Sample records for additional tests performed

  1. 40 CFR 63.504 - Additional requirements for performance testing.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Additional requirements for performance... Additional requirements for performance testing. (a) Performance testing shall be conducted in accordance.... Sections 63.484 through 63.501 also contain specific testing requirements. (1) Performance tests shall be...

  2. Effects of increasing the PSA cutoff to perform additional biomarker tests before prostate biopsy.

    PubMed

    Nordström, Tobias; Adolfsson, Jan; Grönberg, Henrik; Eklund, Martin

    2017-10-03

    Multi-step testing might enhance performance of the prostate cancer diagnostic pipeline. Using PSA >1 ng/ml for first-line risk stratification and the Stockholm 3 Model (S3M) blood-test >10% risk of Gleason Score > 7 prostate cancer to inform biopsy decisions has been suggested. We aimed to determine the effects of changing the PSA cutoff to perform reflex testing with S3M and the subsequent S3M cutoff to recommend prostate biopsy while maintaining the sensitivity to detect Gleason Score ≥ 7 prostate cancer. We used data from the prospective, population-based, paired, diagnostic Stockholm 3 (STHLM3) study with participants invited by date of birth from the Swedish Population Register during 2012-2014. All participants underwent testing with PSA and S3M (a combination of plasma protein biomarkers [PSA, free PSA, intact PSA, hK2, MSMB, MIC1], genetic polymorphisms, and clinical variables [age, family, history, previous prostate biopsy, prostate exam]). Of 47,688 men in the STHLM3 main study, we used data from 3133 men with S3M >10% and prostate biopsy data. Logistic regression models were used to calculate prostate cancer detection rates and proportion saved biopsies. 44.2%, 62.5% and 67.9% of the participants had PSA <1, <1.5 and <1.7 ng/ml, respectively. Increasing the PSA cut-off for additional work-up from 1 ng/ml to 1.5 ng/ml would thus save 18.3% of the performed tests, 4.9% of the biopsies and 1.3% (10/765) of Gleason Grade ≥ 7 cancers would be un-detected. By lowering the S3M cutoff to recommend biopsy, sensitivity to high-grade prostate cancer can be restored, to the cost of increasing the number of performed biopsies modestly. The sensitivity to detect prostate cancer can be maintained when using different PSA cutoffs to perform additional testing. Biomarker cut-offs have implications on number of tests and prostate biopsies performed. A PSA cutoff of 1.5 ng/ml to perform additional testing such as the S3M test might be considered. ISRCTN

  3. The teratology testing of food additives.

    PubMed

    Barrow, Paul C; Spézia, François

    2013-01-01

    The developmental and reproductive toxicity testing (including teratogenicity) of new foods and food additives is performed worldwide according to the guidelines given in the FDA Redbook. These studies are not required for substances that are generally recognized as safe, according to the FDA inventory. The anticipated cumulated human exposure level above which developmental or reproduction studies are required depends on the structure-alert category. For food additives of concern, both developmental (prenatal) and reproduction (multigeneration) studies are required. The developmental studies are performed in two species, usually the rat and the rabbit. The reproduction study is generally performed in the rat. The two rat studies are preferably combined into a single experimental design, if possible. The test methods described in the FDA Redbook are similar to those specified by the OECD for the reproductive toxicity testing of chemicals.

  4. Performance testing of asphalt concrete containing crumb rubber modifier and warm mix additives

    NASA Astrophysics Data System (ADS)

    Ikpugha, Omo John

    Utilisation of scrap tire has been achieved through the production of crumb rubber modified binders and rubberised asphalt concrete. Terminal and field blended asphalt rubbers have been developed through the wet process to incorporate crumb rubber into the asphalt binder. Warm mix asphalt technologies have been developed to curb the problem associated with the processing and production of such crumb rubber modified binders. Also the lowered production and compaction temperatures associated with warm mix additives suggests the possibility of moisture retention in the mix, which can lead to moisture damage. Conventional moisture sensitivity tests have not effectively discriminated good and poor mixes, due to the difficulty of simulating field moisture damage mechanisms. This study was carried out to investigate performance properties of crumb rubber modified asphalt concrete, using commercial warm mix asphalt technology. Commonly utilised asphalt mixtures in North America such as dense graded and stone mastic asphalt were used in this study. Uniaxial Cyclic Compression Testing (UCCT) was used to measure permanent deformation at high temperatures. Indirect Tensile Testing (IDT) was used to investigate low temperature performance. Moisture Induced Sensitivity Testing (MiST) was proposed to be an effective method for detecting the susceptibility of asphalt mixtures to moisture damage, as it incorporates major field stripping mechanisms. Sonnewarm(TM), Sasobit(TM) and Evotherm(TM) additives improved the resistance to permanent deformation of dense graded mixes at a loading rate of 0.5 percent by weight of the binder. Polymer modified mixtures showed superior resistance to permanent deformation compared to asphalt rubber in all mix types. Rediset(TM) WMX improves low temperature properties of dense graded mixes at 0.5 percent loading on the asphalt cement. Rediset LQ and Rediset WMX showed good anti stripping properties at 0.5 percent loading on the asphalt cement. The

  5. An Additive Manufacturing Test Artifact

    PubMed Central

    Moylan, Shawn; Slotwinski, John; Cooke, April; Jurrens, Kevin; Donmez, M Alkan

    2014-01-01

    A test artifact, intended for standardization, is proposed for the purpose of evaluating the performance of additive manufacturing (AM) systems. A thorough analysis of previously proposed AM test artifacts as well as experience with machining test artifacts have inspired the design of the proposed test artifact. This new artifact is designed to provide a characterization of the capabilities and limitations of an AM system, as well as to allow system improvement by linking specific errors measured in the test artifact to specific sources in the AM system. The proposed test artifact has been built in multiple materials using multiple AM technologies. The results of several of the builds are discussed, demonstrating how the measurement results can be used to characterize and improve a specific AM system. PMID:26601039

  6. Diesel fuel detergent additive performance and assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vincent, M.W.; Papachristos, M.J.; Williams, D.

    Diesel fuel detergent additives are increasingly linked with high quality automotive diesel fuels. Both in Europe and in the USA, field problems associated with fuel injector coking or fouling have been experienced. In Europe indirect injection (IDI) light duty engines used in passenger cars were affected, while in the USA, a direct injection (DI) engine in heavy duty truck applications experienced field problems. In both cases, a fuel additive detergent performance test has evolved using an engine linked with the original field problem, although engine design modifications employed by the manufacturers have ensured improved operation in service. Increasing awareness ofmore » the potential for injector nozzle coking to cause deterioration in engine performance is coupled with a need to meet ever more stringent exhaust emissions legislation. These two requirements indicate that the use of detergency additives will continue to be associated with high quality diesel fuels. The paper examines detergency performance evaluated in a range of IDI and DI engines and correlates performance in the two most widely recognised test engines, namely the Peugeot 1.9 litre IDI, and Cummins L10 DI engines. 17 refs., 18 figs., 5 tabs.« less

  7. Surface-specific additive manufacturing test artefacts

    NASA Astrophysics Data System (ADS)

    Townsend, Andrew; Racasan, Radu; Blunt, Liam

    2018-06-01

    Many test artefact designs have been proposed for use with additive manufacturing (AM) systems. These test artefacts have primarily been designed for the evaluation of AM form and dimensional performance. A series of surface-specific measurement test artefacts designed for use in the verification of AM manufacturing processes are proposed here. Surface-specific test artefacts can be made more compact because they do not require the large dimensions needed for accurate dimensional and form measurements. The series of three test artefacts are designed to provide comprehensive information pertaining to the manufactured surface. Measurement possibilities include deviation analysis, surface texture parameter data generation, sub-surface analysis, layer step analysis and build resolution comparison. The test artefacts are designed to provide easy access for measurement using conventional surface measurement techniques, for example, focus variation microscopy, stylus profilometry, confocal microscopy and scanning electron microscopy. Additionally, the test artefacts may be simply visually inspected as a comparative tool, giving a fast indication of process variation between builds. The three test artefacts are small enough to be included in every build and include built-in manufacturing traceability information, making them a convenient physical record of the build.

  8. The development of a performance-enhancing additive for vapor-compression heat pumps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grzyll, L.R.; Scaringe, R.P.; Gottschlich, J.M.

    1997-12-31

    This paper describes the testing results of a vapor-compression heat pump operating with HFC-134a refrigerant and a performance-enhancing additive. Preliminary bench-top testing of this additive, when added to polyolester (POE) lubricant and HFC-134a refrigerant, showed surprising enhancements to system COP. To further investigate this finding, the authors designed and fabricated a vapor-compression heat pump test stand for the 3--5 ton range. The authors investigated the effect of different concentrations of this additive on various system performance parameters such as cooling capacity, compressor power requirement, pressure ratio, compressor pressure difference, compressor isentropic efficiency, refrigerant flow rate, and heat exchanger performance. Themore » authors investigated various heat source and heat sink conditions to simulate air-conditioning and heat pump operating conditions. To investigate the effect of this additive on compressor lubrication and life, the authors performed compressor life tests (with scroll and reciprocating compressors), and had lubrication wear tests performed with various concentrations of the additive in the POE lubricant.« less

  9. DSN system performance test software

    NASA Technical Reports Server (NTRS)

    Martin, M.

    1978-01-01

    The system performance test software is currently being modified to include additional capabilities and enhancements. Additional software programs are currently being developed for the Command Store and Forward System and the Automatic Total Recall System. The test executive is the main program. It controls the input and output of the individual test programs by routing data blocks and operator directives to those programs. It also processes data block dump requests from the operator.

  10. 14 CFR 27.927 - Additional tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Additional tests. 27.927 Section 27.927... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 27.927 Additional tests. (a) Any additional dynamic, endurance, and operational tests, and vibratory investigations necessary to determine...

  11. 14 CFR 27.927 - Additional tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Additional tests. 27.927 Section 27.927... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 27.927 Additional tests. (a) Any additional dynamic, endurance, and operational tests, and vibratory investigations necessary to determine...

  12. 14 CFR 29.927 - Additional tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Additional tests. 29.927 Section 29.927... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 29.927 Additional tests. (a) Any additional dynamic, endurance, and operational tests, and vibratory investigations necessary to determine...

  13. 14 CFR 27.927 - Additional tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Additional tests. 27.927 Section 27.927... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 27.927 Additional tests. (a) Any additional dynamic, endurance, and operational tests, and vibratory investigations necessary to determine...

  14. 14 CFR 29.927 - Additional tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Additional tests. 29.927 Section 29.927... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 29.927 Additional tests. (a) Any additional dynamic, endurance, and operational tests, and vibratory investigations necessary to determine...

  15. 14 CFR 29.927 - Additional tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Additional tests. 29.927 Section 29.927... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 29.927 Additional tests. (a) Any additional dynamic, endurance, and operational tests, and vibratory investigations necessary to determine...

  16. Additive Manufacturing Thermal Performance Testing of Single Channel GRCop-84 SLM Components

    NASA Technical Reports Server (NTRS)

    Garcia, Chance P.; Cross, Matthew

    2014-01-01

    The surface finish found on components manufactured by sinter laser manufacturing (SLM) is rougher (0.013 - 0.0006 inches) than parts made using traditional fabrication methods. Internal features and passages built into SLM components do not readily allow for roughness reduction processes. Alternatively, engineering literature suggests that the roughness of a surface can enhance thermal performance within a pressure drop regime. To further investigate the thermal performance of SLM fabricated pieces, several GRCop-84 SLM single channel components were tested using a thermal conduction rig at MSFC. A 20 kW power source running at 25% duty cycle and 25% power level applied heat to each component while varying water flow rates between 2.1 - 6.2 gallons/min (GPM) at a supply pressure of 550 to 700 psi. Each test was allowed to reach quasi-steady state conditions where pressure, temperature, and thermal imaging data were recorded. Presented in this work are the heat transfer responses compared to a traditional machined OHFC Copper test section. An analytical thermal model was constructed to anchor theoretical models with the empirical data.

  17. 21 CFR 660.54 - Potency tests, specificity tests, tests for heterospecific antibodies, and additional tests for...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... heterospecific antibodies, and additional tests for nonspecific properties. 660.54 Section 660.54 Food and Drugs..., specificity tests, tests for heterospecific antibodies, and additional tests for nonspecific properties. The...) Specificity tests, tests for heterospecific antibodies, and additional tests for nonspecific properties. [50...

  18. Basophil activation test with food additives in chronic urticaria patients.

    PubMed

    Kang, Min-Gyu; Song, Woo-Jung; Park, Han-Ki; Lim, Kyung-Hwan; Kim, Su-Jung; Lee, Suh-Young; Kim, Sae-Hoon; Cho, Sang-Heon; Min, Kyung-Up; Chang, Yoon-Seok

    2014-01-01

    The role of food additives in chronic urticaria (CU) is still under investigation. In this study, we aimed to explore the association between food additives and CU by using the basophil activation test (BAT). The BAT using 15 common food additives was performed for 15 patients with CU who had a history of recurrent urticarial aggravation following intake of various foods without a definite food-specific IgE. Of the 15 patients studied, two (13.3%) showed positive BAT results for one of the tested food additives. One patient responded to monosodium glutamate, showing 18.7% of CD203c-positive basophils. Another patient showed a positive BAT result to sodium benzoate. Both patients had clinical correlations with the agents, which were partly determined by elimination diets. The present study suggested that at least a small proportion of patients with CU had symptoms associated with food additives. The results may suggest the potential utility of the BAT to identity the role of food additives in CU.

  19. On Bayesian Testing of Additive Conjoint Measurement Axioms Using Synthetic Likelihood

    ERIC Educational Resources Information Center

    Karabatsos, George

    2017-01-01

    This article introduces a Bayesian method for testing the axioms of additive conjoint measurement. The method is based on an importance sampling algorithm that performs likelihood-free, approximate Bayesian inference using a synthetic likelihood to overcome the analytical intractability of this testing problem. This new method improves upon…

  20. Basophil Activation Test with Food Additives in Chronic Urticaria Patients

    PubMed Central

    Kang, Min-Gyu; Song, Woo-Jung; Park, Han-Ki; Lim, Kyung-Hwan; Kim, Su-Jung; Lee, Suh-Young; Kim, Sae-Hoon; Cho, Sang-Heon; Min, Kyung-Up

    2014-01-01

    The role of food additives in chronic urticaria (CU) is still under investigation. In this study, we aimed to explore the association between food additives and CU by using the basophil activation test (BAT). The BAT using 15 common food additives was performed for 15 patients with CU who had a history of recurrent urticarial aggravation following intake of various foods without a definite food-specific IgE. Of the 15 patients studied, two (13.3%) showed positive BAT results for one of the tested food additives. One patient responded to monosodium glutamate, showing 18.7% of CD203c-positive basophils. Another patient showed a positive BAT result to sodium benzoate. Both patients had clinical correlations with the agents, which were partly determined by elimination diets. The present study suggested that at least a small proportion of patients with CU had symptoms associated with food additives. The results may suggest the potential utility of the BAT to identity the role of food additives in CU. PMID:24527415

  1. Verification System: First System-Wide Performance Test

    NASA Astrophysics Data System (ADS)

    Chernobay, I.; Zerbo, L.

    2006-05-01

    System-wide performance tests are essential for the development, testing and evaluation of individual components of the verification system. In addition to evaluating global readiness it helps establishing the practical and financial requirements for eventual operations. The first system-wide performance test (SPT1) was conducted in three phases: - A preparatory phase in May-June 2004 - A performance testing phase in April-June 2005 - An evaluation phase in the last half of 2005. The preparatory phase was developmental in nature. The main objectives for the performance testing phase included establishment of performance baseline under current provisional mode of operation (CTBT/PC- 19/1/Annex II, CTBT/WGB-21/1), examination of established requirements and procedures for operation and maintenance. To establish a system-wide performance baseline the system configuration was fixed for April-May 2005. The third month (June 2005) was used for implementation of 21 test case scenarios to examine either particular operational procedures or the response of the system components to the failures simulated under controlled conditions. A total of 163 stations and 5 certified radionuclide laboratories of International Monitoring System (IMS) participated in the performance testing phase - about 50% of the eventual IMS network. 156 IMS facilities and 40 National Data Centres (NDCs) were connected to the International Data Centre (IDC) via Global Communication Infrastructure (GCI) communication links. In addition, 12 legacy stations in the auxiliary seismic network sent data to the IDC over the Internet. During the performance testing phase, the IDC produced all required products, analysed more than 6100 seismic events and 1700 radionuclide spectra. Performance of all system elements was documented and analysed. IDC products were compared with results of data processing at the NDCs. On the basis of statistics and information collected during the SPT1 a system-wide performance

  2. 40 CFR 63.1352 - Additional test methods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 12 2014-07-01 2014-07-01 false Additional test methods. 63.1352... Monitoring and Compliance Provisions § 63.1352 Additional test methods. (a) If you are conducting tests to... manufacturing facilities, for use in applicability determinations under § 63.1340, you may use Method 320 or...

  3. 21 CFR 660.54 - Potency tests, specificity tests, tests for heterospecific antibodies, and additional tests for...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 7 2012-04-01 2012-04-01 false Potency tests, specificity tests, tests for heterospecific antibodies, and additional tests for nonspecific properties. 660.54 Section 660.54 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR...

  4. 21 CFR 660.54 - Potency tests, specificity tests, tests for heterospecific antibodies, and additional tests for...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Potency tests, specificity tests, tests for heterospecific antibodies, and additional tests for nonspecific properties. 660.54 Section 660.54 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR...

  5. 21 CFR 660.54 - Potency tests, specificity tests, tests for heterospecific antibodies, and additional tests for...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 7 2013-04-01 2013-04-01 false Potency tests, specificity tests, tests for heterospecific antibodies, and additional tests for nonspecific properties. 660.54 Section 660.54 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR...

  6. 21 CFR 660.54 - Potency tests, specificity tests, tests for heterospecific antibodies, and additional tests for...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 7 2014-04-01 2014-04-01 false Potency tests, specificity tests, tests for heterospecific antibodies, and additional tests for nonspecific properties. 660.54 Section 660.54 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR...

  7. Performance tests.

    PubMed Central

    Wetherell, A

    1996-01-01

    This paper discusses the use of psychological performance tests to assess the effects of environmental stressors. The large number and the variety of performance tests are illustrated, and the differences between performance tests and other psychological tests are described in terms of their design, construction, use, and purpose. The stressor emphasis is on the effects of drugs since that is where most performance tests have found their main application, although other stressors, e.g., fatigue, toxic chemicals, are mentioned where appropriate. Diazepam is used as an example. There is no particular performance emphasis since the tests are intended to have wide applicability. However, vehicle-driving performance is discussed because it has been the subject of a great deal of research and is probably one of the most important areas of application. Performance tests are discussed in terms of the four main underlying models--factor analysis, general information processing, multiple resource and strategy models, and processing-stage models--and in terms of their psychometric properties--sensitivity, reliability, and content, criterion, construct, and face validity. Some test taxonomies are presented. Standardization is also discussed with reference to the reaction time, mathematical processing, memory search, spatial processing, unstable tracking, verbal processing, and dual task tests used in the AGARD STRES battery. Some comments on measurement strengths and appropriate study designs and methods are included. PMID:9182033

  8. Effort, symptom validity testing, performance validity testing and traumatic brain injury.

    PubMed

    Bigler, Erin D

    2014-01-01

    To understand the neurocognitive effects of brain injury, valid neuropsychological test findings are paramount. This review examines the research on what has been referred to a symptom validity testing (SVT). Above a designated cut-score signifies a 'passing' SVT performance which is likely the best indicator of valid neuropsychological test findings. Likewise, substantially below cut-point performance that nears chance or is at chance signifies invalid test performance. Significantly below chance is the sine qua non neuropsychological indicator for malingering. However, the interpretative problems with SVT performance below the cut-point yet far above chance are substantial, as pointed out in this review. This intermediate, border-zone performance on SVT measures is where substantial interpretative challenges exist. Case studies are used to highlight the many areas where additional research is needed. Historical perspectives are reviewed along with the neurobiology of effort. Reasons why performance validity testing (PVT) may be better than the SVT term are reviewed. Advances in neuroimaging techniques may be key in better understanding the meaning of border zone SVT failure. The review demonstrates the problems with rigidity in interpretation with established cut-scores. A better understanding of how certain types of neurological, neuropsychiatric and/or even test conditions may affect SVT performance is needed.

  9. Advanced Manufacturing Technologies (AMT): Additive Manufactured Hot Fire Planning and Testing in GRC Cell 32 Project

    NASA Technical Reports Server (NTRS)

    Fikes, John C.

    2014-01-01

    The objective of this project is to hot fire test an additively manufactured thrust chamber assembly TCA (injector and thrust chamber). GRC will install the additively manufactured Inconel 625 injector, two additively manufactured (SLM) water cooled Cu-Cr thrust chamber barrels and one additively manufactured (SLM) water cooled Cu-Cr thrust chamber nozzle on the test stand in Cell 32 and perform hot fire testing of the integrated TCA.

  10. Electrochemical performance of tris(2-chloroethyl) phosphate as a flame-retarding additive for lithium-ion batteries

    NASA Astrophysics Data System (ADS)

    Shim, Eun-Gi; Park, In-Jun; Nam, Tae-Heum; Kim, Jung-Gu; Kim, Hyun-Soo; Moon, Seong-In

    2010-08-01

    We studied tris(2-chloroethyl) phosphate (TCEP) as a potential flame-retarding additive and its effect on the electrochemical cell performance of lithium-ion battery electrolytes. The electrochemical cell performance of additive-containing electrolytes in combination with a cell comprised of a LiCoO2 cathode and a mesocarbon microbeads anode was tested in coin cells. The cyclic voltammetry results show that the oxidation potential of TCEP-containing electrolyte is about 5.1 V (vs. Li/Li+). A cell with TCEP has a better electrochemical cell performance than a cell without TCEP in an initial charge and discharge test. In a cycling test, a cell containing a TCEP-containing electrolyte has a greater discharge capacity and better capacity retention than a TCEP-free electrolyte after cycling. The results confirm the promising potential of TCEP as a flame-retarding additive and as a means of improving the electrochemical cell performance of lithium-ion batteries.

  11. Understanding protocol performance: impact of test performance.

    PubMed

    Turner, Robert G

    2013-01-01

    This is the second of two articles that examine the factors that determine protocol performance. The objective of these articles is to provide a general understanding of protocol performance that can be used to estimate performance, establish limits on performance, decide if a protocol is justified, and ultimately select a protocol. The first article was concerned with protocol criterion and test correlation. It demonstrated the advantages and disadvantages of different criterion when all tests had the same performance. It also examined the impact of increasing test correlation on protocol performance and the characteristics of the different criteria. To examine the impact on protocol performance when individual tests in a protocol have different performance. This is evaluated for different criteria and test correlations. The results of the two articles are combined and summarized. A mathematical model is used to calculate protocol performance for different protocol criteria and test correlations when there are small to large variations in the performance of individual tests in the protocol. The performance of the individual tests that make up a protocol has a significant impact on the performance of the protocol. As expected, the better the performance of the individual tests, the better the performance of the protocol. Many of the characteristics of the different criteria are relatively independent of the variation in the performance of the individual tests. However, increasing test variation degrades some criteria advantages and causes a new disadvantage to appear. This negative impact increases as test variation increases and as more tests are added to the protocol. Best protocol performance is obtained when individual tests are uncorrelated and have the same performance. In general, the greater the variation in the performance of tests in the protocol, the more detrimental this variation is to protocol performance. Since this negative impact is increased as

  12. Automated microbial metabolism laboratory. [design of advanced labeled release experiment based on single addition of soil and multiple sequential additions of media into test chambers

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The design and rationale of an advanced labeled release experiment based on single addition of soil and multiple sequential additions of media into each of four test chambers are outlined. The feasibility for multiple addition tests was established and various details of the methodology were studied. The four chamber battery of tests include: (1) determination of the effect of various atmospheric gases and selection of that gas which produces an optimum response; (2) determination of the effect of incubation temperature and selection of the optimum temperature for performing Martian biochemical tests; (3) sterile soil is dosed with a battery of C-14 labeled substrates and subjected to experimental temperature range; and (4) determination of the possible inhibitory effects of water on Martian organisms is performed initially by dosing with 0.01 ml and 0.5 ml of medium, respectively. A series of specifically labeled substrates are then added to obtain patterns in metabolic 14CO2 (C-14)O2 evolution.

  13. New ways to analyze word generation performance in brain injury: A systematic review and meta-analysis of additional performance measures.

    PubMed

    Thiele, Kristina; Quinting, Jana Marie; Stenneken, Prisca

    2016-09-01

    The investigation of word generation performance is an accepted, widely used, and well-established method for examining cognitive, language, or communication impairment due to brain damage. The performance measure traditionally applied in the investigation of word generation is the number of correct responses. Previous studies, however, have suggested that this measure does not capture all potentially relevant aspects of word generation performance and hence its underlying processes, so that its analytical and explanatory power of word generation performance might be rather limited. Therefore, additional qualitative or quantitative performance measures have been introduced to gain information that goes beyond the deficit and allows for therapeutic implications. We undertook a systematic review and meta-analysis of original research that focused on the application of additional measures of word generation performance in adult clinical populations with acquired brain injury. Word generation tasks are an integral part of many different tests, but only few use additional performance measures in addition to the number of correct responses in the analysis of word generation performance. Additional measures, which showed increased or similar diagnostic utility relative to the traditional performance measure, regarded clustering and switching, error types, and temporal characteristics. The potential of additional performance measures is not yet fully exhausted in patients with brain injury. The temporal measure of response latencies in particular is not adequately represented, though it may be a reliable measure especially for identifying subtle impairments. Unfortunately, there is no general consensus as of yet on which additional measures are best suited to characterizing word generation performance. Further research is needed to specify the additional parameters that are best qualified for identifying and characterizing impaired word generation performance.

  14. Additive and Multiplicative Effects of Working Memory and Test Anxiety on Mathematics Performance in Grade 3 Students

    ERIC Educational Resources Information Center

    Korhonen, Johan; Nyroos, Mikaela; Jonsson, Bert; Eklöf, Hanna

    2018-01-01

    The aim of this study was to investigate the interplay between test anxiety and working memory (WM) on mathematics performance in younger children. A sample of 624 grade 3 students completed a test battery consisting of a test anxiety scale, WM tasks and the Swedish national examination in mathematics for grade 3. The main effects of test anxiety…

  15. On Bayesian Testing of Additive Conjoint Measurement Axioms Using Synthetic Likelihood.

    PubMed

    Karabatsos, George

    2018-06-01

    This article introduces a Bayesian method for testing the axioms of additive conjoint measurement. The method is based on an importance sampling algorithm that performs likelihood-free, approximate Bayesian inference using a synthetic likelihood to overcome the analytical intractability of this testing problem. This new method improves upon previous methods because it provides an omnibus test of the entire hierarchy of cancellation axioms, beyond double cancellation. It does so while accounting for the posterior uncertainty that is inherent in the empirical orderings that are implied by these axioms, together. The new method is illustrated through a test of the cancellation axioms on a classic survey data set, and through the analysis of simulated data.

  16. 49 CFR 199.111 - Retention of samples and additional testing.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.111 Retention of samples and additional testing. (a... other than the unauthorized use of a prohibited drug, and if timely additional testing is requested by... 49 Transportation 3 2011-10-01 2011-10-01 false Retention of samples and additional testing. 199...

  17. 49 CFR 199.111 - Retention of samples and additional testing.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.111 Retention of samples and additional testing. (a... other than the unauthorized use of a prohibited drug, and if timely additional testing is requested by... 49 Transportation 3 2013-10-01 2013-10-01 false Retention of samples and additional testing. 199...

  18. 49 CFR 199.111 - Retention of samples and additional testing.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.111 Retention of samples and additional testing. (a... other than the unauthorized use of a prohibited drug, and if timely additional testing is requested by... 49 Transportation 3 2012-10-01 2012-10-01 false Retention of samples and additional testing. 199...

  19. 49 CFR 199.111 - Retention of samples and additional testing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.111 Retention of samples and additional testing. (a... other than the unauthorized use of a prohibited drug, and if timely additional testing is requested by... 49 Transportation 3 2010-10-01 2010-10-01 false Retention of samples and additional testing. 199...

  20. 49 CFR 199.111 - Retention of samples and additional testing.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... SAFETY DRUG AND ALCOHOL TESTING Drug Testing § 199.111 Retention of samples and additional testing. (a... other than the unauthorized use of a prohibited drug, and if timely additional testing is requested by... 49 Transportation 3 2014-10-01 2014-10-01 false Retention of samples and additional testing. 199...

  1. Research on Hartmann test for progressive addition lenses

    NASA Astrophysics Data System (ADS)

    Qin, Lin-ling; Yu, Jing-chi

    2009-05-01

    Recently, in the world some growing-up measurements for Progressive addition lenses and relevant equipments have been developed. They are single point measurement, moiré deflectometry, Ronchi test techniques. Hartmann test for Progressive addition lenses is proposed in the article. The measurement principle of Hartmann test for ophthalmic lenses and the power compensation of off-axis rays are introduced. The experimental setup used to test lenses is put forward. For experimental test, a spatial filter is used for selecting a clean Gaussian beam; a collimating lens with focal distance f =300 mm is used to produce collimated beam. The Hartmann plate with a square array of holes separated at 2 mm is selected. The selection of laser and CCD camera is critical to the accuracy of experiment and the image processing algorithm. The spot patterns from CCD are obtained from the experimental tests. The power distribution map for lenses can be obtained by image processing in theory. The results indicate that Hartmann test for Progressive addition lenses is convenient and feasible; also its structure is simple.

  2. 46 CFR 176.840 - Additional tests and inspections.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Additional tests and inspections. 176.840 Section 176.840 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) INSPECTION AND CERTIFICATION Material Inspections § 176.840 Additional tests and inspections. The cognizant OCMI may require that a...

  3. 46 CFR 176.840 - Additional tests and inspections.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Additional tests and inspections. 176.840 Section 176.840 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) INSPECTION AND CERTIFICATION Material Inspections § 176.840 Additional tests and inspections. The cognizant OCMI may require that a...

  4. Performance Test on Polymer Waste Form - 12137

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Se Yup

    Polymer solidification was attempted to produce stable waste form for the boric acid concentrates and the dewatered spent resins. The polymer mixture was directly injected into the mold or drum which was packed with the boric acid concentrates and the dewatered spent resins, respectively. The waste form was produced by entirely curing the polymer mixture. A series of performance tests was conducted including compressive strength test, water immersion test, leach test, thermal stability test, irradiation stability test and biodegradation stability test for the polymer waste forms. From the results of the performance tests for the polymer waste forms, it ismore » believed that the polymer waste form is very stable and can satisfy the acceptance criteria for permanent disposal. At present, performance tests with full scale polymer waste forms are being carried out in order to obtain qualification certificate by the regulatory institute in Korea. Polymer waste forms were prepared with the surrogate of boric acid concentrates and the surrogate of spent ion exchange resins respectively. Waste forms were also made in lab scale and in full scale. Lab. scale waste forms were directly subjected to a series of the performance tests. In the case of full scale waste form, the test specimens for the performance test were taken from a part of waste form by coring. A series of performance tests was conducted including compressive strength test, thermal stability test, irradiation stability test and biodegradation stability test, water immersion test, leach test, and free standing water for the polymer waste forms. In addition, a fire resistance test was performed on the waste forms by the requirement of the regulatory institute in Korea. Every polymer waste forms containing the boric acid concentrates and the spent ion exchange resins had exhibited excellent structural integrity of more than 27.58 MPa (4,000 psi) of compressive strength. On thermal stability testing

  5. Cascade Distiller System Performance Testing Interim Results

    NASA Technical Reports Server (NTRS)

    Callahan, Michael R.; Pensinger, Stuart; Sargusingh, Miriam J.

    2014-01-01

    The Cascade Distillation System (CDS) is a rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. Based upon the results of the 2009 distillation comparison test (DCT) and recommendations of the expert panel, the Advanced Exploration Systems (AES) Water Recovery Project (WRP) project advanced the technology by increasing reliability of the system through redesign of bearing assemblies and improved rotor dynamics. In addition, the project improved the CDS power efficiency by optimizing the thermoelectric heat pump (TeHP) and heat exchanger design. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell d International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades as compared to previous system performance. The system was challenged with Solution 1 from the NASA Exploration Life Support (ELS) distillation comparison testing performed in 2009. Solution 1 consisted of a mixed stream containing human-generated urine and humidity condensate. A secondary objective of this testing is to evaluate the performance of the CDS as compared to the state of the art Distillation Assembly (DA) used in the ISS Urine Processor Assembly (UPA). This was done by challenging the system with ISS analog waste streams. This paper details the results of the AES WRP CDS performance testing.

  6. Humor and Anxiety: Effects on Class Test Performance.

    ERIC Educational Resources Information Center

    Townsend, Michael A. R.; Mahoney, Peggy

    The roles of humor and anxiety in test performance were investigated. Measures of trait anxiety, state anxiety and achievement were obtained on a sample of undergraduate students; the A-Trait and A-State scales of the State-Trait Anxiety Inventory were used. Half of the students received additional humorous items in the achievement test. The…

  7. Performance testing accountability measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oldham, R.D.; Mitchell, W.G.; Spaletto, M.I.

    The New Brunswick Laboratory (NBL) provides assessment support to the DOE Operations Offices in the area of Material Control and Accountability (MC and A). During surveys of facilities, the Operations Offices have begun to request from NBL either assistance in providing materials for performance testing of accountability measurements or both materials and personnel to do performance testing. To meet these needs, NBL has developed measurement and measurement control performance test procedures and materials. The present NBL repertoire of performance tests include the following: (1) mass measurement performance testing procedures using calibrated and traceable test weights, (2) uranium elemental concentration (assay)more » measurement performance tests which use ampulated solutions of normal uranyl nitrate containing approximately 7 milligrams of uranium per gram of solution, and (3) uranium isotopic measurement performance tests which use ampulated uranyl nitrate solutions with enrichments ranging from 4% to 90% U-235. The preparation, characterization, and packaging of the uranium isotopic and assay performance test materials were done in cooperation with the NBL Safeguards Measurements Evaluation Program since these materials can be used for both purposes.« less

  8. Field Testing of a Wet FGD Additive for Enhanced Mercury Control - Pilot-Scale Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gary M. Blythe

    2006-03-01

    This Topical Report summarizes progress on Cooperative Agreement DE-FC26-04NT42309, ''Field Testing of a Wet FGD Additive.'' The objective of the project is to demonstrate the use of a flue gas desulfurization (FGD) additive, Degussa Corporation's TMT-15, to prevent the reemissions of elemental mercury (Hg{sup 0}) in flue gas exiting wet FGD systems on coal-fired boilers. Furthermore, the project intends to demonstrate that the additive can be used to precipitate most of the mercury (Hg) removed in the wet FGD system as a fine TMT salt that can be separated from the FGD liquor and bulk solid byproducts for separate disposal.more » The project will conduct pilot and full-scale tests of the TMT-15 additive in wet FGD absorbers. The tests are intended to determine required additive dosage requirements to prevent Hg{sup 0} reemissions and to separate mercury from the normal FGD byproducts for three coal types: Texas lignite/Power River Basin (PRB) coal blend, high-sulfur Eastern bituminous coal, and low-sulfur Eastern bituminous coal. The project team consists of URS Group, Inc., EPRI, TXU Generation Company LP, Southern Company, and Degussa Corporation. TXU Generation has provided the Texas lignite/PRB co-fired test site for pilot FGD tests, Monticello Steam Electric Station Unit 3. Southern Company is providing the low-sulfur Eastern bituminous coal host site for wet scrubbing tests, as well as the pilot and full-scale jet bubbling reactor (JBR) FGD systems to be tested. A third utility, to be named later, will provide the high-sulfur Eastern bituminous coal full-scale FGD test site. Degussa Corporation is providing the TMT-15 additive and technical support to the test program. The project is being conducted in six tasks. Of the six project tasks, Task 1 involves project planning and Task 6 involves management and reporting. The other four tasks involve field testing on FGD systems, either at pilot or full scale. The four tasks include: Task 2 - Pilot Additive

  9. Shield evaluation and performance testing at the USMB`s Strategic Structures Testing Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barczak, T.M.; Gearhart, D.F.

    1996-12-31

    Historically, shield performance testing is conducted by the support manufacturers at European facilities. The U.S. Bureau of Mines (USBM) has conducted extensive research in shield Mechanics and is now opening its Strategic Structures Testing (SST) Laboratory to the mining industry for shield performance testing. The SST Laboratory provides unique shield testing capabilities using the Mine Roof Simulator (MRS) load frame. The MRS provides realistic and cost-effective shield evaluation by combining both vertical and horizontal loading into a single load cycle; whereas, several load cycles would be required to obtain this loading in a static frame. In addition to these advantages,more » the USBM acts as an independent research organization to provide an unbiased assessment of shield performance. This paper describes the USBM`s shield testing program that is designed specifically to simulate in-service mining conditions using the unique the capabilities of the SST Laboratory.« less

  10. The effect of hydrophilicity of graphene oxide as additive towards performance of polysulfone membrane

    NASA Astrophysics Data System (ADS)

    Jamalludin, Mohd Riduan; Harun, Zawati; Zakaria, M. S.; Rahim, Wan Mohd Faizal Wan Abd; Khor, C. Y.; Rosli, M. U.; Ishak, Muhammad Ikman; Nawi, M. A. M.; Shahrin, Suhaimi

    2017-09-01

    This study investigates the effect of hydrophilicity of graphene oxide as additive towards properties and performance on polysulfone (PSf) membrane. A polysulfone (PSf) membrane containing graphene oxide (GO) with different content was prepared via phase inversion technique. Characterization on the fabricated membrane were water contact angle measurement, porosity and mean pore size. The effects of PSf/GO were further investigated in terms of permeation test, rejection test and antifouling test. Based on the result obtained, PSf membrane incorporating with GO additive shows better capability to permeate more water compared to unfilled PSf membrane. The PSf/GO membrane were able to increase the permeate rate rapidly with the highest value is given by sample 4 (consist of 0.7 g of GO) at 571.78 J/m2h. Furthermore, water contact angle confirmed the hydrophilicity of this membrane at 62°. The transmembrane fouling activity showed that GO embedded in PSf membrane has improved tremendously. In addition, this study revealed that 0.7g of GO had the highest permeation test, rejection test and antifouling test.

  11. Tough, High-Performance, Thermoplastic Addition Polymers

    NASA Technical Reports Server (NTRS)

    Pater, Ruth H.; Proctor, K. Mason; Gleason, John; Morgan, Cassandra; Partos, Richard

    1991-01-01

    Series of addition-type thermoplastics (ATT's) exhibit useful properties. Because of their addition curing and linear structure, ATT polymers have toughness, like thermoplastics, and easily processed, like thermosets. Work undertaken to develop chemical reaction forming stable aromatic rings in backbone of ATT polymer, combining high-temperature performance and thermo-oxidative stability with toughness and easy processibility, and minimizing or eliminating necessity for tradeoffs among properties often observed in conventional polymer syntheses.

  12. 14 CFR 29.927 - Additional tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... runs of from 1 to 5 minutes duration each at 60 to 80 percent of maximum continuous speed. (2... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... additional dynamic, endurance, and operational tests, and vibratory investigations necessary to determine...

  13. The influence of cellulose nanocrystal additions on the performance of cement paste

    Treesearch

    Yizheng Cao; Pablo Zavaterri; Jeff Youngblood; Robert Moon; Jason Weiss

    2015-01-01

    The influence of cellulose nanocrystals (CNCs) addition on the performance of cement paste was investigated. Our mechanical tests show an increase in the flexural strength of approximately 30% with only 0.2% volume of CNCs with respect to cement. Isothermal calorimetry (IC) and thermogravimetric analysis (TGA) show that the degree of hydration (DOH) of the cement paste...

  14. Improvements and Performance of the Fermilab Solenoid Test Facility

    DOE PAGES

    Orris, Darryl; Arnold, Don; Brandt, Jeffrey; ...

    2017-06-01

    Here, the Solenoid Test Facility at Fermilab was built using a large vacuum vessel for testing of conduction-cooled superconducting solenoid magnets, and was first used to determine the performance of the MICE Coupling Coil. The facility was modified recently to enable testing of solenoid magnets for the Mu2e experiment, which operate at much higher current than the Coupling Coil. One pair of low current conduction-cooled copper and NbTi leads was replaced with two pairs of 10 kA HTS leads cooled by heat exchange with liquid nitrogen and liquid helium. The new design, with additional control and monitoring capability, also providesmore » helium cooling of the superconducting magnet leads by conduction. A high current power supply with energy extraction was added, and several improvements to the quench protection and characterization system were made. Here we present details of these changes and report on performance results from a test of the Mu2e prototype Transport Solenoid (TS) module. Progress on additional improvements in preparation for production TS module testing will be presented.« less

  15. Improvements and Performance of the Fermilab Solenoid Test Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orris, Darryl; Arnold, Don; Brandt, Jeffrey

    Here, the Solenoid Test Facility at Fermilab was built using a large vacuum vessel for testing of conduction-cooled superconducting solenoid magnets, and was first used to determine the performance of the MICE Coupling Coil. The facility was modified recently to enable testing of solenoid magnets for the Mu2e experiment, which operate at much higher current than the Coupling Coil. One pair of low current conduction-cooled copper and NbTi leads was replaced with two pairs of 10 kA HTS leads cooled by heat exchange with liquid nitrogen and liquid helium. The new design, with additional control and monitoring capability, also providesmore » helium cooling of the superconducting magnet leads by conduction. A high current power supply with energy extraction was added, and several improvements to the quench protection and characterization system were made. Here we present details of these changes and report on performance results from a test of the Mu2e prototype Transport Solenoid (TS) module. Progress on additional improvements in preparation for production TS module testing will be presented.« less

  16. Comparing Student Performance on Paper-and-Pencil and Computer-Based-Tests

    ERIC Educational Resources Information Center

    Hardcastle, Joseph; Herrmann-Abell, Cari F.; DeBoer, George E.

    2017-01-01

    Can student performance on computer-based tests (CBT) and paper-and-pencil tests (PPT) be considered equivalent measures of student knowledge? States and school districts are grappling with this question, and although studies addressing this question are growing, additional research is needed. We report on the performance of students who took…

  17. Field Testing of a Wet FGD Additive for Enhanced Mercury Control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gary Blythe; MariJon Owens

    2007-12-31

    This document is the final report for DOE-NETL Cooperative Agreement DE-FC26-04NT42309, 'Field Testing of a Wet FGD Additive'. The objective of the project has been to demonstrate the use of two flue gas desulfurization (FGD) additives, Evonik Degussa Corporation's TMT-15 and Nalco Company's Nalco 8034, to prevent the re-emission of elemental mercury (Hg{sup 0}) in flue gas exiting wet FGD systems on coal-fired boilers. Furthermore, the project was intended to demonstrate whether such additives can be used to precipitate most of the mercury (Hg) removed in the wet FGD system as a fine salt that can be separated from themore » FGD liquor and bulk solid byproducts for separate disposal. The project involved pilot- and full-scale tests of the additives in wet FGD absorbers. The tests were intended to determine required additive dosages to prevent Hg{sup 0} re-emissions and to separate mercury from the normal FGD byproducts for three coal types: Texas lignite/Powder River Basin (PRB) coal blend, high-sulfur Eastern bituminous coal, and low-sulfur Eastern bituminous coal. The project team consists of URS Group, Inc., EPRI, Luminant Power (was TXU Generation Company LP), Southern Company, IPL (an AES company), Evonik Degussa Corporation and the Nalco Company. Luminant Power provided the Texas lignite/PRB co-fired test site for pilot FGD tests and project cost sharing. Southern Company provided the low-sulfur Eastern bituminous coal host site for wet scrubbing tests, the pilot- and full-scale jet bubbling reactor (JBR) FGD systems tested, and project cost sharing. IPL provided the high-sulfur Eastern bituminous coal full-scale FGD test site and cost sharing. Evonik Degussa Corporation provided the TMT-15 additive, and the Nalco Company provided the Nalco 8034 additive. Both companies also supplied technical support to the test program as in-kind cost sharing. The project was conducted in six tasks. Of the six tasks, Task 1 involved project planning and Task 6 involved

  18. Performance of warm mix asphalt with Buton natural asphalt-rubber and zeolite as an additives

    NASA Astrophysics Data System (ADS)

    Wahjuningsih, N.; Hadiwardoyo, S. P.; Sumabrata, R. J.; Anis, M.

    2018-01-01

    The aim of this research is improving of asphalt industry to decrease the fuel consumption by lowering the temperature of mixing and compacting of asphalt mixture. This technology known as Warm Mix Asphalt (WMA). Buton Natural Asphalt Rubber (BNA-R) as a function of the additive has been able to improve the performance of HMA. Zeolit has a function as an additive to lowering the mixing temperature. Aggregate composition using the composition of aggregate grading specifications for airport pavement, with the composition of BNA-R 5% and 10% and Zeolite content of 2%. The mixture have produced Resilient Modulus value by using the Universal Material Testing Apparatus (UMATTA) on optimum bitumen content each of which has been obtained from the Marshall test. Furthermore, the value of permanent deformation of asphalt mixtures tested using Wheel Tracking Machine (WTM). The result shows that BNA-R modified binder for WMA can decrease the rutting potential. The additive of local materials has improved the performance of the WMA for airport pavement with certain restrictions. From this research it is known there have been changes in the characteristics of resilient modulus and permanent deformation due to the addition of BNA-R for type of aggregate composition.

  19. Testing Game-Based Performance in Team-Handball.

    PubMed

    Wagner, Herbert; Orwat, Matthias; Hinz, Matthias; Pfusterschmied, Jürgen; Bacharach, David W; von Duvillard, Serge P; Müller, Erich

    2016-10-01

    Wagner, H, Orwat, M, Hinz, M, Pfusterschmied, J, Bacharach, DW, von Duvillard, SP, and Müller, E. Testing game-based performance in team-handball. J Strength Cond Res 30(10): 2794-2801, 2016-Team-handball is a fast paced game of defensive and offensive action that includes specific movements of jumping, passing, throwing, checking, and screening. To date and to the best of our knowledge, a game-based performance test (GBPT) for team-handball does not exist. Therefore, the aim of this study was to develop and validate such a test. Seventeen experienced team-handball players performed 2 GBPTs separated by 7 days between each test, an incremental treadmill running test, and a team-handball test game (TG) (2 × 20 minutes). Peak oxygen uptake (V[Combining Dot Above]O2peak), blood lactate concentration (BLC), heart rate (HR), sprinting time, time of offensive and defensive actions as well as running intensities, ball velocity, and jump height were measured in the game-based test. Reliability of the tests was calculated using an intraclass correlation coefficient (ICC). Additionally, we measured V[Combining Dot Above]O2peak in the incremental treadmill running test and BLC, HR, and running intensities in the team-handball TG to determine the validity of the GBPT. For the test-retest reliability, we found an ICC >0.70 for the peak BLC and HR, mean offense and defense time, as well as ball velocity that yielded an ICC >0.90 for the V[Combining Dot Above]O2peak in the GBPT. Percent walking and standing constituted 73% of total time. Moderate (18%) and high (9%) intensity running in the GBPT was similar to the team-handball TG. Our results indicated that the GBPT is a valid and reliable test to analyze team-handball performance (physiological and biomechanical variables) under conditions similar to competition.

  20. Testcross additive and dominance effects in best linear unbiased prediction of maize single-cross performance.

    PubMed

    Bernardo, R

    1996-11-01

    Best linear unbiased prediction (BLUP) has been found to be useful in maize (Zea mays L.) breeding. The advantage of including both testcross additive and dominance effects (Intralocus Model) in BLUP, rather than only testcross additive effects (Additive Model), has not been clearly demonstrated. The objective of this study was to compare the usefulness of Intralocus and Additive Models for BLUP of maize single-cross performance. Multilocation data from 1990 to 1995 were obtained from the hybrid testing program of Limagrain Genetics. Grain yield, moisture, stalk lodging, and root lodging of untested single crosses were predicted from (1) the performance of tested single crosses and (2) known genetic relationships among the parental inbreds. Correlations between predicted and observed performance were obtained with a delete-one cross-validation procedure. For the Intralocus Model, the correlations ranged from 0.50 to 0.66 for yield, 0.88 to 0.94 for moisture, 0.47 to 0.69 for stalk lodging, and 0.31 to 0.45 for root lodging. The BLUP procedure was consistently more effective with the Intralocus Model than with the Additive Model. When the Additive Model was used instead of the Intralocus Model, the reductions in the correlation were largest for root lodging (0.06-0.35), smallest for moisture (0.00-0.02), and intermediate for yield (0.02-0.06) and stalk lodging (0.02-0.08). The ratio of dominance variance (v D) to total genetic variance (v G) was highest for root lodging (0.47) and lowest for moisture (0.10). The Additive Model may be used if prior information indicates that VD for a given trait has little contribution to VG. Otherwise, the continued use of the Intralocus Model for BLUP of single-cross performance is recommended.

  1. Performance characterizations of asphalt binders and mixtures incorporating silane additive ZycoTherm

    NASA Astrophysics Data System (ADS)

    Hasan, Mohd Rosli Mohd; Hamzah, Meor Othman; Yee, Teh Sek

    2017-10-01

    Experimental works were conducted to evaluate the properties of asphalt binders and mixtures produced using a relatively new silane additive, named ZycoTherm. In this study, 0.1wt% ZycoTherm was blended with asphalt binder to enable production of asphalt mixture at lower than normal temperatures, as well as improve mix workability and compactability. Asphalt mixture performances towards pavement distresses in tropical climate region were also investigated. The properties of control asphalt binders (60/70 and 80/10 penetration grade) and asphalt binders incorporating 0.1% ZycoTherm were reported based on the penetration, softening point, rotational viscosity, complex modulus and phase angle. Subsequently, to compare the performance of asphalt mixture incorporating ZycoTherm with the control asphalt mixture, cylindrical samples were prepared at recommended temperatures and air voids depending on the binder types and test requirements. The samples were tested for indirect tensile strength (ITS), resilient modulus, dynamic creep, Hamburg wheel tracking and moisture induced damage. From compaction data using the Servopak gyratory compactor, specimen prepared using ZycoTherm exhibit higher workability and compactability compared to the conventional mixture. From the mixture performance test results, mixtures prepared with ZycoTherm showed comparable if not better performance than the control sample in terms of the resistance to moisture damage, permanent deformation and cracking.

  2. Sensitization to Food Additives in Patients with Allergy: A Study Based on Skin Test and Open Oral Challenge.

    PubMed

    Moghtaderi, Mozhgan; Hejrati, Zinatosadat; Dehghani, Zahra; Dehghani, Faranak; Kolahi, Niloofar

    2016-06-01

    There has been a great increase in the consumption of various food additives in recent years. The purpose of this study was to identify the incidence of sensitization to food additives by using skin prick test in patients with allergy and to determine the concordance rate between positive skin tests and oral challenge in hypersensitivity to additives. This cross-sectional study included 125 (female 71, male 54) patients aged 2-76 years with allergy and 100 healthy individuals. Skin tests were performed in both patient and control groups with 25 fresh food additives. Among patients with allergy, 22.4% showed positive skin test at least to one of the applied materials. Skin test was negative to all tested food additives in control group. Oral food challenge was done in 28 patients with positive skin test, in whom 9 patients showed reaction to culprit (Concordance rate=32.1%). The present study suggested that about one-third of allergic patients with positive reaction to food additives showed positive oral challenge; it may be considered the potential utility of skin test to identify the role of food additives in patients with allergy.

  3. Test anxiety and academic performance in chiropractic students.

    PubMed

    Zhang, Niu; Henderson, Charles N R

    2014-01-01

    Objective : We assessed the level of students' test anxiety, and the relationship between test anxiety and academic performance. Methods : We recruited 166 third-quarter students. The Test Anxiety Inventory (TAI) was administered to all participants. Total scores from written examinations and objective structured clinical examinations (OSCEs) were used as response variables. Results : Multiple regression analysis shows that there was a modest, but statistically significant negative correlation between TAI scores and written exam scores, but not OSCE scores. Worry and emotionality were the best predictive models for written exam scores. Mean total anxiety and emotionality scores for females were significantly higher than those for males, but not worry scores. Conclusion : Moderate-to-high test anxiety was observed in 85% of the chiropractic students examined. However, total test anxiety, as measured by the TAI score, was a very weak predictive model for written exam performance. Multiple regression analysis demonstrated that replacing total anxiety (TAI) with worry and emotionality (TAI subscales) produces a much more effective predictive model of written exam performance. Sex, age, highest current academic degree, and ethnicity contributed little additional predictive power in either regression model. Moreover, TAI scores were not found to be statistically significant predictors of physical exam skill performance, as measured by OSCEs.

  4. Metal-air cell with performance enhancing additive

    DOEpatents

    Friesen, Cody A; Buttry, Daniel

    2015-11-10

    Systems and methods drawn to an electrochemical cell comprising a low temperature ionic liquid comprising positive ions and negative ions and a performance enhancing additive added to the low temperature ionic liquid. The additive dissolves in the ionic liquid to form cations, which are coordinated with one or more negative ions forming ion complexes. The electrochemical cell also includes an air electrode configured to absorb and reduce oxygen. The ion complexes improve oxygen reduction thermodynamics and/or kinetics relative to the ionic liquid without the additive.

  5. Flight tests for the assessment of task performance and control activity

    NASA Technical Reports Server (NTRS)

    Pausder, H. J.; Hummes, D.

    1982-01-01

    The tests were performed with the helicopters BO 105 and UH-1D. Closely connected with tactical demands the six test pilots' task was to minimize the time and the altitude over the obstacles. The data reduction yields statistical evaluation parameters describing the control activity of the pilots and the achieved task performance. The results are shown in form of evaluation diagrams. Additionally dolphin tests with varied control strategy were performed to get more insight into the influence of control techniques. From these test results recommendations can be derived to emphasize the direct force control and to reduce the collective to pitch crosscoupling for the dolphin.

  6. Effects of additional interfering signals on adaptive array performance

    NASA Technical Reports Server (NTRS)

    Moses, Randolph L.

    1989-01-01

    The effects of additional interference signals on the performance of a fully adaptive array are considered. The case where the number of interference signals exceeds the number of array degrees of freedom is addressed. It is shown how performance is affected as a function of the number of array elements, the number of interference signals, and the directivity of the array antennas. By using directive auxiliary elements, the performance of the array can be as good as the performance when the additional interference signals are not present.

  7. Enhanced electrochemical performance of monoclinic WO3 thin film with redox additive aqueous electrolyte.

    PubMed

    Shinde, Pragati A; Lokhande, Vaibhav C; Chodankar, Nilesh R; Ji, Taeksoo; Kim, Jin Hyeok; Lokhande, Chandrakant D

    2016-12-01

    To achieve the highest electrochemical performance for supercapacitor, it is very essential to find out a suitable pair of an active electrode material and an electrolyte. In the present work, a simple approach is employed to enhance the supercapacitor performance of WO3 thin film. The WO3 thin film is prepared by a simple and cost effective chemical bath deposition method and its electrochemical performance is tested in conventional (H2SO4) and redox additive [H2SO4+hydroquinone (HQ)] electrolytes. Two-fold increment in electrochemical performance for WO3 thin film is observed in redox additive aqueous electrolyte compared to conventional electrolyte. WO3 thin film showed maximum specific capacitance of 725Fg(-1), energy density of 25.18Whkg(-1) at current density of 7mAcm(-2) with better cycling stability in redox electrolyte. This strategy provides the versatile way for designing the high performance energy storage devices. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Field Testing of a Wet FGD Additive for Enhanced Mercury Control - Task 5 Full-Scale Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gary Blythe; MariJon Owens

    2007-12-01

    This Topical Report summarizes progress on Cooperative Agreement DE-FC26-04NT42309, 'Field Testing of a Wet FGD Additive'. The objective of the project is to demonstrate the use of two flue gas desulfurization (FGD) additives, Evonik Degussa Corporation's TMT-15 and Nalco Company's Nalco 8034, to prevent the re-emission of elemental mercury (Hg{sup 0}) in flue gas exiting wet FGD systems on coal-fired boilers. Furthermore, the project intends to demonstrate whether the additive can be used to precipitate most of the mercury (Hg) removed in the wet FGD system as a fine salt that can be separated from the FGD liquor and bulkmore » solid byproducts for separate disposal. The project is conducting pilot- and full-scale tests of the additives in wet FGD absorbers. The tests are intended to determine required additive dosages to prevent Hg{sup 0} re-emissions and to separate mercury from the normal FGD byproducts for three coal types: Texas lignite/Powder River Basin (PRB) coal blend, high-sulfur Eastern bituminous coal, and low-sulfur Eastern bituminous coal. The project team consists of URS Group, Inc., EPRI, Luminant Power (was TXU Generation Company LP), Southern Company, IPL (an AES company), Evonik Degussa Corporation and the Nalco Company. Luminant Power has provided the Texas lignite/PRB co-fired test site for pilot FGD tests and cost sharing. Southern Company has provided the low-sulfur Eastern bituminous coal host site for wet scrubbing tests, as well as the pilot- and full-scale jet bubbling reactor (JBR) FGD systems tested. IPL provided the high-sulfur Eastern bituminous coal full-scale FGD test site and cost sharing. Evonik Degussa Corporation is providing the TMT-15 additive, and the Nalco Company is providing the Nalco 8034 additive. Both companies are also supplying technical support to the test program as in-kind cost sharing. The project is being conducted in six tasks. Of the six project tasks, Task 1 involves project planning and Task 6 involves

  9. Field Testing of a Wet FGD Additive for Enhanced Mercury Control - Task 3 Full-scale Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gary Blythe

    2007-05-01

    This Topical Report summarizes progress on Cooperative Agreement DE-FC26-04NT42309, 'Field Testing of a Wet FGD Additive'. The objective of the project is to demonstrate the use of a flue gas desulfurization (FGD) additive, Degussa Corporation's TMT-15, to prevent the reemission of elemental mercury (Hg{sup 0}) in flue gas exiting wet FGD systems on coal-fired boilers. Furthermore, the project intends to demonstrate whether the additive can be used to precipitate most of the mercury (Hg) removed in the wet FGD system as a fine TMT salt that can be separated from the FGD liquor and bulk solid byproducts for separate disposal.more » The project is conducting pilot- and full-scale tests of the TMT-15 additive in wet FGD absorbers. The tests are intended to determine required additive dosages to prevent Hg{sup 0} reemissions and to separate mercury from the normal FGD byproducts for three coal types: Texas lignite/Power River Basin (PRB) coal blend, high-sulfur Eastern bituminous coal, and low-sulfur Eastern bituminous coal. The project team consists of URS Group, Inc., EPRI, TXU Generation Company LP, Southern Company, and Degussa Corporation. TXU Generation has provided the Texas lignite/PRB cofired test site for pilot FGD tests, Monticello Steam Electric Station Unit 3. Southern Company is providing the low-sulfur Eastern bituminous coal host site for wet scrubbing tests, as well as the pilot- and full-scale jet bubbling reactor (JBR) FGD systems to be tested. IPL, an AES company, provided the high-sulfur Eastern bituminous coal full-scale FGD test site and cost sharing. Degussa Corporation is providing the TMT-15 additive and technical support to the test program as cost sharing. The project is being conducted in six tasks. Of the six project tasks, Task 1 involves project planning and Task 6 involves management and reporting. The other four tasks involve field testing on FGD systems, either at pilot or full scale. The four tasks include: Task 2 - Pilot Additive

  10. Use of proficiency test performance to determine clinical laboratory director qualifications.

    PubMed

    Howanitz, P J

    1988-04-01

    Many activities and policies influence laboratory test quality. Proficiency test results are one measure of laboratory quality, and during the past 25 years, five studies have examined the relationship of laboratory director educational requirements to proficiency test results. Data from three studies support the association between director qualifications and quality as measured by proficiency test performance, whereas no relationship was found in the other two studies. Possible reasons for conflicting results include differences in database size and demographics; in addition, proficiency test results may be inappropriate, although widely used, as the sole measure of laboratory director performance.

  11. Cost-effectiveness of additional blood screening tests in the Netherlands.

    PubMed

    Borkent-Raven, Barbara A; Janssen, Mart P; van der Poel, Cees L; Bonsel, Gouke J; van Hout, Ben A

    2012-03-01

    During the past decade, blood screening tests such as triplex nucleic acid amplification testing (NAT) and human T-cell lymphotropic virus type I or I (HTLV-I/II) antibody testing were added to existing serologic testing for hepatitis B virus (HBV), human immunodeficiency virus (HIV), and hepatitis C virus (HCV). In some low-prevalence regions these additional tests yielded disputable benefits that can be valuated by cost-effectiveness analyses (CEAs). CEAs are used to support decision making on implementation of medical technology. We present CEAs of selected additional screening tests that are not uniformly implemented in the EU. Cost-effectiveness was analyzed of: 1) HBV, HCV, and HIV triplex NAT in addition to serologic testing; 2) HTLV-I/II antibody test for all donors, for first-time donors only, and for pediatric recipients only; and 3) hepatitis A virus (HAV) for all donations. Disease progression of the studied viral infections was described in five Markov models. In the Netherlands, the incremental cost-effectiveness ratio (ICER) of triplex NAT is €5.20 million per quality-adjusted life-year (QALY) for testing minipools of six donation samples and €4.65 million/QALY for individual donation testing. The ICER for anti-HTLV-I/II is €45.2 million/QALY if testing all donations, €2.23 million/QALY if testing new donors only, and €27.0 million/QALY if testing blood products for pediatric patients only. The ICER of HAV NAT is €18.6 million/QALY. The resulting ICERs are very high, especially when compared to other health care interventions. Nevertheless, these screening tests are implemented in the Netherlands and elsewhere. Policy makers should reflect more explicit on the acceptability of costs and effects whenever additional blood screening tests are implemented. © 2011 American Association of Blood Banks.

  12. Impact of Educational Level on Performance on Auditory Processing Tests.

    PubMed

    Murphy, Cristina F B; Rabelo, Camila M; Silagi, Marcela L; Mansur, Letícia L; Schochat, Eliane

    2016-01-01

    Research has demonstrated that a higher level of education is associated with better performance on cognitive tests among middle-aged and elderly people. However, the effects of education on auditory processing skills have not yet been evaluated. Previous demonstrations of sensory-cognitive interactions in the aging process indicate the potential importance of this topic. Therefore, the primary purpose of this study was to investigate the performance of middle-aged and elderly people with different levels of formal education on auditory processing tests. A total of 177 adults with no evidence of cognitive, psychological or neurological conditions took part in the research. The participants completed a series of auditory assessments, including dichotic digit, frequency pattern and speech-in-noise tests. A working memory test was also performed to investigate the extent to which auditory processing and cognitive performance were associated. The results demonstrated positive but weak correlations between years of schooling and performance on all of the tests applied. The factor "years of schooling" was also one of the best predictors of frequency pattern and speech-in-noise test performance. Additionally, performance on the working memory, frequency pattern and dichotic digit tests was also correlated, suggesting that the influence of educational level on auditory processing performance might be associated with the cognitive demand of the auditory processing tests rather than auditory sensory aspects itself. Longitudinal research is required to investigate the causal relationship between educational level and auditory processing skills.

  13. Primer Stepper Motor Nomenclature, Definition, Performance and Recommended Test Methods

    NASA Technical Reports Server (NTRS)

    Starin, Scott; Shea, Cutter

    2014-01-01

    There has been an unfortunate lack of standardization of the terms and components of stepper motor performance, requirements definition, application of torque margin and implementation of test methods. This paper will address these inconsistencies and discuss in detail the implications of performance parameters, affects of load inertia, control electronics, operational resonances and recommended test methods. Additionally, this paper will recommend parameters for defining and specifying stepper motor actuators. A useful description of terms as well as consolidated equations and recommended requirements is included.

  14. A review of cryogenic testing performed by the thermochemical test branch, Manned Spacecraft Center in support of Apollo 13 and14

    NASA Technical Reports Server (NTRS)

    Propp, C. E.; Mcgee, J. M.

    1971-01-01

    The Apollo 13 anomaly provided considerable impetus for a variety of types of cryogenic and ignition tests. The logic of the various test program designs, the test techniques, and their final impact upon the investigation findings are described. In addition, several test programs initiated to determine the thermal performance and general performance characteristics of the redesigned Apollo 14 cryogenic storage system are presented.

  15. Efficacy of a feed-additive antibacterial combination for improving feedlot cattle performance and health.

    PubMed Central

    Gallo, G F; Berg, J L

    1995-01-01

    The effectiveness of a feed-additive antimicrobial combination for improving feedlot performance and health was tested using 4325 high-risk feeder calves randomly allocated to a control group or an experimental group. The experimental group received the conventional ration plus a feed additive containing 700 mg per head/day of chlortetracycline and sulfamethazine from arrival at the feedlot to day 56 of the feeding period. The inclusion of the feed additive to the ration significantly improved average daily gain for days 0-28 (P = 0.0163) and 0-56 (P = 0.0001), and the feed conversion for days 0-28 (P = 0.0061) and 0-56 (P = 0.0004). Additionally, the use of the feed additive significantly reduced the rate of bovine respiratory disease morbidity for days 0-28 (P = 0.0014) and 0-56 (P = 0.0001), the rate of relapses and mortality for days 0-56 (P = 0.0151 and P = 0.0209, respectively), and the rate of animals diagnosed with chronic respiratory disease for days 0-28 and 0-56 (P = 0.0009 and P = 0.0002, respectively). Performance and health improvements produced by the use of the feed additive were cost-effective. PMID:7600512

  16. Friction Stir Additive Manufacturing: Route to High Structural Performance

    NASA Astrophysics Data System (ADS)

    Palanivel, S.; Sidhar, H.; Mishra, R. S.

    2015-03-01

    Aerospace and automotive industries provide the next big opportunities for additive manufacturing. Currently, the additive industry is confronted with four major challenges that have been identified in this article. These challenges need to be addressed for the additive technologies to march into new frontiers and create additional markets. Specific potential success in the transportation sectors is dependent on the ability to manufacture complicated structures with high performance. Most of the techniques used for metal-based additive manufacturing are fusion based because of their ability to fulfill the computer-aided design to component vision. Although these techniques aid in fabrication of complex shapes, achieving high structural performance is a key problem due to the liquid-solid phase transformation. In this article, friction stir additive manufacturing (FSAM) is shown as a potential solid-state process for attaining high-performance lightweight alloys for simpler geometrical applications. To illustrate FSAM as a high-performance route, manufactured builds of Mg-4Y-3Nd and AA5083 are shown as examples. In the Mg-based alloy, an average hardness of 120 HV was achieved in the built structure and was significantly higher than that of the base material (97 HV). Similarly for the Al-based alloy, compared with the base hardness of 88 HV, the average built hardness was 104 HV. A potential application of FSAM is illustrated by taking an example of a simple stiffener assembly.

  17. Performance Test on Compression Ignition Engine by Blending Ethanol and Waste Plastic Pyrolysis Oil with Cetane Additive

    NASA Astrophysics Data System (ADS)

    Padmanabhan, S.; Ganesan, S.; Jeswin Arputhabalan, J.; Chithrala, Varun; Ganesh Bairavan, P.

    2017-05-01

    The demand for diesel fuel is higher than that of petrol throughout the world hence seeking alternative to mineral diesel is a natural choice. Alternative fuels should be easily available at lower cost, environment friendly and fulfill energy needs without modifying engine’s operational parameters. Waste to energy is the trend in the selection of alternate fuels. In this work, Waste Plastic Pyrolysis oil (WPPO), Ethanol, Diesel blend with Cetane additive has been attempted as an alternative fuel. A Twin cylinder, Direct Injection engine was used to assess the engine performance and emission characteristics of waste plastic pyrolysis oil with cetane additive. Experimental results of blended plastic fuel and diesel fuel were compared.

  18. Results of industrial tests of carbonate additive to fuel oil

    NASA Astrophysics Data System (ADS)

    Zvereva, E. R.; Dmitriev, A. V.; Shageev, M. F.; Akhmetvalieva, G. R.

    2017-08-01

    Fuel oil plays an important role in the energy balance of our country. The quality of fuel oil significantly affects the conditions of its transport, storage, and combustion; release of contaminants to atmosphere; and the operation of main and auxiliary facilities of HPPs. According to the Energy Strategy of Russia for the Period until 2030, the oil-refining ratio gradually increases; as a result, the fraction of straight-run fuel oil in heavy fuel oils consistently decreases, which leads to the worsening of performance characteristics of fuel oil. Consequently, the problem of the increase in the quality of residual fuel oil is quite topical. In this paper, it is suggested to treat fuel oil by additives during its combustion, which would provide the improvement of ecological and economic indicators of oil-fired HPPs. Advantages of this method include simplicity of implementation, low energy and capital expenses, and the possibility to use production waste as additives. In the paper, the results are presented of industrial tests of the combustion of fuel oil with the additive of dewatered carbonate sludge, which is formed during coagulation and lime treatment of environmental waters on HPPs. The design of a volume delivery device is developed for the steady additive input to the boiler air duct. The values are given for the main parameters of the condition of a TGM-84B boiler plant. The mechanism of action of dewatered carbonate sludge on sulfur oxides, which are formed during fuel oil combustion, is considered. Results of industrial tests indicate the decrease in the mass fraction of discharged sulfur oxides by 36.5%. Evaluation of the prevented damage from sulfur oxide discharged into atmospheric air shows that the combustion of the fuel oil of 100 brand using carbonate sludge as an additive (0.1 wt %) saves nearly 6 million rubles a year during environmental actions at the consumption of fuel oil of 138240 t/year.

  19. Design and Testing of a Hall Effect Thruster with Additively Manufactured Components

    NASA Astrophysics Data System (ADS)

    Hopping, Ethan

    The UAH-78AM is a low-power Hall effect thruster developed at the University of Alabama in Huntsville to study the application of low-cost additive manufacturing in the design and fabrication of Hall thrusters. The goal of this project is to assess the feasibility of using unconventional materials to produce a low-cost functioning Hall effect thruster and consider how additive manufacturing can expand the design space and provide other benefits. The thruster features channel walls and a propellant distributor that were manufactured using 3D printing with a variety of materials including ABS, ULTEM, and glazed ceramic. A version of the thruster was tested at NASA Glenn Research Center to obtain performance metrics and to validate the ability of the thruster to produce thrust and sustain a discharge. The design of the thruster and the transient performance measurements are presented here. Measured thrust ranged from 17.2 mN to 30.4 mN over a discharge power of 280 W to 520 W with an anode Isp range of 870 s to 1450 s. Temperature limitations of materials used for the channel walls and propellant distributor limit the ability to run the thruster at thermal steady-state. While the current thruster design is not yet ready for continuous operation, revisions to the device that could enable longer duration tests are discussed.

  20. Hybrid Residual Flexibility/Mass-Additive Method for Structural Dynamic Testing

    NASA Technical Reports Server (NTRS)

    Tinker, M. L.

    2003-01-01

    A large fixture was designed and constructed for modal vibration testing of International Space Station elements. This fixed-base test fixture, which weighs thousands of pounds and is anchored to a massive concrete floor, initially utilized spherical bearings and pendulum mechanisms to simulate Shuttle orbiter boundary constraints for launch of the hardware. Many difficulties were encountered during a checkout test of the common module prototype structure, mainly due to undesirable friction and excessive clearances in the test-article-to-fixture interface bearings. Measured mode shapes and frequencies were not representative of orbiter-constrained modes due to the friction and clearance effects in the bearings. As a result, a major redesign effort for the interface mechanisms was undertaken. The total cost of the fixture design, construction and checkout, and redesign was over $2 million. Because of the problems experienced with fixed-base testing, alternative free-suspension methods were studied, including the residual flexibility and mass-additive approaches. Free-suspension structural dynamics test methods utilize soft elastic bungee cords and overhead frame suspension systems that are less complex and much less expensive than fixed-base systems. The cost of free-suspension fixturing is on the order of tens of thousands of dollars as opposed to millions, for large fixed-base fixturing. In addition, free-suspension test configurations are portable, allowing modal tests to be done at sites without modal test facilities. For example, a mass-additive modal test of the ASTRO-1 Shuttle payload was done at the Kennedy Space Center launch site. In this Technical Memorandum, the mass-additive and residual flexibility test methods are described in detail. A discussion of a hybrid approach that combines the best characteristics of each method follows and is the focus of the study.

  1. Comparison of the tribology performance of nano-diesel soot and graphite particles as lubricant additives

    NASA Astrophysics Data System (ADS)

    Zhang, Zu-chuan; Cai, Zhen-bing; Peng, Jin-fang; Zhu, Min-hao

    2016-02-01

    The tribology behavior of exhaust diesel soot as a lubricant additive was investigated and then compared with that of a selection of commercial nano-graphite particles. Specifically, 0.01 wt% particles were dispersed in PAO4 oil with 1 wt% sorbitan monooleate (Span 80) as a dispersing agent, and wear tests based on the ball against plate mode were conducted at various temperatures. Different analytical techniques (e.g. transmission electron, scanning electron and infrared microscopy; energy dispersive x-ray and Raman spectroscopy; and charge measurement) were employed to characterize the chemistry and morphology of the additives and their tribology performance. The oil containing only 0.01 wt% diesel soot clearly improved wear resistance over 60 °C. In particular, at 100 °C the wear rate decreased by approximately 90% compared to the function of base oil. In the same test conditions, diesel soot exhibited better anti-wear performance than nano-graphite at high temperatures. The potential measure showed that the nano-graphite had positive charge and the diesel soot had negative charge. Electrochemical action may play an important role in the lubricant mechanisms of diesel soot and graphite as oil additives.

  2. Effects of the Addition of a Dual Task to a Supervised Physical Exercise Program on Older Adults' Cognitive Performance.

    PubMed

    Ansai, Juliana Hotta; de Andrade, Larissa Pires; de Souza Buto, Marcele Stephanie; de Vassimon Barroso, Verena; Farche, Ana Claudia Silva; Rossi, Paulo Giusti; de Medeiros Takahashi, Anielle Cristhine

    2017-04-01

    The purpose of this study was to investigate the effects of the addition of a dual task to multicomponent training on cognition of active older adults. Eighty physically active older adults were divided into an intervention group (IG) and a control group (CG). Both groups performed multicomponent training over 12 weeks. The IG simultaneously performed exercises and cognitive tasks. The Mini-Mental State Examination, the Montreal Cognitive Assessment, and the Clock Drawing Test were used for cognitive assessments. The Timed Up and Go Test associated with a cognitive task was used for dual-task assessment. Significant interactions were not observed between groups in terms of the cognitive variables or the dual-task performance. An interaction was observed only for Timed Up and Go Test performance, which was better in the CG than in the IG. Active older adults showed no improvement in cognition following the addition of the dual task to the multicomponent training.

  3. Thermal Performance Testing of EMU and CSAFE Liquid Cooling Garments

    NASA Technical Reports Server (NTRS)

    Rhodes, Richard; Bue, Grant; Hakam, Mark; Radford, Tamara

    2013-01-01

    Future exploration missions require the development of a new liquid cooling garment (LCG) that offers greater system reliability, is more comfortable, and maximizes thermal performance. To inform the development of a future LCG a thermal performance test was conducted to evaluate three factors: (1) the effect of the thermal comfort undergarment (TCU) on tactile and thermal comfort, (2) the comparable thermal performance of an CSAFE developed engineering evaluation unit (EEU) LCG, which uses a commercial-off-the-shelf (COTS) wicking garment as the base, and (3) the performance of a torso or upper body only LCG configuration to evaluate a proposed auxiliary loop configuration. To evaluate the thermal performance of each configuration a metabolic suit test was conducted, utilizing suited subjects to generate metabolic heat by walking on a treadmill at various speeds. Three (3) test subjects of similar height and weight produced a metabolic load for five tests by either resting (300-600 BTU/hr), walking at a slow pace (1200 BTU/hr), and walking at a brisk pace (2200 BTU/hr). During the test, data was collected that would allow us to track the heat transfer to the LCG and ventilation system to determine the thermal performance of the LCG configurations. Four different test configurations were tested, with one configuration tested twice. The test results show that the CSAFE EEU LCG and EMU LCG had comparable performance. The testing also showed that an auxiliary loop LCG, sized similarly to the shirt-only configuration, should provide adequate cooling for contingency scenarios. Finally, the testing showed the previous analysis that assumed a UA deterioration from the TCU was too conservative and the TCU may prove to be acceptable for future development with additional analysis and testing.

  4. Neuropsychological Test Performance in Cognitively Normal Spanish-speaking Nonagenarians with Little Education.

    PubMed

    Guerrero-Berroa, Elizabeth; Schmeidler, James; Raventos, Henriette; Valerio, Daniel; Beeri, Michal Schnaider; Carrión-Baralt, José R; Mora-Villalobos, Lara; Bolaños, Patricia; Sano, Mary; Silverman, Jeremy M

    2016-06-01

    To find associations of age, sex, and education with neuropsychological test performance in cognitively normal Spanish-speaking Costa Rican nonagenarians with little education; to provide norms; and to compare their performance with similar Puerto Ricans. For 95 Costa Ricans (90-102 years old, 0-6 years of education), multiple regression assessed associations with demographics of performance on six neuropsychological tests. Analyses of covariance compared them with 23 Puerto Ricans (90-99 years old). Younger age and being female-but not education-were associated with better performance on some neuropsychological tests, in particular episodic memory. The Puerto Ricans performed better on learning and memory tasks. In cognitively intact Spanish-speaking nonagenarians with little or no education, education did not affect test performance. Additional studies of the effect of education on cognitive performance are warranted in other samples with extremely low education or old age. National differences in performance highlight the importance of group-specific norms.

  5. Neuropsychological Test Performance in Cognitively Normal Spanish-speaking Nonagenarians with Little Education

    PubMed Central

    Schmeidler, James; Raventos, Henriette; Valerio, Daniel; Beeri, Michal Schnaider; Carrión-Baralt, José R.; Mora-Villalobos, Lara; Bolaños, Patricia; Sano, Mary; Silverman, Jeremy M.

    2016-01-01

    To find associations of age, sex, and education with neuropsychological test performance in cognitively normal Spanish-speaking Costa Rican nonagenarians with little education; to provide norms; and to compare their performance with similar Puerto Ricans. For 95 Costa Ricans (90–102 years old, 0–6 years of education), multiple regression assessed associations with demographics of performance on six neuropsychological tests. Analyses of covariance compared them with 23 Puerto Ricans (90–99 years old). Younger age and being female—but not education—were associated with better performance on some neuropsychological tests, in particular episodic memory. The Puerto Ricans performed better on learning and memory tasks. In cognitively intact Spanish-speaking nonagenarians with little or no education, education did not affect test performance. Additional studies of the effect of education on cognitive performance are warranted in other samples with extremely low education or old age. National differences in performance highlight the importance of group-specific norms. PMID:26883764

  6. The Role of Additives in Improving Performance in High Voltage Lithium-Ion Batteries with Potentiostatic Holds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tornheim, Adam; He, Meinan; Su, Chi-Cheung

    In this work, various electrolyte additives designed for enhanced performance at high voltages were evaluated with elevated temperature potentiostatic holds with LiNi0.5Co0.2Mn0.3/Li4Ti5O12 full cells to determine their effect on the high voltage stability. Of the additives investigated, many showed increased oxidation current through the 60 hour potentiostatic holds test, and adversely affected both the capacity retention and interfacial impedance. Improved high voltage performance was observed with two additives, vinylene carbonate (VC) and 1,1,2,2- tetrafluoroethyl-2,2,3,3-tetrafluoropropyl ether (TTE), which was attributed to two different mechanisms of improvement. This work challenges some conclusions in the available literature that an additive molecule that decomposesmore » on the charged cathode surface and passivates the surface against electrolyte oxidation.« less

  7. Additive value of patch testing custom epoxy materials from the workplace at the occupational disease specialty clinic in Toronto.

    PubMed

    Houle, Marie-Claude; Holness, D Linn; Dekoven, Joel; Skotnicki, Sandy

    2012-01-01

    Allergic contact dermatitis (ACD) to epoxy resins is one of the major causes of occupationally induced ACD. Testing of custom epoxy materials from the workplace is often performed to diagnose ACD. The objective of this study was to investigate the additive value of patch testing custom-made epoxy materials. We retrospectively analyzed outcomes of 24 patients who were tested to custom epoxy resin materials between January 2002 and July 2011. For 11 patients (46%), the testing of their materials from work had no additional value (negative results). For 13 patients (54%), there was an additional value of testing custom allergens. Of those, 7 patients (54%) had positive reactions to custom epoxy materials that reinforced the test results found with the commercially available allergens, and 6 (46%) patients had positive reactions only to custom epoxy materials. Therefore, for 6 patients (25%), there was a definite additive value of testing custom epoxy materials because the allergy was discovered with custom testing and not with the commercially available allergens. Because of the high percentage (54%) of patients with additive value of patch testing custom epoxy materials, we think that the inclusion of actual workplace epoxy materials should be strongly considered when patch testing patients with occupational epoxy exposure.

  8. 40 CFR 610.63 - Performance tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Performance tests. 610.63 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.63 Performance tests. The effect of a device on a vehicle's performance will be determined by performing wide-open-throttle...

  9. 40 CFR 60.8 - Performance tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Performance tests. 60.8 Section 60.8... PERFORMANCE FOR NEW STATIONARY SOURCES General Provisions § 60.8 Performance tests. (a) Except as specified in... conduct performance test(s) and furnish the Administrator a written report of the results of such...

  10. End-of-Test Performance and Wear Characterization of NASA's Evolutionary Xenon Thruster (NEXT) Long-Duration Test

    NASA Technical Reports Server (NTRS)

    Shastry, Rohit; Herman, Daniel A.; Soulas, George C.; Patterson, Michael J.

    2014-01-01

    The NASA's Evolutionary Xenon Thruster (NEXT) program is developing the next-generation solar electric ion propulsion system with significant enhancements beyond the state-of-the-art NASA Solar Electric Propulsion Technology Application Readiness (NSTAR) ion propulsion system to provide future NASA science missions with enhanced capabilities. A Long-Duration Test (LDT) was initiated in June 2005 to validate the thruster service life modeling and to quantify the thruster propellant throughput capability. Testing was recently completed in February 2014, with the thruster accumulating 51,184 hours of operation, processing 918 kg of xenon propellant, and delivering 35.5 MN-s of total impulse.As part of the test termination procedure, a comprehensive performance characterization was performed across the entire NEXT throttle table. This was performed prior to planned repairs of numerous diagnostics that had become inoperable over the course of the test. After completion of these diagnostic repairs in November 2013, a comprehensive end-of-test performance and wear characterization was performed on the test article prior to exposure to atmosphere. These data have confirmed steady thruster performance with minimal degradation as well as mitigation of numerous life limiting mechanisms encountered in the NSTAR design. Component erosion rates compare favorably to pretest predictions based on semi-empirical models used for the thruster service life assessment. Additional data relating to ion beam density profiles, facility backsputter rates, facility backpressure effects on thruster telemetry, and modulation of the neutralizer keeper current are presented as part of the end-of-test characterization. Presently the test article for the NEXT LDT has been exposed to atmosphere and placed within a clean room environment, with post-test disassembly and inspection underway.

  11. A review of the performance and structural considerations of paraffin wax hybrid rocket fuels with additives

    NASA Astrophysics Data System (ADS)

    Veale, Kirsty; Adali, Sarp; Pitot, Jean; Brooks, Michael

    2017-12-01

    Paraffin wax as a hybrid rocket fuel has not been comprehensively characterised, especially regarding the structural feasibility of the material in launch applications. Preliminary structural testing has shown paraffin wax to be a brittle, low strength material, and at risk of failure under launch loading conditions. Structural enhancing additives have been identified, but their effect on motor performance has not always been considered, nor has any standard method of testing been identified between research institutes. A review of existing regression rate measurement techniques on paraffin wax based fuels and the results obtained with various additives are collated and discussed in this paper. The review includes 2D slab motors that enable visualisation of liquefying fuel droplet entrainment and the effect of an increased viscosity on the droplet entrainment mechanism, which can occur with the addition of structural enhancing polymers. An increased viscosity has been shown to reduce the regression rate of liquefying fuels. Viscosity increasing additives that have been tested include EVA and LDPE. Both these additives increase the structural properties of paraffin wax, where the elongation and UTS are improved. Other additives, such as metal hydrides, aluminium and boron generally offer improvements on the regression rate. However, very little consideration has been given to the structural effects these additives have on the wax grain. A 40% aluminised grain, for example, offers a slight increase in the UTS but reduces the elongation of paraffin wax. Geometrically accurate lab-scale motors have also been used to determine the regression rate properties of various additives in paraffin wax. A concise review of all available regression rate testing techniques and results on paraffin wax based hybrid propellants, as well as existing structural testing data, is presented in this paper.

  12. 30 CFR 75.151 - Tests for methane; qualified person; additional requirement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tests for methane; qualified person; additional... Certified Persons § 75.151 Tests for methane; qualified person; additional requirement. Notwithstanding the... methane unless he demonstrates to the satisfaction of an authorized representative of the Secretary that...

  13. 30 CFR 75.151 - Tests for methane; qualified person; additional requirement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Tests for methane; qualified person; additional... Certified Persons § 75.151 Tests for methane; qualified person; additional requirement. Notwithstanding the... methane unless he demonstrates to the satisfaction of an authorized representative of the Secretary that...

  14. Tough, high performance, addition-type thermoplastic polymers

    NASA Technical Reports Server (NTRS)

    Pater, Ruth H. (Inventor)

    1992-01-01

    A tough, high performance polyimide is provided by reacting a triple bond conjugated with an aromatic ring in a bisethynyl compound with the active double bond in a compound containing a double bond activated toward the formation of a Diels-Adler type adduct, especially a bismaleimide, a biscitraconimide, or a benzoquinone, or mixtures thereof. Addition curing of this product produces a high linear polymeric structure and heat treating the highly linear polymeric structure produces a thermally stable aromatic addition-type thermoplastic polyimide, which finds utility in the preparation of molding compounds, adhesive compositions, and polymer matrix composites.

  15. Enhancing the fathead minnow fish embryo toxicity test: Optimizing embryo production and assessing the utility of additional test endpoints.

    PubMed

    Roush, Kyle S; Krzykwa, Julie C; Malmquist, Jacob A; Stephens, Dane A; Sellin Jeffries, Marlo K

    2018-05-30

    The fathead minnow fish embryo toxicity (FET) test has been identified as a potential alternative to toxicity test methods that utilize older fish. However, several challenges have been identified with the fathead minnow FET test, including: 1) difficulties in obtaining appropriately-staged embryos for FET test initiation, 2) a paucity of data comparing fathead minnow FET test performance to the fathead minnow larval growth and survival (LGS) test and 3) a lack of sublethal endpoints that could be used to estimate chronic toxicity and/or predict adverse effects. These challenges were addressed through three study objectives. The first objective was to optimize embryo production by assessing the effect of breeding group composition (number of males and females) on egg production. Results showed that groups containing one male and four females produced the largest clutches, enhancing the likelihood of procuring sufficient numbers of embryos for FET test initiation. The second study objective was to compare the performance of the FET test to that of the fathead minnow LGS test using three reference toxicants. The FET and LGS tests were similar in their ability to predict the acute toxicity of sodium chloride and ethanol, but the FET test was found to be more sensitive than the LGS test for sodium dodecyl sulfate. The last objective of the study was to evaluate the utility and practicality of several sublethal metrics (i.e., growth, developmental abnormalities and growth- and stress-related gene expression) as FET test endpoints. Developmental abnormalities, including pericardial edema and hatch success, were found to offer the most promise as additional FET test endpoints, given their responsiveness, potential for predicting adverse effects, ease of assessment and low cost of measurement. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. 20 CFR 666.110 - May a Governor require additional indicators of performance?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 3 2011-04-01 2011-04-01 false May a Governor require additional indicators... of Performance § 666.110 May a Governor require additional indicators of performance? Yes, Governors may develop additional indicators of performance for adults, youth and dislocated worker activities...

  17. 20 CFR 666.110 - May a Governor require additional indicators of performance?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false May a Governor require additional indicators... of Performance § 666.110 May a Governor require additional indicators of performance? Yes, Governors may develop additional indicators of performance for adults, youth and dislocated worker activities...

  18. 40 CFR 63.1161 - Performance testing and test methods.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Facilities and Hydrochloric Acid Regeneration Plants § 63.1161 Performance testing and test methods. (a...) Establishment of hydrochloric acid regeneration plant operating parameters. (1) During the performance test for hydrochloric acid regeneration plants, the owner or operator shall establish site-specific operating parameter...

  19. 40 CFR 63.1161 - Performance testing and test methods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Facilities and Hydrochloric Acid Regeneration Plants § 63.1161 Performance testing and test methods. (a...) Establishment of hydrochloric acid regeneration plant operating parameters. (1) During the performance test for hydrochloric acid regeneration plants, the owner or operator shall establish site-specific operating parameter...

  20. Safety Performance of Airborne Separation: Preliminary Baseline Testing

    NASA Technical Reports Server (NTRS)

    Consiglio, Maria C.; Hoadley, Sherwood T.; Wing, David J.; Baxley, Brian T.

    2007-01-01

    The Safety Performance of Airborne Separation (SPAS) study is a suite of Monte Carlo simulation experiments designed to analyze and quantify safety behavior of airborne separation. This paper presents results of preliminary baseline testing. The preliminary baseline scenario is designed to be very challenging, consisting of randomized routes in generic high-density airspace in which all aircraft are constrained to the same flight level. Sustained traffic density is varied from approximately 3 to 15 aircraft per 10,000 square miles, approximating up to about 5 times today s traffic density in a typical sector. Research at high traffic densities and at multiple flight levels are planned within the next two years. Basic safety metrics for aircraft separation are collected and analyzed. During the progression of experiments, various errors, uncertainties, delays, and other variables potentially impacting system safety will be incrementally introduced to analyze the effect on safety of the individual factors as well as their interaction and collective effect. In this paper we report the results of the first experiment that addresses the preliminary baseline condition tested over a range of traffic densities. Early results at five times the typical traffic density in today s NAS indicate that, under the assumptions of this study, airborne separation can be safely performed. In addition, we report on initial observations from an exploration of four additional factors tested at a single traffic density: broadcast surveillance signal interference, extent of intent sharing, pilot delay, and wind prediction error.

  1. Test Methodologies for Hydrogen Sensor Performance Assessment: Chamber vs. Flow Through Test Apparatus: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buttner, William J; Hartmann, Kevin S; Schmidt, Kara

    Certification of hydrogen sensors to standards often prescribes using large-volume test chambers [1, 2]. However, feedback from stakeholders such as sensor manufacturers and end-users indicate that chamber test methods are often viewed as too slow and expensive for routine assessment. Flow through test methods potentially are an efficient, cost-effective alternative for sensor performance assessment. A large number of sensors can be simultaneously tested, in series or in parallel, with an appropriate flow through test fixture. The recent development of sensors with response times of less than 1s mandates improvements in equipment and methodology to properly capture the performance of thismore » new generation of fast sensors; flow methods are a viable approach for accurate response and recovery time determinations, but there are potential drawbacks. According to ISO 26142 [1], flow through test methods may not properly simulate ambient applications. In chamber test methods, gas transport to the sensor can be dominated by diffusion which is viewed by some users as mimicking deployment in rooms and other confined spaces. Alternatively, in flow through methods, forced flow transports the gas to the sensing element. The advective flow dynamics may induce changes in the sensor behaviour relative to the quasi-quiescent condition that may prevail in chamber test methods. One goal of the current activity in the JRC and NREL sensor laboratories [3, 4] is to develop a validated flow through apparatus and methods for hydrogen sensor performance testing. In addition to minimizing the impact on sensor behaviour induced by differences in flow dynamics, challenges associated with flow through methods include the ability to control environmental parameters (humidity, pressure and temperature) during the test and changes in the test gas composition induced by chemical reactions with upstream sensors. Guidelines on flow through test apparatus design and protocols for the

  2. Thermal Performance Testing of EMU and CSAFE Liquid Cooling Gannents

    NASA Technical Reports Server (NTRS)

    Rhodes, Richard; Bue, Grant; Meginnis, Ian; Hakam, Mary; Radford, Tamara

    2013-01-01

    Future exploration missions require the development of a new liquid cooling garment (LCG) to support the next generation extravehicular activity (EVA) suit system. The new LCG must offer greater system reliability, optimal thermal performance as required by mission directive, and meet other design requirements including improved tactile comfort. To advance the development of a future LCG, a thermal performance test was conducted to evaluate: (1) the comparable thermal performance of the EMU LCG and the CSAFE developed engineering evaluation unit (EEU) LCG, (2) the effect of the thermal comfort undergarment (TCU) on the EMU LCG tactile and thermal comfort, and (3) the performance of a torso or upper body only LCG shirt to evaluate a proposed auxiliary loop. To evaluate the thermal performance of each configuration, a metabolic test was conducted using the Demonstrator Spacesuit to create a relevant test environment. Three (3) male test subjects of similar height and weight walked on a treadmill at various speeds to produce three different metabolic loads - resting (300-600 BTU/hr), walking at a slow pace (1200 BTU/hr), and walking at a brisk pace (2200 BTU/hr). Each subject participated in five tests - two wearing the CSAFE full LCG, one wearing the EMU LCG without TCUs, one wearing the EMU LCG with TCUs, and one with the CSAFE shirt-only. During the test, performance data for the breathing air and cooling water systems and subject specific data was collected to define the thermal performance of the configurations. The test results show that the CSAFE EEU LCG and EMU LCG with TCU had comparable performance. The testing also showed that an auxiliary loop LCG, sized similarly to the shirt-only configuration, should provide adequate cooling for contingency scenarios. Finally, the testing showed that the TCU did not significantly hinder LCG heat transfer, and may prove to be acceptable for future suit use with additional analysis and testing.

  3. Performance Testing of a Trace Contaminant Control Subassembly for the International Space Station

    NASA Technical Reports Server (NTRS)

    Perry, J. L.; Curtis, R. E.; Alexandre, K. L.; Ruggiero, L. L.; Shtessel, N.

    1998-01-01

    As part of the International Space Station (ISS) Trace Contaminant Control Subassembly (TCCS) development, a performance test has been conducted to provide reference data for flight verification analyses. This test, which used the U.S. Habitation Module (U.S. Hab) TCCS as the test article, was designed to add to the existing database on TCCS performance. Included in this database are results obtained during ISS development testing; testing of functionally similar TCCS prototype units; and bench scale testing of activated charcoal, oxidation catalyst, and granular lithium hydroxide (LiOH). The present database has served as the basis for the development and validation of a computerized TCCS process simulation model. This model serves as the primary means for verifying the ISS TCCS performance. In order to mitigate risk associated with this verification approach, the U.S. Hab TCCS performance test provides an additional set of data which serve to anchor both the process model and previously-obtained development test data to flight hardware performance. The following discussion provides relevant background followed by a summary of the test hardware, objectives, requirements, and facilities. Facility and test article performance during the test is summarized, test results are presented, and the TCCS's performance relative to past test experience is discussed. Performance predictions made with the TCCS process model are compared with the U.S. Hab TCCS test results to demonstrate its validation.

  4. 40 CFR 63.1546 - Performance testing.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 13 2012-07-01 2012-07-01 false Performance testing. 63.1546 Section... Emission Standards for Hazardous Air Pollutants for Primary Lead Smelting § 63.1546 Performance testing. (a... performance test shall consist of at least three runs. For each test run with Method 12 or Method 29, the...

  5. Model-Scale Aerodynamic Performance Testing of Proposed Modifications to the NASA Langley Low Speed Aeroacoustic Wind Tunnel

    NASA Technical Reports Server (NTRS)

    Booth, Earl R., Jr.; Coston, Calvin W., Jr.

    2005-01-01

    Tests were performed on a 1/20th-scale model of the Low Speed Aeroacoustic Wind Tunnel to determine the performance effects of insertion of acoustic baffles in the tunnel inlet, replacement of the existing collector with a new collector design in the open jet test section, and addition of flow splitters to the acoustic baffle section downstream of the test section. As expected, the inlet baffles caused a reduction in facility performance. About half of the performance loss was recovered by addition the flow splitters to the downstream baffles. All collectors tested reduced facility performance. However, test chamber recirculation flow was reduced by the new collector designs and shielding of some of the microphones was reduced owing to the smaller size of the new collector. Overall performance loss in the facility is expected to be a 5 percent top flow speed reduction, but the facility will meet OSHA limits for external noise levels and recirculation in the test section will be reduced.

  6. Mariner Mars 1971 battery design, test, and flight performance

    NASA Technical Reports Server (NTRS)

    Bogner, R. S.

    1973-01-01

    The design, integration, fabrication, test results, and flight performance of the battery system for the Mariner Mars spacecraft launched in May 1971 are presented. The battery consists of 26 20-Ah hermetically sealed nickel-cadmium cells housed in a machined magnesium chassis. The battery package weighs 29.5 kg and is unique in that the chassis also serves as part of the spacecraft structure. Active thermal control is accomplished by louvers mounted to the battery baseplate. Battery charge is accomplished by C/10 and C/30 constant current chargers. The switch from the high-rate to low-rate charge is automatic, based on terminal voltage. Additional control is possible by ground command or onboard computer. The performance data from the flight battery is compared to the data from various battery tests in the laboratory. Flight battery data was predictable based on ground test data.

  7. 40 CFR 63.1546 - Performance testing.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 13 2013-07-01 2012-07-01 true Performance testing. 63.1546 Section 63... Emission Standards for Hazardous Air Pollutants for Primary Lead Smelting § 63.1546 Performance testing. (a... performance test shall consist of at least three runs. For each test run with Method 12 or Method 29, the...

  8. Polymeric additive performance in closed whitewater systems

    Treesearch

    T. H. Wegner

    1984-01-01

    “With more stringent requirements on discharge water quality and with escalating water treatment costs, water recycling within the paper mill is of growing importance. A serious problem resulting from more white-water recycling is reduced drainage and fiber or fines retention because of diminished polymeric additive performance. To provide better insight for overcoming...

  9. Clock face drawing test performance in children with ADHD.

    PubMed

    Ghanizadeh, Ahmad; Safavi, Salar; Berk, Michael

    2013-01-01

    The utility and discriminatory pattern of the clock face drawing test in ADHD is unclear. This study therefore compared Clock Face Drawing test performance in children with ADHD and controls. 95 school children with ADHD and 191 other children were matched for gender ratio and age. ADHD symptoms severities were assessed using DSM-IV ADHD checklist and their intellectual functioning was assessed. The participants completed three clock-drawing tasks, and the following four functions were assessed: Contour score, Numbers score, Hands setting score, and Center score. All the subscales scores of the three clock drawing tests of the ADHD group were lower than that of the control group. In ADHD children, inattention and hyperactivity/ impulsivity scores were not related to free drawn clock test scores. When pre-drawn contour test was performed, inattentiveness score was statistically associated with Number score while none of the other variables of age, gender, intellectual functioning, and hand use preference were associated with that kind of score. In pre-drawn clock, no association of ADHD symptoms with any CDT subscales found significant. In addition, more errors are observed with free drawn clock and Pre-drawn contour than pre-drawn clock. Putting Numbers and Hands setting are more sensitive measures to screen ADHD than Contour and Center drawing. Test performance, except Hands setting, may have already reached a developmental plateau. It is probable that Hand setting deficit in children with ADHD may not decrease from age 8 to 14 years. Performance of children with ADHD is associated with complexity of CDT.

  10. Note-Taking Quality and Performance on an L2 Academic Listening Test

    ERIC Educational Resources Information Center

    Song, Min-Young

    2012-01-01

    This study investigated the relationships among the quality of L2 test takers' notes evaluated in terms of different levels of information and test takers' performance on open-ended listening tasks tapping into different comprehension subskills. In addition, this study examined the invariance of the structural relationships among the variables…

  11. Formulation and Testing of Paraffin-Based Solid Fuels Containing Energetic Additives for Hybrid Rockets

    NASA Technical Reports Server (NTRS)

    Larson, Daniel B.; Boyer, Eric; Wachs,Trevor; Kuo, Kenneth K.; Story, George

    2012-01-01

    Many approaches have been considered in an effort to improve the regression rate of solid fuels for hybrid rocket applications. One promising method is to use a fuel with a fast burning rate such as paraffin wax; however, additional performance increases to the fuel regression rate are necessary to make the fuel a viable candidate to replace current launch propulsion systems. The addition of energetic and/or nano-sized particles is one way to increase mass-burning rates of the solid fuels and increase the overall performance of the hybrid rocket motor.1,2 Several paraffin-based fuel grains with various energetic additives (e.g., lithium aluminum hydride (LiAlH4) have been cast in an attempt to improve regression rates. There are two major advantages to introducing LiAlH4 additive into the solid fuel matrix: 1) the increased characteristic velocity, 2) decreased dependency of Isp on oxidizer-to-fuel ratio. The testing and characterization of these solid-fuel grains have shown that continued work is necessary to eliminate unburned/unreacted fuel in downstream sections of the test apparatus.3 Changes to the fuel matrix include higher melting point wax and smaller energetic additive particles. The reduction in particle size through various methods can result in more homogeneous grain structure. The higher melting point wax can serve to reduce the melt-layer thickness, allowing the LiAlH4 particles to react closer to the burning surface, thus increasing the heat feedback rate and fuel regression rate. In addition to the formulation of LiAlH4 and paraffin wax solid-fuel grains, liquid additives of triethylaluminum and diisobutylaluminum hydride will be included in this study. Another promising fuel formulation consideration is to incorporate a small percentage of RDX as an additive to paraffin. A novel casting technique will be used by dissolving RDX in a solvent to crystallize the energetic additive. After dissolving the RDX in a solvent chosen for its compatibility

  12. 40 CFR 610.63 - Performance tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Performance tests. 610.63 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.63 Performance tests... 0 to 60 mph acceleration tests (at normal ambient temperatures) on the baseline vehicle...

  13. 40 CFR 610.63 - Performance tests.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Performance tests. 610.63 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.63 Performance tests... 0 to 60 mph acceleration tests (at normal ambient temperatures) on the baseline vehicle...

  14. 40 CFR 610.63 - Performance tests.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Performance tests. 610.63 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.63 Performance tests... 0 to 60 mph acceleration tests (at normal ambient temperatures) on the baseline vehicle...

  15. 40 CFR 610.63 - Performance tests.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Performance tests. 610.63 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.63 Performance tests... 0 to 60 mph acceleration tests (at normal ambient temperatures) on the baseline vehicle...

  16. 47 CFR 76.601 - Performance tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Performance tests. 76.601 Section 76.601... CABLE TELEVISION SERVICE Technical Standards § 76.601 Performance tests. (a) The operator of each cable... cable television system shall conduct complete performance tests of that system at least twice each...

  17. 47 CFR 76.601 - Performance tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Performance tests. 76.601 Section 76.601... CABLE TELEVISION SERVICE Technical Standards § 76.601 Performance tests. (a) The operator of each cable... cable television system shall conduct complete performance tests of that system at least twice each...

  18. 47 CFR 76.601 - Performance tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Performance tests. 76.601 Section 76.601... CABLE TELEVISION SERVICE Technical Standards § 76.601 Performance tests. (a) The operator of each cable... cable television system shall conduct complete performance tests of that system at least twice each...

  19. Physiological and performance changes from the addition of a sprint interval program to wrestling training.

    PubMed

    Farzad, Babak; Gharakhanlou, Reza; Agha-Alinejad, Hamid; Curby, David G; Bayati, Mahdi; Bahraminejad, Morteza; Mäestu, Jarek

    2011-09-01

    Increasing the level of physical fitness for competition is the primary goal of any conditioning program for wrestlers. Wrestlers often need to peak for competitions several times over an annual training cycle. Additionally, the scheduling of these competitions does not always match an ideal periodization plan and may require a modified training program to achieve a high level of competitive fitness in a short-time frame. The purpose of this study was to examine the effects of 4 weeks of sprint-interval training (SIT) program, on selected aerobic and anaerobic performance indices, and hormonal and hematological adaptations, when added to the traditional Iranian training of wrestlers in their preseason phase. Fifteen trained wrestlers were assigned to either an experimental (EXP) or a control (CON) group. Both groups followed a traditional preparation phase consisting of learning and drilling technique, live wrestling and weight training for 4 weeks. In addition, the EXP group performed a running-based SIT protocol. The SIT consisted of 6 35-m sprints at maximum effort with a 10-second recovery between each sprint. The SIT protocol was performed in 2 sessions per week, for the 4 weeks of the study. Before and after the 4-week training program, pre and posttesting was performed on each subject on the following: a graded exercise test (GXT) to determine VO(2)max, the velocity associated with V(2)max (νVO(2)max), maximal ventilation, and peak oxygen pulse; a time to exhaustion test (T(max)) at their νVO(2)max; and 4 successive Wingate tests with a 4-minute recovery between each trial for the determination of peak and mean power output (PPO, MPO). Resting blood samples were also collected at the beginning of each pre and posttesting period, before and after the 4-week training program. The EXP group showed significant improvements in VO(2)max (+5.4%), peak oxygen pulse (+7.7%) and T(max) (+32.2%) compared with pretesting. The EXP group produced significant increases

  20. Enhanced performance of ultracapacitors using redox additive-based electrolytes

    NASA Astrophysics Data System (ADS)

    Jain, Dharmendra; Kanungo, Jitendra; Tripathi, S. K.

    2018-05-01

    Different concentrations of potassium iodide (KI) as redox additive had been added to 1 M sulfuric acid (H2SO4) electrolyte with an aim of enhancing the capacitance and energy density of ultracapacitors via redox reactions at the interfaces of electrode-electrolyte. Ultracapacitors were fabricated using chemically treated activated carbon as electrode with H2SO4 and H2SO4-KI as an electrolyte. The electrochemical performances of fabricated supercapacitors were investigated by impedance spectroscopy, cyclic voltammetry and charge-discharge techniques. The maximum capacitance ` C' was observed with redox additives-based electrolyte system comprising 1 M H2SO4-0.3 M KI (1072 F g- 1), which is very much higher than conventional 1 M H2SO4 (61.3 F g- 1) aqueous electrolyte-based ultracapacitors. It corresponds to an energy density of 20.49 Wh kg- 1 at 2.1 A g- 1 for redox additive-based electrolyte, which is six times higher as compared to that of pristine electrolyte (1 M H2SO4) having energy density of only 3.36 Wh kg- 1. The temperature dependence behavior of fabricated cell was also analyzed, which shows increasing pattern in its capacitance values in a temperature range of 5-70 °C. Under cyclic stability test, redox electrolyte-based system shows almost 100% capacitance retention up to 5000 cycles and even more. For comparison, ultracapacitors based on polymer gel electrolyte polyvinyl alcohol (PVA) (10 wt%)—{H2SO4 (1 M)-KI (0.3 M)} (90 wt%) have been fabricated and characterized with the same electrode materials.

  1. Feasibility and Testing of Additive Manufactured Components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dehoff, Ryan R.; Hummelt, Ed; Solovyeva, Lyudmila

    2016-09-01

    This project focused on demonstrating the ability to fabricate two parts with different geometry: an arc flash interrupter and a hydraulic manifold. Eaton Corporation provided ORNL solid models, information related to tolerances and sensitive parameters of the parts and provided testing and evaluation. ORNL successfully manufactured both components, provided cost models of the manufacturing (materials, labor, time and post processing) and delivered test components for Eaton evaluation. The arc flash suppressor was fabricated using the Renishaw laser powder bed technology in CoCrMo while the manifold was produced from Ti-6Al-4V using the Arcam electron beam melting technology. These manufacturing techniques weremore » selected based on the design and geometrical tolerances required. A full-scale manifold was produced on the Arcam A2 system (nearly 12 inches tall). A portion of the manifold was also produced in the Arcam Q10 system. Although a full scale manifold could not be produced in the system, a full scale manifold is expected to have similar material properties, geometric accuracy, and surface finish as could be fabricated on an Arcam Q20 system that is capable of producing four full scale manifolds in a production environment. In addition to the manifold, mechanical test specimens, geometric tolerance artifacts, and microstructure samples were produced alongside the manifold. The development and demonstration of these two key components helped Eaton understand the impact additive manufacturing can have on many of their existing products. By working within the MDF and leveraging ORNL’s manufacturing and characterization capabilities, the work will ensure the rapid insertion and commercialization of this technology.« less

  2. Memory functions in chronic pain: examining contributions of attention and age to test performance.

    PubMed

    Oosterman, Joukje M; Derksen, Laura C; van Wijck, Albert J M; Veldhuijzen, Dieuwke S; Kessels, Roy P C

    2011-01-01

    Previous studies have revealed that memory performance is diminished in chronic pain patients. Few studies, however, have assessed multiple components of memory in a single sample. It is currently also unknown whether attentional problems, which are commonly observed in chronic pain, mediate the decline in memory. Finally, previous studies have focused on middle-aged adults, and a possible detrimental effect of aging on memory performance in chronic pain patients has been commonly disregarded. This study, therefore, aimed at describing the pattern of semantic, working, and visual and verbal episodic memory performance in participants with chronic pain, while testing for possible contributions of attention and age to task performance. Thirty-four participants with chronic pain and 32 pain-free participants completed tests of episodic, semantic, and working memory to assess memory performance and a test of attention. Participants with chronic pain performed worse on tests of working memory and verbal episodic memory. A decline in attention explained some, but not all, group differences in memory performance. Finally, no additional effect of age on the diminished task performance in participants with chronic pain was observed. Taken together, the results indicate that chronic pain significantly affects memory performance. Part of this effect may be caused by underlying attentional dysfunction, although this could not fully explain the observed memory decline. An increase in age in combination with the presence of chronic pain did not additionally affect memory performance.

  3. Situational judgment test as an additional tool in a medical admission test: an observational investigation.

    PubMed

    Luschin-Ebengreuth, Marion; Dimai, Hans P; Ithaler, Daniel; Neges, Heide M; Reibnegger, Gilbert

    2015-03-14

    In the framework of medical university admission procedures the assessment of non-cognitive abilities is increasingly demanded. As tool for assessing personal qualities or the ability to handle theoretical social constructs in complex situations, the Situational Judgment Test (SJT), among other measurement instruments, is discussed in the literature. This study focuses on the development and the results of the SJT as part of the admission test for the study of human medicine and dentistry at one medical university in Austria. Observational investigation focusing on the results of the SJT. 4741 applicants were included in the study. To yield comparable results for the different test parts, "relative scores" for each test part were calculated. Performance differences between women and men in the various test parts are analyzed using effect sizes based on comparison of mean values (Cohen's d). The associations between the relative scores achieved in the various test parts were assessed by computing pairwise linear correlation coefficients between all test parts and visualized by bivariate scatterplots. Among successful candidates, men consistently outperform women. Men perform better in physics and mathematics. Women perform better in the SJT part. The least discriminatory test part was the SJT. A strong correlation between biology and chemistry and moderate correlations between the other test parts except SJT is obvious. The relative scores are not symmetrically distributed. The cognitive loading of the performed SJTs points to the low correlation between the SJTs and cognitive abilities. Adding the SJT part into the admission test, in order to cover more than only knowledge and understanding of natural sciences among the applicants has been quite successful.

  4. Effect of kaolin addition on the performance of controlled low-strength material using industrial waste incineration bottom ash.

    PubMed

    Naganathan, Sivakumar; Razak, Hashim Abdul; Hamid, Siti Nadzriah Abdul

    2010-09-01

    Incineration of industrial waste produces large quantities of bottom ash which are normally sent to secured landfill, but is not a sustainable solution. Use of bottom ash in engineering applications will contribute to sustainability and generate revenue. One way of using the industrial waste incineration bottom ash is in controlled low-strength material (CLSM). Use of bottom ash in CLSM has problems related to bleeding and excessive strength development and so an additive has to be used to control bleeding and strength development. The main objective of this research is to study the effect of kaolin addition on the performance of CLSM made using industrial waste incineration bottom ash. CLSM mixes were made with bottom ash, cement, and refined kaolin. Various tests were performed on the CLSM in fresh and hardened states including compressive strength, water absorption, California bearing ratio (CBR) and the tests for concentration of leachable substances on the bleed and leachate. The compressive strength of CLSM tested ranged from 0.11 to 9.86 MPa. CBR values ranged from 6 to 46, and water absorption values from 12 to 36%. It was shown that the addition of kaolin delayed the initial setting time of CLSM mixtures, reduced bleeding, lowered the compressive strength, and increased the values of water absorption, sorption, and initial surface absorption. The CLSM tested did not have corrosivity. It was shown that the hardened CLSM was non hazardous, and the addition of kaolin increased the concentration of heavy metals and salts in the bleed and leachate.

  5. Computer versus paper--does it make any difference in test performance?

    PubMed

    Karay, Yassin; Schauber, Stefan K; Stosch, Christoph; Schüttpelz-Brauns, Katrin

    2015-01-01

    CONSTRUCT: In this study, we examine the differences in test performance between the paper-based and the computer-based version of the Berlin formative Progress Test. In this context it is the first study that allows controlling for students' prior performance. Computer-based tests make possible a more efficient examination procedure for test administration and review. Although university staff will benefit largely from computer-based tests, the question arises if computer-based tests influence students' test performance. A total of 266 German students from the 9th and 10th semester of medicine (comparable with the 4th-year North American medical school schedule) participated in the study (paper = 132, computer = 134). The allocation of the test format was conducted as a randomized matched-pair design in which students were first sorted according to their prior test results. The organizational procedure, the examination conditions, the room, and seating arrangements, as well as the order of questions and answers, were identical in both groups. The sociodemographic variables and pretest scores of both groups were comparable. The test results from the paper and computer versions did not differ. The groups remained within the allotted time, but students using the computer version (particularly the high performers) needed significantly less time to complete the test. In addition, we found significant differences in guessing behavior. Low performers using the computer version guess significantly more than low-performing students in the paper-pencil version. Participants in computer-based tests are not at a disadvantage in terms of their test results. The computer-based test required less processing time. The reason for the longer processing time when using the paper-pencil version might be due to the time needed to write the answer down, controlling for transferring the answer correctly. It is still not known why students using the computer version (particularly low-performing

  6. Uniform peanut performance test 2017

    USDA-ARS?s Scientific Manuscript database

    The Uniform Peanut Performance Tests (UPPT) are designed to evaluate the commercial potential of advanced breeding peanut lines not formally released. The tests are performed in ten locations across the peanut production belt. In this study, 2 controls and 14 entries were evaluated at 8 locations....

  7. 40 CFR 63.7 - Performance testing requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Performance testing requirements. (a) Applicability and performance test dates. (1) The applicability of this... or operator of the affected source must perform such tests within 180 days of the compliance date for... standard initially, the owner or operator shall conduct a second performance test within 3 years and 180...

  8. 40 CFR 63.344 - Performance test requirements and test methods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... blanket type fume suppressants are used to control chromium emissions from a hard chromium electroplating... National Emission Standards for Chromium Emissions From Hard and Decorative Chromium Electroplating and Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test...

  9. 40 CFR 63.344 - Performance test requirements and test methods.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... blanket type fume suppressants are used to control chromium emissions from a hard chromium electroplating... National Emission Standards for Chromium Emissions From Hard and Decorative Chromium Electroplating and Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test...

  10. 40 CFR 63.344 - Performance test requirements and test methods.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... blanket type fume suppressants are used to control chromium emissions from a hard chromium electroplating... National Emission Standards for Chromium Emissions From Hard and Decorative Chromium Electroplating and Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test...

  11. Is Patch Testing with Food Additives Useful in Children with Atopic Eczema?

    PubMed

    Catli, Gonul; Bostanci, Ilknur; Ozmen, Serap; Dibek Misirlioglu, Emine; Duman, Handan; Ertan, Ulker

    2015-01-01

    Atopy patch testing is a useful way to determine delayed-type hypersensitivity reactions to foods and aeroallergens. Although food additives have been accused of worsening atopic eczema symptoms, according to recent studies the role of food additives in atopic eczema remains unclear. The purpose of our study was to investigate food additive hypersensitivity in a group of children with atopic eczema by using standardized atopy patch testing and to determine the role of food additive hypersensitivity in atopic eczema. Thirty-four children with atopic eczema and 33 healthy children were enrolled in the study. Children who consumed foods containing additives and did not use either antihistamines or local or systemic corticosteroids for at least 7 days prior to admission were enrolled in the study. All children were subjected to atopy patch testing and after 48 and 72 hours their skin reactions were evaluated by using the guidelines. Positive atopy patch test results were significantly higher in the atopic eczema group. Forty-one percent of the atopic eczema group (n = 14) and 15.2% (n = 5) of the control group had positive atopy patch test results with food additives (p = 0.036) (estimated relative risk 1.68, case odds 0.7, control odds 0.17). Carmine hypersensitivity and the consumption of foods containing carmine, such as gumdrops, salami, and sausage, were significantly higher in the children with atopic eczema. This is the first study investigating hypersensitivity to food additives in children with atopic eczema. Our results indicate that carmine may play a role in atopic eczema. © 2015 Wiley Periodicals, Inc.

  12. Mechanical Performance of Cold-Sprayed A357 Aluminum Alloy Coatings for Repair and Additive Manufacturing

    NASA Astrophysics Data System (ADS)

    Petráčková, K.; Kondás, J.; Guagliano, M.

    2017-12-01

    Cold-sprayed coatings made of A357 aluminum alloy, a casting alloy widely used in aerospace, underwent set of standard tests as well as newly developed fatigue test to gain an information about potential of cold spray for repair and additive manufacturing of loaded parts. With optimal spray parameters, coating deposition on substrate with smooth surface resulted in relatively good bonding, which can be further improved by application of grit blasting on substrate's surface. However, no enhancement of adhesion was obtained for shot-peened surface. Process temperature, which was set either to 450 or 550 °C, was shown to have an effect on adhesion and cohesion strength, but it does not influence residual stress in the coating. To assess cold spray perspectives for additive manufacturing, flat tensile specimens were machined from coating and tested in as-sprayed and heat-treated (solution treatment and aging) condition. Tensile properties of the coating after the treatment correspond to properties of the cast A357-T61 aluminum alloy. Finally, fatigue specimen was proposed to test overall performance of the coating and coating's fatigue limit is compared to the results obtained on cast A357-T61 aluminum alloy.

  13. Evaluation of Foaming Performance of Bitumen Modified with the Addition of Surface Active Agent

    NASA Astrophysics Data System (ADS)

    Chomicz-Kowalska, Anna; Mrugała, Justyna; Maciejewski, Krzysztof

    2017-10-01

    The article presents the analysis of the performance of foamed bitumen modified using surface active agents. Although, bitumen foaming permits production of asphalt concrete and other asphalt mix types without using chemical additives in significantly reduced temperatures, the decrease in processing temperatures still impacts the adhesion performance and bitumen coating of aggregates in final mixes. Therefore, in some cases it may be feasible to incorporate adhesion promoters and surface active agents into warm and half-warm mixes with foamed bitumen to increase their service life and resilience. Because of the various nature of the available surface active agents, varying bitumen compatibility and their possible impact on the rheological properties of bitumen, the introduction of surface active agents may significantly alter the bitumen foaming performance. The tests included basic performance tests of bitumen before and after foaming. The two tested bitumen were designated as 35/50 and 50/70 penetration grade binders, which were modified with a surface active agent widely used for improving mixture workability, compactibility and adhesion in a wide range of asphalt mixes and techniques, specifically Warm Mix Asphalt. Alongside to the reference unmodified bitumen, binders with 0.2%, 0.4% and 0.6% surface active agent concentration were tested. The analysis has shown a positive influence of the modifier on the foaming performance of both of the base bitumen increasing their maximum expansion ratio and bitumen foam halflife. In the investigations, it was found that the improvement was dependent on the bitumen type and modifier content. The improved expansion ratio and foam half-life has a positive impact on the aggregate coating and adhesion, which together with the adhesion promoting action of the modifier will have a combined positive effect on the quality of produced final asphalt mixes.

  14. Addition of right-sided and posterior precordial leads during stress testing.

    PubMed

    Shry, Eric A; Eckart, Robert E; Furgerson, James L; Stajduhar, Karl C; Krasuski, Richard A

    2003-12-01

    Exercise treadmill testing has limited sensitivity for the detection of coronary artery disease, frequently requiring the addition of imaging modalities to enhance the predictive value of the test. Recently, there has been interest in using nonstandard electrocardiographic (ECG) leads during exercise testing. We consecutively enrolled all patients undergoing exercise myocardial imaging with four additional leads recorded (V4R, V7, V8, and V9). The test characteristics of the 12-lead, the 15-lead (12-lead, V7, V8, V9), and the 16-lead (12-lead, V4R, V7, V8, V9) ECGs were compared with stress imaging in all patients. In the subset of patients who underwent angiography within 60 days of stress testing, these lead arrays were compared with the catheterization findings. There were 727 subjects who met entry criteria. The mean age was 58.5 +/- 12.3 years, and 366 (50.3%) were women. Pretest probability for disease was high in 241 (33.1%), intermediate in 347 (47.7%), and low in 139 (19.1%). A total of 166 subjects had an abnormal 12-lead ECG during exercise. The addition of 3 posterior leads to the standard 12-lead ECG resulted in 7 additional subjects having an abnormal electrocardiographic response to exercise. The addition of V4R resulted in only 1 additional patient having an abnormal ECG during exercise. The sensitivity of the ECG for detecting ischemia as determined by stress imaging was 36.6%, 39.2%, and 40.0% (P = NS) for the 12-lead, 15-lead, and 16-lead ECGs, respectively. In those with catheterization data (n = 123), the sensitivity for determining obstructive coronary artery disease was 43.5%, 45.2%, and 45.2% (P = NS) for the 12-lead, 15-lead, and 16-lead ECGs, respectively. The sensitivity of imaging modalities was 77.4% when compared with catheterization. In patients undergoing stress imaging studies, the addition of right-sided and posterior leads did not significantly increase the sensitivity of the ECG for the detection of myocardial ischemia

  15. Multilevel microvibration test for performance predictions of a space optical load platform

    NASA Astrophysics Data System (ADS)

    Li, Shiqi; Zhang, Heng; Liu, Shiping; Wang, Yue

    2018-05-01

    This paper presents a framework for the multilevel microvibration analysis and test of a space optical load platform. The test framework is conducted on three levels, including instrument, subsystem, and system level. Disturbance source experimental investigations are performed to evaluate the vibration amplitude and study vibration mechanism. Transfer characteristics of space camera are validated by a subsystem test, which allows the calculation of transfer functions from various disturbance sources to optical performance outputs. In order to identify the influence of the source on the spacecraft performance, a system level microvibration measurement test has been performed on the ground. From the time domain analysis and spectrum analysis of multilevel microvibration tests, we concluded that the disturbance source has a significant effect on its installation position. After transmitted through mechanical links, the residual vibration reduces to a background noise level. In addition, the angular microvibration of the platform jitter is mainly concentrated in the rotation of y-axes. This work is applied to a real practical application involving the high resolution satellite camera system.

  16. Using Copper Nanoparticle Additive to Improve the Performance of Silicon Anodes in Lithium-Ion Batteries

    NASA Astrophysics Data System (ADS)

    Bachand, Gabrielle

    In the foreseeable future, global energy demand is expected to rapidly increase as a result of the swelling population and higher standards of living. Current energy generation and transportation methods predominantly involve the combustion of non-renewable fossil fuels, and greenhouse gas emissions from these processes have been shown to contribute to global climate change and to be detrimental to human and environmental health. To satisfy future energy needs and to reduce greenhouse gas emissions, the advancement of renewable energy generation and electric vehicles is important. The proliferation of intermittent renewable energy sources (such as solar and wind) and electric vehicles depends upon reliable, high-capacity energy storage to serve the practical needs of society. The present-day lithium-ion battery offers excellent qualities for this purpose; however, improvements in the capacity and cost-effectiveness of these batteries are needed for further growth. As an anode material, silicon has exceptionally high theoretical capacity and is an earth-abundant, low-cost option. However, silicon also suffers from poor conductivity and long-term stability, prompting many studies to investigate the use of additive materials to mitigate these issues. This thesis focuses on the improvement of silicon anode performance by using a nanoparticulate copper additive to increase material conductivity and an inexpensive, industry-compatible anode fabrication process. Three main fabrication processes were explored using differing materials and heat treatment techniques for comparison. Anodes were tested using CR2032 type coin cells. The final anodes with the most-improved characteristics were fabricated using a high-temperature heating step for the anode material, and an additional batch was formed to test the viability of the copper additive functioning as a full substitute for carbon black, which is the traditional choice of conductive additive for electrode materials. Anodes

  17. Influence of Antioxidant Addition in Jatropha Biodiesel on the Performance, Combustion and Emission Characteristics of a DI Diesel Engine

    NASA Astrophysics Data System (ADS)

    Arockiasamy, Prabu; Ramachandran Bhagavathiammal, Anand

    2018-04-01

    An experimental investigation is conducted on a single-cylinder DI diesel engine, to evaluate the performance, combustion and emission characteristics of Jatropha biodiesel with the addition of antioxidants namely, Succinimide (C4H5NO2), N,N-Dimethyl p-phenylenediamine dihydrochloride (C8H14Cl2N2) and N-Phenyl- p-phenylenediamine (C6H5NHC6H4NH2) at 500, 1000 and 2000 ppm. The performance, combustion and emission characteristic tests are conducted at a constant speed of 1500 rpm, injection pressure of 215 bar, injection timing of 26° before top dead centre for the nine test fuels and the experimental results are compared with neat diesel and neat biodiesel as base fuels. The experimental results show that the addition of antioxidant in biodiesel suppresses the NO emission by quenching the OH radicals that are produced by the reaction of hydrocarbon radicals with molecular nitrogen. The maximum percentage reduction of NO emission by 5, 6 and 7% are observed for N-Phenyl- p-phenylenediamine, N,N-Dimethyl p-phenylenediamine dihydrochloride and Succinimide blended test fuels at 2000 ppm antioxidant addition with biodiesel.

  18. Sleep quality and duration are associated with performance in maximal incremental test.

    PubMed

    Antunes, B M; Campos, E Z; Parmezzani, S S; Santos, R V; Franchini, E; Lira, F S

    2017-08-01

    Inadequate sleep patterns may be considered a trigger to development of several metabolic diseases. Additionally, sleep deprivation and poor sleep quality can negatively impact performance in exercise training. However, the impact of sleep duration and sleep quality on performance during incremental maximal test performed by healthy men is unclear. Therefore, the purpose of the study was to analyze the association between sleep pattern (duration and quality) and performance during maximal incremental test in healthy male individuals. A total of 28 healthy males volunteered to take part in the study. Sleep quality, sleep duration and physical activity were subjectively assessed by questionnaires. Sleep pattern was classified by sleep duration (>7h or <7h of sleep per night) and sleep quality according to the sum of measured points and/or scores by the Pittsburgh Sleep Quality Index (PSQI). Incremental exercise test was performed at 35 watts for untrained subjects, 70 watts for physically active subjects and 105 watts for well-trained subjects. HR max was correlated with sleep quality (r=0.411, p=0.030) and sleep duration (r=-0.430, p=0.022). Participants reporting good sleep quality presented higher values of W max , VO 2max and lower values of HR max when compared to participants with altered sleep. Regarding sleep duration, only W max was influenced by the amount of sleeping hours per night and this association remained significant even after adjustment by VO 2max . Sleep duration and quality are associated, at least in part, with performance during maximal incremental test among healthy men, with losses in W max and HR max . In addition, our results suggest that the relationship between sleep patterns and performance, mainly in W max , is independent of fitness condition. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Study on thermal effects & sulfurized additives, in lubricating greases

    NASA Astrophysics Data System (ADS)

    Shah, Ami Atul

    Lithium Base grease constitutes about 50% of market. The greases are developed to be able to work in multiple working conditions and have longer working life. Greases with extreme pressure additives and anti-wear additives have been developed as a solution to many of the applications. These developed greases are tested under ASTM D2266 testing conditions to meet the requirements. The actual working conditions, although, differ than the real testing conditions. The loading, speed and temperature conditions can be more harsh, or fluctuating in nature. The cyclic nature of the parameters cannot be directly related to the test performance. For this purpose studies on the performance under spectrum loading, variable speed and fluctuating temperature must be performed. This study includes tests to understand the effect of thermal variation on some of the most commonly used grease additives that perform well under ASTM D2266 testing conditions. The studied additives include most widely used industrial extreme pressure additive MoS2. Performance of ZDDP which is trying to replace MoS2 in its industrial applications has also been studied. The tests cover study of extreme pressure, anti-wear and friction modifier additives to get a general idea on the effects of thermal variation in three areas. Sulphur is the most common extreme pressure additive. Sulphur based MoS 2 is extensively used grease additive. Study to understand the tribological performance of this additive through wear testing and SEM/EDX studies has been done. This performance is also studied for other metallic sulfides like WS2 and sulphur based organic compound. The aim is to study the importance of the type of bond that sulphur shares in its additive's structure on its performance. The MoS2 film formation is found to be on the basis of the FeS formation on the substrate and protection through sacrificial monolayer deposition of the MoS2 sheared structure. The free Mo then tends to oxidise. An attempt to

  20. A test strategy for the assessment of additive attributed toxicity of tobacco products.

    PubMed

    Kienhuis, Anne S; Staal, Yvonne C M; Soeteman-Hernández, Lya G; van de Nobelen, Suzanne; Talhout, Reinskje

    2016-08-01

    The new EU Tobacco Product Directive (TPD) prohibits tobacco products containing additives that are toxic in unburnt form or that increase overall toxicity of the product. This paper proposes a strategy to assess additive attributed toxicity in the context of the TPD. Literature was searched on toxicity testing strategies for regulatory purposes from tobacco industry and governmental institutes. Although mainly traditional in vivo testing strategies have been applied to assess toxicity of unburnt additives and increases in overall toxicity of tobacco products due to additives, in vitro tests combined with toxicogenomics and validated using biomarkers of exposure and disease are most promising in this respect. As such, tests are needed that are sensitive enough to assess additive attributed toxicity above the overall toxicity of tobacco products, which can associate assay outcomes to human risk and exposure. In conclusion, new, sensitive in vitro assays are needed to conclude whether comparable testing allows for assessment of small changes in overall toxicity attributed to additives. A more pragmatic approach for implementation on a short-term is mandated lowering of toxic emission components. Combined with risk assessment, this approach allows assessment of effectiveness of harm reduction strategies, including banning or reducing of additives. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Effects of Total SAT® Test Time on Performance and Fatigue. Research Notes. RN-37

    ERIC Educational Resources Information Center

    Ackerman, Phillip L.; Kanfer, Ruth; Wolman, Stacey D.

    2005-01-01

    The current study was designed to examine performance effects and fatigue effects associated with different total SAT testing times. In addition, the researchers examined personality, motivation, and other determinants of individual differences in examinee fatigue before, during, and after testing.

  2. Judgments of Learning are Influenced by Multiple Cues In Addition to Memory for Past Test Accuracy.

    PubMed

    Hertzog, Christopher; Hines, Jarrod C; Touron, Dayna R

    When people try to learn new information (e.g., in a school setting), they often have multiple opportunities to study the material. One of the most important things to know is whether people adjust their study behavior on the basis of past success so as to increase their overall level of learning (for example, by emphasizing information they have not yet learned). Monitoring their learning is a key part of being able to make those kinds of adjustments. We used a recognition memory task to replicate prior research showing that memory for past test outcomes influences later monitoring, as measured by judgments of learning (JOLs; confidence that the material has been learned), but also to show that subjective confidence in whether the test answer and the amount of time taken to restudy the items also have independent effects on JOLs. We also show that there are individual differences in the effects of test accuracy and test confidence on JOLs, showing that some but not all people use past test experiences to guide monitoring of their new learning. Monitoring learning is therefore a complex process of considering multiple cues, and some people attend to those cues more effectively than others. Improving the quality of monitoring performance and learning could lead to better study behaviors and better learning. An individual's memory of past test performance (MPT) is often cited as the primary cue for judgments of learning (JOLs) following test experience during multi-trial learning tasks (Finn & Metcalfe, 2007; 2008). We used an associative recognition task to evaluate MPT-related phenomena, because performance monitoring, as measured by recognition test confidence judgments (CJs), is fallible and varies in accuracy across persons. The current study used multilevel regression models to show the simultaneous and independent influences of multiple cues on Trial 2 JOLs, in addition to performance accuracy (the typical measure of MPT in cued-recall experiments). These cues

  3. Analytical design and performance studies of nuclear furnace tests of small nuclear light bulb models

    NASA Technical Reports Server (NTRS)

    Latham, T. S.; Rodgers, R. J.

    1972-01-01

    Analytical studies were continued to identify the design and performance characteristics of a small-scale model of a nuclear light bulb unit cell suitable for testing in a nuclear furnace reactor. Emphasis was placed on calculating performance characteristics based on detailed radiant heat transfer analyses, on designing the test assembly for ease of insertion, connection, and withdrawal at the reactor test cell, and on determining instrumentation and test effluent handling requirements. In addition, a review of candidate test reactors for future nuclear light bulb in-reactor tests was conducted.

  4. Relationships between field performance tests in high-level soccer players.

    PubMed

    Ingebrigtsen, Jørgen; Brochmann, Marit; Castagna, Carlo; Bradley, Paul S; Ade, Jack; Krustrup, Peter; Holtermann, Andreas

    2014-04-01

    To reduce athlete testing time, the aim of this study was to investigate the relationship between the Yo-Yo intermittent recovery test levels 1 (IR1) and 2 (IR2) performances, maximal sprinting speed (10, 20, and 35 m), repeated sprint ability (RSA; 7 × 35 m), and submaximal heart rates (HRs) after 2 and 4 minutes of the Yo-Yo IR tests by testing 57 high-level soccer players. All players played regularly in one of 3 highest levels of Norwegian soccer and were tested during 3 sessions on 3 consecutive days. Large correlations were observed between Yo-Yo IR1 and IR2 test performances (r = 0.753, p ≤ 0.05). Small and moderate correlations were found between 20- and 35-m sprinting speed and Yo-Yo IR1 performance (r = -0.289 and -0.321, respectively, p ≤ 0.05), whereas 35-m sprinting speed correlated moderately to Yo-Yo IR2 performance (r = -0.371, p ≤ 0.05). Repeated sprint ability at 10, 20, and 35 m all showed moderate to large correlations to Yo-Yo IR1 performance (r = -0.337 to -0.573, p ≤ 0.05). Repeated sprint ability at 20 m (r = -0.348, p ≤ 0.05) and 35 m (r = -0.552, p ≤ 0.01) correlated moderately and largely to Yo-Yo IR2 performance. In addition, moderate and large correlations were found between submaximal Yo-Yo IR1 HRs after 2 (r = -0.483, p ≤ 0.01) and 4 minutes (r = -0.655, p ≤ 0.01) and Yo-Yo IR1 performance, and 2 minutes Yo-Yo IR2 HR and Yo-Yo IR2 performance (r = -0.530, p ≤ 0.01). Intraclass correlation measures of submaximal HR after 2 and 4 minutes of Yo-Yo IR1 test and after 2 minutes of the Yo-Yo IR2 were 0.92 (coefficient of variation [CV] = 4.1%, n = 33), 0.93 (CV = 3.8%, n = 33), and 0.72 (CV = 2.9%, n = 10). Adjusted ordinary least square (OLS) regressions revealed associations (p ≤ 0.05) between sprint speed at 20 and 35 m and Yo-Yo IR1 test performance, but only between 35 m and IR2 test performance (p ≤ 0.05). Further, OLS showed that RSA at 35 m was related to both levels of the Yo-Yo IR test (p ≤ 0.01), and that

  5. When we test, do we stress? Impact of the testing environment on cortisol secretion and memory performance in older adults.

    PubMed

    Sindi, Shireen; Fiocco, Alexandra J; Juster, Robert-Paul; Pruessner, Jens; Lupien, Sonia J

    2013-08-01

    The majority of studies find that older adults have worse memory performance than young adults. However, contextual features in the testing environment may be perceived as stressful by older adults, increasing their stress hormone levels. Given the evidence that older adults are highly sensitive to the effects of stress hormones (cortisol) on memory performance, it is postulated that a stressful testing environment in older adults can lead to an acute stress response and to memory impairments. The current study compared salivary cortisol levels and memory performance in young and older adults tested in environments manipulated to be stressful (unfavourable condition) or not stressful (favourable condition) for each age group. 28 young adults and 32 older adults were tested in two testing conditions: (1) a condition favouring young adults (constructed to be less stressful for young adults), and (2) a condition favouring older adults (constructed to be less stressful for older adults). The main outcome measure was salivary cortisol levels. Additionally, immediate and delayed memory performances were assessed during each condition. In older adults only, we found significantly high cortisol levels and low memory performance in the condition favouring young adults. In contrast, cortisol levels were lower and memory performance was better when older adults were tested in conditions favouring them. There was no effect of testing condition in young adults. The results demonstrate that older adults' memory performance is highly sensitive to the testing environment. These findings have important implications for both research and clinical settings in which older adults are tested for memory performance. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Stereotype Threat, Test Anxiety, and Mathematics Performance

    ERIC Educational Resources Information Center

    Tempel, Tobias; Neumann, Roland

    2014-01-01

    We investigated the combined effects of stereotype threat and trait test anxiety on mathematics test performance. Stereotype threat and test anxiety interacted with each other in affecting performance. Trait test anxiety predicted performance only in a diagnostic condition that prevented stereotype threat by stereotype denial. A state measure of…

  7. 40 CFR 63.1161 - Performance testing and test methods.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Facilities and Hydrochloric Acid Regeneration Plants § 63.1161 Performance testing and test methods. (a...) or measure the concentration of HCl (and Cl2 for hydrochloric acid regeneration plants) in gases... to the initial test or tests. (c) Establishment of hydrochloric acid regeneration plant operating...

  8. 40 CFR 63.1161 - Performance testing and test methods.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Facilities and Hydrochloric Acid Regeneration Plants § 63.1161 Performance testing and test methods. (a...) or measure the concentration of HCl (and Cl2 for hydrochloric acid regeneration plants) in gases... to the initial test or tests. (c) Establishment of hydrochloric acid regeneration plant operating...

  9. 40 CFR 63.1161 - Performance testing and test methods.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Facilities and Hydrochloric Acid Regeneration Plants § 63.1161 Performance testing and test methods. (a...) or measure the concentration of HCl (and Cl2 for hydrochloric acid regeneration plants) in gases... to the initial test or tests. (c) Establishment of hydrochloric acid regeneration plant operating...

  10. Test set readings predict clinical performance to a limited extent: preliminary findings

    NASA Astrophysics Data System (ADS)

    Soh, BaoLin P.; Lee, Warwick M.; Kench, Peter L.; Reed, Warren M.; McEntee, Mark F.; Brennan, Patrick C.

    2013-03-01

    Aim: To investigate the level of agreement between test sets and actual clinical reading Background: The performance of screen readers in detecting breast cancer is being assessed in some countries by using mammographic test sets. However, previous studies have provided little evidence that performance assessed by test sets strongly correlate to performance in clinical reading. Methods: Five clinicians from BreastScreen New South Wales participated in this study. Each clinician was asked to read 200 de-identified mammographic examinations gathered from their own case history within the BreastScreen NSW Digital Imaging Library. All test sets were designed with specific proportions of true positive, true negative, false positive and false negative examinations from the previous actual clinical reads of each reader. A prior mammogram examination for comparison (when available) was also provided for each case. Results: Preliminary analyses have shown that there is a moderate level of agreement (Kappa 0.42-0.56, p < 0.001) between laboratory test sets and actual clinical reading. In addition, a mean increase of 38% in sensitivity in the laboratory test sets as compared to their actual clinical readings was demonstrated. Specificity is similar between the laboratory test sets and actual clinical reading. Conclusion: This study demonstrated a moderate level of agreement between actual clinical reading and test set reading, which suggests that test sets have a role in reflecting clinical performance.

  11. 30 CFR 250.449 - What additional BOP testing requirements must I meet?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...? You must meet the following additional BOP testing requirements: (a) Use water to test a surface BOP system; (b) Stump test a subsea BOP system before installation. You must use water to conduct this test. You may use drilling fluids to conduct subsequent tests of a subsea BOP system; (c) Alternate tests...

  12. Boosting the Performance of Ionic-Liquid-Based Supercapacitors with Polar Additives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Kun; Wu, Jianzhong

    Recent years have witnessed growing interests in both the fundamentals and applications of electric double layer capacitors (EDLCs), also known as supercapacitors. A number of strategies have been explored to optimize the device performance in terms of both the energy and power densities. Because the properties of electric double layers (EDL) are sensitive to ion distributions in the close vicinity of the electrode surfaces, the supercapacitor performance is sensitive to both the electrode pore structure and the electrolyte composition. In this paper, we study the effects of polar additives on EDLC capacitance using the classical density functional theory within themore » framework of a coarse-grained model for the microscopic structure of the porous electrodes and room-temperature ionic liquids. The theoretical results indicate that a highly polar, low-molecular-weight additive is able to drastically increase the EDLC capacitance at low bulk concentration. Additionally, the additive is able to dampen the oscillatory dependence of the capacitance on the pore size, thereby boosting the performance of amorphous electrode materials. Finally, the theoretical predictions are directly testable with experiments and provide new insights into the additive effects on EDL properties.« less

  13. Validity of the Optometry Admission Test in Predicting Performance in Schools and Colleges of Optometry.

    ERIC Educational Resources Information Center

    Kramer, Gene A.; Johnston, JoElle

    1997-01-01

    A study examined the relationship between Optometry Admission Test scores and pre-optometry or undergraduate grade point average (GPA) with first and second year performance in optometry schools. The test's predictive validity was limited but significant, and comparable to those reported for other admission tests. In addition, the scores…

  14. 40 CFR 1066.430 - Performing emission tests.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Performing emission tests. 1066.430... CONTROLS VEHICLE-TESTING PROCEDURES Vehicle Preparation and Running a Test § 1066.430 Performing emission tests. The overall test consists of prescribed sequences of fueling, parking, and driving at specified...

  15. 40 CFR 1066.430 - Performing emission tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Performing emission tests. 1066.430... CONTROLS VEHICLE-TESTING PROCEDURES Vehicle Preparation and Running a Test § 1066.430 Performing emission tests. The overall test consists of prescribed sequences of fueling, parking, and driving at specified...

  16. Measuring Performance: Teacher-Made Tests.

    ERIC Educational Resources Information Center

    Haladyna, Tom

    Among the new testing developments are the use of objectives or goals in instruction, competency based approaches to instruction, criterion referenced testing, and performance oriented testing. These new approaches often emphasize individualized learning; each student's progress is individually monitored by comparison with clear statements of what…

  17. Performance Testing of Tracer Gas and Tracer Aerosol Detectors for use in Radionuclide NESHAP Compliance Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fuehne, David Patrick; Lattin, Rebecca Renee

    The Rad-NESHAP program, part of the Air Quality Compliance team of LANL’s Compliance Programs group (EPC-CP), and the Radiation Instrumentation & Calibration team, part of the Radiation Protection Services group (RP-SVS), frequently partner on issues relating to characterizing air flow streams. This memo documents the most recent example of this partnership, involving performance testing of sulfur hexafluoride detectors for use in stack gas mixing tests. Additionally, members of the Rad-NESHAP program performed a functional trending test on a pair of optical particle counters, comparing results from a non-calibrated instrument to a calibrated instrument. Prior to commissioning a new stack samplingmore » system, the ANSI Standard for stack sampling requires that the stack sample location must meet several criteria, including uniformity of tracer gas and aerosol mixing in the air stream. For these mix tests, tracer media (sulfur hexafluoride gas or liquid oil aerosol particles) are injected into the stack air stream and the resulting air concentrations are measured across the plane of the stack at the proposed sampling location. The coefficient of variation of these media concentrations must be under 20% when evaluated over the central 2/3 area of the stack or duct. The instruments which measure these air concentrations must be tested prior to the stack tests in order to ensure their linear response to varying air concentrations of either tracer gas or tracer aerosol. The instruments used in tracer gas and aerosol mix testing cannot be calibrated by the LANL Standards and Calibration Laboratory, so they would normally be sent off-site for factory calibration by the vendor. Operational requirements can prevent formal factory calibration of some instruments after they have been used in hazardous settings, e.g., within a radiological facility with potential airborne contamination. The performance tests described in this document are intended to demonstrate the

  18. The Dyad-Adaptive Paced Auditory Serial Addition Test (DA-PASAT): Normative data and the effects of repeated testing, simulated malingering, and traumatic brain injury

    PubMed Central

    Wyma, John M.; Herron, Timothy J.; Yund, E. William; Reed, Bruce

    2018-01-01

    The Paced Auditory Serial Addition Test (PASAT) is widely used to evaluate processing speed and executive function in patients with multiple sclerosis, traumatic brain injury, and other neurological disorders. In the PASAT, subjects listen to sequences of digits while continuously reporting the sum of the last two digits presented. Four different stimulus onset asynchronies (SOAs) are usually tested, with difficulty increasing as SOAs are reduced. Ceiling effects are common at long SOAs, while the digit delivery rate often exceeds the subject’s processing capacity at short SOAs, causing some subjects to stop performing altogether. In addition, subjects may adopt an “alternate answer” strategy at short SOAs, which reduces the test’s demands on working-memory and processing speed. Consequently, studies have shown that the number of dyads (consecutive correct answers) is a more sensitive measure of PASAT performance than the overall number of correct sums. Here, we describe a 2.5-minute computerized test, the Dyad-Adaptive PASAT (DA-PASAT), where SOAs are adjusted with a 2:1 staircase, decreasing after each pair of correct responses and increasing after misses. Processing capacity is reflected in the minimum SOA (minSOA) achieved in 54 trials. Experiment 1 gathered normative data in two large populations: 1617 subjects in New Zealand ranging in age from 18 to 65 years, and 214 Californians ranging in age from 18 to 82 years. Minimum SOAs were influenced by age, education, and daily hours of computer-use. Minimum SOA z-scores, calculated after factoring out the influence of these factors, were virtually identical in the two control groups, as were response times (RTs) and dyad ratios (the proportion of hits occurring in dyads). Experiment 2 measured the test-retest reliability of the DA-PASAT in 44 young subjects who underwent three test sessions at weekly intervals. High intraclass correlation coefficients (ICCs) were found for minSOAs (0.87), response times

  19. Word Memory Test Performance Across Cognitive Domains, Psychiatric Presentations, and Mild Traumatic Brain Injury.

    PubMed

    Rowland, Jared A; Miskey, Holly M; Brearly, Timothy W; Martindale, Sarah L; Shura, Robert D

    2017-05-01

    The current study addressed two aims: (i) determine how Word Memory Test (WMT) performance relates to test performance across numerous cognitive domains and (ii) evaluate how current psychiatric disorders or mild traumatic brain injury (mTBI) history affects performance on the WMT after excluding participants with poor symptom validity. Participants were 235 Iraq and Afghanistan-era veterans (Mage = 35.5) who completed a comprehensive neuropsychological battery. Participants were divided into two groups based on WMT performance (Pass = 193, Fail = 42). Tests were grouped into cognitive domains and an average z-score was calculated for each domain. Significant differences were found between those who passed and those who failed the WMT on the memory, attention, executive function, and motor output domain z-scores. WMT failure was associated with a larger performance decrement in the memory domain than the sensation or visuospatial-construction domains. Participants with a current psychiatric diagnosis or mTBI history were significantly more likely to fail the WMT, even after removing participants with poor symptom validity. Results suggest that the WMT is most appropriate for assessing validity in the domains of attention, executive function, motor output and memory, with little relationship to performance in domains of sensation or visuospatial-construction. Comprehensive cognitive batteries would benefit from inclusion of additional performance validity tests in these domains. Additionally, symptom validity did not explain higher rates of WMT failure in individuals with a current psychiatric diagnosis or mTBI history. Further research is needed to better understand how these conditions may affect WMT performance. Published by Oxford University Press 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  20. Effect of Fuel Additives on Spray Performance of Alternative Jet Fuels

    NASA Astrophysics Data System (ADS)

    Kannaiyan, Kumaran; Sadr, Reza

    2015-11-01

    Role of alternative fuels on reducing the combustion pollutants is gaining momentum in both land and air transport. Recent studies have shown that addition of nanoscale metal particles as fuel additives to liquid fuels have a positive effect not only on their combustion performance but also in reducing the pollutant formation. However, most of those studies are still in the early stages of investigation with the addition of nanoparticles at low weight percentages. Such an addition can affect the hydrodynamic and thermo-physical properties of the fuel. In this study, the near nozzle spray performance of gas-to-liquid jet fuel with and without the addition of alumina nanoparticles are investigated at macro- and microscopic levels using optical diagnostic techniques. At macroscopic level, the addition of nanoparticles is seen to enhance the sheet breakup process when compared to that of the base fuel. Furthermore, the microscopic spray characteristics such as droplet size and velocity are also found to be affected. Although the addition of nanoscale metal particles at low weight percentages does not affect the bulk fluid properties, the atomization process is found to be affected in the near nozzle region. Funded by Qatar National Research Fund.

  1. Computerized Tests of Team Performance and Crew Coordination Suitable for Military/Aviation Settings.

    PubMed

    Lawson, Ben D; Britt, Thomas W; Kelley, Amanda M; Athy, Jeremy R; Legan, Shauna M

    2017-08-01

    The coordination of team effort on shared tasks is an area of inquiry. A number of tests of team performance in challenging environments have been developed without comparison or standardization. This article provides a systematic review of the most accessible and usable low-to-medium fidelity computerized tests of team performance and determines which are most applicable to military- and aviation-relevant research, such as studies of group command, control, communication, and crew coordination. A search was conducted to identify computerized measures of team performance. In addition to extensive literature searches (DTIC, Psychinfo, PubMed), the authors reached out to team performance researchers at conferences and through electronic communication. Identified were 57 potential tests according to 6 specific selection criteria (e.g., the requirement for automated collection of team performance and coordination processes, the use of military-relevant scenarios). The following seven tests (listed alphabetically) were considered most suitable for military needs: Agent Enabled Decision Group Environment (AEDGE), C3Conflict, the C3 (Command, Control, & Communications) Interactive Task for Identifying Emerging Situations (NeoCITIES), Distributed Dynamic Decision Making (DDD), Duo Wondrous Original Method Basic Awareness/Airmanship Test (DuoWOMBAT), the Leader Development Simulator (LDS), and the Planning Task for Teams (PLATT). Strengths and weaknesses of these tests are described and recommendations offered to help researchers identify the test most suitable for their particular needs. Adoption of a few standard computerized test batteries to study team performance would facilitate the evaluation of interventions intended to enhance group performance in multiple challenging military and aerospace operational environments.Lawson BD, Britt TW, Kelley AM, Athy JR, Legan SM. Computerized tests of team performance and crew coordination suitable for military/aviation settings

  2. Collaborative Test Reviews: Student Performance

    ERIC Educational Resources Information Center

    Bhatia, Anuradha; Makela, Carole J.

    2010-01-01

    A group study method proved helpful in improving senior-level students' performance on unit tests through collaborative learning. Students of a History of Textiles course voluntarily attended study sessions to review course content and prepare for unit tests. The students who attended the group reviews scored better on tests than those who did…

  3. Test-retest reliability of the irrational performance beliefs inventory.

    PubMed

    Turner, M J; Slater, M J; Dixon, J; Miller, A

    2018-02-01

    The irrational performance beliefs inventory (iPBI) was developed to measure irrational beliefs within performance domains such as sport, academia, business, and the military. Past research indicates that the iPBI has good construct, concurrent, and predictive validity, but the test-retest reliability of the iPBI has not yet been examined. Therefore, in the present study the iPBI was administered to university sport and exercise students (n = 160) and academy soccer athletes (n = 75) at three-time points. Time point two occurred 7 days after time point one, and time point three occurred 21 days after time point two. In addition, social desirability was also measured. Repeated-measures MANCOVAs, intra-class coefficients, and Pearson's (r) correlations demonstrate that the iPBI has good test-retest reliability, with iPBI scores remaining stable across the three-time points. Pearson's correlation coefficients revealed no relationships between the iPBI and social desirability, indicating that the iPBI is not highly susceptible to response bias. The results are discussed with reference to the continued usage and development of the iPBI, and future research recommendations relating to the investigation of irrational performance beliefs are proposed.

  4. Performance Testing

    NASA Technical Reports Server (NTRS)

    1991-01-01

    Systems Technology, Inc., Hawthorne, CA, developed an electronic Critical Tracking Task (CTT) system that analyzes and rates a subject's visual/motor responses for Ames Research Center. Originally applied to measuring the effects of long term confinement in the mid 1960's, the CTT system is now marketed as FACTOR 1000 by Performance Factors, Inc. Alameda, CA, under a licensing agreement with Systems Technology. The system is a non-invasive, self-administered test that takes less than a minute and detects impairment from a broad range of causes, including stress, fatigue, illness, drugs, or alcohol. It is used daily by Old Town Trolley Tours, San Diego, CA, to assess each driver's physical coordination skills prior to the start of each shift. FACTOR 1000 reduces liabilities and costs related to accidents, and costs less than one dollar per day per employee. Performance Factors is now BioFactors, Inc.

  5. 40 CFR 141.719 - Additional filtration toolbox components.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... establish a quality control release value (QCRV) for a non-destructive performance test that demonstrates... test; and Cp = the filtrate concentration measured during the challenge test. Equivalent units must be... or the applicability of the non-destructive performance test and associated QCRV, additional...

  6. 40 CFR 141.719 - Additional filtration toolbox components.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... establish a quality control release value (QCRV) for a non-destructive performance test that demonstrates... test; and Cp = the filtrate concentration measured during the challenge test. Equivalent units must be... or the applicability of the non-destructive performance test and associated QCRV, additional...

  7. 40 CFR 141.719 - Additional filtration toolbox components.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... establish a quality control release value (QCRV) for a non-destructive performance test that demonstrates... test; and Cp = the filtrate concentration measured during the challenge test. Equivalent units must be... or the applicability of the non-destructive performance test and associated QCRV, additional...

  8. A Performance Comparison of Color Vision Tests for Military Screening.

    PubMed

    Walsh, David V; Robinson, James; Jurek, Gina M; Capó-Aponte, José E; Riggs, Daniel W; Temme, Leonard A

    2016-04-01

    Current color vision (CV) tests used for aviation screening in the U.S. Army only provide pass-fail results, and previous studies have shown variable sensitivity and specificity. The purpose of this study was to evaluate seven CV tests to determine an optimal CV test screener that potentially could be implemented by the U.S. Army. There were 133 subjects [65 Color Vision Deficits (CVD), 68 Color Vision Normal (CVN)] who performed all of the tests in one setting. CVD and CVN determination was initially assessed with the Oculus anomaloscope. Each test was administered monocularly and according to the test protocol. The main outcome measures were test sensitivity, specificity, and administration time (automated tests). Three of the four Pseudoisochromatic Plate (PIP) tests had a sensitivity/specificity > 0.90 OD/OS, whereas the FALANT tests had a sensitivity/specificity > 0.80 OD/OS. The Cone Contrast Test (CCT) demonstrated sensitivity/specificity > 0.90 OD/OS, whereas the Color Assessment and Diagnosis (CAD) test demonstrated sensitivity/specificity > 0.85 OD/OS. Comparison with the anomaloscope ("gold standard") revealed no significant difference of sensitivity and specificity OD/OS with the CCT, Dvorine PIP, and PIPC tests. Finally, the CCT administration time was significantly faster than the CAD test. The current U.S. Army CV screening tests demonstrated good sensitivity and specificity, as did the automated tests. In addition, some current PIP tests (Dvorine, PIPC), and the CCT performed no worse statistically than the anomaloscope with regard to sensitivity/specificity. The CCT letter presentation is randomized and results would not be confounded by potential memorization, or fading, of book plates.

  9. 30. GENERAL TEST ROOM IN 1946 ADDITION, FOURTH FLOOR, LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    30. GENERAL TEST ROOM IN 1946 ADDITION, FOURTH FLOOR, LOOKING WEST. ORIGINALLY HAD SUSPENDED ACOUSTICAL CEILINGS WITH FLOURESCENT LIGHTING AND ASPHALT MASTIC TILE FLOORS - Underwriters' Laboratories, 207-231 East Ohio Street, Chicago, Cook County, IL

  10. 14 CFR 43.15 - Additional performance rules for inspections.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... TRANSPORTATION AIRCRAFT MAINTENANCE, PREVENTIVE MAINTENANCE, REBUILDING, AND ALTERATION § 43.15 Additional..., or 135 of this chapter, shall— (1) Perform the inspection so as to determine whether the aircraft, or... accordance with the instructions and procedures set forth in the inspection program for the aircraft being...

  11. 14 CFR 43.15 - Additional performance rules for inspections.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... TRANSPORTATION AIRCRAFT MAINTENANCE, PREVENTIVE MAINTENANCE, REBUILDING, AND ALTERATION § 43.15 Additional..., or 135 of this chapter, shall— (1) Perform the inspection so as to determine whether the aircraft, or... accordance with the instructions and procedures set forth in the inspection program for the aircraft being...

  12. 14 CFR 43.15 - Additional performance rules for inspections.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... TRANSPORTATION AIRCRAFT MAINTENANCE, PREVENTIVE MAINTENANCE, REBUILDING, AND ALTERATION § 43.15 Additional..., or 135 of this chapter, shall— (1) Perform the inspection so as to determine whether the aircraft, or... accordance with the instructions and procedures set forth in the inspection program for the aircraft being...

  13. 14 CFR 43.15 - Additional performance rules for inspections.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... TRANSPORTATION AIRCRAFT MAINTENANCE, PREVENTIVE MAINTENANCE, REBUILDING, AND ALTERATION § 43.15 Additional..., or 135 of this chapter, shall— (1) Perform the inspection so as to determine whether the aircraft, or... accordance with the instructions and procedures set forth in the inspection program for the aircraft being...

  14. 14 CFR 43.15 - Additional performance rules for inspections.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... TRANSPORTATION AIRCRAFT MAINTENANCE, PREVENTIVE MAINTENANCE, REBUILDING, AND ALTERATION § 43.15 Additional..., or 135 of this chapter, shall— (1) Perform the inspection so as to determine whether the aircraft, or... accordance with the instructions and procedures set forth in the inspection program for the aircraft being...

  15. Price, performance, and the FDA approval process: the example of home HIV testing.

    PubMed

    Paltiel, A David; Pollack, Harold A

    2010-01-01

    The Food and Drug Administration (FDA) is considering approval of an over-the-counter, rapid HIV test for home use. To support its decision, the FDA seeks evidence of the test's performance. It has asked the manufacturer to conduct field studies of the test's sensitivity and specificity when employed by untrained users. In this article, the authors argue that additional information should be sought to evaluate the prevalence of undetected HIV in the end-user The analytic framework produces the elementary but counterintuitive finding that the performance of the home HIV test- measured in terms of its ability to correctly detect the presence and absence of HIV infection among the people who purchase it-depends critically on the manufacturer's retail price. This finding has profound implications for the FDA's approval process.

  16. Big Area Additive Manufacturing of High Performance Bonded NdFeB Magnets

    NASA Astrophysics Data System (ADS)

    Li, Ling; Tirado, Angelica; Nlebedim, I. C.; Rios, Orlando; Post, Brian; Kunc, Vlastimil; Lowden, R. R.; Lara-Curzio, Edgar; Fredette, Robert; Ormerod, John; Lograsso, Thomas A.; Paranthaman, M. Parans

    2016-10-01

    Additive manufacturing allows for the production of complex parts with minimum material waste, offering an effective technique for fabricating permanent magnets which frequently involve critical rare earth elements. In this report, we demonstrate a novel method - Big Area Additive Manufacturing (BAAM) - to fabricate isotropic near-net-shape NdFeB bonded magnets with magnetic and mechanical properties comparable or better than those of traditional injection molded magnets. The starting polymer magnet composite pellets consist of 65 vol% isotropic NdFeB powder and 35 vol% polyamide (Nylon-12). The density of the final BAAM magnet product reached 4.8 g/cm3, and the room temperature magnetic properties are: intrinsic coercivity Hci = 688.4 kA/m, remanence Br = 0.51 T, and energy product (BH)max = 43.49 kJ/m3 (5.47 MGOe). In addition, tensile tests performed on four dog-bone shaped specimens yielded an average ultimate tensile strength of 6.60 MPa and an average failure strain of 4.18%. Scanning electron microscopy images of the fracture surfaces indicate that the failure is primarily related to the debonding of the magnetic particles from the polymer binder. The present method significantly simplifies manufacturing of near-net-shape bonded magnets, enables efficient use of rare earth elements thus contributing towards enriching the supply of critical materials.

  17. Big area additive manufacturing of high performance bonded NdFeB magnets

    DOE PAGES

    Li, Ling; Tirado, Angelica; Nlebedim, I. C.; ...

    2016-10-31

    Additive manufacturing allows for the production of complex parts with minimum material waste, offering an effective technique for fabricating permanent magnets which frequently involve critical rare earth elements. In this report, we demonstrate a novel method - Big Area Additive Manufacturing (BAAM) - to fabricate isotropic near-net-shape NdFeB bonded magnets with magnetic and mechanical properties comparable or better than those of traditional injection molded magnets. The starting polymer magnet composite pellets consist of 65 vol% isotropic NdFeB powder and 35 vol% polyamide (Nylon-12). The density of the final BAAM magnet product reached 4.8 g/cm3, and the room temperature magnetic propertiesmore » are: intrinsic coercivity Hci = 688.4 kA/m, remanence B r = 0.51 T, and energy product (BH) max = 43.49 kJ/m 3 (5.47 MGOe). In addition, tensile tests performed on four dog-bone shaped specimens yielded an average ultimate tensile strength of 6.60 MPa and an average failure strain of 4.18%. Scanning electron microscopy images of the fracture surfaces indicate that the failure is primarily related to the debonding of the magnetic particles from the polymer binder. As a result, the present method significantly simplifies manufacturing of near-net-shape bonded magnets, enables efficient use of rare earth elements thus contributing towards enriching the supply of critical materials.« less

  18. Big area additive manufacturing of high performance bonded NdFeB magnets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Ling; Tirado, Angelica; Nlebedim, I. C.

    Additive manufacturing allows for the production of complex parts with minimum material waste, offering an effective technique for fabricating permanent magnets which frequently involve critical rare earth elements. In this report, we demonstrate a novel method - Big Area Additive Manufacturing (BAAM) - to fabricate isotropic near-net-shape NdFeB bonded magnets with magnetic and mechanical properties comparable or better than those of traditional injection molded magnets. The starting polymer magnet composite pellets consist of 65 vol% isotropic NdFeB powder and 35 vol% polyamide (Nylon-12). The density of the final BAAM magnet product reached 4.8 g/cm3, and the room temperature magnetic propertiesmore » are: intrinsic coercivity Hci = 688.4 kA/m, remanence B r = 0.51 T, and energy product (BH) max = 43.49 kJ/m 3 (5.47 MGOe). In addition, tensile tests performed on four dog-bone shaped specimens yielded an average ultimate tensile strength of 6.60 MPa and an average failure strain of 4.18%. Scanning electron microscopy images of the fracture surfaces indicate that the failure is primarily related to the debonding of the magnetic particles from the polymer binder. As a result, the present method significantly simplifies manufacturing of near-net-shape bonded magnets, enables efficient use of rare earth elements thus contributing towards enriching the supply of critical materials.« less

  19. The use of the rapid osmotic fragility test as an additional test to diagnose canine immune-mediated haemolytic anaemia

    PubMed Central

    2013-01-01

    Background Diagnosing canine immune-mediated haemolytic anaemia (IMHA) is often challenging because all currently available tests have their limitations. Dogs with IMHA often have an increased erythrocyte osmotic fragility (OF), a characteristic that is sometimes used in the diagnosis of IMHA. Since the classic osmotic fragility test (COFT) is time-consuming and requires specialized equipment, an easy and less labour-intensive rapid osmotic fragility test (ROFT) has been used in some countries, but its diagnostic value has not yet been investigated. This study aimed to evaluate erythrocyte osmotic fragility in dogs with and without IMHA, to compare results of the classic (COFT) and rapid (ROFT) test and to assess the value of the ROFT as diagnostic test for canine IMHA. Nineteen dogs with IMHA (group 1a), 21 anaemic dogs without IMHA (group 1b), 8 dogs with microcytosis (group 2), 13 hyperlipemic dogs (group 3), 10 dogs with lymphoma (group 4), 8 dogs with an infection (group 5) and 13 healthy dogs (group 6) were included. In all dogs, blood smear examination, in-saline auto-agglutination test, Coombs’ test, COFT and ROFT were performed. In the COFT, OF5, OF50 and OF90 were defined as the NaCl concentrations at which respectively 5, 50 and 90% of erythrocytes were haemolysed. Results Compared with healthy dogs, OF5 and OF50 were significantly higher in group 1a (P < 0.001) and OF5 was significantly higher in group 3 (P = 0.0266). The ROFT was positive in 17 dogs with IMHA, 10 hyperlipemic dogs, one anaemic dog without IMHA and one healthy dog. Conclusions Osmotic fragility was increased in the majority of dogs with IMHA and in dogs with hyperlipidemia, but not in dogs with microcytosis, lymphoma or an infection. Although more detailed information was obtained about the osmotic fragility by using the COFT, the COFT and ROFT gave similar results. The ROFT does not require specialized equipment, is rapid and easy to perform and can be used easily in daily

  20. Sensitivity to change of the field-based Wheelchair Mobility Performance Test in wheelchair basketball.

    PubMed

    de Witte, Annemarie M H; Sjaarda, Fleur; Helleman, Jochem; Berger, Monique A M; van der Woude, Lucas H V; Hoozemans, Marco J M

    2018-06-15

    The Wheelchair Mobility Performance (WMP) test is a reliable and valid measure to assess mobility performance in wheelchair basketball. The aim of this study was to examine the sensitivity to change of the WMP test by manipulating wheelchair configurations. Sixteen wheelchair basketball players performed the WMP test 3 times in their own wheelchair: (i) without adjustments ("control condition"); (ii) with 10 kg additional mass ("weighted condition"); and (iii) with 50% reduced tyre pressure ("tyre condition"). The outcome measure was time (s). If paired t-tests were significant (p <0.05) and differences between conditions were larger than the standard error of measurement, the effect sizes (ES) were used to evaluate the sensitivity to change. ES values ≥0.2 were regarded as sensitive to change. The overall performance times for the manipulations were significantly higher than the control condition, with mean differences of 4.40 s (weight - control, ES = 0.44) and 2.81 s (tyre - control, ES = 0.27). The overall performance time on the WMP test was judged as sensitive to change. For 8 of the 15 separate tasks on the WMP test, the tasks were judged as sensitive to change for at least one of the manipulations. The WMP test can detect change in mobility performance when wheelchair configurations are manipulated.

  1. Development of Flight-Test Performance Estimation Techniques for Small Unmanned Aerial Systems

    NASA Astrophysics Data System (ADS)

    McCrink, Matthew Henry

    This dissertation provides a flight-testing framework for assessing the performance of fixed-wing, small-scale unmanned aerial systems (sUAS) by leveraging sub-system models of components unique to these vehicles. The development of the sub-system models, and their links to broader impacts on sUAS performance, is the key contribution of this work. The sub-system modeling and analysis focuses on the vehicle's propulsion, navigation and guidance, and airframe components. Quantification of the uncertainty in the vehicle's power available and control states is essential for assessing the validity of both the methods and results obtained from flight-tests. Therefore, detailed propulsion and navigation system analyses are presented to validate the flight testing methodology. Propulsion system analysis required the development of an analytic model of the propeller in order to predict the power available over a range of flight conditions. The model is based on the blade element momentum (BEM) method. Additional corrections are added to the basic model in order to capture the Reynolds-dependent scale effects unique to sUAS. The model was experimentally validated using a ground based testing apparatus. The BEM predictions and experimental analysis allow for a parameterized model relating the electrical power, measurable during flight, to the power available required for vehicle performance analysis. Navigation system details are presented with a specific focus on the sensors used for state estimation, and the resulting uncertainty in vehicle state. Uncertainty quantification is provided by detailed calibration techniques validated using quasi-static and hardware-in-the-loop (HIL) ground based testing. The HIL methods introduced use a soft real-time flight simulator to provide inertial quality data for assessing overall system performance. Using this tool, the uncertainty in vehicle state estimation based on a range of sensors, and vehicle operational environments is

  2. Tethered Swimming Test: Reliability and the Association to Swimming Performance and Land-based Anaerobic Performance.

    PubMed

    Nagle Zera, Jacquelyn; Nagle, Elizabeth F; Nagai, Takashi; Lovalekar, Mita; Abt, John P; Lephart, Scott M

    2018-02-14

    The purpose of this study was three-fold: (a) to examine the test-retest reliability of a 30 second maximal tethered freestyle swimming test (TST), (b) to assess the validity of the TST by examining the association to sprint swimming performance and, (c) to examine the associations between a swim-specific and land-based measure of anaerobic performance. A total of twenty-nine male and female swimmers were recruited to participate in the study. Each participant completed a Wingate Anaerobic cycling test (WAnT), two or four TST, and a 22.9 meter (25 yard), 45.7 meter (50 yard), and 91.4 meter (100 yard) maximal freestyle performance swims (PS). Mean and peak force (Fmean, Fpeak) were recorded for both the WAnT and TST, and average swimming velocity and time were recorded for the PS. Additionally, physiological and perceptual measures were recorded immediate post exercise for all tests. The results of the present investigation showed strong intersession and intrasession reliability (R= 0.821-0.975; p<0.001) for force parameters of the TST. Moderate correlations were found between Fmean and PS time and velocity of all distances, with slightly weaker correlations between Fpeak and the 22.9 meter (time and velocity) and 45.7 meter (velocity) PS. Finally, moderate correlations were found for Fmean and Fpeak of the TST and WAnT. This study demonstrated that the TST is a reliable measure, with moderate association to swimming performance, producing similar physiological responses compared to free swimming. Therefore, future research shoulSd focus on investigating the potential benefits of utilizing the TST as a regular assessment tool as a part of a competitive swimming training program to track adaptations and inform training decisions.

  3. Proctored and Unproctored Test Performance

    ERIC Educational Resources Information Center

    Brallier, Sara; Palm, Linda

    2015-01-01

    This study examined test performance as a function of test format (proctored versus unproctored) and course type (traditional versus distance). The participants were 246 undergraduate students who completed introductory sociology courses during four semesters at a southeastern university. During each semester, the same instructor taught a…

  4. 40 CFR 63.827 - Performance test methods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Performance test methods. 63.827...) National Emission Standards for the Printing and Publishing Industry § 63.827 Performance test methods... test method for determining their values for approval by the Administrator in accordance with § 63.7(f...

  5. Robustness of statistical tests for multiplicative terms in the additive main effects and multiplicative interaction model for cultivar trials.

    PubMed

    Piepho, H P

    1995-03-01

    The additive main effects multiplicative interaction model is frequently used in the analysis of multilocation trials. In the analysis of such data it is of interest to decide how many of the multiplicative interaction terms are significant. Several tests for this task are available, all of which assume that errors are normally distributed with a common variance. This paper investigates the robustness of several tests (Gollob, F GH1, FGH2, FR)to departures from these assumptions. It is concluded that, because of its better robustness, the F Rtest is preferable. If the other tests are to be used, preliminary tests for the validity of assumptions should be performed.

  6. Ultimate strength performance of tankers associated with industry corrosion addition practices

    NASA Astrophysics Data System (ADS)

    Kim, Do Kyun; Kim, Han Byul; Zhang, Xiaoming; Li, Chen Guang; Paik, Jeom Kee

    2014-09-01

    In the ship and offshore structure design, age-related problems such as corrosion damage, local denting, and fatigue damage are important factors to be considered in building a reliable structure as they have a significant influence on the residual structural capacity. In shipping, corrosion addition methods are widely adopted in structural design to prevent structural capacity degradation. The present study focuses on the historical trend of corrosion addition rules for ship structural design and investigates their effects on the ultimate strength performance such as hull girder and stiffened panel of double hull oil tankers. Three types of rules based on corrosion addition models, namely historic corrosion rules (pre-CSR), Common Structural Rules (CSR), and harmonised Common Structural Rules (CSRH) are considered and compared with two other corrosion models namely UGS model, suggested by the Union of Greek Shipowners (UGS), and Time-Dependent Corrosion Wastage Model (TDCWM). To identify the general trend in the effects of corrosion damage on the ultimate longitudinal strength performance, the corrosion addition rules are applied to four representative sizes of double hull oil tankers namely Panamax, Aframax, Suezmax, and VLCC. The results are helpful in understanding the trend of corrosion additions for tanker structures

  7. Paced Auditory Serial Addition Test (PASAT 3.0 s): Demographically corrected norms for the Portuguese population.

    PubMed

    Sousa, Claudia Sofia; Neves, Mariana Rigueiro; Passos, Ana Margarida; Ferreira, Aristides; Sá, Maria José

    2017-05-23

    The main goal of this study was to produce adjusted normative data for the Portuguese population on the Paced Auditory Serial Addition Test (PASAT 3.0 s), the version used in the Brief Repeatable Battery of Neuropsychological Tests developed by the National Multiple Sclerosis Society. The study included 326 community-dwelling individuals (199 women and 127 men) aged between 20 and 70 (mean = 40.33, SD = 14.40), who had educational backgrounds ranging from 4 to 23 years of schooling (mean = 12.28, SD = 4.39). Age, gender and qualifications revealed differences in explaining their performance on the PASAT 3.0 s. Men had significantly better performance on the PASAT 3.0 s than women, even though this represents a small effect size r = 0.18. Demographically corrected normative data was developed and important information regarding performance on the PASAT 3.0 s test is provided. Results are discussed and presented in tables and a formula is presented for computing age, gender and education adjusted T-scores for performance on the PASAT 3.0 s. These results should be considered as useful reference values for clinicians and investigators when applying the PASAT 3.0 s to assess cognitive function like information processing speed in different pathologies.

  8. Results of Performance Tests Performed on the John Watts WW Casing Connection on 7" Pipe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    John D. Watts

    2000-02-01

    lubricant applied to the connection by applying it to the box or pin only and reducing the amount applied. Samples 3 and 4 received one makeup only. Sample 5 initially received two make/breaks to test for galling resistance before final makeup, No galling was observed. Later, three additional make/breaks were performed with no pin end collapse and galling over 1/2 a thread occurring on one of the breakouts. During the make/break tests, the stabbing and hand tight makeup of the WW connection was found to be very easy and trouble free. There was no tendency to crossthread, even when stabbed at an angle, and it screwed together very smoothly up to hand tight. During power tight makeup, there was no heat generated in the box (as checked by hand contact) and no jerkiness associated with any of the makeups or breakouts. Sample 2 was tested in pure compression. The maximum load obtained was 1,051 kips and the connection was beginning to significantly deform as the sample buckled. Actual pipe yield was 1,226 kips. Sample 3 was capped-end pressure tested to failure. The capped-end yield pressure of the pipe was 16,572 psi and the sample began to leak at 12,000 psi. Sample 4 was tested in pure tension. The maximum load obtained was 978 kips and the connection failed by fracture at the pin critical section. Actual pipe yield was 1,226 kips. Sample 5 was tested in combined tension/compression and internal gas pressure. The sample was assembled, setup and tested four times. The first time was with a torque of 7,298 ft-lbs and the connection leaked halfway to ISO Load Point 2 with loads of 693 kips and 4,312 psi. The second time the torque was increased to 14,488 ft-lbs and a leak occurred at 849 kips and 9,400 psi, which was ISO Load Point 2. The third time the makeup torque was again increased, to 20,456 ft-lbs, and a leak occurred at 716 kips and 11,342 psi, ISO Load Point 4. The fourth test was with the same torque as before, 20,617 ft-lbs, and the connection successfully tested up

  9. The Ling 6(HL) test: typical pediatric performance data and clinical use evaluation.

    PubMed

    Glista, Danielle; Scollie, Susan; Moodie, Sheila; Easwar, Vijayalakshmi

    2014-01-01

    The Ling 6(HL) test offers a calibrated version of naturally produced speech sounds in dB HL for evaluation of detection thresholds. Aided performance has been previously characterized in adults. The purpose of this work was to evaluate and refine the Ling 6(HL) test for use in pediatric hearing aid outcome measurement. This work is presented across two studies incorporating an integrated knowledge translation approach in the characterization of normative and typical performance, and in the evaluation of clinical feasibility, utility, acceptability, and implementation. A total of 57 children, 28 normally hearing and 29 with binaural sensorineural hearing loss, were included in Study 1. Children wore their own hearing aids fitted using Desired Sensation Level v5.0. Nine clinicians from The Network of Pediatric Audiologists participated in Study 2. A CD-based test format was used in the collection of unaided and aided detection thresholds in laboratory and clinical settings; thresholds were measured clinically as part of routine clinical care. Confidence intervals were derived to characterize normal performance and typical aided performance according to hearing loss severity. Unaided-aided performance was analyzed using a repeated-measures analysis of variance. The audiologists completed an online questionnaire evaluating the quality, feasibility/executability, utility/comparative value/relative advantage, acceptability/applicability, and interpretability, in addition to recommendation and general comments sections. Ling 6(HL) thresholds were reliably measured with children 3-18 yr old. Normative and typical performance ranges were translated into a scoring tool for use in pediatric outcome measurement. In general, questionnaire respondents generally agreed that the Ling 6(HL) test was a high-quality outcome evaluation tool that can be implemented successfully in clinical settings. By actively collaborating with pediatric audiologists and using an integrated

  10. Performance testing and results of the first Etec CORE-2564

    NASA Astrophysics Data System (ADS)

    Franks, C. Edward; Shikata, Asao; Baker, Catherine A.

    1993-03-01

    In order to be able to write 64 megabit DRAM reticles, to prepare to write 256 megabit DRAM reticles and in general to meet the current and next generation mask and reticle quality requirements, Hoya Micro Mask (HMM) installed in 1991 the first CORE-2564 Laser Reticle Writer from Etec Systems, Inc. The system was delivered as a CORE-2500XP and was subsequently upgraded to a 2564. The CORE (Custom Optical Reticle Engraver) system produces photomasks with an exposure strategy similar to that employed by an electron beam system, but it uses a laser beam to deliver the photoresist exposure energy. Since then the 2564 has been tested by Etec's standard Acceptance Test Procedure and by several supplementary HMM techniques to insure performance to all the Etec advertised specifications and certain additional HMM requirements that were more demanding and/or more thorough than the advertised specifications. The primary purpose of the HMM tests was to more closely duplicate mask usage. The performance aspects covered by the tests include registration accuracy and repeatability; linewidth accuracy, uniformity and linearity; stripe butting; stripe and scan linearity; edge quality; system cleanliness; minimum geometry resolution; minimum address size and plate loading accuracy and repeatability.

  11. Astronaut Scott Carpenter tests balance mechanism performance

    NASA Technical Reports Server (NTRS)

    1961-01-01

    Astronaut M. Scott Carpenter's balance mechanism performance is tested by his walking on a narrow board in his bare feet. He is performing this test at the School of Aviation Medicine, Pensicola, Florida (04570); Carpenter walks a straight line by putting one foot directly in front of the other to test his balance (04571).

  12. Performance testing for superpave and structural validation.

    DOT National Transportation Integrated Search

    2012-11-01

    The primary objective of this full-scale accelerated pavement testing was to evaluate the performance of unmodified : and polymer modified asphalt binders and to recommend improved specification tests over existing SUperior : PERforming Asphalt PAVEm...

  13. Providing Extrinsic Reward for Test Performance Undermines Long-Term Memory Acquisition.

    PubMed

    Kuhbandner, Christof; Aslan, Alp; Emmerdinger, Kathrin; Murayama, Kou

    2016-01-01

    Based on numerous studies showing that testing studied material can improve long-term retention more than restudying the same material, it is often suggested that the number of tests in education should be increased to enhance knowledge acquisition. However, testing in real-life educational settings often entails a high degree of extrinsic motivation of learners due to the common practice of placing important consequences on the outcome of a test. Such an effect on the motivation of learners may undermine the beneficial effects of testing on long-term memory because it has been shown that extrinsic motivation can reduce the quality of learning. To examine this issue, participants learned foreign language vocabulary words, followed by an immediate test in which one-third of the words were tested and one-third restudied. To manipulate extrinsic motivation during immediate testing, participants received either monetary reward contingent on test performance or no reward. After 1 week, memory for all words was tested. In the immediate test, reward reduced correct recall and increased commission errors, indicating that reward reduced the number of items that can benefit from successful retrieval. The results in the delayed test revealed that reward additionally reduced the gain received from successful retrieval because memory for initially successfully retrieved words was lower in the reward condition. However, testing was still more effective than restudying under reward conditions because reward undermined long-term memory for concurrently restudied material as well. These findings indicate that providing performance-contingent reward in a test can undermine long-term knowledge acquisition.

  14. Does Test Item Performance Increase with Test-to-Standards Alignment?

    ERIC Educational Resources Information Center

    Traynor, Anne

    2017-01-01

    Variation in test performance among examinees from different regions or national jurisdictions is often partially attributed to differences in the degree of content correspondence between local school or training program curricula, and the test of interest. This posited relationship between test-curriculum correspondence, or "alignment,"…

  15. High Energy Density Additives for Hybrid Fuel Rockets to Improve Performance and Enhance Safety

    NASA Technical Reports Server (NTRS)

    Jaffe, Richard L.

    2014-01-01

    We propose a conceptual study of prototype strained hydrocarbon molecules as high energy density additives for hybrid rocket fuels to boost the performance of these rockets without compromising safety and reliability. Use of these additives could extend the range of applications for which hybrid rockets become an attractive alternative to conventional solid or liquid fuel rockets. The objectives of the study were to confirm and quantify the high enthalpy of these strained molecules and to assess improvement in rocket performance that would be expected if these additives were blended with conventional fuels. We confirmed the chemical properties (including enthalpy) of these additives. However, the predicted improvement in rocket performance was too small to make this a useful strategy for boosting hybrid rocket performance.

  16. Functional performance testing for power and return to sports.

    PubMed

    Manske, Robert; Reiman, Michael

    2013-05-01

    Functional performance testing of athletes can determine physical limitations that may affect sporting activities. Optimal functional performance testing simulates the athlete's activity. A Medline search from 1960 to 2012 was implemented with the keywords functional testing, functional impairment testing, and functional performance testing in the English language. Each author also undertook independent searches of article references. Functional performance tests can bridge the gap between general physical tests and full, unrestricted athletic activity.

  17. Combustion Performance of a Staged Hybrid Rocket with Boron addition

    NASA Astrophysics Data System (ADS)

    Lee, D.; Lee, C.

    2018-04-01

    In this paper, the effect of boron on overall system specific impulse was investigated. Additionally, a series of combustion tests was carried out to analyze and evaluate the effect of boron addition on O/F variation and radial temperature profiles. To maintain the hybrid rocket engine advantages, upper limit of boron contents in solid fuel was set to be 10 wt%. The results also suggested that, when adding boron to solid fuel, it helped to provide more uniform radial temperature distribution and also to increase specific impulse by 3.2%.

  18. Personalized Progressive Addition Lenses: Correlation between Performance and Design.

    PubMed

    Forkel, Johanne; Reiniger, Jenny Lorén; Muschielok, Adam; Welk, Andrea; Seidemann, Anne; Baumbach, Peter

    2017-02-01

    A continuous set of personalized designs (design space) for progressive addition lenses (PALs) is investigated. The main goals are (1) to study how the subjects' perception of a personalized design depends on its position in the design space and (2) to compare the performance of personalized PALs to a conventional PAL with a fixed design. In a double-blind study, 51 subjects compared Rodenstock Impression FreeSign 3, which is a family of PALs with a continuously controllable personalized design, and Rodenstock Progressiv Life Free, which is a conventional PAL with a single fixed design. The positions and sizes of viewing zones and the softness of gradients of mean power and astigmatism of personalized lenses were customized to individual viewing preferences. These designs were represented as points in a design space comprising a continuum of PAL designs. Subjective ratings and experimental measurements were used to study viewing zone widths, blur gradient smoothness, amount of distortion, the feeling of safety during motion, and overall wearing comfort. (1) Far viewing zone width (experiments and ratings), near viewing zone width (experiments), blur gradient smoothness, and the amount of distortion (ratings) were significantly dependent on the position of the personalized lens design in the design space. This was consistent with the structure of the design space. (2) 82% of the subjects chose personalized lenses as their favorite. Most subjects reported higher wearing comfort and tolerability with personalized lenses than with conventional lenses. The designs of the tested personalized lenses were perceived by the subjects as intended. This is a prerequisite to the successful customization of PALs to individual wearing preferences. Possible reasons for the preference of the tested personalized lenses are the optimization with respect to individual wearing conditions and the personalization.

  19. The Semiautomated Test System: A Tool for Standardized Performance Testing.

    ERIC Educational Resources Information Center

    Ramsey, H. Rudy

    For performance tests to be truly standardized, they must be administered in a way that will minimize variation due to operator intervention and errors. Through such technological developments as low-cost digital computers and digital logic modules, automatic test administration without restriction of test content has become possible. A…

  20. A Comprehensive Review of Effect of Biodiesel Additives on Properties, Performance, and Emission

    NASA Astrophysics Data System (ADS)

    Madiwale, S.; Karthikeyan, A.; Bhojwani, V.

    2017-05-01

    Objectives:- To presents the literature review on effect of biodiesel additives on properties, performance and on emission. Method:-In the current paper reviews are taken from previous years paper which necessitates the need of addition of additives in the blends of biodiesel and studied the its effect on properties, performance and emissions. Emissions from the diesel powered vehicles mostly damaged the earth’s environment and also increased the overall earth’s temperature. This attracts the need of alternative fuels in the field of transportation sector. Past inventions and research showed that Biodiesel can be used as an alternative fuel for the diesel engine. Biodiesel have good combustion characteristics because of their long chain hydrocarbon structure. However biodiesel possesses few disadvantages such as lower heating value, higher flow ability, much high density and not able to flow at low temperature. Higher rate of fuel consumption is identified and higher level of NOx emissions when biodiesel used in an engine as an alternative fuels. Findings:-Different additives such as antioxidants, improvers for cetane number, cold flow properties improver, etc were investigated by the many researcher and scientists and added in the different feedstock of biodiesel or blends of biodiesel with diesel in different proportions. Directly or indirectly fuel additives can improve the reduction in the emissions, improve the fuel economy, and reduce the dependency of the one’s nation on other. Performances of biodiesel vehicles were drastically improved because of additioninthe blends of biodiesel with diesel fuel in specific percentages to meet the international emission standards. Addition of additives in the biodiesel or in the blends of biodiesel basically changes the high temperature and low temperature flow properties of blends of biodiesel. Current paper finds and compares properties of different additives and its effect on blends of biodiesel properties

  1. Functional Performance Testing for Power and Return to Sports

    PubMed Central

    Manske, Robert; Reiman, Michael

    2013-01-01

    Context: Functional performance testing of athletes can determine physical limitations that may affect sporting activities. Optimal functional performance testing simulates the athlete’s activity. Evidence Acquisition: A Medline search from 1960 to 2012 was implemented with the keywords functional testing, functional impairment testing, and functional performance testing in the English language. Each author also undertook independent searches of article references. Conclusion: Functional performance tests can bridge the gap between general physical tests and full, unrestricted athletic activity. PMID:24427396

  2. Application of historical mobility testing to sensor-based robotic performance

    NASA Astrophysics Data System (ADS)

    Willoughby, William E.; Jones, Randolph A.; Mason, George L.; Shoop, Sally A.; Lever, James H.

    2006-05-01

    The USA Engineer Research and Development Center (ERDC) has conducted on-/off-road experimental field testing with full-sized and scale-model military vehicles for more than fifty years. Some 4000 acres of local terrain are available for tailored field evaluations or verification/validation of future robotic designs in a variety of climatic regimes. Field testing and data collection procedures, as well as techniques for quantifying terrain in engineering terms, have been developed and refined into algorithms and models for predicting vehicle-terrain interactions and resulting forces or speeds of military-sized vehicles. Based on recent experiments with Matilda, Talon, and Pacbot, these predictive capabilities appear to be relevant to most robotic systems currently in development. Utilization of current testing capabilities with sensor-based vehicle drivers, or use of the procedures for terrain quantification from sensor data, would immediately apply some fifty years of historical knowledge to the development, refinement, and implementation of future robotic systems. Additionally, translation of sensor-collected terrain data into engineering terms would allow assessment of robotic performance a priori deployment of the actual system and ensure maximum system performance in the theater of operation.

  3. Big Area Additive Manufacturing of High Performance Bonded NdFeB Magnets

    PubMed Central

    Li, Ling; Tirado, Angelica; Nlebedim, I. C.; Rios, Orlando; Post, Brian; Kunc, Vlastimil; Lowden, R. R.; Lara-Curzio, Edgar; Fredette, Robert; Ormerod, John; Lograsso, Thomas A.; Paranthaman, M. Parans

    2016-01-01

    Additive manufacturing allows for the production of complex parts with minimum material waste, offering an effective technique for fabricating permanent magnets which frequently involve critical rare earth elements. In this report, we demonstrate a novel method - Big Area Additive Manufacturing (BAAM) - to fabricate isotropic near-net-shape NdFeB bonded magnets with magnetic and mechanical properties comparable or better than those of traditional injection molded magnets. The starting polymer magnet composite pellets consist of 65 vol% isotropic NdFeB powder and 35 vol% polyamide (Nylon-12). The density of the final BAAM magnet product reached 4.8 g/cm3, and the room temperature magnetic properties are: intrinsic coercivity Hci = 688.4 kA/m, remanence Br = 0.51 T, and energy product (BH)max = 43.49 kJ/m3 (5.47 MGOe). In addition, tensile tests performed on four dog-bone shaped specimens yielded an average ultimate tensile strength of 6.60 MPa and an average failure strain of 4.18%. Scanning electron microscopy images of the fracture surfaces indicate that the failure is primarily related to the debonding of the magnetic particles from the polymer binder. The present method significantly simplifies manufacturing of near-net-shape bonded magnets, enables efficient use of rare earth elements thus contributing towards enriching the supply of critical materials. PMID:27796339

  4. Big Area Additive Manufacturing of High Performance Bonded NdFeB Magnets.

    PubMed

    Li, Ling; Tirado, Angelica; Nlebedim, I C; Rios, Orlando; Post, Brian; Kunc, Vlastimil; Lowden, R R; Lara-Curzio, Edgar; Fredette, Robert; Ormerod, John; Lograsso, Thomas A; Paranthaman, M Parans

    2016-10-31

    Additive manufacturing allows for the production of complex parts with minimum material waste, offering an effective technique for fabricating permanent magnets which frequently involve critical rare earth elements. In this report, we demonstrate a novel method - Big Area Additive Manufacturing (BAAM) - to fabricate isotropic near-net-shape NdFeB bonded magnets with magnetic and mechanical properties comparable or better than those of traditional injection molded magnets. The starting polymer magnet composite pellets consist of 65 vol% isotropic NdFeB powder and 35 vol% polyamide (Nylon-12). The density of the final BAAM magnet product reached 4.8 g/cm 3 , and the room temperature magnetic properties are: intrinsic coercivity H ci  = 688.4 kA/m, remanence B r  = 0.51 T, and energy product (BH) max  = 43.49 kJ/m 3 (5.47 MGOe). In addition, tensile tests performed on four dog-bone shaped specimens yielded an average ultimate tensile strength of 6.60 MPa and an average failure strain of 4.18%. Scanning electron microscopy images of the fracture surfaces indicate that the failure is primarily related to the debonding of the magnetic particles from the polymer binder. The present method significantly simplifies manufacturing of near-net-shape bonded magnets, enables efficient use of rare earth elements thus contributing towards enriching the supply of critical materials.

  5. Performance evolution of 60 kA HTS cable prototypes in the EDIPO test facility

    NASA Astrophysics Data System (ADS)

    Bykovsky, N.; Uglietti, D.; Sedlak, K.; Stepanov, B.; Wesche, R.; Bruzzone, P.

    2016-08-01

    During the first test campaign of the 60 kA HTS cable prototypes in the EDIPO test facility, the feasibility of a novel HTS fusion cable concept proposed at the EPFL Swiss Plasma Center (SPC) was successfully demonstrated. While the measured DC performance of the prototypes at magnetic fields from 8 T to 12 T and for currents from 30 kA to 70 kA was close to the expected one, an initial electromagnetic cycling test (1000 cycles) revealed progressive degradation of the performance in both the SuperPower and SuperOx conductors. Aiming to understand the reasons for the degradation, additional cycling (1000 cycles) and warm up-cool down tests were performed during the second test campaign. I c performance degradation of the SuperOx conductor reached ∼20% after about 2000 cycles, which was reason to continue with a visual inspection of the conductor and further tests at 77 K. AC tests were carried out at 0 and 2 T background fields without transport current and at 10 T/50 kA operating conditions. Results obtained in DC and AC tests of the second test campaign are presented and compared with appropriate data published recently. Concluding the first iteration of the HTS cable development program at SPC, a summary and recommendations for the next activity within the HTS fusion cable project are also reported.

  6. Virtual Shaker Testing: Simulation Technology Improves Vibration Test Performance

    NASA Technical Reports Server (NTRS)

    Ricci, Stefano; Peeters, Bart; Fetter, Rebecca; Boland, Doug; Debille, Jan

    2008-01-01

    In the field of vibration testing, the interaction between the structure being tested and the instrumentation hardware used to perform the test is a critical issue. This is particularly true when testing massive structures (e.g. satellites), because due to physical design and manufacturing limits, the dynamics of the testing facility often couples with the test specimen one in the frequency range of interest. A further issue in this field is the standard use of a closed loop real-time vibration control scheme, which could potentially shift poles and change damping of the aforementioned coupled system. Virtual shaker testing is a novel approach to deal with these issues. It means performing a simulation which closely represents the real vibration test on the specific facility by taking into account all parameters which might impact the dynamic behavior of the specimen. In this paper, such a virtual shaker testing approach is developed. It consists of the following components: (1) Either a physical-based or an equation-based coupled electro-mechanical lumped parameter shaker model is created. The model parameters are obtained from manufacturer's specifications or by carrying out some dedicated experiments; (2) Existing real-time vibration control algorithm are ported to the virtual simulation environment; and (3) A structural model of the test object is created and after defining proper interface conditions structural modes are computed by means of the well-established Craig-Bampton CMS technique. At this stage, a virtual shaker test has been run, by coupling the three described models (shaker, control loop, structure) in a co-simulation routine. Numerical results have eventually been correlated with experimental ones in order to assess the robustness of the proposed methodology.

  7. Research of laser stealth performance test technology

    NASA Astrophysics Data System (ADS)

    Chen, Zhen-xing; Shi, Sheng-bing; Han, Fu-li; Wu, Yan-lin; Song, Chun-yan

    2014-09-01

    Laser stealth is an important way of photoelectric stealth weapons systems. According to operational principle of laser range finder, we actively explore and study the stealth performance approval testing technology of laser stealth materials, and bring forward and establish the stealth performance field test methods of stealth efficiency evaluation. Through contrastive test of two kinds of materials, the method is correct and effective.

  8. Alkyl Pyrocarbonate Electrolyte Additives for Performance Enhancement of Li Ion Cells

    NASA Technical Reports Server (NTRS)

    Smart, M. C.; Ratnakumar, B. V.; Surampudi, S.

    2000-01-01

    Lithium ion rechargeable batteries are being developed for various aerospace applications under a NASA-DoD Interagency program. These applications require further improvements in several areas, specifically in the cycle life for LEO and GEO satellites and in the low temperature performance for the Mars Lander and Rover missions. Accordingly, we have been pursuing research studies to achieve improvement in the low temperature performance, long cycle life and active life of Li ion cells. The studies are mainly focused on electrolytes, to identify newer formulations of new electrolyte additives to enhance Li permeability (at low temperatures) and stability towards the electrode. The latter approach is particularly aimed at the formation suitable SEI (solid electrolyte interphase) on carbon electrodes. In this paper, we report the beneficial effect of using alkyl pyrocarbonates as electrolyte additives to improve the low temperature performance of Li ion cells.

  9. Time-Dependent Testing Evaluation and Modeling for Rubber Stopper Seal Performance.

    PubMed

    Zeng, Qingyu; Zhao, Xia

    2018-01-01

    Sufficient rubber stopper sealing performance throughout the entire sealed product life cycle is essential for maintaining container closure integrity in the parenteral packaging industry. However, prior publications have lacked systematic considerations for the time-dependent influence on sealing performance that results from the viscoelastic characteristics of the rubber stoppers. In this paper, we report results of an effort to study these effects by applying both compression stress relaxation testing and residual seal force testing for time-dependent experimental data collection. These experiments were followed by modeling fit calculations based on the Maxwell-Wiechert theory modified with the Kohlrausch-Williams-Watts stretched exponential function, resulting in a nonlinear, time-dependent sealing force model. By employing both testing evaluations and modeling calculations, an in-depth understanding of the time-dependent effects on rubber stopper sealing force was developed. Both testing and modeling data show good consistency, demonstrating that the sealing force decays exponentially over time and eventually levels off because of the viscoelastic nature of the rubber stoppers. The nonlinearity of stress relaxation derives from the viscoelastic characteristics of the rubber stoppers coupled with the large stopper compression deformation into restrained geometry conditions. The modeling fit with capability to handle actual testing data can be employed as a tool to calculate the compression stress relaxation and residual seal force throughout the entire sealed product life cycle. In addition to being time-dependent, stress relaxation is also experimentally shown to be temperature-dependent. The present work provides a new, integrated methodology framework and some fresh insights to the parenteral packaging industry for practically and proactively considering, designing, setting up, controlling, and managing stopper sealing performance throughout the entire

  10. Test anxiety, perfectionism, goal orientation, and academic performance.

    PubMed

    Eum, KoUn; Rice, Kenneth G

    2011-03-01

    Dimensions of perfectionism and goal orientation have been reported to have differential relationships with test anxiety. However, the degree of inter-relationship between different dimensions of perfectionism, the 2 × 2 model of goal orientations proposed by Elliot and McGregor, cognitive test anxiety, and academic performance indicators is not known. Based on data from 134 university students, we conducted correlation and regression analyses to test associations between adaptive and maladaptive perfectionism, four types of goal orientations, cognitive test anxiety, and two indicators of academic performance: proximal cognitive performance on a word list recall test and distal academic performance in terms of grade point average. Cognitive test anxiety was inversely associated with both performance indicators, and positively associated with maladaptive perfectionism and avoidance goal orientations. Adaptive and maladaptive perfectionism accounted for significant variance in cognitive test anxiety after controlling for approach and avoidance goal orientations. Overall, nearly 50% of the variance in cognitive test anxiety could be attributed to gender, goal orientations, and perfectionism. Results suggested that students who are highly test anxious are likely to be women who endorse avoidance goal orientations and are maladaptively perfectionistic.

  11. Web-Based Testing: Exploring the Relationship between Hardware Usability and Test Performance

    ERIC Educational Resources Information Center

    Huff, Kyle; Cline, Melinda; Guynes, Carl S.

    2012-01-01

    Web-based testing has recently become common in both academic and professional settings. A web-based test is administered through a web browser. Individuals may complete a web-based test at nearly any time and at any place. In addition, almost any computer lab can become a testing center. It is important to understand the environmental issues that…

  12. Evaluating Maintenance Performance: Test Administrator's Manual and Test Subject's Instructions for Criterion Referenced Job Task Performance Tests for Electronic Maintenance. Final Report.

    ERIC Educational Resources Information Center

    Shriver, Edgar L.; And Others

    This document furnishes a complete copy of the Test Subject's Instructions and the Test Administrator's Handbook for a battery of criterion referenced Job Task Performance Tests (JTPT) for electronic maintenance. General information is provided on soldering, Radar Set AN/APN-147(v), Radar Set Special Equipment, Radar Set Bench Test Set-Up, and…

  13. EMC system test performance on Spacelab

    NASA Astrophysics Data System (ADS)

    Schwan, F.

    1982-07-01

    Electromagnetic compatibility testing of the Spacelab engineering model is discussed. Documentation, test procedures (including data monitoring and test configuration set up) and performance assessment approach are described. Equipment was assembled into selected representative flight configurations. The physical and functional interfaces between the subsystems were demonstrated within the integration and test sequence which culminated in the flyable configuration Long Module plus one Pallet.

  14. Performance tests of a two phase ejector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harrell, G.S.; Kornhauser, A.A.

    1995-12-31

    The ejector expansion refrigeration cycle is a modified vapor compression cycle in which a two phase ejector is used to recover a portion of the work otherwise lost in the expansion valve. The ejector improves cycle performance by increasing compressor inlet pressure and by lowering the quality of liquid entering the evaporator. Theoretically, a cooling COP improvement of approximately 23% is achievable for a typical refrigerating cycle and an ideal ejector. If the ejector performed as well as typical single phase ejectors an improvement of 12% could be achieved. Previous tests have demonstrated a smaller 3.7% improvement; the difference ismore » in the poor performance of the two phase ejector. The purpose of this research is to understand the operating characteristics of the two phase ejector and to devise design improvements. A two phase ejector test rig has been constructed and tested. Preliminary data show performance superior to previously tested two phase ejectors, but still inferior to single phase ejectors. Ejector performance corresponds to refrigeration cycle COP improvements ranging from 3.9% to 7.6%.« less

  15. 30 CFR 250.449 - What additional BOP testing requirements must I meet?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Blowout Preventer (bop) System Requirements § 250.449 What additional BOP... water to conduct this test. You may use drilling fluids to conduct subsequent tests of a subsea BOP...

  16. 30 CFR 250.449 - What additional BOP testing requirements must I meet?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Blowout Preventer (bop) System Requirements § 250.449 What additional BOP... water to conduct this test. You may use drilling fluids to conduct subsequent tests of a subsea BOP...

  17. 30 CFR 250.449 - What additional BOP testing requirements must I meet?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Blowout Preventer (bop) System Requirements § 250.449 What additional BOP... water to conduct this test. You may use drilling fluids to conduct subsequent tests of a subsea BOP...

  18. Performance of Clinical Laboratories in South African Parasitology Proficiency Testing Surveys between 2004 and 2010

    PubMed Central

    Dini, Leigh; Frean, John

    2012-01-01

    Performance in proficiency testing (PT) schemes is an objective measure of a laboratory's best performance. We examined the performance of participants in two parasitology PT schemes in South Africa from 2004 through 2010. The average rates of acceptable scores over the period were 58% and 66% for the stool and blood parasite schemes, respectively. In our setting, participation in PT alone is insufficient to improve performance; a policy that provides additional resources and training seems necessary. PMID:22814470

  19. Load responsive multilayer insulation performance testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dye, S.; Kopelove, A.; Mills, G. L.

    Cryogenic insulation designed to operate at various pressures from one atmosphere to vacuum, with high thermal performance and light weight, is needed for cryogenically fueled space launch vehicles and aircraft. Multilayer insulation (MLI) performs well in a high vacuum, but the required vacuum shell for use in the atmosphere is heavy. Spray-on foam insulation (SOFI) is often used in these systems because of its light weight, but can have a higher heat flux than desired. We report on the continued development of Load Responsive Multilayer Insulation (LRMLI), an advanced thermal insulation system that uses dynamic beam discrete spacers that providemore » high thermal performance both in atmosphere and vacuum. LRMLI consists of layers of thermal radiation barriers separated and supported by micromolded polymer spacers. The spacers have low thermal conductance, and self-support a thin, lightweight vacuum shell that provides internal high vacuum in the insulation. The dynamic load responsive spacers compress to support the external load of a vacuum shell in one atmosphere, and decompress under reduced atmospheric pressure for lower heat leak. Structural load testing was performed on the spacers with various configurations. LRMLI was installed on a 400 liter tank and boil off testing with liquid nitrogen performed at various chamber pressures from one atmosphere to high vacuum. Testing was also performed with an MLI blanket on the outside of the LRMLI.« less

  20. Load responsive multilayer insulation performance testing

    NASA Astrophysics Data System (ADS)

    Dye, S.; Kopelove, A.; Mills, G. L.

    2014-01-01

    Cryogenic insulation designed to operate at various pressures from one atmosphere to vacuum, with high thermal performance and light weight, is needed for cryogenically fueled space launch vehicles and aircraft. Multilayer insulation (MLI) performs well in a high vacuum, but the required vacuum shell for use in the atmosphere is heavy. Spray-on foam insulation (SOFI) is often used in these systems because of its light weight, but can have a higher heat flux than desired. We report on the continued development of Load Responsive Multilayer Insulation (LRMLI), an advanced thermal insulation system that uses dynamic beam discrete spacers that provide high thermal performance both in atmosphere and vacuum. LRMLI consists of layers of thermal radiation barriers separated and supported by micromolded polymer spacers. The spacers have low thermal conductance, and self-support a thin, lightweight vacuum shell that provides internal high vacuum in the insulation. The dynamic load responsive spacers compress to support the external load of a vacuum shell in one atmosphere, and decompress under reduced atmospheric pressure for lower heat leak. Structural load testing was performed on the spacers with various configurations. LRMLI was installed on a 400 liter tank and boil off testing with liquid nitrogen performed at various chamber pressures from one atmosphere to high vacuum. Testing was also performed with an MLI blanket on the outside of the LRMLI.

  1. Chinese College Test Takers' Individual Differences and Reading Test Performance: A Structural Equation Modeling Approach.

    PubMed

    Zhang, Limei

    2016-06-01

    This study reports on the relationships between test takers' individual differences and their performance on a reading comprehension test. A total of 518 Chinese college students (252 women and 256 men; M age = 19.26 year, SD = 0.98) answered a questionnaire and sit for a reading comprehension test. The study found that test takers' L2 language proficiency was closely linked to their test performance. Test takers' employment of strategies was significantly and positively associated with their performance on the test. Test takers' motivation was found to be significantly associated with reading test performance. Test anxiety was negatively related to their use of reading strategies and test performance. The results of the study lent support to the threshold hypothesis of language proficiency. The implications for classroom teaching were provided. © The Author(s) 2016.

  2. Performance and Life Tests of a Regenerative Blower for EVA Suit Ventilation

    NASA Technical Reports Server (NTRS)

    Izenson, Mike; Chen, Weibo; Paul, Heather L.; Jennings, Mallory A.

    2011-01-01

    Ventilation fans for future space suits must meet demanding performance specifications, satisfy stringent safety requirements for operation in an oxygen atmosphere, and be able to increase output to operate in buddy mode. A regenerative blower is an attractive choice due to its ability to meet these requirements at low operating speed. This paper describes progress in the development and testing of a regenerative blower designed to meet requirements for ventilation subsystems in a future space suit Portable Life Support Systems (PLSS). The blower assembly includes a custom-designed motor that has significantly improved in efficiency during this development effort. The blower was tested at both nominal and buddy mode operating points and head/flow performance and power consumption were measured. The blower was operated for over 1000 hours to demonstrate safe operation in an oxygen test loop at prototypical pressures. In addition, the blower demonstrated operation with the introduction of simulated lunar dust.

  3. 40 CFR 63.1384 - Performance test requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... performance test, the owner or operator must monitor and record the glass pull rate for each glass-melting furnace and, if different, the glass pull rate for each rotary spin manufacturing line and flame attenuation manufacturing line. Record the glass pull rate every 15 minutes during any performance test...

  4. 40 CFR 63.805 - Performance test methods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Performance test methods. 63.805...) National Emission Standards for Wood Furniture Manufacturing Operations § 63.805 Performance test methods. (a)(1) The EPA Method 311 of appendix A of part 63 shall be used in conjunction with formulation data...

  5. Performance test for a solar water heater

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Two reports describe procedures and results of performance tests on domestic solar powered hot water system. Performance tests determine amount of energy collected by system, amount of energy delivered to solar source, power required to operate system and maintain proper tank temperature, overall system efficiency, and temperature distribution in tank.

  6. Beyond relevance and recall: testing new user-centred measures of database performance.

    PubMed

    Stokes, Peter; Foster, Allen; Urquhart, Christine

    2009-09-01

    Measures of the effectiveness of databases have traditionally focused on recall, precision, with some debate on how relevance can be assessed, and by whom. New measures of database performance are required when users are familiar with search engines, and expect full text availability. This research ascertained which of four bibliographic databases (BNI, CINAHL, MEDLINE and EMBASE) could be considered most useful to nursing and midwifery students searching for information for an undergraduate dissertation. Searches on title were performed for dissertation topics supplied by nursing students (n = 9), who made the relevance judgements. Measures of recall and precision were combined with additional factors to provide measures of effectiveness, while efficiency combined measures of novelty and originality and accessibility combined measures for availability and retrievability, based on obtainability. There were significant differences among the databases in precision, originality and availability, but other differences were not significant (Friedman test). Odds ratio tests indicated that BNI, followed by CINAHL were the most effective, CINAHL the most efficient, and BNI the most accessible. The methodology could help library services in purchase decisions as the measure for accessibility, and odds ratio testing helped to differentiate database performance.

  7. Results of tests performed on the Acoustic Quiet Flow Facility Three-Dimensional Model Tunnel: Report on the Modified D.S.M.A. Design

    NASA Technical Reports Server (NTRS)

    Barna, P. S.

    1996-01-01

    Numerous tests were performed on the original Acoustic Quiet Flow Facility Three-Dimensional Model Tunnel, scaled down from the full-scale plans. Results of tests performed on the original scale model tunnel were reported in April 1995, which clearly showed that this model was lacking in performance. Subsequently this scale model was modified to attempt to possibly improve the tunnel performance. The modifications included: (a) redesigned diffuser; (b) addition of a collector; (c) addition of a Nozzle-Diffuser; (d) changes in location of vent-air. Tests performed on the modified tunnel showed a marked improvement in performance amounting to a nominal increase of pressure recovery in the diffuser from 34 percent to 54 percent. Results obtained in the tests have wider application. They may also be applied to other tunnels operating with an open test section not necessarily having similar geometry as the model under consideration.

  8. Performance deterioration due to acceptance testing and flight loads; JT90 jet engine diagnostic program

    NASA Technical Reports Server (NTRS)

    Olsson, W. J.

    1982-01-01

    The results of a flight loads test of the JT9D-7 engine are presented. The goals of this test program were to: measure aerodynamic and inertia loads on the engine during flight, explore the effects of airplane gross weight and typical maneuvers on these flight loads, simultaneously measure the changes in engine running clearances and performance resulting from the maneuvers, make refinements of engine performance deterioration prediction models based on analytical results of the tests, and make recommendations to improve propulsion system performance retention. The test program included a typical production airplane acceptance test plus additional flights and maneuvers to encompass the range of flight loads in revenue service. The test results indicated that aerodynamic loads, primarily at take-off, were the major cause of rub-indicated that aerodynamic loads, primarily at take-off, were the major cause of rub-induced deterioration in the cold sectin of the engine. Differential thermal expansion between rotating and static parts plus aerodynamic loads combined to cause blade-to-seal rubs in the turbine.

  9. The influence of shyness on children's test performance.

    PubMed

    Crozier, W Ray; Hostettler, Kirsten

    2003-09-01

    Research has shown that shy children differ from their peers not only in their use of language in routine social encounters but also in formal assessments of their language development, including psychometric tests of vocabulary. There has been little examination of factors contributing to these individual differences. To investigate cognitive-competence and social anxiety interpretations of differences in children's performance on tests of vocabulary. To examine the performance of shy and less shy children under different conditions of test administration, individually with an examiner or among their peers within the familiar classroom setting. The sample consisted of 240 Year 5 pupils (122 male, 118 female) from 24 primary schools. Shy and less shy children, identified by teacher nomination and checklist ratings, completed vocabulary and mental arithmetic tests in one of three conditions, in a between-subjects design. The conditions varied individual and group administration, and oral and written responses. The conditions of test administration influenced the vocabulary test performance of shy children. They performed significantly more poorly than their peers in the two face-to-face conditions but not in the group test condition. A comparable trend for the arithmetic test was not statistically significant. Across the sample as a whole, shyness correlated significantly with test scores. Shyness does influence children's cognitive test performance and its impact is larger when children are tested face-to-face rather than in a more anonymous group setting. The results are of significance for theories of shyness and have implications for the assessment of schoolchildren.

  10. So ware-Defined Network Solutions for Science Scenarios: Performance Testing Framework and Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Settlemyer, Bradley; Kettimuthu, R.; Boley, Josh

    High-performance scientific work flows utilize supercomputers, scientific instruments, and large storage systems. Their executions require fast setup of a small number of dedicated network connections across the geographically distributed facility sites. We present Software-Defined Network (SDN) solutions consisting of site daemons that use dpctl, Floodlight, ONOS, or OpenDaylight controllers to set up these connections. The development of these SDN solutions could be quite disruptive to the infrastructure, while requiring a close coordination among multiple sites; in addition, the large number of possible controller and device combinations to investigate could make the infrastructure unavailable to regular users for extended periods ofmore » time. In response, we develop a Virtual Science Network Environment (VSNE) using virtual machines, Mininet, and custom scripts that support the development, testing, and evaluation of SDN solutions, without the constraints and expenses of multi-site physical infrastructures; furthermore, the chosen solutions can be directly transferred to production deployments. By complementing VSNE with a physical testbed, we conduct targeted performance tests of various SDN solutions to help choose the best candidates. In addition, we propose a switching response method to assess the setup times and throughput performances of different SDN solutions, and present experimental results that show their advantages and limitations.« less

  11. The Effects of Humor on Test Anxiety and Test Performance

    ERIC Educational Resources Information Center

    Tali, Glenda

    2017-01-01

    Testing in an academic setting provokes anxiety in all students in higher education, particularly nursing students. When students experience high levels of anxiety, the resulting decline in test performance often does not represent an accurate assessment of students' academic achievement. This quantitative, experimental study examined the effects…

  12. Extravehicular Activity Testing in Analog Environments: Evaluating the Effects of Center of Gravity and Environment on Human Performance

    NASA Technical Reports Server (NTRS)

    Gernhardt, M.L.; Chappell, S.P.

    2009-01-01

    The EVA Physiology, Systems and Performance (EPSP) Project is performing tests in different analog environments to understand human performance during Extravehicular Activity (EVA) with the aim of developing more safe and efficient systems for lunar exploration missions and the Constellation Program. The project is characterizing human EVA performance in studies using several test beds, including the underwater NASA Extreme Environment Mission Operations (NEEMO) and Neutral Buoyancy Laboratory (NBL) facilities, JSC fs Partial Gravity Simulator (POGO), and the NASA Reduced Gravity Office (RGO) parabolic flight aircraft. Using these varied testing environments, NASA can gain a more complete understanding of human performance issues related to EVA and the limitations of each testing environment. Tests are focused on identifying and understanding the EVA system factors that affect human performance such as center of gravity (CG), inertial mass, ground reaction forces (GRF), suit weight, and suit pressure. The test results will lead to the development of lunar EVA systems operations concepts and design requirements that optimize human performance and exploration capabilities. METHODS: Tests were conducted in the NBL and during NEEMO missions in the NOAA Aquarius Habitat. A reconfigurable back pack with repositionable mass was used to simulate Perfect, Low, Forward, High, Aft and NASA Baseline CG locations. Subjects performed simulated exploration tasks that included ambulation, kneel and recovery, rock pick-up, and shoveling. Testing using POGO, that simulates partial gravity via pneumatic weight offload system and a similar reconfigurable rig, is underway for a subset of the same tasks. Additionally, test trials are being performed on the RGO parabolic flight aircraft. Subject performance was assessed using a modified Cooper-Harper scale to assess operator compensation required to achieve desired performance. All CG locations are based on the assumption of a

  13. Computed Tomography Inspection and Analysis for Additive Manufacturing Components

    NASA Technical Reports Server (NTRS)

    Beshears, Ronald D.

    2017-01-01

    Computed tomography (CT) inspection was performed on test articles additively manufactured from metallic materials. Metallic AM and machined wrought alloy test articles with programmed flaws and geometric features were inspected using a 2-megavolt linear accelerator based CT system. Performance of CT inspection on identically configured wrought and AM components and programmed flaws was assessed to determine the impact of additive manufacturing on inspectability of objects with complex geometries.

  14. Work zone performance measures pilot test.

    DOT National Transportation Integrated Search

    2011-04-01

    Currently, a well-defined and validated set of metrics to use in monitoring work zone performance do not : exist. This pilot test was conducted to assist state DOTs in identifying what work zone performance : measures can and should be targeted, what...

  15. Test and Evaluation of Ultrasonic Additive Manufacturing (UAM) for a Large Aircraft Maintenance Shelter (LAMS) Baseplate

    DTIC Science & Technology

    2015-03-26

    TEST AND EVALUATION OF ULTRASONIC ADDITIVE MANUFACTURING (UAM) FOR A LARGE AREA MAINTENANCE...States Government. AFIT-ENV-MS-15-M-158 TEST AND EVALUATION OF ULTRASONIC ADDITIVE MANUFACTURING FOR A LARGE AREA MAINTENANCE SHELTER...Civil Engineer (CE) operations. This research replicates a Large Area Maintenance Shelter (LAMS) baseplate design for ultrasonic additive

  16. Improvement of aquaponic performance through micro- and macro-nutrient addition.

    PubMed

    Ru, Dongyun; Liu, Jikai; Hu, Zhen; Zou, Yina; Jiang, Liping; Cheng, Xiaodian; Lv, Zhenting

    2017-07-01

    Aquaponics is one of the "zero waste" industry in the twenty-first century, and is considered to be one of the major trends for the future development of agriculture. However, the low nitrogen utilization efficiency (NUE) restricted its widely application. To date, many attempts have been conducted to improve its NUE. In the present study, effect of micro- and macro-nutrient addition on performance of tilapia-pak choi aquaponics was investigated. Results showed that the addition of micro- and macro-nutrients improved the growth of plant directly and facilitated fish physiology indirectly, which subsequently increased NUE of aquaponics from 40.42 to 50.64%. In addition, remarkable lower total phosphorus concentration was obtained in aquaponics with micro- and macro-nutrient addition, which was attributed to the formation of struvite. Most of the added micro-nutrients were enriched in plant root, while macro-nutrients mainly existed in water. Moreover, no enrichment of micro- and macro-nutrients in aquaponic products (i.e., fish and plant leaves) was observed, indicating that it had no influence on food safety. The findings here reported manifest that appropriate addition of micro- and macro-nutrients to aquaponics is necessary, and would improve its economic feasibility.

  17. SAS molecular tests Salmonella detection kit. Performance tested method 021202.

    PubMed

    Bapanpally, Chandra; Montier, Laura; Khan, Shah; Kasra, Akif; Brunelle, Sharon L

    2014-01-01

    The SAS Molecular tests Salmonella Detection method, a Loop-mediated Isothermal Amplification method, performed as well as or better than the U.S. Department of Agriculture-Food Safety Inspection Service Microbiology Laboratory Guidebook and the U.S. Food and Drug Administration Bacteriological Analytical Manual reference methods for ground beef, beef trim, ground turkey, chicken carcass rinses, bagged mixed lettuce, and fresh spinach. The ground beef (30% fat, 25 g test portion), poultry matrixes and leafy greens were validated in a 6-7 h enrichment, and ground beef (30% fat, 375 g composite test portion) and beef trim (375 g composite test portion) were validated in a 16-20 h enrichment. The method performance for meat and leafy green matrixes was shown to be acceptable under conditions of co-enrichment with Escherichia coli 0157. Thus, after a short 6-7 h co-enrichment step, ground beef, beef trim, lettuce, and spinach can be tested for both Salmonella and E. coli O157. Inclusivity and exclusivity testing revealed no false negatives and no false positives among the 100 Salmonella serovars and 30 non-Salmonella species examined. The method was shown to be robust when enrichment time, DNA extract hold time, and DNA volume were varied.

  18. 49 CFR 173.466 - Additional tests for Type A packagings designed for liquids and gases.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... for liquids and gases. 173.466 Section 173.466 Transportation Other Regulations Relating to...) Materials § 173.466 Additional tests for Type A packagings designed for liquids and gases. (a) In addition to the tests prescribed in § 173.465, Type A packagings designed for liquids and gases must be...

  19. 49 CFR 173.466 - Additional tests for Type A packagings designed for liquids and gases.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... for liquids and gases. 173.466 Section 173.466 Transportation Other Regulations Relating to...) Materials § 173.466 Additional tests for Type A packagings designed for liquids and gases. (a) In addition to the tests prescribed in § 173.465, Type A packagings designed for liquids and gases must be...

  20. 49 CFR 173.466 - Additional tests for Type A packagings designed for liquids and gases.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... for liquids and gases. 173.466 Section 173.466 Transportation Other Regulations Relating to...) Materials § 173.466 Additional tests for Type A packagings designed for liquids and gases. (a) In addition to the tests prescribed in § 173.465, Type A packagings designed for liquids and gases must be...

  1. 49 CFR 173.466 - Additional tests for Type A packagings designed for liquids and gases.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... for liquids and gases. 173.466 Section 173.466 Transportation Other Regulations Relating to...) Materials § 173.466 Additional tests for Type A packagings designed for liquids and gases. (a) In addition to the tests prescribed in § 173.465, Type A packagings designed for liquids and gases must be...

  2. 49 CFR 173.466 - Additional tests for Type A packagings designed for liquids and gases.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... for liquids and gases. 173.466 Section 173.466 Transportation Other Regulations Relating to...) Materials § 173.466 Additional tests for Type A packagings designed for liquids and gases. (a) In addition to the tests prescribed in § 173.465, Type A packagings designed for liquids and gases must be...

  3. 42 CFR 84.103 - Man tests; performance requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Man tests; performance requirements. 84.103 Section...-Contained Breathing Apparatus § 84.103 Man tests; performance requirements. (a) The apparatus shall satisfy... is 24 ±6 °C. (75 ±10 °F.), the maximum temperature of inspired air recorded during man tests shall...

  4. 42 CFR 84.103 - Man tests; performance requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Man tests; performance requirements. 84.103 Section...-Contained Breathing Apparatus § 84.103 Man tests; performance requirements. (a) The apparatus shall satisfy... is 24 ±6 °C. (75 ±10 °F.), the maximum temperature of inspired air recorded during man tests shall...

  5. 42 CFR 84.103 - Man tests; performance requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Man tests; performance requirements. 84.103 Section...-Contained Breathing Apparatus § 84.103 Man tests; performance requirements. (a) The apparatus shall satisfy... is 24 ±6 °C. (75 ±10 °F.), the maximum temperature of inspired air recorded during man tests shall...

  6. Computed Tomography Inspection and Analysis for Additive Manufacturing Components

    NASA Technical Reports Server (NTRS)

    Beshears, Ronald D.

    2016-01-01

    Computed tomography (CT) inspection was performed on test articles additively manufactured from metallic materials. Metallic AM and machined wrought alloy test articles with programmed flaws were inspected using a 2MeV linear accelerator based CT system. Performance of CT inspection on identically configured wrought and AM components and programmed flaws was assessed using standard image analysis techniques to determine the impact of additive manufacturing on inspectability of objects with complex geometries.

  7. 47 CFR 76.601 - Performance tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... television system shall be responsible for insuring that each such system is designed, installed, and... cable television system shall conduct complete performance tests of that system at least twice each... tests shall be directed at determining the extent to which the system complies with all the technical...

  8. Physical performance tests after stroke: reliability and validity.

    PubMed

    Maeda, A; Yuasa, T; Nakamura, K; Higuchi, S; Motohashi, Y

    2000-01-01

    To evaluate the reliability and validity of the modified physical performance tests for stroke survivors who live in a community. The subjects included 40 stroke survivors and 40 apparently healthy independent elderly persons. The physical performance tests for the stroke survivors comprised two physical capacity evaluation tasks that represented physical abilities necessary to perform the main activities of daily living, e.g., standing-up ability (time needed to stand up from bed rest) and walking ability (time needed to walk 10 m). Regarding the reliability of tests, significant correlations were confirmed between test and retest of physical performance tests with both short and long intervals in individuals after stroke. Regarding the validity of tests, the authors studied the significant correlations between the maximum isometric strength of the quardriceps muscle and the time needed to walk 10 m, centimeters reached while sitting and reaching, and the time needed to stand up from bed rest. The authors confirmed that there were significant correlations between the instrumental activity of daily living and the time needed to stand up from bed rest, along with the time needed to walk 10 m for the stroke survivors. These physical performance tests are useful guides for evaluating a level of activity of daily living and physical frailty of stroke survivors living in a community.

  9. The oxidation of organic additives in the positive vanadium electrolyte and its effect on the performance of vanadium redox flow battery

    NASA Astrophysics Data System (ADS)

    Nguyen, Tam D.; Whitehead, Adam; Scherer, Günther G.; Wai, Nyunt; Oo, Moe O.; Bhattarai, Arjun; Chandra, Ghimire P.; Xu, Zhichuan J.

    2016-12-01

    Despite many desirable properties, the vanadium redox flow battery is limited, in the maximum operation temperature that can be continuously endured, before precipitation begins in the positive electrolyte. Many additives have been proposed to improve the thermal stability of the charged positive electrolyte. However, we have found that the apparent stability, revealed in laboratory testing, is often simply an artifact of the test method and arises from the oxidation of the additive, with corresponding partial reduction of V(V) to V(IV). This does not improve the stability of the electrolyte in an operating system. Here, we examined the oxidation of some typical organic additives with carboxyl, alcohol, and multi-functional groups, in sulfuric acid solutions containing V(V). The UV-vis measurements and titration results showed that many compounds reduced the state-of-charge (SOC) of vanadium electrolyte, for example, by 27.8, 88.5, and 81.9% with the addition of 1%wt of EDTA disodium salt, pyrogallol, and ascorbic acid, respectively. The cell cycling also indicated the effect of organic additives on the cell performance, with significant reduction in the usable charge capacity. In addition, a standard screening method for thermally stable additives was introduced, to quickly screen suitable additives for the positive vanadium electrolyte.

  10. Expectancy of an open-book test decreases performance on a delayed closed-book test.

    PubMed

    Agarwal, Pooja K; Roediger, Henry L

    2011-11-01

    Two experiments examined the influence of practice with, and the expectancy of, open-book tests (students viewed studied material while taking the test) versus closed-book tests (students completed the test without viewing the studied material) on delayed retention and transfer. Using GRE materials specifically designed for open-book testing, participants studied passages and then took initial open- or closed-book tests. Open-book testing led to better initial performance than closed-book testing, but on a delayed criterial (closed-book) test both types of testing produced similar retention after a two-day delay in Experiment 1. In Experiment 2 participants were informed in advance about the type of delayed criterial test to expect (open- or closed-book). Expecting an open-book test (relative to a closed-book test) decreased participants' time spent studying and their delayed test performance on closed-book comprehension and transfer tests, demonstrating that test expectancy can influence long-term learning. Expectancy of open-book tests may impair long-term retention and transfer compared to closed-book tests, despite superior initial performance on open-book tests and students' preference for open-book tests.

  11. 46 CFR 160.151-29 - Additional approval tests for SOLAS A and SOLAS B inflatable liferafts.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Resolution A.689(17): (a) Test of filling time for stability appendages. A representative sample of each type... 46 Shipping 6 2011-10-01 2011-10-01 false Additional approval tests for SOLAS A and SOLAS B... Inflatable Liferafts (SOLAS) § 160.151-29 Additional approval tests for SOLAS A and SOLAS B inflatable...

  12. Experimental investigations of the hydrogen addition effects on diesel engine performance

    NASA Astrophysics Data System (ADS)

    Mirica, I.; Pana, C.; Negurescu, N.; Cernat, A.; Nutu, C.

    2016-08-01

    In the global content regarding the impact on the environmental of the gases emissions resulted from the fossil fuels combustion, an interest aspect discussed on the 21st Session of the Conference of the Parties from the 2015 Paris Climate Conference and the gradual diminution of the worldwide oil reserves contribute to the necessity of searching of alternative energy from durable and renewable resources. At the use of hydrogen as addition in air to diesel engine, the level of CO, HC and smoke from the exhaust gases will decrease due to the improvement of the combustion process. At low and medium partial loads and low hydrogen energetic ratios used the NOX emission level can decrease comparative to classic diesel engine. The hydrogen use as fuel for diesel engine leads to the improving of the energetic and emissions performance of the engine due to combustion improvement and reduction of carbon content. The paper presents, in a comparative way, results of the experimental researches carried on a truck compression ignition engine fuelled with diesel fuel and with hydrogen diesel fuel and hydrogen as addition in air at different engine operation regimes. The results obtained during experimental investigations show better energetic and pollution performance of the engine fuelled with hydrogen as addition in air comparative to classic engine. The influences of hydrogen addition on engine operation are shown.

  13. Effect of combinations of additives on the performance of lithium ion batteries

    NASA Astrophysics Data System (ADS)

    Santee, Stuart; Xiao, Ang; Yang, Li; Gnanaraj, Joe; Lucht, Brett L.

    Commercial lithium-ion batteries have excellent performance at room temperature for a few years. However, the calendar life and thermal stability (>50 °C) need to be improved for many applications, including electric vehicles. We have conducted an investigation of the effect of thermal stabilizing additives, including dimethyl acetamide, vinylene carbonate, and lithium bis(oxalato) borate, on the performance of lithium ion batteries stored at 70 °C for one month. The reactions of the lithium hexafluorophosphate/carbonate electrolyte, with and without electrolyte additives, with the surface of the electrodes after initial formation cycling have been analyzed via a combination of IR-ATR and XPS.

  14. Polysulfide and bio-based EP additive performance in vegetable vs. paraffinic base oils

    USDA-ARS?s Scientific Manuscript database

    Twist compression test (TCT) and 4-ball extreme pressure (EP) methods were used to investigate commercial polysulfide (PS) and bio-based polyester (PE) EP additives in paraffinic (150N) and refined soybean (SOY) base oils of similar viscosity. Binary blends of EP additive and base oil were investiga...

  15. Testing for departures from additivity in mixtures of perfluoroalkyl acids (PFAAs)

    EPA Science Inventory

    This study is a follow-up to a paper by Carr, et al. that determined a design structure to optimally test for departures from additivity in a fixed ratio mixture of four perfluoroalkyl acids (PFAAs) using an in vitro transiently-transfected COS- 1 PPARa reporter model with an NHA...

  16. Motivation and Test Anxiety in Test Performance across Three Testing Contexts: The CAEL, CET, and GEPT

    ERIC Educational Resources Information Center

    Cheng, Liying; Klinger, Don; Fox, Janna; Doe, Christine; Jin, Yan; Wu, Jessica

    2014-01-01

    This study examined test-takers' motivation, test anxiety, and test performance across a range of social and educational contexts in three high-stakes language tests: the Canadian Academic English Language (CAEL) Assessment in Canada, the College English Test (CET) in the People's Republic of China, and the General English Proficiency Test (GEPT)…

  17. 49 CFR Appendix A to Part 665 - Tests To Be Performed at the Bus Testing Facility

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Tests To Be Performed at the Bus Testing Facility... Part 665—Tests To Be Performed at the Bus Testing Facility The eight tests to be performed on each vehicle are required by SAFETEA-LU and are based in part on tests described in the FTA report “First...

  18. 49 CFR Appendix A to Part 665 - Tests To Be Performed at the Bus Testing Facility

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Tests To Be Performed at the Bus Testing Facility... Part 665—Tests To Be Performed at the Bus Testing Facility The eight tests to be performed on each vehicle are required by SAFETEA-LU and are based in part on tests described in the FTA report “First...

  19. Improving the Space Surveillance Telescope's Performance Using Multi-Hypothesis Testing

    NASA Astrophysics Data System (ADS)

    Zingarelli, J. Chris; Pearce, Eric; Lambour, Richard; Blake, Travis; Peterson, Curtis J. R.; Cain, Stephen

    2014-05-01

    The Space Surveillance Telescope (SST) is a Defense Advanced Research Projects Agency program designed to detect objects in space like near Earth asteroids and space debris in the geosynchronous Earth orbit (GEO) belt. Binary hypothesis test (BHT) methods have historically been used to facilitate the detection of new objects in space. In this paper a multi-hypothesis detection strategy is introduced to improve the detection performance of SST. In this context, the multi-hypothesis testing (MHT) determines if an unresolvable point source is in either the center, a corner, or a side of a pixel in contrast to BHT, which only tests whether an object is in the pixel or not. The images recorded by SST are undersampled such as to cause aliasing, which degrades the performance of traditional detection schemes. The equations for the MHT are derived in terms of signal-to-noise ratio (S/N), which is computed by subtracting the background light level around the pixel being tested and dividing by the standard deviation of the noise. A new method for determining the local noise statistics that rejects outliers is introduced in combination with the MHT. An experiment using observations of a known GEO satellite are used to demonstrate the improved detection performance of the new algorithm over algorithms previously reported in the literature. The results show a significant improvement in the probability of detection by as much as 50% over existing algorithms. In addition to detection, the S/N results prove to be linearly related to the least-squares estimates of point source irradiance, thus improving photometric accuracy. The views expressed are those of the author and do not reflect the official policy or position of the Department of Defense or the U.S. Government.

  20. 30 CFR 77.102 - Tests for methane; oxygen deficiency; qualified person, additional requirement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tests for methane; oxygen deficiency; qualified... methane; oxygen deficiency; qualified person, additional requirement. Notwithstanding the provisions of § 77.101, on and after December 30, 1971, no person shall be a qualified person for testing for methane...

  1. High School Students' Performance on Vandenberg's Mental Rotations Test: Art Ability, Gender, Activities, Academic Performance, Strategies, and Ease of Taking the Test.

    ERIC Educational Resources Information Center

    Gurny, Helen Graham

    This study tested whether mental rotation performance of 186 high school students (80 males and 106 females) in grades 9 through 12 in art and nonart classes on Vandenbergs Mental Rotations test (S. Vandenberg and Kuse, 1978) was affected by gender, visual-spatial activities, strategies used while performing the test, and the ease of test taking.…

  2. Carbohydrate ingestion improves performance of a new reliable test of soccer performance.

    PubMed

    Currell, Kevin; Conway, Steve; Jeukendrup, Asker E

    2009-02-01

    The aim of the study was to investigate the reliability of a new test of soccer performance and evaluate the effect of carbohydrate (CHO) on soccer performance. Eleven university footballers were recruited and underwent 3 trials in a randomized order. Two of the trials involved ingesting a placebo beverage, and the other, a 7.5% maltodextrin solution. The protocol comprised a series of ten 6-min exercise blocks on an outdoor Astroturf pitch, separated by the performance of 2 of the 4 soccer-specific tests, making the protocol 90 min in duration. The intensity of the exercise was designed to be similar to the typical activity pattern during soccer match play. Participants performed skill tests of dribbling, agility, heading, and shooting throughout the protocol. The coefficients of variation for dribbling, agility, heading, and shooting were 2.2%, 1.2%, 7.0%, and 2.8%, respectively. The mean combined placebo scores were 42.4 +/- 2.7 s, 43.1 +/- 3.7 s, 210 +/- 34 cm, and 212 +/- 17 points for agility, dribbling, heading, and kicking, respectively. CHO ingestion led to a combined agility time of 41.5 +/- 0.8 s, for dribbling 41.7 +/- 3.5 s, 213 +/- 11 cm for heading, and 220 +/- 5 points for kicking accuracy. There was a significant improvement in performance for dribbling, agility, and shooting (p < .05) when CHO was ingested compared with placebo. In conclusion, the protocol is a reliable test of soccer performance, and ingesting CHO leads to an improvement in soccer performance.

  3. 40 CFR 60.723 - Performance tests and compliance provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines § 60.723 Performance tests... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Performance tests and compliance...

  4. 40 CFR 60.723 - Performance tests and compliance provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines § 60.723 Performance tests... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Performance tests and compliance...

  5. MEGARA: large pupil element tests and performance

    NASA Astrophysics Data System (ADS)

    Martínez-Delgado, I.; Sánchez-Blanco, E.; Pérez-Calpena, A.; García-Vargas, M. L.; Maldonado, X. M.; Gil de Paz, A.; Carrasco, E.; Gallego, J.; Iglesias-Páramo, J.; Sánchez-Moreno, F. M.

    2016-07-01

    MEGARA is a third generation spectrograph for the Spanish 10.4m telescope (GTC) providing two observing modes: a large central Integral Field Unit (IFU), called the Large Compact Bundle (LCB), covering a FOV of 12.5 × 11.3 arcsec2, and a Multi-Object Spectrograph (MOS) with a FOV of 3.5 × 3.5 arcmin2. MEGARA will observe the whole visible range from 3650A to 10000A allowing different spectral resolutions (low, medium and high) with R = 6000, 11000 and 18000 respectively. The dispersive elements are placed at the spectrograph pupil position in the path of the collimated beam and they are composed of a set of volume phase hologram gratings (VPHs) sandwiched between two flat windows and coupled in addition to two prisms in the case of the medium- and high-resolution units. We will describe the tests and setups developed to check the requirements of all units, as well as the obtained performance at laboratory

  6. Performance Testing of a Prototypic Annular Linear Induction Pump for Fission Surface Power

    NASA Technical Reports Server (NTRS)

    Polzin, K. A.; Pearson, J. B.; Schoenfeld, M. P.; Webster, K.; Houts, M. G.; Godfroy, T. J.; Bossard, J. A.

    2010-01-01

    Results of performance testing of an annular linear induction pump are presented. The pump electromagnetically pumps liquid metal (NaK) through a circuit specially designed to allow for quantification of the performance. Testing was conducted over a range of conditions, including frequencies of 33, 36, 39, and 60 Hz, liquid metal temperatures from 25 to 525 C, and input voltages from 5 to 120 V. Pump performance spanned a range of flow rates from roughly 0.16 to 5.7 L/s (2.5 to 90 gpm), and pressure head <1 to 90 kPa (<0.145 to 13 psi). The maximum efficiency measured during testing was slightly greater than 6%. The efficiency was fairly insensitive to input frequency from 33 to 39 Hz, and was markedly lower at 60 Hz. In addition, the efficiency decreased as the NaK temperature was raised. While the pump was powered, the fluid responded immediately to changes in the input power level, but when power was removed altogether, there was a brief slow-down period before the fluid would come to rest. The performance of the pump operating on a variable frequency drive providing 60 Hz power compared favorably with the same pump operating on 60 Hz power drawn directly from the electrical grid.

  7. 40 CFR 60.8 - Performance tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... required by the Administrator under section 114 of the Act, the owner or operator of such facility shall conduct performance test(s) and furnish the Administrator a written report of the results of such... Administrator, in writing as soon as practicable following the date the owner or operator first knew, or through...

  8. 40 CFR 60.8 - Performance tests.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... required by the Administrator under section 114 of the Act, the owner or operator of such facility shall conduct performance test(s) and furnish the Administrator a written report of the results of such... Administrator, in writing as soon as practicable following the date the owner or operator first knew, or through...

  9. 40 CFR 60.8 - Performance tests.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... required by the Administrator under section 114 of the Act, the owner or operator of such facility shall conduct performance test(s) and furnish the Administrator a written report of the results of such... Administrator, in writing as soon as practicable following the date the owner or operator first knew, or through...

  10. 40 CFR 60.8 - Performance tests.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... required by the Administrator under section 114 of the Act, the owner or operator of such facility shall conduct performance test(s) and furnish the Administrator a written report of the results of such... Administrator, in writing as soon as practicable following the date the owner or operator first knew, or through...

  11. Supersonic Flight Dynamics Test 1 - Post-Flight Assessment of Simulation Performance

    NASA Technical Reports Server (NTRS)

    Dutta, Soumyo; Bowes, Angela L.; Striepe, Scott A.; Davis, Jody L.; Queen, Eric M.; Blood, Eric M.; Ivanov, Mark C.

    2015-01-01

    NASA's Low Density Supersonic Decelerator (LDSD) project conducted its first Supersonic Flight Dynamics Test (SFDT-1) on June 28, 2014. Program to Optimize Simulated Trajectories II (POST2) was one of the flight dynamics codes used to simulate and predict the flight performance and Monte Carlo analysis was used to characterize the potential flight conditions experienced by the test vehicle. This paper compares the simulation predictions with the reconstructed trajectory of SFDT-1. Additionally, off-nominal conditions seen during flight are modeled in post-flight simulations to find the primary contributors that reconcile the simulation with flight data. The results of these analyses are beneficial for the pre-flight simulation and targeting of the follow-on SFDT flights currently scheduled for summer 2015.

  12. Supra-Additive Interaction of Docosahexaenoic Acid and Naproxen and Gastric Safety on the Formalin Test in Rats.

    PubMed

    Arroyo-Lira, Arlette Guadalupe; Rodríguez-Ramos, Fernando; Ortiz, Mario I; Castañeda-Hernández, Gilberto; Chávez-Piña, Aracely Evangelina

    2017-11-01

    Preclinical Research The aim of this work was to evaluate the effect of docosahexaenoic acid (DHA) on the pharmacokinetics and pharmacodynamics-nociception-of naproxen in rats, as well as to determine the gastric safety resulting from this combination versus naproxen alone. Female Wistar rats were orally administered DHA, naproxen or the DHA-naproxen mixture at fixed-ratio combination of 1:3. The antinociceptive effect was evaluated using the formalin test. The gastric injury was determined 3 h after naproxen administration. An isobolographic analysis was performed to characterize the antinociceptive interaction between DHA and naproxen. To determine the possibility of pharmacokinetic interactions, the oral bioavailability of naproxen was evaluated in presence and absence of oral DHA. The experimental effective dose ED 30 values (Zexp) were decreased from theoretical additive dose values (Zadd; P < 0.05). The isobolographic analysis showed that the combination exhibited supra-additive interaction. The oral administration of DHA increased the pharmacokinetic parameter AUC 0- t of naproxen (P < 0.05). Furthermore, the gastric damage induced by naproxen was abolished when this drug was combined with DHA. These data suggest that oral administration of DHA-naproxen combination induces gastric safety and supra-additive antinociceptive effect in the formalin test so that this combination could be useful to management of inflammatory pain. Drug Dev Res 78 : 332-339, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  13. Performance testing of EVs in the EPRI/TVA EV program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Driggans, R.L.

    1983-01-01

    Performance testing has been completed on four electric vehicles: the Grumman-Olson Kubvan, SCT Electric (VW) Pickup, Jet Industries Electrica, and VW Electrotransporter Bus. The tests performed included vehicle dc energy consumption and driving range at constant speeds and on the SAE J227a C cycle, on-road driving range, hill climbing, maximum acceleration, top speed, and braking performance. Descriptions of the vehicles tested and comparisons of major performance parameters on all four vehicles are presented. This testing was performed at the TVA Electric Vehicle Test Facility.

  14. Uniform Peanut Performance Tests 2012

    USDA-ARS?s Scientific Manuscript database

    The Uniform Peanut Performance Tests (UPPT) were established in 1973 through an informal arrangement among cooperating scientists involving seven major peanut-producing states. In 1995, plant material transfer agreements were also accepted among all cooperators in the UPPT. The year 2012 completed...

  15. Preliminary supersonic flight test evaluation of performance seeking control

    NASA Technical Reports Server (NTRS)

    Orme, John S.; Gilyard, Glenn B.

    1993-01-01

    Digital flight and engine control, powerful onboard computers, and sophisticated controls techniques may improve aircraft performance by maximizing fuel efficiency, maximizing thrust, and extending engine life. An adaptive performance seeking control system for optimizing the quasi-steady state performance of an F-15 aircraft was developed and flight tested. This system has three optimization modes: minimum fuel, maximum thrust, and minimum fan turbine inlet temperature. Tests of the minimum fuel and fan turbine inlet temperature modes were performed at a constant thrust. Supersonic single-engine flight tests of the three modes were conducted using varied after burning power settings. At supersonic conditions, the performance seeking control law optimizes the integrated airframe, inlet, and engine. At subsonic conditions, only the engine is optimized. Supersonic flight tests showed improvements in thrust of 9 percent, increases in fuel savings of 8 percent, and reductions of up to 85 deg R in turbine temperatures for all three modes. The supersonic performance seeking control structure is described and preliminary results of supersonic performance seeking control tests are given. These findings have implications for improving performance of civilian and military aircraft.

  16. Strategies and Performance in Elementary Students' Three-Digit Mental Addition

    ERIC Educational Resources Information Center

    Csíkos, Csaba

    2016-01-01

    The focus of this study is the relationship between students' performance in mental calculation and the strategies they use when solving three-digit mental addition problems. The sample comprises 78 4th grade students (40 boys and 38 girls). Their mean age was 10 years and 4 months. The main novelties of the current research include (1)…

  17. 10 CFR 707.11 - Drugs for which testing is performed.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Drugs for which testing is performed. 707.11 Section 707... Drugs for which testing is performed. Where testing is performed under this part, at a minimum... occurrence testing, the contractor may test for any drug listed in Schedules I or II of the Controlled...

  18. 10 CFR 707.11 - Drugs for which testing is performed.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Drugs for which testing is performed. 707.11 Section 707... Drugs for which testing is performed. Where testing is performed under this part, at a minimum... occurrence testing, the contractor may test for any drug listed in Schedules I or II of the Controlled...

  19. 10 CFR 707.11 - Drugs for which testing is performed.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Drugs for which testing is performed. 707.11 Section 707... Drugs for which testing is performed. Where testing is performed under this part, at a minimum... occurrence testing, the contractor may test for any drug listed in Schedules I or II of the Controlled...

  20. 10 CFR 707.11 - Drugs for which testing is performed.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Drugs for which testing is performed. 707.11 Section 707... Drugs for which testing is performed. Where testing is performed under this part, at a minimum... occurrence testing, the contractor may test for any drug listed in Schedules I or II of the Controlled...

  1. 10 CFR 707.11 - Drugs for which testing is performed.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Drugs for which testing is performed. 707.11 Section 707... Drugs for which testing is performed. Where testing is performed under this part, at a minimum... occurrence testing, the contractor may test for any drug listed in Schedules I or II of the Controlled...

  2. Modification of a compressor performance test bench for liquid slugging observation in refrigeration compressors

    NASA Astrophysics Data System (ADS)

    Ola, Max; Thomas, Christiane; Hesse, Ullrich

    2017-08-01

    Compressor performance test procedures are defined by the standard DIN EN 13771, wherein a variety of possible calorimeter and flow rate measurement methods are suggested. One option is the selection of two independent measurement methods. The accuracies of both selected measurement methods are essential. The second option requires only one method. However the measurement accuracy of the used device has to be verified and recalibrated on a regular basis. The compressor performance test facility at the Technische Universitaet Dresden uses a calibrated flow measurement sensor, a hot gas bypass and a mixed flow heat exchanger. The test bench can easily be modified for tests of various compressor types at different operating ranges and with various refrigerants. In addition, the modified test setup enables the investigation of long term liquid slug and its effects on the compressor. The modification comprises observational components, adjustments of the control system, safety measures and a customized oil recirculation system for compressors which do not contain an integrated oil sump or oil level regulation system. This paper describes the setup of the test bench, its functional principle, the key modifications, first test results and an evaluation of the energy balance.

  3. Effects of addition of different carbon materials on the electrochemical performance of nickel hydroxide electrode

    NASA Astrophysics Data System (ADS)

    Sierczynska, Agnieszka; Lota, Katarzyna; Lota, Grzegorz

    Nickel hydroxide is used as an active material in positive electrodes of rechargeable alkaline batteries. The capacity of nickel-metal hydride (Ni-MH) batteries depends on the specific capacity of the positive electrode and utilization of the active material because of the Ni(OH) 2/NiOOH electrode capacity limitation. The practical capacity of the positive nickel electrode depends on the efficiency of the conductive network connecting the Ni(OH) 2 particle with the current collector. As β-Ni(OH) 2 is a kind of semiconductor, the additives are necessary to improve the conductivity between the active material and the current collector. In this study the effect of adding different carbon materials (flake graphite, multi-walled carbon nanotubes (MWNT)) on the electrochemical performance of pasted nickel-foam electrode was established. A method of production of MWNT special type of catalysts had an influence on the performance of the nickel electrodes. The electrochemical tests showed that the electrode with added MWNT (110-170 nm diameter) exhibited better electrochemical properties in the chargeability, specific discharge capacity, active material utilization, discharge voltage and cycling stability. The nickel electrodes with MWNT addition (110-170 nm diameter) have exhibited a specific capacity close to 280 mAh g -1 of Ni(OH) 2, and the degree of active material utilization was ∼96%.

  4. Fine-motor skills testing and prediction of endovascular performance.

    PubMed

    Bech, Bo; Lönn, Lars; Schroeder, Torben V; Ringsted, Charlotte

    2013-12-01

    Performing endovascular procedures requires good control of fine-motor digital movements and hand-eye coordination. Objective assessment of such skills is difficult. Trainees acquire control of catheter/wire movements at various paces. However, little is known to what extent talent plays for novice candidates at entry to practice. To study the association between performance in a novel aptitude test of fine-motor skills and performance in simulated procedures. The test was based on manual course-tracking using a proprietary hand-operated roller-bar device coupled to a personal computer with monitor view rotation. A total of 40 test repetitions were conducted separately with each hand. Test scores were correlated with simulator performance. Group A (n = 14), clinicians with various levels of endovascular experience, performed a simulated procedure of contralateral iliac artery stenting. Group B (n = 19), medical students, performed 10 repetitions of crossing a challenging aortic bifurcation in a simulator. The test score differed markedly between the individuals in both groups, in particular with the non-dominant hand. Group A: the test score with the non-dominant hand correlated significantly with simulator performance assessed with the global rating scale SAVE (R = -0.69, P = 0.007). There was no association observed from performances with the dominant hand. Group B: there was no significant association between the test score and endovascular skills acquisition neither with the dominant nor with the non-dominant hand. Clinicians with increasing levels of endovascular technical experience had developed good fine-motor control of the non-dominant hand, in particular, that was associated with good procedural performance in the simulator. The aptitude test did not predict endovascular skills acquisition among medical students, thus, cannot be suggested for selection of novice candidates. Procedural experience and practice probably supplant the influence of innate

  5. Herd-of-origin effect on the post-weaning performance of centrally tested Nellore beef cattle.

    PubMed

    de Rezende Neves, Haroldo Henrique; Polin dos Reis, Felipe; Motta Paterno, Flávia; Rocha Guarini, Aline; Carvalheiro, Roberto; da Silva, Lilian Regina; de Oliveira, João Ademir; Aidar de Queiroz, Sandra

    2014-10-01

    The objective of a performance test station is to evaluate the performance of potential breeding bulls earlier in order to decrease the generation interval and increase genetic gain as well. This study evaluates the herd-of-origin influence on end-of-test weight (ETW), average daily weight gain during testing (ADG), average daily weight gain during the adjustment period (ADGadj), rib eye area (REA), marbling (MARB), subcutaneous fat thickness (SFT), conformation (C), early finishing (EF), muscling (M), navel (N) and temperament (T) scores, and scrotal circumference (SC) of Nellore cattle that underwent a performance test. We evaluated 664 animals that participated in the performance tests conducted at the Center for Performance CRV Lagoa between 2007 and 2012. Components of variance for each trait were estimated by an animal model (model 1), using the restricted maximum likelihood method. An alternative animal model (model 2) included, in addition to the fixed effects present in S1, the non-correlated random effect of herd-year (HY). A significant HY effect was observed on ETW, REA, SFT, ADGadj, C, and Cw (p < 0.05). The estimated heritability of all traits decreased when the HY effect was included in the model; also, the bull rank, in deciles, changed significantly for traits ETW, REA, SFT, and C. The adjustment period did not completely remove the environmental effect of herd of origin on ETW, REA, SFT, and C. It is recommended that the herd-of-origin effect should be included in the statistical models used to predict the breeding values of the participants of these performance tests.

  6. Performance on a work-simulating firefighter test versus approved laboratory tests for firefighters and applicants.

    PubMed

    von Heimburg, Erna; Medbø, Jon Ingulf; Sandsund, Mariann; Reinertsen, Randi Eidsmo

    2013-01-01

    Firefighters must meet minimum physical demands. The Norwegian Labour Inspection Authority (NLIA) has approved a standardised treadmill walking test and 3 simple strength tests for smoke divers. The results of the Trondheim test were compared with those of the NLIA tests taking into account possible effects of age, experience level and gender. Four groups of participants took part in the tests: 19 young experienced firefighters, 24 senior male firefighters and inexperienced applicants, 12 male and 8 female. Oxygen uptake (VO2) at exhaustion rose linearly by the duration of the treadmill test. Time spent on the Trondheim test was closely related to performance time and peak VO2 on the treadmill test. Senior experienced firefighters did not perform better than equally fit young applicants. However, female applicants performed poorer on the Trondheim test than on the treadmill test. Performance on the Trondheim test was not closely related to muscle strength beyond a minimum. CONCLUSION. Firefighters completing the Trondheim test in under 19 min fit the requirements of the NLIA treadmill test. The Trondheim test can be used as an alternative to the NLIA tests for testing aerobic fitness but not for muscular strength. Women's result of the Trondheim test were poorer than the results of the NLIA treadmill test, probably because of their lower body mass.

  7. 47 CFR 76.1705 - Performance tests (channels delivered).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Performance tests (channels delivered). 76.1705 Section 76.1705 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Documents to be Maintained for Inspection § 76.1705 Performance tests (channels delivered). The...

  8. 47 CFR 76.1705 - Performance tests (channels delivered).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Performance tests (channels delivered). 76.1705 Section 76.1705 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Documents to be Maintained for Inspection § 76.1705 Performance tests (channels delivered). The...

  9. Influences of deep learning, need for cognition and preparation time on open- and closed-book test performance.

    PubMed

    Heijne-Penninga, Marjolein; Kuks, Jan B M; Hofman, W H Adriaan; Cohen-Schotanus, Janke

    2010-09-01

    The ability to master discipline-specific knowledge is one of the competencies medical students must acquire. In this context, 'mastering' means being able to recall and apply knowledge. A way to assess this competency is to use both open- and closed-book tests. Student performance on both tests can be influenced by the way the student processes information. Deep information processing is expected to influence performance positively. The personal preferences of students in relation to how they process information in general (i.e. their level of need for cognition) may also be of importance. In this study, we examined the inter-relatedness of deep learning, need for cognition and preparation time, and scores on open- and closed-book tests. This study was conducted at the University Medical Centre Groningen. Participants were Year 2 students (n = 423). They were asked to complete a questionnaire on deep information processing, a scale for need for cognition on a questionnaire on intellectualism and, additionally, to write down the time they spent on test preparation. We related these measures to the students' scores on two tests, both consisting of open- and closed-book components and used structural equation modelling to analyse the data. Both questionnaires were completed by 239 students (57%). The results showed that need for cognition positively influenced both open- and closed-book test scores (beta-coefficients 0.05 and 0.11, respectively). Furthermore, study outcomes measured by open-book tests predicted closed-book test results better than the other way around (beta-coefficients 0.72 and 0.11, respectively). Students with a high need for cognition performed better on open- as well as closed-book tests. Deep learning did not influence their performance. Adding open-book tests to the regularly used closed-book tests seems to improve the recall of knowledge that has to be known by heart. Need for cognition may provide a valuable addition to existing theories on

  10. Test techniques for determining laser ranging system performance

    NASA Technical Reports Server (NTRS)

    Zagwodzki, T. W.

    1981-01-01

    Procedures and results of an on going test program intended to evaluate laser ranging system performance levels in the field as well as in the laboratory are summarized. Tests show that laser ranging system design requires consideration of time biases and RMS jitters of individual system components. All simple Q switched lasers tested were found to be inadequate for 10 centimeter ranging systems. Timing discriminators operating over a typical 100:1 dynamic signal range may introduce as much as 7 to 9 centimeters of range bias. Time interval units commercially available today are capable of half centimeter performance and are adequate for all field systems currently deployed. Photomultipliers tested show typical tube time biases of one centimeter with single photoelectron transit time jitter of approximately 10 centimeters. Test results demonstrate that NASA's Mobile Laser Ranging System (MOBLAS) receiver configuration is limiting system performance below the 100 photoelectron level.

  11. Exploration of task performance tests in a physics laboratory

    NASA Astrophysics Data System (ADS)

    Liu, Dan; El Turkey, Houssein

    2017-11-01

    In this article, we investigate the implementation of task performance tests in an undergraduate physics laboratory. Two performance tests were carried out over two semesters using the task of building a DC circuit. The first implementation in Spring 2014 had certain concerns such as the privacy of students’ testing and their ‘trial and error’ attempts. These concerns were addressed in Fall 2015 through implementing a second performance test. The second implementation was administered differently but the content of the two tests was the same. We discuss the validity of both implementations and present the correlation (or lack of) between the time that students needed to complete the tests and their grades from a paper-based laboratory assessment method.

  12. A Fully Non-Metallic Gas Turbine Engine Enabled by Additive Manufacturing Part I: System Analysis, Component Identification, Additive Manufacturing, and Testing of Polymer Composites

    NASA Technical Reports Server (NTRS)

    Grady, Joseph E.; Haller, William J.; Poinsatte, Philip E.; Halbig, Michael C.; Schnulo, Sydney L.; Singh, Mrityunjay; Weir, Don; Wali, Natalie; Vinup, Michael; Jones, Michael G.; hide

    2015-01-01

    The research and development activities reported in this publication were carried out under NASA Aeronautics Research Institute (NARI) funded project entitled "A Fully Nonmetallic Gas Turbine Engine Enabled by Additive Manufacturing." The objective of the project was to conduct evaluation of emerging materials and manufacturing technologies that will enable fully nonmetallic gas turbine engines. The results of the activities are described in three part report. The first part of the report contains the data and analysis of engine system trade studies, which were carried out to estimate reduction in engine emissions and fuel burn enabled due to advanced materials and manufacturing processes. A number of key engine components were identified in which advanced materials and additive manufacturing processes would provide the most significant benefits to engine operation. The technical scope of activities included an assessment of the feasibility of using additive manufacturing technologies to fabricate gas turbine engine components from polymer and ceramic matrix composites, which were accomplished by fabricating prototype engine components and testing them in simulated engine operating conditions. The manufacturing process parameters were developed and optimized for polymer and ceramic composites (described in detail in the second and third part of the report). A number of prototype components (inlet guide vane (IGV), acoustic liners, engine access door) were additively manufactured using high temperature polymer materials. Ceramic matrix composite components included turbine nozzle components. In addition, IGVs and acoustic liners were tested in simulated engine conditions in test rigs. The test results are reported and discussed in detail.

  13. Improving the space surveillance telescope's performance using multi-hypothesis testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chris Zingarelli, J.; Cain, Stephen; Pearce, Eric

    2014-05-01

    The Space Surveillance Telescope (SST) is a Defense Advanced Research Projects Agency program designed to detect objects in space like near Earth asteroids and space debris in the geosynchronous Earth orbit (GEO) belt. Binary hypothesis test (BHT) methods have historically been used to facilitate the detection of new objects in space. In this paper a multi-hypothesis detection strategy is introduced to improve the detection performance of SST. In this context, the multi-hypothesis testing (MHT) determines if an unresolvable point source is in either the center, a corner, or a side of a pixel in contrast to BHT, which only testsmore » whether an object is in the pixel or not. The images recorded by SST are undersampled such as to cause aliasing, which degrades the performance of traditional detection schemes. The equations for the MHT are derived in terms of signal-to-noise ratio (S/N), which is computed by subtracting the background light level around the pixel being tested and dividing by the standard deviation of the noise. A new method for determining the local noise statistics that rejects outliers is introduced in combination with the MHT. An experiment using observations of a known GEO satellite are used to demonstrate the improved detection performance of the new algorithm over algorithms previously reported in the literature. The results show a significant improvement in the probability of detection by as much as 50% over existing algorithms. In addition to detection, the S/N results prove to be linearly related to the least-squares estimates of point source irradiance, thus improving photometric accuracy.« less

  14. Performance evaluation of Space Shuttle SRB parachutes from air drop and scaled model wind tunnel tests. [Solid Rocket Booster recovery system

    NASA Technical Reports Server (NTRS)

    Moog, R. D.; Bacchus, D. L.; Utreja, L. R.

    1979-01-01

    The aerodynamic performance characteristics have been determined for the Space Shuttle Solid Rocket Booster drogue, main, and pilot parachutes. The performance evaluation on the 20-degree conical ribbon parachutes is based primarily on air drop tests of full scale prototype parachutes. In addition, parametric wind tunnel tests were performed and used in parachute configuration development and preliminary performance assessments. The wind tunnel test data are compared to the drop test results and both sets of data are used to determine the predicted performance of the Solid Rocket Booster flight parachutes. Data from other drop tests of large ribbon parachutes are also compared with the Solid Rocket Booster parachute performance characteristics. Parameters assessed include full open terminal drag coefficients, reefed drag area, opening characteristics, clustering effects, and forebody interference.

  15. The Influence of Testing Prompt and Condition on Middle School Students’ Retell Performance

    PubMed Central

    Reed, Deborah K.; Petscher, Yaacov

    2015-01-01

    This study examined whether the type of prompt or the method of passage reading had an effect on the retell performance of 6th–8th graders randomly assigned to one of four retell testing conditions. Both the type of prompt and the use of follow-up prompting were significantly related to the percentage of predetermined idea units retold. Effect sizes were approximately moderate (d = .44–.62) when one change was made to the prompt but were strong (d = .96–1.05) with a combination of changes. The addition of silent reading did not significantly improve performance. PMID:26366034

  16. Relationships of physical performance tests to military-relevant tasks in women.

    PubMed

    Szivak, Tunde K; Kraemer, William J; Nindl, Bradley C; Gotshalk, Lincoln A; Volek, Jeff S; Gomez, Ana L; Dunn-Lewis, Courtenay; Looney, David P; Comstock, Brett A; Hooper, David R; Flanagan, Shawn D; Maresh, Carl M

    2014-01-01

    This investigation sought to determine the most predictive measures of performance on a repetitive box lifting task (RBLT) and load bearing task (LBT) among 123 women (aged ±4 years, height 165±7 cm, body mass 64±10 kg). To determine the relationship of various predictors to performance on the RBLT and LBT, multiple regression analysis was conducted on body mass, height, leg cross-sectional area, upper and lower body muscular strength, lower body explosive power, upper and lower body local muscular endurance, and aerobic capacity. The mean±SD (range) number of repetitions for the RBLT was 86±23 (20-159). The mean±SD (range) time to complete the LBT was 2,054±340 seconds (1,307-3,447). The following equations were generated: RBLT (number of repetitions)=57.4+0.2(peak jump power)+0.4(number of pushups in 2 minutes)+0.15(number of repetitions during the squat endurance test)+1.39(one repetition maximal strength boxlift (kg))-0.04(2-mile run time (2MR) in seconds), R=0.81; standard error of the estimate (SEE)=14; LBT (in seconds)=1,831-4.28(number of repetitions during the squat endurance test)+0.95(2MR in seconds)-13.4(body mass), R=0.73; SEE=232. We found that the 2MR and squat endurance test were significant predictive factors for performance on both load carriage tasks. These data also imply that women's performance in combat-related tasks can be improved with training that targets muscular strength, power, and local muscular endurance in addition to aerobic capacity.

  17. Test performance of immunologic fecal occult blood testing and sigmoidoscopy compared with primary colonoscopy screening for colorectal advanced adenomas.

    PubMed

    Khalid-de Bakker, Carolina A J; Jonkers, Daisy M A E; Sanduleanu, Silvia; de Bruïne, Adriaan P; Meijer, Gerrit A; Janssen, Jan B M J; van Engeland, Manon; Stockbrügger, Reinhold W; Masclee, Ad A M

    2011-10-01

    Given the current increase in colorectal cancer screening, information on performance of screening tests is needed, especially in groups with a presumed lower test performance. We compared test performance of immunologic fecal occult blood testing (FIT) and pseudosigmoidoscopy with colonoscopy for detection of advanced adenomas in an average risk screening population. In addition, we explored the influence of gender, age, and location on test performance. FIT was collected prior to colonoscopy with a 50 ng/mL cutoff point. FIT results and complete colonoscopy findings were available from 329 subjects (mean age: 54.6 ± 3.7 years, 58.4% women). Advanced adenomas were detected in 38 (11.6%) of 329 subjects. Sensitivity for advanced adenomas of FIT and sigmoidoscopy were 15.8% (95% CI: 6.0-31.3) and 73.7% (95% CI: 56.9-86.6), respectively. No sensitivity improvement was obtained using the combination of sigmoidoscopy and FIT. Mean fecal hemoglobin in FIT positives was significantly lower for participants with only proximal adenomas versus those with distal ones (P = 0.008), for women versus men (P = 0.023), and for younger (<55 years) versus older (≥55 years) subjects (P = 0.029). Sensitivities of FIT were 0.0% (95% CI: 0.0-30.9) in subjects with only proximal versus 21.4% (95% CI: 8.3-41.0) in those with distal nonadvanced adenomas; 5.3% (95% CI: 0.0-26.0) in women versus 26.3% (95% CI: 9.2-51.2) in men; 9.5% (95% CI: 1.2-30.4) in younger versus 23.5% (95% CI: 6.8-49.9) in older subjects. Sigmoidoscopy had a significantly higher sensitivity for advanced adenomas than FIT. A single FIT showed very low sensitivity, especially in subjects with only proximal nonadvanced adenomas, in women, and in younger subjects. This points to the existence of "low" FIT performance in subgroups and the need for more tailored screening strategies.

  18. Test plan for performance testing of the Eaton AC-3 electric vehicle

    NASA Astrophysics Data System (ADS)

    Crumley, R.; Heiselmann, H. W.

    1985-04-01

    An alternating current (ac) propulsion system for an electric vehicle was developed and tested. The test bed vehicle is a modified 1981 Mercury Lynx. The test plan was prepared specifically for the third modification to this test bed and identified as the Eaton AC-3. The scope of the testing done on the Eaton AC-3 includes coastdown and dynamometer tests but does not include environmental, on-road, or track testing. Coastdown testing is performed in accordance with SAE J-1263 (SAE Recommended Practice for Road Load Measurement and Dynamometer Simulation Using Coastdown Techniques).

  19. The calibration and flight test performance of the space shuttle orbiter air data system

    NASA Technical Reports Server (NTRS)

    Dean, A. S.; Mena, A. L.

    1983-01-01

    The Space Shuttle air data system (ADS) is used by the guidance, navigation and control system (GN&C) to guide the vehicle to a safe landing. In addition, postflight aerodynamic analysis requires a precise knowledge of flight conditions. Since the orbiter is essentially an unpowered vehicle, the conventional methods of obtaining the ADS calibration were not available; therefore, the calibration was derived using a unique and extensive wind tunnel test program. This test program included subsonic tests with a 0.36-scale orbiter model, transonic and supersonic tests with a smaller 0.2-scale model, and numerous ADS probe-alone tests. The wind tunnel calibration was further refined with subsonic results from the approach and landing test (ALT) program, thus producing the ADS calibration for the orbital flight test (OFT) program. The calibration of the Space Shuttle ADS and its performance during flight are discussed in this paper. A brief description of the system is followed by a discussion of the calibration methodology, and then by a review of the wind tunnel and flight test programs. Finally, the flight results are presented, including an evaluation of the system performance for on-board systems use and a description of the calibration refinements developed to provide the best possible air data for postflight analysis work.

  20. Additive effects of beta-alanine and sodium bicarbonate on upper-body intermittent performance.

    PubMed

    Tobias, Gabriel; Benatti, Fabiana Braga; de Salles Painelli, Vitor; Roschel, Hamilton; Gualano, Bruno; Sale, Craig; Harris, Roger C; Lancha, Antonio Herbert; Artioli, Guilherme Gianinni

    2013-08-01

    We examined the isolated and combined effects of beta-alanine (BA) and sodium bicarbonate (SB) on high-intensity intermittent upper-body performance in judo and jiu-jitsu competitors. 37 athletes were assigned to one of four groups: (1) placebo (PL)+PL; (2) BA+PL; (3) PL+SB or (4) BA+SB. BA or dextrose (placebo) (6.4 g day⁻¹) was ingested for 4 weeks and 500 mg kg⁻¹ BM of SB or calcium carbonate (placebo) was ingested for 7 days during the 4th week. Before and after 4 weeks of supplementation, the athletes completed four 30-s upper-body Wingate tests, separated by 3 min. Blood lactate was determined at rest, immediately after and 5 min after the 4th exercise bout, with perceived exertion reported immediately after the 4th bout. BA and SB alone increased the total work done in +7 and 8 %, respectively. The co-ingestion resulted in an additive effect (+14 %, p < 0.05 vs. BA and SB alone). BA alone significantly improved mean power in the 2nd and 3rd bouts and tended to improve the 4th bout. SB alone significantly improved mean power in the 4th bout and tended to improve in the 2nd and 3rd bouts. BA+SB enhanced mean power in all four bouts. PL+PL did not elicit any alteration on mean and peak power. Post-exercise blood lactate increased with all treatments except with PL+PL. Only BA+SB resulted in lower ratings of perceived exertion (p = 0.05). Chronic BA and SB supplementation alone equally enhanced high-intensity intermittent upper-body performance in well-trained athletes. Combined BA and SB promoted a clear additive ergogenic effect.

  1. Motivational deficits and cognitive test performance in schizophrenia.

    PubMed

    Fervaha, Gagan; Zakzanis, Konstantine K; Foussias, George; Graff-Guerrero, Ariel; Agid, Ofer; Remington, Gary

    2014-09-01

    Motivational and cognitive deficits are core features of schizophrenia, both closely linked with functional outcomes. Although poor effort and decreased motivation are known to affect performance on cognitive tests, the extent of this relationship is unclear in patients with schizophrenia. To evaluate the association between intrinsic motivation and cognitive test performance in patients with schizophrenia. Cross-sectional and 6-month prospective follow-up study performed at 57 sites in the United States, including academic and community medical treatment centers, participating in the Clinical Antipsychotic Trials of Intervention Effectiveness study. The primary sample included 431 stable patients with a DSM-IV diagnosis of schizophrenia currently receiving a stable medication regimen. Cognitive performance and intrinsic motivation were evaluated using a comprehensive neuropsychological test battery and a derived measure from the Heinrichs-Carpenter Quality of Life Scale, respectively. Symptom severity and functional status were also assessed. The primary outcome variable was global neurocognition. Individual domains of cognition were also evaluated for their association with motivation. Level of intrinsic motivation was significantly and positively correlated with global cognitive test performance, a relationship that held for each domain of cognition evaluated (correlation range, 0.20-0.34; P < .001). This association was found to be reliable after statistically accounting for positive, negative, depressive, and overall symptom severity (P < .05) and after accounting for community functioning (P < .001). The relationship between motivation and cognitive performance also remained significant after controlling for antipsychotic dose (P < .05). Prospective increase in motivation during the 6-month follow-up was also found to be significantly related to improvement in global cognitive performance (P < .05). The present findings provide strong

  2. Does increased effort compensate for performance debilitating test anxiety?

    PubMed

    Putwain, David W; Symes, Wendy

    2018-05-24

    It is well established that test anxiety is negatively related to examination performance. Based on attentional control theory, the aim of this study was to examine whether increased effort can protect against performance debilitating test anxiety. Four hundred and sixty-six participants (male = 228; 48.9%; White = 346, 74.3%; mean age = 15.7 years) completed self-report measures of test anxiety and effort that were matched to performance on a high-stakes secondary school examination. The worry and bodily symptoms components of test anxiety were negatively, and effort, positively related to examination performance. Effort moderated the negative relation between bodily symptoms and examination performance. At low effort, the negative relationship was amplified and at high effort was attenuated. Compensatory effort protects performance against bodily symptoms but not worry. It is possible that the cognitive load on working memory arising from the combination of worry and examination demands may be too high to be compensated by effort. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  3. Engine performance and exhaust emission analysis of a single cylinder diesel engine fuelled with water-diesel emulsion fuel blended with manganese metal additives

    NASA Astrophysics Data System (ADS)

    Muhsin Ithnin, Ahmad; Jazair Yahya, Wira; Baun Fletcher, Jasmine; Kadir, Hasannuddin Abd

    2017-10-01

    Water-in-diesel emulsion fuel (W/D) is one of the alternative fuels that capable to reduce the exhaust emission of diesel engine significantly especially the nitrogen oxides (NOx) and particulate matter (PM). However, the usage of W/D emulsion fuels contributed to higher CO emissions. Supplementing metal additive into the fuel is the alternate way to reduce the CO emissions and improve performance. The present paper investigates the effect of using W/D blended with organic based manganese metal additives on the diesel engine performance and exhaust emission. The test were carried out by preparing and analysing the results observed from five different tested fuel which were D2, emulsion fuel (E10: 89% D2, 10% - water, 1% - surfactant), E10Mn100, E10Mn150, E10Mn200. Organic based Manganese (100ppm, 150ppm, 200ppm) used as the additive in the three samples of the experiments. E10Mn200 achieved the maximum reduction of BSFC up to 13.66% and has the highest exhaust gas temperature. Whereas, E10Mn150 achieved the highest reduction of CO by 14.67%, and slightly increased of NOx emissions as compared to other emulsion fuels. Organic based manganese which act as catalyst promotes improvement of the emulsion fuel performance and reduced the harmful emissions discharged.

  4. The use of hydrated lime as an antistripping additive : final report.

    DOT National Transportation Integrated Search

    1987-01-01

    The purpose of this investigation was to evaluate the performance of six test sections of asphalt concrete that contained no additive, hydrated lime, and a chemical additive. Tests were also conducted on pavement samples taken periodically to determi...

  5. Active matrix organic light emitting diode (AMOLED) performance and life test results

    NASA Astrophysics Data System (ADS)

    Fellowes, David A.; Wood, Michael V.; Hastings, Arthur R., Jr.; Draper, Russell S.; Lum, Alden K.; Ghosh, Amalkumar P.; Prache, Olivier; Wacyk, Ihor

    2010-04-01

    The US Army and eMagin Corporation established a Cooperative Research and Development Agreement (CRADA) to characterize the ongoing improvements in the lifetime of OLED displays. This CRADA also called for the evaluation of OLED performance as the need arises, especially when new products are developed or when a previously untested parameter needs to be understood. In 2006, eMagin Corporation developed long-life OLED-XLTM devices for use in their AMOLED microdisplays for head-worn applications. Through Research and Development programs from 2007 to 2009 with the US Government, eMagin made additional improvements in OLED life and developed the first SXGA (1280 × 1024 triad pixels) OLED microdisplay. US Army RDECOM CERDEC NVESD conducted life and performance tests on these displays, publishing results at the 2007, 2008, and 2009 SPIE Defense and Security Symposia1,2,3. Life and performance tests have continued through 2009, and this data will be presented along with a recap of previous data. This should result in a better understanding of the applicability of AMOLEDs in military and commercial head mounted systems: where good fits are made, and where further development might be desirable.

  6. Active matrix organic light-emitting diode (AMOLED) performance and life test results

    NASA Astrophysics Data System (ADS)

    Fellowes, David A.; Wood, Michael V.; Hastings, Arthur R., Jr.; Draper, Russell S.; Ghosh, Amalkumar; Prache, Olivier; Wacyk, Ihor; Ali, Tariq; Khayrullin, Ilyas

    2011-06-01

    The US Army and eMagin Corporation established a Cooperative Research and Development Agreement (CRADA) to characterize the ongoing improvements in the lifetime of OLED displays. This CRADA also called for the evaluation of OLED performance as the need arises, especially when new products are developed or when a previously untested parameter needs to be understood. In 2006, eMagin Corporation developed long-life OLED-XL devices for use in their AMOLED microdisplays for head-worn applications. Through research and development programs from 2007 to 2010 with the US Government, eMagin made additional improvements in OLED life and developed the first SXGA (1280 X 1024 triad pixels) OLED microdisplay. US Army RDECOM CERDEC NVESD conducted life and performance tests on these displays, publishing results at the 2007, 2008, 2009, and 2010 SPIE Defense and Security Symposia1,2,3,4. Life and performance tests have continued through 2010, and this data will be presented along with a recap of previous data. This should result in a better understanding of the applicability of AMOLEDs in military and commercial head mounted systems: where good fits are made, and where further development might be desirable.

  7. NCAT test track design, construction, and performance

    DOT National Transportation Integrated Search

    2002-11-01

    Empirical laboratory tests have been used for years to test hot mix asphalt (HMA) to determine the potential for various mixtures to perform well. As the amount of traffic has increased (higher volumes, higher loads, and increased tire pressures) the...

  8. Enhanced Large Solid Rocket Motor Understanding Through Performance Margin Testing: RSRM Five-Segment Engineering Test Motor (ETM-3)

    NASA Technical Reports Server (NTRS)

    Huppi, Hal; Tobias, Mark; Seiler, James

    2003-01-01

    The Five-Segment Engineering Test Motor (ETM-3) is an extended length reusable solid rocket motor (RSRM) intended to increase motor performance and internal environments above the current four-segment RSRM flight motor. The principal purpose of ETM-3 is to provide a test article for RSRM component margin testing. As the RSRM and Space Shuttle in general continue to age, replacing obsolete materials becomes an ever-increasing issue. Having a five-segment motor that provides environments in excess of normal opera- tion allows a mechanism to subject replacement materials to a more severe environment than experienced in flight. Additionally, ETM-3 offers a second design data point from which to develop and/or validate analytical models that currently have some level of empiricism associated with them. These enhanced models have the potential to further the understanding of RSRM motor performance and solid rocket motor (SRM) propulsion in general. Furthermore, these data could be leveraged to support a five-segment booster (FSB) development program should the Space Shuttle program choose to pursue this option for abort mode enhancements during the ascent phase. A tertiary goal of ETM-3 is to challenge both the ATK Thiokol Propulsion and NASA MSFC technical personnel through the design and analysis of a large solid rocket motor without the benefit of a well-established performance database such as the RSRM. The end result of this undertaking will be a more competent and experienced workforce for both organizations. Of particular interest are the motor design characteristics and the systems engineering approach used to conduct a complex yet successful large motor static test. These aspects of ETM-3 and more will be summarized.

  9. Development of a grinding-specific performance test set-up.

    PubMed

    Olesen, C G; Larsen, B H; Andresen, E L; de Zee, M

    2015-01-01

    The aim of this study was to develop a performance test set-up for America's Cup grinders. The test set-up had to mimic the on-boat grinding activity and be capable of collecting data for analysis and evaluation of grinding performance. This study included a literature-based analysis of grinding demands and a test protocol developed to accommodate the necessary physiological loads. This study resulted in a test protocol consisting of 10 intervals of 20 revolutions each interspersed with active resting periods of 50 s. The 20 revolutions are a combination of both forward and backward grinding and an exponentially rising resistance. A custom-made grinding ergometer was developed with computer-controlled resistance and capable of collecting data during the test. The data collected can be used to find measures of grinding performance such as peak power, time to complete and the decline in repeated grinding performance.

  10. Performance of School Age Reading Disabled Students on the Phonological Awareness Subtests of the Comprehensive Test of Phonological Processing (CTOPP)

    ERIC Educational Resources Information Center

    Marshall, Dorothy; Christo, Catherine; Davis, John

    2013-01-01

    This study examined the performance of reading disabled children on the two Phonological Awareness Subtests of the Comprehensive Test of Phonological Processing (CTOPP). Participants performed significantly different on these two subtests with a poorer performance on the Elision subtest than Blending Words. In addition, the two subtests were not…

  11. Lessons Learned from Performance Testing of Humans in Spacesuits in Simulated Reduced Gravity

    NASA Technical Reports Server (NTRS)

    Norcross, Jason R.; Chappell, Steven P.; Gernhardt, Michael L.

    2010-01-01

    . When this is coupled with the volumetric constraints of the plane, both task selection and data collection options are significantly limited. The underwater environments also allow all 6 DOF and allow off-loading to be applied throughout the body, but the data collection capabilities are limited to little more than subjective ratings. In addition, water drag negatively affects performance of tasks requiring dynamic motion. Field analogs provide the ability to simulate lunar terrain and more realistic mission-like objectives, but all of them operate at 1-g, so suited human performance testing generally must utilize a reduced-mass or "mockup" suit, depending on study objectives. In general, the ground-based overhead-suspension partial-gravity analogs like POGO allow the most diverse data collection methods possible while still simulating partial gravity. However, as currently designed, the POGO has significant limitations. Design of the Active Response Gravity Offload System (ARGOS) has begun and is focusing on adding full x,y,z translational DOF, improved offload accuracy, increased lift capacity, and active control of the x and y axes to minimize offload system inertia. Additionally, a new gimbal is being designed to reduce mass and inertia and to be able to work with different suits, as the current gimbal only supports suited testing with the Mark III Technology Demonstrator Suit (MKIII).

  12. The DOE ETV-1 Electric Test Vehicle. Phase 3: Performance Testing and system evaluation

    NASA Technical Reports Server (NTRS)

    Kurtz, D.

    1981-01-01

    Engineering tests were conducted in order to characterize overall system performance and component efficiencies within the system environment. A dynamometer was used in order to minimize the ambient effects and large uncertainties present in track testing. Extensive test requirements were defined and procedures were carefully controlled in order to maintain a high degree of credibility. Limited track testing was performed in order to corroborate the dynamometer results. Test results include an energy flow analysis through the major subsystems and incorporate the aerodynamic and rolling losses under cyclic and various steady speed conditions. The major output from all relevant dynamometer and track tests is also included.

  13. Cholera Rapid Test with Enrichment Step Has Diagnostic Performance Equivalent to Culture

    PubMed Central

    Ontweka, Lameck N.; Deng, Lul O.; Rauzier, Jean; Debes, Amanda K.; Tadesse, Fisseha; Parker, Lucy A.; Wamala, Joseph F.; Bior, Bior K.; Lasuba, Michael; But, Abiem Bona; Grandesso, Francesco; Jamet, Christine; Cohuet, Sandra; Ciglenecki, Iza; Serafini, Micaela; Sack, David A.; Quilici, Marie-Laure; Azman, Andrew S.; Luquero, Francisco J.

    2016-01-01

    Cholera rapid diagnostic tests (RDT) could play a central role in outbreak detection and surveillance in low-resource settings, but their modest performance has hindered their broad adoption. The addition of an enrichment step may improve test specificity. We describe the results of a prospective diagnostic evaluation of the Crystal VC RDT (Span Diagnostics, India) with enrichment step and of culture, each compared to polymerase chain reaction (PCR), during a cholera outbreak in South Sudan. RDTs were performed on alkaline peptone water inoculated with stool and incubated for 4–6 hours at ambient temperature. Cholera culture was performed from wet filter paper inoculated with stool. Molecular detection of Vibrio cholerae O1 by PCR was done from dry Whatman 903 filter papers inoculated with stool, and from wet filter paper supernatant. In August and September 2015, 101 consecutive suspected cholera cases were enrolled, of which 36 were confirmed by PCR. The enriched RDT had 86.1% (95% CI: 70.5–95.3) sensitivity and 100% (95% CI: 94.4–100) specificity compared to PCR as the reference standard. The sensitivity of culture versus PCR was 83.3% (95% CI: 67.2–93.6) for culture performed on site and 72.2% (95% CI: 54.8–85.8) at the international reference laboratory, where samples were tested after an average delay of two months after sample collection, and specificity was 98.5% (95% CI: 91.7–100) and 100% (95% CI: 94.5–100), respectively. The RDT with enrichment showed performance comparable to that of culture and could be a sustainable alternative to culture confirmation where laboratory capacity is limited. PMID:27992488

  14. Testing and performance analysis of a 650 Mbps QPPM modem for free-space laser communications

    NASA Astrophysics Data System (ADS)

    Mortensen, Dale J.

    1994-08-01

    The testing and performance of a prototype modem developed at NASA Lewis Research Center for high-speed free-space direct detection optical communications is described. The testing was performed under laboratory conditions using computer control with specially developed test equipment that simulates free-space link conditions. The modem employs quaternary pulse position modulation (QPPM) at 325 Megabits per second (Mbps) on two optical channels, which are multiplexed to transmit a single 650 Mbps data stream. The measured results indicate that the receiver's automatic gain control (AGC), phased-locked-loop slot clock recovery, digital symbol clock recovery, matched filtering, and maximum likelihood data recovery circuits were found to have only 1.5 dB combined implementation loss during bit-error-rate (BER) performance measurements. Pseudo random bit sequences and real-time high quality video sources were used to supply 650 Mbps and 325 Mbps data streams to the modem. Additional testing revealed that Doppler frequency shifting can be easily tracked by the receiver, that simulated pointing errors are readily compensated for by the AGC circuits, and that channel timing skew affects the BER performance in an expected manner. Overall, the needed technologies for a high-speed laser communications modem were demonstrated.

  15. Evaluation of the Thermo Scientific SureTect Listeria species assay. AOAC Performance Tested Method 071304.

    PubMed

    Cloke, Jonathan; Evans, Katharine; Crabtree, David; Hughes, Annette; Simpson, Helen; Holopainen, Jani; Wickstrand, Nina; Kauppinen, Mikko; Leon-Velarde, Carlos; Larson, Nathan; Dave, Keron

    2014-01-01

    The Thermo Scientific SureTect Listeria species Assay is a new real-time PCR assay for the detection of all species of Listeria in food and environmental samples. This validation study was conducted using the AOAC Research Institute (RI) Performance Tested Methods program to validate the SureTect Listeria species Assay in comparison to the reference method detailed in International Organization for Standardization 11290-1:1996 including amendment 1:2004 in a variety of foods plus plastic and stainless steel. The food matrixes validated were smoked salmon, processed cheese, fresh bagged spinach, cantaloupe, cooked prawns, cooked sliced turkey meat, cooked sliced ham, salami, pork frankfurters, and raw ground beef. All matrixes were tested by Thermo Fisher Scientific, Microbiology Division, Basingstoke, UK. In addition, three matrixes (pork frankfurters, fresh bagged spinach, and stainless steel surface samples) were analyzed independently as part of the AOAC-RI-controlled independent laboratory study by the University ofGuelph, Canada. Using probability of detection statistical analysis, a significant difference in favour of the SureTect assay was demonstrated between the SureTect and reference method for high level spiked samples of pork frankfurters, smoked salmon, cooked prawns, stainless steel, and low-spiked samples of salami. For all other matrixes, no significant difference was seen between the two methods during the study. Inclusivity testing was conducted with 68 different isolates of Listeria species, all of which were detected by the SureTect Listeria species Assay. None of the 33 exclusivity isolates were detected by the SureTect Listeria species Assay. Ruggedness testing was conducted to evaluate the performance of the assay with specific method deviations outside of the recommended parameters open to variation, which demonstrated that the assay gave reliable performance. Accelerated stability testing was additionally conducted, validating the assay

  16. Evaluation of the Thermo Scientific SureTect Salmonella species assay. AOAC Performance Tested Method 051303.

    PubMed

    Cloke, Jonathan; Clark, Dorn; Radcliff, Roy; Leon-Velarde, Carlos; Larson, Nathan; Dave, Keron; Evans, Katharine; Crabtree, David; Hughes, Annette; Simpson, Helen; Holopainen, Jani; Wickstrand, Nina; Kauppinen, Mikko

    2014-01-01

    The Thermo Scientific SureTect Salmonella species Assay is a new real-time PCR assay for the detection of Salmonellae in food and environmental samples. This validation study was conducted using the AOAC Research Institute (RI) Performance Tested Methods program to validate the SureTect Salmonella species Assay in comparison to the reference method detailed in International Organization for Standardization 6579:2002 in a variety of food matrixes, namely, raw ground beef, raw chicken breast, raw ground pork, fresh bagged lettuce, pork frankfurters, nonfat dried milk powder, cooked peeled shrimp, pasteurized liquid whole egg, ready-to-eat meal containing beef, and stainless steel surface samples. With the exception of liquid whole egg and fresh bagged lettuce, which were tested in-house, all matrixes were tested by Marshfield Food Safety, Marshfield, WI, on behalf of Thermo Fisher Scientific. In addition, three matrixes (pork frankfurters, lettuce, and stainless steel surface samples) were analyzed independently as part of the AOAC-RI-controlled laboratory study by the University of Guelph, Canada. No significant difference by probability of detection or McNemars Chi-squared statistical analysis was found between the candidate or reference methods for any of the food matrixes or environmental surface samples tested during the validation study. Inclusivity and exclusivity testing was conducted with 117 and 36 isolates, respectively, which demonstrated that the SureTect Salmonella species Assay was able to detect all the major groups of Salmonella enterica subspecies enterica (e.g., Typhimurium) and the less common subspecies of S. enterica (e.g., arizoniae) and the rarely encountered S. bongori. None of the exclusivity isolates analyzed were detected by the SureTect Salmonella species Assay. Ruggedness testing was conducted to evaluate the performance of the assay with specific method deviations outside of the recommended parameters open to variation (enrichment time

  17. Thermal Performance Testing of Cryogenic Insulation Systems

    NASA Technical Reports Server (NTRS)

    Fesmire, James E.; Augustynowicz, Stan D.; Scholtens, Brekke E.

    2007-01-01

    Efficient methods for characterizing thermal performance of materials under cryogenic and vacuum conditions have been developed. These methods provide thermal conductivity data on materials under actual-use conditions and are complementary to established methods. The actual-use environment of full temperature difference in combination with vacuum-pressure is essential for understanding insulation system performance. Test articles include solids, foams, powders, layered blankets, composite panels, and other materials. Test methodology and apparatus design for several insulation test cryostats are discussed. The measurement principle is liquid nitrogen boil-off calorimetry. Heat flux capability ranges from approximately 0.5 to 500 watts per square meter; corresponding apparent thermal conductivity values range from below 0.01 up to about 60 mW/m- K. Example data for different insulation materials are also presented. Upon further standardization work, these patented insulation test cryostats can be available to industry for a wide range of practical applications.

  18. Corrosion performance tests for reinforcing steel in concrete : test procedures.

    DOT National Transportation Integrated Search

    2009-09-01

    The existing test method to assess the corrosion performance of reinforcing steel embedded in concrete, mainly : ASTM G109, is labor intensive, time consuming, slow to provide comparative results, and often expensive. : However, corrosion of reinforc...

  19. Nutritional and productive performance of dairy cows fed corn silage or sugarcane silage with or without additives.

    PubMed

    de Andrade, Felipe Leite; Rodrigues, João Paulo Pacheco; Detmann, Edenio; Valadares Filho, Sebastião de Campos; Castro, Marcelo Messias Duarte; Trece, Aline Souza; Silva, Tadeu Eder; Fischer, Vivian; Weiss, Kirsten; Marcondes, Marcos Inácio

    2016-04-01

    The objective of this study was to compare the intake, digestibility, and performance of dairy cows fed corn silage, fresh sugarcane, and sugarcane ensiled in three different forms. Twenty-five Holstein cows at 114 ± 12.6 days in milk (DIM) were used. A randomized block design was adopted, using an arrangement of repeated measures over time. The following treatments were tested: corn silage (CS); fresh sugarcane (FS); sugarcane silage without additives (SCS); sugarcane silage enriched with calcium oxide at 5 g/kg of forage (SCSc); and sugarcane silage enriched with Lactobacillus buchneri at 5 × 10(4) cfu/kg of forage (SCSb). The roughage to concentrate ratio was 60:40 for the CS diet and 40:60 for the sugarcane-based diets. The dry matter intake (DMI) as a function of body weight had a downward trend for the cows fed sugarcane silage, compared with those fed FS. The sugarcane silages had higher digestibilities of dry matter (DM), organic matter (OM), and neutral detergent fiber (NDFap), compared with FS. The use of L. buchneri or calcium oxide improved the diet's digestibility. The use of FS, sugarcane silage, or sugarcane silage with additives had no effects on milk and fat-corrected milk yield, compared to corn silage. Cows fed FS presented lower milk total solids content and had a downward trend for milk fat, compared with cows fed sugarcane-silage diets. Cows fed sugarcane silages produced milk with higher casein stability in the alcohol test than cows fed fresh-sugarcane diet. Sugarcane silage, with or without additives, did not reduce the intake of dairy cows, and the use of additives improved the fiber's digestibility.

  20. GPS Device Testing Based on User Performance Metrics

    DOT National Transportation Integrated Search

    2015-10-02

    1. Rationale for a Test Program Based on User Performance Metrics ; 2. Roberson and Associates Test Program ; 3. Status of, and Revisions to, the Roberson and Associates Test Program ; 4. Comparison of Roberson and DOT/Volpe Programs

  1. Implementation and performance test of cloud platform based on Hadoop

    NASA Astrophysics Data System (ADS)

    Xu, Jingxian; Guo, Jianhong; Ren, Chunlan

    2018-01-01

    Hadoop, as an open source project for the Apache foundation, is a distributed computing framework that deals with large amounts of data and has been widely used in the Internet industry. Therefore, it is meaningful to study the implementation of Hadoop platform and the performance of test platform. The purpose of this subject is to study the method of building Hadoop platform and to study the performance of test platform. This paper presents a method to implement Hadoop platform and a test platform performance method. Experimental results show that the proposed test performance method is effective and it can detect the performance of Hadoop platform.

  2. 42 CFR 493.1421 - Condition: Laboratories performing moderate complexity testing; testing personnel.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing moderate complexity testing; testing personnel. 493.1421 Section 493.1421 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION...

  3. 42 CFR 493.1421 - Condition: Laboratories performing moderate complexity testing; testing personnel.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing moderate complexity testing; testing personnel. 493.1421 Section 493.1421 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION...

  4. Performance, Cognition, and Physiological Responding in Test Anxiety.

    ERIC Educational Resources Information Center

    Holroyd, Kenneth A.; And Others

    1978-01-01

    This research was designed to clarify the role of autonomic response and evaluative self-awareness in test anxiety. Autonomic, self-report, and performance measures of anxiety were collected from both test-anxious and non-test-anxious individuals in an analogue testing situation under three experimental conditions. Results support cognitive…

  5. Predictors of invalid neuropsychological test performance after traumatic brain injury.

    PubMed

    Moore, Bret A; Donders, Jacobus

    2004-10-01

    To investigate the usefulness of the Test of Memory Malingering (TOMM) and the California Verbal Learning Test-Second Edition (CVLT-II) in assessing invalid test performance after traumatic brain injury (TBI). Consecutive 3-year series of rehabilitation referrals (n = 132). Percentage of participants who failed validity criteria was determined. Hierarchical logistic regression analysis and odds ratios were used to identify predictors of invalid test performance. Twenty patients (15%) performed in the invalid range when held to a priori specified criteria for invalid test performance (i.e. TOMM <45/50 on Trial 2 or CVLT-II <15/16 on Forced-Choice recognition trial). Both psychiatric history and financial compensation seeking were associated with an almost 4-fold increase in likelihood of invalid responding. The TOMM and CVLT-II are sensitive to the potential impact of current financial compensation seeking and prior psychiatric history on neuropsychological test performance after TBI.

  6. Development of a test protocol for evaluating EVA glove performance

    NASA Technical Reports Server (NTRS)

    Hinman, Elaine M.

    1992-01-01

    Testing gloved hand performance involves work from several disciplines. Evaluations performed in the course of reenabling a disabled hand, designing a robotic end effector or master controller, or hard-suit design have all yielded relevant information, and, in most cases, produced performance test methods. Most times, these test methods have been primarily oriented toward their parent discipline. For space operations, a comparative test which would provide a way to quantify pressure glove and end effector performance would be useful in dividing tasks between humans and robots. Such a test would have to rely heavily on sensored measurement, as opposed to questionnaires, to produce relevant data. However, at some point human preference would have to be taken into account. This paper presents a methodology for evaluating gloved hand performance which attempts to respond to these issues. Glove testing of a prototype glove design using this method is described.

  7. Providing Extrinsic Reward for Test Performance Undermines Long-Term Memory Acquisition

    PubMed Central

    Kuhbandner, Christof; Aslan, Alp; Emmerdinger, Kathrin; Murayama, Kou

    2016-01-01

    Based on numerous studies showing that testing studied material can improve long-term retention more than restudying the same material, it is often suggested that the number of tests in education should be increased to enhance knowledge acquisition. However, testing in real-life educational settings often entails a high degree of extrinsic motivation of learners due to the common practice of placing important consequences on the outcome of a test. Such an effect on the motivation of learners may undermine the beneficial effects of testing on long-term memory because it has been shown that extrinsic motivation can reduce the quality of learning. To examine this issue, participants learned foreign language vocabulary words, followed by an immediate test in which one-third of the words were tested and one-third restudied. To manipulate extrinsic motivation during immediate testing, participants received either monetary reward contingent on test performance or no reward. After 1 week, memory for all words was tested. In the immediate test, reward reduced correct recall and increased commission errors, indicating that reward reduced the number of items that can benefit from successful retrieval. The results in the delayed test revealed that reward additionally reduced the gain received from successful retrieval because memory for initially successfully retrieved words was lower in the reward condition. However, testing was still more effective than restudying under reward conditions because reward undermined long-term memory for concurrently restudied material as well. These findings indicate that providing performance–contingent reward in a test can undermine long-term knowledge acquisition. PMID:26869978

  8. Interactions between the concentration of non-starch polysaccharides in wheat and the addition of an enzyme mixture in a broiler digestibility and performance trial.

    PubMed

    Smeets, N; Nuyens, F; Van Campenhout, L; Delezie, E; Niewold, T A

    2018-06-01

    Two broiler trials were designed to investigate the relationship between the concentration of non-starch polysaccharides (NSP) in wheat and 1) its nutritional value for broilers and 2) the efficacy of exogenous enzymes. In a balance trial, diets were formulated with 3 wheat cultivars (Rustic and Viscount-medium NSP, Centenaire-high NSP) and were tested with or without the addition of an exogenous enzyme mixture. The diets were fed to 144 male Ross 308 broiler chickens housed in digestibility cages. Total tract nutrient digestibilities and AMEn were measured from 18 to 22 d of age. In a performance trial, diets were formulated with wheat (medium NSP diet) or with wheat mixed with rye and barley (high NSP diet) and were tested with or without the addition of an exogenous enzyme mixture. The diets were fed to 960 male Ross 308 broilers housed in pens and broiler performance during starter, grower and finisher periods was measured.In the balance trial, wheat cultivar did not affect nutrient digestibility or AMEn. Enzyme addition caused a significant increase in nutrient digestibilities and AMEn for the diet formulated with the high NSP wheat Centenaire only. In the performance trial, feeding the high NSP diet resulted in a higher feed conversion ratio and lower final body weight compared to the medium NSP diet. The largest improvements by enzyme addition were observed in the high NSP diet.In conclusion, the study was not able to show a consistent relationship between the NSP concentration of wheat and its nutritional value, but did demonstrate that the effect of an enzyme mixture on nutrient digestibility or broiler performance depends upon the NSP concentration in the diet.

  9. Interactions between the concentration of non-starch polysaccharides in wheat and the addition of an enzyme mixture in a broiler digestibility and performance trial

    PubMed Central

    Smeets, N; Nuyens, F; Van Campenhout, L; Delezie, E; Niewold, T A

    2018-01-01

    ABSTRACT Two broiler trials were designed to investigate the relationship between the concentration of non-starch polysaccharides (NSP) in wheat and 1) its nutritional value for broilers and 2) the efficacy of exogenous enzymes. In a balance trial, diets were formulated with 3 wheat cultivars (Rustic and Viscount—medium NSP, Centenaire—high NSP) and were tested with or without the addition of an exogenous enzyme mixture. The diets were fed to 144 male Ross 308 broiler chickens housed in digestibility cages. Total tract nutrient digestibilities and AMEn were measured from 18 to 22 d of age. In a performance trial, diets were formulated with wheat (medium NSP diet) or with wheat mixed with rye and barley (high NSP diet) and were tested with or without the addition of an exogenous enzyme mixture. The diets were fed to 960 male Ross 308 broilers housed in pens and broiler performance during starter, grower and finisher periods was measured. In the balance trial, wheat cultivar did not affect nutrient digestibility or AMEn. Enzyme addition caused a significant increase in nutrient digestibilities and AMEn for the diet formulated with the high NSP wheat Centenaire only. In the performance trial, feeding the high NSP diet resulted in a higher feed conversion ratio and lower final body weight compared to the medium NSP diet. The largest improvements by enzyme addition were observed in the high NSP diet. In conclusion, the study was not able to show a consistent relationship between the NSP concentration of wheat and its nutritional value, but did demonstrate that the effect of an enzyme mixture on nutrient digestibility or broiler performance depends upon the NSP concentration in the diet. PMID:29471412

  10. Embedded performance validity testing in neuropsychological assessment: Potential clinical tools.

    PubMed

    Rickards, Tyler A; Cranston, Christopher C; Touradji, Pegah; Bechtold, Kathleen T

    2018-01-01

    The article aims to suggest clinically-useful tools in neuropsychological assessment for efficient use of embedded measures of performance validity. To accomplish this, we integrated available validity-related and statistical research from the literature, consensus statements, and survey-based data from practicing neuropsychologists. We provide recommendations for use of 1) Cutoffs for embedded performance validity tests including Reliable Digit Span, California Verbal Learning Test (Second Edition) Forced Choice Recognition, Rey-Osterrieth Complex Figure Test Combination Score, Wisconsin Card Sorting Test Failure to Maintain Set, and the Finger Tapping Test; 2) Selecting number of performance validity measures to administer in an assessment; and 3) Hypothetical clinical decision-making models for use of performance validity testing in a neuropsychological assessment collectively considering behavior, patient reporting, and data indicating invalid or noncredible performance. Performance validity testing helps inform the clinician about an individual's general approach to tasks: response to failure, task engagement and persistence, compliance with task demands. Data-driven clinical suggestions provide a resource to clinicians and to instigate conversation within the field to make more uniform, testable decisions to further the discussion, and guide future research in this area.

  11. Individual differences in infant fearfulness and cognitive performance: a testing, performance, or competence effect?

    PubMed

    Rieser-Danner, Loretta A

    2003-02-01

    The author conducted 2 studies to examine the relations between infant fear and cognitive testing performance in 12-month-old infants. In Study 1, fear was assessed by using 2 standard temperament questionnaires and a laboratory-based, standardized stranger approach. Individual differences in cognitive development were assessed using the Object Permanence Scale of the Infant Psychological Development Scales (I. C. Uzgiris & J. M. Hunt, 1975). All 3 assessments of fear significantly predicted object permanence performance, with correlations ranging from -.32 to -.35. In Study 2, fear was assessed via a maternal report questionnaire, and habituation performance was assessed via a basic-level categorization task. Familiarity with the examiner and with the testing environment was manipulated to test for a familiarity influence on performance. Testing revealed individual differences in both fear and habituation. Results suggest that highly fearful infants required more trials to habituate and were less likely to meet the habituation criterion than infants who were less fearful. Methodological and conceptual implications of these results are discussed.

  12. 10 CFR 26.168 - Blind performance testing.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... analyte and must be certified by immunoassay and confirmatory testing; (2) Drug positive. These samples must contain a measurable amount of the target drug or analyte in concentrations ranging between 150... performance test sample must contain a measurable amount of the target drug or analyte in concentrations...

  13. 10 CFR 26.168 - Blind performance testing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... analyte and must be certified by immunoassay and confirmatory testing; (2) Drug positive. These samples must contain a measurable amount of the target drug or analyte in concentrations ranging between 150... performance test sample must contain a measurable amount of the target drug or analyte in concentrations...

  14. 10 CFR 26.168 - Blind performance testing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... analyte and must be certified by immunoassay and confirmatory testing; (2) Drug positive. These samples must contain a measurable amount of the target drug or analyte in concentrations ranging between 150... performance test sample must contain a measurable amount of the target drug or analyte in concentrations...

  15. 10 CFR 26.168 - Blind performance testing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... analyte and must be certified by immunoassay and confirmatory testing; (2) Drug positive. These samples must contain a measurable amount of the target drug or analyte in concentrations ranging between 150... performance test sample must contain a measurable amount of the target drug or analyte in concentrations...

  16. 10 CFR 26.168 - Blind performance testing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... analyte and must be certified by immunoassay and confirmatory testing; (2) Drug positive. These samples must contain a measurable amount of the target drug or analyte in concentrations ranging between 150... performance test sample must contain a measurable amount of the target drug or analyte in concentrations...

  17. 42 CFR 493.1487 - Condition: Laboratories performing high complexity testing; testing personnel.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing high complexity testing; testing personnel. 493.1487 Section 493.1487 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  18. 42 CFR 493.1487 - Condition: Laboratories performing high complexity testing; testing personnel.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Laboratories performing high complexity testing; testing personnel. 493.1487 Section 493.1487 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY...

  19. Performance testing of lidar receivers

    NASA Technical Reports Server (NTRS)

    Shams, M. Y.

    1986-01-01

    In addition to the considerations about the different types of noise sources, dynamic range, and linearity of a lidar receiver, one requires information about the pulse shape retaining capabilities of the receiver. For this purpose, relatively precise information about the height resolution as well as the recovery time of the receiver, due both to large transients and to fast changes in the received signal, is required. As more and more analog receivers using fast analog to digital converters and transient recorders will be used in the future lidar systems, methods to test these devices are essential. The method proposed for this purpose is shown. Tests were carried out using LCW-10, LT-20, and FTVR-2 as optical parts of the optical pulse generator circuits. A commercial optical receiver, LNOR, and a transient recorder, VK 220-4, were parts of the receiver system.

  20. The effect of additional joint mobilization on neuromuscular performance in individuals with functional ankle instability.

    PubMed

    Shih, Yi-Fen; Yu, Hsiang-Ting; Chen, Wen-Yin; Liao, Kwong-Kum; Lin, Hsiu-Chen; Yang, Yea-Ru

    2018-03-01

    To examine the effects of joint mobilization and exercise training on neuromuscular performance in individuals with functional ankle instability (FAI). A cross-sectional study. Forty five subjects with FAI were randomized into three groups: control (CG, n = 15, 27.9 ± 6.6yr), training (TG, n = 15, 26.9 ± 5.8yr) and mobilization with training group (MTG, n = 15, 26.5 ± 4.8yr). Four weeks of neuromuscular training for TG; neuromuscular training and joint mobilization for MTG. Electromyography of the peroneus longus (PL), tibialis anterior (TA), and soleus (SOL) and the reaching distance of the Y balance test (YBT), dorsiflexion range of motion (DFROM), Cumberland ankle instability tool (CAIT), and global rating scale (GRS). Two-way repeated measures MANOVA were used with the significance level p < .05. MANOVA found significant group by time interactions on posterolateral reaching distance (p = .032), PL activation (p = .006-.03), DFROM (p < .001), CAIT (p < .001) and GRS (p < .001). The post hoc tests indicated significantly improved PL muscle activity and posterolateral reaching distance for MTG compared to TG (p = .004) and CG (p = .006). Joint mobilization resulted in additional benefits on self-reported ankle instability severity, dorsiflexion mobility, and posterolateral balance performance in individuals with FAI, but its effects on general improvement, muscle activation, and other balance tasks remained uncertain. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. The relationship between the yo-yo tests, anaerobic performance and aerobic performance in young soccer players.

    PubMed

    Karakoç, Barış; Akalan, Cengiz; Alemdaroğlu, Utku; Arslan, Erşan

    2012-12-01

    The purposes of this study were to determine the relationship between performance in the Yo-Yo intermittent recovery test level 1 (YIRT1), the Yo-Yo intermittent recovery test level 2 (YIRT2) and the Yo-Yo endurance test (continuous) (YET) with maximal oxygen uptake (VO2max) and Wingate anaerobic performance (WaNT) test results in young soccer players (age 15.00 ± 0.0 years, body height 176.3 ± 4.2 cm and body mass 68.1 ± 3.6 kg). An ergospirometry device was used during the treadmill test (TRT) to determine VO2max. At the end of the study, significant differences were found between the Yo-Yo tests and TRT in terms of HRmax (TRT = 195,92, YIRT1 = 197,83, YIRT2 = 198,5 YET = 198) (p > 0.05). While there were moderate correlations between VO2max and YIRT 1-2 performances (respectively, r = 0.56, r = 0.53), there was only a weak relationship between VO2max and YET performance (r = 0.43) (distance covered). There were also moderate significant negative correlations between performance in the YIRT2 and peak power measured in the WaNT (r = -0.55), although there were no significant correlations between performance in the three tests and average power. A moderate negative correlation was found between performance in the YIRT2 and Fatigue index (FI) (r = -0,66). In conclusion, the YIRT2 may be a more suitable field test for determining both aerobic and anaerobic performance in soccer players.

  2. The Relationship Between the Yo-Yo Tests, Anaerobic Performance and Aerobic Performance in Young Soccer Players

    PubMed Central

    Karakoç, Barış; Akalan, Cengiz; Alemdaroğlu, Utku; Arslan, Erşan

    2012-01-01

    The purposes of this study were to determine the relationship between performance in the Yo-Yo intermittent recovery test level 1 (YIRT1), the Yo-Yo intermittent recovery test level 2 (YIRT2) and the Yo-Yo endurance test (continuous) (YET) with maximal oxygen uptake (VO2max) and Wingate anaerobic performance (WaNT) test results in young soccer players (age 15.00 ± 0.0 years, body height 176.3 ± 4.2 cm and body mass 68.1 ± 3.6 kg). An ergospirometry device was used during the treadmill test (TRT) to determine VO2max. At the end of the study, significant differences were found between the Yo-Yo tests and TRT in terms of HRmax (TRT = 195,92, YIRT1 = 197,83, YIRT2 = 198,5 YET = 198) (p > 0.05). While there were moderate correlations between VO2max and YIRT 1–2 performances (respectively, r = 0.56, r = 0.53), there was only a weak relationship between VO2max and YET performance (r = 0.43) (distance covered). There were also moderate significant negative correlations between performance in the YIRT2 and peak power measured in the WaNT (r = −0.55), although there were no significant correlations between performance in the three tests and average power. A moderate negative correlation was found between performance in the YIRT2 and Fatigue index (FI) (r = −0,66). In conclusion, the YIRT2 may be a more suitable field test for determining both aerobic and anaerobic performance in soccer players. PMID:23486008

  3. [Effects of psychological stress on performances in open-field test of rats and tyrosine's modulation].

    PubMed

    Chen, Wei-Qiang; Cheng, Yi-Yong; Li, Shu-Tian; Hong, Yan; Wang, Dong-Lan; Hou, Yue

    2009-02-01

    To explore the effects of different doses of tyrosine modulation on behavioral performances in open field test of psychological stress rats. The animal model of psychological stress was developed by restraint stress for 21 days. Wistar rats were randomly assigned to five groups (n = 10) as follows: control group (CT), stress control group (SCT), low, medium and high-doses of tyrosine modulation stress groups (SLT, SMT and SIT). The changes of behavioral performances were examined by open-field test. Serum levels of cortisol, norepinephrine and dopamine were also detected. The levels of serum cortisol were all increased obviously in the four stress groups, and their bodyweight gainings were diminished. The behavioral performances of SCT rats in open-field test were changed significantly in contrast to that of CT rats. However, The behavioral performances of SMT and SHT rats were not different from that of CT rats. In addition, the serum levels of norepinephrine and dopamine were downregulated obviously in SCT and SLT groups, and no differences were observed in other groups. Psychological stress can impair body behavioral performances, and moderate tyrosine modulation may improve these abnormal changes. The related mechanisms may be involved with the changes of norepinephrine and dopamine.

  4. Functional performance testing in participants with functional ankle instability and in a healthy control group.

    PubMed

    Buchanan, Amanda S; Docherty, Carrie L; Schrader, John

    2008-01-01

    Functional ankle instability (FAI) affects a large part of the population. Inconsistent findings have been reported regarding the existence of functional performance deficits in individuals with FAI. To examine functional performance in participants with FAI compared with participants in a control group during 2 hopping tests. Case-control study. Athletic training research laboratory. There were 40 college-aged individuals who participated in our study: 20 with FAI and 20 without FAI. We defined FAI as history of an ankle sprain and residual episodes of "giving way." Participants completed 2 functional performance tests (FPTs): the single-limb hopping and the single-limb hurdle tests. Time to complete each test was recorded. Following each FPT, participants were asked if their ankles felt unstable during the test. We found no difference between participants in the FAI and control groups for the hopping or hurdle tests (P > .05). When asked if their ankles felt unstable during the FPTs, approximately half of the participants in the FAI group and none of the participants in the control group reported a feeling of instability. Subsequently, a secondary analysis of variance was calculated with participants grouped into 3 categories: control participants, FAI participants reporting instability symptoms during FPT (FAI-S), and FAI participants not reporting instability symptoms during FPT (FAI-NS). Results revealed a difference among the 3 groups for the single-limb hopping test (P < .01). Post hoc analysis revealed a difference between the FAI-S participants and both the control and the FAI-NS participants. No difference was identified for the single-limb hurdle test (P = .41). The FAI-S participants had performance deficits during the single-limb hopping test. Therefore, clinicians could use this simple hopping test as an additional method to determine the presence of FAI.

  5. Power Performance Test Report for the Viryd CS8 Wind Turbine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roadman, J.; Murphy, M.; van Dam, J.

    2012-12-01

    This report contains the results of the power performance test that was performed on a Viryd CS8 wind turbine as part of the DOE Independent Testing project. The test is an accredited test to the IEC 61400-12-1 power performance standard.

  6. Motivational and Cognitive Test-Taking Strategies and Their Influence on Test Performance in Mathematics

    ERIC Educational Resources Information Center

    Peng, Yun; Hong, Eunsook; Mason, Elsa

    2014-01-01

    A structural equation model of relationships among testing-related motivation variables (test value, effort, self-efficacy, and test anxiety), test-taking strategies (test tactics and metacognitive strategies), gender, and math test performance were examined with a sample of 10th graders (N = 438; 182 males and 256 females). In general, motivation…

  7. Play for Performance: Using Computer Games to Improve Motivation and Test-Taking Performance

    ERIC Educational Resources Information Center

    Dennis, Alan R.; Bhagwatwar, Akshay; Minas, Randall K.

    2013-01-01

    The importance of testing, especially certification and high-stakes testing, has increased substantially over the past decade. Building on the "serious gaming" literature and the psychology "priming" literature, we developed a computer game designed to improve test-taking performance using psychological priming. The game primed…

  8. Performance Testing in Electronic Technology. Final Report.

    ERIC Educational Resources Information Center

    Williamson, Bert; Pedersen, Joe F.

    This set of 21 performance tests in electronics technology was developed on the basis of a review of commercial and noncommercial instructional materials dealing with electronics technology. The tests, which were reviewed by a group of community college instructors and an advisory committee for electronics technology, address the following…

  9. 40 CFR 610.35 - Driveability and performance tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Driveability and performance tests. 610.35 Section 610.35 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria...

  10. 40 CFR 610.35 - Driveability and performance tests.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Driveability and performance tests. 610.35 Section 610.35 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria...

  11. 40 CFR 610.35 - Driveability and performance tests.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Driveability and performance tests. 610.35 Section 610.35 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria...

  12. 40 CFR 610.35 - Driveability and performance tests.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Driveability and performance tests. 610.35 Section 610.35 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria...

  13. 40 CFR 610.35 - Driveability and performance tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Driveability and performance tests. 610.35 Section 610.35 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria...

  14. 40 CFR 63.11212 - What stack tests and procedures must I use for the performance tests?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 15 2014-07-01 2014-07-01 false What stack tests and procedures must I use for the performance tests? 63.11212 Section 63.11212 Protection of Environment ENVIRONMENTAL... What stack tests and procedures must I use for the performance tests? (a) You must conduct all...

  15. 40 CFR 63.11212 - What stack tests and procedures must I use for the performance tests?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 14 2011-07-01 2011-07-01 false What stack tests and procedures must I use for the performance tests? 63.11212 Section 63.11212 Protection of Environment ENVIRONMENTAL... What stack tests and procedures must I use for the performance tests? (a) You must conduct all...

  16. 40 CFR 63.11212 - What stack tests and procedures must I use for the performance tests?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 15 2012-07-01 2012-07-01 false What stack tests and procedures must I use for the performance tests? 63.11212 Section 63.11212 Protection of Environment ENVIRONMENTAL... What stack tests and procedures must I use for the performance tests? (a) You must conduct all...

  17. 40 CFR 63.11212 - What stack tests and procedures must I use for the performance tests?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 15 2013-07-01 2013-07-01 false What stack tests and procedures must I use for the performance tests? 63.11212 Section 63.11212 Protection of Environment ENVIRONMENTAL... What stack tests and procedures must I use for the performance tests? (a) You must conduct all...

  18. Metrology test object for dimensional verification in additive manufacturing of metals for biomedical applications.

    PubMed

    Teeter, Matthew G; Kopacz, Alexander J; Nikolov, Hristo N; Holdsworth, David W

    2015-01-01

    Additive manufacturing continues to increase in popularity and is being used in applications such as biomaterial ingrowth that requires sub-millimeter dimensional accuracy. The purpose of this study was to design a metrology test object for determining the capabilities of additive manufacturing systems to produce common objects, with a focus on those relevant to medical applications. The test object was designed with a variety of features of varying dimensions, including holes, cylinders, rectangles, gaps, and lattices. The object was built using selective laser melting, and the produced dimensions were compared to the target dimensions. Location of the test objects on the build plate did not affect dimensions. Features with dimensions less than 0.300 mm did not build or were overbuilt to a minimum of 0.300 mm. The mean difference between target and measured dimensions was less than 0.100 mm in all cases. The test object is applicable to multiple systems and materials, tests the effect of location on the build, uses a minimum of material, and can be measured with a variety of efficient metrology tools (including measuring microscopes and micro-CT). Investigators can use this test object to determine the limits of systems and adjust build parameters to achieve maximum accuracy. © IMechE 2014.

  19. Design and Preliminary Performance Testing of Electronegative Gas Plasma Thruster

    NASA Technical Reports Server (NTRS)

    Liu, Thomas M.; Schloeder, Natalie R.; Walker, Mitchell L. R.; Polzin, Kurt A.; Dankanich, John W.; Aanesland, Ane

    2014-01-01

    In classical gridded electrostatic ion thrusters, positively charged ions are generated from a plasma discharge of noble gas propellant and accelerated to provide thrust. To maintain overall charge balance on the propulsion system, a separate electron source is required to neutralize the ion beam as it exits the thruster. However, if high-electronegativity propellant gases (e.g., sulfur hexafluoride) are instead used, a plasma discharge can result consisting of both positively and negatively charged ions. Extracting such electronegative plasma species for thrust generation (e.g., with time-varying, bipolar ion optics) would eliminate the need for a separate neutralizer cathode subsystem. In addition for thrusters utilizing a RF plasma discharge, further simplification of the ion thruster power system may be possible by also using the RF power supply to bias the ion optics. Recently, the PEGASES (Plasma propulsion with Electronegative gases) thruster prototype successfully demonstrated proof-of-concept operations in alternatively accelerating positively and negatively charged ions from a RF discharge of a mixture of argon and sulfur hexafluoride.i In collaboration with NASA Marshall Space Flight Center (MSFC), the Georgia Institute of Technology High-Power Electric Propulsion Laboratory (HPEPL) is applying the lessons learned from PEGASES design and testing to develop a new thruster prototype. This prototype will incorporate design improvements and undergo gridless operational testing and diagnostics checkout at HPEPL in April 2014. Performance mapping with ion optics will be conducted at NASA MSFC starting in May 2014. The proposed paper discusses the design and preliminary performance testing of this electronegative gas plasma thruster prototype.

  20. Development, construct validity and test-retest reliability of a field-based wheelchair mobility performance test for wheelchair basketball.

    PubMed

    de Witte, Annemarie M H; Hoozemans, Marco J M; Berger, Monique A M; van der Slikke, Rienk M A; van der Woude, Lucas H V; Veeger, Dirkjan H E J

    2018-01-01

    The aim of this study was to develop and describe a wheelchair mobility performance test in wheelchair basketball and to assess its construct validity and reliability. To mimic mobility performance of wheelchair basketball matches in a standardised manner, a test was designed based on observation of wheelchair basketball matches and expert judgement. Forty-six players performed the test to determine its validity and 23 players performed the test twice for reliability. Independent-samples t-tests were used to assess whether the times needed to complete the test were different for classifications, playing standards and sex. Intraclass correlation coefficients (ICC) were calculated to quantify reliability of performance times. Males performed better than females (P < 0.001, effect size [ES] = -1.26) and international men performed better than national men (P < 0.001, ES = -1.62). Performance time of low (≤2.5) and high (≥3.0) classification players was borderline not significant with a moderate ES (P = 0.06, ES = 0.58). The reliability was excellent for overall performance time (ICC = 0.95). These results show that the test can be used as a standardised mobility performance test to validly and reliably assess the capacity in mobility performance of elite wheelchair basketball athletes. Furthermore, the described methodology of development is recommended for use in other sports to develop sport-specific tests.

  1. Impact of high-performance work systems on individual- and branch-level performance: test of a multilevel model of intermediate linkages.

    PubMed

    Aryee, Samuel; Walumbwa, Fred O; Seidu, Emmanuel Y M; Otaye, Lilian E

    2012-03-01

    We proposed and tested a multilevel model, underpinned by empowerment theory, that examines the processes linking high-performance work systems (HPWS) and performance outcomes at the individual and organizational levels of analyses. Data were obtained from 37 branches of 2 banking institutions in Ghana. Results of hierarchical regression analysis revealed that branch-level HPWS relates to empowerment climate. Additionally, results of hierarchical linear modeling that examined the hypothesized cross-level relationships revealed 3 salient findings. First, experienced HPWS and empowerment climate partially mediate the influence of branch-level HPWS on psychological empowerment. Second, psychological empowerment partially mediates the influence of empowerment climate and experienced HPWS on service performance. Third, service orientation moderates the psychological empowerment-service performance relationship such that the relationship is stronger for those high rather than low in service orientation. Last, ordinary least squares regression results revealed that branch-level HPWS influences branch-level market performance through cross-level and individual-level influences on service performance that emerges at the branch level as aggregated service performance.

  2. Testing Solutions for Adult Film Performers.

    PubMed

    Bergman, Zachary R

    2014-01-01

    The majority of the nation's adult films are produced in California, and within California, most production occurs in Los Angeles. In order to regulate that content, the County of Los Angeles passed the Safer Sex in the Adult Film Industry Act (Measure B) by way of referendum in November 2012. Measure B requires that adult film producers wishing to film in Los Angeles County obtain permits from the Los Angeles County Department of Public Health, and it also mandates that adult film performers use condoms while filming and "engaging in anal or vaginal sexual intercourse." Nevertheless, between August 2013 and January 2014, several adult film performers in California tested positive for HIV, and the threat of infection remains. Although Measure B is not the best way forward for Los Angeles County, elements of the ordinance should be incorporated into future legislative efforts. Given the economic ramifications of industry flight due to more localized regulations, this Note concludes that California should pass statewide comprehensive reform. Any such new legislation must treat "independent contractors," the classification generally used for adult film performs, as if they were regular employees. Legislation should also couple mandatory testing mechanisms with provisions granting performers the right to choose whether they use condoms. Finally, legislation must include mechanisms that ensure performers' preferences are not improperly tainted by outside forces and pressures. While there will always be risks associated with the production of adult content, if undertaken, these reforms could significantly mitigate those hazards.

  3. Test-Taker Characteristics and Integrated Speaking Test Performance: A Path-Analytic Study

    ERIC Educational Resources Information Center

    Huang, Heng-Tsung Danny; Hung, Shao-Ting Alan; Hong, He-Ting Vivian

    2016-01-01

    This study explored the relationships among language proficiency, two selected test-taker characteristics (i.e., topical knowledge and anxiety), and integrated speaking test performance. Data collection capitalized on three sets of instruments: three integrated tasks derived from TOEFL-iBT preparation materials, the state anxiety inventory created…

  4. Users manual for the Automated Performance Test System (APTS)

    NASA Technical Reports Server (NTRS)

    Lane, N. E.; Kennedy, R. S.

    1990-01-01

    The characteristics of and the user information for the Essex Automated Performance Test System (APTS) computer-based portable performance assessment battery are given. The battery was developed to provide a menu of performance test tapping the widest possible variety of human cognitive and motor functions, implemented on a portable computer system suitable for use in both laboratory and field settings for studying the effects of toxic agents and other stressors. The manual gives guidance in selecting, administering and scoring tests from the battery, and reviews the data and studies underlying the development of the battery. Its main emphasis is on the users of the battery - the scientists, researchers and technicians who wish to examine changes in human performance across time or as a function of changes in the conditions under which test data are obtained. First the how to information needed to make decisions about where and how to use the battery is given, followed by the research background supporting the battery development. Further, the development history of the battery focuses largely on the logical framework within which tests were evaluated.

  5. Relationships among Testing Medium, Test Performance, and Testing Time of High School Students Who Are Visually Impaired

    ERIC Educational Resources Information Center

    Erin, Jane N.; Hong, Sunggye; Schoch, Christina; Kuo, YaJu

    2006-01-01

    This study compared the test scores and time required by high school students who are blind, sighted, or have low vision to complete tests administered in written and oral formats. The quantitative results showed that the blind students performed better on multiple-choice tests in braille and needed more time while taking tests in braille. The…

  6. Thermodynamic performance testing of the orbiter flash evaporator system

    NASA Technical Reports Server (NTRS)

    Jaax, J. R.; Melgares, M. A.; Frahm, J. P.

    1980-01-01

    System level testing of the space shuttle orbiter's development flash evaporator system (FES) was performed in a thermal vacuum chamber capable of simulating ambient ascent, orbital, and entry temperature and pressure profiles. The test article included the evaporator assembly, high load and topping exhaust duct and nozzle assemblies, and feedwater supply assembly. Steady state and transient heat load, water pressure/temperature and ambient pressure/temperature profiles were imposed by especially designed supporting test hardware. Testing in 1978 verified evaporator and duct heater thermal design, determined FES performance boundaries, and assessed topping evaporator plume characteristics. Testing in 1979 combined the FES with the other systems in the orbiter active thermal control subsystem (ATCS). The FES met or exceeded all nominal and contingency performance requirements during operation with the integrated ATCS. During both tests stability problems were encountered during steady state operations which resulted in subsequent design changes to the water spray nozzle and valve plate assemblies.

  7. End-of-test Performance and Wear Characterization of NASA's Evolutionary Xenon Thruster (NEXT) Long-Duration Test

    NASA Technical Reports Server (NTRS)

    Shastry, Rohit; Herman, Daniel Andrew; Soulas, George C.; Patterson, Michael J.

    2014-01-01

    This presentation describes results from the end-of-test performance characterization of NASA's Evolutionary Xenon Thruster (NEXT) Long-Duration Test (LDT). Sub-component performance as well as overall thruster performance is presented and compared to results over the course of the test. Overall wear of critical thruster components is also described, and an update on the first failure mode of the thruster is provided.

  8. Toward Enhancing Solar Cell Performance: An Effective and "Green" Additive.

    PubMed

    Tan, Long; Li, Pandeng; Zhang, Qingzhe; Izquierdo, Ricardo; Chaker, Mohamed; Ma, Dongling

    2018-02-21

    Performance of bulk heterojunction polymer solar cells (PSCs) highly relies on the morphology of the photoactive layer involving conjugated polymers and fullerene derivatives as donors and acceptors, respectively. Herein, butylamine was found to be able to optimize the morphology of the donor/acceptor (D/A) film composed of a blend of poly(3-hexylthiophene-2,5-diyl) (P3HT) and phenyl-C 61 -butyric acid methyl ester (PCBM). Compared to the commonly used alkane dithiols and halogenated additives with high boiling points, butylamine has a much lower boiling point between 77 and 79 °C, and it is also much "greener". A specific interaction between butylamine and PCBM was demonstrated to account for the morphology improvement. Essentially, butylamine can selectively dissolve PCBM in the P3HT:PCBM blend and facilitate the diffusion of PCBM in the film fabrication processes. Atomic force microscopy and X-ray photoelectron spectroscopy investigations confirmed the formation of the P3HT-enriched top surface and the abundance of PCBM at the bottom side, i.e., the formation of vertical phase segregation, as a consequence of the specific PCBM-butylamine interaction. The D/A film with inhomogeneously distributed D and A components in the vertical film direction, with more P3HT at the hole extraction side and more PCBM at the electron extraction side, enables more efficient charge extraction in the D/A film, reflected by the largely enhanced fill factor. The power conversion efficiency of devices reached 4.03 and 4.61%, respectively, depending on the thickness of the D/A film, and these are among the best values reported for P3HT:PCBM-based devices. As compared to the devices fabricated without the introduction of butylamine under otherwise the same processing conditions, they represented 19.6 and 21.6% improvement in the efficiency, respectively. The discovery of butylamine as a new, effective additive in enhancing the performance of PSCs strongly suggests that the differential

  9. 40 CFR 63.1349 - Performance testing requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...)(1). (4)(i) THC CEMS relative accuracy test. (A) If you are subject to limitations on THC emissions... CEMS, the THC span value (as propane) is 50 ppmvd. You demonstrate compliance with a RATA when the... conducting the performance test for total organic HAP, you must also determine THC emissions by operating a...

  10. 40 CFR 63.1349 - Performance testing requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...)(1). (4)(i) THC CEMS relative accuracy test. (A) If you are subject to limitations on THC emissions... CEMS, the THC span value (as propane) is 50 ppmvd. You demonstrate compliance with a RATA when the... conducting the performance test for total organic HAP, you must also determine THC emissions by operating a...

  11. Performance of conventionally powered vehicles tested to an electric vehicle test procedure

    NASA Technical Reports Server (NTRS)

    Slavik, R. J.; Dustin, M. O.; Lumannick, S.

    1977-01-01

    A conventional Volkswagen transporter, a Renault 5, a Pacer, and a U. S. Postal Service general DJ-5 delivery van were treated to an electric vehicle test procedure in order to allow direct comparison of conventional and electric vehicles. Performance test results for the four vehicles are presented.

  12. The Development of MST Test Information for the Prediction of Test Performances

    ERIC Educational Resources Information Center

    Park, Ryoungsun; Kim, Jiseon; Chung, Hyewon; Dodd, Barbara G.

    2017-01-01

    The current study proposes novel methods to predict multistage testing (MST) performance without conducting simulations. This method, called MST test information, is based on analytic derivation of standard errors of ability estimates across theta levels. We compared standard errors derived analytically to the simulation results to demonstrate the…

  13. Active matrix organic light emitting diode (AMOLED) performance and life test results

    NASA Astrophysics Data System (ADS)

    Fellowes, David A.; Botkin, Michael E.; Draper, Russell S.; Coletta, Jason

    2013-05-01

    The U.S. Army and eMagin Corporation established a Cooperative Research and Development Agreement (CRADA) to characterize the ongoing improvements in the lifetime of OLED displays. This CRADA also called for the evaluation of OLED performance as the need arises, especially when new products are developed or when a previously untested parameter needs to be understood. In 2006, eMagin Corporation developed long-life OLED-XL devices for use in their AMOLED microdisplays for head-worn applications. Through Research and Development programs from 2007 to 2012 with the U.S. Government, eMagin made additional improvements in OLED life and developed the first SXGA (1280 X 1024 with triad pixels) and WUXGA (1920 X 1200 with triad pixels) OLED microdisplays. US Army RDECOM CERDEC NVESD conducted life and performance tests on these displays, publishing results at the 2012, 2011, 2010, 2009, 2008, and 2007 SPIE Defense, Security and Sensing Symposia. Life and performance tests have continued through 2013, and this data will be presented along with a comparison to previous data. This should result in a better understanding of the applicability of AMOLEDs in military and commercial head mounted systems, where good fits are made, and where further development might be desirable.

  14. Active matrix organic light emitting diode (AMOLED) performance and life test results

    NASA Astrophysics Data System (ADS)

    Fellowes, David A.; Wood, Michael V.; Hastings, Arthur R., Jr.; Draper, Russell S.; Ghosh, Amalkumar; Prache, Olivier; Wacyk, Ihor

    2012-06-01

    The US Army and eMagin Corporation established a Cooperative Research and Development Agreement (CRADA) to characterize the ongoing improvements in the lifetime of OLED displays. This CRADA also called for the evaluation of OLED performance as the need arises, especially when new products are developed or when a previously untested parameter needs to be understood. In 2006, eMagin Corporation developed long-life OLED-XL devices for use in their AMOLED microdisplays for head-worn applications. Through Research and Development programs from 2007 to 2011 with the US Government, eMagin made additional improvements in OLED life and developed the first SXGA (1280 X 1024 triad pixels) and WUXGA (1920 X 1200) OLED microdisplays. US Army RDECOM CERDEC NVESD conducted life and performance tests on these displays, publishing results at the 2011, 2010, 2009, 2008, and 2007 SPIE Defense, Security and Sensing Symposia1,2,3,4,5. Life and performance tests have continued through 2012, and this data will be presented along with a recap of previous data. This should result in a better understanding of the applicability of AMOLEDs in military and commercial head mounted systems by determining where good fits are made and where further development might be desirable.

  15. MOON-test - determination of motor performance in the pediatric oncology.

    PubMed

    Götte, M; Kesting, S; Albrecht, C; Worth, A; Bös, K; Boos, J

    2013-05-01

    Pediatric cancer patients suffer from various negative consequences due to the disease, the medical therapy and the inactivity during the intensive treatment. Only few studies have systematically identified the adverse effects of cancer on motor performance in childhood. To determine the motor performance of pediatric cancer patients, a motor performance test was developed which is applicable for this specific patient group. Eight test items with reference values for healthy children were merged to the MOON-test (test for motor performance in the oncology). MOON was tested for feasibility and acceptance in 33 patients aged 4-18 years. Feasibility was confirmed for children with different types of cancer (hematological malignancies and solid tumors) and with amputation, endoprosthesis, during aplasia as well as reduced general condition. Furthermore the patients showed a broad acceptance. Based on the study findings, the use of MOON-test as a standardized motor performance diagnostic tool in clinical routine of oncological acute clinics as well as rehabilitation clinics can be recommended.· © Georg Thieme Verlag KG Stuttgart · New York.

  16. Ionic Liquids as Novel Lubricants and /or Lubricant Additives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qu, J.; Viola, M. B.

    2013-10-31

    This ORNL-GM CRADA developed ionic liquids (ILs) as novel lubricants or oil additives for engine lubrication. A new group of oil-miscible ILs have been designed and synthesized with high thermal stability, non-corrosiveness, excellent wettability, and most importantly effective anti-scuffing/anti-wear and friction reduction characteristics. Mechanistic analysis attributes the superior lubricating performance of IL additives to their physical and chemical interactions with metallic surfaces. Working with a leading lubricant formulation company, the team has successfully developed a prototype low-viscosity engine oil using a phosphonium-phosphate IL as an anti-wear additive. Tribological bench tests of the IL-additized formulated oil showed 20-33% lower friction inmore » mixed and elastohydrodynamic lubrication and 38-92% lower wear in boundary lubrication when compared with commercial Mobil 1 and Mobil Clean 5W-30 engine oils. High-temperature, high load (HTHL) full-size engine tests confirmed the excellent anti-wear performance for the IL-additized engine oil. Sequence VID engine dynamometer tests demonstrated an improved fuel economy by >2% for this IL-additized engine oil benchmarked against the Mobil 1 5W-30 oil. In addition, accelerated catalyst aging tests suggest that the IL additive may potentially have less adverse impact on three-way catalysts compared to the conventional ZDDP. Follow-on research is needed for further development and optimization of IL chemistry and oil formulation to fully meet ILSAC GF-5 specifications and further enhance the automotive engine efficiency and durability.« less

  17. Performance Test Data Analysis of Scintillation Cameras

    NASA Astrophysics Data System (ADS)

    Demirkaya, Omer; Mazrou, Refaat Al

    2007-10-01

    In this paper, we present a set of image analysis tools to calculate the performance parameters of gamma camera systems from test data acquired according to the National Electrical Manufacturers Association NU 1-2001 guidelines. The calculation methods are either completely automated or require minimal user interaction; minimizing potential human errors. The developed methods are robust with respect to varying conditions under which these tests may be performed. The core algorithms have been validated for accuracy. They have been extensively tested on images acquired by the gamma cameras from different vendors. All the algorithms are incorporated into a graphical user interface that provides a convenient way to process the data and report the results. The entire application has been developed in MATLAB programming environment and is compiled to run as a stand-alone program. The developed image analysis tools provide an automated, convenient and accurate means to calculate the performance parameters of gamma cameras and SPECT systems. The developed application is available upon request for personal or non-commercial uses. The results of this study have been partially presented in Society of Nuclear Medicine Annual meeting as an InfoSNM presentation.

  18. Interactions of task and subject variables among continuous performance tests.

    PubMed

    Denney, Colin B; Rapport, Mark D; Chung, Kyong-Mee

    2005-04-01

    Contemporary models of working memory suggest that target paradigm (TP) and target density (TD) should interact as influences on error rates derived from continuous performance tests (CPTs). The present study evaluated this hypothesis empirically in a typically developing, ethnically diverse sample of children. The extent to which scores based on different combinations of these task parameters showed different patterns of relationship to age, intelligence, and gender was also assessed. Four continuous performance tests were derived by combining two target paradigms (AX and repeated letter target stimuli) with two levels of target density (8.3% and 33%). Variations in mean omission (OE) and commission (CE) error rates were examined within and across combinations of TP and TD. In addition, a nested series of structural equation models was utilized to examine patterns of relationship among error rates, age, intelligence, and gender. Target paradigm and target density interacted as influences on error rates. Increasing density resulted in higher OE and CE rates for the AX paradigm. In contrast, the high density condition yielded a decline in OE rates accompanied by a small increase in CEs using the repeated letter CPT. Target paradigms were also distinguishable on the basis of age when using OEs as the performance measure, whereas combinations of age and intelligence distinguished between density levels but not target paradigms using CEs as the dependent measure. Different combinations of target paradigm and target density appear to yield scores that are conceptually and psychometrically distinguishable. Consequently, developmentally appropriate interpretation of error rates across tasks may require (a) careful analysis of working memory and attentional resources required for successful performance, and (b) normative data bases that are differently stratified with respect to combinations of age and intelligence.

  19. Consideration of "g" as a Common Antecedent for Cognitive Ability Test Performance, Test Motivation, and Perceived Fairness

    ERIC Educational Resources Information Center

    Reeve, Charlie L.; Lam, Holly

    2007-01-01

    Several different analyses were used to test the hypothesis that test-taking motivation, perceived test fairness, and actual test performance are correlated only because they share a common antecedent. First, hierarchical regressions reveal that initial test performance has a unique influence on non-ability factors even after controlling for…

  20. Diagnostic performances of clinical laboratory tests using Triton X-100 to reduce the biohazard associated with routine testing of Ebola virus-infected patients.

    PubMed

    Tempestilli, Massimo; Pucci, Luigia; Notari, Stefania; Di Caro, Antonino; Castilletti, Concetta; Rivelli, Maria Rosaria; Agrati, Chiara; Pucillo, Leopoldo Paolo

    2015-11-01

    Ebola virus, an enveloped virus, is the cause of the largest and most complex Ebola virus disease (EVD) outbreak in West Africa. Blood or body fluids of an infected person may represent a biohazard to laboratory workers. Laboratory tests of virus containing specimens should be conducted in referral centres at biosafety level 4, but based on the severity of clinical symptoms, basic laboratories might be required to execute urgent tests for patients suspected of EVD. The aim of this work was to compare the analytical performances of laboratory tests when Triton X-100, a chemical agent able to inactivate other enveloped viruses, was added to specimens. Results of clinical chemistry, coagulation and haematology parameters on samples before and after the addition of 0.1% (final concentration) of Triton X-100 and 1 h of incubation at room temperature were compared. Overall, results showed very good agreement by all statistical analyses. Triton X-100 at 0.1% did not significantly affect the results for the majority of the analytes tested. Triton X-100 at 0.1% can be used to reduce the biohazard in performing laboratory tests on samples from patients with EVD without affecting clinical decisions.

  1. Perceptions and performance using computer-based testing: One institution's experience.

    PubMed

    Bloom, Timothy J; Rich, Wesley D; Olson, Stephanie M; Adams, Michael L

    2018-02-01

    The purpose of this study was to evaluate student and faculty perceptions of the transition to a required computer-based testing format and to identify any impact of this transition on student exam performance. Separate questionnaires sent to students and faculty asked about perceptions of and problems with computer-based testing. Exam results from program-required courses for two years prior to and two years following the adoption of computer-based testing were compared to determine if this testing format impacted student performance. Responses to Likert-type questions about perceived ease of use showed no difference between students with one and three semesters experience with computer-based testing. Of 223 student-reported problems, 23% related to faculty training with the testing software. Students most commonly reported improved feedback (46% of responses) and ease of exam-taking (17% of responses) as benefits to computer-based testing. Faculty-reported difficulties were most commonly related to problems with student computers during an exam (38% of responses) while the most commonly identified benefit was collecting assessment data (32% of responses). Neither faculty nor students perceived an impact on exam performance due to computer-based testing. An analysis of exam grades confirmed there was no consistent performance difference between the paper and computer-based formats. Both faculty and students rapidly adapted to using computer-based testing. There was no evidence that switching to computer-based testing had any impact on student exam performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. An Acute Bout of Self-Myofascial Release in the Form of Foam Rolling Improves Performance Testing

    PubMed Central

    PEACOCK, COREY A.; KREIN, DARREN D.; SILVER, TOBIN A.; SANDERS, GABRIEL J.; VON CARLOWITZ, KYLE-PATRICK A.

    2014-01-01

    Recent developments in the strength and conditioning field have shown the incorporation of foam rolling self-myofascial release in adjunct with a dynamic warm-up. This is thought to improve overall training performance; however, minimal research exists supporting this theory. Therefore, determining if an acute bout of foam rolling self-myofascial release in addition to a dynamic warm-up could influence performance is of importance. In order to do so, eleven athletically trained male subjects participated in a two condition, counterbalanced, crossover within-subjects study comparing two particular warm-up routines. The two warm-up routines compared were a total-body dynamic warm-up (DYN) and a total-body dynamic warm-up in adjunct with a self-myofascial release, total-body foam rolling session (SMR). Following each warm-up condition, subjects performed tests of flexibility, power, agility, strength, and speed. Paired samples T-tests were utilized to determine if there were any significant differences in test results between conditions (DYN vs. SMR). The data indicated that SMR was effective at improving power, agility, strength, and speed when compared to DYN (P ≤ 0.024). A warm-up routine consisting of both a dynamic warm-up and a self-myofascial release, total-body foam rolling session resulted in overall improvements in athletic performance testing. PMID:27182404

  3. 49 CFR 563.10 - Crash test performance and survivability.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 6 2011-10-01 2011-10-01 false Crash test performance and survivability. 563.10 Section 563.10 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION EVENT DATA RECORDERS § 563.10 Crash test performance and survivability. (a) Each...

  4. The effect of poly ethylene glycol additive on the characteristics and performance of cellulose acetate ultrafiltration membrane for removal of Cr(III) from aqueous solution

    NASA Astrophysics Data System (ADS)

    Mulyati, S.; Aprilia, S.; Safiah; Syawaliah; Armando, M. A.; Mawardi, H.

    2018-05-01

    The effect of polyethylene glycol (PEG) additive on the characteristics and performance of the cellulose acetate ultrafiltration membrane to chromium metal removal has been studied using some variation of concentration in the casting solution. The concentration of cellulose acetate polymer was 17.5%, whereas the variations of PEG concentration were regulated at 0, 2.5, 5, 7.5 and 10% by weight. Dimethyl formamide (DMF) was used as a solvent. Pure water flux, membrane morphology test, functional group analysis, and molecular weight cut off (MWCO) were investigated to characterize of the prepared membranes. Membrane performance was tested against Cr(III) metal removal. The results confirmed that the pure water flux improved with the increasing of additive concentration. The maximum improvement occurred at membrane with modification using 7.5% PEG. At this PEG concentration, the pure water flux elevated from 49.5 L/m2.h to 62.2 L/m2.h. The addition of PEG successfully improved the membrane flux because the role PEG plays as a pore-forming agent. Membrane with addition of 7.5% PEG showcased rejection result for chromium metal of 31.89%. This value is lower than that of pure CA membrane which rejection value against Cr(III) metal amounted to 35.72%.

  5. Motivation and performance in physical education: an experimental test.

    PubMed

    Moreno, Juan A; González-Cutre, David; Martín-Albo, José; Cervelló, Eduardo

    2010-01-01

    The purpose of this study was to analyse, experimentally, the relationships between motivation and performance in a lateral movement test in physical education. The study group consisted of 363 students (227 boys and 136 girls), aged between 12 and 16, who were randomly divided into three groups: an experimental group in which an incremental ability belief was induced, another experimental group in which an entity ability belief was induced, and a control group where there was no intervention. Measurements were made of situational intrinsic motivation, perceived competence in executing the task and performance. The results revealed that the incremental group reported higher scores on the situational intrinsic motivation scale. The entity group demonstrated better performance in the first test attempt than the incremental group but, in the second attempt, the performance was similar in the different groups. Perhaps the initial differences in performance disappeared because the incremental group counted on improving in the second attempt. These results are discussed in relation to the intensity with which the teacher conveys information relating to incremental ability belief of the pupil to increase intrinsic motivation and performance. Key pointsThe incremental group showed more situational intrinsic motivation.The entity group showed higher performance in the first test attempt, but significant differences disappeared in the second attempt.It seems that this incremental belief and greater intrinsic motivation made the students trust they would improve their performance in the second attempt at the lateral movement test.

  6. Phase II test plan for the evaluation of the performance of container filling systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BOGER, R.M.

    The PHMC will provide tank wastes for final treatment by BNFL from Hanford's waste tanks. Concerns about the ability for ''grab'' sampling to provide large volumes of representative waste samples has led to the development of a nested, fixed-depth sampling system. Preferred concepts for filling sample containers that meet RCRA organic sample criteria were identified by a PHMC Decision Board. These systems will replace the needle based sampling ''T'' that is currently on the sampling system. This test plan document identifies cold tests with simulants that will demonstrate the preferred bottle filling concepts abilities to provide representative waste samples andmore » will meet RCRA criteria. Additional tests are identified that evaluate the potential for cross-contamination between samples and the ability for the system to decontaminate surfaces which have contacted tank wastes. These tests will be performed with kaolid/water and sand/water slurry simulants in the test rig that was used by AEAT to complete Phase 1 tests in FY 1999.« less

  7. 42 CFR 493.15 - Laboratories performing waived tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Pose no reasonable risk of harm to the patient if the test is performed incorrectly. (c) Certificate of... by single analyte instruments with self-contained or component features to perform specimen/reagent...

  8. 42 CFR 493.15 - Laboratories performing waived tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Pose no reasonable risk of harm to the patient if the test is performed incorrectly. (c) Certificate of... by single analyte instruments with self-contained or component features to perform specimen/reagent...

  9. 42 CFR 493.15 - Laboratories performing waived tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Pose no reasonable risk of harm to the patient if the test is performed incorrectly. (c) Certificate of... by single analyte instruments with self-contained or component features to perform specimen/reagent...

  10. Item Specifications, Science Grade 8. Blue Prints for Testing Minimum Performance Test.

    ERIC Educational Resources Information Center

    Arkansas State Dept. of Education, Little Rock.

    These item specifications were developed as a part of the Arkansas "Minimum Performance Testing Program" (MPT). There is one item specification for each instructional objective included in the MPT. The purpose of an item specification is to provide an overview of the general content and format of test items used to measure an…

  11. Item Specifications, Science Grade 6. Blue Prints for Testing Minimum Performance Test.

    ERIC Educational Resources Information Center

    Arkansas State Dept. of Education, Little Rock.

    These item specifications were developed as a part of the Arkansas "Minimum Performance Testing Program" (MPT). There is one item specification for each instructional objective included in the MPT. The purpose of an item specification is to provide an overview of the general content and format of test items used to measure an…

  12. Measuring Several Aspects of Attention in One Test: The Factor Structure of Conners's Continuous Performance Test

    ERIC Educational Resources Information Center

    Egeland, Jens; Kovalik-Gran, Iwona

    2010-01-01

    Objective: Continuous performance tests are known to typically measure sustained attention but usually also yield parameters that potentially measure other subprocesses of attention. The aim of the present study was to test the factor structure of the Conners's Continuous Performance Test (CCPT) in a heterogeneous clinical sample consisting of…

  13. Integrated Performance Testing Workshop, Modules 6 - 11

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leach, Janice; Torres, Teresa M.

    These modules cover performance testing of: Interior Detection Systems; Access Controls; Exterior Detection Systems; Video Assessment Systems; SNM / Contraband Detection Systems; Access Delay Elements

  14. New solutions to the constant-head test performed at a partially penetrating well

    NASA Astrophysics Data System (ADS)

    Chang, Y. C.; Yeh, H. D.

    2009-05-01

    SummaryThe mathematical model describing the aquifer response to a constant-head test performed at a fully penetrating well can be easily solved by the conventional integral transform technique. In addition, the Dirichlet-type condition should be chosen as the boundary condition along the rim of wellbore for such a test well. However, the boundary condition for a test well with partial penetration must be considered as a mixed-type condition. Generally, the Dirichlet condition is prescribed along the well screen and the Neumann type no-flow condition is specified over the unscreened part of the test well. The model for such a mixed boundary problem in a confined aquifer system of infinite radial extent and finite vertical extent is solved by the dual series equations and perturbation method. This approach provides analytical results for the drawdown in the partially penetrating well and the well discharge along the screen. The semi-analytical solutions are particularly useful for the practical applications from the computational point of view.

  15. Propfan test assessment testbed aircraft stability and control/performance 1/9-scale wind tunnel tests

    NASA Technical Reports Server (NTRS)

    Little, B. H., Jr.; Tomlin, K. H.; Aljabri, A. S.; Mason, C. A.

    1988-01-01

    One-ninth scale wind tunnel model tests of the Propfan Test Assessment (PTA) aircraft were performed in three different NASA facilities. Wing and propfan nacelle static pressures, model forces and moments, and flow field at the propfan plane were measured in these tests. Tests started in June 1985 and were completed in January 1987. These data were needed to assure PTA safety of flight, predict PTA performance, and validate analytical codes that will be used to predict flow fields in which the propfan will operate.

  16. Adolescents' Interest and Performances in Aerobic Fitness Testing

    ERIC Educational Resources Information Center

    Zhu, Xihe; Chen, Senlin; Parrott, James

    2014-01-01

    This study examined adolescents' interest in aerobic fitness testing and its relation to the test performances. Adolescents (N = 356) from three middle schools participated in the study. The participants took two aerobic fitness tests: the Progressive Aerobic Cardiovascular Endurance Run (PACER) and One-Mile Run (1MR) with a two-day interval, and…

  17. Effect of Ag Addition on the Electrochemical Performance of Cu10Al in Artificial Saliva

    PubMed Central

    Salgado-Salgado, R. J.; Sotelo-Mazon, O.; Rodriguez-Diaz, R. A.; Salinas-Solano, G.

    2016-01-01

    In this work we proposed to evaluate the corrosion resistance of four different alloys by electrochemical techniques, a binary alloy Cu10Al, and three ternary alloys Cu10Al-xAg (x = 5, 10, and 15 wt.%) to be used like biomaterials in dental application. Biomaterials proposed were tested in artificial saliva at 37°C for 48 h. In addition, pure metals Cu, Al, Ag, and Ti as reference materials were evaluated. In general the short time tests indicated that the Ag addition increases the corrosion resistance and reduces the extent of localized attack of the binary alloy. Moreover, tests for 48 hours showed that the Ag addition increases the stability of the passive layer, thereby reducing the corrosion rate of the binary alloy. SEM analysis showed that Cu10Al alloy was preferably corroded by grain boundaries, and the Ag addition modified the form of attack of the binary alloy. Cu-rich phases reacted with SCN− anions forming a film of CuSCN, and the Ag-rich phase is prone to react with SCN− anions forming AgSCN. Thus, binary and ternary alloys are susceptible to tarnish in the presence of thiocyanate ions. PMID:27660601

  18. 30 CFR 77.102 - Tests for methane; oxygen deficiency; qualified person, additional requirement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Tests for methane; oxygen deficiency; qualified... methane; oxygen deficiency; qualified person, additional requirement. Notwithstanding the provisions of... and oxygen deficiency unless he has demonstrated to the satisfaction of an authorized representative...

  19. 30 CFR 77.102 - Tests for methane; oxygen deficiency; qualified person, additional requirement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Tests for methane; oxygen deficiency; qualified... methane; oxygen deficiency; qualified person, additional requirement. Notwithstanding the provisions of... and oxygen deficiency unless he has demonstrated to the satisfaction of an authorized representative...

  20. 30 CFR 77.102 - Tests for methane; oxygen deficiency; qualified person, additional requirement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Tests for methane; oxygen deficiency; qualified... methane; oxygen deficiency; qualified person, additional requirement. Notwithstanding the provisions of... and oxygen deficiency unless he has demonstrated to the satisfaction of an authorized representative...

  1. 30 CFR 77.102 - Tests for methane; oxygen deficiency; qualified person, additional requirement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Tests for methane; oxygen deficiency; qualified... methane; oxygen deficiency; qualified person, additional requirement. Notwithstanding the provisions of... and oxygen deficiency unless he has demonstrated to the satisfaction of an authorized representative...

  2. 76 FR 5319 - Regulation of Fuel and Fuel Additives: Alternative Test Method for Olefins in Gasoline

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-31

    ... Regulation of Fuel and Fuel Additives: Alternative Test Method for Olefins in Gasoline AGENCY: Environmental... proposing to allow refiners and laboratories to use an alternative test method for olefin content in... test method for compliance measurement while maintaining environmental benefits achieved from our fuels...

  3. Flight test of takeoff performance monitoring system

    NASA Technical Reports Server (NTRS)

    Middleton, David B.; Srivatsan, Raghavachari; Person, Lee H., Jr.

    1994-01-01

    The Takeoff Performance Monitoring System (TOPMS) is a computer software and hardware graphics system that visually displays current runway position, acceleration performance, engine status, and other situation advisory information to aid pilots in their decision to continue or to abort a takeoff. The system was developed at the Langley Research Center using the fixed-base Transport Systems Research Vehicle (TSRV) simulator. (The TSRV is a highly modified Boeing 737-100 research airplane.) Several versions of the TOPMS displays were evaluated on the TSRV B-737 simulator by more than 40 research, United States Air Force, airline and industry and pilots who rated the system satisfactory and recommended further development and testing. In this study, the TOPMS was flight tested on the TSRV. A total of 55 takeoff and 30 abort situations were investigated at 5 airfields. TOPMS displays were observed on the navigation display screen in the TSRV research flight deck during various nominal and off-nominal situations, including normal takeoffs; reduced-throttle takeoffs; induced-acceleration deficiencies; simulated-engine failures; and several gross-weight, runway-geometry, runway-surface, and ambient conditions. All tests were performed on dry runways. The TOPMS software executed accurately during the flight tests and the displays correctly depicted the various test conditions. Evaluation pilots found the displays easy to monitor and understand. The algorithm provides pretakeoff predictions of the nominal distances that are needed to accelerate the airplane to takeoff speed and to brake it to a stop; these predictions agreed reasonably well with corresponding values measured during several fully executed and aborted takeoffs. The TOPMS is operational and has been retained on the TSRV for general use and demonstration.

  4. Exploration Mission Particulate Matter Filtration Technology Performance Testing in a Simulated Spacecraft Cabin Ventilation System

    NASA Technical Reports Server (NTRS)

    Agui, Juan H.; Vijayakumar, R.; Perry, Jay L.; Frederick, Kenneth R.; Mccormick, Robert M.

    2017-01-01

    Human deep space exploration missions will require advances in long-life, low maintenance airborne particulate matter filtration technology. As one of the National Aeronautics and Space Administrations (NASA) developments in this area, a prototype of a new regenerable, multi-stage particulate matter filtration technology was tested in an International Space Station (ISS) module simulation facility. As previously reported, the key features of the filter system include inertial and media filtration with regeneration and in-place media replacement techniques. The testing facility can simulate aspects of the cabin environment aboard the ISS and contains flight-like cabin ventilation system components. The filtration technology test article was installed at the inlet of the central ventilation system duct and instrumented to provide performance data under nominal flow conditions. In-place regeneration operations were also evaluated. The real-time data included pressure drop across the filter stages, process air flow rate, ambient pressure, humidity and temperature. In addition, two video cameras positioned at the filtration technology test articles inlet and outlet were used to capture the mechanical performance of the filter media indexing operation under varying air flow rates. Recent test results are presented and future design recommendations are discussed.

  5. 47 CFR 76.1704 - Proof-of-performance test data.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Proof-of-performance test data. 76.1704 Section 76.1704 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Documents to be Maintained for Inspection § 76.1704 Proof-of-performance test data. (a) The proof of...

  6. 47 CFR 76.1704 - Proof-of-performance test data.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Proof-of-performance test data. 76.1704 Section 76.1704 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Documents to be Maintained for Inspection § 76.1704 Proof-of-performance test data. (a) The proof of...

  7. Police arrest and self-defence skills: performance under anxiety of officers with and without additional experience in martial arts.

    PubMed

    Renden, Peter G; Landman, Annemarie; Savelsbergh, Geert J P; Oudejans, Raôul R D

    2015-01-01

    We investigated whether officers with additional martial arts training experience performed better in arrest and self-defence scenarios under low and high anxiety and were better able to maintain performance under high anxiety than officers who just rely on regular police training. We were especially interested to find out whether training once a week would already lead to better performance under high anxiety. Officers with additional experience in kickboxing or karate/jiu-jitsu (training several times per week), or krav maga (training once a week) and officers with no additional experience performed several arrest and self-defence skills under low and high anxiety. Results showed that officers with additional experience (also those who trained once a week) performed better under high anxiety than officers with no additional experience. Still, the additional experience did not prevent these participants from performing worse under high anxiety compared to low anxiety. Implications for training are discussed. Practitioner summary: Dutch police officers train their arrest and self-defence skills only four to six hours per year. Our results indicate that doing an additional martial arts training once a week may lead to better performance under anxiety, although it cannot prevent that performance decreases under high anxiety compared to low anxiety.

  8. Polynomials to model the growth of young bulls in performance tests.

    PubMed

    Scalez, D C B; Fragomeni, B O; Passafaro, T L; Pereira, I G; Toral, F L B

    2014-03-01

    The use of polynomial functions to describe the average growth trajectory and covariance functions of Nellore and MA (21/32 Charolais+11/32 Nellore) young bulls in performance tests was studied. The average growth trajectories and additive genetic and permanent environmental covariance functions were fit with Legendre (linear through quintic) and quadratic B-spline (with two to four intervals) polynomials. In general, the Legendre and quadratic B-spline models that included more covariance parameters provided a better fit with the data. When comparing models with the same number of parameters, the quadratic B-spline provided a better fit than the Legendre polynomials. The quadratic B-spline with four intervals provided the best fit for the Nellore and MA groups. The fitting of random regression models with different types of polynomials (Legendre polynomials or B-spline) affected neither the genetic parameters estimates nor the ranking of the Nellore young bulls. However, fitting different type of polynomials affected the genetic parameters estimates and the ranking of the MA young bulls. Parsimonious Legendre or quadratic B-spline models could be used for genetic evaluation of body weight of Nellore young bulls in performance tests, whereas these parsimonious models were less efficient for animals of the MA genetic group owing to limited data at the extreme ages.

  9. 14 CFR 27.927 - Additional tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... controlled by the pilot under normal operating conditions (such as where the primary engine power control is accomplished through the flight control), the following test must be made: (1) Under conditions associated with... the torque must be absorbed by the rotors to be installed, except that other ground or flight test...

  10. 14 CFR 27.927 - Additional tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... controlled by the pilot under normal operating conditions (such as where the primary engine power control is accomplished through the flight control), the following test must be made: (1) Under conditions associated with... the torque must be absorbed by the rotors to be installed, except that other ground or flight test...

  11. Microstructural Modification of Sn-0.7Cu Solder Alloys by Fe/Bi-Addition for Achieving High Mechanical Performance

    NASA Astrophysics Data System (ADS)

    Ali, Bakhtiar; Sabri, Mohd Faizul Mohd; Said, Suhana Mohd; Mahdavifard, Mohammad Hossein; Sukiman, Nazatul Liana; Jauhari, Iswadi

    2017-08-01

    In this work, we studied the Fe/Bi-bearing tin-copper (Sn-0.7Cu) solders for their microstructural and mechanical properties. The microstructure was studied using field emission scanning electron microscopy (FESEM) with a backscattered electron (BSE) detector, x-ray diffraction (XRD) analysis, and energy-dispersive x-ray spectroscopy (EDX). The microstructure study showed that Fe forms very few FeSn2 intermetallic compounds (IMCs) and does not significantly alter the microstructure of Sn-0.7Cu, whereas Bi controls the size of inter-dendritic regions containing Cu6Sn5 and Ag3Sn IMCs of the alloy, as well as significantly refines its primary β-Sn dendrites. Moreover, Bi atoms dissolve in β-Sn matrix, which in turn strengthen the solder by the Bi solid solution strengthening mechanism. Such microstructural modification leads to significant improvements in various mechanical properties of the alloy, including shear strength, impact toughness, and hardness values. Shear tests were performed with a 0.25 mm/min shear speed. The results showed that shear strength improves from 16.57 MPa to 38.36 MPa with the addition of Fe/Bi to Sn-0.7Cu, raising by about 130%. The energy absorbed during impact tests was measured for samples with the help of a Charpy impact testing machine with a 5.4 m/s impact speed. The results revealed that the addition of Fe/Bi to Sn-0.7Cu improves its impact absorbed energy by over 35%, increasing it from 7.5 J to 10.3 J. Vickers hardness tests were carried out for the test samples with a 245.2 mN applied load and 10 s dwell time. The results showed that the hardness number improves from 9.89 to 24.13 with Fe/Bi to Sn-0.7Cu, increasing by about 140%.

  12. [The Additional Role of Symptom-Reflux Association Analysis of Diagnosis of Gastroesophageal Reflux Disease Using Bravo Capsule pH Test].

    PubMed

    Jung, Kyoungwon; Park, Moo In; Park, Seun Ja; Moon, Won; Kim, Sung Eun; Kim, Jae Hyun

    2017-10-25

    Since the development of ambulatory esophageal pH monitoring test to diagnose gastroesophageal reflux disease (GERD), several parameters have been introduced. The aim of this study was to assess whether using the symptom index (SI), symptom sensitivity index (SSI), and symptom association probability (SAP), in addition to the DeMeester score (DS), would be useful for interpreting the Bravo pH monitoring test. A retrospective study, which included 68 patients with reflux symptoms refractory to proton pump inhibitor (PPI) therapy who underwent a Bravo capsule pH test between October 2006 and May 2015, was carried out. Acid reflux parameters and symptom reflux association parameters were analyzed. The median percent time of total pH<4 and DS were 2.90% (interquartile range [IQR] 1.13-6.03%) and 11.10 (IQR 4.90-22.80), respectively. According to the analysis of the day-to-day variation in percent time of total pH<4 (r=0.724) and DS (r=0.537), there was a significant correlation between Day 1 and Day 2. The positive rate of Bravo test according to DS was 27 (39.7%). Although thirty patients experienced symptoms during the test, there were no significant differences of reflux parameters compared with other patients. In the symptom group, 7 patients (23.3%) were identified as having negative DS and an abnormal symptom-related index. There were no significant test-related complications. In addition to the analysis of traditional acid parameters of the Bravo capsule pH test, diagnosis of GERD, including reflux hypersensitivity, can be improved by performing an analysis of the symptom-reflux association and of the day-to-day variation.

  13. 21 CFR 660.26 - Specificity tests and avidity tests.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 7 2013-04-01 2013-04-01 false Specificity tests and avidity tests. 660.26... (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.26 Specificity tests and avidity tests. Specificity and avidity tests shall be performed...

  14. Performance Testing of Yardney Li-Ion Cells and Batteries in Support of Future NASA Missions

    NASA Technical Reports Server (NTRS)

    Smart, M. C.; Ratnakumar, B. V.; Whitcanack, L. D.; Puglia, F. J.; Santee, S.; Gitzendanner, R.

    2009-01-01

    NASA requires lightweight rechargeable batteries for future missions to Mars and the outer planets that are capable of operating over a wide range of temperatures, with high specific energy and energy densities. Due to the attractive performance characteristics, Li-ion batteries have been identified as the battery chemistry of choice for a number of future applications. For example, JPL is planning to launch another unmanned rover mission to the planet Mars. This mission, referred to as the Mars Science Laboratory (MSL), will involve the use of a rover that is much larger than the previously developed Spirit and Opportunity Rovers for the 2003 Mars Exploration Rover (MER) mission, that are currently still in operation on the surface of the planet after more than five years. Part of the reason that the MER rovers have operated so successfully, far exceeding the required mission duration of 90 sols, is that they possess robust Li-ion batteries, manufactured by Yardney Technical Products, which have demonstrated excellent life characteristics. Given the excellent performance characteristics displayed, similar Li-ion batteries have been projected to successfully meet the mission requirements of the up-coming MSL mission. In addition to future missions to Mars, Li-ion technology is attractive for a number of other future NASA applications which require high specific energy, rechargeable batteries. To ascertain the viability of using Li-ion batteries for these applications, a number of performance validation tests have been performed on both Yardney cells and batteries of various sizes. These tests include mission simulation tests, charge and discharge rate characterization testing, cycle life testing under various conditions, and storage testing.

  15. A Test That Isn't Torture: A Field-Tested Performance-Based Assessment

    ERIC Educational Resources Information Center

    Eastburn, Mark

    2006-01-01

    This article discusses the author's use of a performance-based evaluation in his fifth grade Spanish class in a K-5 public elementary school located in Princeton, New Jersey. The author realized the need to break the old testing paradigm and discover a new way of demonstrating student language acquisition since the traditional tests did not seem…

  16. 47 CFR 76.1704 - Proof-of-performance test data.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...-performance test data. (a) The proof of performance tests required by § 76.601 shall be maintained on file at... subscribers, subject to the requirements of § 76.601(d). Note to § 76.1704: If a signal leakage log is being... log must be retained for the period specified in § 76.601(d). ...

  17. 47 CFR 76.1704 - Proof-of-performance test data.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-performance test data. (a) The proof of performance tests required by § 76.601 shall be maintained on file at... subscribers, subject to the requirements of § 76.601(d). Note to § 76.1704: If a signal leakage log is being... log must be retained for the period specified in § 76.601(d). ...

  18. Enhanced CO2 adsorptive performance of PEI/SBA-15 adsorbent using phosphate ester based surfactants as additives.

    PubMed

    Cheng, Dandan; Liu, Yue; Wang, Haiqiang; Weng, Xiaole; Wu, Zhongbiao

    2015-12-01

    In this study, a series of polyetherimide/SBA-15: 2-D hexagonal P6mm, Santa Barbara USA (PEI/SBA-15) adsorbents modified by phosphoric ester based surfactants (including tri(2-ethylhexyl) phosphate (TEP), bis(2-ethylhexyl) phosphate (BEP) and trimethyl phosphonoacetate (TMPA)) were prepared for CO2 adsorption. Experimental results indicated that the addition of TEP and BEP had positive effects on CO2 adsorption capacity over PEI/SBA-15. In particular, the CO2 adsorption amount could be improved by around 20% for 45PEI-5TEP/SBA-15 compared to the additive-free adsorbent. This could be attributed to the decrease of CO2 diffusion resistance in the PEI bulk network due to the interactions between TEP and loaded PEI molecules, which was further confirmed by adsorption kinetics results. In addition, it was also found that the cyclic performance of the TEP-modified adsorbent was better than the surfactant-free one. This could be due to two main reasons, based on the results of in situ DRIFT and TG-DSC tests. First and more importantly, adsorbed CO2 species could be desorbed more rapidly over TEP-modified adsorbent during the thermal desorption process. Furthermore, the enhanced thermal stability after TEP addition ensured lower degradation of amine groups during adsorption/desorption cycles. Copyright © 2015. Published by Elsevier B.V.

  19. Blood pressure and neuropsychological test performance in healthy postmenopausal women.

    PubMed

    Alsumali, Adnan; Mekary, Rania A; Seeger, John; Regestein, Quentin

    2016-06-01

    To study the association between blood pressure and neuropsychological test performance in healthy postmenopausal women. Data from 88 healthy postmenopausal women aged 46-73 years, who were not experiencing hot flashes, and who had participated in a prior drug trial, were analyzed to find whether baseline blood pressure was associated with impaired performance on neuropsychological testing done at 3 follow-up visits separated by 4 weeks. Factor analysis was used to reduce the dimensions of neuropsychological test performance. Mixed linear modeling was used to evaluate the association between baseline blood pressure and repeatedly measured neuropsychological test performance at follow-up in a complete case analysis (n=53). In a sensitivity analysis (n=88), multiple-imputation using the Markov Chain Monte Carlo method was used to account for missing data (blood pressure results) for some visits. The variables recording neuropsychological test performance were reduced to two main factors (Factor 1=selective attention; Factor 2=complex processing). In the complete case analysis, the association between a 20-mmHg increase in diastolic blood pressure and Factor 1 remained statistically significant after adjusting for potential confounders, before adjusting for systolic blood pressure (slope=0.60; 95%CI=0.04,1.16), and after adjusting for systolic blood pressure (slope=0.76; 95%CI=0.06, 1.47). The positive slopes indicated an increase in the time spent performing a given task (i.e., a decrease in neuropsychological test performance). No other significant associations were found between systolic blood pressure and either factor. The results did not materially change after applying the multiple-imputation method. An increase in diastolic blood pressure was associated with a decrease in neuropsychological test performance among older healthy postmenopausal women experiencing hot flashes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Dental Student Study Strategies: Are Self-Testing and Scheduling Related to Academic Performance?

    PubMed

    McAndrew, Maureen; Morrow, Christina S; Atiyeh, Lindsey; Pierre, Gaëlle C

    2016-05-01

    Self-testing, a strategy wherein a student actively engages in creating questions and answers from study materials to assist with studying, has been found to be especially advantageous because it enhances future retrieval of information. Studies have found correlations among students' grade point averages (GPAs), self-testing, and rereading study strategies, as well as the spacing of study sessions over time. The aim of this study was to assess relationships among dental students' study strategies, scheduling of study time, and academic achievement. A 16-item survey requesting information on study habits, study schedules, and GPAs was distributed to 358 second-year dental students at New York University College of Dentistry. Additionally, the survey asked students to report the average number of hours per week they devoted to studying for didactic courses and preparing for hands-on preclinical courses. Of the 358 students, 94 (26%) responded to the survey. The vast majority of the respondents reported utilizing self-testing and rereading study strategies. High performers (with higher GPAs) were more likely to use self-testing, especially with flashcards, and to space their studying over multiple sessions. Lower performing students were more likely to highlight or underline their notes and to mass their study sessions or cram. Longer hours devoted to studying and practicing for simulation courses were associated with stronger performance; lower performers reported spending significantly fewer hours practicing for simulation courses. Half of the dental students surveyed said that they felt their studying would be more productive in the morning, although 84% reported doing most of their studying in the evening or late night. Sound study decisions depend on accurate regulation of ongoing learning and appropriate use and timing of evidence-based study strategies, so these results suggest that dental students may require guidance in these areas.

  1. The Maintenance of Wakefulness Test and driving simulator performance.

    PubMed

    Banks, Siobhan; Catcheside, Peter; Lack, Leon C; Grunstein, Ron R; McEvoy, R Doug

    2005-11-01

    It has been suggested that the Maintenance of Wakefulness Test (MWT) may be clinically useful to assess fitness to drive, yet little is known about the actual relationship between sleep latency and driving performance. This study examined the ability of 2 MWT trials to predict driving-simulator performance in healthy individuals. Experimental. NA. Twenty healthy volunteers (mean age 22.8 years; 9 men). NA. The MWT and driving-simulator performance were examined under 2 conditions-partial sleep deprivation and a combination of partial sleep deprivation and alcohol consumption. Each subject was studied a week apart, with the order randomly assigned. Subjects completed a nighttime 70-minute AusEd driving simulation task and two 40-minute MWT trials, 1 before (MWT1) and 1 after (MWT2) the driving task. In the sleep-deprived condition, the MWT1 sleep latency was inversely correlated with braking reaction time. During the partial sleep deprivation and alcohol condition, the number of microsleeps during the driving task, steering deviation, braking reaction time, and crashes all negatively correlated with the MWT1 sleep latency. Additionally, construction of a receiver-operator characteristic curve revealed that MWT1 sleep latency in the partial sleep deprivation plus alcohol condition significantly discriminated subjects who had a crash from those who did not. These results indicate that sleep latency on the MWT is a reasonable predictor of driving simulator performance in sleepy, alcohol-impaired, normal subjects. Further research is needed to examine the relationship between daytime MWT results and driving simulator performance in sleepy patients (eg, those with obstructive sleep apnea) and in experimentally sleep-deprived normal subjects.

  2. Field test and simulation evaluation of variable refrigerant flow systems performance

    DOE PAGES

    Lee, Je Hyeon; Im, Piljae; Song, Young-hak

    2017-10-24

    Our study aims to compare the performance of a Variable Refrigerant Flow (VRF) system with a Roof Top Unit, (RTU) and a variable-air-volume (VAV) system through field tests and energy simulations. The field test was conducted in as similar conditions as possible between the two systems, such as the installation and operating environments of heating, the ventilation and air conditioning (HVAC) system, including internal heat gain and outdoor conditions, including buildings to compare the performance of the two systems accurately. A VRF system and RTU were installed at the test building located in Oak Ridge, Tennessee, in the USA. Themore » same internal heat gain was generated at the same operating time of the two systems using lighting, electric heaters, and humidifiers inside the building. The HVAC system was alternately operated between cooling and heating operations to acquire energy performance data and to compare energy usage. Furthermore, an hourly building energy simulation model was developed with regard to the VRF system and RTU, and then the model was calibrated using actual measured data. Then, annual energy consumption of the two systems were compared and analyzed using the calibrated model. Moreover, additional analysis was conducted when the controlled discharge air temperature in the RTU was changed. The field test result showed that when energy consumptions of two systems were compared at the same outdoor conditions, using the weather-normalized model, the VRF system exhibited an energy reduction of approximately 17% during cooling operation and of approximately 74% during heating operations. A comparison on the annual energy consumption using simulations showed that the VRF system reduced energy consumption more than that of the RTU by 60%. Furthermore, when the discharge air temperature in the RTU was controlled according to the outdoor air temperature, energy consumption of the RTU was reduced by 6% in cooling operations and by 18% in heating

  3. Field test and simulation evaluation of variable refrigerant flow systems performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Je Hyeon; Im, Piljae; Song, Young-hak

    Our study aims to compare the performance of a Variable Refrigerant Flow (VRF) system with a Roof Top Unit, (RTU) and a variable-air-volume (VAV) system through field tests and energy simulations. The field test was conducted in as similar conditions as possible between the two systems, such as the installation and operating environments of heating, the ventilation and air conditioning (HVAC) system, including internal heat gain and outdoor conditions, including buildings to compare the performance of the two systems accurately. A VRF system and RTU were installed at the test building located in Oak Ridge, Tennessee, in the USA. Themore » same internal heat gain was generated at the same operating time of the two systems using lighting, electric heaters, and humidifiers inside the building. The HVAC system was alternately operated between cooling and heating operations to acquire energy performance data and to compare energy usage. Furthermore, an hourly building energy simulation model was developed with regard to the VRF system and RTU, and then the model was calibrated using actual measured data. Then, annual energy consumption of the two systems were compared and analyzed using the calibrated model. Moreover, additional analysis was conducted when the controlled discharge air temperature in the RTU was changed. The field test result showed that when energy consumptions of two systems were compared at the same outdoor conditions, using the weather-normalized model, the VRF system exhibited an energy reduction of approximately 17% during cooling operation and of approximately 74% during heating operations. A comparison on the annual energy consumption using simulations showed that the VRF system reduced energy consumption more than that of the RTU by 60%. Furthermore, when the discharge air temperature in the RTU was controlled according to the outdoor air temperature, energy consumption of the RTU was reduced by 6% in cooling operations and by 18% in heating

  4. Threshold values of physical performance tests for locomotive syndrome.

    PubMed

    Muramoto, Akio; Imagama, Shiro; Ito, Zenya; Hirano, Kenichi; Tauchi, Ryoji; Ishiguro, Naoki; Hasegawa, Yukiharu

    2013-07-01

    Our previous study determined which physical performance tests were the most useful for evaluating locomotive syndrome. Our current study establishes reference values for these major physical performance tests with regards to diagnosing and assessing risk of locomotive syndrome (LS). We measured timed-up-and-go test, one-leg standing time, back muscle strength, grip strength, 10-m gait time and maximum stride in 406 individuals (167 men, 239 women) between the ages of 60-88 years (mean 68.8 ± 6.7 years) during Yakumo Study 2011-12. The LS was defined as having a score of >16 points on the 25-Question Geriatric Locomotive Function Scale (GLFS-25). The reference value of each physical test was determined using receiver operating characteristics analysis. Women had a significantly higher prevalence of LS than men did and also scored significantly higher on the GLFS-25: women, 9.2 ± 10.3 pts; men, 6.7 ± 8.0 pts. Both genders in the non-LS group performed significantly better in all physical performance test gender except for back muscle strength in men and grip strength in both genders than those in the LS group, even after adjusting for age. The results of all the physical performance tests correlated significantly with the GLFS-25 scores of both genders even after adjusting for age except for grip strength. Reference values for TUG, one-leg standing time, back muscle strength, 10-m gait time, maximum stride and grip strength in men were 6.7 s, 21 s, 78 kg, 5.5 s and, 119 cm and 34 kg, respectively, and those for women were 7.5 s, 15 s, 40 kg, 6.2 s, 104 cm, and 22 kg, respectively. We established reference values for major physical performance tests used when assessing locomotive syndrome as defined by the GLFS-25. Our results can be used to characterize physical function and to help tailor an anti-LS training program for each individual.

  5. Post-Flight Analysis of the Guidance, Navigation, and Control Performance During Orion Exploration Flight Test 1

    NASA Technical Reports Server (NTRS)

    Barth, Andrew; Mamich, Harvey; Hoelscher, Brian

    2015-01-01

    The first test flight of the Orion Multi-Purpose Crew Vehicle presented additional challenges for guidance, navigation and control as compared to a typical re-entry from the International Space Station or other Low Earth Orbit. An elevated re-entry velocity and steeper flight path angle were chosen to achieve aero-thermal flight test objectives. New IMU's, a GPS receiver, and baro altimeters were flight qualified to provide the redundant navigation needed for human space flight. The guidance and control systems must manage the vehicle lift vector in order to deliver the vehicle to a precision, coastal, water landing, while operating within aerodynamic load, reaction control system, and propellant constraints. Extensive pre-flight six degree-of-freedom analysis was performed that showed mission success for the nominal mission as well as in the presence of sensor and effector failures. Post-flight reconstruction analysis of the test flight is presented in this paper to show whether that all performance metrics were met and establish how well the pre-flight analysis predicted the in-flight performance.

  6. 40 CFR 63.1333 - Additional requirements for performance testing.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... paragraphs (b)(1) and (b)(2) of this section. ER19JN00.041 Where: ERMBS = Emission rate of organic HAP or TOC from continuous process vents, kg/Mg product. Ei = Emission rate of organic HAP or TOC from continuous... hours in a year for control device j. Ei=Mass rate of TOC or total organic HAP at the inlet of control...

  7. 40 CFR 63.1437 - Additional requirements for performance testing.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... gas being combusted, using the techniques specified in § 63.11(b)(6) of the General Provisions; and (3... National Emission Standards for Hazardous Air Pollutant Emissions for Polyether Polyols Production § 63..., using the techniques specified in paragraphs (c)(1) through (3) of this section, that compliance...

  8. The Face-Symbol Test and the Symbol-Digit Test are not reliable surrogates for the Paced Auditory Serial Addition Test in multiple sclerosis.

    PubMed

    Williams, J; O'Rourke, K; Hutchinson, M; Tubridy, N

    2006-10-01

    The Paced Auditory Serial Addition Test (PASAT) is the chosen task for cognitive assessment in the multiple sclerosis functional composite (MSFC) and a widely used task in neuropsychological studies of people with multiple sclerosis (MS), but is unpopular with patients. The Face-Symbol Test (FST) and Symbol-Digit Tests (SDT) are alternative methods of cognitive testing in MS, which are easily administered and patient-friendly. In order to evaluate the potential of the FST as a possible surrogate for the PASAT, we directly compared the FST to the PASAT and the SDT in a cohort of 50 MS patients with varying levels of disability. There was significant correlation between SDT and FST scores (Spearman's rho 0.80, 95% CI 0.66-0.88), R(2) 65%, with moderate inter-test agreement (k =0.52). In contrast, SDT and FST scores were less predictive of PASAT scores. We concluded that neither the FST nor SDT are reliable surrogates for the PASAT.

  9. A Litmus Test for Performance Assessment.

    ERIC Educational Resources Information Center

    Finson, Kevin D.; Beaver, John B.

    1992-01-01

    Presents 10 guidelines for developing performance-based assessment items. Presents a sample activity developed from the guidelines. The activity tests students ability to observe, classify, and infer, using red and blue litmus paper, a pH-range finder, vinegar, ammonia, an unknown solution, distilled water, and paper towels. (PR)

  10. Is there a role of food additives in recurrent aphthous stomatitis? A prospective study with patch testing.

    PubMed

    Gülseren, Duygu; Hapa, Asli; Ersoy-Evans, Sibel; Elçin, Gonca; Karaduman, Ayşen

    2017-03-01

    Recurrent aphthous stomatitis (RAS) is a common disease of the oral mucosa with an unknown etiology. This study aimed to determine if food additives play a role in the etiology of RAS as well as to determine if patch testing can be used to detect which allergens cause RAS. This prospective study included 24 patients with RAS and 22 healthy controls. All the participants underwent patch testing for 23 food additives. In total, 21 (87.5%) RAS patients and 3 (13.6%) controls had positive patch test reactions to ≥1 allergens; the difference in the patch test positivity rate between groups was significant (P < 0.05). The most common allergen that elicited positive patch test results in the patient group was cochineal red (n = 15 [62.5%]), followed by azorubine (n = 11 [45.8%]) and amaranth (n = 6 [25%]). The present findings show that food additives might play a role in the etiology of RAS and that patch testing could be a method for determining the etiology of RAS. © 2016 The International Society of Dermatology.

  11. METHODS FOR IMPROVEMENT OF TRICKLING FILTER PLANT PERFORMANCE. PART II. CHEMICAL ADDITION

    EPA Science Inventory

    An experimental program to explore potential methods for removing phosphorus and generally enhancing trickling filter plant performance was conducted at the Mason Farm Wastewater Treatment Plant, Chapel Hill, North Carolina. Preliminary investigations included jar testing with se...

  12. [Genetic-statistical analysis of environmental and genetic influences on the outcome of the juvenile and breeding performance tests for behaviour traits in Hovawart dogs].

    PubMed

    Boenigk, Katharina; Hamann, Henning; Distl, Ottmar

    2006-01-01

    The objective of the present study was to evaluate the importance of genetic and environmental sources of variation for results of behaviour tests recorded at juvenile and breeding performance tests in the Hovawart dog. For these analyses behaviour test results of 1882 (juvenile evaluation), respectively 929 dogs (breeding performance test) born in 1995 to 2000 had been used. Variance component estimation was performed for the traits appearance, play instinct, hunting affinity, group of people, shoot, acoustical and optical influences and temperament using multivariate linear animal models and Residual Maximum Likelihood (REML). The models included test-year-season, sex, litter size, age and inbreeding coefficient of the animal as fixed effects. Additive genetic effects of the animal, permanent environmental effect of the litter and the effect of the kennel were considered as random factors. The sex of the dog was significant for appearance, play instinct, hunting affinity, acoustical and optical influences of juvenile evaluation and for the traits temperament, play instinct, hunting affinity, acoustical and one of the optical influences of breeding performance test. The age of the dog at test significantly influenced the traits play instinct, hunting affinity and acoustical influences of juvenile evaluation and optical influences and hunting affinity of breeding performance test. All traits with exception of hunting affinity and group of people were significantly affected by the test-year-season. The inbreeding coefficient was significant for appearance of juvenile evaluation and play affinity of breeding performance test. The effect litter size did not influence any of the traits significantly. The estimated heritabilities for the behaviour traits of juvenile and breeding performance test ranged from h2 = 0.01 to h2 = 0.13, respectively h2 = 0.01 to h2 = 0.14, with standard errors of up to 0.03. The additive genetic correlations between most of the traits were

  13. National Unmanned Aerial System Standardized Performance Testing and Rating (NUSTAR)

    NASA Technical Reports Server (NTRS)

    Kopardekar, Parimal

    2016-01-01

    The overall objective of the NUSTAR Capability is to offer standardized tests and scenario conditions to assess performance of the UAS. The following are goals of the NU-STAR: 1. Create a prototype standardized tests and scenarios that vehicles can be tested against. 2. Identify key performance parameters of all UAS and their standardized measurement strategy. 3. Develop standardized performance reporting method (e.g., consumer report style) to assist prospective buyers. 4. Identify key performance metrics that could be used by judged towards overall safety of the UAS and operations. 5. If vehicle certification standard is made by a regulatory agency, the performance of individual UAS could be compared against the minimum requirement (e.g., sense and avoid detection time, stopping distance, kinetic energy, etc.).

  14. 40 CFR 63.1512 - Performance test/compliance demonstration requirements and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... operator must conduct a performance test to measure THC and D/F emissions at the outlet of the control.../decoating kiln. The owner or operator must conduct performance tests to measure emissions of THC, D/F, HCl... operating temperature of each afterburner every 15 minutes during the THC and D/F performance tests; (ii...

  15. 40 CFR 63.1512 - Performance test/compliance demonstration requirements and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... operator must conduct a performance test to measure THC and D/F emissions at the outlet of the control.../decoating kiln. The owner or operator must conduct performance tests to measure emissions of THC, D/F, HCl... operating temperature of each afterburner every 15 minutes during the THC and D/F performance tests; (ii...

  16. Reverse translated and gold standard continuous performance tests predict global cognitive performance in schizophrenia.

    PubMed

    Bismark, Andrew W; Thomas, Michael L; Tarasenko, Melissa; Shiluk, Alexandra L; Rackelmann, Sonia Y; Young, Jared W; Light, Gregory A

    2018-04-12

    Attentional dysfunction contributes to functional impairments in schizophrenia (SZ). Sustained attention is typically assessed via continuous performance tasks (CPTs), though many CPTs have limited cross-species translational validity and place demands on additional cognitive domains. A reverse-translated 5-Choice Continuous Performance Task (5C-CPT) for human testing-originally developed for use in rodents-was designed to minimize demands on perceptual, visual learning, processing speed, or working memory functions. To-date, no studies have validated the 5C-CPT against gold standard attentional measures nor evaluated how 5C-CPT scores relate to cognition in SZ. Here we examined the relationship between the 5C-CPT and the CPT-Identical Pairs (CPT-IP), an established and psychometrically robust measure of vigilance from the MATRICS Consensus Cognitive Battery (MCCB) in a sample of SZ patients (n = 35). Relationships to global and individual subdomains of cognition were also assessed. 5C-CPT and CPT-IP measures of performance (d-prime) were strongly correlated (r = 0.60). In a regression model, the 5C-CPT and CPT-IP collectively accounted for 54% of the total variance in MCCB total scores, and 27.6% of overall cognitive variance was shared between the 5C-CPT and CPT-IP. These results indicate that the reverse translated 5C-CPT and the gold standard CPT-IP index a common attentional construct that also significantly overlaps with variance in general cognitive performance. The use of simple, cross-species validated behavioral indices of attentional/cognitive functioning such as the 5C-CPT could accelerate the development of novel generalized pro-cognitive therapeutics for SZ and related neuropsychiatric disorders.

  17. Gaia challenging performances verification: combination of spacecraft models and test results

    NASA Astrophysics Data System (ADS)

    Ecale, Eric; Faye, Frédéric; Chassat, François

    2016-08-01

    To achieve the ambitious scientific objectives of the Gaia mission, extremely stringent performance requirements have been given to the spacecraft contractor (Airbus Defence and Space). For a set of those key-performance requirements (e.g. end-of-mission parallax, maximum detectable magnitude, maximum sky density or attitude control system stability), this paper describes how they are engineered during the whole spacecraft development process, with a focus on the end-to-end performance verification. As far as possible, performances are usually verified by end-to-end tests onground (i.e. before launch). However, the challenging Gaia requirements are not verifiable by such a strategy, principally because no test facility exists to reproduce the expected flight conditions. The Gaia performance verification strategy is therefore based on a mix between analyses (based on spacecraft models) and tests (used to directly feed the models or to correlate them). Emphasis is placed on how to maximize the test contribution to performance verification while keeping the test feasible within an affordable effort. In particular, the paper highlights the contribution of the Gaia Payload Module Thermal Vacuum test to the performance verification before launch. Eventually, an overview of the in-flight payload calibration and in-flight performance verification is provided.

  18. Accounting for Laminar Run & Trip Drag in Supersonic Cruise Performance Testing

    NASA Technical Reports Server (NTRS)

    Goodsell, Aga M.; Kennelly, Robert A.

    1999-01-01

    An improved laminar run and trip drag correction methodology for supersonic cruise performance testing was derived. This method required more careful analysis of the flow visualization images which revealed delayed transition particularly on the inboard upper surface, even for the largest trip disks. In addition, a new code was developed to estimate the laminar run correction. Once the data were corrected for laminar run, the correct approach to the analysis of the trip drag became evident. Although the data originally appeared confusing, the corrected data are consistent with previous results. Furthermore, the modified approach, which was described in this presentation, extends prior historical work by taking into account the delayed transition caused by the blunt leading edges.

  19. 47 CFR 76.601 - Performance tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 4 2013-10-01 2013-10-01 false Performance tests. 76.601 Section 76.601 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND... standards set forth in § 76.605(a) (3), (4), and (5) shall be made on each of the NTSC or similar video...

  20. Diagnostic performance of the atopy patch test with inhalant allergens.

    PubMed

    Fuiano, N; Diddi, G; Delvecchio, M; Incorvaia, C

    2015-01-01

    This study evaluated the diagnostic performance of the atopy patch test (APT) compared with skin prick testing (SPT) and in vitro IgE measurement in a large group of patients with atopic dermatitis (AD) with or without respiratory symptoms (RS). The study included 521 patients (292 males, 229 females; age, 0.5-18 years; median age, 6 years) with AD and RS with different clinical presentations: current AD, 47 patients (Group A); current AD and RS, 72 patients (Group B), past AD and RS, 69 patients (Group C); and RS only, 280 patients (Group D). Fifty-three healthy individuals served as controls. All participants underwent the APT, SPT, and CAP/RAST with the most common inhalant allergens. The presence of a control group allowed calculation of specificity and positive and negative predictive values. A significant difference was found for a positive APT versus both SPT and CAP/RAST (P < .0001) but not for SPT versus CAP/RAST. The differences for APT were significant in all group comparisons except group B vs C and group C vs D. In the control group, the APT was positive in 2% of cases (specificity of 96.2%), SPT was positive in 6% of cases (specificity of 88.4%), and CAP/RAST was positive in 4% of cases (specificity of 92.5%). In young patients sensitized to inhalant allergens with AD in addition to RS, the APT has a superior diagnostic performance to SPT and in vitro IgE measurement.

  1. Validation of the LacTek test applied to spiked extracts of tissue samples: determination of performance characteristics.

    PubMed

    Mitchell, J M; Yee, A J; McNab, W B; Griffiths, M W; McEwen, S A

    1999-01-01

    LacTek tests are competitive enzyme-linked immunosorbent assays intended for rapid detection of antimicrobial residues in bovine milk. In this study, the LacTek test protocol was modified for use with extracts of bovine tissue to detect beta-lactam, tetracycline, and sulfamethazine residues. Test performance characteristics--precision, accuracy, ruggedness, practicability, and analytical specificity and sensitivity--were investigated. Results suggest that LacTek tests can be easily adapted to detect antimicrobial residues in extracts of lean ground beef. However, positive samples may not contain residues at violative concentrations (i.e., Canadian maximum residue limits), and therefore, additional analysis would be required for final confirmation and quantitation (e.g., chromatography).

  2. Differential effects of scopolamine and amphetamine on microcomputer-based performance tests

    NASA Technical Reports Server (NTRS)

    Kennedy, Robert S.; Odenheimer, Robert C.; Baltzley, Dennis R.; Dunlap, William P.; Wood, Charles D.

    1990-01-01

    The effects of four weekly treatments with scopolamine (1.0 mg) and d-amphetamine (10 mg), separately or in combination, on human performance were investigated in 16 subjects undergoing nine performance tests from a menu of microcomputer-based tests administered after the treatment. It was d-amphetamine treatment that enhanced the results of motor and perceptual speed tests, while scopolamine had no effect on these tests. Two of the five cognitive tests showed reductions with scopolamine. The effects of scopolamine in this and other studies are considered in terms of a model which implies that the magnitude of the performance deficit depends on the performance type and the dosage level of the drug.

  3. Improvement of fruit and vegetable waste anaerobic digestion performance and stability with co-substrates addition.

    PubMed

    Bouallagui, H; Lahdheb, H; Ben Romdan, E; Rachdi, B; Hamdi, M

    2009-04-01

    The effect of fish waste (FW), abattoir wastewater (AW) and waste activated sludge (WAS) addition as co-substrates on the fruit and vegetable waste (FVW) anaerobic digestion performance was investigated under mesophilic conditions using four anaerobic sequencing batch reactors (ASBR) with the aim of finding the better co-substrate for the enhanced performance of co-digestion. The reactors were operated at an organic loading rate of 2.46-2.51 g volatile solids (VS)l(-1)d(-1), of which approximately 90% were from FVW, and a hydraulic retention time of 10 days. It was observed that AW and WAS additions with a ratio of 10% VS enhanced biogas yield by 51.5% and 43.8% and total volatile solids removal by 10% and 11.7%, respectively. However FW addition led to improvement of the process stability, as indicated by the low VFAs/Alkalinity ratio of 0.28, and permitted anaerobic digestion of FVW without chemical alkali addition. Despite a considerable decrease in the C/N ratio from 34.2 to 27.6, the addition of FW slightly improved the gas production yield (8.1%) compared to anaerobic digestion of FVW alone. A C/N ratio between 22 and 25 seemed to be better for anaerobic co-digestion of FVW with its co-substrates. The most significant factor for enhanced FVW digestion performance was the improved organic nitrogen content provided by the additional wastes. Consequently, the occurrence of an imbalance between the different groups of anaerobic bacteria which may take place in unstable anaerobic digestion of FVW could be prevented.

  4. 40 CFR 63.865 - Performance test requirements and test methods.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the chemical recovery system at the kraft or soda pulp mill, kg/Mg (lb/ton) of black liquor solids... the performance test, megagrams per day (Mg/d) (tons per day (ton/d)) of black liquor solids fired. ER1ref, SDT = reference emission rate of 0.10 kg/Mg (0.20 lb/ton) of black liquor solids fired for...

  5. 40 CFR 63.865 - Performance test requirements and test methods.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the chemical recovery system at the kraft or soda pulp mill, kg/Mg (lb/ton) of black liquor solids... the performance test, megagrams per day (Mg/d) (tons per day (ton/d)) of black liquor solids fired. ER1ref, SDT = reference emission rate of 0.10 kg/Mg (0.20 lb/ton) of black liquor solids fired for...

  6. Amphetamine improves mouse and human attention in the 5-choice continuous performance test.

    PubMed

    MacQueen, David A; Minassian, Arpi; Kenton, Johnny A; Geyer, Mark A; Perry, William; Brigman, Jonathan L; Young, Jared W

    2018-05-31

    Non-medical use of prescription stimulants amongst college students is common, with claims of cognitive and academic benefits. The mechanism, magnitude, and pervasiveness of the cognitive enhancing effects of stimulants in healthy adults remain poorly understood however. The present study determined the effects of dextroamphetamine (D-amp) on the 5-choice continuous performance test (5C-CPT) of attention in healthy young adult humans and mice. A mixed gender sample received placebo (n = 29), 10 (n = 17) or 20 mg D-amp (n = 25) in a double-blind fashion before 5C-CPT testing. In addition, male C57BL/6J mice were trained on a touchscreen adaptation of the 5C-CPT and tested after receiving saline or D-amp (0.1, 0.3, 1.0 mg/kg; n = 8/dose). In humans, D-amp significantly improved 5C-CPT performance. Both doses improved signal detection driven by increased hit rate (reduced omissions). Both doses also improved response accuracy and reduced hit reaction time (HRT) variability. In mice, similar effects (improved signal detection, hit rate, and response accuracy) were observed at the moderate dose (0.3 mg/kg). In contrast to human participants however, no effect on HRT variability was detected in mice, with no effect on HRT in either species. Human 5C-CPT performance was consistent with prior studies and consistent with alternative CPT paradigms. The performance of C57BL/6J mice on the touchscreen 5C-CPT mirrored performance of this strain on 5-hole operant chambers. Importantly, comparable facilitation of attention with D-amp was observed in both species. The 5C-CPT provides a cross-species paradigm by which the cognitive enhancing properties of stimulants and the neural underpinnings of attention can be assessed. Copyright © 2018. Published by Elsevier Ltd.

  7. Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR)

    DTIC Science & Technology

    2008-12-01

    the standard SETCO tires. A blast test of the new SETCO tire is scheduled for the spring of...Washington, DC 20301-2500 Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR) December 2008 Prepared ...2008 to 00-00-2008 4. TITLE AND SUBTITLE Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR) 5a. CONTRACT NUMBER 5b.

  8. Distraction produces over-additive increases in the degree to which alcohol impairs driving performance.

    PubMed

    Van Dyke, Nicholas A; Fillmore, Mark T

    2015-12-01

    Research indicates that alcohol intoxication and increased demands on drivers' attention from distractions (e.g., passengers and cell phones) contribute to poor driving performance and increased rates of traffic accidents and fatalities. The present study examined the separate and combined effects of alcohol and distraction on simulated driving performance at blood alcohol concentrations (BrACs) below the legal driving limit in the USA (i.e., 0.08 %). Fifty healthy adult drivers (36 men and 14 women) were tested in a driving simulator following a 0.65-g/kg dose of alcohol and a placebo. Drivers completed two drive tests: a distracted drive, which included a two-choice detection task, and an undistracted control drive. Multiple indicators of driving performance, such as drive speed, within-lane deviation, steering rate, and lane exceedances were measured. Alcohol and distraction each impaired measures of driving performance. Moreover, the magnitude of alcohol impairment was increased by at least twofold when tested under the distracting versus the undistracted condition. The findings highlight the need for a clearer understanding of how common distractions impact intoxicated drivers, especially at BrACs that are currently legal for driving in the USA.

  9. Cryogenic Thermal Performance Testing of Bulk-Fill and Aerogel Insulation Materials

    NASA Technical Reports Server (NTRS)

    Scholtens, B. E.; Fesmire, J. E.; Sass, J. P.; Augustynowicz, S. D.; Heckle, K. W.

    2007-01-01

    The research testing and demonstration of new bulk-fill materials for cryogenic thermal insulation systems was performed by the Cryogenics Test Laboratory at NASA Kennedy Space Center. Thermal conductivity testing under actual-use cryogenic conditions is a key to understanding the total system performance encompassing engineering, economics, and materials factors. A number of bulk fill insulation materials, including aerogel beads, glass bubbles, and perlite powder, were tested using a new cylindrical cryostat. Boundary temperatures for the liquid nitrogen boil-off method were 293 K and 78 K. Tests were performed as a function of cold vacuum pressure from high vacuum to no vacuum conditions. Results are compared with other complementary test methods in the range of 300 K to 20 K. Various testing techniques are shown to be required to obtain a complete understanding of the operating performance of a material and to provide data for answers to design engineering questions.

  10. Development, evaluation and application of performance-based brake testing technologies field test : executive summary

    DOT National Transportation Integrated Search

    1999-09-01

    This report presents the results of the field test portion of the Development, Evaluation, and Application of Performance-Based Brake Testing Technologies sponsored by the Federal Highway Administrations (FHWA) Office of Motor Carriers.

  11. 40 CFR 60.58b - Compliance and performance testing.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... monitored and record the output of the system and shall comply with the test procedures and test methods....1.1 (relative accuracy test audit) shall apply to the monitor. (6) If carbon dioxide is selected for... established during the initial performance test according to the procedures and methods specified in...

  12. 40 CFR 60.58b - Compliance and performance testing.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... monitored and record the output of the system and shall comply with the test procedures and test methods....1.1 (relative accuracy test audit) shall apply to the monitor. (6) If carbon dioxide is selected for... established during the initial performance test according to the procedures and methods specified in...

  13. 40 CFR 60.58b - Compliance and performance testing.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... monitored and record the output of the system and shall comply with the test procedures and test methods....1.1 (relative accuracy test audit) shall apply to the monitor. (6) If carbon dioxide is selected for... established during the initial performance test according to the procedures and methods specified in...

  14. Performance testing of supercapacitors: Important issues and uncertainties

    NASA Astrophysics Data System (ADS)

    Zhao, Jingyuan; Gao, Yinghan; Burke, Andrew F.

    2017-09-01

    Supercapacitors are a promising technology for high power energy storage, which have been used in some industrial and vehicles applications. Hence, it is important that information concerning the performance of supercapacitors be detailed and reliable so system designers can make rational decisions regarding the selection of the energy storage components. This paper is concerned with important issues and uncertainties regarding the performance testing of supercapacitors. The effect of different test procedures on the measured characteristics of both commercial and prototype supercapacitors including hybrid supercapacitors have been studied. It was found that the test procedure has a relatively minor effect on the capacitance of carbon/carbon devices and a more significant effect on the capacitance of hybrid supercapacitors. The device characteristic with the greatest uncertainty is the resistance and subsequently the claimed power capability of the device. The energy density should be measured by performing constant power discharges between appropriate voltage limits. This is particularly important in the case of hybrid supercapacitors for which the energy density is rate dependent and the simple relationship E = ½CV2 does not yield accurate estimates of the energy stored. In general, most of the important issues for testing carbon/carbon devices become more serious for hybrid supercapacitors.

  15. Further examination of embedded performance validity indicators for the Conners' Continuous Performance Test and Brief Test of Attention in a large outpatient clinical sample.

    PubMed

    Sharland, Michael J; Waring, Stephen C; Johnson, Brian P; Taran, Allise M; Rusin, Travis A; Pattock, Andrew M; Palcher, Jeanette A

    2018-01-01

    Assessing test performance validity is a standard clinical practice and although studies have examined the utility of cognitive/memory measures, few have examined attention measures as indicators of performance validity beyond the Reliable Digit Span. The current study further investigates the classification probability of embedded Performance Validity Tests (PVTs) within the Brief Test of Attention (BTA) and the Conners' Continuous Performance Test (CPT-II), in a large clinical sample. This was a retrospective study of 615 patients consecutively referred for comprehensive outpatient neuropsychological evaluation. Non-credible performance was defined two ways: failure on one or more PVTs and failure on two or more PVTs. Classification probability of the BTA and CPT-II into non-credible groups was assessed. Sensitivity, specificity, positive predictive value, and negative predictive value were derived to identify clinically relevant cut-off scores. When using failure on two or more PVTs as the indicator for non-credible responding compared to failure on one or more PVTs, highest classification probability, or area under the curve (AUC), was achieved by the BTA (AUC = .87 vs. .79). CPT-II Omission, Commission, and Total Errors exhibited higher classification probability as well. Overall, these findings corroborate previous findings, extending them to a large clinical sample. BTA and CPT-II are useful embedded performance validity indicators within a clinical battery but should not be used in isolation without other performance validity indicators.

  16. Performance testing of radiobioassay laboratories: In vivo measurements, Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacLellan, J.A.; Traub, R.J.; Olsen, P.C.

    1990-04-01

    A study of two rounds of in vivo laboratory performance testing was undertaken by Pacific Northwest Laboratory (PNL) to determine the appropriateness of the in vivo performance criteria of draft American National Standards Institute (ANSI) standard ANSI N13.3, Performance Criteria for Bioassay.'' The draft standard provides guidance to in vivo counting facilities regarding the sensitivity, precision, and accuracy of measurements for certain categories of commonly assayed radionuclides and critical regions of the body. This report concludes the testing program by presenting the results of the Round Two testing. Testing involved two types of measurements: chest counting for radionuclide detection inmore » the lung, and whole body counting for detection of uniformly distributed material. Each type of measurement was further divided into radionuclide categories as defined in the draft standard. The appropriateness of the draft standard criteria by measuring a laboratory's ability to attain them were judged by the results of both round One and Round Two testing. The testing determined that performance criteria are set at attainable levels, and the majority of in vivo monitoring facilities passed the criteria when complete results were submitted. 18 refs., 18 figs., 15 tabs.« less

  17. Orion Exploration Flight Test-1 Post-Flight Navigation Performance Assessment Relative to the Best Estimated Trajectory

    NASA Technical Reports Server (NTRS)

    Gay, Robert S.; Holt, Greg N.; Zanetti, Renato

    2016-01-01

    This paper details the post-flight navigation performance assessment of the Orion Exploration Flight Test-1 (EFT-1). Results of each flight phase are presented: Ground Align, Ascent, Orbit, and Entry Descent and Landing. This study examines the on-board Kalman Filter uncertainty along with state deviations relative to the Best Estimated Trajectory (BET). Overall the results show that the Orion Navigation System performed as well or better than expected. Specifically, the Global Positioning System (GPS) measurement availability was significantly better than anticipated at high altitudes. In addition, attitude estimation via processing GPS measurements along with Inertial Measurement Unit (IMU) data performed very well and maintained good attitude throughout the mission.

  18. Performance Test for the SIGMA Communication System

    NASA Astrophysics Data System (ADS)

    Jeong, Seonyeong; Lee, Hyojeong; Lee, Seongwhan; Shin, Jehyuck; Lee, Jungkyu; Jin, Ho

    2016-12-01

    Scientific CubeSat with Instruments for Global Magnetic Fields and Radiations (SIGMA) is a 3-U size CubeSat that will be operated in low earth orbit (LEO). The SIGMA communication system uses a very high frequency (VHF) band for uplink and an ultra high frequency (UHF) band for downlink. Both frequencies belong to an amateur band. The ground station that communicates with SIGMA is located at Kyung Hee Astronomical Observatory (KHAO). For reliable communication, we carried out a laboratory (LAB) test and far-field tests between the CubeSat and a ground station. In the field test, we considered test parameters such as attenuation, antenna deployment, CubeSat body attitude, and Doppler frequency shift in transmitting commands and receiving data. In this paper, we present a communication performance test of SIGMA, a link budget analysis, and a field test process. We also compare the link budget with the field test results of transmitting commands and receiving data.

  19. DECIDE: a software for computer-assisted evaluation of diagnostic test performance.

    PubMed

    Chiecchio, A; Bo, A; Manzone, P; Giglioli, F

    1993-05-01

    The evaluation of the performance of clinical tests is a complex problem involving different steps and many statistical tools, not always structured in an organic and rational system. This paper presents a software which provides an organic system of statistical tools helping evaluation of clinical test performance. The program allows (a) the building and the organization of a working database, (b) the selection of the minimal set of tests with the maximum information content, (c) the search of the model best fitting the distribution of the test values, (d) the selection of optimal diagnostic cut-off value of the test for every positive/negative situation, (e) the evaluation of performance of the combinations of correlated and uncorrelated tests. The uncertainty associated with all the variables involved is evaluated. The program works in a MS-DOS environment with EGA or higher performing graphic card.

  20. Fan Noise Source Diagnostic Test: Rotor Alone Aerodynamic Performance Results

    NASA Technical Reports Server (NTRS)

    Hughes, Christopher E.; Jeracki, Robert J.; Woodward, Richard P.; Miller, Christopher J.

    2005-01-01

    The aerodynamic performance of an isolated fan or rotor alone model was measured in the NASA Glenn Research Center 9- by 15- Foot Low Speed Wind Tunnel as part of the Fan Broadband Source Diagnostic Test conducted at NASA Glenn. The Source Diagnostic Test was conducted to identify the noise sources within a wind tunnel scale model of a turbofan engine and quantify their contribution to the overall system noise level. The fan was part of a 1/5th scale model representation of the bypass stage of a current technology turbofan engine. For the rotor alone testing, the fan and nacelle, including the inlet, external cowl, and fixed area fan exit nozzle, were modeled in the test hardware; the internal outlet guide vanes located behind the fan were removed. Without the outlet guide vanes, the velocity at the nozzle exit changes significantly, thereby affecting the fan performance. As part of the investigation, variations in the fan nozzle area were tested in order to match as closely as possible the rotor alone performance with the fan performance obtained with the outlet guide vanes installed. The fan operating performance was determined using fixed pressure/temperature combination rakes and the corrected weight flow. The performance results indicate that a suitable nozzle exit was achieved to be able to closely match the rotor alone and fan/outlet guide vane configuration performance on the sea level operating line. A small shift in the slope of the sea level operating line was measured, which resulted in a slightly higher rotor alone fan pressure ratio at take-off conditions, matched fan performance at cutback conditions, and a slightly lower rotor alone fan pressure ratio at approach conditions. However, the small differences in fan performance at all fan conditions were considered too small to affect the fan acoustic performance.

  1. Stereotype threat? Effects of inquiring about test takers' gender on conceptual test performance in physics

    NASA Astrophysics Data System (ADS)

    Maries, Alexandru; Singh, Chandralekha

    2015-12-01

    It has been found that activation of a stereotype, for example by indicating one's gender before a test, typically alters performance in a way consistent with the stereotype, an effect called "stereotype threat." On a standardized conceptual physics assessment, we found that asking test takers to indicate their gender right before taking the test did not deteriorate performance compared to an equivalent group who did not provide gender information. Although a statistically significant gender gap was present on the standardized test whether or not students indicated their gender, no gender gap was observed on the multiple-choice final exam students took, which included both quantitative and conceptual questions on similar topics.

  2. Application and testing of additive manufacturing for mirrors and precision structures

    NASA Astrophysics Data System (ADS)

    Sweeney, Michael; Acreman, Martyn; Vettese, Tom; Myatt, Ray; Thompson, Mike

    2015-09-01

    Additive Manufacturing (aka AM, and 3-D printing) is widely touted in the media as the foundation for the next industrial revolution. Beneath the hype, AM does indeed offer profound advantages in lead-time, dramatically reduced consumption of expensive raw materials, while enabling new and innovative design forms that cannot be produced by other means. General Dynamics and their industry partners have begun to embrace this technology for mirrors and precision structures used in the aerospace, defense, and precision optical instrumentation industries. Aggressively lightweighted, open and closed back test mirror designs, 75-150 mm in size, were first produced by AM from several different materials. Subsequent optical finishing and test experiments have exceeded expectations for density, surface finish, dimensional stability and isotropy of thermal expansion on the optical scale of measurement. Materials currently under examination include aluminum, titanium, beryllium, aluminum beryllium, Inconel 625, stainless steel/bronze, and PEKK polymer.

  3. Performance norms for a rhesus monkey neuropsychological testing battery: acquisition and long-term performance.

    PubMed

    Weed, M R; Taffe, M A; Polis, I; Roberts, A C; Robbins, T W; Koob, G F; Bloom, F E; Gold, L H

    1999-10-25

    A computerized behavioral battery based upon human neuropsychological tests (CANTAB, CeNeS, Cambridge, UK) has been developed to assess cognitive behaviors of rhesus monkeys. Monkeys reliably performed multiple tasks, providing long-term assessment of changes in a number of behaviors for a given animal. The overall goal of the test battery is to characterize changes in cognitive behaviors following central nervous system (CNS) manipulations. The battery addresses memory (delayed non-matching to sample, DNMS; spatial working memory, using a self-ordered spatial search task, SOSS), attention (intra-/extra-dimensional shift, ID/ED), motivation (progressive-ratio, PR), reaction time (RT) and motor coordination (bimanual task). As with human neuropsychological batteries, different tasks are thought to involve different neural substrates, and therefore performance profiles should assess function in particular brain regions. Monkeys were tested in transport cages, and responding on a touch sensitive computer monitor was maintained by food reinforcement. Parametric manipulations of several tasks demonstrated the sensitivity of performance to increases in task difficulty. Furthermore, the factors influencing difficulty for rhesus monkeys were the same as those shown to affect human performance. Data from this study represent performance of a population of healthy normal monkeys that will be used for comparison in subsequent studies of performance following CNS manipulations such as infection with simian immunodeficiency virus (NeuroAIDS) or drug administration.

  4. Thruster endurance test

    NASA Technical Reports Server (NTRS)

    Collett, C.

    1976-01-01

    A test system was built and several short term tests were completed. The test system included, in addition to the 30-cm ion thruster, a console for powering the thruster and monitoring performance, a vacuum facility for simulating a space environment, and a storage and feed system for the thruster propellant. This system was used to perform three short term tests (one 100-hour and two 500-hour tests), an 1108-hour endurance test which was aborted by a vacuum facility failure, and finally the 10,000-hour endurance test. In addition to the two 400 series thrusters which were used in the short term and 1100-hour tests, four more 400 series thrusters were fabricated, checked out, and delivered to NASA. Three consoles similar to the one used in the test program were also fabricated and delivered.

  5. Enhancement on Wingate Anaerobic Test Performance With Hyperventilation.

    PubMed

    Leithäuser, Renate M; Böning, Dieter; Hütler, Matthias; Beneke, Ralph

    2016-07-01

    Relatively long-lasting metabolic alkalizing procedures such as bicarbonate ingestion have potential for improving performance in long-sprint to middle-distance events. Within a few minutes, hyperventilation can induce respiratory alkalosis. However, corresponding performance effects are missing or equivocal at best. To test a potential performance-enhancing effect of respiratory alkalosis in a 30-s Wingate Anaerobic Test (WAnT). 10 men (mean ± SD age 26.6 ± 4.9 y, height 184.4 ± 6.1 cm, body-mass test 1 80.7 ± 7.7 kg, body-mass test 2 80.4 ± 7.2 kg, peak oxygen uptake 3.95 ± 0.43 L/min) performed 2 WAnTs, 1 with and 1 without a standardized 15-min hyperventilation program pre-WAnT in randomized order separated by 1 wk. Compared with the control condition, hyperventilation reduced (all P < .01) pCO2 (40.5 ± 2.8 vs 22.5 ± 1.6 mm Hg) and HCO3 - (25.5 ± 1.7 vs 22.7 ± 1.6 mmol/L) and increased (all P < .01) pH (7.41 ± 0.01 vs 7.61 ± 0.03) and actual base excess (1.4 ± 1.4 vs 3.2 ± 1.6 mmol/L) pre-WAnT with an ergogenic effect on WAnT average power (681 ± 41 vs 714 ± 44 W) and total metabolic energy (138 ± 12 vs. 144 ± 13 kJ) based on an increase in glycolytic energy (81 ± 13 vs 88 ± 13 kJ). Hyperventilation-induced respiratory alkalosis can enhance WAnT cycling sprint performance well in the magnitude of what is seen after successful bicarbonate ingestion.

  6. 40 CFR 63.5992 - When must I conduct subsequent performance tests?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... performance tests? 63.5992 Section 63.5992 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... CATEGORIES National Emissions Standards for Hazardous Air Pollutants: Rubber Tire Manufacturing General Testing and Initial Compliance Requirements § 63.5992 When must I conduct subsequent performance tests? If...

  7. Guidelines for cone penetration test : performance and design

    DOT National Transportation Integrated Search

    1978-07-01

    This manual presents procedures and guidelines applicable to the use of the cone penetration test. Dr. Schmertmann prepared this manual in February 1977 and made minor additions in May 1978. It represents his interpretation of the state-of-the-art in...

  8. 76 FR 65382 - Regulation of Fuel and Fuel Additives: Alternative Test Method for Olefins in Gasoline

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-21

    ... Regulation of Fuel and Fuel Additives: Alternative Test Method for Olefins in Gasoline AGENCY: Environmental... gasoline. This final rule will provide flexibility to the regulated community by allowing an additional... Method for Olefins in Gasoline III. Statutory and Executive Order Reviews A. Executive Order 12866...

  9. Honeywell Cascade Distiller System Performance Testing Interim Results

    NASA Technical Reports Server (NTRS)

    Callahan, Michael R.; Sargusingh, Miriam

    2014-01-01

    The ability to recover and purify water through physiochemical processes is crucial for realizing long-term human space missions, including both planetary habitation and space travel. Because of their robust nature, distillation systems have been actively pursued as one of the technologies for water recovery. The Cascade Distillation System (CDS) is a vacuum rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. The CDS was previously under development through Honeywell and NASA. In 2009, an assessment was performed to collect data to support down-selection and development of a primary distillation technology for application in a lunar outpost water recovery system. Based on the results of this testing, an expert panel concluded that the CDS showed adequate development maturity, TRL-4, together with the best product water quality and competitive weight and power estimates to warrant further development. The Advanced Exploration Systems (AES) Water Recovery Project (WRP) worked to address weaknesses identified by The Panel; namely bearing design and heat pump power efficiency. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades. The CDS will also have been challenged with ISS analog waste streams and a subset of those being considered for Exploration architectures. This paper details interim results of the AES WRP CDS performance testing.

  10. Performance and durability testing of parabolic trough receivers

    NASA Astrophysics Data System (ADS)

    Lei, Dongqiang; Fu, Xuqiang; Zhao, Dongming; Yuan, Guofeng; Wang, Zhifeng; Guo, Minghuan

    2017-06-01

    The paper describes the key performance and durability testing facilities of the parabolic trough receiver developed by Institute of Electrical Engineering, Chinese Academy of Sciences. The indoor heat loss test can be applied at 4-7 different temperature levels within 200-550 on receivers. The optical efficiency test bench consists of 12 metal halide lamps as the solar simulator and a 5 m length half-elliptical cylinder reflector with flat end reflectors. 3 ultra-precision temperature sensors are used in receiver each end to get the temperature difference. The residual gas analysis test bench is applied to analyze and predict the vacuum lifetime of the receiver. It can test the variations of composition and partial pressure of residual gases with temperature and time in the receiver annulus space by a high sensitivity quadrupole mass spectrometer gas analyzer. A coating accelerated ageing test bench, which is also used to test the thermal cycle, has been developed. This test bench uses the absorber tube of the recevier as the resistance heater to heat up the whole receiver. The coating lifetime can be predicted by the Arrhenius parameters. For the cycling test, the compressed air is used to directly cool the inner surface of the absorber tube. The thermal cycling test is performed with temperature cycles from 150 °C to 450 °C for 160 cycles. The maximum thermal cycling frequency is 8 cycles per day. The mechanical fatigue test bench is used to test the bellows and the glass-to-metal seals durability at the same time. Both bellows are expanded and compressed to 6.5 mm in turn with 10,000 cycles. A new rotating test bench was also developed to test the thermal efficiency of the receiver.

  11. Evaluation of Asphalt Mixture Low-Temperature Performance in Bending Beam Creep Test.

    PubMed

    Pszczola, Marek; Jaczewski, Mariusz; Rys, Dawid; Jaskula, Piotr; Szydlowski, Cezary

    2018-01-10

    Low-temperature cracking is one of the most common road pavement distress types in Poland. While bitumen performance can be evaluated in detail using bending beam rheometer (BBR) or dynamic shear rheometer (DSR) tests, none of the normalized test methods gives a comprehensive representation of low-temperature performance of the asphalt mixtures. This article presents the Bending Beam Creep test performed at temperatures from -20 °C to +10 °C in order to evaluate the low-temperature performance of asphalt mixtures. Both validation of the method and its utilization for the assessment of eight types of wearing courses commonly used in Poland were described. The performed test indicated that the source of bitumen and its production process (and not necessarily only bitumen penetration) had a significant impact on the low-temperature performance of the asphalt mixtures, comparable to the impact of binder modification (neat, polymer-modified, highly modified) and the aggregate skeleton used in the mixture (Stone Mastic Asphalt (SMA) vs. Asphalt Concrete (AC)). Obtained Bending Beam Creep test results were compared with the BBR bitumen test. Regression analysis confirmed that performing solely bitumen tests is insufficient for comprehensive low-temperature performance analysis.

  12. Evaluation of Asphalt Mixture Low-Temperature Performance in Bending Beam Creep Test

    PubMed Central

    Rys, Dawid; Jaskula, Piotr; Szydlowski, Cezary

    2018-01-01

    Low-temperature cracking is one of the most common road pavement distress types in Poland. While bitumen performance can be evaluated in detail using bending beam rheometer (BBR) or dynamic shear rheometer (DSR) tests, none of the normalized test methods gives a comprehensive representation of low-temperature performance of the asphalt mixtures. This article presents the Bending Beam Creep test performed at temperatures from −20 °C to +10 °C in order to evaluate the low-temperature performance of asphalt mixtures. Both validation of the method and its utilization for the assessment of eight types of wearing courses commonly used in Poland were described. The performed test indicated that the source of bitumen and its production process (and not necessarily only bitumen penetration) had a significant impact on the low-temperature performance of the asphalt mixtures, comparable to the impact of binder modification (neat, polymer-modified, highly modified) and the aggregate skeleton used in the mixture (Stone Mastic Asphalt (SMA) vs. Asphalt Concrete (AC)). Obtained Bending Beam Creep test results were compared with the BBR bitumen test. Regression analysis confirmed that performing solely bitumen tests is insufficient for comprehensive low-temperature performance analysis. PMID:29320443

  13. The paced auditory serial addition test for working memory assessment: Psychometric properties

    PubMed Central

    Nikravesh, Maryam; Jafari, Zahra; Mehrpour, Masoud; Kazemi, Roozbeh; Amiri Shavaki, Younes; Hossienifar, Shamim; Azizi, Mohamad Parsa

    2017-01-01

    Background: The paced auditory serial addition test (PASAT) was primarily developed to assess the effects of traumatic brain injury on cognitive functioning. Working memory (WM) is one of the most important aspects of cognitive function, and WM impairment is one of the clinically remarkable signs of aphasia. To develop the Persian version of PASAT, an initial version was used in individuals with aphasia (IWA). Methods: In this study, 25 individuals with aphasia (29-60 years) and 85 controls (18-60 years) were included. PASAT was presented in the form of recorded 61 single-digit numbers (1 to 9). The participants repeatedly added the 2 recent digits. The psychometric properties of PASAT including convergent validity (using the digit memory span tasks), divergent validity (using results in the control group and IWA group), and face validity were investigated. Test-retest reliability was considered as well. Results: The relationship between the PASAT and digit memory span tests was moderate to strong in the control group (forward digit memory span test: r= 0.52, p< 0.0001; backward digit memory span test: r = 0.48, p< 0.0001). A strong relationship was found in IWA (forward digit memory span test: r= 0.72, p< 0.0001; backward digit memory span test: r= 0.53, p= 0.006). Also, strong testretest reliability (intraclass correlation= 0.95, p< 0.0001) was observed. Conclusion: According to our results, the PASAT is a valid and reliable test to assess working memory, particularly in IWA. It could be used as a feasible tool for clinical and research applications. PMID:29445690

  14. A generalized correlation of experimental flat-plate collector performance. [solar collectors, performance tests, energy policy

    NASA Technical Reports Server (NTRS)

    Simon, F. F.; Miller, D. R.

    1975-01-01

    A generalized collector performance correlation was derived and shown by experimental verification to be of the proper form to account for the majority of the variable conditions encountered both in outdoor and in indoor collector tests. This correlation permits a determination of collector parameters which are essentially nonvarying under conditions which do vary randomly (outdoors) or conditions which vary in a controlled manner (indoors - simulator). It was shown that correlation of the experimental performance of collectors allows the following: (1) comparisons of different collector designs; (2) collector performance prediction under conditions that differ from the conditions of the test program; and (3) monitoring performance degradation effects.

  15. Functional Performance and Associations between Performance Tests and Neurological Assessment Differ in Men and Women with Parkinson's Disease.

    PubMed

    Medijainen, Kadri; Pääsuke, Mati; Lukmann, Aet; Taba, Pille

    2015-01-01

    Neurological assessment of a patient with Parkinson's disease (PD) is expected to reflect upon functional performance. As women are known to report more limitations even for same observed functional performance level, present study was designed to examine whether associations between neurological assessments and functional performance differ across genders. 14 men and 14 women with PD participated. Functional performance was assessed by measuring walking speeds on 10-meter walk test (10MWT) and by performing timed-up-and-go-test (TUG). Neurological assessment included Hoehn and Yahr Scale (HY), Movement Disorders Society Unified Parkinson's Disease Rating Scale (MDS-UPDRS), Schwab and England Activities of Daily Living Scale (S-E), and Mini Mental State Examination (MMSE). In women with PD, Kendall's tau-b correlation analyses revealed significant correlations between functional performance tests and neurological assessment measures, with the exception in MMSE. No corresponding associations were found for men, although they demonstrated better functional performance, as expected. Men in similar clinical stage of the PD perform better on functional tests than women. Disease severity reflects upon functional performance differently in men and women with PD. Results indicate that when interpreting the assessment results of both functional performance and neurological assessment tests, the gender of the patient should be taken into consideration.

  16. Relationship between performance test and body composition/physical strength characteristic in sprint canoe and kayak paddlers

    PubMed Central

    Hamano, Saki; Ochi, Eisuke; Tsuchiya, Yosuke; Muramatsu, Erina; Suzukawa, Kazuhiro; Igawa, Shoji

    2015-01-01

    Objective Canoe sprint is divided into canoe and kayak. The difference between the two competitions is in physical performance. The aim of the present study was to compare and investigate the relationship between physical characteristics and fitness between the two canoe sprint competitors. Methods Subjects were 11 canoe paddlers (C) and 12 kayak paddlers (K). They underwent anthropometric characteristics, body composition and fitness tests, and 120 s all-out tests using a canoe and kayak ergometer. The unpaired t-test was used to test for significant differences between disciplines, while Pearson’s correlation coefficient was used to examine the association between each measurement item and the performance test. Results The age, height, body mass, body mass index, and total body fat were, C: 20.6±0.9 yr, 172.8±5.2 cm, 70.8±7.8 kg, 23.7±1.9, 14.4%±3.5%; and K: 19.7±1.2 yr, 172.8±5.3 cm, 69.5±7.8 kg, 23.2±2.1, 12.1%±3.6%, respectively. No significant differences were seen in any of the items for physical characteristics or fitness between C and K. A correlation analysis of performance tests and each measurement item revealed a positive correlation with low-speed isokinetic knee extension and flexion strength for C only (extension: r=0.761; flexion: r=0.784; P<0.01). In addition, performance tests were positively correlated with the circumference of arm (upper arm: r=0.876; forearm: r=0.820; P<0.01) and lower limb (thigh: r=0.781; calf: r=0.753; P<0.01) in C and with height (r=0.549, P<0.05), arm span (r=0.639, P<0.05), and leg length (r=0.621, P<0.01) in K. Conclusion We suggest that the factors correlating with the performance test differ depending on the competitions. PMID:26150737

  17. Largo hot water system long range thermal performance test report, addendum

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The test procedure used and the test results obtained during the long range thermal performance tests of the LARGO Solar Hot Water System under natural environmental conditions are presented. Objectives of these tests were to determine the amount of energy collected, the amount of power required for system operation, system efficiency, temperature distribution, and system performance degradation.

  18. Functional Performance Testing After Anterior Cruciate Ligament Reconstruction

    PubMed Central

    Abrams, Geoffrey D.; Harris, Joshua D.; Gupta, Anil K.; McCormick, Frank M.; Bush-Joseph, Charles A.; Verma, Nikhil N.; Cole, Brian J.; Bach, Bernard R.

    2014-01-01

    Background: When to allow an athlete to return to unrestricted sporting activity after anterior cruciate ligament (ACL) reconstruction remains controversial. Purpose: To report the results of functional performance testing reported in the literature for individuals at differing time points following ACL reconstruction and to examine differences between graft types. Study Design: Systematic review; Level of evidence, 4. Methods: A systematic review of Medline, Scopus, and Cochrane Central Register of Controlled Trials was performed using PRISMA guidelines. Inclusion criteria were English-language studies that examined any functional rehabilitation test from 6 months to 2 years following ACL reconstruction. All patient-, limb-, and knee-specific demographics were extracted from included investigations. All functional rehabilitation tests were analyzed and compared when applicable. Results: The search term returned a total of 890 potential studies, with 88 meeting inclusion and exclusion criteria. A total of 4927 patients were included, of which 66% were male. The mean patient age was 26.5 ± 3.4 years. The predominant graft choices for reconstruction were bone–patellar tendon–bone (BPTB) autograft (59.8%) and hamstring autograft (37.9%). The most commonly reported functional tests were the hop tests. The results of these functional tests, as reported in the Limb Symmetry Index (LSI), improved with increasing time, with nearly all results greater than 90% at 1 year following primary ACL reconstruction. At 6 months postoperatively, a number of isokinetic strength measurements failed to reach 80% LSI, most commonly isokinetic knee extension testing in both BPTB and hamstring autograft groups. The knee flexion strength deficit was significantly less in the BPTB autograft group as compared with those having hamstring autograft at 1 year postoperatively, while no significant differences were found in isokinetic extension strength between the 2 groups. Conclusion: Hop

  19. Performance map of a cluster detection test using extended power

    PubMed Central

    2013-01-01

    Background Conventional power studies possess limited ability to assess the performance of cluster detection tests. In particular, they cannot evaluate the accuracy of the cluster location, which is essential in such assessments. Furthermore, they usually estimate power for one or a few particular alternative hypotheses and thus cannot assess performance over an entire region. Takahashi and Tango developed the concept of extended power that indicates both the rate of null hypothesis rejection and the accuracy of the cluster location. We propose a systematic assessment method, using here extended power, to produce a map showing the performance of cluster detection tests over an entire region. Methods To explore the behavior of a cluster detection test on identical cluster types at any possible location, we successively applied four different spatial and epidemiological parameters. These parameters determined four cluster collections, each covering the entire study region. We simulated 1,000 datasets for each cluster and analyzed them with Kulldorff’s spatial scan statistic. From the area under the extended power curve, we constructed a map for each parameter set showing the performance of the test across the entire region. Results Consistent with previous studies, the performance of the spatial scan statistic increased with the baseline incidence of disease, the size of the at-risk population and the strength of the cluster (i.e., the relative risk). Performance was heterogeneous, however, even for very similar clusters (i.e., similar with respect to the aforementioned factors), suggesting the influence of other factors. Conclusions The area under the extended power curve is a single measure of performance and, although needing further exploration, it is suitable to conduct a systematic spatial evaluation of performance. The performance map we propose enables epidemiologists to assess cluster detection tests across an entire study region. PMID:24156765

  20. BAAM Additive Manufacturing of Magnetically Levitated Wind Turbine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richardson, Bradley S.; Noakes, Mark W.; Roschli, Alex C.

    ORNL worked with Hover Energy LLC (Hover) on the design of Big Area Additive Manufacturing (BAAM) extrusion components. The objective of this technical collaboration was to identify and evaluate fabrication of components using alternative additive manufacturing techniques. Multiple candidate parts were identified. A design modification to fabricate diverters using additive manufacturing (AM) was performed and the part was analyzed based on anticipated wind loading. Scaled versions of two parts were printed using the BAAM for wind tunnel testing.

  1. An Evaluation of the Additional Acoustic Power Needed to Overcome the Effects of a Test-Article's Absorption During Reverberant Chamber Acoustic Testing of Spaceflight Hardware

    NASA Technical Reports Server (NTRS)

    Hozman, Aron D.; Hughes, William O.

    2014-01-01

    The exposure of a customer's aerospace test-article to a simulated acoustic launch environment is typically performed in a reverberant acoustic test chamber. The acoustic pre-test runs that will ensure that the sound pressure levels of this environment can indeed be met by a test facility are normally performed without a test-article dynamic simulator of representative acoustic absorption and size. If an acoustic test facility's available acoustic power capability becomes maximized with the test-article installed during the actual test then the customer's environment requirement may become compromised. In order to understand the risk of not achieving the customer's in-tolerance spectrum requirement with the test-article installed, an acoustic power margin evaluation as a function of frequency may be performed by the test facility. The method for this evaluation of acoustic power will be discussed in this paper. This method was recently applied at the NASA Glenn Research Center Plum Brook Station's Reverberant Acoustic Test Facility for the SpaceX Falcon 9 Payload Fairing acoustic test program.

  2. An Evaluation of the Additional Acoustic Power Needed to Overcome the Effects of a Test-Article's Absorption during Reverberant Chamber Acoustic Testing of Spaceflight Hardware

    NASA Technical Reports Server (NTRS)

    Hozman, Aron D.; Hughes, William O.

    2014-01-01

    The exposure of a customers aerospace test-article to a simulated acoustic launch environment is typically performed in a reverberant acoustic test chamber. The acoustic pre-test runs that will ensure that the sound pressure levels of this environment can indeed be met by a test facility are normally performed without a test-article dynamic simulator of representative acoustic absorption and size. If an acoustic test facilitys available acoustic power capability becomes maximized with the test-article installed during the actual test then the customers environment requirement may become compromised. In order to understand the risk of not achieving the customers in-tolerance spectrum requirement with the test-article installed, an acoustic power margin evaluation as a function of frequency may be performed by the test facility. The method for this evaluation of acoustic power will be discussed in this paper. This method was recently applied at the NASA Glenn Research Center Plum Brook Stations Reverberant Acoustic Test Facility for the SpaceX Falcon 9 Payload Fairing acoustic test program.

  3. Does sensitivity measured from screening test-sets predict clinical performance?

    NASA Astrophysics Data System (ADS)

    Soh, BaoLin P.; Lee, Warwick B.; Mello-Thoms, Claudia R.; Tapia, Kriscia A.; Ryan, John; Hung, Wai Tak; Thompson, Graham J.; Heard, Rob; Brennan, Patrick C.

    2014-03-01

    Aim: To examine the relationship between sensitivity measured from the BREAST test-set and clinical performance. Background: Although the UK and Australia national breast screening programs have regarded PERFORMS and BREAST test-set strategies as possible methods of estimating readers' clinical efficacy, the relationship between test-set and real life performance results has never been satisfactorily understood. Methods: Forty-one radiologists from BreastScreen New South Wales participated in this study. Each reader interpreted a BREAST test-set which comprised sixty de-identified mammographic examinations sourced from the BreastScreen Digital Imaging Library. Spearman's rank correlation coefficient was used to compare the sensitivity measured from the BREAST test-set with screen readers' clinical audit data. Results: Results shown statistically significant positive moderate correlations between test-set sensitivity and each of the following metrics: rate of invasive cancer per 10 000 reads (r=0.495; p < 0.01); rate of small invasive cancer per 10 000 reads (r=0.546; p < 0.001); detection rate of all invasive cancers and DCIS per 10 000 reads (r=0.444; p < 0.01). Conclusion: Comparison between sensitivity measured from the BREAST test-set and real life detection rate demonstrated statistically significant positive moderate correlations which validated that such test-set strategies can reflect readers' clinical performance and be used as a quality assurance tool. The strength of correlation demonstrated in this study was higher than previously found by others.

  4. Thermal Performance Testing of EMU and OSS Liquid Cooling Garments

    NASA Technical Reports Server (NTRS)

    Rhodes, Richard; Bue, Grant; Hakam, Mary

    2012-01-01

    A test was conducted to evaluate three factors influencing the thermal performance of liquid cooling garments (LCG): (1) the comparable thermal performance of an Oceaneering developed engineering evaluation unit (EEU) prototype LDG, (2) the effect of the thermal comfort undergarment (TCU), and (3) the performance of a torso or upper body only LCG configuration. To evaluate the thermal performance of each configuration a metabolic test was conducted, utilizing suited subjects to generate the metabolic heat. For this study three (3) test subjects of similar health and weight produced a metabolic load on the LDG configuration by either resting (300-600 BTU/hr), walking at a slow pace (1200 BRU/hr), and walking at a brisk pace (2200 BTU/hr), as outlined in Figure 1, the metabolic profile. During the test, oxygen consumption, heart rate, relative humidity, air flow, inlet and outlet air pressure, inlet and outlet air temperature, delta air temperature, water flow (100 lb/hr), inlet water temperature (64 F), delta water temperature, water pressure, core body temperature, skin temperature, and sweat loss data was recorded. Four different test configurations were tested, with one configuration tested twice, as outlined in Table 1. The test was conducted with the suit subjects wearing the Demonstrator Suit, pressurized to vent pressure (approximately 0.5 psig). The demonstrator suit has an integrated ventilation duct system and was used to create a relevant environment with a captured ventilation return, an integrated vent tree, and thermal insulation from the environment.

  5. SAS molecular tests Escherichia coli O157 detection kit. Performance tested method 031203.

    PubMed

    Bapanpally, Chandra; Montier, Laura; Khan, Shah; Kasra, Akif; Brunelle, Sharon L

    2014-01-01

    The SAS Molecular tests Escherichia coli O157 Detection method, a loop-mediated isothermal amplification method, performed as well as or better than the U.S. Department of Agriculture, Food Safety Inspection Service Microbiology Laboratory Guidebook and the U.S. Food and Drug Administration Bacteriological Analytical Manual reference methods for ground beef, beef trim, bagged mixed lettuce, and fresh spinach. Ground beef (30% fat, 25 g test portion) was validated for 7-8 h enrichment, leafy greens were validated in a 6-7 h enrichment, and ground beef (30% fat, 375 g composite test portion) and beef trim (375 g composite test portion) were validated in a 16-20 h enrichment. The method performance for meat and leafy green matrixes was also shown to be acceptable under conditions of co-enrichment with Salmonella. Thus, after a short co-enrichment step, ground beef, beef trim, lettuce, and spinach can be tested for both Salmonella and E. coli O157. The SAS Molecular tests Salmonella Detection Kit was validated using the same test portions as for the SAS Molecular tests E. coli O157 Detection Kit and those results are presented in a separate report. Inclusivity and exclusivity testing revealed no false negatives and no false positives among the 50 E. coli 0157 strains, including H7 and non-motile strains, and 30 non-E. coli O157 strains examined. Finally, the method was shown to be robust when variations to DNA extract hold time and DNA volume were varied. The method comparison and robustness data suggest a full 7 h enrichment time should be used for 25 g ground beef test portions.

  6. Distraction produces over-additive increases in the degree to which alcohol impairs driving performance

    PubMed Central

    Van Dyke, Nicholas A.; Fillmore, Mark T.

    2015-01-01

    Rationale Research indicates that alcohol intoxication and increased demands on drivers’ attention from distractions (e.g. passengers and cell phones) contribute to poor driving performance and increased rates of traffic accidents and fatalities. Objectives The present study examined the separate and combined effects of alcohol and distraction on simulated driving performance at blood alcohol concentrations (BrACs) below the legal driving limit in the United States (i.e. 0.08%). Methods Fifty healthy adult drivers (36 men and 14 women) were tested in a driving simulator following a 0.65 g/kg dose of alcohol and a placebo. Drivers completed two drive tests; a distracted drive, which included a two-choice detection task, and an undistracted control drive. Multiple indicators of driving performance, such as drive speed, within-lane deviation, steering rate, and lane exceedances were measured. Results Alcohol and distraction each impaired measures of driving performance. Moreover, the magnitude of alcohol impairment was increased by at least two-fold when tested under the distracting versus the undistracted condition. Conclusions The findings highlight the need for a clearer understanding of how common distractions impact intoxicated drivers, especially at BrACs that are currently legal for driving in the United States. PMID:26349918

  7. 40 CFR Table 6 to Subpart Wwww of... - Basic Requirements for Performance Tests, Performance Evaluations, and Design Evaluations for New...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Performance Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and...

  8. 40 CFR Table 6 to Subpart Wwww of... - Basic Requirements for Performance Tests, Performance Evaluations, and Design Evaluations for New...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Performance Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and...

  9. 40 CFR Table 6 to Subpart Wwww of... - Basic Requirements for Performance Tests, Performance Evaluations, and Design Evaluations for New...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Performance Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and...

  10. Performance of cellulose acetate membrane with different additives for palm oil mill effluent (POME) liquid waste treatment

    NASA Astrophysics Data System (ADS)

    Aprilia, N. A. S.; Fauzi; Azmi, N.; Najwan, N.; Amin, A.

    2018-03-01

    Performance of cellulose acetate membrane for treatment of POME liquid has studied with different additives. Cellulose acetate membranes were prepared with different additive ie formamide and polyethylene glycol and used acetone as solvent. The function of formamide and polyethylene glycol (PEG) is to increase the porosity of the membrane surface. Performance of the membrane were included SEM, FT-IR and coefficient permeability. Membrane performance has been performed for percent rejection of total suspended solid (TSS) and turbidity of POME liquid waste. Cellulose acetate with formamide shows an increased percentage of rejection in removing TSS and turbidity than cellulose acetate with PEG.

  11. Physical performance testing in mucopolysaccharidosis I: a pilot study.

    PubMed

    Dumas, Helene M; Fragala, Maria A; Haley, Stephen M; Skrinar, Alison M; Wraith, James E; Cox, Gerald F

    2004-01-01

    To develop and field-test a physical performance measure (MPS-PPM) for individuals with Mucopolysaccharidosis I (MPS I), a rare genetic disorder. Motor performance and endurance items were developed based on literature review, clinician feedback, feasibility, and equipment and training needs. A standardized testing protocol and scoring rules were created. The MPS-PPM includes: Arm Function (7 items), Leg Function (5 items), and Endurance (2 items). Pilot data were collected for 10 subjects (ages 5-29 years). We calculated Spearman's rho correlations between age, severity and summary z-scores on the MPS-PPM. Subjects had variable presentations, as correlations among the three sub-test scores were not significant. Increasing age was related to greater severity in physical performance (r = 0.72, p<0.05) and lower scores on the Leg Function (r = -0.67, p<0.05) and Endurance (r = -0.65, p<0.05) sub-tests. The MPS-PPM was sensitive to detecting physical performance deficits, as six subjects could not complete the full battery of Arm Function items and eight subjects were unable to complete all Leg Function items. Subjects walked more slowly and expended more energy than typically developing peers. Individuals with MPS I have difficulty with arm and leg function and reduced endurance. The MPS-PPM is a clinically feasible measure that detects limitations in physical performance and may have potential to quantify changes in function following intervention. Copyright 2004 Taylor and Francis Ltd.

  12. 42 CFR 84.103 - Man tests; performance requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man tests; performance requirements. 84.103 Section 84.103 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.103 Man tests;...

  13. 40 CFR 62.14680 - May I conduct performance testing less often?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...

  14. 40 CFR 62.14680 - May I conduct performance testing less often?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...

  15. 40 CFR 62.14680 - May I conduct performance testing less often?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...

  16. 40 CFR 62.14680 - May I conduct performance testing less often?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...

  17. 40 CFR 62.14680 - May I conduct performance testing less often?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...

  18. 40 CFR 60.255 - Performance tests and other compliance requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Preparation and Processing Plants § 60.255 Performance tests and other compliance requirements. (a) An owner... within a 60-minute period of) PM performance tests. (c) If any affected coal processing and conveying...) when the coal preparation and processing plant is in operation. Each observation must be recorded as...

  19. 40 CFR 60.255 - Performance tests and other compliance requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Preparation and Processing Plants § 60.255 Performance tests and other compliance requirements. (a) An owner... within a 60-minute period of) PM performance tests. (c) If any affected coal processing and conveying...) when the coal preparation and processing plant is in operation. Each observation must be recorded as...

  20. 40 CFR 60.255 - Performance tests and other compliance requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Preparation and Processing Plants § 60.255 Performance tests and other compliance requirements. (a) An owner... within a 60-minute period of) PM performance tests. (c) If any affected coal processing and conveying...) when the coal preparation and processing plant is in operation. Each observation must be recorded as...