Sample records for activities emergency clearance

  1. 77 FR 66075 - Agency Information Collection Activities; Emergency Clearance Submission for Expedited OMB Review...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-01

    ... OFFICE OF GOVERNMENT ETHICS Agency Information Collection Activities; Emergency Clearance... 201-A Ethics in Government Act Access Form AGENCY: Office of Government Ethics (OGE). ACTION... Ethics (OGE) is submitting a request to the Office of Management and Budget (OMB) for an expedited...

  2. Emergency Department Medical Clearance of Patients with Psychiatric or Behavioral Emergencies, Part 1.

    PubMed

    Tucci, Veronica Theresa; Moukaddam, Nidal; Alam, Al; Rachal, James

    2017-09-01

    Patients presenting to the emergency department with mental illness or behavioral complaints merit workup for underlying physical conditions that can trigger, mimic, or worsen psychiatric symptoms. However, interdisciplinary consensus on medical clearance is lacking, leading to wide variations in quality of care and, quite often, poor medical care. Psychiatry and emergency medicine specialty guidelines support a tailored, customized approach. This article summarizes best-practice approaches to the medical clearance of patients with psychiatric illness, tips on history taking, system reviews, clinical or physical examination, and common pitfalls in the medical clearance process. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Emergency Department Medical Clearance of Patients with Psychiatric or Behavioral Emergencies, Part 2: Special Psychiatric Populations and Considerations.

    PubMed

    Alam, Al; Rachal, James; Tucci, Veronica Theresa; Moukaddam, Nidal

    2017-09-01

    Patients who present to the emergency department (ED) with mental illness or behavioral complaints merit workup for underlying physical conditions that can trigger, mimic, or worsen psychiatric symptoms. However, there are wide variations in quality of care for these individuals. Psychiatry and emergency medicine specialty guidelines support a tailored, customized approach to patients. Our group has long advocated a dynamic comanagement approach for medical clearance in the ED, and this article summarizes best-practice approaches to the medical clearance of patients with psychiatric illness, tips on history taking, system reviews, clinical/physical examination, and common pitfalls in the medical clearance process. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Early lactate clearance for predicting active bleeding in critically ill patients with acute upper gastrointestinal bleeding: a retrospective study.

    PubMed

    Wada, Tomoki; Hagiwara, Akiyoshi; Uemura, Tatsuki; Yahagi, Naoki; Kimura, Akio

    2016-08-01

    Not all patients with upper gastrointestinal bleeding (UGIB) require emergency endoscopy. Lactate clearance has been suggested as a parameter for predicting patient outcomes in various critical care settings. This study investigates whether lactate clearance can predict active bleeding in critically ill patients with UGIB. This single-center, retrospective, observational study included critically ill patients with UGIB who met all of the following criteria: admission to the emergency department (ED) from April 2011 to August 2014; had blood samples for lactate evaluation at least twice during the ED stay; and had emergency endoscopy within 6 h of ED presentation. The main outcome was active bleeding detected with emergency endoscopy. Classification and regression tree (CART) analyses were performed using variables associated with active bleeding to derive a prediction rule for active bleeding in critically ill UGIB patients. A total of 154 patients with UGIB were analyzed, and 31.2 % (48/154) had active bleeding. In the univariate analysis, lactate clearance was significantly lower in patients with active bleeding than in those without active bleeding (13 vs. 29 %, P < 0.001). Using the CART analysis, a prediction rule for active bleeding is derived, and includes three variables: lactate clearance; platelet count; and systolic blood pressure at ED presentation. The rule has 97.9 % (95 % CI 90.2-99.6 %) sensitivity with 32.1 % (28.6-32.9 %) specificity. Lactate clearance may be associated with active bleeding in critically ill patients with UGIB, and may be clinically useful as a component of a prediction rule for active bleeding.

  5. Evaluation of an Active Clearance Control System Concept

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M.; Lattime, Scott B.; DeCastro, Jonathan A.; Oswald, Jay; Melcher, Kevin J.

    2005-01-01

    Reducing blade tip clearances through active tip clearance control in the high pressure turbine can lead to significant reductions in emissions and specific fuel consumption as well as dramatic improvements in operating efficiency and increased service life. Current engines employ scheduled cooling of the outer case flanges to reduce high pressure turbine tip clearances during cruise conditions. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, reburst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). In an effort to improve upon current thermal methods, a first generation mechanically-actuated active clearance control (ACC) system has been designed and fabricated. The system utilizes independent actuators, a segmented shroud structure, and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. Ambient temperature performance tests of this first generation ACC system assessed individual seal component leakage rates and both static and dynamic overall system leakage rates. The ability of the nine electric stepper motors to control the position of the seal carriers in both open- and closed-loop control modes for single and multiple cycles was investigated. The ability of the system to follow simulated engine clearance transients in closed-loop mode showed the system was able to track clearances to within a tight tolerance (0.001 in. error).

  6. Evaluation of an Active Clearance Control System Concept

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M.; Lattime, Scott B.; Taylor, Shawn; DeCastro, Jonathan A.; Oswald, Jay; Melcher, Kevin J.

    2005-01-01

    Reducing blade tip clearances through active tip clearance control in the high pressure turbine can lead to significant reductions in emissions and specific fuel consumption as well as dramatic improvements in operating efficiency and increased service life. Current engines employ scheduled cooling of the outer case flanges to reduce high pressure turbine tip clearances during cruise conditions. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, reburst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). In an effort to improve upon current thermal methods, a first generation mechanically-actuated active clearance control (ACC) system has been designed and fabricated. The system utilizes independent actuators, a segmented shroud structure, and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. Ambient temperature performance tests of this first generation ACC system assessed individual seal component leakage rates and both static and dynamic overall system leakage rates. The ability of the nine electric stepper motors to control the position of the seal carriers in both open- and closed-loop control modes for single and multiple cycles was investigated. The ability of the system to follow simulated engine clearance transients in closed-loop mode showed the system was able to track clearances to within a tight tolerance ( 0.001 in. error).

  7. Fuel conservation through active control of rotor clearances

    NASA Technical Reports Server (NTRS)

    Beitler, R. S.; Saunders, A. A.; Wanger, R. P.

    1980-01-01

    Under the NASA-sponsored Energy Efficient Engine (EEE) Project, technology is being developed which will significantly reduce the fuel consumption of turbofan engines for subsonic transport aircraft. One technology concept being pursued is active control of rotor tip clearances. Attention is given to rotor tip clearance considerations and an overview of preliminary study results as well as the General Electric EEE clearance control approach is presented. Finally, potential fuel savings with active control of rotor clearances for a typical EEE mission are predicted.

  8. 75 FR 43609 - Agency Information Collection Activities: Emergency Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-26

    ... SOCIAL SECURITY ADMINISTRATION Agency Information Collection Activities: Emergency Request The Social Security Administration (SSA) publishes a list of information collection packages requiring...) Social Security Administration, DCBFM, Attn: Reports Clearance Officer, 1340 Annex Building, 6401...

  9. Controls Considerations for Turbine Active Clearance Control

    NASA Technical Reports Server (NTRS)

    Melcher, Kevin J.

    2004-01-01

    This presentation discusses active control of turbine tip clearance from a control systems perspective. It is a subset of charts that were presented at the 2003 meeting of the International Society of Air Breathing Engines which was held August 31 through September 5 in Cleveland, Ohio. The associated reference paper is cited at the end of the presentation. The presentation describes active tip clearance control research being conducted by NASA to improve turbine engine systems. The target application for this effort is commercial aircraft engines. However, it is believed that the technologies developed as part of this research will benefit a broad spectrum of current and future turbomachinery. The first part of the presentation discusses the concept of tip clearance, problems associated with it, and the benefits of controlling it. It lays out a framework for implementing tip clearance controls that enables the implementation to progress from purely analytical to hardware-in-the-loop to fully experimental. And it briefly discusses how the technologies developed will be married to the previously described ACC Test Rig for hardware-in-the-loop demonstrations. The final portion of the presentation, describes one of the key technologies in some detail by presenting equations and results for a functional dynamic model of the tip clearance phenomena. As shown, the model exhibits many of the clearance dynamics found in commercial gas turbine engines. However, initial attempts to validate the model identified limitations that are being addressed to make the model more realistic.

  10. 28 CFR 524.74 - Activities clearance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., AND TRANSFER CLASSIFICATION OF INMATES Central Inmate Monitoring (CIM) System § 524.74 Activities... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Activities clearance. 524.74 Section 524... authority on all transfers, temporary releases, community activities, and escorted trips. (b) Witness...

  11. 28 CFR 524.74 - Activities clearance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., AND TRANSFER CLASSIFICATION OF INMATES Central Inmate Monitoring (CIM) System § 524.74 Activities... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Activities clearance. 524.74 Section 524... authority on all transfers, temporary releases, community activities, and escorted trips. (b) Witness...

  12. 28 CFR 524.74 - Activities clearance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., AND TRANSFER CLASSIFICATION OF INMATES Central Inmate Monitoring (CIM) System § 524.74 Activities... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Activities clearance. 524.74 Section 524... authority on all transfers, temporary releases, community activities, and escorted trips. (b) Witness...

  13. 28 CFR 524.74 - Activities clearance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., AND TRANSFER CLASSIFICATION OF INMATES Central Inmate Monitoring (CIM) System § 524.74 Activities... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Activities clearance. 524.74 Section 524... authority on all transfers, temporary releases, community activities, and escorted trips. (b) Witness...

  14. Test Rig for Evaluating Active Turbine Blade Tip Clearance Control Concepts

    NASA Technical Reports Server (NTRS)

    Lattime, Scott B.; Steinetz, Bruce M.; Robbie, Malcolm G.

    2003-01-01

    Improved blade tip sealing in the high pressure compressor and high pressure turbine can provide dramatic improvements in specific fuel consumption, time-on-wing, compressor stall margin and engine efficiency as well as increased payload and mission range capabilities of both military and commercial gas turbine engines. The preliminary design of a mechanically actuated active clearance control (ACC) system for turbine blade tip clearance management is presented along with the design of a bench top test rig in which the system is to be evaluated. The ACC system utilizes mechanically actuated seal carrier segments and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. The purpose of this active clearance control system is to improve upon current case cooling methods. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, re-burst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). The active turbine blade tip clearance control system design presented herein will be evaluated to ensure that proper response and positional accuracy is achievable under simulated high-pressure turbine conditions. The test rig will simulate proper seal carrier pressure and temperature loading as well as the magnitudes and rates of blade tip clearance changes of an actual gas turbine engine. The results of these evaluations will be presented in future works.

  15. Benefits of Improved HP Turbine Active Clearance Control

    NASA Technical Reports Server (NTRS)

    Ruiz, Rafael; Albers, Bob; Sak, Wojciech; Seitzer, Ken; Steinetz, Bruce M.

    2007-01-01

    As part of the NASA Propulsion 21 program, GE Aircraft Engines was contracted to develop an improved high pressure turbine(HPT) active clearance control (ACC) system. The system is envisioned to minimize blade tip clearances to improve HPT efficiency throughout the engine operation range simultaneously reducing fuel consumption and emissions.

  16. 78 FR 78970 - Emergency Clearance: Public Information Collection Requirements Submitted to the Office of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-27

    ... Identifier: CMS-10510] Emergency Clearance: Public Information Collection Requirements Submitted to the Office of Management and Budget (OMB); Correction AGENCY: Centers for Medicare & Medicaid Services (CMS..., Federal Register notice (document identifier: CMS-10510) entitled ``Basic Health Program Report for Health...

  17. Further Characterization of an Active Clearance Control Concept

    NASA Technical Reports Server (NTRS)

    Taylor, Shawn C.; Steinetz, Bruce M.; Oswald, Jay J.

    2007-01-01

    A new test chamber and precision hydraulic actuation system were incorporated into an active clearance control (ACC) test rig at NASA Glenn Research Center. Using the improved system, a fast-acting, mechanically-actuated, ACC concept was evaluated at engine simulated temperatures and pressure differentials up to 1140 F and 120 psig, on the basis of secondary seal leakage and kinematic controllability. During testing, the ACC concept tracked a simulated flight clearance transient profile at 1140 F, 120 psig, with a maximum error of only 0.0012 in. Comparison of average dynamic leakage of the system with average static leakage did not show significant differences between the two operating conditions. Calculated effective clearance values for the rig were approximately 0.0002 in. at 120 psig, well below the industry specified effective clearance threshold of 0.001 in.

  18. Seal Investigations of an Active Clearance Control System Concept

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M.; Taylor, Shawn; Oswald, Jay; DeCastro, Jonathan A.

    2006-01-01

    In an effort to improve upon current thermal active clearance control methods, a first generation, fast-acting mechanically actuated, active clearance control system has been designed and installed into a non-rotating test rig. In order to harvest the benefit of tighter blade tip clearances, low-leakage seals are required for the actuated carrier segments of the seal shroud to prevent excessive leakage of compressor discharge (P3) cooling air. The test rig was designed and fabricated to facilitate the evaluation of these types of seals, identify seal leakage sources, and test other active clearance control system concepts. The objective of this paper is to present both experimental and analytical investigations into the nature of the face-seal to seal-carrier interface. Finite element analyses were used to examine face seal contact pressures and edge-loading under multiple loading conditions, varied E-seal positions and two new face seal heights. The analyses indicated that moving the E-seal inward radially and reducing face seal height would lead to more uniform contact conditions between the face seal and the carriers. Lab testing confirmed that moving the balance diameter inward radially caused a decrease in overall system leakage.

  19. Active Piezoelectric Structures for Tip Clearance Management Assessed

    NASA Technical Reports Server (NTRS)

    1995-01-01

    Managing blade tip clearance in turbomachinery stages is critical to developing advanced subsonic propulsion systems. Active casing structures with embedded piezoelectric actuators appear to be a promising solution. They can control static and dynamic tip clearance, compensate for uneven deflections, and accomplish electromechanical coupling at the material level. In addition, they have a compact design. To assess the feasibility of this concept and assist the development of these novel structures, the NASA Lewis Research Center developed in-house computational capabilities for composite structures with piezoelectric actuators and sensors, and subsequently used them to simulate candidate active casing structures. The simulations indicated the potential of active casings to modify the blade tip clearance enough to improve stage efficiency. They also provided valuable design information, such as preliminary actuator configurations (number and location) and the corresponding voltage patterns required to compensate for uneven casing deformations. An active ovalization of a casing with four discrete piezoceramic actuators attached on the outer surface is shown. The center figure shows the predicted radial displacements along the hoop direction that are induced when electrostatic voltage is applied at the piezoceramic actuators. This work, which has demonstrated the capabilities of in-house computational models to analyze and design active casing structures, is expected to contribute toward the development of advanced subsonic engines.

  20. Blood lactate clearance after maximal exercise depends on active recovery intensity.

    PubMed

    Devlin, J; Paton, B; Poole, L; Sun, W; Ferguson, C; Wilson, J; Kemi, O J

    2014-06-01

    High-intensity exercise is time-limited by onset of fatigue, marked by accumulation of blood lactate. This is accentuated at maximal, all-out exercise that rapidly accumulates high blood lactate. The optimal active recovery intensity for clearing lactate after such maximal, all-out exercise remains unknown. Thus, we studied the intensity-dependence of lactate clearance during active recovery after maximal exercise. We constructed a standardized maximal, all-out treadmill exercise protocol that predictably lead to voluntary exhaustion and blood lactate concentration>10 mM. Next, subjects ran series of all-out bouts that increased blood lactate concentration to 11.5±0.2 mM, followed by recovery exercises ranging 0% (passive)-100% of the lactate threshold. Repeated measurements showed faster lactate clearance during active versus passive recovery (P<0.01), and that active recovery at 60-100% of lactate threshold was more efficient for lactate clearance than lower intensity recovery (P<0.05). Active recovery at 80% of lactate threshold had the highest rate of and shortest time constant for lactate clearance (P<0.05), whereas the response during the other intensities was graded (100%=60%>40%>passive recovery, P<0.05). Active recovery after maximal all-out exercise clears accumulated blood lactate faster than passive recovery in an intensity-dependent manner, with maximum clearance occurring at active recovery of 80% of lactate threshold.

  1. 78 FR 56898 - Emergency Clearance: Public Information Collection Requirements Submitted to the Office of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Medicare and Medicaid Services [Document Identifier: CMS-10371] Emergency Clearance: Public Information Collection Requirements Submitted to the Office of Management and Budget (OMB) AGENCY: Center for Medicare and Medicaid Services, HHS. In compliance with the requirement of section 3506(c)(2)...

  2. 78 FR 77469 - Emergency Clearance: Public Information Collection Requirements Submitted to the Office of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Medicare & Medicaid Services [Document Identifier: CMS-10510] Emergency Clearance: Public Information Collection Requirements Submitted to the Office of Management and Budget (OMB) AGENCY: Centers for Medicare & Medicaid Services, HHS. In compliance with section 3506(c)(2)(A) of the Paperwork...

  3. 78 FR 51729 - Emergency Clearance: Public Information Collection Requirements Submitted to the Office of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Medicare and Medicaid Services [Document Identifier: CMS-10496 Emergency Clearance: Public Information Collection Requirements Submitted to the Office of Management and Budget (OMB) AGENCY: Center for Medicare and Medicaid Services. In compliance with the requirement of section 3506(c)(2)(A) of...

  4. Toward a Fast-Response Active Turbine Tip Clearance Control

    NASA Technical Reports Server (NTRS)

    Melcher, Kevin J.; Kypuros, Javier A.

    2003-01-01

    This paper describes active tip clearance control research being conducted by NASA to improve turbine engine systems. The target application for this effort is commercial aircraft engines. However, technologies developed for clearance control can benefit a broad spectrum of current and future turbomachinery. The first portion of the paper addresses the research from a programmatic viewpoint. Recent studies that provide motivation for the work, identification of key technologies, and NASA's plan for addressing deficiencies in the technologies are discussed. The later portion of the paper drills down into one of the key technologies by presenting equations and results for a preliminary dynamic model of the tip clearance phenomena.

  5. 76 FR 17182 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-28

    ... Activities: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative... Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service...: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery. Abstract...

  6. Gas turbine engine active clearance control

    NASA Technical Reports Server (NTRS)

    Deveau, Paul J. (Inventor); Greenberg, Paul B. (Inventor); Paolillo, Roger E. (Inventor)

    1985-01-01

    Method for controlling the clearance between rotating and stationary components of a gas turbine engine are disclosed. Techniques for achieving close correspondence between the radial position of rotor blade tips and the circumscribing outer air seals are disclosed. In one embodiment turbine case temperature modifying air is provided in flow rate, pressure and temperature varied as a function of engine operating condition. The modifying air is scheduled from a modulating and mixing valve supplied with dual source compressor air. One source supplies relatively low pressure, low temperature air and the other source supplies relatively high pressure, high temperature air. After the air has been used for the active clearance control (cooling the high pressure turbine case) it is then used for cooling the structure that supports the outer air seal and other high pressure turbine component parts.

  7. 78 FR 76849 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-19

    ... Activities: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative... Request (ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... proposed information collection activity provides a means to garner qualitative customer and stakeholder...

  8. 77 FR 56866 - Agency Information Collection Activities: Proposed Collection; Comment Request, Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-14

    ... Collection Activities: Proposed Collection; Comment Request, Generic Clearance for Cognitive, Pilot and Field... information collection clearance that will allow BJS to conduct a variety of cognitive, pilot, and field test... new or modified data collection, BJS will engage in cognitive, pilot and field test activities to...

  9. 77 FR 56865 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-14

    ... Collection Activities: Proposed Collection; Comment Request; Generic Clearance for Cognitive, Pilot and Field... information collection clearance that will allow BJS to conduct a variety of cognitive, pilot, and field test... each new or modified data collection, BJS will engage in cognitive, pilot and field test activities to...

  10. 77 FR 56867 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-14

    ... Collection Activities: Proposed Collection; Comment Request; Generic Clearance for Cognitive, Pilot and Field... information collection clearance that will allow BJS to conduct a variety of cognitive, pilot, and field test... new or modified data collection, BJS will engage in cognitive, pilot and field test activities to...

  11. AHERA CLEARANCE AT TWENTY ABATEMENT SITES

    EPA Science Inventory

    A study was conducted during the summer of 1988 to document Asbestos Hazard Emergency Response Act (AHERA) clearance air-sampling practices and clearance concentrations of airborne asbestos at 20 asbestos-abatement sites in New Jersey. Each abatement took place in a school buildi...

  12. AHERA CLEARANCE AT TWENTY ABATEMENT SITES

    EPA Science Inventory

    A study was conducted during the summer of 1988 to document Asbestos Hazard Emergency Response Act (AHERA) clearance air sampling practices and clearance concentrations of airborne asbestos at 20 asbestos-abatement sites in New Jersey. ach abatement took place in a school buildin...

  13. Test Rig for Active Turbine Blade Tip Clearance Control Concepts: An Update

    NASA Technical Reports Server (NTRS)

    Taylor, Shawn; Steinetz, Bruce; Oswald, Jay; DeCastro, Jonathan; Melcher, Kevin

    2006-01-01

    The objective is to develop and demonstrate a fast-acting active clearance control system to improve turbine engine performance, reduce emissions, and increase service life. System studies have shown the benefits of reducing blade tip clearances in modern turbine engines. Minimizing blade tip clearances throughout the engine will contribute materially to meeting NASA's Ultra-Efficient Engine Technology (UEET) turbine engine project goals. NASA GRC is examining two candidate approaches including rub-avoidance and regeneration which are explained in subsequent slides.

  14. 76 FR 20714 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-13

    ... Activities: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative... Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under the Paperwork...: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery. Abstract...

  15. 76 FR 45573 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-29

    ... Technology Research Center survey. Abstract: The information collection activity will garner qualitative.... This type of generic clearance for qualitative information will not be used for quantitative... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service...

  16. 76 FR 41280 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-13

    ... proposed sample size, the expected response rate, methods for assessing potential non-response bias, the... Activities: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...

  17. 77 FR 69658 - Agency Information Collection Activities; Proposed Collection; Comment Request: Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-20

    ... Activities; Proposed Collection; Comment Request: Generic Clearance for Cognitive, Pilot and Field Studies...) Title of the Form/Collection: BJS Generic Clearance for Cognitive, Pilot, and Field Test Studies. (3... respondents will be involved in exploratory, field test, pilot, cognitive, and focus group work conducted...

  18. Progress on Shape Memory Alloy Actuator Development for Active Clearance Control

    NASA Technical Reports Server (NTRS)

    DeCastro, Jonathan; Melcher, Kevin; Noebe, Ronald

    2006-01-01

    Results of a numerical analysis evaluating the feasibility of high-temperature shape memory alloys (HTSMA) for active clearance control actuation in the high-pressure turbine section of a modern turbofan engine has been conducted. The prototype actuator concept considered here consists of parallel HTSMA wires attached to the shroud that is located on the exterior of the turbine case. A transient model of an HTSMA actuator was used to evaluate active clearance control at various operating points in a test bed aircraft engine simulation. For the engine under consideration, each actuator must be designed to counteract loads from 380 to 2000 lbf and displace at least 0.033 in. Design results show that an actuator comprised of 10 wires 2 in. in length is adequate for control at critical engine operating points and still exhibit acceptable failsafe operability and cycle life. A proportional-integral-derivative (PID) controller with integrator windup protection was implemented to control clearance amidst engine transients during a normal mission. Simulation results show that the control system exhibits minimal variability in clearance control performance across the operating envelope. The final actuator design is sufficiently small to fit within the limited space outside the high-pressure turbine case and is shown to consume only small amounts of bleed air to adequately regulate temperature.

  19. Novel sensors to enable closed-loop active clearance control in gas turbine engines

    NASA Astrophysics Data System (ADS)

    Geisheimer, Jonathan; Holst, Tom

    2014-06-01

    Active clearance control within the turbine section of gas turbine engines presents and opportunity within aerospace and industrial applications to improve operating efficiencies and the life of downstream components. Open loop clearance control is currently employed during the development of all new large core aerospace engines; however, the ability to measure the gap between the blades and the case and close down the clearance further presents as opportunity to gain even greater efficiencies. The turbine area is one of the harshest environments for long term placement of a sensor in addition to the extreme accuracy requirements required to enable closed loop clearance control. This paper gives an overview of the challenges of clearance measurements within the turbine as well as discusses the latest developments of a microwave sensor designed for this application.

  20. Improved drainage with active chest tube clearance.

    PubMed

    Shiose, Akira; Takaseya, Tohru; Fumoto, Hideyuki; Arakawa, Yoko; Horai, Tetsuya; Boyle, Edward M; Gillinov, A Marc; Fukamachi, Kiyotaka

    2010-05-01

    This study was performed to evaluate the efficacy of a novel chest drainage system. This system employs guide wire-based active chest tube clearance to improve drainage and maintain patency. A 32 Fr chest tube was inserted into pleural cavities of five pigs. On the left, a tube was connected to the chest canister, and on the right, the new system was inserted between the chest tube and chest canister. Acute bleeding was mimicked by periodic infusion of blood. The amount of blood drained from each chest cavity was recorded every 15 min for 2 h. After completion of the procedure, all residual blood and clots in each chest cavity were assessed. The new system remained widely patent, and the amount of drainage achieved with this system (670+/-105 ml) was significantly (P=0.01) higher than that with the standard tube (239+/-131 ml). The amount of retained pleural blood and clots with this system (150+/-107 ml) was significantly (P=0.04) lower than that with the standard tube (571+/-248 ml). In conclusion, a novel chest drainage system with active tube clearance significantly improved drainage without tube manipulations. 2010 Published by European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. 76 FR 37825 - Agency Information Collection Activities; Generic Clearance for the Collection of Qualitative...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-28

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Activities; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: U...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...

  2. 75 FR 57829 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-22

    ... Information Collection Clearance Officer, IT Enterprises Business Services Division, AES-200. [FR Doc. 2010... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Commuter...

  3. 76 FR 28500 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-17

    ... Information Collection Clearance Officer, IT Enterprises Business Services Division, AES-200. [FR Doc. 2011... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Agricultural...

  4. Radioaerosol lung clearance in patients with active pulmonary sarcoidosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobs, M.P.; Baughman, R.P.; Hughes, J.

    1985-05-01

    Pulmonary radioaerosol clearance rate of /sup 99m/Tc diethylenetriamine pentacetate (DTPA) in 14 patients with untreated sarcoidosis was compared with /sup 67/Ga lung scan and increased lymphocytes in the bronchoalveolar lavage (BAL) fluid. Nine healthy nonsmoking subjects had a mean DTPA clearance rate of 1.18%/min (range, 0.54 to 1.60%/min). Eight of 14 patients with sarcoidosis had clearance rates greater than 1.60%/min. Of those 8 patients with abnormal DTPA clearance, 4 had positive gallium scans, 4 had more than 17% lymphocytes in the BAL fluid, and 3 had both tests positive. To study the cause of abnormal DTPA clearance, 23 subjects (includingmore » 3 normal controls, all 14 patients with sarcoidosis, and 6 patients with localized disease on chest roentgenogram) underwent both DTPA clearance studies and BAL for quantitation of the amount of albumin in lung fluid. There was a positive correlation between the rate of DTPA clearance and the albumin concentration in lung fluid (r = 0.87, p less than 0.01).« less

  5. 78 FR 22020 - Agency Information Collection Activities: Requests for Comments; Clearance of New Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-12

    ... Control Number: 2120-XXXX. Title: Safety Awareness, Feedback, and Evaluation (SAFE) Program. Form Numbers: No FAA forms are associated with this collection. Type of Review: Clearance of a new information... Activities: Requests for Comments; Clearance of New Approval of Information Collection: Safety Awareness...

  6. JT9D-70/59 Improved High Pressure Turbine Active Clearance Control System. [for specific fuel consumption improvement

    NASA Technical Reports Server (NTRS)

    Gaffin, W. O.

    1979-01-01

    The JT9D-70/59 high pressure turbine active clearance control system was modified to provide reduction of blade tip clearance when the system is activated during cruise operation. The modification increased the flow capacity and air impingement effectiveness of the cooling air manifold to augment turbine case shrinkage capability, and increased responsiveness of the airseal clearance to case shrinkage. The simulated altitude engine testing indicated a significant improvement in specific fuel consumption with the modified system. A 1000 cycle engine endurance test showed no unusual wear or performance deterioration effects on the engine or the clearance control system. Rig tests indicated that the air impingement and seal support configurations used in the engine tests are near optimum.

  7. Phosphatidylserine-mediated platelet clearance by endothelium decreases platelet aggregates and procoagulant activity in sepsis.

    PubMed

    Ma, Ruishuang; Xie, Rui; Yu, Chengyuan; Si, Yu; Wu, Xiaoming; Zhao, Lu; Yao, Zhipeng; Fang, Shaohong; Chen, He; Novakovic, Valerie; Gao, Chunyan; Kou, Junjie; Bi, Yayan; Thatte, Hemant S; Yu, Bo; Yang, Shufen; Zhou, Jin; Shi, Jialan

    2017-07-10

    The mechanisms that eliminate activated platelets in inflammation-induced disseminated intravascular coagulation (DIC) in micro-capillary circulation are poorly understood. This study explored an alternate pathway for platelet disposal mediated by endothelial cells (ECs) through phosphatidylserine (PS) and examined the effect of platelet clearance on procoagulant activity (PCA) in sepsis. Platelets in septic patients demonstrated increased levels of surface activation markers and apoptotic vesicle formation, and also formed aggregates with leukocytes. Activated platelets adhered were and ultimately digested by ECs in vivo and in vitro. Blocking PS on platelets or αvβ3 integrin on ECs attenuated platelet clearance resulting in increased platelet count in a mouse model of sepsis. Furthermore, platelet removal by ECs resulted in a corresponding decrease in platelet-leukocyte complex formation and markedly reduced generation of factor Xa and thrombin on platelets. Pretreatment with lactadherin significantly increased phagocytosis of platelets by approximately 2-fold, diminished PCA by 70%, prolonged coagulation time, and attenuated fibrin formation by 50%. Our results suggest that PS-mediated clearance of activated platelets by the endothelium results in an anti-inflammatory, anticoagulant, and antithrombotic effect that contribute to maintaining platelet homeostasis during acute inflammation. These results suggest a new therapeutic target for impeding the development of DIC.

  8. 77 FR 47492 - Agency Information Collection Activities: Requests for Comments; Clearance of a New Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-08

    ... collection. This is a new generic clearance for the purpose of gathering customer satisfaction data directly from customers for a wide variety of services. DATES: Written comments should be submitted by October 9... Activities: Requests for Comments; Clearance of a New Approval of Information Collection: FAA Customer...

  9. 78 FR 5855 - Agency Information Collection Activities: Requests for Comments; Clearance of a New Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-28

    ... generic clearance for the purpose of gathering customer satisfaction data directly from customers for a... Activities: Requests for Comments; Clearance of a New Approval of Information Collection: FAA Customer... INFORMATION: OMB Control Number: 2120-XXXX Title: FAA Customer Service Surveys Form Numbers: There are no FAA...

  10. A Parametric Study of Actuator Requirements for Active Turbine Tip Clearance Control of a Modern High Bypass Turbofan Engine

    NASA Technical Reports Server (NTRS)

    Kratz, Jonathan L.; Chapman, Jeffryes W.; Guo, Ten-Huei

    2017-01-01

    The efficiency of aircraft gas turbine engines is sensitive to the distance between the tips of its turbine blades and its shroud, which serves as its containment structure. Maintaining tighter clearance between these components has been shown to increase turbine efficiency, increase fuel efficiency, and reduce the turbine inlet temperature, and this correlates to a longer time-on-wing for the engine. Therefore, there is a desire to maintain a tight clearance in the turbine, which requires fast response active clearance control. Fast response active tip clearance control will require an actuator to modify the physical or effective tip clearance in the turbine. This paper evaluates the requirements of a generic active turbine tip clearance actuator for a modern commercial aircraft engine using the Commercial Modular Aero-Propulsion System Simulation 40k (C-MAPSS40k) software that has previously been integrated with a dynamic tip clearance model. A parametric study was performed in an attempt to evaluate requirements for control actuators in terms of bandwidth, rate limits, saturation limits, and deadband. Constraints on the weight of the actuation system and some considerations as to the force which the actuator must be capable of exerting and maintaining are also investigated. From the results, the relevant range of the evaluated actuator parameters can be extracted. Some additional discussion is provided on the challenges posed by the tip clearance control problem and the implications for future small core aircraft engines.

  11. American Association for Emergency Psychiatry Task Force on Medical Clearance of Adult Psychiatric Patients. Part II: Controversies over Medical Assessment, and Consensus Recommendations.

    PubMed

    Wilson, Michael P; Nordstrom, Kimberly; Anderson, Eric L; Ng, Anthony T; Zun, Leslie S; Peltzer-Jones, Jennifer M; Allen, Michael H

    2017-06-01

    The emergency medical evaluation of psychiatric patients presenting to United States emergency departments (ED), usually termed "medical clearance," often varies between EDs. A task force of the American Association for Emergency Psychiatry (AAEP), consisting of physicians from emergency medicine, physicians from psychiatry and a psychologist, was convened to form consensus recommendations for the medical evaluation of psychiatric patients presenting to U.S.EDs. The task force reviewed existing literature on the topic of medical evaluation of psychiatric patients in the ED and then combined this with expert consensus. Consensus was achieved by group discussion as well as iterative revisions of the written document. The document was reviewed and approved by the AAEP Board of Directors. Eight recommendations were formulated. These recommendations cover various topics in emergency medical examination of psychiatric patients, including goals of medical screening in the ED, the identification of patients at low risk for co-existing medical disease, key elements in the ED evaluation of psychiatric patients including those with cognitive disorders, specific language replacing the term "medical clearance," and the need for better science in this area. The evidence indicates that a thorough history and physical examination, including vital signs and mental status examination, are the minimum necessary elements in the evaluation of psychiatric patients. With respect to laboratory testing, the picture is less clear and much more controversial.

  12. American Association for Emergency Psychiatry Task Force on Medical Clearance of Adult Psychiatric Patients. Part II: Controversies over Medical Assessment, and Consensus Recommendations

    PubMed Central

    Wilson, Michael P.; Nordstrom, Kimberly; Anderson, Eric L.; Ng, Anthony T.; Zun, Leslie S.; Peltzer-Jones, Jennifer M.; Allen, Michael H.

    2017-01-01

    Introduction The emergency medical evaluation of psychiatric patients presenting to United States emergency departments (ED), usually termed “medical clearance,” often varies between EDs. A task force of the American Association for Emergency Psychiatry (AAEP), consisting of physicians from emergency medicine, physicians from psychiatry and a psychologist, was convened to form consensus recommendations for the medical evaluation of psychiatric patients presenting to U.S.EDs. Methods The task force reviewed existing literature on the topic of medical evaluation of psychiatric patients in the ED and then combined this with expert consensus. Consensus was achieved by group discussion as well as iterative revisions of the written document. The document was reviewed and approved by the AAEP Board of Directors. Results Eight recommendations were formulated. These recommendations cover various topics in emergency medical examination of psychiatric patients, including goals of medical screening in the ED, the identification of patients at low risk for co-existing medical disease, key elements in the ED evaluation of psychiatric patients including those with cognitive disorders, specific language replacing the term “medical clearance,” and the need for better science in this area. Conclusion The evidence indicates that a thorough history and physical examination, including vital signs and mental status examination, are the minimum necessary elements in the evaluation of psychiatric patients. With respect to laboratory testing, the picture is less clear and much more controversial. PMID:28611885

  13. Active clearance control system for a turbomachine

    NASA Technical Reports Server (NTRS)

    Johnston, R. P.; Knapp, M. H.; Coulson, C. E. (Inventor)

    1982-01-01

    An axial compressor is provided with a cooling air manifold surrounding a portion of the shroud, and means for bleeding air from the compressor to the manifold for selectively flowing it in a modulating manner axially along the outer side of the stator/shroud to cool and shrink it during steady state operating conditions so as to obtain minimum shroud/rotor clearance conditions. Provision is also made to selectively divert the flow of cooling air from the manifold during transient periods of operation so as to alter the thermal growth or shrink rate of the stator/shroud and result in adequate clearance with the compressor rotor.

  14. 77 FR 29748 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-18

    ... for Commercial Space Transportation (AST), that a license applicant's proposed activities meet... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Commercial Space...

  15. 76 FR 53023 - Agency Information Collection Activities: Requests for Comments; Clearance of New Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-24

    ... Activities: Requests for Comments; Clearance of New Approval of Information Collection: Activation of Ice... requirement imposed by the new rule ``Part 121 Activation of Ice Protection''. The NPRM for that rule was...: Activation of Ice Protection Rule--Flight Manual Requirements. Form Numbers: There are no FAA forms...

  16. 77 FR 51608 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-24

    ... Administrator for Commercial Space Transportation (AST), that a license applicant's proposed activities meet... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Commercial Space...

  17. A Study on the Requirements for Fast Active Turbine Tip Clearance Control Systems

    NASA Technical Reports Server (NTRS)

    DeCastro, Jonathan A.; Melcher, Kevin J.

    2004-01-01

    This paper addresses the requirements of a control system for active turbine tip clearance control in a generic commercial turbofan engine through design and analysis. The control objective is to articulate the shroud in the high pressure turbine section in order to maintain a certain clearance set point given several possible engine transient events. The system must also exhibit reasonable robustness to modeling uncertainties and reasonable noise rejection properties. Two actuators were chosen to fulfill such a requirement, both of which possess different levels of technological readiness: electrohydraulic servovalves and piezoelectric stacks. Identification of design constraints, desired actuator parameters, and actuator limitations are addressed in depth; all of which are intimately tied with the hardware and controller design process. Analytical demonstrations of the performance and robustness characteristics of the two axisymmetric LQG clearance control systems are presented. Takeoff simulation results show that both actuators are capable of maintaining the clearance within acceptable bounds and demonstrate robustness to parameter uncertainty. The present model-based control strategy was employed to demonstrate the tradeoff between performance, control effort, and robustness and to implement optimal state estimation in a noisy engine environment with intent to eliminate ad hoc methods for designing reliable control systems.

  18. 76 FR 36168 - Agency Information Collection Activities; Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-21

    ... Transportation (FAA/AST) that the proposed activity meets applicable public safety, national security, and... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities; Requests for Comments; Clearance of Renewed Approval of Information Collection; Commercial Space...

  19. 76 FR 54285 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-31

    ... to the FAA Office of Commercial Space Transportation (FAA/ AST) that the proposed activity meets... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Commercial Space...

  20. 76 FR 61360 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-04

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential... Activities: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative... Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under the Paperwork...

  1. High-Clearance Six-Wheel Suspension

    NASA Technical Reports Server (NTRS)

    Bickler, Donald B.

    1992-01-01

    Multilevered suspension system gives body of vehicle high clearance and allows wheels to be steered independently. Suspension linkages above wheels enable body to skim over obstacles as high as wheel. Levers and independently steered wheels enable vehicle to climb steps 1 1/2 wheel diameters high and cross gaps 1 3/4 wide. Adaptable to off-the-road recreational vehicles, military scout vehicles, and robotic emergency vehicles.

  2. CF6 Jet Engine Performance Improvement: High Pressure Turbine Active Clearance Control

    NASA Technical Reports Server (NTRS)

    Rich, S. E.; Fasching, W. A.

    1982-01-01

    An active clearance control system was developed which reduces fuel consumption and performance degradation. This system utilizes compressor discharge air during takeoff and fan discharge air during cruise to impinge on the shroud structure to improve the thermal response. The system was evaluated in component and engine tests. The test results demonstrated a performance improvement of 0.7 percent in cruise SFC.

  3. Intelligent Engine Systems: HPT Clearance Control

    NASA Technical Reports Server (NTRS)

    2008-01-01

    The Advanced Thermally Actuated Clearance Control System underwent several studies. Improved flow path isolation quantified what can be gained by making the HPT case nearly adiabatic. The best method of heat transfer was established, and finally two different borrowed air cooling circuits were evaluated to be used for the HPT Active Clearance Control System.

  4. 78 FR 21919 - Agency Information Collection Activities; Comment Request; Generic Clearance for Federal Student...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-12

    ... DEPARTMENT OF EDUCATION [Docket No. ED-2013-ICCD-0045] Agency Information Collection Activities; Comment Request; Generic Clearance for Federal Student Aid Customer Satisfaction Surveys and Focus Groups... Customer Satisfaction Surveys and Focus Groups Master Plan. OMB Control Number: 1845-0045. Type of Review...

  5. 76 FR 30753 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-26

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Special Awareness...: [email protected] . SUPPLEMENTARY INFORMATION: OMB Control Number: 2120-0734. Title: Special Awareness...

  6. 78 FR 66097 - Agency Information Collection Activities: Requests for Comments; Clearance of New Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-04

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities: Requests for Comments; Clearance of New Approval of Information Collection: Safety Awareness, Feedback, and Evaluation (SAFE) Program AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice...

  7. Hepatic drug clearance following traumatic injury.

    PubMed

    Slaughter, R L; Hassett, J M

    1985-11-01

    Trauma is a complex disease state associated with physiologic changes that have the potential to alter hepatic drug clearance mechanisms. These responses include alterations in hepatic blood flow, reduction in hepatic microsomal activity, reduction in hepatic excretion processes, and changes in protein binding. Hepatic blood flow is influenced by sympathomimetic activity. Both animal and human studies demonstrate an initial reduction and subsequent increase in hepatic blood flow, which coincides with an observed increase and subsequent return to normal in serum catecholamine concentrations. Unfortunately, there are no human studies that address the importance these findings may have to the clearance processes of high intrinsic clearance compounds. Animal studies of trauma indicate that hepatic microsomal activity is depressed during the post-traumatic period. Reduction in the hepatic clearance of antipyrine, a model low intrinsic compound, has also been demonstrated in animal models of trauma. In addition to these effects, hepatic excretion of substances such as indocyanine green and bilirubin have been demonstrated to be impaired in both traumatized animals and humans. Finally, substantial increases in the serum concentration of the binding protein alpha 1-acid glycoprotein occur in trauma patients. This has been reported to be associated with subsequent decreases in the free fraction of lidocaine and quinidine. In addition to changing serum drug concentration/response relationships, the pharmacokinetic behavior of drugs bound to alpha 1-acid glycoprotein should also change. Preliminary observations in our laboratory in a dog model of surgically-induced trauma have shown a reduction in the total clearance of lidocaine and reduction in free lidocaine concentration.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. 76 FR 19359 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-07

    ... Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery. Abstract...

  9. 76 FR 54286 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-31

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: License Requirements for Operation of a Launch Site AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice...

  10. 78 FR 29427 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-20

    ... provide annual Management Information System testing information, and to communicate with entities subject... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Anti-Drug Program...

  11. 78 FR 31626 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-24

    ... provide annual Management Information System testing information, and to communicate with entities subject... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Anti-Drug Program...

  12. 76 FR 66348 - Agency Information Collection Activities; Requests for Comments: Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-26

    ... private sources. DATES: Written comments should be submitted by November 25, 2011. FOR FURTHER INFORMATION... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities; Requests for Comments: Clearance of Renewed Approval of Information Collection; Aviation...

  13. 76 FR 72236 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-22

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: ACSEP Evaluation... information collection. The information is collected from holders of FAA production approvals and selected...

  14. 76 FR 55078 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-06

    ...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for.... SUPPLEMENTARY INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service...

  15. 76 FR 39893 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-07

    ...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery.... SUPPLEMENTARY INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service...

  16. 76 FR 66346 - Agency Information Collection Activities; Requests for Comments: Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-26

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities; Requests for Comments: Clearance of Renewed Approval of Information Collection; Organization... information collection. The Federal Register Notice with a 60-day comment period soliciting comments on the...

  17. 76 FR 53023 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-24

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Organization... information collection. This information collection involves certain organizations applying to perform...: Renewal of an information collection. Background: Subpart D to part 183 establishes the Organization...

  18. 76 FR 10626 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-25

    ... Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under...: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery. Abstract...

  19. 75 FR 57828 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-22

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Flight Engineers and Flight Navigators AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice and request... information collection. Information collected is used to determine certification eligibility of Flight...

  20. 78 FR 22022 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-12

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Airport Noise... respondents are those airport operators voluntarily submitting noise exposure maps and noise compatibility....gov . SUPPLEMENTARY INFORMATION: OMB Control Number: 2120-0517. Title: Airport Noise Compatibility...

  1. 77 FR 4390 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-27

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: ACSEP Evaluation... information collection. The Federal Register Notice with a 60-day comment period soliciting comments on the...

  2. Cerebrospinal Fluid Clearance in Alzheimer Disease Measured with Dynamic PET.

    PubMed

    de Leon, Mony J; Li, Yi; Okamura, Nobuyuki; Tsui, Wai H; Saint-Louis, Les A; Glodzik, Lidia; Osorio, Ricardo S; Fortea, Juan; Butler, Tracy; Pirraglia, Elizabeth; Fossati, Silvia; Kim, Hee-Jin; Carare, Roxana O; Nedergaard, Maiken; Benveniste, Helene; Rusinek, Henry

    2017-09-01

    Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing the cribriform plate, human CSF clearance pathways are not well characterized. Dynamic PET with 18 F-THK5117, a tracer for tau pathology, was used to estimate the ventricular CSF time-activity as a biomarker for CSF clearance. We tested 3 hypotheses: extracranial CSF is detected at the superior turbinates; CSF clearance is reduced in AD; and CSF clearance is inversely associated with amyloid deposition. Methods: Fifteen subjects, 8 with AD and 7 normal control volunteers, were examined with 18 F-THK5117. Ten subjects additionally underwent 11 C-Pittsburgh compound B ( 11 C-PiB) PET scanning, and 8 were 11 C-PiB-positive. Ventricular time-activity curves of 18 F-THK5117 were used to identify highly correlated time-activity curves from extracranial voxels. Results: For all subjects, the greatest density of CSF-positive extracranial voxels was in the nasal turbinates. Tracer concentration analyses validated the superior nasal turbinate CSF signal intensity. AD patients showed ventricular tracer clearance reduced by 23% and 66% fewer superior turbinate CSF egress sites. Ventricular CSF clearance was inversely associated with amyloid deposition. Conclusion: The human nasal turbinate is part of the CSF clearance system. Lateral ventricle and superior nasal turbinate CSF clearance abnormalities are found in AD. Ventricular CSF clearance reductions are associated with increased brain amyloid depositions. These data suggest that PET-measured CSF clearance is a biomarker of potential interest in AD and other neurodegenerative diseases. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  3. Dual clearance squeeze film damper

    NASA Technical Reports Server (NTRS)

    Fleming, D. P. (Inventor)

    1985-01-01

    A dual clearance hydrodynamic liquid squeeze film damper for a gas turbine engine is described. Under normal operating conditions, the device functions as a conventional squeeze film damper, using only one of its oil films. When an unbalance reaches abusive levels, as may occur with a blade loss or foreign object damage, a second, larger clearance film becomes active, controlling vibration amplitudes in a near optimum manner until the engine can be safely shut down and repaired.

  4. 78 FR 40262 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-03

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Aircraft Noise.... 76, page 23628. This collection ensures that U.S. operators have proper noise certification...: 2120-0737. Title: Aircraft Noise Certification Documents for International Operations. Form Numbers...

  5. 76 FR 47287 - Agency Information Collection Activities: Requests for Comments; Clearance of a New Information...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-04

    ... Activities: Requests for Comments; Clearance of a New Information Collection: Commercial Aviation Safety Team... Commercial Aviation Safety Team (CAST) safety enhancements (SEs) from certificate holders conducting....gov . SUPPLEMENTARY INFORMATION: OMB Control Number: 2120-XXXX. Title: Commercial Aviation Safety Team...

  6. 76 FR 4743 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-26

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection(s): NAS Data... information collection. The Federal Register Notice with a 60-day comment period soliciting comments on the...

  7. 77 FR 47491 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-08

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Flight Simulation... simulation training. DATES: Written comments should be submitted by September 7, 2012. FOR FURTHER... INFORMATION: OMB Control Number: 2120-0680. Title: Flight Simulation Device Initial and Continuing...

  8. 76 FR 20804 - Agency Information Collection Activities: Requests for Comments; Clearance of a Renewed Approval...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-13

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary [Docket No. DOT-OST-2011-0057] Agency Information Collection Activities: Requests for Comments; Clearance of a Renewed Approval of Information Collection(s): Procedures for Transportation Workplace Drug and Alcohol Testing Programs AGENCY: Office of...

  9. 77 FR 40404 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-09

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Advanced... about our intention to request the Office of Management and Budget (OMB) approval to renew an information collection. The Advanced Qualification Program (AQP) incorporates data driven quality control...

  10. 78 FR 75670 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-12

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Advanced... about our intention to request the Office of Management and Budget (OMB) approval to renew an information collection. The Advanced Qualification Program uses data driven quality control processes for...

  11. 78 FR 23628 - Agency Information Collection Activities; Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-19

    ... Activities; Requests for Comments; Clearance of Renewed Approval of Information Collection: Aircraft Noise... to renew an information collection. This collection ensures that U.S. operators have proper noise...: OMB Control Number: 2120-073. Title: Aircraft Noise Certification Documents for International...

  12. 76 FR 30421 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-25

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Airport Noise... 13266. The respondents are those airport operators voluntarily submitting noise exposure maps and noise[email protected] . SUPPLEMENTARY INFORMATION: OMB Control Number: 2120-0517. Title: Airport Noise...

  13. 75 FR 52803 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-27

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Maintenance, Preventative Maintenance, Rebuilding and Alteration AGENCY: Federal Aviation Administration (FAA), DOT. ACTION... invites public comments about our intention to request the Office of Management and Budget (OMB) approval...

  14. 77 FR 60166 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-02

    ...: 2120-0018. Title: Certification Procedures for Products and Parts. Form Numbers: FAA Forms 8110-12... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Certification Procedures for Products and Parts AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice and...

  15. System-Level Design of a Shape Memory Alloy Actuator for Active Clearance Control in the High-Pressure Turbine

    NASA Technical Reports Server (NTRS)

    DeCastro, Jonathan A.; Melcher, Kevin J.; Noebe, Ronald D.

    2005-01-01

    This paper describes results of a numerical analysis evaluating the feasibility of high-temperature shape memory alloys (HTSMA) for active clearance control actuation in the high-pressure turbine section of a modern turbofan engine. The prototype actuator concept considered here consists of parallel HTSMA wires attached to the shroud that is located on the exterior of the turbine case. A transient model of an HTSMA actuator was used to evaluate active clearance control at various operating points in a test bed aircraft engine simulation. For the engine under consideration, each actuator must be designed to counteract loads from 380 to 2000 lbf and displace at least 0.033 inches. Design results show that an actuator comprised of 10 wires 2 inches in length is adequate for control at critical engine operating points and still exhibits acceptable failsafe operability and cycle life. A proportional-integral-derivative (PID) controller with integrator windup protection was implemented to control clearance amidst engine transients during a normal mission. Simulation results show that the control system exhibits minimal variability in clearance control performance across the operating envelope. The final actuator design is sufficiently small to fit within the limited space outside the high-pressure turbine case and is shown to consume only small amounts of bleed air to adequately regulate temperature.

  16. Creatinine clearance test

    MedlinePlus

    Serum creatinine clearance; Kidney function - creatinine clearance; Renal function - creatinine clearance ... the body entirely by the kidneys. If kidney function is abnormal, creatinine level increases in the blood ...

  17. 77 FR 29748 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-18

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Flight Simulation... obtained and maintained by those who conduct flight simulation training. DATES: Written comments should be... Simulation Device Initial and Continuing Qualification and Use. Form Numbers: There are no FAA forms...

  18. 78 FR 38794 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-27

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Competition Plans... that a covered airport submit a written competition plan to the Secretary/Administrator in order to... INFORMATION: OMB Control Number: 2120-0661. Title: Competition Plans, Passenger Facility Charges. Form Numbers...

  19. 76 FR 53528 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Advanced... about our intention to request the Office of Management and Budget (OMB) approval for to renew an... Advanced Qualification Program (AQP) incorporates data driven quality control processes for validating and...

  20. 78 FR 5857 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-28

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Airport Noise... information collection. The respondents are those airport operators voluntarily submitting noise exposure maps and noise compatibility programs to the FAA for review and approval. DATES: Written comments should be...

  1. 76 FR 81008 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-27

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Training and..., 2011, vol. 76, no. 207, page 66349. The rule allows some experienced pilots who would otherwise qualify...: 2120-0600 . Title: Training and Qualification Requirements for Check Airmen and Flight Instructors...

  2. 77 FR 36330 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-18

    ... certificates and associated ratings. Pilot schools train private, commercial, flight instructor, and airline transport pilots, along with training for associated ratings in various types of aircraft. The form is also... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Pilot Schools...

  3. 78 FR 5858 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-28

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Operations... intention to request the Office of Management and Budget (OMB) approval for to renew an information collection. The FAA assesses the information collected and issues operations specifications to foreign air...

  4. 78 FR 5856 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-28

    ... Title: Certification Procedures for Products and Parts Form Numbers: FAA Forms 8110-12, 8130-1, 8130-6... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Certification Procedures for Products and Parts AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice and...

  5. 75 FR 59320 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-27

    ... Number: 2120-0018. Title: Certification Procedures for Products and Parts. Form Numbers: FAA Forms 8110... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection(s): Certification Procedures for Products and Parts AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice and...

  6. Renal Clearance: Using an Interactive Activity to Visualize a Tricky Concept

    ERIC Educational Resources Information Center

    Hull, Kerry

    2016-01-01

    Renal clearance, the volume of blood cleared of a substance in a particular time period, is commonly recognized as one of the most difficult concepts in physiology. This difficulty may in part reflect the quantitative nature of renal clearance since many life sciences majors perceive that mathematics is irrelevant to their discipline. Students may…

  7. 77 FR 20093 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-03

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Pilot Schools... information on FAA Form 8420-8, Application for Pilot School Certificates, is required from applicants who wish to be issued pilot school certificates and associated ratings. DATES: Written comments should be...

  8. 75 FR 72858 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-26

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: High Density... records of slot transfers at High Density Traffic Airports. The information is provided by air carriers and commuter operators, or other persons holding a slot at High Density Airports. DATES: Written...

  9. 75 FR 52802 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-27

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: High Density... maintain accurate records of slot transfers at High Density Traffic Airports. The information is provided by air carriers and commuter operators, or other persons holding a slot at High Density Airports...

  10. 76 FR 36167 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-21

    ... INFORMATION: OMB Control Number: 2120-0042. Title: Aircraft Registration. Form Numbers: FAA Forms 8050-1, 8050.../or revocation of registration. The information collected is used by the FAA to register an aircraft... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Aircraft...

  11. TAM receptors in apoptotic cell clearance, autoimmunity, and cancer.

    PubMed

    Nguyen, Khanh-Quynh; Tsou, Wen-I; Kotenko, Sergei; Birge, Raymond B

    2013-08-01

    Receptor tyrosine kinases, Tyro-3, Axl and Mer, collectively designated as TAM, are involved in the clearance of apoptotic cells. TAM ligands, Gas6 and Protein S, bind to the surfaces of apoptotic cells, and at the same time, interact directly with TAM expressed on phagocytes, impacting the engulfment and clearance of apoptotic cells and debris. The well-tuned and balanced actions of TAM may affect a variety of human pathologies including autoimmunity, retinal degeneration, and cancer. This article emphasizes some of the emerging findings and mechanistic insights into TAM functions that are clinically relevant and possibly therapeutically targeted.

  12. 76 FR 74840 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-01

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Notice of Landing... following collection of information was published on September 23, 2011, vol. 76, no. 185, pages 59185-59186. FAA Form 7480-1 (Notice of Landing Area Proposal) is used to collect information about any...

  13. 78 FR 22021 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-12

    ..., page 71473. FAA Form 7480-1 (Notice of Landing Area Proposal) is used to collect information about any... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Notice of Landing... information collection. The Federal Register Notice with a 60-day comment period soliciting [[Page 22022...

  14. Voluntary Exercise Promotes Glymphatic Clearance of Amyloid Beta and Reduces the Activation of Astrocytes and Microglia in Aged Mice

    PubMed Central

    He, Xiao-fei; Liu, Dong-xu; Zhang, Qun; Liang, Feng-ying; Dai, Guang-yan; Zeng, Jin-sheng; Pei, Zhong; Xu, Guang-qing; Lan, Yue

    2017-01-01

    Age is characterized by chronic inflammation, leading to synaptic dysfunction and dementia because the clearance of protein waste is reduced. The clearance of proteins depends partly on the permeation of the blood–brain barrier (BBB) or on the exchange of water and soluble contents between the cerebrospinal fluid (CSF) and the interstitial fluid (ISF). A wealth of evidence indicates that physical exercise improves memory and cognition in neurodegenerative diseases during aging, such as Alzheimer’s disease (AD), but the influence of physical training on glymphatic clearance, BBB permeability and neuroinflammation remains unclear. In this study, glymphatic clearance and BBB permeability were evaluated in aged mice using in vivo two-photon imaging. The mice performed voluntary wheel running exercise and their water-maze cognition was assessed; the expression of the astrocytic water channel aquaporin 4 (AQP4), astrocyte and microglial activation, and the accumulation of amyloid beta (Aβ) were evaluated with immunofluorescence or an enzyme-linked immunosorbent assay (ELISA); synaptic function was investigated with Thy1–green fluorescent protein (GFP) transgenic mice and immunofluorescent staining. Voluntary wheel running significantly improved water-maze cognition in the aged mice, accelerated the efficiency of glymphatic clearance, but which did not affect BBB permeability. The numbers of activated astrocytes and microglia decreased, AQP4 expression increased, and the distribution of astrocytic AQP4 was rearranged. Aβ accumulation decreased, whereas dendrites, dendritic spines and postsynaptic density protein (PSD95) increased. Our study suggests that voluntary wheel running accelerated glymphatic clearance but not BBB permeation, improved astrocytic AQP4 expression and polarization, attenuated the accumulation of amyloid plaques and neuroinflammation, and ultimately protected mice against synaptic dysfunction and a decline in spatial cognition. These data

  15. Integrated Turbine Tip Clearance and Gas Turbine Engine Simulation

    NASA Technical Reports Server (NTRS)

    Chapman, Jeffryes W.; Kratz, Jonathan; Guo, Ten-Huei; Litt, Jonathan

    2016-01-01

    Gas turbine compressor and turbine blade tip clearance (i.e., the radial distance between the blade tip of an axial compressor or turbine and the containment structure) is a major contributing factor to gas path sealing, and can significantly affect engine efficiency and operational temperature. This paper details the creation of a generic but realistic high pressure turbine tip clearance model that may be used to facilitate active tip clearance control system research. This model uses a first principles approach to approximate thermal and mechanical deformations of the turbine system, taking into account the rotor, shroud, and blade tip components. Validation of the tip clearance model shows that the results are realistic and reflect values found in literature. In addition, this model has been integrated with a gas turbine engine simulation, creating a platform to explore engine performance as tip clearance is adjusted. Results from the integrated model explore the effects of tip clearance on engine operation and highlight advantages of tip clearance management.

  16. 76 FR 59185 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-23

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Notice of Landing... information collection. FAA Form 7480-1 (Notice of Landing Area Proposal) is used to collect information about.... Title: Notice of Landing Area Proposal. Form Numbers: FAA Form 7480-1. Type of Review: Renewal of an...

  17. 77 FR 71473 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-30

    ... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Notice of Landing... information collection. FAA Form 7480-1 (Notice of Landing Area Proposal) is used to collect information about.... Title: Notice of Landing Area Proposal. Form Numbers: FAA Form 7480-1. Type of Review: Renewal of an...

  18. Impairment of Release Site Clearance within the Active Zone by Reduced SCAMP5 Expression Causes Short-Term Depression of Synaptic Release.

    PubMed

    Park, Daehun; Lee, Unghwi; Cho, Eunji; Zhao, Haiyan; Kim, Jung Ah; Lee, Byoung Ju; Regan, Philip; Ho, Won-Kyung; Cho, Kwangwook; Chang, Sunghoe

    2018-03-20

    Despite being a highly enriched synaptic vesicle (SV) protein and a candidate gene for autism, the physiological function of SCAMP5 remains mostly enigmatic. Here, using optical imaging and electrophysiological experiments, we demonstrate that SCAMP5 plays a critical role in release site clearance at the active zone. Truncation analysis revealed that the 2/3 loop domain of SCAMP5 directly interacts with adaptor protein 2, and this interaction is critical for its role in release site clearance. Knockdown (KD) of SCAMP5 exhibited pronounced synaptic depression accompanied by a slower recovery of the SV pool. Moreover, it induced a strong frequency-dependent short-term depression of synaptic release, even under the condition of sufficient release-ready SVs. Super-resolution microscopy further proved the defects in SV protein clearance induced by KD. Thus, reduced expression of SCAMP5 may impair the efficiency of SV clearance at the active zone, and this might relate to the synaptic dysfunction observed in autism. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  19. Constitutive androstane receptor activation promotes bilirubin clearance in a murine model of alcoholic liver disease.

    PubMed

    Wang, Xiuyan; Zheng, Liyu; Wu, Jinming; Tang, Binbin; Zhang, Mengqin; Zhu, Debin; Lin, Xianfan

    2017-06-01

    Increased plasma levels of bilirubin have been reported in rat models and patients with alcoholic liver disease (ALD). The constitutive androstane receptor (CAR) is a known xenobiotic receptor, which induces the detoxification and transport of bilirubin. In the present study, the bilirubin transport regulatory mechanisms, and the role of CAR activation in hepatic and extrahepatic bilirubin clearance were investigated in a murine model of ALD. The mice were fed a Lieber-DeCarli ethanol diet or an isocaloric control diet for 4 weeks, followed by the administration of CAR agonists, 1,4-bis-[2‑(3,5-dichlorpyridyloxy)]benzene (TCPOBOP) and phenobarbital (PB), and their vehicles to examine the effect of the pharmacological activation of CAR on serum levels of bilirubin and on the bilirubin clearance pathway in ALD by serological survey, western blotting and reverse transcription‑quantitative polymerase chain reaction. The results showed that chronic ethanol ingestion impaired the nuclear translocation of CAR, which was accompanied by elevated serum levels of bilirubin, suppression of the expression of hepatic and renal organic anion transporting polypeptide (OATP) 1A1 and hepatic multidrug resistance‑associated protein 2 (MRP2), and induction of the expression of UDP-glucuronosyltransferase (UGT) 1A1. The activation of CAR by TCPOBOP and PB resulted in downregulation of the serum levels of bilirubin followed by selective upregulation of the expression levels of OATP1A1, OATP1A4, UGT1A1 and MRP2 in ALD. These results revealed the bilirubin transport regulatory mechanisms and highlighted the importance of CAR in modulating the bilirubin clearance pathway in the ALD mouse model.

  20. Structure-activity models of oral clearance, cytotoxicity, and LD50: a screen for promising anticancer compounds

    PubMed Central

    Boik, John C; Newman, Robert A

    2008-01-01

    Background Quantitative structure-activity relationship (QSAR) models have become popular tools to help identify promising lead compounds in anticancer drug development. Few QSAR studies have investigated multitask learning, however. Multitask learning is an approach that allows distinct but related data sets to be used in training. In this paper, a suite of three QSAR models is developed to identify compounds that are likely to (a) exhibit cytotoxic behavior against cancer cells, (b) exhibit high rat LD50 values (low systemic toxicity), and (c) exhibit low to modest human oral clearance (favorable pharmacokinetic characteristics). Models were constructed using Kernel Multitask Latent Analysis (KMLA), an approach that can effectively handle a large number of correlated data features, nonlinear relationships between features and responses, and multitask learning. Multitask learning is particularly useful when the number of available training records is small relative to the number of features, as was the case with the oral clearance data. Results Multitask learning modestly but significantly improved the classification precision for the oral clearance model. For the cytotoxicity model, which was constructed using a large number of records, multitask learning did not affect precision but did reduce computation time. The models developed here were used to predict activities for 115,000 natural compounds. Hundreds of natural compounds, particularly in the anthraquinone and flavonoids groups, were predicted to be cytotoxic, have high LD50 values, and have low to moderate oral clearance. Conclusion Multitask learning can be useful in some QSAR models. A suite of QSAR models was constructed and used to screen a large drug library for compounds likely to be cytotoxic to multiple cancer cell lines in vitro, have low systemic toxicity in rats, and have favorable pharmacokinetic properties in humans. PMID:18554402

  1. Structure-activity models of oral clearance, cytotoxicity, and LD50: a screen for promising anticancer compounds.

    PubMed

    Boik, John C; Newman, Robert A

    2008-06-13

    Quantitative structure-activity relationship (QSAR) models have become popular tools to help identify promising lead compounds in anticancer drug development. Few QSAR studies have investigated multitask learning, however. Multitask learning is an approach that allows distinct but related data sets to be used in training. In this paper, a suite of three QSAR models is developed to identify compounds that are likely to (a) exhibit cytotoxic behavior against cancer cells, (b) exhibit high rat LD50 values (low systemic toxicity), and (c) exhibit low to modest human oral clearance (favorable pharmacokinetic characteristics). Models were constructed using Kernel Multitask Latent Analysis (KMLA), an approach that can effectively handle a large number of correlated data features, nonlinear relationships between features and responses, and multitask learning. Multitask learning is particularly useful when the number of available training records is small relative to the number of features, as was the case with the oral clearance data. Multitask learning modestly but significantly improved the classification precision for the oral clearance model. For the cytotoxicity model, which was constructed using a large number of records, multitask learning did not affect precision but did reduce computation time. The models developed here were used to predict activities for 115,000 natural compounds. Hundreds of natural compounds, particularly in the anthraquinone and flavonoids groups, were predicted to be cytotoxic, have high LD50 values, and have low to moderate oral clearance. Multitask learning can be useful in some QSAR models. A suite of QSAR models was constructed and used to screen a large drug library for compounds likely to be cytotoxic to multiple cancer cell lines in vitro, have low systemic toxicity in rats, and have favorable pharmacokinetic properties in humans.

  2. ADAPTIVE CLEARANCE CONTROL SYSTEMS FOR TURBINE ENGINES

    NASA Technical Reports Server (NTRS)

    Blackwell, Keith M.

    2004-01-01

    The Controls and Dynamics Technology Branch at NASA Glenn Research Center primarily deals in developing controls, dynamic models, and health management technologies for air and space propulsion systems. During the summer of 2004 I was granted the privilege of working alongside professionals who were developing an active clearance control system for commercial jet engines. Clearance, the gap between the turbine blade tip and the encompassing shroud, increases as a result of wear mechanisms and rubbing of the turbine blades on shroud. Increases in clearance cause larger specific fuel consumption (SFC) and loss of efficient air flow. This occurs because, as clearances increase, the engine must run hotter and bum more fuel to achieve the same thrust. In order to maintain efficiency, reduce fuel bum, and reduce exhaust gas temperature (EGT), the clearance must be accurately controlled to gap sizes no greater than a few hundredths of an inch. To address this problem, NASA Glenn researchers have developed a basic control system with actuators and sensors on each section of the shroud. Instead of having a large uniform metal casing, there would be sections of the shroud with individual sensors attached internally that would move slightly to reform and maintain clearance. The proposed method would ultimately save the airline industry millions of dollars.

  3. 77 FR 37706 - Agency Information Collection Activities: 30-Day Notice of Intention To Request Clearance of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-22

    ... purchase price is attributable either directly or indirectly to such assets, the transaction may not be... DEPARTMENT OF THE INTERIOR National Park Service [NPS-BSD-CONC-10370; 2410-OYC] Agency Information Collection Activities: 30-Day Notice of Intention To Request Clearance of Collection of Information...

  4. The CF6 Jet Engine Performance Improvement - Low Pressure Turbine Active Clearance Control

    NASA Technical Reports Server (NTRS)

    Beck, B. D.; Fasching, W. A.

    1982-01-01

    A low pressure turbine (LPT) active clearance control (ACC) cooling system was developed to reduce the fuel consumption of current CF6-50 turbofan engines for wide bodied commercial aircraft. The program performance improvement goal of 0.3% delta sfc was determined to be achievable with an improved impingement cooling system. The technology enables the design of an optimized manifold and piping system which is capable of a performance gain of 0.45% delta sfc.

  5. A model of clearance rate regulation in mussels

    NASA Astrophysics Data System (ADS)

    Fréchette, Marcel

    2012-10-01

    Clearance rate regulation has been modelled as an instantaneous response to food availability, independent of the internal state of the animals. This view is incompatible with latent effects during ontogeny and phenotypic flexibility in clearance rate. Internal-state regulation of clearance rate is required to account for these patterns. Here I develop a model of internal-state based regulation of clearance rate. External factors such as suspended sediments are included in the model. To assess the relative merits of instantaneous regulation and internal-state regulation, I modelled blue mussel clearance rate and growth using a DEB model. In the usual standard feeding module, feeding is governed by a Holling's Type II response to food concentration. In the internal-state feeding module, gill ciliary activity and thus clearance rate are driven by internal reserve level. Factors such as suspended sediments were not included in the simulations. The two feeding modules were compared on the basis of their ability to capture the impact of latent effects, of environmental heterogeneity in food abundance and of physiological flexibility on clearance rate and individual growth. The Holling feeding module was unable to capture the effect of any of these sources of variability. In contrast, the internal-state feeding module did so without any modification or ad hoc calibration. Latent effects, however, appeared transient. With simple annual variability in temperature and food concentration, the relationship between clearance rate and food availability predicted by the internal-state feeding module was quite similar to that observed in Norwegian fjords. I conclude that in contrast with the usual Holling feeding module, internal-state regulation of clearance rate is consistent with well-documented growth and clearance rate patterns.

  6. High Temperature Investigations into an Active Turbine Blade Tip Clearance Control Concept

    NASA Technical Reports Server (NTRS)

    Taylor, Shawn; Steinetz, Bruce M.; Oswald, Jay J.

    2007-01-01

    System studies have shown the benefits of reducing blade tip clearances in modern turbine engines. Minimizing blade tip clearances throughout the engine will contribute materially to meeting NASA s Ultra-Efficient Engine Technology (UEET) turbine engine project goals. NASA GRC is examining two candidate approaches including rub-avoidance and regeneration which are explained in subsequent slides.

  7. High Temperature Investigations into an Active Turbine Blade Tip Clearance Control Concept

    NASA Technical Reports Server (NTRS)

    Taylor, Shawn C.; Steinetz, Bruce; Oswald, Jay J.

    2008-01-01

    System studies have shown the benefits of reducing blade tip clearances in modern turbine engines. Minimizing blade tip clearances throughout the engine will contribute materially to meeting NASA s Ultra-Efficient Engine Technology (UEET) turbine engine project goals. NASA GRC is examining two candidate approaches including rub-avoidance and regeneration which are explained in subsequent slides.

  8. Predicting Human Clearance of OATP substrates using Cynomolgus monkey: In vitro-in vivo scaling of hepatic uptake clearance.

    PubMed

    de Bruyn, Tom; Ufuk, Ayse; Cantrill, Carina; Kosa, Rachel E; Bi, Yi-An; Niosi, Mark; Modi, Sweta; Rodrigues, A David; Tremaine, Larry M; Varma, Manthena Vs; Galetin, Aleksandra; Houston, J Brian

    2018-05-02

    This work explores the utility of the cynomolgus monkey as a preclinical model to predict hepatic uptake clearance mediated by organic anion transporting polypeptide (OATP) transporters. Nine OATP substrates (rosuvastatin, pravastatin, repaglinide, fexofenadine, cerivastatin, telmisartan, pitavastatin, bosentan and valsartan) were investigated in plated cynomolgus monkey and human hepatocytes. Total uptake clearance and passive diffusion were measured in vitro from initial rates in the absence and presence of the OATP inhibitor rifamycin SV, respectively. Total uptake clearance values in plated hepatocytes ranged over three orders of magnitude in both species with a similar rank order and good agreement in the relative contribution of active transport to total uptake between cynomolgus monkey and human. In vivo hepatic clearance for these nine drugs was determined in cynomolgus monkey after intravenous dosing. Hepatic clearances showed a similar range to human parameters and good predictions from respective hepatocyte parameters (with 2.7 and 3.8-fold bias on average, respectively). The use of cross species empirical scaling factors (based on either dataset average or individual drug scaling factor from cynomolgus monkey data) improved prediction (less bias, better concordance) of human hepatic clearance from human hepatocyte data alone. In vitro intracellular binding in hepatocytes also correlated well between species. It is concluded that the minimal species differences observed for the current dataset between cynomolgus monkey and human hepatocyte uptake, both in vitro and in vivo, support future use of this preclinical model to delineate drug hepatic uptake and enable prediction of human in vivo intrinsic hepatic clearance. The American Society for Pharmacology and Experimental Therapeutics.

  9. 76 FR 35069 - Agency Information Collection Activities; Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-15

    ... precision requirements or power calculations that justify the proposed sample size, the expected response...; Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...

  10. 78 FR 74175 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-10

    ... precision requirements or power calculations that justify the proposed sample size, the expected response...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  11. 76 FR 24920 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-03

    ... precision requirements or power calculations that justify the proposed sample size, the expected response... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  12. 77 FR 52708 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-30

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Information Collection request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  13. 76 FR 22937 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-25

    ...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for approval under the... INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...

  14. 76 FR 25693 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-05

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  15. 76 FR 13338 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-11

    ... Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Administrative Conference of the United... Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service.... SUPPLEMENTARY INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service...

  16. 76 FR 17861 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-31

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  17. 76 FR 19826 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-08

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential... Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY... (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...

  18. 76 FR 40981 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-12

    ...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Qualitative Feedback on Agency Service Delivery '' to OMB for approval under the Paperwork Reduction Act (PRA... 20590. SUPPLEMENTARY INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on...

  19. 75 FR 80542 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-22

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  20. 76 FR 70460 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-14

    ... of Qualitative Feedback on Agency Service Delivery ACTION: 30-Day notice of submission of information... Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service... INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...

  1. 76 FR 14948 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-18

    ...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Qualitative Feedback on Agency Service Delivery'' to OMB for approval under the Paperwork Reduction Act (PRA... the CPSC Docket No. CPSC [ ] and the title ``Generic Clearance for the Collection of Qualitative...

  2. 78 FR 26087 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-03

    ...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for approval under the.... SUPPLEMENTARY INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service...

  3. 76 FR 15027 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-18

    ... clustering), the precision requirements or power calculations that justify the proposed sample size, the...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under...

  4. 76 FR 20967 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-14

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: U... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under...

  5. Site clearance working group

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The Gulf of Mexico and Louisiana continue to be areas with a high level of facility removal, and the pace of removal is projected to increase. Regulations were promulgated for the Gulf of Mexico and Louisiana requiring that abandoned sites be cleared of debris that could interfere with fishing and shrimping activities. The site clearance regulations also required verification that the sites were clear. Additionally, government programs were established to compensate fishermen for losses associated with snagging their equipment on oil and gas related objects that remained on the water bottoms in areas other than active producing sites and sitesmore » that had been verified as clear of obstructions and snags. The oil and gas industry funds the compensation programs. This paper reviews the regulations and evolving operating practices in the Gulf of Mexico and Louisiana where site clearance and fisherman`s gear compensation regulations have been in place for a number of years. Although regulations and guidelines may be in place elsewhere in the world, this paper focuses on the Gulf of Mexico and Louisiana. Workshop participants are encouraged to bring up international issues during the course of the workshop. Additionally, this paper raises questions and focuses on issues that are of concern to the various Gulf of Mexico and Louisiana water surface and water bottom stakeholders. This paper does not have answers to the questions or issues. During the workshop participants will debate the questions and issues in an attempt to develop consensus opinions and/or make suggestions that can be provided to the appropriate organizations, both private and government, for possible future research or policy adjustments. Site clearance and facility removal are different activities. Facility removal deals with removal of the structures used to produce oil and gas including platforms, wells, casing, piles, pipelines, well protection structures, etc.« less

  6. 20 CFR 655.150 - Interstate clearance of job order.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Interstate clearance of job order. 655.150... job order. (a) SWA posts in interstate clearance system. The SWA must promptly place the job order in... transmit a copy of its active job order to all States listed in the job order as anticipated worksites...

  7. 20 CFR 655.150 - Interstate clearance of job order.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 20 Employees' Benefits 3 2013-04-01 2013-04-01 false Interstate clearance of job order. 655.150... job order. (a) SWA posts in interstate clearance system. The SWA must promptly place the job order in... transmit a copy of its active job order to all States listed in the job order as anticipated worksites...

  8. 20 CFR 655.150 - Interstate clearance of job order.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 3 2011-04-01 2011-04-01 false Interstate clearance of job order. 655.150... job order. (a) SWA posts in interstate clearance system. The SWA must promptly place the job order in... transmit a copy of its active job order to all States listed in the job order as anticipated worksites...

  9. 20 CFR 655.150 - Interstate clearance of job order.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 20 Employees' Benefits 3 2012-04-01 2012-04-01 false Interstate clearance of job order. 655.150... job order. (a) SWA posts in interstate clearance system. The SWA must promptly place the job order in... transmit a copy of its active job order to all States listed in the job order as anticipated worksites...

  10. 20 CFR 655.150 - Interstate clearance of job order.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 20 Employees' Benefits 3 2014-04-01 2014-04-01 false Interstate clearance of job order. 655.150... job order. (a) SWA posts in interstate clearance system. The SWA must promptly place the job order in... transmit a copy of its active job order to all States listed in the job order as anticipated worksites...

  11. Analysis of foot clearance in firefighters during ascent and descent of stairs.

    PubMed

    Kesler, Richard M; Horn, Gavin P; Rosengren, Karl S; Hsiao-Wecksler, Elizabeth T

    2016-01-01

    Slips, trips, and falls are a leading cause of injury to firefighters with many injuries occurring while traversing stairs, possibly exaggerated by acute fatigue from firefighting activities and/or asymmetric load carriage. This study examined the effects that fatigue, induced by simulated firefighting activities, and hose load carriage have on foot clearance while traversing stairs. Landing and passing foot clearances for each stair during ascent and descent of a short staircase were investigated. Clearances decreased significantly (p < 0.05) post-exercise for nine of 12 ascent parameters and increased for two of eight descent parameters. Load carriage resulted in significantly decreased (p < 0.05) clearance over three ascent parameters, and one increase during descent. Decreased clearances during ascent caused by fatigue or load carriage may result in an increased trip risk. Increased clearances during descent may suggest use of a compensation strategy to ensure stair clearance or an increased risk of over-stepping during descent. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  12. 77 FR 32144 - Agency Information Collection Activities: Comment Request; Generic Survey Clearance for the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-31

    ... Survey Clearance for the Directorate of Education and Human Resources (EHR) AGENCY: National Science.... The scope of the EHR Generic Clearance primarily covers descriptive information gathered from... evaluations of individual programs. The collections generally include three categories of descriptive data: (1...

  13. Effect of clearance on cartilage tribology in hip hemi-arthroplasty.

    PubMed

    Lizhang, Jia; Taylor, Simon D; Jin, Zhongmin; Fisher, John; Williams, Sophie

    2013-12-01

    Hemi-arthroplasty of the hip (an artificial femoral head articulating against the natural acetabulum) is used to treat fractured necks of femur; however, there is evidence that articulation causes erosion of the cartilage, resulting in pain for the patient. Parameters that may influence this cartilage erosion include head material and roughness, clearance between the head and acetabulum and activity levels of the patient. This study has assessed the effect of clearance of hemi-arthroplasty articulations on the contact stress, friction and cartilage deformation in an in vitro tribological simulation of the hemi-arthroplasty joint that applied dynamic loads and motion. It has been demonstrated that peak contact stress increased from 5.6 to 10.6 MPa as radial clearance increased from small (<0.6 mm) to extra-large (>1.8 mm). In all samples, friction factor increased with time and was significantly less with extra-large clearances compared to small (<0.6 mm), medium (0.6-1.2 mm) and large (1.2-1.8 mm) clearances. The cartilage deformation observed was significantly greater in acetabulum samples paired to give small or extra-large clearances compared to those with medium or large clearances.

  14. 76 FR 13020 - Agency Information Collection Activities: Comment Request; Generic Clearance for the Collection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-09

    ... precision requirements or power calculations that justify the proposed sample size, the expected response... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Department of... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  15. Lactate Clearance and Normalization and Prolonged Organ Dysfunction in Pediatric Sepsis.

    PubMed

    Scott, Halden F; Brou, Lina; Deakyne, Sara J; Fairclough, Diane L; Kempe, Allison; Bajaj, Lalit

    2016-03-01

    To evaluate whether lactate clearance and normalization during emergency care of pediatric sepsis is associated with lower rates of persistent organ dysfunction. This was a prospective cohort study of 77 children <18 years of age in the emergency department with infection and acute organ dysfunction per consensus definitions. In consented patients, lactate was measured 2 and/or 4 hours after an initial lactate; persistent organ dysfunction was assessed through laboratory and physician evaluation at 48 hours. A decrease of ≥ 10% from initial to final level was considered lactate clearance; a final level < 2 mmol/L was considered lactate normalization. Relative risk (RR) with 95% CIs, adjusted in a log-binomial model, was used to evaluate associations between lactate clearance/normalization and organ dysfunction. Lactate normalized in 62 (81%) patients and cleared in 70 (91%). The primary outcome, persistent 48-hour organ dysfunction, was present in 32 (42%). Lactate normalization was associated with decreased risk of persistent organ dysfunction (RR 0.46, 0.29-0.73; adjusted RR 0.47, 0.29-0.78); lactate clearance was not (RR 0.70, 0.35-1.41; adjusted RR 0.75, 0.38-1.50). The association between lactate normalization and decreased risk of persistent organ dysfunction was retained in the subgroups with initial lactate ≥ 2 mmol/L and hypotension. In children with sepsis and organ dysfunction, lactate normalization within 4 hours was associated with decreased persistent organ dysfunction. Serial lactate level measurement may provide a useful prognostic tool during the first hours of resuscitation in pediatric sepsis. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Repeated swim impairs serotonin clearance via a corticosterone-sensitive mechanism: organic cation transporter 3, the smoking gun.

    PubMed

    Baganz, Nicole; Horton, Rebecca; Martin, Kathryn; Holmes, Andrew; Daws, Lynette C

    2010-11-10

    Activation of the hypothalamic-pituitary-adrenal (HPA) axis is associated with increased extracellular serotonin (5-HT) in limbic brain regions. The mechanism through which this occurs remains unclear. One way could be via HPA axis-dependent impairment of serotonin transporter (SERT) function, the high-affinity uptake mechanism for 5-HT. Consistent with this idea, we found that 5-HT clearance rate in hippocampus was dramatically reduced in mice exposed to repeated swim, a stimulus known to activate the HPA axis. However, this phenomenon also occurred in mice lacking SERT, ruling out SERT as a mechanism. The organic cation transporter 3 (OCT3) is emerging as an important regulator of brain 5-HT. Moreover, corticosterone, which is released upon HPA axis activation, blocks 5-HT uptake by OCT3. Repeated swim produced a persistent elevation in plasma corticosterone, and, consistent with prolonged blockade by corticosterone, we found that OCT3 expression and function were reduced in these mice. Importantly, this effect of repeated swim to reduce 5-HT clearance rate was corticosterone dependent, as evidenced by its absence in adrenalectomized mice, in which plasma corticosterone levels were essentially undetectable. Behaviorally, mice subjected to repeated swim spent less time immobile in the tail suspension test than control mice, but responded similarly to SERT- and norepinephrine transporter-selective antidepressants. Together, these results show that reduced 5-HT clearance following HPA axis activation is likely mediated, at least in part, by the corticosterone-sensitive OCT3, and that drugs developed to selectively target OCT3 (unlike corticosterone) may be candidates for the development of novel antidepressant medications.

  17. 76 FR 13019 - Agency Information Collection Activities: Comment Request; Generic Clearance for the Collection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-09

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Department of...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...

  18. Daily heat stress treatment rescues denervation-activated mitochondrial clearance and atrophy in skeletal muscle

    PubMed Central

    Tamura, Yuki; Kitaoka, Yu; Matsunaga, Yutaka; Hoshino, Daisuke; Hatta, Hideo

    2015-01-01

    Traumatic nerve injury or motor neuron disease leads to denervation and severe muscle atrophy. Recent evidence indicates that loss of mitochondria and the related reduction in oxidative capacity could be key mediators of skeletal muscle atrophy. As our previous study showed that heat stress increased the numbers of mitochondria in skeletal muscle, we evaluated whether heat stress treatment could have a beneficial impact on denervation-induced loss of mitochondria and subsequent muscle atrophy. Here, we report that daily heat stress treatment (mice placed in a chamber with a hot environment; 40°C, 30 min day−1, for 7 days) rescues the following parameters: (i) muscle atrophy (decreased gastrocnemius muscle mass); (ii) loss of mitochondrial content (decreased levels of ubiquinol–cytochrome c reductase core protein II, cytochrome c oxidase subunits I and IV and voltage-dependent anion channel protein); and (iii) reduction in oxidative capacity (reduced maximal activities of citrate synthase and 3-hydroxyacyl-CoA dehydrogenase) in denervated muscle (produced by unilateral sciatic nerve transection). In order to gain a better understanding of the above mitochondrial adaptations, we also examined the effects of heat stress on autophagy-dependent mitochondrial clearance (mitophagy). Daily heat stress normalized denervation-activated induction of mitophagy (increased mitochondrial microtubule-associated protein 1A/1B-light chain3-II (LC3-II) with and without blocker of autophagosome clearance). The molecular basis of this observation was explained by the results that heat stress attenuated the denervation-induced increase in key proteins that regulate the following steps: (i) the tagging step of mitochondrial clearance (increased mitochondrial Parkin, ubiquitin-conjugated, P62/sequestosome 1 (P62/SQSTM1)); and (ii) the elongation step of autophagosome formation (increased Atg5–Atg12 conjugate and Atg16L). Overall, our results contribute to the better

  19. THE INFLUENCE OF SERUM BINDING PROTEINS AND CLEARANCE ON THE COMPARATIVE RECEPTOR BINDING POTENCY OF ENDOCRINE ACTIVE COMPOUNDS

    EPA Science Inventory

    THE INFLUENCE OF SERUM BINDING PROTEINS AND CLEARANCE ON THE COMPARATIVE RECEPTOR BINDING POTENCY OF ENDOCRINE ACTIVE COMPOUNDS. JG Teeguarden1 and HA Barton2. 1ENVIRON International, Ruston LA; 2US EPA, ORD, NHEERL, ETD, Pharmacokinetics Branch, RTP, NC.

    One measure of th...

  20. [Correlation index amylase-creatinine clearance to endogenous creatinine clearance in severe preeclampsia].

    PubMed

    Vázquez Rodríguez, Juan Gustavo; Cruz Cruz, Polita del Rocío; Márquez Hubert, Elizabeth

    2009-07-01

    Tubular lesion may cause acute renal insufficiency in pregnant patients with severe preeclampsia. To describe the correlation between the amylase/creatinine clearance ratio and endogenous creatinine depuration in pregnant patients with severe preeclampsia. Transversal study (pilot study) twenty eight women with pregnancies of 20 to 40 weeks complicated by severe preeclampsia were studied. Subjects had serum and urine creatinine and amylase determinations to calculate the amylase/creatinine clearance ratio (%). According to the results, two groups were formed: group A (> 3%) and group B (< or = 3%). The correlation between amylase/creatinine clearance ratio and endogenous creatinine depuration was evaluated. measures of central tendency and dispersion, Student's t-test, Pearson correlation coefficient (r) and linear regression were used. Group A included 23 cases (82%) and group B included 5 cases (18%). Amylase/creatinine clearance ratio (%) for group A was 5.22 +/- 1.6 and for group B was 2.41 +/- 0.41 (p = 0.001). The endogenous creatinine depuration (mL /min. /1.73 m2 SC) for group A was 105.6 +/- 9.71 and for group B was 132.10 +/- 7.95 (p = 0.54). The r between amylase/creatinine clearance ratio and endogenous creatinine depuration for group A was -0.43 and for group B was -0.25. A moderately significant negative correlation exists between amylase/creatinine clearance ratio and endogenous creatinine depuration.

  1. 14 CFR 25.925 - Propeller clearance.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Propeller clearance. 25.925 Section 25.925... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant General § 25.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances with the airplane at maximum weight, with the most adverse...

  2. 14 CFR 23.925 - Propeller clearance.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Propeller clearance. 23.925 Section 23.925... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant General § 23.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances, with the airplane at the most...

  3. 14 CFR 23.925 - Propeller clearance.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Propeller clearance. 23.925 Section 23.925... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant General § 23.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances, with the airplane at the most...

  4. 14 CFR 23.925 - Propeller clearance.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Propeller clearance. 23.925 Section 23.925... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant General § 23.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances, with the airplane at the most...

  5. 14 CFR 25.925 - Propeller clearance.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Propeller clearance. 25.925 Section 25.925... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant General § 25.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances with the airplane at maximum weight, with the most adverse...

  6. 14 CFR 25.925 - Propeller clearance.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Propeller clearance. 25.925 Section 25.925... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant General § 25.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances with the airplane at maximum weight, with the most adverse...

  7. 14 CFR 25.925 - Propeller clearance.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Propeller clearance. 25.925 Section 25.925... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant General § 25.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances with the airplane at maximum weight, with the most adverse...

  8. 14 CFR 23.925 - Propeller clearance.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Propeller clearance. 23.925 Section 23.925... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant General § 23.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances, with the airplane at the most...

  9. 77 FR 43373 - Emergency Clearance; Public Information Collection Requirements Submitted to the Office of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-24

    ... postsecondary students in basic and applied research in STEM. If NSF must follow the normal OIRA clearance... request will assure continuation of the collection of information on student participants in the Research... undergraduate research experiences, NSF will have no other means to consistently document the number and...

  10. Applying Organ Clearance Concepts in a Clinical Setting

    PubMed Central

    2008-01-01

    Objective To teach doctor of pharmacy (PharmD) students how to apply organ clearance concepts in a clinical setting in order to optimize dose management, select the right drug product, and promote better patient-centered care practices. Design A student-focused 5-hour topic entitled "Organ Clearance Concepts: Modeling and Clinical Applications" was developed and delivered to second-year PharmD students. Active-learning techniques, such as reading assignments and thought-provoking questions, and collaborative learning techniques, such as small groups, were used. Student learning was assessed using application cards and a minute paper. Assessment Overall student responses to topic presentation were overwhelmingly positive. The teaching strategies here discussed allowed students to play an active role in their own learning process and provided the necessary connection to keep them motivated, as mentioned in the application cards and minute paper assessments. Students scored an average of 88% on the examination given at the end of the course. Conclusion By incorporating active-learning and collaborative-learning techniques in presenting material on organ clearance concept, students gained a more thorough knowledge of dose management and drug-drug interactions than if the concepts had been presented using a traditional lecture format. This knowledge will help students in solving critical patient situations in a real-world context. PMID:19214275

  11. Online monitoring of dynamic tip clearance of turbine blades in high temperature environments

    NASA Astrophysics Data System (ADS)

    Han, Yu; Zhong, Chong; Zhu, Xiaoliang; Zhe, Jiang

    2018-04-01

    Minimized tip clearance reduces the gas leakage over turbine blade tips and improves the thrust and efficiency of turbomachinery. An accurate tip clearance sensor, measuring the dynamic clearances between blade tips and the turbine case, is a critical component for tip clearance control. This paper presents a robust inductive tip clearance sensor capable of monitoring dynamic tip clearances of turbine machines in high-temperature environments and at high rotational speeds. The sensor can also self-sense the temperature at a blade tip in situ such that temperature effect on tip clearance measurement can be estimated and compensated. To evaluate the sensor’s performance, the sensor was tested for measuring the tip clearances of turbine blades under various working temperatures ranging from 700 K to 1300 K and at turbine rotational speeds ranging from 3000 to 10 000 rpm. The blade tip clearance was varied from 50 to 2000 µm. The experiment results proved that the sensor can accurately measure the blade tip clearances with a temporal resolution of 10 µm. The capability of accurately measuring the tip clearances at high temperatures (~1300 K) and high turbine rotation speeds (~30 000 rpm), along with its compact size, makes it promising for online monitoring and active control of blade tip clearances of high-temperature turbomachinery.

  12. 20 CFR 653.501 - Requirements for accepting and processing clearance orders.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., DEPARTMENT OF LABOR SERVICES OF THE EMPLOYMENT SERVICE SYSTEM Agricultural Clearance Order Activity § 653.501... function of the job service as a no-fee labor exchange, that is, as a forum for bringing together employers... referred through the clearance system shall be notified to contact a local job service office, preferably...

  13. 20 CFR 653.501 - Requirements for accepting and processing clearance orders.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., DEPARTMENT OF LABOR SERVICES OF THE EMPLOYMENT SERVICE SYSTEM Agricultural Clearance Order Activity § 653.501... function of the job service as a no-fee labor exchange, that is, as a forum for bringing together employers... referred through the clearance system shall be notified to contact a local job service office, preferably...

  14. Fenofibrate Decreases Insulin Clearance and Insulin Secretion to Maintain Insulin Sensitivity*

    PubMed Central

    Ramakrishnan, Sadeesh K.; Russo, Lucia; Ghanem, Simona S.; Patel, Payal R.; Oyarce, Ana Maria; Heinrich, Garrett; Najjar, Sonia M.

    2016-01-01

    High fat diet reduces the expression of CEACAM1 (carcinoembryonic antigen-related cell adhesion molecule 1), a transmembrane glycoprotein that promotes insulin clearance and down-regulates fatty acid synthase activity in the liver upon its phosphorylation by the insulin receptor. Because peroxisome proliferator-activated receptor α (PPARα) transcriptionally suppresses CEACAM1 expression, we herein examined whether high fat down-regulates CEACAM1 expression in a PPARα-dependent mechanism. By activating PPARα, the lipid-lowering drug fenofibrate reverses dyslipidemia and improves insulin sensitivity in type 2 diabetes in part by promoting fatty acid oxidation. Despite reducing glucose-stimulated insulin secretion, fenofibrate treatment does not result in insulin insufficiency. To examine whether this is mediated by a parallel decrease in CEACAM1-dependent hepatic insulin clearance pathways, we fed wild-type and Pparα−/− null mice a high fat diet supplemented with either fenofibrate or Wy14643, a selective PPARα agonist, and examined their effect on insulin metabolism and action. We demonstrated that the decrease in insulin secretion by fenofibrate and Wy14643 is accompanied by reduction in insulin clearance in wild-type but not Pparα−/− mice, thereby maintaining normoinsulinemia and insulin sensitivity despite continuous high fat intake. Intact insulin secretion in L-CC1 mice with protected hepatic insulin clearance and CEACAM1 levels provides in vivo evidence that insulin secretion responds to changes in insulin clearance to maintain physiologic insulin and glucose homeostasis. These results also emphasize the relevant role of hepatic insulin extraction in regulating insulin sensitivity. PMID:27662905

  15. Application of an in vitro OAT assay in drug design and optimization of renal clearance.

    PubMed

    Soars, Matthew G; Barton, Patrick; Elkin, Lisa L; Mosure, Kathleen W; Sproston, Joanne L; Riley, Robert J

    2014-07-01

    1. Optimization of renal clearance is a complex balance between passive and active processes mediated by renal transporters. This work aimed to characterize the interaction of a series of compounds with rat and human organic anion transporters (OATs) and develop quantitative structure-activity relationships (QSARs) to optimize renal clearance. 2. In vitro inhibition assays were established for human OAT1 and rat Oat3 and rat in vivo renal clearance was obtained. Statistically significant quantitative relationships were explored between the compounds' physical properties, their affinity for OAT1 and oat3 and the inter-relationship with unbound renal clearance (URC) in rat. 3. Many of the compounds were actively secreted and in vitro analysis demonstrated that these were ligands for rat and human OAT transporters (IC50 values ranging from <1 to >100 µM). Application of resultant QSAR models reduced renal clearance in the rat from 24 to <0.1 ml/min/kg. Data analysis indicated that the properties associated with increasing affinity at OATs are the same as those associated with reducing URC but orthogonal in nature. 4. This study has demonstrated that OAT inhibition data and QSAR models can be successfully used to optimize rat renal clearance in vivo and provide confidence of translation to humans.

  16. Thermal shielding of an emerging active region

    NASA Astrophysics Data System (ADS)

    Régnier, S.

    2012-08-01

    Context. The interaction between emerging active regions and the pre-existing coronal magnetic field is important for better understanding the mechanisms of storage and release of magnetic energy from the convection zone to the high corona. Aims: We describe the first steps of an emerging active region within a pre-existing quiet-Sun corona in terms of the thermal and magnetic structure. Methods: We used unprecedented spatial, temporal and spectral coverage from the Atmospheric Imager Assembly (AIA) and from the Helioseismic and Magnetic Imager (HMI) on board the Solar Dynamics Observatory (SDO). Results: Starting on 30 May 2010 at 17:00 UT, we followed the emerging active region AR11076 within a quiet-Sun region for 8 h. Using several SDO/AIA filters that cover temperatures from 50 000 K to 10 MK, we show that the emerging process is characterised by a thermal shield at the interface between the emerging flux and pre-existing quiet-Sun corona. Conclusions: The active region 11076 is a peculiar example of an emerging active region because (i) the polarities emerge in a photospheric quiet-Sun region near a supergranular-like distribution, and (ii) the polarities that form the bipolar emerging structure do not rotate with respect to each other, which indicates a slight twist in the emerging flux bundle. There is a thermal shield at the interface between the emerging active region and the pre-existing quiet-Sun region. The thermal shielding structure deduced from all SDO/AIA channels is strongly asymmetric between the two polarities of the active region, suggesting that the heating mechanism for one polarity is probably magnetic reconnection, whilst it is caused by increasing magnetic pressure for the opposite polarity. Appendix A and two movies are available in electronic form at http://www.aanda.org

  17. UXO clearance operation in Laos

    NASA Astrophysics Data System (ADS)

    Sato, Motoyuki; Kadoya, Yoshihiko

    2018-04-01

    Laos is one of the most seriously contaminated countries by UXO. Most of the UXO are cluster bombs, used in 1960- 70's. There is historical political background about the UXO problems in Laos. Currently, The clearance of UXO is significantly important for future economic development for Laos. It affects not only local inhabitants, but it will affects national economy. For example, UXO clearance in mountainous area can promote construction of roads, and Laos has a good possibility to be the center of transportation in Indo-Chia region. We have started a research project for evaluation of impact of UXO clearance in Laos, "The economic impact and the technological development for the elimination of unexploded ordnance (UXO) elimination in Laos". Lao National Unexploded Ordnance Programme (UXO Lao) is working in the nine most impacted provinces nationwide and it clears land for agriculture and community purposes. We recently visited Laos and observed the UXO clearance procedure conducted by UXOLAO. The technical survey for UXO clearance site to determine for operation, UXO detection by using metal detectors are organized by UXO Lao. In this paper, we will report the technical aspects of the UXO clearance in Laos.

  18. Increased Glyburide Clearance in the Pregnant Mouse Model

    PubMed Central

    Zhou, Lin; Zhang, Yi; Hebert, Mary F.; Unadkat, Jashvant D.

    2010-01-01

    Glyburide (GLB) is an oral sulfonylurea, commonly used for the treatment of gestational diabetes mellitus. It has been reported that the clearance of GLB in pregnant women is significantly higher than that in nonpregnant women. The molecular mechanism by which pregnancy increases the clearance of GLB is not known, but it may be caused by increased CYP3A activity. Because liver tissue from pregnant women is not readily available, in the present study, we investigated the mechanism of such pregnancy-related changes in GLB disposition in a mouse model. We demonstrated that the systemic clearance of GLB in pregnant mice was increased approximately 2-fold (p < 0.01) compared with nonpregnant mice, a magnitude of change similar to that observed in the clinical study. Plasma protein binding of GLB in mice was not altered by pregnancy. The half-life of GLB depletion in hepatic S-9 fractions of pregnant mice was significantly shorter than that of nonpregnant mice. Moreover, GLB depletion was markedly inhibited by ketoconazole, a potent inhibitor of mouse Cyp3a, suggesting that GLB metabolism in mice is primarily mediated by hepatic Cyp3a. These data suggest that the increased systemic clearance of GLB in pregnant mice is likely caused by an increase in hepatic Cyp3a activity during pregnancy, and they provide a basis for further mechanistic understanding and analysis of pregnancy-induced alterations in the disposition of GLB and drugs that are predominantly and extensively metabolized by CYP3A/Cyp3a. PMID:20558597

  19. Active Chest Tube Clearance After Cardiac Surgery Is Associated With Reduced Reexploration Rates.

    PubMed

    Grieshaber, Philippe; Heim, Nicolas; Herzberg, Moritz; Niemann, Bernd; Roth, Peter; Boening, Andreas

    2018-06-01

    Ineffective evacuation of intrathoracic fluid after cardiac surgery (retained blood syndrome [RBS]) might increase postoperative complications, morbidity, and mortality. Active tube clearance (ATC) technology using an intraluminal clearing apparatus aims at increasing chest tube drainage efficiency. This study evaluated whether ATC reduces RBS in an all-comers collective undergoing scheduled cardiac surgery with cardiopulmonary bypass and full or partial median sternotomy. In this nonrandomized prospective trial, 581 consecutive patients undergoing scheduled cardiac surgery with median sternotomy between January 2016 and December 2016 were assigned to receive conventional chest tubes (control group) or a combination of conventional tubes and as many as two ATC devices (ATC group), depending on their operation date. Postoperative occurrence of RBS (one or more of the following: reexploration for bleeding or tamponade, pericardial drainage procedure, pleural drainage procedure) and other endpoints were compared. Propensity score matching was applied. In 222 ATC patients and 222 matched control patients, RBS occurrence did not differ between the groups (ATC 16%, control 22%; p = 0.15). However, reexploration rate for bleeding or tamponade was significantly reduced in the ATC group compared with the control group (4.1% versus 9.1%, respectively; p = 0.015). The mortality of RBS patients (21%) was higher compared with patients without RBS (3.9%, p < 0.001). Among the RBS components, only reexploration (odds ratio 16, 95% confidence interval: 5.8 to 43, p < 0.001) was relevant for inhospital mortality (ATC 6.8%, control 7.7%; p = 0.71). Active tube clearance is associated with reduced reexploration rates in an all-comers collective undergoing cardiac surgery. Reexploration is the only RBS component relevant for mortality. The ATC effect does not translate into improved overall survival. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All

  20. 30 CFR 18.24 - Electrical clearances.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Electrical clearances. 18.24 Section 18.24... APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical conductor...

  1. 30 CFR 18.24 - Electrical clearances.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Electrical clearances. 18.24 Section 18.24... APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical conductor...

  2. 30 CFR 18.24 - Electrical clearances.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Electrical clearances. 18.24 Section 18.24... APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical conductor...

  3. Selectively enhanced expression of prophenoloxidase activating enzyme 1 (PPAE1) at a bacteria clearance site in the white shrimp, Litopenaeus vannamei

    PubMed Central

    2011-01-01

    Background The prophenoloxidase-activating (PO activating) system plays an important role in the crustacean innate immunity, particularly in wound healing and pathogen defense. A key member of this system is prophenoloxidase-activating enzyme (PPAE), which is the direct activator of prophenoloxidase (proPO). Despite their importance in crustacean PO activating system, the studies on them remain limited. Results Here we report on a PPAE of white shrimp, Litopenaeus vannamei (lvPPAE1), which showed 94% similarity to PPAE1 of Penaeus monodon. We found that lvPPAE1 in fluid hemocytes was down regulated after challenge by Vibrio harveyi but was enhanced when shrimps were exposed to a bacteria-rich environment for long-term. In vivo gene silence of lvPPAE1 by RNAi can significantly reduce the phenoloxidase activity (PO) and increase the susceptibility of shrimps to V. harveyi. Although lvPPAE1 was down-regulated in fluid hemocytes by Vibrio challenge, its expression increased significantly in gill after bacteria injection, which is the primary bacteria-clearance tissue. Conclusion Suppressed expression in fluid hemocytes and enhanced expression in gill indicates selectively enhanced expression at the bacterial clearance site. This is a novel feature for PPAE expression. The results will contribute to our understanding of the PO activating system in crustaceans. PMID:22208405

  4. 22 CFR 16.6 - Security clearances.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 22 Foreign Relations 1 2011-04-01 2011-04-01 false Security clearances. 16.6 Section 16.6 Foreign Relations DEPARTMENT OF STATE PERSONNEL FOREIGN SERVICE GRIEVANCE SYSTEM § 16.6 Security clearances. The agencies shall use their best endeavors to expedite security clearances whenever necessary to ensure a fair...

  5. 22 CFR 16.6 - Security clearances.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 22 Foreign Relations 1 2013-04-01 2013-04-01 false Security clearances. 16.6 Section 16.6 Foreign Relations DEPARTMENT OF STATE PERSONNEL FOREIGN SERVICE GRIEVANCE SYSTEM § 16.6 Security clearances. The agencies shall use their best endeavors to expedite security clearances whenever necessary to ensure a fair...

  6. 22 CFR 16.6 - Security clearances.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Security clearances. 16.6 Section 16.6 Foreign Relations DEPARTMENT OF STATE PERSONNEL FOREIGN SERVICE GRIEVANCE SYSTEM § 16.6 Security clearances. The agencies shall use their best endeavors to expedite security clearances whenever necessary to ensure a fair...

  7. Tracking short-term biodistribution and long-term clearance of SPIO tracers in magnetic particle imaging

    NASA Astrophysics Data System (ADS)

    Keselman, Paul; Yu, Elaine Y.; Zhou, Xinyi Y.; Goodwill, Patrick W.; Chandrasekharan, Prashant; Ferguson, R. Matthew; Khandhar, Amit P.; Kemp, Scott J.; Krishnan, Kannan M.; Zheng, Bo; Conolly, Steven M.

    2017-05-01

    Magnetic particle imaging (MPI) is an emerging tracer-based medical imaging modality that images non-radioactive, kidney-safe superparamagnetic iron oxide (SPIO) tracers. MPI offers quantitative, high-contrast and high-SNR images, so MPI has exceptional promise for applications such as cell tracking, angiography, brain perfusion, cancer detection, traumatic brain injury and pulmonary imaging. In assessing MPI’s utility for applications mentioned above, it is important to be able to assess tracer short-term biodistribution as well as long-term clearance from the body. Here, we describe the biodistribution and clearance for two commonly used tracers in MPI: Ferucarbotran (Meito Sangyo Co., Japan) and LS-oo8 (LodeSpin Labs, Seattle, WA). We successfully demonstrate that 3D MPI is able to quantitatively assess short-term biodistribution, as well as long-term tracking and clearance of these tracers in vivo.

  8. Impact of fraction unbound, CYP3A, and CYP2D6 in vivo activities, and other potential covariates to the clearance of tramadol enantiomers in patients with neuropathic pain.

    PubMed

    de Moraes, Natália V; Lauretti, Gabriela R; Coelho, Eduardo B; Godoy, Ana Leonor P C; Neves, Daniel V; Lanchote, Vera L

    2016-04-01

    The pharmacokinetics of tramadol is characterized by a large interindividual variability, which is partially attributed to polymorphic CYP2D6 metabolism. The contribution of CYP3A, CYP2B6, fraction unbound, and other potential covariates remains unknown. This study aimed to investigate the contribution of in vivo activities of cytochrome P450 (CYP) 2D6 and 3A as well as other potential covariates (CYP2B6 genotype to the SNP g.15631G>T, fraction unbound, age, body weight, creatinine clearance) to the enantioselective pharmacokinetics of tramadol. Thirty patients with neuropathic pain and phenotyped as CYP2D6 extensive metabolizers were treated with a single oral dose of 100 mg tramadol. Multiple linear regressions were performed to determine the contribution of CYP activities and other potential covariates to the clearance of tramadol enantiomers. The apparent total clearances were 44.9 (19.1-102-2) L/h and 55.2 (14.8-126.0) L/h for (+)- and (-)-tramadol, respectively [data presented as median (minimum-maximum)]. Between 79 and 83% of the overall variation in apparent clearance of tramadol enantiomers was explained by fraction unbound, CYP2D6, and CYP3A in vivo activities and body weight. Fraction unbound explained 47 and 41% of the variation in clearance of (+)-tramadol and (-)-tramadol, respectively. Individually, CYP2D6 and CYP3A activities were shown to have moderate contribution on clearance of tramadol enantiomers (11-16% and 11-18%, respectively). In conclusion, factors affecting fraction unbound of drugs (such as hyperglycemia or co-administration of drugs highly bound to plasma proteins) should be monitored, because this parameter dominates the elimination of tramadol enantiomers. © 2015 Société Française de Pharmacologie et de Thérapeutique.

  9. Acute Mucociliary Clearance Response to Aerobic Exercise in Smokers.

    PubMed

    Ramos, Ercy M C; Vanderlei, Luiz Carlos M; Ito, Juliana T; Lima, Fabiano F; Rodrigues, Fernanda M M; Manzano, Beatriz M; Fernandes, Rômulo A; Cecílio, Michel J; Toledo-Arruda, Alessandra C; Ramos, Dionei

    2015-11-01

    Mucociliary clearance is the main defense mechanism of the respiratory system, and it is influenced by several stimuli, including aerobic exercise and cigarette smoking. We evaluated the acute response of mucociliary clearance to aerobic exercise in smokers and nonsmokers compared with that found after acute smoking and smoking combined with exercise. Also, we investigated whether there was a correlation between mucociliary clearance and the autonomic nervous system under these conditions. Twenty-one smokers were evaluated for mucociliary clearance by saccharin transit time (STT), and the response of the autonomic nervous system was evaluated by heart rate variability after aerobic exercise, after exercise followed by smoking, after acute smoking, and after rest. For comparison, 17 nonsmokers were also assessed during exercise. Repeated-measures analysis of variance with the Tukey test or the Friedman test followed by the Dunn test was used to evaluate the STT, autonomic response, and other variables to exercise and/or smoking in smokers. A paired t test or Wilcoxon test was used to analyze responses to exercise in nonsmokers. Correlations were evaluated using Pearson or Spearman coefficients. The STT was reduced after exercise in both groups, with similar responses between them. Other stimuli also reduced the STT. The STT showed a negative correlation with sympathetic activity in smokers and a positive correlation with the parasympathetic system in nonsmokers. Although impaired in smokers, mucociliary clearance responded to the stimulus of exercise, as demonstrated by similar STTs compared with nonsmokers. This response was correlated with the autonomic nervous system in both groups. In smokers, mucociliary clearance also responded to the stimuli of smoking and exercise followed by smoking. Copyright © 2015 by Daedalus Enterprises.

  10. Turbine blade tip clearance measurements using skewed dual optical beams of tip timing

    NASA Astrophysics Data System (ADS)

    Ye, De-chao; Duan, Fa-jie; Guo, Hao-tian; Li, Yangzong; Wang, Kai

    2011-12-01

    Optimization and active control of the clearance between turbine blades and case of the engine is identified, especially in aerospace community, as a key technology to increase engine efficiency, reduce fuel consumption and emissions and increase service life .However, the tip clearance varies during different operating conditions. Thus a reliable non-contact and online detection system is essential and ultimately used to close the tip clearance control loop. This paper described a fiber optical clearance measuring system applying skewed dual optical beams to detect the traverse time of passing blades. Two beams were specially designed with an outward angle of 18 degree and the beam spot diameters are less than 100μm within 0-4mm working range to achieve high signal-to-noise and high sensitivity. It could be theoretically analyzed that the measuring accuracy is not compromised by degradation of signal intensity caused by any number of environmental conditions such as light source instability, contamination and blade tip imperfection. Experimental tests were undertaken to achieve a high resolution of 10µm in the rotational speed range 2000-18000RPM and a measurement accuracy of 15μm, indicating that the system is capable of providing accurate and reliable data for active clearance control (ACC).

  11. No Evidence of Delayed Parasite Clearance after Oral Artesunate Treatment of Uncomplicated Falciparum Malaria in Mali

    PubMed Central

    Maiga, Amelia W.; Fofana, Bakary; Sagara, Issaka; Dembele, Demba; Dara, Antoine; Traore, Oumar Bila; Toure, Sekou; Sanogo, Kassim; Dama, Souleymane; Sidibe, Bakary; Kone, Aminatou; Thera, Mahamadou A.; Plowe, Christopher V.; Doumbo, Ogobara K.; Djimde, Abdoulaye A.

    2012-01-01

    Plasmodium falciparum resistance to artemisinins by delayed parasite clearance is present in Southeast Asia. Scant data on parasite clearance after artemisinins are available from Africa, where transmission is high, burden is greatest, and artemisinin use is being scaled up. Children 1–10 years of age with uncomplicated malaria were treated with 7 days of artesunate and followed for 28 days. Blood smears were done every 8 hours until negative by light microscopy. Results were compared with a similar study conducted in the same village in 2002–2004. The polymerase chain reaction-corrected cure rate was 100%, identical to 2002–2004. By 24 hours after treatment initiation, 37.0% of participants had cleared parasitemia, compared with 31.9% in 2002–2004 (P = 0.5). The median parasite clearance time was 32 hours. Only one participant still had parasites at 48 hours and no participant presented parasitemia at 72 hours. Artesunate was highly efficacious, with no evidence of delayed parasite clearance. We provide baseline surveillance data for the emergence or dissemination of P. falciparum resistance in sub-Saharan Africa. PMID:22764287

  12. 48 CFR 945.603-70 - Plant clearance function.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Plant clearance function... Plant clearance function. If the plant clearance function has not been formally delegated to another Federal agency, the contracting officer shall assume all responsibilities of the plant clearance officer...

  13. 48 CFR 945.603-70 - Plant clearance function.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 5 2012-10-01 2012-10-01 false Plant clearance function... Plant clearance function. If the plant clearance function has not been formally delegated to another Federal agency, the contracting officer shall assume all responsibilities of the plant clearance officer...

  14. Plasmodium falciparum malaria: Convergent evolutionary trajectories towards delayed clearance following artemisinin treatment.

    PubMed

    Wilairat, Prapon; Kümpornsin, Krittikorn; Chookajorn, Thanat

    2016-05-01

    Malaria is a major global health challenge with 300million new cases every year. The most effective regimen for treating Plasmodium falciparum malaria is based on artemisinin and its derivatives. The drugs are highly effective, resulting in rapid clearance of parasites even in severe P. falciparum malaria patients. During the last five years, artemisinin-resistant parasites have begun to emerge first in Cambodia and now in Thailand and Myanmar. At present, the level of artemisinin resistance is relatively low with clinical presentation of delayed artemisinin clearance (a longer time to reduce parasite load) and a small decrease in artemisinin sensitivity in cultured isolates. Nevertheless, multiple genetic loci associated with delayed parasite clearance have been reported, but they cannot account for a large portion of cases. Even the most well-studied kelch 13 propeller mutations cannot always predict the outcome of artemisinin treatment in vitro and in vivo. Here we propose that delayed clearance by artemisinin could be the result of convergent evolution, driven by multiple trajectories to overcome artemisinin-induced stress, but precluded to become full blown resistance by high fitness cost. Genetic association studies by several genome-wide approaches reveal linkage disequilibrium between multiple loci and delayed parasite clearance. Genetic manipulations at some of these loci already have resulted in loss in artemisinin sensitivity. The notion presented here is by itself consistent with existing evidence on artemisinin resistance and has the potential to be explored using available genomic data. Most important of all, molecular surveillance of artemisinin resistance based on multi-genic markers could be more informative than relying on any one particular molecular marker. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Hypercapnia shortens emergence time from inhaled anesthesia in pigs.

    PubMed

    Gopalakrishnan, Nishant A; Sakata, Derek J; Orr, Joseph A; McJames, Scott; Westenskow, Dwayne R

    2007-04-01

    Anesthetic clearance from the lungs and the circle rebreathing system can be maximized using hyperventilation and high fresh gas flows. However, the concomitant clearance of CO2 decreases PAco2, thereby decreasing cerebral blood flow and slowing the clearance of anesthetic from the brain. This study shows that in addition to hyperventilation, hypercapnia (CO2 infusion or rebreathing) is a significant factor in decreasing emergence time from inhaled anesthesia. We anesthetized seven pigs with 2 MACPIG of isoflurane and four with 2 MACPIG of sevoflurane. After 2 h, anesthesia was discontinued, and the animals were hyperventilated. The time to movement of multiple limbs was measured under hypocapnic (end-tidal CO2 = 22 mm Hg) and hypercapnic (end-tidal CO2 = 55 mm Hg) conditions. The time between turning off the vaporizer and to movement of multiple limbs was faster with hypercapnia during hyperventilation. Emergence time from isoflurane and sevoflurane anesthesia was shortened by an average of 65% with rebreathing or with the use of a CO2 controller (P < 0.05). Hypercapnia, along with hyperventilation, may be used clinically to decrease emergence time from inhaled anesthesia. These time savings might reduce drug costs. In addition, higher PAco2 during emergence may enhance respiratory drive and airway protection after tracheal extubation.

  16. 48 CFR 801.602-76 - Business clearance review.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Business clearance review... Authority, and Responsibilities 801.602-76 Business clearance review. (a) A business clearance review is a... obtain a business clearance review prior to award of any contract, task or delivery order, or blanket...

  17. 48 CFR 801.602-76 - Business clearance review.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Business clearance review... Authority, and Responsibilities 801.602-76 Business clearance review. (a) A business clearance review is a... obtain a business clearance review prior to award of any contract, task or delivery order, or blanket...

  18. 30 CFR 18.24 - Electrical clearances.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical conductor surfaces, or between uninsulated conductor surfaces and grounded metal surfaces, within the enclosure shall...

  19. 30 CFR 18.24 - Electrical clearances.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical conductor surfaces, or between uninsulated conductor surfaces and grounded metal surfaces, within the enclosure shall...

  20. Demographics, socio-behavioral factors, and drug use patterns: what matters in spontaneous HCV clearance?

    PubMed

    Shah, Dimpy P; Grimes, Carolyn Z; Brown, Eric; Hwang, Lu-Yu

    2012-02-01

    Hepatitis C virus (HCV), an emerging bloodborne pathogen, causes chronic liver disease frequently except in about 10-20% of infections which undergo spontaneous resolution. Investigating factors that influence viral clearance is essential to understand the natural history of this infection and establishing novel strategies for prevention and treatment. HCV clearance was estimated in a unique cohort of 1,260 HIV and HBV negative current drug users enrolled for a hepatitis B vaccination study. It was defined as the inability to detect viral RNA using a PCR method in presence of serum anti-HCV antibody EIA. Associated demographic and socio-behavioral factors including drug use patterns were identified from the enrolled subjects using multivariate regression analysis. 33.3% (420/1260) of drug users were found positive for anti-HCV antibodies and 14.8% (62/420) of these individuals achieved viral clearance (negative PCR test). Race or ethnicity of the participants was the only significant factor associated with HCV clearance. Hispanics (OR = 3.4, 95% CI: 1.3-8.5, P = 0.01) and Caucasians (OR = 3.1, 95% CI: 1.5-6.6, P = 0.003) had significantly higher odds of clearing the virus compared to African Americans when adjusted for age and gender. None of the socio-behavioral factors including alcohol intake and drug use patterns were significant determinants of HCV clearance. Racial or ethnic differences in HCV clearance were observed in this study suggesting an important role of host genetic susceptibility factors in determining the clinical course of this disease. Further research is needed to examine these genetic associations of host-virus relationships. Copyright © 2011 Wiley Periodicals, Inc.

  1. Changes in toe clearance during treadmill walking after long-duration spaceflight.

    PubMed

    Miller, Christopher A; Peters, Brian T; Brady, Rachel R; Richards, Jason R; Ploutz-Snyder, Robert J; Mulavara, Ajitkumar P; Bloomberg, Jacob J

    2010-10-01

    Astronauts exhibit sensorimotor changes upon return from long-duration spaceflight that can result in altered gait kinematics and possibly an increased risk of tripping. Toe trajectory during locomotion is a precise motor control task involving both legs, thus providing a composite metric of locomotor control. The purpose of this study was to determine whether astronauts are at an increased risk of tripping after their return from long-duration spaceflight. This was accomplished by assessing the pre- to postflight changes in toe clearance during treadmill walking. Ten crewmembers walked on a treadmill while performing a visual-acuity task pre- and postflight. In the three subjects on whom landing day data were available, each exhibited a characteristic of increased tripping risk on landing day: either a decreased median toe clearance or an increased interquartile range (a measure of variance). For all crewmembers, toe clearance median and interquartile range were not significantly different from preflight for the other postflight sessions (the earliest being 1 d after landing). A follow-up analysis showed that changes in foot pitch, ankle dorsiflexion, and pelvis roll angles were significant predictors of changes in toe clearance. The landing-day observations indicated an increased risk of tripping, which may pose a hazard during locomotion immediately upon return to Earth, especially in an emergency scenario. However, tripping risk on subsequent days was not different than preflight. The joint angle analysis suggested that the crewmembers tried to reestablish their normal walking pattern postflight, instead of developing a new motor control strategy.

  2. 45 CFR 675.3 - Medical clearance criteria.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 45 Public Welfare 3 2014-10-01 2014-10-01 false Medical clearance criteria. 675.3 Section 675.3 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL SCIENCE FOUNDATION MEDICAL CLEARANCE PROCESS FOR DEPLOYMENT TO ANTARCTICA § 675.3 Medical clearance criteria. (a) The USAP shall...

  3. 45 CFR 675.3 - Medical clearance criteria.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 45 Public Welfare 3 2013-10-01 2013-10-01 false Medical clearance criteria. 675.3 Section 675.3 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL SCIENCE FOUNDATION MEDICAL CLEARANCE PROCESS FOR DEPLOYMENT TO ANTARCTICA § 675.3 Medical clearance criteria. (a) The USAP shall...

  4. 45 CFR 675.3 - Medical clearance criteria.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 45 Public Welfare 3 2011-10-01 2011-10-01 false Medical clearance criteria. 675.3 Section 675.3 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL SCIENCE FOUNDATION MEDICAL CLEARANCE PROCESS FOR DEPLOYMENT TO ANTARCTICA § 675.3 Medical clearance criteria. (a) The USAP shall...

  5. OBSERVATIONAL STUDY OF FINAL CLEANING AND AHERA CLEARANCE SAMPLING AT ASBESTOS-ABATEMENT SITES IN NEW JERSEY

    EPA Science Inventory

    A study was conducted during the summer of 1988 to document final cleaning procedures and evaluate Asbestos Hazard Emergency Response Act (AHERA) clearance air sampling practices used at 20 asbestos-abatement sites in New Jersey. Each abatement took place in a school building and...

  6. 24 CFR 3285.305 - Clearance under homes.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Clearance under homes. 3285.305... URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Foundations § 3285.305 Clearance under homes. A minimum clearance of 12 inches must be maintained between the lowest member of the main frame...

  7. 24 CFR 3285.305 - Clearance under homes.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Clearance under homes. 3285.305... URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Foundations § 3285.305 Clearance under homes. A minimum clearance of 12 inches must be maintained between the lowest member of the main frame...

  8. 24 CFR 3285.305 - Clearance under homes.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Clearance under homes. 3285.305... URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Foundations § 3285.305 Clearance under homes. A minimum clearance of 12 inches must be maintained between the lowest member of the main frame...

  9. 24 CFR 3285.305 - Clearance under homes.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Clearance under homes. 3285.305... URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Foundations § 3285.305 Clearance under homes. A minimum clearance of 12 inches must be maintained between the lowest member of the main frame...

  10. 24 CFR 3285.305 - Clearance under homes.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Clearance under homes. 3285.305... URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Foundations § 3285.305 Clearance under homes. A minimum clearance of 12 inches must be maintained between the lowest member of the main frame...

  11. Imaging Lung Clearance of Radiolabeled Tumor Cells to Study Mice with Normal, Activated or Depleted Natural Killer (NK) Cells

    NASA Astrophysics Data System (ADS)

    Kulkarni, P. V.; Bennett, M.; Constantinescu, A.; Arora, V.; Viguet, M.; Antich, P.; Parkey, R. W.; Mathews, D.; Mason, R. P.; Oz, O. K.

    2003-08-01

    Lung clearance of 51CR and 125I iododeoxyuridine (IUDR) labeled cancer cells assess NK cell activity. It is desirable to develop noninvasive imaging technique to assess NK activity in mice. We labeled target YAC-1 tumor cells with 125I, 111In, 99mTc, or 67Ga and injected I.V. into three groups of BALB/c mice. Animals were treated with medium (group I), 300mg/kg cyclophosmamide (CY) to kill NK cell (group II), or anti-LY49C/1) (ab')2 mAb to augment NK function (group III). Lungs were removed 15 min or 2 h later for tissue counting. Control and treated mice were imaged every 5 min with a scintillating camera for 1 h after 15 min of infusion of the 111In labeled cells. Lung clearance increased after 15 min (lodging: 60-80%) and (2 h retention: 3-7%). Similar results were obtained with all the isotopes studied. Images distinguished the control and treated mice for lung activity. Cells labeled with 111In, 99mTc or 67Ga are cleared similar to those labeled with 51Cr or 125I. NK cell destruction of tumor cells may be assessed by noninvasive imaging method either by SPECT (99mTc, 111In, 67Ga) or by PET (68Ga).

  12. Dimerization of glycoprotein Ibα is not sufficient to induce platelet clearance.

    PubMed

    Liang, X; Syed, A K; Russell, S R; Ware, J; Li, R

    2016-02-01

    ESSENTIALS: Many anti-glycoprotein (GP)Ibα antibodies induce platelet clearance in a dimer-dependent manner. Characterization of monoclonal antibodies that bind the mechanosensitive domain (MSD) of GPIbα. An anti-MSD antibody binds two copies of GPIbα in platelets but does not induce platelet clearance. The prevailing clustering model of GPIbα signaling is incorrect or needs revision. The mechanism of platelet clearance is not clear. Many antibodies binding the membrane-distal ligand-binding domain of glycoprotein (GP)Ibα induce rapid clearance of platelets and acute thrombocytopenia, which requires the bifurcated antibody structure. It was thought that binding of these antibodies induced lateral dimerization or clustering of GPIbα in the plasma membrane, which leads to downstream signaling and platelet clearance. However, many antibodies targeting GPIbβ and GPIX, which are associated with GPIbα in the GPIb-IX complex, do not induce platelet clearance, which is in contradiction to the clustering model. To test whether dimerization or clustering of GPIbα is sufficient to transmit the signal that leads to platelet clearance. We have recently raised several mAbs targeting the mechanosensitive domain (MSD) of GPIbα. Binding of these anti-MSD antibodies was characterized with biochemical methods. Their ability to stimulate platelets and induce platelet clearance in mice was assessed. Infusion of anti-MSD antibodies does not cause thrombocytopenia in mice. These antibodies show no detectable effects on platelet activation and aggregation in vitro. Further biochemical investigation showed that the anti-MSD antibody 3D1 binds two copies of GPIbα on the platelet surface. Therefore, lateral dimerization of GPIbα induced by antibody binding is not sufficient to initiate GPIb-IX signaling and induce platelet clearance. Our results suggest that a factor other than or in addition to clustering of GPIbα is required to induce platelet clearance. © 2015 International

  13. 46 CFR 56.75-10 - Joint clearance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Joint clearance. 56.75-10 Section 56.75-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Brazing § 56.75-10 Joint clearance. (a) The clearance between surfaces to be joined shall be no...

  14. Evaluation of lung clearance of inhaled pertechnegas.

    PubMed

    Fanti, S; Compagnone, G; Pancaldi, D; Franchi, R; Corbelli, C; Marengo, M; Onofri, C; Galassi, R; Levorato, M; Monetti, N

    1996-02-01

    Pertechnegas is a new ventilation agent produced by modifying the atmosphere of combustion of Technegas. Due to its rapid disappearance from the lungs, Pertechnegas has been suggested as useful in measuring pulmonary epithelial permeability. This study aimed to assess the reliability of ventilation scans with Pertechnegas to evaluate alveolar-capillary permeability. Six non-smokers with no evidence of pulmonary disease were investigated. Scintigraphic data were used to evaluate the site of Pertechnegas deposition (by assessing the Penetration Index [PI] of the gas), its clearance rate (by calculating the time to half-clearance [T1/2]) and its lung distribution (by means of a pixel-by-pixel analysis. PI measurements produced a mean value of 88.8 +/- 13.3% (range 69-117%). Time activity curves showed a fast clearance in all cases (mean T1/2 = 10.7 +/- 2.1 min, range 8.1-14.3 min). Comparison of statistical indices of uniform deposition (skewness and kurtosis) indicated satisfactory homogeneity of Pertechnegas distribution throughout the lungs. These data show that after inhalation Pertechnegas has a peripheral deposition and a homogeneous distribution in the lungs and is rapidly cleared through the alveolar-capillary barrier. In conclusion Pertechnegas can be recommended as a potential radiopharmaceutical for studying the pulmonary epithelial barrier.

  15. Compressor airfoil tip clearance optimization system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Little, David A.; Pu, Zhengxiang

    2015-08-18

    A compressor airfoil tip clearance optimization system for reducing a gap between a tip of a compressor airfoil and a radially adjacent component of a turbine engine is disclosed. The turbine engine may include ID and OD flowpath boundaries configured to minimize compressor airfoil tip clearances during turbine engine operation in cooperation with one or more clearance reduction systems that are configured to move the rotor assembly axially to reduce tip clearance. The configurations of the ID and OD flowpath boundaries enhance the effectiveness of the axial movement of the rotor assembly, which includes movement of the ID flowpath boundary.more » During operation of the turbine engine, the rotor assembly may be moved axially to increase the efficiency of the turbine engine.« less

  16. Relationship between rhinosinusitis symptoms and mucociliary clearance time.

    PubMed

    Boatsman, Justin E; Calhoun, Karen H; Ryan, Matthew W

    2006-03-01

    To determine the correlation between rhinosinusitis symptoms as assessed by the Sino-Nasal Outcomes Test-20 (SNOT-20) and mucociliary clearance as assessed by the saccharin method. This was a cross-sectional study of 50 adult volunteers. Subjects completed the SNOT-20, and mucociliary clearance was determined with the saccharine method. Correlation coefficients (Spearman's Rho) were calculated for the global SNOT-20 score. The SNOT-20 scores varied from 20 to 54 (mean 30.28) with a possible range of 20 to 100. Clearance times varied from 418 to 2865 seconds (mean 999). There was no significant correlation between global SNOT-20 score and clearance time (r = 0.196). There is no significant correlation between rhinosinusitis symptoms as assessed by SNOT-20 scores and mucociliary clearance. Mucociliary clearance is important for the health of the sinonasal cavities, but clearance time does not appear to be associated with symptom severity in the population studied. A-1b.

  17. Carbon Nanotubes in the Human Respiratory Tract-Clearance Modeling.

    PubMed

    Sturm, Robert

    2017-03-01

    Clearance of single-wall carbon nanotubes (SWCNT, diameter: 5 nm) and multi-wall carbon nanotubes (MWCNT, diameter: 50 nm) in the respiratory tract was predicted for various age groups (infants, children, adolescents, and adults). The model was founded on the assumption that lung clearance takes place in three distinct phases: (i) fast mucociliary clearance, (ii) slow bronchial clearance, and (iii) alveolar clearance. To each of these phases a specific fraction of deposited particles was attributed, the amount of which depended on particles' geometry and particles' deposition sites in the respiratory system. Clearance velocities were expressed by respective clearance half-times ranging from several hours in the case of fast clearance to tens of days in the case of slow clearance. Results of the simulations clearly demonstrate that for the specific deposition scenario (sitting, nasal breathing) considered here fast clearance fraction exhibits a slight decrease with increasing age, but total clearance times (i.e. time spans, within which 100% of the deposited particulate mass are removed) are rather constant among the age groups. Nanotubes deposited in the respiratory bronchioles and alveoli are usually subject to a long-term storage in these structures and, thus, may trigger malignant transformations in adjacent cells and tissues. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  18. Traffic control procedures for emergency responders.

    DOT National Transportation Integrated Search

    2006-10-01

    The objective of this study was to develop a training course and handbook to guide on-scene emergency responders responsible for controlling traffic during a roadway crash and subsequent clearance. : Traffic control is an essential component of incid...

  19. Clearance of polonium-210-enriched cigarette smoke from the rat trachea and lung.

    PubMed

    Cohen, B S; Harley, N H; Tso, T C

    1985-06-30

    The distribution and clearance of alpha radioactivity in the lungs of rats were measured after inhalation of smoke from cigarettes highly enriched in 210Po. Female Fischer rats were exposed daily for 6 months to smoke from cigarettes with 500 times the normal content of 210Po. Control rats were exposed to standard cigarette smoke. Animals were serially withdrawn and killed. After necropsy the trachea, major bronchi, larynx, and nasopharynx were examined for surface alpha activity by an etched track technique utilizing cellulose nitrate detectors. Areas of accumulated activity were seen on samples of larynx from rats exposed to the 210Po-enriched cigarettes. No other local accumulations were seen on the airways. The lower lungs were analyzed radiochemically for 210Po. Both radiochemical analysis and track measurements showed highly elevated activity concentrations in rats exposed to the 210Po-enriched cigarettes. Following withdrawal from smoking, both short- and long-term clearance components were seen. The parameters which fit the postexposure data for clearance of the lung burden cannot fit the buildup during the exposure period.

  20. High exposure, spontaneous clearance, and low incidence of active Helicobacter pylori infection: the Sorbo San Basile study.

    PubMed

    Luzza, Francesco; Suraci, Evelina; Larussa, Tiziana; Leone, Isabella; Imeneo, Maria

    2014-08-01

    A decreased incidence of Helicobacter pylori infection has been prospected to occur nowadays. To evaluate the exposure to H. pylori, prevalence and incidence of active infection, and related risk factors in the general population. In a small town of Southern Italy (932 inhabitants), 595 (3-97 years) and 157 (12-82 years) subjects among those with no evidence of active H. pylori infection participated at baseline and 10 years later, respectively. A questionnaire was administered. Active H. pylori infection was assessed by (13) C-urea breath test (UBT). Serum VacA and CagA antibodies were determined. Of 518 subjects who were evaluated by both UBT and serology, 310 (59.8%) were UBT positive, 479 (92.4%) VacA positive, and 369 (71.2%) CagA positive. Subjects UBT negative and serology positive were 169 (32%), ranging 1 (14.2%) to 29 (82.8%) from last to first decades of life. Age, female gender, and people per room were independent risk factors for subjects UBT positive compared to those UBT negative and serology positive. Ten years later, subjects who became UBT positive were four of 157 (0.25% per year) while those who became seropositive for VacA and/or CagA were 17 of 26 (6.5% per year). H. pylori infection is highly dynamic with wide range of spontaneous clearance. It is easily cleared in the first decades of life, more recent years, less crowded homes, and males. It disappears and recurs more often than it was previously thought, implying that the current decline in its prevalence is due to real clearance instead of a fall in infection rate. © 2014 John Wiley & Sons Ltd.

  1. CDC's Emergency Management Program activities - worldwide, 2003-2012.

    PubMed

    2013-09-06

    In 2003, recognizing the increasing frequency and complexity of disease outbreaks and disasters and a greater risk for terrorism, CDC established the Emergency Operations Center (EOC), bringing together CDC staff members who respond to public health emergencies to enhance communication and coordination. To complement the physical EOC environment, CDC implemented the Incident Management System (IMS), a staffing structure and set of standard operational protocols and services to support and monitor CDC program-led responses to complex public health emergencies. The EOC and IMS are key components of CDC's Emergency Management Program (EMP), which applies emergency management principles to public health practice. To enumerate activities conducted by the EMP during 2003-2012, CDC analyzed data from daily reports and activity logs. The results of this analysis determined that, during 2003-2012, the EMP fully activated the EOC and IMS on 55 occasions to support responses to infectious disease outbreaks, natural disasters, national security events (e.g., conventions, presidential addresses, and international summits), mass gatherings (e.g., large sports and social events), and man-made disasters. On 109 other occasions, the EMP was used to support emergency responses that did not require full EOC activation, and the EMP also conducted 30 exercises and drills. This report provides an overview of those 194 EMP activities.

  2. 78 FR 64523 - Agency Information Collection Activities: Vessel Entrance or Clearance Statement

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-29

    ... respondents or record keepers from the collection of information (a total capital/startup costs and operations... vessel data at time of formal entrance and clearance in U.S. ports. The form allows the master to attest... Responses per Respondent: 22. Estimated Total Annual Responses: 264,000. Estimated Time per Response: 30...

  3. Study of blade clearance effects on centrifugal pumps

    NASA Technical Reports Server (NTRS)

    Hoshide, R. K.; Nielson, C. E.

    1972-01-01

    A program of analysis, design, fabrication, and testing has been conducted to develop and experimentally verify analytical models to predict the effects of impeller blade clearance on centrifugal pumps. The effect of tip clearance on pump efficiency, and the relationship between the head coefficient and torque loss with tip clearance was established. Analysis were performed to determine the cost variation in design, manufacture, and test that would occur between unshrouded and shrouded impellers. An impeller, representative of typical rocket engine impellers, was modified by removing its front shroud to permit variation of its blade clearances. It was tested in water with special instrumentation to provide measurements of blade surface pressures during operation. Pump performance data were obtained from tests at various impeller tip clearances. Blade pressure data were obtained at the nominal tip clearance. Comparisons of predicted and measured data are given.

  4. Rate-Based Model Predictive Control of Turbofan Engine Clearance

    NASA Technical Reports Server (NTRS)

    DeCastro, Jonathan A.

    2006-01-01

    An innovative model predictive control strategy is developed for control of nonlinear aircraft propulsion systems and sub-systems. At the heart of the controller is a rate-based linear parameter-varying model that propagates the state derivatives across the prediction horizon, extending prediction fidelity to transient regimes where conventional models begin to lose validity. The new control law is applied to a demanding active clearance control application, where the objectives are to tightly regulate blade tip clearances and also anticipate and avoid detrimental blade-shroud rub occurrences by optimally maintaining a predefined minimum clearance. Simulation results verify that the rate-based controller is capable of satisfying the objectives during realistic flight scenarios where both a conventional Jacobian-based model predictive control law and an unconstrained linear-quadratic optimal controller are incapable of doing so. The controller is evaluated using a variety of different actuators, illustrating the efficacy and versatility of the control approach. It is concluded that the new strategy has promise for this and other nonlinear aerospace applications that place high importance on the attainment of control objectives during transient regimes.

  5. 48 CFR 245.602-70 - Plant clearance procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Plant clearance procedures... Disposal 245.602-70 Plant clearance procedures. Follow the procedures at PGI 245.602-70 for establishing and processing a plant clearance case. ...

  6. 48 CFR 245.602-70 - Plant clearance procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Plant clearance procedures... Disposal 245.602-70 Plant clearance procedures. Follow the procedures at PGI 245.602-70 for establishing and processing a plant clearance case. ...

  7. 48 CFR 245.602-70 - Plant clearance procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Plant clearance procedures... Disposal 245.602-70 Plant clearance procedures. Follow the procedures at PGI 245.602-70 for establishing and processing a plant clearance case. ...

  8. 48 CFR 245.602-70 - Plant clearance procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Plant clearance procedures... Disposal 245.602-70 Plant clearance procedures. Follow the procedures at PGI 245.602-70 for establishing and processing a plant clearance case. ...

  9. Integrating the Clearance in NPP Residual Material Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garcia-Bermejo, R.; Lamela, B.

    Previous Experiences in decommissioning projects are being used to optimize the residual material management in NPP, metallic scrap usually. The approach is based in the availability of a materials Clearance MARSSIM-based methodology developed and licensed in Spain. A typical project includes the integration of segregation, decontamination, clearance, quality control and quality assurance activities. The design is based in the clearance methodology features translating them into standard operational procedures. In terms of ecological taxes and final disposal costs, significant amounts of money could be saved with this type of approaches. The last clearance project managed a total amount of 405 tonsmore » scrap metal and a similar amount of other residual materials occupying a volume of 1500 m{sup 3}. After less than a year of field works 251 tons were finally recycled in a non-licensed smelting facility. The balance was disposed as LILW. In the planning phase the estimated cost savings were 4.5 Meuro. However, today a VLLW option is available in European countries so, the estimated cost savings are reduced to 1.2 Meuro. In conclusion: the application of materials clearance in NPP decommissioning lessons learnt to the NPP residual material management is an interesting management option. This practice is currently going on in Spanish NPP and, in a preliminary view, is consistent with the new MARSAME Draft. An interesting parameter is the cost of 1 m3 of recyclable scrap. The above estimates are very project specific because in the segregation process other residual materials were involved. If the effect of this other materials is removed the estimated Unit Cost were in this project around 1700 euro/m{sup 3}, this figure is clearly below the above VLLW disposal cost of 2600 euro. In a future project it appears feasible to descend to 839 euro/m{sup 3} and if it became routine values and is used in big Decommissioning projects, around 600 euro/m{sup 3} or below

  10. 76 FR 50993 - Agency Information Collection Activities: Proposed Collection; Comment Request-Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-17

    ...: Proposed Collection; Comment Request--Generic Clearance to Conduct Methodological Testing, Surveys, Focus... proposed information collection. This information collection will conduct research by methodological... Methodological Testing, Surveys, Focus Groups, and Related Tools to Improve the Management of Federal Nutrition...

  11. Effect of neurotrauma on hepatic drug clearance.

    PubMed

    Boucher, B A; Kuhl, D A; Fabian, T C; Robertson, J T

    1991-11-01

    Lorazepam, antipyrine, and indocyanine green were administered to 10 patients with severe head injuries as marker substrates of hepatic glucuronidation, oxidation, and hepatic blood flow, respectively. Pharmacokinetic parameter estimates were determined at baseline (20 to 80 hours after injury) and up to three additional times thereafter (study days 4, 7, and 14). Antipyrine clearance was increased significantly from baseline (0.50 +/- 0.31 ml/min/kg) on study days 4, 7, and 14 (p less than 0.0001). Increases in antipyrine clearance from baseline to the last study day were observed in all study patients ranging from 14% to 207%. A significant increase was also observed in lorazepam clearance on study day 14 relative to baseline (1.39 +/- 0.56 ml/min/kg) (p less than 0.005). Increases in lorazepam clearance occurred in seven of nine patients over time ranging from 9% to 130%. The unbound fraction of lorazepam did not change significantly over the study period. Likewise, no significant change was observed in the clearance of indocyanine green over time. Antipyrine clearance and alpha 1-acid glycoprotein (r = 0.41), and lorazepam clearance and C-reactive protein (r = -0.38) were significantly correlated (p less than 0.05). Similarly, antipyrine and lorazepam clearances were significantly correlated with injury severity based on the Acute Physiologic and Chronic Health Evaluation (APACHE II) score (r = -0.43 and r = -0.37, respectively). These findings suggest that hepatic oxidative and conjugative metabolism increase significantly over time in patients after acute head injury. An awareness of the potential for pharmacokinetic alterations in similarly metabolized drugs used for patients with severe head injuries is recommended.

  12. Turbine blade tip clearance measurement using a skewed dual-beam fiber optic sensor

    NASA Astrophysics Data System (ADS)

    Ye, De-chao; Duan, Fa-jie; Guo, Hao-tian; Li, Yangzong; Wang, Kai

    2012-08-01

    Optimization and active control of the tip clearance of turbine blades has been identified as a key to improve fuel efficiency, reduce emission, and increase service life of the engine. However, reliable and real-time tip clearance measurement is difficult due to the adverse environmental conditions that are typically found in a turbine. We describe a dual-beam fiber optic measurement system that can measure the tip timing and tip clearance simultaneously. Because the tip timing information is used to calculate the tip clearance, the method is insensitive to the signal intensity variation caused by fluctuations in environmental conditions such as light source instability, contamination, and blade tip imperfection. The system was calibrated and tested using experimental rotors. The test results indicated a high resolution of 4.5 μm and measurement accuracy of ±20 μm over the rotation speed range of 2000 to 10,000 rpm.

  13. Simple sampling strategy for measuring inulin renal clearance.

    PubMed

    Horio, Masaru; Imai, Enyu; Yasuda, Yoshinari; Hishida, Akira; Matsuo, Seiichi

    2009-02-01

    In the standard method of inulin clearance (Cin), three sets of serum and urine samples are collected during a 2-hour clearance period. For a practical use of this method, sampling should be the minimal number allowable while still providing enough accuracy. The aim of this study was to evaluate the validity of inulin renal clearance with assumed single urine collection with a period such as 30, 60 or 90 minutes. Inulin clearance data collected by the standard method from 737 individuals were used. Changes of serum inulin concentrations between 45 and 105 minutes after the start of the infusion were analyzed. We used first urine collection to calculate the inulin clearance with single urine collection (Cin-30 min). We assumed single urine collection for 60 or 90 minutes by combining the urine data of the consecutive 30-minute periods. Inulin clearances (Cin-60 min, Cin-90 min) were calculated from the assumed single urine collections, respectively. Serum inulin concentration did not reach equilibrium during the clearance period. It increased in subjects with low glomerular filtration rate (GFR) and decreased in subjects with normal GFR. The amount of the change was small and -0.5 +/- 12.6% in subjects with GFR over 30 ml/min per 1.73 m(2). Cin-30 min, Cin-60 min and Cin-90 min showed high correlation coefficients against Cin-ST (0.962, 0.988 and 0.998, respectively). Systemic biases in these clearances were negligible (under 1 ml/min per 1.73 m(2)). Root mean square error (RMSE) were 10.4, 5.3 and 2.3 ml/min per 1.73 m(2) for Cin-30 min, Cin-60 min and Cin-90 min, respectively. These data indicated that accuracy of inulin clearance depends on the duration of the urine collection period. Inulin clearance with a single urine collection is a convenient method. We showed that single urine collection for 30 minutes or a longer period has reasonable accuracy in calculation of inulin clearance. We propose a method of inulin clearance with single urine collection for 60

  14. Effects of Long-duration Space Flight on Toe Clearance During Treadmill Walking

    NASA Technical Reports Server (NTRS)

    Miller, Chris; Peters, Brian; Brady, Rachel; Mulavara, Ajitkumar; Richards, Jason; Hayat, Matthew; Bloomberg, Jacob

    2008-01-01

    Upon returning from long-duration space flight, astronauts and cosmonauts must overcome physiologic and sensorimotor changes induced by prolonged exposure to microgravity as they readapt to a gravitational environment. Their compromised balance and coordination lead to an altered and more variable walking pattern (Bloomberg & Mulavara, 2003; McDonald, et al., 1996). Toe trajectory during the swing phase of locomotion has been identified as a precise motor control task (Karst, et al., 1999), thus providing an indication of the coordination of the lower limbs (Winter, 1992). Failure to achieve sufficient toe clearance may put the crew member at a greater risk of tripping and falling, especially if an emergency egress from the vehicle should be necessary upon landing. The purpose of this study was to determine the pre- to post-flight changes in toe clearance in crew members returning from long-duration missions and the recovery thereafter.

  15. 78 FR 77027 - Overhead Clearance (Air-Draft) Accidents

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-20

    ... No. USCG-2013-0466] Overhead Clearance (Air-Draft) Accidents AGENCY: Coast Guard, DHS. ACTION... clearance (air-draft) accidents. In its petition, which calls for vessel masters to be provided with accurate vertical air draft information, a maritime organization has described 16 overhead clearance...

  16. Confusion in Using Pre-Departure Clearances

    DOT National Transportation Integrated Search

    1996-12-20

    In 1990, the FAA implemented the Pre-Departure Clearance (PDC) program at a : number of U.S. airports. This system allows pilots to obtain IFR clearances : through aircraft ACARS units prior to taxi-out, thus eliminating the need for : verbal communi...

  17. Aerial Refueling Clearance Initiation Request

    DTIC Science & Technology

    2016-07-14

    and receiver agencies. The AR Clearance Initiation Request document recognizes the requirement for definitive aerial refueling agreements between...and contractual tanker support requests from one organization or nation to another. The AR Clearance Initiation Request document is not intended to...proprietary, sensitive, classified or otherwise restricted information. ARSAG documents, as prepared, are not DOD, MOD or NATO standards, but provide

  18. 78 FR 44133 - Agency Information Collection Activities; Proposed Collection; Comment Request: Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-23

    ... Qualitative Feedback on Agency Service Delivery, National Institute of Neurological Disorders and Stroke... Qualitative Feedback on Agency Service Delivery'' to OMB for approval under the Paperwork Reduction Act ([email protected] . SUPPLEMENTARY INFORMATION: Title: Generic Clearance for the Collection of Qualitative...

  19. 78 FR 21118 - Agency Information Collection Activities; Comment Request; Streamlined Clearance Process for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-09

    ...; Comment Request; Streamlined Clearance Process for Discretionary Grants AGENCY: Department of Education... also helps the public understand the Department's information collection requirements and provide the... for Discretionary Grants OMB Control Number: 1894-0001 Type of Review: An extension of an existing...

  20. 76 FR 74802 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-01

    .... Currie, Program Analyst, Office of policy for Extramural Research Administration, 6705 Rockledge Drive... perceptions and opinions, but are not statistical surveys that yield quantitative results that can be... generic clearance for qualitative information will not be used for quantitative information collections...

  1. Alveolar Edema Fluid Clearance and Acute Lung Injury

    PubMed Central

    Berthiaume, Yves; Matthay, Michael A.

    2009-01-01

    Although lung-protective ventilation strategies have substantially reduced mortality of acute lung injury patients there is still a need for new therapies that can further decrease mortality in patients with acute lung injury. Studies of epithelial ion and fluid transport across the distal pulmonary epithelia have provided important new concepts regarding potential new therapies for acute lung injury. Overall, there is convincing evidence that the alveolar epithelium is not only a tight epithelial barrier that resists the movement of edema fluid into the alveoli, but it is also actively involved in the transport of ions and solutes, a process that is essential for edema fluid clearance and the resolution of acute lung injury. The objective of this article is to consider some areas of recent progress in the field of alveolar fluid transport under normal and pathologic conditions. Vectorial ion transport across the alveolar and distal airway epithelia is the primary determinant of alveolar fluid clearance. The general paradigm is that active Na+ and Cl− transport drives net alveolar fluid clearance, as demonstrated in several different species, including the human lung. Although these transport processes can be impaired in severe lung injury, multiple experimental studies suggest that upregulation of Na+ and Cl− transport might be an effective therapy in acute lung injury. We will review mechanisms involved in pharmacological modulation of ion transport in lung injury with a special focus on the use of β-adrenergic agonists which has generated considerable interest and is a promising therapy for clinical acute lung injury. PMID:17604701

  2. 48 CFR 945.670-1 - Plant clearance function.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Plant clearance function... MANAGEMENT GOVERNMENT PROPERTY Reporting, Reutilization, and Disposal 945.670-1 Plant clearance function. If the plant clearance function has not been formally delegated to another Federal agency, the...

  3. 48 CFR 945.670-1 - Plant clearance function.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 5 2013-10-01 2013-10-01 false Plant clearance function... MANAGEMENT GOVERNMENT PROPERTY Reporting, Reutilization, and Disposal 945.670-1 Plant clearance function. If the plant clearance function has not been formally delegated to another Federal agency, the...

  4. Shear joint capability versus bolt clearance

    NASA Technical Reports Server (NTRS)

    Lee, H. M.

    1992-01-01

    The results of a conservative analysis approach into the determination of shear joint strength capability for typical space-flight hardware as a function of the bolt-hole clearance specified in the design are presented. These joints are comprised of high-strength steel fasteners and abutments constructed of aluminum alloys familiar to the aerospace industry. A general analytical expression was first arrived at which relates bolt-hole clearance to the bolt shear load required to place all joint fasteners into a shear transferring position. Extension of this work allowed the analytical development of joint load capability as a function of the number of fasteners, shear strength of the bolt, bolt-hole clearance, and the desired factor of safety. Analysis results clearly indicate that a typical space-flight hardware joint can withstand significant loading when less than ideal bolt hole clearances are used in the design.

  5. 76 FR 79702 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-22

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential... Qualitative Feedback on Agency Service Delivery AGENCY: National Institute of Mental Health (NIMH), HHS... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  6. 78 FR 40729 - Agency Information Collection Activities; Proposed Collection; Comment Request: Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-08

    ... precision requirements or power calculations that justify the proposed sample size, the expected response... Qualitative Feedback on Agency Service Delivery AGENCY: Washington Headquarters Service (WHS), DOD. ACTION: 30... (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...

  7. 76 FR 81014 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-27

    ... of Qualitative Feedback on Agency Service Delivery AGENCY: Office of Hazardous Materials Safety... Collection of Qualitative Feedback on Agency Service Delivery'' to the Office of Management and Budget (OMB...: Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery Abstract. The...

  8. 78 FR 33097 - Agency Information Collection Activities; Proposed Collection; Comment Request: Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-03

    ... Qualitative Feedback on Agency Service Delivery, National Institute of Neurological Disorders and Stroke... Qualitative Feedback on Agency Service Delivery'' to OMB for approval under the Paperwork Reduction Act (PRA... . SUPPLEMENTARY INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service...

  9. 76 FR 55398 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-07

    ... precision requirements or power calculations that justify the proposed sample size, the expected response... Qualitative Feedback on Agency Service Delivery AGENCY: National Institutes of Health, Eunice Kennedy Shriver...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...

  10. 76 FR 38355 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-30

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential... of Qualitative Feedback on Agency Service Delivery AGENCY: Architectural and Transportation Barriers...: ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to the Office of...

  11. 76 FR 13698 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-14

    ... of Qualitative Feedback on Agency Service Delivery AGENCY: Federal Transit Administration, DOT... Qualitative Feedback on Agency Service Delivery'' to OMB for approval under the Paperwork Reduction Act (PRA... INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...

  12. 76 FR 64356 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-18

    ... Genevieve deAlmeida-Morris, Health Research Evaluator, Office of Science Policy and Communications, National... opinions, but are not statistical surveys that yield quantitative results that can be generalized to the... generic clearance for qualitative information will not be used for quantitative information collections...

  13. 78 FR 5780 - Agency Information Collection Activities: Proposed Collection, Comment Request: Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-28

    ... could change significantly based on the collection method ultimately used in the research. Estimated..., Comment Request: Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... qualitative consumer and stakeholder feedback in an efficient, timely manner to facilitate service delivery...

  14. 77 FR 75110 - Agency Information Collection Activities: Proposed Collection; Comment Request-Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-19

    ...: Proposed Collection; Comment Request--Generic Clearance To Conduct Formative Research AGENCY: Food and.... This information collection will conduct research in support of FNS' goal of delivering science-based... target audience, FNS plans to conduct data collections that involve formative research including focus...

  15. 76 FR 43353 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-20

    ... and opinions, but are not statistical surveys that yield quantitative results that can be generalized... generic clearance for qualitative information will not be used for quantitative information collections... for submission for other generic mechanisms that are designed to yield quantitative results. The...

  16. 15 CFR 752.15 - Export clearance.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Export clearance. 752.15 Section 752... OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE EXPORT ADMINISTRATION REGULATIONS SPECIAL COMPREHENSIVE LICENSE § 752.15 Export clearance. (a) Shipper's Export Declaration (SED) or Automated Export...

  17. 14 CFR 1260.63 - Customs clearance and visas.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 5 2011-01-01 2010-01-01 true Customs clearance and visas. 1260.63 Section 1260.63 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION GRANTS AND COOPERATIVE AGREEMENTS General Special Conditions § 1260.63 Customs clearance and visas. Customs Clearance and Visas (For...

  18. 14 CFR 1260.63 - Customs clearance and visas.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Customs clearance and visas. 1260.63 Section 1260.63 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION GRANTS AND COOPERATIVE AGREEMENTS General Special Conditions § 1260.63 Customs clearance and visas. Customs Clearance and Visas (For...

  19. 14 CFR 1260.63 - Customs clearance and visas.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 5 2013-01-01 2013-01-01 false Customs clearance and visas. 1260.63 Section 1260.63 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION GRANTS AND COOPERATIVE AGREEMENTS General Special Conditions § 1260.63 Customs clearance and visas. Customs Clearance and Visas (For...

  20. 14 CFR 1260.63 - Customs clearance and visas.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 5 2012-01-01 2012-01-01 false Customs clearance and visas. 1260.63 Section 1260.63 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION GRANTS AND COOPERATIVE AGREEMENTS General Special Conditions § 1260.63 Customs clearance and visas. Customs Clearance and Visas (For...

  1. 19 CFR 122.77 - Clearance certificate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Clearance certificate. 122.77 Section 122.77 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY AIR COMMERCE REGULATIONS Documents Required for Clearance and Permission To Depart; Electronic...

  2. Clearance of polonium-210-enriched cigarette smoke from the rat trachea and lung

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cohen, B.S.; Harley, N.H.; Tso, T.C.

    The distribution and clearance of alpha radioactivity in the lungs of rats were measured after inhalation of smoke from cigarettes highly enriched in /sup 210/Po. Female Fischer rats were exposed daily for 6 months to smoke from cigarettes with 500 times the normal content of /sup 210/Po. Control rats were exposed to standard cigarette smoke. Animals were serially withdrawn and killed. After necropsy the trachea, major bronchi, larynx, and nasopharynx were examined for surface alpha activity by an etched track technique utilizing cellulose nitrate detectors. Areas of accumulated activity were seen on samples of larynx from rats exposed to themore » /sup 210/Po-enriched cigarettes. No other local accumulations were seen on the airways. The lower lungs were analyzed radiochemically for /sup 210/Po. Both radiochemical analysis and track measurements showed highly elevated activity concentrations in rats exposed to the /sup 210/Po-enriched cigarettes. Following withdrawal from smoking, both short- and long-term clearance components were seen. The parameters which fit the postexposure data for clearance of the lung burden cannot fit the buildup during the exposure period.« less

  3. The clearance mechanism of chilled blood platelets.

    PubMed

    Hoffmeister, Karin M; Felbinger, Thomas W; Falet, Hervé; Denis, Cécile V; Bergmeier, Wolfgang; Mayadas, Tanya N; von Andrian, Ulrich H; Wagner, Denisa D; Stossel, Thomas P; Hartwig, John H

    2003-01-10

    Platelet transfusion is a very common lifesaving medical procedure. Not widely known is the fact that platelets, unlike other blood cells, rapidly leave the circulation if refrigerated prior to transfusion. This peculiarity requires blood services to store platelets at room temperature, limiting platelet supplies for clinical needs. Here, we describe the mechanism of this clearance system, a longstanding mystery. Chilling platelets clusters their von Willebrand (vWf) receptors, eliciting recognition of mouse and human platelets by hepatic macrophage complement type 3 (CR3) receptors. CR3-expressing but not CR3-deficient mice exposed to cold rapidly decrease platelet counts. Cooling primes platelets for activation. We propose that platelets are thermosensors, primed at peripheral sites where most injuries occurred throughout evolution. Clearance prevents pathologic thrombosis by primed platelets. Chilled platelets bind vWf and function normally in vitro and ex vivo after transfusion into CR3-deficient mice. Therefore, GPIb modification might permit cold platelet storage.

  4. 76 FR 13977 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-15

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... of Qualitative Feedback on Agency Service Delivery AGENCY: Office of the Secretary/Office of the...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for...

  5. 77 FR 72361 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-05

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential... Qualitative Feedback on Agency Service Delivery SUMMARY: As part of a Federal Government-wide effort to... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  6. 76 FR 31383 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-31

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods...; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Peace... Qualitative Feedback on Agency Service Delivery '' to OMB for approval under the Paperwork Reduction Act (PRA...

  7. 78 FR 23755 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-22

    ... justify the proposed sample size, the expected response rate, methods for assessing potential non-response... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Qualitative Feedback on Agency Service Delivery '' for approval under the Paperwork Reduction Act (PRA) (44 U...

  8. 76 FR 44938 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-27

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential... Qualitative Feedback on Agency Service Delivery: National Cancer Center (NCI) ACTION: 30-Day notice of... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  9. Emerging technologies in Si active photonics

    NASA Astrophysics Data System (ADS)

    Wang, Xiaoxin; Liu, Jifeng

    2018-06-01

    Silicon photonics for synergistic electronic–photonic integration has achieved remarkable progress in the past two decades. Active photonic devices, including lasers, modulators, and photodetectors, are the key challenges for Si photonics to meet the requirement of high bandwidth and low power consumption in photonic datalinks. Here we review recent efforts and progress in high-performance active photonic devices on Si, focusing on emerging technologies beyond conventional foundry-ready Si photonics devices. For emerging laser sources, we will discuss recent progress towards efficient monolithic Ge lasers, mid-infrared GeSn lasers, and high-performance InAs quantum dot lasers on Si for data center applications in the near future. We will then review novel modulator materials and devices beyond the free carrier plasma dispersion effect in Si, including GeSi and graphene electro-absorption modulators and plasmonic-organic electro-optical modulators, to achieve ultralow power and high speed modulation. Finally, we discuss emerging photodetectors beyond epitaxial Ge p–i–n photodiodes, including GeSn mid-infrared photodetectors, all-Si plasmonic Schottky infrared photodetectors, and Si quanta image sensors for non-avalanche, low noise single photon detection and photon counting. These emerging technologies, though still under development, could make a significant impact on the future of large-scale electronicSilicon photonics for synergistic electronic-photonic integration has achieved remarkable progress in the past two decades. Active photonic devices, including lasers, modulators, and photodetectors, are the key challenges for Si photonics to meet the requirement of high bandwidth and low power consumption in photonic datalinks. Here we review recent efforts and progress in high-performance active photonic devices on Si, focusing on emerging technologies beyond conventional foundry-ready Si photonics devices. For emerging laser sources, we will discuss recent

  10. 78 FR 44099 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-23

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Qualitative Feedback on Agency Service Delivery'' for approval under the Paperwork Reduction Act (PRA) (44 U.S...

  11. Mechanisms of failed apoptotic cell clearance by phagocyte subsets in cardiovascular disease

    PubMed Central

    2013-01-01

    Recent evidence in humans indicate that defective phagocytic clearance of dying cells is linked to progression of advanced atherosclerotic lesions, the precursor to atherothrombosis, ischemic heart disease, and leading cause of death in the industrialized world. During atherogenesis, apoptotic cell turnover in the vascular wall is counterbalanced by neighboring phagocytes with high clearance efficiency, thereby limiting cellularity and maintaining lesion integrity. However, as lesions mature, phagocytic removal of apoptotic cells (efferocytosis) becomes defective, leading to secondary necrosis, expansion of plaque necrotic cores, and susceptibility to rupture. Recent genetic causation studies in experimental rodents have implicated key molecular regulators of efferocytosis in atherosclerotic progression. These include MER tyrosine kinase (MERTK), milk fat globule-EGF factor 8 (MFGE8), and complement C1q. At the cellular level, atheromata are infiltrated by a heterogenous population of professional phagocytes, comprised of monocytes, differentiated macrophages, and CD11c+ dendritic-like cells. Each cell type is characterized by disparate clearance efficiencies and varying activities of key phagocytic signaling molecules. It is in this context that we outline a working model whereby plaque necrosis and destabilization is jointly promoted by (1) direct inhibition of core phagocytic signaling pathways and (2) expansion of phagocyte subsets with poor clearance capacity. Towards identifying targets for promoting efficient apoptotic cell clearance and resolving inflammation in atherosclerosis and during ischemic heart disease and post myocardial infarction, this review will discuss potential in vivo suppressors of efferocytosis at each stage of clearance and how these putative interventional targets may differentially affect uptake at the level of vascular phagocyte subsets. PMID:20552278

  12. CF6 High Pressure Compressor and Turbine Clearance Evaluations

    NASA Technical Reports Server (NTRS)

    Radomski, M. A.; Cline, L. D.

    1981-01-01

    In the CF6 Jet Engine Diagnostics Program the causes of performance degradation were determined for each component of revenue service engines. It was found that a significant contribution to performance degradation was caused by increased airfoil tip radial clearances in the high pressure compressor and turbine areas. Since the influence of these clearances on engine performance and fuel consumption is significant, it is important to accurately establish these relatonships. It is equally important to understand the causes of clearance deterioration so that they can be reduced or eliminated. The results of factory engine tests run to enhance the understanding of the high pressure compressor and turbine clearance effects on performance are described. The causes of clearance deterioration are indicated and potential improvements in clearance control are discussed.

  13. Time-of-Flight Tip-Clearance Measurements

    NASA Technical Reports Server (NTRS)

    Dhadwal, H. S.; Kurkov, A. P.; Janetzke, D. C.

    1999-01-01

    In this paper a time-of-flight probe system incorporating the two integrated fiber optic probes which are tilted equally relative to the probe holder centerline, is applied for the first time to measure the tip clearance of an advanced fan prototype. Tip clearance is largely independent of the signal amplitude and it relies on timing measurement. This work exposes optical effects associated with the fan blade stagger angle that were absent during the original spin-rig experiment on the zero stagger rotor. Individual blade tip clearances were measured with accuracy of +/- 127-mm (+/- 0.005-in). Probe features are discussed and improvements to the design are suggested.

  14. Active-learning instruction on emergency contraception counseling.

    PubMed

    Young, Shardae; Griffin, Brooke; Vest, Kathleen

    2013-06-12

    To increase pharmacy students' knowledge of and confidence in counseling patients regarding emergency contraception and to identify any barriers to counseling patients about emergency contraception. Approximately 200 third-year pharmacy students participated in the Women's Health Therapeutics workshop at Midwestern University Chicago College of Pharmacy. Students observed a 5-minute skit of a counseling session on emergency contraception and then were asked to pair up with a classmate and practice counseling each other regarding the use of emergency contraception following a checklist of key points. One hundred eighty-nine students completed pre- and post-workshop survey instruments. Students' knowledge scores increased from 86% to 93% (p<0.001). Approximately 25% of the students stated they were confident in counseling patients on emergency contraception before completing the active-learning exercise compared to 58.5% after (p<0.001). The most common barrier to counseling that students identified on the pre- and post-workshop survey was lack of knowledge. Participation in an active-learning exercise significantly increased pharmacy students' knowledge of and confidence in counseling patients regarding emergency contraception and significantly reduced several barriers to counseling identified prior to participation.

  15. Active-Learning Instruction on Emergency Contraception Counseling

    PubMed Central

    Young, Shardae; Vest, Kathleen

    2013-01-01

    Objective. To increase pharmacy students’ knowledge of and confidence in counseling patients regarding emergency contraception and to identify any barriers to counseling patients about emergency contraception. Design. Approximately 200 third-year pharmacy students participated in the Women’s Health Therapeutics workshop at Midwestern University Chicago College of Pharmacy. Students observed a 5-minute skit of a counseling session on emergency contraception and then were asked to pair up with a classmate and practice counseling each other regarding the use of emergency contraception following a checklist of key points. Assessment. One hundred eighty-nine students completed pre- and post-workshop survey instruments. Students’ knowledge scores increased from 86% to 93% (p<0.001). Approximately 25% of the students stated they were confident in counseling patients on emergency contraception before completing the active-learning exercise compared to 58.5% after (p<0.001). The most common barrier to counseling that students identified on the pre- and post-workshop survey was lack of knowledge. Conclusion. Participation in an active-learning exercise significantly increased pharmacy students’ knowledge of and confidence in counseling patients regarding emergency contraception and significantly reduced several barriers to counseling identified prior to participation. PMID:23788815

  16. Active clearance of chest drainage catheters reduces retained blood.

    PubMed

    Sirch, Joachim; Ledwon, Miroslaw; Püski, Tamas; Boyle, Ed M; Pfeiffer, Steffen; Fischlein, Theodor

    2016-03-01

    Chest tubes are used to clear blood from around the heart and lungs after heart surgery, but they can be obstructed by a blood clot, leading to retained blood syndrome (RBS). We sought to examine the frequency of RBS and associated morbidity, and to determine the influence of a preventative active chest tube clearance (ATC) protocol on these outcomes. A multidisciplinary team developed a simple protocol to institute ATC to preventatively clear chest tubes of clot during the first 24 hours after heart surgery. An extensive educational in-service was performed before universal implementation (phase 1). We retrospectively compared data collected prospectively from 1849 patients before universal implementation (phase 0) with data from 256 patients collected prospectively after universal implementation (phase 2), and then used propensity matching for outcomes assessment. In propensity-matched patients, 19.9% of patients had interventions for RBS (phase 0). After the implementation of ATC (phase 2), the percent of patients with interventions for RBS was reduced to 11.3%, representing a 43% reduction in RBS (P = .0087). These patients had a 33% reduced incidence of postoperative atrial fibrillation from 30% (78 out of 256) in phase 0 to 20% (52 out of 256) in phase 2. (P = .013). ATC is associated with a reduced need for interventions for RBS and postoperative atrial fibrillation. Our findings underscore the importance of maintaining chest tube patency in the early hours after cardiac surgery. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  17. Lung-clearance classification of radionuclides in calcined phosphate rock dust

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalkwarf, D.R.; Jackson, P.O.

    1984-08-01

    Lung-clearance classifications for /sup 210/Pb and /sup 210/Po in airborne dust from elemental phosphorus plants were estimated for use with the lung clearance model proposed by the ICRP Task Group on Lung Dynamics. Estimates were based on measurements of dissolution rates for these radionuclides from sized dust samples into simulated lung fluid at 37/sup 0/C. The estimates were expressed in the classification terms of the model, i.e., D, W and Y, indicating lung clearance half-times of 0 to 10 days, 11 to 100 days and more than 100 days. Dust samples were obtained from two plants in the western Unitedmore » States, and dissolution trials were conducted on fractions containing particles with aerodynamic equivalent diameters (AED) of 0 to 3 ..mu..m and of 3 to 10 ..mu..m. The /sup 210/Pb and /sup 210/Po in each of these fractions were classified 100% Class Y. The specific activities of both radionuclides increased with decreasing AED of the particles. 11 references, 1 figure, 4 tables.« less

  18. Turbomachinery Clearance Control

    NASA Technical Reports Server (NTRS)

    Chupp, Raymond E.; Hendricks, Robert C.; Lattime, Scott B.; Steinetz, Bruce M.; Aksit, Mahmut F.

    2007-01-01

    Controlling interface clearances is the most cost effective method of enhancing turbomachinery performance. Seals control turbomachinery leakages, coolant flows and contribute to overall system rotordynamic stability. In many instances, sealing interfaces and coatings are sacrificial, like lubricants, giving up their integrity for the benefit of the component. They are subjected to abrasion, erosion, oxidation, incursive rubs, foreign object damage (FOD) and deposits as well as extremes in thermal, mechanical, aerodynamic and impact loadings. Tribological pairing of materials control how well and how long these interfaces will be effective in controlling flow. A variety of seal types and materials are required to satisfy turbomachinery sealing demands. These seals must be properly designed to maintain the interface clearances. In some cases, this will mean machining adjacent surfaces, yet in many other applications, coatings are employed for optimum performance. Many seals are coating composites fabricated on superstructures or substrates that are coated with sacrificial materials which can be refurbished either in situ or by removal, stripping, recoating and replacing until substrate life is exceeded. For blade and knife tip sealing an important class of materials known as abradables permit blade or knife rubbing without significant damage or wear to the rotating element while maintaining an effective sealing interface. Most such tip interfaces are passive, yet some, as for the high-pressure turbine (HPT) case or shroud, are actively controlled. This work presents an overview of turbomachinery sealing. Areas covered include: characteristics of gas and steam turbine sealing applications and environments, benefits of sealing, types of standard static and dynamics seals, advanced seal designs, as well as life and limitations issues.

  19. Clearance systems in the brain-implications for Alzheimer disease.

    PubMed

    Tarasoff-Conway, Jenna M; Carare, Roxana O; Osorio, Ricardo S; Glodzik, Lidia; Butler, Tracy; Fieremans, Els; Axel, Leon; Rusinek, Henry; Nicholson, Charles; Zlokovic, Berislav V; Frangione, Blas; Blennow, Kaj; Ménard, Joël; Zetterberg, Henrik; Wisniewski, Thomas; de Leon, Mony J

    2015-08-01

    Accumulation of toxic protein aggregates-amyloid-β (Aβ) plaques and hyperphosphorylated tau tangles-is the pathological hallmark of Alzheimer disease (AD). Aβ accumulation has been hypothesized to result from an imbalance between Aβ production and clearance; indeed, Aβ clearance seems to be impaired in both early and late forms of AD. To develop efficient strategies to slow down or halt AD, it is critical to understand how Aβ is cleared from the brain. Extracellular Aβ deposits can be removed from the brain by various clearance systems, most importantly, transport across the blood-brain barrier. Findings from the past few years suggest that astroglial-mediated interstitial fluid (ISF) bulk flow, known as the glymphatic system, might contribute to a larger portion of extracellular Aβ (eAβ) clearance than previously thought. The meningeal lymphatic vessels, discovered in 2015, might provide another clearance route. Because these clearance systems act together to drive eAβ from the brain, any alteration to their function could contribute to AD. An understanding of Aβ clearance might provide strategies to reduce excess Aβ deposits and delay, or even prevent, disease onset. In this Review, we describe the clearance systems of the brain as they relate to proteins implicated in AD pathology, with the main focus on Aβ.

  20. Clearance systems in the brain—implications for Alzheimer disease

    PubMed Central

    Tarasoff-Conway, Jenna M.; Carare, Roxana O.; Osorio, Ricardo S.; Glodzik, Lidia; Butler, Tracy; Fieremans, Els; Axel, Leon; Rusinek, Henry; Nicholson, Charles; Zlokovic, Berislav V.; Frangione, Blas; Blennow, Kaj; Ménard, Joël; Zetterberg, Henrik; Wisniewski, Thomas; de Leon, Mony J.

    2015-01-01

    Accumulation of toxic protein aggregates—amyloid-β (Aβ) plaques and hyperphosphorylated tau tangles—is the pathological hallmark of Alzheimer disease (AD). Aβ accumulation has been hypothesized to result from an imbalance between Aβ production and clearance; indeed, Aβ clearance seems to be impaired in both early and late forms of AD. To develop efficient strategies to slow down or halt AD, it is critical to understand how Aβ is cleared from the brain. Extracellular Aβ deposits can be removed from the brain by various clearance systems, most importantly, transport across the blood–brain barrier. Findings from the past few years suggest that astroglial-mediated interstitial fluid (ISF) bulk flow, known as the glymphatic system, might contribute to a larger portion of extracellular Aβ (eAβ) clearance than previously thought. The meningeal lymphatic vessels, discovered in 2015, might provide another clearance route. Because these clearance systems act together to drive eAβ from the brain, any alteration to their function could contribute to AD. An understanding of Aβ clearance might provide strategies to reduce excess Aβ deposits and delay, or even prevent, disease onset. In this Review, we describe the clearance systems of the brain as they relate to proteins implicated in AD pathology, with the main focus on Aβ. PMID:26195256

  1. Local Helioseismology of Emerging Active Regions: A Case Study

    NASA Astrophysics Data System (ADS)

    Kosovichev, Alexander G.; Zhao, Junwei; Ilonidis, Stathis

    2018-04-01

    Local helioseismology provides a unique opportunity to investigate the subsurface structure and dynamics of active regions and their effect on the large-scale flows and global circulation of the Sun. We use measurements of plasma flows in the upper convection zone, provided by the Time-Distance Helioseismology Pipeline developed for analysis of solar oscillation data obtained by Helioseismic and Magnetic Imager (HMI) on Solar Dynamics Observatory (SDO), to investigate the subsurface dynamics of emerging active region NOAA 11726. The active region emergence was detected in deep layers of the convection zone about 12 hours before the first bipolar magnetic structure appeared on the surface, and 2 days before the emergence of most of the magnetic flux. The speed of emergence determined by tracking the flow divergence with depth is about 1.4 km/s, very close to the emergence speed in the deep layers. As the emerging magnetic flux becomes concentrated in sunspots local converging flows are observed beneath the forming sunspots. These flows are most prominent in the depth range 1-3 Mm, and remain converging after the formation process is completed. On the larger scale converging flows around active region appear as a diversion of the zonal shearing flows towards the active region, accompanied by formation of a large-scale vortex structure. This process occurs when a substantial amount of the magnetic flux emerged on the surface, and the converging flow pattern remains stable during the following evolution of the active region. The Carrington synoptic flow maps show that the large-scale subsurface inflows are typical for active regions. In the deeper layers (10-13 Mm) the flows become diverging, and surprisingly strong beneath some active regions. In addition, the synoptic maps reveal a complex evolving pattern of large-scale flows on the scale much larger than supergranulation

  2. Methodological uncertainty in quantitative prediction of human hepatic clearance from in vitro experimental systems.

    PubMed

    Hallifax, D; Houston, J B

    2009-03-01

    Mechanistic prediction of unbound drug clearance from human hepatic microsomes and hepatocytes correlates with in vivo clearance but is both systematically low (10 - 20 % of in vivo clearance) and highly variable, based on detailed assessments of published studies. Metabolic capacity (Vmax) of commercially available human hepatic microsomes and cryopreserved hepatocytes is log-normally distributed within wide (30 - 150-fold) ranges; Km is also log-normally distributed and effectively independent of Vmax, implying considerable variability in intrinsic clearance. Despite wide overlap, average capacity is 2 - 20-fold (dependent on P450 enzyme) greater in microsomes than hepatocytes, when both are normalised (scaled to whole liver). The in vitro ranges contrast with relatively narrow ranges of clearance among clinical studies. The high in vitro variation probably reflects unresolved phenotypical variability among liver donors and practicalities in processing of human liver into in vitro systems. A significant contribution from the latter is supported by evidence of low reproducibility (several fold) of activity in cryopreserved hepatocytes and microsomes prepared from the same cells, between separate occasions of thawing of cells from the same liver. The large uncertainty which exists in human hepatic in vitro systems appears to dominate the overall uncertainty of in vitro-in vivo extrapolation, including uncertainties within scaling, modelling and drug dependent effects. As such, any notion of quantitative prediction of clearance appears severely challenged.

  3. [Conservative calibration of a clearance monitor system for waste material from nuclear medicine].

    PubMed

    Wanke, Carsten; Geworski, Lilli

    2014-09-01

    Clearance monitor systems are used for gross gamma measurements of waste potentially contaminated with radioactivity. These measurements are to make sure that legal requirements, e.g. clearance criteria according to the german radiation protection ordinance, are met. This means that measurement results may overestimate, but must not underestimate the true values. This paper describes a pragmatic way using a calibrated Cs-137 point source to generate a conservative calibration for the clearance monitor system used in the Medizinische Hochschule Hannover (MHH). The most important nuclides used in nuclear medicine are considered. The measurement result reliably overestimates the true value of the activity present in the waste. The calibration is compliant with the demands for conservativity and traceability to national standards. Copyright © 2014. Published by Elsevier GmbH.

  4. The sensitivity and negative predictive value of a pediatric cervical spine clearance algorithm that minimizes computerized tomography.

    PubMed

    Arbuthnot, Mary; Mooney, David P

    2017-01-01

    It is crucial to identify cervical spine injuries while minimizing ionizing radiation. This study analyzes the sensitivity and negative predictive value of a pediatric cervical spine clearance algorithm. We performed a retrospective review of all children <21years old who were admitted following blunt trauma and underwent cervical spine clearance utilizing our institution's cervical spine clearance algorithm over a 10-year period. Age, gender, International Classification of Diseases 9th Edition diagnosis codes, presence or absence of cervical collar on arrival, Injury Severity Score, and type of cervical spine imaging obtained were extracted from the trauma registry and electronic medical record. Descriptive statistics were used and the sensitivity and negative predictive value of the algorithm were calculated. Approximately 125,000 children were evaluated in the Emergency Department and 11,331 were admitted. Of the admitted children, 1023 patients arrived in a cervical collar without advanced cervical spine imaging and were evaluated using the cervical spine clearance algorithm. Algorithm sensitivity was 94.4% and the negative predictive value was 99.9%. There was one missed injury, a spinous process tip fracture in a teenager maintained in a collar. Our algorithm was associated with a low missed injury rate and low CT utilization rate, even in children <3years old. IV. Published by Elsevier Inc.

  5. 48 CFR 2452.237-75 - Clearance of contractor personnel.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Clearance of contractor... Clauses 2452.237-75 Clearance of contractor personnel. As prescribed in 2437.110(e), insert the following clause in solicitations and contracts. Clearance of Contractor Personnel (OCT 1999) (a) General. This...

  6. 78 FR 58597 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-24

    ... DePaepe, Room 126B, Federal Aviation Administration, AES-200, 6500 S. MacArthur Blvd., Oklahoma City, OK..., FAA Assistant Information Collection Clearance Officer, IT Enterprises Business Services Division, AES...

  7. 78 FR 29427 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-20

    ..., Room 126B, Federal Aviation Administration, AES-200, 6500 S. MacArthur Blvd., Oklahoma City, OK 73169... Assistant Information Collection Clearance Officer, IT Enterprises Business Services Division, AES-200. [FR...

  8. 30 CFR 56.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Warning devices for restricted clearances. 56... Loading and Dumping Sites § 56.9306 Warning devices for restricted clearances. Where restricted clearance creates a hazard to persons on mobile equipment, warning devices shall be installed in advance of the...

  9. 30 CFR 57.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Warning devices for restricted clearances. 57... Loading and Dumping Sites § 57.9306 Warning devices for restricted clearances. Where restricted clearance creates a hazard to persons on mobile equipment, warning devices shall be installed in advance of the...

  10. 30 CFR 56.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Warning devices for restricted clearances. 56... Loading and Dumping Sites § 56.9306 Warning devices for restricted clearances. Where restricted clearance creates a hazard to persons on mobile equipment, warning devices shall be installed in advance of the...

  11. 30 CFR 57.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Warning devices for restricted clearances. 57... Loading and Dumping Sites § 57.9306 Warning devices for restricted clearances. Where restricted clearance creates a hazard to persons on mobile equipment, warning devices shall be installed in advance of the...

  12. 30 CFR 57.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Warning devices for restricted clearances. 57... Loading and Dumping Sites § 57.9306 Warning devices for restricted clearances. Where restricted clearance creates a hazard to persons on mobile equipment, warning devices shall be installed in advance of the...

  13. 30 CFR 57.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Warning devices for restricted clearances. 57... Loading and Dumping Sites § 57.9306 Warning devices for restricted clearances. Where restricted clearance creates a hazard to persons on mobile equipment, warning devices shall be installed in advance of the...

  14. 30 CFR 56.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Warning devices for restricted clearances. 56... Loading and Dumping Sites § 56.9306 Warning devices for restricted clearances. Where restricted clearance creates a hazard to persons on mobile equipment, warning devices shall be installed in advance of the...

  15. 30 CFR 56.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Warning devices for restricted clearances. 56... Loading and Dumping Sites § 56.9306 Warning devices for restricted clearances. Where restricted clearance creates a hazard to persons on mobile equipment, warning devices shall be installed in advance of the...

  16. 30 CFR 57.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Warning devices for restricted clearances. 57... Loading and Dumping Sites § 57.9306 Warning devices for restricted clearances. Where restricted clearance creates a hazard to persons on mobile equipment, warning devices shall be installed in advance of the...

  17. 30 CFR 56.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Warning devices for restricted clearances. 56... Loading and Dumping Sites § 56.9306 Warning devices for restricted clearances. Where restricted clearance creates a hazard to persons on mobile equipment, warning devices shall be installed in advance of the...

  18. 78 FR 38795 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-27

    ... to the operation of an aircraft. The FAA uses this data to identify trends that may facilitate the..., 2013. Albert R. Spence, FAA Assistant Information Collection Clearance Officer, IT Enterprises Business...

  19. Selectively increasing the clearance of protein-bound uremic solutes

    PubMed Central

    Luo, Frank J.-G.; Plummer, Natalie S.; Hostetter, Thomas H.; Meyer, Timothy W.

    2012-01-01

    Background. The toxicity of bound solutes could be better evaluated if we could adjust the clearance of such solutes independent of unbound solutes. This study assessed whether bound solute clearances can be increased while maintaining urea clearance constant during the extended hours of nocturnal dialysis. Methods. Nine patients on thrice-weekly nocturnal dialysis underwent two experimental dialysis treatments 1 week apart. The experimental treatments were designed to provide the same urea clearance while providing widely different bound solute clearance. One treatment employed a large dialyzer and high dialyzate flow rate (Qd) of 800 mL/min while blood flow (Qb) was 270 mL/min. The other treatment employed a smaller dialyzer and Qd of 300 mL/min while Qb was 350 mL/min. Results. Treatment with the large dialyzer and higher Qd greatly increased the clearances of the bound solutes p-cresol sulfate (PCS: 27 ± 9 versus 14 ± 6 mL/min) and indoxyl sulfate (IS: 26 ± 8 versus 14 ± 5 mL/min) without altering the clearance of urea (204 ± 20 versus 193 ± 16 mL/min). Increasing PCS and IS clearances increased the removal of these solutes (PCS: 375 ± 200 versus 207 ± 86 mg/session; IS: 201 ± 137 versus 153 ± 74 mg/session), while urea removal was not different. Conclusions. The removal of bound solutes can thus be increased by raising the dialyzate flow and dialyzer size above the low levels sufficient to achieve target Kt/Vurea during extended treatment. Selectively increasing the clearance of bound solutes provides a potential means to test their toxicity. PMID:22231033

  20. Histaminergic regulation of natural killer cell-mediated clearance of tumour cells in mice.

    PubMed

    Asea, A; Hermodsson, S; Hellstrand, K

    1996-01-01

    Treatment of Swiss albino mice with histamine enhanced the clearance of natural killer (NK)-cell sensitive YAC-1 lymphoma and B16/F10 melanoma cells from lung tissue in vivo, but did not affect the elimination of NK-cell-insensitive P815 mastocytoma cells. The effect of histamine was apparently mediated by H2-type histamine receptors (H2R) since it was blocked by ranitidine, and H2R antagonist. Histamine did not affect clearance of tumour cells in animals depleted of NK cells in vivo by treatment with antibodies to asialo-GM1 or NK1.1. The effect of histamine was time-dependent: pretreatment with histamine for 3 h significantly augmented the clearance of YAC-1 cells, whereas, pretreatment with histamine for 5 min was ineffective. Histamine potentiated the anti-tumour properties of NK-cell activators such as interleukin-2 (IL-2) or interferon-alpha (IFN-alpha) in vivo. None of these lymphokines significantly affected the clearance of YAC-1 cells unless animals were concomitantly treated with histamine. Treatment with ranitidine alone reduced the in vivo clearance of YAC-1 cells from lungs but did not affect the clearance of NK-cell-insensitive P815 cells. Effects of ranitidine on NK-cell function in vivo were not shared by a chemical control to ranitidine, AH20239AA, thus indicating that the inhibition of NK-cells results from H2R antagonism rather than non-specific toxicity. It is concluded that histaminergic mechanisms may be involved in the regulation of NK cell function in vivo.

  1. 78 FR 63561 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-24

    ... to the operation of an aircraft. The FAA uses this data to identify trends that may facilitate the... Information Collection Clearance Officer, IT Enterprises Business Services Division, AES-200. [FR Doc. 2013...

  2. 14 CFR § 1260.63 - Customs clearance and visas.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 5 2014-01-01 2014-01-01 false Customs clearance and visas. § 1260.63... COOPERATIVE AGREEMENTS General Special Conditions § 1260.63 Customs clearance and visas. Customs Clearance and Visas (For grants or cooperative agreements with foreign organizations, this clause will be developed on...

  3. Allometric scaling for predicting human clearance of bisphenol A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Collet, Séverine H., E-mail: s.collet@envt.fr; Picard-Hagen, Nicole, E-mail: n.hagen-picard@envt.fr; Lacroix, Marlène Z., E-mail: m.lacroix@envt.fr

    The investigation of interspecies differences in bisphenol A (BPA) pharmacokinetics (PK) may be useful for translating findings from animal studies to humans, identifying major processes involved in BPA clearance mechanisms, and predicting BPA PK parameters in man. For the first time, a large range of species in terms of body weight, from 0.02 kg (mice) to 495 kg (horses) was used to predict BPA clearance in man by an allometric approach. BPA PK was evaluated after intravenous administration of BPA in horses, sheep, pigs, dogs, rats and mice. A non-compartmental analysis was used to estimate plasma clearance and steady statemore » volume of distribution and predict BPA PK parameters in humans from allometric scaling. In all the species investigated, BPA plasma clearance was high and of the same order of magnitude as their respective hepatic blood flow. By an allometric scaling, the human clearance was estimated to be 1.79 L/min (equivalent to 25.6 mL/kg.min) with a 95% prediction interval of 0.36 to 8.83 L/min. Our results support the hypothesis that there are highly efficient and hepatic mechanisms of BPA clearance in man. - Highlights: • Allometric scaling was used to predict BPA pharmacokinetic parameters in humans. • In all species, BPA plasma clearance approached hepatic blood flow. • Human BPA clearance was estimated to be 1.79 L/min.« less

  4. Transitional probability-based model for HPV clearance in HIV-1-positive adolescent females.

    PubMed

    Kravchenko, Julia; Akushevich, Igor; Sudenga, Staci L; Wilson, Craig M; Levitan, Emily B; Shrestha, Sadeep

    2012-01-01

    HIV-1-positive patients clear the human papillomavirus (HPV) infection less frequently than HIV-1-negative. Datasets for estimating HPV clearance probability often have irregular measurements of HPV status and risk factors. A new transitional probability-based model for estimation of probability of HPV clearance was developed to fully incorporate information on HIV-1-related clinical data, such as CD4 counts, HIV-1 viral load (VL), highly active antiretroviral therapy (HAART), and risk factors (measured quarterly), and HPV infection status (measured at 6-month intervals). Data from 266 HIV-1-positive and 134 at-risk HIV-1-negative adolescent females from the Reaching for Excellence in Adolescent Care and Health (REACH) cohort were used in this study. First, the associations were evaluated using the Cox proportional hazard model, and the variables that demonstrated significant effects on HPV clearance were included in transitional probability models. The new model established the efficacy of CD4 cell counts as a main clearance predictor for all type-specific HPV phylogenetic groups. The 3-month probability of HPV clearance in HIV-1-infected patients significantly increased with increasing CD4 counts for HPV16/16-like (p<0.001), HPV18/18-like (p<0.001), HPV56/56-like (p = 0.05), and low-risk HPV (p<0.001) phylogenetic groups, with the lowest probability found for HPV16/16-like infections (21.60±1.81% at CD4 level 200 cells/mm(3), p<0.05; and 28.03±1.47% at CD4 level 500 cells/mm(3)). HIV-1 VL was a significant predictor for clearance of low-risk HPV infections (p<0.05). HAART (with protease inhibitor) was significant predictor of probability of HPV16 clearance (p<0.05). HPV16/16-like and HPV18/18-like groups showed heterogeneity (p<0.05) in terms of how CD4 counts, HIV VL, and HAART affected probability of clearance of each HPV infection. This new model predicts the 3-month probability of HPV infection clearance based on CD4 cell counts and other HIV-1-related

  5. Hepatobiliary Clearance Prediction: Species Scaling From Monkey, Dog, and Rat, and In Vitro-In Vivo Extrapolation of Sandwich-Cultured Human Hepatocytes Using 17 Drugs.

    PubMed

    Kimoto, Emi; Bi, Yi-An; Kosa, Rachel E; Tremaine, Larry M; Varma, Manthena V S

    2017-09-01

    Hepatobiliary elimination can be a major clearance pathway dictating the pharmacokinetics of drugs. Here, we first compared the dose eliminated in bile in preclinical species (monkey, dog, and rat) with that in human and further evaluated single-species scaling (SSS) to predict human hepatobiliary clearance. Six compounds dosed in bile duct-cannulated (BDC) monkeys showed biliary excretion comparable to human; and the SSS of hepatobiliary clearance with plasma fraction unbound correction yielded reasonable predictions (within 3-fold). Although dog SSS also showed reasonable predictions, rat overpredicted hepatobiliary clearance for 13 of 24 compounds. Second, we evaluated the translatability of in vitro sandwich-cultured human hepatocytes (SCHHs) to predict human hepatobiliary clearance for 17 drugs. For drugs with no significant active uptake in SCHH studies (i.e., with or without rifamycin SV), measured intrinsic biliary clearance was directly scalable with good predictability (absolute average fold error [AAFE] = 1.6). Drugs showing significant active uptake in SCHH, however, showed improved predictability when scaled based on extended clearance term (AAFE = 2.0), which incorporated sinusoidal uptake along with a global scaling factor for active uptake and the canalicular efflux clearance. In conclusion, SCHH is a useful tool to predict human hepatobiliary clearance, whereas BDC monkey model may provide further confidence in the prospective predictions. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  6. 19 CFR 4.61 - Requirements for clearance.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... transported in-bond, or when they have unentered foreign merchandise aboard. For the purposes of the vessel clearance requirements, merchandise transported in-bond does not include bonded ship's stores or supplies. While American vessels transporting unentered foreign merchandise must fully comply with usual clearance...

  7. 48 CFR 952.204-73 - Facility clearance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....204-73 Section 952.204-73 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND... granted by the Secretary of Energy. In addition, a Facility Clearance and foreign ownership, control and... Department of Energy Facility Clearance generally need not resubmit the following foreign ownership...

  8. 48 CFR 952.204-73 - Facility clearance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....204-73 Section 952.204-73 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND... granted by the Secretary of Energy. In addition, a Facility Clearance and foreign ownership, control and... Department of Energy Facility Clearance generally need not resubmit the following foreign ownership...

  9. 48 CFR 952.204-73 - Facility clearance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....204-73 Section 952.204-73 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND... granted by the Secretary of Energy. In addition, a Facility Clearance and foreign ownership, control and... Department of Energy Facility Clearance generally need not resubmit the following foreign ownership...

  10. 48 CFR 952.204-73 - Facility clearance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....204-73 Section 952.204-73 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND... granted by the Secretary of Energy. In addition, a Facility Clearance and foreign ownership, control and... Department of Energy Facility Clearance generally need not resubmit the following foreign ownership...

  11. 48 CFR 952.204-73 - Facility clearance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....204-73 Section 952.204-73 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND... granted by the Secretary of Energy. In addition, a Facility Clearance and foreign ownership, control and... Department of Energy Facility Clearance generally need not resubmit the following foreign ownership...

  12. Anal human papillomavirus in HIV-uninfected men who have sex with men: incidence and clearance rates, duration of infection, and risk factors.

    PubMed

    Donà, M G; Vescio, M F; Latini, A; Giglio, A; Moretto, D; Frasca, M; Benevolo, M; Rollo, F; Colafigli, M; Cristaudo, A; Giuliani, M

    2016-12-01

    Little is known regarding the natural history of anal human papillomavirus (HPV) infection. We aimed to evaluate incidence and clearance rates, their risk factors, and duration of anal HPV infection in HIV-uninfected men who have sex with men (MSM). A longitudinal study was conducted. Anal samples were analysed using the Linear Array HPV Genotyping test. Incidence and clearance rates, and corresponding risk factors, were estimated using a two-state Markov model. Overall, 155 MSM (median age 33.4 years) attending the largest sexually transmitted infection (STI) centre in Rome, Italy, were followed for a median of 12.2 months (Q1-Q3: 7.0-18.1). Incidence and clearance rates for any HPV were 85.6 (95% CI: 58.4-125.4) and 35.6 (95% CI: 24.7-51.5) × 1000 person-months, respectively; the median duration of infection was 9.4 months (Q1-Q3: 7.5-12.1). Receptive anal sex emerged as the only risk factor for the acquisition of any HPV (Hazard Ratio, HR = 2.65, 95% CI: 1.16-6.06). The incidence rates for carcinogenic and non-carcinogenic types were 42.3 (95% CI: 29.2-61.4) and 29.2 (95% CI: 19.5-43.7) × 1000 person-months, respectively (p = 0.13); their clearance rates were 62.9 (95% CI: 45.1-87.7) and 65.7 (95% CI: 47.4-91.0) × 1000 person-months, respectively (p = 0.83). HPV16 showed the lowest clearance rate among carcinogenic types (59.7 × 1000 person-months), and a duration of infection of 16.8 months. In conclusion, a higher incidence rate was observed for carcinogenic compared to non-carcinogenic HPV types, although the difference was not significant. HPV16 emerged as the type with the longest duration of infection and the lowest clearance rate among carcinogenic types. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  13. Clinical review: Drug metabolism and nonrenal clearance in acute kidney injury

    PubMed Central

    Vilay, A Mary; Churchwell, Mariann D; Mueller, Bruce A

    2008-01-01

    Decreased renal drug clearance is an obvious consequence of acute kidney injury (AKI). However, there is growing evidence to suggest that nonrenal drug clearance is also affected. Data derived from human and animal studies suggest that hepatic drug metabolism and transporter function are components of nonrenal clearance affected by AKI. Acute kidney injury may also impair the clearance of formed metabolites. The fact that AKI does not solely influence kidney function may have important implications for drug dosing, not only of renally eliminated drugs but also of those that are hepatically cleared. A review of the literature addressing the topic of drug metabolism and clearance alterations in AKI reveals that changes in nonrenal clearance are highly complicated and poorly studied, but they may be quite common. At present, our understanding of how AKI affects drug metabolism and nonrenal clearance is limited. However, based on the available evidence, clinicians should be cognizant that even hepatically eliminated drugs and formed drug metabolites may accumulate during AKI, and renal replacement therapy may affect nonrenal clearance as well as drug metabolite clearance. PMID:19040780

  14. 76 FR 28100 - Activities: Proposed Collection; Comment Request; Generic Clearance for the Collection of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-13

    ... statistical surveys that yield quantitative results that can be generalized to the population of study. This... CONTACT: Carlos Manjarrez, Director for Planning, Research and Evaluation, Institute of Museum and Library.... This type of generic clearance for qualitative information will not be used for quantitative...

  15. Protectin DX increases alveolar fluid clearance in rats with lipopolysaccharide-induced acute lung injury.

    PubMed

    Zhuo, Xiao-Jun; Hao, Yu; Cao, Fei; Yan, Song-Fan; Li, Hui; Wang, Qian; Cheng, Bi-Huan; Ying, Bin-Yu; Smith, Fang Gao; Jin, Sheng-Wei

    2018-04-27

    Acute respiratory distress syndrome is a life-threatening critical syndrome resulting largely from the accumulation of and the inability to clear pulmonary edema. Protectin DX, an endogenously produced lipid mediator, is believed to exert anti-inflammatory and pro-resolution effects. Protectin DX (5 µg/kg) was injected i.v. 8 h after LPS (14 mg/kg) administration, and alveolar fluid clearance was measured in live rats (n = 8). In primary rat ATII epithelial cells, protectin DX (3.605 × 10 -3  mg/l) was added to the culture medium with LPS for 6 h. Protectin DX improved alveolar fluid clearance (9.65 ± 1.60 vs. 15.85 ± 1.49, p < 0.0001) and decreased pulmonary edema and lung injury in LPS-induced lung injury in rats. Protectin DX markedly regulated alveolar fluid clearance by upregulating sodium channel and Na, K-ATPase protein expression levels in vivo and in vitro. Protectin DX also increased the activity of Na, K-ATPase and upregulated P-Akt via inhibiting Nedd4-2 in vivo. In addition, protectin DX enhanced the subcellular distribution of sodium channels and Na, K-ATPase, which were specifically localized to the apical and basal membranes of primary rat ATII cells. Furthermore, BOC-2, Rp-cAMP, and LY294002 blocked the increased alveolar fluid clearance in response to protectin DX. Protectin DX stimulates alveolar fluid clearance through a mechanism partly dependent on alveolar epithelial sodium channel and Na, K-ATPase activation via the ALX/PI3K/Nedd4-2 signaling pathway.

  16. Numerical investigation of hub clearance flow in a Kaplan turbine

    NASA Astrophysics Data System (ADS)

    Wu, H.; Feng, J. J.; Wu, G. K.; Luo, X. Q.

    2012-11-01

    In this paper, the flow field considering the hub clearance flow in a Kaplan turbine has been investigated through using the commercial CFD code ANSYS CFX based on high-quality structured grids generated by ANSYS ICEM CFD. The turbulence is simulated by k-ω based shear stress transport (SST) turbulence model together with automatic near wall treatments. Four kinds of simulations have been conducted for the runner geometry without hub clearance, with only the hub front clearance, with only the rear hub clearance, and with both front and rear clearance. The analysis of the obtained results is focused on the flow structure of the hub clearance flow, the effect on the turbine performance including hydraulic efficiency and cavitation performance, which can improve the understanding on the flow field in a Kaplan turbine.

  17. BAG3 facilitates the clearance of endogenous tau in primary neurons.

    PubMed

    Lei, Zhinian; Brizzee, Corey; Johnson, Gail V W

    2015-01-01

    Tau is a microtubule associated protein that is found primarily in neurons, and in pathologic conditions, such as Alzheimer's disease (AD) it accumulates and contributes to the disease process. Because tau plays a fundamental role in the pathogenesis of AD and other tauopathies, and in AD mouse models reducing tau levels improves outcomes, approaches that facilitate tau clearance are being considered as therapeutic strategies. However, fundamental to the development of such interventions is a clearer understanding of the mechanisms that regulate tau clearance. Here, we report a novel mechanism of tau degradation mediated by the co-chaperone BAG3. BAG3 has been shown to be an essential component of a complex that targets substrates to the autophagy pathway for degradation. In rat primary neurons, activation of autophagy by inhibition of proteasome activity or treatment with trehalose resulted in significant decreases in tau and phospho-tau levels. These treatments also induced an upregulation of BAG3. Proteasome inhibition activated JNK, which was responsible for the upregulation of BAG3 and increased tau clearance. Inhibiting JNK or knocking down BAG3 blocked the proteasome inhibition-induced decreases in tau. Further, BAG3 overexpression alone resulted in significant decreases in tau and phospho-tau levels in neurons. These results indicate that BAG3 plays a critical role in regulating the levels of tau in neurons, and interventions that increase BAG3 levels could provide a therapeutic approach in the treatment of AD. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Population pharmacokinetics of telapristone (CDB-4124) and its active monodemethylated metabolite CDB-4453, with a mixture model for total clearance.

    PubMed

    Morris, Denise; Podolski, Joseph; Kirsch, Alan; Wiehle, Ronald; Fleckenstein, Lawrence

    2011-12-01

    Telapristone is a selective progesterone antagonist that is being developed for the long-term treatment of symptoms associated with endometriosis and uterine fibroids. The population pharmacokinetics of telapristone (CDB-4124) and CDB-4453 was investigated using nonlinear mixed-effects modeling. Data from two clinical studies (n = 32) were included in the analysis. A two-compartment (parent) one compartment (metabolite) mixture model (with two populations for apparent clearance) with first-order absorption and elimination adequately described the pharmacokinetics of telapristone and CDB-4453. Telapristone was rapidly absorbed with an absorption rate constant (Ka) of 1.26 h(-1). Moderate renal impairment resulted in a 74% decrease in Ka. The population estimates for oral clearance (CL/F) for the two populations were 11.6 and 3.34 L/h, respectively, with 25% of the subjects being allocated to the high-clearance group. Apparent volume of distribution for the central compartment (V2/F) was 37.4 L, apparent inter-compartmental clearance (Q/F) was 21.9 L/h, and apparent peripheral volume of distribution for the parent (V4/F) was 120 L. The ratio of the fraction of telapristone converted to CDB-4453 to the distribution volume of CDB-4453 (Fmet(est)) was 0.20/L. Apparent volume of distribution of the metabolite compartment (V3/F) was fixed to 1 L and apparent clearance of the metabolite (CLM/F) was 2.43 L/h. A two-compartment parent-metabolite model adequately described the pharmacokinetics of telapristone and CDB-4453. The clearance of telapristone was separated into two populations and could be the result of metabolism via polymorphic CYP3A5.

  19. Inherited Disorders of Bilirubin Clearance

    PubMed Central

    Memon, Naureen; Weinberger, Barry I; Hegyi, Thomas; Aleksunes, Lauren M

    2016-01-01

    Inherited disorders of hyperbilirubinemia may be caused by increased bilirubin production or decreased bilirubin clearance. Reduced hepatic bilirubin clearance can be due to defective 1) unconjugated bilirubin uptake and intrahepatic storage, 2) conjugation of glucuronic acid to bilirubin (e.g. Gilbert syndrome, Crigler-Najjar syndrome, Lucey-Driscoll syndrome, breast milk jaundice), 3) bilirubin excretion into bile (Dubin-Johnson syndrome), or 4) conjugated bilirubin re-uptake (Rotor syndrome). In this review, the molecular mechanisms and clinical manifestations of these conditions are described, as well as current approaches to diagnosis and therapy. PMID:26595536

  20. Turbo machine tip clearance and vibration measurements using a fibre optic laser Doppler position sensor

    NASA Astrophysics Data System (ADS)

    Pfister, T.; Büttner, L.; Czarske, J.; Krain, H.; Schodl, R.

    2006-07-01

    This paper presents a novel fibre optic laser Doppler position sensor for single blade tip clearance and vibration measurements at turbo machines, which offers high temporal resolution and high position resolution simultaneously. The sensor principle is based on the generation of a measurement volume consisting of two superposed fan-like interference fringe systems with contrary fringe spacing gradients using wavelength division multiplexing. A flexible and robust measurement system with an all-passive fibre coupled measurement head has been realized employing diffractive and refractive optics. Measurements of tip clearance and rotor vibrations at a transonic centrifugal compressor performed during operation at up to 50 000 rpm (833 Hz) corresponding to 21.7 kHz blade frequency and 586 m s-1 blade tip velocity are presented. The results are in excellent agreement with those of capacitive probes. The mean uncertainty of the position measurement was around 20 µm and, thus, considerably better than for conventional tip clearance probes. Consequently, this sensor is capable of fulfilling the requirements for future active clearance control systems and has great potential for in situ and online tip clearance and vibration measurements at metallic and non-metallic turbine blades with high precision.

  1. Assessment of kidney function in children by enzymatic determination of 2- or 24-h creatinine clearance: comparison with inulin clearance.

    PubMed

    Uemura, Osamu; Nagai, Takuhito; Yamakawa, Satoshi; Kaneko, Tetsuji; Hibi, Yoshiko; Yamasaki, Yasuhito; Yamamoto, Masaki; Nakano, Masaru; Iwata, Naoyuki; Hibino, Satoshi

    2016-06-01

    Although renal inulin clearance (Cin) is the gold standard for evaluation of kidney function, it cannot be measured easily. Therefore, creatinine clearance (Ccr) is often used clinically to evaluate kidney function. Enzymatically measured Ccr was recently found to be much higher than Cin because of the tubular secretion of creatinine (Cr). This study compared three measures of renal clearance, inulin, 2-h Ccr, and 24-h Ccr, in children. Kidney function was evaluated in 76 children (51 males and 25 females) aged 1 month to 18 years with chronic kidney disease (CKD) by three renal clearance methods at almost the same time. Correlations between each pair of three renal clearance measurements were determined. Approximate glomerular filtration rate (GFR) was equal to 62 % of 2-h Ccr or 76 % of 24-h Ccr. Cr secretion by renal tubules was approximately 50 % of the GFR. In this study, we indicate that the measurements of 2-h Ccr or 24-h Ccr do not show true GFR but we could infer approximate GFR from the values. The use of 2- or 24-h Ccr might contribute to the treatment of pediatric CKD patients.

  2. Seasonal bat activity related to insect emergence at three temperate lakes.

    PubMed

    Salvarina, Ioanna; Gravier, Dorian; Rothhaupt, Karl-Otto

    2018-04-01

    Knowledge of aquatic food resources entering terrestrial systems is important for food web studies and conservation planning. Bats, among other terrestrial consumers, often profit from aquatic insect emergence and their activity might be closely related to such events. However, there is a lack of studies which monitor bat activity simultaneously with aquatic insect emergence, especially from lakes. Thus, our aim was to understand the relationship between insect emergence and bat activity, and investigate whether there is a general spatial or seasonal pattern at lakeshores. We assessed whole-night bat activity using acoustic monitoring and caught emerging and aerial flying insects at three different lakes through three seasons. We predicted that insect availability and seasonality explain the variation in bat activity, independent of the lake size and characteristics. Spatial (between lakes) differences of bat activity were stronger than temporal (seasonal) differences. Bat activity did not always correlate to insect emergence, probably because other factors, such as habitat characteristics, or bats' energy requirements, play an important role as well. Aerial flying insects explained bat activity better than the emerged aquatic insects in the lake with lowest insect emergence. Bats were active throughout the night with some activity peaks, and the pattern of their activity also differed among lakes and seasons. Lakes are important habitats for bats, as they support diverse bat communities and activity throughout the night and the year when bats are active. Our study highlights that there are spatial and temporal differences in bat activity and its hourly nocturnal pattern, that should be considered when investigating aquatic-terrestrial interactions or designing conservation and monitoring plans.

  3. Modified Augmented Renal Clearance Score Predicts Rapid Piperacillin and Tazobactam Clearance in Critically Ill Surgery and Trauma Patients

    DTIC Science & Technology

    2014-04-24

    intermittent dosing regimens. CONCLUSION: Given its ability to predict antimicrobial clearance above populationmedians, which could compromise therapy, the...campaign dedicated to improve out- comes.1,2 In the era ofmultiply drug- resistant pathogens and rising antimicrobial minimum inhibitory concentrations (MICs...urinary creatinine clearance significantly exceeds what is predicted by the serum creatinine concentration according to various mathematical

  4. Advanced optical blade tip clearance measurement system

    NASA Technical Reports Server (NTRS)

    Ford, M. J.; Honeycutt, R. E.; Nordlund, R. E.; Robinson, W. W.

    1978-01-01

    An advanced electro-optical system was developed to measure single blade tip clearances and average blade tip clearances between a rotor and its gas path seal in an operating gas turbine engine. This system is applicable to fan, compressor, and turbine blade tip clearance measurement requirements, and the system probe is particularly suitable for operation in the extreme turbine environment. A study of optical properties of blade tips was conducted to establish measurement system application limitations. A series of laboratory tests was conducted to determine the measurement system's operational performance characteristics and to demonstrate system capability under simulated operating gas turbine environmental conditions. Operational and environmental performance test data are presented.

  5. The "glymphatic" mechanism for solute clearance in Alzheimer's disease: game changer or unproven speculation?

    PubMed

    Smith, Alex J; Verkman, Alan S

    2018-02-01

    How solutes and macromolecules are removed from brain tissue is of central importance in normal brain physiology and in how toxic protein aggregates are cleared in neurodegenerative conditions, including Alzheimer's disease (AD). Conventionally, solute transport in the narrow and tortuous extracellular space in brain parenchyma has been thought to be primarily diffusive and nondirectional. The recently proposed "glymphatic" (glial-lymphatic) hypothesis posits that solute clearance is convective and driven by active fluid transport from para-arterial to paravenous spaces though aquaporin-4 water channels in astrocyte endfeet. Glymphatic, convective solute clearance has received much attention because of its broad implications for AD and other brain pathologies and even the function of sleep. However, the theoretical plausibility of glymphatic transport has been questioned, and recent data have challenged its experimental underpinnings. A substantiated mechanism of solute clearance in the brain is of considerable importance because of its implications for pathogenic mechanisms of neurologic diseases and delivery of therapeutics.-Smith, A. J., Verkman, A. S. The "glymphatic" mechanism for solute clearance in Alzheimer's disease: game changer or unproven speculation?

  6. 19 CFR 4.61 - Requirements for clearance.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 1 2014-04-01 2014-04-01 false Requirements for clearance. 4.61 Section 4.61 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE... made by filing Customs Form 1300 (Vessel Entrance or Clearance Statement) executed by the vessel master...

  7. 19 CFR 4.61 - Requirements for clearance.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 19 Customs Duties 1 2013-04-01 2013-04-01 false Requirements for clearance. 4.61 Section 4.61 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE... made by filing Customs Form 1300 (Vessel Entrance or Clearance Statement) executed by the vessel master...

  8. 19 CFR 4.61 - Requirements for clearance.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 19 Customs Duties 1 2012-04-01 2012-04-01 false Requirements for clearance. 4.61 Section 4.61 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE... made by filing Customs Form 1300 (Vessel Entrance or Clearance Statement) executed by the vessel master...

  9. 19 CFR 4.61 - Requirements for clearance.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 19 Customs Duties 1 2011-04-01 2011-04-01 false Requirements for clearance. 4.61 Section 4.61 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE... made by filing Customs Form 1300 (Vessel Entrance or Clearance Statement) executed by the vessel master...

  10. 75 FR 52803 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-27

    ... intention to request the Office of Management and Budget (OMB) approval to renew an information collection..., 2010. Carla Scott, FAA Information Collection Clearance Officer, IT Enterprises Business Services... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection...

  11. Clearance of amyloid-β peptide across the choroid plexus in Alzheimer's disease.

    PubMed

    Alvira-Botero, Ximena; Carro, Eva M

    2010-12-01

    Aging and several neurodegenerative diseases bring about changes in the anatomy and physiology of the choroid plexus. The identification of specific membrane receptors that bind and internalize extracellular ligands has revolutionized the traditional roles of this tissue. Amyloid beta peptide (Aβ), the major constituent of the amyloid core of senile plaques in patients with Alzheimer's disease (AD) is known to contribute to disease neuropathology and progression. Recent emphasis on comorbidity of AD and a deficient clearance of Aβ across the blood-brain barrier and blood-cerebrospinal fluid barrier have highlighted the importance of brain Aβ clearance in AD. The megalin receptor has also been implicated in the pathogenesis of AD. Faulty Aβ clearance from the brain across the choroid plexus epithelium by megalin appears to mediate focal Aβ accumulation in AD. Patients with AD have reduced levels of megalin at the choroid plexus, which in turn seem to increase brain levels of Aβ through a decreased efflux of brain Aβ. Therapies that increase megalin expression at the choroid plexus could potentially control accumulation of brain Aβ. This review covers in depth the anatomy and function of the choroid plexus, focusing on the brain barrier at the choroid plexus, as it actively participates in Aβ clearance. In addition, we describe the role of the choroid plexus in brain functions, aging and AD, as well as the role of megalin in the process of Aβ clearance. Finally, we present current data on the use of choroid plexus cells to repair the damaged brain.

  12. Early lactate clearance is associated with biomarkers of inflammation, coagulation, apoptosis, organ dysfunction and mortality in severe sepsis and septic shock

    PubMed Central

    2010-01-01

    Background Lactate clearance, a surrogate for the magnitude and duration of global tissue hypoxia, is used diagnostically, therapeutically and prognostically. This study examined the association of early lactate clearance with selected inflammatory, coagulation, apoptosis response biomarkers and organ dysfunction scores in severe sepsis and septic shock. Methods Measurements of serum arterial lactate, biomarkers (interleukin-1 receptor antagonist, interleukin-6, interleukin-8, interleukin-10, tumor necrosis factor-alpha, intercellular adhesion molecule-1, high mobility group box-1, D-Dimer and caspase-3), and organ dysfunction scores (Acute Physiology and Chronic Health Evaluation II, Simplified Acute Physiology Score II, Multiple Organ Dysfunction Score, and Sequential Organ Failure Assessment) were obtained in conjunction with a prospective, randomized study examining early goal-directed therapy in severe sepsis and septic shock patients presenting to the emergency department (ED). Lactate clearance was defined as the percent change in lactate levels after six hours from a baseline measurement in the ED. Results Two-hundred and twenty patients, age 65.0 +/- 17.1 years, were examined, with an overall lactate clearance of 35.5 +/- 43.1% and in-hospital mortality rate of 35.0%. Patients were divided into four quartiles of lactate clearance, -24.3 +/- 42.3, 30.1 +/- 7.5, 53.4 +/- 6.6, and 75.1 +/- 7.1%, respectively (p < 0.01). The mean levels of all biomarkers and organ dysfunction scores over 72 hours were significantly lower with higher lactate clearance quartiles (p < 0.01). There was a significant decreased in-hospital, 28-day, and 60-day mortality in the higher lactate clearance quartiles (p < 0.01). Conclusions Early lactate clearance as a surrogate for the resolution of global tissue hypoxia is significantly associated with decreased levels of biomarkers, improvement in organ dysfunction and outcome in severe sepsis and septic shock. PMID:20181046

  13. 75 FR 57828 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-22

    ... intention to request the Office of Management and Budget (OMB) approval to renew an information collection... 15, 2010. Carla Scott, FAA Information Collection Clearance Officer, IT Enterprises Business Services... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Agency Information Collection...

  14. Adequacy of peritoneal dialysis: beyond small solute clearance.

    PubMed

    Goldberg, Ryan; Yalavarthy, Rajesh; Teitelbaum, Isaac

    2009-01-01

    Peritoneal dialysis adequacy is monitored primarily by indices of small solute clearance, Kt/V(urea) and creatinine clearance (C(cr)). Once a threshold of adequacy has been obtained, however, increasing small solute clearance does not result in improved long-term outcomes of PD patients. There are several other factors that may affect optimal dialysis outcomes. These include, but are not limited to: ultrafiltration, inflammation, malnutrition, and mineral metabolism. In this article, we will briefly review data regarding the relationships between these factors and survival on PD.

  15. The tear turnover and tear clearance tests - a review.

    PubMed

    Garaszczuk, Izabela K; Montes Mico, Robert; Iskander, D Robert; Expósito, Alejandro Cerviño

    2018-03-01

    The aim is to provide a summary of methods available for the assessment of tear turnover and tear clearance rates. The review defines tear clearance and tear turnover and describes their implication for ocular surface health. Additionally, it describes main types of techniques for measuring tear turnover, including fluorescein tear clearance tests, techniques utilizing electromagnetic spectrum and tracer molecule and novel experimental techniques utilizing optical coherence tomography and fluorescein profilometry. Areas covered: Internet databases (PubMed, Science Direct, Google Scholar) and most frequently cited references were used as a principal resource of information on tear turnover rate and tear clearance rate, presenting methodologies and equipment, as well as their definition and implications for the anterior eye surface health and function. Keywords used for data-search were as follows: tear turnover, tear clearance, fluorescein clearance, scintigraphy, fluorophotometry, tear flow, drainage, tear meniscus dynamics, Krehbiel flow and lacrimal functional unit. Expert commentary: After decades, the topic of tear turnover assessment has been reintroduced. Recently, new techniques have been developed to propose less invasive, less time consuming and simpler methodologies for the assessment of tear dynamics that have the potential to be utilized in clinical practice.

  16. Oscillations In Emerging Active Regions on the Sun

    NASA Astrophysics Data System (ADS)

    Garcia, M. A.; Muglach, K.

    2017-12-01

    Active regions (ARs) on the Sun are directly related to space weather phenomena like flares and coronal mass ejections (CMEs). It is well known that both can have impacts not only on Earth, but also on nearby orbits and beyond. Predicting when and where active regions will emerge at the surface of the Sun would strengthen space weather forecasting abilities. In this study, data from the Solar Dynamics Observatory (SDO) are used to produce images of the magnetic field and Doppler Velocity at the photosphere of the Sun. This data is used to study the emergence of ARs at the surface of the Sun. Since global oscillations that travel through the solar interior are modified by the magnetic field, the oscillation patterns in and around ARs should be different from the oscillation patterns in the quiet, non-active Sun. Thus, a change in oscillation patterns can be determined before an AR is visible at the Sun's surface. Using Fast Fourier Transforms, the oscillation patterns can be calculated from the SDO Dopplergrams. Magnetograms provide the time when the magnetic field of the active region reaches the solar surface. Thus, both the calculated oscillation frequencies and power can be compared to the information of an AR's emergence in the magnetograms. In particular, it can be determined if there is any time delay between the change of oscillation power and magnetic field emergence. For this particular AR studied, it was found that the 5-min oscillation power starts to decrease at the time the AR emerges. The 3-min oscillation power also decreases first but increases again a few hours after the start of the emergence. This observation is probably due to 3-min oscillation power halos around the AR and has been observed before. A few hours before the AR starts to emerge, an increase was found in both 5-min and 3-min oscillation power. This effect is promising, however, it has not been observed before and has to be verified with additional observations.

  17. Lactate clearance as a marker of mortality in pediatric intensive care unit.

    PubMed

    Munde, A; Kumar, N; Beri, R S; Puliyel, J M

    2014-07-01

    To correlate lactate clearance with Pediatric Intensive Care Unit (PICU) mortality. 45 (mean age 40.15 mo, 60% males) consecutive admissions in the PICU were enrolled between May 2012 to June 2013. Lactate clearance (Lactate level at admission - level 6 hr later x 100 / lactate level at admission) in first 6 hours of hospitalization was correlated to in-hospital mortality and PRISM score. Twelve out of 45 patients died. 90% died among those with delayed/poor clearance (clearance <30%) compared to 8.5% in those with good clearance (clearance >30%) (P<0.001). Lactate clearance <30% predicted mortality with sensitivity of 75%, specificity of 97%, positive predictive value of 90%, and negative predictive value of 91.42%. Predictability was comparable to PRISM score >30. Lactate clearance at six hours correlates with mortality in the PICU.

  18. Designing a Quantitative Structure-Activity Relationship for the Intrinsic Metabolic Clearance of Environmentally Relevant Chemicals

    EPA Science Inventory

    Toxicokinetic models serve a vital role in risk assessment by bridging the gap between chemical exposure and potentially toxic endpoints. While intrinsic metabolic clearance rates have a strong impact on toxicokinetics, limited data is available for environmentally relevant chemi...

  19. 75 FR 65340 - Agency Emergency Information Collection Clearance Request for Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-22

    .... Proposed Project: Healthy Living Innovation Awards--OMB No. 0990- NEW--Emergency Information Collection... Secretary for Planning and Evaluation (ASPE) is requesting emergency approval from the Office of Management... Living Innovation Awards. The project will provide an opportunity for HHS to increase public awareness of...

  20. 46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... worn down to 6.4 mm (0.25 in) clearance for shafts of 229 mm (9 in) or less in diameter, 7.95 mm (0.3125 in) clearance for shafts exceeding 229 mm (9 in) but not exceeding 305 mm (12 in) in diameter, and 9.53 mm (0.375 in) clearance for shafts exceeding 305 mm (12 in) in diameter. (2) Where the...

  1. 46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... worn down to 6.4 mm (0.25 in) clearance for shafts of 229 mm (9 in) or less in diameter, 7.95 mm (0.3125 in) clearance for shafts exceeding 229 mm (9 in) but not exceeding 305 mm (12 in) in diameter, and 9.53 mm (0.375 in) clearance for shafts exceeding 305 mm (12 in) in diameter. (2) Where the...

  2. 46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... worn down to 6.4 mm (0.25 in) clearance for shafts of 229 mm (9 in) or less in diameter, 7.95 mm (0.3125 in) clearance for shafts exceeding 229 mm (9 in) but not exceeding 305 mm (12 in) in diameter, and 9.53 mm (0.375 in) clearance for shafts exceeding 305 mm (12 in) in diameter. (2) Where the...

  3. 46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... worn down to 6.4 mm (0.25 in) clearance for shafts of 229 mm (9 in) or less in diameter, 7.95 mm (0.3125 in) clearance for shafts exceeding 229 mm (9 in) but not exceeding 305 mm (12 in) in diameter, and 9.53 mm (0.375 in) clearance for shafts exceeding 305 mm (12 in) in diameter. (2) Where the...

  4. 46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... worn down to 6.4 mm (0.25 in) clearance for shafts of 229 mm (9 in) or less in diameter, 7.95 mm (0.3125 in) clearance for shafts exceeding 229 mm (9 in) but not exceeding 305 mm (12 in) in diameter, and 9.53 mm (0.375 in) clearance for shafts exceeding 305 mm (12 in) in diameter. (2) Where the...

  5. Trends in emerging and high risk activities

    Treesearch

    Robert C. White; Richard Schreyer; Kent Downing

    1980-01-01

    Newly emerging and high risk activities have increased markedly in the last generation, yet little is known about trends in participation. Factors such as technological innovation and creative experimentation with traditional activities appear to play a major role in the development of new activities. Christy's criteria for mass demand in recreation are used to...

  6. 77 FR 11164 - Agency Information Collection Activities: Emergency Clearance Submission for the Office of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-24

    ... seven public meetings to gather stakeholder feedback. Further, the Nuclear Energy Institute provided... NUCLEAR REGULATORY COMMISSION [Docket No. NRC-2012-0047] Agency Information Collection Activities...: Nuclear Regulatory Commission. ACTION: Notice of pending NRC action to submit an information collection...

  7. 78 FR 48542 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-08

    ... professional and personal qualifications. The FAA uses the information provided to screen and select designees... professional and personal qualifications. Respondents: Approximately 5,015 applicants annually. Frequency... Washington, DC on August 2, 2013. Albert R. Spence, FAA Assistant Information Collection Clearance Officer...

  8. Duration and clearance of anal human papillomavirus (HPV) infection among women: the Hawaii HPV cohort study.

    PubMed

    Shvetsov, Yurii B; Hernandez, Brenda Y; McDuffie, Katharine; Wilkens, Lynne R; Zhu, Xuemei; Ning, Lily; Killeen, Jeffrey; Kamemoto, Lori; Goodman, Marc T

    2009-03-01

    The association of anal cancer with human papillomavirus (HPV) infection is well established; however, little is known about the epidemiology of anal HPV in healthy women. We investigated patterns of duration and clearance of anal HPV infection in a cohort of healthy women in Hawaii. Viral and nonviral determinants of anal HPV clearance were examined in a longitudinal cohort study of 431 sexually active women. At baseline and at 4-month intervals, interviews were conducted and cervical and anal cell specimens were obtained for detection of HPV DNA. Of the 431 women, 50% experienced a total of 414 incident anal HPV infections, reported at 1 clinic visits from baseline through a follow-up period of average duration of 1.2 years. Of these infections, 58% cleared during follow-up. The clearance rate for a high-risk anal infection was 9.2 per 100 woman-months (95% confidence interval [CI], 6.9-11.9 per 100 woman-months), with a median duration of 150 days (95% CI, 132-243 days). The slowest clearing high-risk HPV types were HPV-59 (median clearance time, 350 days) and HPV-58 (median clearance time, 252 days). The median clearance times for HPV-16 and HPV-18, the predominant types associated with anal cancer, were 132 days and 212 days, respectively. Nonviral factors that delayed clearance of anal HPV included douching, long-term tobacco smoking, and anal sex. The majority of anal HPV infections resolve in a relatively short time. Although anal HPV is commonly acquired in healthy women, its rapid clearance suggests limited efficacy of HPV testing as an anal cancer screening tool.

  9. Failure to activate the in-hospital emergency team: causes and outcomes.

    PubMed

    Barbosa, Vera; Gomes, Ernestina; Vaz, Senio; Azevedo, Gustavo; Fernandes, Gonçalo; Ferreira, Amélia; Araujo, Rui

    2016-01-01

    To determine the incidence of afferent limb failure of the in-hospital Medical Emergency Team, characterizing it and comparing the mortality between the population experiencing afferent limb failure and the population not experiencing afferent limb failure. A total of 478 activations of the Medical Emergency Team of Hospital Pedro Hispano occurred from January 2013 to July 2015. A sample of 285 activations was obtained after excluding incomplete records and activations for patients with less than 6 hours of hospitalization. The sample was divided into two groups: the group experiencing afferent limb failure and the group not experiencing afferent limb failure of the Medical Emergency Team. Both populations were characterized and compared. Statistical significance was set at p ≤ 0.05. Afferent limb failure was observed in 22.1% of activations. The causal analysis revealed significant differences in Medical Emergency Team activation criteria (p = 0.003) in the group experiencing afferent limb failure, with higher rates of Medical Emergency Team activation for cardiac arrest and cardiovascular dysfunction. Regarding patient outcomes, the group experiencing afferent limb failure had higher immediate mortality rates and higher mortality rates at hospital discharge, with no significant differences. No significant differences were found for the other parameters. The incidence of cardiac arrest and the mortality rate were higher in patients experiencing failure of the afferent limb of the Medical Emergency Team. This study highlights the need for health units to invest in the training of all healthcare professionals regarding the Medical Emergency Team activation criteria and emergency medical response system operations.

  10. The role of lectins and glycans in platelet clearance

    PubMed Central

    Hoffmeister, Karin M.

    2015-01-01

    Summary In recent years, it has become increasingly apparent that the life span of transfused platelets in circulation is regulated, at least in part, by glycan-lectin mediated mechanisms. There is clear evidence that refrigerated platelets are cleared by glycan-lectin mediated clearance mechanisms. Acute platelet cooling clusters glycoprotein (GP) Ibα receptors bearing uncovered N-acetylglucosamine (GlcNAc), and αMβ2 integrins on hepatic macrophages recognise clustered GlcNAc to rapidly clear these platelets from circulation. With prolonged refrigeration GPIbα clustering bearing uncovered galactose increases, which mediates the removal of long-term refrigerated platelets via hepatic Ashwell-Morell receptors (AMR), originally named as asialoglycoprotein receptors. In contrast, little is known about the molecular mechanisms of transfused room temperature platelet clearance. This review examines the role of glycan-lectin mediated clearance of exogenous, i.e. transfused chilled platelet clearance and briefly addresses the current knowledge of stored platelet function, degradation and its relation to platelet clearance. PMID:21781240

  11. The Immune Response in Measles: Virus Control, Clearance and Protective Immunity.

    PubMed

    Griffin, Diane E

    2016-10-12

    Measles is an acute systemic viral infection with immune system interactions that play essential roles in multiple stages of infection and disease. Measles virus (MeV) infection does not induce type 1 interferons, but leads to production of cytokines and chemokines associated with nuclear factor kappa-light-chain-enhancer of activated B cells (NFκB) signaling and activation of the NACHT, LRR and PYD domains-containing protein (NLRP3) inflammasome. This restricted response allows extensive virus replication and spread during a clinically silent latent period of 10-14 days. The first appearance of the disease is a 2-3 day prodrome of fever, runny nose, cough, and conjunctivitis that is followed by a characteristic maculopapular rash that spreads from the face and trunk to the extremities. The rash is a manifestation of the MeV-specific type 1 CD4⁺ and CD8⁺ T cell adaptive immune response with lymphocyte infiltration into tissue sites of MeV replication and coincides with clearance of infectious virus. However, clearance of viral RNA from blood and tissues occurs over weeks to months after resolution of the rash and is associated with a period of immunosuppression. However, during viral RNA clearance, MeV-specific antibody also matures in type and avidity and T cell functions evolve from type 1 to type 2 and 17 responses that promote B cell development. Recovery is associated with sustained levels of neutralizing antibody and life-long protective immunity.

  12. Automation for "Direct-to" Clearances in Air-Traffic Control

    NASA Technical Reports Server (NTRS)

    Erzberger, Heinz; McNally, David

    2006-01-01

    A method of automation, and a system of computer hardware and software to implement the method, have been invented to assist en-route air-traffic controllers in the issuance of clearances to fly directly to specified waypoints or navigation fixes along straight paths that deviate from previously filed flight plans. Such clearances, called "direct-to" clearances, have been in use since before the invention of this method and system.

  13. Clearance of psoriasis: the impact of private versus public insurance.

    PubMed

    Buzney, Catherine D; Peterman, Caitlin; Saraiya, Ami; Au, Shiu-chung; Dumont, Nicole; Mansfield, Ryan; Gottlieb, Alice B

    2015-02-01

    Psoriasis treatments and therapeutic response as they relate to private versus public patient insurance in the United States have not yet been reviewed. Improved understanding could clarify factors challenging optimal psoriasis management and offer insight for dermatologists treating psoriasis within our healthcare system. 258 subjects were included from a database of psoriasis patients seen at Tufts Medical Center (Boston, MA) during 2008-2014. Insurance was classified as primarily private or public (Medicare or MassHealth/Medicaid). Patients required a minimum of two consecutive visits per treatment and at least 8 weeks within one of four treatment categories: biologics, oral systemics/ phototherapy, combined biologics and oral systemics/phototherapy, or topicals only. Primary endpoint was the Simple-Measure for Assessing Psoriasis Activity (S-MAPA) calculated by multiplying Physician Global Assessment by Body Surface Area. S-MAPA<3 constituted absolute clearance. Insurance type was evaluated as a predictor of prescribed treatment categories, maximum S-MAPA improvement from baseline, and total drugs used per treatment course (“drug-switching”). 80.2% (n=207) and 19.8% (n=51) had primarily private and public insurance, respectively. 69.6% with private insurance were prescribed biologics versus 66.7% (public insurance) (P=0.689). 54% (private) versus 49% (public) achieved clearance (P=0.514). However, S-MAPA decreased 78.35% from baseline in those with private insurance compared to 61.48% (public) (P=0.036). On average, privately insured patients used at least twice as many same-category treatments, most commonly biologics, than publicly insured individuals (P=0.003). Drug-switching was significantly associated with clearance (P=0.024). Multivariate analysis demonstrated no significant differences in prescribed treatment categories, drug efficacy, clearance, S-MAPA, or drugswitching with respect to patient age. Treatment categories were comparably prescribed

  14. Lung clearance of /sup 99m/Tc-DTPA in patients with acute lung injury and pulmonary edema

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coates, G.; O'Brodovich, H.; Dolovich, M.

    1988-07-01

    Several acute and chronic conditions that alter the integrity of the pulmonary epithelium increased the rate of absorption or clearance into the circulation of small solutes deposited in the alveoli. Technetium 99m diethylenetriamine pentaacetic acid can be deposited in the lungs as a submicronic aerosol and its rate of clearance measured with a gamma camera or simple probe. This clearance technique is currently being used to evaluate patients who have developed pulmonary edema and also to detect those patients from a high risk group who are likely to develop adult respiratory distress syndrome (ARDS). Its role in the evaluation ofmore » patients with pulmonary edema is still under active investigation. It is clear that a single measurement in patients who smoke is not useful, but repeated measurements may provide important information. The lung clearance measurement is very sensitive to changes in epithelial integrity but is not specific for ARDS. It may be most useful in combination with other predictive tests or when the clearance rate is normal. 54 references.« less

  15. SIGN-R1 and complement factors are involved in the systemic clearance of radiation-induced apoptotic cells in whole-body irradiated mice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Jin-Yeon; Loh, SoHee; Cho, Eun-hee

    Although SIGN-R1-mediated complement activation pathway has been shown to enhance the systemic clearance of apoptotic cells, the role of SIGN-R1 in the clearance of radiation-induced apoptotic cells has not been characterized and was investigated in this study. Our data indicated that whole-body γ-irradiation of mice increased caspase-3{sup +} apoptotic lymphocyte numbers in secondary lymphoid organs. Following γ-irradiation, SIGN-R1 and complements (C4 and C3) were simultaneously increased only in the mice spleen tissue among the assessed tissues. In particular, C3 was exclusively activated in the spleen. The delayed clearance of apoptotic cells was markedly prevalent in the spleen and liver ofmore » SIGN-R1 KO mice, followed by a significant increase of CD11b{sup +} cells. These results indicate that SIGN-R1 and complement factors play an important role in the systemic clearance of radiation-induced apoptotic innate immune cells to maintain tissue homeostasis after γ-irradiation. - Highlights: • Splenic SIGN-R1{sup +} macrophages are activated after γ-irradiation. • C3 and C4 levels increased and C3 was activated in the spleen after γ-irradiation. • SIGN-R1 mediated the systemic clearance of radiation-induced apoptotic cells in spleen and liver.« less

  16. 76 FR 13265 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-10

    ... Administration, IT Enterprises Business Services Division, AES-200, 800 Independence Ave., SW., Washington, DC.... Carla Scott, FAA Information Collection Clearance Officer, IT Enterprises Business Services Division... invites public comments about our intention to request the Office of Management and Budget (OMB) approval...

  17. Long-term clearance from small airways in patients with cystic fibrosis.

    PubMed

    Lindström, M; Camner, P; Falk, R; Hjelte, L; Philipson, K; Svartengren, M

    2005-02-01

    Impaired mucociliary clearance is a hallmark of cystic fibrosis (CF). Early morphological changes first appear in the small airways. Lung clearance was investigated in 11 young CF adults with mild-to-moderate lung disease using a method depositing particles mainly in the small airways. Radiolabelled Teflon particles (6 microm) were inhaled with an extremely slow inhalation flow, 0.05 L x s(-1). Lung retention was measured immediately following inhalations and, on four occasions up to 21 days. The results were compared with data from healthy subjects. The lung retention at 24 h in % of deposition was 67% (95% confidence interval 58-76) in the CF patients, compared to 48% (42-53) in the healthy subjects. Clearance on days 1-7 was larger in the CF patients, 22% (15-29) compared to the healthy subjects, 14% (12-16). No difference was observed between the CF patients and the healthy subjects in the slow clearance phase at day 7 to day 21, representing small airway clearance. Impaired mucociliary clearance in CF patients results in increased 24-h retention and a prolonged rapid clearance phase. The results of the study do not support the current authors' hypothesis that clearance from small airways is slower in cystic fibrosis patients compared to healthy subjects. Furthermore, the data suggest that mucociliary transport is not the dominant clearance mechanism in small airways.

  18. Circulating osteocrin stimulates bone growth by limiting C-type natriuretic peptide clearance.

    PubMed

    Kanai, Yugo; Yasoda, Akihiro; Mori, Keita P; Watanabe-Takano, Haruko; Nagai-Okatani, Chiaki; Yamashita, Yui; Hirota, Keisho; Ueda, Yohei; Yamauchi, Ichiro; Kondo, Eri; Yamanaka, Shigeki; Sakane, Yoriko; Nakao, Kazumasa; Fujii, Toshihito; Yokoi, Hideki; Minamino, Naoto; Mukoyama, Masashi; Mochizuki, Naoki; Inagaki, Nobuya

    2017-11-01

    Although peptides are safe and useful as therapeutics, they are often easily degraded or metabolized. Dampening the clearance system for peptide ligands is a promising strategy for increasing the efficacy of peptide therapies. Natriuretic peptide receptor B (NPR-B) and its naturally occurring ligand, C-type natriuretic peptide (CNP), are potent stimulators of endochondral bone growth, and activating the CNP/NPR-B system is expected to be a powerful strategy for treating impaired skeletal growth. CNP is cleared by natriuretic peptide clearance receptor (NPR-C); therefore, we investigated the effect of reducing the rate of CNP clearance on skeletal growth by limiting the interaction between CNP and NPR-C. Specifically, we generated transgenic mice with increased circulating levels of osteocrin (OSTN) protein, a natural NPR-C ligand without natriuretic activity, and observed a dose-dependent skeletal overgrowth phenotype in these animals. Skeletal overgrowth in OSTN-transgenic mice was diminished in either CNP- or NPR-C-depleted backgrounds, confirming that CNP and NPR-C are indispensable for the bone growth-stimulating effect of OSTN. Interestingly, double-transgenic mice of CNP and OSTN had even higher levels of circulating CNP and additional increases in bone length, as compared with mice with elevated CNP alone. Together, these results support OSTN administration as an adjuvant agent for CNP therapy and provide a potential therapeutic approach for diseases with impaired skeletal growth.

  19. [Manual airway clearance techniques in adults and adolescents: What level of evidence?

    PubMed

    Cabillic, Michel; Gouilly, Pascal; Reychler, Gregory

    2016-04-13

    The aim of this systematic literature review was to grade the levels of evidence of the most widely used manual airway clearance techniques. A literature search was conducted over the period 1995-2014 from the Medline, PEDro, ScienceDirect, Cochrane Library, REEDOC and kinedoc databases, with the following keywords: "postural drainage", "manual vibrations", "manual chest percussion", "directed cough", "increased expiratory flow", "ELTGOL", "autogenic drainage" and "active cycle of breathing technique". Two-hundred and fifty-six articles were identified. After removing duplicates and reading the titles and abstracts, 63 articles were selected, including 9 systematic reviews. This work highlights the lack of useful scientific data and the difficulty of determining levels of evidence for manual airway clearance techniques. Techniques were assessed principally with patients with sputum production (cystic fibrosis, DDB, COPD, etc.). It also shows the limited pertinence of outcome measures to quantify congestion and hence the efficacy of airway clearance techniques. The 1994 consensus conference summary table classifying airway clearance techniques according to physical mechanism provides an interesting tool for assessment, grouping together techniques having identical mechanisms of action. From the findings of the present systematic review, it appears that only ELTGOL, autogenic drainage and ACBT present levels of evidence "B". All other techniques have lower levels of evidence. II. Copyright © 2016. Published by Elsevier Masson SAS.

  20. A Single Mutation in K13 Predominates in Southern China and Is Associated With Delayed Clearance of Plasmodium falciparum Following Artemisinin Treatment.

    PubMed

    Huang, Fang; Takala-Harrison, Shannon; Jacob, Christopher G; Liu, Hui; Sun, Xiaodong; Yang, Henglin; Nyunt, Myaing M; Adams, Matthew; Zhou, Shuisen; Xia, Zhigui; Ringwald, Pascal; Bustos, Maria Dorina; Tang, Linhua; Plowe, Christopher V

    2015-11-15

    Artemisinin resistance in Plasmodium falciparum has emerged in Southeast Asia and poses a threat to malaria control and elimination. Mutations in a P. falciparum gene encoding a kelch protein on chromosome 13 have been associated with delayed parasite clearance following artemisinin treatment elsewhere in the region, but not yet in China. Therapeutic efficacy studies of artesunate and dihydroartemisinin-piperaquine were conducted from 2009 to 2012 in the Yunnan Province of China near the border with Myanmar. K13 mutations were genotyped by capillary sequencing of DNA extracted from dried blood spots collected in these clinical trials and in routine surveillance. Associations between K13 mutations and delayed parasite clearance were tested using regression models. Parasite clearance half-lives were prolonged after artemisinin treatment, with 44% of infections having half-lives >5 hours (n = 109). Fourteen mutations in K13 were observed, with an overall prevalence of 47.7% (n = 329). A single mutation, F446I, predominated, with a prevalence of 36.5%. Infections with F446I were significantly associated with parasitemia on day 3 following artemisinin treatment and with longer clearance half-lives. Plasmodium falciparum infections in southern China displayed markedly delayed clearance following artemisinin treatment. F446I was the predominant K13 mutation and was associated with delayed parasite clearance. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  1. Clearance detector and method for motion and distance

    DOEpatents

    Xavier, Patrick G [Albuquerque, NM

    2011-08-09

    A method for correct and efficient detection of clearances between three-dimensional bodies in computer-based simulations, where one or both of the volumes is subject to translation and/or rotations. The method conservatively determines of the size of such clearances and whether there is a collision between the bodies. Given two bodies, each of which is undergoing separate motions, the method utilizes bounding-volume hierarchy representations for the two bodies and, mappings and inverse mappings for the motions of the two bodies. The method uses the representations, mappings and direction vectors to determine the directionally furthest locations of points on the convex hulls of the volumes virtually swept by the bodies and hence the clearance between the bodies, without having to calculate the convex hulls of the bodies. The method includes clearance detection for bodies comprising convex geometrical primitives and more specific techniques for bodies comprising convex polyhedra.

  2. Effects of block copolymer properties on nanocarrier protection from in vivo clearance

    PubMed Central

    D’Addio, Suzanne M.; Saad, Walid; Ansell, Steven M.; Squiers, John J.; Adamson, Douglas; Herrera-Alonso, Margarita; Wohl, Adam R.; Hoye, Thomas R.; Macosko, Christopher W.; Mayer, Lawrence D.; Vauthier, Christine; Prud’homme, Robert K.

    2012-01-01

    Drug nanocarrier clearance by the immune system must be minimized to achieve targeted delivery to pathological tissues. There is considerable interest in finding in vitro tests that can predict in vivo clearance outcomes. In this work, we produce nanocarriers with dense PEG layers resulting from block copolymer-directed assembly during rapid precipitation. Nanocarriers are formed using block copolymers with hydrophobic blocks of polystyrene (PS), poly-ε-caprolactone (PCL), poly-D,L-lactide (PLA), or poly-lactide-co-glycolide (PLGA), and hydrophilic blocks of polyethylene glycol (PEG) with molecular weights from 1.5 kg/mol to 9 kg/mol. Nanocarriers with paclitaxel prodrugs are evaluated in vivo in Foxn1nu mice to determine relative rates of clearance. The amount of nanocarrier in circulation after 4 h varies from 10% to 85% of initial dose, depending on the block copolymer. In vitro complement activation assays are conducted in an effort to correlate the protection of the nanocarrier surface from complement binding and activation and in vivo circulation. Guidelines for optimizing block copolymer structure to maximize circulation of nanocarriers formed by rapid precipitation and directed assembly are proposed, relating to the relative size of the hydrophilic and hydrophobic block, the hydrophobicity of the anchoring block, the absolute size of the PEG block, and polymer crystallinity. The in vitro results distinguish between the poorly circulating PEG5k-PCL9k and the better circulating nanocarriers, but could not rank the better circulating nanocarriers in order of circulation time. Analysis of PEG surface packing on monodisperse 200 nm latex spheres indicates that the sizes of the hydrophobic PCL, PS, and PLA blocks are correlated with the PEG blob size, and possibly the clearance from circulation. Suggestions for next step in vitro measurements are made. PMID:22732478

  3. Methylphenidate Actively Induces Emergence from General Anesthesia

    PubMed Central

    Solt, Ken; Cotten, Joseph F.; Cimenser, Aylin; Wong, Kin F.K.; Chemali, Jessica J.; Brown, Emery N.

    2011-01-01

    Background Although accumulating evidence suggests that arousal pathways in the brain play important roles in emergence from general anesthesia, the roles of monoaminergic arousal circuits are unclear. In this study we tested the hypothesis that methylphenidate (an inhibitor of dopamine and norepinephrine transporters) induces emergence from isoflurane anesthesia. Methods Using adult rats we tested the effect of methylphenidate IV on time to emergence from isoflurane anesthesia. We then performed experiments to test separately for methylphenidate-induced changes in arousal and changes in minute ventilation. A dose-response study was performed to test for methylphenidate–induced restoration of righting during continuous isoflurane anesthesia. Surface electroencephalogram recordings were performed to observe neurophysiological changes. Plethysmography recordings and arterial blood gas analysis were performed to assess methylphenidate-induced changes in respiratory function. Droperidol IV was administered to test for inhibition of methylphenidate's actions. Results Methylphenidate decreased median time to emergence from 280 to 91 s. The median difference in time to emergence without compared to with methylphenidate was 200 [155, 331] s (median, [95% confidence interval]). During continuous inhalation of isoflurane, methylphenidate induced return of righting in a dose-dependent manner, induced a shift in electroencephalogram power from delta to theta, and induced an increase in minute ventilation. Administration of droperidol (0.5 mg/kg IV) prior to methylphenidate (5 mg/kg IV) largely inhibited methylphenidate-induced emergence behavior, electroencephalogram changes, and changes in minute ventilation. Conclusions Methylphenidate actively induces emergence from isoflurane anesthesia by increasing arousal and respiratory drive, possibly through activation of dopaminergic and adrenergic arousal circuits. Our findings suggest that methylphenidate may be clinically

  4. 2015 Annual Report on Security Clearance Determinations

    DTIC Science & Technology

    2016-06-28

    completed or pending security clearance determinations for government employees and contractors during the preceding fiscal year that have taken longer...each level during the preceding fiscal year. Similar data pertaining to USG contractors is also required. Also, for each element of the Intelligence...for USG Employees and USG Contractors Security Clearance Determination Processing Metrics for the Seven IC Agencies The number of individuals

  5. Dynamic modelling and experimental study of cantilever beam with clearance

    NASA Astrophysics Data System (ADS)

    Li, B.; Jin, W.; Han, L.; He, Z.

    2012-05-01

    Clearances occur in almost all mechanical systems, typically such as the clearance between slide plate of gun barrel and guide. Therefore, to study the clearances of mechanisms can be very important to increase the working performance and lifetime of mechanisms. In this paper, rigid dynamic modelling of cantilever with clearance was done according to the subject investigated. In the rigid dynamic modelling, clearance is equivalent to the spring-dashpot model, the impact of beam and boundary face was also taken into consideration. In ADAMS software, the dynamic simulation was carried out according to the model above. The software simulated the movement of cantilever with clearance under external excitation. Research found: When the clearance is larger, the force of impact will become larger. In order to study how the stiffness of the cantilever's supporting part influences natural frequency of the system, A Euler beam which is restricted by a draught spring and a torsion spring at its end was raised. Through numerical calculation, the relationship between natural frequency and stiffness was found. When the value of the stiffness is close to the limit value, the corresponding boundary condition is illustrated. An ADAMS experiment was carried out to check the theory and the simulation.

  6. Adiponectin modulates inflammatory reactions via calreticulin receptor–dependent clearance of early apoptotic bodies

    PubMed Central

    Takemura, Yukihiro; Ouchi, Noriyuki; Shibata, Rei; Aprahamian, Tamar; Kirber, Michael T.; Summer, Ross S.; Kihara, Shinji; Walsh, Kenneth

    2007-01-01

    Obesity and type 2 diabetes are associated with chronic inflammation. Adiponectin is an adipocyte-derived hormone with antidiabetic and antiinflammatory actions. Here, we demonstrate what we believe to be a previously undocumented activity of adiponectin, facilitating the uptake of early apoptotic cells by macrophages, an essential feature of immune system function. Adiponectin-deficient (APN-KO) mice were impaired in their ability to clear apoptotic thymocytes in response to dexamethasone treatment, and these animals displayed a reduced ability to clear early apoptotic cells that were injected into their intraperitoneal cavities. Conversely, adiponectin administration promoted the clearance of apoptotic cells by macrophages in both APN-KO and wild-type mice. Adiponectin overexpression also promoted apoptotic cell clearance and reduced features of autoimmunity in lpr mice whereas adiponectin deficiency in lpr mice led to a further reduction in apoptotic cell clearance, which was accompanied by exacerbated systemic inflammation. Adiponectin was capable of opsonizing apoptotic cells, and phagocytosis of cell corpses was mediated by the binding of adiponectin to calreticulin on the macrophage cell surface. We propose that adiponectin protects the organism from systemic inflammation by promoting the clearance of early apoptotic cells by macrophages through a receptor-dependent pathway involving calreticulin. PMID:17256056

  7. Test Rig for Evaluating Active Turbine Blade Tip Clearance Control Concepts

    NASA Technical Reports Server (NTRS)

    Lattime, Scott B.; Steinetz, Bruce M.; Robbie, Malcolm G.; Erker, Arthur H.

    2004-01-01

    The objectives of the research presented in this viewgraph presentation are to 1) Design a mechanical ACC system for HPT tip seal clearance management; 2) Design a test rig to evaluate ACC system concepts. We have focused our efforts on designing mechanical ACC systems that articulate the seal shroud via mechanical linkages connected to actuators that reside outside the extreme environment of the HPT. We opted for this style of design due to a lack of high temperature/low profile actuators that are presently available. We have also selected multiple hydraulic actuators for this first generation ACC system. Fuel-draulic actuators are already a well established technology.

  8. Chaos vibration of pinion and rack steering trapezoidal mechanism containing two clearances

    NASA Astrophysics Data System (ADS)

    Wei, Daogao; Wang, Yu; Jiang, Tong; Zheng, Sifa; Zhao, Wenjing; Pan, Zhijie

    2017-08-01

    The multi-clearances of breaking type steering trapezoidal mechanism joints influences vehicle steering stability. Hence, to ascertain the influence of clearance value on steering stability, this paper takes the steering mechanism of a certain vehicle type as a prototype that can be simplified into a planar six-bar linkage, then establishes the system dynamic differential equations after considering the two clearances of tie rods and the steering knuckle arms. The influence of the clearance parameters on the movement stability of the steering mechanism is studied using a numerical computation method. Results show that when the two clearances are equal, the planar movement of the tie rods changes from period-doubling to chaos as the clearances increase. When the two clearances are 0.25 mm and 1.5 mm respectively, the planar movements of the two side tie rods come into chaos, causing the steering stability to deteriorate. Moreover, with the increase of clearances, turning moment fluctuates more intensively and the peak value increases.

  9. 78 FR 5859 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-28

    ... Personnel Management online USAJOBS system and the FAA's Automated Vacancy Information Access Tool for... (202) 395-6974, or mailed to the Office of Information and Regulatory Affairs, Office of Management and... Information Collection Clearance Officer, IT Enterprises Business Services Division, AES-200. [FR Doc. 2013...

  10. 77 FR 40403 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-09

    ... Information Collection Clearance Officer, IT Enterprises Business Services Division, AES-200. [FR Doc. 2012... Management System (FAAAMS) AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice and request for... about our intention to request the Office of Management and Budget (OMB) approval to renew an...

  11. 75 FR 66422 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-28

    ... Enterprises Business Services Division, AES-200, 800 Independence Ave., SW., Washington, DC 20591. Public... Information Collection Clearance Officer, IT Enterprises Business Services Division, AES-200. [FR Doc. 2010... about our intention to request the Office of Management and Budget (OMB) approval to renew an...

  12. 76 FR 13267 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-10

    ..., IT Enterprises Business Services Division, AES-200, 800 Independence Ave., SW., Washington, DC 20591... Information Collection Clearance Officer, IT Enterprises Business Services Division, AES-200. [FR Doc. 2011... about our intention to request the Office of Management and Budget (OMB) approval to renew an...

  13. 76 FR 13266 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-10

    ..., IT Enterprises Business Services Division, AES-200, 800 Independence Ave., SW., Washington, DC 20591... Information Collection Clearance Officer, IT Enterprises Business Services Division, AES-200. [FR Doc. 2011... about our intention to request the Office of Management and Budget (OMB) approval to renew an...

  14. Calculation of tip clearance effects in a transonic compressor rotor

    NASA Technical Reports Server (NTRS)

    Chima, R. V.

    1996-01-01

    The flow through the tip clearance region of a transonic compressor rotor (NASA rotor 37) was computed and compared to aerodynamic probe and laser anemometer data. Tip clearance effects were modeled both by gridding the clearance gap and by using a simple periodicity model across the ungridded gap. The simple model was run with both the full gap height, and with half the gap height to simulate a vena-contracta effect. Comparisons between computed and measured performance maps and downstream profiles were used to validate the models and to assess the effects of gap height on the simple clearance model. Recommendations were made concerning the use of the simple clearance model. Detailed comparisons were made between the gridded clearance gap solution and the laser anemometer data near the tip at two operating points. The computer results agreed fairly well with the data but overpredicted the extent of the casing separation and underpredicted the wake decay rate. The computations were then used to describe the interaction of the tip vortex, the passage shock, and the casing boundary layer.

  15. A Matter of Millimeters: Defining the Processes for Critical Clearances on Curiosity

    NASA Technical Reports Server (NTRS)

    Florow, Brandon

    2013-01-01

    The Mars Science Laboratory (MSL) mission presents an immense packaging problem in that it takes a rover the size of a car with a sky crane landing system and packs it tightly into a spacecraft. This creates many areas of close and critical clearances. Critical Clearances are defined as hardware-to-hardware or hardware-to-envelope clearances which fall below a pre-established location dependent threshold and pose a risk of hardware to hardware contact during events such as launch, entry, landing, and operations. Close Clearances, on the other hand, are defined as any clearance value that is chosen to be tracked but is larger than the critical clearance threshold for its region. Close clearances may be tracked for various reasons including uncertainty in design, large expected dynamic motion, etc.

  16. 76 FR 29804 - Submission for OMB Emergency Review: Request for Information for Multi-State Plans

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-23

    ... OFFICE OF PERSONNEL MANAGEMENT Submission for OMB Emergency Review: Request for Information for Multi-State Plans AGENCY: Office of Personnel Management. ACTION: Emergency Clearance Notice and request for comments. SUMMARY: Office of Personnel Management (OPM) submitted a request to the Office of...

  17. 75 FR 27561 - Agency Recordkeeping/Reporting Requirements Under Emergency Review by the Office of Management...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-17

    ... authorize emergency processing of its information collection clearance of the LIHEAP Program Integrity... approval for this information collection under procedures for emergency processing by May 30, 2010. A copy... has determined that additional information from each administering agency is necessary to assess...

  18. Alcohol consumption decreases lactate clearance in acutely injured patients☆

    PubMed Central

    Dezman, Zachary D.W.; Comer, Angela C.; Narayan, Mayur; Scalea, Thomas M.; Hirshon, Jon Mark; Smith, Gordon S.

    2017-01-01

    Introduction Alcohol, a common risk factor for injury, has direct toxic effects on the liver. The use of lactate clearance has been well described as an indicator of the adequacy of resuscitation in injured patients. We investigated whether acutely injured patients with positive blood alcohol content (+BAC) had less lactate clearance than sober patients. Methods We conducted a retrospective cohort study of acutely injured patients treated at an urban Level 1 trauma centre between January 2010 and December 2012. Blood alcohol and venous lactate levels were measured on all patients at the time of arrival. Study subjects were patients transported directly from the scene of injury, who had an elevated lactate concentration on arrival (≥3.0 mmol/L) and at least one subsequent lactate measurement within 24 h after admission. Lactate clearance ([Lactate1 − Lactate2]/Lactate1) was calculated for all patients. Chi-squared tests were used to compare values from sober and intoxicated subjects. Lactate clearance was plotted against alcohol levels and stratified by age and Injury Severity Score (ISS). Results Serial lactate concentration measurements were obtained in 3910 patients; 1674 of them had +BAC. Patients with +BAC were younger (mean age: 36.6 [SD 14.7] vs 41.0 [SD 19.9] years [p = 0.0001]), were more often male (83.4% vs 75.9% [p = 0.0001]), had more minor injuries (ISS < 9) (33.8% vs 27.1% [p = 0.0001]), had a lower in-hospital mortality rate (1.4% vs 3.9% [p = 0.0001]), but also had lower average lactate clearance (37.8% vs 47.6% [p = 0.0001]). The lactate clearance of the sober patients (47.6 [SD 33.5]) was twice that of those with +BAC >400 (23.5 [SD 6.5]). Lactate clearance decreased with increasing BAC irrespective of age and ISS. Conclusions In a large group of acutely injured patients, a dose-dependent decrease in lactate clearance was seen in those with elevated BAC. This relationship will cause a falsely elevated lactate reading or prolong lactate

  19. Estradiol and weight are covariates of paracetamol clearance in young women.

    PubMed

    Beleyn, B; Vermeersch, S; Kulo, A; Smits, A; Verbesselt, R; de Hoon, J N; Van Calsteren, K; Allegaert, K

    2014-01-01

    Paracetamol clearance differs between pregnant and non-pregnant women and between women with or without specific oral contraceptives (OCs). However, an association between female sex hormones and paracetamol clearance has never been explored. In total, 49 women at delivery, 8 female control subjects without OC use, historical data of 14 women taking OCs, and 15 postpartum observations with and without OCs were pooled to explore covariates of paracetamol clearance. All received a single intravenous 2-gram paracetamol dose, and blood samples were collected up to 6 h after dosing. High-performance liquid chromatography was used to quantify paracetamol. The area under the curve to time infinity (AUC0-∞) was determined and clearance (l/h·m(2)) was calculated by dose/ AUC0-∞. In addition, estradiol and progesterone were quantified by ELISA with electro-chemiluminescence. Median paracetamol clearance at delivery was significantly higher when compared to postpartum or non-pregnant women (11.9 vs. 6.42 and 8.4 l/h·m(2), at least p < 0.05), while an association between paracetamol clearance and estradiol was observed (R = 0.494, p < 0.0001). In non-pregnant subjects, there was no impact of OC exposure on paracetamol clearance. Multiple regression revealed a linear association (Radj = 0.41, p < 0.001) between paracetamol clearance and weight (p = 0.0462) and estradiol (p < 0.0001). Estradiol and weight in part explain the variation in paracetamol clearance in young women. © 2014 S. Karger AG, Basel.

  20. 32 CFR 644.521 - Limitations on clearance cost.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Limitations on clearance cost. 644.521 Section 644.521 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) REAL PROPERTY REAL ESTATE HANDBOOK Disposal Clearance of Explosive Hazards and Other Contamination from Proposed...

  1. 32 CFR 644.522 - Clearance of military scrap.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Clearance of military scrap. 644.522 Section 644.522 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) REAL PROPERTY REAL ESTATE HANDBOOK Disposal Clearance of Explosive Hazards and Other Contamination from Proposed...

  2. 77 FR 73113 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-07

    .... Albert R. Spence, FAA Assistant Information Collection Clearance Officer, IT Enterprises Business... comments about our intention to request the Office of Management and Budget (OMB) approval to renew an... requires that training centers maintain records for a period of one year to show trainee qualifications for...

  3. Time-Driven Activity-Based Costing in Emergency Medicine.

    PubMed

    Yun, Brian J; Prabhakar, Anand M; Warsh, Jonathan; Kaplan, Robert; Brennan, John; Dempsey, Kyle E; Raja, Ali S

    2016-06-01

    Value in emergency medicine is determined by both patient-important outcomes and the costs associated with achieving them. However, measuring true costs is challenging. Without an understanding of costs, emergency department (ED) leaders will be unable to determine which interventions might improve value for their patients. Although ongoing research may determine which outcomes are meaningful, an accurate costing system is also needed. This article reviews current costing mechanisms in the ED and their pitfalls. It then describes how time-driven activity-based costing may be superior to these current costing systems. Time-driven activity-based costing, in addition to being a more accurate costing system, can be used for process improvements in the ED. Copyright © 2015 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  4. Depressed reticuloendothelial clearance of platelets in rats after trauma.

    PubMed

    Kaplan, J E; Moon, D G; Minnear, F L; Saba, T M

    1984-02-01

    Platelet microembolization may contribute to microcirculatory and organ damage following trauma and shock. It is hypothesized that posttraumatic reticuloendothelial depression predisposes to such microembolization by failure to clear altered platelets from the circulation. The present study evaluated the short-term (1 h) clearance and organ localization of radiolabeled homologous damaged platelets in normal rats and in rats following sublethal Noble-Collip drum trauma. Platelets were collected in citrated platelet-rich plasma from normal rats and labeled with 51Cr in citrated saline. Platelets were altered by repeated centrifugation in protein-free medium. These platelets differed functionally and morphologically from normal platelets. Disappearance of iv injected damaged platelets conformed to a two-compartment exponential clearance. Velocity of clearance in the rapid compartment correlated with hepatic platelet localization, whereas velocity of clearance in the second compartment correlated with splenic platelet localization. Clearance rate of the rapid compartment was depressed at 1 h after trauma and elevated at 24 h. These changes were associated with a decrease in hepatic platelet localization at 1 h and an increase above normal at 24 h. Splenic platelet localization was decreased by 3 h following trauma. Pulmonary platelet localization was increased at all times following trauma. It is concluded that the posttrauma state is associated with a defect in the reticuloendothelial system clearance of altered platelets, which may augment embolization of platelets in the lung.

  5. Numerical investigation of tip clearance effects on the performance of ducted propeller

    NASA Astrophysics Data System (ADS)

    Ding, Yongle; Song, Baowei; Wang, Peng

    2015-09-01

    Tip clearance loss is a limitation of the improvement of turbomachine performance. Previous studies show the Tip clearance loss is generated by the leakage flow through the tip clearance, and is roughly linearly proportional to the gap size. This study investigates the tip clearance effects on the performance of ducted propeller. The investigation was carried out by solving the Navier-Stokes equations with the commercial Computational Fluid Dynamic (CFD) code CFX14.5. These simulations were carried out to determine the underlying mechanisms of the tip clearance effects. The calculations were performed at three different chosen advance ratios. Simulation results showed that the tip loss slope was not linearly at high advance due to the reversed pressure at the leading edge. Three type of vortical structures were observed in the tip clearance at different clearance size.

  6. 32 CFR 644.517 - Clearance of Army lands.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Clearance of Army lands. 644.517 Section 644.517 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) REAL PROPERTY REAL ESTATE HANDBOOK Disposal Clearance of Explosive Hazards and Other Contamination from Proposed Excess Land...

  7. Population Pharmacokinetics of Rifapentine and Desacetyl Rifapentine in Healthy Volunteers: Nonlinearities in Clearance and Bioavailability

    PubMed Central

    Lu, Yanhui; Bliven-Sizemore, Erin; Weiner, Marc; Nuermberger, Eric; Burman, William; Dorman, Susan E.; Dooley, Kelly E.

    2014-01-01

    Rifapentine is under active investigation as a potent drug that may help shorten the tuberculosis (TB) treatment duration. A previous rifapentine dose escalation study with daily dosing indicated a possible decrease in bioavailability as the dose increased and an increase in clearance over time for rifapentine and its active metabolite, desacetyl rifapentine. This study aimed to assess the effects of increasing doses on rifapentine absorption and bioavailability and to evaluate the clearance changes over 14 days. A population analysis was performed with nonlinear mixed-effects modeling. Absorption, time-varying clearance, bioavailability, and empirical and semimechanistic autoinduction models were investigated. A one-compartment model linked to a transit compartment absorption model best described the data. The bioavailability of rifapentine decreased linearly by 2.5% for each 100-mg increase in dose. The autoinduction model suggested a dose-independent linear increase in clearance of the parent drug and metabolite over time from 1.2 and 3.1 liters · h−1, respectively, after a single dose to 2.2 and 5.0 liters · h−1, respectively, after 14 once-daily doses, with no plateau being reached by day 14. In clinical trial simulations using the final model, rifapentine demonstrated less-than-dose-proportional pharmacokinetics, but there was no plateau in exposures over the dose range tested (450 to 1,800 mg), and divided dosing increased exposures significantly. Thus, the proposed compartmental model incorporating daily dosing of rifapentine over a wide range of doses and time-related changes in bioavailability and clearance provides a useful tool for estimation of drug exposure that can be used to optimize rifapentine dosing for TB treatment. (This study has been registered at ClinicalTrials.gov under registration no. NCT01162486.) PMID:24614383

  8. Noncontact Capacitive Clearance Control System For Laser Cutting Machines

    NASA Astrophysics Data System (ADS)

    Topkaya, Ahmet; Schmall, Karl-Heinz; Majoli, Ralf

    1989-03-01

    For a continuous high quality laser cut, it is necessary among other things to position the focal point of the laser beam correctly. This means that a constant clearance between the cutting head and the workpiece with a tolerance of +/- 0.Imm must he ensured. When cutting corrugated automobile bodysheet for example, a good quality cut can only be achieved with automatic clearance control. In the following, a method of automatic clearance control is described using the assistance of a noncontact capacitive sensor system. The copper nozzle of the laser cutting head acts as the electrode of the clearance sensor. The nozzle electrode and the workpiece build a small variable capacitance depending on the clearance. A change of clearance also changes the capacitance, which in turn influences a high frequency oscillator circuit. This shift in frequency is then converted into an analogue DC signal, which can be used to operate a servo motor control for the positioning of the laser cutting head in a closed loop servo system. Laser cutting heads with clearance sensor nozzles of different shapes, suited fur most applications in the industry, with focal lengths from 2.5" to 5" have been developed. They are capable to cut metal sheet from 0.2 to 12 mm of thickness, using CO2-lasers with output power up to 2.5 kW. For special applications involving difficult workpiece topographies in automobile production applications special "trunk" nozzles have been developed. For 5-axis cutting machines and robots, new laser cutting heads with integrated nozzle sensors in combination with a high dynamic Z-axis motor drive are in a stage of development.

  9. Omega-3 polyunsaturated fatty acids promote amyloid-β clearance from the brain through mediating the function of the glymphatic system.

    PubMed

    Ren, Huixia; Luo, Chuanming; Feng, Yanqing; Yao, Xiaoli; Shi, Zhe; Liang, Fengyin; Kang, Jing X; Wan, Jian-Bo; Pei, Zhong; Su, Huanxing

    2017-01-01

    Impairment of amyloid-β (Aβ) clearance leads to Aβ accumulation in the brain during the development of Alzheimer's disease (AD). Strategies that can restore or improve the clearance function hold great promise in delaying or preventing the onset of AD. Here, we show that n-3 polyunsaturated fatty acids (PUFAs), by use of fat-1 transgenic mice and oral administration of fish oil, significantly promote interstitial Aβ clearance from the brain and resist Aβ injury. Such beneficial effects were abolished in Aqp4-knockout mice, suggesting that the AQP4-dependent glymphatic system is actively involved in the promoting the effects of n-3 PUFAs on the clearance of extracellular Aβ. Imaging on clarified brain tissues clearly displayed that n-3 PUFAs markedly inhibit the activation of astrocytes and protect the AQP4 polarization in the affected brain region after Aβ injection. The results of the present study prove a novel mechanism by which n-3 PUFAs exert protective roles in reducing Aβ accumulation via mediating the glymphatic system function.-Ren, H., Luo, C., Feng, Y., Yao, X., Shi, Z., Liang, F., Kang, J. X., Wan, J.-B., Pei, Z., Su, H. Omega-3 polyunsaturated fatty acids promote amyloid-β clearance from the brain through mediating the function of the glymphatic system. © FASEB.

  10. The Microstructure of Active and Quiet Sleep as Cortical Delta Activity Emerges in Infant Rats

    PubMed Central

    Seelke, Adele M. H.; Blumberg, Mark S.

    2008-01-01

    Study objectives: Previous investigators have suggested that quiet sleep (QS) in rats develops rapidly upon the emergence of cortical delta activity around postnatal day (P)11 and that the presence of “half-activated” active sleep (AS) suggests that infant sleep is initially disorganized. To address these issues, we examined the temporal organization of sleep states during the second postnatal week in rats as delta activity emerges. Design: Subjects were P9, P11, and P13 Sprague-Dawley rats. Electroencephalogram and nuchal electromyogram electrodes were implanted, and data were recorded at thermoneutrality for 2 hours. Results: At all ages, using electromyogram and behavioral criteria, QS (defined as nuchal atonia and behavioral quiescence) dominated the first third of each sleep period, whereas AS (defined as nuchal atonia accompanied by myoclonic twitching) dominated the last third. When delta activity, which was first detected at P11, could be added to the definition of QS, gross assessments of sleep-state organization were not altered, although it was now possible to identify brief periods of QS interposed between periods of AS. No evidence of “half-activated” AS was found. Finally, “slow activity transients” were detected and were primarily associated with QS; their rate of occurrence declined as delta activity emerged. Conclusions: When delta activity emerges at P11, it integrates smoothly with periods of QS, as defined using electromyogram and behavioral criteria alone. Delta activity helps to refine estimates of QS duration but does not reflect a significant alteration of sleep-state organization. Rather, this organization is expressed much earlier in ontogeny as fluctuations in muscle tone and associated phasic motor activity. Citation: Seelke AMH; Blumberg MS. The microstructure of active and quiet sleep as cortical delta activity emerges in infant rats. SLEEP 2008;31(5):691–699. PMID:18517038

  11. Latency reversal and viral clearance to cure HIV-1

    PubMed Central

    Margolis, David M.; Garcia, J. Victor; Hazuda, Daria J.; Haynes, Barton F.

    2016-01-01

    Research toward a cure for human immunodeficiency virus type 1 (HIV-1) infection has joined prevention and treatment efforts in the global public health agenda. A major approach to HIV eradication envisions antiretroviral suppression, paired with targeted therapies to enforce the expression of viral antigen from quiescent HIV-1 genomes, and immunotherapies to clear latent infection. These strategies are targeted to lead to viral eradication—a cure for AIDS. Paired testing of latency reversal and clearance strategies has begun, but additional obstacles to HIV eradication may emerge. Nevertheless, there is reason for optimism that advances in long-acting antiretroviral therapy and HIV prevention strategies will contribute to efforts in HIV cure research and that the implementation of these efforts will synergize to markedly blunt the effect of the HIV pandemic on society. PMID:27463679

  12. 76 FR 13263 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-10

    ... Enterprises Business Services Division, AES-200, 800 Independence Ave., SW., Washington, DC 20591. Public... Clearance Officer, IT Enterprises Business Services Division, AES-200. [FR Doc. 2011-5466 Filed 3-9-11; 8:45... public comments about our intention to request the Office of Management and Budget (OMB) approval to...

  13. Delayed clearance of triglyceride‐rich lipoproteins in young, healthy obese subjects†

    PubMed Central

    Goll, R.; Lekahl, S.; Moen, O. S.; Florholmen, J.

    2015-01-01

    Summary Obesity is associated with the metabolic syndrome. The aims were, first, to study the postprandial triglyceride clearance in young, healthy obese subjects and, second, to investigate if fasting triglycerides can predict delayed postprandial triglyceride clearance. Eighteen apparently healthy, obese subjects with no clinical signs of metabolic disturbances participated. Controls were age‐ and sex‐matched, healthy, normal weight subjects. Subclinical markers of metabolic disturbances were assessed by measuring postprandial triglycerides in serum and in chylomicrons by oral fat tolerance test. Postprandial triglyceride clearance for 8 h was assessed indirectly as removal of the lipid from serum during the oral fat tolerance test. Insulin resistance was measured by the homeostasis model assessment of insulin resistance (HOMA‐IR). Twelve (66%) of the apparently healthy obese individuals had insulin resistance measured by HOMA‐IR. There was a delayed clearance of serum triglycerides and chylomicron triglycerides at 6 h when compared with the control group, while, at 8 h, the differences were only detected for the chylomicron triglyceride clearance. Triglyceride response was significantly greater in the obese subjects. Fasting triglycerides in upper normal level predicted a delayed postprandial triglyceride clearance and insulin resistance. In young, apparently healthy obese subjects early metabolic disturbances including insulin resistance and delayed postprandial triglyceride clearance can be detected. Fasting serum triglyceride in upper normal level predicted delayed postprandial triglyceride clearance and insulin resistance. PMID:26469529

  14. Cleaning up the mess: cell corpse clearance in Caenorhabditis elegans.

    PubMed

    Pinto, Sérgio Morgado; Hengartner, Michael Otmar

    2012-12-01

    Genetic and cell biology studies have led to the identification in Caenorhabditis elegans of a set of evolutionary conserved cellular mechanisms responsible for the clearance of apoptotic cells. Based on the phenotype of cell corpse clearance mutants, corpse clearance can be divided into three distinct, but linked steps: corpse recognition, corpse internalization, and corpse degradation. Work in recent years has led to a better understanding of the molecular pathways that mediate each of these steps. Here, we review recent developments in our understanding of in vivo cell corpse clearance in this simple but most elegant model organism. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Apoptotic Cell Clearance in Development.

    PubMed

    Shklover, Jeny; Levy-Adam, Flonia; Kurant, Estee

    2015-01-01

    Programmed cell death and its specific form apoptosis play an important role during development of multicellular organisms. They are crucial for morphogenesis and organ sculpting as well as for adjusting cell number in different systems. Removal of apoptotic cells is the last critical step of apoptosis. Apoptotic cells are properly and efficiently recognized and eliminated through phagocytosis, which is performed by professional and nonprofessional phagocytes. Phagocytosis of apoptotic cells or apoptotic cell clearance is a dynamic multistep process, involving interactions between phagocytic receptors and ligands on apoptotic cells, which are highly conserved in evolution. However, this process is extremely redundant in mammals, containing multiple factors playing similar roles in the process. Using model organisms such as Caenorhabditis elegans, Drosophila melanogaster, zebrafish, and mouse permits addressing fundamental questions in developmental cell clearance by a comprehensive approach including powerful genetics and cell biological tools enriched by live imaging. Recent studies in model organisms have enhanced significantly our understanding of the molecular and cellular basis of apoptotic cell clearance during development. Here, we review the current knowledge and illuminate the great potential of the research performed in genetic models, which opens new directions in developmental biology. © 2015 Elsevier Inc. All rights reserved.

  16. N-linked glycan truncation causes enhanced clearance of plasma-derived von Willebrand factor.

    PubMed

    O'Sullivan, J M; Aguila, S; McRae, E; Ward, S E; Rawley, O; Fallon, P G; Brophy, T M; Preston, R J S; Brady, L; Sheils, O; Chion, A; O'Donnell, J S

    2016-12-01

    Essentials von Willebrands factor (VWF) glycosylation plays a key role in modulating in vivo clearance. VWF glycoforms were used to examine the role of specific glycan moieties in regulating clearance. Reduction in sialylation resulted in enhanced VWF clearance through asialoglycoprotein receptor. Progressive VWF N-linked glycan trimming resulted in increased macrophage-mediated clearance. Click to hear Dr Denis discuss clearance of von Willebrand factor in a free presentation from the ISTH Academy SUMMARY: Background Enhanced von Willebrand factor (VWF) clearance is important in the etiology of both type 1 and type 2 von Willebrand disease (VWD). In addition, previous studies have demonstrated that VWF glycans play a key role in regulating in vivo clearance. However, the molecular mechanisms underlying VWF clearance remain poorly understood. Objective To define the molecular mechanisms through which VWF N-linked glycan structures influence in vivo clearance. Methods By use of a series of exoglycosidases, different plasma-derived VWF (pd-VWF) glycoforms were generated. In vivo clearance of these glycoforms was then assessed in VWF -/- mice in the presence or absence of inhibitors of asialoglycoprotein receptor (ASGPR), or following clodronate-induced macrophage depletion. Results Reduced amounts of N-linked and O-linked sialylation resulted in enhanced pd-VWF clearance modulated via ASGPR. In addition to this role of terminal sialylation, we further observed that progressive N-linked glycan trimming also resulted in markedly enhanced VWF clearance. Furthermore, these additional N-linked glycan effects on clearance were ASGPR-independent, and instead involved enhanced macrophage clearance that was mediated, at least in part, through LDL receptor-related protein 1. Conclusion The carbohydrate determinants expressed on VWF regulate susceptibility to proteolysis by ADAMTS-13. In addition, our findings now further demonstrate that non-sialic acid carbohydrate

  17. 76 FR 13265 - Agency Information Collection Activities: Requests for Comments; Clearance of Renewed Approval of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-10

    ... Enterprises Business Services Division, AES-200, 800 Independence Ave., SW., Washington, DC 20591. Public... Clearance Officer, IT Enterprises Business Services Division, AES-200. [FR Doc. 2011-5470 Filed 3-9-11; 8:45... comments about our intention to request the Office of Management and Budget (OMB) approval to renew an...

  18. Magnetic helicity in emerging solar active regions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Y.; Hoeksema, J. T.; Bobra, M.

    Using vector magnetic field data from the Helioseismic and Magnetic Imager instrument aboard the Solar Dynamics Observatory, we study magnetic helicity injection into the corona in emerging active regions (ARs) and examine the hemispheric helicity rule. In every region studied, photospheric shearing motion contributes most of the helicity accumulated in the corona. In a sample of 28 emerging ARs, 17 follow the hemisphere rule (61% ± 18% at a 95% confidence interval). Magnetic helicity and twist in 25 ARs (89% ± 11%) have the same sign. The maximum magnetic twist, which depends on the size of an AR, is inferredmore » in a sample of 23 emerging ARs with a bipolar magnetic field configuration.« less

  19. Effects of airborne pollutants on mucociliary clearance.

    PubMed

    Wolff, R K

    1986-04-01

    The mucociliary clearance system is a first line of defense against inhaled agents, and so its compromise can adversely affect health. The purpose of this paper is to provide a review of data on the effect of in vivo air pollutant exposures on the clearance of test particles from airways. Data from both animals and humans are compared whenever possible, so that estimates of human health effects may be made. Mechanisms of action are also discussed, presenting the view that for low level exposures, changes in secretions are probably responsible for most observed changes in clearance. The pollutants pertinent to this review are those that are common in the environment and most likely to have impacts on large numbers of people: sulfur oxides, sulfuric acid mist, O3, NO2, particulates, diesel exhaust, and cigarette smoke.

  20. Experimental models for studying mucociliary clearance.

    PubMed

    King, M

    1998-01-01

    Respiratory tract mucus is a viscoelastic gel, the rheological properties of which are determined mainly by its content of mucous glycoproteins and water. The rheology and quantity of mucus, in concert with ciliary factors, are the major determinants of mucociliary clearance. A wide range of animal models for studying the secretion and clearance of mucus are available. Ex vivo models, such as the frog palate or excised bovine trachea, provide direct, meaningful data regarding the clearability of mucus. Rodent models of chronic bronchitis, based on irritant gas or cigarette smoke exposure, show important features of the human condition in a relatively short time. The rheological characterization of mucus is made difficult by the small quantities obtainable, particularly from normal animals. Large animal models, such as the dog or sheep, although more expensive, offer many advantages, such as the ability to carry out long-term serial measurements, and to make integrated measurements of the clearance of mucus, ciliary function, epithelial ion transport, and the rheology of mucus in the same preparation.

  1. Acupuncture promotes mTOR-independent autophagic clearance of aggregation-prone proteins in mouse brain.

    PubMed

    Tian, Tian; Sun, Yanhong; Wu, Huangan; Pei, Jian; Zhang, Jing; Zhang, Yi; Wang, Lu; Li, Bin; Wang, Lihua; Shi, Jiye; Hu, Jun; Fan, Chunhai

    2016-01-21

    Acupuncture has historically been practiced to treat medical disorders by mechanically stimulating specific acupoints with fine needles. Despite its well-documented efficacy, its biological basis remains largely elusive. In this study, we found that mechanical stimulation at the acupoint of Yanglingquan (GB34) promoted the autophagic clearance of α-synuclein (α-syn), a well known aggregation-prone protein closely related to Parkinson's disease (PD), in the substantia nigra par compacta (SNpc) of the brain in a PD mouse model. We found the protein clearance arose from the activation of the autophagy-lysosome pathway (ALP) in a mammalian target of rapamycin (mTOR)-independent approach. Further, we observed the recovery in the activity of dopaminergic neurons in SNpc, and improvement in the motor function at the behavior level of PD mice. Whereas acupuncture and rapamycin, a chemical mTOR inhibitor, show comparable α-syn clearance and therapeutic effects in the PD mouse model, the latter adopts a distinctly different, mTOR-dependent, autophagy induction process. Due to this fundamental difference, acupuncture may circumvent adverse effects of the rapamycin treatment. The newly discovered connection between acupuncture and autophagy not only provides a new route to understanding the molecular mechanism of acupuncture but also sheds new light on cost-effective and safe therapy of neurodegenerative diseases.

  2. 76 FR 76737 - Emergency Clearance: Public Information Collection Requirements Submitted to the Office of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-08

    ... information collection burden. We are, however, requesting an emergency review of the information collection... for emergency review. We are requesting an emergency review to ensure compliance with section 1862(a... Information Collection: Medicare Fee-for-Service Prepayment Medical Review; Use: The information required...

  3. Measurement of Rotating Blade Tip Clearance with Fibre-Optic Probe

    NASA Astrophysics Data System (ADS)

    Cao, S. Z.; Duan, F. J.; Zhang, Y. G.

    2006-10-01

    This paper described a tip clearance measuring system with fibre-optic probe. The system is based on a novel tip clearance sensor of optical fibre-bundle mounted on the casing, rotating speed synchronization sensor mounted on the rotating shaft, the tip clearance preamplification processing circuit followed by high speed data-acquisition unit. A novel tip clearance sensor of trifurcated optical fibre bundle was proposed and demonstrated. It is independent of material of measured surface but capacitive probe demands target conductive. Measurements can be taken under severe conditions such as ionization. Sensor circuitry and data acquisition circuit were successfully designed. With the help of Rotation synchronized sensor, all the blades can be detected in real-time. Because of fibre-optic sensor, the measuring system has commendably frequency response, which can work well in high rotating speed from 0-15000rpm.The measurement range of tip clearance is 0-3mm with 25um precision.

  4. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  5. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  6. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  7. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  8. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  9. 75 FR 7648 - Agency Information Collection Activities: Emergency Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-22

    ..., recipients, and representative payees: Braille and Microsoft Word files (on data compact discs). Current...) Braille, or (5) Microsoft Word. This call did not require OMB clearance. However, there may be respondents...

  10. Parabolic quantitative structure-activity relationships and photodynamic therapy: application of a three-compartment model with clearance to the in vivo quantitative structure-activity relationships of a congeneric series of pyropheophorbide derivatives used as photosensitizers for photodynamic therapy.

    PubMed

    Potter, W R; Henderson, B W; Bellnier, D A; Pandey, R K; Vaughan, L A; Weishaupt, K R; Dougherty, T J

    1999-11-01

    An open three-compartment pharmacokinetic model was applied to the in vivo quantitative structure-activity relationship (QSAR) data of a homologous series of pyropheophorbide photosensitizers for photodynamic therapy (PDT). The physical model was a lipid compartment sandwiched between two identical aqueous compartments. The first compartment was assumed to clear irreversibly at a rate K0. The measured octanol-water partition coefficients, P(i) (where i is the number of carbons in the alkyl chain) and the clearance rate K0 determined the clearance kinetics of the drugs. Solving the coupled differential equations of the three-compartment model produced clearance kinetics for each of the sensitizers in each of the compartments. The third compartment was found to contain the target of PDT. This series of compounds is quite lipophilic. Therefore these drugs are found mainly in the second compartment. The drug level in the third compartment represents a small fraction of the tissue level and is thus not accessible to direct measurement by extraction. The second compartment of the model accurately predicted the clearance from the serum of mice of the hexyl ether of pyropheophorbide a, one member of this series of compounds. The diffusion and clearance rate constants were those found by fitting the pharmacokinetics of the third compartment to the QSAR data. This result validated the magnitude and mechanistic significance of the rate constants used to model the QSAR data. The PDT response to dose theory was applied to the kinetic behavior of the target compartment drug concentration. This produced a pharmacokinetic-based function connecting PDT response to dose as a function of time postinjection. This mechanistic dose-response function was fitted to published, single time point QSAR data for the pheophorbides. As a result, the PDT target threshold dose together with the predicted QSAR as a function of time postinjection was found.

  11. Estimation of end point foot clearance points from inertial sensor data.

    PubMed

    Santhiranayagam, Braveena K; Lai, Daniel T H; Begg, Rezaul K; Palaniswami, Marimuthu

    2011-01-01

    Foot clearance parameters provide useful insight into tripping risks during walking. This paper proposes a technique for the estimate of key foot clearance parameters using inertial sensor (accelerometers and gyroscopes) data. Fifteen features were extracted from raw inertial sensor measurements, and a regression model was used to estimate two key foot clearance parameters: First maximum vertical clearance (m x 1) after toe-off and the Minimum Toe Clearance (MTC) of the swing foot. Comparisons are made against measurements obtained using an optoelectronic motion capture system (Optotrak), at 4 different walking speeds. General Regression Neural Networks (GRNN) were used to estimate the desired parameters from the sensor features. Eight subjects foot clearance data were examined and a Leave-one-subject-out (LOSO) method was used to select the best model. The best average Root Mean Square Errors (RMSE) across all subjects obtained using all sensor features at the maximum speed for m x 1 was 5.32 mm and for MTC was 4.04 mm. Further application of a hill-climbing feature selection technique resulted in 0.54-21.93% improvement in RMSE and required fewer input features. The results demonstrated that using raw inertial sensor data with regression models and feature selection could accurately estimate key foot clearance parameters.

  12. High-Speed, capacitance-based tip clearance sensing

    NASA Astrophysics Data System (ADS)

    Haase, W. C.; Haase, Z. S.

    This paper discusses recent advances in tip clearance measurement systems for turbine engines using capacitive probes. Real time measurements of individual blade pulses are generated using wideband signal processing providing 3 dB bandwidths of typically 5 MHz. Subsequent mixed-signal processing circuitry provide real-time measurements of maximum, minimum, and average clearance with latencies of one blade-to-blade time interval. Both guarded and unguarded probe configurations are possible with the system. Calibration techniques provide high accuracy measurements.

  13. 77 FR 9235 - Agency Information Collection Activities; Proposed Collection; Comment Request; Emergency...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-16

    ... 188,900 hours at a cost of $8.7 million. The average burden for emergency planning activities is 21... Activities; Proposed Collection; Comment Request; Emergency Planning and Release Notification Requirements Under Emergency Planning and Community Right-To-Know Act Sections 302, 303, and 304; EPA ICR No. 1395.08...

  14. Health Departments’ Engagement in Emergency Preparedness Activities: The Influence of Health Informatics Capacity

    PubMed Central

    Shah, Gulzar H.; Newell, Bobbie; Whitworth, Ruth E.

    2016-01-01

    Background: Local health departments (LHDs) operate in a complex and dynamic public health landscape, with changing demands on their emergency response capacities. Informatics capacities might play an instrumental role in aiding LHDs emergency preparedness. This study aimed to explore the extent to which LHDs’ informatics capacities are associated with their activity level in emergency preparedness and to identify which health informatics capacities are associated with improved emergency preparedness. Methods: We used the 2013 National Profile of LHDs study to perform Poisson regression of emergency preparedness activities. Results: Only 38.3% of LHDs participated in full-scale exercises or drills for an emergency in the 12 months period prior to the survey, but a much larger proportion provided emergency preparedness training to staff (84.3%), and/or participated in tabletop exercises (76.4%). Our multivariable analysis showed that after adjusting for several resource-related LHD characteristics, LHDs with more of the 6 information systems still tend to have slightly more preparedness activities. In addition, having a designated emergency preparedness coordinator, and having one or more emergency preparedness staff were among the most significant factors associated with LHDs performing more emergency preparedness activities. Conclusion: LHDs might want to utilize better health information systems and information technology tools to improve their activity level in emergency preparedness, through improved information dissemination, and evidence collection. PMID:27694648

  15. The emergence of spontaneous activity in neuronal cultures

    NASA Astrophysics Data System (ADS)

    Orlandi, J. G.; Alvarez-Lacalle, E.; Teller, S.; Soriano, J.; Casademunt, J.

    2013-01-01

    In vitro neuronal networks of dissociated hippocampal or cortical tissues are one of the most attractive model systems for the physics and neuroscience communities. Cultured neurons grow and mature, develop axons and dendrites, and quickly connect to their neighbors to establish a spontaneously active network within a week. The resulting neuronal network is characterized by a combination of excitatory and inhibitory neurons coupled through synaptic connections that interact in a highly nonlinear manner. The nonlinear behavior emerges from the dynamics of both the neurons' spiking activity and synaptic transmission, together with biological noise. These ingredients give rise to a rich repertoire of phenomena that are still poorly understood, including the emergence and maintenance of periodic spontaneous activity, avalanches, propagation of fronts and synchronization. In this work we present an overview on the rich activity of cultured neuronal networks, and detail the minimal theoretical considerations needed to describe experimental observations.

  16. Testing of a Microwave Blade Tip Clearance Sensor at the NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Woike, Mark R.; Roeder, James W.; Hughes, Christopher E.; Bencic, Timothy J.

    2009-01-01

    The development of new active tip clearance control and structural health monitoring schemes in turbine engines and other types of rotating machinery requires sensors that are highly accurate and can operate in a high-temperature environment. The use of a microwave sensor to acquire blade tip clearance and tip timing measurements is being explored at the NASA Glenn Research Center. The microwave blade tip clearance sensor works on principles that are very similar to a short-range radar system. The sensor sends a continuous microwave signal towards a target and measures the reflected signal. The phase difference of the reflected signal is directly proportional to the distance between the sensor and the target being measured. This type of sensor is beneficial in that it has the ability to operate at extremely high temperatures and is unaffected by contaminants that may be present in turbine engines. The use of microwave sensors for this application is a new concept. Techniques on calibrating the sensors along with installation effects are not well quantified as they are for other sensor technologies. Developing calibration techniques and evaluating installation effects are essential in using these sensors to make tip clearance and tip timing measurements. As a means of better understanding these issues, the microwave sensors were used on a benchtop calibration rig, a large axial vane fan, and a turbofan. Background on the microwave tip clearance sensor, an overview of their calibration, and the results from their use on the axial vane fan and the turbofan will be presented in this paper.

  17. Testing of a Microwave Blade Tip Clearance Sensor at the NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Woike, Mark R.; Roeder, James W.; Hughes, Christopher E.; Bencic, Timothy J.

    2009-01-01

    The development of new active tip clearance control and structural health monitoring schemes in turbine engines and other types of rotating machinery requires sensors that are highly accurate and can operate in a high temperature environment. The use of a microwave sensor to acquire blade tip clearance and tip timing measurements is being explored at the NASA Glenn Research Center. The microwave blade tip clearance sensor works on principles that are very similar to a short range radar system. The sensor sends a continuous microwave signal towards a target and measures the reflected signal. The phase difference of the reflected signal is directly proportional to the distance between the sensor and the target being measured. This type of sensor is beneficial in that it has the ability to operate at extremely high temperatures and is unaffected by contaminants that may be present in turbine engines. The use of microwave sensors for this application is a new concept. Techniques on calibrating the sensors along with installation effects are not well quantified as they are for other sensor technologies. Developing calibration techniques and evaluating installation effects are essential in using these sensors to make tip clearance and tip timing measurements. As a means of better understanding these issues, the microwave sensors were used on a bench top calibration rig, a large axial vane fan, and a turbofan. Background on the microwave tip clearance sensor, an overview of their calibration, and the results from their use on the axial vane fan and the turbofan will be presented in this paper.

  18. Select critically ill patients at risk of augmented renal clearance: experience in a Malaysian intensive care unit.

    PubMed

    Adnan, S; Ratnam, S; Kumar, S; Paterson, D; Lipman, J; Roberts, J; Udy, A A

    2014-11-01

    Augmented renal clearance (ARC) refers to increased solute elimination by the kidneys. ARC has considerable implications for altered drug concentrations. The aims of this study were to describe the prevalence of ARC in a select cohort of patients admitted to a Malaysian intensive care unit (ICU) and to compare measured and calculated creatinine clearances in this group. Patients with an expected ICU stay of <24 hours plus an admission serum creatinine concentration <120 µmol/l, were enrolled from May to July 2013. Twenty-four hour urinary collections and serum creatinine concentrations were used to measure creatinine clearance. A total of 49 patients were included, with a median age of 34 years. Most study participants were male and admitted after trauma. Thirty-nine percent were found to have ARC. These patients were more commonly admitted in emergency (P=0.03), although no other covariants were identified as predicting ARC, likely due to the inclusion criteria and the study being under-powered. Significant imprecision was demonstrated when comparing calculated Cockcroft-Gault creatinine clearance (Crcl) and measured Crcl. Bias was larger in ARC patients, with Cockcroft-Gault Crcl being significantly lower than measured Crcl (P <0.01) and demonstrating poor correlation (rs=-0.04). In conclusion, critically ill patients with 'normal' serum creatinine concentrations have varied Crcl. Many are at risk of ARC, which may necessitate individualised drug dosing. Furthermore, significant bias and imprecision between calculated and measured Crcl exists, suggesting clinicians should carefully consider which method they employ in assessing renal function.

  19. The Role of Radial Clearance on the Performance of Foil Air Bearings

    NASA Technical Reports Server (NTRS)

    Radil, Kevin; Howard, Samuel; Dykas, Brian

    2002-01-01

    Load capacity tests were conducted to determine how radial clearance variations affect the load capacity coefficient of foil air bearings. Two Generation III foil air bearings with the same design but possessing different initial radial clearances were tested at room temperature against an as-ground PS304 coated journal operating at 30,000 rpm. Increases in radial clearance were accomplished by reducing the journal's outside diameter via an in-place grinding system. From each load capacity test the bearing load capacity coefficient was calculated from the rule-of-thumb (ROT) model developed for foil air bearings. The test results indicate that, in terms of the load capacity coefficient, radial clearance has a direct impact on the performance of the foil air bearing. Each test bearing exhibited an optimum radial clearance that resulted in a maximum load capacity coefficient. Relative to this optimum value are two separate operating regimes that are governed by different modes of failure. Bearings operating with radial clearances less than the optimum exhibit load capacity coefficients that are a strong function of radial clearance and are prone to a thermal runaway failure mechanism and bearing seizure. Conversely, a bearing operating with a radial clearance twice the optimum suffered only a 20 percent decline in its maximum load capacity coefficient and did not experience any thermal management problems. However, it is unknown to what degree these changes in radial clearance had on other performance parameters, such as the stiffness and damping properties of the bearings.

  20. Discrete-Layer Piezoelectric Plate and Shell Models for Active Tip-Clearance Control

    NASA Technical Reports Server (NTRS)

    Heyliger, P. R.; Ramirez, G.; Pei, K. C.

    1994-01-01

    The objectives of this work were to develop computational tools for the analysis of active-sensory composite structures with added or embedded piezoelectric layers. The targeted application for this class of smart composite laminates and the analytical development is the accomplishment of active tip-clearance control in turbomachinery components. Two distinct theories and analytical models were developed and explored under this contract: (1) a discrete-layer plate theory and corresponding computational models, and (2) a three dimensional general discrete-layer element generated in curvilinear coordinates for modeling laminated composite piezoelectric shells. Both models were developed from the complete electromechanical constitutive relations of piezoelectric materials, and incorporate both displacements and potentials as state variables. This report describes the development and results of these models. The discrete-layer theories imply that the displacement field and electrostatic potential through-the-thickness of the laminate are described over an individual layer rather than as a smeared function over the thickness of the entire plate or shell thickness. This is especially crucial for composites with embedded piezoelectric layers, as the actuating and sensing elements within these layers are poorly represented by effective or smeared properties. Linear Lagrange interpolation polynomials were used to describe the through-thickness laminate behavior. Both analytic and finite element approximations were used in the plane or surface of the structure. In this context, theoretical developments are presented for the discrete-layer plate theory, the discrete-layer shell theory, and the formulation of an exact solution for simply-supported piezoelectric plates. Finally, evaluations and results from a number of separate examples are presented for the static and dynamic analysis of the plate geometry. Comparisons between the different approaches are provided when

  1. Latency reversal and viral clearance to cure HIV-1.

    PubMed

    Margolis, David M; Garcia, J Victor; Hazuda, Daria J; Haynes, Barton F

    2016-07-22

    Research toward a cure for human immunodeficiency virus type 1 (HIV-1) infection has joined prevention and treatment efforts in the global public health agenda. A major approach to HIV eradication envisions antiretroviral suppression, paired with targeted therapies to enforce the expression of viral antigen from quiescent HIV-1 genomes, and immunotherapies to clear latent infection. These strategies are targeted to lead to viral eradication--a cure for AIDS. Paired testing of latency reversal and clearance strategies has begun, but additional obstacles to HIV eradication may emerge. Nevertheless, there is reason for optimism that advances in long-acting antiretroviral therapy and HIV prevention strategies will contribute to efforts in HIV cure research and that the implementation of these efforts will synergize to markedly blunt the effect of the HIV pandemic on society. Copyright © 2016, American Association for the Advancement of Science.

  2. Mechanisms of astrocytic K(+) clearance and swelling under high extracellular K(+) concentrations.

    PubMed

    Murakami, Shingo; Kurachi, Yoshihisa

    2016-03-01

    In response to the elevation of extracellular K(+) concentration ([K(+)]out), astrocytes clear excessive K(+) to maintain conditions necessary for neural activity. K(+) clearance in astrocytes occurs via two processes: K(+) uptake and K(+) spatial buffering. High [K(+)]out also induces swelling in astrocytes, leading to edema and cell death in the brain. Despite the importance of astrocytic K(+) clearance and swelling, the underlying mechanisms remain unclear. Here, we report results from a simulation analysis of astrocytic K(+) clearance and swelling. Astrocyte models were constructed by incorporating various mechanisms such as intra/extracellular ion concentrations of Na(+), K(+), and Cl(-), cell volume, and models of Na,K-ATPase, Na-K-Cl cotransporter (NKCC), K-Cl cotransporter, inwardly-rectifying K(+) (KIR) channel, passive Cl(-) current, and aquaporin channel. The simulated response of astrocyte models under the uniform distribution of high [K(+)]out revealed significant contributions of NKCC and Na,K-ATPase to increases of intracellular K(+) and Cl(-) concentrations, and swelling. Moreover, we found that, under the non-uniform distribution of high [K(+)]out, KIR channels localized at synaptic clefts absorbed excess K(+) by depolarizing the equivalent potential of K(+) (E K) above membrane potential, while K(+) released through perivascular KIR channels was enhanced by hyperpolarizing E K and depolarizing membrane potential. Further analysis of simulated drug effects revealed that astrocyte swelling was modulated by blocking each of the ion channels and transporters. Our simulation analysis revealed controversial mechanisms of astrocytic K(+) clearance and swelling resulting from complex interactions among ion channels and transporters.

  3. 48 CFR 832.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 5 2012-10-01 2012-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS... finance office clearance. Contracting officers must obtain approval from the DSPE before taking the...

  4. 48 CFR 32.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... finance office clearance. The contracting officer shall obtain the approval of the contract finance office...

  5. 48 CFR 32.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... finance office clearance. The contracting officer shall obtain the approval of the contract finance office...

  6. 48 CFR 832.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 5 2013-10-01 2013-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS... finance office clearance. Contracting officers must obtain approval from the DSPE before taking the...

  7. 48 CFR 32.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... finance office clearance. The contracting officer shall obtain the approval of the contract finance office...

  8. 48 CFR 832.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS... finance office clearance. Contracting officers must obtain approval from the DSPE before taking the...

  9. 48 CFR 832.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS... finance office clearance. Contracting officers must obtain approval from the DSPE before taking the...

  10. 48 CFR 32.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... finance office clearance. The contracting officer shall obtain the approval of the contract finance office...

  11. Secretion clearance strategies in Australian and New Zealand Intensive Care Units.

    PubMed

    Ntoumenopoulos, George; Hammond, Naomi; Watts, Nicola R; Thompson, Kelly; Hanlon, Gabrielle; Paratz, Jennifer D; Thomas, Peter

    2017-06-26

    To describe the processes of care for secretion clearance in adult, intubated and mechanically ventilated patients in Australian and New Zealand Intensive Care Units (ICUs). A prospective, cross-sectional study was conducted through the Australian and New Zealand Intensive Care Society Clinical Trials Group (ANZICS CTG) Point Prevalence Program. Forty-seven ICUs collected data from 230 patients intubated and ventilated on the study day. Secretion clearance techniques beyond standard suctioning were used in 84/230 (37%) of patients during the study period. Chest wall vibration 34/84 (40%), manual lung hyperinflation 24/84 (29%), chest wall percussion 20/84 (24%), postural drainage/patient positioning 17/84 (20%) and other techniques including mobilisation 15/84 (18%), were the most common secretion clearance techniques employed. On average (SD), patients received airway suctioning 8.8 (5.0) times during the 24-h study period. Mucus plugging events were infrequent (2.7%). The additional secretion clearance techniques were provided by physiotherapy staff in 24/47 (51%) ICUs and by both nursing and physiotherapy staff in the remaining 23/47 (49%) ICUs. One-third of intubated and ventilated patients received additional secretion clearance techniques. Mucus plugging events were infrequent with these additional secretion clearance approaches. Prospective studies must examine additional secretion clearance practices, prevalence of mucus plugging episodes and impact on patient outcomes. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  12. Factors effective on peritoneal phosphorus transport and clearance in peritoneal dialysis patients
.

    PubMed

    Cebeci, Egemen; Gursu, Meltem; Uzun, Sami; Karadag, Serhat; Kazancioglu, Rumeyza; Ozturk, Savas

    2017-02-01

    Transport characteristics of phosphorus are different from other small solutes that are evaluated in routine peritoneal equilibration test (PET) in peritoneal dialysis (PD) patients. We aimed to evaluate peritoneal phosphorus clearance and permeability, and their relationship with peritoneal membrane transport type and creatinine clearance as well as factors affecting peritoneal phosphorus clearance. 70 adult patients on a PD program were included in our study. Phosphorus transport status was classified according to dialysate/plasma (D/P) phosphorus at the 4th hour of PET as slow transporter (< 0.47), slow-average transporter (0.47 - 0.56), fast-average transporter (0.57 - 0.67), and fast transporter (> 0.67). We evaluated the relationship of peritoneal phosphorus clearance and transport type with PD regime, phosphorus level, and presence of residual renal function in addition to investigating factors that are effective on peritoneal phosphorus clearance. D/P phosphorus and peritoneal phosphorus clearance were positively correlated with D/P creatinine and peritoneal creatinine clearance, respectively. Automated PD and continuous ambulatory PD patients were similar regarding phosphorus and creatinine clearances and transport status based on D/P phosphorus. The major determinant of peritoneal phosphorus clearance was anuria status. Anuric patients had higher dialysate volume (11.6 ± 3.0 L vs. 8.4 ± 2.1 L, p < 0.001) and therefore higher peritoneal phosphorus clearance (61.7 ± 15.1 L/week/1.73 m2 vs. 48.4 ± 14.0 L/week/1.73 m2, p = 0.001). Hyperphosphatemia was present in 40% and 11% of anuric patients and those with residual renal function, respectively (p = 0.005). Peritoneal phosphorus transport characteristics are similar to that of creatinine. Although increased dialysis dose may increase peritoneal phosphorus clearance, it may be insufficient to prevent hyperphosphatemia in anuric patients.
.

  13. Total plasma clearance versus urinary plasma clearance of (51)Cr-EDTA in patients with cirrhosis with and without fluid retention.

    PubMed

    Henriksen, Ulrik L; Hansen, Hanne B; Ring-Larsen, Helmer; Bendtsen, Flemming; Henriksen, Jens H

    2015-01-01

    In patients with fluid retention, the total plasma clearance of (51)Cr-EDTA (ClP) may overestimate the glomerular filtration rate (GFR). The present study was therefore undertaken in order to compare ClP with the urinary plasma clearance of (51)Cr-EDTA (ClU) in patients with cirrhosis with and without fluid retention. A total of 136 patients with cirrhosis (24 without fluid retention, 112 with ascites) received a quantitative intravenous injection of (51)Cr-EDTA followed by plasma and quantitative urinary samples for 5 hours. ClP was determined from the injected dose relative to the plasma concentration-time area, extrapolated to infinity. ClU was determined as urinary excretion relative to the plasma concentration-time area up to voiding. In patients without fluid retention, the difference between ClP and ClU (ClP - ClU = ClΔ) was mean 4.5 mL/min/1.73 m(2). In patients with ascites, ClΔ was significantly higher (17.6 mL/min/1.73 m(2), p < 0.0001). ClΔ increased with lower values of GFR (r = - 0.458, p < 0.001). Repeated measurements of ClU in a subgroup of patients with fluid retention (n = 25) gave almost identical values. Different types of corrections of one-pool clearance were almost identical with ClP, except for higher clearance values, which were somewhat underestimated by the former. In patients with fluid retention and ascites ClP and corrected one-pool clearance overestimates GFR substantially. Although ClU may underestimate GFR slightly, patients with ascites should collect urine quantitatively in order to obtain a reliable measurement of GFR.

  14. Underkeel Clearance Study.

    DTIC Science & Technology

    1981-09-01

    EnterewJ N00014-80-C-0395 CONTENTS Page EXECUTIVE SUMMARY 1.0 INTRODUCTION 1.1 The Underlying Problem ................. 1-1 1.2 The Current Study...3-4 3.2.4 CVN Berthinq Facilities .................... 3-4 ii! JI N00014-80-C-0395 CONTENTS (continued) 3.3 Hydrologic Conditions...Drafts ...................... 3-10 3.8.3 Underkeel Clearance ........ .............. 3-10 4.0 THE ANALYSIS 4.1 The Physical Model

  15. 48 CFR 1432.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 5 2013-10-01 2013-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR... finance office clearance. The CO shall obtain approval of the bureau finance office prior to taking...

  16. 48 CFR 1432.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR... finance office clearance. The CO shall obtain approval of the bureau finance office prior to taking...

  17. 48 CFR 1432.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR... finance office clearance. The CO shall obtain approval of the bureau finance office prior to taking...

  18. 48 CFR 1432.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 5 2012-10-01 2012-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR... finance office clearance. The CO shall obtain approval of the bureau finance office prior to taking...

  19. Single-sample 99mTc-diethylenetriamine penta-acetate plasma clearance in advanced renal failure by the mean sojourn time approach.

    PubMed

    Gref, Margareta C; Karp, Kjell H

    2009-03-01

    The single-sample Tc-diethylenetriamine penta-acetate (DTPA) clearance method by Christensen and Groth is recommended by the Radionuclides in Nephrourology Committee on Renal Clearance for use in adults with an estimated glomerular filtration rate (GFR) > or = 30 ml/min. The purpose of this study was to test a new Tc-DTPA single-sample low clearance formula for GFR lesser than 30 ml/min. Twenty-one adult patients (29 investigations) were included. Reference clearance was calculated with both Cr-EDTA and Tc-DTPA according to Brøchner-Mortensen with samples drawn between 3 and 24 h. Single-sample clearance was calculated from a 24 h sample using the low clearance formula(Equation is included in full-text article.) C(t) is the activity of the tracer in the plasma sample t minutes after the injection and Q0 is the injected amount. ECV is the extracellular volume in ml defined as the distribution volume of the tracer. ECV is estimated from the body surface area as ECV=8116.6xbody surface area-28.2. The mean difference between reference and Tc-DTPA single-sample clearance was -0.5 ml/min (SD 1.0 ml/min) for Tc-DTPA and -0.8 ml/min (SD 1.2 ml/min) for Cr-EDTA as reference clearance. In adult patients it is possible, even with GFR lesser than 30 ml/min, to get an accurate determination of Tc-DTPA plasma clearance from a single sample using the mean sojourn time approach. The blood sample should be obtained about 24 h after injection of the GFR tracer.

  20. Tear clearance implications for ocular surface health.

    PubMed

    de Paiva, Cintia Sade; Pflugfelder, Stephen C

    2004-03-01

    Tear clearance/turnover provides a global assessment of the function of the lacrimal functional unit and of tear exchange on the ocular surface. It is an indirect measure of dry eye induced inflammation on the ocular surface. It shows better correlation with the severity of ocular irritation symptoms and corneal epithelial disease in dry eye than the Schirmer 1 test. Delayed tear clearance may prove to be the best measure for identifying patients with tear film disorders who may respond to anti-inflammatory therapy.

  1. Fiber-optic laser Doppler turbine tip clearance probe

    NASA Astrophysics Data System (ADS)

    Büttner, Lars; Pfister, Thorsten; Czarske, Jürgen

    2006-05-01

    A laser Doppler based method for in situ single blade tip clearance measurements of turbomachines with high precision is presented for what we believe is the first time. The sensor is based on two superposed fanlike interference fringe systems generated by two laser wavelengths from a fiber-coupled, passive, and therefore compact measurement head employing diffractive optics. Tip clearance measurements at a transonic centrifugal compressor performed during operation at 50,000 rpm (833 Hz, 586 m/s tip speed) are reported. At these speeds the measured uncertainty of the tip position was less than 20 μm, a factor of 2 more accurate than that of capacitive probes. The sensor offers great potential for in situ and online high-precision tip clearance measurements of metallic and nonmetallic turbine blades.

  2. Fiber-optic laser Doppler turbine tip clearance probe.

    PubMed

    Büttner, Lars; Pfister, Thorsten; Czarske, Jürgen

    2006-05-01

    A laser Doppler based method for in situ single blade tip clearance measurements of turbomachines with high precision is presented for what we believe is the first time. The sensor is based on two superposed fanlike interference fringe systems generated by two laser wavelengths from a fiber-coupled, passive, and therefore compact measurement head employing diffractive optics. Tip clearance measurements at a transonic centrifugal compressor performed during operation at 50,000 rpm (833 Hz, 586 m/s tip speed) are reported. At these speeds the measured uncertainty of the tip position was less than 20 microm, a factor of 2 more accurate than that of capacitive probes. The sensor offers great potential for in situ and online high-precision tip clearance measurements of metallic and nonmetallic turbine blades.

  3. CF6 Jet Engine Diagnostics Program: High pressure compressor clearance investigation

    NASA Technical Reports Server (NTRS)

    Radomski, M. A.

    1982-01-01

    The effects of high pressure compressor clearance changes on engine performance were experimentally determined on a CF6 core engine. The results indicate that a one percent reduction in normalized average clearance, expressed as a fraction of airfoil length, improves compressor efficiency by one percent. Compressor clearances are reduced by the application of rotor bore cooling, insulation of the stator casing, and use of a low coefficient of expansion material in the aft stages. This improvement amounts to a reduction of normalized average clearance of 0.78 percent, relative to CF6-60 compressor, which is equivalent to an improvement in compressor efficiency of 0.78 percent.

  4. Effect of isolated hepatic ischemia on organic anion clearance and oxidative metabolism.

    PubMed

    Minard, G; Bynoe, R; Wood, G C; Fabian, T C; Croce, M; Kudsk, K A

    1992-04-01

    Hepatic failure is frequently seen following severe hemorrhagic shock, sepsis, and trauma. Clearance of various drugs has been used to evaluate hepatocellular dysfunction, including indocyanine green (ICG), an organic anionic dye that is transported similarly to bilirubin, and antipyrine (AP), a marker of oxidative phosphorylation. Previous investigators have noted a decrease in ICG excretion following systemic hemorrhage. The effect of isolated hepatic ischemia on the clearances of ICG and AP was studied in 16 pigs after 90 minutes of vascular occlusion to the liver. Antipyrine clearance decreased almost 50% from baseline values at 24 and 72 hours after the ischemia procedure, indicating a significant depression in the cytochrome P-450 system. On the other hand, ICG clearance did not change significantly. In conclusion, ICG clearance is not depressed after isolated hepatic ischemia in pigs. Changes in organic anion clearance after systemic hemorrhage may be because of release of toxic products from ischemic peripheral tissue.

  5. 49 CFR 392.12 - Highway-rail crossings; safe clearance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 5 2013-10-01 2013-10-01 false Highway-rail crossings; safe clearance. 392.12... DRIVING OF COMMERCIAL MOTOR VEHICLES Driving of Commercial Motor Vehicles § 392.12 Highway-rail crossings; safe clearance. No driver of a commercial motor vehicle shall drive onto a highway-rail grade crossing...

  6. 49 CFR 392.12 - Highway-rail crossings; safe clearance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 5 2014-10-01 2014-10-01 false Highway-rail crossings; safe clearance. 392.12... DRIVING OF COMMERCIAL MOTOR VEHICLES Driving of Commercial Motor Vehicles § 392.12 Highway-rail crossings; safe clearance. No driver of a commercial motor vehicle shall drive onto a highway-rail grade crossing...

  7. 76 FR 17615 - Highway-Rail Grade Crossing; Safe Clearance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-30

    ...-2006-25660] RIN 2137-AE69 & 2126-AB04 Highway-Rail Grade Crossing; Safe Clearance AGENCY: Pipeline and... PHMSA and FMCSA extend the comment period for the Highway-Rail Grade Crossing; Safe Clearance Notice of... Alliance (CVSA) requested that PHMSA and FMCSA extend the comment period for the Highway-Rail Grade...

  8. 48 CFR 832.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Progress Payments Based on Costs 832.502-2 Contract finance office clearance. Contracting...

  9. 48 CFR 32.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Progress Payments Based on Costs 32.502-2 Contract finance office clearance. The contracting...

  10. 14 CFR 29.411 - Ground clearance: tail rotor guard.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Ground clearance: tail rotor guard. 29.411 Section 29.411 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... System Loads § 29.411 Ground clearance: tail rotor guard. (a) It must be impossible for the tail rotor to...

  11. 14 CFR 27.411 - Ground clearance: tail rotor guard.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Ground clearance: tail rotor guard. 27.411 Section 27.411 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... System Loads § 27.411 Ground clearance: tail rotor guard. (a) It must be impossible for the tail rotor to...

  12. 14 CFR 27.411 - Ground clearance: tail rotor guard.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Ground clearance: tail rotor guard. 27.411 Section 27.411 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... System Loads § 27.411 Ground clearance: tail rotor guard. (a) It must be impossible for the tail rotor to...

  13. 14 CFR 29.411 - Ground clearance: tail rotor guard.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Ground clearance: tail rotor guard. 29.411 Section 29.411 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... System Loads § 29.411 Ground clearance: tail rotor guard. (a) It must be impossible for the tail rotor to...

  14. Hemodialysis clearance of glyphosate following a life-threatening ingestion of glyphosate-surfactant herbicide.

    PubMed

    Garlich, F M; Goldman, M; Pepe, J; Nelson, L S; Allan, M J; Goldstein, D A; Goldfarb, D S; Hoffman, R S

    2014-01-01

    Ingestion of glyphosate-surfactant herbicides (GlySH) can result in acute kidney injury, electrolyte abnormalities, acidosis, cardiovascular collapse, and death. In severe toxicity, the use of hemodialysis is reported, but largely unsupported by kinetic analysis. We report the dialysis clearance of glyphosate following a suicidal ingestion of a glyphosate-containing herbicide. A 62-year-old man was brought to the emergency department (ED) 8.5 h after drinking a bottle of commercial herbicide containing a 41% solution of glyphosate isopropylamine, in polyoxyethyleneamine (POEA) surfactant and water. He was bradycardic and obtunded with respiratory depression necessitating intubation and mechanical ventilation. Initial laboratory results were significant for the following: pH, 7.11; PCO2, 64 mmHg; PO2, 48 mmHg; potassium, 7.8 mEq/L; Cr 3.3, mg/dL; bicarbonate, 22 mEq/L; anion gap, 18 mEq/L; and lactate, 7.5 mmol/L. Acidosis and hyperkalemia persisted despite ventilation and fluid resuscitation. The patient underwent hemodialysis 16 h post ingestion, after which he demonstrated resolution of acidosis and hyperkalemia, and improvement in clinical status. Serum glyphosate concentrations were drawn prior to, during, and after hemodialysis. The extraction ratio and hemodialysis clearance were calculated to be 91.8% and 97.5 mL/min, respectively. We demonstrate the successful clearance of glyphosate using hemodialysis, with corresponding clinical improvement in a patient with several poor prognostic factors (advanced age, large volume ingested, and impaired consciousness). The effects of hemodialysis on the surfactant compound are unknown. Hemodialysis can be considered when severe acidosis and acute kidney injury complicate ingestion of glyphosate-containing products.

  15. Deriving an explicit hepatic clearance equation accounting for plasma protein binding and hepatocellular uptake.

    PubMed

    Yoon, Miyoung; Clewell, Harvey J; Andersen, Melvin E

    2013-02-01

    High throughput in vitro biochemical and cell-based assays have the promise to provide more mechanism-based assessments of the adverse effects of large numbers of chemicals. One of the most challenging hurdles for interpreting in vitro toxicity findings is the need for reverse dosimetry tools that estimate the exposures that will give concentrations in vivo similar to the active concentrations in vitro. Recent experience using IVIVE approaches to estimate in vivo pharmacokinetics (Wetmore et al., 2012) identified the need to develop a hepatic clearance equation that explicitly accounted for a broader set of protein binding and membrane transport processes and did not depend on a well-mixed description of the liver compartment. Here we derive an explicit steady-state hepatic clearance equation that includes these factors. In addition to the derivation, we provide simple computer code to calculate steady-state extraction for any combination of blood flow, membrane transport processes and plasma protein-chemical binding rates. This expanded equation provides a tool to estimate hepatic clearance for a more diverse array of compounds. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. 32 CFR 644.516 - Clearance of Air Force lands.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Clearance of Air Force lands. 644.516 Section 644... Excess Land and Improvements § 644.516 Clearance of Air Force lands. The Chief of Engineers has no responsibility for inspecting or clearing excess Air Force land of explosives or chemical/biological contaminants...

  17. 48 CFR 1432.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING Progress Payments Based on Costs 1432.502-2 Contract finance office clearance. The CO shall...

  18. 31 CFR 205.20 - What is a clearance pattern?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., unless additional data is required to accurately represent the flow of Federal funds. (e) If a State uses... FEDERAL-STATE FUNDS TRANSFERS Rules Applicable to Federal Assistance Programs Included in a Treasury-State Agreement § 205.20 What is a clearance pattern? States use clearance patterns to project when funds are paid...

  19. Domiciliary humidification improves lung mucociliary clearance in patients with bronchiectasis.

    PubMed

    Hasani, A; Chapman, T H; McCool, D; Smith, R E; Dilworth, J P; Agnew, J E

    2008-01-01

    Inspired air humidification has been reported to show some benefit in bronchiectatic patients. We have investigated the possibility that one effect might be to enhance mucociliary clearance. Such enhancement might, if it occurs, help to lessen the risks of recurrent infective episodes. Using a radioaerosol technique, we measured lung mucociliary clearance before and after 7 days of domiciliary humidification. Patients inhaled high flow saturated air at 37 degrees C via a patient-operated humidification nasal inhalation system for 3 h per day. We assessed tracheobronchial mucociliary clearance from the retention of (99m)Tc-labelled polystyrene tracer particles monitored for 6 h, with a follow-up 24-h reading. Ten out of 14 initially recruited patients (age 37-75 years; seven females) completed the study (two withdrew after their initial screening and two prior to the initial clearance test). Seven patients studied were non-smokers; three were ex-smokers (1-9 pack-years). Initial tracer radioaerosol distribution was closely similar between pre- and post-treatment. Following humidification, lung mucociliary clearance significantly improved, the area under the tracheobronchial retention curve decreased from 319 +/- 50 to 271 +/- 46%h (p < 0.07). Warm air humidification treatment improved lung mucociliary clearance in our bronchiectatic patients. Given this finding plus increasing laboratory and clinical interest in humidification mechanisms and effects, we believe further clinical trials of humidification therapy are desirable, coupled with analysis of humidification effects on mucus properties and transport.

  20. 48 CFR 245.7101-4 - DD Form 1640, Request for Plant Clearance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false DD Form 1640, Request for Plant Clearance. 245.7101-4 Section 245.7101-4 Federal Acquisition Regulations System DEFENSE... Forms 245.7101-4 DD Form 1640, Request for Plant Clearance. Use to request plant clearance assistance or...

  1. Sport and active recreation injuries in Australia: evidence from emergency department presentations.

    PubMed

    Finch, C; Valuri, G; Ozanne-Smith, J

    1998-09-01

    Despite the rise in specialist clinical services for the management of sports and active recreation injury, many patients attend hospital emergency departments for treatment. The purpose of this study was to describe sports injury cases presented to selected hospital emergency departments around Australia for the period 1989-1993. Routinely collected emergency department injury presentation data from the Australian National Injury Surveillance Unit were examined. Data on 98,040 sports and active recreation emergency department presentations were analysed. Sports and active recreation activities were ranked according to frequency of presentation. Relative proportions of injury type and body region injured were determined. Data are presented separately for children (<15 years of age) and adults (>15 years of age). Among the 10 activities that most commonly led to a sports or active recreation injury presentation for all ages were cycling, Australian football, basketball, soccer, cricket, netball, and rugby. For children, injuries were also commonly associated with roller skating/blading, skateboarding, and trampolining. Hockey, martial arts, and dancing injuries were frequent in adults. Most sporting injuries occurred during organised competition or practice whereas the active recreation injuries occurred in a variety of settings. Fractures, strains, and sprains, particularly to the lower and upper extremities, were common types of injury. The rich, but nevertheless limited, information available about sports and active recreation injuries from data collected in emergency departments indicates that these activities are a common context for injury at the community level in Australia.

  2. HPT Clearance Control: Intelligent Engine Systems-Phase 1

    NASA Technical Reports Server (NTRS)

    2005-01-01

    The following work has been completed to satisfy the Phase I Deliverables for the "HPT Clearance Control" project under NASA GRC's "Intelligent Engine Systems" program: (1) Need for the development of an advanced HPT ACC system has been very clearly laid out, (2) Several existing and potential clearance control systems have been reviewed, (3) A scorecard has been developed to document the system, performance (fuel burn, range, payload, etc.), thermal, and mechanical characteristics of the existing clearance control systems, (4) Engine size and flight cycle selection for the advanced HPT ACC system has been reviewed with "large engine"/"long range mission" combination showing the most benefit, (5) A scoring criteria has been developed to tie together performance parameters for an objective, data driven comparison of competing systems, and (6) The existing HPT ACC systems have been scored based on this scoring system.

  3. Genome-wide study of methotrexate clearance replicates SLCO1B1

    PubMed Central

    Ramsey, Laura B.; Panetta, John C.; Smith, Colton; Yang, Wenjian; Fan, Yiping; Winick, Naomi J.; Martin, Paul L.; Cheng, Cheng; Devidas, Meenakshi; Pui, Ching-Hon; Evans, William E.; Hunger, Stephen P.; Loh, Mignon

    2013-01-01

    Methotrexate clearance can influence the cure of and toxicity in children with acute lymphoblastic leukemia (ALL). We estimated methotrexate plasma clearance for 1279 patients with ALL treated with methotrexate (24-hour infusion of a 1 g/m2 dose or 4-hour infusion of a 2 g/m2 dose) on the Children's Oncology Group P9904 and P9905 protocols. Methotrexate clearance was lower in older children (P = 7 × 10−7), girls (P = 2.7 × 10−4), and those who received a delayed-intensification phase (P = .0022). A genome-wide analysis showed that methotrexate clearance was associated with polymorphisms in the organic anion transporter gene SLCO1B1 (P = 2.1 × 10−11). This replicates findings using different schedules of high-dose methotrexate in St Jude ALL treatment protocols; a combined meta-analysis yields a P value of 5.7 × 10−19 for the association of methotrexate clearance with SLCO1B1 SNP rs4149056. Validation of this variant with 5 different treatment regimens of methotrexate solidifies the robustness of this pharmacogenomic determinant of methotrexate clearance. This study is registered at http://www.clinicaltrials.gov as NCT00005585 and NCT00005596. PMID:23233662

  4. Cervical Spine Clearance in Pediatric Trauma Centers: The Need for Standardization and an Evidence-based Protocol.

    PubMed

    Pannu, Gurpal S; Shah, Mitesh P; Herman, Marty J

    Cervical spine clearance in the pediatric trauma patient represents a particularly challenging task. Unfortunately, standardized clearance protocols for pediatric cervical clearance are poorly reported in the literature and imaging recommendations demonstrate considerable variability. With the use of a web-based survey, this study aims to define the methods utilized by pediatric trauma centers throughout North America. Specific attention was given to the identification of personnel responsible for cervical spine care, diagnostic imaging modalities used, and the presence or absence of a written pediatric cervical spine clearance protocol. A 10-question electronic survey was given to members of the newly formed Pediatric Cervical Spine Study Group, all of whom are active POSNA members. The survey was submitted via the online service SurveyMonkey (https://www.surveymonkey.com/r/7NVVQZR). The survey assessed the respondent's institution demographics, such as trauma level and services primarily responsible for consultation and operative management of cervical spine injuries. In addition, respondents were asked to identify the protocols and primary imaging modality used for cervical spine clearance. Finally, respondents were asked if their institution had a documented cervical spine clearance protocol. Of the 25 separate institutions evaluated, 21 were designated as level 1 trauma centers. Considerable variation was reported with regards to the primary service responsible for cervical spine clearance. General Surgery/Trauma (44%) is most commonly the primary service, followed by a rotating schedule (33%), Neurosugery (11%), and Orthopaedic Surgery (8%). Spine consults tend to be seen most commonly by a rotating schedule of Orthopaedic Surgery and Neurosurgery. The majority of responding institutions utilize computed tomographic imaging (46%) as the primary imaging modality, whereas 42% of hospitals used x-ray primarily. The remaining institutions reported using a

  5. Circadian Clearance of a Fungal Pathogen from the Lung Is Not Based on Cell-intrinsic Macrophage Rhythms.

    PubMed

    Chen, Shan; Fuller, Kevin K; Dunlap, Jay C; Loros, Jennifer J

    2018-02-01

    Circadian rhythms govern immune cell function, giving rise to time-of-day variation in the recognition and clearance of bacterial or viral pathogens; to date, however, no such regulation of the host-fungal interaction has been described. In this report, we use murine models to explore circadian control of either fungal-macrophage interactions in vitro or pathogen clearance from the lung in vivo. First, we show that expression of the important fungal pattern recognition receptor Dectin-1 ( clec7a), from either bone marrow-derived or peritoneum-derived macrophages, is not under circadian regulation at either the level of transcript or cell surface protein expression. Consistent with this finding, the phagocytic activity of macrophages in culture against spores of the pathogen Aspergillus fumigatus also did not vary over time. To account for the multiple cell types and processes that may be coordinated in a circadian fashion in vivo, we examined the clearance of A. fumigatus from the lungs of immunocompetent mice. Interestingly, animals inoculated at night demonstrated a 2-fold enhancement in clearance compared with animals inoculated in the morning. Taken together, our data suggest that while molecular recognition of fungi by immune cells may not be circadian, other processes in vivo may still allow for time-of-day differences in fungal clearance from the lung.

  6. [Functional deterioration of basic daily living activities after an emergency service consultation].

    PubMed

    Gutiérrez Rodríguez, J; Varela Suárez, C; Alonso Alvarez, M; Solano Jaurrieta, J J

    2000-05-01

    To determine the incidence of functional decline of elderly patients discharged from an emergency department and to analized functional impairment as a risk of readmission. A prospective cohort aged 75 or older were followed up after discharge from an emergency department between 01-02-95 and 01-04-95. The study protocol included sociodemografics, clinicals, functionals and mentalsoutcomes. We studied the incidence of functional decline in basic activities of daily living, with Barthel Index, and association with the risk of readmission. The sample was composed by 125 elders (mean aged 81.9 +/- 4.6 years and 60.8% were women). The incidence of functional decline in basic activities of daily living at the visit to emergency department was 20.8% and one moth after discharge was 18.4%. Both activities with more functional impairment were bathing, dressing and movility activities. Functional decline was associated with the risk of readmission at emergency department (Odds Ratio = 4.1 [1.4-11.8]) 20% of patients who are discharged of emergency department present a new functional impairment in basics activities of daily living. Functional decline is associated with the risk of readmission one moth after discharged.

  7. Inert gas clearance from tissue by co-currently and counter-currently arranged microvessels

    PubMed Central

    Lu, Y.; Michel, C. C.

    2012-01-01

    To elucidate the clearance of dissolved inert gas from tissues, we have developed numerical models of gas transport in a cylindrical block of tissue supplied by one or two capillaries. With two capillaries, attention is given to the effects of co-current and counter-current flow on tissue gas clearance. Clearance by counter-current flow is compared with clearance by a single capillary or by two co-currently arranged capillaries. Effects of the blood velocity, solubility, and diffusivity of the gas in the tissue are investigated using parameters with physiological values. It is found that under the conditions investigated, almost identical clearances are achieved by a single capillary as by a co-current pair when the total flow per tissue volume in each unit is the same (i.e., flow velocity in the single capillary is twice that in each co-current vessel). For both co-current and counter-current arrangements, approximate linear relations exist between the tissue gas clearance rate and tissue blood perfusion rate. However, the counter-current arrangement of capillaries results in less-efficient clearance of the inert gas from tissues. Furthermore, this difference in efficiency increases at higher blood flow rates. At a given blood flow, the simple conduction-capacitance model, which has been used to estimate tissue blood perfusion rate from inert gas clearance, underestimates gas clearance rates predicted by the numerical models for single vessel or for two vessels with co-current flow. This difference is accounted for in discussion, which also considers the choice of parameters and possible effects of microvascular architecture on the interpretation of tissue inert gas clearance. PMID:22604885

  8. Effect of injection routes on the biodistribution, clearance, and tumor uptake of carbon dots.

    PubMed

    Huang, Xinglu; Zhang, Fan; Zhu, Lei; Choi, Ki Young; Guo, Ning; Guo, Jinxia; Tackett, Kenneth; Anilkumar, Parambath; Liu, Gang; Quan, Qimeng; Choi, Hak Soo; Niu, Gang; Sun, Ya-Ping; Lee, Seulki; Chen, Xiaoyuan

    2013-07-23

    The emergence of photoluminescent carbon-based nanomaterials has shown exciting potential in the development of benign nanoprobes. However, the in vivo kinetic behaviors of these particles that are necessary for clinical translation are poorly understood to date. In this study, fluorescent carbon dots (C-dots) were synthesized and the effect of three injection routes on their fate in vivo was explored by using both near-infrared fluorescence and positron emission tomography imaging techniques. We found that C-dots are efficiently and rapidly excreted from the body after all three injection routes. The clearance rate of C-dots is ranked as intravenous > intramuscular > subcutaneous. The particles had relatively low retention in the reticuloendothelial system and showed high tumor-to-background contrast. Furthermore, different injection routes also resulted in different blood clearance patterns and tumor uptakes of C-dots. These results satisfy the need for clinical translation and should promote efforts to further investigate the possibility of using carbon-based nanoprobes in a clinical setting. More broadly, we provide a testing blueprint for in vivo behavior of nanoplatforms under various injection routes, an important step forward toward safety and efficacy analysis of nanoparticles.

  9. 7 CFR 1927.53 - Costs of title clearance and closing of transactions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 12 2010-01-01 2010-01-01 false Costs of title clearance and closing of transactions... and Loan Closing § 1927.53 Costs of title clearance and closing of transactions. The borrower or the... payment of all costs of title clearance and closing of the transaction and will arrange for payment before...

  10. Selenoprotein Expression in Macrophages Is Critical for Optimal Clearance of Parasitic Helminth Nippostrongylus brasiliensis*

    PubMed Central

    Nelson, Shakira M.; Shay, Ashley E.; James, Jamaal L.; Carlson, Bradley A.; Urban, Joseph F.; Prabhu, K. Sandeep

    2016-01-01

    The plasticity of macrophages is evident in helminthic parasite infections, providing protection from inflammation. Previously we demonstrated that the micronutrient selenium induces a phenotypic switch in macrophage activation from a classically activated (pro-inflammatory; M1/CAM) toward an alternatively activated (anti-inflammatory; M2/AAM) phenotype, where cyclooxygenase (COX)-dependent cyclopentenone prostaglandin J2 (15d-PGJ2) plays a key role. Here, we hypothesize that dietary selenium modulates macrophage polarization toward an AAM phenotype to assist in the increasing clearance of adult Nippostrongylus brasiliensis, a gastrointestinal nematode parasite. Mice on a selenium-adequate (0.08 ppm) diet significantly augmented intestinal AAM presence while decreasing adult worms and fecal egg production when compared with infection of mice on selenium-deficient (<0.01 ppm) diet. Further increase in dietary selenium to supraphysiological levels (0.4 ppm) had very little or no impact on worm expulsion. Normal adult worm clearance and enhanced AAM marker expression were observed in the selenium-supplemented Trspfl/flCreWT mice that express selenoproteins driven by tRNASec (Trsp), whereas N. brasiliensis-infected Trspfl/flCreLysM selenium-supplemented mice showed a decreased clearance, with lowered intestinal expression of several AAM markers. Inhibition of the COX pathway with indomethacin resulted in delayed worm expulsion in selenium-adequate mice. This was rescued with 15d-PGJ2, which partially recapitulated the effect of selenium supplementation on fecal egg output in addition to increasing markers of AAMs in the small intestine. Antagonism of PPARγ blocked the effect of selenium. These results suggest that optimal expression of selenoproteins and selenium-dependent production of COX-derived endogenous prostanoids, such as Δ12-PGJ2 and 15d-PGJ2, may regulate AAM activation to enhance anti-helminthic parasite responses. PMID:26644468

  11. Clearance of HCV RNA following acute hepatitis A superinfection.

    PubMed

    Cacopardo, B; Nunnari, G; Nigro, L

    2009-05-01

    A transient reduction of hepatitis C virus replication during the course of acute hepatitis A virus infection has already been reported in the literature. The present study reports the case study of a subject with chronic hepatitis due to hepatitis C virus who went on to develop an acute hepatitis A. From the early onset of acute disease, hepatitis C virus ribonucleic acid became undetectable. Following recovery from acute hepatitis, alanine amino-transferase levels became persistently normal and liver biopsy revealed a reduction in the Knodell histological activity index score. Hepatitis C virus ribonucleic acid clearance was maintained up to 4 years after the onset of acute hepatitis A. During the course of the acute disease, a sharp increase in interferon gamma levels was detected in serum and in the supernatant of both unstimulated and phytoemagglutinin/lipopolysaccharide-stimulated peripheral blood mononuclear cells. Interferon gamma levels were still high 3 months later. We hypothesize that acute hepatitis A virus superinfection during the course of chronic hepatitis C may lead to hepatitis C virus ribonucleic acid clearance through an immunological mechanism related to interferon gamma production.

  12. Railway Tunnel Clearance Inspection Method Based on 3D Point Cloud from Mobile Laser Scanning

    PubMed Central

    Zhou, Yuhui; Wang, Shaohua; Mei, Xi; Yin, Wangling; Lin, Chunfeng; Mao, Qingzhou

    2017-01-01

    Railway tunnel clearance is directly related to the safe operation of trains and upgrading of freight capacity. As more and more railway are put into operation and the operation is continuously becoming faster, the railway tunnel clearance inspection should be more precise and efficient. In view of the problems existing in traditional tunnel clearance inspection methods, such as low density, slow speed and a lot of manual operations, this paper proposes a tunnel clearance inspection approach based on 3D point clouds obtained by a mobile laser scanning system (MLS). First, a dynamic coordinate system for railway tunnel clearance inspection has been proposed. A rail line extraction algorithm based on 3D linear fitting is implemented from the segmented point cloud to establish a dynamic clearance coordinate system. Second, a method to seamlessly connect all rail segments based on the railway clearance restrictions, and a seamless rail alignment is formed sequentially from the middle tunnel section to both ends. Finally, based on the rail alignment and the track clearance coordinate system, different types of clearance frames are introduced for intrusion operation with the tunnel section to realize the tunnel clearance inspection. By taking the Shuanghekou Tunnel of the Chengdu–Kunming Railway as an example, when the clearance inspection is carried out by the method mentioned herein, its precision can reach 0.03 m, and difference types of clearances can be effectively calculated. This method has a wide application prospects. PMID:28880232

  13. Clearance of the cervical spine in clinically unevaluable trauma patients.

    PubMed

    Halpern, Casey H; Milby, Andrew H; Guo, Wensheng; Schuster, James M; Gracias, Vicente H; Stein, Sherman C

    2010-08-15

    Meta-analytic costeffectiveness analysis. Our goal was to compare the results of different management strategies for trauma patients in whom the cervical spine was not clinically evaluable due to impaired consciousness, endotracheal intubation, or painful distracting injuries. We performed a structured literature review related to cervical spine trauma, radiographic clearance techniques (plain radiography, flexion/extension, CT, and MRI), and complications associated with semirigid collar use. Meta-analytic techniques were used to pool data from multiple sources to calculate pooled mean estimates of sensitivities and specificities of imaging techniques for cervical spinal clearance, rates of complications from various clearance strategies and from empirical use of semirigid collars. A decision analysis model was used to compare outcomes and costs among these strategies. Slightly more than 7.5% of patients who are clinically unevaluable have cervical spine injuries, and 42% of these injuries are associated with spinal instability. Sensitivity of plain radiography or fluoroscopy for spinal clearance was 57% (95% CI: 57%-60%). Sensitivities for CT and MRI alone were 83% (82%-84%) and 87% (84%-89%), respectively. Complications associated with collar use ranged from 1.3% (2 days) to 7.1% (10 days) but were usually minor and short-lived. Quadriplegia resulting from spinal instability missed by a clearance test had enormous impacts on longevity, quality of life, and costs. These impacts overshadowed the effects of prolonged collar application, even when the incidence of quadriplegia was extremely low. As currently used, neuroimaging studies for cervical spinal clearance in clinically unevaluable patients are not cost-effective compared with empirical immobilization in a semirigid collar.

  14. Sport and active recreation injuries in Australia: evidence from emergency department presentations

    PubMed Central

    Finch, C.; Valuri, G.; Ozanne-Smith, J.

    1998-01-01

    OBJECTIVE: Despite the rise in specialist clinical services for the management of sports and active recreation injury, many patients attend hospital emergency departments for treatment. The purpose of this study was to describe sports injury cases presented to selected hospital emergency departments around Australia for the period 1989-1993. METHODS: Routinely collected emergency department injury presentation data from the Australian National Injury Surveillance Unit were examined. Data on 98,040 sports and active recreation emergency department presentations were analysed. Sports and active recreation activities were ranked according to frequency of presentation. Relative proportions of injury type and body region injured were determined. Data are presented separately for children (<15 years of age) and adults (>15 years of age). RESULTS: Among the 10 activities that most commonly led to a sports or active recreation injury presentation for all ages were cycling, Australian football, basketball, soccer, cricket, netball, and rugby. For children, injuries were also commonly associated with roller skating/blading, skateboarding, and trampolining. Hockey, martial arts, and dancing injuries were frequent in adults. Most sporting injuries occurred during organised competition or practice whereas the active recreation injuries occurred in a variety of settings. Fractures, strains, and sprains, particularly to the lower and upper extremities, were common types of injury. CONCLUSION: The rich, but nevertheless limited, information available about sports and active recreation injuries from data collected in emergency departments indicates that these activities are a common context for injury at the community level in Australia. 


 PMID:9773170

  15. Shape memory alloy adaptive control of gas turbine engine compressor blade tip clearance

    NASA Astrophysics Data System (ADS)

    Schetky, Lawrence M.; Steinetz, Bruce M.

    1998-06-01

    The ambient air ingested through the inlet of a gas turbine is first compressed by an axial compressor followed by further compression in a centrifugal compressor and then fed into the combustion chamber where ignition and expansion take place to produce the engine thrust. The axial compressor typically has five or more stages which consist of revolving blades and stators and the overall performance of the turbine is strongly affected by the compressor efficiency. When the turbine is turned on, to accommodate the rapid initial increase in the compressor blade length due to centrifugal force, the cold turbine has a built in clearance between the turbine blade tip and the casing. As the turbine reached its operating temperature there is a further increase in the blade length due to thermal expansion and, at the same time, the diameter of the casing increases. The net result is that when these various components have reached their equilibrium temperatures, the initial cold build clearance is reduced, but there remains a residual clearance. The magnitude of this clearance has a direct effect on the compressor efficiency and can be stated as: Δη/Δ CLR equals 0.5 where η is efficiency and CLR is the tip clearance. The concept of adaptive tip clearance control is based on the ability of a shape memory alloy ring to shrink to a predetermined diameter when heated to the temperature of a particular stage, and thus reducing the tip clearance. The ring is fabricated from a CuAlNi shape memory alloy and is mounted in the casing so as to be coaxial with the rotating blades of the particular stage. When cold, the ring dimensions are such as to provide the required cold build clearance, but when at operating temperature the reduced diameter creates a very small tip clearance. The clearance provided by this concept is much smaller than the clearance normally obtained for a turbine of the size being studied.

  16. Effect of Internal Clearance on Load Distribution and Life of Radially Loaded Ball and Roller Bearings

    NASA Technical Reports Server (NTRS)

    Oswald, Fred B.; Zaretsky, Erwin V.; Poplawski, Joseph V.

    2012-01-01

    The effect of internal clearance on radially loaded deepgroove ball and cylindrical roller bearing load distribution and fatigue life was determined for four clearance groups defined in the bearing standards. The analysis was extended to negative clearance (interference) conditions to produce a curve of life factor versus internal clearance. Rolling-element loads can be optimized and bearing life maximized for a small negative operating clearance. Life declines gradually with positive clearance and rapidly with increasing negative clearance. Relationships were found between bearing life and internal clearance as a function of ball or roller diameter, adjusted for load. Results are presented as life factors for radially loaded bearings independent of bearing size or applied load. In addition, a modified Stribeck Equation is presented that relates the maximum rolling-element load to internal bearing clearance.

  17. Circulatory Support with Venoarterial ECMO Unsuccessful in Aiding Endogenous Diltiazem Clearance after Overdose.

    PubMed

    Frazee, Erin N; Lee, Sarah J; Kalimullah, Ejaaz A; Personett, Heather A; Nelson, Darlene R

    2014-01-01

    Introduction. In cardiovascular collapse from diltiazem poisoning, extracorporeal membrane oxygenation (ECMO) may offer circulatory support sufficient to preserve endogenous hepatic drug clearance. Little is known about patient outcomes and diltiazem toxicokinetics in this setting. Case Report. A 36-year-old woman with a history of myocardial bridging syndrome presented with chest pain for which she self-medicated with 2.4 g of sustained release diltiazem over the course of 8 hours. Hemodynamics and mentation were satisfactory on presentation, but precipitously deteriorated after ICU transfer. She was given fluids, calcium, vasopressors, glucagon, high-dose insulin, and lipid emulsion. Due to circulatory collapse and multiorgan failure including ischemic hepatopathy, she underwent transvenous pacing and emergent initiation of venoarterial ECMO. The peak diltiazem level was 13150 ng/mL (normal 100-200 ng/mL) and it remained elevated at 6340 ng/mL at hour 90. Unfortunately, the patient developed multiple complications which resulted in her death on ICU day 9. Conclusion. This case describes the unsuccessful use of ECMO for diltiazem intoxication. Although past reports suggest that support with ECMO may facilitate endogenous diltiazem clearance, it may be dependent on preserved hepatic function at the time of cannulation, a factor not present in this case.

  18. Nanoparticle-macrophage interactions: A balance between clearance and cell-specific targeting

    PubMed Central

    Rattan, Rahul; Bhattacharjee, Somnath; Zong, Hong; Swain, Corban; Siddiqui, Muneeb A.; Visovatti, Scott H.; Kanthi, Yogendra; Desai, Sajani; Pinsky, David J.; Goonewardena, Sascha N.

    2017-01-01

    The surface properties of nanoparticles (NPs) are a major factor that influences how these nanomaterials interact with biological systems. Interactions between NPs and macrophages of the reticuloendothelial system (RES) can reduce the efficacy of NP diagnostics and therapeutics. Traditionally, to limit NP clearance by the RES system, the NP surface is neutralized with molecules like poly(ethylene glycol) (PEG) which are known to resist protein adsorption and RES clearance. Unfortunately, PEG modification is not without drawbacks including difficulties with the synthesis and associations with immune reactions. To overcome some of these obstacles, we neutralized the NP surface by acetylation and compared this modification to PEGylation for RES clearance and tumor-specific targeting. We found that acetylation was comparable to PEGylation in reducing RES clearance. Additionally, we found that dendrimer acetylation did not impact folic acid (FA)-mediated targeting of tumor cells whereas PEG surface modification reduced the targeting ability of the NP. These results clarify the impact of different NP surface modifications on RES clearance and cell-specific targeting and provide insights into the design of more effective NPs. PMID:28705434

  19. CO2 clearance by membrane lungs.

    PubMed

    Sun, Liqun; Kaesler, Andreas; Fernando, Piyumindri; Thompson, Alex J; Toomasian, John M; Bartlett, Robert H

    2018-05-01

    Commercial membrane lungs are designed to transfer a specific amount of oxygen per unit of venous blood flow. Membrane lungs are much more efficient at removing CO 2 than adding oxygen, but the range of CO 2 transfer is rarely reported. Commercial membrane lungs were studied with the goal of evaluating CO 2 removal capacity. CO 2 removal was measured in 4 commercial membrane lungs under standardized conditions. CO 2 clearance can be greater than 4 times that of oxygen at a given blood flow when the gas to blood flow ratio is elevated to 4:1 or 8:1. The CO 2 clearance was less dependent on surface area and configuration than oxygen transfer. Any ECMO system can be used for selective CO 2 removal.

  20. 75 FR 70341 - Agency Information Collection Activities: Emergency Clearance Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-17

    ... Method of information collection respondents response response annual burden (minutes) (hours) Personal Interview (SSA field office) 147,000 1 30 73,500 Paper Form (mailed) 39,000 1 45 29,250 Totals 186,000 102...

  1. 77 FR 22831 - Agency Information Collection Activities: Emergency Clearance Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-17

    ... as job searches and interviews, progress reviews, and changes in ticket status. ENs can be private... SSA requires ENs to submit multiple types of TTW program and participant information, resulting in 13... web portal, and because of manpower limitations we will be facing in the upcoming months, SSA is...

  2. Nicotinamide treatment ameliorates the course of experimental colitis mediated by enhanced neutrophil-specific antibacterial clearance.

    PubMed

    Bettenworth, Dominik; Nowacki, Tobias M; Ross, Matthias; Kyme, Pierre; Schwammbach, Daniela; Kerstiens, Linda; Thoennissen, Gabriela B; Bokemeyer, Carsten; Hengst, Karin; Berdel, Wolfgang E; Heidemann, Jan; Thoennissen, Nils H

    2014-07-01

    In previous studies, we could show that the B vitamin nicotinamide (NAM) enhanced antimicrobial activity of neutrophils. Here, we assessed the effects of NAM in two models of experimental colitis. Colitis was induced in C57BL/6 mice either by oral infection with Citrobacter rodentium or by DSS (dextran sodium sulphate) administration, and animals were systemically treated with NAM. Ex vivo bacterial clearance was assessed in murine and human whole blood, as well as isolated human neutrophils. In C. rodentium-induced colitis, NAM treatment resulted in markedly decreased systemic bacterial invasion, histological damage and increased fecal clearance of C. rodentium by up to 600-fold. In contrast, NAM had no effect when administered to neutrophil-depleted mice. Ex vivo stimulation of isolated human neutrophils, as well as murine and human whole blood with NAM led to increased clearance of C. rodentium and enhanced expression of antimicrobial peptides in neutrophils. Moreover, NAM treatment significantly ameliorated the course of DSS colitis, as assessed by body weight, histological damage and myeloperoxidase activity. Pharmacological application of NAM mediates beneficial effects in bacterial and chemically induced colitis. Future studies are needed to explore the clinical potential of NAM in the context of intestinal bacterial infections and human inflammatory bowel disease (IBD). © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. 77 FR 50546 - Agency Information Collection: Emergency Submission for OMB Review (CEPACT (Center for Evaluation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-21

    ... emergency clearance is being requested for information needed to focus on patient experiences with and views... leadership in health care quality. This will be done to evaluate the effectiveness of various types of care...

  4. Long-term clearance from small airways in subjects with ciliary dysfunction.

    PubMed

    Lindström, Maria; Falk, Rolf; Hjelte, Lena; Philipson, Klas; Svartengren, Magnus

    2006-05-20

    The objective of this study was to investigate if long-term clearance from small airways is dependent on normal ciliary function. Six young adults with primary ciliary dyskinesia (PCD) inhaled 111 Indium labelled Teflon particles of 4.2 microm geometric and 6.2 microm aerodynamic diameter with an extremely slow inhalation flow, 0.05 L/s. The inhalation method deposits particles mainly in the small conducting airways. Lung retention was measured immediately after inhalation and at four occasions up to 21 days after inhalation. Results were compared with data from ten healthy controls. For additional comparison three of the PCD subjects also inhaled the test particles with normal inhalation flow, 0.5 L/s, providing a more central deposition. The lung retention at 24 h in % of lung deposition (Ret24) was higher (p < 0.001) in the PCD subjects, 79 % (95% Confidence Interval, 67.6;90.6), compared to 49% (42.3;55.5) in the healthy controls. There was a significant clearance after 24 h both in the PCD subjects and in the healthy controls with equivalent clearance. The mean Ret24 with slow inhalation flow was 73.9 +/- 1.9% compared to 68.9 +/- 7.5% with normal inhalation flow in the three PCD subjects exposed twice. During day 7-21 the three PCD subjects exposed twice cleared 9% with normal flow, probably representing predominantly alveolar clearance, compared to 19% with slow inhalation flow, probably representing mainly small airway clearance. This study shows that despite ciliary dysfunction, clearance continues in the small airways beyond 24 h. There are apparently additional clearance mechanisms present in the small airways.

  5. Predictive factors of spontaneous CMV DNAemia clearance in kidney transplantation.

    PubMed

    Noble, Johan; Gatault, Philippe; Sautenet, Bénédicte; Gaudy-Graffin, Catherine; Beby-Defaux, Agnes; Thierry, Antoine; Essig, Marie; Halimi, Jean-Michel; Munteanu, Eliza; Alain, Sophie; Buchler, Matthias

    Cytomegalovirus (CMV) infection occurs frequently after solid organ transplantation. Therapeutic strategies, in particular when to start a curative treatment, has not yet been defined. The purpose of this study was to assess predictive factors associated with spontaneous clearance of CMV DNAemia in kidney transplant recipients. All kidney recipients of a single center were recruited. Patients with at least one positive CMV DNAemia during the first year post transplantation were included in our analysis. Whole blood CMV PCR was performed using Abbott ® RealTime CMV, calibrated according to WHO standards and expressed in log10 IU/ml (Detection = 1.79 IU log10/ml). Post transplantation, prophylaxis (valganciclovir) was given for 3 months for CMV positive recipients (R+) and 6 months for CMV positive donors giving to seronegative recipients (D + R-). Clinical and biological symptoms attributable to CMV were collected. We defined as spontaneous CMV clearance undetectable DNAemia before the fourth follow up without treatment. Results were expressed as mean ± SD. Results were prospectively assessed in a French multicenter validation cohort. Between 05/2012 and 05/2015, 95 patients had at least one positive CMV DNAemia. Thirty-six (37.8%) had spontaneous undetectable DNAemia. Fifty-nine patients had non-spontaneous CMV clearance. ROC analysis showed that an initial CMV DNAemia <2.75 log10/IU/mL was optimal to predict CMV spontaneous clearance. On multivariate analysis, factors associated with spontaneous CMV clearance were initial PCR level lower than 2.75 log10/IU/ml (OR = 33.8, 95% CI [7.1-160.0]), and absence of CMV DNAemia increase of more than 1 log10 between two analyses (OR = 128.0, 95% CI [11.9-1368.0]). Clinical and biological abnormalities were not associated CMV DNAemia spontaneous clearance. Observations made for the principal cohort were validated in an independent cohort of 49 kidney transplanted patients. Initial standardized

  6. Levitation force of small clearance superconductor-magnet system under non-coaxial condition

    NASA Astrophysics Data System (ADS)

    Xu, Jimin; Jin, Yingze; Yuan, Xiaoyang; Miao, Xusheng

    2017-03-01

    A novel superconducting tilting-pad bearing was proposed for the advanced research of reusable liquid hydrogen turbopump in liquid rocket. The bearing is a combination of superconducting magnetic bearing and hydrodynamic fluid-film bearing. Since the viscosity of cryogenic fuel to activate superconducting state and form hydrodynamic fluid-film is very low, bearing clearance will be very small. This study focuses on the investigation of superconducting levitation force in this kind of small clearance superconductor-magnet system. Based on Bean critical state model and three-dimensional finite element method, an analysis method is presented to obtain the levitation force under such situation. Since the complicated operational conditions and structural arrangement for application in liquid rocket, center lines of bulk superconductor and magnet rotor will usually be in non-coaxial state. Superconducting levitation forces in axial direction and radial direction under non-coaxial situation are also analyzed by the presented method.

  7. 14 CFR 25.925 - Propeller clearance.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... attitude, whichever is most critical. In addition, there must be positive clearance between the propeller and the ground when in the level takeoff attitude with the critical tire(s) completely deflated and...

  8. 30 CFR 56.11005 - Fixed ladder anchorage and toe clearance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Fixed ladder anchorage and toe clearance. 56.11005 Section 56.11005 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... Travelways § 56.11005 Fixed ladder anchorage and toe clearance. Fixed ladders shall be anchored securely and...

  9. 30 CFR 56.11005 - Fixed ladder anchorage and toe clearance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fixed ladder anchorage and toe clearance. 56.11005 Section 56.11005 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... Travelways § 56.11005 Fixed ladder anchorage and toe clearance. Fixed ladders shall be anchored securely and...

  10. 30 CFR 56.11005 - Fixed ladder anchorage and toe clearance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Fixed ladder anchorage and toe clearance. 56.11005 Section 56.11005 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... Travelways § 56.11005 Fixed ladder anchorage and toe clearance. Fixed ladders shall be anchored securely and...

  11. 30 CFR 56.11005 - Fixed ladder anchorage and toe clearance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Fixed ladder anchorage and toe clearance. 56.11005 Section 56.11005 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... Travelways § 56.11005 Fixed ladder anchorage and toe clearance. Fixed ladders shall be anchored securely and...

  12. 30 CFR 56.11005 - Fixed ladder anchorage and toe clearance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fixed ladder anchorage and toe clearance. 56.11005 Section 56.11005 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... Travelways § 56.11005 Fixed ladder anchorage and toe clearance. Fixed ladders shall be anchored securely and...

  13. Impairment of paravascular clearance pathways in the aging brain.

    PubMed

    Kress, Benjamin T; Iliff, Jeffrey J; Xia, Maosheng; Wang, Minghuan; Wei, Helen S; Zeppenfeld, Douglas; Xie, Lulu; Kang, Hongyi; Xu, Qiwu; Liew, Jason A; Plog, Benjamin A; Ding, Fengfei; Deane, Rashid; Nedergaard, Maiken

    2014-12-01

    In the brain, protein waste removal is partly performed by paravascular pathways that facilitate convective exchange of water and soluble contents between cerebrospinal fluid (CSF) and interstitial fluid (ISF). Several lines of evidence suggest that bulk flow drainage via the glymphatic system is driven by cerebrovascular pulsation, and is dependent on astroglial water channels that line paravascular CSF pathways. The objective of this study was to evaluate whether the efficiency of CSF-ISF exchange and interstitial solute clearance is impaired in the aging brain. CSF-ISF exchange was evaluated by in vivo and ex vivo fluorescence microscopy and interstitial solute clearance was evaluated by radiotracer clearance assays in young (2-3 months), middle-aged (10-12 months), and old (18-20 months) wild-type mice. The relationship between age-related changes in the expression of the astrocytic water channel aquaporin-4 (AQP4) and changes in glymphatic pathway function was evaluated by immunofluorescence. Advancing age was associated with a dramatic decline in the efficiency of exchange between the subarachnoid CSF and the brain parenchyma. Relative to the young, clearance of intraparenchymally injected amyloid-β was impaired by 40% in the old mice. A 27% reduction in the vessel wall pulsatility of intracortical arterioles and widespread loss of perivascular AQP4 polarization along the penetrating arteries accompanied the decline in CSF-ISF exchange. We propose that impaired glymphatic clearance contributes to cognitive decline among the elderly and may represent a novel therapeutic target for the treatment of neurodegenerative diseases associated with accumulation of misfolded protein aggregates. © 2014 American Neurological Association.

  14. Clearance kinetics and tissue distribution of aggregated human serum IgA in rats.

    PubMed Central

    Bogers, W M; Gorter, A; Stuurman, M E; Van Es, L A; Daha, M R

    1989-01-01

    In the present study the clearance kinetics and tissue distribution of human polyclonal heat-aggregated serum IgA (AIgA) of different sizes in rats was studied after intravenous administration of 125I-AIgA. The 125I-AIgA of different sizes disappeared from the circulation in a biphasic manner with an initial rapid half-life (T1/2) and a second slower T1/2. The first T1/2 was related to the size of the 125I-AIgA: high molecular weight (MW) 125I-AIgA was cleared much faster than 125I-AIgA with a low MW. Relatively more degradation products were observed in blood when high MW 125I-AIgA were injected as compared to low MW 125I-AIgA. The AIgA were mainly taken up by the liver. Eight minutes after injection of high MW 125I-AIgA, 90% of the injected dose was found in the liver, whereas less than 2% was detected in the spleen. Very little activity was detectable in other organs, such as lungs, heart and kidneys. In the present study 1-3% of the injected 125I-AIgA were found in the bile. Analysis of this material revealed that low MW 125I-AIgA were transported more efficiently to the bile than high MW 125I-AIgA. To obtain more insight into the receptors involved in the clearance of 125I-AIgA, rats were pretreated with ovalbumin or asialofetuin. The clearance of 125I-AIgA of different sizes was inhibited when rats were pretreated with asialofetuin. Pretreatment with ovalbumin had no effect on the clearance rates of 125I-AIgA. These results suggest a role for carbohydrate receptors, which recognize glycoprotein-containing galactose terminal residues on Kupffer cells, in the clearance of 125I-AIgA. PMID:2473956

  15. The effects of 2100-MHz radiofrequency radiation on nasal mucosa and mucociliary clearance in rats.

    PubMed

    Aydoğan, Filiz; Aydın, Emine; Koca, Gökhan; Özgür, Elçin; Atilla, Pergin; Tüzüner, Arzu; Demirci, Şule; Tomruk, Arin; Öztürk, Göknur Güler; Seyhan, Nesrin; Korkmaz, Meliha; Müftüoğlu, Sevda; Samim, Ethem Erdal

    2015-07-01

    Nasal mucociliary clearance has an important role in voiding the airways from inhaled foreign substances. This activity could be disturbed by environmental factors such as radiofrequency radiation. The aim of the present study was to investigate short-term and relatively long-term effects of 2100-MHz radiofrequency radiation emitted by a generator, simulating a 3G-mobile phone, on the nasal septal mucosa and mucociliary clearance in rats. Thirty Wistar albino rats were divided into 4 groups. There were 6 rats in Group A and Group B, which served as the control groups (10-day and 40-day groups, respectively). Groups C (10-day exposure) and D (40-day exposure) were both composed of 9 rats; they comprised the radiofrequency radiation exposure groups. The rats in groups C and D were exposed to 2100-MHz radiofrequency radiation emitted by a generator, simulating a 3G-mobile phone, 6 hours/day, for 10 or 40 days, respectively. After exposure, nasal mucociliary clearance was measured by rhinoscintigraphy. After euthanization, the nasal septa of the animals were removed, and tissue samples of the nasal mucosa were examined using a transmission electron microscope. The differences in mucociliary clearances between groups A and C, groups B and D, and groups C and D were found to be statistically significant (p = 0.005, p < 0.001, p < 0.001, respectively). Although there were no histopathological abnormalities in the control groups, the exposure groups showed a number of degenerated and apoptotic cells, ciliary disorganization and ciliary loss in the epithelial cells, epithelial metaplasia, alteration of normal chromatin distribution and karyolysis in nuclei, changes in the basal cells, and lymphocytic infiltration. The histopathological changes were more severe in group D. Radiofrequency radiation at 2100 MHz damaged the nasal septal mucosa, and disturbed the mucociliary clearance. Ciliary disorganization and ciliary loss in the epithelial cells resulted in deterioration of

  16. Hepatic macrophage complement receptor clearance function following injury.

    PubMed

    Cuddy, B G; Loegering, D J; Blumenstock, F A; Shah, D M

    1986-03-01

    Previous work has demonstrated that in vivo hepatic macrophage complement receptor clearance function is depressed following thermal injury. The present study was carried out to determine if complement receptor function depression is associated with other states of depressed host defense. Hepatic complement receptor clearance function was determined from the hepatic uptake of rat erythrocytes coated with antierythrocyte IgM (EIgM) in rats. Receptor function was determined following cannulation of a carotid artery, laparotomy plus enterotomy, hemorrhagic shock, trauma, thermal injury, acute bacteremia, acute endotoxemia, and injection of erythrocyte stroma, gelatinized lipid emulsion, or colloidal carbon. Hepatic uptake of EIgM was depressed following each of these experimental interventions except arterial cannulation. This effect was shown not to be due to a decrease in hepatic blood flow or depletion of complement and was therefore due to a depression in hepatic macrophage complement receptor clearance function. Thus, impairment of hepatic macrophage complement receptor function is associated with several states of depressed host defense.

  17. 76 FR 2198 - Agency Information Collection: Emergency Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-12

    ...(j)(1)). An emergency focus group clearance is being requested in regards to the Veterans' Suicide... are experiencing mental health crises and provide confident and trustworthy counseling. To be... groups with Veterans and their families, community organizations, and other important and influential...

  18. Experimental Study of Unshrouded Impeller Pump Stage Sensitivity to Tip Clearance

    NASA Technical Reports Server (NTRS)

    Williams, Robert W.; Zoladz, Thomas; Storey, Anne K.; Skelley, Stephen E.

    2002-01-01

    This viewgraph presentation provides information on an experiment. Its objective is to experimentally determine unshrouded impeller performance sensitivity to tip clearance. The experiment included: Determining impeller efficiency at scaled operating conditions in water at MSFC's Pump Test Equipment (PTE) Facility; Testing unshrouded impeller at three different tip clearances; Testing each tip clearance configuration at on- and off-design conditions, and collecting unsteady- and steady-state data in each configuration; Determining impeller efficiency directly using drive line torquemeter and pump inlet and exit total pressure measurements.

  19. Simple geometric algorithms to aid in clearance management for robotic mechanisms

    NASA Technical Reports Server (NTRS)

    Copeland, E. L.; Ray, L. D.; Peticolas, J. D.

    1981-01-01

    Global geometric shapes such as lines, planes, circles, spheres, cylinders, and the associated computational algorithms which provide relatively inexpensive estimates of minimum spatial clearance for safe operations were selected. The Space Shuttle, remote manipulator system, and the Power Extension Package are used as an example. Robotic mechanisms operate in quarters limited by external structures and the problem of clearance is often of considerable interest. Safe clearance management is simple and suited to real time calculation, whereas contact prediction requires more precision, sophistication, and computational overhead.

  20. 14 CFR 103.23 - Flight visibility and cloud clearance requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Flight visibility and cloud clearance... Flight visibility and cloud clearance requirements. No person may operate an ultralight vehicle when the flight visibility or distance from clouds is less than that in the table found below. All operations in...