Systems Program has funded Safe(r) Active Scanning for Energy Delivery Systems, led by Lawrence Livermore National Laboratory, to investigate and analyze the impacts of active scanning in the operational environment of energy delivery systems. In collaboration with Pacific Northwest National Laboratory and Idaho National Laboratory, active scans across three testbeds including 38 devices were performed. This report gives a summary of the initial literature survey performed on the SASEDS project as well as industry partner interview summaries and main findings from Phase 1 of the project. Additionally, the report goes into themore » details of scanning techniques, methodologies for testing, testbed descriptions, and scanning results, with appendices to elaborate on the specific scans that were performed. As a result of testing, a single device out of 38 exhibited problems when actively scanned, and a reboot was required to fix it. This single failure indicates that active scanning is not likely to have a detrimental effect on the safety and resilience of energy delivery systems. We provide a path forward for future research that could enable wide adoption of active scanning and lead utilities to incorporate active scanning as part of their default network security plans to discover and rectify rogue devices, adversaries, and services that may be on the network. This increased network visibility will allow operational technology cybersecurity practitioners to improve their situational awareness of networks and their vulnerabilities.« less

  16. Measuring physical activity during pregnancy.

    PubMed

    Harrison, Cheryce L; Thompson, Russell G; Teede, Helena J; Lombard, Catherine B

    2011-03-21

    Currently, little is known about physical activity patterns in pregnancy with prior estimates predominantly based on subjective assessment measures that are prone to error. Given the increasing obesity rates and the importance of physical activity in pregnancy, we evaluated the relationship and agreement between subjective and objective physical activity assessment tools to inform researchers and clinicians on optimal assessment of physical activity in pregnancy. 48 pregnant women between 26-28 weeks gestation were recruited. The Yamax pedometer and Actigraph accelerometer were worn for 5-7 days under free living conditions and thereafter the International Physical Activity Questionnaire (IPAQ) was completed. IPAQ and pedometer estimates of activity were compared to the more robust and accurate accelerometer data. Of 48 women recruited, 30 women completed the study (mean age: 33.6 ± 4.7 years; mean BMI: 31.2 ± 5.1 kg/m(2)) and 18 were excluded (failure to wear [n = 8] and incomplete data [n = 10]). The accelerometer and pedometer correlated significantly on estimation of daily steps (ρ = 0.69, p < 0.01) and had good absolute agreement with low systematic error (mean difference: 505 ± 1498 steps/day). Accelerometer and IPAQ estimates of total, light and moderate Metabolic Equivalent minutes/day (MET min(-1) day(-1)) were not significantly correlated and there was poor absolute agreement. Relative to the accelerometer, the IPAQ under predicted daily total METs (105.76 ± 259.13 min(-1) day(-1)) and light METs (255.55 ± 128.41 min(-1) day(-1)) and over predicted moderate METs (-112.25 ± 166.41 min(-1) day(-1)). Compared with the accelerometer, the pedometer appears to provide a reliable estimate of physical activity in pregnancy, whereas the subjective IPAQ measure performed less accurately in this setting. Future research measuring activity in pregnancy should optimally encompass objective measures of physical activity. Australian New Zealand Clinical Trial

  17. Measuring physical activity during pregnancy

    PubMed Central

    2011-01-01

    Background Currently, little is known about physical activity patterns in pregnancy with prior estimates predominantly based on subjective assessment measures that are prone to error. Given the increasing obesity rates and the importance of physical activity in pregnancy, we evaluated the relationship and agreement between subjective and objective physical activity assessment tools to inform researchers and clinicians on optimal assessment of physical activity in pregnancy. Methods 48 pregnant women between 26-28 weeks gestation were recruited. The Yamax pedometer and Actigraph accelerometer were worn for 5-7 days under free living conditions and thereafter the International Physical Activity Questionnaire (IPAQ) was completed. IPAQ and pedometer estimates of activity were compared to the more robust and accurate accelerometer data. Results Of 48 women recruited, 30 women completed the study (mean age: 33.6 ± 4.7 years; mean BMI: 31.2 ± 5.1 kg/m2) and 18 were excluded (failure to wear [n = 8] and incomplete data [n = 10]). The accelerometer and pedometer correlated significantly on estimation of daily steps (ρ = 0.69, p < 0.01) and had good absolute agreement with low systematic error (mean difference: 505 ± 1498 steps/day). Accelerometer and IPAQ estimates of total, light and moderate Metabolic Equivalent minutes/day (MET min-1 day-1) were not significantly correlated and there was poor absolute agreement. Relative to the accelerometer, the IPAQ under predicted daily total METs (105.76 ± 259.13 min-1 day-1) and light METs (255.55 ± 128.41 min-1 day-1) and over predicted moderate METs (-112.25 ± 166.41 min-1 day-1). Conclusion Compared with the accelerometer, the pedometer appears to provide a reliable estimate of physical activity in pregnancy, whereas the subjective IPAQ measure performed less accurately in this setting. Future research measuring activity in pregnancy should optimally encompass objective measures of physical activity. Trial Registration

  18. Fusion-neutron-yield, activation measurements at the Z accelerator: design, analysis, and sensitivity.

    PubMed

    Hahn, K D; Cooper, G W; Ruiz, C L; Fehl, D L; Chandler, G A; Knapp, P F; Leeper, R J; Nelson, A J; Smelser, R M; Torres, J A

    2014-04-01

    We present a general methodology to determine the diagnostic sensitivity that is directly applicable to neutron-activation diagnostics fielded on a wide variety of neutron-producing experiments, which include inertial-confinement fusion (ICF), dense plasma focus, and ion beam-driven concepts. This approach includes a combination of several effects: (1) non-isotropic neutron emission; (2) the 1/r(2) decrease in neutron fluence in the activation material; (3) the spatially distributed neutron scattering, attenuation, and energy losses due to the fielding environment and activation material itself; and (4) temporally varying neutron emission. As an example, we describe the copper-activation diagnostic used to measure secondary deuterium-tritium fusion-neutron yields on ICF experiments conducted on the pulsed-power Z Accelerator at Sandia National Laboratories. Using this methodology along with results from absolute calibrations and Monte Carlo simulations, we find that for the diagnostic configuration on Z, the diagnostic sensitivity is 0.037% ± 17% counts/neutron per cm(2) and is ∼ 40% less sensitive than it would be in an ideal geometry due to neutron attenuation, scattering, and energy-loss effects.

  19. Physical activity, sleep pattern and energy expenditure in double-handed offshore sailing.

    PubMed

    Galvani, C; Ardigò, L P; Alberti, M; Daniele, F; Capelli, C

    2015-12-01

    The aim of the present study was to quantify total energy expenditure, activity energy expenditure and time spent at three levels of physical activity (low, moderate, high intensity) in four two-person crews during a 500-mile double-handed sailing regatta. Physical activity intensity and energy expenditure were assessed during a 500-nautical-mile double-handed offshore competition in eight male sailors (46.3±3.4 years; 180±13 cm; 85.4±12.5 kg). During the whole regatta, they wore an activity monitor that estimated energy expenditure and minutes spent at each level of intensity (sedentary, <1.5 METs; light physical activity, 1.5-2.9 METs; moderate physical activity, 3.0-6.0 METs; vigorous physical activity, >6.0 METs). The sailors spent longer periods (P<0.0001) of time in sedentary (823±193 min/day) and light physical activities (516±177 min/day) than in moderate (95±34 min/day) or vigorous (6±4 min/day) physical activities. They slept 5 times per day (±1.4) for 36 min (±9) in each sleeping period. The total energy expenditure was 14.26±1.89 MJ/day and the activity energy expenditure was 5.06±1.42 MJ/day. Activity energy expenditure was significantly correlated with total sleep time, boat speed, and distance covered each day (P<0.05). CONCLUSION;:The high total energy expenditure was more likely a consequence of the short and rare periods of sleep during the competition rather than of the bouts of moderate and vigorous physical activities.

  20. Leptin and energy restriction induced adaptation in energy expenditure.

    PubMed

    Camps, Stefan G J A; Verhoef, Sanne P M; Westerterp, Klaas R

    2015-10-01

    Diet-induced weight loss is accompanied by adaptive thermogenesis, i.e. a disproportional reduction of resting energy expenditure (REE) a decrease in physical activity and increased movement economy. To determine if energy restriction induced adaptive thermogenesis and adaptations in physical activity are related to changes in leptin concentrations. Eighty-two healthy subjects (23 men, 59 women), mean ± SD age 41 ± 8 years and BMI 31.9 ± 3.0 kg/m(2), followed a very low energy diet for 8 weeks with measurements before and after the diet. Leptin concentrations were determined from fasting blood plasma. Body composition was assessed with a three-compartment model based on body weight, total body water (deuterium dilution) and body volume (BodPod). REE was measured (REEm) with a ventilated hood and predicted (REEp) from measured body composition. Adaptive thermogenesis was calculated as REEm/REEp. Parameters for the amount of physical activity were total energy expenditure expressed as a multiple of REEm (PAL), activity-induced energy expenditure divided by body weight (AEE/kg) and activity counts measured by a tri-axial accelerometer. Movement economy was calculated as AEE/kg (MJ/kg/d) divided by activity counts (Mcounts/d). Subjects lost on average 10.7 ± 4.1% body weight (P<0.001). Leptin decreased from 26.9 ± 14.3 before to 13.9 ± 11.3 μg/l after the diet (P<0.001). REEm/REEp after the diet (0.963 ± 0.08) was related to changes in leptin levels (R(2)=0.06; P<0.05). There was no significant correlation between changes in leptin concentrations and changes in amount of physical activity. Movement economy changed from 0.036 ± 0.011 J/kg/count to 0.028 ± 0.010 J/kg/count and was correlated to the changes in leptin concentrations (R(2)=0.07; P<0.05). During energy restriction, the decrease in leptin explains part of the variation in adaptive thermogenesis. Changes in leptin are not related to the amount of physical activity but could partly explain the

  1. Redox-active Hybrid Materials for Pseudocapacitive Energy Storage

    NASA Astrophysics Data System (ADS)

    Boota, Muhammad

    Organic-inorganic hybrid materials show a great promise for the purpose of manufacturing high performance electrode materials for electrochemical energy storage systems and beyond. Molecular level combination of two best suited components in a hybrid material leads to new or sometimes exceptional sets of physical, chemical, mechanical and electrochemical properties that makes them attractive for broad ranges of applications. Recently, there has been growing interest in producing redox-active hybrid nanomaterials for energy storage applications where generally the organic component provides high redox capacitance and the inorganic component offers high conductivity and robust support. While organic-inorganic hybrid materials offer tremendous opportunities for electrochemical energy storage applications, the task of matching the right organic material out of hundreds of natural and nearly unlimited synthetic organic molecules to appropriate nanostructured inorganic support hampers their electrochemical energy storage applications. We aim to present the recent development of redox-active hybrid materials for pseudocapacitive energy storage. We will show the impact of combination of suitable organic materials with distinct carbon nanostructures and/or highly conductive metal carbides (MXenes) on conductivity, charge storage performance, and cyclability. Combined experimental and molecular simulation results will be discussed to shed light on the interfacial organic-inorganic interactions, pseudocapacitive charge storage mechanisms, and likely orientations of organic molecules on conductive supports. Later, the concept of all-pseudocapacitive organic-inorganic asymmetric supercapacitors will be highlighted which open up new avenues for developing inexpensive, sustainable, and high energy density aqueous supercapacitors. Lastly, future challenges and opportunities to further tailor the redox-active hybrids will be highlighted.

  2. Assessment of physical activity, energy expenditure and energy intakes of young men practicing aerobic sports.

    PubMed

    Wierniuk, Alicja; Włodarek, Dariusz

    2014-01-01

    Adequate nutrition and energy intake play key rule during the training period and recovery time. The assessment of athlete's energetic needs should be calculated individually, based on personal energy expenditure and Sense Wear PRO3 Armband (SWA) mobile monitor is a useful tool to achieve this goal. However, there is still few studies conducted with use of this monitor. To assess individual energy needs of athletes by use of SWA and to determine whether their energy intake fulfils the body's energy expenditure. Subjects were 15 male students attending Military University of Technology in Warsaw, aged 19-24 years, practicing aerobic. The average body mass was 80.7 ± 7.7 kg and average height was 186.9 ± 5.2 cm, (BMI 23.09 ± 1.85 kg/m2). Assessment of physical activity and energy expenditure (TEE) was established using SWA, which was placed on the back side of dominant hand and worn continuously for 48 hours (during the training and non-training day). The presented results are the average values of these 2 days. Assessment of athletes' physical activity level was established by use of metabolic equivalent of task (MET) and number of steps (NS). Estimation of energy intake was based on three-day dietary recalls (two weekdays and one day of the weekend), evaluated using the Polish Software 'Energia' package. The average TEE of examined athletes was 3877 ± 508 kcal/day and almost half of this energy was spend on physical activity (1898 ± 634 kcal/day). The number of steps was on average 19498 ± 5407 and average MET was 2.05 ± 2.09. The average daily energy intake was 2727 ± 576 kcal. Athletes consumed inadequate amount of energy in comparison to their energy expenditure. Examined group did not have an adequate knowledge about their energy requirement, which shows the need of nutritional consulting and education among these athletes. athletes, aerobic sports, energy expenditure, energy intake.

  3. Active-Interrogation Measurements of Induced-Fission Neutrons from Low-Enriched Uranium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. L. Dolan; M. J. Marcath; M. Flaska

    2012-07-01

    Protection and control of nuclear fuels is paramount for nuclear security and safeguards; therefore, it is important to develop fast and robust controlling mechanisms to ensure the safety of nuclear fuels. Through both passive- and active-interrogation methods we can use fast-neutron detection to perform real-time measurements of fission neutrons for process monitoring. Active interrogation allows us to use different ranges of incident neutron energy to probe for different isotopes of uranium. With fast-neutron detectors, such as organic liquid scintillation detectors, we can detect the induced-fission neutrons and photons and work towards quantifying a sample’s mass and enrichment. Using MCNPX-PoliMi, amore » system was designed to measure induced-fission neutrons from U-235 and U-238. Measurements were then performed in the summer of 2010 at the Joint Research Centre in Ispra, Italy. Fissions were induced with an associated particle D-T generator and an isotopic Am-Li source. The fission neutrons, as well as neutrons from (n, 2n) and (n, 3n) reactions, were measured with five 5” by 5” EJ-309 organic liquid scintillators. The D-T neutron generator was available as part of a measurement campaign in place by Padova University. The measurement and data-acquisition systems were developed at the University of Michigan utilizing a CAEN V1720 digitizer and pulse-shape discrimination algorithms to differentiate neutron and photon detections. Low-enriched uranium samples of varying mass and enrichment were interrogated. Acquired time-of-flight curves and cross-correlation curves are currently analyzed to draw relationships between detected neutrons and sample mass and enrichment. In the full paper, the promise of active-interrogation measurements and fast-neutron detection will be assessed through the example of this proof-of-concept measurement campaign. Additionally, MCNPX-PoliMi simulation results will be compared to the measured data to validate the MCNPX

  4. AXAF VETA-I mirror encircled energy measurements and data reduction

    NASA Technical Reports Server (NTRS)

    Zhao, Ping; Freeman, Mark D.; Hughes, John P.; Kellogg, Edwin M.; Nguyen, Dan T.; Joy, Marshall; Kolodziejczak, Jeffery J.

    1992-01-01

    The AXAF VETA-I mirror encircled energy was measured with a series of apertures and two flow gas proportional counters at five X-ray energies ranging from 0.28 to 2.3 keV. The proportional counter has a thin plastic window with an opaque wire mesh supporting grid. Depending on the counter position, this mesh can cause the X-ray transmission to vary as much as +/-9 percent, which directly translates into an error in the encircled energy. In order to correct this wire mesh effect, window scan measurements were made, in which the counter was scanned in both horizontal (Y) and vertical (Z) directions with the aperture fixed. Post VETA measurement of the VXDS setup were made to determine the exact geometry and position of the mesh grid. Computer models of the window mesh were developed to simulate the X-ray transmission based on this measurement. The window scan data were fitted to such mesh models and corrections were made. After this study, the mesh effect was well understood and the final results of the encircled energy were obtained with an uncertainty of less than 0.8 percent.

  5. Assessment of Uncertainty in the Determination of Activation Energy for Polymeric Materials

    NASA Technical Reports Server (NTRS)

    Darby, Stephania P.; Landrum, D. Brian; Coleman, Hugh W.

    1998-01-01

    An assessment of the experimental uncertainty in obtaining the kinetic activation energy from thermogravimetric analysis (TGA) data is presented. A neat phenolic resin, Borden SC1O08, was heated at three heating rates to obtain weight loss vs temperature data. Activation energy was calculated by two methods: the traditional Flynn and Wall method based on the slope of log(q) versus 1/T, and a modification of this method where the ordinate and abscissa are reversed in the linear regression. The modified method produced a more accurate curve fit of the data, was more sensitive to data nonlinearity, and gave a value of activation energy 75 percent greater than the original method. An uncertainty analysis using the modified method yielded a 60 percent uncertainty in the average activation energy. Based on this result, the activation energy for a carbon-phenolic material was doubled and used to calculate the ablation rate In a typical solid rocket environment. Doubling the activation energy increased surface recession by 3 percent. Current TGA data reduction techniques that use the traditional Flynn and Wall approach to calculate activation energy should be changed to the modified method.

  6. Energy requirements of lactating women derived from doubly labeled water and milk energy output.

    PubMed

    Butte, N F; Wong, W W; Hopkinson, J M

    2001-01-01

    Instead of using an incremental approach to assess the energy requirements of lactation, a more comprehensive approach may be taken by measuring total energy expenditure (TEE), milk energy output and energy mobilization from tissue stores. The latter approach avoids assumptions regarding energetic efficiency and changes in physical activity and adiposity. The purpose of this study was threefold: to assess the energy requirements of lactation; to compare these estimates with energy requirements in the nonpregnant, nonlactating state and to test for energetic adaptations in basal metabolic rate (BMR) and physical activity during the energy-demanding process of lactation. Milk production and composition, body weight and composition, TEE, BMR and physical activity levels were measured in 24 well-nourished women during exclusive breastfeeding at 3 mo postpartum and after the cessation of breastfeeding at 18 or 24 mo postpartum. TEE was measured by the doubly labeled water method, milk production by 3-d test-weighing, milk energy by bomb calorimetry on a 24-h milk sample, body composition by dual-energy x-ray absorptiometry and BMR by room respiration calorimetry. TEE, BMR and physical activity level (physical activity level = TEE/BMR) did not differ between the lactating and nonlactating state (TEE 10.0 +/- 1.5 versus 10.6 +/- 2.1 MJ/d). Mean milk energy output was equivalent to 2.02 +/- 0.33 MJ/d. Total energy requirements were greater during lactation than afterward (12.0 +/- 1.4 versus 10.6 +/- 2.1 MJ/d, P: = 0.002). Energy mobilization from tissue stores (-0.65 +/- 0.97 MJ/d) resulted in net energy requirements during lactation of 11.4 +/- 1.8 MJ/d. Because adaptations in basal metabolism and physical activity were not evident in these well-nourished women, energy requirements during lactation were met primarily from the diet and only partially by mobilization of tissue stores.

  7. Impact of Personalised Feedback about Physical Activity on Change in Objectively Measured Physical Activity (the FAB Study): A Randomised Controlled Trial

    PubMed Central

    Godino, Job G.; Watkinson, Clare; Corder, Kirsten; Marteau, Theresa M.; Sutton, Stephen; Sharp, Stephen J.; Griffin, Simon J.; van Sluijs, Esther M. F.

    2013-01-01

    Background Low levels of physical activity are a major public health concern, and interventions to promote physical activity have had limited success. Whether or not personalised feedback about physical activity following objective measurement motivates behaviour change has yet to be rigorously examined. Methods And Findings: In a parallel group, open randomised controlled trial, 466 healthy adults aged 32 to 54 years were recruited from the ongoing population-based Fenland Study (Cambridgeshire, UK). Participants were randomised to receive either no feedback until the end of the trial (control group, n=120) or one of three different types of feedback: simple, visual, or contextualised (intervention groups, n=346). The primary outcome was physical activity (physical activity energy expenditure (PAEE) in kJ/kg/day and average body acceleration (ACC) in m/s2) measured objectively using a combined heart rate monitor and accelerometer (Actiheart®). The main secondary outcomes included self-reported physical activity, intention to increase physical activity, and awareness of physical activity (the agreement between self-rated and objectively measured physical activity). At 8 weeks, 391 (83.9%) participants had complete physical activity data. The intervention had no effect on objectively measured physical activity (PAEE: β=-0.92, 95% CI=-3.50 to 1.66, p=0.48 and ACC: β=0.01, 95% CI=-0.00 to 0.02, p=0.21), self-reported physical activity (β=-0.39, 95% CI=-1.59 to 0.81), or intention to increase physical activity (β=-0.05, 95% CI=-0.22 to 0.11). However, it was associated with an increase in awareness of physical activity (OR=1.74, 95% CI=1.05 to 2.89). Results did not differ according to the type of feedback. Conclusions Personalised feedback about physical activity following objective measurement increased awareness but did not result in changes in physical activity in the short term. Measurement and feedback may have a role in promoting behaviour change but are

  8. Impact of personalised feedback about physical activity on change in objectively measured physical activity (the FAB study): a randomised controlled trial.

    PubMed

    Godino, Job G; Watkinson, Clare; Corder, Kirsten; Marteau, Theresa M; Sutton, Stephen; Sharp, Stephen J; Griffin, Simon J; van Sluijs, Esther M F

    2013-01-01

    Low levels of physical activity are a major public health concern, and interventions to promote physical activity have had limited success. Whether or not personalised feedback about physical activity following objective measurement motivates behaviour change has yet to be rigorously examined. And Findings: In a parallel group, open randomised controlled trial, 466 healthy adults aged 32 to 54 years were recruited from the ongoing population-based Fenland Study (Cambridgeshire, UK). Participants were randomised to receive either no feedback until the end of the trial (control group, n=120) or one of three different types of feedback: simple, visual, or contextualised (intervention groups, n=346). The primary outcome was physical activity (physical activity energy expenditure (PAEE) in kJ/kg/day and average body acceleration (ACC) in m/s(2)) measured objectively using a combined heart rate monitor and accelerometer (Actiheart(®)). The main secondary outcomes included self-reported physical activity, intention to increase physical activity, and awareness of physical activity (the agreement between self-rated and objectively measured physical activity). At 8 weeks, 391 (83.9%) participants had complete physical activity data. The intervention had no effect on objectively measured physical activity (PAEE: β=-0.92, 95% CI=-3.50 to 1.66, p=0.48 and ACC: β=0.01, 95% CI=-0.00 to 0.02, p=0.21), self-reported physical activity (β=-0.39, 95% CI=-1.59 to 0.81), or intention to increase physical activity (β=-0.05, 95% CI=-0.22 to 0.11). However, it was associated with an increase in awareness of physical activity (OR=1.74, 95% CI=1.05 to 2.89). Results did not differ according to the type of feedback. Personalised feedback about physical activity following objective measurement increased awareness but did not result in changes in physical activity in the short term. Measurement and feedback may have a role in promoting behaviour change but are ineffective on their own

  9. Particle and Photon Detection: Counting and Energy Measurement

    PubMed Central

    Janesick, James; Tower, John

    2016-01-01

    Fundamental limits for photon counting and photon energy measurement are reviewed for CCD and CMOS imagers. The challenges to extend photon counting into the visible/nIR wavelengths and achieve energy measurement in the UV with specific read noise requirements are discussed. Pixel flicker and random telegraph noise sources are highlighted along with various methods used in reducing their contribution on the sensor’s read noise floor. Practical requirements for quantum efficiency, charge collection efficiency, and charge transfer efficiency that interfere with photon counting performance are discussed. Lastly we will review current efforts in reducing flicker noise head-on, in hopes to drive read noise substantially below 1 carrier rms. PMID:27187398

  10. Emittance measurements in low energy ion storage rings

    NASA Astrophysics Data System (ADS)

    Hunt, J. R.; Carli, C.; Resta-López, J.; Welsch, C. P.

    2018-07-01

    The development of the next generation of ultra-low energy antiproton and ion facilities requires precise information about the beam emittance to guarantee optimum performance. In the Extra-Low ENergy Antiproton storage ring (ELENA) the transverse emittances will be measured by scraping. However, this diagnostic measurement faces several challenges: non-zero dispersion, non-Gaussian beam distributions due to effects of the electron cooler and various systematic errors such as closed orbit offsets and inaccurate rms momentum spread estimation. In addition, diffusion processes, such as intra-beam scattering might lead to emittance overestimates. Here, we present algorithms to efficiently address the emittance reconstruction in presence of the above effects, and present simulation results for the case of ELENA.

  11. Measurement of high-energy neutron flux above ground utilizing a spallation based multiplicity technique

    DOE PAGES

    Roecker, Caleb; Bernstein, Adam; Marleau, Peter; ...

    2016-11-14

    Cosmogenic high-energy neutrons are a ubiquitous, difficult to shield, poorly measured background. Above ground the high-energy neutron energy-dependent flux has been measured, with significantly varying results. Below ground, high-energy neutron fluxes are largely unmeasured. Here we present a reconstruction algorithm to unfold the incident neutron energy-dependent flux measured using the Multiplicity and Recoil Spectrometer (MARS), simulated test cases to verify the algorithm, and provide a new measurement of the above ground high-energy neutron energy-dependent flux with a detailed systematic uncertainty analysis. Uncertainty estimates are provided based upon the measurement statistics, the incident angular distribution, the surrounding environment of the Montemore » Carlo model, and the MARS triggering efficiency. Quantified systematic uncertainty is dominated by the assumed incident neutron angular distribution and surrounding environment of the Monte Carlo model. The energy-dependent neutron flux between 90 MeV and 400 MeV is reported. Between 90 MeV and 250 MeV the MARS results are comparable to previous Bonner sphere measurements. Over the total energy regime measured, the MARS result are located within the span of previous measurements. Lastly, these results demonstrate the feasibility of future below ground measurements with MARS.« less

  12. Measurement of high-energy neutron flux above ground utilizing a spallation based multiplicity technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roecker, Caleb; Bernstein, Adam; Marleau, Peter

    Cosmogenic high-energy neutrons are a ubiquitous, difficult to shield, poorly measured background. Above ground the high-energy neutron energy-dependent flux has been measured, with significantly varying results. Below ground, high-energy neutron fluxes are largely unmeasured. Here we present a reconstruction algorithm to unfold the incident neutron energy-dependent flux measured using the Multiplicity and Recoil Spectrometer (MARS), simulated test cases to verify the algorithm, and provide a new measurement of the above ground high-energy neutron energy-dependent flux with a detailed systematic uncertainty analysis. Uncertainty estimates are provided based upon the measurement statistics, the incident angular distribution, the surrounding environment of the Montemore » Carlo model, and the MARS triggering efficiency. Quantified systematic uncertainty is dominated by the assumed incident neutron angular distribution and surrounding environment of the Monte Carlo model. The energy-dependent neutron flux between 90 MeV and 400 MeV is reported. Between 90 MeV and 250 MeV the MARS results are comparable to previous Bonner sphere measurements. Over the total energy regime measured, the MARS result are located within the span of previous measurements. Lastly, these results demonstrate the feasibility of future below ground measurements with MARS.« less

  13. Direct measurement of free-energy barrier to nucleation of crystallites in amorphous silicon thin films

    NASA Technical Reports Server (NTRS)

    Shi, Frank G.

    1994-01-01

    A method is introduced to measure the free-energy barrier W(sup *), the activation energy, and activation entropy to nucleation of crystallites in amorphous solids, independent of the energy barrier to growth. The method allows one to determine the temperature dependence of W(sup *), and the effect of the preparation conditions of the initial amorphous phase, the dopants, and the crystallization methds on W(sup *). The method is applied to determine the free-energy barrier to nucleation of crystallites in amorphous silicon (a-Si) thin films. For thermally induced nucleation in a-Si thin films with annealing temperatures in the range of from 824 to 983 K, the free-energy barrier W(sup *) to nucleation of silicon crystals is about 2.0 - 2.1 eV regardless of the preparation conditions of the films. The observation supports the idea that a-Si transforms into an intermediate amorphous state through the structural relaxation prior to the onset of nucleation of crystallites in a-Si. The observation also indicates that the activation entropy may be an insignificant part of the free-energy barrier for the nucleation of crystallites in a-Si. Compared with the free-energy barrier to nucleation of crystallites in undoped a-Si films, a significant reduction is observed in the free-energy barrier to nucleation in Cu-doped a-Si films. For a-Si under irradiation of Xe(2+) at 10(exp 5) eV, the free-energy barrier to ion-induced nucleation of crystallites is shown to be about half of the value associated with thermal-induced nucleation of crystallites in a-Si under the otherwise same conditions, which is much more significant than previously expected. The present method has a general kinetic basis; it thus should be equally applicable to nucleation of crystallites in any amorphous elemental semiconductors and semiconductor alloys, metallic and polymeric glasses, and to nucleation of crystallites in melts and solutions.

  14. Abnormal high-energy phosphate molecule metabolism during regional brain activation in patients with bipolar disorder.

    PubMed

    Yuksel, C; Du, F; Ravichandran, C; Goldbach, J R; Thida, T; Lin, P; Dora, B; Gelda, J; O'Connor, L; Sehovic, S; Gruber, S; Ongur, D; Cohen, B M

    2015-09-01

    Converging evidence suggests bioenergetic abnormalities in bipolar disorder (BD). In the brain, phosphocreatine (PCr) acts a reservoir of high-energy phosphate (HEP) bonds, and creatine kinases (CK) catalyze the transfer of HEP from adenosine triphosphate (ATP) to PCr and from PCr back to ATP, at times of increased need. This study examined the activity of this mechanism in BD by measuring the levels of HEP molecules during a stimulus paradigm that increased local energy demand. Twenty-three patients diagnosed with BD-I and 22 healthy controls (HC) were included. Levels of phosphorus metabolites were measured at baseline and during visual stimulation in the occipital lobe using (31)P magnetic resonance spectroscopy at 4T. Changes in metabolite levels showed different patterns between the groups. During stimulation, HC had significant reductions in PCr but not in ATP, as expected. In contrast, BD patients had significant reductions in ATP but not in PCr. In addition, PCr/ATP ratio was lower at baseline in patients, and there was a higher change in this measure during stimulation. This pattern suggests a disease-related failure to replenish ATP from PCr through CK enzyme catalysis during tissue activation. Further studies measuring the CK flux in BD are required to confirm and extend this finding.

  15. Solvent dependence of the activation energy of attachment determined by single molecule observations of surfactant adsorption.

    PubMed

    Honciuc, Andrei; Baptiste, Denver Jn; Campbell, Ian P; Schwartz, Daniel K

    2009-07-07

    Single-molecule total internal reflection fluorescence microscopy was used to obtain real-time images of fluorescently labeled hexadecanoic (palmitic) acid molecules as they adsorbed at the interface between fused silica and three different solvents: hexadecane (HD), tetrahydrofuran (THF), and water. These solvents were chosen to explore the effect of solvent polarity on the activation energy associated with the attachment rate, i.e., the rate at which molecules were transferred to the surface from the near-surface layer. Direct counting of single-molecule events, made under steady-state conditions at extremely low coverage, provided direct, model-independent measurements of this attachment rate, in contrast with conventional ensemble-averaged methods, which are influenced by bulk transport and competing detachment processes. We found that the attachment rate increased with increasing temperature for all solvents. Arrhenius analyses gave activation energies of 5+/-2 kJ/mol for adsorption from HD, 10+/-2 kJ/mol for adsorption from THF, and 19+/-2 kJ/mol for adsorption from water. These energies increased systematically with the solvent polarity and, therefore, with the expected strength of the solvent-substrate interaction. We hypothesize that the adsorption of amphiphilic solute molecules from solution can be regarded as a competitive exchange between solute molecules and surface-bound solvent. In this scenario, adsorption is an activated process, and the activation energy for attachment is associated with the solvent-substrate interaction energy.

  16. Surveying predictors of late-life longitudinal change in daily activity energy expenditure.

    PubMed

    Valiani, Vincenzo; Sourdet, Sandrine; Schoeller, Dale A; Mackey, Dawn C; Bauer, Douglas C; Glynn, Nancy W; Yamada, Yosuke; Harris, Tamara B; Manini, Todd M

    2017-01-01

    Total daily energy expenditure (TEE) is composed of resting metabolic rate (RMR), post-prandial thermogenesis and activity energy expenditure (AEE). Higher AEE is strongly associated with lower mortality and physical limitations among older adults, but factors that predict changes in AEE in septu and octogenarians are not clearly understood. To identify factors associated with late-life longitudinal change in AEE. Energy expenditure was re-assessed in 83 participants (average age at baseline, 74.4±3.2 years)-an average of 7.5±0.54 years since the baseline measure. RMR was measured using indirect calorimetry and the thermic effect of meals was estimated at 10% of TEE. AEE was calculated as: TEE(0.9)-RMR. Participants were categorized into two groups according to the estimated day-to-day precision of the doubly-labeled water technique. Those who were within 10% or increased relative to their initial AEE measurement were categorized as having preserved AEE. Participants who declined greater than 10% of their initial measurement were categorized as having reduced AEE. A variety of socio-demographic, functional and mental factors, body composition, community and personal behaviors, blood measurements and health conditions were evaluated between groups at baseline and changes during follow-up. Daily AEE declined 106.61±293.25 kcal, which equated to a 14.63±40.57 kcal/d decrease per year. Fifty-nine percent (n = 49) preserved their AEE and 41% (n = 34) declined. Those who demonstrated a decline in AEE were older, had lower walking speed at baseline and showed a higher lean mass loss during follow up. Otherwise, groups were similar for socio-demographic characteristics, body composition, mental and physical function, health conditions and community and personal behaviors at baseline and change in these factors during follow-up. This study demonstrates that AEE declines through the 8th decade of life and is associated with age, lower walking speed at baseline and lean

  17. Removing the barrier to the calculation of activation energies

    DOE PAGES

    Mesele, Oluwaseun O.; Thompson, Ward H.

    2016-10-06

    Approaches for directly calculating the activation energy for a chemical reaction from a simulation at a single temperature are explored with applications to both classical and quantum systems. The activation energy is obtained from a time correlation function that can be evaluated from the same molecular dynamics trajectories or quantum dynamics used to evaluate the rate constant itself and thus requires essentially no extra computational work.

  18. Self-Reported Physical Activity is Not a Valid Method for Measuring Physical Activity in 15-Year-Old South African Boys and Girls.

    PubMed

    Monyeki, Makama Andries; Moss, Sarah J; Kemper, Han C G; Twisk, Jos W R

    2018-06-06

    Physical activity plays an important role in the prevention of chronic lifestyle-related diseases. The development of valid instruments for the assessment of physical activity remains a challenge in field studies. The purpose of the present study was therefore to determine the level of agreement between physical activity objectively measured by the ActiHeart ® (Cambridge Neurotechnology Ltd, Cambridge, UK) device and subjectively reported physical activity by means of the International Physical Activity Questionnaire Short Form (IPAQ-SF) among adolescents attending schools in the Tlokwe Local Municipality, South Africa. A cross-sectional study design was used with a total of 63 boys and 45 girls aged 15 years who took part in the Physical Activity and Health Longitudinal Study (PHALS). Stature and weight were measured according to standard International Society for the Advancement of Kinanthropometry (ISAK) protocols. Objective physical activity (PA) was measured by a combined heart rate and accelerometer device (ActiHeart ® ) for seven consecutive days. Time spent in moderate-to-vigorous intensity physical activity (MVPA) was assessed. Subjective physical activity was assessed with the self-reported IPAQ-SF. Objective PA indicated that 93% of the participants were inactive and only 6% were highly active. The IPAQ-SF showed that 24% were inactive, with 57% active. A non-significant correlation ( r = 0.11; p = 0.29) between the ActiHeart ® measure of activity energy expenditure (AEE) and total physical activity (IPAQ-SF) was observed. The Bland⁻Altman plot showed no agreement between the two measurement instruments and also a variation in the level of equivalence. When Cohen’s kappa ( κ ) was run to determine the agreement between the two measurement instruments for estimated physical activity, a poor agreement (κ = 0.011, p < 0.005) between the two was found. The poor level of agreement between the objective measure of physical

  19. Energy cost of activities in preschool-aged children

    USDA-ARS?s Scientific Manuscript database

    The absolute energy cost of activities in children increase with age due to greater muscle mass and physical capability associated with growth and developmental maturation; however, there is a paucity of data in preschool-aged children. Study aims were 1) to describe absolute and relative energy cos...

  20. Energy deposition measurements of single 1H, 4He and 12C ions of therapeutic energies in a silicon pixel detector

    NASA Astrophysics Data System (ADS)

    Gehrke, T.; Burigo, L.; Arico, G.; Berke, S.; Jakubek, J.; Turecek, D.; Tessonnier, T.; Mairani, A.; Martišíková, M.

    2017-04-01

    In the field of ion-beam radiotherapy and space applications, measurements of the energy deposition of single ions in thin layers are of interest for dosimetry and imaging. The present work investigates the capability of a pixelated detector Timepix to measure the energy deposition of single ions in therapeutic proton, helium- and carbon-ion beams in a 300 μm-thick sensitive silicon layer. For twelve different incident beams, the measured energy deposition distributions of single ions are compared to the expected energy deposition spectra, which were predicted by detailed Monte Carlo simulations using the FLUKA code. A methodology for the analysis of the measured data is introduced in order to identify and reject signals that are either degraded or caused by multiple overlapping ions. Applying a newly proposed linear recalibration, the energy deposition measurements are in good agreement with the simulations. The twelve measured mean energy depositions between 0.72 MeV/mm and 56.63 MeV/mm in a partially depleted silicon sensor do not deviate more than 7% from the corresponding simulated values. Measurements of energy depositions above 10 MeV/mm with a fully depleted sensor are found to suffer from saturation effects due to the too high per-pixel signal. The utilization of thinner sensors, in which a lower signal is induced, could further improve the performance of the Timepix detector for energy deposition measurements.

  1. The AMP-activated protein kinase AAK-2 links energy levels and insulin-like signals to lifespan in C. elegans

    PubMed Central

    Apfeld, Javier; O'Connor, Greg; McDonagh, Tom; DiStefano, Peter S.; Curtis, Rory

    2004-01-01

    Although limiting energy availability extends lifespan in many organisms, it is not understood how lifespan is coupled to energy levels. We find that the AMP:ATP ratio, a measure of energy levels, increases with age in Caenorhabditis elegans and can be used to predict life expectancy. The C. elegans AMP-activated protein kinase α subunit AAK-2 is activated by AMP and functions to extend lifespan. In addition, either an environmental stressor that increases the AMP:ATP ratio or mutations that lower insulin-like signaling extend lifespan in an aak-2-dependent manner. Thus, AAK-2 is a sensor that couples lifespan to information about energy levels and insulin-like signals. PMID:15574588

  2. Low levels of physical activity are associated with dysregulation of energy intake and fat mass gain over 1 year12

    PubMed Central

    Shook, Robin P; Hand, Gregory A; Drenowatz, Clemens; Hebert, James R; Paluch, Amanda E; Blundell, John E; Hill, James O; Katzmarzyk, Peter T; Church, Timothy S; Blair, Steven N

    2015-01-01

    Background: Previous studies suggest that appetite may be dysregulated at low levels of activity, creating an energy imbalance that results in weight gain. Objective: The aim was to examine the relation between energy intake, physical activity, appetite, and weight gain during a 1-y follow-up period in a large sample of adults. Design: Participants included 421 individuals (mean ± SD age: 27.6 ± 3.8 y). Measurements included the following: energy intake with the use of interviewer-administered dietary recalls and calculated by using changes in body composition and energy expenditure, moderate-to-vigorous physical activity (MVPA) with the use of an arm-based monitor, body composition with the use of dual-energy X-ray absorptiometry, and questionnaire-derived perceptions of dietary restraint, disinhibition, hunger, and control of eating. Participants were grouped at baseline into quintiles of MVPA (min/d) by sex. Measurements were repeated every 3 mo for 1 y. Results: At baseline, an inverse relation existed between body weight and activity groups, with the least-active group (15.7 ± 9.9 min MVPA/d, 6062 ± 1778 steps/d) having the highest body weight (86.3 ± 13.2 kg) and the most-active group (174.5 ± 60.5 min MVPA/d, 10260 ± 3087 steps/d) having the lowest body weight (67.5 ± 11.0 kg). A positive relation was observed between calculated energy intake and activity group, except in the lowest quintile of activity. The lowest physical activity group reported higher levels of disinhibition (P = 0.07) and cravings for savory foods (P = 0.03) compared with the group with the highest level of physical activity. Over 1 y of follow-up, the lowest activity group gained the largest amount of fat mass (1.7 ± 0.3 kg) after adjustment for change in MVPA and baseline fat mass. The odds of gaining >3% of fat mass were between 1.8 and 3.8 times as high for individuals in the least-active group as for those in the middle activity group. Conclusions: These results suggest

  3. Activity Profile and Energy Expenditure Among Active Older Adults, British Columbia, 2011–2012

    PubMed Central

    Ashe, Maureen C.; Chase, Jocelyn M.

    2015-01-01

    Introduction Time spent by young adults in moderate to vigorous activity predicts daily caloric expenditure. In contrast, caloric expenditure among older adults is best predicted by time spent in light activity. We examined highly active older adults to examine the biggest contributors to energy expenditure in this population. Methods Fifty-four community-dwelling men and women aged 65 years or older (mean, 71.4 y) were enrolled in this cross-sectional observational study. All were members of the Whistler Senior Ski Team, and all met current American guidelines for physical activity. Activity levels (sedentary, light, and moderate to vigorous) were recorded by accelerometers worn continuously for 7 days. Caloric expenditure was measured using accelerometry, galvanic skin response, skin temperature, and heat flux. Significant variables were entered into a stepwise multivariate linear model consisting of activity level, age, and sex. Results The average (standard deviation [SD]) daily nonlying sedentary time was 564 (92) minutes (9.4 [1.5] h) per day. The main predictors of higher caloric expenditure were time spent in moderate to vigorous activity (standardized β = 0.42 [SE, 0.08]; P < .001) and male sex (standardized β = 1.34 [SE, 0.16]; P < .001). A model consisting of only moderate to vigorous physical activity and sex explained 68% of the variation in caloric expenditure. An increase in moderate to vigorous physical activity by 1 minute per day was associated with an additional 16 kcal expended in physical activity. Conclusion The relationship between activity intensity and caloric expenditure in athletic seniors is similar to that observed in young adults. Active older adults still spend a substantial proportion of the day engaged in sedentary behaviors. PMID:26182147

  4. Measurement of Continuous-Energy Neutron-Incident Neutron-Production Cross Section

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shigyo, Nobuhiro; Kunieda, Satoshi; Watanabe, Takehito

    Continuous energy neutron-incident neutron-production double differential cross sections were measured at the Weapons Neutron Research (WNR) facility of the Los Alamos Neutron Science Center. The energy of emitted neutrons was derived from the energy deposition in a detector. The incident-neutron energy was obtained by the time-of-flight method between the spallation target of WNR and the emitted neutron detector. Two types of detectors were adopted to measure the wide energy range of neutrons. The liquid organic scintillators covered up to 100 MeV. The recoil proton detectors that constitute the recoil proton radiator and phoswich type NaI (Tl) scintillators were used formore » neutrons above several tens of MeV. Iron and lead were used as sample materials. The experimental data were compared with the evaluated nuclear data, the results of GNASH, JQMD, and PHITS codes.« less

  5. FTO variant, energy intake, physical activity and basal metabolic rate in Caucasians. The HAPIEE study.

    PubMed

    Hubáček, J A; Pikhart, H; Peasey, A; Kubínová, R; Bobák, M

    2011-01-01

    The FTO gene variants are the most important genetic determinants of body weight and obesity known so far, but the mechanism of their effect remains unclear. We have analyzed FTO rs17817449 variant (G>T in first intron) in 6024 adults aged 45-69 years to assess the potential mediating role of diet and physical activity. Diet was assessed by a 140-item food frequency questionnaire. Physical activity was measured by hours spent during a typical week by sport, walking and other activities outside of work requiring heavy and medium physical activity. Basal metabolic rate was calculated according Schofield formula. The FTO variant was significantly associated with body mass index (means in GG, GT and TT carriers were 28.7, 28.2 and 27.8 kg/m(2), p<0.001) and basal metabolic rate (BMR) (means in GG, GT and TT were 1603, 1588 and 1576 kcal per day, respectively, p<0.008) but it was not associated with physical activity, total energy intake or with energy intakes from fat, carbohydrates, proteins or alcohol. Results were essentially similar in men and women and the adjustment for physical activity or dietary energy intake did not reduce the effect of the FTO polymorphism. Means of BMR per kg of body weight was lowest in GG carriers (20.09, 20.21 for GT and 20.30 for TT, p<0.006) and this effect was more pronounced in females. These results suggest that the effect of the FTO rs17817449 variant on BMI in Caucasian adults is not mediated by energy intake or physical activity, but some effect on BMR per kg of body weight is possible.

  6. Direct observation of a photochemical activation energy: a case study of acetone photodissociation

    NASA Astrophysics Data System (ADS)

    Koch, Markus; Heim, Pascal; Thaler, Bernhard; Kitzler, Markus; Ernst, Wolfgang E.

    2017-06-01

    The ability to observe and quantify the conversion of electronic potential energy to vibrational kinetic energy in a molecule after photoexcitation is essential to understand and control the outcome of photoinduced molecular fragmentation. We exploit the high selectivity of photoelectron-photoion coincidence detection to distinguish different relaxation channels and observe the fragmentation behavior of each channel. We demonstrate the concept by investigating the fragmentation of gas-phase acetone molecules initiated by three-photon excitation to high lying Rydberg states between 9.0 and 9.5 eV above the ground state. By applying variations of the photon energy, pulse duration (100-200 fs) and pulse energy, we are able to fully characterize the fragmentation process. Rydberg states between 5s and 8s are populated, which undergo ultrafast internal conversion to lower states. The corresponding non-adiabatic dynamics in the neutral molecule cause the conversion of electronic to vibrational energy, leading to fragmentation. Our scheme allows us to directly measure the activation energy for fragmentation of acetone to an acetyl ion and a methyl radical, which we determine to be (0.79 ± 0.04) eV. Longer laser pulses result in an increased fragment-to-parent ratio, representing a higher probability for relaxation because the relaxation time constants are comparable to the pulse duration. Upon excitation to Rydberg states at 9.5 eV we surprisingly observe reduced fragmentation, although ˜2 eV are coupled into vibrational energy, indicating that different relaxation pathways become active, which results in a change of the redistribution of vibrational energy within the molecule. Fragmentation due to subsequent excitation of the cation is found to play a minor role.

  7. Selected Energy Education Activities for Pennsylvania Middle School Grades. Draft.

    ERIC Educational Resources Information Center

    Hack, Nancy; And Others

    These activities are intended to help increase awareness and understanding of the energy situation and to encourage students to become energy conservationists. The document is divided into sections according to discipline area. A final section is devoted to interdisciplinary activities involving several discipline areas integrated with the energy…

  8. Retarding field energy analyzer for high energy pulsed electron beam measurements.

    PubMed

    Hu, Jing; Rovey, Joshua L; Zhao, Wansheng

    2017-01-01

    A retarding field energy analyzer (RFEA) designed specifically for high energy pulsed electron beam measurements is described in this work. By proper design of the entrance grid, attenuation grid, and beam collector, this RFEA is capable of determining the time-resolved energy distribution of high energy pulsed electron beams normally generated under "soft vacuum" environment. The performance of the RFEA is validated by multiple tests of the leakage current, attenuation coefficient, and response time. The test results show that the retarding potential in the RFEA can go up to the same voltage as the electron beam source, which is 20 kV for the maximum in this work. Additionally, an attenuation coefficient of 4.2 is obtained in the RFEA while the percent difference of the rise time of the electron beam pulse before and after attenuation is lower than 10%. When compared with a reference source, the percent difference of the RFEA response time is less than 10% for fall times greater than 35 ns. Finally, the test results of the 10 kV pseudospark-based pulsed electron beam currents collected under varying retarding potentials are presented in this paper.

  9. Fabric-based integrated energy devices for wearable activity monitors.

    PubMed

    Jung, Sungmook; Lee, Jongsu; Hyeon, Taeghwan; Lee, Minbaek; Kim, Dae-Hyeong

    2014-09-01

    A wearable fabric-based integrated power-supply system that generates energy triboelectrically using human activity and stores the generated energy in an integrated supercapacitor is developed. This system can be utilized as either a self-powered activity monitor or as a power supply for external wearable sensors. These demonstrations give new insights for the research of wearable electronics. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. High energy expenditure masks low physical activity in obesity.

    PubMed

    DeLany, J P; Kelley, D E; Hames, K C; Jakicic, J M; Goodpaster, B H

    2013-07-01

    To investigate energy expenditure in lean and obese individuals, focusing particularly on physical activity and severely obese individuals. Total daily energy expenditure (TDEE) was assessed using doubly labeled water, resting metabolic rate (RMR) by indirect calorimetry, activity energy expenditure (AEE) by difference and time spent in physical activity by multisensor activity monitors. In all, 177 lean, Class I and severely obese individuals (age 31-56 years, body mass index 20-64 kg m(-2)) were analyzed. All components of energy expenditure were elevated in obese individuals. For example, TDEE was 2404±95 kcal per day in lean and 3244±48 kcal per day in Class III obese individuals. After appropriate adjustment, RMR was similar in all groups. Analysis of AEE by body weight and obesity class indicated a lower AEE in obese individuals. Confirming lower physical activity, obese individuals spent less time engaged in moderate-to-vigorous physical activity (2.7±1.3, 1.8±0.6, 2.0±1.4 and 1.2±1.0 h per day in lean, Class I, Class II and Class III individuals) and more time in sedentary behaviors. There was no indication of metabolic efficiency in even the severely obese, as adjusted RMR was similar across all groups. The higher AEE observed in the obese is consistent with a higher cost of activities due to higher body weight. However, the magnitude of the higher AEE (20-25% higher in obese individuals) is lower than expected (weight approximately 100% higher in Class III individuals). Confirming a lower volume of physical activity in the obese, the total time spent in moderate-to-vigorous physical activity and average daily metabolic equivalent of task level were lower with increasing obesity. These findings demonstrate that high body weight in obese individuals leads to a high TDEE and AEE, which masks the fact that they are less physically active, which can be influenced by duration or intensity of activity, than in lean individuals.

  11. Energy monitoring system based on human activity in the workplace

    NASA Astrophysics Data System (ADS)

    Mustafa, Nur Hanim; Husain, Mohd Nor; Aziz, Mohamad Zoinol Abidin Abdul; Othman, Mohd Azlishah; Malek, Fareq

    2015-05-01

    Human behaviors always related to day routine activities in a smart house directly give the significant factor to manage energy usage in human life. An Addition that, the factor will contribute to the best efficiency of the system. This paper will focus on the monitoring efficiency based on duration time in office hours around 8am until 5pm which depend on human behavior at working place. Besides that, the correlation coefficient method is used to show the relation between energy consumption and energy saving based on the total hours of time energy spent. In future, the percentages of energy monitoring system usage will be increase to manage energy saving based on human behaviors. This scenario will help to see the human activity in the workplace in order to get the energy saving and support world green environment.

  12. NREL to Host Range of Activities for Energy Awareness Month

    Science.gov Websites

    Host Range of Activities for Energy Awareness Month Events devoted to energy savings Golden, Colo., Sept. 20, 2000 - Visitors will get an inside look at advanced energy technologies and learn tips for cutting utility bills when the U.S. Department of Energy's National Renewable Energy

  13. Avalanche photodiode for measurement of low-energy electrons

    NASA Astrophysics Data System (ADS)

    Ogasawara, K.; Asamura, K.; Mukai, T.; Saito, Y.

    2005-06-01

    We report on the performance of an Avalanche Photodiode (APD) produced by Hamamatsu Photonics Co. Ltd. (Type Z7966-20) for measurements of low energy electrons. We have set up an electron gun, which can generate a 1-20 keV electron beam impinging onto the APD in a vacuum chamber. The result shows that the pulse height distribution (PHD) of the APD signal exhibits a significant peak for electrons with energies above 8 keV, and the variation of the PHD peak shows a good linearity with the energy of incident electrons. The energy resolution is quite good, though it slightly depends on the electron energy. In the case of low-energies (lower than 10 keV), the pulse height distribution has a characteristic tail on the low energy side, and the energy resolution becomes a little worse. The position of the peak appears on a slightly lower channel than is expected from data at higher energies (near 20 keV). Qualitatively, the low-energy tail is caused by the dead-layer on the surface of the device. The nonlinearity and the worse resolution of the peaks for higher energy electrons may have resulted from a space-charge effect due to created e-h pairs. For a quantitative understanding, we have made a Monte Carlo particle simulation of charge transport and collection inside the APD.

  14. Activation energy of extracellular enzymes in soils from different biomes.

    PubMed

    Steinweg, J Megan; Jagadamma, Sindhu; Frerichs, Joshua; Mayes, Melanie A

    2013-01-01

    Enzyme dynamics are being incorporated into soil carbon cycling models and accurate representation of enzyme kinetics is an important step in predicting belowground nutrient dynamics. A scarce number of studies have measured activation energy (Ea) in soils and fewer studies have measured Ea in arctic and tropical soils, or in subsurface soils. We determined the Ea for four typical lignocellulose degrading enzymes in the A and B horizons of seven soils covering six different soil orders. We also elucidated which soil properties predicted any measurable differences in Ea. β-glucosidase, cellobiohydrolase, phenol oxidase and peroxidase activities were measured at five temperatures, 4, 21, 30, 40, and 60°C. Ea was calculated using the Arrhenius equation. β-glucosidase and cellobiohydrolase Ea values for both A and B horizons in this study were similar to previously reported values, however we could not make a direct comparison for B horizon soils because of the lack of data. There was no consistent relationship between hydrolase enzyme Ea and the environmental variables we measured. Phenol oxidase was the only enzyme that had a consistent positive relationship between Ea and pH in both horizons. The Ea in the arctic and subarctic zones for peroxidase was lower than the hydrolases and phenol oxidase values, indicating peroxidase may be a rate limited enzyme in environments under warming conditions. By including these six soil types we have increased the number of soil oxidative enzyme Ea values reported in the literature by 50%. This study is a step towards better quantifying enzyme kinetics in different climate zones.

  15. Optimization based on benefit of regional energy suppliers of distributed generation in active distribution network

    NASA Astrophysics Data System (ADS)

    Huo, Xianxu; Li, Guodong; Jiang, Ling; Wang, Xudong

    2017-08-01

    With the development of electricity market, distributed generation (DG) technology and related policies, regional energy suppliers are encouraged to build DG. Under this background, the concept of active distribution network (ADN) is put forward. In this paper, a bi-level model of intermittent DG considering benefit of regional energy suppliers is proposed. The objective of the upper level is the maximization of benefit of regional energy suppliers. On this basis, the lower level is optimized for each scene. The uncertainties of DG output and load of users, as well as four active management measures, which include demand-side management, curtailing the output power of DG, regulating reactive power compensation capacity and regulating the on-load tap changer, are considered. Harmony search algorithm and particle swarm optimization are combined as a hybrid strategy to solve the model. This model and strategy are tested with IEEE-33 node system, and results of case study indicate that the model and strategy successfully increase the capacity of DG and benefit of regional energy suppliers.

  16. Incorporating physical activity measures into environmental monitoring of national parks: an example from Yosemite.

    PubMed

    Walden-Schreiner, Chelsey; Leung, Yu-Fai; Floyd, Myron F

    2014-09-01

    To address increasing prevalence of obesity and associated chronic disease, recent national initiatives have called upon federal agencies to promote healthy lifestyles and provide opportunities for physical activity. In response, the U.S. National Park Service has developed strategies promoting health through physical activity in addition to its well-established biodiversity and landscape conservation mission. Incorporating physical activity measures with routine environmental monitoring would help identify areas where parks can promote active pursuits with minimal environmental impact. This study provides one example of how protocols developed for visitor and environmental monitoring can generate data to evaluate physical activity. Researchers implemented an observational study in high-use meadows of Yosemite National Park during the summer of 2011. Variables measured include the spatial location of visitors and activity type. Metabolic equivalents (METs) were assigned to activity categories and analyzed for average energy expenditure. Mean METs values indicated sedentary to light physical activity across the meadows, with greater means in areas with boardwalks or paved pathways. Data leveraged in this study provide park managers an example of adapting existing monitoring programs to incorporate indicators relevant to physical activity evaluation and how physical activity may impact resource conditions in national parks.

  17. Highlands County Energy Education Activities--High School Level.

    ERIC Educational Resources Information Center

    Allen, Rodney F., Ed.

    Presented are five instructional units, developed by the Tri-County Teacher Education Center, for the purpose of educating secondary school students on Florida's unique energy problems. Unit one provides a series of value clarification and awareness activities as an introduction to energy. Unit two uses mathematics exercises to examine energy…

  18. Fat to muscle ratio measurements with dual energy x-ray absorbtiometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, A.; Luo, J.; Wang, A.

    Accurate measurement of the fat-to-muscle ratio in animal model is important for obesity research. In addition, an efficient way to measure the fat to muscle ratio in animal model using dual-energy absorptiometry is presented in this paper. A radioactive source exciting x-ray fluorescence from a target material is used to provide the two x-ray energies needed. The x-rays, after transmitting through the sample, are measured with an energy-sensitive Ge detector. Phantoms and specimens were measured. The results showed that the method was sensitive to the fat to muscle ratios with good linearity. A standard deviation of a few percent inmore » the fat to muscle ratio could be observed with the x-ray dose of 0.001 mGy.« less

  19. Fat to muscle ratio measurements with dual energy x-ray absorbtiometry

    DOE PAGES

    Chen, A.; Luo, J.; Wang, A.; ...

    2015-03-14

    Accurate measurement of the fat-to-muscle ratio in animal model is important for obesity research. In addition, an efficient way to measure the fat to muscle ratio in animal model using dual-energy absorptiometry is presented in this paper. A radioactive source exciting x-ray fluorescence from a target material is used to provide the two x-ray energies needed. The x-rays, after transmitting through the sample, are measured with an energy-sensitive Ge detector. Phantoms and specimens were measured. The results showed that the method was sensitive to the fat to muscle ratios with good linearity. A standard deviation of a few percent inmore » the fat to muscle ratio could be observed with the x-ray dose of 0.001 mGy.« less

  20. Energy Conservation Education for New York State. Interdisciplinary Learning Activities. Grades 7-12.

    ERIC Educational Resources Information Center

    New York State Education Dept., Albany.

    Provided in this document are 18 energy conservation activities designed to supplement regular classroom learning activities. A matrix correlating activity number with grade level and subject areas is included. Titles of activities are: puzzles; energy quiz; energy-related careers; reading a meter; trading calories for kilo-watts; conserving home…

  1. Residential energy conservation measures: a penny saved is a penny earned

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Finklea, E.A.; Treiber, M.P.

    The authors are not suggesting that conservation alone will end our dependence on foreign oil. The focus is on basic household energy-conservation measures because they are technically simple, inexpensive, and available compared to more advanced energy-efficiency technologies (e.g., architectural designs and passive solar devices), or to alternative production technologies (e.g., photovoltaics and synthetic fuels). The social, institutional, and economic obstacles to implementing these basic measures are analyzed, and suggestions offered for overcoming these obstacles. During the Carter Administration, Congress enacted four laws to encourage the installation of household energy conservation measures. The laws provide: (1) tax credits for energy conservationmore » expenditures; (2) conservation investment subsidies for low income homeowners; and require: (3) natural gas and electric utilities to implement residential energy conservation programs for their customers; and (4) the federal government to provide loan subsidies for household energy-conservation investments through a conservation bank. The potential effectiveness of these federal programs are analyzed. President Reagan's advisers have indicated that the new administration will place greater emphasis on energy production and less emphasis on conservation. Consequently, the effectiveness of these programs may depend on the priority given them by the Reagan administration.« less

  2. School Energy Management: An Analysis of Energy Conservation Measures under the Schools and Hospitals Program.

    ERIC Educational Resources Information Center

    Hansen (Shirley J.) Associates, Inc., Lake Jackson, TX.

    This report analyzes a 1981 survey of public school districts receiving energy conservation measure (ECM) grants under the National Energy Conservation Policy Act, Title III, Cycle 1. The report contains charts of data, analyses of projects, and sections presenting study design, data treatment, findings, and conclusions. The survey's purpose was…

  3. New inferences from spectral seismic energy measurement of a link between regional seismicity and volcanic activity at Mt. Etna, Italy

    NASA Astrophysics Data System (ADS)

    Ortiz, R.; Falsaperla, S.; Marrero, J. M.; Messina, A.

    2009-04-01

    The existence of a relationship between regional seismicity and changes in volcanic activity has been the subject of several studies in the last years. Generally, activity in basaltic volcanoes such as Villarica (Chile) and Tungurahua (Ecuador) shows very little changes after the occurrence of regional earthquakes. In a few cases volcanic activity has changed before the occurrence of regional earthquakes, such as observed at Teide, Tenerife, in 2004 and 2005 (Tárraga et al., 2006). In this paper we explore the possible link between regional seismicity and changes in volcanic activity at Mt. Etna in 2006 and 2007. On 24 November, 2006 at 4:37:40 GMT an earthquake of magnitude 4.7 stroke the eastern coast of Sicily. The epicenter was localized 50 km SE of the south coast of the island, and at about 160 km from the summit craters of Mt. Etna. The SSEM (Spectral Seismic Energy Measurement) of the seismic signal at stations at 1 km and 6 km from the craters highlights that four hours before this earthquake the energy associated with volcanic tremor increased, reached a maximum, and finally became steady when the earthquake occurred. Conversely, neither before nor after the earthquake, the SSEM of stations located between 80 km and 120 km from the epicentre and outside the volcano edifice showed changes. On 5 September, 2007 at 21:24:13 GMT an earthquake of magnitude 3.2 and 7.9 km depth stroke the Lipari Island, at the north of Sicily. About 38 hours before the earthquake occurrence, there was an episode of lava fountain lasting 20 hours at Etna volcano. The SSEM of the seismic signal recorded during the lava fountain at a station located at 6 km from the craters highlights changes heralding this earthquake ten hours before its occurrence using the FFM method (e.g., Voight, 1988; Ortiz et al., 2003). A change in volcanic activity - with the onset of ash emission and Strombolian explosions - was observed a couple of hours before the occurrence of the regional

  4. Prospects for measuring the 229Th isomer energy using a metallic magnetic microcalorimeter.

    PubMed

    Kazakov, G A; Schauer, V; Schwestka, J; Stellmer, S P; Sterba, J H; Fleischmann, A; Gastaldo, L; Pabinger, A; Enss, C; Schumm, T

    2014-01-21

    The Thorium-229 isotope features a nuclear isomer state with an extremely low energy. The currently most accepted energy value, 7.8±0.5 eV, was obtained from an indirect measurement using a NASA x-ray microcalorimeter with an instrumental resolution 26 eV. We study, how state-of-the-art magnetic metallic microcalorimeters with an energy resolution down to a few eV can be used to measure the isomer energy. In particular, resolving the 29.18 keV doublet in the γ-spectrum following the α-decay of Uranium-233, corresponding to the decay into the ground and isomer state, allows to measure the isomer transition energy without additional theoretical input parameters, and increase the energy accuracy. We study the possibility of resolving the 29.18 keV line as a doublet and the dependence of the attainable precision of the energy measurement on the signal and background count rates and the instrumental resolution.

  5. Prospects for measuring the 229Th isomer energy using a metallic magnetic microcalorimeter☆

    PubMed Central

    Kazakov, G.A.; Schauer, V.; Schwestka, J.; Stellmer, S.P.; Sterba, J.H.; Fleischmann, A.; Gastaldo, L.; Pabinger, A.; Enss, C.; Schumm, T.

    2014-01-01

    The Thorium-229 isotope features a nuclear isomer state with an extremely low energy. The currently most accepted energy value, 7.8±0.5 eV, was obtained from an indirect measurement using a NASA x-ray microcalorimeter with an instrumental resolution 26 eV. We study, how state-of-the-art magnetic metallic microcalorimeters with an energy resolution down to a few eV can be used to measure the isomer energy. In particular, resolving the 29.18 keV doublet in the γ-spectrum following the α-decay of Uranium-233, corresponding to the decay into the ground and isomer state, allows to measure the isomer transition energy without additional theoretical input parameters, and increase the energy accuracy. We study the possibility of resolving the 29.18 keV line as a doublet and the dependence of the attainable precision of the energy measurement on the signal and background count rates and the instrumental resolution. PMID:25844000

  6. Energy Savings Lifetimes and Persistence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoffman, Ian M.; Schiller, Steven R.; Todd, Annika

    2016-02-01

    This technical brief explains the concepts of energy savings lifetimes and savings persistence and discusses how program administrators use these factors to calculate savings for efficiency measures, programs and portfolios. Savings lifetime is the length of time that one or more energy efficiency measures or activities save energy, and savings persistence is the change in savings throughout the functional life of a given efficiency measure or activity. Savings lifetimes are essential for assessing the lifecycle benefits and cost effectiveness of efficiency activities and for forecasting loads in resource planning. The brief also provides estimates of savings lifetimes derived from amore » national collection of costs and savings for electric efficiency programs and portfolios.« less

  7. New Perspectives on Spontaneous Brain Activity: Dynamic Networks and Energy Matter.

    PubMed

    Tozzi, Arturo; Zare, Marzieh; Benasich, April A

    2016-01-01

    Spontaneous brain activity has received increasing attention as demonstrated by the exponential rise in the number of published article on this topic over the last 30 years. Such "intrinsic" brain activity, generated in the absence of an explicit task, is frequently associated with resting-state or default-mode networks (DMN)s. The focus on characterizing spontaneous brain activity promises to shed new light on questions concerning the structural and functional architecture of the brain and how they are related to "mind". However, many critical questions have yet to be addressed. In this review, we focus on a scarcely explored area, specifically the energetic requirements and constraints of spontaneous activity, taking into account both thermodynamical and informational perspectives. We argue that the "classical" definitions of spontaneous activity do not take into account an important feature, that is, the critical thermodynamic energetic differences between spontaneous and evoked brain activity. Spontaneous brain activity is associated with slower oscillations compared with evoked, task-related activity, hence it exhibits lower levels of enthalpy and "free-energy" (i.e., the energy that can be converted to do work), thus supporting noteworthy thermodynamic energetic differences between spontaneous and evoked brain activity. Increased spike frequency during evoked activity has a significant metabolic cost, consequently, brain functions traditionally associated with spontaneous activity, such as mind wandering, require less energy that other nervous activities. We also review recent empirical observations in neuroscience, in order to capture how spontaneous brain dynamics and mental function can be embedded in a non-linear dynamical framework, which considers nervous activity in terms of phase spaces, particle trajectories, random walks, attractors and/or paths at the edge of the chaos. This takes us from the thermodynamic free-energy, to the realm of "variational

  8. CMOS active pixel sensors response to low energy light ions

    NASA Astrophysics Data System (ADS)

    Spiriti, E.; Finck, Ch.; Baudot, J.; Divay, C.; Juliani, D.; Labalme, M.; Rousseau, M.; Salvador, S.; Vanstalle, M.; Agodi, C.; Cuttone, G.; De Napoli, M.; Romano, F.

    2017-12-01

    Recently CMOS active pixel sensors have been used in Hadrontherapy ions fragmentation cross section measurements. Their main goal is to reconstruct tracks generated by the non interacting primary ions or by the produced fragments. In this framework the sensors, unexpectedly, demonstrated the possibility to obtain also some informations that could contribute to the ion type identification. The present analysis shows a clear dependency in charge and number of pixels per cluster (pixels with a collected amount of charge above a given threshold) with both fragment atomic number Z and energy loss in the sensor. This information, in the FIRST (F ragmentation of I ons R elevant for S pace and T herapy) experiment, has been used in the overall particle identification analysis algorithm. The aim of this paper is to present the data analysis and the obtained results. An empirical model was developed, in this paper, that reproduce the cluster size as function of the deposited energy in the sensor.

  9. Radon measurement and mitigation activity in Finland.

    PubMed

    Valmari, T; Arvela, H; Reisbacka, H; Holmgren, O

    2014-07-01

    Radon prevention, measurement and mitigation activities have been increasing in Finland during the 2000s. Nowadays, many municipal authorities, especially those located in high-radon areas, require radon prevention measures. This has activated radon measurements. Owners of new houses having radon piping installed under the floor slab are the most active group to measure and reduce the found high-radon values. Their radon awareness is apparently better than on the average, and the existing piping makes it easier and cheaper to reduce the radon levels. Local campaigns involving invitation flyers mailed to the residents have been a cost-effective means to activate measurements of older houses. So far 116,611 dwellings in low-rise residential buildings have been measured. At least 15% of the 16,860 dwellings found to exceed the reference level of 400 Bq m(-3) had their indoor radon level reduced below that. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Resonance energy transfer between the active sites of creatine kinase from rabbit brain.

    PubMed

    Grossman, S H

    1990-09-03

    Resonance energy transfer was measured between the active site domains of the brain isozyme of creatine kinase (CK-BB). The reactive thiol near the active sites, one on each subunit of the dimeric protein, was derivatized using 5-[2-[iodoacetyl)amino)ethyl]aminonaphthalene-1-sulfonic acid (AED), 2-[4'-iodoacetamidoanilino]naphthalene-6-sulfonic acid (AANS) and 5-iodoacetamidofluorescein (AF). Suitable donor/acceptor protein conjugated hybrids were prepared by controlled kinetics producing CK-BB-AED/AF and CK-BB-AANS/AF. Transfer efficiencies, measured from the quenching of the donor lifetime and steady-state sensitized acceptor emission, ranged from 0.10 to 0.17. From determination of the donor/acceptor overlap integrals, donor quantum yields and attempts to delimit the orientation factor using steady-state and phase-resolved anisotropy measurements, it was found that a suitable estimate of the range between the active sites was between 45 and 57 A. This range is similar to that reported previously for the muscle isozyme of creatine kinase (Grossman, S.H. (1989) Biochemistry 28, 4894-4902) but is a significantly greater distance than detected for the hybrid, myocardial specific isozyme (Grossman, S.H. (1983) Biochemistry 22, 5369-5375).

  11. Technology for radiation efficiency measurement of high-power halogen tungsten lamp used in calibration of high-energy laser energy meter.

    PubMed

    Wei, Ji Feng; Hu, Xiao Yang; Sun, Li Qun; Zhang, Kai; Chang, Yan

    2015-03-20

    The calibration method using a high-power halogen tungsten lamp as a calibration source has many advantages such as strong equivalence and high power, so it is very fit for the calibration of high-energy laser energy meters. However, high-power halogen tungsten lamps after power-off still reserve much residual energy and continually radiate energy, which is difficult to be measured. Two measuring systems were found to solve the problems. One system is composed of an integrating sphere and two optical spectrometers, which can accurately characterize the radiative spectra and power-time variation of the halogen tungsten lamp. This measuring system was then calibrated using a normal halogen tungsten lamp made of the same material as the high-power halogen tungsten lamp. In this way, the radiation efficiency of the halogen tungsten lamp after power-off can be quantitatively measured. In the other measuring system, a wide-spectrum power meter was installed far away from the halogen tungsten lamp; thus, the lamp can be regarded as a point light source. The radiation efficiency of residual energy from the halogen tungsten lamp was computed on the basis of geometrical relations. The results show that the halogen tungsten lamp's radiation efficiency was improved with power-on time but did not change under constant power-on time/energy. All the tested halogen tungsten lamps reached 89.3% of radiation efficiency at 50 s after power-on. After power-off, the residual energy in the halogen tungsten lamp gradually dropped to less than 10% of the initial radiation power, and the radiation efficiency changed with time. The final total radiation energy was decided by the halogen tungsten lamp's radiation efficiency, the radiation efficiency of residual energy, and the total power consumption. The measuring uncertainty of total radiation energy was 2.4% (here, the confidence factor is two).

  12. Energy Efficiency Under Alternative Carbon Policies. Incentives, Measurement, and Interregional Effects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steinberg, Daniel C.; Boyd, Erin

    2015-08-28

    In this report, we examine and compare how tradable mass-based polices and tradable rate-based policies create different incentives for energy efficiency investments. Through a generalized demonstration and set of examples, we show that as a result of the output subsidy they create, traditional rate-based policies, those that do not credit energy savings from efficiency measures, reduce the incentive for investment in energy efficiency measures relative to an optimally designed mass-based policy or equivalent carbon tax. We then show that this reduced incentive can be partially addressed by modifying the rate-based policy such that electricity savings from energy efficiency measures aremore » treated as a source of zero-carbon generation within the framework of the standard, or equivalently, by assigning avoided emissions credit to the electricity savings at the rate of the intensity target. These approaches result in an extension of the output subsidy to efficiency measures and eliminate the distortion between supply-side and demand-side options for GHG emissions reduction. However, these approaches do not address electricity price distortions resulting from the output subsidy that also impact the value of efficiency measures. Next, we assess alternative approaches for crediting energy efficiency savings within the framework of a rate-based policy. Finally, we identify a number of challenges that arise in implementing a rate-based policy with efficiency crediting, including the requirement to develop robust estimates of electricity savings in order to assess compliance, and the requirement to track the regionality of the generation impacts of efficiency measures to account for their interstate effects.« less

  13. Measurements of high energy photons in Z-pinch experiments on primary test stand

    NASA Astrophysics Data System (ADS)

    Si, Fenni; Zhang, Chuanfei; Xu, Rongkun; Yuan, Xi; Huang, Zhanchang; Xu, Zeping; Ye, Fan; Yang, Jianlun; Ning, Jiamin; Hu, Qingyuan; Zhu, Xuebin

    2015-08-01

    High energy photons are measured for the first time in wire-array Z-pinch experiments on the Primary Test Stand (PTS) which delivers a current up to 8 MA with a rise time of 70 ns. A special designed detecting system composed of three types of detectors is used to measure the average energy, intensity, and pulse waveform of high energy photons. Results from Pb-TLD (thermoluminescence dosimeter) detector indicate that the average energy is 480 keV (±15%). Pulse shape of high energy photons is measured by the photodiode detector consisted of scintillator coupled with a photodiode, and it is correlated with soft x-ray power by the same timing signal. Intensity is measured by both TLD and the photodiode detector, showing good accordance with each other, and it is 1010 cm-2 (±20%) at 2 m in the horizontal direction. Measurement results show that high energy photons are mainly produced in pinch regions due to accelerated electrons. PTS itself also produces high energy photons due to power flow electrons, which is one order smaller in amplitude than those from pinch region.

  14. Measurements of high energy photons in Z-pinch experiments on primary test stand.

    PubMed

    Si, Fenni; Zhang, Chuanfei; Xu, Rongkun; Yuan, Xi; Huang, Zhanchang; Xu, Zeping; Ye, Fan; Yang, Jianlun; Ning, Jiamin; Hu, Qingyuan; Zhu, Xuebin

    2015-08-01

    High energy photons are measured for the first time in wire-array Z-pinch experiments on the Primary Test Stand (PTS) which delivers a current up to 8 MA with a rise time of 70 ns. A special designed detecting system composed of three types of detectors is used to measure the average energy, intensity, and pulse waveform of high energy photons. Results from Pb-TLD (thermoluminescence dosimeter) detector indicate that the average energy is 480 keV (±15%). Pulse shape of high energy photons is measured by the photodiode detector consisted of scintillator coupled with a photodiode, and it is correlated with soft x-ray power by the same timing signal. Intensity is measured by both TLD and the photodiode detector, showing good accordance with each other, and it is 10(10) cm(-2) (±20%) at 2 m in the horizontal direction. Measurement results show that high energy photons are mainly produced in pinch regions due to accelerated electrons. PTS itself also produces high energy photons due to power flow electrons, which is one order smaller in amplitude than those from pinch region.

  15. Measuring Physical Activity in a Cardiac Rehabilitation Population Using a Smartphone-Based Questionnaire

    PubMed Central

    Maddison, Ralph; Jiang, Yannan; Dalleck, Lance; Löf, Marie

    2013-01-01

    Background Questionnaires are commonly used to assess physical activity in large population-based studies because of their low cost and convenience. Many self-report physical activity questionnaires have been shown to be valid and reliable measures, but they are subject to measurement errors and misreporting, often due to lengthy recall periods. Mobile phones offer a novel approach to measure self-reported physical activity on a daily basis and offer real-time data collection with the potential to enhance recall. Objective The aims of this study were to determine the convergent validity of a mobile phone physical activity (MobilePAL) questionnaire against accelerometry in people with cardiovascular disease (CVD), and to compare how the MobilePAL questionnaire performed compared with the commonly used self-recall International Physical Activity Questionnaire (IPAQ). Methods Thirty adults aged 49 to 85 years with CVD were recruited from a local exercise-based cardiac rehabilitation clinic in Auckland, New Zealand. All participants completed a demographics questionnaire and underwent a 6-minute walk test at the first visit. Subsequently, participants were temporarily provided a smartphone (with the MobilePAL questionnaire preloaded that asked 2 questions daily) and an accelerometer, which was to be worn for 7 days. After 1 week, a follow-up visit was completed during which the smartphone and accelerometer were returned, and participants completed the IPAQ. Results Average daily physical activity level measured using the MobilePAL questionnaire showed moderate correlation (r=.45; P=.01) with daily activity counts per minute (Acc_CPM) and estimated metabolic equivalents (MET) (r=.45; P=.01) measured using the accelerometer. Both MobilePAL (beta=.42; P=.008) and age (beta=–.48, P=.002) were significantly associated with Acc_CPM (adjusted R2=.40). When IPAQ-derived energy expenditure, measured in MET-minutes per week (IPAQ_met), was considered in the predicted model

  16. The measurement of energy consumption by exercise bikes

    NASA Astrophysics Data System (ADS)

    Jwo, Ching-Song; Chien, Chao-Chun; Jeng, Lung-Yue

    2006-11-01

    This paper is intended as an investigation is that to measure the amount of energy consumption can be consumed by riding bikes and also could recycle the consuming energy during exercising. Exercisers ride the bicycle inputting the driving force through a compressor of refrigeration system, which can circulate the refrigerant in the system and calculate the calorific capacity from the spread of the condenser. In addition, we can make up chiller water in the evaporator. Experiments were performed to prove the hypotheses. Therefore, this experiment has designed the sports goods which reach the purpose of doing exercise, measuring accurately the consuming calorific capacity and having the function of making chiller water. After exercising, you can drink the water producing during exercise and apply on the system of air conditioner, which attains two objectives.

  17. Measuring physical activity environments: a brief history.

    PubMed

    Sallis, James F

    2009-04-01

    Physical activity is usually done in specific types of places, referred to as physical activity environments. These often include parks, trails, fitness centers, schools, and streets. In recent years, scientific interest has increased notably in measuring physical activity environments. The present paper provides an historical overview of the contributions of the health, planning, and leisure studies fields to the development of contemporary measures. The emphasis is on attributes of the built environment that can be affected by policies to contribute to the promotion of physical activity. Researchers from health fields assessed a wide variety of built environment variables expected to be related to recreational physical activity. Settings of interest were schools, workplaces, and recreation facilities, and most early measures used direct observation methods with demonstrated inter-observer reliability. Investigators from the city planning field evaluated aspects of community design expected to be related to people's ability to walk from homes to destinations. GIS was used to assess walkability defined by the 3Ds of residential density, land-use diversity, and pedestrian-oriented designs. Evaluating measures for reliability or validity was rarely done in the planning-related fields. Researchers in the leisure studies and recreation fields studied mainly people's use of leisure time rather than physical characteristics of parks and other recreation facilities. Although few measures of physical activity environments were developed, measures of aesthetic qualities are available. Each of these fields made unique contributions to the contemporary methods used to assess physical activity environments.

  18. Suprathermal plasma analyzer for the measurement of low-energy electron distribution in the ionosphere.

    PubMed

    Shimoyama, M; Oyama, K-I; Abe, T; Yau, A W

    2011-07-01

    It is commonly believed that an energy transfer from thermal to suprathermal electrons (energy budget of the ionosphere. However, observation of electron energy spectrum in this energy range is quite limited because of technical difficulties of measurement. We have developed an instrument to measure electron energy distribution from thermal to suprathermal energy continuously with high-energy resolution of about 0.15 eV. The measurement principle is based on the combination of a retarding potential analyzer with a channel electron multiplier (CEM) and the Druyvesteyn method, which derives energy distribution from the current-voltage characteristics. The capability of detecting plasma space potential enables absolute calibration of electron energy. The instrument with a small vacuum pump, which is required for the CEM to work in low-vacuum region, was first successfully tested by a sounding rocket S-310-37 in the ionospheric E region. The instrument is expected to provide new opportunities to measure energy distribution of thermal and non-thermal electrons in low-density plasma, where a Langmuir probe cannot measure electron temperature because of low plasma density.

  19. The Energy Spectra of Proton and Helium Measured from the ATIC Experiment

    NASA Technical Reports Server (NTRS)

    Ahn, H. S.; Seo, E. S.; Adams, J. H.; Bashindzhagyan, G. L.; Batkov, K. E.; Chang, J.; Christl, M.; Fazely, A. R.; Ganel, O.; Gunasingha, R. M.

    2004-01-01

    The Advanced Thin Ionization Calorimeter (ATIC) balloon experiment is designed to investigate the composition and energy spectra of cosmic rays at the highest energies currently accessible from direct measurements, the region up to 100 TeV. The instrument consists of a silicon matrix for charge measurement, a graphite target (0.75 nuclear interaction length) to induce hadronic fragmentation, 3 scintillator strip hodoscopes for triggering and helping reconstruct trajectory, and a BGO calorimeter (18 radiation lengths) to measure the energy of incident particles. ATIC had two successful Long Duration Balloon (LDB) flights from McMurdo, Antarctica: from 12/28/00 to 01/13/01 and from 12/29/02 to 01/18/03. We present the energy spectra of proton and helium extracted from the ATIC flights, over the energy range from 100 GeV to 100 TeV, and compare them with the results from other experiments at both the lower and higher energy ends.

  20. Changes in energy metabolism in relation to physical activity due to fermentable carbohydrates in group-housed growing pigs.

    PubMed

    Schrama, J W; Bakker, G C

    1999-12-01

    Fermentable nonstarch polysaccharides (dietary fiber) affect energy retention in group-housed growing pigs by reducing physical activity. This study assessed the effects of fermentation and bulkiness of dietary carbohydrates on physical activity in relation to energy metabolism. Eight clusters of 14 pigs were fed one of four diets in a 2x2 factorial arrangement. Factors included 1) gastrointestinal fermentation and 2) dietary bulkiness. Contrasts in fermentation were created by exchanging gelatinized maize starch with raw potato starch on a volume basis. Bulkiness was altered by adding 15% milled wheat straw to the diets. Apart from these differences, amounts of other dietary ingredients fed to the pigs were similar. Pigs were housed in groups. Nitrogen and energy balances were measured per cluster during a 14-d period. Dietary bulkiness did not affect ME intake, heat production, or energy retention. Metabolizability decreased when maize starch was replaced with raw potato starch (P< .01), resulting in a lower energy retention on the potato starch diets (P<.01). However, the lower ME intake on the potato diets was partially compensated by a reduced energy expenditure on physical activity (P< .01), which was 17.6% lower than that of pigs fed the maize starch diets. Dietary bulkiness did not affect physical activity. The effect of fiber-rich diets (nonstarch polysaccharides) on activity in growing group-housed pigs seems to be related to fermentation in the gastrointestinal tract, and not to bulkiness (volume).

  1. Validation of a physical activity questionnaire to measure the effect of mechanical strain on bone mass.

    PubMed

    Kemper, Han C G; Bakker, I; Twisk, J W R; van Mechelen, W

    2002-05-01

    Most of the questionnaires available to estimate the daily physical activity levels of humans are based on measuring the intensity of these activities as multiples of resting metabolic rate (METs). Metabolic intensity of physical activities is the most important component for evaluating effects on cardiopulmonary fitness. However, animal studies have indicated that for effects on bone mass the intensity in terms of energy expenditure (metabolic component) of physical activities is less important than the intensity of mechanical strain in terms of the forces by the skeletal muscles and/or the ground reaction forces. The physical activity questionnaire (PAQ) used in the Amsterdam Growth and Health Longitudinal Study (AGAHLS) was applied to investigate the long-term effects of habitual physical activity patterns during youth on health and fitness in later adulthood. The PAQ estimates both the metabolic components of physical activities (METPA) and the mechanical components of physical activities (MECHPA). Longitudinal measurements of METPA and MECHPA were made in a young population of males and females ranging in age from 13 to 32 years. This enabled evaluation of the differential effects of physical activities during adolescence (13-16 years), young adulthood (21-28 years), and the total period of 15 years (age 13-28 years) on bone mineral density (BMD) of the lumbar spine, as measured by dual-energy X-ray absorptiometry (DXA) in males (n = 139) and females (n = 163) at a mean age of 32 years. The PAQ used in the AGAHLS during adolescence (13-16 years) and young adulthood (21-28 years) has the ability to measure the physical activity patterns of both genders, which are important for the development of bone mass at the adult age. MECHPA is more important than METPA. The highest coefficient of 0.33 (p < 0.01) was between MECHPA measured over the total period of 15 years (13-28 years) and lumbar BMD at age 32 years. Only during adolescence (12-16 years) was METPA more

  2. Neutron activation measurements over an extremely wide dynamic range (invited) (abstract)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnes, C.W.

    1997-01-01

    The DT program at the Tokamak Fusion Test Reactor (TFTR) created requirements on 14 MeV neutron measurements to measure from 10{sup 6} n/cm{sup 2} (for triton burnup and Ohmic tritium plasmas) to {gt}10{sup 12} n/cm{sup 2} (characteristic of {gt}10 MW DT plasmas) with an accuracy of 7% (one-sigma).1 To maintain an absolute calibration over this dynamic range with active neutron detectors required one to go from some absolute standard at one fluence level to a measurement at a much higher fluence. Maintaining accuracy requires an extremely linear set of measurements not systematically affected over this dynamic range. Neutron activation canmore » provide such linearity when care is taken with a number of effects such as gamma-ray detection efficiency and sample contamination.2 Absolutely calibrated neutron yield measurements using dosimetric (well-known cross section) reactions with thin (low-mass) elemental foils is be described. This technique makes the detector comparison to an absolute standard of gamma-ray activity correspond to all neutron fluences by reducing the sample mass while keeping the activation detectors operating in a linear counting mode; i.e., low count rates which minimize pileup effects. The International Thermonuclear Experimental Reactor is projected to have 1000 s burn durations at fluxes of few 10{sup 13} n/cm{sup 2}s, or more neutron fluence {ital per second} than entire TFTR discharges. Extrapolating neutron activation to these higher fluences will require yet more care. Some of the issues at such high fluences will be discussed.3 The National Ignition Facility (NIF) is projected to yield 10 MJ of fusion energy, or up to 10{sup 12} n/cm{sup 2} at the vacuum vessel wall, similar to TFTR DT conditions. It is expected that much interesting physics will be performed at yields far less than those from ignition, covering an even greater dynamic range than needed on TFTR. Thin foil techniques do not have the sensitivity required at low fluences.« less

  3. Active Control by Conservation of Energy Concept

    NASA Technical Reports Server (NTRS)

    Maestrello, Lucio

    2000-01-01

    Three unrelated experiments are discussed; each was extremely sensitive to initial conditions. The initial conditions are the beginnings of the origins of the information that nonlinearity displays. Initial conditions make the phenomenon unstable and unpredictable. With the knowledge of the initial conditions, active control requires far less power than that present in the system response. The first experiment is on the control of shocks from an axisymmetric supersonic jet; the second, control of a nonlinear panel response forced by turbulent boundary layer and sound; the third, control of subharmonic and harmonics of a panel forced by sound. In all three experiments, control is achieved by redistribution of periodic energy response such that the energy is nearly preserved from a previous uncontrolled state. This type of active control improves the performance of the system being controlled.

  4. Measuring top-quark polarization in top-pair + missing-energy events.

    PubMed

    Berger, Edmond L; Cao, Qing-Hong; Yu, Jiang-Hao; Zhang, Hao

    2012-10-12

    The polarization of a top quark can be sensitive to new physics beyond the standard model. Since the charged lepton from top-quark decay is maximally correlated with the top-quark spin, it is common to measure the polarization from the distribution in the angle between the charged lepton and the top-quark directions. We propose a novel method based on the charged lepton energy fraction and illustrate the method with a detailed simulation of top-quark pairs produced in supersymmetric top squark pair production. We show that the lepton energy ratio distribution that we define is very sensitive to the top-quark polarization but insensitive to the precise measurement of the top-quark energy.

  5. First-principles definition and measurement of planetary electromagnetic-energy budget.

    PubMed

    Mishchenko, Michael I; Lock, James A; Lacis, Andrew A; Travis, Larry D; Cairns, Brian

    2016-06-01

    The imperative to quantify the Earth's electromagnetic-energy budget with an extremely high accuracy has been widely recognized but has never been formulated in the framework of fundamental physics. In this paper we give a first-principles definition of the planetary electromagnetic-energy budget using the Poynting-vector formalism and discuss how it can, in principle, be measured. Our derivation is based on an absolute minimum of theoretical assumptions, is free of outdated notions of phenomenological radiometry, and naturally leads to the conceptual formulation of an instrument called the double hemispherical cavity radiometer (DHCR). The practical measurement of the planetary energy budget would require flying a constellation of several dozen planet-orbiting satellites hosting identical well-calibrated DHCRs.

  6. First-principles definition and measurement of planetary electromagnetic-energy budget

    NASA Astrophysics Data System (ADS)

    Mishchenko, M. I.; James, L.; Lacis, A. A.; Travis, L. D.; Cairns, B.

    2016-12-01

    The imperative to quantify the Earth's electromagnetic-energy budget with an extremely high accuracy has been widely recognized but has never been formulated in the framework of fundamental physics. In this talk we give a first-principles definition of the planetary electromagnetic-energy budget using the Poynting-vector formalism and discuss how it can, in principle, be measured. Our derivation is based on an absolute minimum of theoretical assumptions, is free of outdated concepts of phenomenological radiometry, and naturally leads to the conceptual formulation of an instrument called the double hemispherical cavity radiometer (DHCR). The practical measurement of the planetary energy budget would require flying a constellation of several dozen planet-orbiting satellites hosting identical well-calibrated DHCRs.

  7. First-Principles Definition and Measurement of Planetary Electromagnetic-Energy Budget

    NASA Technical Reports Server (NTRS)

    Mishchenko, Michael I.; Lock, James A.; Lacis, Andrew A.; Travis, Larry D.; Cairns, Brian

    2016-01-01

    The imperative to quantify the Earths electromagnetic-energy budget with an extremely high accuracy has been widely recognized but has never been formulated in the framework of fundamental physics. In this paper we give a first-principles definition of the planetary electromagnetic-energy budget using the Poynting- vector formalism and discuss how it can, in principle, be measured. Our derivation is based on an absolute minimum of theoretical assumptions, is free of outdated notions of phenomenological radiometry, and naturally leads to the conceptual formulation of an instrument called the double hemispherical cavity radiometer (DHCR). The practical measurement of the planetary energy budget would require flying a constellation of several dozen planet-orbiting satellites hosting identical well-calibrated DHCRs.

  8. Comparison of two methods of measuring physical activity in South African older adults.

    PubMed

    Kolbe-Alexander, Tracy L; Lambert, Estelle V; Harkins, Judith Biletnikoff; Ekelund, Ulf

    2006-01-01

    The aim of this study was to assess the validity and reliability of the Yale Physical Activity Survey (YPAS) and the short version of the International Physical Activity Questionnaire (IPAQ) in older South African adults. The YPAS includes measures of weekly energy expenditure (EE) for housework, yard work, caregiving, exercise, and recreation. The IPAQ measures total time and EE during vigorous and moderate activity, walking, and sitting. The instruments were administered twice for test-retest reliability (men, n = 52, 68 +/- 5.4 years, and women, n = 70, 66 +/- 5.8 years). Data for criterion validity were obtained from accelerometers. YPAS reliability ranged from r = .44 to.80 for men and r = .59 to .99 for women (p < .0001). IPAQ reliability was lower for men (r = .29 to .76) than for women (r = .46 to .77). Criterion validity of the YPAS was .31 to .54 for men and .26 to .29 for women. The YPAS and short IPAQ had comparable results for reliability and criterion validity.

  9. Physical activity, energy intake, and obesity prevalence among urban and rural schoolchildren aged 11-12 years in Japan.

    PubMed

    Itoi, Aya; Yamada, Yosuke; Watanabe, Yoshiyuki; Kimura, Misaka

    2012-12-01

    The prevalence of childhood overweight and obesity has been shown to differ among regions, including rural-urban regional differences within nations. This study obtained simultaneous accelerometry-derived physical activity, 24 h activity, and food records to clarify the potential contributing factors to rural-urban differences in childhood overweight and obesity in Japan. Sixth-grade children (n = 227, 11-12 years old) from two urban elementary schools in Kyoto and four rural elementary schools in Tohoku participated in the study. The children were instructed to wear a pedometer that included a uniaxial accelerometer and, assisted by their parents, keep minute-by-minute 24 h activity and food records. For 12 children, the total energy expenditure was measured by the doubly labeled water method that was used to correct the Lifecorder-predicted activity energy expenditure and physical activity level. The overweight and obesity prevalence was significantly higher in rural than in urban children. The number of steps per day, activity energy expenditure, physical activity level, and duration of walking to school were significantly lower in rural than in urban children. In contrast, the reported energy intake did not differ significantly between the regions. The physical activity and duration of the walk to school were significantly correlated with body mass index. Rural children had a higher prevalence of overweight and obesity, and this may be at least partly caused by lower physical activity, especially less time spent walking to school, than urban children.

  10. Evaluating the species energy relationship with the newest measures of ecosystem energy: NDVI versus MODIS primary production

    Treesearch

    Linda B. Phillips; Andrew J. Hansen; Curtis H. Flather

    2008-01-01

    Ecosystem energy has been shown to be a strong correlate with biological diversity at continental scales. Early efforts to characterize this association used the normalized difference vegetation index (NDVI) to represent ecosystem energy. While this spectral vegetation index covaries with measures of ecosystem energy such as net primary production, the covariation is...

  11. The measurement of energy exchange in man: an analysis.

    PubMed

    Webb, P

    1980-06-01

    This report analyzes two kinds of studies of human energy balance; direct and indirect calorimetry for 24-hr periods, and complete measurements of food intake, waste, and tissue storage for 3 weeks and longer. Equations of energy balance are written to show that the daily quantity of metabolic energy, QM, is coupled with an unidentified quantity of unmeasured energy, QX, in order to make the equation balance. The equations challenge the assumed equivalence of direct and indirect calorimetry. The analysis takes the form of employing experimental data to calculate values for the arguable quantity, QX. Studies employing 24-hr direct calorimetry, 202 complete days, show that when food intake nearly matches QM, values for QX are small and probably insignificant, but when there is a large food deficit, large positive values for QX appear. Calculations are also made from studies of nutrient balance during prolonged overeating and undereating, and in nearly all cases there were large negative values for QX. In 52 sets of data from studies lasting 3 weeks or longer, where all the terms in the balance equation except QX were either directly measured or could be readily estimated, the average value for QX amounts to 705 kcal/day, or 27% of QM. A discussion of the nature of QX considers error and the noninclusion of small quantities like the energy of combustible gases, which are not thought to be sufficient to explain QX. It might represent the cost of mobilizing stored fuel, or of storing excess fuel, or it might represent a change in internal energy other than fuel stores, but none of these is thought to be likely. Finally, it is emphasized that entropy exchange in man as an open thermodynamic system is not presently included in the equations of energy balance, and perhaps it must be, even though it is not directly measurable. The significance of unmeasured energy is considered in light of the poor control of obesity, of the inability to predict weight change during

  12. Validation of the human activity profile questionnaire as a measure of physical activity levels in older community-dwelling women.

    PubMed

    Bastone, Alessandra de Carvalho; Moreira, Bruno de Souza; Vieira, Renata Alvarenga; Kirkwood, Renata Noce; Dias, João Marcos Domingues; Dias, Rosângela Corrêa

    2014-07-01

    The purpose of this study was to assess the validity of the Human Activity Profile (HAP) by comparing scores with accelerometer data and by objectively testing its cutoff points. This study included 120 older women (age 60-90 years). Average daily time spent in sedentary, moderate, and hard activity; counts; number of steps; and energy expenditure were measured using an accelerometer. Spearman rank order correlations were used to evaluate the correlation between the HAP scores and accelerometer variables. Significant relationships were detected (rho = .47-.75, p < .001), indicating that the HAP estimates physical activity at a group level well; however, scatterplots showed individual errors. Receiver operating characteristic curves were constructed to determine HAP cutoff points on the basis of physical activity level recommendations, and the cutoff points found were similar to the original HAP cutoff points. The HAP is a useful indicator of physical activity levels in older women.

  13. How Much Energy Can Be Stored in Solar Active Region Magnetic Fields?

    NASA Astrophysics Data System (ADS)

    Linker, J.; Downs, C.; Torok, T.; Titov, V. S.; Lionello, R.; Mikic, Z.; Riley, P.

    2015-12-01

    Major solar eruptions such as X-class flares and very fast coronal mass ejections usually originate in active regions on the Sun. The energy that powers these events is believed to be stored as free magnetic energy (energy above the potential field state) prior to eruption. While coronal magnetic fields are not in general force-free, active regions have very strong magnetic fields and at low coronal heights the plasma beta is therefore very small, making the field (in equilibrium) essentially force-free. The Aly-Sturrock theorem shows that the energy of a fully force-free field cannot exceed the energy of the so-called open field. If the theorem holds, this places an upper limit on the amount of free energy that can be stored: the maximum free energy (MFE) is the difference between the open field energy and the potential field energy of the active region. In thermodynamic MHD simulations of a major eruption (the July 14, 2000 'Bastille' day event) and a modest event (February 13, 2009, we have found that the MFE indeed bounds the energy stored prior to eruption. We compute the MFE for major eruptive events in cycles 23 and 24 to investigate the maximum amount of energy that can be stored in solar active regions.Research supported by AFOSR, NASA, and NSF.

  14. The aircraft energy efficiency active controls technology program

    NASA Technical Reports Server (NTRS)

    Hood, R. V., Jr.

    1977-01-01

    Broad outlines of the NASA Aircraft Energy Efficiency Program for expediting the application of active controls technology to civil transport aircraft are presented. Advances in propulsion and airframe technology to cut down on fuel consumption and fuel costs, a program for an energy-efficient transport, and integrated analysis and design technology in aerodynamics, structures, and active controls are envisaged. Fault-tolerant computer systems and fault-tolerant flight control system architectures are under study. Contracts with leading manufacturers for research and development work on wing-tip extensions and winglets for the B-747, a wing load alleviation system, elastic mode suppression, maneuver-load control, and gust alleviation are mentioned.

  15. Activity energy expenditure and change in body composition in late life123

    PubMed Central

    Everhart, James E; Anton, Stephen D; Schoeller, Dale A; Cummings, Steve R; Mackey, Dawn C; Delmonico, Matthew J; Bauer, Douglas C; Simonsick, Eleanor M; Colbert, Lisa H; Visser, Marjolein; Tylavsky, Frances; Newman, Anne B; Harris, Tamara B

    2009-01-01

    Background: Change in body composition, specifically loss of fat-free mass and gain in fat mass, in older adults is a major pathway leading to the onset of functional decline and physical disability. Objective: The objective was to determine the association of activity-related energy expenditure with change in body mass and composition among older men and women. Design: Total energy expenditure (TEE) was assessed over 2 wk by using the doubly labeled water method in 302 community-dwelling older adults aged 70–82 y. Resting metabolic rate (RMR) was measured by using indirect calorimetry, and the thermic effect of meals was estimated at 10% of TEE. Activity energy expenditure (AEE) was calculated as [TEE(0.9) − RMR]. Total body mass, fat-free mass (FFM), and fat mass (FM) were assessed by dual-energy X-ray absorptiometry annually over a mean (±SD) of 4.9 ± 1.3 y. Results: In multivariate models adjusted for baseline age, smoking status, and race, men and women had a decline (in kg/y) in body mass (men: −0.34, 95% CI: −0.71, 0.02; women: −0.45, 95% CI: −0.71, −0.19) and FFM (men: −0.48, 95% CI: −0.67, −0.29; women: −0.14, 95% CI: −0.026, −0.03). No changes (in kg/y) were observed in FM (men: 0.14, 95% CI: −0.10, 0.38; women: −0.28, 95% CI: −0.49, −0.07). In men and women, higher AEE at baseline was associated with greater FFM. The average change in these outcomes (ie, slope), however, was similar across tertiles of AEE. Conclusions: These data suggest that accumulated energy expenditure from all physical activities is associated with greater FFM, but the effect does not alter the trajectory of FFM change in late life. PMID:19740971

  16. Spectrum measurement with the Telescope Array Low Energy Extension (TALE) fluorescence detector

    NASA Astrophysics Data System (ADS)

    Zundel, Zachary James

    The Telescope Array (TA) experiment is the largest Ultra High Energy cosmic ray observatory in the northern hemisphere and is designed to be sensitive to cosmic ray air showers above 1018eV. Despite the substantial measurements made by TA and AUGER (the largest cosmic ray observatory in the southern hemisphere), there remains uncertainty about whether the highest energy cosmic rays are galactic or extragalactic in origin. Locating features in the cosmic ray energy spectrum below 1018eV that indicate a transition from galactic to extragalactic sources would clarify the interpretation of measurements made at the highest energies. The Telescope Array Low Energy Extension (TALE) is designed to extend the energy threshold of the TA observatory down to 1016.5eV in order to make such measurements. This dissertation details the construction, calibration, and operation of the TALE flu- orescence detector. A measurement of the flux of cosmic rays in the energy range of 1016.5 -- 1018.5eV is made using the monocular data set taken between September 2013 and January 2014. The TALE fluorescence detector observes evidence for a softening of the cosmic spectrum at 1017.25+/-0.5eV. The evidence of a change in the spectrum motivates continued study of 1016.5 -- 1018.5eV cosmic rays.

  17. The Energy Expenditure of an Activity-Promoting Video Game compared to Sedentary Video Games and TV Watching

    PubMed Central

    Mitre, Naim; Foster, Randal C; Lanningham-Foster, Lorraine; Levine, James A.

    2014-01-01

    Background Screen time continues to be a major contributing factor to sedentariness in children. There have been more creative approaches to increase physical over the last few years. One approach has been through the use of video games. In the present study we investigated the effect of television watching and the use of activity-promoting video games on energy expenditure and movement in lean and obese children. Our primary hypothesis was that energy expenditure and movement decreases while watching television, in lean and obese children. Our secondary hypothesis was that energy expenditure and movement increases when playing the same game with an activity-promoting video game console compared to a sedentary video game console, in lean and obese children. Methods Eleven boys (10 ± 1 year) and eight girls (9 ± 1 year) ranging in BMI from 14–29 kg/m2 (eleven lean and eight overweight or obese) were recruited. Energy expenditure and physical activity were measured while participants were watching television, playing a video game on a traditional sedentary video game console, and while playing the same video game on an activity-promoting video game (Nintendo Wii) console. Results Energy expenditure was significantly greater than television watching and playing video games on a sedentary video game console when children played the video game on the activity-promoting console(125.3 ± 38.2 Kcal/hr vs. 79.7 ± 20.1 and 79.4 ±15.7, P<0.0001, respectively). When examining movement with accelerometry, children moved significantly more when playing the video game on the Nintendo Wii console (p<0.0001). Conclusion The amount of movement and energy expenditure of television watching and playing video games on a sedentary video game console is not different. Activity-promoting video games have shown to increase movement, and be an important tool to raise energy expenditure by 50% when compared to sedentary activities of daily living. PMID:22145458

  18. Effects of Activation Energy to Transient Response of Semiconductor Gas Sensor

    NASA Astrophysics Data System (ADS)

    Fujimoto, Akira; Ohtani, Tatsuki

    The smell classifiable gas sensor will be desired for many applications such as gas detection alarms, process controls for food production and so on. We have tried to realize the sensor using transient responses of semiconductor gas sensor consisting of tin dioxide and pointed out that the sensor gave us different transient responses for kinds of gas. Results of model calculation showed the activation energy of chemical reaction on the sensor surface strongly depended on the transient response. We tried to estimate the activation energies by molecular orbital calculation with SnO2 Cluster. The results show that there is a liner relationship between the gradient of the transient responses and activation energies for carboxylic and alcoholic gases. Transient response will be predicted from activation energy in the same kind of gas and the smell discrimination by single semiconductor gas sensor will be realized by this relationship.

  19. Measurement of proteases using chemiluminescence-resonance-energy-transfer chimaeras between green fluorescent protein and aequorin.

    PubMed Central

    Waud, J P; Bermúdez Fajardo, A; Sudhaharan, T; Trimby, A R; Jeffery, J; Jones, A; Campbell, A K

    2001-01-01

    Homogeneous assays, without a separation step, are essential for measuring chemical events in live cells and for drug discovery screens, and are desirable for making measurements in cell extracts or clinical samples. Here we demonstrate the principle of chemiluminescence resonance energy transfer (CRET) as a homogeneous assay system, using two proteases as models, one extracellular (alpha-thrombin) and the other intracellular (caspase-3). Chimaeras were engineered with aequorin as the chemiluminescent energy donor and green fluorescent protein (GFP) or enhanced GFP as the energy acceptors, with a protease linker (6 or 18 amino acid residues) recognition site between the donor and acceptor. Flash chemiluminescent spectra (20--60 s) showed that the spectra of chimaeras matched GFP, being similar to that of luminous jellyfish, justifying their designation as 'Rainbow' proteins. Addition of the protease shifted the emission spectrum to that of aequorin in a time- and dose-dependent manner. Separation of the proteolysed fragments showed that the ratio of green to blue light matched the extent of proteolysis. The caspase-3 Rainbow protein was able to provide information on the specificity of caspases in vitro and in vivo. It was also able to monitor caspase-3 activation in cells provoked into apoptosis by staurosporine (1 or 2 microM). CRET can also monitor GFP fluor formation. The signal-to-noise ratio of our Rainbow proteins is superior to that of fluorescence resonance energy transfer, providing a potential platform for measuring agents that interact with the reactive site between the donor and acceptor. PMID:11463339

  20. The improved physical activity index for measuring physical activity in EPIC Germany.

    PubMed

    Wientzek, Angelika; Vigl, Matthäus; Steindorf, Karen; Brühmann, Boris; Bergmann, Manuela M; Harttig, Ulrich; Katzke, Verena; Kaaks, Rudolf; Boeing, Heiner

    2014-01-01

    In the European Investigation into Cancer and Nutrition study (EPIC), physical activity (PA) has been indexed as a cross-tabulation between PA at work and recreational activity. As the proportion of non-working participants increases, other categorization strategies are needed. Therefore, our aim was to develop a valid PA index for this population, which will also be able to express PA continuously. In the German EPIC centers Potsdam and Heidelberg, a clustered sample of 3,766 participants was re-invited to the study center. 1,615 participants agreed to participate and 1,344 participants were finally included in this study. PA was measured by questionnaires on defined activities and a 7-day combined heart rate and acceleration sensor. In a training sample of 433 participants, the Improved Physical Activity Index (IPAI) was developed. Its performance was evaluated in a validation sample of 911 participants and compared with the Cambridge Index and the Total PA Index. The IPAI consists of items covering five areas including PA at work, sport, cycling, television viewing, and computer use. The correlations of the IPAI with accelerometer counts in the training and validation sample ranged r = 0.40-0.43 and with physical activity energy expenditure (PAEE) r = 0.33-0.40 and were higher than for the Cambridge Index and the Total PA Index previously applied in EPIC. In non-working participants the IPAI showed higher correlations than the Cambridge Index and the Total PA Index, with r = 0.34 for accelerometer counts and r = 0.29 for PAEE. In conclusion, we developed a valid physical activity index which is able to express PA continuously as well as to categorize participants according to their PA level. In populations with increasing rates of non-working people the performance of the IPAI is better than the established indices used in EPIC.

  1. Energy and Cost Savings of Retro-Commissioning and Retrofit Measures for Large Office Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Weimin; Zhang, Jian; Moser, Dave

    2012-08-03

    This paper evaluates the energy and cost savings of seven retro-commissioning measures and 29 retrofit measures applicable to most large office buildings. The baseline model is for a hypothetical building with characteristics of large office buildings constructed before 1980. Each retro-commissioning measure is evaluated against the original baseline in terms of its potential of energy and cost savings while each retrofit measure is evaluated against the commissioned building. All measures are evaluated in five locations (Miami, Las Vegas, Seattle, Chicago and Duluth) to understand the impact of weather conditions on energy and cost savings. The results show that implementation ofmore » the seven operation and maintenance measures as part of a retro-commissioning process can yield an average of about 22% of energy use reduction and 14% of energy cost reduction. Widening zone temperature deadband, lowering VAV terminal minimum air flow set points and lighting upgrades are effective retrofit measures to be considered.« less

  2. Energy cost of isometric force production after active shortening in skinned muscle fibres.

    PubMed

    Joumaa, Venus; Fitzowich, Alex; Herzog, Walter

    2017-04-15

    The steady-state isometric force after active shortening of a skeletal muscle is lower than the purely isometric force at the corresponding length. This property of skeletal muscle is known as force depression. The purpose of this study was to investigate whether the energy cost of force production at the steady state after active shortening was reduced compared with the energy cost of force production for a purely isometric contraction performed at the corresponding length (same length, same activation). Experiments were performed in skinned fibres isolated from rabbit psoas muscle. Skinned fibres were actively shortened from an average sarcomere length of 3.0 µm to an average sarcomere length of 2.4 µm. Purely isometric reference contractions were performed at an average sarcomere length of 2.4 µm. Simultaneously with the force measurements, the ATP cost was measured during the last 30 s of isometric contractions using an enzyme-coupled assay. Stiffness was calculated during a quick stretch-release cycle of 0.2% fibre length performed once the steady state had been reached after active shortening and during the purely isometric reference contractions. Force and stiffness following active shortening were decreased by 10.0±1.8% and 11.0±2.2%, respectively, compared with the isometric reference contractions. Similarly, ATPase activity per second (not normalized to the force) showed a decrease of 15.6±3.0% in the force-depressed state compared with the purely isometric reference state. However, ATPase activity per second per unit of force was similar for the isometric contractions following active shortening (28.7±2.4 mmol l -1  mN -1  s mm 3 ) and the corresponding purely isometric reference contraction (30.9±2.8 mmol l -1  mN -1  s mm 3 ). Furthermore, the reduction in absolute ATPase activity per second was significantly correlated with force depression and stiffness depression. These results are in accordance with the idea that force

  3. Particle discrimination of NaI(Tl) scintillator under high-energy neutron field to measure the photon energy spectrum

    NASA Astrophysics Data System (ADS)

    Kamada, So; Takada, Masashi; Suzuki, Toshikazu

    2014-09-01

    Photons are measured separately from neutrons in high-energy neutron fields using a NaI(Tl) scintillator, 7.62 cm in diameter and 7.62 cm in length, combined with a pulse-shape discrimination method. The particle discrimination capability for this scintillator is confirmed using a time-of-flight method. Neutron fields were produced by irradiating Li targets with 40 and 80 MeV proton beams at the cyclotron facility in the National Institute of Radiological Sciences. Figures of merit corresponding to particle discrimination for the scintillator at the two neutron fields are improved with higher neutron energies. Photon energy spectra for energies over 6.5 MeV can be measured using the NaI(Tl) scintillator.

  4. The Interplay of Energy Balance and Daily Timing of Activity in a Subterranean Rodent: A Laboratory and Field Approach.

    PubMed

    Tachinardi, Patricia; Valentinuzzi, Verónica S; Oda, Gisele A; Buck, C Loren

    The tuco-tuco (Ctenomys aff. knighti) is among the rodent species known to be nocturnal under standard laboratory conditions and diurnal under natural conditions. The circadian thermoenergetics (CTE) hypothesis postulates that switches in activity timing are a response to energetic challenges; daytime activity reduces thermoregulatory costs by consolidating activity to the warmest part of the day. Studying wild animals under both captive and natural conditions can increase understanding of how temporal activity patterns are shaped by the environment and could serve as a test of the CTE hypothesis. We estimated the effects of activity timing on energy expenditure for the tuco-tuco by combining laboratory measurements of metabolic rate with environmental temperature records in both winter and summer. We showed that, in winter, there would be considerable energy savings if activity is allocated at least partially during daylight, lending support to the CTE hypothesis. In summer, the impact of activity timing on energy expenditure is small, suggesting that during this season other factors, such as predation risk, water balance, and social interaction, may have more important roles than energetics in the determination of activity time.

  5. Energy expenditure, spontaneous physical activity and with weight gain in kidney transplant recipients.

    PubMed

    Heng, Anne-Elisabeth; Montaurier, Christophe; Cano, Noël; Caillot, Nicolas; Blot, A; Meunier, Nathalie; Pereira, Bruno; Marceau, Geoffroy; Sapin, Vincent; Jouve, Christelle; Boirie, Yves; Deteix, Patrice; Morio, Beatrice

    2015-06-01

    Alterations in energy metabolism could trigger weight gain after renal transplantation. Nineteen transplanted non-diabetic men, 53 ± 1.6 years old, receiving calcineurin inhibitors but no corticosteroids were studied. They were compared with nine healthy men matched for height, age and lean body mass. Daily energy expenditure and its components (sleeping, basal and absorptive metabolic rates) were analyzed for 24 h in calorimetric chambers and for 4 days in free living conditions using calibrated accelerometry. Other variables known to influence energy expenditure were assessed: body composition, physical activity, 4-day food intake, drug consumption, serum C-reactive protein, interleukin-6, thyroid and parathyroid hormones, and epinephrine. Transplant recipients who gained more than 5% body weight after transplantation (n = 11, +11.0 ± 1.5 kg) were compared with those who did not (n = 8) and with the controls. Weight gain compared with non-weight gain patients and controls exhibited higher fat mass without change in lean body mass. Daily, sleeping and resting energy expenditure adjusted for lean body mass was significantly higher in non-weight gain (167.1 ± 4.2 kJ/kg/lean body mass/24 h, P < 0.05) compared with weight gain patients (147.4 ± 3.6) and controls (146.1 ± 4.6). Weight gain compared with controls and non-weight gain subjects had lower free living physical activity and a higher consumption of antihypertensive drugs and β-blockers. After kidney transplantation, weight gain patients were characterized by lower adjusted energy expenditure, reduced spontaneous physical activity but a more sedentary life style and a trend toward a higher energy intake explaining the reason they gained weight. The nWG KTR had increased resting and sleeping EE which protected them from weight gain. Such hypermetabolism was also observed in 24-h EE measurements. By comparison with the nWG patients, the WG transplant recipients were characterized by higher

  6. Optics measurement algorithms and error analysis for the proton energy frontier

    NASA Astrophysics Data System (ADS)

    Langner, A.; Tomás, R.

    2015-03-01

    Optics measurement algorithms have been improved in preparation for the commissioning of the LHC at higher energy, i.e., with an increased damage potential. Due to machine protection considerations the higher energy sets tighter limits in the maximum excitation amplitude and the total beam charge, reducing the signal to noise ratio of optics measurements. Furthermore the precision in 2012 (4 TeV) was insufficient to understand beam size measurements and determine interaction point (IP) β -functions (β*). A new, more sophisticated algorithm has been developed which takes into account both the statistical and systematic errors involved in this measurement. This makes it possible to combine more beam position monitor measurements for deriving the optical parameters and demonstrates to significantly improve the accuracy and precision. Measurements from the 2012 run have been reanalyzed which, due to the improved algorithms, result in a significantly higher precision of the derived optical parameters and decreased the average error bars by a factor of three to four. This allowed the calculation of β* values and demonstrated to be fundamental in the understanding of emittance evolution during the energy ramp.

  7. A framework for quantifying the impact of occupant behavior on energy savings of energy conservation measures

    DOE PAGES

    Sun, Kaiyu; Hong, Tianzhen

    2017-04-27

    To improve energy efficiency—during new buildings design or during a building retrofit—evaluating the energy savings potential of energy conservation measures (ECMs) is a critical task. In building retrofits, occupant behavior significantly impacts building energy use and is a leading factor in uncertainty when determining the effectiveness of retrofit ECMs. Current simulation-based assessment methods simplify the representation of occupant behavior by using a standard or representative set of static and homogeneous assumptions ignoring the dynamics, stochastics, and diversity of occupant's energy-related behavior in buildings. The simplification contributes to significant gaps between the simulated and measured actual energy performance of buildings. Thismore » paper presents a framework for quantifying the impact of occupant behaviors on ECM energy savings using building performance simulation. During the first step of the study, three occupant behavior styles (austerity, normal, and wasteful) were defined to represent different levels of energy consciousness of occupants regarding their interactions with building energy systems (HVAC, windows, lights and plug-in equipment). Next, a simulation workflow was introduced to determine a range of the ECM energy savings. Then, guidance was provided to interpret the range of ECM savings to support ECM decision making. Finally, a pilot study was performed in a real building to demonstrate the application of the framework. Simulation results show that the impact of occupant behaviors on ECM savings vary with the type of ECM. Occupant behavior minimally affects energy savings for ECMs that are technology-driven (the relative savings differ by less than 2%) and have little interaction with the occupants; for ECMs with strong occupant interaction, such as the use of zonal control variable refrigerant flow system and natural ventilation, energy savings are significantly affected by occupant behavior (the relative savings

  8. A framework for quantifying the impact of occupant behavior on energy savings of energy conservation measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Kaiyu; Hong, Tianzhen

    To improve energy efficiency—during new buildings design or during a building retrofit—evaluating the energy savings potential of energy conservation measures (ECMs) is a critical task. In building retrofits, occupant behavior significantly impacts building energy use and is a leading factor in uncertainty when determining the effectiveness of retrofit ECMs. Current simulation-based assessment methods simplify the representation of occupant behavior by using a standard or representative set of static and homogeneous assumptions ignoring the dynamics, stochastics, and diversity of occupant's energy-related behavior in buildings. The simplification contributes to significant gaps between the simulated and measured actual energy performance of buildings. Thismore » paper presents a framework for quantifying the impact of occupant behaviors on ECM energy savings using building performance simulation. During the first step of the study, three occupant behavior styles (austerity, normal, and wasteful) were defined to represent different levels of energy consciousness of occupants regarding their interactions with building energy systems (HVAC, windows, lights and plug-in equipment). Next, a simulation workflow was introduced to determine a range of the ECM energy savings. Then, guidance was provided to interpret the range of ECM savings to support ECM decision making. Finally, a pilot study was performed in a real building to demonstrate the application of the framework. Simulation results show that the impact of occupant behaviors on ECM savings vary with the type of ECM. Occupant behavior minimally affects energy savings for ECMs that are technology-driven (the relative savings differ by less than 2%) and have little interaction with the occupants; for ECMs with strong occupant interaction, such as the use of zonal control variable refrigerant flow system and natural ventilation, energy savings are significantly affected by occupant behavior (the relative savings

  9. Measurements of proton energy spectra using a radiochromic film stack

    NASA Astrophysics Data System (ADS)

    Filkins, T. M.; Steidle, Jessica; Ellison, D. M.; Steidle, Jeffrey; Freeman, C. G.; Padalino, S. J.; Fiksel, G.; Regan, S. P.; Sangster, T. C.

    2014-10-01

    The energy spectrum of protons accelerated from the rear-side of a thin foil illuminated with ultra-intense laser light from the OMEGA EP laser system at the University of Rochester's Laboratory for Laser Energetics (LLE) was measured using a stack of radiochromic film (RCF). The film stack consisted of four layers of Gafchromic HD-V2 film and four layers of Gafchromic MD-V2-55 film. Aluminum foils of various thicknesses were placed between each piece of RCF in the stack. This arrangement allowed protons with energies of 30 MeV to reach the back layer of RCF in the stack. The stack was placed in the detector plane of a Thomson parabola ion energy (TPIE) spectrometer. Each piece of film in the stack was scanned using a commercially available flat-bed scanner (Epson 10000XL). The resulting optical density was converted into proton fluence using an absolute calibration of the RCF obtained at the SUNY Geneseo 1.7 MV Pelletron accelerator laboratory. In these calibration measurements, the sensitivity of the radiochromic film was measured using monoenergetic protons produced by the accelerator. Details of the analysis procedure and the resulting proton energy spectra will be presented. Funded in part by a grant from the DOE through the Laboratory for Laser Energetics.

  10. Strain-dependent activation energy of shear transformation in metallic glasses

    NASA Astrophysics Data System (ADS)

    Xu, Bin; Falk, Michael; Li, Jinfu; Kong, Lingti

    2017-04-01

    Shear transformation (ST) plays a decisive role in determining the mechanical behavior of metallic glasses, which is believed to be a stress-assisted thermally activated process. Understanding the dependence in its activation energy on the stress imposed on the material is of central importance to model the deformation process of metallic glasses and other amorphous solids. Here a theoretical model is proposed to predict the variation of the minimum energy path (MEP) associated with a particular ST event upon further deformation. Verification based on atomistic simulations and calculations are also conducted. The proposed model reproduces the MEP and activation energy of an ST event under different imposed macroscopic strains based on a known MEP at a reference strain. Moreover, an analytical approach is proposed based on the atomistic calculations, which works well when the stress varies linearity along the MEP. These findings provide necessary background for understanding the activation processes and, in turn, the mechanical behavior of metallic glasses.

  11. Energy Conservation Activity Guide, Grades 9-12. Bulletin 1602.

    ERIC Educational Resources Information Center

    Fraser, Mollie; And Others

    As an interdisciplinary, non-sequential teaching guide, this publication was developed to increase awareness and understanding of the energy situation and to encourage individuals to become energy conservationists. Sections provide background information for the teacher followed by a variety of student activities using different subject areas for…

  12. The Atomic Energy Commission's Annual Report to Congress for 1960. Major Activities in the Atomic Energy Programs, January - December 1960

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCone, John A.

    1961-01-31

    The document covers activities for the period January - December 1960. The report consists of two parts: Part One, The Atomic Energy Industry in 1960 and Related Activities; and Part Two, Major Activities in Atomic Energy Programs. Twenty-one appendices are also included.

  13. Global Auroral Energy Deposition Compared with Magnetic Indices

    NASA Technical Reports Server (NTRS)

    Brittnacher, M. J.; Fillingim, M. O.; Elsen, R.; Parks, G. K.; Germany, G. A.; Spann, J. F., Jr.

    1997-01-01

    Measurement of the global rate of energy deposition in the ionosphere via auroral particle precipitation is one of the primary goals of the Polar UVI program and is an important component of the ISTP program. The instantaneous rate of energy deposition for the entire month of January 1997 has been calculated by applying models to the UVI images and is presented by Fillingim et al. in this session. Magnetic indices, such as Kp, AE, and Dst, which are sensitive to variations in magnetospheric current systems have been constructed from ground magnetometer measurements and employed as measures of activity. The systematic study of global energy deposition raises the possibility of constructing a global magnetospheric activity index explicitly based on particle precipitation to supplement magnetic indices derived from ground magnetometer measurements. The relationship between global magnetic activity as measured by these indices and the rate of total global energy loss due to precipitation is not known at present. We study the correlation of the traditional magnetic index of Kp for the month of January 1997 with the energy deposition derived from the UVI images. We address the question of whether the energy deposition through particle precipitation generally matches the Kp and AE indices, or the more exciting, but distinct, possibility that this particle-derived index may provide an somewhat independent measure of global magnetospheric activity that could supplement traditional magnetically-based activity indices.

  14. Effects of easy-to-use protein-rich energy bar on energy balance, physical activity and performance during 8 days of sustained physical exertion.

    PubMed

    Tanskanen, Minna M; Westerterp, Klaas R; Uusitalo, Arja L; Atalay, Mustafa; Häkkinen, Keijo; Kinnunen, Hannu O; Kyröläinen, Heikki

    2012-01-01

    Previous military studies have shown an energy deficit during a strenuous field training course (TC). This study aimed to determine the effects of energy bar supplementation on energy balance, physical activity (PA), physical performance and well-being and to evaluate ad libitum fluid intake during wintertime 8-day strenuous TC. Twenty-six men (age 20±1 yr.) were randomly divided into two groups: The control group (n = 12) had traditional field rations and the experimental (Ebar) group (n = 14) field rations plus energy bars of 4.1 MJ•day(-1). Energy (EI) and water intake was recorded. Fat-free mass and water loss were measured with deuterium dilution and elimination, respectively. The energy expenditure was calculated using the intake/balance method and energy availability as (EI/estimated basal metabolic rate). PA was monitored using an accelerometer. Physical performance was measured and questionnaires of upper respiratory tract infections (URTI), hunger and mood state were recorded before, during and after TC. Ebar had a higher EI and energy availability than the controls. However, decreases in body mass and fat mass were similar in both groups representing an energy deficit. No differences were observed between the groups in PA, water balance, URTI symptoms and changes in physical performance and fat-free mass. Ebar felt less hunger after TC than the controls and they had improved positive mood state during the latter part of TC while controls did not. Water deficit associated to higher PA. Furthermore, URTI symptoms and negative mood state associated negatively with energy availability and PA. An easy-to-use protein-rich energy bars did not prevent energy deficit nor influence PA during an 8-day TC. The high content of protein in the bars might have induced satiation decreasing energy intake from field rations. PA and energy intake seems to be primarily affected by other factors than energy supplementation such as mood state.

  15. Effects of Easy-to-Use Protein-Rich Energy Bar on Energy Balance, Physical Activity and Performance during 8 Days of Sustained Physical Exertion

    PubMed Central

    Tanskanen, Minna M.; Westerterp, Klaas R.; Uusitalo, Arja L.; Atalay, Mustafa; Häkkinen, Keijo; Kinnunen, Hannu O.; Kyröläinen, Heikki

    2012-01-01

    Background Previous military studies have shown an energy deficit during a strenuous field training course (TC). This study aimed to determine the effects of energy bar supplementation on energy balance, physical activity (PA), physical performance and well-being and to evaluate ad libitum fluid intake during wintertime 8-day strenuous TC. Methods Twenty-six men (age 20±1 yr.) were randomly divided into two groups: The control group (n = 12) had traditional field rations and the experimental (Ebar) group (n = 14) field rations plus energy bars of 4.1 MJ•day−1. Energy (EI) and water intake was recorded. Fat-free mass and water loss were measured with deuterium dilution and elimination, respectively. The energy expenditure was calculated using the intake/balance method and energy availability as (EI/estimated basal metabolic rate). PA was monitored using an accelerometer. Physical performance was measured and questionnaires of upper respiratory tract infections (URTI), hunger and mood state were recorded before, during and after TC. Results Ebar had a higher EI and energy availability than the controls. However, decreases in body mass and fat mass were similar in both groups representing an energy deficit. No differences were observed between the groups in PA, water balance, URTI symptoms and changes in physical performance and fat-free mass. Ebar felt less hunger after TC than the controls and they had improved positive mood state during the latter part of TC while controls did not. Water deficit associated to higher PA. Furthermore, URTI symptoms and negative mood state associated negatively with energy availability and PA. Conclusion An easy-to-use protein-rich energy bars did not prevent energy deficit nor influence PA during an 8-day TC. The high content of protein in the bars might have induced satiation decreasing energy intake from field rations. PA and energy intake seems to be primarily affected by other factors than energy supplementation such

  16. Study protocol of physical activity and sedentary behaviour measurement among schoolchildren by accelerometry--cross-sectional survey as part of the ENERGY-project.

    PubMed

    Yıldırım, Mine; Verloigne, Maïté; de Bourdeaudhuij, Ilse; Androutsos, Odysseas; Manios, Yannis; Felso, Regina; Kovács, Éva; Doessegger, Alain; Bringolf-Isler, Bettina; te Velde, Saskia J; Brug, Johannes; Chinapaw, Mai J M

    2011-03-25

    Physical activity and sedentary behaviour among children should be measured accurately in order to investigate their relationship with health. Accelerometry provides objective and accurate measurement of body movement, which can be converted to meaningful behavioural outcomes. The aim of this study was to evaluate the best evidence for the decisions on data collection and data processing with accelerometers among children resulting in a standardized protocol for use in the participating countries. This cross-sectional accelerometer study was conducted as part of the European ENERGY-project that aimed to produce an obesity prevention intervention among schoolchildren. Five countries, namely Belgium, Greece, Hungary, Switzerland and the Netherlands participated in the accelerometer study. We used three different Actigraph models--Actitrainers (triaxial), GT3Xs and GT1Ms. Children wore the device for six consecutive days including two weekend days. We selected an epoch length of 15 seconds. Accelerometers were placed at children's waist at the right side of the body in an elastic belt. In total, 1082 children participated in the study (mean age = 11.7 ± 0.75 y, 51% girls). Non-wearing time was calculated as periods of more than 20 minutes of consecutive zero counts. The minimum daily wearing time was set to 10 hours for weekdays and 8 hours for weekend days. The inclusion criterion for further analysis was having at least three valid weekdays and one valid weekend day. We selected a cut-point (count per minute (cpm)) of <100 cpm for sedentary behaviour, <3000 cpm for light, <5200 cpm for moderate, and >5200 cpm for vigorous physical activity. We also created time filters for school-time during data cleaning in order to explore school-time physical activity and sedentary behaviour patterns in particular. This paper describes the decisions for data collection and processing. Use of standardized protocols would ease future use of accelerometry and the comparability of

  17. Energy response corrections for profile measurements using a combination of different detector types.

    PubMed

    Wegener, Sonja; Sauer, Otto A

    2018-02-01

    Different detector properties will heavily affect the results of off-axis measurements outside of radiation fields, where a different energy spectrum is encountered. While a diode detector would show a high spatial resolution, it contains high atomic number elements, which lead to perturbations and energy-dependent response. An ionization chamber, on the other hand, has a much smaller energy dependence, but shows dose averaging over its larger active volume. We suggest a way to obtain spatial energy response corrections of a detector independent of its volume effect for profiles of arbitrary fields by using a combination of two detectors. Measurements were performed at an Elekta Versa HD accelerator equipped with an Agility MLC. Dose profiles of fields between 10 × 4 cm² and 0.6 × 0.6 cm² were recorded several times, first with different small-field detectors (unshielded diode 60012 and stereotactic field detector SFD, microDiamond, EDGE, and PinPoint 31006) and then with a larger volume ionization chamber Semiflex 31010 for different photon beam qualities of 6, 10, and 18 MV. Correction factors for the small-field detectors were obtained from the readings of the respective detector and the ionization chamber using a convolution method. Selected profiles were also recorded on film to enable a comparison. After applying the correction factors to the profiles measured with different detectors, agreement between the detectors and with profiles measured on EBT3 film was improved considerably. Differences in the full width half maximum obtained with the detectors and the film typically decreased by a factor of two. Off-axis correction factors outside of a 10 × 1 cm² field ranged from about 1.3 for the EDGE diode about 10 mm from the field edge to 0.7 for the PinPoint 31006 25 mm from the field edge. The microDiamond required corrections comparable in size to the Si-diodes and even exceeded the values in the tail region of the field. The SFD was found

  18. Online beam energy measurement of Beijing electron positron collider II linear accelerator

    NASA Astrophysics Data System (ADS)

    Wang, S.; Iqbal, M.; Liu, R.; Chi, Y.

    2016-02-01

    This paper describes online beam energy measurement of Beijing Electron Positron Collider upgraded version II linear accelerator (linac) adequately. It presents the calculation formula, gives the error analysis in detail, discusses the realization in practice, and makes some verification. The method mentioned here measures the beam energy by acquiring the horizontal beam position with three beam position monitors (BPMs), which eliminates the effect of orbit fluctuation, and is much better than the one using the single BPM. The error analysis indicates that this online measurement has further potential usage such as a part of beam energy feedback system. The reliability of this method is also discussed and demonstrated in this paper.

  19. Online beam energy measurement of Beijing electron positron collider II linear accelerator.

    PubMed

    Wang, S; Iqbal, M; Liu, R; Chi, Y

    2016-02-01

    This paper describes online beam energy measurement of Beijing Electron Positron Collider upgraded version II linear accelerator (linac) adequately. It presents the calculation formula, gives the error analysis in detail, discusses the realization in practice, and makes some verification. The method mentioned here measures the beam energy by acquiring the horizontal beam position with three beam position monitors (BPMs), which eliminates the effect of orbit fluctuation, and is much better than the one using the single BPM. The error analysis indicates that this online measurement has further potential usage such as a part of beam energy feedback system. The reliability of this method is also discussed and demonstrated in this paper.

  20. Energy balance in man measured by direct and indirect calorimetry.

    PubMed

    Webb, P; Annis, J F; Troutman, S J

    1980-06-01

    In six 24-hr measurements of energy balance, direct and indirect calorimetry agreed within +/-3%, which is probably the range of experimental error. But in seven other 24-hr periods there was disagreement in the range of 8 to 23%, and these were usually days when the subjects ate much less than they spent metabolically. Our direct calorimeter is an insulated, water cooled suit. Continous measurements of O2 consumption and CO2 production provided data on metabolic expenditure (M) by indirect calorimetry. The 24-hr values for M matched the energy losses within +/-60 kcal (+/-3% of M) in four men who rested all day and lay down to sleep at night. Similar agreement was seen in one of the four who worked on a treadmill for 4 hr and stayed busy all day. but in another energy losses were 342 kcal greater than M (10% of M). When the experiments gave values for M minus the losses greater than +/-60 kcal, this is called "unmeasured energy". In further experiments, two subjects stayed awake for 24 hr, and their unmeasured energies were 279 and 393 kcal. The same two men, eating sparingly, also worked for 24 hr so as to double their resting metabolic expenditures; the unmeasured energies were even larger, 380 and 958 kcal. When they repeated the 24 hr of mild work, but ate nearly as much as they spent metabolically, one man was near energy balance, while the other showed an unmeasured energy of -363 kcal. Little heat storage was evident in these experiments; therefore, heat balance was present and energy balance should have been present. In the group of 13 experiments, it appeared that the greater the food deficit, the larger was the unmeasured energy (excess of metabolic expenditure over loss of energy).

  1. Energy Intake and Energy Expenditure for Determining Excess Weight Gain in Pregnant Women

    PubMed Central

    Gilmore, L. Anne; Butte, Nancy F.; Ravussin, Eric; Han, Hongmei; Burton, Jeffrey H.; Redman, Leanne M.

    2016-01-01

    Objective To conduct a secondary analysis designed to test whether gestational weight gain is due to increased energy intake or adaptive changes in energy expenditures. Methods In this secondary analysis, energy intake and energy expenditure of 45 pregnant women (BMI 18.5–24.9 kg/m2, n=33 and BMI ≥ 25, n=12) were measured preconceptionally 22, and 36 weeks of gestation. Energy intake was calculated as the sum of total energy expenditure measured by doubly labeled water and energy deposition determined by the 4-compartment body composition model. Weight, body composition, and metabolic chamber measurement were completed preconceptionally, 9, 22, and 36 weeks of gestation. Basal metabolic rate was measured by indirect calorimetry in a room calorimeter and activity energy expenditure by doubly labeled water. Results Energy intake from 22 to 36 weeks of gestation was significantly higher in high gainers (n=19) (3437 ± 99 kcal/d) versus low + ideal gainers (n=26) (2687 ± 110 p< .001) within both BMI categories. Basal metabolic rate increased in proportion to gestational weight gain; however, basal metabolic rate adjusted for body composition changes with gestational weight gain was not significantly different between high gainers and low + ideal gainers (151 ± 33 vs. 129 ± 36 kcal/d; p=.66). Activity energy expenditure decreased throughout pregnancy in both groups (low + ideal gainers: −150 ± 70 kcal/d; p=.04 and high gainers: −230 ± 92 kcal/day; p=.01), but there was no difference between high gainers and low + ideal gainers (p=.49). Conclusion Interventions designed to increase adherence to the IOM guidelines for weight gain in pregnancy may have increased efficacy if focused on limiting energy intake while increasing nutrient density and maintaining levels of physical activity. PMID:27054928

  2. Quantum Tunneling Contribution for the Activation Energy in Microwave-Induced Reactions.

    PubMed

    Kuhnen, Carlos A; Dall'Oglio, Evandro L; de Sousa, Paulo T

    2017-08-03

    In this study, a quantum approach is presented to explain microwave-enhanced reaction rates by considering the tunneling effects in chemical reactions. In the Arrhenius equation, the part of the Hamiltonian relative to the interaction energy during tunneling, between the particle that tunnels and the electrical field defined in the medium, whose spatial component is specified by its rms value, is taken into account. An approximate evaluation of the interaction energy leads to a linear dependence of the effective activation energy on the applied field. The evaluation of the rms value of the field for pure liquids and reaction mixtures, through their known dielectric properties, leads to an appreciable reduction in the activation energies for the proton transfer process in these liquids. The results indicate the need to move toward the use of more refined methods of modern quantum chemistry to calculate more accurately field-induced reaction rates and effective activation energies.

  3. A Novel Method to Quantify Soil Aggregate Stability by Measuring Aggregate Bond Energies

    NASA Astrophysics Data System (ADS)

    Efrat, Rachel; Rawlins, Barry G.; Quinton, John N.; Watts, Chris W.; Whitmore, Andy P.

    2016-04-01

    Soil aggregate stability is a key indicator of soil quality because it controls physical, biological and chemical functions important in cultivated soils. Micro-aggregates are responsible for the long term sequestration of carbon in soil, therefore determine soils role in the carbon cycle. It is thus vital that techniques to measure aggregate stability are accurate, consistent and reliable, in order to appropriately manage and monitor soil quality, and to develop our understanding and estimates of soil as a carbon store to appropriately incorporate in carbon cycle models. Practices used to assess the stability of aggregates vary in sample preparation, operational technique and unit of results. They use proxies and lack quantification. Conflicting results are therefore drawn between projects that do not provide methodological or resultant comparability. Typical modern stability tests suspend aggregates in water and monitor fragmentation upon exposure to an un-quantified amount of ultrasonic energy, utilising a laser granulometer to measure the change in mean weight diameter. In this project a novel approach has been developed based on that of Zhu et al., (2009), to accurately quantify the stability of aggregates by specifically measuring their bond energies. The bond energies are measured operating a combination of calorimetry and a high powered ultrasonic probe, with computable output function. Temperature change during sonication is monitored by an array of probes which enables calculation of the energy spent heating the system (Ph). Our novel technique suspends aggregates in heavy liquid lithium heteropolytungstate, as opposed to water, to avoid exposing aggregates to an immeasurable disruptive energy source, due to cavitation, collisions and clay swelling. Mean weight diameter is measured by a laser granulometer to monitor aggregate breakdown after successive periods of calculated ultrasonic energy input (Pi), until complete dispersion is achieved and bond

  4. A framework for quantifying the impact of occupant behavior on energy savings of energy conservation measures

    DOE PAGES

    Sun, K; Hong, T

    2017-07-01

    © 2017 Elsevier B.V. To improve energy efficiency—during new buildings design or during a building retrofit—evaluating the energy savings potential of energy conservation measures (ECMs) is a critical task. In building retrofits, occupant behavior significantly impacts building energy use and is a leading factor in uncertainty when determining the effectiveness of retrofit ECMs. Current simulation-based assessment methods simplify the representation of occupant behavior by using a standard or representative set of static and homogeneous assumptions ignoring the dynamics, stochastics, and diversity of occupant's energy-related behavior in buildings. The simplification contributes to significant gaps between the simulated and measured actual energymore » performance of buildings. This study presents a framework for quantifying the impact of occupant behaviors on ECM energy savings using building performance simulation. During the first step of the study, three occupant behavior styles (austerity, normal, and wasteful) were defined to represent different levels of energy consciousness of occupants regarding their interactions with building energy systems (HVAC, windows, lights and plug-in equipment). Next, a simulation workflow was introduced to determine a range of the ECM energy savings. Then, guidance was provided to interpret the range of ECM savings to support ECM decision making. Finally, a pilot study was performed in a real building to demonstrate the application of the framework. Simulation results show that the impact of occupant behaviors on ECM savings vary with the type of ECM. Occupant behavior minimally affects energy savings for ECMs that are technology-driven (the relative savings differ by less than 2%) and have little interaction with the occupants; for ECMs with strong occupant interaction, such as the use of zonal control variable refrigerant flow system and natural ventilation, energy savings are significantly affected by occupant behavior

  5. Prior automatic posture and activity identification improves physical activity energy expenditure prediction from hip-worn triaxial accelerometry.

    PubMed

    Garnotel, M; Bastian, T; Romero-Ugalde, H M; Maire, A; Dugas, J; Zahariev, A; Doron, M; Jallon, P; Charpentier, G; Franc, S; Blanc, S; Bonnet, S; Simon, C

    2018-03-01

    Accelerometry is increasingly used to quantify physical activity (PA) and related energy expenditure (EE). Linear regression models designed to derive PAEE from accelerometry-counts have shown their limits, mostly due to the lack of consideration of the nature of activities performed. Here we tested whether a model coupling an automatic activity/posture recognition (AAR) algorithm with an activity-specific count-based model, developed in 61 subjects in laboratory conditions, improved PAEE and total EE (TEE) predictions from a hip-worn triaxial-accelerometer (ActigraphGT3X+) in free-living conditions. Data from two independent subject groups of varying body mass index and age were considered: 20 subjects engaged in a 3-h urban-circuit, with activity-by-activity reference PAEE from combined heart-rate and accelerometry monitoring (Actiheart); and 56 subjects involved in a 14-day trial, with PAEE and TEE measured using the doubly-labeled water method. PAEE was estimated from accelerometry using the activity-specific model coupled to the AAR algorithm (AAR model), a simple linear model (SLM), and equations provided by the companion-software of used activity-devices (Freedson and Actiheart models). AAR-model predictions were in closer agreement with selected references than those from other count-based models, both for PAEE during the urban-circuit (RMSE = 6.19 vs 7.90 for SLM and 9.62 kJ/min for Freedson) and for EE over the 14-day trial, reaching Actiheart performances in the latter (PAEE: RMSE = 0.93 vs. 1.53 for SLM, 1.43 for Freedson, 0.91 MJ/day for Actiheart; TEE: RMSE = 1.05 vs. 1.57 for SLM, 1.70 for Freedson, 0.95 MJ/day for Actiheart). Overall, the AAR model resulted in a 43% increase of daily PAEE variance explained by accelerometry predictions. NEW & NOTEWORTHY Although triaxial accelerometry is widely used in free-living conditions to assess the impact of physical activity energy expenditure (PAEE) on health, its precision and accuracy are often debated

  6. Validation and comparison of two methods to assess human energy expenditure during free-living activities.

    PubMed

    Anastasopoulou, Panagiota; Tubic, Mirnes; Schmidt, Steffen; Neumann, Rainer; Woll, Alexander; Härtel, Sascha

    2014-01-01

    The measurement of activity energy expenditure (AEE) via accelerometry is the most commonly used objective method for assessing human daily physical activity and has gained increasing importance in the medical, sports and psychological science research in recent years. The purpose of this study was to determine which of the following procedures is more accurate to determine the energy cost during the most common everyday life activities; a single regression or an activity based approach. For this we used a device that utilizes single regression models (GT3X, ActiGraph Manufacturing Technology Inc., FL., USA) and a device using activity-dependent calculation models (move II, movisens GmbH, Karlsruhe, Germany). Nineteen adults (11 male, 8 female; 30.4±9.0 years) wore the activity monitors attached to the waist and a portable indirect calorimeter (IC) as reference measure for AEE while performing several typical daily activities. The accuracy of the two devices for estimating AEE was assessed as the mean differences between their output and the reference and evaluated using Bland-Altman analysis. The GT3X overestimated the AEE of walking (GT3X minus reference, 1.26 kcal/min), walking fast (1.72 kcal/min), walking up-/downhill (1.45 kcal/min) and walking upstairs (1.92 kcal/min) and underestimated the AEE of jogging (-1.30 kcal/min) and walking upstairs (-2.46 kcal/min). The errors for move II were smaller than those for GT3X for all activities. The move II overestimated AEE of walking (move II minus reference, 0.21 kcal/min), walking up-/downhill (0.06 kcal/min) and stair walking (upstairs: 0.13 kcal/min; downstairs: 0.29 kcal/min) and underestimated AEE of walking fast (-0.11 kcal/min) and jogging (-0.93 kcal/min). Our data suggest that the activity monitor using activity-dependent calculation models is more appropriate for predicting AEE in daily life than the activity monitor using a single regression model.

  7. Youth Physical Activity Resource Use and Activity Measured by Accelerometry

    ERIC Educational Resources Information Center

    Maslow, Andra L.; Colabianchi, Natalie

    2011-01-01

    Objectives: To examine whether use of physical activity resources (e.g., parks) was associated with daily physical activity measured by accelerometry. Methods: One hundred eleven adolescents completed a travel diary with concurrent accelerometry. The main exposure was self-reported use of a physical activity resource (none /1 resources). The main…

  8. Measuring energy-saving retrofits: Experiences from the Texas LoanSTAR program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haberl, J.S.; Reddy, T.A.; Claridge, D.E.

    1996-02-01

    In 1988 the Governor`s Energy Management Center of Texas received approval from the US Department of Energy to establish a $98.6 million state-wide retrofit demonstration revolving loan program to fund energy-conserving retrofits in state, public school, and local government buildings. As part of this program, a first-of-its-kind, statewide Monitoring and Analysis Program (MAP) was established to verify energy and dollar savings of the retrofits, reduce energy costs by identifying operational and maintenance improvements, improve retrofit selection in future rounds of the LoanSTAR program, and initiate a data base of energy use in institutional and commercial buildings located in Texas. Thismore » report discusses the LoanSTAR MAP with an emphasis on the process of acquiring and analyzing data to measure savings from energy conservation retrofits when budgets are a constraint. This report includes a discussion of the program structure, basic measurement techniques, data archiving and handling, data reporting and analysis, and includes selected examples from LoanSTAR agencies. A summary of the program results for the first two years of monitoring is also included.« less

  9. Energy deposition rates by charged particles measured during the energy budget campaign

    NASA Technical Reports Server (NTRS)

    Urban, A.; Torkar, K. M.; Bjordal, J.; Lundblad, J. A.; Soraas, F.; Grandal, B.; Smith, L. G.; Ulwick, J. C.; Vancour, R. P.

    1982-01-01

    Measurements of the precipitation of electrons and positive ions (in the keV to MeV range) detected aboard eight rockets launched from Northern Scandinavia are reported together with corresponding satellite data. The downgoing integral fluxes indicate the temporal fluctuations during each flight. Height profiles of the energy deposition into the atmosphere at different levels of geomagnetic disturbance are given.

  10. Analysis of coals and biomass pyrolysis using the distributed activation energy model.

    PubMed

    Li, Zhengqi; Liu, Chunlong; Chen, Zhichao; Qian, Juan; Zhao, Wei; Zhu, Qunyi

    2009-01-01

    The thermal decomposition of coals and biomass was studied using thermogravimetric analysis with the distributed activation energy model. The integral method resulted in Datong bituminous coal conversions of 3-73% at activation energies of 100-486 kJ/mol. The corresponding frequency factors were e(19.5)-e(59.0)s(-1). Jindongnan lean coal conversions were 8-52% at activation energies of 100-462 kJ/mol. Their corresponding frequency factors were e(13.0)-e(55.8)s(-1). The conversion of corn-stalk skins were 1-84% at activation energies of 62-169 kJ/mol with frequency factors of e(10.8)-e(26.5)s(-1). Datong bituminous coal, Jindongnan lean coal and corn-stalk skins had approximate Gaussian distribution functions with linear ln k(0) to E relationships.

  11. 10 CFR 431.193 - Test procedures for measuring energy consumption of distribution transformers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... distribution transformers. 431.193 Section 431.193 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Distribution Transformers Test Procedures § 431.193 Test procedures for measuring energy consumption of distribution transformers. The test...

  12. 10 CFR 431.193 - Test procedures for measuring energy consumption of distribution transformers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... distribution transformers. 431.193 Section 431.193 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Distribution Transformers Test Procedures § 431.193 Test procedures for measuring energy consumption of distribution transformers. The test...

  13. 10 CFR 431.193 - Test procedures for measuring energy consumption of distribution transformers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... distribution transformers. 431.193 Section 431.193 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Distribution Transformers Test Procedures § 431.193 Test procedures for measuring energy consumption of distribution transformers. The test...

  14. 10 CFR 431.193 - Test procedures for measuring energy consumption of distribution transformers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... distribution transformers. 431.193 Section 431.193 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Distribution Transformers Test Procedures § 431.193 Test procedures for measuring energy consumption of distribution transformers. The test...

  15. 10 CFR 431.193 - Test procedures for measuring energy consumption of distribution transformers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... distribution transformers. 431.193 Section 431.193 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Distribution Transformers Test Procedures § 431.193 Test procedures for measuring energy consumption of distribution transformers. The test...

  16. A simple model of entropy relaxation for explaining effective activation energy behavior below the glass transition temperature.

    PubMed

    Bisquert, Juan; Henn, François; Giuntini, Jean-Charles

    2005-03-01

    Strong changes in relaxation rates observed at the glass transition region are frequently explained in terms of a physical singularity of the molecular motions. We show that the unexpected trends and values for activation energy and preexponential factor of the relaxation time tau, obtained at the glass transition from the analysis of the thermally stimulated current signal, result from the use of the Arrhenius law for treating the experimental data obtained in nonstationary experimental conditions. We then demonstrate that a simple model of structural relaxation based on a time dependent configurational entropy and Adam-Gibbs relaxation time is sufficient to explain the experimental behavior, without invoking a kinetic singularity at the glass transition region. The pronounced variation of the effective activation energy appears as a dynamic signature of entropy relaxation that governs the change of relaxation time in nonstationary conditions. A connection is demonstrated between the peak of apparent activation energy measured in nonequilibrium dielectric techniques, with the overshoot of the dynamic specific heat that is obtained in calorimetry techniques.

  17. A SOFTWARE TOOL TO COMPARE MEASURED AND SIMULATED BUILDING ENERGY PERFORMANCE DATA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maile, Tobias; Bazjanac, Vladimir; O'Donnell, James

    2011-11-01

    Building energy performance is often inadequate when compared to design goals. To link design goals to actual operation one can compare measured with simulated energy performance data. Our previously developed comparison approach is the Energy Performance Comparison Methodology (EPCM), which enables the identification of performance problems based on a comparison of measured and simulated performance data. In context of this method, we developed a software tool that provides graphing and data processing capabilities of the two performance data sets. The software tool called SEE IT (Stanford Energy Efficiency Information Tool) eliminates the need for manual generation of data plots andmore » data reformatting. SEE IT makes the generation of time series, scatter and carpet plots independent of the source of data (measured or simulated) and provides a valuable tool for comparing measurements with simulation results. SEE IT also allows assigning data points on a predefined building object hierarchy and supports different versions of simulated performance data. This paper briefly introduces the EPCM, describes the SEE IT tool and illustrates its use in the context of a building case study.« less

  18. High-precision measurement of the light response of BC-418 plastic scintillator to protons with energies from 100 keV to 10 MeV

    NASA Astrophysics Data System (ADS)

    Henzl, Vladimir; Daub, Brian; French, Jennifer; Matthews, June; Kovash, Michael; Wender, Stephen; Famiano, Michael; Koehler, Katrina; Yuly, Mark

    2010-11-01

    The determination of the light response of many organic scintillators to various types of radiation has been a subject of numerous experimental as well as theoretical studies in the past. But while the data on light response to particles with energies above 1 MeV are precise and abundant, the information on light response to very low energy particles (i.e. below 1 MeV) is scarce or completely missing. In this study we measured the light response of a BC-418 scintillator to protons with energies from 100 keV to 10 MeV. The experiment was performed at Weapons Neutron Research Facility at LANSCE, Los Alamos. The neutron beam from a spallation source is used to irradiate the active target made from BC-418 plastic scintillator. The recoiled protons detected in the active target are measured in coincidence with elastically scattered incident neutrons detected by and adjacent liquid scintillator. Time of flight of the incident neutron and the knowledge of scattering geometry allow for a kinematically complete and high-precision measurement of the light response as a function of the proton energy.

  19. Total energy expenditure in the Yakut (Sakha) of Siberia as measured by the doubly labeled water method.

    PubMed

    Snodgrass, J Josh; Leonard, William R; Tarskaia, Larissa A; Schoeller, Dale A

    2006-10-01

    Populations in transition to a Western lifestyle display increased incidences of obesity, type 2 diabetes, and other chronic diseases; the mechanisms responsible for these changes, however, remain incompletely understood. Although reduced physical activity has been implicated, few studies have accurately quantified energy expenditure in subsistence populations. The aim of the study was to examine the relation of total energy expenditure (TEE) and activity [physical activity level (PAL), activity energy expenditure (AEE), and weight-adjusted AEE (AEE/kg)] with body composition and lifestyle in the Yakut (Sakha), an indigenous high-latitude Siberian group. We measured TEE using doubly labeled water and resting metabolic rate using indirect calorimetry in 28 young adults (14 women and 14 men) from Berdygestiakh, Russia. The men had higher TEE (12,983 compared with 9620 kJ/d; P < 0.01), AEE (5248 compared with 3203 kJ/d; P < 0.05), AEE/kg (72.7 compared with 48.8 kJ . kg(-1) . d(-1); P < 0.05), and PAL (1.7 compared with 1.5; P = 0.09) than did the women, although this may reflect, in part, body size and composition differences. Overweight men and women had modestly higher TEEs than did lean participants; when adjusted for body size, activity levels were not significantly different between the groups. Persons with more traditional lifestyles had higher TEEs and PALs than did persons with more modernized lifestyles; this difference correlated with differences in participation in subsistence activities. Activity levels in the Yakut were lower than those in other subsistence groups, especially the women, and were not significantly different from those in persons in industrialized nations. Persons who participated in more subsistence activities and consumed fewer market foods had significantly higher activity levels.

  20. Advanced Active-Magnetic-Bearing Thrust-Measurement System

    NASA Technical Reports Server (NTRS)

    Imlach, Joseph; Kasarda, Mary; Blumber, Eric

    2008-01-01

    An advanced thrust-measurement system utilizes active magnetic bearings to both (1) levitate a floating frame in all six degrees of freedom and (2) measure the levitation forces between the floating frame and a grounded frame. This system was developed for original use in measuring the thrust exerted by a rocket engine mounted on the floating frame, but can just as well be used in other force-measurement applications. This system offers several advantages over prior thrust-measurement systems based on mechanical support by flexures and/or load cells: The system includes multiple active magnetic bearings for each degree of freedom, so that by selective use of one, some, or all of these bearings, it is possible to test a given article over a wide force range in the same fixture, eliminating the need to transfer the article to different test fixtures to obtain the benefit of full-scale accuracy of different force-measurement devices for different force ranges. Like other active magnetic bearings, the active magnetic bearings of this system include closed-loop control subsystems, through which the stiffness and damping characteristics of the magnetic bearings can be modified electronically. The design of the system minimizes or eliminates cross-axis force-measurement errors. The active magnetic bearings are configured to provide support against movement along all three orthogonal Cartesian axes, and such that the support along a given axis does not produce force along any other axis. Moreover, by eliminating the need for such mechanical connections as flexures used in prior thrust-measurement systems, magnetic levitation of the floating frame eliminates what would otherwise be major sources of cross-axis forces and the associated measurement errors. Overall, relative to prior mechanical-support thrust-measurement systems, this system offers greater versatility for adaptation to a variety of test conditions and requirements. The basic idea of most prior active

  1. Neutron spectral measurements in an intense photon field associated with a high-energy x-ray radiotherapy machine.

    PubMed

    Holeman, G R; Price, K W; Friedman, L F; Nath, R

    1977-01-01

    High-energy x-ray radiotherapy machines in the supermegavoltage region generate complex neutron energy spectra which make an exact evaluation of neutron shielding difficult. Fast neutrons resulting from photonuclear reactions in the x-ray target and collimators undergo successive collisions in the surrounding materials and are moderated by varying amounts. In order to examine the neutron radiation exposures quantitatively, the neutron energy spectra have been measured inside and outside the treatment room of a Sagittaire medical linear accelerator (25-MV x rays) located at Yale-New Haven Hospital. The measurements were made using a Bonner spectrometer consisting of 2-, 3-, 5-, 8-, 10- and 12-in.-diameter polyethylene spheres with 6Li and 7Li thermoluminescent dosimeter (TLD) chips at the centers, in addition to bare and cadmium-covered chips. The individual TLD chips were calibrated for neutron and photon response. The spectrometer was calibrated using a known PuBe spectrum Spectrometer measurements were made at Yale Electron Accelerator Laboratory and results compared with a neutron time-of-flight spectrometer and an activation technique. The agreement between the results from these independent methods is found to be good, except for the measurements in the direct photon beam. Quality factors have been inferred for the neutron fields inside and outside the treatment room. Values of the inferred quality factors fall primarily between 4 and 8, depending on location.

  2. Iowa Developed Energy Activity Sampler (IDEAS), Grades 7-12: Industrial Arts.

    ERIC Educational Resources Information Center

    Simonis, Doris G.

    Described is the Industrial Arts component of the Iowa Developed Energy Activity Sampler (IDEAS), a multidisciplinary energy education program designed for infusion into the curriculum of grades 7-12. Also included in the program are activity sets for Home Economics (SE 034 678), Language Arts (SE 034 680), Mathematics (SE 034 681), Science (SE…

  3. Measurement of the cleavage energy of graphite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Wen; Dai, Shuyang; Li, Xide

    Here, the basal plane cleavage energy (CE) of graphite is a key material parameter for understanding many of the unusual properties of graphite, graphene and carbon nanotubes. Nonetheless, a wide range of values for the CE has been reported and no consensus has yet emerged. Here we report the first direct, accurate experimental measurement of the CE of graphite using a novel method based on the self-retraction phenomenon in graphite. The measured value, 0.37±0.01 J m –2 for the incommensurate state of bicrystal graphite, is nearly invariant with respect to temperature (22 °C≤T≤198 °C) and bicrystal twist angle, and insensitivemore » to impurities from the atmosphere. The CE for the ideal ABAB graphite stacking, 0.39±0.02 J m –2, is calculated based on a combination of the measured CE and a theoretical calculation. These experimental measurements are also ideal for use in evaluating the efficacy of competing theoretical approaches.« less

  4. Measurement of the cleavage energy of graphite

    DOE PAGES

    Wang, Wen; Dai, Shuyang; Li, Xide; ...

    2015-08-28

    Here, the basal plane cleavage energy (CE) of graphite is a key material parameter for understanding many of the unusual properties of graphite, graphene and carbon nanotubes. Nonetheless, a wide range of values for the CE has been reported and no consensus has yet emerged. Here we report the first direct, accurate experimental measurement of the CE of graphite using a novel method based on the self-retraction phenomenon in graphite. The measured value, 0.37±0.01 J m –2 for the incommensurate state of bicrystal graphite, is nearly invariant with respect to temperature (22 °C≤T≤198 °C) and bicrystal twist angle, and insensitivemore » to impurities from the atmosphere. The CE for the ideal ABAB graphite stacking, 0.39±0.02 J m –2, is calculated based on a combination of the measured CE and a theoretical calculation. These experimental measurements are also ideal for use in evaluating the efficacy of competing theoretical approaches.« less

  5. High throughput measurement of metabolism in planarians reveals activation of glycolysis during regeneration

    PubMed Central

    Osuma, Edie A.; Riggs, Daniel W.; Gibb, Andrew A.

    2018-01-01

    Abstract Planarians are outstanding models for studying mechanisms of regeneration; however, there are few methods to measure changes in their metabolism. Examining metabolism in planarians is important because the regenerative process is dependent on numerous integrated metabolic pathways, which provide the energy required for tissue repair as well as the ability to synthesize the cellular building blocks needed to form new tissue. Therefore, we standardized an extracellular flux analysis method to measure mitochondrial and glycolytic activity in live planarians during normal growth as well as during regeneration. Small, uninjured planarians showed higher rates of oxygen consumption compared with large planarians, with no difference in glycolytic activity; however, glycolysis increased during planarian regeneration. Exposure of planarians to koningic acid, a specific inhibitor of glyceraldehyde‐3‐phosphate dehydrogenase, completely abolished extracellular acidification with little effect on oxygen consumption, which suggests that the majority of glucose catabolized in planarians is fated for aerobic glycolysis. These studies describe a useful method for measuring respiration and glycolysis in planarians and provide data implicating changes in glucose metabolism in the regenerative response. PMID:29721328

  6. Kinetic study of solid waste pyrolysis using distributed activation energy model.

    PubMed

    Bhavanam, Anjireddy; Sastry, R C

    2015-02-01

    The pyrolysis characteristics of municipal solid waste, agricultural residues such as ground nut shell, cotton husk and their blends are investigated using non-isothermal thermogravimetric analysis (TGA) with in a temperature range of 30-900 °C at different heating rates of 10 °C, 30 °C and 50 °C/min in inert atmosphere. From the thermograms obtained from TGA, it is observed that the maximum rate of degradation occurred in the second stage of the pyrolysis process for all the solid wastes. The distributed activation energy model (DAEM) is used to study the pyrolysis kinetics of the solid wastes. The kinetic parameters E (activation energy), k0 (frequency factor) are calculated from this model. It is found that the range of activation energies for agricultural residues are lower than the municipal solid waste. The activation energies for the municipal solid waste pyrolysis process drastically decreased with addition of agricultural residues. The proposed DAEM is successfully validated with TGA experimental data. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. World Energy Projection System Plus (WEPS ): Global Activity Module

    EIA Publications

    2016-01-01

    The World Energy Projection System Plus (WEPS ) is a comprehensive, mid?term energy forecasting and policy analysis tool used by EIA. WEPS projects energy supply, demand, and prices by country or region, given assumptions about the state of various economies, international energy markets, and energy policies. The Global Activity Module (GLAM) provides projections of economic driver variables for use by the supply, demand, and conversion modules of WEPS . GLAM’s baseline economic projection contains the economic assumptions used in WEPS to help determine energy demand and supply. GLAM can also provide WEPS with alternative economic assumptions representing a range of uncertainty about economic growth. The resulting economic impacts of such assumptions are inputs to the remaining supply and demand modules of WEPS .

  8. The Geography of Wind Energy: Problem Solving Activities.

    ERIC Educational Resources Information Center

    Lahart, David E.; Allen, Rodney F.

    1985-01-01

    Today there are many attempts to use wind machines to confront the increasing costs of electricity. Described are activities to help secondary students understand wind energy, its distribution, applications, and limitations. (RM)

  9. Review of Evaluation, Measurement and Verification Approaches Used to Estimate the Load Impacts and Effectiveness of Energy Efficiency Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Messenger, Mike; Bharvirkar, Ranjit; Golemboski, Bill

    Public and private funding for end-use energy efficiency actions is expected to increase significantly in the United States over the next decade. For example, Barbose et al (2009) estimate that spending on ratepayer-funded energy efficiency programs in the U.S. could increase frommore » $3.1 billion in 2008 to $$7.5 and 12.4 billion by 2020 under their medium and high scenarios. This increase in spending could yield annual electric energy savings ranging from 0.58% - 0.93% of total U.S. retail sales in 2020, up from 0.34% of retail sales in 2008. Interest in and support for energy efficiency has broadened among national and state policymakers. Prominent examples include {approx}$$18 billion in new funding for energy efficiency programs (e.g., State Energy Program, Weatherization, and Energy Efficiency and Conservation Block Grants) in the 2009 American Recovery and Reinvestment Act (ARRA). Increased funding for energy efficiency should result in more benefits as well as more scrutiny of these results. As energy efficiency becomes a more prominent component of the U.S. national energy strategy and policies, assessing the effectiveness and energy saving impacts of energy efficiency programs is likely to become increasingly important for policymakers and private and public funders of efficiency actions. Thus, it is critical that evaluation, measurement, and verification (EM&V) is carried out effectively and efficiently, which implies that: (1) Effective program evaluation, measurement, and verification (EM&V) methodologies and tools are available to key stakeholders (e.g., regulatory agencies, program administrators, consumers, and evaluation consultants); and (2) Capacity (people and infrastructure resources) is available to conduct EM&V activities and report results in ways that support program improvement and provide data that reliably compares achieved results against goals and similar programs in other jurisdictions (benchmarking). The National Action Plan for

  10. Energy expended playing video console games: an opportunity to increase children's physical activity?

    PubMed

    Maddison, Ralph; Mhurchu, Cliona Ni; Jull, Andrew; Jiang, Yannan; Prapavessis, Harry; Rodgers, Anthony

    2007-08-01

    This study sought to quantify the energy expenditure and physical activity associated with playing the "new generation" active and nonactive console-based video games in 21 children ages 10-14 years. Energy expenditure (kcal) derived from oxygen consumption (VO2) was continuously assessed while children played nonactive and active console video games. Physical activity was assessed continuously using the Actigraph accelerometer. Significant (p < .001) increases from baseline were found for energy expenditure (129-400%), heart rate (43-84%), and activity counts (122-1288 versus 0-23) when playing the active console video games. Playing active console video games over short periods of time is similar in intensity to light to moderate traditional physical activities such as walking, skipping, and jogging.

  11. Measuring the energy deposited by muon bundles of inclined EAS in the NEVOD-DECOR experiment

    NASA Astrophysics Data System (ADS)

    Kokoulin, R. P.; Bogdanov, A. G.; Barbashina, N. S.; Dushkin, L. I.; Kindin, V. V.; Kompaniets, K. G.; Mannocchi, G.; Petrukhin, A. A.; Saavedra, O.; Trinchero, G.; Khomyakov, V. A.; Khokhlov, S. S.; Chernov, D. V.; Shutenko, V. V.; Yurina, E. A.; Yashin, I. I.

    2018-01-01

    As part of an in-depth investigation of the muon excess observed in ultrahigh-energy cosmic rays, one needs to measure the energy characteristics of muon component of extensive air showers (EAS). The mean muon energy can be estimated from the energy deposited in the detector by the muon bundles. In the NEVOD-DECOR experiment, the local muon density and the shower-arrival direction are measured with a track-coordinate detector, and the deposited energy is measured in the Cherenkov calorimeter. The results of the measurements carried out in 17400 h of detector operation are compared with those of the simulation based on the CORSIKA package.

  12. Accuracy, reproducibility, and uncertainty analysis of thyroid-probe-based activity measurements for determination of dose calibrator settings.

    PubMed

    Esquinas, Pedro L; Tanguay, Jesse; Gonzalez, Marjorie; Vuckovic, Milan; Rodríguez-Rodríguez, Cristina; Häfeli, Urs O; Celler, Anna

    2016-12-01

    In the nuclear medicine department, the activity of radiopharmaceuticals is measured using dose calibrators (DCs) prior to patient injection. The DC consists of an ionization chamber that measures current generated by ionizing radiation (emitted from the radiotracer). In order to obtain an activity reading, the current is converted into units of activity by applying an appropriate calibration factor (also referred to as DC dial setting). Accurate determination of DC dial settings is crucial to ensure that patients receive the appropriate dose in diagnostic scans or radionuclide therapies. The goals of this study were (1) to describe a practical method to experimentally determine dose calibrator settings using a thyroid-probe (TP) and (2) to investigate the accuracy, reproducibility, and uncertainties of the method. As an illustration, the TP method was applied to determine 188 Re dial settings for two dose calibrator models: Atomlab 100plus and Capintec CRC-55tR. Using the TP to determine dose calibrator settings involved three measurements. First, the energy-dependent efficiency of the TP was determined from energy spectra measurements of two calibration sources ( 152 Eu and 22 Na). Second, the gamma emissions from the investigated isotope ( 188 Re) were measured using the TP and its activity was determined using γ-ray spectroscopy methods. Ambient background, scatter, and source-geometry corrections were applied during the efficiency and activity determination steps. Third, the TP-based 188 Re activity was used to determine the dose calibrator settings following the calibration curve method [B. E. Zimmerman et al., J. Nucl. Med. 40, 1508-1516 (1999)]. The interobserver reproducibility of TP measurements was determined by the coefficient of variation (COV) and uncertainties associated to each step of the measuring process were estimated. The accuracy of activity measurements using the proposed method was evaluated by comparing the TP activity estimates of 99m Tc

  13. Youth Physical Activity Resources Use and Activity Measured by Accelerometry

    PubMed Central

    Maslow, Andréa L.; Colabianchi, Natalie

    2014-01-01

    Objectives To examine whether utilization of physical activity resources (eg, parks) was associated with daily physical activity measured by accelerometry. Methods 111 adolescents completed a travel diary with concurrent accelerometry. The main exposure was self-reported utilization of a physical activity resource (none/1+ resources). The main outcomes were total minutes spent in daily 1) moderate-vigorous physical activity and 2) vigorous physical activity. Results Utilizing a physical activity resource was significantly associated with total minutes in moderate-vigorous physical activity. African-Americans and males had significantly greater moderate-vigorous physical activity. Conclusions Results from this study support the development and use of physical activity resources. PMID:21204684

  14. Youth physical activity resource use and activity measured by accelerometry.

    PubMed

    Maslow, Andréa L; Colabianchi, Natalie

    2011-01-01

    To examine whether use of physical activity resources (eg, parks) was associated with daily physical activity measured by accelerometry. One hundred eleven adolescents completed a travel diary with concurrent accelerometry. The main exposure was self-reported use of a physical activity resource (none /1+ resources). The main outcomes were total minutes spent in daily (1) moderate-vigorous physical activity and (2) vigorous physical activity. Using a physical activity resource was significantly associated with total minutes in moderate-vigorous physical activity. African Americans and males had significantly greater moderate-vigorous physical activity. Results from this study support the development and use of physical activity resources.

  15. Energy Expenditure During Extravehicular Activity Through Apollo

    NASA Technical Reports Server (NTRS)

    Paul, Heather L.

    2011-01-01

    Monitoring crew health during manned space missions has always been an important factor to ensure that the astronauts can complete the missions successfully and within safe physiological limits. The necessity of real-time metabolic rate monitoring during extravehicular activities (EVAs) came into question during the Gemini missions, when the energy expenditure required to complete EVA tasks exceeded the life support capabilities for cooling and humidity control and crewmembers (CMs) ended the EVAs fatigued and overworked. This paper discusses the importance of real-time monitoring of metabolic rate during EVA, and provides a historical look at energy expenditure during EVA through the Apollo program.

  16. Rapid kinetic BRET measurements to monitor G protein activation by GPCR and non-GPCR proteins.

    PubMed

    Maziarz, Marcin; Garcia-Marcos, Mikel

    2017-01-01

    Heterotrimeric G proteins are central hubs of signal transduction whose activity is controlled by G protein-coupled receptors (GPCRs) as well as by a complex network of regulatory proteins. Recently, bioluminescence resonance energy transfer (BRET)-based assays have been used to monitor real-time activation of heterotrimeric G proteins in cells. Here we describe the use of a previously established BRET assay to monitor G protein activation upon GPCR stimulation and its adaptation to measure G protein activation by non-GPCR proteins, such as by cytoplasmic guanine nucleotide exchange factors (GEFs) like GIV/Girdin. The BRET assay monitors the release of free Gβγ from Gα-Gβγ heterotrimers as a readout of G protein activation, which is readily observable upon agonist stimulation of GPCRs. To control the signal input for non-GPCR activators, we describe the use of a chemically induced dimerization strategy to promote rapid membrane translocation of proteins containing the Gα-binding and -activating (GBA) motif found in some nonreceptor GEFs. The assay described here allows the kinetic measurement of G protein activation with subsecond temporal resolution and to compare the levels of activation induced by GPCR agonists vs those induced by the membrane recruitment of nonreceptor G protein signaling activators. © 2017 Elsevier Inc. All rights reserved.

  17. Touch-Initiated Reaction of Nitrogen Triiodide as a Template for Activation Energy Classroom Discussions

    ERIC Educational Resources Information Center

    Short, Duncan

    2017-01-01

    Activation energies form an energy barrier to a chemical reaction taking place. Simple collision theory, i.e. that particles need to collide to react, would suggest that activation energy is the energy needed to overcome a coulombic barrier provided by the negatively charged electrons contained within energy shells surrounding an atomic nucleus.…

  18. Energy Activities for Junior High Social Studies.

    ERIC Educational Resources Information Center

    Minnesota State Energy Agency, St. Paul.

    The document contains seven learning activities for junior high students on the energy situation. Objectives are to help students gain understanding and knowledge about the relationships between humans and their social and physical environments; solve problems and clarify issues; examine personal beliefs and values; and recognize the relationships…

  19. Comparison of four Fitbit and Jawbone activity monitors with a research-grade ActiGraph accelerometer for estimating physical activity and energy expenditure.

    PubMed

    Imboden, Mary T; Nelson, Michael B; Kaminsky, Leonard A; Montoye, Alexander Hk

    2017-05-08

    Consumer-based physical activity (PA) monitors have become popular tools to track PA behaviours. Currently, little is known about the validity of the measurements provided by consumer monitors. We aimed to compare measures of steps, energy expenditure (EE) and active minutes of four consumer monitors with one research-grade accelerometer within a semistructured protocol. Thirty men and women (18-80 years old) wore Fitbit One (worn at the waist), Fitbit Zip (waist), Fitbit Flex (wrist), Jawbone UP24 (wrist) and one waist-worn research-grade accelerometer (ActiGraph) while participating in an 80 min protocol. A validated EE prediction equation and active minute cut-points were applied to ActiGraph data. Criterion measures were assessed using direct observation (step count) and portable metabolic analyser (EE, active minutes). A repeated measures analysis of variance (ANOVA) was used to compare differences between consumer monitors, ActiGraph, and criterion measures. Similarly, a repeated measures ANOVA was applied to a subgroup of subjects who didn't cycle. Participants took 3321±571 steps, had 28±6 active min and expended 294±56 kcal based on criterion measures. Comparatively, all monitors underestimated steps and EE by 13%-32% (p<0.01); additionally the Fitbit Flex, UP24, and ActiGraph underestimated active minutes by 35%-65% (p<0.05). Underestimations of PA and EE variables were found to be similar in the subgroup analysis. Consumer monitors had similar accuracy for PA assessment as the ActiGraph, which suggests that consumer monitors may serve to track personal PA behaviours and EE. However, due to discrepancies among monitors, individuals should be cautious when comparing relative and absolute differences in PA values obtained using different monitors. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. Low-Force Muscle Activity Regulates Energy Expenditure after Spinal Cord Injury.

    PubMed

    Woelfel, Jessica R; Kimball, Amy L; Yen, Chu-Ling; Shields, Richard K

    2017-05-01

    Reduced physical activity is a primary risk factor for increased morbidity and mortality. People with spinal cord injury (SCI) have reduced activity for a lifetime, as they cannot volitionally activate affected skeletal muscles. We explored whether low-force and low-frequency stimulation is a viable strategy to enhance systemic energy expenditure in people with SCI. This study aimed to determine the effects of low stimulation frequency (1 and 3 Hz) and stimulation intensity (50 and 100 mA) on energy expenditure in people with SCI. We also examined the relationship between body mass index and visceral adipose tissue on energy expenditure during low-frequency stimulation. Ten individuals with complete SCI underwent oxygen consumption monitoring during electrical activation of the quadriceps and hamstrings at 1 and 3 Hz and at 50 and 100 mA. We calculated the difference in energy expenditure between stimulation and rest and estimated the number of days that would be necessary to burn 1 lb of body fat (3500 kcal) for each stimulation protocol (1 vs 3 Hz). Both training frequencies induced a significant increase in oxygen consumption above a resting baseline level (P < 0.05). Energy expenditure positively correlated with stimulus intensity (muscle recruitment) and negatively correlated with adiposity (reflecting the insulating properties of adipose tissue). We estimated that 1 lb of body fat could be burned more quickly with 1 Hz training (58 d) as compared with 3 Hz training (87 d) if an identical number of pulses were delivered. Low-frequency stimulation increased energy expenditure per pulse and may be a feasible option to subsidize physical activity to improve metabolic status after SCI.

  1. Novel Approaches to Obesity Prevention: Effects of Game Enjoyment and Game Type on Energy Expenditure in Active Video Games

    PubMed Central

    Lyons, Elizabeth J.; Tate, Deborah F.; Komoski, Stephanie E.; Carr, Philip M.; Ward, Dianne S.

    2012-01-01

    Background Some active video games have been found to promote physical activity adherence because of enjoyment. However, many active games are exercise themed, which may interfere with the distracting properties that make game-based exercise more enjoyable than traditional exercise. This study compared exercise-themed and game-themed active games to investigate differences in energy expenditure and enjoyment. Method Young adults (N = 100, 50 female, 55 overweight, aged 18–35 years) played two of four Wii Fit games (one aerobic game and one balance game per person) for 10 min each. Of the two aerobic games, one was exercise themed (jogging) and the other was game themed (hula hooping). Both balance games were game themed. Energy expenditure and enjoyment were measured. Results After adjustment for gender and weight, aerobic games produced 2.70 kcal/kg-1/h-1 (95% confidence interval 2.41, 3.00) greater energy expenditure than balance games (p < .001), but balance games were more enjoyable (p < .001). In aerobic games, jogging produced greater energy expenditure than hula hooping in normal-weight and male participants (p < .001); in overweight and female participants, no differences were found (p > .17). Hula hooping was enjoyed more than jogging (p = .008). Enjoyment predicted energy expenditure in aerobic games (B = 0.767, p = .010). Conclusions Aerobic games produced greater energy expenditure but lower enjoyment than balance games, and a game-themed aerobic game was found more enjoyable than an exercise-themed aerobic game. Integrating more strenuous activity into entertaining games instead of games that simply simulate exercise may be a fruitful avenue for active game development. PMID:22920810

  2. Novel approaches to obesity prevention: effects of game enjoyment and game type on energy expenditure in active video games.

    PubMed

    Lyons, Elizabeth J; Tate, Deborah F; Komoski, Stephanie E; Carr, Philip M; Ward, Dianne S

    2012-07-01

    Some active video games have been found to promote physical activity adherence because of enjoyment. However, many active games are exercise themed, which may interfere with the distracting properties that make game-based exercise more enjoyable than traditional exercise. This study compared exercise-themed and game-themed active games to investigate differences in energy expenditure and enjoyment. Young adults (N = 100, 50 female, 55 overweight, aged 18-35 years) played two of four Wii Fit games (one aerobic game and one balance game per person) for 10 min each. Of the two aerobic games, one was exercise themed (jogging) and the other was game themed (hula hooping). Both balance games were game themed. Energy expenditure and enjoyment were measured. After adjustment for gender and weight, aerobic games produced 2.70 kcal/kg(-1)/h(-1) (95% confidence interval 2.41, 3.00) greater energy expenditure than balance games (p < .001), but balance games were more enjoyable (p < .001). In aerobic games, jogging produced greater energy expenditure than hula hooping in normal-weight and male participants (p < .001); in overweight and female participants, no differences were found (p > .17). Hula hooping was enjoyed more than jogging (p = .008). Enjoyment predicted energy expenditure in aerobic games (B = 0.767, p = .010). Aerobic games produced greater energy expenditure but lower enjoyment than balance games, and a game-themed aerobic game was found more enjoyable than an exercise-themed aerobic game. Integrating more strenuous activity into entertaining games instead of games that simply simulate exercise may be a fruitful avenue for active game development. © 2012 Diabetes Technology Society.

  3. Thermal energy storage material thermophysical property measurement and heat transfer impact

    NASA Technical Reports Server (NTRS)

    Tye, R. P.; Bourne, J. G.; Destarlais, A. O.

    1976-01-01

    The thermophysical properties of salts having potential for thermal energy storage to provide peaking energy in conventional electric utility power plants were investigated. The power plants studied were the pressurized water reactor, boiling water reactor, supercritical steam reactor, and high temperature gas reactor. The salts considered were LiNO3, 63LiOH/37 LiCl eutectic, LiOH, and Na2B4O7. The thermal conductivity, specific heat (including latent heat of fusion), and density of each salt were measured for a temperature range of at least + or - 100 K of the measured melting point. Measurements were made with both reagent and commercial grades of each salt.

  4. Self-powered suspension criterion and energy regeneration implementation scheme of motor-driven active suspension

    NASA Astrophysics Data System (ADS)

    Yan, Shuai; Sun, Weichao

    2017-09-01

    Active suspension systems have advantages on mitigating the effects of vehicle vibration caused by road roughness, which are one of the most important component parts in influencing the performances of vehicles. However, high amount of energy consumption restricts the application of active suspension systems. From the point of energy saving, this paper presents a self-powered criterion of the active suspension system to judge whether a motor-driven suspension can be self-powered or not, and then a motor parameter condition is developed as a reference to design a self-powered suspension. An energy regeneration implementation scheme is subsequently proposed to make the active suspension which has the potential to be self-powered achieve energy-saving target in the real application. In this implementation scheme, operating electric circuits are designed based on different working status of the actuator and power source and it is realizable to accumulate energy from road vibration and supply energy to the actuator by switching corresponding electric circuits. To apply the self-powered suspension criterion and energy regeneration implementation scheme, an active suspension system is designed with a constrained H∞ controller and calculation results indicate that it has the capability to be self-powered. Simulation results show that the performances of the self-powered active suspension are nearly the same as those of the active suspension with an external energy source and can achieve energy regeneration at the same time.

  5. Measurements of fast ion spatial dynamics during magnetic activity in the RFP

    NASA Astrophysics Data System (ADS)

    Goetz, J. A.; Anderson, J. K.; Bonofiglo, P.; Kim, J.; McConnell, R.; Magee, R. M.

    2017-10-01

    Fast ions in the RFP are only weakly affected by a stochastic magnetic field and behave nearly classically in concentration too low to excite Alfvenic activity. At high fast ion concentration sourced by H-NBI in 300kA RFP discharges, a substantial drop in core-localized high pitch fast ions is observed during bursts of coupled EPM and IAE (magnetic island-induced Alfven eigenmode) activity (100-200kHz) through neutral particle analysis. Sourcing instead fast deuterium with NBI, the DD fusion products can measure the dynamics of the fast ion density profile. Both a collimated neutron detector and a new 3MeV fusion proton detector loaned by TriAlpha Energy measure the fast ion density profile with 5cm spatial resolution and 100 μs temporal resolution. In D-NBI, the bursting EPM is excited at slightly lower frequency and the IAE activity is nearly absent, likely due to an isotope effect and loss of wave-particle interaction. In these cases, neutral particle analysis shows little change in the core-localized high pitch fast ion content, and the fusion product profile indicates little change in the fast ion density profile, leaving unexplained the mechanism removing EPM drive. We measure a substantial redistribution of the fast ion profile due to strong lower-frequency ( 30kHz) MHD activity that accompanies the current profile relaxation in the RFP. Profile flattening is strongest in low bulk density discharges, which often occur with a total increase in global neutron flux from acceleration of the beam ions. Work supported by US DoE.

  6. Energy management and control of active distribution systems

    NASA Astrophysics Data System (ADS)

    Shariatzadeh, Farshid

    Advancements in the communication, control, computation and information technologies have driven the transition to the next generation active power distribution systems. Novel control techniques and management strategies are required to achieve the efficient, economic and reliable grid. The focus of this work is energy management and control of active distribution systems (ADS) with integrated renewable energy sources (RESs) and demand response (DR). Here, ADS mean automated distribution system with remotely operated controllers and distributed energy resources (DERs). DER as active part of the next generation future distribution system includes: distributed generations (DGs), RESs, energy storage system (ESS), plug-in hybrid electric vehicles (PHEV) and DR. Integration of DR and RESs into ADS is critical to realize the vision of sustainability. The objective of this dissertation is the development of management architecture to control and operate ADS in the presence of DR and RES. One of the most challenging issues for operating ADS is the inherent uncertainty of DR and RES as well as conflicting objective of DER and electric utilities. ADS can consist of different layers such as system layer and building layer and coordination between these layers is essential. In order to address these challenges, multi-layer energy management and control architecture is proposed with robust algorithms in this work. First layer of proposed multi-layer architecture have been implemented at the system layer. Developed AC optimal power flow (AC-OPF) generates fair price for all DR and non-DR loads which is used as a control signal for second layer. Second layer controls DR load at buildings using a developed look-ahead robust controller. Load aggregator collects information from all buildings and send aggregated load to the system optimizer. Due to the different time scale at these two management layers, time coordination scheme is developed. Robust and deterministic controllers

  7. Determination of the Arrhenius Activation Energy Using a Temperature-Programmed Flow Reactor.

    ERIC Educational Resources Information Center

    Chan, Kit-ha C.; Tse, R. S.

    1984-01-01

    Describes a novel method for the determination of the Arrhenius activation energy, without prejudging the validity of the Arrhenius equation or the concept of activation energy. The method involves use of a temperature-programed flow reactor connected to a concentration detector. (JN)

  8. Precise measurements of energy loss straggling for swift heavy ions in polymers

    NASA Astrophysics Data System (ADS)

    Rani, Bindu; Neetu; Sharma, Kalpana; Diwan, P. K.; Kumar, Shyam

    2016-11-01

    The energy loss straggling measurements for heavy ions with Z = 3-22 (∼0.2-2.5 MeV/u) in PEN (C7H5O2) and PET (C10H8O4) polymers have been carried out utilizing the swift heavy ion beam facility from 15UD Pelletron accelerator at Inter University Accelerator Centre (IUAC), New Delhi, India. The recorded spectra are analyzed in such a way that the Straggling associated with energy loss process could be measured in a systematic manner at any selected value of energy, in terms of per unit thickness of the absorber, at any desired energy intervals. The measured values have been compared with the calculated values obtained from the most commonly used Bethe-Livingston formulations applicable for collisional straggling. The results are tried to be understood in terms of the effective charge on the impinging ion within the absorber. Some interesting trends are observed.

  9. Energy and power limits for microbial activity

    NASA Astrophysics Data System (ADS)

    LaRowe, D.; Amend, J.

    2014-12-01

    The goal of this presentation is to describe a quantitative framework for determining how energy limits microbial activity, biomass and, ultimately, biogeochemical processes. Although this model can be applied to any environment, its utility is demonstrated in marine sediments, which are an attractive test habitat because they encompass a broad spectrum of energy levels, varying amounts of biomass and are ubiquitous. The potential number of active microbial cells in Arkonas Basin (Baltic Sea) sediments are estimated as a function of depth by quantifying the amount of energy that is available to them and the rate at which it is supplied: power. The amount of power supplied per cubic centimeter of sediment is determined by calculating the Gibbs energy of fermentation and sulfate reduction in combination with the rate of particulate organic carbon, POC, degradation. The Reactive Continuum Model (Boudreau and Ruddick, 1991), RCM, is used to determine the rate at which POC is made available for microbial consumption. The RCM represents POC as containing a range of different types of organic compounds whose ability to be consumed by microorganisms varies as a function of the age of the sediment and on the distribution of compound types that were initially deposited. The sediment age model and RCM parameters determined by (Mogollon et al., 2012) are used. The power available for fermentation and sulfate reduction coupled to H2 and acetate oxidation varies from 10-8 W cm-3 at the sediment water interface to between 10-11 - 10-12 W cm-3 at 3.5 meters below the seafloor, mbsf. Using values of maintenance powers for each of these catabolic activities taken from the literature, the total number of active cells in these sediments similarly decreases from just less than 108 cell cm-3 at the SWI to 4.6 x 104 cells cm-3 at 3.5 mbsf. The number of moles of POC decreases from 2.6 x 10-5 to 9.5 x 10-6, also becoming more recalcitrant with depth. Boudreau, B. P. and Ruddick, B. R

  10. Energy and Safety: Science Activities for Elementary Students, Level III (Grades (5-6).

    ERIC Educational Resources Information Center

    Westcott, Dale; And Others

    Thirteen activities are presented that focus on a common phenomenon of a child's world: energy. These activities relate energy, how it occurs, how it is used, and how to use it safely. Each activity includes the purpose, introduction, background, procedure, materials, estimated time for the activity, typical results, safety notes, and more ideas.…

  11. The activation energy for nanocrystalline diamond films deposited from an Ar/H2/CH4 hot-filament reactor.

    PubMed

    Barbosa, D C; Melo, L L; Trava-Airoldi, V J; Corat, E J

    2009-06-01

    In this work we have investigated the effect of substrate temperature on the growth rate and properties of nanocrystalline diamond thin films deposited by hot filament chemical vapor deposition (HFCVD). Mixtures of 0.5 vol% CH4 and 25 vol% H2 balanced with Ar at a pressure of 50 Torr and typical deposition time of 12 h. We present the measurement of the activation energy by accurately controlling the substrate temperature independently of other CVD parameters. Growth rates have been measured in the temperature range from 550 to 800 degrees C. Characterization techniques have involved Raman spectroscopy, high resolution X-ray difractometry and scanning electron microscopy. We also present a comparison with most activation energy for micro and nanocrystalline diamond determinations in the literature and propose that there is a common trend in most observations. The result obtained can be an evidence that the growth mechanism of NCD in HFCVD reactors is very similar to MCD growth.

  12. Does increased exercise or physical activity alter ad-libitum daily energy intake or macronutrient composition in healthy adults? A systematic review.

    PubMed

    Donnelly, Joseph E; Herrmann, Stephen D; Lambourne, Kate; Szabo, Amanda N; Honas, Jeffery J; Washburn, Richard A

    2014-01-01

    The magnitude of the negative energy balance induced by exercise may be reduced due to compensatory increases in energy intake. TO ADDRESS THE QUESTION: Does increased exercise or physical activity alter ad-libitum daily energy intake or macronutrient composition in healthy adults? PubMed and Embase were searched (January 1990-January 2013) for studies that presented data on energy and/or macronutrient intake by level of exercise, physical activity or change in response to exercise. Ninety-nine articles (103 studies) were included. Primary source articles published in English in peer-reviewed journals. Articles that presented data on energy and/or macronutrient intake by level of exercise or physical activity or changes in energy or macronutrient intake in response to acute exercise or exercise training in healthy (non-athlete) adults (mean age 18-64 years). Articles were grouped by study design: cross-sectional, acute/short term, non-randomized, and randomized trials. Considerable heterogeneity existed within study groups for several important study parameters, therefore a meta-analysis was considered inappropriate. Results were synthesized and presented by study design. No effect of physical activity, exercise or exercise training on energy intake was shown in 59% of cross-sectional studies (n = 17), 69% of acute (n = 40), 50% of short-term (n = 10), 92% of non-randomized (n = 12) and 75% of randomized trials (n = 24). Ninety-four percent of acute, 57% of short-term, 100% of non-randomized and 74% of randomized trials found no effect of exercise on macronutrient intake. Forty-six percent of cross-sectional trials found lower fat intake with increased physical activity. The literature is limited by the lack of adequately powered trials of sufficient duration, which have prescribed and measured exercise energy expenditure, or employed adequate assessment methods for energy and macronutrient intake. We found no consistent evidence that increased physical activity or

  13. Empowering Sedentary Adults to Reduce Sedentary Behavior and Increase Physical Activity Levels and Energy Expenditure: A Pilot Study

    PubMed Central

    Barwais, Faisal A.; Cuddihy, Thomas F.

    2015-01-01

    Objective: The purpose of this study was to assess the effectiveness of a 4-week intervention in which an online personal activity monitor (Gruve-Technologies™) was used to reduce sedentary behavior among sedentary adults. Method: Eighteen, sedentary adult volunteers (12 men, six women, mean age 29 ± 4.0 years) were recruited to participate in the study. Time spent in sedentary activities and light-, moderate-, and vigorous-intensity physical activity and energy expenditure were assessed during waking hours using the monitor and the 7-day SLIPA Log at both baseline and post-intervention. Results: A significant decrease of 33% (3.1 h/day; p < 0.001) was found between the time spent in sedentary activities measured at baseline (9.4 ± 1.1 h/day) and at the end of the 4-week intervention (6.3 ± 0.8 h/day). Consequent to the changes in sedentary time, significant increases were found in the amount of time spent in light- (45% (2.6 h/day), p < 0.001), moderate- (33% (1 h/day) p < 0.001), vigorous-intensity physical activity (39% (0.16 h/day), p < 0.001), and energy expenditure (47% (216.7 kcal/day), p < 0.001). Conclusion: This monitor contributes to a meaningful reduction in time spent in sedentary activities and has a large effect on energy expenditure and physical activity patterns. PMID:25568971

  14. Directed energy deflection laboratory measurements of common space based targets

    NASA Astrophysics Data System (ADS)

    Brashears, Travis; Lubin, Philip; Hughes, Gary B.; Meinhold, Peter; Batliner, Payton; Motta, Caio; Madajian, Jonathan; Mercer, Whitaker; Knowles, Patrick

    2016-09-01

    We report on laboratory studies of the effectiveness of directed energy planetary defense as a part of the DE-STAR (Directed Energy System for Targeting of Asteroids and exploRation) program. DE-STAR and DE-STARLITE are directed energy "stand-off" and "stand-on" programs, respectively. These systems consist of a modular array of kilowatt-class lasers powered by photovoltaics, and are capable of heating a spot on the surface of an asteroid to the point of vaporization. Mass ejection, as a plume of evaporated material, creates a reactionary thrust capable of diverting the asteroid's orbit. In a series of papers, we have developed a theoretical basis and described numerical simulations for determining the thrust produced by material evaporating from the surface of an asteroid. In the DESTAR concept, the asteroid itself is used as the deflection "propellant". This study presents results of experiments designed to measure the thrust created by evaporation from a laser directed energy spot. We constructed a vacuum chamber to simulate space conditions, and installed a torsion balance that holds a common space target sample. The sample is illuminated with a fiber array laser with flux levels up to 60 MW/m2 , which allows us to simulate a mission level flux but on a small scale. We use a separate laser as well as a position sensitive centroid detector to readout the angular motion of the torsion balance and can thus determine the thrust. We compare the measured thrust to the models. Our theoretical models indicate a coupling coefficient well in excess of 100 μN/Woptical, though we assume a more conservative value of 80 μN/Woptical and then degrade this with an optical "encircled energy" efficiency of 0.75 to 60 μN/Woptical in our deflection modeling. Our measurements discussed here yield about 45 μN/Wabsorbed as a reasonable lower limit to the thrust per optical watt absorbed. Results vary depending on the material tested and are limited to measurements of 1 axis, so

  15. The Improved Physical Activity Index for Measuring Physical Activity in EPIC Germany

    PubMed Central

    Wientzek, Angelika; Vigl, Matthäus; Steindorf, Karen; Brühmann, Boris; Bergmann, Manuela M.; Harttig, Ulrich; Katzke, Verena; Kaaks, Rudolf; Boeing, Heiner

    2014-01-01

    In the European Investigation into Cancer and Nutrition study (EPIC), physical activity (PA) has been indexed as a cross-tabulation between PA at work and recreational activity. As the proportion of non-working participants increases, other categorization strategies are needed. Therefore, our aim was to develop a valid PA index for this population, which will also be able to express PA continuously. In the German EPIC centers Potsdam and Heidelberg, a clustered sample of 3,766 participants was re-invited to the study center. 1,615 participants agreed to participate and 1,344 participants were finally included in this study. PA was measured by questionnaires on defined activities and a 7-day combined heart rate and acceleration sensor. In a training sample of 433 participants, the Improved Physical Activity Index (IPAI) was developed. Its performance was evaluated in a validation sample of 911 participants and compared with the Cambridge Index and the Total PA Index. The IPAI consists of items covering five areas including PA at work, sport, cycling, television viewing, and computer use. The correlations of the IPAI with accelerometer counts in the training and validation sample ranged r = 0.40–0.43 and with physical activity energy expenditure (PAEE) r = 0.33–0.40 and were higher than for the Cambridge Index and the Total PA Index previously applied in EPIC. In non-working participants the IPAI showed higher correlations than the Cambridge Index and the Total PA Index, with r = 0.34 for accelerometer counts and r = 0.29 for PAEE. In conclusion, we developed a valid physical activity index which is able to express PA continuously as well as to categorize participants according to their PA level. In populations with increasing rates of non-working people the performance of the IPAI is better than the established indices used in EPIC. PMID:24642812

  16. Measured Early Lateral Energy Fractions in Concert Halls and Opera Houses

    NASA Astrophysics Data System (ADS)

    BARRON, M.

    2000-04-01

    In the 30 years since early lateral reflections were first suggested as important for concert halls, spatial impression and source broadening have become almost universally accepted as essential characteristics of halls with good acoustics. Two objective measures of source broadening have been proposed. Measured values of the best defined of these measures, the early lateral energy fraction (LF), are considered here. Results from two independent measurement surveys are discussed. Comparisons of LF values by hall show a significant link between hall mean LF and hall width. There is however considerable overlap between measured LF values in different halls so the relevance of describing halls by their mean early lateral energy fraction values is questionable. The behaviour of LF values within auditoria is discussed for different concert hall plan forms and within opera houses. A measure of source broadening including sound level is proposed and results considered in the context of auditorium design.

  17. Intercomparison measurements with energy deposition spectrometer Liulin and TEPC Hawk at HIMAC, and related calculations with PHITS

    NASA Astrophysics Data System (ADS)

    Ploc, Ondrej; Uchihori, Yukio; Kitamura, H.; Kodaira, S.; Dachev, Tsvetan; Spurny, Frantisek; Jadrnickova, Iva; Mrazova, Zlata; Kubancak, Jan

    Liulin type detectors are recently used in a wide range of cosmic radiation measurements, e.g. at alpine observatories, onboard aircrafts and spacecrafts. They provide energy deposition spectra up to 21 MeV, higher energy deposition events are stored in the last (overflow) channel. Their main advantages are portability (about the same size as a pack of cigarettes) and ability to record spectra as a function of time, so they can be used as personal dosimeters. Their well-known limitations are: (i) the fact that they are not tissue equivalent, (ii) they can be used as LET spectrometer only under specific conditions (e.g. broad parallel beam), and (iii) that the energy deposition event from particles of LETH20¿35 keV/µm is stored in the overflow bin only so the spectral information is missing. Tissue equivalent proportional counter (TEPC) Hawk has no of these limitations but on the other hand, it cannot be used as personal dosimeter because of its big size (cylinder of 16 cm diameter and 34 cm long). An important fraction of dose equivalent onboard spacecrafts is caused by heavy ions. This contribution presents results from intercomparison measurements with Liulin and Hawk at Heavy Ion Medical Accelerator in Chiba (HIMAC) and cyclotron beams, and related calculations with PHITS (Particle and Heavy-ion Transport code System). Following particles/ions and energies were used: protons 70 MeV, He 150 MeV, Ne 400 MeV, C 135 MeV, C 290 MeV, and Fe 500 MeV. Calculations of LET spectra by PHITS were performed for both, Liulin and Hawk. In case of Liulin, the dose equivalent was calculated using simulations in which several tissue equivalent materials were used as active volume instead of the silicon diode. Dose equivalents calculated in such way was compared with that measured with Hawk. LET spectra measured with Liulin and Hawk were compared for each ion at several points behind binary filters along the Brag curve. Good agreement was observed for some configurations; for

  18. Associations between self-reported and objectively measured physical activity, sedentary behavior and overweight/obesity in NHANES 2003-2006.

    PubMed

    Wanner, M; Richard, A; Martin, B; Faeh, D; Rohrmann, S

    2017-01-01

    To investigate associations between self-reported and objectively measured physical activity, sedentary behavior and overweight/obesity based on percent body fat measured with Dual Energy X-Ray Absorptiometry (DXA), waist circumference (WC), waist-to-height ratio and body mass index, focusing on different intensities and domains of physical activity. Data from NHANES 2003-2006 were analyzed using linear and ordered logistic regression analyses. A total of 4794 individuals aged 18-69 years with valid physical activity and DXA data were included. Objectively measured physical activity and sedentary behavior were assessed using accelerometers, self-reported physical activity using the NHANES physical activity questionnaire. Weight, height, WC and DXA measures were assessed in the mobile examination centers. We observed statistically significant associations between objectively measured moderate and vigorous physical activity and all definitions of overweight/obesity. For total physical activity, the odds of being in the higher percent body fat category were 0.56 (95% confidence interval (CI) 0.41, 0.77) for the medium and 0.30 (95% CI 0.22, 0.40) for the highest physical activity tertile compared with the lowest. For light activities, lifestyle activities and sedentary behavior, associations were only observed in the linear models with percent total body fat but not in the ordered logistic regression models. Regarding self-reported physical activity, consistent significant associations with overweight/obesity were only observed for vigorous and for transport activity. Regarding moderate and vigorous physical activity, more active individuals were less affected by overweight/obesity than less active individuals, emphasizing the public health effect of physical activity in the prevention of overweight/obesity. The fact that associations were more consistent for objectively measured than for self-reported physical activity may be due to bias related to self

  19. Flowable Conducting Particle Networks in Redox-Active Electrolytes for Grid Energy Storage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hatzell, K. B.; Boota, M.; Kumbur, E. C.

    2015-01-01

    This study reports a new hybrid approach toward achieving high volumetric energy and power densities in an electrochemical flow capacitor for grid energy storage. The electrochemical flow capacitor suffers from high self-discharge and low energy density because charge storage is limited to the available surface area (electric double layer charge storage). Here, we examine two carbon materials as conducting particles in a flow battery electrolyte containing the VO2+/VO2+ redox couple. Highly porous activated carbon spheres (CSs) and multi-walled carbon nanotubes (MWCNTs) are investigated as conducting particle networks that facilitate both faradaic and electric double layer charge storage. Charge storage contributionsmore » (electric double layer and faradaic) are distinguished for flow-electrodes composed of MWCNTs and activated CSs. A MWCNT flow-electrode based in a redox-active electrolyte containing the VO2+/VO2+ redox couple demonstrates 18% less self-discharge, 10 X more energy density, and 20 X greater power densities (at 20 mV s-1) than one based on a non-redox active electrolyte. Furthermore, a MWCNT redox-active flow electrode demonstrates 80% capacitance retention, and >95% coulombic efficiency over 100 cycles, indicating the feasibility of utilizing conducting networks with redox chemistries for grid energy storage.« less

  20. Flowable conducting particle networks in redox-active electrolytes for grid energy storage

    DOE PAGES

    Hatzell, K. B.; Boota, M.; Kumbur, E. C.; ...

    2015-01-09

    This paper reports a new hybrid approach toward achieving high volumetric energy and power densities in an electrochemical flow capacitor for grid energy storage. The electrochemical flow capacitor suffers from high self-discharge and low energy density because charge storage is limited to the available surface area (electric double layer charge storage). Here, we examine two carbon materials as conducting particles in a flow battery electrolyte containing the VO 2+/VO 2 + redox couple. Highly porous activated carbon spheres (CSs) and multi-walled carbon nanotubes (MWCNTs) are investigated as conducting particle networks that facilitate both faradaic and electric double layer charge storage.more » Charge storage contributions (electric double layer and faradaic) are distinguished for flow-electrodes composed of MWCNTs and activated CSs. A MWCNT flow-electrode based in a redox-active electrolyte containing the VO 2+/VO 2 + redox couple demonstrates 18% less self-discharge, 10 X more energy density, and 20 X greater power densities (at 20 mV s -1) than one based on a non-redox active electrolyte. Additionally, a MWCNT redox-active flow electrode demonstrates 80% capacitance retention, and >95% coulombic efficiency over 100 cycles, indicating the feasibility of utilizing conducting networks with redox chemistries for grid energy storage.« less

  1. Effect of hyperthyroidism on spontaneous physical activity and energy expenditure in rats.

    PubMed

    Levine, James A; Nygren, Jonas; Short, Kevin R; Nair, K Sreekumaran

    2003-01-01

    Thyroid hormone excess is associated with increased energy expenditure. The contributions of increases in spontaneous physical activity and nonexercise activity thermogenesis (NEAT) to this effect have not been defined. To address the hypothesis that hyperthyroidism is associated with increased spontaneous physical activity and NEAT, we rendered rats hyperthyroid by using continuous infusion of high-dose triiodothyronine for 14 days and measured the effects on physical activity and NEAT. On day 14, in the hyperthyroid group the mean +/- SD triiodothyronine concentration was 755 +/- 137 (range 574-919) ng/dl and in the control group 59 +/- 0.5 (58-59) ng/dl. Over the 14-day treatment period, mean spontaneous physical activity increased in the hyperthyroid rats from 24 +/- 7 to 36 +/- 6 activity units (AU)/min; P < 0.001 but did not increase in the controls (23 +/- 7 vs. 22 +/- 4 AU/min). Also, over the 14-day period, daily NEAT increased in the hyperthyroid rats from 8.1 +/- 2.8 to 19.7 +/- 5.0 kcal/day (P < 0.001) but did not increase in the controls (8.7 +/- 3.5 cf 9.4 +/- 1.7 kcal/day; not significant). In conclusion, hyperthyroidism is associated with increased spontaneous physical activity and NEAT.

  2. Measurement of the low energy spectral contribution in coincidence with valence band (VB) energy levels of Ag(100) using VB-VB coincidence spectroscopy

    NASA Astrophysics Data System (ADS)

    Gladen, R. W.; Joglekar, P. V.; Lim, Z. H.; Shastry, K.; Hulbert, S. L.; Weiss, A. H.

    A set of coincidence measurements were obtained for the study and measurement of the electron contribution arising from the inter-valence band (VB) transitions along with the inelastically scattered VB electron contribution. These Auger-unrelated contributions arise in the Auger spectrum (Ag 4p NVV) obtained using Auger Photoelectron Coincidence Spectroscopy (APECS). The measured Auger-unrelated contribution can be eliminated from Auger spectrum to obtain the spectrum related to Auger. In our VB-VB coincidence measurement, a photon beam of energy 180eV was used to probe the Ag(100) sample. The coincidence spectrum was obtained using two Cylindrical Mirror Analyzers (CMA's). The scan CMA measured the low energy electron contribution in the energy range 0-70eV in coincidence with VB electrons measured by the fixed CMA. In this talk, we present the data obtained for VB-VB coincidence at the valence band energy of 171eV along with the coincidence measurements in the energy range of 4p core and valence band. NSF DMR 0907679, NSF Award Number: 1213727. Use of the National Synchrotron Light Source, Brookhaven National Laboratory, was supported by the U.S. DOE, Office of Science, Office of Basic Energy Sciences, under Contract No. DEAC02-98CH10886.

  3. Measurement of the low energy spectral contribution in coincidence with valence band (VB) energy levels of Ag(100) using VB-VB coincidence spectroscopy

    NASA Astrophysics Data System (ADS)

    Joglekar, P. V.; Gladen, R.; Lim, Z. H.; Shastry, K.; Hulbert, S. L.; Weiss, A. H.

    2015-03-01

    A set of coincidence measurements were obtained for the study and measurement of the electron contribution arising from the inter-valence band (VB) transitions along with the inelastically scattered VB electron contribution. These Auger-unrelated contributions arise in the Auger spectrum (Ag 4p NVV) obtained using Auger Photoelectron Coincidence Spectroscopy (APECS). The measured Auger-unrelated contribution can be eliminated from Auger spectrum to obtain the spectrum related to Auger. In our VB-VB coincidence measurement, a photon beam of energy 180eV was used to probe the Ag(100) sample. The coincidence spectrum was obtained using two Cylindrical Mirror Analyzers (CMA's). The scan CMA measured the low energy electron contribution in the energy range 0-70eV in coincidence with VB electrons measured by the fixed CMA. In this talk, we present the data obtained for VB-VB coincidence at the valence band energy of 171eV along with the coincidence measurements in the energy range of 4p core and valence band. NSF DMR 0907679, NSF Award Number: 1213727. Use of the National Synchrotron Light Source, Brookhaven National Laboratory, was supported by the U.S. DOE, Office of Science, Office of Basic Energy Sciences, under Contract No. DE-AC02-98CH10886.

  4. Reducing and measuring fluctuations in the MST RFP: Enhancement of energy confinement and measurement of the MHD dynamo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Den Hartog, D.J.; Almagri, A.F.; Cekic, M.

    1996-09-01

    A three- to five-fold enhancement of the energy confinement time in a reversed-field pinch (RFP) has been achieved in the Madison Symmetric Torus (MST) by reducing the amplitude of tearing mode fluctuations responsible for anomalous transport in the core of the RFP. By applying a transient poloidal inductive electric field to flatten the current density profile, the fluctuation amplitude {tilde b}/B decreases from 1.5% to 0.8%, the electron temperature T{sub e0} increases from 250 eV to 370 eV, the ohmic input power decreases from 4.5 MW to approximately 1.5 MW, the poloidal beta {beta}{sub 0} increases from 6% to 9%,more » and the energy confinement time {tau}{sub E} increases from 1 ms to {approximately}5 ms in I{sub {phi}} = 340 kA plasmas with density {tilde n} = 1 {times} 10{sup 19} m{sup -3}. Current profile control methods are being developed for the RFP in a program to eliminate transport associated with these current-gradient-driven fluctuations. In addition to controlling the amplitude of the tearing modes, we are vigorously pursuing an understanding of the physics of these fluctuations. In particular, plasma flow, both equilibrium and fluctuating, plays a critical role in a diversity of physical phenomena in MST. The key results: 1) Edge probe measurements show that the MHD dynamo is active in low collisionality plasmas, while at high collisionality a new mechanism, the `electron diamagnetic dynamo,` is observed. 2) Core spectroscopic measurements show that the toroidal velocity fluctuations of the plasma are coherent with the large-scale magnetic tearing modes; the scalar product of these two fluctuating quantities is similar to that expected for the MHD dynamo electromotive force. 3) Toroidal plasma flow in MST exhibits large radial shear and can be actively controlled, including unlocking locked discharges, by modifying E{sub r} with a robust biased probe. 24 refs.« less

  5. Energy-related parameters and their association with age, gender, and morphometric measurements in healthy donkeys.

    PubMed

    Mendoza, F J; Estepa, J C; Gonzalez-De Cara, C A; Aguilera-Aguilera, R; Toribio, R E; Perez-Ecija, A

    2015-05-01

    Donkeys are commonly afflicted by endocrine and metabolic disturbances but few studies have investigated endocrine variables involved in energy regulation and their association with morphometric indices, age or gender in this species. Hemostatic and clinical differences have been demonstrated between horses and donkeys, so to consider both species as metabolically and endocrinologically similar could lead to misdiagnosis. In this study, plasma concentrations of glucose, triglycerides and endocrine factors involved in energy homeostasis (insulin, glucagon, leptin, adiponectin, ghrelin and insulin-like growth factor [IGF]-1) were measured and their association with morphometric variables (body condition score, neck scoring and body mass index), gender and age was determined in 62 healthy donkeys. In addition, a neck scoring system specific for donkeys was developed. Insulin, glucagon, leptin and IGF-1 concentrations were found to be similar between donkeys and other species, but adiponectin and active ghrelin were lower in donkeys than horses. Donkeys with larger neck scores and body mass indices had higher triglyceride, leptin and IGF-1 concentrations. A sexual dimorphism was observed on all morphometric measurements and plasma glucose concentrations independent of adiposity. Younger animals had lower morphometric measurements and triglyceride and leptin concentrations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Measuring the Built Environment for Physical Activity

    PubMed Central

    Brownson, Ross C.; Hoehner, Christine M.; Day, Kristen; Forsyth, Ann; Sallis, James F.

    2009-01-01

    Physical inactivity is one of the most important public health issues in the U.S. and internationally. Increasingly, links are being identified between various elements of the physical—or built—environment and physical activity. To understand the impact of the built environment on physical activity, the development of high-quality measures is essential. Three categories of built environment data are being used: (1) perceived measures obtained by telephone interview or self-administered questionnaires; (2) observational measures obtained using systematic observational methods (audits); and (3) archival data sets that are often layered and analyzed with GIS. This review provides a critical assessment of these three types of built-environment measures relevant to the study of physical activity. Among perceived measures, 19 questionnaires were reviewed, ranging in length from 7 to 68 questions. Twenty audit tools were reviewed that cover community environments (i.e., neighborhoods, cities), parks, and trails. For GIS-derived measures, more than 50 studies were reviewed. A large degree of variability was found in the operationalization of common GIS measures, which include population density, land-use mix, access to recreational facilities, and street pattern. This first comprehensive examination of built-environment measures demonstrates considerable progress over the past decade, showing diverse environmental variables available that use multiple modes of assessment. Most can be considered first-generation measures, so further development is needed. In particular, further research is needed to improve the technical quality of measures, understand the relevance to various population groups, and understand the utility of measures for science and public health. PMID:19285216

  7. Energy Expenditure During Extravehicular Activity Through Apollo

    NASA Technical Reports Server (NTRS)

    Paul, Heather L.

    2012-01-01

    Monitoring crew health during manned space missions has always been an important factor to ensure that the astronauts can complete the missions successfully and within safe physiological limits. The necessity of real-time metabolic rate monitoring during extravehicular activities (EVAs) came into question during the Gemini missions, when the energy expenditure required to complete EVA tasks exceeded the life support capabilities for cooling and humidity control and, as a result, crew members ended the EVAs fatigued and overworked. This paper discusses the importance of real-time monitoring of metabolic rate during EVAs, and provides a historical look at energy expenditure during EVAs through the Apollo Program.

  8. Thermogravimetric study and kinetic analysis of fungal pretreated corn stover using the distributed activation energy model.

    PubMed

    Ma, Fuying; Zeng, Yelin; Wang, Jinjin; Yang, Yang; Yang, Xuewei; Zhang, Xiaoyu

    2013-01-01

    Non-isothermal thermogravimetry/derivative thermogravimetry (TG/DTG) measurements are used to determine pyrolytic characteristics and kinetics of lignocellulose. TG/DTG experiments at different heating rates with corn stover pretreated with monocultures of Irpex lacteus CD2 and Auricularia polytricha AP and their cocultures were conducted. Heating rates had little effect on the pyrolysis process, but the peak of weight loss rate in the DTG curves shifted towards higher temperature with heating rate. The maximum weight loss of biopretreated samples was 1.25-fold higher than that of the control at the three heating rates, and the maximum weight loss rate of the co-culture pretreated samples was intermediate between that of the two mono-cultures. The activation energies of the co-culture pretreated samples were 16-72 kJ mol(-1) lower than that of the mono-culture at the conversion rate range from 10% to 60%. This suggests that co-culture pretreatment can decrease activation energy and accelerate pyrolysis reaction thus reducing energy consumption. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Measurement of the ν _{μ } energy spectrum with IceCube-79

    NASA Astrophysics Data System (ADS)

    Aartsen, M. G.; Ackermann, M.; Adams, J.; Aguilar, J. A.; Ahlers, M.; Ahrens, M.; Al Samarai, I.; Altmann, D.; Andeen, K.; Anderson, T.; Ansseau, I.; Anton, G.; Archinger, M.; Argüelles, C.; Auffenberg, J.; Axani, S.; Bagherpour, H.; Bai, X.; Barwick, S. W.; Baum, V.; Bay, R.; Beatty, J. J.; Becker Tjus, J.; Becker, K.-H.; BenZvi, S.; Berley, D.; Bernardini, E.; Besson, D. Z.; Binder, G.; Bindig, D.; Blaufuss, E.; Blot, S.; Bohm, C.; Börner, M.; Bos, F.; Bose, D.; Böser, S.; Botner, O.; Bradascio, F.; Braun, J.; Brayeur, L.; Bretz, H.-P.; Bron, S.; Burgman, A.; Carver, T.; Casier, M.; Cheung, E.; Chirkin, D.; Christov, A.; Clark, K.; Classen, L.; Coenders, S.; Collin, G. H.; Conrad, J. M.; Cowen, D. F.; Cross, R.; Day, M.; de André, J. P. A. M.; De Clercq, C.; del Pino Rosendo, E.; Dembinski, H.; De Ridder, S.; Desiati, P.; de Vries, K. D.; de Wasseige, G.; de With, M.; DeYoung, T.; Díaz-Vélez, J. C.; di Lorenzo, V.; Dujmovic, H.; Dumm, J. P.; Dunkman, M.; Eberhardt, B.; Ehrhardt, T.; Eichmann, B.; Eller, P.; Euler, S.; Evenson, P. A.; Fahey, S.; Fazely, A. R.; Feintzeig, J.; Felde, J.; Filimonov, K.; Finley, C.; Flis, S.; Fösig, C.-C.; Franckowiak, A.; Friedman, E.; Fuchs, T.; Gaisser, T. K.; Gallagher, J.; Gerhardt, L.; Ghorbani, K.; Giang, W.; Gladstone, L.; Glauch, T.; Glüsenkamp, T.; Goldschmidt, A.; Gonzalez, J. G.; Grant, D.; Griffith, Z.; Haack, C.; Hallgren, A.; Halzen, F.; Hansen, E.; Hansmann, T.; Hanson, K.; Hebecker, D.; Heereman, D.; Helbing, K.; Hellauer, R.; Hickford, S.; Hignight, J.; Hill, G. C.; Hoffman, K. D.; Hoffmann, R.; Hoshina, K.; Huang, F.; Huber, M.; Hultqvist, K.; In, S.; Ishihara, A.; Jacobi, E.; Japaridze, G. S.; Jeong, M.; Jero, K.; Jones, B. J. P.; Kang, W.; Kappes, A.; Karg, T.; Karle, A.; Katz, U.; Kauer, M.; Keivani, A.; Kelley, J. L.; Kheirandish, A.; Kim, J.; Kim, M.; Kintscher, T.; Kiryluk, J.; Kittler, T.; Klein, S. R.; Kohnen, G.; Koirala, R.; Kolanoski, H.; Konietz, R.; Köpke, L.; Kopper, C.; Kopper, S.; Koskinen, D. J.; Kowalski, M.; Krings, K.; Kroll, M.; Krückl, G.; Krüger, C.; Kunnen, J.; Kunwar, S.; Kurahashi, N.; Kuwabara, T.; Kyriacou, A.; Labare, M.; Lanfranchi, J. L.; Larson, M. J.; Lauber, F.; Lennarz, D.; Lesiak-Bzdak, M.; Leuermann, M.; Lu, L.; Lünemann, J.; Madsen, J.; Maggi, G.; Mahn, K. B. M.; Mancina, S.; Maruyama, R.; Mase, K.; Maunu, R.; McNally, F.; Meagher, K.; Medici, M.; Meier, M.; Menne, T.; Merino, G.; Meures, T.; Miarecki, S.; Micallef, J.; Momenté, G.; Montaruli, T.; Moulai, M.; Nahnhauer, R.; Naumann, U.; Neer, G.; Niederhausen, H.; Nowicki, S. C.; Nygren, D. R.; Obertacke Pollmann, A.; Olivas, A.; O'Murchadha, A.; Palczewski, T.; Pandya, H.; Pankova, D. V.; Peiffer, P.; Penek, Ö.; Pepper, J. A.; Pérez de los Heros, C.; Pieloth, D.; Pinat, E.; Price, P. B.; Przybylski, G. T.; Quinnan, M.; Raab, C.; Rädel, L.; Rameez, M.; Rawlins, K.; Reimann, R.; Relethford, B.; Relich, M.; Resconi, E.; Rhode, W.; Richman, M.; Riedel, B.; Robertson, S.; Rongen, M.; Rott, C.; Ruhe, T.; Ryckbosch, D.; Rysewyk, D.; Sabbatini, L.; Sanchez Herrera, S. E.; Sandrock, A.; Sandroos, J.; Sarkar, S.; Satalecka, K.; Schlunder, P.; Schmidt, T.; Schoenen, S.; Schöneberg, S.; Schumacher, L.; Seckel, D.; Seunarine, S.; Soldin, D.; Song, M.; Spiczak, G. M.; Spiering, C.; Stachurska, J.; Stanev, T.; Stasik, A.; Stettner, J.; Steuer, A.; Stezelberger, T.; Stokstad, R. G.; Stößl, A.; Ström, R.; Strotjohann, N. L.; Sullivan, G. W.; Sutherland, M.; Taavola, H.; Taboada, I.; Tatar, J.; Tenholt, F.; Ter-Antonyan, S.; Terliuk, A.; Tešić, G.; Tilav, S.; Toale, P. A.; Tobin, M. N.; Toscano, S.; Tosi, D.; Tselengidou, M.; Tung, C. F.; Turcati, A.; Unger, E.; Usner, M.; Vandenbroucke, J.; van Eijndhoven, N.; Vanheule, S.; van Rossem, M.; van Santen, J.; Vehring, M.; Voge, M.; Vogel, E.; Vraeghe, M.; Walck, C.; Wallace, A.; Wallraff, M.; Wandkowsky, N.; Waza, A.; Weaver, Ch.; Weiss, M. J.; Wendt, C.; Westerhoff, S.; Whelan, B. J.; Wickmann, S.; Wiebe, K.; Wiebusch, C. H.; Wille, L.; Williams, D. R.; Wills, L.; Wolf, M.; Wood, T. R.; Woolsey, E.; Woschnagg, K.; Xu, D. L.; Xu, X. W.; Xu, Y.; Yanez, J. P.; Yodh, G.; Yoshida, S.; Zoll, M.

    2017-10-01

    IceCube is a neutrino observatory deployed in the glacial ice at the geographic South Pole. The ν _μ energy unfolding described in this paper is based on data taken with IceCube in its 79-string configuration. A sample of muon neutrino charged-current interactions with a purity of 99.5% was selected by means of a multivariate classification process based on machine learning. The subsequent unfolding was performed using the software Truee. The resulting spectrum covers an E_ν -range of more than four orders of magnitude from 125 GeV to 3.2 PeV. Compared to the Honda atmospheric neutrino flux model, the energy spectrum shows an excess of more than 1.9 σ in four adjacent bins for neutrino energies E_ν ≥ 177.8 {TeV}. The obtained spectrum is fully compatible with previous measurements of the atmospheric neutrino flux and recent IceCube measurements of a flux of high-energy astrophysical neutrinos.

  10. Correlation of the CME Productivity of Solar Active Regions with Measures of their Global Nonpotentiality from Vector Magnetograms: Baseline Results

    NASA Technical Reports Server (NTRS)

    Falconer, David A.; Moore, Ron L.; Gary, G. Allen; Six, N. Frank (Technical Monitor)

    2001-01-01

    From conventional magnetograms and chromospheric and coronal images, it is known qualitatively that the fastest coronal mass ejections (CMEs) are magnetic explosions from sunspot active regions in which the magnetic field is globally strongly sheared and twisted from its minimum-energy potential configuration. In this paper, we present measurements from active-region vector magnetograms that begin to quantify the dependence of the CME productivity of an active region on the global nonpotentiality of its magnetic field. From each of 17 magnetograms of 12 bipolar active regions, we obtain a measure of the size of the active region (the magnetic flux content, phi) and three different measures of the global nonpotentiality (L(sub SS), the length of strong-shear, strong-field main neutral line; I(sub N), the net electric current arching from one polarity to the other; and alpha = muI(subN/phi), a flux-normalized measure of the field twist).

  11. Measurement of high energy neutrons via Lu(n,xn) reactions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henry, E.A.; Becker, J.A.; Archer, D.E.

    High energy neutrons can be assayed by the use of the nuclear diagnostic material lutetium. We are measuring the (n,xn) cross sections for natural lutetium in order to develop it as a detector material. We are applying lutetium to diagnose the high energy neutrons produced in test target/blanket systems appropriate for the Accelerator Production of Tritium Project. 3 refs., 5 figs., 1 tab.

  12. Ignition dynamics and activation energies of metallic thermites: From nano- to micron-scale particulate composites

    NASA Astrophysics Data System (ADS)

    Hunt, Emily M.; Pantoya, Michelle L.

    2005-08-01

    Ignition behaviors associated with nano- and micron-scale particulate composite thermites were studied experimentally and modeled theoretically. The experimental analysis utilized a CO2 laser ignition apparatus to ignite the front surface of compacted nickel (Ni) and aluminum (Al) pellets at varying heating rates. Ignition delay time and ignition temperature as a function of both Ni and Al particle size were measured using high-speed imaging and microthermocouples. The apparent activation energy was determined from this data using a Kissinger isoconversion method. This study shows that the activation energy is significantly lower for nano- compared with micron-scale particulate media (i.e., as low as 17.4 compared with 162.5kJ /mol, respectively). Two separate Arrhenius-type mathematical models were developed that describe ignition in the nano- and the micron-composite thermites. The micron-composite model is based on a heat balance while the nanocomposite model incorporates the energy of phase transformation in the alumina shell theorized to be an initiating step in the solid-solid diffusion reaction and uniquely appreciable in nanoparticle media. These models were found to describe the ignition of the Ni /Al alloy for a wide range of heating rates.

  13. The activation energy of stabilised/solidified contaminated soils.

    PubMed

    Chitambira, B; Al-Tabbaa, A; Perera, A S R; Yu, X D

    2007-03-15

    Developing an understanding of the time-related performance of cement-treated materials is essential in understanding their durability and long-term effectiveness. A number of models have been developed to predict this time-related performance. One such model is the maturity concept which involves use of the 'global' activation energy which derives from the Arrhenius equation. The accurate assessment of the activation energy is essential in the realistic modelling of the accelerated ageing of cement-treated soils. Experimentally, this model is applied to a series of tests performed at different elevated temperatures. Experimental work, related to the results of a time-related performance on a contaminated site in the UK treated with in situ stabilisation/solidification was carried out. Three different cement-based grouts were used on two model site soils which were both contaminated with a number of heavy metals and a hydrocarbon. Uncontaminated soils were also tested. Elevated temperatures up to 60 degrees C and curing periods up to 90 days were used. The resulting global activation energies for the uncontaminated and contaminated soils were compared. Lower values were obtained for the contaminated soils reflecting the effect of the contaminants. The resulting equivalent ages for the uncontaminated and contaminated mixes tested were 5.1-7.4 and 0.8-4.1 years, respectively. This work shows how a specific set of contaminants affect the E(a) values for particular cementitious systems and how the maturity concept can be applied to cement-treated contaminated soils.

  14. ACTIVITIES: Centimeter and Millimeter Measurements

    ERIC Educational Resources Information Center

    Bolster, L. Carey

    1974-01-01

    An activity is suggested which will give junior high school students practice in estimating and measuring in centimeters and millimeters. Three worksheets are given, one of which is a model for making a metric caliper. (LS)

  15. Measuring information-based energy and temperature of literary texts

    NASA Astrophysics Data System (ADS)

    Chang, Mei-Chu; Yang, Albert C.-C.; Eugene Stanley, H.; Peng, C.-K.

    2017-02-01

    We apply a statistical method, information-based energy, to quantify informative symbolic sequences. To apply this method to literary texts, it is assumed that different words with different occurrence frequencies are at different energy levels, and that the energy-occurrence frequency distribution obeys a Boltzmann distribution. The temperature within the Boltzmann distribution can be an indicator for the author's writing capacity as the repertory of thoughts. The relative temperature of a text is obtained by comparing the energy-occurrence frequency distributions of words collected from one text versus from all texts of the same author. Combining the relative temperature with the Shannon entropy as the text complexity, the information-based energy of the text is defined and can be viewed as a quantitative evaluation of an author's writing performance. We demonstrate the method by analyzing two authors, Shakespeare in English and Jin Yong in Chinese, and find that their well-known works are associated with higher information-based energies. This method can be used to measure the creativity level of a writer's work in linguistics, and can also quantify symbolic sequences in different systems.

  16. Iowa Developed Energy Activity Sampler (IDEAS), Grades 7-12: Social Studies.

    ERIC Educational Resources Information Center

    Simonis, Doris G.

    Described is the Social Studies component of the Iowa Developed Energy Activity Sampler (IDEAS), a multidisciplinary energy education program designed for infusion into the curriculum of grades seven through twelve. Aspects of the energy situation addressed in these lessons include resource finiteness, exponential growth, standard of living,…

  17. Measurement of the Kinetic Energy of a Body by Means of a Deformation.

    ERIC Educational Resources Information Center

    Perez, Pedro J.; And Others

    1996-01-01

    Describes a technique that measures the deformation produced in a plastic material by a falling ball in order to compute the ball's kinetic energy. Varying the parameters produces accurate results and gives students a good understanding of the measurement of energy. Combines various mechanical concepts that students have learned separately in…

  18. Measurement of Electron Density Using the Multipole Resonance Probe, Langmuir Probe and Optical Emission Spectroscopy in Low Pressure Plasmas with Different Electron Energy Distribution Functions

    NASA Astrophysics Data System (ADS)

    Oberberg, Moritz; Bibinov, Nikita; Ries, Stefan; Awakowicz, Peter; Institute of Electrical Engineering; Plasma Technology Team

    2016-09-01

    In recently publication, the young diagnostic tool Multipole Resonance Probe (MRP) for electron density measurements was introduced. It is based on active plasma resonance spectroscopy (APRS). The probe was simulated und evaluated for different devices. The geometrical and electrical symmetry simplifies the APRS model, so that the electron density can be easily calculated from the measured resonance. In this work, low pressure nitrogen mixture plasmas with different electron energy distribution functions (EEDF) are investigated. The results of the MRP measurement are compared with measurements of a Langmuir Probe (LP) and Optical Emission Spectroscopy (OES). Probes and OES measure in different regimes of kinetic electron energy. Both probes measure electrons with low kinetic energy (<10 eV), whereas the OES is influenced by electrons with high kinetic energy which are needed for transitions of molecule bands. By the determination of the absolute intensity of N2(C-B) and N2+(B-X)electron temperature and density can be calculated. In a non-maxwellian plasma, all plasma diagnostics need to be combined.

  19. Measurement of the Radiation Energy in the Radio Signal of Extensive Air Showers as a Universal Estimator of Cosmic-Ray Energy.

    PubMed

    Aab, A; Abreu, P; Aglietta, M; Ahn, E J; Al Samarai, I; Albuquerque, I F M; Allekotte, I; Allison, P; Almela, A; Alvarez Castillo, J; Alvarez-Muñiz, J; Alves Batista, R; Ambrosio, M; Aminaei, A; Anastasi, G A; Anchordoqui, L; Andringa, S; Aramo, C; Arqueros, F; Arsene, N; Asorey, H; Assis, P; Aublin, J; Avila, G; Awal, N; Badescu, A M; Baus, C; Beatty, J J; Becker, K H; Bellido, J A; Berat, C; Bertaina, M E; Bertou, X; Biermann, P L; Billoir, P; Blaess, S G; Blanco, A; Blanco, M; Blazek, J; Bleve, C; Blümer, H; Boháčová, M; Boncioli, D; Bonifazi, C; Borodai, N; Brack, J; Brancus, I; Bretz, T; Bridgeman, A; Brogueira, P; Buchholz, P; Bueno, A; Buitink, S; Buscemi, M; Caballero-Mora, K S; Caccianiga, B; Caccianiga, L; Candusso, M; Caramete, L; Caruso, R; Castellina, A; Cataldi, G; Cazon, L; Cester, R; Chavez, A G; Chiavassa, A; Chinellato, J A; Chudoba, J; Cilmo, M; Clay, R W; Cocciolo, G; Colalillo, R; Coleman, A; Collica, L; Coluccia, M R; Conceição, R; Contreras, F; Cooper, M J; Cordier, A; Coutu, S; Covault, C E; Cronin, J; Dallier, R; Daniel, B; Dasso, S; Daumiller, K; Dawson, B R; de Almeida, R M; de Jong, S J; De Mauro, G; de Mello Neto, J R T; De Mitri, I; de Oliveira, J; de Souza, V; Del Peral, L; Deligny, O; Dhital, N; Di Giulio, C; Di Matteo, A; Diaz, J C; Díaz Castro, M L; Diogo, F; Dobrigkeit, C; Docters, W; D'Olivo, J C; Dorofeev, A; Dorosti Hasankiadeh, Q; Dos Anjos, R C; Dova, M T; Ebr, J; Engel, R; Erdmann, M; Erfani, M; Escobar, C O; Espadanal, J; Etchegoyen, A; Falcke, H; Fang, K; Farrar, G; Fauth, A C; Fazzini, N; Ferguson, A P; Fick, B; Figueira, J M; Filevich, A; Filipčič, A; Fratu, O; Freire, M M; Fujii, T; García, B; Garcia-Gamez, D; Garcia-Pinto, D; Gate, F; Gemmeke, H; Gherghel-Lascu, A; Ghia, P L; Giaccari, U; Giammarchi, M; Giller, M; Głas, D; Glaser, C; Glass, H; Golup, G; Gómez Berisso, M; Gómez Vitale, P F; González, N; Gookin, B; Gordon, J; Gorgi, A; Gorham, P; Gouffon, P; Griffith, N; Grillo, A F; Grubb, T D; Guarino, F; Guedes, G P; Hampel, M R; Hansen, P; Harari, D; Harrison, T A; Hartmann, S; Harton, J L; Haungs, A; Hebbeker, T; Heck, D; Heimann, P; Herve, A E; Hill, G C; Hojvat, C; Hollon, N; Holt, E; Homola, P; Hörandel, J R; Horvath, P; Hrabovský, M; Huber, D; Huege, T; Insolia, A; Isar, P G; Jandt, I; Jansen, S; Jarne, C; Johnsen, J A; Josebachuili, M; Kääpä, A; Kambeitz, O; Kampert, K H; Kasper, P; Katkov, I; Keilhauer, B; Kemp, E; Kieckhafer, R M; Klages, H O; Kleifges, M; Kleinfeller, J; Krause, R; Krohm, N; Kuempel, D; Kukec Mezek, G; Kunka, N; Kuotb Awad, A W; LaHurd, D; Latronico, L; Lauer, R; Lauscher, M; Lautridou, P; Le Coz, S; Lebrun, D; Lebrun, P; Leigui de Oliveira, M A; Letessier-Selvon, A; Lhenry-Yvon, I; Link, K; Lopes, L; López, R; López Casado, A; Louedec, K; Lucero, A; Malacari, M; Mallamaci, M; Maller, J; Mandat, D; Mantsch, P; Mariazzi, A G; Marin, V; Mariş, I C; Marsella, G; Martello, D; Martinez, H; Martínez Bravo, O; Martraire, D; Masías Meza, J J; Mathes, H J; Mathys, S; Matthews, J; Matthews, J A J; Matthiae, G; Maurizio, D; Mayotte, E; Mazur, P O; Medina, C; Medina-Tanco, G; Meissner, R; Mello, V B B; Melo, D; Menshikov, A; Messina, S; Micheletti, M I; Middendorf, L; Minaya, I A; Miramonti, L; Mitrica, B; Molina-Bueno, L; Mollerach, S; Montanet, F; Morello, C; Mostafá, M; Moura, C A; Muller, M A; Müller, G; Müller, S; Navas, S; Necesal, P; Nellen, L; Nelles, A; Neuser, J; Nguyen, P H; Niculescu-Oglinzanu, M; Niechciol, M; Niemietz, L; Niggemann, T; Nitz, D; Nosek, D; Novotny, V; Nožka, L; Núñez, L A; Ochilo, L; Oikonomou, F; Olinto, A; Pacheco, N; Pakk Selmi-Dei, D; Palatka, M; Pallotta, J; Papenbreer, P; Parente, G; Parra, A; Paul, T; Pech, M; Pȩkala, J; Pelayo, R; Pepe, I M; Perrone, L; Petermann, E; Peters, C; Petrera, S; Petrov, Y; Phuntsok, J; Piegaia, R; Pierog, T; Pieroni, P; Pimenta, M; Pirronello, V; Platino, M; Plum, M; Porcelli, A; Porowski, C; Prado, R R; Privitera, P; Prouza, M; Quel, E J; Querchfeld, S; Quinn, S; Rautenberg, J; Ravel, O; Ravignani, D; Reinert, D; Revenu, B; Ridky, J; Risse, M; Ristori, P; Rizi, V; Rodrigues de Carvalho, W; Rodriguez Rojo, J; Rodríguez-Frías, M D; Rogozin, D; Rosado, J; Roth, M; Roulet, E; Rovero, A C; Saffi, S J; Saftoiu, A; Salazar, H; Saleh, A; Salesa Greus, F; Salina, G; Sanabria Gomez, J D; Sánchez, F; Sanchez-Lucas, P; Santos, E; Santos, E M; Sarazin, F; Sarkar, B; Sarmento, R; Sarmiento-Cano, C; Sato, R; Scarso, C; Schauer, M; Scherini, V; Schieler, H; Schmidt, D; Scholten, O; Schoorlemmer, H; Schovánek, P; Schröder, F G; Schulz, A; Schulz, J; Schumacher, J; Sciutto, S J; Segreto, A; Settimo, M; Shadkam, A; Shellard, R C; Sigl, G; Sima, O; Śmiałkowski, A; Šmída, R; Snow, G R; Sommers, P; Sonntag, S; Sorokin, J; Squartini, R; Srivastava, Y N; Stanca, D; Stanič, S; Stapleton, J; Stasielak, J; Stephan, M; Stutz, A; Suarez, F; Suarez Durán, M; Suomijärvi, T; Supanitsky, A D; Sutherland, M S; Swain, J; Szadkowski, Z; Taborda, O A; Tapia, A; Tepe, A; Theodoro, V M; Timmermans, C; Todero Peixoto, C J; Toma, G; Tomankova, L; Tomé, B; Tonachini, A; Torralba Elipe, G; Torres Machado, D; Travnicek, P; Trini, M; Ulrich, R; Unger, M; Urban, M; Valdés Galicia, J F; Valiño, I; Valore, L; van Aar, G; van Bodegom, P; van den Berg, A M; van Velzen, S; van Vliet, A; Varela, E; Vargas Cárdenas, B; Varner, G; Vasquez, R; Vázquez, J R; Vázquez, R A; Veberič, D; Verzi, V; Vicha, J; Videla, M; Villaseñor, L; Vlcek, B; Vorobiov, S; Wahlberg, H; Wainberg, O; Walz, D; Watson, A A; Weber, M; Weidenhaupt, K; Weindl, A; Welling, C; Werner, F; Widom, A; Wiencke, L; Wilczyński, H; Winchen, T; Wittkowski, D; Wundheiler, B; Wykes, S; Yang, L; Yapici, T; Yushkov, A; Zas, E; Zavrtanik, D; Zavrtanik, M; Zepeda, A; Zimmermann, B; Ziolkowski, M; Zuccarello, F

    2016-06-17

    We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8±0.7(stat)±6.7(syst)  MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principles calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.

  20. Measurement of the radiation energy in the radio signal of extensive air showers as a universal estimator of cosmic-ray energy

    DOE PAGES

    Aab, Alexander

    2016-06-14

    We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 ± 0.7 (stat) ± 6.7 (sys) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principle calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade ofmore » extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.« less

  1. Which indicators for measuring the daily physical activity? An overview on the challenges and technology limits for Telehealth applications.

    PubMed

    Tagliente, Irene; Solvoll, Terje; Trieste, Leopoldo; De Cecco, Carlo N; Murgia, Fabrizio; Bella, Sergio

    2016-09-14

    Obesity is one of the biggest drivers of preventable chronic diseases and healthcare costs in Worldwide. Different prevention activities are suggested. By monitoring daily energy expenditure (EE) could be possible make personalized diets and programming physical activity. In this, physical inactivity is one of the most important public health problems. Some studies refer the effort of the international community in promoting physical activities. Physical activity can be promoted only by increasing citizens' empowerment on taking care of their health, and it passes from the improving of individual information. Technology can offer solutions and metrics for monitoring and measuring daily activity by interacting with individuals, sharing information and feedbacks. In this study we review indicators of total energy expenditure and weaknesses of available devices in assessing these parameters. Literature review and technology testing EuNetHta core model. For the clinical aspects, it is fundamental to take into account all the factor that can influence the personal energy expenditure as: heart rate, blood pressure and thermoregulation (influenced by the body temperature). In this study we focused the attention on the importance of tools to encourage the physical activity. We made an analysis of the factor that can influence the right analysis of energy expenditure and at the same time the energy regime. A punctual monitoring of the exercise regime could be helpful in Telemedicine application as Telemonitorig. More study are needed to value the impact of physical activity tracker in Telemonitorig protocols. On the assessment of the energy expenditure, critical issues are related to the physiological data acquisition. Sensors connected with mobile devices could be important tools for disease prevention and interventions affecting health behaviors. New devices applications are potential useful for telemedicine assistance, but security of data and the related communication

  2. [Low level alpha activity measurements with pulse shape discrimination--the analytical system and its characteristics].

    PubMed

    Noguchi, M; Satoh, K; Higuchi, H

    1984-12-01

    Pulse shape discrimination of alpha and beta rays with liquid scintillation counting was investigated for the purpose of low level alpha activity measurements. Various liquid scintillators for pulse shape discrimination were examined by means of pulse rise time analysis. A new scintillator of low cost and of superior characteristics was found. The figure of merits better than 3.5 in rise time spectrum and the energy resolution better than 9% were obtained for carefully prepared samples. The background counting rate for a sample of 10 ml was reduced to 0.013 cpm/MeV in the range of alpha ray energy 5 to 7 MeV.

  3. Exercise Training and Energy Expenditure following Weight Loss.

    PubMed

    Hunter, Gary R; Fisher, Gordon; Neumeier, William H; Carter, Stephen J; Plaisance, Eric P

    2015-09-01

    This study aims to determine the effects of aerobic or resistance training on activity-related energy expenditure (AEE; kcal·d(-1)) and physical activity index (activity-related time equivalent (ARTE)) following weight loss. It was hypothesized that weight loss without exercise training would be accompanied by decreases in AEE, ARTE, and nontraining physical activity energy expenditure (nonexercise activity thermogenesis (NEAT)) and that exercise training would prevent decreases in free-living energy expenditure. One hundred forty premenopausal women had an average weight loss of 25 lb during a diet (800 kcal·d(-1)) of furnished food. One group aerobically trained 3 times per week (40 min·d(-1)), another group resistance-trained 3 times per week (10 exercises/2 sets × 10 repetitions), and the third group did not exercise. Dual-energy x-ray absorptiometry was used to measure body composition, indirect calorimetry was used to measure resting energy expenditure (REE) and walking energy expenditure, and doubly labeled water was used to measure total energy expenditure (TEE). AEE, ARTE, and nontraining physical activity energy expenditure (NEAT) were calculated. TEE, REE, and NEAT all decreased following weight loss for the no-exercise group, but not for aerobic and resistance trainers. Only REE decreased in the two exercise groups. Resistance trainers increased ARTE. HR and oxygen uptake while walking on the flat and up a grade were consistently related to TEE, AEE, NEAT, and ARTE. Exercise training prevents a decrease in energy expenditure, including free-living energy expenditure separate from exercise training, following weight loss. Resistance training increases physical activity, whereas economy/ease of walking is associated with increased TEE, AEE, NEAT, and ARTE.

  4. Estimating Am-241 activity in the body: comparison of direct measurements and radiochemical analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lynch, Timothy P.; Tolmachev, Sergei Y.; James, Anthony C.

    2009-06-01

    The assessment of dose and ultimately the health risk from intakes of radioactive materials begins with estimating the amount actually taken into the body. An accurate estimate provides the basis to best assess the distribution in the body, the resulting dose, and ultimately the health risk. This study continues the time-honored practice of evaluating the accuracy of results obtained using in vivo measurement methods and techniques. Results from the radiochemical analyses of the 241Am activity content of tissues and organs from four donors to the United States Transuranium and Uranium Registries were compared to the results from direct measurements ofmore » radioactive material in the body performed in vivo and post mortem. Two were whole body donations and two were partial body donations The skeleton was the organ with the highest deposition of 241Am activity in all four cases. The activities ranged from 30 Bq to 300 Bq. The skeletal estimates obtained from measurements over the forehead were within 20% of the radiochemistry results in three cases and differed by 78% in one case. The 241Am lung activity estimates ranged from 1 Bq to 30 Bq in the four cases. The results from the direct measurements were within 40% of the radiochemistry results in 3 cases and within a factor of 3 for the other case. The direct measurement estimates of liver activity ranged from 2 Bq to 60 Bq and were generally lower than the radiochemistry results. The results from this study suggest that the measurement methods and calibration techniques used at the In Vivo Radiobioassay and Research Facility to quantify the activity in the lungs, skeleton and liver are reasonable under the most challenging conditions where there is 241Am activity in multiple organs. These methods and techniques are comparable to those used at other Department of Energy sites. This suggests that the current in vivo methods and calibration techniques provide reasonable estimates of radioactive material in the body

  5. Energy spectra of massive two-body decay products and mass measurement

    DOE PAGES

    Agashe, Kaustubh; Franceschini, Roberto; Hong, Sungwoo; ...

    2016-04-26

    Here, we have recently established a new method for measuring the mass of unstable particles produced at hadron colliders based on the analysis of the energy distribution of a massless product from their two-body decays. The central ingredient of our proposal is the remarkable result that, for an unpolarized decaying particle, the location of the peak in the energy distribution of the observed decay product is identical to the (fixed) value of the energy that this particle would have in the rest-frame of the decaying particle, which, in turn, is a simple function of the involved masses. In addition, wemore » utilized the property that this energy distribution is symmetric around the location of peak when energy is plotted on a logarithmic scale. The general strategy was demonstrated in several specific cases, including both beyond the standard model particles, as well as for the top quark. In the present work, we generalize this method to the case of a massive decay product from a two-body decay; this procedure is far from trivial because (in general) both the above-mentioned properties are no longer valid. Nonetheless, we propose a suitably modified parametrization of the energy distribution that was used successfully for the massless case, which can deal with the massive case as well. We test this parametrization on concrete examples of energy spectra of Z bosons from the decay of a heavier supersymmetric partner of top quark (stop) into a Z boson and a lighter stop. After establishing the accuracy of this parametrization, we study a realistic application for the same process, but now including dominant backgrounds and using foreseeable statistics at LHC14, in order to determine the performance of this method for an actual mass measurement. The upshot of our present and previous work is that, in spite of energy being a Lorentz-variant quantity, its distribution emerges as a powerful tool for mass measurement at hadron colliders.« less

  6. Measured energy savings and performance of power-managed personal computers and monitors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nordman, B.; Piette, M.A.; Kinney, K.

    1996-08-01

    Personal computers and monitors are estimated to use 14 billion kWh/year of electricity, with power management potentially saving $600 million/year by the year 2000. The effort to capture these savings is lead by the US Environmental Protection Agency`s Energy Star program, which specifies a 30W maximum demand for the computer and for the monitor when in a {open_quote}sleep{close_quote} or idle mode. In this paper the authors discuss measured energy use and estimated savings for power-managed (Energy Star compliant) PCs and monitors. They collected electricity use measurements of six power-managed PCs and monitors in their office and five from two othermore » research projects. The devices are diverse in machine type, use patterns, and context. The analysis method estimates the time spent in each system operating mode (off, low-, and full-power) and combines these with real power measurements to derive hours of use per mode, energy use, and energy savings. Three schedules are explored in the {open_quotes}As-operated,{close_quotes} {open_quotes}Standardized,{close_quotes} and `Maximum` savings estimates. Energy savings are established by comparing the measurements to a baseline with power management disabled. As-operated energy savings for the eleven PCs and monitors ranged from zero to 75 kWh/year. Under the standard operating schedule (on 20% of nights and weekends), the savings are about 200 kWh/year. An audit of power management features and configurations for several dozen Energy Star machines found only 11% of CPU`s fully enabled and about two thirds of monitors were successfully power managed. The highest priority for greater power management savings is to enable monitors, as opposed to CPU`s, since they are generally easier to configure, less likely to interfere with system operation, and have greater savings. The difficulties in properly configuring PCs and monitors is the largest current barrier to achieving the savings potential from power management.« less

  7. Sensitivity evaluation of dynamic speckle activity measurements using clustering methods.

    PubMed

    Etchepareborda, Pablo; Federico, Alejandro; Kaufmann, Guillermo H

    2010-07-01

    We evaluate and compare the use of competitive neural networks, self-organizing maps, the expectation-maximization algorithm, K-means, and fuzzy C-means techniques as partitional clustering methods, when the sensitivity of the activity measurement of dynamic speckle images needs to be improved. The temporal history of the acquired intensity generated by each pixel is analyzed in a wavelet decomposition framework, and it is shown that the mean energy of its corresponding wavelet coefficients provides a suited feature space for clustering purposes. The sensitivity obtained by using the evaluated clustering techniques is also compared with the well-known methods of Konishi-Fujii, weighted generalized differences, and wavelet entropy. The performance of the partitional clustering approach is evaluated using simulated dynamic speckle patterns and also experimental data.

  8. Measuring Homework Completion in Behavioral Activation

    ERIC Educational Resources Information Center

    Busch, Andrew M.; Uebelacker, Lisa A.; Kalibatseva, Zornitsa; Miller, Ivan W.

    2010-01-01

    The aim of this study was to develop and validate an observer-based coding system for the characterization and completion of homework assignments during Behavioral Activation (BA). Existing measures of homework completion are generally unsophisticated, and there is no current measure of homework completion designed to capture the particularities…

  9. Energy Around Us. A Fall Activity Packet for Fourth Grade.

    ERIC Educational Resources Information Center

    Jackson Community Coll., MI. Dahlem Environmental Education Center.

    This instructional packet is one of 14 school environmental education programs developed for use in the classroom and at the Dahlem Environmental Education Center (DEEC) of the Jackson Community College (Michigan). Provided in the packet are pre-trip activities, field trip activities, and post-trip activities which focus on energy uses, energy…

  10. Measurements of the energy distribution of a high brightness rubidium ion beam.

    PubMed

    Ten Haaf, G; Wouters, S H W; Nijhof, D F J; Mutsaers, P H A; Vredenbregt, E J D

    2018-07-01

    The energy distribution of a high brightness rubidium ion beam, which is intended to be used as the source for a focused ion beam instrument, is measured with a retarding field analyzer. The ions are created from a laser-cooled and compressed atomic beam by two-step photoionization in which the ionization laser power is enhanced in a build-up cavity. Particle tracing simulations are performed to ensure the analyzer is able to resolve the distribution. The lowest achieved full width 50% energy spread is (0.205 ± 0.006) eV, which is measured at a beam current of 9 pA. The energy spread originates from the variation in the ionization position of the ions which are created inside an extraction electric field. This extraction field is essential to limit disorder-induced heating which can decrease the ion beam brightness. The ionization position distribution is limited by a tightly focused excitation laser beam. Energy distributions are measured for various ionization and excitation laser intensities and compared with calculations based on numerical solutions of the optical Bloch equations including ionization. A good agreement is found between measurements and calculations. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Free energy surfaces from nonequilibrium processes without work measurement

    NASA Astrophysics Data System (ADS)

    Adib, Artur B.

    2006-04-01

    Recent developments in statistical mechanics have allowed the estimation of equilibrium free energies from the statistics of work measurements during processes that drive the system out of equilibrium. Here a different class of processes is considered, wherein the system is prepared and released from a nonequilibrium state, and no external work is involved during its observation. For such "clamp-and-release" processes, a simple strategy for the estimation of equilibrium free energies is offered. The method is illustrated with numerical simulations and analyzed in the context of tethered single-molecule experiments.

  12. Implications of improved measurements of the highest energy SEPs by AMS and PAMELA

    NASA Astrophysics Data System (ADS)

    Whitman, K.; Bindi, V.; Consolandi, C.; Corti, C.; Yamashiro, B.

    2017-08-01

    Solar energetic particles (SEP) are a key target of heliophysics research, not only as exemplars of particle acceleration and transport processes that are ubiquitous in astrophysical plasmas, but also as the most intense transient radiation hazard for human and robotic space explorers. SEPs are very well-observed by spacecraft covering particle energies below several hundred MeV/nucleon. Multiple missions, stretching back over decades, have yielded a fairly complete description of SEP intensity, energy spectra, and composition up to a few hundred MeV/nucleon. SEP characteristics at higher energies are, by comparison, only poorly understood due to the relative dearth of high-energy measurements. This lack of high energy measurements has contributed to a disagreement within the heliophysics community regarding the source regions and mechanisms that accelerate particles up to GeV energies. In solar cycle 24, the Payload for Antimatter Matter Exploration and Light-nuclei Astrophysics (PAMELA) and the Alpha Magnetic Spectrometer (AMS) have been taking measurements of the highest energy SEPs from ∼ 100 MeV to the GeV. Since the literature has discussed SEP acceleration to GeV energies in terms of Ground Level Enhancements (GLE), we will review the findings for GLEs in solar cycle 23. We will discuss the models and theories that address acceleration up to the GeV and how AMS and PAMELA measurements have the potential to advance the current understanding of SEP acceleration physics. Lastly, only 1-2 GLEs have occurred during solar cycle 24, so we will explore a set of SEP events that were observed in the ⩾100 MeV GOES channels, most of which were also observed by PAMELA and AMS.

  13. Non-Arrhenius ionic conductivities in glasses due to a distribution of activation energies.

    PubMed

    Bischoff, C; Schuller, K; Beckman, S P; Martin, S W

    2012-08-17

    Previously observed non-Arrhenius behavior in fast ion conducting glasses [J. Kincs and S. W. Martin, Phys. Rev. Lett. 76, 70 (1996)] occurs at temperatures near the glass transition temperature, T(g), and is attributed to changes in the ion mobility due to ion trapping mechanisms that diminish the conductivity and result in a decreasing conductivity with increasing temperature. It is intuitive that disorder in glass will also result in a distribution of the activation energies (DAE) for ion conduction, which should increase the conductivity with increasing temperature, yet this has not been identified in the literature. In this Letter, a series of high precision ionic conductivity measurements are reported for 0.5Na(2)S + 0.5[xGeS(2) + (1-x)PS(5/2)] glasses with compositions ranging from 0 ≤ x ≤ 1. The impact of the cation site disorder on the activation energy is identified and explained using a DAE model. The absence of the non-Arrhenius behavior in other glasses is explained and it is predicted which glasses are expected to accentuate the DAE effect on the ionic conductivity.

  14. Measurements of 55Fe activity in activated steel samples with GEMPix

    NASA Astrophysics Data System (ADS)

    Curioni, A.; Dinar, N.; La Torre, F. P.; Leidner, J.; Murtas, F.; Puddu, S.; Silari, M.

    2017-03-01

    In this paper we present a novel method, based on the recently developed GEMPix detector, to measure the 55Fe content in samples of metallic material activated during operation of CERN accelerators and experimental facilities. The GEMPix, a gas detector with highly pixelated read-out, has been obtained by coupling a triple Gas Electron Multiplier (GEM) to a quad Timepix ASIC. Sample preparation, measurements performed on 45 samples and data analysis are described. The calibration factor (counts per second per unit specific activity) has been obtained via measurements of the 55Fe activity determined by radiochemical analysis of the same samples. Detection limit and sensitivity to the current Swiss exemption limit are calculated. Comparison with radiochemical analysis shows inconsistency for the sensitivity for only two samples, most likely due to underestimated uncertainties of the GEMPix analysis. An operative test phase of this technique is already planned at CERN.

  15. Novel method for measurement of transistor gate length using energy-filtered transmission electron microscopy

    NASA Astrophysics Data System (ADS)

    Lee, Sungho; Kim, Tae-Hoon; Kang, Jonghyuk; Yang, Cheol-Woong

    2016-12-01

    As the feature size of devices continues to decrease, transmission electron microscopy (TEM) is becoming indispensable for measuring the critical dimension (CD) of structures. Semiconductors consist primarily of silicon-based materials such as silicon, silicon dioxide, and silicon nitride, and the electrons transmitted through a plan-view TEM sample provide diverse information about various overlapped silicon-based materials. This information is exceedingly complex, which makes it difficult to clarify the boundary to be measured. Therefore, we propose a simple measurement method using energy-filtered TEM (EF-TEM). A precise and effective measurement condition was obtained by determining the maximum value of the integrated area ratio of the electron energy loss spectrum at the boundary to be measured. This method employs an adjustable slit allowing only electrons with a certain energy range to pass. EF-TEM imaging showed a sharp transition at the boundary when the energy-filter’s passband centre was set at 90 eV, with a slit width of 40 eV. This was the optimum condition for the CD measurement of silicon-based materials involving silicon nitride. Electron energy loss spectroscopy (EELS) and EF-TEM images were used to verify this method, which makes it possible to measure the transistor gate length in a dynamic random access memory manufactured using 35 nm process technology. This method can be adapted to measure the CD of other non-silicon-based materials using the EELS area ratio of the boundary materials.

  16. Photovoltaic energy production map of Greece based on simulated and measured data

    NASA Astrophysics Data System (ADS)

    Vokas, Georgios A.; Lagogiannis, Konstantinos V.; Papageorgas, Panagiotis; Salame, Takla

    2017-02-01

    The aim of this research is in one hand to reveal the real energy production of a medium scale Photovoltaic (PV) plant located at different sites in Greece and on the other to compare measured data to the predicted ones resulted from one well-known, PV simulation software. During the last ten years a capacity of more than 2,5 GWp of PV systems has been installed in Greece. Almost 37% of the installations are ranged from 10 to 100 kWp due to favorable Feed-in-Tariff policy pricing, according to the Greek regulation. Previous investigations proved a remarkable difference between measured and predicted energy production in Greece regarding all PV systems technologies. For the purposes of this study more than 250 medium scale PV plants have been measured and more than 850 annually energy production data series for those parks have been collected. Those data constitute a great sample that has been compared to more than 225 simulations data resulted by a well-known web software for PV systems energy yield calculations with improved solar radiation database. Additionally, in order to have a visual feeling concerning the real PV energy yield footprint in Greece, an updated map has been developed and illustrated, providing a useful tool for both business and academic purposes.

  17. Chapter 10: Peak Demand and Time-Differentiated Energy Savings Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W; Stern, Frank; Spencer, Justin

    Savings from electric energy efficiency measures and programs are often expressed in terms of annual energy and presented as kilowatt-hours per year (kWh/year). However, for a full assessment of the value of these savings, it is usually necessary to consider the measure or program's impact on peak demand as well as time-differentiated energy savings. This cross-cutting protocol describes methods for estimating the peak demand and time-differentiated energy impacts of measures implemented through energy efficiency programs.

  18. A thermal extrapolation method for the effective temperatures and internal energies of activated ions

    NASA Astrophysics Data System (ADS)

    Meot-Ner (Mautner), Michael; Somogyi, Árpád

    2007-11-01

    The internal energies of dissociating ions, activated chemically or collisionally, can be estimated using the kinetics of thermal dissociation. The thermal Arrhenius parameters can be combined with the observed dissociation rate of the activated ions using kdiss = Athermalexp(-Ea,thermal/RTeff). This Arrhenius-type relation yields the effective temperature, Teff, at which the ions would dissociate thermally at the same rate, or yield the same product distributions, as the activated ions. In turn, Teff is used to calculate the internal energy of the ions and the energy deposited by the activation process. The method yields an energy deposition efficiency of 10% for a chemical ionization proton transfer reaction and 8-26% for the surface collisions of various peptide ions. Internal energies of ions activated by chemical ionization or by gas phase collisions, and of ions produced by desorption methods such as fast atom bombardment, can be also evaluated. Thermal extrapolation is especially useful for ion-molecule reaction products and for biological ions, where other methods to evaluate internal energies are laborious or unavailable.

  19. Validity and Reliability of Fitbit Flex for Step Count, Moderate to Vigorous Physical Activity and Activity Energy Expenditure

    PubMed Central

    Sushames, Ashleigh; Edwards, Andrew; Thompson, Fintan; McDermott, Robyn; Gebel, Klaus

    2016-01-01

    Objectives To examine the validity and reliability of the Fitbit Flex against direct observation for measuring steps in the laboratory and against the Actigraph for step counts in free-living conditions and for moderate-to-vigorous physical activity (MVPA) and activity energy expenditure (AEE) overall. Methods Twenty-five adults (12 females, 13 males) wore a Fitbit Flex and an Actigraph GT3X+ during a laboratory based protocol (including walking, incline walking, running and stepping) and free-living conditions during a single day period to examine measurement of steps, AEE and MVPA. Twenty-four of the participants attended a second session using the same protocol. Results Intraclass correlations (ICC) for test-retest reliability of the Fitbit Flex were strong for walking (ICC = 0.57), moderate for stair stepping (ICC = 0.34), and weak for incline walking (ICC = 0.22) and jogging (ICC = 0.26). The Fitbit significantly undercounted walking steps in the laboratory (absolute proportional difference: 21.2%, 95%CI 13.0–29.4%), but it was more accurate, despite slightly over counting, for both jogging (6.4%, 95%CI 3.7–9.0%) and stair stepping (15.5%, 95%CI 10.1–20.9%). The Fitbit had higher coefficients of variation (Cv) for step counts compared to direct observation and the Actigraph. In free-living conditions, the average MVPA minutes were lower in the Fitbit (35.4 minutes) compared to the Actigraph (54.6 minutes), but AEE was greater from the Fitbit (808.1 calories) versus the Actigraph (538.9 calories). The coefficients of variation were similar for AEE for the Actigraph (Cv = 36.0) and Fitbit (Cv = 35.0), but lower in the Actigraph (Cv = 25.5) for MVPA against the Fitbit (Cv = 32.7). Conclusion The Fitbit Flex has moderate validity for measuring physical activity relative to direct observation and the Actigraph. Test-rest reliability of the Fitbit was dependant on activity type and had greater variation between sessions compared to the Actigraph. Physical

  20. CVD diamond detector with interdigitated electrode pattern for time-of-flight energy-loss measurements of low-energy ion bunches

    NASA Astrophysics Data System (ADS)

    Cayzac, W.; Pomorski, M.; Blažević, A.; Canaud, B.; Deslandes, D.; Fariaut, J.; Gontier, D.; Lescoute, E.; Marmouget, J. G.; Occelli, F.; Oudot, G.; Reverdin, C.; Sauvestre, J. E.; Sollier, A.; Soullié, G.; Varignon, C.; Villette, B.

    2018-05-01

    Ion stopping experiments in plasma for beam energies of few hundred keV per nucleon are of great interest to benchmark the stopping-power models in the context of inertial confinement fusion and high-energy-density physics research. For this purpose, a specific ion detector on chemical-vapor-deposition diamond basis has been developed for precise time-of-flight measurements of the ion energy loss. The electrode structure is interdigitated for maximizing its sensitivity to low-energy ions, and it has a finger width of 100 μm and a spacing of 500 μm. A short single α-particle response is obtained, with signals as narrow as 700 ps at full width at half maximum. The detector has been tested with α-particle bunches at a 500 keV per nucleon energy, showing an excellent time-of-flight resolution down to 20 ps. In this way, beam energy resolutions from 0.4 keV to a few keV have been obtained in an experimental configuration using a 100 μg/cm2 thick carbon foil as an energy-loss target and a 2 m time-of-flight distance. This allows a highly precise beam energy measurement of δE/E ≈ 0.04%-0.2% and a resolution on the energy loss of 0.6%-2.5% for a fine testing of stopping-power models.